WorldWideScience

Sample records for hip fractures fixation

  1. sign hip construct: achieving hip fracture fixation without using an ...

    African Journals Online (AJOL)

    Objective: The aim of this study was to assess outcomes of using the SIGN Hip Construct (SHC) to achieve ... The majority (76%) of patients were ambulatory within. 3 days after the surgery. ... Conclusion: Using the SIGN Hip Construct, hip fracture fixation can be ... elderly has made stable reduction and internal fixation.

  2. Total hip arthroplasty following failed fixation of proximal hip fractures

    Directory of Open Access Journals (Sweden)

    Srivastav Shekhar

    2008-01-01

    Full Text Available Background: Most proximal femoral fractures are successfully treated with internal fixation but a failed surgery can be very distressing for the patient due to pain and disability. For the treating surgeon it can be a challenge to perform salvage operations. The purpose of this study was to evaluate the short-term functional outcome and complications of total hip arthroplasty (THA following failed fixation of proximal hip fracture. Materials and Methods: In a retrospective study, 21 hips in 20 patients (13 females and seven males with complications of operated hip fractures as indicated by either established nonunion or fracture collapse with hardware failure were analysed. Mean age of the patients was 62 years (range 38 years to 85 years. Nine patients were treated for femoral neck fracture, 10 for intertrochanteric (I/T fracture and two for subtrochanteric (S/T fracture of the hip. Uncemented THA was done in 11 cases, cemented THA in eight hip joints and hybrid THA in two patients. Results: The average duration of follow-up was four years (2-13 years. The mean duration of surgery was 125 min and blood loss was 1300 ml. There were three dislocations postoperatively. Two were managed conservatively and one was operated. There was one superficial infection and one deep infection. Only one patient required a walker while four required walking stick for ambulation. The mean Harris Hip score increased from 32 preoperatively to 79 postoperatively at one year interval. Conclusion: Total hip arthroplasty is an effective salvage procedure after failed osteosynthesis of hip fractures. Most patients have good pain relief and functional improvements inspite of technical difficulties and high complication rates than primary arthroplasty.

  3. Osteoporotic Hip Fractures: The Burden of Fixation Failure

    Directory of Open Access Journals (Sweden)

    J. M. Broderick

    2013-01-01

    Full Text Available Osteoporotic hip fractures are a major cause of morbidity and mortality in the elderly. Furthermore, reduced implant anchorage in osteoporotic bone predisposes towards fixation failure and with an ageing population, even low failure rates represent a significant challenge to healthcare systems. Fixation failure in fragility fractures of the hip ranges from 5% in peritrochanteric fractures through to 15% and 41% in undisplaced and displaced fractures of the femoral neck, respectively. Our findings, in general, support the view that failed internal fixation of these fragility fractures carries a poor prognosis: it leads to a twofold increase in the length of hospital stay and a doubling of healthcare costs. Patients are more likely to suffer a downgrade in their residential status upon discharge with a consequent increase in social dependency. Furthermore, the marked disability and reduction in quality of life evident before salvage procedures may persist at long-term followup. The risk, of course, for the elderly patient with a prolonged period of decreased functioning is that the disability becomes permanent. Despite this, however, no clear link between revision surgery and an increase in mortality has been demonstrated in the literature.

  4. Osteoporotic hip fractures: the burden of fixation failure.

    Science.gov (United States)

    Broderick, J M; Bruce-Brand, R; Stanley, E; Mulhall, K J

    2013-01-01

    Osteoporotic hip fractures are a major cause of morbidity and mortality in the elderly. Furthermore, reduced implant anchorage in osteoporotic bone predisposes towards fixation failure and with an ageing population, even low failure rates represent a significant challenge to healthcare systems. Fixation failure in fragility fractures of the hip ranges from 5% in peritrochanteric fractures through to 15% and 41% in undisplaced and displaced fractures of the femoral neck, respectively. Our findings, in general, support the view that failed internal fixation of these fragility fractures carries a poor prognosis: it leads to a twofold increase in the length of hospital stay and a doubling of healthcare costs. Patients are more likely to suffer a downgrade in their residential status upon discharge with a consequent increase in social dependency. Furthermore, the marked disability and reduction in quality of life evident before salvage procedures may persist at long-term followup. The risk, of course, for the elderly patient with a prolonged period of decreased functioning is that the disability becomes permanent. Despite this, however, no clear link between revision surgery and an increase in mortality has been demonstrated in the literature.

  5. Fixation of a Periprosthetic Intertrochanteric Hip Fracture below a Birmingham Hip Resurfacing

    Directory of Open Access Journals (Sweden)

    J. Macdonald

    2014-01-01

    Full Text Available This case report involves a 56-year-old female (Mrs X with a traumatic intertrochanteric hip fracture with subtrochanteric extension below a previous Birmingham hip resurfacing. Periprosthetic fractures following hip resurfacing are usually subcapital and treated with a revision or conservative management. We present an unusual surgical problem with an interesting solution stabilising the fracture using a proximal femoral locking compression plate (LCP. Eight months following surgery the patient is able to walk pain free and there is good fixation and stability.

  6. Intraoperative Hypothermia During Surgical Fixation of Hip Fractures.

    Science.gov (United States)

    Frisch, Nicholas B; Pepper, Andrew M; Jildeh, Toufic R; Shaw, Jonathan; Guthrie, Trent; Silverton, Craig

    2016-11-01

    Hip fractures are common orthopedic injuries and are associated with significant morbidity/mortality. Intraoperative normothermia is recommended by national guidelines to minimize additional morbidity/mortality, but limited evidence exists regarding hypothermia's effect on orthopedic patients. The purpose of this study was to determine the incidence of intraoperative hypothermia in patients with operatively treated hip fractures and evaluate its effect on complications and outcomes. Retrospective chart review was performed on clinical records from 1541 consecutive patients who sustained a hip fracture and underwent operative fixation at the authors' institution between January 2005 and October 2013. A total of 1525 patients were included for analysis, excluding those with injuries requiring additional surgical intervention. Patient demographic data, surgery-specific data, postoperative complications, length of stay, and 30-day readmission were recorded. Patients with a mean intraoperative temperature less than 36°C were identified as hypothermic. Statistical analysis with univariate and multivariate logistic regression modeling evaluated associations with hypothermia and effect on complications/outcomes. The incidence of intraoperative hypothermia in operatively treated hip fractures was 17.0%. Hypothermia was associated with an increase in the rate of deep surgical-site infection (odds ratio, 3.30; 95% confidence interval, 1.19-9.14; P=.022). Lower body mass index and increasing age demonstrated increased association with hypothermia (P=.004 and P=.005, respectively). To the authors' knowledge, this is the first and largest study analyzing the effect of intraoperative hypothermia in orthopedic patients. In patients with hip fractures, the study's findings confirm evidence found in other surgical specialties that hypothermia may be associated with an increased risk of deep surgical-site infection and that lower body mass index and increasing age are risk factors

  7. Pseudoaneurysm of profunda femoris artery following dynamic hip screw fixation for intertrochanteric femoral fracture

    Institute of Scientific and Technical Information of China (English)

    Shailendra Singh; Sumit Arora; Ankit Thora; Ram Mohan; Sumit Sural; Anil Dhal

    2013-01-01

    Dynamic hip screw fixation is a commonly performed procedure for internal fixation of intertrochanteric femoral fractures.Arterial injury following the operative fixation is a rare but serious event.We present a patient who developed pseudoaneurysm of profunda femoris artery after internal fixation of intertrochanteric fracture with a dynamic hip screw.The diagnosis was confirmed by angiographic study and it was successfully treated by coil embolization.

  8. Intramedullary fixation of a femoral shaft fracture with preservation of an existing hip resurfacing prosthesis.

    Science.gov (United States)

    Bilkhu, A; Sisodia, G; Chakrabarty, G; Muralikuttan, K P

    2015-04-01

    Femoral neck fractures have been reported as a cause for failure in patients with a hip resurfacing arthroplasty. However, the incidence and management of fractures of the femoral shaft with an ipsilateral hip resurfacing arthroplasty is relatively absent in current literature. Although, the gold standard for the fixation of a closed femoral shaft fracture is with the use of an intramedullary nail, this can be a challenge in the presence of a hip resurfacing arthroplasty. We describe the case of anterograde intramedullary nail fixation for a femoral shaft fracture in a patient with an ipsilateral hip resurfacing arthroplasty in situ.

  9. Clostridium perfringens infection complicating periprosthetic fracture fixation about the hip: successful treatment with early aggressive debridement.

    LENUS (Irish Health Repository)

    Baker, Joseph F

    2012-07-13

    Periprosthetic fracture and infection are both challenges following hip arthroplasty. We report the case of an 87 year old female who underwent open reduction and internal fixation of a periprosthetic femoral fracture. Her post-operative course was complicated by infection with Clostridium perfringens. Early aggressive antibiotic treatment and surgical debridement were successful, and allowed retention of the original components.

  10. Extracapsular hip fractures: fixation with a twin hook or a lag screw?

    Science.gov (United States)

    Olsson, O; Ceder, L; Lunsjö, K; Hauggaard, A

    2000-01-01

    The twin hook, which has 2 oppositely directed apical hooks, is an alternative to the lag screw for use with a 'dynamic plate' in the fixation of trochanteric hip fractures. In this prospective study lasting 1 year, 102 consecutive patients with trochanteric hip fractures were treated by 19 surgeons with either a twin hook or a lag screw combined with a conventional sliding hip screw plate or a Medoff sliding plate. Seven intraoperative errors were made with the twin hook but postoperative migration did not differ significantly between the 2 groups. Postoperative fixation failures were equally distributed between the 2 groups. The twin hook provides adequate fixation, which is comparable to that produced by a lag screw.

  11. Hip Fracture

    Science.gov (United States)

    Diseases and Conditions Hip fracture By Mayo Clinic Staff A hip fracture is a serious injury, with complications that can be life-threatening. The risk of hip fracture rises with age. Older people are at a ...

  12. Fibular grafting with cannulated hip screw fixation in late femoral neck fracture in young adults

    Directory of Open Access Journals (Sweden)

    Goyal R

    2006-01-01

    Full Text Available Background: We reviewed the operative results of fibular bone graft with cannulated hip screw fixation in femoral neck fracture in young adults. Method: Sixteen young adults with femoral neck fracture were treated by fibular bone graft with cannulated hip screw fixation. All the fractures were more than 3 weeks old. Results: Results were assessed in 15 patients while one patient died due to complications not related to surgery. Union occurred in all 15 patients. One patient had intra-operative complication in the form of screw cut out with graft in the joint space. The average fallow up was 24.4 months. Out of 15 patients assessed clinico-radiologically 11 showed good results, 3 had fair while 1 had poor result. Conclusion: We conclude that this is a simple and cost effective procedure for late femoral fleck fracture in young adults with good results.

  13. [Meta-analysis of internal fixation versus hip replacement in the treatment of trochanteric fractures].

    Science.gov (United States)

    Dong, Jian-Bin; Wang, Zhi-Yong; Lu, Hao; Tian, Yuan; Wang, Xin-Rui; Zhang, Zhi-Qiang

    2015-03-01

    To compare the efficacy of internal fixation (including PFNA and PFN) versus hip replacement (including FHR or THA) in the treatment of trochanteric fractures in adults. Reports of studies using randomized controlled trials (RCT) to compare internal fixationg with hip replacement in the management of intertrochanteric fractures were retrieved (up to January 1, 2013) from the Cochrane Library, PUBMED Data, CNKI (China National Knowledge infrastructure), Elsevier, the Chinese Biomedical Database, Wanfang Data, and manually. Methodological quality of the trials was critically assessed, and relevant data were extracted. Statistical software RevMan 5.0 was used for data-analysis. Seven articles were included in the meta-analysis. The results showed that,compared internal fixation with hip replacement,there were statistical significance in the duration of surgery time [WMD = -2.66, 95% CI (-5.25,-0.06), P = 0.05], intra-operative blood loss [WMD = -24.20, 95% CI (-30.38, -18.02), P 0.05]. CON- CLUSION: Hip replacement (containing FHR or THA) for the treatment of intertrochanteric fractures is superior to internal fixa- tion in regards to the duration of surgery time, the mean duration of hosipital stays, mean post-operative down time, intra-opera- tive blood loss, the rate of post-operative good Harris scores. But there is not enough evidence to show any difference between hip replacement (containing THA or FHR) and internal fixation in regards to the rate of deep venous thrombosis. However, internal fixation for the treatment of intertrochanteric fractures is superior to hip replacement (containing FHR or THA) in regards to total complications rate.

  14. Radiation exposure from fluoroscopy during fixation of hip fracture and fracture of ankle: Effect of surgical experience

    Directory of Open Access Journals (Sweden)

    Botchu Rajesh

    2008-01-01

    Full Text Available Background: Over the years, there has been a tremendous increase in the use of fluoroscopy in orthopaedics. The risk of contracting cancer is significantly higher for an orthopedic surgeon. Hip and spine surgeries account for 99% of the total radiation dose. The amount of radiation to patients and operating surgeon depends on the position of the patient and the type of protection used during the surgery. A retrospective study to assess the influence of the radiation exposure of the operating surgeon during fluoroscopically assisted fixation of fractures of neck of femur (dynamic hip screw and ankle (Weber B was performed at a district general hospital in the United Kingdom. Materials and Methods: Sixty patients with undisplaced intertrochanteric fracture were included in the hip group, and 60 patients with isolated fracture of lateral malleolus without communition were included in the ankle group. The hip and ankle groups were further divided into subgroups of 20 patients each depending on the operative experience of the operating surgeon. All patients had fluoroscopically assisted fixation of fracture by the same approach and technique. The radiation dose and screening time of each group were recorded and analyzed. Results: The radiation dose and screening time during fluoroscopically assisted fixation of fracture neck of femur were significantly high with surgeons and trainees with less than 3 years of surgical experience in comparison with surgeons with more than 10 years of experience. The radiation dose and screening time during fluoroscopically assisted fixation of Weber B fracture of ankle were relatively independent of operating surgeon′s surgical experience. Conclusion: The experience of operating surgeon is one of the important factors affecting screening time and radiation dose during fluoroscopically assisted fixation of fracture neck of femur. The use of snapshot pulsed fluoroscopy and involvement of senior surgeons could

  15. Hip fracture fixation in a patient with below-knee amputation presents a surgical dilemma: a case report

    Directory of Open Access Journals (Sweden)

    Rethnam Ulfin

    2008-09-01

    Full Text Available Abstract Introduction Hip fracture fixation surgery in patients with below-knee amputations poses a challenging problem to the surgeon in terms of obtaining traction for reduction of the fracture. The absence of the foot and part of the leg in these patients makes positioning on the fracture table difficult. We highlight this difficult problem and suggest techniques to overcome it. Case presentation A 73-year-old man with bilateral below-knee amputations presented with a history of fall. Radiographs revealed an inter-trochanteric fracture of the femur. A dynamic hip screw fixation was planned for the fracture but the dilemma was on how to position the patient on the fracture table for the surgery. Special attention was needed in positioning the patient and in surgical fixation of the fracture. Conclusion Hip fracture fixation in patients with below-knee amputations poses a special problem in positioning for fracture reduction and fixation. In this case report, we share our experience and suggest techniques to use when encountering this difficult problem.

  16. Hip fracture fixation in a patient with below-knee amputation presents a surgical dilemma: a case report

    OpenAIRE

    Rethnam Ulfin; Yesupalan Rajam; Shoaib Amer; Ratnam Thanga K

    2008-01-01

    Abstract Introduction Hip fracture fixation surgery in patients with below-knee amputations poses a challenging problem to the surgeon in terms of obtaining traction for reduction of the fracture. The absence of the foot and part of the leg in these patients makes positioning on the fracture table difficult. We highlight this difficult problem and suggest techniques to overcome it. Case presentation A 73-year-old man with bilateral below-knee amputations presented with a history of fall. Radi...

  17. Functional Recovery Following Pertrochanteric Hip Fractures Fixated with the Dynamic Hip Screw vs. the Percutaneous Compression Plate

    Directory of Open Access Journals (Sweden)

    Yocheved Laufer

    2005-01-01

    Full Text Available The Dynamic Hip Screw (DHS is currently the most frequently used implant for the treatment of pertrochanteric hip fractures. The Percutaneous Compression Plate (PCCP is a recently developed, alternative device that involves minimal invasive surgery. The objective of the present study was to compare functional recovery following these two surgical procedures. A total of 76 consecutive elderly subjects (mean age and standard deviation, 80.6 ± 5.5 following pertrochanteric hip fracture fixation were evaluated prospectively. Functional recovery was assessed 3 and 12 weeks and 2 years following surgery. Differences between groups 3 weeks postsurgery were found only in pain level during ambulation and in the weight-bearing capability of the operated extremity, which were both in favor of the PCCP. By 3 months, both groups had improved in all measures, but did not reach their preinjury level of independence. However, the PCCP group ambulated with fewer assistive devices and demonstrated better recovery of basic activities of daily living (BADL. While the majority of the subjects from both groups ambulated independently 2 years postsurgery, the PCCP group exhibited less pain during ambulation, was more independent in ADL, and required fewer assistive devices for ambulation. To summarize, the PCCP presents enhanced short- and long-term recovery of functional abilities in comparison to DHS. However, given the limited number of patients, further studies are necessary to substantiate these results.

  18. [Comparison of effects between two operating methods of treating intertrochanteric hip fracture with Gamma nail fixation].

    Science.gov (United States)

    Chen, Qin; Zhou, Zheng; Guan, Long

    2007-10-01

    To evaluate the surgical efficiency of treating the intertrochanteric hip fracture with the Gamma nail fixation and to compare two operating methods of the Gamma nail fixation. From August 2000 to August 2006, 69 patients (32 males, 37 females; age, 43-98 years;average, 72.3 years) with the intertrochanteric hip fracture but with no associated injury were treated with the Gamma nail fixation. The patients' average illness course was 5. 6 days (range, 3-14 days). Among the 69 patients, 36 were treated with the traditional method of the Gamma nail fixation (Group A) and 33 were treated with an improved method of the Gamma nail fixation (Group B). According to the Association for the Study of Internal Fixation (AO-ASIF) classification, in Group A, 5 patients had a disease of Type A1, 23 of Type A2, and 8 of Type A3; in Group B, 8 patients had a disease of Type A1, 21 of Type A2, and 4 of Type A3. The data from the two groups were analyzed, and the statistical analysis was made on the following aspects: incision length, operating time, intraoperative bleeding, X-ray exposure frequency, drainage amount, blood transfusion volume, postoperative infection of the lungs, superficial infection of the incision, duration of antibiotic use, standing with the walking stick after operation, complication due to internal fixation, healing time for the fracture, and the hip function recovery half a year after operation assessed with the Harris scoring system. All the 69 patients were followed up for 8-80 months (average, 42 months). We studied the indexes such as incision length, operating time, intraoperative bleeding, X-ray exposure frequency, drainage amount, and blood transfusion volum; above indexes in Group A were 9.5 +/- 4.7 cm, 85 +/- 35 min, 186.0 +/- 87.3 ml, 9.0 +/- 5.1 times, 102.7 +/- 49.8 ml, 325.0 +/- 169.5 ml; and those were 5.3 +/- 1.2 cm, 46 +/- 10 min, 65.0 +/- 26.0 ml, 3.0 +/- 2.1 times, 52.5 +/- 16.2 ml, 203.0 +/- 61.2 ml in Group B. The above indexes showed that

  19. Scattered radiation during fixation of hip fractures. Is distance alone enough protection?

    Science.gov (United States)

    Alonso, J A; Shaw, D L; Maxwell, A; McGill, G P; Hart, G C

    2001-08-01

    We measured the scattered radiation received by theatre staff, using high-sensitivity electronic personal dosimeters, during fixation of extracapsular fractures of the neck of the femur by dynamic hip screw. The dose received was correlated with that received by the patient, and the distance from the source of radiation. A scintillation detector and a water-filled model were used to define a map of the dose rate of scattered radiation in a standard operating theatre during surgery. Beyond two metres from the source of radiation, the scattered dose received was consistently low, while within the operating distance that received by staff was significant for both lateral and posteroanterior (PA) projections. The routine use of lead aprons outside the 2 m zone may be unnecessary. Within that zone it is recommended that lead aprons be worn and that thyroid shields are available for the surgeon and nursing assistants.

  20. Lateral migration with telescoping of a trochanteric fixation nail in the treatment of an intertrochanteric hip fracture

    Institute of Scientific and Technical Information of China (English)

    Liu Wanjun; Wang Junqiang; Michael J.Weaver; Mark S.Vrahas; Zhou Dongsheng

    2014-01-01

    Background The trochanteric fixation nail (TFN) can be used to treat stable and unstable fractures of intertrochanteric hip fractures.We study the common lateral migration that occurs with telescoping of intertrochanteric hip fractures treated with TFN and identify the predictors and relationships to clinical outcomes.Methods Patient demographic information,fracture type (Arbeitsgemeinschaft für Osteosynthesefragen (AO)/Orthopaedic Trauma Association (OTA) classification),radiographic data,and clinical data were collected.Lateral migration with telescoping was measured.Statistical analyses were performed to determine which variables predicted lateral migration with telescoping.Patient outcome scores were recorded using the Modified Harris Hip Score (MHHS),Hip Outcome Score-Activity of Daily Living (HOS-ADL),and Visual Analog Scale for pain.Results Two hundred and twenty-three patients (67 males,156 females) fitted the radiographic and follow-up (average 24.6 months) criteria.The average age was 77.2 years.The average lateral migration with telescoping was 4.8 mm.Twenty-one patients (9.4%) had excessive lateral migration with telescoping (≥10 mm).The quality of calcar reduction (P=0.01) and unstable fracture patterns (P=0.006) were significant predictive factors of lateral migration with telescoping.The mean outcome scores (MHHS and HOS-ADL) were 80.1 points and 78.7 points,respectively.All subjects had no significant relationship to lateral migration with telescoping (P >0.05).Of all the patients who developed lateral migration with telescoping,only one required removal of the blade for hip pain and all patients went on to uneventful union at an average time of 4.5 months.Conclusions Lateral migration with telescoping is a common mechanical complication of intertrochanteric hip fracture treated with the TFN procedure.It was predicted by the quality of calcar reduction and fracture type.However,this did not affect stable fixation and fracture healing

  1. Quality of life following total hip arthroplasty in patients with acetabular fractures, previously managed by open reduction and internal fixation

    Institute of Scientific and Technical Information of China (English)

    Prasoon Kumar; Ramesh Kumar Sen; Vishal Kumar; Ankit Dadra

    2016-01-01

    Purpose:Total hip replacement (THR) is one of the most successful and cost-effective surgical procedures and remains the treatment of choice for long-term pain relief and restoration of function for patients with diseased or damaged hips.Acetabular fractures managed either conservatively or operatively by fixation tend to present later with secondary joint changes that require THR.In this study we evaluated the functional outcome and quality of life achieved by such patients.Methods:Our study was carried out as a retrospective trial by recruiting patients who underwent THR from June 2006 to May 2012.A total of 32 patients were included with a mean age of 46.08 years ranging from (25-65) years.We evaluated the quality of life in the patients using scoring techniques of Short Musculoskeletal Functional Assessment (SMFA) and the 12-Item Short Form Health Survey (SF-12).Functional outcome was assessed using Harris Hip Score (HHS).Results:The mean HHS of the patients was 84.3 with a range from 56 to 100.The SMFA averaged 13.3.The SF-12 score averaged 49.1.The correlation of the HHS with SF-12 was positive (p =0.001) while with SMFA there was a negative correlation (p =0.001).Conclusion:From this study it is inferred that the functional outcome of THR and quality of life in patients who had acetabular fractures and were initially managed by open reduction and internal fixation is good.

  2. Iatrogenic Injury of Profunda Femoris Artery Branches after Intertrochanteric Hip Screw Fixation for Intertrochanteric Femoral Fracture: A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Nikolaos Patelis

    2014-01-01

    Full Text Available A case of arterial rupture of the profunda femoris arterial branches, following dynamic hip screw (DHS fixation for an intertrochanteric femoral fracture, is presented. Bleeding is controlled by coil embolization, but, later on, the patient underwent orthopedic material removal due to an infection of a large femoral hematoma.

  3. Hip fracture - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000168.htm Hip fracture - discharge To use the sharing features on this page, please enable JavaScript. Hip fracture surgery is done to repair a break in ...

  4. Hip fracture surgery

    Science.gov (United States)

    ... neck fracture repair; Trochanteric fracture repair; Hip pinning surgery; Osteoarthritis - hip ... You may receive general anesthesia for this surgery. This means you ... spinal anesthesia . With this kind of anesthesia, medicine is ...

  5. A Biomechanical Study Comparing Helical Blade with Screw Design for Sliding Hip Fixations of Unstable Intertrochanteric Fractures

    Directory of Open Access Journals (Sweden)

    Qiang Luo

    2013-01-01

    Full Text Available Dynamic hip screw (DHS is a well-established conventional implant for treating intertrochanteric fracture. However, revision surgery sometimes still occurs due to the cutting out of implants. A helical blade instead of threaded screw (DHS blade was designed to improve the fixation power of the osteoporotic intertrochanteric fracture. In this study, the biomechanical properties of DHS blade compared to the conventional DHS were evaluated using an unstable AO/OTA 31-A2 intertrochanteric fracture model. Fifty synthetic proximal femoral bone models with such configuration were fixed with DHS and DHS blade in five different positions: centre-centre (CC, superior-centre (SC, inferior-center (IC, centre-anterior (CA, and centre-posterior (CP. All models had undergone mechanical compression test, and the vertical and rotational displacements were recorded. The results showed that DHS blade had less vertical or rotational displacement than the conventional DHS in CC, CA, and IC positions. The greatest vertical and rotational displacements were found at CP position in both groups. Overall speaking, DHS blade was superior in resisting vertical or rotational displacement in comparison to conventional DHS, and the centre-posterior position had the poorest performance in both groups.

  6. Biomechanical evaluation of adjunctive cerclage wire fixation for the prevention of periprosthetic femur fractures using cementless press-fit total hip replacement.

    Science.gov (United States)

    Christopher, Scott A; Kim, Stanley E; Roe, Simon; Pozzi, Antonio

    2016-08-01

    Periprosthetic femoral fractures are a common complication associated with cementless press-fit total hip arthroplasty. The use of prophylactic cerclage wire fixation has been advocated to reduce this complication. The objective of this study was to evaluate whether a double loop cerclage wire, used as adjunctive fixation, increased the peak torsional load to failure in femora implanted with press-fit cementless stems. Peak torsional load to failure was compared between femora without adjunctive fixation and femora receiving a 1 mm double loop cerclage wire placed proximally to the lesser trochanter. Femora treated with adjunctive cerclage wire fixation failed at 20% greater peak torque (P = 0.0001). In conclusion, a double loop cerclage wire may aid in the prevention of periprosthetic fractures associated with press-fit cementless femoral stems.

  7. Hip Fractures among Older Adults

    Science.gov (United States)

    ... online training for health care providers. Learn More Hip Fractures Among Older Adults Recommend on Facebook Tweet Share ... get older. What You Can Do to Prevent Hip Fractures You can prevent hip fractures by taking steps ...

  8. Infection in periprosthetic hip fractures.

    Science.gov (United States)

    Cabral, Rui

    2012-01-01

    Fracture around the acetabulum and femur in total hip arthroplasty is a possible complication, sometimes with difficult surgical solution, namely when a sepsis is present. Periprosthetic hip fractures were classified according to a modified Vancouver classification. We treated 112 patients (67 men and 45 women) with periprosthetic hip fractures: 105 femoral fractures (94%) and seven acetabular fractures (6%). Mean follow-up was 10.6 years. For Type A (seven cases - 7%), B1 (10 cases - 10%) or C (13 cases - 12%) fractures around well fixed femoral stems we only fixed the fractures. For Type B2 (17 cases - 16%), B3 (46 cases - 44%) and D (12 cases - 11%, with associated fractures, not contemplated in the Vancouver classification) we used an uncemented long femoral stem, fixation with metallic cables and cancellous bone allografts to fill the femoral bone loss. We observed a deep infection in three patients (2.7%), three early hip dislocations treated by closed reductions, two cases with asymptomatic trochanteric non-union and one femoral refracture. In the three infection cases we performed two-stage revision with cementless hip prosthesis, using an antibiotic-loaded cement hip spacer (three to eight months), a six weeks period of parenteral antibiotics and we performed articular aspiration before revision surgery. Until now, we did not observe any re-infection. It is very important to make an early diagnosis, isolate micro-organisms and ensure their antibiotic susceptibility. The surgery solution depends on the well fixed implants and periprosthetic osteolysis and articular instability.

  9. Fracture After Total Hip Replacement

    Science.gov (United States)

    ... osteolysis. Symptoms The most common symptoms of periprosthetic hip fracture include: • Pain around the hip or thigh • Swelling ... o en very painful, someone with a periprosthetic hip fracture will most likely go directly to the emergency ...

  10. Prevention of hip fractures.

    Science.gov (United States)

    Meunier, P J

    1993-11-30

    For a 50-year old Caucasian woman today, the risk of a hip fracture over her remaining life-time is about 17%. Tomorrow the situation will clearly be worse because the continuous increase in life expectancy will cause a three-fold increase in worldwide fracture incidence over the next 60 years. Through diagnostic bone mass measurements at the hip and assessment of biochemical parameters, a great deal has been learned in recent years about reduction of hip fracture risk. Preventive strategies are based on prevention of falls, use of hip protectors, and prevention of bone fragility. The latter includes the optimization of peak bone mass during childhood, postmenopausal estrogen replacement therapy, and also late prevention consisting in reversing senile secondary hyperparathyroidism, which plays an important role in the decrease of skeletal strength. This secondary hyperparathyroidism, which results from both vitamin D insufficiency and low calcium intake, is preventable with vitamin D3 and calcium supplements. They have recently been shown capable of providing effective prevention of hip fractures in elderly women living in nursing homes, with a reduction of about 25% in the number of hip fractures noted in a 3-year controlled study in 3,270 women (intention-to-treat analysis). In conclusion, it is never too early to reduce the risk of osteoporosis and never too late to prevent hip fractures.

  11. Total hip arthroplasty after previous fracture surgery.

    Science.gov (United States)

    Krause, Peter C; Braud, Jared L; Whatley, John M

    2015-04-01

    Total hip arthroplasty can be a very effective salvage treatment for both failed fracture surgery and hip arthritis that may occur after prior fracture surgery. The rate of complications is significantly increased including especially infection, dislocation, and loosening. Complications are more likely to occur after failed open reduction and internal fixation than after posttraumatic arthritis. Adequately ruling out infection before hip arthroplasty can be difficult. The best predictor of infection is a prior infection. Long-term outcomes can be comparable to outcomes in other conditions if complications are avoided.

  12. Flexible fixation and fracture healing

    DEFF Research Database (Denmark)

    Schmal, Hagen; Strohm, Peter C; Jaeger, Martin

    2011-01-01

    to the bone surface than external fixator bars. External fixators have the advantage of being less expensive, highly flexible, and technically less demanding. They remain an integral part of orthopaedic surgery for emergent stabilization, for pediatric fractures, for definitive osteosynthesis in certain...

  13. Reliability of predictors for screw cutout in intertrochanteric hip fractures

    NARCIS (Netherlands)

    K.M.J. de Bruijn (Kirstin); D. den Hartog (Dennis); W.E. Tuinebreijer (Wim); G.R. Roukema (Gert)

    2012-01-01

    textabstractBackground: Following internal fixation of intertrochanteric hip fractures, tip apex distance, fracture classification, position of the screw in the femoral head, and fracture reduction are known predictors for screw cutout, but the reliability of these measurements is unknown. We invest

  14. Pediatric Hip Fractures in California: Results from a Community-Based Hip Fracture Registry.

    Science.gov (United States)

    Prentice, Heather A; Paxton, Elizabeth W; Hunt, Jessica J; Grimsrud, Christopher D; Weiss, Jennifer M

    2017-01-01

    Hip fracture registries offer an opportunity to identify and to monitor patients with rare conditions and outcomes, including hip fractures in pediatric patients. To report patient demographics and surgical outcomes of pediatric patients treated surgically for hip fractures in a large integrated health care system. Pediatric patients (fracture) with hip fractures were identified between 2009 and 2012 using our health care system's hip fracture registry. Patient characteristics, type of fracture, surgical treatment, and short-term complications. Among 39 patients identified, 31 (79.5%) were male, and the median age was 15 years old (interquartile range: 11-17 years). Most patients were Hispanic (n = 17, 43.6%) or white (n = 14, 35.9%). There were 8 patients (20.5%) with 15 comorbidities. Delbet Type IV (intertrochanteric) fractures were the most common fracture type (n = 22, 56.4%), and fixation method was equally distributed between intramedullary, screw and sideplate, and screws (n = 12, 30.8% for each). Most surgeries were performed by medium-volume surgeons (n = 22, 56.4%) at medium- and high-volume hospitals (n = 37, 94.9%). Three 90-day readmissions (7.7%), 1 infection (2.6%), 1 malunion (2.6%), and 1 revision (2.6%) were observed in this cohort during the study period. In our series using registry data, hip fractures younger than age 21 years were more common in boys and Hispanic patients. Intertrochanteric fractures (Delbet Type IV) were the most frequently observed type in our community-based hip fracture registry. Short-term complications were infrequent.

  15. Subtrochanteric femur fracture treated by intramedullary fixation

    Institute of Scientific and Technical Information of China (English)

    Zu-Bin Zhou; Song Chen; You-Shui Gao; Yu-Qiang Sun; Chang-Qing Zhang; Yao Jiang

    2015-01-01

    Purpose: To discuss surgical technique, operative efficacy and clinical outcome of intramedullary fixation in the treatment of subtrochanteric femur fractures.Methods: From February 2011 to February 2013, 76 cases of subtrochanteric femur fractures were treated by intramedullary fixation in our hospital, including 53 males and 23 females, with the age range of 37 -72 years (mean 53.5 years).According to Seinsheimer classification, there were 2 cases of type Ⅰ, 7 type Ⅱ,15 type Ⅲ, 23 type Ⅳ and 29 type Ⅴ.Firstly, all patients underwent closed reduction with the guidance of C-arm fluoroscopy in a traction table.Two cases of type Ⅰ and 3 cases of type Ⅲ fractures had ideal closed reduction followed by internal fixation.The others needed additional limited open reduction.Radiographic examination was used to evaluate callus formation and fracture healing in postoperative 1, 3, 6 and 12 months follow-up.Functional recovery was evaluated by Harris Hip Scoring (HHS) system.Results: Patients were followed up for 6-12 months.All fractures were healed except one patient with delayed union.The average bone union time was 4.5 months.According to HHS system, 65 cases were considered as excellent in functional recovery, 8 good, 2 fair and 1 poor.The proportion of the patients with excellent and good recovery was 96.05%.Conclusion: Intramedullary fixation is feasible for the treatment of subtrochanteric femur fracture.The accuracy of intraoperative reduction and surgical skill are important for the clinical outcome and the patients' prognosis.

  16. Reverse LISS plating for intertrochanteric Hip Fractures in elderly patients

    Directory of Open Access Journals (Sweden)

    Chen SB

    2010-07-01

    Full Text Available Abstract Background Fractures of the intertrochanteric hip are common and the treatment of unstable fractures generally requires an operative approach. In elderly patients, osteoporosis makes internal fixation problematic and frequently contributes to failed fixation and poor clinical results. We have attempted to apply the Less Invasive Stabilization System (LISS in reverse position for the repair of intertrochanteric hip fractures in elderly patients with osteoporotic bones. A retrospective review is presented of the cases of 28 elderly patients with stable and unstable fractures of the intertrochanteric hip treated using the reverse LISS. Methods We treated 28 elderly patients with a mean age of 82.3 years. According to the Evens classification, there were 2 Type I fractures, 2 Type II fractures, 3 Type III fractures, 13 Type IV fractures, 6 Type V fractures and 2 Type R fractures. All fractures were treated using the reverse LISS. Radiographic and clinical evidence of functional outcome and complications were evaluated. Results Mean perioperative blood loss was 92.4 milliliters (range 35 to 245 milliliters, and the mean postoperative hospital stay was 8.7 days (range 3 to 14 days. Complications included one minor wound hematoma. Radiographically, no collapses, screw cutouts, or head penetrations were seen. All surviving patients (28 of 28; 100 percent had uneventful fracture healing with union achieved by six months in all patients. Conclusions Use of the Reverse LISS plating for intertrochanteric hip fractures resulted in event-free fracture healing.

  17. Social inequality and hip fracture

    DEFF Research Database (Denmark)

    Harvey, N. C.; Hansen, L.; Judge, A.

    2015-01-01

    Social inequality appears to be increasing in many countries. We explored whether risk of hip fracture was associated with markers of inequality and whether these relationships changed with time, using data from Danish Health Registries. Methods: All patients 60 years or older with a primary hip...

  18. Excess mortality following hip fracture

    DEFF Research Database (Denmark)

    Abrahamsen, B; van Staa, T; Ariely, R;

    2009-01-01

    Summary This systematic literature review has shown that patients experiencing hip fracture after low-impact trauma are at considerable excess risk for death compared with nonhip fracture/community control populations. The increased mortality risk may persist for several years thereafter, highlig...

  19. Pathogenesis of osteoporotic hip fractures.

    Science.gov (United States)

    McClung, Michael R

    2003-01-01

    Osteoporosis is characterized late in the course of the disease by an increased risk of fracture, particularly in the elderly. It occurs in both sexes, affecting approximately 8 million women and 2 million men aged > or = 50 years (1). While low bone density is a predictor of fractures, it is not the only determinant of fracture risk. Other factors include advanced age, altered bone quality, a personal or family history of falls, frailty, poor eyesight, debilitating diseases, and high bone turnover. A diet with sufficient calcium and vitamin D is important to minimize bone loss and, along with regular exercise, to maintain muscle strength. Bisphosphonates have been shown to reduce the risk of hip fracture. For elderly patients, the use of hip protectors may be used as a treatment of last resort. Regardless of the age of the patient, individual patient risk factors must be considered to target appropriate treatment and prevent fracture.

  20. Dynamic Hip Screw Fixation Combined of Oral Medicine Treating Intertrochanteric Fracture%动力髋螺钉固定术配合口服中药治疗高龄股骨粗隆间骨折

    Institute of Scientific and Technical Information of China (English)

    徐爱民

    2012-01-01

    目的:探讨采用动力髋螺钉(DHS)固定术配合口服中药治疗高龄股骨粗隆间骨折的方法和疗效.方法:对2004年1月—2009年1月收治的股骨粗隆间骨折患者进行手术治疗.其中男25例,女21例,年龄65~83岁,平均年龄73岁,采用动力髋螺钉(DHS)固定术.结果:1例病人术后3天出现患肢深静脉血栓,经活血、溶栓治疗后恢复.2例因其他疾病死亡,43例骨折均全部愈合,已恢复原来生活能力,无内固定物松动及髋内翻畸形等并发症.结论:动力髋螺钉(DHS)固定术配合口服中药治疗高龄股骨粗隆间骨折具有操作简单、时间短、固定可靠、损伤小、出血少、骨折愈合率高、并发症少等优点,是值得推广应用的手术方法[1].%Objective:To investigate the method and effect of the dynamic hip screw ( DHS )fixation of intertrochanteric fracture. Methods; During January 2004-January 2009, patients admitted because of intertrochanteric fractures were treated surgically, including 25 males and 21 females, aged 65 to 83 years old, mean age was 73, using dynamic hip screw ( DHS ) fixation. Results: 3 days after surgery, 1 case limb deep vein thrombosis occurs, the blood circulation restored after thrombolytic therapy. 2 patients died due to other diseases,43 cases of fracture were all healed and returned to the original capacity, no loosening of internal fixation, or complications such as varus deformity. Conclusion: The dynamic hip screw ( DHS ) fixation combined with oral medicine treatment of intertrochanteric fracture is simple, treatment course is short, fixed and reliable, with less damage, less bleeding, high fracture healing rate, fewer complications, and is worthy of promoting application for the surgical method[1].

  1. Risk factors for deep vein thrombosis in lower extremity after hip or knee arthroplasty and hip fracture internal fixation%髋、膝关节矫形术和髋部骨折内固定术后病人下肢深静脉血栓形成的危险因素

    Institute of Scientific and Technical Information of China (English)

    宋琳琳; 吴新民; 袁训芝

    2010-01-01

    Objective To determine the factors contributing to the development of deep vein thrombosis (DVT) in the lower extremity in patients after hip or knee arthroplasty and hip fracture internal fixation.Methods One hundred and forty-seven consecutive patients receiving hip or knee arthroplasty and hip fracture internal fixation from 2004 to 2005 were included in this study. Their age ranged from 33 to 92 years. Duplex color ultrasonic inspection was performed on veins of the bilateral lower extremities before operation and 2 weeks after operation for detection of DVT. The patients were divided into a DVT group and a DVT-free group based on the development of DVT after operation. Detailed perioperative clinical information about the patients, surgery and anesthesia was collected.Results Lower extremity DVT was found in 42.2% of the patients after operation, while the incidence of proximal DVT was 2.7%. Compared with the DVT-free group, the usage rate and dosage of ephedrine increased significantly, the duration of anesthesia was significantly longer, and the white blood cell count (WBC) on the 1st postoperative day and the highest WBC count were significantly higher in the DVT group(P<0.05). Logistic regression analysis indicated that the above factors were closely related to DVT.Conclusion Duration of anesthesia > 3 h, ephedrine administration and a marked increase in WBC count after operation are the risk factors for DVT in the lower extremities in patients after hip or knee arthroplasty and hip fracture internal fixation.

  2. Periprosthetic femoral fracture within two years after total hip replacement:

    DEFF Research Database (Denmark)

    Thien, T. M.; Chatziagorou, G.; Garellick, G.;

    2014-01-01

    BACKGROUND: We used the Nordic Arthroplasty Register Association database to evaluate whether age, sex, preoperative diagnosis, fixation, and implant design influence the risk of revision arthroplasty due to periprosthetic fracture within two years from operation of a primary total hip replacemen...

  3. Correlation of hip fracture with other fracture types: Toward a rational composite hip fracture endpoint.

    Science.gov (United States)

    Colón-Emeric, Cathleen; Pieper, Carl F; Grubber, Janet; Van Scoyoc, Lynn; Schnell, Merritt L; Van Houtven, Courtney Harold; Pearson, Megan; Lafleur, Joanne; Lyles, Kenneth W; Adler, Robert A

    2015-12-01

    With ethical requirements to the enrollment of lower risk subjects, osteoporosis trials are underpowered to detect reduction in hip fractures. Different skeletal sites have different levels of fracture risk and response to treatment. We sought to identify fracture sites which cluster with hip fracture at higher than expected frequency; if these sites respond to treatment similarly, then a composite fracture endpoint could provide a better estimate of hip fracture reduction. Cohort study using Veterans Affairs and Medicare administrative data. Male Veterans (n=5,036,536) aged 50-99 years receiving VA primary care between 1999 and 2009 were included. Fractures were ascertained using ICD9 and CPT codes and classified by skeletal site. Pearson correlation coefficients, logistic regression and kappa statistics were used to describe the correlation between each fracture type and hip fracture within individuals, without regard to the timing of the events. 595,579 (11.8%) men suffered 1 or more fractures and 179,597 (3.6%) suffered 2 or more fractures during the time under study. Of those with one or more fractures, the rib was the most common site (29%), followed by spine (22%), hip (21%) and femur (20%). The fracture types most highly correlated with hip fracture were pelvic/acetabular (Pearson correlation coefficient 0.25, pfractures cluster with hip fractures within individuals at greater than expected frequency. If we observe similar treatment risk reductions within that cluster, subsequent trials could consider the use of a composite endpoint to better estimate hip fracture risk. Published by Elsevier Inc.

  4. Routine functional assessment for hip fracture patients

    DEFF Research Database (Denmark)

    Pedersen, Tonny J; Lauritsen, Jens M

    2016-01-01

    Background and purpose - Pre-fracture functional level has been shown to be a consistent predictor of rehabilitation outcomes in older hip fracture patients. We validated 4 overall pre-fracture functional level assessment instruments in patients aged 65 or more, used the prediction of outcome at 4...... months post-fracture, and assessed cutoff values for decision making in treatment and rehabilitation. Patients and methods - 165 consecutive patients with acute primary hip fracture were prospectively included in the study. Pre-fracture Barthel-20, Barthel-100, cumulated ambulation score, and new...... investigation of usage for guidance of clinical and rehabilitation decisions concerning hip fracture patients is warranted....

  5. Navigated percutaneous screw fixation of a periprosthetic acetabular fracture.

    Science.gov (United States)

    Gras, Florian; Marintschev, Ivan; Klos, Kajetan; Fujak, Albert; Mückley, Thomas; Hofmann, Gunther O

    2010-10-01

    Periprosthetic fractures are severe complications of total hip arthroplasty with increasing incidence. Most fractures are localized around the femoral component of prosthesis, whereas periacetabular fractures are rare and their management is difficult. In most cases, an operative procedure with revision and exchange of the acetabular cup is necessary. The approaches are demanding and an increased risk of complications is reported. We present the case of a female patient with a cementless total hip arthroplasty due to severe arthritis, suffering of an infratectal transverse periprosthetic fracture. After an initial conservative treatment attempt, we performed a minimally invasive screw fixation using navigated 2-dimensional fluoroscopic guidance. In this report, the literature for treatment recommendations is reviewed and the chosen navigation technique discussed. Copyright © 2010. Published by Elsevier Inc.

  6. Economic viability of geriatric hip fracture centers.

    Science.gov (United States)

    Clement, R Carter; Ahn, Jaimo; Mehta, Samir; Bernstein, Joseph

    2013-12-01

    Management of geriatric hip fractures in a protocol-driven center can improve outcomes and reduce costs. Nonetheless, this approach has not spread as broadly as the effectiveness data would imply. One possible explanation is that operating such a center is not perceived as financially worthwhile. To assess the economic viability of dedicated hip fracture centers, the authors built a financial model to estimate profit as a function of costs, reimbursement, and patient volume in 3 settings: an average US hip fracture program, a highly efficient center, and an academic hospital without a specific hip fracture program. Results were tested with sensitivity analysis. A local market analysis was conducted to assess the feasibility of supporting profitable hip fracture centers. The results demonstrate that hip fracture treatment only becomes profitable when the annual caseload exceeds approximately 72, assuming costs characteristic of a typical US hip fracture program. The threshold of profitability is 49 cases per year for high-efficiency hip fracture centers and 151 for the urban academic hospital under review. The largest determinant of profit is reimbursement, followed by costs and volume. In the authors’ home market, 168 hospitals offer hip fracture care, yet 85% fall below the 72-case threshold. Hip fracture centers can be highly profitable through low costs and, especially, high revenues. However, most hospitals likely lose money by offering hip fracture care due to inadequate volume. Thus, both large and small facilities would benefit financially from the consolidation of hip fracture care at dedicated hip fracture centers. Typical US cities have adequate volume to support several such centers.

  7. Facts and fiction in hip fracture treatment

    NARCIS (Netherlands)

    Embden, Daphne van

    2016-01-01

    As the number of hip fracture patients has increased dramatically over the years, the need for high quality, multidisciplinary and patient centred fracture treatment continues to grow. The first aim of this thesis is to provide better understanding of fracture patterns and classification in hip

  8. Hip fracture in hospitalized medical patients

    Directory of Open Access Journals (Sweden)

    Zapatero Antonio

    2013-01-01

    Full Text Available Abstract Background The aim of the present study is to analyze the incidence of hip fracture as a complication of admissions to internal medicine units in Spain. Methods We analyzed the clinical data of 2,134,363 adults who had been admitted to internal medicine wards. The main outcome was a diagnosis of hip fracture during hospitalization. Outcome measures included rates of in-hospital fractures, length of stay and cost. Results A total of 1127 (0.057% admittances were coded with an in-hospital hip fracture. In hospital mortality rate was 27.9% vs 9.4%; p  Conclusions In-hospital hip fracture notably increased mortality during hospitalization, doubling the mean length of stay and mean cost of admission. These are reasons enough to stress the importance of designing and applying multidisciplinary plans focused on reducing the incidence of hip fractures in hospitalized patients.

  9. Hip fracture: diagnosis, treatment, and secondary prevention.

    Science.gov (United States)

    LeBlanc, Kim Edward; Muncie, Herbert L; LeBlanc, Leanne L

    2014-06-15

    Hip fractures cause significant morbidity and are associated with increased mortality. Women experience 80% of hip fractures, and the average age of persons who have a hip fracture is 80 years. Most hip fractures are associated with a fall, although other risk factors include decreased bone mineral density, reduced level of activity, and chronic medication use. Patients with hip fractures have pain in the groin and are unable to bear weight on the affected extremity. During the physical examination, displaced fractures present with external rotation and abduction, and the leg will appear shortened. Plain radiography with cross-table lateral view of the hip and anteroposterior view of the pelvis usually confirms the diagnosis. If an occult hip fracture is suspected and plain radiography is normal, magnetic resonance imaging should be ordered. Most fractures are treated surgically unless the patient has significant comorbidities or reduced life expectancy. The consulting orthopedic surgeon will choose the surgical procedure. Patients should receive prophylactic antibiotics, particularly against Staphylococcus aureus, before surgery. In addition, patients should receive thromboembolic prophylaxis, preferably with low-molecular-weight heparin. Rehabilitation is critical to long-term recovery. Unless contraindicated, bisphosphonate therapy should be used to reduce the risk of another hip fracture. Some patients may benefit from a fall-prevention assessment.

  10. Dynamic Hip Screw Compared to Condylar Blade Plate in the Treatment of Unstable Fragility Intertrochanteric Fractures

    Directory of Open Access Journals (Sweden)

    CK Yong

    2009-05-01

    Full Text Available Dynamic hip screw (DHS fixation is considered standard treatment for most intertrochanteric fractures. However, excessive sliding at the fracture site and medialisation of femoral shaft may lead in fixation failure. In contrast, fixed- angled 95° condylar blade plate (CBP has no effective dynamic capacity and causes little bone loss compared to DHS. We compared the outcome of 57consecutive unstable intertrochanteric fragility fractures treated with these two fixation methods. CBP instrumentation is more difficult requiring longer incision, operating time and higher surgeon- reported operative difficulty. The six month post-operative mortality rate is 16%. Post-operative Harris hip scores were comparable between the two methods. Limb length shortening more than 20 mm was 6-fold more common with DHS. In elderly patients with unstable intertrochanteric fragility fractures, fixed angled condylar blade plate appears to be a better choice than dynamic hip screws for preventing fixation failures.

  11. Pressure ulcer risk in hip fracture patients

    NARCIS (Netherlands)

    Houwing, RH; Rozendaal, M; Wouters-Wesseling, W; Buskens, E; Keller, P; Haalboom, JRE

    2004-01-01

    Hip fracture patients have a high risk of pressure ulcers (PU). We followed 121 hip fracture patients for the development of pressure ulcers and evaluated a risk assessment tool for sensitivity and specificity. More than half of the patients presented with PU, mostly stage I. Risk factors for PU wer

  12. Pressure ulcer risk in hip fracture patients

    NARCIS (Netherlands)

    Houwing, R. H.; Rozendaal, M; Wouters-Wesseling, W; Buskens, E.; Keller, P; Haalboom, JRE

    Hip fracture patients have a high risk of pressure ulcers (PU). We followed 121 hip fracture patients for the development of pressure ulcers and evaluated a risk assessment tool for sensitivity and specificity. More than half of the patients presented with PU, mostly stage I. Risk factors for PU

  13. External fixation for phalangeal and metacarpal fractures

    NARCIS (Netherlands)

    Drenth, DJ; Klasen, HJ

    From 1987 to 1993 we treated 33 patients with 29 phalangeal and seven metacarpal fractures by external fixation using a mini-Hoffmann device. There were 27 open and 25 comminuted fractures, In 12 patients one or more tendons was involved, The mean follow-up was 4.4 years, Complications occurred in

  14. Factors Affecting Postsurgery Hip Fracture Recovery

    Directory of Open Access Journals (Sweden)

    Sydney Wallace

    2014-12-01

    Full Text Available After hip fracture surgery, patients seldom return to their prefracture functional state and there is a 43% rate of mortality and institutionalisation of postsurgery hip fracture patients. A systematic literature review was conducted to identify preoperative, perioperative, postoperative, and psychosocial factors that may hinder postsurgery hip fracture patients from returning to previous functionality. Factors that were identified as being associated with postsurgical outcomes were age, muscle strength, prefracture living arrangements, number of daily medications taken, oxygen levels, fracture type and location, haemoglobin (Hb level, wait time prior to surgery, length of hospital stay (LOS, and dementia or depression.

  15. 全髋关节置换与空心螺钉置入内固定修复中老年股骨颈骨折:髋关节功能比较%Total hip arthroplasty versus hollow screw fixation for the repair of femoral neck fractures in the middle-aged and elder patients:hip function

    Institute of Scientific and Technical Information of China (English)

    林庆波

    2015-01-01

    BACKGROUND:The repair method of femoral neck fractures included internal fixation and hip arthroplasty. The selection of repair methods is affected by many factors, such as age, condition of patients, and own physical condition. The selection of repair methods for femoral neck fractures is always controversial. OBJECTIVE:To compare the hip function and prognosis of elderly patients with femoral neck fractures after total hip arthroplasty and hol ow screw fixation. METHODS:140 patients aged less than 60 years, who accepted treatment in Rizhao Hospital of Traditional Chinese Medicine from April 2012 to February 2014, were selected. They were randomly divided into replacement group and fixation group (n=70). Patients in the replacement group received total hip arthroplasty, and patients in the fixation group received hol ow compression screw fixation. Harris score of the hip, complications and satisfactions of the hip were observed, compared and analyzed between the two groups at 1 month post surgery. RESULTS AND CONCLUSION:The excel ent and good rate of Harris score at 1 month post surgery was significantly higher in the replacement group (90%) than in the fixation group (63%) (P  目的:对比中老年股骨颈骨折患者行全髋关节置换与空心螺钉置入内固定治疗后的髋关节功能及预后。  方法:选取2012年4月至2014年2月日照市中医医院收治的140例股骨颈骨折患者,年龄小于60岁,随机分为置换组和内固定组,每组70例。置换组采用全髋关节置换治疗,内固定组患者采取空心加压螺钉置入内固定治疗。观察两组患者治疗后1个月的髋关节功能Harris评分、并发症发生情况及关节功能满意度,并进行对比分析。  结果与结论:治疗后1个月,置换组Harris评分的优良率为90%,明显高于内固定组63%,差异有显著性意义(P<0.05);置换组并发症发生率为6%,明显低于内固定组29%

  16. Rib Fracture Fixation: Indications and Outcomes.

    Science.gov (United States)

    Senekjian, Lara; Nirula, Raminder

    2017-01-01

    Rib fractures are a frequently identified injury in the trauma population. Not only are multiple rib fractures painful, but they are associated with an increased risk of adverse outcomes. Pneumonia in particular can be devastating, especially to an elderly patient, but other complications such as prolonged ventilation and increased intensive care and hospital durations of stay have a negative impact on the patient. Computed tomography scan is the best modality to diagnosis rib fractures but the treatment of fractures is still evolving. Currently patient care involves a multidisciplinary approach that includes pain control, aggressive pulmonary therapy, and possibly surgical fixation. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Hip and pelvic fractures and sciatic nerve injury

    Institute of Scientific and Technical Information of China (English)

    蒋电明; 余学东; 安洪; 梁勇; 梁安霖

    2002-01-01

    Objective: To investigate the influence of hip and pelvic fracture, especially acetabular fracture complicated by sciatic nerve injury on clinical features and prognosis of sciatic nerve injury. Methods: From January 1987 to January 2000, 17 patients (14 male and 3 female) who had hip and pelvic fractures complicated by sciatic nerve injury were treated with operative reduction and internal fixation and followed up from 10 months to 5 years. The average age was 38 years (ranging 23-56 years). The left extremities were involved in 11 patients and the right in 6. Twelve patients underwent primary exploration and neurolysis and 5 patients underwent secondary operation. Results: Preoperatively, 8 patients were treated with large doses of oral narcotics to control their severe sciatic pain. Three of the 8 patients underwent patient-controlled analgesia and epidural analgesia. After operation, excellent and good rates of reduction and functional recovery of sciatic nerve were 94.1% and 88% respectively. Four patients still had sciatic pain and 2 patients failed to recover. Sciatic nerve function improved within 3-6 months after surgery in 11 patients. Conclusions: Hip and pelvic fractures can result in sciatic nerve injury, especially common peroneal nerve injury and prognosis is poor. Open reduction and internal fixation combined with nerve exploration and neurolysis should be used as early as possible for severe sciatic pain.

  18. Celiac Disease in Women with Hip Fractures

    Science.gov (United States)

    LeBoff, Meryl S.; Cobb, Haley; Gao, Lisa Y.; Hawkes, William; Yu-Yahiro, Janet; Kolatkar, Nikheel S.; Magaziner, Jay

    2014-01-01

    Objective Celiac disease is associated with decreased bone density, however, the risk of fractures in celiac disease patients is unclear. We compared the prevalence of celiac disease between a group of women with hip fractures and a group of women undergoing elective joint replacement surgery and the association between celiac disease and vitamin D levels. Methods Two hundred eight community dwelling and postmenopausal women were recruited from Boston, MA (n=81) and Baltimore, MD (n=127). We measured tissue transglutaminase IgA by ELISA to diagnose celiac disease and 25-hydroxyvitamin D (25(OH)D) levels by radioimmunoassay in both women with hip fractures (n=157) and the control group (n=51), all of whom were from Boston. Subjects were excluded if they took any medications or had medical conditions that might affect bone. Results Median serum 25(OH)D levels were significantly lower (p< 0.0001) in the hip fracture cohorts compared to the elective joint replacement cohort (14.1 ng/ml vs. 21.3 ng/ml, respectively). There were no differences in the percentage of subjects with a positive tissue transglutaminase in the women with hip fractures versus the control group (1.91% vs. 1.61%, respectively). Conclusion Vitamin D levels are markedly reduced in women with hip fractures, however hip fracture patients did not show a higher percentage of positive tissue transglutaminase levels compared with controls. These data suggest that routine testing for celiac disease among hip fracture patients may not prove useful, although larger prospective studies among hip fracture subjects are needed. PMID:23732553

  19. Epidemiology of hip fracture: Worldwide geographic variation

    Directory of Open Access Journals (Sweden)

    Dinesh K Dhanwal

    2011-01-01

    Full Text Available Osteoporosis is a major health problem, especially in elderly populations, and is associated with fragility fractures at the hip, spine, and wrist. Hip fracture contributes to both morbidity and mortality in the elderly. The demographics of world populations are set to change, with more elderly living in developing countries, and it has been estimated that by 2050 half of hip fractures will occur in Asia. This review conducted using the PubMed database describes the incidence of hip fracture in different regions of the world and discusses the possible causes of this wide geographic variation. The analysis of data from different studies show a wide geographic variation across the world, with higher hip fracture incidence reported from industrialized countries as compared to developing countries. The highest hip fracture rates are seen in North Europe and the US and lowest in Latin America and Africa. Asian countries such as Kuwait, Iran, China, and Hong Kong show intermediate hip fracture rates. There is also a north-south gradient seen in European studies, and more fractures are seen in the north of the US than in the south. The factors responsible of this variation are population demographics (with more elderly living in countries with higher incidence rates and the influence of ethnicity, latitude, and environmental factors. The understanding of this changing geographic variation will help policy makers to develop strategies to reduce the burden of hip fractures in developing countries such as India, which will face the brunt of this problem over the coming decades.

  20. Intraoperative Periprosthetic Femur Fracture: A Biomechanical Analysis of Cerclage Fixation.

    Science.gov (United States)

    Frisch, Nicholas B; Charters, Michael A; Sikora-Klak, Jakub; Banglmaier, Richard F; Oravec, Daniel J; Silverton, Craig D

    2015-08-01

    Intraoperative periprosthetic femur fracture is a known complication of total hip arthroplasty (THA) and a variety of cerclage systems are available to manage these fractures. The purpose of this study was to examine the in situ biomechanical response of cerclage systems for fixation of periprosthetic femur fractures that occur during cementless THA. We compared cobalt chrome (CoCr) cables, synthetic cables, monofilament wires and hose clamps under axial compressive and torsional loading. Metallic constructs with a positive locking system performed the best, supporting the highest loads with minimal implant subsidence (both axial and angular) after loading. Overall, the CoCr cable and hose clamp had the highest construct stiffness and least reduction in stiffness with increased loading. They were not demonstrably different from each other. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Neck of femur fracture fixation in a bilateral amputee: an uncommon condition requiring an improvised fracture table positioning technique.

    Science.gov (United States)

    Berg, Andrew James; Bhatia, Chandra

    2014-02-21

    While neck of femur fractures are common it is rare to see this injury in a bilateral leg amputee. Special consideration needs to be given to the management of these patients. We report the case of a 58-year-old man with bilateral leg amputation who presented to the emergency department with left hip pain following a fall. A fracture of the left neck of femur with extension into the femoral shaft was diagnosed. Internal fixation was planned with a dynamic hip screw. Standard fracture table setup, which allows for traction of the fractured limb and positioning of the contralateral limb such that anteroposterior and lateral X-rays can be obtained, was not possible in this case due to the amputations. We highlight considerations that need to be made in positioning a bilateral amputee for neck of femur fracture fixation and also highlight an improvised technique that can be utilised by other surgeons.

  2. Primary total hip arthroplasty for acetabular fracture

    Institute of Scientific and Technical Information of China (English)

    WANG Zi-ming; SUN Hong-zhen; WANG Ai-min; DU Quan-yin; WU Siyu; ZHAO Yu-feng; TANG Ying

    2006-01-01

    Objective: To explore the operative indications and operative methods of primary total hip arthroplasty for acetabular fracture and to observe the clinical curative effect.Methods: We retrospectively summarized and analyzed the traumatic conditions, fracture types, complications,operative time, operative techniques, and short-term curative effect of 11 patients( 10 males and 1 female, with a mean age of 42. 4 years ) with acetabular fracture who underwent primary total hip arthroplasty.Results: The patients were followed up for 6-45 months ( mean = 28 months). Their average Harris score of postoperative hip joint was 78.Conclusion: Under strict mastery of indications,patients with acetabular fracture may undergo primary total hip arthroplasty, but stable acetabular components should be made.

  3. A new algorithm for hip fracture surgery

    DEFF Research Database (Denmark)

    Palm, Henrik; Krasheninnikoff, Michael; Holck, Kim

    2012-01-01

    Background and purpose Treatment of hip fracture patients is controversial. We implemented a new operative and supervision algorithm (the Hvidovre algorithm) for surgical treatment of all hip fractures, primarily based on own previously published results. Methods 2,000 consecutive patients over 50...... years of age who were admitted and operated on because of a hip fracture were prospectively included. 1,000 of these patients were included after implementation of the algorithm. Demographic parameters, hospital treatment, and reoperations within the first postoperative year were assessed from patient...... by reoperations was reduced from 24% of total hospitalization before the algorithm was introduced to 18% after it was introduced. Interpretation It is possible to implement an algorithm for treatment of all hip fracture patients in a large teaching hospital. In our case, the Hvidovre algorithm both raised...

  4. Ipsilateral Traumatic Posterior Hip Dislocation, Posterior Wall and Transverse Acetabular Fracture with Trochanteric Fracture in an adult: Report of First Case

    Directory of Open Access Journals (Sweden)

    Skand Sinha

    2013-10-01

    Full Text Available Introduction: Posterior dislocation of the hip joint with associated acetabular and intertrochanteric fracture is a complex injury. Early recognition, prompt and stable reduction is needed of successful outcome. Case Report: 45 year old male patient presented with posterior dislocation of the hip with transverse fracture with posterior wall fracture of acetabulam and intertrochanteric fracture on the ipsilateral side. The complex fracture geometry was confirmed by CT scan. The patient was successfully managed by open reduction and internal fixation of intertrochanteric fracture was achieved with dynamic hip screw (DHS plate fixation followed by fixation of acetabular fracture with reconstruction plate. Conclusion: Hip dislocation combined with acetabular fracture is an uncommon injury; this article presents a unique case of posterior wall and transverse fractures of ipsilateral acetabulum with intertrochanteric fracture in a patient who sustained traumatic posterior hip dislocation. Early surgical intervention is important for satisfactory outcomes of such complex fracture-dislocation injuries. Keywords: Hip dislocation; acetabular fractures; intertrochanteric fracture; operative treatment.

  5. Hip Fracture Prevention: Cost-Effective Strategies

    OpenAIRE

    Peter Vestergaard; Lars Rejnmark; Leif Mosekilde

    2001-01-01

    The available literature on cost benefit, cost effectiveness and cost utility of different drug and non-drug regimens in preventing hip fractures was reviewed. The cost of a hip fracture and of the different treatment regimens varied considerably from one country to another. In primary prevention, potential savings only exceeded costs in women over the age of 70 years treated with hormonal replacement therapy (HRT). In the case of HRT, treating those with low bone mineral density levels (seco...

  6. Locking plate fixation for proximal humerus fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2012-02-01

    Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for proximal humeral fractures should involve minimal soft tissue dissection and achieve anatomic reduction of the head complex with sufficient stability to allow for early shoulder mobilization. This article reviews various treatment options, in particular locking plate fixation. Locking plate fixation is associated with a high complication rate, such as avascular necrosis (7.9%), screw cutout (11.6%), and revision surgery (13.7%). These complications are frequently due to the varus deformation of the humeral head. Strategic screw placement in the humeral head would minimize the possibility of loss of fracture reduction and potential hardware complications. Locking plate fixation is a good surgical option for the management of proximal humerus fractures. Complications can be avoided by using better bone stock and by careful screw placement in the humeral head.

  7. Cable plates and onlay allografts in periprosthetic femoral fractures after hip replacement: laboratory and clinical observations.

    Science.gov (United States)

    Howell, Jonathan R; Masri, Bassam A; Garbuz, Donald S; Greidanus, Nelson V; Duncan, Clive P

    2004-01-01

    Fractures of the femur after total hip replacement are an increasingly common and technically challenging problem. The results of nonsurgical treatment are poor. When the general condition of the patient allows, these injuries should be treated surgically. Several surgical treatments can be used to treat these fractures, and classification of the fracture assists the surgeon in the choice of procedure. Over the past decade, cable plate fixation systems and onlay strut allografts have become two of the most commonly used methods of fixation for fractures associated with hip prostheses. The ideal method of fixation is yet to be determined. However, laboratory studies have shown that dual fixation using either a lateral plate and anterior strut graft or two strut grafts produces the strongest construct. Cables rather than smooth wires should be used for fixation, and fixation strength increases with the number of cables used. The use of screws proximally produces a strong fixation but there are theoretical disadvantages to using screws around a femoral implant. Clinical data show high rates of fracture union using cable plate fixation, cortical onlay allograft fixation, and combined fixation methods for fractures that occur around well-fixed implants. Results have been less encouraging when these techniques have been used to fix fractures around prostheses that are either loose or malaligned; such fractures are better managed by revision of the femoral component to a long-stemmed device. Care should also be taken when there has been previous periosteal stripping of the femur because this may predispose to fracture nonunion. Periprosthetic fractures of the femur are a complex surgical problem and require specialized training in a range of surgical techniques.

  8. Management of osteoporosis in patients hospitalized for hip fractures

    OpenAIRE

    Ip, T. P.; Leung, J.; Kung, A. W. C.

    2010-01-01

    Hip fracture is associated with high morbidity, mortality, and economic burden worldwide. It is also a major risk factor for a subsequent fracture. A literature search on the management of osteoporosis in patients with hip fracture was performed on the Medline database. Only one clinical drug trial was conducted in patients with a recent hip fracture. Further studies that specifically address post-fracture management of hip fracture are needed. The efficacy of anti-osteoporosis medication in ...

  9. [Hip Fracture--Epidemiology, Management and Liaison Service. Risk factor for hip fracture].

    Science.gov (United States)

    Fujiwara, Saeko

    2015-04-01

    Many risk factors have been identified for hip fracture, including female, advanced age, osteoporosis, previous fractures, low body weight or low body mass index, alcohol drinking, smoking, family history of fractures, use of glucocorticoid, factors related to falls, and bone strength. The factors related to falls are number of fall, frail, post stroke, paralysis, muscle weakness, anti-anxiety drugs, anti-depression drugs, and sedatives. Dementia and respiratory disease and others have been reported to be risk factors for secondary hip fracture.

  10. Arthrofibrosis After Periarticular Fracture Fixation.

    Science.gov (United States)

    McAlister, Ian; Sems, Stephen Andrew

    2016-04-01

    Arthrofibrosis after periarticular fractures can create clinically significant impairments in both the upper and lower extremities. The shoulder, elbow, and knee are particularly susceptible to the condition. Many risk factors for the development of arthrofibrosis cannot be controlled by the patient or surgeon. Early postoperative motion should be promoted whenever possible. Manipulations under anesthesia are effective for a period of time in certain fracture patterns, and open or arthroscopic surgical debridements should be reserved for the patient for whom nonoperative modalities fail and who has a clinically significant deficit. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Femoral head fracture without hip dislocation

    Institute of Scientific and Technical Information of China (English)

    Aditya K Aggarwal; Ashwani Soni; Daljeet Singh

    2013-01-01

    Femoral head fractures without dislocation or subluxation are extremely rare injuries.We report a neglected case of isolated comminuted fracture of femoral head without hip dislocation or subluxation of one year duration in a 36-year-old patient who sustained a high energy trauma due to road traffic accident.He presented with painful right hip and inability to bear full weight on right lower limb with Harris hip score of 39.He received cementless total hip replacement.At latest follow-up of 2.3 years,functional outcome was excellent with Harris hip score of 95.Such isolated injuries have been described only once in the literature and have not been classified till now.The purpose of this report is to highlight the extreme rarity,possible mechanism involved and a novel classification system to classify such injuries.

  12. Hip fracture in hospitalized medical patients.

    Science.gov (United States)

    Zapatero, Antonio; Barba, Raquel; Canora, Jesús; Losa, Juan E; Plaza, Susana; San Roman, Jesús; Marco, Javier

    2013-01-08

    The aim of the present study is to analyze the incidence of hip fracture as a complication of admissions to internal medicine units in Spain. We analyzed the clinical data of 2,134,363 adults who had been admitted to internal medicine wards. The main outcome was a diagnosis of hip fracture during hospitalization.Outcome measures included rates of in-hospital fractures, length of stay and cost. A total of 1127 (0.057%) admittances were coded with an in-hospital hip fracture. In hospital mortality rate was 27.9% vs 9.4%; p patients with a hip fracture (20.7 days vs 9.8 days; p patients (6927€ per hospitalization vs 3730€ in non fracture patients). Risk factors related to fracture were: increasing age by 10 years increments (OR 2.32 95% CI 2.11-2.56), female gender (OR 1.22 95% CI 1.08-1.37), admission from nursing home (OR 1.65 95% CI 1.27-2.12), dementia (1.55 OR 95% CI1.30-1.84), malnutrition (OR 2.50 95% CI 1.88-3.32), delirium (OR 1.57 95% CI 1.16-2.14), and anemia (OR 1.30 95%CI 1.12-1.49). In-hospital hip fracture notably increased mortality during hospitalization, doubling the mean length of stay and mean cost of admission. These are reasons enough to stress the importance of designing and applying multidisciplinary plans focused on reducing the incidence of hip fractures in hospitalized patients.

  13. Risk factors for deep vein thrombosis in lower extremity after hip or knee arthroplasty and hip fracture internal fixation%髋、膝关节矫形术和髋部骨折内固定术后病人下肢深静脉血栓形成的危险因素

    Institute of Scientific and Technical Information of China (English)

    宋琳琳; 吴新民; 袁训芝; 袁家颖; 赵国立

    2008-01-01

    目的 分析髋、膝关节矫形术和髋部骨折内固定术后病人下肢深静脉血栓形成(DVT)的危险因素.方法 2004年至2005年接受髋、膝关节矫形术和髋部骨折内固定术的病人147例,年龄33~92岁.术后2周行双侧下肢静脉Duplex彩色超声检查,观察DVT形成的情况,根据是否形成DVT,分为非DVT组和DVT组.记录围术期有关病人、手术和麻醉方面的临床资料.结果 术后下肢DVT发生率42.2%,而近端DVT发生率2.7%.与非DVT组相比,DVT组麻黄碱使用率及其用量增加,麻醉时间延长,术后1 d白细胞计数及术后最高白细胞计数明显升高(P<0.05);logistic回归分析结果显示,上述因素与下肢DVT有关(P<0.05).结论 髋、膝关节矫形和髋部骨折内固定术后病人下肢DVT的危险因素为麻醉时间>3 h、使用麻黄碱及术后白细胞计数明显升高.%Objective To determine the factors which contribute to development of deep vein thrombosis (DVT)in lower extremity in patients after hip or knee arthroplasty and hip fracture internal Fixation.Methods One hundred forty seven consecutive patients receiving hip or knee arthroplasty and hip fracture internal fixation from 2004 to 2005 were included in this study.Their age ranged from 33 to 92 yr.Bilateral lower extremity vein Duplex color ultrasound was performed before and 2 weeks after operation for detection of DvT.The patients were divided into DVT and DVT-free groups based on the development of DVT after operation.Detailed perioperative clinical information about the patients,surgery and anesthesia was collected.Results Lower extremity DVT was found in 42.2% of the patients after operation.The incidence of proximal DVT was 2.7%.The rate of ephedrine administration was significantly higher and the amount of ephedrine given was larger in DVT group than in DVT-free group.Duration of anesthesia was significantly longer and WBC count on the 1st postoperative day was significantly higher in DVT

  14. Zoledronic acid and clinical fractures and mortality after hip fracture

    DEFF Research Database (Denmark)

    Lyles, Kenneth W; Colón-Emeric, Cathleen S; Magaziner, Jay S

    2007-01-01

    BACKGROUND: Mortality is increased after a hip fracture, and strategies that improve outcomes are needed. METHODS: In this randomized, double-blind, placebo-controlled trial, 1065 patients were assigned to receive yearly intravenous zoledronic acid (at a dose of 5 mg), and 1062 patients were...... assigned to receive placebo. The infusions were first administered within 90 days after surgical repair of a hip fracture. All patients (mean age, 74.5 years) received supplemental vitamin D and calcium. The median follow-up was 1.9 years. The primary end point was a new clinical fracture. RESULTS...... in the two groups. CONCLUSIONS: An annual infusion of zoledronic acid within 90 days after repair of a low-trauma hip fracture was associated with a reduction in the rate of new clinical fractures and with improved survival. (ClinicalTrials.gov number, NCT00046254 [ClinicalTrials.gov].)....

  15. Role of MRI in hip fractures, including stress fractures, occult fractures, avulsion fractures

    Energy Technology Data Exchange (ETDEWEB)

    Nachtrab, O. [Department of Radiology, The Robert Jones and Agnes Hunt Orthopaedic Hospital, Gobowen, Oswestry Shropshire SY10 7AG (United Kingdom); Cassar-Pullicino, V.N., E-mail: Victor.Pullicino@rjah.nhs.uk [Department of Radiology, The Robert Jones and Agnes Hunt Orthopaedic Hospital, Gobowen, Oswestry Shropshire SY10 7AG (United Kingdom); Lalam, R.; Tins, B.; Tyrrell, P.N.M.; Singh, J. [Department of Radiology, The Robert Jones and Agnes Hunt Orthopaedic Hospital, Gobowen, Oswestry Shropshire SY10 7AG (United Kingdom)

    2012-12-15

    MR imaging plays a vital role in the diagnosis and management of hip fractures in all age groups, in a large spectrum of patient groups spanning the elderly and sporting population. It allows a confident exclusion of fracture, differentiation of bony from soft tissue injury and an early confident detection of fractures. There is a spectrum of MR findings which in part is dictated by the type and cause of the fracture which the radiologist needs to be familiar with. Judicious but prompt utilisation of MR in patients with suspected hip fractures has a positive therapeutic impact with healthcare cost benefits as well as social care benefits.

  16. Periprosthetic fracture of the acetabulum after total hip arthroplasty.

    Science.gov (United States)

    Peterson, C A; Lewallen, D G

    1996-08-01

    Eleven patients who had sustained a periprosthetic fracture of the acetabulum at a mean of 6.2 years (range, one month to thirteen years) after a total hip arthroplasty were managed at our institution between 1985 and 1991. Five patients had a fracture of the medial wall; three, a fracture of the posterior column; two, a transverse fracture; and one, a fracture of the anterior column. Six fractures were displaced by two millimeters or more. Eight fractures were caused by blunt trauma or a fall, and three occurred spontaneously. A fracture was classified as type 1 if the acetabular component was clinically and radiographically stable (eight patients) and as type 2 if the component was unstable (three patients). One patient, who had a displaced type-2 fracture of the posterior column, died of an associated intrapelvic vascular injury. The other two patients who had a type-2 fracture were managed with revision of the acetabular component without supplemental plate fixation, immediately after the diagnosis of the fracture. The eight patients who had a type-1 fracture initially were managed with limitation of weight-bearing or modification of activity; in six of these patients, the fracture united without additional treatment. The ten surviving patients were followed for a mean of sixty-two months after the fracture. Eight of these patients-including four in whom a type-1 fracture had united after non-operative treatment-had a revision of the acetabular component because of pain, loosening, or non-union by the time of the most recent follow-up. Two patients (one of whom had a type-1 fracture and the other, a type-2 fracture) had multiple revisions of the acetabular component; both had supplemental internal fixation with a plate. All ten patients ultimately had a stable, functioning prosthesis. We conclude that periprosthetic acetabular fractures are associated with a poor prognosis with regard to the survival of the acetabular component but that it is possible to

  17. Stabilization of an acetabular fracture with cables for acute total hip arthroplasty.

    Science.gov (United States)

    Mears, D C; Shirahama, M

    1998-01-01

    A critical stage of total hip arthroplasty for an acute acetabular fracture where extensive comminution, impaction, and osteopenia thwart the application of conventional open or closed methods, especially in the elderly, is stable fixation of the acetabulum. The use of 2-mm braided cables permits effective immobilization of the fracture for use in conjunction with a hybrid arthroplasty. The method is consistent with the use of a conventional arthroplastic incision and is suitable for other applications including the fixation of periprosthetic fractures, bulk allografts, and conventional acetabular fractures.

  18. [Clinical pathway for hip fracture patients].

    Science.gov (United States)

    Sáez López, Pilar; Sánchez Hernández, Natalia; Paniagua Tejo, Sonsoles; Valverde García, José Antonio; Montero Díaz, Margarita; Alonso García, Noelia; Freites Esteve, Alfonso

    2015-01-01

    Hip fracture in the elderly often occurs in patients with high co-morbidity. Effective management requires a comprehensive and multidisciplinary approach. To evaluate the effect of a quality improvement intervention in the detection and treatment of complications in elderly patients admitted for hip fracture. A comparative study was conducted between two groups of patients admitted for hip fracture prior to 2010, and after a quality improvement intervention in 2013. The intervention consisted of implementing improved multidisciplinary measures in accordance with recent scientific evidence. The degree of compliance of the implemented measures was quantified. Patients admitted due to hip fracture in 2010 (216 patients) and 2013 (196 patients) were similar in age, sex, Barthel Index, and a reduced Charlson Index, although there were more comorbidities in 2013. After implementation of the protocols, the detection of delirium, malnutrition, anemia, and electrolyte disturbances increased. A larger number of patients in 2013 were precribed intravenous iron (24% more) and osteoporosis treatment (61.3% more). The average stay was reduced by 45.3% and surgical delay by 29.4%, achieving better functional efficiency. The implementation of a clinical pathway in geriatric patients with hip fracture is useful to detect and treat complications at an early stage, and to reduce pre-operative and overall stay, all without a negative clinical or functional impact. Copyright © 2014 SEGG. Published by Elsevier Espana. All rights reserved.

  19. Fascia iliaca block associated only with deep sedation in high-risk patients, taking P2Y12 receptor inhibitors, for intramedullary femoral fixation in intertrochanteric hip fracture: a series of 3 cases.

    Science.gov (United States)

    Almeida, Carlos Rodrigues; Francisco, Emília Milheiro; Pinho-Oliveira, Vítor; Assunção, José Pedro

    2016-12-01

    We present a series of 3 cases in which the impact in outcome was, first of all, related to the capacity to offer early and safer treatment to some hip fracture high-risk patients using a fascia iliaca block (FIB; ropivacaine 0,5% 20 cc and mepivacaine 1,3% 15 cc, given 30 minutes before incision) associated only with deep sedation, contributing to better practice and outcome. All elderly patients were American Society of Anesthesiologists IV patients, under P2Y12 receptor inhibitors, suffering from an intertrochanteric fracture, and purposed for intramedullary femoral fixation (IMF). All patients have been managed successfully through a deep sedation using a low-dose infusion of propofol and bolus of fentanyl without face mask ventilation, supraglottic device placement, or endotracheal intubation after an FIB. Bispectral index was always greater than 75, and no CO2 retention or respiratory depression was present. No signs of pain or hemodynamic instability were observed. In these cases, surgery would be postponed if the choice was neuroaxial anesthesia, particularly because of P2Y12 receptor inhibitors' effect. FIB puncture site is distal to the fracture and incision site, but proximal local anesthetic migration through the interfascial planes allows for constant block of femoral nerve and lateral cutaneous of femur nerve and, less constantly, block of obturator. FIB may reduce the risk of perineural hematoma associated with several injections in nerve vicinity of different lumbar plexus branches. Frequently, indications for extramedullary or IMF are overlapping, but IMF is associated with less blood loss and may be managed using a low anesthetic depth if an FIB is done, increasing safety. This way, these less invasive surgical techniques combined with an adjusted anesthetic technique may have a crucial role in high-risk patients, particularly if taking P2Y12 receptor inhibitors. In these cases of IMF, surgical manipulation of sciatic and/or inferior subcostal

  20. Dynamic condylar screw or hip joint(spanning)external fixator for treatment of pathological fractures of femoral neck and trochanter secondary to benign lesions

    Institute of Scientific and Technical Information of China (English)

    ZHANG Chun-lin; ZENG Bing-fang; DONG Yang; Daria brooks Terrell; Martin M.Malawer

    2008-01-01

    @@ The treatment of pathological fractures of the femoral neck and trochanteric region secondary to benign lesions can be a challenge for orthopaedic surgeons because of the size and nature of the lesions,the resulting bony defect,the risk of recurrence,the possible associated defortuities,and the risk of osteonecrosis.

  1. Zoledronic acid and clinical fractures and mortality after hip fracture

    DEFF Research Database (Denmark)

    Lyles, Kenneth W; Colón-Emeric, Cathleen S; Magaziner, Jay S

    2007-01-01

    BACKGROUND: Mortality is increased after a hip fracture, and strategies that improve outcomes are needed. METHODS: In this randomized, double-blind, placebo-controlled trial, 1065 patients were assigned to receive yearly intravenous zoledronic acid (at a dose of 5 mg), and 1062 patients were...... assigned to receive placebo. The infusions were first administered within 90 days after surgical repair of a hip fracture. All patients (mean age, 74.5 years) received supplemental vitamin D and calcium. The median follow-up was 1.9 years. The primary end point was a new clinical fracture. RESULTS......: The rates of any new clinical fracture were 8.6% in the zoledronic acid group and 13.9% in the placebo group, a 35% risk reduction with zoledronic acid (P=0.001); the respective rates of a new clinical vertebral fracture were 1.7% and 3.8% (P=0.02), and the respective rates of new nonvertebral fractures...

  2. Total Hip Arthroplasty in Failed Hip Fractures: A Case Series

    Directory of Open Access Journals (Sweden)

    Syed Shahid Noor

    2015-01-01

    Full Text Available Osteoporosis is epidemic in Asian countries. It is a major cause of fractures that orthopaedic surgeons deal in Pakistan, though proper epidemiological data is not available. Habiba U et al found that 75.3% of post menopausal women of Pakistan were predisposed to Osteoporosis; whereas Baig L has described an average T - score of -1.833±0.65 on bone mineral density calculation of post menopausal females of Pakistan. Osteoporotic hip fractures constitute a major cause of elderly mortality worldwide and recent figures supporting the idea that these patients have survival rates comparable to breast and thyroid cancer patients. Pakistan is a developing country with large burden of hip fractures. Patients living in remote areas are the ones which suffer more because of inadequate awareness, fear of surgical treatment and lack of availability of standard treatment. These patients are dealt by surgeons of various expertise and levels of experience. Lack of facilities in hospitals is well known and usage of sub-standard implant is a major cause of failure. Therefore these patients either because of their bone fragility or mal-treatment suffer frequently from failure of hip fracture surgeries. Being in a tertiary care centre we come across these types of cases very frequently. Six to eight such cases present to outpatient department of Liaquat National Hospital every month being referred from every part of the country. These patients may have been operated once, twice or even multiple times. Special attention is required to acquire an informative history from these cases and perform a comprehensive examination. Moreover previous records and radiographs provide invaluable information regarding cause of failure and deciding course of further treatment. We herein discuss few of the cases of failure of hip fractures which were treated by hip arthroplasty.

  3. Periprosthetic fractures in the resurfaced hip--A case report and review of the literature.

    LENUS (Irish Health Repository)

    Brennan, Stephen A

    2013-02-01

    Traumatic periprosthetic fractures adjacent a hip resurfacing prosthesis are rare. When proximal fractures are encountered the obvious surgical solution is to revise to a large head stemmed femoral component. A previously well functioning implant may however be retained as various non-operative and operative treatment options exist. This paper reports the case history of a traumatic periprosthetic fracture successfully treated with cannulated screw fixation and reviews the current literature.

  4. Ipsilateral fracture dislocations of the hip and knee joints with contralateral open fracture of the leg: a rare case and its management principles

    Directory of Open Access Journals (Sweden)

    Sen Ramesh Kumar

    2011-06-01

    Full Text Available 【Abstract】This paper discussed the injury mecha- nism and management of a patient who had concomitant ipsilateral hip and knee dislocations and contralateral open leg fracture. A 32-year-old man presented with ipsilateral fracture- dislocations of the left hip (Pipkin’s type IV and knee (Moore II joints and contralateral open fracture of the leg bones after a car accident. After emergency resuscitative measures, the hip joint was reduced and Pipkin’s fracture was fixed using Ganz approach with lag screws; knee joint was reduced closely and tibial plateau fracture was stabi- lized with lateral buttress plate and a transarticular span- ning fixator. The open fracture on the other leg was de- brided and fixed with an external fixator. There was no insta- bility in both joints after fixation when he was examined under anesthesia. The fractures united after 3 months and the patient had no residual instability of hip and knee. There was no clinical or radiological evidence of osteonecrosis in the hip joint after 6 months. At one-year follow-up, he had satisfactory functional outcome with almost normal range of motion at both joints. Ipsilateral hip and knee dislocations are rare injuries and more caution is needed for early diagnosis. A timely appro- priate intervention can provide good functional outcome to the patient in this situation. Key words: Hip dislocation; Knee dislocation; Fractures, bone

  5. Femoral fractures : indications an[d] biomechanics of external fixation

    NARCIS (Netherlands)

    A.H. Broekhuizen (Tom); B. van Linge

    1988-01-01

    textabstractInternal fixation can be carried out in various ways. For femoral shaft fractures, an (interlocking) nail is becoming increasingly popular, instead of open realignment of the fracture. External fixation, which has become a generally accepted method of treating fractures of the lower

  6. Biomechanical Stability of Four Fixation Constructs for Distal Radius Fractures

    OpenAIRE

    Capo, John T.; Kinchelow, Tosca; Brooks, Kenneth; Tan, Virak; Manigrasso, Michaele; Francisco, Kristin

    2009-01-01

    Implants available for distal radius fracture fixation include dorsal nonlocked plating (DNLP), volar locked plating (VLP), radial–ulnar dual-column locked plating (DCPs), and locked intramedullary fixation (IMN). This study examines the biomechanical properties of these four different fixation constructs. In 28 fresh-frozen radii, a wedge osteotomy was performed, creating an unstable fracture model and the four fixation constructs employed (DNLP, VLP, DCPs, and IMN). Dorsal bending loads wer...

  7. Dynamic hip screw and Gamma nail fixation repair unstable intertrochanteric fracture:a three-dimensional finite element analysis%动力髋螺钉和Gamma钉置入固定不稳定股骨转子间骨折的三维有限元分析

    Institute of Scientific and Technical Information of China (English)

    黄晓微; 禹宝庆; 李泽湘; 敖荣广

    2015-01-01

    BACKGROUND:For unstable intertrochanteric fracture repair, there are two views:extramedul ary fixation or intramedul ary fixation. Theoretical y, intramedul ary fixation is in line with the principles of minimal y invasive, more mechanical and biological advantages. However, evidence-based medicine and related studies have shown that compared with the extramedul ary fixation, intramedul ary fixation did not reflect the proper theoretical advantage. OBJECTIVE:To compare the biomechanical performance of two kinds of internal fixation systems:dynamic hip screw and Gamma nail which commonly used in repair of intertrochanteric fractures by finite element method, and to evaluate the advantages and disadvantages of dynamic hip screw and Gamma nail in treatment of unstable intertrochanteric fracture. METHODS:Three-dimensional finite element model of human femur unstable intertrochanteric fractures (31-A2;AO fracture classification), and the three-dimensional finite element models of dynamic hip screw and Gamma nail were established respectively, and were fixed according to the requirement of orthopedic surgery. The reference load which the joint bearing was at the peak time in adult step state period with the body mass of 700 N was stimulated. The stress distribution of bone, bone-internal fixation model, nail or screw, the strain and deformation of fracture location on the surface of the bone and bone-internal fixation model, the stress distribution along the femur and the loading transfer condition along the internal fixator and the like were analyzed. RESULTS AND CONCLUSION:Dynamic hip screw and Gamma nail have good sliding compression features which could make the continuous and dynamical y axial compression of the fractured section. Under the load conditions, the displacement value of dynamic hip screw was larger. In the treatment of unstable intertrochanteric fracture, Gamma nail was stronger than dynamic hip screw. Two kinds of internal fixations al make the

  8. Mechanical Comparison of Headless Screw Fixation and Locking Plate Fixation for Talar Neck Fractures.

    Science.gov (United States)

    Karakasli, Ahmet; Hapa, Onur; Erduran, Mehmet; Dincer, Cemal; Cecen, Berivan; Havitcioglu, Hasan

    2015-01-01

    For talar neck fractures, open reduction and internal fixation have been thought to facilitate revascularization and prevent osteonecrosis. Newer screw systems allow for placement of cannulated headless screws, which provide compression by virtue of a variable pitch thread. The present study compared the biomechanical fixation strength of cannulated headless variable-pitch screw fixation and locking plate fixation. A reproducible talar neck fracture was created in 14 fresh cadaver talar necks. Talar head fixation was then performed using 2 cannulated headless variable-pitch 4-mm/5-mm diameter (4/5) screws (Acutrak; Acumed, Hillsboro, OR) and locking plate fixation. Headless variable-pitch screw fixation had lower failure displacement than did locking plate fixation. No statistically significant differences were found in failure stiffness, yield stiffness (p = .655), yield load (p = .142), or ultimate load between the 2 fixation techniques. Cannulated headless variable-pitch screw fixation resulted in better failure displacement than locking plate fixation in a cadaveric talus model and could be considered a viable option for talus fracture fixation. Headless, fully threaded, variable-pitch screw fixation has inherent advantages compared with locking plate fixation, because it might cause less damage to the articular surface and can compress the fracture for improved reduction. Additionally, plate fixation can increase the risk of avascular necrosis owing to the wider incision and dissection of soft tissues.

  9. Mortality analysis in hip fracture patients

    DEFF Research Database (Denmark)

    Foss, N B; Kehlet, H

    2005-01-01

    Patients with hip fractures are usually frail and elderly with a 30-day mortality in excess of 10% in European series. Perioperative morbidity is often multifactorial in nature, and unimodal interventions will not necessarily decrease mortality. The purpose of this prospective study was to analys...

  10. Short time-frame from first to second hip fracture in the Funen County Hip Fracture Study

    DEFF Research Database (Denmark)

    Nymark, T; Lauritsen, Jens; Ovesen, O

    2006-01-01

    Hip fracture patients represent a frail group of elderly with increased morbidity and mortality. The aim of this study was to evaluate the occurrence and distribution of a second hip fracture in the time interval between the first and the second hip fracture....

  11. The mid - and long - term clinical outcomes of open reduction and internal fixation for dislocation of hip joint combined with posterior wall or/and column fractures of acetabulum%髋关节后脱位并髋臼后壁(柱)骨折手术治疗结果分析

    Institute of Scientific and Technical Information of China (English)

    何长街; 刘志礼; 舒勇; 黄山虎

    2011-01-01

    目的 探讨髋臼后壁(柱)骨折伴髋关节脱位手术治疗的中远期疗效.方法 回顾性分析21例髋关节脱位伴髋臼骨折患者临床资料,其中20例髋臼脱位行闭合复位,1例行急诊切开复位内固定;所有合并的髋臼骨折均采用开放复位内固定术治疗.结果 完整随访19例,失访 2例,随访时间29~86个月.按髋关节功能恢复情况评分:优13例,良3例,可2例,差1例,优良率84.2%.结论 髋关节脱位伴髋臼骨折应尽早诊断,应尽快行髋关节复位,骨折应尽早开放复位内固定,早期功能锻炼,避免过早负重.%Objectives To investigate the mid - and long - term clinical outcomes of open reduction and internal fixation(ORIF) for treating the dislocation of hip joint with posterior wall or/and column fractures of acetabulum. Methods The clinic data of 21 patients with dislocation of hip joint and posterior wall fracture of acetabulum who were given close reduction( n = 20)or open reduction and internal fixation(ORIF) ( n = 1 ) for disclocation of hip joint and then were treated with ORIF for the fracture of acetabulum were retrospectively analyzed. Results A total of 19 patients were followed up for 29 to 86 mon. According to Letournel E's hip joint functional scoring system, clinical outcome was excellent in 13 patients,good in 3 patients,fair in 2 patients,and poor in one patient. The ratio of fineness of the midand long - term clinical outcomes was 84. 2%. Conclusion The dislocation of hip joint combined with posterior wall fracture of acetabulum should be diagnosed early, and reduction of the hip joint and ORIF should be performed as soon as possible. The positive functional exercise is necessary and the premature weight bearing on the hip joint should be avoided at early time.

  12. Principles of management and results of treating the fractured femur during and after total hip arthroplasty.

    Science.gov (United States)

    Greidanus, Nelson V; Mitchell, Philip A; Masri, Bassam A; Garbuz, Donald S; Duncan, Clive P

    2003-01-01

    The management of fractures of the femur during and after total hip arthroplasty can be difficult, and treatment can be fraught with complications. The ideal scenario would be one in which these fractures are prevented. It is important that the surgeon has a through understanding of the principles of managing these fractures and has access to a variety of fixation and prosthetic devices and allograft bone when necessary in order to provide the best treatment. Because periprosthetic fractures range from the very simple (requiring no surgical intervention) to the complex (requiring major revision), a classification system of these fractures aids in understanding both the principles of management and results of treatment.

  13. Surgical techniques for the fixation of trochanteric fracture compartments in hip arthroplasty for femoral intertrochanteric fractures%股骨转子间骨折人工关节置换术中转子部骨折固定技术的应用

    Institute of Scientific and Technical Information of China (English)

    储小兵; 刘富存; 童培建

    2015-01-01

    目的:探讨股骨转子间骨折人工关节置换术中转子部骨折固定的理想方式及选择依据。方法采用人工关节置换术治疗86例老年股骨转子间骨折患者。骨折按照 Evans-Jenson 分型,Ⅱ型2例,Ⅲ型22例,Ⅳ型45例,Ⅴ型17例。双极人工股骨头置换50例,全髋关节置换术36例。转子部骨折块采用金属线缆“双交叉法”捆绑固定46例,采用连接钛缆 GTR 接骨板固定技术28例,其他方法12例。结果手术成功78例,术后发生转子部骨折移位 5例(合并假体柄松动下沉 2例),关节脱位1例,假体深部感染1例,中毒性肠麻痹死亡1例。住院期间发生坠积性肺炎 2例,无坐骨神经损伤和严重的血栓栓塞并发症发生。 2例出院后失访,76例均获随访,时间3~79个月。 1例于术后2年死于急性心肌梗死,1例术后5个月死于脑溢血。末次随访时根据 Harris 髋关节功能判定标准,优52例,良13例,中9例,优良率为87.8% 。转子部骨折愈合时间3~8个月。结论老年人股骨转子间骨折采用人工关节置换治疗中,转子部骨折块的可靠固定对于术后开始进行康复训练的时间、行走步态和假体的使用寿命具有重要影响。%Objective To explore the ideal fixation techniques and selection criteria for trochanteric fracture frag-ments when treating intertrochanteric fractures of the femur by hip arthroplasty. Methods 86 cases of femoral inter-trochanteric fractures were undergone hip arthroplasties. According to Evans-Jenson classification,there were 2 cases with type Ⅱ fractures,22 with type Ⅲ,45 with type Ⅳ and 17 with type Ⅴ. 50 cases were received bipolar hemi-ar-throplasty and 36 cases were received total hip arthroplasty. Double cross binding fixation techniques with metal wires or cables were employed in 46 cases,cable-ready greater trochanteric reattachment fixation techniques in 28 cases,and other methods in 12 cases in treating femoral trochanteric

  14. Assessment of HIT Antibody Complex in Hip Fracture Patients Receiving Enoxaparin or Unfractionated Heparin

    DEFF Research Database (Denmark)

    Griffin, Justin W; Hopkinson, William J; Rud-Lassen, Michael

    2011-01-01

    Thromboembolic disease is a common complication of hip fracture in the elderly. Anticoagulants represent a standard of care in preventing postoperative thrombotic complications following surgical fixation. We asked whether levels of antibody to heparin-platelet factor 4 (PF4) complex were differe...

  15. Odontoid screw fixation for fresh and remote fractures

    Directory of Open Access Journals (Sweden)

    Rao Ganesh

    2005-01-01

    Full Text Available Fractures of the odontoid process are common, accounting for 10% to 20% of all cervical spine fractures. Odontoid process fractures are classified into three types depending on the location of the fracture line. Various treatment options are available for each of these fracture types and include application of a cervical orthosis, direct anterior screw fixation, and posterior cervical fusion. If a patient requires surgical treatment of an odontoid process fracture, the timing of treatment may affect fusion rates, particularly if direct anterior odontoid screw fixation is selected as the treatment method. For example, type II odontoid fractures treated within the first 6 months of injury with direct anterior odontoid screw fixation have an 88% fusion rate, whereas fractures treated after 18 months have only a 25% fusion rate. In this review, we discuss the etiology, biomechanics, diagnosis, and treatment (including factors affecting fusion such as timing and fracture orientation options available for odontoid process fractures.

  16. Femoral head fractures: hemiarthroplasty or total hip arthroplasty?

    Science.gov (United States)

    Ullmark, Gösta

    2014-10-02

    Most femoral neck fractures are osteoporotic fractures in the elderly. The one-year mortality after neck fracture in this group is 24%.For hemiarthroplasty (HA) the bipolar heads have a risk reduction for reoperation due to acetabular erosion compared with monoblock heads. Surprisingly, the bipolar head had an increased reoperation risk for dislocation, infection and for periprosthetic fracture.Total hip arthroplasty (THA) after fracture has a four-fold raised risk for dislocation compared with THA after osteoarthritis. A larger head on the same neck (head to neck ratio) results in a theoretically larger range of movement and hence less risk for dislocation. The dual mobility bearing has, theoretically, the largest range of movement and good clinical results.Functional results are better for THA compared with HA. Arthroplasty for fracture has much better results compared with arthroplasty after a failed internal fixation; the risk for reoperation is more than doubled for the latter.A Swedish hip arthroplasty register study found a 20-fold higher risk for periprosthetic fracture when comparing uncemented HA with matt cemented HA. Also a polished cemented stem had 13½-fold higher risks compared with a matt.The mortality during the first day after surgery is higher for cemented compared with uncemented arthroplasties, but lower after one week, one month and one year. Analysing the time points together resulted in no difference.A matt cemented THA with a maximum head size, maybe dual mobility, has the best results, and is also for the low-demanding elderly.

  17. Research on Transverse Acetabular Fracture Fixation Using Different Plate Attachment Methods

    Directory of Open Access Journals (Sweden)

    Gediminas Gaidulis

    2015-03-01

    Full Text Available The article deals with the problem of transverse acetabular fracture fixation using different plate attachment methods. A 3D model of pelvis and hip joint structure was created and the design of three different fixation plates using SolidWorks was made. The plates were fixed at distances of 10, 20 and 30 mm from the acetabulum. The model was meshed into finite elements, a static external load of 2500 N was added and the analysis of stress distribution in plates and fracture displacement was performed. The obtained results showed that fracture displacement was quite similar in all fixation methods. However, the maximal stress in the nearest from the acetabulum plate was higher than yield strength. Thus, this placement is not eligible. The plate fixed at a distance of 30 mm from the acetabulum appeared the most suitable because of the smallest and symmetrical stress distribution in the plate.

  18. Acute Stress Fracture of the Pelvis after Total Hip Arthroplasty: A Case Report.

    Science.gov (United States)

    Akinbo, Oluwaseun; Tyagi, Vineet

    2017-01-01

    Acute hip pain following total hip arthroplasty (THA) could have numerous causes to include stress fracture of the pelvis. Stress fractures of the pelvis are rare and have been reported to involve the medial wall and the pubic ramus. A unique case is presented demonstrating the clinical presentation and management of an acute stress fracture of ilium and anterior column following a THA. A 72-year-old man underwent an uncomplicated right THA. He was noted to have femoral head resorption and thin osteoporotic bone intraoperatively. He initially did well postoperatively and ambulating without pain or assistive devices. Within 1 month of surgery, he returned with acute right hip pain without any traumatic event. Radiographs showed migration of the acetabular component and computed tomography scan confirmed a fracture through the ilium. The patient underwent revision surgery, where the fracture was reduced and internal fixation was achieved with a reconstruction plate and acetabular cage construct. At 9 months postoperatively, the patient remained pain-free with full weight bearing and with stable radiographs. Elderly patients who undergo THA may have low bone mineral density. These patients can develop stress fractures in their pelvis after surgery. These fractures may involve the medial wall, posterior column, or posterior wall. In patients who develop atraumatic pain postoperatively, it is important to consider for potential stress fractures of the ilium and evaluate appropriately with imaging. In these cases, revision surgery can be necessary to provide fixation of the stress fracture.

  19. STUDY ON SPANNING EXTERNAL FIXATORS FOR PERIARTICULAR OPEN FRACTURES

    Directory of Open Access Journals (Sweden)

    Prasanth Maddila

    2017-04-01

    Full Text Available BACKGROUND Open fractures which occur close to any fracture need immobilisation for the soft tissues to heal. Some open fractures are even fixed with provisional fixations to maintain the alignment of the fractures. The provisional fixation needs to be augmented with external support, which can be given by spanning external fixators across a joint. MATERIALS AND METHODS Our study consists of 38 open fractures of the lower limbs, which are of Gustilo-Anderson’s type IIIB, an MT4 of AO-ASIF soft tissue injury classification essentially requiring open wound management as well as fracture fixation. Wound lavage and debridements are carried out till the soft tissues show granulations. The position in which joint is immobilised is functional and with access to open wound for dressings and inspection without any displacement of the fracture as well as creeping granulation tissue. RESULTS All the cases in our study are maintained with functional position till soft tissue cover is achieved and provisional fixation is done with definitive fixation after soft tissue cover with skin grafting. CONCLUSION Spanning external fixators are useful in maintaining functional positions as well as augmenting the provisional fixation of the compound fractures.

  20. Increasing incidence of hip fracture in Chiang Mai, Thailand.

    Science.gov (United States)

    Wongtriratanachai, Prasit; Luevitoonvechkij, Sirichai; Songpatanasilp, Thawee; Sribunditkul, Siripoj; Leerapun, Taninnit; Phadungkiat, Sompant; Rojanasthien, Sattaya

    2013-01-01

    Hip fracture is a major health problem in Thailand. This study attempted to examine the incidence, related factors, and trends of hip fracture in Chiang Mai, Thailand. All hip fracture data among patients aged 50 yr or older were collected from hospitals in Chiang Mai, Thailand from August 1, 2006 to July 3, 2007. Data from the 1997 Chiang Mai hip fracture study were used for comparison. In the study period, 690 hip fractures were reported: 203 males and 487 females (male to female ratio was 1 to 2.4), with a mean age of 76.7 yr. The estimated cumulative incidence was 181.0 per 100,000, and the adjusted incidence was 253.3 (males: 135.9; females: 367.9). A simple fall was the most common mechanism (79%) of fracture, and 80% of the hip fractures occurred in patients aged 70 yr or older. The highest incidence of hip fracture was observed in patients older than 85 yr (1239). At 6 mo postfracture, most patients (61%) used a walking aid. Compared with the 1997 data, hip fracture incidence had increased by an average of 2% per yr, and the incidence of hip fracture had increased significantly from August 1, 2006 to July 31, 2007, especially in patients older than 75 yr. In patients older than 84 yr, the incidence increased by a factor of 2. Urgent strategies for the prevention and treatment of osteoporosis, and hence hip fracture, are needed.

  1. External fixation combined with limited internal fixation in the treatment of pilon tibia fractures

    Directory of Open Access Journals (Sweden)

    Golubović Zoran

    2007-01-01

    Full Text Available Background/Aim. Intraarticular fractures of the tibial plafond (pilon fractures belong to the group of most severe fractures. They are usually caused by high-energy trauma and frequently associated with a marked soft-tissue damage. Surgical treatment has replaced the traditional nonoperative treatment. The aim of this study was to present the results of the treatment of distal tibial intraarticular fracture by the use of internal fixation, as well as the combination of minimal internal fixation and external fixation. Methods. The study included 47 patients with pilon tibia fractures who went through at the Clinic for Orthopedics and Traumatology, School of Medicine, Niš (1995-2004. Within the analyzed group there were 33 (70.2% males and 14 (29.8% females. The patients mean age was 45.8 years. In the first group, which consisted of 22 patients, open reduction and internal fixation of both the tibia and the fibula was performed in the two separate incisions. The second group consisted of 25 patients managed with external fixation by external fixator "Mitković" with limited internal fixation. Besides external fixation, a minimal internal fixation was performed by the use of Kirschner wires and screws. The patients were followed-up inside a 24-months-period. Results. The obtained was a substantially high number of complications after open reduction and internal fixation in the group of patients. There was no difference in a long-term clinical outcome. Postoperative osteitis, as the most severe complication in the management of closed pilon tibia fractures, was not registered in the second group. Conclusion. Considering the results obtained in this study, it can be concluded that external fixation by the "Mitković" external fixator with the minimal internal fixation is a satisfactory method for the treatment of fractures of the tibial plafond causing less complications than internal fixation. .

  2. Adult periarticular locking plates for the treatment of pediatric and adolescent subtrochanteric hip fractures.

    Science.gov (United States)

    Sanders, Samuel; Egol, Kenneth A

    2009-01-01

    Two cases are presented in which adult, precontoured, lower-extremity periarticular locking plates were utilized for fixation of subtrochanteric femur fractures in pediatric patients. Recognition of the fact that a distal tibial locking plate in a small child and a proximal tibial locking plate in an adolescent anatomically ft the proximal femur in each case may provide a surgeon treating subtrochanteric hip fractures in this population increased options for operative stabilization.

  3. Quality of life after hip fracture in the elderly: A systematic literature review.

    Science.gov (United States)

    Peeters, Charles M M; Visser, Eva; Van de Ree, Cornelis L P; Gosens, Taco; Den Oudsten, Brenda L; De Vries, Jolanda

    2016-07-01

    With an increasing ageing population, hip fractures have become a major public health issue in the elderly. It is important to examine the health status (HS) and health-related quality of life (HRQOL) of the elderly faced with the epidemic of hip fractures. To provide an overview of reported HS and HRQOL in elderly patients with a hip fracture. A systematic literature search was performed in Embase, Medline, Web of Science, Scopus, CINAHL, Cochrane, PsycINFO, Pubmed, and Google Scholar in July 2014. Studies which reported the HS or HRQOL based on standardised questionnaires in patients older than 65 years with a hip fracture were considered eligible for inclusion. After inspecting the 2725 potentially eligible studies, 49 fulfilled the inclusion criteria. All included studies were randomised controlled trials or prospective cohort studies. The methodological quality of the studies was moderate. Patients' functioning on the physical, social, and emotional domains were affected after a hip fracture. The HS and HRQOL of the majority of patients recovered in the first 6 months after fracture. However, their HS did not return to prefracture level. Mental state, prefracture functioning on physical and psychosocial domains, comorbidity, female gender, nutritional status, postoperative pain, length of hospital stay, and complications were factors associated with HS or HRQOL. Treatment with total hip arthroplasty or hemi-arthroplasty provided better HS than treatment with internal fixation with displaced femoral neck fractures. Supportive psychotherapy in "low-functioning" patients, (home) rehabilitation programmes and nutritional supplementation appeared to have beneficial effects on HS. Optimizing nutrition intake, (home) rehabilitation programmes, and the possibility for psychological counselling in patients with difficulties in the psychosocial dimensions would be recommended after hip fracture surgery. Besides HS questionnaires like EQ-5D and SF-36, adequate

  4. Displaced Anterior Column Acetabular Fracture: Closed Reduction and Percutaneous CT-Navigated Fixation

    Energy Technology Data Exchange (ETDEWEB)

    Huegli, R.W.; Staedele, H.; Messmer, P.; Regazzoni, P.; Steinbrich, W.; Gross, T. [Univ. Hospital of Basel (Switzerland). Dept. of Radiology

    2004-10-01

    The purpose of this study is to demonstrate the feasibility of computer-tomography-navigated closed reduction and percutaneous fixation (CRPF) in a patient with an externally rotated left acetabular fracture. After a follow-up of 18 months the patient was pain-free and had a normal range of motion in both hip joints. Radiologically, the fracture was fully consolidated, remodelled, and there were no signs of osteoarthritis. To our knowledge, CT-navigated CRPF of a rotated acetabular fracture has not been reported before. Further studies regarding the feasibility of the method are warranted(CRPF)

  5. Schizophrenia, antipsychotics and risk of hip fracture

    DEFF Research Database (Denmark)

    Sørensen, Holger J; Jensen, Signe O W; Nielsen, Jimmi

    2013-01-01

    -morbidity, antipsychotics (IRR=1.19; 95% CI 1.15-1.24), antidepressant (IRR=1.18; 95% CI 1.16-1.20), anticholinergics (IRR=1.29; 95% CI 1.22-1.36), benzodiazepines (IRR=1.06; 95% CI 1.04-1.08) and corticosteroids (IRR=1.44; 95% CI 1.36-1.53) were significant predictors. In 556 persons with schizophrenia and hip fracture...

  6. Ipsilateral fracture dislocations of the hip and knee joints with contralateral open fracture of the leg: a rare case and its management principles

    Institute of Scientific and Technical Information of China (English)

    Ramesh Kumar Sen; Sujit Kumar Tripathy; Vibhu Krishnan; Tarun Goyal; Vanyambadi Jagadeesh

    2011-01-01

    This paper discussed the injury mechanism and management of a patient who had concomitant ipsilateral hip and knee dislocations and contralateral open leg fracture.A 32-year-old man presented with ipsilateral fracturedislocations of the left hip (Pipkin's type Ⅳ) and knee (Moore Ⅱ)joints and contralateral open fracture of the leg bones after a car accident. After emergency resuscitative measures, the hip joint was reduced and Pipkin's fracture was fixed using Ganz approach with lag screws; knee joint was reduced closely and tibial plateau fracture was stabilized with lateral buttress plate and a transarticular spanning fixator. The open fracture on the other leg was debrided and fixed with an external fixator. There was no instability in both joints after fixation when he was examined under anesthesia. The fractures united after 3 months and the patient had no residual instability of hip and knee. There was no clinical or radiological evidence of osteonecrosis in the hip joint after 6 months. At one-year follow-up, he had satisfactory functional outcome with almost normal range of motion at both joints.Ipsilateral hip and knee dislocations are rare injuries and more caution is needed for early diagnosis. A timely appropriate intervention can provide good functional outcome to the patient in this situation.

  7. Hip Fracture. A Nine-Year Study.

    Directory of Open Access Journals (Sweden)

    Horacio Suárez Monzón

    2007-08-01

    Full Text Available Background: Recent studies in Cuba stated that a great number of hip fractures are caused due to accidental falls constituting an important health problem in the third age. Objective: To characterize the behaviour of hip fractures from 1997 to 2005 in Cienfuegos Province. Methods: An observational longitudinal descriptive and prospective study was carried out to all patients treated for hip fracture from 1997 to 2005 in the University Hospital ¨Dr. Gustavo Aldereguía Lima¨ in Cienfuegos city. Variable such as age, sex, and topographical diagnosis, and surgical modality, scale of disability, comorbidity, complications, lethality, and second time of admission were taken into account and collected in the analyzed period of time and in specific clinical records elaborated for this purpose. Results: 13,7 per cent of the orthopaedic complications were registered being significantly lower in regard with previous studies in similar contexts. 62 per cent of the assisted patients could get back their initial scale of disability. Conclusions: The results obtained showed the level of experience reached by the specialists using the new technologies at the surgical act.

  8. Comparison of Primary Hip Spica with Crossed Retrograde Intramedullary Rush Pins for the Management of Diaphyseal Femur Fractures in Children: A Prospective, Randomized Study

    Directory of Open Access Journals (Sweden)

    Mohammad Ruhullah

    2013-12-01

    Conclusions: Intra-medullary crossed Rush pinning is an effective method of paediatric diaphyseal femur fracture fixation as compared to primary hip spica in terms of early weight bearing and restoration of normal anatomy.

  9. Hip Hemiarthroplasty for Femoral Neck Fractures Using the Modified ...

    African Journals Online (AJOL)

    The patients had good hip abduction postoperatively. In addition ... Key words: Femoral neck fractures, hip hemiarthroplasty, ... the overall blood loss at surgery and morbidity after surgery, ... Their clinical and demographic features were noted.

  10. Posterior dislocation of hip with ipsilateral intertrochanteric fracture: A report of two cases

    Directory of Open Access Journals (Sweden)

    Rehan Ul Haq

    2016-01-01

    Full Text Available Posterior dislocations of the hip are known to be associated with fractures of the femoral head, neck, shaft, or posterior acetabular wall. However, its association with ipsilateral intertrochanteric fracture has only been anecdotally described in the English literature. We report two such cases managed by open reduction (OR of the hip and internal fixation (IF of the intertrochanteric fracture. The first case was a 26-year-old male who was managed by OR of the hip with IF of the intertrochanteric fracture with a dynamic hip screw and had a good functional result at 1-year followup. The second case was a 36-year-old female who was also managed by OR of the hip with IF of the head fragments with Herbert screw and IF of the intertrochanteric fracture with a dynamic condylar screw. The patient had a fair, functional result at 1-year followup. With the increase in high energy trauma, these fracture patterns have become more common, and there is an urgent need to review the existing classifications so that these fractures are better categorized, and treatment guidelines defined.

  11. Posterior dislocation of hip with ipsilateral intertrochanteric fracture: A report of two cases

    Science.gov (United States)

    Ul Haq, Rehan; Kumar, Jaswant; Dhammi, IK; Jain, Anil K

    2016-01-01

    Posterior dislocations of the hip are known to be associated with fractures of the femoral head, neck, shaft, or posterior acetabular wall. However, its association with ipsilateral intertrochanteric fracture has only been anecdotally described in the English literature. We report two such cases managed by open reduction (OR) of the hip and internal fixation (IF) of the intertrochanteric fracture. The first case was a 26-year-old male who was managed by OR of the hip with IF of the intertrochanteric fracture with a dynamic hip screw and had a good functional result at 1-year followup. The second case was a 36-year-old female who was also managed by OR of the hip with IF of the head fragments with Herbert screw and IF of the intertrochanteric fracture with a dynamic condylar screw. The patient had a fair, functional result at 1-year followup. With the increase in high energy trauma, these fracture patterns have become more common, and there is an urgent need to review the existing classifications so that these fractures are better categorized, and treatment guidelines defined. PMID:27746503

  12. Anterior internal fixation to treat vertical unstable pelvic fracture

    Institute of Scientific and Technical Information of China (English)

    王世松; 张鹏程; 杜敦进; 杨泗华

    2002-01-01

    With the Chinese development of industry, agriculture and communication, various traffic and work related accidents are increasing, leading to an increase in pelvic fractures. Among the different kinds of fractures, pelvic fracture is the third largest cause of death.1 The treatment of pelvic fractures is a “hot spot” and a difficult point in orthopedic surgery. Since 1998 we have treated 20 patients with vertical unstable pelvic fracture using anterior internal fixation. Satisfactory results have been obtained.

  13. Postoperative radiographs following hip fracture surgery. Do they influence patient management?

    Science.gov (United States)

    Chakravarthy, J; Mangat, K; Qureshi, A; Porter, K

    2007-03-01

    There is still much debate on the appropriateness of taking postoperative radiographs following hip fracture surgery. In our unit, it is routine practice to request postoperative radiographs after hip hemiarthroplasty but not after internal fixation. An audit conducted in our unit highlighted the low acute implant-related complications. This prompted us to conduct a national audit on current UK practice regarding the use of check radiographs following hip fracture surgery. Retrospective case note review of all patients undergoing hip fracture surgery at our hospital, from 2002 to 2004, was performed. Patients undergoing revision surgery in the same admission were identified to determine whether check radiograph influenced the decision. Subsequently a postal performa was sent to 450 randomly chosen UK Orthopaedic Consultants. The performa was designed to determine practice relating to postoperative radiographs. It also attempted to determine whether postoperative radiographs (when requested) influenced the subsequent clinical management of the patient. A total of 1265 hip fractures treated surgically were reviewed locally. Average length of stay was 29.5 days. There were five acute implant-related complications. One revision was performed for a long hip screw which was obvious on the intra-operative image intensifier films. Only one decision to revise (because of incongruous reduction of a hip hemiarthroplasty) was based on a problem identified on a routine check radiograph. All patients undergoing revision were clinically symptomatic. We received 300 responses. Ninety-six per cent routinely took postoperative radiographs following hip hemiarthroplasty of which 83% allowed the patient to mobilise before checking the radiograph. Following dynamic hip screw (DHS)/dynamic condylar screw (DCS) fixation, 61% took check radiographs of which 75% allowed the patient to mobilise prior to reviewing the radiograph. Following cannulated screw (CS) fixation, 58% routinely

  14. Biomechanical analysis of four types of internal fixation in subtrochanteric fracture models.

    Science.gov (United States)

    Wang, Jie; Ma, Xin-long; Ma, Jian-xiong; Xing, Dan; Yang, Yang; Zhu, Shao-wen; Ma, Bao-yi; Chen, Yang; Feng, Rui; Jia, Hao-bo; Yu, Jing-tao

    2014-05-01

    To compare the biomechanical properties of four types of internal fixation (proximal femoral nail [PFN], dynamic hip screw [DHS], dynamic condylar screw [DCS], and proximal femoral locking plate [PFLP]) for different types of subtrochanteric fractures. Thirty-two antiseptic femurs were randomly divided into four groups. After internal fixation had been implanted, different types of subtrochanteric fracture models were produced and each tested under vertical, torsional and vertical damage loads. The stiffness ratio of PFN in each fracture model and failure load were the highest in the four groups; however, the torsional stiffness ratio was the lowest. Tension strain ratios of DHS and DCS on the lateral side became compression strain ratios with restoration of the medial fragment. The stiffness ratio of DHS was lower than PFLP in each fracture model, torsional stiffness ratio was the highest in fracture models II to V and the failure load was lower only than PFN. The stiffness ratio and failure load of DCS were both the lowest, torsional stiffness ratio was similar to PFLP's in fracture models II to V. The stiffness ratio of PFLP was only lower than PFN's in each fracture model, but the failure load was lower than DHS's. Four types of internal fixation achieve better stabilities for type I subtrochanteric fractures. PFN and PFLP produce reliable stability in type IIIA subtrochanteric fractures. If the medial buttress is restored, DCS can be considered. For type IV subtrochanteric fractures, only PFN provides stable fixation. PFLP is suitable for comminuted fractures with large fragments. © 2014 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  15. Total Hip Arthroplasty for Implant Rupture after Surgery for Atypical Subtrochanteric Femoral Fracture

    Science.gov (United States)

    Ozaki, Yu; Ochi, Hironori; Watari, Taiji; Matsumoto, Mikio; Kaneko, Kazuo

    2016-01-01

    Treatment methods for delayed union and nonunion of atypical femoral fracture are still controversial. Moreover, no treatment method has been established for implant rupture caused by delayed union and nonunion. We encountered a 74-year-old female in whom nonunion-induced implant rupture occurred after treatment of atypical subtrochanteric femoral fracture with internal fixation using a long femoral nail. It was unlikely that sufficient fixation could be obtained by repeating osteosynthesis alone. Moreover, the patient was elderly and early weight-bearing activity was essential for early recovery of ADL. Based on these reasons, we selected one-stage surgery with total hip arthroplasty and osteosynthesis with inverted condylar locking plate as salvage procedures. Bone union was achieved at 6 months after surgery. This case illustrated that osteosynthesis-combined one-staged total hip arthroplasty could be considered as one of the options for nonunion-induced implant rupture of atypical femoral subtrochanteric fracture. PMID:27818818

  16. Total Hip Arthroplasty for Implant Rupture after Surgery for Atypical Subtrochanteric Femoral Fracture

    Directory of Open Access Journals (Sweden)

    Yu Ozaki

    2016-01-01

    Full Text Available Treatment methods for delayed union and nonunion of atypical femoral fracture are still controversial. Moreover, no treatment method has been established for implant rupture caused by delayed union and nonunion. We encountered a 74-year-old female in whom nonunion-induced implant rupture occurred after treatment of atypical subtrochanteric femoral fracture with internal fixation using a long femoral nail. It was unlikely that sufficient fixation could be obtained by repeating osteosynthesis alone. Moreover, the patient was elderly and early weight-bearing activity was essential for early recovery of ADL. Based on these reasons, we selected one-stage surgery with total hip arthroplasty and osteosynthesis with inverted condylar locking plate as salvage procedures. Bone union was achieved at 6 months after surgery. This case illustrated that osteosynthesis-combined one-staged total hip arthroplasty could be considered as one of the options for nonunion-induced implant rupture of atypical femoral subtrochanteric fracture.

  17. Treatment of stable and unstable intertrochanteric fractures with selfdynamisable internal fixator (concept of double dynamisation

    Directory of Open Access Journals (Sweden)

    Kostić Igor M.

    2015-01-01

    Full Text Available Bacground/Aim. Intertrochanteric fractures of the femur are the third most common fractures among all bone fractures. Today in everyday orthopedic practice a number of different methods of treatment of trochanteric fractures of the femur are applied. Despite the improvement in the development of new implants, the percentage of serious complications of the treatment of these fractures remains very high, varying from 10% to 20%. One of the most serious complications of internal fixation of intertrochanteric fractures is nonunion of fractures due to the lack of additional axial dynamisation of implants. The aim of this study was to determine the efficacy of double dynamisation in stable and unstable intertrochanteric fractures treatment using the self dynamisable internal fixator. Methods. During the period from 2000 to 2009 we analyzed the use of selfdynamisable internal fixator (SIF implant in the treatment of 247 patients with stable and unstable intertrochanteric fractures. Fracture types were classified according to the AO Fracture Classification/Orthopaedic Trauma Association Scheme. Salvati and Wilson scoring systems were used for functional assessment considering pain, walking ability and hip movements of operated patients. Results. Of the total number of treated patients, 134 were males and 113 females, aged 19 to 90 (average 49.6 years. More than a half of the patients were older than 50 years. Monitoring of the patients after the operation was carried out clinically and radiographically for a period of three to six months in all the patients, whereas a 2-year follow-up was conducted in 176 (71.2% patients. The average duration of surgery was 47 min, the average blood loss 145 mL, and the average fluoroscopy time was 16 sec (8-97 sec. The average time for union was 3.7 months (3-6.5 months. Double dynamisation (dynamisation along the neck and shaft of the femur was observed in 85 (34.4% patients, and was on average 4.3 mm (1.5-8 mm. All

  18. Off-hours admission and quality of hip fracture care

    DEFF Research Database (Denmark)

    Kristiansen, Nina Sahlertz; Kristensen, Pia Kjær; Nørgård, Bente Mertz

    2016-01-01

    OBJECTIVE: Higher risks of adverse outcomes have been reported for patients admitted acutely during off-hours. However, in relation to hip fracture, the evidence is inconsistent. We examined whether time of admission influenced compliance with performance measures, surgical delay and 30-day...... mortality in patients with hip fracture. DESIGN: Cohort study. SETTING: Data from The Danish Multidisciplinary Hip Fracture Registry linked with data from Danish National Registries. PARTICIPANTS: Danish patients undergoing hip fracture surgery, aged >65 years, admitted 1 March 2010 to 30 November 2013 (N...

  19. Outcome Analysis of Locking Plate Fixation in Proximal Humerus Fracture

    Science.gov (United States)

    Pathak, Abhishek; Gaur, Sanjiv

    2016-01-01

    Introduction Proximal humerus fractures account for approximately 5% of all fractures. Stable minimally displaced fractures can be treated nonoperatively but the management of displaced fractures remain controversial with various modalities of treatment available. Locking plates provide stable fixation and enable early postoperative mobilization specially in osteoporotic proximal humerus fracture. Aim To evaluate the functional outcome of locking plate fixation and to compare the results of two approaches used for fixation. Materials and Methods This prospective study was conducted at a tertiary level hospital between September 2011 to December 2013. PHILOS plates were used for internal fixation of displaced proximal humerus fractures Neer’s type 2 part, 3 part and 4 part fractures on 26 patients (M/F ratio 1.36:1; mean age 46 years). According to Neer classification, 5,12 and 9 patients had displaced 2, 3 and 4 part fractures respectively. Deltopectoral and deltoid splitting approaches were used for fixation on 13 patients each. Functional outcome was assessed using Constant-Murley shoulder score. Graphpad software version 6.0 was used with Chi-square test and Fisher-exact test are used to compare data. The p-value .05) and all fractures were united. Conclusion Our study demonstrates that locking plate fixation gives good functional outcomes in treatment of proximal humerus fractures. There was no significant difference in the two approaches used for exposure. Our results are comparable to various studies conducted by other authors which states that locking plates provide better functional and radiological outcomes as compared to other fixation methods like Tension band wiring, percutaneous K-wire fixation, non-locking plates, intramedullary nails. PMID:27656515

  20. Does bone mineral density affect hip fracture severity?

    Science.gov (United States)

    Spencer, Simon J; Blyth, Mark J G; Lovell, Frances; Holt, Graeme

    2012-06-01

    The association between hip fracture and reduced bone mineral density is well documented, with reduced bone mineral density predisposing to fracture. However, it is unknown whether an association exists between the magnitude of bone density lost and the severity of the hip fracture sustained. One hundred forty-two patients (96 women, 46 men) with a mean age of 74 years (range, 49-92 years) who sustained a hip fracture following a simple ground-level fall and were treated for this injury were reviewed. All patients had undergone dual-energy x-ray absorptiometry bone scanning of the contralateral hip and lumbar spine. Fractures were classified as intra- or extracapsular or subtrochanteric and then subclassified by degree of severity as simple (stable) or multifragmentary (unstable) fracture patterns.Although a low hip bone mineral density (T- or Z score fracture (P=.025) compared with other fracture types, no association existed between bone mineral density and the severity of the resultant hip fracture. Although an association exists between bone mineral density and the risk of fragility fractures, the results of the current study suggest that the severity of hip fractures does not follow this correlation. Therefore, no assumption can be made about bone mineral density of the proximal femur based on the severity of the fracture observed on plain radiographs. Copyright 2012, SLACK Incorporated.

  1. [Investigate progress of intraoperative periprosthetic fracture of total hip arthroplasty].

    Science.gov (United States)

    Cong, Yu; Zhao, Jian-ning

    2011-02-01

    One of the complications of total hip arthroplasty is intraoperative periprosthetic fracture. Periprosthetic fracture is divided into acetabular fracture and femoral fracture. Risk factors for intraoperative periprosthetic fracture include use of minimally invasive techniques, press-fit cementless stems, revision operations and osteoporosis. It has been recognized that treatment of intraoperative periprosthetic fractures should be based on the classification of the Vancouver system for intraoperative fractures.

  2. Contralateral hip fractures and other osteoporosis-related fractures in hip fracture patients: Incidence and risk factors. An observational cohort study of 1,229 patients

    NARCIS (Netherlands)

    A.J.H. Vochteloo (Anne); B.L. Borger van der Burg (Boudewijn); M.L. Röling (Maarten); D.H.-J. van Leeuwen (Diederik); P. van den Berg (Peter); A.H.P. Niggebrugge (Arthur); M.R. de Vries (Mark); W.E. Tuinebreijer (Wim); R.M. Bloem (Rolf); R.G.H.H. Nelissen (Rob); P. Pilot (Peter)

    2012-01-01

    textabstractPurpose: To report risk factors, 1-year and overall risk for a contralateral hip and other osteoporosis-related fractures in a hip fracture population. Methods: An observational study on 1,229 consecutive patients of 50 years and older, who sustained a hip fracture between January 2005

  3. 人工股骨头置换与动力髋螺钉内固定治疗股骨粗隆间骨折的效果比较%Comparison of hip arthroplasty and internal fixation for the treatment of intertrochanteric fractures

    Institute of Scientific and Technical Information of China (English)

    熊秉刚; 谢文伟; 姚汉刚; 利盛成; 廖德允; 李再学; 黎明华; 苏厂尧

    2008-01-01

    Objective To compare the effect of hip artificial replacement and DHS internal fixation for the treatment of intertrochanteric fracture, and investigate the difference of the two method. Methods Eighty-six pa- tients with intertrochanterie fracture patients were treated with hip arthroplasty, and dynamic hip screw. The pa- tients were followed up for 6 months, and compared the operation rime, blood loss, postoperative complications, sur- vival rate, postoperative hip function score and lose situation. Results There was no significant difference in opera- tion time,blood loss,postoperative complications,in local symptoms hip varus deformation occured in the DHS inter- hal fixation because lag screw cut-our and the collapse of the medial cortex, hip and thigh pain oecured in artificial re- placement,hip function score dropped 9.5 % in DHS and 9.2% in artificial replacement. Conclusion For elderly patients, eomminuted fracture and osteoporosis, and other types of unstable intertrochanteric fracture patients, the primary purpose of surgery is to provide to patients more activities of the early conditions,so hip arthroplasty can be used to the treatment of intertrochanteric fracture,as a reasonable replacement surgery.%目的 通过对使用人工股骨头置换与动力髋螺钉(DHs)内固定治疗股骨粗隆间骨折的结果进行比较分析,探讨两者之间的差别.方法 86例高龄股骨粗隆间骨折患者,分别采用人工股骨头置换(半髋组)及DHS内固定方法(DHS组)治疗,经过6个月以上的随访,比较两组患者在手术时间、术中出血、术后并发症、累积生存情况、术后髋部功能评分及丢失情况等方面存在的差异.结果 两组患者在手术时间、术中出血、术后全身并发症等方面无明显差异.局部症状,DHS组出现了内固定穿出骨皮质以及内侧皮质塌陷所造成的髋内翻现象,而半髋组患者则出现髋部及大腿疼痛;DHS组髋关节综合评分下降9.5%,

  4. The association between hip fracture and hip osteoarthritis: A case-control study

    Directory of Open Access Journals (Sweden)

    Englund Martin

    2010-11-01

    Full Text Available Abstract Background There have been reports both supporting and refuting an inverse relationship between hip fracture and hip osteoarthritis (OA. We explore this relationship using a case-control study design. Methods Exclusion criteria were previous hip fracture (same side or contralateral side, age younger than 60 years, foreign nationality, pathological fracture, rheumatoid arthritis and cases were radiographic examinations were not found in the archives. We studied all subjects with hip fracture that remained after the exclusion process that were treated at Akureyri University Hospital, Iceland 1990-2008, n = 562 (74% women. Hip fracture cases were compared with a cohort of subjects with colon radiographs, n = 803 (54% women to determine expected population prevalence of hip OA. Presence of radiographic hip OA was defined as a minimum joint space of 2.5 mm or less on an anteroposterior radiograph, or Kellgren and Lawrence grade 2 or higher. Possible causes of secondary osteoporosis were identified by review of medical records. Results The age-adjusted odds ratio (OR for subjects with hip fracture having radiographic hip OA was 0.30 (95% confidence interval [95% CI] 0.12-0.74 for men and 0.33 (95% CI 0.19-0.58 for women, compared to controls. The probability for subjects with hip fracture and hip OA having a secondary cause of osteoporosis was three times higher than for subjects with hip fracture without hip OA. Conclusion The results of our study support an inverse relationship between hip fractures and hip OA.

  5. Open reduction and internal fixation of proximal humerus fractures.

    Science.gov (United States)

    Drosdowech, Darren S; Faber, Kenneth J; Athwal, George S

    2008-10-01

    Open reduction of proximal humeral fractures has the advantage of providing direct control over each fracture fragment and permitting anatomic reduction and fixation with advanced devices. Modern fixed-angle locking plates designed specifically for proximal humerus fractures have allowed the expansion of surgical indications permitting surgeons to address more complicated fractures. Advanced preoperative imaging and fluoroscopy allow a better understanding of fracture patterns and permit the surgeon to use this knowledge intraoperatively. Research is required to further validate fracture classification systems, to develop surgical guidelines for decision making, and to compare the outcomes of the various treatments options for proximal humerus fractures.

  6. Total hip replacements done without cement after acetabular fractures: a 4- to 8-year follow-up study.

    Science.gov (United States)

    Huo, M H; Solberg, B D; Zatorski, L E; Keggi, K J

    1999-10-01

    Twenty-one patients (21 hips) underwent cementless total hip replacement surgeries for previous acetabular fractures. The mean age at the time of hip replacement was 52 years (range, 23-78 years). The mean follow-up was 65 months (range, 48-104 months). One hip required revision of the stem secondary to a periprosthetic femur fracture from a fall at 3 months after surgery. Good to excellent clinical rating was achieved and maintained in 19 hips. Radiographic evaluation demonstrated stable cup and stem fixation in 17 and 15 hips. Only 1 patient with radiographic loosening of the components was sufficiently symptomatic. The results in this series appeared slightly better than those reported previously in hip replacements done with cement at comparable medium-term follow-up. The mechanical failure rates remained high in this patient population: 19% for the cups and 29% for the stems.

  7. Operative Fixation of Rib Fractures Indications, Techniques, and Outcomes.

    Science.gov (United States)

    Galos, David; Taylor, Benjamin; McLaurin, Toni

    2017-01-01

    Rib fractures are extremely common injuries and vary in there severity from single nondisplaced fractures to multiple segmental fractures resulting in flail chest and respiratory compromise. Historically, rib fractures have been treated conservatively with pain control and respiratory therapy. However this method may not be the best treatment modality in all situations. Operative fixation of select rib fractures has been increasing in popularity especially in patients with flail chest and respiratory compromise. Newer techniques use muscle sparing approaches and precontoured locking plate technology to obtain stable fixation and allow improved respiration. Current reports shows that rib fracture fixation offers the benefits of improved respiratory mechanics and improved pain control in the severe chest wall injury with resultant improvement in patient outcomes by decreasing time on the ventilator, time in the intensive care unit, and overall hospital length of stay.

  8. Orthogeriatric Service Reduces Mortality in Patients With Hip Fracture

    DEFF Research Database (Denmark)

    Stenqvist, Charlotte; Madsen, Christian Medom; Riis, Troels

    2016-01-01

    INTRODUCTION: Orthogeriatric service has been shown to improve outcomes in patients with hip fracture. The purpose of this study is to evaluate the effect of orthogeriatrics at Bispebjerg University Hospital, Denmark. The primary outcome is mortality inhospital and after 1, 3, and 12 months for p......, and ASA score. Future trials should include frail patients with other fracture types who can benefit from orthogeriatrics.......INTRODUCTION: Orthogeriatric service has been shown to improve outcomes in patients with hip fracture. The purpose of this study is to evaluate the effect of orthogeriatrics at Bispebjerg University Hospital, Denmark. The primary outcome is mortality inhospital and after 1, 3, and 12 months...... for patients with hip fracture. The secondary outcome is mortality for home dwellers and nursing home inhabitants. MATERIALS AND METHODS: This is a retrospective clinical cohort study with an historic control group including all patients with hip fracture admitted from 2007 to 2011. Patients with hip fracture...

  9. Prevalence of dementia in elderly patients with hip fracture.

    Science.gov (United States)

    Yiannopoulou, Konstantina G; Anastasiou, Ioannis P; Ganetsos, Theodore K; Efthimiopoulos, Petros; Papageorgiou, Sokratis G

    2012-01-01

    Hip fractures occur commonly and are a cause of disability for older adults and lead to increased dependence and requirements for social support. Dementia is one of the possible risk factors for falling and hip fracture, a potential source for complications during surgery and during the postoperative period, difficulties in rehabilitation and a risk factor for hip fracture reccurence. However, in previous studies of hip fracture patients, cognitive status has not been formally assessed during the inpatient stay and diagnosis was based only on previous history. Additionally, no previous studies have compared prevalence of dementia between elderly patients with hip fracture and patients with other surgical pathology. Our aim was to define whether dementia was more prevalent in older subjects with hip fracture than in other elderly patients undergoing surgery. In this study, we prospectively assessed all patients aged 68 and older admitted to our hospital for hip fracture surgery during a one year period and compared them with age and gender matched patients attending other surgical departments. 80 hip fracture patients and 80 controls were assessed for dementia. Dementia was common in both groups, presumably reflecting the advanced mean age of both groups and cognitive deterioration due to hospitalization-status. Dementia was significantly higher in the hip fracture group (85%) compared to the control group (61.5%; p=0.002). Dementia is very common in older patients admitted for surgery to a general hospital and extremely common in those with hip fracture. It seems that dementia is under diagnosed in elderly hospitalised patients. Our data confirm that dementia is a major risk factor for hip fracture in the elderly.

  10. Efficacy of three methods of internal fixation on femoralneck fracture

    Institute of Scientific and Technical Information of China (English)

    闫洪印; 陈扬; 肖建德; 李振宇; 龚敏; 马若凡; 刘尚礼

    2002-01-01

    @@ From 1990 to 2000, we used Hansson pin, AOhollow-pulling screw, and bendable screw to treat150 cases of fresh femoral neck fracture and theresult was analysed to compare the efficacy of the threemethods of internal fixation.

  11. Percutaneous K-wire fixation in paediatric Supracondylar fractures ...

    African Journals Online (AJOL)

    Percutaneous K-wire fixation in paediatric Supracondylar fractures of humerus: A retrospective study. ... Nigerian Medical Journal ... conducted in the Department of Orthopaedic surgery in M. M. Medical College from July 2005 to July 2010.

  12. Bone Marrow Stem Cells Added to a Hydroxyapatite Scaffold Result in Better Outcomes after Surgical Treatment of Intertrochanteric Hip Fractures

    Directory of Open Access Journals (Sweden)

    Joao Torres

    2014-01-01

    Full Text Available Introduction. Intertrochanteric hip fractures occur in the proximal femur. They are very common in the elderly and are responsible for high rates of morbidity and mortality. The authors hypothesized that adding an autologous bone marrow stem cells concentrate (ABMC to a hydroxyapatite scaffold and placing it in the fracture site would improve the outcome after surgical fixation of intertrochanteric hip fractures. Material and Methods. 30 patients were randomly selected and divided into 2 groups of 15 patients, to receive either the scaffold enriched with the ABMC (Group A during the surgical procedure, or fracture fixation alone (Group B. Results. There was a statistically significant difference in favor of group A at days 30, 60, and 90 for Harris Hip Scores (HHS, at days 30 and 60 for VAS pain scales, for bedridden period and time taken to start partial and total weight bearing (P<0.05. Discussion. These results show a significant benefit of adding a bone marrow enriched scaffold to surgical fixation in intertrochanteric hip fractures, which can significantly reduce the associated morbidity and mortality rates. Conclusion. Bone marrow stem cells added to a hydroxyapatite scaffold result in better outcomes after surgical treatment of intertrochanteric hip fractures.

  13. Treatment of ipsilateral hip and femoral shaft fractures with reconstructive intramedullary interlocking nail

    Institute of Scientific and Technical Information of China (English)

    吴立东; 吴琼华; 严世贵; 潘志军

    2004-01-01

    Objective: To evaluate the results of reconstructive intramedullary interlocking nail in the treatment of ipsilateral hip and femoral shaft fractures. Methods: From August 1997 to November 2001, 13 patients were treated with the reconstructive intramedullary interlocking nail. Nine patients were associated with ipsilateral femoral neck fractures, three with ipsilateral intertrochanteric fractures, and one with subtrochanteric fracture. Results: The follow-up time was from 6 to 38 months with an average of 14 months. All the femoral shaft and hip fractures healed up well. There was no nonunion of the femoral neck, and only one varus malunion. No patient had avascular necrosis of the femoral head. The average healing time for femoral neck fracture was 4.6 months and for shaft fracture 5.8 months. The joint movement and other functions were fairly resumed. Conclusions: The reconstructive intramedullary interlocking nail, with less trauma, reliable fixation, and high rate of fracture healing, is an ideal method of choice in the treatment of ipsilateral hip and femoral shaft fractures.

  14. Low-trauma fractures indicate increased risk of hip fracture in frail older people.

    Science.gov (United States)

    Chen, Jian Sheng; Cameron, Ian D; Simpson, Judy M; Seibel, Markus J; March, Lyn M; Cumming, Robert G; Lord, Stephen R; Sambrook, Philip N

    2011-02-01

    This study aims to investigate the risk of subsequent fractures after low-trauma fracture in frail older people. A total of 1412 elderly residents (mean age 86.2 years, SD 7.0 years, female 77%) were recruited from aged care facilities in Australia. Residents were assessed and then followed for any fracture for 2 years and hip fractures for at least 5 years. Residents with and without a newly acquired fracture in the first 2 years were compared for risk of subsequent hip fracture. Residents with a nonhip fracture in the first 2 years had an increased risk of subsequent hip fracture for about 2.5 years, whereas those with a hip fracture had a similar risk over the whole period compared with those with no fracture. During these 2.5 years, 60, 28, and 6 subsequent hip fractures occurred in the nonfracture group (n = 953), the nonhip fracture group (n = 194), and the hip fracture group (n = 101), respectively, resulting in the probability of subsequent hip fracture of 8.0%, 19.9%, and 10.4%, respectively. Compared with the nonfracture group, the hazard ratio (HR) was 2.82 [95% confidence interval (CI) 1.73-4.59; p < .001] for the nonhip fracture group and 1.48 (95% CI 0.63-3.49, p = .37) for the hip fracture group after adjusting for age, sex, residence type, calcaneal broadband ultrasound attenuation, fracture history, weight, lower leg length, immobility, cognitive function, and medications. Frail institutionalized older people with newly acquired fractures are at increased risk of subsequent hip fracture for the next few years. Accordingly, despite their advanced age, they are a high-priority target group to investigate interventions that might reduce the risk of hip fracture.

  15. The quality of life after a femoral neck fracture in elderly patients: a comparative study between internal fixation and arthroplasties

    Directory of Open Access Journals (Sweden)

    Dennis Sansanovicz

    2017-01-01

    Full Text Available Introduction: The femoral neck fracture is a frequent pathology in the elderly population, with about of 100,000 cases per year in Brazil. The surgical treatment by internal fixation or arthroplastic hip replacement is advocated today. The non-surgical treatment is reserved for cases of exception. Objective: To compare the quality of patient postoperative life treated for femoral neck fracture by two different techniques: hip arthroplasty and internal fixation. Methods: Through the SF-36 questionnaire, we study the quality of life of 60 patients with more than 65 years, treated between 2004 and 2012 in our service. Half of the patients was submitted to internal fixation and the other half to the arthroplastic replacement. Results: Higher averages in the large majority of the parameters of the questionnaire were obtained by the group which was carried out by internal fixation, but without statistical significance in most of these differences. Some international reports indicate that patients who have suffered a fracture of the femoral neck and were treated with internal fixation may recover the quality of life they had before the fracture. Paradoxically, there is a growing trend among orthopedic surgeons to perform a hip replacement surgery in these cases. Conclusion: Further studies are needed to define which is the best surgical treatment option.

  16. Minimal Invasive Percutaneous Fixation of Thoracic and Lumbar Spine Fractures

    Directory of Open Access Journals (Sweden)

    Federico De Iure

    2012-01-01

    Full Text Available We studied 122 patients with 163 fractures of the thoracic and lumbar spine undergoing the surgical treatment by percutaneous transpedicular fixation and stabilization with minimally invasive technique. Patient followup ranged from 6 to 72 months (mean 38 months, and the patients were assessed by clinical and radiographic evaluation. The results show that percutaneous transpedicular fixation and stabilization with minimally invasive technique is an adequate and satisfactory procedure to be used in specific type of the thoracolumbar and lumbar spine fractures.

  17. Acute cognitive dysfunction after hip fracture

    DEFF Research Database (Denmark)

    Bitsch, M S; Foss, N B; Kristensen, B B;

    2006-01-01

    BACKGROUND: Patients undergoing hip fracture surgery often experience acute post-operative cognitive dysfunction (APOCD). The pathogenesis of APOCD is probably multifactorial, and no single intervention has been successful in its prevention. No studies have investigated the incidence of APOCD after......, fourth and seventh post-operative days with the Mini Mental State Examination (MMSE) score. RESULTS: Thirty-two per cent of patients developed a significant post-operative cognitive decline, which was associated with several pre-fracture patient characteristics, including age and cognitive function......, but also the number of peri-operative transfusions. The development of APOCD was also associated with impaired post-operative rehabilitation and an increased length of stay. APOCD was associated with the development of a major medical complication in 35% of all patients. In 65% of patients developing APOCD...

  18. Preliminary experience with biodegradable implants for fracture fixation

    Directory of Open Access Journals (Sweden)

    Dhillon Mandeep

    2008-01-01

    Full Text Available Background: Biodegradable implants were designed to overcome the disadvantages of metal-based internal fixation devices. Although they have been in use for four decades internationally, many surgeons in India continue to be skeptical about the mechanical strength of biodegradable implants, hence this study. Materials and Methods: A prospective study was done to assess the feasibility and surgeon confidence level with biodegradable implants over a 12-month period in an Indian hospital. Fifteen fractures (intra-articular, metaphyseal or small bone fractures were fixed with biodegradable implants. The surgeries were randomly scheduled so that different surgeons with different levels of experience could use the implants for fixation. Results: Three fractures (one humeral condyle, two capitulum, were supplemented by additional K-wires fixation. Trans-articular fixator was applied in two distal radius and two pilon fractures where bio-pins alone were used. All fractures united, but in two cases the fracture displaced partially during the healing phase; one fibula due to early walking, and one radius was deemed unstable even after bio-pin and external fixator. Conclusions: Biodegradable -implants are excellent for carefully selected cases of intra-articular fractures and some small bone fractures. However, limitations for use in long bone fractures persist and no great advantage is gained if a "hybrid" composite is employed. The mechanical properties of biopins and screws in isolation are perceived to be inferior to those of conventional metal implants, leading to low confidence levels regarding the stability of reduced fractures; these implants should be used predominantly in fracture patterns in which internal fixation is subjected to minimal stress.

  19. Stability of unicortical locked fixation versus bicortical non-locked fixation for forearm fractures

    Institute of Scientific and Technical Information of China (English)

    Timothy J.Pater; Steve I Grindel; Gregory J.Schmeling; Mei Wang

    2014-01-01

    Locking plate fixation is being widely applied for fixation of forearm fractures and has many potential advantages, such as fixed angle fixation and improved construct stability, especially in osteoporotic bone. Biomechanical data comparing locking devices to commonly used Low Contact Dynamic Compression (LCDCP) plates for the fixation of forearm fractures has been lacking. The purpose of this study was to compare the fixation stability of a 3.5-mm unicortical locked plate with bicortical non-locked LCDCP plates. Six matched pairs of fresh frozen cadaveric forearms were randomly assigned to unicortical locked and bicortical unlocked groups. Non-destructive four-point bending and torsional test was performed on the ulna and radius separately, using a servohydraulic testing system to obtain construct stiffness of the intact specimens and specimens after osteotomy and plating. The specimens were then loaded to failure to test the fixation strength. The locked unicortical fixation showed significantly higher bending stiffness than the unlocked bicortical fixation, but with significantly lower stiffness and strength in torsion. Fixation strength was comparable between the two groups under bending, but significantly greater in the bicortical non-locked group under torsion. Findings from this study suggest that postoperative rehabilitation protocols may need modification to limit torsional loading in the early stage when using locked unicortical fixation. The study also points out the potential advantage of a hybrid fixation that combines locked unicortical and unlocked bicortical screws.

  20. Hidden blood loss after surgery for hip fracture

    DEFF Research Database (Denmark)

    Foss, Nicolai Bang; Kehlet, H

    2006-01-01

    Our aim was to determine the total blood loss associated with surgery for fracture of the hip and to identify risk factors for increased blood loss. We prospectively studied 546 patients with hip fracture. The total blood loss was calculated on the basis of the haemoglobin difference, the number ...

  1. Thiazide diuretics and the risk for hip fracture

    NARCIS (Netherlands)

    M. van de Klift (Marjolein); C.E.D. de Laet (Chris); R.M.C. Herings (Ron); Th. Stijnen (Theo); H.A.P. Pols (Huib); B.H.Ch. Stricker (Bruno); M.W.C.J. Schoofs (Marlette); A. Hofman (Albert)

    2003-01-01

    textabstractBACKGROUND: Since most hip fractures are related to osteoporosis, treating accelerated bone loss can be an important strategy to prevent hip fractures. Thiazides have been associated with reduced age-related bone loss by decreasing urinary calcium excretion. OBJECTIVE: To examine the ass

  2. Decreasing incidence of hip fracture in the Funen County, Denmark

    DEFF Research Database (Denmark)

    Nymark, Tine; Lauritsen, Jens; Ovesen, Ole

    2006-01-01

    Hip fracture incidence rates are high, and increase with increasing age. Previous studies have predicted a continued increase in both crude and age-standardized rates.......Hip fracture incidence rates are high, and increase with increasing age. Previous studies have predicted a continued increase in both crude and age-standardized rates....

  3. Feasibility of progressive strength training shortly after hip fracture surgery

    DEFF Research Database (Denmark)

    Overgaard, Jan; Kristensen, Morten T

    2013-01-01

    To investigate the feasibility of a 6-wk progressive strength-training programme commenced shortly after hip fracture surgery in community-dwelling patients.......To investigate the feasibility of a 6-wk progressive strength-training programme commenced shortly after hip fracture surgery in community-dwelling patients....

  4. Fear of falling in older patients after hip fracture

    NARCIS (Netherlands)

    Visschedijk, Johannes Hermanus Maria (Jan)

    2016-01-01

    FoF is possibly one of the most important factors in patients after hip fracture, with a substantial impact on the final results of the rehabilitation process. Moreover, patients with hip fracture who rehabilitate in a SNF with high rates of comorbidity and complications, may have even worse

  5. External validation of the discharge of hip fracture patients score

    NARCIS (Netherlands)

    Vochteloo, Anne J. H.; Flikweert, Elvira R.; Tuinebreijer, Wim E.; Maier, Andrea B.; Bloem, Rolf M.; Pilot, Peter; Nelissen, Rob G. H. H.

    This paper reports the external validation of a recently developed instrument, the Discharge of Hip fracture Patients score (DHP) that predicts discharge location on admission in patients living in their own home prior to hip fracture surgery. The DHP (maximum score 100 points) was applied to 125

  6. Can experts in acetabular fracture care determine hip stability after posterior wall fractures using plain radiographs and computed tomography?

    Science.gov (United States)

    Davis, Adrian T; Moed, Berton R

    2013-10-01

    % (16/28) and 47% (15/32), respectively. Orthopedic traumatologists expert in acetabular fracture care cannot adequately determine hip stability status for fractures involving 20%-50% of the posterior wall using plain radiographs, computed tomography, and the patient's hip dislocation status. If the diagnosis is in doubt, open reduction and internal fixation clearly is the much safer course than nonoperative treatment. Examination under anesthesia should be considered as a helpful addition to the surgeon's armamentarium in determining hip stability status for these fractures.

  7. [Treatment of anemia in hip fracture surgery].

    Science.gov (United States)

    García Pascual, E

    2015-06-01

    Repairing hip fractures is one of the most common surgical procedures and has greater morbidity and mortality. This procedure is also a process that involves a greater need for blood products. Numerous factors influence morbidity, mortality and the use of blood products: patient age, concomitant diseases and drug treatments that change hemostasis and hemorrhaging (preoperative, intraoperative and postoperative), which are usually significant. On top of all this is the presence in a high percentage of cases of preoperative anemia, which can have one or more causes. It is therefore essential to establish an appropriate management of perioperative anemia and optimize the transfusion policy. The aim of this review is to briefly analyze the epidemiology of hip fractures as well as establish a basis for treating perioperative anemia and transfusion policies, proposing guidelines and recommendations for clinical management based on the most current studies. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Effects of depression and antidepressant medications on hip fracture

    Science.gov (United States)

    Cheng, Bi-Hua; Chen, Pau-Chung; Yang, Yao-Hsu; Lee, Chuan-Pin; Huang, Ko-En; Chen, Vincent C.

    2016-01-01

    Abstract This study was conducted to investigate the effects of depression and antidepressant medications on hip fracture. The database of the Taiwan National Health Insurance with medical records of more than 1,000,000 individuals was searched for patients who had hip fracture with or without depression from 1998 to 2009. Patients with the following conditions were excluded: hip fracture due to cancer or traffic accidents, hip fracture that occurred before the diagnosis of depression, and use of antidepressants before the diagnosis of depression. A matched cohort of 139,110 patients was investigated, including 27,822 (17,309 females; 10,513 males) with depression and 111,288 (69,236 females; 42,052 males) without depression (1:4 randomly matched with age, sex, and index date). Among these patients, 232 (158 females and 74 males) had both hip fracture and depression, and 690 (473 females and 217 males) had hip fracture only. The Cox proportional-hazards regression method was used to determine the effect of depression on hip fracture. The hazard ratio (HR) for each clinical parameter was calculated after adjusting for confounders including sex, age, Charlson comorbidity index, urbanization, osteoporosis, and antidepressants. Results showed that patients with major depressive disorder had a 61% higher incidence of hip fracture than those without depression (HR 1.61, 95% confidence interval [CI] 1.19–2.18, P = 0.002). The risk of hip fracture for patients with less severe depressive disorder (dysthymia or depressive disorder, not otherwise specified) was not statistically higher than that of patients with no depression (HR 1.10, 95% CI = 0.91–1.34, P = 0.327). Among the patients with depression, females had a 49% higher incidence for hip fracture than males (HR 1.49, 95% CI 1.30–1.72, P < 0.001). The incidence of hip fracture also increased with age and Charlson comorbidity index scores. Analyses of both all (139,110) patients and only patients (27,822) with

  9. Proximal femoral bone geometry in osteoporotic hip fractures in Thailand.

    Science.gov (United States)

    2015-01-01

    A number of different bone geometries have been reported to be correlated with osteoporosis, bone mineral density and fractures. Those correlations are used for diagnosis, treatment and prediction of fracture risk in osteoporosis cases. However there have been no studies of significant bone parameters predicting osteoporosis and hip fracture in Thailand To evaluate the correlation between geometric parameters of the proximal femur and both the Singh index and bone mineral density as well as to investigate the relationship between those two metrics and osteoporotic hip fracture in the Thai population. Forty-four Thai patients with osteoporotic hip fractures andforty-five healthy Thai people matched for age and gender were included in the present study. Bone mineral density and bone geometry from plain hip radiographs of non-fracture sites in the fracture group and proximal femur radiographs of the same site in the healthy group were measured That data were analyzed to determine levels of correlation. Bone geometries were also analyzed to determine hip fracture predictive capacity. Correlation between the Singh index and bone mineral density was significant (p hip fracture (p = 0.014 and p = 0.035, respectively). Each 1 mm reduction in the width of the femoral medial neck cortex increased the osteoporotic hip fracture risk by a factor of 2.7 (OR = 0.37, 95% CI = 0.15-0.93). In the Thai population, bone geometry from plain radiographs can help predict the risk of osteoporotic hip fracture. Osteoporosis is correlated with a low Singh index value. The width of the femoral medial neck cortex is a reliable predictor of hip fracture risk.

  10. Experiences of well-being and suffering after hip fracture

    DEFF Research Database (Denmark)

    Rasmussen, Birgit; Uhrenfeldt, Lisbeth

    Background: Dependency and limited functional ability is common when older people fracture their hip. Experiences of well-being seem to be important during recovery and when living with a hip fracture as a balancing of suffering. Evidence exists that self-confidence is important during...... rehabilitation and when managing in everyday life after hip fracture. Identifying the meaning of a hip fracture in older people can provide a deeper understanding of what matters during rehabilitation and when managing in everyday life. Aim: To aggregate, appraise, interpret and synthesize findings from...... qualitative studies of lived experiences of well-being and suffering within one year after discharge with hip fracture. Method: Following the methodology of the Joanna Briggs Institute, a three-step literature search strategy was developed. Initially, a structured search was performed in the databases CINAHL...

  11. Internal fixation treatments for intertrochanteric fracture: a systematic review and meta-analysis of randomized evidence.

    Science.gov (United States)

    Yu, Jiajie; Zhang, Chao; Li, Ling; Kwong, Joey S W; Xue, Li; Zeng, Xiantao; Tang, Li; Li, Youping; Sun, Xin

    2015-12-11

    The relative effects of internal fixation strategies for intertrochanteric fracture after operation remain uncertain. We conducted a systematic review and meta-analysis of randomized controlled trials (RCTs) to address this important issue. We searched PubMed, EMBASE and CENTRAL for RCTs that compared different internal fixation implants in patients with intertrochanteric fracture at 6-month follow-up or longer. We ultimately included 43 trials enrolling 6911 patients; most trials were small in sample sizes and events. Their risk of bias was generally unclear due to insufficient reporting. Because of these, no statistically significant differences were present from most of the comparisons across all the outcomes, and no definitive conclusions can be made. However, a number of trials compared two commonly used internal fixation strategies, gamma nail (GN) and sliding hip screw (SHS). There is good evidence suggesting that, compared to SHS, GN may increase the risk of cut out (OR = 1.87, 95% CI, 1.08 to 3.21), re-operation (OR = 1.61, 95% CI, 1.02 to 2.53), intra-operative (OR = 3.14, 95% CI, 1.34 to 7.35) and later fractures (OR = 3.67, 95% CI, 1.37 to 9.83). Future randomized trials or observational studies that are carefully designed and conducted are warranted to establish the effects of alternative internal fixation strategies for intertrochanteric fracture.

  12. Open segmental fractures of the tibia treated by external fixation

    Directory of Open Access Journals (Sweden)

    Golubović Ivan

    2012-01-01

    Full Text Available Introduction. Open segmental fractures of the tibia are rare but severe injuries. In these fractures the wide zone of injury (damage of all structures of the lower leg creates very unsuitable biological conditions for healing of the fracture. Objective. The aim of our work was to present the results of treatment of patients with segmental open fractures of the tibia treated by external fixation. Methods. We analyzed treatment results of 21 patients with open segmental tibial fractures who were treated using the method of external fixation at the Clinical Center Niš from January 1, 1995 to July 31, 2010. The average age of the patients was 53 years; the youngest patient was 27 years and the oldest one 80 years. According to the Gustilo open fracture classification, there were 3 (14.3% type I, 6 (28.6% type II, 8 (38.1% type IIIA, and 4 (19.0% type IIIB. All the patients were treated by a unilateral type Mitković external fixator by Traffix Company. Results. Union was attained in 16 (76.2% fractures without severe complications (pseudoarthrosis, chronic osteitis and angular deformities of over 10 degrees. Among severe complications associated with open segmental tibial fractures, in two cases we registered septic pseudoarthrosis, in one aseptic pseudoarthrosis and in two large angular deformities of the tibia after union, with a valgus of over 10 degrees and extremity shortening of over 2 cm which required additional surgery. Conclusion. External fixation by the use of Mitković external fixator is one of the methods of choice in the treatment of open segmental tibial fractures, which incorporated with antibiotic therapy provides good biomehanical conditions for segmental fracture healing that enables good stability of the segmental tibial fracture and decreases the risk of deep infections. [Projekat Ministarstva nauke Republike Srbije, br. 41017: Virtuelni koštano­zglobni sistem čoveka i njegova primena u pretkliničkoj i kliničkoj praksi

  13. Age Related Incidence and Early Outcomes of Hip Fractures: A Prospective Cohort Study of 1177 patients

    Directory of Open Access Journals (Sweden)

    Shenoy Ravikiran

    2011-01-01

    Full Text Available Abstract Introduction Associated with the increase in the aging population, there is an increase in the incidence of hip fractures worldwide. Outcome following such fractures is affected by age of the patient. This study aims to assess the incidence and early outcome of hip fractures, comparing between different age groups. Methods Data of hip fractures collected over a period of five years was analysed. Patients were divided into three groups, group A (patients under the age of 64, group B (patients between 65 and 84 years of age, and group C (patients over the age of 85. Results Of the 1177 patients included in the study, there were 90 patients in group A, 702 patients in group B and 385 patients in group C. There was a female preponderance across all age groups, and this increased as age advanced (p Conclusions Hip fractures are more common among females irrespective of age group. Older patients have a higher mortality and a greater deterioration of walking ability after such injuries. Internal fixation of intracapsular fractures have demonstrated satisfactory early outcome in the immediate period. This could be attributed to retention of native bone, better propioception and shorter operation time.

  14. Red Flags Are Missed in the Prevention of Hip Fractures: Baseline Results of the Zurich Hip Fracture Trial

    Science.gov (United States)

    From January 2005 to December 2007, we recruited 173 patients age 65 and older with acute hip fracture and a Folstein mini mental score of at least 15 into an ongoing double-blind RCT with vitamin D. 69% of hip fracture patients were admitted from home and 31% from institutions, 79% were women. Mean...

  15. Operative Cost Comparison: Plating Versus Intramedullary Fixation for Clavicle Fractures.

    Science.gov (United States)

    Hanselman, Andrew E; Murphy, Timothy R; Bal, George K; McDonough, E Barry

    2016-09-01

    Although clavicle fractures often heal well with nonoperative management, current literature has shown improved outcomes with operative intervention for specific fracture patterns in specific patient types. The 2 most common methods of midshaft clavicle fracture fixation are intramedullary and plate devices. Through retrospective analysis, this study performed a direct cost comparison of these 2 types of fixation at a single institution over a 5-year period. Outcome measures included operative costs for initial surgery and any hardware removal surgeries. This study reviewed 154 patients (157 fractures), and of these, 99 had intramedullary fixation and 58 had plate fixation. A total of 80% (79 of 99) of intramedullary devices and 3% (2 of 58) of plates were removed. Average cost for initial intramedullary placement was $2955 (US dollars) less than that for initial plate placement (Pcost for removal was $1874 less than that for plate removal surgery (P=.2). Average total cost for all intramedullary surgeries was $1392 less than the average cost for all plating surgeries (Pcost for all intramedullary surgeries requiring plate placement and removal was $653 less than the average cost for all plating surgeries that involved only placement (P=.04). Intramedullary fixation of clavicle fractures resulted in a statistically significant cost reduction compared with plate fixation, despite the incidence of more frequent removal surgeries. [Orthopedics.2016; 39(5):e877-e882.].

  16. A novel surgical tool for the revision hip arthroplasty due to neck stem’s fracture

    Science.gov (United States)

    Grivas, TB; Magnissalis, E; Papadakis, S

    2015-01-01

    During revision surgery of total hip arthroplasties, surgeons may come across the challenging complication of a proximally fractured femoral stem, which however maintains sufficient distal fixation. Such cases, although rare, are extremely demanding due to lack of available attachments that would assist surgical explantation of the broken implant. It is herein presented a metal sterilisable surgical tool designed for the removal of the femoral stem broken at the level of the “neck”. Hippokratia 2015; 19 (4): 352-355. PMID:27688701

  17. Biomechanical evaluation of fracture fixation constructs using a variable-angle locked periprosthetic femur plate system.

    Science.gov (United States)

    Hoffmann, Martin F; Burgers, Travis A; Mason, James J; Williams, Bart O; Sietsema, Debra L; Jones, Clifford B

    2014-07-01

    In the United States there are more than 230,000 total hip replacements annually, and periprosthetic femoral fractures occur in 0.1-4.5% of those patients. The majority of these fractures occur at the tip of the stem (Vancouver type B1). The purpose of this study was to compare the biomechanically stability and strength of three fixation constructs and identify the most desirable construct. Fifteen medium adult synthetic femurs were implanted with a hip prosthesis and were osteotomized in an oblique plane at the level of the implant tip to simulate a Vancouver type B1 periprosthetic fracture. Fractures were fixed with a non-contact bridging periprosthetic proximal femur plate (Zimmer Inc., Warsaw, IN). Three proximal fixation methods were used: Group 1, bicortical screws; Group 2, unicortical screws and one cerclage cable; and Group 3, three cerclage cables. Distally, all groups had bicortical screws. Biomechanical testing was performed using an axial-torsional testing machine in three different loading modalities (axial compression, lateral bending, and torsional/sagittal bending), next in axial cyclic loading to 10,000 cycles, again in the three loading modalities, and finally to failure in torsional/sagittal bending. Group 1 had significantly greater load to failure and was significantly stiffer in torsional/sagittal bending than Groups 2 and 3. After cyclic loading, Group 2 had significantly greater axial stiffness than Groups 1 and 3. There was no difference between the three groups in lateral bending stiffness. The average energy absorbed during cyclic loading was significantly lower in Group 2 than in Groups 1 and 3. Bicortical screw placement achieved the highest load to failure and the highest torsional/sagittal bending stiffness. Additional unicortical screws improved axial stiffness when using cable fixation. Lateral bending was not influenced by differences in proximal fixation. To treat periprosthetic fractures, bicortical screw placement should be

  18. Hip fractures. Epidemiology, risk factors, falls, energy absorption, hip protectors, and prevention

    DEFF Research Database (Denmark)

    Lauritzen, J B

    1997-01-01

    on the hip. Women with hip fractures have a lower body weight compared with controls, and they may also have less soft tissue covering the hip even when adjusted for body mass index, indicating a more android body habitus. Experimental studies show that the passive energy absorption in soft tissue covering...

  19. Internal Fixation of Femoral Neck Fractures : Treatment and effects

    NARCIS (Netherlands)

    S.M. Zielinski (Stephanie)

    2015-01-01

    markdownabstract__Abstract__ This thesis consists of three parts. Part 1 described aspects of the organization of trauma related trials. Part 2 analyzed the uniformity of current femoral neck fracture treatment and adherence to the Dutch guideline on hip fracture treatment. The implications of

  20. Review of a single contemporary femoral neck fracture fixation method in young patients.

    LENUS (Irish Health Repository)

    Henari, Shwan

    2011-03-01

    An intracapsular femoral neck fracture in a young patient is a rare and difficult injury to manage. The occurrence of complications following fixation is multifactorial. Initial displacement and timing and accuracy of reduction are the key factors affecting outcome. The severities of the trauma to the hip and the impact of the intracapsular hematoma also play a role, the importance of which remains poorly understood. The purpose of this study was to evaluate the high incidence of femoral neck fractures treated in our institution over a 7-month period, to record the long-term outcome of these patients, all of whom were treated with contemporary methods of internal fixation, and to highlight the reasons for this injury being termed an "orthopedic emergency" and its differences from the same injury in the elderly population. We performed a retrospective analysis of 12 cases of intracapsular femur neck fracture in patients younger than 50 years treated over 7 months in a regional trauma center. All patients underwent satisfactory reduction and fixation. Nine of the 12 patients had a good outcome at a mean follow-up of 29 months. One patient developed a nonunion of the femoral head requiring total hip arthroplasty, one developed avascular necrosis of the femoral head, and one developed partial avascular necrosis. This compares favorably with other studies.

  1. 股骨颈骨折直接行髋关节置换术与内固定失败后再行髋关节置换术的比较%Comparison of primary hip replacement with secondary replacement after failed internal fixation in the treatment of femoral neck fractures

    Institute of Scientific and Technical Information of China (English)

    王剑火; 张玉九; 李玉茂; 李平生

    2011-01-01

    Objective To explore the difference of the outcomes of primary hip replacement and secondary replacement after failed internal fixation in the treatment of femoral neck fractures for optimal choice of operation method for femoral neck fractures. Methods 43 patients with a secondary hip replacement after failed internal fixation (Group A) and 52 patients with a primary hip replacement (Group B) in the treatment of femoral neck fractures were retrospectively analyzed.All patients were followed up at least 2 years. Details of operation, complications, hip function and quality of life at 2 years after operation were compared between two groups. The hip function, including the pain movement and walking, was evaluated by the Charnley scoring system. The health-related quality of patients' life was evaluated by using the EQ-5D index. Results Operation time, amount of hemorrhage during operation, the Chamley score of hip function and EQ-5D index score of quality of life were 1.9±0.2 and 1.4±0.2h 、 525.6±50.8 and 462.3±47.8ml 、 13.4±2.3 and15.2±2.4 、 0.67±0.26 and 0.72±0.25 for Group A and Group B,respectively. The difference was significant for the above 4 respects (P<0.05).Conclusion The outcomes of secondary hip replacement after failed internal fixation is worse than those of primary hip replacement in the treatment of femoral neck fractures, which indicates that primary hip replacement is worth being recommended for patients with femoral neck fractures who are easier to develop to be a fracture nonunion or avascular necrosis of femoral head if they are treated with internal fixation.%目的 通过对股骨颈骨折直接行髋关节置换术与内固定失败后再行髋关节置换术临床结果的比较,为股骨颈骨折手术方式的选择提供依据.方法 回顾性分析随访2年的43例股骨颈骨折内固定失败后冉次行髋关节置换术(A组)和52例股骨颈骨折直接行髋关节置换术(B组)的临床资料,比较两组患者

  2. Biomechanical analysis of fracture fixation with external fixator in vivo

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Objective: To investigate the different ways of measuring the main axial strain during treatment with an external fixator and to find the suitable compression loaded by the external fixator at an early stage.Methods: Eighteen healthy big-ear rabbits were randomly divided into two groups according to different measuring methods: Group A and Group B. In Group A,a strain gauge was affixed to the external tibial cortex with 502 glue, and in Group B, a bone cement-coated strain gauge was installed on the internal tibial cortex. Groups A and B were divided into two subgroups A1, A2 and B1,B2, respectively, according to the pressure of half of and the same as the body weight. A Z-shaped left mid-shaft tibial osteotomy was performed and fixed by an external fixator. Results: The scaler curves of Group A changed dramatically during the early stage. The trendlines of the internal and external cortex went consistently after reaching the stable stage while the latter strain value was higher than the former. The time for Group B reaching the stable stage was short, but its absolute strain value was less than that of Group A. Before they were pressed to the stable stage, the declined speed of Subgroup A1 was more slowly than that of Subgroup A2 while the results of Subgroups B1 and B2 were same. Group A had an ascending trend after it declined while Group B didn't have. After they reached the stable stage, both Subgroups A1 and A2 had a declining trend while Subgroup A2 was more quickly than Subgroup Al, Subgroup B1 was kept at a definite level while Subgroup B2 fluctuated.Conclusions: The axial strain under external fixator can be measured by bone cement coated-strain gauge in vivo. The data may suggest that half of the body weight load was suitable for external fixator.

  3. Incidence and socioeconomic burden of hip fractures in Italy

    Directory of Open Access Journals (Sweden)

    A. Angeli

    2011-09-01

    Full Text Available Objectives: The aim of this study was to evaluate the trend of the incidence and costs of hip fractures in Italy. Methods: The incidence of hip fractures after 45 years of age in both females and males during the years 1999-2002 was obtained by analyzing the Italian Ministry of Health national hospitalization database, according to the diagnosis codes of International Classification of Diseases, Clinical Modification, 9° edition (IDC-9-CM that indicate femoral fracture. We have computed all direct costs sustained by the National Health Service for hospitalization and treatment of hip fractures on the basis of the value of the Diagnosis Related Groups (DRG referring to hip fractures. The expenses of rehabilitation and indirect expenses were based on estimates. Results: In 2002, more than 86,000 hip fractures were registered in Italy in male and female patients over 45 years old, with 9% progression compared to 1999; 77% were female and 80% were over 75 years of age. In 2002 the direct costs of hospitalization, in the patients over 65 years alone, were almost 400 milion euros, with an increase of 15% as compared to 1999. Considering also estimated rehabilitation costs, social aid and indirect costs, we estimate that hip fractures due to age-related osteoporosis created over a billion euros in expenses in 2002. Conclusions: Preventive intervention regarding the risk of hip fracture in elderly patients is urgent.

  4. Small bowel obstruction in percutaneous fixation of traumatic pelvic fractures

    Directory of Open Access Journals (Sweden)

    Roberto Bini

    2013-01-01

    Full Text Available The use of external fixation for the initial treatment of unstable, complex pelvic injuries with hemodynamic instability remains an effective treatment for multiply injured patients. Bowel entrapment within a pelvic fracture is a rarely reported, potentially fatal complication. Here, we report a polytrauma patient with pelvic fractures who developed an intestinal obstruction after an external fixation. At an explorative laparotomy, we found an ileum segment trapped in the sacral fracture. Reported cases of bowel entrapment in pelvic fractures, especially in sacral fractures, are exceedingly rare. The diagnosis is often delayed due to difficulty distinguishing entrapment from the more common adynamic ileus. In conclusion, clinicians and radiologists should be aware of this potentially lethal complication of pelvic fractures treatment. To exclude bowel entrapment, patients with persistent ileus or sepsis should undergo early investigations.

  5. Increased cortical porosity in women with hip fracture.

    Science.gov (United States)

    Sundh, D; Nilsson, A G; Nilsson, M; Johansson, L; Mellström, D; Lorentzon, M

    2017-05-01

    Hip fractures cause increased mortality and disability and consume enormous healthcare resources. Only 46% of hip fracture patients have osteoporosis at the total hip according to dual-energy X-ray absorptiometry (DXA) measurement. Cortical porosity increases with ageing and is believed to be important for bone strength. To investigate whether older women with hip fracture have higher cortical porosity than controls, and if so whether this difference is independent of clinical risk factors and areal bone mineral density (aBMD). From an ongoing population-based study, we identified 46 women with a prevalent X-ray-verified hip fracture and 361 control subjects without any fractures. aBMD was measured with DXA. High-resolution peripheral quantitative computed tomography was used to measure bone microstructure at the standard (ultradistal) site and at 14% (distal) of the tibial length. Women with a previous hip fracture had lower aBMD at the femoral neck (-11.8%) and total hip (-14.6%) as well as higher cortical porosity at the ultradistal (32.1%) and distal (29.3%) tibia compared with controls. In multivariable logistic regression analysis, with adjustment for covariates (age, height, weight, smoking, calcium intake, physical activity, walk time, oral glucocorticoids, parental hip fracture, rheumatoid arthritis, previous fall, current bisphosphonate treatment and femoral neck aBMD), cortical porosity at the ultradistal [odds ratio per standard deviation increase (95% confidence interval) 2.61 (1.77-3.85)] and distal [1.57 (1.12-2.20)] sites was associated with prevalent hip fracture. Cortical porosity was associated with prevalent hip fracture in older women independently of femoral neck aBMD and clinical risk factors. © 2017 The Authors. Journal of Internal Medicine published by John Wiley & Sons Ltd on behalf of Association for Publication of The Journal of Internal Medicine.

  6. Peripheral nerve blocks for hip fractures.

    Science.gov (United States)

    Guay, Joanne; Parker, Martyn J; Griffiths, Richard; Kopp, Sandra

    2017-05-11

    Various nerve blocks with local anaesthetic agents have been used to reduce pain after hip fracture and subsequent surgery. This review was published originally in 1999 and was updated in 2001, 2002, 2009 and 2017. This review focuses on the use of peripheral nerves blocks as preoperative analgesia, as postoperative analgesia or as a supplement to general anaesthesia for hip fracture surgery. We undertook the update to look for new studies and to update the methods to reflect Cochrane standards. For the updated review, we searched the following databases: the Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 8), MEDLINE (Ovid SP, 1966 to August week 1 2016), Embase (Ovid SP, 1988 to 2016 August week 1) and the Cumulative Index to Nursing and Allied Health Literature (CINAHL) (EBSCO, 1982 to August week 1 2016), as well as trial registers and reference lists of relevant articles. We included randomized controlled trials (RCTs) involving use of nerve blocks as part of the care provided for adults aged 16 years and older with hip fracture. Two review authors independently assessed new trials for inclusion, determined trial quality using the Cochrane tool and extracted data. When appropriate, we pooled results of outcome measures. We rated the quality of evidence according to the GRADE Working Group approach. We included 31 trials (1760 participants; 897 randomized to peripheral nerve blocks and 863 to no regional blockade). Results of eight trials with 373 participants show that peripheral nerve blocks reduced pain on movement within 30 minutes of block placement (standardized mean difference (SMD) -1.41, 95% confidence interval (CI) -2.14 to -0.67; equivalent to -3.4 on a scale from 0 to 10; I(2) = 90%; high quality of evidence). Effect size was proportionate to the concentration of local anaesthetic used (P mobilization after surgery (mean difference -11.25 hours, 95% CI -14.34 to -8.15 hours; I(2) = 52%; moderate quality of evidence). One trial

  7. Optimal fixation of oblique scaphoid fractures: a cadaver model.

    Science.gov (United States)

    Luria, Shai; Lenart, Lado; Lenart, Borut; Peleg, Eran; Kastelec, Matej

    2012-07-01

    Acute scaphoid fractures are commonly fixed with headless cannulated screws positioned in the center of the proximal fragment. Central placement of the screw may be difficult and may violate the scaphotrapezial joint. We hypothesize that placement of the screw through the scaphoid tuberosity will achieve perpendicular fixation of an oblique waist fracture and result in more stable fixation than a screw in the center of the proximal fragment. We designed oblique osteotomies for 8 matched pairs of cadaver scaphoids and fixed each specimen with a headless cannulated screw. In 1 specimen, we positioned the screw at the center of the proximal fragment; we placed its matched pair perpendicular to the fracture. The perpendicular screw was directed through the scaphoid tuberosity. We placed the specimen under the increasing load of a pneumatically driven plunger. We compared stiffness, load, distance at failure, and mechanism of failure between the central and perpendicular screw groups. We found no difference between groups. Stiffness was identical in both groups (131 N/mm) and load to failure was similar (central screw, 137 N vs perpendicular screw, 148 N). In this biomechanical model of an unstable scaphoid fracture, we found that similar stability of fixation had been achieved with a screw perpendicular to the fracture plane with entry through the tuberosity, compared with a screw in a central position in the proximal fragment. This study suggests that placing the screw through the tuberosity, perpendicular to a short oblique fracture, will not impair fixation stability. Percutaneous fixation of scaphoid fractures has become popular although it is technically challenging. An easier distal approach through the tuberosity, without violating the scaphotrapezial joint, may not impair the fixation stability of an oblique fracture. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  8. MRI assessment of the posterior acetabular wall fracture in traumatic dislocation of the hip in children

    Energy Technology Data Exchange (ETDEWEB)

    Rubel, Ivan F.; Kloen, Peter; Helfet, David L. [Department of Orthopaedic Surgery, Weill Medical College of Cornell University, New York, NY (United States); Potter, Hollis G. [MRI Department, Diagnostic Radiology, Hospital for Special Surgery, New York (United States)

    2002-06-01

    Traumatic hip dislocations associated with posterior wall fractures of the acetabulum in the pediatric population are in general a consequence of high-energy trauma. After expeditious reduction, instability mandates for further diagnosis and intervention. Plain radiographs or computerized tomography (CT) scans can misjudge the involvement of the posterior wall of the acetabulum due to the partially calcified nature of the pediatric bone. We present two cases of pediatric traumatic hip dislocation associated with posterior wall fractures of the acetabulum. In both cases, obvious postreduction instability was noted without conclusive findings of etiology on plain X-rays or CT scans. Magnetic resonance imaging (MRI) disclosed an extensive posterior wall traumatic involvement in both cases and helped to decide in favor of open reduction of the hip and internal fixation of the posterior wall fragment. (orig.)

  9. Reconstruction plate fixation of subtrochanteric femoral fractures in children.

    Science.gov (United States)

    El-Sayed, Moustafa; Abulsaad, Mazen; El-Hadidi, Mahmoud; El-Adl, Wael; El-Batouty, Magdy

    2007-08-01

    Pediatric subtrochanteric femoral fractures are rare and have received limited attention in the literature Treatment is controversial. Different treatment options are used: skin traction, 90/90 skeletal traction, spica casting, cast bracing, internal fixation and external fixation. The aim of this study is to present our results with internal fixation of subtrochanteric femoral fractures in children using a reconstruction plate. Between 2000 and 2004, eighteen patients with closed subtrochanteric femoral fractures were treated in the Mansoura Emergency Hospital. The average age at the time of injury was 8.2 years (range 5.3 years to 11.5 years). Pathological fractures and fractures associated with neuromuscular diseases were excluded from this study. Eight patients had head injuries and/or multiple injuries. In all cases a single 4.5 mm contoured reconstruction plate was used and a 6.5 mm cancellous screw was inserted through the plate into the femoral neck. Average follow-up was 38 months (range, 12 to 47 months). All fractures united with anatomical alignment within an average of 8 weeks (range 6 to 12 weeks). There were no deep infections and no significant limb length discrepancies. At the latest follow-up, no patient had any restriction of activities. Internal fixation with a reconstruction plate appears as a good treatment option for children with subtrochanteric femoral fractures.

  10. Early total hip arthroplasty for severe displaced acetabular fractures

    Institute of Scientific and Technical Information of China (English)

    YANG Shu-hua; ZHANG Yu-kun; XU Wei-hua; LI Jin; LIU Guo-hui; YANG Cao; LIU Yong; TIAN Hong-tao

    2006-01-01

    Objective : To investigate the effect of early total hip arthroplasty for severe displaced acetabular fractures.Methods: Total hip arthroplasty was performed on 17 cases of severe fracture of the acetabulum from 1997 to 2003. The mean follow-up was 2.1 years (1-6 years) and the average period from fracture to operation was 8 days (5-21 day). The average age of the patients was 53 years (26-69 years).Results: At the final follow-up the Harris hip score averaged 82(69-100) points and 15 cases have got a good outcome. There was one case of heterotopic bone formation. There were no radiographic evidences of late loosening of the prosthesis. One patient had severe central displacement of the cup.Conclusions: In patients with severe displaced acetabular fractures, particularly in elderly patients, early total hip arthroplasty is probably an alternative efficient way to achieve a painless and stable hip.

  11. High prevalence of simultaneous rib and vertebral fractures in patients with hip fracture.

    Science.gov (United States)

    Lee, Bong-Gun; Sung, Yoon-Kyoung; Kim, Dam; Choi, Yun Young; Kim, Hunchul; Kim, Yeesuk

    2017-02-01

    The purpose was to evaluate the prevalence and location of simultaneous fracture using bone scans in patients with hip fracture and to determine the risk factors associated with simultaneous fracture. One hundred eighty two patients with hip fracture were reviewed for this study. Clinical parameters and bone mineral density (BMD) of the lumbar vertebra and femoral neck were investigated. To identify acute simultaneous fracture, a bone scan was performed at 15.4±4.1days after hip fracture. The prevalence and location of simultaneous fracture were evaluated, and multivariate logistic regression analysis was performed to determine the risk factors. Simultaneous fracture was observed in 102 of 182 patients, a prevalence of 56.0%. Rib fracture was the most common type of simultaneous fracture followed by rib with vertebral fracture. The BMD of the lumbar vertebra was significantly lower in patients with simultaneous fracture (p=0.044) and was identified as an independent risk factor (odds ratio: OR 0.05, 95% confidence interval: CI 0.01-0.57). The prevalence of simultaneous fracture was relatively high among patients with hip fracture, and BMD was significantly lower in patients with simultaneous fracture than in patients without it. Surgeons should be aware of the possibility of simultaneous fracture in patients with hip fracture. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Internal fixation for coronal shear fracture of the capitellum with polylactide resorbable fixation

    Science.gov (United States)

    Kraan, Gerald A; Krijnen, Matthijs R; Eerenberg, Jan Peter

    2013-01-01

    A 24-year-old woman with pain in the right elbow after a fall demonstrated a coronal shear fracture on radiographic studies. Perioperative a coronal shear fracture was seen and treated successfully with a polylactide Rigid fix resorbable pin. The operative correction resulted in normal function at 6 months follow-up. We state that a capitellum shear fracture can be fixated with a single resorbable pin, leading to successful fusion. PMID:23378544

  13. Older peoples' lived experiences after hip fracture

    DEFF Research Database (Denmark)

    Rasmussen, Birgit; Uhrenfeldt, Lisbeth

    add to the load of wellbeing-challenges after HF. Evidence-based knowledge in order to address the wellbeing of older people and the challenges they meet in changing times after HF is needed for professionals. Aim To explore the support older people with HF may need to optimize their wellbeing during...... changes in their daily life. Method A PhD study is initiated conducting a systematic review; establishing a steering-group with hospital and community representatives in order to clarify organizational needs in a homecare setting; developing a phenomenological-hermeneutic study design guided......Background Older people's hip fracture (HF) may occur due to osteoporosis, impaired balance or other health problems. For the individual, the experience of changes in wellbeing and/or changes in a recent active everyday-life; new health problems such as dependency, pain and a fear of falling may...

  14. Physical Activity and Hip Fracture Disability: A Review

    Science.gov (United States)

    Marks, Ray

    2011-01-01

    Objective. The present paper examines pertinent literature sources published in the peer-reviewed English language between 1980 and November 1, 2010 concerning hip fractures. The aim was to highlight potential intervention points to offset the risk of incurring a hip fracture and its attendant disability. Methods. An in-depth search of the literature using the key terms: disability, epidemiology, hip fracture, prevention, and risk factors was conducted, along with data from the author's research base detailing the disability associated with selected hip fracture cases. All articles that dealt with these key topics were reviewed, and relevant data were tabulated and analyzed. Results. Hip fractures remain an important but potentially preventable public health problem. Among the many related remediable risk factors, low physical activity levels are especially important. Related determinants of suboptimal neuromuscular function also contribute significantly to hip fracture disability. Conclusion. Physical activity participation can help to reduce the prevalence and excess disability of hip fractures and should be encouraged. PMID:21584248

  15. Comparative study of the Ender method and Dynamic Hip Screw stabilization in the treatment of intertrochanteric fractures of the femur.

    Science.gov (United States)

    Walo, Roman; Semenowicz, Jacek; Grabowski, Marcin; Komarek, Marcin; Czuma, Przemysław

    2003-02-28

    Background. The aim of this retrospective study was to compare the results of two fixation devices (Ender rods in 118 patients and dynamic hip screw in 98 patients) for treatment of intertrochateric fractures of the hip. Material and methods. The two treatment groups were similar with respect to important preoperative variables such as age, coexisting disseases, bone quality and incidence of stable and unstable fractures. The following outcomes were assessed: quality of reduction, length of hospital stay, early mortality, reoperations, persistent pain at a knee or hip, decrease in range of motion of the knee and leg shortening. Results and conclusions. The subgroup analysis showed higher incidence of complications in patients with unstable type of fracture treated with Ender nailing. These complications included mainly valgus angulation and malrotation of the fracture, need for a secondary procedure due to loss of stabilization and knee pain. Intramedullary stabilization with Ender rods is not recommended in treatment of unstable intertrochanteric fractures of the femur.

  16. [Delirium prevention and treatment in elderly hip fracture].

    Science.gov (United States)

    Robles, María José; Formiga, Francesc; Vidán, M Teresa

    2014-04-22

    The fracture of the proximal femur or hip fracture in the elderly usually happens after a fall and carries a high morbidity and mortality. One of the most common complications during hospitalization for hip fracture is the onset of delirium or acute confusional state that in elderly patients has a negative impact on the hospital stay, and prognosis, worsening functional ability, cognitive status and mortality. Also the development of delirium during hospitalization increases health care costs. Strategies to prevent and treat delirium during hospitalization for hip fracture have been less studied. In this context, this paper aims to conduct a review of the literature on strategies that exist in the prevention and treatment of delirium in elderly patients with hip fracture.

  17. OCCURRENCE AND INCIDENCE OF THE 2ND HIP FRACTURE

    DEFF Research Database (Denmark)

    SCHRODER, HM; Petersen, KK; ERLANDSEN, M

    1993-01-01

    During a 16-year period, 256 second hip fractures were found in 3898 persons 40 years of age and older who had a previous hip fracture. Ninety-two percent of the second fractures were contra-lateral, and 68% of these were the same type as the first. Thus, 62% of the femoral neck and 72......% of the trochanteric fractures were preceded by a contra-lateral fracture of the same type. The mean interval between fractures was 3.3 years, and there was no significant difference between genders or among fracture types. The risk of the first fracture was 1.6 per 1000 men per year and 3.6 per 1000 women......, and for the second fracture 15 per 1000 men per year and 22 per 1000 women. This increase was highly significant for both genders, especially for men....

  18. Clinical Analysis of 65 Years of Age in Patients with Intertrochanteric Frac-tures of the Hip Joint Replacement and Internal Fixation%65岁以上股骨粗隆间骨折患者行髋关节置换和内固定术的临床分析

    Institute of Scientific and Technical Information of China (English)

    张登峰

    2015-01-01

    目的:探讨65岁以上股骨粗隆间骨折患者行髋关节置换和内固定术的临床疗效。方法选取60例2013年8月—2014年8月在该院接受治疗的65岁以上股骨粗隆间骨折患者,以随机方式将其平均分为两组,即对照组与观察组,对观察组患者实施髋关节置换术治疗,对对照组患者实施内固定术治疗。对比两组患者术后死亡率、并发症发生率、内置物松动率、髋部畸形率及髋关节功能评分等相关指标。结果术后观察组患者优良率为80.0%,对照组患者优良率为53.3%,观察组明显优于对照组,差异有统计学意义(P<0.05),观察组患者髋关节功能评分明显优于对照组,差异有统计学意义(P<0.05),但术后观察组患者死亡率显著高于对照组,差异有统计学意义(P<0.05);两组患者术后髋部畸形率、内科并发症发生率、内置物松动率,差异无统计学意义(P>0.05)。结论研究表明,内固定术与髋关节置换术治疗老年股骨粗隆间骨折患者均有其各自优势,需要对患者实际病情全面分析后才能决定所用治疗方法。%Objective To investigate the clinical efficacy of over 65 years in patients with intertrochanteric fractures hip replace-ment and internal fixation. Methods 60 August 2013 - August 2014 in our hospital treated 65 patients over the age of in-tertrochanteric fracture of the femur, in a random manner which were divided into two groups, namely the control group and the observation group, the observation group for patients with hip replacement therapy, patients in the control group on the implemen-tation of internal fixation. Comparison of postoperative mortality, morbidity, implant loosening, hip deformity and hip score and oth-er related indicators. Excellent results were observed in patients was 80.0%in the control group was 53.3%in patients with excel-lent observation group than the control group, P 0

  19. Optimal fixation of acute scaphoid fractures: finite element analysis.

    Science.gov (United States)

    Luria, Shai; Hoch, Sarah; Liebergall, Meir; Mosheiff, Ram; Peleg, Eran

    2010-08-01

    The hypothesis of this study was that more stable fixation of acute scaphoid fractures may be achieved by a screw placed perpendicular to the fracture plane than along the long axis of the scaphoid, as previously suggested. We examined this assumption on different fracture patterns using a finite element analysis model. A computed tomography scan of an intact scaphoid of a young man provided the data set for all fracture models. We used semiautomatic segmentation to create 3-dimensional computer models of the 3 simple fracture configurations: oblique, transverse waist, and proximal fractures, according to the Herbert classification. Each fracture type was analyzed, using finite elements, for its biomechanical response to 2 types of virtual fixation: a screw placed either perpendicular to the fracture plane or centrally along the long axis of the scaphoid. We measured motion at the fracture plane (in millimeters) and strain in the screw threads (in millipascals). Considerably less motion was measured at the fracture plane with the perpendicular screw compared with the long axis screw, especially in the oblique-type fractures: (1) Herbert-type B1 oblique fracture mean motion of 0.05 mm (+/-0.03) for the perpendicular screw versus 0.28 mm (+/-0.05) for the long axis screw; (2) B2 transverse waist fracture mean motion of 0.06 mm (+/-0.03) for the perpendicular screw versus 0.18 mm (+/-0.06) for the long axis screw; and (3) B3 proximal fracture mean motion of 0.07 mm (+/-0.01) for the perpendicular screw versus 0.28 mm (+/-0.011) for the long axis screw. Higher strains were measured on the screw placed perpendicular to the fracture. According to this model, higher fixation stability is achieved when the scaphoid is fixated perpendicular to the fracture. In transverse waist fractures, a centrally placed screw will also be perpendicular to the fracture, which explains the results of previous models. Copyright 2010. Published by Elsevier Inc.

  20. Influence of bone mineral density and hip geometry on the different types of hip fracture.

    Science.gov (United States)

    Li, Yizhong; Lin, Jinkuang; Cai, Siqing; Yan, Lisheng; Pan, Yuancheng; Yao, Xuedong; Zhuang, Huafeng; Wang, Peiwen; Zeng, Yanjun

    2016-01-01

    The aim of this study was to assess the influence of bone mineral density and hip geometry on the fragility fracture of femoral neck and trochanteric region. There were 95 menopausal females of age ≥ 50 years with fragility fracture of hip, including 55 cases of femoral neck fracture and 40 cases of trochanteric fracture. Another 63 non-fractured females with normal bone mineral density (BMD) were chosen as control. BMD, hip axis length, neck-shaft angle and structural parameters including cross surface area, cortical thickness and buckling ratio were detected and compared. Compared with control group, the patients with femoral neck fracture or trochanteric fractures had significantly lower BMD of femoral neck, as well as lower cross surface area and cortical thickness and higher buckling ratio in femoral neck and trochanteric region. There were no significant differences of BMD and structural parameters in the femoral neck fracture group and intertrochanteric fracture group. Hip axis length and neck-shaft angle were not significantly different among three groups. The significant changes of BMD and proximal femur geometry were present in the fragility fracture of femoral neck and trochanteric region. The different types of hip fractures cannot be explained by these changes.

  1. External fixation in early treatment of unstable pelvic fractures

    Institute of Scientific and Technical Information of China (English)

    HU San-bao; XU Hong; GUO Heng-bing; SUN Tong; WANG Chang-jun

    2012-01-01

    Background Patients with pelvic fractures are often treated in hospitals without the capacity to implement an open reduction internal fixation (ORIF).This often leads to pelvic malunion in patients with unstable pelvic fracture,shock or even death due to uncontrollable pelvic hemorrhage and unstable hemodynamics.This study explored the role of early external fixation (within 7 days) for patients with unstable pelvic fractures.Methods A retrospective analysis was conducted on 32 patients with unstable pelvic fractures treated with early external fixation from January 2005 to January 2010 (file type B:18 cases; C:14 cases).The study comprised 28 males and 4 females,with a mean age of (32±8) years (range,21-56 years).Of these patients,22 were treated with emergency pelvic external fixation and 10 were treated with external fixation within 1-7 days.Fifteen cases suffered traumatic hemorrhagic shock.A statistical analysis was conducted to compare fluid infusion and blood transfusion volumes within the first 24 hours of these shock patients with another cohort of patients treated without early external fixation from January 1993 to January 1998.Results The average follow-up was (34.7±14.6) months (range,6-66 months).Six to eight weeks after external fixation,patients could walk with crutches; by 12 weeks,external fixation was removed and all fractures had healed.Seven patients presented with sequelae,including 3 patients with long-term lumbosacral pain,3 patients with erectile dysfunction and 1 patient with Morel-Lavallee lesion and other complications.The 15 shock patients in this study (2005-2010 group) required significantly lower volumes of fluid infusion and blood transfusion (Pfluid=0.000;Ptransfusion=0.000) as compared to the 1993-1998 cohort.Conclusions The early application of external fixation in unstable pelvic fracture patients positively affects hemodynamic stability,with outstanding efficacy as a final fixation option for unstable pelvic fractures.

  2. Hip spica versus Rush pins for management of femoral diaphyseal fractures in children

    Directory of Open Access Journals (Sweden)

    Mohammad Ruhullah

    2014-01-01

    Full Text Available Background: Femoral fractures are common in children between 2 and 12 years of age and 75% of the lesions affect the femoral shaft. Traction followed by a plaster cast is universally accepted as conservative treatment. We compared primary hip spica with closed reduction and fixation with retrogradely passed crossed Rush pins for diaphyseal femur fracture in children. The hypothesis was that Rush pin might provide better treatment with good clinical results in comparison with primary hip spica. Materials and Methods: Fifty children with femoral fractures were evaluated; 25 of them underwent conservative treatment using immediate hip spica (group A and 25 were treated with crossed retrograde Rush pins (group B. The patients ages ranged from 3 to 13 years (mean of 9 years. Results: Mean duration of fracture union was 15 weeks in group A and 12 weeks in group B. Mean duration of weight bearing 14 weeks in group and 7 weeks in group B. Mean hospital stay was 4 days in group A and 8 days in group B. Mean followup period in group A was 16 months and group B was 17 months. Complications such as angulation, shortening, infection were compared. Conclusions: Closed reduction and internal fixation with crossed Rush pins was superior in terms of early weight bearing and restoration of normal anatomy.

  3. Plate fixation or intramedullary fixation of humeral shaft fractures

    NARCIS (Netherlands)

    Heineman, D.J.; Poolman, R.W.; Sean, S.E.N.; Ponsen, K.J.; Bhandari, M.

    2010-01-01

    Methods We performed a literature search from 1967 to November 2007 in the main medical search engines and selected 4 randomized trials that compared nails and plates in patients with humeral shaft fractures and that reported on complications due to surgery. We statistically pooled patient data

  4. The effects of liberal versus restrictive transfusion thresholds on ambulation after hip fracture surgery

    DEFF Research Database (Denmark)

    Foss, Nicolai B; Kristensen, Morten Tange; Jensen, Pia Søe;

    2009-01-01

    BACKGROUND: Perioperative anemia leads to increased morbidity and mortality and potentially inhibits rehabilitation after hip fracture surgery. As such, the optimum transfusion threshold after hip fracture surgery is unknown. PATIENTS AND METHODS: A total of 120 elderly, cognitively intact hip...

  5. Minimally invasive plate internal fixation for calcaneal fractures

    Institute of Scientific and Technical Information of China (English)

    SHAN Shu-lan; XU Jun-ling; YAO Shu-zhang; YU Guo-sheng; LIU Yu-qin

    2010-01-01

    Objective: To assess the clinical efficacy of minimally invasive plate internal fixation for the treatment of calcaneal fractures.Methods: Manual reduction, rectification of deformity,and cold compress with traditional Chinese medicine were used preoperatively to relieve swelling and pain. A small incision was made to expose the articular facet and to perform anatomic reduction and plate fixation. Self-made traditional Chinese pharmaceutics were applied postoperatively on the surface of the wound to accelerate bony union.Results: All the 40 patients were followed up for at least 1 year postoperatively. According to the Maryland scoring system, the excellent and good rate was 87.5%.Conclusion: Minimally invasive plate internal fixation has the advantages of relatively mild injury, reliable fixation,good recovery, and rare complications in the treatment of intraarticular fractures.

  6. Femoral Varus Osteotomy for Hip Instability after Traumatic Fracture Dislocations of the Hip Associated with Femoral Head Fractures: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Shuichi Miyamoto

    2016-01-01

    Full Text Available Fracture of the femoral head and the acetabulum with traumatic dislocation of the hip is a severe injury representing various types and unfavorable outcome. We showed a 45-year-old man with Pipkin type-IV fracture and coxa valga. An immediate closed reduction was achieved followed by open reduction and internal fixation via a posterior approach 6 days later. However, dislocation occurred three times without traumatic events after three weeks. CT demonstrated no displacement of posterior fragments or implant failure. Femoral intertrochanteric varus osteotomy was performed to gain concentric stability and successfully resolved recurrent dislocation. Another 45-year-old woman with Pipkin type-IV fracture and coxa valga also underwent closed reduction initially and then continued conservative treatment. After eight weeks, when she started gait training, progressive pain became symptomatic. Persistent hip pain at weight bearing was not improved in spite of arthroscopic synovectomy and osteochondroplasty. Two years after injury, femoral intertrochanteric varus osteotomy was indicated and her refractory pain was resolved gradually. We suggest that femoral varus osteotomy should be considered for superolateral subluxation associated fracture dislocation of the hip in Pipkin type-IV and coxa valga.

  7. Fibula fracture stabilization with a guide wire as supplementary fixation in tibia fractures.

    Science.gov (United States)

    Dombroski, Derek; Scolaro, John A; Pulos, Nicholas; Beingessner, Daphne M; Dunbar, Robert; Mehta, Samir

    2012-05-01

    The tibia is the most commonly fractured long bone. Although the goals of fracture management are straightforward, methods for achieving anatomical alignment and stable fixation are limited. Type of management depends on fracture pattern, local soft-tissue involvement, and systemic patient factors. Tibial shaft fractures with concomitant fibula fractures, particularly those at the same level, may be difficult to manage because of their inherent instability. Typically, management of lower extremity fractures is focused on the tibia fixation, and the associated fibula fracture is managed without fixation. In this article, we describe a novel technique for intramedullary fixation of the fibula, using a humeral guide wire as an adjunct to tibia fixation in the setting of tibial shaft fracture. This technique aids in determining length, alignment, and rotation of the tibia fracture and may help support the lower extremity as whole by stabilizing the lateral column. In addition, this technique can be used to help maintain reduction of the fibula when there is concern about the soft tissues of the lower extremity secondary to swelling or injury. Our clinical case series demonstrates the safety, effectiveness, and cost-sensitivity of this technique in managing select concurrent fractures of the tibia and fibula.

  8. Evaluation of Osteoporosis in Patients with Hip Fracture - Original Investigation

    Directory of Open Access Journals (Sweden)

    Firuzan Altın

    2007-03-01

    Full Text Available Aim: The aim of this study is to determine the state of osteoporosis and treatment in patients with osteoporotic hip fracture. Patients and Methods: 39 patients enrolled in this study that were above 50 years with an atraumatic hip fracture and operated in 1. and 2. Department of Orthopedics and Traumatology. Istanbul Training and Research Hospital, in our study (31 women, 8 men we investigate patients about risk factors of osteoporosis, before and after fracture severity of osteoporosis, treatment of osteoporosis. Patients who are younger than 50 years, and immobilized for long time, have pathological fracture, hip fracture is 2 cm distal than minor trochanter; are taken out from our study. Results: There is not significant difference between type of fracture, age, sex and risk factors. Before fractured 5 patients were diagnosed as osteoporosis and only 4 of them had been using antiresorptive, vitamin D, and calcium preparats. 36 patients that we studied never examined and treated for osteoporosis. All patients participating in study were informed about osteoporosis. Each patient was asked to apply for physical therapy and rehabilitation department with result of lumber and femoral bone mineral density measurement. Conclusion: Patients who had recent osteoporotic fractures must be treated to prevent new fracture. Orthopedic doctors should care osteoporosis and a new fracture risk as a serious important complication of osteoporotic hip fracture. (From the World of Osteoporosis 2007;13:11-4

  9. Biomechanical study of improved memory alloy embracing fixators in treatment of periprosthetic femoral fracture due to hip arthroplasty%改良记忆合金环抱器治疗髋关节置换术后股骨假体周围骨折的生物力学研究

    Institute of Scientific and Technical Information of China (English)

    孙强; 鲁尧; 王洪勋; 向帅

    2015-01-01

    Objective To study the mechanics of improved memory alloy fixators for salvage of periprosthetic femoral fracture (PFF) after hip arthroplasty in the elderly.Methods Thirty countrymen fresh cadaveric femurs with no pathological defect,fracture,deformity or tumor were randomly divided into experimental group and control group with 15 femurs in each according to the random number table.A model of Vancouver type B1 periprosthetic femoral fracture following hip arthroplasty was induced.The fracture was treated with modified memory alloy embracing fixators in experimental group;instead general memory alloy embracing fixators in control group.All specimens were tested biomechanically.Results Under the same mechanical loading,the two groups showed respective 30% and 48% maximum differences in stress value and displacement.Results in three-point bending test did not differ significantly between the two groups (P > 0.05),but there were significant differences in axial compression and torsion test (P < 0.05 or 0.01).Conclusion The improved memory alloy embracing fixators present better resistance to compression and torsion compared to the general fixators.%目的 对改良记忆合金环抱器治疗老年性髋关节置换术后股骨假体周围骨折(PFF)进行生物力学研究,分析改良记忆合金环抱器与普通记忆合金环抱器在生物力学方面的差异.方法 30根国人新鲜全长股骨纳入实验,所选择的标本证实无病理缺陷、骨折、畸形或肿瘤,按随机数字表法分为实验组(15根)和对照组(15根),依据Vancouver分型中B1型髋关节置换术后假体周围骨折建模.实验组采用改良记忆合金环抱器进行固定,对照组采用普通记忆合金环抱器进行固定.将股骨标本固定在生物力学试验机上进行力学对比测试.结果 当施加相同的载荷时,实验组和对照组的应变值最大可相差30%,两者的位移值最大可相差48%.实验组和对照组三点弯曲试

  10. Outcomes of post-operative periprosthetic acetabular fracture around total hip arthroplasty.

    Science.gov (United States)

    Pierce, Todd P; Cherian, Jeffrey J; Jauregui, Julio J; Elmallah, Randa D K; Mont, Michael A

    2015-05-01

    Post-operative periprosthetic acetabular fractures are rare, but serious complication following total hip arthroplasty (THA). As the number of THA performed each year increases so will the expected number of periprosthetic fractures, thus making the treatment of these fractures an important topic for discussion. The purpose of this review is to analyze the recent evidence on risk factors, fracture classification schemes and treatment strategies that have been used for periprosthetic acetabular fractures around THA. The modified Paprosky classification is the most widely used and is a useful guide for management strategies. This classification system provides the guidelines for developing multiple treatment algorithms for decision making. Treatment options for surgical management include open reduction and internal fixation with plating, use of reconstruction cages, trabecular metal augments and bone grafting as needed. Treatment decisions are still an area of controversy and current research.

  11. EXTERNAL FIXATOR IN THE MANAGEMENT OF UNSTABLE PELVIC FRACTURES

    Directory of Open Access Journals (Sweden)

    Devi prasad

    2014-08-01

    Full Text Available Universally, high- energy trauma is the major cause of mortality and morbidity in the younger age group. Usually pelvic fractures are caused by high energy trauma. Hence it affects not only the musculoskeletal system, but also the soft tissues and viscera contained in the pelvis leading to increased mortality and morbidity. Management of such patients remains a challenge to the trauma surgeon, even in the most sophisticated trauma centers. The aim of our study is to evaluate the role of external fixation in the management of pelvic fractures, both as a resuscitative measure and definitive treatment of unstable pelvic fractures (Type B & Type C. In our study, all patients underwent stabilization with external fixator and the mortality rate was zero with additional internal fixation with reconstruction plating being done in three patients. The primary advantage of external fixation in pelvic injury is to maintain the reduction by which it produces a tamponade effect and results in reduction in haemorrhage, and helps transportation of the patient. External stabilization for unstable pelvic fractures with external fixator is an established treatment procedure and we in our study confirm the usefulness of the procedure in an emergency situation and can be continued effectively as a definitive management for type B & C Pelvic injuries

  12. Missed opportunities for prevention of hip fracture in older patients

    Directory of Open Access Journals (Sweden)

    Dubljanin-Raspopović Emilija

    2012-01-01

    Full Text Available Background/Aim. Osteoporotic fractures are a major cause of morbidity in the population. Therefore, fracture prevention strategies should be a major concern, and one of the priorities in the primary health care system. The aim of the study was to assess fracture and fall risk factors, and fracture risk level in patients with acute hip fracture, and to evaluate if there had been adequate osteoporosis treatment prior to fracture in this group of patients. Methods. Fracture and fall risk factors were assessed in 342 patients, ≥ 65 years old, hospitalized due to acute hip fracture at the Clinic for Orthopedic Surgery and Traumatology, Clinical Centre of Serbia in a 12-month period. Fall risk factors were assessed with the Fracture Risk Assessment (FRAX® algorithm, and patients were classified in respect to fracture risk level. Results. Hip fracture occurred in the majority of the patients in the high risk group (74.2%, where no additional bone mineral density testing was needed. Less than 10% of the patients had a diagnosis of osteoporosis before injury, while less than 2% were treated. Cognitive impairment (95.3%, visual impairment (58.2%, lower index of daily activities (51.8%, and depression (47.1% were the most frequently observed fall risk factors. Conclusion. The results of our investigation reveal insufficient identification of clinical fracture risk factors in the primary care setting, inadequate treatment of osteoporosis and, consequently, ineffective prevention of hip fractures in the geriatric population. The introduction of FRAX® into clinical practice enables more effective acknowledgment of patients with elevated fracture risk, even if bone density measurement is not available. The results of this study have a special significance for everyday clinical practice, because they impose a need for reviewing the existing approaches to osteoporosis prevention, and precise definiment of hip prevention strategies.

  13. Closed Reduction and Percutaneous Fixation of Calcaneal Fractures in Children.

    Science.gov (United States)

    Feng, Yongzeng; Yu, Yang; Shui, Xiaolong; Ying, Xiaozhou; Cai, Leyi; Hong, Jianjun

    2016-07-01

    Open reduction and internal fixation has been widely used to treat displaced intra-articular calcaneus fractures in children. However, the complications of surgical trauma and the wound created through the extended lateral approach cannot be ignored. This study analyzed the outcomes of displaced intra-articular calcaneal fractures in children treated with closed reduction and percutaneous fixation. Medical records of pediatric patients who had displaced intra-articular calcaneus fractures and underwent closed reduction and percutaneous fixation at the study institution between January 2008 and January 2013 were reviewed. Preoperative radiographs and computed tomography scans were used to evaluate and classify the fractures. Clinical outcomes and radiographic findings were assessed at postoperative follow-up. The study included 14 displaced intra-articular calcaneal fractures in 11 patients (7 boys and 4 girls). Mean patient age was 11.18 years (range, 6-16 years), and average follow-up time was 42.8 months postoperatively (range, 12-72 months). There were 6 tongue-type fractures and 8 joint depression-type fractures, based on the Essex-Lopresti classification, and there were 11 type II and 3 type III fractures, based on the Sanders classification. Average Böhler angle was 8.00° (range, -5° to 18°) preoperatively and 30.79° (range, 26° to 40°) postoperatively (P<.001). Average subjective American Orthopaedic Foot and Ankle Society hindfoot score was 65.7 (range, 52-68). No patients had wound breakdown or infection. In the treatment of displaced intra-articular calcaneal fractures in pediatric patients, closed reduction and percutaneous fixation achieved good outcomes, with few complications. [Orthopedics. 2016; 39(4):e744-e748.]. Copyright 2016, SLACK Incorporated.

  14. The dynamic locking blade plate, a new implant for intracapsular hip fractures: biomechanical comparison with the sliding hip screw and Twin Hook.

    Science.gov (United States)

    Roerdink, W H; Aalsma, A M M; Nijenbanning, G; van Walsum, A D P

    2009-03-01

    Internal fixation of intracapsular hip fractures results in a high failure rate with non-union and avascular necrosis being the two most important complications. In order to prevent these possible complications treatment should consist of an anatomical reduction and stable fixation by insertion of a low volume, dynamic implant, providing angular and rotational stability to the femoral head. According to these principles a new implant, the dynamic locking blade plate (DLBP) was designed for the fixation of intracapsular hip fractures. We performed a biomechanical analysis in synthetic bone to compare the rotational stability and cut out resistance of the DLBP with a conventional sliding hip screw (SHS) and the more recently developed Twin Hook. The rotational stability of the DLBP proved to be three times higher than the rotational stability of a SHS and two times higher than the Twin Hook. There was no major difference in cut out resistance between the different implants. The design of the DLBP and possible advantages with regard to the healing of an intracapsular hip fracture are discussed.

  15. Simultaneous Periprosthetic Fractures of the Femur and the Acetabulum After Bipolar Hip Arthroplasty

    Science.gov (United States)

    Verettas, Dionysios-Alexandros; Chloropoulou, Pelagia-Paraskevi; Drosos, Georgios; Vogiatzaki, Theodosia; Tilkeridis, Konstantinos; Kazakos, Konstantinos

    2016-01-01

    Patient: Female, 68 Final Diagnosis: Periprosthetic fractures of the acetabulum and femur after bipolar hip arthroplasty Symptoms: Inability to walk Medication: — Clinical Procedure: Revision cup and internal fixation femur Specialty: Orhopedics and Traumatology Objective: Rare co-existance of disease or pathology Background: Although periprosthetic fractures of the femur are a recognized complication of total hip arthroplasty, periprosthetic fractures of the acetabulum are rare. Simultaneous periprosthetic fractures of both the acetabulum and the femur have not been reported, to our knowledge. Case Report: We report a simultaneous fracture of the acetabulum and the femur in a 68-year-old female patient who had previously sustained a subcapital fracture of the femur, treated with a bipolar uncemented prosthesis. We discuss the possible mechanism of this combination of fractures. Conclusions: Simultaneous periprosthetic fractures of the femur and the acetabulum can occur if, in the presence of osteoporotic bone, the metallic femoral head has migrated medially in the acetabulum while the femoral stem is not loose. PMID:28003639

  16. Post-operative rounds by anaesthesiologists after hip fracture surgery

    DEFF Research Database (Denmark)

    Foss, N B; Christensen, D S; Krasheninnikoff, M

    2006-01-01

    Efforts to optimize the peri-operative care of hip fracture patients through multidisciplinary intervention have focused on orthopaedic-geriatric liaisons, which have not resulted in significant outcome changes. The early phase of rehabilitation could potentially be optimized through...

  17. Focal osteoporosis defects play a key role in hip fracture.

    Science.gov (United States)

    Poole, Kenneth E S; Skingle, Linda; Gee, Andrew H; Turmezei, Thomas D; Johannesdottir, Fjola; Blesic, Karen; Rose, Collette; Vindlacheruvu, Madhavi; Donell, Simon; Vaculik, Jan; Dungl, Pavel; Horak, Martin; Stepan, Jan J; Reeve, Jonathan; Treece, Graham M

    2017-01-01

    Hip fractures are mainly caused by accidental falls and trips, which magnify forces in well-defined areas of the proximal femur. Unfortunately, the same areas are at risk of rapid bone loss with ageing, since they are relatively stress-shielded during walking and sitting. Focal osteoporosis in those areas may contribute to fracture, and targeted 3D measurements might enhance hip fracture prediction. In the FEMCO case-control clinical study, Cortical Bone Mapping (CBM) was applied to clinical computed tomography (CT) scans to define 3D cortical and trabecular bone defects in patients with acute hip fracture compared to controls. Direct measurements of trabecular bone volume were then made in biopsies of target regions removed at operation. The sample consisted of CT scans from 313 female and 40 male volunteers (158 with proximal femoral fracture, 145 age-matched controls and 50 fallers without hip fracture). Detailed Cortical Bone Maps (c.5580 measurement points on the unfractured hip) were created before registering each hip to an average femur shape to facilitate statistical parametric mapping (SPM). Areas where cortical and trabecular bone differed from controls were visualised in 3D for location, magnitude and statistical significance. Measures from the novel regions created by the SPM process were then tested for their ability to classify fracture versus control by comparison with traditional CT measures of areal Bone Mineral Density (aBMD). In women we used the surgical classification of fracture location ('femoral neck' or 'trochanteric') to discover whether focal osteoporosis was specific to fracture type. To explore whether the focal areas were osteoporotic by histological criteria, we used micro CT to measure trabecular bone parameters in targeted biopsies taken from the femoral heads of 14 cases. Hip fracture patients had distinct patterns of focal osteoporosis that determined fracture type, and CBM measures classified fracture type better than a

  18. Incidence of Hip Fractures among Iranian Elderly Population

    Directory of Open Access Journals (Sweden)

    A Moayyeri

    2004-03-01

    Full Text Available Hip fracture, the most dramatic complication of osteoporosis, constitutes a serious health problem of the elderly, with great socioeconomic consequences. Hip fracture epidemiology has been studied by many investigators. Until now, there are no reported studies in Iran regarding this issue. We studied hip fractures that occurred in Iran in 2003 and compared the findings with those of other countries. Data used were obtained from the Iranian Multicenter Study on Accidental Injuries, a large-scale population-based study conducted in 9 provinces across the country. The study was conducted by the Ministry of Health and Medical Education and continued for 135 days (4.5 months in all centers, beginning in a date between 15 June 2003 and 15 July 2003 for each center. A total of 1482 new cases of hip fracture (1079 male, 403 female were recorded during the study period. The crude annual incidence of hip fracture (per 100000 person-years was 59.8 in men and 23.5 in women. The incidence rates increased exponentially after the age of 60 in both genders and nearly tripled after each decade. In comparison with hip fracture incidence rates of other countries, Iranian rates are considerably lower than other Asian, European, and American countries. The reasons for this low incidence rate remain uncertain. With increase in life span, rapid economic development and aging of the population, hip fracture will become a major health problem in Iran and studies are needed to increase awareness of osteoporosis and to monitor the epidemiology of hip fractures.

  19. Distinct Cognitive Trajectories in the First Year After Hip Fracture

    NARCIS (Netherlands)

    Beishuizen, Sara J. E.; van Munster, Barbara C.; de Jonghe, Annemarieke; Abu-Hanna, Ameen; Buurman, Bianca M.; de Rooij, Sophia E.

    ObjectivesChange in cognitive functioning is often observed after hip fracture. Different patterns, with both improvement and decline, are expected, depending on premorbid cognitive functioning and events that occur during hospitalization. These patterns are unknown and important for older hip

  20. Novel fixation method of a periprosthetic fracture of the acetabulum using burr holes through the retained cup for locking screw fixation.

    Science.gov (United States)

    Browne, James A; Weiss, David B

    2015-03-01

    The incidence of periprosthetic fractures of the acetabulum associated with a total hip arthroplasty is relatively low but may be increasing. Treatment options depend upon the stability of the prosthesis. In this case, we report an unusual fracture pattern where a large portion of posterior column remained osseointegrated to a displaced uncemented acetabular component and removal of the cup would have resulted in massive structural bone loss and potential pelvic discontinuity. A metal cutting burr was used to create additional screw holes in the cup to allow us to retain the original implant and also obtain fixation of the fracture. The patient had a good outcome at one year with a healed fracture, stable implant, and excellent function. To our knowledge, this technique has not been previously described and offers surgeons an approach to fix these challenging fractures.

  1. Biomechanical rationale for implant choices in femoral neck fracture fixation in the non-elderly.

    Science.gov (United States)

    Panteli, Michalis; Rodham, Paul; Giannoudis, Peter V

    2015-03-01

    Femoral neck fractures represent a relatively uncommon injury in the non-elderly population often resulting from high-energy trauma. The cornerstone of their management is anatomic reduction and stable internal fixation of the femoral neck in an attempt to salvage the femoral head. Complications including avascular necrosis of the femoral head, non-union and post-traumatic osteoarthritis are not uncommon. The clinical outcomes of these patients can be improved with good pre-operative planning, optimization of surgical procedures and introduction of new improved implants and techniques. In the herein study, we attempt to describe the biomechanical properties of the hip and compare the performance of the most commonly used devices. Experimental evidence suggests that in Pauwels type III fracture patterns a cephalomedullary nail was significantly stronger in axial loading. Moreover, in unstable basicervical patterns cannulated screws (triangular configuration) demonstrated a lower ultimate load to failure, whereas in subcapital or transervical patterns both the cannulated screws (triangular configuration) and the sliding hip screw demonstrated no compromise in fixation strength. The fracture pattern appears to be the major determinant of the ideal type of implant to be selected. For a successful outcome each patient needs to be considered on an individual basis taking into account all patient and implant related factors.

  2. Application of SGD Fixator in Fractures of Tibia and Fibula

    Institute of Scientific and Technical Information of China (English)

    PING Jinzhong; SHEN Hongsheng; QIU Song

    2002-01-01

    @@ We applied SGD unilateral multifunctional external fixators(designed by Prof. Yu Zhongjia and produced by Shanghai Surgical Instruments Factory) to treat open, closed and ununited fractures of tibia and fibula caused by trauma in our hospital from Jan. 1994 to Dec. 1998. 3 months to one year after operation, the fractures were united and the satisfying results were obtained. Our reports were as follows.

  3. Factors affecting functional prognosis of patients with hip fracture

    DEFF Research Database (Denmark)

    Kristensen, M T

    2011-01-01

    . A variety of factors such as age, prefracture function and health status, fracture type, pain, anaemia, muscle strength, and the early mobility level have been shown to influence patient outcome. Thus, the outcome of patients with hip fracture is considered multi-factorial, and can therefore not be related......Having a hip fracture is considered one of the most fatal fractures for elderly people, resulting in impaired function, and increased morbidity and mortality. This challenges clinicians in identifying patients at risk of worse outcome, in order to optimise and intensify treatment in these patients...... to just one or two single factors. The current article reviews important factors affecting the functional prognosis, and clinicians are encouraged to include all factors potentially influencing the outcome of patients with hip fracture in their individualised treatment and rehabilitation plan. Especially...

  4. Caffeine and the risk of hip fracture: the Framingham Study.

    Science.gov (United States)

    Kiel, D P; Felson, D T; Hannan, M T; Anderson, J J; Wilson, P W

    1990-10-01

    Caffeine increases urinary calcium output and has been implicated as a risk factor for osteoporosis. The authors examined the effect of caffeine on hip fracture risk in 3,170 individuals attending the 12th (1971-1973) Framingham Study examination. Coffee and tea consumption, age, Framingham examination number, weight, smoking, alcohol consumption, and estrogen use were used to evaluate hip fracture risk according to caffeine intake. Hip fractures occurred in 135 subjects during 12 years of follow-up. Fracture risk over each 2-year period increased with increasing caffeine intake (one cup of coffee = one unit of caffeine, one cup of tea = 1/2 unit of caffeine). For intake of 1.5-2.0 units per day, the adjusted relative risk (RR) of fracture was not significantly elevated compared with intake of one or less units per day. Consumption of greater than or equal to 2.5 units per day significantly increased the risk of fracture. Overall, intake of greater than two cups of coffee per day (four cups of tea) increased the risk of fracture. In summary, hip fracture risk was modestly increased with heavy caffeine use, but not for intake equivalent to one cup of coffee per day. Since caffeine use may be associated with other behaviors that are, themselves, risk factors for fracture, the association may be indirect. Further studies should be performed to confirm these findings.

  5. External fixation in the treatment of open tibial shaft fractures

    Directory of Open Access Journals (Sweden)

    Golubović Zoran

    2008-01-01

    Full Text Available Background/Aim. Besides the conquasant fractures, open tibia shaft fractures belong to the group of the most severe fractures of tibia. Open tibia shaft fracture is one of the most common open fractures of long bones. They most frequently occur as a result of traffic accidents caused by the influence of a strong direct force. Methods. Within the period from January, 2000 to December 31, 2005. at the Clinic for Orthopaedics and Traumatology, Clinical Center Nis, 107 patients with open tibial fractures were treated. We analyzed 96 patients with open tibial fracture. In the series analyzed, the male sex was prevalent - there were 74 men (77.08%. The mean age was 47.3 years. The youngest patient was 17 years old, while the oldest patient was 79. According to the classification of the Gustilo et al. in the analysed group there were 30 (31.25% open tibial fractures of the I degree, 31 (32.29% of the II degree, 25 (26.05% of the III A degree, 8 (8.33% of the III B degree and 2 (2.08% of the III C degree. In 95 of the patients the treatment of open tibia shaft fractures consisted of the surgical treatment of wound and the external fixation of the fractured bone using "Mitkovic" type external fixator with a convergent method of pin applications. One primary amputations had been done in patients with grade IIIC open tibial fracture with large soft tissue defect. Results. Of the 96 open tibial fractures available for follow-up, 73 (76.04% healed without severe complications (osteitis, pseudoarthrosis, valgus malunion and amputation. Ther were nine (9.38% soft tissue pin track infections and six (6.25% superficial wound infections. The mean time of union was 21 (14-36 week. Among severe local complications associated with open tibial fractures, in eight patients (8.33% was registered osteitis, and in nine patients (9.38% fracture nonunion and the development of pseudoarthrosis. Three of the patients (3.13% had more than 10 degree valgus malunion. In one

  6. Contralateral reversed distal femoral locking plate for fixation of subtrochanteric femoral fractures

    Institute of Scientific and Technical Information of China (English)

    Paritosh Gogna; Reetadyuti Mukhopadhyay; Amanpreet Singh; Ashish Devgan; Sahil Arora; Amit Batra; Sushil Kumar Yadav

    2015-01-01

    Purpose:Subtrochanteric fractures of the femur are being managed successfully with various intramedullary and extramedulary implants with reasonable success.However,these implants require precise placement under image intensifier guidance,which exposes the surgeon to substantial amount of radiation.It also restricts the management of these fractures at peripheral centers where facility of image intensifiers is not available.Keeping this in mind we designed this study to identify if contralateral reversed distal femoral locking plate can be used successfully without the use of image intensifier.Methods:Twenty-four consecutive patients (18 men and 6 women) with a mean age of 28 years (range 19-47 years) suffering subtrochanteric fractures of the femur underwent open reduction and internal fixation with reversed contralateral distal femoral locking plate.The outcome was assessed at the mean follow-up period of 3.2 years (range 2-4.6 years) using the Harris hip score.Results:Twenty-one fractures united with the primary procedure,with a mean time of consolidation being 11 weeks (range,9-16 weeks).One patient developed superficial suture line infection,which resolved with oral antibiotics.Another patient had a fall 3 weeks after surgery and broke the plate.Repeat surgery with reversed distal femoral locking compression plate was performed along with bone grafting and the fracture united.Two cases had nonunion,which went in for union after bone grafting.The mean Harris hip score at the time of final follow-up was 90.63 (range 82-97).Conclusion:The reversed contralateral distal femoral plate is a biomechanically sound implant,which when used for fixation of the subtrochanteric fractures with minimal soft tissue stripping shows results comparable to those achieved by using other extramedullary implants as well as intramedullary devices.The added advantage of this implant is its usability in the absence of an image intensifier.

  7. Biomechanical stability of four fixation constructs for distal radius fractures.

    Science.gov (United States)

    Capo, John T; Kinchelow, Tosca; Brooks, Kenneth; Tan, Virak; Manigrasso, Michaele; Francisco, Kristin

    2009-09-01

    Implants available for distal radius fracture fixation include dorsal nonlocked plating (DNLP), volar locked plating (VLP), radial-ulnar dual-column locked plating (DCPs), and locked intramedullary fixation (IMN). This study examines the biomechanical properties of these four different fixation constructs. In 28 fresh-frozen radii, a wedge osteotomy was performed, creating an unstable fracture model and the four fixation constructs employed (DNLP, VLP, DCPs, and IMN). Dorsal bending loads were applied and bending stiffness, load to yield 5 mm displacement, and ultimate failure were measured. Bending stiffness for VLP (16.7 N/mm) was significantly higher than for DNLP (6.8 N/mm), while IMN (12.6 N/mm) and DCPs (11.8 N/mm) were similar. Ultimate load to failure occurred at 278.2 N for the VLP, 245.7 N for the IMN, and 52.0 N for the DNLP. The VLP was significantly stronger than the DNLP and DCPs, and the IMN and DCPs were stronger than the DNLP. The VLP has higher average bending stiffness, ultimate bending strength, and resistance to 5 mm displacement than the other constructs and significantly higher ultimate bending strength than the DCPs and DNLP. There was no statistically significant difference between the VLP and IMN. VLP and IMN fixation of distal radius fractures can achieve comparable stability.

  8. Displaced anterior cruciate ligament avulsion fractures: Arthroscopic staple fixation

    Directory of Open Access Journals (Sweden)

    S R Sundararajan

    2011-01-01

    Full Text Available Background: Anterior cruciate ligament (ACL avulsion fracture is commonly associated with knee injuries and its management is controversial ranging from conservative treatment to arthroscopic fixation. The aim of our study was to assess the clinical and radiological results of arthroscopic staple fixation in the management of ACL avulsion fractures. Materials and Methods: Twenty-two patients (17 males and 5 females who underwent arthroscopic staple fixation for displaced ACL avulsion fractures were analysed. The mean age was 32.2 years (15-55 years with a mean followup of 21 months (6-36 months. All patients were assessed clinically by calculating their Lysholm and International Knee Documentation Committee (IKDC scores and the radiological union was assessed in the followup radiographs. Results: The mean Lysholm score was 95.4(83-100 and the mean IKDC score was 91.1(77-100 at the final followup. In 20 patients anterior drawer′s test was negative at the end of final followup while two patients had grade I laxity. Associated knee injuries were found in seven cases. The final outcome was not greatly influenced by the presence of associated injuries when treated simultaneously. At final followup all the patients were able to return to their pre-injury occupation Conclusion: Arthroscopic staple fixation is a safe and reliable method for producing clinical and radiological outcome in displaced ACL avulsion fractures.

  9. Functional Outcome of Internal Fixation of Radial and Ulna Fracture

    Directory of Open Access Journals (Sweden)

    mehrdad Mansouri

    2006-02-01

    Conclusion: Anatomic reduction and internal fixation is the standard method for treatment of fractures by displacing radios and ulna in adults. According to results, it seems more intension to motions specially pronation and muscle strengthening foream after surgery will have affect on improving patients’ function specially pronation and Grip strength.

  10. Increased Fracture Collapse after Intertrochanteric Fractures Treated by the Dynamic Hip Screw Adversely Affects Walking Ability but Not Survival

    Directory of Open Access Journals (Sweden)

    Christian Fang

    2016-01-01

    Full Text Available In osteoporotic hip fractures, fracture collapse is deliberately allowed by commonly used implants to improve dynamic contact and healing. The muscle lever arm is, however, compromised by shortening. We evaluated a cohort of 361 patients with AO/OTA 31.A1 or 31.A2 intertrochanteric fracture treated by the dynamic hip screw (DHS who had a minimal follow-up of 3 months and an average follow-up of 14.6 months and long term survival data. The amount of fracture collapse and shortening due to sliding of the DHS was determined at the latest follow-up and graded as minimal (2 cm. With increased severity of collapse, more patients were unable to maintain their premorbid walking function (minimal collapse = 34.2%, moderate = 33.3%, severe = 62.8%, and p=0.028. Based on ordinal regression of risk factors, increased fracture collapse was significantly and independently related to increasing age (p=0.037, female sex (p=0.024, A2 fracture class (p=0.010, increased operative duration (p=0.011, poor reduction quality (p=0.000, and suboptimal tip-apex distance of >25 mm (p=0.050. Patients who had better outcome in terms of walking function were independently predicted by younger age (p=0.036, higher MMSE marks (p=0.000, higher MBI marks (p=0.010, better premorbid walking status (p=0.000, less fracture collapse (p=0.011, and optimal lag screw position in centre-centre or centre-inferior position (p=0.020. According to Kaplan-Meier analysis, fracture collapse had no association with mortality from 2.4 to 7.6 years after surgery. In conclusion, increased fracture collapse after fixation of geriatric intertrochanteric fractures adversely affected walking but not survival.

  11. Hip axis length is a FRAX- and bone density-independent risk factor for hip fracture in women.

    Science.gov (United States)

    Leslie, William D; Lix, Lisa M; Morin, Suzanne N; Johansson, Helena; Odén, Anders; McCloskey, Eugene V; Kanis, John A

    2015-05-01

    Bone mineral density (BMD) measurement from dual-energy X-ray absorptiometry (DXA) is widely used to assess skeletal strength in clinical practice, but DXA instruments can also measure biomechanical parameters related to skeletal shape. The objective of the study was to determine whether DXA-derived hip geometry measures provide information on fracture prediction that is independent of hip fracture probability determined from the fracture risk assessment tool (FRAX) algorithm. This was a retrospective registry study using BMD results for Manitoba, Canada. Women aged 40 years and older with baseline hip DXA, derived hip geometry measures, and FRAX scores (n = 50 420) participated in the study. Hospitalized hip fracture (n = 1020) diagnosed during 319 137 person-years of follow-up (median 6.4 y) was measured. Among the hip geometry measures, hip axis length (HAL) showed a consistent association with hip fracture risk when adjusted for age [hazard ratio (HR) 1.30 per SD increase, 95% confidence interval (CI) 1.22-1.38], and this was unaffected by further adjustment for BMD or FRAX score. Adjusted for FRAX score with BMD, there was a significant effect of increasing HAL quintile on hip fracture risk (linear trend P hip geometry measurements are associated with incident hip fracture risk, but many do not confer significant independent predictive information. HAL was found to predict hip fractures when adjusted for BMD or FRAX score and may be of clinical value in refining hip fracture risk.

  12. Open Reduction and Internal Fixation of Mandibular Fracture without Rigid Maxillomandibular Fixation

    Directory of Open Access Journals (Sweden)

    El-Anwar, Mohammad Waheed

    2015-03-01

    Full Text Available Introduction The ability to treat fracture with open reduction and internal fixation (OR/IF has dramatically revolutionized the approach to mandible fracture. With OR/IF, the postoperative role of rigid maxillomandibular fixation (MMF has declined, but it is used to maintain proper occlusion until internal fixation of the fracture is achieved. Objective To assess intraoperative manual MMF during OR/IF of selected cases of mandibular fractures. Methods This prospective study was conducted on 80 patients with isolated mandibular fractures managed by OR/IF using two titanium miniplates. The patients were classified into two groups: a control group (40 patients treated by OR/IF after intraoperative rigid MMF followed by immediate MMF removal, and a study group (40 patients treated by rigid MMF, which was replaced by temporary intraoperative manual MMF (3MF until plate fixation. Results There were no significant differences of the postoperative complication and dental occlusion, although a highly significant reduction of operative time was achieved in the 3MF group. Patient who received the 3MF technique had statistically significantly better average intrinsic vertical mouth opening in the early postoperative period (1 week after surgery, and normal mouth opening could be achieved in all cases in both groups 8 weeks after surgery. Conclusions Intraoperative rigid MMF is not mandatory and can be replaced in selected cases of fracture mandible by manual maintenance of proper dental occlusion until hardware fixation, gaining the advantages of shorter operative time and less risk of blood-transmitted diseases to the surgical team and the patient in addition to the benefits of immediate postoperative mandible mobilization.

  13. Low bone mineral density is not related to failure in femoral neck fracture patients treated with internal fixation

    DEFF Research Database (Denmark)

    Viberg, Bjarke; Ryg, Jesper; Overgaard, Søren;

    2014-01-01

    Background and purpose - Internal fixation (IF) in femoral neck fractures has high reoperation rates and some predictors of failure are known, such as age, quality of reduction, and implant positioning. Finding new predictors of failure is an ongoing process, and in this study we evaluated...... the importance of low bone mineral density (BMD). Patients and methods - 140 consecutive patients (105 females, median age 80) treated with IF had a dual-energy X-ray absorptiometry (DXA) scan of the hip performed median 80 days after treatment. The patients' radiographs were evaluated for fracture displacement......, or new hip fracture). A stratified Cox regression model on fracture displacement was applied and adjusted for age, sex, quality of reduction, implant positioning, comorbidity, and walking disability. Results - 49 patients had a T-score below -2.5 (standard deviation from the young normal reference mean...

  14. Validity of bone mineral density and WHO fracture risk assessment thresholds in hip fractures.

    Science.gov (United States)

    Shahla, Ahmad

    2011-09-01

    Hip fractures are common and serious consequence of osteoporosis. Bone mineral density (BMD) measurement and the World Health Organization (WHO) fracture risk assessment tool are considered to predict the hip osteoporotic fractures. In this study, their sensitivities in hip fracture cases are evaluated. BMD and WHO probability of fracture risk were determined in 71 hip fractures ≥ 50 years of old. Totally, 65% of patients had ≤-2.5 BMD T score. 81% of patients had above the upper interventional threshold of WHO fracture risk probability model. Sensitivities were low in 50-59 year age group with progression in older age groups. Results of BMD T score and fracture risk probabilities were not significant between men and women. There were 23% and 49% sensitivities of less than or equal to -2.5 T score in the 50-59 and 60-69 year age groups with a 31% sensitivity of greater than 3% probability of hip fracture risk in the 50-59 year age group, both of which were not valid for predicting hip fracture risk.

  15. Determinants of outcome in hip fracture patient care

    NARCIS (Netherlands)

    Vochteloo, Anne Jochem Hendrik

    2013-01-01

    In this thesis, clinical and functional outcomes of a large cohort of hip fracture patients are described, with regards to anemia, blood transfusion, concomitant fractures, loss of mobility and place of residence. Secondly, risk factors for poor outcome, both in a clinical and a functional

  16. Severe Vitamin D Deficiency in Swiss Hip Fracture Patients

    Science.gov (United States)

    Background: Based on evidence for fall and fracture prevention, most clinical guidelines for the prevention of hip fractures recommend 800 IU vitamin D per day. This dose shifted 25(OH)D levels in previous studies to between 60-100 nmol/l. Aim: As a direct test of clinical guideline practice in Swi...

  17. Evaluation of a simplified hip structure analysis method for the prediction of incident hip fracture events.

    Science.gov (United States)

    Khoo, B C C; Lewis, J R; Brown, K; Prince, R L

    2016-01-01

    Many attempts have been made to improve the predictive ability of areal bone mineral density (aBMD) which integrates bone mass and area. The addition of an extra variable derived from the hip dual-energy X-ray (DXA) image TR_σ, which describes distribution of mass within the scanned area of the trochanter, improved prediction of 15-year hip fracture probability in elderly women. Two-dimensional DXA imaging of the proximal femur to produce an aBMD is a clinically useful predictor of future fracture risk. Further analysis of the DXA image to produce an eight-variable hip structure analysis (Beck HSA) has been developed to improve understanding of structural factors determining hip bone strength at each of three proximal femur sites, the narrow femoral neck (NN), intertrochanter (TR) and shaft (S). Recently, data on four measurements derived from the currently used eight Beck HSA variables were used to capture population variation in bone structure at each site. These include two previously used variables, the localised aBMD and the sub-periosteal width (W) applying to 5-mm sections (at each sites), and two new variables, standard deviation of normalised mineral-mass projection profile distribution (σ), and displacement between centre-of-mineral mass and geometric centre-of-mineral mass of projection profile (δ). Using a cohort of 1159 women, mean baseline age 75, who sustained 139 hip fractures over 15 years, we determined whether these measures significantly improved 15-year hip fracture prediction compared to current approach utilising age and total hip aBMD. To describe the most parsimonious model for hip fracture risk prediction, the 12 base measures (4 from each site), total hip aBMD and age were evaluated in stepwise logistic regression models. The final model included TR_σ, total hip aBMD and age and provided improved utility for hip fracture prediction compared to total hip aBMD and age alone (C-statistic 0.73 vs. 0.69, P = 0.009 and net

  18. Hidden blood loss after surgery for hip fracture

    DEFF Research Database (Denmark)

    Foss, Nicolai Bang; Kehlet, H

    2006-01-01

    with aspirin, intra-operative hypotension and gastro-intestinal bleeding or ulceration were all independent predictors of blood loss. We conclude that total blood loss after surgery for hip fracture is much greater than that observed intra-operatively. Frequent post-operative measurements of haemoglobin......Our aim was to determine the total blood loss associated with surgery for fracture of the hip and to identify risk factors for increased blood loss. We prospectively studied 546 patients with hip fracture. The total blood loss was calculated on the basis of the haemoglobin difference, the number...... of transfusions and the estimated blood volume. The hidden blood loss, in excess of that observed during surgery, varied from 547 ml (screws/ pins) to 1473 ml (intramedullary hip nail and screw) and was significantly associated with medical complications and increased hospital stay. The type of surgery, treatment...

  19. Hidden blood loss after surgery for hip fracture

    DEFF Research Database (Denmark)

    Foss, N B; Kehlet, H

    2006-01-01

    Our aim was to determine the total blood loss associated with surgery for fracture of the hip and to identify risk factors for increased blood loss. We prospectively studied 546 patients with hip fracture. The total blood loss was calculated on the basis of the haemoglobin difference, the number...... of transfusions and the estimated blood volume. The hidden blood loss, in excess of that observed during surgery, varied from 547 ml (screws/ pins) to 1473 ml (intramedullary hip nail and screw) and was significantly associated with medical complications and increased hospital stay. The type of surgery, treatment...... with aspirin, intra-operative hypotension and gastro-intestinal bleeding or ulceration were all independent predictors of blood loss. We conclude that total blood loss after surgery for hip fracture is much greater than that observed intra-operatively. Frequent post-operative measurements of haemoglobin...

  20. Results of open tibial fracture treatment using external fixation

    Directory of Open Access Journals (Sweden)

    Golubović Ivan

    2016-01-01

    Full Text Available Introduction. Open lower leg fractures are the most common open fractures of the locomotor system and their treatment is associated with a number of complications. Objective. The aim of the paper was to present the results of the treatment of 68 patients with open lower leg fractures, as well as the complications that accompany the treatment of these fractures. Methods. In the analyzed group, there were 45 (66.18% men and 23 (33.82% women. The majority of patients - 33 (48.53% of them - were injured in motor vehicle accidents, whereas 24 (35.29% patients sustained injuries due to falls from heights. In two (2.94% patients the cause of open tibial fractures was gunshot injuries. In the analyzed group, there were 18 (26.47% type I open fractures, 21 (30.88% type II open fractures, 19 (27.94% type IIIA open fractures, seven (10.29% type IIIB open fractures, and three (4.41% type IIIC open fractures. Results. The tibial shaft fracture healed without serious complications in 50 (73.53% patients, whereas in 18 (26.47% patients we observed some complications. Nonunion was found in 10 (14.71% patients, osteitis in four (5.88, malunion in two (2.94% patients. Milder complications such as soft tissue pin tract infection developed in 13 (19.12% patients, infection of the open fracture wound soft tissue was observed in four (5.88% patients. Conclusion. Basic principles in the treatment of open lower leg fractures in this study are thorough primary open fracture wound treatment followed by the delayed wound closure, stable fracture fixation using unilateral external skeletal device, proper antibiotic treatment and tetanus prophylaxis. The results correlate with similar studies. [Projekat Ministarstva nauke Republike Srbije, br. III 41017: Virtual Human Osteoarticular System and its Application in Preclinical and Clinical Practice

  1. 综合康复护理对股骨粗隆间骨折行DHS内固定术患者预后的影响%Effect of comprehensive rehabilitation interventions on the patients with intertrochanteric fracture of femur treated by dynamic hip screw internal fixation

    Institute of Scientific and Technical Information of China (English)

    钟巧艺; 陈思颖; 赵洁莲; 区海云; 何惠兰

    2011-01-01

    目的:探讨综合康复护理对股骨粗隆间骨折行动力髋螺钉(dynamic hip screw,DHS)内固定术患者预后的影响.方法:选择2008年9月-2009年9月本院收治的股骨粗隆间骨折行DHS内固定术的49例患者为对照组,选择2009年10月-2010年10月收治的58例患者为实验组.对照组给予常规护理,实验组采用综合康复护理,比较两组患者骨折愈合时间、住院时间、疗效及并发症的发生率.结果:实验组骨折愈合时间及住院时间短于对照组、疗效优于对照组、并发症的发生率低于对照组(均P<0.05).结论:股骨粗隆间骨折患者行DHS内固定术后采用综合康复护理,有利于缩短骨折愈合时间及住院时间,提高治疗效果,降低术后并发症的发生率,值得临床推广应用.%Objective To explore the influence of comprehenaive rehabilitation interventions on patients with intertrochanteric fracture of femur treated by DHS (dynamic hip screw) intemal fixation. Methods Forty-nine patients with intertrochanteric fracture of femur treated by DHS intemal fixation from September 2008 to September 2009 were selected as the control group. Fifty-eight patients with intertrochanteric fracture of femur treated by DHS intemal fixation from October 2009 to October 2010 were selected as the experimental group. The control group received conventional nuraing intervention, and the experimental group received comprehensive rehabilitation nursing interventions. Healing time, hospitalization time, clinical effect and incidence of complications were compared in the two groups. Results Hospitalization time, clinical effect in the experimental group was shorter than thoae in the control group; the clinical effect was better than that in the control Sroup; the incidence of complications was lower than that in the control group. Conclusion Comprehengive nursing intervention shortens healing time and hospitalization time, increases the therapy efficacy, and decreases the

  2. In vivo implant fixation of carbon fiber-reinforced PEEK hip prostheses in an ovine model.

    Science.gov (United States)

    Nakahara, Ichiro; Takao, Masaki; Bandoh, Shunichi; Bertollo, Nicky; Walsh, William R; Sugano, Nobuhiko

    2013-03-01

    Carbon fiber-reinforced polyetheretherketone (CFR/PEEK) is theoretically suitable as a material for use in hip prostheses, offering excellent biocompatibility, mechanical properties, and the absence of metal ions. To evaluate in vivo fixation methods of CFR/PEEK hip prostheses in bone, we examined radiographic and histological results for cementless or cemented CFR/PEEK hip prostheses in an ovine model with implantation up to 52 weeks. CFR/PEEK cups and stems with rough-textured surfaces plus hydroxyapatite (HA) coatings for cementless fixation and CFR/PEEK cups and stems without HA coating for cement fixation were manufactured based on ovine computed tomography (CT) data. Unilateral total hip arthroplasty was performed using cementless or cemented CFR/PEEK hip prostheses. Five cementless cups and stems and six cemented cups and stems were evaluated. On the femoral side, all cementless stems demonstrated bony ongrowth fixation and all cemented stems demonstrated stable fixation without any gaps at both the bone-cement and cement-stem interfaces. All cementless cases and four of the six cemented cases showed minimal stress shielding. On the acetabular side, two of the five cementless cups demonstrated bony ongrowth fixation. Our results suggest that both cementless and cemented CFR/PEEK stems work well for fixation. Cup fixation may be difficult for both cementless and cemented types in this ovine model, but bone ongrowth fixation on the cup was first seen in two cementless cases. Cementless fixation can be achieved using HA-coated CFR/PEEK implants, even under load-bearing conditions.

  3. Intermaxillary Fixation Screw Morbidity in Treatment of Mandibular Fractures

    DEFF Research Database (Denmark)

    Florescu, Vlad-Andrei; Kofod, Thomas; Pinholt, Else Marie

    2016-01-01

    Surgery, Rigshospitalet, University Hospital of Copenhagen, Copenhagen, Denmark). The fracture type, radiographic findings, treatment modality, screw type and number, and root damage were recorded. For the outcome comparison, a review of the published data regarding iatrogenic dental root damage caused......Purpose The aim of the present retrospective study was to investigate the morbidity of screws used for intermaxillary fixation (IMF) in the treatment of mandibular fractures. A review of the published data was also performed for a comparison of outcomes. Our hypothesis was that the use of screws...... for IMF of mandibular fractures would result in minimal morbidity. Materials and Methods Patients treated for mandibular fractures from 2007 to 2013, using screws for IMF, using the international diagnosis code for mandibular fracture, DS026, were anonymously selected (Department of Oral and Maxillofacial...

  4. Hip dislocation following the treatment of femoral neck fracture: Case report

    Directory of Open Access Journals (Sweden)

    Vukašinović Zoran

    2010-01-01

    Full Text Available Introduction. Femoral neck fractures are very rare in young patients and are frequently complicated by femoral head osteonecrosis and femoral neck nonunion. Case Outline. A 19-year-old girl with hip dislocation following the treatment of the femoral neck fracture is presented. The femoral neck fracture was initially treated by open reduction and three-screw fixation. After detecting the nonunion of femoral neck, valgus osteotomy was done. Secondary, iatrogenic, hip dislocation appeared. The patient had pains, and in clinical findings a shorter leg and limited range of motion in the hip - altogether 40 degrees. She was then successfully treated by open reduction, together with Chiari pelvic osteotomy and joint transfixation. Transfixation pin was removed three weeks following the operation. After that, the patient was put into the abduction device and physical therapy was started. The mentioned regimen lasted four months after the surgery, then the abduction device was removed and walking started. Full weight bearing was allowed eight months after surgery. Conclusion. As we have not found the literature data concerning the above mentioned problem, we solved it in the way that we usually do for the treatment of developmental dislocation of the hip in adolescence.

  5. The risk of major and any (non-hip) fragility fracture after hip fracture in the United Kingdom : 2000-2010

    NARCIS (Netherlands)

    Gibson-Smith, D; Klop, C; Elders, P J M; Welsing, P M J; van Schoor, N; Leufkens, H G M; Harvey, N C; van Staa, T P; de Vries, F

    2014-01-01

    UNLABELLED: The risk of a subsequent major or any fracture after a hip fracture and secular trends herein were examined. Within 1 year, 2.7 and 8.4% of patients sustained a major or any (non-hip) fracture, which increased to 14.7 and 32.5% after 5 years. Subsequent fracture rates increased during th

  6. The risk of major and any (non-hip) fragility fracture after hip fracture in the United Kingdom : 2000-2010

    NARCIS (Netherlands)

    Gibson-Smith, D; Klop, C; Elders, P J M; Welsing, P M J; van Schoor, N; Leufkens, H G M; Harvey, N C; van Staa, T P; de Vries, F

    UNLABELLED: The risk of a subsequent major or any fracture after a hip fracture and secular trends herein were examined. Within 1 year, 2.7 and 8.4% of patients sustained a major or any (non-hip) fracture, which increased to 14.7 and 32.5% after 5 years. Subsequent fracture rates increased during

  7. Internal fixation of mandibular angle fractures: a meta-analysis.

    Science.gov (United States)

    Regev, Eran; Shiff, Jacob S; Kiss, Alex; Fialkov, Jeffrey A

    2010-06-01

    The degree of rigidity of internal fixation required for the treatment of mandibular angle fractures has long been at the center of debate in the literature. A statistical comparison between rigid fixation and monocortical fixation has been difficult because of multiple terms, definitions, and technical variations. The purpose of this study was to use the meta-analysis tool to combine information from multiple studies and to compare complication rates for different fixation methods. An English language literature search was conducted for articles on mandibular angle fractures. Information was collected on four variables of interest: compression/noncompression technique, monocortical/bicortical screws, number of plates, and location of plates. Five outcome rates were analyzed: infection, reoperation, hardware removal, malunion, and nonunion. Meta-analyses were run using Comprehensive Meta Analysis, version 2.2.03. Twenty-four studies with relevant data on the variables and outcomes of interest met the inclusion criteria. Significantly higher rates of infection, reoperation, and hardware removal were found for compression compared with noncompression, two plates compared with one plate, and for plates located on both the inferior and superior borders as compared with superior or inferior only. There were also significantly higher infection rates for bicortical screws compared with monocortical screws and higher malunion rates for compression compared with noncompression plating techniques. The results of this meta-analysis found lower complication rates with the use of noncompression, monocortical, and single-plate fixation, supporting the trend toward a single, superiorly placed, monocortical miniplate for fixation of mandibular angle fractures.

  8. Biomechanical evaluation of maxillary Lefort Ι fracture with bioabsorbable osteosynthesis internal fixation.

    Science.gov (United States)

    Wu, Wei; Zhou, Jiang; Xu, Chong-Tao; Zhang, Jie; Jin, Yan-Jiao; Sun, Geng-Lin

    2014-12-01

    The aim of this study was to apply biomechanical analysis model to evaluate the effects of bioabsorbable internal fixation devices on maxillary Lefort Ι fracture. CT scan technology and the finite element software (ansys) were used to establish three-dimensional finite element models of five resorbable internal fixation devices in maxillary Lefort Ι fractures. We used the model to calculate the stress of the upper jaw and internal fixation. We further analyzed the stability of fixation under four occlusions. The fixation using two bioabsorbable plates was not stable. The zygomaticomaxillary pillars fixation is more stable than other fixations. The stability of fracture fixation was influenced with the molar occlusion. The current study developed a functional three-dimensional finite element model of bioabsorbable internal fixation and compared the stability of five fixation methods for maxillary Lefort Ι fractures. The results would facilitate the application of bioabsorbable materials in dental clinic.

  9. Feasibility and Value of Radiographic Union Score Hip Fracture after Treatment with Intramedullary Nail of Stable Hip Fractures

    Science.gov (United States)

    Maiettini, Daniele; Bisaccia, Michele; Caraffa, Auro; Rinonapoli, Giuseppe; Piscitelli, Luigi; Bisaccia, Olga; Rollo, Giuseppe; Meccariello, Luigi; Ceccarini, Paolo; Rebonato, Alberto

    2016-01-01

    Introduction: Given the importance of fracture healing on patient outcome in clinical practice, it is critical to assess fracture healing. Aim: The aim of this study was to evaluate the feasibility of the Radiographic Union Score Hip fracture after treatment with intramedullary nail of stable hip fractures. Patients and Methods: We retrospectively collected the data from the clinical records of our institution of the 47 patientswho had undergone intertrochanteric hip fracture treatment using an intramedullary nail. Pain visual analogic score (VAS) was collected the same day that X-rays were taken. Plain hip X-rays were performed, in two radiographic views, at 40 and 90 days after the surgical procedure. The correlation between the RUSH and VAS score was evaluated. Results: Mean RUSH and VAS scores showed a strong statistical improvement between the 40 and 90 day follow-ups. RUSH value at 40 days fitted an inverse linear regression with VAS, p-value of 0.0063 and r2 of 0.15. At 90 days the regression between RUSH and VAS scores was not significant. Conclusion: RUSH could be proposed as an objective system to evaluate union in hip fractures treated with intramedullary nail. PMID:28077901

  10. Patient characteristics and outcomes of a hip fracture and concomitant fracture compared with hip fracture alone: results from a United Kingdom teaching hospital.

    Science.gov (United States)

    Ong, Terence; Anand, Varun; Tan, Wei; Quah, Edmund; Moran, Chris; Sahota, Opinder

    2016-04-01

    A proportion of patients sustaining hip fractures present with a concomitant fracture. We aimed to evaluate the relationship between patient characteristics and clinical outcomes, in those with a hip and concomitant fracture compared with those sustaining a hip fracture alone from a clinical service registry. Cross-sectional study using data obtained from a clinical service registry (Nottingham Hip Fracture Database) on patients aged 50 and above who suffered a hip fracture between 1/1/2003 and 31/12/2012. Data was collected on patient demographics, fracture information and healthcare outcomes. 7338 patients of which 75 % were female (mean age 82 (SD 9.4), had a hip fracture with 334 (4.6 %) patients having a concomitant fracture. The majority (58 %) were distal radius or proximal humeral fractures. Only females (p = 0.002), those taking three or fewer medications (p = 0.018) and those on long term steroids (p = 0.048) were more likely to suffer a concomitant fracture. There was no difference in mortality, rates of postoperative complication, intensive care unit or care home admission between both groups. Patients with a concomitant fracture have a 16 % longer average length of stay in hospital (mean difference 1.16; 95 % CI 1.07-1.25, p fractures have similar patient characteristics, except gender, polypharmacy and long term steroid use; and outcomes to those presenting with hip fracture alone, except a longer average inpatient stay.

  11. FUNCTIONAL OUTCOME OF PHILOS PLATE FIXATION FOR PROXIMAL HUMERUS FRACTURES

    Directory of Open Access Journals (Sweden)

    Ch. Venkateswarlu

    2016-01-01

    Full Text Available INTRODUCTION Treating a proximal humerus fracture remained a challenging problem until proximal humeral internal locking system has been developed. Our study aims at evaluating the functional outcome of 30 consecutive patients with proximal humeral fracture treated by Philos plate fixation; 30 patients with proximal humeral fractures who attended our hospital between December 2013 and December 2015 were included in the study; 18 women and 12 men with a mean age of 47.5years (30-60 years are included. Data was collected prospectively and outcomes were assessed using constant shoulder score. The mean follow-up period was 12 months (6-18 months. Mean union time of all the fractures was 11.4 weeks (8-20 weeks. The mean constant shoulder score at final review was 70.5 (52-92. Philos plate provides stable fracture fixation for proximal humerus fracture in both young and elderly patients, which enables for early mobilisation and achieves acceptable functional results.

  12. [Implant materials for the internal fixation of midfacial fractures].

    Science.gov (United States)

    Stuck, B A; Heller, T

    2011-11-01

    The material used for osteosynthesis plays a crucial role in the management of facial fractures. Plates need to be flexible enough to be bent and should not be palpable through the skin, while ensuring stable fixation und adequate biocompatibility. Although stainless steel was initially the material of choice, titanium has become the standard material due to its superior biocompatibility. While the explantation of titanium plates and screws appears unnecessary in general, it should be considered in cases of dislocation, cosmetic concerns, pain and infection. Due to their limited initial stability and a potential increase in local complications, resorbable materials based on polymeric lactose are used with caution in midfacial fractures in adults. Our own retrospective study comparing the postoperative complications after fixation of lateral midfacial fractures with titanium and resorbable systems demonstrated a low complication rate for both systems (7-8%) and no statistically significant difference between the two. The appropriate material for fixation should be selected based on the localization and severity of the fracture, the experience of the surgeon as well as on the age and overall condition of the patient.

  13. Risk Factors for Hip Fracture in Japanese Older Adults

    Directory of Open Access Journals (Sweden)

    Takashi Yamashita

    2012-09-01

    Full Text Available Risk factors for hip fracture in Japanese older populations are understudied compared with Western countries arguably due to the relatively lower prevalence rates in Japan. Nationally representative data from the Nihon University Japanese Longitudinal Study of Aging were analyzed using logistic regression to examine possible risk factors of hip fractures, separately for older women (n = 2,859 and older men (n = 2,108. Results showed that older Japanese women with difficulty bending their knees (OR = 1.9, with diabetes (OR = 1.7 times, and/or with more activity of daily living limitations (OR = 1.1 had higher risks of hip fracture. Older Japanese men with difficulty bending their knees (OR = 2.6, who use more external prescription drugs (OR = 1.9, and with cancer (OR = 2.0 times had higher risks of hip fracture. Further considerations of gender- and culture-specific factors along with the identified risk factors may provide insights into future intervention programs for hip fracture in Japanese older populations.

  14. Total hip arthroplasty vs. osteosynthesis in acute complex acetabular fractures in the elderly: Evaluation of surgical management and outcomes

    Directory of Open Access Journals (Sweden)

    Serafino Carta

    2017-01-01

    Full Text Available Objective: To retrospectively evaluate the open reduction internal fixation and total hip arthroplasty directions, results and complications associated with internal fixation in managing these fractures. Methods: In 8 years at 4 centers, 61 patients with associated acetabular fractures (Letournel classification were treated. The patients were divided into two groups. The total hip arthoplasty (THA group consisted of 30 patients, while the open reduction internal fixation group had 31 patients. The average age of the patients was 74.7 years. The following parameters were compared: the duration of surgery and hospitalization, the international unit of red blood cell concentrate transfusion, the time for the verticalization of the patient, perioperative complications, Harris hip score, and the short form (12 health survey. The clinical and radiographic follow-up was performed at 1 month, 3 months, 6 months and 12 months and annually thereafter. Patients with post-traumatic osteoarthritis formed the third comparison group. P ≤ 0.05 was considered statistically significant according to the analytical Student’s t-test. Results: The P < 0.05 in favor of the THA group was: surgical time, length of stay, number of the international unit of red blood cell concentrate transfusions, verticalization, quality of life and hip function, a reduction of perioperative complications and reinterventions. Conclusions: Our experience shows that the THA treatment for acetabular fractures in the elderly is to be preferred.

  15. Early Definitive Fixation of an Open Periprosthetic Femur Fracture in the Polytraumatized Patient: A Case Report and Review of the Literature.

    Science.gov (United States)

    Aleem, Ilyas S; Bhandari, Mohit; Elizalde, Sebastian Rodriguez

    2016-01-01

    Periprosthetic fractures of the femur after total hip arthroplasty are increasing in frequency. In the polytraumatized patient with long-bone fracture, an ongoing debate exists regarding early definitive stabilization versus initial damage control orthopaedics, followed by delayed fixation. It remains to be seen whether this rationale applies to the polytraumatized patient with periprosthetic fracture. We present the case of a 73-years old Caucasian woman who sustained bilateral Gustillo-Anderson grade III open femur fractures; the fracture on the right was a Vancouver C open periprosthetic fracture after cemented total hip arthroplasty. After massive fluid resuscitation in the trauma bay she was taken to the intensive care unit in a hemodynamically unstable condition. She was subsequently operated and underwent early definitive fixation of both femurs with the rationale of potentially reducing pulmonary complications and promoting early mobilization. Early definitive stabilization versus delayed fixation in the polytraumatized patient with an open periprosthetic femur fracture is reviewed. Although several treatment algorithms based on fracture classification and implant stability exist, further study is required to delineate the preferred method and timeline of fixation for this growing cohort of patients.

  16. High mortality and poor morbidity after hip fracture in patients with previous vertebral fractures.

    Science.gov (United States)

    Ha, Yong-Chan; Baek, Ji-Hoon; Ko, Young-Bong; Park, Sang-Min; Song, Sang-Heon

    2015-09-01

    Although vertebral fracture in patients is a predictor of subsequent hip fracture, no study has assessed the mortality and functional outcome in hip fracture patients with previous vertebral fracture. Between September 2009 and December 2012, we evaluated 246 patients over 50-years-of-age diagnosed with femoral neck or intertrochanteric fractures who underwent surgery. The patients were categorized into two groups and two subgroups. Group Ia comprised 150 patients with previous vertebral fracture at the time of hip fracture. Group Ib comprised 96 patients with no vertebral fracture. Group IIa consisted of 76 patients fracture. Group IIb comprised 69 patients fracture. The mortality rate and functional outcome of osteoporotic hip fracture patients with and without vertebral fractures were compared. The cumulative mortality rate at 6 and 12 months post-fracture was 19 and 23 % in Group Ia and 6 and 7 % in Group Ib, respectively. In subgroup analysis, the cumulative mortality rate at 6 and 12 months was 13 and 17 % in Group IIa and 3 and 4 % in Group IIb, respectively. Shut-in patients at the final follow-up included 51 of 103 (49.5 %) patients in Group Ia and 19 of 83 (22.9 %) patients in Group Ib. In subgroup analysis, the shut-in patients included 18 of 58 (31.0 %) patients in Group IIa and 10 of 62 (16.1 %) patients in Group IIb. Previous vertebral fracture was associated with a poor functional outcome and increased mortality in patients with hip fracture.

  17. Internal fixation and muscle pedicle bone grafting in femoral neck fractures

    Directory of Open Access Journals (Sweden)

    Gupta A

    2008-01-01

    Full Text Available Background: The treatment of displaced intracapsular femoral neck fracture is still an unsolved problem. Non-union and avascular necrosis are the two main complications of this fracture, especially if patient presents late. Muscle pedicle bone grafting has been advocated to provide additional blood supply. We present analysis of our 32 cases of displaced femoral neck fracture treated by internal fixation and quadratus femoris based muscle pedicle bone grafting. Materials and Methods: Open reduction and internal fixation with muscle pedicle grafting was done in 32 patients. The age of patients varied from 14-62 years (average age 45 years with male to female ratio of 13:3. Twenty-nine fractures were more than three weeks old. All the cases were treated by Meyers′ procedure. The fracture was internally fixed after open reduction and then a muscle pedicle graft was applied. It was supplemented by cancellous bone graft in seven cases. Fixation was done by parallel cancellous lag screws ( n = 19, crossed Garden′s screws ( n = 7, parallel Asnis screws ( n = 5 and Moore′s pin ( n = 1.Quadratus femoris muscle pedicle graft was used in 32 cases. In the initial 12 cases the graft was fixed with circumferential proline sutures, but later, to provide a secure fixation, the graft was fixed with a cancellous screw ( n = 20. Postoperative full weight bearing was deferred to an average of 10 weeks. Results: Union was achieved in 26/29 (89.65% cases which could be followed for an average period of 3.4 years, (2-8.5 years with good functional results and had the ability to squat and sit cross-legged. Results were based on hip rating system given by Salvatti and Wilson. The results were excellent in 15 cases, good in four cases, fair in four cases and poor in six cases. Complications were avascular necrosis ( n = 2, transient foot drop ( n = 2, coxa-vara ( n = 1 and temporary loss of scrotal sensation ( n = 1. Conclusion: Muscle pedicle bone grafting with

  18. A simple technique to position patients with bilateral above-knee amputations for operative fixation of intertrochanteric fractures of the femur: a case report

    Directory of Open Access Journals (Sweden)

    Dramis Asterios

    2010-11-01

    Full Text Available Abstract Introduction Intertrochanteric fractures of the femur are common fractures in the elderly, and management includes operative fixation after patient positioning on the fracture table. Patients with bilateral above-knee amputations are challenging in terms of positioning on the table. We describe a simple technique to overcome this special problem. Case presentation A 75-year-old wheelchair-bound Caucasian man with bilateral above-knee amputations presented to our hospital after a fall. Plain radiographs showed an intertrochanteric fracture of the femur, and operative fixation with a dynamic hip screw was planned. His positioning on the table posed a particular problem, and therefore we developed a technique to overcome this problem. Conclusion Positioning of patients for fixation of intertrochanteric fractures of the femur poses a particular problem that can be solved by using our simple technique.

  19. External Fixation of Unstable Distal Radius Fracture. A Case Report

    Directory of Open Access Journals (Sweden)

    Yaniel Truffin Rodríguez

    2014-12-01

    Full Text Available Unstable fracture of the distal radius is a common injury. If not properly treated, it can cause major disturbance in the radiocarpal joint and impaired hand function. A case of a 42-year-old patient of rural origin without a history of previous conditions treated at the Gustavo Aldereguía Lima Hospital in Cienfuegos is presented. He suffered a fall on the outstretched hand, which led to an unstable fracture of the left distal radius. Emergency surgery consisting of manual fracture reduction under general anesthesia and fixation with RALCA minifixator plus a percutaneously placed Kirschner wire was performed. Since this fracture is often inadequately treated, the presentation of this case can be helpful to many orthopedic surgeons.

  20. Short Segment Fixation Versus Short Segment Fixation With Pedicle Screws at the Fracture Level for Thoracolumbar Burst Fracture

    Directory of Open Access Journals (Sweden)

    Anghel S

    2014-04-01

    Full Text Available Objective: The most prevailing surgical procedure in the treatment of thoracolumbar burst fractures, Short Segment Fixation (SSF, is often followed by loss of correction or hardware failure which may be significant enough to require another surgical intervention. In order to take advantage of its benefits but to avoid or diminish the risk and impact of associated drawbacks, some other alternatives have been lately developed among which we refer to short segment fixation with intermediate screws (SSF+IS. This article provides a comparative picture over the effectiveness of the two above-mentioned surgical treatments, focusing on their potential to prevent the loss of correction.

  1. Medical Cost Analysis of the Osteoporotic Hip Fractures

    Directory of Open Access Journals (Sweden)

    Savaş Çamur

    2015-12-01

    Full Text Available Objective: Osteoporotic hip fractures decrease the life expectancy for 20% about 20-50% of the patients become permanently dependent in terms of walking for the rest of their life. Life expectancy is increasing in Turkey in the last 20 years. We investigated the impact of osteoporotic hip fractures which increase the morbidity and mortality on the national economy. Materials and Methods: A total of 81 patients admitted to our emergency department with the diagnosis of femur intertrochanteric fracture and femoral neck fracture between 2008 and 2012 were included in this study. We retrospectively evaluated the medical records and the medical costs of these patients from hospital information management system. Results: Of the 81 patients 32 (39.6% males and 49 (60.4% females meeting the inclusion criteria were included in this study. The mean age was 80.1 years (range, 61-103. Twenty-three (27.5% patients had femoral neck fracture and 58 (72.5% patients had intertrochanteric femur fracture. The mean length of hospital stay was 13.4 days in intertrochanteric femur fracture and 15.5 days in femoral neck fracture; average of the total days of hospitalization of all patients was 13.9 days. The average treatment cost per patient was 5,912.36 TL for intertrochanteric fractures, 5,753.00 TL for neck fractures, and 5,863.09 TL for the whole patient population. Conclusion: Hip fracture is a substantial cause of morbidity and mortality in elderly. Taking preventive measures before the fracture occurs may help to prevent this problem which has a high cost treatment and which is a substantial burden for the national economy.

  2. A Prospective Randomized Trial to Assess Fixation Strategies for Severe Open Tibia Fractures: Modern Ring External Fixators Versus Internal Fixation (FIXIT Study).

    Science.gov (United States)

    OʼToole, Robert V; Gary, Joshua L; Reider, Lisa; Bosse, Michael J; Gordon, Wade T; Hutson, James; Quinnan, Stephen M; Castillo, Renan C; Scharfstein, Daniel O; MacKenzie, Ellen J

    2017-04-01

    The treatment of high-energy open tibia fractures is challenging in both the military and civilian environments. Treatment with modern ring external fixation may reduce complications common in these patients. However, no study has rigorously compared outcomes of modern ring external fixation with commonly used internal fixation approaches. The FIXIT study is a prospective, multicenter randomized trial comparing 1-year outcomes after treatment of severe open tibial shaft fractures with modern external ring fixation versus internal fixation among men and women of ages 18-64. The primary outcome is rehospitalization for major limb complications. Secondary outcomes include infection, fracture healing, limb function, and patient-reported outcomes including physical function and pain. One-year treatment costs and patient satisfaction will be compared between the 2 groups, and the percentage of Gustilo IIIB fractures that can be salvaged without soft tissue flap among patients receiving external fixation will be estimated.

  3. Anaemia impedes functional mobility after hip fracture surgery

    DEFF Research Database (Denmark)

    Foss, N.B.; Kristensen, M.T.; Kehlet, H.

    2008-01-01

    BACKGROUND: the impact of anaemia on the outcome after a hip fracture surgery is controversial, but anaemia can potentially decrease the physical performance and thereby impede post-operative rehabilitation. We therefore conducted a prospective study to establish whether anaemia affected functional...... mobility in the early post-operative phase after a hip fracture surgery. PATIENTS AND METHODS: four hundred and eighty seven consecutive hip fracture patients, treated according to a well-defined multimodal rehabilitation programme with a uniform, liberal transfusion threshold, were studied. Hb...... integrating the type of surgery, medical complications and prefracture function showed that anaemia at the time of the physiotherapy session was an independent risk factor for not being able to walk on the third post-operative day [OR 0.41 (0.14-0.73) P = 0.002]. CONCLUSION: anaemia impedes functional...

  4. Surgical technique for minimally invasive fibula fracture fixation.

    Science.gov (United States)

    Carlile, G S; Giles, N C L

    2011-09-01

    This paper describes a minimally invasive percutaneous technique for reduction and fixation of distal fibula fractures using plate osteosynthesis. We believe this technique benefits patients with poor quality soft tissue envelopes. So far a total of 25 patients have undergone percutaneous fixation, 22 females and 3 males. At no stage yet has a minimally invasive procedure been abandoned intra-operatively in favour of conversion to an open procedure. The mean age was 61.6 years (range 25-80 years). The mean time to surgery was 2.00 days (range 0-5) and mean time to discharge was 4.20 days (range 1-9). At a minimum of over 1 year's follow-up all fractures have healed, with no delayed unions or complications so far experienced.

  5. RESORBABLE HIGH-STRENGTH ROD FOR FRACTURE INTERNAL FIXATION

    Institute of Scientific and Technical Information of China (English)

    杨团民; 刘淼; 杨爱玲; 石宗利; 邱希江; 李毅; 同志超; 韩月

    2004-01-01

    Objective To find an ideal biomaterial for internal fixation. Methods Forty rabbits with fracture of the femur diaphysis (superiorcondyle) were treated by intramedullary nailing of femur with composites rod of resorbable DL-polylactic acid (PDLLA)-calcium metaphosphate (CMP), while steinmann's pin as control. The fracture healing, the material degradation and its mechanical properties were studied by X-ray films, macroscopic, microscopic and electron microscopic observations. Results No significant inflammatory reaction was found, and all the osteotomies were healed, while material was resorbed. Conclusion The PDLLA-CMP has excellent biocompatibility and mechanical properties, and it can be a promising implant material in orthopaedics surgery.

  6. Internal Fixation of Open Ankle Fracture. Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Yaniel Truffin Rodríguez

    2014-10-01

    Full Text Available Open ankle fracture is sporadically seen in the orthopedic practice. Its clinical course is subject to multiple factors, showing a propensity to cause ankle osteoarthritis over the years. Two cases treated at the Dr. Gustavo Aldereguía Lima University General Hospital in Cienfuegos are presented. The patients underwent emergency surgical treatment consisting of surgical cleaning of the open wound, reduction of the dislocation and internal fixation of the fracture. These cases are presented due to the infrequency of this type of ankle injury and its importance for the medical staff, especially orthopedic doctors.

  7. Virtual-reality simulation to assess performance in hip fracture surgery

    DEFF Research Database (Denmark)

    Pedersen, Poul; Palm, Henrik; Ringsted, Charlotte

    2014-01-01

    BACKGROUND AND PURPOSE: Internal fixation of hip fractures is a common and important procedure that orthopedic surgeons must master early in their career. Virtual-reality training could improve initial skills, and a simulation-based test would make it possible to ensure basic competency of junior...... experienced surgeon failing the test. INTERPRETATION: The simulation-based test was reliable and valid in our setting, and the pass/fail standard could discriminate between novices and experienced surgeons. Potentially, training and testing of future junior surgeons on a virtual-reality simulator could ensure...

  8. Complications of total hip arthroplasty: periprosthetic fractures of the acetabulum.

    Science.gov (United States)

    Chitre, Amol; Wynn Jones, Henry; Shah, Nikhil; Clayson, Anthony

    2013-12-01

    Periprosthetic fractures of the acetabulum are a rare but potentially disastrous complication of total hip arthroplasty. Such fractures occur either as early perioperative complications or late complications when they are associated with either significant trauma or as a result of the loss of the structural integrity of the bone supporting the prosthesis, such as aseptic osteolysis. The incidence of such fractures appears to be increasing with the increased use of uncemented acetabular components. This article explores the current literature on the epidemiology, etiology, and classification of periprosthetic acetabular fractures as well as offering potential treatment strategies.

  9. Internal fixations of proximal femoral nail antirotation versus that of dynamic hip screw for femoral intertrochanteric fracture%抗旋转型股骨近端髓内钉内固定与动力髋螺钉内固定治疗股骨转子间骨折的临床疗效对比观察

    Institute of Scientific and Technical Information of China (English)

    梁荣班; 赵佳; 卢珂恩; 谭宏昌

    2014-01-01

    Objective To explore and study the clinical effects of the internal fixations of proximal femoral nail antirotation(PFNA) and dynamic hip screw(DHS) for femoral intertrochanteric fracture.Methods 100 patients with femoral intertrochanteric fracture admitted into our hospital from April,2009 to April,2013 were selected as study objects and randomly and equally divided into two groups.50 patients (PFNA group) were treated by the internal fixation of PFNA,and the other 50 patients (DHS group) by the internal fixation of DHS.They were followed up for 9-18 months.The curative effects of both groups were observed and compared.Results The volumes of intraoperative bleeding and of the postoperative drainage were smaller and the postoperative weight-loading walking time and healing time were shorter in the PFNA group than in the DHS group.The Harris hip function scores were increased in both groups after the treatment; the hip function scores,motion ranges,and synthetic scores were increased more but the hip joint score of deformity less in the PFNA group than in the DHS group.The incidence of postoperative complications of the PFNA group was 6.0%,which was significantly lower than that of the DHS group (26.0%),with a statistical difference (P<0.05).Conclusions PFNA has better curative effects than DHS in the treatment of femoral intertrochanteric fracture and has greater comparative advantages in intraoperative bleeding volume,postoperative healing time,and weight-bearing walking time.Comparing with DHS treatment,PENA treatment causes fewer postoperative complications and recovers hip joint function better,so it can be the first treatment choice for patients with femoral intertrochanteric fracture.%目的 探究抗旋转型股骨近端髓内钉(PFNA)内固定与动力髋螺钉(DHS)内固定在股骨转子间骨折中的临床疗效.方法 选取自2009年4月至2013年4月我院收治的股骨转子间骨折患者100例,将其作为研究对

  10. Survival and Functional Outcomes after Hip Fracture among Nursing Home Residents

    National Research Council Canada - National Science Library

    Cho, Hong Man; Lee, Kyujung; Min, Woongbae; Choi, Yong Suk; Lee, Hyun Suk; Mun, Hyoung Jin; Shim, Hye Young; Lee, Da Geon; Yoo, Mi Joung

    2016-01-01

    .... Despite the fact that this is a high-risk group vulnerable to hip fractures, no study has yet been conducted in Korea on hip fracture incidence rates and prognoses among patients residing at nursing homes...

  11. Complications and institutionalization are almost doubled after second hip fracture surgery in the elderly patient

    NARCIS (Netherlands)

    T.J. van der Steenhoven; B. Staffhorst (Bas); S.K. van de Velde (Samuel); R.G.H.H. Nelissen (Rob); M.H.J. Verhofstad (Michiel)

    2015-01-01

    markdownabstractAbstract Purpose To determine patient and hip fracture characteristics, early postoperative complication rate and need for institutionalization at time of discharge from the hospital in patients treated for a second, contralateral hip fracture. Methods During a

  12. Economic evaluation of osteoporosis liaison service for secondary fracture prevention in postmenopausal osteoporosis patients with previous hip fracture in Japan.

    Science.gov (United States)

    Moriwaki, K; Noto, S

    2017-02-01

    A model-based cost-effectiveness analysis was performed to evaluate the cost-effectiveness of secondary fracture prevention by osteoporosis liaison service (OLS) relative to no therapy in patients with osteoporosis and a history of hip fracture. Secondary fracture prevention by OLS is cost-effective in Japanese women with osteoporosis who have suffered a hip fracture.

  13. Outcome after osteosynthesis of hip fractures in nonagenarians

    Directory of Open Access Journals (Sweden)

    de Leur K

    2013-12-01

    Full Text Available Kevin de Leur,1 Jos P A M Vroemen,1 Dagmar I Vos,1 Leon Elmans,2 Lijckle van der Laan1 1Department of Surgery, 2Orthopedics, Amphia Hospital, Breda, The Netherlands Background: Hip fractures in the elderly population are associated with high morbidity and mortality. However, there is still a lack of information on mortality and loss of independence in extremely elderly people with a hip fracture. Objective: To study functional outcomes and mortality after osteosynthesis of hip fractures in very old patients in our clinic. Patients and methods: Hospital charts of all patients over 90 years old who were operated for a hip fracture between January 2007 and December 2011 were reviewed. Outcome measures were mortality, preoperative and postoperative mobility, and loss of independence. Results: A total of 149 patients were included; 132 (89% women, median age 93.5±2.45 years. Thirty-six (24% patients were classified as American Society of Anesthesiologists (ASA grade 2, 104 (70% as ASA grade 3, and nine (6% as ASA grade 4. The Charlson comorbidity index (CCI score was 2 or less in 115 (77% patients and 34 (23% patients scored 3 or more points. Short-term survival was 91% and 77% at 30 days and 3 months, respectively. Long-term survival was 64%, 42%, and 18% at 1, 3, and 5 years after surgery, respectively. Survival was significantly better in patients with lower ASA scores (P=0.005. No significant difference in survival was measured between patients according to CCI score (P=0.13. Fifty-one percent of patients had to be accommodated in an institution with more care following treatment, and 57% were less mobile after osteosynthesis of a hip fracture. Conclusion: Our study shows that short-term mortality rates in very elderly patients with a hip fracture are high and there is no clear predictive value for mortality. ASA classification is the best predictive value for overall mortality. A large proportion of these patients lost their independence after

  14. A comprehensive hip fracture program reduces complication rates and mortality

    DEFF Research Database (Denmark)

    Pedersen, Susanne Juhl; Moltke, Finn Borgbjerg; Schousboe, B.

    2008-01-01

    OBJECTIVES: To evaluate the rate of postoperative complications, length of stay, and 1-year mortality before and after introduction of a comprehensive Multidisciplinary fast-track treatment and care program for hip fracture patients (the optimized program). DESIGN: Retrospective chart review...... with historical control. SETTING: Orthopedic ward (110 beds) at a university hospital (700 beds). PARTICIPANTS: Five hundred thirty-five consecutive patients aged 40 and older (94% >= 60) hospitalized for hip fracture between January 1, 2003, and March 3 1, 2004. Three hundred and thirty-six patients (70.3%) were...... tract infection (P mortality was 23% in the control group versus 12% in the intervention...

  15. Retrospective comparison of percutaneous fixation and volar internal fixation of distal radius fractures.

    Science.gov (United States)

    Lozano-Calderón, Santiago A; Doornberg, Job N; Ring, David

    2008-06-01

    A change in the practice of a single surgeon provided an opportunity for retrospective comparison of comparable cohorts treated with percutaneous fixation (17 patients) or a volar plate and screws (23 patients) an average of 30 months after surgery. The final evaluation was performed according to the Gartland and Werley and Mayo rating systems and the DASH questionnaire. There were no significant differences on the average scores for the percutaneous and volar plating groups, respectively: Gartland and Werley, 4 vs 5; Mayo, 82 vs 83; and DASH score 13 for both cohorts. Motion, grip, and radiographical parameters were likewise comparable. Volar internal plate and screw fixation can achieve results comparable to percutaneous fixation techniques in the treatment of fractures of the distal radius.

  16. Fixation of displaced subcapital femoral fractures. Compression screw fixation versus double divergent pins.

    Science.gov (United States)

    Christie, J; Howie, C R; Armour, P C

    1988-03-01

    One hundred and twenty-seven consecutive patients with displaced subcapital fractures of the femoral neck (Garden Grade III or IV) all under 80 years of age and independently mobile, were randomly allocated to fixation with either double divergent pins or a single sliding screw-plate device. The incidence of non-union and infection in the sliding screw-plate group was significantly higher, and we believe that when internal fixation is considered appropriate multiple pinning should be used. Mobility after treatment was disappointing in about half of the patients, and we feel that internal fixation can only be justified in patients who are physiologically well preserved and who maintain a high level of activity.

  17. Survival of ceramic bearings in total hip replacement after high-energy trauma and periprosthetic acetabular fracture.

    Science.gov (United States)

    Salih, S; Currall, V A; Ward, A J; Chesser, T J S

    2009-11-01

    Surgeons remain concerned that ceramic hip prostheses may fail catastrophically if either the head or the liner is fractured. We report two patients, each with a ceramic-on-ceramic total hip replacement who sustained high-energy trauma sufficient to cause a displaced periprosthetic acetabular fracture in whom the ceramic bearings survived intact. Simultaneous fixation of the acetabular fracture, revision of the cementless acetabular prosthesis and exchange of the ceramic bearings were performed successfully in both patients. Improved methods of manufacture of new types of alumina ceramic with a smaller grain size, and lower porosity, have produced much stronger bearings. Whether patients should be advised to restrict high-impact activities in order to protect these modern ceramic bearings from fracture remains controversial.

  18. Total hip arthroplasty with cementless cup after acetabular fracture

    Directory of Open Access Journals (Sweden)

    Marcelo Alfonso Lugones

    2012-12-01

    Full Text Available Background Acetabular fractures are a common cause of degenerative hip arthritis. The incidence of post-traumatic osteoarthritis has been reported between 12% and 57% and avascular necrosis of the femoral head may occur in 2% to 40% after posterior fracture dislocation. The fracture is often caused by major trauma in road accidents, at work or during sports, and patients usually present for total hip replacement (THR at an earlier age than the general arthritic population. We describe and analyze our patients with uncemented acetabular reconstruction in post-traumatic arthritis and compare them with THR in non-traumatic arthritis. Methods We retrospectively evaluated 19 patients who underwent uncemented acetabular reconstruction due to post-traumatic arthritis secondary to acetabular fracture. Results The average age at the time of arthroplasty was 52.2 years (19-83. The age at the time of fracture was 47.9 years (16-81. The average time between the acetabular fracture and THR was 52.4 months (4-360. The average follow-up was 4.25 years. No acetabular component loosening or infections were seen in either group. The Harris Hip Score at an average follow-up of 4.25 years was 89.3 (57-99. The follow-up in the control group with non-traumatic arthritis was 4.9 years, and the Harris Hip Score was 94.1 points (78-100. There were no significant difference in the Harris Hip Score between groups (p = 0.24. Conclusion Uncemented acetabular reconstruction in post-traumatic arthritis secondary to acetabular fracture is a more difficult procedure than routine arthroplasty in patient with non-traumatic arthritis. In the short-term there are no clinical or radiographic differences in THR with uncemented acetabular cups in post-traumatic arthritis patients compared to patients with non-traumatic arthritis.

  19. Is mortality after hip fracture associated with surgical delay or admission during weekends and public holidays?

    DEFF Research Database (Denmark)

    Daugaard, Cecilie Laubjerg; Jørgensen, Henrik L; Riis, Troels

    2012-01-01

    Hip fractures are associated with high mortality, but the cause of this is still not entirely clear. We investigated the effect of surgical delay, weekends, holidays, and time of day admission on mortality in hip fracture patients.......Hip fractures are associated with high mortality, but the cause of this is still not entirely clear. We investigated the effect of surgical delay, weekends, holidays, and time of day admission on mortality in hip fracture patients....

  20. Total hip replacement as primary treatment of unstable intertrochanteric fractures in elderly patients.

    Science.gov (United States)

    Sidhu, Amarjit Singh; Singh, Ajay Pal; Singh, Arun Pal; Singh, Sukhraj

    2010-08-01

    Fifty-three patients with A2.2 and A2.3 intertrochanteric fracture according to the Muller classification were treated with total hip replacement between April 2000 and February 2004. The average age of the patients was 77 years. Average follow-up period was 3.7 years. We studied postoperative complications, mortality rate, functional outcome using the Harris hip score, time to return to normal activities, and radiographic evidence of healing. Two patients died on the third and fifth postoperative days. Seven more patients died within one year. The Harris hip score at one month was 66 +/- 7 (mean +/- standard deviation); at three months 72 +/- 6; at one year 74 +/- 5; at three years 76 +/- 6 and in the 27 patients who completed five year follow-up it was 76 +/- 8. Mobilisation and weight-bearing was started immediately in the postoperative period. Average time taken to return to normal daily activities was 28 days (range 24-33). No loosening or infection of the implants was observed. Total hip arthroplasty is a valid treatment option for mobile and mentally healthy elderly patients with intertrochanteric fractures. This procedure offers quick recovery with little risk of mechanical failure, avoids the risks associated with internal fixation and enables the patient to maintain a good level of function immediately after surgery.

  1. Rigid internal fixation of zygoma fractures: A comparison of two-point and three-point fixation

    Directory of Open Access Journals (Sweden)

    Parashar Atul

    2007-01-01

    Full Text Available Background: Displaced fractures of the zygomatic bone can result in significant functional and aesthetic sequelae. Therefore the treatment must achieve adequate and stable reduction at fracture sites so as to restore the complex multidimensional relationship of the zygoma to the surrounding craniofacial skeleton. Many experimental biophysical studies have compared stability of zygoma after one, two and three-point fixation with mini plates. We conducted a prospective clinical study comparing functional and aesthetic results of two-point and three-point fixation with mini plates in patients with fractures of zygoma. Materials and Methods: Twenty-two patients with isolated zygomatic fractures over a period of one year were randomly assigned into two-point and three-point fixation groups. Results of fixation were analyzed after completion of three months. This included clinical, radiological and photographic evaluation. Results: The three-point fixation group maintained better stability at fracture sites resulting in decreased incidence of dystopia and enophthalmos. This group also had better malar projection and malar height as measured radiologically, when compared with the two-point fixation group. Conclusion: We recommend three-point rigid fixation of fractured zygoma after accurate reduction so as to maintain adequate stabilization against masticatory forces during fracture healing phase.

  2. Arthroscopic removal of intraarticular fragments following fracture dislocation of the hip

    Directory of Open Access Journals (Sweden)

    Bagaria Vaibhav

    2008-01-01

    Full Text Available We report here a case of posterior dislocation of hip with fracture of posterior lip of acetabulum, with retained fracture fragments after a successful closed reduction. The fractured fragments were removed by arthroscopy of the hip. The technique of hip arthroscopy used in removing the fragments is discussed.

  3. The incidence of symptomatic venous thromboembolism following hip fractures with or without surgery in Taiwan

    Directory of Open Access Journals (Sweden)

    Cheng-Han Lee

    2015-12-01

    Conclusions: The incidence of symptomatic VTE after hip fractures is low in Taiwan. Patients rarely received pharmacological thromboprophylaxis following hip fractures. Universal thromboprophylaxis for patients experiencing hip fractures was not necessary in Taiwan, but it should be considered in high-risk populations.

  4. Pedicle screw fixation against burst fracture of thoracolumbar vertebrae

    Institute of Scientific and Technical Information of China (English)

    L(U) Fu-xin; HUANG Yong; ZHANG Qiang; SHI Feng-lei; ZHAO Dong-sheng; HU Qiao

    2007-01-01

    Objective: To analyze the application of vertebral pedicle screw fixation in the treatment of burst fracture of thoracolumbar vertebrae.Methods: A total of 48 cases (31 males and 17 females, aged from 18-72 years, mean: 41.3 years) with thoracolumbar vertebrae burst fracture were treated by pedicle screw system since January 2004. According to the AO classification of thoracolumbar vertebrae fracture,there are 36 cases of Type A, 9 of Type B and 3 of Type C.Results: All patients were followed up for 6-25 months (average 12 months ), no secondary nerve root injury, spinal cord injury, loosening or breakage of pedicle screw were observed. The nerve function of 29 patients with cauda equina nerve injury was restored to different degrees. The vertebral body height returned to normal level and posterior process angle was rectified after operation.Conclusions: The vertebral pedicle screw internal fixation was technologically applicable, which can efficiently reposition and stablize the bursting fractured vertabrae,indirectly decompress canalis spinalis, maintain spine stablity, scatter stress of screw system, reduce the risk of loosening or breakage of screw and loss of vertebral height,and prevent the formation of posterior convex after operation.

  5. Zoledronic Acid in Reducing Clinical Fracture and Mortality after Hip Fracture

    DEFF Research Database (Denmark)

    Lyles, Kenneth W; Colón-Emeric, Cathleen S; Magaziner, Jay S

    2007-01-01

    BACKGROUND: Mortality is increased after a hip fracture, and strategies that improve outcomes are needed. METHODS: In this randomized, double-blind, placebo-controlled trial, 1065 patients were assigned to receive yearly intravenous zoledronic acid (at a dose of 5 mg), and 1062 patients were...... assigned to receive placebo. The infusions were first administered within 90 days after surgical repair of a hip fracture. All patients received supplemental vitamin D and calcium. The median follow-up was 1.9 years. The primary end point was a new clinical fracture. RESULTS: The rates of any new clinical...... infusion of zoledronic acid within 90 days after repair of a low-trauma hip fracture was associated with a reduction in the rate of new clinical fractures and improved survival. (ClinicalTrials.gov number, NCT00046254.)....

  6. A Review of Current Fixation Use and Registry Outcomes in Total Hip Arthroplasty

    DEFF Research Database (Denmark)

    Troelsen, Anders; Malchau, Erik; Sillesen, Nanna Hylleholt

    2013-01-01

    and to analyze age-stratified risk of revision comparing cemented, hybrid, and uncemented fixation as reported by national hip arthroplasty registries. METHODS: Data were extracted from the annual reports of seven national hip arthroplasty registries; we included all national registries for which annual reports...... were available in English or a Scandinavian language, if the registry had a history of more than 5 years of data collection. RESULTS: Current use of uncemented fixation in primary THAs varies between 15% in Sweden and 82% in Canada. From 2006 to 2010 the registries of all countries reported overall...... increases in the use of uncemented fixation; Sweden reported the smallest absolute increase (from 10% to 15%), and Denmark reported the greatest absolute increase (from 47% to 68%). Looking only at the oldest age groups, use of uncemented fixation also was increasing during the period. In the oldest age...

  7. Risk-factors for surgical delay following hip fracture.

    Science.gov (United States)

    Sanz-Reig, J; Salvador Marín, J; Ferrández Martínez, J; Orozco Beltrán, D; Martínez López, J F

    To identify pre-operative risk factors for surgical delay of more than 2 days after admission in patients older than 65 years with a hip fracture. A prospective observational study was conducted on 180 hip fractures in patients older than 65 years of age admitted to our hospital from January 2015 to April 2016. The data recorded included, patient demographics, day of admission, pre-fracture comorbidities, mental state, level of mobility and physical function, type of fracture, antiaggregant and anticoagulant medication, pre-operative haemoglobin value, type of treatment, and surgical delay. The mean age of the patients was 83.7 years. The mean Charlson Index was 2.8. The pre-fracture baseline co-morbidities were equal or greater than 2 in 70% of cases. Mean timing of surgery was 3.1 days. At the time of admission, 122 (67.7%) patients were fit for surgery, of which 80 (44.4%) underwent surgery within 2 days. A Charlson index greater than 2, anticoagulant therapy, and admission on Thursday to Saturday, were independently associated with a surgical delay greater than 2 days. The rate of hip fracture patients undergoing surgery within 2 days is low. Risk factors associated to surgical delay are non-modifiable. However, their knowledge should allow the development of protocols that can reduce surgical delay in this group of patients. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. The cost of screening radiographs after stable fracture fixation

    Science.gov (United States)

    Tufescu, Ted

    2017-01-01

    Background Currently up to 58% of Canadian surgeons would forego screening radiographs after stable fracture fixation. It is therefore expected that reducing screening radiographs will be well accepted, provided that patient safety is not compromised, resulting in a cost reduction. The study objective was to measure the savings of a simplified radiographic protocol for well-fixed fractures and establish feasibility for a noninferiority trial that proves patient safety. Methods Patients were randomized after fixation. The control group received screening radiographs immediately after fixation and at 2 weeks. The experimental group received radiographs only when clinically indicated. At 6 weeks all patients received radiographs. The cost of imaging, time spent in clinic and patient satisfaction was measured. A blinded reviewer documented adverse events, either detected or missed. Results Of the 90 patients screened, 39 were randomized and 26 had complete follow-up. The mean cost of radiographs over the first 6 weeks was $44.51 (95% confidence interval [CI] 38.64–50.38) per patient in the experimental group, and $129.23 (95% CI 120.23–138.23) in the control group (p The mean time spent in clinic at 2 weeks was 46 min (95% CI 32–60) per patient for the experimental group and 68 min (95% CI 55–81) for the control group (p = 0.018). Two complications occurred in the experimental group. Both were detected clinically and did not qualify as missed events. Conclusion Implementing a simplified radiography protocol after stable fracture fixation saves time and money. Additionally, no adverse events were missed with the study protocol. Recommendations are made toward a noninferiority trial to establish protocol safety. PMID:28234590

  9. Treatment of Gustilo grade Ⅲ leg fractures by external fixation associated with limited internal fixation

    Institute of Scientific and Technical Information of China (English)

    ZHANG Chun-qiang; ZHENG Hong-yu; WANG Bing; HUANG He; HE Fei; ZHAO Xue-ling

    2010-01-01

    Objective: To explore the clinical ef-fects of external fixation associated with limited internal fixa-tion on treatment of Gustilo grade Ⅲ leg fractures.Methods: From July 2006 to December 2008, 40 cases of Gustilo grade Ⅲ leg fiactures were emergently treated in our unit with external fixation frames.Soft tissue injuries were grouped according to the Gustilo classification as ⅢA in 17 cases, ⅢB in 13 cases, and ⅢC in 10 cases.All the patients were debrided within 8 hours, and then fracture reposition was preformed to reestablish the leg alignment.Limited internal fixation with plates and screws were per-formed on all the Gustilo Ilia cases and 10 Gustilo ⅢB cases at the first operation.But all the Gustilo ⅢC cases and 3 Gustilo ⅢB cases who had severe soft tissue injuries and bone loss only received Vacuum-sealing drainage (VSD).Broad-spectrum antibiotics were regularly used and VSD must be especially maintained easy and smooth for one week or more after operation.Limited internal fixation and transplanted free skin flaps or adjacent musculocutaneous flaps were not used to close wounds until the conditions of the wounds had been improved.Results: The first operations were completed within 90-210 minutes (170 minutes on average).The blood trans-fusions were from 400 ml to 1500 ml (those used for anti-shock preoperatively not included).All the 40 patients in this study were followed up for 6-28 months, 20.5 months on average.The lower limb function was evaluated accord-ing to the comprehensive evaluation standards of leg func-tion one year after operation and the results of 28 cases were excellent, 9 were good and 3 were poor.Conclusion: External fixation associated with limited internal fixation to treat Gustilo grade Ⅲ leg fractures can get satisfactory early clinical therapeutic effects.

  10. Geriatric hip fracture management: keys to providing a successful program.

    Science.gov (United States)

    Basu, N; Natour, M; Mounasamy, V; Kates, S L

    2016-10-01

    Hip fractures are a common event in older adults and are associated with significant morbidity, mortality and costs. This review examines the necessary elements required to implement a successful geriatric fracture program and identifies some of the barriers faced when implementing a successful program. The Geriatric Fracture Center (GFC) is a treatment model that standardizes the approach to the geriatric fracture patient. It is based on five principles: surgical fracture management; early operative intervention; medical co-management with geriatricians; patient-centered, standard order sets to employ best practices; and early discharge planning with a focus on early functional rehabilitation. Implementing a geriatric fracture program begins with an assessment of the hospital's data on hip fractures and standard care metrics such as length of stay, complications, time to surgery, readmission rates and costs. Business planning is essential along with the medical planning process. To successfully develop and implement such a program, strong physician leadership is necessary to articulate both a short- and long-term plan for implementation. Good communication is essential-those organizing a geriatric fracture program must be able to implement standardized plans of care working with all members of the healthcare team and must also be able to foster relationships both within the hospital and with other institutions in the community. Finally, a program of continual quality improvement must be undertaken to ensure that performance outcomes are improving patient care.

  11. Risk of hip fracture after osteoporosis fractures. 451 women with fracture of lumbar spine, olecranon, knee or ankle

    DEFF Research Database (Denmark)

    Lauritzen, J B; Lund, B

    1993-01-01

    In a follow-up study during 1976-1984, the risk of a subsequent hip fracture was investigated in women aged 60-99 years, hospitalized for the following fractures: lumbar spine (n 70), olecranon (n 52), knee (n 129) and ankle (n 200). Follow-up ranged from 0 to 9 years. Observation time of the 4...... different fractures were 241, 180, 469, and 779, person-years, respectively. In women aged 60-79 years with one of the following fractures the relative risk of a subsequent hip fracture was increased by 4.8 (lumbar spine), 4.1 (olecranon), 3.5 (knee) and 1.5 (ankle). The relative risk of hip fracture showed...

  12. [Distal fixation prosthesis for unstable intertrochanteric fractures in elderly patients: a mid-term follow-up study].

    Science.gov (United States)

    Zhang, Zhan-feng; Min, Ji-kang; Zhong, Jian-ming; Wang, Dan

    2016-06-01

    To explore mid-term follow up results of distal fixation prosthesis in treating unstable intertrochanteric fractures in elderly patients. From May 2008 to March 2014,58 elderly patients with unstable intertrochanteric were treated with distal fixation prosthesis, among them, there were 15 males and 43 females aged from 75 to 87 years old with an average of 83.2 years old. Fracture were classified according to Evans classification, 39 cases were type I c and 19 cases were type I d. Surgical risk was evaluated before operation, 9 patients were performed total hip arthroplasty and 49 patients were performed prosthetic replacement hip joint function of patients with different age period, Evans classificaton, prothesis type, fixation method were evaluated respectively by using Harris score. Fifty-six patients were followed up from 13 to 36 months with an average of 21.6 months. Harris score was 83.51 ± 6.40, 5 cases got excellent results, 38 cases good and 13 cases moderate. Harris score of patients aged from 75 to 80 years old was 88.64 ± 2.35, 81.64 ± 6.40 in patients aged more than 80 years old, and had significant differences between two groups; Harris score in patients with type Evans I c was 83.64 ± 6.53, and 83.11 ± 6.08 in type Evans I d, while there was no significant differences between two groups. There was no obvious meaning in Harris score between patients with tension band (83.63 ± 6.15) and without tension band (82.41 ± 6.57). There was no significant meaning in Harris score between patients with normal distal fixation prosthesis (83.34 ± 6.43) and femoral moment reconstruction distal fixation prosthesis (83.92 ± 6.51). There was 1 patient occurred hip joint dislocation on the operative side and re-dislocation after manual reduction, then received open reduction. Two patients occurred femoral osteolysis without clinical symptoms, and treated conservative treatment. Artificial joint replacement for unstable intertrochanteric fractures in elderly

  13. Mechanical design optimization of bioabsorbable fixation devices for bone fractures.

    Science.gov (United States)

    Lovald, Scott T; Khraishi, Tariq; Wagner, Jon; Baack, Bret

    2009-03-01

    Bioabsorbable bone plates can eliminate the necessity for a permanent implant when used to fixate fractures of the human mandible. They are currently not in widespread use because of the low strength of the materials and the requisite large volume of the resulting bone plate. The aim of the current study was to discover a minimally invasive bioabsorbable bone plate design that can provide the same mechanical stability as a standard titanium bone plate. A finite element model of a mandible with a fracture in the body region is subjected to bite loads that are common to patients postsurgery. The model is used first to determine benchmark stress and strain values for a titanium plate. These values are then set as the limits within which the bioabsorbable bone plate must comply. The model is then modified to consider a bone plate made of the polymer poly-L/DL-lactide 70/30. An optimization routine is run to determine the smallest volume of bioabsorbable bone plate that can perform and a titanium bone plate when fixating fractures of this considered type. Two design parameters are varied for the bone plate design during the optimization analysis. The analysis determined that a strut style poly-L-lactide-co-DL-lactide plate of 690 mm2 can provide as much mechanical stability as a similar titanium design structure of 172 mm2. The model has determined a bioabsorbable bone plate design that is as strong as a titanium plate when fixating fractures of the load-bearing mandible. This is an intriguing outcome, considering that the polymer material has only 6% of the stiffness of titanium.

  14. Dementia and delirium, the outcomes in elderly hip fracture patients

    NARCIS (Netherlands)

    Mosk, C.A. (Christina A.); Mus, M. (Marnix); Vroemen, J.P.A.M. (Jos P. A. M.); T. van der Ploeg (Tjeerd); D.I. Vos (Dagmar); Elmans, L.H.G.J. (Leon H. G. J.); L. van der Laan (Lyckle)

    2017-01-01

    textabstractBackground: Delirium in hip fractured patients is a frequent complication. Dementia is an important risk factor for delirium and is common in frail elderly. This study aimed to extend the previous knowledge on risk factors for delirium and the consequences. Special attention was given to

  15. Electrocardiographic abnormalities in patients admitted for hip fracture

    NARCIS (Netherlands)

    Goslings, J C; Schafroth, M U; de Rooij, S E J A; Jansen, S.; Koster, R.W.; de Lange, F.J.; van der Velde, N

    2014-01-01

    BACKGROUND: Several risk factors for falls and hip fractures have been recognised, but controversy still exists regarding the importance of rhythm and conduction abnormalities as potentially modifiable risk factors for recurrent falls. The aim of this study was to determine the prevalence of

  16. The risk of second hip fracture is decreased with compliant and persistent use of bisphosphonates

    DEFF Research Database (Denmark)

    Hansen, Louise; Vestergaard, Peter; Petersen, Karin Dam

    on the medical assumption that 50% of additional hip fractures may be prevented with compliant and persistent use of alendronate in five years following the initial fracture. RESULTS: In the no treatment arm, the average cost was EUR 16,233 and 0.32 hip fractures per woman, and in the alendronate treatment arm...... the average cost was EUR 13,395 and 0.17 hip fractures per woman. The incremental cost-effectiveness ratio (ICER) resulted in a cost saving of EUR 18,623 per prevented hip fracture. In the alendronate treatment arm, the average cost and effect was EUR 5,631 and 0.16 hip fractures per man. The no treatment arm...... the first month after fracture and does not normalise until 15 years later. Fracture prevention programs have focused on identifying patients at risk of secondary low energy trauma fractures. The secondary prevention programs for fractures begin immediately after the first fracture, through identification...

  17. Acute periprosthetic fractures of the acetabulum after total hip arthroplasty.

    Science.gov (United States)

    Potty, Anish G; Corona, Jacqueline; Manning, Blaine T; Le, Amanda; Saleh, Khaled J

    2014-01-01

    Although periprosthetic fractures of the acetabulum are relatively uncommon after total hip arthroplasty, a variety of patient-, surgeon-, and implant-related risk factors can contribute to the occurrence of this serious complication. These risk factors, combined with the increased use of cementless acetabular cups, will likely result in an increased prevalence of these fractures in the future. By better understanding the risk factors, classification schemes, and treatment options for periprosthetic fractures of the acetabulum, orthopaedic surgeons can achieve better outcomes for their patients.

  18. Effectiveness of treatment of transtrochanteric fractures with Dynamic Hip Screws using minimally invasive access☆

    Science.gov (United States)

    de Abreu, Eduardo Lima; Sena, Caroline Brum; Saldanha Rodrigues Filho, Sergio Antonio

    2016-01-01

    Objective To analyze the short-term results from treating unstable intertrochanteric fractures with Dynamic Hip Screws (DHS), using a minimally invasive route, focusing on the functional aspects and complication and mortality rates of the method. Methods This was a prospective longitudinal study on 140 patients who underwent fixation of transtrochanteric fractures with the DHS system with a lateral minimally invasive access in the hip, between January and December 2013. The patients were evaluated pre and postoperatively (after six months of follow-up) by means of the Parker and Palmer mobility score. Women comprised 65.7% of the sample, and 54.3% of the fractures were on the right side. The patients’ mean age was 80 years, ranging from 60 to 93 years. Results We observed an overall decrease in the mobility score and an increase in the degree of dependence over the short term. However, we encountered only two deaths in the study sample and there were no cases of infection or nonunion. Conclusion Despite the efficacy of the treatment with DHS, with high rates of fracture consolidation and a low mortality rate, we noted that the patients still showed significant functional limitation at the follow-up six months after the operation. PMID:27069880

  19. Factors influencing postoperative mortality one year after surgery for hip fracture in Chinese elderly population

    Institute of Scientific and Technical Information of China (English)

    LI Shao-guang; SUN Tian-sheng; LIU Zhi; REN Ji-xin; LIU Bo; GAO Yang

    2013-01-01

    Background Disability and death following hip fracture is becoming more common as the population ages.Previous reports have focused on the selection of internal fixation methods and the analysis of the perioperative therapeutic results in the Chinese population.Few studies have focused on factors influencing medium and long term survival after surgery for hip fracture.We conducted a retrospective study on the factors influencing survival one year after hip fracture surgery in our elderly Chinese population to provide a reference for improved treatment and to enhance efficacy.Methods Records from patients undergoing treatment for hip fracture at our hospital from October 2009 through June 2011 were retrospectively reviewed.Through telephone follow-up,the health condition of each patient was surveyed,and the 1-year postoperative mortality was analyzed.The patients' age,gender,fracture type,pre-injury health condition,mobility,complications,surgical timing,surgical types,methods of anesthesia,and postoperative complications were analyzed.Univariate and multivariate regression analysis was performed on relevant influencing factors.Results A total of 184 patients had complete data and were followed-up for 12-23 months (average,16.5 months).There were 30 deaths (16.3%) at one-year.Univariate analysis revealed that factors such as age,gender,fracture-type,number of co-existing diseases,complications such as chronic obstructive pulmonary disease or sequelae of stroke,American society of Anesthesiology (ASA) scores,anesthesia methods,pre-injury activity,and post-operative complications were significantly different between survival versus mortality groups (P <0.05).Multivariate regression analysis revealed that age,ASA score,pre-injury mobility and combined chronic obstructive pulmonary disease were independent risk factors for death.Conclusion Full consideration of medium-/long-term risk factors in the treatment of hip fracture in the elderly,selection of appropriate

  20. Tosic external fixator in the management of proximal tibial fractures in adults.

    Science.gov (United States)

    Tosic, A; Ebraheim, N A; Abou Chakra, I; Emara, K

    2001-06-01

    This retrospective clinical study assessed proximal tibial fractures managed with the Tosic external fixator. Nineteen patients with 21 proximal tibial fractures treated with the Tosic external fixator between July 1997 and October 1998 comprised the study population. Eleven fractures were graded as 41A2, 3 fractures as 41 A3, 4 fractures as 41C1, and 3 fractures as 41 C2. Fourteen fractures were closed, and 7 fractures were open. Average time to healing was 1 7 weeks. No revision of fixation was needed. There were five cases of pin tract infection. Average range of knee motion was 2 degrees-135 degrees. These results indicate the Tosic external fixator is an efficient and simple way to treat proximal tibial metaphyseal fractures.

  1. Risk Factors for Hip Fracture in Older Home Care Clients

    Science.gov (United States)

    Poss, Jeff; Cook, Richard J.; Byrne, Kerry; Hirdes, John P.

    2009-01-01

    Background Little information is available on hip fracture risks among community-dwelling persons receiving home care. Our aim was to identify risk factors for hip fracture from health information routinely collected for older home care clients. Methods This was a cohort study involving secondary analysis of data on 40,279 long-stay (>60 days) home care clients aged 65 and older in Ontario, Canada; occurrence of hip fracture as well as potential risk factor information were measured using the Resident Assessment Instrument (RAI)/Minimum Data Set–Home Care assessment instrument. Results In all, 1,003 clients (2.5%) had hip fracture on follow-up assessment. Older (85+ vs 65–74, relative risk [95% confidence interval]: 0.52 [0.43–0.64]) clients are at increased risk; males are at reduced risk [0.60 (0.51–0.70)]. Other risk factors include osteoporosis (1.19 [1.03–1.36]), falls (1.31 [1.15–1.49]), unsteady gait (1.18 [1.03–1.36]), use of ambulation aide (1.39 [1.21–1.59]), tobacco use (1.42, [1.13–1.80]), severe malnutrition (2.61 [1.67–4.08]), and cognitive impairment (1.30 [1.12–1.51]). Arthritis (0.86 [0.76–0.98]) and morbid obesity (0.34 [0.16–0.72]) were associated with reduced risk. Males and females demonstrated different risk profiles. Conclusions Important risk factors for hip fracture can be identified from routinely collected data; these could be used to identify at-risk clients for further investigation and prevention strategies [22]. PMID:19196903

  2. Comparative study of the results of compound tibial shaft fractures treated by Ilizarov ring fixators and limb reconstruction system fixators

    Institute of Scientific and Technical Information of China (English)

    Chandra Prakash Pal; Harish Kumar; Deepak Kumar; K.S.Dinkar; Vivek Mittal; Naveen Kumar Singh

    2015-01-01

    Purpose: Ilizarov ring fixator and limb reconstruction system (LRS) fixators have been used in the management of complex tibial fractures with severe soft tissue injuries, compound tibial fractures, and infected tibial nonunion for which conventional internal fixation cannot be contemplated.Fracture union and distraction osteogenesis can be done simultaneously with these external fixators, allowing early weight bearing.Several previous studies have shown almost equal results of rail and ring fixators for the compound tibial shaft fractures.Thus we performed a prospective study to evaluate the union rate, functional outcome and amount of limb lengthening after the treatment of compound tibial shaft fractures with or without infected nonunion by ring or LRS fixators.Methods: This prospective study was done at Sarojini Naidu Medical College and Hospital, Agra, India and included 32 patients of compound tibial shaft fractures with or without infected nonunion.There were 26 males and 6 females and the average age was 40 years.Patients were randomly divided into two groups (n =16 for each): one underwent Ilizarov fixation and the other received LRS fixation.Cases were followed up for 3-24 months, 6 months on average from September 2012 to October 2014.Functional and radiological outcomes were assessed using the Association for the Study and Application of Methods of Ilizarov (ASAMI) criteria for both rail and ring fixators.Results: Union was achieved in all cases.Radiological outcome was found excellent in 68.75%, good in 18.75% and fair in 12.50% of cases treated by rail fixators whereas it was excellent in 56.25%, good in 18.75%, fair in 12.50% and poor in 12.50% of cases treated by ring fixators.Functional result was satisfactory in 75.00% of cases treated by rail fixator and 68.75% of cases treated by ring fixators whereas the corresponding rate of unsatisfactory was 25.00% vs.31.25%.Conclusion: In our short-term assessment, LRS fixators show a

  3. [Complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    Science.gov (United States)

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2016-12-20

    Objective: To make a systematic assessment of the complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Method: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed.The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected.The included trials were screened out strictly based on the criterion of inclusion and exclusion.The quality of included trials was evaluated.RevMan 5.0 was used for data analysis. Result: A total of 17 studies involving 1 402 patients were included.There were 687 patients with open reduction and internal fixation and 715 with external fixation.The results of Meta-analysis indicated that there were statistically significant differences with regard to the postoperatively total complications, infection, malunion, tendon rupture (I(2)=8%, RR=0.77(95%CI 0.65-0.91, Z=3.10, P0.05). Conclusion: Postoperative complications are present in both open reduction and internal fixation and external fixation.Compared with external fixation, open reduction and internal fixation is lower in total complications postoperatively, infection and malunion, but external fixation has lower tendon rupture incidence.

  4. Prediction of early mortality following hip fracture surgery in frail elderly : The Almelo Hip Fracture Score (AHFS)

    NARCIS (Netherlands)

    Nijmeijer, W. S.; Folbert, E. C.; Vermeer, M.; Slaets, J. P.; Hegeman, J. H.

    2016-01-01

    Background: Hip fractures are common in the elderly and have a high risk of early mortality. Identification of patients at high risk of early mortality could contribute to enhanced quality of care. A simple scoring system is essential for preoperative identification of patients at high risk of early

  5. Geographic Variation in Hip Fracture Among United States Long-Stay Nursing Home Residents

    Science.gov (United States)

    Banerjee, Geetanjoli; Zullo, Andrew R.; Berry, Sarah D.; Lee, Yoojin; McConeghy, Kevin; Kiel, Doug P.; Mor, Vincent

    2016-01-01

    Introduction Despite high rates of hip fracture among United States (US) nursing home (NH) residents, little is known about geographic variation in hip fracture incidence. We used nationally representative data to identify geographic variation in hip fracture among US NH residents. Design and setting Retrospective cohort study using Part A claims for a 100% of Medicare enrollees in 15,289 NHs linked to NH minimum data set and Online Survey, Certification, and Reporting databases. Participants A total of 891,085 long-stay (continuous residence of ≥100 days) NH residents ≥65 years old. Measurements Medicare Part A claims documenting a hip fracture. Mean incidence rates of hip fracture for long-stay NH residents were calculated for each state and US Census Division from 2007 to 2010. Results The age-, sex-, and race-adjusted incidence rate of hip fracture ranged from 1.49 hip fractures/100 person-years (Hawaii) to 3.60 hip fractures/100 person-years (New Mexico), with a mean of 2.38 (standard deviation 0.43) hip fractures/100 person-years. The mean incidence of hip fracture was 1.7-fold greater in the highest quintile than the lowest. Conclusions We observed modest US state and regional variation in hip fracture incidence among long-stay NH residents. Future studies should assess whether state policies or NH characteristics explain the variation. PMID:27461867

  6. Outcomes of osteoporotic trochanteric fractures treated with cement-augmented dynamic hip screw

    Directory of Open Access Journals (Sweden)

    Rakesh Kumar Gupta

    2012-01-01

    Full Text Available Background: Dynamic hip screw (DHS has been the standard treatment for stable trochanteric fracture patterns, but complications of lag screw cut out from a superior aspect, due to inadequate bone anchorage, occur frequently in elderly osteoporotic patients. Polymethylmethacrylate (PMMA has been used as an augmentation tool to facilitate fixation stability in cadaveric femora for biomechanical studies and in pathological fractures. However, there are very few reports on the utilization of PMMA cement to prevent these complications in fresh intertrochanteric fractures. A prospective study was conducted to evaluate the outcome and efficacy of PMMA augmented DHS in elderly osteoporotic patients with intertrochanteric fractures. Materials and Methods: The study included 64 patients (AO type31-A2.1 in eight, A2.2 in 29, A2.3 in 17 patients, and 31-A3.1 in five, A3.2 in three, and A3.3 in two patients with an average age of 72 years (60 − 94 years of which 60 were available for final followup. PMMA augmentation of DHS was performed in all cases by injecting PMMA cement into the femoral head with a custommade gun designed by the authors. The clinical outcome was rated as per the Salvati and Wilson scoring system at the time of final followup of one year. Results were graded as excellent (score > 31, good (score 24 − 31, fair (score 16 − 23, and poor (score < 16. Results: Fracture united in all patients and the average time to union was 13.8 weeks (range 12 − 16 weeks. At an average followup of 18 months (range 12 − 24 months, no incidence of varus collapse or superior screw cut out was observed in any of the patients in spite of weightbearing ambulation from the early postoperative period. There was no incidence of avascular necrosis (AVN or cement penetration into the joint in our series. Most of the patients were able to regain their prefracture mobility status with a mean hip pain score of 8.6. Conclusion: Cement augmentation of DHS appears

  7. [Is Mapuche ethnicity a risk factor for hip fracture in aged?].

    Science.gov (United States)

    Sapunar, Jorge; Bravo, Paulina; Schneider, Hermann; Jiménez, Marcela

    2003-10-01

    Ethnic factors are involved in the risk for osteoporosis and hip fracture. To assess the effect of Mapuche ethnicity on the risk of hip fracture. A case control study. Cases were subjects over 55 years of age admitted, during one year, for hip fracture not associated to major trauma or tumors. Controls were randomly chosen from other hospital services and paired for age with cases. The magnitude of the association between ethnicity and hip fracture was expressed as odds ratio in a logistic regression model. In the study period, 156 cases with hip fracture were admitted. The proportion of subjects with Mapuche origin was significantly lower among cases than controls (11.8 and 26.5% respectively, p Mapuche ethnicity was associated with hip fracture with an odds radio of 0.14 (p = 0.03, 95% CI 0.03-0.8). In this sample, Mapuche ethnicity is a protective factor for hip fracture.

  8. Radial and humeral fractures as predictors of subsequent hip, radial or humeral fractures in women, and their seasonal variation

    DEFF Research Database (Denmark)

    Lauritzen, J B; Schwarz, Peter; McNair, P;

    1993-01-01

    Hip fractures are common in elderly women, and early risk assessment of future hip fractures is relevant in relation to prevention. We studied the predictive value of radial and humeral fractures in women. The influence of weather conditions on the risk was also studied. Women aged 20-99 years wi...

  9. Minimum Lateral Bone Coverage Required for Securing Fixation of Cementless Acetabular Components in Hip Dysplasia

    Directory of Open Access Journals (Sweden)

    Masanori Fujii

    2017-01-01

    Full Text Available Objectives. To determine the minimum lateral bone coverage required for securing stable fixation of the porous-coated acetabular components (cups in hip dysplasia. Methods. In total, 215 primary total hip arthroplasties in 199 patients were reviewed. The average follow-up period was 49 months (range: 24–77 months. The lateral bone coverage of the cups was assessed by determining the cup center-edge (cup-CE angle and the bone coverage index (BCI from anteroposterior pelvic radiographs. Further, cup fixation was determined using the modified DeLee and Charnley classification system. Results. All cups were judged to show stable fixation by bone ingrowth. The cup-CE angle was less than 0° in 7 hips (3.3% and the minimum cup-CE angle was −9.2° (BCI: 48.8%. Thin radiolucent lines were observed in 5 hips (2.3%, which were not associated with decreased lateral bone coverage. Loosening, osteolysis, dislocation, or revision was not observed in any of the cases during the follow-up period. Conclusion. A cup-CE angle greater than −10° (BCI > 50% was acceptable for stable bony fixation of the cup. Considering possible errors in manual implantation, we recommend that the cup position be planned such that the cup-CE angle is greater than 0° (BCI > 60%.

  10. Fibular fracture stabilization with a guidewire as supplementary fixation in tibia fractures.

    Science.gov (United States)

    Dombroski, Derek; Scolaro, John A; Pulos, Nicholas; Beingessner, Daphne M; Dunbar, Robert; Mehta, Samir

    2012-11-01

    We present a novel technique of intramedullary fixation of the fibula using a humeral guide wire as an adjunct to tibial fixation, in the setting of tibial shaft fracture. Not only does this technique aid in determining length, alignment, and rotation of the tibial fracture, but it may also help the support of the lower extremity as whole by stabilizing the lateral column. In addition, this technique can be used to help maintain reduction of the fibula when there is concern for the soft tissues of the lower extremity secondary to swelling or injury. Our clinical case series demonstrates this safe, effective, and cost-sensitive technique to be used in the treatment of select concurrent fractures of the tibia and fibula.

  11. Are Hip-Specific Items Useful in a Quality of Life Questionnaire for Patients with Hip Fractures?

    Science.gov (United States)

    Yao, Kai-Ping Grace; Lee, Hsin-Yi; Tsauo, Jau-Yih

    2009-01-01

    Researchers measure the significance of hip fracture by the patient's impairment. The patient's quality of life (QOL) is usually also substantially affected. However, there is no specific quality of life (QOL) questionnaire for patients with hip fractures. This study was designed to determine whether adding a new set of specific questions about…

  12. Prevalent vertebral fractures on chest CT: higher risk for future hip fracture.

    Science.gov (United States)

    Buckens, Constantinus F; de Jong, Pim A; Mali, Willem P; Verhaar, Harald J; van der Graaf, Yolanda; Verkooijen, Helena M

    2014-02-01

    Subclinical or undiagnosed vertebral fractures on routine chest computed tomography (CT) may be useful for detecting patients at increased risk of future hip fractures who might benefit from preventive interventions. We investigated whether prevalent vertebral fractures on routine chest CT are associated with future hip fractures. From a source population of 5679 patients ≥40 years old undergoing chest CT in one of three Dutch hospitals between 2002 and 2005, patients hospitalized for hip fractures (n = 149) during a median follow-up of 4.4 years were identified. Following a case-cohort design, a random sample of 576 patients was drawn from the source population and added to the cases. In this group, the presence and severity of vertebral fractures was determined using semiquantitative vertebral fracture assessment and multivariate case-cohort appropriate Cox modeling. We found that cases were older (69 versus 63 years) and more often female (48% versus 38%) than the source population. Compared with those with no fracture, patients with any vertebral fracture had triple the risk of future hip fracture (age- and gender-adjusted hazard ratio [HR] = 3.1, 95% confidence interval [CI] 2.1-4.7). This HR rose to 3.8 (CI 2.6-5.6) if mild fractures were discounted. Future fracture risk increased significantly with increasing severity of vertebral fracture status: from mild (HR = 2.4, CI 1.5-3.7) and moderate (HR = 4.8, CI 2.5-9.2) to severe (HR = 6.7, CI 2.9-15.5). The same was true for having higher cumulative fracture grades: 1 to 3 (HR = 2.7, CI 1.8-4.1), 4 to 6 (HR = 4.8, CI 2.2-10.5), or ≥7 (HR = 11.2, CI 3.7-34.6). In conclusion, prevalent vertebral fractures on routine clinical chest CT are associated with future hip fracture risk. © 2014 American Society for Bone and Mineral Research.

  13. Minimally invasive percutaneous compression plating versus dynamic hip screw for intertrochanteric fractures: a randomized control trial

    Institute of Scientific and Technical Information of China (English)

    Cheng Qiang; Huang Wei; Gong Xuan; Wang Changdong; Liang Xi; Hu Ning

    2014-01-01

    Objective:Intertrochanteric femur fracture is a common injury in elderly patients.The dynamic hip screw (DHS) has served as the standard choice for fixation; however it has several drawbacks.Studies of the percutaneous compression plate (PCCP) are still inconclusive in regards to its efficacy and safety.By comparing the two methods,we assessed their clinical therapeutic outcome.Methods:Atotal of 121 elderly patients with intertrochanteric femur fractures (type AO/OTA 31.A 1-A2,Evans type 1) were divided randomly into two groups undergoing either a minimally invasive PCCP procedure or a conventional DHS fixation.Results:The mean operation duration was significantly shorter in the PCCP group (55.2 min versus 88.5 min,P<0.01).The blood loss was 156.5 ml±18.3 ml in the PCCP group and 513.2 ml±66.2 ml in the DHS group (P<0.01).Among the patients treated with PCCP,3.1% needed blood transfusions,compared with 44.6% of those that had DHS surgery (P<0.01).The PCCP group displayed less postoperative complications (P<0.05).The mean American Society of Anesthesiologists score and Harris hip score in the PCCP group were better than those in the DHS group.There were no significant differences in the mean hospital stay,mortality rates,or fracture healing.Conclusion:Due to several advantages,PCCP has the potential to become the ideal choice for treating intertrochanteric fractures (type AO/OTA 31.A1-A2,Evans type 1),particularly in the elderly.

  14. Effects of Hip Geometry on Fracture Patterns of Proximal Femur

    Directory of Open Access Journals (Sweden)

    Seyyed Morteza Kazemi

    2016-07-01

    Full Text Available Background: Some studies have previously shown that geometry of proximal femur can affect the probability of fracture and type of fracture. It happens since the geometry of the proximal femur determines how a force is applied to its different parts. In this study, we have compared proximal femur’s geometric characteristics in femoral neck (FNF, intertrochanteric (ITF and Subtrochanteric (STF fractures. Methods: In this study, 60 patients who had hip fractures were studied as case studies. They were divided into FNF, ITF and STF groups based on their fracture types (20 patients in each group. Patients were studied with x-ray radiography and CT scans. Radiological parameters including femoral neck length from lateral cortex to center of femoral head (FNL, diameter of femoral head (FHD, diameter of femoral neck (FND, femoral head neck offset (FHNO, neck-shaft angle (alpha, femoral neck anteversion (beta were measured and compared in all three groups. Results: Amount of FNL was significantly higher in STF group compared to FNF (0.011 while ITF and STF as well as FNT and ITF did not show a significant different. Also, FND in FNF group was significantly lower than the other two groups, i.e. ITF and STF. In other cases there were no instances of significant statistical difference. Conclusion: Hip geometry can be used to identify individuals who are at the risk of fracture with special pattern. Also, it is important to have more studies in different populations and more in men.

  15. Effects of Hip Geometry on Fracture Patterns of Proximal Femur

    Science.gov (United States)

    Kazemi, Seyyed Morteza; Qoreishy, Mohamad; Keipourfard, Ali; Sajjadi, Mohammadreza Minator; Shokraneh, Shahram

    2016-01-01

    Background: Some studies have previously shown that geometry of proximal femur can affect the probability of fracture and type of fracture. It happens since the geometry of the proximal femur determines how a force is applied to its different parts. In this study, we have compared proximal femur’s geometric characteristics in femoral neck (FNF), intertrochanteric (ITF) and Subtrochanteric (STF) fractures. Methods: In this study, 60 patients who had hip fractures were studied as case studies. They were divided into FNF, ITF and STF groups based on their fracture types (20 patients in each group). Patients were studied with x-ray radiography and CT scans. Radiological parameters including femoral neck length from lateral cortex to center of femoral head (FNL), diameter of femoral head (FHD), diameter of femoral neck (FND), femoral head neck offset (FHNO), neck-shaft angle (alpha), femoral neck anteversion (beta) were measured and compared in all three groups. Results: Amount of FNL was significantly higher in STF group compared to FNF (0.011) while ITF and STF as well as FNT and ITF did not show a significant different. Also, FND in FNF group was significantly lower than the other two groups, i.e. ITF and STF. In other cases there were no instances of significant statistical difference. Conclusion: Hip geometry can be used to identify individuals who are at the risk of fracture with special pattern. Also, it is important to have more studies in different populations and more in men. PMID:27517071

  16. Hip Fracture-Related Pain Strongly Influences Functional Performance of Patients With an Intertrochanteric Fracture Upon Discharge From the Hospital

    DEFF Research Database (Denmark)

    Kristensen, Morten Tange

    2013-01-01

    OBJECTIVE: To examine whether functional performance upon hospital discharge is influenced by pain in the region of the hip fracture or related to the fracture type. DESIGN: Prospective observational study. SETTING: A 20-bed orthopedic hip fracture unit. PATIENTS: Fifty-five cognitively intact...... testing (P fracture type, day of TUG performance, and pain intensity....... Multivariate linear regression analyses (fracture type not included) showed that only greater age (B = 0.34), low prefracture function (B = 7.9), and experiencing moderate to severe pain (B = 8.7) were independently associated with having a poorer TUG score. CONCLUSIONS: Hip fracture-related pain primarily...

  17. Central dislocation of the hip secondary to insufficiency fracture

    Directory of Open Access Journals (Sweden)

    Moe Thaya

    2010-03-01

    Full Text Available We present a case report of a 45-year old man who sustained a central dislocation of the hip secondary to an insufficiency fracture of the acetabulum. At the time of presentation he was on alendronate therapy for osteoporosis which had been previously investigated. CT scanning of the pelvis was useful for pre-operative planning which confirmed collapse of the femoral head but no discontinuity of the pelvis. The femoral head was morcellized and used as bone graft for the acetabular defect and an uncemented total hip replacement was performed.

  18. Bilateral traumatic proximal humerus fractures managed by open reduction and internal fixation with locked plates

    Directory of Open Access Journals (Sweden)

    Jaiswal Atin

    2013-12-01

    Full Text Available 【Abstract】Fractures of the proximal humerus are uncommon in young patients. Although bilateral fracture of proximal humerus itself is rare, association with epilepsy and electrocution is frequent. Only one case of traumatic bilateral proximal humerus fracture has been reported in the literature. We report a rare case of bilateral traumatic dis- placed proximal humerus fractures in a 40 years old male patient, which was treated by means of open reduction and internal fixation with proximal humerus locked pates on both sides and obtained a good functional outcome. Key words: Humeral fractures; Shoulder fractures; Fracture fixation, internal

  19. Meaningful improvement in gait speed in hip fracture recovery.

    Science.gov (United States)

    Alley, Dawn E; Hicks, Gregory E; Shardell, Michelle; Hawkes, William; Miller, Ram; Craik, Rebecca L; Mangione, Kathleen K; Orwig, Denise; Hochberg, Marc; Resnick, Barbara; Magaziner, Jay

    2011-09-01

    To estimate meaningful improvements in gait speed observed during recovery from hip fracture and to evaluate the sensitivity and specificity of gait speed changes in detecting change in self-reported mobility. Secondary longitudinal data analysis from two randomized controlled trials Twelve hospitals in the Baltimore, Maryland, area. Two hundred seventeen women admitted with hip fracture. Usual gait speed and self-reported mobility (ability to walk 1 block and climb 1 flight of stairs) measured 2 and 12 months after fracture. Effect size-based estimates of meaningful differences were 0.03 for small differences and 0.09 for substantial differences. Depending on the anchor (stairs vs walking) and method (mean difference vs regression), anchor-based estimates ranged from 0.10 to 0.17 m/s for small meaningful improvements and 0.17 to 0.26 m/s for substantial meaningful improvement. Optimal gait speed cutpoints yielded low sensitivity (0.39-0.62) and specificity (0.57-0.76) for improvements in self-reported mobility. Results from this sample of women recovering from hip fracture provide only limited support for the 0.10-m/s cut point for substantial meaningful change previously identified in community-dwelling older adults experiencing declines in walking abilities. Anchor-based estimates and cut points derived from receiver operating characteristic curve analysis suggest that greater improvements in gait speed may be required for substantial perceived mobility improvement in female hip fracture patients. Furthermore, gait speed change performed poorly in discriminating change in self-reported mobility. Estimates of meaningful change in gait speed may differ based on the direction of change (improvement vs decline) or between patient populations. © 2011, Copyright the Authors. Journal compilation © 2011, The American Geriatrics Society.

  20. Risk Factors for Hip Fractures in Elderly Patients

    Directory of Open Access Journals (Sweden)

    Erhan Bayram

    2014-09-01

    Full Text Available Aim: In this study, we aimed to determine the risk factors for hip fractures in elderly patients in order to contribute to efforts to reduce the incidence of hip fractures. Methods: We evaluated 54 patients aged 79.12±8.83 (range: 55-95 years, who presented to our emergency department due to hip fractures (Group 1 and 52 hospitalized patients aged 69.04±7.66 (range: 60-83 years, without a hip fracture (Group 2. We compare the groups in terms of neuropathy symptom score (NSS, neurological impairment score (NIS, accompanying diseases, foot deformities, dermal and nail problems, body mass index (BMI, osteoporosis, and use of walking aid devices. Results: The mean BMI score was 24.81±3.67 and 27.67±4.86 in Group 1 and in Group 2, respectively. The difference was statistically significant (p=0.001. The mean NSS and NIS in Group 1 was 2.87±2.89 and 2.06±1.17, respectively, while the mean NSS was 1.83±2.84 and NIS was 0.6±0.82 in group 2. The two scores were higher in group 1 than in Group 2, however, the difference in NISs between the groups was statistically significant (p<0.001. In Group 1, the number of patients smoking or drinking alcohol was higher than in Group 2, but the difference was not significant (p=0.37, p=0.324. There were no significant relationship between foot deformities and hip fractures. The number of patients with osteoporosis and those using walking aid devices was significantly higher in Group 1 than in Group 2 (p=0.007, p<0.001. Conclusion: In this study including a limited number of patients, we determined that a low BMI score, osteoporosis, and use of walking aid device are the risk factors for hip fractures. (The Me­di­cal Bul­le­tin of Ha­se­ki 2014; 52: 187-90

  1. Age Related Incidence and Early Outcomes of Hip Fractures: A Prospective Cohort Study of 1177 patients

    OpenAIRE

    Shenoy Ravikiran; Eranki Vivek; Pillai Anand; Hadidi Mahar

    2011-01-01

    Abstract Introduction Associated with the increase in the aging population, there is an increase in the incidence of hip fractures worldwide. Outcome following such fractures is affected by age of the patient. This study aims to assess the incidence and early outcome of hip fractures, comparing between different age groups. Methods Data of hip fractures collected over a period of five years was analysed. Patients were divided into three groups, group A (patients under the age of 64), group B ...

  2. Caspar plate fixation for the treatment of complex hangman's fractures.

    Science.gov (United States)

    Tuite, G F; Papadopoulos, S M; Sonntag, V K

    1992-05-01

    This report details our recent experience with the surgical treatment of complex hangman's fractures after failure of closed reduction and immobilization in external orthosis. We have successfully treated hangman's fractures in 5 patients with anterior Caspar plate stabilization and C2-C3 interbody fusion. The specific anatomical features of these fractures were complex, rendering the spines of the patients highly unstable. The patients were considered surgical candidates when reduction could not be achieved or maintained with axial traction or halo immobilization. Each patient underwent anterior C2-C3 interbody bone fusion and Caspar plating from C2 to C3. All patients achieved adequate intraoperative reduction and were immobilized postoperatively with a halo vest. The follow-up period ranged from 3 to 28 months and provided a 100% fusion rate with no complications related to plating or nonunion. Our initial experience indicates that anterior C2-C3 interbody bone fusion and Caspar plate fixation is a suitable treatment option for patients with complex hangman's fractures who are not successfully managed nonoperatively.

  3. Educational Inequalities in Post-Hip Fracture Mortality: A NOREPOS Study.

    Science.gov (United States)

    Omsland, Tone K; Eisman, John A; Naess, Øyvind; Center, Jacqueline R; Gjesdal, Clara G; Tell, Grethe S; Emaus, Nina; Meyer, Haakon E; Søgaard, Anne Johanne; Holvik, Kristin; Schei, Berit; Forsmo, Siri; Magnus, Jeanette H

    2015-12-01

    Hip fractures are associated with high excess mortality. Education is an important determinant of health, but little is known about educational inequalities in post-hip fracture mortality. Our objective was to investigate educational inequalities in post-hip fracture mortality and to examine whether comorbidity or family composition could explain any association. We conducted a register-based population study of Norwegians aged 50 years and older from 2002 to 2010. We measured total mortality according to educational attainment in 56,269 hip fracture patients (NORHip) and in the general Norwegian population. Both absolute and relative educational inequalities in mortality in people with and without hip fracture were compared. There was an educational gradient in post-hip fracture mortality in both sexes. Compared with those with primary education only, the age-adjusted relative risk (RR) of mortality in hip fracture patients with tertiary education was 0.82 (95% confidence interval [CI] 0.77-0.87) in men and 0.79 (95% CI 0.75-0.84) in women. Additional adjustments for Charlson comorbidity index, marital status, and number of children did not materially change the estimates. Regardless of educational attainment, the 1-year age-adjusted mortality was three- to fivefold higher in hip fracture patients compared with peers in the general population without fracture. The absolute differences in 1-year mortality according to educational attainment were considerably larger in hip fracture patients than in the population without hip fracture. Absolute educational inequalities in mortality were higher after hip fracture compared with the general population without hip fracture and were not mediated by comorbidity or family composition. Investigation of other possible mediating factors might help to identify new targets for interventions, based on lower educational attainment, to reduce post-hip fracture mortality.

  4. Timing of internal fixation of femoral neck fractures. A systematic review and meta-analysis of the final outcome.

    Science.gov (United States)

    Papakostidis, Costas; Panagiotopoulos, Andreas; Piccioli, Andrea; Giannoudis, Peter V

    2015-03-01

    The aim of the present study was to evaluate the effect of timing of internal fixation of intracapsular fractures of the neck of femur on the development of late complications, particularly osteonecrosis of femoral head (ONFH) and non-union. We undertook a systematic review of the literature adhering to the PRISMA guidelines. There were 7 eligible reports for the final analysis. The methodological quality of component studies was assessed with the Coleman Methodology Score (CMS). Each included study was assigned a score independently by the two reviewers. The final score of each individual study constituted the average value of the scores given by the two reviewers. The agreement between the two assessors was tested with intraclass correlation coefficient (ICC). The CMS ranged from 37 to 64 within component studies (mean: 46.5, SD: 10.8, median: 41). The ICC was 0.94 (95% CI: 0.69-0.99), implying a nearly perfect agreement between the two assessors. Based on the available data regarding the timing of operative fixation of the femoral neck fractures, 4 discreet pairs of comparison groups could be created: (1) fractures fixed within 6h from injury versus fractures fixed after 6h from injury; (2) fractures fixed within 12h versus after 12h; (3) fractures fixed within 24h versus after 24h; and (4) fractures fixed within 6h versus after 24h. Outcome measures were analyzed within each one of the above pairs of treatment groups. The following subgroups analyses were a priori decided: (1) initial fracture displacement (displaced vs. undisplaced fractures); (2) fixation method (cannulated screws vs. sliding hip screw); (3) quality of reduction (anatomic vs non-anatomic reduction). This study failed to prove any essential association between timing of NOF fracture internal fixation and incidence of AVN. With respect to non-union though, it indicated that delay of internal fixation of more than 24h could increase substantially the odds of non-union. Copyright © 2015 Elsevier

  5. A long-term follow-up of 221 hip fracture patients in southeastern Finland: analysis of survival and prior or subsequent fractures.

    Science.gov (United States)

    Lüthje, Peter; Helkamaa, Teemu; Kaukonen, Juha-Pekka; Nurmi-Lüthje, Ilona; Kataja, Matti

    2012-01-01

    To analyze the type and effect of prior and subsequent fractures in a hip fracture cohort. Hip fracture patients (n=221) were followed for a mean of 8 years and all prior and subsequent fractures were studied. Incidence of the first fracture and subsequent fractures according to sex, age group, and time between the first and the index hip fracture were measured. The absolute fracture risk was measured in the study subjects and in the age groups hip fracture patients had sustained previous fractures. In men, these were mostly ankle or hip fractures, and in women, wrist fractures. Of the subjects, 24% suffered a subsequent fracture, which in both sexes was usually a second hip fracture. At the end of the 8-year follow-up, 74% of the patients had died. The observed absolute fracture risk was 7% at one year and 24% at 5 years. In women, excess mortality was lowest during the first 4.8 years after the index hip fracture among patients with one fracture. However, it was highest among women with two fractures. In men, excess mortality was lowest among those with two fractures and highest among those with ≥3 fractures. There were no differences between the genders in sustaining subsequent fractures. The fracture risk subsequent to hip fracture was similar in both genders. Patients with prior hip fractures had the worst survival rate. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Planning acetabular fracture reduction using patient-specific multibody simulation of the hip

    Science.gov (United States)

    Oliveri, Hadrien; Boudissa, Mehdi; Tonetti, Jerome; Chabanas, Matthieu

    2017-03-01

    Acetabular fractures are a challenge in orthopedic surgery. Computer-aided solutions were proposed to segment bone fragments, simulate the fracture reduction or design the osteosynthesis fixation plates. This paper addresses the simulation part, which is usually carried out by freely moving bone fragments with six degrees of freedom to reproduce the pre-fracture state. Instead we propose a different paradigm, closer to actual surgeon's requirements: to simulate the surgical procedure itself rather than the desired result. A simple, patient-specific, biomechanical multibody model is proposed, integrating the main ligaments and muscles of the hip joint while accounting for contacts between bone fragments. Main surgical tools and actions can be simulated, such as clamps, Schanz screws or traction of the femur. Simulations are computed interactively, which enables clinicians to evaluate different strategies for an optimal surgical planning. Six retrospective cases were studied, with simple and complex fracture patterns. After interactively building the models from preoperative CT, gestures from the surgical reports were reproduced. Results of the simulations could then be compared with postoperative CT data. A qualitative study shows the model behavior is excellent and the simulated reductions fit the observed data. A more quantitative analysis is currently being completed. Two cases are particularly significant, for which the surgical reduction actually failed. Simulations show it was indeed not possible to reduce these fractures with the chosen approach. Had our simulator being used, a better planning may have avoided a second surgery to these patients.

  7. Fracture of the ceramic epiphysis in hip arthroplasty.

    Science.gov (United States)

    Toni, A; Terzi, S; Sudanese, A; Zappoli, F A; Giunti, A

    1996-01-01

    Between November 1985 and October 1993, a total of 694 ceramic-ceramic hip arthroplasties were implanted; up until 1987 the alumina used in the first 82 cases was Ostalox, produced by IMEC of Caravaggio, characterized by poor control of the size of the crystals; after 1987 Biolox alumina of the Feldmhule company was used in 612 cases. Fracture of the ceramic head occurred in 2 cases; in both patients ceramic was of the Ostalox type, meaning a 2.4% incidence of fracture; up until the present none of the 612 Biolox heads has presented this complication.

  8. Machine Learning Principles Can Improve Hip Fracture Prediction

    DEFF Research Database (Denmark)

    Kruse, Christian; Eiken, Pia; Vestergaard, Peter

    2017-01-01

    Apply machine learning principles to predict hip fractures and estimate predictor importance in Dual-energy X-ray absorptiometry (DXA)-scanned men and women. Dual-energy X-ray absorptiometry data from two Danish regions between 1996 and 2006 were combined with national Danish patient data.......89 [0.82; 0.95], but with poor calibration in higher probabilities. A ten predictor subset (BMD, biochemical cholesterol and liver function tests, penicillin use and osteoarthritis diagnoses) achieved a test AUC of 0.86 [0.78; 0.94] using an "xgbTree" model. Machine learning can improve hip fracture...... prediction beyond logistic regression using ensemble models. Compiling data from international cohorts of longer follow-up and performing similar machine learning procedures has the potential to further improve discrimination and calibration....

  9. Four quadrant parallel peripheral screw fixation for displaced femoral neck fractures in elderly patients

    Directory of Open Access Journals (Sweden)

    Bhava RJ Satish

    2013-01-01

    Conclusion: Closed reduction and cannulated cancellous screw fixation gives satisfactory functional results in large group of elderly patients. The four quadrant parallel peripheral (FQPP screw fixation technique gives good stability, allows controlled collapse, avoids fixation failure and achieves predictable bone healing in displaced femoral neck fracture in patients ≥50 years of age.

  10. Modeling climate effects on hip fracture rate by the multivariate GARCH model in Montreal region, Canada

    Science.gov (United States)

    Modarres, Reza; Ouarda, Taha B. M. J.; Vanasse, Alain; Orzanco, Maria Gabriela; Gosselin, Pierre

    2014-07-01

    Changes in extreme meteorological variables and the demographic shift towards an older population have made it important to investigate the association of climate variables and hip fracture by advanced methods in order to determine the climate variables that most affect hip fracture incidence. The nonlinear autoregressive moving average with exogenous variable-generalized autoregressive conditional heteroscedasticity (ARMA X-GARCH) and multivariate GARCH (MGARCH) time series approaches were applied to investigate the nonlinear association between hip fracture rate in female and male patients aged 40-74 and 75+ years and climate variables in the period of 1993-2004, in Montreal, Canada. The models describe 50-56 % of daily variation in hip fracture rate and identify snow depth, air temperature, day length and air pressure as the influencing variables on the time-varying mean and variance of the hip fracture rate. The conditional covariance between climate variables and hip fracture rate is increasing exponentially, showing that the effect of climate variables on hip fracture rate is most acute when rates are high and climate conditions are at their worst. In Montreal, climate variables, particularly snow depth and air temperature, appear to be important predictors of hip fracture incidence. The association of climate variables and hip fracture does not seem to change linearly with time, but increases exponentially under harsh climate conditions. The results of this study can be used to provide an adaptive climate-related public health program and ti guide allocation of services for avoiding hip fracture risk.

  11. The role of external fixation and emergency fracture management in bovine orthopedics.

    Science.gov (United States)

    Adams, S B

    1985-03-01

    External fixation is a very useful method of treating selected fractures in cattle. The economics of therapy and the availability of the techniques to all veterinarians will continue to make external fixation the most frequently used method of fracture repair in cattle.

  12. Plate fixation of paediatric fractures of the distal tibia and fibula.

    Science.gov (United States)

    He, Bingshu; Wang, Jun

    2012-10-01

    The role of surgery in the management of paediatric long-bone shaft fractures remains a matter of debate. We present a series of paediatric patients with unstable fractures of the distal tibia and fibula, treated with titanium plate fixation. Excellent results were obtained after plate fixation.

  13. Clinical Analysis of Internal Fixation Treatment of Intra-articular Calcaneal Fractures with Titanium Plate.

    Science.gov (United States)

    Chen, Xiao-Dong; Zhang, Chang-Chun; Li, Zhao-Cheng; Zhang, Heng; Zhou, Xin-She; Deng, Min

    2015-05-01

    To explore the clinical effect of internal fixation treatment of intra-articular calcaneal fractures with titanium plate, we used open reduction and internal fixation with titanium plate to 48 treated feet from 42 patients with intra-articular calcaneal fractures. The efficacy of surgical treatment was evaluated based on assessment of pain, function, and line of force aspects according to the American Orthopedic Foot and Ankle Society scoring system. Our data show that internal fixation with titanium plate is an effective treatment for calcaneal fractures. It provides satisfactory reduction, reliable fixation, and early rehabilitation.

  14. Dementia and delirium, the outcomes in elderly hip fracture patients

    Science.gov (United States)

    Mosk, Christina A; Mus, Marnix; Vroemen, Jos PAM; van der Ploeg, Tjeerd; Vos, Dagmar I; Elmans, Leon HGJ; van der Laan, Lijckle

    2017-01-01

    Background Delirium in hip fractured patients is a frequent complication. Dementia is an important risk factor for delirium and is common in frail elderly. This study aimed to extend the previous knowledge on risk factors for delirium and the consequences. Special attention was given to patients with dementia and delirium. Methods This is a retrospective cohort study performed in the Amphia Hospital, Breda, the Netherlands. A full electronic patient file system (Hyperspace Version IU4: Epic, Inc., Verona, WI, USA) was used to assess data between January 2014 and September 2015. All patients presented were aged ≥70 years with a hip fracture, who underwent surgery with osteosynthesis or arthroplasty. Patients were excluded in case of a pathological or a periprosthetic hip fracture, multiple traumatic injuries, and high-energy trauma. Patient and surgical characteristics were documented. Postoperative outcomes were noted. Delirium was screened using Delirium Observation Screening Scale and dementia was assessed from medical notes. Results Of a total of 566 included patients, 75% were females. The median age was 84 years (interquartile range: 9). Delirium was observed in 35%. Significant risk factors for delirium were a high American Society of Anesthesiology score, delirium in medical history, functional dependency, preoperative institutionalization, low hemoglobin level, and high amount of blood transfusion. Delirium was correlated with a longer hospital stay (P=0.001), increased association with complications (PPatients with dementia (N=168) had a higher delirium rate (57.7%, Ppatients with (34.0%) and without dementia (26.3%). Conclusion Elderly patients with a hip fracture are vulnerable for delirium, especially when the patient has dementia. Patients who underwent an episode of delirium were at increased risk for adverse outcomes. PMID:28331300

  15. Changing trends in the epidemiology of hip fracture in Spain

    Science.gov (United States)

    Azagra, R.; López-Expósito, F.; Martin-Sánchez, JC.; Aguyé, A.; Moreno, N.; Cooper, C.; Díez-Pérez, A.; Dennison, EM.

    2016-01-01

    Summary Temporal trends in hip fracture incidence have recently been reported in some developed countries. Such data in Spain has previously been incomplete; this study reports the stratified incidence of hip fractures in people over 65 in Spain during the last 14 years. Introduction The main objective is to establish whether temporal trends in hip fracture incidence in Spain exist. Methods Ecological study with data from hospital discharges nationwide. The study includes patients aged ≥ 65 years during a 14-year period (1997-2010). The analysis compares two periods of four years: 1997-2000 (P1) and 2007-2010 (P2). Results There were 119,857 fractures in men and 415,421 in women. Comparing periods (P1 vs P2), over ten years the crude incidence rate/100,000 inhabitant/year increased an average of 2.3%/year in men and 1.4% in women. After adjustment, the rate increased an average of 0.4%/year in men (p<0.0001), but decreased 0.2%/year in women (p<0.0001). In men younger than 85, the decrease was not significant except in 70-74 years and from 80 years the adjusted rate increases significantly (p<0.0001). In women under 80 years of age, the decrease in adjusted rate was significant, there was no change in 80-84 years and the adjusted rate increased significantly in individuals 85 years and older (p<0.0001). Mortality rates declined by 22% in both sexes and the index of overaging population rises 30.1% in men and 25.2% in women. Conclusions This study supports other international studies by showing changes in the incidence of hip fractures after age-population adjustment, which denotes a decrease in the younger age groups and among women and shows an increase in both groups over 85 years. The increase in the crude incidence rate of hip fracture in Spain reflects changes in population structure. PMID:24322478

  16. Dementia and delirium, the outcomes in elderly hip fracture patients.

    Science.gov (United States)

    Mosk, Christina A; Mus, Marnix; Vroemen, Jos Pam; van der Ploeg, Tjeerd; Vos, Dagmar I; Elmans, Leon Hgj; van der Laan, Lijckle

    2017-01-01

    Delirium in hip fractured patients is a frequent complication. Dementia is an important risk factor for delirium and is common in frail elderly. This study aimed to extend the previous knowledge on risk factors for delirium and the consequences. Special attention was given to patients with dementia and delirium. This is a retrospective cohort study performed in the Amphia Hospital, Breda, the Netherlands. A full electronic patient file system (Hyperspace Version IU4: Epic, Inc., Verona, WI, USA) was used to assess data between January 2014 and September 2015. All patients presented were aged ≥70 years with a hip fracture, who underwent surgery with osteosynthesis or arthroplasty. Patients were excluded in case of a pathological or a periprosthetic hip fracture, multiple traumatic injuries, and high-energy trauma. Patient and surgical characteristics were documented. Postoperative outcomes were noted. Delirium was screened using Delirium Observation Screening Scale and dementia was assessed from medical notes. Of a total of 566 included patients, 75% were females. The median age was 84 years (interquartile range: 9). Delirium was observed in 35%. Significant risk factors for delirium were a high American Society of Anesthesiology score, delirium in medical history, functional dependency, preoperative institutionalization, low hemoglobin level, and high amount of blood transfusion. Delirium was correlated with a longer hospital stay (P=0.001), increased association with complications (Pdelirium rate (57.7%, Pdelirium, especially when the patient has dementia. Patients who underwent an episode of delirium were at increased risk for adverse outcomes.

  17. Use of DXA-Based Structural Engineering Models of the Proximal Femur to Discriminate Hip Fracture

    Science.gov (United States)

    Yang, Lang; Peel, Nicola; Clowes, Jackie A; McCloskey, Eugene V; Eastell, Richard

    2011-01-01

    Several DXA-based structural engineering models (SEMs) of the proximal femur have been developed to estimate stress caused by sideway falls. Their usefulness in discriminating hip fracture has not yet been established and we therefore evaluated these models. The hip DXA scans of 51 postmenopausal women with hip fracture (30 femoral neck, 17 trochanteric, and 4 unspecified) and 153 age-, height-, and weight-matched controls were reanalyzed using a special version of Hologic’s software that produced a pixel-by-pixel BMD map. For each map, a curved-beam, a curved composite-beam, and a finite element model were generated to calculate stress within the bone when falling sideways. An index of fracture risk (IFR) was defined over the femoral neck, trochanter, and total hip as the stress divided by the yield stress at each pixel and averaged over the regions of interest. Hip structure analysis (HSA) was also performed using Hologic APEX analysis software. Hip BMD and almost all parameters derived from HSA and SEM were discriminators of hip fracture on their own because their ORs were significantly >1. Because of the high correlation of total hip BMD to HSA and SEM-derived parameters, only the bone width discriminated hip fracture independently from total hip BMD. Judged by the area under the receiver operating characteristics curve, the trochanteric IFR derived from the finite element model was significant better than total hip BMD alone and similar to the total hip BMD plus bone width in discriminating all hip fracture and femoral neck fracture. No index was better than total hip BMD for discriminating trochanteric fractures. In conclusion, the finite element model has the potential to replace hip BMD in discriminating hip fractures. PMID:18767924

  18. High reliability of an algorithm for choice of implants in hip fracture patients

    DEFF Research Database (Denmark)

    Palm, Henrik; Posner, Eva; Ahler-Toftehøj, Hans-Ulrik;

    2013-01-01

    Hip fracture treatment is controversial, with high complication rates. An algorithm for hip fracture surgery has shown reduced reoperation rates, but choice of implant is based on the commonly used fracture classifications, which were previously evaluated to be unreliable. The purpose of this study...... was to investigate the reliability of the algorithm....

  19. The incidence of hip fractures in Norway -accuracy of the national Norwegian patient registry

    DEFF Research Database (Denmark)

    Høiberg, Mikkel; Gram, Jeppe; Hermann, Pernille;

    2014-01-01

    Background: Hip fractures incur the greatest medical costs of any fracture. Valid epidemiological data are important to monitor for time-dependent changes. In Norway, hip fractures are registered in the Norwegian Patient Registry (NPR), but no published national validation exists. The aim...

  20. Intertrochanteric Fracture After Hip Resurfacing Arthroplasty Managed with a Reconstruction Nail

    Directory of Open Access Journals (Sweden)

    Jason Chow

    2013-12-01

    Full Text Available Periprosthetic fractures after hip resurfacings are rare occurrences that can pose a challenge to orthopaedic surgeons. With hip resurfacings becoming more common, the prevalence of these fractures is likely to increase because these patients are usually younger and more active. We report a case of traumatic periprosthetic proximal femur fracture treated with a reconstruction intramedullary nail technique.

  1. Stabilization of unstable pelvic fractures with a novel internal-external fixator

    Institute of Scientific and Technical Information of China (English)

    JIANG Zan-li; Gary Chen

    2011-01-01

    An internal-external fixator for stabilization in three cases with unstable pelvic fractures were reported.Compared with external fixation,the internal-external fixator,which is placed in the subcutaneous layer,decreased the risk of pin-track infection,pin site pain,and bowel obstruction; meanwhile,it had the advantage of external fixation:it was easy to apply,controlled damage,and resulted in minimal injury.

  2. Dementia and delirium, the outcomes in elderly hip fracture patients

    Directory of Open Access Journals (Sweden)

    Mosk CA

    2017-03-01

    Full Text Available Christina A Mosk,1 Marnix Mus,1 Jos PAM Vroemen,1 Tjeerd van der Ploeg,2 Dagmar I Vos,1 Leon HGJ Elmans,3 Lijckle van der Laan1 1Department of Surgery, Amphia Hospital, Breda, 2Department of Public Health, Erasmus MC–University Medical Center, Rotterdam, 3Department of Orthopedic Surgery, Amphia Hospital, Breda, the Netherlands Background: Delirium in hip fractured patients is a frequent complication. Dementia is an important risk factor for delirium and is common in frail elderly. This study aimed to extend the previous knowledge on risk factors for delirium and the consequences. Special attention was given to patients with dementia and delirium.Methods: This is a retrospective cohort study performed in the Amphia Hospital, Breda, the Netherlands. A full electronic patient file system (Hyperspace Version IU4: Epic, Inc., Verona, WI, USA was used to assess data between January 2014 and September 2015. All patients presented were aged ≥70 years with a hip fracture, who underwent surgery with osteosynthesis or arthroplasty. Patients were excluded in case of a pathological or a periprosthetic hip fracture, multiple traumatic injuries, and high-energy trauma. Patient and surgical characteristics were documented. Postoperative outcomes were noted. Delirium was screened using Delirium Observation Screening Scale and dementia was assessed from medical notes.Results: Of a total of 566 included patients, 75% were females. The median age was 84 years (interquartile range: 9. Delirium was observed in 35%. Significant risk factors for delirium were a high American Society of Anesthesiology score, delirium in medical history, functional dependency, preoperative institutionalization, low hemoglobin level, and high amount of blood transfusion. Delirium was correlated with a longer hospital stay (P=0.001, increased association with complications (P<0.001, institutionalization (P<0.001, and 6-month mortality (P<0.001. Patients with dementia (N=168 had a

  3. Can Hip Fracture Prediction in Women be Estimated beyond Bone Mineral Density Measurement Alone?

    Science.gov (United States)

    Geusens, Piet; van Geel, Tineke; van den Bergh, Joop

    2010-01-01

    The etiology of hip fractures is multifactorial and includes bone and fall-related factors. Low bone mineral density (BMD) and BMD-related and BMD-independent geometric components of bone strength, evaluated by hip strength analysis (HSA) and finite element analysis analyses on dual-energy X-ray absorptiometry (DXA) images, and ultrasound parameters are related to the presence and incidence of hip fracture. In addition, clinical risk factors contribute to the risk of hip fractures, independent of BMD. They are included in the fracture risk assessment tool (FRAX) case finding algorithm to estimate in the individual patient the 10-year risk of hip fracture, with and without BMD. Fall risks are not included in FRAX, but are included in other case finding tools, such as the Garvan algorithm, to predict the 5- and 10-year hip fracture risk. Hormones, cytokines, growth factors, markers of bone resorption and genetic background have been related to hip fracture risk. Vitamin D deficiency is endemic worldwide and low serum levels of 25-hydroxyvitamin D [25(OH)D] predict hip fracture risk. In the context of hip fracture prevention calculation of absolute fracture risk using clinical risks, BMD, bone geometry and fall-related risks is feasible, but needs further refinement by integrating bone and fall-related risk factors into a single case finding algorithm for clinical use. PMID:22870438

  4. Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation

    Directory of Open Access Journals (Sweden)

    Katonis Pavlos G

    2009-05-01

    Full Text Available Abstract Background Lag screw cut-out failure following fixation of unstable intertrochanteric fractures in osteoporotic bone remains an unsolved challenge. This study tested if resistance to cut-out failure can be improved by using a dual lag screw implant in place of a single lag screw implant. Migration behavior and cut-out resistance of a single and a dual lag screw implant were comparatively evaluated in surrogate specimens using an established laboratory model of hip screw cut-out failure. Methods Five dual lag screw implants (Endovis, Citieffe and five single lag screw implants (DHS, Synthes were tested in the Hip Implant Performance Simulator (HIPS of the Legacy Biomechanics Laboratory. This model simulated osteoporotic bone, an unstable fracture, and biaxial rocking motion representative of hip loading during normal gait. All constructs were loaded up to 20,000 cycles of 1.45 kN peak magnitude under biaxial rocking motion. The migration kinematics was continuously monitored with 6-degrees of freedom motion tracking system and the number of cycles to implant cut-out was recorded. Results The dual lag screw implant exhibited significantly less migration and sustained more loading cycles in comparison to the DHS single lag screw. All DHS constructs failed before 20,000 cycles, on average at 6,638 ± 2,837 cycles either by cut-out or permanent screw bending. At failure, DHS constructs exhibited 10.8 ± 2.3° varus collapse and 15.5 ± 9.5° rotation around the lag screw axis. Four out of five dual screws constructs sustained 20,000 loading cycles. One dual screw specimens sustained cut-out by medial migration of the distal screw after 10,054 cycles. At test end, varus collapse and neck rotation in dual screws implants advanced to 3.7 ± 1.7° and 1.6 ± 1.0°, respectively. Conclusion The single and double lag screw implants demonstrated a significantly different migration resistance in surrogate specimens under gait loading simulation with

  5. Surgical treatment of zygomatic bone fracture using two points fixation versus three point fixation-a randomised prospective clinical trial

    Directory of Open Access Journals (Sweden)

    Rana Majeed

    2012-04-01

    Full Text Available Abstract Background The zygoma plays an important role in the facial contour for both cosmetic and functional reasons; therefore zygomatic bone injuries should be properly diagnosed and adequately treated. Comparison of various surgical approaches and their complications can only be done objectively using outcome measurements which in turn require protocol management and long-term follow up. The preference for open reduction and internal fixation of zygomatic fractures at three points has continued to grow in response to observations of inadequate results from two point and one point fixation techniques. The objectives of this study were to compare the efficacy of zygomatic bone after treatment with ORIF using 2 point fixation and ORIF using 3 point fixation and compare the outcome of two procedures. Methods 100 patients were randomly divided equally into two groups. In group A, 50 patients were treated by ORIF using two point fixation by miniplates and in group B, 50 patients were treated by ORIF using three point fixation by miniplates. They were evaluated for their complications during and after surgery with their advantages and disadvantages and the difference between the two groups was observed. Results A total of 100 fractures were sustained. We found that postoperative complication like decreased malar height and vertical dystopia was more common in those patients who were treated by two point fixation than those who were treated with three point fixation. Conclusions Based on this study open reduction and internal fixation using three point fixation by miniplates is the best available method for the treatment zygomatic bone fractures.

  6. Inflammatory markers and risk of hip fracture in older white women: the study of osteoporotic fractures.

    Science.gov (United States)

    Barbour, Kamil E; Lui, Li-Yung; Ensrud, Kristine E; Hillier, Teresa A; LeBlanc, Erin S; Ing, Steven W; Hochberg, Marc C; Cauley, Jane A

    2014-09-01

    Hip fractures are the most devastating consequence of osteoporosis and impact 1 in 6 white women leading to a two- to threefold increased mortality risk in the first year. Despite evidence of inflammatory markers in the pathogenesis of osteoporosis, few studies have examined their effect on hip fracture. To determine if high levels of inflammation increase hip fracture risk and to explore mediation pathways, a case-cohort design nested in a cohort of 4709 white women from the Study of Osteoporotic Fractures was used. A random sample of 1171 women was selected as the subcohort (mean age 80.1 ± 4.2 years) plus the first 300 women with incident hip fracture. Inflammatory markers interleukin-6 (IL-6) and soluble receptors (SR) for IL-6 (IL-6 SR) and tumor necrosis factor (TNF SR1 and TNF SR2) were measured, and participants were followed for a median (interquartile range) of 6.3 (3.7, 6.9) years. In multivariable models, the hazard ratio (HR) of hip fracture for women in the highest inflammatory marker level (quartile 4) was 1.64 (95% confidence interval [CI], 1.09-2.48, p trend = 0.03) for IL-6 and 2.05 (95% CI, 1.35-3.12, p trend hip fracture was 1.51 (95% CI, 1.07-2.14) and 1.42 (95% CI, 0.87-2.31) compared with women with zero to one marker(s) in the highest quartile (p trend = 0.03). After individually adjusting for seven potential mediators, cystatin-C (a biomarker of renal function) and bone mineral density (BMD) attenuated HRs among women with the highest inflammatory burden by 64% and 50%, respectively, suggesting a potential mediating role. Older white women with high inflammatory burden are at increased risk of hip fracture in part due to poor renal function and low BMD. © 2014 American Society for Bone and Mineral Research.

  7. Hollow-Bone-Graft Dynamic Hip Screw Can Fix and Promote Bone Union after Femoral Neck Fracture: an Experimental Research

    Directory of Open Access Journals (Sweden)

    Jia-zuo SHEN, Jian-fei YAO, Da-sheng LIN, Ke-jian LIAN, Zhen-qi DING, Bin LIN, Zhi-min GUO, Ming-hua ZHANG, Qiang LI, Lin LI, Peng QI

    2012-01-01

    Full Text Available Background: Delayed bone union, nonunion or osteonecrosis often occur after femoral neck fractures in young adults. Secondary bone healing requires strong internal fixation, intramedullary pressure reduction and early functional exercise.Objective: To compare bone healing of femoral neck fractures treated with hollow-bone-graft dynamic hip screws (Hb-DHS and standard dynamic hip screws (DHS in an animal model.Design: Testing of specifically designed fixation devices in a pig animal model.Interventions/Methods: We designed Hb-DHS and DHS devices appropriate to the femoral neck and head of experimental animals and used them in eight pigs (4-month-old, male or female, 30-40 kg/each. Under anesthesia, we induced medium neck type, Garden III type femoral neck fractures in each pig with fracture gaps of 0.5 mm and then fixed each left femur with Hb-DHS and each right femur with DHS. We assessed the animals radiographically and by postmortem visual appraisal of evidence of bone healing 8 and 16 weeks postoperatively.Results: There were significant differences in radiographic and general findings between the Hb-DHS and DHS groups at weeks 8 and 16 postoperatively. We found statistically significant differences between the Hb-DHS and DHS groups in bone healing scores, trabecular bone volume percentage and bone mineral density as assessed on plain radiographs and computed tomography images (P < 0.05. There were also significant differences between the Hb-DHS and DHS groups in postmortem visually assessed indicators of bone healing at both 8 and 16 weeks postoperatively.Conclusions: The Hb-DHS device promotes femoral neck bone union, stimulates trabecular bone formation, increases BMD and has advantages over DHS for internal fixation of femoral neck fractures. This animal experiment will contribute to developing optimal treatment for femoral neck fractures in young adults.

  8. A STUDY OF PRIMARY CEMENTED BIPOLAR HEMIARTHROPLASTY OF HIP IN ELDERLY PATIENTS WITH OSTEOPOROTIC, UNSTABLE INTERTROCHANTERIC FRACTURE

    Directory of Open Access Journals (Sweden)

    Maheshwar

    2015-08-01

    Full Text Available BACKGROUND: Intertrochanteric fractures are a major cause of morbidity and mortality in geriatric population. Osteoporosis contributes significantly to the comminution and instability in such fractures. Internal fixations in unstable intertrochanteric fractures are a ssociated with high rates of implant failures and gross restriction of hip movements. This study was undertaken to evaluate the efficacy of cemented bipolar hemiart h roplasty in elderly patients with osteoporotic, unstable intertrochanteric fractures. PATIE NTS AND METHODS: 52 patients aged above 60 years with unstable, comminuted intertrochanteric fractures with Singh’s index < 4 were operated with primary cemented bipolar hemireplacement arthroplasty. All the patients were mobilized early with full weight b earing in the post - operative period as permitted. 50 patients were evaluated for the functional outcome with Harris Hip score. RESULTS: The average age of patients was 65 years with female predominance (64%. Left side (56% was commonly involved and the c ommonest mode of injury was due to a trivial fall at home. Hypertension (30% was the commonest co - morbid condition. Limb shortening was the commonest complication (8%. The mean ± S.D. of the Harris Hip score was 85.6 ± 10.59 with a range from 56 to 96. Resul ts were excellent in 62%, good in 22%, fair in 12% and poor in 4% of cases. CONCLUSION: Elderly osteoporotic patients with comminuted, unstable intertrochanteric fractures have an increased prevalence of unsatisfactory functional results with conventional internal fixation devices. Primary cemented bipolar hemiarthroplasty with anatomical reconstruction of the trochanters allows early mobilization, improved functional outcome with relatively low incidence of associated complications.

  9. Survival times of patients with a first hip fracture with and without subsequent major long-bone fractures.

    Science.gov (United States)

    Angthong, Chayanin; Angthong, Wirana; Harnroongroj, Thos; Naito, Masatoshi; Harnroongroj, Thossart

    2013-01-01

    Survival rates are poorer after a second hip fracture than after a first hip fracture. Previous survival studies have included in-hospital mortality. Excluding in-hospital deaths from the analysis allows survival times to be evaluated in community-based patients. There is still a lack of data regarding the effects of subsequent fractures on survival times after hospital discharge following an initial hip fracture. This study compared the survival times of community-dwelling patients with hip fracture who had or did not have a subsequent major long-bone fracture. Hazard ratios and risk factors for subsequent fractures and mortality rates with and without subsequent fractures were calculated. Of 844 patients with hip fracture from 2000 through 2008, 71 had a subsequent major long-bone fracture and 773 did not. Patients who died of other causes, such as perioperative complications, during hospitalization were excluded. Such exclusion allowed us to determine the effect of subsequent fracture on the survival of community-dwelling individuals after hospital discharge or after the time of the fracture if they did not need hospitalization. Demographic data, causes of death, and mortality rates were recorded. Differences in mortality rates between the patient groups and hazard ratios were calculated. Mortality rates during the first year and from 1 to 5 years after the most recent fracture were 5.6% and 1.4%, respectively, in patients with subsequent fractures, and 4.7% and 1.4%, respectively, in patients without subsequent fractures. These rates did not differ significantly between the groups. Cox regression analysis and calculation of hazard ratios did not show significant differences between patients with subsequent fractures and those without. On univariate and multivariate analyses, age fracture. This study found that survival times did not differ significantly between patients with and without subsequent major long-bone fractures after hip fracture. Therefore, all

  10. Association between timing of zoledronic acid infusion and hip fracture healing

    DEFF Research Database (Denmark)

    Colón-Emeric, C; Nordsletten, L; Olson, S

    2010-01-01

    Patients in the Health Outcomes and Reduced Incidence with Zoledronic Acid Once Yearly (HORIZON) Recurrent Fracture Trial were assessed for evidence of delayed hip fracture healing. No association was observed between zoledronic acid (ZOL) and delayed healing. We conclude that ZOL has no clinically...... evident effect on fracture healing, even when the drug is infused in the immediate postoperative period. INTRODUCTION: Intravenous zoledronic acid 5 mg (ZOL) given after a hip fracture reduces secondary fracture rates and mortality. It has been postulated that bisphosphonates may affect healing if given...... soon after a fracture. We sought to determine whether the timing of ZOL infusion affected the risk of delayed hip fracture healing. METHODS: In the HORIZON Recurrent Fracture Trial, patients were randomized within 90 days of a low-trauma hip fracture to receive either once-yearly ZOL (n¿=¿1...

  11. The risk factors that effect the prognosis in fractures of the hip

    OpenAIRE

    Ozturk, Irfan

    2004-01-01

    There is still some controversy and problems about the treatment of hip fractures in elderly people. In addition to success of surgical technique, low postoperative morbidity and mortality rates also have to be the aim of the therapy. In elderly people whose hips are fractured, there is a high rate of postoperative mortality and medical problems. For this reason preoperative evaluation of hip fractured patients must be well recognized. There are so many "risk evaluation schedules" present in ...

  12. The risk factors that effect the prognosis in fractures of the hip

    OpenAIRE

    Ozturk, Irfan

    2004-01-01

    There is still some controversy and problems about the treatment of hip fractures in elderly people. In addition to success of surgical technique, low postoperative morbidity and mortality rates also have to be the aim of the therapy. In elderly people whose hips are fractured, there is a high rate of postoperative mortality and medical problems. For this reason preoperative evaluation of hip fractured patients must be well recognized. There are so many "risk evaluation schedules" p...

  13. Hip fracture epidemiological trends, outcomes, and risk factors, 1970–2009

    Directory of Open Access Journals (Sweden)

    Ray Marks

    2009-12-01

    Full Text Available Ray MarksCity University of New York and Columbia University, New York, NY, USAAbstract: Hip fractures – which commonly lead to premature death, high rates of morbidity, or reduced life quality – have been the target of a voluminous amount of research for many years. But has the lifetime risk of incurring a hip fracture decreased sufficiently over the last decade or are high numbers of incident cases continuing to prevail, despite a large body of knowledge and a variety of contemporary preventive and refined surgical approaches? This review examines the extensive hip fracture literature published in the English language between 1980 and 2009 concerning hip fracture prevalence trends, and injury mechanisms. It also highlights the contemporary data concerning the personal and economic impact of the injury, plus potentially remediable risk factors underpinning the injury and ensuing disability. The goal was to examine if there is a continuing need to elucidate upon intervention points that might minimize the risk of incurring a hip fracture and its attendant consequences. Based on this information, it appears hip fractures remain a serious global health issue, despite some declines in the incidence rate of hip fractures among some women. Research also shows widespread regional, ethnic and diagnostic variations in hip fracture incidence trends. Key determinants of hip fractures include age, osteoporosis, and falls, but some determinants such as socioeconomic status, have not been well explored. It is concluded that while more research is needed, well-designed primary, secondary, and tertiary preventive efforts applied in both affluent as well as developing countries are desirable to reduce the present and future burden associated with hip fracture injuries. In this context, and in recognition of the considerable variation in manifestation and distribution, as well as risk factors underpinning hip fractures, well-crafted comprehensive, rather

  14. Clinical effects of internal fixation for ulnar styloid fractures associated with distal radius fractures: A matched case-control study.

    Science.gov (United States)

    Sawada, Hideyoshi; Shinohara, Takaaki; Natsume, Tadahiro; Hirata, Hitoshi

    2016-11-01

    Ulnar styloid fractures are often associated with distal radius fractures. However, controversy exists regarding whether to treat ulnar styloid fractures. This study aimed to evaluate clinical effects of internal fixation for ulnar styloid fractures after distal radius fractures were treated with the volar locking plate system. We used prospectively collected data of distal radius fractures. 111 patients were enrolled in this study. A matched case-control study design was used. We selected patients who underwent fixation for ulnar styloid fractures (case group). Three control patients for each patient of the case group were matched on the basis of age, sex, and fracture type of distal radius fractures from among patients who did not undergo fixation for ulnar styloid fractures (control group). The case group included 16 patients (7 men, 9 women; mean age: 52.6 years; classification of ulnar styloid fractures: center, 3; base, 11; and proximal, 2). The control group included 48 patients (15 men, 33 women; mean age: 61.1 years; classification of ulnar styloid fractures: center, 10; base, 31; and proximal, 7). For radiographic examination, the volar tilt angle, radial inclination angle, and ulnar variance length were measured, and the union of ulnar styloid fractures was judged. For clinical examination, the range of motions, grip strength, Hand20 score, and Numeric Rating Scale score were evaluated. There was little correction loss for each radiological parameter of fracture reduction, and these parameters were not significantly different between the groups. The bone-healing rate of ulnar styloid fractures was significantly higher in the case group than in the control group, but the clinical results were not significantly different. We revealed that there was no need to fix ulnar styloid fractures when distal radius fractures were treated via open reduction and internal fixation with a volar locking plate system. Copyright © 2016 The Japanese Orthopaedic Association

  15. Feasibility of Progressive Strength Training Implemented in the Acute Ward after Hip Fracture Surgery

    DEFF Research Database (Denmark)

    Kronborg, Lise; Bandholm, Thomas; Palm, Henrik;

    2014-01-01

    IMPORTANCE: Patients with a hip fracture lose more than 50% knee-extension strength in the fractured limb within one week of surgery. Hence, immediate progressive strength training following hip fracture surgery may be rational, but the feasibility unknown. OBJECTIVE: To examine the feasibility...... of in-hospital progressive strength training implemented in the acute ward following hip fracture surgery, based on pre-specified criteria for feasibility. DESIGN, SETTING AND PATIENTS: A prospective cohort study conducted in an acute orthopedic hip fracture unit at a university hospital. A consecutive...... sample of 36 patients, 18 with a cervical and 18 with a trochanteric hip fracture (27 women and 9 men, mean (SD) age of 79.4 (8.3) years) were included between June and December 2012. INTERVENTION: A daily (on weekdays) program of progressive knee-extension strength training for the fractured limb, using...

  16. Percutaneous Kirschner wire (K-wire) fixation for humerus shaft fractures in children: A treatment concept

    OpenAIRE

    2013-01-01

    Background: Fractures of the humeral shaft are uncommon, representing less than 10 percent of all fractures in children. Humeral shaft fractures in children can be treated by immobilisation alone. A small number of fractures are unable to be reduced adequately or maintained in adequate alignment, and these should be treated surgically. In the present study, Kirschner wires (K-wire) were used to achieve a closed intramedullary fixation of humeral shaft fractures. The objective of this study wa...

  17. Room for improvement in the treatment of hip fractures in Denmark

    DEFF Research Database (Denmark)

    Egerod, Ingrid; Rud, Kirsten; Specht, Kirsten;

    2010-01-01

    INTRODUCTION: Treatment of hip fractures has evolved since the introduction of fast-track surgical programs in the late 1990s. The aim of our study was to describe the quality of treatment and care related to fast-track hip fracture surgery in Denmark by external audit of patient records. MATERIAL...... AND METHODS: This was a national multicenter audit of hospital charts from each hospital treating ≥ 50 hip fracture patients per year (n = 594). RESULTS: The study demonstrated significant variability in treatment and care of patients with hip fractures among the regions of Denmark. Pain management...

  18. A comparison of hip fracture incidence rates among elderly in Sweden by latitude and sunlight exposure.

    Science.gov (United States)

    Nilson, Finn; Moniruzzaman, Syed; Andersson, Ragnar

    2014-03-01

    Research has shown that hip fracture risk increases with latitude; hypothetically due to reduced sunlight exposure and its effect on bone quality. Sweden, with large differences in latitude and UV radiation, is ideal to study in order to analyse the association between latitude and UV radiation on age- and sex-specific hip fracture rates among elderly. Aggregated (2006-2008) age- and sex-specific hip fracture data was obtained for each Swedish municipality as well as the municipality's latitudinal coordinates and aggregated (2006-2008) UV radiation levels. Pearson correlations were calculated between hip fracture incidence rates, latitude and UV radiation. Independent t tests were calculated on tertile-categorized latitudinal data in order to investigate the difference in hip fracture risk between these categories. Statistically significant correlations were seen in all groups between hip fracture incidence rates and latitude as well as UV radiation. The independent t tests showed that this correlation was mainly due to high incidence rates in high latitude municipalities. Statistically significant correlations are seen between hip fracture incidence rates and latitude as well as UV radiation in Sweden and the northern parts of Sweden have an increased risk of hip fractures compared to the middle and southern parts. To our knowledge this is the first study using a national discharge register that shows this relationship and provides a starting point for further research to investigate why populations in northern Sweden have a higher risk of hip fractures compared to other Swedish regions.

  19. A Meta-Analysis for Postoperative Complications in Tibial Plafond Fracture: Open Reduction and Internal Fixation Versus Limited Internal Fixation Combined With External Fixator.

    Science.gov (United States)

    Wang, Dong; Xiang, Jian-Ping; Chen, Xiao-Hu; Zhu, Qing-Tang

    2015-01-01

    The treatment of tibial plafond fractures is challenging to foot and ankle surgeons. Open reduction and internal fixation and limited internal fixation combined with an external fixator are 2 of the most commonly used methods of tibial plafond fracture repair. However, conclusions regarding the superior choice remain controversial. The present meta-analysis aimed to quantitatively compare the postoperative complications between open reduction and internal fixation and limited internal fixation combined with an external fixator for tibial plafond fractures. Nine studies with 498 fractures in 494 patients were included in the present study. The meta-analysis found no significant differences in bone healing complications (risk ratio [RR] 1.17, 95% confidence interval [CI] 0.68 to 2.01, p = .58], nonunion (RR 1.09, 95% CI 0.51 to 2.36, p = .82), malunion or delayed union (RR 1.24, 95% CI 0.57 to 2.69, p = .59), superficial (RR 1.56, 95% CI 0.43 to 5.61, p = .50) and deep (RR 1.89, 95% CI 0.62 to 5.80) infections, arthritis symptoms (RR 1.20, 95% CI 0.92 to 1.58, p = .18), or chronic osteomyelitis (RR 0.31, 95% CI 0.05 to 1.84, p = .20) between the 2 groups. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Management of intra-articular fracture of the fingers via mini external fixator combined with limited internal fixation

    Institute of Scientific and Technical Information of China (English)

    LI Wen-jun; TIAN Wen; TIAN Guang-lei; CHEN Shan-lin; ZHANG Chang-qing; XUE Yun-hao; LI Zhong-zhe; ZHU Yin

    2009-01-01

    Background Intra-articular fractures of the fingers are common problems to emergency physicians and hand surgeons.Inappropriate management of these injuries may result in chronic pain,stiffness,deformity,or post traumatic arthritis.Ideal treatment necessitates the restoration of a stable and congruent joint that will allow early mobilization.The purpose of this study was to investigate the results of intra-articular fracture of the fingers by mini external fixator combined with limited internal fixation.Methods From May 2005 to May 2007,a total of 26 patients with intra-articular fracture of the fingers were treated by mini external fixator combined with limited internal fixation.Of the 26 cases,11 involved in metacarpophalangeal joint,and 15 interphalangeal joint in proximal interphalangeal.Kirschner wire,mini wire and absorbable suture were used for limited internal fixation.All patients were followed up and patients were accomplished with total active motion(TAM)of fingers.Results All patients were reviewed by an independent observer.The mean follow up was 13 months(range 9 to 24 months).Subjective,objective and radiographic results were evaluated.X-ray films revealed fracture union and the average radiographic union time was 7 weeks with a range of 5-12 weeks and the phalange shortening or rotation in 2 cases,joint incongruity(less than 1 mm)and joint space narrowing in 3 cases respectively.Phalangeal shortening or rotation was observed in 2 cases and joint incongruity or joint space narrowing was observed in 3 cases.An artificial implant was performed on one case for traumatic arthritis 1.5 years after surgery.Based on TAM the overall good-excellent rate of joint motion function was 80.8%.Conclusion Mini external fixator combined with limited internal fixation is a reliable and effective method for treatment of intra-articular fracture of the fingers.

  1. Study of Hip Fracture Risk using Tree Structured Survival Analysis

    Directory of Open Access Journals (Sweden)

    Lu Y

    2003-01-01

    Full Text Available In dieser Studie wird das Hüftfraktur-Risiko bei postmenopausalen Frauen untersucht, indem die Frauen in verschiedene Subgruppen hinsichtlich dieses Risikos klassifiziert werden. Frauen in einer gemeinsamen Subgruppe haben ein ähnliches Risiko, hingegen in verschiedenen Subgruppen ein unterschiedliches Hüftfraktur-Risiko. Die Subgruppen wurden mittels der Tree Structured Survival Analysis (TSSA aus den Daten von 7.665 Frauen der SOF (Study of Osteoporosis Fracture ermittelt. Bei allen Studienteilnehmerinnen wurde die Knochenmineraldichte (BMD von Unterarm, Oberschenkelhals, Hüfte und Wirbelsäule gemessen. Die Zeit von der BMD-Messung bis zur Hüftfraktur wurde als Endpunkt notiert. Eine Stichprobe von 75% der Teilnehmerinnen wurde verwendet, um die prognostischen Subgruppen zu bilden (Trainings-Datensatz, während die anderen 25% als Bestätigung der Ergebnisse diente (Validierungs-Datensatz. Aufgrund des Trainings-Datensatzes konnten mittels TSSA 4 Subgruppen identifiziert werden, deren Hüftfraktur-Risiko bei einem Follow-up von im Mittel 6,5 Jahren bei 19%, 9%, 4% und 1% lag. Die Einteilung in die Subgruppen erfolgte aufgrund der Bewertung der BMD des Ward'schen Dreiecks sowie des Oberschenkelhalses und nach dem Alter. Diese Ergebnisse konnten mittels des Validierungs-Datensatzes reproduziert werden, was die Sinnhaftigkeit der Klassifizierungregeln in einem klinischen Setting bestätigte. Mittels TSSA war eine sinnvolle, aussagekräftige und reproduzierbare Identifikation von prognostischen Subgruppen, die auf dem Alter und den BMD-Werten beruhen, möglich. In this paper we studied the risk of hip fracture for post-menopausal women by classifying women into different subgroups based on their risk of hip fracture. The subgroups were generated such that all the women in a particular subgroup had relatively similar risk while women belonging to two different subgroups had rather different risks of hip fracture. We used the Tree Structured

  2. Immediate Weight-Bearing after Ankle Fracture Fixation

    Directory of Open Access Journals (Sweden)

    Reza Firoozabadi

    2015-01-01

    Full Text Available We believe that a certain subset of surgical ankle fracture patients can be made weight-bearing as tolerated immediately following surgery. Immediate weight-bearing as tolerated (IWBAT allows patients to return to ambulation and activities of daily living faster and may facilitate rehabilitation. A prospectively gathered orthopaedic trauma database at a Level 1 trauma center was reviewed retrospectively to identify patients who had ORIF after unstable ankle injuries treated by the senior author. Patients were excluded if they were not IWBAT based on specific criteria or if they did meet followup requirement. Only 1/26 patients was noted to have loss of fixation. This was found at the 6-week followup and was attributed to a missed syndesmotic injury. At 2-week followup, 2 patients had peri-incisional erythema that resolved with a short course of oral antibiotics. At 6-week followup, 20 patients were wearing normal shoes and 6 patients continued to wear the CAM Boot for comfort. To conclude, IWBAT in a certain subset of patients with stable osteosynthesis following an ankle fracture could potentially be a safe alternative to a period of protected weight-bearing.

  3. Closed hip and long bone fractures The regimen effectiveness of antibiotic prophylaxis in surgical fixation%闭合性髋部骨折或长骨骨折围手术期抗生素预防性应用的疗效分析

    Institute of Scientific and Technical Information of China (English)

    Dan C Norvell; 王簕; 杨云峰

    2009-01-01

    对22项随机对照研究进行Meta分析,以评价在闭合性髋部骨折或长骨骨折的围手术期中,静脉预防性抗生素应用的疗效.与未应用静脉抗生素组相比,术前静脉应用抗生素(术前单剂量抗生素应用或术前联合术后多次应用)可以明显降低术后深部感染、浅表感染、泌尿道感染的发生率.当应用短效抗生素预防术中感染时,多次剂量应用可以明显降低感染的发生率.但是,当应用长效抗生素预防感染时,单剂量应用组与多剂量应用其他短效抗生素组效果相当.在比较抗生素多剂量给药疗法间或不同给药方式间(口服或静脉给药)对预防感染的疗效时发现,不论采取何种方法 ,预防感染的效果均无明显差异.%A metaanalysis of 22 randomized controlled trials found evidence to support parenteral antibiotic prophylaxis regimens for patients undergoing surgical fixation of closed hip and long bone fractures. Preoperative parenteral antibiotic doses (single or combined with multiple postoperative doses) resulted in decreased risk of deep, superficial, and urinary tract infections compared with no antibiotic. Single doses of short acting agents may be less effective than multiple doses of the same agent in decreasing the risk of any of the infections evaluated. By contrast, there was no significant difference in infection risk between a single dose of a long acting agent and multiple doses of other agents with shorter half lives. No significant differences were found when multiple dose regimens were compared or when administration routes (oral versus parenteral) were compared.

  4. K-wire fixation for redislocated Colles' fractures - Malunion in 8/21 cases

    NARCIS (Netherlands)

    Oskam, J; Kingma, J; Bart, J; Klasen, HJ

    One therapeutic alternative for redislocation of Colles' fractures is closed reduction and transstyloid Kirschner-wire fixation. We describe our results concerning 21 redislocations treated in this way. According to Older's classification, 8 fractures were type 3 and 13 fractures type 4. After a

  5. Effects of Teriparatide Compared with Risedronate on Recovery After Pertrochanteric Hip Fracture

    DEFF Research Database (Denmark)

    Aspenberg, Per; Malouf, Jorge; Tarantino, Umberto;

    2016-01-01

    BACKGROUND: Osteoporosis drugs might affect fracture-healing. We therefore studied the effects of teriparatide in comparison with risedronate on recovery after pertrochanteric hip fractures. METHODS: The study was a randomized, multicenter, active-controlled, 78-week trial comparing teriparatide ...

  6. A critical review of the long-term disability outcomes following hip fracture

    National Research Council Canada - National Science Library

    Dyer, Suzanne M; Crotty, Maria; Fairhall, Nicola; Magaziner, Jay; Beaupre, Lauren A; Cameron, Ian D; Sherrington, Catherine

    2016-01-01

    .... Studies were identified through PubMed and Scopus searches and contact with experts. Cohort studies of hip fracture patients reporting outcomes 3 months post-fracture or longer were included for review...

  7. Does Early Functional Outcome Predict 1-year Mortality in Elderly Patients With Hip Fracture?

    National Research Council Canada - National Science Library

    Dubljanin-Raspopović, Emilija; Marković-Denić, Ljiljana; Marinković, Jelena; Nedeljković, Una; Bumbaširević, Marko

    2013-01-01

    ... fractures.A total of 228 consecutive patients (average age, 77.6 ± 7.4 years) with hip fractures who met the inclusion criteria were enrolled in an open, prospective, observational cohort study...

  8. The effect of cement on hip stem fixation: a biomechanical study.

    Science.gov (United States)

    Çelik, Talip; Mutlu, İbrahim; Özkan, Arif; Kişioğlu, Yasin

    2017-06-01

    This study presents the numerical analysis of stem fixation in hip surgery using with/without cement methods since the use of cement is still controversial based on the clinical studies in the literature. Many different factors such as stress shielding, aseptic loosening, material properties of the stem, surgeon experiences etc. play an important role in the failure of the stem fixations. The stem fixation methods, cemented and uncemented, were evaluated in terms of mechanical failure aspects using computerized finite element method. For the modeling processes, three dimensional (3D) femur model was generated from computerized tomography (CT) images taken from a patient using the MIMICS Software. The design of the stem was also generated as 3D CAD model using the design parameters taken from the manufacturer catalogue. These 3D CAD models were generated and combined with/without cement considering the surgical procedure using SolidWorks program and then imported into ANSYS Workbench Software. Two different material properties, CoCrMo and Ti6Al4V, for the stem model and Poly Methyl Methacrylate (PMMA) for the cement were assigned. The material properties of the femur were described according to a density calculated from the CT images. Body weight and muscle forces were applied on the femur and the distal femur was fixed for the boundary conditions. The calculations of the stress distributions of the models including cement and relative movements of the contacts examined to evaluate the effects of the cement and different stem material usage on the failure of stem fixation. According to the results, the use of cement for the stem fixation reduces the stress shielding but increases the aseptic loosening depending on the cement crack formations. Additionally, using the stiffer material for the stem reduces the cement stress but increases the stress shielding. Based on the results obtained in the study, even when taking the disadvantages into account, the cement usage

  9. The relationship between interfragmentary movement and cell differentiation in early fracture healing under locking plate fixation.

    Science.gov (United States)

    Miramini, Saeed; Zhang, Lihai; Richardson, Martin; Mendis, Priyan; Oloyede, Adekunle; Ebeling, Peter

    2016-03-01

    Interfragmentary movement (IFM) at the fracture site plays an important role in fracture healing, particularly during its early stage, via influencing the mechanical microenvironment of mesenchymal stem cells within the fracture callus. However, the effect of changes in IFM resulting from the changes in the configuration of locking plate fixation on cell differentiation has not yet been fully understood. In this study, mechanical experiments on surrogate tibia specimens, manufactured from specially formulated polyurethane, were conducted to investigate changes in IFM of fractures under various locking plate fixation configurations and loading magnitudes. The effect of the observed IFM on callus cell differentiation was then further studied using computational simulation. We found that during the early stage, cell differentiation in the fracture callus is highly influenced by fracture gap size and IFM, which in turn, is highly sensitive to locking plate fixation configuration. The computational model predicted that a small gap size (e.g. 1 mm) under a relatively flexible configuration of locking plate fixation (larger bone-plate distances and working lengths) could experience excessive strain and fluid flow within the fracture site, resulting in excessive fibrous tissue differentiation and delayed healing. By contrast, a relatively flexible configuration of locking plate fixation was predicted to improve cartilaginous callus formation and bone healing for a relatively larger gap size (e.g. 3 mm). If further confirmed by animal and human studies, the research outcome of this paper may have implications for orthopaedic surgeons in optimising the application of locking plate fixations for fractures in clinical practice.

  10. Revision Total Hip Arthroplasty Using a Modular Tapered Stem With Distal Fixation Good Short-Term Results in 125 Revisions

    DEFF Research Database (Denmark)

    Ovesen, Ole; Emmeluth, Claus; Hofbauer, Christian;

    2009-01-01

    After 2 to 7 years we reviewed 125 prosthetic hip arthroplasty stem revisions using a modular tapered stem with distal fixation. Median age of these patients was 68 (33-92) years. Baseline and follow-up data were registered prospectively according to the Danish Hip Arthroplasty Registry. Survival...

  11. Hip resurfacing femoral neck fracture influenced by valgus placement.

    Science.gov (United States)

    Anglin, Carolyn; Masri, Bassam A; Tonetti, Jérôme; Hodgson, Antony J; Greidanus, Nelson V

    2007-12-01

    Femoral neck fracture is the most common short-term concern after hip resurfacing arthroplasty. Currently, there is little basis to decide between neutral and valgus placement. We loaded 10 notched cadaveric femur pairs to failure; one side was implanted at 0 degrees relative to the femoral neck and the other at 10 degrees valgus. All 20 were dual-energy X-ray absorptiometry-scanned. Failure load correlated with bone mineral density. Valgus placement increased the fracture load by an average of 28% over neutral for specimens with normal bone mineral density but had no effect on fracture load in specimens with low bone mineral density. For specimens with normal bone mineral density (typical of patients undergoing resurfacing arthroplasty), neutral-valgus placement had a greater effect than bone mineral density, explaining 54% of the fracture load variance. Component placement greater than 10 degrees valgus is likely undesirable because this can lead to an increase in component size and a greater likelihood of notching. To reduce fracture risk, we recommend placing the femoral component in valgus and selecting patients with higher bone mineral density.

  12. COMBINATION OF FIXATION TECHNIQUES IN THE MANAGEMENT OF COMPLEX DISTAL RADIUS FRACTURE- OUR EXPERIENCES

    Directory of Open Access Journals (Sweden)

    Isaac Sunder Sen

    2016-10-01

    Full Text Available BACKGROUND The aim of the study is to categorically suggest the apt method of surgical technique for a particular type of distal radius fracture (Frykman’s type III-VI. Distal radius fracture are among the most common fractures of the upper extremity inspite of increased focus on regular prevention of osteoporosis, early identification and its prompt management. Most distal radius fractures are the result of low energy mechanisms that can be successfully treated either nonoperatively or with a variety of operative techniques if indicated. Complex distal radius fractures occur most commonly in high-energy injuries with extensive comminution or bone loss and associated soft tissue or vascular injuries. These high-energy fractures can present challenges in reconstructing the distal radius. Effective restoration of the bony architecture requires a thorough knowledge of distal radius anatomy, understanding of the goals of treatment, versatility in surgical approaches and familiarity with multiple fixation options. Although, majority of the extra-articular fracture without signs of instability can be successfully managed with POP immobilisation for a period of 4-5 weeks followed by active physiotherapy, other types (Frykman’s III-VI need surgical management that too with combination of surgical techniques namely augmented spanning external fixator with supplemented K-wire fixation or external fixation followed by fragment specific volar locking compression plate osteosynthesis. MATERIALS AND METHODS I have studied 50 cases of distal radius fractures classified using Frykman’s classification using combination of techniques namely augmented spanning external fixator application with K-wire supplementation and spanning external fixator application followed by volar LCP fixation in which external fixator had been used as a reduction tool in majority of the cases and external fixator had been removed after plate osteosynthesis. In some cases retained

  13. Treatment of acetabular fractures in older patients-introduction of a new implant for primary total hip arthroplasty.

    Science.gov (United States)

    Resch, H; Krappinger, D; Moroder, P; Auffarth, A; Blauth, M; Becker, J

    2017-04-01

    Fractures of the acetabulum in younger patients are commonly treated by open reduction and internal fixation. For elderly patients, stable primary total hip arthroplasty with the advantage of immediate postoperative mobilization might be the adequate treatment. For this purpose, a sufficiently stable fixation of the acetabular component is required. Between August 2009 and 2014, 30 cases were reported in which all patients underwent total hip arthroplasty additionally to a customized implant designed as an antiprotrusion cage. Inclusion criteria were an acetabular fracture with or without a previous hemiarthroplasty, age above 65 years, and pre-injury mobility dependent on a walking frame at the most. The median age was 79.9 years (65-92), and of 30 fractures, 25 were primary acetabular fractures (83%), four periprosthetic acetabular fractures (14%), and one non-union after a failed ORIF (3%). The average time from injury to surgery was 9.4 days (3-23) and 295 days for the non-union case. Mean time of surgery was 154.4 min (range 100 to 303). In 21 cases (70%), mobilization with full weight bearing was possible within the first 10 days. Six patients died before the follow-up examination 3 and 6 months after surgery, while 24 patients underwent radiologic examination showing consolidated fractures in bi-plane radiographs. In 9 patients, additional CT scan was performed which confirmed the radiographical results. 13 had regained their pre-injury level of mobility including the non-union case. Only one patient did not regain independent mobility. Four complications were recognized with necessary surgical revision (one prosthetic head dislocation, one pelvic cement leakage, one femoral shaft fracture, and one infected hematoma). The presented cage provides the possibility of early mobilization with full weight bearing which represents a valuable addition to the treatment spectrum in this challenging patient group.

  14. Multiplanar Fixation for Patella Fractures Using a Low-Profile Mesh Plate.

    Science.gov (United States)

    Lorich, Dean G; Warner, Stephen J; Schottel, Patrick C; Shaffer, Andre D; Lazaro, Lionel E; Helfet, David L

    2015-12-01

    Patella fractures are challenging orthopaedic injuries. Many commonly used fixation techniques can be ineffective and lead to poor clinical outcomes even with satisfactory reductions and fracture healing. In this investigation, we present the technique of cage plate fixation of patella fractures and the clinical outcomes of 9 initial patients surgically treated at our institution. This technique allows direct visualization of the articular reduction, provides multiplanar fixation, effectively stabilizes inferior pole comminution, and reduces the risk of patella vascular disruption. Using this technique, we have achieved excellent functional and radiographic outcomes.

  15. Direct costs of osteoporosis and hip fracture: an analysis for the Mexican healthcare system.

    Science.gov (United States)

    Clark, P; Carlos, F; Barrera, C; Guzman, J; Maetzel, A; Lavielle, P; Ramirez, E; Robinson, V; Rodriguez-Cabrera, R; Tamayo, J; Tugwell, P

    2008-03-01

    This study reports the direct costs related to osteoporosis and hip fractures paid for governmental and private institutions in the Mexican health system and estimates the impact of these entities on Mexico. We conclude that the economic burden due to the direct costs of hip fracture justifies wide-scale prevention programs for osteoporosis (OP). To estimate the total direct costs of OP and hip fractures in the Mexican Health care system, a sample of governmental and private institutions were studied. Information was gathered through direct questionnaires in 275 OP patients and 218 hip fracture cases. Additionally, a chart review was conducted and experts' opinions obtained to get accurate protocol scenarios for diagnoses and treatment of OP with no fracture. Microcosting and activity-based costing techniques were used to yield unit costs. The total direct costs for OP and hip fracture were estimated for 2006 based on the projected annual incidence of hip fractures in Mexico. A total of 22,233 hip fracture cases were estimated for 2006 with a total cost to the healthcare system of US$ 97,058,159 for the acute treatment alone ($4,365.50 per case). We found considerable differences in costs and the way the patients were treated across the different health sectors within the country. Costs of the acute treatment of hip fractures in Mexico are high and are expected to increase with the predicted increment of life expectancy and the number of elderly in our population.

  16. Hip fracture epidemiological trends, outcomes, and risk factors, 1970–2009

    Science.gov (United States)

    Marks, Ray

    2010-01-01

    Hip fractures – which commonly lead to premature death, high rates of morbidity, or reduced life quality – have been the target of a voluminous amount of research for many years. But has the lifetime risk of incurring a hip fracture decreased sufficiently over the last decade or are high numbers of incident cases continuing to prevail, despite a large body of knowledge and a variety of contemporary preventive and refined surgical approaches? This review examines the extensive hip fracture literature published in the English language between 1980 and 2009 concerning hip fracture prevalence trends, and injury mechanisms. It also highlights the contemporary data concerning the personal and economic impact of the injury, plus potentially remediable risk factors underpinning the injury and ensuing disability. The goal was to examine if there is a continuing need to elucidate upon intervention points that might minimize the risk of incurring a hip fracture and its attendant consequences. Based on this information, it appears hip fractures remain a serious global health issue, despite some declines in the incidence rate of hip fractures among some women. Research also shows widespread regional, ethnic and diagnostic variations in hip fracture incidence trends. Key determinants of hip fractures include age, osteoporosis, and falls, but some determinants such as socioeconomic status, have not been well explored. It is concluded that while more research is needed, well-designed primary, secondary, and tertiary preventive efforts applied in both affluent as well as developing countries are desirable to reduce the present and future burden associated with hip fracture injuries. In this context, and in recognition of the considerable variation in manifestation and distribution, as well as risk factors underpinning hip fractures, well-crafted comprehensive, rather than single solutions, are strongly indicated in early rather than late adulthood. PMID:20463818

  17. Team management of the elderly patient with hip fracture.

    Science.gov (United States)

    Pryor, G A; Myles, J W; Williams, D R; Anand, J K

    1988-02-20

    The management of 200 consecutive patients with hip fracture by a joint hospital and community team in Peterborough has shown that over half the patients could be discharged considerably earlier than is usual. The patients are cared for at home by the hospital-at-home nursing service and generally need much less nursing care than patients treated conventionally. In the first 10 months of the scheme 733 inpatient bed-days were saved and the average hospital stay of patients discharged home was reduced from 22.0 to 14.6 days.

  18. Patella fracture fixation with suture and wire: you reap what you sew.

    Science.gov (United States)

    Egol, Kenneth; Howard, Daniel; Monroy, Alexa; Crespo, Alexander; Tejwani, Nirmal; Davidovitch, Roy

    2014-01-01

    Operative fixation of displaced inferior pole patella fractures has now become the standard of care. This study aims to quantify clinical, radiographic and functional outcomes, as well as identify complications in a cohort of patients treated with non-absorbable braided suture fixation for inferior pole patellar fractures. These patients were then compared to a control group of patients treated for mid-pole fractures with K-wires or cannulated screws with tension band wiring. In this IRB approved study, we identified a cohort of patients who were diagnosed and treated surgically for a displaced patella fracture. Demographic, injury, and surgical information were recorded. All patients were treated with a standard surgical technique utilizing non-absorbable braided suture woven through the patellar tendon and placed through drill holes to achieve reduction and fracture fixation. All patients were treated with a similar post-operative protocol and followed up at standard intervals. Data were collected concurrently at follow up visits. For purpose of comparison, we identified a control cohort with middle third patella fractures treated with either k-wires or cannulated screws and tension band technique. Patients were followed by the treating surgeon at regular follow-up intervals. Outcomes included self-reported function and knee range of motion compared to the uninjured side. Forty-nine patients with 49 patella fractures identified retrospectively were treated over 9 years. This cohort consisted of 31 females (63.3%) and 18 males (36.7%) with an average age of 57.1 years (range 26-88 years). Patients had an average BMI of 26.48 (range 19-44.08). Thirteen patients with inferior pole fractures underwent suture fixation and 36 patients with mid-pole fractures underwent tension band fixation (K-wire or cannulated screws with tension band). In the suture cohort, one fracture failed open repair (7.6%), which was revised again with sutures and progressed to union. Of the 36

  19. Rigid internal fixation of zygoma fractures: A comparison of two-point and three-point fixation

    OpenAIRE

    2007-01-01

    Background: Displaced fractures of the zygomatic bone can result in significant functional and aesthetic sequelae. Therefore the treatment must achieve adequate and stable reduction at fracture sites so as to restore the complex multidimensional relationship of the zygoma to the surrounding craniofacial skeleton. Many experimental biophysical studies have compared stability of zygoma after one, two and three-point fixation with mini plates. We conducted a prospective clinical study comparing...

  20. Distal fibula fracture fixation: Biomechanical evaluation of three different fixation implants.

    Science.gov (United States)

    Knutsen, Ashleen R; Sangiorgio, Sophia N; Liu, Chang; Zhou, Steve; Warganich, Tibor; Fleming, John; Harris, Thomas G; Ebramzadeh, Edward

    2016-12-01

    The goal of this study was to evaluate the biomechanical performance of three distal fibula fracture fixation implants in a matched pair cadaveric fibula model: (1) a 5-hole compression plate with lag screw, (2) a 5-hole locking plate with lag screw, and (3) the 6-hole tabbed-plate with locking screws. Three-dimensional motions between the proximal and distal fibular segments were measured under cyclic valgus bending, cyclic compressive axial loading, and cyclic torsional external-rotation loading. During loading, strains were measured on the surfaces of each fibula near the simulated fracture site, and on the plate, to assess load transfer. Bone quality was quantified globally for each donor using bone mineral density (BMD) measured using Dual X-ray absorptiometry (DEXA) and locally at the fracture site using bone mineral content (BMC) measured using peripheral quantitative computed tomography (pQCT). Mean failure loads were below 0.2Nm of valgus bending and below 4Nm of external-rotational torque. Mean failure angulation was below 1degree for valgus bending, and failure rotation was below 7degrees for external-rotation. In the compression plate group, significant correlations were observed between bone quality (global BMD and local BMC) and strain in every one of the five locations (Pearson correlation coefficients >0.95, p<0.05). In contrast, in the locking and tabbed-plate groups, BMD and BMC correlated with far fewer strain locations. Overall, the tabbed-plate had similar construct stability and strength to the compression and locking plates. However, the distribution of load with the locking and tabbed-plates was not as heavily dependent on bone quality. Copyright © 2016 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  1. Evaluation of pediatric lower extremity fractures managed with external fixation: outcomes in a deployed environment.

    Science.gov (United States)

    Eichinger, Josef K; McKenzie, Colin S; Devine, John G

    2012-01-01

    External fixation of pediatric lower extremity fractures is usually reserved for severe, open fractures in polytraumatized patients, but it is often the only available treatment option for deployed military surgeons. We analyzed the outcomes and complications of 17 consecutive pediatric long bone fractures treated with external fixation at a Forward Surgical Team facility in an austere environment during Operation Enduring Freedom in Afghanistan during a 12-month period. Treatment consisted of uniplanar external fixation for 12 femoral shaft fractures (11 closed), 4 tibial shaft fractures (all open), and 1 subtrochanteric fracture (closed) in 14 males and 3 females with an average age of 7.4 years. All 17 fractures went on to union with no incidences of refracture. Complications included 1 broken pin and 3 pin site infections treated with wound care and oral antibiotics. In a deployed environment, external fixation is the treatment method of choice for lower extremity fractures by virtue of patient, environment, equipment, and mission factors. This case series validates the usage of a simple, uniplanar external fixator for a variety of open and closed pediatric long bone fractures as evidenced by the successful union rate and low number of complications.

  2. Hip fracture risk estimation based on principal component analysis of QCT atlas: a preliminary study

    Science.gov (United States)

    Li, Wenjun; Kornak, John; Harris, Tamara; Lu, Ying; Cheng, Xiaoguang; Lang, Thomas

    2009-02-01

    We aim to capture and apply 3-dimensional bone fragility features for fracture risk estimation. Using inter-subject image registration, we constructed a hip QCT atlas comprising 37 patients with hip fractures and 38 age-matched controls. In the hip atlas space, we performed principal component analysis to identify the principal components (eigen images) that showed association with hip fracture. To develop and test a hip fracture risk model based on the principal components, we randomly divided the 75 QCT scans into two groups, one serving as the training set and the other as the test set. We applied this model to estimate a fracture risk index for each test subject, and used the fracture risk indices to discriminate the fracture patients and controls. To evaluate the fracture discrimination efficacy, we performed ROC analysis and calculated the AUC (area under curve). When using the first group as the training group and the second as the test group, the AUC was 0.880, compared to conventional fracture risk estimation methods based on bone densitometry, which had AUC values ranging between 0.782 and 0.871. When using the second group as the training group, the AUC was 0.839, compared to densitometric methods with AUC values ranging between 0.767 and 0.807. Our results demonstrate that principal components derived from hip QCT atlas are associated with hip fracture. Use of such features may provide new quantitative measures of interest to osteoporosis.

  3. Anabolic steroids for rehabilitation after hip fracture in older people

    Directory of Open Access Journals (Sweden)

    Vaqas Farooqi

    Full Text Available ABSTRACT BACKGROUND: Hip fracture occurs predominantly in older people, many of whom are frail and undernourished. After hip fracture surgery and rehabilitation, most patients experience a decline in mobility and function. Anabolic steroids, the synthetic derivatives of the male hormone testosterone, have been used in combination with exercise to improve muscle mass and strength in athletes. They may have similar effects in older people who are recovering from hip fracture. OBJECTIVES: To examine the effects (primarily in terms of functional outcome and adverse events of anabolic steroids after surgical treatment of hip fracture in older people. METHODS: Search methods: We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialized Register (10 September 2013, the Cochrane Central Register of Controlled Trials (CENTRAL (The Cochrane Library, 2013 Issue 8, MEDLINE (1946 to August Week 4 2013, EMBASE (1974 to 2013 Week 36, trial registers, conference proceedings, and reference lists of relevant articles. The search was run in September 2013. Selection criteria: Randomized controlled trials of anabolic steroids given after hip fracture surgery, in inpatient or outpatient settings, to improve physical functioning in older patients with hip fracture. Data collection and analysis: Two review authors independently selected trials (based on predefined inclusion criteria, extracted data and assessed each study's risk of bias. A third review author moderated disagreements. Only very limited pooling of data was possible. The primary outcomes were function (for example, independence in mobility and activities of daily living and adverse events, including mortality. MAIN RESULTS: We screened 1290 records and found only three trials involving 154 female participants, all of whom were aged above 65 years and had had hip fracture surgery. All studies had methodological shortcomings that placed them at high or unclear risk of bias. Because of this high

  4. A COMPARATIVE STUDY OF CONSERVATIVE MANAGEMENT VS. EXTERNAL FIXATION OF COMMINUTED DISTAL RADIUS FRACTURES

    Directory of Open Access Journals (Sweden)

    Sanjeev Kumar Kare

    2016-12-01

    Full Text Available BACKGROUND Fracture of the distal radius (‘broken wrist’ is a common clinical problem. It can be treated conservatively usually involving wrist immobilisation in a plaster cast or surgically. A key method of surgical fixation is external fixation. MATERIALS AND METHODS A prospective study was carried out on 66 patients admitted between June 2014 to May 2016 for evaluation of conservative and surgical management of distal radius fractures. RESULTS Excellent, fair or good result was noticed in around 85% of cases managed conservatively and in above 90% of cases managed by external fixator. CONCLUSION There is some evidence to support the use of external fixation for dorsally displaced fractures of the distal radius in adults. Though, there is insufficient evidence to confirm a better functional outcome, external fixation reduces redisplacement gives improved anatomical results and most of the excess surgically-related complications are minor.

  5. Talar neck fractures treated with closed reduction and percutaneous screw fixation:a case series.

    Science.gov (United States)

    Fernandez, Michael L; Wade, Allison M; Dabbah, Michael; Juliano, Paul J

    2011-02-01

    Talus fractures are relatively rare injuries, accounting for approximately 3% of all foot fractures. Fractures of the talar neck account for almost 50% of all talus fractures. Diagnosis and treatment of these fractures play an important role in patients' outcomes. Treatment of talar neck fractures has slowly evolved from closed treatment to open reduction and internal fixation. Treatment of type I and type II talar neck fractures is debated in the orthopedic community. Choosing which treatment to perform depends on injury severity, associated injuries, and surgeon experience and preference. In this article, we report on our retrospective review of all talar neck fractures treated with closed reduction and percutaneous fixation between 1996 and 2001 at the Pennsylvania State University Milton S. Hershey Medical Center.

  6. [Periprosthetic Femoral Fractures after Total Hip Replacement: Our Results and Treatment Complications].

    Science.gov (United States)

    Pavelka, T; Salášek, M; Weisová, D

    2017-01-01

    cables. Osseointegration of the stem was recorded in 24 patients, one female patient died 4 months after the surgery. An excellent result was achieved in 16 patients (64%), a very good result in 4 patients (16%). The remaining 5 patients (20%) failed to meet the minimum follow-up of 3 years. In 8 patients with type B3 trauma, the reimplant of a revision stem was supplemented by spongioplasty, in 2 cases by solid corticocancellous bone grafts with cerclage. In this group osseointegration occurred in all the cases within 6-9 months. The follow-up was affected by the older age of patients and 6 patients died during the follow-up period. The requirement of a follow-up longer than 3 years was met in 2 patients (25%) only and the result was considered very good. In the group of 19 patients with type C fracture, plate osteosynthesis was performed, which was in 12 cases complemented with spongioplasty. Healing occurred within 6 months in 13 patients (72%), within 9 months in 3 patients (17%) and in 2 patients (11%) reoperation was carried out due to fixation failure. One female patient died 16 days after the surgery. An excellent result was achieved in 15 patients (83%), in the remaining three patients the follow-up was shorter than three years due to their death. DISCUSSION Periprosthetic femoral fractures after total hip replacement is a rare but feared complication. Its incidence ranges from 0.1 to 4%. It occurs most frequently 7 to 8 years after the primary implant and 3 to 4 years after the revision of endoprosthesis implantation. The main risk factor is the loosening of stem of endoprosthesis. Another risk factor is osteoporosis. Age, sex and obesity do not constitute significant risk factors. Stem stability and presence of bone defects are the main criteria in favour of surgical treatment. If the stem remains well fixed, the osteosynthesis is opted for, whereas if the stem is loose, its replacement has to be performed. The management of bone defects is an integral part of

  7. Prefracture functional level evaluated by the New Mobility Score predicts in-hospital outcome after hip fracture surgery

    DEFF Research Database (Denmark)

    Kristensen, Morten T; Foss, Nicolai Bang; Ekdahl, Charlotte

    2010-01-01

    Clinicians need valid and easily applicable predictors of outcome in patients with hip fracture. Adjusting for previously established predictors, we determined the predictive value of the New Mobility score (NMS) for in-hospital outcome in patients with hip fracture....

  8. Emergency department external fixation for provisional treatment of pilon and unstable ankle fractures

    Directory of Open Access Journals (Sweden)

    Craig R Lareau

    2015-01-01

    Full Text Available Unstable ankle fractures and impacted tibial pilon fractures often benefit from provisional external fixation as a temporizing measure prior to definitive fixation. Benefits of external fixation include improved articular alignment, decreased articular impaction, and soft tissue rest. Uniplanar external fixator placement in the Emergency Department (ED ex-fix is a reliable and safe technique for achieving ankle reduction and stability while awaiting definitive fixation. This procedure involves placing transverse proximal tibial and calcaneal traction pins and connecting the pins with two external fixator rods. This technique is particularly useful in austere environments or when the operating room is not immediately available. Additionally, this bedside intervention prevents the patient from requiring general anesthesia and may be a cost-effective strategy for decreasing valuable operating time. The ED ex-fix is an especially valuable procedure in busy trauma centers and during mass casualty events, in which resources may be limited.

  9. Martial arts fall training to prevent hip fractures in the elderly.

    NARCIS (Netherlands)

    Groen, B.E.; Smulders, E.; Kam, D. de; Duysens, J.E.J.; Weerdesteijn, V.G.M.

    2010-01-01

    Hip fractures are a common and serious consequence of falls. Training of proper fall techniques may be useful to prevent hip fractures in the elderly. The results suggested that martial arts fall techniques may be trainable in older individuals. Better performance resulted in a reduced impact force.

  10. Interrater Reliability of the 6-Minute Walk Test in Women With Hip Fracture

    DEFF Research Database (Denmark)

    Larsen, Camilla Marie; Overgaard, Jan; Holtze, Steffen

    2016-01-01

    of the 6MWT in individuals with hip fracture. Methods: Two senior physical therapy students independently examined a convenience sample of 20 participants in a randomized order. Their assessments were separated by 2 days and followed the guidelines of the American Thoracic Society. Hip fracture...

  11. Prediction of postoperative morbidity, mortality and rehabilitation in hip fracture patients

    DEFF Research Database (Denmark)

    Foss, Nicolai B; Kristensen, Morten T; Kehlet, Henrik

    2006-01-01

    To validate the cumulated ambulation score as an early postoperative predictor of short-term outcome in hip fracture patients.......To validate the cumulated ambulation score as an early postoperative predictor of short-term outcome in hip fracture patients....

  12. Exposure to antiepileptic drugs and the risk of hip fracture: a case-control study

    DEFF Research Database (Denmark)

    Tsiropoulos, Ioannis; Andersen, Morten; Nymark, Tine

    2008-01-01

    PURPOSE: To investigate whether the use of antiepileptic drugs (AEDs) increases the risk of hip fracture. METHODS: We performed a case-control study using data from the Funen County (population 2004: 475,000) hip fracture register. Cases (n = 7,557) were all patients admitted to county hospitals ...

  13. Martial arts fall training to prevent hip fractures in the elderly.

    NARCIS (Netherlands)

    Groen, B.E.; Smulders, E.; Kam, D. de; Duysens, J.E.J.; Weerdesteijn, V.G.M.

    2010-01-01

    Hip fractures are a common and serious consequence of falls. Training of proper fall techniques may be useful to prevent hip fractures in the elderly. The results suggested that martial arts fall techniques may be trainable in older individuals. Better performance resulted in a reduced impact force.

  14. High inter-tester reliability of the new mobility score in patients with hip fracture

    DEFF Research Database (Denmark)

    Kristensen, M.T.; Bandholm, T.; Foss, N.B.;

    2008-01-01

    OBJECTIVE: To assess the inter-tester reliability of the New Mobility Score in patients with acute hip fracture. DESIGN: An inter-tester reliability study. SUBJECTS: Forty-eight consecutive patients with acute hip fracture at a median age of 84 (interquartile range, 76-89) years; 40 admitted from...

  15. Quality of life after hip fracture in the elderly : A systematic literature review

    NARCIS (Netherlands)

    Peeters, C.M.M.; Visser, E.; van de Ree, C.L.P.; Gosens, T.; den Oudsten, B.L.; de Vries, J.

    2016-01-01

    Background With an increasing ageing population, hip fractures have become a major public health issue in the elderly. It is important to examine the health status (HS) and health-related quality of life (HRQOL) of the elderly faced with the epidemic of hip fractures. Objective To provide an

  16. Mortality in British hip fracture patients, 2000-2010 : a population-based retrospective cohort study

    NARCIS (Netherlands)

    Klop, Corinne; Welsing, Paco M J; Cooper, Cyrus; Harvey, Nicholas C; Elders, Petra J M; Bijlsma, Johannes W J; Leufkens, Hubert G M|info:eu-repo/dai/nl/075255049; de Vries, Frank|info:eu-repo/dai/nl/303546670

    BACKGROUND: Data on recent trends in mortality after hip fracture are scarce. Aims were therefore to examine secular trends in all-cause and cause-specific mortality post hip fracture and to compare this to the general population from 2000 to 2010. METHODS: Population-based cohort study within the

  17. Preoperative factors associated with red blood cell transfusion in hip fracture patients

    DEFF Research Database (Denmark)

    Madsen, Christian Medom; Jørgensen, Henrik Løvendahl; Norgaard, Astrid

    2014-01-01

    Red blood cell (RBC) transfusion is a frequently used treatment in patients admitted with a fractured hip, but the use remains an area of much debate. The aim of this study was to determine preoperative factors associated with the risk of receiving a red blood cell transfusion in hip fracture...

  18. Fascia iliaca compartment blockade for acute pain control in hip fracture patients

    DEFF Research Database (Denmark)

    Foss, Nicolai B; Kristensen, Billy B; Bundgaard, Morten

    2007-01-01

    Hip fracture patients are in severe pain upon arrival at the emergency department. Pain treatment is traditionally based on systemic opioids. No study has examined the effect of fascia iliaca compartment blockade (FICB) in acute hip fracture pain management within a double-blind, randomized setup....

  19. Potential Benefits of Rib Fracture Fixation in Patients with Flail Chest and Multiple Non-flail Rib Fractures.

    Science.gov (United States)

    Qiu, Meiguang; Shi, Zhanjun; Xiao, Jun; Zhang, Xuming; Ling, Shishui; Ling, Hao

    2016-12-01

    The purpose of this study is to evaluate the potential benefits of rib fracture fixation in patients with flail chest and multiple non-flail rib fractures versus conventional treatment modalities. A retrospective reviewed study compared 86 cases which received surgical treatment between June 2009 and May 2013 to 76 cases which received conservative treatment between January 2006 and May 2009. The patients were divided into the flail chest (n = 38) and multiple non-flail rib fracture groups (n = 124). In the flail chest group, the mechanical ventilation time, ICU monitoring time, tracheostomies, thoracic deformity, and impaired pulmonary function and return to full-time employment were compared. In the multiple non-flail rib fracture group, fracture healing, visual analog scale (VAS) pain score, inpatient length of stay, atelectatic, pulmonary complications, and normal activity-returning time were compared. Patients in the flail chest operative fixation group had significantly shorter ICU stay, decreased ventilator requirements, fewer tracheostomies, less thoracic deformity and impaired pulmonary function, and more returned to full-time employment. Patients in the multiple non-flail rib fracture operative fixation had shorter hospital stay, less pain, earlier return to normal activity, more fracture healing, less atelectasis, and fewer pulmonary infections. This study demonstrates the potential benefits of surgical stabilization of flail chest and multiple non-flail rib fractures with plate fixation. When compared with conventional conservative management, operatively managed patients demonstrated improved clinical outcomes.

  20. Risk factors for failure to return to the pre-fracture place of residence after hip fracture: a prospective longitudinal study of 444 patients

    NARCIS (Netherlands)

    A.J.H. Vochteloo (Anne); S.T. Vliet-Koppert; A.B. Maier (Andrea); W.E. Tuinebreijer (Wim); M.R. de Vries (Mark); R.M. Bloem (Rolf); R.G.H.H. Nelissen (Rob); P. Pilot (Peter)

    2012-01-01

    textabstractIntroduction: Long-term place of residence after hip fracture is not often described in literature. The goal of this study was to identify risk factors, known at admission, for failure to return to the pre-fracture place of residence of hip fracture patients in the Wrst year after a hip

  1. Risk factors for failure to return to the pre-fracture place of residence after hip fracture: a prospective longitudinal study of 444 patients

    NARCIS (Netherlands)

    A.J.H. Vochteloo (Anne); S.T. Vliet-Koppert; A.B. Maier (Andrea); W.E. Tuinebreijer (Wim); M.R. de Vries (Mark); R.M. Bloem (Rolf); R.G.H.H. Nelissen (Rob); P. Pilot (Peter)

    2012-01-01

    textabstractIntroduction: Long-term place of residence after hip fracture is not often described in literature. The goal of this study was to identify risk factors, known at admission, for failure to return to the pre-fracture place of residence of hip fracture patients in the Wrst year after a hip

  2. OUTCOME ANALYSIS OF PROXIMAL HUMERUS FRACTURES TREATED BY MINIMAL INTERNAL FIXATION

    Directory of Open Access Journals (Sweden)

    Venkatesh Kumar

    2014-05-01

    Full Text Available The aim of the study was to evaluate the functional outcome in patients treated with proximal humeral fracture who were treated with minimally internal fixations like K-wires, osteosutures etc.

  3. Fixation of tibial plateau fractures with synthetic bone graft versus natural bone graft: a comparison study.

    LENUS (Irish Health Repository)

    Ong, J C Y

    2012-06-01

    The goal of this study was to determine differences in fracture stability and functional outcome between synthetic bone graft and natural bone graft with internal fixation of tibia plateau metaphyseal defects.

  4. ASYMMETRICAL BILATERAL HIP DISLOCATION WITH SEGMENTAL FRACTURE FEMUR: AN UNUSUAL CASE REPORT AND LITERATURE REVIEW

    Directory of Open Access Journals (Sweden)

    Ramesh

    2015-01-01

    Full Text Available Bilateral traumatic hip dislocation is rarely seen. A unique case is presented, consisting of asymmetric bilateral hip dislocation with associated segmental fracture femur, resulting from fall from bus. This case represents an unusual, severe combination of injuries resulting from the fall from bus under influence of alcohol. Traumatic hip dislocation represents a true orthopaedic emergency . Given the severity of associated complications, every effort should be made to ensure pr ompt diagnosis and immediate therapy. We report our experience in the management of this complex injury pattern and review the pertinent literature on this subject. Keywords: Bilateral hip dislocation , Asymmetric hip dislocation , Segmental femur fracture , Closed reduction , Fall from bus .

  5. Ageism perceived by the elderly in Taiwan following hip fracture.

    Science.gov (United States)

    Huang, Yueh-Fang; Liang, Jersey; Shyu, Yea-Ing Lotus

    2014-01-01

    This qualitative, longitudinal study explored the feelings about and responses to discrimination experiences related to perceived ageism of older persons following hip fracture. Five male and six female hip-fractured elderly patients were sampled from a medical center in northern Taiwan. Semi-structured questionnaires were used to explore participants' experiences of and responses to ageism-related experiences. Data were collected in face-to-face interviews during home visits at 1, 3, 6, and 12 months after discharge from hospital, between June 2007 and December 2008. Textual data of participants' responses were analyzed by directed content analysis. All participants experienced ageism. In first 3 months after discharge, participants' main perceived ageism was positive because of their dependency and feeling overprotected by others. From 3 months to 1 year after discharge, other ageism experiences emerged: isolated because of physical restrictions and neglected. Furthermore, participants' responses were divided into two categories: disregard and tolerance of ageism, or becoming more independent because of ageism. The elderly participants considered that the influences of positive ageism in the early months after discharge reduced their autonomy and deprived them of power. This response to ageism was temporary; over time the participants tried to regain autonomy by overcoming their dependency and improving their physical functioning.

  6. Arthroscopic evaluation for omalgia patients undergoing the clavicular hook plate fixation of distal clavicle fractures

    OpenAIRE

    2014-01-01

    Background The aim of this study is to investigate the anatomic changes in the shoulder joints responsible for omalgia after the clavicular hook plate fixation under arthroscope. Methods Arthroscopic examination was carried out for 12 omalgia patients who underwent clavicular hook plate fixation due to distal clavicle fractures. Functional outcome of shoulder was measured by the Japanese Orthopaedic Association (JOA) score before and after the withdrawal of the fixation plate. Results The rot...

  7. Report About the Design of External Fixator for Treatment of Pelvis and Acetabulum Fractures

    Directory of Open Access Journals (Sweden)

    Martin JANEČKA

    2012-06-01

    Full Text Available Main point in this contribution is the design of external fixators applied in traumatology and orthopaedics. These fixators can be used in the treatment of open and unstable (i.e. complicated fractures of pelvis and its acetabulum. Numerical modelling (i.e. Finite Element Method, together with CAD modelling, experiments, material engineering, and nanotechnology are presented as a support for developing of a new design of external fixators.

  8. Benzodiazepines and risk of hip fractures in older people: a review of the evidence.

    Science.gov (United States)

    Cumming, Robert G; Le Couteur, David G

    2003-01-01

    A hip fracture epidemic is occurring in developed countries in association with population aging. The increasing number of people with a hip fracture has major implications for clinicians and health service managers. More importantly, a hip fracture is a devastating event in the life of an older person, as it often leads to loss of independence and death. Identification of risk factors for hip fracture is an essential first step towards prevention. The use of psychotropic medications is an established risk factor for hip fracture. The purpose of this article is to systematically review epidemiological studies of the relationship between use of benzodiazepines and risk of hip fracture and, then, to see how the findings of these studies fit with what is known about the pharmacology of benzodiazepines. Eleven primary epidemiological studies were identified. The results of these studies were not consistent; however, the inconsistency appeared to be almost entirely explained by research design. The studies that did not show an association between increased hip fracture risk and benzodiazepine use were nearly all hospital-based case-control studies, a type of study that often lacks validity because of the difficulty of finding an appropriate control group. After excluding the hospital-based case-control studies, all but one of the remaining seven studies found that use of benzodiazepines was associated with an increased risk of hip fracture that varied between 50% and 110%. The only higher quality study that did not find an association between benzodiazepine use and hip fracture was also the only study conducted entirely in nursing homes. There was no evidence that the risk of hip fracture differed between short- and long-acting benzodiazepines. People using higher doses of benzodiazepines and those who had recently started using benzodiazepines were at the highest risk of hip fracture. In very old people, there was some preliminary evidence that benzodiazepines that

  9. Geographic Variation in Osteoporotic Hip Fracture Incidence: The Growing Importance of Asian Influences in Coming Decades

    Directory of Open Access Journals (Sweden)

    D. K. Dhanwal

    2010-01-01

    Full Text Available Studies over the last few decades have demonstrated geographic variation in the incidence of hip fracture across continents and among different parts of the same region. This paper studies the epidemiology of hip fracture worldwide, with special emphasis on the geographic variation among Asian countries. Using the Pubmed database, keywords that were employed included hip fracture, incidence rate, geographic variation, osteoporosis, and epidemiology. Articles were chosen based on the basis of (1 focus: studies that were said to specifically focus on geographic variation in hip fracture from different continents with a focus on Asia; (2 language: studies that were in English; (3 methods: studies that used statistical tests to examine hip fracture incidence rates. The highest hip fracture rates are seen in Scandinavian countries and the US and the lowest in African countries. Fracture rates are intermediate in Asian populations. Among different ethnic populations, the highest fracture rates are seen in Caucasians and the lowest in blacks. There is also a north-south gradient, particularly in Europe, where more hip fractures occur in North Europe compared to the South.

  10. Transmasseteric antero-parotid facelift approach for open reduction and internal fixation of condylar fractures

    OpenAIRE

    Choi, Moon-Gi

    2015-01-01

    Surgical approaches to the condylar fracture include intraoral, preauricular, submandibular, and retromandibular approaches. Each approach has its own advantages and disadvantages. When a patient needs esthetic results and an intraoral approach is not feasible, the transmasseteric antero-parotid facelift approach is considered. This approach permits direct exposure and allow the surgeon to fixate the fractured unit tangentially. Tangential fixation is critical to osteosynthesis. Disadvantages...

  11. Long-term functional results after short-segment pedicle fixation of thoracolumbar fractures

    DEFF Research Database (Denmark)

    Mølmer, Michael; Gehrchen, Poul Martin; Dahl, Benny

    2013-01-01

    A retrospective study to assess the health-related quality of life in patients undergoing posterior fixation of thoracolumbar fractures, and to compare the outcome with norm scores and HRQL in patients undergoing surgical treatment for degenerative conditions of the spine.......A retrospective study to assess the health-related quality of life in patients undergoing posterior fixation of thoracolumbar fractures, and to compare the outcome with norm scores and HRQL in patients undergoing surgical treatment for degenerative conditions of the spine....

  12. Endoscopically assisted reduction and fixation of condylar neck/base fractures--The learning curve.

    Science.gov (United States)

    Loukota, R A

    2006-12-01

    Following the introduction of a new technique for fixation of fractures of the condylar neck and base in our department, the operative times were compared with those for the traditional and frequently used method of open reduction and internal fixation. A distinct learning curve was seen.

  13. Delayed cementless total hip arthroplasty for neglected dislocation of hip combined with complex acetabular fracture and deficient bone stock

    Directory of Open Access Journals (Sweden)

    Gavaskar Ashok S

    2012-12-01

    Full Text Available 【Abstract】Total hip arthroplasty (THA for an un-treated acetabular fracture is technically challenging and the long-term result is not so favorable. A 45-year-old fe-male patient with untreated column and comminuted poste-rior wall fracture of the acetabulum was treated in our insti-tution by reconstruction of the posterior wall using iliac strut autograft and plate stabilization of the posterior col-umn with cancellous grafting and cementless THA in a single stage. At 3 years’ follow-up, the patient was independently mobile without limb length discrepancy. Radiological evalu-ation showed well integrated components and bone grafts. No evidence of aseptic loosening or osteolysis was found. This report aims to emphasize that bony acetabular recon-struction allows the use of primary hip components, which improves prosthesis longevity and preserves bone stock for a future revision. Key words: Acetabulum; Fractures, bone; Hip dislocation; Arthroplasty, replacement, hip

  14. Early rehabilitation following less invasive surgical stabilisation plate fixation for distal femoral fractures.

    Science.gov (United States)

    Smith, T O; Hedges, C; MacNair, R; Schankat, K

    2009-06-01

    The less invasive surgical stabilisation (LISS) plate fixation method is an orthopaedic procedure for the fixation of distal femoral fractures. Early physiotherapy treatments of motion and mobilisation have been advocated following this procedure. This article critically appraises the evidence base assessing the early rehabilitation of patients following LISS fixation for distal femoral fractures. A review of EMBASE, Medline, CINAHL and AMED, and a hand search were undertaken. Two independent reviewers identified all eligible articles. Two reviewers extracted the data, which were verified by a third reviewer. All included articles were critically appraised by two independent reviewers using the Critical Appraisal Skills Programme tool. Seventeen case series assessing 508 patients with 535 fractures were reviewed. No clinical trials comparing physiotherapy programmes were identified. The review identified that following LISS fixation for distal femoral fractures, patients begin range-of-motion exercises immediately and are initially required to restrict weight-bearing following surgery. It remains unclear whether casts, braces or immobilisation aids are applied during the initial postoperative period. The efficacy of different physiotherapy protocols following LISS fixation for distal femoral fractures remains unclear. Further well-designed randomised controlled trials are required to compare different postoperative physiotherapy rehabilitation programmes for patients following LISS fixation of distal femoral fractures in order to determine the optimal postoperative management for this complex patient group.

  15. Education, marital status, and risk of hip fractures in older men and women: the CHANCES project.

    Science.gov (United States)

    Benetou, V; Orfanos, P; Feskanich, D; Michaëlsson, K; Pettersson-Kymmer, U; Ahmed, L A; Peasey, A; Wolk, A; Brenner, H; Bobak, M; Wilsgaard, T; Schöttker, B; Saum, K-U; Bellavia, A; Grodstein, F; Klinaki, E; Valanou, E; Papatesta, E-M; Boffetta, P; Trichopoulou, A

    2015-06-01

    The role of socioeconomic status in hip fracture incidence is unclear. In a diverse population of elderly, higher education was found to be associated with lower, whereas living alone, compared to being married/cohabiting, with higher hip fracture risk. Educational level and marital status may contribute to hip fracture risk. The evidence on the association between socioeconomic status and hip fracture incidence is limited and inconsistent. We investigated the potential association of education and marital status with hip fracture incidence in older individuals from Europe and USA. A total of 155,940 participants (79 % women) aged 60 years and older from seven cohorts were followed up accumulating 6456 incident hip fractures. Information on education and marital status was harmonized across cohorts. Hip fractures were ascertained through telephone interviews/questionnaires or through record linkage with registries. Associations were assessed through Cox proportional hazard regression adjusting for several factors. Summary estimates were derived using random effects models. Individuals with higher education, compared to those with low education, had lower hip fracture risk [hazard ratio (HR) = 0.84, 95 % confidence interval (CI) 0.72-0.95]. Respective HRs were 0.97 (95 % CI 0.82-1.13) for men and 0.75 (95 % CI 0.65-0.85) for women. Overall, individuals living alone, especially those aged 60-69 years, compared to those being married/cohabiting, tended to have a higher hip fracture risk (HR = 1.12, 95 % CI 1.02-1.22). There was no suggestion for heterogeneity across cohorts (P heterogeneity > 0.05). The combined data from >150,000 individuals 60 years and older suggest that higher education may contribute to lower hip fracture risk. Furthermore, this risk may be higher among individuals living alone, especially among the age group 60-69 years, when compared to those being married/cohabiting.

  16. The Role of Radiographs and Office Visits in the Follow-Up of Healed Intertrochanteric Hip Fractures: An Economic Analysis.

    Science.gov (United States)

    Kempegowda, Harish; Richard, Raveesh; Borade, Amrut; Tawari, Akhil; Howenstein, Abby M; Kubiak, Erik N; Suk, Michael; Horwitz, Daniel S

    2016-12-01

    The purpose of this study was to evaluate the role and the necessity of radiographs and office visits obtained during follow-up of intertrochanteric hip injuries. Retrospective study. Two level I trauma centers. Four hundred sixty-five elderly patients who were surgically treated for an intertrochanteric fracture of the femur at 2 level I trauma centers between January 2009 and August 2014 were retrospectively identified from orthopaedic trauma databases. Analysis of all healed intertrochanteric hip fractures, including demographic characteristics, quality of reduction, time of healing, number of office visits, number of radiographs obtained, and each radiograph for fracture alignment, implant position or any pathological changes. The surgical fixation of 465 fractures included 155 short nails (33%), 232 long nails (50%), 69 sliding hip screw devices (15%), 7 trochanteric stabilizing plates (1.5%), and 2 proximal femur locking plates (0.5%). The average fracture healing time was 12.8 weeks and the average follow-up was 81.2 weeks. Radiographs of any patient obtained after the fracture had healed did not reveal any changes, including fracture alignment or implant position and hardware failure. In 9 patients, pathological changes, including arthritis (3), avascular necrosis (3), and ectopic ossification (3) were noted. The average number of elective office visits and radiographs obtained after the fracture had healed were 2.8 (range: 1-8) and 2.6 (range: 1-8), respectively. According to Medicare payments to the institution, these radiographs and office visits account for a direct cost of $360.81 and $192, respectively, per patient. The current study strongly suggests that there is a negligible role for radiographs and office visits during the follow-up of a well-healed hip fracture when there is documented evidence of radiographic and clinical healing with acceptable fracture alignment and implant position. Implementation of this simple measure will help in reducing

  17. The Bristol Hip View: Its Role in the Diagnosis and Surgical Planning and Occult Fracture Diagnosis for Proximal Femoral Fractures

    Directory of Open Access Journals (Sweden)

    J. Harding

    2013-01-01

    Full Text Available Aim. To evaluate whether a modified radiographic view of the femoral neck improves the diagnosis of occult proximal femoral. Materials and Methods. Prospective study of patients presenting with clinically suspected proximal femoral fractures or who underwent traditional plain radiographic views and the Bristol hip view (a 30-degree angled projection. Six blinded independent observers assessed the images for presence of a fracture, anatomical level, and displacement. Results. 166 consecutive patients presenting with the clinical diagnosis of a proximal femoral fracture, of which 61 sustained a fracture. Six of these were deemed occult due to negative plain and had proven fractures on subsequent cross-sectional imaging. The Bristol hip view demonstrated five of these six fractures. It performed better than the traditional lateral hip view to identify the injury. The Bristol hip view predicted correctly the fracture type and displacement in all cases and missed only one of the occult fractures. Conclusion. The Bristol hip view is more sensitive and clearer than a lateral projection for patients. It adds useful diagnostic information and performs better than the traditional views in occult fractures. Its use may prevent the need for further cross sectional imaging and subsequent surgical delay.

  18. USING TRABECULAR METAL AUGMENTS FOR TOTAL HIP REPLACEMENT IN PATIENTS AFTER ACETABULAR FRACTURES

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2011-01-01

    Full Text Available The authors presented the experience of treatment of two patients with hip arthritis after acetabular fracture. Both patients were treated with total hip replacement. During the operation, to manage posterior-superior bone defects of the acetabulum, augments of trabecular metal were used. Pain and limitation of motions in hip were indications for operative treatment. After a year of follow up there was no pain in hip; also recovery of motion and improved quality of life were observed.

  19. Incidence and direct hospitalisation costs of hip fractures in Vilnius, capital of Lithuania, in 2010

    Directory of Open Access Journals (Sweden)

    Tamulaitiene Marija

    2012-07-01

    Full Text Available Abstract Background Few epidemiological data on hip fractures were previously available in Lithuania. The aim of this study was to estimate the incidence and hospital costs of hip fractures in Vilnius in 2010. Methods Data were collected from the medical charts of all patients admitted to hospitals in Vilnius (population, 548,835 due to new low-energy trauma hip fracture, during 2010. The estimated costs included ambulance transportation and continuous hospitalisation immediately after a fracture, which are covered by the Lithuanian healthcare system. Results The incidence of new low-energy trauma hip fractures was 252 (308 women and 160 men per 100,000 inhabitants of Vilnius aged 50-years or more. There was an exponential increase in the incidence with increasing age. The overall estimated cost of hip fractures in Vilnius was 1,114,292 EUR for the year 2010. The greatest part of the expenditure was accounted for by fractures in individuals aged 65-years and over. The mean cost per case was 2,526.74 EUR, and cost varied depending on the treatment type. Hip replacement did not affect the overall mean costs of hip fracture. The majority of costs were incurred for acute (53% and long-term care (35% hospital stays, while medical rehabilitation accounted for only 12% of the overall cost. The costs of hip fracture were somewhat lower than those found in other European countries. Conclusion The data on incidence and costs of hip fractures will help to assess the importance of interventions to reduce the number of fractures and associated costs.

  20. Radiographic and clinical analysis of cementless acetabular fixation in total hip arthroplasty

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hui; PEI Fu-xing; YANG Jing; SHEN Bin; SHI Rui

    2005-01-01

    Objective: To investigate the factors affecting the fixation, loosening and therapeutic effect of cementless acetabular prosthesis through following up the patients with total hip arthroplasty clinically and radiographically.Methods: From February 1998 to May 1999, 139 patients (148 hips) underwent total hip arthroplasty with cementless acetabular prosthesis in our department. In this study, the clinical therapeutic effect and the anteroposterior radiographs of the pelvis and anteroposterior and lateral radiographs of the hips of 109 patients (116 hips) made before operation, at 1 week, 3, 6, and 12 months after operation and annually thereafter were analyzed retrospectively. The clinical therapeutic effects were evaluated with Harris hip score. Radiographs were used to observe the position of prostheses and the bone changes around the implant, and to measure the wearing speed and direction of the acetabular cup. All evaluations were made by an independent examiner who did not participate in the operation. The patients were followed up for 5-6 years.Results: The mean Harris score was 44 points (range, 10-70 points) before operation, but it increased to 92.4 points (range, 80-100 points) at the latest review after operation, which was significantly higher than that before operation (P<0.05). No acetabular component was revised because of infection or aseptic loosening. And no acetabular component migrated. There was no revision of fixed acetabular component because of pelvic osteolysis secondary to polyethylene wear. The mean linear wear rate was 0.15 mm per year. All the acetabular prostheses were classified as stable on the radiographs.Conclusions: In terms of fixation, total hip arthroplasty with cementless acetabular components was successful. Although there is no aseptic loosening and a low incidence of osteolysis at the latest follow-up evaluation, polyethylene wear cannot be avoided and can lead to expansile osteolysis near the cups. This kind of osteolysis

  1. Clinical analysis of the rap stress stimulator applied for crus fracture after skeletal external fixation.

    Science.gov (United States)

    Zhuang, Ping; Hong, Jiayuan; Chen, Wei; Wu, Jin; Ding, Zhenqi

    2015-06-19

    Open crus fracture is still difficult in clinical treatment because of the delayed fracture union and high rate of nonunion after the operation. A consensus has been reached that mechanical stress can promote fracture healing. We independently developed a stress stimulator, which can provide longitudinal pressure for the fixed fracture end of the lower legs to promote fracture healing. The purpose of this study is to explore the advantages and clinical effect of the rap stress stimulator applied for open crus fracture after skeletal external fixation. One hundred and sixty-five patients (183 limbs) who suffered from open tibia and fibula fracture received skeletal external fixation, of which 108 limbs were treated with the rap stress stimulator after external fixation and 75 limbs were treated with regular functional exercises of muscle contraction and joint activity only. Then the fracture healing time and rate of nonunion were compared between the two groups. The mean fracture healing time and rate of nonunion in the group treated with the rap stress stimulator were 138.27 ±4.45 days and 3.70% respectively, compared to 153.43 ±4.89 days and 10.67% in the group treated without the stimulator. The rap stress stimulator significantly shortened the fracture healing time and reduced the rate of nonunion for treating open tibia and fibula fractures.

  2. Outcomes of Internal Fixation in a Combat Environment

    Science.gov (United States)

    2010-01-01

    postoperative infection, had missed injuries. One was a closed bimalleolar ankle fracture that had the fibula fracture and syndesmosis inter- nally fixed...is to describe the outcomes of fractures that were internally fixed in the combat environment. The records of patients who had internal fixation...analyzed. Forty-seven patients had internal fixation performed on 50 fractures in a combat theater hospital. Hip, forearm, and ankle fractures made up the

  3. Percutaneous Screw Fixation of Crescent Fracture-Dislocation of the Sacroiliac Joint.

    Science.gov (United States)

    Shui, Xiaolong; Ying, Xiaozhou; Mao, Chuanwan; Feng, Yongzeng; Chen, Linwei; Kong, Jianzhong; Guo, Xiaoshan; Wang, Gang

    2015-11-01

    Crescent fracture-dislocation of the sacroiliac joint (CFDSIJ) is a type of lateral compression pelvic injury associated with instability. Open reduction and internal fixation is a traditional treatment of CFDSIJ. However, a minimally invasive method has never been reported. The purpose of this study was to assess the outcome of closed reduction and percutaneous fixation for different types of CFDSIJ and present their clinical outcome. The authors reviewed 117 patients diagnosed with CFDSIJ between July 2003 and July 2013. Closed reduction and percutaneous fixation was performed in 73 patients. Treatment selection was based on Day's fracture classification. For type I fractures, fixation perpendicular to the fracture line were performed. For type II fractures, crossed fixation was performed. For type III fractures, fixation was performed with iliosacral screws. Forty-four patients were treated by open reduction and plate fixation. Demographics, fracture pattern distribution, blood loss, incision lengths, revision surgeries, radiological results, and functional scores were compared. All 117 patients were followed for more than 6 months (mean, 14 months [range, 6-24 months]). Blood loss, extensive exposure, duration of posterior ring surgery, duration of hospital stay, and infection rates were lower in the closed group (P<.01). Patients in the closed group achieved better functional performance (P<.01). There were no significant differences in reduction quality (P=.32), revision surgery rates (P=.27), and iatrogenic neurologic injuries (P=.2) between the 2 groups. The authors' results indicate that closed reduction and percutaneous fixation is a safe and effective surgical method for CFDSIJ. Copyright 2015, SLACK Incorporated.

  4. Risk Factors for Hip Fracture in Older Men: The Osteoporotic Fractures in Men Study (MrOS).

    Science.gov (United States)

    Cauley, Jane A; Cawthon, Peggy M; Peters, Katherine E; Cummings, Steven R; Ensrud, Kristine E; Bauer, Douglas C; Taylor, Brent C; Shikany, James M; Hoffman, Andrew R; Lane, Nancy E; Kado, Deborah M; Stefanick, Marcia L; Orwoll, Eric S

    2016-10-01

    Almost 30% of hip fractures occur in men; the mortality, morbidity, and loss of independence after hip fractures are greater in men than in women. To comprehensively evaluate risk factors for hip fracture in older men, we performed a prospective study of 5994 men, primarily white, age 65+ years recruited at six US clinical centers. During a mean of 8.6 years of 97% complete follow-up, 178 men experienced incident hip fractures. Information on risk factors including femoral neck bone mineral density (FNBMD) was obtained at the baseline visit. Cox proportional hazards models were used to calculate the hazard ratio (HR) with 95% confidence intervals; Fine and Gray models adjusted for competing mortality risk. Older age (≥75 years), low FNBMD, currently smoking, greater height and height loss since age 25 years, history of fracture, use of tricyclic antidepressants, history of myocardial infarction or angina, hyperthyroidism or Parkinson's disease, lower protein intake, and lower executive function were all associated with an increased hip fracture risk. Further adjustment for competing mortality attenuated HR for smoking, hyperthyroidism, and Parkinson's disease. The incidence rate of hip fracture per 1000 person-years (PY) was greatest in men with FNBMD T-scores hip fracture at rates of 14.52 versus 0.88 per 1000 PY in men age hip fracture. Many of these assessments can easily be incorporated into routine clinical practice and may lead to improved risk stratification. © 2016 American Society for Bone and Mineral Research. © 2016 American Society for Bone and Mineral Research.

  5. FUNCTIONAL OUTCOME OF SURGICAL MANAGEMENT OF ACETABULAR FRACTURES BY INTERNAL FIXATION

    Directory of Open Access Journals (Sweden)

    Sagar

    2015-06-01

    Full Text Available BACKGROUND: The treatment of acetabular fractures has seen major advances in the field of orthopaedic traumatology. Conservative treatment of acetabular fractures leads to poor results. Newer diagnostic tools like the Computed Tomography (CT scan help in analyzing the three dimensional disturbance in the normal anatomy and plan the surgical management accordingly. In recent years operative treatment has become the treat ment of choice in the management of acetabular fractures as precise anatomical reduction with adequate internal fixation can be attained. OBJECTIVES : To evaluate the functional outcome of operatively managed acetabular fractures , and assess the efficacy of operative fixation of acetabular fractures , and also study the complications of operative fixation of acetabular fractures. MATERIALS AND METHODS: Fifty five patients (49 male & six female admitted to Sanjay Gandhi Institute of Trauma and Orthopaedics wi th acetabular fractures underwent open reduction and internal fixation. All patients were evaluated with Matta et al score with a minimum of follow up of six months. RESULTS: There were 24 (43.6% patients with bicolumnar fractures , 15(27.3% had posterior column fractures , 10(18.1% had posterior wall fractures , five (9.1% had transverse fractures , and one (1.8% patient had an anterior column fracture. Full weight bearing was attained in thirty five (63.6% patients in 16 weeks and in twenty (36.4% pati ents after 16 weeks. Forty five (81.8% patients were free of complications. According to Matta et al score 27(49.1% had excellent , 15(27.3% had good , nine (16.4% had fair , and four (7.3% had poor results. CONCLUSION: Open reduction and internal fixati on of acetabular fractures is a reliable technique , minimizes healing time and provides congruent joint reduction. Operative treatment of acetabular fractures results in predictable union and good clinical results with a low rate of complications.

  6. Dynamic long leg casting fixation for treating 12- to 18-month-old infants with developmental dysplasia of the hip.

    Science.gov (United States)

    Cai, Zhencun; Li, Lianyong; Zhang, Lijun; Ji, Shijun; Zhao, Qun

    2017-02-01

    Objective To evaluate the effect of dynamic long leg casting in paediatric patients with developmental dysplasia of hip (DDH) diagnosed at 12-18 months. Methods The adductor tenotomy, closed reduction, and dynamic long leg casting method was adopted to treat paediatric patients with DDH. The hips were divided into four groups according to the Tonnis radiographic dislocation classification. Groups were also classified according to the baseline acetabular index (AI): 30°-35°, 36°-40°, and > 40°. The outcomes of the reductions were evaluated according to McKay's hip function criteria and Severin's radiological criteria. Results A total of 246 patients (339 hips) had complete follow-up data. After 3 months of orthosis fixation, the results were satisfactory in 264 hips (77.88%). Hip function was rated as 'excellent' or 'good' in 43 of 51 (84.31%) Tonnis type 1 hips, 125 of 155 (80.65%) type 2 hips, 70 of 90 (77.78%) type 3 hips, and 34 of 43 (79.07%) type 4 hips. The higher the baseline AI, the lower the rates of 'excellent' and 'good' hip function. Favourable radiological results (Severin types I and II) were found in 266 of 339 (78.47) hips. Conclusions Dynamic long leg casting is an effective method for treating patients with DDH aged 12-18 months at diagnosis.

  7. Most patients regain prefracture basic mobility after hip fracture surgery in a fast-track programme

    DEFF Research Database (Denmark)

    Kristensen, Morten Tange; Kehlet, Henrik

    2012-01-01

    Treatment of patients with hip fracture has improved over the past decade. Still, some patients do not regain independent mobility within their primary hospital stay even if they follow a multimodal fast-track surgical programme. The aim of the present article was to examine the validity...... of the preliminary prefracture New Mobility Score (NMS), age and fracture type as independent predictors of in-hospital outcome after hip fracture surgery....

  8. Improving community ambulation after hip fracture: protocol for a randomised, controlled trial

    Science.gov (United States)

    Orwig, D; Mangione, KK; Baumgarten, M; Terrin, M; Fortinsky, R; Kenny, AM; Gruber-Baldini, AL; Beamer, B; Tosteson, ANA; Shardell, M; Magder, L; Binder, E; Koval, K; Resnick, B; Craik, RL; Magaziner, J

    2017-01-01

    Introduction After a hip fracture in older persons, significant disability often remains; dependency in functional activities commonly persists beyond 3 months after surgery. Endurance, dynamic balance, quadriceps strength, and function are compromised, and contribute to an inability to walk independently in the community. In the United States, people aged 65 years and older are eligible to receive Medicare funding for physiotherapy for a limited time after a hip fracture. A goal of outpatient physiotherapy is independent and safe household ambulation 2 to 3 months after surgery. Current Medicare-reimbursed post-hip-fracture rehabilitation fails to return many patients to pre-fracture levels of function. Interventions delivered in the home after usual hip fracture physiotherapy has ended could promote higher levels of functional independence in these frail and older adult patients. Primary objective To evaluate the effect of a specific multicomponent physiotherapy intervention (PUSH), compared with a non-specific multi-component control physiotherapy intervention (PULSE), on the ability to ambulate independently in the community 16 weeks after randomisation. Design Parallel, two-group randomised multicentre trial of 210 older adults with a hip fracture assessed at baseline and 16 weeks after randomisation, and at 40 weeks after randomisation for a subset of approximately 150 participants. Participants and setting A total of 210 hip fracture patients are being enrolled at three clinical sites and randomised up to 26 weeks after admission. Study inclusion criteria are: closed, non-pathologic, minimal trauma hip fracture with surgical fixation; aged ≥ 60 years at the time of randomisation; community residing at the time of fracture and randomisation; ambulating without human assistance 2 months prior to fracture; and being unable to walk at least 300 m in 6 minutes at baseline. Participants are ineligible if the interventions are deemed to be unsafe or unfeasible

  9. Coffee, tea, and the risk of hip fracture: a meta-analysis.

    Science.gov (United States)

    Sheng, J; Qu, X; Zhang, X; Zhai, Z; Li, H; Liu, X; Li, H; Liu, G; Zhu, Z; Hao, Y; Qin, A; Dai, K

    2014-01-01

    The present meta-analysis shows no clear association between coffee consumption and the risk of hip fractures. There was a nonlinear association between tea consumption and the risk of hip fracture. Compared to no tea consumption, drinking 1-4 cups of tea daily was associated with a lower risk of hip fracture. Prospective cohort and case-control studies have suggested that coffee and tea consumption may be associated with the risk of hip fracture; the results have, however, been inconsistent. We conducted a meta-analysis to assess the association between coffee and tea consumption and the risk of hip fracture. We performed systematic searches using MEDLINE, EMBASE, and OVID until February 20, 2013, without limits of language or publication year. Relative risks (RRs) with 95% confidence intervals (CI) were derived using random-effects models throughout all analyses. We conducted categorical, dose-response, heterogeneity, publication bias, and subgroup analyses. Our study was based on 195,992 individuals with 9,958 cases of hip fractures from 14 studies, including six cohort and eight case-control studies. The pooled RRs of hip fractures for the highest vs. the lowest categories of coffee and tea consumption were 0.94 (95% CI 0.71-1.17) and 0.84 (95% CI 0.66-1.02), respectively. For the dose-response analysis, we found evidence of a nonlinear association between tea consumption and the risk of hip fracture (p(nonlinearity) risk of hip fracture by 28% (0.72; 95% CI 0.56-0.88 for 1-2 cups/day), 37% (0.63; 95% CI 0.32-0.94 for 2-3 cups/day), and 21% (0.79; 95% CI 0.62-0.96 for 3-4 cups/day). We found no significant association between coffee consumption and the risk of hip fracture. A nonlinear association emerged between tea consumption and the risk of hip fracture; individuals drinking 1-4 cups of tea per day exhibited a lower risk of hip fractures than those who drank no tea. The association between 5 daily cups of tea, or more, and hip fracture risk should be

  10. Does hip osteoarthritis have a protective effect against proximal femoral fractures? A retrospective study.

    Science.gov (United States)

    Calderazzi, Filippo; Groppi, Giulia; Ricotta, Agostino; Ceccarelli, Francesco

    2014-01-01

    The inverse relationship between proximal femoral fracture incidence and hip osteoarthritis remains controversial. However, femoral neck fractures rarely occur in patients with hip osteoarthritis, suggesting a protective effect of osteoarthritis. We sought to determine if the severity of osteoarthritis influenced fracture type. We examined the radiographs of 190 consecutive patients treated at our institution after hip trauma. They were divided into three groups according to the outcome of the trauma: femoral neck fracture; trochanteric fracture; and no fracture. We then analysed the severity of osteoarthritis within these groups. No relationship between the grade of hip osteoarthritis and the presence of a proximal femoral fracture was found. However, the grade of osteoarthritis was related both to the outcome of the trauma (posteoarthritis of the hip had a three-fold increased likelihood of trochanteric fracture compared to femoral neck fracture. Osteoarthritis does not protect against proximal femoral fractures, but strongly affects the location of the fracture in the proximal femur, increasing the possibility of a trochanteric location.

  11. Bone bruise, lipohemarthrosis, and joint effusion in CT of non-displaced hip fracture

    Energy Technology Data Exchange (ETDEWEB)

    Geijer, Mats (Center for Medical Imaging and Physiology, Skaane University Hospital, Lund University, Lund (Sweden)), Email: mats@geijer.info; Dunker, Dennis; Collin, David; Goethlin, Jan H. (Department of Radiology, Sahlgrenska University Hospital, Moelndal (Sweden))

    2012-03-15

    Background. A suspected occult hip fracture after normal radiography is not uncommon in an elderly person after a fall. Despite a lack of robust validation in the literature, computed tomography (CT) is often used as secondary imaging. Purpose. To assess the frequency and clinical utility of non-cortical skeletal and soft tissue lesions as ancillary fracture signs in CT diagnosis of occult hip fractures. Material and Methods. All fracture signs (cortical and trabecular fractures, bone bruise, joint effusion, and lipohemarthrosis) were recorded in 231 hip low-energy trauma cases with CT performed after normal or equivocal radiography in two trauma centers. Results. There were no fracture signs in 110 patients. Twelve of these had a joint effusion. In 121 patients with 46 cervical hip fractures and 75 trochanteric fractures one or more fracture signs were present. Cortical fractures were found in 115 patients. Bone bruise was found in 119 patients, joint effusion in 35, and lipohemarthrosis in 20 patients. Conclusion. Ancillary signs such as bone bruise and lipohemarthrosis can strengthen and sometimes indicate the diagnosis in CT of occult hip fractures. Joint effusion is a non-specific sign

  12. Bone bruise, lipohemarthrosis, and joint effusion in CT of non-displaced hip fracture.

    Science.gov (United States)

    Geijer, Mats; Dunker, Dennis; Collin, David; Göthlin, Jan H

    2012-03-01

    A suspected occult hip fracture after normal radiography is not uncommon in an elderly person after a fall. Despite a lack of robust validation in the literature, computed tomography (CT) is often used as secondary imaging. To assess the frequency and clinical utility of non-cortical skeletal and soft tissue lesions as ancillary fracture signs in CT diagnosis of occult hip fractures. All fracture signs (cortical and trabecular fractures, bone bruise, joint effusion, and lipohemarthrosis) were recorded in 231 hip low-energy trauma cases with CT performed after normal or equivocal radiography in two trauma centers. There were no fracture signs in 110 patients. Twelve of these had a joint effusion. In 121 patients with 46 cervical hip fractures and 75 trochanteric fractures one or more fracture signs were present. Cortical fractures were found in 115 patients. Bone bruise was found in 119 patients, joint effusion in 35, and lipohemarthrosis in 20 patients. Ancillary signs such as bone bruise and lipohemarthrosis can strengthen and sometimes indicate the diagnosis in CT of occult hip fractures. Joint effusion is a non-specific sign.

  13. Comparison of hybrid fixation versus dual intramedullary nailing fixation for forearm fractures in older children: Case-control study.

    Science.gov (United States)

    Feng, Yongzeng; Shui, Xiaolong; Wang, Jianshun; Cai, Leyi; Wang, Gang; Hong, Jianjun

    2016-06-01

    The aim of the present study was to compare the clinical outcomes of hybrid fixation using elastic stable intramedullary nailing (ESIN) for the radius and plate screw fixation for the ulna (Hybrid group) with dual ESIN fixation (D-ESIN group) for both-bone forearm fractures in children between 10 and 16 years of age. Fifty patients with both-bone forearm fractures (28 patients in the Hybrid group and 22 patients in the D-ESIN group) were reviewed. Functional outcomes were evaluated according to the criteria of Price et al. Radiological results were assessed by fracture union at three and six months and bone union time. Postoperative complications were also recorded. The times of fluoroscopy intraoperatively and duration of immobilization postoperatively were significantly lower in the Hybrid group (P < 0.05). The union rate of the ulna at three months postoperatively in the hybrid group was significantly higher than that in the D-ESIN group (P < 0.05). The average time of bone union was significantly shorter in the hybrid group than that in the D-ESIN group (P < 0.05). There were no differences according to the satisfactory rate and degree, the major and minor complications between the groups. Hybrid fixation is superior in terms of the times of fluoroscopy intraoperatively, duration of immobilization postoperatively, delayed union rate of the ulna and the average time of bone union. Therefore, hybrid fixation is an alternative treatment for both-bone forearm fractures in children between 10 and 16 years of age. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  14. Sextant percutaneous pedicle screw fixation for correcting single-segment thoracolumbar fractures

    Institute of Scientific and Technical Information of China (English)

    Ming Jiang-hua; Zheng Hui-feng; Zhao Qi; Chen Qing; Wang Gang

    2014-01-01

    BACKGROUND:Though the effects of conservative or traditional open reduction and internal fixation in the treatment of thoracolumbar fractures are reliable and satisfactory for most cases, two methods also have shortages. Minimal-invasive percutaneous pedicle screw system provides a new available method. OBJECTIVE:To investigate the clinical effect of Sextant percutaneous pedicle screw system in the treatment of thoracolumbar fractures. METHODS:A total of 55 patients, who had undergone percutaneous pedicle screw fixation using Sextant system (25 patients) or traditional open internal fixation (30 patients) for single-level vertebral body compression fractures in Department of Orthopedics of Renmin Hospital of Wuhan University from February 2011 to January 2013, were enrol ed in this study. RESULTS AND CONCLUSION:Except two patients in traditional open internal fixation group were lost after discharge, al other patients were fol owed up for 8-14 months. Operative time, intraoperative blood loss, postoperative drainage amount and hospital day were better in percutaneous pedicle screw fixation group than in the traditional open internal fixation group (P0.05). The results show that percutaneous pedicle screw fixation using Sextant system has a satisfactory outcome in the treatment of thoracolumbar fractures. However, obeying indication strictly is very important for clinical application.

  15. Long-term survival and risk factors for failure of the native hip joint after operatively treated displaced acetabular fractures.

    Science.gov (United States)

    Clarke-Jenssen, J; Røise, O; Storeggen, S A Ø; Madsen, J E

    2017-06-01

    Our aim in this study was to describe the long-term survival of the native hip joint after open reduction and internal fixation of a displaced fracture of the acetabulum. We also present long-term clinical outcomes and risk factors associated with a poor outcome. A total of 285 patients underwent surgery for a displaced acetabular fracture between 1993 and 2005. For the survival analysis 253 were included, there were 197 men and 56 women with a mean age of 42 years (12 to 78). The mean follow-up of 11 years (1 to 20) was identified from our pelvic fracture registry. There were 99 elementary and 154 associated fracture types. For the long-term clinical follow-up, 192 patients with complete data were included. Their mean age was 40 years (13 to 78) with a mean follow-up of 12 years (5 to 20). Injury to the femoral head and acetabular impaction were assessed with CT scans and patients with an ipsilateral fracture of the femoral head were excluded. A total of 36 patients underwent total hip arthroplasty (THA). The overall ten-year survival of the hip joint was 86% (95% confidence interval (CI) 81% to 90%) and the 20-year survival was 82% (95% CI 76% to 87%). Injury to the femoral head and acetabular impaction were the strongest predictors of failure, with the long-term survival rate falling towards 50% in these patients. The survival fell to 0% at three years when both these risk factors were present in patients aged > 60 years. The long-term survival of the native hip joint after acetabular fractures was good, but the presence of injury to the femoral head and acetabular impaction proved to be strong predictors of failure, especially in patients aged > 60 years. These patients may be better treated with a combination of open reduction and internal fixation and primary arthroplasty. Cite this article: Bone Joint J 2017;99-B:834-40. ©2017 The British Editorial Society of Bone & Joint Surgery.

  16. A Comparison of Screw Fixation and Suture-Button Fixation in a Syndesmosis Injury in an Ankle Fracture.

    Science.gov (United States)

    Kim, Jung-Han; Gwak, Heui-Chul; Lee, Chang-Rack; Choo, Hye-Jeung; Kim, Jeon-Gyo; Kim, Dae-Yoo

    2016-01-01

    The present study compared the quality of reduction and the clinical assessment between screw fixation and suture-button fixation with an ankle fracture accompanied by syndesmosis injury. We studied the clinical and radiologic findings 1 year postoperatively through retrospective examination of 24 patients who had undergone screw fixation from January 2011 to December 2012 and prospective examination of 20 patients who had undergone suture button fixation from January 2013 to May 2014. Regarding the tibiofibular clear space, tibiofibular overlap, and medial clear space, the screw fixation group had improvement from a preoperative mean of 6.97 (range 2.79 to 15.81) mm, 4.43 (range 0 to 7.87) mm, 7.90 (range 4.24 to 19.50) mm to a postoperative mean of 4.95 (range 2.72 to 9.08) mm, 6.29 (range 0 to 10.37) mm, and 4.32 (range 1.98 to 6.57) mm, respectively. The corresponding improvement for the suture-button fixation group was from a preoperative mean of 6.65 (range 3.94 to 13.73) mm, 5.39 (range 0 to 9.44) mm, 7.27 (range 4.04 to 16.00) mm to a postoperative mean of 5.15 (range 2.93 to 7.30) mm, 7.21 (range 2.15 to 10.30) mm, and 4.25 (range 2.97 to 5.71) mm. No statistically significant difference was found between the 2 techniques. Both suture-button and metal screw fixation are effective treatment methods for an ankle fracture accompanied by syndesmosis injury. However, a long-term and prospective analysis is needed. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Osteosynthesis of ununited femoral neck fracture by internal fixation combined with iliac crest bone chips and muscle pedicle bone grafting

    Directory of Open Access Journals (Sweden)

    D D Baksi

    2016-01-01

    , cannulated hip screw fixation, iliac crest bone chips and quadratus femoris MPBG. Results: The mean followup is 12.5 years (range 3-35. The union of fractures occurred in 202 (82.8%, delayed union in 18 (7.3%, and established nonunion in 24 (9.8% patients. Full weight bearing was permitted at 16-22 weeks after union of fractures. Mean Harris hip score at the longest followup was 85.5. Among the complications, superficial wound infection occurred in 20 (8.2%, deep infection in seven (2.9%, and coxa vara in 39 (16% patients. Preoperative radiodensity of femoral head disappeared mostly after the union of fracture whereas fresh radiodensity of femoral head appeared in 20 (8% patients; nine (45% of them developed segmental collapse. Conclusion: Ununited femoral neck fractureis characterized by absorption of femoral neck, posterior cortical defect, smoothening and overriding of fracture surfaces with intervening fibrous tissues associated with or without AVN of femoral head. The above method of osteosynthesis rectified the above pathology and provided satisfactory results with union of fractures in 90.1% patients at long term followup.

  18. Management of extra-articular fractures of the distal tibia: intramedullary nailing versus plate fixation.

    Science.gov (United States)

    Casstevens, Chris; Le, Toan; Archdeacon, Michael T; Wyrick, John D

    2012-11-01

    Intramedullary nailing and plate fixation represent two viable approaches to internal fixation of extra-articular fractures of the distal tibia. Although both techniques have demonstrated success in maintaining reduction and promoting stable union, they possess distinct advantages and disadvantages that require careful consideration during surgical planning. Differences in soft-tissue health and construct stability must be considered when choosing between intramedullary nailing and plating of the distal tibia. Recent advances in intramedullary nail design and plate-and-screw fixation systems have further increased the options for management of these fractures. Current evidence supports careful consideration of the risk of soft-tissue complications, residual knee pain, and fracture malalignment in the context of patient and injury characteristics in the selection of the optimal method of fixation.

  19. Posterior acetabular column and quadrilateral plate fractures: fixation with tension band principles.

    Science.gov (United States)

    Aly, Tarek A; Hamed, Hany

    2013-07-01

    Acetabular fractures can be classified into 5 simple and 5 associated fracture patterns. A significant amount of variation and complexity exists in these fractures patterns. Fractures of the posterior wall are the most common acetabular fractures. Comminution of the quadrilateral plate adds to fracture instability, and more rigid and stable internal fixation is mandatory. The goal of this study was to assess the results of reconstruction of comminuted posterior wall fractures of the acetabulum associated with quadrilateral plate fractures using the tension band technique. Twelve patients (9 men and 3 women) were included in the study. Mean patient age was 38.6 years (range, 24-47 years). Minimum follow-up was more than 2 years postoperatively. Reconstruction of the fracture included anatomic reduction of the fracture and fixation with a buttress plate for the posterior column and a prebent one-third tubular plate for the quadrilateral plate fracture. Clinical results were excellent in 58% of patients and good in 17% of patients. Radiologic results were excellent in 50% of patients and good in 17% of patients. Radiologically, based on the fracture gap postoperatively, 8 (66%) patients showed anatomic reduction, 2 (17%) showed good reduction, and 2 (17%) showed poor reduction. The study confirms that this method of reconstruction facilitates accurate and firm reduction of displaced posterior wall fractures of the acetabulum.

  20. Comparisons of external fixator combined with limited internal fixation and open reduction and internal fixation for Sanders type 2 calcaneal fractures: Finite element analysis and clinical outcome.

    Science.gov (United States)

    Pan, M; Chai, L; Xue, F; Ding, L; Tang, G; Lv, B

    2017-07-01

    The aim of this study was to compare the biomechanical stability and clinical outcome of external fixator combined with limited internal fixation (EFLIF) and open reduction and internal fixation (ORIF) in treating Sanders type 2 calcaneal fractures. Two types of fixation systems were selected for finite element analysis and a dual cohort study. Two fixation systems were simulated to fix the fracture in a finite element model. The relative displacement and stress distribution were analysed and compared. A total of 71 consecutive patients with closed Sanders type 2 calcaneal fractures were enrolled and divided into two groups according to the treatment to which they chose: the EFLIF group and the ORIF group. The radiological and clinical outcomes were evaluated and compared. The relative displacement of the EFLIF was less than that of the plate (0.1363 mm to 0.1808 mm). The highest von Mises stress value on the plate was 33% higher than that on the EFLIF. A normal restoration of the Böhler angle was achieved in both groups. No significant difference was found in the clinical outcome on the American Orthopedic Foot and Ankle Society Ankle Hindfoot Scale, or on the Visual Analogue Scale between the two groups (p > 0.05). Wound complications were more common in those who were treated with ORIF (p = 0.028). Both EFLIF and ORIF systems were tested to 160 N without failure, showing the new construct to be mechanically safe to use. Both EFLIF and ORIF could be effective in treating Sanders type 2 calcaneal fractures. The EFLIF may be superior to ORIF in achieving biomechanical stability and less blood loss, shorter surgical time and hospital stay, and fewer wound complications.Cite this article: M. Pan, L. Chai, F. Xue, L. Ding, G. Tang, B. Lv. Comparisons of external fixator combined with limited internal fixation and open reduction and internal fixation for Sanders type 2 calcaneal fractures: Finite element analysis and clinical outcome. Bone Joint Res 2017

  1. Fixation of multifragmentary patella fractures using a bilateral fixed-angle plate.

    Science.gov (United States)

    Thelen, Simon; Betsch, Marcel; Schneppendahl, Johannes; Grassmann, Jan; Hakimi, Mohssen; Eichler, Christian; Windolf, Joachim; Wild, Michael

    2013-11-01

    This biomechanical study is the first to compare 3 fixation methods-bilateral fixed-angle plate, modified anterior tension wiring, and cannulated lag screws with anterior tension wiring-in multifragmentary distal patella fractures. A T-shaped 3-part fracture simulating a multifragmentary articular distal patella fracture (AO/OTA 34-C2.2) was created in 18 human cadaver knee specimens. Three groups were created using homogenous ages and bone mineral densities based on the fixation method received. Repetitive testing over 100 cycles was performed by moving the knee against gravity from 90° flexion to full extension. Failure was defined as fracture displacement greater than 2 mm. In all patellae using fixed-angle plates, an anatomical fracture reduction could be maintained throughout cyclic testing, whereas anterior tension wiring and lag screws with tension wiring showed significant fracture displacement after 100 cycles, with mean fracture gaps of 2.0±1.3 and 1.9±1.6 mm, respectively. The differences in fracture gaps between the fixed-angle plate group and the other 2 groups were statistically significant. In both groups using tension wiring, half of the constructs (3 of 6 in each group) failed due to a fracture displacement greater than 2 mm. The bilateral fixed-angle plate was the only fixation method that sustainably stabilized a multifragmentary articular distal patella fracture during cyclic loading when compared with modified anterior tension wiring and cannulated lag screws with anterior tension wiring.

  2. Management of the proximal tibia fractures by mini external fixation: A case series of 30 cases

    Directory of Open Access Journals (Sweden)

    Samar K Biswas

    2014-01-01

    Full Text Available Background: Management of high velocity trauma is a challenging problem because of morbidity of trauma and sometime residual problems of failure of proper healing of fractures with the restriction of movements of knee, shortening, and added risk of compartment syndrome in the proximal tibia fracture. There is always risk of post-operative infection and infected non-union in extensive open surgical procedure and internal fixation. Hence, there is always look out for the middle path procedure for a solution to the above said problems with the added advantage of less hospital stay and early return to work by minimal invasive procedure and stabilization of fracture reduction by multiple K-wire fixation with a frame applied externally. Stabilization of fracture with reduced pain allows early movements of neighbouring joint knee and ankle; hence, reduces the chances of fracture diseases. With this we have been stimulated to take-up the study of managing the proximal tibia fracture by mini external fixator. Aim: The aim of this study was to manage proximal tibia fractures by mini external fixator and evaluate the results and efficacy of this method. Material and Method: A total of 30 patients having proximal tibial fractures admitted at our center between 2008 and 2010 were taken and the procedure carried out was closed manipulative reduction and stabilization with mini external fixator. All acute proximal tibia fractures including tibial plateau fractures above 17 years of age of either sex were included in the study. Fracture more than 3 weeks old were excluded from the study. Result: Out of 30 cases 13 were excellent, 14 cases good, and 3 showed fair. It was found that type 5 and 6 of Schatzker′s classification have lesser outcome type of fractures Conclusion: We have found that management of the proximal tibia fractures by mini external fixation method has a better outcome. Early mobilization of knee in the proximal tibia fractures after

  3. Geographic variation in secondary fracture prevention after a hip fracture during 1999-2013: a UK study.

    Science.gov (United States)

    Shah, A; Prieto-Alhambra, D; Hawley, S; Delmestri, A; Lippett, J; Cooper, C; Judge, A; Javaid, M K

    2017-01-01

    Fragility fractures of the hip have a major impact on the lives of patients and their families. This study highlights significant geographical variation in secondary fracture prevention with even the highest performing regions failing the majority of patients despite robust evidence supporting the benefits of diagnosis and treatment. The purpose of the study is to describe the geographic variation in anti-osteoporosis drug therapy prescriptions before and after a hip fracture during 1999-2013 in the UK. We used primary care data (Clinical Practice Research Datalink) to identify patients with a hip fracture and primary care prescriptions of any anti-osteoporosis drugs prior to the index hip fracture and up to 5 years after. Geographic variations in prescribing before and after availability of generic oral bisphosphonates were analysed. Multivariable logistic regression models were adjusted for gender, age and body mass index (BMI). Thirteen thousand sixty-nine patients (76 % female) diagnosed with a hip fracture during 1999-2013 were identified. Eleven per cent had any anti-osteoporosis drug prescription in the 6 months prior to the index hip fracture. In the 0-4 months following a hip fracture, 5 % of patients were prescribed anti-osteoporosis drugs in 1999, increasing to 51 % in 2011 and then decreasing to 39 % in 2013. The independent predictors (OR (95 % CI)) of treatment initiation included gender (male 0.42 (0.36-0.49)), BMI (0.98 per kg/m(2) increase (0.97-1.00)) and geographic region (1.29 (0.89-1.87) North East vs. 0.56 (0.43-0.73) South Central region). Geographic differences in prescribing persisted over the 5-year follow-up. If all patients were treated at the rate of the highest performing region, then nationally, an additional 3214 hip fracture patients would be initiated on therapy every year. Significant geographic differences exist in prescribing of anti-osteoporosis drugs after hip fracture despite adjustment for potential confounders

  4. Cephalomedullary fixation for femoral neck/intertrochanteric and ipsilateral shaft fractures: surgical tips and pitfalls

    Institute of Scientific and Technical Information of China (English)

    Kamal Bali; Nitesh Gahlot; Sameer Aggarwal; Vijay Goni

    2013-01-01

    Objective:Surgical management options for femoral shaft fracture and ipsilateral proximal femur fracture vary from single-implant to double-implant fixation.Cephalomedullary fixation in such fractures has relative advantages over other techniques especially because of less soft tissue dissection and immediate postoperative weight beating with accelerated rehabilitation.However,the surgery is technically demanding and there is a paucity of literature describing the surgical techniques for this fixation.The aim of the study was to describe the surgical technique of cephalomedullary fixation for femoral shaft fracture and ipsilateral proximal femur fracture.Methods:Sixteen cases (10 males and 6 females with a mean age of 41.8 years) ofipsilateral proximal femur and shaft fractures were treated by single-stage cephalomedullary fixation at tertiary level trauma center in northern India.The fractures were classified according to AO classification.An intraoperative record of duration of surgery as well as technical challenges unique to each fracture pattern was kept for all the patients.ResuRs:The most common proximal femoral pattern was AO B2.1 observed in 9 of our patients.The AO B2.3 fractures were seen in 4 patients while the AO A1.2 fractures in 3 patients.Four of the AO B2.1 and 2 of the AO B2.3 fractures required open reduction with Watson-Jones approach.The mean operative time was around 78 minutes,which tended to decrease as the surgical experience increased.There was only one case of malreduction,which required revision surgery.Conclusion:Combination of ipsilateral femoral shaft fracture and neck/intertrochanteric fracture is a difficult fracture pattern for trauma surgeons.Cephalomedullary nail is an excellent implant for such fractures but it requires careful insertion to avoid complications.Surgery is technically demanding with a definite learning curve.Nevertheless,a majority of these fractures can be surgically managed by singleimplant cephaiomedullary

  5. Late extensor pollicis longus rupture following plate fixation in Galeazzi fracture dislocation

    Directory of Open Access Journals (Sweden)

    Dhananjaya Sabat

    2014-01-01

    Full Text Available Late rupture of extensor pollicis longus (EPL tendon after Galeazzi fracture dislocation fixation is an unknown entity though it is a well-established complication following distal radius fractures. We report the case of a 55-year old male who presented with late EPL tendon rupture 4 months following internal fixation of Galeazzi fracture dislocation with a Locking Compression Plate (LCP. He was managed with extensor indicis proprius (EIP transfer to restore thumb extension. At 4 years followup, functional result of the transfer was good. We identify possible pitfalls with this particular patient and discuss how to avoid them in future.

  6. Late extensor pollicis longus rupture following plate fixation in Galeazzi fracture dislocation.

    Science.gov (United States)

    Sabat, Dhananjaya; Dabas, Vineet; Dhal, Anil

    2014-07-01

    Late rupture of extensor pollicis longus (EPL) tendon after Galeazzi fracture dislocation fixation is an unknown entity though it is a well-established complication following distal radius fractures. We report the case of a 55-year old male who presented with late EPL tendon rupture 4 months following internal fixation of Galeazzi fracture dislocation with a Locking Compression Plate (LCP). He was managed with extensor indicis proprius (EIP) transfer to restore thumb extension. At 4 years followup, functional result of the transfer was good. We identify possible pitfalls with this particular patient and discuss how to avoid them in future.

  7. Timing of long bone fracture fixation in severe traumatic brain injury.

    Science.gov (United States)

    Jamjoom, Bakur A; Jamjoom, Abdulhakim B

    2012-04-01

    We present a review of the published evidence on the optimal timing for long bone fracture fixation in severe traumatic brain injury (TBI); a matter that remains under debate. Fifteen retrospective articles (level II-3 evidence) were considered suitable for the review. We conclude that the published evidence does not provide a definitive answer to the optimal timing of long bone fracture surgery in severe TBI, and a randomized controlled trial is required. We recommend a safe strategy that combines damage control surgery with a period of monitoring of intracranial pressure, cerebral perfusion pressure, and if available brain tissue oxygen until the patient is considered fit for the fracture fixation.

  8. Adult diaphyseal both-bone forearm fractures: A clinical and biomechanical comparison of four different fixations.

    Science.gov (United States)

    Zhang, X F; Huang, J W; Mao, H X; Chen, W B; Luo, Y

    2016-05-01

    Although there have been a small number of studies reporting single bone fixation of either radius or ulna as well as hybrid fixation, the paucity of data for the hybrid fixation method still remains. Hybrid fixation with plate and IM nailing would achieve good fixation and functional outcome, minimal damage to soft tissues and lower re-fracture risk. Forty cadavers (20 males, 20 females; mean age 68.06, SD 1.58years) were selected in biomechanical study under axial loading, bending loading, and torsional loading. Eighty-seven patients (47 males, 40 females; mean age 38.03±0.88years) were enrolled in the clinical study and randomly received different fixation: both-bone plate fixation or both-bone intramedullary nailing, plate fixation of ulna and intramedullary nailing of radius and intramedullary nailing of ulna and plate fixation of radius. In the biomechanical study, intramedullary nailing of ulna and plate fixation of radius had similar results with that using both-bone plate method under axial, bending and torsional loading (All P>0.05), suggesting the more stable fixation compared with the other two groups (All Pradius showed the lowest incidence of postoperative complications and the best functional recovery outcome comparing with other three groups of patients (Both Pradius showed good stability in biomechanics, fewer complications and better functional clinical outcomes. Level II, prospective randomised study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. A Biomechanical Approach to Assessing Hip Fracture Risk

    Science.gov (United States)

    Ellman, Rachel

    2009-01-01

    Bone loss in microgravity is well documented, but it is difficult to quantify how declines in bone mineral density (BMD) contribute to an astronaut's overall risk of fracture upon return. This study uses a biomechanical approach to assessing hip fracture risk, or Factor of Risk (Phi), which is defined as the ratio of applied load to bone strength. All long-duration NASA astronauts from Expeditions 1-18 were included in this study (n=25), while crewmembers who flew twice (n=2) were treated as separate subjects. Bone strength was estimated based on an empirical relationship between areal BMD at the hip, as measured by DXA, and failure load, as determined by mechanical testing of cadaver femora. Fall load during a sideways fall was calculated from a previously developed biomechanical model, which takes into account body weight, height, gender, and soft tissue thickness overlying the lateral aspect of the hip that serves to attenuate the impact force. While no statistical analyses have been performed yet, preliminary results show that males in this population have a higher FOR than females, with a post- flight Phi of 0.87 and 0.36, respectively. FOR increases 5.1% from preflight to postflight, while only one subject crossed the fracture "threshold" of Phi = 1, for a total of 2 subjects with a postflight Phi > 1. These results suggest that men may be at greater risk for hip fracture due largely in part to their relatively thin soft tissue padding as compared to women, since soft tissue thickness has the highest correlation (R(exp 2)= .53) with FOR of all subject-specific parameters. Future work will investigate changes in FOR during recovery to see if baseline risk levels are restored upon return to 1-g activity. While dual x-ray absorptiometry (DXA) is the most commonly used clinical measure of bone health, it fails to provide compartment-specific information that is useful in assessing changes to bone quality as a result of microgravity exposure. Peripheral

  10. A Biomechanical Approach to Assessing Hip Fracture Risk

    Science.gov (United States)

    Ellman, Rachel

    2009-01-01

    Bone loss in microgravity is well documented, but it is difficult to quantify how declines in bone mineral density (BMD) contribute to an astronaut's overall risk of fracture upon return. This study uses a biomechanical approach to assessing hip fracture risk, or Factor of Risk (Phi), which is defined as the ratio of applied load to bone strength. All long-duration NASA astronauts from Expeditions 1-18 were included in this study (n=25), while crewmembers who flew twice (n=2) were treated as separate subjects. Bone strength was estimated based on an empirical relationship between areal BMD at the hip, as measured by DXA, and failure load, as determined by mechanical testing of cadaver femora. Fall load during a sideways fall was calculated from a previously developed biomechanical model, which takes into account body weight, height, gender, and soft tissue thickness overlying the lateral aspect of the hip that serves to attenuate the impact force. While no statistical analyses have been performed yet, preliminary results show that males in this population have a higher FOR than females, with a post- flight Phi of 0.87 and 0.36, respectively. FOR increases 5.1% from preflight to postflight, while only one subject crossed the fracture "threshold" of Phi = 1, for a total of 2 subjects with a postflight Phi > 1. These results suggest that men may be at greater risk for hip fracture due largely in part to their relatively thin soft tissue padding as compared to women, since soft tissue thickness has the highest correlation (R(exp 2)= .53) with FOR of all subject-specific parameters. Future work will investigate changes in FOR during recovery to see if baseline risk levels are restored upon return to 1-g activity. While dual x-ray absorptiometry (DXA) is the most commonly used clinical measure of bone health, it fails to provide compartment-specific information that is useful in assessing changes to bone quality as a result of microgravity exposure. Peripheral

  11. Predictors of not regaining basic mobility after hip fracture surgery

    DEFF Research Database (Denmark)

    Hulsbæk, Signe; Larsen, Rikke Faebo; Troelsen, Anders

    2015-01-01

    cohort study 274 hip fracture patients were included. Patients with compromised ability to exercise were excluded leaving 167 patients for analysis. Patient demographics, functional level, method of operation, post-operative hemoglobin and the completion of physiotherapy was registered. Basic mobility...... was assessed by the Cumulated Ambulation Score. Multivariate logistic regression was performed. RESULTS: Age >80 years (OR = 7.5), low prefracture functional level (OR = 3.0), not completed the physiotherapy on first post-operative day (OR = 4.6) and hemoglobin ... (OR = 5.8) were significant predictors of not regaining basic mobility within the fifth post-operative day (p values: 0.04 - 80 years (OR = 4.3), prefracture functional level (OR = 7.0) and not completed the physiotherapy...

  12. [Hip fracture, antiplatelet drugs treatment and postoperative complications].

    Science.gov (United States)

    Reguant, F; Martínez, E; Gil, B; Prieto, J C; del Milagro Jiménez, L; Arnau, A; Bosch, J

    2013-11-01

    To assess the incidence of postoperative complications, blood transfusions and survival at one month, in the old patients operated for hip fracture undergoing chronic treatment with antiplatelet drugs. Two hundred twenty three patients operated for hip fracture were studied retrospectively, separated into 3 groups: patients who received acetylsalicylic acid (group I), patients who were given 100mg/day of acetylsalicylic acid or 300mg/day of triflusal (group II) and patients receiving>100mg/day of acetylsalicylic acid, or>300mg/day of triflusal or thienopyridines (group III). Surgery was delayed for 4 days in patients in group III. Demographic, biological, clinical and treatment characteristics, postoperative complications and survival at one month were recorded. Patients in group III were older and sustain worse general health status. Patients with a higher transfusion requirement were those of group II (73.8%) (P=0.192), who also showed a higher percentage of anaemia on admission. Severe cardiovascular complications were experienced by 5.4% of group III patients, 4.8% of group II patients and 2.1% of group I patients. Patients from group III presented a significant amount of respiratory complications (P=0.007). Our results suggest that delaying surgery for 4 days in patients treated with clopidogrel can be associated to an increase in postoperative respiratory complications and severe adverse cardiovascular events, without increasing the tranfusional index, hospital stay, mortality, and without complications related to neuraxial anaesthesia. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  13. Machine Learning Principles Can Improve Hip Fracture Prediction.

    Science.gov (United States)

    Kruse, Christian; Eiken, Pia; Vestergaard, Peter

    2017-04-01

    Apply machine learning principles to predict hip fractures and estimate predictor importance in Dual-energy X-ray absorptiometry (DXA)-scanned men and women. Dual-energy X-ray absorptiometry data from two Danish regions between 1996 and 2006 were combined with national Danish patient data to comprise 4722 women and 717 men with 5 years of follow-up time (original cohort n = 6606 men and women). Twenty-four statistical models were built on 75% of data points through k-5, 5-repeat cross-validation, and then validated on the remaining 25% of data points to calculate area under the curve (AUC) and calibrate probability estimates. The best models were retrained with restricted predictor subsets to estimate the best subsets. For women, bootstrap aggregated flexible discriminant analysis ("bagFDA") performed best with a test AUC of 0.92 [0.89; 0.94] and well-calibrated probabilities following Naïve Bayes adjustments. A "bagFDA" model limited to 11 predictors (among them bone mineral densities (BMD), biochemical glucose measurements, general practitioner and dentist use) achieved a test AUC of 0.91 [0.88; 0.93]. For men, eXtreme Gradient Boosting ("xgbTree") performed best with a test AUC of 0.89 [0.82; 0.95], but with poor calibration in higher probabilities. A ten predictor subset (BMD, biochemical cholesterol and liver function tests, penicillin use and osteoarthritis diagnoses) achieved a test AUC of 0.86 [0.78; 0.94] using an "xgbTree" model. Machine learning can improve hip fracture prediction beyond logistic regression using ensemble models. Compiling data from international cohorts of longer follow-up and performing similar machine learning procedures has the potential to further improve discrimination and calibration.

  14. TO COMPARE FUNCTIONAL OUTCOME, COMPLICATIONS & RESULTS OF OPEN REDUCTION & INTERNAL FIXATION WITH CLOSED REDUCTION & EXTERNAL FIXATION IN VOLAR DISPLACED DISTAL RADIAL FRACTURE

    Directory of Open Access Journals (Sweden)

    Ketan Gupta

    2015-02-01

    Full Text Available Distal radius fractures account for 17% of all fractures in adults. The fracture of the lower end of radius crush the mechanical foundation of man‟s most elegant tool, the hand. No other fracture has a greater potential to devastate hand function. Today, o pen reduction of the fracture with internal fixation and closed reduction of the fracture with external fixation, forms the mainstay of the treatment of an uncomplicated distal end radius fracture in a patient unless specifically contraindicated. AIMS AND OBJECTIVES: To compare functional outcome, complications & results of two commonly used surgical methods; Open reduction & internal fixation with volar placed buttress plate and Closed reduction & external fixation with „Jess fixator‟ and internal fixation with „k - wire‟ in volar displaced distal radial fractures. MATERIALS AND METHODS : Total 30 cases were included in the study. 15 patients were treated with Open reduction & internal fixation with volar placed buttress plate and 15 were treated with Closed r eduction & external fixation with „Jess fixator‟ and internal fixation with „k - wire‟ in volar displaced distal radial fractures. Patients were followed up at regular intervals and Anatomical and functional outcomes were evaluated in all the patients. RESUL TS: Patients treated with Open reduction & internal fixation, 8 showed excellent results, 5 good and 2 fair results. Patients treated with closed reduction and external fixation 4 showed excellent results, 5 good, 4 fair and 2 showed poor results. CONCLUSI ON: O.R.I.F is generally preferred modality gives better results in terms of functional recovery and decrease morbidity to patient

  15. Tranexamic acid reduces blood loss in patients with extracapsular fractures of the hip

    DEFF Research Database (Denmark)

    Tengberg, P T; Foss, N B; Palm, H

    2016-01-01

    AIMS: We chose unstable extra-capsular hip fractures as our study group because these types of fractures suffer the largest blood loss. We hypothesised that tranexamic acid (TXA) would reduce total blood loss (TBL) in extra-capsular fractures of the hip. PATIENTS AND METHODS: A single......-centre placebo-controlled double-blinded randomised clinical trial was performed to test the hypothesis on patients undergoing surgery for extra-capsular hip fractures. For reasons outside the control of the investigators, the trial was stopped before reaching the 120 included patients as planned in the protocol.......7) in the TXA group. The 90-day mortality was 27.2% (n = 9) in the TXA group and 10.2% (n = 4) in the placebo group (p = 0.07). We were not able to ascertain a reliable cause of death in these patients. DISCUSSION: TXA significantly reduced TBL in extra-capsular hip fractures, but concerns regarding its safety...

  16. Hip and fragility fracture prediction by 4-item clinical risk score and mobile heel BMD: a women cohort study

    Directory of Open Access Journals (Sweden)

    Thulesius Hans

    2010-03-01

    Full Text Available Abstract Background One in four Swedish women suffers a hip fracture yielding high morbidity and mortality. We wanted to revalidate a 4-item clinical risk score and evaluate a portable heel bone mineral density (BMD technique regarding hip and fragility fracture risk among elderly women. Methods In a population-based prospective cohort study we used clinical risk factors from a baseline questionnaire and heel BMD to predict a two-year hip and fragility fracture outcome for women, in a fracture preventive program. Calcaneal heel BMD was measured by portable dual X-ray laser absorptiometry (DXL and compared to hip BMD, measured with stationary dual X-ray absorptiometry (DXA technique. Results Seven women suffered hip fracture and 14 women fragility fracture/s (at hip, radius, humerus and pelvis among 285 women; 60% having heel BMD ≤ -2.5 SD. The 4-item FRAMO (Fracture and Mortality Index combined the clinical risk factors age ≥80 years, weight Conclusions In a follow-up study we identified high risk groups for hip and fragility fracture with our plain 4-item risk model. Increased fracture risk was also related to decreasing heel BMD in calcaneal bone, measured with a mobile DXL technique. A combination of high FRAMO Index, prior fragility fracture, and very low BMD restricted the high risk group to 11%, among whom most hip fractures occurred (71%. These practical screening methods could eventually reduce hip fracture incidence by concentrating preventive resources to high fracture risk women.

  17. Locked META intramedullary nailing fixation for tibial fractures via a suprapatellar approach

    OpenAIRE

    Beigang Fu

    2016-01-01

    Background: Intramedullary nailing is an effective approach for treatment of diaphyseal tibial fractures. However, infrapatellar intramedullary nailing can easily cause angulation and rotation displacement at the fracture ends and increase risk of postoperative infection. Intramedullary nailing via the suprapatellar approach was proved with good reduction and fixation. We used locked intramedullary nailing for the treatment of tibial fractures via a suprapatellar approach in this study. Mater...

  18. Arthroscopy-Assisted Reduction and Fixation of a Transversal Glenoid Fracture: About a Case

    Directory of Open Access Journals (Sweden)

    David Zbili

    2017-01-01

    Full Text Available An articular glenoid fracture is an uncommon injury. Usually significantly displaced intra-articular glenoid fractures are treated with open reduction surgery. Conventional open surgery techniques involve high morbidity. Here we describe an arthroscopy-assisted reduction and fixation method of an Ideberg type III glenoid fracture. This method provides good articular reduction without extensive exposure or soft tissue dissection and without nerve and/or vascular lesion.

  19. Displaced tibial shaft fractures treated with ASIF compression internal fixation

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Larsen, T K; Petersen, O C

    1990-01-01

    Fifty-one tibial shaft fractures treated by ASIF compression osteosynthesis were seen at follow-up at a median time of 46 weeks after injury. Twenty-four were open fractures and the patients received prophylactic antibiotics. The median stay in hospital was 15 days for open fractures and 6 days...... for closed fractures. There were complications in 26 cases, with deep infection in 9 cases. At present we cannot advocate the use of ASIF compression osteosynthesis for displaced tibial fractures....

  20. A comparison of bone density and bone morphology between patients presenting with hip fractures, spinal fractures or a combination of the two.

    Science.gov (United States)

    Crilly, Richard G; Cox, Lizebeth

    2013-02-22

    Currently it is uncertain how to define osteoporosis and who to treat after a hip fracture. There is little to support the universal treatment of all such patients but how to select those most in need of treatment is not clear. In this study we have compared cortical and trabecular bone status between patients with spinal fractures and those with hip fracture with or without spinal fracture with the aim to begin to identify, by a simple clinical method (spine x-ray), a group of hip fracture patients likely to be more responsive to treatment with current antiresorptive agents. Comparison of convenience samples of three groups of 50 patients, one with spinal fractures, one with a hip fracture, and one with both. Measurements consist of bone mineral density at the lumbar spine, at the four standard hip sites, number, distribution and severity of spinal fractures by the method of Genant, cortical bone thickness at the infero-medial femoral neck site, femoral neck and axis length and femoral neck width. Patients with spinal fractures alone have the most deficient bones at both trabecular and cortical sites: those with hip fracture and no spinal fractures the best at trabecular bone and most cortical bone sites: and those with both hip and spinal fractures intermediate in most measurements. Hip axis length and neck width did not differ between groups. The presence of the spinal fracture indicates poor trabecular bone status in hip fracture patients. Hip fracture patients without spinal fractures have a bone mass similar to the reference range for their age and gender. Poor trabecular bone in hip fracture patients may point to a category of patient more likely to benefit from therapy and may be indicated by the presence of spinal fractures.

  1. Application of a shape-memory alloy internal fixator for treatment of acetabular fractures with a follow-up of two to nine years in China.

    Science.gov (United States)

    Liu, Xinwei; Xu, Shuogui; Zhang, Chuncai; Su, Jiacan; Yu, Baoqing

    2010-10-01

    Displaced acetabular fractures should be treated surgically. Over the past decade, surgical approaches to the acetabulum and the surgical technique for repair of common fracture patterns have advanced. Excellent outcomes after repair of these injuries can be achieved. The aim of this study was to assess the medium-term results of reconstruction of acetabular fractures by using shape-memory alloy designed by the authors. This is a retrospective review conducted at a level 1 trauma centre. From October 1999 to July 2009, 19 patients with acetabular fractures were treated with our patented Ni-Ti shape-memory alloy acetabular tridimensional memory alloy-fixation system (ATMFS). The ATMFS device was cooled with ice before implantation and then warmed to 40-50°C after implantation to produce balanced axial and compression forces that would stabilise the fracture three dimensionally. Our results are as follows; according to the D'Aubigne-Postel scoring system: Fifteen cases out of 19 (79%) achieved excellent or good clinical results. In two patients, late complications included avascular necrosis of the femoral head (ANFH) associated with posterior dislocation of the hip joint two years after the operation. We also observed two cases of grade II or III ectopic ossification, with good hip function, and one case of traumatic arthritis. In conclusion, these results demonstrate the effectiveness of the ATMFS device for the management of acetabular fracture. The device provides continuous compression of the fracture with minimal disruption to the local blood supply.

  2. Application of a shape-memory alloy internal fixator for treatment of acetabular fractures with a follow-up of two to nine years in China

    Science.gov (United States)

    Liu, Xinwei; Xu, Shuogui; Su, Jiacan; Yu, Baoqing

    2009-01-01

    Displaced acetabular fractures should be treated surgically. Over the past decade, surgical approaches to the acetabulum and the surgical technique for repair of common fracture patterns have advanced. Excellent outcomes after repair of these injuries can be achieved. The aim of this study was to assess the medium-term results of reconstruction of acetabular fractures by using shape-memory alloy designed by the authors. This is a retrospective review conducted at a level 1 trauma centre. From October 1999 to July 2009, 19 patients with acetabular fractures were treated with our patented Ni-Ti shape-memory alloy acetabular tridimensional memory alloy-fixation system (ATMFS). The ATMFS device was cooled with ice before implantation and then warmed to 40–50°C after implantation to produce balanced axial and compression forces that would stabilise the fracture three dimensionally. Our results are as follows; according to the D’Aubigne−Postel scoring system: Fifteen cases out of 19 (79%) achieved excellent or good clinical results. In two patients, late complications included avascular necrosis of the femoral head (ANFH) associated with posterior dislocation of the hip joint two years after the operation. We also observed two cases of grade II or III ectopic ossification, with good hip function, and one case of traumatic arthritis. In conclusion, these results demonstrate the effectiveness of the ATMFS device for the management of acetabular fracture. The device provides continuous compression of the fracture with minimal disruption to the local blood supply. PMID:20012433

  3. Incidence and socioeconomic burden of hip fractures in Italy: extension study 2003-2005

    Directory of Open Access Journals (Sweden)

    G. Guglielmi

    2011-06-01

    Full Text Available Objectives: we aimed to analyze incidence and costs of hip fractures in Italy. Methods: we analyzed the Italian Ministry of Health national hospitalization and DRGs databases concerning fractures occurred in people ≥65 between 2003 and 2005. We have estimated incidence and direct costs sustained by the National Health Service for hospitalization and treatment of hip fractures on the basis of the value of the Diagnosis Related Groups (DRGs referring to hip fractures. The expenses of rehabilitation and indirect costs were based on regional estimations. Results: between 2003 and 2005 we registered almost 90,000 hospital admissions per year (corresponding to 75,000 patients because of hip fractures in people aged ≥65. Women accounted for the majority of hospital admissions due to hip fractures (78.0%; n=214,519. Among women, 84.3% of fractures (n=180,861 occurred in patients ≥75, which is known to be the age group with the highest prevalence of osteoporosis. Hospitalizations of both men and women showed an increasing trend across all the examined period. Hospital costs increased up to 467 million euros in 2005, while rehabilitation costs rose up to 531 million in the same year. Conclusions: hip fractures in the Italian population are increasing and represent a major public health challenge.

  4. Multidisciplinary osteoporosis management of post low-energy trauma hip-fracture patients.

    Science.gov (United States)

    Skorupski, Nicole; Alexander, Ivy M

    2013-01-01

    The purpose of this article is to increase awareness of osteoporosis incidence in patients with hip fracture among providers and allied health professionals, to increase osteoporosis recognition and treatment in post hip-fracture patients, and to provide guidance on how to improve continuity of care and collaboration between members of the multidisciplinary healthcare team. Recent evidence from the literature is reviewed to identify effective management strategies for post low-energy trauma hip-fracture patients and prevention of future osteoporotic fracture, regardless of osteoporosis diagnosis prior to the initial fracture. Despite the availability of accurate screening technologies and highly efficacious antiosteoporosis medications, implementation of these measures for low-energy trauma hip-fracture patients remains critically low. This is because of a number of factors including hesitancy to integrate care across specialty lines, lack of reliable referral systems, and resistance to change. There is also a lack of recognition of the connection between low-energy trauma hip fracture and osteoporosis by many healthcare professionals. All members of the multidisciplinary care team are called to action to adopt osteoporosis evaluation and treatment strategies that research has shown to be effective on a larger scale in the post hip-fracture setting. ©2012 The Author(s) Journal compilation ©2012 American Association of Nurse Practitioners.

  5. The role of sarcopenia in the risk of osteoporotic hip fracture.

    Science.gov (United States)

    Oliveira, A; Vaz, C

    2015-10-01

    Several common age-related mechanisms and factors influence muscle and bone, affecting functionality of both tissues. Sarcopenia is closely linked with osteoporosis, and their combined effect may exacerbate negative health outcomes. Fall-related fractures are some of the most serious consequences of these two systemic pathologies, with hip fracture being a major complication affecting osteoporotic and sarcopenic elderly. This work aims to review the literature on the current state of knowledge about the relations between sarcopenia and osteoporosis and to present the association between sarcopenia and osteoporosis and the risk of hip fracture. A literature search was performed in PubMed and Scopus databases for articles with the predefined terms "sarcopenia," "muscular atrophy," "femoral fractures," "hip fractures," "osteoporosis," and "bone density." There is a growing and significant interest being directed to sarcopenia and associated risk for osteoporotic hip fracture, but there still is a notorious heterogeneity in the methodology and cohort size of the available studies. Collectively, most of the studies herein analyzed indicate that sarcopenia could be a predictor of risk for hip fracture. The simultaneous evaluation of sarcopenia and osteoporosis may be of importance in identifying those patients in higher risk of suffering an osteoporotic hip fracture and who could benefit from preventive or therapeutic interventions, or both.

  6. Subgroup variations in bone mineral density response to zoledronic acid after hip fracture.

    Science.gov (United States)

    Magaziner, Jay S; Orwig, Denise L; Lyles, Kenneth W; Nordsletten, Lars; Boonen, Steven; Adachi, Jonathan D; Recknor, Chris; Colón-Emeric, Cathleen S; Mesenbrink, Peter; Bucci-Rechtweg, Christina; Su, Guoqin; Johnson, Rasheeda; Pieper, Carl F

    2014-12-01

    Minimizing post-fracture bone loss is an important aspect of recovery from hip fracture, and determination of factors that affect bone mineral density (BMD) response to treatment after hip fracture may assist in the development of targeted therapeutic interventions. A post hoc analysis of the HORIZON Recurrent Fracture Trial was done to determine the effect of zoledronic acid (ZOL) on total hip (TH) and femoral neck (FN) BMD in subgroups with low-trauma hip fracture. A total of 2127 patients were randomized (1:1) to yearly infusions of ZOL 5 mg (n = 1065) or placebo (n = 1062) within 90 days of operation for low-trauma hip fracture. The 1486 patients with a baseline and at least one post-baseline BMD assessment at TH or FN (ZOL = 745, placebo = 741) were included in the analyses. Percentage change from baseline in TH and FN BMD was assessed at months 12 and 24 and compared across subgroups of hip fracture patients. Percentage change from baseline in TH and FN BMD at months 12 and 24 was greater (p 6 weeks post-surgery; and for TH and FN BMD in patients with a history of one or more prior fractures. All interactions were limited to the first 12 months after treatment with none observed for the 24-month comparisons. (Clinical trial registration number NCT00046254.) © 2014 American Society for Bone and Mineral Research.

  7. Short segmental pedicle screw fixation combined with percutaneous vertebroplasty in treatment of nonadjacent thoracolumbar fractures

    Institute of Scientific and Technical Information of China (English)

    HE Qing-yi; XU Jian-zhong

    2009-01-01

    To evaluate the short-term outcomes of short segmental pedicle screw fixation combined with per-cutaneous vertebroplasty in treatment of nonadjacent tho-racolumbar fractures. Methods: Twenty patients who suffered from nonadja-cent thoracolumbar fractures were treated by short segmental pedicle screw fixation for burst fracture and by percutane-ous vertebroplasty for compression fracture. X-rays, CT and MRI scans were conducted using the same protocol before and after surgery and during follow-up. Pre- and post-operative American Spinal Injury Association (ASIA) grades, fusion of fracture sites, visual analog scale (VAS) of back pain, and Oswestry disability index (ODI) were accessed. Results: All patients were followed up for an average period of 12 months. The sagittal profile of the thoracolum-bar spine was restored satisfactorily. No patient had neuro-logic deterioration after surgery, and 9 patients with incom-plete lesions improved postoperatively by at least one ASIA grade. The fusion rate was 100%. The average VAS of back pain was 7.6 preoperatively and 3.2 postoperatively. The average ODI was 72.5 preoperatively and 35.5 postoperatively. Conclusions: Short segmental pedicle screw fixation combined with percutaneous vertebroplasty in treatment of nonadjacent thoracolumbar fractures exhibits such advan-tages as preserving functional segment units, reliable fixation, good neurologic recovery and early mobilization and, therefore, is suitable for treating nonadjacent thora-columbar fractures.

  8. Primary hip spica with crossed retrograde intramedullary rush pins for the management of diaphyseal femur fractures in children: A prospective, randomized study

    Directory of Open Access Journals (Sweden)

    Mohammad Ruhullah

    2014-01-01

    Full Text Available Background: Femoral fractures are common in children aged between 2 and 12 yearsand 75% of the lesions affect the femoral shaft. Traction followed by a plaster cast is universally accepted as a conservative treatment. We compared primary hip spica or traction followed by hip spica with closed reduction and fixation with retrogradely passed crossed Rush pins for diaphyseal femur fracture in 25 children of the age group 3-12 years, randomly distributed in each group. Materials and Methods: Fifty children (age: 3-13 years, mean; 9 years with femoral fractures were evaluated; 25 of them underwent the conservative treatment using immediate hip spica (group A and 25 underwent treatment with crossed retrograde Rush pins (group B. Results: Mean duration of fracture union was within 15 weeks in group A and 12 weeks in group B. Mean duration of weight bearing was 14weeks in group A and 7 weeks in group A. Mean hospital stay were 4 days in group A and 8days in group B. The man follow-up period was 16 months in group A and 17 months in group B. Complications like angulation, shortening and infection were compared. Bursitis and penetration of pins at the site of Rush pin insertion is a complication associated with this method of treatment. Conclusion: Closed reduction and internal fixation with crossed Rush pins was a superior treatment method in terms of early weight bearing and restoration of normal anatomy.

  9. Postoperative Treatment of Pain after Hip Fracture in Elderly Patients with Dementia

    DEFF Research Database (Denmark)

    Jensen-Dahm, Christina; Palm, Henrik; Gasse, Christiane

    2016-01-01

    BACKGROUND/AIMS: Prior studies have shown that patients with dementia are at risk of receiving insufficient treatment for pain after a hip fracture. We therefore hypothesized that elderly hip fracture patients with dementia received less postoperative pain treatment than those without dementia....... METHOD: All patients (age ≥65 years) who had been operated on for a hip fracture in the Copenhagen University Hospital region in 2009 were included. Data about analgesic use for the first 72 h after surgery were acquired from the hospitals' electronic medication system and linked with information about...

  10. Arthroscopic double-row suture anchor fixation of minimally displaced greater tuberosity fractures.

    Science.gov (United States)

    Ji, Jong-Hun; Kim, Weon-Yoo; Ra, Ki-Hang

    2007-10-01

    In cases of displaced greater tuberosity fractures, treatments by arthroscopic-assisted reduction and percutaneous screw fixation have been reported. However, in cases in which there is a comminuted fracture or a minimally displaced fracture combined with concomitant lesions such as rotator cuff tear or labral pathology, it is difficult to reduce the fracture and to treat other pathologies by use of a percutaneous screw. Recently, many surgeons have used the double-row repair method in rotator cuff repair, which provides a tendon-bone interface better suited for biologic healing and restoring normal anatomy. In accordance with this method, we used the arthroscopic technique of double-row suture anchor fixation for a minimally displaced greater tuberosity fracture without additional incision. Initially, debridement was performed on the fracture surface by use of a shaver, and the medial-row anchor was inserted through the anterior portal or the intact cuff. Two lateral-row anchors were inserted just anterior and posterior to the lower margin of the fractured fragment under C-arm guidance. The medial-row sutures and lateral-row sutures were then placed. Arthroscopic double-row suture anchor fixation of a displaced greater tuberosity fracture restores the original footprint of the rotator cuff and normal tendon-bone interface of the displaced greater tuberosity fracture.

  11. INTRA MEDULLARY FIXATION OF SUB TROCHANTERIC FRACTURERS WITH LONG PROXIMAL FEMORAL NAIL & STAINLESS STEEL WIRE FIXATION: A STUDY

    Directory of Open Access Journals (Sweden)

    Sree Krishna

    2015-01-01

    Full Text Available INTRODUCTION: The objective of this study was to prospectively evaluate the clinical outcome of traumatic subtrochanteric fractures fixed with long proximal femoral nail (PFN & Stainless s te e l wire banding Fixation with particular emphasis on our experience of surgical techniques. Materials and Methods: We reviewed the results of 49 consecutive patients who had undergone intramedullary fixation specifically with a long PFN with S.S wire banding fixation for traumatic subtrochanteric fractures in our hospital during a 2 - year period from January 2013 to December 2014. The average age of the patients was 53 years. Clinical and radiographic analyses were performed when follow - up was made at 6 weeks, 12 weeks, 6 months, 1 year and 2 years. Results: All the 49 traumatic subtro chanteric fractures healed uneventfully except 1 case of delayed union. Walking and squatting ability was completely restored in every case at follow - up examination 6 months postoperatively. Among them, 32 fractures were successfully reduced with traction on a fracture table under fluoroscopy & cerclage wiring or bandage with S.S wire of various diameters (1.6, 1.8 etcthrough a small incision near the fragment to be fixed. The average operative time was 70 minutes (range, 45 to 120. Seventeen Seinsheimer type II fractures were left unlocked distally, and static distal interlocking with 1 bolt was carried out in the other 31 cases. No complications such as cutout or breakage of the implants were encountered. Conclusions: The objective of this study was to evaluate the clinical and radiological outcome of traumatic subtrochanteric fractures with trochanteric exten sion treated with long proximal femoral locking nail (PFNL & S.S wire. This study suggests that long PFN is a reliable implant for subtrochanteric fractures, leading to high rate of bone union and minimal soft tissue damage. Intramedullary fixation has bi ological and biomechanical advantages, but the operation

  12. Intramedullary versus extramedullary fixation in the management of subtrochanteric femur fractures: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Liu PC

    2015-04-01

    Full Text Available Pengcheng Liu,1,2,* Xing Wu,1,* Hui Shi,1,2 Run Liu,1 Hexi Shu,1 JinPeng Gong,1 Yong Yang,1 Qi Sun,1 Jiezhou Wu,1,2 Xiaoyang Nie,1 Ming Cai1 1Department of Orthopedics, Shanghai Tenth People’s Hospital, Tongji University, School of Medicine, Shanghai, 2First Clinical Medical College, Nanjing Medical University, Nanjing, People’s Republic of China *These authors contributed equally to this work Background: Intramedullary and extramedullary fixation methods are used in the management of subtrochanteric femur fractures. However, whether intramedullary or extramedullary fixation is the primary treatment for subtrochanteric femur fractures in adults remains debatable.Level of evidence: Meta-analyses of prospective studies, level I.Materials and methods: The Cochrane library, Embase, Google Scholar, and PubMed databases were searched separately for all relevant studies published before January 1, 2015. No language restriction was applied. Prospective randomized controlled trials that compared intramedullary or extramedullary internal fixation to repair subtrochanteric femur fractures in adults were included. We determined intraoperative data, postoperative complications, fracture fixation complications, wound infection, hospital stay days, and final outcome measures to assess the relative effects of different internal fixation methods for the treatment of subtrochanteric femur fractures in adults.Results: Six studies were included in our meta-analysis. The relative risks (RRs of revision rate was 83% lower (RR, 0.17, 95% confidence interval [CI], 0.05 to 0.60; P=0.006, fixation failure rate was 64% lower (RR, 0.36, 95% CI, 0.12 to 1.08; P=0.07, non-union rate was 77% lower (RR, 0.23, 95% CI, 0.07 to 0.81; P=0.02 in the intramedullary group compared with the extramedullary group. No significant differences were found between the intramedullary group and extramedullary group for intraoperative data, postoperative complications, wound infection

  13. Cortical thickness mapping to identify focal osteoporosis in patients with hip fracture.

    Directory of Open Access Journals (Sweden)

    Kenneth E S Poole

    Full Text Available BACKGROUND: Individuals with osteoporosis are predisposed to hip fracture during trips, stumbles or falls, but half of all hip fractures occur in those without generalised osteoporosis. By analysing ordinary clinical CT scans using a novel cortical thickness mapping technique, we discovered patches of markedly thinner bone at fracture-prone regions in the femurs of women with acute hip fracture compared with controls. METHODS: We analysed CT scans from 75 female volunteers with acute fracture and 75 age- and sex-matched controls. We classified the fracture location as femoral neck or trochanteric before creating bone thickness maps of the outer 'cortical' shell of the intact contra-lateral hip. After registration of each bone to an average femur shape and statistical parametric mapping, we were able to visualise and quantify statistically significant foci of thinner cortical bone associated with each fracture type, assuming good symmetry of bone structure between the intact and fractured hip. The technique allowed us to pinpoint systematic differences and display the results on a 3D average femur shape model. FINDINGS: The cortex was generally thinner in femoral neck fracture cases than controls. More striking were several discrete patches of statistically significant thinner bone of up to 30%, which coincided with common sites of fracture initiation (femoral neck or trochanteric. INTERPRETATION: Femoral neck fracture patients had a thumbnail-sized patch of focal osteoporosis at the upper head-neck junction. This region coincided with a weak part of the femur, prone to both spontaneous 'tensile' fractures of the femoral neck, and as a site of crack initiation when falling sideways. Current hip fracture prevention strategies are based on case finding: they involve clinical risk factor estimation to determine the need for single-plane bone density measurement within a standard region of interest (ROI of the femoral neck. The precise sites of focal

  14. Surgical treatment of zygomatic bone fracture using two points fixation versus three point fixation-a randomised prospective clinical trial

    OpenAIRE

    2012-01-01

    Abstract Background The zygoma plays an important role in the facial contour for both cosmetic and functional reasons; therefore zygomatic bone injuries should be properly diagnosed and adequately treated. Comparison of various surgical approaches and their complications can only be done objectively using outcome measurements which in turn require protocol management and long-term follow up. The preference for open reduction and internal fixation of zygomatic fractures at three points has con...

  15. Comparison of Internal Fixations for Distal Clavicular Fractures Based on Loading Tests and Finite Element Analyses

    Directory of Open Access Journals (Sweden)

    Rina Sakai

    2014-01-01

    Full Text Available It is difficult to apply strong and stable internal fixation to a fracture of the distal end of the clavicle because it is unstable, the distal clavicle fragment is small, and the fractured region is near the acromioclavicular joint. In this study, to identify a superior internal fixation method for unstable distal clavicular fracture, we compared three types of internal fixation (tension band wiring, scorpion, and LCP clavicle hook plate. Firstly, loading tests were performed, in which fixations were evaluated using bending stiffness and torsional stiffness as indices, followed by finite element analysis to evaluate fixability using the stress and strain as indices. The bending and torsional stiffness were significantly higher in the artificial clavicles fixed with the two types of plate than in that fixed by tension band wiring (P<0.05. No marked stress concentration on the clavicle was noted in the scorpion because the arm plate did not interfere with the acromioclavicular joint, suggesting that favorable shoulder joint function can be achieved. The stability of fixation with the LCP clavicle hook plate and the scorpion was similar, and plate fixations were stronger than fixation by tension band wiring.

  16. [Hip Fracture--Epidemiology, Management and Liaison Service. Prevention of the secondary hip fractures utilizing the regional post-referral treatment plan].

    Science.gov (United States)

    Matsushita, Mutsumi

    2015-04-01

    Fragility fracture can result in a series of fractures, with the need for the prevention of secondary hip fractures seen as increasingly pertinent in Japan. In 2006, regional post-referral treatment plans for femoral neck fracture came into effect in Japan, but treatment of fracture and prevention of secondary fracture were fragmented. Patient education about prevention included on explanation forms were commenced, but the levels of discharge prescription for osteoporosis medications did not indicate an improvement. We evaluated a fracture liaison service for post-referral treatment plans for femoral neck fracture, by registering rehabilitation-stage hospitals and surveying data over a six-month period about whether there was prescription of osteoporosis medications on discharge, and the varieties of medication prescribed.

  17. Comparison of outcomes following uncemented hemiarthroplasty and dynamic hip screw in the treatment of displaced subcapital hip fractures in patients aged greater than 70 years.

    LENUS (Irish Health Repository)

    El-Abed, Kaldoun

    2012-02-03

    As health care costs increase, evaluating treatment methods in femoral neck fractures to determine the most effective treatment paradigm will become increasingly important. The current study compared two methods of treatment in similar cohorts of displaced femoral neck fractures. One hundred and twenty two patients were randomly assigned to two groups: In Group A, 62 patients were treated with a hemiarthroplasty. In group B, 60 patients were treated with dynamic screw fixation. Patients were evaluated at a minimum 3 year follow-up. Using the Matta functional hip score, 42% of group A and 70% of group B had good to excellent results. This difference was significant (p = 0.004). A significant agreement between physician assessment using the Matta score, and patient perception of outcome using the SF-36 scale was demonstrated (r = 0.64). No statistical difference between groups for revision surgery existed. Both physician based and patient based outcome scores favour retention and internal fixation of the femoral head in this cohort of patients at a short-term follow-up.

  18. Association of the presence of bone bars on radiographs and hip fracture in postmenopausal Caucasian women.

    Science.gov (United States)

    Sarver, D B; Lopez-Ben, R; Morgan, S L; Rehder, D; Duke, J N; Fineberg, N; Pitt, M J

    2012-09-01

    To determine whether the presence of bone bars (BB) identified on anteroposterior hip radiographs are more prevalent in patients that have had a hip fracture as compared to patients without a fracture. Ninety-two Caucasian women with a unilateral proximal femur fracture were retrospectively evaluated and randomly selected using radiology database records to comprise the investigational group. Ninety-eight age-matched Caucasian women without hip fracture were selected as a control group. Anteroposterior hip radiographs were evaluated for the presence of BBs by two musculoskeletal radiologists. Chi-square tests were used to assess whether fractures were more prevalent in patients with BB than those without BB. The patient population was comprised Caucasian women with a mean age of 79.8 ± 6.4 years in the control group and 79.9 ± 6.6 years in the investigational group. Regardless of the reader, BB were identified in a significantly higher percentage of women with a fracture (75 versus 39%, p fracture. BB are associated with hip fracture. Their presence is a trigger for requesting a dual-energy x-ray absorptiometry (DXA) examination to confirm or refute a diagnosis of low bone mineral density (BMD) and a subsequent increased risk of fracture. Copyright © 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  19. A unique peri-prosthetic fracture pattern in well fixed femoral stems with polished, tapered, collarless design of total hip replacement.

    Science.gov (United States)

    Grammatopoulos, George; Pandit, Hemant; Kambouroglou, Gregoris; Deakin, Mark; Gundle, Roger; McLardy-Smith, Peter; Taylor, Adrian; Murray, David

    2011-11-01

    Peri-prosthetic fractures (PPF) are a recognised complication following hip arthroplasty. Prosthesis design and type influence PPF pattern. Surgeons rely on classification systems, such as the Vancouver, to aid treatment planning. This study highlights a specific fracture pattern that occurs with cemented well-fixed polished, tapered, collarless (PTC) stems. We reviewed a consecutive series of 21 PPF around well fixed PTC stems. The majority of the fractures were classified pre-operatively as Vancouver B2 (14/21), but there were also B1 (6/21) and A type fractures. The B2 fractures had common radiological and intra-operative findings: a spiral fracture with extensive fragmentation of bone and cement, debonding of cement from the implant, cement fracture, and a well-fixed cement-bone interface. Reconstruction of these fractures was more difficult than suggested by the radiographs. Two of the six patients who were considered to have a Vancouver B1 fracture underwent open reduction and internal fixation (ORIF), and had treatment-related complications. Retrospective review of the radiographs showed subtle features, such as subsidence of the stem into the centraliser, that are characteristic of a B2 fracture pattern. In summary, it is important to recognise this fracture pattern around secure PTC stems in order to prevent misinterpretation of the fracture as a Vancouver B1 rather than a B2, leading to failure of treatment, and to alert the surgeon that complex reconstruction will be required because of the extensive fragmentation.

  20. Effect of dynamic hip system blade on the treatment of femoral neck fractures in elderly patients with osteoporosis

    Institute of Scientific and Technical Information of China (English)

    Zhao Wenbo; Liu Lei

    2014-01-01

    Objective:To discuss the curative effect of the dynamic hip system blade (DHS-blade) on the treatment of femoral neck fractures in elderly patients with osteoporosis.Methods:A retrospective study was conducted to analyse the clinical data of 60 elderly patients with osteoporosis who had been treated for femoral neck fractures with DHS-blade in our department between September 2012 and February 2014.There were 22 males and 38 females with a mean age of (66.8±3.2) years.According to the Singh Index Classification,all the patients' Singh index was below level 3.The Harris criterion and function recovery after operation were analysed.Results:All patients were followed up for 12-17 months (mean 14 months).No femoral head necrosis,femoral neck shortening,internal fixation loosening or backing out of the nails occurred.Bone nonunion was found in one case and he had a good recovery after total hip arthroplasty.The time for fracture healing ranged from 3-6 months (average 3.5 months).According to Harris criterion,35 cases were rated as excellent,22 good,2 fair and 1 poor.The Harris scale was significantly improved from 28.46±2.35 preoperatively to 91.98±3.26 at 6 months postoperatively (P<0.05).Conclusion:DHS-blade,being minimally invasive,allowing earlier postoperative exercise and avoiding the complications elicited by traditional internal fixation,is advisable for treatment of femoral neck fractured patients with osteoporosis.

  1. Intraocular pressure variations during zygomatic fracture reduction and fixation: a clinical study.

    LENUS (Irish Health Repository)

    Murray, Dylan J

    2012-02-03

    BACKGROUND: The reduction of midface fractures has been associated with the rare but devastating complication of blindness. An increase in intraocular pressure is important in the mechanism of blindness in this setting. In this study, the authors assessed the intraocular pressure in patients who underwent zygomatic fracture reduction (with or without fixation). METHODS: Using applanation tonometry, 29 patients underwent intraocular pressure measurements before, during, and after fracture fixation. The contralateral pressures were measured and used as the control. RESULTS: There were 29 patients with a mean age of 35 years, and the mean time to surgery was 5 days. Preoperatively, all patients had normal intraocular pressures and normal visual acuity. All patients underwent a Gillies lift and 18 patients required open reduction and fixation of the frontozygomatic suture (n = 4) or the infraorbital margin (n = 2), and the remainder (n = 12) required fixation of both points. There was no statistically significant increase in the intraocular pressures following the reduction of uncomplicated zygomatic fractures. Statistically significant pressure reductions were noted immediately after reduction and fixation. CONCLUSIONS: The surgical reduction of uncomplicated zygomatic fractures has no adverse effect on the intraocular pressure. It is the authors\\' opinion that adjunctive measures to reduce the pressures are unnecessary.

  2. Finite element analysis of the stability of combined plate internal fixation in posterior wall fractures of acetabulum.

    Science.gov (United States)

    Liu, Xi-Ming; Pan, Chang-Wu; Wang, Guo-Dong; Cai, Xian-Hua; Chen, Lei; Meng, Cheng-Fei; Huang, Jin-Cheng

    2015-01-01

    This study aims to explore the mechanical stability of combined plate internal fixation in posterior wall fractures of the acetabulum. The fracture and internal fixation models were established in this study and they were divided into four kinds of internal fixation models, finite element analysis was performed. The four groups were 2 mini-plates and 1 reconstruction plate fixation (A), Reconstruction plate internal fixation group (B), 2 screws internal fixation group (C) and mini-plates internal fixation group (D). The displacement of each node was measured and evaluated. There was no distortion in the geometric shape of the finite element model. The results of stress showed that it was less in the anterior pelvic ring and distributed uniform in labrum acetabulare; the stress was bigger in the upper and middle of sacroiliac joint and sciatic notch in sitting position. Combined plate internal fixation for posterior wall fractures of acetabular were stable and reliable, it is better than the other three methods.

  3. A vast increase in the use of CT scans for investigating occult hip fractures

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, Robert, E-mail: Robert.jordan@doctors.org.uk; Dickenson, Edward, E-mail: edwarddickenson@doctors.org.uk; Westacott, Daniel, E-mail: dan_westacott@hotmail.com; Baraza, Njalalle, E-mail: njaleb@Doctors.Org.Uk; Srinivasan, Kuntrapka, E-mail: bijusri@Yahoo.Co.Uk

    2013-08-15

    Background: Early diagnosis in neck of femur fractures has been shown to improve outcome. The National Institute for Clinical Excellence recommends if an occult hip fracture is suspected then an MRI should be performed and if not available within 24 h a CT should be considered. At our centre, emergency MRI is rarely available and so CT is commonly used. Objectives: Our study aims to analyse the trends in CT use over a five year period for the diagnosis of neck of femur fractures. Methods: Both the number of patients with a hip fracture and those undergoing a CT hip to diagnose an occult injury were identified across two district general hospitals between 2006–2007 and 2010–2011. The time from initial radiograph to CT and initial radiograph to operation were calculated. Results: In 2006–2007, of 547 hip fractures, 20 CT hips were performed and 6 reported as a fractured neck of femur (30%). In 2010–2011, of 499 hip fractures, 239 CT hips were performed and 65 fractures were recognised (27%). The mean time from radiograph until CT scan was 2.0 days in 2007 and 3.2 days in 2011, which was a statistically significant difference (p < 0.001). For those diagnosed using a CT scan the mean time from admission X-ray to surgery was 1.2 days in 2007 and 3.6 days in 2011. Conclusion: Clinicians are becoming increasingly reliant on CT for the diagnosis of hip fractures with our data suggesting further imaging is one factor that can delay time to diagnosis and theatre.

  4. Evaluation results of using sole Ilizarov fixator in Pilon fractures

    Directory of Open Access Journals (Sweden)

    Ahmad Reza Mirbolook

    2014-02-01

    Conclusion: According to the results obtained and comparing them with the results of other treatments ,one can claim that this treating approach is better than the others for pilon fractures,particularly for type 3c pilon fractures.

  5. Treatment of Pediatric Open Femoral Fractures with External Fixator Versus Flexible Intramedullary Nails

    Directory of Open Access Journals (Sweden)

    Hossein Aslani

    2013-12-01

    Full Text Available   Background: In children, inappropriate treatment of open femoral fractures may induce several complications. A few studies have compared the external fixator with flexible intramedullary nails in high-grade open femoral fractures of children. The present study aims at comparing results of these two treatment methods in open femoral fractures. Methods: In this descriptive analytical study, 27 patients with open femoral fractures, who were treated using either the external fixator (n=14 or TEN nails (n=13 method from 2006-2011, were studied. Some patients were treated with a combination method of TEN and pin. The results were evaluated considering infection, union, malunion, and refracture and the patients were followed up for two years. Results: Mean time required for fracture union was 3.89 (range: 2-5.8 and 3.61 (range: 2-5.6 months for the external fixator and TEN groups, respectively. The difference was not statistically significant and there was not any significant difference between the two groups considering infection of the fractured area. Osteomyelitis was not observed in any group. There was an infection surrounding the external fixator pin in 4 cases (28.5% and so this required changing the location of the pin. In the TEN group, one case (7.6% of painful bursitis was observed at the entry point of TEN and so the pin was removed earlier than usual. There were two cases (14.2% of femoral refracture in the external fixator group. Malunion requiring correction was not observed in any of the groups. There were no complications observed in five patients treated with a combined method of pin and flexible intramedullary nails. Conclusion: Both external fixator and intramedullary nail methods are effective ways in treating high grade open femoral fractures in children and final treatment results are similar. Combining pins and flexible intramedullary nails is effective in developing more stability and is not associated with more

  6. Femoral Geometry in Male Patients with Atraumatic Hip Fracture - Original Investigation

    Directory of Open Access Journals (Sweden)

    Gülten Tan

    2007-03-01

    Full Text Available Aims: Hip fracture is the most serious complication of osteoporosis and the most disabling type of fracture. In this study, we aimed to compare femoral geometry in hip fractured male patients aged more than 65 years old with age matched controls. Patients and Methods: 20 male patients with a history of nontraumatic hip fracture and 19 age-matched healthy controls were included in this study. Bone mineral density of neck and trochanter of hip were measured by DEXA. In addition to BMD, an experienced radiologist measured proximal femur geometric parameters potentially involved in bone strength. Results: Mean BMDs of trochanteric region were not significantly different between groups, but mean BMDs of neck region were statistically significantly lower in the hip fractured group. Neck shaft angle and femur shaft width were the geometric parameters found to be significantly higher in the hip fractured group. The correlation between femur geometric and the anthropometric measurements was present only in the kontrol group. Conclusion: We concluded that besides femur geometric measurements, correlation between these measurements might be an important factors for the fracture risk. (From the World of Osteoporosis 2007;13:15-8

  7. External fixation to correct tarsal-metatarsal fracture in rock pigeon (Columba livia

    Directory of Open Access Journals (Sweden)

    Leandro Almeida Rui

    Full Text Available ABSTRACT Orthopedic conditions, such as bone fractures, are very common in avian medicine. External fixators have been considered the gold standard for birds, since they allow early movement of the limbs and minimal invasive surgery. Fractures in several bones have been successfully treated in pigeons. However, to the best of our knowledge, this case represents the first report of successful surgical repair of tarsal-metatarsal fracture in rock pigeon. External fixator was made with four 24G catheters, being inserted manually proximal and distal to the fracture and connected with polymerizable acrylic. Radiographic consolidation of fracture was observed 60 days post-surgery and anti-inflammatory and antibiotic protocols were successful on avoiding pain and infection during surgery and bone healing.

  8. Removal of internal fixation--the effect on patients' complaints: a study of 66 cases of removal of internal fixation after malleolar fractures

    DEFF Research Database (Denmark)

    Jacobsen, S; Honnens de Lichtenberg, M; Jensen, C M

    1994-01-01

    To estimate the effect of removal of internal fixation after treatment of malleolar fractures on postoperatively presented complaints, we retrospectively evaluated 66 patients by their records and by personal questionnaires. Of all the patients, 89.4% had one or more complaints. These were typica...... period. We conclude that removal of internal fixation after malleolar fractures is indicated when common types of complaints are presented.......To estimate the effect of removal of internal fixation after treatment of malleolar fractures on postoperatively presented complaints, we retrospectively evaluated 66 patients by their records and by personal questionnaires. Of all the patients, 89.4% had one or more complaints. These were...

  9. Treatment of a Fracture-dislocation of the Ankle Using RALCA® External Fixator

    Directory of Open Access Journals (Sweden)

    Yaniel Truffin Rodriguez

    2016-06-01

    Full Text Available The association of ankle fractures with a dislocation modifies their therapeutic management since the joint must not remain in such abnormal position for more than six hours and therefore, urgent surgical treatment is needed. The case of a 30-year-old woman treated at the Dr. Gustavo Aldereguía Lima Hospital in Cienfuegos is presented. The patient presented with a severe fracture-dislocation of the right ankle with a supra-syndesmotic fibular fracture, a syndesmotic injury, a deltoid ligament injury and a tibial plafond fracture resulting from a bicycle fall. The fracture-dislocation was stabilized by using a RALCA® external mini-fixator. Full recovery was achieved five months after surgery. In our service, we may not have the devices most commonly used for fixation of ankle injuries at a given moment; therefore, external fixation becomes a viable option to correct this type of fractures. For this reason, we decided to present this case that demonstrates the effectiveness of the RALCA® external fixator.

  10. Does achieving the best practice tariff improve outcomes in hip fracture patients? An observational cohort study

    National Research Council Canada - National Science Library

    Oakley, B; Nightingale, J; Moran, CG; Moppett, IK

    2017-01-01

      Objectives To determine if the introduction of the best practice tariff (BPT) has improved survival of the elderly hip fracture population, or if achieving BPT results in improved survival for an individual...

  11. Comparing prophylactic effect of phenylephrine and ephedrine on hypotension during spinal anesthesia for hip fracture surgery

    Directory of Open Access Journals (Sweden)

    Rahman Abbasivash

    2016-01-01

    Conclusion: At the doses of ephedrine and phenylephrine administered in this trial, phenylephrine was better to prevent hypotension during hip fracture surgery with spinal anesthesia. Higher frequency of hypotension was observed in the ephedrine group.

  12. Prospective comparison of the anterior and lateral approach in hemiarthroplasty for hip fractures: a study protocol

    National Research Council Canada - National Science Library

    Max P L van der Sijp; Inger B Schipper; Stefan B Keizer; Pieta Krijnen; Arthur HP Niggebrugge

    2017-01-01

    .... The aim of this study is to compare postoperative complications, hip function and patient mobility after hemiarthroplasty via the anterior or lateral approach following a displaced femoral neck fracture...