WorldWideScience

Sample records for highly sensitive electrochemiluminescence

  1. An improved electrochemiluminescence polymerase chain reaction method for highly sensitive detection of plant viruses

    International Nuclear Information System (INIS)

    Tang Yabing; Xing Da; Zhu Debin; Liu Jinfeng

    2007-01-01

    Recently, we have reported an electrochemiluminescence polymerase chain reaction (ECL-PCR) method for detection of genetically modified organisms. The ECL-PCR method was further improved in the current study by introducing a multi-purpose nucleic acid sequence that was specific to the tris(bipyridine) ruthenium (TBR) labeled probe, into the 5' terminal of the primers. The method was applied to detect plant viruses. Conserved sequence of the plant viruses was amplified by PCR. The product was hybridized with a biotin labeled probe and a TBR labeled probe. The hybridization product was separated by streptavidin-coated magnetic beads, and detected by measuring the ECL signals of the TBR labeled. Under the optimized conditions, the experiment results show that the detection limit is 50 fmol of PCR products, and the signal-to-noise ratio is in excess of 14.6. The method was used to detect banana streak virus, banana bunchy top virus, and papaya leaf curl virus. The experiment results show that this method could reliably identity viruses infected plant samples. The improved ECL-PCR approach has higher sensitivity and lower cost than previous approach. It can effectively detect the plant viruses with simplicity, stability, and high sensitivity

  2. Luminol-based electrochemiluminescent biosensors for highly sensitive medical diagnosis and rapid antioxidant detection

    Science.gov (United States)

    Tamiya, Eiichi; Inoue, Yuki; Saito, Masato

    2018-03-01

    We present a review of luminol-based electrochemiluminescence (ECL) biosensors that perform enzymatic reactions and bioanalysis using antioxidant molecules by controlling the spatiotemporal production of a luminescent substrate, catalase activity, and glycated albumin (GA). The ECL intensity depends on the antioxidant capacity because radicals are neutralized by the antioxidants, which suppresses the luminescence. The antioxidant capacities of 22 types beverages were evaluated by comparison with a standard curve of Trolox. The time necessary for the ECL measurement of the antioxidant capacity is only 2 min with screen-printed electrodes and a portable ECL measurement system. Our system was also used to monitor reactive oxygen species released from neutrophils, which play an important role in the immune system, defending against viral and bacterial infections. The quenching of ECL imaging by catalase reaction localized in the multichamber electrode using the electrogenerated substrate was examined as a potential candidate for a sensitive reporting system. The substrate was successfully generated at applied potentials between -1 and -0.4 V in multichamber electrodes and the substrate confinement within the chamber was observed within 60 s of generation. The microchamber electrode system demonstrated a detection limit of 90 fM catalase. We also demonstrated a detection limit of 0.1 µM GA in human serum albumin, which is an improvement of about 70 times over colorimetric methods.

  3. Highly sensitive "signal-on" electrochemiluminescent biosensor for the detection of DNA based on dual quenching and strand displacement reaction.

    Science.gov (United States)

    Lou, Jing; Wang, Zhaoyin; Wang, Xiao; Bao, Jianchun; Tu, Wenwen; Dai, Zhihui

    2015-10-07

    A "signal-on" electrochemiluminescent DNA biosensing platform was proposed based on the dual quenching and strand displacement reaction. This novel "signal-on" detection strategy revealed its sensitivity in achieving a detection limit of 2.4 aM and its selectivity in distinguishing single nucleotide polymorphism of target DNA.

  4. Capillary electrophoresis with electrochemiluminescent detection for highly sensitive assay of genetically modified organisms.

    Science.gov (United States)

    Guo, Longhua; Yang, Huanghao; Qiu, Bin; Xiao, Xueyang; Xue, Linlin; Kim, Donghwan; Chen, Guonan

    2009-12-01

    A capillary electrophoresis coupled with electrochemiluminescent detection system (CE-ECL) was developed for the detection of polymerase chain reaction (PCR) amplicons. The ECL luminophore, tris(1,10-phenanthroline) ruthenium(II) (Ru(phen)(3)(2+)), was labeled to the PCR primers before amplification. Ru(phen)(3)(2+) was then introduced to PCR amplicons by PCR amplification. Eventually, the PCR amplicons were separated and detected by the homemade CE-ECL system. The detection of a typical genetically modified organism (GMO), Roundup Ready Soy (RRS), was shown as an example to demonstrate the reliability of the proposed approach. Four pairs of primers were amplified by multiple PCR (MPCR) simultaneously, three of which were targeted on the specific sequence of exogenous genes of RRS, and another was targeted on the endogenous reference gene of soybean. Both the conditions for PCR amplification and CE-ECL separation and detection were investigated in detail. Results showed that, under the optimal conditions, the proposed method can accurately identifying RRS. The corresponding limit of detection (LOD) was below 0.01% with 35 PCR cycles.

  5. Polyelectrolyte-based electrochemiluminescence enhancement for Ru(bpy){sub 3}{sup 2+} loaded by SiO{sub 2} nanoparticle carrier and its high sensitive immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Zhi-Li; Song, Tian-Mei; Chen, Zhe [College of Pharmaceutical Science, Soochow University, Suzhou 215123 (China); Guo, Wu-Run [College of Pharmaceutical Science, Soochow University, Suzhou 215123 (China); College of Chemistry and Chemical Engineering, China West Normal University, Nanchong 637002 (China); Xie, Hong-Ping, E-mail: hpxie@suda.edu.cn [College of Pharmaceutical Science, Soochow University, Suzhou 215123 (China); Xie, Lian, E-mail: xielian@suda.edu.cn [College of Pharmaceutical Science, Soochow University, Suzhou 215123 (China)

    2015-03-03

    Highlights: • Preparation of strong ECL nanoparticles PAA–Ru@SiO{sub 2}/[PAA⋯Ru&Nafion⋯Ru]. • Ion-pair macromolecule PAA–Ru formed to greatly increase the doping amount. • PAA&Nafion membrane increased the amount of ion-exchanged Ru(bpy){sub 3}{sup 2+}. • PAA&Nafion membrane enhanced the ability of electron transfer. • Realized antibody labeling and established a high-sensitive immunoassay. - Abstract: In this paper the strong electrochemiluminescence (ECL) nanoparticles have been prepared based on the anionic polyelectrolyte sodium polyacrylate (PAA)-ECL enhancement for Ru(bpy){sub 3}{sup 2+}, which were loaded by the carrier of SiO{sub 2} nanoparticle. There were two kinds of Ru(bpy){sub 3}{sup 2+} for the as-prepared nanoparticles, the doped one and the exchanged one. The former was loaded inside the ECL nanoparticles by doping, in a form of ion-pair macromolecules PAA–Ru(bpy){sub 3}{sup 2+}. The corresponding ECL was enhanced about 2 times owing to the doping increase of Ru(bpy){sub 3}{sup 2+}. The latter was loaded on the PAA-doped Nafion membrane by ion exchange. The corresponding ECL was enhanced about 3 times owing to the ion-exchanging increase of Ru(bpy){sub 3}{sup 2+}. At the same time, ECL intensity of the doped-inside Ru(bpy){sub 3}{sup 2+} was further enhanced 13 times because polyelectrolyte PAA in the doped membrane could obviously enhance electron transfer between the doped Ru(bpy){sub 3}{sup 2+} and the working electrode. Furthermore, based on hydrophobic regions of the doped membrane antibody labeling could be easily realized by the as-prepared nanoparticles and then a high sensitive ECL immunoassay for HBsAg was developed. The linear range was between 1.0 and 100 pg mL{sup −1} (R{sup 2} = 0.9912). The detection limit could be as low as 0.11 pg mL{sup −1} (signal-to-noise ratio = 3)

  6. A highly selective molecularly imprinted electrochemiluminescence sensor for ultra-trace beryllium detection

    International Nuclear Information System (INIS)

    Li, Jianping; Ma, Fei; Wei, Xiaoping; Fu, Cong; Pan, Hongcheng

    2015-01-01

    Graphical abstract: A novel molecular imprinted electrochemiluminescence sensor was fabricated for ultra-trace Be 2+ detection with an extremely lower detection limit based on the luminol–H 2 O 2 ECL system. - Highlights: • A novel molecular imprinted electrochemiluminescence sensor was fabricated for ultra-trace Be 2+ detection. • Imprint cavities in the MIPs from elution the Be–PAR complex could provide more recognition sites for analytes. • ECL emission produced by the luminol–H 2 O 2 ECL system, which was applied to detect Be 2+ . • It gave an extremely lower detection limit (2.35 × 10 −11 mol L −1 ) than the reported methods. - Abstract: A new molecularly imprinted electrochemiluminescence (ECL) sensor was proposed for highly sensitive and selective determination of ultratrace Be 2+ determination. The complex of Be 2+ with 4-(2-pyridylazo)-resorcinol (PAR) was chosen as the template molecule for the molecularly imprinted polymer (MIP). In this assay, the complex molecule could be eluted from the MIP, and the cavities formed could then selectively recognize the complex molecules. The cavities formed could also work as the tunnel for the transfer of probe molecules to produce sound responsive signal. The determination was based on the intensity of the signal, which was proportional to the concentrations of the complex molecule in the sample solution, and the Be 2+ concentration could then be determined indirectly. The results showed that in the range of 7 × 10 −11 mol L −1 to 8.0 × 10 −9 mol L −1 , the ECL intensity had a linear relationship with the Be 2+ concentrations, with the limit of detection of 2.35 × 10 −11 mol L −1 . This method was successfully used to detect Be 2+ in real water samples

  7. A sensitive electrochemiluminescence cytosensor for quantitative evaluation of epidermal growth factor receptor expressed on cell surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yanjuan; Zhang, Shaolian; Wen, Qingqing; Huang, Hongxing; Yang, Peihui, E-mail: typh@jnu.edu.cn

    2015-06-30

    Highlights: • EGF-cytosensor was used for evaluating EGFR expression level on cell surfaces. • CdSQDs and EGF were coated on magnetic beads (MBs) for ECL-probe. • Good sensitivity was achieved due to the signal amplification of ECL-probe. - Abstract: A sensitive electrochemiluminescence (ECL) strategy for evaluating the epidermal growth factor receptor (EGFR) expression level on cell surfaces was designed by integrating the specific recognition of EGFR expressed on MCF-7 cell surfaces with an epidermal growth factor (EGF)-funtionalized CdS quantum dots (CdSQDs)-capped magnetic bead (MB) probe. The high sensitivity of ECL probe of EGF-funtionalized CdSQD-capped-MB was used for competitive recognition with EGFR expressed on cell surfaces with recombinant EGFR protein. The changes of ECL intensity depended on both the cell number and the expression level of EGFR receptor on cell surfaces. A wide linear response to cells ranging from 80 to 4 × 10{sup 6} cells mL{sup −1} with a detection limit of 40 cells mL{sup −1} was obtained. The EGF-cytosensor was used to evaluate EGFR expression levels on MCF-7 cells, and the average number of EGFR receptor on single MCF-7 cells was 1.35 × 10{sup 5} with the relative standard deviation of 4.3%. This strategy was further used for in-situ and real-time evaluating EGFR receptor expressed on cell surfaces in response to drugs stimulation at different concentration and incubation time. The proposed method provided potential applications in the detection of receptors on cancer cells and anticancer drugs screening.

  8. Electrochemiluminescence resonance energy transfer between graphene quantum dots and graphene oxide for sensitive protein kinase activity and inhibitor sensing

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Ru-Ping; Qiu, Wei-Bin; Zhao, Hui-Fang; Xiang, Cai-Yun; Qiu, Jian-Ding, E-mail: jdqiu@ncu.edu.cn

    2016-01-21

    Herein, a novel electrochemiluminescence resonance energy transfer (ECL-RET) biosensor using graphene quantum dots (GQDs) as donor and graphene oxide (GO) as acceptor for monitoring the activity of protein kinase was presented for the first time. Anti-phosphoserine antibody conjugated graphene oxide (Ab-GO) nonocomposite could be captured onto the phosphorylated peptide/GQDs modified electrode surface through antibody–antigen interaction in the presence of casein kinase II (CK2) and adenosine 5′-triphosphate (ATP), resulting in ECL from the GQDs quenching by closely contacting GO. This ECL quenching degree was positively correlated with CK2 activity. Therefore, on the basis of ECL-RET between GQDs and GO, the activity of protein kinase can be detected sensitively. This biosensor can also be used for quantitative analysis CK2 activity in serum samples and qualitative screening kinase inhibition, indicating the potential application of the developed method in biochemical fundamental research and clinical diagnosis. - Highlights: • We reported a novel ECL-RET biosensor for sensitive analysis of casein kinase II activity. • The successful ECL-RET between GQDs and GO could be established. • GQDs was employed for casein kinase II activity monitoring and inhibition assay. • Highly sensitive detection of CK2 activity and inhibition was achieved.

  9. Sensitive detection of point mutation by electrochemiluminescence and DNA ligase-based assay

    Science.gov (United States)

    Zhou, Huijuan; Wu, Baoyan

    2008-12-01

    The technology of single-base mutation detection plays an increasingly important role in diagnosis and prognosis of genetic-based diseases. Here we reported a new method for the analysis of point mutations in genomic DNA through the integration of allele-specific oligonucleotide ligation assay (OLA) with magnetic beads-based electrochemiluminescence (ECL) detection scheme. In this assay the tris(bipyridine) ruthenium (TBR) labeled probe and the biotinylated probe are designed to perfectly complementary to the mutant target, thus a ligation can be generated between those two probes by Taq DNA Ligase in the presence of mutant target. If there is an allele mismatch, the ligation does not take place. The ligation products are then captured onto streptavidin-coated paramagnetic beads, and detected by measuring the ECL signal of the TBR label. Results showed that the new method held a low detection limit down to 10 fmol and was successfully applied in the identification of point mutations from ASTC-α-1, PANC-1 and normal cell lines in codon 273 of TP53 oncogene. In summary, this method provides a sensitive, cost-effective and easy operation approach for point mutation detection.

  10. AgNPs-3D nanostructure enhanced electrochemiluminescence of CdSe quantum dot coupled with strand displacement amplification for sensitive biosensing of DNA

    International Nuclear Information System (INIS)

    Jiao, Meng; Jie, Guifen; Tan, Lu; Niu, Shuyan

    2017-01-01

    A novel strategy using Ag nanoparticles-3D (AgNPs-3D) nanostructure enhanced electrochemiluminescence (ECL) of CdSe quantum dots (QDs) coupled with strand displacement amplification (SDA) for sensitive biosensing of DNA was successfully designed. The prepared CdSe QDs with intense ECL were assembled on the poly (diallyldimethylammonium chloride) (PDDA) graphene oxide (GO) nanocomposites modified electrode, then gold nanoparticles (NPs) as the quenching probe was conjugated to the QDs, ECL signal was efficiently quenched. The target DNA induced cycling SDA and generated a large number of DNA s1. The released DNA s1 could open the hairpin DNA with quenching probe. So the presence of low levels of target DNA can potentially result in a significant enhancement of ECL signal. Furthermore, large number of AgNPs were then in situ reduced in the 3D DNA skeleton on the electrode, which dramaticlly enhanced ECL signal of QDs owing to the excellent electrical conductivity, and the much amplified ECL signal change has a quantitative relation with the target DNA. So by combining the AgNPs-3D nanostructure and cycling SDA to achieve greatly amplified detection of DNA, the promising ECL strategy could provide a highly sensitive platform for various biomolecules and has a good prospect for clinical diagnosis in the future. - Graphical abstract: A novel strategy using AgNPs-3D nanostructure enhanced electrochemiluminescence of CdSe quantum dot coupled with DNA strand displacement amplification for sensitive biosensing of DNA was successfully designed, the proposed biosensor can be expected to be an emerging alternative for straightforward nucleic acid detection in complex samples with an easy and rapid way. - Highlights: • AgNPs-3D nanostructure for enhancing ECL signal of CdSe QDs was successfully designed. • A new dual amplification strategy for detection of DNA by using AgNPs-3D nanostructure coupled with SDA was developed. • It is for the first time AgNPs-3D nanostructure

  11. Localized Electrochemiluminescence from Nanoneedle Electrodes for Very-high-density Electrochemical Sensing

    KAUST Repository

    Zhang, Jingjing

    2017-09-28

    In this paper, localized electrochemiluminescence (ECL) was visualized from nanoneedle electrodes that achieved very-high-density electrochemical sensing. The localized luminescence at the nanometer-sized tip observed was ascribed to enhanced mass transfer of the luminescence probe at the tip than on the planar surface surrounding the tip, which provided higher luminescence at the tip. The size of the luminescence spots was restricted to 15 μm permitting the electrochemical analysis with a density over 4 × 103 spots/mm2. The positive correlation between the luminescence intensity at the tips and the concentration of hydrogen peroxide supported the quantitative ECL analysis using nanoneedle electrodes. The further modification of glucose oxidase at the electrode surface conceptually demonstrated that the concentration of glucose ranging from 0.5 to 5 mM could be quantified using the luminescence at the tips, which could be further applied for the detection of multiple molecules in the complex biosystem. This successful localized ECL offers a specific strategy for the development of very-high-density electrochemical arrays without the complicated chip design.

  12. Electrochemiluminescence resonance energy transfer between graphene quantum dots and graphene oxide for sensitive protein kinase activity and inhibitor sensing.

    Science.gov (United States)

    Liang, Ru-Ping; Qiu, Wei-Bin; Zhao, Hui-Fang; Xiang, Cai-Yun; Qiu, Jian-Ding

    2016-01-21

    Herein, a novel electrochemiluminescence resonance energy transfer (ECL-RET) biosensor using graphene quantum dots (GQDs) as donor and graphene oxide (GO) as acceptor for monitoring the activity of protein kinase was presented for the first time. Anti-phosphoserine antibody conjugated graphene oxide (Ab-GO) nonocomposite could be captured onto the phosphorylated peptide/GQDs modified electrode surface through antibody-antigen interaction in the presence of casein kinase II (CK2) and adenosine 5'-triphosphate (ATP), resulting in ECL from the GQDs quenching by closely contacting GO. This ECL quenching degree was positively correlated with CK2 activity. Therefore, on the basis of ECL-RET between GQDs and GO, the activity of protein kinase can be detected sensitively. This biosensor can also be used for quantitative analysis CK2 activity in serum samples and qualitative screening kinase inhibition, indicating the potential application of the developed method in biochemical fundamental research and clinical diagnosis. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Rapid and sensitive electrochemiluminescence detection of rotavirus by magnetic primer based reverse transcription-polymerase chain reaction

    International Nuclear Information System (INIS)

    Zhan Fangfang; Zhou Xiaoming; Xing Da

    2013-01-01

    Graphical abstract: In this work, we have developed and demonstrated a magnetic primer based RT-PCR assay for ECL detection of rotavirus. In the presence of two functional primers (magnetic primer and TBR-primer) and PCR reagents, cDNA from RT was amplified directly onto MPs during PCR cycles of denaturation, annealing and extension. The resulting MPs–TBR complexes were easily loaded on the electrode surface and produced a concentrated ECL signal. The figure shows the schematic illustration of magnetic primer RT-PCR based ECL assay for rotavirus detection. Highlights: ► A novel method for detection of rotavirus has been developed. ► In the presence of magnetic primer, TBR-primer and PCR reagents, cDNA form RT was amplified directly onto MPs. ► To obtain the best sensing and efficient performance, important parameters associated with the efficiency were investigated carefully. ► The proposed method will find numerous applications in food safety field and clinical diagnosis. - Abstract: A novel method for detection of rotavirus has been developed by integrating magnetic primer based reverse transcription-polymerase chain reaction (RT-PCR) with electrochemiluminescence (ECL) detection. This is realized by accomplishing RT of rotavirus RNA in traditional way and performing PCR of the resulting cDNA fragment on the surface of magnetic particles (MPs). In order to implement PCR on MPs and achieve rapid ECL detection, forward and reverse primers are bounded to MPs and tris-(2,2′-bipyridyl) ruthenium (TBR), respectively. After RT-PCR amplification, the TBR labels are directly enriched onto the surface of MPs. Then the MPs–TBR complexes can be loaded on the electrode surface and analyzed by magnetic ECL platform without any post-modification or post-incubation process. So some laborious manual operations can be avoided to achieve rapid yet sensitive detection. In this study, rotavirus in fecal specimens was successfully detected within 1.5 h. Experimental

  14. Rapid and sensitive electrochemiluminescence detection of rotavirus by magnetic primer based reverse transcription-polymerase chain reaction

    Energy Technology Data Exchange (ETDEWEB)

    Zhan Fangfang; Zhou Xiaoming [MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631 (China); Xing Da, E-mail: xingda@scnu.edu.cn [MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631 (China)

    2013-01-25

    Graphical abstract: In this work, we have developed and demonstrated a magnetic primer based RT-PCR assay for ECL detection of rotavirus. In the presence of two functional primers (magnetic primer and TBR-primer) and PCR reagents, cDNA from RT was amplified directly onto MPs during PCR cycles of denaturation, annealing and extension. The resulting MPs-TBR complexes were easily loaded on the electrode surface and produced a concentrated ECL signal. The figure shows the schematic illustration of magnetic primer RT-PCR based ECL assay for rotavirus detection. Highlights: Black-Right-Pointing-Pointer A novel method for detection of rotavirus has been developed. Black-Right-Pointing-Pointer In the presence of magnetic primer, TBR-primer and PCR reagents, cDNA form RT was amplified directly onto MPs. Black-Right-Pointing-Pointer To obtain the best sensing and efficient performance, important parameters associated with the efficiency were investigated carefully. Black-Right-Pointing-Pointer The proposed method will find numerous applications in food safety field and clinical diagnosis. - Abstract: A novel method for detection of rotavirus has been developed by integrating magnetic primer based reverse transcription-polymerase chain reaction (RT-PCR) with electrochemiluminescence (ECL) detection. This is realized by accomplishing RT of rotavirus RNA in traditional way and performing PCR of the resulting cDNA fragment on the surface of magnetic particles (MPs). In order to implement PCR on MPs and achieve rapid ECL detection, forward and reverse primers are bounded to MPs and tris-(2,2 Prime -bipyridyl) ruthenium (TBR), respectively. After RT-PCR amplification, the TBR labels are directly enriched onto the surface of MPs. Then the MPs-TBR complexes can be loaded on the electrode surface and analyzed by magnetic ECL platform without any post-modification or post-incubation process. So some laborious manual operations can be avoided to achieve rapid yet sensitive detection

  15. Gold-coated polydimethylsiloxane microwells for high-throughput electrochemiluminescence analysis of intracellular glucose at single cells.

    Science.gov (United States)

    Xia, Juan; Zhou, Junyu; Zhang, Ronggui; Jiang, Dechen; Jiang, Depeng

    2018-06-04

    In this communication, a gold-coated polydimethylsiloxane (PDMS) chip with cell-sized microwells was prepared through a stamping and spraying process that was applied directly for high-throughput electrochemiluminescence (ECL) analysis of intracellular glucose at single cells. As compared with the previous multiple-step fabrication of photoresist-based microwells on the electrode, the preparation process is simple and offers fresh electrode surface for higher luminescence intensity. More luminescence intensity was recorded from cell-retained microwells than that at the planar region among the microwells that was correlated with the content of intracellular glucose. The successful monitoring of intracellular glucose at single cells using this PDMS chip will provide an alternative strategy for high-throughput single-cell analysis. Graphical abstract ᅟ.

  16. A highly stable electrochemiluminescence sensing system of cadmium sulfide nanowires/graphene hybrid for supersensitive detection of pentachlorophenol

    Science.gov (United States)

    Deng, Yanan; Chang, Quanying; Yin, Kai; Liu, Chengbin; Wang, Ying

    2017-10-01

    A highly stable and effective electrochemiluminescence (ECL) sensing system of cadmium sulfide nanowires/reduced graphene oxide (CdS NWS/rGO) hybrid is presented for supersensitive detection of pentachlorophenol (PCP). CdS nanowire is for the first time exploited in ECL sensing. The rGO served as both ECL signal amplifier and immobilization platform, can perfectly enhance the ECL intensity and stability of the sensing system. With S2O82- as coreactant, the ECL signal can be significantly quenched by the addition of PCP. The established ECL sensing system presents a wider linear range from 1.0 × 10-14 to 1.0 × 10-8 M and a much low detection limit of 2 × 10-15 M under the optimum test conditions (e.g., pH 7.0 and 100 mM S2O82-). Furthermore, the ECL sensing system displays a good selectivity for PCP detection. The practicability of the ECL sensing system in real water sample shows that this system could be promisingly applied in the analytical detection of PCP in real water environments.

  17. Electrochemiluminescence of luminol enhanced by the synergetic catalysis of hemin and silver nanoparticles for sensitive protein detection.

    Science.gov (United States)

    Jiang, Xinya; Chai, Yaqin; Wang, Haijun; Yuan, Ruo

    2014-04-15

    A novel and ultrasensitive electrochemiluminescence (ECL) immunosensor, which was based on the amplifying ECL of luminol by hemin-reduced graphene oxide (hemin-rGO) and Ag nanoparticles (AgNPs) decorated reduced graphene oxide (Ag-rGO), was constructed for the detection of carcinoembryonic antigen (CEA). For this proposed sandwich-type ECL immunosensor, Au nanoparticles electrodeposited (DpAu) onto hemin-rGO (DpAu/hemin-rGO) constructed the base of the immunosensor. DpAu had outstanding electrical conductivity to promote the electron transfer at the electrode interface and had good biocompatibility to load large amounts of primary antibody (Ab1), which provided an excellent platform for this immunosensor. Moreover, AgNPs and glucose oxidase (GOD) functionalized graphene labeled secondary antibody (Ag-rGO-Ab2-GOD) was designed as the signal probe for the sandwiched immunosensor. Not only did the hemin-rGO improve the electron transfer of the electrode surface, but hemin also further amplified the ECL signal of luminol in the presence of hydrogen peroxide (H2O2). With the aid of Ag-rGO-Ab2-GOD, enhanced signal was obtained by in situ generation of H2O2 and catalysis of AgNPs to ECL reaction of the luminol-H2O2 system. The as-prepared ECL immunosensor exhibited excellent analytical property for the detection of CEA in the range from 0.1 pg mL(-1) to 160 ng mL(-1) with a detection limit of 0.03 pg mL(-1) (SN(-1)=3). © 2013 Published by Elsevier B.V.

  18. Sensitive electrochemiluminescence biosensor based on Au-ITO hybrid bipolar electrode amplification system for cell surface protein detection.

    Science.gov (United States)

    Wu, Mei-Sheng; Yuan, Da-Jing; Xu, Jing-Juan; Chen, Hong-Yuan

    2013-12-17

    Here we developed a novel hybrid bipolar electrode (BPE)-electrochemiluminescence (ECL) biosensor based on hybrid bipolar electrode (BPE) for the measurement of cancer cell surface protein using ferrocence (Fc) labeled aptamer as signal recognition and amplification probe. According to the electric neutrality of BPE, the cathode of U-shaped ITO BPE was electrochemically deposited by Au nanoparticles (NPs) to enhance its conductivity and surface area, decrease the overpotential of O2 reduction, which would correspondingly increase the oxidation current of Ru(bpy)3(2+)/tripropylamine (TPA) on the anode of BPE and resulting a ∼4-fold enhancement of ECL intensity. Then a signal amplification strategy was designed by introducing Fc modified aptamer on the anode surface of BPE through hybridization for detecting the amount of mucin-1 on MCF-7 cells. The presence of Fc could not only inhibit the oxidation of Ru(bpy)3(2+) because of its lower oxidation potential, its oxidation product Fc(+) could also quench the ECL of Ru(bpy)3(2+)/TPA by efficient energy-transfer from the excited-state Ru(bpy)3(2+)* to Fc(+), making the ECL intensity greatly quenched. On the basis of the cathodic Au NPs induced ECL enhancing coupled with anodic Fc induced signal quenching amplification, the approach allowed detection of mucin-1 aptamer at a concentration down to 0.5 fM and was capable of detecting a minimum of 20 MCF-7 cells. Besides, the amount of mucin-1 on MCF-7 cells was calculated to be 9041 ± 388 molecules/cell. This approach therefore shows great promise in bioanalysis.

  19. A highly performing electrochemiluminescent biosensor for glucose based on a polyelectrolyte-chitosan modified electrode

    International Nuclear Information System (INIS)

    Dai Hong; Wu Xiaoping; Xu Huifeng; Wang Youmei; Chi Yuwu; Chen Guonan

    2009-01-01

    A highly performing ECL glucose biosensor was developed by immobilizing glucose oxidase (GOD) onto a membrane modified glassy carbon electrode, which was prepared by using poly(diallyldimethylammonium chloride) (PDDA) doped with chitosan. In order to obtain the optimal performance of the ECL biosensor, the composition of modified membranes and a series of measurement conditions were investigated. Under the optimal conditions, this ECL biosensor was able to detect glucose in the range of 0.5-4.0 x 10 4 nM with a detection limit of 0.1 nM (defined as the concentration that could be detected at the signal-to-noise ratio of 3). The relative standard deviation was 0.99% for 5 x 10 -8 mol/L glucose in repetitive measurements in the primary 12 potential cycles. This ECL biosensor offered the effectively improved stability of the electron transfer mediator and exhibited excellent properties for the ultrasensitive and selective determination of glucose with good reproducibility and stability. The present biosensor has also been used to determine the glucose concentrations in real serum samples. The recovery value for the assay of glucose ranged from 96.2 to 107% in the serum samples. The present biosensor displayed both specificity for glucose and retention of signal response even in a complex environment. Therefore, it provided an approach to the sensitive determination of glucose.

  20. Mechanism study on inorganic oxidants induced inhibition of Ru(bpy)₃²+ electrochemiluminescence and its application for sensitive determination of some inorganic oxidants.

    Science.gov (United States)

    Qiu, Bin; Xue, Lingling; Wu, Yanping; Lin, Zhenyu; Guo, Longhua; Chen, Guonan

    2011-07-15

    Inhibited Ru(bpy)(3)(2+) electrochemiluminescence by inorganic oxidants is investigated. Results showed that a number of inorganic oxidants can quench the ECL of Ru(bpy)(3)(2+)/tri-n-propylamine (TPrA) system, and the logarithm of the decrease in ECL intensity (ΔI) was proportional to the logarithm of analyte concentrations. Based on which, a sensitive approach for detection of these inorganic oxidants was established, e.g. the log-log plots of ΔI versus the concentration of MnO(4)(-), Cr(2)O(7)(2-) and Fe(CN)(6)(3-) are linear in the range of 1×10(-7) to 3×10(-4)M for MnO(4)(-) and Cr(2)O(7)(2-), and 1×10(-7) to 1×10(-4)M for Fe(CN)(6)(3-), with the limit of detection (LOD) of 8.0×10(-8)M, 2×10(-8)M, and 1×10(-8)M, respectively. A series of experiments such as a comparison of the inhibitory effect of different compounds on Ru(bpy)(3)(2+)/TPrA ECL, ECL emission spectra, UV-Vis absorption spectra etc. were investigated in order to discover how these inorganic analytes quench the ECL of Ru(bpy)(3)(2+)/TPrA system. A mechanism based on consumption of TPrA intermediate (TPrA(·)) by inorganic oxidants was proposed. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Detection of Abrin by Electrochemiluminescence Biosensor Based on Screen Printed Electrode

    Directory of Open Access Journals (Sweden)

    Shuai Liu

    2018-01-01

    Full Text Available For the convenience of fast measurement in the outdoor environment, a portable electrochemiluminescence biosensor with the screen-printed electrode as the reaction center was developed, which possesses the characteristics of high sensitivity, small scale, simplified operation and so on, and has been used for in situ detection of abrin. First, combining with magnetic separation technique, the “biotin-avidin” method was used to immobilize the polyclonal antibody (pcAb on the magnetic microspheres surface as the capture probe. Secondly, the Ru(bpy32+-labeled monoclonal antibody (mcAb was used as the specific electrochemiluminescence signal probe. Then, the “mcAb-toxin-pcAb” sandwich model was built to actualize the quantitative detection of abrin on the surface of the screen-printed electrode. The linear detection range was 0.5–1000 ng/mL; the regression equation was Y = 89.251lgX + 104.978 (R = 0.9989, n = 7, p < 0.0001; and the limit of detection (LOD was 0.1 ng/mL. The sensing system showed high sensitivity, excellent specificity and good anti-interference ability, and could be used for the analysis of trace abrin in various environmental samples with good recovery and reproducibility. Compared with the traditional electrochemiluminescence sensing device, its miniaturization and portability gives it potential to satisfy the requirement of in situ detection.

  2. Highly efficient quenching of tris(2,2'-bipyridyl)ruthenium(II) electrochemiluminescence by ozone using formaldehyde, methylglyoxal, and glyoxalate as co-reactants and its application to ozone sensing.

    Science.gov (United States)

    Gao, Ying; Liu, Xiaoyun; Qi, Wenjing; Gao, Wenyue; Li, Yunhui; Xu, Guobao

    2015-06-21

    Most electrochemiluminescence (ECL) systems require high concentrations of quencher to totally quench ECL. In this study, we found that ozone can quench tris(2,2'-bipyridyl)ruthenium(II) ECL using formaldehyde, methylglyoxal, or glyoxalate as co-reactants at a glassy carbon electrode with remarkable efficiencies even when the concentration of ozone is merely 0.25% of that of the co-reactant. The strongest quenching is observed with the tris(2,2'-bipyridyl)ruthenium(II)/formaldehyde ECL system. The tris(2,2'-bipyridyl)ruthenium(II)/formaldehyde ECL intensities decrease linearly with the ozone concentration over the range of 0.025-25 μM (r = 0.9947) with a limit of detection of 8 nM. The method is more sensitive and faster than most methods. It shows high selectivity in the presence of other ROS or oxidants and some metal ions, such as H2O2, ClO(-), Mg(2+), Ni(2+), etc. The method exhibits high recoveries for the detection of ozone in a ventilated photocopy room.

  3. Strong enhancement of the electrochemiluminescence of luminol by AuAg and PtAg alloy nanoclusters, and its sensitization by phenolic artificial oestrogens

    International Nuclear Information System (INIS)

    Wang, Ke; Tu, Yifeng; Wei, Xiuhua

    2014-01-01

    This paper reports on the synthesis of AuAg and PtAg alloy nanoclusters (NCs) and their enhancement effect on the electrochemiluminescence (ECL) of luminol. The conditions of synthesis were optimized, and the structure and properties of the NCs were characterized by X-ray diffraction, transmission electron microscopy, electrochemistry, and optical spectroscopy. The NCs are found to intensify (by up to 20 times) the ECL of luminol in solution of pH 8.5. This finding can largely extend the useful pH range of the ECL of luminol. The enhanced ECL is strongly affected by oxygen and hydrogen peroxide, and the mechanism of enhancement is attributed to the accelerated production of reactive oxygen species. The enhanced ECL is also affected by phenolic artificial estrogens, and this was used for their determination with detection limits as low as 700 pg L −1 (with AuAg) and 1.6 ng L −1 (with PtAg). The method was applied to the determination of such estrogens in egg samples using diethylstilbestrol as a reference substance. (author)

  4. A novel probe density controllable electrochemiluminescence biosensor for ultra-sensitive detection of Hg2+ based on DNA hybridization optimization with gold nanoparticles array patterned self-assembly platform.

    Science.gov (United States)

    Gao, Wenhua; Zhang, An; Chen, Yunsheng; Chen, Zixuan; Chen, Yaowen; Lu, Fushen; Chen, Zhanguang

    2013-11-15

    Biosensor based on DNA hybridization holds great potential to get higher sensitivity as the optimal DNA hybridization efficiency can be achieved by controlling the distribution and orientation of probe strands on the transducer surface. In this work, an innovative strategy is reported to tap the sensitivity potential of current electrochemiluminescence (ECL) biosensing system by dispersedly anchoring the DNA beacons on the gold nanoparticles (GNPs) array which was electrodeposited on the glassy carbon electrode surface, rather than simply sprawling the coil-like strands onto planar gold surface. The strategy was developed by designing a "signal-on" ECL biosensing switch fabricated on the GNPs nanopatterned electrode surface for enhanced ultra-sensitivity detection of Hg(2+). A 57-mer hairpin-DNA labeled with ferrocene as ECL quencher and a 13-mer DNA labeled with Ru(bpy)3(2+) as reporter were hybridized to construct the signal generator in off-state. A 31-mer thymine (T)-rich capture-DNA was introduced to form T-T mismatches with the loop sequence of the hairpin-DNA in the presence of Hg(2+) and induce the stem-loop open, meanwhile the ECL "signal-on" was triggered. The peak sensitivity with the lowest detection limit of 0.1 nM was achieved with the optimal GNPs number density while exorbitant GNPs deposition resulted in sensitivity deterioration for the biosensor. We expect the present strategy could lead the renovation of the existing probe-immobilized ECL genosensor design to get an even higher sensitivity in ultralow level of target detection such as the identification of genetic diseases and disorders in basic research and clinical application. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Chiral determination of cinchonine using an electrochemiluminescent sensor with molecularly imprinted membrane on the surfaces of magnetic particles.

    Science.gov (United States)

    Yuan, Xingyi; Tan, Yanji; Wei, Xiaoping; Li, Jianping

    2017-11-01

    A novel molecular imprinting electrochemiluminescence sensor for detecting chiral cinchonine molecules was developed with a molecularly imprinted polymer membrane on the surfaces of magnetic microspheres. Fe 3 O 4 @Au nanoparticles modified with 6-mercapto-beta-cyclodextrin were used as a carrier, cinchonine as a template molecule, methacrylic acid as a functional monomer and N,N'-methylenebisacrylamide as a cross-linking agent. Cinchonine was specifically recognized by the 6-mercapto-beta-cyclodextrin functional molecularly imprinted polymer and detected based on enhancement of the electrochemiluminescence intensity caused by the reaction of tertiary amino structures of cinchonine molecules with Ru(bpy) 3 2+ . Cinchonine concentrations of 1 × 10 -10 to 4 × 10 -7  mol/L showed a good linear relationship with changes of the electrochemiluminescence intensity, and the detection limit of the sensor was 3.13 × 10 -11  mol/L. The sensor has high sensitivity and selectivity, and is easy to renew. It was designed for detecting serum samples, with recovery rates of 98.2% to 107.6%. Copyright © 2017 John Wiley & Sons, Ltd.

  6. High-Sensitivity Spectrophotometry.

    Science.gov (United States)

    Harris, T. D.

    1982-01-01

    Selected high-sensitivity spectrophotometric methods are examined, and comparisons are made of their relative strengths and weaknesses and the circumstances for which each can best be applied. Methods include long path cells, noise reduction, laser intracavity absorption, thermocouple calorimetry, photoacoustic methods, and thermo-optical methods.…

  7. Highly Sensitive Optical Receivers

    CERN Document Server

    Schneider, Kerstin

    2006-01-01

    Highly Sensitive Optical Receivers primarily treats the circuit design of optical receivers with external photodiodes. Continuous-mode and burst-mode receivers are compared. The monograph first summarizes the basics of III/V photodetectors, transistor and noise models, bit-error rate, sensitivity and analog circuit design, thus enabling readers to understand the circuits described in the main part of the book. In order to cover the topic comprehensively, detailed descriptions of receivers for optical data communication in general and, in particular, optical burst-mode receivers in deep-sub-µm CMOS are presented. Numerous detailed and elaborate illustrations facilitate better understanding.

  8. Electrochemiluminescent graphene quantum dots enhanced by MoS2 as sensing platform: a novel molecularly imprinted electrochemiluminescence sensor for 2-methyl-4-chlorophenoxyacetic acid assay

    International Nuclear Information System (INIS)

    Yang, Yukun; Fang, Guozhen; Wang, Xiaomin; Zhang, Fuyuan; Liu, Jingmin; Zheng, Wenjie; Wang, Shuo

    2017-01-01

    Highlights: • Electrochemiluminescent MoS 2 -GQDs nanocomposite was fabricated for the first time. • MoS 2 -GQDs hybrid nanocomposite was used as ECL sensing platform. • Molecularly imprinted ECL sensor was fabricated for the determination of MCPA. • MoS 2 -GQDs nanocomposite may advance the developments of ECL sensor. - Abstract: The ECL properties and application of a novel luminescent material molybdenum disulfide-graphene quantum dots (MoS 2 -GQDs) hybrid nanocomposite was reported for the first time. The hybridization of MoS 2 and GQDs endowed nanocomposite with structural and compositional advantages for boosting the ECL performance of GQDs. Impressively, the ECL could be remarkable enhanced using MoS 2 -GQDs hybrid nanocomposite, which was ∼13, ∼185 and ∼596-folds larger than the ECL intensity of GQDs, MoS 2 modified electrodes and bare electrode, respectively. Subsequently, as a sensing platform, the MoS 2 -GQDs hybrid nanocomposite was applied to fabricate molecularly imprinted electrochemiluminescence sensor for the ultrasensitive and selective determination of 2-methyl-4-chlorophenoxyacetic acid. Under optimal conditions, the detection limit of the prepared sensor was 5.5 pmol L −1 (S/N = 3) within a linear concentration range of 10 pmol L −1 –0.1 μmol L −1 . The developped sensor exhibited high sensitivity, good selectivity, reproducibility and stability, suggesting the potential for detecting pesticides and veterinary drugs at trace levels in food safety and environmental control.

  9. Electrochemiluminescent detection of Pb{sup 2+} by graphene/gold nanoparticles and CdSe quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Liping, E-mail: lipinglu@bjut.edu.cn; Guo, Linqing; Li, Jiao; Kang, Tianfang; Cheng, Shuiyuan

    2016-12-01

    Highlights: • An ECL sensor was fabricated based on the distance dependent between CdSe QDs and gold nanoparticles. • The ssDNA strands rich in G bases adopt the G4 conformation when Pb{sup 2+} is present in detection system. • AuNPs/RGO composite improved the performance of electron transfer of sensor. • The ECL sensor was used to detect Pb{sup 2+} concentration in an actual water sample with high sensitivity and selectivity. - Abstract: A highly sensitive electrochemiluminescent detection method for lead ions (Pb(II)) was fabricated based on the distance-dependent quenching of the electrochemiluminescence from CdSe quantum dots by nanocomposites of graphene and gold nanoparticles. Graphene/gold nanoparticles were electrochemically deposited onto a glassy carbon electrode through the constant potential method. Thiol-labeled DNA was then assembled on the surface of the electrode via gold−sulfur bonding, following which the amino-labeled terminal of the DNA was linked to carboxylated CdSe quantum dots by the formation of amide bonds. The 27-base aptamer was designed with two different domains: the immobilization and detection sequences. The immobilization sequence was paired with 12 complementary bases and immobilized on the gold electrode; the single-stranded detection sequence, rich in G bases, formed a G-quadruplex (G4) structure in the presence of Pb{sup 2+}. The formation of G4 shortens the distance between the CdSe quantum dots and the Au electrode, which decreases the electrochemiluminescent intensity in a linear fashion, proportional to the concentration of Pb(II). The linear range of the sensor was 10{sup −10} to 10{sup −8} mol/L (R = 0.9819) with a detection limit of 10{sup −10} mol/L. This sensor detected Pb(II) in real water samples with satisfactory results.

  10. Electrochemiluminescent DNA sensor based on controlled Zn-mediated grafting of diazonium precursors.

    Science.gov (United States)

    Torréns, Mabel; Ortiz, Mayreli; Bejarano-Nosas, Diego; O'Sullivan, Ciara K

    2015-07-01

    Controlled Zn-mediated grafting of a thin layer of a diazonium salt was used to functionalise a carbon electrode with ruthenium(II)-tris-bipyridine (Ru)-labelled DNA for use as a capture probe in an electrochemiluminescent genosensor. A secondary reporter probe was labelled with a ferrocene (Fc) molecule, and in the presence of the single-stranded DNA target a genocomplex formed, where the Fc-label effectively quenched the electrochemiluminescence of the signal emitted from the Ru-label. The spacing of the labels for maximum sensitivity and minimum detection limit was optimised, and the signal reproducibility and stability of the method was established.

  11. Rapid Detection of Clostridium botulinum Toxins A, B, E, and F in Clinical Samples, Selected Food Matrices, and Buffer Using Paramagnetic Bead-Based Electrochemiluminescence Detection

    National Research Council Canada - National Science Library

    Rivera, Victor R; Gamez, Frank J; Keener, William K; White, Jill A; Poli, Mark A

    2006-01-01

    Sensitive and specific electrochemiluminescence (ECL) assays were used to detect Clostridium botulinum neurotoxins serotypes A, B, E, and F in undiluted human serum, undiluted human urine, assay buffer, and selected food matrices...

  12. Immunoassay of C-reactive protein by hot electron induced electrochemiluminescence using integrated electrodes with hydrophobic sample confinement

    Energy Technology Data Exchange (ETDEWEB)

    Ylinen-Hinkka, T., E-mail: tiina.ylinen-hinkka@aalto.fi [Laboratory of Analytical Chemistry, Aalto University School of Chemical Technology, P.O. Box 16100, FI-00076 Aalto (Finland); Niskanen, A.J.; Franssila, S. [Department of Materials Science and Engineering, Aalto University School of Chemical Technology, P.O. Box 16200, FI-00076 Aalto (Finland); Kulmala, S. [Laboratory of Analytical Chemistry, Aalto University School of Chemical Technology, P.O. Box 16100, FI-00076 Aalto (Finland)

    2011-09-19

    Highlights: {center_dot} C-reactive protein has been determined in the concentration range 0.01-10 mg L{sup -1} using an electrochemiluminescence microchip which employs integrated electrodes with hydrophobic sample confinement. {center_dot} This arrangement enables very simple and fast CRP analysis amenable to point-of-care applications. - Abstract: C-reactive protein (CRP) was determined in the concentration range 0.01-10 mg L{sup -1} using hot electron induced electrochemiluminescence (HECL) with devices combining both working and counter electrodes and sample confinement on a single chip. The sample area on the electrodes was defined by a hydrophobic ring, which enabled dispensing the reagents and the analyte directly on the electrode. Immunoassay of CRP by HECL using integrated electrodes is a good candidate for a high-sensitivity point-of-care CRP-test, because the concentration range is suitable, miniaturisation of the measurement system has been demonstrated and the assay method with integrated electrodes is easy to use. High-sensitivity CRP tests can be used to monitor the current state of cardiovascular disease and also to predict future cardiovascular problems in apparently healthy people.

  13. Sandwich-Type Electrochemiluminescence Sensor for Detection of NT-proBNP by Using High Efficiency Quench Strategy of Fe3O4@PDA toward Ru(bpy)32+ Coordinated with Silver Oxalate.

    Science.gov (United States)

    Shi, Li; Li, Xiaojian; Zhu, Wenjuan; Wang, Yaoguang; Du, Bin; Cao, Wei; Wei, Qin; Pang, Xuehui

    2017-12-22

    Heart failure (HF) is a burgeoning public health problem trigged by a heart circulation disorder. N-terminal pro-B-type natriuretic peptide (NT-proBNP) has been acknowledged as a prognostic biomarker for cardiac disease. Herein, a sandwich-type electrochemiluminescence (ECL) immunosensor was introduced for sensitive detection of NT-proBNP. Gold nanoparticle modified graphene oxide-Ru(bpy) 3 2+ /Ag 2 C 2 O 4 was used as a luminophore and a desirable platform for immobilization of the captured antibodies. The more stable immobilization of plentiful Ru(bpy) 3 2+ could be implemented by direct covalent bonding chelation with Ag 2 C 2 O 4 . More importantly, significant quenching can be achieved by introducing polydopamine (PDA) coated Fe 3 O 4 onto the electrode via sandwich immunoreactions. The quenching mechanism mainly showed that the excited states of Ru(bpy) 3 2+ could be annihilated by quinone units in PDA via energy transfer. The ECL quenching efficiency was logarithmically related to the concentration of the NT-proBNP in the range from 0.0005 ng/mL to 100.0 ng/mL with a detection limit of 0.28 pg/mL. Furthermore, this specific immunosensor presented good stability and repeatability as well as selectivity, which offers a guiding significance in both fundamental and clinical diagnosis of NT-proBNP.

  14. High order depletion sensitivity analysis

    International Nuclear Information System (INIS)

    Naguib, K.; Adib, M.; Morcos, H.N.

    2002-01-01

    A high order depletion sensitivity method was applied to calculate the sensitivities of build-up of actinides in the irradiated fuel due to cross-section uncertainties. An iteration method based on Taylor series expansion was applied to construct stationary principle, from which all orders of perturbations were calculated. The irradiated EK-10 and MTR-20 fuels at their maximum burn-up of 25% and 65% respectively were considered for sensitivity analysis. The results of calculation show that, in case of EK-10 fuel (low burn-up), the first order sensitivity was found to be enough to perform an accuracy of 1%. While in case of MTR-20 (high burn-up) the fifth order was found to provide 3% accuracy. A computer code SENS was developed to provide the required calculations

  15. Enhanced electrochemiluminescence of CdTe quantum dots with carbon nanotube film and its sensing of methimazole

    International Nuclear Information System (INIS)

    Hua Lijuan; Han Heyou; Chen Haibo

    2009-01-01

    A novel analytical method was reported based on electrochemiluminescence (ECL) of CdTe quantum dots (QDs) using carbon nanotube (CNT) modified glass carbon (GC) electrode. It was found that the CNT film on the GC electrode could greatly enhance the ECL intensity of CdTe QDs dispersed in aqueous solution, and the ECL peak potential and ECL onset potential both shifted positively. Influences of some factors on the ECL intensity were investigated using CNT modified GC electrode, and a high sensitive method for the determination of methimazole was developed under the optimal conditions. The ECL intensity decreased linearly in the concentration range of 1.0 x 10 -9 to 4.0 x 10 -7 M for methimazole with the relative coefficient of 0.995, which showed finer sensitivity than that at bare electrode. Thus, CNT modified electrode would have a great merit to expand the application of QD ECL

  16. A label-free electrochemiluminescent sensor for ATP detection based on ATP-dependent ligation.

    Science.gov (United States)

    Zhao, Tingting; Lin, Chunshui; Yao, Qiuhong; Chen, Xi

    2016-07-01

    In this work, we describe a new label-free, sensitive and highly selective strategy for the electrochemiluminescent (ECL) detection of ATP at the picomolar level via ATP-induced ligation. The molecular-beacon like DNA probes (P12 complex) are self-assembled on a gold electrode. The presence of ATP leads to the ligation of P12 complex which blocks the digestion by Exonuclease III (Exo III). The protected P12 complex causes the intercalation of numerous ECL indicators (Ru(phen)3(2+)) into the duplex DNA grooves, resulting in significantly amplified ECL signal output. Since the ligating site of T4 DNA ligase and the nicking site of Exo III are the same, it involves no long time of incubation for conformation change. The proposed strategy combines the amplification power of enzyme and the inherent high sensitivity of the ECL technique and enables picomolar detection of ATP. The developed strategy also shows high selectivity against ATP analogs, which makes our new label-free and highly sensitive ligation-based method a useful addition to the amplified ATP detection arena. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. In-electrode vs. on-electrode: ultrasensitive Faraday cage-type electrochemiluminescence immunoassay.

    Science.gov (United States)

    Guo, Zhiyong; Sha, Yuhong; Hu, Yufang; Wang, Sui

    2016-03-28

    A new-concept of an "in-electrode" Faraday cage-type electrochemiluminescence immunoassay (ECLIA) method for the ultrasensitive detection of neurotensin (NT) was reported with capture antibody (Ab1)-nanoFe3O4@graphene (GO) and detector antibody (Ab2)&N-(4-aminobutyl)-N-ethylisoluminol (ABEI)@GO, which led to about 1000-fold improvement in sensitivity by extending the Helmholtz plane (OHP) of the proposed electrode assembly effectively.

  18. Electrochemiluminescence polymerase chain reaction detection of genetically modified organisms

    International Nuclear Information System (INIS)

    Liu Jinfeng; Xing Da; Shen Xingyan; Zhu Debin

    2005-01-01

    With the development of biotechnology, more and more genetically modified organisms (GMOs) have entered commercial market. Because of the safety concerns, detection and characterization of GMOs have attracted much attention recently. Electrochemiluminescence (ECL) method is a chemiluminescent (CL) reaction of species generated electrochemically on an electrode surface. It is a highly efficient and accurate detection method. In this paper, ECL polymerase chain reaction (PCR) combined with two types of nucleic acid probes hybridization was applied to detect GMOs for the first time. Whether the organisms contain GM components was discriminated by detecting the cauliflower mosaic virus 35S (CaMV35S) promoter and nopaline synthase (NOS) terminator. The experiment results show that the detection limit is 100 fmol of PCR products. The promoter and the terminator can be clearly detected in GMOs. The method may provide a new means for the detection of GMOs due to its simplicity and high efficiency

  19. A review of electrochemiluminescence (ECL) in and for microfluidic analytical devices.

    Science.gov (United States)

    Kirschbaum, Stefanie E K; Baeumner, Antje J

    2015-05-01

    The concept and realization of microfluidic total analysis systems (microTAS) have revolutionized the analytical process by integrating the whole breadth of analytical techniques into miniaturized systems. Paramount for efficient and competitive microTAS are integrated detection strategies, which lead to low limits of detection while reducing the sample volume. The concept of electrochemiluminescence (ECL) has been intriguing ever since its introduction based on Ru(bpy)3 (2+) by Tokel and Bard [1] (J Am Chem Soc 1853:2862-2863, 1972), especially because of its immense sensitivity, nonexistent auto-luminescent background signal, and simplicity in experimental design. Therefore, integrating ECL detection into microTAS is a logical consequence to achieve simple, yet highly sensitive, sensors. However, published microanalytical devices employing ECL detection focus in general on traditional ECL chemistry and have yet to take advantage of advances made in standard bench-top ECL strategies. This review will therefore focus on the most recent advancements in microfluidic ECL approaches, but also evaluate the potential impact of bench-top ECL research progress that would further improve performance and lower limits of detection of micro analytical ECL systems, ensuring their desirability as detection principle for microTAS applications.

  20. Inhomogeneous electrochemiluminescence. II Markovian encounter theory of the phenomenon

    International Nuclear Information System (INIS)

    Gladkikh, V.; Burshtein, A.I.

    2005-01-01

    The free energy dependence of the electro-chemiluminescence quantum yield is specified, with the Markovian encounter theory accounting for the reversibility of triplet production competing with the irreversible recombination to the ground state. It is shown that diffusional ion recombination is highly inhomogeneous in space. It proceeds at either large positive ionization free energy (mainly to the triplet product) or at large negative free energy when recombination to the ground state dominates. On the contrary at medium free energies, the quasi-resonant generation of triplets is under kinetic control and therefore much more homogeneous. In this case, both recombination products are generated in comparable amounts. The multiple reversible ionization is shown to act as an independent quenching mechanism previously unknown. The role of the triplet quenching at the electrode is also specified. These effects reduce noticeably the luminescence quantum yield but only at larger triplet life times and in different free energy regions

  1. DNA tetrahedral scaffolds-based platform for the construction of electrochemiluminescence biosensor.

    Science.gov (United States)

    Feng, Qiu-Mei; Zhou, Zhen; Li, Mei-Xing; Zhao, Wei; Xu, Jing-Juan; Chen, Hong-Yuan

    2017-04-15

    Proximal metallic nanoparticles (NPs) could quench the electrochemiluminescence (ECL) emission of semiconductor quantum dots (QDs) due to Förster energy transfer (FRET), but at a certain distance, the coupling of light-emission with surface plasmon resonance (SPR) result in enhanced ECL. Thus, the modification strategies and distances control between QDs and metallic NPs are critical for the ECL intensity of QDs. In this strategy, a SPR enhanced ECL sensor based on DNA tetrahedral scaffolds modified platform was reported for the detection of telomerase activity. Due to the rigid three-dimensional structure, DNA tetrahedral scaffolds grafting on the electrode surface could accurately modulate the distance between CdS QDs and luminol labelled gold nanoparticles (L-Au NPs), meanwhile provide an enhanced spatial dimension and accessibility for the assembly of multiple L-Au NPs. The ECL intensities of both CdS QDs (-1.25V vs. SCE) and luminol (+0.33V vs. SCE) gradually increased along with the formation of multiple L-Au NPs at the vertex of DNA tetrahedral scaffolds induced by telomerase, bringing in a dual-potential ECL analysis. The proposed method showed high sensitivity for the identification of telomerase and was successfully applied for the differentiation of cancer cells from normal cells. This work suggests that DNA tetrahedral scaffolds could serve as an excellent choice for the construction of SPR-ECL system. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Development of Solid-State Electrochemiluminescence (ECL Sensor Based on Ru(bpy32+-Encapsulated Silica Nanoparticles for the Detection of Biogenic Polyamines

    Directory of Open Access Journals (Sweden)

    Anna-Maria Spehar-Délèze

    2015-05-01

    Full Text Available A solid state electrochemiluminescence (ECL sensor based on Ru(bpy32+-encapsulated silica nanoparticles (RuNP covalently immobilised on a screen printed carbon electrode has been developed and characterised. RuNPs were synthesised using water-in-oil microemulsion method, amino groups were introduced on their surface, and they were characterised by transmission electron microscopy. Aminated RuNPs were covalently immobilised on activate screen-printed carbon electrodes to form a solid state ECL biosensor. The biosensor surfaces were characterised using electrochemistry and scanning electron microscopy, which showed that aminated nanoparticles formed dense 3D layers on the electrode surface thus allowing immobilisation of high amount of Ru(bpy32+. The developed sensor was used for ECL detection of biogenic polyamines, namely spermine, spermidine, cadaverine and putrescine. The sensor exhibited high sensitivity and stability.

  3. Titania nanotubes decorated with gold nanoparticles for electrochemiluminescent biosensing of glycosylated hemoglobin

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Qun [Institute of Analytical Chemistry, Dushu Lake Campus, Soochow University, Industrial Park, Suzhou, 215123 (China); College of Chemistry and Chemical Engineering, Nantong University, Nantong, 226019 (China); Tang, Shan [Institute of Analytical Chemistry, Dushu Lake Campus, Soochow University, Industrial Park, Suzhou, 215123 (China); Fang, Chen [Institute of Analytical Chemistry, Dushu Lake Campus, Soochow University, Industrial Park, Suzhou, 215123 (China); Second Affiliated Hospital, Soochow University, Suzhou, 215004 (China); Tu, Yi-Feng, E-mail: tuyf@suda.edu.cn [Institute of Analytical Chemistry, Dushu Lake Campus, Soochow University, Industrial Park, Suzhou, 215123 (China)

    2016-09-14

    A glycated hemoglobin (HbA1c) biosensor with high performance has been constructed in this work. Here the fructosyl amino acid oxidase was immobilized onto a pre-functionalized indium tin oxide glass with titania nanotubes decorated with gold nanoparticles. The property of nanocomposite was characterized by transmission electromicroscopy, scanning electron microscopy, electrochemistry and spectroscopy. Under the optimum conditions, fructosyl valine was detected by this biosensor. It exhibited a linear detection range from 4.0 × 10{sup −9} M to 7.2 × 10{sup −7} M, and a limit of detection for 3.8 × 10{sup −9} M at the signal-to-noise ratio of 3. Thus the HbA1c level in whole blood samples of healthy individuals or diabetic patients were evaluated with designed biosensor after pre-treatment of hydrolysis. The results of our detection were closely consistent with that of the standard method. At the same time, our biosensor has some advantages including high sensitivity, disposable usage and low cost, which implies its great promising application in point-of-care testing of HbA1c. - Highlights: • The enhanced electrochemiluminescence of luminol by AuNPs/TiNTs. • An ECL biosensor for HbA1c assay with ultra-high sensitivity. • A promising disposable device for diabetic diagnosis and treatment even for POCT. • The excellent regression of detected results with gold-standard method.

  4. Titania nanotubes decorated with gold nanoparticles for electrochemiluminescent biosensing of glycosylated hemoglobin

    International Nuclear Information System (INIS)

    Zhao, Qun; Tang, Shan; Fang, Chen; Tu, Yi-Feng

    2016-01-01

    A glycated hemoglobin (HbA1c) biosensor with high performance has been constructed in this work. Here the fructosyl amino acid oxidase was immobilized onto a pre-functionalized indium tin oxide glass with titania nanotubes decorated with gold nanoparticles. The property of nanocomposite was characterized by transmission electromicroscopy, scanning electron microscopy, electrochemistry and spectroscopy. Under the optimum conditions, fructosyl valine was detected by this biosensor. It exhibited a linear detection range from 4.0 × 10"−"9 M to 7.2 × 10"−"7 M, and a limit of detection for 3.8 × 10"−"9 M at the signal-to-noise ratio of 3. Thus the HbA1c level in whole blood samples of healthy individuals or diabetic patients were evaluated with designed biosensor after pre-treatment of hydrolysis. The results of our detection were closely consistent with that of the standard method. At the same time, our biosensor has some advantages including high sensitivity, disposable usage and low cost, which implies its great promising application in point-of-care testing of HbA1c. - Highlights: • The enhanced electrochemiluminescence of luminol by AuNPs/TiNTs. • An ECL biosensor for HbA1c assay with ultra-high sensitivity. • A promising disposable device for diabetic diagnosis and treatment even for POCT. • The excellent regression of detected results with gold-standard method.

  5. In situ electro-polymerization of nitrogen doped carbon dots and their application in an electrochemiluminescence biosensor for the detection of intracellular lead ions.

    Science.gov (United States)

    Xiong, Chengyi; Liang, Wenbin; Wang, Haijun; Zheng, Yingning; Zhuo, Ying; Chai, Yaqin; Yuan, Ruo

    2016-04-25

    Here, a novel sensitive electrochemiluminescence (ECL) biosensor using N doped carbon dots (N-CDs) in situ electro-polymerized onto a glassy carbon electrode (GCE) as luminophores, and Pd-Au hexoctahedrons (Pd@Au HOHs) as enhancers, was developed for the detection of intracellular lead ions (Pb(2+)).

  6. An enzyme-assisted electrochemiluminescent biosensor developed on order mesoporous carbons substrate for ultrasensitive glyphosate sensing

    International Nuclear Information System (INIS)

    Zhang, Qingrong; Xu, Guifang; Gong, Lingshan; Dai, Hong; Zhang, Shupei; Li, Yilin; Lin, Yanyu

    2015-01-01

    In this paper, a strategy of developing a late-model and sensitive electrochemiluminescence (ECL) biosensor for glyphosate detection based on enzyme-assisted in situ generation of ZnS quantum dots (QDs) on ordered mesoporous carbons (OMC) substrate was proposed. OMC, as a typically ordered mesoporous carbon material, not only provides a protective microenvironment for enzyme to retain its structure and activity but also has a synergistic effect with chitosan for the absorption of Zn 2+ ions by virtue of its high surface area and high pore volume and thus employed as the matrix of proposed biosensor. Then horseradish peroxidase (HRP) was introduced to expedite the generation of ZnS QDs via accelerating the reduction of Na 2 S 2 O 3 with H 2 O 2 to yield H 2 S that reacted with Zn 2+ ions. Glyphosate, as a kind of organic pesticide with amine, carboxyl and phosphonate group which would coordinate strongly to metal ions, possessed the potential to inhibited the activity of HRP, because HRP contain iron (III) protoporphyrin IX (ferriprotoporphyrin IX) as the prosthetic group which would react with the amine, carboxyl and phosphonate group of glyphosate. Accordingly, the proposed ECL QDs biosensor was employed to determine the Gly and shown a wide linear range from 0.1 nM to 10 mM with excellent sensitivity, reproducibility and selectivity. Further, the half maximal inhibitory concentration (IC 50 ) and the Michaelis–Menten constant were studied, and all the results indicated that the proposed strategy is practicable and provide a new opportunity to develop novel ECL sensing platforms in various applications.

  7. A molecularly imprinted electrochemiluminescence sensor based on the mimetic enzyme catalytic effect for ultra-trace Ni2+ determination.

    Science.gov (United States)

    Yang, Bin; Li, Jianping; Zhang, Lianming; Xu, Guobao

    2016-10-21

    A novel molecularly imprinted polymer (MIP) electrochemiluminescence (MIP-ECL) sensor was developed for the highly sensitive and selective determination of ultra-trace levels of Ni 2+ . The complex Ni 2+ -dimethylglyoxime (Ni-DMG) was chosen as the template molecule to construct the MIP and then acted as a mimetic enzyme to catalyse the oxidisation of luminol to enhance the ECL signal. When the imprinted cavities were occupied by Ni-DMG in the rebinding process, the ECL intensities produced by the luminol-H 2 O 2 ECL system on the MIP-modified electrode surface increased with increased concentration of the Ni-DMG complex. The highly sensitive determination of Ni 2+ was achieved through a catalytic reaction. This technique could be used for the quantitative analysis of Ni 2+ with concentrations from 3.0 × 10 -12 mol L -1 to 6.0 × 10 -9 mol L -1 . The detection limit was 1.01 × 10 -12 mol L -1 , which is much lower than that reported previously. In addition, the allowable amounts of interference ions in the MIP-ECL sensor were higher than that in other common molecularly imprinted sensors because of its excellent recognition of 3D cavity-to-complex molecules and ligand-to-metal ions. This method was successfully used to determine Ni 2+ in real samples, such as apples, carrots and grapes, and has been proven feasible for practical applications.

  8. Surface-enhanced molecularly imprinted electrochemiluminescence sensor based on Ru@SiO2 for ultrasensitive detection of fumonisin B1.

    Science.gov (United States)

    Zhang, Wei; Xiong, Huiwen; Chen, Miaomiao; Zhang, Xiuhua; Wang, Shengfu

    2017-10-15

    A novel molecularly imprinted electrochemiluminescence (MIP-ECL) sensor based on Ru(bpy) 3 2+ -doped silica nanoparticles (Ru@SiO 2 NPs) is developed for highly sensitive detection of fumonisin B 1 (FB 1 ). Gold-nanoparticles (AuNPs), Ru@SiO 2 NPs with chitosan (CS) composites and a molecularly imprinted polymer (MIP) are assembled on a glassy carbon electrode (GCE) to fabricate an ECL platform step by step. AuNPs could greatly promote the ECL intensity and improve the analytical sensitivity according to the localized surface plasmon resonance (LSPR) and the electrochemical effect. In this surface-enhanced electrochemiluminescence (SEECL) system, AuNPs work as the LSPR source to improve the ECL intensity and Ru@SiO 2 NPs are used as ECL luminophores. In the phosphate buffer solution (PBS), the evident anodic ECL of Ru@SiO 2 on the above working electrode is observed in the presence of the template molecule fumonisin B 1 (FB 1 ), which could act as the coreactant of Ru@SiO 2 NPs due to the amino group of FB 1 . When the template molecules were eluted from the MIP, little coreactant was left, resulting in an apparent decrease of ECL signal. After the MIP-ECL sensor was incubated in FB 1 solution, the template molecules rebound to the MIP surface, leading to the enhancement of ECL signal again. On the basis of these results, a facile MIP-ECL sensor has been successfully fabricated, which exhibited a linear range from 0.001 to 100ngmL -1 with a detection limit of 0.35pgmL -1 for FB 1 . Moreover, the proposed MIP-ECL sensor displayed an excellent application in real samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Faraday cage-type electrochemiluminescence immunosensor for ultrasensitive detection of Vibrio vulnificus based on multi-functionalized graphene oxide.

    Science.gov (United States)

    Guo, Zhiyong; Sha, Yuhong; Hu, Yufang; Yu, Zhongqing; Tao, Yingying; Wu, Yanjie; Zeng, Min; Wang, Sui; Li, Xing; Zhou, Jun; Su, Xiurong

    2016-10-01

    A novel Faraday cage-type electrochemiluminescence (ECL) immunosensor devoted to the detection of Vibrio vulnificus (VV) was fabricated. The sensing strategy was presented by a unique Faraday cage-type immunocomplex based on immunomagnetic beads (IMBs) and multi-functionalized graphene oxide (GO) labeled with (2,2'-bipyridine)(5-aminophenanthroline)ruthenium (Ru-NH2). The multi-functionalized GO could sit on the electrode surface directly due to the large surface area, abundant functional groups, and good electronic transport property. It ensures that more Ru-NH2 is entirely caged and become "effective," thus improving sensitivity significantly, which resembles extending the outer Helmholtz plane (OHP) of the electrode. Under optimal conditions, the developed immunosensor achieves a limit of detection as low as 1 CFU/mL. Additionally, the proposed immunosensor with high sensitivity and selectivity can be used for the detection of real samples. The novel Faraday cage-type method has shown potential application for the diagnosis of VV and opens up a new avenue in ECL immunoassay. Graphical abstract Faraday cage-type immunoassay mode for ultrasensitive detection by extending OHP.

  10. Comparative performance of electrochemiluminescence immunoassay and EIA for HIV screening in a multiethnic region of China.

    Directory of Open Access Journals (Sweden)

    Xiaohui Bi

    Full Text Available The recent approval of 4th generation HIV tests has forced many laboratories to decide whether to shift from 3rd to these tests. There are limited published studies on the comparative evaluation of these two different assays. We compare the performance of fourth-generation electrochemiluminescence immunoassay (ChIA and third-generation enzyme linked immunosorbent assay (EIA for human immunodeficiency virus (HIV screening and gauge whether the shift from EIA to ChIA could be better in a multiethnic region of China.We identified a large number of routine specimens (345,492 using two different assays from Jan 2008 to Aug 2011 in a teaching hospital with high sample throughput. Of the 344,596 specimens with interpretable HIV test results, 526(0.23% of 228,761 using EIA and 303(0.26% of 115,835 using ChIA were HIV-1 positive. The false-positive rate of EIA was lower than that of ChIA [0.03% vs. 0.08%, odds ratio 0.33 (95% confidence interval 0.24, 0.45]. The positive predictive value (PPV of EIA (89.6% was significantly higher than that of ChIA (76.1% (<0.001, reflecting the difference between the two assays. The clinical sensitivities of two assays in this study were 99.64% for EIA and 99.88% for ChIA.Caution is needed before shifting from 3rd to 4th generation HIV tests. Since none of these tests are perfect, different geographic and ethnic area probably require different considerations with regard to HIV testing methods, taking into account the local conditions.

  11. Comparative performance of electrochemiluminescence immunoassay and EIA for HIV screening in a multiethnic region of China.

    Science.gov (United States)

    Bi, Xiaohui; Ning, Hongxia; Wang, Tingting; Li, Dongdong; Liu, Yongming; Yang, Tingfu; Yu, Jiansheng; Tao, Chuanmin

    2012-01-01

    The recent approval of 4th generation HIV tests has forced many laboratories to decide whether to shift from 3rd to these tests. There are limited published studies on the comparative evaluation of these two different assays. We compare the performance of fourth-generation electrochemiluminescence immunoassay (ChIA) and third-generation enzyme linked immunosorbent assay (EIA) for human immunodeficiency virus (HIV) screening and gauge whether the shift from EIA to ChIA could be better in a multiethnic region of China. We identified a large number of routine specimens (345,492) using two different assays from Jan 2008 to Aug 2011 in a teaching hospital with high sample throughput. Of the 344,596 specimens with interpretable HIV test results, 526(0.23%) of 228,761 using EIA and 303(0.26%) of 115,835 using ChIA were HIV-1 positive. The false-positive rate of EIA was lower than that of ChIA [0.03% vs. 0.08%, odds ratio 0.33 (95% confidence interval 0.24, 0.45)]. The positive predictive value (PPV) of EIA (89.6%) was significantly higher than that of ChIA (76.1%) (<0.001), reflecting the difference between the two assays. The clinical sensitivities of two assays in this study were 99.64% for EIA and 99.88% for ChIA. Caution is needed before shifting from 3rd to 4th generation HIV tests. Since none of these tests are perfect, different geographic and ethnic area probably require different considerations with regard to HIV testing methods, taking into account the local conditions.

  12. Graphite paper-based bipolar electrode electrochemiluminescence sensing platform.

    Science.gov (United States)

    Zhang, Xin; Ding, Shou-Nian

    2017-08-15

    In this work, aiming at the construction of a disposable, wireless, low-cost and sensitive system for bioassay, we report a closed bipolar electrode electrochemiluminescence (BPE-ECL) sensing platform based on graphite paper as BPE for the first time. Graphite paper is qualified as BPE due to its unique properties such as excellent electrical conductivity, uniform composition and ease of use. This simple BPE-ECL device was applied to the quantitative analysis of oxidant (H 2 O 2 ) and biomarker (CEA) respectively, according to the principle of BPE sensing-charge balance. For the H 2 O 2 analysis, Pt NPs were electrodeposited onto the cathode through a bipolar electrodeposition approach to promote the sensing performance. As a result, this BPE-ECL device exhibited a wide linear range of 0.001-15mM with a low detection limit of 0.5µM (S/N=3) for H 2 O 2 determination. For the determination of CEA, chitosan-multi-walled carbon nanotubes (CS-MWCNTs) were employed to supply a hydrophilic interface for immobilizing primary antibody (Ab 1 ); and Au@Pt nanostructures were conjugated with secondary antibody (Ab 2 ) as catalysts for H 2 O 2 reduction. Under the optimal conditions, the BPE-ECL immunodevice showed a wide linear range of 0.01-60ngmL -1 with a detection limit of 5.0pgmL -1 for CEA. Furthermore, it also displayed satisfactory selectivity, excellent stability and good reproducibility. The developed method opened a new avenue to clinical bioassay. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Phase sensitive diffraction sensor for high sensitivity refractive index measurement

    Science.gov (United States)

    Kumawat, Nityanand; Varma, Manoj; Kumar, Sunil

    2018-02-01

    In this study a diffraction based sensor has been developed for bio molecular sensing applications and performing assays in real time. A diffraction grating fabricated on a glass substrate produced diffraction patterns both in transmission and reflection when illuminated by a laser diode. We used zeroth order I(0,0) as reference and first order I(0,1) as signal channel and conducted ratiometric measurements that reduced noise by more than 50 times. The ratiometric approach resulted in a very simple instrumentation with very high sensitivity. In the past, we have shown refractive index measurements both for bulk and surface adsorption using the diffractive self-referencing approach. In the current work we extend the same concept to higher diffraction orders. We have considered order I(0,1) and I(1,1) and performed ratiometric measurements I(0,1)/I(1,1) to eliminate the common mode fluctuations. Since orders I(0,1) and I(1,1) behaved opposite to each other, the resulting ratio signal amplitude increased more than twice compared to our previous results. As a proof of concept we used different salt concentrations in DI water. Increased signal amplitude and improved fluid injection system resulted in more than 4 times improvement in detection limit, giving limit of detection 1.3×10-7 refractive index unit (RIU) compared to our previous results. The improved refractive index sensitivity will help significantly for high sensitivity label free bio sensing application in a very cost-effective and simple experimental set-up.

  14. Determination of sibutramine with a new sensor based on luminol electrochemiluminescence

    International Nuclear Information System (INIS)

    Wang Shaowei; Yu Jinghua; Wan Fuwei; Ge Shenguang; Yan Mei; Zhang Meng

    2011-01-01

    A flow injection electrochemiluminescence (FI-ECL) analysis method for the determination of sibutramine in the presence of luminol was studied under conventional cyclic voltammetry in alkaline Na 2 CO 3 -NaHCO 3 buffer solution (pH 8.0-12.0). This method is based on the enhanced ECL of luminol-sibutramine. Meanwhile, in order to overcome the drawbacks of conventional cells, a FI cell was designed, which is reusable and has a great improvement in sensitivity and selectivity for ECL analysis. Under the optimal experimental conditions, the enhanced ECL intensity was linearly related to the concentration of sibutramine in the range 1.0x10 -8 -1.0x10 -6 g mL -1 with a detection limit of 2.48x10 -9 g mL -1 and a correlation coefficient (R) of 0.9995. The relative standard deviation (RSD) for 1.0x10 -7 g mL -1 samples was 2.1% (n=11). The possible mechanism discussed. The proposed FI-ECL method has been successfully applied to the determination of sibutramine in diet pill samples. - Highlights: → An electrochemiluminescence (ECL) system was studied to determine sibutramine. → A flow injection cell was made to overcome the drawbacks of the conventional ones. → The system was based on the enhanced ECL of luminol-sibutramine. → The system can be satisfactorily applied to determine sibutramine in diet pills.

  15. PCR-free quantitative detection of genetically modified organism from raw materials. An electrochemiluminescence-based bio bar code method.

    Science.gov (United States)

    Zhu, Debin; Tang, Yabing; Xing, Da; Chen, Wei R

    2008-05-15

    A bio bar code assay based on oligonucleotide-modified gold nanoparticles (Au-NPs) provides a PCR-free method for quantitative detection of nucleic acid targets. However, the current bio bar code assay requires lengthy experimental procedures including the preparation and release of bar code DNA probes from the target-nanoparticle complex and immobilization and hybridization of the probes for quantification. Herein, we report a novel PCR-free electrochemiluminescence (ECL)-based bio bar code assay for the quantitative detection of genetically modified organism (GMO) from raw materials. It consists of tris-(2,2'-bipyridyl) ruthenium (TBR)-labeled bar code DNA, nucleic acid hybridization using Au-NPs and biotin-labeled probes, and selective capture of the hybridization complex by streptavidin-coated paramagnetic beads. The detection of target DNA is realized by direct measurement of ECL emission of TBR. It can quantitatively detect target nucleic acids with high speed and sensitivity. This method can be used to quantitatively detect GMO fragments from real GMO products.

  16. High sensitivity optical molecular imaging system

    Science.gov (United States)

    An, Yu; Yuan, Gao; Huang, Chao; Jiang, Shixin; Zhang, Peng; Wang, Kun; Tian, Jie

    2018-02-01

    Optical Molecular Imaging (OMI) has the advantages of high sensitivity, low cost and ease of use. By labeling the regions of interest with fluorescent or bioluminescence probes, OMI can noninvasively obtain the distribution of the probes in vivo, which play the key role in cancer research, pharmacokinetics and other biological studies. In preclinical and clinical application, the image depth, resolution and sensitivity are the key factors for researchers to use OMI. In this paper, we report a high sensitivity optical molecular imaging system developed by our group, which can improve the imaging depth in phantom to nearly 5cm, high resolution at 2cm depth, and high image sensitivity. To validate the performance of the system, special designed phantom experiments and weak light detection experiment were implemented. The results shows that cooperated with high performance electron-multiplying charge coupled device (EMCCD) camera, precision design of light path system and high efficient image techniques, our OMI system can simultaneously collect the light-emitted signals generated by fluorescence molecular imaging, bioluminescence imaging, Cherenkov luminance and other optical imaging modality, and observe the internal distribution of light-emitting agents fast and accurately.

  17. Development of a reagentless electrochemiluminescent electrode for flow injection analysis using copolymerised luminol/aniline on nano-TiO2 functionalised indium-tin oxide glass.

    Science.gov (United States)

    Liu, Chao; Wei, Xiuhua; Tu, Yifeng

    2013-07-15

    In this study, a nano-structured copolymer of luminol/aniline (PLA) was deposited onto nano-TiO2-functionalised indium tin oxide (ITO)-coated glass by electrochemical polymerisation using cyclic voltammetry (CV). The resulting reagentless electrochemiluminescent (ECL) electrode (ECLode) can be used for flow injection analysis (FIA). The properties of the ECLode were characterised by CV, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM). The ECLode has high background ECL emission as well as excellent stability and reproducibility, and yielding sensitive response towards target analytes. The ECL emissions of the ECLode were 50 times higher than PLA/ITO, and 500 times higher than polyluminol (PL)/ITO. The ECLode showed sensitive responses to reactive oxygen species (ROSs), permitting its application for determination of antioxidants by quenching. Under optimised conditions, an absolute detection limit of 69.9 pg was obtained for resveratrol, comparable to the highest levels of sensitivity achieved by other methods. Thus, the gross antioxidant content of red wine was determined, with satisfactory recoveries between 87.6% and 108.3%. These results suggest a bright future for the use of the ECLode for single-channel FIA due to its high sensitivity, accuracy and reproducibility. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Heterogeneous catalysis in highly sensitive microreactors

    DEFF Research Database (Denmark)

    Olsen, Jakob Lind

    This thesis present a highly sensitive silicon microreactor and examples of its use in studying catalysis. The experimental setup built for gas handling and temperature control for the microreactor is described. The implementation of LabVIEW interfacing for all the experimental parts makes...

  19. Aluminum nanocantilevers for high sensitivity mass sensors

    DEFF Research Database (Denmark)

    Davis, Zachary James; Boisen, Anja

    2005-01-01

    We have fabricated Al nanocantilevers using a simple, one mask contact UV lithography technique with lateral and vertical dimensions under 500 and 100 nm, respectively. These devices are demonstrated as highly sensitive mass sensors by measuring their dynamic properties. Furthermore, it is shown ...

  20. Development of an in situ magnetic beads based RT-PCR method for electrochemiluminescent detection of rotavirus

    Science.gov (United States)

    Zhan, Fangfang; Zhou, Xiaoming

    2012-12-01

    Rotaviruses are double-stranded RNA viruses belonging to the family of enteric pathogens. It is a major cause of diarrhoeal disease in infants and young children worldwide. Consequently, rapid and accurate detection of rotaviruses is of great importance in controlling and preventing food- and waterborne diseases and outbreaks. Reverse transcription-polymerase chain reaction (RT-PCR) is a reliable method that possesses high specificity and sensitivity. It has been widely used to detection of viruses. Electrochemiluminescence (ECL) can be considered as an important and powerful tool in analytical and clinical application with high sensitivity, excellent specificity, and low cost. Here we have developed a method for the detection of rotavirus by combining in situ magnetic beads (MBs) based RT-PCR with ECL. RT of rotavirus RNA was carried out in a traditional way and the resulting cDNA was directly amplified on MBs. Forward primers were covalently bounded to MBs and reverse primers were labeled with tris-(2, 2'-bipyridyl) ruthenium (TBR). During the PCR cycling, the TBR labeled products were directly loaded and enriched on the surface of MBs. Then the MBs-TBR complexes could be analyzed by a magnetic ECL platform without any post-modification or post-incubation which avoid some laborious manual operations and achieve rapid yet sensitive detection. In this study, rotavirus from fecal specimens was successfully detected within 2 h, and the limit of detection was estimated to be 104copies/μL. This novel in situ MBs based RT-PCR with ECL detection method can be used for pathogen detection in food safety field and clinical diagnosis.

  1. Single photon detector with high polarization sensitivity.

    Science.gov (United States)

    Guo, Qi; Li, Hao; You, LiXing; Zhang, WeiJun; Zhang, Lu; Wang, Zhen; Xie, XiaoMing; Qi, Ming

    2015-04-15

    Polarization is one of the key parameters of light. Most optical detectors are intensity detectors that are insensitive to the polarization of light. A superconducting nanowire single photon detector (SNSPD) is naturally sensitive to polarization due to its nanowire structure. Previous studies focused on producing a polarization-insensitive SNSPD. In this study, by adjusting the width and pitch of the nanowire, we systematically investigate the preparation of an SNSPD with high polarization sensitivity. Subsequently, an SNSPD with a system detection efficiency of 12% and a polarization extinction ratio of 22 was successfully prepared.

  2. Highly sensitive microcalorimeters for radiation research

    International Nuclear Information System (INIS)

    Avaev, V.N.; Demchuk, B.N.; Ioffe, L.A.; Efimov, E.P.

    1984-01-01

    Calorimetry is used in research at various types of nuclear-physics installations to obtain information on the quantitative and qualitative composition of ionizing radiation in a reactor core and in the surrounding layers of the biological shield. In this paper, the authors examine the characteristics of highly sensitive microcalorimeters with modular semiconductor heat pickups designed for operation in reactor channels. The microcalorimeters have a thin-walled aluminum housing on whose inner surface modular heat pickups are placed radially as shown here. The results of measurements of the temperature dependence of the sensitivity of the microcalorimeters are shown. The results of measuring the sensitivity of a PMK-2 microcalorimeter assembly as a function of integrated neutron flux for three energy intervals and the adsorbed gamma energy are shown. In order to study specimens with different shapes and sizes, microcalorimeters with chambers in the form of cylinders and a parallelepiped were built and tested

  3. High blood pressure and visual sensitivity

    Science.gov (United States)

    Eisner, Alvin; Samples, John R.

    2003-09-01

    The study had two main purposes: (1) to determine whether the foveal visual sensitivities of people treated for high blood pressure (vascular hypertension) differ from the sensitivities of people who have not been diagnosed with high blood pressure and (2) to understand how visual adaptation is related to standard measures of systemic cardiovascular function. Two groups of middle-aged subjects-hypertensive and normotensive-were examined with a series of test/background stimulus combinations. All subjects met rigorous inclusion criteria for excellent ocular health. Although the visual sensitivities of the two subject groups overlapped extensively, the age-related rate of sensitivity loss was, for some measures, greater for the hypertensive subjects, possibly because of adaptation differences between the two groups. Overall, the degree of steady-state sensitivity loss resulting from an increase of background illuminance (for 580-nm backgrounds) was slightly less for the hypertensive subjects. Among normotensive subjects, the ability of a bright (3.8-log-td), long-wavelength (640-nm) adapting background to selectively suppress the flicker response of long-wavelength-sensitive (LWS) cones was related inversely to the ratio of mean arterial blood pressure to heart rate. The degree of selective suppression was also related to heart rate alone, and there was evidence that short-term changes of cardiovascular response were important. The results suggest that (1) vascular hypertension, or possibly its treatment, subtly affects visual function even in the absence of eye disease and (2) changes in blood flow affect retinal light-adaptation processes involved in the selective suppression of the flicker response from LWS cones caused by bright, long-wavelength backgrounds.

  4. Aptamer-Based electrochemiluminescent detection of MCF-7 cancer cells based on carbon quantum dots coated mesoporous silica nanoparticles

    International Nuclear Information System (INIS)

    Su, Min; Liu, Heng; Ge, Lei; Wang, Yanhu; Ge, Shenguang; Yu, Jinghua; Yan, Mei

    2014-01-01

    Graphical abstract: - Highlights: • Aptamers have many advantages over antibodies, such as low molecular weight, easy but reproducible production and low cost. • Mesoporous silica nanoparticles (MSNs) were prepared to load more CQDs for signal amplification which has a large surface area and high pore volume, ordered porous channels, a uniform and tunable pore structure, and a great diversity in surface functionalization • 3D-GR@AuNPs was prepared as biointerface for the immobilization of cancer cells due to their good biological compatibility, excellent conductivity and large surface area. • This new aptasensor may be quite promising, with potential broad applications in cancer early diagnosis due to the excellent analytical performance. - Abstract: In this work, we developed a novel electrochemiluminescence (ECL) platform for ultrasensitive and selective detection of MCF-7 cancer cells. To construct the platform, three-dimensional macroporous AuNPs@graphene complex was prepared through freeze drying process to modify glassy carbon electrode, which provided an effective matrix for concanavalin A to capture cancer cells due to its high surface area-to-weight ratio and excellent mechanical properties. The carbon quantum dots (CQDs) coated mesoporous silica nanoparticles were used as excellent ECL tracers due to their low cytotoxicity and good biocompatibility. Then, the prepared tracers were conjugated with mucin1 aptamer to specifically bind mucin1 on cancer cells with high stability and bioactivity. Structure characterization was obtained by means of transmission electron microscopy and scanning electron microscopy images. The proposed method showed a good analytical performance for the detection of MCF-7 cancer cells ranging from 500 to 2 × 10 7 cells·mL −1 with a detection limit of 230 cells mL −1 . The as-proposed device has the advantages of high sensitivity, nice specificity, and good stability and could offer great promise for sensitive

  5. A electrochemiluminescence aptasensor for detection of thrombin incorporating the capture aptamer labeled with gold nanoparticles immobilized onto the thio-silanized ITO electrode

    International Nuclear Information System (INIS)

    Fang Lanyun; Lue Zhaozi; Wei Hui; Wang Erkang

    2008-01-01

    A novel electrochemiluminescence (ECL) aptasensor was proposed for sensitive and cost-effective detection of the target thrombin adopted an aptamer-based sandwich format. To detect thrombin, capture aptamers labeled with gold nanoparticles (AuNPs) were first immobilized onto the thio-silanized ITO electrode surface through strong Au-S bonds. After catching the target thrombin, signal aptamers tagged with ECL labels were attached to the assembled electrode surface. As a result, an AuNPs-capture-aptamer/thrombin/ECL-tagged-signal-aptamer sandwich type was formed. Treating the resulting electrode surface with tri-n-propylamine (TPA) and applying a swept potential to the electrode, ECL response was generated which realized the detection of target protein. Spectroscopy and electrochemical impedance techniques were used to characterize and confirm the fabrication of the ECL aptasensor. AuNPs amplification and smart sensor fabrication art were implemented for the sensitive and cost-effective detection purpose. Signal-to-dose curve excellently followed a sandwich format equation and could be used to quantify the protein, and the detection limit was estimated to be 10 nM. Other forms of thrombin such as β- and γ-thrombins had negligible response, which indicated a high specificity of α-thrombin detection. The aptasensor opened up new fields of aptamer applications in ECL domain, a highly sensitive technique, and had a promising perspective to be applied in microarray analysis

  6. Low Cost, Low Power, High Sensitivity Magnetometer

    Science.gov (United States)

    2008-12-01

    which are used to measure the small magnetic signals from brain. Other types of vector magnetometers are fluxgate , coil based, and magnetoresistance...concentrator with the magnetometer currently used in Army multimodal sensor systems, the Brown fluxgate . One sees the MEMS fluxgate magnetometer is...Guedes, A.; et al., 2008: Hybrid - LOW COST, LOW POWER, HIGH SENSITIVITY MAGNETOMETER A.S. Edelstein*, James E. Burnette, Greg A. Fischer, M.G

  7. Label-free and ultrasensitive electrochemiluminescence detection of microRNA based on long-range self-assembled DNA nanostructures

    International Nuclear Information System (INIS)

    Liu, Ting; Chen, Xian; Hong, Cheng-Yi; Xu, Xiao-Ping; Yang, Huang-Hao

    2014-01-01

    Electrochemiluminescence (ECL) integrates the advantages of electrochemical detection and chemiluminescent techniques. The method has received particular attention because it is highly sensitive and selective, has a wide linear range but low reagent costs. The use of nanomaterials with their unique physical and chemical properties has led to new kinds of biosensors that exhibit high sensitivity and stability. Compared to other nanomaterials, DNA nanostructures are more biocompatible, more hydrophilic, and thus less prone to nonspecific adsorption onto the electrode surface. We describe here a label-free and ultrasensitive ECL biosensor for detecting a cancer-associated microRNA at a femtomolar level. We have designed two auxiliary probes that cause the formation of a long-range self-assembly in the form of a μm-long 1-dimensional DNA concatamer. These can be used as carriers for signal amplification. The intercalation of the ECL probe Ru(phen) 3 2+ into the grooves of the concatamers leads to a substantial increase in ECL intensity. This amplified sensor shows high selectivity for discriminating complementary target and other mismatched RNAs. The biosensor enables the quantification of the expression of microRNA-21 in MCF-7 cells. It also displays very low limits of detection and provides an alternative approach for the detection of RNA or DNA detection in diagnostics and gene analysis. (author)

  8. Review of high-sensitivity Radon studies

    Science.gov (United States)

    Wojcik, M.; Zuzel, G.; Simgen, H.

    2017-10-01

    A challenge in many present cutting-edge particle physics experiments is the stringent requirements in terms of radioactive background. In peculiar, the prevention of Radon, a radioactive noble gas, which occurs from ambient air and it is also released by emanation from the omnipresent progenitor Radium. In this paper we review various high-sensitivity Radon detection techniques and approaches, applied in the experiments looking for rare nuclear processes happening at low energies. They allow to identify, quantitatively measure and finally suppress the numerous sources of Radon in the detectors’ components and plants.

  9. An ultrasensitive label-free electrochemiluminescent immunosensor for measuring Cry1Ab level and genetically modified crops content.

    Science.gov (United States)

    Gao, Hongfei; Wen, Luke; Wu, Yuhua; Fu, Zhifeng; Wu, Gang

    2017-11-15

    The development of genetically modified (GM) insect-resistant crops has aroused great public concern about the risks on the eco-environment resulting from a release of toxic Cry proteins (such as Cry1Ab) to the soil. Therefore, it is of crucial importance to measure the Cry proteins level and the GM crops content. Here, we have tested for the first time a method that uses novel carbon nanospheres (CNPs) label-free electrochemiluminescent (ECL) immunosensor for the ultrasensitive quantification of Cry1Ab and GM crops. In this work, novel CNPs were prepared from printer toner with a very facile approach, and linked with anti-Cry1Ab antibodies to modify a golden working electrode. The immunoreaction between Cry1Ab and its antibody formed an immunocomplex on the bioreceptor region of the sensor, which inhibited electron transfer between the electrode surface and the ECL substance, leading to a decrease of ECL response. Under the optimal conditions, the fabricated label-free ECL immunosensor determined Cry1Ab down to 3.0pgmL -1 within a linear range of 0.010-1.0ngmL -1 , showing significant improvement of sensitivity than that of most previous reports. Meanwhile, the proposed method was successfully applied for GM rice BT63 and GM maize MON810 detections down to 0.010% and 0.020%, respectively. Due to its outstanding advantages such as high sensitivity, ideal selectivity, simple fabrication, rapid detection, and low cost, the developed method can be considered as a powerful and pioneering tool for GM crops detection. Its use can also be extended to other toxin protein sensing in foods. Copyright © 2017. Published by Elsevier B.V.

  10. High sensitivity troponin and valvular heart disease.

    Science.gov (United States)

    McCarthy, Cian P; Donnellan, Eoin; Phelan, Dermot; Griffin, Brian P; Enriquez-Sarano, Maurice; McEvoy, John W

    2017-07-01

    Blood-based biomarkers have been extensively studied in a range of cardiovascular diseases and have established utility in routine clinical care, most notably in the diagnosis of acute coronary syndrome (e.g., troponin) and the management of heart failure (e.g., brain-natriuretic peptide). The role of biomarkers is less well established in the management of valvular heart disease (VHD), in which the optimal timing of surgical intervention is often challenging. One promising biomarker that has been the subject of a number of recent VHD research studies is high sensitivity troponin (hs-cTn). Novel high-sensitivity assays can detect subclinical myocardial damage in asymptomatic individuals. Thus, hs-cTn may have utility in the assessment of asymptomatic patients with severe VHD who do not have a clear traditional indication for surgical intervention. In this state-of-the-art review, we examine the current evidence for hs-cTn as a potential biomarker in the most commonly encountered VHD conditions, aortic stenosis and mitral regurgitation. This review provides a synopsis of early evidence indicating that hs-cTn has promise as a biomarker in VHD. However, the impact of its measurement on clinical practice and VHD outcomes needs to be further assessed in prospective studies before routine clinical use becomes a reality. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Highly sensitive high resolution Raman spectroscopy using resonant ionization methods

    International Nuclear Information System (INIS)

    Owyoung, A.; Esherick, P.

    1984-05-01

    In recent years, the introduction of stimulated Raman methods has offered orders of magnitude improvement in spectral resolving power for gas phase Raman studies. Nevertheless, the inherent weakness of the Raman process suggests the need for significantly more sensitive techniques in Raman spectroscopy. In this we describe a new approach to this problem. Our new technique, which we call ionization-detected stimulated Raman spectroscopy (IDSRS), combines high-resolution SRS with highly-sensitive resonant laser ionization to achieve an increase in sensitivity of over three orders of magnitude. The excitation/detection process involves three sequential steps: (1) population of a vibrationally excited state via stimulated Raman pumping; (2) selective ionization of the vibrationally excited molecule with a tunable uv source; and (3) collection of the ionized species at biased electrodes where they are detected as current in an external circuit

  12. Determination of sibutramine with a new sensor based on luminol electrochemiluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Wang Shaowei [Shandong Provincial Key Laboratory of Fluorine Chemistry and Chemical Materials, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022 (China); Yu Jinghua, E-mail: wangshaowei119@hotmail.co [Shandong Provincial Key Laboratory of Fluorine Chemistry and Chemical Materials, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022 (China); Wan Fuwei; Ge Shenguang; Yan Mei; Zhang Meng [Shandong Provincial Key Laboratory of Fluorine Chemistry and Chemical Materials, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022 (China)

    2011-07-15

    A flow injection electrochemiluminescence (FI-ECL) analysis method for the determination of sibutramine in the presence of luminol was studied under conventional cyclic voltammetry in alkaline Na{sub 2}CO{sub 3}-NaHCO{sub 3} buffer solution (pH 8.0-12.0). This method is based on the enhanced ECL of luminol-sibutramine. Meanwhile, in order to overcome the drawbacks of conventional cells, a FI cell was designed, which is reusable and has a great improvement in sensitivity and selectivity for ECL analysis. Under the optimal experimental conditions, the enhanced ECL intensity was linearly related to the concentration of sibutramine in the range 1.0x10{sup -8}-1.0x10{sup -6} g mL{sup -1} with a detection limit of 2.48x10{sup -9} g mL{sup -1} and a correlation coefficient (R) of 0.9995. The relative standard deviation (RSD) for 1.0x10{sup -7} g mL{sup -1} samples was 2.1% (n=11). The possible mechanism discussed. The proposed FI-ECL method has been successfully applied to the determination of sibutramine in diet pill samples. - Highlights: {yields} An electrochemiluminescence (ECL) system was studied to determine sibutramine. {yields} A flow injection cell was made to overcome the drawbacks of the conventional ones. {yields} The system was based on the enhanced ECL of luminol-sibutramine. {yields} The system can be satisfactorily applied to determine sibutramine in diet pills.

  13. A novel solid-state electrochemiluminescence quenching sensor for detection of aniline based on luminescent composite nanofibers

    International Nuclear Information System (INIS)

    Wang, Xiaoying; Yang, Yu; Gao, Huiwen

    2014-01-01

    A novel solid-state electrochemiluminescence (ECL) quenching sensor based on the luminescent composite nanofibers for detection of aniline has been developed. The gold nanoparticles (AuNPs) and Ruthenium (II) tris-(bipyridine) (Ru(bpy) 3 2+ ) doped nylon 6 (PA6) luminescent composite nanofibers (Ru–AuNPs–PA6) were successfully deposited to the bare glassy carbon (GC) electrode by a one-step electrospinning technique. The Ru–AuNPs–PA6 nanofibers maintained the photoelectric properties of the Ru(bpy) 3 2+ ions completely and exhibited excellent ECL behaviors. A high quenching effect on the ECL signal of the Ru–AuNPs–PA6/C 2 O 4 2− system was obtained with the presence of low concentration aniline compounds. The potential of analytical application was explored by use of the inhibited ECL. The quenching efficiencies of the five kinds of aniline compounds were compared by monitoring the aniline-dependent ECL intensity change. The magnitude of quenching depended linearly upon the concentration of aniline in the investigated concentration range of 10–10 µM. The detection limit for aniline is 5.0 nM, which is comparable or better than that in the reported assays. The solid-state ECL quenching sensor exhibited high sensitivity and good stability. This study may provide new insight into the design of advanced electrospun nanofibers-based ECL sensors for detection and analysis of a variety of active molecules. - Highlights: • The Ru–AuNPs–PA6 nanofibers were first prepared by one-step electrospinning technique. • The Ru–AuNPs–PA6 nanofibers exhibited excellent ECL behaviors on GC electrodes. • It is the first solid-state ECL sensor based on nanofibers for aniline detection. • The quenching efficiencies of the five kinds of aniline compounds were compared. • The strategy could be extended to develop various nanofibers-based ECL sensors

  14. CALDER: High-sensitivity cryogenic light detectors

    International Nuclear Information System (INIS)

    Casali, N.; Bellini, F.; Cardani, L.

    2017-01-01

    The current bolometric experiments searching for rare processes such as neutrinoless double-beta decay or dark matter interaction demand for cryogenic light detectors with high sensitivity, large active area and excellent scalability and radio-purity in order to reduce their background budget. The CALDER project aims to develop such kind of light detectors implementing phonon-mediated Kinetic Inductance Detectors (KIDs). The goal for this project is the realization of a 5 × 5 cm"2 light detector working between 10 and 100mK with a baseline resolution RMS below 20 eV. In this work the characteristics and the performances of the prototype detectors developed in the first project phase will be shown.

  15. High sensitive radiation detector for radiology dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Valente, M.; Malano, F. [Instituto de Fisica Enrique Gaviola, Oficina 102 FaMAF - UNC, Av. Luis Medina Allende, Ciudad Universitaria, 5000 Cordoba (Argentina); Molina, W.; Vedelago, J., E-mail: valente@famac.unc.edu.ar [Laboratorio de Investigaciones e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Laboratorio 448 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina)

    2014-08-15

    Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, dose rate recorded and incident direction independence as well as linear dose response. This work presents the development and characterization of a novel Fricke gel system, based on modified chemical compositions making possible its application in clinical radiology. Properties of standard Fricke gel dosimeter for high dose levels are used as starting point and suitable chemical modifications are introduced and carefully investigated in order to attain high resolution for low dose ranges, like those corresponding to radiology interventions. The developed Fricke gel radiation dosimeter system achieves the expected typical dose dependency, actually showing linear response in the dose range from 20 up to 4000 mGy. Systematic investigations including several chemical compositions are carried out in order to obtain a good enough dosimeter response for low dose levels. A suitable composition among those studied is selected as a good candidate for low dose level radiation dosimetry consisting on a modified Fricke solution fixed to a gel matrix containing benzoic acid along with sulfuric acid, ferrous sulfate, xylenol orange and ultra-pure reactive grade water. Dosimeter samples are prepared in standard vials for its in phantom irradiation and further characterization by spectrophotometry measuring visible light transmission and absorbance before and after irradiation. Samples are irradiated by typical kV X-ray tubes and calibrated Farmer type ionization chamber is used as reference to measure dose rates inside phantoms in at vials locations. Once sensitive material composition is already optimized, dose-response curves show significant improvement regarding overall sensitivity for low dose levels. According to

  16. High sensitivity amplifier/discriminator for PWC's

    International Nuclear Information System (INIS)

    Hansen, S.

    1983-01-01

    The facility support group at Fermilab is designing and building a general purpose beam chamber for use in several locations at the laboratory. This pwc has 128 wires per plane spaced 1 mm apart. An initial production of 25 signal planes is anticipated. In proportional chambers, the size of the signal depends exponentially on the charge stored per unit of length along the anode wire. As the wire spacing decreases, the capacitance per unit length decreases, thereby requiring increased applied voltage to restore the necessary charge per unit length. In practical terms, this phenomenon is responsible for difficulties in constructing chambers with less than 2 mm wire spacing. 1 mm chambers, therefore, are frequently operated very near to their breakdown point and/or a high gain gas containing organic compounds such as magic gas is used. This argon/iso-butane mixture has three drawbacks: it is explosive when exposed to the air, it leaves a residue on the wires after extended use and is costly. An amplifier with higher sensitivity would reduce the problems associated with operating chambers with small wire spacings and allow them to be run a safe margin below their breakdown voltage even with an inorganic gas mixture such as argon/CO2, this eliminating the need to use magic gas. Described here is a low cost amplifier with a usable threshold of less than 0.5 μA. Data on the performance of this amplifier/discriminator in operation on a prototype beam chamber are given. This data shows the advantages of the high sensitivity of this design

  17. High sensitive radiation detector for radiology dosimetry

    International Nuclear Information System (INIS)

    Valente, M.; Malano, F.; Molina, W.; Vedelago, J.

    2014-08-01

    Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, dose rate recorded and incident direction independence as well as linear dose response. This work presents the development and characterization of a novel Fricke gel system, based on modified chemical compositions making possible its application in clinical radiology. Properties of standard Fricke gel dosimeter for high dose levels are used as starting point and suitable chemical modifications are introduced and carefully investigated in order to attain high resolution for low dose ranges, like those corresponding to radiology interventions. The developed Fricke gel radiation dosimeter system achieves the expected typical dose dependency, actually showing linear response in the dose range from 20 up to 4000 mGy. Systematic investigations including several chemical compositions are carried out in order to obtain a good enough dosimeter response for low dose levels. A suitable composition among those studied is selected as a good candidate for low dose level radiation dosimetry consisting on a modified Fricke solution fixed to a gel matrix containing benzoic acid along with sulfuric acid, ferrous sulfate, xylenol orange and ultra-pure reactive grade water. Dosimeter samples are prepared in standard vials for its in phantom irradiation and further characterization by spectrophotometry measuring visible light transmission and absorbance before and after irradiation. Samples are irradiated by typical kV X-ray tubes and calibrated Farmer type ionization chamber is used as reference to measure dose rates inside phantoms in at vials locations. Once sensitive material composition is already optimized, dose-response curves show significant improvement regarding overall sensitivity for low dose levels. According to

  18. High sensitivity thermal sensors on insulating diamond

    Energy Technology Data Exchange (ETDEWEB)

    Job, R. [Fernuniversitaet Hagen (Gesamthochschule) (Germany). Electron. Devices; Denisenko, A.V. [Fernuniversitaet Hagen (Gesamthochschule) (Germany). Electron. Devices; Zaitsev, A.M. [Fernuniversitaet Hagen (Gesamthochschule) (Germany). Electron. Devices; Melnikov, A.A. [Belarussian State Univ., Minsk (Belarus). HEII and FD; Werner, M. [VDI/VDE-IT, Teltow (Germany); Fahrner, W.R. [Fernuniversitaet Hagen (Gesamthochschule) (Germany). Electron. Devices

    1996-12-15

    Diamond is a promising material to develop sensors for applications in harsh environments. To increase the sensitivity of diamond temperature sensors the effect of thermionic hole emission (TE) over an energetic barrier formed in the interface between highly boron-doped p-type and intrinsic insulating diamond areas has been suggested. To study the TE of holes a p-i-p diode has been fabricated and analyzed by electrical measurements in the temperature range between 300 K and 700 K. The experimental results have been compared with numerical simulations of its electrical characteristics. Based on a model of the thermionic emission of carriers into an insulator it has been suggested that the temperature sensitivity of the p-i-p diode on diamond is strongly affected by the re-emission of holes from a group of donor-like traps located at a level of 0.7-1.0 eV above the valence band. The mechanism of thermal activation of the current includes a spatial redistribution of the potential, which results in the TE regime from a decrease of the immobilized charge of the ionized traps within the i-zone of the diode and the correspondent lowering of the forward biased barrier. The characteristics of the p-i-p diode were studied with regard to temperature sensor applications. The temperature coefficient of resistance (TCR=-0.05 K{sup -1}) for temperatures above 600 K is about four times larger than the maximal attainable TCR for conventional boron-doped diamond resistors. (orig.)

  19. Transportable high sensitivity small sample radiometric calorimeter

    International Nuclear Information System (INIS)

    Wetzel, J.R.; Biddle, R.S.; Cordova, B.S.; Sampson, T.E.; Dye, H.R.; McDow, J.G.

    1998-01-01

    A new small-sample, high-sensitivity transportable radiometric calorimeter, which can be operated in different modes, contains an electrical calibration method, and can be used to develop secondary standards, will be described in this presentation. The data taken from preliminary tests will be presented to indicate the precision and accuracy of the instrument. The calorimeter and temperature-controlled bath, at present, require only a 30-in. by 20-in. tabletop area. The calorimeter is operated from a laptop computer system using unique measurement module capable of monitoring all necessary calorimeter signals. The calorimeter can be operated in the normal calorimeter equilibration mode, as a comparison instrument, using twin chambers and an external electrical calibration method. The sample chamber is 0.75 in (1.9 cm) in diameter by 2.5 in. (6.35 cm) long. This size will accommodate most 238 Pu heat standards manufactured in the past. The power range runs from 0.001 W to <20 W. The high end is only limited by sample size

  20. Electrochemiluminescence immunosensor for ultrasensitive detection of biomarker using Ru(bpy){sub 3}{sup 2+}-encapsulated silica nanosphere labels

    Energy Technology Data Exchange (ETDEWEB)

    Qian Jing [School of Chemistry and Chemical Engineering, Southeast University, Nanjing, 211189 (China); Zhou Zhenxian [Nanjing Second Hospital, Nanjing, 210003 (China); Cao Xiaodong [School of Chemistry and Chemical Engineering, Southeast University, Nanjing, 211189 (China); Liu Songqin, E-mail: liusq@seu.edu.cn [School of Chemistry and Chemical Engineering, Southeast University, Nanjing, 211189 (China)

    2010-04-14

    Here, we describe a new approach for electrochemiluminescence (ECL) assay with Ru(bpy){sub 3}{sup 2+}-encapsulated silica nanoparticle (SiO{sub 2}-Ru) as labels. A water-in-oil (W/O) microemulsion method was employed for one-pot synthesis of SiO{sub 2}-Ru nanoparticles. The as-synthesized SiO{sub 2}-Ru nanoparticles have a narrow size distribution, which allows reproducible loading of Ru(bpy){sub 3}{sup 2+} inside the silica shell and of {alpha}-fetoprotein antibody (anti-AFP), a model antibody, on the silica surface with glutaraldehyde as linkage. The silica shell effectively prevents leakage of Ru(bpy){sub 3}{sup 2+} into the aqueous solution due to strong electrostatic interaction between the positively charged Ru(bpy){sub 3}{sup 2+} and the negatively charged surface of silica. The porous structure of silica shell allowed the ion to move easily through the pore to exchange energy/electrons with the entrapped Ru(bpy){sub 3}{sup 2+}. The as-synthesized SiO{sub 2}-Ru can be used as a label for ultrasensitive detection of biomarkers through a sandwiched immunoassay process. The calibration range of AFP concentration was 0.05-30 ng mL{sup -1} with linear relation from 0.05 to 20 ng mL{sup -1} and a detection limit of 0.035 ng mL{sup -1} at 3{sigma}. The resulting immunosensors possess high sensitivity and good analytical performance.

  1. Electrochemiluminescence immunosensor for ultrasensitive detection of biomarker using Ru(bpy)(3)(2+)-encapsulated silica nanosphere labels.

    Science.gov (United States)

    Qian, Jing; Zhou, Zhenxian; Cao, Xiaodong; Liu, Songqin

    2010-04-14

    Here, we describe a new approach for electrochemiluminescence (ECL) assay with Ru(bpy)(3)(2+)-encapsulated silica nanoparticle (SiO(2)@Ru) as labels. A water-in-oil (W/O) microemulsion method was employed for one-pot synthesis of SiO(2)@Ru nanoparticles. The as-synthesized SiO(2)@Ru nanoparticles have a narrow size distribution, which allows reproducible loading of Ru(bpy)(3)(2+) inside the silica shell and of alpha-fetoprotein antibody (anti-AFP), a model antibody, on the silica surface with glutaraldehyde as linkage. The silica shell effectively prevents leakage of Ru(bpy)(3)(2+) into the aqueous solution due to strong electrostatic interaction between the positively charged Ru(bpy)(3)(2+) and the negatively charged surface of silica. The porous structure of silica shell allowed the ion to move easily through the pore to exchange energy/electrons with the entrapped Ru(bpy)(3)(2+). The as-synthesized SiO(2)@Ru can be used as a label for ultrasensitive detection of biomarkers through a sandwiched immunoassay process. The calibration range of AFP concentration was 0.05-30 ng mL(-1) with linear relation from 0.05 to 20 ng mL(-1) and a detection limit of 0.035 ng mL(-1) at 3sigma. The resulting immunosensors possess high sensitivity and good analytical performance. Copyright 2010 Elsevier B.V. All rights reserved.

  2. Chemically Regulated ROS Generation from Gold Nanoparticles for Enzyme-Free Electrochemiluminescent Immunosensing.

    Science.gov (United States)

    Higashi, Yui; Mazumder, Joyotu; Yoshikawa, Hiroyuki; Saito, Masato; Tamiya, Eiichi

    2018-04-17

    In the present work, we report on an enzyme-free electrochemiluminescent (ECL) immunosensing scheme utilizing the catalytic generation of reactive oxygen species (ROS) from gold nanoparticles (AuNPs) (diameter ≥5 nm) dispersed in aqueous solutions of trishydroxymethylaminomethane (Tris). First, to examine this catalytic pathway in detail, the effects of various factors such as the AuNP size and concentration, dispersant type and concentration, and dissolved oxygen were investigated using the electrochemiluminescence (ECL) of luminol. It was found that the catalytic generation of ROS from AuNPs can be regulated chemically by altering conditions such as the type, concentration, and pH of the solution that the AuNPs are dispersed in. Under the best conditions studied in this work, the AuNPs displayed high catalytic activity toward ROS generation, with an estimated apparent turnover number per AuNP of 0.1 s -1 , comparable to those of several common peroxide-producing enzymes. Following these studies, this phenomenon was applied to develop a one-step enzyme-free ECL immunosensor based on sandwiching the target analyte using antibody-conjugated magnetic beads (MB) and AuNPs. Using IgA as a model analyte, the developed immunosensor was able to detect the target in the range of 1 ng/mL to 10 μg/mL, with the lower detection limit being comparable to those of commercial assays for the same target. Altering the antibodies used to modify the MB and AuNPs could further improve the detection limit as well as expand the applicability of this immunoassay to the detection of other analytes.

  3. Highly sensitive detection of a current ripple

    International Nuclear Information System (INIS)

    Aoki, Takashi; Gushiken, Tutomu; Nishikigouri, Kazutaka; Kumada, Masayuki.

    1996-01-01

    In the HIMAC, there are six thyristor-controlled power sources for driving two synchrotrons. These power sources are the three-output terminal power sources which are equipped with positive output, negative output and neutral point for the common mode countermeasures. As electromagnet circuits are connected to the three-output terminal power sources, those are three-line type. In the inside of the power source circuits controlled by thyristors, there is the oscillation peculiar to the power sources, and the variation of voltage induces current spikes. This time, in order to assess the results of the common mode countermeasures in the power source and electromagnet circuits, as one method of cross-check, it is considered that since electromagnet current flows being divided to the bridging resistance and the coil, if attention is paid to the current on bridging resistance side, the ripple components of common mode and normal mode can be detected with high sensitivity, and this was verified. The present state of heightening the performance of synchrotron power sources is explained. The cross-check of the method of assessing the performance of electromagnet power sources is reported. The method of measuring ripple current and the results of the measurement are reported. (K.I.)

  4. Development of high sensitivity radon detectors

    CERN Document Server

    Takeuchi, Y; Kajita, T; Tasaka, S; Hori, H; Nemoto, M; Okazawa, H

    1999-01-01

    High sensitivity detectors for radon in air and in water have been developed. We use electrostatic collection and a PIN photodiode for these detectors. Calibration systems have been also constructed to obtain collection factors. As a result of the calibration study, the absolute humidity dependence of the radon detector for air is clearly observed in the region less than about 1.6 g/m sup 3. The calibration factors of the radon detector for air are 2.2+-0.2 (counts/day)/(mBq/m sup 3) at 0.08 g/m sup 3 and 0.86+-0.06 (counts/day)/(mBq/m sup 3) at 11 g/m sup 3. The calibration factor of the radon detector for water is 3.6+-0.5 (counts/day)/(mBq/m sup 3). The background level of the radon detector for air is 2.4+-1.3 counts/day. As a result, one standard deviation excess of the signal above the background of the radon detector for air should be possible for 1.4 mBq/m sup 3 in a one-day measurement at 0.08 g/m sup 3.

  5. Enhanced electrochemiluminescence based on Ru(bpy)₃²⁺-doped silica nanoparticles and graphene composite for analysis of melamine in milk

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Limin [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022 (China); University of the Chinese Academy of Sciences (China); Huang, Jianshe [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022 (China); Yang, Lu; Li, Libo [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022 (China); University of the Chinese Academy of Sciences (China); You, Tianyan, E-mail: youty@ciac.jl.cn [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022 (China)

    2014-05-01

    Highlights: • A sensitive ECL sensor was developed by combining Ru(bpy)₃²⁺-doped silica (Ru(bpy)₃²⁺@SiO₂) nanoparticles with graphene. • The proposed sensor exhibited high sensitivity (~10⁻¹³ M) and wide linear range for melamine. • This method was successfully applied to the detection of melamine in milk. Abstract: A sensitive electrochemiluminescence (ECL) sensor for melamine analysis was fabricated based on Ru(bpy)₃²⁺-doped silica (Ru(bpy)₃²⁺@SiO₂) nanoparticles and graphene composite. Spherical Ru(bpy)₃²⁺@SiO₂ nanoparticles with uniform size about 55 nm were prepared by the reverse microemulsion method. Since per Ru(bpy)₃²⁺@SiO₂ nanoparticle encapsulated a great deal of Ru(bpy)₃²⁺, the ECL intensity has been greatly enhanced, which resulted in high sensitivity. Due to its extraordinary electric conductivity, graphene improved the conductivity and accelerated the electron transfer rate. In addition, graphene could work as electronic channel improving the efficient luminophor amount participating in the ECL reaction, which further enhanced the ECL signal. This proposed sensor was used to melamine analysis and the ECL intensity was proportional to logarithmic melamine concentration range from 1 × 10⁻¹³ M to 1 × 10⁻⁸ M with the detect limit as low as 1 × 10⁻¹³ M. In application to detect melamine in milk, satisfactory recoveries could be obtained, which indicated this sensor having potential application in melamine analysis in real samples.

  6. Electrochemiluminescence behavior of AgNCs and its application in immunosensors based on PANI/PPy-Ag dendrite-modified electrode.

    Science.gov (United States)

    Zhang, Lina; Wang, Yanhu; Shen, Lei; Yu, Jinghua; Ge, Shenguang; Yan, Mei

    2017-07-10

    In this study, hyperbranched polyethyleneimine-protected silver nanoclusters (hPEI-AgNCs) with excellent electrochemiluminescence (ECL) emission in the presence of coreactant K 2 S 2 O 8 were prepared by chemical reduction of silver ions (silver nitrate) coordinated with dendrigraft polymer, and successfully used for the construction of an ECL immunosensor. Polyaniline (PANI)/polypyrrole (PPy)-silver (Ag) dendrites with good electrical conductivity and biocompatibility were electropolymerized on the surface of indium tin oxide (ITO) electrode as carriers. Porous ZnO sphere-loaded hPEI-AgNCs-induced signal amplification strategies were integrated exquisitely and applied sufficiently. Taking carcinoembryonic antigen (CEA) as an example, under optimal conditions, the CEA concentration was determined to be in the range of 10 -3 ng mL -1 -100 ng mL -1 and with a detection limit of 0.4 pg mL -1 using this method; it exhibited excellent selectivity, high stability, and acceptable fabrication reproducibility. It was anticipated that hPEI-AgNCs would have promising applications in green, selective, and sensitive detection of target analytes in the future.

  7. PCR-free quantitative detection of genetically modified organism from raw materials – A novel electrochemiluminescence-based bio-barcode method

    Science.gov (United States)

    Zhu, Debin; Tang, Yabing; Xing, Da; Chen, Wei R.

    2018-01-01

    Bio-barcode assay based on oligonucleotide-modified gold nanoparticles (Au-NPs) provides a PCR-free method for quantitative detection of nucleic acid targets. However, the current bio-barcode assay requires lengthy experimental procedures including the preparation and release of barcode DNA probes from the target-nanoparticle complex, and immobilization and hybridization of the probes for quantification. Herein, we report a novel PCR-free electrochemiluminescence (ECL)-based bio-barcode assay for the quantitative detection of genetically modified organism (GMO) from raw materials. It consists of tris-(2’2’-bipyridyl) ruthenium (TBR)-labele barcode DNA, nucleic acid hybridization using Au-NPs and biotin-labeled probes, and selective capture of the hybridization complex by streptavidin-coated paramagnetic beads. The detection of target DNA is realized by direct measurement of ECL emission of TBR. It can quantitatively detect target nucleic acids with high speed and sensitivity. This method can be used to quantitatively detect GMO fragments from real GMO products. PMID:18386909

  8. Electrochemiluminescent determination of methamphetamine based on tris(2,2'-bipyridine)ruthenium(II) ion-association in organically modified silicate films

    International Nuclear Information System (INIS)

    Yi Changqing; Tao Yin; Wang Bo; Chen Xi

    2005-01-01

    Tetramethoxysilane (TMOS) and dimethyldimethoxysilane (DiMe-DiMOS) were used as co-precursor to immobilize poly(p-styrenesulfonate) (PSS), then tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy) 3 2+ ) was successfully immobilized on a glass carbon electrode via ion-association. The immobilized Ru(bpy) 3 2+ shows good electrochemical and photochemical activities. Electrochemical and electrochemiluminescence (ECL) characterizations of the organically modified silicates (ORMOSILs) modified film electrodes were made by means of cyclic voltammetry and chronocoulometry. The ORMOSIL films were investigated by atomic force microscopy, scanning electrochemical microscope, tunnelling electrochemical microscope, X-ray photoelectron spectroscopy (XPS), UV-vis spectroscopy and fluorescence spectroscopy. XPS in-depth profiles revealed a homogeneous distribution of Ru(bpy) 3 2+ inside the silica thin layers. The modified electrode was used for the ECL determination of methamphetamine (METH) and showed high sensitivity. Detection limit was 2.0 x 10 -7 mol l -1 for METH (S/N = 3) with a linear range from 5.0 x 10 -7 to 1.0 x 10 -3 mol l -1 (R = 0.986). The relative standard deviation (n = 6) was 1.1% for the determination of 1.0 x 10 -5 mol l -1 METH. Furthermore, the Ru(bpy) 3 2+ immobilized modified electrode was applied in the ECL determination of methamphetamine (METH) in scout cases

  9. Electrochemiluminescent determination of methamphetamine based on tris(2,2'-bipyridine)ruthenium(II) ion-association in organically modified silicate films

    Energy Technology Data Exchange (ETDEWEB)

    Yi Changqing [Key Laboratory of Analytical Sciences of Ministry of Education, Department of Chemistry, Xiamen University, Xiamen 361005 (China); Tao Yin [Key Laboratory of Analytical Sciences of Ministry of Education, Department of Chemistry, Xiamen University, Xiamen 361005 (China); Wang Bo [Institute of Criminal Science and Technology of Xiamen, Xiamen 361005 (China); Chen Xi [Key Laboratory of Analytical Sciences of Ministry of Education, Department of Chemistry, Xiamen University, Xiamen 361005 (China)]. E-mail: xichen@xmu.edu.cn

    2005-06-13

    Tetramethoxysilane (TMOS) and dimethyldimethoxysilane (DiMe-DiMOS) were used as co-precursor to immobilize poly(p-styrenesulfonate) (PSS), then tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy){sub 3} {sup 2+}) was successfully immobilized on a glass carbon electrode via ion-association. The immobilized Ru(bpy){sub 3} {sup 2+} shows good electrochemical and photochemical activities. Electrochemical and electrochemiluminescence (ECL) characterizations of the organically modified silicates (ORMOSILs) modified film electrodes were made by means of cyclic voltammetry and chronocoulometry. The ORMOSIL films were investigated by atomic force microscopy, scanning electrochemical microscope, tunnelling electrochemical microscope, X-ray photoelectron spectroscopy (XPS), UV-vis spectroscopy and fluorescence spectroscopy. XPS in-depth profiles revealed a homogeneous distribution of Ru(bpy){sub 3} {sup 2+} inside the silica thin layers. The modified electrode was used for the ECL determination of methamphetamine (METH) and showed high sensitivity. Detection limit was 2.0 x 10{sup -7} mol l{sup -1} for METH (S/N = 3) with a linear range from 5.0 x 10{sup -7} to 1.0 x 10{sup -3} mol l{sup -1} (R = 0.986). The relative standard deviation (n = 6) was 1.1% for the determination of 1.0 x 10{sup -5} mol l{sup -1} METH. Furthermore, the Ru(bpy){sub 3} {sup 2+} immobilized modified electrode was applied in the ECL determination of methamphetamine (METH) in scout cases.

  10. An ultrasensitive electrochemiluminescent immunosensor based on graphene oxide coupled graphite-like carbon nitride and multiwalled carbon nanotubes-gold for the detection of diclofenac.

    Science.gov (United States)

    Hu, Liuyi; Zheng, Jing; Zhao, Kang; Deng, Anping; Li, Jianguo

    2018-03-15

    In this study, a novel competition-type electrochemiluminescent (ECL) immunosensor for detecting diclofenac (DCF) was fabricated with graphene oxide coupled graphite-like carbon nitride (GO-g-C 3 N 4 ) as signal probe for the first time. The ECL intensity of carboxylated g-C 3 N 4 was significantly enhanced after being combined with graphene oxide (GO) which exhibited excellent charge-transport property. The sensing platform was constructed by multiwalled carbon nanotubes and gold nanoparticles (MWCNTs-AuNPs), which not only provided an effective matrix for immobilizing a large amount of coating antigen but also facilitated the electronic transmission rate to enhance the ECL intensity. Based on the synergistic effect of GO-g-C 3 N 4 and MWCNTs-AuNPs composite, the proposed sensor showed high sensitivity, good stability, and wide linearity for the detection of DCF in the range of 0.005-1000ngmL -1 with a detection limit of 1.7pgmL -1 . Furthermore, the developed immunoassay has been applied to real samples with satisfactory results. Therefore, this work provided a promising method for the detection of DCF and other small molecular compounds in the future. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Label-free electrochemiluminescence biosensor for ultrasensitive detection of telomerase activity in HeLa cells based on extension reaction and intercalation of Ru(phen)3 (2.).

    Science.gov (United States)

    Lin, Yue; Yang, Linlin; Yue, Guiyin; Chen, Lifen; Qiu, Bin; Guo, Longhua; Lin, Zhenyu; Chen, Guonan

    2016-10-01

    Telomerase is one of the most common markers of human malignant tumors, such as uterine, stomach, esophageal, breast, colorectal, laryngeal squamous cell, thyroid, bladder, and so on. It is necessary to develop some sensitive but convenient detection methods for telomerase activity determination. In this study, a label-free and ultrasensitive electrochemiluminescence (ECL) biosensor has been fabricated to detect the activity of telomerase extracted from HeLa cells. Thiolated telomerase substrate (TS) primer was immobilized on the gold electrode surface through gold-sulfur (Au-S) interaction and then elongated by telomerase specifically. Then, it was hybridized with complementary DNA to form double-stranded DNA (dsDNA) fragments on the electrode surface, and Ru(phen)3 (2+) has been intercalated into the dsDNA grooves to act as the ECL probe. The enhanced ECL intensity has a linear relationship with the number of HeLa cells in the range of 5∼5000 and with a detection limit of 2 HeLa cells. The proposed ECL biosensor has high specificity to telomerase in the presence of common interferents. The relative standard deviations (RSDs) were HeLa cells. The proposed method provides a convenient approach for telomerase-related cancer screening or diagnosis.

  12. Liquid chromatography with luminol-based electrochemiluminescence detection determination of histamine

    NARCIS (Netherlands)

    Steijger, O.M.; Kamminga, D.A.; Brummelhuis, A.; Lingeman, H.

    1998-01-01

    The liquid chromatographic determination of histamine was achieved by precolumn derivatization with N-(4-aminobutyl)-N-ethylisoluminol isothiocyanate and electrochemiluminescence detection. Detection was carried out using postcolumn on-line electrochemical reagent generation and oxidation of the

  13. High sensitivity MOSFET-based neutron dosimetry

    International Nuclear Information System (INIS)

    Fragopoulou, M.; Konstantakos, V.; Zamani, M.; Siskos, S.; Laopoulos, T.; Sarrabayrouse, G.

    2010-01-01

    A new dosemeter based on a metal-oxide-semiconductor field effect transistor sensitive to both neutrons and gamma radiation was manufactured at LAAS-CNRS Laboratory, Toulouse, France. In order to be used for neutron dosimetry, a thin film of lithium fluoride was deposited on the surface of the gate of the device. The characteristics of the dosemeter, such as the dependence of its response to neutron dose and dose rate, were investigated. The studied dosemeter was very sensitive to gamma rays compared to other dosemeters proposed in the literature. Its response in thermal neutrons was found to be much higher than in fast neutrons and gamma rays.

  14. Environmental Sensitivity in Children: Development of the Highly Sensitive Child Scale and Identification of Sensitivity Groups

    Science.gov (United States)

    Pluess, Michael; Assary, Elham; Lionetti, Francesca; Lester, Kathryn J.; Krapohl, Eva; Aron, Elaine N.; Aron, Arthur

    2018-01-01

    A large number of studies document that children differ in the degree they are shaped by their developmental context with some being more sensitive to environmental influences than others. Multiple theories suggest that "Environmental Sensitivity" is a common trait predicting the response to negative as well as positive exposures.…

  15. High sensitivity optical measurement of skin gloss

    NARCIS (Netherlands)

    Ezerskaia, A.; Ras, Arno; Bloemen, Pascal; Pereira, S.F.; Urbach, Paul; Varghese, Babu

    2017-01-01

    We demonstrate a low-cost optical method for measuring the gloss properties with improved sensitivity in the low gloss regime, relevant for skin gloss properties. The gloss estimation method is based on, on the one hand, the slope of the intensity gradient in the transition regime between

  16. High sensitivity optical measurement of skin gloss

    OpenAIRE

    Ezerskaia, Anna; Ras, Arno; Bloemen, Pascal; Pereira, Silvania F.; Urbach, H. Paul; Varghese, Babu

    2017-01-01

    We demonstrate a low-cost optical method for measuring the gloss properties with improved sensitivity in the low gloss regime, relevant for skin gloss properties. The gloss estimation method is based on, on the one hand, the slope of the intensity gradient in the transition regime between specular and diffuse reflection and on the other on the sum over the intensities of pixels above threshold, derived from a camera image obtained using unpolarized white light illumination. We demonstrate the...

  17. High sensitivity optical measurement of skin gloss.

    Science.gov (United States)

    Ezerskaia, Anna; Ras, Arno; Bloemen, Pascal; Pereira, Silvania F; Urbach, H Paul; Varghese, Babu

    2017-09-01

    We demonstrate a low-cost optical method for measuring the gloss properties with improved sensitivity in the low gloss regime, relevant for skin gloss properties. The gloss estimation method is based on, on the one hand, the slope of the intensity gradient in the transition regime between specular and diffuse reflection and on the other on the sum over the intensities of pixels above threshold, derived from a camera image obtained using unpolarized white light illumination. We demonstrate the improved sensitivity of the two proposed methods using Monte Carlo simulations and experiments performed on ISO gloss calibration standards with an optical prototype. The performance and linearity of the method was compared with different professional gloss measurement devices based on the ratio of specular to diffuse intensity. We demonstrate the feasibility for in-vivo skin gloss measurements by quantifying the temporal evolution of skin gloss after application of standard paraffin cream bases on skin. The presented method opens new possibilities in the fields of cosmetology and dermatopharmacology for measuring the skin gloss and resorption kinetics and the pharmacodynamics of various external agents.

  18. The selectively bred high alcohol sensitivity (HAS) and low alcohol sensitivity (LAS) rats differ in sensitivity to nicotine.

    Science.gov (United States)

    de Fiebre, NancyEllen C; Dawson, Ralph; de Fiebre, Christopher M

    2002-06-01

    Studies in rodents selectively bred to differ in alcohol sensitivity have suggested that nicotine and ethanol sensitivities may cosegregate during selective breeding. This suggests that ethanol and nicotine sensitivities may in part be genetically correlated. Male and female high alcohol sensitivity (HAS), control alcohol sensitivity, and low alcohol sensitivity (LAS) rats were tested for nicotine-induced alterations in locomotor activity, body temperature, and seizure activity. Plasma and brain levels of nicotine and its primary metabolite, cotinine, were measured in these animals, as was the binding of [3H]cytisine, [3H]epibatidine, and [125I]alpha-bungarotoxin in eight brain regions. Both replicate HAS lines were more sensitive to nicotine-induced locomotor activity depression than the replicate LAS lines. No consistent HAS/LAS differences were seen on other measures of nicotine sensitivity; however, females were more susceptible to nicotine-induced seizures than males. No HAS/LAS differences in nicotine or cotinine levels were seen, nor were differences seen in the binding of nicotinic ligands. Females had higher levels of plasma cotinine and brain nicotine than males but had lower brain cotinine levels than males. Sensitivity to a specific action of nicotine cosegregates during selective breeding for differential sensitivity to a specific action of ethanol. The differential sensitivity of the HAS/LAS rats is due to differences in central nervous system sensitivity and not to pharmacokinetic differences. The differential central nervous system sensitivity cannot be explained by differences in the numbers of nicotinic receptors labeled in ligand-binding experiments. The apparent genetic correlation between ethanol and nicotine sensitivities suggests that common genes modulate, in part, the actions of both ethanol and nicotine and may explain the frequent coabuse of these agents.

  19. Development of electrochemiluminescent inhibition method for determination of gentian violet in aquatic water.

    Science.gov (United States)

    Wang, Sui; Hao, Tingting; Yu, Xinwei; Gai, Panpan; Guo, Zhiyong

    2012-04-01

    Gentian violet (GV) was found to quench the electrochemiluminescence (ECL) of the tris(2,2'-bipyridyl)ruthenium(II)/tris-n-propylamine (Ru(bpy)3(2+)-TPA) system at a glass carbon electrode (GCE). Based on the ECL signal changes, a simple and ultrasensitive detection method for GV in aquatic water was established. Under the optimized conditions, the quenched ECL intensity versus the logarithm of the concentration of GV was linear over a concentration range from 1.0×10(-10) to 5.0×10(-7) mol L(-1), and the limit of detection (LOD) was found to be 4.5×10(-12) mol L(-1) (S/N=3). The results obtained by the ECL system were better than other reported methods in literatures in terms of sensitivity or linear response range. The method was successfully applied to determine GV in aquatic water, and the relative standard deviations (RSDs) were found less than 6.3%, and the recoveries were obtained from 98.7 to 111.0%. Moreover, a possible mechanism of the quenching effect was primarily discussed based on UV-visible absorption spectra, cyclic voltammograms and IECL-E curves. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Target-assistant Zn2+-dependent DNAzyme for signal-on electrochemiluminescent biosensing

    International Nuclear Information System (INIS)

    Huang, Yin; Lei, Jianping; Cheng, Yan; Ju, Huangxian

    2015-01-01

    Highlights: • The sensing strategy is based on cleavage reaction of target-assistant Zn 2+ -dependent DNAzyme. • A dual quenching mechanism of ECL is identified. • A sensitive and selective ECL sensor is constructed for detection of ATP. • The biosensor can detect ATP in serum samples with good accuracy. - Abstract: A signal-on electrochemiluminescent (ECL) approach for ultrasensitive ATP detection was developed using target-assistant Zn 2+ -dependent DNAzyme via a dual quenching pathway between quantum dots (QDs) and Au nanoclusters (Au NCs). The facile ECL biosensor was constructed by covalent assembly of Au NCs-labeled hairpin DNA on QDs modified glassy carbon electrode. A dual quenching ECL mechanism was identified to be via resonance energy transfer between QDs and Au NCs and electrocatalytic reduction of coreactant oxygen by Au NCs. With the assistance of two help DNAs, the G-quadruplex structure of ATP aptamer was formed, and thus narrowed the two fragments of Zn 2+ -dependent DNAzyme. In the presence of Zn 2+ , Zn 2+ -dependent DNAzyme can be generated in situ on the biosensor's surface. The as-prepared DNAzyme can cleave the substrate strand, and release the Au NCs from the electrode, resulting in the signal-on ECL state. This biosensor showed good analytical performance with 4 orders magnitude linear range, excellent specificity, and acceptable stability. The biosensor had been applied in detection of ATP in real serum sample and provided significant potential application in clinical analysis

  1. Simultaneous determination of ethamsylate, tramadol and lidocaine in human urine by capillary electrophoresis with electrochemiluminescence detection.

    Science.gov (United States)

    Li, Jianguo; Ju, Huangxian

    2006-09-01

    Ethamsylate, tramadol and lidocaine, partly excreted by the kidney, are generally used as hemostatic, analgesic and local anesthetic in surgery. We developed a simple and sensitive method for their simultaneous monitoring in human urine based on CE coupled with electrochemiluminescence detection by end-column mode. Under optimized conditions the proposed method yielded linear ranges from 5.0 x 10(-8) to 5.0 x 10(-5), 1.0 x 10(-7) to 1.0 x 10(-4) and 1.0 x 10(-7) to 1.0 x 10(-4) M with LODs of 8.0 x 10(-9) M (36 amol), 1.6 x 10(-8) M (72 amol) and 1.0 x 10(-8) M (45 amol) (S/N = 3) for ethamsylate, tramadol and lidocaine, respectively. The RSD for their simultaneous detection at 1.0 x 10(-6) M was 2.1, 2.8 and 3.2% (n = 7), respectively. For practical application an extraction step with ethyl acetate at pH 11 was performed to eliminate the influence of the sample ionic strength. The recoveries of ethamsylate, tramadol and lidocaine at different levels in human urine were between 87 and 95%. This method was used for simultaneous detection of ethamsylate, tramadol and lidocaine in clinic urine samples from two medicated patients. It was valuable in clinical and biochemical laboratories for monitoring these drugs for various purposes.

  2. High-Sensitivity GaN Microchemical Sensors

    Science.gov (United States)

    Son, Kyung-ah; Yang, Baohua; Liao, Anna; Moon, Jeongsun; Prokopuk, Nicholas

    2009-01-01

    Systematic studies have been performed on the sensitivity of GaN HEMT (high electron mobility transistor) sensors using various gate electrode designs and operational parameters. The results here show that a higher sensitivity can be achieved with a larger W/L ratio (W = gate width, L = gate length) at a given D (D = source-drain distance), and multi-finger gate electrodes offer a higher sensitivity than a one-finger gate electrode. In terms of operating conditions, sensor sensitivity is strongly dependent on transconductance of the sensor. The highest sensitivity can be achieved at the gate voltage where the slope of the transconductance curve is the largest. This work provides critical information about how the gate electrode of a GaN HEMT, which has been identified as the most sensitive among GaN microsensors, needs to be designed, and what operation parameters should be used for high sensitivity detection.

  3. Development of a highly sensitive lithium fluoride thermoluminescence dosimeter

    International Nuclear Information System (INIS)

    Moraes da Silva, Teresinha de; Campos, Leticia Lucente

    1995-01-01

    In recent times, LiF: Mg, Cu, P thermoluminescent phosphor has been increasingly in use for radiation monitoring due its high sensitivity and ease of preparation. The Dosimetric Materials Production Laboratory of IPEN, (Nuclear Energy Institute) has developed a simple method to obtain high sensitivity LiF. The preparation method is described. (author). 4 refs., 1 fig., 1 tab

  4. Triggers for a high sensitivity charm experiment

    International Nuclear Information System (INIS)

    Christian, D.C.

    1994-07-01

    Any future charm experiment clearly should implement an E T trigger and a μ trigger. In order to reach the 10 8 reconstructed charm level for hadronic final states, a high quality vertex trigger will almost certainly also be necessary. The best hope for the development of an offline quality vertex trigger lies in further development of the ideas of data-driven processing pioneered by the Nevis/U. Mass. group

  5. Electrochemistry and electrochemiluminescence from a redox-active metal-organic framework.

    Science.gov (United States)

    Xu, Yang; Yin, Xue-Bo; He, Xi-Wen; Zhang, Yu-Kui

    2015-06-15

    The marriage of metal-organic frameworks (MOFs) and electrochemiluminescence (ECL) can combine their merits together. Designing ECL-active MOF with a high electron transfer capacity and high stability is critical for ECL emission. Here we reported the ECL from a redox-active MOF prepared from {Ru[4,4'-(HO2C)2-bpy]2bpy}(2+) and Zn(2+); a property of MOFs has not been reported previously. The MOF structure is independent of its charge and is therefore stable electrochemically. The redox-activity and well-ordered porous structure of the MOF were confirmed by its electrochemical properties and ECL emission. The high ECL emission indicated the ease of electron transfer between the MOF and co-reactants. Furthermore, the MOF exhibited permselectivity, charge selectivity, and catalytic selectivity along with a stable and concentration-dependent ECL emission toward co-reactants. ECL mechanism was proposed based on the results. The detection and recovery of cocaine in the serum sample was used to validate the feasibility of MOF- based ECL system. The information obtained in this study provides a better understanding of the redox properties of MOFs and their potential electrochemical applications. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Low Power and High Sensitivity MOSFET-Based Pressure Sensor

    International Nuclear Information System (INIS)

    Zhang Zhao-Hua; Ren Tian-Ling; Zhang Yan-Hong; Han Rui-Rui; Liu Li-Tian

    2012-01-01

    Based on the metal-oxide-semiconductor field effect transistor (MOSFET) stress sensitive phenomenon, a low power MOSFET pressure sensor is proposed. Compared with the traditional piezoresistive pressure sensor, the present pressure sensor displays high performances on sensitivity and power consumption. The sensitivity of the MOSFET sensor is raised by 87%, meanwhile the power consumption is decreased by 20%. (cross-disciplinary physics and related areas of science and technology)

  7. Ternary Electrochemiluminescence System Based on Rubrene Microrods as Luminophore and Pt Nanomaterials as Coreaction Accelerator for Ultrasensitive Detection of MicroRNA from Cancer Cells.

    Science.gov (United States)

    Liu, Jia-Li; Tang, Zhi-Ling; Zhuo, Ying; Chai, Ya-Qin; Yuan, Ruo

    2017-09-05

    As the only endogenous coreactant in the electrochemiluminescence (ECL) system, the dissolved O 2 was the ideal candidate due to the mild reaction and easy operation, but compared to S 2 O 8 2- , the dissolved O 2 with weaker redox activity suffers from the poor enhancement effect of the luminophore, which restricted the further application in bioanalysis. Here, a high-intense ECL signal was gained by the employing of Pt nanomaterials as a coreaction accelerator to generate more of the intermediate of dissolved O 2 to promote the coreaction efficiency. On the basis of a new ternary ECL system of Pt nanomaterials as the coreaction accelerator, dissolved O 2 as the coreactant, and a neotype rubrene microrods as the luminophore, an efficient "on-off-on" solid-state ECL switch platfrom was designed for ultrasensitive microRNA (miRNA) detection with a background reduction strategy of ferrocene-labeled single-stranded DNA (Fc-DNA) as a quencher. In the presence of miRNA 141, the Pt nanoparticles labeled hairpin (HP1/PtNPs) was opened to produce plenty of Pt nanoparticles labeled output DNA (S1/PtNPs) and release the miRNA-141 to participate in the next cycle. Then, the S1/PtNPs were captured on the surface of the electrode by the complementary strand to obtain the super "signal on" state with extremely high ECL signal. This novel solid-state ECL platform exhibited excellent sensitivity from 10 aM to 100 pM with a detection limit of 2.1 aM, which provided a new approach for ultrasensitive ECL bioanalysis.

  8. Novel charge sensitive preamplifier without high-value feedback resistor

    International Nuclear Information System (INIS)

    Xi Deming

    1992-01-01

    A novel charge sensitive preamplifier is introduced. The method of removing the high value feedback resistor, the circuit design and analysis are described. A practical circuit and its measured performances are provided

  9. An "off-on" electrochemiluminescent biosensor based on DNAzyme-assisted target recycling and rolling circle amplifications for ultrasensitive detection of microRNA.

    Science.gov (United States)

    Zhang, Pu; Wu, Xiaoyan; Yuan, Ruo; Chai, Yaqin

    2015-03-17

    In this study, an off-on switching of a dual amplified electrochemiluminescence (ECL) biosensor based on Pb(2+)-induced DNAzyme-assisted target recycling and rolling circle amplification (RCA) was constructed for microRNA (miRNA) detection. First, the primer probe with assistant probe and miRNA formed Y junction which was cleaved with the addition of Pb(2+) to release miRNA. Subsequently, the released miRNA could initiate the next recycling process, leading to the generation of numerous intermediate DNA sequences (S2). Afterward, bare glassy carbon electrode (GCE) was immersed into HAuCl4 solution to electrodeposit a Au nanoparticle layer (depAu), followed by the assembly of a hairpin probe (HP). Then, dopamine (DA)-modified DNA sequence (S1) was employed to hybridize with HP, which switching off the sensing system. This is the first work that employs DA to quench luminol ECL signal, possessing the biosensor ultralow background signal. Afterward, S2 produced by the target recycling process was loaded onto the prepared electrode to displace S1 and served as an initiator for RCA. With rational design, numerous repeated DNA sequences coupling with hemin to form hemin/G-quadruplex were generated, which could exhibit strongly catalytic toward H2O2, thus amplified the ECL signal and switched the ON state of the sensing system. The liner range for miRNA detection was from 1.0 fM to 100 pM with a low detection limit down to 0.3 fM. Moreover, with the high sensitivity and specificity induced by the dual signal amplification, the proposed miRNA biosensor holds great potential for analysis of other interesting tumor markers.

  10. Electrochemiluminescence quenching of luminol by CuS in situ grown on reduced graphene oxide for detection of N-terminal pro-brain natriuretic peptide.

    Science.gov (United States)

    Li, Xiaojian; Lu, Peng; Wu, Bin; Wang, Yaoguang; Wang, Huan; Du, Bin; Pang, Xuehui; Wei, Qin

    2018-07-30

    A novel electrochemiluminescence (ECL) signal-off strategy based on CuS in situ grown on reduced graphene oxide (CuS-rGO) quenching luminol/H 2 O 2 system was firstly proposed. Luminol was grafted on the surface of Au@Fe 3 O 4 -Cu 3 (PO 4 ) 2 nanoflowers (Luminol-Au@Fe 3 O 4 -Cu 3 (PO 4 ) 2 ) which exhibited excellent catalytic effect towards the reduction of H 2 O 2 to enhance the ECL intensity of luminol. Cu 3 (PO 4 ) 2 nanoflowers showed large surface area which can immobilize more Fe 3 O 4 and Au nanoparticles. The quenching mechanism of CuS-rGO was due to ECL resonance energy transfer (RET). The spectral overlap between fluorescence spectrum of Luminol-Au@Fe 3 O 4 -Cu 3 (PO 4 ) 2 and UV-vis absorption spectrum of CuS-rGO revealed that resonance energy transfer was possible. Au nanoparticles were immobilized on the surface of CuS-rGO to capture secondary antibodies. After a sandwich-type immunoreaction, a remarkable decrease of ECL signal was observed. Under the optimal conditions, the immunosensor showed excellent performance for N-terminal pro-brain natriuretic peptide (NT-proBNP) detection with a wide detection range from 0.5 pg mL -1 to 20 ng mL -1 and a low detection limit of 0.12 pg mL -1 (S/N = 3). The prepared NT-proBNP immunosensor displayed high sensitivity, excellent stability and good specificity. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. A high-sensitivity neutron counter and waste-drum counting with the high-sensitivity neutron instrument

    International Nuclear Information System (INIS)

    Hankins, D.E.; Thorngate, J.H.

    1993-04-01

    At Lawrence Livermore National Laboratory (LLNL), a highly sensitive neutron counter was developed that can detect and accurately measure the neutrons from small quantities of plutonium or from other low-level neutron sources. This neutron counter was originally designed to survey waste containers leaving the Plutonium Facility. However, it has proven to be useful in other research applications requiring a high-sensitivity neutron instrument

  12. Simultaneous determination of psychotropic drugs in human urine by capillary electrophoresis with electrochemiluminescence detection

    Energy Technology Data Exchange (ETDEWEB)

    Li Jianguo [Key Laboratory of Analytical Chemistry for Life Science (Education Ministry of China), School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China); School of Chemistry and Chemical Engineering, Suzhou University, Suzhou 215006 (China); Zhao Fengjuan [Key Laboratory of Analytical Chemistry for Life Science (Education Ministry of China), School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China); Ju Huangxian [Key Laboratory of Analytical Chemistry for Life Science (Education Ministry of China), School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China)]. E-mail: hxju@nju.edu.cn

    2006-08-04

    Amitriptyline, doxepin and chlorpromazine are often used as psychotropic drugs in treatment of the various mental diseases, and are also partly excreted by kidney. This work developed a simple, selective and sensitive method for their simultaneous monitoring in human urine using capillary electrophoresis coupled with electrochemiluminescence (ECL) detection based on end-column ECL reaction of tris-(2,2'-bipyridyl)ruthenium(II) with aliphatic tertiary amino moieties. Acetone was used as an additive to the running buffer to obtain their absolute separation. Under optimized conditions the proposed method displayed a linear range from 5.0 to 800 ng mL{sup -1} for the three drugs with the correlation coefficients more than 0.995 (n = 8). Their limits of detection were 0.8 ng mL{sup -1} (3.6 fg), 1.0 ng mL{sup -1} (4.5 fg) and 1.5 ng mL{sup -1} (6.8 fg) at a signal to noise ratio of 3, respectively. The relative standard deviations for five determinations of 20 ng mL{sup -1} amitriptyline, doxepin and chlorpromazine were 1.7%, 4.2% and 3.6%, respectively. For practical application an extract step with 90:10 heptane/ethyl acetate (v/v) was performed to eliminate the influence of ionic strength in sample. The recoveries of amitriptyline, doxepin and chlorpromazine at different levels in human urine were between 83% and 93%, which showed that the method was valuable in clinical and biochemical laboratories for monitoring amitriptyline, doxepin and chlorpromazine.

  13. Achieving sensitive, high-resolution laser spectroscopy at CRIS

    Energy Technology Data Exchange (ETDEWEB)

    Groote, R. P. de [Instituut voor Kern- en Stralingsfysica, KU Leuven (Belgium); Lynch, K. M., E-mail: kara.marie.lynch@cern.ch [EP Department, CERN, ISOLDE (Switzerland); Wilkins, S. G. [The University of Manchester, School of Physics and Astronomy (United Kingdom); Collaboration: the CRIS collaboration

    2017-11-15

    The Collinear Resonance Ionization Spectroscopy (CRIS) experiment, located at the ISOLDE facility, has recently performed high-resolution laser spectroscopy, with linewidths down to 20 MHz. In this article, we present the modifications to the beam line and the newly-installed laser systems that have made sensitive, high-resolution measurements possible. Highlights of recent experimental campaigns are presented.

  14. Signal-off Electrochemiluminescence Biosensor Based on Phi29 DNA Polymerase Mediated Strand Displacement Amplification for MicroRNA Detection.

    Science.gov (United States)

    Chen, Anyi; Gui, Guo-Feng; Zhuo, Ying; Chai, Ya-Qin; Xiang, Yun; Yuan, Ruo

    2015-06-16

    A target induced cycling strand displacement amplification (SDA) mediated by phi29 DNA polymerase (phi29) was first investigated and applied in a signal-off electrochemiluminescence (ECL) biosensor for microRNA (miRNA) detection. Herein, the target miRNA triggered the phi29-mediated SDA which could produce amounts of single-stranded DNA (assistant probe) with accurate and comprehensive nucleotide sequence. Then, the assistant probe hybridized with the capture probe and the ferrocene-labeled probe (Fc-probe) to form a ternary "Y" structure for ECL signal quenching by ferrocene. Therefore, the ECL intensity would decrease with increasing concentration of the target miRNA, and the sensitivity of biosensor would be promoted on account of the efficient signal amplification of the target induced cycling reaction. Besides, a self-enhanced Ru(II) ECL system was designed to obtain a stable and strong initial signal to further improve the sensitivity. The ECL assay for miRNA-21 detection is developed with excellent sensitivity of a concentration variation from 10 aM to 1.0 pM and limit of detection down to 3.3 aM.

  15. Retinal sensitivity and choroidal thickness in high myopia.

    Science.gov (United States)

    Zaben, Ahmad; Zapata, Miguel Á; Garcia-Arumi, Jose

    2015-03-01

    To estimate the association between choroidal thickness in the macular area and retinal sensitivity in eyes with high myopia. This investigation was a transversal study of patients with high myopia, all of whom had their retinal sensitivity measured with macular integrity assessment microperimetry. The choroidal thicknesses in the macular area were then measured by optical coherence tomography, and statistical correlations between their functionality and the anatomical structuralism, as assessed by both types of measurements, were analyzed. Ninety-six eyes from 77 patients with high myopia were studied. The patients had a mean age ± standard deviation of 38.9 ± 13.2 years, with spherical equivalent values ranging from -6.00 diopter to -20.00 diopter (8.74 ± 2.73 diopter). The mean central choroidal thickness was 159.00 ± 50.57. The mean choroidal thickness was directly correlated with sensitivity (r = 0.306; P = 0.004) and visual acuity but indirectly correlated with the spherical equivalent values and patient age. The mean sensitivity was not significantly correlated with the macular foveal thickness (r = -0.174; P = 0.101) or with the overall macular thickness (r = 0.103; P = 0.334); furthermore, the mean sensitivity was significantly correlated with visual acuity (r = 0.431; P < 0.001) and the spherical equivalent values (r = -0.306; P = 0.003). Retinal sensitivity in highly myopic eyes is directly correlated with choroidal thickness and does not seem to be associated with retinal thickness. Thus, in patients with high myopia, accurate measurements of choroidal thickness may provide more accurate information about this pathologic condition because choroidal thickness correlates to a greater degree with the functional parameters, patient age, and spherical equivalent values.

  16. Electrochemiluminescence assays for insulin and glutamic acid decarboxylase autoantibodies improve prediction of type 1 diabetes risk.

    Science.gov (United States)

    Miao, Dongmei; Steck, Andrea K; Zhang, Li; Guyer, K Michelle; Jiang, Ling; Armstrong, Taylor; Muller, Sarah M; Krischer, Jeffrey; Rewers, Marian; Yu, Liping

    2015-02-01

    We recently developed new electrochemiluminescence (ECL) insulin autoantibody (IAA) and glutamic acid decarboxylase 65 autoantibody (GADA) assays that discriminate high-affinity, high-risk diabetes-specific autoantibodies from low-affinity, low-risk islet autoantibodies (iAbs) detected by radioassay (RAD). Here, we report a further validation of the ECL-IAA and -GADA assays in 3,484 TrialNet study participants. The ECL assay and RAD were congruent in those with prediabetes and in subjects with multiple autoantibodies, but only 24% (P<0.0001) of single RAD-IAA-positive and 46% (P<0.0001) of single RAD-GADA-positive were confirmed by the ECL-IAA and -GADA assays, respectively. During a follow-up (mean, 2.4 years), 51% of RAD-IAA-positive and 63% of RAD-GADA-positive subjects not confirmed by ECL became iAb negative, compared with only 17% of RAD-IAA-positive (P<0.0001) and 15% of RAD-GADA-positive (P<0.0001) subjects confirmed by ECL assays. Among subjects with multiple iAbs, diabetes-free survival was significantly shorter if IAA or GADA was positive by ECL and negative by RAD than if IAA or GADA was negative by ECL and positive by RAD (P<0.019 and P<0.0001, respectively). Both positive and negative predictive values in terms of progression to type 1 diabetes mellitus were superior for ECL-IAA and ECL-GADA, compared with RADs. The prevalence of the high-risk human leukocyte antigen-DR3/4, DQB1*0302 genotype was significantly higher in subjects with RAD-IAA or RAD-GADA confirmed by ECL. In conclusion, both ECL-IAA and -GADA are more disease-specific and better able to predict the risk of progression to type 1 diabetes mellitus than the current standard RADs.

  17. Integration of intracellular telomerase monitoring by electrochemiluminescence technology and targeted cancer therapy by reactive oxygen species.

    Science.gov (United States)

    Zhang, Huairong; Li, Binxiao; Sun, Zhaomei; Zhou, Hong; Zhang, Shusheng

    2017-12-01

    Cancer therapies based on reactive oxygen species (ROS) have emerged as promising clinical treatments. Electrochemiluminescence (ECL) technology has also attracted considerable attention in the field of clinical diagnosis. However, studies about the integration of ECL diagnosis and ROS cancer therapy are very rare. Here we introduce a novel strategy that employs ECL technology and ROS to fill the above vacancy. Briefly, an ITO electrode was electrodeposited with polyluminol-Pt NPs composite films and modified with aptamer DNA to capture HL-60 cancer cells with high specificity. After that, mesoporous silica nanoparticles (MSNs) filled with phorbol 12-myristate 13-acetate (PMA) were closed by the telomerase primer DNA (T-primer DNA) and aptamer. After aptamer on MSN@PMA recognized and combined with the HL-60 cancer cells with high specificity, T-primer DNA on MSN@PMA could be moved away from the MSN@PMA surface after extension by telomerase in the HL-60 cancer cells and PMA was released to induce the production of ROS by the HL-60 cancer cells. After that, the polyluminol-Pt NPs composite films could react with hydrogen peroxide (a major ROS) and generate an ECL signal. Thus the intracellular telomerase activity of the HL-60 cancer cells could be detected in situ . Besides, ROS could induce apoptosis in the HL-60 cancer cells with high efficacy by causing oxidative damage to the lipids, protein, and DNA. Above all, the designed platform could not only detect intracellular telomerase activity instead of that of extracted telomerase, but could also kill targeted tumors by ECL technology and ROS.

  18. BH3105 type neutron dose equivalent meter of high sensitivity

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Enshan; Yang Jianfeng; Zhang Hong; Huang Jiling

    1995-10-01

    It is noted that to design a neutron dose meter of high sensitivity is almost impossible in the frame of traditional designing principle--'absorption net principle'. Based on a newly proposed principle of obtaining neutron dose equi-biological effect adjustment--' absorption stick principle', a brand-new neutron dose-equivalent meter with high neutron sensitivity BH3105 has been developed. Its sensitivity reaches 10 cps/(μSv·h -1 ), which is 18∼40 times higher than one of foreign products of the same kind and is 10 4 times higher than that of domestic FJ342 neutron rem-meter. BH3105 has a measurement range from 0.1μSv/h to 1 Sv/h which is 1 or 2 orders wider than that of the other's. It has the advanced properties of gamma-resistance, energy response, orientation, etc. (6 tabs., 5 figs.)

  19. A high sensitivity nanomaterial based SAW humidity sensor

    Energy Technology Data Exchange (ETDEWEB)

    Wu, T-T; Chou, T-H [Institute of Applied Mechanics, National Taiwan University, Taipei 106, Taiwan (China); Chen, Y-Y [Department of Mechanical Engineering, Tatung University, Taipei 104, Taiwan (China)], E-mail: wutt@ndt.iam.ntu.edu.tw

    2008-04-21

    In this paper, a highly sensitive humidity sensor is reported. The humidity sensor is configured by a 128{sup 0}YX-LiNbO{sub 3} based surface acoustic wave (SAW) resonator whose operating frequency is at 145 MHz. A dual delay line configuration is realized to eliminate external temperature fluctuations. Moreover, for nanostructured materials possessing high surface-to-volume ratio, large penetration depth and fast charge diffusion rate, camphor sulfonic acid doped polyaniline (PANI) nanofibres are synthesized by the interfacial polymerization method and further deposited on the SAW resonator as selective coating to enhance sensitivity. The humidity sensor is used to measure various relative humidities in the range 5-90% at room temperature. Results show that the PANI nanofibre based SAW humidity sensor exhibits excellent sensitivity and short-term repeatability.

  20. Performance of terahertz metamaterials as high-sensitivity sensor

    Science.gov (United States)

    He, Yanan; Zhang, Bo; Shen, Jingling

    2017-09-01

    A high-sensitivity sensor based on the resonant transmission characteristics of terahertz (THz) metamaterials was investigated, with the proposal and fabrication of rectangular bar arrays of THz metamaterials exhibiting a period of 180 μm on a 25 μm thick flexible polyimide. Varying the size of the metamaterial structure revealed that the length of the rectangular unit modulated the resonant frequency, which was verified by both experiment and simulation. The sensing characteristics upon varying the surrounding media in the sample were tested by simulation and experiment. Changing the surrounding medium from that of air to that of alcohol or oil produced resonant frequency redshifts of 80 GHz or 150 GHz, respectively, which indicates that the sensor possessed a high sensitivity of 667 GHz per unit of refractive index. Finally, the influence of the sample substrate thickness on the sensor sensitivity was investigated by simulation. It may be a reference for future sensor design.

  1. Sensitive high performance liquid chromatographic method for the ...

    African Journals Online (AJOL)

    A new simple, sensitive, cost-effective and reproducible high performance liquid chromatographic (HPLC) method for the determination of proguanil (PG) and its metabolites, cycloguanil (CG) and 4-chlorophenylbiguanide (4-CPB) in urine and plasma is described. The extraction procedure is a simple three-step process ...

  2. Methylation-Sensitive High Resolution Melting (MS-HRM).

    Science.gov (United States)

    Hussmann, Dianna; Hansen, Lise Lotte

    2018-01-01

    Methylation-Sensitive High Resolution Melting (MS-HRM) is an in-tube, PCR-based method to detect methylation levels at specific loci of interest. A unique primer design facilitates a high sensitivity of the assays enabling detection of down to 0.1-1% methylated alleles in an unmethylated background.Primers for MS-HRM assays are designed to be complementary to the methylated allele, and a specific annealing temperature enables these primers to anneal both to the methylated and the unmethylated alleles thereby increasing the sensitivity of the assays. Bisulfite treatment of the DNA prior to performing MS-HRM ensures a different base composition between methylated and unmethylated DNA, which is used to separate the resulting amplicons by high resolution melting.The high sensitivity of MS-HRM has proven useful for detecting cancer biomarkers in a noninvasive manner in urine from bladder cancer patients, in stool from colorectal cancer patients, and in buccal mucosa from breast cancer patients. MS-HRM is a fast method to diagnose imprinted diseases and to clinically validate results from whole-epigenome studies. The ability to detect few copies of methylated DNA makes MS-HRM a key player in the quest for establishing links between environmental exposure, epigenetic changes, and disease.

  3. Aluminum nano-cantilevers for high sensitivity mass sensors

    DEFF Research Database (Denmark)

    Davis, Zachary James; Boisen, Anja

    2005-01-01

    We have fabricated Al nano-cantilevers using a very simple one mask contact UV lithography technique with lateral dimensions under 500 nm and vertical dimensions of approximately 100 nm. These devices are demonstrated as highly sensitive mass sensors by measuring their dynamic properties. Further...

  4. High sensitivity probe absorption technique for time-of-flight ...

    Indian Academy of Sciences (India)

    Abstract. We report on a phase-sensitive probe absorption technique with high sen- sitivity, capable of detecting a few hundred ultra-cold atoms in flight in an observation time of a few milliseconds. The large signal-to-noise ratio achieved is sufficient for reliable measurements on low intensity beams of cold atoms.

  5. Highly sensitive detection using microring resonator and nanopores

    Science.gov (United States)

    Bougot-Robin, K.; Hoste, J. W.; Le Thomas, N.; Bienstman, P.; Edel, J. B.

    2016-04-01

    One of the most significant challenges facing physical and biological scientists is the accurate detection and identification of single molecules in free-solution environments. The ability to perform such sensitive and selective measurements opens new avenues for a large number of applications in biological, medical and chemical analysis, where small sample volumes and low analyte concentrations are the norm. Access to information at the single or few molecules scale is rendered possible by a fine combination of recent advances in technologies. We propose a novel detection method that combines highly sensitive label-free resonant sensing obtained with high-Q microcavities and position control in nanoscale pores (nanopores). In addition to be label-free and highly sensitive, our technique is immobilization free and does not rely on surface biochemistry to bind probes on a chip. This is a significant advantage, both in term of biology uncertainties and fewer biological preparation steps. Through combination of high-Q photonic structures with translocation through nanopore at the end of a pipette, or through a solid-state membrane, we believe significant advances can be achieved in the field of biosensing. Silicon microrings are highly advantageous in term of sensitivity, multiplexing, and microfabrication and are chosen for this study. In term of nanopores, we both consider nanopore at the end of a nanopipette, with the pore being approach from the pipette with nanoprecise mechanical control. Alternatively, solid state nanopores can be fabricated through a membrane, supporting the ring. Both configuration are discussed in this paper, in term of implementation and sensitivity.

  6. NK sensitivity of neuroblastoma cells determined by a highly sensitive coupled luminescent method

    International Nuclear Information System (INIS)

    Ogbomo, Henry; Hahn, Anke; Geiler, Janina; Michaelis, Martin; Doerr, Hans Wilhelm; Cinatl, Jindrich

    2006-01-01

    The measurement of natural killer (NK) cells toxicity against tumor or virus-infected cells especially in cases with small blood samples requires highly sensitive methods. Here, a coupled luminescent method (CLM) based on glyceraldehyde-3-phosphate dehydrogenase release from injured target cells was used to evaluate the cytotoxicity of interleukin-2 activated NK cells against neuroblastoma cell lines. In contrast to most other methods, CLM does not require the pretreatment of target cells with labeling substances which could be toxic or radioactive. The effective killing of tumor cells was achieved by low effector/target ratios ranging from 0.5:1 to 4:1. CLM provides highly sensitive, safe, and fast procedure for measurement of NK cell activity with small blood samples such as those obtained from pediatric patients

  7. Instruction manual for ORNL tandem high abundance sensitivity mass spectrometer

    International Nuclear Information System (INIS)

    Smith, D.H.; McKown, H.S.; Chrisite, W.H.; Walker, R.L.; Carter, J.A.

    1976-06-01

    This manual describes the physical characteristics of the tandem mass spectrometer built by Oak Ridge National Laboratory for the International Atomic Energy Agency. Specific requirements met include ability to run small samples, high abundance sensitivity, good precision and accuracy, and adequate sample throughput. The instrument is capable of running uranium samples as small as 10 -12 g and has an abundance sensitivity in excess of 10 6 . Precision and accuracy are enhanced by a special sweep control circuit. Sample throughput is 6 to 12 samples per day. Operating instructions are also given

  8. A highly sensitive and specific assay for vertebrate collagenase

    International Nuclear Information System (INIS)

    Sodek, J.; Hurum, S.; Feng, J.

    1981-01-01

    A highly sensitive and specific assay for vertebrate collagenase has been developed using a [ 14 C]-labeled collagen substrate and a combination of SDS-PAGE (sodium dodecyl sulfate-polyacrylamide gel electrophoresis) and fluorography to identify and quantitate the digestion products. The assay was sufficiently sensitive to permit the detection and quantitation of collagenase activity in 0.1 μl of gingival sulcal fluid, and in samples of cell culture medium without prior concentration. The assay has also been used to detect the presence of inhibitors of collagenolytic enzymes in various cell culture fluids. (author)

  9. Multiplex electrochemiluminescence DNA sensor for determination of hepatitis B virus and hepatitis C virus based on multicolor quantum dots and Au nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Linlin; Wang, Xinyan; Ma, Qiang; Lin, Zihan; Chen, Shufan; Li, Yang [Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012 (China); Lu, Lehui [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022 (China); Qu, Hongping [Department of Biotechnology, College of Life Science, Jilin Normal University, Siping, 136000 (China); Su, Xingguang, E-mail: suxg@jlu.edu.cn [Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012 (China)

    2016-04-15

    In this work, a novel multiplex electrochemiluminescence (ECL) DNA sensor has been developed for determination of hepatitis B virus (HBV) and hepatitis C virus (HCV) based on multicolor CdTe quantum dots (CdTe QDs) and Au nanoparticles (Au NPs). The electrochemically synthesized graphene nanosheets (GNs) were selected as conducting bridge to anchor CdTe QDs{sub 551}-capture DNA{sub HBV} and CdTe QDs{sub 607}-capture DNA{sub HCV} on the glassy carbon electrode (GCE). Then, different concentrations of target DNA{sub HBV} and target DNA{sub HCV} were introduced to hybrid with complementary CdTe QDs-capture DNA. Au NPs-probe DNA{sub HBV} and Au NPs-probe DNA{sub HCV} were modified to the above composite film via hybrid with the unreacted complementary CdTe QDs-capture DNA. Au NPs could quench the electrochemiluminescence (ECL) intensity of CdTe QDs due to the inner filter effect. Therefore, the determination of target DNA{sub HBV} and target DNA{sub HCV} could be achieved by monitoring the ECL DNA sensor based on Au NPs-probe DNA/target DNA/CdTe QDs-capture DNA/GNs/GCE composite film. Under the optimum conditions, the ECL intensity of CdTe QDs{sub 551} and CdTe QDs{sub 607} and the concentration of target DNA{sub HBV} and target DNA{sub HCV} have good linear relationship in the range of 0.0005–0.5 nmol L{sup −1} and 0.001–1.0 nmol L{sup −1} respectively, and the limit of detection were 0.082 pmol L{sup −1} and 0.34 pmol L{sup −1} respectively (S/N = 3). The DNA sensor showed good sensitivity, selectivity, reproducibility and acceptable stability. The proposed DNA sensor has been employed for the determination of target DNA{sub HBV} and target DNA{sub HCV} in human serum samples with satisfactory results. - Highlights: • A novel electrochemiluminescence DNA sensor has been developed for the determination of target DNA{sub HBV} and target DNA{sub HCV}. • The DNA sensor shows good sensitivity, reproducibility and stability. • The ECL provided a

  10. The sandwich-type electrochemiluminescence immunosensor for α-fetoprotein based on enrichment by Fe3O4-Au magnetic nano probes and signal amplification by CdS-Au composite nanoparticles labeled anti-AFP.

    Science.gov (United States)

    Zhou, Hankun; Gan, Ning; Li, Tianhua; Cao, Yuting; Zeng, Saolin; Zheng, Lei; Guo, Zhiyong

    2012-10-09

    A novel and sensitive sandwich-type electrochemiluminescence (ECL) immunosensor was fabricated on a glassy carbon electrode (GCE) for ultra trace levels of α-fetoprotein (AFP) based on sandwich immunoreaction strategy by enrichment using magnetic capture probes and quantum dots coated with Au shell (CdS-Au) as the signal tag. The capture probe was prepared by immobilizing the primary antibody of AFP (Ab1) on the core/shell Fe(3)O(4)-Au nanoparticles, which was first employed to capture AFP antigens to form Fe(3)O(4)-Au/Ab1/AFP complex from the serum after incubation. The product can be separated from the background solution through the magnetic separation. Then the CdS-Au labeled secondary antibody (Ab2) as signal tag (CdS-Au/Ab2) was conjugated successfully with Fe(3)O(4)-Au/Ab1/AFP complex to form a sandwich-type immunocomplex (Fe(3)O(4)-Au/Ab1/AFP/Ab2/CdS-Au), which can be further separated by an external magnetic field and produce ECL signals at a fixed voltage. The signal was proportional to a certain concentration range of AFP for quantification. Thus, an easy-to-use immunosensor with magnetic probes and a quantum dots signal tag was obtained. The immunosensor performed at a level of high sensitivity and a broad concentration range for AFP between 0.0005 and 5.0 ng mL(-1) with a detection limit of 0.2 pg mL(-1). The use of magnetic probes was combined with pre-concentration and separation for trace levels of tumor markers in the serum. Due to the amplification of the signal tag, the immunosensor is highly sensitive, which can offer great promise for rapid, simple, selective and cost-effective detection of effective biomonitoring for clinical application. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Are inflationary predictions sensitive to very high energy physics?

    International Nuclear Information System (INIS)

    Burgess, C.P.; Lemieux, F.; Holman, R.; Cline, J.M.

    2003-01-01

    It has been proposed that the successful inflationary description of density perturbations on cosmological scales is sensitive to the details of physics at extremely high (trans-Planckian) energies. We test this proposal by examining how inflationary predictions depend on higher-energy scales within a simple model where the higher-energy physics is well understood. We find the best of all possible worlds: inflationary predictions are robust against the vast majority of high-energy effects, but can be sensitive to some effects in certain circumstances, in a way which does not violate ordinary notions of decoupling. This implies both that the comparison of inflationary predictions with CMB data is meaningful, and that it is also worth searching for small deviations from the standard results in the hopes of learning about very high energies. (author)

  12. Design of highly sensitive multichannel bimetallic photonic crystal fiber biosensor

    Science.gov (United States)

    Hameed, Mohamed Farhat O.; Alrayk, Yassmin K. A.; Shaalan, Abdelhamid A.; El Deeb, Walid S.; Obayya, Salah S. A.

    2016-10-01

    A design of a highly sensitive multichannel biosensor based on photonic crystal fiber is proposed and analyzed. The suggested design has a silver layer as a plasmonic material coated by a gold layer to protect silver oxidation. The reported sensor is based on detection using the quasi transverse electric (TE) and quasi transverse magnetic (TM) modes, which offers the possibility of multichannel/multianalyte sensing. The numerical results are obtained using a finite element method with perfect matched layer boundary conditions. The sensor geometrical parameters are optimized to achieve high sensitivity for the two polarized modes. High-refractive index sensitivity of about 4750 nm/RIU (refractive index unit) and 4300 nm/RIU with corresponding resolutions of 2.1×10-5 RIU, and 2.33×10-5 RIU can be obtained according to the quasi TM and quasi TE modes of the proposed sensor, respectively. Further, the reported design can be used as a self-calibration biosensor within an unknown analyte refractive index ranging from 1.33 to 1.35 with high linearity and high accuracy. Moreover, the suggested biosensor has advantages in terms of compactness and better integration of microfluidics setup, waveguide, and metallic layers into a single structure.

  13. Development of High Sensitivity Nuclear Emulsion and Fine Grained Emulsion

    Science.gov (United States)

    Kawahara, H.; Asada, T.; Naka, T.; Naganawa, N.; Kuwabara, K.; Nakamura, M.

    2014-08-01

    Nuclear emulsion is a particle detector having high spacial resolution and angular resolution. It became useful for large statistics experiment thanks to the development of automatic scanning system. In 2010, a facility for emulsion production was introduced and R&D of nuclear emulsion began at Nagoya university. In this paper, we present results of development of the high sensitivity emulsion and fine grained emulsion for dark matter search experiment. Improvement of sensitivity is achieved by raising density of silver halide crystals and doping well-adjusted amount of chemicals. Production of fine grained emulsion was difficult because of unexpected crystal condensation. By mixing polyvinyl alcohol (PVA) to gelatin as a binder, we succeeded in making a stable fine grained emulsion.

  14. Development of High Sensitivity Nuclear Emulsion and Fine Grained Emulsion

    International Nuclear Information System (INIS)

    Kawahara, H.; Asada, T.; Naka, T.; Naganawa, N.; Kuwabara, K.; Nakamura, M.

    2014-01-01

    Nuclear emulsion is a particle detector having high spacial resolution and angular resolution. It became useful for large statistics experiment thanks to the development of automatic scanning system. In 2010, a facility for emulsion production was introduced and R and D of nuclear emulsion began at Nagoya university. In this paper, we present results of development of the high sensitivity emulsion and fine grained emulsion for dark matter search experiment. Improvement of sensitivity is achieved by raising density of silver halide crystals and doping well-adjusted amount of chemicals. Production of fine grained emulsion was difficult because of unexpected crystal condensation. By mixing polyvinyl alcohol (PVA) to gelatin as a binder, we succeeded in making a stable fine grained emulsion

  15. Online high sensitivity measurement system for transuranic aerosols

    International Nuclear Information System (INIS)

    Kordas, J.F.; Phelps, P.L.

    1976-01-01

    A measurement system for transuranic aerosols has been designed that will be able to withstand the corrosive nature of stack effluents and yet have extremely high sensitivity. It will be capable of measuring 1 maximum permissible concentration (MPC) of plutonium or americium in 30 minutes with a fractional standard deviation of less than 0.33. Background resulting from 218 Po is eliminated by alpha energy discrimination and a decay scheme analysis. A microprocessor controls all data acquisition, data reduction, and instrument calibration

  16. Recent trends in high spin sensitivity magnetic resonance

    Science.gov (United States)

    Blank, Aharon; Twig, Ygal; Ishay, Yakir

    2017-07-01

    new ideas, show how these limiting factors can be mitigated to significantly improve the sensitivity of induction detection. Finally, we outline some directions for the possible applications of high-sensitivity induction detection in the field of electron spin resonance.

  17. High-sensitivity bend angle measurements using optical fiber gratings.

    Science.gov (United States)

    Rauf, Abdul; Zhao, Jianlin; Jiang, Biqiang

    2013-07-20

    We present a high-sensitivity and more flexible bend measurement method, which is based on the coupling of core mode to the cladding modes at the bending region in concatenation with optical fiber grating serving as band reflector. The characteristics of a bend sensing arm composed of bending region and optical fiber grating is examined for different configurations including single fiber Bragg grating (FBG), chirped FBG (CFBG), and double FBGs. The bend loss curves for coated, stripped, and etched sections of fiber in the bending region with FBG, CFBG, and double FBG are obtained experimentally. The effect of separation between bending region and optical fiber grating on loss is measured. The loss responses for single FBG and CFBG configurations are compared to discover the effectiveness for practical applications. It is demonstrated that the sensitivity of the double FBG scheme is twice that of the single FBG and CFBG configurations, and hence acts as sensitivity multiplier. The bend loss response for different fiber diameters obtained through etching in 40% hydrofluoric acid, is measured in double FBG scheme that resulted in a significant increase in the sensitivity, and reduction of dead-zone.

  18. Towards highly sensitive strain sensing based on nanostructured materials

    International Nuclear Information System (INIS)

    Dao, Dzung Viet; Nakamura, Koichi; Sugiyama, Susumu; Bui, Tung Thanh; Dau, Van Thanh; Yamada, Takeo; Hata, Kenji

    2010-01-01

    This paper presents our recent theoretical and experimental study of piezo-effects in nanostructured materials for highly sensitive, high resolution mechanical sensors. The piezo-effects presented here include the piezoresistive effect in a silicon nanowire (SiNW) and single wall carbon nanotube (SWCNT) thin film, as well as the piezo-optic effect in a Si photonic crystal (PhC) nanocavity. Firstly, the electronic energy band structure of the silicon nanostructure is discussed and simulated by using the First-Principles Calculations method. The result showed a remarkably different energy band structure compared with that of bulk silicon. This difference in the electronic state will result in different physical, chemical, and therefore, sensing properties of silicon nanostructures. The piezoresistive effects of SiNW and SWCNT thin film were investigated experimentally. We found that, when the width of ( 110 ) p-type SiNW decreases from 500 to 35 nm, the piezoresistive effect increases by more than 60%. The longitudinal piezoresistive coefficient of SWCNT thin film was measured to be twice that of bulk p-type silicon. Finally, theoretical investigations of the piezo-optic effect in a PhC nanocavity based on Finite Difference Time Domain (FDTD) showed extremely high resolution strain sensing. These nanostructures were fabricated based on top-down nanofabrication technology. The achievements of this work are significant for highly sensitive, high resolution and miniaturized mechanical sensors

  19. Electrochemiluminescence assay of Cu2+ by using one-step electrodeposition synthesized CdS/ZnS quantum dots.

    Science.gov (United States)

    Zhao, Guanhui; Li, Xiaojian; Zhao, Yongbei; Li, Yueyuan; Cao, Wei; Wei, Qin

    2017-08-21

    A sensitive and selective method was proposed to detect Cu 2+ based on the electrochemiluminescence quenching of CdS/ZnS quantum dots (QDs). Herein, CdS/ZnS QDs were one-step electrodeposited directly on a gold electrode from an electrolyte (containing Cd(NO 3 ) 2 , Zn(NO 3 ) 2 , EDTA and Na 2 S 2 O 3 ) by cycling the potential from 0 to -1.8 V. The prepared CdS/ZnS QDs exhibited excellent solubility and strong and stable cathodic ECL activity. Meanwhile, Nafion was used to immobilize CdS/ZnS QDs. The quenching effect of Cu 2+ on the cathodic ECL of CdS/ZnS QDs was found to be selective and concentration dependent. The linear range for Cu 2+ detection was from 2.5 nM to 200 nM with a detection limit of 0.95 nM. Furthermore, the designed method for the detection of Cu 2+ can provide a reference for the detection of other heavy metal ions.

  20. Capillary electrophoresis coupled with electrochemiluminescence for determination of atomoxetine hydrochloride and the study on its interactions with three proteins.

    Science.gov (United States)

    Zeng, Hua-jin; Yang, Ran; Zhang, Ying; Li, Jian-jun; Qu, Ling-bo

    2015-03-01

    A simple, rapid and sensitive method for the determination of atomoxetine hydrochloride (AH) by capillary electrophoresis with electrochemiluminescence detection (CE-ECL) using tris(2,2'-bipyridyl) ruthenium (II) was developed. Under optimized conditions, the determinations of AH in capsules and rat plasmas and the study on its interactions with three plasma proteins, including bovine serum albumin, cytochrome c and myoglobin were performed successfully. Relative to some previous studies, in this paper the methodologies for the determination of AH in aqueous solution and spiked plasma systems were established, respectively. By comparing the difference between the two work curves of two systems, the matrix effect in plasma samples on the determination of AH by the CE-ECL method was discussed in detail. The results indicated that the effect of the matrix in plasma samples should not be ignored even if no obvious interference was found in the electropherograms and the establishment of method validation in complex samples by the CE-ECL method was necessary. Copyright © 2014 John Wiley & Sons, Ltd.

  1. Electrochemiluminescent pH sensor measured by the emission potential of TiO2 nanocrystals and its biosensing application.

    Science.gov (United States)

    Liu, Xuan; Wang, Nianyue; Zhao, Wei; Jiang, Hui

    2015-02-01

    This work reports for the first time a potential-based nano-electrochemiluminescent (ECL) pH sensor, using anatase TiO2 nanocrystals (NCs) as the ECL probe. The first ECL peak potential of the TiO2 NCs shifted negatively with increasing pH, showing a linear range from -0.47 V (vs Ag/AgCl) at pH 3 to -1.06 V at pH 10. This phenomenon was attributed to the absorption of 'potential-determining ions' of OH(-) on the surface of TiO2 NCs, leading to larger impedance of the electron injection. Other common 'potential-determining ions', such as phosphate, induced a slight potential shift of 0.03 V at a concentration of 0.1 M. Using urease as an enzyme model, a urea biosensor was developed by the simultaneous modification of urease and TiO2 NCs on indium-tin oxide (ITO) electrodes. The biosensor, measured on the basis of the pH increase caused by the enzyme catalysis reaction, had a linear range of 0.01-2.0 mM, with a potential shift of 0.175 V. The as-prepared pH sensor, which has simple construction procedures and acceptable sensitivity and selectivity, may provide new avenues for the construction of ECL bioanalytical methodologies. Copyright © 2014 John Wiley & Sons, Ltd.

  2. Ultrasonic microdialysis coupled with capillary electrophoresis electrochemiluminescence study the interaction between trimetazidine dihydrochloride and human serum albumin.

    Science.gov (United States)

    Sun, Shuangjiao; Long, Chanjuan; Tao, Chunyao; Meng, Sa; Deng, Biyang

    2014-12-03

    The paper describes a homemade ultrasonic microdialysis device coupled with capillary electrophoresis electrochemiluminescence (CE-ECL) for studying the interaction between human serum albumin (HSA) and trimetazidine dihydrochloride (TMZ). The time required for equilibrium by ultrasonic microdialysis was 45min, which was far less than that by traditional dialysis (240min). It took 80min to achieve the required combination equilibrium by normal incubation and only 20min by ultrasonic. Compared with traditional dialysis, the use of ultrasonic microdialysis simplified experimental procedures, shortened experimental time and saved consumption of sample. A simple, sensitive and selective determination of TMZ was developed using CE-ECL and the parameters that affected ECL intensity were optimized. Under the optimized conditions, the linear range of TMZ was from 0.075 to 80μmol/L (r(2)=0.9974). The detection limit was 26nmol/L with RSD of 2.8%. The number of binding sites and binding constant were 1.54 and 15.17L/mol, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. High sensitivity tests of the standard model for electroweak interactions

    International Nuclear Information System (INIS)

    Koetke, D.D.

    1992-01-01

    The work done on this project was focussed mainly on LAMPF experiment E969 known as the MEGA experiment, a high sensitivity search for the lepton family number violating decay μ → eγ to a sensitivity which, measured in terms of the branching ratio, BR = [μ→eγ]/[μ→e ν μ ν e ] ∼10 -13 is over two orders of magnitude better than previously reported values. The work done on MEGA during this period was divided between that done at Valparaiso University and that done at LAMPF. In addition, some contributions were made to a proposal to the LAMPF PAC to perform a precision measurement of the Michel ρ parameter, described below

  4. High sensitivity tests of the standard model for electroweak interactions

    International Nuclear Information System (INIS)

    1994-01-01

    The work done on this project focused on two LAMPF experiments. The MEGA experiment is a high-sensitivity search for the lepton family number violating decay μ → eγ to a sensitivity which, measured in terms of the branching ratio, BR = [μ → eγ]/[μ eν μ ν e ] ∼ 10 -13 , will be over two orders of magnitude better than previously reported values. The second is a precision measurement of the Michel ρ parameter from the positron energy spectrum of μ → eν μ ν e to test the predictions V-A theory of weak interactions. In this experiment the uncertainty in the measurement of the Michel ρ parameter is expected to be a factor of three lower than the present reported value. The detectors are operational, and data taking has begun

  5. High sensitivity tests of the standard model for electroweak interactions

    International Nuclear Information System (INIS)

    Koetke, D.D.; Manweiler, R.W.; Shirvel Stanislaus, T.D.

    1993-01-01

    The work done on this project was focused on two LAMPF experiments. The MEGA experiment, a high-sensitivity search for the lepton-family-number-violating decay μ → e γ to a sensitivity which, measured in terms of the branching ratio, BR = [μ → e γ]/[μ → ev μ v e ] ∼ 10 -13 , is over two orders of magnitude better than previously reported values. The second is a precision measurement of the Michel ρ parameter from the positron energy spectrum of μ → ev μ v e to test the V-A theory of weak interactions. The uncertainty in the measurement of the Michel ρ parameter is expected to be a factor of three lower than the present reported value

  6. High sensitive quench detection method using an integrated test wire

    International Nuclear Information System (INIS)

    Fevrier, A.; Tavergnier, J.P.; Nithart, H.; Kiblaire, M.; Duchateau, J.L.

    1981-01-01

    A high sensitive quench detection method which works even in the presence of an external perturbing magnetic field is reported. The quench signal is obtained from the difference in voltages at the superconducting winding terminals and at the terminals at a secondary winding strongly coupled to the primary. The secondary winding could consist of a ''zero-current strand'' of the superconducting cable not connected to one of the winding terminals or an integrated normal test wire inside the superconducting cable. Experimental results on quench detection obtained by this method are described. It is shown that the integrated test wire method leads to efficient and sensitive quench detection, especially in the presence of an external perturbing magnetic field

  7. Development of miniature γ dose rate monitor with high sensitivity

    International Nuclear Information System (INIS)

    Shi Huilu; Tuo Xianguo; Xi Dashun; Tang Rong; Mu Keliang; Yang Jianbo

    2009-01-01

    This paper introduces a miniature γ dose rate monitor with high sensitivity which design based on single chip microcomputer, it can continue monitoring γ dose rate and then choose wire or wireless communications to sent the monitoring data to host according to the actual conditions. It has two kinds of power supply system, AC power supply system and battery which can be chose by concrete circumstances. The design idea and implementation technology of hardware and software and the system structure of the monitor are detailed illustrated in this paper. The experimental results show that measurable range is 0.1 mR/h-200 mR/h, the sensitivity of γ is 90 cps/mR/h, dead time below 200 us, error of stability below ±10%. (authors)

  8. Polymer-Particle Pressure-Sensitive Paint with High Photostability

    Directory of Open Access Journals (Sweden)

    Yu Matsuda

    2016-04-01

    Full Text Available We propose a novel fast-responding and paintable pressure-sensitive paint (PSP based on polymer particles, i.e. polymer-particle (pp-PSP. As a fast-responding PSP, polymer-ceramic (PC-PSP is widely studied. Since PC-PSP generally consists of titanium (IV oxide (TiO2 particles, a large reduction in the luminescent intensity will occur due to the photocatalytic action of TiO2. We propose the usage of polymer particles instead of TiO2 particles to prevent the reduction in the luminescent intensity. Here, we fabricate pp-PSP based on the polystyrene particle with a diameter of 1 μm, and investigate the pressure- and temperature-sensitives, the response time, and the photostability. The performances of pp-PSP are compared with those of PC-PSP, indicating the high photostability with the other characteristics comparable to PC-PSP.

  9. Field test investigation of high sensitivity fiber optic seismic geophone

    Science.gov (United States)

    Wang, Meng; Min, Li; Zhang, Xiaolei; Zhang, Faxiang; Sun, Zhihui; Li, Shujuan; Wang, Chang; Zhao, Zhong; Hao, Guanghu

    2017-10-01

    Seismic reflection, whose measured signal is the artificial seismic waves ,is the most effective method and widely used in the geophysical prospecting. And this method can be used for exploration of oil, gas and coal. When a seismic wave travelling through the Earth encounters an interface between two materials with different acoustic impedances, some of the wave energy will reflect off the interface and some will refract through the interface. At its most basic, the seismic reflection technique consists of generating seismic waves and measuring the time taken for the waves to travel from the source, reflect off an interface and be detected by an array of geophones at the surface. Compared to traditional geophones such as electric, magnetic, mechanical and gas geophone, optical fiber geophones have many advantages. Optical fiber geophones can achieve sensing and signal transmission simultaneously. With the development of fiber grating sensor technology, fiber bragg grating (FBG) is being applied in seismic exploration and draws more and more attention to its advantage of anti-electromagnetic interference, high sensitivity and insensitivity to meteorological conditions. In this paper, we designed a high sensitivity geophone and tested its sensitivity, based on the theory of FBG sensing. The frequency response range is from 10 Hz to 100 Hz and the acceleration of the fiber optic seismic geophone is over 1000pm/g. sixteen-element fiber optic seismic geophone array system is presented and the field test is performed in Shengli oilfield of China. The field test shows that: (1) the fiber optic seismic geophone has a higher sensitivity than the traditional geophone between 1-100 Hz;(2) The low frequency reflection wave continuity of fiber Bragg grating geophone is better.

  10. A CMOS In-Pixel CTIA High Sensitivity Fluorescence Imager.

    Science.gov (United States)

    Murari, Kartikeya; Etienne-Cummings, Ralph; Thakor, Nitish; Cauwenberghs, Gert

    2011-10-01

    Traditionally, charge coupled device (CCD) based image sensors have held sway over the field of biomedical imaging. Complementary metal oxide semiconductor (CMOS) based imagers so far lack sensitivity leading to poor low-light imaging. Certain applications including our work on animal-mountable systems for imaging in awake and unrestrained rodents require the high sensitivity and image quality of CCDs and the low power consumption, flexibility and compactness of CMOS imagers. We present a 132×124 high sensitivity imager array with a 20.1 μm pixel pitch fabricated in a standard 0.5 μ CMOS process. The chip incorporates n-well/p-sub photodiodes, capacitive transimpedance amplifier (CTIA) based in-pixel amplification, pixel scanners and delta differencing circuits. The 5-transistor all-nMOS pixel interfaces with peripheral pMOS transistors for column-parallel CTIA. At 70 fps, the array has a minimum detectable signal of 4 nW/cm(2) at a wavelength of 450 nm while consuming 718 μA from a 3.3 V supply. Peak signal to noise ratio (SNR) was 44 dB at an incident intensity of 1 μW/cm(2). Implementing 4×4 binning allowed the frame rate to be increased to 675 fps. Alternately, sensitivity could be increased to detect about 0.8 nW/cm(2) while maintaining 70 fps. The chip was used to image single cell fluorescence at 28 fps with an average SNR of 32 dB. For comparison, a cooled CCD camera imaged the same cell at 20 fps with an average SNR of 33.2 dB under the same illumination while consuming over a watt.

  11. Highly sensitive detection of urinary cadmium to assess personal exposure

    Energy Technology Data Exchange (ETDEWEB)

    Argun, Avni A.; Banks, Ashley M.; Merlen, Gwendolynne; Tempelman, Linda A. [Giner, Inc., 89 Rumford Ave., Newton 02466, MA United States (United States); Becker, Michael F.; Schuelke, Thomas [Fraunhofer USA – CCL, 1449 Engineering Research Ct., East Lansing 48824, MI (United States); Dweik, Badawi M., E-mail: bdweik@ginerinc.com [Giner, Inc., 89 Rumford Ave., Newton 02466, MA United States (United States)

    2013-04-22

    Highlights: ► An electrochemical sensor capable of detecting cadmium at parts-per-billion levels in urine. ► A novel fabrication method for Boron-Doped Diamond (BDD) ultramicroelectrode (UME) arrays. ► Unique combination of BDD UME arrays and a differential pulse voltammetry algorithm. ► High sensitivity, high reproducibility, and very low noise levels. ► Opportunity for portable operation to assess on-site personal exposure. -- Abstract: A series of Boron-Doped Diamond (BDD) ultramicroelectrode arrays were fabricated and investigated for their performance as electrochemical sensors to detect trace level metals such as cadmium. The steady-state diffusion behavior of these sensors was validated using cyclic voltammetry followed by electrochemical detection of cadmium in water and in human urine to demonstrate high sensitivity (>200 μA ppb{sup −1} cm{sup −2}) and low background current (<4 nA). When an array of ultramicroelectrodes was positioned with optimal spacing, these BDD sensors showed a sigmoidal diffusion behavior. They also demonstrated high accuracy with linear dose dependence for quantification of cadmium in a certified reference river water sample from the U.S. National Institute of Standards and Technology (NIST) as well as in a human urine sample spiked with 0.25–1 ppb cadmium.

  12. High order effects in cross section sensitivity analysis

    International Nuclear Information System (INIS)

    Greenspan, E.; Karni, Y.; Gilai, D.

    1978-01-01

    Two types of high order effects associated with perturbations in the flux shape are considered: Spectral Fine Structure Effects (SFSE) and non-linearity between changes in performance parameters and data uncertainties. SFSE are investigated in Part I using a simple single resonance model. Results obtained for each of the resolved and for representative unresolved resonances of 238 U in a ZPR-6/7 like environment indicate that SFSE can have a significant contribution to the sensitivity of group constants to resonance parameters. Methods to account for SFSE both for the propagation of uncertainties and for the adjustment of nuclear data are discussed. A Second Order Sensitivity Theory (SOST) is presented, and its accuracy relative to that of the first order sensitivity theory and of the direct substitution method is investigated in Part II. The investigation is done for the non-linear problem of the effect of changes in the 297 keV sodium minimum cross section on the transport of neutrons in a deep-penetration problem. It is found that the SOST provides a satisfactory accuracy for cross section uncertainty analysis. For the same degree of accuracy, the SOST can be significantly more efficient than the direct substitution method

  13. Operationalization of the Russian Version of Highly Sensitive Person Scale

    Directory of Open Access Journals (Sweden)

    Регина Вячеславовна Ершова

    2018-12-01

    Full Text Available The aim of the present study was to operationalize a Russian version of the Highly Sensitive Person Scale (HSPS. The empirical data were collected in two ways: active, through oral advertising and inviting those who wish to take part in the study (snowball technique and passive (placement of ads about taking part in a research in social networks VKontakte and Facebook. As a result, 350 university students (117 men, 233 women, an average age of 18,2 (± 1,7 applied to a research laboratory and filled out the HSPS questionnaire, and another 510 respondents (380 women, 130 men, average age 22,6 ( ± 7,9 filled the HSPS online. The results of the study did not confirm the one-dimensional model of the construct, proposed by Aron & Aron (1997, as well as the most commonly used in the English-language studies three-factor solution. The hierarchical claster and confirmatory analyses used in the operationalization procedure allowed us to conclude that the variance of the Russian version of HSPS is best described in the framework of a two-factor model including the two separate subscales: Ease of Excitation (EOE, Low threshold of sensitivity (LTS. Sensory Processing Sensitivity may be defined as an increased susceptibility to external and internal stimuli, realized through negative emotional responses and deep susceptibility (distress to excessive stimulation.

  14. A wide-bandwidth and high-sensitivity robust microgyroscope

    International Nuclear Information System (INIS)

    Sahin, Korhan; Sahin, Emre; Akin, Tayfun; Alper, Said Emre

    2009-01-01

    This paper reports a microgyroscope design concept with the help of a 2 degrees of freedom (DoF) sense mode to achieve a wide bandwidth without sacrificing mechanical and electronic sensitivity and to obtain robust operation against variations under ambient conditions. The design concept is demonstrated with a tuning fork microgyroscope fabricated with an in-house silicon-on-glass micromachining process. When the fabricated gyroscope is operated with a relatively wide bandwidth of 1 kHz, measurements show a relatively high raw mechanical sensitivity of 131 µV (° s −1 ) −1 . The variation in the amplified mechanical sensitivity (scale factor) of the gyroscope is measured to be less than 0.38% for large ambient pressure variations such as from 40 to 500 mTorr. The bias instability and angle random walk of the gyroscope are measured to be 131° h −1 and 1.15° h −1/2 , respectively

  15. Development of an underwater high sensitivity Cherenkov detector: Sea Urchin

    International Nuclear Information System (INIS)

    Camerini, U.; McGibney, D.; Roberts, A.

    1982-01-01

    The need for a high gain, high sensitivity Cherenkov light sensor to be used in a deep underwater muon and neutrino detector (DUMAND) array has led to the design of the Sea Urchin detector. In this design a spherical photocathode PMTis optically coupled through a glass hemisphere to a large number of glass spines, each of which is filled with a wavelength-shifting (WLS) solution of a high quantum efficiency phosphor. The Cherenkov radiation is absorbed in the spine, isotropically re-radiated at a longer wavelength, and a fraction of the fluorescent light is internally reflected in the spine, and guided to the photomultiplier concentrically located in the glass hemisphere. Experiments measuring the optical characteristics of the spines and computer programs simulating light transformation and detection cross sections are described. Overall optical gains in the range 5-10 are achieved. The WLS solution is inexpensive, and may have other applications. (orig.)

  16. Position sensitive detection of neutrons in high radiation background field.

    Science.gov (United States)

    Vavrik, D; Jakubek, J; Pospisil, S; Vacik, J

    2014-01-01

    We present the development of a high-resolution position sensitive device for detection of slow neutrons in the environment of extremely high γ and e(-) radiation background. We make use of a planar silicon pixelated (pixel size: 55 × 55 μm(2)) spectroscopic Timepix detector adapted for neutron detection utilizing very thin (10)B converter placed onto detector surface. We demonstrate that electromagnetic radiation background can be discriminated from the neutron signal utilizing the fact that each particle type produces characteristic ionization tracks in the pixelated detector. Particular tracks can be distinguished by their 2D shape (in the detector plane) and spectroscopic response using single event analysis. A Cd sheet served as thermal neutron stopper as well as intensive source of gamma rays and energetic electrons. Highly efficient discrimination was successful even at very low neutron to electromagnetic background ratio about 10(-4).

  17. Highly Sensitive Flexible Magnetic Sensor Based on Anisotropic Magnetoresistance Effect.

    Science.gov (United States)

    Wang, Zhiguang; Wang, Xinjun; Li, Menghui; Gao, Yuan; Hu, Zhongqiang; Nan, Tianxiang; Liang, Xianfeng; Chen, Huaihao; Yang, Jia; Cash, Syd; Sun, Nian-Xiang

    2016-11-01

    A highly sensitive flexible magnetic sensor based on the anisotropic magnetoresistance effect is fabricated. A limit of detection of 150 nT is observed and excellent deformation stability is achieved after wrapping of the flexible sensor, with bending radii down to 5 mm. The flexible AMR sensor is used to read a magnetic pattern with a thickness of 10 μm that is formed by ferrite magnetic inks. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. High sensitivity on-line monitor for radioactive effluent

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Toshimi [Tohoku Electric Power Co. Ltd., Sendai (Japan); Ishizuka, Akira; Abe, Eisuke; Inoue, Yasuhiko; Fujii, Masaaki; Kitaguchi, Hiroshi; Doi, Akira

    1983-04-01

    A new approach for a highly sensitive effluent monitor is presented. The free flow type monitor, which consists of a straightener, nozzle, monitoring section and ..gamma..-ray detector, is demonstrated to be effective in providing long term stability. The 160 start-and-stop cycles of effluent discharge were repeated in a 120-h testing period. Results showed a background increase was not observed for the free flow type monitor. The background count rate was calibrated to the lowest detection limit to be 2.2 x 10/sup -2/ Bq/ml for a 300 s measurement time.

  19. High-Sensitivity Measurement of Density by Magnetic Levitation.

    Science.gov (United States)

    Nemiroski, Alex; Kumar, A A; Soh, Siowling; Harburg, Daniel V; Yu, Hai-Dong; Whitesides, George M

    2016-03-01

    This paper presents methods that use Magnetic Levitation (MagLev) to measure very small differences in density of solid diamagnetic objects suspended in a paramagnetic medium. Previous work in this field has shown that, while it is a convenient method, standard MagLev (i.e., where the direction of magnetization and gravitational force are parallel) cannot resolve differences in density mm) because (i) objects close in density prevent each other from reaching an equilibrium height due to hard contact and excluded volume, and (ii) using weaker magnets or reducing the magnetic susceptibility of the medium destabilizes the magnetic trap. The present work investigates the use of weak magnetic gradients parallel to the faces of the magnets as a means of increasing the sensitivity of MagLev without destabilization. Configuring the MagLev device in a rotated state (i.e., where the direction of magnetization and gravitational force are perpendicular) relative to the standard configuration enables simple measurements along the axes with the highest sensitivity to changes in density. Manipulating the distance of separation between the magnets or the lengths of the magnets (along the axis of measurement) enables the sensitivity to be tuned. These modifications enable an improvement in the resolution up to 100-fold over the standard configuration, and measurements with resolution down to 10(-6) g/cm(3). Three examples of characterizing the small differences in density among samples of materials having ostensibly indistinguishable densities-Nylon spheres, PMMA spheres, and drug spheres-demonstrate the applicability of rotated Maglev to measuring the density of small (0.1-1 mm) objects with high sensitivity. This capability will be useful in materials science, separations, and quality control of manufactured objects.

  20. High pressure-sensitive gene expression in Lactobacillus sanfranciscensis

    Directory of Open Access Journals (Sweden)

    R.F. Vogel

    2005-08-01

    Full Text Available Lactobacillus sanfranciscensis is a Gram-positive lactic acid bacterium used in food biotechnology. It is necessary to investigate many aspects of a model organism to elucidate mechanisms of stress response, to facilitate preparation, application and performance in food fermentation, to understand mechanisms of inactivation, and to identify novel tools for high pressure biotechnology. To investigate the mechanisms of the complex bacterial response to high pressure we have analyzed changes in the proteome and transcriptome by 2-D electrophoresis, and by microarrays and real time PCR, respectively. More than 16 proteins were found to be differentially expressed upon high pressure stress and were compared to those sensitive to other stresses. Except for one apparently high pressure-specific stress protein, no pressure-specific stress proteins were found, and the proteome response to pressure was found to differ from that induced by other stresses. Selected pressure-sensitive proteins were partially sequenced and their genes were identified by reverse genetics. In a transcriptome analysis of a redundancy cleared shot gun library, about 7% of the genes investigated were found to be affected. Most of them appeared to be up-regulated 2- to 4-fold and these results were confirmed by real time PCR. Gene induction was shown for some genes up-regulated at the proteome level (clpL/groEL/rbsK, while the response of others to high hydrostatic pressure at the transcriptome level seemed to differ from that observed at the proteome level. The up-regulation of selected genes supports the view that the cell tries to compensate for pressure-induced impairment of translation and membrane transport.

  1. A simple, tunable, and highly sensitive radio-frequency sensor.

    Science.gov (United States)

    Cui, Yan; Sun, Jiwei; He, Yuxi; Wang, Zheng; Wang, Pingshan

    2013-08-05

    We report a radio frequency (RF) sensor that exploits tunable attenuators and phase shifters to achieve high-sensitivity and broad band frequency tunability. Three frequency bands are combined to enable sensor operations from ∼20 MHz to ∼38 GHz. The effective quality factor ( Q eff ) of the sensor is as high as ∼3.8 × 10 6 with 200  μ l of water samples. We also demonstrate the measurement of 2-proponal-water-solution permittivity at 0.01 mole concentration level from ∼1 GHz to ∼10 GHz. Methanol-water solution and de-ionized water are used to calibrate the RF sensor for the quantitative measurements.

  2. Correcting systematic errors in high-sensitivity deuteron polarization measurements

    Science.gov (United States)

    Brantjes, N. P. M.; Dzordzhadze, V.; Gebel, R.; Gonnella, F.; Gray, F. E.; van der Hoek, D. J.; Imig, A.; Kruithof, W. L.; Lazarus, D. M.; Lehrach, A.; Lorentz, B.; Messi, R.; Moricciani, D.; Morse, W. M.; Noid, G. A.; Onderwater, C. J. G.; Özben, C. S.; Prasuhn, D.; Levi Sandri, P.; Semertzidis, Y. K.; da Silva e Silva, M.; Stephenson, E. J.; Stockhorst, H.; Venanzoni, G.; Versolato, O. O.

    2012-02-01

    This paper reports deuteron vector and tensor beam polarization measurements taken to investigate the systematic variations due to geometric beam misalignments and high data rates. The experiments used the In-Beam Polarimeter at the KVI-Groningen and the EDDA detector at the Cooler Synchrotron COSY at Jülich. By measuring with very high statistical precision, the contributions that are second-order in the systematic errors become apparent. By calibrating the sensitivity of the polarimeter to such errors, it becomes possible to obtain information from the raw count rate values on the size of the errors and to use this information to correct the polarization measurements. During the experiment, it was possible to demonstrate that corrections were satisfactory at the level of 10 -5 for deliberately large errors. This may facilitate the real time observation of vector polarization changes smaller than 10 -6 in a search for an electric dipole moment using a storage ring.

  3. Correcting systematic errors in high-sensitivity deuteron polarization measurements

    Energy Technology Data Exchange (ETDEWEB)

    Brantjes, N.P.M. [Kernfysisch Versneller Instituut, University of Groningen, NL-9747AA Groningen (Netherlands); Dzordzhadze, V. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Gebel, R. [Institut fuer Kernphysik, Juelich Center for Hadron Physics, Forschungszentrum Juelich, D-52425 Juelich (Germany); Gonnella, F. [Physica Department of ' Tor Vergata' University, Rome (Italy); INFN-Sez. ' Roma tor Vergata,' Rome (Italy); Gray, F.E. [Regis University, Denver, CO 80221 (United States); Hoek, D.J. van der [Kernfysisch Versneller Instituut, University of Groningen, NL-9747AA Groningen (Netherlands); Imig, A. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Kruithof, W.L. [Kernfysisch Versneller Instituut, University of Groningen, NL-9747AA Groningen (Netherlands); Lazarus, D.M. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Lehrach, A.; Lorentz, B. [Institut fuer Kernphysik, Juelich Center for Hadron Physics, Forschungszentrum Juelich, D-52425 Juelich (Germany); Messi, R. [Physica Department of ' Tor Vergata' University, Rome (Italy); INFN-Sez. ' Roma tor Vergata,' Rome (Italy); Moricciani, D. [INFN-Sez. ' Roma tor Vergata,' Rome (Italy); Morse, W.M. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Noid, G.A. [Indiana University Cyclotron Facility, Bloomington, IN 47408 (United States); and others

    2012-02-01

    This paper reports deuteron vector and tensor beam polarization measurements taken to investigate the systematic variations due to geometric beam misalignments and high data rates. The experiments used the In-Beam Polarimeter at the KVI-Groningen and the EDDA detector at the Cooler Synchrotron COSY at Juelich. By measuring with very high statistical precision, the contributions that are second-order in the systematic errors become apparent. By calibrating the sensitivity of the polarimeter to such errors, it becomes possible to obtain information from the raw count rate values on the size of the errors and to use this information to correct the polarization measurements. During the experiment, it was possible to demonstrate that corrections were satisfactory at the level of 10{sup -5} for deliberately large errors. This may facilitate the real time observation of vector polarization changes smaller than 10{sup -6} in a search for an electric dipole moment using a storage ring.

  4. Wide bandwidth transimpedance amplifier for extremely high sensitivity continuous measurements.

    Science.gov (United States)

    Ferrari, Giorgio; Sampietro, Marco

    2007-09-01

    This article presents a wide bandwidth transimpedance amplifier based on the series of an integrator and a differentiator stage, having an additional feedback loop to discharge the standing current from the device under test (DUT) to ensure an unlimited measuring time opportunity when compared to switched discharge configurations while maintaining a large signal amplification over the full bandwidth. The amplifier shows a flat response from 0.6 Hz to 1.4 MHz, the capability to operate with leakage currents from the DUT as high as tens of nanoamperes, and rail-to-rail dynamic range for sinusoidal current signals independent of the DUT leakage current. Also available is a monitor output of the stationary current to track experimental slow drifts. The circuit is ideal for noise spectral and impedance measurements of nanodevices and biomolecules when in the presence of a physiological medium and in all cases where high sensitivity current measurements are requested such as in scanning probe microscopy systems.

  5. Design of a charge sensitive preamplifier on high resistivity silicon

    International Nuclear Information System (INIS)

    Radeka, V.; Rehak, P.; Rescia, S.; Gatti, E.; Longoni, A.; Sampietro, M.; Holl, P.; Strueder, L.; Kemmer, J.

    1987-01-01

    A low noise, fast charge sensitive preamplifier was designed on high resistivity, detector grade silicon. It is built at the surface of a fully depleted region of n-type silicon. This allows the preamplifier to be placed very close to a detector anode. The preamplifier uses the classical input cascode configuration with a capacitor and a high value resistor in the feedback loop. The output stage of the preamplifier can drive a load up to 20pF. The power dissipation of the preamplifier is 13mW. The amplifying elements are ''Single Sided Gate JFETs'' developed especially for this application. Preamplifiers connected to a low capacitance anode of a drift type detector should achieve a rise time of 20ns and have an equivalent noise charge (ENC), after a suitable shaping, of less than 50 electrons. This performance translates to a position resolution better than 3μm for silicon drift detectors. 6 refs., 9 figs

  6. High-Sensitivity Temperature-Independent Silicon Photonic Microfluidic Biosensors

    Science.gov (United States)

    Kim, Kangbaek

    Optical biosensors that can precisely quantify the presence of specific molecular species in real time without the need for labeling have seen increased use in the drug discovery industry and molecular biology in general. Of the many possible optical biosensors, the TM mode Si biosensor is shown to be very attractive in the sensing application because of large field amplitude on the surface and cost effective CMOS VLSI fabrication. Noise is the most fundamental factor that limits the performance of sensors in development of high-sensitivity biosensors, and noise reduction techniques require precise studies and analysis. One such example stems from thermal fluctuations. Generally SOI biosensors are vulnerable to ambient temperature fluctuations because of large thermo-optic coefficient of silicon (˜2x10 -4 RIU/K), typically requiring another reference ring and readout sequence to compensate temperature induced noise. To address this problem, we designed sensors with a novel TM-mode shallow-ridge waveguide that provides both large surface amplitude for bulk and surface sensing. With proper design, this also provides large optical confinement in the aqueous cladding that renders the device athermal using the negative thermo-optic coefficient of water (~ --1x10-4RIU/K), demonstrating cancellation of thermo-optic effects for aqueous solution operation near 300K. Additional limitations resulting from mechanical actuator fluctuations, stability of tunable lasers, and large 1/f noise of lasers and sensor electronics can limit biosensor performance. Here we also present a simple harmonic feedback readout technique that obviates the need for spectrometers and tunable lasers. This feedback technique reduces the impact of 1/f noise to enable high-sensitivity, and a DSP lock-in with 256 kHz sampling rate can provide down to micros time scale monitoring for fast transitions in biomolecular concentration with potential for small volume and low cost. In this dissertation, a novel

  7. High sensitivity pyrogen testing in water and dialysis solutions.

    Science.gov (United States)

    Daneshian, Mardas; Wendel, Albrecht; Hartung, Thomas; von Aulock, Sonja

    2008-07-20

    The dialysis patient is confronted with hundreds of litres of dialysis solution per week, which pass the natural protective barriers of the body and are brought into contact with the tissue directly in the case of peritoneal dialysis or indirectly in the case of renal dialysis (hemodialysis). The components can be tested for living specimens or dead pyrogenic (fever-inducing) contaminations. The former is usually detected by cultivation and the latter by the endotoxin-specific Limulus Amoebocyte Lysate Assay (LAL). However, the LAL assay does not reflect the response of the human immune system to the wide variety of possible pyrogenic contaminations in dialysis fluids. Furthermore, the test is limited in its sensitivity to detect extremely low concentrations of pyrogens, which in their sum result in chronic pathologies in dialysis patients. The In vitro Pyrogen Test (IPT) employs human whole blood to detect the spectrum of pyrogens to which humans respond by measuring the release of the endogenous fever mediator interleukin-1beta. Spike recovery checks exclude interference. The test has been validated in an international study for pyrogen detection in injectable solutions. In this study we adapted the IPT to the testing of dialysis solutions. Preincubation of 50 ml spiked samples with albumin-coated microspheres enhanced the sensitivity of the assay to detect contaminations down to 0.1 pg/ml LPS or 0.001 EU/ml in water or saline and allowed pyrogen detection in dialysis concentrates or final working solutions. This method offers high sensitivity detection of human-relevant pyrogens in dialysis solutions and components.

  8. A reagentless electrochemiluminescent immunosensor for apurinic/apyrimidinic endonuclease 1 detection based on the new Ru(bpy){sub 3}{sup 2+}/bi-arginine system

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Min; Chai, Xi Deng Ya-Qin; Han, Jing; Gui, Guo-Feng; Yuan, Ruo, E-mail: yuanruo@swu.edu.cn; Zhuo, Ying, E-mail: yingzhuo@swu.edu.cn

    2014-10-10

    Highlights: • A reagentless ECL biosensor based on the new Ru(bpy){sub 3}{sup 2+}/bi-arginine system. • The successful preparation of bi-Arg/Au@Fe3O4–rGO as enhancer. • Using the APE-1 as target by the sandwich-type immunoassay format. - Abstract: Apurinic/apyrimidinic endonuclease 1 (APE-1), a kind of multifunctional protein widely-distributed in the body, plays an essential role in the DNA base excision repair and serves as multiple possible roles in the response of human cancer to radiotherapy and chemotherapy. In this work, an ultrasensitive solid-state electrochemiluminescence (ECL) immunosensor is designed to determine APE-1 based on the new Ru(bpy){sub 3}{sup 2+}/bi-arginine system. The bi-arginine (bi-Arg) is decorated on the Au nanoparticles functionalized magnetic Fe{sub 3}O{sub 4}/reduced graphene oxide (bi-Arg/Au@Fe{sub 3}O{sub 4}–rGO) according to the self-assembling and covalent cross-linking interaction to obtain the functionalized nanocomposite of bi-Arg/Au@Fe{sub 3}O{sub 4}–rGO. Herein, the bi-Arg/Au@Fe{sub 3}O{sub 4}–rGO plays not only an amplification label to enhance the ECL signal of Ru(bpy){sub 3}{sup 2+} due to the coreactant of bi-Arg but also an ideal nanocarrier to load numerous secondary antibody. Based on sandwich-type immunoassay format, this proposed method offers a linear range of 1.0 fg mL{sup −1}–5.0 pg mL{sup −1} and an estimated detection limit of 0.3 fg mL{sup −1} for the APE-1. Moreover, the reagentless ECL immunosensor also exhibits high sensitivity, excellent selectivity and good stability, which has greatly potential development and application in clinical diagnostics, immunology and biomedical research.

  9. Luminescent Lanthanide Reporters for High-Sensitivity Novel Bioassays

    Energy Technology Data Exchange (ETDEWEB)

    Anstey, Mitchell R. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Fruetel, Julia A. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Foster, Michael E. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Hayden, Carl C. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Buckley, Heather L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Arnold, John [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2013-09-01

    Biological imaging and assay technologies rely on fluorescent organic dyes as reporters for a number of interesting targets and processes. However, limitations of organic dyes such as small Stokes shifts, spectral overlap of emission signals with native biological fluorescence background, and photobleaching have all inhibited the development of highly sensitive assays. To overcome the limitations of organic dyes for bioassays, we propose to develop lanthanide-based luminescent dyes and demonstrate them for molecular reporting applications. This relatively new family of dyes was selected for their attractive spectral and chemical properties. Luminescence is imparted by the lanthanide atom and allows for relatively simple chemical structures that can be tailored to the application. The photophysical properties offer unique features such as narrow and non-overlapping emission bands, long luminescent lifetimes, and long wavelength emission, which enable significant sensitivity improvements over organic dyes through spectral and temporal gating of the luminescent signal.Growth in this field has been hindered due to the necessary advanced synthetic chemistry techniques and access to experts in biological assay development. Our strategy for the development of a new lanthanide-based fluorescent reporter system is based on chelation of the lanthanide metal center using absorbing chromophores. Our first strategy involves "Click" chemistry to develop 3-fold symmetric chelators and the other involves use of a new class of tetrapyrrole ligands called corroles. This two-pronged approach is geared towards the optimization of chromophores to enhance light output.

  10. New application of superconductors: High sensitivity cryogenic light detectors

    Energy Technology Data Exchange (ETDEWEB)

    Cardani, L., E-mail: laura.cardani@roma1.infn.it [Dipartimento di Fisica, Sapienza Università di Roma, Piazzale Aldo Moro 2, 00185 Roma (Italy); Physics Department, Princeton University, Washington Road, 08544 Princeton, NJ (United States); Bellini, F.; Casali, N. [Dipartimento di Fisica, Sapienza Università di Roma, Piazzale Aldo Moro 2, 00185 Roma (Italy); INFN – Sezione di Roma, Piazzale Aldo Moro 2, 00185 Roma, Italy (Italy); Castellano, M.G. [Istituto di Fotonica e Nanotecnologie – CNR, Via Cineto Romano 42, 00156 Roma (Italy); Colantoni, I.; Coppolecchia, A. [Dipartimento di Fisica, Sapienza Università di Roma, Piazzale Aldo Moro 2, 00185 Roma (Italy); Cosmelli, C.; Cruciani, A. [Dipartimento di Fisica, Sapienza Università di Roma, Piazzale Aldo Moro 2, 00185 Roma (Italy); INFN – Sezione di Roma, Piazzale Aldo Moro 2, 00185 Roma, Italy (Italy); D' Addabbo, A. [INFN – Laboratori Nazionali del Gran Sasso, Assergi (L' Aquila) 67010 (Italy); Di Domizio, S. [INFN – Sezione di Genova, Via Dodecaneso 33, 16146 Genova (Italy); Dipartimento di Fisica, Università degli Studi di Genova, Via Dodecaneso 33, 16146 Genova (Italy); Martinez, M. [Dipartimento di Fisica, Sapienza Università di Roma, Piazzale Aldo Moro 2, 00185 Roma (Italy); INFN – Sezione di Roma, Piazzale Aldo Moro 2, 00185 Roma, Italy (Italy); Laboratorio de Fisica Nuclear y Astroparticulas, Universidad de Zaragoza, Zaragoza 50009 (Spain); Tomei, C. [INFN – Sezione di Roma, Piazzale Aldo Moro 2, 00185 Roma, Italy (Italy); and others

    2017-02-11

    In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superconductor can break the Cooper pairs, causing sizable variations in the kinetic inductance and, thus, in the response of the LC circuit. The continuous monitoring of the amplitude and frequency modulation allows to reconstruct the incident energy with excellent sensitivity. This concept is at the basis of Kinetic Inductance Detectors (KIDs) that are characterized by natural aptitude to multiplexed read-out (several sensors can be tuned to different resonant frequencies and coupled to the same line), resolution of few eV, stable behavior over a wide temperature range, and ease in fabrication. We present the results obtained by the CALDER collaboration with 2×2 cm{sup 2} substrates sampled by 1 or 4 Aluminum KIDs. We show that the performances of the first prototypes are already competitive with those of other commonly used light detectors, and we discuss the strategies for a further improvement.

  11. New application of superconductors: High sensitivity cryogenic light detectors

    International Nuclear Information System (INIS)

    Cardani, L.; Bellini, F.; Casali, N.; Castellano, M.G.; Colantoni, I.; Coppolecchia, A.; Cosmelli, C.; Cruciani, A.; D'Addabbo, A.; Di Domizio, S.; Martinez, M.; Tomei, C.

    2017-01-01

    In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superconductor can break the Cooper pairs, causing sizable variations in the kinetic inductance and, thus, in the response of the LC circuit. The continuous monitoring of the amplitude and frequency modulation allows to reconstruct the incident energy with excellent sensitivity. This concept is at the basis of Kinetic Inductance Detectors (KIDs) that are characterized by natural aptitude to multiplexed read-out (several sensors can be tuned to different resonant frequencies and coupled to the same line), resolution of few eV, stable behavior over a wide temperature range, and ease in fabrication. We present the results obtained by the CALDER collaboration with 2×2 cm"2 substrates sampled by 1 or 4 Aluminum KIDs. We show that the performances of the first prototypes are already competitive with those of other commonly used light detectors, and we discuss the strategies for a further improvement.

  12. High-Sensitivity AGN Polarimetry at Sub-Millimeter Wavelengths

    Directory of Open Access Journals (Sweden)

    Ivan Martí-Vidal

    2017-10-01

    Full Text Available The innermost regions of radio loud Active Galactic Nuclei (AGN jets are heavily affected by synchrotron self-absorption, due to the strong magnetic fields and high particle densities in these extreme zones. The only way to overcome this absorption is to observe at sub-millimeter wavelengths, although polarimetric observations at such frequencies have so far been limited by sensitivity and calibration accuracy. However, new generation instruments such as the Atacama Large mm/sub-mm Array (ALMA overcome these limitations and are starting to deliver revolutionary results in the observational studies of AGN polarimetry. Here we present an overview of our state-of-the-art interferometric mm/sub-mm polarization observations of AGN jets with ALMA (in particular, the gravitationally-lensed sources PKS 1830−211 and B0218+359, which allow us to probe the magneto-ionic conditions at the regions closest to the central black holes.

  13. High resolution, position sensitive detector for energetic particle beams

    International Nuclear Information System (INIS)

    Marsh, E.P.; Strathman, M.D.; Reed, D.A.; Odom, R.W.; Morse, D.H.; Pontau, A.E.

    1993-01-01

    The performance and design of an imaging position sensitive, particle beam detector will be presented. The detector is minimally invasive, operates a wide dynamic range (>10 10 ), and exhibits high spatial resolution. The secondary electrons produced when a particle beam passes through a thin foil are imaged using stigmatic ion optics onto a two-dimensional imaging detector. Due to the low scattering cross section of the 6 nm carbon foil the detector is a minimal perturbation on the primary beam. A prototype detector with an image resolution of approximately 5 μm for a field of view of 1 mm has been reported. A higher resolution detector for imaging small beams (<50 μm) with an image resolution of better than 0.5 μm has since been developed and its design is presented. (orig.)

  14. High resolution, position sensitive detector for energetic particle beams

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, E P [Charles Evans and Associates, Redwood City, CA (United States); Strathman, M D [Charles Evans and Associates, Redwood City, CA (United States); Reed, D A [Charles Evans and Associates, Redwood City, CA (United States); Odom, R W [Charles Evans and Associates, Redwood City, CA (United States); Morse, D H [Sandia National Labs., Livermore, CA (United States); Pontau, A E [Sandia National Labs., Livermore, CA (United States)

    1993-05-01

    The performance and design of an imaging position sensitive, particle beam detector will be presented. The detector is minimally invasive, operates a wide dynamic range (>10[sup 10]), and exhibits high spatial resolution. The secondary electrons produced when a particle beam passes through a thin foil are imaged using stigmatic ion optics onto a two-dimensional imaging detector. Due to the low scattering cross section of the 6 nm carbon foil the detector is a minimal perturbation on the primary beam. A prototype detector with an image resolution of approximately 5 [mu]m for a field of view of 1 mm has been reported. A higher resolution detector for imaging small beams (<50 [mu]m) with an image resolution of better than 0.5 [mu]m has since been developed and its design is presented. (orig.)

  15. Highly Sensitive Filter Paper Substrate for SERS Trace Explosives Detection

    Directory of Open Access Journals (Sweden)

    Pedro M. Fierro-Mercado

    2012-01-01

    Full Text Available We report on a novel and extremely low-cost surface-enhanced Raman spectroscopy (SERS substrate fabricated depositing gold nanoparticles on common lab filter paper using thermal inkjet technology. The paper-based substrate combines all advantages of other plasmonic structures fabricated by more elaborate techniques with the dynamic flexibility given by the inherent nature of the paper for an efficient sample collection, robustness, and stability. We describe the fabrication, characterization, and SERS activity of our substrate using 2,4,6-trinitrotoluene, 2,4-dinitrotoluene, and 1,3,5-trinitrobenzene as analytes. The paper-based SERS substrates presented a high sensitivity and excellent reproducibility for analytes employed, demonstrating a direct application in forensic science and homeland security.

  16. High efficiency solid-state sensitized heterojunction photovoltaic device

    KAUST Repository

    Wang, Mingkui

    2010-06-01

    The high molar extinction coefficient heteroleptic ruthenium dye, NaRu(4,4′-bis(5-(hexylthio)thiophen-2-yl)-2,2′-bipyridine) (4-carboxylic acid-4′-carboxylate-2,2′-bipyridine) (NCS) 2, exhibits certified 5% electric power conversion efficiency at AM 1.5 solar irradiation (100 mW cm-2) in a solid-state dye-sensitized solar cell using 2,2′,7,7′-tetrakis-(N,N-di-pmethoxyphenylamine)-9, 9′-spirobifluorene (spiro-MeOTAD) as the organic hole-transporting material. This demonstration elucidates a class of photovoltaic devices with potential for low-cost power generation. © 2010 Elsevier Ltd. All rights reserved.

  17. High efficiency solid-state sensitized heterojunction photovoltaic device

    KAUST Repository

    Wang, Mingkui; Liu, Jingyuan; Cevey-Ha, Ngoc-Le; Moon, Soo-Jin; Liska, Paul; Humphry-Baker, Robin; Moser, Jacques-E.; Grä tzel, Carole; Wang, Peng; Zakeeruddin, Shaik M.

    2010-01-01

    The high molar extinction coefficient heteroleptic ruthenium dye, NaRu(4,4′-bis(5-(hexylthio)thiophen-2-yl)-2,2′-bipyridine) (4-carboxylic acid-4′-carboxylate-2,2′-bipyridine) (NCS) 2, exhibits certified 5% electric power conversion efficiency at AM 1.5 solar irradiation (100 mW cm-2) in a solid-state dye-sensitized solar cell using 2,2′,7,7′-tetrakis-(N,N-di-pmethoxyphenylamine)-9, 9′-spirobifluorene (spiro-MeOTAD) as the organic hole-transporting material. This demonstration elucidates a class of photovoltaic devices with potential for low-cost power generation. © 2010 Elsevier Ltd. All rights reserved.

  18. Effective dose calculation in CT using high sensitivity TLDs

    International Nuclear Information System (INIS)

    Brady, Z.; Johnston, P.N.

    2010-01-01

    Full text: To determine the effective dose for common paediatric CT examinations using thermoluminescence dosimetry (TLD) mea surements. High sensitivity TLD chips (LiF:Mg,Cu,P, TLD-IOOH, Thermo Fisher Scientific, Waltham, MA) were calibrated on a linac at an energy of 6 MY. A calibration was also performed on a superricial X-ray unit at a kilovoltage energy to validate the megavoltage cali bration for the purpose of measuring doses in the diagnostic energy range. The dose variation across large organs was assessed and a methodology for TLD placement in a 10 year old anthropomorphic phantom developed. Effective dose was calculated from the TLD measured absorbed doses for typical CT examinations after correcting for the TLD energy response and taking into account differences in the mass energy absorption coefficients for different tissues and organs. Results Using new tissue weighting factors recommended in ICRP Publication 103, the effective dose for a CT brain examination on a 10 year old was 1.6 millisieverts (mSv), 4.9 mSv for a CT chest exa ination and 4.7 mSv for a CT abdomen/pelvis examination. These values are lower for the CT brain examination, higher for the CT chest examination and approximately the same for the CT abdomen/ pelvis examination when compared with effective doses calculated using ICRP Publication 60 tissue weighting factors. Conclusions High sensitivity TLDs calibrated with a radiotherapy linac are useful for measuring dose in the diagnostic energy range and overcome limitations of output reproducibility and uniformity asso ciated with traditional TLD calibration on CT scanners or beam quality matched diagnostic X-ray units.

  19. Zinc-doping enhanced cadmium sulfide electrochemiluminescence behavior based on Au-Cu alloy nanocrystals quenching for insulin detection.

    Science.gov (United States)

    Zhu, Wenjuan; Wang, Chao; Li, Xiaojian; Khan, Malik Saddam; Sun, Xu; Ma, Hongmin; Fan, Dawei; Wei, Qin

    2017-11-15

    Novel and sensitive sandwich-type electrochemiluminescence (ECL) immunosensor was fabricated for insulin detection. Au-ZnCd 14 S combined nitrogen doping mesoporous carbons (Au-ZnCd 14 S/NH 2 -NMCs) acted as sensing platform and Au-Cu alloy nanocrystals were employed as labels to quench the ECL of Au-ZnCd 14 S/NH 2 -NMCs. Zinc-doping promoted the ECL behavior of CdS nanocrystals, with the best ECL emission obtained when the molar ratio of Zn/Cd was 1:14. Simultaneously, the modification of gold nanoparticles (Au NPs) and combination with NH 2 -NMC further enhanced the ECL emission of ZnCd 14 S due to its excellent conductivity and large specific surface area, which is desirable for the immunosensor construction. Au-Cu alloy nanocrystals were employed in the ECL system of ZnCd 14 S/K 2 S 2 O 8 triggering ECL quenching effects. The ECL spectra of ZnCd 14 S, acting as the energy donor, exhibited well overlaps with the absorption band of Au-Cu alloy nanocrystals which acted as the energy acceptor, leading to an effective ECL resonance energy transfer (ECL-RET). On the basis of the ECL quenching effects, a sensitive ECL immunosensor for insulin detection was successfully constructed with a linear response range of insulin concentration from 0.1pg/mL to 30ng/mL and the limit of detection was calculated to be 0.03pg/mL (S/N = 3). Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Scanning Auger microscopy for high lateral and depth elemental sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, E., E-mail: eugenie.martinez@cea.fr [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Yadav, P. [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Bouttemy, M. [Institut Lavoisier de Versailles, 45 av. des Etats-Unis, 78035 Versailles Cedex (France); Renault, O.; Borowik, Ł.; Bertin, F. [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Etcheberry, A. [Institut Lavoisier de Versailles, 45 av. des Etats-Unis, 78035 Versailles Cedex (France); Chabli, A. [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France)

    2013-12-15

    Highlights: •SAM performances and limitations are illustrated on real practical cases such as the analysis of nanowires and nanodots. •High spatial elemental resolution is shown with the analysis of reference semiconducting Al{sub 0.7}Ga{sub 0.3}As/GaAs multilayers. •High in-depth elemental resolution is also illustrated. Auger depth profiling with low energy ion beams allows revealing ultra-thin layers (∼1 nm). •Analysis of cross-sectional samples is another effective approach to obtain in-depth elemental information. -- Abstract: Scanning Auger microscopy is currently gaining interest for investigating nanostructures or thin multilayers stacks developed for nanotechnologies. New generation Auger nanoprobes combine high lateral (∼10 nm), energy (0.1%) and depth (∼2 nm) resolutions thus offering the possibility to analyze the elemental composition as well as the chemical state, at the nanometre scale. We report here on the performances and limitations on practical examples from nanotechnology research. The spatial elemental sensitivity is illustrated with the analysis of Al{sub 0.7}Ga{sub 0.3}As/GaAs heterostructures, Si nanowires and SiC nanodots. Regarding the elemental in-depth composition, two effective approaches are presented: low energy depth profiling to reveal ultra-thin layers (∼1 nm) and analysis of cross-sectional samples.

  1. An ultrasensitive sandwich type electrochemiluminescence immunosensor for triiodothyronine detection using silver nanoparticle-decorated graphene oxide as a nanocarrier.

    Science.gov (United States)

    Chou, Hung-Tao; Fu, Chien-Yu; Lee, Chi-Young; Tai, Nyan-Hwa; Chang, Hwan-You

    2015-09-15

    An ultrasensitive electrochemiluminescence (ECL) immunosensor was constructed to detect 3,3',5-triiodothyronine (T3). The system employed T3-conjugated, silver nanoparticle-decorated carboxylic graphene oxide (Ag@fGO-T3) as a carrier and anti-T3 antibody-tris(2,2'-bipyridyl) ruthenium(II) (Ru(bpy)3(2+)) as a probe. The Ag@fGO-T3 and Ru(bpy)3(2+) complex could be mobilized rapidly to the anode in the reaction chamber through electrophoresis. The fGO is reduced electrochemically at the electrode, and the electrons could transfer from an anode to the Ru(bpy)3(2+). The complex is excited at the electrode and an ECL signal is produced upon reacting with tripropylamine (TPrA). Because of its large surface area and excellent conductivity, Ag@fGO could enhance ECL signal significantly in the system. Quantitative measurement of T3 could be achieved in the range from 0.1 pg/mL to 0.8 ng/mL with a detection limit of 0.05 pg/mL. In addition, the novel immunosensor showed good specificity in the presence of serum, indicating its high potential in clinical use. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Ultrasensitive electrochemiluminescent immunoassay for morphine using a gold electrode modified with CdS quantum dots, polyamidoamine, and gold nanoparticles

    International Nuclear Information System (INIS)

    Fei, Wenjuan; Chen, Feifei; Sun, Li; Li, Qianhua; Wu, Ying; Yang, Jianping

    2014-01-01

    We report on a novel electrochemiluminescent (ECL) immunoassay for the ultrasensitive determination of morphine by making use of a gold electrode which was modified with a nanocomposite film containing self-assembled polyamidoamine (PAMAM) CdS quantum dots and electrodeposited gold nanoparticles (Au-NPs). The highly uniform and well-dispersed quantum dots were capped with PAMAM dendrimers. Due to the synergistic effect of the modified quantum dots and the electrodeposited Au-NPs, the ECL response is dramatically enhanced. Under optimal experimental conditions, the immunoreaction between morphine and anti-morphine antibody resulted in a decrease of the ECL signal because of steric hindrance. The calibration plot is linear in the morphine concentration range from 0.2 to 180 ng•mL −1 , with a detection limit as low as 67 pg•mL −1 . The sensor was successfully applied to the determination of morphine in blood plasma. This kind of assay is expected to pave new avenues in label-free drug assays. (author)

  3. Metabolic Toxicity Screening Using Electrochemiluminescence Arrays Coupled with Enzyme-DNA Biocolloid Reactors and Liquid Chromatography–Mass Spectrometry

    Science.gov (United States)

    Hvastkovs, Eli G.; Schenkman, John B.; Rusling, James F.

    2012-01-01

    New chemicals or drugs must be guaranteed safe before they can be marketed. Despite widespread use of bioassay panels for toxicity prediction, products that are toxic to a subset of the population often are not identified until clinical trials. This article reviews new array methodologies based on enzyme/DNA films that form and identify DNA-reactive metabolites that are indicators of potentially genotoxic species. This molecularly based methodology is designed in a rapid screening array that utilizes electrochemiluminescence (ECL) to detect metabolite-DNA reactions, as well as biocolloid reactors that provide the DNA adducts and metabolites for liquid chromatography–mass spectrometry (LC-MS) analysis. ECL arrays provide rapid toxicity screening, and the biocolloid reactor LC-MS approach provides a valuable follow-up on structure, identification, and formation rates of DNA adducts for toxicity hits from the ECL array screening. Specific examples using this strategy are discussed. Integration of high-throughput versions of these toxicity-screening methods with existing drug toxicity bioassays should allow for better human toxicity prediction as well as more informed decision making regarding new chemical and drug candidates. PMID:22482786

  4. Laser-engraved carbon nanotube paper for instilling high sensitivity, high stretchability, and high linearity in strain sensors

    KAUST Repository

    Xin, Yangyang

    2017-06-29

    There is an increasing demand for strain sensors with high sensitivity and high stretchability for new applications such as robotics or wearable electronics. However, for the available technologies, the sensitivity of the sensors varies widely. These sensors are also highly nonlinear, making reliable measurement challenging. Here we introduce a new family of sensors composed of a laser-engraved carbon nanotube paper embedded in an elastomer. A roll-to-roll pressing of these sensors activates a pre-defined fragmentation process, which results in a well-controlled, fragmented microstructure. Such sensors are reproducible and durable and can attain ultrahigh sensitivity and high stretchability (with a gauge factor of over 4.2 × 10(4) at 150% strain). Moreover, they can attain high linearity from 0% to 15% and from 22% to 150% strain. They are good candidates for stretchable electronic applications that require high sensitivity and linearity at large strains.

  5. Determination of dioxopromethazine hydrochloride by capillary electrophoresis with electrochemiluminescence detection

    International Nuclear Information System (INIS)

    Li Yunhui; Wang Chunyan; Sun Jinying; Zhou Yongchang; You Tianyan; Wang Erkang; Fung Yingsing

    2005-01-01

    The paper presents a rapid method for the determination of dioxopromethazine hydrochloride (DPZ), an antihistamine drug, by the capillary electrophoresis with electrochemiluminescene detection (CE-ECL) using tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy) 3 2+ ) reagent. This CE-ECL detection method has high sensitivity, good selectivity and reproducibility for DPZ analysis. Under the optimized conditions: separation capillary, 38 cm length (25 μm i.d.); sample injection, 10 s at 8 kV; separation voltage, 12.5 kV; running buffer, 20 mmol L -1 sodium phosphate of pH 6.0; detection potential, 1.15 V; 50 mmol L -1 of phosphate buffer (pH 7.14) containing 5 mmol L -1 of Ru(bpy) 3 2+ in ECL detection cell, the detection limit of DPZ was 0.05 μmol L -1 (S/N = 3). The linear range extended from 5 to 100 μmol L -1 . The linear curve obtained was Y = 181.62 + 9.28X with a correlation coefficient of 0.9970. The relative standard deviations of the ECL intensity and the migration time for six continuous injections of 5 μmol L -1 DPZ were 3.7% and 0.92%, respectively. The CE-ECL method was applied to analyze DPZ in real samples including tablets, rat serum and human urine, and satisfactory results were obtained without interference from samples matrix. The CE-ECL technique was proved to be a potential method for the detection of DPZ in clinic analysis

  6. Accelerated Sensitivity Analysis in High-Dimensional Stochastic Reaction Networks.

    Science.gov (United States)

    Arampatzis, Georgios; Katsoulakis, Markos A; Pantazis, Yannis

    2015-01-01

    Existing sensitivity analysis approaches are not able to handle efficiently stochastic reaction networks with a large number of parameters and species, which are typical in the modeling and simulation of complex biochemical phenomena. In this paper, a two-step strategy for parametric sensitivity analysis for such systems is proposed, exploiting advantages and synergies between two recently proposed sensitivity analysis methodologies for stochastic dynamics. The first method performs sensitivity analysis of the stochastic dynamics by means of the Fisher Information Matrix on the underlying distribution of the trajectories; the second method is a reduced-variance, finite-difference, gradient-type sensitivity approach relying on stochastic coupling techniques for variance reduction. Here we demonstrate that these two methods can be combined and deployed together by means of a new sensitivity bound which incorporates the variance of the quantity of interest as well as the Fisher Information Matrix estimated from the first method. The first step of the proposed strategy labels sensitivities using the bound and screens out the insensitive parameters in a controlled manner. In the second step of the proposed strategy, a finite-difference method is applied only for the sensitivity estimation of the (potentially) sensitive parameters that have not been screened out in the first step. Results on an epidermal growth factor network with fifty parameters and on a protein homeostasis with eighty parameters demonstrate that the proposed strategy is able to quickly discover and discard the insensitive parameters and in the remaining potentially sensitive parameters it accurately estimates the sensitivities. The new sensitivity strategy can be several times faster than current state-of-the-art approaches that test all parameters, especially in "sloppy" systems. In particular, the computational acceleration is quantified by the ratio between the total number of parameters over the

  7. Accelerated Sensitivity Analysis in High-Dimensional Stochastic Reaction Networks.

    Directory of Open Access Journals (Sweden)

    Georgios Arampatzis

    Full Text Available Existing sensitivity analysis approaches are not able to handle efficiently stochastic reaction networks with a large number of parameters and species, which are typical in the modeling and simulation of complex biochemical phenomena. In this paper, a two-step strategy for parametric sensitivity analysis for such systems is proposed, exploiting advantages and synergies between two recently proposed sensitivity analysis methodologies for stochastic dynamics. The first method performs sensitivity analysis of the stochastic dynamics by means of the Fisher Information Matrix on the underlying distribution of the trajectories; the second method is a reduced-variance, finite-difference, gradient-type sensitivity approach relying on stochastic coupling techniques for variance reduction. Here we demonstrate that these two methods can be combined and deployed together by means of a new sensitivity bound which incorporates the variance of the quantity of interest as well as the Fisher Information Matrix estimated from the first method. The first step of the proposed strategy labels sensitivities using the bound and screens out the insensitive parameters in a controlled manner. In the second step of the proposed strategy, a finite-difference method is applied only for the sensitivity estimation of the (potentially sensitive parameters that have not been screened out in the first step. Results on an epidermal growth factor network with fifty parameters and on a protein homeostasis with eighty parameters demonstrate that the proposed strategy is able to quickly discover and discard the insensitive parameters and in the remaining potentially sensitive parameters it accurately estimates the sensitivities. The new sensitivity strategy can be several times faster than current state-of-the-art approaches that test all parameters, especially in "sloppy" systems. In particular, the computational acceleration is quantified by the ratio between the total number of

  8. Resonance energy transfer based electrochemiluminescence and fluorescence sensing of riboflavin using graphitic carbon nitride quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Huan [Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou, Gansu 730070 (China); The Phytochemistry Key Laboratory of Tibetan Plateau of Qinghai Province, College of Pharmacy, Qinghai Nationalities University, Xining, Qinghai 810007 (China); Ma, Qin; Wang, Yanfeng; Wang, Caihe; Qin, Dongdong; Shan, Duoliang; Chen, Jing [Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou, Gansu 730070 (China); Lu, Xiaoquan, E-mail: luxq@nwnu.edu.cn [Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou, Gansu 730070 (China)

    2017-06-22

    Graphitic carbon nitride quantum dots (g-CNQDs) are rarely used in the field of electrochemiluminescence. In this paper, g-CNQDs have a strong and stable electrochemiluminescence (ECL) signal generated in the presence of co-reactant K{sub 2}S{sub 2}O{sub 8}. The ECL signal of g-CNQDs was quenched by the mechanism of resonance energy transfer (RET) between donor g-CNQDs and receptor riboflavin (RF) that is proved by UV-vis absorption spectroscopy, electrochemiluminescence and fluorescence emission spectroscopy analysis technology. Therefore, we achieved detection of the riboflavin content in the drug tablets of vitamin B{sub 2} using ECL and FL. The determination results of ECL showed that the riboflavin content of the drug vitamin B{sub 2} (VB{sub 2}) tablets was consistent with the fluorescence (FL) analysis, with wider linear range of 0.02–11 μM and lower minimum detection limit of 0.63 nM (S/N = 3) than FL. Hence, the riboflavin content in human serum was further detected using ECL. The relative standard deviation is less than 6.5%, with an acceptable recovery of 95.33%–104.22%, which means that this sensor has potential applications in the actual sample analysis. As a new ECL luminary, g-CNQDs have opened a new field for the development and application of ECL sensor. - Highlights: • G-CNQDs proposed as a new luminophore for ECL. • ECL signal was strong and stable in the presence of co-reactant K{sub 2}S{sub 2}O{sub 8}. • Based on the resonance energy transfer between g-CNQDs and riboflavin. • ECL has wider linear range and lower detection limit than FL.

  9. Resonance energy transfer based electrochemiluminescence and fluorescence sensing of riboflavin using graphitic carbon nitride quantum dots

    International Nuclear Information System (INIS)

    Wang, Huan; Ma, Qin; Wang, Yanfeng; Wang, Caihe; Qin, Dongdong; Shan, Duoliang; Chen, Jing; Lu, Xiaoquan

    2017-01-01

    Graphitic carbon nitride quantum dots (g-CNQDs) are rarely used in the field of electrochemiluminescence. In this paper, g-CNQDs have a strong and stable electrochemiluminescence (ECL) signal generated in the presence of co-reactant K 2 S 2 O 8 . The ECL signal of g-CNQDs was quenched by the mechanism of resonance energy transfer (RET) between donor g-CNQDs and receptor riboflavin (RF) that is proved by UV-vis absorption spectroscopy, electrochemiluminescence and fluorescence emission spectroscopy analysis technology. Therefore, we achieved detection of the riboflavin content in the drug tablets of vitamin B 2 using ECL and FL. The determination results of ECL showed that the riboflavin content of the drug vitamin B 2 (VB 2 ) tablets was consistent with the fluorescence (FL) analysis, with wider linear range of 0.02–11 μM and lower minimum detection limit of 0.63 nM (S/N = 3) than FL. Hence, the riboflavin content in human serum was further detected using ECL. The relative standard deviation is less than 6.5%, with an acceptable recovery of 95.33%–104.22%, which means that this sensor has potential applications in the actual sample analysis. As a new ECL luminary, g-CNQDs have opened a new field for the development and application of ECL sensor. - Highlights: • G-CNQDs proposed as a new luminophore for ECL. • ECL signal was strong and stable in the presence of co-reactant K 2 S 2 O 8 . • Based on the resonance energy transfer between g-CNQDs and riboflavin. • ECL has wider linear range and lower detection limit than FL.

  10. Comparison of unusual carbon-based working electrodes for electrochemiluminescence sensors.

    Science.gov (United States)

    Noman, Muhammad; Sanginario, Alessandro; Jagadale, Pravin; Demarchi, Danilo; Tagliaferro, Alberto

    2017-06-01

    In this work, unconventional carbon-based materials were investigated for use in electrochemiluminescence (ECL) working electrodes. Precursors such as bamboo, pistachio shells, kevlar ® fibers and camphor were differently treated and used as working electrodes in ECL experiments. After a proper process they were assembled as electrodes and tested in an electrochemical cell. Comparison among them and with a commercial glassy carbon electrode (GCE) shows a very good response for all of them thus demonstrating their potential use as disposable low-cost electrodes for early detection electrochemical analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Highly sensitive and multiplexed platforms for allergy diagnostics

    Science.gov (United States)

    Monroe, Margo R.

    Allergy is a disorder of the immune system caused by an immune response to otherwise harmless environmental allergens. Currently 20% of the US population is allergic and 90% of pediatric patients and 60% of adult patients with asthma have allergies. These percentages have increased by 18.5% in the past decade, with predicted similar trends for the future. Here we design sensitive, multiplexed platforms to detect allergen-specific IgE using the Interferometric Reflectance Imaging Sensor (IRIS) for various clinical settings. A microarray platform for allergy diagnosis allows for testing of specific IgE sensitivity to a multitude of allergens, while requiring only small volumes of patient blood sample. However, conventional fluorescent microarray technology is limited by i) the variation of probe immobilization, which hinders the ability to make quantitative, assertive, and statistically relevant conclusions necessary in immunodiagnostics and ii) the use of fluorophore labels, which is not suitable for some clinical applications due to the tendency of fluorophores to stick to blood particulates and require daily calibration methods. This calibrated fluorescence enhancement (CaFE) method integrates the low magnification modality of IRIS with enhanced fluorescence sensing in order to directly correlate immobilized probe (major allergens) density to allergen-specific IgE in patient serum. However, this platform only operates in processed serum samples, which is not ideal for point of care testing. Thus, a high magnification modality of IRIS was adapted as an alternative allergy diagnostic platform to automatically discriminate and size single nanoparticles bound to specific IgE in unprocessed, characterized human blood and serum samples. These features make IRIS an ideal candidate for clinical and diagnostic applications, such a POC testing. The high magnification (nanoparticle counting) modality in conjunction with low magnification of IRIS in a combined instrument

  12. An Ultrasensitive Electrochemiluminescence Immunoassay for Carbohydrate Antigen 19-9 in Serum Based on Antibody Labeled Fe3O4 Nanoparticles as Capture Probes and Graphene/CdTe Quantum Dot Bionanoconjugates as Signal Amplifiers

    Science.gov (United States)

    Gan, Ning; Zhou, Jing; Xiong, Ping; Li, Tianhua; Jiang, Shan; Cao, Yuting; Jiang, Qianli

    2013-01-01

    The CdTe quantum dots (QDs), graphene nanocomposite (CdTe-G) and dextran–Fe3O4 magnetic nanoparticles have been synthesized for developing an ultrasensitive electrochemiluminescence (ECL) immunoassay for Carcinoembryonic antigen 19-9 (CA 19-9) in serums. Firstly, the capture probes (CA 19-9 Ab1/Fe3O4) for enriching CA 19-9 were synthesized by immobilizing the CA 19-9’s first antibody (CA 19-9 Ab1) on magnetic nanoparticles (dextran-Fe3O4). Secondly, the signal probes (CA 19-9 Ab2/CdTe-G), which can emit an ECL signal, were formed by attaching the secondary CA 19-9 antibody (CA 19-9 Ab2) to the surface of the CdTe-G. Thirdly, the above two probes were used for conjugating with a serial of CA 19-9 concentrations. Graphene can immobilize dozens of CdTe QDs on their surface, which can emit stronger ECL intensity than CdTe QDs. Based on the amplified signal, ultrasensitive antigen detection can be realized. Under the optimal conditions, the ECL signal depended linearly on the logarithm of CA 19-9 concentration from 0.005 to 100 pg/mL, and the detection limit was 0.002 pg/mL. Finally, five samples of human serum were tested, and the results were compared with a time-resolved fluorescence assay (TRFA). The novel immunoassay provides a stable, specific and highly sensitive immunoassay protocol for tumor marker detection at very low levels, which can be applied in early diagnosis of tumor. PMID:23685872

  13. Adjoint sensitivity analysis of high frequency structures with Matlab

    CERN Document Server

    Bakr, Mohamed; Demir, Veysel

    2017-01-01

    This book covers the theory of adjoint sensitivity analysis and uses the popular FDTD (finite-difference time-domain) method to show how wideband sensitivities can be efficiently estimated for different types of materials and structures. It includes a variety of MATLAB® examples to help readers absorb the content more easily.

  14. Polypyrrole–gold nanoparticle composites for highly sensitive DNA detection

    International Nuclear Information System (INIS)

    Spain, Elaine; Keyes, Tia E.; Forster, Robert J.

    2013-01-01

    DNA capture surfaces represent a powerful approach to developing highly sensitive sensors for identifying the cause of infection. Electrochemically deposited polypyrrole, PPy, films have been functionalized with electrodeposited gold nanoparticles to give a nanocomposite material, PPy–AuNP. Thiolated capture strand DNA, that is complementary to the sequence from the pathogen Staphylococcus aureus that causes mammary gland inflammation, was then immobilized onto the gold nanoparticles and any of the underlying gold electrode that is exposed. A probe strand, labelled with horse radish peroxidase, HRP, was then hybridized to the target. The concentration of the target was determined by measuring the current generated by reducing benzoquinone produced by the HRP label. Semi-log plots of the pathogen DNA concentration vs. faradaic current are linear from 150 pM to 1 μM and pM concentrations can be detected without the need for molecular, e.g., PCR or NASBA, amplification. The nanocomposite also exhibits excellent selectivity and single base mismatches in a 30 mer sequence can be detected

  15. Improvement of sensitivity in high-resolution Rutherford backscattering spectroscopy

    International Nuclear Information System (INIS)

    Hashimoto, H.; Nakajima, K.; Suzuki, M.; Kimura, K.; Sasakawa, K.

    2011-01-01

    The sensitivity (limit of detection) of high-resolution Rutherford backscattering spectroscopy (HRBS) is mainly determined by the background noise of the spectrometer. There are two major origins of the background noise in HRBS, one is the stray ions scattered from the inner wall of the vacuum chamber of the spectrometer and the other is the dark noise of the microchannel plate (MCP) detector which is commonly used as a focal plane detector of the spectrometer in HRBS. In order to reject the stray ions, several barriers are installed inside the spectrometer and a thin Mylar foil is mounted in front of the detector. The dark noise of the MCP detector is rejected by the coincidence measurement with the secondary electrons emitted from the Mylar foil upon the ion passage. After these improvements, the background noise is reduced by a factor of 200 at a maximum. The detection limit can be improved down to 10 ppm for As in Si at a measurement time of 1 h under ideal conditions.

  16. Highly sensitive MoS2 photodetectors with graphene contacts

    Science.gov (United States)

    Han, Peize; St. Marie, Luke; Wang, Qing X.; Quirk, Nicholas; El Fatimy, Abdel; Ishigami, Masahiro; Barbara, Paola

    2018-05-01

    Two-dimensional materials such as graphene and transition metal dichalcogenides (TMDs) are ideal candidates to create ultra-thin electronics suitable for flexible substrates. Although optoelectronic devices based on TMDs have demonstrated remarkable performance, scalability is still a significant issue. Most devices are created using techniques that are not suitable for mass production, such as mechanical exfoliation of monolayer flakes and patterning by electron-beam lithography. Here we show that large-area MoS2 grown by chemical vapor deposition and patterned by photolithography yields highly sensitive photodetectors, with record shot-noise-limited detectivities of 8.7 × 1014 Jones in ambient condition and even higher when sealed with a protective layer. These detectivity values are higher than the highest values reported for photodetectors based on exfoliated MoS2. We study MoS2 devices with gold electrodes and graphene electrodes. The devices with graphene electrodes have a tunable band alignment and are especially attractive for scalable ultra-thin flexible optoelectronics.

  17. Ultra-high sensitivity imaging of cancer using SERRS nanoparticles

    Science.gov (United States)

    Kircher, Moritz F.

    2016-05-01

    "Surface-enhanced Raman spectroscopy" (SERS) nanoparticles have gained much attention in recent years for in silico, in vitro and in vivo sensing applications. Our group has developed novel generations of biocompatible "surfaceenhanced resonance Raman spectroscopy" (SERRS) nanoparticles as novel molecular imaging agents. Via rigorous optimization of the different variables contributing to the Raman enhancement, we were able to design SERRS nanoparticles with so far unprecedented sensitivity of detection under in vivo imaging conditions (femto-attomolar range). This has resulted in our ability to visualize, with a single nanoparticle, many different cancer types (after intravenous injection) in mouse models. The cancer types we have tested so far include brain, breast, esophagus, stomach, pancreas, colon, sarcoma, and prostate cancer. All mouse models used are state-of-the-art and closely mimic the tumor biology in their human counterparts. In these animals, we were able to visualize not only the bulk tumors, but importantly also microscopic extensions and locoregional satellite metastases, thus delineating for the first time the true extent of tumor spread. Moreover, the particles enable the detection of premalignant lesions. Given their inert composition they are expected to have a high chance for clinical translation, where we envision them to have an impact in various scenarios ranging from early detection, image-guidance in open or minimally invasive surgical procedures, to noninvasive imaging in conjunction with spatially offset (SESORS) Raman detection devices.

  18. Characterization of three high efficiency and blue sensitive silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Otte, Adam Nepomuk, E-mail: otte@gatech.edu; Garcia, Distefano; Nguyen, Thanh; Purushotham, Dhruv

    2017-02-21

    We report about the optical and electrical characterization of three high efficiency and blue sensitive Silicon photomultipliers from FBK, Hamamatsu, and SensL. Key features of the tested devices when operated at 90% breakdown probability are peak photon detection efficiencies between 40% and 55%, temperature dependencies of gain and PDE that are less than 1%/°C, dark rates of ∼50 kHz/mm{sup 2} at room temperature, afterpulsing of about 2%, and direct optical crosstalk between 6% and 20%. The characteristics of all three devices impressively demonstrate how the Silicon-photomultiplier technology has improved over the past ten years. It is further demonstrated how the voltage and temperature characteristics of a number of quantities can be parameterized on the basis of physical models. The models provide a deeper understanding of the device characteristics over a wide bias and temperature range. They also serve as examples how producers could provide the characteristics of their SiPMs to users. A standardized parameterization of SiPMs would enable users to find the optimal SiPM for their application and the operating point of SiPMs without having to perform measurements thus significantly reducing design and development cycles.

  19. Introducing wet aerosols into the static high sensitivity ICP (SHIP)

    Energy Technology Data Exchange (ETDEWEB)

    Scheffer, Andy; Engelhard, Carsten; Sperling, Michael; Buscher, Wolfgang [University of Muenster, Institute of Inorganic and Analytical Chemistry, Muenster (Germany)

    2007-08-15

    A demountable design of the static high sensitivity ICP (SHIP) for optical emission spectrometry is presented, and its use as an excitation source with the introduction of wet aerosols was investigated. Aerosols were produced by standard pneumatic sample introduction systems, namely a cross flow nebulizer, Meinhard nebulizer and PFA low flow nebulizer, which have been applied in conjunction with a double pass and a cyclonic spray chamber. The analytical capabilities of these sample introduction systems in combination with the SHIP system were evaluated with respect to the achieved sensitivity. It was found that a nebulizer tailored for low argon flow rates (0.3-0.5 L min{sup -1}) is best suited for the low flow plasma (SHIP). An optimization of all gas flow rates of the SHIP system with the PFA low flow nebulizer was carried out in a two-dimensional way with the signal to background ratio (SBR) and the robustness as optimization target parameters. Optimum conditions for a torch model with 1-mm injector tube were 0.25 and 0.36 L min{sup -1} for the plasma gas and the nebulizer gas, respectively. A torch model with a 2-mm injector tube was optimized to 0.4 L min{sup -1} for the plasma gas and 0.44 L min{sup -1} for the nebulizer gas. In both cases the SHIP system saves approximately 95% of the argon consumed by conventional inductively coupled plasma systems. The limits of detection were found to be in the low microgram per litre range and below for many elements, which was quite comparable to those of the conventional setup. Furthermore, the short-term stability and the wash out behaviour of the SHIP were investigated. Direct comparison with the conventional setup indicated that no remarkable memory effects were caused by the closed design of the torch. The analysis of a NIST SRM 1643e (Trace Elements in Water) with the SHIP yielded recoveries of 97-103% for 13 elements, measured simultaneously. (orig.)

  20. The sandwich-type electrochemiluminescence immunosensor for {alpha}-fetoprotein based on enrichment by Fe{sub 3}O{sub 4}-Au magnetic nano probes and signal amplification by CdS-Au composite nanoparticles labeled anti-AFP

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Hankun [State Key Laboratory Base of Novel Functional Materials and Preparation Science, Faculty of Material Science and Chemical Engineering of Ningbo University, Ningbo 315211 (China); Gan Ning, E-mail: ganning@nbu.edu.cn [State Key Laboratory Base of Novel Functional Materials and Preparation Science, Faculty of Material Science and Chemical Engineering of Ningbo University, Ningbo 315211 (China); Li Tianhua; Cao Yuting; Zeng Saolin [State Key Laboratory Base of Novel Functional Materials and Preparation Science, Faculty of Material Science and Chemical Engineering of Ningbo University, Ningbo 315211 (China); Zheng Lei, E-mail: nfyyzl@163.com [Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China); Guo Zhiyong [State Key Laboratory Base of Novel Functional Materials and Preparation Science, Faculty of Material Science and Chemical Engineering of Ningbo University, Ningbo 315211 (China)

    2012-10-09

    Highlights: Black-Right-Pointing-Pointer Sandwich immunoreaction, testing a large number of samples simultaneously. Black-Right-Pointing-Pointer The magnetic separation and enrichment by Fe{sub 3}O{sub 4}-Au magnetic nano probes. Black-Right-Pointing-Pointer The amplification of detection signal by CdS-Au composite nanoparticles labeled anti-AFP. Black-Right-Pointing-Pointer Almost no background signal, which greatly improve the sensitivity of detection. - Abstract: A novel and sensitive sandwich-type electrochemiluminescence (ECL) immunosensor was fabricated on a glassy carbon electrode (GCE) for ultra trace levels of {alpha}-fetoprotein (AFP) based on sandwich immunoreaction strategy by enrichment using magnetic capture probes and quantum dots coated with Au shell (CdS-Au) as the signal tag. The capture probe was prepared by immobilizing the primary antibody of AFP (Ab1) on the core/shell Fe{sub 3}O{sub 4}-Au nanoparticles, which was first employed to capture AFP antigens to form Fe{sub 3}O{sub 4}-Au/Ab1/AFP complex from the serum after incubation. The product can be separated from the background solution through the magnetic separation. Then the CdS-Au labeled secondary antibody (Ab2) as signal tag (CdS-Au/Ab2) was conjugated successfully with Fe{sub 3}O{sub 4}-Au/Ab1/AFP complex to form a sandwich-type immunocomplex (Fe{sub 3}O{sub 4}-Au/Ab1/AFP/Ab2/CdS-Au), which can be further separated by an external magnetic field and produce ECL signals at a fixed voltage. The signal was proportional to a certain concentration range of AFP for quantification. Thus, an easy-to-use immunosensor with magnetic probes and a quantum dots signal tag was obtained. The immunosensor performed at a level of high sensitivity and a broad concentration range for AFP between 0.0005 and 5.0 ng mL{sup -1} with a detection limit of 0.2 pg mL{sup -1}. The use of magnetic probes was combined with pre-concentration and separation for trace levels of tumor markers in the serum. Due to the

  1. High-sensitivity Cardiac Troponin Elevation after Electroconvulsive Therapy (ECT)

    Science.gov (United States)

    Duma, Andreas; Pal, Swatilika; Johnston, Joshua; Helwani, Mohammad A.; Bhat, Adithya; Gill, Bali; Rosenkvist, Jessica; Cartmill, Christopher; Brown, Frank; Miller, J. Philip; Scott, Mitchell G; Sanchez-Conde, Francisco; Jarvis, Michael; Farber, Nuri B.; Zorumski, Charles F.; Conway, Charles; Nagele, Peter

    2017-01-01

    Background While electroconvulsive therapy (ECT) is widely regarded as a life-saving and safe procedure, evidence regarding its effects on myocardial cell injury are sparse. The objective of this investigation was to determine incidence and magnitude of new cardiac troponin elevation after ECT using a novel high-sensitivity cardiac troponin I (hscTnI) assay. Methods This was a prospective cohort study in adult patients undergoing ECT in a single academic center (up to three ECT treatments per patient). The primary outcome was new hscTnI elevation after ECT, defined as an increase of hscTnI >100% after ECT compared to baseline with at least one value above the limit of quantification (10 ng/L). 12-lead ECG and hscTnI values were obtained prior to and 15–30 minutes after ECT; in a subset of patients an additional 2-hour hscTnI value was obtained. Results The final study population was 100 patients and a total of 245 ECT treatment sessions. Eight patients (8/100, 8%) experienced new hscTnI elevation after ECT with a cumulative incidence of 3.7% (9/245 treatments; one patient had two hscTnI elevations), two of whom had a non-ST-elevation myocardial infarction (incidence 2/245, 0.8%). Median hscTnI concentrations did not increase significantly after ECT. Tachycardia and/or elevated systolic blood pressure developed after approximately two thirds of ECT treatments. Conclusions ECT appears safe from a cardiac standpoint in a large majority of patients. A small subset of patients with pre-existing cardiovascular risk factors, however, may develop new cardiac troponin elevation after ECT, the clinical relevance of which is unclear in the absence of signs of myocardial ischemia. PMID:28166110

  2. High-intensity xenon plasma discharge lamp for bulk-sensitive high-resolution photoemission spectroscopy.

    Science.gov (United States)

    Souma, S; Sato, T; Takahashi, T; Baltzer, P

    2007-12-01

    We have developed a highly brilliant xenon (Xe) discharge lamp operated by microwave-induced electron cyclotron resonance (ECR) for ultrahigh-resolution bulk-sensitive photoemission spectroscopy (PES). We observed at least eight strong radiation lines from neutral or singly ionized Xe atoms in the energy region of 8.4-10.7 eV. The photon flux of the strongest Xe I resonance line at 8.437 eV is comparable to that of the He Ialpha line (21.218 eV) from the He-ECR discharge lamp. Stable operation for more than 300 h is achieved by efficient air-cooling of a ceramic tube in the resonance cavity. The high bulk sensitivity and high-energy resolution of PES using the Xe lines are demonstrated for some typical materials.

  3. Development of high sensitivity and high speed large size blank inspection system LBIS

    Science.gov (United States)

    Ohara, Shinobu; Yoshida, Akinori; Hirai, Mitsuo; Kato, Takenori; Moriizumi, Koichi; Kusunose, Haruhiko

    2017-07-01

    The production of high-resolution flat panel displays (FPDs) for mobile phones today requires the use of high-quality large-size photomasks (LSPMs). Organic light emitting diode (OLED) displays use several transistors on each pixel for precise current control and, as such, the mask patterns for OLED displays are denser and finer than the patterns for the previous generation displays throughout the entire mask surface. It is therefore strongly demanded that mask patterns be produced with high fidelity and free of defect. To enable the production of a high quality LSPM in a short lead time, the manufacturers need a high-sensitivity high-speed mask blank inspection system that meets the requirement of advanced LSPMs. Lasertec has developed a large-size blank inspection system called LBIS, which achieves high sensitivity based on a laser-scattering technique. LBIS employs a high power laser as its inspection light source. LBIS's delivery optics, including a scanner and F-Theta scan lens, focus the light from the source linearly on the surface of the blank. Its specially-designed optics collect the light scattered by particles and defects generated during the manufacturing process, such as scratches, on the surface and guide it to photo multiplier tubes (PMTs) with high efficiency. Multiple PMTs are used on LBIS for the stable detection of scattered light, which may be distributed at various angles due to irregular shapes of defects. LBIS captures 0.3mμ PSL at a detection rate of over 99.5% with uniform sensitivity. Its inspection time is 20 minutes for a G8 blank and 35 minutes for G10. The differential interference contrast (DIC) microscope on the inspection head of LBIS captures high-contrast review images after inspection. The images are classified automatically.

  4. Model dependence of isospin sensitive observables at high densities

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Wen-Mei [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); School of Science, Huzhou Teachers College, Huzhou 313000 (China); Yong, Gao-Chan, E-mail: yonggaochan@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); State Key Laboratory of Theoretical Physics, Institute of Theoretical Physics, Chinese Academy of Sciences, Beijing 100190 (China); Wang, Yongjia [School of Science, Huzhou Teachers College, Huzhou 313000 (China); School of Nuclear Science and Technology, Lanzhou University, Lanzhou 730000 (China); Li, Qingfeng [School of Science, Huzhou Teachers College, Huzhou 313000 (China); Zhang, Hongfei [School of Nuclear Science and Technology, Lanzhou University, Lanzhou 730000 (China); State Key Laboratory of Theoretical Physics, Institute of Theoretical Physics, Chinese Academy of Sciences, Beijing 100190 (China); Zuo, Wei [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); State Key Laboratory of Theoretical Physics, Institute of Theoretical Physics, Chinese Academy of Sciences, Beijing 100190 (China)

    2013-10-07

    Within two different frameworks of isospin-dependent transport model, i.e., Boltzmann–Uehling–Uhlenbeck (IBUU04) and Ultrarelativistic Quantum Molecular Dynamics (UrQMD) transport models, sensitive probes of nuclear symmetry energy are simulated and compared. It is shown that neutron to proton ratio of free nucleons, π{sup −}/π{sup +} ratio as well as isospin-sensitive transverse and elliptic flows given by the two transport models with their “best settings”, all have obvious differences. Discrepancy of numerical value of isospin-sensitive n/p ratio of free nucleon from the two models mainly originates from different symmetry potentials used and discrepancies of numerical value of charged π{sup −}/π{sup +} ratio and isospin-sensitive flows mainly originate from different isospin-dependent nucleon–nucleon cross sections. These demonstrations call for more detailed studies on the model inputs (i.e., the density- and momentum-dependent symmetry potential and the isospin-dependent nucleon–nucleon cross section in medium) of isospin-dependent transport model used. The studies of model dependence of isospin sensitive observables can help nuclear physicists to pin down the density dependence of nuclear symmetry energy through comparison between experiments and theoretical simulations scientifically.

  5. High contrast sensitivity for visually guided flight control in bumblebees.

    Science.gov (United States)

    Chakravarthi, Aravin; Kelber, Almut; Baird, Emily; Dacke, Marie

    2017-12-01

    Many insects rely on vision to find food, to return to their nest and to carefully control their flight between these two locations. The amount of information available to support these tasks is, in part, dictated by the spatial resolution and contrast sensitivity of their visual systems. Here, we investigate the absolute limits of these visual properties for visually guided position and speed control in Bombus terrestris. Our results indicate that the limit of spatial vision in the translational motion detection system of B. terrestris lies at 0.21 cycles deg -1 with a peak contrast sensitivity of at least 33. In the perspective of earlier findings, these results indicate that bumblebees have higher contrast sensitivity in the motion detection system underlying position control than in their object discrimination system. This suggests that bumblebees, and most likely also other insects, have different visual thresholds depending on the behavioral context.

  6. Multiplex electrochemiluminescence DNA sensor for determination of hepatitis B virus and hepatitis C virus based on multicolor quantum dots and Au nanoparticles

    International Nuclear Information System (INIS)

    Liu, Linlin; Wang, Xinyan; Ma, Qiang; Lin, Zihan; Chen, Shufan; Li, Yang; Lu, Lehui; Qu, Hongping; Su, Xingguang

    2016-01-01

    In this work, a novel multiplex electrochemiluminescence (ECL) DNA sensor has been developed for determination of hepatitis B virus (HBV) and hepatitis C virus (HCV) based on multicolor CdTe quantum dots (CdTe QDs) and Au nanoparticles (Au NPs). The electrochemically synthesized graphene nanosheets (GNs) were selected as conducting bridge to anchor CdTe QDs_5_5_1-capture DNA_H_B_V and CdTe QDs_6_0_7-capture DNA_H_C_V on the glassy carbon electrode (GCE). Then, different concentrations of target DNA_H_B_V and target DNA_H_C_V were introduced to hybrid with complementary CdTe QDs-capture DNA. Au NPs-probe DNA_H_B_V and Au NPs-probe DNA_H_C_V were modified to the above composite film via hybrid with the unreacted complementary CdTe QDs-capture DNA. Au NPs could quench the electrochemiluminescence (ECL) intensity of CdTe QDs due to the inner filter effect. Therefore, the determination of target DNA_H_B_V and target DNA_H_C_V could be achieved by monitoring the ECL DNA sensor based on Au NPs-probe DNA/target DNA/CdTe QDs-capture DNA/GNs/GCE composite film. Under the optimum conditions, the ECL intensity of CdTe QDs_5_5_1 and CdTe QDs_6_0_7 and the concentration of target DNA_H_B_V and target DNA_H_C_V have good linear relationship in the range of 0.0005–0.5 nmol L"−"1 and 0.001–1.0 nmol L"−"1 respectively, and the limit of detection were 0.082 pmol L"−"1 and 0.34 pmol L"−"1 respectively (S/N = 3). The DNA sensor showed good sensitivity, selectivity, reproducibility and acceptable stability. The proposed DNA sensor has been employed for the determination of target DNA_H_B_V and target DNA_H_C_V in human serum samples with satisfactory results. - Highlights: • A novel electrochemiluminescence DNA sensor has been developed for the determination of target DNA_H_B_V and target DNA_H_C_V. • The DNA sensor shows good sensitivity, reproducibility and stability. • The ECL provided a convenient, low-cost, sensitive, and specific method for target DNA

  7. Metal ion-organic compound for high sensitive ESR dosimetry

    International Nuclear Information System (INIS)

    Hassan, G.M.; Ikeya, Motoji

    2000-01-01

    A systematic study to find a tissue equivalent and high sensitive dosimeter material has been made to stimulate the field of ESR dosimetry. Lithium acetate dihydrate (Li-Ac·2H 2 O:CH 3 COOLi·2H 2 O) and lithium phosphate (Li-phosphate:Li 3 PO 4 ) were irradiated by γ-rays to study radicals with (ESR) in addition to magnesium lactate (Mg-lactate (CH 3 CH(OH)COO) 2 Mg) doped with nominal pure lithium lactate (Mg(Li)-lactate) and lithium lactate (CH 3 CH(OH)COOLi) doped with Mg-lactate (Li(Mg)-lactate). A triplet spectrum with intensity ratio of 1:2:1 in Li-Ac·2H 2 O was ascribed to acetate radical which has g=2.0031±0.0004 and hyperfine splitting of A/gβ=2.12±0.1 mT. The Li-phosphate spectrum shows splitting due to anisotropic g-factors of g par =2.0190±0.0005 and g perp =1.9974±0.0004. Quartet spectra with the intensity ratio of 1:3:3:1 in Mg(Li)-lactate and Li(Mg)-lactate were ascribed to lactate radicals with g-factors of 2.0032 ± 0.0004 and 2.0029 ± 0.0004 and the intensity ratio of 1:3:3:1 and A/gβ=1.92±0.06 and 1.82 ± 0.06 mT, respectively. The response to γ-ray dose and the thermal stability as well as the effect of UV-illumination have been studied. The obtained number of free radicals per 100 eV (G-values) were 0.4 ± 0.13, 1.02 ± 0.31, 1.35 ± 0.35 and 0.78 ± 0 for Li-Ac.2H 2 O, Li-phosphate, Mg(Li)-lactate, and Li(Mg)-lactate, respectively. The lifetimes were estimated from Arrhenius plots to be approximately 2.0 ± 0.6, 50.7 ± 20 and 10 ± 3.5 years for Li-phosphate, Mg(Li)-lactate and Li(Mg)-lactate, respectively. The lifetime for Li-Ac·2H 2 O cannot be estimated because of the decomposition by heating

  8. Development of High Temperature/High Sensitivity Novel Chemical Resistive Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Chunrui [Univ. of Texas, San Antonio, TX (United States); Enriquez, Erik [Univ. of Texas, San Antonio, TX (United States); Wang, Haibing [Univ. of Texas, San Antonio, TX (United States); Xu, Xing [Univ. of Texas, San Antonio, TX (United States); Bao, Shangyong [Univ. of Texas, San Antonio, TX (United States); Collins, Gregory [Univ. of Texas, San Antonio, TX (United States)

    2013-08-13

    The research has been focused to design, fabricate, and develop high temperature/high sensitivity novel multifunctional chemical sensors for the selective detection of fossil energy gases used in power and fuel systems. By systematically studying the physical properties of the LnBaCo2O5+d (LBCO) [Ln=Pr or La] thin-films, a new concept chemical sensor based high temperature chemical resistant change has been developed for the application for the next generation highly efficient and near zero emission power generation technologies. We also discovered that the superfast chemical dynamic behavior and an ultrafast surface exchange kinetics in the highly epitaxial LBCO thin films. Furthermore, our research indicates that hydrogen can superfast diffuse in the ordered oxygen vacancy structures in the highly epitaxial LBCO thin films, which suggest that the LBCO thin film not only can be an excellent candidate for the fabrication of high temperature ultra sensitive chemical sensors and control systems for power and fuel monitoring systems, but also can be an excellent candidate for the low temperature solid oxide fuel cell anode and cathode materials.

  9. High-speed high-sensitivity infrared spectroscopy using mid-infrared swept lasers (Conference Presentation)

    Science.gov (United States)

    Childs, David T. D.; Groom, Kristian M.; Hogg, Richard A.; Revin, Dmitry G.; Cockburn, John W.; Rehman, Ihtesham U.; Matcher, Stephen J.

    2016-03-01

    Infrared spectroscopy is a highly attractive read-out technology for compositional analysis of biomedical specimens because of its unique combination of high molecular sensitivity without the need for exogenous labels. Traditional techniques such as FTIR and Raman have suffered from comparatively low speed and sensitivity however recent innovations are challenging this situation. Direct mid-IR spectroscopy is being speeded up by innovations such as MEMS-based FTIR instruments with very high mirror speeds and supercontinuum sources producing very high sample irradiation levels. Here we explore another possible method - external cavity quantum cascade lasers (EC-QCL's) with high cavity tuning speeds (mid-IR swept lasers). Swept lasers have been heavily developed in the near-infrared where they are used for non-destructive low-coherence imaging (OCT). We adapt these concepts in two ways. Firstly by combining mid-IR quantum cascade gain chips with external cavity designs adapted from OCT we achieve spectral acquisition rates approaching 1 kHz and demonstrate potential to reach 100 kHz. Secondly we show that mid-IR swept lasers share a fundamental sensitivity advantage with near-IR OCT swept lasers. This makes them potentially able to achieve the same spectral SNR as an FTIR instrument in a time x N shorter (N being the number of spectral points) under otherwise matched conditions. This effect is demonstrated using measurements of a PDMS sample. The combination of potentially very high spectral acquisition rates, fundamental SNR advantage and the use of low-cost detector systems could make mid-IR swept lasers a powerful technology for high-throughput biomedical spectroscopy.

  10. Imprinting of molecular recognition sites combined with π-donor-acceptor interactions using bis-aniline-crosslinked Au-CdSe/ZnS nanoparticles array on electrodes: Development of electrochemiluminescence sensor for the ultrasensitive and selective detection of 2-methyl-4-chlorophenoxyacetic acid.

    Science.gov (United States)

    Yang, Yukun; Fang, Guozhen; Wang, Xiaomin; Liu, Guiyang; Wang, Shuo

    2016-03-15

    A novel strategy is reported for the fabrication of bis-aniline-crosslinked Au nanoparticles (NPs)-CdSe/ZnS quantum dots (QDs) array composite by facil one-step co-electropolymerization of thioaniline-functionalized AuNPs and thioaniline-functionalized CdSe/ZnS QDs onto thioaniline-functionalized Au elctrodes (AuE). Stable and enhanced cathodic electrochemiluminescence (ECL) of CdSe/ZnS QDs is observed on the modified electrode in neutral solution, suggesting promising applications in ECL sensing. An advanced ECL sensor is explored for detection of 2-methyl-4-chlorophenoxyacetic acid (MCPA) which quenches the ECL signal through electron-transfer pathway. The sensitive determination of MCPA with limit of detection (LOD) of 2.2 nmolL(-1) (S/N=3) is achieved by π-donor-acceptor interactions between MCPA and the bis-aniline bridging units. Impressively, the imprinting of molecular recognition sites into the bis-aniline-crosslinked AuNPs-CdSe/ZnS QDs array yields a functionalized electrode with an extremely sensitive response to MCPA in a linear range of 10 pmolL(-1)-50 μmolL(-1) with a LOD of 4.3 pmolL(-1 ()S/N=3). The proposed ECL sensor with high sensitivity, good selectivity, reproducibility and stability has been successfully applied for the determination of MCPA in real samples with satisfactory recoveries. In this study, ECL sensor combined the merits of QDs-ECL and molecularly imprinting technology is reported for the first time. The developed ECL sensor holds great promise for the fabrication of QDs-based ECL sensors with improved sensitivity and furthermore opens the door to wide applications of QDs-based ECL in food safety and environmental monitoring. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. The Pajarito Monitor: a high-sensitivity monitoring system for highly enriched uranium

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.; Garcia, C.; Martinez, J.

    1984-01-01

    The Pajarito Monitor for Special Nuclear Material is a high-sensitivity gamma-ray monitoring system for detecting small quantities of highly enriched uranium transported by pedestrians or motor vehicles. The monitor consists of two components: a walk-through personnel monitor and a vehicle monitor. The personnel monitor has a plastic-scintillator detector portal, a microwave occupancy monitor, and a microprocessor control unit that measures the radiation intensity during background and monitoring periods to detect transient diversion signals. The vehicle monitor examines stationary motor vehicles while the vehicle's occupants pass through the personnel portal to exchange their badges. The vehicle monitor has four groups of large plastic scintillators that scan the vehicle from above and below. Its microprocessor control unit measures separate radiation intensities in each detector group. Vehicle occupancy is sensed by a highway traffic detection system. Each monitor's controller is responsible for detecting diversion as well as serving as a calibration and trouble-shooting aid. Diversion signals are detected by a sequential probability ratio hypothesis test that minimizes the monitoring time in the vehicle monitor and adapts itself well to variations in individual passage speed in the personnel monitor. Designed to be highly sensitive to diverted enriched uranium, the monitoring system also exhibits exceptional sensitivity for plutonium

  12. Desensitization protocol in highly HLA-sensitized and ABO-incompatible high titer kidney transplantation.

    Science.gov (United States)

    Uchida, J; Machida, Y; Iwai, T; Naganuma, T; Kitamoto, K; Iguchi, T; Maeda, S; Kamada, Y; Kuwabara, N; Kim, T; Nakatani, T

    2010-12-01

    A positive crossmatch indicates the presence of donor-specific alloantibodies and is associated with a graft loss rate of >80%; anti-ABO blood group antibodies develop in response to exposure to foreign blood groups, resulting in immediate graft loss. However, a desensitization protocol for highly HLA-sensitized and ABO-incompatible high-titer kidney transplantation has not yet been established. We treated 6 patients with high (≥1:512) anti-A/B antibody titers and 2 highly HLA-sensitized patients. Our immunosuppression protocol was initiated 1 month before surgery and included mycophenolate mofetil (1 g/d) and/or low-dose steroid (methylprednisolone 8 mg/d). Two doses of the anti-CD20 antibody rituximab (150 mg/m(2)) were administered 2 weeks before and on the day of transplantation. We performed antibody removal with 6-12 sessions of plasmapheresis (plasma exchange or double-filtration plasmapheresis) before transplantation. Splenectomy was also performed on the day of transplantation. Postoperative immunosuppression followed the same regimen as ABO-compatible cases, in which calcineurin inhibitors were initiated 3 days before transplantation, combined with 2 doses of basiliximab. Of the 8 patients, 7 subsequently underwent successful living-donor kidney transplantation. Follow-up of our recipients showed that the patient and graft survival rates were 100%. Acute cellular rejection and antibody-mediated rejection episodes occurred in 1 of the 7 recipients. These findings suggest that our immunosuppression regimen consisting of rituximab infusions, splenectomy, plasmapheresis, and pharmacologic immunosuppression may prove to be effective as a desensitization protocol for highly HLA-sensitized and ABO-incompatible high-titer kidney transplantation. Copyright © 2010 Elsevier Inc. All rights reserved.

  13. Highly sensitive straightness measurement system using a ball-lens

    International Nuclear Information System (INIS)

    Lee, Minho; Yang, Hyun-Ik; Cho, Nahm-Gyoo

    2016-01-01

    In this paper, a new and simple optical technique to accurately measure the straightness errors of a linear stage is proposed. To improve the performance, including the measurement sensitivity and resolution of the measurement system, and to simultaneously measure two-dimensional straightness errors (2D straightness errors), an optical system was designed using a laser, a retro-reflector, a ball-lens, and a two-dimensional position sensitive detector (2D PSD). The characteristics of the measurement system were analytically and experimentally investigated. A prototype measurement system was manufactured based on the investigated results, and the performances of this system have been tested. The measuring performance of the system was easily improved by about 12 times using the proposed technique and it can be further improved. It is shown that the proposed technique can easily and effectively improve the performance of a conventional straightness measurement system based on the geometric optical method using a PSD. (paper)

  14. Highly Sensitive Cadmium Concentration Sensor Using Long Period Grating

    Directory of Open Access Journals (Sweden)

    A. S. Lalasangi

    2011-08-01

    Full Text Available In this paper we have proposed a simple and effective Long Period Grating chemical sensor for detecting the traces of Cadmium (Cd++ in drinking water at ppm level. Long Period gratings (LPG were fabricated by point-by-point technique with CO2 laser. We have characterized the LPG concentration sensor sensitivity for different solutions of Cd concentrations varying from 0.01 ppm to 0.04 ppm by injecting white Light source and observed transmitted spectra using Optical Spectrum Analyzer (OSA. Proper reagents have been used in the solutions for detection of the Cd species. The overall shift in wavelength is 10 nm when surrounding medium gradually changed from water to 0.04 ppm of cadmium concentrations. A comparative study has been done using sophisticated spectroscopic atomic absorption spectrometer (AAS and Inductively Coupled Plasma (ICP instruments. The spectral sensitivity enhancement was done by modifying grating surface with gold nanoparticles.

  15. Highly sensitive BTX detection using surface functionalized QCM sensor

    Energy Technology Data Exchange (ETDEWEB)

    Bozkurt, Asuman Aşıkoğlu; Özdemir, Okan; Altındal, Ahmet, E-mail: altindal@yildiz.edu.tr [Department of Physics, Yildiz Technical University, Davutpasa, 34210 Istanbul (Turkey)

    2016-03-25

    A novel organic compound was designed and successfully synthesized for the fabrication of QCM based sensors to detect the low concentrations of BTX gases in indoor air. The effect of the long-range electron orbital delocalization on the BTX vapour sensing properties of azo-bridged Pcs based chemiresistor-type sensors have also been investigated in this work. The sensing behaviour of the film for the online detection of volatile organic solvent vapors was investigated by utilizing an AT-cut quartz crystal resonator. It was observed that the adsorption of the target molecules on the coating surface cause a reversible negative frequency shift of the resonator. Thus, a variety of solvent vapors can be detected by using the phthalocyanine film as sensitive coating, with sensitivity in the ppm range and response times in the order of several seconds depending on the molecular structure of the organic solvent.

  16. Multiple enhancement of luminol electrochemiluminescence using electrodes functionalized with titania nanotubes and platinum black: ultrasensitive determination of hydrogen peroxide, resveratrol, and dopamine

    International Nuclear Information System (INIS)

    Ming, Liang; Peng, Tingting; Tu, Yifeng

    2016-01-01

    We describe a substantial improvement of the electrochemiluminescence (ECL) of luminol which is widely used in flow injection analysis (FIA). It is based on synchronous dual sensitization of ECL by using titania nanotubes (TiNTs) and platinum black (PB). A piece of indium tin oxide (ITO) glass functionalized with TiNTs acts as the first working electrode, and a PB-modified platinum plate serves as the second one. By applying two constant potentials to the two electrodes, strong and consecutive ECL emission of luminol is obtained. The system works well in assays as shown for the successful quantitation of hydrogen peroxide (H 2 O 2 ), of the antioxidant resveratrol, and of the neutrotransmitter dopamine (DA) in spiked human serum samples. The detection limits for these three species (at a signal-to-noise ratio of 3) are as low as 66 pM (H 2 O 2 ), 22 nM (resveratrol), and 30 nM (DA). Recoveries in assays of DA in spiked serum range from 97.3 to 105.4 %. In our perception, the technique of dual sensitization represents a substantial improvement of the detection limits of ECL assays. (author)

  17. Signal-on electrochemiluminescence biosensor for microRNA-319a detection based on two-stage isothermal strand-displacement polymerase reaction.

    Science.gov (United States)

    Wang, Minghui; Zhou, Yunlei; Yin, Huanshun; Jiang, Wenjing; Wang, Haiyan; Ai, Shiyun

    2018-06-01

    MicroRNAs play crucial role in regulating gene expression in organism, thus it is very necessary to exploit an efficient method for the sensitive and specific detection of microRNA. Herein, a signal-on electrochemiluminescence biosensor was fabricated for microRNA-319a detection based on two-stage isothermal strand-displacement polymerase reaction (ISDPR). In the presence of target microRNA, amounts of trigger DNA could be generated by the first ISDPR. Then, the trigger DNA and the primer hybridized simultaneously with the hairpin probe to open the stem of the probe, and then the ECL signal will be emitted. In the presence of phi29 DNA polymerase and dNTPs, the trigger DNA could be displaced to initiate a new cycle which was the second ISDPR. Due to the two-stage amplification, this method presented excellent detection sensitivity with a low detection limit of 0.14 fM. Moreover, the applicability of the developed method was demonstrated by detecting the change of microRNA-319a content in the leaves of rice seedlings after the rice seeds were incubated with chemical mutagen of ethyl methanesulfonate. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Antibody Desensitization Therapy in Highly Sensitized Lung Transplant Candidates

    Science.gov (United States)

    Snyder, L. D.; Gray, A. L.; Reynolds, J. M.; Arepally, G. M.; Bedoya, A.; Hartwig, M. G.; Davis, R. D.; Lopes, K. E.; Wegner, W. E.; Chen, D. F.; Palmer, S. M.

    2015-01-01

    As HLAs antibody detection technology has evolved, there is now detailed HLA antibody information available on prospective transplant recipients. Determining single antigen antibody specificity allows for a calculated panel reactive antibodies (cPRA) value, providing an estimate of the effective donor pool. For broadly sensitized lung transplant candidates (cPRA ≥ 80%), our center adopted a pretransplant multimodal desensitization protocol in an effort to decrease the cPRA and expand the donor pool. This desensitization protocol included plasmapheresis, solumedrol, bortezomib and rituximab given in combination over 19 days followed by intravenous immunoglobulin. Eight of 18 candidates completed therapy with the primary reasons for early discontinuation being transplant (by avoiding unacceptable antigens) or thrombocytopenia. In a mixed-model analysis, there were no significant changes in PRA or cPRA changes over time with the protocol. A sub-analysis of the median fluorescence intensity (MFI) change indicated a small decline that was significant in antibodies with MFI 5000–10 000. Nine of 18 candidates subsequently had a transplant. Posttransplant survival in these nine recipients was comparable to other pretransplant-sensitized recipients who did not receive therapy. In summary, an aggressive multi-modal desensitization protocol does not significantly reduce pretransplant HLA antibodies in a broadly sensitized lung transplant candidate cohort. PMID:24666831

  19. Field-amplified sample stacking capillary electrophoresis with electrochemiluminescence applied to the determination of illicit drugs on banknotes.

    Science.gov (United States)

    Xu, Yuanhong; Gao, Ying; Wei, Hui; Du, Yan; Wang, Erkang

    2006-05-19

    Capillary electrophoresis (CE) with Ru(bpy)3(2+) electrochemiluminescence (ECL) detection system was established to the determination of contamination of banknotes with controlled drugs and a high efficiency on-column field-amplified sample stacking (FASS) technique was also optimized to increase the ECL intensity. The method was illustrated using heroin and cocaine, which are two typical and popular illicit drugs. Highest sample stacking was obtained when 0.01 mM acetic acid was chosen for sample dissolution with electrokinetical injection for 6 s at 17 kV. Under the optimized conditions: ECL detection at 1.2 V, separation voltage 10.0 kV, 20 mM phosphate-acetate (pH 7.2) as running buffer, 5 mM Ru(bpy)3(2+) with 50 mM phosphate-acetate (pH 7.2) in the detection cell, the standard curves were linear in the range of 7.50x10(-8) to 1.00x10(-5) M for heroin and 2.50x10(-7) to 1.00x10(-4) M for cocaine and detection limits of 50 nM for heroin and 60 nM for cocaine were achieved (S/N = 3), respectively. Relative standard derivations of the ECL intensity and the migration time were 3.50 and 0.51% for heroin and 4.44 and 0.12% for cocaine, respectively. The developed method was successfully applied to the determination of heroin and cocaine on illicit drug contaminated banknotes without any damage of the paper currency. A baseline resolution for heroin and cocaine was achieved within 6 min.

  20. A High-Sensitivity Current Sensor Utilizing CrNi Wire and Microfiber Coils

    Directory of Open Access Journals (Sweden)

    Xiaodong Xie

    2014-05-01

    Full Text Available We obtain an extremely high current sensitivity by wrapping a section of microfiber on a thin-diameter chromium-nickel wire. Our detected current sensitivity is as high as 220.65 nm/A2 for a structure length of only 35 μm. Such sensitivity is two orders of magnitude higher than the counterparts reported in the literature. Analysis shows that a higher resistivity or/and a thinner diameter of the metal wire may produce higher sensitivity. The effects of varying the structure parameters on sensitivity are discussed. The presented structure has potential for low-current sensing or highly electrically-tunable filtering applications.

  1. High-resolution, high-sensitivity NMR of nano-litre anisotropic samples by coil spinning

    Energy Technology Data Exchange (ETDEWEB)

    Sakellariou, D [CEA Saclay, DSM, DRECAM, SCM, Lab Struct and Dynam Resonance Magnet, CNRS URA 331, F-91191 Gif Sur Yvette, (France); Le Goff, G; Jacquinot, J F [CEA Saclay, DSM, DRECAM, SPEC: Serv Phys Etat Condense, CNRS URA 2464, F-91191 Gif Sur Yvette, (France)

    2007-07-01

    Nuclear magnetic resonance (NMR) can probe the local structure and dynamic properties of liquids and solids, making it one of the most powerful and versatile analytical methods available today. However, its intrinsically low sensitivity precludes NMR analysis of very small samples - as frequently used when studying isotopically labelled biological molecules or advanced materials, or as preferred when conducting high-throughput screening of biological samples or 'lab-on-a-chip' studies. The sensitivity of NMR has been improved by using static micro-coils, alternative detection schemes and pre-polarization approaches. But these strategies cannot be easily used in NMR experiments involving the fast sample spinning essential for obtaining well-resolved spectra from non-liquid samples. Here we demonstrate that inductive coupling allows wireless transmission of radio-frequency pulses and the reception of NMR signals under fast spinning of both detector coil and sample. This enables NMR measurements characterized by an optimal filling factor, very high radio-frequency field amplitudes and enhanced sensitivity that increases with decreasing sample volume. Signals obtained for nano-litre-sized samples of organic powders and biological tissue increase by almost one order of magnitude (or, equivalently, are acquired two orders of magnitude faster), compared to standard NMR measurements. Our approach also offers optimal sensitivity when studying samples that need to be confined inside multiple safety barriers, such as radioactive materials. In principle, the co-rotation of a micrometer-sized detector coil with the sample and the use of inductive coupling (techniques that are at the heart of our method) should enable highly sensitive NMR measurements on any mass-limited sample that requires fast mechanical rotation to obtain well-resolved spectra. The method is easy to implement on a commercial NMR set-up and exhibits improved performance with miniaturization, and we

  2. From Molecular Design to Co-sensitization; High performance indole based photosensitizers for dye-sensitized solar cells

    International Nuclear Information System (INIS)

    Babu, Dickson D.; Su, Rui; El-Shafei, Ahmed; Adhikari, Airody Vasudeva

    2016-01-01

    displays promising photovoltaic results and exhibited an enhanced efficiency of 8.06%. Further, good agreement between the calculated and experimental results showcase the precision of the energy functional and basis set utilized in this study. All these findings provide a deeper insight and better understanding into the intricacies involved in the design of superior co-sensitizers for development of highly efficient DSSCs.

  3. New approach to 3-D, high sensitivity, high mass resolution space plasma composition measurements

    International Nuclear Information System (INIS)

    McComas, D.J.; Nordholt, J.E.

    1990-01-01

    This paper describes a new type of 3-D space plasma composition analyzer. The design combines high sensitivity, high mass resolution measurements with somewhat lower mass resolution but even higher sensitivity measurements in a single compact and robust design. While the lower resolution plasma measurements are achieved using conventional straight-through time-of-flight mass spectrometry, the high mass resolution measurements are made by timing ions reflected in a linear electric field (LEF), where the restoring force that an ion experiences is proportional to the depth it travels into the LEF region. Consequently, the ion's equation of motion in that dimension is that of a simple harmonic oscillator and its travel time is simply proportional to the square root of the ion's mass/charge (m/q). While in an ideal LEF, the m/q resolution can be arbitrarily high, in a real device the resolution is limited by the field linearity which can be achieved. In this paper we describe how a nearly linear field can be produced and discuss how the design can be optimized for various different plasma regimes and spacecraft configurations

  4. High mass resolution time of flight mass spectrometer for measuring products in heterogeneous catalysis in highly sensitive microreactors

    DEFF Research Database (Denmark)

    Andersen, Thomas; Jensen, Robert; Christensen, M. K.

    2012-01-01

    We demonstrate a combined microreactor and time of flight system for testing and characterization of heterogeneous catalysts with high resolution mass spectrometry and high sensitivity. Catalyst testing is performed in silicon-based microreactors which have high sensitivity and fast thermal...

  5. Solution Processable Electrochemiluminescent Ion Gels for Flexible, Low Voltage, Emissive Displays on Plastic

    Science.gov (United States)

    Moon, Hong Chul; Lodge, Timothy P.; Frisbie, C. Daniel

    2014-03-01

    We have expanded the functionality of ion gels and successfully demonstrated low voltage, flexible electrochemiluminescent (ECL) devices using patterned ECL gels. An ECL device composed of only an emissive gel and two electrodes was fabricated on an ITO-coated substrate by solution casting the ECL gel and brush-painting the top silver electrode. The device turned on at an AC voltage as low as 2.6 V (-1.3 V ~ +1.3 V) and showed a relatively rapid response (sub-ms). Also, we varied the mechanical properties of the ECL gel simply by substituting polystyrene-block-poly(methyl methacrylate)-block-polystyrene (SMS) with commercially available poly(vinylidene fluoride-co-hexafluoropropylene) (P(VDF-co-HFP)), enabling the fabrication of flexible ECL devices on any target substrate by the ``cut-and-stick'' strategy. This simple, rubbery ECL gel should be attractive for flexible electronics applications such as displays on packaging.

  6. Electrochemiluminescence Biosensor Based on Thioglycolic Acid-Capped CdSe QDs for Sensing Glucose

    Directory of Open Access Journals (Sweden)

    Eun-Young Jung

    2016-01-01

    Full Text Available In order to detect low level glucose concentration, an electrochemiluminescence (ECL biosensor based on TGA-capped CdSe quantum dots (QDs was fabricated by the immobilization of CdSe QDs after modifying the surface of a glassy carbon electrode (GCE with 4-aminothiophenol diazonium salts by the electrochemical method. For the detection of glucose concentration, glucose oxidase (GOD was immobilized onto the fabricated CdSe QDs-modified electrode. The fabricated ECL biosensor based on TGA-capped CdSe QDs was characterized using a scanning electron microscope (SEM, UV-vis spectrophotometry, transmission electron microscopy (TEM, a fluorescence spectrometer (PL, and cyclic voltammetry (CV. The fabricated ECL biosensor based on TGA-capped CdSe QDs is suitable for the detection of glucose concentrations in real human blood samples.

  7. Analysis of Cyberbullying Sensitivity Levels of High School Students and Their Perceived Social Support Levels

    Science.gov (United States)

    Akturk, Ahmet Oguz

    2015-01-01

    Purpose: The purpose of this paper is to determine the cyberbullying sensitivity levels of high school students and their perceived social supports levels, and analyze the variables that predict cyberbullying sensitivity. In addition, whether cyberbullying sensitivity levels and social support levels differed according to gender was also…

  8. The Relationship between Ethical Sensitivity, High Ability and Gender in Higher Education Students

    Science.gov (United States)

    Schutte, Ingrid; Wolfensberger, Marca; Tirri, Kirsi

    2014-01-01

    This study examined the ethical sensitivity of high-ability undergraduate students (n=731) in the Netherlands who completed the 28-item Ethical Sensitivity Scale Questionnaire (ESSQ) developed by Tirri & Nokelainen (2007; 2011). The ESSQ is based on Narvaez' (2001) operationalization of ethical sensitivity in seven dimensions. The following…

  9. Platinum decorated carbon nanotubes for highly sensitive amperometric glucose sensing

    International Nuclear Information System (INIS)

    Xie Jining; Wang Shouyan; Aryasomayajula, L; Varadan, V K

    2007-01-01

    Fine platinum nanoparticles (1-5 nm in diameter) were deposited on functionalized multi-walled carbon nanotubes (MWNTs) through a decoration technique. A novel type of enzymatic Pt/MWNTs paste-based mediated glucose sensor was fabricated. Electrochemical measurements revealed a significantly improved sensitivity (around 52.7 μA mM -1 cm -2 ) for glucose sensing without using any picoampere booster or Faraday cage. In addition, the calibration curve exhibited a good linearity in the range of 1-28 mM of glucose concentration. Transmission electron microscopy (TEM) and x-ray photoelectron spectroscopy (XPS) were performed to investigate the nanoscale structure and the chemical bonding information of the Pt/MWNTs paste-based sensing material, respectively. The improved sensitivity of this novel glucose sensor could be ascribed to its higher electroactive surface area, enhanced electron transfer, efficient enzyme immobilization, unique interaction in nanoscale and a synergistic effect on the current signal from possible multi-redox reactions

  10. High Sensitivity TSS Prediction: Estimates of Locations Where TSS Cannot Occur

    KAUST Repository

    Schaefer, Ulf; Kodzius, Rimantas; Kai, Chikatoshi; Kawai, Jun; Carninci, Piero; Hayashizaki, Yoshihide; Bajic, Vladimir B.

    2013-01-01

    from mouse and human genomes, we developed a methodology that allows us, by performing computational TSS prediction with very high sensitivity, to annotate, with a high accuracy in a strand specific manner, locations of mammalian genomes that are highly

  11. An electrochemiluminescence-based fibre optic biosensor for choline flow injection analysis.

    Science.gov (United States)

    Tsafack, V C; Marquette, C A; Leca, B; Blum, L J

    2000-01-01

    A fibre optic biosensor based on luminol electrochemiluminescence (ECL) integrated in a flow injection analysis (FIA) system was developed for the detection of choline. The electrochemiluminescence of luminol was generated by a glassy carbon electrode polarised at +425 mV vs. a platinum pseudo-reference electrode. Choline oxidase (Chx) was immobilised either covalently on polyamide (ABC type) or on UltraBind preactivated membranes, or by physical entrapment in a photo-cross-linkable poly(vinyl alcohol) polymer (PVA-SbQ) alone or after absorption on a weak anion exchanger, DEAE (diethylaminoethyl) Sepharose. The optimisation of the reaction conditions and physicochemical parameters influencing the FIA biosensor response demonstrated that the choline biosensor exhibited the best performances in a 30 mM veronal buffer containing 30 mM KCl and 1.5 mM MgCl2, at pH 9. The use of a 0.5 ml min-1 flow rate enabled the measurement of choline by the membrane-based ECL biosensors in 8 or 5 min, with ABC or UltraBind membranes, respectively, whereas the measurement required only 3 min with the DEAE-PVA system. For comparison, the detection of choline was performed with Chx immobilised using the four different supports. The best performances were obtained with the DEAE-PVA-Chx sensing layer, which allowed a detection limit of 10 pmol, whereas with the ABC, the UltraBind and the PVA systems, the detection limits were 300 pmol, 75 pmol and 220 pmol, respectively. The DEAE-based system also exhibited a good operational stability since 160 repeated measurements of 3 nmol of choline could be performed with an RSD of 4.5% whereas the stability under the best conditions was 45 assays with the other supports.

  12. Highly sensitive urea sensing with ion-irradiated polymer foils

    International Nuclear Information System (INIS)

    Fink, Dietmar; Muñoz Hernandez, Gerardo; Alfonta, Lital

    2012-01-01

    Recently we prepared urea-sensors by attaching urease to the inner walls of etched ion tracks within thin polymer foil. Here, alternative track-based sensor configurations are examined where the enzyme remained in solution. The conductivities of systems consisting of two parallel irradiated polymer foils and confining different urea/urease mixtures in between were examined. The correlations between conductivity and urea concentration differed strongly for foils with unetched and etched tracks, which points at different sensing mechanisms – tentatively attributed to the adsorption of enzymatic reaction products on the latent track entrances and to the enhanced conductivity of reaction product-filled etched tracks, respectively. All examined systems enable in principle, urea sensing. They point at the possibility of sensor cascade construction for more sensitive or selective sensor systems.

  13. A new compact, high sensitivity neutron imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Caillaud, T.; Landoas, O.; Briat, M.; Rosse, B.; Thfoin, I.; Philippe, F.; Casner, A.; Bourgade, J. L.; Disdier, L. [CEA, DAM, DIF,F-91297 Arpajon (France); Glebov, V. Yu.; Marshall, F. J.; Sangster, T. C. [Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623-1299 (United States); Park, H. S.; Robey, H. F.; Amendt, P. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2012-10-15

    We have developed a new small neutron imaging system (SNIS) diagnostic for the OMEGA laser facility. The SNIS uses a penumbral coded aperture and has been designed to record images from low yield (10{sup 9}-10{sup 10} neutrons) implosions such as those using deuterium as the fuel. This camera was tested at OMEGA in 2009 on a rugby hohlraum energetics experiment where it recorded an image at a yield of 1.4 Multiplication-Sign 10{sup 10}. The resolution of this image was 54 {mu}m and the camera was located only 4 meters from target chamber centre. We recently improved the instrument by adding a cooled CCD camera. The sensitivity of the new camera has been fully characterized using a linear accelerator and a {sup 60}Co {gamma}-ray source. The calibration showed that the signal-to-noise ratio could be improved by using raw binning detection.

  14. A new compact, high sensitivity neutron imaging system

    International Nuclear Information System (INIS)

    Caillaud, T.; Landoas, O.; Briat, M.; Rossé, B.; Thfoin, I.; Philippe, F.; Casner, A.; Bourgade, J. L.; Disdier, L.; Glebov, V. Yu.; Marshall, F. J.; Sangster, T. C.; Park, H. S.; Robey, H. F.; Amendt, P.

    2012-01-01

    We have developed a new small neutron imaging system (SNIS) diagnostic for the OMEGA laser facility. The SNIS uses a penumbral coded aperture and has been designed to record images from low yield (10 9 –10 10 neutrons) implosions such as those using deuterium as the fuel. This camera was tested at OMEGA in 2009 on a rugby hohlraum energetics experiment where it recorded an image at a yield of 1.4 × 10 10 . The resolution of this image was 54 μm and the camera was located only 4 meters from target chamber centre. We recently improved the instrument by adding a cooled CCD camera. The sensitivity of the new camera has been fully characterized using a linear accelerator and a 60 Co γ-ray source. The calibration showed that the signal-to-noise ratio could be improved by using raw binning detection.

  15. High fat diet-fed obese rats are highly sensitive to doxorubicin-induced cardiotoxicity

    International Nuclear Information System (INIS)

    Mitra, Mayurranjan S.; Donthamsetty, Shashikiran; White, Brent; Mehendale, Harihara M.

    2008-01-01

    Often, chemotherapy by doxorubicin (Adriamycin) is limited due to life threatening cardiotoxicity in patients during and posttherapy. Recently, we have shown that moderate diet restriction remarkably protects against doxorubicin-induced cardiotoxicity. This cardioprotection is accompanied by decreased cardiac oxidative stress and triglycerides and increased cardiac fatty-acid oxidation, ATP synthesis, and upregulated JAK/STAT3 pathway. In the current study, we investigated whether a physiological intervention by feeding 40% high fat diet (HFD), which induces obesity in male Sprague-Dawley rats (250-275 g), sensitizes to doxorubicin-induced cardiotoxicity. A LD 10 dose (8 mg doxorubicin/kg, ip) administered on day 43 of the HFD feeding regimen led to higher cardiotoxicity, cardiac dysfunction, lipid peroxidation, and 80% mortality in the obese (OB) rats in the absence of any significant renal or hepatic toxicity. Doxorubicin toxicokinetics studies revealed no change in accumulation of doxorubicin and doxorubicinol (toxic metabolite) in the normal diet-fed (ND) and OB hearts. Mechanistic studies revealed that OB rats are sensitized due to: (1) higher oxyradical stress leading to upregulation of uncoupling proteins 2 and 3, (2) downregulation of cardiac peroxisome proliferators activated receptor-α, (3) decreased plasma adiponectin levels, (4) decreased cardiac fatty-acid oxidation (666.9 ± 14.0 nmol/min/g heart in ND versus 400.2 ± 11.8 nmol/min/g heart in OB), (5) decreased mitochondrial AMP-α2 protein kinase, and (6) 86% drop in cardiac ATP levels accompanied by decreased ATP/ADP ratio after doxorubicin administration. Decreased cardiac erythropoietin and increased SOCS3 further downregulated the cardioprotective JAK/STAT3 pathway. In conclusion, HFD-induced obese rats are highly sensitized to doxorubicin-induced cardiotoxicity by substantially downregulating cardiac mitochondrial ATP generation, increasing oxidative stress and downregulating the JAK/STAT3

  16. Highly sensitive assay for tyrosine hydroxylase activity by high-performance liquid chromatography.

    Science.gov (United States)

    Nagatsu, T; Oka, K; Kato, T

    1979-07-21

    A highly sensitive assay for tyrosine hydroxylase (TH) activity by high-performance liquid chromatography (HPLC) with amperometric detection was devised based on the rapid isolation of enzymatically formed DOPA by a double-column procedure, the columns fitted together sequentially (the top column of Amberlite CG-50 and the bottom column of aluminium oxide). DOPA was adsorbed on the second aluminium oxide column, then eluted with 0.5 M hydrochloric acid, and assayed by HPLC with amperometric detection. D-Tyrosine was used for the control. alpha-Methyldopa was added to the incubation mixture as an internal standard after incubation. This assay was more sensitive than radioassays and 5 pmol of DOPA formed enzymatically could be measured in the presence of saturating concentrations of tyrosine and 6-methyltetrahydropterin. The TH activity in 2 mg of human putamen could be easily measured, and this method was found to be particularly suitable for the assay of TH activity in a small number of nuclei from animal and human brain.

  17. Nitrogen detected TROSY at high field yields high resolution and sensitivity for protein NMR

    International Nuclear Information System (INIS)

    Takeuchi, Koh; Arthanari, Haribabu; Shimada, Ichio; Wagner, Gerhard

    2015-01-01

    Detection of 15 N in multidimensional NMR experiments of proteins has sparsely been utilized because of the low gyromagnetic ratio (γ) of nitrogen and the presumed low sensitivity of such experiments. Here we show that selecting the TROSY components of proton-attached 15 N nuclei (TROSY 15 N H ) yields high quality spectra in high field magnets (>600 MHz) by taking advantage of the slow 15 N transverse relaxation and compensating for the inherently low 15 N sensitivity. The 15 N TROSY transverse relaxation rates increase modestly with molecular weight but the TROSY gain in peak heights depends strongly on the magnetic field strength. Theoretical simulations predict that the narrowest line width for the TROSY 15 N H component can be obtained at 900 MHz, but sensitivity reaches its maximum around 1.2 GHz. Based on these considerations, a 15 N-detected 2D 1 H– 15 N TROSY-HSQC ( 15 N-detected TROSY-HSQC) experiment was developed and high-quality 2D spectra were recorded at 800 MHz in 2 h for 1 mM maltose-binding protein at 278 K (τ c  ∼ 40 ns). Unlike for 1 H detected TROSY, deuteration is not mandatory to benefit 15 N detected TROSY due to reduced dipolar broadening, which facilitates studies of proteins that cannot be deuterated, especially in cases where production requires eukaryotic expression systems. The option of recording 15 N TROSY of proteins expressed in H 2 O media also alleviates the problem of incomplete amide proton back exchange, which often hampers the detection of amide groups in the core of large molecular weight proteins that are expressed in D 2 O culture media and cannot be refolded for amide back exchange. These results illustrate the potential of 15 N H -detected TROSY experiments as a means to exploit the high resolution offered by high field magnets near and above 1 GHz

  18. Nitrogen detected TROSY at high field yields high resolution and sensitivity for protein NMR

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Koh [National Institute for Advanced Industrial Science and Technology, Molecular Profiling Research Center for Drug Discovery (Japan); Arthanari, Haribabu [Harvard Medical School, Department of Biochemistry and Molecular Pharmacology (United States); Shimada, Ichio, E-mail: shimada@iw-nmr.f.u-tokyo.ac.jp [National Institute for Advanced Industrial Science and Technology, Molecular Profiling Research Center for Drug Discovery (Japan); Wagner, Gerhard, E-mail: gerhard-wagner@hms.harvard.edu [Harvard Medical School, Department of Biochemistry and Molecular Pharmacology (United States)

    2015-12-15

    Detection of {sup 15}N in multidimensional NMR experiments of proteins has sparsely been utilized because of the low gyromagnetic ratio (γ) of nitrogen and the presumed low sensitivity of such experiments. Here we show that selecting the TROSY components of proton-attached {sup 15}N nuclei (TROSY {sup 15}N{sub H}) yields high quality spectra in high field magnets (>600 MHz) by taking advantage of the slow {sup 15}N transverse relaxation and compensating for the inherently low {sup 15}N sensitivity. The {sup 15}N TROSY transverse relaxation rates increase modestly with molecular weight but the TROSY gain in peak heights depends strongly on the magnetic field strength. Theoretical simulations predict that the narrowest line width for the TROSY {sup 15}N{sub H} component can be obtained at 900 MHz, but sensitivity reaches its maximum around 1.2 GHz. Based on these considerations, a {sup 15}N-detected 2D {sup 1}H–{sup 15}N TROSY-HSQC ({sup 15}N-detected TROSY-HSQC) experiment was developed and high-quality 2D spectra were recorded at 800 MHz in 2 h for 1 mM maltose-binding protein at 278 K (τ{sub c} ∼ 40 ns). Unlike for {sup 1}H detected TROSY, deuteration is not mandatory to benefit {sup 15}N detected TROSY due to reduced dipolar broadening, which facilitates studies of proteins that cannot be deuterated, especially in cases where production requires eukaryotic expression systems. The option of recording {sup 15}N TROSY of proteins expressed in H{sub 2}O media also alleviates the problem of incomplete amide proton back exchange, which often hampers the detection of amide groups in the core of large molecular weight proteins that are expressed in D{sub 2}O culture media and cannot be refolded for amide back exchange. These results illustrate the potential of {sup 15}N{sub H}-detected TROSY experiments as a means to exploit the high resolution offered by high field magnets near and above 1 GHz.

  19. Applications of molecules as high-resolution, high-sensitivity threshold electron detectors

    International Nuclear Information System (INIS)

    Chutjian, A.

    1991-01-01

    The goal of the work under the contract entitled ''Applications of Molecules as High-Resolution, High-Sensitivity Threshold Electron Detectors'' (DoE IAA No. DE-AI01-83ER13093 Mod. A006) was to explore the electron attachment properties of a variety of molecules at electron energies not accessible by other experimental techniques. As a result of this work, not only was a large body of basic data measured on attachment cross sections and rate constants; but also extensive theoretical calculations were carried out to verify the underlying phenomenon of s-wave attachment. Important outgrowths of this week were also realized in other areas of research. The basic data have applications in fields such as combustion, soot reduction, rocket-exhaust modification, threshold photoelectron spectroscopy, and trace species detection

  20. An application of impediography to the high sensitivity and high resolution identification of structural damage

    International Nuclear Information System (INIS)

    Zhao, L; Yang, J; Semperlotti, F; Wang, K W

    2015-01-01

    In this study we explore the use of impediographic techniques to perform damage detection in plate-like metal structures. Impediography relies on the piezo-resistive coupling of the host structure to reconstruct high sensitivity and high resolution maps of the internal electrical conductivity. By exploiting localized strain perturbations generated via focused acoustic waves, the piezo-resistive coupling allows extracting a set of linearly independent boundary voltage data that drastically reduces the ill-conditioning of the inverse problem, therefore increasing the performance. The localized perturbation is achieved by leveraging the concept of frequency selective structure (FSS), that is a dynamically tailored structural element enabling the required acoustic focusing via vibration localization. Based on the FSS approach, the impediographic technique is numerically tested to investigate the performance of the combined approach for structural damage detection. The effects of practical implementation issues, such as limited perturbations and limited boundary data, are also explored. (paper)

  1. Storing quantum information in spins and high-sensitivity ESR.

    Science.gov (United States)

    Morton, John J L; Bertet, Patrice

    2018-02-01

    Quantum information, encoded within the states of quantum systems, represents a novel and rich form of information which has inspired new types of computers and communications systems. Many diverse electron spin systems have been studied with a view to storing quantum information, including molecular radicals, point defects and impurities in inorganic systems, and quantum dots in semiconductor devices. In these systems, spin coherence times can exceed seconds, single spins can be addressed through electrical and optical methods, and new spin systems with advantageous properties continue to be identified. Spin ensembles strongly coupled to microwave resonators can, in principle, be used to store the coherent states of single microwave photons, enabling so-called microwave quantum memories. We discuss key requirements in realising such memories, including considerations for superconducting resonators whose frequency can be tuned onto resonance with the spins. Finally, progress towards microwave quantum memories and other developments in the field of superconducting quantum devices are being used to push the limits of sensitivity of inductively-detected electron spin resonance. The state-of-the-art currently stands at around 65 spins per Hz, with prospects to scale down to even fewer spins. Copyright © 2017. Published by Elsevier Inc.

  2. Storing quantum information in spins and high-sensitivity ESR

    Science.gov (United States)

    Morton, John J. L.; Bertet, Patrice

    2018-02-01

    Quantum information, encoded within the states of quantum systems, represents a novel and rich form of information which has inspired new types of computers and communications systems. Many diverse electron spin systems have been studied with a view to storing quantum information, including molecular radicals, point defects and impurities in inorganic systems, and quantum dots in semiconductor devices. In these systems, spin coherence times can exceed seconds, single spins can be addressed through electrical and optical methods, and new spin systems with advantageous properties continue to be identified. Spin ensembles strongly coupled to microwave resonators can, in principle, be used to store the coherent states of single microwave photons, enabling so-called microwave quantum memories. We discuss key requirements in realising such memories, including considerations for superconducting resonators whose frequency can be tuned onto resonance with the spins. Finally, progress towards microwave quantum memories and other developments in the field of superconducting quantum devices are being used to push the limits of sensitivity of inductively-detected electron spin resonance. The state-of-the-art currently stands at around 65 spins per √{ Hz } , with prospects to scale down to even fewer spins.

  3. Highly sensitive DNA sensors based on cerium oxide nanorods

    Science.gov (United States)

    Nguyet, Nguyen Thi; Hai Yen, Le Thi; Van Thu, Vu; lan, Hoang; Trung, Tran; Vuong, Pham Hung; Tam, Phuong Dinh

    2018-04-01

    In this work, a CeO2 nanorod (NR)-based electrochemical DNA sensor was developed to identify Salmonella that causes food-borne infections. CeO2 NRs were synthesized without templates via a simple and unexpensive hydrothermal approach at 170 °C for 12 h by using CeO(NO3)3·6H2O as a Ce source. The DNA probe was immobilized onto the CeO2 NR-modified electrode through covalent attachment. The characteristics of the hybridized DNA were analyzed through electrochemical impedance spectroscopy (EIS) with [Fe(CN)6]3-/4- as a redox probe. Experimental results showed that electron transfer resistance (Ret) increased after the DNA probe was attached to the electrode surface and increased further after the DNA probe hybridized with its complementary sequence. A linear response of Ret to the target DNA concentration was found from 0.01 μM to 2 μM. The detection limit and sensitivity of the DNA sensor were 0.01 μM and 3362.1 Ω μM-1 cm-2, respectively. Various parameters, such as pH value, ionic strength, DNA probe concentration, and hybridization time, influencing DNA sensor responses were also investigated.

  4. Ultraselective electrochemiluminescence biosensor based on locked nucleic acid modified toehold-mediated strand displacement reaction and junction-probe.

    Science.gov (United States)

    Zhang, Xi; Zhang, Jing; Wu, Dongzhi; Liu, Zhijing; Cai, Shuxian; Chen, Mei; Zhao, Yanping; Li, Chunyan; Yang, Huanghao; Chen, Jinghua

    2014-12-07

    Locked nucleic acid (LNA) is applied in toehold-mediated strand displacement reaction (TMSDR) to develop a junction-probe electrochemiluminescence (ECL) biosensor for single-nucleotide polymorphism (SNP) detection in the BRCA1 gene related to breast cancer. More than 65-fold signal difference can be observed with perfectly matched target sequence to single-base mismatched sequence under the same conditions, indicating good selectivity of the ECL biosensor.

  5. Ultrasensitive Faraday cage-type electrochemiluminescence assay for femtomolar miRNA-141 via graphene oxide and hybridization chain reaction-assisted cascade amplification.

    Science.gov (United States)

    Lu, Jing; Wu, Lin; Hu, Yufang; Wang, Sui; Guo, Zhiyong

    2018-06-30

    In this study, a novel electrochemiluminescence (ECL) biosensor for sensitive detection of femtomolar miRNA-141 was constructed on the basis of Faraday cage-type strategy via graphene oxide (GO) and hybridization chain reaction (HCR)-assisted cascade amplification. A capture probe (CP) was immobilized on Fe 3 O 4 @SiO 2 @Au nanoparticles as capture unit, which could catch the miRNA-141, and the immobilization of the signal unit (Ru(phen) 3 2+ -HCR/GO) was allowed via nucleic acid hybridization. The prepared biosensor exhibited two advantages for signal amplification: firstly, GO could lap on the electrode surface directly, extending Outer Helmholtz Plane (OHP) of the sensor due to the large surface area and good electronic transport property; secondly, HCR-assisted cascade amplification was designed by anchoring all HCR products on the GO surface, then embedding Ru(phen) 3 2+ as a signal readout pathway. All these signal molecules could take part in electrochemical reactions, thus further enhancing the ECL signal drastically. Therefore, the proposed sensor constructed by integrating HCR with Faraday cage-type strategy displayed an ultrasensitive detection platform for the miRNA-141 with a low detection limit of 0.03 fM. In addition, this proposed biosensor provides a universal platform for analysis of other microRNAs. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Highly efficient and stable cyclometalated ruthenium(II) complexes as sensitizers for dye-sensitized solar cells

    International Nuclear Information System (INIS)

    Huang, Jian-Feng; Liu, Jun-Min; Su, Pei-Yang; Chen, Yi-Fan; Shen, Yong; Xiao, Li-Min; Kuang, Dai-Bin; Su, Cheng-Yong

    2015-01-01

    Highlights: • Four novel thiocyanate-free cyclometalated ruthenium sensitizer were conveniently synthesized. • The D-CF 3 -sensitized DSSCs show higher efficiency compared to N719 based cells. • The DSSCs based on D-CF 3 and D-bisCF 3 sensitizers exhibit excellent long-term stability. • The diverse cyclometalated Ru complexes can be developed as high-performance sensitizers for use in DSSC. - Abstract: Four novel thiocyanate-free cyclometallted Ru(II) complexes, D-bisCF 3 , D-CF 3 , D-OMe, and D-DPA, with two 4,4′-dicarboxylic acid-2,2′-bipyridine together with a functionalized phenylpyridine ancillary ligand, have been designed and synthesized. The effect of different substituents (R = bisCF 3 , CF 3 , OMe, and DPA) on the ancillary C^N ligand on the photophysical properties and photovoltaic performance is investigated. Under standard global AM 1.5 solar conditions, the device based on D-CF 3 sensitizer gives a higher conversion efficiency of 8.74% than those based on D-bisCF 3 , D-OMe, and D-DPA, which can be ascribed to its broad range of visible light absorption, appropriate localization of the frontier orbitals, weak hydrogen bonds between -CF 3 and -OH groups at the TiO 2 surface, moderate dye loading on TiO 2 , and high charge collection efficiency. Moreover, the D-bisCF 3 and D-CF 3 based DSSCs exhibit good stability under 100 mW cm −2 light soaking at 60 °C for 400 h

  7. Photoelastic colloidal gel for a high-sensitivity strain sensor

    Science.gov (United States)

    Pan, Hui; Chen, Zhixin; Zhu, Shenmin; Jiang, Chun; Zhang, Di

    2018-04-01

    Nanoparticles, having the ability to self-assemble into an ordered structure in their suspensions, analogous to liquid crystals, have attracted extensive attention. Herein, we report a new type of colloidal gel with an ordered crystal structure assembled from 1D and 2D nanoparticles. The material has high elasticity and, more interestingly, it shows significant photoelasticity. Its refractive index can be tuned under external stress and exhibits an ultra-wide dynamic range (Δn) of the order of 10-2. Due to the large Δn, the material shows an extremely high strain sensibility of 720 nm/ɛ, an order of magnitude higher than the reported ones.

  8. High-sensitivity mass spectrometry with a tandem accelerator

    International Nuclear Information System (INIS)

    Henning, W.

    1984-01-01

    The characteristic features of accelerator mass spectrometry are discussed. A short overview is given of the current status of mass spectrometry with high-energy (MeV/nucleon) heavy-ion accelerators. Emphasis is placed on studies with tandem accelerators and on future mass spectrometry of heavier isotopes with the new generation of higher-voltage tandems

  9. Correcting systematic errors in high-sensitivity deuteron polarization measurements

    NARCIS (Netherlands)

    Brantjes, N. P. M.; Dzordzhadze, V.; Gebel, R.; Gonnella, F.; Gray, F. E.; van der Hoek, D. J.; Imig, A.; Kruithof, W. L.; Lazarus, D. M.; Lehrach, A.; Lorentz, B.; Messi, R.; Moricciani, D.; Morse, W. M.; Noid, G. A.; Onderwater, C. J. G.; Ozben, C. S.; Prasuhn, D.; Sandri, P. Levi; Semertzidis, Y. K.; da Silva e Silva, M.; Stephenson, E. J.; Stockhorst, H.; Venanzoni, G.; Versolato, O. O.

    2012-01-01

    This paper reports deuteron vector and tensor beam polarization measurements taken to investigate the systematic variations due to geometric beam misalignments and high data rates. The experiments used the In-Beam Polarimeter at the KVI-Groningen and the EDDA detector at the Cooler Synchrotron COSY

  10. Variable high pressure processing sensitivities for GII human noroviruses

    Science.gov (United States)

    Human norovirus (HuNoV) is the leading cause of foodborne diseases worldwide. High pressure processing (HPP) is one of the most promising non-thermal technologies for decontamination of viral pathogens in foods. However, the survival of HuNoVs by HPP is poorly understood because these viruses cann...

  11. High Sensitivity Indium Phosphide Based Avalanche Photodiode Focal Plane Arrays, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — nLight has demonstrated highly-uniform APD arrays based on the highly sensitive InGaAs/InP material system. These results provide great promise for achieving the...

  12. Mass Spectrometry-based Assay for High Throughput and High Sensitivity Biomarker Verification

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Xuejiang; Tang, Keqi

    2017-06-14

    Searching for disease specific biomarkers has become a major undertaking in the biomedical research field as the effective diagnosis, prognosis and treatment of many complex human diseases are largely determined by the availability and the quality of the biomarkers. A successful biomarker as an indicator to a specific biological or pathological process is usually selected from a large group of candidates by a strict verification and validation process. To be clinically useful, the validated biomarkers must be detectable and quantifiable by the selected testing techniques in their related tissues or body fluids. Due to its easy accessibility, protein biomarkers would ideally be identified in blood plasma or serum. However, most disease related protein biomarkers in blood exist at very low concentrations (<1ng/mL) and are “masked” by many none significant species at orders of magnitude higher concentrations. The extreme requirements of measurement sensitivity, dynamic range and specificity make the method development extremely challenging. The current clinical protein biomarker measurement primarily relies on antibody based immunoassays, such as ELISA. Although the technique is sensitive and highly specific, the development of high quality protein antibody is both expensive and time consuming. The limited capability of assay multiplexing also makes the measurement an extremely low throughput one rendering it impractical when hundreds to thousands potential biomarkers need to be quantitatively measured across multiple samples. Mass spectrometry (MS)-based assays have recently shown to be a viable alternative for high throughput and quantitative candidate protein biomarker verification. Among them, the triple quadrupole MS based assay is the most promising one. When it is coupled with liquid chromatography (LC) separation and electrospray ionization (ESI) source, a triple quadrupole mass spectrometer operating in a special selected reaction monitoring (SRM) mode

  13. Self-powered neutron detector of high sensitivity

    International Nuclear Information System (INIS)

    Brixy, H.; Spillekothen, H.G.; Benninghofen, G.; Serafin, N.

    1983-01-01

    A self-powered neutron detector is proposed, consisting of three concentrically arranged electrically conducting tubes; where the central one forms the emitter and the inner and outer ones form the collector and where the tubes are electrically insulated from each other by insulating material. The emitter consists of a material with a high absorption cross-section for thermal neutrons, particularly of gadolinium, and is provided with an auxiliary emitter layer on the inside or the outside. With suitable dimensions and material, the auxiliary emitter layer increases the yield of electrons. (orig./HP) [de

  14. An Underwater Acoustic Vector Sensor with High Sensitivity and Broad Band

    Directory of Open Access Journals (Sweden)

    Hu Zhang

    2014-05-01

    Full Text Available Recently, acoustic vector sensor that use accelerators as sensing elements are widely used in underwater acoustic engineering, but the sensitivity of which at low frequency band is usually lower than -220 dB. In this paper, using a piezoelectric trilaminar optimized low frequency sensing element, we designed a high sensitivity internal placed ICP piezoelectric accelerometer as sensing element. Through structure optimization, we made a high sensitivity, broadband, small scale vector sensor. The working band is 10-2000 Hz, sound pressure sensitivity is -185 dB (at 100 Hz, outer diameter is 42 mm, length is 80 mm.

  15. Serine Protease Zymography: Low-Cost, Rapid, and Highly Sensitive RAMA Casein Zymography.

    Science.gov (United States)

    Yasumitsu, Hidetaro

    2017-01-01

    To detect serine protease activity by zymography, casein and CBB stain have been used as a substrate and a detection procedure, respectively. Casein zymography has been using substrate concentration at 1 mg/mL and employing conventional CBB stain. Although ordinary casein zymography provides reproducible results, it has several disadvantages including time-consuming and relative low sensitivity. Improved casein zymography, RAMA casein zymography, is rapid and highly sensitive. RAMA casein zymography completes the detection process within 1 h after incubation and increases the sensitivity at least by tenfold. In addition to serine protease, the method also detects metalloprotease 7 (MMP7, Matrilysin) with high sensitivity.

  16. Highly sensitive determination of atropine using cobalt oxide nanostructures: Influence of functional groups on the signal sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Soomro, Razium Ali, E-mail: raziumsoomro@gmail.com [Interface Analysis Centre, School of Physics, University of Bristol, Bristol, BS8 1TL (United Kingdom); National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080 (Pakistan); Nafady, Ayman [Department of Chemistry, College of Science, King Saud University, Riyadh (Saudi Arabia); Department of Chemistry, Faculty of Science, Sohag University, Sohag (Egypt); Hallam, Keith Richard [Interface Analysis Centre, School of Physics, University of Bristol, Bristol, BS8 1TL (United Kingdom); Jawaid, Sana [National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080 (Pakistan); Al Enizi, Abdullah [Department of Chemistry, College of Science, King Saud University, Riyadh (Saudi Arabia); Sherazi, Syed Tufail Hussain; Sirajuddin [National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080 (Pakistan); Ibupoto, Zafar Hussain [Dr M.A. Kazi Institute of Chemistry, University of Sindh, Jamshoro, 76080 (Pakistan); Willander, Magnus [Department of Science and Technology, Campus Norrkoping, Linkoping University, SE-60174, Norrkoping (Sweden)

    2016-12-15

    This study describes sensitive determination of atropine using glassy carbon electrodes (GCE) modified with Co{sub 3}O{sub 4} nanostructures. The as-synthesised nanostructures were grown using cysteine (CYS), glutathione (GSH) and histidine (HYS) as effective templates under hydrothermal action. The obtained morphologies revealed interesting structural features, including both cavity-based and flower-shaped structures. The as-synthesised morphologies were noted to actively participate in electro-catalysis of atropine (AT) drug where GSH-assisted structures exhibited the best signal response in terms of current density and over-potential value. The study also discusses the influence of functional groups on the signal sensitivity of atropine electro-oxidation. The functionalisation was carried with the amino acids originally used as effective templates for the growth of Co{sub 3}O{sub 4} nanostructures. The highest increment was obtained when GSH was used as the surface functionalising agent. The GSH-functionalised Co{sub 3}O{sub 4}-modified electrode was utilised for the electro-chemical sensing of AT in a concentration range of 0.01–0.46 μM. The developed sensor exhibited excellent working linearity (R{sup 2} = 0.999) and signal sensitivity up to 0.001 μM of AT. The noted high sensitivity of the sensor is associated with the synergy of superb surface architectures and favourable interaction facilitating the electron transfer kinetics for the electro-catalytic oxidation of AT. Significantly, the developed sensor demonstrated excellent working capability when used for AT detection in human urine samples with strong anti-interference potential against common co-existing species, such as glucose, fructose, cysteine, uric acid, dopamine and ascorbic acid. - Highlights: • Template-assisted growth of Co{sub 3}O{sub 4} nanostructures. • Shape-dependent electro-catalysis of atropine. • Effect of functionalisation of signal sensitivity.

  17. High-speed asynchronous optical sampling for high-sensitivity detection of coherent phonons

    International Nuclear Information System (INIS)

    Dekorsy, T; Taubert, R; Hudert, F; Schrenk, G; Bartels, A; Cerna, R; Kotaidis, V; Plech, A; Koehler, K; Schmitz, J; Wagner, J

    2007-01-01

    A new optical pump-probe technique is implemented for the investigation of coherent acoustic phonon dynamics in the GHz to THz frequency range which is based on two asynchronously linked femtosecond lasers. Asynchronous optical sampling (ASOPS) provides the performance of on all-optical oscilloscope and allows us to record optically induced lattice dynamics over nanosecond times with femtosecond resolution at scan rates of 10 kHz without any moving part in the set-up. Within 1 minute of data acquisition time signal-to-noise ratios better than 10 7 are achieved. We present examples of the high-sensitivity detection of coherent phonons in superlattices and of the coherent acoustic vibration of metallic nanoparticles

  18. High-precision high-sensitivity clock recovery circuit for a mobile payment application

    International Nuclear Information System (INIS)

    Sun Lichong; Yan Na; Min Hao; Ren Wenliang

    2011-01-01

    This paper presents a fully integrated carrier clock recovery circuit for a mobile payment application. The architecture is based on a sampling-detection module and a charge pump phase locked loop. Compared with clock recovery in conventional 13.56 MHz transponders, this circuit can recover a high-precision consecutive carrier clock from the on/off keying (OOK) signal sent by interrogators. Fabricated by a SMIC 0.18-μm EEPROM CMOS process, this chip works from a single power supply as low as 1.5 V Measurement results show that this circuit provides 0.34% frequency deviation and 8 mV sensitivity. (semiconductor integrated circuits)

  19. A highly sensitive method for quantification of iohexol

    DEFF Research Database (Denmark)

    Schulz, A.; Boeringer, F.; Swifka, J.

    2014-01-01

    -chromatography-electrospray-massspectrometry (LC-ESI-MS) approach using the multiple reaction monitoring mode for iohexol quantification. In order to test whether a significantly decreased amount of iohexol is sufficient for reliable quantification, a LC-ESI-MS approach was assessed. We analyzed the kinetics of iohexol in rats after application...... of different amounts of iohexol (15 mg to 150 1.tg per rat). Blood sampling was conducted at four time points, at 15, 30, 60, and 90 min, after iohexol injection. The analyte (iohexol) and the internal standard (iotha(amic acid) were separated from serum proteins using a centrifugal filtration device...... with a cut-off of 3 kDa. The chromatographic separation was achieved on an analytical Zorbax SB C18 column. The detection and quantification were performed on a high capacity trap mass spectrometer using positive ion ESI in the multiple reaction monitoring (MRM) mode. Furthermore, using real-time polymerase...

  20. High Quality Rapeseed Products as Feed for Sensitive Monogastrics

    DEFF Research Database (Denmark)

    Frandsen, Heidi Blok

    in plants of the order Brassicales (former known as Capparales), which include rapeseed, rype (Brassica campestris L.) Indian mustard (Brassica juncea L.), broccoli (Brassica oleracea L.var. italica) and many other plants. Glucosinolates have been studied widely for their biologic effects ranging from...... by xenobiotica enzymes in the liver. The last study (manuscript IV) deals with the novel processing techniques, pulsed electric field (PEF) and high pressure treatment (HPT) and the processing effects on glucosinolates in broccoli. The largest effects were observed to be a result of the different handling...... of the plant materials prior to the process treatment. It was thus found that a great amount of the glucosinolate loss has occurred in the broccoli juice and purée prior to PEF processing. Only a minor loss was observed in broccoli flowers prior to processing, and HP treatment at 700 MPa for 10 min. was found...

  1. Silicon nanowire structures as high-sensitive pH-sensors

    International Nuclear Information System (INIS)

    Belostotskaya, S O; Chuyko, O V; Kuznetsov, A E; Kuznetsov, E V; Rybachek, E N

    2012-01-01

    Sensitive elements for pH-sensors created on silicon nanostructures were researched. Silicon nanostructures have been used as ion-sensitive field effect transistor (ISFET) for the measurement of solution pH. Silicon nanostructures have been fabricated by 'top-down' approach and have been studied as pH sensitive elements. Nanowires have the higher sensitivity. It was shown, that sensitive element, which is made of 'one-dimensional' silicon nanostructure have bigger pH-sensitivity as compared with 'two-dimensional' structure. Integrated element formed from two p- and n-type nanowire ISFET ('inverter') can be used as high sensitivity sensor for local relative change [H+] concentration in very small volume.

  2. A novel high resolution, high sensitivity SPECT detector for molecular imaging of cardiovascular diseases

    Science.gov (United States)

    Cusanno, F.; Argentieri, A.; Baiocchi, M.; Colilli, S.; Cisbani, E.; De Vincentis, G.; Fratoni, R.; Garibaldi, F.; Giuliani, F.; Gricia, M.; Lucentini, M.; Magliozzi, M. L.; Majewski, S.; Marano, G.; Musico, P.; Musumeci, M.; Santavenere, F.; Torrioli, S.; Tsui, B. M. W.; Vitelli, L.; Wang, Y.

    2010-05-01

    Cardiovascular diseases are the most common cause of death in western countries. Understanding the rupture of vulnerable atherosclerotic plaques and monitoring the effect of innovative therapies of heart failure is of fundamental importance. A flexible, high resolution, high sensitivity detector system for molecular imaging with radionuclides on small animal models has been designed for this aim. A prototype has been built using tungsten pinhole and LaBr3(Ce) scintillator coupled to Hamamatsu Flat Panel PMTs. Compact individual-channel readout has been designed, built and tested. Measurements with phantoms as well as pilot studies on mice have been performed, the results show that the myocardial perfusion in mice can be determined with sufficient precision. The detector will be improved replacing the Hamamatsu Flat Panel with Silicon Photomultipliers (SiPMs) to allow integration of the system with MRI scanners. Application of LaBr3(Ce) scintillator coupled to photosensor with high photon detection efficiency and excellent energy resolution will allow dual-label imaging to monitor simultaneously the cardiac perfusion and the molecular targets under investigation during the heart therapy.

  3. Nanowire-templated microelectrodes for high-sensitivity pH detection

    DEFF Research Database (Denmark)

    Antohe, V.A.; Radu, Adrian; Mátéfi-Tempfli, Mária

    2009-01-01

    A highly sensitive pH capacitive sensor has been designed by confined growth of vertically aligned nanowire arrays on interdigited microelectrodes. The active surface of the device has been functionalized with an electrochemical pH transducer (polyaniline). We easily tune the device features...... by combining lithographic techniques with electrochemical synthesis. The reported electrical LC resonance measurements show considerable sensitivity enhancement compared to conventional capacitive pH sensors realized with microfabricated interdigited electrodes. The sensitivity can be easily improved...

  4. Eating high-fat chow enhances sensitization to the effects of methamphetamine on locomotion in rats.

    Science.gov (United States)

    McGuire, Blaine A; Baladi, Michelle G; France, Charles P

    2011-05-11

    Eating high-fat chow can modify the effects of drugs acting directly or indirectly on dopamine systems and repeated intermittent drug administration can markedly increase sensitivity (i.e., sensitization) to the behavioral effects of indirect-acting dopamine receptor agonists (e.g., methamphetamine). This study examined whether eating high-fat chow alters the sensitivity of male Sprague Dawley rats to the locomotor stimulating effects of acute or repeated administration of methamphetamine. The acute effects of methamphetamine on locomotion were not different between rats (n=6/group) eating high-fat or standard chow for 1 or 4 weeks. Sensitivity to the effects of methamphetamine (0.1-10mg/kg, i.p.) increased progressively across 4 once per week tests; this sensitization developed more rapidly and to a greater extent in rats eating high-fat chow as compared with rats eating standard chow. Thus, while eating high-fat chow does not appear to alter sensitivity of rats to acutely-administered methamphetamine, it significantly increases the sensitization that develops to repeated intermittent administration of methamphetamine. These data suggest that eating certain foods influences the development of sensitization to drugs acting on dopamine systems. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. CONSTRUCTION OF A DIFFERENTIAL ISOTHERMAL CALORIMETER OF HIGH SENSITIVITY AND LOW COST.

    OpenAIRE

    Trinca, RB; Perles, CE; Volpe, PLO

    2009-01-01

    CONSTRUCTION OF A DIFFERENTIAL ISOTHERMAL CALORIMETER OF HIGH SENSITIVITY AND LOW COST The high cost of sensitivity commercial calorimeters may represent an obstacle for many calorimetric research groups. This work describes (fie construction and calibration of a batch differential heat conduction calorimeter with sample cells volumes of about 400 mu L. The calorimeter was built using two small high sensibility square Peltier thermoelectric sensors and the total cost was estimated to be about...

  6. Development of the "Highly Sensitive Dog" questionnaire to evaluate the personality dimension "Sensory Processing Sensitivity" in dogs.

    Directory of Open Access Journals (Sweden)

    Maya Braem

    Full Text Available In humans, the personality dimension 'sensory processing sensitivity (SPS', also referred to as "high sensitivity", involves deeper processing of sensory information, which can be associated with physiological and behavioral overarousal. However, it has not been studied up to now whether this dimension also exists in other species. SPS can influence how people perceive the environment and how this affects them, thus a similar dimension in animals would be highly relevant with respect to animal welfare. We therefore explored whether SPS translates to dogs, one of the primary model species in personality research. A 32-item questionnaire to assess the "highly sensitive dog score" (HSD-s was developed based on the "highly sensitive person" (HSP questionnaire. A large-scale, international online survey was conducted, including the HSD questionnaire, as well as questions on fearfulness, neuroticism, "demographic" (e.g. dog sex, age, weight; age at adoption, etc. and "human" factors (e.g. owner age, sex, profession, communication style, etc., and the HSP questionnaire. Data were analyzed using linear mixed effect models with forward stepwise selection to test prediction of HSD-s by the above-mentioned factors, with country of residence and dog breed treated as random effects. A total of 3647 questionnaires were fully completed. HSD-, fearfulness, neuroticism and HSP-scores showed good internal consistencies, and HSD-s only moderately correlated with fearfulness and neuroticism scores, paralleling previous findings in humans. Intra- (N = 447 and inter-rater (N = 120 reliabilities were good. Demographic and human factors, including HSP score, explained only a small amount of the variance of HSD-s. A PCA analysis identified three subtraits of SPS, comparable to human findings. Overall, the measured personality dimension in dogs showed good internal consistency, partial independence from fearfulness and neuroticism, and good intra- and inter

  7. Differential sensitivity of long-sleep and short-sleep mice to high doses of cocaine.

    Science.gov (United States)

    de Fiebre, C M; Ruth, J A; Collins, A C

    1989-12-01

    The cocaine sensitivity of male and female long-sleep (LS) and short-sleep (SS) mice, which have been selectively bred for differential ethanol-induced "sleep-time," was examined in a battery of behavioral and physiological tests. Differences between these two mouse lines were subtle and were seen primarily at high doses. At high doses, SS mice were more sensitive than LS mice, particularly to cocaine-induced hypothermia; however, significant hypothermia was not seen except at doses which were very near to the seizure threshold. During a 60-min test of locomotor activity, LS mice showed greater stimulation of Y-maze activity by 20 mg/kg cocaine than SS mice. Consistent with the finding of subtle differences in sensitivity to low doses of cocaine. LS and SS mice did not differ in sensitivity to cocaine inhibition of synaptosomal uptake of [3H]-dopamine, [3H]-norepinephrine or [3H]-5-hydroxytryptamine. However, consistent with the finding of differential sensitivity to high doses of cocaine, SS mice were more sensitive to the seizure-producing effects of the cocaine and lidocaine, a local anesthetic. It is hypothesized that the differential sensitivity of these mouse lines to high doses of cocaine is due to differential sensitivity to cocaine's actions on systems that regulate local anesthetic effects. Selective breeding for differential duration of alcohol-induced "sleep-time" may have resulted in differential ion channel structure or function in these mice.

  8. Organic dye for highly efficient solid-state dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt-Mende, L.; Bach, U.; Humphry-Baker, R.; Ito, S.; Graetzel, M. [Institut des Sciences et Ingenierie Chimiques (ISIC), Laboratoire de Photonique et Interfaces (LPI), Ecole Polytechnique Federale de Lausanne (EPFL), CH-1015 Lausanne (Switzerland); Horiuchi, T.; Miura, H. [Technology Research Laboratory, Corporate Research Center, Mitsubishi Paper Mills Limited, 46, Wadai, Tsukuba City, Ibaraki 300-4247 (Japan); Uchida, S. [Institute of Multidisciplinary Research for Advanced Materials (IMRAM), Tohoku University, 1-1 Katahira 2-chome, Aoba-ku, Sendai 980-8577 (Japan)

    2005-04-04

    The feasibility of solid-state dye-sensitized solar cells as a low-cost alternative to amorphous silicon cells is demonstrated. Such a cell with a record efficiency of over 4 % under simulated sunlight is reported, made possible by using a new organic metal-free indoline dye as the sensitizer with high absorption coefficient. (Abstract Copyright [2005], Wiley Periodicals, Inc.)

  9. Morphology-Controlled 9,10-Diphenylanthracene Nanoblocks as Electrochemiluminescence Emitters for MicroRNA Detection with One-Step DNA Walker Amplification.

    Science.gov (United States)

    Liu, Jia-Li; Tang, Zhi-Ling; Zhang, Jia-Qi; Chai, Ya-Qin; Zhuo, Ying; Yuan, Ruo

    2018-04-17

    The electrochemiluminescence (ECL) properties of polycyclic aromatic hydrocarbons (PAHs) are excellent on account of the high photoluminescence quantum yield. However, the poor solubility and radical instability of PAHs in the aqueous solution severely restricted further biological application. Here 9,10-diphenylanthracene (DPA) nanoblocks (NBs) with good dispersibility and stability in aqueous solution were prepared according to morphology-controlled technology employing water-soluble polymers as a protectant. Furthermore, an ECL "off-on" switch biosensor was developed based on a novel ECL ternary system with DPA NBs as luminophore, dissolved O 2 as coreactant, and Pt-Ag alloy nanoflowers as the coreaction accelerator, which achieved a high-intense initial ECL signal. Subsequently, the Fc-DNA as ECL signal quencher was assembled on the electrode surface to quench the initial ECL signal for a "signal-off" state. Meanwhile, DNA swing arm was modified on the electrode surface for one-step DNA walker amplification. Interestingly, in the presence of miRNA-141 and T7 Exo, the one-step DNA walker amplification was executed to recover a strong ECL signal as a "signal-on" state by the digestion of Fc-DNA. Thus the developed ECL "off-on" switch biosensor possesses a detection limit down to 29.5 aM for ultrasensitive detection of miRNA-141, which is expected to be applicable to the detection of miRNA in clinic tumor cells.

  10. RAMA casein zymography: Time-saving and highly sensitive casein zymography for MMP7 and trypsin.

    Science.gov (United States)

    Yasumitsu, Hidetaro; Ozeki, Yasuhiro; Kanaly, Robert A

    2016-11-01

    To detect metalloproteinase-7 (MMP7), zymography is conducted using a casein substrate and conventional CBB stain. It has disadvantages because it is time consuming and has low sensitivity. Previously, a sensitive method to detect MMP7 up to 30 pg was reported, however it required special substrates and complicated handlings. RAMA casein zymography described herein is rapid, sensitive, and reproducible. By applying high-sensitivity staining with low substrate conditions, the staining process is completed within 1 h and sensitivity was increased 100-fold. The method can detect 10 pg MMP7 by using commercially available casein without complicated handlings. Moreover, it increases detection sensitivity for trypsin. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Electrochemiluminescence and chemiluminescence of a carboxylic acid derivative of ruthenium(II) tris-(2,2'-bipyridine) chelate synthesized for labeling purposes

    International Nuclear Information System (INIS)

    Jiang Qinghong; Sun Shiguo; Hakansson, Markus; Langel, Kaarina; Ylinen, Tiina; Suomi, Johanna; Kulmala, Sakari

    2006-01-01

    Synthesis, purification and characterization of [4-ethoxycarbonyl-4'-carboxy-2,2'-bipyridine]bis(2,2'-bipyridine) ruthenium(II) hexafluorophosphate is described. This complex is shown to be electrochemiluminescent in aqueous solution during cathodic pulse polarization of thin insulating film-coated electrodes. Electrochemiluminescence (ECL) lifetime of the complex was observed to be ca. 40 μs at oxide-coated n-silicon electrodes; thus time-resolved detection is also possible. The ECL emission maximum of this carboxylate derivative is somewhat red-shifted when compared with an unmodified Ru(bpy) 3 2+ . Because the present complex can be easily covalently coupled with antibodies and oligonucleotides it is usable as an electrochemiluminescent label in various bioaffinity assays. The present chelates also produce strong chemiluminescence during dissolution of metallic magnesium in aqueous solution

  12. Analytical applications of the electrochemiluminescence of tris(2,2'-bipyridyl)ruthenium(II) coupled to capillary/microchip electrophoresis: A review

    International Nuclear Information System (INIS)

    Su Ming; Wei Wei; Liu Songqin

    2011-01-01

    Graphical abstract: The mechanism of Ru(bpy) 3 2+ electrochemiluminescence, addition mode of Ru(bpy) 3 2+ , recent applications of capillary electrophoresis coupled with electrochemiluminescent detection in drug and other substrates analysis are reviewed. - Abstract: A comprehensive review on the development of analytical methods, by coupling electrochemiluminescence (ECL) detection with capillary electrophoresis (CE) and microchip electrophoresis (ME), is presented. After the description of the basic mechanism of ECL, the addition mode of luminescence reagent in CE-ECL system has been discussed. The analytical applications of the CE-ECL technique in terms of different analytes are also given. Due to the importance of ME as a separation method for the present and future, the ME detection methods based on ECL are considered in a relatively detailed way. Finally, possible trends for CE/ME-ECL in the near future are discussed.

  13. Analytical applications of the electrochemiluminescence of tris(2,2'-bipyridyl)ruthenium(II) coupled to capillary/microchip electrophoresis: A review

    Energy Technology Data Exchange (ETDEWEB)

    Su Ming; Wei Wei [School of Chemistry and Chemical Engineering, Southeast University, Nanjing, 211189 (China); Liu Songqin, E-mail: liusq@seu.edu.cn [School of Chemistry and Chemical Engineering, Southeast University, Nanjing, 211189 (China)

    2011-10-17

    Graphical abstract: The mechanism of Ru(bpy){sub 3}{sup 2+} electrochemiluminescence, addition mode of Ru(bpy){sub 3}{sup 2+}, recent applications of capillary electrophoresis coupled with electrochemiluminescent detection in drug and other substrates analysis are reviewed. - Abstract: A comprehensive review on the development of analytical methods, by coupling electrochemiluminescence (ECL) detection with capillary electrophoresis (CE) and microchip electrophoresis (ME), is presented. After the description of the basic mechanism of ECL, the addition mode of luminescence reagent in CE-ECL system has been discussed. The analytical applications of the CE-ECL technique in terms of different analytes are also given. Due to the importance of ME as a separation method for the present and future, the ME detection methods based on ECL are considered in a relatively detailed way. Finally, possible trends for CE/ME-ECL in the near future are discussed.

  14. Prototype of high resolution PET using resistive electrode position sensitive CdTe detectors

    International Nuclear Information System (INIS)

    Kikuchi, Yohei; Ishii, Keizo; Matsuyama, Shigeo; Yamazaki, Hiromichi

    2008-01-01

    Downsizing detector elements makes it possible that spatial resolutions of positron emission tomography (PET) cameras are improved very much. From this point of view, semiconductor detectors are preferable. To obtain high resolution, the pixel type or the multi strip type of semiconductor detectors can be used. However, in this case, there is a low packing ratio problem, because a dead area between detector arrays cannot be neglected. Here, we propose the use of position sensitive semiconductor detectors with resistive electrode. The CdTe detector is promising as a detector for PET camera because of its high sensitivity. In this paper, we report development of prototype of high resolution PET using resistive electrode position sensitive CdTe detectors. We made 1-dimensional position sensitive CdTe detectors experimentally by changing the electrode thickness. We obtained 750 A as an appropriate thickness of position sensitive detectors, and evaluated the performance of the detector using a collimated 241 Am source. A good position resolution of 1.2 mm full width half maximum (FWHM) was obtained. On the basis of the fundamental development of resistive electrode position sensitive detectors, we constructed a prototype of high resolution PET which was a dual head type and was consisted of thirty-two 1-dimensional position sensitive detectors. In conclusion, we obtained high resolutions which are 0.75 mm (FWHM) in transaxial, and 1.5 mm (FWHM) in axial. (author)

  15. Highly sensitive optical chemosensor for the detection of Cu using a ...

    Indian Academy of Sciences (India)

    Administrator

    Highly sensitive colorimetric chemosensor molecule RHN for selective detection of Cu. 2+ in ... colour development against the colourless blank during the sensing event, a feature that would facilitate ... ever reported, much attention has been.

  16. A highly sensitive, low-cost, wearable pressure sensor based on conductive hydrogel spheres

    KAUST Repository

    Tai, Yanlong; Mulle, Matthieu; Ventura, Isaac Aguilar; Lubineau, Gilles

    2015-01-01

    Wearable pressure sensing solutions have promising future for practical applications in health monitoring and human/machine interfaces. Here, a highly sensitive, low-cost, wearable pressure sensor based on conductive single-walled carbon nanotube

  17. A new method of removing the high value feedback resistor in the charge sensitive preamplifier

    International Nuclear Information System (INIS)

    Xi Deming

    1993-01-01

    A new method of removing the high value feedback resistor in the charge sensitive preamplifier is introduced. The circuit analysis of this novel design is described and the measured performances of a practical circuit are provided

  18. Use of Monoclonal Antibodies in the Sensitive Detection and Neutralization of Botulinum Neurotoxin Serotype B

    Directory of Open Access Journals (Sweden)

    Luisa W. Cheng

    2015-11-01

    Full Text Available Botulinum neurotoxins (BoNT are some of nature’s most potent toxins. Due to potential food contamination, and bioterrorism concerns, the development of detection reagents, therapeutics and countermeasures are of urgent interest. Recently, we have developed a sensitive electrochemiluminescent (ECL immunoassay for BoNT/B, using monoclonal antibodies (mAbs MCS6-27 and anti-BoNT/B rabbit polyclonal antibodies as the capture and detector. The ECL assay detected as little as 1 pg/mL BoNT/B in the buffer matrix, surpassing the detection sensitivities of the gold standard mouse bioassays. The ECL assay also allowed detection of BoNT/B in sera matrices of up to 100% sera with negligible matrix effects. This highly-sensitive assay allowed the determination of the biological half-lives of BoNT/B holotoxin in vivo. We further tested the toxin neutralization potential of our monoclonal antibodies using the mouse systemic and oral intoxication models. A combination of mAbs protected mice in both pre- and post-exposure models to lethal doses of BoNT/B. MAbs were capable of increasing survival of animals when administered even 10 h post-intoxication in an oral model, suggesting a likely time for BoNT/B complexes to reach the blood stream. More sensitive detection assays and treatments against BoNT intoxication will greatly enhance efforts to combat botulism.

  19. High-Q Fabry–Pérot Micro-Cavities for High-Sensitivity Volume Refractometry

    Directory of Open Access Journals (Sweden)

    Noha Gaber

    2018-01-01

    Full Text Available This work reports a novel structure for a Fabry–Pérot micro cavity that combines the highest reported quality factor for an on-chip Fabry–Pérot resonator that exceeds 9800, and a very high sensitivity for an on-chip volume refractometer based on a Fabry–Pérot cavity that is about 1000 nm/refractive index unit (RIU. The structure consists of two cylindrical Bragg micromirrors that achieve confinement of the Gaussian beam in the plan parallel to the chip substrate, while for the perpendicular plan, external fiber rod lenses (FRLs are placed in the optical path of the input and the output of the cavity. This novel structure overcomes number of the drawbacks presented in previous designs. The analyte is passed between the mirrors, enabling its detection from the resonance peak wavelengths of the transmission spectra. Mixtures of ethanol and deionized (DI-water with different ratios are used as analytes with different refractive indices to exploit the device as a micro-opto-fluidic refractometer. The design criteria are detailed and the modeling is based on Gaussian-optics equations, which depicts a scenario closer to reality than the usually used ray-optics modeling.

  20. High-throughput, Highly Sensitive Analyses of Bacterial Morphogenesis Using Ultra Performance Liquid Chromatography*

    Science.gov (United States)

    Desmarais, Samantha M.; Tropini, Carolina; Miguel, Amanda; Cava, Felipe; Monds, Russell D.; de Pedro, Miguel A.; Huang, Kerwyn Casey

    2015-01-01

    The bacterial cell wall is a network of glycan strands cross-linked by short peptides (peptidoglycan); it is responsible for the mechanical integrity of the cell and shape determination. Liquid chromatography can be used to measure the abundance of the muropeptide subunits composing the cell wall. Characteristics such as the degree of cross-linking and average glycan strand length are known to vary across species. However, a systematic comparison among strains of a given species has yet to be undertaken, making it difficult to assess the origins of variability in peptidoglycan composition. We present a protocol for muropeptide analysis using ultra performance liquid chromatography (UPLC) and demonstrate that UPLC achieves resolution comparable with that of HPLC while requiring orders of magnitude less injection volume and a fraction of the elution time. We also developed a software platform to automate the identification and quantification of chromatographic peaks, which we demonstrate has improved accuracy relative to other software. This combined experimental and computational methodology revealed that peptidoglycan composition was approximately maintained across strains from three Gram-negative species despite taxonomical and morphological differences. Peptidoglycan composition and density were maintained after we systematically altered cell size in Escherichia coli using the antibiotic A22, indicating that cell shape is largely decoupled from the biochemistry of peptidoglycan synthesis. High-throughput, sensitive UPLC combined with our automated software for chromatographic analysis will accelerate the discovery of peptidoglycan composition and the molecular mechanisms of cell wall structure determination. PMID:26468288

  1. Determination of malachite green in fish based on magnetic molecularly imprinted polymer extraction followed by electrochemiluminescence.

    Science.gov (United States)

    Huang, Baomei; Zhou, Xibin; Chen, Jing; Wu, Guofan; Lu, Xiaoquan

    2015-09-01

    A novel procedure for selective extraction of malachite green (MG) from fish samples was set up by using magnetic molecularly imprinted polymers (MMIP) as the solid phase extraction material followed by electrochemiluminescence (ECL) determination. MMIP was prepared by using Fe3O4 magnetite as magnetic component, MG as template molecule, methacrylic acid (MAA) as functional monomer and ethylene glycol dimethacrylate (EGDMA) as crosslinking agent. MMIP was characterized by SEM, TEM, FT-IR, VSM and XRD. Leucomalachite green (LMG) was oxidized in situ to MG by 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ). And then MMIP was successfully used to selectively enrich MG from fish samples. Adsorbed MG was desorbed and determined by ECL. Under the optimal conditions, calibration curve was good linear in the range of 0.29-290 μg/kg and the limit of detection (LOD) was 7.3 ng/kg (S/N=3). The recoveries of MMIP extraction were 77.1-101.2%. In addition, MMIP could be regenerated. To the best of our knowledge, MMIP coupling with ECL quenching of Ru(bpy)3(2+)/TPA for the determination of MG has not yet been developed. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Electrochemiluminescence of fluorescein in alkaline solution at a polycrystalline gold electrode

    International Nuclear Information System (INIS)

    Shi Mingjuan; Cui Hua

    2007-01-01

    The electrochemiluminescence (ECL) behavior of fluorescein at a polycrystalline gold electrode was studied under conventional cyclic voltammetric conditions. Five ECL peaks were observed at 0.94 (ECL-1), 1.51 (ECL-2), 1.34 (ECL-3), -0.06 (ECL-4), -0.73 to -1.11 V (ECL-5, a broad weak wave) (vs. SCE), respectively, on the curve of ECL intensity versus potential. These ECL peaks were found to depend on the pH of the solution, supporting electrolyte, potential scan ranges and directions. The emitter of ECL peaks was identified as fluorescein or eosin Y produced on the electrode by analyzing the ECL spectra and fluorescence spectra. The mechanisms for ECL peaks have been proposed due to the reactions of fluorescein and the electro-oxidation product of fluorescein with various oxygen-containing species in the solution or electrogenerated at different applied potentials such as O 2 , O 2 .- , HO 2 - , and BrO - . Singlet molecular oxygen was generated during the reactions and transferred its energy to the ECL emitter such as fluorescein or eosin Y, emitting light

  3. Enzymatic logic calculation systems based on solid-state electrochemiluminescence and molecularly imprinted polymer film electrodes.

    Science.gov (United States)

    Lian, Wenjing; Liang, Jiying; Shen, Li; Jin, Yue; Liu, Hongyun

    2018-02-15

    The molecularly imprinted polymer (MIP) films were electropolymerized on the surface of Au electrodes with luminol and pyrrole (PY) as the two monomers and ampicillin (AM) as the template molecule. The electrochemiluminescence (ECL) intensity peak of polyluminol (PL) of the AM-free MIP films at 0.7V vs Ag/AgCl could be greatly enhanced by AM rebinding. In addition, the ECL signals of the MIP films could also be enhanced by the addition of glucose oxidase (GOD)/glucose and/or ferrocenedicarboxylic acid (Fc(COOH) 2 ) in the testing solution. Moreover, Fc(COOH) 2 exhibited cyclic voltammetric (CV) response at the AM-free MIP film electrodes. Based on these results, a binary 3-input/6-output biomolecular logic gate system was established with AM, GOD and Fc(COOH) 2 as inputs and the ECL responses at different levels and CV signal as outputs. Some functional non-Boolean logic devices such as an encoder, a decoder and a demultiplexer were also constructed on the same platform. Particularly, on the basis of the same system, a ternary AND logic gate was established. The present work combined MIP film electrodes, the solid-state ECL, and the enzymatic reaction together, and various types of biomolecular logic circuits and devices were developed, which opened a novel avenue to construct more complicated bio-logic gate systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Determination of cocaine on banknotes through an aptamer-based electrochemiluminescence biosensor.

    Science.gov (United States)

    Cai, Qihong; Chen, Lifen; Luo, Fang; Qiu, Bin; Lin, Zhenyu; Chen, Guonan

    2011-04-01

    A novel electrochemiluminescence (ECL) "sandwich" biosensor has been developed to detect cocaine. The sandwich biosensor was fabricated on the basis of the fact that a single aptamer could be split into two fragments and the two dissociated parts could form a folded, associated complex in the presence of targets. One of these (capture probe), which had hexane-thiol at its 5'-terminus, was immobilized on a gold electrode via thiol-gold binding. The other one (detection probe) was labeled with the ECL reagent tris(2,2'-bipyridyl)ruthenium(II)-doped silica nanoparticles (RuSiNPs) at its 3'-terminus. Owing to the weak interaction between the two fragments, the sensor exhibited a low ECL signal in the absence of cocaine. After the target cocaine had been added to the solution, it induced association of the two fragments and stabilized the associated complexes, leading to immobilization of RuSiNPs on the electrode surface, and the ECL detected on the electrode surface was enhanced. The enhanced ECL intensity was directly proportional to the logarithm of the cocaine concentration in the range from 1.0 × 10(-9) to 1.0 × 10(-11) mol/L, with a detection limit of 3.7 × 10(-12) mol/L. The biosensor was applied to detect trace amounts of cocaine on banknotes with satisfactory results.

  5. Monochromatic and electrochemically switchable electrochemiluminescence of perovskite CsPbBr3 nanocrystals.

    Science.gov (United States)

    Huang, Yan; Fang, Mingxiang; Zou, Guizheng; Zhang, Bin; Wang, Huaisheng

    2016-11-10

    Cubic-shaped perovskite CsPbBr 3 nanocrystals (NCs) could be electrochemically injected with holes (or electrons) to produce several charged states under different oxidizing and reducing potentials, and then bring out electrochemiluminescence (ECL) of higher color purity than traditional ECL chemicals and metal chalcogenide NCs, in both annihilation and co-reactant routes. The difference of electrochemical gaps between varied hole and electron injecting potentials displayed little effect on the ECL spectrum and colour purity of CsPbBr 3 NCs. All the excited states generated under different oxidizing and reducing potential couples in ECL of CsPbBr 3 NCs were the same as those in photoluminescence, as all the ECL spectra were almost identical to the CsPbBr 3 NCs' photoluminescence spectrum. Importantly, the ECL of CsPbBr 3 NCs was electrochemically switchable and displayed an obvious "on/off" type feature by changing the sequence of hole injecting and electron injecting processes, as strong ECL could be obtained by injecting holes onto the electron injected NCs, while no or very weak ECL was obtained in the reversed way.

  6. Highly sensitive and selective detection of dopamine using one-pot synthesized highly photoluminescent silicon nanoparticles.

    Science.gov (United States)

    Zhang, Xiaodong; Chen, Xiaokai; Kai, Siqi; Wang, Hong-Yin; Yang, Jingjing; Wu, Fu-Gen; Chen, Zhan

    2015-03-17

    A simple and highly efficient method for dopamine (DA) detection using water-soluble silicon nanoparticles (SiNPs) was reported. The SiNPs with a high quantum yield of 23.6% were synthesized by using a one-pot microwave-assisted method. The fluorescence quenching capability of a variety of molecules on the synthesized SiNPs has been tested; only DA molecules were found to be able to quench the fluorescence of these SiNPs effectively. Therefore, such a quenching effect can be used to selectively detect DA. All other molecules tested have little interference with the dopamine detection, including ascorbic acid, which commonly exists in cells and can possibly affect the dopamine detection. The ratio of the fluorescence intensity difference between the quenched and unquenched cases versus the fluorescence intensity without quenching (ΔI/I) was observed to be linearly proportional to the DA analyte concentration in the range from 0.005 to 10.0 μM, with a detection limit of 0.3 nM (S/N = 3). To the best of our knowledge, this is the lowest limit for DA detection reported so far. The mechanism of fluorescence quenching is attributed to the energy transfer from the SiNPs to the oxidized dopamine molecules through Förster resonance energy transfer. The reported method of SiNP synthesis is very simple and cheap, making the above sensitive and selective DA detection approach using SiNPs practical for many applications.

  7. Depleted Nanocrystal-Oxide Heterojunctions for High-Sensitivity Infrared Detection

    Science.gov (United States)

    2015-08-28

    Approved for Public Release; Distribution Unlimited Final Report: 4.3 Electronic Sensing - Depleted Nanocrystal- Oxide Heterojunctions for High...reviewed journals: Final Report: 4.3 Electronic Sensing - Depleted Nanocrystal- Oxide Heterojunctions for High-Sensitivity Infrared Detection Report Title...PERCENT_SUPPORTEDNAME FTE Equivalent: Total Number: 1 1 Final Progress Report Project title: Depleted Nanocrystal- Oxide Heterojunctions for High

  8. Monte carlo calculation of energy-dependent response of high-sensitive neutron monitor, HISENS

    International Nuclear Information System (INIS)

    Imanaka, Tetsuji; Ebisawa, Tohru; Kobayashi, Keiji; Koide, Hiroaki; Seo, Takeshi; Kawano, Shinji

    1988-01-01

    A highly sensitive neutron monitor system, HISENS, has been developed to measure leakage neutrons from nuclear facilities. The counter system of HISENS contains a detector bank which consists of ten cylindrical proportional counters filled with 10 atm 3 He gas and a paraffin moderator mounted in an aluminum case. The size of the detector bank is 56 cm high, 66 cm wide and 10 cm thick. It is revealed by a calibration experiment using an 241 Am-Be neutron source that the sensitivity of HISENS is about 2000 times as large as that of a typical commercial rem-counter. Since HISENS is designed to have a high sensitivity in a wide range of neutron energy, the shape of its energy dependent response curve cannot be matched to that of the dose equivalent conversion factor. To estimate dose equivalent values from neutron counts by HISENS, it is necessary to know the energy and angular characteristics of both HISENS and the neutron field. The area of one side of the detector bank is 3700 cm 2 and the detection efficiency in the constant region of the response curve is about 30 %. Thus, the sensitivity of HISENS for this energy range is 740 cps/(n/cm 2 /sec). This value indicates the extremely high sensitivity of HISENS as compared with exsisting highly sensitive neutron monitors. (Nogami, K.)

  9. A novel detection platform for parallel monitoring of DNA hybridization with high sensitivity and specificity

    DEFF Research Database (Denmark)

    Yi, Sun; Perch-Nielsen, Ivan R.; Wang, Zhenyu

    We developed a high-sensitive platform to monior multiple hybridization events in real time. By creating a microoptical array in a polymeric chip, the system combine the excellent discriminative power of supercritical angle fluorescence (SAF) microscopy with high-throughput capabilities of microa......We developed a high-sensitive platform to monior multiple hybridization events in real time. By creating a microoptical array in a polymeric chip, the system combine the excellent discriminative power of supercritical angle fluorescence (SAF) microscopy with high-throughput capabilities...

  10. Do Electrochemiluminescence Assays Improve Prediction of Time to Type 1 Diabetes in Autoantibody-Positive TrialNet Subjects?

    OpenAIRE

    Fouts, Alexandra; Pyle, Laura; Yu, Liping; Miao, Dongmei; Michels, Aaron; Krischer, Jeffrey; Sosenko, Jay; Gottlieb, Peter; Steck, Andrea K.

    2016-01-01

    OBJECTIVE To explore whether electrochemiluminescence (ECL) assays can help improve prediction of time to type 1 diabetes in the TrialNet autoantibody-positive population. RESEARCH DESIGN AND METHODS TrialNet subjects who were positive for one or more autoantibodies (microinsulin autoantibody, GAD65 autoantibody [GADA], IA-2A, and ZnT8A) with available ECL-insulin autoantibody (IAA) and ECL-GADA data at their initial visit were analyzed; after a median follow-up of 24 months, 177 of these 1,2...

  11. ZnO nanorod biosensor for highly sensitive detection of specific protein binding

    International Nuclear Information System (INIS)

    Kim, Jin Suk; Park, Won Il; Lee, Chul Ho; Yi, Gyu Chul

    2006-01-01

    We report on the fabrication of electrical biosensors based on functionalized ZnO nanorod surfaces with biotin for highly sensitive detection of biological molecules. Due to the clean interface and easy surface modification, the ZnO nanorod sensors can easily detect streptavidin binding down to a concentration of 25 nM, which is more sensitive than previously reported one-dimensional (1D) nanostructure electrical biosensors. In addition, the unique device structure with a micrometer-scale hole at the center of the ZnO nanorod's conducting channel reduces the leakage current from the aqueous solution, hence enhancing device sensitivity. Moreover, ZnO nanorod field-effect-transistor (FET) sensors may open up opportunities to create many other oxide nanorod electrical sensors for highly sensitive and selective real-time detection of a wide variety of biomolecules.

  12. Highly Sensitive, Transparent, and Durable Pressure Sensors Based on Sea-Urchin Shaped Metal Nanoparticles.

    Science.gov (United States)

    Lee, Donghwa; Lee, Hyungjin; Jeong, Youngjun; Ahn, Yumi; Nam, Geonik; Lee, Youngu

    2016-11-01

    Highly sensitive, transparent, and durable pressure sensors are fabricated using sea-urchin-shaped metal nanoparticles and insulating polyurethane elastomer. The pressure sensors exhibit outstanding sensitivity (2.46 kPa -1 ), superior optical transmittance (84.8% at 550 nm), fast response/relaxation time (30 ms), and excellent operational durability. In addition, the pressure sensors successfully detect minute movements of human muscles. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. A high sensitivity process variation sensor utilizing sub-threshold operation

    OpenAIRE

    Meterelliyoz, Mesut; Song, Peilin; Stellari, Franco; Kulkarni, Jaydeep P.; Roy, Kaushik

    2008-01-01

    In this paper, we propose a novel low-power, bias-free, high-sensitivity process variation sensor for monitoring random variations in the threshold voltage. The proposed sensor design utilizes the exponential current-voltage relationship of sub-threshold operation thereby improving the sensitivity by 2.3X compared to the above-threshold operation. A test-chip containing 128 PMOS and 128 NMOS devices has been fabri...

  14. A Microneedle Functionalized with Polyethyleneimine and Nanotubes for Highly Sensitive, Label-Free Quantification of DNA

    OpenAIRE

    Saadat-Moghaddam, Darius; Kim, Jong-Hoon

    2017-01-01

    The accurate measure of DNA concentration is necessary for many DNA-based biological applications. However, the current methods are limited in terms of sensitivity, reproducibility, human error, and contamination. Here, we present a microneedle functionalized with polyethyleneimine (PEI) and single-walled carbon nanotubes (SWCNTs) for the highly sensitive quantification of DNA. The microneedle was fabricated using ultraviolet (UV) lithography and anisotropic etching, and then functionalized w...

  15. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili, E-mail: wangnsrl@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029 (China); Zhang, Kai [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Zhu, Peiping; Wu, Ziyu, E-mail: wuzy@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China and Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2015-02-15

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.

  16. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili; Zhang, Kai; Zhu, Peiping; Wu, Ziyu

    2015-01-01

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations

  17. Development of a high sensitivity pinhole type gamma camera using semiconductors for low dose rate fields

    Science.gov (United States)

    Ueno, Yuichiro; Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi; Fujishima, Yasutake; Yoshida, Akira; Umegaki, Kikuo

    2018-06-01

    We developed a pinhole type gamma camera, using a compact detector module of a pixelated CdTe semiconductor, which has suitable sensitivity and quantitative accuracy for low dose rate fields. In order to improve the sensitivity of the pinhole type semiconductor gamma camera, we adopted three methods: a signal processing method to set the discriminating level lower, a high sensitivity pinhole collimator and a smoothing image filter that improves the efficiency of the source identification. We tested basic performances of the developed gamma camera and carefully examined effects of the three methods. From the sensitivity test, we found that the effective sensitivity was about 21 times higher than that of the gamma camera for high dose rate fields which we had previously developed. We confirmed that the gamma camera had sufficient sensitivity and high quantitative accuracy; for example, a weak hot spot (0.9 μSv/h) around a tree root could be detected within 45 min in a low dose rate field test, and errors of measured dose rates with point sources were less than 7% in a dose rate accuracy test.

  18. High frequency electrical stimulation concurrently induces central sensitization and ipsilateral inhibitory pain modulation.

    Science.gov (United States)

    Vo, L; Drummond, P D

    2013-03-01

    In healthy humans, analgesia to blunt pressure develops in the ipsilateral forehead during various forms of limb pain. The aim of the current study was to determine whether this analgesic response is induced by ultraviolet B radiation (UVB), which evokes signs of peripheral sensitization, or by high-frequency electrical stimulation (HFS), which triggers signs of central sensitization. Before and after HFS and UVB conditioning, sensitivity to heat and to blunt and sharp stimuli was assessed at and adjacent to the treated site in the forearm. In addition, sensitivity to blunt pressure was measured bilaterally in the forehead. The effect of ipsilateral versus contralateral temple cooling on electrically evoked pain in the forearm was then examined, to determine whether HFS or UVB conditioning altered inhibitory pain modulation. UVB conditioning triggered signs of peripheral sensitization, whereas HFS conditioning triggered signs of central sensitization. Importantly, ipsilateral forehead analgesia developed after HFS but not UVB conditioning. In addition, decreases in electrically evoked pain at the HFS-treated site were greater during ipsilateral than contralateral temple cooling, whereas decreases at the UVB-treated site were similar during both procedures. HFS conditioning induced signs of central sensitization in the forearm and analgesia both in the ipsilateral forehead and the HFS-treated site. This ipsilateral analgesia was not due to peripheral sensitization or other non-specific effects, as it failed to develop after UVB conditioning. Thus, the supra-spinal mechanisms that evoke central sensitization might also trigger a hemilateral inhibitory pain modulation process. This inhibitory process could sharpen the boundaries of central sensitization or limit its spread. © 2012 European Federation of International Association for the Study of Pain Chapters.

  19. Epidermis Microstructure Inspired Graphene Pressure Sensor with Random Distributed Spinosum for High Sensitivity and Large Linearity.

    Science.gov (United States)

    Pang, Yu; Zhang, Kunning; Yang, Zhen; Jiang, Song; Ju, Zhenyi; Li, Yuxing; Wang, Xuefeng; Wang, Danyang; Jian, Muqiang; Zhang, Yingying; Liang, Renrong; Tian, He; Yang, Yi; Ren, Tian-Ling

    2018-03-27

    Recently, wearable pressure sensors have attracted tremendous attention because of their potential applications in monitoring physiological signals for human healthcare. Sensitivity and linearity are the two most essential parameters for pressure sensors. Although various designed micro/nanostructure morphologies have been introduced, the trade-off between sensitivity and linearity has not been well balanced. Human skin, which contains force receptors in a reticular layer, has a high sensitivity even for large external stimuli. Herein, inspired by the skin epidermis with high-performance force sensing, we have proposed a special surface morphology with spinosum microstructure of random distribution via the combination of an abrasive paper template and reduced graphene oxide. The sensitivity of the graphene pressure sensor with random distribution spinosum (RDS) microstructure is as high as 25.1 kPa -1 in a wide linearity range of 0-2.6 kPa. Our pressure sensor exhibits superior comprehensive properties compared with previous surface-modified pressure sensors. According to simulation and mechanism analyses, the spinosum microstructure and random distribution contribute to the high sensitivity and large linearity range, respectively. In addition, the pressure sensor shows promising potential in detecting human physiological signals, such as heartbeat, respiration, phonation, and human motions of a pushup, arm bending, and walking. The wearable pressure sensor array was further used to detect gait states of supination, neutral, and pronation. The RDS microstructure provides an alternative strategy to improve the performance of pressure sensors and extend their potential applications in monitoring human activities.

  20. High degree gravitational sensitivity from Mars orbiters for the GMM-1 gravity model

    Science.gov (United States)

    Lerch, F. J.; Smith, D. E.; Chan, J. C.; Patel, G. B.; Chinn, D. S.

    1994-01-01

    Orbital sensitivity of the gravity field for high degree terms (greater than 30) is analyzed on satellites employed in a Goddard Mars Model GMM-1, complete in spherical harmonics through degree and order 50. The model is obtained from S-band Doppler data on Mariner 9 (M9), Viking Orbiter 1 (VO1), and Viking Orbiter 2 (VO2) spacecraft, which were tracked by the NASA Deep Space Network on seven different highly eccentric orbits. The main sensitivity of the high degree terms is obtained from the VO1 and VO2 low orbits (300 km periapsis altitude), where significant spectral sensitivity is seen for all degrees out through degree 50. The velocity perturbations show a dominant effect at periapsis and significant effects out beyond the semi-latus rectum covering over 180 degrees of the orbital groundtrack for the low altitude orbits. Because of the wideband of periapsis motion covering nearly 180 degrees in w and +39 degrees in latitude coverage, the VO1 300 km periapsis altitude orbit with inclination of 39 degrees gave the dominant sensitivity in the GMM-1 solution for the high degree terms. Although the VO2 low periapsis orbit has a smaller band of periapsis mapping coverage, it strongly complements the VO1 orbit sensitivity for the GMM-1 solution with Doppler tracking coverage over a different inclination of 80 degrees.

  1. Flexible hemispheric microarrays of highly pressure-sensitive sensors based on breath figure method.

    Science.gov (United States)

    Wang, Zhihui; Zhang, Ling; Liu, Jin; Jiang, Hao; Li, Chunzhong

    2018-05-30

    Recently, flexible pressure sensors featuring high sensitivity, broad sensing range and real-time detection have aroused great attention owing to their crucial role in the development of artificial intelligent devices and healthcare systems. Herein, highly sensitive pressure sensors based on hemisphere-microarray flexible substrates are fabricated via inversely templating honeycomb structures deriving from a facile and static breath figure process. The interlocked and subtle microstructures greatly improve the sensing characteristics and compressibility of the as-prepared pressure sensor, endowing it a sensitivity as high as 196 kPa-1 and a wide pressure sensing range (0-100 kPa), as well as other superior performance, including a lower detection limit of 0.5 Pa, fast response time (10 000 cycles). Based on the outstanding sensing performance, the potential capability of our pressure sensor in capturing physiological information and recognizing speech signals has been demonstrated, indicating promising application in wearable and intelligent electronics.

  2. Photon Counting System for High-Sensitivity Detection of Bioluminescence at Optical Fiber End.

    Science.gov (United States)

    Iinuma, Masataka; Kadoya, Yutaka; Kuroda, Akio

    2016-01-01

    The technique of photon counting is widely used for various fields and also applicable to a high-sensitivity detection of luminescence. Thanks to recent development of single photon detectors with avalanche photodiodes (APDs), the photon counting system with an optical fiber has become powerful for a detection of bioluminescence at an optical fiber end, because it allows us to fully use the merits of compactness, simple operation, highly quantum efficiency of the APD detectors. This optical fiber-based system also has a possibility of improving the sensitivity to a local detection of Adenosine triphosphate (ATP) by high-sensitivity detection of the bioluminescence. In this chapter, we are introducing a basic concept of the optical fiber-based system and explaining how to construct and use this system.

  3. A Flexible and Highly Sensitive Piezoresistive Pressure Sensor Based on Micropatterned Films Coated with Carbon Nanotubes

    Directory of Open Access Journals (Sweden)

    Jia-lin Yao

    2016-01-01

    Full Text Available Excellent flexibility, high sensitivity, and low consumption are essential characteristics in flexible microtube pressure sensing occasion, for example, implantable medical devices, industrial pipeline, and microfluidic chip. This paper reports a flexible, highly sensitive, and ultrathin piezoresistive pressure sensor for fluid pressure sensing, whose sensing element is micropatterned films with conductive carbon nanotube layer. The flexible pressure sensor, the thickness of which is 40 ± 10 μm, could be economically fabricated by using biocompatible polydimethylsiloxane (PDMS. Experimental results show that the flexible pressure sensor has high sensitivity (0.047 kPa−1 in gas sensing and 5.6 × 10−3 kPa−1 in liquid sensing and low consumption (<180 μW, and the sensor could be used to measure the pressure in curved microtubes.

  4. Multimode fiber tip Fabry-Perot cavity for highly sensitive pressure measurement.

    Science.gov (United States)

    Chen, W P; Wang, D N; Xu, Ben; Zhao, C L; Chen, H F

    2017-03-23

    We demonstrate an optical Fabry-Perot interferometer fiber tip sensor based on an etched end of multimode fiber filled with ultraviolet adhesive. The fiber device is miniature (with diameter of less than 60 μm), robust and low cost, in a convenient reflection mode of operation, and has a very high gas pressure sensitivity of -40.94 nm/MPa, a large temperature sensitivity of 213 pm/°C within the range from 55 to 85 °C, and a relatively low temperature cross-sensitivity of 5.2 kPa/°C. This device has a high potential in monitoring environment of high pressure.

  5. A highly sensitive CMOS digital Hall sensor for low magnetic field applications.

    Science.gov (United States)

    Xu, Yue; Pan, Hong-Bin; He, Shu-Zhuan; Li, Li

    2012-01-01

    Integrated CMOS Hall sensors have been widely used to measure magnetic fields. However, they are difficult to work with in a low magnetic field environment due to their low sensitivity and large offset. This paper describes a highly sensitive digital Hall sensor fabricated in 0.18 μm high voltage CMOS technology for low field applications. The sensor consists of a switched cross-shaped Hall plate and a novel signal conditioner. It effectively eliminates offset and low frequency 1/f noise by applying a dynamic quadrature offset cancellation technique. The measured results show the optimal Hall plate achieves a high current related sensitivity of about 310 V/AT. The whole sensor has a remarkable ability to measure a minimum ± 2 mT magnetic field and output a digital Hall signal in a wide temperature range from -40 °C to 120 °C.

  6. Chip-based generation of carbon nanodots via electrochemical oxidation of screen printed carbon electrodes and the applications for efficient cell imaging and electrochemiluminescence enhancement.

    Science.gov (United States)

    Xu, Yuanhong; Liu, Jingquan; Zhang, Jizhen; Zong, Xidan; Jia, Xiaofang; Li, Dan; Wang, Erkang

    2015-06-07

    A portable lab-on-a-chip methodology to generate ionic liquid-functionalized carbon nanodots (CNDs) was developed via electrochemical oxidation of screen printed carbon electrodes. The CNDs can be successfully applied for efficient cell imaging and solid-state electrochemiluminescence sensor fabrication on the paper-based chips.

  7. Electrochemiluminescence resonance energy transfer system between GNRs and Ru(bpy)32+: Application in magnetic aptasensor for β-amyloid.

    Science.gov (United States)

    Ke, Hong; Sha, Haifeng; Wang, Yinfang; Guo, Weiwei; Zhang, Xin; Wang, Zhiming; Huang, Chusen; Jia, Nengqin

    2018-02-15

    Electrochemiluminescent (ECL) assay has gradually drawn increasing interest in the biomedical analysis. This paper proposed a new methodology for ultrasensitive and facile detection of Alzheimer's disease marker β-amyloid (Aβ) by fabricating a sandwich-type ECL sensing platform. Herein, electrochemiluminescence resonance energy transfer (ECL-RET) was employed to determine Aβ concentration, which can be attributed to the quenching effect from RET between Ru(bpy) 3 2+ and gold nanorods (GNRs) acting as ECL-RET electron donor and acceptor, respectively. In this protocol, mesoporous carbon nanospheres were adopted to immobilize ECL reactant Ru(bpy) 3 2+ and antibody via nafion to acquire the RET donor nanocomposites (MOCs/nafion/Ru(bpy) 3 2+ /antibody), which were tightly interconnected with epoxy group functionalized Fe 3 O 4 nanoparticles. It is of vital importance that GNRs with exquisite rod shape were synthesized and exhibited a typical absorption peak at 650nm to quench ECL signal of Ru(bpy) 3 2+ effectively. In addition, the ECL emission decreased linearly with the logarithm of Aβ concentration in a wide linear range from 1.0 × 10 -5 to 100ng/mL with a detection limit of 4.2 × 10 -6 ng/mL. Furthermore, distinctive and desirable properties were verified to declare the promise for being applicable to analyze the Aβ content in real Alzheimer's cerebrospinal fluid samples with satisfactory results. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Real-time, single-step bioassay using nanoplasmonic resonator with ultra-high sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiang; Ellman, Jonathan A; Chen, Fanqing Frank; Su, Kai-Hang; Wei, Qi-Huo; Sun, Cheng

    2014-04-01

    A nanoplasmonic resonator (NPR) comprising a metallic nanodisk with alternating shielding layer(s), having a tagged biomolecule conjugated or tethered to the surface of the nanoplasmonic resonator for highly sensitive measurement of enzymatic activity. NPRs enhance Raman signals in a highly reproducible manner, enabling fast detection of protease and enzyme activity, such as Prostate Specific Antigen (paPSA), in real-time, at picomolar sensitivity levels. Experiments on extracellular fluid (ECF) from paPSA-positive cells demonstrate specific detection in a complex bio-fluid background in real-time single-step detection in very small sample volumes.

  9. High sensitivity, high surface area Enzyme-linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Singh, Harpal; Morita, Takahiro; Suzuki, Yuma; Shimojima, Masayuki; Le Van, An; Sugamata, Masami; Yang, Ming

    2015-01-01

    Enzyme-linked immunosorbent assays (ELISA) are considered the gold standard in the demonstration of various immunological reactions with an application in the detection of infectious diseases such as during outbreaks or in patient care. This study aimed to produce an ELISA-based diagnostic with an increased sensitivity of detection compared to the standard 96-well method in the immunologic diagnosis of infectious diseases. A '3DStack' was developed using readily available, low cost fabrication technologies namely nanoimprinting and press stamping with an increased surface area of 4 to 6 times more compared to 96-well plates. This was achieved by stacking multiple nanoimprinted polymer sheets. The flow of analytes between the sheets was enhanced by rotating the 3DStack and confirmed by Finite-Element (FE) simulation. An Immunoglobulin G (IgG) ELISA for the detection of antibodies in human serum raised against Rubella virus was performed for validation. An improved sensitivity of up to 1.9 folds higher was observed using the 3DStack compared to the standard method. The increased surface area of the 3DStack developed using nanoimprinting and press stamping technologies, and the flow pattern between sheets generated by rotating the 3DStack were potential contributors to a more sensitive ELISA-based diagnostic device.

  10. High Temperature and High Sensitive NOx Gas Sensor with Hetero-Junction Structure using Laser Ablation Method

    Science.gov (United States)

    Gao, Wei; Shi, Liqin; Hasegawa, Yuki; Katsube, Teruaki

    In order to develop a high temperature (200°C˜400°C) and high sensitive NOx gas sensor, we developed a new structure of SiC-based hetero-junction device Pt/SnO2/SiC/Ni, Pt/In2O3/SiC/Ni and Pt/WO3/SiC/Ni using a laser ablation method for the preparation of both metal (Pt) electrode and metal-oxide film. It was found that Pt/In2O3/SiC/Ni sensor shows higher sensitivity to NO2 gas compared with the Pt/SnO2/SiC/Ni and Pt/WO3/SiC/Ni sensor, whereas the Pt/WO3/SiC/Ni sensor had better sensitivity to NO gas. These results suggest that selective detection of NO and NO2 gases may be obtained by choosing different metal oxide films.

  11. The nature and nurture of high IQ: an extended sensitive period for intellectual development.

    Science.gov (United States)

    Brant, Angela M; Munakata, Yuko; Boomsma, Dorret I; Defries, John C; Haworth, Claire M A; Keller, Matthew C; Martin, Nicholas G; McGue, Matthew; Petrill, Stephen A; Plomin, Robert; Wadsworth, Sally J; Wright, Margaret J; Hewitt, John K

    2013-08-01

    IQ predicts many measures of life success, as well as trajectories of brain development. Prolonged cortical thickening observed in individuals with high IQ might reflect an extended period of synaptogenesis and high environmental sensitivity or plasticity. We tested this hypothesis by examining the timing of changes in the magnitude of genetic and environmental influences on IQ as a function of IQ score. We found that individuals with high IQ show high environmental influence on IQ into adolescence (resembling younger children), whereas individuals with low IQ show high heritability of IQ in adolescence (resembling adults), a pattern consistent with an extended sensitive period for intellectual development in more-intelligent individuals. The pattern held across a cross-sectional sample of almost 11,000 twin pairs and a longitudinal sample of twins, biological siblings, and adoptive siblings.

  12. High Throughput Measurement of Locomotor Sensitization to Volatilized Cocaine in Drosophila melanogaster.

    Science.gov (United States)

    Filošević, Ana; Al-Samarai, Sabina; Andretić Waldowski, Rozi

    2018-01-01

    Drosophila melanogaster can be used to identify genes with novel functional roles in neuronal plasticity induced by repeated consumption of addictive drugs. Behavioral sensitization is a relatively simple behavioral output of plastic changes that occur in the brain after repeated exposures to drugs of abuse. The development of screening procedures for genes that control behavioral sensitization has stalled due to a lack of high-throughput behavioral tests that can be used in genetically tractable organism, such as Drosophila . We have developed a new behavioral test, FlyBong, which combines delivery of volatilized cocaine (vCOC) to individually housed flies with objective quantification of their locomotor activity. There are two main advantages of FlyBong: it is high-throughput and it allows for comparisons of locomotor activity of individual flies before and after single or multiple exposures. At the population level, exposure to vCOC leads to transient and concentration-dependent increase in locomotor activity, representing sensitivity to an acute dose. A second exposure leads to further increase in locomotion, representing locomotor sensitization. We validate FlyBong by showing that locomotor sensitization at either the population or individual level is absent in the mutants for circadian genes period (per) , Clock (Clk) , and cycle (cyc) . The locomotor sensitization that is present in timeless (tim) and pigment dispersing factor (pdf) mutant flies is in large part not cocaine specific, but derived from increased sensitivity to warm air. Circadian genes are not only integral part of the neural mechanism that is required for development of locomotor sensitization, but in addition, they modulate the intensity of locomotor sensitization as a function of the time of day. Motor-activating effects of cocaine are sexually dimorphic and require a functional dopaminergic transporter. FlyBong is a new and improved method for inducing and measuring locomotor sensitization

  13. High Throughput Measurement of Locomotor Sensitization to Volatilized Cocaine in Drosophila melanogaster

    Directory of Open Access Journals (Sweden)

    Ana Filošević

    2018-02-01

    Full Text Available Drosophila melanogaster can be used to identify genes with novel functional roles in neuronal plasticity induced by repeated consumption of addictive drugs. Behavioral sensitization is a relatively simple behavioral output of plastic changes that occur in the brain after repeated exposures to drugs of abuse. The development of screening procedures for genes that control behavioral sensitization has stalled due to a lack of high-throughput behavioral tests that can be used in genetically tractable organism, such as Drosophila. We have developed a new behavioral test, FlyBong, which combines delivery of volatilized cocaine (vCOC to individually housed flies with objective quantification of their locomotor activity. There are two main advantages of FlyBong: it is high-throughput and it allows for comparisons of locomotor activity of individual flies before and after single or multiple exposures. At the population level, exposure to vCOC leads to transient and concentration-dependent increase in locomotor activity, representing sensitivity to an acute dose. A second exposure leads to further increase in locomotion, representing locomotor sensitization. We validate FlyBong by showing that locomotor sensitization at either the population or individual level is absent in the mutants for circadian genes period (per, Clock (Clk, and cycle (cyc. The locomotor sensitization that is present in timeless (tim and pigment dispersing factor (pdf mutant flies is in large part not cocaine specific, but derived from increased sensitivity to warm air. Circadian genes are not only integral part of the neural mechanism that is required for development of locomotor sensitization, but in addition, they modulate the intensity of locomotor sensitization as a function of the time of day. Motor-activating effects of cocaine are sexually dimorphic and require a functional dopaminergic transporter. FlyBong is a new and improved method for inducing and measuring locomotor

  14. A highly sensitive RF-to-DC power converter with an extended dynamic range

    KAUST Repository

    Almansouri, Abdullah Saud Mohammed

    2017-10-24

    This paper proposes a highly sensitive RF-to-DC power converter with an extended dynamic range that is designed to operate at the medical band 433 MHz and simulated using 0.18 μm CMOS technology. Compared to the conventional fully cross-coupled rectifier, the proposed design offers 3.2× the dynamic range. It is also highly sensitive and requires −18 dBm of input power to produce a 1 V-output voltage when operating with a 100 kΩ load. Furthermore, the proposed design offers an open circuit sensitivity of −23.4 dBm and a peak power conversion efficiency of 67%.

  15. A wide range and highly sensitive optical fiber pH sensor using polyacrylamide hydrogel

    Science.gov (United States)

    Pathak, Akhilesh Kumar; Singh, Vinod Kumar

    2017-12-01

    In the present study we report the fabrication and characterization of no-core fiber sensor (NCFS) using smart hydrogel coating for pH measurement. The no-core fiber (NCF) is stubbed between two single-mode fibers with SMA connector before immobilizing of smart hydrogel. The wavelength interrogation technique is used to calculate the sensitivity of the proposed sensor. The result shows a high sensitivity of 1.94 nm/pH for a wide range of pH values varied from 3 to 10 with a good linear response. In addition to high sensitivity, the fabricated sensor provides a fast response time with a good stability, repeatability and reproducibility.

  16. High-sensitivity visualization of localized electric fields using low-energy electron beam deflection

    Science.gov (United States)

    Jeong, Samuel; Ito, Yoshikazu; Edwards, Gary; Fujita, Jun-ichi

    2018-06-01

    The visualization of localized electronic charges on nanocatalysts is expected to yield fundamental information about catalytic reaction mechanisms. We have developed a high-sensitivity detection technique for the visualization of localized charges on a catalyst and their corresponding electric field distribution, using a low-energy beam of 1 to 5 keV electrons and a high-sensitivity scanning transmission electron microscope (STEM) detector. The highest sensitivity for visualizing a localized electric field was ∼0.08 V/µm at a distance of ∼17 µm from a localized charge at 1 keV of the primary electron energy, and a weak local electric field produced by 200 electrons accumulated on the carbon nanotube (CNT) apex can be visualized. We also observed that Au nanoparticles distributed on a CNT forest tended to accumulate a certain amount of charges, about 150 electrons, at a ‑2 V bias.

  17. High Excitation Transfer Efficiency from Energy Relay Dyes in Dye-Sensitized Solar Cells

    KAUST Repository

    Hardin, Brian E.

    2010-08-11

    The energy relay dye, 4-(Dicyanomethylene)-2-methyl-6-(4- dimethylaminostyryl)-4H-pyran (DCM), was used with a near-infrared sensitizing dye, TT1, to increase the overall power conversion efficiency of a dye-sensitized solar cell (DSC) from 3.5% to 4.5%. The unattached DCM dyes exhibit an average excitation transfer efficiency (EÌ?TE) of 96% inside TT1-covered, mesostructured TiO2 films. Further performance increases were limited by the solubility of DCM in an acetonitrile based electrolyte. This demonstration shows that energy relay dyes can be efficiently implemented in optimized dye-sensitized solar cells, but also highlights the need to design highly soluble energy relay dyes with high molar extinction coefficients. © 2010 American Chemical Society.

  18. High sensitivity optical fiber liquid level sensor based on a compact MMF-HCF-FBG structure

    Science.gov (United States)

    Zhang, Yunshan; Zhang, Weigang; Chen, Lei; Zhang, Yanxin; Wang, Song; Yan, Tieyi

    2018-05-01

    An ultra-high sensitivity fiber liquid level sensor based on wavelength demodulation is proposed and demonstrated. The sensor is composed of a segment of multimode fiber and a large aperture hollow-core fiber assisted by a fiber Bragg grating (FBG). Interference occurs due to core mismatching and different modes with different effective refractive indices. The experimental results show that the liquid level sensitivity of the sensor is 1.145 nm mm‑1, and the linearity is up to 0.996. The dynamic temperature compensation of the sensor can be achieved by cascading an FBG. Considering the high sensitivity and compact structure of the sensor, it can be used for real-time intelligent monitoring of tiny changes in liquid level.

  19. Niacin Skin Sensitivity Is Increased in Adolescents at Ultra-High Risk for Psychosis.

    Directory of Open Access Journals (Sweden)

    Gregor E Berger

    Full Text Available Most studies provide evidence that the skin flush response to nicotinic acid (niacin stimulation is impaired in schizophrenia. However, only little is known about niacin sensitivity in the ultra-high risk (UHR phase of psychotic disorders.We compared visual ratings of niacin sensitivity between adolescents at UHR for psychosis according to the one year transition outcome (UHR-T n = 11; UHR-NT n = 55 with healthy controls (HC n = 25 and first episode schizophrenia patients (FEP n = 25 treated with atypical antipsychotics.Contrary to our hypothesis niacin sensitivity of the entire UHR group was not attenuated, but significantly increased compared to the HC group, whereas no difference could be found between the UHR-T and UHR-NT groups. As expected, niacin sensitivity of FEP was attenuated compared to HC group. In UHR individuals niacin sensitivity was inversely correlated with omega-6 and -9 fatty acids (FA, but positively correlated with phospholipase A2 (inPLA2 activity, a marker of membrane lipid repair/remodelling.Increased niacin sensitivity in UHR states likely indicates an impaired balance of eicosanoids and omega-6/-9 FA at a membrane level. Our findings suggest that the emergence of psychosis is associated with an increased mobilisation of eicosanoids prior to the transition to psychosis possibly reflecting a "pro-inflammatory state", whereas thereafter eicosanoid mobilisation seems to be attenuated. Potential treatment implications for the UHR state should be further investigated.

  20. Development of Charge Sensitive Preamplifier and Readout Integrate Circuit Board for High Resolution Detector using ASIC Process

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, J. Y.; Kim, J. H.; Park, J. M.; Yang, J. Y.; Kim, K. Y.; Kim, Y. S. [RadTek Co., Daejeon (Korea, Republic of)

    2010-06-15

    - Design of discrete type charge sensitive amplifier for high resolution semi-conductor sensor - Design and develop the test board for the performance of charge sensitive amplifier with sensor - Performance of electrical test for the sensor and charge sensitive amplifier - Development of prototype 8 x 8 array type detector module - Noise equivalent charge test for the charge sensitive amplifier - Design and development of Micro SMD discrete type amplifier applying ASIC procedure - Development of Hybrid type charge sensitive amplifier including shape

  1. Localized Electrochemiluminescence from Nanoneedle Electrodes for Very-high-density Electrochemical Sensing

    KAUST Repository

    Zhang, Jingjing; Zhou, Junyu; Tian, Chunxiu; Yang, Shan; Jiang, Dechen; Zhang, Xixiang; Chen, Hong-Yuan

    2017-01-01

    over 4 × 103 spots/mm2. The positive correlation between the luminescence intensity at the tips and the concentration of hydrogen peroxide supported the quantitative ECL analysis using nanoneedle electrodes. The further modification of glucose oxidase

  2. Development of a high sensitivity monitor for radionuclides characterization. Final report, August 1995--April 1996

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-06-01

    This report describes the development of a high sensitivity monitor for radiation, and the feasibility of applying a new radiation imaging concept developed for medical research to soil contamination. The concept utilizes sensors with storage photostimulable phosphor technology as radiation detectors. They are applicable to all types of radiation including tritium.

  3. High sensitivity of quick view capsule endoscopy for detection of small bowel Crohn's disease

    DEFF Research Database (Denmark)

    Halling, Morten Lee; Nathan, Torben; Kjeldsen, Jens

    2014-01-01

    Capsule endoscopy (CE) has a high sensitivity for diagnosing small bowel Crohn's disease, but video analysis is time consuming. The quick view (qv) function is an effective tool to reduce time consumption. The aim of this study was to determine the rate of missed small bowel ulcerations with qv-C...

  4. BH5047 type depth sand moisture-meter of high sensitivity

    International Nuclear Information System (INIS)

    Ji Changsong; Xie Liangnian; Zhang Shulan; Zhang Shuheng

    2000-01-01

    A new depth neutron moisture meter BH5047 has been developed. BH5047 neutron moisture meter is characterised by it is high sensitivity and used for sand water content measurement at concrete mixer. Calibration function is obtained by the Method of Least Squares. Linear correlation efficiency is as good as 0.9977

  5. Resting serum concentration of high-sensitivity C-reactive protein ...

    African Journals Online (AJOL)

    Resting serum concentration of high-sensitivity C-reactive protein (hs-CRP) in sportsmen and untrained male adults. F.A. Niyi-Odumosu, O. A. Bello, S.A. Biliaminu, B.V. Owoyele, T.O. Abu, O.L. Dominic ...

  6. A high resolution position sensitive X-ray MWPC for small angle X-ray diffraction

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Tappern, G.J.

    1981-02-01

    A small sealed-off delay line readout MWPC X-ray detector has been designed and built for small angle X-ray diffraction applications. Featuring a sensitive area of 100 mm x 25 mm it yields a spatial resolution of 0.13 mm (standard deviation) with a high rate capability and good quantum efficiency for copper K radiation. (author)

  7. Highly sensitive luminescence method of scandium determination in the products of metallurgical reprocessing

    International Nuclear Information System (INIS)

    Matveets, M.A.; Akhmetova, S.D.

    1988-01-01

    Highly sensitive reaction of scandium with 1,10-phenanthroline and eosin is used for the development of luminescence method of its determination in metallurgical products. The effect of interfering elements is eliminated by scandium extraction with monocarboxylic acids. The method permits to determine scandium content from 5 x 10 -5 % (Sr 0.15 - 0.25)

  8. Label-free biosensing with high sensitivity in dual-core microstructured polymer optical fibers

    DEFF Research Database (Denmark)

    Markos, Christos; Yuan, Wu; Vlachos, Kyriakos

    2011-01-01

    We present experimentally feasible designs of a dual-core microstructured polymer optical fiber (mPOF), which can act as a highly sensitive, label-free, and selective biosensor. An immobilized antigen sensing layer on the walls of the holes in the mPOF provides the ability to selectively capture...

  9. Development of a high sensitivity monitor for radionuclides characterization. Final report, August 1995--April 1996

    International Nuclear Information System (INIS)

    1996-06-01

    This report describes the development of a high sensitivity monitor for radiation, and the feasibility of applying a new radiation imaging concept developed for medical research to soil contamination. The concept utilizes sensors with storage photostimulable phosphor technology as radiation detectors. They are applicable to all types of radiation including tritium

  10. A glycine residue essential for high ivermectin sensitivity in Cys-loop ion channel receptors

    DEFF Research Database (Denmark)

    Lynagh, Timothy; Lynch, Joseph W.

    2010-01-01

    Ivermectin exerts its anthelmintic effect by activating nematode Cys-loop glutamate-gated receptors. Here we show that a glycine residue at a specific transmembrane domain location is essential for high ivermectin sensitivity in both glycine- and glutamate-gated Cys-loop receptors. We also show...

  11. Association between high-sensitive troponin I and coronary artery calcification in a Danish general population

    DEFF Research Database (Denmark)

    Olson, Fredrik; Engborg, Jonathan; Grønhøj, Mette H.

    2016-01-01

    BACKGROUND: High-sensitive troponin I (hs-TnI) is an individual predictor of future cardiovascular disease (CVD). However, the relationship between hs-TnI and coronary artery calcification (CAC) as determined by computed tomography (CT) has not previously been investigated in a general population...

  12. A highly sensitive RF-to-DC power converter with an extended dynamic range

    KAUST Repository

    Almansouri, Abdullah Saud Mohammed; Ouda, Mahmoud H.; Salama, Khaled N.

    2017-01-01

    This paper proposes a highly sensitive RF-to-DC power converter with an extended dynamic range that is designed to operate at the medical band 433 MHz and simulated using 0.18 μm CMOS technology. Compared to the conventional fully cross

  13. Rats bred for high alcohol drinking are more sensitive to delayed and probabilistic outcomes.

    Science.gov (United States)

    Wilhelm, C J; Mitchell, S H

    2008-10-01

    Alcoholics and heavy drinkers score higher on measures of impulsivity than nonalcoholics and light drinkers. This may be because of factors that predate drug exposure (e.g. genetics). This study examined the role of genetics by comparing impulsivity measures in ethanol-naive rats selectively bred based on their high [high alcohol drinking (HAD)] or low [low alcohol drinking (LAD)] consumption of ethanol. Replicates 1 and 2 of the HAD and LAD rats, developed by the University of Indiana Alcohol Research Center, completed two different discounting tasks. Delay discounting examines sensitivity to rewards that are delayed in time and is commonly used to assess 'choice' impulsivity. Probability discounting examines sensitivity to the uncertain delivery of rewards and has been used to assess risk taking and risk assessment. High alcohol drinking rats discounted delayed and probabilistic rewards more steeply than LAD rats. Discount rates associated with probabilistic and delayed rewards were weakly correlated, while bias was strongly correlated with discount rate in both delay and probability discounting. The results suggest that selective breeding for high alcohol consumption selects for animals that are more sensitive to delayed and probabilistic outcomes. Sensitivity to delayed or probabilistic outcomes may be predictive of future drinking in genetically predisposed individuals.

  14. An UPLC-MS/MS method for highly sensitive high-throughput analysis of phytohormones in plant tissues

    Directory of Open Access Journals (Sweden)

    Balcke Gerd Ulrich

    2012-11-01

    Full Text Available Abstract Background Phytohormones are the key metabolites participating in the regulation of multiple functions of plant organism. Among them, jasmonates, as well as abscisic and salicylic acids are responsible for triggering and modulating plant reactions targeted against pathogens and herbivores, as well as resistance to abiotic stress (drought, UV-irradiation and mechanical wounding. These factors induce dramatic changes in phytohormone biosynthesis and transport leading to rapid local and systemic stress responses. Understanding of underlying mechanisms is of principle interest for scientists working in various areas of plant biology. However, highly sensitive, precise and high-throughput methods for quantification of these phytohormones in small samples of plant tissues are still missing. Results Here we present an LC-MS/MS method for fast and highly sensitive determination of jasmonates, abscisic and salicylic acids. A single-step sample preparation procedure based on mixed-mode solid phase extraction was efficiently combined with essential improvements in mobile phase composition yielding higher efficiency of chromatographic separation and MS-sensitivity. This strategy resulted in dramatic increase in overall sensitivity, allowing successful determination of phytohormones in small (less than 50 mg of fresh weight tissue samples. The method was completely validated in terms of analyte recovery, sensitivity, linearity and precision. Additionally, it was cross-validated with a well-established GC-MS-based procedure and its applicability to a variety of plant species and organs was verified. Conclusion The method can be applied for the analyses of target phytohormones in small tissue samples obtained from any plant species and/or plant part relying on any commercially available (even less sensitive tandem mass spectrometry instrumentation.

  15. Addressing Curse of Dimensionality in Sensitivity Analysis: How Can We Handle High-Dimensional Problems?

    Science.gov (United States)

    Safaei, S.; Haghnegahdar, A.; Razavi, S.

    2016-12-01

    Complex environmental models are now the primary tool to inform decision makers for the current or future management of environmental resources under the climate and environmental changes. These complex models often contain a large number of parameters that need to be determined by a computationally intensive calibration procedure. Sensitivity analysis (SA) is a very useful tool that not only allows for understanding the model behavior, but also helps in reducing the number of calibration parameters by identifying unimportant ones. The issue is that most global sensitivity techniques are highly computationally demanding themselves for generating robust and stable sensitivity metrics over the entire model response surface. Recently, a novel global sensitivity analysis method, Variogram Analysis of Response Surfaces (VARS), is introduced that can efficiently provide a comprehensive assessment of global sensitivity using the Variogram concept. In this work, we aim to evaluate the effectiveness of this highly efficient GSA method in saving computational burden, when applied to systems with extra-large number of input factors ( 100). We use a test function and a hydrological modelling case study to demonstrate the capability of VARS method in reducing problem dimensionality by identifying important vs unimportant input factors.

  16. A High-Sensitivity Potentiometric 65-nm CMOS ISFET Sensor for Rapid E. coli Screening.

    Science.gov (United States)

    Jiang, Yu; Liu, Xu; Dang, Tran Chien; Huang, Xiwei; Feng, Hao; Zhang, Qing; Yu, Hao

    2018-04-01

    Foodborne bacteria, inducing outbreaks of infection or poisoning, have posed great threats to food safety. Potentiometric sensors can identify bacteria levels in food by measuring medium's pH changes. However, most of these sensors face the limitation of low sensitivity and high cost. In this paper, we developed a high-sensitivity ion-sensitive field-effect transistor sensor. It is small sized, cost-efficient, and can be massively fabricated in a standard 65-nm complementary metal-oxide-semiconductor process. A subthreshold pH-to-time-to-voltage conversion scheme was proposed to improve the sensitivity. Furthermore, design parameters, such as chemical sensing area, transistor size, and discharging time, were optimized to enhance the performance. The intrinsic sensitivity of passivation membrane was calculated as 33.2 mV/pH. It was amplified to 123.8 mV/pH with a 0.01-pH resolution, which greatly exceeded 6.3 mV/pH observed in a traditional source-follower based readout structure. The sensing system was applied to Escherichia coli (E. coli) detection with densities ranging from 14 to 140 cfu/mL. Compared to the conventional direct plate counting method (24 h), more efficient sixfold smaller screening time (4 h) was achieved to differentiate samples' E. coli levels. The demonstrated portable, time-saving, and low-cost prescreen system has great potential for food safety detection.

  17. Polarization-sensitive and broadband germanium sulfide photodetectors with excellent high-temperature performance.

    Science.gov (United States)

    Tan, Dezhi; Zhang, Wenjin; Wang, Xiaofan; Koirala, Sandhaya; Miyauchi, Yuhei; Matsuda, Kazunari

    2017-08-31

    Layered materials, such as graphene, transition metal dichalcogenides and black phosphorene, have been established rapidly as intriguing building blocks for optoelectronic devices. Here, we introduce highly polarization sensitive, broadband, and high-temperature-operation photodetectors based on multilayer germanium sulfide (GeS). The GeS photodetector shows a high photoresponsivity of about 6.8 × 10 3 A W -1 , an extremely high specific detectivity of 5.6 × 10 14 Jones, and broad spectral response in the wavelength range of 300-800 nm. More importantly, the GeS photodetector has high polarization sensitivity to incident linearly polarized light, which provides another degree of freedom for photodetectors. Tremendously enhanced photoresponsivity is observed with a temperature increase, and high responsivity is achievable at least up to 423 K. The establishment of larger photoinduced reduction of the Schottky barrier height will be significant for the investigation of the photoresponse mechanism of 2D layered material-based photodetectors. These attributes of high photocurrent generation in a wide temperature range, broad spectral response, and polarization sensitivity coupled with environmental stability indicate that the proposed GeS photodetector is very suitable for optoelectronic applications.

  18. Temperature uniformity mapping in a high pressure high temperature reactor using a temperature sensitive indicator

    NARCIS (Netherlands)

    Grauwet, T.; Plancken, van der I.; Vervoort, L.; Matser, A.M.; Hendrickx, M.; Loey, van A.

    2011-01-01

    Recently, the first prototype ovomucoid-based pressure–temperature–time indicator (pTTI) for high pressure high temperature (HPHT) processing was described. However, for temperature uniformity mapping of high pressure (HP) vessels under HPHT sterilization conditions, this prototype needs to be

  19. Highly-sensitive and large-dynamic diffuse optical tomography system for breast tumor detection

    Science.gov (United States)

    Du, Wenwen; Zhang, Limin; Yin, Guoyan; Zhang, Yanqi; Zhao, Huijuan; Gao, Feng

    2018-02-01

    Diffuse optical tomography (DOT) as a new functional imaging has important clinical applications in many aspects such as benign and malignant breast tumor detection, tumor staging and so on. For quantitative detection of breast tumor, a three-wavelength continuous-wave DOT prototype system combined the ultra-high sensitivity of the photon-counting detection and the measurement parallelism of the lock-in technique was developed to provide high temporal resolution, high sensitivity, large dynamic detection range and signal-to-noise ratio. Additionally, a CT-analogous scanning mode was proposed to cost-effectively increase the detection data. To evaluate the feasibility of the system, a series of assessments were conducted. The results demonstrate that the system can obtain high linearity, stability and negligible inter-wavelength crosstalk. The preliminary phantom experiments show the absorption coefficient is able to be successfully reconstructed, indicating that the system is one of the ideal platforms for optical breast tumor detection.

  20. Confidentiality Enhancement of Highly Sensitive Nuclear Data Using Steganography with Chaotic Encryption over OFDM Channel

    International Nuclear Information System (INIS)

    Mahmoud, S.; Ayad, N.; Elsayed, F.; Elbendary, M.

    2016-01-01

    Full text: Due to the widespread usage of the internet and other wired and wireless communication methods, the security of the transmitted data has become a major requirement. Nuclear knowledge is mainly built upon the exchange of nuclear information which is considered highly sensitive information, so its security has to be enhanced by using high level security mechanisms. Data confidentiality is concerned with the achievement of higher protection for confidential information from unauthorized disclosure or access. Cryptography and steganography are famous and widely used techniques that process information in order to achieve its confidentiality, but sometimes, when used individually, they don’t satisfy a required level of security for highly sensitive data. In this paper, cryptography is accompanied with steganography for constituting a multilayer security techniques that can strengthen the level of security of highly confidential nuclear data that are archived or transmitted through different channel types and noise conditions. (author)

  1. Sensitivity of MENA Tropical Rainbelt to Dust Shortwave Absorption: A High Resolution AGCM Experiment

    KAUST Repository

    Bangalath, Hamza Kunhu

    2016-06-13

    Shortwave absorption is one of the most important, but the most uncertain, components of direct radiative effect by mineral dust. It has a broad range of estimates from different observational and modeling studies and there is no consensus on the strength of absorption. To elucidate the sensitivity of the Middle East and North Africa (MENA) tropical summer rainbelt to a plausible range of uncertainty in dust shortwave absorption, AMIP-style global high resolution (25 km) simulations are conducted with and without dust, using the High-Resolution Atmospheric Model (HiRAM). Simulations with dust comprise three different cases by assuming dust as a very efficient, standard and inefficient absorber. Inter-comparison of these simulations shows that the response of the MENA tropical rainbelt is extremely sensitive to the strength of shortwave absorption. Further analyses reveal that the sensitivity of the rainbelt stems from the sensitivity of the multi-scale circulations that define the rainbelt. The maximum response and sensitivity are predicted over the northern edge of the rainbelt, geographically over Sahel. The sensitivity of the responses over the Sahel, especially that of precipitation, is comparable to the mean state. Locally, the response in precipitation reaches up to 50% of the mean, while dust is assumed to be a very efficient absorber. Taking into account that Sahel has a very high climate variability and is extremely vulnerable to changes in precipitation, the present study suggests the importance of reducing uncertainty in dust shortwave absorption for a better simulation and interpretation of the Sahel climate.

  2. Sensitivity of MENA Tropical Rainbelt to Dust Shortwave Absorption: A High Resolution AGCM Experiment

    KAUST Repository

    Bangalath, Hamza Kunhu; Stenchikov, Georgiy L.

    2016-01-01

    Shortwave absorption is one of the most important, but the most uncertain, components of direct radiative effect by mineral dust. It has a broad range of estimates from different observational and modeling studies and there is no consensus on the strength of absorption. To elucidate the sensitivity of the Middle East and North Africa (MENA) tropical summer rainbelt to a plausible range of uncertainty in dust shortwave absorption, AMIP-style global high resolution (25 km) simulations are conducted with and without dust, using the High-Resolution Atmospheric Model (HiRAM). Simulations with dust comprise three different cases by assuming dust as a very efficient, standard and inefficient absorber. Inter-comparison of these simulations shows that the response of the MENA tropical rainbelt is extremely sensitive to the strength of shortwave absorption. Further analyses reveal that the sensitivity of the rainbelt stems from the sensitivity of the multi-scale circulations that define the rainbelt. The maximum response and sensitivity are predicted over the northern edge of the rainbelt, geographically over Sahel. The sensitivity of the responses over the Sahel, especially that of precipitation, is comparable to the mean state. Locally, the response in precipitation reaches up to 50% of the mean, while dust is assumed to be a very efficient absorber. Taking into account that Sahel has a very high climate variability and is extremely vulnerable to changes in precipitation, the present study suggests the importance of reducing uncertainty in dust shortwave absorption for a better simulation and interpretation of the Sahel climate.

  3. 12th Rencontres du Vietnam : High Sensitivity Experiments Beyond the Standard Model

    CERN Document Server

    2016-01-01

    The goal of this workshop is to gather researchers, theoreticians, experimentalists and young scientists searching for physics beyond the Standard Model of particle physics using high sensitivity experiments. The standard model has been very successful in describing the particle physics world; the Higgs-Englert-Brout boson discovery is its last major discovery. Complementary to the high energy frontier explored at colliders, real opportunities for discovery exist at the precision frontier, testing fundamental symmetries and tracking small SM deviations.

  4. Highly sensitive electrochemical determination of 1-naphthol based on high-index facet SnO2 modified electrode

    International Nuclear Information System (INIS)

    Huang Xiaofeng; Zhao Guohua; Liu Meichuan; Li Fengting; Qiao Junlian; Zhao Sichen

    2012-01-01

    Highlights: ► It is the first time to employ high-index faceted SnO 2 in electrochemical analysis. ► High-index faceted SnO 2 has excellent electrochemical activity toward 1-naphthol. ► Highly sensitive determination of 1-naphthol is realized on high-index faceted SnO 2 . ► The detection limit of 1-naphthol is as low as 5 nM on high-index faceted SnO 2 . ► Electro-oxidation kinetics for 1-napthol on the novel electrode is discussed. - Abstract: SnO 2 nanooctahedron with {2 2 1} high-index facet (HIF) was synthesized by a simple hydrothermal method, and was firstly employed to sensitive electrochemical sensing of a typical organic pollutant, 1-naphthol (1-NAP). The constructed HIF SnO 2 modified glassy carbon electrode (HIF SnO 2 /GCE) possessed advantages of large effective electrode area, high electron transfer rate, and low charge transfer resistance. These improved electrochemical properties allowed the high electrocatalytic performance, high effective active sites and high adsorption capacity of 1-NAP on HIF SnO 2 /GCE. Cyclic voltammetry (CV) results showed that the electrochemical oxidation of 1-NAP obeyed a two-electron transfer process and the electrode reaction was under diffusion control on HIF SnO 2 /GCE. By adopting differential pulse voltammetry (DPV), electrochemical detection of 1-NAP was conducted on HIF SnO 2 /GCE with a limit of detection as low as 5 nM, which was relatively low compared to the literatures. The electrode also illustrated good stability in comparison with those reported value. Satisfactory results were obtained with average recoveries in the range of 99.7–103.6% in the real water sample detection. A promising device for the electrochemical detection of 1-NAP with high sensitivity has therefore been provided.

  5. High-field modulated ion-selective field-effect-transistor (FET) sensors with sensitivity higher than the ideal Nernst sensitivity.

    Science.gov (United States)

    Chen, Yi-Ting; Sarangadharan, Indu; Sukesan, Revathi; Hseih, Ching-Yen; Lee, Geng-Yen; Chyi, Jen-Inn; Wang, Yu-Lin

    2018-05-29

    Lead ion selective membrane (Pb-ISM) coated AlGaN/GaN high electron mobility transistors (HEMT) was used to demonstrate a whole new methodology for ion-selective FET sensors, which can create ultra-high sensitivity (-36 mV/log [Pb 2+ ]) surpassing the limit of ideal sensitivity (-29.58 mV/log [Pb 2+ ]) in a typical Nernst equation for lead ion. The largely improved sensitivity has tremendously reduced the detection limit (10 -10  M) for several orders of magnitude of lead ion concentration compared to typical ion-selective electrode (ISE) (10 -7  M). The high sensitivity was obtained by creating a strong filed between the gate electrode and the HEMT channel. Systematical investigation was done by measuring different design of the sensor and gate bias, indicating ultra-high sensitivity and ultra-low detection limit obtained only in sufficiently strong field. Theoretical study in the sensitivity consistently agrees with the experimental finding and predicts the maximum and minimum sensitivity. The detection limit of our sensor is comparable to that of Inductively-Coupled-Plasma Mass Spectrum (ICP-MS), which also has detection limit near 10 -10  M.

  6. The Effect of a Diet Moderately High in Protein and Fiber on Insulin Sensitivity Measured Using the Dynamic Insulin Sensitivity and Secretion Test (DISST

    Directory of Open Access Journals (Sweden)

    Lisa Te Morenga

    2017-11-01

    Full Text Available Evidence shows that weight loss improves insulin sensitivity but few studies have examined the effect of macronutrient composition independently of weight loss on direct measures of insulin sensitivity. We randomised 89 overweight or obese women to either a standard diet (StdD, that was intended to be low in fat and relatively high in carbohydrate (n = 42 or to a relatively high protein (up to 30% of energy, relatively high fibre (>30 g/day diet (HPHFib (n = 47 for 10 weeks. Advice regarding strict adherence to energy intake goals was not given. Insulin sensitivity and secretion was assessed by a novel method—the Dynamic Insulin Sensitivity and Secretion Test (DISST. Although there were significant improvements in body composition and most cardiometabolic risk factors on HPHFib, insulin sensitivity was reduced by 19.3% (95% CI: 31.8%, 4.5%; p = 0.013 in comparison with StdD. We conclude that the reduction in insulin sensitivity after a diet relatively high in both protein and fibre, despite cardiometabolic improvements, suggests insulin sensitivity may reflect metabolic adaptations to dietary composition for maintenance of glucose homeostasis, rather than impaired metabolism.

  7. Development of an ozone high sensitive sensor working at ambient temperature

    International Nuclear Information System (INIS)

    Berger, F; Ghaddab, B; Sanchez, J B; Mavon, C

    2011-01-01

    Hybrid SnO 2 /SWNTs thin layer were deposited by using sol-gel process. Such sensitive layers showed very high performances for O 3 flow detection at ambient temperature. Limit sensitivity, lower than 21,5 ppb of O 3 in air has been reached by using these hybrid layers. Compared to usefull metal oxide sensors, the main advantage of the use of such hybrid layers, is that these devices enable the detection of O 3 traces at room temperature. The influence of sensor's working temperature is discussed and finally a reactional mechanism for the detection of O 3 is proposed.

  8. Highly sensitive heavy metal ion detection using AlQ3 microwire functionalized QCM

    Science.gov (United States)

    Can, Nursel; Aǧar, Meltem; Altındal, Ahmet

    2016-03-01

    Tris(8-hydroxyquinoline) aluminum (Alq3) microwires was successfully synthesized for the fabrication of Alq3 microwires-coated QCM sensors to detect the heavy metal ions in aqueous solution. AT-cut quartz crystal microbalance (QCM) of 10 MHz fundamental resonance frequency having gold electrodes were used as transducers. Typical measuring cycle consisted of repeated flow of target measurands through the flow cell and subsequent washing to return the baseline. The QCM results indicated that the Alq3 microwires exhibit excellent sensitivity, stability and short response-recovery time, which are much attractive for the development of portable and highly sensitive heavy metal ion sensors in water samples.

  9. High sensitivity optical biosensor based on polymer materials and using the Vernier effect.

    Science.gov (United States)

    Azuelos, Paul; Girault, Pauline; Lorrain, Nathalie; Poffo, Luiz; Guendouz, Mohammed; Thual, Monique; Lemaître, Jonathan; Pirasteh, Parastesh; Hardy, Isabelle; Charrier, Joël

    2017-11-27

    We demonstrate the fabrication of a Vernier effect SU8/PMATRIFE polymer optical biosensor with high homogeneous sensitivity using a standard photolithography process. The sensor is based on one micro-resonator embedded on each arm of a Mach-Zehnder interferometer. Measurements are based on the refractive index variation of the optical waveguide superstrate with different concentrations of glucose solutions. The sensitivity of the sensor has been measured as 17558 nm/RIU and the limit of detection has been estimated to 1.1.10 -6 RIU.

  10. Study of extraterrestrial material by means of a high sensitive mass spectrometer, 1

    International Nuclear Information System (INIS)

    Arai, O.; Kaneko, K.; Kobayashi, K.; Shimamura, T.

    1975-01-01

    In this report it is described about a high sensitive mass spectrometer for measurement of isotopic abundance of extraterrestrial material. Detecting isotopic anomalies in extraterrestrial matter induced by cosmic ray or solar wind irradiation, we can obtain many informations about interplanetary and/or intersteller space. For this purpose we reform the mass spectrometer of Low Energy Physics Division of INS to improve the sensitivity and the resolution. In section I--VI some improvements of the mass spectrometer (vacuum system, ion source, collector etc.) are described. In section VII--X newly developed ion counting system is discussed. (auth.)

  11. Precisely Controlled Ultrathin Conjugated Polymer Films for Large Area Transparent Transistors and Highly Sensitive Chemical Sensors.

    Science.gov (United States)

    Khim, Dongyoon; Ryu, Gi-Seong; Park, Won-Tae; Kim, Hyunchul; Lee, Myungwon; Noh, Yong-Young

    2016-04-13

    A uniform ultrathin polymer film is deposited over a large area with molecularlevel precision by the simple wire-wound bar-coating method. The bar-coated ultrathin films not only exhibit high transparency of up to 90% in the visible wavelength range but also high charge carrier mobility with a high degree of percolation through the uniformly covered polymer nanofibrils. They are capable of realizing highly sensitive multigas sensors and represent the first successful report of ethylene detection using a sensor based on organic field-effect transistors. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Highly sensitive voltammetric biosensor for nitric oxide based on its high affinity with hemoglobin

    International Nuclear Information System (INIS)

    Fan Chunhai; Liu Xinjian; Pang Jiantao; Li Genxi; Scheer, Hugo

    2004-01-01

    Although heme protein-based, amperometric nitric oxide (NO) biosensors have been well documented in previous studies, most have been conducted in anaerobic conditions. Herein we report a novel hemoglobin-based NO biosensor that is not only very sensitive but also usable in air. The heme protein was entrapped in a sodium montmorillonite film, which was immobilized at a pyrolytic graphite electrode surface. Film-entrapped hemoglobin can directly exchange electrons with the electrode, and this process has proven to favor the catalytic reduction of oxygen. In addition, NO induced a cathodic potential shift of the catalytic reduction peak of oxygen. This potential shift was proportional to the logarithm of NO concentration ranging from 4.0 x 10 -11 to 5.0 x 10 -6 mol/L. The detection limit has been estimated to be 20 pM, approximately four orders lower than previously reported amperometric detectors

  13. Chemically Designed Metallic/Insulating Hybrid Nanostructures with Silver Nanocrystals for Highly Sensitive Wearable Pressure Sensors.

    Science.gov (United States)

    Kim, Haneun; Lee, Seung-Wook; Joh, Hyungmok; Seong, Mingi; Lee, Woo Seok; Kang, Min Su; Pyo, Jun Beom; Oh, Soong Ju

    2018-01-10

    With the increase in interest in wearable tactile pressure sensors for e-skin, researches to make nanostructures to achieve high sensitivity have been actively conducted. However, limitations such as complex fabrication processes using expensive equipment still exist. Herein, simple lithography-free techniques to develop pyramid-like metal/insulator hybrid nanostructures utilizing nanocrystals (NCs) are demonstrated. Ligand-exchanged and unexchanged silver NC thin films are used as metallic and insulating components, respectively. The interfaces of each NC layer are chemically engineered to create discontinuous insulating layers, i.e., spacers for improved sensitivity, and eventually to realize fully solution-processed pressure sensors. Device performance analysis with structural, chemical, and electronic characterization and conductive atomic force microscopy study reveals that hybrid nanostructure based pressure sensor shows an enhanced sensitivity of higher than 500 kPa -1 , reliability, and low power consumption with a wide range of pressure sensing. Nano-/micro-hierarchical structures are also designed by combining hybrid nanostructures with conventional microstructures, exhibiting further enhanced sensing range and achieving a record sensitivity of 2.72 × 10 4 kPa -1 . Finally, all-solution-processed pressure sensor arrays with high pixel density, capable of detecting delicate signals with high spatial selectivity much better than the human tactile threshold, are introduced.

  14. Palladium Gate All Around - Hetero Dielectric -Tunnel FET based highly sensitive Hydrogen Gas Sensor

    Science.gov (United States)

    Madan, Jaya; Chaujar, Rishu

    2016-12-01

    The paper presents a novel highly sensitive Hetero-Dielectric-Gate All Around Tunneling FET (HD-GAA-TFET) based Hydrogen Gas Sensor, incorporating the advantages of band to band tunneling (BTBT) mechanism. Here, the Palladium supported silicon dioxide is used as a sensing media and sensing relies on the interaction of hydrogen with Palladium-SiO2-Si. The high surface to volume ratio in the case of cylindrical GAA structure enhances the fortuities for surface reactions between H2 gas and Pd, and thus improves the sensitivity and stability of the sensor. Behaviour of the sensor in presence of hydrogen and at elevated temperatures is discussed. The conduction path of the sensor which is dependent on sensors radius has also been varied for the optimized sensitivity and static performance analysis of the sensor where the proposed design exhibits a superior performance in terms of threshold voltage, subthreshold swing, and band to band tunneling rate. Stability of the sensor with respect to temperature affectability has also been studied, and it is found that the device is reasonably stable and highly sensitive over the bearable temperature range. The successful utilization of HD-GAA-TFET in gas sensors may open a new door for the development of novel nanostructure gas sensing devices.

  15. The fabrication of high sensitivity gold nanorod H2S gas sensors utilizing the highly uniform anodic aluminum oxide template

    Directory of Open Access Journals (Sweden)

    Chien-Yu Li

    2016-12-01

    Full Text Available Gold nanorod were fabricated using anodic alumina oxide template for H2S gas detection. The nanorod gas sensor exhibits high surface density and contact area, which can increase detection sensitivity. The anodic alumina oxide template contains an array of pores, with a width of 70 nm and a length of 27μm. Au nanorod were obtained through electro-deposition under a pulse bias of −1 V. The resistance of the Au nanorod was recorded upon exposure to various concentrations of H2S. The resistance could be attributed to the high electron affinity between sulfide and Au nanorod. Au–sulfide bonds provide strong bonding, which could alter the conductivity of the sensor. The gas sensor exhibits high sensitivity and short response time for H2S detection at room temperature.

  16. Electrochemiluminescence properties of Tb(III) nicotinic acid complex and its analytical application

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yu [College of Chemistry and Material Science, Anhui Normal University, No. 1 Beijing East Road, Wuhu 241000 (China); Zhang, Yuqin [The Department of Material Engineering, Wuhu Institute of Technology, No. 201 Wenjin Road, Wuhu 241003 (China); Shu, Guibo; Dong, Qin; Zou, Lili [College of Chemistry and Material Science, Anhui Normal University, No. 1 Beijing East Road, Wuhu 241000 (China); Zhu, Yinggui, E-mail: ygzhu08@mail.ahnu.edu.cn [College of Chemistry and Material Science, Anhui Normal University, No. 1 Beijing East Road, Wuhu 241000 (China)

    2015-03-15

    A water soluble lanthanide Tb(III) complex Tb{sub 2}(C{sub 6}NO{sub 2}H{sub 4}){sub 6}(H{sub 2}O){sub 4} has been synthesized as luminescent material, and it is characterized by X-ray crystallography, infrared spectra and elemental analysis, respectively. This material showed excellent characterize of electrochemiluminescence (ECL) in the presence of co-reactant potassium peroxodisulfate (K{sub 2}S{sub 2}O{sub 8}) at glassy carbon electrode. With the increase of the concentration for nicotinic acid (NA), the ECL intensity of the complex/K{sub 2}S{sub 2}O{sub 8} system in HAc–NaAc buffer solution will be decreased apparently. Novel approach for the detection of nicotinic acid (NA) was developed based on the quenching effect of NA. Furthermore, the possible mechanisms for the ECL behavior of Tb{sub 2}(C{sub 6}NO{sub 2}H{sub 4}){sub 6}(H{sub 2}O){sub 4}/K{sub 2}S{sub 2}O{sub 8} system are proposed. The effects of K{sub 2}S{sub 2}O{sub 8} concentration, pH of the buffer on the ECL intensity have also been discussed in detail. The experiment results showed that the limit of detection for NA was 6.0×10{sup −7} M (S/N=3) with a linear range of 2.0×10{sup −6}–2.0×10{sup −4} M. - Highlights: • A novel ECL material Tb{sub 2}(H{sub 2}O){sub 4}(C{sub 6}NO{sub 2}H{sub 4}){sub 6} was synthesized and characterized. • The ECL property of the terbium chelate has been studied detail, and possible mechanism was been proposed. • A new ECL method for the determination of nicotinic acid with a wide liner range and a low detection limit was proposed.

  17. Solution-processable electrochemiluminescent ion gels for flexible, low-voltage, emissive displays on plastic.

    Science.gov (United States)

    Moon, Hong Chul; Lodge, Timothy P; Frisbie, C Daniel

    2014-03-05

    Ion gels comprising ABA triblock copolymers and ionic liquids have received much attention as functional materials in numerous applications, especially as gate dielectrics in organic transistors. Here we have expanded the functionality of ion gels by demonstrating low-voltage, flexible electrochemiluminescent (ECL) devices using patterned ion gels containing redox-active luminophores. The ECL devices consisted only of a 30 μm thick emissive gel and two electrodes and were fabricated on indium tin oxide-coated substrates (e.g., polyester) simply by solution-casting the ECL gel and brush-painting a top Ag electrode. The triblock copolymer employed in the gel was polystyrene-block-poly(methyl methacrylate)-block-polystyrene, where the solvophobic polystyrene end blocks associate into micellar cross-links in the versatile ionic liquid 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([EMI][TFSI]). An ECL gel containing ~6.25 wt % Ru(bpy)3Cl2 (relative to [EMI][TFSI]) as the luminophore turned on at an AC peak-to-peak voltage as low as 2.6 V (i.e., -1.3 to +1.3 V) and showed a relatively rapid response (sub-ms). The wavelength of maximum emission was 610 nm (red-orange). With the use of an iridium(III) complex, Ir(diFppy)2(bpy)PF6 [diFppy = 2-(2',4'-difluorophenyl)pyridine; bpy = 2,2'-bipyridyl], the emitting color was tuned to a maximum wavelength of 540 nm (green). Moreover, when a blended luminophore system containing a 60:40 mixture of Ru(bpy)3(2+) and Ir(diFppy)2(bpy)(+) was used in the emissive layer, the luminance of red-orange-colored light was enhanced by a factor of 2, which is explained by the generation of the additional excited state Ru(bpy)3(2+)* by a coreactant pathway with Ir(diFppy)2(bpy)(+)* in addition to the usual annihilation pathway. This is the first time that enhanced ECL has been achieved in ion gels (or ionic liquids) using a coreactant. Overall, the results indicate that ECL ion gels are attractive multifunctional materials for

  18. A highly sensitive multiplasmonic sensor using hyperbolic chiral sculptured thin films

    Science.gov (United States)

    Abbas, Farhat; Faryad, Muhammad

    2017-11-01

    Surface plasmon-polariton (SPP) waves guided by an interface of a metal and a hyperbolic chiral sculptured thin film (STF) were theoretically investigated for optical sensing of an analyte. The chiral STF was infiltrated with the analyte to be sensed, and the resulting change in the incidence angle of excitation of the SPP waves in the prism-coupled configuration was computed. The results indicated the potential of this configuration for a plasmonic sensor with sensitivity up to 6000 degrees per refractive index units of the infiltrating fluid in the angular investigation scheme, with multiple SPP waves of the same frequency but different phase speeds, spatial profiles, and sensitivities. The enhancement in the sensitivity is attributed to the high field strength of the SPP waves near the interface. A multiplasmonic sensor is advantageous because of its potential for higher confidence in the measurement of the same analyte.

  19. Highly polarization sensitive photodetectors based on quasi-1D titanium trisulfide (TiS3)

    Science.gov (United States)

    Liu, Sijie; Xiao, Wenbo; Zhong, Mianzeng; Pan, Longfei; Wang, Xiaoting; Deng, Hui-Xiong; Liu, Jian; Li, Jingbo; Wei, Zhongming

    2018-05-01

    Photodetectors with high polarization sensitivity are in great demand in advanced optical communication. Here, we demonstrate that photodetectors based on titanium trisulfide (TiS3) are extremely sensitive to polarized light (from visible to the infrared), due to its reduced in-plane structural symmetry. By density functional theory calculation, TiS3 has a direct bandgap of 1.13 eV. The highest photoresponsivity reaches 2500 A W-1. What is more, in-plane optical selection caused by strong anisotropy leads to the photoresponsivity ratio for different directions of polarization that can reach 4:1. The angle-dependent photocurrents of TiS3 clearly display strong linear dichroism. Moreover, the Raman peak at 370 cm-1 is also very sensitive to the polarization direction. The theoretical optical absorption of TiS3 is calculated by using the HSE06 hybrid functional method, in qualitative agreement with the observed experimental photoresponsivity.

  20. A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers

    Energy Technology Data Exchange (ETDEWEB)

    Avonto, Cristina; Chittiboyina, Amar G. [National Center for Natural Products Research, Research Institute of Pharmaceutical Sciences, School of Pharmacy, The University of Mississippi, University, MS 38677 (United States); Rua, Diego [The Center for Food Safety and Applied Nutrition, US Food and Drug Administration, College Park, MD 20740 (United States); Khan, Ikhlas A., E-mail: ikhan@olemiss.edu [National Center for Natural Products Research, Research Institute of Pharmaceutical Sciences, School of Pharmacy, The University of Mississippi, University, MS 38677 (United States); Division of Pharmacognosy, Department of BioMolecular Sciences, School of Pharmacy, The University of Mississippi, University, MS 38677 (United States)

    2015-12-01

    Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles after incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, ‘HTS-DCYA assay’, is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens™ were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first time. - Highlights: • A novel fluorescence-based method to detect electrophilic sensitizers is proposed. • A model fluorescent thiol was used to directly quantify the reaction products. • A discussion of the reaction workflow

  1. A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers

    International Nuclear Information System (INIS)

    Avonto, Cristina; Chittiboyina, Amar G.; Rua, Diego; Khan, Ikhlas A.

    2015-01-01

    Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles after incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, ‘HTS-DCYA assay’, is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens™ were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first time. - Highlights: • A novel fluorescence-based method to detect electrophilic sensitizers is proposed. • A model fluorescent thiol was used to directly quantify the reaction products. • A discussion of the reaction workflow

  2. Electrochemical polarization behavior of sensitized SUS 304 stainless steel in high temperature water

    Energy Technology Data Exchange (ETDEWEB)

    Kushiya, K [Tohoku Univ., Sendai (Japan); Sugimoto, K; Ejima, T

    1978-11-01

    Anodic polarization curves for a solution-treated or sensitized SUS 304 stainless steel and solution-treated Fe-Ni-Cr ternary alloys containing 10%Ni and 6 to 14%Cr have been measured in deaerated 0.5 mol/l Na/sub 2/SO/sub 4/ solutions of pH 2.0 to 5.9 at 298, 523 and 553 K. Corrosion potentials for U-bend SCC test specimens of sensitized SUS 304 stainless steel have also been monitored for a long time in the same solutions as those used for the polarization measurements except that they were aerated. It was found that the differences in the current densities in the passive state, i sub(pass), between the solution treated steel and the sensitized one and also between the ternary alloy with higher Cr content and the one with lower Cr content become large with increasing temperature and decreasing pH. This means that the difference in the values of i sub(pass) between grain bodies and Cr-depleted zones along grain boundaries of sensitized steel becomes larger and susceptibility to intergranular corrosion of the sensitized steel in the passivation region becomes higher with increasing temperature and decreasing pH. Since corrosion potentials for the U-bend SCC test specimens in air-satulated solutions lie in the passive region of anodic polarization curves for the sensitized steel in deaerated solutions, the intergranular stress-corrosion cracking of the sensitized steel in high temperature water with dissolved oxygen is considered to be caused by the preferential corrosion in the Cr-depleted zone.

  3. Enhanced electrochemiluminescence quenching of CdS:Mn nanocrystals by CdTe QDs-doped silica nanoparticles for ultrasensitive detection of thrombin

    Science.gov (United States)

    Shan, Yun; Xu, Jing-Juan; Chen, Hong-Yuan

    2011-07-01

    This work reports an aptasensor for ultrasensitive detection of thrombin based on remarkably efficient energy-transfer induced electrochemiluminescence (ECL) quenching from CdS:Mn nanocrystals (NCs) film to CdTe QDs-doped silica nanoparticles (CdTe/SiO2 NPs). CdTe/SiO2 NPs were synthesized via the Stöber method and showed black bodies' strong absorption in a wide spectral range without excitonic emission, which made them excellent ECL quenchers. Within the effective distance of energy scavenging, the ECL quenching efficiency was dependent on the number of CdTe QDs doped into the silica NPs. Using ca. 200 CdTe QDs doped silica NPs on average of 40 nm in diameter as ECL quenching labels, attomolar detection of thrombin was successfully realized. The protein detection involves a competition binding event, based on thrombin replacing CdTe/SiO2 NPs labeled probing DNA which is hybridized with capturing aptamer immobilized on a CdS:Mn NCs film modified glassy carbon electrode surface by specific aptamer-protein affinity interactions. It results in the displacement of ECL quenching labels from CdS:Mn NCs film and concomitant ECL signal recovery. Owing to the high-content CdTe QDs in silica NP, the increment of ECL intensity (ΔIECL) and the concentration of thrombin showed a double logarithmic linear correlation in the range of 5.0 aM~5.0 fM with a detection limit of 1aM. And, the aptasensor hardly responded to antibody, bovine serum albumin (BSA), haemoglobin (Hb) and lysozyme, showing good detection selectivity for thrombin. This long-distance energy scavenging could have a promising application perspective in the detection of biological recognition events on a molecular level.This work reports an aptasensor for ultrasensitive detection of thrombin based on remarkably efficient energy-transfer induced electrochemiluminescence (ECL) quenching from CdS:Mn nanocrystals (NCs) film to CdTe QDs-doped silica nanoparticles (CdTe/SiO2 NPs). CdTe/SiO2 NPs were synthesized via

  4. Flexible, highly sensitive pressure sensor with a wide range based on graphene-silk network structure

    Science.gov (United States)

    Liu, Ying; Tao, Lu-Qi; Wang, Dan-Yang; Zhang, Tian-Yu; Yang, Yi; Ren, Tian-Ling

    2017-03-01

    In this paper, a flexible, simple-preparation, and low-cost graphene-silk pressure sensor based on soft silk substrate through thermal reduction was demonstrated. Taking silk as the support body, the device had formed a three-dimensional structure with ordered multi-layer structure. Through a simple and low-cost process technology, graphene-silk pressure sensor can achieve the sensitivity value of 0.4 kPa - 1 , and the measurement range can be as high as 140 kPa. Besides, pressure sensor can have a good combination with knitted clothing and textile product. The signal had good reproducibility in response to different pressures. Furthermore, graphene-silk pressure sensor can not only detect pressure higher than 100 kPa, but also can measure weak body signals. The characteristics of high-sensitivity, good repeatability, flexibility, and comfort for skin provide the high possibility to fit on various wearable electronics.

  5. Spectral and Concentration Sensitivity of Multijunction Solar Cells at High Temperature: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, Daniel J.; Steiner, Myles A.; Perl, Emmett E.; Simon, John

    2017-06-14

    We model the performance of two-junction solar cells at very high temperatures of ~400 degrees C and beyond for applications such as hybrid PV/solar-thermal power production, and identify areas in which the design and performance characteristics behave significantly differently than at more conventional near-room-temperature operating conditions. We show that high-temperature operation reduces the sensitivity of the cell efficiency to spectral content, but increases the sensitivity to concentration, both of which have implications for energy yield in terrestrial PV applications. For other high-temperature applications such as near-sun space missions, our findings indicate that concentration may be a useful tool to enhance cell efficiency.

  6. Highly sensitive wearable strain sensor based on silver nanowires and nanoparticles

    Science.gov (United States)

    Shengbo, Sang; Lihua, Liu; Aoqun, Jian; Qianqian, Duan; Jianlong, Ji; Qiang, Zhang; Wendong, Zhang

    2018-06-01

    Here, we propose a highly sensitive and stretchable strain sensor based on silver nanoparticles and nanowires (Ag NPs and NWs), advancing the rapid development of electronic skin. To improve the sensitivity of strain sensors based on silver nanowires (Ag NWs), Ag NPs and NWs were added to polydimethylsiloxane (PDMS) as an aid filler. Silver nanoparticles (Ag NPs) increase the conductive paths for electrons, leading to the low resistance of the resulting sensor (14.9 Ω). The strain sensor based on Ag NPs and NWs showed strong piezoresistivity with a tunable gauge factor (GF) at 3766, and a change in resistance as the strain linearly increased from 0% to 28.1%. The high GF demonstrates the irreplaceable role of Ag NPs in the sensor. Moreover, the applicability of our high-performance strain sensor has been demonstrated by its ability to sense movements caused by human talking, finger bending, wrist raising and walking.

  7. Highly sensitive chemiluminescent point mutation detection by circular strand-displacement amplification reaction.

    Science.gov (United States)

    Shi, Chao; Ge, Yujie; Gu, Hongxi; Ma, Cuiping

    2011-08-15

    Single nucleotide polymorphism (SNP) genotyping is attracting extensive attentions owing to its direct connections with human diseases including cancers. Here, we have developed a highly sensitive chemiluminescence biosensor based on circular strand-displacement amplification and the separation by magnetic beads reducing the background signal for point mutation detection at room temperature. This method took advantage of both the T4 DNA ligase recognizing single-base mismatch with high selectivity and the strand-displacement reaction of polymerase to perform signal amplification. The detection limit of this method was 1.3 × 10(-16)M, which showed better sensitivity than that of most of those reported detection methods of SNP. Additionally, the magnetic beads as carrier of immobility was not only to reduce the background signal, but also may have potential apply in high through-put screening of SNP detection in human genome. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Highly Sensitive and Selective Gas Sensor Using Hydrophilic and Hydrophobic Graphenes

    Science.gov (United States)

    Some, Surajit; Xu, Yang; Kim, Youngmin; Yoon, Yeoheung; Qin, Hongyi; Kulkarni, Atul; Kim, Taesung; Lee, Hyoyoung

    2013-01-01

    New hydrophilic 2D graphene oxide (GO) nanosheets with various oxygen functional groups were employed to maintain high sensitivity in highly unfavorable environments (extremely high humidity, strong acidic or basic). Novel one-headed polymer optical fiber sensor arrays using hydrophilic GO and hydrophobic reduced graphene oxide (rGO) were carefully designed, leading to the selective sensing of volatile organic gases for the first time. The two physically different surfaces of GO and rGO could provide the sensing ability to distinguish between tetrahydrofuran (THF) and dichloromethane (MC), respectively, which is the most challenging issue in the area of gas sensors. The eco-friendly physical properties of GO allowed for faster sensing and higher sensitivity when compared to previous results for rGO even under extreme environments of over 90% humidity, making it the best choice for an environmentally friendly gas sensor. PMID:23736838

  9. A Monolithic CMOS Magnetic Hall Sensor with High Sensitivity and Linearity Characteristics.

    Science.gov (United States)

    Huang, Haiyun; Wang, Dejun; Xu, Yue

    2015-10-27

    This paper presents a fully integrated linear Hall sensor by means of 0.8 μm high voltage complementary metal-oxide semiconductor (CMOS) technology. This monolithic Hall sensor chip features a highly sensitive horizontal switched Hall plate and an efficient signal conditioner using dynamic offset cancellation technique. An improved cross-like Hall plate achieves high magnetic sensitivity and low offset. A new spinning current modulator stabilizes the quiescent output voltage and improves the reliability of the signal conditioner. The tested results show that at the 5 V supply voltage, the maximum Hall output voltage of the monolithic Hall sensor microsystem, is up to ±2.1 V and the linearity of Hall output voltage is higher than 99% in the magnetic flux density range from ±5 mT to ±175 mT. The output equivalent residual offset is 0.48 mT and the static power consumption is 20 mW.

  10. Compton imaging with a highly-segmented, position-sensitive HPGe detector

    Energy Technology Data Exchange (ETDEWEB)

    Steinbach, T.; Hirsch, R.; Reiter, P.; Birkenbach, B.; Bruyneel, B.; Eberth, J.; Hess, H.; Lewandowski, L. [Universitaet zu Koeln, Institut fuer Kernphysik, Koeln (Germany); Gernhaeuser, R.; Maier, L.; Schlarb, M.; Weiler, B.; Winkel, M. [Technische Universitaet Muenchen, Physik Department, Garching (Germany)

    2017-02-15

    A Compton camera based on a highly-segmented high-purity germanium (HPGe) detector and a double-sided silicon-strip detector (DSSD) was developed, tested, and put into operation; the origin of γ radiation was determined successfully. The Compton camera is operated in two different modes. Coincidences from Compton-scattered γ-ray events between DSSD and HPGe detector allow for best angular resolution; while the high-efficiency mode takes advantage of the position sensitivity of the highly-segmented HPGe detector. In this mode the setup is sensitive to the whole 4π solid angle. The interaction-point positions in the 36-fold segmented large-volume HPGe detector are determined by pulse-shape analysis (PSA) of all HPGe detector signals. Imaging algorithms were developed for each mode and successfully implemented. The angular resolution sensitively depends on parameters such as geometry, selected multiplicity and interaction-point distances. Best results were obtained taking into account the crosstalk properties, the time alignment of the signals and the distance metric for the PSA for both operation modes. An angular resolution between 13.8 {sup circle} and 19.1 {sup circle}, depending on the minimal interaction-point distance for the high-efficiency mode at an energy of 1275 keV, was achieved. In the coincidence mode, an increased angular resolution of 4.6 {sup circle} was determined for the same γ-ray energy. (orig.)

  11. A Microneedle Functionalized with Polyethyleneimine and Nanotubes for Highly Sensitive, Label-Free Quantification of DNA.

    Science.gov (United States)

    Saadat-Moghaddam, Darius; Kim, Jong-Hoon

    2017-08-16

    The accurate measure of DNA concentration is necessary for many DNA-based biological applications. However, the current methods are limited in terms of sensitivity, reproducibility, human error, and contamination. Here, we present a microneedle functionalized with polyethyleneimine (PEI) and single-walled carbon nanotubes (SWCNTs) for the highly sensitive quantification of DNA. The microneedle was fabricated using ultraviolet (UV) lithography and anisotropic etching, and then functionalized with PEI and SWCNTs through a dip coating process. The electrical characteristics of the microneedle change with the accumulation of DNA on the surface. Current-voltage measurements in deionized water were conducted to study these changes in the electrical properties of the sensor. The sensitivity test found the signal to be discernable from the noise level down to 100 attomolar (aM), demonstrating higher sensitivity than currently available UV fluorescence and UV absorbance based methods. A microneedle without any surface modification only had a 100 femtomolar (fM) sensitivity. All measurement results were consistent with fluorescence microscopy.

  12. Development of a high-count-rate neutron detector with position sensitivity and high efficiency

    International Nuclear Information System (INIS)

    Nelson, R.; Sandoval, J.

    1996-01-01

    While the neutron scattering community is bombarded with hints of new technologies that may deliver detectors with high-count-rate capability, high efficiency, gamma-ray insensitivity, and high resolution across large areas, only the time-tested, gas-filled 3 He and scintillation detectors are in widespread use. Future spallation sources with higher fluxes simply must exploit some of the advanced detector schemes that are as yet unproved as production systems. Technologies indicating promise as neutron detectors include pixel arrays of amorphous silicon, silicon microstrips, microstrips with gas, and new scintillation materials. This project sought to study the competing neutron detector technologies and determine which or what combination will lead to a production detector system well suited for use at a high-intensity neutron scattering source

  13. Characterization of a high resolution and high sensitivity pre-clinical PET scanner with 3D event reconstruction

    CERN Document Server

    Rissi, M; Bolle, E; Dorholt, O; Hines, K E; Rohne, O; Skretting, A; Stapnes, S; Volgyes, D

    2012-01-01

    COMPET is a preclinical PET scanner aiming towards a high sensitivity, a high resolution and MRI compatibility by implementing a novel detector geometry. In this approach, long scintillating LYSO crystals are used to absorb the gamma-rays. To determine the point of interaction (P01) between gamma-ray and crystal, the light exiting the crystals on one of the long sides is collected with wavelength shifters (WLS) perpendicularly arranged to the crystals. This concept has two main advantages: (1) The parallax error is reduced to a minimum and is equal for the whole field of view (FOV). (2) The P01 and its energy deposit is known in all three dimension with a high resolution, allowing for the reconstruction of Compton scattered gamma-rays. Point (1) leads to a uniform point source resolution (PSR) distribution over the whole FOV, and also allows to place the detector close to the object being imaged. Both points (1) and (2) lead to an increased sensitivity and allow for both high resolution and sensitivity at the...

  14. Highly Sensitive Reentrant Cavity-Microstrip Patch Antenna Integrated Wireless Passive Pressure Sensor for High Temperature Applications

    Directory of Open Access Journals (Sweden)

    Fei Lu

    2017-01-01

    Full Text Available A novel reentrant cavity-microstrip patch antenna integrated wireless passive pressure sensor was proposed in this paper for high temperature applications. The reentrant cavity was analyzed from aspects of distributed model and equivalent lumped circuit model, on the basis of which an optimal sensor structure integrated with a rectangular microstrip patch antenna was proposed to better transmit/receive wireless signals. In this paper, the proposed sensor was fabricated with high temperature resistant alumina ceramic and silver metalization with weld sealing, and it was measured in a hermetic metal tank with nitrogen pressure loading. It was verified that the sensor was highly sensitive, keeping stable performance up to 300 kPa with an average sensitivity of 981.8 kHz/kPa at temperature 25°C, while, for high temperature measurement, the sensor can operate properly under pressure of 60–120 kPa in the temperature range of 25–300°C with maximum pressure sensitivity of 179.2 kHz/kPa. In practical application, the proposed sensor is used in a method called table lookup with a maximum error of 5.78%.

  15. High-sensitivity high-selectivity detection of CWAs and TICs using tunable laser photoacoustic spectroscopy

    Science.gov (United States)

    Pushkarsky, Michael; Webber, Michael; Patel, C. Kumar N.

    2005-03-01

    We provide a general technique for evaluating the performance of an optical sensor for the detection of chemical warfare agents (CWAs) in realistic environments and present data from a simulation model based on a field deployed discretely tunable 13CO2 laser photoacoustic spectrometer (L-PAS). Results of our calculations show the sensor performance in terms of usable sensor sensitivity as a function of probability of false positives (PFP). The false positives arise from the presence of many other gases in the ambient air that could be interferents. Using the L-PAS as it exists today, we can achieve a detection threshold of about 4 ppb for the CWAs while maintaining a PFP of less than 1:106. Our simulation permits us to vary a number of parameters in the model to provide guidance for performance improvement. We find that by using a larger density of laser lines (such as those obtained through the use of tunable semiconductor lasers), improving the detector noise and maintaining the accuracy of laser frequency determination, optical detection schemes can make possible CWA sensors having sub-ppb detection capability with TIC detection.

  16. Enhanced electrochemiluminescence quenching of CdS:Mn nanocrystals by CdTe QDs-doped silica nanoparticles for ultrasensitive detection of thrombin.

    Science.gov (United States)

    Shan, Yun; Xu, Jing-Juan; Chen, Hong-Yuan

    2011-07-01

    This work reports an aptasensor for ultrasensitive detection of thrombin based on remarkably efficient energy-transfer induced electrochemiluminescence (ECL) quenching from CdS:Mn nanocrystals (NCs) film to CdTe QDs-doped silica nanoparticles (CdTe/SiO(2) NPs). CdTe/SiO(2) NPs were synthesized via the Stöber method and showed black bodies' strong absorption in a wide spectral range without excitonic emission, which made them excellent ECL quenchers. Within the effective distance of energy scavenging, the ECL quenching efficiency was dependent on the number of CdTe QDs doped into the silica NPs. Using ca. 200 CdTe QDs doped silica NPs on average of 40 nm in diameter as ECL quenching labels, attomolar detection of thrombin was successfully realized. The protein detection involves a competition binding event, based on thrombin replacing CdTe/SiO(2) NPs labeled probing DNA which is hybridized with capturing aptamer immobilized on a CdS:Mn NCs film modified glassy carbon electrode surface by specific aptamer-protein affinity interactions. It results in the displacement of ECL quenching labels from CdS:Mn NCs film and concomitant ECL signal recovery. Owing to the high-content CdTe QDs in silica NP, the increment of ECL intensity (ΔI(ECL)) and the concentration of thrombin showed a double logarithmic linear correlation in the range of 5.0 aM∼5.0 fM with a detection limit of 1aM. And, the aptasensor hardly responded to antibody, bovine serum albumin (BSA), haemoglobin (Hb) and lysozyme, showing good detection selectivity for thrombin. This long-distance energy scavenging could have a promising application perspective in the detection of biological recognition events on a molecular level.

  17. One-step immobilization of tris(2,2'-bipyridyl)ruthenium(II) via vapor-surface sol-gel deposition towards solid-state electrochemiluminescence detection

    International Nuclear Information System (INIS)

    Qian Lei; Yang Xiurong

    2008-01-01

    A novel method for immobilization of tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy) 3 Cl 2 ) on electrode surfaces based on the vapor-surface sol-gel deposition strategy is first demonstrated in this paper. Ru(bpy) 3 Cl 2 immobilized sol-gel (Ru(bpy) 3 Cl 2 /sol-gel) films were characterized by UV-vis spectroscopy and field-emitted scanning electron microscopy (FE-SEM). These results showed that Ru(bpy) 3 Cl 2 was successfully incorporated into the silica sol-gel film. It was found that many irregular Ru(bpy) 3 Cl 2 /sol-gel clusters were formed on surfaces through one deposition and thick sol-gel films were observed after further deposition. Electrochemical properties and electrochemiluminescence (ECL) behaviors of Ru(bpy) 3 Cl 2 /sol-gel films could be easily adjusted by deposition numbers and time. At last, the Ru(bpy) 3 Cl 2 /sol-gel film modified electrode was used for solid-state ECL detection of tripropylamine. The linear range was from 5.8 x 10 -8 to 2.4 x 10 -4 M with the detection limit of 5 nM, which was three orders of magnitude lower than that from pure Nafion-modified electrodes. The ECL sensor also exhibited high stability, and still remained 92% response after being stored in air for 35 days. This method for immobilization of Ru(bpy) 3 Cl 2 is simple, convenient and low-cost relative to others, so it shows promising applications in solid-state ECL detection

  18. A highly sensitive pressure sensor using a Au-patterned polydimethylsiloxane membrane for biosensing applications

    International Nuclear Information System (INIS)

    Liu, Xinchuan; Zhu, Yihao; Nomani, Md W; Koley, Goutam; Wen, Xuejun; Hsia, Tain-Yen

    2013-01-01

    We report on the fabrication and characterization of a highly sensitive pressure sensor using a Au film patterned on a polydimethylsiloxane (PDMS) membrane. The strain-induced change in the film resistance was utilized to perform the quantitative measurement of absolute pressure. The highest sensitivity obtained for a 200 µm thick PDMS film sensor was 0.23/KPa with a range of 50 mm Hg, which is the best result reported so far, over that range, for any pressure sensor on a flexible membrane. The noise-limited pressure resolution was found to be 0.9 Pa (0.007 mm Hg), and a response time of ∼200 ms, are the best reported results for these sensors. The ultrahigh sensitivity is attributed to the strain-induced formation of microcracks, the effect of which on the resistance change was found to be highly reversible within a certain pressure range. A physical model correlating the sensitivity with the sensor parameters and crack geometry has been proposed. (paper)

  19. Quality and sensitivity of high-resolution numerical simulation of urban heat islands

    Science.gov (United States)

    Li, Dan; Bou-Zeid, Elie

    2014-05-01

    High-resolution numerical simulations of the urban heat island (UHI) effect with the widely-used Weather Research and Forecasting (WRF) model are assessed. Both the sensitivity of the results to the simulation setup, and the quality of the simulated fields as representations of the real world, are investigated. Results indicate that the WRF-simulated surface temperatures are more sensitive to the planetary boundary layer (PBL) scheme choice during nighttime, and more sensitive to the surface thermal roughness length parameterization during daytime. The urban surface temperatures simulated by WRF are also highly sensitive to the urban canopy model (UCM) used. The implementation in this study of an improved UCM (the Princeton UCM or PUCM) that allows the simulation of heterogeneous urban facets and of key hydrological processes, together with the so-called CZ09 parameterization for the thermal roughness length, significantly reduce the bias (Changing UCMs and PBL schemes does not alter the performance of WRF in reproducing bulk boundary layer temperature profiles significantly. The results illustrate the wide range of urban environmental conditions that various configurations of WRF can produce, and the significant biases that should be assessed before inferences are made based on WRF outputs. The optimal set-up of WRF-PUCM developed in this paper also paves the way for a confident exploration of the city-scale impacts of UHI mitigation strategies in the companion paper (Li et al 2014).

  20. High hunger state increases olfactory sensitivity to neutral but not food odors.

    Science.gov (United States)

    Stafford, Lorenzo D; Welbeck, Kimberley

    2011-01-01

    Understanding how hunger state relates to olfactory sensitivity has become more urgent due to their possible role in obesity. In 2 studies (within-subjects: n = 24, between-subjects: n = 40), participants were provided with lunch before (satiated state) or after (nonsatiated state) testing and completed a standardized olfactory threshold test to a neutral odor (Experiments 1 and 2) and discrimination test to a food odor (Experiment 2). Experiment 1 revealed that olfactory sensitivity was greater in the nonsatiated versus satiated state, with additionally increased sensitivity for the low body mass index (BMI) compared with high BMI group. Experiment 2 replicated this effect for neutral odors, but in the case of food odors, those in a satiated state had greater acuity. Additionally, whereas the high BMI group had higher acuity to food odors in the satiated versus nonsatiated state, no such differences were found for the low BMI group. The research here is the first to demonstrate how olfactory acuity changes as a function of hunger state and relatedness of odor to food and that BMI can predict differences in olfactory sensitivity.

  1. Corrosion Behavior of the Stressed Sensitized Austenitic Stainless Steels of High Nitrogen Content in Seawater

    Directory of Open Access Journals (Sweden)

    A. Almubarak

    2013-01-01

    Full Text Available The purpose of this paper is to study the effect of high nitrogen content on corrosion behavior of austenitic stainless steels in seawater under severe conditions such as tensile stresses and existence of sensitization in the structure. A constant tensile stress has been applied to sensitized specimens types 304, 316L, 304LN, 304NH, and 316NH stainless steels. Microstructure investigation revealed various degrees of stress corrosion cracking. SCC was severe in type 304, moderate in types 316L and 304LN, and very slight in types 304NH and 316NH. The electrochemical polarization curves showed an obvious second current peak for the sensitized alloys which indicated the existence of second phase in the structure and the presence of intergranular stress corrosion cracking. EPR test provided a rapid and efficient nondestructive testing method for showing passivity, degree of sensitization and determining IGSCC for stainless steels in seawater. A significant conclusion was obtained that austenitic stainless steels of high nitrogen content corrode at a much slower rate increase pitting resistance and offer an excellent resistance to stress corrosion cracking in seawater.

  2. High Sensitive pH Sensor Based on AlInN/GaN Heterostructure Transistor.

    Science.gov (United States)

    Dong, Yan; Son, Dong-Hyeok; Dai, Quan; Lee, Jun-Hyeok; Won, Chul-Ho; Kim, Jeong-Gil; Chen, Dunjun; Lee, Jung-Hee; Lu, Hai; Zhang, Rong; Zheng, Youdou

    2018-04-24

    The AlInN/GaN high-electron-mobility-transistor (HEMT) indicates better performances compared with the traditional AlGaN/GaN HEMTs. The present work investigated the pH sensor functionality of an analogous HEMT AlInN/GaN device with an open gate. It was shown that the Al 0.83 In 0.17 N/GaN device demonstrates excellent pH sense functionality in aqueous solutions, exhibiting higher sensitivity (−30.83 μA/pH for AlInN/GaN and −4.6 μA/pH for AlGaN/GaN) and a faster response time, lower degradation and good stability with respect to the AlGaN/GaN device, which is attributed to higher two-dimensional electron gas (2DEG) density and a thinner barrier layer in Al 0.83 In 0.17 N/GaN owning to lattice matching. On the other hand, the open gate geometry was found to affect the pH sensitivity obviously. Properly increasing the width and shortening the length of the open gate area could enhance the sensitivity. However, when the open gate width is too larger or too small, the pH sensitivity would be suppressed conversely. Designing an optimal ratio of the width to the length is important for achieving high sensitivity. This work suggests that the AlInN/GaN-based 2DEG carrier modulated devices would be good candidates for high-performance pH sensors and other related applications.

  3. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    International Nuclear Information System (INIS)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng

    2014-01-01

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β 2 -agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β 2 -agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β 2 -agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β 2 -agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL −1 , with the detection limits of 0.20 and 0.040 ng mL −1 (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β 2 -agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety

  4. High Sensitive pH Sensor Based on AlInN/GaN Heterostructure Transistor

    Directory of Open Access Journals (Sweden)

    Yan Dong

    2018-04-01

    Full Text Available The AlInN/GaN high-electron-mobility-transistor (HEMT indicates better performances compared with the traditional AlGaN/GaN HEMTs. The present work investigated the pH sensor functionality of an analogous HEMT AlInN/GaN device with an open gate. It was shown that the Al0.83In0.17N/GaN device demonstrates excellent pH sense functionality in aqueous solutions, exhibiting higher sensitivity (−30.83 μA/pH for AlInN/GaN and −4.6 μA/pH for AlGaN/GaN and a faster response time, lower degradation and good stability with respect to the AlGaN/GaN device, which is attributed to higher two-dimensional electron gas (2DEG density and a thinner barrier layer in Al0.83In0.17N/GaN owning to lattice matching. On the other hand, the open gate geometry was found to affect the pH sensitivity obviously. Properly increasing the width and shortening the length of the open gate area could enhance the sensitivity. However, when the open gate width is too larger or too small, the pH sensitivity would be suppressed conversely. Designing an optimal ratio of the width to the length is important for achieving high sensitivity. This work suggests that the AlInN/GaN-based 2DEG carrier modulated devices would be good candidates for high-performance pH sensors and other related applications.

  5. Sensitizing effects of NOx on CH4 oxidation at high pressure

    DEFF Research Database (Denmark)

    Rasmussen, Christian Lund; Rasmussen, Anja Egede; Glarborg, Peter

    2008-01-01

    The CH4/O2/NOx system is investigated in a laboratory-scale high pressure laminar flow reactor with the purpose of elucidating the sensitizing effects of NOx on CH4 oxidation at high pressures and medium temperatures. Experiments are conducted at 100, 50, and 20 bar, 600-900 K, and stoichiometric...... ratios ranging from highly reducing to oxidizing conditions. The experimental results are interpreted in terms of a detailed kinetic model drawn from previous work of the authors, including an updated reaction subset for the direct interactions of NOx and C1-2 hydrocarbon species relevant...

  6. High-Efficiency Dye-Sensitized Solar Cell with Three-Dimensional Photoanode

    KAUST Repository

    Tétreault, Nicolas

    2011-11-09

    Herein, we present a straightforward bottom-up synthesis of a high electron mobility and highly light scattering macroporous photoanode for dye-sensitized solar cells. The dense three-dimensional Al/ZnO, SnO2, or TiO 2 host integrates a conformal passivation thin film to reduce recombination and a large surface-area mesoporous anatase guest for high dye loading. This novel photoanode is designed to improve the charge extraction resulting in higher fill factor and photovoltage for DSCs. An increase in photovoltage of up to 110 mV over state-of-the-art DSC is demonstrated. © 2011 American Chemical Society.

  7. High-Efficiency Dye-Sensitized Solar Cell with Three-Dimensional Photoanode

    KAUST Repository

    Té treault, Nicolas; Arsenault, É ric; Heiniger, Leo-Philipp; Soheilnia, Navid; Brillet, Jé ré mie; Moehl, Thomas; Zakeeruddin, Shaik; Ozin, Geoffrey A.; Grä tzel, Michael

    2011-01-01

    Herein, we present a straightforward bottom-up synthesis of a high electron mobility and highly light scattering macroporous photoanode for dye-sensitized solar cells. The dense three-dimensional Al/ZnO, SnO2, or TiO 2 host integrates a conformal passivation thin film to reduce recombination and a large surface-area mesoporous anatase guest for high dye loading. This novel photoanode is designed to improve the charge extraction resulting in higher fill factor and photovoltage for DSCs. An increase in photovoltage of up to 110 mV over state-of-the-art DSC is demonstrated. © 2011 American Chemical Society.

  8. Scrambled eggs: A highly sensitive molecular diagnostic workflow for Fasciola species specific detection from faecal samples

    Science.gov (United States)

    Calvani, Nichola Eliza Davies; Windsor, Peter Andrew; Bush, Russell David

    2017-01-01

    Background Fasciolosis, due to Fasciola hepatica and Fasciola gigantica, is a re-emerging zoonotic parasitic disease of worldwide importance. Human and animal infections are commonly diagnosed by the traditional sedimentation and faecal egg-counting technique. However, this technique is time-consuming and prone to sensitivity errors when a large number of samples must be processed or if the operator lacks sufficient experience. Additionally, diagnosis can only be made once the 12-week pre-patent period has passed. Recently, a commercially available coprological antigen ELISA has enabled detection of F. hepatica prior to the completion of the pre-patent period, providing earlier diagnosis and increased throughput, although species differentiation is not possible in areas of parasite sympatry. Real-time PCR offers the combined benefits of highly sensitive species differentiation for medium to large sample sizes. However, no molecular diagnostic workflow currently exists for the identification of Fasciola spp. in faecal samples. Methodology/Principal findings A new molecular diagnostic workflow for the highly-sensitive detection and quantification of Fasciola spp. in faecal samples was developed. The technique involves sedimenting and pelleting the samples prior to DNA isolation in order to concentrate the eggs, followed by disruption by bead-beating in a benchtop homogeniser to ensure access to DNA. Although both the new molecular workflow and the traditional sedimentation technique were sensitive and specific, the new molecular workflow enabled faster sample throughput in medium to large epidemiological studies, and provided the additional benefit of speciation. Further, good correlation (R2 = 0.74–0.76) was observed between the real-time PCR values and the faecal egg count (FEC) using the new molecular workflow for all herds and sampling periods. Finally, no effect of storage in 70% ethanol was detected on sedimentation and DNA isolation outcomes; enabling

  9. Scrambled eggs: A highly sensitive molecular diagnostic workflow for Fasciola species specific detection from faecal samples.

    Directory of Open Access Journals (Sweden)

    Nichola Eliza Davies Calvani

    2017-09-01

    Full Text Available Fasciolosis, due to Fasciola hepatica and Fasciola gigantica, is a re-emerging zoonotic parasitic disease of worldwide importance. Human and animal infections are commonly diagnosed by the traditional sedimentation and faecal egg-counting technique. However, this technique is time-consuming and prone to sensitivity errors when a large number of samples must be processed or if the operator lacks sufficient experience. Additionally, diagnosis can only be made once the 12-week pre-patent period has passed. Recently, a commercially available coprological antigen ELISA has enabled detection of F. hepatica prior to the completion of the pre-patent period, providing earlier diagnosis and increased throughput, although species differentiation is not possible in areas of parasite sympatry. Real-time PCR offers the combined benefits of highly sensitive species differentiation for medium to large sample sizes. However, no molecular diagnostic workflow currently exists for the identification of Fasciola spp. in faecal samples.A new molecular diagnostic workflow for the highly-sensitive detection and quantification of Fasciola spp. in faecal samples was developed. The technique involves sedimenting and pelleting the samples prior to DNA isolation in order to concentrate the eggs, followed by disruption by bead-beating in a benchtop homogeniser to ensure access to DNA. Although both the new molecular workflow and the traditional sedimentation technique were sensitive and specific, the new molecular workflow enabled faster sample throughput in medium to large epidemiological studies, and provided the additional benefit of speciation. Further, good correlation (R2 = 0.74-0.76 was observed between the real-time PCR values and the faecal egg count (FEC using the new molecular workflow for all herds and sampling periods. Finally, no effect of storage in 70% ethanol was detected on sedimentation and DNA isolation outcomes; enabling transport of samples from endemic

  10. Scrambled eggs: A highly sensitive molecular diagnostic workflow for Fasciola species specific detection from faecal samples.

    Science.gov (United States)

    Calvani, Nichola Eliza Davies; Windsor, Peter Andrew; Bush, Russell David; Šlapeta, Jan

    2017-09-01

    Fasciolosis, due to Fasciola hepatica and Fasciola gigantica, is a re-emerging zoonotic parasitic disease of worldwide importance. Human and animal infections are commonly diagnosed by the traditional sedimentation and faecal egg-counting technique. However, this technique is time-consuming and prone to sensitivity errors when a large number of samples must be processed or if the operator lacks sufficient experience. Additionally, diagnosis can only be made once the 12-week pre-patent period has passed. Recently, a commercially available coprological antigen ELISA has enabled detection of F. hepatica prior to the completion of the pre-patent period, providing earlier diagnosis and increased throughput, although species differentiation is not possible in areas of parasite sympatry. Real-time PCR offers the combined benefits of highly sensitive species differentiation for medium to large sample sizes. However, no molecular diagnostic workflow currently exists for the identification of Fasciola spp. in faecal samples. A new molecular diagnostic workflow for the highly-sensitive detection and quantification of Fasciola spp. in faecal samples was developed. The technique involves sedimenting and pelleting the samples prior to DNA isolation in order to concentrate the eggs, followed by disruption by bead-beating in a benchtop homogeniser to ensure access to DNA. Although both the new molecular workflow and the traditional sedimentation technique were sensitive and specific, the new molecular workflow enabled faster sample throughput in medium to large epidemiological studies, and provided the additional benefit of speciation. Further, good correlation (R2 = 0.74-0.76) was observed between the real-time PCR values and the faecal egg count (FEC) using the new molecular workflow for all herds and sampling periods. Finally, no effect of storage in 70% ethanol was detected on sedimentation and DNA isolation outcomes; enabling transport of samples from endemic to non

  11. Using Satellites to Investigate the Sensitivity of Longwave Downward Radiation to Water Vapor at High Elevations

    Science.gov (United States)

    Naud, Catherine M.; Miller, James R.; Landry, Chris

    2012-01-01

    Many studies suggest that high-elevation regions may be among the most sensitive to future climate change. However, in situ observations in these often remote locations are too sparse to determine the feedbacks responsible for enhanced warming rates. One of these feedbacks is associated with the sensitivity of longwave downward radiation (LDR) to changes in water vapor, with the sensitivity being particularly large in many high-elevation regions where the average water vapor is often low. We show that satellite retrievals from the Moderate Resolution Imaging Spectroradiometer (MODIS) and Clouds and the Earth's Radiant Energy System (CERES) can be used to expand the current ground-based observational database and that the monthly averaged clear-sky satellite estimates of humidity and LDR are in good agreement with the well-instrumented Center for Snow and Avalanche Studies ground-based site in the southwestern Colorado Rocky Mountains. The relationship between MODIS-retrieved precipitable water vapor and surface specific humidity across the contiguous United States was found to be similar to that previously found for the Alps. More important, we show that satellites capture the nonlinear relationship between LDR and water vapor and confirm that LDR is especially sensitive to changes in water vapor at high elevations in several midlatitude mountain ranges. Because the global population depends on adequate fresh water, much of which has its source in high mountains, it is critically important to understand how climate will change there. We demonstrate that satellites can be used to investigate these feedbacks in high-elevation regions where the coverage of surface-based observations is insufficient to do so.

  12. Performance of high-resolution position-sensitive detectors developed for storage-ring decay experiments

    International Nuclear Information System (INIS)

    Yamaguchi, T.; Suzaki, F.; Izumikawa, T.; Miyazawa, S.; Morimoto, K.; Suzuki, T.; Tokanai, F.; Furuki, H.; Ichihashi, N.; Ichikawa, C.; Kitagawa, A.; Kuboki, T.; Momota, S.; Nagae, D.; Nagashima, M.; Nakamura, Y.; Nishikiori, R.; Niwa, T.; Ohtsubo, T.; Ozawa, A.

    2013-01-01

    Highlights: • Position-sensitive detectors were developed for storage-ring decay spectroscopy. • Fiber scintillation and silicon strip detectors were tested with heavy ion beams. • A new fiber scintillation detector showed an excellent position resolution. • Position and energy detection by silicon strip detectors enable full identification. -- Abstract: As next generation spectroscopic tools, heavy-ion cooler storage rings will be a unique application of highly charged RI beam experiments. Decay spectroscopy of highly charged rare isotopes provides us important information relevant to the stellar conditions, such as for the s- and r-process nucleosynthesis. In-ring decay products of highly charged RI will be momentum-analyzed and reach a position-sensitive detector set-up located outside of the storage orbit. To realize such in-ring decay experiments, we have developed and tested two types of high-resolution position-sensitive detectors: silicon strips and scintillating fibers. The beam test experiments resulted in excellent position resolutions for both detectors, which will be available for future storage-ring experiments

  13. High prevalence of heartburn and low acid sensitivity in patients with idiopathic achalasia.

    Science.gov (United States)

    Ponce, Julio; Ortiz, Vicente; Maroto, Nuria; Ponce, Marta; Bustamante, Marco; Garrigues, Vicente

    2011-03-01

    Heartburn is frequently reported by patients with achalasia before treatment. However, the esophageal sensitivity to acid as a possible mediator of this symptom has not been previously evaluated. To evaluate the prevalence of gastroesophageal reflux symptoms and the esophageal sensitivity to acid perfusion in patients with untreated achalasia. Forty patients with achalasia were prospectively evaluated. Forty-three patients with gastroesophageal reflux disease comprised the control group (ten of them with Barrett's esophagus). Symptoms were evaluated by a structured clinical questionnaire. Objective assessment was performed by ambulatory 24-h esophageal pH monitoring and endoscopy. Esophageal sensitivity to acid was evaluated by esophageal perfusion of ClH 0.1 N. Fifteen (37%) of the 40 patients with achalasia presented heartburn, but only four of them had esophagitis and/or abnormal esophageal pH recording. Eight patients had abnormal pH recording. Three patients had esophagitis. The esophagus was sensitive to acid in seven (17%) patients with achalasia, three of them with heartburn and one with abnormal pH recording. In the control group, 40 of 43 (93%) presented heartburn. Acid perfusion was positive in 32 (74%). Sensitivity to acid was lower in patients with achalasia than in those with gastroesophageal reflux disease with or without Barrett's esophagus. The prevalence of heartburn in patients with achalasia is high, although its association with objective indicators of gastroesophageal reflux disease is weak. Patients with achalasia have lower esophageal sensitivity to acid than patients with GERD, suggesting that heartburn is does not arise from this condition.

  14. Improved Diffuse Fluorescence Flow Cytometer Prototype for High Sensitivity Detection of Rare Circulating Cells In Vivo

    Science.gov (United States)

    Pestana, Noah Benjamin

    Accurate quantification of circulating cell populations is important in many areas of pre-clinical and clinical biomedical research, for example, in the study of cancer metastasis or the immune response following tissue and organ transplants. Normally this is done "ex-vivo" by drawing and purifying a small volume of blood and then analyzing it with flow cytometry, hemocytometry or microfludic devices, but the sensitivity of these techniques are poor and the process of handling samples has been shown to affect cell viability and behavior. More recently "in vivo flow cytometry" (IVFC) techniques have been developed where fluorescently-labeled cells flowing in a small blood vessel in the ear or retina are analyzed, but the sensitivity is generally poor due to the small sampling volume. To address this, our group recently developed a method known as "Diffuse Fluorescence Flow Cytometry" (DFFC) that allows detection and counting of rare circulating cells with diffuse photons, offering extremely high single cell counting sensitivity. In this thesis, an improved DFFC prototype was designed and validated. The chief improvements were three-fold, i) improved optical collection efficiency, ii) improved detection electronics, and iii) development of a method to mitigate motion artifacts during in vivo measurements. In combination, these improvements yielded an overall instrument detection sensitivity better than 1 cell/mL in vivo, which is the most sensitive IVFC system reported to date. Second, development and validation of a low-cost microfluidic device reader for analysis of ocular fluids is described. We demonstrate that this device has equivalent or better sensitivity and accuracy compared a fluorescence microscope, but at an order-of-magnitude reduced cost with simplified operation. Future improvements to both instruments are also discussed.

  15. New and highly sensitive assay for L-5-hydroxytryptophan decarboxylase activity by high-performance liquid chromatography-voltammetry.

    Science.gov (United States)

    Rahman, M K; Nagatsu, T; Kato, T

    1980-12-12

    This paper describes a new, inexpensive and highly sensitive assay for aromatic L-amino acid decarboxylase (AADC) activity, using L-5-hydroxytryptophan (L-5-HTP) as substrate, in rat and human brains and serum by high-performance liquid chromatography (HPLC) with voltammetric detection. L-5-HTP was used as substrate and D-5-HTP for the blank. After isolating serotonin (5-HT) formed enzymatically from L-5-HTP on a small Amberlite CG-50 column, the 5-HT was eluted with hydrochloric acid and assayed by HPLC with a voltammetric detector. N-Methyldopamine was added to each incubation mixture as an internal standard. This method is sensitive enough to measure 5-HT, formed by the enzyme, 100 fmol to 140 pmol or more. An advantage of this method is that one can incubate the enzyme for longer time (up to 150 min), as compared with AADC assay using L-DOPA as substrate, resulting in a very high sensitivity. By using this new method, AADC activity was discovered in rat serum.

  16. Highly Sensitive Bulk Silicon Chemical Sensors with Sub-5 nm Thin Charge Inversion Layers.

    Science.gov (United States)

    Fahad, Hossain M; Gupta, Niharika; Han, Rui; Desai, Sujay B; Javey, Ali

    2018-03-27

    There is an increasing demand for mass-producible, low-power gas sensors in a wide variety of industrial and consumer applications. Here, we report chemical-sensitive field-effect-transistors (CS-FETs) based on bulk silicon wafers, wherein an electrostatically confined sub-5 nm thin charge inversion layer is modulated by chemical exposure to achieve a high-sensitivity gas-sensing platform. Using hydrogen sensing as a "litmus" test, we demonstrate large sensor responses (>1000%) to 0.5% H 2 gas, with fast response (<60 s) and recovery times (<120 s) at room temperature and low power (<50 μW). On the basis of these performance metrics as well as standardized benchmarking, we show that bulk silicon CS-FETs offer similar or better sensing performance compared to emerging nanostructures semiconductors while providing a highly scalable and manufacturable platform.

  17. Silicon on-chip bandpass filters for the multiplexing of high sensitivity photonic crystal microcavity biosensors

    International Nuclear Information System (INIS)

    Yan, Hai; Zou, Yi; Yang, Chun-Ju; Chakravarty, Swapnajit; Wang, Zheng; Tang, Naimei; Chen, Ray T.; Fan, Donglei

    2015-01-01

    A method for the dense integration of high sensitivity photonic crystal (PC) waveguide based biosensors is proposed and experimentally demonstrated on a silicon platform. By connecting an additional PC waveguide filter to a PC microcavity sensor in series, a transmission passband is created, containing the resonances of the PC microcavity for sensing purpose. With proper engineering of the passband, multiple high sensitivity PC microcavity sensors can be integrated into microarrays and be interrogated simultaneously between a single input and a single output port. The concept was demonstrated with a 2-channel L55 PC biosensor array containing PC waveguide filters. The experiment showed that the sensors on both channels can be monitored simultaneously from a single output spectrum. Less than 3 dB extra loss for the additional PC waveguide filter is observed

  18. Development of a highly sensitive and specific immunoassay for enrofloxacin based on heterologous coating haptens.

    Science.gov (United States)

    Wang, Zhanhui; Zhang, Huiyan; Ni, Hengjia; Zhang, Suxia; Shen, Jianzhong

    2014-04-11

    In the paper, an enzyme-linked immunosorbent immunoassay (ELISA) for detection of enrofloxacin was described using one new derivative of enrofloxacin as coating hapten, resulting in surprisingly high sensitivity and specificity. Incorporation of aminobutyric acid (AA) in the new derivative of enrofloxacin had decreased the IC50 of the ELISA for enrofloxacin from 1.3 μg L(-1) to as low as 0.07 μg L(-1). The assay showed neglect cross-reactivity for other fluoroquinolones but ofloxacin (8.23%), marbofloxacin (8.97%) and pefloxacin (7.29%). Analysis of enrofloxacin fortified chicken muscle showed average recoveries from 81 to 115%. The high sensitivity and specificity of the assay makes it a suitable screening method for the determination of low levels of enrofloxacin in chicken muscle without clean-up step. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Silicon on-chip bandpass filters for the multiplexing of high sensitivity photonic crystal microcavity biosensors

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Hai, E-mail: hai.yan@utexas.edu; Zou, Yi; Yang, Chun-Ju [Department of Electrical and Computer Engineering, Microelectronics Research Center, The University of Texas at Austin, 10100 Burnet Rd., Austin, Texas 78758 (United States); Chakravarty, Swapnajit, E-mail: swapnajit.chakravarty@omegaoptics.com [Omega Optics, Inc., 8500 Shoal Creek Blvd., Austin, Texas 78757 (United States); Wang, Zheng [Department of Electrical and Computer Engineering, Microelectronics Research Center, The University of Texas at Austin, 10100 Burnet Rd., Austin, Texas 78758 (United States); Materials Science and Engineering Program, Texas Materials Institute, The University of Texas at Austin, Austin, Texas 78712 (United States); Tang, Naimei; Chen, Ray T., E-mail: raychen@uts.cc.utexas.edu [Department of Electrical and Computer Engineering, Microelectronics Research Center, The University of Texas at Austin, 10100 Burnet Rd., Austin, Texas 78758 (United States); Omega Optics, Inc., 8500 Shoal Creek Blvd., Austin, Texas 78757 (United States); Fan, Donglei [Materials Science and Engineering Program, Texas Materials Institute, The University of Texas at Austin, Austin, Texas 78712 (United States); Department of Mechanical Engineering, The University of Texas at Austin, Austin, Texas 78712 (United States)

    2015-03-23

    A method for the dense integration of high sensitivity photonic crystal (PC) waveguide based biosensors is proposed and experimentally demonstrated on a silicon platform. By connecting an additional PC waveguide filter to a PC microcavity sensor in series, a transmission passband is created, containing the resonances of the PC microcavity for sensing purpose. With proper engineering of the passband, multiple high sensitivity PC microcavity sensors can be integrated into microarrays and be interrogated simultaneously between a single input and a single output port. The concept was demonstrated with a 2-channel L55 PC biosensor array containing PC waveguide filters. The experiment showed that the sensors on both channels can be monitored simultaneously from a single output spectrum. Less than 3 dB extra loss for the additional PC waveguide filter is observed.

  20. Amorphous Silicon-Germanium Films with Embedded Nano crystals for Thermal Detectors with Very High Sensitivity

    International Nuclear Information System (INIS)

    Calleja, C.; Torres, A.; Rosales-Quintero, P.; Moreno, M.

    2016-01-01

    We have optimized the deposition conditions of amorphous silicon-germanium films with embedded nano crystals in a plasma enhanced chemical vapor deposition (PECVD) reactor, working at a standard frequency of 13.56 MHz. The objective was to produce films with very large Temperature Coefficient of Resistance (TCR), which is a signature of the sensitivity in thermal detectors (micro bolometers). Morphological, electrical, and optical characterization were performed in the films, and we found optimal conditions for obtaining films with very high values of thermal coefficient of resistance (TCR = 7.9%K -1 ). Our results show that amorphous silicon-germanium films with embedded nano crystals can be used as thermo sensitive films in high performance infrared focal plane arrays (IRFPAs) used in commercial thermal cameras.

  1. A highly sensitive fluorescent probe based on BODIPY for Hg2+ in aqueous solution

    Directory of Open Access Journals (Sweden)

    ZHAO Junwei

    2016-12-01

    Full Text Available A highly sensitive fluorescent probe based on BODIPY and hydrazine for Hg2+ was designed and synthesized.This probe could detect mercury ions in aqueous solutions within 5 min.With the increase of Hg2+ mole concentration,an obvious red shift of UV-Vis absorption wavelength was observed and the fluorescence intensity significantly enhanced.It was found that the fluorescence intensity of an aqueous solution containing 0.1 μmol/L Hg2+ is much stronger than that of blank solution,which indicats that the fluorescent probe has high sensitivity.In addition,other metal ions could not cause the change of fluorescent spectra,which means this probe has good selectivity,as well.

  2. Intra-Cavity Total Reflection For High Sensitivity Measurement Of Optical Properties

    Science.gov (United States)

    Pipino, Andrew Charles Rule

    1999-11-16

    An optical cavity resonator device is provided for conducting sensitive murement of optical absorption by matter in any state with diffraction-limited spatial resolution through utilization of total internal reflection within a high-Q (high quality, low loss) optical cavity. Intracavity total reflection generates an evanescent wave that decays exponentially in space at a point external to the cavity, thereby providing a localized region where absorbing materials can be sensitively probed through alteration of the Q-factor of the otherwise isolated cavity. When a laser pulse is injected into the cavity and passes through the evanescent state, an amplitude loss resulting from absorption is incurred that reduces the lifetime of the pulse in the cavity. By monitoring the decay of the injected pulse, the absorption coefficient of manner within the evanescent wave region is accurately obtained from the decay time measurement.

  3. Quartz crystal microbalance-based system for high-sensitivity differential sputter yield measurements

    International Nuclear Information System (INIS)

    Rubin, B.; Topper, J. L.; Farnell, C. C.; Yalin, A. P.

    2009-01-01

    We present a quartz crystal microbalance-based system for high sensitivity differential sputter yield measurements of different target materials due to ion bombardment. The differential sputter yields can be integrated to find total yields. Possible ion beam conditions include ion energies in the range of 30-350 eV and incidence angles of 0 deg. - 70 deg. from normal. A four-grid ion optics system is used to achieve a collimated ion beam at low energy (<100 eV) and a two-grid ion optics is used for higher energies (up to 750 eV). A complementary weight loss approach is also used to measure total sputter yields. Validation experiments are presented that confirm high sensitivity and accuracy of sputter yield measurements.

  4. Transitioning high sensitivity cardiac troponin I (hs-cTnI) into routine diagnostic use: More than just a sensitivity issue

    LENUS (Irish Health Repository)

    Lee, Graham R

    2016-04-01

    High sensitivity cardiac troponin T and I (hs-cTnT and hs-cTnI) assays show analytical, diagnostic and prognostic improvement over contemporary sensitive cTn assays. However, given the importance of troponin in the diagnosis of myocardial infarction, implementing this test requires rigorous analytical and clinical verification across the total testing pathway. This was the aim of this study.

  5. New synthesis of gold nanocorals using a diazonium compound, and their application to an electrochemiluminescent assay of hydrogen peroxide

    International Nuclear Information System (INIS)

    Xu, Min; Qi, Wenjing; Zhang, Ling; Lai, Jianping; Aziz-ur-Rehman; Majeed, Saadat; Xu, Guobao

    2014-01-01

    The reaction of hydrogen tetracholoroaurate, sodium borohydride and the diazonium compound prepared from 4-aminobenzoic acid results in the formation of gold nanocorals (Au-NCs) for the first time. Scanning electron microscopy images and transmission electron microscopy images show that the Au-NCs are composed of nanowires with a diameter of 5.3 nm. A glassy carbon electrode modified with Au-NCs is found to trigger intense electrochemiluminescence of the luminol/H 2 O 2 system at a potential of −0.13 V. The effect was exploited to determine H 2 O 2 in the 0.1 to 100 μM concentration range with a 30 nM detection limit. (author)

  6. A highly sensitive method for detection of molybdenum-containing proteins

    International Nuclear Information System (INIS)

    Kalakutskii, K.L.; Shvetsov, A.A.; Bursakov, S.A.; Letarov, A.V.; Zabolotnyi, A.I.; L'vov, N.P.

    1992-01-01

    A highly sensitive method for detection of molybdenum-containing proteins in gels after electrophoresis has been developed. The method involves in vitro labeling of the proteins with the radioactive isotope 185 W. The method used to detect molybdenum-accumulating proteins in lupine seeds, xanthine dehydrogenase and another molybdenum-containing protein in wheat, barley, and pea seedlings, and nitrate reductase and xanthine dehydrogenase in bacteroides from lupine nodules. Nitrogenase could not be detected by the method. 16 refs., 5 figs

  7. High-sensitive portable ASE-2 X-ray analyzer of sulfur in mineral oil

    International Nuclear Information System (INIS)

    Anchugov, I.S.; Goganov, A.D.; Plotnikov, R.I.

    2007-01-01

    The high-sensitivity ASE-2 analyzer of sulfur on the basis of existing ASE-I device is designed. ASE-2 analyzer realizes a standard method of energy dispersion X-ray fluorescent determinations of a sulfur mass fraction in mineral oil and allows to carry out the quantitative determination of sulfur in hydrocarbonic raw material and fuel in a 0.002-5 mass.% range [ru

  8. Measuring high-sensitivity cardiac troponin T blood concentration in population surveys.

    OpenAIRE

    Lazzarino, AI; Mindell, JS

    2017-01-01

    Introduction The blood test for high-sensitivity cardiac troponin T (HS-CTnT) has been proposed as a marker of cardiovascular risk in the general population, as it is associated with subsequent incidence of cardiovascular events and mortality. We aimed at evaluating the feasibility of HS-CTnT testing within large nationally-representative population surveys in which blood samples are collected during household visits, shipped using the standard civil postal service, and then frozen for subseq...

  9. Measuring high-sensitivity cardiac troponin T blood concentration in population surveys

    OpenAIRE

    Lazzarino, A. I.; Mindell, J. S.

    2017-01-01

    INTRODUCTION: The blood test for high-sensitivity cardiac troponin T (HS-CTnT) has been proposed as a marker of cardiovascular risk in the general population, as it is associated with subsequent incidence of cardiovascular events and mortality. We aimed at evaluating the feasibility of HS-CTnT testing within large nationally-representative population surveys in which blood samples are collected during household visits, shipped using the standard civil postal service, and then frozen for subse...

  10. High?Sensitivity Troponin: A Clinical Blood Biomarker for Staging Cardiomyopathy in Fabry Disease

    OpenAIRE

    2016-01-01

    Background High?sensitivity troponin (hs?TNT), a biomarker of myocardial damage, might be useful for assessing fibrosis in Fabry cardiomyopathy. We performed a prospective analysis of hs?TNT as a biomarker for myocardial changes in Fabry patients and a retrospective longitudinal follow?up study to assess longitudinal hs?TNT changes relative to fibrosis and cardiomyopathy progression. Methods and Results For the prospective analysis, hs?TNT from 75 consecutive patients with genetically confirm...

  11. Thomson scattering measuring device using high sensitivity photomultipliers: 16% up to 860nm

    International Nuclear Information System (INIS)

    Hesse, M.

    1976-03-01

    Photomultipliers with high quantum efficiency were used to observe the entire rubis laser light spectrum scattered by a plasma. The optical and electronic acquisition device used to study this spectrum is described. The spectra obtained revealed a dissymmetry larger than that expected from relativistic theory. These results could not be interpreted. The diagnostic sensitivity allows the measurement of low electron densities (2.10 12 ecm -3 ) [fr

  12. Study on fluorescence-sensitization of 3 variations of scintillators in high speed autoradiography

    International Nuclear Information System (INIS)

    Wang Zhenli; Liu Guimin

    1993-01-01

    The sensitizing effects of POPOP, PBD and PPO were compared in 3 H-TdR incorporation experiment, 3 H-TdR low and high concentration twice labelling experiment and a cell migration tracer experiment. The results indicate that 7.5% PPO in xylene with an exposure time of 48 h is most satisfactory. The efficiency was increased for 15-20 times

  13. A highly sensitive electrochemical glucose sensor structuring with nickel hydroxide and enzyme glucose oxidase

    International Nuclear Information System (INIS)

    Mathew, Manjusha; Sandhyarani, N.

    2013-01-01

    Graphical abstract: A combination of Ni 2+ /Ni 3+ redox couple and glucose oxidase has successfully been exploited for the realization of a highly sensitive glucose sensor for the first time. -- Highlights: • A multilayered glucose biosensor with enhanced sensitivity was fabricated. • Combination of Ni 2+ /Ni 3+ redox couple and glucose oxidase has been exploited for the first time. • Exhibits a lower detection limit of 100 nM with a high sensitivity of 16,840 μA mM −1 cm −2 . • The surface shows a low Michaelis–Menten constant value of 2.4 μM. • Detailed mechanism of sensing was proposed and justified. -- Abstract: A multilayered glucose biosensor with enhanced electron transport was fabricated via the sequential electrodeposition of chitosan gold nanocomposite (CGNC) and nickel hydroxide (Ni(OH) 2 ) on a bare gold electrode and subsequent immobilization of glucose oxidase. A thin film of Ni(OH) 2 deposited on CGNC modified gold electrode serves as an electrochemical redox probe as well as a matrix for the immobilization of glucose oxidase retaining its activity. Electron transport property of CGNC has been exploited to enhance the electron transport between the analyte and electrode. Electrochemical characteristics of the biosensor were studied by cyclic voltammetry and chronoamperometry. Under optimal conditions the biosensor exhibits a linear range from 1 μM to 100 μM with a limit of detection (lod) down to 100 nM. The sensor shows a low Michaelis-Menten constant value of 2.4 μM indicates the high affinity of enzyme to the analyte points to the retained activity of enzyme after immobilization. The present glucose sensor with the high selectivity, sensitivity and stability is promising for practical clinical applications

  14. Establishment of cell lines derived from ataxia telangiectasia and xeroderma pigmentosum patients with high radiation sensitivity

    International Nuclear Information System (INIS)

    Hashimoto, Tomoko; Furuyama, Jun-ichi; Nakano, Yoshiro; Owada, M. Koji; Kakunaga, Takeo

    1986-01-01

    Four human fibroblast cell lines, three of which were derived from a patient with ataxia telangiectasia and the other from a patient with xeroderma pigmentosum, were established after transfection with cloned SV40 DNA. These 4 cell lines showed some phenotypes characteristic of neoplastically transformed cells, and had a human karyotype with heteromorphisms identical to those of the parental fibroblasts. Their sensitivity to the cytotoxic effects of γ-rays or ultraviolet irradiation was as high as those of their parental fibroblasts. (Auth.)

  15. High-Sensitivity, Highly Transparent, Gel-Gated MoS2 Phototransistor on Biodegradable Nanopaper

    KAUST Repository

    Zhang, Qing

    2016-06-21

    Transition metal dichalcogenides hold great promise for a variety of novel electrical, optical and mechanical devices and applications. Among them, molybdenum disulphide (MoS2) is gaining increasing attention as the gate dielectric and semiconductive channel for high-perfomance field effect transistors. Here we report on the first MoS2 phototransistor built on flexible, transparent and biodegradable substrate with electrolyte gate dielectric. We have carried out systematic studies on its electrical and optoelectronic properties. The MoS2 phototransistor exhibited excellent photo responsivity of ~1.5 kA/W, about two times higher compared to typical back-gated devices reported in previous studies. The device is highly transparent at the same time with an average optical transmittance of 82%. Successful fabrication of phototransistors on flexible cellulose nanopaper with excellent performance and transparency suggests that it is feasible to achieve an ecofriendly, biodegradable phototransistor with great photoresponsivity, broad spectral range and durable flexibility.

  16. High-Sensitivity, Highly Transparent, Gel-Gated MoS2 Phototransistor on Biodegradable Nanopaper

    KAUST Repository

    Zhang, Qing; Bao, Wenzhong; Gong, Amy; Gong, Tao; Ma, Dakang; Wan, Jiayu; Dai, Jiaqi; Munday, J; He, Jr-Hau; Hu, Liangbing; Zhang, Daihua

    2016-01-01

    Transition metal dichalcogenides hold great promise for a variety of novel electrical, optical and mechanical devices and applications. Among them, molybdenum disulphide (MoS2) is gaining increasing attention as the gate dielectric and semiconductive channel for high-perfomance field effect transistors. Here we report on the first MoS2 phototransistor built on flexible, transparent and biodegradable substrate with electrolyte gate dielectric. We have carried out systematic studies on its electrical and optoelectronic properties. The MoS2 phototransistor exhibited excellent photo responsivity of ~1.5 kA/W, about two times higher compared to typical back-gated devices reported in previous studies. The device is highly transparent at the same time with an average optical transmittance of 82%. Successful fabrication of phototransistors on flexible cellulose nanopaper with excellent performance and transparency suggests that it is feasible to achieve an ecofriendly, biodegradable phototransistor with great photoresponsivity, broad spectral range and durable flexibility.

  17. Hybridization chain reaction amplification for highly sensitive fluorescence detection of DNA with dextran coated microarrays.

    Science.gov (United States)

    Chao, Jie; Li, Zhenhua; Li, Jing; Peng, Hongzhen; Su, Shao; Li, Qian; Zhu, Changfeng; Zuo, Xiaolei; Song, Shiping; Wang, Lianhui; Wang, Lihua

    2016-07-15

    Microarrays of biomolecules hold great promise in the fields of genomics, proteomics, and clinical assays on account of their remarkably parallel and high-throughput assay capability. However, the fluorescence detection used in most conventional DNA microarrays is still limited by sensitivity. In this study, we have demonstrated a novel universal and highly sensitive platform for fluorescent detection of sequence specific DNA at the femtomolar level by combining dextran-coated microarrays with hybridization chain reaction (HCR) signal amplification. Three-dimensional dextran matrix was covalently coated on glass surface as the scaffold to immobilize DNA recognition probes to increase the surface binding capacity and accessibility. DNA nanowire tentacles were formed on the matrix surface for efficient signal amplification by capturing multiple fluorescent molecules in a highly ordered way. By quantifying microscopic fluorescent signals, the synergetic effects of dextran and HCR greatly improved sensitivity of DNA microarrays, with a detection limit of 10fM (1×10(5) molecules). This detection assay could recognize one-base mismatch with fluorescence signals dropped down to ~20%. This cost-effective microarray platform also worked well with samples in serum and thus shows great potential for clinical diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Physical nature of strain rate sensitivity of metals and alloys at high strain rates

    Science.gov (United States)

    Borodin, E. N.; Gruzdkov, A. A.; Mayer, A. E.; Selyutina, N. S.

    2018-04-01

    The role of instabilities of plastic flow at plastic deformation of various materials is one of the important cross-disciplinary problems which is equally important in physics, mechanics and material science. The strain rate sensitivities under slow and high strain rate conditions of loading have different physical nature. In the case of low strain rate, the sensitivity arising from the inertness of the defect structures evolution can be expressed by a single parameter characterizing the plasticity mechanism. In our approach, this is the value of the characteristic relaxation time. In the dynamic case, there are additional effects of “high-speed sensitivity” associated with the micro-localization of the plastic flow near the stress concentrators. In the frames of mechanical description, this requires to introduce additional strain rate sensitivity parameters, which is realized in numerous modifications of Johnson–Cook and Zerilli–Armstrong models. The consideration of both these factors is fundamental for an adequate description of the problems of dynamic deformation of highly inhomogeneous metallic materials such as steels and alloys. The measurement of the dispersion of particle velocities on the free surface of a shock-loaded material can be regarded as an experimental expression of the effect of micro-localization. This is also confirmed by our results of numerical simulation of the propagation of shock waves in a two-dimensional formulation and analytical estimations.

  19. Current status on the evaluation and management of the highly sensitized kidney transplant recipient.

    Science.gov (United States)

    Kumar, Vineeta

    2015-11-01

    In light of the recent changes to the kidney allocation system (KAS) and the observed increase in the rate of transplantation of the highly sensitized kidney transplant candidate, the evaluation and care of this population is a timely topic. In its first year, the new KAS has already realized one goal of improving the chances of transplanting the most highly sensitized patients in the waiting list. This has brought to the forefront the need for recipient readiness in this special population, as well as the need for histocompatibility labs and kidney transplant programs to align themselves with each other, and also with the requirements of the United Network for Organ Sharing, and increase proficiency in testing and data interpretation. This manuscript is a review of the literature as well as practice patterns as they relate to the changes in KAS and the observed outcome since the activation of the new KAS, with the ultimate goal of aiding in the development of a more unified approach in the care of this specialized population which will allow for interdisciplinary and cross centre dialogue to optimize long term care and outcomes. Here we will review the changes to the KAS as they affect the highly sensitized kidney transplant recipient, and additional considerations in the evaluation and management of these patients.

  20. Quantum Dot-Fullerene Based Molecular Beacon Nanosensors for Rapid, Highly Sensitive Nucleic Acid Detection.

    Science.gov (United States)

    Liu, Ye; Kannegulla, Akash; Wu, Bo; Cheng, Li-Jing

    2018-05-15

    Spherical fullerene (C 60 ) can quench the fluorescence of a quantum dot (QD) through energy transfer and charge transfer processes, with the quenching efficiency regulated by the number of proximate C 60 on each QD. With the quenching property and its small size compared with other nanoparticle-based quenchers, it is advantageous to group a QD reporter and multiple C 60 -labeled oligonucleotide probes to construct a molecular beacon (MB) probe for sensitive, robust nucleic acid detection. We demonstrated a rapid, high-sensitivity DNA detection method using the nanosensors composed of QD-C 60 based MBs carried by magnetic nanoparticles (MNPs). The assay was accelerated by first dispersing the nanosensors in analytes for highly efficient DNA capture resulting from short-distance 3-dimensional diffusion of targets to the sensor surface and then concentrating the nanosensors to a substrate by magnetic force to amplify the fluorescence signal for target quantification. The enhanced mass transport enabled a rapid detection (< 10 min) with a small sample volume (1-10 µl). The high signal-to-noise ratio produced by the QD-C 60 pairs and magnetic concentration yielded a detection limit of 100 fM (~106 target DNA copies for a 10 µl analyte). The rapid, sensitive, label-free detection method will benefit the applications in point-of-care molecular diagnostic technologies.

  1. Highly sensitive ratiometric detection of heparin and its oversulfated chondroitin sulfate contaminant by fluorescent peptidyl probe.

    Science.gov (United States)

    Mehta, Pramod Kumar; Lee, Hyeri; Lee, Keun-Hyeung

    2017-05-15

    The selective and sensitive detection of heparin, an anticoagulant in clinics as well as its contaminant oversulfated chondroitin sulfate (OSCS) is of great importance. We first reported a ratiometric sensing method for heparin as well as OSCS contaminants in heparin using a fluorescent peptidyl probe (Pep1, pyrene-GSRKR) and heparin-digestive enzyme. Pep1 exhibited a highly sensitive ratiometric response to nanomolar concentration of heparin in aqueous solution over a wide pH range (2~11) and showed highly selective ratiometric response to heparin among biological competitors such as hyaluronic acid and chondroitin sulfate. Pep1 showed a linear ratiometric response to nanomolar concentrations of heparin in aqueous solutions and in human serum samples. The detection limit for heparin was calculated to be 2.46nM (R 2 =0.99) in aqueous solutions, 2.98nM (R 2 =0.98) in 1% serum samples, and 3.43nM (R 2 =0.99) in 5% serum samples. Pep1 was applied to detect the contaminated OSCS in heparin with heparinase I, II, and III, respectively. The ratiometric sensing method using Pep1 and heparinase II was highly sensitive, fast, and efficient for the detection of OSCS contaminant in heparin. Pep1 with heparinase II could detect as low as 0.0001% (w/w) of OSCS in heparin by a ratiometric response. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. The probability distribution of intergranular stress corrosion cracking life for sensitized 304 stainless steels in high temperature, high purity water

    International Nuclear Information System (INIS)

    Akashi, Masatsune; Kenjyo, Takao; Matsukura, Shinji; Kawamoto, Teruaki

    1984-01-01

    In order to discuss the probability distribution of intergranular stress corrsion carcking life for sensitized 304 stainless steels, a series of the creviced bent beem (CBB) and the uni-axial constant load tests were carried out in oxygenated high temperature, high purity water. The following concludions were resulted; (1) The initiation process of intergranular stress corrosion cracking has been assumed to be approximated by the Poisson stochastic process, based on the CBB test results. (2) The probability distribution of intergranular stress corrosion cracking life may consequently be approximated by the exponential probability distribution. (3) The experimental data could be fitted to the exponential probability distribution. (author)

  3. The functional highly sensitive brain: a review of the brain circuits underlying sensory processing sensitivity and seemingly related disorders.

    Science.gov (United States)

    Acevedo, Bianca; Aron, Elaine; Pospos, Sarah; Jessen, Dana

    2018-04-19

    During the past decade, research on the biological basis of sensory processing sensitivity (SPS)-a genetically based trait associated with greater sensitivity and responsivity to environmental and social stimuli-has burgeoned. As researchers try to characterize this trait, it is still unclear how SPS is distinct from seemingly related clinical disorders that have overlapping symptoms, such as sensitivity to the environment and hyper-responsiveness to incoming stimuli. Thus, in this review, we compare the neural regions implicated in SPS with those found in fMRI studies of-Autism Spectrum Disorder (ASD), Schizophrenia (SZ) and Post-Traumatic Stress Disorder (PTSD) to elucidate the neural markers and cardinal features of SPS versus these seemingly related clinical disorders. We propose that SPS is a stable trait that is characterized by greater empathy, awareness, responsivity and depth of processing to salient stimuli. We conclude that SPS is distinct from ASD, SZ and PTSD in that in response to social and emotional stimuli, SPS differentially engages brain regions involved in reward processing, memory, physiological homeostasis, self-other processing, empathy and awareness. We suggest that this serves species survival via deep integration and memory for environmental and social information that may subserve well-being and cooperation.This article is part of the theme issue 'Diverse perspectives on diversity: multi-disciplinary approaches to taxonomies of individual differences'. © 2018 The Authors.

  4. Sensitivity analysis of recovery efficiency in high-temperature aquifer thermal energy storage with single well

    International Nuclear Information System (INIS)

    Jeon, Jun-Seo; Lee, Seung-Rae; Pasquinelli, Lisa; Fabricius, Ida Lykke

    2015-01-01

    High-temperature aquifer thermal energy storage system usually shows higher performance than other borehole thermal energy storage systems. Although there is a limitation in the widespread use of the HT-ATES system because of several technical problems such as clogging, corrosion, etc., it is getting more attention as these issues are gradually alleviated. In this study, a sensitivity analysis of recovery efficiency in two cases of HT-ATES system with a single well is conducted to select key parameters. For a fractional factorial design used to choose input parameters with uniformity, the optimal Latin hypercube sampling with an enhanced stochastic evolutionary algorithm is considered. Then, the recovery efficiency is obtained using a computer model developed by COMSOL Multiphysics. With input and output variables, the surrogate modeling technique, namely the Gaussian-Kriging method with Smoothly Clopped Absolute Deviation Penalty, is utilized. Finally, the sensitivity analysis is performed based on the variation decomposition. According to the result of sensitivity analysis, the most important input variables are selected and confirmed to consider the interaction effects for each case and it is confirmed that key parameters vary with the experiment domain of hydraulic and thermal properties as well as the number of input variables. - Highlights: • Main and interaction effects on recovery efficiency in HT-ATES was investigated. • Reliability depended on fractional factorial design and interaction effects. • Hydraulic permeability of aquifer had an important impact on recovery efficiency. • Site-specific sensitivity analysis of HT-ATES was recommended.

  5. High intensity interval training improves liver and adipose tissue insulin sensitivity

    Science.gov (United States)

    Marcinko, Katarina; Sikkema, Sarah R.; Samaan, M. Constantine; Kemp, Bruce E.; Fullerton, Morgan D.; Steinberg, Gregory R.

    2015-01-01

    Objective Endurance exercise training reduces insulin resistance, adipose tissue inflammation and non-alcoholic fatty liver disease (NAFLD), an effect often associated with modest weight loss. Recent studies have indicated that high-intensity interval training (HIIT) lowers blood glucose in individuals with type 2 diabetes independently of weight loss; however, the organs affected and mechanisms mediating the glucose lowering effects are not known. Intense exercise increases phosphorylation and inhibition of acetyl-CoA carboxylase (ACC) by AMP-activated protein kinase (AMPK) in muscle, adipose tissue and liver. AMPK and ACC are key enzymes regulating fatty acid metabolism, liver fat content, adipose tissue inflammation and insulin sensitivity but the importance of this pathway in regulating insulin sensitivity with HIIT is unknown. Methods In the current study, the effects of 6 weeks of HIIT were examined using obese mice with serine–alanine knock-in mutations on the AMPK phosphorylation sites of ACC1 and ACC2 (AccDKI) or wild-type (WT) controls. Results HIIT lowered blood glucose and increased exercise capacity, food intake, basal activity levels, carbohydrate oxidation and liver and adipose tissue insulin sensitivity in HFD-fed WT and AccDKI mice. These changes occurred independently of weight loss or reductions in adiposity, inflammation and liver lipid content. Conclusions These data indicate that HIIT lowers blood glucose levels by improving adipose and liver insulin sensitivity independently of changes in adiposity, adipose tissue inflammation, liver lipid content or AMPK phosphorylation of ACC. PMID:26909307

  6. Highly Sensitive Liquid Core Temperature Sensor Based on Multimode Interference Effects

    Directory of Open Access Journals (Sweden)

    Miguel A. Fuentes-Fuentes

    2015-10-01

    Full Text Available A novel fiber optic temperature sensor based on a liquid-core multimode interference device is demonstrated. The advantage of such structure is that the thermo-optic coefficient (TOC of the liquid is at least one order of magnitude larger than that of silica and this, combined with the fact that the TOC of silica and the liquid have opposite signs, provides a liquid-core multimode fiber (MMF highly sensitive to temperature. Since the refractive index of the liquid can be easily modified, this allows us to control the modal properties of the liquid-core MMF at will and the sensor sensitivity can be easily tuned by selecting the refractive index of the liquid in the core of the device. The maximum sensitivity measured in our experiments is 20 nm/°C in the low-temperature regime up to 60 °C. To the best of our knowledge, to date, this is the largest sensitivity reported for fiber-based MMI temperature sensors.

  7. A flexible, highly sensitive catheter for high resolution manometry based on in-fibre Bragg gratings

    International Nuclear Information System (INIS)

    Bueley, Christopher; Wild, Peter M

    2013-01-01

    This work presents a fibre optic-based flexible catheter for high resolution manometry (HRM), with sensing pods located at a pitch of 10 mm and an overall diameter of 2.8 mm. In-fibre Bragg gratings act as the sensing elements within these sensing pods. Hydrodynamic pressure resolution of 0.2 mmHg is demonstrated in conjunction with insensitivity to occlusion pressure. This result is significant in the context of HRM where independent measurement of hydrodynamic pressure is clinically relevant. The sensing system is compact, robust and flexible. Crosstalk between individual sensors is characterized and a compensation scheme is developed and validated. (paper)

  8. An automated quantitative DNA image cytometry system detects abnormal cells in cervical cytology with high sensitivity.

    Science.gov (United States)

    Wong, O G; Ho, M W; Tsun, O K; Ng, A K; Tsui, E Y; Chow, J N; Ip, P P; Cheung, A N

    2018-03-26

    To evaluate the performance of an automated DNA-image-cytometry system as a tool to detect cervical carcinoma. Of 384 liquid-based cervical cytology samples with available biopsy follow-up were analyzed by both the Imager System and a high-risk HPV test (Cobas). The sensitivity and specificity of Imager System for detecting biopsy proven high-grade squamous intraepithelial lesion (HSIL, cervical intraepithelial neoplasia [CIN]2-3) and carcinoma were 89.58% and 56.25%, respectively, compared to 97.22% and 23.33% of HPV test but additional HPV 16/18 genotyping increased the specificity to 69.58%. The sensitivity and specificity of the Imager System for predicting HSIL+ (CIN2-3+) lesions among atypical squamous cells of undetermined significance samples were 80.00% and 70.53%, respectively, compared to 100% and 11.58% of HPV test whilst the HPV 16/18 genotyping increased the specificity to 77.89%. Among atypical squamous cells-cannot exclude HSIL, the sensitivity and specificity of Imager System for predicting HSIL+ (CIN2-3+) lesions upon follow up were 82.86% and 33.33%%, respectively, compared to 97.14% and 4.76% of HPV test and the HPV 16/18 genotyping increased the specificity to 19.05%. Among low-grade squamous intraepithelial lesion cases, the sensitivity and specificity of the Imager System for predicting HSIL+ (CIN2-3+) lesions were 66.67% and 35.71%%, respectively, compared to 66.67% and 29.76% of HPV test while HPV 16/18 genotyping increased the specificity to 79.76%. The overall results of imager and high-risk HPV test agreed in 69.43% (268) of all samples. The automated imager system and HPV 16/18 genotyping can enhance the specificity of detecting HSIL+ (CIN2-3+) lesions. © 2018 John Wiley & Sons Ltd.

  9. Controlled assembly of organic whispering-gallery-mode microlasers as highly sensitive chemical vapor sensors.

    Science.gov (United States)

    Gao, Miaomiao; Wei, Cong; Lin, Xianqing; Liu, Yuan; Hu, Fengqin; Zhao, Yong Sheng

    2017-03-09

    We demonstrate the fabrication of organic high Q active whispering-gallery-mode (WGM) resonators from π-conjugated polymer by a controlled emulsion-solvent-evaporation method, which can simultaneously provide optical gain and act as an effective resonant cavity. By measuring the shift of their lasing modes on exposure to organic vapor, we successfully monitored the slight concentration variation in the chemical gas. These microlaser sensors demonstrated high detection sensitivity and good signal repeatability under continuous chemical gas treatments. The results offer an effective strategy to design miniaturized optical sensors.

  10. Towards sensitive, high-throughput, biomolecular assays based on fluorescence lifetime

    Science.gov (United States)

    Ioanna Skilitsi, Anastasia; Turko, Timothé; Cianfarani, Damien; Barre, Sophie; Uhring, Wilfried; Hassiepen, Ulrich; Léonard, Jérémie

    2017-09-01

    Time-resolved fluorescence detection for robust sensing of biomolecular interactions is developed by implementing time-correlated single photon counting in high-throughput conditions. Droplet microfluidics is used as a promising platform for the very fast handling of low-volume samples. We illustrate the potential of this very sensitive and cost-effective technology in the context of an enzymatic activity assay based on fluorescently-labeled biomolecules. Fluorescence lifetime detection by time-correlated single photon counting is shown to enable reliable discrimination between positive and negative control samples at a throughput as high as several hundred samples per second.

  11. Improving sensitivity of residual current transformers to high frequency earth fault currents

    Directory of Open Access Journals (Sweden)

    Czapp Stanislaw

    2017-09-01

    Full Text Available For protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed the modification in the structure of residual current devices. This modification improves sensitivity of residual current devices when high frequency earth fault current occurs. The test of the modified residual current device proved that the authors’ proposition is appropriate.

  12. Creating geometrically robust designs for highly sensitive problems using topology optimization: Acoustic cavity design

    DEFF Research Database (Denmark)

    Christiansen, Rasmus E.; Lazarov, Boyan S.; Jensen, Jakob S.

    2015-01-01

    Resonance and wave-propagation problems are known to be highly sensitive towards parameter variations. This paper discusses topology optimization formulations for creating designs that perform robustly under spatial variations for acoustic cavity problems. For several structural problems, robust...... and limitations are discussed. In addition, a known explicit penalization approach is considered for comparison. For near-uniform spatial variations it is shown that highly robust designs can be obtained using the double filter approach. It is finally demonstrated that taking non-uniform variations into account...... further improves the robustness of the designs....

  13. High speed USB data logger for position sensitive detector data acquisition

    International Nuclear Information System (INIS)

    Poudel, S.K.; Kulkarni, V.B.; Kumar, Santosh; Chandak, R.M.; Krishna, P.S.R.; Mukhopadhyay, R.

    2010-01-01

    Ratio ADC (RDC) module used in neutron Position Sensitive Detector (PSD) data acquisition, gives digital code signifying the position of neutron event. A High Speed USB based RDC Data Logger card has been made for logging data from multiple RDCs to PC. A CPLD on the card continuously polls the RDCs for data, and fills it in the FIFO memory of a high speed USB microcontroller. A VC++ program for neutron scattering experiments reads event codes from FIFO of microcontroller and builds spectrum on PC. This program sweeps physical parameters of sample and collects PSD data for pre-determined monitor counts. (author)

  14. Anxious and angry rejection sensitivity, social withdrawal, and retribution in high and low ambiguous situations.

    Science.gov (United States)

    Zimmer-Gembeck, Melanie J; Nesdale, Drew

    2013-02-01

    Rejection sensitivity (RS) is a tendency to expect, perceive, and overreact to rejection. Our objective was to examine whether anxious and angry RS have specific associations with negative social reactions, and whether responses are intensified in situations of high rejection ambiguity. In two studies, youth (N = 464 and N = 371) reported their RS and anticipated responses to social scenarios. In Study 1, all scenarios portrayed overt rejection events. In Study 2, participants were randomly assigned to conditions portraying overt or ambiguous rejection. Greater rejection expectation was associated with more negative reactions to rejection. Moreover, as expected, anxiety about rejection was uniquely associated with withdrawal, and anger about rejection was uniquely associated with retribution (i.e., reactive aggression). In the second study, RS persons responded more negatively than others to both overt and high ambiguous rejections, but retribution was intensified among participants high in rejection expectation when rejection was ambiguous, and withdrawal was intensified among participants high in anxious RS in overt rejection situations. Consistent with the revised RS model, there are different patterns of emotions, cognitions, and behaviors in response to high and low ambiguous rejection events, which are heightened in youth sensitive to rejection. © 2012, Wiley Periodicals, Inc.

  15. Highly Sensitive and Very Stretchable Strain Sensor Based on a Rubbery Semiconductor.

    Science.gov (United States)

    Kim, Hae-Jin; Thukral, Anish; Yu, Cunjiang

    2018-02-07

    There is a growing interest in developing stretchable strain sensors to quantify the large mechanical deformation and strain associated with the activities for a wide range of species, such as humans, machines, and robots. Here, we report a novel stretchable strain sensor entirely in a rubber format by using a solution-processed rubbery semiconductor as the sensing material to achieve high sensitivity, large mechanical strain tolerance, and hysteresis-less and highly linear responses. Specifically, the rubbery semiconductor exploits π-π stacked poly(3-hexylthiophene-2,5-diyl) nanofibrils (P3HT-NFs) percolated in silicone elastomer of poly(dimethylsiloxane) to yield semiconducting nanocomposite with a large mechanical stretchability, although P3HT is a well-known nonstretchable semiconductor. The fabricated strain sensors exhibit reliable and reversible sensing capability, high gauge factor (gauge factor = 32), high linearity (R 2 > 0.996), and low hysteresis (degree of hysteresis wearable smart gloves. Systematic investigations in the materials design and synthesis, sensor fabrication and characterization, and mechanical analysis reveal the key fundamental and application aspects of the highly sensitive and very stretchable strain sensors entirely from rubbers.

  16. Fabrication of highly catalytic silver nanoclusters/graphene oxide nanocomposite as nanotag for sensitive electrochemical immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jiamian; Wang, Xiuyun; Wu, Shuo, E-mail: wushuo@dlut.edu.cn; Song, Jie; Zhao, Yanqiu; Ge, Yanqiu; Meng, Changgong

    2016-02-04

    Silver nanoclusters and graphene oxide nanocomposite (AgNCs/GRO) is synthesized and functionalized with detection antibody for highly sensitive electrochemical sensing of carcinoembryonic antigen (CEA), a model tumor marker involved in many cancers. AgNCs with large surface area and abundant amount of low-coordinated sites are synthesized with DNA as template and exhibit high catalytic activity towards the electrochemical reduction of H{sub 2}O{sub 2}. GRO is employed to assemble with AgNCs because it has large specific surface area, super electronic conductivity and strong π-π stacking interaction with the hydrophobic bases of DNA, which can further improve the catalytic ability of the AgNCs. Using AgNCs/GRO as signal amplification tag, an enzyme-free electrochemical immunosensing protocol is designed for the highly sensitive detection of CEA on the capture antibody functionalized immunosensing interface. Under optimal conditions, the designed immunosensor exhibits a wide linear range from 0.1 pg mL{sup −1} to 100 ng mL{sup −1} and a low limit of detection of 0.037 pg mL{sup −1}. Practical sample analysis reveals the sensor has good accuracy and reproducibility, indicating the great application prospective of the AgNCs/GRO in fabricating highly sensitive immunosensors, which can be extended to the detection of various kinds of low abundance disease related proteins. - Highlights: • An enzyme-free electrochemical immunosensor is reported for detecting proteins. • A silver nanocluster/graphene oxide composite is synthesized as nanotag. • The nanotags exhibit highly catalytic activity to the electro-reduction of H{sub 2}O{sub 2}. • The as-fabricated immunosensor could detect protein in serum samples.

  17. Finger tapping impairments are highly sensitive for evaluating upper motor neuron lesions.

    Science.gov (United States)

    Shirani, Afsaneh; Newton, Braeden D; Okuda, Darin T

    2017-03-21

    Identifying highly sensitive and reliable neurological exam components are crucial in recognizing clinical deficiencies. This study aimed to investigate finger tapping performance differences between patients with CNS demyelinating lesions and healthy control subjects. Twenty-three patients with multiple sclerosis or clinically isolated syndrome with infratentorial and/or cervical cord lesions on MRI, and 12 healthy controls were videotaped while tapping the tip of the index finger against the tip and distal crease of the thumb using both the dominant and non-dominant hand. Videos were assessed independently by 10 evaluators (three MS neurologists, four neurology residents, three advanced practice providers). Sensitivity and inter-evaluator reliability of finger tapping interpretations were calculated. A total of 1400 evaluations (four videos per each of the 35 subjects evaluated by 10 independent providers) were obtained. Impairments in finger tapping against the distal thumb crease of the non-dominant hand, identified by neurologists, had the greatest sensitivity (84%, p tapping against the thumb crease was more sensitive than the thumb tip across all categories of providers. The best inter-evaluator reliability was associated with neurologists' evaluations for the thumb crease of the non-dominant hand (kappa = 0.83, p tapping against the distal thumb crease of the non-dominant hand was a more sensitive technique for detecting impairments related to CNS demyelinating lesions. Our findings highlight the importance of precise examinations of the non-dominant side where impaired fine motor control secondary to an upper motor injury might be detectable earlier than the dominant side.

  18. Moderate sensitivity and high specificity of emergency department administrative data for transient ischemic attacks.

    Science.gov (United States)

    Yu, Amy Y X; Quan, Hude; McRae, Andrew; Wagner, Gabrielle O; Hill, Michael D; Coutts, Shelagh B

    2017-09-18

    Validation of administrative data case definitions is key for accurate passive surveillance of disease. Transient ischemic attack (TIA) is a condition primarily managed in the emergency department. However, prior validation studies have focused on data after inpatient hospitalization. We aimed to determine the validity of the Canadian 10th International Classification of Diseases (ICD-10-CA) codes for TIA in the national ambulatory administrative database. We performed a diagnostic accuracy study of four ICD-10-CA case definition algorithms for TIA in the emergency department setting. The study population was obtained from two ongoing studies on the diagnosis of TIA and minor stroke versus stroke mimic using serum biomarkers and neuroimaging. Two reference standards were used 1) the emergency department clinical diagnosis determined by chart abstractors and 2) the 90-day final diagnosis, both obtained by stroke neurologists, to calculate the sensitivity, specificity, positive and negative predictive values (PPV and NPV) of the ICD-10-CA algorithms for TIA. Among 417 patients, emergency department adjudication showed 163 (39.1%) TIA, 155 (37.2%) ischemic strokes, and 99 (23.7%) stroke mimics. The most restrictive algorithm, defined as a TIA code in the main position had the lowest sensitivity (36.8%), but highest specificity (92.5%) and PPV (76.0%). The most inclusive algorithm, defined as a TIA code in any position with and without query prefix had the highest sensitivity (63.8%), but lowest specificity (81.5%) and PPV (68.9%). Sensitivity, specificity, PPV, and NPV were overall lower when using the 90-day diagnosis as reference standard. Emergency department administrative data reflect diagnosis of suspected TIA with high specificity, but underestimate the burden of disease. Future studies are necessary to understand the reasons for the low to moderate sensitivity.

  19. Determination of Chlorinated Hydrocarbons in Water Using Highly Sensitive Mid-Infrared Sensor Technology

    Science.gov (United States)

    Lu, Rui; Mizaikoff, Boris; Li, Wen-Wei; Qian, Chen; Katzir, Abraham; Raichlin, Yosef; Sheng, Guo-Ping; Yu, Han-Qing

    2013-08-01

    Chlorinated aliphatic hydrocarbons and chlorinated aromatic hydrocarbons (CHCs) are toxic and carcinogenic contaminants commonly found in environmental samples, and efficient online detection of these contaminants is still challenging at the present stage. Here, we report an advanced Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) sensor for in-situ and simultaneous detection of multiple CHCs, including monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, trichloroethylene, perchloroethylene, and chloroform. The polycrystalline silver halide sensor fiber had a unique integrated planar-cylindric geometry, and was coated with an ethylene/propylene copolymer membrane to act as a solid phase extractor, which greatly amplified the analytical signal and contributed to a higher detection sensitivity compared to the previously reported sensors. This system exhibited a high detection sensitivity towards the CHCs mixture at a wide concentration range of 5~700 ppb. The FTIR-ATR sensor described in this study has a high potential to be utilized as a trace-sensitive on-line device for water contamination monitoring.

  20. Highly Selective and Sensitive Self-Powered Glucose Sensor Based on Capacitor Circuit.

    Science.gov (United States)

    Slaughter, Gymama; Kulkarni, Tanmay

    2017-05-03

    Enzymatic glucose biosensors are being developed to incorporate nanoscale materials with the biological recognition elements to assist in the rapid and sensitive detection of glucose. Here we present a highly sensitive and selective glucose sensor based on capacitor circuit that is capable of selectively sensing glucose while simultaneously powering a small microelectronic device. Multi-walled carbon nanotubes (MWCNTs) is chemically modified with pyrroloquinoline quinone glucose dehydrogenase (PQQ-GDH) and bilirubin oxidase (BOD) at anode and cathode, respectively, in the biofuel cell arrangement. The input voltage (as low as 0.25 V) from the biofuel cell is converted to a stepped-up power and charged to the capacitor to the voltage of 1.8 V. The frequency of the charge/discharge cycle of the capacitor corresponded to the oxidation of glucose. The biofuel cell structure-based glucose sensor synergizes the advantages of both the glucose biosensor and biofuel cell. In addition, this glucose sensor favored a very high selectivity towards glucose in the presence of competing and non-competing analytes. It exhibited unprecedented sensitivity of 37.66 Hz/mM.cm 2 and a linear range of 1 to 20 mM. This innovative self-powered glucose sensor opens new doors for implementation of biofuel cells and capacitor circuits for medical diagnosis and powering therapeutic devices.

  1. Highly sensitive nano-porous lattice biosensor based on localized surface plasmon resonance and interference.

    Science.gov (United States)

    Yeom, Se-Hyuk; Kim, Ok-Geun; Kang, Byoung-Ho; Kim, Kyu-Jin; Yuan, Heng; Kwon, Dae-Hyuk; Kim, Hak-Rin; Kang, Shin-Won

    2011-11-07

    We propose a design for a highly sensitive biosensor based on nanostructured anodized aluminum oxide (AAO) substrates. A gold-deposited AAO substrate exhibits both optical interference and localized surface plasmon resonance (LSPR). In our sensor, application of these disparate optical properties overcomes problems of limited sensitivity, selectivity, and dynamic range seen in similar biosensors. We fabricated uniform periodic nanopore lattice AAO templates by two-step anodizing and assessed their suitability for application in biosensors by characterizing the change in optical response on addition of biomolecules to the AAO template. To determine the suitability of such structures for biosensing applications, we immobilized a layer of C-reactive protein (CRP) antibody on a gold coating atop an AAO template. We then applied a CRP antigen (Ag) atop the immobilized antibody (Ab) layer. The shift in reflectance is interpreted as being caused by the change in refractive index with membrane thickness. Our results confirm that our proposed AAO-based biosensor is highly selective toward detection of CRP antigen, and can measure a change in CRP antigen concentration of 1 fg/ml. This method can provide a simple, fast, and sensitive analysis for protein detection in real-time.

  2. Mesoporous structured MIPs@CDs fluorescence sensor for highly sensitive detection of TNT.

    Science.gov (United States)

    Xu, Shoufang; Lu, Hongzhi

    2016-11-15

    A facile strategy was developed to prepare mesoporous structured molecularly imprinted polymers capped carbon dots (M-MIPs@CDs) fluorescence sensor for highly sensitive and selective determination of TNT. The strategy using amino-CDs directly as "functional monomer" for imprinting simplify the imprinting process and provide well recognition sites accessibility. The as-prepared M-MIPs@CDs sensor, using periodic mesoporous silica as imprinting matrix, and amino-CDs directly as "functional monomer", exhibited excellent selectivity and sensitivity toward TNT with detection limit of 17nM. The recycling process was sustainable for 10 times without obvious efficiency decrease. The feasibility of the developed method in real samples was successfully evaluated through the analysis of TNT in soil and water samples with satisfactory recoveries of 88.6-95.7%. The method proposed in this work was proved to be a convenient and practical way to prepare high sensitive and selective fluorescence MIPs@CDs sensors. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Perovskite Nanoparticle-Sensitized Ga2O3 Nanorod Arrays for CO Detection at High Temperature.

    Science.gov (United States)

    Lin, Hui-Jan; Baltrus, John P; Gao, Haiyong; Ding, Yong; Nam, Chang-Yong; Ohodnicki, Paul; Gao, Pu-Xian

    2016-04-13

    Noble metal nanoparticles are extensively used for sensitizing metal oxide chemical sensors through the catalytic spillover mechanism. However, due to earth-scarcity and high cost of noble metals, finding replacements presents a great economic benefit. Besides, high temperature and harsh environment sensor applications demand material stability under conditions approaching thermal and chemical stability limits of noble metals. In this study, we employed thermally stable perovskite-type La(0.8)Sr(0.2)FeO3 (LSFO) nanoparticle surface decoration on Ga2O3 nanorod array gas sensors and discovered an order of magnitude enhanced sensitivity to carbon monoxide at 500 °C. The LSFO nanoparticle catalysts was of comparable performance to that achieved by Pt nanoparticles, with a much lower weight loading than Pt. Detailed electron microscopy and X-ray photoelectron spectroscopy studies suggested the LSFO nanoparticle sensitization effect is attributed to a spillover-like effect associated with the gas-LSFO-Ga2O3 triple-interfaces that spread the negatively charged surface oxygen ions from LSFO nanoparticles surfaces over to β-Ga2O3 nanorod surfaces with faster surface CO oxidation reactions.

  4. Influence of grain structure on quench sensitivity relative to localized corrosion of high strength aluminum alloy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, ShengDan, E-mail: csuliusd@163.com [School of Materials Science and Engineering, Central South University, Changsha 410083 (China); Key Laboratory of Nonferrous Metal Materials Science and Engineering, Ministry of Education, Changsha 410083 (China); Li, ChengBo [Light Alloy Research Institute, Central South University, Changsha 410083 (China); Deng, YunLai; Zhang, XinMing [School of Materials Science and Engineering, Central South University, Changsha 410083 (China); Key Laboratory of Nonferrous Metal Materials Science and Engineering, Ministry of Education, Changsha 410083 (China)

    2015-11-01

    The influence of grain structure on quench sensitivity relative to localized corrosion of high strength aluminum alloy 7055 was investigated by electrochemical test, accelerated exfoliation corrosion test, optical microscopy (OM), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM). The decrease of quench rate led to lower corrosion resistance of both the homogenized and solution heat treated (HS) alloy with equiaxed grains and the hot-rolled and solution heat treated (HRS) alloy with elongated grains, but there was a higher increment in corrosion depth and corrosion current density and a higher decrement in corrosion potential for the latter alloy, which therefore exhibited higher quench sensitivity. It is because in this alloy the larger amount of (sub) grain boundaries led to a higher increment in the amount of quench-induced η phase and precipitates free zone at (sub) grain boundaries with the decrease of quench rate, and there was a larger increment in the content of Zn, Mg and Cu in the η phase at grain boundaries due to slow quenching. The presence of subgrain boundaries in the HRS alloy tended to increase corrosion resistance at high quench rates higher than about 630 °C/min but decrease it at lower quench rates. - Highlights: • (Sub)Grain boundaries increase quench sensitivity relative to localized corrosion. • Subgrain boundaries decrease corrosion resistance below quench rate of 630 °C/min. • More (sub) grain boundaries leads to more GBPs and PFZ with decreasing quench rate.

  5. Highly sensitive three-dimensional interdigitated microelectrode for microparticle detection using electrical impedance spectroscopy

    International Nuclear Information System (INIS)

    Chang, Fu-Yu; Chen, Ming-Kun; Jang, Ling-Sheng; Wang, Min-Haw

    2016-01-01

    Cell impedance analysis is widely used for monitoring biological and medical reactions. In this study, a highly sensitive three-dimensional (3D) interdigitated microelectrode (IME) with a high aspect ratio on a polyimide (PI) flexible substrate was fabricated for microparticle detection (e.g. cell quantity detection) using electroforming and lithography technology. 3D finite element simulations were performed to compare the performance of the 3D IME (in terms of sensitivity and signal-to-noise ratio) to that of a planar IME for particles in the sensing area. Various quantities of particles were captured in Dulbecco’s modified Eagle medium and their impedances were measured. With the 3D IME, the particles were arranged in the gap, not on the electrode, avoiding the noise due to particle position. For the maximum particle quantities, the results show that the 3D IME has at least 5-fold higher sensitivity than that of the planar IME. The trends of impedance magnitude and phase due to particle quantity were verified using the equivalent circuit model. The impedance (1269 Ω) of 69 particles was used to estimate the particle quantity (68 particles) with 98.6% accuracy using a parabolic regression curve at 500 kHz. (paper)

  6. High sensitivity and high resolution element 3D analysis by a combined SIMS–SPM instrument

    Directory of Open Access Journals (Sweden)

    Yves Fleming

    2015-04-01

    Full Text Available Using the recently developed SIMS–SPM prototype, secondary ion mass spectrometry (SIMS data was combined with topographical data from the scanning probe microscopy (SPM module for five test structures in order to obtain accurate chemical 3D maps: a polystyrene/polyvinylpyrrolidone (PS/PVP polymer blend, a nickel-based super-alloy, a titanium carbonitride-based cermet, a reticle test structure and Mg(OH2 nanoclusters incorporated inside a polymer matrix. The examples illustrate the potential of this combined approach to track and eliminate artefacts related to inhomogeneities of the sputter rates (caused by samples containing various materials, different phases or having a non-flat surface and inhomogeneities of the secondary ion extraction efficiencies due to local field distortions (caused by topography with high aspect ratios. In this respect, this paper presents the measured relative sputter rates between PVP and PS as well as in between the different phases of the TiCN cermet.

  7. A high sensitivity, high throughput, automated single-cell gel electrophoresis ('Comet') DNA damage assay

    International Nuclear Information System (INIS)

    Vojnovic, B.; Barber, P.R.; Johnston, P.J.; Gregory, H.C.; Locke, R.J.

    2003-01-01

    A fully automated microscopy machine vision image capture and analysis system for the collection of data from slides of 'comets' has been developed. The novel image processing algorithms employed in delineating the 'comet head' from the 'comet tail' allow us to determine accurately very low levels of damage. In conjunction with calibrated and automated image capture methods, we are able to eliminate operator subjectivity and analyse large numbers of cells (>2500) in a short time (<1 hour). The image processing algorithm is designed to handle particularly difficult nuclei containing a high degree of structure, due to DNA clumping. We also present techniques used to extend the assay's dynamic range by removing interfering background fluorescence and to define a region of interest. If subtle biological variations are to be quantified (e.g. cell cycle dependant damage), then the use of large cell populations is dictated. Under those circumstances, the use of a fully automated system is particularly advantageous providing that the manner in which data is extracted does not introduce any inadvertent bias. In practice, it is essential that the image processing steps are geared towards the correct recognition of an acceptable cell nucleus, i.e. comet 'head'. We acknowledge the financial support of CRUK, Programme Grant C133/A1812 - SP 2195-01/02 and the US Department of Energy Low Dose Radiation Research Program grant DE-FG07-99ER62878

  8. Sensitivity to apomorphine-induced yawning and hypothermia in rats eating standard or high-fat chow.

    Science.gov (United States)

    Baladi, Michelle G; Thomas, Yvonne M; France, Charles P

    2012-07-01

    Feeding conditions modify sensitivity to indirect- and direct-acting dopamine receptor agonists as well as the development of sensitization to these drugs. This study examined whether feeding condition affects acute sensitivity to apomorphine-induced yawning or changes in sensitivity that occur over repeated drug administration. Quinpirole-induced yawning was also evaluated to see whether sensitization to apomorphine confers cross-sensitization to quinpirole. Drug-induced yawning was measured in different groups of male Sprague Dawley rats (n = 6/group) eating high (34.3%) fat or standard (5.7% fat) chow. Five weeks of eating high-fat chow rendered otherwise drug-naïve rats more sensitive to apomorphine- (0.01-1.0 mg/kg, i.p.) and quinpirole- (0.0032-0.32 mg/kg, i.p.) induced yawning, compared with rats eating standard chow. In other rats, tested weekly with apomorphine, sensitivity to apomorphine-induced yawning increased (sensitization) similarly in rats with free access to standard or high-fat chow; conditioning to the testing environment appeared to contribute to increased yawning in both groups of rats. Food restriction decreased sensitivity to apomorphine-induced yawning across five weekly tests. Rats with free access to standard or high-fat chow and sensitized to apomorphine were cross-sensitized to quinpirole-induced yawning. The hypothermic effects of apomorphine and quinpirole were not different regardless of drug history or feeding condition. Eating high-fat chow or restricting access to food alters sensitivity to direct-acting dopamine receptor agonists (apomorphine, quinpirole), although the relative contribution of drug history and dietary conditions to sensitivity changes appears to vary among agonists.

  9. Direct Printing of Stretchable Elastomers for Highly Sensitive Capillary Pressure Sensors.

    Science.gov (United States)

    Liu, Wenguang; Yan, Chaoyi

    2018-03-28

    We demonstrate the successful fabrication of highly sensitive capillary pressure sensors using an innovative 3D printing method. Unlike conventional capacitive pressure sensors where the capacitance changes were due to the pressure-induced interspace variations between the parallel plate electrodes, in our capillary sensors the capacitance was determined by the extrusion and extraction of liquid medium and consequent changes of dielectric constants. Significant pressure sensitivity advances up to 547.9 KPa -1 were achieved. Moreover, we suggest that our innovative capillary pressure sensors can adopt a wide range of liquid mediums, such as ethanol, deionized water, and their mixtures. The devices also showed stable performances upon repeated pressing cycles. The direct and versatile printing method combined with the significant performance advances are expected to find important applications in future stretchable and wearable electronics.

  10. A high-sensitive and quantitative in-line monitoring method for transplutonium elements separation processes

    International Nuclear Information System (INIS)

    Zhu Rongbao; Wang Shiju; Xu Yingpu; Zhang Zengrui

    1986-04-01

    A high-sensitive monitoring device and a quantitative analys technigue for transplutonium elements separation processes are described. X-ray and low energy γ-ray are measured by means of a scintillation monitor with two NaI(Tl) thin crystals. The α spectra of the fluents of ion-exchange column is measured by means of Si(Au) surface barrier in-line monitor. The construction of the monitors, auxiliary electronics, investigation result for the α spectra character of thick source and the calibration method were described. The determination results for extracting process of 243 Am and 244 Cm by ion-exchange chromatography were given. The sensitivity of total adding amount for 243 Am using the 4π scintillation monitor is better than 0.1 μCi. The precision of 243 Am and 244 Cm concentration determination using Si(Au) monitor is +- 5%. The precision of the two metals contents in containers is about +- 10%

  11. Design of a Piezoelectric Accelerometer with High Sensitivity and Low Transverse Effect

    Directory of Open Access Journals (Sweden)

    Bian Tian

    2016-09-01

    Full Text Available In order to meet the requirements of cable fault detection, a new structure of piezoelectric accelerometer was designed and analyzed in detail. The structure was composed of a seismic mass, two sensitive beams, and two added beams. Then, simulations including the maximum stress, natural frequency, and output voltage were carried out. Moreover, comparisons with traditional structures of piezoelectric accelerometer were made. To verify which vibration mode is the dominant one on the acceleration and the space between the mass and glass, mode analysis and deflection analysis were carried out. Fabricated on an n-type single crystal silicon wafer, the sensor chips were wire-bonged to printed circuit boards (PCBs and simply packaged for experiments. Finally, a vibration test was conducted. The results show that the proposed piezoelectric accelerometer has high sensitivity, low resonance frequency, and low transverse effect.

  12. The CAMEO project: high sensitivity quest for Majorana neutrino mass with the BOREXINO counting test facility

    International Nuclear Information System (INIS)

    Bellini, G.; Caccianiga, B.; Giammarchi, M.G.

    2001-01-01

    The unique features of the CTF and BOREXINO set-ups are used for a high sensitivity study of 100 Mo and 116 Cd neutrinoless 2β decay. Pilot measurements with 116 Cd and Monte Carlo simulation show that the sensitivity of the CAMEO experiment (in terms of the T 1/2 limit for 0ν2β decay) is (3-5) · 10 24 y with a 1 kg source of 100 Mo ( 116 Cd, 82 Se, 150 Nd) and ∼ 10 26 y with 65 kg of 116 CdWO 4 crystals placed in the CTF. The last value corresponds to a limit on the neutrino mass of m ν ≤ 0.06 eV. Moreover, with 1000 kg of 116 CdWO 4 crystals located in the BOREXINO apparatus, the neutrino mass limit can be pushed down to m ν ≤ 0.02 eV

  13. Cones fabricated by 3D nanoimprint lithography for highly sensitive surface enhanced Raman spectroscopy

    International Nuclear Information System (INIS)

    Wu Wei; Hu Min; Ou Fungsuong; Li Zhiyong; Williams, R Stanley

    2010-01-01

    We demonstrated a cost-effective and deterministic method of patterning 3D cone arrays over a large area by using nanoimprint lithography (NIL). Cones with tip radius of less than 10 nm were successfully duplicated onto the UV-curable imprint resist materials from the silicon cone templates. Such cone structures were shown to be a versatile platform for developing reliable, highly sensitive surface enhanced Raman spectroscopy (SERS) substrates. In contrast to the silicon nanocones, the SERS substrates based on the Au coated cones made by the NIL offered significant improvement of the SERS signal. A further improvement of the SERS signal was observed when the polymer cones were imprinted onto a reflective metallic mirror surface. A sub-zeptomole detection sensitivity for a model molecule, trans-1,2-bis(4-pyridyl)-ethylene (BPE), on the Au coated NIL cone surfaces was achieved.

  14. High spatial precision nano-imaging of polarization-sensitive plasmonic particles

    Science.gov (United States)

    Liu, Yunbo; Wang, Yipei; Lee, Somin Eunice

    2018-02-01

    Precise polarimetric imaging of polarization-sensitive nanoparticles is essential for resolving their accurate spatial positions beyond the diffraction limit. However, conventional technologies currently suffer from beam deviation errors which cannot be corrected beyond the diffraction limit. To overcome this issue, we experimentally demonstrate a spatially stable nano-imaging system for polarization-sensitive nanoparticles. In this study, we show that by integrating a voltage-tunable imaging variable polarizer with optical microscopy, we are able to suppress beam deviation errors. We expect that this nano-imaging system should allow for acquisition of accurate positional and polarization information from individual nanoparticles in applications where real-time, high precision spatial information is required.

  15. Quality and sensitivity of high-resolution numerical simulation of urban heat islands

    International Nuclear Information System (INIS)

    Li, Dan; Bou-Zeid, Elie

    2014-01-01

    High-resolution numerical simulations of the urban heat island (UHI) effect with the widely-used Weather Research and Forecasting (WRF) model are assessed. Both the sensitivity of the results to the simulation setup, and the quality of the simulated fields as representations of the real world, are investigated. Results indicate that the WRF-simulated surface temperatures are more sensitive to the planetary boundary layer (PBL) scheme choice during nighttime, and more sensitive to the surface thermal roughness length parameterization during daytime. The urban surface temperatures simulated by WRF are also highly sensitive to the urban canopy model (UCM) used. The implementation in this study of an improved UCM (the Princeton UCM or PUCM) that allows the simulation of heterogeneous urban facets and of key hydrological processes, together with the so-called CZ09 parameterization for the thermal roughness length, significantly reduce the bias (<1.5 °C) in the surface temperature fields as compared to satellite observations during daytime. The boundary layer potential temperature profiles are captured by WRF reasonable well at both urban and rural sites; the biases in these profiles relative to aircraft-mounted senor measurements are on the order of 1.5 °C. Changing UCMs and PBL schemes does not alter the performance of WRF in reproducing bulk boundary layer temperature profiles significantly. The results illustrate the wide range of urban environmental conditions that various configurations of WRF can produce, and the significant biases that should be assessed before inferences are made based on WRF outputs. The optimal set-up of WRF-PUCM developed in this paper also paves the way for a confident exploration of the city-scale impacts of UHI mitigation strategies in the companion paper (Li et al 2014). (letter)

  16. Resonance analysis of a high temperature piezoelectric disc for sensitivity characterization.

    Science.gov (United States)

    Bilgunde, Prathamesh N; Bond, Leonard J

    2018-07-01

    Ultrasonic transducers for high temperature (200 °C+) applications are a key enabling technology for advanced nuclear power systems and in a range of chemical and petro-chemical industries. Design, fabrication and optimization of such transducers using piezoelectric materials remains a challenge. In this work, experimental data-based analysis is performed to investigate the fundamental causal factors for the resonance characteristics of a piezoelectric disc at elevated temperatures. The effect of all ten temperature-dependent piezoelectric constants (ε 33 , ε 11 , d 33 , d 31 , d 15 , s 11 , s 12 , s 13 , s 33 , s 44 ) is studied numerically on both the radial and thickness mode resonances of a piezoelectric disc. A sensitivity index is defined to quantify the effect of each of the temperature-dependent coefficients on the resonance modes of the modified lead zirconium titanate disc. The temperature dependence of s 33 showed highest sensitivity towards the thickness resonance mode followed by ε 33 , s 11 , s 13 , s 12 , d 31 , d 33 , s 44 , ε 11 , and d 15 in the decreasing order of the sensitivity index. For radial resonance modes, the temperature dependence of ε 33 showed highest sensitivity index followed by s 11 , s 12 and d 31 coefficient. This numerical study demonstrates that the magnitude of d 33 is not the sole factor that affects the resonance characteristics of the piezoelectric disc at high temperatures. It appears that there exists a complex interplay between various temperature dependent piezoelectric coefficients that causes reduction in the thickness mode resonance frequencies which is found to be agreement in with the experimental data at an elevated temperature. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. High sensitivity fiber optic angular displacement sensor and its application for detection of ultrasound.

    Science.gov (United States)

    Sakamoto, João Marcos Salvi; Kitano, Cláudio; Pacheco, Gefeson Mendes; Tittmann, Bernhard Rainer

    2012-07-10

    In this paper, we report on the development of an intensity-modulated fiber-optic sensor for angular displacement measurement. This sensor was designed to present high sensitivity, linear response, and wide bandwidth and, furthermore, to be simple and low cost. The sensor comprises two optical fibers, a positive lens, a reflective surface, an optical source, and a photodetector. A mathematical model was developed to determine and simulate the static characteristic curve of the sensor and to compare different sensor configurations regarding the core radii of the optical fibers. The simulation results showed that the sensor configurations tested are highly sensitive to small angle variation (in the range of microradians) with nonlinearity less than or equal to 1%. The normalized sensitivity ranges from (0.25×V(max)) to (2.40×V(max)) mV/μrad (where V(max) is the peak voltage of the static characteristic curve), and the linear range is from 194 to 1840 μrad. The unnormalized sensitivity for a reflective surface with reflectivity of 100% was measured as 7.7 mV/μrad. The simulations were compared with experimental results to validate the mathematical model and to define the most suitable configuration for ultrasonic detection. The sensor was tested on the characterization of a piezoelectric transducer and as part of a laser ultrasonics setup. The velocities of the longitudinal, shear, and surface waves were measured on aluminum samples as 6.43, 3.17, and 2.96 mm/μs, respectively, with an error smaller than 1.3%. The sensor, an alternative to piezoelectric or interferometric detectors, proved to be suitable for detection of ultrasonic waves and to perform time-of-flight measurements and nondestructive inspection.

  18. Highly Sensitive Multifilament Fiber Strain Sensors with Ultrabroad Sensing Range for Textile Electronics.

    Science.gov (United States)

    Lee, Jaehong; Shin, Sera; Lee, Sanggeun; Song, Jaekang; Kang, Subin; Han, Heetak; Kim, SeulGee; Kim, Seunghoe; Seo, Jungmok; Kim, DaeEun; Lee, Taeyoon

    2018-05-22

    Highly stretchable fiber strain sensors are one of the most important components for various applications in wearable electronics, electronic textiles, and biomedical electronics. Herein, we present a facile approach for fabricating highly stretchable and sensitive fiber strain sensors by embedding Ag nanoparticles into a stretchable fiber with a multifilament structure. The multifilament structure and Ag-rich shells of the fiber strain sensor enable the sensor to simultaneously achieve both a high sensitivity and largely wide sensing range despite its simple fabrication process and components. The fiber strain sensor simultaneously exhibits ultrahigh gauge factors (∼9.3 × 10 5 and ∼659 in the first stretching and subsequent stretching, respectively), a very broad strain-sensing range (450 and 200% for the first and subsequent stretching, respectively), and high durability for more than 10 000 stretching cycles. The fiber strain sensors can also be readily integrated into a glove to control a hand robot and effectively applied to monitor the large volume expansion of a balloon and a pig bladder for an artificial bladder system, thereby demonstrating the potential of the fiber strain sensors as candidates for electronic textiles, wearable electronics, and biomedical engineering.

  19. A flexible and highly sensitive nonenzymatic glucose sensor based on DVD-laser scribed graphene substrate.

    Science.gov (United States)

    Lin, Songyue; Feng, Wendou; Miao, Xiaofei; Zhang, Xiangxin; Chen, Sujing; Chen, Yuanqiang; Wang, Wei; Zhang, Yining

    2018-07-01

    Flexible and implantable glucose biosensors are emerging technologies for continuous monitoring of blood-glucose of diabetes. Developing a flexible conductive substrates with high active surface area is critical for advancing the technology. Here, we successfully fabricate a flexible and highly sensitive nonenzymatic glucose by using DVD-laser scribed graphene (LSG) as a flexible conductively substrate. Copper nanoparticles (Cu-NPs) are electrodeposited as the catalyst. The LSG/Cu-NPs sensor demonstrates excellent catalytic activity toward glucose oxidation and exhibits a linear glucose detection range from 1 μM to 4.54 mM with high sensitivity (1.518 mA mM -1 cm -2 ) and low limit of detection (0.35 μM). Moreover, the LSG/Cu-NPs sensor shows excellent reproducibility and long-term stability. It is also highly selective toward glucose oxidation under the presence of various interfering species. Excellent flexing stability is also demonstrated by the LSG/Cu-NPs sensor, which is capable of maintaining 83.9% of its initial current after being bent against a 4-mm diameter rod for 180 times. The LSG/Cu-NPs sensor shows great potential for practical application as a nonenzymatic glucose biosensor. Meanwhile, the LSG conductive substrate provides a platform for the developing next-generation flexible and potentially implantable bioelectronics and biosensors. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. A virus-MIPs fluorescent sensor based on FRET for highly sensitive detection of JEV.

    Science.gov (United States)

    Liang, Caishuang; Wang, Huan; He, Kui; Chen, Chunyan; Chen, Xiaoming; Gong, Hang; Cai, Changqun

    2016-11-01

    Major stumbling blocks in the recognition and detection of virus are the unstable biological recognition element or the complex detection means. Here a fluorescent sensor based on virus-molecular imprinted polymers (virus-MIPs) was designed for specific recognition and highly sensitive detection of Japanese encephalitis virus (JEV). The virus-MIPs were anchored on the surface of silica microspheres modified by fluorescent dye, pyrene-1-carboxaldehyde (PC). The fluorescence intensity of PC can be enhanced by the principle of fluorescence resonance energy transfer (FRET), where virus acted as energy donor and PC acted as energy acceptor. The enhanced fluorescence intensity was proportional to the concentration of virus in the range of 24-960pM, with a limit of detection (LOD, 3σ) of 9.6pM, and the relative standard deviation was 1.99%. In additional, the specificity study confirmed the resultant MIPs has high-selectivity for JEV. This sensor would become a new key for the detection of virus because of its high sensitive, simple operation, high stability and low cost. Copyright © 2016. Published by Elsevier B.V.

  1. European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay.

    Science.gov (United States)

    Krintus, Magdalena; Kozinski, Marek; Boudry, Pascal; Capell, Nuria Estañ; Köller, Ursula; Lackner, Karl; Lefèvre, Guillaume; Lennartz, Lieselotte; Lotz, Johannes; Herranz, Antonio Mora; Nybo, Mads; Plebani, Mario; Sandberg, Maria B; Schratzberger, Wolfgang; Shih, Jessie; Skadberg, Øyvind; Chargui, Ahmed Taoufik; Zaninotto, Martina; Sypniewska, Grazyna

    2014-11-01

    International recommendations highlight the superior value of cardiac troponins (cTns) for early diagnosis of myocardial infarction along with analytical requirements of improved precision and detectability. In this multicenter study, we investigated the analytical performance of a new high sensitive cardiac troponin I (hs-cTnI) assay and its 99th percentile upper reference limit (URL). Laboratories from nine European countries evaluated the ARCHITECT STAT high sensitive troponin I (hs-TnI) immunoassay on the ARCHITECT i2000SR/i1000SR immunoanalyzers. Imprecision, limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ) linearity of dilution, interferences, sample type, method comparisons, and 99th percentile URLs were evaluated in this study. Total imprecision of 3.3%-8.9%, 2.0%-3.5% and 1.5%-5.2% was determined for the low, medium and high controls, respectively. The lowest cTnI concentration corresponding to a total CV of 10% was 5.6 ng/L. Common interferences, sample dilution and carryover did not affect the hs-cTnI results. Slight, but statistically significant, differences with sample type were found. Concordance between the investigated hs-cTnI assay and contemporary cTnI assay at 99th percentile cut-off was found to be 95%. TnI was detectable in 75% and 57% of the apparently healthy population using the lower (1.1 ng/L) and upper (1.9 ng/L) limit of the LoD range provided by the ARCHITECT STAT hs-TnI package insert, respectively. The 99th percentile values were gender dependent. The new ARCHITECT STAT hs-TnI assay with improved analytical features meets the criteria of high sensitive Tn test and will be a valuable diagnostic tool.

  2. Discovery and validation of a colorectal cancer classifier in a new blood test with improved performance for high-risk subjects

    DEFF Research Database (Denmark)

    Croner, Lisa J; Dillon, Roslyn; Kao, Athit

    2017-01-01

    BACKGROUND: The aim was to improve upon an existing blood-based colorectal cancer (CRC) test directed to high-risk symptomatic patients, by developing a new CRC classifier to be used with a new test embodiment. The new test uses a robust assay format-electrochemiluminescence immunoassays......, the indeterminate rate of the new panel was 23.2%, sensitivity/specificity was 0.80/0.83, PPV was 36.5%, and NPV was 97.1%. CONCLUSIONS: The validated classifier serves as the basis of a new blood-based CRC test for symptomatic patients. The improved performance, resulting from robust concentration measures across......-to quantify protein concentrations. The aim was achieved by building and validating a CRC classifier using concentration measures from a large sample set representing a true intent-to-test (ITT) symptomatic population. METHODS: 4435 patient samples were drawn from the Endoscopy II sample set. Samples were...

  3. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng, E-mail: fuzf@swu.edu.cn

    2014-08-11

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β{sub 2}-agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β{sub 2}-agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β{sub 2}-agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β{sub 2}-agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL{sup −1}, with the detection limits of 0.20 and 0.040 ng mL{sup −1} (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β{sub 2}-agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety.

  4. Eating high fat chow increases the sensitivity of rats to 8-OH-DPAT-induced lower lip retraction.

    Science.gov (United States)

    Li, Jun-Xu; Ju, Shutian; Baladi, Michelle G; Koek, Wouter; France, Charles P

    2011-12-01

    Eating high fat food can alter sensitivity to drugs acting on dopamine systems; this study examined whether eating high fat food alters sensitivity to a drug acting on serotonin (5-HT) systems. Sensitivity to (+)-8-hydroxy-2-(dipropylamino) tetralin hydrobromide (8-OH-DPAT; 5-HT1A receptor agonist)-induced lower lip retraction was examined in separate groups (n=8-9) of rats with free access to standard (5.7% fat) or high fat (34.3% fat) chow; sensitivity to quinpirole (dopamine D3/D2 receptor agonist)-induced yawning was also examined. Rats eating high fat chow gained more body weight than rats eating standard chow and, after 6 weeks of eating high fat chow, they were more sensitive to 8-OH-DPAT (0.01-0.1 mg/kg)-induced lower lip retraction and quinpirole (0.0032-0.32 mg/kg)-induced yawning. These changes were not reversed when rats that previously ate high fat chow were switched to eating standard chow and sensitivity to 8-OH-DPAT and quinpirole increased when rats that previously ate standard chow ate high fat chow. These data extend previous results showing changes in sensitivity to drugs acting on dopamine systems in animals eating high fat chow to a drug acting at 5-HT1A receptors and they provide support for the notion that eating certain foods impacts sensitivity to drugs acting on monoamine systems.

  5. High Sensitivity and High Detection Specificity of Gold-Nanoparticle-Grafted Nanostructured Silicon Mass Spectrometry for Glucose Analysis.

    Science.gov (United States)

    Tsao, Chia-Wen; Yang, Zhi-Jie

    2015-10-14

    Desorption/ionization on silicon (DIOS) is a high-performance matrix-free mass spectrometry (MS) analysis method that involves using silicon nanostructures as a matrix for MS desorption/ionization. In this study, gold nanoparticles grafted onto a nanostructured silicon (AuNPs-nSi) surface were demonstrated as a DIOS-MS analysis approach with high sensitivity and high detection specificity for glucose detection. A glucose sample deposited on the AuNPs-nSi surface was directly catalyzed to negatively charged gluconic acid molecules on a single AuNPs-nSi chip for MS analysis. The AuNPs-nSi surface was fabricated using two electroless deposition steps and one electroless etching step. The effects of the electroless fabrication parameters on the glucose detection efficiency were evaluated. Practical application of AuNPs-nSi MS glucose analysis in urine samples was also demonstrated in this study.

  6. An efficient protocol for the synthesis of highly sensitive indole imines utilizing green chemistry: optimization of reaction conditions.

    Science.gov (United States)

    Nisar, Bushra; Rubab, Syeda Laila; Raza, Abdul Rauf; Tariq, Sobia; Sultan, Ayesha; Tahir, Muhammad Nawaz

    2018-04-11

    Novel and highly sensitive indole-based imines have been synthesized. Their synthesis has been compared employing a variety of protocols. Ultimately, a convenient, economical and high yielding set of conditions employing green chemistry have been designed for their synthesis.

  7. Alcohol Recognition by Flexible, Transparent and Highly Sensitive Graphene-Based Thin-Film Sensors

    KAUST Repository

    Xu, Xuezhu

    2017-06-22

    Chemical sensors detect a variety of chemicals across numerous fields, such as automobile, aerospace, safety, indoor air quality, environmental control, food, industrial production and medicine. We successfully assemble an alcohol-sensing device comprising a thin-film sensor made of graphene nanosheets (GNs) and bacterial cellulose nanofibers (BCNs). We show that the GN/BCN sensor has a high selectivity to ethanol by distinguishing liquid-phase or vapor-phase ethanol (C2H6O) from water (H2O) intelligently with accurate transformation into electrical signals in devices. The BCN component of the film amplifies the ethanol sensitivity of the film, whereby the GN/BCN sensor has 12400% sensitivity for vapor-phase ethanol compared to the pure GN sensor, which has only 21% sensitivity. Finally, GN/BCN sensors demonstrate fast response/recovery times and a wide range of alcohol detection (10-100%). The superior sensing ability of GN/BCN compared to GNs alone is due to the improved wettability of BCNs and the ionization of liquids. We prove a facile, green, low-cost route for the assembly of ethanol-sensing devices with potential for vast application.

  8. Colorimetry and SERS dual-mode detection of telomerase activity: combining rapid screening with high sensitivity.

    Science.gov (United States)

    Zong, Shenfei; Wang, Zhuyuan; Chen, Hui; Hu, Guohua; Liu, Min; Chen, Peng; Cui, Yiping

    2014-01-01

    As an important biomarker and therapeutic target, telomerase has attracted considerable attention concerning its detection and monitoring. Here, we present a colorimetry and surface enhanced Raman scattering (SERS) dual-mode telomerase activity detection method, which has several distinctive advantages. First, colorimetric functionality allows rapid preliminary discrimination of telomerase activity by the naked eye. Second, the employment of SERS technique results in greatly improved detection sensitivity. Third, the combination of colorimetry and SERS into one detection system can ensure highly efficacious and sensitive screening of numerous samples. Besides, the avoidance of polymerase chain reaction (PCR) procedures further guarantees fine reliability and simplicity. Generally, the presented method is realized by an "elongate and capture" procedure. To be specific, gold nanoparticles modified with Raman molecules and telomeric repeat complementary oligonucleotide are employed as the colorimetric-SERS bifunctional reporting nanotag, while magnetic nanoparticles functionalized with telomerase substrate oligonucleotide are used as the capturing substrate. Telomerase can synthesize and elongate telomeric repeats onto the capturing substrate. The elongated telomeric repeats subsequently facilitate capturing of the reporting nanotag via hybridization between telomeric repeat and its complementary strand. The captured nanotags can cause a significant difference in the color and SERS intensity of the magnetically separated sediments. Thus both the color and SERS can be used as indicators of the telomerase activity. With fast screening ability and outstanding sensitivity, we anticipate that this method would greatly promote practical application of telomerase-based early-stage cancer diagnosis.

  9. Highly Sensitive Bacteriophage-Based Detection of Brucella abortus in Mixed Culture and Spiked Blood

    Directory of Open Access Journals (Sweden)

    Kirill V. Sergueev

    2017-06-01

    Full Text Available For decades, bacteriophages (phages have been used for Brucella species identification in the diagnosis and epidemiology of brucellosis. Traditional Brucella phage typing is a multi-day procedure including the isolation of a pure culture, a step that can take up to three weeks. In this study, we focused on the use of brucellaphages for sensitive detection of the pathogen in clinical and other complex samples, and developed an indirect method of Brucella detection using real-time quantitative PCR monitoring of brucellaphage DNA amplification via replication on live Brucella cells. This assay allowed the detection of single bacteria (down to 1 colony-forming unit per milliliter within 72 h without DNA extraction and purification steps. The technique was equally efficient with Brucella abortus pure culture and with mixed cultures of B. abortus and α-proteobacterial near neighbors that can be misidentified as Brucella spp., Ochrobactrum anthropi and Afipia felis. The addition of a simple short sample preparation step enabled the indirect phage-based detection of B. abortus in spiked blood, with the same high sensitivity. This indirect phage-based detection assay enables the rapid and sensitive detection of live B. abortus in mixed cultures and in blood samples, and can potentially be applied for detection in other clinical samples and other complex sample types.

  10. Highly Sensitive Bacteriophage-Based Detection of Brucella abortus in Mixed Culture and Spiked Blood.

    Science.gov (United States)

    Sergueev, Kirill V; Filippov, Andrey A; Nikolich, Mikeljon P

    2017-06-10

    For decades, bacteriophages (phages) have been used for Brucella species identification in the diagnosis and epidemiology of brucellosis. Traditional Brucella phage typing is a multi-day procedure including the isolation of a pure culture, a step that can take up to three weeks. In this study, we focused on the use of brucellaphages for sensitive detection of the pathogen in clinical and other complex samples, and developed an indirect method of Brucella detection using real-time quantitative PCR monitoring of brucellaphage DNA amplification via replication on live Brucella cells. This assay allowed the detection of single bacteria (down to 1 colony-forming unit per milliliter) within 72 h without DNA extraction and purification steps. The technique was equally efficient with Brucella abortus pure culture and with mixed cultures of B . abortus and α-proteobacterial near neighbors that can be misidentified as Brucella spp., Ochrobactrum anthropi and Afipia felis . The addition of a simple short sample preparation step enabled the indirect phage-based detection of B . abortus in spiked blood, with the same high sensitivity. This indirect phage-based detection assay enables the rapid and sensitive detection of live B . abortus in mixed cultures and in blood samples, and can potentially be applied for detection in other clinical samples and other complex sample types.

  11. Highly Sensitive Colorimetric Assay for Determining Fe3+ Based on Gold Nanoparticles Conjugated with Glycol Chitosan

    Directory of Open Access Journals (Sweden)

    Kyungmin Kim

    2017-01-01

    Full Text Available A highly sensitive and simple colorimetric assay for the detection of Fe3+ ions was developed using gold nanoparticles (AuNPs conjugated with glycol chitosan (GC. The Fe3+ ion coordinates with the oxygen atoms of GC in a hexadentate manner (O-Fe3+-O, decreasing the interparticle distance and inducing aggregation. Time-of-flight secondary ion mass spectrometry showed that the bound Fe3+ was coordinated to the oxygen atoms of the ethylene glycol in GC, which resulted in a significant color change from light red to dark midnight blue due to aggregation. Using this GC-AuNP probe, the quantitative determination of Fe3+ in biological, environmental, and pharmaceutical samples could be achieved by the naked eye and spectrophotometric methods. Sensitive response and pronounced color change of the GC-AuNPs in the presence of Fe3+ were optimized at pH 6, 70°C, and 300 mM NaCl concentration. The absorption intensity ratio (A700/A510 linearly correlated to the Fe3+ concentration in the linear range of 0–180 μM. The limits of detection were 11.3, 29.2, and 46.0 nM for tap water, pond water, and iron supplement tablets, respectively. Owing to its facile and sensitive nature, this assay method for Fe3+ ions can be applied to the analysis of drinking water and pharmaceutical samples.

  12. A highly sensitive, low-cost, wearable pressure sensor based on conductive hydrogel spheres

    KAUST Repository

    Tai, Yanlong

    2015-01-01

    Wearable pressure sensing solutions have promising future for practical applications in health monitoring and human/machine interfaces. Here, a highly sensitive, low-cost, wearable pressure sensor based on conductive single-walled carbon nanotube (SWCNT)/alginate hydrogel spheres is reported. Conductive and piezoresistive spheres are embedded between conductive electrodes (indium tin oxide-coated polyethylene terephthalate films) and subjected to environmental pressure. The detection mechanism is based on the piezoresistivity of the SWCNT/alginate conductive spheres and on the sphere-electrode contact. Step-by-step, we optimized the design parameters to maximize the sensitivity of the sensor. The optimized hydrogel sensor exhibited a satisfactory sensitivity (0.176 ΔR/R0/kPa-1) and a low detectable limit (10 Pa). Moreover, a brief response time (a few milliseconds) and successful repeatability were also demonstrated. Finally, the efficiency of this strategy was verified through a series of practical tests such as monitoring human wrist pulse, detecting throat muscle motion or identifying the location and the distribution of an external pressure using an array sensor (4 × 4). © 2015 The Royal Society of Chemistry.

  13. A Simple and Sensitive High-Content Assay for the Characterization of Antiproliferative Therapeutic Antibodies.

    Science.gov (United States)

    Stengl, Andreas; Hörl, David; Leonhardt, Heinrich; Helma, Jonas

    2017-03-01

    Monoclonal antibodies (mAbs) have become a central class of therapeutic agents in particular as antiproliferative compounds. Their often complex modes of action require sensitive assays during early, functional characterization. Current cell-based proliferation assays often detect metabolites that are indicative of metabolic activity but do not directly account for cell proliferation. Measuring DNA replication by incorporation of base analogues such as 5-bromo-2'-deoxyuridine (BrdU) fills this analytical gap but was previously restricted to bulk effect characterization in enzyme-linked immunosorbent assay formats. Here, we describe a cell-based assay format for the characterization of antiproliferative mAbs regarding potency and mode of action in a single experiment. The assay makes use of single cell-based high-content-analysis (HCA) for the reliable quantification of replicating cells and DNA content via 5-ethynyl-2'-deoxyuridine (EdU) and 4',6-diamidino-2-phenylindole (DAPI), respectively, as sensitive measures of antiproliferative mAb activity. We used trastuzumab, an antiproliferative therapeutic antibody interfering with HER2 cell surface receptor-mediated growth signal transduction, and HER2-overexpressing cell lines BT474 and SKBR3 to demonstrate up to 10-fold signal-to-background (S/B) ratios for treated versus untreated cells and a shift in cell cycle profiles indicating antibody-induced cell cycle arrest. The assay is simple, cost-effective, and sensitive, providing a cell-based format for preclinical characterization of therapeutic mAbs.

  14. A Novel High-Sensitivity, Low-Power, Liquid Crystal Temperature Sensor

    Directory of Open Access Journals (Sweden)

    José Francisco Algorri

    2014-04-01

    Full Text Available A novel temperature sensor based on nematic liquid crystal permittivity as a sensing magnitude, is presented. This sensor consists of a specific micrometric structure that gives considerable advantages from other previous related liquid crystal (LC sensors. The analytical study reveals that permittivity change with temperature is introduced in a hyperbolic cosine function, increasing the sensitivity term considerably. The experimental data has been obtained for ranges from −6 °C to 100 °C. Despite this, following the LC datasheet, theoretical ranges from −40 °C to 109 °C could be achieved. These results have revealed maximum sensitivities of 33 mVrms/°C for certain temperature ranges; three times more than of most silicon temperature sensors. As it was predicted by the analytical study, the micrometric size of the proposed structure produces a high output voltage. Moreover the voltage’s sensitivity to temperature response can be controlled by the applied voltage. This response allows temperature measurements to be carried out without any amplification or conditioning circuitry, with very low power consumption.

  15. Highly Sensitive Bacteriophage-Based Detection of Brucella abortus in Mixed Culture and Spiked Blood

    Science.gov (United States)

    Sergueev, Kirill V.; Filippov, Andrey A.; Nikolich, Mikeljon P.

    2017-01-01

    For decades, bacteriophages (phages) have been used for Brucella species identification in the diagnosis and epidemiology of brucellosis. Traditional Brucella phage typing is a multi-day procedure including the isolation of a pure culture, a step that can take up to three weeks. In this study, we focused on the use of brucellaphages for sensitive detection of the pathogen in clinical and other complex samples, and developed an indirect method of Brucella detection using real-time quantitative PCR monitoring of brucellaphage DNA amplification via replication on live Brucella cells. This assay allowed the detection of single bacteria (down to 1 colony-forming unit per milliliter) within 72 h without DNA extraction and purification steps. The technique was equally efficient with Brucella abortus pure culture and with mixed cultures of B. abortus and α-proteobacterial near neighbors that can be misidentified as Brucella spp., Ochrobactrum anthropi and Afipia felis. The addition of a simple short sample preparation step enabled the indirect phage-based detection of B. abortus in spiked blood, with the same high sensitivity. This indirect phage-based detection assay enables the rapid and sensitive detection of live B. abortus in mixed cultures and in blood samples, and can potentially be applied for detection in other clinical samples and other complex sample types. PMID:28604602

  16. A High Sensitivity IDC-Electronic Tongue Using Dielectric/Sensing Membranes with Solvatochromic Dyes

    Directory of Open Access Journals (Sweden)

    Md. Rajibur Rahaman Khan

    2016-05-01

    Full Text Available In this paper, an electronic tongue/taste sensor array containing different interdigitated capacitor (IDC sensing elements to detect different types of tastes, such as sweetness (glucose, saltiness (NaCl, sourness (HCl, bitterness (quinine-HCl, and umami (monosodium glutamate is proposed. We present for the first time an IDC electronic tongue using sensing membranes containing solvatochromic dyes. The proposed highly sensitive (30.64 mV/decade sensitivity IDC electronic tongue has fast response and recovery times of about 6 s and 5 s, respectively, with extremely stable responses, and is capable of linear sensing performance (R2 ≈ 0.985 correlation coefficient over the wide dynamic range of 1 µM to 1 M. The designed IDC electronic tongue offers excellent reproducibility, with a relative standard deviation (RSD of about 0.029. The proposed device was found to have better sensing performance than potentiometric-, cascoded compatible lateral bipolar transistor (C-CLBT-, Electronic Tongue (SA402-, and fiber-optic-based taste sensing systems in what concerns dynamic range width, response time, sensitivity, and linearity. Finally, we applied principal component analysis (PCA to distinguish between various kinds of taste in mixed taste compounds.

  17. Highly sensitive and selective cholesterol biosensor based on direct electron transfer of hemoglobin.

    Science.gov (United States)

    Zhao, Changzhi; Wan, Li; Jiang, Li; Wang, Qin; Jiao, Kui

    2008-12-01

    A cholesterol biosensor based on direct electron transfer of a hemoglobin-encapsulated chitosan-modified glassy carbon electrode has been developed for highly sensitive and selective analysis of serum samples. Modified by films containing hemoglobin and cholesterol oxidase, the electrode was prepared by encapsulation of enzyme in chitosan matrix. The hydrogen peroxide produced by the catalytic oxidation of cholesterol by cholesterol oxidase was reduced electrocatalytically by immobilized hemoglobin and used to obtain a sensitive amperometric response to cholesterol. The linear response of cholesterol concentrations ranged from 1.00 x 10(-5) to 6.00 x 10(-4) mol/L, with a correlation coefficient of 0.9969 and estimated detection limit of cholesterol of 9.5 micromol/L at a signal/noise ratio of 3. The cholesterol biosensor can efficiently exclude interference by the commonly coexisting ascorbic acid, uric acid, dopamine, and epinephrine. The sensitivity to the change in the concentration of cholesterol as the slope of the calibration curve was 0.596 A/M. The relative standard deviation was under 4.0% (n=5) for the determination of real samples. The biosensor is satisfactory in the determination of human serum samples.

  18. Global Sensitivity Analysis of High Speed Shaft Subsystem of a Wind Turbine Drive Train

    Directory of Open Access Journals (Sweden)

    Saeed Asadi

    2018-01-01

    Full Text Available The wind turbine dynamics are complex and critical area of study for the wind industry. Quantification of the effective factors to wind turbine performance is valuable for making improvements to both power performance and turbine health. In this paper, the global sensitivity analysis of validated mathematical model for high speed shaft drive train test rig has been developed in order to evaluate the contribution of systems input parameters to the specified objective functions. The drive train in this study consists of a 3-phase induction motor, flexible shafts, shafts’ coupling, bearing housing, and disk with an eccentric mass. The governing equations were derived by using the Lagrangian formalism and were solved numerically by Newmark method. The variance based global sensitivity indices are introduced to evaluate the contribution of input structural parameters correlated to the objective functions. The conclusion from the current research provides informative beneficial data in terms of design and optimization of a drive train setup and also can provide better understanding of wind turbine drive train system dynamics with respect to different structural parameters, ultimately designing more efficient drive trains. Finally, the proposed global sensitivity analysis (GSA methodology demonstrates the detectability of faults in different components.

  19. Sensitivity of boundary-layer stability to base-state distortions at high Mach numbers

    Science.gov (United States)

    Park, Junho; Zaki, Tamer

    2017-11-01

    The stability diagram of high-speed boundary layers has been established by evaluating the linear instability modes of the similarity profile, over wide ranges of Reynolds and Mach numbers. In real flows, however, the base state can deviate from the similarity profile. Both the base velocity and temperature can be distorted, for example due to roughness and thermal wall treatments. We review the stability problem of high-speed boundary layer, and derive a new formulation of the sensitivity to base-state distortion using forward and adjoint parabolized stability equations. The new formulation provides qualitative and quantitative interpretations on change in growth rate due to modifications of mean-flow and mean-temperature in heated high-speed boundary layers, and establishes the foundation for future control strategies. This work has been funded by the Air Force Office of Scientific Research (AFOSR) Grant: FA9550-16-1-0103.

  20. Piezoelectric Sensor to Measure Soft and Hard Stiffness with High Sensitivity for Ultrasonic Transducers

    Directory of Open Access Journals (Sweden)

    Yan-Rui Li

    2015-06-01

    Full Text Available During dental sinus lift surgery, it is important to monitor the thickness of the remaining maxilla to avoid perforating the sinus membrane. Therefore, a sensor should be integrated into ultrasonic dental tools to prevent undesirable damage. This paper presents a piezoelectric (PZT sensor installed in an ultrasonic transducer to measure the stiffness of high and low materials. Four design types using three PZT ring materials and a split PZT for actuator and sensor ring materials were studied. Three sensor locations were also examined. The voltage signals of the sensor and the displacement of the actuator were analyzed to distinguish the low and high stiffness. Using sensor type T1 made of the PZT-1 material and the front location A1 provided a high sensitivity of 2.47 Vm/kN. The experimental results demonstrated that our design can measure soft and hard stiffness.

  1. Insulin sensitivity is reduced in children with high body-fat regardless of BMI

    DEFF Research Database (Denmark)

    Fairchild, Timothy J; Klakk, Heidi; Heidemann, Malene

    2018-01-01

    BF% was measured by dual-energy X-ray absorptiometry (DXA). Fasting plasma glucose and insulin concentrations were measured and the homoeostatic model assessment of insulin resistance (HOMA-IR) used to assess insulin sensitivity. RESULTS: Approximately 8% of children classified as normal weight...... by BMI had high BF% (NW + Adipose). Children with high BF% had significantly higher insulin (NW + adipose: 32.3%; OW/OB + Adipose: 52.2%) and HOMA-IR scores (NW + Adipose: 32.3%; OW/OB + Adipose: 55.3%) than children classified as NW without high BF% (reference group; NW + NonAdipose). Adjusting for CRF...

  2. Interaural time sensitivity of high-frequency neurons in the inferior colliculus.

    Science.gov (United States)

    Yin, T C; Kuwada, S; Sujaku, Y

    1984-11-01

    Recent psychoacoustic experiments have shown that interaural time differences provide adequate cues for lateralizing high-frequency sounds, provided the stimuli are complex and not pure tones. We present here physiological evidence in support of these findings. Neurons of high best frequency in the cat inferior colliculus respond to interaural phase differences of amplitude modulated waveforms, and this response depends upon preservation of phase information of the modulating signal. Interaural phase differences were introduced in two ways: by interaural delays of the entire waveform and by binaural beats in which there was an interaural frequency difference in the modulating waveform. Results obtained with these two methods are similar. Our results show that high-frequency cells can respond to interaural time differences of amplitude modulated signals and that they do so by a sensitivity to interaural phase differences of the modulating waveform.

  3. Highly sensitive glucose sensor based on monodisperse palladium nickel/activated carbon nanocomposites.

    Science.gov (United States)

    Koskun, Yağmur; Şavk, Aysun; Şen, Betül; Şen, Fatih

    2018-06-20

    Glucose enzyme biosensors have been used for a variety of applications such as medical diagnosis, bioprocess engineering, beverage industry and environmental scanning etc. and there is still a growing interest in glucose sensors. For this purpose, addressed herein, as a novel glucose sensor, highly sensitive activated carbon (AC) decorated monodisperse nickel and palladium alloy nanocomposites modified glassy carbon electrode (Ni-Pd@AC/GCE NCs) have been synthesized by in-situ reduction technique. Raman Spectroscopy (RS), X-ray Photoelectron Spectroscopy (XPS), X-ray Diffraction (XRD), Transmission Electron Microscopy (TEM), cyclic voltammetry (CV) and chronoamperometry (CA) were used for the characterization of the prepared non-enzymatic glucose sensor. The characteristic sensor properties of the Ni-Pd@AC/GCE electrode were compared with Ni-Pd NCs/GCE, Ni@AC/GCE and Pd@AC/GCE and the results demonstrate that the AC is very effective in the enhancement of the electrocatalytic properties of sensor. In addition, the Ni-Pd@AC/GCE nanocomposites showed a very low detection limit of 0.014 μM, a wide linear range of 0.01 mM-1 mM and a very high sensitivity of 90 mA mM -1  cm -2 . Furthermore, the recommended sensor offer the various advantageous such as facile preparation, fast response time, high selectivity and sensitivity. Lastly, monodisperse Ni-Pd@AC/GCE was utilized to detect glucose in real sample species. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Molecular structure and thermodynamic predictions to create highly sensitive microRNA biosensors

    International Nuclear Information System (INIS)

    Larkey, Nicholas E.; Brucks, Corinne N.; Lansing, Shan S.; Le, Sophia D.; Smith, Natasha M.; Tran, Victoria; Zhang, Lulu; Burrows, Sean M.

    2016-01-01

    Many studies have established microRNAs (miRNAs) as post-transcriptional regulators in a variety of intracellular molecular processes. Abnormal changes in miRNA have been associated with several diseases. However, these changes are sometimes subtle and occur at nanomolar levels or lower. Several biosensing hurdles for in situ cellular/tissue analysis of miRNA limit detection of small amounts of miRNA. Of these limitations the most challenging are selectivity and sensor degradation creating high background signals and false signals. Recently we developed a reporter+probe biosensor for let-7a that showed potential to mitigate false signal from sensor degradation. Here we designed reporter+probe biosensors for miR-26a-2-3p and miR-27a-5p to better understand the effect of thermodynamics and molecular structures of the biosensor constituents on the analytical performance. Signal changes from interactions between Cy3 and Cy5 on the reporters were used to understand structural aspects of the reporter designs. Theoretical thermodynamic values, single stranded conformations, hetero- and homodimerization structures, and equilibrium concentrations of the reporters and probes were used to interpret the experimental observations. Studies of the sensitivity and selectivity revealed 5–9 nM detection limits in the presence and absence of interfering off-analyte miRNAs. These studies will aid in determining how to rationally design reporter+probe biosensors to overcome hurdles associated with highly sensitive miRNA biosensing. - Highlights: • Challenges facing highly sensitive miRNA biosensor designs are addressed. • Thermodynamic and molecular structure design metrics for reporter+probe biosensors are proposed. • The influence of ideal and non-ideal reporter hairpin structures on reporter+probe formation and signal change are discussed. • 5–9 nM limits of detection were observed with no interference from off-analytes.

  5. Molecular structure and thermodynamic predictions to create highly sensitive microRNA biosensors

    Energy Technology Data Exchange (ETDEWEB)

    Larkey, Nicholas E.; Brucks, Corinne N.; Lansing, Shan S.; Le, Sophia D.; Smith, Natasha M.; Tran, Victoria; Zhang, Lulu; Burrows, Sean M., E-mail: sean.burrows@oregonstate.edu

    2016-02-25

    Many studies have established microRNAs (miRNAs) as post-transcriptional regulators in a variety of intracellular molecular processes. Abnormal changes in miRNA have been associated with several diseases. However, these changes are sometimes subtle and occur at nanomolar levels or lower. Several biosensing hurdles for in situ cellular/tissue analysis of miRNA limit detection of small amounts of miRNA. Of these limitations the most challenging are selectivity and sensor degradation creating high background signals and false signals. Recently we developed a reporter+probe biosensor for let-7a that showed potential to mitigate false signal from sensor degradation. Here we designed reporter+probe biosensors for miR-26a-2-3p and miR-27a-5p to better understand the effect of thermodynamics and molecular structures of the biosensor constituents on the analytical performance. Signal changes from interactions between Cy3 and Cy5 on the reporters were used to understand structural aspects of the reporter designs. Theoretical thermodynamic values, single stranded conformations, hetero- and homodimerization structures, and equilibrium concentrations of the reporters and probes were used to interpret the experimental observations. Studies of the sensitivity and selectivity revealed 5–9 nM detection limits in the presence and absence of interfering off-analyte miRNAs. These studies will aid in determining how to rationally design reporter+probe biosensors to overcome hurdles associated with highly sensitive miRNA biosensing. - Highlights: • Challenges facing highly sensitive miRNA biosensor designs are addressed. • Thermodynamic and molecular structure design metrics for reporter+probe biosensors are proposed. • The influence of ideal and non-ideal reporter hairpin structures on reporter+probe formation and signal change are discussed. • 5–9 nM limits of detection were observed with no interference from off-analytes.

  6. Highly efficient and stable dye-sensitized solar cells based on nanographite/polypyrrole counter electrode

    International Nuclear Information System (INIS)

    Yue, Gentian; Zhang, Xin’an; Wang, Lei; Tan, Furui; Wu, Jihuai; Jiang, Qiwei; Lin, Jianming; Huang, Miaoliang; Lan, Zhang

    2014-01-01

    Graphical abstract: Much higher photovoltaic performance of dye-sensitized solar cell with nanographite/PPy counter electrode as well as that of Pt configuration device. - Highlights: • Pt-free dye-sensitized solar cells. • The nanographite/PPy composite film showed high catalytic activity as well as Pt electrode. • The enhanced catalytic activity was attributed to increased active sites. • The DSSC based on the nanographite/PPy electrode showed a high photovoltaic performance. - Abstract: Nanographite/polypyrrole (NG/PPy) composite film was successfully prepared via in situ polymerization on rigid fluorine-doped tin oxide substrate and served as counter electrode (CE) for dye-sensitized solar cells (DSSCs). The surface morphology and composition of the composite film were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), Raman spectra and Fourier transform infrared spectroscopy (FTIR). The electrochemical performance of the NG/PPy electrode was evaluated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The results of CV and EIS revealed that the NG/PPy electrode possessed excellent electrocatalytic activity for the reduction reaction of triiodide to iodide and low charge transfer resistance at the interface between electrolyte and CE, respectively. The DSSC assembled with the novel NG/PPy CE exhibited an enhanced power conversion efficiency of 7.40% under full sunlight illumination as comparing to that of the DSSC based on sputtered-Pt electrode. Thus, the NG/PPy CE could be premeditated as a promising alternative CE for low-cost and high- efficient DSSCs

  7. Immune Profiles to Predict Response to Desensitization Therapy in Highly HLA-Sensitized Kidney Transplant Candidates.

    Science.gov (United States)

    Yabu, Julie M; Siebert, Janet C; Maecker, Holden T

    2016-01-01

    Kidney transplantation is the most effective treatment for end-stage kidney disease. Sensitization, the formation of human leukocyte antigen (HLA) antibodies, remains a major barrier to successful kidney transplantation. Despite the implementation of desensitization strategies, many candidates fail to respond. Current progress is hindered by the lack of biomarkers to predict response and to guide therapy. Our objective was to determine whether differences in immune and gene profiles may help identify which candidates will respond to desensitization therapy. Single-cell mass cytometry by time-of-flight (CyTOF) phenotyping, gene arrays, and phosphoepitope flow cytometry were performed in a study of 20 highly sensitized kidney transplant candidates undergoing desensitization therapy. Responders to desensitization therapy were defined as 5% or greater decrease in cumulative calculated panel reactive antibody (cPRA) levels, and non-responders had 0% decrease in cPRA. Using a decision tree analysis, we found that a combination of transitional B cell and regulatory T cell (Treg) frequencies at baseline before initiation of desensitization therapy could distinguish responders from non-responders. Using a support vector machine (SVM) and longitudinal data, TRAF3IP3 transcripts and HLA-DR-CD38+CD4+ T cells could also distinguish responders from non-responders. Combining all assays in a multivariate analysis and elastic net regression model with 72 analytes, we identified seven that were highly interrelated and eleven that predicted response to desensitization therapy. Measuring baseline and longitudinal immune and gene profiles could provide a useful strategy to distinguish responders from non-responders to desensitization therapy. This study presents the integration of novel translational studies including CyTOF immunophenotyping in a multivariate analysis model that has potential applications to predict response to desensitization, select candidates, and personalize

  8. Highly sensitive uric acid biosensor based on individual zinc oxide micro/nanowires

    International Nuclear Information System (INIS)

    Zhao, Yanguang; Yan, Xiaoqin; Kang, Zhuo; Lin, Pei; Fang, Xiaofei; Lei, Yang; Ma, Siwei; Zhang, Yue

    2013-01-01

    We describe the use of individual zinc oxide (ZnO) micro/nanowires in an electrochemical biosensor for uric acid. The wires were synthesized by chemical vapor deposition and possess uniform morphology and high crystallinity as revealed by scanning electron microscopy, X-ray diffraction, and photoluminescence studies. The enzyme uricase was then immobilized on the surface of the ZnO micro/nanowires by physical adsorption, and this was proven by Raman spectroscopy and fluorescence microscopy. The resulting uric acid biosensor undergoes fast electron transfer between the active site of the enzyme and the surface of the electrode. It displays high sensitivity (89.74 μA cm −2 mM −1 ) and a wide linear analytical range (between 0.1 mM and 0.59 mM concentrations of uric acid). This study also demonstrates the potential of the use of individual ZnO micro/nanowires for the construction of highly sensitive nano-sized biosensors. (author)

  9. Electrochemistry-based approaches to low cost, high sensitivity, automated, multiplexed protein immunoassays for cancer diagnostics.

    Science.gov (United States)

    Dixit, Chandra K; Kadimisetty, Karteek; Otieno, Brunah A; Tang, Chi; Malla, Spundana; Krause, Colleen E; Rusling, James F

    2016-01-21

    Early detection and reliable diagnostics are keys to effectively design cancer therapies with better prognoses. The simultaneous detection of panels of biomarker proteins holds great promise as a general tool for reliable cancer diagnostics. A major challenge in designing such a panel is to decide upon a coherent group of biomarkers which have higher specificity for a given type of cancer. The second big challenge is to develop test devices to measure these biomarkers quantitatively with high sensitivity and specificity, such that there are no interferences from the complex serum or tissue matrices. Lastly, integrating all these tests into a technology that does not require exclusive training to operate, and can be used at point-of-care (POC) is another potential bottleneck in futuristic cancer diagnostics. In this article, we review electrochemistry-based tools and technologies developed and/or used in our laboratories to construct low-cost microfluidic protein arrays for the highly sensitive detection of a panel of cancer-specific biomarkers with high specificity which at the same time has the potential to be translated into POC applications.

  10. Sodium Chloride Crystal-Induced SERS Platform for Controlled Highly Sensitive Detection of Illicit Drugs.

    Science.gov (United States)

    Yu, Borong; Li, Pan; Zhou, Binbin; Tang, Xianghu; Li, Shaofei; Yang, Liangbao

    2018-04-03

    A sodium chloride crystal-driven spontaneous 'hot spot' structure was demonstrated as a SERS-active platform, to get reproducible SERS signals, and eliminate the need for mapping large areas, in comparison with solution phase testing. During the process of solvent evaporation, the crystals produced induced silver aggregates to assemble around themselves. The micro-scale crystals can also act as a template to obtain an optical position, such that the assembled hot area is conveniently located during SERS measurements. More importantly, the chloride ions added in colloids can also replace the citrate and on the surface of the silver sol, and further decrease the background interference. High quality SERS spectra from heroin, methamphetamine (MAMP), and cocaine have been obtained on the crystal-driven hot spot structure with high sensitivity and credible reproducibility. This approach can not only bring the nanoparticles to form plasmonic hot spots in a controlled way, and thus provide high sensitivity, but also potentially be explored as an active substrate for label-free detection of other illicit drugs or additives. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Development of a High-Sensitivity Wireless Accelerometer for Structural Health Monitoring.

    Science.gov (United States)

    Zhu, Li; Fu, Yuguang; Chow, Raymond; Spencer, Billie F; Park, Jong Woong; Mechitov, Kirill

    2018-01-17

    Structural health monitoring (SHM) is playing an increasingly important role in ensuring the safety of structures. A shift of SHM research away from traditional wired methods toward the use of wireless smart sensors (WSS) has been motivated by the attractive features of wireless smart sensor networks (WSSN). The progress achieved in Micro Electro-Mechanical System (MEMS) technologies and wireless data transmission, has extended the effectiveness and range of applicability of WSSNs. One of the most common sensors employed in SHM strategies is the accelerometer; however, most accelerometers in WSS nodes have inadequate resolution for measurement of the typical accelerations found in many SHM applications. In this study, a high-resolution and low-noise tri-axial digital MEMS accelerometer is incorporated in a next-generation WSS platform, the Xnode. In addition to meeting the acceleration sensing demands of large-scale civil infrastructure applications, this new WSS node provides powerful hardware and a robust software framework to enable edge computing that can deliver actionable information. Hardware and software integration challenges are presented, and the associate resolutions are discussed. The performance of the wireless accelerometer is demonstrated experimentally through comparison with high-sensitivity wired accelerometers. This new high-sensitivity wireless accelerometer will extend the use of WSSN to a broader class of SHM applications.

  12. Development of a High-Sensitivity Wireless Accelerometer for Structural Health Monitoring

    Science.gov (United States)

    Zhu, Li; Fu, Yuguang; Chow, Raymond; Spencer, Billie F.; Park, Jong Woong; Mechitov, Kirill

    2018-01-01

    Structural health monitoring (SHM) is playing an increasingly important role in ensuring the safety of structures. A shift of SHM research away from traditional wired methods toward the use of wireless smart sensors (WSS) has been motivated by the attractive features of wireless smart sensor networks (WSSN). The progress achieved in Micro Electro-Mechanical System (MEMS) technologies and wireless data transmission, has extended the effectiveness and range of applicability of WSSNs. One of the most common sensors employed in SHM strategies is the accelerometer; however, most accelerometers in WSS nodes have inadequate resolution for measurement of the typical accelerations found in many SHM applications. In this study, a high-resolution and low-noise tri-axial digital MEMS accelerometer is incorporated in a next-generation WSS platform, the Xnode. In addition to meeting the acceleration sensing demands of large-scale civil infrastructure applications, this new WSS node provides powerful hardware and a robust software framework to enable edge computing that can deliver actionable information. Hardware and software integration challenges are presented, and the associate resolutions are discussed. The performance of the wireless accelerometer is demonstrated experimentally through comparison with high-sensitivity wired accelerometers. This new high-sensitivity wireless accelerometer will extend the use of WSSN to a broader class of SHM applications. PMID:29342102

  13. A Monolithic CMOS Magnetic Hall Sensor with High Sensitivity and Linearity Characteristics

    Directory of Open Access Journals (Sweden)

    Haiyun Huang

    2015-10-01

    Full Text Available This paper presents a fully integrated linear Hall sensor by means of 0.8 μm high voltage complementary metal-oxide semiconductor (CMOS technology. This monolithic Hall sensor chip features a highly sensitive horizontal switched Hall plate and an efficient signal conditioner using dynamic offset cancellation technique. An improved cross-like Hall plate achieves high magnetic sensitivity and low offset. A new spinning current modulator stabilizes the quiescent output voltage and improves the reliability of the signal conditioner. The tested results show that at the 5 V supply voltage, the maximum Hall output voltage of the monolithic Hall sensor microsystem, is up to ±2.1 V and the linearity of Hall output voltage is higher than 99% in the magnetic flux density range from ±5 mT to ±175 mT. The output equivalent residual offset is 0.48 mT and the static power consumption is 20 mW.

  14. A hydrogel biosensor for high selective and sensitive detection of amyloid-beta oligomers.

    Science.gov (United States)

    Sun, Liping; Zhong, Yong; Gui, Jie; Wang, Xianwu; Zhuang, Xiaorong; Weng, Jian

    2018-01-01

    Alzheimer's disease (AD) is a neurodegenerative disorder characterized by progressive cognitive and memory impairment. It is the most common neurological disease that causes dementia. Soluble amyloid-beta oligomers (AβO) in blood or cerebrospinal fluid (CSF) are the pathogenic biomarker correlated with AD. A simple electrochemical biosensor using graphene oxide/gold nanoparticles (GNPs) hydrogel electrode was developed in this study. Thiolated cellular prion protein (PrP C ) peptide probe was immobilized on GNPs of the hydrogel electrode to construct an AβO biosensor. Electrochemical impedance spectroscopy was utilized for AβO analysis. The specific binding between AβO and PrP C probes on the hydrogel electrode resulted in an increase in the electron-transfer resistance. The biosensor showed high specificity and sensitivity for AβO detection. It could selectively differentiate AβO from amyloid-beta (Aβ) monomers or fibrils. Meanwhile, it was highly sensitive to detect as low as 0.1 pM AβO in artificial CSF or blood plasma. The linear range for AβO detection is from 0.1 pM to 10 nM. This biosensor could be used as a cost-effective tool for early diagnosis of AD due to its high electrochemical performance and bionic structure.

  15. High Sensitivity TSS Prediction: Estimates of Locations Where TSS Cannot Occur

    KAUST Repository

    Schaefer, Ulf

    2013-10-10

    Background Although transcription in mammalian genomes can initiate from various genomic positions (e.g., 3′UTR, coding exons, etc.), most locations on genomes are not prone to transcription initiation. It is of practical and theoretical interest to be able to estimate such collections of non-TSS locations (NTLs). The identification of large portions of NTLs can contribute to better focusing the search for TSS locations and thus contribute to promoter and gene finding. It can help in the assessment of 5′ completeness of expressed sequences, contribute to more successful experimental designs, as well as more accurate gene annotation. Methodology Using comprehensive collections of Cap Analysis of Gene Expression (CAGE) and other transcript data from mouse and human genomes, we developed a methodology that allows us, by performing computational TSS prediction with very high sensitivity, to annotate, with a high accuracy in a strand specific manner, locations of mammalian genomes that are highly unlikely to harbor transcription start sites (TSSs). The properties of the immediate genomic neighborhood of 98,682 accurately determined mouse and 113,814 human TSSs are used to determine features that distinguish genomic transcription initiation locations from those that are not likely to initiate transcription. In our algorithm we utilize various constraining properties of features identified in the upstream and downstream regions around TSSs, as well as statistical analyses of these surrounding regions. Conclusions Our analysis of human chromosomes 4, 21 and 22 estimates ~46%, ~41% and ~27% of these chromosomes, respectively, as being NTLs. This suggests that on average more than 40% of the human genome can be expected to be highly unlikely to initiate transcription. Our method represents the first one that utilizes high-sensitivity TSS prediction to identify, with high accuracy, large portions of mammalian genomes as NTLs. The server with our algorithm implemented is

  16. 3-d brownian motion simulator for high-sensitivity nanobiotechnological applications.

    Science.gov (United States)

    Toth, Arpád; Banky, Dániel; Grolmusz, Vince

    2011-12-01

    A wide variety of nanobiotechnologic applications are being developed for nanoparticle based in vitro diagnostic and imaging systems. Some of these systems make possible highly sensitive detection of molecular biomarkers. Frequently, the very low concentration of the biomarkers makes impossible the classical, partial differential equation-based mathematical simulation of the motion of the nanoparticles involved. We present a three-dimensional Brownian motion simulation tool for the prediction of the movement of nanoparticles in various thermal, viscosity, and geometric settings in a rectangular cuvette. For nonprofit users the server is freely available at the site http://brownian.pitgroup.org.

  17. A time resolving data acquisition system for multiple high-resolution position sensitive detectors

    International Nuclear Information System (INIS)

    Dimmler, D.G.

    1988-01-01

    An advanced time resolving data collection system for use in neutron and x-ray spectrometry has been implemented and put into routine operation. The system collects data from high-resolution position-sensitive area detectors with a maximum cumulative rate of 10/sup 6/ events per second. The events are sorted, in real-time, into many time-slice arrays. A programmable timing control unit allows for a wide choice of time sequences and time-slice array sizes. The shortest dwell time on a slice may be below 1 ms and the delay to switch between slices is zero

  18. Proposal of highly sensitive optofluidic sensors based on dispersive photonic crystal waveguides

    DEFF Research Database (Denmark)

    Xiao, Sanshui; Mortensen, Niels Asger

    2007-01-01

    Optofluidic sensors based on highly dispersive two-dimensional photonic crystal waveguides are studied theoretically. Results show that these structures are strongly sensitive to the refractive index of the infiltrated liquid (nl), which is used to tune dispersion of the photonic crystal waveguide....... The waveguide mode-gap edge shifts about 1.2 nm for δnl = 0.002. The shifts can be explained well by band structure theory combined with first-order perturbation theory. These devices are potentially interesting for chemical sensing applications....

  19. [Relationship between periodontitis and levels of high-sensitivity C-reactive protein].

    Science.gov (United States)

    Pan, Heng-biao; Chen, Hui; Zhou, Na; Jin, Dan; Zhang, Jing; Peng, Chun-mei

    2010-08-01

    To evaluate the relationship between periodontitis and the traditional risk factors of coronary heart disease (CHD), as well as the role in the mechanisms responsible for high-sensitivity C-reactive protein (hsCRP) in the relationship of peridontitis and CHD. A periodontal examination was conducted on a total of 356 subjects, and community periodontal index of treatment needs (CPITN) was obtained from each subject. Periodontal status was categorized into TN periodontal, hsCRP concentration and routinely CHD serological indexes. In the groups of TN periodontal pockets were found in the Group hsCRP > or = 3.0 mg x L(-1) (P periodontal disease.

  20. Highly Sensitive Fluorescence Probe Based on Functional SBA-15 for Selective Detection of Hg2+

    Directory of Open Access Journals (Sweden)

    Wang Xiaoyu

    2010-01-01

    Full Text Available Abstract An inorganic–organic hybrid fluorescence chemosensor (DA/SBA-15 was prepared by covalent immobilization of a dansylamide derivative into the channels of mesoporous silica material SBA-15 via (3-aminopropyltriethoxysilane (APTES groups. The primary hexagonally ordered mesoporous structure of SBA-15 was preserved after the grafting procedure. Fluorescence characterization shows that the obtained inorganic–organic hybrid composite is highly selective and sensitive to Hg2+ detection, suggesting the possibility for real-time qualitative or quantitative detection of Hg2+ and the convenience for potential application in toxicology and environmental science.