WorldWideScience

Sample records for hip arthroplasty patients

  1. Total hip arthroplasty in heart transplant patients.

    Science.gov (United States)

    León, José Luis; Resines, Carlos; Zafra, Alberto

    2007-12-01

    Avascular necrosis of the femoral head (AVNFH) is a known complication after heart transplantation. In order to assess the efficacy and complications of cementless total hip arthroplasty (THA) in this population, the authors analysed 24 cementless THAs in 18 patients with advanced AVNFH (stage II affecting more than 15% of the articular surface, stage III and IV according to the Ficat-Arlet classification) after a heart transplant procedure. Average duration of follow-up was 35.4 months (range: 16 to 66). Pain and function scores (Harris Hip Score and WOMAC arthritis index) showed significant improvement from the preoperative levels. There was no evidence of component loosening, heart-related complications or infection following the THA. Cementless THA is a reasonable treatment option for advanced avascular necrosis of the femoral head following heart transplant procedures.

  2. Hip resurfacing arthroplasty

    OpenAIRE

    2010-01-01

    Background and purpose Hip resurfacing arthroplasty is claimed to allow higher activity levels and to give better quality of life than total hip arthroplasty. In this literature review, we assessed the therapeutic value of hip resurfacing arthroplasty as measured by functional outcome. Methods An extensive literature search was performed using the PubMed, Embase, and Cochrane databases. Results 9 patient series, 1 case-control study, and 1 randomized controlled trial (RCT) were included. Clin...

  3. Preoperative Patient Education for Hip and Knee Arthroplasty: Financial Benefit?

    Science.gov (United States)

    Tait, Mark A; Dredge, Carter; Barnes, C Lowry

    2015-01-01

    Of 904 patients who underwent primary total knee arthroplasty (TKA) and total hip arthroplasty (THA) at the same hospital, 802 participated in a preoperative education day called "Joint Academy" (JA). The length of stay of JA participants was 2.12 days (49.5%) less than patients who did not attend a JA (p education program may significantly reduce overall costs for primary TKA and THA procedures.

  4. Hip arthroplasty in obese patients: rising prevalence – standard procedures?

    Directory of Open Access Journals (Sweden)

    Michael Skutek

    2016-06-01

    Full Text Available We examined our experience and, in particular, complications associated with total hip arthroplasty in obese and morbidly obese patients. We prospectively gathered 50 patients in a matched control series including 25 obese and morbidly obese patients. All patients were operated using the direct lateral approach and standard postoperative protocols. Operating room time, complications, dislocations, blood loss, cup position and clinical parameters using the Harris Hip Score and the Western Ontario and McMaster Universities Arthritis Index results were compared. Although there were some significant differences in clinical outcomes, standard procedures yielded good overall results and an acceptable rate of complications. Details approaching this patient entity are being discussed.

  5. Pre-operative ambulatory measurement of asymmetric leg loading during sit to stand in hip arthroplasty patients

    NARCIS (Netherlands)

    Martínez-Ramírez, Alicia; Weenk, Dirk; Lecumberri, Pablo; Verdonschot, Nico; Pakvis, Dean; Veltink, Peter H.

    2013-01-01

    Total hip arthroplasty is a successful surgical procedure to treat patients with hip osteoarthritis. Clinicians use different questionnaires to evaluate these patients. Gait velocity and these questionnaires; usually show significant improvement after total hip arthroplasty. This clinical evaluation

  6. Preoperative ambulatory measurement of asymmetric leg loading during sit-to-stand in hip arthroplasty patients

    NARCIS (Netherlands)

    Martinez-Ramirez, A.; Weenk, D.; Lecumberri, P.; Verdonschot, N.J.; Pakvis, D.; Veltink, P.H.

    2014-01-01

    Total hip arthroplasty (TGA) is a successful surgical procedure to treat patients with hip osteoarthritis. Clinicians use different questionnaires to evaluate these patients. Gait velocity and these questionnaires; usually show significant improvement after TGA . This clinical evaluation does, howev

  7. Total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Slavković Nemanja

    2012-01-01

    Full Text Available Total hip arthroplasty is most common reconstructive hip procedure in adults. In this surgery we replace some parts of the upper femur and acetabulum with biocompatible materials. The main goal of this surgery is to eliminate pain and regain full extent of joint motion, maintaining hip stability. Surgical technique, biomaterials, design of the prosthesis and fixation techniques have evolved with time adjusting to each other. After total hip arthroplasty patients’ quality of life should be improved. There are many various postoperative complications. Some of them are fatal, and some are minor, which may become manifested years after surgery. Each next surgical procedure following previous hip surgery is associated with considerably lower chances to be successful. Therefore, in primary total hip arthroplasty, preoperative evaluation and preparation of patients are essential. Every orthopaedic surgeon needs to improve already adopted surgical skills applying them with precision and without compromise, with the main goal to achieve long-term durability of the selected implant. The number of total hip arthroplasties will also increase in future, and newer and higher quality materials will be used.

  8. Alternative outcome measures in young total hip arthroplasty patients

    DEFF Research Database (Denmark)

    Klit, Jakob; Jacobsen, Steffen; Schmiegelow, Victoria

    2015-01-01

    In this prospective multicentre cohort study we studied subjects younger than 60 years of age scheduled for primary total hip arthroplasty (THA). The study assessed patients' overall satisfaction, fulfillment of preoperative expectations, the effect on socioeconomic parameters, and quality of sex......-life. Questionnaires including Oxford Hip Score (OHS) and SF-36 were evaluated preoperatively and 3, 6 and 12 months postoperatively. OHS and SF-36 showed significant improvements (ppatients' socioeconomic status. Increased frequency of intercourse or better...... abilities in intercourse positions were experienced by 18 of 39 females due to reduced pain and increased range of motion. Patients sexually active before THA surgery remained active. These findings constitute important new information to young patients and surgeons during the decision making process....

  9. Total Hip Arthroplasty in Patients with Cerebral Palsy: A Cohort Study Matched to Patients with Osteoarthritis.

    Science.gov (United States)

    Houdek, Matthew T; Watts, Chad D; Wyles, Cody C; Trousdale, Robert T; Milbrandt, Todd A; Taunton, Michael J

    2017-03-15

    The spasticity and increased muscle tone observed in patients with cerebral palsy can lead to hip degeneration, subluxation, and pain. Currently, there is hesitation to perform total hip arthroplasty in patients with cerebral palsy because of fears of early wear and dislocation. The purpose of this study was to review the outcomes of total hip arthroplasty in patients with cerebral palsy and to compare outcomes with those of matched patients with a diagnosis of osteoarthritis. Over a 24-year period, 39 patients undergoing a total hip arthroplasty with a diagnosis of cerebral palsy were identified. The cohort included 26 male patients (67%), and the mean patient age was 49 years. The mean follow-up was 7 years. Patients with cerebral palsy were matched 1:2 with a group of patients undergoing total hip arthroplasty for osteoarthritis. There was no difference in the rate of reoperation, implant survival, or complications, specifically dislocation. Prior to the surgical procedure, all patients had severe or moderate pain, and postoperatively no patient had moderate or severe pain. Twenty-three patients had an improvement in their ability to independently walk, and all preoperative hip flexion contractures were corrected (n = 9). There was also a significant improvement (p cerebral palsy. Total hip arthroplasty is a durable treatment option and provides clinically important pain relief and functional improvement in patients with cerebral palsy. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  10. Results of hip arthroplasty using Paavilainen technique in patients with congenitally dislocated hip

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2014-01-01

    Full Text Available The purpose of the study was to analyze the medium- and long-term results of hip arthroplasty using Paavilainen technique in patients with the congenitally dislocated hip. Methods: From 2001 to 2012 180 operations were carried out were using the Paavilainen technique in 140 patients with high dislocation of the hip (Crowe IV. All patients were clinically evaluated using the Harris Hip Score (HHS, VAS and radiography. Statistical analysis was performed using the Pearson correlation coefficients, multiple regression analysis and classification trees analysis. Results: The average Harris score improved from preoperative 41.6 (40,3-43,5 to 79.3 (77,9-82,7 at final follow-up, and the difference was significant. Early complications were 9% (the most frequent were fractures of the proximal femur, later - 16.7% (pseudoarthrosis of the greater trochanter, 13.9%; disclocations-1,1%, aseptic loosening of the components - 1.7%, reoperation performed in 8.3% of cases. Such factors as age and limb length has statistically significant effect on functional outcomes. Established predictive model allows to get the best possible functional outcome in such patients with severe dysplasia. Conclusions: Total Hip arthroplasty using the Paavilainen technique is an effective method of surgical treatment in patients with the congenitally dislocated hip, but it is technically difficult operation with a high incidence of complications in comparison with standard primary total hip replacement.

  11. The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients

    Directory of Open Access Journals (Sweden)

    Haviv Barak

    2010-07-01

    Full Text Available Abstract Objective To assess the incidence of total hip arthroplasty (THA in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA. Design Retrospective clinical series Methods Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years. The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis. Results Ninety (16% of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA. Conclusions In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures.

  12. Patients' perception of leg length discrepancy post total hip arthroplasty.

    Science.gov (United States)

    Sykes, Alice; Hill, Janet; Orr, John; Humphreys, Patricia; Rooney, Aidan; Morrow, Esther; Beverland, David

    2015-01-01

    Perception of a leg length discrepancy post total hip arthroplasty (THA) is one of the most common sources of patient dissatisfaction and can have a direct influence on the considered success of the operation.This research examined postoperative perception of imposed limb discrepancies in a group of THA patients compared to a group of participants with no previous hip surgery. Two subgroups of THA patients were involved: those who did not perceive a difference in limb length following THA and those that did.Discrepancies were imposed in 2.5 mm increments. For discrepancies ≥5 mm, a significant number of participants were aware of a difference (74%). There was no significant difference in perception of imposed discrepancies between THA patients and participants with no previous hip surgery. THA patients who perceived a difference in their limb lengths postoperatively had significantly worse pain and oxford scores when compared to THA patients who perceived their limb lengths to be equal. Knowing the boundaries between LLDs that go undetected and those that patients are aware of could guide surgeons when evaluating the balance between correct soft tissue tension and the resulting unequal leg length. From these findings, discrepancies >5 mm are likely to be perceived. Whether this perception would lead directly to a negative outcome score and patient dissatisfaction is more complex to project and likely to be patient specific. Intraoperative methods to aid the controlled positioning of implanted components could help maintain and restore leg length to within an acceptable amount that patients cannot perceive.

  13. Pigmented Villonodular Synovitis in a Patient who Underwent Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Nevzat Dabak

    2014-09-01

    Full Text Available Pigmented villonodular synovitis (PVNS is a rare, benign, but a locally aggressive tumor. It is characterized by the proliferation of synovial membrane, but it can also be seen in tendon sheaths and bursae. Clinical presentation of solitary lesions include compression and locking of the joint suggesting loose bodies in the joint and a subsequent findings of an effusion, whereas diffuse lesions manifest with pain and chronic swelling. In this article, we presented a curious case of PVNS in a female patient who have been followed up due to an acetabular cystic lesion. She underwent total hip arthroplasty for severe osteoarthritis of the hip joint and associated pain. The diagnosis of PVNS was established intraoperatively. (The Me­di­cal Bul­le­tin of Ha­se­ki 2014; 52: 235-7

  14. Comparison of patient and surgeon expectations of total hip arthroplasty.

    Directory of Open Access Journals (Sweden)

    Claire Jourdan

    Full Text Available OBJECTIVES: Analysis of discrepancies between patient and surgeon expectations before total hip arthroplasty (THA should enable a better understanding of motives of dissatisfaction about surgery, but this question has been seldom studied. Our objectives were to compare surgeons' and patients' expectations before THA, and to study factors which affected surgeon-patient agreement. METHODS: 132 adults (mean age 62.8+/-13.7 years, 52% men on waiting list for THA in three tertiary care centres and their 16 surgeons were interviewed to assess their expectations using the Hospital for Special Surgery Total Hip Replacement Expectations Survey (range 0-100. Patients' and surgeons' answers were compared, for the total score and for the score of each item. Univariate analyses tested the effect of patients' characteristics on surgeons' and patients' expectations separately, and on surgeon-patient differences. RESULTS: Surgeon and patient expectations' mean scores were high (respectively 90.9+/-11.1 and 90.0+/-11.6 over 100. Surgeons' and patients' expectations showed no systematic difference, but there was little agreement on Bland and Altman graph and correlation coefficient was low. Patients had higher expectations than surgeons for sports. Patients rated their expectations according to trust in physician and mental quality of life, surgeons considered disability. More disabled patients and patients from a low-income professional category were often "more optimistic" than their surgeons. CONCLUSION: Surgeons and patients often do not agree on what to expect from THA. More disabled patients expect better outcomes than their surgeons.

  15. Hip arthroplasty in patients with complex femoral deformity after surgical treatment of dysplasia

    OpenAIRE

    V. V. Bliznyukov; R. M. Tikhilov; I. I. Shubnyakov; A. O. Denisov; V. A. Shilnikov; A. Z. Chernyi; S. S. Bilyk

    2014-01-01

    Objective - based on the analysis of remote results of total hip arthroplasty in patients with complex deformities of the femur to compare the effectiveness of operations with standard cases and identify the factors that determine the surgery effectiveness. Material and methods. in Vreden clinic 73 patients with complex deformities of the femur underwent surgical treatment between 2001 and 2013 by various surgical interventions: arthroplasty without femoral osteotomy (23); arthroplasty accomp...

  16. A randomised controlled trial of total hip arthroplasty versus resurfacing arthroplasty in the treatment of young patients with arthritis of the hip joint

    Directory of Open Access Journals (Sweden)

    Griffin Damian R

    2010-01-01

    Full Text Available Abstract Background Hip replacement (arthroplasty surgery is a highly successful treatment for patients with severe symptomatic arthritis of the hip joint. For older patients, several designs of Total Hip Arthroplasty have shown excellent results in terms of both function and value for money. However, in younger more active patients, there is approximately a 50% failure rate at 25 years for traditional implants. Hip resurfacing is a relatively new arthroplasty technique. In a recent review of the literature on resurfacing arthroplasty it was concluded that the short-term functional results appear promising but some potential early disadvantages were identified, including the risk of femoral neck fracture and collapse of the head of the femur.The aim of the current study is to assess whether there is a difference in functional hip scores at one year post-operation between Total Hip Arthroplasty and Resurfacing Arthroplasty. Secondary aims include assessment of complication rates for both procedures as well cost effectiveness. Methods/design All patients medically fit for surgery and deemed suitable for a resurfacing arthroplasty are eligible to take part in this study. A randomisation sequence will be produced and administered independently. After consenting, all patients will be clinically reviewed and hip function, quality of life and physical activity level will be assessed through questionnaires. The allocated surgery will then be performed with the preferred technique of the surgeon. Six weeks post-operation hip function will be assessed and complications recorded. Three, six and 12 months post-operation hip function, quality of life and physical activity level will be assessed. Additional information about patients' out-of-pocket expenses will also be collected. Trial registration Current Controlled Trials ISRCTN33354155 UKCLRN portfolio ID 4093

  17. Revision hip arthroplasty in patients with a previous total hip replacement for osteonecrosis of the femoral head.

    Science.gov (United States)

    Park, Youn-Soo; Moon, Young-Wan; Lee, Keun-Ho; Lim, Seung-Jae

    2014-12-01

    Patients with osteonecrosis of the femoral head are typically relatively young and active and often require high rates of revision after primary total hip arthroplasty. However, outcomes of revision hip arthroplasty in this patient population have rarely been reported in the literature. The authors conducted a retrospective review of 72 patients (75 hips) who underwent revision hip arthroplasty with a primary diagnosis of osteonecrosis of the femoral head. Mean age at index revision was 53.3 years (range, 34-76). Components of acetabular revision included a cementless porous-coated cup in 58 hips and an acetabular cage in 3 hips. Components of femoral revision included a fully grit-blasted tapered stem in 30 hips and a proximally porous-coated modular stem in 9 hips. Mean duration of follow-up was 7 years (range, 3-17). Mean Harris Hip Score improved from 49 points preoperatively to 90 points postoperatively. At final follow-up, 11 hips (14.7%) required reoperation because of aseptic loosening (6 hips), infection (2 hips), recurrent dislocation (1 hip), periprosthetic fracture (1 hip), and ceramic fracture (1 hip). Kaplan-Meier survivor-ship with an endpoint of re-revision for any reason was 81% and for mechanical failure was 87.5% for the cup and 100% for the stem at 10 years. Unlike the previous report, the authors' study showed a lower failure rate of the femoral stem after revision hip arthroplasty using modern cementless femoral components in patients with osteonecrosis of the femoral head. Aseptic cup loosening or osteolysis is the most common mechanism of failure at medium-term follow-up. Copyright 2014, SLACK Incorporated.

  18. An Insight into Methods and Practices in Hip Arthroplasty in Patients with Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    Mohammad Saeed Mosleh-shirazi

    2015-01-01

    Full Text Available Total hip arthroplasty (THA has improved the quality of life of patients with hip arthritis. Orthopedic community is striving for excellence to improve surgical techniques and postoperative care. Despite these efforts, patients continue facing postoperative complications. In particular, patients with rheumatoid arthritis display a higher risk of certain complications such as dislocation, periprosthetic infection, and shorter prosthesis durability. In this review we present the current knowledge of hip arthroplasty in patients with rheumatoid arthritis with more insight into common practices and interventions directed at enhancing recovery of these patients and current shortfalls.

  19. Imaging of hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Theodore T., E-mail: millertt@hss.edu [Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021 (United States)

    2012-12-15

    The imaging evaluation of the prosthetic hip begins with radiography, but arthrography, aspiration, scintigraphy, sonography, CT and MR imaging all have roles in the evaluation of the painful prosthesis. This article will review the appearance of normal hip arthroplasty including hemiarthroplasty, total arthroplasty, and hip resurfacing, as well as the appearances of potential complications such as aseptic loosening and osteolysis, dislocation, infection, periprosthetic fracture, hardware failure, and soft tissue abnormalities.

  20. Total hip arthroplasty for patients with osteoarthritis secondary to hip pyogenic infection

    Institute of Scientific and Technical Information of China (English)

    GAO Xiang; HE Rong-xin; YAN Shi-gui

    2010-01-01

    Background Pyogenic hip arthritis occurs most often in young patients. Delayed treatment causes significant anatomical deformation of bony and soft tissue structures leading to premature onset of secondary osteoarthritis. Total hip arthroplasty (THA) in patients who had osteoarthritis secondary to hip pyogenic infection has been associated with high complication rates. Methods We analyzed 19 THAs performed from April 2003 to July 2008 in adults with osteoarthritis secondary to hip pyogenic infection (average age 40.7 years; range 34-52 years). There were 7 males and 12 females, the average age of infection was 10.6 years (range 7-13 years) and the average quiescent period of infection was 29.5 years (range 22-41 years). The count of white blood cell (WBC), erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) were examined routinely before surgery. The duration of followup was 34 months (range 6-52 months). Conclusions It is safe and efficient to perform THA in patients who had osteoarthritis secondary to pyogenic hip arthritis when the infection is quiescent. The key points of successful surgery are exclusion of active infection preoperatively, quiescent period of infection more than ten years and adequate intraoperative soft tissue releases.

  1. Prevalence of pseudotumor in asymptomatic patients after metal-on-metal hip arthroplasty.

    Science.gov (United States)

    Williams, Daniel H; Greidanus, Nelson V; Masri, Bassam A; Duncan, Clive P; Garbuz, Donald S

    2011-12-07

    The cause of recently reported pseudotumor formation in patients with metal-on-metal hip replacements is unknown. It has been postulated that there is an association between elevated levels of serum metal ions and pseudotumor formation. The primary purpose of this study was to assess the prevalence of pseudotumor formation in asymptomatic patients with a metal-on-metal total hip replacement after a minimum duration of follow-up of two years. A secondary purpose was to assess whether a correlation exists between elevated serum metal ion levels and pseudotumor formation. In the present study, the prevalence of pseudotumor formation, as detected with ultrasound, was evaluated for thirty-one asymptomatic patients with a metal-on-metal total hip arthroplasty, twenty-four asymptomatic patients with a metal-on-polyethylene total hip arthroplasty, and twenty asymptomatic patients with a metal-on-metal hip resurfacing arthroplasty. Serum levels of cobalt and chromium were measured in the metal-on-metal total hip arthroplasty and hip resurfacing arthroplasty groups. Ten patients (32%) in the metal-on-metal total hip arthroplasty group had a solid or cystic mass, with another three patients (10%) having a substantial fluid collection. Five patients (25%) in the hip resurfacing arthroplasty group had a solid or cystic mass, with another patient (5%) having a fluid collection. Pseudotumor formation was significantly more frequent in the metal-on-metal total hip arthroplasty group compared with the metal-on-polyethylene total hip arthroplasty group (p = 0.015). We did not detect a significant correlation between the serum metal ion levels and the size of pseudotumor abnormality. The median serum metal ion level was greater in patients with pseudotumor formation than it was in those without pseudotumor formation, but the difference was not significant. We recommend high-resolution ultrasound surveillance of all asymptomatic patients with a metal-on-metal implant that is known to

  2. Revision of hip resurfacing arthroplasty.

    Science.gov (United States)

    Wera, Glenn D; Gillespie, Robert J; Petty, Carter; Petersilge, William J; Kraay, Matthew J; Goldberg, Victor M

    2010-08-01

    Metal-on-metal (MOM) hip resurfacing has become an increasingly popular treatment for young, active patients with degenerative disease of the hip, as bearing surfaces with better wear properties are now available. One proposed advantage of resurfacing is its ability to be successfully revised to total hip arthroplasty (THA). In addition, radiographic parameters that may predict failure in hip resurfacing have yet to be clearly defined. Seven MOM resurfacing arthroplasties were converted to conventional THAs because of aseptic failure. Using Harris Hip Scores (HHS) and Short Form 12 (SF-12) questionnaire scores, we compared the clinical outcomes of these patients with those of patients who underwent uncomplicated MOM hip resurfacing. In addition, all revisions were radiographically evaluated. Mean follow-up periods were 51 months (revision group) and 43 months (control group). There was no significant difference between the 2 groups' HHS or SF-12 scores. There was no dislocation or aseptic loosening after conversion of any resurfacing arthroplasty. Valgus neck-shaft angle (P hip resurfacing. Conversion of aseptic failure of hip resurfacing to conventional THA leads to clinical outcomes similar to those of patients who undergo uncomplicated hip resurfacing. The orientation of the femur and the components placed play a large role in implant survival in hip resurfacing. More work needs to be done to further elucidate these radiographic parameters.

  3. Patient-reported outcome after total hip arthroplasty: comparison between lateral and posterior approach

    DEFF Research Database (Denmark)

    Rosenlund, Signe; Broeng, Leif; Larsen, Anders Holsgaard

    2017-01-01

    . In this randomized controlled trial, we tested the hypothesis that patient-reported outcomes are better in patients who have undergone total hip arthroplasty (THA) with PA than in those who have undergone THA with LA, 12 months postoperatively. Patients and methods — 80 patients with hip osteoarthritis (mean age 61......Background and purpose — Criticism of the lateral approach (LA) for hip arthroplasty is mainly based on the risk of poor patient-reported outcomes compared to the posterior approach (PA). However, there have been no controlled studies comparing patient-reported outcomes between them......-Pain, HOOS-Quality-Of-Life, EQ-5D, UCLA Activity Score, and limping. Results — We found no statistically signifi cant difference in the improvements in HOOS-PS between the treatment groups at 12-month follow-up. All secondary outcomes showed similar results except for limping, where PA patients improved...

  4. Hip Resurfacing Arthroplasty and Perioperative Blood Testing

    Directory of Open Access Journals (Sweden)

    Andrew Cook

    2014-01-01

    Full Text Available It is standard practice in many institutions to routinely perform preoperative and postoperative haemoglobin level testing in association with hip joint arthroplasty procedures. It is our observation, however, that blood transfusion after uncomplicated primary hip arthroplasty in healthy patients is uncommon and that the decision to proceed with blood transfusion is typically made on clinical grounds. We therefore question the necessity and clinical value of routine perioperative blood testing about the time of hip resurfacing arthroplasty. We present analysis of perioperative blood tests and transfusion rates in 107 patients undertaking unilateral hybrid hip resurfacing arthroplasty by the senior author at a single institution over a three-year period. We conclude that routine perioperative testing of haemoglobin levels for hip resurfacing arthroplasty procedures does not assist in clinical management. We recommend that postoperative blood testing only be considered should the patient demonstrate clinical signs of symptomatic anaemia or if particular clinical circumstances necessitate.

  5. Center of Mass Compensation during Gait in Hip Arthroplasty Patients: Comparison between Large Diameter Head Total Hip Arthroplasty and Hip Resurfacing

    Directory of Open Access Journals (Sweden)

    Vicky Bouffard

    2011-01-01

    Full Text Available Objective. To compare center of mass (COM compensation in the frontal and sagittal plane during gait in patients with large diameter head total hip arthroplasty (LDH-THA and hip resurfacing (HR. Design. Observational study. Setting. Outpatient biomechanical laboratory. Participants. Two groups of 12 patients with LDH-THA and HR recruited from a larger randomized study and 11 healthy controls. Interventions. Not applicable. Main Outcome Measures. To compare the distance between the hip prosthetic joint center (HPJC and the COM. The ratio (RHPJC-COM and the variability (CVHPJC-COM were compared between groups. Hip flexor, abductor, and adductor muscle strength was also correlated between groups while radiographic measurements were correlated with the outcome measures. Results. In the frontal plane, HR shows less variability than healthy controls at push-off and toe-off and RHPJC-COM is correlated with the muscle strength ratios (FRABD at heel contact, maximal weight acceptance, and mid stance. In the sagittal plane, LDH-THA has a higher RHPJC-COM than healthy controls at push-off, and CVHPJC-COM is significantly correlated with FRFLEX. Conclusions. One year after surgery, both groups of patients, LDH-THA and HR, demonstrate minor compensations at some specific instant of the gait cycle, in both frontal and sagittal planes. However, their locomotion pattern is similar to the healthy controls.

  6. Physical Activity Participation Among Patients After Total Hip and Knee Arthroplasty

    NARCIS (Netherlands)

    Stevens, Martin; Reininga, Inge H. F.; Bulstra, Sjoerd K.; Wagenmakers, Robert; van den Akker-Scheek, Inge

    2012-01-01

    Total hip (THA) and knee arthroplasty (TKA) are successful operative interventions, yet little is known about the physical activity behavior of patients after THA/TKA. For older adults, there are beneficial effects of regular physical activity after THA/TKA. The objective of this paper is to review

  7. Quantifying gait quality in patients with large-head and conventional total hip arthroplasty

    DEFF Research Database (Denmark)

    Jensen, Carsten; Penny, Jeannette Østergaard; Nielsen, Dennis Brandborg;

    2015-01-01

    We used the Gait Deviation Index (GDI) as method to compare preoperative to postoperative gait changes after uncemented 50mm(median) large-head and 28/32mmtotal hip arthroplasty (THA). We also identified predictors of improvements in GDI. Gait analysis and patient-reported (WOMAC) datawere record...

  8. Delirium after fast-track hip and knee arthroplasty - a cohort study of 6331 elderly patients

    DEFF Research Database (Denmark)

    Petersen, P B; Jørgensen, C C; Kehlet, H

    2017-01-01

    BACKGROUND: Postoperative delirium (PD) is a well-known complication among elderly surgical patients and associated with increased morbidity, mortality and length of stay (LOS). In elective orthopedic surgery, including hip and knee arthroplasty (THA/TKA), most studies report incidences between 5...... without PD (P delirium symptoms contributing to LOS > 4 days in fast...

  9. [Uncemented arthroplasty of the hip].

    Science.gov (United States)

    von Schulze Pellengahr, C; Fottner, A; Utzschneider, S; Schmitt-Sody, M; Teske, W; Lichtinger, T; Esenwein, S A

    2009-05-01

    Prognosis of cemented total hip replacement seems to be excellent for elderly patients. In younger age the outcome is less favourable and early revision is more common. Thus, different concepts with better prognosis and preservation of bone stock for possible revisions were needed. After more than 30 years of application with excellent short-term and long-term results, uncemented total hip arthroplasty is nowadays generally regarded as the standard procedure for younger patients. New bone-preserving implants, such as surface replacement or short-stemmed femoral shaft prostheses, have been introduced especially for younger patients. Some of these new procedures are still under development, and the long-term results of new implant concepts have to be evaluated over the next decades. Regarding recently published scientific studies an overview about non-cemented total hip arthroplasty is given and current concepts and developments are presented.

  10. Patients report improvement in quality of life and satisfaction after hip resurfacing arthroplasty.

    Science.gov (United States)

    Rahman, Wael A; Greidanus, Nelson V; Siegmeth, Alexander; Masri, Bassam A; Duncan, Clive P; Garbuz, Donald S

    2013-02-01

    A number of reconstructive procedures are available for the management of hip osteoarthritis. Hip resurfacing arthroplasty is now an accepted procedure, with implant survivorship comparable to THA at up to 10 years' followup in certain series. Most reports focus on implant survivorship, surgeon-derived results, or complications. Fewer data pertain to patient-reported results, including validated measures of quality of life (QoL) and satisfaction and baseline measures from which to determine magnitude of improvement. Validated patient-reported results are essential to guide patients and surgeons in the current era of informed and shared decision making. We determined whether patients reported improvement in disease-specific, joint-specific, and generic QoL after hip resurfacing arthroplasty; whether patients were satisfied with the results of the procedure; and latest activity level and return to sport. We retrospectively reviewed 127 patients (100 men, 27 women) who underwent 143 hip resurfacing procedures between 2002 and 2006. Mean patient age was 52 years. Patients completed the WOMAC, Oxford Hip Score, and SF-12 at baseline and again at minimum 2-year followup (mean, 2.5 years; range, 2-6 years). At latest followup, patients completed a validated satisfaction questionnaire and UCLA activity score. All QoL scores improved (normalized to a 0-100 scale, where 100 = best health state). WOMAC improved from 46 to 95, Oxford Hip Score from 42 to 95, SF-12 (physical) from 34 to 54, and SF-12 (mental) from 46 to 56. Patient satisfaction score was 96. UCLA activity score was 8. The majority of patients reported improvement in QoL, were very satisfied with their outcome, and returned to a high level of activity after hip resurfacing arthroplasty. Level IV, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.

  11. A prospective comparative study of cementless total hip arthroplasty and hip resurfacing in patients under the age of 55 years: a ten-year follow-up.

    Science.gov (United States)

    Haddad, F S; Konan, S; Tahmassebi, J

    2015-05-01

    The aim of this study was to evaluate the ten-year clinical and functional outcome of hip resurfacing and to compare it with that of cementless hip arthroplasty in patients under the age of 55 years. Between 1999 and 2002, 80 patients were enrolled into the study: 24 were randomised (11 to hip resurfacing, 13 to total hip arthroplasty), 18 refused hip resurfacing and chose cementless total hip arthroplasty with a 32 mm bearing, and 38 insisted on resurfacing. The mean follow-up for all patients was 12.1 years (10 to 14). Patients were assessed clinically and radiologically at one year, five years and ten years. Outcome measures included EuroQol EQ5D, Oxford, Harris hip, University of California Los Angeles and University College Hospital functional scores. No differences were seen between the two groups in the Oxford or Harris hip scores or in the quality of life scores. Despite a similar aspiration to activity pre-operatively, a higher proportion of patients with a hip resurfacing were running and involved in sport and heavy manual labour after ten years. We found significantly higher function scores in patients who had undergone hip resurfacing than in those with a cementless hip arthroplasty at ten years. This suggests a functional advantage for hip resurfacing. There were no other attendant problems.

  12. The effect of cold therapy on the postoperative course of total hip and knee arthroplasty patients.

    Science.gov (United States)

    Scarcella, J B; Cohn, B T

    1995-11-01

    Fifty total hip arthroplasty (THA) patients and 24 total knee arthroplasty (TKA) patients were randomized in a controlled study to examine the effects of cold therapy (via thermal blankets) in the postoperative period. The postoperative hospital stay was significantly shorter for the cold-therapy (50 degrees F) compared with control (70 degrees F) groups (by 1.4 days, P = 0.03) for THA patients. There was a similar but nonsignificant trend observed in the TKA groups (1.5 days shorter, P = 0.19). Total knee arthroplasty patients using cold therapy achieved independent ambulation an average of 1 day sooner than TKA control patients, but this difference did not reach statistical significance (P = 0.08). There were no statistically significant differences between the control groups or the test groups for both THA and TKA patients in narcotic usage, postoperative range-of-motion (ROM), or rate of progression of ROM.

  13. Wear debris in cemented total hip arthroplasty.

    Science.gov (United States)

    Huo, M H; Salvati, E A; Buly, R L

    1991-03-01

    One of the most prevalent clinical problems in long-term follow up of total hip arthroplasty patients is loosening of prosthetic fixation. Factors contributing to mechanical failure of total hip reconstruction are complex and multiple. It has become increasingly apparent that wear debris from the prosthetic components may contribute significantly to this process. The authors summarize some of the current concepts concerning the detrimental effects of metallic debris in total hip arthroplasty.

  14. The Consumer Quality Index Hip Knee Questionnaire measuring patients' experience with quality of care after a total hip or knee arthroplasty.

    NARCIS (Netherlands)

    Stubbe, J.H.; Gelsema, T.; Delnoij, D.M.J.

    2007-01-01

    Background: The Dutch Consumer Quality Index Hip Knee Questionnaire (CQI Hip Knee) was used to assess patients' experiences with and evaluations of quality of care after a total hip (THA) or total knee arthroplasty (TKA). The aim of this study is to evaluate the construct validity and internal consi

  15. Total hip arthroplasty with cementless cups and femoral head autografts for patients with hip dysplasia and osteoarthritis

    Institute of Scientific and Technical Information of China (English)

    吴立东; 金礼斌; 严世贵; 杨泉森; 戴雪松; 王祥华

    2004-01-01

    Objective:To evaluate the outcome of total hip arthroplasty (THA) with cementless cups and femoral head autografts for patients with hip dysplasia and osteoarthritis.Methods: Between 1995 and 2002, we implanted 23cementless cups and femoral head autografts in 20 patients with hip dysplasia and osteoarthritis. In this study, a retrospective study was made on 21 hips in 20 patients (18females and 2 males, aged 50 years on an average) with developmental hip dysplasia treated by THA with acementless cup and femoral head autograft. The acetabular cup was placed at the level of the true acetabuinm and all the patients required autogenous femoral head grafts due to acetabular deficiency. The average rate of the acetabular cup covered by the femoral head autograft was 31%(ranging from 10% to 45%). Eight hips had less than 25%cup coverage and thirteen between 25% and 50%. The average follow-up period was 4.7 years (range, 1-8 years).The replacing outcome was evaluated by modified Harris hip score. Preoperative and follow-up radiographs were made.Results: All the autografts were united to the host bones. No autograft was collapsed or no component from the hip was loosed in all the patients. According to the modified Harris hip score, the average hip score increased from 46 before operation to 89 at the final review. Before operation, the leg-length discrepancy was greater than 2 cm in all the patients except one with bilateral hip dysplasia.After operation, only 2 out of 20 patients had a leg-length discrepancy greater than 1 cm. Three hips showed minor bone resorption in the lateral portion of the graft, which did not support the cup. Three hips developed Grade 1Brooker heterotopic ossification and one developed Grade 2.Conclusions: THA with a cementless cup and a femoral head autograft for patients with osteoarthritis resulted from hip dysplasia can result in favorable outcomes. This method can provide reliable acetabular fixation and restore the acetabular bone stock in

  16. Arthroplasty in patients with congenital hip dysplasia--early evaluation of a treatment method.

    Science.gov (United States)

    Bożek, Marek; Bielecki, Tomasz; Nowak, Roman; Żelawski, Maciej

    2013-01-01

    Developmental hip dysplasia (DHD) is the most common cause of secondary hip osteoarthritis (OA). It often leads to OA in young, active and working adults. The aim of our study is to evaluate the results of THA in patients with DHD. Total hip arthroplasty was performed in 15 patients with DHD - 13 women (average age - 39) and 2 men (average age - 44) between June 2010 to June 2011. Patient's hips were estimated by Crowe classification to evaluate the severity of degenerative arthritis. Patients we reassessed with Harris Hip Score before and after the surgery. The mean preoperative score was 44.6 points, directly after surgery 62.4 pts., 6 months after 78.6 points. After artrhroplasty, improvement was noted in walking stairs without railing, walking without support, sitting on chair for more than 1 hour. Before the surgery average difference in limbs" length was 4 cm After the treatment it was reduced to 0.5 cm. Mean hip flexion was 40 ° before, 90 ° after the surgery, mean abduction was respectively 0° and 25°. Our study proves that total hip arthroplasty in patients with developmental dysplasia of hip helps to improve stability and mobility of joint and to reduce the pain. 1. In the type 1 and 2 according to Crow's classification, good clinical results may be achieved using standard prosthesis stem sizes and press-fit acebutalar component with possibly the smallest diameter providing stable placing. 2. In the case of ty pe III good results are observed using acetabular press-fit method for fixing, after reconstruction of bone defects with osteogenous bone graft. 3. The usage of big head dimensions gives beneficial effects on the osseointegration of the acetabular component and reduces the risk of dislocation. 4. A short follow-up period of the group of patients presented requires further prospective study to evaluate the long-term results.

  17. Hip arthroplasty in patients with complex femoral deformity after surgical treatment of dysplasia

    Directory of Open Access Journals (Sweden)

    V. V. Bliznyukov

    2014-01-01

    Full Text Available Objective - based on the analysis of remote results of total hip arthroplasty in patients with complex deformities of the femur to compare the effectiveness of operations with standard cases and identify the factors that determine the surgery effectiveness. Material and methods. in Vreden clinic 73 patients with complex deformities of the femur underwent surgical treatment between 2001 and 2013 by various surgical interventions: arthroplasty without femoral osteotomy (23; arthroplasty accompanied by great trochanteric slide osteotomy or Paavilainen technigue (37, arthroplasty with femoral osteotomy below the lesser trochanter (13, including 4 - at the level of deformation, 4 - with double two-stage osteotomy and 5 - with one-stage double osteotomy. all patients were assessed with Harris scale before and after surgery. the results obtained in the course of the study data were processed using statistical methods, including correlation analysis using Pearson's coefficients and Gamma. Results. in assessing the long-term results the Harris hip score improved from a preoperative average of 40.2 (95% Ci 38.2 to 45.6 to 78.4 (95% Ci 76.7 to 83.5. the analysis of various factors influencing on operation efficiency showed that maximum results are achieved with good initial function and a small level of pain (Harris score of 40-45 points, residual femoral deformation should not exceed 5 degrees, the rotation center displacement - no more than 30 mm, the offset increasing - no more than 20 mm and of limb length increasing - no more than 25-30 mm. Conclusion. Hip arthroplasty in patients with coxarthrosis associated with complex femoral deformities is technically challenging, but the using the algorithm presented by authors allows achieve the best possible results.

  18. Heart rate response during sleep in elderly patients after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Krenk, Lene; Sørensen, Gertrud Laura; Kehlet, Henrik

    2015-01-01

    Variability in heart rate response (HRR) can be used as a measure for autonomic nervous system function, which may influence sleep disturbances and the recovery phase after major surgery. The aim of this study was to evaluate autonomic function by assessment of HRR during sleep arousals...... in the postoperative period after fast-track hip and knee arthroplasty. Determination of autonomic function was gained from polysomnographic evaluation of 10 patients >60 years undergoing either hip or knee arthroplasty (mean age 69.9 years) evaluating HRR during the different sleep phases. Sleep monitoring took place...... in the patients' home preoperatively, during hospitalization on the first postoperative night, and on the fourth postoperative night at home. HRR was reduced (P sleep on the first postoperative night, and was still reduced on the fourth postoperative night compared...

  19. [Case report of a patient with ochronosis and arthroplasty of the hip and both knees].

    Science.gov (United States)

    Moslavac, Aleksandra; Moslavac, Sasa; Cop, Renata

    2003-01-01

    Alkaptonuria is a rare hereditary metabolic disorder characterised by absence of the enzyme homogentisic acid oxidase. As a result of this defect homogentisic acid accumulates and is excreted in the urine. The term ochronosis is used to describe bluish-black pigmentation of connective tissue. Ochronotic arthropathy results from the pigmented deposits in the joints of the appendicular and axial skeleton. Findings simulate those of uncomplicated degenerative joint disease, with effusion, articular space narrowing, and bony sclerosis. Our patient is a 70-year old male with ochronotic arthropathy. He has typical ears and sclera discoloration, and had arthroplasty of knees 7 and 4 years ago, respectively. In year 2002, he had undergone total right hip arthroplasty and has been admitted for rehabilitation 14th postoperative day. Individually designed rehabilitation regimen included kinesitherapy, hydrokinesitherapy, and ambulation training with gradual increase in weight bearing exercises and electro-analgesia of associated low back pain. In course of rehabilitation our patient improved his endurance with satisfying range of motion of right hip (flexion 90 degrees, abduction 40 degrees) and strength of hip and thigh musculature. The patient was able to walk with crutches without limitation. We conclude that joint destruction followed by painful locomotion due to ochronotic arthropathy is best treated by total joint arthroplasty, as described in our patient.

  20. Minimally Invasive Total Hip and Knee Arthroplasty-Implications for the Elderly Patient

    NARCIS (Netherlands)

    Reininga, Inge H. F.; Stevens, Martin; Wagenmakers, Robert; Bulstra, Sjoerd K.; van den Akker-Scheek, Inge

    2012-01-01

    Total hip arthroplasty and total knee arthroplasty have proven to be effective surgical procedures for the treatment of hip and knee osteoarthritis. In recent decades, there have been considerable efforts to improve the component designs, modes of fixation, and surgical techniques. Minimally invasiv

  1. Cirrhosis patients have increased risk of complications after hip or knee arthroplasty

    DEFF Research Database (Denmark)

    Deleuran, Thomas; Vilstrup, Hendrik; Overgaard, Søren

    2015-01-01

    Background and purpose: The risk of complications in cirrhosis patients after orthopedic surgery is unclear. We examined this risk after total hip arthroplasty (THA) or total knee arthroplasty (TKA). Patients and methods: Using Danish healthcare registries, we identified all Danish residents who...... underwent a THA or TKA for primary osteoarthritis in the period 1995-2011. We compared the risk of complications in patients with or without cirrhosis. Results: The surgical technique was similar in the 363 cirrhosis patients and in 109,159 reference patients, but cirrhosis patients were more likely to have...... been under general anesthesia (34% vs. 23%), were younger (median age 66 vs. 69 years), had a predominance of males (54% vs. 41%), had more comorbidity, and had had more hospitalizations preoperatively. Their risk of intraoperative complications was similar to that for reference patients (2.5% vs. 2...

  2. CURBSIDE CONSULTATION IN HIP ARTHROPLASTY

    OpenAIRE

    Sporer, Scott M.; Bernard R. Bach, Jr

    2009-01-01

    DESCRIPTION A user friendly reference for decision making in hip arthroplasty designed in a question formed clinical problem scenarios and answers format .The articles composed of the answers, containing current concepts and preferences of experts in primary and revision hip surgery are enhanced by several images, diagrams and references and written in the form of a curbside consultation by Scott M. Sporer, MD. and his collaborators. PURPOSE By this practical reference of hip arthroplasty, Sc...

  3. Congenital hip dysplasia treated by total hip arthroplasty using cementless tapered stem in patients younger than 50 years old: results after 12-years follow-up.

    Science.gov (United States)

    Faldini, Cesare; Miscione, Maria Teresa; Chehrassan, Mohammadreza; Acri, Francesco; Pungetti, Camilla; d'Amato, Michele; Luciani, Deianira; Giannini, Sandro

    2011-12-01

    Congenital hip dysplasia may lead to severe acetabular and femoral abnormalities that can make total hip arthroplasty a challenging procedure. We assessed a series of patients affected by developmental hip dysplasia treated with total hip arthroplasty using cementless tapered stem and here we report the outcomes at long-term follow-up. Twenty-eight patients (24 women and 4 men) aged between 44 and 50 years (mean 47 years) were observed. Clinical evaluation was rated with the Harris Hip Score. Radiographic evaluation consisted in standard anteroposterior and axial view radiographs of the hip. According to Crowe's classification, 16 hips presented dysplasia grade 1, 14 grade 2, and 4 grade 3. All patients were treated with total hip arthroplasty using a cementless tapered stem (Wagner Cone Prosthesis). Six patients were operated bilaterally, with a totally of 34 hips operated. After surgery, the patients were clinically and radiographically checked at 3, 6, and 12 months and yearly thereafter until an average follow-up of 12 years (range 10-14 years). Average Harris Hip Score was 56 ± 9 (range 45-69) preoperatively, 90 ± 9 (range 81-100) 12 months after surgery, and 91 ± 8 (range 83-100) at last follow-up. Radiographic evaluation demonstrated excellent osteointegration of the implants. Signs of bone resorption were present in 6 hips, nevertheless no evidence of loosening was observed and none of the implants has been revised. Even in dysplasic femur, the tapered stem allowed adequate stability and orientation of the implant. We consider tapered stem a suitable option for total hip arthroplasty in developmental hip dysplasia, also in case of young patients, thanks to the favourable long-term results.

  4. Total hip arthroplasty using a cylindrical cementless stem in patients with a small physique.

    Science.gov (United States)

    Nakamura, Yoshihide; Mitsui, Hiromasa; Kikuchi, Akira; Toh, Satoshi; Katano, Hiroshi

    2011-01-01

    We performed total hip arthroplasty using an anatomic medullary locking cementless stem for small-physique patients from 1988 to 1995. We conducted a retrospective study of 50 joints in 44 cases, including 40 developmentally dysplastic hips followed for 12 to 20 years (average, 15.1 years). Average height and body weight were 152 cm and 56 kg (5.0 ft and 124 lb), respectively, with an average body mass index of 24.2. Twelve joints (24%) were revised for acetabular-sided failures. Forty-eight stems (96%) showed bone ingrowth fixation, and there were no unstable stems. The simple cylindrical shape of the distal portion of the AML stem was less affected by deformity of the proximal femur of developmental dysplasia of the hip in patients with a small physique, and both clinically and radiologically good results were confirmed at long-term follow-up.

  5. Total hip arthroplasty in a patient with congenital insensitivity to pain: a case report

    Directory of Open Access Journals (Sweden)

    Erdil Mehmet

    2012-07-01

    Full Text Available Abstract Introduction Congenital insensitivity to pain, a rare neurological entity, is characterized by varying degrees of sensory loss and autonomic dysfunction. Orthopedic manifestations of congenital insensitivity to pain include delayed diagnosis of fractures, nonunions, malunions, Charcot arthropathy, acro-osteolysis, avascular necrosis, osteomyelitis, heterotopic ossification and joint dislocations. We here report the case of a patient with congenital insensitivity to pain who had multiple lower extremity fractures at varying intervals, the most recent being a femoral neck fracture managed by total hip replacement. To the best of our knowledge, this is the first report of cementless hip arthroplasty in such a patient. Case presentation A 37-year-old Caucasian woman was admitted to our hospital complaining of painless swellings in her lower limb and limping. She had been diagnosed with multiple lower extremity fractures at different times. On physical examination, we found multiple perioral mucosal ulcers, shortening of her nails and acro-osteolysis, a prematurely aged facial appearance, undersized skeletal structure, Charcot arthropathy of her right ankle, anosmia, insensitivity to temperature differences and evidence of mild intellectual disability. A right subtrochanteric femur fracture was treated with an intramedullary nail. Eighteen months later, she presented with similar symptoms and we diagnosed a right femoral neck fracture. We removed the nail and performed cementless total right hip arthroplasty. Conclusions Congenital insensitivity to pain is a rare condition that is associated with severe orthopedic problems. This case report, which will be of particular interest to orthopedic surgeons, presents several difficulties in the management of patients with congenital insensitivity to pain and notes the importance of close follow-up and early recognition of complications. Cementless total hip arthroplasty may be a good therapeutic

  6. Cementless total hip arthroplasty for patients with Crowe type III or IV developmental dysplasia of the hip: two-stage total hip arthroplasty following skeletal traction after soft tissue release for irreducible hips.

    Science.gov (United States)

    Yoon, Pil Whan; Kim, Jung Il; Kim, Dong Ok; Yu, Cheol Hwan; Yoo, Jeong Joon; Kim, Hee Joong; Yoon, Kang Sup

    2013-09-01

    Total hip arthroplasty (THA) for severe developmental dysplasia of the hip (DDH) is a technically demanding procedure for arthroplasty surgeons, and it is often difficult to reduce the hip joint without soft tissue release due to severe flexion contracture. We performed two-stage THAs in irreducible hips with expected lengthening of the affected limb after THA of over 2.5 cm or with flexion contractures of greater than 30 degrees in order to place the acetabular cup in the true acetabulum and to prevent neurologic deficits associated with acute elongation of the limb. The purpose of this study is to evaluate the outcomes of cementless THA in patients with severe DDH with a special focus on the results of two-stage THA. Retrospective clinical and radiological evaluations were done on 17 patients with Crowe type III or IV developmental DDH treated by THA. There were 14 women and 3 men with a mean age of 52.3 years. Follow-ups averaged 52 months. Six cases were treated with two-stage THA followed by surgical hip liberalization and skeletal traction for 2 weeks. The mean Harris hip score improved from 40.9 to 89.1, and mean leg length discrepancy (LLD) in 13 unilateral cases was reduced from 2.95 to 0.8 cm. In the patients who underwent two-stage surgery, no nerve palsy was observed, and the single one-stage patient with incomplete peroneal nerve palsy recovered fully 4 weeks postoperatively. The short-term clinical and radiographic outcomes of primary cementless THA for patients with Crowe type III or IV DDH were encouraging. Two-stage THA followed by skeletal traction after soft tissue release could provide alternative solutions to the minimization of limb shortenings or LLD without neurologic deficits in highly selected patients.

  7. USING CUSTOM TRIFLANGE IMPLANT IN REVISION HIP ARTHROPLASTY IN PATIENT WITH PELVIC DISCONTINUITY (CASE REPORT

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2016-01-01

    Full Text Available Revision hip arthroplasty rate is growing, and pelvic discontinuity rate ranges from 1% to 5% of acetabular component revision reasons. According to AAOS acetabular defects classification, pelvic discontinuity is fourth type defect in which cranial part of hip bone is separated from caudal part at acetabular level. Usually it occurs from bone loss secondary to osteolysis, infection, fracture or aseptic loosening. There are a lot of techniques for pelvis discontinuity treatment. Published results of bulk allografts and antiprotrusion cages have generally been poor. More preferable methods with acceptable rate of good results are cup-cage systems and custom triflange acetabular components(CTAC. CTACs are designed based on preoperative CT scans to build a custom titanium 3D-printed implant to address the patient's specific bone defect and provide secure fixation in the ilium, pubis, and ischium. We faced pelvic discontinuity, in which extensive iliac bone loss was added to caudal hip bone part medial displacement and pelvic ring deformity, in patient with multiple hip surgeries. Preoperative investigation called into question the possibility of using off-the-shelf hip implants, which could restore the biomechanics of the hip and provide reliable primary fixation at the same time. We present case report of the patient with pelvic discontinuity and massive bone loss treatment using a custom triflange component.

  8. [Short- and medium-term effectivenesses of stemless hip arthroplasty for treating hip joint disease in young and middle-aged patients].

    Science.gov (United States)

    Chen, Qingzhen; Liu, Wuyang; Gao, Hui; Shi, Mingxiang; Lian, Yucai

    2014-09-01

    To summarize the short- and medium-term effectivenesses of stemless hip arthroplasty for treating hip joint disease in young and middle-aged patients. Between June 2005 and December 2010, 25 cases (27 hips) of hip joint disease were treated with stemless hip arthroplasty. There were 17 males (19 hips) and 8 females (8 hips) with an average age of 45.6 years (range, 30-57 years), including 13 left hips, 10 right hips, and 2 bilateral hips. The causes included avascular necrosis of the femoral head (ANFH) secondary to femoral neck fracture in 5 cases (5 hips), ANFH in 15 cases (16 hips), osteoarthritis of the hip joint caused by ankylosing spondylitis in 2 cases (3 hips), osteoarthritis of the hip joint caused by dysplasia of acetabular in 2 cases (2 hips), and rheumatoid arthritis in 1 case (1 hip). The disease duration was 1-17 years (mean, 6.1 years). Before operation, the Harris score was 47.6 ± 14.2. The incision healed by first intention in all patients, and no complications occurred, such as infection, periprosthetic fracture, and deep vein thrombosis of lower extremity. Twenty-five patients (27 hips) were followed up 36-96 months (mean, 51 months). One case (1 hip) had sciatic nerve injury after operation, which was relieved by symptomatic treatment. One case (1 hip) had prosthesis loosening, which was relieved after revision. The survival rate of prosthesis was 96.3% (26/27). At last follow-up, the Harris score was 92.1 ± 3.6, which was significantly better than preoperative score (t = 18.241, P = 0.000). The excellent and good rate was 88.9% (excellent in 19 hips, good in 5 hips, fair in 2 hips, and poor in 1 hip). The X-ray films showed good location of prosthesis, and no evidence of dislocation, bone resorption, osteolysis, and heterotopic ossification. Because of reserving femoral neck, biomechanics conduction and distribute of the proximal femur achieve natural biomechanics state of the human body. The short- and medium-term effectivenesses of

  9. Risk Factors of Heterotopic Ossification Following Total Hip Arthroplasty in Patients With Ankylosing Spondylitis.

    Science.gov (United States)

    Thilak, Jai; Panakkal, Jiss Joseph; Kim, Tae-Young; Goodman, Susan M; Lee, Sang-Soo; Salvati, Eduardo A

    2015-12-01

    This study was to identify the risk factors of heterotopic ossification (HO) after total hip arthroplasty (THA) in ankylosing spondylitis. We analyzed 47 hips (24 patients) with ankylosing spondylitis that underwent primary THA. The incidence of HO was 14.9%. The risk factors were divided into modifiable and nonmodifiable factors. Female gender (P=0.008), preoperative ankylosed hip (P<0.001), occurrence of HO in previous surgery (P=0.036) were nonmodifiable risk factors which increased the prevalence of HO. Of the various modifiable risk factors, elevated preoperative ESR (P=0.007), elevated preoperative CRP (P=0.004) and prolonged duration of surgery (P=0.014) were associated with increased occurrence of HO. Perioperative medical intervention to reduce inflammation (ESR and CRP) may help to decrease HO.

  10. International metal-on-metal multidisciplinary teams: do we manage patients with metal-on-metal hip arthroplasty in the same way? An analysis from the International Specialist Centre Collaboration on MOM Hips (ISCCoMH)

    OpenAIRE

    Berber, R.; Skinner, J.; Board, T; KENDOFF D.; Eskelinen, A. (Anu); Kwon, Y.M.; Padgett, D. E.; Hart, A; ISCCoMH

    2016-01-01

    AIMS: There are many guidelines that help direct the management of patients with metal-on-metal (MOM) hip arthroplasties. We have undertaken a study to compare the management of patients with MOM hip arthroplasties in different countries. METHODS: Six international tertiary referral orthopaedic centres were invited to participate by organising a multi-disciplinary team (MDT) meeting, consisting of two or more revision hip arthroplasty surgeons and a musculoskeletal radiologist. A full clinica...

  11. Primary total hip arthroplasty for acetabular fracture

    Institute of Scientific and Technical Information of China (English)

    WANG Zi-ming; SUN Hong-zhen; WANG Ai-min; DU Quan-yin; WU Siyu; ZHAO Yu-feng; TANG Ying

    2006-01-01

    Objective: To explore the operative indications and operative methods of primary total hip arthroplasty for acetabular fracture and to observe the clinical curative effect.Methods: We retrospectively summarized and analyzed the traumatic conditions, fracture types, complications,operative time, operative techniques, and short-term curative effect of 11 patients( 10 males and 1 female, with a mean age of 42. 4 years ) with acetabular fracture who underwent primary total hip arthroplasty.Results: The patients were followed up for 6-45 months ( mean = 28 months). Their average Harris score of postoperative hip joint was 78.Conclusion: Under strict mastery of indications,patients with acetabular fracture may undergo primary total hip arthroplasty, but stable acetabular components should be made.

  12. The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty.

    Science.gov (United States)

    Brokelman, Roy B G; Haverkamp, Daniel; van Loon, Corné; Hol, Annemiek; van Kampen, Albert; Veth, Rene

    2012-06-01

    INTRODUCTION: Patient satisfaction becomes more important in our modern health care system. The assessment of satisfaction is difficult because it is a multifactorial item for which no golden standard exists. One of the potential methods of measuring satisfaction is by using the well-known visual analogue scale (VAS). In this study, we validated VAS for satisfaction. PATIENT AND METHODS: In this prospective study, we studied 147 patients (153 hips). The construct validity was measured using the Spearman correlation test that compares the satisfaction VAS with the Harris hip score, pain VAS at rest and during activity, Oxford hip score, Short Form 36 and Western Ontario McMaster Universities Osteoarthritis Index. The reliability was tested using the intra-class coefficient. RESULTS: The Pearson correlation test showed correlations in the range of 0.40-0.80. The satisfaction VAS had a high correlation between the pain VAS and Oxford hip score, which could mean that pain is one of the most important factors in patient satisfaction. The intra-class coefficient was 0.95. CONCLUSIONS: There is a moderate to mark degree of correlation between the satisfaction VAS and the currently available subjective and objective scoring systems. The intra-class coefficient of 0.95 indicates an excellent test-retest reliability. The VAS satisfaction is a simple instrument to quantify the satisfaction of a patient after total hip arthroplasty. In this study, we showed that the satisfaction VAS has a good validity and reliability.

  13. Low revision rate after total hip arthroplasty in patients with pediatric hip diseases

    DEFF Research Database (Denmark)

    Engesæter, Lars B; Engesæter, Ingvild Ø; Fenstad, Anne Marie

    2012-01-01

    Association (NARA). Cox multiple regression, with adjustment for age, sex, and type of fixation of the prosthesis was used to calculate the survival of the prostheses and the relative revision risks. Results 370,630 primary THAs were reported to these national registers for 1995-2009. Of these, 14,403 THAs (3......). Consequently, an increased risk of revision for hips with a previous pediatric hip disease was seen (risk ratio (RR) 1.4, 95% CI: 1.3-1.5). However, after adjustment for differences in sex and age of the patients, and in fixation of the prostheses, no difference in survival was found (93.6% after pediatric hip...... 0.8, CI: 0.7-1.0). Interpretation After adjustment for differences in age, sex, and type of fixation of the prosthesis, no difference in risk of revision was found for primary THAs performed due to pediatric hip diseases and those performed due to primary OA....

  14. Ultrasound findings in asymptomatic patients with modular metal on metal total hip arthroplasty.

    Science.gov (United States)

    Frisch, Nicholas B; Wessell, Nolan M; Taliaferro, Kevin; Van Holsbeeck, Marnix; Silverton, Craig D

    2017-05-01

    The use of metal-on-metal and modular total hip arthroplasty is associated with potentially serious local and systemic complications. The primary aim of this study was to identify the prevalence of a pseudotumor in asymptomatic patients with a particular metal-on-metal hip prosthesis after a minimum follow-up of 5 years using ultrasound evaluation. A secondary purpose was to identify associations between the presence of pseudotumor and serum metal ion levels following implantation. We prospectively evaluated data collected from 36 asymptomatic patients who underwent implantation of a Profemur Z metal-on-metal total hip arthroplasty from January 2004 to January 2010. Serum metal ion levels were collected in 2012 and 2015. Hip ultrasounds were performed in 2015. Pseudotumors were found in 7/36 patients (19.4%). The average pseudotumor size measured 38.2 cm(3) (range 7.35 cm(3)-130.81 cm(3)). Elevated metal ion levels were found in all patients at all time points. No statistical correlation was found between the presence of pseudotumor and patient age, age of the implant, component design, and any of the serum metal ion levels or ratios. One in every five asymptomatic patients with metal-on-metal implants was found to have a periarticular pseudotumor. There was no dose-dependent relationship found between elevated serum metal ion levels and the development of a pseudotumor. Our findings suggest that in patients with known elevated metal ion levels, continued monitoring of ion levels may not be a reliable predictor of pseudotumor formation, and ultrasound surveillance can and should be routinely used to document the presence and progression of pseudotumor.

  15. Oral ferrous sulfate does not increase preoperative hemoglobin in patients scheduled for hip or knee arthroplasty.

    Science.gov (United States)

    Lachance, Kim; Savoie, Michel; Bernard, Maryse; Rochon, Stéphanie; Fafard, Josée; Robitaille, Robert; Vendittoli, Pascal-André; Lévesque, Sylvie; de Denus, Simon

    2011-06-01

    Low hemoglobin (Hb) concentrations before lower limb joint replacement are associated with the need for blood transfusions and increased mortality. To optimize preoperative Hb, blood conservation protocols often recommend oral iron supplements, even in nonanemic patients. To investigate the impact of ferrous sulfate on the change in Hb prior to hip or knee arthroplasty and evaluate the effect of oral iron on hematocrit, mean corpuscular volume (MCV), ferritin, and transferrin saturation, as well as its tolerability and treatment adherence. We conducted a prospective, observational cohort study of adults with Hb concentrations between 10 and 15 g/dL who received iron supplementation prior to hip or knee arthroplasty. Systemic inflammatory diseases, vitamin B(12) or folate deficiency, and current use of iron supplements, intravenous iron, or erythropoietin were exclusion criteria. All participants were prescribed ferrous sulfate 300 mg 3 times daily for a minimum of 3 weeks. Complete blood cell counts and iron studies were performed before therapy and surgery. Eighty-seven patients with a mean (SD) Hb of 13.47 (0.84) g/dL were included in the study. Preoperative Hb decreased after treatment with iron (-0.14 [0.53] g/dL, p = 0.015). Hematocrit also declined (-0.6% [1.8%], p = 0.002), whereas ferritin increased (25.8 [38.6] ng/mL, p ferrous sulfate supplementation is not an effective method to increase preoperative Hb in patients scheduled for hip or knee arthroplasty, and its use is associated with adverse effects.

  16. Patient-reported outcome of hip resurfacing arthroplasty and standard total hip replacement after short-term follow-up

    DEFF Research Database (Denmark)

    Nissen, Nina; Douw, Karla; Overgaard, Søren

    2011-01-01

    The purpose of this study was to investigate patientreported outcome in terms of satisfaction in two study groups that had undergone hip resurfacing arthro-plasty (HRA) or total hip replacement (THR). The procedure consists of placing a hollow, mushroom-shaped metal cap over the femoral head while...

  17. Patient-reported outcome of hip resurfacing arthroplasty and standard total hip replacement after short-term follow-up

    DEFF Research Database (Denmark)

    Nissen, Tina Koerner; Douw, Karla; Overgaard, Søren

    2011-01-01

    The purpose of this study was to investigate patientreported outcome in terms of satisfaction in two study groups that had undergone hip resurfacing arthro-plasty (HRA) or total hip replacement (THR). The procedure consists of placing a hollow, mushroom-shaped metal cap over the femoral head while...

  18. Effect of hydroxyapatite coating on risk of revision after primary total hip arthroplasty in younger patients: findings from the Danish Hip Arthroplasty Registry

    DEFF Research Database (Denmark)

    Paulsen, Aksel; Pedersen, Alma B; Johnsen, Søren P

    2007-01-01

    Arthroplasty Registry (DHR), we identified patients less than 70 years old who had undergone uncemented primary THA during 1997-2005. 4,125 HA-coated and 7,737 non-HA-coated cups and 3,158 HA-coated and 4,749 non-HA-coated stems were available for analysis. The mean follow-up time was 3.4 years for cups and 3.......61-1.1) for HA-coated cups and stems, respectively. INTERPRETATION: In this medium-term follow-up study, the use of HA-coated implants was not associated with any clearly reduced overall risk of revision compared to non-HA-coated implants.......BACKGROUND: The effect of hydroxyapatite (HA) on implant survival in the medium and long term is uncertain. We studied the effect of HA coating of uncemented implants on the risk of cup and stem revision in primary total hip arthroplasty (THA). PATIENTS AND METHODS: Using the Danish Hip...

  19. Economic impact of tranexamic acid in healthy patients undergoing primary total hip and knee arthroplasty.

    Science.gov (United States)

    Gillette, Blake P; Maradit Kremers, Hilal; Duncan, Christopher M; Smith, Hugh M; Trousdale, Robert T; Pagnano, Mark W; Sierra, Rafael J

    2013-09-01

    Tranexamic acid (TA) has been shown to reduce perioperative blood loss and blood transfusion. While concern remains about the cost of antifibrinolytic medication, we hypothesized that routine use of tranexamic acid would result in lower direct hospital total cost by decreasing costs associated with blood transfusion, laboratory testing, and room & board. Patients with an American Society of Anesthesiologists (ASA) class II or less undergoing primary total hip or knee arthroplasty at a single institution during 2007-2008 were retrospectively reviewed. The estimated mean direct hospital total cost, operating room, blood/lab, room & board, and pharmacy costs were compared between patients who did and did not receive TA. The study population included 1018 patients, and 580 patients received TA. The mean direct total cost of hospitalization with and without TA was $15,099 and $15,978 (P<.0002) respectively, a difference of $879. The only increased cost associated with TA was the pharmacy cost which was $921 versus $781 (P<.0001). The routine use of tranexamic acid TA was associated with lower mean direct hospital total costs after primary total hip and knee arthroplasty as the increase in pharmacy costs was more than offset by cost savings in other categories.

  20. Incidence of delirium in postoperative patients treated with total knee and hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Felipe de Santana Bosmak

    Full Text Available Summary Introduction: Delirium is a common disorder that can potentiate mortality and comorbidity rates of patients hospitalized in intensive care units. Patients undergoing major orthopedic surgeries, such as knee and hip arthroplasty, are particularly vulnerable as they often have multiple risk factors for this disorder. Method: Descriptive study of the incidence of delirium in patients treated with total knee and hip arthroplasty, given the advanced age and comorbidities in this population. We evaluated the medical records of patients who had previously undergone the designated surgeries for identification of postoperative delirium. Results: We observed in this study an incidence of 8.92% of delirium, mostly affecting females with a mean age of 73 years and hypertension. Conclusion: The incidence of delirium in our study is similar to that observed in the general population, according to the literature. We found no correlation with sleep disorders, smoking or diabetes mellitus in this study, even though the importance of these factors for the onset of delirium is well-established in the literature.

  1. Detecting cause of dislocation after total hip arthroplasty by patient-specific four-dimensional motion analysis.

    Science.gov (United States)

    Miki, Hidenobu; Sugano, Nobuhiko; Yonenobu, Kazuo; Tsuda, Kosuke; Hattori, Maki; Suzuki, Naoki

    2013-02-01

    Dislocation is a major complication after total hip arthroplasty. Prosthesis impingement is considered to be an important cause of dislocation because impingement marks are more frequently found on retrieved cups or liners in patients who have undergone revision surgery because of dislocation (80%-94%) than in those who have undergone reoperation for other reasons (51%-56%). However, it remains a question whether impingement marks are the cause of dislocation or are instead its result. To clarify the issue, it is necessary to confirm noninvasively whether the point of impingement matches the patient's hip position when dislocation occurs. Using four-dimensional patient-specific analysis, we recorded prosthesis impingement in 10 hips with instability after primary total hip arthroplasty when the patients reproduced the dislocation-causing motion. We found prosthesis impingement to be related to at least instability in 6 of 10 hips with dislocation after primary total hip arthroplasty and in 4 of 4 hips that underwent revision surgery for recurrent dislocation. All impingements occurred between the anterior wall of the liner and the stem neck in posterior dislocation and between the posterior wall of the liner and the stem neck in anterior dislocation. Revision surgery in 1 of those 4 hips revealed 2 impingement marks on the retrieved liner that closely matched the prosthesis impingement point and the dislocation pathway of the metal head on the liner that were detected earlier during motion analysis. Prosthesis impingement is an important factor in dislocation after total hip arthroplasty. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Ultrasound-Guided Suprainguinal Fascia Iliaca Technique Provides Benefit as an Analgesic Adjunct for Patients Undergoing Total Hip Arthroplasty.

    Science.gov (United States)

    Bullock, W Michael; Yalamuri, Suraj M; Gregory, Stephen H; Auyong, David B; Grant, Stuart A

    2017-02-01

    Analgesia after total hip arthroplasty is often accomplished by the fascia iliaca compartment block, traditionally performed below the inguinal ligament, to anesthetize both femoral and lateral femoral cutaneous nerves. The course of the lateral femoral cutaneous nerve below the inguinal ligament is variable as opposed to consistent above the inguinal ligament in the pelvis. In this case series including 5 patients, we demonstrate that an ultrasound-guided suprainguinal fascia iliaca approach would consistently anesthetize the lateral femoral cutaneous nerve along with anterior cutaneous femoral nerve branches and provide cutaneous analgesia after total hip arthroplasty, as shown by decreased opioid consumption.

  3. Patient-reported outcomes for total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Collins, Natalie J; Roos, Ewa M.

    2012-01-01

    , and high personal and financial cost associated with THA and TKA, patient-reported outcomes are required to ensure optimal selection of patients, and that postoperative outcomes outweigh the burden associated with surgical procedures. It is clear from the information presented that clinicians need...... to consider a number of factors when selecting a "good" patientreported outcome for use in their TJA patients. Not only does the instrument need to measure dimensions appropriate for THA and TKA patients, but it also needs to have minimal administrative burden, accessibility to a variety of clinicians...... and patients, reliability, validity, and responsiveness to change. Furthermore, knowledge regarding the minimal score that patients deem to be meaningful is useful in interpreting whether a patient has experienced real improvement in their condition after surgery. It is clear that further studies are required...

  4. Preoperative ambulatory measurement of asymmetric leg loading during sit-to-stand in hip arthroplasty patients.

    Science.gov (United States)

    Martínez-Ramírez, Alicia; Weenk, Dirk; Lecumberri, Pablo; Verdonschot, Nico; Pakvis, Dean; Veltink, Peter H

    2014-05-01

    Total hip arthroplasty (TGA) is a successful surgical procedure to treat patients with hip osteoarthritis. Clinicians use different questionnaires to evaluate these patients. Gait velocity and these questionnaires; usually show significant improvement after TGA . This clinical evaluation does, however, not provide objective, quantifiable information about the movement patterns underlying the functional capacity, which is clinically important and can currently only be obtained in a gait laboratory. There is a need to improve patient instructions and to quantify the rehabilitation process. The sit-to-stand (STS) movement is an objective performance-based task, whose assessment is related with the evaluation of functional recovery. Twenty two patients with hip osteoarthritis participated in this study. For each patient, validated questionnaires were administered and gait velocity was measured. Time, ground reaction forces, and lower limb asymmetry parameters were calculated using the instrumented force shoes (IFS) during STS movement with and without armrest. Significant inter-limb asymmetry was observed. No correlation was found between any parameter and gait velocity and questionnaires outcomes. Significant differences in time and force parameters between with/without armrest were found. Concluding, inter-limb asymmetry can be evaluated with the IFS supplying important additional information not represented by gait velocity and questionnaires usually used.

  5. Nuances of preoperative planning of total hip arthroplasty in patients with hip dysplasia

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2015-01-01

    Full Text Available Purpose of the study - to evaluate in different groups of patients variability of anatomical changes that may affect the difference in the length of the lower extremities and affect on the results of the preoperative planning. Material and methods. As study material we used long film X-ays of 142 patients. A main group comprised 69 patients with varying severity of hip dysplasia. Control group consisted of 73 patients without hip pathology. All patients were performed long film X-rays, and measurements of relative and absolute lengths of the lower limbs, followed by analysis of the data. Results. Analysis of the measurements showed that none of the patients had absolutely equal length of the lower limbs, even in the control group in 56.2% of the observations noted the absolute difference of the lower extremities length more than 5 mm, and in 9.6% of patients - from 20 to 35 mm. In assessing the difference of the lower extremities length on AP pelvic view in the main group only one patient of 69 had the same length of the legs, and in 61 cases the difference was more than 5 mm, that it was clinically significant. Of practical interest is the fact that in the main group shortening of the operated limb was observed in 51 of 69 patients in AP views of the pelvis, but the results of measurements of the anatomical length of limbs long film X-rays compared with measurements of the relative shortening on the pelvis AP views showed that clinically significant difference exceeding 5 mm between measurements observed in 68.1% of cases. The greatest difference between the measurements of the limbs length on the pelvis AP views and long film X-rays observed in patients with unilateral hip dislocation and averaged 17.0 mm. Conclusion. Performing preoperative planning in patients with dysplasia only on pelvis AP views not allow properly compensate the difference of the lower extremities lengths, which may adversely affect the functional results of surgery and

  6. Physical and rehabilitation medicine (PRM) care pathways: "patients after total hip arthroplasty".

    Science.gov (United States)

    Ribinik, P; Le Moine, F; de Korvin, G; Coudeyre, E; Genty, M; Rannou, F; Yelnik, A; Calmels, P

    2012-11-01

    This document is part of a series of documents designed by the French Physical and Rehabilitation Medicine Society (SOFMER) and the French Federation of PRM (FEDMER). These documents describe the needs for or a specific type of patients; PRM care objectives, human and material resources to be implemented, chronology as well as expected outcomes. "Care pathways in PRM" is a short document designed to enable the reader (physicians, decision-maker, administrator, lawyer or finance manager) to quickly apprehend the needs of these patients and the available therapeutic care structures for proper organization and pricing of these activities. Patients after total hip arthroplasty are classified into three care sequences and two clinical categories, each one being treated with the same six parameters according to the International Classification of Functioning, Disability and Health (WHO), while taking into account personal and environmental factors that could influence the needs of these patients.

  7. Designing a Safety Reporting Smartphone Application to Improve Patient Safety After Total Hip Arthroplasty.

    Science.gov (United States)

    Krumsvik, Ole Andreas; Babic, Ankica

    2017-01-01

    This paper presents a safety reporting smartphone application which is expected to reduce the occurrence of postoperative adverse events after total hip arthroplasty (THA). A user-centered design approach was utilized to facilitate optimal user experience. Two main implemented functionalities capture patient pain levels and well-being, the two dimensions of patient status that are intuitive and commonly checked. For these and other functionalities, mobile technology could enable timely safety reporting and collection of patient data out of a hospital setting. The HCI expert, and healthcare professionals from the Haukeland University Hospital in Bergen have assessed the design with respect to the interaction flow, information content, and self-reporting functionalities. They have found it to be practical, intuitive, sufficient and simple for users. Patient self-reporting could help recognizing safety issues and adverse events.

  8. Physical Activity Behavior of Patients 1 Year After Primary Total Hip Arthroplasty : A Prospective Multicenter Cohort Study

    NARCIS (Netherlands)

    Wagenmakers, Robert; Stevens, Martin; Groothoff, Johan W.; Zijlstra, Wiebren; Bulstra, Sjoerd K.; van Beveren, Jan; van Raaij, Jos J. A. M.; van den Akker-Scheek, Inge

    2011-01-01

    Background. Besides the important beneficial effects of regular physical activity on general health, some of the musculoskeletal effects of physical activity are of particular interest for older adults after total hip arthroplasty (THA). However, research on physical activity behavior of patients af

  9. [Pelvic lymphadenitis after total hip arthroplasty : Mimicking of lymph node metastases in a patient with prostate cancer].

    Science.gov (United States)

    Sevinc, S; Westhoff, C C; Schrader, A J; Olbert, P J; Hofmann, R; Hegele, A

    2010-08-01

    This report describes the case of a 65-year-old patient who underwent radical prostatectomy in our department. Intraoperatively we detected suspicious lymph nodes on the left side. The histopathological examination revealed histiocytosis and foreign body giant cells but no sign of tumor. The enlarged lymph nodes were ascribed to an ipsilateral total hip arthroplasty performed 14 years previously because of progressive coxarthrosis. Lymphadenitis after total hip arthroplasty is frequently observed. Histopathologically and with the use of polarized light microscopy, histiocytosis and wear particles such as titanium, polyethylene, and polyethylene-methylacrylate may be detected. When operating on patients with arthroplasty of a lower limb, particularly those with a total endoprosthesis, the surgeon should bear in mind that changes in lymph node consistency and size do not necessarily indicate tumor involvement or metastases.

  10. Preoperative pain level and patient expectation predict hospital length of stay after total hip arthroplasty.

    Science.gov (United States)

    Halawi, Mohamad J; Vovos, Tyler J; Green, Cindy L; Wellman, Samuel S; Attarian, David E; Bolognesi, Michael P

    2015-04-01

    The purpose of this study was to identify preoperative predictors of length of stay after primary total hip arthroplasty in a patient population reflecting current trends toward shorter hospitalization and using readily obtainable factors that do not require scoring systems. A retrospective review of 112 consecutive patients was performed. High preoperative pain level and patient expectation of discharge to extended care facilities (ECFs) were the only significant multivariable predictors of hospitalization extending beyond 2 days (P=0.001 and Pexpectation remained significant after adjusting for Medicare's 3-day requirement for discharge to ECFs (P<0.001). The study was adequately powered to analyze the variables in the multivariable logistic regression model, which had a concordance index of 0.857.

  11. Total Hip Arthroplasty after Treatment of an Atypical Subtrochanteric Femoral Fracture in a Patient with Pycnodysostosis

    Directory of Open Access Journals (Sweden)

    Takahito Yuasa

    2015-01-01

    Full Text Available The authors describe the case of a 51-year-old woman with an osteonecrosis of her right femoral head after treatment of an atypical subtrochanteric fracture caused by pycnodysostosis. She had this fracture after a low-trauma fall. She was of short stature with typical facial features, short stubby hands, and radiological features including open cranial sutures, obtuse mandible, and generalized skeletal sclerosis. The majority of cases of atypical subtrochanteric fractures are associated with long-term use of bisphosphonates; some occur in bisphosphonate-free patients. We report a rare case of total hip arthroplasty (THA in a patient with pycnodysostosis who developed an osteonecrosis of the femoral head after treatment of an atypical subtrochanteric femoral fracture. We performed cementless THA in combination with a plate and cables. Cementless THA is a potential intervention in a patient with pycnodysostosis; although the bone quality may have been sclerotic, healing is not a problem in this condition.

  12. Total hip arthroplasty: leg length inequality impairs functional outcomes and patient satisfaction

    Directory of Open Access Journals (Sweden)

    Röder Christoph

    2012-06-01

    Full Text Available Abstract Background Leg length inequality (LLI was identified as a problem of total hip arthroplasty soon after its introduction. Leg lengthening is the most common form of LLI. Possible consequences are limping, neuronal dysfunction and aseptic component loosening. LLI can result in an increased strain both on the contralateral hip joint and on the abductor muscles. We assessed the influence of leg lengthening and shortening on walking capacity, hip pain, limping and patient satisfaction at 2-year follow-up. Methods 478 cases with postoperative lengthening and 275 with shortening were identified, and matched with three controls each. Rigorous adjustment for potential differences in baseline patient characteristics was performed by propensity-score matching of covariates. The arbitrarily defined desired outcomes were a walking capacity >60 minutes, no hip pain, no limping, and excellent patient satisfaction. Differences in not achieving the desired outcomes between the groups were expressed as odds ratios. Results In the lengthened case group, the odds ratio for not being able to walk for an hour was 1.70 (95% CI 1.28-2.26 for cases compared to controls, and the odds ratio for having hip pain at follow-up was 1.13 (95% CI 0.78-1.64. The odds ratio for limping was 2.08 (95% CI 1.55-2.80. The odds ratio for not achieving excellent patient satisfaction was 1.67 (95% CI 1.23-2.28. In the shortening case group, the odds ratio for not being able to walk for an hour was 1.23 (95% CI 0.84-1.81, and the odds ratio for having hip pain at follow-up was 1.60 (95% CI 1.05-2.44. The odds ratio for limping for cases was 2.61 (95% CI 1.78-3.21. The odds ratio for not achieving excellent patient satisfaction was 2.15 (95% CI 1.44-3.21. Conclusions Walking capacity, limping and patient satisfaction were all significantly associated with leg lengthening, whereas pain alleviation was not. In contrast, hip pain, limping and patient satisfaction were all

  13. Prescription trajectories and effect of total hip arthroplasty on the use of analgesics, hypnotics, antidepressants, and anxiolytics: results from a population of total hip arthroplasty patients.

    Science.gov (United States)

    Blågestad, Tone; Nordhus, Inger H; Grønli, Janne; Engesæter, Lars B; Ruths, Sabine; Ranhoff, Anette H; Bjorvatn, Bjørn; Pallesen, Ståle

    2016-03-01

    Total hip arthroplasty (THA) has been shown to reduce pain and improve function. In addition, it is suggested that THA improves sleep and alleviates symptoms of anxiety and depression. Patients with chronic pain are frequent users of analgesic and psychotropic drugs and thereby risk adverse drug events. The impact of THA on such drug use has not been thoroughly investigated. Based on merged data from the Norwegian Prescription Database and the Norwegian Arthroplasty Register, this study sought to investigate redeemed medications in a complete population (N = 39,688) undergoing THA in 2005 to 2011. User rates and redeemed drug volume of analgesics (nonsteroid anti-inflammatory drugs (NSAIDs), opioids, and nonopioids) and psychotropics (hypnotics, anxiolytics, and antidepressants) were calculated for 4 quarters before and 4 quarters after surgery. We analysed preoperative prescription trends (Q1 vs Q4), postoperative prescription (Q4 vs Q5), and long-term effect of surgery (Q4 vs Q8). Before surgery, use of all drug groups increased from Q1 to Q4. Use of opioids, nonopioids, and hypnotics dramatically increased from Q4 to Q5. Long-term (Q4 vs Q8) surgery reduced prescriptions of analgesics, hypnotics, and anxiolytics, but not antidepressants. Overall, the present results extend the positive effects of THA to include reduced reliance on medication to alleviate symptoms.

  14. Role of patient characteristics for fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jørgensen, C C; Kehlet, H; Søballe, Kjeld;

    2013-01-01

    with early mobilization and an LOS aim of 2-4 days remains unanswered.MethodA prospective study on patient characteristics and comorbidity in consecutive unselected patients undergoing fast-track THA and TKA was cross-referenced with the Danish National Health Registry and medical charts allowing complete 90......BACKGROUND: /st>Patient age and comorbidity have been found to increase the length of hospital stay (LOS), readmissions, and mortality after surgery, including in elective primary total hip arthroplasty (THA) and total knee arthroplasty (TKA). Whether the same applies in fast-track THA and TKA...... days follow-up. RESULTS: /st>A total of 3112 THA/TKAs were performed in 3020 patients. The mean age was 67 (range 18-97) years. The median LOS was 3 (inter-quartile range: 1) and the mean 3.0 days (range 1-34), with 91% having LOS ≤4 days. Age 76-80 [odds ratio (OR): 1.57; 95% confidence interval (CI...

  15. Outcome in Patients with High Body Mass Index following Primary Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Zuned Hakim

    2015-01-01

    Full Text Available Obesity is becoming a critical problem in the developed world and is associated with an increased incidence of osteoarthritis of the hip. The Oxford Hip Score was used to determine if Body Mass Index (BMI is an independent factor in determining patient outcome following primary total hip arthroplasty (THA. Using data from 353 operations we found that patients with BMI ≥ 30 had an absolute score that was lower preoperatively and postoperatively compared to those with a BMI < 30. There was no difference in pre- and postoperative point score change within each group; Kendall’s rank correlation was 0.00047 (95% CI, −0.073 to 0.074 (p=0.99 and demonstrated no trend. There was no statistically significant difference in change between those with BMI ≥ 30 and < 30 (p=0.65. We suggest that those with a higher BMI be considered for THA as they can expect the same degree of improvement as those with a lower BMI. Given the on-going increase in obesity these findings could be significant for the future of THA.

  16. A comparison between patient recall and concurrent measurement of preoperative quality of life outcome in total hip arthroplasty.

    Science.gov (United States)

    Howell, Jonathan; Xu, Min; Duncan, Clive P; Masri, Bassam A; Garbuz, Donald S

    2008-09-01

    The objective is to evaluate the reliability of patients' recall of preoperative pain and function during the immediate postoperation period after total hip arthroplasty. A prospective cohort of 104 patients completed a survey about their quality of life before operation, and recalled preoperative status at 3 days, 6 weeks, and 12 weeks after operation. Quality of life was measured by the Western Ontario and McMaster University Osteoarthritis Index, the Oxford-12 hip score, and the 12-item Short-Form score. The intraclass correlation coefficient and Spearman correlation coefficient were used to compare preoperative quality of life scores to the scores recalled. The reliability of recall remained high up to 3 months postoperation. Patients are able to accurately recall their preoperative function for up to 3 months after total hip arthroplasty.

  17. Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: a diagnostic cohort study of 48 patients

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Hao; Yang, Dejin; Guo, Shengjie; Tang, Jing; Liu, Jian; Wang, Dacheng; Zhou, Yixin [Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Department of Orthopaedic Surgery, Beijing (China)

    2016-11-15

    For postoperative imaging assessment of cementless hip arthroplasty, radiography and computed tomography (CT) were restricted by overlapping structures and metal artifacts, respectively. A new tomosynthesis with metal artifact reduction (TMAR) is introduced by using metal extraction and ordered subset-expectation maximization (OS-EM) reconstruction. This study investigated the effectiveness of TMAR in assessing fixation stability of cementless hip arthroplasty components. We prospectively included 48 consecutive patients scheduled for revision hip arthroplasty in our hospital, with 41 femoral and 35 acetabular cementless components available for evaluation. All patients took the three examinations of radiography, CT, and TMAR preoperatively, with intraoperative mechanical tests, and absence or presence of osteointegration on retrieved prosthesis as reference standards. Three senior surgeons and four junior surgeons evaluated these images independently with uniform criteria. For TMAR, 82 % diagnoses on the femoral side and 84 % diagnoses on the acetabular side were accurate. The corresponding values were 44 and 67 % for radiography, and 39 % and 74 % for CT. Senior surgeons had significantly higher accuracy than junior surgeons by radiography (p < 0.05), but not by TMAR or CT. By minimizing metal artifacts in the bone-implant interface and clearly depicting peri-implant trabecular structures, the TMAR technique improved the diagnostic accuracy of assessing fixation stability of cementless hip arthroplasty, and shortened the learning curve of less experienced surgeons. Level II, diagnostic cohort study. (orig.)

  18. Acetabular Dysplasia in Middle-Aged Patients: Periacetabular Osteotomy or Total Hip Arthroplasty?

    Science.gov (United States)

    Kalore, Niraj V; Cheppalli, Suresh P R; Daner, William E; Jiranek, William A

    2016-09-01

    Treatment of middle-aged patients with acetabular dysplasia is challenging because of mild osteoarthritis, long life span, high activity level, and sports participation. Both periacetabular osteotomy (PAO) and total hip arthroplasty (THA) provide pain relief, improve function, and can last over 2 decades. We compare the 2 procedures for functional outcome (including sports participation), pain relief, and morbidity. We compared patients in the 30-50 years age group with symptomatic acetabular dysplasia who underwent PAO (n = 14) or THA (n = 14) with minimum 4-year follow-up. We compared postoperative activity (modified Harris Hip Score, high activity arthroplasty score, and modified Merle d'Aubigné-Postel Score) and sports participation (Tegner and University of California Los Angeles activity scores) in the 2 groups. Morbidity was compared by durations of postoperative pain >4/10, narcotic use, use of gait aids, and time to return to normal activities. Sports participation and function scores improved after surgery in both groups without significant intergroup difference at minimum 4-year follow-up. Patients with PAO had longer duration of postoperative pain (P = .01) and used gait aids longer (P = .04) than patients with THA. There were 3 minor reoperations in the PAO group and none in the THA group. PAO and THA both produce comparable improvement in sports participation and function. PAO was associated with longer durations of pain and use of gait aids. These findings may be important in the decision-making process in middle-aged patients with symptomatic acetabular dysplasia. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Total Hip Arthroplasty in Patients of Post Polio Residual Paralysis: A Retrospective Case Series.

    Science.gov (United States)

    Sobrón, Francisco Borja; Martínez-Ayora, Álvaro; Cuervas-Mons, Manuel; Quevedo, Tania; Laguna, Rafael; Vaquero, Javier

    2017-01-01

    Poliomyelitis is a viral, nervous system disease that affects both the upper and the lower extremities. The treatment of severe coxarthrosis in these patients with total hip arthroplasty (THA) has been widely questioned because of the high risk of subsequent complications. The aim of the present study was to describe both radiological and medium term clinical results in a series of patients with post polio residual paralysis that underwent THA. We report a retrospective review of a series of 5 five patients diagnosed with severe coxarthrosis secondary to post polio residual paralysis who were operated between 2008 and 2012. Uncemented THA was performed in all cases by the same surgeon. Clinical evaluation was carried out using the Harris Hip Score (HHS) at the preoperative visit, at 6 months, and annually after surgery. The median age was 47 years, and the median followup was 55 months (interquartile range P25-P75: range 31-72 months). According to the HHS, a significant clinical improvement was observed in all patients with a median score of 81 points (interquartile range P25-P75: range 74-89) at 1 year of followup. A case of relapsing dislocation that required revision surgery of the implant was recorded. No cases of component loosening were found. THA surgery in patients with post polio residual paralysis is a complex procedure with a significant complication rate, but a predictable clinical improvement may encourage surgeons to perform in patients with severe coxarthrosis and moderate functional expectations.

  20. CURBSIDE CONSULTATION IN HIP ARTHROPLASTY

    Directory of Open Access Journals (Sweden)

    Scott M. Sporer

    2009-03-01

    Full Text Available DESCRIPTION A user friendly reference for decision making in hip arthroplasty designed in a question formed clinical problem scenarios and answers format .The articles composed of the answers, containing current concepts and preferences of experts in primary and revision hip surgery are enhanced by several images, diagrams and references and written in the form of a curbside consultation by Scott M. Sporer, MD. and his collaborators. PURPOSE By this practical reference of hip arthroplasty, Scott M. Sporer, MD. and the contributors have aimed providing the reader practical and clinically relevant information, evidence-based advices, their preferences and opinions containing current concepts for difficult and controversial clinical situations in total hip replacement surgery which are often not addressed clearly in traditional references. FEATURES The book is composed of 9 sections and 49 articles each written by a different expert designed in a question and answers format including several images and diagrams and also essential references at the end of each article. In the first section preoperative questions is subjected. Second section is about preoperative acetabulum questions. Third section is about preoperative femur questions. Fourth section is about intraoperative questions. Intraoperative acetabulum question is subjected in the fifth section and the intraoperative femur questions in the sixth section. The seventh section is about postoperative questions. Eighth and ninth sections are about general questions about failure and failure of acetabulum in turn. AUDIENCE Mainly practicing orthopedic surgeons, fellows and residents who are interested in hip arthroplasty have been targeted but several carefully designed scenarios of controversial and difficult situations surrounding total hip replacement surgery and the current information will also be welcomed by experienced clinicians practicing in hip arthroplasty. ASSESSMENT Scott M. Sporer

  1. Total hip arthroplasty following failed fixation of proximal hip fractures

    Directory of Open Access Journals (Sweden)

    Srivastav Shekhar

    2008-01-01

    Full Text Available Background: Most proximal femoral fractures are successfully treated with internal fixation but a failed surgery can be very distressing for the patient due to pain and disability. For the treating surgeon it can be a challenge to perform salvage operations. The purpose of this study was to evaluate the short-term functional outcome and complications of total hip arthroplasty (THA following failed fixation of proximal hip fracture. Materials and Methods: In a retrospective study, 21 hips in 20 patients (13 females and seven males with complications of operated hip fractures as indicated by either established nonunion or fracture collapse with hardware failure were analysed. Mean age of the patients was 62 years (range 38 years to 85 years. Nine patients were treated for femoral neck fracture, 10 for intertrochanteric (I/T fracture and two for subtrochanteric (S/T fracture of the hip. Uncemented THA was done in 11 cases, cemented THA in eight hip joints and hybrid THA in two patients. Results: The average duration of follow-up was four years (2-13 years. The mean duration of surgery was 125 min and blood loss was 1300 ml. There were three dislocations postoperatively. Two were managed conservatively and one was operated. There was one superficial infection and one deep infection. Only one patient required a walker while four required walking stick for ambulation. The mean Harris Hip score increased from 32 preoperatively to 79 postoperatively at one year interval. Conclusion: Total hip arthroplasty is an effective salvage procedure after failed osteosynthesis of hip fractures. Most patients have good pain relief and functional improvements inspite of technical difficulties and high complication rates than primary arthroplasty.

  2. Th1 type lymphocyte reactivity to metals in patients with total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Finnegan Alison

    2008-02-01

    Full Text Available Abstract Background All prostheses with metallic components release metal debris that can potentially activate the immune system. However, implant-related metal hyper-reactivity has not been well characterized. In this study, we hypothesized that adaptive immunity reaction(s, particularly T-helper type 1 (Th1 responses, will be dominant in any metal-reactivity responses of patients with total joint replacements (TJAs. We tested this hypothesis by evaluating lymphocyte reactivity to metal "ions" in subjects with and without total hip replacements, using proliferation assays and cytokine analysis. Methods Lymphocytes from young healthy individuals without an implant or a history of metal allergy (Group 1: n = 8 were used to assess lymphocyte responses to metal challenge agents. In addition, individuals (Group 2: n = 15 with well functioning total hip arthroplasties (average Harris Hip Score = 91, average time in-situ 158 months were studied. Age matched controls with no implants were also used for comparison (Group 3, n = 8, 4 male, 4 female average age 70, range 49–80. Group 1 subjects' lymphocyte proliferation response to Aluminum+3, Cobalt+2, Chromium+3, Copper+2, Iron+3, Molybdenum+5, Manganeese+2, Nickel+2, Vanadium+3 and Sodium+2 chloride solutions at a variety of concentrations (0.0, 0.05, 0.1, 0.5, 1.0 and 10.0 mM was studied to establish toxicity thresholds. Mononuclear cells from Group 2 and 3 subjects were challenged with 0.1 mM CrCl3, 0.1 mM NiCl2, 0.1 mM CoCl2 and approx. 0.001 mM titanium and the reactions measured with proliferation assays and cytokine analysis to determine T-cell subtype prominence. Results Primary lymphocytes from patients with well functioning total hip replacements demonstrated a higher incidence and greater magnitude of reactivity to chromium than young healthy controls (p 2 fold stimulation index response, p 10 mM. The differential secretion of signature T-cell subsets' cytokines (Th1 and Th2 lymphocytes

  3. Deep vein thrombosis after total hip and knee arthroplasty in Indian patients

    OpenAIRE

    Jain, V.; Dhaon, B; Jaiswal, A.; Nigam, V; Singla, J

    2004-01-01

    Background: Deep vein thrombosis (DVT) is one of the most common complications of total hip (THA) and total knee arthroplasty (TKA). Though the reported incidence of DVT is very high, that of proximal DVT is low and that of fatal thromboembolism is very low. Hence the issue of prophylaxis for DVT remains controversial.

  4. Total hip arthroplasty in an outpatient setting in 27 selected patients.

    Science.gov (United States)

    Hartog, Yvon M den; Mathijssen, Nina M C; Vehmeijer, Stephan B W

    2015-01-01

    As a result of introduction of a fast-track program, length of hospital stay after total hip arthroplasty (THA) decreased in our hospital. We therefore wondered whether THA in an outpatient setting would be feasible. We report our experience with THA in an outpatient setting. In this prospective cohort study, we included 27 patients who were selected to receive primary THA in an outpatient setting between April and July 2014. Different patient-reported outcome measures (PROMs) were recorded preoperatively and at 6 weeks and 3 months postoperatively. Furthermore, anchor questions on how patients functioned in daily living were scored at 6 weeks and 3 months postoperatively. 3 of the 27 patients did not go home on the day of surgery because of nausea and/or dizziness. The remaining 24 patients all went home on the day of surgery. PROMs improved substantially in these patients. Moreover, anchor questions on how patients functioned in their daily living indicated that the patients were satisfied with the postoperative results. 1 re-admission occurred at 11 days after surgery because of seroma formation. There were no other complications or reoperations. At our hospital, with a fast-track protocol, outpatient THA was found to be feasible in selected patients with satisfying results up to 3 months postoperatively, without any outpatient procedure-specific complications or re-admissions.

  5. Detection of total hip arthroplasties at airport security checkpoints - how do updated security measures affect patients?

    Science.gov (United States)

    Issa, Kimona; Pierce, Todd P; Gwam, Chukwuweieke; Festa, Anthony; Scillia, Anthony J; Mont, Michael A

    2017-09-05

    There have been historical reports on the experiences of patients with total hip arthroplasty (THA) passing through standard metal detectors at airports. The purpose of this study was to analyse those who had recently passed through airport security and the incidence of: (i) triggering of the alarm; (ii) extra security searches; and (iii) perceived inconvenience. A questionnaire was given to 125 patients with a THA during a follow-up appointment. Those who had passed through airport security after January 2014 met inclusion criteria. A survey was administered that addressed the number of encounters with airport security, frequency of metal detector activation, additional screening procedures utilised, whether security officials required prosthesis documentation, and perceived inconvenience. 51 patients met inclusion criteria. 10 patients (20%) reported triggered security scanners. 4 of the 10 patients stated they had surgical hardware elsewhere in the body. 13 of the 51 patients (25%) believed that having their THA increased the inconvenience of traveling. This is different from the historical cohort with standard metal detectors which patients reported a greater incidence of alarm triggering (n = 120 of 143; p = 0.0001) and perceived inconvenience (n = 99 of 143; p = 0.0001). The percentage of patients who have THA triggering security alarms has decreased. Furthermore, the number of patients who feel that their prosthesis caused traveling inconvenience has decreased. We feel that this decrease in alarms triggered and improved perceptions about inconvenience are related to the increased usage of new technology.

  6. The Self-Administered Patient Satisfaction Scale for Primary Hip and Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    N. Mahomed

    2011-01-01

    Full Text Available Introduction. The objective of this study was to develop a short self-report questionnaire for evaluating patient satisfaction with the outcome of hip and knee replacement surgery. Methods. This scale consists of four items focusing on satisfaction with the extent of pain relief, improvement in ability to perform home or yard work, ability to perform recreational activities, and overall satisfaction with joint replacement. This instrument does not measure satisfaction with process of care. The responses are scored on a Likert scale, with the total score ranging from 25 to 100 per question. The instrument was tested on 1700 patients undergoing primary total hip and total knee replacement surgery, evaluated preoperatively, at 12 weeks, and one year postoperatively. Psychometric testing included internal consistency, measured with Cronbach's alpha, and convergent validity, measured by correlation with changes in measures of health status between the preoperative, 12-week, and one-year evaluations. Results. The internal consistency (reliability of the scale, measured by the Cronbach's alpha, ranged from 0.86 to 0.92. The scale demonstrated substantial ceiling effects at 1 year. The scale scores correlated modestly with the absolute SF-36 PCS and WOMAC scores (ρ=0.56–0.63 and also with the WOMAC change scores (ρ=0.38–0.46 at both 12-week and 1-year followups. Conclusions. This instrument is valid and reliable for measuring patient satisfaction following primary hip and knee arthroplasty and could be further evaluated for use with other musculoskeletal interventions.

  7. Obesity increases operating room times in patients undergoing primary hip arthroplasty: a retrospective cohort analysis.

    Science.gov (United States)

    Kadry, Bassam; Press, Christopher D; Alosh, Hassan; Opper, Isaac M; Orsini, Joe; Popov, Igor A; Brodsky, Jay B; Macario, Alex

    2014-01-01

    Background. Obesity impacts utilization of healthcare resources. The goal of this study was to measure the relationship between increasing body mass index (BMI) in patients undergoing total hip arthroplasty (THA) with different components of operating room (OR) time. Methods. The Stanford Translational Research Integrated Database Environment (STRIDE) was utilized to identify all ASA PS 2 or 3 patients who underwent primary THA at Stanford Medical Center from February 1, 2008 through January 1, 2013. Patients were divided into five groups based on the BMI weight classification. Regression analysis was used to quantify relationships between BMI and the different components of total OR time. Results. 1,332 patients were included in the study. There were no statistically significant differences in age, gender, height, and ASA PS classification between the BMI groups. Normal-weight patients had a total OR time of 138.9 min compared 167.9 min (P 35 kg/m(2) each incremental BMI unit increase was associated with greater incremental total OR time increases. Conclusion. Morbidly obese patients required significantly more total OR time than normal-weight patients undergoing a THA procedure. This increase in time is relevant when scheduling obese patients for surgery and has an important impact on health resource utilization.

  8. Obesity increases operating room times in patients undergoing primary hip arthroplasty: a retrospective cohort analysis

    Directory of Open Access Journals (Sweden)

    Bassam Kadry

    2014-08-01

    Full Text Available Background. Obesity impacts utilization of healthcare resources. The goal of this study was to measure the relationship between increasing body mass index (BMI in patients undergoing total hip arthroplasty (THA with different components of operating room (OR time. Methods. The Stanford Translational Research Integrated Database Environment (STRIDE was utilized to identify all ASA PS 2 or 3 patients who underwent primary THA at Stanford Medical Center from February 1, 2008 through January 1, 2013. Patients were divided into five groups based on the BMI weight classification. Regression analysis was used to quantify relationships between BMI and the different components of total OR time. Results. 1,332 patients were included in the study. There were no statistically significant differences in age, gender, height, and ASA PS classification between the BMI groups. Normal-weight patients had a total OR time of 138.9 min compared 167.9 min (P 35 kg/m2 each incremental BMI unit increase was associated with greater incremental total OR time increases. Conclusion. Morbidly obese patients required significantly more total OR time than normal-weight patients undergoing a THA procedure. This increase in time is relevant when scheduling obese patients for surgery and has an important impact on health resource utilization.

  9. Gait analysis, bone and muscle density assessment for patients undergoing total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Benedikt Magnússon

    2012-12-01

    Full Text Available Total hip arthroplasty (THA is performed with or without the use of bone cement. Facing the lack of reliable clinical guidelines on decision making whether a patient should receive THA with or without bone cement, a joint clinical and engineering approach is proposed here with the objective to assess patient recovery developing monitoring techniques based on gait analysis, measurements of bone mineral density and structural and functional changes of quadriceps muscles. A clinical trial was conducted with 36 volunteer patients that were undergoing THA surgery for the first time: 18 receiving cemented implant and 18 receiving non-cemented implant. The patients are scanned with Computer Tomographic (CT modality prior-, immediately- and 12 months post-surgery. The CT data are further processed to segment muscles and bones for calculating bone mineral density (BMD. Quadriceps muscle density Hounsfield (HU based value is calculated from the segmented file on healthy and operated leg before and after THA surgery. Furthermore clinical assessment is performed using gait analysis technologies such as a sensing carpet, wireless electrodes and video. Patients undergo these measurements prior-, 6 weeks post - and 52 weeks post-surgery. The preliminary results indicate computational tools and methods that are able to quantitatively analyze patient’s condition pre and post-surgery: The spatial parameters such as step length and stride length increase 6 weeks post op in the patient group receiving cemented implant while the angle in the toe in/out parameter decrease in both patient groups.

  10. Pre-operative Predictive Factors of Post-operative Pain in Patients With Hip or Knee Arthroplasty: A Systematic Review.

    Science.gov (United States)

    Hernández, Clara; Díaz-Heredia, Jorge; Berraquero, María Luisa; Crespo, Pablo; Loza, Estíbaliz; Ruiz Ibán, Miguel Ángel

    2015-01-01

    To analyze pre-surgical predictive factors of post-surgical pain in patients undergoing hip or knee arthoplasty. A systematic literature review was performed. We defined a sensitive strategy on Medline, Embase and Cochrane Library up to May 2013. The inclusion criteria were: patients undertaking knee and/or hip arthroplasty, adults with moderate or severe pain (≥4 on a Visual Analog Scale) in whom predictive factors of post-surgical pain were evaluated before surgery. Systematic reviews, meta-analyses, controlled trials and observational studies were selected. We excluded animals and basic science articles, reviews of prosthesis, prosthesis due to fractures, patients with rheumatic diseases or studies with mixed population in which disaggregated data was not possible to obtain. A total 37 articles of moderate quality were selected. The articles included representative patients undergoing a knee or hip arthroplasty in our country; most of them were aged 60 years or above, with osteoarthritis, and with a high rate of obesity and comorbidities. We found great variability regarding the type of studies and predictive factors. There was a strong association between post-surgical pain and the following pre-surgical factors: female gender, low socio-economic status, higher pain, comorbidities, low back pain, poor functional status, and psychological factors (depression, anxiety or catastrophic pain). There are pre-surgical factors that might influence post-surgical pain in patients undergoing a knee or hip arthroplasty. Therefore, they should be taken into account when considering an arthroplasty. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  11. Survivorship and complications of total hip arthroplasty in patients with dwarfism.

    Science.gov (United States)

    Modi, Ronuk M; Kheir, Michael M; Tan, Timothy L; Penny, Gregory S; Chen, Chi-Lung; Shao, Hongyi; Chen, Antonia F

    2017-09-19

    Total hip arthroplasty (THA) is a common procedure used to treat bony hip deformities and skeletal dysplasia in dwarfism. These surgeries are often more difficult than conventional THA as they may involve malformed joints and poor bone quality, and may require smaller prostheses. This study aims to investigate whether implant survivorship and revision rates vary among patients with and without dwarfism undergoing THA. A retrospective case-control study was performed for 102 THAs completed between 1997 and 2014 in patients under the height threshold of 147.32 cm. This cohort was matched 1:1.5 with patients of normal height with respect to age, gender, year of surgery, and Charlson comorbidities. All cases had a minimum follow-up of 1 year. A chart review was performed to identify patient and surgical characteristics, including outcomes. Radiographs were assessed for deformity, loosening, and periprosthetic fractures among other factors. The 2-, 5-, and 10-year survivorship of THA in patients with dwarfism was 92.9%, 92.9%, and 80.7%, respectively; and 94.4%, 86.4%, and 86.4% for controls, respectively (p = 0.95). The dwarfism cohort demonstrated an OR of 3.81 and 3.02 for revision for periprosthetic fractures (p = 0.11) and mechanical wear (p = 0.21), respectively. THA in patients with dwarfism achieves comparable results to a non-dwarfism population with regards to implant survivorship; however, there is a trend toward increased periprosthetic fractures and wear-related failures. Surgeons should be aware of this potentially higher risk in this population and take morphological differences into account during surgical planning and technique.

  12. Association between trochanteric bursitis, osteoarthrosis and total hip arthroplasty,

    OpenAIRE

    Carlos Roberto Schwartsmann; Felipe Loss; Leandro de Freitas Spinelli; Roque Furian; Marcelo Faria Silva; Júlia Mazzuchello Zanatta; Leonardo Carbonera Boschin; Ramiro Zilles Gonçalves; Anthony Kerbes Yépez

    2014-01-01

    OBJECTIVE: this was an epidemiological study on trochanteric bursitis at the time of performing total hip arthroplasty.METHODS: sixty-two sequential patients who underwent total hip arthroplasty due to osteoarthrosis, without any previous history of trochanteric bursitis, were evaluated. The bursas were collected and evaluated histologically.RESULTS: there were 35 female patients (56.5%) and 27 male patients (43.5%), with a mean age of 65 years (±11). Trochanteric bursitis was conformed histo...

  13. Differences in gait characteristics between total hip, knee, and ankle arthroplasty patients: a six-month postoperative comparison

    Science.gov (United States)

    2013-01-01

    Background The recovery of gait ability is one of the primary goals for patients following total arthroplasty of lower-limb joints. The aim of this study was to objectively compare gait differences of patients after unilateral total hip arthroplasty (THA), total knee arthroplasty (TKA) and total ankle arthroplasty (TAA) with a group of healthy controls. Methods A total of 26 TAA, 26 TKA and 26 THA patients with a mean (± SD) age of 64 (± 9) years were evaluated six months after surgery and compared with 26 matched healthy controls. Subjects were asked to walk at self-selected normal and fast speeds on a validated pressure mat. The following spatiotemporal gait parameters were measured: walking velocity, cadence, single-limb support (SLS) time, double-limb support (DLS) time, stance time, step length and step width. Results TAA and TKA patients walked slower than controls at normal (pTKA>THA). THA patients demonstrated no gait differences compared with controls. In contrast, TAA and TKA patients still demonstrated gait differences compared to controls, with slower walking velocity and reduced SLS in the involved limb. In addition, TAA patients presented marked side-to-side asymmetries in gait characteristics. PMID:23731906

  14. Arthroscopic bursectomy for recalcitrant trochanteric bursitis after hip arthroplasty.

    Science.gov (United States)

    Van Hofwegen, Christopher; Baker, Champ L; Savory, Carlton G; Baker, Champ L

    2013-01-01

    This study evaluated the use of arthroscopic bursectomy for pain relief in patients with trochanteric bursitis after hip arthroplasty. In this retrospective case series of 12 patients undergoing arthroscopic treatment of recalcitrant trochanteric bursitis after hip arthroplasty, outcomes were assessed via phone interview with a numeric pain rating scale from 1 to 10 and were compared with preoperative pain ratings. Patients were asked the percentage of time they had painless hip function and whether they would have the surgery again. At an average 36-month follow-up (range, 4-85 months), the average numeric pain scale rating improved from 9.3 to 3.3. At an average of 62% of the time, patients had painless use of the hip. Ten of 12 patients in the study felt the pain relief gained was substantial enough to warrant having procedure again. In these patients, arthroscopic bursectomy was a viable option for patients with recalcitrant bursitis after hip arthroplasty.

  15. Ceramic on ceramic arthroplasty of the hip: new materials confirm appropriate use in young patients.

    Science.gov (United States)

    Sentuerk, U; von Roth, P; Perka, C

    2016-01-01

    The leading indication for revision total hip arthroplasty (THA) remains aseptic loosening owing to wear. The younger, more active patients currently undergoing THA present unprecedented demands on the bearings. Ceramic-on-ceramic (CoC) bearings have consistently shown the lowest rates of wear. The recent advances, especially involving alumina/zirconia composite ceramic, have led to substantial improvements and good results in vitro. Alumina/zirconia composite ceramics are extremely hard, scratch resistant and biocompatible. They offer a low co-efficient of friction and superior lubrication and lower rates of wear compared with other bearings. The major disadvantage is the risk of fracture of the ceramic. The new composite ceramic has reduced the risk of fracture of the femoral head to 0.002%. The risk of fracture of the liner is slightly higher (0.02%). Assuming that the components are introduced without impingement, CoC bearings have major advantages over other bearings. Owing to the superior hardness, they produce less third body wear and are less vulnerable to intra-operative damage. The improved tribology means that CoC bearings are an excellent choice for young, active patients requiring THA. ©2016 The British Editorial Society of Bone & Joint Surgery.

  16. Good performance of a titanium femoral component in cementless hip arthroplasty in younger patients: 97 arthroplasties followed for 5-11 years

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Jensen, Frank Krieger; Poulsen, Klaus

    2003-01-01

    We performed 97 uncemented primary total hip arthroplasties in 80 patients having an average age of 50 years. The femoral implant was a titanium stem with a proximal circumferential plasma spray-coating. Three different acetabular components were used: a threaded and partly porous-coated design...... osteolysis associated with a deep infection, but no signs of proximal loosening. 3 femora had areas of minor proximal osteolysis. 16 acetabular components (14 threaded) had been revised in 13 patients. The average Harris hip score was 91 points at the latest follow-up. We conclude that the uncemented...... titanium femoral component with a circumferential porous coating performed well in these patients, most of whom were young. As reported previously, aseptic loosening of threaded acetabular components was common....

  17. Good performance of a titanium femoral component in cementless hip arthroplasty in younger patients: 97 arthroplasties followed for 5-11 years

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Jensen, Frank Krieger; Poulsen, Klaus

    2003-01-01

    We performed 97 uncemented primary total hip arthroplasties in 80 patients having an average age of 50 years. The femoral implant was a titanium stem with a proximal circumferential plasma spray-coating. Three different acetabular components were used: a threaded and partly porous-coated design...... osteolysis associated with a deep infection, but no signs of proximal loosening. 3 femora had areas of minor proximal osteolysis. 16 acetabular components (14 threaded) had been revised in 13 patients. The average Harris hip score was 91 points at the latest follow-up. We conclude that the uncemented...... titanium femoral component with a circumferential porous coating performed well in these patients, most of whom were young. As reported previously, aseptic loosening of threaded acetabular components was common....

  18. Systematic review: Do patient expectations influence treatment outcomes in total knee and total hip arthroplasty?

    Directory of Open Access Journals (Sweden)

    Haanstra Tsjitske M

    2012-12-01

    Full Text Available Abstract Objective This systematic review aims to summarise all the available evidence related to the association between pre-operative patient expectations (outcome expectations, process expectations and self efficacy expectations and 5 different treatment outcomes (overall improvement, pain, function, stiffness and satisfaction in patients with total knee or total hip arthroplasty at three different follow-op periods (>6 weeks; >6 weeks- ≤6 months; >6 months. Methods English and Dutch language articles were identified through PubMed, EMBASE.com, PsycINFO, CINAHL and The Cochrane Library from inception to September 2012. Articles assessing the association between pre-operative patient expectations and treatment outcomes for TKA/THA in either adjusted or unadjusted analysis were included. Two reviewers, working independently, determined eligibility, rated methodological quality and extracted data on study design, population, expectation measurements, outcome measurements and strength of the associations. Methodological quality was rated by the same reviewers on a 19 item scale. The scores on the quality assessment were taken into account when drawing final conclusions. Results The search strategy generated 2252 unique references, 18 articles met inclusion criteria. Scores on the methodological quality assessment ranged between 6% and 79%. Great variety was seen in definitions and measurement methods of expectations. No significant associations were found between patient expectations and overall improvement, satisfaction and stiffness. Both significant positive and non-significant associations were found for the association between expectations and pain and function. Conclusions There was no consistency in the association between patients’ pre-operative expectations and treatment outcomes for TKA and THA indentified in this systematic review. There exists a need for a sound theoretical framework underlying the construct of ‘patient

  19. Prioritisation of patients on waiting lists for hip and knee arthroplasties and cataract surgery: Instruments validation

    Directory of Open Access Journals (Sweden)

    Moharra Montse

    2008-04-01

    Full Text Available Abstract Background Prioritisation instruments were developed for patients on waiting list for hip and knee arthroplasties (AI and cataract surgery (CI. The aim of the study was to assess their convergent and discriminant validity and inter-observer reliability. Methods Multicentre validation study which included orthopaedic surgeons and ophthalmologists from 10 hospitals. Participating doctors were asked to include all eligible patients placed in the waiting list for the procedures under study during the medical visit. Doctors assessed patients' priority through a visual analogue scale (VAS and administered the prioritisation instrument. Information on socio-demographic data and health-related quality of life (HRQOL (HUI3, EQ-5D, WOMAC and VF-14 was obtained through a telephone interview with patients. The correlation coefficients between the prioritisation instrument score and VAS and HRQOL were calculated. For the reliability study a self-administered questionnaire, which included hypothetic patients' scenarios, was sent via postal mail to the doctors. The priority of these scenarios was assessed through the prioritisation instrument. The intraclass correlation coefficient (ICC between doctors was calculated. Results Correlations with VAS were strong for the AI (0.64, CI95%: 0.59–0.68 and for the CI (0.65, CI95%: 0.62–0.69, and moderate between the WOMAC and the AI (0.39, CI95%: 0.33–0.45 and the VF-14 and the CI (0.38, IC95%: 0.33–0.43. The results of the discriminant analysis were in general as expected. Inter-observer reliability was 0.79 (CI95%: 0.64–0.94 for the AI, and 0.79 (CI95%: 0.63–0.95 for the CI. Conclusion The results show acceptable validity and reliability of the prioritisation instruments in establishing priority for surgery.

  20. Current trends in total hip arthroplasty.

    Science.gov (United States)

    Eingartner, Christoph

    2007-01-01

    After 20 years of application, with excellent short-term and long-term results, uncemented total hip arthroplasty (THA) is now generally regarded as the standard procedure for younger patients undergoing THA. However, expectations regarding hip replacement are continuously rising, along with the increasing number of young and active patients undergoing hip arthroplasty: a complication rate, including postoperative dislocation, close to zero, faster postoperative rehabilitation, low wear even in active patients, high durability and long term survival, etc. Demographic changes in aging societies are also leading to an increased need for cost-effective THA for the low-demand trauma patient. For high-demand patients, modern THA bearings, such as ceramic-ceramic articulations and other improved PE and metal materials, provide high durability and low wear, if the components are properly aligned. Navigation technology has been introduced in THA to ensure perfect component positioning without outliers and concomitant risk of increased wear and implant failure. Minimally and less invasive approaches are becoming increasingly popular in order to facilitate rehabilitation and fast-track surgery in younger patients. Navigation provides assistance for implant positioning in procedures with limited surgical exposure and visibility. New bone-preserving implants, such as surface replacement or short-stemmed femoral shaft prostheses, have been introduced especially for younger patients. Some of these new procedures are still under development,and the long-term results of new implant concepts have to be evaluated over the next decades. Not every modern concept will likely stand the test of time, but some will be beneficial for patients undergoing total hip arthroplasty in the future.

  1. Early total hip arthroplasty for severe displaced acetabular fractures

    Institute of Scientific and Technical Information of China (English)

    YANG Shu-hua; ZHANG Yu-kun; XU Wei-hua; LI Jin; LIU Guo-hui; YANG Cao; LIU Yong; TIAN Hong-tao

    2006-01-01

    Objective : To investigate the effect of early total hip arthroplasty for severe displaced acetabular fractures.Methods: Total hip arthroplasty was performed on 17 cases of severe fracture of the acetabulum from 1997 to 2003. The mean follow-up was 2.1 years (1-6 years) and the average period from fracture to operation was 8 days (5-21 day). The average age of the patients was 53 years (26-69 years).Results: At the final follow-up the Harris hip score averaged 82(69-100) points and 15 cases have got a good outcome. There was one case of heterotopic bone formation. There were no radiographic evidences of late loosening of the prosthesis. One patient had severe central displacement of the cup.Conclusions: In patients with severe displaced acetabular fractures, particularly in elderly patients, early total hip arthroplasty is probably an alternative efficient way to achieve a painless and stable hip.

  2. Lateral femoral cutaneous nerve block after total hip arthroplasty

    DEFF Research Database (Denmark)

    Thybo, K H; Mathiesen, O; Dahl, J B

    2016-01-01

    reduce movement-related pain after total hip arthroplasty (THA) in patients with moderate-to-severe pain. METHODS: Sixty patients with visual analogue scale (VAS) score > 40 mm during 30-degree active flexion of the hip on either the first or second postoperative day after THA were included....... The overall non-responder rate (analgesic treatment regimen....

  3. Prosthetic Dislocation and Revision After Primary Total Hip Arthroplasty in Lumbar Fusion Patients: A Propensity Score Matched-Pair Analysis.

    Science.gov (United States)

    Perfetti, Dean C; Schwarzkopf, Ran; Buckland, Aaron J; Paulino, Carl B; Vigdorchik, Jonathan M

    2017-05-01

    Lumbar-pelvic fusion reduces the variation in pelvic tilt in functional situations by reducing lumbar spine flexibility, which is thought to be important in maintaining stability of a total hip arthroplasty (THA). We compared dislocation and revision rates for patients with lumbar fusion and subsequent THA to a matched comparison cohort with hip and spine degenerative changes undergoing only THA. We identified patients in New York State who underwent primary elective lumbar fusion for degenerative disc disease pathology and subsequent THA between January 2005 and December 2012. A propensity score match was performed to compare 934 patients with prior lumbar fusion to 934 patients with only THA according to age, gender, race, Deyo comorbidity score, year of surgery, and surgeon volume. Revision and dislocation rates were assessed at 3, 6, and 12 months post-THA. At 12 months, patients with prior lumbar fusion had significantly increased rates of THA dislocation (control: 0.4%; fusion: 3.0%; P < .001) and revision (control: 0.9%; fusion: 3.9%; P < .001). At 12 months, fusion patients were 7.19 times more likely to dislocate their THA (P < .001) and 4.64 times more likely to undergo revision (P < .001). Patients undergoing lumbar fusion and subsequent THA have significantly higher risks of dislocation and revision of their hip arthroplasty than a matched cohort of patients with similar hip and spine pathology but only undergoing THA. During preoperative consultation for patients with prior lumbar fusion, orthopedic surgeons must educate the patient and family about the increased risk of dislocation and revision. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Lower Limb Ischaemia Complicating Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Shiu-Wai Chan

    2012-06-01

    Full Text Available This article is about two patients having vascular injuries complicating total hip arthroplasty because of intraoperative indirect injuries. One patient had a delayed presentation of acute lower limb ischaemia, in which he required amputation of his left second toe because of ischaemic gangrene. The other patient had acute lower limb ischaemia leading to permanent muscle and nerve damage because of delayed recognition. Both patients had vascular interventions for the indirect vascular injuries. Preoperative workup for suspicious underlying peripheral vascular disease, intraoperative precautions, and perioperative period of vascular status monitoring are essential for prevention and early detection of such sinister events.

  5. Bone and muscle assessment in patients undergoing total hip arthroplasty using HU based analysis

    Directory of Open Access Journals (Sweden)

    Þröstur Pétursson

    2012-09-01

    Full Text Available Total hip arthroplasty (THA is performed with or without the use of bone cement. The lack of reliable clinical guidelines for deciding which one to implement has encouraged this approach of joint clinical and engineering with the following objectives: 1. Validate quadriceps muscles and femur bone atrophy by extracting the mineral density from Computer Tomographic (CT images. 2. Validate computational processes based on 3-D modeling and Finite Element Methods (FEM. A clinical trial was started, where 36 volunteer patients underwent THA surgery for the first time: 18 receiving cemented implant and 18 receiving uncemented implant. The patients were CT scanned prior-, immediately after and 12 months post-surgery. The CT data are further processed to segment muscles and bones and to create 3D-models for the simulation and for calculating bone mineral density (BMD. Furthermore quadriceps muscle density Hounsfield (HU based value is calculated from the segmented file on healthy and operated leg. These preliminary results indicate computational tools and methods that are able to quantitatively analyse patient’s condition pre and post-surgery. The BMD and muscle density measurement in correlation with the fracture risk analysis display a potential method for eligibility to receive non-cemented implant; the preliminary results show that also elderly that according with current clinical evaluation receives a cemented implant are suitable for the non-cemented type. The risk for structural failure during THA surgery is estimated by calculating femoral bone fracture risk index (FRI as a ratio between compressive stress during surgery and estimated failure stress on bone. The correlations with the BMD observations during the clinical trial will assess and validate this potential predictor tool.

  6. Clinical Outcomes of Total Hip Arthroplasty in Patients with Ankylosed Hip

    Directory of Open Access Journals (Sweden)

    Babak Siavashi

    2014-03-01

    Full Text Available Background:   Various drugs are administered intra-articularly to provide postoperative analgesia after arthroscopic knee surgery. The purpose of this study was to assess the analgesic effects of intra-articular injection of a dexmedetomidine   following knee arthroscopy.     Methods:   Forty six patients schadualed for arthroscopic knee surgery under general anaesthesia, were randomly devided into two groups. Intervention group received 1μg/kg dexmedetomidine (D and isotonic saline. Control group   received 25ml isotonic saline (P. Analgesic effects were evaluated by measuring pain intensity (VAS scores and   duration of analgesia.     Results:   There was no significant difference between the two groups in terms of age, sex and weight. The mean of post-operation pain severity in 1, 3, 6,12, and 24 h was significantly lower in the intervention group (D in comparison   with the control group (P. the mean of the total dose of tramadol consumption was significantly lower in the interven       tion group in comparison with the control group (     P

  7. Clinical Outcomes of Total Hip Arthroplasty in Patients with Ankylosed Hip

    Directory of Open Access Journals (Sweden)

    Babak Siavashi

    2014-03-01

    Full Text Available Background:   Various drugs are administered intra-articularly to provide postoperative analgesia after arthroscopic knee surgery. The purpose of this study was to assess the analgesic effects of intra-articular injection of a dexmedetomidine   following knee arthroscopy.     Methods:   Forty six patients schadualed for arthroscopic knee surgery under general anaesthesia, were randomly devided into two groups. Intervention group received 1μg/kg dexmedetomidine (D and isotonic saline. Control group   received 25ml isotonic saline (P. Analgesic effects were evaluated by measuring pain intensity (VAS scores and   duration of analgesia.     Results:   There was no significant difference between the two groups in terms of age, sex and weight. The mean of post-operation pain severity in 1, 3, 6,12, and 24 h was significantly lower in the intervention group (D in comparison   with the control group (P. the mean of the total dose of tramadol consumption was significantly lower in the interven       tion group in comparison with the control group (     P

  8. Pain and somatosensory findings in patients 3 years after total hip arthroplasty

    DEFF Research Database (Denmark)

    Nikolajsen, Lone; Kristensen, Anders Due Suzuki; Thillemann, Theis;

    2009-01-01

    (brush-evoked allodynia, pinprick hyperalgesia, mechanical and thermal thresholds). RESULTS: Brush-evoked allodynia was present in 4 patients with hip pain (P=0.1) and pinprick hyperalgesia (P=0.02) was more frequent in patients with chronic hip pain. Mechanical and thermal thresholds were similar...

  9. Perioperative management of hemophilia patients receiving total hip and knee arthroplasty: a complication report of two cases

    Directory of Open Access Journals (Sweden)

    Tateiwa T

    2015-09-01

    Full Text Available Toshiyuki Tateiwa,1 Yasuhito Takahashi,1,2 Tsunehito Ishida,1 Kosuke Kubo,1 Toshinori Masaoka,1 Takaaki Shishido,1 Keiji Sano,1 Kengo Yamamoto11Department of Orthopedic Surgery, 2Department of Bone and Joint Biomaterial Research, Tokyo Medical University, Tokyo, JapanAbstract: It has been recognized that perioperative hemostasis management after joint-replacement surgery for hemophilia patients is complicated and cumbersome, due to the necessity of rigorous monitoring for clotting-factor levels throughout the infusion. Between 2005 and 2014, we examined seven patients with hemophilia A (ten joints: six hips and four knees receiving total hip or knee arthroplasty (THA or TKA for hemophilic arthropathy. One male patient (31 years old showed an intra-articular hematoma formation after THA (case 1. In another male patient (46 years old receiving TKA, the postoperative trough factor VIII level became lower significantly than reference levels (80%–100% for the 5–10 postoperative days recommended by the guidelines from the Japanese Society on Thrombosis and Hemostasis, despite sufficient coagulant based on the guidelines being administered (case 2. In the latter patient, deep infection and hematoma formation were observed postoperatively. In this article, we provide a detailed clinical report regarding these two complication cases at the early postoperative periods, and the management of bleeding control for hemophilia patients is discussed.Keywords: hemophilia A, arthroplasty, clotting factor VIII levels, hematoma, infection

  10. Dislocation following revision total hip arthroplasty.

    Science.gov (United States)

    Gioe, Terence J

    2002-04-01

    Dislocation is a relatively common complication following revision total hip arthroplasty. Risk factors include surgical approach, gender, underlying diagnosis, comorbidities, surgical experience, and previous surgery; for later dislocations, risk factors include wear/deformation of polyethylene, trauma, and decreased muscle strength. Prevention and precaution are the watchwords for dislocations following revision total hip arthroplasty. For dislocations that do occur, treatment rests first on identifying the source of instability. Most dislocations can be managed by closed reduction. Constrained components may increase success rates, but only for appropriate indications. Prevention and treatment of dislocations following revision total hip arthroplasty are discussed in this article.

  11. In-hospital mortality analysis in patients with proximal femoral fracture operatively treated by hip arthroplasty procedure

    Directory of Open Access Journals (Sweden)

    Starčević Srdjan

    2016-01-01

    Full Text Available Background/Aim. Hip fracture remains the leading cause of death in trauma among elderly population and is a great burden to national health services. In-patient death analysis is important to evaluate risk factors, make appropriate selection and perform adequate treatment of infections for patients to be operated. The aim of this study was to analyze in-hospital mortality in proximal femoral fracture patients operatively treated with hip arthroplasty procedure. Methods. We followed 622 consecutive patients, and collected data about age, gender, the presence of infection preoperatively and postoperatively, American Society of Anesthesiologists (ASA score, diabetes mellitus and the type of surgical procedure. Postoperative infections included pneumonia, urinary tract infections, surgical site infections and sepsis. Results. We found a statistically significant influence of preoperative and postoperative infection presence for in-patient mortality with relative risk for lethal outcome of 4.53 (95% CI: 1.44-14.22 for patients with preoperative infection and 7.5 (95% CI: 1.90-29.48 for patients with postoperative infection. We did not confirm a statistically significant influence of age, gender, ASA score, diabetes mellitus or the type of surgical procedure for increased mortality rate. Conclusion. Adequate preoperative selection, risk evaluation and adequate treatment of infections are of the key importance for lowering the risk of death in patients operated due to proximal femoral fracture and treated by hip arthroplasty procedures. Special attention is to be paid for the presence of preoperative and postoperative infections in patients operatively treated due to the risk for increased in-hospital mortality.

  12. Periacetabular bone mineral density changes after resurfacing hip arthroplasty versus conventional total hip arthroplasty. A randomized controlled DEXA study

    NARCIS (Netherlands)

    Smolders, J.M.; Pakvis, D.F.M.; Hendrickx, B.W.; Verdonschot, N.J.; Susante, J.L.C. van

    2013-01-01

    A randomized controlled trial was performed to evaluate acetabular bone mineral density (BMD) changes after hip resurfacing (RHA) versus an established conventional total hip arthroplasty (THA). A total of 71 patients were allocated randomly to receive either an RHA press-fit cobalt-chromium cup (n=

  13. Periacetabular Bone Mineral Density Changes After Resurfacing Hip Arthroplasty Versus Conventional Total Hip Arthroplasty. A Randomized Controlled DEXA Study

    NARCIS (Netherlands)

    Smolders, J.M.H.; Pakvis, D.F.; Hendrickx, B.W.; Verdonschot, N.J.J.; Susante, van J.L.C.

    2013-01-01

    A randomized controlled trial was performed to evaluate acetabular bone mineral density (BMD) changes after hip resurfacing (RHA) versus an established conventional total hip arthroplasty (THA). A total of 71 patients were allocated randomly to receive either an RHA press-fit cobalt–chromium cup (n

  14. Medial Protrusio Technique in Cementless Total Hip Arthroplasty for Developmental Dysplasia of the Hip: A Prospective 6- to 9-Year Follow-Up of 43 Consecutive Patients.

    Science.gov (United States)

    Zha, Guo-Chun; Sun, Jun-Ying; Guo, Kai-Jin; Zhao, Feng-Chao; Pang, Yong; Zheng, Xin

    2016-08-01

    The medial protrusio technique may be used during total hip arthroplasty (THA) on patients with developmental dysplasia. However, studies have yet to determine whether a cementless cup can be sufficiently stable to withstand loading forces. This study aimed to assess the clinical and radiographic outcomes of this technique. Furthermore, we sought to determine the relationship between the rate of medial protrusion and the incidence of cup loosening. Thirty-nine patients (43 hips) underwent cementless THA between April 2006 and March 2009 by using the medial protrusio technique. These patients participated in a 6- to 9-year follow-up. Their clinical and radiographic data were gathered prospectively. The average Harris Hip Score improved from 43.1 ± 15.4 points preoperatively to 91.9 ± 12.8 points at the final follow-up (P hip center and the distance of hip center medialization were 2.4 ± 0.6 and 2.5 ± 0.9 cm, respectively. The rate of medial protrusion and the rate of cup coverage were 42.1 ± 12.4% and 96.8 ± 5.1%, respectively. The rate of medial protrusion ranged from 18.3% to 58.3% in 38 hips (group A) and from 61.3% to 68.9% in 5 hips (group B). None of the cups in group A loosened or failed, 2 failures occurred in group B (0% vs 40.0%; P = .011). Developmental dysplasia was treated through THA using the medial protrusio technique, which easily achieves a sufficient superolateral host bony coverage of the cup and promotes socket reconstruction at the true acetabulum. The rate of medial protrusion of <60% may be necessary to obtain excellent clinical and radiographic midterm results. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Cobalt toxicity after McKee hip arthroplasty.

    Science.gov (United States)

    Jones, D A; Lucas, H K; O'Driscoll, M; Price, C H; Wibberley, B

    1975-08-01

    The significance of cobalt as a cause of symptoms after McKee hip arthroplasty is discussed. Seven patients are described in whom such arthroplasties. became unsatisfactory after periods varying from nine months to four years. Six of these patients were cobalt-positive but nickel- and chrome-negative on patch testing. Macroscopic and histological necrosis of bone, muscle and joint capsule around the prostheses was found in five patients whose hips were explored. The symptoms were progressive pain, a feeling of instability, and in two cases spontaneous dislocation. Radiological features included acetabular fracture, bone resorption, loosening and dislocation of the prosthesis. Increased cobalt concentrations (determined by atomic absorption spectrophotometry) in the urine of four patients and in a variety of tissues in one patient are presented. Patch testing is recommended in the investigation of patients with troublesome McKee hip arthroplasties

  16. Total medical costs of treating femoral neck fracture patients with hemi- or total hip arthroplasty: a cost analysis of a multicenter prospective study

    NARCIS (Netherlands)

    P.T.P.W. Burgers (Paul); M. Hoogendoorn (Martine); E.A.C. Van Woensel; R.W. Poolman (Rudolf); M. Bhandari (Mohit); P. Patka (Peter); E.M.M. van Lieshout (Esther)

    2016-01-01

    textabstractSummary: The aim of this study was to determine the total medical costs for treating displaced femoral neck fractures with hemi- or total hip arthroplasty in fit elderly patients. The mean total costs per patient at 2 years of follow-up were €26,399. These results contribute to cost awar

  17. Total medical costs of treating femoral neck fracture patients with hemi- or total hip arthroplasty: a cost analysis of a multicenter prospective study

    NARCIS (Netherlands)

    P.T.P.W. Burgers (Paul); M. Hoogendoorn (Martine); E.A.C. Van Woensel; R.W. Poolman (Rudolf); M. Bhandari (Mohit); P. Patka (Peter); E.M.M. van Lieshout (Esther)

    2016-01-01

    textabstractSummary: The aim of this study was to determine the total medical costs for treating displaced femoral neck fractures with hemi- or total hip arthroplasty in fit elderly patients. The mean total costs per patient at 2 years of follow-up were €26,399. These results contribute to cost

  18. Association between trochanteric bursitis, osteoarthrosis and total hip arthroplasty,

    Directory of Open Access Journals (Sweden)

    Carlos Roberto Schwartsmann

    2014-06-01

    Full Text Available OBJECTIVE: this was an epidemiological study on trochanteric bursitis at the time of performing total hip arthroplasty.METHODS: sixty-two sequential patients who underwent total hip arthroplasty due to osteoarthrosis, without any previous history of trochanteric bursitis, were evaluated. The bursas were collected and evaluated histologically.RESULTS: there were 35 female patients (56.5% and 27 male patients (43.5%, with a mean age of 65 years (±11. Trochanteric bursitis was conformed histologically in nine patients (14.5%, of whom six were female (66.7% and three were male (33.3%.CONCLUSIONS: 14.5% of the bursas analyzed presented inflammation at the time that the primary total hip arthroplasty due to osteoarthrosis was performed, and the majority of the cases of bursitis were detected in female patients.

  19. Five Year Follow-up of One Stage Bilateral Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    CC Tai

    2007-04-01

    Full Text Available We report on the medium term outcome of five patients (ten hips who underwent one stage bilateral total hip arthroplasty. Both Harris Hip Scores and Oxford Hip Scores improved postoperatively as did range of motion. There was no radiographic evidence of loosening in any hip arthroplasty involved in this study, however one revision surgery was needed due to periprosthetic fracture. There were no increased medical complications. Based on our limited experience, we believe that one stage bilateral total hip arthroplasty is safe in selected patients.

  20. Patient out-of-pocket expenses in major orthopedic procedures: total hip arthroplasty as a case study.

    Science.gov (United States)

    Heiner, Daniel E; Mauerhan, David R; Masonis, John L; Heath, Jessica

    2008-06-01

    Total hip arthroplasty (THA) is a successful procedure for improving quality of life. There are few publications regarding out-of-pocket expenses incurred by individuals undergoing uncomplicated THA. Detailed billing and record reviews and patient phone surveys were conducted on 34 Medicare patients identifying charges and reimbursements recorded by the health care system and all out-of-pocket expenses incurred by patients undergoing uncomplicated THA (diagnostic related group [DRG] 209/current procedural terminology [CPT] 27130). Mean THA total billed charges were $46378, 89% of that from inpatient hospitalization and 5% incurred preoperatively and 7% postoperatively. Medicare reimbursement was $14647, supplemental reimbursement was $744, and patients paid a mean out-of-pocket expense of $758 (95% CI, 614-904; range, 102-1889). Our study supports the policy that THA remains an excellent value to both the patient and society.

  1. The Influence of Overweight/Obesity on Patient-Perceived Physical Functioning and Health-Related Quality of Life After Primary Total Hip Arthroplasty

    NARCIS (Netherlands)

    Stevens, Martin; Paans, Nienke; Wagenmakers, Robert; van Beveren, Jan; van Raay, Jos J. A. M.; van der Meer, Klaas; Stewart, Roy; Bulstra, Sjoerd K.; Reininga, Inge H. F.; van den Akker-Scheek, Inge

    Overweight/obesity in patients after total hip arthroplasty (THA) is a growing problem and is associated with postoperative complications and a negative effect on functional outcome. The objective of this study is to determine to what extent overweight/obesity is associated with physical functioning

  2. The Influence of Overweight/Obesity on Patient-Perceived Physical Functioning and Health-Related Quality of Life After Primary Total Hip Arthroplasty

    NARCIS (Netherlands)

    Stevens, Martin; Paans, Nienke; Wagenmakers, Robert; van Beveren, Jan; van Raay, Jos J. A. M.; van der Meer, Klaas; Stewart, Roy; Bulstra, Sjoerd K.; Reininga, Inge H. F.; van den Akker-Scheek, Inge

    2012-01-01

    Overweight/obesity in patients after total hip arthroplasty (THA) is a growing problem and is associated with postoperative complications and a negative effect on functional outcome. The objective of this study is to determine to what extent overweight/obesity is associated with physical functioning

  3. Tranexamic acid reduces blood loss and blood transfusions in primary total hip arthroplasty: a prospective randomized double-blind study in 40 patients

    DEFF Research Database (Denmark)

    Husted, Henrik; Blønd, Lars; Sonne-Holm, Stig;

    2003-01-01

    INTRODUCTION: We performed a prospective, randomized, double-blind study on 40 patients scheduled for primary total hip arthroplasty due to arthrosis or osteonecrosis to determine the effect of tranexamic acid on per- and postoperative blood losses and on the number of blood transfusions needed...

  4. Conversion of hip arthrodesis to total hip arthroplasty.

    Science.gov (United States)

    Panagiotopoulos, K P; Robbins, G M; Masri, B A; Duncan, C P

    2001-01-01

    rates of revision after converting an arthrodesed hip to a THA are quite high. The procedure can be complex. Consideration should be given to referring these patients to a specialized center under the care of an experienced arthroplasty surgeon if preoperative planning suggests that the conversion will not be straightforward.

  5. Treatment of acetabular fractures in older patients-introduction of a new implant for primary total hip arthroplasty.

    Science.gov (United States)

    Resch, H; Krappinger, D; Moroder, P; Auffarth, A; Blauth, M; Becker, J

    2017-04-01

    Fractures of the acetabulum in younger patients are commonly treated by open reduction and internal fixation. For elderly patients, stable primary total hip arthroplasty with the advantage of immediate postoperative mobilization might be the adequate treatment. For this purpose, a sufficiently stable fixation of the acetabular component is required. Between August 2009 and 2014, 30 cases were reported in which all patients underwent total hip arthroplasty additionally to a customized implant designed as an antiprotrusion cage. Inclusion criteria were an acetabular fracture with or without a previous hemiarthroplasty, age above 65 years, and pre-injury mobility dependent on a walking frame at the most. The median age was 79.9 years (65-92), and of 30 fractures, 25 were primary acetabular fractures (83%), four periprosthetic acetabular fractures (14%), and one non-union after a failed ORIF (3%). The average time from injury to surgery was 9.4 days (3-23) and 295 days for the non-union case. Mean time of surgery was 154.4 min (range 100 to 303). In 21 cases (70%), mobilization with full weight bearing was possible within the first 10 days. Six patients died before the follow-up examination 3 and 6 months after surgery, while 24 patients underwent radiologic examination showing consolidated fractures in bi-plane radiographs. In 9 patients, additional CT scan was performed which confirmed the radiographical results. 13 had regained their pre-injury level of mobility including the non-union case. Only one patient did not regain independent mobility. Four complications were recognized with necessary surgical revision (one prosthetic head dislocation, one pelvic cement leakage, one femoral shaft fracture, and one infected hematoma). The presented cage provides the possibility of early mobilization with full weight bearing which represents a valuable addition to the treatment spectrum in this challenging patient group.

  6. SOFT TISSUE BALANCING IN TOTAL HIP ARTHROPLASTY.

    Directory of Open Access Journals (Sweden)

    Pencho Kosev

    2015-03-01

    Full Text Available We present our experience with the soft tissue balancing in total hip arthroplasty. Detailed indications, planning and surgical technique are presented. The described procedures are performed on 278 hips for a period of 6 years (2008-2014. We conclude that the outcome of a THA can be improved by balancing the stability, ROM, muscle strength and limb length equality.

  7. Dilemmas in Uncemented Total Hip Arthroplasty

    NARCIS (Netherlands)

    Goosen, J.H.M.

    2009-01-01

    In this thesis, different aspects that are related to the survivorship and clinical outcome in uncemented total hip arthroplasty are analysed. In Chapter 2, the survival rate, Harris Hip score and radiographic features of a proximally hydroxyapatite coated titanium alloy femoral stem (Bi-Metric, Bio

  8. TOTAL HIP ARTHROPLASTY IN CHILDREN WHO HAVE UNDERGONE ARTHROPLASTY WITH DEMINERALIZED BONE-CARTILAGE ALLOCUPS

    Directory of Open Access Journals (Sweden)

    Vladimir E. Baskov

    2017-03-01

    Full Text Available Introduction. Treating children with degenerative dystrophic diseases of the hip joint has become one of the most acute problems in contemporary orthopedics. Until recently, we performed arthroplasty by demineralized bone-cartilage allocups (DBCA in the Clinic of the Hip Joint Pathology of the Turner Scientific and Research Institute for Children’s Orthopedics for patients showing clinical and radiological signs of irreversible destruction of the hip joint; we carried out this procedure to preserve the function of the lower limb. However, over the last 8 years, we have changed our protocol for children older than 12 years of age and have replaced DBCA with total hip replacement. In a number of cases, total hip replacement was performed after a previous intervention involving arthroplasty with DBCA. Objective. To determine the technical peculiarities of total hip replacement after a previous intervention involving arthroplasty with DBCA. Material and methods. We analyzed the results of treatment involving various types of hip pathology in 13 children (100% aged between 15 and 16 years [8 girls (61.5% and 5 boys (38.5%]. The medical histories of all 13 children (100% showed repeated operations on the hip joint, ultimately resulting in arthroplasty with DBCA. All 13 children (100% underwent a total hip replacement. Upon hip replacement, all 13 patients (100% showed a pronounced thinning and hardening of the edges and the bottom of the acetabulum, which created some difficulties in the process of acetabular component implantation. The transformation of DBCA was not evident in any of the 13 cases (100%. Results. During the observation period of 3–5 years following total hip arthroplasty, all 13 cases (100% showed recovery in the range of motion and absence of pain. An important criterion for evaluating the quality of care was the complete social and domestic adaptation of all 13 children (100% during the period from 6 to 9 months following total

  9. Total hip arthroplasty after previous fracture surgery.

    Science.gov (United States)

    Krause, Peter C; Braud, Jared L; Whatley, John M

    2015-04-01

    Total hip arthroplasty can be a very effective salvage treatment for both failed fracture surgery and hip arthritis that may occur after prior fracture surgery. The rate of complications is significantly increased including especially infection, dislocation, and loosening. Complications are more likely to occur after failed open reduction and internal fixation than after posttraumatic arthritis. Adequately ruling out infection before hip arthroplasty can be difficult. The best predictor of infection is a prior infection. Long-term outcomes can be comparable to outcomes in other conditions if complications are avoided.

  10. Medial Calcar Erosion Is Associated With Synovial Thickness in Patients With ASR XL Total Hip Arthroplasty.

    Science.gov (United States)

    Madanat, Rami; Rolfson, Ola; Donahue, Gabrielle S; Hussey, Daniel K; Potter, Hollis G; Wallace, Robert; Muratoglu, Orhun K; Malchau, Henrik

    2016-11-01

    Medial calcar erosion is considered a late finding in patients with severe adverse local tissue reactions (ALTRs) after total hip arthroplasty (THA) with dual modular neck stems. Although calcar erosion has been associated with dual modular neck stems, one would expect similar findings in standard stems owing to analogous corrosion at the taper junction. The aim of this study was to evaluate whether medial calcar erosion is also associated with ALTR in patients with standard stems in metal-on-metal (MoM) THA. A total of 96 patients (108 hips) with MoM THA had radiographs and a magnetic resonance imaging of the hip performed at a mean time of 5.7 years after surgery. Calcar erosion was assessed from radiographs. ALTR Anderson grade, diameter, volume, and synovial thickness were assessed from magnetic resonance imaging. Calcar erosion was present in 54 hips (50%) and was associated with ALTR synovial thickness but not with Anderson grade, diameter, or volume. Most of the hips with calcar erosion (n = 45) had an ALTR (positive predictive value 0.83, 95% confidence interval 0.70-0.92). The relative risk of having a synovial thickness > 3 mm increased by a factor of 3.0 (95% confidence interval 1.3-6.5) if calcar erosion was observed. Subtle erosions of the medial calcar after MoM THA may be an early indicator of an adverse reaction to wear particles warranting cross-sectional imaging. Synovial thickness may also be more relevant than absolute size in the classification of ALTR severity and collateral tissue damage. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Naproxen prevention of heterotopic ossification after hip arthroplasty. A prospective control study of 55 patients

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Soelberg, M; Orsnes, T

    1991-01-01

    The effect of naproxen on heterotopic ossification after total hip replacement was studied in a randomized, double-blind trial. Twenty-eight patients received 250 mg naproxen thrice daily for 4 weeks postoperatively starting on the morning of the operation while 27 control patients received a pla...

  12. Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty.

    Science.gov (United States)

    Ladon, Dariusz; Doherty, Ann; Newson, Roger; Turner, Justine; Bhamra, Manjit; Case, C Patrick

    2004-12-01

    A prospective study was performed to investigate changes in metal levels and chromosome aberrations in patients within 2 years of receiving metal-on-metal hip arthroplasties. There was a statistically significant increase of cobalt and chromium concentrations, with a small increase in molybdenum, in whole blood at 6, 12, and 24 months after surgery. There was also a statistically significant increase of both chromosome translocations and aneuploidy in peripheral blood lymphocytes at 6, 12, and 24 months after surgery. The changes were generally progressive with time, but the change in aneuploidy was much greater than in chromosome translocations. No statistically significant correlations were found in secondary analyses between chromosome translocation indices and cobalt or chromium concentration in whole blood. Although the clinical consequences of these changes, if any, are unknown, future epidemiological studies could usefully include direct comparisons of patients with implants of different composition.

  13. Comparison of acetabular reamings during hip resurfacing versus uncemented total hip arthroplasty.

    LENUS (Irish Health Repository)

    Brennan, S A

    2009-04-01

    PURPOSE: To compare the quantity of bone removed from the acetabulum during resurfacing hip arthroplasty versus uncemented total hip arthroplasty (THA). METHODS: 62 consecutive patients with osteoarthritis of the hip were prospectively studied. 24 men and 7 women aged 40 to 86 (mean, 59) years underwent Birmingham hip resurfacing. 13 men and 18 women aged 34 to 88 (mean, 61) years underwent uncemented THA using the trident acetabular cup. Obese elderly women at risk of femoral neck fracture and patients with large subchondral pseudocysts or a history of avascular necrosis of the femoral head were assigned to uncemented THA. Acetabular reamings were collected; marginal osteophytes were not included. The reamings were dehydrated, defatted, and weighed. RESULTS: The mean weight of acetabular reamings was not significantly different between patients undergoing hip resurfacing and uncemented THA (p=0.57). CONCLUSION: In hip resurfacing, the use of an appropriately small femoral component avoids oversizing the acetabular component and removal of excessive bone stock.

  14. Developmental hip dysplasia treated by total hip arthroplasty using a cementless Wagner cone stem in young adult patients with a small physique.

    Science.gov (United States)

    Zhen, Ping; Liu, Jun; Lu, Hao; Chen, Hui; Li, Xusheng; Zhou, Shenghu

    2017-05-15

    Developmental hip dysplasia (DDH) may lead to severe acetabular and femoral abnormalities that can render total hip arthroplasty (THA) challenging, especially in DDH patients with a small physique. Most conventional cemented or cementless femoral components are often difficult to implant in the narrow femoral canal and require slight version correction during surgery. The aim of this study was to present the mid-term results of THA in the treatment of DDH patients with a small physique using a cementless Wagner cone prosthesis (Zimmer®, US). Between January 2006 and March 2010, we retrospectively reviewed 50 patients who were treated at our center. A total of 50 patients (52 hips; 45 women, five men; mean age 32.5 years; range 27 to 38 years) who underwent THA were observed. The mean femoral medullary canal dimension at the isthmus was 7.6 mm (range 6.0 to 8.7). According to the Crowe classification, 19 hips presented dysplasia of grade I, while 33 presented dysplasia of grade II. All patients were treated with THA using a cementless Wagner cone prosthesis. Clinical and radiologic evaluations were performed on all patients. The mean duration of follow-up was 7.7 years (range 5.4 to 10.5). The Harris hip score (HHS) improved from 63 ± 9 (range 55 to 70) pre-operatively to 92 ± 8 (range 88 to 100) at the last follow-up. The HHS at the most recent follow-up was excellent in 66% of patients (34 hips), good in 26% (14 hips), fair in 6% (3 hips), and poor in 2% (1 hip). Radiographic evaluation demonstrated excellent osteointegration of the implants. Stem subsidence was present in three stems, and the range of stem subsidence was 2 mm in two stems (3.9%) and 3 mm in one stem (1.9%). Femoral osteolysis was observed in nine hips (18%) in the proximal zones, and no distal osteolysis was noted. Heterotopic ossification was observed in three hips (5.8%); of these, two were classified as Brooker's grade 1, and one was classified as Brooker's grade 2 at the most

  15. Total Hip Arthroplasty in Failed Hip Fractures: A Case Series

    Directory of Open Access Journals (Sweden)

    Syed Shahid Noor

    2015-01-01

    Full Text Available Osteoporosis is epidemic in Asian countries. It is a major cause of fractures that orthopaedic surgeons deal in Pakistan, though proper epidemiological data is not available. Habiba U et al found that 75.3% of post menopausal women of Pakistan were predisposed to Osteoporosis; whereas Baig L has described an average T - score of -1.833±0.65 on bone mineral density calculation of post menopausal females of Pakistan. Osteoporotic hip fractures constitute a major cause of elderly mortality worldwide and recent figures supporting the idea that these patients have survival rates comparable to breast and thyroid cancer patients. Pakistan is a developing country with large burden of hip fractures. Patients living in remote areas are the ones which suffer more because of inadequate awareness, fear of surgical treatment and lack of availability of standard treatment. These patients are dealt by surgeons of various expertise and levels of experience. Lack of facilities in hospitals is well known and usage of sub-standard implant is a major cause of failure. Therefore these patients either because of their bone fragility or mal-treatment suffer frequently from failure of hip fracture surgeries. Being in a tertiary care centre we come across these types of cases very frequently. Six to eight such cases present to outpatient department of Liaquat National Hospital every month being referred from every part of the country. These patients may have been operated once, twice or even multiple times. Special attention is required to acquire an informative history from these cases and perform a comprehensive examination. Moreover previous records and radiographs provide invaluable information regarding cause of failure and deciding course of further treatment. We herein discuss few of the cases of failure of hip fractures which were treated by hip arthroplasty.

  16. Validation of the diagnosis 'prosthetic joint infection' in the Danish Hip Arthroplasty Register

    DEFF Research Database (Denmark)

    Gundtoft, Per Hviid; Pedersen, A B; Schønheyder, HC;

    2016-01-01

    AIMS: The purpose of this study was to validate the diagnosis of periprosthetic joint infection (PJI) in the Danish Hip Arthroplasty Register (DHR). PATIENTS AND METHODS: We identified a cohort of patients from the DHR who had undergone primary total hip arthroplasty (THA) since 1 January 2005 an...

  17. Nursing experience of preoperative standardized for patients with total hip arthroplasty.%人工全髋关节置换术前规范化护理体会

    Institute of Scientific and Technical Information of China (English)

    梁勇东

    2012-01-01

    Objective:Through the analysis of artificial total hip arthroplasty in patients' nursing before operations, to discuss the preoperative standardized nursing of artificial total hip arthroplasty. Methods:The adequate preoperative preparation of 108 total hip replacement patients and the strengthening of preoperative rehabilitation guidance. Results:108 artificial total hip replacement patients can tolerate surgery, grasp the rehabilitation guidance content, and actively cooperate with therapy and nursing, no case of complications such as pressure sores and dislocations. Conclusion:Standardized preoperative care is the important prerequisite for success of total hip arthroplasty.%目的:通过回顾分析人工全髋关节置换术患者术前的护理,探讨人工全髋关节置换术前规范化护理方法.方法:对108例人工全髋关节置换术患者进行了充分的术前准备和加强术前康复指导.结果:本组108例患者能耐受手术,能掌握康复指导内容,积极配合治疗和护理,无1例发生压疮、脱位等并发症.结论:规范化的术前护理是人工全髋关节置换术成功的重要前提.

  18. Minimally invasive total hip arthroplasty: in opposition.

    Science.gov (United States)

    Hungerford, David S

    2004-06-01

    At the Knee Society Winter Meeting in 2003, Seth Greenwald and I debated about whether there should be new standards (ie, regulations) applied to the release of information to the public on "new developments." I argued for the public's "right to know" prior to the publication of peer-reviewed literature. He argued for regulatory constraint or "proving by peer-reviewed publication" before alerting the public. It is not a contradiction for me to currently argue against the public advertising of minimally invasive (MIS) total hip arthroplasty as not yet being in the best interest of the public. It is hard to remember a concept that has so captured both the public's and the surgical community's fancy as MIS. Patients are "demanding" MIS without knowing why. Surgeons are offering it as the next best, greatest thing without having developed the skill and experience to avoid the surgery's risks. If you put "minimally invasive hip replacement" into the Google search engine (http://www.google.com), you get 5,170 matches. If you put the same words in PubMed (http://www.ncbi.nlm.nih.gov/entrez/query.fcgi), referencing the National Library of Medicine database, you get SEVENTEEN; none is really a peer-reviewed article. Most are 1 page papers in orthopedics from medical education meetings. On the other hand, there are over 6,000 peer-reviewed articles on total hip arthroplasty. Dr. Thomas Sculco, my couterpart in this debate, wrote an insightful editorial in the American Journal of Orthopedic Surgery in which he stated: "Although these procedures have generated incredible interest and enthusiasm, I am concerned that they may be performed to the detriment of our patients." I couldn't agree with him more. Smaller is not necessarily better and, when it is worse, it will be the "smaller" that is held accountable.

  19. The Consumer Quality Index Hip Knee Questionnaire measuring patients' experiences with quality of care after a total hip or knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Delnoij Diana MJ

    2007-04-01

    Full Text Available Abstract Background The Dutch Consumer Quality Index Hip Knee Questionnaire (CQI Hip Knee was used to assess patients' experiences with and evaluations of quality of care after a total hip (THA or total knee arthroplasty (TKA. The aim of this study is to evaluate the construct validity and internal consistency reliability of this new instrument and to assess its ability to measure differences in quality of care between hospitals. Methods Survey data of 1,675 subjects who underwent a THA or TKA were used to evaluate the psychometric properties. Exploratory factor analyses were performed and item-total correlations and inter-factor correlations were calculated to assess the construct validity of the instrument. Reliability analyses included tests of internal consistency (Cronbach's alpha coefficients. Finally, multilevel analyses were performed to assess the ability of the instrument to discriminate between hospitals in quality of care. Results Exploratory factor analyses indicated that the survey consisted of 21 items measuring five aspects of care (i.e. communication with nurses, communication with doctors, communication with general practitioner, communication about new medication, and pain control. Cronbach's alpha coefficients ranged from 0.76 to 0.90 indicating good internal consistency. The survey's ability to discriminate between hospitals was partly supported by multilevel analysis. Two scales (i.e. communication with nurses and communication with doctors were able to measure differences between hospitals with respect to patients' experiences with quality of care. Logistic multilevel analyses indicated that hospitals explained part of the variation between patients in receiving information. Conclusion These findings suggest that the CQI Hip Knee is reliable and valid for use in Dutch health care. Health care providers or health plans can use this survey to measure patients' experiences with hospital care and to identify variations in care

  20. The effects of pulsed low frequency magnetic field in early rehabilitation of patients with cementless total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Đurović Aleksandar

    2006-01-01

    Full Text Available Introduction: Early rehabilitation of patients with cementless total hip arthroplasty (cTHA includes different physical modalities and pulsed low frequency magnetic field (PLFMF, which effects have not been explored yet. Objective: To investigate the effects of PLFMF which was applied in different doses in early rehabilitation of patients with cTHA. Method: Prospective, controlled, clinical study included 90 patients, divided in three groups with 30 patients each. First two groups were treated with high (group A or low (group B doses of PLFMF, in addition to kinesitherapy. Control group C was treated only with kinesitherapy. Study was completed in three weeks. Results: Subjects of group A had significantly lower pain than group B (p<0.01 and group C (p<0.001 subjects in the first postoperative week. Pain in group B subjects was significantly lower than in group C in all three postoperative weeks (p<0.01. In relation to other two groups, subjects of group A had higher hip Harris score values at the end of the third postoperative week (p<0.05, and they were faster on 10-meter distance at the end of the first postoperative week (p<0.01. Conclusion: PLFMF used in low and high doses for patients with cTHA had significant effects on pain abatement, especially at higher doses. Improvement of function was earlier and more manifested in the group treated with high doses of PLFMF.

  1. Bilaterally Primary Cementless Total Hip Arthroplasty for Severe Hip Ankylosis with Ankylosing Spondylitis.

    Science.gov (United States)

    Feng, Dong-Xu; Zhang, Kun; Zhang, Yu-Min; Nian, Yue-Wen; Zhang, Jun; Kang, Xiao-Min; Wu, Shu-Fang; Zhu, Yang-Jun

    2016-08-01

    Total hip arthroplasty is a reliable therapeutic intervention in patients with ankylosing spondylitis, in whom the aims of surgery are to reduce pain, restore hip function and improve quality of life. The current study is a retrospective analysis of the clinical and radiographic findings in a consecutive series of patients with hip ankylosis associated with severe ankylosing spondylitis who underwent bilateral primary total hip arthroplasty using non-cemented components. From June 2008 to May 2012, total hip arthroplasty was performed on 34 hips in 17 patients with bilateral ankylosis caused by ankylosing spondylitis. The study patients included 13 men and 4 women with a mean age of 24.2 years. The mean duration of disease was 8.3 years and the average duration of hip involvement was 7.6 years. All patients had severe hip pain and dysfunction with bilateral bony ankylosis and no range of motion preoperatively and all underwent bilateral cementless total hip arthroplasty performed by a single surgeon. Joint pain, range of motion (ROM), and Harris hip scores were assessed to evaluate the postoperative results. At a mean follow-up of 31.7 months, all patients had experienced significant clinical improvement in function, ROM, posture and ambulation. At the final follow-up, the mean postoperative flexion ROM was 134.4° compared with 0° preoperatively. Similar improvements were seen in hip abduction, adduction, internal rotation and external rotation. Postoperatively, 23 hips were completely pain-free, six had only occasional discomfort, three mild to moderate pain and two severe pain. The average Harris Hip Score improved from 23.7 preoperatively to 65.8 postoperatively. No stems had loosened at the final follow-up in any patient, nor had any revision surgery been required. Bilateral severe hip ankylosis in patients with ankylosing spondylitis can be treated with cementless bilateral synchronous total hip arthroplasty, which can greatly improve hip joint function and

  2. Double mobility cup total hip arthroplasty in patients at high risk for dislocation: a single-center analysis.

    Science.gov (United States)

    Kaiser, Dominik; Kamath, Atul F; Zingg, Patrick; Dora, Claudio

    2015-12-01

    Double mobility cup systems (DMCS) have gained increasing acceptance, especially in patients at high risk for dislocation. The aim of this investigation was to analyze the frequency and indications of the DMCS use in our praxis and to evaluate dislocation and cup revision rates after a minimum follow-up of 2 years. All patients implanted with a DMCS from May 2008 to August 2011 were identified from our institutional database of primary and revision THA procedures. Patient demographics, including ASA score, were recorded, along with details of the surgical procedures, indications for DMCS use, and post-operative clinical course and any complications. Radiographs were analyzed for implant positioning and radiological signs of loosening. 1046 primary THA were implanted, of these 39 (4 %) primary DMCS. Indications were severe neuromuscular disease (SND) (14), hip abductor degeneration (HAD) (9), cognitive dysfunction (CD) (8) and others. 345 revision THA were performed, of these 50 (14 %) revision DMCS. Indications were recurrent dislocations (27), multiple prior hip surgeries (13), HAD (5), CD (3) and others. Overall dislocation rate was 2/89 (2 %); both in revision THA. Overall cup revision rate was 5/89 (6 %): 3 septic, 1 periprosthetic acetabular fracture, 1 "intraprosthetic dissociation". 67 patients were available for the standardized questionnaire at a median follow-up of 43 months (range 25-78). 19 patients were not available for two-year follow-up: 17 died and two were lost to follow-up. This study supports the use of DMCS constructs in primary and revision hip arthroplasty for specific high-risk patients. We continue to indicate DMCS in this patient group. We do caution against extending indications for DMCS to lower risk patient groups due to unknown issues surrounding wear and component longevity.

  3. History and factors of survival of total hip arthroplasty.

    Science.gov (United States)

    Kolundžić, Robert; Trkulja, Vladimir; Orlić, Dubravko

    2012-02-01

    Since the 1960s total hip arthroplasty (THA) has represented one of the greatest accomplishments in orthopedic surgery. It improves the functionality, working ability and quality of life of patients with non-functional hip joint due to various reasons. This article reviews general and regional history of THA, current knowledge and concepts regarding the long-term outcomes of the procedure and emphasizes the need for establishing national (and international) THA registries as an essential way of gathering data critical for decision making in daily practice as well as in defining national healthcare policies in respect to arthroplasty procedures.

  4. Prevalence of modifiable surgical site infection risk factors in hip and knee joint arthroplasty patients at an urban academic hospital.

    Science.gov (United States)

    Pruzansky, Jason S; Bronson, Michael J; Grelsamer, Ronald P; Strauss, Elton; Moucha, Calin S

    2014-02-01

    Surgical site infections after hip and knee arthroplasty can be devastating if they lead to periprosthetic joint infection. We examined the prevalence of the modifiable risk factors for surgical site infection described by the American Academy of Orthopaedic Surgery Patient Safety Committee. Our study of 300 cases revealed that only 20% of all cases and 7% of revision cases for infection had no modifiable risk factors. The most common risk factors were obesity (46%), anemia (29%), malnutrition (26%), and diabetes (20%). Cases with obesity or diabetes were associated with all histories of remote orthopedic infection, 89% of urinary tract infections, and 72% of anemia cases. The high prevalence of several modifiable risk factors demonstrates that there are multiple opportunities for perioperative optimization of such comorbidities.

  5. Reverse-total shoulder arthroplasty cost-effectiveness: A quality-adjusted life years comparison with total hip arthroplasty.

    Science.gov (United States)

    Bachman, Daniel; Nyland, John; Krupp, Ryan

    2016-02-18

    To compare reverse-total shoulder arthroplasty (RSA) cost-effectiveness with total hip arthroplasty cost-effectiveness. This study used a stochastic model and decision-making algorithm to compare the cost-effectiveness of RSA and total hip arthroplasty. Fifteen patients underwent pre-operative, and 3, 6, and 12 mo post-operative clinical examinations and Short Form-36 Health Survey completion. Short form-36 Health Survey subscale scores were converted to EuroQual Group Five Dimension Health Outcome scores and compared with historical data from age-matched patients who had undergone total hip arthroplasty. Quality-adjusted life year (QALY) improvements based on life expectancies were calculated. The cost/QALY was $3900 for total hip arthroplasty and $11100 for RSA. After adjusting the model to only include shoulder-specific physical function subscale items, the RSA QALY improved to 2.8 years, and its cost/QALY decreased to $8100. Based on industry accepted standards, cost/QALY estimates supported both RSA and total hip arthroplasty cost-effectiveness. Although total hip arthroplasty remains the quality of life improvement "gold standard" among arthroplasty procedures, cost/QALY estimates identified in this study support the growing use of RSA to improve patient quality of life.

  6. Cementless two-stage exchange arthroplasty for infection after total hip arthroplasty.

    Science.gov (United States)

    Masri, Bassam A; Panagiotopoulos, Kostas P; Greidanus, Nelson V; Garbuz, Donald S; Duncan, Clive P

    2007-01-01

    We retrospectively reviewed all patients at one center with an infected total hip arthroplasty treated with 2-stage revision using cementless components for the second stage and the PROSTALAC articulated spacer at the first stage. Twenty-nine patients were reviewed and followed for at least 2 years postoperatively. An isolated Staphylococcus species was cultured in 76% (22/29) of patients. Three (10.3%) of 29 patients had recurrent infection at the site of the prosthesis. One of the 3 patients ultimately underwent a Girdlestone arthroplasty. Another patient was managed with irrigation and debridement, whereas the final patient was treated with intravenous antibiotics alone. Treatment of infection at the site of a hip arthroplasty with 2-stage revision using cementless components and an articulated spacer yields recurrence rates similar to revisions where at least one of the components at the second stage is fixed with antibiotic-loaded cement.

  7. Clinical Evaluation of Fused/Ankylosed Hip with Severe Flexion Deformity after Conversion to Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Saroj Kumar Suwal

    2016-06-01

    Conclusions: THA is an effective treatment for ankylosed hip with severe flexion deformity although complications are noted more than routine hip arthroplasties. Keywords: ankylosed hip; fused hip; severe flexion deformity; total hip arthroplasty. | PubMed

  8. Gluteal tendon reconstruction in association with hip arthroplasty.

    Science.gov (United States)

    Bajwa, Ali S; Campbell, David G; Comely, Andrew S; Lewis, Peter L

    2011-01-01

    We studied a prospective cohort of patients in whom gluteal tendon reconstruction was undertaken in association with hip arthroplasty. Over the course of 10 years, 24 patients had gluteal tendon reconstruction performed either at the time of hip arthroplasty or post-operatively, using the Ligament Augment and Reconstruction System (LARS), suture anchors, direct suture to bone, or a combination of these techniques. All patients were assessed clinically and by patient-centred outcome measures, including the hip disability and osteoarthritis score (HOOS). The mean post-operative HOOS was significantly better than pre-operative score (p pain, activities of daily living (ADL), sports and quality of life (QoL) was 72 (SD 12.8), 73 (SD 15.9), 71 (SD 11.8), 54 (SD 22.6) and 57 (SD 21.76) respectively. There were two failures of gluteal tendon reconstruction which required revision using LARS. One patient died of an unrelated cause. Surgical intervention should be considered in gluteal tendinopathy at the time of hip arthroplasty or when symptoms occur following arthroplasty.

  9. [Is suction drainage necessary in elective total hip arthroplasty?].

    Science.gov (United States)

    Major, Tibor; Bikov, András; Holnapy, Gergely; Bejek, Zoltán; Bakos, Bernadett; Szendrői, Miklós; Skaliczki, Gábor

    2016-07-01

    Several studies have been published which questioned the use of suction drain during elective hip arthroplasty. In this prospective study the authors examined how the use of suction drainage affected complications related to perioperative blood loss and hemorrhage in patients undergoing elective hip arthroplasty. Eighty-six patients undergoing elective hip arthroplasty were divided into two groups. In 54 patients ("drain" group) suction drains were used during operation, whereas in 32 patients no suction drain was applied. Perioperative blood loss, use of tranexamic acid, method of thrombosis prophylaxis, transfusion requirement, incidental postoperative hemorrhage, septic complications, and all other postoperative complications were recorded. Perioperative blood loss was affected with the use of tranexamic acid but not with the use of drainage (p = 0.94). Patients without the use of drain showed a tendency of lower transfusion requirement (p = 0.08). There was no correlation between any complications and the use of drainage. In accordance with published results the authors conclude that the routine use of suction drainage during elective hip arthroplasty is not definitely necessary. Orv. Hetil., 2016, 157(29), 1171-1176.

  10. CUSTOMIZED ACETABULAR COMPONENTS IN REVISION HIP ARTHROPLASTY

    Directory of Open Access Journals (Sweden)

    G. M. Kavalersky

    2016-01-01

    Full Text Available In recent years, there is a trend of increasing demand for revision hip arthroplasty. Among these patients there are many with complex acetabular defects, including patients with pelvic discontinuity. To ensure stability for revised acetabular components in such cases becomes a challenging or unachievable task. Such defects give indications for printing customized tri-flange acetabular component. The authors analysed own experience of creating and applying custom made acetabular components in 3 patients with complex acetabular defects. Material and methods. Among the patients there were 2 women and 1 man. Average age was 60,3±19,4 years (38 to 78 years. Two patients had III B defects with pelvic discontinuity and one patient had III A defect by Paprosky classification. As the first step, the authors in collaboration with engineers printed a plaster full size pelvic 3D model, as the second step a customized tri-flange acetabular component was designed and printed. Harris Hip Score was evaluated preoperatively and 3 months postoperatively. Results. Average follow-up period was 5,3±2,5 months (3 to 8 months. The authors observed no cases of implant loosening, dislocation or deep periprosthetic infection. Average Harris Hip Score before surgery was 27,13 and after surgery – 74,1 indicating a significant improvement in 3 months postoperatively. Conclusion. Indications for use of individual acetabular components in reported patients correspond to indications formulated by Berasi et al. The authors obtained encouraging early follow-up outcomes that correspond to data of other authors. In one patient certain difficulties were reported due to insufficient pelvic distraction. Component’s flanges prevented achieving adequate pelvic distraction. Nevertheless, good primary stability was achieved. Modern software and 3D metal printers can significantly reduce the production cost of customized acetabular components. Application of this technology can be

  11. Resection arthroplasty of the hip in paralytic dislocations.

    Science.gov (United States)

    Kalen, V; Gamble, J G

    1984-06-01

    The chronically dislocated paralytic hip causes postural difficulties, nursing and hygiene problems, and pain. Therapeutic options are limited. This study reviews the results of resection arthroplasty on 18 hips of 15 such patients. This procedure has many complications, including hip ankylosis, heterotopic ossification, abduction contracture and bony overgrowth. Despite this, all of the nursing goals were achieved and most patients had relief of pain. The operation is most successful in the skeletally mature patients, and it relies on soft-tissue interposition between the bony fragments and postoperative positioning to ensure optimum posture.

  12. The association between metal allergy, total hip arthroplasty, and revision

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Jakobsen, Stig Storgaard; Engkilde, Kåre;

    2009-01-01

    in general with THA. Furthermore, we compared the prevalence of metal allergy in dermatitis patients with and without THA. MATERIALS AND METHODS: The Danish Hip Arthroplasty Registry (DHAR) contained detailed information on 90,697 operations. The Gentofte patch-test database contained test results...

  13. Health Care Needs and Support for Patients Undergoing Treatment for Prosthetic Joint Infection following Hip or Knee Arthroplasty: A Systematic Review

    Science.gov (United States)

    Beswick, Andrew D.; Peters, Tim J.; Gooberman-Hill, Rachael; Whitehouse, Michael R.; Blom, Ashley W.

    2017-01-01

    Background Hip and knee arthroplasty are common interventions for the treatment of joint conditions, most notably osteoarthritis. Although many patients benefit from surgery, approximately 1% of patients develop infection afterwards known as deep prosthetic joint infection (PJI), which often requires further major surgery. Objective To assess support needs of patients undergoing treatment for PJI following hip or knee arthroplasty and to identify and evaluate what interventions are routinely offered to support such patients. Design Systematic review Data sources MEDLINE, EMBASE, Web of Science, PsycINFO, Cinahl, Social Science Citation Index, The Cochrane Library, and reference lists of relevant studies from January 01, 1980 to October 05, 2016. Selection criteria Observational (prospective or retrospective cohort, nested case-control or case-control) studies, qualitative studies, or clinical trials conducted in patients treated for PJI and/or other major adverse occurrences following hip or knee arthroplasty. Review methods Data were extracted by two independent investigators and consensus was reached with involvement of a third. Given the heterogeneous nature of study designs, methods, and limited number of studies, a narrative synthesis is presented. Results Of 4,213 potentially relevant citations, we identified one case-control, one prospective cohort and two qualitative studies for inclusion in the synthesis. Patients report that PJI and treatment had a profoundly negative impact affecting physical, emotional, social and economic aspects of their lives. No study evaluated support interventions. Conclusion The findings demonstrate that patients undergoing treatment for PJI have extensive physical, psychological, social and economic support needs. The interpretation of study results is limited by variation in study design, outcome measures and the small number of relevant eligible studies. However, our review highlights a lack of evidence about support

  14. Hip arthroplasty in a patient with transfemoral amputation: a new tip.

    Science.gov (United States)

    Boussakri, Hassan; Alassaf, Ihab; Hamoudi, Samir; Elibrahimi, Abdelhalim; Ntarataz, Philbert; ELMrini, Abdelmajid; Dumez, Jean Francois

    2015-01-01

    Femoral fractures in amputation stump are challenging injuries to manage. The authors describe a case of a 51-year-old patient with a right above knee amputation, who had a right hip femoral neck fracture. In this technical note, we describe a technical and surgical procedure with intraoperative tips and tricks, in which we use commonly available materials, for the safe management in such clinical situations.

  15. Hip Arthroplasty in a Patient with Transfemoral Amputation: A New Tip

    Directory of Open Access Journals (Sweden)

    Hassan Boussakri

    2015-01-01

    Full Text Available Femoral fractures in amputation stump are challenging injuries to manage. The authors describe a case of a 51-year-old patient with a right above knee amputation, who had a right hip femoral neck fracture. In this technical note, we describe a technical and surgical procedure with intraoperative tips and tricks, in which we use commonly available materials, for the safe management in such clinical situations.

  16. Bosworth hip shelf arthroplasty in adult dysplastic hips: ten to twenty three year results.

    Science.gov (United States)

    Bartoníček, Jan; Vávra, Jaroslav; Chochola, Antonín

    2012-12-01

    Hip shelf arthroplasty is currently considered to be a salvage procedure. The aim of the study is to present outcomes of Bosworth hip shelf arthroplasty in adolescent dysplastic hips with a minimum ten-year follow-up. The basic group comprised 25 hips in 18 patients with the mean age of 31 years (range, 16-52) at the time of operation. Subgroup A included 20 hips that were evaluated prior to operation as spherical, centric hips without osteoarthritic changes (acetabular dysplasia). The heterogeneous subgroup B comprised five hips. Of these, three hips were evaluated as aspheric, without osteoarthritic changes, and two hips as aspheric, with osteoarthritic changes of grade 2 according to Tönnis. In addition, two hips in subgroup B were evaluated as decentred (subluxated), one hip without and one hip with osteoarthritic changes. The mean follow-up was 15 years (range, ten-23). In subgroup A, the positive effect of operation had lasted at the time of the final follow-up for ten to 22 years postoperatively (average follow-up 14 years) in 19 hips. Only one female patient, 46 years old at the time of operation, developed hip osteoarthritis within ten years, that was treated by THA. In subgroup B, a lasting positive effect of operation was recorded in two cases at the time of the final follow-up (12 and 15 years). The third female patient with an aspheric and decentred hip developed severe hip osteoarthritis 21 years after shelf procedure that was treated by THA. In two patients who had hip osteoarthritis already before the operation, the positive effect of the shelf procedure survived over 13 and 20 years. Although hip osteoarthritis progressed, THA was performed as late as 15 and 23 years after the shelf procedure. The mean Harris hip score in 21 hips with a still functional hip shelf was 68 (range, 56-82) before and 90 (range, 76-100) after the surgery. The best outcomes of Bosworth hip shelf arthroplasty may be expected in a dysplastic spherical centred hip

  17. Metal-on-Metal Hip Arthroplasty: A Review of Adverse Reactions and Patient Management

    Directory of Open Access Journals (Sweden)

    James Drummond

    2015-06-01

    Full Text Available Recent alarming joint registry data highlighting increased revision rates has prompted further research into the area of metal-on-metal hip replacements and resurfacings. This review article examines the latest literature on the topic of adverse reactions to metal debris and summarises the most up-to-date guidelines on patient management. Adverse reactions to metal debris can cause significant damage to soft tissue and bone if not diagnosed early. Furthermore, not every patient with an adverse reaction to metal debris will be symptomatic. As such, clinicians must remain vigilant when assessing and investigating these patients in order to detect failing implants and initiate appropriate management.

  18. Dilemmas in Uncemented Total Hip Arthroplasty

    OpenAIRE

    Goosen, J. H. M.

    2009-01-01

    In this thesis, different aspects that are related to the survivorship and clinical outcome in uncemented total hip arthroplasty are analysed. In Chapter 2, the survival rate, Harris Hip score and radiographic features of a proximally hydroxyapatite coated titanium alloy femoral stem (Bi-Metric, Biomet) was evaluated. In conclusion, at an average follow-up of 8 years, this proximally HA-coated femoral component showed favorable clinical and radiological outcome and excellent survivorship. In ...

  19. Revision rate of Birmingham Hip Resurfacing arthroplasty: comparison of published literature and arthroplasty register data.

    Science.gov (United States)

    Schuh, Reinhard; Neumann, Daniel; Rauf, Rauend; Hofstaetter, Jochen; Boehler, Nikolaus; Labek, Gerold

    2012-07-01

    Hip resurfacing arthroplasty has gained popularity for treating young and active patients who have arthritis. There are two major data sources for assessing outcome and revision rate after total joint arthroplasty: sample-based clinical trials and national arthroplasty registers. The purpose of this study was to evaluate the outcome of the Birmingham Hip Resurfacing (BHR) arthroplasty in terms of revision rate as reported in clinical studies and recorded by national arthroplasty registers. A comprehensive literature research was performed from English-language, peer-reviewed journals and annual reports from national joint arthroplasty registers worldwide. Only publications from MEDLINE-listed journals were included. The revision rate was used as the primary outcome parameter. In order to allow for direct comparison of different data sets, calculation was based on revisions per 100 observed component years. For statistical analysis, confidence intervals (CI) were calculated. A total of 18,708 implants, equivalent to 106,565 observed component years, were analysed in the follow-up studies. The register reports contained 9,806 primary cases corresponding to 44,294 observed component years. Statistical analysis revealed a significant difference in revisions per 100 observed component years between the development team (0.27; CI: 0.14-0.40) and register data (0.74; CI: 0.72-0.76). The BHR arthroplasty device shows good results in terms of revision rate in register data as well as in clinical studies. However, the excellent results reported by the development team are not reproducible by other surgeons. Based on the results of our study, we believe that comprehensive national arthroplasty registers are the most suitable tool for assessing hip arthroplasty revision rate.

  20. UNCEMENTED PRIMARY TOTAL HIP ARTHROPLASTY FOR OSTEONECROSIS OF HIP WITH SECONDARY OSTEOARTHRITIS IN YOUNG ADULTS

    Directory of Open Access Journals (Sweden)

    Chatla

    2016-03-01

    Full Text Available BACKGROUND Osteonecrosis of the femoral head is a progressive disease that generally affects patients in the third through fifth decade of life, if left untreated. Currently, 18% of all Total Hip Arthroplasty performed in USA are done for Osteonecrosis.(1 The aetiology for the Osteonecrosis varies from idiopathic, alcohol intoxication, steroid abuse or due to childhood hip disorders and hip trauma. We have selected 40 patients suffering from advanced femoral head osteonecrosis with subchondral collapse leading to Osteoarthritis of hip in young adults, treated by uncemented primary total hip replacement. This study is aimed to suggest that uncemented total hip arthroplasty can be applied predictably to this younger, potentially more active patient population. MATERIAL AND METHODS We have done 54 uncemented primary hips in 40 cases with mean follow-up of 5.5 years. The average age of the patient at the time of surgery was 43 years. All the hips are clinically and radiologically examined both pre- and post-operatively. All the cases are operated through postero-lateral approach and have used the fully Hydroxyapatite coated femoral straight stem designed for press fit insertion and hemispherical HA-coated cup inserted with press fit and in few cases we used an HA-coated screw. The patients are under regular follow-up. RESULTS All the patients are reviewed at 6 weeks, 3 months, 6 months and yearly thereafter. The clinical and functional status was recorded using the Harris Hip Score and WOMAC Hip Score. The mean Harris score has improved from an average of 44 points to an average of 93 points postoperatively; 94% showed good-to-excellent results, 2% of cases had shortening, one case developed hip dislocation after two weeks due to unguarded physiotherapy. CONCLUSION The short-term results of cementless total hip arthroplasty in patients with Osteonecrosis of the femoral head were encouraging. We await further follow-up to see if these promising

  1. Total hip arthroplasty in patients with bone deficiency of the acetabulum.

    Science.gov (United States)

    Choplin, Robert H; Henley, Christopher N; Edds, Eric M; Capello, William; Rankin, James L; Buckwalter, Kenneth A

    2008-01-01

    Total hip replacement (THR) requires revision in only a minority of cases (approximately 17% of prosthetic hips fail), but when THR failures occur there may be significant acetabular bone deficiency. There is a variety of surgical hardware and strategies available to address this problem. The causes of primary THR revision include aseptic loosening or particle disease, infection, recurrent dislocation, implant failure, periprosthetic fracture, and leg length discrepancy. Almost all patients who need THR revision undergo a standard radiographic evaluation of the pelvis and hip. In general, CT is an excellent tool for evaluating loosening of the prosthesis caused by either mechanical reasons or infection, and MR imaging is best suited for evaluating the soft tissues surrounding the prosthesis. Nuclear medicine studies are performed when results of CT and MR imaging are inconclusive. When patients are evaluated for revision THR, radiologists must check for acetabular cup loosening, the amount and type of bone stock loss, the amount of component migration, and the presence or absence of liner wear. Before revision hardware is placed, bone stock loss must be repaired, either by using bone grafting or by placing accessory acetabular hardware such as cups, rings, or cages. The long-term success of revision acetabular surgery varies; there is acetabular cup presence at 5 years after surgery in 60%-94% of cases. Complications include postoperative infections, repeat liner wear, bone graft failure, periprosthetic or prosthetic fractures, dislocation, vascular injury, and nerve injury. Copyright RSNA, 2008.

  2. Efficacy of drainage blood reinfusion in early postoperative period after total hip arthroplasty in patients with rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    N B Shelokova

    2008-01-01

    Full Text Available To study effect of drainage blood reinfusion in early postoperative period (EPP after total hip arthroplasty (THA in patients with rheumatoid arthritis (RA. Material and methods. Primary THA was performed in 51 RA pts with hip damage (49 female, 2 male aged from 26 to 68 years. 42 THA were performed with “Endosystems and Implants” (ESI endoprosthesis, and 21 — with “Mathys” endoprosthesis. The pts were divided into two groups. Standard infusion-transfusion therapy with donor blood components was performed in group 1 pts (n=26 to compensate blood loss in EPP. In group 2 pts (n=25 drainage blood reinfusion was done with active aspiration system Handy Vac TM ATS (Unomedical. Group 1 pts had more prominent circulatory and neurologic disturbances in EPP: hypodynamic variant of circulation with elevation of peripheral vascular resistance till 5-7 day of postoperative period, prominent hypersympathicotonia and a large number of posttransfusion reactions. Evaluation of hemodynamic and vegetative disturbances showed advantage of blood loss compensation and vegetative disturbances normalization with drainage blood reinfusion in EPP after THA in comparison with standard pts management.

  3. Evaluation of the fixation of the trabecular metal wedge in patients undergoing revision of total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Victor Magalhães Callado

    2014-08-01

    Full Text Available Objective:this study aimed to evaluate the fixation of the trabecular metal wedge in patients undergoing revision of total hip arthroplasty.Methods:twenty-three cases with minimum grading of Paprosky II-B that were operated between July 2008 and February 2013 were evaluated. These cases were evaluated based on radiographs before the operation, immediately after the operation and later on after the operation. Loss of fixation was defined as a change in the abduction angle of the component greater than 10° or any mobilization greater than 6 mm.Results:it was found that there was 100% fixation of the acetabula after a mean of 29.5 months. One case underwent removal of the implanted components due to infection.Conclusions:there is still no consensus regarding the best option for reconstructing hips with bone loss. However, revision using a trabecular metal wedge has presented excellent short-and medium-term results. This qualifies it as an important tool for achieving a fixed and stable acetabular component.

  4. Comparison of different pseudotumor grading systems in a single cohort of metal-on-metal hip arthroplasty patients

    Energy Technology Data Exchange (ETDEWEB)

    Weegen, W. van der; Wullems, J.A.; Das, H.P. [St. Anna Hospital, Department of Orthopaedic Surgery, Geldrop (Netherlands); Brakel, K.; Horn, R.J. [St. Anna Hospital, Department of Radiology, Geldrop (Netherlands); Pilot, P. [Reinier de Graaf Gasthuis, Department of Orthopaedic Surgery, Delft (Netherlands); Nelissen, R.G. [Leids Universitair Medisch Centrum, Department of Orthopaedic Surgery, Leiden (Netherlands)

    2014-02-15

    Follow-up of pseudotumors observed with metal-artefact reducing sequence (MARS)-magnetic resonance imaging (MRI) following metal-on-metal total hip arthroplasty (MoMTHA) depends on how severe these pseudotumors are graded. Several pseudotumor grading systems for MARS-MRI have emerged but little is known of their validity. We studied the intra- and interobserver reliability of three different pseudotumor grading systems in a single cohort of MoMTHA. Two experienced musculoskeletal radiologists independently used three different pseudotumor grading systems for classifying MARS-MRI results of the same cohort of 42 MoMTHA patients (49 hips, mean follow-up 5.2 years). Intraobserver and interobserver reliability for each grading system was measured using Cohen's kappa (κ). Variance in pseudotumor severity grading between systems was analyzed. Intraobserver reliability on grading pseudotumor severity with the Anderson, Matthies, and Hauptfleisch grading system scored 0.47, 0.10, and 0.35 (observer 1), and 0.75, 0.38, and 0.42 (observer 2), respectively. Interobserver reliability scores for pseudotumor severity were 0.58, 0.23, and 0.34, respectively. Intraobserver reliability for grading pseudotumor severity on MARS-MRI ranged from poor to good, dependent on observer and grading system used. Interobserver reliability scored best with the Anderson system. A more succinct pseudotumor severity grading system is needed for clinical use. (orig.)

  5. Hip and knee arthroplasty: quo vadis?

    NARCIS (Netherlands)

    Ho, J.; Meis, J.F.G.M.; Nabuurs-Franssen, M.H.; Voss, A.

    2015-01-01

    Despite of the steady decrease of surgical site infection (SSI) over the last two decades, the incidence of SSI after hip and knee arthroplasty has recently surged. This may be explained by technical changes that may result in an increased risk of SSI, such as the broad implementation of fast track

  6. Serum levels of BMP-2, 4, 7 and AHSG in patients with degenerative joint disease requiring total arthroplasty of the hip and temporomandibular joints.

    Science.gov (United States)

    Albilia, Jonathan B; Tenenbaum, Howard C; Clokie, Cameron M L; Walt, David R; Baker, Gerald I; Psutka, David J; Backstein, David; Peel, Sean A F

    2013-01-01

    To date, there is no objective or reliable means of assessing the severity of degenerative joint disease (DJD) and need for joint replacement surgery. Hence, it is difficult to know when an individual with DJD has reached a point where total arthroplasty is indicated. The purpose of the present study is to determine whether serum levels of Alpha-2 HS-glycoprotein (AHSG) as well as bone morphogenetic proteins (BMP-2, 4, 7) can be used to predict the presence of severe DJD of the hip and/or temporomandibular joint (TMJ) (specifically: joints that require replacement). A total of 30 patients scheduled for arthroplasty (diseased) (15 HIP, 15 TMJ) and 120 age-matched controls (healthy/non-diseased) were included. Blood samples were collected from all patients ≥8 weeks after the last arthroplasty. Concentrations of serum analytes were measured using enzyme-linked immunosorbent assays, and these were compared between the Diseased and Healthy groups, utilizing the Mann-Whitney U-test. Patients with disease had significantly higher levels of BMP-2 and BMP-4 and lower levels of AHSG in serum compared to non-diseased humans (p < 0.01). Higher levels of BMP-2, 4 and reduced levels of AHSG appear to characterize patients who have DJD that is severe enough to require total joint replacement. Perhaps measurements of these proteins can be used to make objective decisions regarding the need for total arthroplasty as opposed to the current subjective approaches.

  7. Fourth-generation ceramic-on-ceramic total hip arthroplasty in patients of 55 years or younger: short-term results and complications analysis

    Institute of Scientific and Technical Information of China (English)

    Wang Weiguo; Guo Wanshou; Yue Debo; Shi Zhencai; Zhang Nianfei; Liu Zhaohui; Sun Wei

    2014-01-01

    Background The incidence of total hip replacement in the younger and more active patients is ever increasing.The ceramic-on-ceramic (COC) bearing was developed to reduce wear debris-induced osteolysis and loosening and to improve the longevity of hip arthroplasties.Few studies have reported the clinical results and complications of the new zirconia-toughened ceramic total hip arthroplasty (THA).Methods A consecutive series of 132 young patients (177 hips) that underwent primary cementless THAs between January 2010 and December 2012 were included in this study.These arthroplasties all had fourth-generation COC bearings performed through a posterolateral approach.The average age was (41.8±8.3) years (ranging from 22 to 55 years),and the mean follow-up period was (24.5±9.4) months (ranging from 12 to 47 months).The results were evaluated both clinically and radiographically.Harris hip score (HHS) was determined before surgery and at the time of each follow-up.Presence of postoperative groin or thigh pain and squeaking were recorded.Other complications such as dislocations,periprosthetic fractures,and ceramic components fractures were diagnosed and treated in emergency.Results The average HHSs improved from preoperative 60.3±10.7 (ranging from 29 to 76) to 91.0±5.1 (ranging from 74 to 100) at the final follow-up (t=-45.064,P <0.05),and 97.7% of cases were scored as excellent and good results.At the last follow-up,incidental inguinal pain was found in three hips (1.7%) and thigh pain in 11 hips (6.2%).Radiographs showed a high rate of new bone formation around the acetabular and stem components.No obvious osteolysis or prosthesis loosening was detected.Complications occurred in six hips (3.4%):posterior dislocation in two hips (1.1%),periprosthetic femoral fracture in one hip (0.6%),asymptomatic squeaking in two hips (1.1%),and ceramic liner fracture in one hip (0.6%).Conclusions The fourth-generation COC THA showed excellent clinical results in

  8. Anterior iliopsoas impingement after total hip arthroplasty.

    Science.gov (United States)

    Trousdale, R T; Cabanela, M E; Berry, D J

    1995-08-01

    Pain after total hip arthroplasty (THA) can be caused by a multitude of conditions, including infection, aseptic loosening, heterotopic ossification, and referred pain. It is also recognized that soft tissue inflammation about the hip, such as trochanteric bursitis, can lead to hip pain after THA. Two cases of persistent iliopsoas tendinitis following THA are reported, which are believed to be caused by psoas tendon impingement against a malpositioned, uncemented, metal-backed acetabular component. The authors are unaware of previous reports of this problem, and suggest that the problem be considered in the differential diagnosis of groin pain following THA.

  9. The natural history of inflammatory pseudotumors in asymptomatic patients after metal-on-metal hip arthroplasty.

    Science.gov (United States)

    Almousa, Sulaiman A; Greidanus, Nelson V; Masri, Bassam A; Duncan, Clive P; Garbuz, Donald S

    2013-12-01

    Although pseudotumors have been reported in 32% of asymptomatic metal-on-metal hips, the natural history of asymptomatic pseudotumors is unknown. The purpose of this study was to assess changes over time in asymptomatic pseudotumors and the effect of revision on pseudotumor mass. Followup ultrasound was performed a mean of 25.8 months (range, 21-31 months) after the detection of 15 pseudotumors and five isolated fluid collections in a cohort of 20 asymptomatic patients (13 metal-on-metal, three metal-on-polyethylene, and four hip resurfacings) [42]. Changes in pseudotumors and fluid collections size and nature, and serum ion levels were determined. Among the 15 nonrevised patients, pseudotumors increased in size in six (four solid and two cystic) of 10 patients, three of which had clinically important increases (13-148 cm(3); 28-74 cm(3); 47-104 cm(3)). Three pseudotumors (one solid and two cystic) disappeared completely (the largest measured 31 cm(3)). One solid pseudotumor decreased in size (24 to 18 cm(3)). In five revised patients, pseudotumors completely disappeared in four patients. The fifth patient had two masses that decreased from 437 cm(3) to 262 cm(3) and 43 cm(3) to 25 cm(3). All revision patients had a reduction of chromium (40.42 μ/L to 2.69 μ/L) and cobalt ions (54.19 μ/L to 0.64 μ/L). Of five isolated fluid collections, four completely disappeared (two metal-on-metal and two metal-on-polyethylene) and one (metal-on-metal) increased from 26 cm(3) to 136 cm(3). Our observations suggest pseudotumors frequently increase in size in asymptomatic patients with occasional remission of small masses. Revision resulted in remission of pseudotumors.

  10. Inflammatory pseudotumor of the hip: a complication of arthroplasty to be recognized by the radiologist

    Directory of Open Access Journals (Sweden)

    Raquel de Melo Santos Vilas Boas

    2015-10-01

    Full Text Available AbstractSoft tissue complications following hip arthroplasty may occur either in cases of total hip arthroplasty or in hip resurfacing, a technique that has become popular in cases involving young patients. Both orthopedic and radiological literatures are now calling attention to these symptomatic periprosthetic soft tissue masses called inflammatory pseudotumors or aseptic lymphocytic vasculites-associated lesions. Pseudotumors are associated with pain, instability, neuropathy, and premature loosening of prosthetic components, frequently requiring early and difficult reoperation. Magnetic resonance imaging plays a relevant role in the evaluation of soft tissue changes in the painful hip after arthroplasty, ranging from early periprosthetic fluid collections to necrosis and more extensive tissue damage.

  11. The effect of relaxation techniques and back massage on pain and anxiety in Turkish total hip or knee arthroplasty patients.

    Science.gov (United States)

    Büyükyılmaz, Funda; Aştı, Türkinaz

    2013-09-01

    The purpose of this study was to examine the effects of relaxation techniques and back massage on postoperative pain, anxiety, and vital signs on postoperative days 1-3 in patients who had undergone total hip or knee arthroplasty (THA, TKA). Sixty patients having a THA or TKA were randomly assigned to either a experimental group or a control group. The McGill Pain Questionnaire Short Form (MPQ-SF) and State Anxiety Inventory (SAI) were used to measure pain and anxiety, respectively. Vital signs, including blood pressure (systolic and diastolic), pulse, and respiratory rate, were also obtained. Statistically significant differences in pain intensity (F = 14.50; p = .000), anxiety level (F = 19.13; p = .000), and vital signs (F = 169.61, 9.14, 14.23, 65.64; p = .000) measured over time were found between the experimental and the control group. Results of this research provide evidence to support the use of relaxation techniques and back massage at bed rest times of patients to decrease pain and anxiety. The interventions helped them to forget about their pain for a while and improved their anxiety state. After an evaluation of the conclusions, use of these interventions should be implemented by nurses into routine plans of care for patients. Copyright © 2013 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.

  12. Hip dislocations after 2,734 elective unilateral fast-track total hip arthroplasties

    DEFF Research Database (Denmark)

    Jørgensen, Christoffer C; Kjaersgaard-Andersen, Per; Solgaard, Søren

    2014-01-01

    characteristics from six Danish arthroplasty departments with similar fast-track approaches were cross-referenced with the Danish National Patient Registry for complete 90-day follow-up on readmissions, including emergency-room contacts. Complete patient files and postoperative radiographs were reviewed in case.......31-3.40)] but not hospital stay of fast-track total hip...

  13. Utilization rates of hip arthroplasty in OECD countries.

    Science.gov (United States)

    Pabinger, C; Geissler, A

    2014-06-01

    Hip arthroplasty and revision surgery is growing exponentially in OECD countries, but rates vary between countries. We extracted economic data and utilization rates data about hip arthroplasty done in OECD countries between 1990 and 2011. Absolute number of implantations and compound annual growth rates were computed per 100,000 population and for patients aged 65 years old and over and for patients aged 64 years and younger. In the majority of OECD countries, there has been a significant increase in the utilization of total hip arthroplasty in the last 10 years, but rates vary to a great extent: In the United States, Switzerland, and Germany the utilization rate exceeds 200/100,000 population whereas in Spain and Mexico rates are 102 and 8, respectively. There is a strong correlation between gross domestic product (GDP) and health care expenditures per capita with utilization rate. Utilization rates in all age groups have continued to rise up to present day. A seven fold higher growth rate was seen in patients aged 64 years and younger as compared to older patients. We observed a 38-fold variation in the utilization of hip arthroplasty among OECD countries, correlating with GDP and health care expenditures. Over recent years, there has been an increase in the utilization rate in most countries. This was particularly evident in the younger patients. Due to increasing life expectancy and the disproportionally high use of arthroplasty in younger patients we expect an exponential increase of revision rate in the future. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  14. Total joint arthroplasties: current concepts of patient outcomes after surgery.

    Science.gov (United States)

    Jones, C Allyson; Beaupre, Lauren A; Johnston, D W C; Suarez-Almazor, Maria E

    2007-02-01

    Total hip and knee arthroplasties are effective surgical interventions for relieving hip pain and improving physical function caused by arthritis. Although the majority of patients substantially improve, not all report gains or are satisfied after receiving total joint arthroplasty. This article reviews the literature on patient outcomes after total hip and knee arthroplasties for osteoarthritis, and the evidence pertaining to factors that affect these patient-centered outcomes. Mounting evidence suggests that no single patient-related or perioperative factor clearly predicts the amount of pain relief or functional improvement that will occur following total hip or knee arthroplasty.

  15. Distal femoral shortening in total hip arthroplasty for complex primary hip reconstruction. A new surgical technique.

    Science.gov (United States)

    Koulouvaris, Panagiotis; Stafylas, Kosmas; Sculco, Thomas; Xenakis, Theodore

    2008-10-01

    Successful total hip arthroplasty (THA) in congenital dislocated hips demands anatomical reduction in the normal center of rotation without overstretching the sciatic nerve and without excessive compression or abnormal forces across the joint. Proximal femoral and subtrochanteric shortening osteotomy has been described for THA for the treatment of dislocated hips. However, these osteotomies are demanding, associated with deformation of femoral canal and nonunion, and may increase the femoral stem stress. This study reports excellent results in 24 patients with a new surgical technique that combines THA with a distal femoral shortening in severely deformed hips using customized components.

  16. Perioperative blood saving measures in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Horstmann, W.G.

    2011-01-01

    This dissertation explores and discusses different aspects of blood loss and blood-saving measures in total hip and knee arthroplasty. Background: Worldwide, approximately 1 million total hip and 1 million total knee prostheses are implanted each year. Total hip arthroplasty and total knee art

  17. Fourth-generation ceramic-on-ceramic total hip arthroplasty in patients of 55 years or younger: short-term results and complications analysis.

    Science.gov (United States)

    Wang, Weiguo; Guo, Wanshou; Yue, Debo; Shi, Zhencai; Zhang, Nianfei; Liu, Zhaohui; Sun, Wei; Wang, Bailiang; Li, Zirong

    2014-01-01

    The incidence of total hip replacement in the younger and more active patients is ever increasing. The ceramic-on-ceramic (COC) bearing was developed to reduce wear debris-induced osteolysis and loosening and to improve the longevity of hip arthroplasties. Few studies have reported the clinical results and complications of the new zirconia-toughened ceramic total hip arthroplasty (THA). A consecutive series of 132 young patients (177 hips) that underwent primary cementless THAs between January 2010 and December 2012 were included in this study. These arthroplasties all had fourth-generation COC bearings performed through a posterolateral approach. The average age was (41.8 ± 8.3) years (ranging from 22 to 55 years), and the mean follow-up period was (24.5 ± 9.4) months (ranging from 12 to 47 months). The results were evaluated both clinically and radiographically. Harris hip score (HHS) was determined before surgery and at the time of each follow-up. Presence of postoperative groin or thigh pain and squeaking were recorded. Other complications such as dislocations, periprosthetic fractures, and ceramic components fractures were diagnosed and treated in emergency. The average HHSs improved from preoperative 60.3 ± 10.7 (ranging from 29 to 76) to 91.0 ± 5.1 (ranging from 74 to 100) at the final follow-up (t = 45.064, P acetabular and stem components. No obvious osteolysis or prosthesis loosening was detected. Complications occurred in six hips (3.4%): posterior dislocation in two hips (1.1%), periprosthetic femoral fracture in one hip (0.6%), asymptomatic squeaking in two hips (1.1%), and ceramic liner fracture in one hip (0.6%). The fourth-generation COC THA showed excellent clinical results in younger active patients with no osteolysis-related prosthesis failure at a short-term follow-up study. Surgeons should still be aware of the potential risks of complications such as dislocation, periprosthetic fracture, squeaking, and ceramic components fracture.

  18. Influence of the contralateral hip state after total hip arthroplasty on patient-reported outcomes measured with the Forgotten Joint Score-12.

    Science.gov (United States)

    Matsumoto, Mikio; Baba, Tomonori; Ochi, Hironori; Ozaki, Yu; Watari, Taiji; Homma, Yasuhiro; Kaneko, Kazuo

    2017-04-25

    The purpose of this study was to examine the influence of the contralateral hip state on postoperative assessment using the Forgotten Joint Score-12 (FJS-12) in comparison with the McMaster Universities Osteoarthritis Index (WOMAC) and the Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ). One hundred and thirty-four hips underwent total hip arthroplasty (THA) between 2014 and 2015. Of these, the subjects were 106 hips with degenerative hip arthrosis as a primary disease for whom initial THA was performed on the affected side. The WOMAC and JHEQ were investigated before surgery and 1 month, 6 months, and 1 year after surgery. The FJS-12 was examined 1 month, 6 months, and 1 year after surgery. We divided the subjects into three groups based on the state of the contralateral hip, which was not surgically treated in this study: healthy (n = 43), THA (n = 31), and OA (n = 31) groups. One year after surgery, the mean FJS-12 scores in the healthy, THA, and OA groups were 69.1, 52.8, and 68.0 points, respectively. In the THA group, the score was significantly lower than in the healthy and OA group. There were no significant differences in WOMAC and JHEQ scores among the three groups. The FJS-12 score in the presence of an arthroplasty on the contralateral side was more markedly influenced by the contralateral hip state compared with that in the presence of contralateral painful OA. This result suggests that it is necessary to understand the characteristics of PROs and utilize them for post-THA assessment.

  19. Muscular strength after total hip arthroplasty

    Science.gov (United States)

    Winther, Siri B; Husby, Vigdis S; Foss, Olav A; Wik, Tina S; Svenningsen, Svein; Engdal, Monika; Haugan, Kristin; Husby, Otto S

    2016-01-01

    Background and purpose Minimizing the decrease in muscular strength after total hip arthroplasty (THA) might allow patients to recover faster. We evaluated muscular strength in patients who were operated on using 3 surgical approaches. Patients and methods In a prospective cohort study, 60 patients scheduled for primary THA were allocated to the direct lateral, posterior, or anterior approach. Leg press and abduction strength were evaluated 2 weeks or less preoperatively, 2 and 8 days postoperatively, and at 6-week and 3-month follow-up. Results Differences in maximal strength change were greatest after 2 and 8 days. The posterior and anterior approaches produced less decrease in muscular strength than the direct lateral approach. 6 weeks postoperatively, the posterior approach produced greater increase in muscular strength than the direct lateral approach, and resulted in a greater increase in abduction strength than the anterior approach. At 3-month follow-up, no statistically significant differences between the groups were found. The operated legs were 18% weaker in leg press and 15% weaker in abduction than the unoperated legs, and the results were similar between groups. Interpretation The posterior and anterior approaches appeared to have the least negative effect on abduction and leg press muscular strength in the first postoperative week; the posterior approach had the least negative effect, even up to 6 weeks postoperatively. THA patients have reduced muscle strength in the operated leg (compared to the unoperated leg) 3 months after surgery. PMID:26141371

  20. The Impact of Hypotensive Epidural Anesthesia on Distal and Proximal Tissue Perfusion in Patients Undergoing Total Hip Arthroplasty

    Science.gov (United States)

    Danninger, Thomas; Stundner, Ottokar; Ma, Yan; Bae, James J; Memtsoudis, Stavros G

    2014-01-01

    Little data exists to detail the effect of hypotensive epidural anesthesia on differential tissue oxygenation changes above and below the level of neuraxial blockade. This study was designed to investigate tissue oxygenation in a clinical setting, using non-invasive near-infrared spectroscopy. Methods Patients aged 18 to 85 years scheduled to undergo primary total hip arthroplasty were enrolled. Muscle oxygenation saturation was measured above and below the level of neuraxial blockade (deltoid and vastus lateralis muscles). Other continuously recorded parameters included cardiac output, stroke volume, heart rate, invasive mean arterial blood pressure and arterial oxygen saturation. Recordings of muscle oxygenation were compared over time separately for upper and lower extremity. Results 10 patients were enrolled. We found an intermittent and significant unadjusted decline of mean muscle oxygenation saturation in the vastus lateralis muscle during first part of the surgery (nadir 2nd quintile: 71.0% vs. 63.3%, p<0.0001). This decline was followed by a return to baseline towards the end of the surgery (71.0% vs. 69.1%, p=0.3429). Mean muscle oxygenation saturation did not change for the same period of time in the deltoid muscle. When adjusting for covariates, the changes in muscle tissue oxygenation remained significant. Conclusion These results indicate that muscle oxygenation saturation, a surrogate parameter for tissue perfusion, is decreased by hypotensive epidural anesthesia, but only within the functional limits of the neuraxial blockade. The etiology of these findings remains to be elucidated. PMID:24563810

  1. Pre-operative ambulatory measurement of asymmetric lower limb loading during walking in total hip arthroplasty patients

    NARCIS (Netherlands)

    Martínez-Ramírez, Alicia; Weenk, Dirk; Lecumberri, Pablo; Verdonschot, Nico; Pakvis, Dean; Veltink, Peter H.

    2013-01-01

    The main goal of this study was to investigate how mobility characteristics during walking, relate to gait velocity and questionnaire outcomes of patients with hip osteoarthritis in an outpatient setting. Methods 22 patients with primary osteoarthritis of the hip selected for a total hip arthroplast

  2. Thirty-five-year results after Charnley total hip arthroplasty in patients less than fifty years old. A concise follow-up of previous reports.

    Science.gov (United States)

    Warth, Lucian C; Callaghan, John J; Liu, Steve S; Klaassen, Alison L; Goetz, Devon D; Johnston, Richard C

    2014-11-05

    We report the updated results for a previously described cohort of patients who were less than fifty years old at the time of the index Charnley total hip arthroplasty with cement. The original cohort consisted of ninety-three consecutive hips in sixty-nine patients. The patients were followed for a minimum of thirty-five years after surgery or until death. At the latest follow-up evaluation, there were forty-one total hip replacements (44%) in thirty-two living patients. Thirty-four (37%) of the ninety-three total hip replacements in the original cohort had been revised or removed. Twenty acetabular (22%) and seven femoral (8%) components had been revised for aseptic loosening. Since the twenty-five-year follow-up, the average six-minute-walk distance decreased from 395 m to 171 m, and this decrease correlated with increasing comorbidity. This study demonstrates the durability of cemented total hip replacements in a young patient population. Although 63% (fifty-nine) of the ninety-three original hip replacements were functioning at the latest follow-up or at the time of death, a significant decrease in activity level was seen over time (p < 0.001). Of the forty-one original implants in the patients who were alive at the time of the thirty-five-year follow-up, only 46% (nineteen) were retained. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  3. Total bilateral hip arthroplasty in one surgical procedure

    Directory of Open Access Journals (Sweden)

    Popović Zoran

    2007-01-01

    Full Text Available Background/Aim. Primary coxarthrosis occurs often in older population. There is possibility of implanting both endoprothesis simultaneously in bilateral coxarthrosis which decreases hospitalization and reduces the expenses and possibility of complication that can occur during general anesthesia. The most serious indications for bilateral total hip arthroplasty in one procedure are younger patients with serious bilateral osteoarthrosis of the hips, without added diseases. Absolute contraindication is found in patients with persistent ductus arteriosus and septal defect. The aim of this study was to point out the possibility and advantages of a single-staged bilateral hip arthroplasty and introducing it in our orthopedic practice. Methods. The procedure was accomplished in 19 patients. The standard total hip arthroplasty surgical technique was performed, followed by the usual antibiotic and anticoagulant therapy. Results. Only one complication - acetabular part instability we recorded, followed by luxation that was surgically managed. Conclusion. This procedure can be performed routinely in selected population and should be reserved for major medical centers capable to provide adequate postoperative care.

  4. Preoperative Predictors of Ambulation Ability at Different Time Points after Total Hip Arthroplasty in Patients with Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Akiko Kamimura

    2014-01-01

    Full Text Available The aims of this study were to identify the preoperative factors influencing ambulation ability at different postoperative time points after total hip arthroplasty (THA and to examine the cutoff values of predictive preoperative factors by receiver operating characteristic (ROC curves. Forty-eight women with unilateral THA were measured for hip extensor, hip abductor, and knee extensor muscle strength in both legs; hip pain (visual analog scale, VAS; and the Timed Up and Go (TUG test pre- and postoperatively. Multiple regression analysis indicated that preoperative knee extensor strength (β=-0.379,R2=0.409 at 3 weeks, hip abductor strength (β=-0.572,R2=0.570 at 4 months, and age (β=0.758,R2= 0.561 at 7 months were strongly associated with postoperative ambulation, measured using the TUG test. Optimal preoperative cutoff values for ambulation ability were 0.56 Nm/kg for knee extensor strength, 0.24 Nm/kg for hip abductor strength, and 73 years of age. Our results suggest that preoperative factors predicting ambulation ability vary by postoperative time point. Preoperative knee extensor strength, hip abductor strength, and age were useful predictors of ambulation ability at the early, middle, and late time points, respectively, after THA.

  5. THERAPEUTIC STRATEGY IN THE REHABILITATION OF THE DYSPLASTIC HIP THROUGH ARTHROPLASTY

    Directory of Open Access Journals (Sweden)

    Liliana SAVIN

    2012-07-01

    Full Text Available Total hip arthroplasty in degenerative pathology secondary to congenital dysplasia differentiates itself amongtotal arthroplasties by the frequent technical difficulties it poses and the site where it is performed. The existence of aform of congenital dysplasia that remained untreated or insufficiently treated in childhood leads to irreversibledeformities in adulthood. Partial or total loss of joint congruence causes, in time, degenerative changes with theimpairment of hip mobility and is associated with a number of progressive deformations (limb length discrepancy,abnormal rotation, asymmetric lesions, periarticular muscle failure, which gradually reduce the quality of the patient’slife. This study aims at investigating the incidence of prosthetic hip arthroplasty for osteoarthritis secondary todysplastic hip in the total number of arthroplasties, the age when surgery is performed, the type of deformity andprosthetic components used, and the postoperative and long-term functional results. The study was conducted on 110patients who received total hip arthroplasty due to osteoarthritis secondary to hip dysplasia, between 1994 and 2011, inthe Orthopaedics Trauma Department of the Rehabilitation Hospital of Iasi, the incidence being of 3.34% of the totalnumber of arthroplasties, with a prevalence of 65% under the age of 50 years. The functional results were assessed,according to the Harris-hip-score parameters, as good or very good in proportion of 82%. The complexity of the areawhere the total hip arthroplasty is performed requires a good management consisting of thorough preoperativeplanning, determining the operatory indication, and specialized and individualized medical recovery.

  6. Total Hip Arthroplasty in Mucopolysaccharidosis Type IH

    Directory of Open Access Journals (Sweden)

    S. O'hEireamhoin

    2011-01-01

    Full Text Available Children affected by mucopolysaccharidosis (MPS type IH (Hurler Syndrome, an autosomal recessive metabolic disorder, are known to experience a range of musculoskeletal manifestations including spinal abnormalities, hand abnormalities, generalised joint stiffness, genu valgum, and hip dysplasia and avascular necrosis. Enzyme therapy, in the form of bone marrow transplantation, significantly increases life expectancy but does not prevent the development of the associated musculoskeletal disorders. We present the case of a 23-year-old woman with a diagnosis of Hurler syndrome with a satisfactory result following uncemented total hip arthroplasty.

  7. Imaging of hip arthroplasty; Bildgebung bei Hueftprothesen

    Energy Technology Data Exchange (ETDEWEB)

    Breitenseher, M.J. [Abteilung fuer Osteologie, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Klinische Abteilung fuer Radiodiagnostik chirurgischer Faecher, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Ludwig-Boltzmann-Institut fuer Radiologische Tumordiagnostik, Wien (Austria); Mayerhoefer, M. [Klinische Abteilung fuer Radiodiagnostik chirurgischer Faecher, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Gottsauner-Wolf, F. [Universitaetsklinik fuer Orthopaedie, Wien (Austria); Abteilung fuer Orthopaedie, Allgemeines oeffentliches KH, Krems (Austria); Krestan, C.; Imhof, H. [Abteilung fuer Osteologie, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Toma, C.D. [Universitaetsklinik fuer Orthopaedie, Wien (Austria)

    2002-06-01

    Hip arthroplasty has become a common and still increasing procedure for the treatment of osteoarthritis, advanced head necrosis, post-inflammatory arthritis or rheumatoid arthritis.Radiography is the most important imaging modality for monitoring the normal, asymptomatic hip arthroplasty. Radiographs are obtained at the end of a surgical treatment, to exclude complications like fracture or component misplacement. In the follow-up radiographs are used for the diagnosis of loosening and infection of the hip arthroplasty as well as soft tissue ossification. Together with the history and clinical information, the analysis of morphological findings allows to find the grade of loosening. MRI has been advocated in the diagnosis of infection, in particular in the localisation of soft tissue involvement.Imaging, especially by radiographs, is used for the evaluation of the normal and complicated follow-up of hip arthroplasty. (orig.) [German] Die Implantation einer Hueftgelenkprothese ist eine immer haeufiger verwendete medizinische Massnahme bei Erkrankungen des Hueftgelenks wie Koxarthrose, Hueftkopfnekrose, postentzuendliche Arthrose oder rheumatoide Arthritis.Von den bildgebenden Methoden ist das konventionelle Roentgen die wichtigste Untersuchung, um den normalen Behandlungsverlauf einer Hueftprothese zu monitieren. Das Roentgen kann fruehzeitige Komplikationen wie Fraktur oder Fehlposition intraoperativ oder eine Luxation postoperativ erfassen. Im laengerfristigen Verlauf ist das Roentgen zur Diagnose von Infektion, Prothesenlockerung und Weichteilverknoecherung geeignet. In Zusammenschau mit der Klinik ermoeglicht die Analyse morphologisch-radiologischer Details, die Wahrscheinlichkeit einer Lockerung abzuschaetzen. Bei Protheseninfektionen ermoeglicht die MRT die Lokalisation von Weichteilentzuendungen.Die Methoden der Bildgebung, besonders das Roentgen, haben in der Beurteilung des normalen und in der Diagnose des komplizierten Verlaufes einen hohen Stellenwert

  8. Delayed Femoral Nerve Palsy Associated with Iliopsoas Hematoma after Primary Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar

    2016-01-01

    Full Text Available Femoral nerve neuropathy after total hip arthroplasty is rare but catastrophic complication. Pain and quadriceps muscle weakness caused by this complication can significantly affect the functional outcome. Here we present a case report, describing delayed onset femoral nerve palsy associated with iliopsoas hematoma following pseudoaneurysm of a branch of profunda femoris artery after 3 months of primary total hip arthroplasty in an 80-year-old female patient with single kidney. Hip arthroplasty was done for painful primary osteoarthritis of left hip. Diagnosis of femoral nerve palsy was made by clinical examination and computed tomography imaging of pelvis. Patient was managed by surgical evacuation of hematoma and physiotherapy. The patient’s clinical symptoms were improved after surgical evacuation of hematoma. This is the first case report of its kind in English literature regarding delayed onset femoral nerve palsy after primary total hip arthroplasty due to pseudoaneurysm of a branch of profunda femoris artery without any obvious precipitating factor.

  9. Adverse effect profile comparison of pain regimens with and without intravenous acetaminophen in total hip and knee arthroplasty patients

    Science.gov (United States)

    Gallipani, Alyssa; Mathis, A Scott; Lee Ghin, Hoytin; Fahim, Germin

    2017-01-01

    Background: The use of adjunct, non-opioid agents is integral for pain control following total hip and knee arthroplasty. Literature comparing safety profiles of intravenous acetaminophen versus opioids is lacking. Objective: To determine whether there is a difference in frequency and type of adverse effects between intravenous acetaminophen–treated and non-intravenous acetaminophen–treated patients. Primary safety endpoints included any adverse effect noted in the electronic medical record post-surgically. Secondary endpoints included changes in laboratory values, vital signs, and pain scores. Methods: This is a retrospective, matched, cohort study with data collected from electronic medical records. Adverse effects were collected from progress notes, nursing notes, and post-operative notes. Mean pain score was measured by the 11-point visual analog scale over a 72-h period. Results: A total of 609 patients who underwent a total hip or knee replacement were included. In all, 406 patients were treated with intravenous acetaminophen, and 203 patients received medication management without intravenous acetaminophen. More patients treated with intravenous acetaminophen experienced an adverse effect compared to patients who did not receive intravenous acetaminophen (91.63% versus 84.73%; p = 0.012). Mean cumulative acetaminophen exposure was similar in the intravenous acetaminophen group (7704.89 ± 2558.6 versus 7260.1 ± 3016.09 mg; p = 0.07). Mean opioid use was similar in the intravenous acetaminophen group as compared to the non-intravenous acetaminophen group (209.61 ± 555.09 versus 163.89 ± 232.44 mg; p = 0.152). Significantly higher mean pain scores were found in the intravenous acetaminophen group during the 72-h post-surgery period as compared with non-intravenous acetaminophen-treated patients. Conclusion: The increased utilization of intravenous acetaminophen in multimodal pain management did not result in an improved

  10. Postoperative effects of neuromuscular exercise prior to hip or knee arthroplasty

    DEFF Research Database (Denmark)

    Villadsen, Allan; Overgaard, Søren; Holsgaard-Larsen, Anders

    2014-01-01

    OBJECTIVE: To investigate the postoperative efficacy of a supervised programme of neuromuscular exercise prior to hip or knee arthroplasty. METHODS: In this assessor-blinded randomised controlled trial, we included 165 patients scheduled for hip or knee arthroplasty due to severe osteoarthritis (OA......). An 8-week preoperative neuromuscular supervised exercise programme was delivered twice a week for 1 h as adjunct treatment to the standard arthroplasty procedure and compared with the standard arthroplasty procedure alone. The primary outcome was self-reported physical function measured...

  11. Current possibilities for hip arthroplasty,

    Directory of Open Access Journals (Sweden)

    Giancarlo Cavalli Polesello

    2014-04-01

    Full Text Available Hip arthroscopy has been popularized over the last decade and, with technical advances regarding imaging diagnostics, understanding of the physiopathology or surgical techniques, several applications have been described. Both arthroscopy for intra-articular conditions and endoscopy for extra-articular procedures can be used in diagnosing or treating different conditions. This updated article has the objective of presenting the various current possibilities for hip arthroscopy.

  12. Cost Analysis of Ceramic Heads in Primary Total Hip Arthroplasty.

    Science.gov (United States)

    Carnes, Keith J; Odum, Susan M; Troyer, Jennifer L; Fehring, Thomas K

    2016-11-02

    The advent of adverse local tissue reactions seen in metal-on-metal bearings, and the recent recognition of trunnionosis, have led many surgeons to recommend ceramic-on-polyethylene articulations for primary total hip arthroplasty. However, to our knowledge, there has been little research that has considered whether the increased cost of ceramic provides enough benefit over cobalt-chromium to justify its use. The primary purpose of this study was to compare the cost-effectiveness of ceramic-on-polyethylene implants and metal-on-polyethylene implants in patients undergoing total hip arthroplasty. Markov decision modeling was used to determine the ceramic-on-polyethylene implant revision rate necessary to be cost-effective compared with the revision rate of metal-on-polyethylene implants across a range of patient ages and implant costs. A different set of Markov models was used to estimate the national cost burden of choosing ceramic-on-polyethylene implants over metal-on-polyethylene implants for primary total hip arthroplasties. The Premier Research Database was used to identify 20,398 patients who in 2012 were ≥45 years of age and underwent a total hip arthroplasty with either a ceramic-on-polyethylene implant or a metal-on-polyethylene implant. The cost-effectiveness of ceramic heads is highly dependent on the cost differential between ceramic and metal femoral heads and the age of the patient. At a cost differential of $325, ceramic-on-polyethylene bearings are cost-effective for patients price premium for ceramic and the age of the patient. A wholesale switch to ceramic bearings regardless of age or cost differential may result in an economic burden to the health system. Economic and decision analysis, Level III. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  13. Neurovascular lesion after total hip arthroplasty in congenital hip dysplasia: Case report

    Directory of Open Access Journals (Sweden)

    Stojković-Jovanović Tatjana

    2013-01-01

    Full Text Available Introduction. Nowadays, the total hip arthroplasty is a very frequent surgical intervention. In some cases, vascular and nerve injuries may happen around the hip with total hip arthroplasty. Although they are very rare, they may be very dangerous for the patient in some cases. This paper presents a case of a female patient, in whom the nervous fibularis lesion was detected after the total hip arthroplasty, and the occlusion of the iliac femoral artery was revealed later during physical therapy. Case Report. We described a case of a 32-year-old female patient, in whom the nervous fibularis lesion was detected after the total hip arthroplasty. The patient was referred to a ward for physical therapy. On the 19th postoperative day, she felt a vigorous ache and numbness on the left operated leg during stimulation of the paretic fibular musculature. Clinically weak inguinal arterial pulse was detected. After the examination, iliac-femoral occlusion was diagnosed. The patient was referred to the vascular surgeon. In the next few months, she was treated conservatively and eventually underwent surgery. The revascularization was achieved with a satisfactory effect. A year after the total hip replacement, the patient continued with rehabilitation and physical treatment, which lasted one and a half month and had an incomplete functional result - the patient walked with a walking stick and had weak fibular musculature of a severe degree. The vascular status of the leg was good. Conclusion. In this case, neurovascular lesions led to an incomplete functional recovery of the patient and compromised the expected treatment outcome. According to the scoring system used to assess the functionality, the result was marked as poor.

  14. Computerized range of motion analysis following dual mobility total hip arthroplasty, traditional total hip arthroplasty, and hip resurfacing.

    Science.gov (United States)

    Klingenstein, Gregory G; Yeager, Alyssa M; Lipman, Joseph D; Westrich, Geoffrey H

    2013-08-01

    Newer arthroplasty designs claim to provide superior range of motion (ROM) and greater stability than their predecessors. However, there is no way to compare ROM of implant systems in an equivalent anatomical environment in a clinical setting. This study used computer-aided design to compare ROM after hip resurfacing, 28 mm THA, 36 mm THA, and anatomic dual mobility (ADM) THA in 3D models of 5 cadaver pelvises. ROM to impingement was then tested in 10 different motions and a one-way ANOVA was used to compare results. The hip resurfacing resulted in restricted ROM compared to the other 3 models in all motions except adduction. The ADM, 36 mm, and 28 mm THA resulted in similar ROM. Dual mobility constructs provide comparable ROM in patients where large head THA is not appropriate.

  15. International metal-on-metal multidisciplinary teams: do we manage patients with metal-on-metal hip arthroplasty in the same way? An analysis from the International Specialist Centre Collaboration on MOM Hips (ISCCoMH).

    Science.gov (United States)

    Berber, R; Skinner, J; Board, T; Kendoff, D; Eskelinen, A; Kwon, Y-M; Padgett, D E; Hart, A

    2016-02-01

    There are many guidelines that help direct the management of patients with metal-on-metal (MOM) hip arthroplasties. We have undertaken a study to compare the management of patients with MOM hip arthroplasties in different countries. Six international tertiary referral orthopaedic centres were invited to participate by organising a multi-disciplinary team (MDT) meeting, consisting of two or more revision hip arthroplasty surgeons and a musculoskeletal radiologist. A full clinical dataset including history, blood tests and imaging for ten patients was sent to each unit, for discussion and treatment planning. Differences in the interpretation of findings, management decisions and rationale for decisions were compared using quantitative and qualitative methods. Overall agreement between the orthopaedic centres and the recommended treatment plans for the ten patients with MOM hip implants was moderate (kappa = 0.6). Full agreement was seen in a third of cases, however split decisions were also seen in a third of cases. Units differed in their interpretation of the significance of the investigation findings and put varying emphasis on serial changes, in the presence of symptoms. In conclusion, the management of raised or rising blood metal ions, cystic pseudotumours and peri-acetabular osteolysis led to inconsistency in the agreement between centres. Coordinated international guidance and MDT panel discussions are recommended to improve consensus in decision making. A lack of evidence and the subsequent variation in regulator guidance leads to differences in opinions, the clinical impact of which can be reduced through a multi-disciplinary team approach to managing patients with MOM hip implants. Cite this article: Bone Joint J 2016;98-B:179-86. ©2016 The British Editorial Society of Bone & Joint Surgery.

  16. [Modern tribology in total hip arthroplasty: pros and cons].

    Science.gov (United States)

    Gómez-García, F

    2014-01-01

    The wear products and adverse reactions that occur on bearing surfaces represent one of the greatest challenges in prosthetic replacements, as the latter experience increasing demands due to the large number of young and older adult patients that have a long life expectancy and remarkable activity. The purpose of this review is to analyze the pros and cons of the new advances in the bearing components of the articular surfaces of current total hip arthroplasties. We also discuss the strategies used historically, their problems, results and the surgeon's role in prescribing the tribologic couple that best fits each patient's needs. We conclude with practical recommendations for the prescription and management of the latest articular couples for total hip arthroplasty.

  17. [Revision total hip arthroplasty using a cementless prosthesis].

    Science.gov (United States)

    Jiang, Qing; Xu, Zhi-hong; Chen, Dong-yang; Shi, Dong-quan; Qin, Jiang-hui; Dai, Jin; Weng, Wen-jie; Yuan, Tao

    2012-05-01

    To assess the operative technique and results with the usage of cementless prosthesis in hip revision. Retrospective study was done on revision of total hip arthroplasty with cementless prosthesis in 72 patients (41 males and 31 females) with an average age of 65.7 years (28-82 years) from January 2004 to December 2009. The reason for revision was 2 infection, 54 aseptic loosening, 4 periprosthetic fractures, 5 fracture of femoral stems and 7 cases of acetabular abrasion after hemi-arthroplasty. The operation time, bleeding loss, complications of infection, dislocation, periprosthetic fractures and loosening were evaluated. The Harris score were used for hip function evaluation. The average operation time was (146±47) minutes (70-280 minutes) and bleeding loss during the operation was (970±540) ml (200-2500 ml). Bacterium cultivation during operation demonstrated infection in 2 patients. Bone windows at the lateral femoral were opened in 4 patients and extend trochanteric osteotomy was done in 7 patients. Fracture of the proximal femur occurred in 8 cases. Twenty-nine patients were treated with bone graft including 18 autografts and 11 allografts. Sixty-seven patients were followed up for an average time of 66 months (20-92 months). Additional revisions were performed in 3 cases including 2 dislocations and 1 infection. There were no death, no damage of major blood vessels and nerves. The bone graft healed during 3-5 months. The survival rates of the femoral prosthesis and the acetabulum prostheses were 95.5% and 98.4%. The mean Harris score was 86±8 (55-95 points). Osteolysis were seen in 13 hips but migration was seen in only 1 patient. The cementless prosthesis is useful in revision total hip arthroplasty and the perfect clinical results are related to the reliable primary fixation.

  18. Cementless revision for infection following total hip arthroplasty.

    Science.gov (United States)

    Mitchell, Philip A; Masri, Bassam A; Garbuz, Donald S; Greidanus, Nelson V; Duncan, Clive P

    2003-01-01

    Eradication of chronic infection complicating total hip arthroplasty requires removal of all infected, devitalized and foreign tissue, including the arthroplasty components. Reimplantation into a sterile bed is the goal of treatment in most patients and successful reimplantation yields better functional results than excision arthroplasty. Reimplantation may be performed at the same stage as débridement as part of a single-stage procedure, using cemented components with antibiotic-loaded cement. Alternatively, a two-stage procedure may be performed so that the débridement and reimplantation are separated by a period of antibiotic delivery, both locally and systemically. The results of these treatment regimens and the rationale for cementless reconstruction at the second stage of a two-stage treatment protocol are important considerations in the treatment of periprosthetic infection.

  19. Total hip arthroplasty with femoral subtrochanteric osteotomy after Schanz osteotomy.

    Science.gov (United States)

    Sonohata, Motoki; Kitajima, Masaru; Kawano, Shunsuke; Tanaka, Riki; Mawatari, Masaaki

    2016-07-01

    Schanz osteotomy is one of the options for the management of hip instability caused by congenital or septic arthritis. Following Schanz osteotomy, there is risk of hip pain secondary to hip arthritis. It may be necessary to perform subtrochanteric femoral osteotomy in conjunction with total hip arthroplasty (THA). This study evaluates the outcomes and complications associated with THA. We performed 36 THA after Schanz osteotomy. Patients were divided into three groups: (1) successful Schanz osteotomy, (2) highly dislocated hip with contact between the femoral head and pelvis, and (3) completely dislocated hip without contact between the femur and pelvis. Clinical and radiological evaluations were completed for each group. In all three groups, hip function improved significantly (p osteotomy after Schanz osteotomy. However, this procedure is a technically demanding treatment option, and there were characteristic complications intra and after surgery. Therefore, surgeons should treat hip osteoarthritis after Schanz operation with utmost care, especially completely dislocated hip. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  20. Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    van Raaij Jos JAM

    2008-10-01

    Full Text Available Abstract Background Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentrations. The objective of this study is to compare two cementless total hip arthroplasties: a conventional 28 mm metal-on-polyethylene articulation and a large head metal-on-metal articulation. We hypothesize that the latter arthroplasties show less bone density loss and higher serum metal ion concentrations. We expect equal functional scores, greater range of motion, fewer dislocations, fewer periprosthetic radiolucencies and increased prosthetic survival with the metal-on-metal articulation. Methods A randomized controlled trial will be conducted. Patients to be included suffer from non-inflammatory degenerative joint disease of the hip, are aged between 18 and 80 and are admitted for primary cementless unilateral total hip arthroplasty. Patients in the metal-on-metal group will receive a cementless titanium alloy acetabular component with a cobalt-chromium liner and a cobalt-chromium femoral head varying from 38 to 60 mm. Patients in the metal-on-polyethylene group will receive a cementless titanium alloy acetabular component with a polyethylene liner and a 28 mm cobalt-chromium femoral head. We will assess acetabular bone mineral density by dual energy x-ray absorptiometry (DEXA, serum ion concentrations of cobalt, chromium and titanium, self reported functional status (Oxford hip score, physician reported functional status and range of motion (Harris hip score, number of dislocations and prosthetic survival. Measurements will take place preoperatively, perioperatively, and postoperatively (6 weeks, 1 year, 5 years and 10 years. Discussion

  1. Internal iliac artery pseudoaneurysm in primary total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Sanjay Agarwala

    2016-01-01

    Full Text Available Vascular injury is one of the rare complications of primary total hip arthroplasty (THA. We report an unusual case of lobulated pseudoaneurysm arising from one of the branches of the left internal iliac artery during acetabulum preparation in THA, which was successfully treated with coil embolization and multidisciplinary care. After 6 years follow up, patient did not have any symptoms related to the hip replacement. We recommend that surgeons should be extremely cautious while drilling medial wall of the acetabulum for depth assessment. Aggressive multidisciplinary approach, including possible support from an interventional radiologist is required for the treatment of such vascular injuries.

  2. Chronic pain following total hip arthroplasty: a nationwide questionnaire study

    DEFF Research Database (Denmark)

    Nikolajsen, Lone; Brandsborg, Birgitte; Lucht, Ulf;

    2006-01-01

    BACKGROUND: Chronic post-operative pain is a well-recognized problem after various types of surgery, but little is known about chronic pain after orthopedic surgery. Severe pre-operative pain is the primary indication for total hip arthroplasty (THA). Therefore, we examined the prevalence...... was 93.6%. Two hundred and ninety-four patients (28.1%) had chronic ipsilateral hip pain at the time of completion of the questionnaire, and pain limited daily activities to a moderate, severe or very severe degree in 12.1%. The chronic pain state was related to the recalled intensity of early post...

  3. The strength and function of hip abductors following anterolateral minimally invasive total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Tan Jixiang

    2014-04-01

    Full Text Available Objective: To analyze the extent of postoperative hip abductor insufficiency in primary total hip arthroplasty (THA patients undergoing anterolateral minimally invasive (ALMI approach, and to investigate whether the clinical outcomes are more favorable in femoral neck fracture (FNF patients than in non-femoral neck fracture (nFNF patients. Methods:A total of 48 patients were enrolled in this study. Each patient underwent a clinical examination preoperatively and 6, 12, 24 and 48 weeks postoperatively. The abductor torque, Trendelenburg's sign, gait velocity, Harris hip score, Oxford hip score, Westren Ontario and McMaster Universities (WOMAC score and visual analog scale pain score were recorded. Statistical evaluation was performed with SPSS software version 18.0. The significance level was set at P<0.05. Results:The abductor torque of the operated hip and the recovery ratio showed a gradual improving tendency from 6 weeks postoperatively until the last follow-up. Gait velocity, Harris hip score, Oxford hip score and WOMAC score improved significantly after the operation until 24 weeks postoperatively. In the FNF group, the abductor torque of the operated side and the recovery ratio were significantly higher than in nFNF group at 6 weeks postoperatively, however, as time passed, this trend tended to disappear. Conclusion:This study demonstrates that patients can obtain good abductor strength and function in the early postoperative period and the hip abductor function of patients who suffer from hip osteoarthritis, rheumatoid arthritis, avascular necrosis of the femoral head could be significantly improved following ALMI THA. Key words: Arthroplasty, replacement, hip; Surgical procedures, minimally invasive; Recovery of function

  4. Conventional Versus Cross-Linked Polyethylene for Total Hip Arthroplasty.

    Science.gov (United States)

    Surace, Michele F; Monestier, Luca; Vulcano, Ettore; Harwin, Steven F; Cherubino, Paolo

    2015-09-01

    The clinical and radiographic outcomes of 88 patients who underwent primary total hip arthroplasty with either conventional polyethylene or cross-linked polyethylene (XLPE) from the same manufacturer were compared. There were no significant differences between the 2 subpopulations regarding average age, gender, side affected, or prosthetic stem and cup size. The average follow-up was 104 months (range, 55 to 131 months). To the authors' knowledge, this is the longest follow-up for this particular insert. Clinical and radiographic evaluations were performed at 1, 3, 6, and 12 months and then annually. Results showed that XLPE has a significantly greater wear reduction than that of standard polyethylene in primary total hip arthroplasty. At the longest available follow-up for these specific inserts, XLPE proved to be effective in reducing wear.

  5. Can Optimism, Pessimism, Hope, Treatment Credibility and Treatment Expectancy Be Distinguished in Patients Undergoing Total Hip and Total Knee Arthroplasty?

    Science.gov (United States)

    Haanstra, Tsjitske M; Tilbury, Claire; Kamper, Steven J; Tordoir, Rutger L; Vliet Vlieland, Thea P M; Nelissen, Rob G H H; Cuijpers, Pim; de Vet, Henrica C W; Dekker, Joost; Knol, Dirk L; Ostelo, Raymond W

    2015-01-01

    The constructs optimism, pessimism, hope, treatment credibility and treatment expectancy are associated with outcomes of medical treatment. While these constructs are grounded in different theoretical models, they nonetheless show some conceptual overlap. The purpose of this study was to examine whether currently available measurement instruments for these constructs capture the conceptual differences between these constructs within a treatment setting. Patients undergoing Total Hip and Total Knee Arthroplasty (THA and TKA) (Total N = 361; 182 THA; 179 TKA), completed the Life Orientation Test-Revised for optimism and pessimism, the Hope Scale, the Credibility Expectancy Questionnaire for treatment credibility and treatment expectancy. Confirmatory factor analysis was used to examine whether the instruments measure distinct constructs. Four theory-driven models with one, two, four and five latent factors were evaluated using multiple fit indices and Δχ2 tests, followed by some posthoc models. The results of the theory driven confirmatory factor analysis showed that a five factor model in which all constructs loaded on separate factors yielded the most optimal and satisfactory fit. Posthoc, a bifactor model in which (besides the 5 separate factors) a general factor is hypothesized accounting for the commonality of the items showed a significantly better fit than the five factor model. All specific factors, except for the hope factor, showed to explain a substantial amount of variance beyond the general factor. Based on our primary analyses we conclude that optimism, pessimism, hope, treatment credibility and treatment expectancy are distinguishable in THA and TKA patients. Postdoc, we determined that all constructs, except hope, showed substantial specific variance, while also sharing some general variance.

  6. Transfusion practice in hip arthroplasty - a nationwide study

    DEFF Research Database (Denmark)

    Jans, Øivind; Kehlet, H; Hussain, Zubair Butt;

    2011-01-01

    thirty-two THA patients and 1132 RTHA patients were included for analysis of which 1674 (24%) THA and 689 (61%) RTHA patients received RBC transfusion. Of these, 47% of THA and 73% of RTHA patients received transfusion on the day of surgery. Transfusion rates between centres varied from 7 to 71......% and between 26 and 85% in THA and RTHA patients, respectively. Patients receiving RBC transfusion had longer length of stay and for THA patients an increased odds-ratio (5·5) of death within 90 days. Conclusion Despite established guidelines, RBC transfusion practice in hip arthroplasty remains highly...

  7. [Value of preoperative planning in total hip arthroplasty].

    Science.gov (United States)

    De Thomasson, E; Mazel, C; Guingand, O; Terracher, R

    2002-05-01

    Preoperative planning enables an assessment of the size of the implants needed before total hip replacement. Eggli and Müller demonstrated the reproduciblity of preoperative planning but did not evaluate its contribution to reducing limb length discrepancy. As femur lateralization and the position of the prosthetic center of rotation affect joint mechanics, it would be useful to assess their contribution to the efficacy of preoperative planning. We reviewed the files of 57 patients who underwent total hip arthroplasty for primary joint degeneration or necrosis limited to one hip. The healthy hip served as a control. The surgical plan was elaborated from the preoperative pelvis x-rays (AP and lateral views) and anatomic measurements on films obtained three months postoperatively. In 49 cases, preoperative planning predicted a restoration of the normal anatomy of the operated hip (center of rotation, femur lateralization, length of the operated limb). This objective was achieved in only 22.5% of the cases. Femur lateralization was the most difficult objective to achieve (59.2%). Equal limb length and good position of the center of rotation was achieved in 70% of the cases. For eight patients (14%) preoperative planning was not satisfactory, the implant offset not being adapted to the patient's anatomy. There are limits to preoperative planning, particularly for restitution of adequate femur lateralization. This difficulty appears to be related to three factors: inadequate adaptation of the implant to hip anatomy (14% of the cases in our experience), stiff rotation in degenerative hips inhibiting proper assessment of the length of the femoral neck, and relative imprecision of operative evaluation of femoral anteversion affecting femur lateralization and the level of the femoral cut. Although imperfect, preoperative planning is, in our opinion, essential before total hip arthroplasty in order to avoid major positioning errors and operative difficulties.

  8. Does Hepatitis C Affect the Clinical and Patient-Reported Outcomes of Primary Total Hip Arthroplasty at Midterm Follow-Up?

    Science.gov (United States)

    Issa, Kimona; Pierce, Todd P; Harwin, Steven F; Scillia, Anthony J; McInerney, Vincent K; Mont, Michael A

    2017-09-01

    It is estimated that 3%-6% of orthopedic patients, many of whom may undergo lower extremity total joint arthroplasty, are infected with hepatitis C. The purpose of this study was to assess the outcomes of patients with hepatitis C who undergo total hip arthroplasty (THA) in comparison with a matched control cohort in terms of (1) patient-reported outcomes, (2) implant survivorship, and (3) complications. Fifty-four hips in 49 hepatitis C-infected patients who underwent a primary THA between 2002 and 2011 were reviewed. This included 10 women and 39 men who had a mean age of 57 years and a mean 6.5-year follow-up. These patients were matched to 163 THAs (148 patients) who did not have this disease and underwent a THA during the same period. We compared implant survivorship, complication rates, Harris hip scores, and University of California, Los Angeles, activity scores. Radiographs were evaluated for loosening, fracture, malalignment, and osteolysis. The implant survivorship in the hepatitis C-infected patients and comparison group was 96.2% and 98.7%, respectively. The risk of revision surgery in the hepatitis C cohort was 3-fold higher than the comparison group; however, this difference was not significant (P = .26). The hepatitis C-infected cohort had a higher risk of surgical complications (odds ratio = 6.5; P = .034). There were no differences in postoperative Harris hip scores or University of California, Los Angeles, activity scores between the cohorts. Hepatitis C patients can achieve good implant survivorship and clinical outcomes after THA. However, these patients may be at an increased risk for surgical complications and revision rate. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. The rehabilitation management after hip arthroplasty: a case report

    Directory of Open Access Journals (Sweden)

    Adina BURCHICI

    2017-03-01

    Full Text Available Aim: In this paper we describe the physical therapy management of a 64-year-old female following a bilateral hip arthroplasty. Method: The patient featured in this study, after the surgical intervention had undergone specific recovery treatment consisting of: posture techniques, static (isometric contractions and dynamic kinetic techniques (passive motion, passive-actives, actives, actives with resistance, massage, respiratory gymnastics and reeducation of walking. Results: At the end of the rehabilitation program, hip muscular strength and joint range of motion were improved significantly. The Harris hip score was significantly improved, in comparison to the preoperative one. Conclusion: This case illustrates the importance of the rehabilitation management after bilateral hip replacement.

  10. Bilateral hip arthroplasty: is 1-week staging the optimum strategy?

    Directory of Open Access Journals (Sweden)

    Willis-Owen Charles A

    2010-11-01

    Full Text Available Abstract Seventy-nine patients underwent bilateral hip arthroplasty staged either at 1 week (Group 1 or after greater intervals (as suggested by the patients, mean 44 weeks, range 16-88 weeks (Group 2, over a five year period at one Institution. Sixty-eight patients (29 bilateral hip resurfacings and 39 total hip replacements completed questionnaires regarding their post-operative recovery, complications and overall satisfaction with the staging of their surgery. There was no significant age or ASA grade difference between the patient groups. Complication rates in the two groups were similar and overall satisfaction rates were 84% in Group 1 (n = 32 and 89% in Group 2 (n = 36. Cumulative hospital lengths of stay were significantly longer in Group 1 patients (11.9 days vs 9.1 days(p The mean time to return to part-time work was 16.4 weeks for Group 1, and a cumulative 17.2 weeks (8.8 and 8.4 weeks for Group 2. The time to return to full-time work was significantly shorter for Group 1 patients (21.0 weeks, compared with a cumulative 29.7 weeks for Group 2(p Hip resurfacing patients in Group 2 had significantly shorter durations of postoperative pain and were able to return to part-time and full time work sooner than total hip arthroplasty patients. There was a general trend towards a faster recovery and resumption of normal activities following the second operation in Group 2 patients, compared with the first operation. Bilateral hip arthroplasty staged at a 1-week interval resulted in an earlier resolution of hip pain, and an earlier return to full-time work (particularly following total hip replacement surgery, with high levels of patient satisfaction and no increased risk in complications; however the hospital length of stay was significantly longer. The decision for the timing of staged bilateral surgery should be made in conjunction with the patient, making adjustments to accommodate their occupational needs and functional demands.

  11. Total hip arthroplasty in a patient with arthrogryphosis and an ipsilateral above knee amputation.

    LENUS (Irish Health Repository)

    Leonard, Michael

    2010-10-01

    The authors present the case of a young man with arthrogryphosis multiplex congenita and an above knee amputation who underwent an ipsilateral total hip replacement. The unique aspects of the case and technical difficulties are highlighted. Follow-up at five years revealed an excellent clinical and radiological outcome.

  12. Failure of total hip arthroplasty with Boneloc bone cement.

    Science.gov (United States)

    Gebuhr, P; Stentzer, K; Thomsen, F; Levi, N

    2000-12-01

    Early failure of Boneloc cemented total hip arthroplasty is well documented. However, information regarding the long term prognosis is scanty. The aim of this study was therefore to assess the long term failure rate of total hip replacement with Boneloc bone cement. Between January 1991 and March 1992, Boneloc bone cement (Polymers Recontructive A/S, Farum, Denmark) was used in 42 consecutive total hip replacements in 42 patients. The average age of the patients was 75 years. There were 25 women and 17 men. The diagnosis at operation was osteoarthritis in all cases. A cemented Muller Taperloc femoral stem was used with a cemented Muller acetabular cup (Biomet, Warsaw, USA). The follow-up time was 9 years. All patients underwent radiographic control the first postoperative year and annually after 1995. To date 21 patients have been revised for aseptic loosening at a mean of 5 years (range: one year to 8 years). Three other patients have definite radiographic evidence of loosening. The overall failure rate is therefore 24/42 = 57%. Our results confirm the previously reported poor results of Boneloc bone cement for hip arthroplasty and support the recommendation of indefinite follow-up for surviving prostheses. New prosthesis designs and new cements should have documentation, including laboratory tests and randomized clinical studies with radiostereometric evaluation. However, the ethical responsibility rests heavily on the shoulders of the clinician to make a correct analysis of the need for a new product before he begins to use it.

  13. Acute-onset severe gastrointestinal tract hemorrhage in a postoperative patient taking rivaroxaban after total hip arthroplasty: a case report

    LENUS (Irish Health Repository)

    Boland, Michael

    2012-05-14

    AbstractIntroductionRivaroxaban, a new oral anticoagulant, is currently licensed for use in patients undergoing orthopedic surgery. It is more efficacious than other anticoagulants such as low molecular weight heparin and does not require daily monitoring. It has also been shown to be efficacious in patients with venous thromboembolism and acute coronary syndrome. Although hemorrhage is a known side effect of this new anticoagulant, we could find no case reports in the literature of patients suffering severe hemorrhage whilst taking rivaroxaban. Thus, we describe the first case of potentially fatal hemorrhage in a patient taking rivaroxaban.Case presentationWe report the case of a 58-year-old Caucasian man with acute-onset severe per rectal bleeding who had undergone total hip arthroplasty four weeks prior to the onset of symptoms and was taking rivaroxaban in the postoperative period. Rivaroxaban was discontinued immediately but, having required nine units of packed red blood cells in a peripheral hospital due to a rapidly decreasing hemoglobin level, our patient was transferred to our tertiary referral center where he required a further eight units of packed red blood cells over a 48-hour period to manage his ongoing hemorrhage and maintain hemodynamic stability. No source of bleeding was found on computed tomography angiography and our patient’s condition improved over the following 48 hours with cessation of the hemorrhage. Our patient was discharged home well several days later. A follow-up colonoscopy one week after his discharge was normal.ConclusionAlthough advantageous with regard to its oral availability and ongoing use without the need for daily monitoring, rivaroxaban does not come without rare but severe side effects. When severe per rectal bleeding occurs in a patient taking rivaroxaban, discontinuation of the offending agent and aggressive hematological replacement are the mainstays of treatment, especially when no source of bleeding can be found

  14. Heterotopic ossification after hip arthroplasty: a randomized double-blind multicenter study tenoxicam in 147 hips

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Sletgård, J; Dalsgård, J;

    1996-01-01

    147 patients due to have a cemented total hip arthroplasty were randomized to 4 groups. They received either tenoxicam 20 mg or 40 mg, or placebo, for 5 days or morphine on the day of operation and placebo for 4 days. During the first 5 days 14 patients were excluded. The patients were followed...... for 1 year, during which another 10 patients were excluded. At follow-up, significantly fewer patients had heterotopic ossifications in the tenoxicam groups than in the placebo and morphine groups. There was no significant difference between the 2 tenoxicam-treated groups, and we therefore conclude...... that tenoxicam 20 mg for 5 days postoperatively can reduce heterotopic ossification after cemented total hip arthroplasty....

  15. Cardiac transplant due to metal toxicity associated with hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Sheldon Moniz, MBBS (UWA

    2017-09-01

    Full Text Available Concerns regarding metal-on-metal (MoM bearing couples in total hip arthroplasty are well documented in the literature with cobalt (Co and chromium (Cr toxicity causing a range of both local and systemic adverse reactions. We describe the case of a patient undergoing cardiac transplantation as a direct result of Co and Cr toxicity following a MoM hip replacement. Poor implant positioning led to catastrophic wear generating abundant wear particles leading to Co and Cr toxicity, metallosis, bony destruction, elevated metal ion levels, and adverse biological responses. Systemic symptoms continued for 3 years following cardiac transplantation with resolution only after revision hip arthroplasty. There was no realization in the initial cardiac assessment and subsequent transplant workup that the hip replacement was the likely cause of the cardiac failure, and the hip replacement was not recognized as the cause until years after the heart transplant. This case highlights the need for clinicians to be aware of systemic MoM complications as well as the importance of positioning when using these prostheses.

  16. Digital versus analogue preoperative planning of total hip arthroplasties - A randomized clinical trial of 210 total hip arthroplasties

    NARCIS (Netherlands)

    The, Bertram; Verdonschot, Nico; van Horn, Jim R.; van Ooijen, Peter M. A.; Diercks, Ron L.

    2007-01-01

    The objective of this randomized clinical trial was to compare the clinical and technical results of digital preoperative planning for primary total hip arthroplasties with analogue planning. Two hundred and ten total hip arthroplasties were randomized. All plans were constructed on standardized rad

  17. Estimation of dislocation after total hip arthroplasty by 4-dimensional.

    Science.gov (United States)

    Otake, Yoshito; Suzuki, Naoki; Hattori, Asaki; Miki, Hidenobu; Yamamura, Mitsuyoshi; Nakamura, Nobuo; Sugano, Nobuhiko; Yonenobu, Kazuo; Ochi, Takahiro

    2005-01-01

    We constructed a 4-dimensional musculoskeletal model for patients who have undergone total hip arthroplasty (THA), which aimed to simulate the movement of the patient's inner body structure and estimate the complications that can arise with THA. The model reflects patient-specific characteristics of the bone geometry, implant alignment and hip movement. In order to estimate the direction of the muscle force and the length of the muscles, we developed a string-type muscle model that represents the route of the muscles. The strings expand and contract according to the movement of the origin and insertion location of the muscle. We developed models for the seven muscles related to movement of the hip joint. By using this model, clinicians will be able to predict the possibility of dislocation or recognize the actual causes of dislocation, as well as any possible influences the muscle may have on dislocation.

  18. Metal ion levels and functional results following resurfacing hip arthroplasty versus conventional small-diameter metal-on-metal total hip arthroplasty; a 3 to 5year follow-up of a randomized controlled trial

    NARCIS (Netherlands)

    Bisseling, P.; Smolders, J.M.; Hol, A.; Susante, J.L.C. van

    2015-01-01

    We present an update of a randomized controlled trial on 71 patients (<65 years) who received either a resurfacing hip arthroplasty (RHA) (n=38) or cementless 28-mm metal-on-metal (MoM) total hip arthroplasty (THA) (n=33). Metal ion levels and functional outcome scores were analyzed with a mean f

  19. Eradication of multidrug-resistant Acinetobacter baumannii in a female patient with total hip arthroplasty, with debridement and retention: a case report

    Directory of Open Access Journals (Sweden)

    Beieler Alison M

    2009-02-01

    Full Text Available Abstract Introduction Multidrug-resistant Acinetobacter baumannii has become a significant cause of healthcare-associated infections, but few reports have addressed Acinetobacter baumannii infections associated with orthopedic devices. The current recommended treatment for complicated infections due to orthopedic devices, including resistant gram-negative rods, consists of antimicrobial therapy with debridement and removal of implants. Case presentation The patient, a 47-year-old woman, had previously had a prior total hip arthroplasty at 16 years of age for a complex femoral neck fracture, and multiple subsequent revisions. This time, she underwent a fifth revision secondary to pain. Surgery was complicated by hypotension resulting in transfer to the intensive care unit and prolonged respiratory failure. She received peri-operative cefazolin but postoperatively developed surgical wound drainage requiring debridement of a hematoma. Cultures of this grew ampicillin-sensitive Enterococcus and Acinetobacter baumannii (sensitive only to amikacin and imipenem. The patient was started on imipenem. Removal of the total hip arthroplasty was not recommended because of the recent surgical complications, and the patient was eventually discharged home. She was seen weekly for laboratory tests and examinations and, after 4 months of therapy, the imipenem was discontinued. She did well clinically for 7 months before recurrent pain led to removal of the total hip arthroplasty. Intra-operative cultures grew ampicillin-sensitive Enterococcus and coagulase-negative Staphylococcus but no multidrug-resistant Acinetobacter baumannii. The patient received ampicillin for 8 weeks and had not had recurrent infection at the time of writing, 37 months after discontinuing imipenem. Conclusion We describe the successful treatment of an acute infection from multidrug-resistant Acinetobacter baumannii with debridement and retention of the total hip arthroplasty, using

  20. PRIMARY CEMENTLESS TOTAL HIP ARTHROPLASTY IN ANKYLOSING SPONDYLITIS

    Directory of Open Access Journals (Sweden)

    Nageshwara Rao

    2015-12-01

    Full Text Available INTRODUCTION Ankylosing Spondylitis (AS, family of Spondyloarthritides (SpAs, is a chronic inflammatory disease affecting the axial skeleton, the entheses and occasionally the peripheral joints. The shoulders and hips are considered axial joints and involvement occurs in up to 50% of patients and is more common than involvement of the more distal joints. Aim of our study is to evaluate outcome of Cementless Total Hip Arthroplasty (THA in ankylosing spondylitis. MATERIALS AND METHODS We prospectively and retrospectively reviewed 27 hips in 20 patients who underwent cementless THA between 2007-2013. Mean age of patient was 31.5 years. We analysed demographic data, preoperative deformity, Harris Hip Score, ambulatory status, need for walking aids. RESULTS All patients experienced significant improvement in function, range of motion, posture and ambulation. Postoperative Harris Hip Score improved from 18.95 to 89.35; 90% are completely pain free, 5% have occasional discomfort and 5% have mild-to-moderate pain. CONCLUSION Cementless THA for deformed hips in young patients with AS is worthwhile surgical intervention, as it increases the mobility of the patient, improves the ability to sit comfortably, decrases the morbidity of the disease. However, the technically demanding nature of the procedure should not be underestimated.

  1. Postoperative pain treatment after total hip arthroplasty

    DEFF Research Database (Denmark)

    Højer Karlsen, Anders Peder; Geisler, Anja; Petersen, Pernille Lykke

    2015-01-01

    of this systematic review was to document the procedure-specific evidence for analgesic interventions after total hip arthroplasty (THA). This PRISMA-compliant and PROSPERO-registered review includes randomized placebo-controlled trials (RCTs) of medication-based analgesic interventions after THA. Endpoints were......, and lumbar plexus block reduced nausea and pruritus. The GRADE-rated quality of evidence ranged from low to very low throughout the analyses. This review demonstrated, that some analgesic interventions may have the capacity to reduce mean opioid requirements and/or mean pain intensity compared with controls...

  2. Combined Anterior and Posterior Approach in Total Hip Arthroplasty for Crowe IV Dysplasia or Ankylosed Hips.

    Science.gov (United States)

    Lee, Young-Kyun; Kim, Ki-Choul; Ha, Yong-chan; Koo, Kyung-Hoi

    2015-05-01

    We evaluated 70 patients (71 hips) who underwent complex total hip arthroplasty (THA) through the combined anterior and posterior approach. Sixty-five patients (32 dislocated hips and 34 ankylosed hips) were followed-up at a minimum of 3 years (median, 6 years; range, 3-10 years). Seven patients (10.6%), who had transient paresthesia on the anterior thigh, recovered within 3 months. All patients had a good clinical outcome in terms of range of motion, pain and recovery of walking. At the latest follow-up, all prostheses had bone-ingrown stability without any detectable wear or osteolysis. The combined approach allows an excellent exposure of the acetabulum for accurate cup alignment, leg lengthening and mobilization of joint in complex THA without trochanteric osteotomy, excessive abductor release and femoral shortening osteotomy. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Revision Total Hip Arthroplasty Using a Modular Tapered Stem With Distal Fixation Good Short-Term Results in 125 Revisions

    DEFF Research Database (Denmark)

    Ovesen, Ole; Emmeluth, Claus; Hofbauer, Christian;

    2009-01-01

    After 2 to 7 years we reviewed 125 prosthetic hip arthroplasty stem revisions using a modular tapered stem with distal fixation. Median age of these patients was 68 (33-92) years. Baseline and follow-up data were registered prospectively according to the Danish Hip Arthroplasty Registry. Survival...

  4. Assessment of asymmetric leg loading before and after total hip arthroplasty using instrumented shoes

    NARCIS (Netherlands)

    Martinez-Ramirez, A.; Weenk, D.; Lecumberri, P.; Verdonschot, N.J.J.; Pakvis, D.; Veltink, P.H.

    2014-01-01

    BACKGROUND: Total hip arthroplasty is a successful surgical treatment in patients with osteoarthritis of the hip. Different questionnaires are used by the clinicians to assess functional capacity and the patient's pain, despite these questionnaires are known to be subjective. Furthermore, many studi

  5. Treatment of displaced neck fractures of the femur with total hip arthroplasty.

    Science.gov (United States)

    Rudelli, Sergio; Viriato, Sergio P; Meireles, Tadeu L O; Frederico, Tiago N

    2012-02-01

    We report our experience in unstable fractures of the femoral neck in a consecutive series of patients who underwent total hip arthroplasty. Over a period of 12 years, 88 patients were treated with a cemented total hip arthroplasty; 3 patients were lost to follow-up, leaving 86 fractures (85 patients) for retrospective analysis. Seven patients had dislocations, all but 1 of which were treated successfully without reoperation. Four patients required reoperation in the same hip undergoing arthroplasty. There was a graded increase in mortality rates across the continuum of risk groups at the time of surgery. The low incidence (4.6%) of a second procedure on the hip repaired initially, as well as low mortality rates, makes this treatment strategy quite satisfactory.

  6. Short Operative Duration and Surgical Site Infection Risk in Hip and Knee Arthroplasty Procedures.

    Science.gov (United States)

    Dicks, Kristen V; Baker, Arthur W; Durkin, Michael J; Anderson, Deverick J; Moehring, Rebekah W; Chen, Luke F; Sexton, Daniel J; Weber, David J; Lewis, Sarah S

    2015-12-01

    To determine the association (1) between shorter operative duration and surgical site infection (SSI) and (2) between surgeon median operative duration and SSI risk among first-time hip and knee arthroplasties. Retrospective cohort study A total of 43 community hospitals located in the southeastern United States. Adults who developed SSIs according to National Healthcare Safety Network criteria within 365 days of first-time knee or hip arthroplasties performed between January 1, 2008 and December 31, 2012. Log-binomial regression models estimated the association (1) between operative duration and SSI outcome and (2) between surgeon median operative duration and SSI outcome. Hip and knee arthroplasties were evaluated in separate models. Each model was adjusted for American Society of Anesthesiology score and patient age. A total of 25,531 hip arthroplasties and 42,187 knee arthroplasties were included in the study. The risk of SSI in knee arthroplasties with an operative duration shorter than the 25th percentile was 0.40 times the risk of SSI in knee arthroplasties with an operative duration between the 25th and 75th percentile (risk ratio [RR], 0.40; 95% confidence interval [CI], 0.38-0.56; P<.01). Short operative duration did not demonstrate significant association with SSI for hip arthroplasties (RR, 1.04; 95% CI, 0.79-1.37; P=.36). Knee arthroplasty surgeons with shorter median operative durations had a lower risk of SSI than surgeons with typical median operative durations (RR, 0.52; 95% CI, 0.43-0.64; P<.01). Short operative durations were not associated with a higher SSI risk for knee or hip arthroplasty procedures in our analysis.

  7. Rehabilitation of gait in patients after total hip arthroplasty: Comparison of the minimal invasive Yale 2-incision technique and the conventional lateral approach.

    Science.gov (United States)

    Böhm, Harald; Hagemeyer, Daniel; Thummerer, Yvonne; Kipping, Robert; Stöckle, Ulrich; Scheuerer, Konrad

    2016-02-01

    The minimal invasive anterolateral Yale 2-incision approach for total hip arthroplasty aims minimizing damage to the muscles for faster recovery of function. Therefore the hypothesis was investigated, that during the rehabilitation process the Yale approach shows a faster return to natural gait than a conventional lateral approach. Nineteen patients had the Yale, 16 the conventional Bauer approach. Instrumented gait analysis was performed 3 days, 3 and 12 month post operatively. Velocity, cadence, step length, weight bearing, thorax lean, Trendelenburg limp, hip abduction moments, and hip muscle activation times were evaluated. Three days post-surgery a significantly greater loading of the treated limb and increased hip abduction moment were observed in the Yale group. In addition, the Yale group showed its greatest improvement in walking speed and step length between at 3 days and 3 months, whereas the conventional group showed an additional significant gain between 3 and 12 month to reach a similar walking speed as the Yale group. For all hip muscles investigated, only muscle tensor fasciae latae in the conventional group showed a significant increase in activation time between 3 days and 3 months. This study showed significantly faster return to natural gait in the Yale compared to the conventional approach, which could be biomechanically related to less impairment of abductor muscles in the Yale approach.

  8. Predictors of participation in sports after hip and knee arthroplasty.

    Science.gov (United States)

    Williams, Daniel H; Greidanus, Nelson V; Masri, Bassam A; Duncan, Clive P; Garbuz, Donald S

    2012-02-01

    While the primary objective of joint arthroplasty is to improve patient quality of life, pain, and function, younger active patients often demand a return to higher function that includes sporting activity. Knowledge of rates and predictors of return to sports will help inform expectations in patients anticipating return to sports after joint arthroplasty. We measured the rate of sports participation at 1 year using the UCLA activity score and explored 11 variables, including choice of procedure/prosthesis, that might predict return to a high level of sporting activity, when controlling for potential confounding variables. We retrospectively evaluated 736 patients who underwent primary metal-on-polyethylene THA, metal-on-metal THA, hip resurfacing arthroplasty, revision THA, primary TKA, unicompartmental knee arthroplasty, and revision TKA between May 2005 and June 2007. We obtained UCLA activity scores on all patients; we defined high activity as a UCLA score of 7 or more. We evaluated patient demographics (age, sex, BMI, comorbidity), quality of life (WOMAC score, Oxford Hip Score, SF-12 score), and surgeon- and procedural/implant-specific variables to identify factors associated with postoperative activity score. Minimum followup was 11 months (mean, 12.1 months; range, 11-13 months). Preoperative UCLA activity score, age, male sex, and BMI predicted high activity scores. The type of operation and implant characteristics did not predict return to high activity sports. Our data suggest patient-specific factors predict postoperative activity rather than factors specific to type of surgery, implant, or surgeon factors. Level II, prognostic study. See the Guidelines for Authors for a complete description of levels of evidence.

  9. Prospective study comparing functional outcomes and revision rates between hip resurfacing and total hip arthroplasty: preliminary results for 2 years.

    Science.gov (United States)

    Pailhé, Régis; Reina, Nicolas; Cavaignac, Etienne; Sharma, Akash; Lafontan, Valérie; Laffosse, Jean-Michel; Chiron, Philippe

    2013-01-01

    There is a need of independent prospective studies about modern generation of hip resurfacing implants. The aim of this propective observational study was to compare the functional outcomes and revision rates with hip resurfacing arthroplasty and total hip arthroplasty and to present the preliminary results at 2 years. Patients included were recruited prospectively in the Partial Pelvic Replacement Hip Project by a single surgeon between January 2007 and January 2010. Patients were assessed with the Harris Hip Score (HHS) and Postel-Merle d'Aubigné (MDA) score and Devane Score. The end point of the study was reoperation for any cause related to the prosthesis. At a mean follow up of 38.6 months there were a total of 142 patients with hip resurfacing (group 1) [100 Durom(®) (Zimmer Inc., Warsaw, IN, USA) and 42 Birmingham Hip Resurfacing(®) (Smith & Nephew, Memphis, TN, USA)] and 278 patients with total hip arthroplasty (group 2). The results showed significantly greater gain of HHS, MDA and Devane score with hip resurfacing procedures. However, considering all the complications, the rate was significantly higher in group 16.4% vs 1.79% in group 2 (P<0.0001). In group 1 we observed 6 complications only concerned males with Durom(®) implants. The follow up of this cohort is still on going and may deliver more information on the evolution of these results in time.

  10. Prospective study comparing functional outcomes and revision rates between hip resurfacing and total hip arthroplasty: preliminary results for 2 years

    Directory of Open Access Journals (Sweden)

    Régis Pailhé

    2013-07-01

    Full Text Available There is a need of independent prospective studies about modern generation of hip resurfacing implants. The aim of this propective observational study was to compare the functional outcomes and revision rates with hip resurfacing arthroplasty and total hip arthroplasty and to present the preliminary results at 2 years. Patients included were recruited prospectively in the Partial Pelvic Replacement Hip Project by a single surgeon between January 2007 and January 2010. Patients were assessed with the Harris Hip Score (HHS and Postel-Merle d’Aubigné (MDA score and Devane Score. The end point of the study was reoperation for any cause related to the prosthesis. At a mean follow up of 38.6 months there were a total of 142 patients with hip resurfacing (group 1 [100 Durom® (Zimmer Inc., Warsaw, IN, USA and 42 Birmingham Hip Resurfacing® (Smith & Nephew, Memphis, TN, USA] and 278 patients with total hip arthroplasty (group 2. The results showed significantly greater gain of HHS, MDA and Devane score with hip resurfacing procedures. However, considering all the complications, the rate was significantly higher in group 16.4% vs 1.79% in group 2 (P<0.0001. In group 1 we observed 6 complications only concerned males with Durom® implants. The follow up of this cohort is still on going and may deliver more information on the evolution of these results in time.

  11. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Healy, W.L.; Lo, T.C.; Covall, D.J.; Pfeifer, B.A.; Wasilewski, S.A. (Lahey Clinic Medical Center, Burlington, MA (USA))

    1990-12-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700 centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy.

  12. Total Hip Arthroplasty in Systemic Lupus Erythematosus: A Systematic Review

    Directory of Open Access Journals (Sweden)

    John W. Kennedy

    2015-01-01

    Full Text Available The prognosis of systemic lupus erythematosus (SLE has greatly improved in recent years, resulting in an increased number of patients reporting musculoskeletal complications such as osteonecrosis of the femoral head. Total hip arthroplasty (THA can be utilised to alleviate the pain associated with this; however postoperative outcomes in patients with SLE are uncertain. A systematic review of the literature was conducted to identify articles presenting results of THA in SLE, and nine suitable papers were found. All papers were level IV evidence. Pooling the results, a total of 162 patients underwent 214 total hip arthroplasties. Mean follow-up was 72.5 months. The mean Harris Hip Score improved from 45.5 preoperatively to 88.6 and last follow-up. Seventeen percent of patients experienced at least one complication. Superficial wound infection occurred in 3.3%. Revision was required in 2.8% of cases. The mortality rate was 18.5% however no deaths were attributable to undergoing THA. Given the paucity of data present in the literature, more studies are required to adequately assess the postoperative outcomes of THA in patients with SLE, particularly complication rates.

  13. A Comparative Study of the Efficiency of Using Non-Selective Nonsteroidal Anti-Inflammatory Drugs in Patients with Endoprosthetic Total Knee and Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    V. V. Logvinenko

    2012-01-01

    Full Text Available Objective: to compare the postoperative efficacy and safety of non-selective nonsteroidal anti-inflammatory drugs in patients undergoing endoprosthetic total knee and hip arthroplasty (ETKAP and ETHAP. Subjects and methods. The study included 60 patients who were referred for ETKAP or ETHAP and randomly assigned to 3 groups. Groups 1, 2, and 3 patients were anesthetized with ketorolac, metamizol, and paracetamol, respectively. Real-time evaluation of the efficiency of postoperative analgesia was carried out within 3 days after surgery; the patients were questioned about bowel function, the onset of the first active movement in the ward, and occurring unpleasant sensations. Results. Reduced or no appetite was more common in the paracetamol and metamizol groups than in the ketorolac; the paracetamol group was found to have dizziness in 20% of cases, which was not observed in the two other groups. The patients who started to have routine hospital diet in the first 24 postoperative hours were significantly fewer among the paracetamol-treated patients. The shortest time to the first active movement was observed in the ketorolac group, which corresponded to the end of the first 24 hours and significantly distinguished it from the other groups. This appeared to be due to the best analgesic effect that, after epidural block, was significantly more effective (according to VAS scores in the ketorolac group, if not enhanced in any group, which agrees with information available on the drug as a worthy alternative to opioids due to its valid analgesic effect. Conclusion. __Intravenous ketorolac is a worthy alternative to narcotic analgesics in ensuring the comfortable course of the immediate postoperative period in patients operated on the knee and hip joints. Key words: ketorolac (ketorol, postoperative analgesia, endoprosthetic knee and hip arthroplasty.

  14. Total hip arthroplasty with cementless cup after acetabular fracture

    Directory of Open Access Journals (Sweden)

    Marcelo Alfonso Lugones

    2012-12-01

    Full Text Available Background Acetabular fractures are a common cause of degenerative hip arthritis. The incidence of post-traumatic osteoarthritis has been reported between 12% and 57% and avascular necrosis of the femoral head may occur in 2% to 40% after posterior fracture dislocation. The fracture is often caused by major trauma in road accidents, at work or during sports, and patients usually present for total hip replacement (THR at an earlier age than the general arthritic population. We describe and analyze our patients with uncemented acetabular reconstruction in post-traumatic arthritis and compare them with THR in non-traumatic arthritis. Methods We retrospectively evaluated 19 patients who underwent uncemented acetabular reconstruction due to post-traumatic arthritis secondary to acetabular fracture. Results The average age at the time of arthroplasty was 52.2 years (19-83. The age at the time of fracture was 47.9 years (16-81. The average time between the acetabular fracture and THR was 52.4 months (4-360. The average follow-up was 4.25 years. No acetabular component loosening or infections were seen in either group. The Harris Hip Score at an average follow-up of 4.25 years was 89.3 (57-99. The follow-up in the control group with non-traumatic arthritis was 4.9 years, and the Harris Hip Score was 94.1 points (78-100. There were no significant difference in the Harris Hip Score between groups (p = 0.24. Conclusion Uncemented acetabular reconstruction in post-traumatic arthritis secondary to acetabular fracture is a more difficult procedure than routine arthroplasty in patient with non-traumatic arthritis. In the short-term there are no clinical or radiographic differences in THR with uncemented acetabular cups in post-traumatic arthritis patients compared to patients with non-traumatic arthritis.

  15. Magnetic resonance imaging in the diagnosis and management of hip pain after total hip arthroplasty.

    Science.gov (United States)

    Cooper, H John; Ranawat, Amar S; Potter, Hollis G; Foo, Li Foong; Jawetz, Shari T; Ranawat, Chitranjan S

    2009-08-01

    Evaluation of pain following total hip arthroplasty (THA) can be challenging in the absence of radiographic pathology. This study aimed to examine the diagnostic utility of magnetic resonance imaging (MRI) in the evaluation of enigmatic hip pain following THA. We reviewed a series of patients who were evaluated with MRI after presenting with enigmatic hip pain following THA. MRI was able to demonstrate pathology in the periprosthetic tissues in all hips with minimal artifact. Patients underwent a range of conservative and operative interventions depending on the underlying pathology. If used discriminately in situations where pathology cannot be detected by conventional methods, MRI is a highly effective modality that can aid in the diagnosis of a wide range of disorders thereby allowing the clinician to determine the most appropriate intervention.

  16. Outcome measures of bipolar hip arthroplasty for atraumatic hip disorders - A preliminary report

    Directory of Open Access Journals (Sweden)

    Dudani Baldev

    2005-01-01

    Full Text Available Background: Bipolar hip arthroplasty was devised for fracture neck femur in elderly patients. Subsequently, indications have been expanded to include conditions affecting acetabulum like rheumatoid arthritis, osteoarthritis and avascular necrosis of femoral head. Materials and methods: We have studied the results of bipolar hip arthroplasty in 38 such patients, with severely involved acetabulum due to rheumatoid arthritis, avascular necrosis of femoral head and primary osteoarthritis. Acetabulum was reamed to get a tight ′equatorial′ or ′rim′ fit of the prosthesis. Prosthesis selected was 1 mm bigger than the maximum size of reamer used. Cement was used in femur whenever there was marked osteoporosis or wide medullary canal. Post operatively all patients were regularly screened for pain, range of movement, protrusio acetabuli, loosening / sinking of prosthesis and radiographic assessment of movement in the two bearings of prosthesis. Results: Overall results achieved were good to excellent in 80% of patients. Conclusions: The ultimate outcome is comparable to total hip arthroplasty. The added advantage is of low cost, simplicity of procedure and easy future revision.

  17. Prophylactic GSV surgery in elderly candidates for hip or knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Quarto Gennaro

    2016-01-01

    Full Text Available Aging is one of the major risk factors for varicose veins. The same is for Knee and Hip Osteoarthritis. Most of the patients undergoing to Hip (THA or Knee (TKA arthroplasty are over sixteen. Varicose veins, excluding thrombophilia, are the most significant risk factors for VTE after THA and TKA.

  18. Participation in sports after hip and knee arthroplasty: review of literature and survey of surgeon preferences.

    Science.gov (United States)

    McGrory, B J; Stuart, M J; Sim, F H

    1995-04-01

    To summarize previously published findings and to present the opinions of a group of reconstructive orthopedic surgeons from a single institution on participation in sports after hip or knee arthroplasty. We reviewed the literature pertaining to participation in sports after hip or knee arthroplasty and surveyed a group of orthopedic surgeons about their recommendations for resumption of various sports activities by patients who had undergone total hip or knee arthroplasty. A computerized literature search was performed, and salient issues about participation in sports after joint replacement procedures were synthesized. At the Mayo Clinic, 28 orthopedic surgeons (13 consultants and 15 fellows or residents) completed a single-page questionnaire that requested a recommendation ("yes," "no," or "depends") about patients resuming participation in 28 common sports after recovery from total hip or knee arthroplasty. Staff surgeon responses were compared with responses from fellows and residents by using the Mann-Whitney U test. Sports in which 75% of surgeons would not allow participation were identified as "not recommended," whereas sports in which 75% of surgeons would allow participation were labeled as "recommended." Fellows and residents were less likely than staff surgeons to allow return to cross-country skiing after total knee arthroplasty. Otherwise, responses from consultant surgeons and from fellows and residents did not differ significantly. Recommended sports included sailing, swimming laps, scuba diving, cycling, golfing, and bowling after hip and knee replacement procedures and also cross-country skiing after knee arthroplasty. Sports not recommended after hip or knee arthroplasty were running, waterskiing, football, baseball, basketball, hockey, handball, karate, soccer, and racquetball. After hip or knee arthroplasty, participation in no-impact or low-impact sports can be encouraged, but participation in high-impact sports should be prohibited.

  19. Bipolar hip arthroplasty as salvage treatment for loosening of the acetabular cup with significant bone defects

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2016-04-01

    Full Text Available Introduction: Revision arthroplasty of the hip is becoming increasingly important in recent years. Early primary arthroplasty and longer life expectancy of the patients increases the number of revision surgery. Revision surgery of hip arthroplasty is major surgery for the patients, especially the elderly, with significant risks concerning the general condition of the patient. The aim of this work is to evaluate the outcome of bipolar hip arthroplasty as a salvage procedure for treatment of loosening of the acetabular cup with significant acetabular bone defects after total hip replacement (THR in multi-morbid patients.Patients and methods: During the period from January 1 2007 to December 31 2011 19 revision hip surgeries were performed in , in which the loosened acetabular cup was replaced by a bipolar head. The examined patient group consisted exclusively of female patients with an average of 75 years. The predominant diagnosis was “aseptic loosening” (84.2%. All patients in our study were multi-morbid. We decided to resort to bipolar hip arthroplasty due to the compromised general condition of patients and the major acetabular bone defects, which were confirmed intraoperatively. The postoperative follow-up ranged from 0.5 to 67 months (average 19.1 months. Results: Evaluation of the modified Harris Hip Score showed an overall improvement of the function of the hip joint after surgery of approximately 45%.Surgery was less time consuming and thus adequate for patients with significantly poor general health condition. We noticed different complications in a significant amount of patients (68.4%. The most common complication encountered was the proximal migration of the bipolar head.The rate of revision following the use of bipolar hip arthroplasty in revision surgery of the hip in our patients was high (21%. Despite the high number of complications reported in our study, we have noticed significant improvement of hip joint function as well

  20. Acute periprosthetic fractures of the acetabulum after total hip arthroplasty.

    Science.gov (United States)

    Potty, Anish G; Corona, Jacqueline; Manning, Blaine T; Le, Amanda; Saleh, Khaled J

    2014-01-01

    Although periprosthetic fractures of the acetabulum are relatively uncommon after total hip arthroplasty, a variety of patient-, surgeon-, and implant-related risk factors can contribute to the occurrence of this serious complication. These risk factors, combined with the increased use of cementless acetabular cups, will likely result in an increased prevalence of these fractures in the future. By better understanding the risk factors, classification schemes, and treatment options for periprosthetic fractures of the acetabulum, orthopaedic surgeons can achieve better outcomes for their patients.

  1. The effects of short-term preoperative physical therapy and education on early functional recovery of patients younger than 70 undergoing total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Vukomanović Aleksandra

    2008-01-01

    Full Text Available Background/Aim. Hip arthroplasty is a routine operation which relieves pain in patients with osteoarthritis. The role of physical therapy after hip arthroplasty was recognized, but the importance of preoperative physical therapy and education is still to be judged. The aim of this paper was to investigate the effect of short-term preoperative program of education and physical therapy on patients' early functional recovery immediately after total hip arthroplasty (THA. Methods. This prospective study included 45 patients with hip osteoarthritis scheduled to undergo primary THA and admitted to the Department of Orthopedics of Military Medical Academy. They were randomized into 2 groups: study and control one (with and without preoperative education and physical therapy. Preoperative education was conducted through conversation (1 appointment with physiatrist and brochure. The study group was instructed to perform exercises and basic activities from the postoperative rehabilitation program (2 practical classes with physiotherapist. Effects were measured with questionnaires (Harris, Oxford and Japanese Orthopaedic Association (JOA hip scores, range of motion and visual analog scale of pain. Marks showing ability to perform basic activities and endurance were from 0 (did not perform activity to 5 (independent and secure. Analyses examined differences between the groups over the preoperative and immediate postoperative periods and 15 months after the operation. Results. There were no differences between the groups at discharge according to pain, range of motion, Harris hip score and JOA hip score. Oxford hip score did not differ between the groups 15 months after the operation. The groups started to walk at the same time, but the study group walked up and down stairs (3.7±1.66 vs 5.37±1.46, p ≤ 0.002, used toilet (2.3±0.92 vs 3.2±1.24, p ≤ 0.02 and chair (2.2±1.01 vs 3.25±1.21, p ≤ 0.006 significantly earlier than the control group. On the

  2. Hip resurfacing arthroplasty: current status and future perspectives

    Directory of Open Access Journals (Sweden)

    K Corten

    2011-03-01

    Full Text Available Hip resurfacing arthroplasty (HRA is a concept of hip replacement that allows treating young active patients with a femoral bone preserving procedure. The proposed advantages of resuming an active lifestyle with increased frequency and duration of sports activities have been shown to be realistic. The 30-year cost-effectiveness in young male patients has been shown to be higher in resurfacing compared to conventional total hip replacement (THA. However, prognosticators of an inferior outcome have also been identified. The most important patient related factors are secondary osteoarthritis as the indication for surgery such as post-childhood hip disorders or AVN, female gender, smaller component sizes and older age (>65 years for males and >55 years for females. In addition, surgical technique (approach and cementing technique and component design are also important determinant factors for the risk of failure. Moreover, concerns have surfaced with respect to high metal ion concentrations and metal ion hypersensitivities. In addition, the presumed ease of revising HRA has not reflected in improved or equal survivorship in comparison to a primary THA. This highlights the importance of identifying patient-, surgery-, and implant-related prognosticators for success or failure of HRA. Rather than vilifying the concept of hip resurfacing, detailed in depth analysis should be used to specify indications and improve implant design and surgical techniques.

  3. The influence of heterotopic ossification on functional status of hip joint following total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Pohl, F.; Seufert, J.; Flentje, M.; Koelbl, O. [Wuerzburg Univ. (Germany). Dept. of Radiotherapy; Tauscher, A.; Springorum, H.W. [Caritas Krankenhaus Bad Mergentheim (Germany). Orthopedic Clinic; Lehmann, H. [Caritas Krankenhaus Bad Mergentheim (Germany). Inst. of Radiology

    2005-08-01

    Purpose: The functional failure induced by heterotopic ossification (HO) following total hip arthroplasty (THA) was analyzed and correlated to the radiologic failure. Patients and methods: From July 1997 to July 2001, 315 patients (345 hips) received THA indicated by a hypertrophic osteoarthritis of higher degree (Kellgren grade III, IV). All patients were irradiated prophylactically for prevention of HO on the evening before surgery with a 7-Gy single fraction. The patients' median age was 66.3 years. Radiologic failure was assessed by comparison of pre- and postoperative hip X-rays (immediately and 6 months after surgery). Analysis of radiographs was performed according to the Brooker Score. Clinical failure was appraised by measurement of passive range of motion (ROM) of the hip joint with a standard goniometer. The t-test was used for statistical analysis. Results: 281 patients (81.5%) did not develop HO. HO of Brooker grade I or II was found in 58 patients (16.8%). Six patients (1.7%) developed HO Brooker grade III or IV. There was a significant negative correlation between the degree of radiologic and clinical failure. ROM differed significantly between patients with HO Brooker grade 0, I, II and patients with HO Brooker grade III, IV. Comparing the pre- and postoperative ROM, all patients with Brooker grade 0, I and II showed a significant improvement of flexion, internal and external rotation, abduction and adduction movement. Patients with HO Brooker grade III and IV showed no improvement of ROM in the postoperative follow-up. Conclusion: The development of HO following THA influences the physical function of the hip joint dependent on the degree of ossification. HO of lower degree (Brooker I, II) does not influence the clinical outcome, whereas HO of higher degree (Brooker III, IV) reduces the function of hip arthroplasty. Therefore, the purpose of a prophylactic therapy must be to reduce HO of higher degree. (orig.)

  4. Total hip arthroplasty: what information do we offer patients on websites of hospitals?

    NARCIS (Netherlands)

    Brunnekreef, J.J.; Schreurs, B.W.

    2011-01-01

    BACKGROUND: Physicians face a new challenge; the self-educated patient. The internet is an important source that patients use to become self-educated. However, the individual choice for best treatment is difficult. The aim of this study was to investigate what kind of information is offered to total

  5. Periprosthetic fracture of the acetabulum during total hip arthroplasty in a patient with Paget's disease.

    Science.gov (United States)

    McGrory, B J

    1999-04-01

    The case of a patient with Paget's disease of the pelvis (acetabulum) who had an intraoperative posterior wall fracture during the insertion of a noncemented acetabular component into an under-reamed acetabular bed of sclerotic Pagetoid bone is reported. This unusual complication has not, to my knowledge, been previously reported. Patients with sclerotic bone, like those with osteoporotic bone, may also be at risk for periprosthetic acetabular fractures when an under-reaming technique is used.

  6. Cobalt Cardiomyopathy Secondary to Hip Arthroplasty: An Increasingly Prevalent Problem

    Directory of Open Access Journals (Sweden)

    Russel Tilney

    2017-01-01

    Full Text Available A forty-year-old man experienced worsening heart failure four years following bilateral complicated total hip replacement. His condition was extensively worked up but no underlying pathology was immediately evident. Given the cobalt-chromium alloy component present in the hip arthroplasties, the raised cobalt blood levels, and a fitting clinical picture coupled with radiological findings, the patient underwent right hip revision. Evidence of biotribocorrosion was present on direct visualisation intraoperatively. The patient subsequently experienced symptomatic improvement (NYHA class III to class I and echocardiography showed recovery of ejection fraction. Cobalt exists as a bivalent and trivalent molecule in circulation and produces a cytotoxicity profile similar to nanoparticles, causing neurological, thyroid, and cardiological pathology. Blood levels are not entirely useful as there is no identifiable conversion factor for levels in whole blood, serum, and erythrocytes which seem to act independently of each other. Interestingly cobalt cardiomyopathy is frequently compounded by other possible causes of cardiomyopathy such as alcohol and a link has been postulated. Definitive treatment is revision of the arthroplasty as other treatments are unproven.

  7. Cemented total hip arthroplasty with Boneloc bone cement.

    Science.gov (United States)

    Markel, D C; Hoard, D B; Porretta, C A

    2001-01-01

    Boneloc cement (WK-345, Biomet Inc, Warsaw, Ind) attempted to improve cement characteristics by reducing exotherm during polymerization, lowering residual monomer and solubility, raising molecular weight, and lowering airborne monomer and aromatic amines. To study the efficacy of this cement, a selected group of 20 patients were prospectively enrolled and followed up after hip arthroplasty. All components were cemented. During the enrollment period, approximately 70 other hip arthroplasties were performed. Clinical evaluation was based on the Harris hip score. Radiographic evaluation was based on assessment of position of the components, subsidence, and/or presence of radiolucencies. Patients had follow-up for an average of 42 months (11 to 58 months); 1 was lost to follow-up. Of these, 7 (35%) had failure at last follow-up. Despite its initial promise, Boneloc cement had an unacceptably high failure rate over a relatively short follow-up period and is not recommended for use. Despite the longevity and odor toxicity problems with conventional bone cement, new cement technologies must be approached with caution.

  8. Risk Prediction Tools for Hip and Knee Arthroplasty.

    Science.gov (United States)

    Manning, David W; Edelstein, Adam I; Alvi, Hasham M

    2016-01-01

    The current healthcare environment in America is driven by the concepts of quality, cost containment, and value. In this environment, primary hip and knee arthroplasty procedures have been targeted for cost containment through quality improvement initiatives intended to reduce the incidence of costly complications and readmissions. Accordingly, risk prediction tools have been developed in an attempt to quantify the patient-specific assessment of risk. Risk prediction tools may be useful for the informed consent process, for enhancing risk mitigation efforts, and for risk-adjusting data used for reimbursement and the public reporting of outcomes. The evaluation of risk prediction tools involves statistical measures such as discrimination and calibration to assess accuracy and utility. Furthermore, prediction tools are tuned to the source dataset from which they are derived, require validation with external datasets, and should be recalibrated over time. However, a high-quality, externally validated risk prediction tool for adverse outcomes after primary total joint arthroplasty remains an elusive goal.

  9. Nursing in fast-track total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Specht, Kirsten; Kjaersgaard-Andersen, Per; Kehlet, Henrik

    2015-01-01

    AIM: To describe the increased activity in total hip arthroplasty (THA) and total knee arthroplasty (TKA) from 2002 to 2012 in a single orthopaedic department, the organisation of fast-track and its consequences for nursing care. METHODS: Retrospective, descriptive design. Data collection; from...... the hospital administrative database, local descriptions of fast-track, personal contact and discussion with staff. RESULTS: The number of operations increased threefold from 351 operations in 2002 to 1024 operations in 2012. In 2012, THA/TKA patients had a postoperative mean LOS of 2.6/2.8 days. Nurses had......, be considered a worthwhile investment to employ expert/highly qualified professional nurses in fast-track THA and TKA units....

  10. Extensively Coated Cementless Femoral Components in Revision Hip Arthroplasty.

    Science.gov (United States)

    Greidanus, Nelson; Antoniou, John; Paprosky, Wayne

    2000-10-01

    A septic loosening and osteolysis can compromise the available host bone in patients requiring revision hip arthroplasty. Secure fixation of revision femoral components may not be possible if reliant only on proximal femoral bone for biologic fixation or cement interdigitation. The challenge for the revision arthroplasty surgeon is to find the best method to secure the implant in a femur with deficient bone proximally that will provide stability for load bearing and motion. In addition to providing stability, the implant must be durable and maintain long-term fixation. With over 16 years of experience with fully porous coated femoral revision implants, we have found that maximizing prosthetic-bone fit in the proximal femoral diaphyseal bone provides reliable long-term fixation in the majority of femoral revision cases.

  11. The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty.

    NARCIS (Netherlands)

    Brokelman, R.B.G.; Haverkamp, D.; Loon, C. van; Hol, A.; Kampen, A. van; Veth, R.P.H.

    2012-01-01

    INTRODUCTION: Patient satisfaction becomes more important in our modern health care system. The assessment of satisfaction is difficult because it is a multifactorial item for which no golden standard exists. One of the potential methods of measuring satisfaction is by using the well-known visual an

  12. Early patient-reported outcomes versus objective function after total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Luna, I E; Kehlet, H; Peterson, Barry

    2017-01-01

    ). Secondary measures were correlations to objectively assessed change in physical performance (paced-walk, chair-stand, stair-climb tests) at day 14 (THA) or 21 (TKA) and actual physical activity (actigraphy) measured at day 12 and 13 (THA) or 19 and 20 (TKA). RESULTS: Patients reported improved physical...

  13. Unstable total hip arthroplasty: detailed overview.

    Science.gov (United States)

    Berry, D J

    2001-01-01

    Hip dislocation is one of the most common complications of THA. Good preoperative planning, good postoperative patient education, accurate intraoperative component positioning, rigorous intraoperative testing of hip stability, and good repair of soft tissues during closure all help prevent dislocation. Early postoperative dislocations and first or second dislocations usually are treated with closed reduction and a hip guide brace or hip spica cast, but when dislocation becomes recurrent, surgical treatment usually is needed. When possible, surgical treatment is based on identifying and treating a specific problem leading to the dislocation, such as implant malposition, inadequate soft-tissue tension, or impingement. In selected circumstances, constrained implants or bipolar or tripolar implants provide powerful tools to restore hip stability.

  14. Fracture of the ceramic epiphysis in hip arthroplasty.

    Science.gov (United States)

    Toni, A; Terzi, S; Sudanese, A; Zappoli, F A; Giunti, A

    1996-01-01

    Between November 1985 and October 1993, a total of 694 ceramic-ceramic hip arthroplasties were implanted; up until 1987 the alumina used in the first 82 cases was Ostalox, produced by IMEC of Caravaggio, characterized by poor control of the size of the crystals; after 1987 Biolox alumina of the Feldmhule company was used in 612 cases. Fracture of the ceramic head occurred in 2 cases; in both patients ceramic was of the Ostalox type, meaning a 2.4% incidence of fracture; up until the present none of the 612 Biolox heads has presented this complication.

  15. Endotoxins in surgical instruments of hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Vania Regina Goveia

    2016-06-01

    Full Text Available Abstract OBJECTIVE To investigate endotoxins in sterilized surgical instruments used in hip arthroplasties. METHOD A descriptive exploratory study conducted in a public teaching hospital. Six types of surgical instruments were selected, namely: acetabulum rasp, femoral rasp, femoral head remover, chisel box, flexible bone reamer and femoral head test. The selection was based on the analysis of the difficulty in removing bone and blood residues during cleaning. The sample was made up of 60 surgical instruments, which were tested for endotoxins in three different stages. The EndosafeTM Gel-Clot LAL (Limulus Amebocyte Lysate method was used. RESULT There was consistent gel formation with positive analysis in eight instruments, corresponding to 13.3%, being four femoral rasps and four bone reamers. CONCLUSION Endotoxins in quantity ≥0.125 UE/mL were detected in 13.3% of the instruments tested.

  16. Intraoperative Hypothermia in Total Hip and Knee Arthroplasty.

    Science.gov (United States)

    Frisch, Nicholas B; Pepper, Andrew M; Rooney, Edward; Silverton, Craig

    2016-10-25

    Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are common and successful orthopedic procedures, and as their frequency continues to increase substantially, the focus on limiting perioperative complications heightens. Intraoperative normothermia is recommended to minimize additional complications, but limited evidence exists regarding the effect of hypothermia on orthopedic patients. The purpose of this retrospective study was to determine the incidence of perioperative hypothermia in the setting of TKA and THA, and to evaluate its impact on complications and outcomes. The clinical records of 2580 consecutive patients who underwent TKA or THA at a single institution between January 1, 2011, and December 31, 2013 were reviewed. After excluding patients with complex or revision procedures, a total of 2397 patients comprised the study population. Patient demographic data, surgery-specific data, postoperative complications, length of hospital stay, and 30-day readmission were recorded. Patients with a mean intraoperative temperature less than 36°C were identified as hypothermic. Statistical analysis evaluated associations with hypothermia and the effect on complications and outcomes. The incidence of mean intraoperative hypothermia was 37%, 43.9%, and 32.6% for arthroplasty, THA, and TKA, respectively. General anesthesia was significantly associated with hypothermia (P<.001). Women and THA patients were at higher risk for hypothermia. In the arthroplasty and THA cohorts, longer operating room time and re-warmer use were associated with hypothermia (P=.010). Overall, hypothermia was associated with increased estimated blood loss, but no increase in associated transfusion was demonstrated (P=.006). Hypothermia was not associated with postoperative complications. [Orthopedics. 201x; xx(x):xx-xx.].

  17. The strength and function of hip abductors following anterolateral minimally invasive total hip arthroplasty

    Institute of Scientific and Technical Information of China (English)

    Tan Jixiang; Chen Hong; Chen Cheng; Liang Xi; Huang Wei

    2014-01-01

    Objective:To analyze the extent of postoperative hip abductor insufficiency in primary total hip arthroplasty (THA) patients undergoing anterolateral minimally invasive (ALMI) approach,and to investigate whether the clinical outcomes are more favorable in femoral neck fracture (FNF) patients than in non-femoral neck fracture (nFNF) patients.Methods:A total of 48 patients were enrolled in this study.Each patient underwent a clinical examination preoperatively and 6,12,24 and 48 weeks postoperatively.The abductor torque,Trendelenburg's sign,gait velocity,Harris hip score,Oxford hip score,Westren Ontario and McMaster Universities (WOMAC) score and visual analog scale pain score were recorded.Statistical evaluation was performed with SPSS software version 18.0.The significance level was set at P<0.05.Results:The abductor torque of the operated hip and the recovery ratio showed a gradual improving tendency from 6 weeks postoperatively until the last follow-up.Gait velocity,Harris hip score,Oxford hip score and WOMAC score improved significantly after the operation until 24 weeks postoperatively.In the FNF group,the abductor torque of the operated side and the recovery ratio were significantly higher than in nFNF group at 6 weeks postoperatively,however,as time passed,this trend tended to disappear.Conclusion:This study demonstrates that patients can obtain good abductor strength and function in the early postoperative period and the hip abductor function of patients who suffer from hip osteoarthritis,rheumatoid arthritis,avascular necrosis of the femoral head could be significantly improved following ALMI THA.

  18. Infection of a total hip arthroplasty with actinomyces israelii: Report of a case

    Directory of Open Access Journals (Sweden)

    Feiran Wu

    2011-01-01

    Full Text Available Context : Infection of following total hip arthroplasties can be classified based on the timing of infection. Late infections with Actinomyces israelii are extremely rare with only 3 previously reported cases in literature. We present another case of a late infection with Actinomyces israelii in a total hip arthroplasty 9 years following implantation. Case Report : A 71-year-old male with diabetes mellitus presented with right hip pain 9 years following a total hip arthroplasty. Physical examination revealed localised pain and biochemical investigations showed elevated inflammatory markers. X-rays were suspicious for infection and a collection around the prosthesis was confirmed by MRI scan. The patient underwent debridement and removal of prosthesis. Peri-operative specimen cultures isolated Actinomyces israelii. The patient responded to a combination of vancomycin followed by ciprofloxacin and linezolid therapy before undergoing a successful second-stage reimplantation surgery. Conclusion : This is the first reported case of late haematogenous infection by Actinomyces israelii in a total hip arthroplasty in a patient with diabetes mellitus as the only risk factor. The patient was successfully treated with antibiotic therapy and two-stage reimplantation arthroplasty.

  19. An Unexpected Complication of Hip Arthroplasty: Knee Dislocation

    Directory of Open Access Journals (Sweden)

    Serdar Yilmaz

    2015-01-01

    Full Text Available An increasing number of patients with hip fracture have been seen with osteoporosis associated with osteoarthritis. Although knee dislocation is related to high-energy trauma, low-grade injuries can also lead to knee dislocation which is defined as “ultra-low velocity dislocation.” The case reported here is of an 82-year-old patient who presented with a left intertrochanteric hip fracture. Partial arthroplasty was planned because of osteoporosis. In the course of surgery, degenerative arthritic knee was dislocated during the hip reduction maneuver with the application of long traction. The neurovascular examination was intact, but the knee was grossly unstable and was dislocated even in a brace; thus a hinged knee prosthesis was applied nine days after surgery. The patient was mobilized with crutches after the knee prosthesis but exercise tolerance was diminished. In conclusion, it should be emphasized that overtraction must be avoided during the hip reduction maneuver in patients with advanced osteoarthritic knee.

  20. Total Hip Arthroplasty – over 100 years of operative history

    Directory of Open Access Journals (Sweden)

    Stephen Richard Knight

    2011-11-01

    Full Text Available Total hip arthroplasty (THA has completely revolutionised the nature in which the arthritic hip is treated, and is considered to be one of the most successful orthopaedic interventions of its generation (1. With over 100 years of operative history, this review examines the progression of the operation from its origins, together with highlighting the materials and techniques that have contributed to its development. Knowledge of its history contributes to a greater understanding of THA, such as the reasons behind selection of prosthetic materials in certain patient groups, while demonstrating the importance of critically analyzing research to continually determine best operative practice. Finally, we describe current areas of research being undertaken to further advance techniques and improve outcomes.

  1. 2017 American College of Rheumatology/American Association of Hip and Knee Surgeons Guideline for the Perioperative Management of Antirheumatic Medication in Patients With Rheumatic Diseases Undergoing Elective Total Hip or Total Knee Arthroplasty.

    Science.gov (United States)

    Goodman, Susan M; Springer, Bryan; Guyatt, Gordon; Abdel, Matthew P; Dasa, Vinod; George, Michael; Gewurz-Singer, Ora; Giles, Jon T; Johnson, Beverly; Lee, Steve; Mandl, Lisa A; Mont, Michael A; Sculco, Peter; Sporer, Scott; Stryker, Louis; Turgunbaev, Marat; Brause, Barry; Chen, Antonia F; Gililland, Jeremy; Goodman, Mark; Hurley-Rosenblatt, Arlene; Kirou, Kyriakos; Losina, Elena; MacKenzie, Ronald; Michaud, Kaleb; Mikuls, Ted; Russell, Linda; Sah, Alexander; Miller, Amy S; Singh, Jasvinder A; Yates, Adolph

    2017-08-01

    This collaboration between the American College of Rheumatology and the American Association of Hip and Knee Surgeons developed an evidence-based guideline for the perioperative management of antirheumatic drug therapy for adults with rheumatoid arthritis (RA), spondyloarthritis (SpA) including ankylosing spondylitis and psoriatic arthritis, juvenile idiopathic arthritis (JIA), or systemic lupus erythematosus (SLE) undergoing elective total hip (THA) or total knee arthroplasty (TKA). A panel of rheumatologists, orthopedic surgeons specializing in hip and knee arthroplasty, and methodologists was convened to construct the key clinical questions to be answered in the guideline. A multi-step systematic literature review was then conducted, from which evidence was synthesized for continuing versus withholding antirheumatic drug therapy and for optimal glucocorticoid management in the perioperative period. A Patient Panel was convened to determine patient values and preferences, and the Grading of Recommendations Assessment, Development and Evaluation methodology was used to rate the quality of evidence and the strength of recommendations, using a group consensus process through a convened Voting Panel of rheumatologists and orthopedic surgeons. The strength of the recommendation reflects the degree of certainty that benefits outweigh harms of the intervention, or vice versa, considering the quality of available evidence and the variability in patient values and preferences. The guideline addresses the perioperative use of antirheumatic drug therapy including traditional disease-modifying antirheumatic drugs, biologic agents, tofacitinib, and glucocorticoids in adults with RA, SpA, JIA, or SLE who are undergoing elective THA or TKA. It provides recommendations regarding when to continue, when to withhold, and when to restart these medications, and the optimal perioperative dosing of glucocorticoids. The guideline includes 7 recommendations, all of which are conditional

  2. [Hip resurfacing in patients under 55 years of age

    NARCIS (Netherlands)

    Schmitz, M.W.J.L.; Veth, R.P.H.; Schreurs, B.W.

    2011-01-01

    Hip resurfacing arthroplasty was introduced as an alternative to the conventional total hip arthroplasty which had shown suboptimal results in younger patients. Application of the resurfacing technique in younger patients has increased over the last few years. To date, no randomized controlled trial

  3. Review of quality of x-rays for templating for total hip arthroplasty.

    Science.gov (United States)

    Khan, Faiz; Ahmad, Tayyab; Condon, Finbarr; Lenehan, Brian

    2015-03-01

    Digital templating of x-rays for total hip arthroplasty is used routinely for pre-operative planning. This is to assure that appropriately sized implants are selected to replicate patient's hip biomechanics. Multiple studies have shown that templating does not always correspond to the final implants used. The aim of this study was to assess the suitability of the x-rays taken pre-operatively for templating for total hip arthroplasty. We undertook a review of a series of pre-operative templating pelvis x-rays in 100 consecutive patients undergoing total hip arthroplasty. These x-rays were compared against set criteria to determine their suitability for use for templating. We determined that six x-rays met the criteria whereas ninety four x-rays did not meet the criteria for suitable x-rays. Twenty patients had repeat x-rays. The reasons for unsuitability were inadequate opposite femur (66%), absence or incomplete template (54%), inadequate femur length (47%), external rotation (39%), absence of opposite hip (4%). The twenty repeated x-rays were also reviewed for the same parameters and two (10%) satisfied the established criteria. It is imperative that x-rays for templating for total hip arthroplasty are done to a strict standard to obtain an x-ray that is appropriate for templating and there is minimal exposure of the patient to irradiation.

  4. Delayed cementless total hip arthroplasty for neglected dislocation of hip combined with complex acetabular fracture and deficient bone stock

    Directory of Open Access Journals (Sweden)

    Gavaskar Ashok S

    2012-12-01

    Full Text Available 【Abstract】Total hip arthroplasty (THA for an un-treated acetabular fracture is technically challenging and the long-term result is not so favorable. A 45-year-old fe-male patient with untreated column and comminuted poste-rior wall fracture of the acetabulum was treated in our insti-tution by reconstruction of the posterior wall using iliac strut autograft and plate stabilization of the posterior col-umn with cancellous grafting and cementless THA in a single stage. At 3 years’ follow-up, the patient was independently mobile without limb length discrepancy. Radiological evalu-ation showed well integrated components and bone grafts. No evidence of aseptic loosening or osteolysis was found. This report aims to emphasize that bony acetabular recon-struction allows the use of primary hip components, which improves prosthesis longevity and preserves bone stock for a future revision. Key words: Acetabulum; Fractures, bone; Hip dislocation; Arthroplasty, replacement, hip

  5. Psychological factors as risk factors for poor hip function after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Benditz A

    2017-02-01

    Full Text Available Achim Benditz,1 Petra Jansen,2 Jan Schaible,1 Christina Roll,1 Joachim Grifka,1 Jürgen Götz1 1Department of Orthopedics, University Medical Center Regensburg, Asklepios Klinikum Bad Abbach, Bad Abbach, 2Department of Sport Science, University of Regensburg, Regensburg, Germany Abstract: Recovery after total hip arthroplasty (THA is influenced by several psychological aspects, such as depression, anxiety, resilience, and personality traits. We hypothesized that preoperative depression impedes early functional outcome after THA (primary outcome measure. Additional objectives were perioperative changes in the psychological status and their influence on perioperative outcome. This observational study analyzed depression, anxiety, resilience, and personality traits in 50 patients after primary unilateral THA. Hip functionality was measured by means of the Harris Hip Score. Depression, state anxiety, and resilience were evaluated preoperatively as well as 1 and 5 weeks postoperatively. Trait anxiety and personality traits were measured once preoperatively. Patients with low depression and anxiety levels had significantly better outcomes with respect to early hip functionality. Resilience and personality traits did not relate to hip functionality. Depression and state anxiety levels significantly decreased within the 5-week stay in the acute and rehabilitation clinic, whereas resilience remained at the same level. Our study suggests that low depression and anxiety levels are positively related to early functionality after THA. Therefore, perioperative measurements of these factors seem to be useful to provide the best support for patients with risk factors. Keywords: total hip arthroplasty, psychological factors, depression, state anxiety, trait anxiety, resilience, personality traits

  6. Implant survival of the most common cemented total hip devices from the Nordic Arthroplasty Register Association database

    DEFF Research Database (Denmark)

    Junnila, Mika; Laaksonen, Inari; Eskelinen, Antti

    2016-01-01

    Background and purpose - According to previous Nordic Arthroplasty Register Association (NARA) data, the 10-year implant survival of cemented total hip arthroplasties (THAs) is 94% in patients aged 65-74 and 96% in patients aged 75 or more. Here we report a brand-level comparison of cemented THA...

  7. [Cementless total hip arthroplasty after acute femoral neck fracture in active patients. Prospective matched study with a minimum follow-up of 5 years].

    Science.gov (United States)

    Lizaur-Utrilla, A; Sanz-Reig, J; Miralles-Muñoz, F A

    2014-01-01

    To evaluate outcomes of cementless total hip replacement after acute femoral neck fracture in active patients. A prospective matched study was conducted to compare the results between 76 patients with fractures and 76 patients with osteoarthritis. The Harris score, short-WOMAC and SF-12 were used for the clinical assessment. The mean follow-up was 7.3 years (range 5-11). There were no significant differences in medical or surgical complications between the 2 groups. Functional outcomes were similar, but more walking aids were used in fracture group. There were 6 revisions among the fractures group (one dislocation, 2 deep infections, 3 aseptic loosening), and 2 aseptic loosening among controls. There was no significant difference in arthroplasty survival at 10 years (88.7 vs. 96.1%, P=.15). The mortality rates at 2 and 10 years were similar. Cementless total hip replacement for treatment of acute femoral neck fracture showed similar results to those of elective surgery for osteoarthritis in these selected patients. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.

  8. Meralgia paresthetica of the contralateral leg after total hip arthroplasty.

    Science.gov (United States)

    Weier, Chris A; Jones, Lynne C; Hungerford, Marc W

    2010-04-01

    In the United States, total hip arthroplasty (THA) is typically performed with the patient in the lateral decubitus position. Positioning of the morbidly obese patient can be technically challenging and may require special positioning equipment. Although the increased incidence of complications after THA in obese patients has been well documented, neurologic complications in the contralateral limb are rare. This article describes a case of a patient with impairment of the lateral femoral cutaneous nerve in the contralateral leg after THA.A 55-year-old woman with a body mass index of 34.24 kg/m(2) underwent THA in the right lateral decubitus position. Because of her body habitus, a bean-bag positioner was used. Total hip arthroplasty was performed using a direct lateral approach. Intraoperative surgical time was 2.5 hours, and total anesthesia time was 3.5 hours. A few days postoperatively, the patient began to experience "burning and shooting" pain in the contralateral hip, but she did not report this pain until 6 weeks postoperatively. She was treated initially with a single lidocaine injection. When this was ineffective, she was treated with topiramate (100 mg daily) and vitamin B6 (100 mg orally twice daily). The symptoms lessened markedly at 5 months and resolved completely at 9 months postoperatively.Meralgia paresthetica is an uncommon, but known, complication of THA. To our knowledge, it has been reported only in the operative limb. This report reinforces the need for careful positioning to avoid pressure over the anterior superior iliac spine intraoperatively. Copyright 2010, SLACK Incorporated.

  9. [Irritation of the iliopsoas tendon after total hip arthroplasty].

    Science.gov (United States)

    Hessmann, M H; Hübschle, L; Tannast, M; Siebenrock, K A; Ganz, R

    2007-08-01

    Chronic irritation of the iliopsoas tendon is a rare cause of persistent pain after total joint replacement of the hip. In the majority of cases, pain results from a mechanical conflict between the iliopsoas tendon and the anterior edge of the acetabular cup after total hip arthroplasty. Pain can be reproduced by active flexion of the hip and by active raising of the straightened leg. In addition, painful leg raising against resistance and passive hyperextension are suggestive of an irritation of the iliopsoas tendon. Symptoms evolve from a mechanical irritation of the iliopsoas tendon and an oversized or retroverted acetabular cup, screws penetrating into the inner aspect of the ilium, or from bone cement protruding beyond the anterior acetabular rim. The diagnosis may be assumed on conventional radiographs and confirmed by CT scans. Fifteen patients with psoas irritation after total hip replacement are reported on. Eleven patients were treated surgically. The acetabular cup was revised and reoriented with more anteversion in six patients, isolated screws penetrating into the tendon were cut and leveled in three patients, and prominent bone cement in conflict with the tendon was resected once. A partial release of the iliopsoas tendon only was performed in another patient. Follow-up examination (range: 11-89 months) revealed that nine patients were free of pain and two patient had mild residual complaints. Psoas irritation in combination with total hip replacement can be prevented by a correct surgical technique, especially with proper selection of the cup size and insertion of the acetabular cup avoiding a rim position exceeding the level of the anterior acetabular rim.

  10. Identifying the procedural gap and improved methods for maintaining accuracy during total hip arthroplasty.

    Science.gov (United States)

    Gross, Allan; Muir, Jeffrey M

    2016-09-01

    Osteoarthritis is a ubiquitous condition, affecting 26 million Americans each year, with up to 17% of adults over age 75 suffering from one variation of arthritis. The hip is one of the most commonly affected joints and while there are conservative options for treatment, as symptoms progress, many patients eventually turn to surgery to manage their pain and dysfunction. Early surgical options such as osteotomy or arthroscopy are reserved for younger, more active patients with less severe disease and symptoms. Total hip arthroplasty offers a viable solution for patients with severe degenerative changes; however, post-surgical discrepancies in leg length, offset and component malposition are common and cause significant complications. Such discrepancies are associated with consequences such as low back pain, neurological deficits, instability and overall patient dissatisfaction. Current methods for managing leg length and offset during hip arthroplasty are either inaccurate and susceptible to error or are cumbersome, expensive and lengthen surgical time. There is currently no viable option that provides accurate, real-time data to surgeons regarding leg length, offset and cup position in a cost-effective manner. As such, we hypothesize that a procedural gap exists in hip arthroplasty, a gap into which fall a large majority of arthroplasty patients who are at increased risk of complications following surgery. These complications and associated treatments place significant stress on the healthcare system. The costs associated with addressing leg length and offset discrepancies can be minor, requiring only heel lifts and short-term rehabilitation, but can also be substantial, with revision hip arthroplasty costs of up to $54,000 per procedure. The need for a cost-effective, simple to use and unobtrusive technology to address this procedural gap in hip arthroplasty and improve patient outcomes is of increasing importance. Given the aging of the population, the projected

  11. Can consistent benchmarking within a standardized pain management concept decrease postoperative pain after total hip arthroplasty? A prospective cohort study including 367 patients

    Directory of Open Access Journals (Sweden)

    Benditz A

    2016-12-01

    Full Text Available Achim Benditz,1 Felix Greimel,1 Patrick Auer,2 Florian Zeman,3 Antje Göttermann,4 Joachim Grifka,1 Winfried Meissner,4 Frederik von Kunow1 1Department of Orthopedics, University Medical Center Regensburg, 2Clinic for anesthesia, Asklepios Klinikum Bad Abbach, Bad Abbach, 3Centre for Clinical Studies, University Medical Center Regensburg, Regensburg, 4Department of Anesthesiology and Intensive Care, Jena University Hospital, Jena, Germany Background: The number of total hip replacement surgeries has steadily increased over recent years. Reduction in postoperative pain increases patient satisfaction and enables better mobilization. Thus, pain management needs to be continuously improved. Problems are often caused not only by medical issues but also by organization and hospital structure. The present study shows how the quality of pain management can be increased by implementing a standardized pain concept and simple, consistent, benchmarking.Methods: All patients included in the study had undergone total hip arthroplasty (THA. Outcome parameters were analyzed 24 hours after surgery by means of the questionnaires from the German-wide project “Quality Improvement in Postoperative Pain Management” (QUIPS. A pain nurse interviewed patients and continuously assessed outcome quality parameters. A multidisciplinary team of anesthetists, orthopedic surgeons, and nurses implemented a regular procedure of data analysis and internal benchmarking. The health care team was informed of any results, and suggested improvements. Every staff member involved in pain management participated in educational lessons, and a special pain nurse was trained in each ward.Results: From 2014 to 2015, 367 patients were included. The mean maximal pain score 24 hours after surgery was 4.0 (±3.0 on an 11-point numeric rating scale, and patient satisfaction was 9.0 (±1.2. Over time, the maximum pain score decreased (mean 3.0, ±2.0, whereas patient satisfaction

  12. Comparisons of clinically based outcome measures and laboratory-based outcome measure for balance in patients following total hip and knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Jogi P

    2017-04-01

    Full Text Available Pankaj Jogi, Tom Overend, John Kramer School of Physical Therapy, University of Western Ontario, London, ON, Canada Background: Information available in the literature on clinically based and laboratory-based outcome measures of balance is limited. How much information is provided by clinically based outcome measures compared to laboratory-based measure in patients with total hip (THA and knee arthroplasty (TKA is not known. Aim: The purpose of this study was to determine the relationship between selected clinically based outcome measures and laboratory-based force platform measure in patients following THA and TKA. Methods: Patients who underwent THA (n = 26 and TKA (n = 28 were evaluated at about 5–7 weeks following surgery. Participants were assessed using four clinically based outcome measures – 1 the Berg Balance Scale (BBS, 2 the Timed Up and Go test (TUG, 3 the Activities-specific Balance Confidence Scale (ABC, and 4 the Western Ontario McMaster Universities Osteoarthritis Index-function subscale (WOMAC-function – and one laboratory-based force plate measure (95% ellipse area. Results: Moderate correlations were observed between the BBS and the 95% ellipse area of force plate (r = 0.46–0.51 for the two-legged stance, the anterior lean stance, and the posterior lean stance. Fair correlations were observed between TUG and the 95% ellipse area of force plate (r = 0.31–0.37 for all the three test conditions. Low correlations were observed for the ABC and the WOMAC-function with the 95% ellipse area of force plate (r = 0.11–0.25 for all the three test conditions. Conclusion: The BBS demonstrated the greatest correlations with the 95% ellipse area of the force plate measure and should be preferred by physical therapists over the TUG, the ABC, and the WOMAC-function to assess balance in patients with THA and TKA. Keywords: total knee arthroplasty, total hip arthroplasty, force plate, clinical measures, balance

  13. A Simple Mathematical Standardized Measurement of Acetabulum Anteversion after Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Chen-Kun Liaw

    2008-01-01

    Full Text Available We invented a standardization method to measure the cup's anteversion after total hip arthroplasty without the influence of patient's position. We measured 68 radiographs of 10 patients after total hip replacement (THR and calculated the error of each measurement, defined as the difference with the average of the same measuring method on the same patient. We also calculated the repeatability standard deviation (RSD of each method according to the American Society for Testing and Materials, ASTM E691.

  14. Challenges in Total Hip Arthroplasty in the Setting of Developmental Dysplasia of the Hip.

    Science.gov (United States)

    Greber, Eric M; Pelt, Christopher E; Gililland, Jeremy M; Anderson, Mike B; Erickson, Jill A; Peters, Christopher L

    2017-09-01

    Developmental dysplasia of the hip (DDH) is a recognized cause of secondary arthritis, which may eventually lead to total hip arthroplasty (THA). An understanding of the common acetabular and femoral morphologic abnormalities will aid the surgeon in preparing for the complexity of the surgical case. We present the challenges associated with acetabular and femoral morphologies that may be present in the dysplastic hip and discuss surgical options to consider when performing THA. In addition, common complications associated with this population are reviewed. The complexity of THA in the DDH patient is due to a broad range of pathomorphologic changes of the acetabulum and femur, as well as the diverse and often younger age of these patients. As such, THA in the DDH patient may offer a typical primary hip arthroplasty or be a highly complex reconstruction. It is important to be familiar with all the subtleties associated with DDH in the THA population. The surgeon must be prepared for bone deficiency when reconstructing the acetabulum and should place the component low and medial (at the anatomic hip center), and avoid oversizing the acetabular component. Femoral dysplasia is also complex and variable, and the surgeon must be prepared for different stem choices that allow for decoupling of the metaphyseal stem fit from the implanted stem version. In Crowe III and IV dysplasia, femoral derotation/shortening osteotomy may be required. Many complications associated with THA in the DDH patient may be mitigated with careful planning and surgical technique. Performed correctly, THA can yield excellent results in this complex patient population. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Long-Term Outcome after Rehabilitation of Bilateral Total Hip Arthroplasty in Renal Transplant Recipient – A Case Report

    Directory of Open Access Journals (Sweden)

    Erieta Nikolikj Dimitrova

    2016-02-01

    CONCLUSION: Rehabilitation is integral part of multidisciplinary treatment of renal transplant recipient after total hip arthroplasty. Regular exercise training of these patients is very important for improving of their long-term outcome.

  16. Two-stage revision of infected hip arthroplasty using a shortened post-operative course of antibiotics.

    LENUS (Irish Health Repository)

    McKenna, Paul B

    2009-04-01

    We present a series of 30 consecutive patients with 31 infected total hip arthroplasties treated by a single surgeon over a 4-year period in whom a shortened post-operative course of antimicrobial chemotherapy was used.

  17. The Current State of Screening and Decolonization for the Prevention of Staphylococcus aureus Surgical Site Infection After Total Hip and Knee Arthroplasty.

    Science.gov (United States)

    Weiser, Mitchell C; Moucha, Calin S

    2015-09-01

    The most common pathogens in surgical site infections after total hip and knee arthroplasty are methicillin-sensitive Staphylococcus aureus (MSSA), methicillin-resistant S. aureus (MRSA), and coagulase-negative staphylococci. Patients colonized with MSSA or MRSA have an increased risk for a staphylococcal infection at the site of a total hip or knee arthroplasty. Most colonized individuals who develop a staphylococcal infection at the site of a total hip or total knee arthroplasty have molecularly identical S. aureus isolates in their nares and wounds. Screening and nasal decolonization of S. aureus can potentially reduce the rates of staphylococcal surgical site infection after total hip and total knee arthroplasty.

  18. Comparison of Gait in Patients Following a Computer-Navigated Minimally Invasive Anterior Approach and a Conventional Posterolateral Approach for Total Hip Arthroplasty : A Randomized Controlled Trial

    NARCIS (Netherlands)

    Reininga, Inge H. F.; Stevens, Martin; Wagenmakers, Robert; Boerboom, Alexander L.; Groothoff, Johan W.; Bulstra, Sjoerd K.; Zijlstra, Wiebren

    2013-01-01

    Minimally invasive total hip arthroplasty (MIS THA) aims at minimizing damage to muscles and tendons to accelerate postoperative recovery. Computer navigation allows a precise prosthesis alignment without complete visualization of the bony landmarks during MIS THA. A randomized controlled trial (RCT

  19. Polyethylene sterilization and production affects wear in total hip arthroplasties.

    Science.gov (United States)

    Faris, Philip M; Ritter, Merrill A; Pierce, Andrew L; Davis, Kenneth E; Faris, Gregory W

    2006-12-01

    Production and package sterilization techniques for the polyethylene used in acetabular components for total hip arthroplasties are known to affect wear. We considered three combinations of techniques: sterilization by radiation in inert gas with isostatically molded polyethylene, in inert gas and ram-extruded polyethylene, and in air with extruded polyethylene. The intent of this study was to confirm that molded polyethylene and polyethylene radiated in inert environments reduce wear rates in vivo, to determine the combination of methods with the least wear, and to determine how much variance in wear is attributable to these methods. We reviewed 150 consecutive total hip arthroplasties done in 133 patients using 28-mm cobalt-chrome femoral heads and polyethylene-lined, titanium, ring-locked acetabular components. The least wear occurred in gamma inert-molded polyethylene components. The mean volumetric wear rates were 52.12 mm3/year for gamma inert-molded, 62.32 mm3/year for gamma inert-extruded, and 66.09 mm3/year for gamma air-extruded polyethylene components. Relative risk assessment found gamma air-extruded and gamma inert-extruded polyethylene components to wear 16% and 11% more than gamma inert-molded polyethylene components, respectively. Gender, body mass index, and age accounted for the greatest amount of the explained variance in volumetric wear (57.5%, 21.6%, and 14.4, respectively), followed by angle of wear (3.4%), and sterilization and production technique (3.2%).

  20. Comparison of Acetabular Bone Resection, Offset, Leg Length and Post Operative Function Between Hip Resurfacing Arthroplasty and Total Hip Arthroplasty.

    Science.gov (United States)

    Parry, Michael C; Povey, James; Blom, Ashley W; Whitehouse, Michael R

    2015-10-01

    Controversy exists regarding the amount of acetabular bone resection, biomechanics and function of patients receiving either total hip arthroplasty (THA) or hip resurfacing arthroplasty (HRA). A cohort of patients undergoing 36 mm ceramic-on-ceramic THA (89) or metal-on-metal HRA (86) were compared. No difference was observed when the ratio of native femoral head size was compared to the implanted acetabular component size (1.15 ± 0.1 HRA c.f. 1.13 ± 0.1 THA). No difference was observed in acetabular offset, vertical centre of rotation or function (OHS mean 47 in both groups) but leg length discrepancy (1.8 mm c.f. 5.5 mm) and femoral offset did differ (0.6 mm c.f. 4.1 mm). This demonstrates that 36 mm ceramic-on-ceramic THA is not associated with more bone resection than HRA and achieves equivalent function whilst avoiding the problems of metal-on-metal bearings.

  1. Visual pattern and serial quantitation of {sup 18}F-sodium fluoride PET/CT in asymptomatic patients after hip and knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Son, Hye Joo; Jeong, Young Jin; Yoon, Hyun Jin; Wang, Lih; Kim, Hyeon Jun; Kang, Do Young [Dong-A University Medical Center, Dong-A University College of Medicine, Busan (Korea, Republic of); Park, Jong Hwan [Institute of Convergence Bio-Health, Dong-A University, Busan (Korea, Republic of)

    2016-12-15

    We investigated the visual tracer distribution pattern and serial changes in uptake ratio in different anatomical zones during the natural postoperative course in order to establish a reference for evaluation of patients with complications. A total of 36 patients without symptoms after hip or knee arthroplasty were grouped according to the interval between surgery and the scan. The serial changes in SUVmean in each periprosthetic zone were quantified using the volume of interest isocontour method. Images were classified according to the uptake distribution pattern. The uptake ratios in the postoperative period groups were then compared using the Kruskal-Wallis test. The correlation between uptake ratio and postoperative period was then determined. Tracer distribution patterns in hip prostheses were classified into three types and the patterns in knee prostheses into five types. In hip prostheses, intense osteoblastic activity was observed during 3-6 months and then declined in most patients, but showed a slight increase over 15-25 months in 5-10 % of patients. The correlation coefficients varied among the zones. Significant differences in uptake ratios among the period groups was found for all zones, except zone 8. Porous coated areas showed higher uptake than uncoated areas only for the period the 3-6 months. In knee prostheses, uptake ratios showed a curvilinear pattern, increasing from 3-6 to 8-15 months and declining later. The uptake ratios were different among the period groups. Every zone showed a positive correlation from 3-6 to 8-15 months, and negative correlations from 8-15 to 22-25 months. This is the first {sup 18}F-sodium fluoride PET/CT study investigating the stability of implants and sets a reference for evaluation of patients with complications.

  2. Visual Pattern and Serial Quantitation of (18)F-Sodium Fluoride PET/CT in Asymptomatic Patients After Hip and Knee Arthroplasty.

    Science.gov (United States)

    Son, Hye Joo; Jeong, Young Jin; Yoon, Hyun Jin; Wang, Lih; Kim, Hyeon Jun; Park, Jong-Hwan; Kang, Do-Young

    2016-12-01

    We investigated the visual tracer distribution pattern and serial changes in uptake ratio in different anatomical zones during the natural postoperative course in order to establish a reference for evaluation of patients with complications. A total of 36 patients without symptoms after hip or knee arthroplasty were grouped according to the interval between surgery and the scan. The serial changes in SUVmean in each periprosthetic zone were quantified using the volume of interest isocontour method. Images were classified according to the uptake distribution pattern. The uptake ratios in the postoperative period groups were then compared using the Kruskal-Wallis test. The correlation between uptake ratio and postoperative period was then determined. Tracer distribution patterns in hip prostheses were classified into three types and the patterns in knee prostheses into five types. In hip prostheses, intense osteoblastic activity was observed during 3-6 months and then declined in most patients, but showed a slight increase over 15-25 months in 5-10 % of patients. The correlation coefficients varied among the zones. Significant differences in uptake ratios among the period groups was found for all zones, except zone 8. Porous coated areas showed higher uptake than uncoated areas only for the period the 3-6 months. In knee prostheses, uptake ratios showed a curvilinear pattern, increasing from 3-6 to 8-15 months and declining later. The uptake ratios were different among the period groups. Every zone showed a positive correlation from 3-6 to 8-15 months, and negative correlations from 8-15 to 22-25 months. This is the first (18)F-sodium fluoride PET/CT study investigating the stability of implants and sets a reference for evaluation of patients with complications.

  3. Current concepts, classification, and results in short stem hip arthroplasty.

    Science.gov (United States)

    Falez, Francesco; Casella, Filippo; Papalia, Matteo

    2015-03-01

    Various short hip stems have been introduced with differing implant concepts of femoral fixation and implant length. There is a lack of proper classification for short hip stems, with a clear and accepted definition for implant length and extent of bone preservation in the metaphyseal and diaphyseal femur. This study analyzed the length of short hip stems. Stems were divided into collum, partial collum, and trochanter-sparing implants. An additional category was added, trochanter harming, which was defined as interruption of the circumferential integrity of the femoral neck. For all of the femoral components described, the designs were compared, excluding stems with insufficient clinical data. The 15 finally selected stems were classified as collum (1 stem), partial collum (7 stems), trochanter sparing (4 stems), and trochanter harming (3 stems). Mid-term results (>5 years of follow-up) were available for only 3 designs in the partial collum group. Taking into account the results of short-term studies (<5 years of follow-up), the femoral revision rate per 100 observed component years was <1 for most total hip arthroplasties. However, the studies varied greatly regarding level of significance, and short hip stems without published results are available commercially. Short hip stems cannot be circumscribed by a simple length limit. For some designs, clinical data collected from large patient cohorts showed a survivorship comparable to traditional stems. In cases that must be revised, this often can be performed with a conventional primary stem, fulfilling the promise to preserve bone for potential future revisions in younger patients.

  4. Artroplastia total do quadril não cimentada em pacientes com artrite reumatóide Uncemented total hip arthroplasty in patients with rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Bruno Tavares Rabello

    2008-08-01

    Full Text Available OBJETIVO: Analisar os resultados clínico-funcional e radiográfico das artroplastias totais do quadril não cimentadas em pacientes com artrite reumatóide. MÉTODOS: Estudo retrospectivo de 24 pacientes (28 quadris portadores de artrite reumatóide submetidos à artroplastia total do quadril, utilizando-se a prótese femoral não cimentada Secur Fit Osteonics®, com seguimento mínimo de dois anos. Clinicamente, os pacientes foram avaliados utilizando os critérios de Merle D'Aubigné, e os critérios de Engh, na avaliação radiográfica. RESULTADOS: O tempo médio de seguimento foi de 5,6 anos (dois anos a oito anos e 11 meses. Clinicamente, resultados bons e excelentes foram observados em 22 pacientes, com destaque para a melhora do parâmetro dor. Não foi evidenciado qualquer caso de afrouxamento. Complicações foram observadas em dois casos, um paciente apresentou trombose venosa profunda (TVP, comprovada com doppler, e um caso de fratura peroperatória distal ao calcar, tratada com cerclagem, sem repercussão na qualidade dos resultados clínico e radiográfico do paciente. CONCLUSÃO: Os resultados sugerem, após seguimento médio de 5,6 anos, que a artroplastia total do quadril não cimentada pode ser opção satisfatória nas coxartroses de pacientes portadores de artrite reumatóide.OBJECTIVE: To analyze clinical, functional, and radiographic results of uncemented total hip arthroplasties in patients with rheumatoid arthritis. METHODS: Retrospective study of 24 patients (28 hips with rheumatoid arthritis submitted to total hip arthroplasty, using uncemented femoral prosthesis Secur Fit Osteonics®, with minimum follow-up of two years. The patients were clinically evaluated using the Merle D'Aubigné criteria and the Engh criteria in radiographic evaluation. RESULTS: Mean follow-up time was 5.6 years (two years to eight years and 11 months. Clinically, good and excellent results were observed in 22 patients, with emphasis on pain

  5. Risk Factors for Early Revision after Total Hip Arthroplasty

    Science.gov (United States)

    Dy, Christopher J.; Bozic, Kevin J.; Pan, Ting Jung; Wright, Timothy M.; Padgett, Douglas E.; Lyman, Stephen

    2014-01-01

    Objective Revision total hip arthroplasty (THA) is associated with increased cost, morbidity, and technical challenge compared to primary THA. A better understanding of the risk factors for early revision is needed to inform strategies to optimize patient outcomes. Methods 207,256 patients who underwent primary THA between 1997–2005 in California and New York were identified from statewide databases. Unique patient identifiers were used to identify early revision THA (400 THA annually (p<0.001). Conclusion A number of identifiable factors, including younger age, Medicaid, and low hospital volume increase the risk of undergoing early revision THA. Patient-level characteristics distinctly affect the risk of revision within 10 years, particularly if due to infection. Our findings reinforce the need for continued investigation of the predictors of early failure following THA. PMID:24285406

  6. The Exeter Contemporary flanged cemented acetabular component in primary total hip arthroplasty.

    Science.gov (United States)

    Maggs, J L; Smeatham, A; Whitehouse, S L; Charity, J; Timperley, A J; Gie, G A

    2016-03-01

    We report on the outcome of the Exeter Contemporary flanged cemented all-polyethylene acetabular component with a mean follow-up of 12 years (10 to 13.9). This study reviewed 203 hips in 194 patients. 129 hips in 122 patients are still in situ; 66 hips in 64 patients were in patients who died before ten years, and eight hips (eight patients) were revised. Clinical outcome scores were available for 108 hips (104 patients) and radiographs for 103 hips (100 patients). A retrospective review was undertaken of a consecutive series of 203 routine primary cemented total hip arthroplasties (THA) in 194 patients. There were no acetabular component revisions for aseptic loosening. Acetabular revision was undertaken in eight hips. In four hips revision was necessitated by periprosthetic femoral fractures, in two hips by recurrent dislocation, in one hip for infection and in one hip for unexplained ongoing pain. Oxford and Harris hip scores demonstrated significant clinical improvement (all p acetabular components available for radiological evaluation. In 27 of these, the line was confined to zone 1. No component had migrated. Kaplan-Meier survivorship, with revision for aseptic loosening as the endpoint, was 100% at 12.5 years and for all causes was 97.8% (95% confidence interval 95.6 to 100) when 40 components remained at risk. The Exeter Contemporary flanged cemented acetabular component demonstrates excellent survivorship at 12.5 years. The Exeter Contemporary flanged cemented acetabular component has excellent clinical outcomes and survivorship when used with the Exeter stem in total hip arthroplasty. ©2016 The British Editorial Society of Bone & Joint Surgery.

  7. Health-related quality of life in veterans with prevalent total knee arthroplasty and total hip arthroplasty

    OpenAIRE

    Singh, J.A.; Sloan, J.A.

    2008-01-01

    Objective. To study the HRQOL in veterans with prevalent total knee arthroplasty (TKA) or total hip arthroplasty (THA) and compare them with age- and gender-matched US population and control veteran population without these procedures.

  8. Psychological factors as risk factors for poor hip function after total hip arthroplasty

    Science.gov (United States)

    Benditz, Achim; Jansen, Petra; Schaible, Jan; Roll, Christina; Grifka, Joachim; Götz, Jürgen

    2017-01-01

    Recovery after total hip arthroplasty (THA) is influenced by several psychological aspects, such as depression, anxiety, resilience, and personality traits. We hypothesized that preoperative depression impedes early functional outcome after THA (primary outcome measure). Additional objectives were perioperative changes in the psychological status and their influence on perioperative outcome. This observational study analyzed depression, anxiety, resilience, and personality traits in 50 patients after primary unilateral THA. Hip functionality was measured by means of the Harris Hip Score. Depression, state anxiety, and resilience were evaluated preoperatively as well as 1 and 5 weeks postoperatively. Trait anxiety and personality traits were measured once preoperatively. Patients with low depression and anxiety levels had significantly better outcomes with respect to early hip functionality. Resilience and personality traits did not relate to hip functionality. Depression and state anxiety levels significantly decreased within the 5-week stay in the acute and rehabilitation clinic, whereas resilience remained at the same level. Our study suggests that low depression and anxiety levels are positively related to early functionality after THA. Therefore, perioperative measurements of these factors seem to be useful to provide the best support for patients with risk factors.

  9. Two-Stage Progressive Femoral Lowering Followed by Cementless Total Hip Arthroplasty for Treating Crowe IV-Hartofilakidis Type 3 Developmental Dysplasia of the Hip.

    Science.gov (United States)

    Binazzi, Roberto

    2015-05-01

    High developmental dysplasia of the hip is commonly treated with total hip arthroplasty and shortening osteotomy. We present a two stage technique, consisting of progressive femoral lowering followed by total hip arthroplasty. The clinico-radiographic results of eleven patients (twelve hips) who were operated on with the two-stage technique were evaluated at a mean follow-up of 11 ± 5 years. At the final follow-up, ten patients (eleven hips) had a mean Harris hip score of 85 ± 5 points with no implant loosening. One patient (one hip) was revised at 5 years due to infection. No neurovascular complications were observed in any patients. With this technique, we could place the cup in the anatomical position and obtain complete limb symmetry with excellent clinical results at long-term. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Accuracy of CT-guided joint aspiration in patients with suspected infection status post-total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Tomas, Xavier; Garcia-Diez, Ana Isabel; Pomes, Jaime [Universidad de Barcelona, Department of Radiology, Hospital Clinic, Barcelona (Spain); Bori, Guillem; Garcia, Sebastian; Gallart, Xavier; Martinez, Juan Carlos; Riba, Josep [Universidad de Barcelona, Department of Orthopaedics, Hospital Clinic, Barcelona (Spain); Soriano, Alex; Mensa, Josep [Universidad de Barcelona, Department of Infectious Diseases, Hospital Clinic, Barcelona (Spain); Rios, Jose [Statistical Unit de Suport a la Estadistica I Metodologia IDIBAPS, Barcelona (Spain); Almela, Manel [Universidad de Barcelona, Department of Microbiology, Hospital Clinic, Barcelona (Spain)

    2011-01-15

    To determine the accuracy of guided computed tomography aspiration in the detection of septic hip prosthesis before surgery. Sixty-three patients (35 women and 28 men; age range, 29-86 years; mean age, 71 years) with clinically suspected septic hip prosthesis were prospectively studied with independent review board (IRB) approval. Volume and microbiological cultures of aspirated fluid and several computed tomography imaging findings such as periprosthetic fluid collections, prosthetic acetabular malposition, and heterotopic ossification were analyzed. All patients underwent revision surgery and infection was finally diagnosed in 33 patients. Statistical comparative analysis was performed comparing computed tomography aspiration and surgical findings (95% CI; level of significance at P = 0.05 two-sided) with 70% sensitivity, 100% specificity, 84% accuracy, 100% positive predictive value, and 75% negative predictive value. Using Fisher's exact test, the presence of periprosthetic fluid collections (P = 0.001), prosthetic acetabular malposition (P = 0.025) and aspirated fluid volume (P = 0.009) were significantly higher in infected than in non-infected prostheses, whereas heterotopic ossification was not (P = 0.429). Computed tomography aspiration is accurate to preoperatively diagnose septic hip prosthesis on the basis of volume and bacterial cultures of aspirated joint fluid. Furthermore, imaging findings such as periprosthetic fluid collections and prosthetic acetabular malposition strongly suggest infected prosthesis. (orig.)

  11. MRI of asymptomatic patients with metal-on-metal and polyethylene-on-metal total hip arthroplasties

    Energy Technology Data Exchange (ETDEWEB)

    Mistry, A.; Cahir, J. [Department of Radiology, Norfolk and Norwich University Hospital, Norwich, Norfolk (United Kingdom); Donell, S.T.; Nolan, J. [Department of Orthopaedic Surgery, Norfolk and Norwich University Hospital, Norwich, Norfolk (United Kingdom); Toms, A.P., E-mail: andoni.toms@nnuh.nhs.u [Department of Radiology, Norfolk and Norwich University Hospital, Norwich, Norfolk (United Kingdom)

    2011-06-15

    Aims: To define and compare magnetic resonance imaging (MRI) findings of asymptomatic patients with metal-on-metal (MOM) and polyethylene-on-metal (POM) total hip replacements (THRs). Materials and methods: Twenty-two THRs in 20 asymptomatic patients (seven men, 13 women, mean age 68 years, range 47-86 years) with normal hip radiographs were included in the study. These comprised 10 POM and 12 MOM bearings. Each patient underwent MRI with metal artefact reduction sequences (MARS) at a mean time of 46 months (POM) and 70 months (MOM) after surgery. Two musculoskeletal radiologists independently read each MRI examination for fluid collections, soft-tissue masses, muscle atrophy, and bone marrow signal changes. Results: A pre-MRI hip radiograph showed no significant differences from the postoperative radiograph regarding acetabular inclination, femoral stem angle, and stem mantle grade. There were eight periprosthetic collections (one POM, seven MOM). The majority of THRs had normal gluteal muscles. The ipsilateral piriformis and obturator internus muscles were more frequently abnormal in the MOM group. Overall, there were no significant differences in the number of abnormalities between the two types of bearings. Conclusion: A range of MRI abnormalities are present in normal asymptomatic THRs but the increased frequency of these associated with MOM THR suggest that some of these changes might represent subclinical disease.

  12. Effectiveness of physiotherapy exercise following hip arthroplasty for osteoarthritis: a systematic review of clinical trials

    OpenAIRE

    Barker Karen L; Minns Lowe Catherine; Dewey Michael E; Sackley Catherine M

    2009-01-01

    Abstract Background Physiotherapy has long been a routine component of patient rehabilitation following hip joint replacement. The purpose of this systematic review was to evaluate the effectiveness of physiotherapy exercise after discharge from hospital on function, walking, range of motion, quality of life and muscle strength, for osteoarthritic patients following elective primary total hip arthroplasty. Methods Design: Systematic review, using the Cochrane Collaboration Handbook for System...

  13. Metallic Modular Taper Junctions in Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Timothy McTighe

    2015-08-01

    Full Text Available The emergence of modularity in total hip arthroplasty (THA in the 1980s and 1990s was based on the fact that the benefit of these design features outweighed the risk. The use of metallic modular junctions presents a unique set of advantages and problems for use in THA. The advantages include improvement in fit and fill of the implant to bone, restoration of joint mechanics, reduced complications in revision surgery and reduction of costly inventory. However, the risks or concerns are a little harder to identify and deal with. Certainly corrosion, and fatigue failure are the two most prevalent concerns but now the specifics of fretting wear and corrosive wear increasing particulate debris and the potential biological response is having an impact on the design and potential longevity of the reconstructed hip. Material and designs are facing a shorter life expectancy than what was previously thought, mostly due to an increasing level of physical activity by the patient. Because there are no accurate laboratory test whereby the service life and performance of these implants can be predicted, early controlled clinical evaluations are necessary. Early publication of testing and clinical impressions should be encouraged in an attempt to reduce exposure to potential at risk patients, implants and material. The reduction and possible elimination of risks will require a balancing of all the variables requiring a multidisciplinary endeavor. This paper is designed to review the risk factors, and benefits of modular junctions in total hip arthroplasty (THA. Also some basic engineering principals that can reduce risk factors and improve functionality of modular junctions.

  14. Recovery after short-stay total hip and knee arthroplasty. Evaluation of a support program and outcome determination

    NARCIS (Netherlands)

    Akker-Scheek, Inge van den

    2007-01-01

    As a result of the increasing demand for total hip arthroplasties (THA) and total knee arthroplasties (TKA), waiting lists are growing. To cope with this problem, many hospitals have introduced short-stay programs; a consequence is increased responsibility of the patient regarding his own rehabilita

  15. The "true" incidence of surgically treated deep prosthetic joint infection after 32,896 primary total hip arthroplasties

    DEFF Research Database (Denmark)

    Gundtoft, Per Hviid; Overgaard, Søren; Schønheyder, Henrik Carl;

    2015-01-01

    BACKGROUND AND PURPOSE: It has been suggested that the risk of prosthetic joint infection (PJI) in patients with total hip arthroplasty (THA) may be underestimated if based only on arthroplasty registry data. We therefore wanted to estimate the "true" incidence of PJI in THA using several data...

  16. A Large Rice Body-Containing Cyst Mimicking Infection following Total Hip Arthroplasty: A Case Report

    Directory of Open Access Journals (Sweden)

    Wael Bayoud

    2017-01-01

    Full Text Available Introduction. Soft tissue mass following total hip arthroplasty raises several differential diagnoses not limited to infection, hematoma, wear debris, malignancy, and bursitis. Rice body formation in the hip region is an uncommon process denoting a chronic inflammation. We report here the second case of its kind in the medical literature of a wide symptomatic rice-like body cyst complicating a total hip arthroplasty. Case Presentation. This is the case of an 82-year-old white female, presenting with a warm, red, and inflated groin five years after revision of right total hip arthroplasty. Surgical intervention reveals a large well circumscribed cyst containing well-organized rice-like bodies. This eventuality was never reported in differential diagnosis of hip periprosthetic soft tissue masses before. Conclusion. This case report helps widening the array of the differential diagnosis in patients presenting with a slow growing soft tissue mass following total hip arthroplasty, making rice-like bodies cyst a valid one to consider.

  17. A randomised, controlled clinical study on total hip arthroplasty using 4 different bearings

    DEFF Research Database (Denmark)

    Borgwardt, Arne; Zerahn, Bo; Fabricius, Sandra D

    2017-01-01

    PURPOSE: To compare 4 different bearings in total hip arthroplasty (THA) in a randomised controlled clinical study on clinical performance. METHODS: 393 patients with osteoarthritis of the hip or avascular necrosis were included and allocated to 1 of the head-and-cup couples zirconia-on-polyethyl......PURPOSE: To compare 4 different bearings in total hip arthroplasty (THA) in a randomised controlled clinical study on clinical performance. METHODS: 393 patients with osteoarthritis of the hip or avascular necrosis were included and allocated to 1 of the head-and-cup couples zirconia...... cumulated prosthesis survival percentages and 95% confidence interval after 10 years were: group A 84.6 (75.8-93.4); group B 95.0 (89.5-100); group C 93.2 (86.7-99.7); group D 66.1 (54.5-77.7). The patients' physical function was significantly improved and remained equally good in all 4 groups, however...

  18. Similar range of motion and function after resurfacing large-head or standard total hip arthroplasty

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Ovesen, Ole; Varmarken, Jens-Erik

    2013-01-01

    BACKGROUND AND PURPOSE: Large-size hip articulations may improve range of motion (ROM) and function compared to a 28-mm THA, and the low risk of dislocation allows the patients more activity postoperatively. On the other hand, the greater extent of surgery for resurfacing hip arthroplasty (RHA) c...... for large articulations did not improve the clinical and patient-perceived outcomes. The more extensive surgical procedure of RHA did not impair the rehabilitation. This project is registered at ClinicalTrials.gov under # NCT01113762.......BACKGROUND AND PURPOSE: Large-size hip articulations may improve range of motion (ROM) and function compared to a 28-mm THA, and the low risk of dislocation allows the patients more activity postoperatively. On the other hand, the greater extent of surgery for resurfacing hip arthroplasty (RHA...

  19. No dislocations after primary hip arthroplasty with the dual mobility cup in displaced femoral neck fracture in patients with dementia. A one-year follow-up in 20 patients

    Directory of Open Access Journals (Sweden)

    Graversen Anders Elneff

    2017-01-01

    Full Text Available Purpose: The aim of this study was to describe the dislocation rates, reoperation rates and mortality 30 day and one year following THA with AVANTAGE® dual mobility cup among dementia patients with an acute displaced intracapsular femoral neck fracture. Patients and methods: From 2010 to 2014 we identified 20 hip fracture patients with dementia, who have had total hip arthroplasty with the AVANTAGE® dual mobility cup. The primary outcome was dislocation. Secondary outcomes were revision surgery, 30 days and one year mortality, time to surgery and length of hospital stay. Results: Follow-up time was one year. None of the patients experienced dislocation or received revision surgery in the follow-up period. The 30-days mortality rate was 25% (confidence interval (CI 95%; 4–46% and the one year mortality was 45% (CI 95%; 21–69. Mean time to surgery was 27 h (CI 95%; 20–37 h and mean length of hospital stay was 5.5 days (CI 95%; 4, 0–7, 6 days. Conclusion: THA with the dual-mobility cup seems favourable in the treatment of patients with a displaced femoral neck fracture and patients with dementia. Correct placement of the cup is pivotal and technically demanding. Not all orthopedic surgeons perform total hip arthroplasty while challenges regarding the logistics can be encountered since time to surgery is known to affect the mortality negatively.

  20. Early morbidity after aseptic revision hip arthroplasty in Denmark

    DEFF Research Database (Denmark)

    Lindberg-Larsen, M.; Hansen, Torben Bæk

    2014-01-01

    aseptic revision THRs from 1st October 2009 to 30th September 2011 using the Danish National Patient Registry, with additional information from the Danish Hip Arthroplasty Registry. There were 1553 procedures (1490 patients) performed in 40 centres and we divided them into total revisions, acetabular...... component revisions, femoral stem revisions and partial revisions. The mean age of the patients was 70.4 years (25 to 98) and the median hospital stay was five days (interquartile range 3 to 7). Within 90 days of surgery, the readmission rate was 18.3%, mortality rate 1.4%, re-operation rate 6.......1%, dislocation rate 7.0% and infection rate 3.0%. There were no differences in these outcomes between high- and low-volume centres. Of all readmissions, 255 (63.9%) were due to 'surgical' complications versus 144 (36.1%) 'medical' complications. Importantly, we found no differences in early morbidity across...

  1. Early postoperative acetabular discontinuity after total hip arthroplasty.

    Science.gov (United States)

    Desai, Gaurav; Ries, Michael D

    2011-12-01

    Periprosthetic acetabular fracture is a rare complication after total hip arthroplasty (THA). However, we have treated 2 patients with acute postoperative acetabular discontinuity that occurred 2 and 3 weeks after primary THA. Both fractures were in elderly osteoporotic female patients with minimal trauma and may have developed from unrecognized intraoperative fractures. Pelvic stability was restored with acetabular revision using medial morselized bone grafting and a cemented reconstruction cage. This report demonstrates that early postoperative periprosthetic acetabular discontinuity after THA is a risk in elderly patients with severe osteoporosis and that salvage of acetabular fixation can be achieved with cemented cage reconstruction and medial morselized bone grafting. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Femoral component loosening after hip resurfacing arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Zustin, Jozef; Sauter, Guido [University Medical Centre Hamburg-Eppendorf, Institute of Pathology, Hamburg (Germany); Hahn, Michael [University Medical Centre Hamburg-Eppendorf, Center for Biomechanics and Skeletal Biology, Hamburg (Germany); Morlock, Michael M. [TUHH Hamburg University of Technology, Biomechanics Section, Hamburg (Germany); Ruether, Wolfgang [University Medical Centre Hamburg-Eppendorf, Department of Orthopaedics, Hamburg (Germany); Amling, Michael [University Medical Centre Hamburg-Eppendorf, Center for Biomechanics and Skeletal Biology, Hamburg (Germany); University Medical Centre Hamburg-Eppendorf, Department of Trauma, Hand and Reconstructive Surgery, Hamburg (Germany)

    2010-08-15

    Before the re-introduction of the current generation of total hip resurfacing arthroplasty, component loosening and osteolysis were of great concern to the orthopaedic community. Early, mid- and long-term clinical results are encouraging, but component loosening still exists. Macroscopic, contact radiographic and histopathological analyses after undecalcified preparation of bone tissue specimens were performed. To investigate the frequency and morphological patterns of the loosening of the femoral component, we analysed a series of 190 retrieved femoral remnants that were revised for aseptic failures. Thirty-five (18.4%) hips were revised for clinical and/or radiographic loosening of the femoral component. Pseudoarthrosis (n = 17; median in situ time: 16 weeks, interquartile range [IQR]: 9 to 34), collapsed osteonecrosis (n = 5; median in situ time: 79 weeks, IQR: 63 to 97), cement-socket debonding (n = 3; median in situ time: 89 weeks, IQR: 54 to 97) and at later follow-up bone-cement loosening (n = 10; median in situ time: 175 weeks; IQR 112 to 198; p =0.005) were distinct patterns of the femoral remnant-implant loosening. Fibrocartilaginous metaplasia of interface bone trabeculae (n = 38; median in situ time: 61 weeks, IQR: 32 to 138) was strongly associated with femoral component loosening (p = 0.009). Both the trabecular hyperosteoidosis (n = 32; median in situ time: 71 weeks, IQR 50 to 129) and excessive intraosseous lymphocyte infiltration (n = 12; median in situ time: 75 weeks, IQR 51 to 98) at the bone-cement interface correlated strongly with fibrocartilaginous metaplasia (p = 0.001 and p = 0.016 respectively) and all three lesions were associated with the female gender (p = 0.021, p = 0.009, and p = 0.051). Femoral component loosening at early follow-up was mostly caused by pathological changes of the femoral remnant bone tissue: pseudoarthrosis and collapsed osteonecrosis. Fibrocartilaginous metaplasia was frequently observed in hips with femoral

  3. Quality of life following total hip arthroplasty in patients with acetabular fractures, previously managed by open reduction and internal fixation

    Institute of Scientific and Technical Information of China (English)

    Prasoon Kumar; Ramesh Kumar Sen; Vishal Kumar; Ankit Dadra

    2016-01-01

    Purpose:Total hip replacement (THR) is one of the most successful and cost-effective surgical procedures and remains the treatment of choice for long-term pain relief and restoration of function for patients with diseased or damaged hips.Acetabular fractures managed either conservatively or operatively by fixation tend to present later with secondary joint changes that require THR.In this study we evaluated the functional outcome and quality of life achieved by such patients.Methods:Our study was carried out as a retrospective trial by recruiting patients who underwent THR from June 2006 to May 2012.A total of 32 patients were included with a mean age of 46.08 years ranging from (25-65) years.We evaluated the quality of life in the patients using scoring techniques of Short Musculoskeletal Functional Assessment (SMFA) and the 12-Item Short Form Health Survey (SF-12).Functional outcome was assessed using Harris Hip Score (HHS).Results:The mean HHS of the patients was 84.3 with a range from 56 to 100.The SMFA averaged 13.3.The SF-12 score averaged 49.1.The correlation of the HHS with SF-12 was positive (p =0.001) while with SMFA there was a negative correlation (p =0.001).Conclusion:From this study it is inferred that the functional outcome of THR and quality of life in patients who had acetabular fractures and were initially managed by open reduction and internal fixation is good.

  4. The innovation trap: modular neck in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Samo Karel Fokter

    2017-04-01

    Full Text Available Background: Innovations play the key role in the success of orthopaedic surgery. However, even minor modifications in the established concepts and proven designs may result in disasters. The endemic of modular femoral neck fracture (24 cases of about 4000 implanted in fully modular total hip arthroplasty, popular in our country for the last 20 years, seems to challenge us with such an unfortunate consequences. The aim of this report was to analyze the extent and the causes of the problem on the one hand and to propose possible solutions on the other.Methods: Literature search for problems associated with Profemur Z (or earlier versions with the same taper-cone design fully-modular femoral stem made of titanium alloy (Ti6Al4V was performed, and hip arthroplasty registries were searched to evaluate the failure rates of the mentioned design. Mechanisms of failure were studied to get in-depth understanding of this particular hip reconstruction device.Results: Since 2010 onwards, several case reports on catastrophic modular femoral neck fractures of Profemur Z were published. Te frst Slovenian case was described in 2012. The first two larger series with modular femoral neck fractures were published in 2016. Te Australian Joint Replacement Registry was the first to discover increased revision rates due to fractures of this hip reconstruction system. Public Agency of the Republic of Slovenia for Medicinal Products and Medical Devices (JAZMP received frst two reports regarding Profemur Z modular neck complication from abroad in 2010, the first Slovenian report was received in 2012, and altogether 7 reports from Slovenian hospitals were received until December 2016. Corrosion at the neck-taper interface, where two equal or different materials are subject to constant wear in the presence of body fluids, is assumed to be responsible for the unacceptable high failure rate.Conclusions: Manufacturers are responsible to produce and market only safe devices

  5. Readmissions after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B

    2010-01-01

    With the implementation of fast-track surgery with optimization of both logistical and clinical features, the postoperative convalescence has been reduced as functional milestones have been achieved earlier and consequently length of stay (LOS) in hospital has been reduced. However, it has been s...... speculated that a decrease in LOS may be associated with an increase in readmissions in general, including risk of dislocation after total hip arthroplasty (THA) or manipulation after total knee arthroplasty (TKA)....

  6. Formation of a pseudotumor in total hip arthroplasty using a tribological metal–polyethylene pair☆

    Science.gov (United States)

    Fagotti, Lorenzo; Vicente, José Ricardo Negreiros; Miyahara, Helder Souza; de Oliveira, Pedro Vitoriano; Bernabé, Antônio Carlos; Croci, Alberto Tesconi

    2015-01-01

    The aim here was to report a case of a young adult patient who evolved with tumor formation in the left thigh, 14 years after revision surgery on hip arthroplasty. Davies in 2005 made the first description of this disease in patients undergoing metal-on-metal hip arthroplasty. Over the last decade, however, pseudotumors around metal-on-polyethylene surfaces have become more prevalent. Our patient presented with increased volume of the left thigh 8 years after hip arthroplasty revision surgery. Two years before the arising of the tumor in the thigh, a nodule in the inguinal region was investigated to rule out a malignant neoplastic process, but the results were inconclusive. The main preoperative complaints were pain, functional limitation and marked reduction in the range of motion of the left hip. Plain radiographs showed loosening of acetabular and femoral, and a large mass between the muscle planes was revealed through magnetic resonance imaging of the left thigh. The surgical procedure consisted of resection of the lesion and removal of the components through lateral approach. In respect of total hip arthroplasty, pseudotumors are benign neoplasms in which the bearing surface consists of metal-on-metal, but they can also occur in different tribological pairs, as presented in this case. PMID:27218090

  7. Inter-tester Reliability of the Hand-held dynamometer and the Leg Extensor Power Rig applied on Patients after Total Hip Arthroplasty

    DEFF Research Database (Denmark)

    Mikkelsen, Lone Ramer; Mechlenburg, Inger; Petersen, Annemette Krintel

    INTRODUCTION: Rehabilitation has an increasing focus on intensive resistance training early after joint replacement (1,2). This increases the requests for measuring changes in the muscle strength and muscle power over time. Hand-held dynamometer (HHD) is a device used to measure isometric muscle...... strength and Leg Extensor Power Rig (LEPR) is a tool for measuring muscle power. OBJECTIVES: To test the inter-tester reliability of the HHD in hip abduction and the LEPR in Total Hip Arthroplasty (THA) patients. METHODS: Two groups each consisting 20 subjects were included. Mean age was 68.4 years. All...... the two testers (p=0.62) and the two tests (0.14); ICC=0.91 (95% CI: 0.79;0.96); LOA=±34Watt. CONCLUSION: The relative reliability was acceptable for both HHD and LEPR. The absolute reliability showed that a change in the muscle strength/power above 18 Newton or 34 Watt can be counted as a real change...

  8. Similar incidence of periprosthetic fluid collections after ceramic-on-polyethylene total hip arthroplasties and metal-on-metal resurfacing arthroplasties: results of a screening metal artefact reduction sequence-MRI study

    NARCIS (Netherlands)

    Bisseling, P.; Wit, B.W. de; Hol, A.M.; Gorp, M.J. van; Kampen, A. van; Susante, J.L. van

    2015-01-01

    Patients from a randomised trial on resurfacing hip arthroplasty (RHA) (n = 36, 19 males; median age 57 years, 24 to 65) comparing a conventional 28 mm metal-on-metal total hip arthroplasty (MoM THA) (n = 28, 17 males; median age 59 years, 37 to 65) and a matched control group of asymptomatic patien

  9. Preoperative progressive explosive-type resistance training is feasible and effective in patients with hip osteoarthritis scheduled for total hip arthroplasty

    DEFF Research Database (Denmark)

    Hermann, A; Holsgaard-Larsen, A; Zerahn, B;

    2016-01-01

    pain (VAS score ≤ 5) reported in 83% of sessions and no adverse events. Changes in HOOS 'function' was 10.0 points 95%CI [4.7; 15.3] higher in IG compared to CG (P leg extension muscle power (P ... in the Hip Osteoarthritis Outcome Score (HOOS) (primary endpoint; ADL function), and leg muscle power at post intervention follow-up immediate before surgery. Intention-to-treat analyses were performed in a multilevel regression model adjusting for baseline, sex, age and weight. Feasibility was reported.......0001) compared to CG. CONCLUSION: Progressive explosive-type RT was feasible in the included group of hip OA patients scheduled for THA and resulted in significant improvement in self-reported outcomes and increased leg muscle power....

  10. Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty : design of a randomized controlled trial

    NARCIS (Netherlands)

    Zijlstra, Wierd P.; Bos, Nanne; van Raaij, Jos J. A. M.

    2008-01-01

    Background: Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyet

  11. Functional and radiographic evaluation and quality of life analysis after cementless total hip arthroplasty with ceramic bearings: minimum of 5 years follow-up

    OpenAIRE

    Rafael Borghi Mortat; Rafael Mota Marins dos Santos; Lucas Borghi Mortati; Rodrigo Angeli; Ramon Candeloro; Richard Armelin Borger; Roberto Dantas Queiroz

    2013-01-01

    Objective: The aim of the study is to analyze and correlate functional and radiographic results and quality of life in patients undergoing cementless total hip arthroplasty with ceramic surface, performed at Hospital Servidor Publico de Sao Paulo from 2001 to 2006. Methods: We retrospectively analyzed 35 hips treated with cementless total hip arthroplasty with ceramic surfaces with a minimum follow-up of 5 years. Functional evaluation was based on the Harris Hip Score (HHS). Radiographic...

  12. Digital templating in primary total hip and knee arthroplasty.

    Science.gov (United States)

    Levine, Brett; Fabi, David; Deirmengian, Carl

    2010-11-02

    The use of digital radiography is becoming more prevalent in orthopedics. This transition impacts the ability to preoperatively plan for implants in total hip arthroplasty (THA) and total knee arthroplasty (TKA). This article reports on the clinical success of digital templating using the Advanced Case Plan (Stryker Imaging, Flower Mound, Texas) system in primary THA and TKA. Digital radiographs of 269 consecutive patients undergoing primary THA (93 cases) or TKA (176 cases) were templated using the Advanced Case Plan digital software package. A 25.4-mm metallic sphere was used as a calibrating marker. Anteroposterior hip and lateral knee radiographs were digitally templated preoperatively and compared to the actual size of the implants at the time of surgery. The accuracy of calibrating images using the metallic sphere was validated by measuring the diameter of femoral heads on 25 postoperative hip radiographs. Digital templating was accurate in predicting the correct implant size in 58.5% of THAs and 66% of TKAs. In 93% of THAs and 98.5% of TKAs, preoperative templating was within 1 size of the final implant. There were no cases in which the predicted implant size varied from the final components by >2 sizes. Calibrating the image using the metallic sphere marker was found to be highly accurate, predicting the correct femoral head size within 1.5 mm in all 25 cases (7 hemiarthroplasties and 18 THAs). Digital templating is an effective means for predicting the size of THA and TKA components, thus remaining a viable option as we transition into the modern era of digital radiography. Future studies will evaluate interobserver reliability and the impact of level of training on templating accuracy. Copyright 2010, SLACK Incorporated.

  13. A prospective randomised study of periprosthetic femoral bone remodeling using four different bearings in hybrid total hip arthroplasty

    DEFF Research Database (Denmark)

    Zerahn, Bo; Borgwardt, Lotte; Ribel-Madsen, Søren

    2011-01-01

    Abstract: We performed a study to assess whether different bearing materials have an impact on femoral bone remodeling within the first four years after a hybrid total hip arthroplasty. 205 of 300 patients were available for 4 years follow-up after being randomly allocated to four prosthetic...... 1, 6, and 7.Bone remodeling after total hip arthroplasty may depend on the composition of bearing materials, but age, height, weight, and stem size are also related to changes in BMD....

  14. Poor 10-year survivorship of hip resurfacing arthroplasty

    Science.gov (United States)

    Seppänen, Matti; Karvonen, Mikko; Virolainen, Petri; Remes, Ville; Pulkkinen, Pekka; Eskelinen, Antti; Liukas, Antti; Mäkelä, Keijo T

    2016-01-01

    Background and purpose In a previous registry report, short-term implant survival of hip resurfacing arthroplasty (HRA) in Finland was found to be comparable to that of total hip arthroplasty (THA). Since then, it has become evident that adverse reactions to metal debris (ARMDs) may also be associated with HRA, not only with large-diameter head metal-on-metal THA. The aim of the study was to assess medium- to long-term survivorship of HRA based on the Finnish Arthroplasty Register (FAR). Patients and methods 5,068 HRAs performed during the period 2001–2013 in Finland were included. Kaplan-Meier survival analysis was used to calculate survival probabilities and their 95% confidence intervals (CIs). Cox multiple regression, with adjustment for age, sex, diagnosis, femoral head size, and hospital volume was used to analyze implant survival of HRA devices with revision for any reason as endpoint. The reference group consisted of 6,485 uncemented Vision/Bimetric and ABG II THAs performed in Finland over the same time period. Results The 8-year survival, with any revision as an endpoint, was 93% (CI: 92–94) for Birmingham Hip Resurfacing (BHR), 86% (CI: 78–94) for Corin, 91% (CI: 89–94) for ReCap, 92% (CI: 89–96) for Durom, and was 72% (CI: 69–76) for the Articular Surface Replacement (ASR). The 10-year survival, with any revision as an endpoint, for reference THAs was 92% (CI: 91–92) and for all HRAs it was 86% (CI: 84–87%). Female HRA patients had about twice the revision risk of male patients. ASR had an inferior outcome: the revision risk was 4-fold higher than for BHR, the reference implant. Interpretation The 10-year implant survival of HRAs is 86% in Finland. According to new recommendations from NICE (The National Institute for Health and Care Excellence), an HRA/THA should have a revision rate of 5% or less at 10 years. None of the HRAs studied achieved this goal. PMID:27759474

  15. Early Outcomes of Primary Total Hip Arthroplasty for Osteonecrosis of the Femoral Head in Patients with Human Immunodeficiency Virus in China

    Directory of Open Access Journals (Sweden)

    Chang-Song Zhao

    2015-01-01

    Full Text Available Background: Studies have reported that patients with human immunodeficiency virus (HIV have a high incidence of osteonecrosis of the femoral head (ONFH. Total hip arthroplasty (THA is an effective management of ONFH. However, little data exist regarding the use of THA for the HIV patients with ONFH in China. This study reviewed the outcomes of HIV-positive patients who underwent THA for ONFH, compared with HIV-negative individuals. Methods: The patients who underwent THA for ONFH from September 2012 to September 2014 in Beijing Ditan Hospital, Capital Medical University were retrospectively studied. Twenty-eight HIV-positive patients and 35 HIV-negative patients underwent 48 THAs and 45 THAs with cementless components, respectively. Medical records and follow-up data were reviewed. Harris Hip Score (HHS was applied to evaluate the pain and function of the hips before and after THA. Complications such as wound healing, surgical site infection, deep venous thrombosis, pulmonary embolism, sepsis, mortality, and complications from the prosthesis were reviewed. The operation time, blood loss, and hospital stay were compared between the two groups. Results: The mean follow-up period was 19.5 ± 5.8 months (ranging from 6 to 30 months. The mean age of the HIV-positive patients with osteonecrosis at the time of surgery was 35 years old, which was significantly lower than that of the HIV-negative group (42 years old (P 0.05. The HHSs of two groups significantly improved after THAs (P < 0.05, without significant difference between two groups. No wound complication, sepsis, mortality, prosthesis complication, and occupational exposure occurred, except for two cases of heterotopic ossification and one case of humeral head necrosis. Conclusions: ONFH is more likely to occur bilaterally in younger HIV-positive males. The development of osteonecrosis seems faster in HIV-positive patients than in HIV-negative patients. This should be cautionary for asymptomatic

  16. Mean 5-Year Clinical and Radiographic Outcomes of Cementless Total Hip Arthroplasty in Patients under the Age of 30

    Directory of Open Access Journals (Sweden)

    Jeremy M. Gililland

    2013-01-01

    Full Text Available We performed a retrospective review of 40 consecutive modern cementless THAs with 65-month mean followup in 34 patients under the age of 30 primarily for diagnoses other than inflammatory arthritis. We found acceptable functional improvement and radiographic outcomes at mean 5-year followup. We found a high transfusion rate, dislocation rate (10%, and midterm overall aseptic revision rate (17%. Twenty-eight (67.5% of hips in this series were metal on metal, with a large percentage of aseptic revisions related to metallosis (57%. When revisions due to metallosis were excluded, the aseptic revision rate was 7.5%. The high prevalence of prior pediatric hip surgery in these patients (50% may predispose to increased technical difficulty resulting in increased complications and higher revision rates. Although our revision rate was high in these young patients, it is favorable compared to older techniques and consistent with the limited data available with modern cementless techniques in patients of similar age. Cementless THA with modern designs remains a viable option for the treatment of arthritis in the young patient.

  17. Can consistent benchmarking within a standardized pain management concept decrease postoperative pain after total hip arthroplasty? A prospective cohort study including 367 patients

    Science.gov (United States)

    Benditz, Achim; Greimel, Felix; Auer, Patrick; Zeman, Florian; Göttermann, Antje; Grifka, Joachim; Meissner, Winfried; von Kunow, Frederik

    2016-01-01

    Background The number of total hip replacement surgeries has steadily increased over recent years. Reduction in postoperative pain increases patient satisfaction and enables better mobilization. Thus, pain management needs to be continuously improved. Problems are often caused not only by medical issues but also by organization and hospital structure. The present study shows how the quality of pain management can be increased by implementing a standardized pain concept and simple, consistent, benchmarking. Methods All patients included in the study had undergone total hip arthroplasty (THA). Outcome parameters were analyzed 24 hours after surgery by means of the questionnaires from the German-wide project “Quality Improvement in Postoperative Pain Management” (QUIPS). A pain nurse interviewed patients and continuously assessed outcome quality parameters. A multidisciplinary team of anesthetists, orthopedic surgeons, and nurses implemented a regular procedure of data analysis and internal benchmarking. The health care team was informed of any results, and suggested improvements. Every staff member involved in pain management participated in educational lessons, and a special pain nurse was trained in each ward. Results From 2014 to 2015, 367 patients were included. The mean maximal pain score 24 hours after surgery was 4.0 (±3.0) on an 11-point numeric rating scale, and patient satisfaction was 9.0 (±1.2). Over time, the maximum pain score decreased (mean 3.0, ±2.0), whereas patient satisfaction significantly increased (mean 9.8, ±0.4; pteamwork and flexibility in adapting processes seem to be highly important for successful pain management. PMID:28031727

  18. First hip arthroplasty register in Italy: 55,000 cases and 7 year follow-up

    OpenAIRE

    Stea, S.; Bordini, B.; Clerico, M; Petropulacos, K.; Toni, A.

    2007-01-01

    The Register for Orthopaedic Prosthetic Implantation (RIPO) has been prospectively collecting data on hip prostheses performed in all the orthopaedic units in the region Emilia-Romagna since January 2000. The register aims to determine the characteristics of patients, evaluate the effectiveness of prostheses, and allow internal audit. Adherence to the register is compulsory (93% capture). By 31 December 2006 the register contained data on 35,041 primary total hip arthroplasty (THA), 14,613 he...

  19. Conversion of fused hip to total hip arthroplasty with presurgical and postsurgical gait studies.

    Science.gov (United States)

    Bonin, Stephanie J; Eltoukhy, Moataz A; Hodge, W Andrew; Asfour, Shihab S

    2012-03-01

    This case study presents a subject with a fused hip converted to total hip arthroplasty. Kinematic gait analysis was conducted on 3 occasions, presurgery, 4 months postsurgery, and 2.5 years postsurgery. Presurgery data showed decreased cadence and shorter step length; sound limb possessed increased hip, knee range of motion (ROM), and increased knee flexion during stance; the affected limb had minimal hip motion and normal knee ROM with abnormal pattern. At 4 months postsurgery, the sound limb showed decreased step length, whereas the affected limb showed increased knee extension during stance and increased hip ROM. Data obtained at 2.5 years postsurgery indicated decreased cadence and speed and increased ROM in both limbs. The total hip arthroplasty had provided relief of chronic back and affected hip pain and improved mobility. Gait-specific training is recommended. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Cementless total hip arthroplasty with modified oblique femoral shortening osteotomy in Crowe type IV congenital hip dislocation.

    Science.gov (United States)

    Kiliçoğlu, Onder İ; Türker, Mehmet; Akgül, Turgut; Yazicioğlu, Onder

    2013-01-01

    Midterm results of cementless total hip arthroplasty in patients with Crowe type IV congenital dislocation of the hip were evaluated. A modified oblique subtrochanteric shortening osteotomy was used in all patients. A cylindrical femoral stem was used in all patients to stabilize the osteotomy. Mean follow-up was 82 months in 20 hips of 16 patients. Mean Merle D'Aubigné pain score increased from 2.52 to 5.65 points, function score improved from 4.0 to 5.3 points, and mobility score improved from 3.95 to 5.35. Mean greater trochanter height relative to the estimated hip center was 6.8 ± 2.0 cm preoperatively and -1 ± 0.2 cm postoperatively. Complications were dislocations in 3 patients, which were successfully managed without redislocation and fracture of greater trochanter in 3 patients, which healed uneventfully in 2 but with residual Trendelenburg gait in one. Total hip arthroplasty with modified oblique subtrochanteric shortening osteotomy is an effective technique for the treatment for Crowe type IV hip dislocation.

  1. Fast track in total hip and knee arthroplasty--experiences from Hvidovre University Hospital, Denmark

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte

    2006-01-01

    . 307 patients who sustained 329 hip and knee arthroplasties were included in the study with the main material constituted from 243 primary unilateral THA and TKA arthroplasties. ANORAK-HH includes pre-operative patient clinic, patient motivation, dedicated staff, unchanged criteria for discharge...... and a planned LOS of maximum 5 days. 22 patient characteristics and 11 satisfaction parameters were registered as well as readmissions within 3 months. 95% of patients had a LOS of maximum 5 days with a mean of 3.9 days. Median and mean values of satisfaction for the entire track were 10 and 9.4 out of 10...

  2. Post-anaesthesia care unit stay after total hip and knee arthroplasty under spinal anaesthesia

    DEFF Research Database (Denmark)

    Lunn, T H; Kristensen, B B; Gaarn-Larsen, L;

    2012-01-01

    patients operated with primary unilateral total hip or knee arthroplasty (THA or TKA) under spinal anaesthesia were included in this hypothesis-generating, prospective, observational cohort study during a 4-month period. Surgical technique, analgesia, and perioperative care were standardized. Well...

  3. Imaging of ceramic liner fractures in total hip arthroplasty: the value of CT

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Yoshimi; Mintz, Douglas N. [Hospital for Special Surgery, Department of Radiology and Imaging, New York, NY (United States); Renner, Lisa; Schmidt-Braekling, Tom; Boettner, Friedrich [Hospital for Special Surgery, Adult Reconstruction and Joint Replacement Division, New York, NY (United States)

    2015-08-15

    Fracture of a ceramic liner of a total hip arthroplasty is rare and is radiographically occult if not displaced. We report on two patients in whom ceramic liner fracture was radiographically occult but was diagnosed on subsequent CT scan through appropriate windowing. (orig.)

  4. Groningen orthopaedic exit strategy : Validation of a support program after total hip or knee arthroplasty

    NARCIS (Netherlands)

    van den Akker-Scheek, Inge; Zijlstra, Wiebren; Groothoff, Johan W.; van Horn, Jim R.; Bulstra, Sjoerd K.; Stevens, Martin

    2007-01-01

    Objective: Validation of the program theory of the Groningen orthopaedic exit strategy (GOES), a theory-driven program aiming to improve the rehabilitation of total hip and knee arthroplasty patients after shortened hospital stay. First part of the program theory is the action theory, hypothesising

  5. The use of postoperative suction drainage in total hip arthroplasty.

    Science.gov (United States)

    Acus, R W; Clark, J M; Gradisar, I A; Kovacik, M W

    1992-11-01

    Two hundred eight primary total hip arthroplasties were reviewed to evaluate the effect of closed suction drainage. This review included 45 hips in which closed drains were used and 163 hips in which drains were not used. These two groups were compared for possible differences in wound problems, temperature elevations, changes in Hgb/Hct, and the need for transfusions. There was no statistically significant difference in postoperative temperatures or decrease in Hgb. However, there were four superficial wound infections in the drained group and three superficial wound infections in the non-drained group (P < .025). There were no deep infections in either group. These findings suggest closed suction drainage provides no apparent advantage in uncomplicated primary total hip arthroplasty.

  6. Can Gait Deviation Index be used effectively for the evaluation of gait pathology in total hip arthroplasty An explorative randomized trial

    DEFF Research Database (Denmark)

    Jensen, Carsten; Rosenlund, Signe; Nielsen, Dennis Brandborg

    2014-01-01

    while walking at self-selected speed. Upon completion of the pre-operative assessment, the patients were randomly assigned to either resurfacing hip arthroplasty (RHA) or conventional total hip arthroplasty(THA). All patients were allowed early postoperative weight-bearing, and had rehabilitation...... changes in patients with hip OA following two types of THA. Methods: A total of 38 patients (11 females and 27 males, age 56 5.6, BMI 27.8 3.6) with unilateral end-stage primary hip osteoarthritis were evaluated pre-operatively, two- and six-months after total hip arthroplasty, using 3D gait analysis...... Deviation Index (GDI), used to evaluate treatment in children with cerebral palsy, has been proposed as such a measure. The experience with GDI in osteoarthritis (OA) patients following total hip arthroplasty (THA) is unknown. The aim of our study was to use the GDI to evaluate post-operative gait quality...

  7. Lunar phase does not influence perioperative complications in total hip arthroplasty.

    Science.gov (United States)

    Ficklscherer, Andreas; Angermann, Alexander; Weber, Patrick; Wegener, Bernd; Pietschmann, Matthias; Müller, Peter

    2012-02-29

    Lunar calendars, publishing recommendations for daily life, are gaining more and more attention in Germany, where 10.5% of the population believe in lunar effects on disease. A widespread and often heard belief is that a full moon has the most negative effects on surgical outcome. The present study evaluates the effects of lunar phase on perioperative complications in total hip arthroplasty. We performed a retrospective study with 305 patients being provided with a primary hip arthroplasty. To identify possible influences of the lunar phase on perioperative complications we investigated data such as operation length, blood loss and course of C-reactive protein that were collected during the patients' stay in the hospital and allocated them to moon illumination. There were no significant differences in all collected data concerning the lunar phase (p > 0.05). Although not statistically significant, there were fewer operations during the full moon phase. Therefore there is no evidence that lunar phase has an effect on perioperative complications in total hip arthroplasty. Fewer, though not significantly fewer, operations were performed during the full moon phase. Although this was not a prospective randomized trial, the statistical magnitude of the results does not support any recommendations for scheduling patients for total hip arthroplasty at any particular day of the lunar phase.

  8. 髋关节表面置换术治疗Crowe Ⅰ、Ⅱ型髋关节发育不良%Hip resurfacing arthroplasty for patients with Crowe Ⅰ and Crowe Ⅱ developmental dysplasia of the hip

    Institute of Scientific and Technical Information of China (English)

    王琦; 张先龙; 蒋垚; 陈云苏; 沈灏; 邵俊杰

    2014-01-01

    Objective To research the clinical results of hip resurfacing arthroplasty (HRA) for patients with Crowe type Ⅰ or Ⅱ developmental dysplasia of the hip(DDH).Methods From March 2005 to December 2006,a total of 80 Crowe type Ⅰ or Ⅱ dysplasia hip patients were randomly assigned for HRA or total hip replacement (THR).Three patients planed for HRA were converted to THR,three HRA patients and two THR patients were lost follow-up.This left a total of 34 patients (37 hips) who underwent HRA and 38 (39 hips) who underwent THR.Radiographic and clinical evaluations were taken 6 weeks,3months,1 year and then they were followed up annually.Results The mean follow-up period was 59.4 months (52 to 70) in the HRA group and 60.6 months (50 to 72) in the THR group.There was no failure of the prosthesis in either group.There was no difference in the mean post-operative Harris hip scores between the groups (P =0.073),while hip flexion was significandy better after HRA (P < 0.01).There was no difference in the mean abduction angle of the acetabular component between the two groups (P =O.982) and the mean size of the acetabular component in the HRA group was significantly larger than that in the THR group (49.5 mm vs 46.1 mm,P =0.001).Conclusions The clinical result after HRA was similar to that after THR,but flexion of the hip was better after HRA.More acetabular bone will be sacrificed in HRA in compensation for a bigger femoral head.%目的 研究Crowe Ⅰ型和Ⅱ型髋关节发育不良(DDH)患者行髋关节表面置换术(HRA)的临床结果.方法 前瞻性将2005年3月-2006年12月80例Crowe Ⅰ型和Ⅱ型DDH患者随机分入HRA组和全髋关节置换术(THR)组.HRA组中3例改行THR、3例失随访,THR组中2例失随访,故34例37髋接受HRA,38例39髋接受THR.在术后6周、3个月、1年,以后每年1次进行随访,接受放射学及临床评价.结果 HRA组和THR组分别平均随访59.4个月(52~ 70个月)及60.6个月(50~72个月),2

  9. Effect of proximal femoral osteoporosis on cementless hip arthroplasty: A short-term clinical analysis

    Institute of Scientific and Technical Information of China (English)

    LOU Xian-feng; LI Yu-hong; LIN Xiang-jin

    2007-01-01

    Objective: The aim of this retrospective investigation was to explore the influence of femoral osteoporosis on short-term curative effects of cementless hip arthroplasty and to evaluate the femoral metaphyseal bone mineral density (BMD) for femoral osteoporosis in order to guide prosthesis choice and rehabilitation. Methods: We performed 127 total arthroplasty operations between June 1999 to February 2003 and investigated 49 cementless hip replacements with the Metalcancellous cementless Lubeck Ⅱ system being used in all hips. There were twenty men and twenty-nine women whose mean age at the time of the operation was 60 years (range, 52~81 years). The patients were divided into osteoporosis or normal groups according to the femoral metaphyseal BMD measured preoperatively. The average duration of follow-up was 30 months (range, 8~52 months). We evaluated all of the patients from a clinical standpoint with use of a standard-terminology questionnaire with respect to the short-term curative effects and patients' satisfaction. Hip pain status and functional ability were important indicators of treatment efficacy. Results: Harris hip score and patients' satisfaction in femoral osteoporosis patients who underwent noncemented hip arthroplasty were lower (P=0.004, P=0.03) while the incidence of thigh pain was higher (P=0.03) than the patients with non-osteoporosis. Conclusion: The higher incidence of pain, as well as the decrease in function experienced by the patients in osteoporosis group, supports the case that cementless arthroplasty is not a better choice for those patients and that we had better select prosthesis based on the femoral metaphyseal BMD.

  10. Posterior hip approach yields better functional results vis-à-vis anterolateral approach in total hip arthroplasty for patients with severe hip dysplasia: A prospective randomized controlled clinical study.

    Science.gov (United States)

    Çatma, Faruk Mehmet; Öztürk, Alper; Ünlü, Serhan; Ersan, Önder; Altay, Murat

    2017-01-01

    We aimed to compare functional outcomes of two common hip approaches for patients with severe hip dysplasia in total hip replacement (THR) surgery. Seventy hips of 68 patients randomized into two groups with regard to hip approach as posterior (group I) and anterolateral (group II). All patients underwent THR surgery with femoral shortening osteotomy. The groups were compared for operation time, preoperative and 6 months after abductor muscle strengths (AMSs), gait disorders, union time of the osteotomied site and dislocation rates. There were two early dislocations in group I, and two early and one late dislocations in group II. No significant difference was observed regarding hip dislocations. Mean union time of the osteotomied site was 113.9 ± 51 days in group I while 111.1 ± 29.3 days in group II ( p = 0.774). Six months after surgery, group I had higher AMS than group II ( p dysplasia of hip is a challenging procedure, and posterior approach provides better functional outcomes regarding gait and AMSs.

  11. Malnutrition Increases With Obesity and Is a Stronger Independent Risk Factor for Postoperative Complications: A Propensity-Adjusted Analysis of Total Hip Arthroplasty Patients.

    Science.gov (United States)

    Fu, Michael C; D'Ambrosia, Christopher; McLawhorn, Alexander S; Schairer, William W; Padgett, Douglas E; Cross, Michael B

    2016-11-01

    Obesity is frequently associated with complications after total hip arthroplasty (THA) and is often concomitant with malnutrition. The purpose of this study was to investigate the independent morbidity risk of malnutrition relative to obesity. The National Surgical Quality Improvement Program from 2005 to 2013 was queried for elective primary THA cases. Malnutrition was defined as albumin malnutrition with 30-day outcomes. A total of 40,653 THA cases were identified, of which 20,210 (49.7%) had preoperative albumin measurements. Propensity score adjustment successfully reduced potential selection bias, with P > .05 for differences between those with and without albumin data. Malnutrition incidence increased from 2.8% in obese I to 5.7% in obese III patients. With multivariable propensity-adjusted logistic regression, malnutrition was a more robust predictor than any obesity class for any postoperative complication(s) (odds ratio [OR] 1.61, 95% confidence interval [CI] 1.25-2.08), major complications (OR 1.63, 95% CI 1.21-2.19), respiratory complications (OR 2.35, 95% CI 1.27-4.37), blood transfusions (OR 1.71, 95% CI 1.44-2.03), and extended length of stay (OR 1.35, 95% CI 1.14-1.59). Malnutrition incidence increased significantly from obese I to obese III patients and was a stronger and more consistent predictor than obesity of complications after THA. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Endotoxins in surgical instruments of hip arthroplasty.

    Science.gov (United States)

    Goveia, Vania Regina; Mendoza, Isabel Yovana Quispe; Guimarães, Gilberto Lima; Ercole, Flavia Falci; Couto, Bráulio Roberto Gonçalves Marinho; Leite, Edna Marilea Meireles; Stoianoff, Maria Aparecida Resende; Ferreira, José Antonio Guimarães

    2016-01-01

    To investigate endotoxins in sterilized surgical instruments used in hip arthroplasties. A descriptive exploratory study conducted in a public teaching hospital. Six types of surgical instruments were selected, namely: acetabulum rasp, femoral rasp, femoral head remover, chisel box, flexible bone reamer and femoral head test. The selection was based on the analysis of the difficulty in removing bone and blood residues during cleaning. The sample was made up of 60 surgical instruments, which were tested for endotoxins in three different stages. The EndosafeTM Gel-Clot LAL (Limulus Amebocyte Lysate method) was used. There was consistent gel formation with positive analysis in eight instruments, corresponding to 13.3%, being four femoral rasps and four bone reamers. Endotoxins in quantity ≥0.125 UE/mL were detected in 13.3% of the instruments tested. Investigar endotoxinas em instrumentais cirúrgicos esterilizados empregados em artroplastias do quadril. Estudo exploratório, descritivo, desenvolvido em um hospital público de ensino. Foram selecionados seis tipos de instrumentais, a saber: raspa acetabular, raspa femural, saca-cabeça de fêmur, formão box, fresa de fêmur e cabeça de prova de fêmur. A seleção foi feita a partir da análise da dificuldade para a remoção de resíduos de sangue e osso durante a limpeza. A amostra foi constituída por 60 instrumentais cirúrgicos, que foram testados para endotoxinas em três momentos distintos. Foi utilizado o método de gel-clot pelo Limulus Amebócito Lisado (LAL) Endosafe(tm). Houve formação de gel consistente com análise positiva em oito instrumentais, o que corresponde a 13,3%, sendo quatro raspas de fêmur e quatro fresas de fêmur. Foram detectadas endotoxinas em quantidade ≥0,125 UE/mL em 13,3% dos instrumentais testados.

  13. Tissue preserving total hip arthroplasty using superior capsulotomy.

    Science.gov (United States)

    Capuano, N; Del Buono, A; Maffulli, N

    2015-08-01

    The goals of a tissue-preserving minimally invasive approach to the hip are to allow early short-term recovery, achieve hip joint stability, minimize muscle strength loss from surgery, spare the peri-articular soft tissues, and allow unrestricted motion in the long term. Hip arthroplasty in patients with no pre-existing hardware, with a sufficient space between the acetabular rim and greater trochanter; management of subcapital femoral fractures in older patients. Protrusio acetabuli. Joint stiffness. This is the main concern when undertaking the superior capsulotomy. Stiffness may result from bone causes, including ankylosis, large osteophytes, bone bridges etc., extra-articular retraction of surrounding soft tissues with capsular contracture of both ligaments and muscles, or a combination of bony and soft tissues causes, resulting in limited adduction. Indeed, maximal adduction is necessary to increase the distance between the apex of the greater trochanter and the superior acetabular edge. In the approach described in the present article, the real limitation is the impossibility to introduce a straight stem through the trochanteric fossa without weakening the trochantericarea. If adduction is restricted, excessive lateralization of the femoral stem would result in postoperative pain and discomfort, especially as we advocate immediate full weight bearing. Even though patients fare better when the trochanteric area is intact, many types of stem such as the GTS (Biomet), or stem Microplasty (Biomet) or even stem Parva (Adler Ortho) may pressurize the internal bone of the trochanteric structures. Therefore, these stems may be implanted in maximal hip adduction. This is the case in coxa profunda or coxa vara, which require more invasive and destabilizing surgical approaches. Lateral position, 5-8 cm incision from the tip of the greater trochanter, identification and transaction of piriformis tendon. Anterior mobilization of the gluteus minimus and exposure of the

  14. Pseudoarthrosis of the ilium after periacetabular osteotomy that was treated by cemented total hip arthroplasty: a case report.

    Science.gov (United States)

    Kanaji, Arihiko; Nishiwaki, Toru; Oya, Akihito; Maehara, Kazuyuki; Maehara, Hideki; Oishi, Teruyo; Yamada, Harumoto; Suda, Yasunori; Nakamura, Masaya; Matsumoto, Morio

    2016-05-06

    Preserving the hip joint to delay arthroplasty for patients with acetabular dysplasia-associated early-stage osteoarthritis has become more common, and several surgical procedures have demonstrated pain relief and improved hip joint function. Periacetabular osteotomy, one of the joint-preserving surgical procedures of the hip, provides favorable outcomes, although there are no reports of total hip arthroplasty being used to treat pseudoarthrosis of the periacetabular osteotomy segment. Therefore, we report a case of pseudoarthrosis in the osteotomy segment after periacetabular osteotomy. The patient was treated using modified total hip arthroplasty and achieved a favorable short-term outcome. A 62-year-old Japanese woman was diagnosed with bilateral acetabular dysplasia at the age of 50 years, and underwent right and left periacetabular osteotomy at the ages of 52 and 55 years, respectively. When she was 61-years old, she experienced repeated episodes of left coxalgia during walking, with increasing pain at rest, and subsequently visited our department. Plain radiography and computed tomography of her left hip joint confirmed pseudoarthrosis of the periacetabular osteotomy segment. In addition, narrowing of her left hip joint space was observed, which indicated advanced osteoarthritis of the hip. Therefore, she underwent left total hip arthroplasty when she was 62-years old. During the surgery, fibrous fusion of the periacetabular osteotomy segment was confirmed via fluoroscopy, although no abnormal mobility was observed. Thus, the osteotomy segment was fixed with one absorbable screw and two bone pegs (which were prepared using allogeneic bone), and the acetabular cup was fixed using cement. Her postoperative course was generally favorable and bone fusion of the periacetabular osteotomy segment was confirmed at 3 years and 6 months after surgery. Her modified Harris hip score was 43 before the surgery and had improved to 90 at the final follow-up. Modified total

  15. Digital templating in total hip arthroplasty: Additional anteroposterior hip view increases the accuracy

    Science.gov (United States)

    Stigler, Sophia K; Müller, Franz J; Pfaud, Sebastian; Zellner, Michael; Füchtmeier, Bernd

    2017-01-01

    AIM To analyze planning total hip arthroplasty (THA) with an additional anteroposterior hip view may increases the accuracy of preoperative planning in THA. METHODS We conducted prospective digital planning in 100 consecutive patients: 50 of these procedures were planned using pelvic overview only (first group), and the other 50 procedures were planned using pelvic overview plus antero-posterior (a.p.) hip view (second group). The planning and the procedure of each patient were performed exclusively by the senior surgeon. Fifty procedures with retrospective analogues planning were used as the control group (group zero). After the procedure, the planning was compared with the eventually implanted components (cup and stem). For statistic analysis the χ2 test was used for nominal variables and the t test was used for a comparison of continuous variables. RESULTS Preoperative planning with an additional a.p. hip view (second group) significantly increased the exact component correlation when compared to pelvic overview only (first group) for both the acetabular cup and the femoral stem (76% cup and 66% stem vs 54% cup and 32% stem). When considering planning ± 1 size, the accuracy in the second group was 96% (48 of 50 patients) for the cup and 94% for the stem (47 of 50 patients). In the analogue control group (group zero), an exact correlation was observed in only 1/3 of the cases. CONCLUSION Digital THA planning performed by the operating surgeon and based on additional a.p. hip view significantly increases the correlation between preoperative planning and eventual implant sizes. PMID:28144576

  16. Boneloc bone-cement: experience in hip arthroplasty during a 3-year period.

    Science.gov (United States)

    Abdel-Kader, K F; Allcock, S; Walker, D I; Chaudhry, S B

    2001-10-01

    Polymethyl methacrylate (PMMA) bone-cement was introduced in the 1960s for fixation of total hip arthroplasty replacement components. Long-term results of cement fixation for hip and knee arthroplasty have been extremely good. Although the use of PMMA bone-cement has enabled long-term survival of joint arthroplasty implants, there has been concern about aseptic loosening. This concern led to the introduction of Boneloc bone-cement (Biomet, Warsaw, IN) in the early 1990s. It was hoped that with the improved physical and chemical characteristics of Boneloc, there would be less aseptic loosening in the long-term. A clinical trial was conducted to evaluate Boneloc bone-cement in cementing the femoral component of the Bimetric total hip arthroplasty prosthesis in 33 hips in 32 patients. On follow-up, 7 stems (24%) developed definite loosening, and 3 stems (10%) were possibly loose. Of the 7 definite loose stems, 5 (17%) were revised because of increasing pain or progressive loosening. Despite the biologic advantages of Boneloc, this study suggests that the chemicals substituted in Boneloc bone-cement led to an alteration in its mechanical properties. These properties proved to be inferior to conventional PMMA bone-cement. There is possible time-dependent deterioration of mechanical properties leading to early aseptic loosening. The conventional PMMA bone-cement has stood the test of time. Research and experimental studies should continue to improve the mechanical properties of Boneloc before further human trials.

  17. Inter-tester Reliability of the Hand-held dynamometer and the Leg Extensor Power Rig applied on Patients after Total Hip Arthroplasty

    DEFF Research Database (Denmark)

    Mikkelsen, Lone Ramer; Petersen, Annemette Krintel; Mikkelsen, Søren Søndergaard

    Background: Rehabilitation has an increasing focus on intensive resistance training early after joint replacement. This increases the requests for measuring changes in the muscle strength and muscle power over time. Hand-held dynamometer (HHD) is a device used to measure isometric muscle strength...... and Leg Extensor Power Rig (LEPR) is a tool for measuring muscle power. Purpose / Aim of Study: To test the inter-tester reliability of the HHD and the LEPR in Total Hip Arthroplasty (THA) patients. Materials and Methods: Two groups each consisting 20 subjects were included. Mean age was 68.4 years. All...... between the two testers (p=0.62) and the two tests (0.14); ICC=0.91 (95% CI: 0.79;0.96); LOA=±34Watt. Conclusions: The relative reliability was acceptable for both HHD and LEPR. The absolute reliability showed that a change in the muscle strength/power above 18 Newton or 34 Watt can be counted as a real...

  18. Reconstruction of neglected developmental dysplasia by total hip arthroplasty with subtrochanteric shortening osteotomy.

    Science.gov (United States)

    Atilla, Bülent

    2016-03-01

    Patients with neglected developmental dysplasia (DDH) face with early osteoarthritis of the hip, limb length inequality and marked disability while total hip reconstruction is the only available choice.DDH has severe morphologic consequences, with distorted bony anatomy and soft tissue contractures around the hip. It is critical to evaluate patients thoroughly before surgery.Anatomic reconstruction at the level of true acetabulum with uncemented implant is the mainstay of treatment. This requires a subtrochanteric shortening osteotomy, which can be realised using different osteotomy and fixation options.Although a demanding technique with a high rate of related complications, once anatomic reconstruction of the hip is achieved, patients have a remarkably good functional capacity and implant survival during long follow-up periods. Cite this article: Atilla B. Reconstruction of neglected developmental dysplasia by total hip arthroplasty with subtrochanteric shortening osteotomy. EFORT Open Rev 2016;1:65-71. DOI: 10.1302/2058-5241.1.000026.

  19. The efficacy of modified direct lateral versus posterior approach on gait function and hip muscle strength after primary total hip arthroplasty at 12months follow-up

    DEFF Research Database (Denmark)

    Rosenlund, Signe; Broeng, Leif; Overgaard, Søren;

    2016-01-01

    -seven patients with primary hip osteoarthritis were randomised to total hip arthroplasty with either posterior or lateral approach and evaluated pre-operatively, 3 and 12months post-operatively using 3-dimensional gait analyses as objective measures of gait function, including Gait Deviation Index, temporo...... in a randomised controlled trial. The aim was to compare the efficacy of total hip arthroplasty performed by lateral or posterior approach on gait function and hip muscle strength up to 12months post-operatively. We hypothesised that posterior approach would be superior to lateral approach. METHODS: Forty......-spatial parameters and range of motion. Isometric maximal hip muscle strength in abduction, flexion and extension was also tested. FINDINGS: Post-operatively, no between-group difference in gait function was observed. However, both hip abductor and flexor muscle strength improved more in the posterior approach group...

  20. Early Outcomes of Primary Total Hip Arthroplasty for Osteonecrosis of the Femoral Head in Patients with Human Immunodeficiency Virus in China

    Institute of Scientific and Technical Information of China (English)

    Chang-Song Zhao; Xin Li; Qiang Zhang; Sheng Sun; Ru-Gang Zhao; Juan Cai

    2015-01-01

    Background:Studies have reported that patients with human immunodeficiency virus (HIV) have a high incidence of osteonecrosis of the femoral head (ONFH).Total hip arthroplasty (THA) is an effective management of ONFH.However,little data exist regarding the use of THA for the HIV patients with ONFH in China.This study reviewed the outcomes of HIV-positive patients who underwent THA for ONFH,compared with HIV-negative individuals.Methods:The patients who underwent THA for ONFH from September 2012 to September 2014 in Beijing Ditan Hospital,Capital Medical University were retrospectively studied.Twenty-eight HIV-positive patients and 35 HIV-negative patients underwent 48 THAs and 45 THAs with cementless components,respectively.Medical records and follow-up data were reviewed.Harris Hip Score (HHS) was applied to evaluate the pain and function of the hips before and after THA.Complications such as wound healing,surgical site infection,deep venous thrombosis,pulmonary embolism,sepsis,mortality,and complications from the prosthesis were reviewed.The operation time,blood loss,and hospital stay were compared between the two groups.Results:The mean follow-up period was 19.5 ± 5.8 months (ranging from 6 to 30 months).The mean age of the HIV-positive patients with osteonecrosis at the time of surgery was 35 years old,which was significantly lower than that of the HIV-negative group (42 years old) (P < 0.05).The HIV-positive patients underwent surgery a mean of 2.5 years after their original symptoms,which was significantly shorter than the HIV-negatives' (mean 4 years) (P < 0.05).Among HIV-positive patients,the prevalence of being male and rate of bilateral procedures were significantly higher than those in the HIV-negative group (P < 0.05).The operation time in HIV-positive patients was significantly longer than that in HIV-negative patients (P < 0.05).There were no significant differences in blood loss or hospital stay between the two groups (P > 0.05).The HHSs

  1. Cementless Total Hip Arthroplasty With a High Hip Center for Hartofilakidis Type B Developmental Dysplasia of the Hip: Results of Midterm Follow-Up.

    Science.gov (United States)

    Chen, Min; Luo, Zheng-Liang; Wu, Ke-Rong; Zhang, Xiao-Qi; Ling, Xiao-Dong; Shang, Xi-Fu

    2016-05-01

    Acetabular reconstruction in adults with Hartofilakidis type B developmental dysplasia of the hip is a major technical challenge. The purpose of this retrospective study was to evaluate hip function and radiographic outcomes regarding high hip center at midterm follow-up. From January 1, 2007 to December 31, 2009, 37 patients who had Hartofilakidis type B developmental dysplasia of the hip underwent a primary total hip arthroplasty using a high hip center technique. Functional, radiographic, and survivorship outcomes were evaluated. Of the 37 patients, 31 patients (83.8%) were available for the mean follow-up of 6.1 years (range, 1.5-7.6 years). Thirty-one cementless cups were located at an average vertical distance of 38.1 ± 3.3 mm and at a mean horizontal distance of 35.5 ± 3.4 mm. The mean ratio of the height of the hip center was 2.4% (range, 2.0%-2.9%). The Harris Hip Scores were improved from 50.3 points (range, 38-63 points) preoperatively to 92.3 points (range, 85-100 points) at the final follow-up (P hip center technique in conjunction with a cementless acetabular component seems to be a valuable alternative to achieve satisfactory midterm outcomes for Hartofilakidis type B developmental dysplasia of the hip. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. [Superficial femoral vein thrombosis due to large psoas bursitis secondary to particle disease in total hip arthroplasty].

    Science.gov (United States)

    Lax-Pérez, R; Salinas-Gilabert, J E; Lajara-Marco, F; Lax-Pérez, A; Corraliza-Zamorano, A; García-Gálvez, A; Izquierdo-Plazas, L

    2012-01-01

    Male, 76 year-old patient with a history of total hip arthroplasty who presents with a mass in the iliac fossa with swelling of the thigh and hip pain upon flexion and extension. Complementary ultrasound and computed tomography scan studies show a giant lobulated cystic mass in the left iliac fossa, 7 cm in diameter, near the prosthesis. Cyst formation caused by polyethylene disease after total hip arthroplasty is infrequent. We present a case of large psoas bursitis secondary to the release of polyethylene particles which caused superficial femoral vein compression and thrombosis.

  3. The use of a constrained acetabular component to treat instability after total hip arthroplasty.

    Science.gov (United States)

    Shrader, M Wade; Parvizi, Javad; Lewallen, David G

    2003-11-01

    Recurrent dislocation after total hip arthroplasty is a disabling complication that can be difficult to treat and may not be amenable to nonoperative management. The purpose of the present study was to evaluate the clinical and radiographic outcome associated with the use of a constrained acetabular component as a salvage treatment for instability after hip arthroplasty. We retrospectively reviewed the clinical and radiographic outcome of 110 arthroplasties, in 109 patients, that had been performed with use of a single design of constrained acetabular component. In seventy-nine hips the constrained component was implanted for the treatment of recurrent instability, and in thirty-one hips it was implanted because of absent or grossly deficient soft-tissue attachments that were believed to be associated with a high risk for subsequent instability. The constrained acetabular device eliminated or prevented hip instability in all patients except two, who continued to have sensations of subluxation. The mean Harris hip score improved significantly, from 62.7 points preoperatively to 76.4 points at the time of the latest follow-up (p acetabular component loosening, and one for a periprosthetic fracture of the femur. A constrained acetabular component reliably restores and maintains hip stability in patients with recalcitrant recurrent instability and can dependably prevent dislocation in those who are at high risk because of absent or deficient soft tissues about the hip. However, because of the early appearance of radiolucent lines around some components and concerns about long-term fixation, the use of these devices should be reserved for situations in which other methods are inadequate or have already failed.

  4. Hip arthroplasty for treatment of advanced osteonecrosis: comprehensive review of implant options, outcomes and complications

    Directory of Open Access Journals (Sweden)

    Waewsawangwong W

    2016-06-01

    Full Text Available Warit Waewsawangwong, Pirapat Ruchiwit, James I Huddleston, Stuart B Goodman Department of Orthopedic Surgery, Stanford University, Stanford, CA, USA Abstract: Surgical treatment for late stage (post-collapse osteonecrosis of the femoral head is controversial. In these situations, the outcome of joint preservation procedures is poor. There are several arthroplasty options for late-stage disease. The clinical outcomes of hemiarthroplasty and hemiresurfacing are unpredictable because of progressive acetabular cartilage degeneration. Total hip resurfacing may be associated with further vascular insult to the femoral head and early failure of the implant. Total hip replacement with metal-on-conventional polyethylene bearing surfaces has been the gold standard, but implant survivorship is limited in young active patients due to wear and osteolysis. Newer alternative bearing surfaces may have improved wear characteristics, but their durability must be confirmed in longer-term studies. Keywords: hip arthroplasty, advanced osteonecrosis, implant options, outcomes, complications

  5. Minimal-invasive posterior approach for total hip arthroplasty versus standard lateral approach.

    Science.gov (United States)

    Schleicher, Iris; Haas, Holger; Adams, Tim S; Szalay, Gabor; Klein, Heiko; Kordelle, Jens

    2011-08-01

    In this prospective study we compared clinical and radiological results and rehabilitation progress of 64 patients who underwent total hip arthroplasty using the standard lateral approach with 64 patients operated with a minimal-invasive (MIS) posterior approach. The outcome of our study did not show any significant differences with regard to patient's safety such as complication rate and radiological assessment of the cup position. There was no difference in the duration of surgery, blood loss, hospital stay and postoperative leg length discrepancy. Rehabilitation milestones were achieved earlier by MIS patients and three and six months postoperatively, the Harris Hip Score of the MIS group was significantly higher.

  6. Hydroxyapatite coating does not improve uncemented stem survival after total hip arthroplasty!

    DEFF Research Database (Denmark)

    Hailer, Nils P; Lazarinis, Stergios; Mäkelä, Keijo T

    2015-01-01

    Background and purpose - It is still being debated whether HA coating of uncemented stems used in total hip arthroplasty (THA) improves implant survival. We therefore investigated different uncemented stem brands, with and without HA coating, regarding early and long-term survival. Patients...... and methods - We identified 152,410 THA procedures using uncemented stems that were performed between 1995 and 2011 and registered in the Nordic Arthroplasty Register Association (NARA) database. We excluded 19,446 procedures that used stem brands less than 500 times in each country, procedures performed due...

  7. Cost-utility of metal-on-metal hip resurfacing compared to conventional total hip replacement in young active patients with osteoarthritis

    NARCIS (Netherlands)

    Heintzbergen, S.; Kulin, N.A.; IJzerman, M.J.; Steuten, L.M.G.; Werle, J.; Khong, H.; Marshall, D.A.

    2013-01-01

    Background: Metal-on-metal hip resurfacing arthroplasty (MoM HRA) has emerged as an alternative to total hip arthroplasty (THA) for younger active patients with osteoarthritis (OA). Birmingham hip resurfacing is the most common MoM HRA in Alberta, and is therefore compared with conventional THA. Obj

  8. Efficacy and safety of rivaroxaban thromboprophylaxis after arthroplasty of the hip or knee: retrospective cohort study.

    Science.gov (United States)

    Loganathan, L; Hua, A; Patel, S; Gibbons, C; Vizcaychipi, M P

    2016-09-01

    Introduction Venous thromboembolism (VTE) is a potentially fatal complication of hip arthroplasty and knee arthroplasty. The National Institute for Health and Care Excellence recommend rivaroxaban for VTE prevention. Amid concerns over bleeding complications, the modified thromboprophylaxis policy of Chelsea and Westminster Hospital (CWH; London, UK) advises enoxaparin given after surgery in the inpatient setting followed by rivaroxaban upon hospital discharge. This retrospective study investigated the efficacy and safety of rivaroxaban in this novel, modified venous-prophylaxis regimen in a surgical orthopaedic cohort at CWH. Methods A total of 479 patients who received modified thromboprophylaxis treatment at CWH after hip arthroplasty or knee arthroplasty between April 2013 and October 2014 formed the study cohort. Seven outcomes based on efficacy and safety while undergoing treatment with rivaroxaban were investigated: symptomatic deep-vein thrombosis (DVT), pulmonary embolism (PE), death, stroke, myocardial infarction (MI), major bleeding episodes (MBEs) and non-major bleeding episodes (NMBEs). Median follow-up was 369 days. Fisher's exact and Mann-Whitney U-tests were adopted to identify associations with these outcomes. Results Prevalence of symptomatic PE, DVT, death, stroke and MI during treatment was zero. One (0.2%) MBE and nine (1.9%) NMBEs occurred. The MBE (a wound haematoma) required a return to theatre for aspiration. Off-treatment VTEs occurred in four (0.8%) patients after completion of a course of rivaroxaban, and were associated with known risk factors. Conclusions Rivaroxaban is an effective and safe anticoagulant for thromboprophylaxis after hip arthroplasty or knee arthroplasty if used in a modified regimen involving enoxaparin administered in the inpatient setting followed by rivaroxaban upon hospital discharge.

  9. [EFFECTIVENESS OF ANATOMIC FEMORAL COMPONENT PROSTHESIS FOR SEVERE DEVELOPMENTAL DYSPLASIA OF THE HIP IN TOTAL HIP ARTHROPLASTY].

    Science.gov (United States)

    An, Xiao; Dong, Jiyuan; Gong, Ke; Zhang, Qi; Li, Xiang; Song, Wei

    2015-04-01

    To evaluate the effectiveness of anatomic femoral component prosthesis for severe development dysplasia of the hip (DDH) in total hip arthroplasty (THA). Between September 2009 and September 2013, 48 patients (51 hips) with severe DDH underwent THA with cementless anatomic femoral component prosthesis. There were 5 males (5 hips) and 43 females (46 hips) with an average age of 51 years (range, 28-67 years). The left hip was involved in 25 cases, the right hip in 20 cases, and bilateral hips in 3 cases. There were 39 cases (44 hips) of Crowe type III and 9 cases (7 hips) of Crowe type IV. The visual analogue scale (VAS) score was 5.72 +/- 1.84, and Harris score was 41.66 +/- 4.87 at preoperation. All patients had leg discrepancy with a length difference of (4.31 +/- 0.84) cm. The duration of surgery was 59-110 minutes (mean, 78.6 minutes), and the hospitalization days were 6-20 days (mean, 12.3 days). All patients obtained primary healing of incision without wound related complications of swelling, effusion, and infection. Two patients were found to have intramuscular venous thrombosis. All patients were followed up 10-54 months (mean, 29 months). Limp was observed at the early stage after operation in 9 patients and disappeared after 1 year, the other patients had normal gait. The VAS score 1.46?0.47, Harris score 88.66 +/- 3.48, and the leg length difference (1.15 +/- 0.33) cm at last follow-up all showed significant differences when compared with the preoperative values (Phip joint function and limb discrepancy. Short-term effectiveness was satisfactory, but the long-term effectiveness should still be observed in future.

  10. An unusual case of persistent groin pain after total hip arthroplasty: a case report

    Directory of Open Access Journals (Sweden)

    Friederich Niklaus F

    2011-02-01

    Full Text Available Abstract Introduction Arthroplasty is a well-established routine elective surgical procedure in orthopaedics. To a great extent, diagnosis, treatment and post-operative rehabilitation in these patients is standardised. In a busy clinic, surgeons from time to time tend to focus their attention on common causes of joint pain, but it may lead them to overlook sinister but less common pathologies. Here we report a case of a patient with groin pain due to pre-operatively undetected pelvic metastases from a pyeloureteral carcinoma who underwent total hip arthroplasty. There are several case reports which deal with primary or secondary tumours which were either discovered at the time of replacement surgery or developed at the site of prosthesis years after total hip or knee replacement. To the best of our knowledge, this is the first case report in which a metastatic cancer was missed pre-operatively and intra-operatively both by the radiologist and by the orthopaedic surgeon and should be reported so that surgeons are reminded to be careful when dealing with seemingly routine cases. Case presentation A 79-year-old Caucasian woman presented to the arthroplasty clinic with groin pain. Initial radiographs showed subtle bilateral abnormalities in the pelvis. Neither the radiologist nor the orthopaedic surgeon recognized it. A diagnosis of osteoarthritis of the hip was established, and she underwent total hip arthroplasty. Despite initial improvement, the patient came back with worsening hip pain three months later. Further radiological examination revealed multiple metastatic lesions throughout the pelvis due to a pyeloureteral carcinoma. Conclusions This case report emphasizes the importance of meticulous, unbiased pre-operative assessment of patients and their radiographs, even in so-called routine clinical cases. Often subtle radiological changes are classed as normal, especially if they are bilateral. Further radiological imaging should be recommended

  11. Changes in bone mineral density of the acetabulum and proximal femur after total hip resurfacing arthroplasty.

    Science.gov (United States)

    Huang, Qiang; Shen, Bin; Yang, Jing; Zhou, Zong-ke; Kang, Peng-de; Pei, Fu-xing

    2013-12-01

    Our aim was to investigate the changes in bone mineral density (BMD) of acetabulum and proximal femur after total hip resurfacing arthroplasty. A comparative study was carried out on 51 hips in 48 patients. Group A consisted of 25 patients (26 hips) who had undergone total hip resurfacing and group B consisted of 23 patients (25 hips) who had had large-diameter metal-on-metal total hip arthroplasty (THA). BMDs around the acetabulum and proximal femur were measured using dual-energy x-ray absorptiometry (DEXA) at 2 weeks, 6 months, 1 year and annually thereafter during the 3 years after surgery. At final follow-up, the acetabular net mean BMD decreased by 11% in group A and 10% in group B with no differences between two groups (P = .35). For the femoral side, in Gruen zone 1, the mean BMD increased by 4% in group A, whereas it decreased by 11% in group B (P = .029). In Gruen zone 7, the mean BMD increased by 8% at the final follow-up in group A, whereas it decreased by 13% in group B (P = .02). In both groups the mean BMD increased by 3% in Gruen zones 3, 4, 5, and 6. Stress-related bone loss of the acetabulum was comparable for MOM THA and resurfacing devices, but proximal femoral bone density increased in the resurfacing group and decreased in the THA group.

  12. Range of Hip Joint Motion in Developmental Dysplasia of the Hip Patients Following Total Hip Arthroplasty With the Surgical Technique Using the Concept of Combined Anteversion: A Study of Crowe I and II Patients.

    Science.gov (United States)

    Zhang, Jingwei; Wei, Jianhe; Mao, Yuanqing; Li, Huiwu; Xie, Youzhuan; Zhu, Zhenan

    2015-12-01

    The combined anteversion surgical technique has been proposed and used in clinical practice. To more objectively evaluate the feasibility of this surgical technique using combined anteversion concept for DDH patients, we studied 34 DDH patients (40 hips) in this research. Every patient underwent pelvic CT scans before and after surgery and the HHSs were recorded. Optimal range of joint motion was measured using a three-dimensional reconstruction technique and a dynamic measurement technique. The results revealed that joint function met the requirements of daily life and the range of motion was not over-limited by impingement between the prosthesis and the skeleton. Moreover, the combined anteversion was found to be the most critical parameter in this study. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Arthroplasties of hips and knees ankylosis in an adolescent with acute lymphoblastic leukaemia.

    Directory of Open Access Journals (Sweden)

    Dipo Samuel OLABUMUYI

    2011-10-01

    Full Text Available Acute lymphoblastic leukaemia (ALL is the most common malignancy in children, representing one third of all paediatric malignancies. Patients are often at high risk for complications due aggressive chemotherapy regimes required for treatment. Musculoskeletal complications include septic arthritis, osteonecrosis, osteoporosis, avascular necrosis and bony ankylosis. We report the case of a 16-year-old boy with ALL who developed osteonecrosis of multiple bones on a background of septicaemia, resulting in bony ankylosis of both hips and knees. He was treated with bilateral conversion of ankylosed hips (one hip to total hip replacement, the second hip to Girdlestone arthroplasty and bilateral ankylosed knees to total knee replacements. He remained well in remission five years after the last surgery. Our case highlights he possible musculoskeletal complications of ALL. 

  14. Preoperative Hip Injections Increase the Rate of Periprosthetic Infection After Total Hip Arthroplasty.

    Science.gov (United States)

    Schairer, William W; Nwachukwu, Benedict U; Mayman, David J; Lyman, Stephen; Jerabek, Seth A

    2016-09-01

    Intraarticular injections are both diagnostic and therapeutic for patients with osteoarthritis. A potential risk of periprosthetic joint infection (PJI) after total hip arthroplasty (THA) may occur from direct inoculation and/or immune suppression by corticosteroids. Large population-level databases were used to evaluate hip injection on the 1-year rate of PJI in patients undergoing primary THA. State-level ambulatory surgery and inpatient databases for Florida and California (2005-2012) were used to identify primary THA patients with 1-year preoperative and postoperative windows to evaluate possible injections or PJI, respectively. Patients were grouped as no injection or as THA performed 6-12 months, 3-6 months, or 0-3 months after injection. Risk adjustment was performed with multivariable regression. A total of 173,958 patients were included; 5421 (3.1%) underwent THA after an injection: 1395 (1.1%) of patients after 6-12 months, 1863 patients after 3-6 months, and 2163 (1.2%) after 0-3 months. In the 0-3 month group, PJI was significantly increased at 3 months (1.58%, P = .015), 6 months (1.76%, P = .022), and 1 year (2.04%, P = .031) compared with the noninjection control group (1.04%, 1.21%, and 1.47%, respectively). There were no differences in the 3- to 6-month and 6- to 12-month injection groups. There is an increased risk of PJI when THA is performed within 3 months of hip injection. We recommend that patients and their surgeons consider delaying elective THA until 3 months after an injection to avoid this elevated risk of infection. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Current Concepts of Using Large Femoral Heads in Total Hip Arthroplasty

    OpenAIRE

    Cho, Myung-Rae; Choi, Won Kee; Kim, Jae Jung

    2016-01-01

    Instability and dislocation after total hip arthroplasty are the most common causes of revisions and major complications for failure of inserted prostheses, leading to a reduction in quality of life. Because the use of artificial femoral head sizes smaller than patient's own size is the important cause for dislocation, the use of large femoral head have increased. Femoral head sizes greater than 32 mm offer multiple advantages in physical function and activity levels of patients by improving ...

  16. Stop of loss of cognitive performance during rehabilitation after total hip arthroplasty-Prospective controlled study

    OpenAIRE

    Matthias H. Brem, MD, MHBA; Siegfried Lehrl, PhD; Anna K. Rein, MD; Sylvia Massute, BS; Stefan Schulz-Drost, MD; Kolja Gelse, MD; Phillip M. Schlechtweg, MD, MHBA; Friedrich F. Hennig, MD, PhD; Alexander Olk, MD; Harald J. Jacob, MD; Johannes Gusinde, MD

    2010-01-01

    Prolonged hospitalization is known to be associated with a loss of cognitive performance. Does playing video games (VGs) developed to improve cognitive properties delay this loss or even lead to an increase in cognitive performance? We performed a 10-day longitudinal study of patients who received total hip arthroplasty. We compared 16 patients (6 male) aged 66 ± 9 years (mean ± standard deviation) who played Dr. Kawashima's Brain Training: How Old Is Your Brain? (Nintendo; Redmond, Washingto...

  17. What determines length of stay after total hip and knee arthroplasty? A nationwide study in Denmark

    DEFF Research Database (Denmark)

    Husted, Henrik; Hansen, Hans Christian; Holm, Gitte

    2009-01-01

    : Nationwide implementation of fast-track THA and TKA would result in a significant decrease in the needed number of hospital beds with similar or better outcome for the patients. Implementation of updated logistical and clinical features is expected to increase rehabilitation and reduce LOS with similar...... or improved patient satisfaction. These results support the implementation of fast-track total hip- and knee arthroplasty....

  18. Knitted outer gloves in primary hip and knee arthroplasty.

    Science.gov (United States)

    Tanner, J; Wraighte, P; Howard, P

    2006-01-01

    A randomised trial was carried out to determine the rate of perforation to inner gloves when comparing latex with knitted gloves during hip and knee arthroplasty. Members of the surgical team were randomised to wear either two pairs of latex gloves (standard double gloving) or a knitted glove on top of a latex glove. In addition, participants completed a visual analogue assessment of their overall satisfaction with the gloves. A total of 406 inner gloves were tested for perforations over a four-month period: 23% of inner gloves were perforated when latex outer gloves were used and 6% of inner gloves were perforated when knitted outer gloves were used. In total, there were 64 perforations to the inner gloves; only one of these perforations was detected by the glove wearer. Wearing knitted outer gloves during hip and knee arthroplasty statistically significantly reduces the risk of perforation to inner latex gloves (p<0.0001).

  19. Do different types of bearings and noise from total hip arthroplasty influence hip-related pain, function, and quality of life postoperatively?

    DEFF Research Database (Denmark)

    Varnum, Claus; Pedersen, Alma B; Kjærsgaard-Andersen, Per;

    2016-01-01

    Background and purpose - Patient-reported outcome (PRO) is recognized as an important tool for evaluating the outcome and satisfaction after total hip arthroplasty (THA). We wanted to compare patient-reported outcome measure (PROM) scores from patients with ceramic-on-ceramic (CoC) THAs and those...

  20. Vibroacoustography for the assessment of total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Hermes A.S. Kamimura

    2013-04-01

    Full Text Available OBJECTIVES: This paper proposes imaging with 3-dimensional vibroacoustography for postoperatively assessing the uncovered cup area after total hip arthroplasty as a quantitative criterion to evaluate implant fixation. METHODS: A phantom with a bone-like structure covered by a tissue-mimicking material was used to simulate a total hip arthroplasty case. Vibroacoustography images of the uncovered cup region were generated using a two-element confocal ultrasound transducer and a hydrophone inside a water tank. Topological correction based on the geometry of the implant was performed to generate a 3-dimensional representation of the vibroacoustography image and to accurately evaluate the surface. The 3-dimensional area obtained by the vibroacoustography approach was compared to the area evaluated by a 3-dimensional motion capture system. RESULTS: The vibroacoustography technique provided high-resolution, high-contrast, and speckle-free images with less sensitivity to the beam incidence. Using a 3-dimensional-topology correction of the image, we accurately estimated the uncovered area of the implant with a relative error of 8.1% in comparison with the motion capture system measurements. CONCLUSION: Measurement of the cup coverage after total hip arthroplasty has not been well established; however, the covered surface area of the acetabular component is one of the most important prognostic factors. The preliminary results of this study show that vibroacoustography is a 3-dimensional approach that can be used to postoperatively evaluate total hip arthroplasty. The favorable results also provide an impetus for exploring vibroacoustography in other bone or implant surface imaging applications.

  1. Can pelvic tilting be ignored in total hip arthroplasty?

    Directory of Open Access Journals (Sweden)

    Won Yong Shon

    2014-01-01

    CONCLUSION: The sagittal position of pelvis is a key factor in impingement and dislocation after total hip arthroplasty. Pelvic tilting affects the position of acetabular component in the sagittal plane of the body as compared with its anatomic position in the pelvis. We suggest a preoperative lateral view of spine-pelvis, in upright and supine position for evaluation of a corrective adaptation of the acetabular cup accordingly with pelvic balance.

  2. Increasing risk of prosthetic joint infection after total hip arthroplasty

    DEFF Research Database (Denmark)

    Dale, Håvard; Fenstad, Anne M; Hallan, Geir;

    2012-01-01

    Background and purpose The risk of revision due to infection after primary total hip arthroplasty (THA) has been reported to be increasing in Norway. We investigated whether this increase is a common feature in the Nordic countries (Denmark, Finland, Norway, and Sweden). Materials and methods The...... explain this increase. We believe that there has been an actual increase in the incidence of prosthetic joint infections after THA....

  3. [Investigate progress of intraoperative periprosthetic fracture of total hip arthroplasty].

    Science.gov (United States)

    Cong, Yu; Zhao, Jian-ning

    2011-02-01

    One of the complications of total hip arthroplasty is intraoperative periprosthetic fracture. Periprosthetic fracture is divided into acetabular fracture and femoral fracture. Risk factors for intraoperative periprosthetic fracture include use of minimally invasive techniques, press-fit cementless stems, revision operations and osteoporosis. It has been recognized that treatment of intraoperative periprosthetic fractures should be based on the classification of the Vancouver system for intraoperative fractures.

  4. Total Hip Arthroplasty Complicated by a Gluteal Hematoma Resulting in Acute Foot Drop.

    Science.gov (United States)

    Khattar, Nicolas K; Parry, Phillip V; Agarwal, Nitin; George, Hope K; Kretz, Eric S; Larkin, Timothy M; Gruen, Gary S; Abla, Adnan A

    2016-01-01

    Total hip arthroplasty is a prevalent orthopedic intervention in the United States. Massive postoperative hematomas are a rare albeit serious complication of the procedure. Sequelae of these hematomas can include lower extremity paralysis from compression of the sciatic nerve. A 66-year-old woman taking aspirin and clopidogrel for coronary stents presented with a complete foot drop, paresthesias, and lower extremity pain 10 days after a total hip arthroplasty. The patient was initially seen by a neurology service at another hospital and thought to have lateral recess stenosis. At the authors' center, magnetic resonance imaging of the lumbar spine failed to show lateral recess stenosis. Urgent pelvic computed tomography showed a large hematoma and raised suspicion of sciatic nerve compression. Hip magnetic resonance imaging showed a right gluteal hematoma compressing the sciatic nerve. The patient was then taken to the operating room for the clot to be evacuated and was later referred for rehabilitation. Massive hematomas after total hip arthroplasty are an important consideration in the differential diagnosis of nontraumatic acute foot drop. Prompt diagnosis may correlate with improved neurological outcome and help reduce overall morbidity.

  5. Functional rehabilitation after total hip arthroplasty with uncemented prosthesis

    Directory of Open Access Journals (Sweden)

    Nicolae-Bogdan Negru-Aman

    2011-12-01

    Full Text Available Arthritis is a disease that acts irreversibly on joint surfaces with significant consequences especially in the third quarter of life. About 7% of our population is affected by arthritis localized at a certain level and stage of development, and this percentage is expected to reach a much higher value in future years. Aim: The aim of this study is to propose a rehabilitation program for functional recovery after total hip arthroplasty and a set of recommendations for post surgery period. Material and methods: There were included 13 subjects (10 female and 3 male aged between 51 and 78 years old, ready for total hip arthroplasty with uncemented prosthesis. The subjects were selected in Orthopaedics and Traumatology department of Military Clinical Emergency Hospital ”Dr. Victor Popescu” Timisoara. The evaluations regarding programs’ efficiency were made using 3 questionnaires (Oxford Hip Score, Harris Hip Score, Outcome Hip Score and goniometry. The subjects were tested initially before the surgery and 3 times after (at one month, at 3 months and at 6 months. Results: The results showed a remarcable increase for the scores of majority, in both questionnaire and goniometry values. Conclusions: functional rehabilitation exercises proved to be particularly important in regaining independence, control of the prosthetic leg, pain reduction and functional and social reintegration.

  6. Probability and heritability estimates on primary osteoarthritis of the hip leading to total hip arthroplasty

    DEFF Research Database (Denmark)

    Skousgaard, Søren Glud; Hjelmborg, Jacob; Skytthe, Axel;

    2015-01-01

    INTRODUCTION: Primary hip osteoarthritis, radiographic as well as symptomatic, is highly associated with increasing age in both genders. However, little is known about the mechanisms behind this, in particular if this increase is caused by genetic factors. This study examined the risk and heritab......INTRODUCTION: Primary hip osteoarthritis, radiographic as well as symptomatic, is highly associated with increasing age in both genders. However, little is known about the mechanisms behind this, in particular if this increase is caused by genetic factors. This study examined the risk...... and heritability of primary osteoarthritis of the hip leading to a total hip arthroplasty, and if this heritability increased with increasing age. METHODS: In a nationwide population-based follow-up study 118,788 twins from the Danish Twin Register and 90,007 individuals from the Danish Hip Arthroplasty Register...... not have had a total hip arthroplasty at the time of follow-up. RESULTS: There were 94,063 twins eligible for analyses, comprising 835 cases of 36 concordant and 763 discordant twin pairs. The probability increased particularly from 50 years of age. After sex and age adjustment a significant additive...

  7. Bone scintigraphic appearance of asymptomatic hydroxyapatite-coated hip arthroplasties.

    Science.gov (United States)

    Moilanen, T; Scott, G; Newell, M; Garvie, N; Freeman, M A

    1997-06-01

    To obtain information about the bone scintigraphic appearance of a hydroxyapatite (HA)-coated proximal femoral implant, this examination was performed on 24 patients with a clinically and radiologically successful femoral implant in hip arthroplasty. The prosthesis had a proximal HA coating for supplementary fixation. The patients' mean age was 50.3 years (range, 28-65 years) at operation. The interval from the operation to the scintigraphy ranged from 6 months to 5.5 years (mean, 2.2 years). Scintigraphy was performed using 99mTc-medronic acid. Quantitative counts were recorded in 4 zones: 3 along the length of the implant (trochanteric region with HA coating, midprosthesis, and distal tip) and 1 below the prosthesis. The results were expressed as ratios using the nonoperated femur as a control value. The results demonstrated that the mean activities in all 4 zones were increased relative to the untreated side. The highest activity was observed in the region around the prosthetic tip, with an elevation of 46% above the control value. This activity showed a significant decline over time. The counts recorded in the trochanteric region, where the implant was coated with HA, were 20% above the control value and similar to those seen in its adjacent noncoated midprosthetic region. In the trochanteric region, however, the activity did not show a decline over the follow-up period.

  8. [Minimally invasive total hip arthroplasty via direct anterior approach].

    Science.gov (United States)

    Rachbauer, Franz; Krismer, Martin

    2008-09-01

    Minimally invasive total hip arthroplasty via direct anterior approach aims at reducing soft-tissue damage, diminishing blood loss and postoperative pain, shortening stay in hospital, accelerating rehabilitation, and keeping scars small. The technique is suitable for primary and secondary osteoarthritis as well as fractures of the femoral neck. Complex distortions of the proximal femur should be exempted. Complex malalignment of the proximal femur. The femoral neck is exposed in the interval between tensor fasciae latae, glutei medius and minimus muscles laterally, and sartorius and rectus femoris muscles medially. After osteotomy of the neck and extraction of the head the acetabulum is reamed to prepare for cup prosthesis. Following peritrochanteric capsulotomy the externally rotated, adducted and elevated femor is broached. Cemented and cementless implants may be used. The patients are allowed to walk full weight bearing beginning on the 1st postoperative day. As soon as they are able to safely master the transfers and stairs, they are discharged. The method is a safe procedure that allows correct placement of acetabular and femoral components. It may be performed in a reasonable time, the blood loss is little. The procedure preserves the muscles and leads to small, cosmetically pleasing scars. Patients usually do not suffer from pronounced pain, rehabilitation is accelerated. They therefore agree in an short postoperative stay in hospital.

  9. Acetabular cup position and risk of dislocation in primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik;

    2016-01-01

    Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We perform...

  10. "Pros and cons" of total hip arthroplasty with metaphyseal Proxima endoprosthesis.

    Science.gov (United States)

    Wraźen, Waldemar; Golec, Edward B; Tomaszewski, Krzysztof A; Golec, Piotr; Jaworowski, Michał de Lubicz; Dudkiewicz, Zbigniew

    2015-01-01

    The authors present their own experience concerning total hip arthroplasty with the metaphyseal prosthesis Proxima. Proxima, a metaphyseal prosthesis, provides an innovative supplement to total hip arthroplasty. In this study, the authors present their own experience using Proxima in patients with hip osteoarthritis. This study was performed between 2008 to 2013 and comprised of 62 patients, of which 38 were male (61.3%) and 24 female (38.7%). All patients were operated on due to hip osteoarthritis using total hip arthroplasty with the metaphyseal prosthesis Proxima. The age of patients included into the study ranged from 23 years to 62 years with the mean age of 46 years. The authors paid close attention to the "pros and cons" of surgical techniques and assessed clinical and radiological results in both the short and long-term observation periods. The clinical evaluation was based on the Harris Hip Score and radiological assessment of fixation of the acetabular cup of the endoprosthesis was based on Pradhan's criteria. The endoprosthesis Proxima stem was positioned using the manufacturer's recommended method, evaluating the direction, scope and duration of the displacement in the marrow cavity of the proximal stump of the femur. According to the authors' analysis, the surgery gives good functional and radiological results both in the short- and long-term observation periods. The effectiveness depends on precise qualification for surgery, proper surgical techniques and specific anatomical conditions of the proximal femur stump. The most common reasons for primary and secondary dislocations of the metaphyseal endoprosthesis Proxima stem occur during the first three months post surgery. This is due to incorrect surgical techniques, which disregard the importance of specific anatomical conditions of the proximal femoral stump, which affects Proxima implantation, and cause deviations towards a varus or valgus orientation.

  11. Mountain sports and total hip arthroplasty: a case report and review of mountaineering with total hip arthroplasty.

    Science.gov (United States)

    Peters, Patrick

    2003-01-01

    Participation in certain sports after total hip arthroplasty (THA) is common. Some high-risk sports such as extreme endurance sports with risks of falls and fractures are often cautioned against, except when the sport was participated in preoperatively and an excellent physical condition is present postoperatively. In this article, current concepts pertaining to this issue in general and in relation to mountain sports are discussed after a description of the activities of a 69-year-old patient who received cementless bilateral THAs in 1987 and 1995 and who resumed, after each rehabilitation, his preoperative sports practice (eg, walking and high-altitude mountaineering [6000+ m]). The patient, who was experienced in alpine and high-altitude mountaineering, was able, after his first operation, to climb classic alpine peaks (4000+ m) as well as participate in difficult and strenuous climbs outside Europe (Kilimanjaro, Elbrus, and Rolwaling trekking). After the second operation and an intensive rehabilitation program, he was able to climb 2 mountains in the range of 6000+ m. With excellent physical training, a long preoperative practice of the sport, and an intensive and careful rehabilitation, patients with a THA are, under specific circumstances, able to perform mountaineering at a very high, even professional level without signs of prosthesis loosening or higher than normal wear of the bearing materials.

  12. Continuous Quadratus Lumborum Block for Postoperative Pain in Total Hip Arthroplasty: A Case Report.

    Science.gov (United States)

    Hockett, Margaret M; Hembrador, Sheena; Lee, Alex

    2016-09-15

    A 69-year-old man with a history of chronic pain and opioid use presented for total hip arthroplasty. In the interests of ensuring early mobilization and pain control, we chose a continuous quadratus lumborum block technique, a novel ultrasound-guided block that has not yet been described for total hip arthroplasty, hypothesizing that it would be motor-sparing. While the perineural catheter was infused, the patient required no IV opioids. He was able to ambulate on the first postoperative day, reporting pain scores between 0 and 3/10. The quadratus lumborum block is a promising technique that, in our patient, was motor-sparing and provided excellent pain control.

  13. Femoral head fractures: hemiarthroplasty or total hip arthroplasty?

    Science.gov (United States)

    Ullmark, Gösta

    2014-10-02

    Most femoral neck fractures are osteoporotic fractures in the elderly. The one-year mortality after neck fracture in this group is 24%.For hemiarthroplasty (HA) the bipolar heads have a risk reduction for reoperation due to acetabular erosion compared with monoblock heads. Surprisingly, the bipolar head had an increased reoperation risk for dislocation, infection and for periprosthetic fracture.Total hip arthroplasty (THA) after fracture has a four-fold raised risk for dislocation compared with THA after osteoarthritis. A larger head on the same neck (head to neck ratio) results in a theoretically larger range of movement and hence less risk for dislocation. The dual mobility bearing has, theoretically, the largest range of movement and good clinical results.Functional results are better for THA compared with HA. Arthroplasty for fracture has much better results compared with arthroplasty after a failed internal fixation; the risk for reoperation is more than doubled for the latter.A Swedish hip arthroplasty register study found a 20-fold higher risk for periprosthetic fracture when comparing uncemented HA with matt cemented HA. Also a polished cemented stem had 13½-fold higher risks compared with a matt.The mortality during the first day after surgery is higher for cemented compared with uncemented arthroplasties, but lower after one week, one month and one year. Analysing the time points together resulted in no difference.A matt cemented THA with a maximum head size, maybe dual mobility, has the best results, and is also for the low-demanding elderly.

  14. Transfusion-related mortality after primary hip arthroplasty - an analysis of mechanisms and confounders

    DEFF Research Database (Denmark)

    Jans, O; Kehlet, H; Johansson, P I

    2012-01-01

    Background and Objectives Bleeding and postoperative anaemia after total hip arthroplasty (THA) may trigger transfusion of red blood cells (RBC). However, large observational studies have reported associations between RBC transfusion and increased postoperative morbidity and mortality. As major...... bleeding or severe postoperative anaemia is intrinsically linked with RBC transfusion, direct causality between transfusion and adverse outcomes remains unclear. This study aimed to identify possible relations between RBC transfusion, severe bleeding or anaemia and mortality in all patients who died...

  15. Effect of high-dose preoperative methylprednisolone on recovery after total hip arthroplasty

    DEFF Research Database (Denmark)

    Lunn, T H; Andersen, Lasse Østergaard; Kristensen, B B

    2013-01-01

    BACKGROUND: /st>High-dose glucocorticoid may reduce postsurgical pain and improve recovery. We hypothesized that 125 mg methylprednisolone (MP) would reduce time to meet functional discharge criteria after total hip arthroplasty (THA). METHODS: /st>Forty-eight patients undergoing unilateral THA...... well-defined functional discharge criteria. Secondary outcomes were handgrip strength and endurance, pain, nausea, vomiting, fatigue, sleep quality, and rescue analgesic-, antiemetic-, and hypnotic medicine requirements. The inflammatory response measured by C-reactive protein (CRP) and actual length...

  16. Management strategies for infected total hip arthroplasty. A critical appreciation of problems and techniques.

    Science.gov (United States)

    Karachalios, Theofilos; Koutalos, Antonios; Komnos, George

    2014-10-02

    Infection is a devastating complication of total hip arthroplasty (THA). Risk factors have been recognised and prevention is possible. The nature of the disease is heterogeneous and for satisfactory management one has to weigh factors related to pathogen, host, local soft tissue, bone stock, surgeon experience and financial resources. Available data in the current literature is of poor quality and there is a lack of data comparing different techniques. Referral of patients to dedicated departments with the appropriate facilities may be more appropriate.

  17. Calcaneal stress fracture: an adverse event following total hip and total knee arthroplasty: a report of five cases.

    Science.gov (United States)

    Miki, Takaaki; Miki, Takahito; Nishiyama, Akihiro

    2014-01-15

    Stress fractures have been reported to occur in the pubis, femoral neck, proximal part of the tibia, and fabella during the postoperative period following total knee or total hip arthroplasty. However, to our knowledge, calcaneal stress fractures after total hip or total knee arthroplasty have not been reported in the English-language literature. Most orthopaedic surgeons are not familiar with calcaneal stress fractures that may occur in elderly patients after a total knee or total hip arthroplasty. We retrospectively reviewed the clinical features, imaging findings, and bone mineral content of the proximal part of the femur and the distal end of the radius in five patients who had a calcaneal stress fracture after a total knee or total hip arthroplasty. All patients were women with a mean age of 76.8 years. All fractures occurred in the calcaneus on the same side as the arthroplasty. The fracture appeared at a mean of 10.2 weeks postoperatively. All patients reported heel pain on walking. Swelling and local heat were found in four and three patients, respectively. Pain was elicited by squeezing the calcaneus in all patients. Early radiographs had normal findings in two patients, and an irregular sclerotic line appeared later in the radiographs of all patients. All fractures were treated conservatively. Four fractures healed uneventfully, but one fracture displaced. All patients had osteoporosis. Calcaneal stress fractures during the postoperative period following total knee or total hip arthroplasty may not be as rare as previously thought. Because clinical symptoms of the fracture appear insidiously and radiographic findings are absent or subtle in the early stage, a high index of suspicion is needed for orthopaedic surgeons to make the correct diagnosis. Magnetic resonance imaging or repeated radiographs may be necessary to make the correct diagnosis when no abnormality is apparent on the initial radiograph.

  18. Hip resurfacing arthroplasty: mid-term results in 486 cases and current indication in our institution.

    Science.gov (United States)

    Ribas, Manuel; Cardenas, Carlomagno; Astarita, Emanuele; Moya, Esther; Bellotti, Vittorio

    2014-10-02

    In the previous decade, metal-on-metal hip resurfacing has been considered an attractive option and theoretically advantageous over conventional total hip arthroplasty, especially in young active patients. Different authors have reported favourable mid-term clinical and functional results with acceptable survival rates. Proper indication and planning, as accurate technical execution have been advocated to be crucial elements for success.Concerns regarding serum metal ion levels and possible clinical implications have led in the last years to a decline in the use of metal-on-metal hip resurfacing and metal-on-metal bearings in general.The aim of this study is to present the results of our first 486 cases of hybrid hip resurfacing arthroplasties with a second generation cementing technique, and to describe our current restricted indication of this type of prosthesis, in the light of recent findings in the literature about the possible complications related to metallosis or improper patient selection. Global survivorship of our series was 97.9% at a mean follow-up of 7.2 years.In the second season of our experience the indication is restrictive. The candidate for a resurfacing hip replacement is a young and active male patient, with good bone quality, that has been made aware of the risks and benefits of this type of prosthesis.

  19. A modified two-incision technique for primary total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Bal B

    2008-01-01

    Full Text Available Background: Minimally invasive surgery can be technically demanding but minimizes surgical trauma, pain and recovery. Two-incision minimally invasive surgery allows only intermittent visualization and may require fluoroscopy for implant positioning. We describe a modified technique for primary total hip arthroplasty, using two small incisions with a stepwise approach and adequate visualization to reliably and reproducibly perform the surgery without fluoroscopy. Materials and Methods: One hundred and two patients with an average age of 60 years underwent modified two-incision minimally invasive technique for primary THA without fluoroscopy. The M/L taper femoral stem (Zimmer, Warsaw, IN and Trilogy (Zimmer hemispherical titanium shell, with a highly cross-linked polyethylene liner, was used. Operative time, blood loss, postoperative hospital stay, radiographic outcomes and complications were recorded. Results: The mean operating time was 77 min. The mean blood loss was 335 cc. The mean hospital stay was 2.4 days. Mean cup abduction angle was 43.8°. Mean leg length discrepancy was 1.7 mm. Thirteen patients had lateral thigh numbness and two patients had wound complications that resolved without any treatment. Conclusion: A modified two-incision technique without fluoroscopy for primary total hip arthroplasty has the advantage of preserving muscles and tendons, shorter recovery and return to function with minimal complications. Provided that the surgeon has received appropriate training, primary total hip arthroplasty can be performed safely with the modified two-incision technique.

  20. 老年患者人工髋关节置换术的手术配合及护理%Operation cooperation and nursing of elderly patients with hip arthroplasty surgery

    Institute of Scientific and Technical Information of China (English)

    牛铁铮; 韩玉顺; 孙先秀

    2015-01-01

    Objective:To explore the operation cooperation and nursing measures of elderly patients with hip arthroplasty surgery. Methods:The operation cooperation and nursing cooperation of 35 cases of elderly patients with hip arthroplasty surgery were analyzed.The cooperation and nursing key points were summarized.Results:35 cases of patients went through the surgery successfully and there was no postoperative infection.Conclusion:Sufficient preoperative preparation,skilled intraoperative coordination,correct postoperative transshipment,strict aseptic technique and patient psychological nursing in whole-course were the keys to the success of surgery.%目的:探讨老年患者行人工全髋关节置换术的手术配合及护理措施。方法:分析35例老人全髋置换术的手术配合及护理配合,总结配合及护理要点。结果:35例患者均顺利完成手术,未发生术后感染。结论:充分的术前准备、熟练的术中配合、正确的术后转运、严格的无菌技术操作及全程耐心的心理护理是手术成功的关键。

  1. Contralateral Total Hip Arthroplasty After Hindquarter Amputation

    Directory of Open Access Journals (Sweden)

    Scott M. M. Sommerville

    2006-01-01

    Full Text Available We describe the management and outcome of a 62-year old lady who developed severe osteoarthritis of the hip, nine years after a hindquarter amputation for radiation-induced sarcoma of the contralateral pelvis. The difficulties of stabilising the pelvis intraoperatively and the problems of postoperative rehabilitation are outlined. The operation successfully relieved her pain and restored limited mobility.

  2. Contralateral Total Hip Arthroplasty After Hindquarter Amputation

    Science.gov (United States)

    Sommerville, Scott M. M.; Patton, James T.; Luscombe, Jonathan C.; Grimer, Robert J.

    2006-01-01

    We describe the management and outcome of a 62-year old lady who developed severe osteoarthritis of the hip, nine years after a hindquarter amputation for radiation-induced sarcoma of the contralateral pelvis. The difficulties of stabilising the pelvis intraoperatively and the problems of postoperative rehabilitation are outlined. The operation successfully relieved her pain and restored limited mobility. PMID:17496994

  3. [Favourable long-term results from cemented total hip arthroplasty combined with acetabular bone impaction grafting in patients under the age of 50

    NARCIS (Netherlands)

    Busch, V.J.; Gardeniers, J.W.M.; Slooff, T.J.J.H.; Veth, R.P.H.; Schreurs, B.W.

    2007-01-01

    OBJECTIVE: Determination of long-term results of hip replacements in patients who, at the time of operation, were under the age of 50. Procedures whereby an existing acetabulum defect was filled with bone chips that were impacted into a strong layer, after which a cemented total hip prosthesis was i

  4. Total Hip Arthroplasty for Implant Rupture after Surgery for Atypical Subtrochanteric Femoral Fracture

    Science.gov (United States)

    Ozaki, Yu; Ochi, Hironori; Watari, Taiji; Matsumoto, Mikio; Kaneko, Kazuo

    2016-01-01

    Treatment methods for delayed union and nonunion of atypical femoral fracture are still controversial. Moreover, no treatment method has been established for implant rupture caused by delayed union and nonunion. We encountered a 74-year-old female in whom nonunion-induced implant rupture occurred after treatment of atypical subtrochanteric femoral fracture with internal fixation using a long femoral nail. It was unlikely that sufficient fixation could be obtained by repeating osteosynthesis alone. Moreover, the patient was elderly and early weight-bearing activity was essential for early recovery of ADL. Based on these reasons, we selected one-stage surgery with total hip arthroplasty and osteosynthesis with inverted condylar locking plate as salvage procedures. Bone union was achieved at 6 months after surgery. This case illustrated that osteosynthesis-combined one-staged total hip arthroplasty could be considered as one of the options for nonunion-induced implant rupture of atypical femoral subtrochanteric fracture. PMID:27818818

  5. Total Hip Arthroplasty for Implant Rupture after Surgery for Atypical Subtrochanteric Femoral Fracture

    Directory of Open Access Journals (Sweden)

    Yu Ozaki

    2016-01-01

    Full Text Available Treatment methods for delayed union and nonunion of atypical femoral fracture are still controversial. Moreover, no treatment method has been established for implant rupture caused by delayed union and nonunion. We encountered a 74-year-old female in whom nonunion-induced implant rupture occurred after treatment of atypical subtrochanteric femoral fracture with internal fixation using a long femoral nail. It was unlikely that sufficient fixation could be obtained by repeating osteosynthesis alone. Moreover, the patient was elderly and early weight-bearing activity was essential for early recovery of ADL. Based on these reasons, we selected one-stage surgery with total hip arthroplasty and osteosynthesis with inverted condylar locking plate as salvage procedures. Bone union was achieved at 6 months after surgery. This case illustrated that osteosynthesis-combined one-staged total hip arthroplasty could be considered as one of the options for nonunion-induced implant rupture of atypical femoral subtrochanteric fracture.

  6. Early Clinical and Radiographic Results of Minimally Invasive Anterior Approach Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Tamara Alexandrov

    2014-01-01

    consecutive patients with 43 total hip arthroplasties performed through an anterior muscle sparing minimally invasive approach. We found the early complication rates and radiographic outcomes comparable to those reported from arthroplasties performed via traditional approaches. Complications included dislocation (2%, femur fracture (2%, greater trochanteric fracture (12%, postoperative periprosthetic intertrochanteric fracture (2%, femoral nerve palsy (5%, hematoma (2%, and postoperative iliopsoas avulsion (2%. Radiographic analysis revealed average cup anteversion of 19.6°±6.6, average cup abduction angle of 48.4°±7, stem varus of 0.9°±2, and a mean leg length discrepancy of 0.7 mm. The anterior approach to the hip is an attractive alternative to the more traditional approaches. Acceptable component placement with comparable complication rates is possible using a muscle sparing technique which may lead to faster overall recovery.

  7. Association between fixation technique and revision risk in total hip arthroplasty patients younger than 55 years of age. Results from the Nordic Arthroplasty Register Association

    DEFF Research Database (Denmark)

    Pedersen, A B; Mehnert, F; Havelin, L I;

    2014-01-01

    to Norway, Sweden and Finland. Conclusions: Uncemented implants perform better in relation to long-term risk of aseptic loosening, whereas both uncemented and hybrid rather than cemented implants in patients younger than 55 years had more short-term revisions because problems due to dislocation......, periprosthetic fracture and infection has not yet been completely solved. The vast majority of cup-stem combinations were used in very few operations. (C) 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved....

  8. Imaging evaluation of complications of hip arthroplasty: review of current concepts and imaging findings.

    Science.gov (United States)

    Awan, Omer; Chen, Lina; Resnik, Charles S

    2013-11-01

    Total hip arthroplasty has evolved along with improvements in component materials and design. The radiologist must accurately diagnose associated complications with imaging methods and stay informed about newer complications associated with innovations in surgical technique, prosthetic design, and novel materials. This pictorial essay presents clinical and imaging correlation of modern hip arthroplasty complications, with an emphasis on the most common complications of instability, aseptic loosening, and infection as well as those complications associated with contemporary metal-on-metal arthroplasty.

  9. Predictors of pain and physical function at 3 and 12 months after total hip arthroplasty

    DEFF Research Database (Denmark)

    Plews, Sarah; Løvlund Nielsen, Randi; Overgaard, Søren;

    Background: Few studies have combined preoperative patient-reported and objective outcome measures to predict outcomes after total hip arthroplasty (THA). Purpose / Aim of Study: to identify predictors of outcome 3 and 12 months after THA Materials and Methods: A cohort of 107 consecutive patients...... with primary hip osteoarthritis responded to Hip dysfunction and Osteoarthritis Outcome Score (HOOS) questionnaires prior to and 3 and 12 months after THA. Preoperative pain intensity; joint space width (JSW), age, gender, and body mass index (BMI) were used to predict changes in pain and physical function....... Conclusions: Preoperative pain predicted changes in pain and physical function up to one year after THA. Such knowledge should be taken into consideration, when assessing OA patients prior to surgery. This study provides useful insight for clinicians, regarding the overall improvement patients can expect...

  10. Current expert views on metal-on-metal hip resurfacing arthroplasty. Consensus of the 6th advanced Hip resurfacing course, Ghent, Belgium, May 2014.

    Science.gov (United States)

    Van Der Straeten, Catherine; De Smet, Koen A

    2016-01-01

    This paper reports the consensus of an international faculty of expert metal-on-metal (MoM) hip resurfacing surgeons, with a combined experience of over 40,000 cases, on the current status of hip resurfacing arthroplasty. Indications, design and metallurgy issues, release of metal ions and adverse soft tissue reactions to particles, management of problematic cases and revisions, as well as required experience and training are covered. The overall consensus is that MoM hip resurfacing should not be banned and should be viewed separately from MoM total hip arthroplasty (THA) with a large diameter head because of the different design and wear behaviour related to the taper/trunnion connection. The use of hip resurfacing has decreased worldwide but specialist centres continue to advocate hip resurfacing in young and active male patients. Regarding age the general recommendation is to avoid hip resurfacing in men older than 65 and in women older than 55, depending on the patient activity and bone quality. Female gender is considered a relative contraindication. Most surgeons would not implant a MoM hip in women who would still like a child. Regardless of gender, there is a consensus not to perform hip resurfacing in case of a femoral head size smaller than 46 mm and in patients with renal insufficiency or with a known metal allergy. Regarding follow-up of hip resurfacing and detection of adverse local tissue reactions, metal ion measurements, MRI and ultrasound are advocated depending on the local expertise. The consensus is that hip resurfacing should be limited to high volume hip surgeons, who are experienced in hip resurfacing or trained to perform hip resurfacing in a specialist centre.

  11. The use of the Gait Deviation Index for the evaluation of participants following total hip arthroplasty

    DEFF Research Database (Denmark)

    Jensen, Carsten; Rosenlund, Signe; Nielsen, Dennis B;

    2015-01-01

    trial was used to determine changes in gait quality in participants walking at self-selected speed. Upon completion of the first assessment, the participants were randomly assigned to either resurfacing hip arthroplasty or conventional hip arthroplasty. The outcome was changes in overall gait 'quality......, there was no additional effect of resurfacing hip arthroplasty on GDI scores compared with conventional hip arthroplasty. Participants with the most pathological preoperative gait pattern improved the most. The GDI increased, which indicates an overall improvement in gait pathology after surgery. TRIAL REGISTRATION: NCT......INTRODUCTION: In this paper, the Gait Deviation Index (GDI) was used as a convenient method to evaluate pre-to-postoperative gait pattern changes after total hip arthroplasty and identify factors which might be predictive of outcome. DESIGN: Three-dimensional gait data from a randomized clinical...

  12. [Femoral superficial vein thrombosis due to a large iliopsoas bursitis secondary to polyethylene wear debris in total hip arthroplasty].

    Science.gov (United States)

    Lax Pérez, R; Salinas Gilabert, J E; Lajara Marco, F; Lax Pérez, A; Ferrero Manzanal, F; García-Gálvez, A; Izquierdo Plazas, L

    2012-01-01

    A 76 year old male patient with a history of implantation of a total hip arthroplasty Perfecta (Orthomet(®)), who presented with an iliac fossa mass, increased diameter of the thigh, and pain during hip flexion and extension. CT and ultrasound show the presence of a giant cystic mass in left iliac fossa about 7 cm in diameter next to the prosthesis. A pseudo-tumour secondary to wear debris after placement of a total arthroplasty is rare. We present a case of a large iliopsoas bursitis caused by polyethylene particles, which caused compression and thrombosis of the superficial femoral vein. Copyright © 2011 SECOT. Published by Elsevier Espana. All rights reserved.

  13. Second generation cephalosporin antibiotic prophylaxis and Clostridium difficile infection in hip and knee arthroplasty.

    Science.gov (United States)

    Al-Tawil, K; Babu, A; Loeffler, M; Williams, T

    2017-05-01

    Introduction The use of broad spectrum cephalosporin antibiotics has been discouraged by the Department of Health in England because of the link to increased Clostridium difficile infection rates. The aim of this study was to evaluate whether a local protocol that included the use of second generation cephalosporin (cefuroxime) antibiotics as a prophylactic agent was associated with increased risk of C difficile in elective hip and knee arthroplasty patients. Methods A retrospective intention-to-treat study was conducted. An infection control database of all cases of C difficile infection both in hospital and in the community was reviewed and cross-referenced against surgical records. A positive correlation was identified when a C difficile positive sample was documented within eight weeks of arthroplasty surgery. Results Only 1 case (0.02%) of C difficile positive diarrhoea was identified that correlated to the 8-week postoperative period following 4,488 arthroplasty procedures. Conclusions The use of cephalosporin antibiotic prophylaxis in the elective hip and knee arthroplasty setting does not appear to be associated with increased C difficile infection rates, achieving surgical site infection rates that are comparable with the national average.

  14. Predictors and complications of blood transfusion in total hip and knee arthroplasty.

    Science.gov (United States)

    Frisch, Nicholas B; Wessell, Nolan M; Charters, Michael A; Yu, Stephen; Jeffries, James J; Silverton, Craig D

    2014-09-01

    Perioperative patient optimization can minimize the need for blood transfusions in patients undergoing total hip arthroplasty (THA) and total knee arthroplasty (TKA). The purpose of this study was to determine predictors and complications of transfusions. This retrospective review analyzed 1795 patients who underwent primary THA and TKA at our institution between January 2011 and December 2012. Of the 1573 patients ultimately included the rates of transfusion were 9.27% in TKA and 26.6% in THA. Significant predictors for transfusion include: preoperative hemoglobin, age, female gender, body mass index, creatinine, TKA, operating room time, operative blood loss, and intra-operative fluids. The DVT rate was comparable, but deep surgical site infection rate among transfused patients was 2.4% compared to 0.5% in non-transfused patients (P = 0.0065).

  15. Fast track in total hip and knee arthroplasty--experiences from Hvidovre University Hospital, Denmark

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte

    2006-01-01

    This study investigated whether unselected patients operated on with total hip arthroplasty (THA) or total knee arthroplasty (TKA) could accomplish a self-developed accelerated track, ANORAK-HH, with a planned length of stay (LOS) of maximum 5 days and patient satisfaction at all parts of the track...... and a planned LOS of maximum 5 days. 22 patient characteristics and 11 satisfaction parameters were registered as well as readmissions within 3 months. 95% of patients had a LOS of maximum 5 days with a mean of 3.9 days. Median and mean values of satisfaction for the entire track were 10 and 9.4 out of 10......, respectively. Participation in patient clinic did not influence LOS or satisfaction. Operations at the beginning of the week and lack of blood transfusion were associated with shorter LOS. Finally, ANORAK-HH could be effectively accomplished in unselected THA and TKA patients without having an adverse effect...

  16. The John Charnley Award: Metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial.

    Science.gov (United States)

    Garbuz, Donald S; Tanzer, Michael; Greidanus, Nelson V; Masri, Bassam A; Duncan, Clive P

    2010-02-01

    Resurfacing arthroplasty has become an attractive option for young patients who want to maintain a high activity level. One recent study reported modestly increased activity levels for patients with resurfacing compared to standard total hip arthroplasty (THA). We conducted a prospective randomized clinical trial to compare clinical outcomes of resurfacing versus large-head metal-on-metal total hip arthroplasty. We randomized 107 patients deemed eligible for resurfacing arthroplasty to have either resurfacing or standard THA. Patients were assessed for quality-of-life outcomes using the PAT-5D index, WOMAC, SF-36, and UCLA activity score. The minimum followup was 0.8 years (mean, 1.1 years; range, 0.8-2.2 years). Of the 73 patients followed at least one year, both groups reported improvement in quality of life on all outcome measures. There was no difference in quality of life between the two arms in the study. Serum levels of cobalt and chromium were measured in a subset of 30 patients. In both groups cobalt and chromium was elevated compared to baseline. Patients receiving a large-head metal-on-metal total hip had elevated ion levels compared to the resurfacing arm of the study. At 1 year, the median serum cobalt increased 46-fold from baseline in patients in the large-head total hip group, while the median serum chromium increased 10-fold. At 1 year, serum cobalt was 10-fold higher and serum chromium 2.6-fold higher than in the resurfacing arm. Due to these excessively high metal ion levels, the authors recommend against further use of this particular large-head total hip arthroplasty. Level I, randomized clinical trial. See Guidelines for Authors for a complete description of levels of evidence.

  17. Treatment for Periprosthetic Cyst after Total Hip Arthroplasty: Analysis of Six Cases.

    Science.gov (United States)

    Cui, Wei-Ding; Fan, Wei-Min; Chen, Zhe-Feng; Liu, Feng

    2016-11-01

    The present study investigates the pathogenesis of periprosthetic cysts after total hip replacement, and explores appropriate treatment appoaches. Six patients with periprosthetic cysts after total hip arthroplasty were treated at the First Affiliated Hospital of Nanjing Medical University between 2009 and 2014. During surgery, it was found that all cysts communicated with the hip and the hip prosthesis could be seen after cyst excision. Four patients simply underwent cyst excision, and light red liquid was found in the cyst. Among them, radiological examination revealed that a part of the hip prosthesis projected from the bone bed in one case. Postoperative pathology revealed a synovial cyst with inflammatory cell infiltration. Prostheses were loosened in two cases, so cystectomy and revision of the prosthesis were performed at the same time. Among the six patients, polyethylene wear particles could be seen in five patients through a pathological polarizing microscope. Out of the four patients who underwent simple cyst excision, two patients experienced cyst recurrence within 1 year after surgery; however, there was no cyst recurrence in the two patients who underwent cyst excision and revision of the prosthesis. The formation of a periprosthetic cyst after hip replacement is likely to be related to polyethylene wear and undesirable prosthesis position; in addition, when treated by simple cyst excision, the rate of recurrence was higher. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  18. Two Different Total Hip Arthroplasties for Hartofilakidis Type C1 Developmental Dysplasia of Hip in Adults

    Institute of Scientific and Technical Information of China (English)

    Ya-Ming Chu; Yi-Xin Zhou; Na Han; De-Jin Yang

    2016-01-01

    Background: Total hip arthroplasty (THA) in developmental dysplasia of the hip (DDH) is more complex than the normal hip, with large replacement risks and many complications.Although nonosteotomy THA is convenient to perform, femoral osteotomy shortening can avoid blood vessel and nerve traction injuries.This study aimed to compare osteotomy THA with nonosteotomy to determine reasonable options for operative management of DDH.Methods: Data on 48 DDH patients who underwent THA were analyzed retrospectively.The patients were divided into two groups: Group A 29 cases (nonosteotomy), and group B 19 cases (osteotomy).Harris and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores, limb length discrepancy (LLD), radiological data on the hip, and claudication were evaluated.Data were analyzed by using paired-sample Student's t-test, independent-sample Student's t-test, and Pearson's Chi-square test;the test level was α =0.05.Results: Postoperative Harris (90.7 ± 5.1) and WOMAC scores (88.0 ± 10.6) were significantly improved compared with preoperative Harris (44.8 ± 5.7) and WOMAC scores (42.0 ± 5.3) in group A (P < 0.05).Postoperative Harris (90.4 ± 2.8) and WOMAC scores (88.2 ± 5.9) were significantly improved compared with preoperative Harris (44.4 ± 4.2) and WOMAC scores (43.2 ± 4.3) in group B (P < 0.05).One case of dislocation occurred in group A;after closed reduction, dislocation did not recur.In group A, 2 patients developed cutaneous branch injury of the femoral nerve, which spontaneously recovered without treatment.Postoperative LLD >2 cm was seen in one case in group A and five cases in group B.Postoperative claudication showed no significant difference between the two groups (P > 0.05).No patients developed infection;postoperative X-rays showed that the location of the prosthesis was satisfactory, and the surrounding bone was not dissolved.Conclusions: THA is effective and safe for DDH.For unilateral high dislocation

  19. [Ceramic-on-ceramic bearings in total hip arthroplasty (THA)].

    Science.gov (United States)

    Sentürk, U; Perka, C

    2015-04-01

    The main reason for total hip arthroplasty (THA) revision is the wear-related aseptic loosening. Younger and active patients after total joint replacement create high demands, in particular, on the bearings. The progress, especially for alumina ceramic-on-ceramic bearings and mixed ceramics have solved many problems of the past and lead to good in vitro results. Modern ceramics (alumina or mixed ceramics containing alumina) are extremely hard, scratch-resistant, biocompatible, offer a low coefficient of friction, superior lubrication and have the lowest wear rates in comparison to all other bearings in THA. The disadvantage of ceramic is the risk of material failure, i.e., of ceramic fracture. The new generation of mixed ceramics (delta ceramic), has reduced the risk of head fractures to 0.03-0.05 %, but the risk for liner fractures remains unchanged at about 0.02 %. Assuming a non-impinging component implantation, ceramic-on-ceramic bearings have substantial advantages over all other bearings in THA. Due to the superior hardness, ceramic bearings produce less third body wear and are virtually impervious to damage from instruments during the implantation process. A specific complication for ceramic-on-ceramic bearings is "squeaking". The high rate of reported squeaking (0.45 to 10.7 %) highlights the importance of precise implant positioning and the stem and patient selection. With precise implant positioning this problem is rare with many implant designs and without clinical relevance. The improved tribology and the presumable resulting implant longevity make ceramic-on-ceramic the bearing of choice for young and active patients. Georg Thieme Verlag KG Stuttgart · New York.

  20. Staged Custom, Intramedullary Antibiotic Spacers for Severe Segmental Bone Loss in Infected Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Atul F. Kamath

    2011-01-01

    Full Text Available Introduction. Total hip arthroplasty (THA infections with severe bone loss pose significant reconstructive challenges. We present our experience with two-stage hip reimplantation using an intramedullary, antibiotic-impregnated nail. Methods. Three patients with infected THA with severe proximal femoral bone loss (Mallory type IIIB or greater were treated using a custom antibiotic spacer. Clinical outcomes and any complications were recorded. Average followup was 49 months from final reimplantation. Results. Mean age at spacer placement (stage 1 was 53 years. The mean Harris Hip Score at final followup was 80. Two patients had asymptomatic heterotopic ossification, and one patient had a 2 cm leg-length discrepancy. Conclusions. A custom intramedullary nail antibiotic spacer is a reliable option in the staged management of the infected THA with severe proximal femoral bone loss. Benefits of this technique include limb salvage with maintenance of leg length, soft tissue tension, and functional status.

  1. Hip resurfacing versus total hip arthroplasty: a systematic review comparing standardized outcomes.

    Science.gov (United States)

    Marshall, Deborah A; Pykerman, Karen; Werle, Jason; Lorenzetti, Diane; Wasylak, Tracy; Noseworthy, Tom; Dick, Donald A; O'Connor, Greg; Sundaram, Aish; Heintzbergen, Sanne; Frank, Cy

    2014-07-01

    Metal-on-metal hip resurfacing was developed for younger, active patients as an alternative to THA, but it remains controversial. Study heterogeneity, inconsistent outcome definitions, and unstandardized outcome measures challenge our ability to compare arthroplasty outcomes studies. We asked how early revisions or reoperations (within 5 years of surgery) and overall revisions, adverse events, and postoperative component malalignment compare among studies of metal-on-metal hip resurfacing with THA among patients with hip osteoarthritis. Secondarily, we compared the revision frequency identified in the systematic review with revisions reported in four major joint replacement registries. We conducted a systematic review of English language studies published after 1996. Adverse events of interest included rates of early failure, time to revision, revision, reoperation, dislocation, infection/sepsis, femoral neck fracture, mortality, and postoperative component alignment. Revision rates were compared with those from four national joint replacement registries. Results were reported as adverse event rates per 1000 person-years stratified by device market status (in use and discontinued). Comparisons between event rates of metal-on-metal hip resurfacing and THA are made using a quasilikelihood generalized linear model. We identified 7421 abstracts, screened and reviewed 384 full-text articles, and included 236. The most common study designs were prospective cohort studies (46.6%; n = 110) and retrospective studies (36%; n = 85). Few randomized controlled trials were included (7.2%; n = 17). The average time to revision was 3.0 years for metal-on-metal hip resurfacing (95% CI, 2.95-3.1) versus 7.8 for THA (95% CI, 7.2-8.3). For all devices, revisions and reoperations were more frequent with metal-on-metal hip resurfacing than THA based on point estimates and CIs: 10.7 (95% CI, 10.1-11.3) versus 7.1 (95% CI, 6.7-7.6; p = 0.068), and 7.9 (95% CI, 5.4-11.3) versus 1

  2. Periprosthetic fracture of the acetabulum after total hip arthroplasty.

    Science.gov (United States)

    Peterson, C A; Lewallen, D G

    1996-08-01

    Eleven patients who had sustained a periprosthetic fracture of the acetabulum at a mean of 6.2 years (range, one month to thirteen years) after a total hip arthroplasty were managed at our institution between 1985 and 1991. Five patients had a fracture of the medial wall; three, a fracture of the posterior column; two, a transverse fracture; and one, a fracture of the anterior column. Six fractures were displaced by two millimeters or more. Eight fractures were caused by blunt trauma or a fall, and three occurred spontaneously. A fracture was classified as type 1 if the acetabular component was clinically and radiographically stable (eight patients) and as type 2 if the component was unstable (three patients). One patient, who had a displaced type-2 fracture of the posterior column, died of an associated intrapelvic vascular injury. The other two patients who had a type-2 fracture were managed with revision of the acetabular component without supplemental plate fixation, immediately after the diagnosis of the fracture. The eight patients who had a type-1 fracture initially were managed with limitation of weight-bearing or modification of activity; in six of these patients, the fracture united without additional treatment. The ten surviving patients were followed for a mean of sixty-two months after the fracture. Eight of these patients-including four in whom a type-1 fracture had united after non-operative treatment-had a revision of the acetabular component because of pain, loosening, or non-union by the time of the most recent follow-up. Two patients (one of whom had a type-1 fracture and the other, a type-2 fracture) had multiple revisions of the acetabular component; both had supplemental internal fixation with a plate. All ten patients ultimately had a stable, functioning prosthesis. We conclude that periprosthetic acetabular fractures are associated with a poor prognosis with regard to the survival of the acetabular component but that it is possible to

  3. 3D Printing Aids Acetabular Reconstruction in Complex Revision Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Andrew J. Hughes

    2017-01-01

    Full Text Available Revision hip arthroplasty requires comprehensive appreciation of abnormal bony anatomy. Advances in radiology and manufacturing technology have made three-dimensional (3D representation of osseous anatomy obtainable, which provide visual and tactile feedback. Such life-size 3D models were manufactured from computed tomography scans of three hip joints in two patients. The first patient had undergone multiple previous hip arthroplasties for bilateral hip infections, resulting in right-sided pelvic discontinuity and a severe left-sided posterosuperior acetabular deficiency. The second patient had a first-stage revision for infection and recurrent dislocations. Specific metal reduction protocols were used to reduce artefact. The images were imported into Materialise MIMICS 14.12®. The models were manufactured using selective laser sintering. Accurate templating was performed preoperatively. Acetabular cup, augment, buttress, and cage sizes were trialled using the models, before being adjusted, and resterilised, enhancing the preoperative decision-making process. Screw trajectory simulation was carried out, reducing the risk of neurovascular injury. With 3D printing technology, complex pelvic deformities were better evaluated and treated with improved precision. Life-size models allowed accurate surgical simulation, thus improving anatomical appreciation and preoperative planning. The accuracy and cost-effectiveness of the technique should prove invaluable as a tool to aid clinical practice.

  4. 3D Printing Aids Acetabular Reconstruction in Complex Revision Hip Arthroplasty

    Science.gov (United States)

    DeBuitleir, Cathal; Soden, Philip; O'Donnchadha, Brian; Tansey, Anthony; Abdulkarim, Ali; McMahon, Colm; Hurson, Conor J.

    2017-01-01

    Revision hip arthroplasty requires comprehensive appreciation of abnormal bony anatomy. Advances in radiology and manufacturing technology have made three-dimensional (3D) representation of osseous anatomy obtainable, which provide visual and tactile feedback. Such life-size 3D models were manufactured from computed tomography scans of three hip joints in two patients. The first patient had undergone multiple previous hip arthroplasties for bilateral hip infections, resulting in right-sided pelvic discontinuity and a severe left-sided posterosuperior acetabular deficiency. The second patient had a first-stage revision for infection and recurrent dislocations. Specific metal reduction protocols were used to reduce artefact. The images were imported into Materialise MIMICS 14.12®. The models were manufactured using selective laser sintering. Accurate templating was performed preoperatively. Acetabular cup, augment, buttress, and cage sizes were trialled using the models, before being adjusted, and resterilised, enhancing the preoperative decision-making process. Screw trajectory simulation was carried out, reducing the risk of neurovascular injury. With 3D printing technology, complex pelvic deformities were better evaluated and treated with improved precision. Life-size models allowed accurate surgical simulation, thus improving anatomical appreciation and preoperative planning. The accuracy and cost-effectiveness of the technique should prove invaluable as a tool to aid clinical practice. PMID:28168060

  5. Complications of total hip arthroplasty: periprosthetic fractures of the acetabulum.

    Science.gov (United States)

    Chitre, Amol; Wynn Jones, Henry; Shah, Nikhil; Clayson, Anthony

    2013-12-01

    Periprosthetic fractures of the acetabulum are a rare but potentially disastrous complication of total hip arthroplasty. Such fractures occur either as early perioperative complications or late complications when they are associated with either significant trauma or as a result of the loss of the structural integrity of the bone supporting the prosthesis, such as aseptic osteolysis. The incidence of such fractures appears to be increasing with the increased use of uncemented acetabular components. This article explores the current literature on the epidemiology, etiology, and classification of periprosthetic acetabular fractures as well as offering potential treatment strategies.

  6. Transfusion-Transmitted Babesiosis During Total Hip Arthroplasty.

    Science.gov (United States)

    Carnevale, Joseph; Feller, Ross; Shalvoy, Robert M

    2015-09-01

    Babesiosis is a potentially life-threatening zoonotic disease that is endemic to the northeastern United States and increasing in prevalence worldwide. Transmitted by the same Ixodes tick responsible for Lyme disease, the intraerythrocytic parasite Babesia causes a wide range of clinical presentations--from asymptomatic carriage to a fulminant course with rapid deterioration. Symptoms typically present 1 to 6 weeks after inoculation, with the gradual onset of fatigue, malaise, weakness, and intermittent or sustained fever as high as 40.9°C. Severe cases are associated with parasitemia greater than 4%, alkaline phosphatase greater than 125 U/L, and white blood cell counts greater than 5×10(9)/L. Definitive diagnosis is made by microscopic examination of thin blood smears, polymerase chain reaction, and indirect immunofluorescent antibody testing. The increasing frequency of babesiosis paired with a lack of blood-donor screening assays poses a serious threat to the safety of the US blood supply. Although babesiosis is responsible for 3.6% of transfusion-related deaths, the Food and Drug Administration has yet to approve mandatory screening for the parasite in donated blood. Historically, transfusion-transmitted babesiosis has been thought to be isolated to the immunocompromised patient population. However, a recent case of transfusion-transmitted babesiosis in an immunocompetent patient following total hip arthroplasty is the first reported in the literature and may represent a growing risk to a far greater segment of the population than previously thought. This article summarizes the current state of transfusion-transmitted babesiosis and the detrimental impact of this infection on blood transfusion safety. Copyright 2015, SLACK Incorporated.

  7. Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty.

    Science.gov (United States)

    Lusty, P J; Tai, C C; Sew-Hoy, R P; Walter, W L; Walter, W K; Zicat, B A

    2007-12-01

    Wear debris has been implicated in the pathogenesis of osteolysis. Alumina-on-alumina ceramic bearings have a low wear rate, which may reduce the prevalence of osteolysis. The purpose of this study was to determine the rates of wear and osteolysis associated with modern cementless hip arthroplasty with alumina-on-alumina bearings at five years. We analyzed a series of 301 third-generation alumina-on-alumina cementless primary total hip replacements in 283 patients. The average age of the patients at the time of the arthroplasty was fifty-eight years. All procedures were performed with use of the same surgical technique and the same implant at a single center. At a minimum of five years postoperatively, ten patients had died and twenty-two patients were lost to follow-up. We assessed patients clinically and radiographically, and all retrieved bearings were analyzed for wear. At the time of the latest follow-up, the mean Harris hip score was 95 points. All surviving implants had radiographic evidence of stable bone ingrowth. There were nine revisions of one or both components. Four stems were revised following periprosthetic fracture, one stem was revised because of aseptic loosening at two months, and one stem was revised to facilitate a femoral shortening osteotomy. Two cups were revised because of psoas tendinitis, and both components of one arthroplasty were revised because of impingement and osteolysis. The rate of survival of both components, with revision because of aseptic loosening or osteolysis as the end point, was 99% at seven years. The retrieved femoral heads showed an early median wear rate of 0.2 mm(3) per year. Cementless primary total hip prostheses with a third-generation alumina-on-alumina bearing showed very low wear and were associated with minimal osteolysis at the time of follow-up, at a minimum of five years.

  8. Reliability of using DXA around RTHAs. Bone Mineral Density of the femoral neck in resurfacing hip arthroplasty

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Ovesen, Ole; Brixen, Kim;

    2010-01-01

      Background and purpose: Resurfacing Total Hip Arthroplasty (RTHA) may preserve the femoral neck bone-stock post-operatively. Bone Mineral Density (BMD), could theoretically be affected by the hip-position, and bias longitudinal studies. We aimed to investigate BMD precision dependency on type...... of ROI and position of hip. Method: We DXA scanned the femoral neck of 15 resurfacing patients twice with the hip in 3 different rotations; 15° internal, neutral, and 15° external. For each position BMD was analyzed with 3 different surface area models. One model measured BMD in the total femoral neck......, the second model divided the neck in two and the third model had 6 divisions. Results: When all hip positions were pooled a mean Coefficient of variation (CV) of 3.1%, 3.6% and 4.6% was found in the 1, 2 and 6-region models, respectively, The external rotated hip position was less reproducible. When the hip...

  9. Fatal cobalt toxicity after total hip arthroplasty revision for fractured ceramic components.

    Science.gov (United States)

    Fox, Kimberly A; Phillips, Todd M; Yanta, Joseph H; Abesamis, Michael G

    2016-11-01

    Post-arthroplasty metallosis, which refers to metallic corrosion and deposition of metallic debris in the periprosthetic soft tissues of the body, is an uncommon complication. Systemic cobalt toxicity post-arthroplasty is extremely rare. The few known fatal cases of cobalt toxicity appear to be a result of replacing shattered ceramic heads with metal-on-metal or metal-on-polyethylene implants. Friction between residual shards of ceramic and cobalt-chromium implants allows release of cobalt into the synovial fluid and bloodstream, resulting in elevated whole blood cobalt levels and potential toxicity. This is a single patient chart review of a 60-year-old woman with prior ceramic-on-ceramic right total hip arthroplasty complicated by fractured ceramic components and metallosis of the joint. She underwent synovectomy and revision to a metal-on-polyethylene articulation. Ten months post-revision, she presented to the emergency department (ED) with right hip pain, dyspnea, worsening hearing loss, metallic dysgeusia, and weight loss. Chest CTA revealed bilateral pulmonary emboli (PE), and echocardiogram revealed new cardiomyopathy with global left ventricular hypokinesis with an ejection fraction (EF) of 35-40% inconsistent with heart strain from PE. Whole blood cobalt level obtained two days into her admission was 424.3 mcg/L and 24-h urine cobalt level was 4830.5 mcg/L. Although the patient initially clinically improved with regard to her PE and was discharged to home on hospital day 5, she returned 10 days later with a right hip dislocation and underwent closed reduction of the hip. The patient subsequently decompensated, developing cardiogenic shock, and respiratory failure. She went into pulseless electrical activity (PEA) and expired. Autopsy revealed an extensive metallic effusion surrounding the right hip prosthesis that tested positive for cobalt (41,000 mcg/L). There was also cobalt in the heart muscle tissue (2.5 mcg/g). A whole blood cobalt level

  10. Comparative study of extended versus short term thromboprophylaxis in patients undergoing elective total hip and knee arthroplasty in Indian population

    Directory of Open Access Journals (Sweden)

    Velu Nair

    2013-01-01

    Results: In the prospective arm, only 1 patient developed symptomatic PTE compared to 26 (3.27% cases of VTE (20 cases of PTE and 6 cases of DVT in the retrospective group. Conclusion: Extended thromboprophylaxis (for 4 weeks was found to be more effective than short term thromboprophylaxis in minimizing the risk of postoperative VTE in patients who underwent THA/TKA.

  11. Treatment of Crowe Type-IV Hip Dysplasia Using Cementless Total Hip Arthroplasty and Double Chevron Subtrochanteric Shortening Osteotomy: A 5- to 10-Year Follow-Up Study.

    Science.gov (United States)

    Li, Xigong; Lu, Yang; Sun, Junying; Lin, Xiangjin; Tang, Tiansi

    2017-02-01

    The purpose of this study was to evaluate the functional and radiographic results of patients with Crowe type-IV hip dysplasia treated by cementless total hip arthroplasty and double chevron subtrochanteric osteotomy. From January 2000 to February 2006, cementless total hip arthroplasty with a double chevron subtrochanteric shortening osteotomy was performed on 18 patients (22 hips) with Crowe type-IV dysplasia. The acetabular cup was placed in the position of the anatomic hip center, and subtrochanteric femoral shortening osteotomy was performed with the use of a double chevron design. The clinical and radiographic outcomes were reviewed with a mean follow-up of 6.5 years (5-10 years). The mean amount of femoral subtrochanteric shortening was 38 mm (25-60 mm). All osteotomy sites were healed by 3-6 months without complications. The mean Harris Hip Score improved significantly from 47 points (35-65 points) preoperatively to 88 points (75-97 points) at the final follow-up. The Trendelenburg sign was corrected from a positive preoperative status to a negative postoperative status in 12 of 22 hips. No acetabular and femoral components have loosened or required revision during the period of follow-up. Cementless total hip arthroplasty using double chevron subtrochanteric osteotomy allowed for restoration of anatomic hip center with safely functional limb lengthening, achieved correction of preoperative limp, and good functional and radiographic outcomes for 22 Crowe type-IV dislocation hips at the time of the 5- to 10-year follow-up. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Late repair of abductor avulsion after the transgluteal approach for hip arthroplasty.

    Science.gov (United States)

    Miozzari, Hermes H; Dora, Claudio; Clark, John M; Nötzli, Hubert P

    2010-04-01

    The abductor release sometimes does not heal after a transgluteal approach for hip arthroplasty. Factors influencing the success of subsequent repair are unclear. We used magnetic resonance imaging (MRI) to compare the condition of the gluteus medius with clinical outcome after late repair of abductor dehiscence in 12 total hip patients. Evaluation included a pain rating, gait evaluation, Trendelenburg test, strength grading, and Harris Hip Score. Most had both prerepair and postrepair MRI studies to assess the repair and to grade abductor muscle fatty degeneration. Two repairs without MRI were explored surgically. Although average pain, limp, and strength scores improved significantly, rerupture occurred in 4 subjects and fatty degeneration in the gluteus medius did not improve, even with intact repair. Nine patients were satisfied; 7 of these had an intact repair. Magnetic resonance imaging and operative observations suggest that chronic degeneration in the abductor mechanism is the major impediment to successful repair.

  13. Cementless arthroplasty with a distal femoral shortening for the treatment of Crowe type IV developmental hip dysplasia.

    Science.gov (United States)

    Guo, Chang-Yong; Liang, Bo-Wei; Sha, Mo; Kang, Liang-Qi; Wang, Jiang-Ze; Ding, Zhen-Qi

    2015-01-01

    Severe developmental dysplasia of the hip is a surgical challenge. The purpose of this study is to describe the cementless arthroplasty with a distal femoral shortening osteotomy for Crowe type IV developmental hip dysplasia and to report the results of this technique. 12 patients (2 male and 10 female) of Crowe type IV developmental hip dysplasia operated between January 2005 and December 2010 were included in the study. All had undergone cementless arthroplasty with a distal femoral shortening osteotomy. Acetabular cup was placed at the level of the anatomical position in all the hips. The clinical outcomes were assessed and radiographs were reviewed to evaluate treatment effects. The mean followup for the 12 hips was 52 months (range 36-82 months). The mean Harris hip score improved from 41 points (range 28-54) preoperatively to 85 points (range 79-92) at the final followup. The mean length of bone removed was 30 mm (range 25-40 mm). All the osteotomies healed in a mean time of 13 weeks (range 10-16 weeks). There were no neurovascular injuries, pulmonary embolism or no infections. Our study suggests that cementless arthroplasty with a distal femoral shortening is a safe and effective procedure for severe developmental dysplasia of the hip.

  14. Newer Anesthesia and Rehabilitation Protocols Enable Outpatient Hip Replacement in Selected Patients

    OpenAIRE

    Berger, Richard A; Sanders, Sheila A.; Thill, Elizabeth S.; Sporer, Scott M.; Della Valle, Craig

    2009-01-01

    Advancements in the surgical approach, anesthetic technique, and the initiation of rapid rehabilitation protocols have decreased the duration of hospitalization and subsequent length of recovery following elective total hip arthroplasty. We assessed the feasibility and safety of outpatient total hip arthroplasty in 150 consectutive patients. A comprehensive perioperative anesthesia and rehabilitation protocol including preoperative teaching, regional anesthesia, and preemptive oral analgesia ...

  15. The effect of posterior capsule repair upon post-operative hip dislocation following primary total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Wang Chen-Ti

    2008-02-01

    Full Text Available Abstract Background Herein, we evaluated, retrospectively, the effect of posterior capsular repair upon postoperative hip dislocation subsequent to total hip arthroplasty (THA incorporating a posterolateral approach. Methods A total of 181 patients undergoing 204 primary non-complicated THA surgical procedures in the period from January 2000 to October 2005 inclusively were included in this study. The patients were separated into two groups by whether the posterior capsular repair had been incorporated in the surgical procedure. For the surgeon did not commence repairing the posterior capsule until July, 2003, all members in the group that did not undergo posterior capsular repair (142 hips from 131 patients were collected since January, 2000 to July, 2003, while the members in the group that underwent posterior capsular repair (62 hips from 52 patients were followed since July, 2003, to October, 2005. With a minimum follow-up period of 12 months, we evaluated the early post-operative dislocation rate. Results The early postoperative hip-dislocation rate for the group who did not undergo posterior capsular repair appeared to be substantially greater (6.38% versus 0% than the corresponding figure for the group the members of which underwent posterior capsular repair. In addition, patient demographics and the orientation of acetabular components for the replaced hip joints, as presented in postoperative radiographs, did not differ between the two groups. Conclusion Thus, surgeons should include posterior capsular repair as an important step in the surgical procedures of posterolateral approach for all THA in order to reduce the likelihood of early hip dislocation subsequent to THA.

  16. Intraoperative dislocation of the trial bipolar cup into the pelvis during bipolar hip arthroplasty - A case report.

    Science.gov (United States)

    Miyake, Takahito; Kanda, Akio; Morohashi, Itaru; Obayashi, Osamu; Mogami, Atsuhiko; Kaneko, Kazuo

    2017-06-01

    Bipolar hip arthroplasty is a good option for treating femoral neck fractures, although some contraindications have been indicated. We report a case of intraoperative dislocation of the trial bipolar cup into the pelvis during bipolar hip arthroplasty. A 74-year-old woman underwent bipolar hip arthroplasty for a femoral neck fracture (AO31-B2). She was placed in a lateral decubitus position, and a direct lateral approach was used. During intraoperative trial reduction, the trial bipolar cup became disengaged and dislocated into the anterior space of hip joint. Several attempts to retrieve it failed. The permanent femoral component was inserted, and the wound was closed. The patient was repositioned supine to allow an ilioinguinal approach, and the component was easily removed. She had an uneventful, good recovery. Several cases of intraoperative dislocation of the femoral trial head during total hip arthroplasty have been reported, this is the first report of dislocation of a bipolar trial cup. A previous report described difficulty retrieving a trial cup. We easily removed our trial cup using another approach. It is vital to plan systematically for this frustrating complication.

  17. Análise da qualidade de vida de pacientes osteoartrósicos submetidos à artroplastia total do quadril Analysis on quality of life of patients with osteoarthrosis undergoing total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Elmano de Araújo Loures

    2012-01-01

    Full Text Available OBJETIVO: O objetivo do estudo foi a avaliação da qualidade de vida relacionada com a saúde em pacientes afetados por osteoartrose do quadril e tratados por artroplastia total do quadril. MÉTODOS: Estudou-se, prospectivamente, uma coorte de 38 pacientes operados em hospital universitário de referência regional pelo mesmo cirurgião no ano de 2010 e acompanhados durante, no mínimo, seis meses até atingirem reabilitação satisfatória. Cada paciente respondeu ao formulário SF-36 e teve o Harris Hip Score estabelecido imediatamente antes da operação e aos seis meses de seguimento. Os resultados dos testes pré e pós-operatórios foram analisados e comparados com a literatura. RESULTADOS: Os resultados pré e pós-operatórios do SF-36 foram: capacidade funcional - 13,4-53,7; limitação por aspectos físicos - 9,21-48,0; dor - 23,1-62,6; estado geral de saúde - 54,2-71,3; vitalidade - 40,3-69,9; aspectos sociais - 40,8-74,3; limitação por aspectos emocionais - 23,7-64,9; saúde mental - 52,6-80,4. O Harris Hip Score variou de 36,1 a 92,1, em média. Todos os resultados foram estatisticamente significantes (p OBJECTIVE: The aim of the study was to evaluate the health-related quality of life among patients affected by hip osteoarthrosis who were treated by means of total hip arthroplasty. METHODS: A cohort of 38 patients operated by a single surgeon in a regional referential teaching hospital during the year 2010 was prospectively studied and followed up for at least six months until they had achieved satisfactory rehabilitation. Each patient gave responses to the SF-36 form immediately before the operation and six months later and the Harris Hip Score was obtained at the same time. The pre and postoperative results were analyzed and compared with the literature. RESULTS: The pre and postoperative SF-36 results were as follows: physical function: 13.4-53.7; role physical: 9.21-48.0; body pain: 23.1-62.6; general health: 54

  18. Risk of dislocation using large- vs. small-diameter femoral heads in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Plate Johannes F

    2012-10-01

    Full Text Available Abstract Background Dislocation remains a difficult problem in total hip arthroplasty. Large-diameter femoral heads may lower the incidence of dislocation by enhancing the jump distance and decreasing impingement, but their performance against small-diameter heads has not been assessed. This study compared the mid-term radiographic and functional outcomes of two matched cohorts of patients undergoing total hip arthroplasty who had a high pre-operative risk for dislocation and who received either small-diameter (26- or 28-millimeters or large-diameter (≥36-millimeters femoral heads. Methods All patients who received large-diameter heads (≥36-millimeter between 2002 and 2005, and who had pre-operative risk factors for dislocation, were identified in the institution’s joint registry. Forty-one patients (52 hips who received large-diameter heads were identified, and these patients were matched to 48 patients (52 hips in the registry who received small-diameter femoral heads. Results At mean final follow-up of 62 months (range, 49 to 101 months, both groups achieved excellent functional outcomes as measured by Harris Hip scores, with slightly better final scores in the large-diameter group (90 vs. 83 points. No patient showed any radiographic signs of loosening. No patient dislocated in the large-diameter femoral head group; the smaller-diameter group had a greater rate of dislocation (3.8%, 2 out of 52. Conclusions Large-diameter femoral head articulations may reduce dislocation rates in patients who have a high pre-operative risk for dislocation while providing the same functional improvements and safety as small-diameter bearings.

  19. Fast-track hip and knee arthroplasty: clinical and organizational aspects

    DEFF Research Database (Denmark)

    Husted, Henrik

    2012-01-01

    Fast-track hip and knee arthroplasty aims at giving the patients the best available treatment at all times, being a dynamic entity. Fast-track combines evidence-based, clinical features with organizational optimization including a revision of traditions resulting in a streamlined pathway from......; patient-characteristics to predict outcome; and traditions which may be barriers in optimizing outcomes. Patients should be informed and motivated to be active participants and their expectations should be modulated in order to improve satisfaction. Also, organizational aspects need to be analyzed...... and optimized. New logistical approaches should be implemented; the ward ideally (re)structured to only admit arthroplasties; the staff educated to have a uniform approach; extensive preoperative information given including discharge criteria and intended length of stay. This thesis includes 9 papers...

  20. Does BMI influence hospital stay and morbidity after fast-track hip and knee arthroplasty?

    DEFF Research Database (Denmark)

    Husted, Henrik; Jørgensen, Christoffer C.; Gromov, Kirill;

    2016-01-01

    patients only) was associated with a LOS of >4 days (p = 0.001), but not with re-admission. No such relationship existed for TKA. Interpretation - A fast-track setting resulted in similar length of hospital stay and re-admission rates regardless of BMI, except for very obese and morbidly obese THA patients.......Background and purpose - Body mass index (BMI) outside the normal range possibly affects the perioperative morbidity and mortality following total hip arthroplasty (THA) and total knee arthroplasty (TKA) in traditional care programs. We determined perioperative morbidity and mortality....... Complete 90-day follow-up was achieved using national registries and review of medical records. Patients were grouped according to BMI as being underweight, of normal weight, overweight, obese, very obese, and morbidly obese. Results - Median length of stay (LOS) was 2 (IQR: 2-3) days in all BMI groups. 30...

  1. Delayed cementless total hip arthroplasty for neglected dislocation of hip combined with complex acetabular fracture and deficient bone stock

    Institute of Scientific and Technical Information of China (English)

    Ashok S Gavaskar; Naveen Chowdary Tummala

    2012-01-01

    Total hip arthroplasty (THA) for an untreated acetabular fracture is technically challenging and the long-term result is not so favorable.A 45-year-old female patient with untreated column and comminuted posterior wall fracture of the acetabulum was treated in our institution by reconstruction of the posterior wall using iliac strut autograft and plate stabilization of the posterior column with cancellous grafting and cementless THA in a single stage.At 3 years' follow-up,the patient was independently mobile without limb length discrepancy.Radiological evaluation showed well integrated components and bone grafts.No evidence of aseptic loosening or osteolysis was found.This report aims to emphasize that bony acetabular reconstruction allows the use of primary hip components,which improves prosthesis longevity and preserves bone stock for a future revision.

  2. Hip resurfacing arthroplasty: A new method to assess and quantify learning phase.

    Science.gov (United States)

    Aulakh, T S; Jayasekera, N; Singh, R; Patel, A; Kuiper, J H; Richardson, J B

    2014-09-01

    Hip resurfacing had initially gained acceptance and popularity as it helps preserve femoral bone stock. In this study we tried to answer the following questions; 1. Whether there is a learning curve for hip resurfacing? 2. Is it present in surgeons from non-developer centres? 3. Is it present in surgeons from developer centres as well? The Oswestry outcome centre was setup to serve an independent international registry for collecting, analysing and reporting outcomes following hip resurfacing. Over a 10 year period, 4535 patients (5000 hips) were recruited from different countries and within the UK from different centres in this study by 139 surgeons from 37 different countries. Our study has shown that function can be used to assess the level of surgical competence. The results from this multilevel analysis have helped to answer the questions posed in the introduction. Hip resurfacing is a surgical procedure with a learning phase and this learning effect is more pronounced in non-developer surgeons as compared to developer surgeons. Hip scores can be used to assess proficiency and competence of surgeons undertaking hip resurfacing arthroplasty.

  3. Intellijoint HIP®: a 3D mini-optical navigation tool for improving intraoperative accuracy during total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Paprosky WG

    2016-11-01

    Full Text Available Wayne G Paprosky,1,2 Jeffrey M Muir3 1Department of Orthopedics, Section of Adult Joint Reconstruction, Department of Orthopedics, Rush University Medical Center, Rush–Presbyterian–St Luke’s Medical Center, Chicago, 2Central DuPage Hospital, Winfield, IL, USA; 3Intellijoint Surgical, Inc, Waterloo, ON, Canada Abstract: Total hip arthroplasty is an increasingly common procedure used to address degenerative changes in the hip joint due to osteoarthritis. Although generally associated with good results, among the challenges associated with hip arthroplasty are accurate measurement of biomechanical parameters such as leg length, offset, and cup position, discrepancies of which can lead to significant long-term consequences such as pain, instability, neurological deficits, dislocation, and revision surgery, as well as patient dissatisfaction and, increasingly, litigation. Current methods of managing these parameters are limited, with manual methods such as outriggers or calipers being used to monitor leg length; however, these are susceptible to small intraoperative changes in patient position and are therefore inaccurate. Computer-assisted navigation, while offering improved accuracy, is expensive and cumbersome, in addition to adding significantly to procedural time. To address the technological gap in hip arthroplasty, a new intraoperative navigation tool (Intellijoint HIP® has been developed. This innovative, 3D mini-optical navigation tool provides real-time, intraoperative data on leg length, offset, and cup position and allows for improved accuracy and precision in component selection and alignment. Benchtop and simulated clinical use testing have demonstrated excellent accuracy, with the navigation tool able to measure leg length and offset to within <1 mm and cup position to within <1° in both anteversion and inclination. This study describes the indications, procedural technique, and early accuracy results of the Intellijoint HIP

  4. The prevention of periprosthetic fractures of the femur during and after total hip arthroplasty.

    Science.gov (United States)

    Mitchell, Philip A; Greidanus, Nelson V; Masri, Bassam A; Garbuz, Donald S; Duncan, Clive P

    2003-01-01

    The increasing prevalence of periprosthetic fractures of the femur associated with total hip arthroplasty (THA) is caused by several factors, including the increasing use of cementless prostheses in both primary and revision procedure, the rise in THAs in younger patients, who are more at risk of high-energy trauma, and the increasing longevity of elderly patients after THA. With approximately 200,000 THAs performed annually in North America, fracture prevention is extremely important for the individual patient and has a significant impact on the health care system.

  5. Sex differences in the morphological failure patterns following hip resurfacing arthroplasty

    Directory of Open Access Journals (Sweden)

    Rüther Wolfgang

    2011-10-01

    Full Text Available Abstract Background Metal-on-metal hybrid hip resurfacing arthroplasty (with a cementless acetabular component and a cemented femoral component is offered as an alternative to traditional total hip arthroplasty for the young and active adult with advanced osteoarthritis. Although it has been suggested that women are less appropriate candidates for metal-on-metal arthroplasty, the mechanisms of prosthesis failure has not been fully explained. While specific failure patterns, particularly osteonecrosis and delayed type hypersensitivity reactions have been suggested to be specifically linked to the sex of the patient, we wished to examine the potential influence of sex, clinical diagnosis, age of the patient and the size of the femoral component on morphological failure patterns in a large cohort of retrieved specimens following aseptic failure of hip resurfacing arthroplasty. Methods Femoral remnants retrieved from 173 hips with known patient's sex were morphologically analyzed for the cause of failure. The results were compared with the control group of the remaining 31 failures from patients of unknown sex. The odds ratios (OR and 95% confidence intervals (CI of the following morphologically defined variables were calculated using logistic regression analysis: periprosthetic fractures (n = 133, osteonecrosis (n = 151, the presence of excessive intraosseous lymphocyte infiltration (n = 11, and interface hyperosteoidosis (n = 30. Logistic regression analysis was performed both unadjusted and after adjustment for sex, age, the size of the femoral component, and preoperative clinical diagnosis. Results Femoral remnants from female patients had a smaller OR for fracture (adjusted OR: 0.29, 95% CI 0.11, 0.80, P for difference = 0.02 and for the presence of osteonecrosis (adjusted OR: 0.16, 95% CI 0.04, 0.63, P for difference = 0.01. However, women had a higher OR for both the presence of excessive intraosseous lymphocyte infiltration (adjusted OR: 10

  6. 终末期肾病患者行髋关节置换的特征%Characteristics of total hip arthroplasty in patients with end stage renal disease

    Institute of Scientific and Technical Information of China (English)

    庄泽; 李智勇; 陈郁鲜; 任建华; 何容涵; 赵家尧; 王昆

    2013-01-01

    avascular necrosis and other diseases. The patients with end stage renal disease have the characteristics that different to general hip joint replacement when having total hip arthroplasty. OBJECTIVE: To observe the characteristics of biological or cementless total hip arthroplasty for the treatment of end stage renal disease combined with hip diseases. METHODS: The clinical data of 15 end stage renal disease patients with hip disease (four males and 11 females) who received total hip arthroplasty or artificial femoral head replacement in the Third Affiliated Hospital of Sun Yat-sen University from June 2006 to March 2012 were retrospectively reviewed. There were eight cases of femoral neck fracture (one case of bilateral femoral neck fracture), five cases of femoral head avascular necrosis, two cases of osteoarthritis, total y 16 hips. The joint replacement included total hip arthroplasty in nine hips (cementless type five hips, cemented type four hips) and hemiarthroplasty in seven hips (cementless type two hips, cemented type five hips). The fol ow-up X-ray film was taken to observe whether the translucent zone could be seen around the prosthesis, as wel as the dynamic changes, and the Harris hip score and SF-36 score were used to evaluate the recovery of joint function and improvement of life quality. RESULTS AND CONCLUSION: Patients were fol owed-up for 0.5-4 years after replacement, the fol owed-up time showed skewed distribution, and the median time was 30 months. Harris hip score was increased from preoperative (53.0±5.8) to the last fol ow-up (86.0±3.8). SF-36 score was increased from preoperative (65.0±2.4) to the last fol ow-up (83.0±4.9). There were five cases of complications before discharge, two cases of hypotension shock when undergoing dialysis after replacement, two cases of pulmonary infection, one case of delayed wound union, and al the patients recovered after treatment. No prosthesis loosening, dislocation or prosthesis infection was observed

  7. Mid-term results of the BIOLOX delta ceramic-on-ceramic total hip arthroplasty.

    Science.gov (United States)

    Lee, Y K; Ha, Y C; Yoo, J-I; Jo, W L; Kim, K-C; Koo, K H

    2017-06-01

    We conducted a prospective study of a delta ceramic total hip arthroplasty (THA) to determine the rate of ceramic fracture, to characterise post-operative noise, and to evaluate the mid-term results and survivorship. Between March 2009 and March 2011, 274 patients (310 hips) underwent cementless THA using a delta ceramic femoral head and liner. At each follow-up, clinical and radiological outcomes were recorded. A Kaplan-Meier analysis was undertaken to estimate survival. Four patients (four hips) died and 18 patients (20 hips) were lost to follow-up within five years. The remaining 252 patients (286 hips) were followed for a mean of 66.5 months (60 to 84). There were 144 men (166 hips) and 108 women (120 hips) with a mean age of 49.7 years (16 to 83) at surgery. The mean pre-operative Harris Hip Score of 47.1 points improved to 93.8 points at final follow-up. Six patients reported squeaking in seven hips; however, none were audible. Radiolucent lines involving Gruen zones one and/or seven were seen in 52 hips (18.2%). No hip had detectable wear, focal osteolysis or signs of loosening. One hip was revised because of fracture of the ceramic liner, which occurred due to an undetected malseating of the ceramic liner at the time of surgery. One hip was revised for a periprosthetic fracture of the femur, and one hip was treated for periprosthetic joint infection. The six-year survivorship with re-operation for any reason as the endpoint was 99.0% (95% confidence interval 97.8% to 100%). The rate of delta ceramic fracture was 0.3% (one of 286). While ceramic head fracture was dominant in previous ceramic-on-ceramic THA, fracture of the delta ceramic liner due to malseating is a concern. Cite this article: Bone Joint J 2017;99-B:741-8. ©2017 The British Editorial Society of Bone & Joint Surgery.

  8. Heterotopic Ossification Prophylaxis After Total Hip Arthroplasty: Randomized Trial of 400 vs 700 cGy.

    Science.gov (United States)

    Liu, Jane Z; Frisch, Nicholas B; Barden, Regina M; Rosenberg, Aaron G; Silverton, Craig D; Galante, Jorge O

    2017-04-01

    Heterotopic ossification (HO) is a known complication following total hip arthroplasty. Radiation is an effective prophylaxis, but an optimal protocol has yet to be determined. We performed a randomized, double-blinded clinical trial in high-risk patients to determine the efficacy of 400 vs 700 cGy doses of radiation. One hundred forty-seven patients undergoing total hip arthroplasty and at high risk for HO at an urban medical center were randomized to receive either a single 400 or 700 cGy dose of radiation postoperatively. High risk was defined as a diagnosis of diffuse idiopathic skeletal hyperostosis, hypertrophic osteoarthritis, ankylosing spondylitis, or history of previous HO. Radiation was administered on the first or second postoperative day. A single blinded reviewer graded radiographs taken immediately postoperatively and at a minimum of 6 months postoperatively using the Brooker classification. Progression was defined as an increase in Brooker classification. Operative data including surgical approach, implant fixation, revision surgery, and postoperative range of motion data were also collected. A significantly greater portion of patients who received the 400 cGy dose demonstrated progression of HO than patients who received the 700 cGy dose. There were no wound complications. No preoperative factors were associated with a higher rate of progression. Patients who progressed had less flexion on physical examination than patients who did not progress, but this was not clinically significant. Seven hundred centigray was superior to 400 cGy in preventing HO formation following total hip arthroplasty in high-risk patients and may be the more effective treatment in this population. Further studies comparing 700 cGy to dosages between 400 and 700 cGy may help to clarify if a more optimal dose can be identified. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. [Retrospective analysis on total hip arthroplasty for the treatment of developmental dysplasia of the hip in 29 adults].

    Science.gov (United States)

    Cao, Yin-Sheng; Lu, Min; Yao, Gong-He; Li, Wei-Ning; Zhu, Fu-Ping; Zhang, Bo

    2013-11-01

    To study the results of the total hip arthroplasty (THA) in the treatment of developmental dysplasia of the hip (DDH) with severe osteoarthritis in adults. From March 2004 to February 2011, 29 patients (32 hips) with DDH were treated by THA with an cementless cup. There were 11 males and 18 females,with an average age of 52.6 years (ranging from 37 to 73 years). Unilateral DDH occurred in 26 patients and bilateral DDH occurred in 3 patients. Based on the Crowe classification, there were 18 hips in 17 patients of type I ,7 hips in 6 patients of type II, 4 hips in 3 patients of type III, 3 hips in 3 patients of type IV. Except for 3 patients with bilateral DDH, the other patients' ill lower limbs were 1 to 6 cm shorter than the healthy lower ones. All the patients were followed up,and the duration ranged from 8 months to 5.3 years(averaged 3.7 years) without infection, dislocation, and sciatic nerves injury after the operation. One patient with proximal femoral fracture, intraoperation used wire binding, after 4 years of follow-up, fracture healed without evidence of prosthesis loosening. All grafts and subtrochanteric osteotomy healing were achieved. In 21 patients, the pain was completely relieved and the function of the hip joints was good. Five patients still had mild limping, but reduced significantly than preoperation. In 3 patients, the ill lower limbs were more than 1 cm shorter than the healthy lower ones and the other patients' ill lower limbs were less than 1 cm shorter than the healthy lower ones. Two patients' lower limbs were lengthened 4 to 5 cm. The Harris scores were 43.6 +/- 7.1 preoperatively and 86.7 +/- 5.3 postoperatively (P < 0.05). THA with deepening the medial wall of the acetabulum at the true acetabulum, according to different characteristics of Crowe classification, using different operation program, cementless cup in adult could obtain favorable results.

  10. Soft-tissue balance evaluation system for total hip arthroplasty by intraoperative contact pressure measurement at the hip joint.

    Science.gov (United States)

    Otake, Yoshito; Suzuki, Naoki; Hattori, Asaki; Hayashibe, Mitsuhiro; Miki, Hidenobu; Yamamura, Mitsuyoshi; Sugano, Nobuhiko; Yonenobu, Kazuo; Ochi, Takahiro

    2006-01-01

    We developed a system for measurement of contact pressure at the hip joint surfaces that enables checking of the artificial hip joint condition during surgery. First, we constructed the pressure sensor that forms the artificial joint. We installed eight small pressure sensors to the spherical head component, a part of the ball-socket joint. Next, we developed software for recording and visualizing the detected pressures that were recorded every 1 ms. The pressure distribution was displayed with the 3D computer graphics in real-time. The system enabled intuitive recognition of pressure direction 3-dimensions. Next, using the system, we conducted measurements during total hip arthroplasty. Although it requires some improvements in its measurement accuracy, the system allows real-time acquisition of information on the artificial hip joint in real-time. Further improvements of the calibration method should enable more accurate measurements. As a complete system, it will be a useful tool for selecting an appropriate implant that fits a patient's hip joint or for estimating the risk of complications after surgery.

  11. Analgesic efficacy of local infiltration analgesia in hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Lasse Østergaard; Kehlet, H

    2014-01-01

    clinical trials even when combined with multimodal systemic analgesia. In contrast, LIA may have limited additional analgesic efficacy in THA when combined with a multimodal analgesic regimen. Postoperative administration of local anaesthetic in wound catheters did not provide additional analgesia when......In recent years, there has been an increasing interest in local infiltration analgesia (LIA) as a technique to control postoperative pain. We conducted a systematic review of randomized clinical trials investigating LIA for total knee arthroplasty (TKA) and total hip arthroplasty (THA) to evaluate...... the analgesic efficacy of LIA for early postoperative pain treatment. In addition, the analgesic efficacy of wound catheters and implications for length of hospital stay (LOS) were evaluated. Twenty-seven randomized controlled trials in 756 patients operated on with THA and 888 patients operated on with TKA...

  12. Bone mineral density of the femoral neck in resurfacing hip arthroplasty

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Ovesen, Ole; Brixen, Kim

    2010-01-01

    Resurfacing total hip arthroplasty (RTHA) may preserve the femoral neck bone stock postoperatively. Bone mineral density (BMD) may be affected by the hip position, which might bias longitudinal studies. We investigated the dependency of BMD precision on type of ROI and hip position....

  13. Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

    Directory of Open Access Journals (Sweden)

    Gholam Hossein Shahcheraghi

    2015-09-01

    Full Text Available Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations. Methods: 52 primary cementless total hip arthroplasty in 42 patients with the mean age of 48.8 years were retrospectively studied. Two groups of prosthesis had been implanted: Harris-Galante II (HGII in 15 and Versys-Trilogy (V-T in 37 hips, both from Zimmer company. The patients were assessed clinically, radiographically and with Harris hip score, SF36, WOMAC, and MACTAR questionnaires, with 65 months (26-136 mean follow-up. Results: All the V-T prostheses had survived well. Eight of HG II were revised by the last follow-up in 19-102 months. All had undergone acetabular revision and 2 combined with femoral revision. Broken tines of HGII cups were seen in 4 radiographs. The 65 months overall survival was 96.2% for femoral and 84.6% for acetabular components. 90% had good or excellent Harris hip scores. The functional scores were poorer in the HG II group. Pain relief and improved walking were the two main patients’ expectations fulfilled in 97.6% and 92.8%, respectively. Conclusions: The outcome of cementless total hip arthroplasty (THA is satisfactory and comparable with the literature based on the results of function and survival of this small comparative group. The use of HGII acetabular component should be abandoned.

  14. 全髋表面置换术治疗股骨头坏死短期随访研究%Short-term result of hip resurfacing arthroplasty in the treatment of patients with femoral head necrosis

    Institute of Scientific and Technical Information of China (English)

    何志勇; 狄正林; 陶崑; 章军辉; 冯建翔; 吴海山

    2011-01-01

    Objective:To study short-term results of hip resurfacing arthroplasty (HRA) in the treatment of patients with avascular necrosis of femoral head (ANFH) ,and to explore indication and strategy in this surgery. Methods: From December 2006 to December 2009,37 patients (43 hips) with avascular necrosis of femoral head were treated with total hip resurfacing arthroplasty. Among the patients,25 patients were male and 12 patients were female,with an average age of 44.5 years (ranged,21 to 67 years). According to ARCO classification,3 hips were 3A stage,6 hips were 3B stage,16 hips were 3C stage and 18 hips were 4 stage. X-ray evaluation of the patients were conducted. The clinical results were evaluated by the Harris hip score system including pain,range of motion, correction of deformity and total function. Results: Thirty-four patients (40 hips) were followed up with an average period of 32.4 months (ranged, 16 to 53 months), and 3 patients were lost. Thirty-seven hips got complete relief of joint pain and 3 patients feel aching pain after walking. There was 1 heterotopic ossification, no femoral neck fracture,no dislocation,no infection and no revision in all patients. From pre-operation to present,the average Harris hip score improved significantly from (51.5±1.7) to (94.3±1.4). Thirty-seven hips got an excellent result,3 hips good and no poor. Conclusion:The total hip resurfacing arthroplasty is an effective solution for the problems of the younger and active patients with ANFH, and the short-term results are satisfying.%目的:研究全髋表面置换术治疗股骨头坏死的短期疗效,探讨表面置换术治疗股骨头坏死技术要求和手术指征.方法:对2006年12月至2009年12月37例(43髋)行全髋表面置换术的股骨头缺血坏死患者进行随访,男25例,女12例;年龄21~67岁,平均44.5岁.按照ARCO进行分期:3A期3髋,3B期6髋,3C期16髋,4期18髋.根据Harris评分系统对手术前后关节疼痛、活动度、畸形矫正

  15. Revision of Failed Hip Resurfacing and Large Metal-on-Metal Total Hip Arthroplasty Using Dual-Mobility Components.

    Science.gov (United States)

    Snir, Nimrod; Park, Brian K; Garofolo, Garret; Marwin, Scott E

    2015-06-01

    Revision of metal-on-metal (MoM) total hip arthroplasty (THA) or hip resurfacing is associated with high complication rates. The authors propose dual-mobility components as a surgical option and present short- to mid-term results of MoM hips revised with dual-mobility components. Eighteen consecutive hips that underwent revision of MoM THA or hip resurfacing using dual-mobility components were identified. At final follow-up (mean, 17.5 months), the visual analog scale, modified Harris Hip Score, and SF-12 scores had all improved (Phip resurfacing using a dual-mobility device is an effective strategy.

  16. Radiographic and clinical analysis of cementless acetabular fixation in total hip arthroplasty

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hui; PEI Fu-xing; YANG Jing; SHEN Bin; SHI Rui

    2005-01-01

    Objective: To investigate the factors affecting the fixation, loosening and therapeutic effect of cementless acetabular prosthesis through following up the patients with total hip arthroplasty clinically and radiographically.Methods: From February 1998 to May 1999, 139 patients (148 hips) underwent total hip arthroplasty with cementless acetabular prosthesis in our department. In this study, the clinical therapeutic effect and the anteroposterior radiographs of the pelvis and anteroposterior and lateral radiographs of the hips of 109 patients (116 hips) made before operation, at 1 week, 3, 6, and 12 months after operation and annually thereafter were analyzed retrospectively. The clinical therapeutic effects were evaluated with Harris hip score. Radiographs were used to observe the position of prostheses and the bone changes around the implant, and to measure the wearing speed and direction of the acetabular cup. All evaluations were made by an independent examiner who did not participate in the operation. The patients were followed up for 5-6 years.Results: The mean Harris score was 44 points (range, 10-70 points) before operation, but it increased to 92.4 points (range, 80-100 points) at the latest review after operation, which was significantly higher than that before operation (P<0.05). No acetabular component was revised because of infection or aseptic loosening. And no acetabular component migrated. There was no revision of fixed acetabular component because of pelvic osteolysis secondary to polyethylene wear. The mean linear wear rate was 0.15 mm per year. All the acetabular prostheses were classified as stable on the radiographs.Conclusions: In terms of fixation, total hip arthroplasty with cementless acetabular components was successful. Although there is no aseptic loosening and a low incidence of osteolysis at the latest follow-up evaluation, polyethylene wear cannot be avoided and can lead to expansile osteolysis near the cups. This kind of osteolysis

  17. Implant survival of the most common cemented total hip devices from the Nordic Arthroplasty Register Association database

    DEFF Research Database (Denmark)

    Junnila, Mika; Laaksonen, Inari; Eskelinen, Antti

    2016-01-01

    Background and purpose - According to previous Nordic Arthroplasty Register Association (NARA) data, the 10-year implant survival of cemented total hip arthroplasties (THAs) is 94% in patients aged 65-74 and 96% in patients aged 75 or more. Here we report a brand-level comparison of cemented THA...... based on the NARA database, which has not been done previously. Patients and methods - We determined the rate of implant survival of the 9 most common cemented THAs in the NARA database. We used Kaplan-Meier analysis with 95% CI to study implant survival at 10 and 15 years, and Cox multiple regression...

  18. Ability of lower teardrop edge to restore anatomical hip center height in total hip arthroplasty

    Institute of Scientific and Technical Information of China (English)

    Lu Yufeng; Cheng Liming; Guo Wanshou; Yu Qingsheng; Gao Fuqiang; Zhang Qidong; Liu Zhaohui

    2014-01-01

    Background The acetabular teardrop is often used to guide acetabular component placement in total hip arthroplasty (THA).Placing the lower acetabular component aspect at the same level as the lower teardrop edge was assumed to restore the hip center of rotation.Here we radiographically analyzed the relationship between cup center and normal contralateral acetabulum center height on unilateral THA using this placement method.Methods A total of 106 unilateral THA cases with normal contralateral acetabula were reviewed and the vertical and horizontal distances in relation to the lower acetabular teardrop edge from both hip joint centers,cup inclination,and anteversion were measured radiographically.The paired t-test was used to compare left and right hip center heights.Scatter plots and Pearson's correlation coefficients were used to evaluate differences in hip center heights,cup anteversion,inclination angles,and medialized cup center distance compared to the contralateral hip joint.Results Cup center height was significantly greater (P <0.01) than contralateral hip joint center height (93.4% in the 0-5 mm range,6.6% >5 mm).There was a weak correlation between hip center height difference and inclination (r=0.376,P <0.01) and between difference and anteversion (r=0.310,P <0.01) but no correlation between difference and outer cup diameter (r=0.184,P=0.058) or difference and medialized cup center distance (r=-0.098,P=0.318).Conclusions Although this method did not exactly replicate anatomic hip center height,the clinical significance of cup center height and anatomic hip center height differences is negligible.This acetabular component placement method has high simplicity,reliability,and stability.

  19. Bisphosphonate treatment for osteolysis in total hip arthroplasty. A report of four cases

    Science.gov (United States)

    Trevisan, Carlo; Nava, Veronica; Mattavelli, Marta; Parra, Cleber Garcia

    2013-01-01

    Summary Aseptic loosening due to wear debris is the most frequent modality of failure in total hip arthroplasty. Bisphosphonates, a class of molecules which inhibit bone resorption showed an inhibitory effects on particles-induced osteolysis in vitro and in animal models. We report the clinical, radiographic and densitometric outcome of four postmenopausal women with total hip arthroplasty affected by peri-prosthetic osteolysis treated with neridronate due to their unwillingness to be operated. After neridronate treatment, there was general improvement in pain and function: VAS decrease 13 points (15%), the Harris Hip Score increase 9 points (15%). An average number of 3.3 x-ray per patients with an average follow-up of 23 months (range 12–34) were collected and evaluated. In all the patients except one, serial radiographs didn’t show any progression of radioluciencies lines or periprosthetic osteolysis. Bone density was evaluated by Dual energy X-ray absorptiometry after an average follow-up of 21 months (range 6–46 mo): periprosthetic BMD around the whole stem and the cup increased respectively 2.4% and 7.1%. Treatment was well tolerated and no significant side effects were registered. This retrospective collection of a small group of patients suggest that bisphosphonates should be clinically useful in preventing periprosthetic wear debris mediated osteolysis and claim for dedicated clinical trials. PMID:23858314

  20. Clinical and radiographic evaluation of long-stem femoral components following revision total hip arthroplasty.

    Science.gov (United States)

    Meding, J B; Ritter, M A; Keating, E M; Faris, P M

    1994-08-01

    Fifty-four consecutive, long-stem revision hip arthroplasties were performed in 53 patients. In order to evaluate periprosthetic femoral changes, all cases utilizing cement, requiring bone-grafts for prosthetic stability, or with a follow-up period of less than 2 years were omitted. Thus, 32 long-stem revision hip arthroplasties in 32 patients were reviewed. Twenty-three Porous Coated Anatomic (Howmedica, Rutherford, NJ) and nine Bi-Metric (Biomet, Warsaw, IN) stems were implanted, with an average follow-up period of 3.6 years (range, 2-6 years). Prosthetic canal fill averaged 94% proximally and 80% distally. Intraoperative complications included three femoral shaft fractures. Harris hip scores averaged 47.8 points, before surgery and 87.6 points at the final follow-up evaluation, with 81% of patients the pain-free. Only three cases of subsidence and one case of osteolysis were noted. By 1 year, proximal osteopenia (off-load) (P = .005), bony condensation about the porous surface (spot weld) (P = .01), and pedestal formation (P = .004) were observed. The presence of distal cortical hypertrophy, (P = .02) spot weld (P = .001), and pedestal formation (P = .05) correlated significantly with off-load. Pedestal formation and distal cortical hypertrophy were commonly found together (P = .001). Despite significant periprosthetic remodeling, adequate fixation and satisfactory early clinical scores were achieved in this setting. Contrary to similar reviews using extensive bone-grafts, acceptable pain-free clinical results were obtained with these components.

  1. Inferior outcome after hip resurfacing arthroplasty than after conventional arthroplasty. Evidence from the Nordic Arthroplasty Register Association (NARA) database, 1995 to 2007

    DEFF Research Database (Denmark)

    Johanson, Per-Erik; Fenstad, Anne Marie; Furnes, Ove;

    2010-01-01

    The reported outcomes of hip resurfacing arthroplasty (HRA) vary. The frequency of this procedure in Denmark, Norway, and Sweden is low. We therefore determined the outcome of HRA in the NARA database, which is common to all 3 countries, and compared it to the outcome of conventional total hip...

  2. Significance of the Trendelenburg test in total hip arthroplasty. Influence of lateral approaches.

    Science.gov (United States)

    Pai, V S

    1996-02-01

    The effects of lateral approaches to total hip arthroplasty on abductor weakness and limp were studied in 264 patients with primary osteoarthritis. The Hardinge approach was used in 82 patients, the transtrochanteric approach in 94, and the Liverpool approach in 88. There was no difference in functional level, range of movement, and limp among three lateral approaches. There was no increase in Trendelenburg gait after the Hardinge or Liverpool approach compared with the transtrochanteric approach. It is evident that the Trendelenburg test is a useful part of clinical examination if performed and interpreted correctly.

  3. Comparison of complications in transtrochanteric and anterolateral approaches in primary total hip arthroplasty.

    LENUS (Irish Health Repository)

    Cashman, James P

    2008-11-01

    Three surgical approaches to primary total hip arthroplasty (THA) have been in use since Charnley popularized the transtrochanteric approach. This study was designed to examine the difference in morbidity between the transtrochanteric approach and the anterolateral approach in primary THA. Information on 891 patients who underwent primary THA performed by a single surgeon was collected prospectively between 1998 and 2003 using a modified SF-36 form, preoperatively, intraoperatively, and at 3 months postoperatively. The transtrochanteric group had higher morbidity and more patients who were dissatisfied with their THA. There was a greater range of motion in the anterolateral group.

  4. Arthroplasty combined with cup-plastics in the surgical treatment of congenital dislocation of the hip.

    Science.gov (United States)

    Udvarhelyi, I; Riskó, T; Kremsier, K; Böröcz, T

    1985-01-01

    The authors review the arthroplasty combined with cup-plastics in the treatment of congenital dislocation of the hip. The indications and surgical exploration are discussed in detail. Good results are reported. The complications and their solutions are also described. In the recent five years, 100 patients were operated by them. Based on their experiences, they suggest this intervention at an earlier age, too (i.e. 30 to 40 years). Moreover, they believe it to be an important possibility to provide an adequate rehabilitation for patients being still of working age.

  5. Effect of femoral offset on pain and function after total hip arthroplasty.

    Science.gov (United States)

    Cassidy, Kevin A; Noticewala, Manish S; Macaulay, William; Lee, Jonathan H; Geller, Jeffrey A

    2012-12-01

    The effects of altering patients' femoral offset (FO) during total hip arthroplasty on postoperative pain and function have not been well described. This study compared clinical outcomes as assessed by the Short Form 12 Health Survey and Western Ontario and McMaster University Osteoarthritis Index between patients who had their FOs restored to varying degrees (compared to the contralateral normal hip [CL]). We retrospectively measured postoperative FOs on standard anteroposterior pelvis radiographs and compared to the CL. Patients were categorized into one of 3 groups: decreased offset (offset (between -5 and +5 mm), and increased offset (> +5 mm). The decreased offset group exhibited Western Ontario and McMaster University Osteoarthritis Index Physical Function scores that were less than those of the normal offset and increased offset groups (72.03, 82.23, and 79.51, respectively [P = .019]). In conclusion, reducing a patients' native FO led to inferior functional outcome scores.

  6. Radiation-blocking shields to localize periarticular radiation precisely for prevention of heterotopic bone formation around uncemented total hip arthroplasties

    Energy Technology Data Exchange (ETDEWEB)

    Jasty, M.; Schutzer, S.; Tepper, J.; Willett, C.; Stracher, M.A.; Harris, W.H. (Massachusetts General Hospital (USA))

    1990-08-01

    Sixteen patients (18 hips) were treated with localized radiation therapy limited to periarticular regions surrounding the femoral neck by shielding the prosthesis and the adjacent regions to prevent heterotopic bone formation around the uncemented prosthesis. All hips received 1500 rads. Eight of these hips were irradiated after excising severe heterotopic bone, five because they developed extensive heterotopic ossification in the opposite hip, and five others because they were considered to be at high risk for developing heterotopic ossification. Only two of the 18 hips developed a small amount of heterotopic bone after localized periarticular radiation. All wounds healed primarily. No progressive radiolucencies developed at the bone-prosthesis interface. There was only one trochanteric nonunion of six trochanteric osteotomies. Localized periarticular radiation therapy with precision shielding of the prosthetic components and adjacent skeletal structures is an effective means to prevent heterotopic bone formation around cementless total hip arthroplasties. It also has the advantage of not adversely affecting the healing of the trochanteric osteotomy.

  7. Are antibiotics necessary in hip arthroplasty with asymptomatic bacteriuria? Seeding risk with/without treatment.

    Science.gov (United States)

    Cordero-Ampuero, José; González-Fernández, Enrique; Martínez-Vélez, David; Esteban, Jaime

    2013-12-01

    In patients with asymptomatic bacteriuria undergoing hip arthroplasty, the risk of prosthetic joint infection (PJI) and appropriateness of specific antibiotics are unclear. We determined (1) the prevalence of asymptomatic bacteriuria; and (2) the incidence of PJI in patients with asymptomatic bacteriuria managed with or without specific antibiotics. We conducted a prospective, randomized study of all 471 patients without urinary symptoms receiving a total hip arthroplasty (THA; n = 228; average age 68 years; 122 female) or hemiarthroplasty (HA; n = 243; average age 85 years; 170 female) between April 2009 and November 2010. No patients were catheterized in the perioperative period and all received intravenous cefazolin (allergy, vancomycin) for 48 hours postoperatively. Urinalysis was conducted on all patients; if abnormal, a urine culture was performed. Patients with bacteriuria (> 100,000 colonies/mL cultured) were randomly assigned to receive specific antibiotics (Group A) or not (Group B). Minimum followup was 1 month including those six who died or were lost to followup (average, 10.4 months; range, 1-12 months). Asymptomatic bacteriuria occurred in eight of 228 patients undergoing THAs (three of eight with specific antibiotics) and 38 of 243 patients undergoing HAs (23 of 38 with specific antibiotics). Arthroplasty infection after 3 months occurred in one of 228 patients undergoing THAs and 12 of 243 patients undergoing HAs (six of 117 in Group A and six of 126 in Group B); bacteria cultured from the wound were dissimilar to those cultured in urine samples in any case. No patient presented signs of PJI by 1 year after the index surgery. We identified no case of PJI from urinary origin in patients with asymptomatic bacteriuria whether or not they had been treated with specific antibiotics.

  8. Avaliação da função hepática em pacientes submetidos à artroplastia total do quadril em uso de enoxaparina Evaluation of hepatic function in patients undergoing total hip arthroplasty using enoxaparin

    Directory of Open Access Journals (Sweden)

    Felipe Vitiello Wink

    2010-01-01

    Full Text Available OBJETIVO: Avaliar as alterações hepáticas decorrentes do uso de enoxaparina para profilaxia da trombose venosa profunda em pacientes submetidos à artroplastia total do quadril. MÉTODOS: Trinta e dois pacientes submetidos à artroplastia total do quadril, em caráter eletivo, utilizando enoxaparina, foram acompanhados por 65 dias com dosagens seriadas das enzimas hepáticas. RESULTADOS: Foram encontradas alterações laboratoriais em até 75% dos pacientes durante o estudo, que normalizaram após a suspensão do tratamento. Não houve manifestação clínica de lesão hepática. CONCLUSÃO: As enzimas hepáticas elevam-se na maioria dos pacientes em uso de enoxaparina, sem correlação clínica, e normalizam após a suspensão do tratamento.OBJECTIVE: To evaluate hepatic changes due to the use of enoxaparin for prophylaxis of deep vein thrombosis in patients submitted to total hip arthroplasty. METHODS: Thirty two patients submitted to elective total hip arthroplasty, using enoxaparin, were followed up for 65 days with serial doses of hepatic enzymes. RESULTS: Laboratory changes were found in up to 75% of patients during the study, which normalized after suspension of the treatment. No clinical evidence of hepatic lesion was found. CONCLUSION: Increase in hepatic enzymes levels occurs in most patients using enoxaparin, but without clinical relevance, and normalizes after suspension of the treatment.

  9. Thigh and knee circumference, knee-extension strength, and functional performance after fast-track total hip arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Kristensen, Morten Tange; Husted, Henrik;

    2011-01-01

    OBJECTIVE: To (1) quantify changes in knee-extension strength and functional-performance at discharge after fast-track total hip arthroplasty (THA) and (2) investigate whether these changes correlate to changes in thigh and knee circumference (ie, swelling) or pain. DESIGN: A prospective......, descriptive, hypothesis-generating study. SETTING: A special unit for fast-track hip and knee arthroplasty operations at a university hospital. PARTICIPANTS: Twenty-four patients (20 women and 4 men; ages 69 ± 6.1 years) scheduled for primary unilateral THA. METHODS: All patients were evaluated before surgery...... and on the day of hospital discharge. MAIN OUTCOME MEASURES: Knee-extension strength, thigh and knee joint circumference, hip pain, and functional performance (Timed Up & Go, 30-Second Chair Stand, and 10-Meter Walk tests). RESULTS: All investigated variables changed significantly from before to after surgery...

  10. Long-term clinical outcomes following the use of synthetic hydroxyapatite and bone graft in impaction in revision hip arthroplasty.

    Science.gov (United States)

    Aulakh, Tajeshwar S; Jayasekera, Narlaka; Kuiper, Jan-Herman; Richardson, James B

    2009-03-01

    Impaction grafting using morsellised allograft bone restores bone stock, but carries the potential for transmission of infection. Synthetic bone graft substitutes can eliminate this risk but may, however, influence outcome. In this study we tested the hypothesis that a 50/50 mix of hydroxyapatite and allograft does not affect long-term function, survival or radiological outcome. Sixty-five patients had revision hip arthroplasty using impaction grafting with either pure allograft (42 patients) or a 50/50 mixture of allograft and solid particulate hydroxyapatite. Harris hip scores were assessed pre-operatively and annual intervals thereafter. Function was analyzed using multilevel modeling, the Kaplan-Meier method used for survival analysis and graft incorporation was assessed radiologically. The hip score improved in both groups but showed a small annual decline (average 1.2/year, plong-term prosthesis survival and function following revision arthroplasty with a 50/50 mixture of allograft and hydroxyapatite are comparable to allograft alone.

  11. Post-operative blood salvage and retransfusion in total hip and knee arthroplasty.

    Science.gov (United States)

    Athanasoulias, V; Mavrogenis, A F; Sdrenias, C V; Mitsiokapa, E A; Lourikas, V; Papagelopoulos, P J; Christodoulou, N A

    2007-01-01

    This retrospective study evaluated the safety and efficacy of post-operative blood salvage and retransfusion in 430 patients undergoing total hip arthroplasty and 530 patients undergoing total knee arthroplasty. Volumes of autologous blood retransfused (mean +/- SD) were 525 +/- 75 and 660 +/- 95 ml in the hip and knee replacement groups, respectively. Overall, 230 patients (24%) also required allogeneic blood transfusion. In a subgroup of 150 randomly selected patients, the values of free haemoglobin in the allogeneic, autologous and patients' blood at the time of surgery were 0.568 +/- 0.112, 0.272 +/- 0.067 and 0.032 +/- 0.011 g/l, respectively. On the first and third post-operative days, the levels in patients' blood were 0.092 +/- 0.039 and 0.057 +/- 0.028 g/l, respectively. There were no major complications; transient chills and fever were reported in 99 (10.3%) and 115 patients (12.0%), respectively. In conclusion, post-operative blood salvage and retransfusion is a safe way to reduce the need for allogeneic blood transfusion in patients undergoing elective orthopaedic surgery.

  12. Late Nontraumatic Dissociation of the Femoral Head and Trunnion in a Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Simon J. M. Parker

    2015-01-01

    Full Text Available Background. Modular total hip arthroplasties are increasingly popular because customisation allows optimal restoration of patient biomechanics. However, the introduction of component interfaces provides greater opportunities for failure. We present a case of late nontraumatic dissociation of the head-neck interface, more than 10 years after insertion. Case Description. A 58-year-old woman had a left metal-on-metal total hip arthroplasty in 2002 for hip dysplasia. Following an uneventful 10-year period, she presented to hospital in severe pain after standing from a seated position, and radiographs demonstrated complete dissociation of the modular femoral head from the stem, with the femoral head remaining in its cup. There was no prior trauma or infection. Mild wear and metallosis were present on the articulating surface between the femoral head and trunnion. Soft tissues were unaffected. Discussion and Conclusions. This is the latest occurrence reported to date for nontraumatic component failure in such an implant by more than 7 years. The majority of cases occur in the context of dislocation and attempted closed reduction. We analyse and discuss possible mechanisms for failure, aiming to raise awareness of this potential complication and encouraging utmost care in component handling and insertion, as well as the long term follow-up of such patients.

  13. 4-dimensional computer-based motion simulation after Total Hip Arthroplasty.

    Science.gov (United States)

    Otake, Yoshito; Hagio, Keisuke; Suzuki, Naoki; Hattori, Asaki; Sugano, Nobuhiko; Yonenobu, Kazuo; Ochi, Takahiro

    2003-01-01

    This paper represents a novel 4-dimensional(4D) computer-based motion simulation system for patients having had Total Hip Arthroplasty(THA). By constructing the skeletal model of the patient's lower extremity and measuring daily motions, we simulated the movement of the inner structures including the skeleton and the artificial joint. This system visually represents not only the 3-dimensional(3D) anatomical structure but also the 4-dimensional dynamic functions that represent the time sequential transitions of the position of each component. Clinicians can get detailed information of the movement of the hip joint quantitatively and give precise guidance for the patients with regard to postoperative daily motions. The measurement error was evaluated by performing experiments using OpenMRI and the results indicated sufficient accuracy of this system. We believe that this system enables clinicians to reveal the causes of complications after THA and encourages the development of new surgical techniques, materials. and designs of prostheses.

  14. Bilateral Total Hip Arthroplasty in Femoral Head Avascular Necrosis: Functional Outcomes and Complications

    Directory of Open Access Journals (Sweden)

    Afshin Taheriazam

    2016-06-01

    Full Text Available Total hip arthroplasty (THA is one of the successful and cost-benefit surgical treatments. One-stage bilateral THA (BTHA offers many benefits. However, there are concerns about the safety of the procedure and higher complications. We aimed to evaluate the complications and outcomes of one-stage BTHA with Hardinge approach for femoral head avascular necrosis patients. A total of 60 patients from April 2009 and May 2013, were underwent one-stage bilateral total hip arthroplasty (BTHA in Milad and Erfan hospitals, Tehran, Iran. A prospective analysis of the functional outcomes and complications of one-stage BTHA through Hardinge approach in patients with femoral head avascular necrosis (AVN performed. We evaluated all patients clinically and radiologically with serial follow-ups. A clinical hip score based upon the modified Harris Hip Score (MHHS was performed preoperatively and again postoperatively. During period of study 44 men (73.3% and 16 women (26.6% with a mean age of 31.40±4.08 years (range 25 to 36 years at the time of presentation were entered. The mean surgical time was 2.6±0.38 hrs. The mean hospital stay was 3 .50±0.72 days. Hemoglobin level decreased significa ntly after operation (P= 0.046. There was no reported patient with perioperative death, deep venous thrombosis, pulmonary embolism, infection, dislocation, periprosthetic fracture or heterotrophic ossification. The mean preoperative MHHS score was 47.93±7.33 in patients. MHHS score i mproved to 95.06±3.47 in the last follow-up (P=0.0001.Our results recommend the use of one-stage BTHA through Hardinge approach in femoral head avascular necrosis patients.

  15. Favorable outcome of a total hip arthroplasty with insufficient bone coverage of the roof reinforcement ring

    Directory of Open Access Journals (Sweden)

    Fernando M. Judas

    2015-01-01

    Conclusion: This result can be supported by the good fixation of the metal ring to the pelvis with screws, the adequate orientation of both components of the total hip arthroplasty, and the bone graft incorporation.

  16. Intraoperative fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem.

    Science.gov (United States)

    Meek, R M Dominic; Garbuz, Donald S; Masri, Bassam A; Greidanus, Nelson V; Duncan, Clive P

    2004-03-01

    In revision total hip arthroplasty, intraoperative split fractures and cortical perforation fractures are becoming a more common concern with the increasing use of diaphyseal fitting cementless stems. The purpose of this study was to evaluate the risk factors and frequency of intraoperative fractures with the use of these stems and their effect on radiographic and functional outcomes. We performed a retrospective case-control study of 211 consecutive patients who had undergone revision hip arthroplasty with a diaphyseal fitting cementless stem between December 1998 and March 2002. Sixty-four patients sustained an intraoperative fracture of the femur. One hundred and fifteen patients were followed for a minimum of two years; function was analyzed with self-administered outcome questionnaires, and radiographs were evaluated for evidence of bone ingrowth into the femoral stem. Risk factors associated with an intraoperative fracture were a substantial degree of preoperative bone loss, a low femoral cortex-to-canal ratio, underreaming of the cortex, and the use of a large-diameter stem. The majority of the diaphyseal undisplaced linear fractures occurred at the distal end of an extended trochanteric osteotomy during stem insertion. Fracture due to cortical perforation occurred most often during cement removal. These intraoperative fractures had no significant effect on the functional outcome or radiographic evidence of bone ingrowth. There was a surprisingly high rate of intraoperative femoral fractures associated with the use of a diaphyseal fitting stem in revision total hip arthroplasty. Identification of risk factors such as preoperative bone loss and a low cortex-to-canal ratio may permit planning to avoid such fractures. However, the final functional and radiographic outcomes appear to have been unaffected by the fracture when it had been managed appropriately. Prognostic study, Level II-1 (retrospective cohort study). See Instructions to Authors for a complete

  17. Arthroplasty using a custom-made cemented total hip prosthesis for an extensive giant cell tumor of the proximal femur: report of a patient followed up for over 30 years.

    Science.gov (United States)

    Nakano, Shunji; Enishi, Tetsuya; Hasan, Mohamed Yehya; Hanaoka, Naoyoshi; Kawasaki, Yoshiteru; Egawa, Hiroshi; Kinoshita, Isamu; Yasui, Natsuo

    2009-09-01

    We report the case of a 26-year-old man who had a pathologic transtrochanteric fracture of the left femur due to a grade II giant cell tumor affecting the neck and the trochanteric area. This patient underwent complete resection of the tumor and arthroplasty using a custom-made cemented total hip prosthesis. The good radiologic and functional results of the surgery have been maintained for over 30 years without local recurrence or lung metastasis. Moreover, new bone formation was observed at the reattachment sites of abductors, iliopsoas tendons and vastus lateralis to the femoral component of the prosthesis although local bone resorption was detected at the upper lateral part of the femoral stem and zone I of the cup side.

  18. Prevention of post-operative anaemia in hip and knee arthroplasty - a systematic review

    DEFF Research Database (Denmark)

    Khan, Nissa; Troelsen, Anders; Husted, Henrik

    2015-01-01

    and minimised the length of stay. A similar result was found for fibrin spray in total hip arthroplasty. However, for total knee arthroplasty, the outcome was blurred. Tourniquet use was uniformly not significant in the measured parameters. CONCLUSIONS: Tranexamic acid is useful in managing anaemia and blood...

  19. Low Risk of Thromboembolic Events After Routine Administration of Tranexamic Acid in Hip and Knee Arthroplasty

    DEFF Research Database (Denmark)

    Madsen, Rune V; Nielsen, Christian S; Kallemose, Thomas;

    2016-01-01

    BACKGROUND: The blood-conserving effect of intravenous (IV) tranexamic acid (TXA) is well-documented for total hip arthroplasty (THA) and total knee arthroplasty (TKA). However, the risk of thromboembolic (TE) events after routine use of TXA is unclear and the safety profile is debated. This retr...

  20. Low risk of thromboembolic complications after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B;

    2010-01-01

    Pharmacological prophylaxis can reduce the risk of deep venous thrombosis (DVT), pulmonary embolism (PE), and death, and it is recommended 10–35 days after total hip arthroplasty (THA) and at least 10 days after total knee arthroplasty (TKA). However, early mobilization might also reduce the risk...

  1. Early results of large head metal-on-metal hip arthroplasties.

    Science.gov (United States)

    Kostensalo, I; Seppänen, M; Mäkelä, K; Mokka, J; Virolainen, P; Hirviniemi, J

    2012-01-01

    Total hip arthroplasty significantly improves patient's life quality. However, total joint replacement is associated with possible complications, such as dislocations, infections, fractures and periprosthetic osteolysis. The goal of this study was to evaluate a large head metal-on-metal total hip arthroplasties and analyse short term complications related to them. Between 9/2005 and 6/2009, a total of 691 hip replacements were performed on 635 patients with the use of Magnum M2 large head cementless metal-on-metal prosthesis in Turku University Hospital. All patients had a scheduled follow-up at two to three months, and at one year. The results were evaluated using X-rays, Harris Hip Score (HHS), and evaluating post-operative complications and reasons for re-operations. During our follow-up the HHS median raised from its preoperative value of 59.8 to 86.4 two to three months after the operation, and to 93.9 one year after the operation. As a complication we had five infections requiring single open debridement (early infection) or a two stage revision. Seven patients had a periprosthetic femoral fracture that was operated and 11 patients were reoperated because of acetabular component malposition, fracture or early loosening. We did not observe any dislocations, n. ischiadicus damages, squeeking or complications related to high metal ion release (ALVAL-reactions (Aseptic Lymphocyte-dominated Vasculitis-Associated Lesion) or pseudotumours). The metal-on-metal bearing pair allows large femoral head size, which decreases the risk for dislocation. It may also decrease the risk for osteolysis and aseptic loosening in a long run. Early complication rate related to the bearing surface is minimal. Metal-on-metal prosthesis is a good choice for young and active patients with good bone quality.

  2. Botulinum toxin type A injections for the management of muscle tightness following total hip arthroplasty: a case series

    Directory of Open Access Journals (Sweden)

    Delanois Ronald E

    2009-08-01

    Full Text Available Abstract Background Development of hip adductor, tensor fascia lata, and rectus femoris muscle contractures following total hip arthroplasties are quite common, with some patients failing to improve despite treatment with a variety of non-operative modalities. The purpose of the present study was to describe the use of and patient outcomes of botulinum toxin injections as an adjunctive treatment for muscle tightness following total hip arthroplasty. Methods Ten patients (14 hips who had hip adductor, abductor, and/or flexor muscle contractures following total arthroplasty and had been refractory to physical therapeutic efforts were treated with injection of botulinum toxin A. Eight limbs received injections into the adductor muscle, 8 limbs received injections into the tensor fascia lata muscle, and 2 limbs received injection into the rectus femoris muscle, followed by intensive physical therapy for 6 weeks. Results At a mean final follow-up of 20 months, all 14 hips had increased range in the affected arc of motion, with a mean improvement of 23 degrees (range, 10 to 45 degrees. Additionally all hips had an improvement in hip scores, with a significant increase in mean score from 74 points (range, 57 to 91 points prior to injection to a mean of 96 points (range, 93 to 98 at final follow-up. There were no serious treatment-related adverse events. Conclusion Botulinum toxin A injections combined with intensive physical therapy may be considered as a potential treatment modality, especially in difficult cases of muscle tightness that are refractory to standard therapy.

  3. Femoral lengthening during hip resurfacing arthroplasty: a new surgical procedure.

    Science.gov (United States)

    Vasseur, L; Ayoub, B; Mesnil, P; Pasquier, G; Migaud, H; Girard, J

    2015-04-01

    Correction of leg length discrepancy during hip arthroplasty is a technical challenge. Although resurfacing proposed to young subjects presents a number of advantages (stability, bone stock, etc.), it does not correct leg length discrepancy. We propose an original femoral lengthening technique concomitant to resurfacing performed through the same approach, consisting in a Z-shaped subtrochanteric osteotomy. Resurfacing was performed first and the femoral and acetabular reaming material was used for autografting. The series comprised five cases followed for a mean 42.2 months (range, 33-64 months). The mean surgical time was 100 min (range, 76-124 min). Weightbearing was authorized in all cases at the 8th week. The mean lengthening was 32 mm (range, 25-40 mm). Healing was observed in all cases. This surgical technique, reserved for very young subjects who accept an 8-week postoperative period without weightbearing, can be proposed in cases with substantial preoperative leg length discrepancy.

  4. Return to sporting activity after Birmingham hip resurfacing arthroplasty: Mid term results

    Directory of Open Access Journals (Sweden)

    Nemandra Sandiford

    2015-01-01

    Full Text Available Background: Hip resurfacing arthroplasty (HRA is primarily indicated for young, active patients with disabling coxarthrosis who wish to remain active and return to sports after surgery. Relatively few prospective studies have assessed return to sporting activity and impact of gender and age on this. Materials and Methods: Seventy-nine consecutive patients treated with HRA were included. Patients were reviewed clinically and radiologically. Function was assessed using the modified University of California Los Angeles (UCLA activity score. The Oxford, Harris and WOMAC hip scores were calculated. Results: Average age at the time of surgery was 54.9 years (range 34.5–73.6 years. Average preoperative and postoperative UCLA scores were 4 and 7.6 respectively. Patients were involved in 2 (0–4 sporting activities preoperatively and 2 (0–5 postoperatively. Preoperative and postoperative Oxford Hip Scores, Harris Hip Score and WOMAC scores were 40, 46 and 51 and 16, 94 and 3 respectively (P < 0.0001. Patients returned to sports at an average of 3 months postoperatively. Conclusion: Patients were able to return to sports by 3 months and perform the same number of activities at preoperative intensity. Activity levels are maintained up to the medium term with few complications.

  5. People who undergo revision arthroplasty report more limitations but no decrease in physical activity compared with primary total hip arthroplasty : an observational study

    NARCIS (Netherlands)

    Stevens, Martin; Hoekstra, Tsjerk; Wagenmakers, Robert; Bulstra, Sjoerd K.; van den Akker-Scheek, Inge

    2009-01-01

    Question: Do people who have had revision arthroplasty report more limitations and less physical activity than those after primary total hip arthroplasty? Can degree of limitation and physical activity be predicted by revision arthroplasty, after adjustment for age, gender, and Charnley classificati

  6. Rehabilitation and prevention of complications after total hip arthroplasty

    OpenAIRE

    Ruzibaev Dilmurod Ruzimetovic; Asilova Saodat Ubaevna; Nurimov Gayrat Kadamboyevich

    2015-01-01

    A comparative analysis of the structure and frequency of complications after total hip replacement (THR) and basic methods of prevention based on experience treating 303 patients with diseases and injuries of the hip joint. It is proved that a comprehensive system of rehabilitation of patients, which includes preoperative preparation, prevention of complications, operation planning and original methods of treatment, diagnostics and physiotherapy, for each stage of treatment, up...

  7. Effects of hip joint center location and femoral offset on abductor muscle strength after total hip arthroplasty.

    Science.gov (United States)

    Tezuka, Taro; Inaba, Yutaka; Kobayashi, Naomi; Ike, Hiroyuki; Kubota, So; Kawamura, Masaki; Saito, Tomoyuki

    2015-07-01

    The purposes of this study were 1) to examine the changes in the hip joint center (HJC) position and the femoral offset (FO) after total hip arthroplasty (THA) and 2) to investigate the effects of the HJC and FO on isometric abductor muscle strength. We evaluated 51 patients who underwent unilateral primary THA. The FO, and horizontal and vertical distances from the HJC to the tip of the teardrop were measured and isometric hip abductor muscle strength was measured. The HJC of the affected side moved medially postoperatively compared with that of the unaffected side (p < 0.05), and the FO was reconstructed similarly to the unaffected side. There were significant negative correlations between the changes in the horizontal distance from the HJC and FO to the tip of the teardrop. An increase in the FO and infero-medial cup position optimized hip abductor muscle strength. The HJC was reconstructed medially and superiorly, and the change in the FO after THA was influenced by the change in the horizontal distance of the HJC. Multiple regression analysis revealed that the medial and inferior HJC and increase in the FO constitute an effective procedure for restoring abductor strength.

  8. Trochanteric bursitis after total hip arthroplasty: incidence and evaluation of response to treatment.

    Science.gov (United States)

    Farmer, Kevin W; Jones, Lynne C; Brownson, Kirstyn E; Khanuja, Harpal S; Hungerford, Marc W

    2010-02-01

    We examined the efficacy of corticosteroid injection as treatment for postarthroplasty trochanteric bursitis and the risk factors for failure of nonoperative treatment. There were 32 (4.6%) cases of postsurgical trochanteric bursitis in 689 primary total hip arthroplasties. Of the 25 hips with follow-up, 11 (45%) required multiple injections. Symptoms resolved in 20 (80%) but persisted in 5. We found no statistically significant differences between patients who did and did not develop trochanteric bursitis, or between those who did and did not respond to treatment. There was a trend toward younger age and greater limb-length discrepancy in nonresponders. In conclusion, (1) corticosteroid injection(s) for postoperative trochanteric bursitis is effective; and (2) nonoperative management may be more likely to fail in young patients and those with leg-length discrepancy. 2010 Elsevier Inc. All rights reserved.

  9. Current status of modern fully porous coated metal-on-metal hip resurfacing arthroplasty.

    Science.gov (United States)

    Gross, Thomas P; Liu, Fei

    2014-01-01

    Between March 2007 and July 2010, 1000 consecutive fully porous coated hip resurfacing arthroplasties (HRA) were performed by a single surgeon in 871 patients. The average length of follow-up was 3 ± 1 years. Three cases (0.3%) in three patients showed adverse wear related failures. Another 17 (1.7%) failures were identified at the time of this study. Using any failure of any component as the endpoint, the survivorship rate was 98.8% at two years and 97.4% at five years. Excluding the failed cases, all components were radiographically stable; there was only one partial femoral radiolucency seen. The clinical and radiological outcomes of this fully porous coated hip resurfacing were comparable to, if not better than, those reported by others using hybrid fixation methods at five years post-operatively.

  10. Assessment of changes in gait parameters and vertical ground reaction forces after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Bhargava P

    2007-01-01

    Full Text Available The principal objectives of arthroplasty are relief of pain and enhancement of range of motion. Currently, postoperative pain and functional capacity are assessed largely on the basis of subjective evaluation scores. Because of the lack of control inherent in this method it is often difficult to interpret data presented by different observers in the critical evaluation of surgical method, new components and modes of rehabilitation. Gait analysis is a rapid, simple and reliable method to assess functional outcome. This study was undertaken in an effort to evaluate the gait characteristics of patients who underwent arthroplasty, using an Ultraflex gait analyzer. Materials and Methods: The study was based on the assessment of gait and weight-bearing pattern of both hips in patients who underwent total hip replacement and its comparison with an age and sex-matched control group. Twenty subjects of total arthroplasty group having unilateral involvement, operated by posterior approach at our institution with a minimum six-month postoperative period were selected. Control group was age and sex-matched, randomly selected from the general population. Gait analysis was done using Ultraflex gait analyzer. Gait parameters and vertical ground reaction forces assessment was done by measuring the gait cycle properties, step time parameters and VGRF variables. Data of affected limb was compared with unaffected limb as well as control group to assess the weight-bearing pattern. Statistical analysis was done by′t′ test. Results: Frequency is reduced and gait cycle duration increased in total arthroplasty group as compared with control. Step time parameters including Step time, Stance time and Single support time are significantly reduced ( P value < .05 while Double support time and Single swing time are significantly increased ( P value < .05 in the THR group. Forces over each sensor are increased more on the unaffected limb of the THR group as compared to

  11. Anterior Inferior Iliac Spine Bone Morphology in Hip Dysplasia and Its Effect on Hip Range of Motion in Total Hip Arthroplasty.

    Science.gov (United States)

    Shoji, Takeshi; Yasunaga, Yuji; Yamasaki, Takuma; Izumi, Soutarou; Adachi, Nobuo; Ochi, Mitsuo

    2016-09-01

    Despite the fact that femoral impingement against the anterior inferior iliac spine (AIIS) is increasingly recognized, there is no description of morphologic features of the AIIS in hip dysplasia and their effect on hip range of motion (ROM) in total hip arthroplasty (THA). The purpose is to evaluate the bone morphology of the AIIS in hip dysplasia and whether its morphology affects hip ROM in THA. Computed tomography-based simulation software was used to create 3-dimensional bone models and perform virtual simulations. Using the computed tomographic data of 85 patients (male: n = 25, female: n = 60, mean age: 60.9) with hip osteoarthritis due to dysplasia, we measured the straight, vertical, and horizontal distances between the anteroinferior edge of the AIIS and the center of rotation in sagittal and axial views. The anterior and lateral versions of the AIIS were also measured. We calculated the ROM of flexion (Flex), and internal rotation (Int-R) in THA in the software, and analyzed the correlations among them. The AIIS prominence is bigger and extends more anteriorly and laterally in males than in females. Furthermore, the taller the patient, the more the AIIS extends anteriorly and laterally. We found that Flex and Int-R decreased inversely proportional to the size and lateral version of the AIIS. Our results demonstrated that the AIIS bone morphology substantially affects the ROM of Flex and Int-R especially in patients with laterally large AIIS bony anatomy in THA. Furthermore, our result indicates that the morphologic features of AIIS in hip dysplasia may be different between males and females. Copyright © 2016 Elsevier Inc. All rights reserv