WorldWideScience

Sample records for highest accuracy auc

  1. Estimation of AUC or Partial AUC under Test-Result-Dependent Sampling.

    Science.gov (United States)

    Wang, Xiaofei; Ma, Junling; George, Stephen; Zhou, Haibo

    2012-01-01

    The area under the ROC curve (AUC) and partial area under the ROC curve (pAUC) are summary measures used to assess the accuracy of a biomarker in discriminating true disease status. The standard sampling approach used in biomarker validation studies is often inefficient and costly, especially when ascertaining the true disease status is costly and invasive. To improve efficiency and reduce the cost of biomarker validation studies, we consider a test-result-dependent sampling (TDS) scheme, in which subject selection for determining the disease state is dependent on the result of a biomarker assay. We first estimate the test-result distribution using data arising from the TDS design. With the estimated empirical test-result distribution, we propose consistent nonparametric estimators for AUC and pAUC and establish the asymptotic properties of the proposed estimators. Simulation studies show that the proposed estimators have good finite sample properties and that the TDS design yields more efficient AUC and pAUC estimates than a simple random sampling (SRS) design. A data example based on an ongoing cancer clinical trial is provided to illustrate the TDS design and the proposed estimators. This work can find broad applications in design and analysis of biomarker validation studies.

  2. NCC-AUC: an AUC optimization method to identify multi-biomarker panel for cancer prognosis from genomic and clinical data.

    Science.gov (United States)

    Zou, Meng; Liu, Zhaoqi; Zhang, Xiang-Sun; Wang, Yong

    2015-10-15

    In prognosis and survival studies, an important goal is to identify multi-biomarker panels with predictive power using molecular characteristics or clinical observations. Such analysis is often challenged by censored, small-sample-size, but high-dimensional genomic profiles or clinical data. Therefore, sophisticated models and algorithms are in pressing need. In this study, we propose a novel Area Under Curve (AUC) optimization method for multi-biomarker panel identification named Nearest Centroid Classifier for AUC optimization (NCC-AUC). Our method is motived by the connection between AUC score for classification accuracy evaluation and Harrell's concordance index in survival analysis. This connection allows us to convert the survival time regression problem to a binary classification problem. Then an optimization model is formulated to directly maximize AUC and meanwhile minimize the number of selected features to construct a predictor in the nearest centroid classifier framework. NCC-AUC shows its great performance by validating both in genomic data of breast cancer and clinical data of stage IB Non-Small-Cell Lung Cancer (NSCLC). For the genomic data, NCC-AUC outperforms Support Vector Machine (SVM) and Support Vector Machine-based Recursive Feature Elimination (SVM-RFE) in classification accuracy. It tends to select a multi-biomarker panel with low average redundancy and enriched biological meanings. Also NCC-AUC is more significant in separation of low and high risk cohorts than widely used Cox model (Cox proportional-hazards regression model) and L1-Cox model (L1 penalized in Cox model). These performance gains of NCC-AUC are quite robust across 5 subtypes of breast cancer. Further in an independent clinical data, NCC-AUC outperforms SVM and SVM-RFE in predictive accuracy and is consistently better than Cox model and L1-Cox model in grouping patients into high and low risk categories. In summary, NCC-AUC provides a rigorous optimization framework to

  3. CA-125 AUC as a predictor for epithelial ovarian cancer relapse.

    Science.gov (United States)

    Mano, António; Falcão, Amílcar; Godinho, Isabel; Santos, Jorge; Leitão, Fátima; de Oliveira, Carlos; Caramona, Margarida

    2008-01-01

    The aim of the present work was to evaluate the usefulness of CA-125 normalized in time area under the curve (CA-125 AUC) to signalise epithelial ovarian cancer relapse. Data from a hundred and eleven patients were submitted to two different approaches based on CA-125 AUC increase values to predict patient relapse. In Criterion A total CA-125 AUC normalized in time value (AUC(i)) was compared with the immediately previous one (AUC(i-1)) using the formulae AUC(i) > or = F * AUC(i-1) (several F values were tested) to find the appropriate close related increment associated to patient relapse. In Criterion B total CA-125 AUC normalised in time was calculated and several cut-off values were correlated with patient relapse prediction capacity. In Criterion A the best accuracy was achieved with a factor (F) of 1.25 (increment of 25% from the previous status), while in Criterion B the best accuracies were achieved with cut-offs of 25, 50, 75 and 100 IU/mL. The mean lead time to relapse achieved with Criterion A was 181 days, while with Criterion B they were, respectively, 131, 111, 63 and 11 days. Based on our results we believe that conjugation and sequential application of both criteria in patient relapse detection should be highly advisable. CA-125 AUC rapid burst in asymptomatic patients should be firstly evaluated using Criterion A with a high accuracy (0.85) and with a substantial mean lead time to relapse (181 days). If a negative answer was obtained then Criterion B should performed to confirm the absence of relapse.

  4. Severity of Carpal Tunnel Syndrome and Diagnostic Accuracy of Hand and Body Anthropometric Measures.

    Directory of Open Access Journals (Sweden)

    Mauro Mondelli

    Full Text Available To study the diagnostic properties of hand/wrist and body measures according to validated clinical and electrophysiological carpal tunnel syndrome (CTS severity scales.We performed a prospective case-control study. For each case, two controls were enrolled. Two five-stage clinical and electrophysiological scales were used to evaluate CTS severity. Anthropometric measurements were collected and obesity indicators and hand/wrist ratios were calculated. Area under the receiver operating characteristic curves (AUC, sensitivity, specificity, and likelihood ratios were calculated separately by gender.We consecutively enrolled 370 cases and 747 controls. The wrist-palm ratio, waist-hip-height ratio and waist-stature ratio showed the highest proportion of cases with abnormal values in the severe stages of CTS for clinical and electrophysiological severity scales in both genders. Accuracy tended to increase with CTS severity for females and males. In severe stage, most of the indexes presented moderate accuracy in both genders. Among subjects with severe CTS, the wrist-palm ratio presented the highest AUC for hand measures in the clinical and electrophysiological severity scales both in females (AUC 0.83 and 0.76, respectively and males (AUC 0.91 and 0.82, respectively. Among subjects with severe CTS, the waist-stature ratio showed the highest AUC for body measures in the clinical and electrophysiological severity scales both in females (AUC 0.78 and 0.77, respectively and males (AUC 0.84 and 0.76, respectively. The results of waist-hip-height ratio AUC were similar.Wrist-palm ratio, waist-hip-height ratio and waist-stature ratio could contribute to support the diagnostic hypothesis of severe CTS that however has to be confirmed by nerve conduction study.

  5. Severity of Carpal Tunnel Syndrome and Diagnostic Accuracy of Hand and Body Anthropometric Measures

    Science.gov (United States)

    Mondelli, Mauro; Farioli, Andrea; Mattioli, Stefano; Aretini, Alessandro; Ginanneschi, Federica; Greco, Giuseppe; Curti, Stefania

    2016-01-01

    Objective To study the diagnostic properties of hand/wrist and body measures according to validated clinical and electrophysiological carpal tunnel syndrome (CTS) severity scales. Methods We performed a prospective case-control study. For each case, two controls were enrolled. Two five-stage clinical and electrophysiological scales were used to evaluate CTS severity. Anthropometric measurements were collected and obesity indicators and hand/wrist ratios were calculated. Area under the receiver operating characteristic curves (AUC), sensitivity, specificity, and likelihood ratios were calculated separately by gender. Results We consecutively enrolled 370 cases and 747 controls. The wrist-palm ratio, waist-hip-height ratio and waist-stature ratio showed the highest proportion of cases with abnormal values in the severe stages of CTS for clinical and electrophysiological severity scales in both genders. Accuracy tended to increase with CTS severity for females and males. In severe stage, most of the indexes presented moderate accuracy in both genders. Among subjects with severe CTS, the wrist-palm ratio presented the highest AUC for hand measures in the clinical and electrophysiological severity scales both in females (AUC 0.83 and 0.76, respectively) and males (AUC 0.91 and 0.82, respectively). Among subjects with severe CTS, the waist-stature ratio showed the highest AUC for body measures in the clinical and electrophysiological severity scales both in females (AUC 0.78 and 0.77, respectively) and males (AUC 0.84 and 0.76, respectively). The results of waist-hip-height ratio AUC were similar. Conclusions Wrist-palm ratio, waist-hip-height ratio and waist-stature ratio could contribute to support the diagnostic hypothesis of severe CTS that however has to be confirmed by nerve conduction study. PMID:27768728

  6. Accuracy of Four Imaging Techniques for Diagnosis of Posterior Pelvic Floor Disorders.

    Science.gov (United States)

    van Gruting, Isabelle M A; Stankiewicz, Aleksandra; Kluivers, Kirsten; De Bin, Riccardo; Blake, Helena; Sultan, Abdul H; Thakar, Ranee

    2017-11-01

    To establish the diagnostic test accuracy of evacuation proctography, magnetic resonance imaging (MRI), transperineal ultrasonography, and endovaginal ultrasonography for detecting posterior pelvic floor disorders (rectocele, enterocele, intussusception, and anismus) in women with obstructed defecation syndrome and secondarily to identify the most patient-friendly imaging technique. In this prospective cohort study, 131 women with symptoms of obstructed defecation syndrome underwent evacuation proctogram, MRI, and transperineal and endovaginal ultrasonography. Images were analyzed by two blinded observers. In the absence of a reference standard, latent class analysis was used to assess diagnostic test accuracy of multiple tests with area under the curve (AUC) as the primary outcome measure. Secondary outcome measures were interobserver agreement calculated as Cohen's κ and patient acceptability using a visual analog scale. No significant differences in diagnostic accuracy were found among the imaging techniques for all the target conditions. Estimates of diagnostic test accuracy were highest for rectocele using MRI (AUC 0.79) or transperineal ultrasonography (AUC 0.85), for enterocele using transperineal (AUC 0.73) or endovaginal ultrasonography (AUC 0.87), for intussusception using evacuation proctography (AUC 0.76) or endovaginal ultrasonography (AUC 0.77), and for anismus using endovaginal (AUC 0.95) or transperineal ultrasonography (AUC 0.78). Interobserver agreement for the diagnosis of rectocele (κ 0.53-0.72), enterocele (κ 0.54-0.94) and anismus (κ 0.43-0.81) was moderate to excellent, but poor to fair for intussusception (κ -0.03 to 0.37) with all techniques. Patient acceptability was better for transperineal and endovaginal ultrasonography as compared with MRI and evacuation proctography (P<.001). Evacuation proctography, MRI, and transperineal and endovaginal ultrasonography were shown to have similar diagnostic test accuracy. Evacuation proctography

  7. Vancomycin AUC/MIC and Corresponding Troughs in a Pediatric Population.

    Science.gov (United States)

    Kishk, Omayma A; Lardieri, Allison B; Heil, Emily L; Morgan, Jill A

    2017-01-01

    Adult guidelines suggest an area under the curve/minimum inhibitory concentration (AUC/MIC) > 400 corresponds to a vancomycin trough serum concentration of 15 to 20 mg/L for methicillin-resistant Staphylococcus aureus infections, but obtaining these troughs in children are difficult. The primary objective of this study was to assess the likelihood that 15 mg/kg of vancomycin every 6 hours in a child achieves an AUC/MIC > 400. This retrospective chart review included pediatric patients >2 months to AUCs were calculated four times using three pharmacokinetic methods. A total of 36 patients with 99 vancomycin trough serum concentrations were assessed. Baseline characteristics were similar between groups. For troughs in group 1 (n = 55), the probability of achieving an AUC/MIC > 400 ranged from 16.4% to 90.9% with a median trough concentration of 11.4 mg/L, while in group 2 (n = 44) the probability of achieving AUC/MIC > 400 ranged from 15.9% to 54.5% with mean trough concentration of 9.2 mg/L. The AUC/MICs were not similar between the different pharmacokinetic methods used; however, a trapezoidal equation (Method A) yielded the highest correlation coefficient (r 2 = 0.59). When dosing every 6 hours, an AUC/MIC of 400 correlated to a trough serum concentration of 11 mg/L. The probability of achieving an AUC/MIC > 400 using only a trough serum concentration and an MIC with patients receiving 15 mg/kg every 6 hours is variable based on the method used to calculate the AUC. An AUC/MIC of 400 in children correlated to a trough concentration of 11 mg/L using a trapezoidal Method to calculate AUC.

  8. Evaluation of a Novel Glucose Area Under the Curve (AUC Monitoring System: Comparison with the AUC by Continuous Glucose Monitoring

    Directory of Open Access Journals (Sweden)

    Satoshi Ugi

    2016-07-01

    Full Text Available BackgroundManagement of postprandial hyperglycemia is a key aspect in diabetes treatment. We developed a novel system to measure glucose area under the curve (AUC using minimally invasive interstitial fluid extraction technology (MIET for simple monitoring of postprandial glucose excursions. In this study, we evaluated the relationship between our system and continuous glucose monitoring (CGM by comparing glucose AUC obtained using MIET with that obtained using CGM for a long duration.MethodsTwenty diabetic inpatients wearing a CGM system were enrolled. For MIET measurement, a plastic microneedle array was applied to the skin as pretreatment, and hydrogels were placed on the pretreated area to collect interstitial fluid. Hydrogels were replaced every 2 or 4 hours and AUC was predicted on the basis of glucose and sodium ion levels.ResultsAUC predicted by MIET correlated well with that measured by CGM (r=0.93. Good performances of both consecutive 2- and 4-hour measurements were observed (measurement error: 11.7%±10.2% for 2 hours and 11.1%±7.9% for 4 hours, indicating the possibility of repetitive measurements up to 8 hours. The influence of neither glucose fluctuation nor average glucose level over the measurement accuracy was observed through 8 hours.ConclusionOur system showed good relationship with AUC values from CGM up to 8 hours, indicating that single pretreatment can cover a large portion of glucose excursion in a day. These results indicated possibility of our system to contribute to convenient monitoring of glucose excursions for a long duration.

  9. Evaluation of a Novel Glucose Area Under the Curve (AUC) Monitoring System: Comparison with the AUC by Continuous Glucose Monitoring.

    Science.gov (United States)

    Ugi, Satoshi; Maegawa, Hiroshi; Morino, Katsutaro; Nishio, Yoshihiko; Sato, Toshiyuki; Okada, Seiki; Kikkawa, Yasuo; Watanabe, Toshihiro; Nakajima, Hiromu; Kashiwagi, Atsunori

    2016-08-01

    Management of postprandial hyperglycemia is a key aspect in diabetes treatment. We developed a novel system to measure glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET) for simple monitoring of postprandial glucose excursions. In this study, we evaluated the relationship between our system and continuous glucose monitoring (CGM) by comparing glucose AUC obtained using MIET with that obtained using CGM for a long duration. Twenty diabetic inpatients wearing a CGM system were enrolled. For MIET measurement, a plastic microneedle array was applied to the skin as pretreatment, and hydrogels were placed on the pretreated area to collect interstitial fluid. Hydrogels were replaced every 2 or 4 hours and AUC was predicted on the basis of glucose and sodium ion levels. AUC predicted by MIET correlated well with that measured by CGM (r=0.93). Good performances of both consecutive 2- and 4-hour measurements were observed (measurement error: 11.7%±10.2% for 2 hours and 11.1%±7.9% for 4 hours), indicating the possibility of repetitive measurements up to 8 hours. The influence of neither glucose fluctuation nor average glucose level over the measurement accuracy was observed through 8 hours. Our system showed good relationship with AUC values from CGM up to 8 hours, indicating that single pretreatment can cover a large portion of glucose excursion in a day. These results indicated possibility of our system to contribute to convenient monitoring of glucose excursions for a long duration.

  10. AUC-Maximized Deep Convolutional Neural Fields for Protein Sequence Labeling.

    Science.gov (United States)

    Wang, Sheng; Sun, Siqi; Xu, Jinbo

    2016-09-01

    Deep Convolutional Neural Networks (DCNN) has shown excellent performance in a variety of machine learning tasks. This paper presents Deep Convolutional Neural Fields (DeepCNF), an integration of DCNN with Conditional Random Field (CRF), for sequence labeling with an imbalanced label distribution. The widely-used training methods, such as maximum-likelihood and maximum labelwise accuracy, do not work well on imbalanced data. To handle this, we present a new training algorithm called maximum-AUC for DeepCNF. That is, we train DeepCNF by directly maximizing the empirical Area Under the ROC Curve (AUC), which is an unbiased measurement for imbalanced data. To fulfill this, we formulate AUC in a pairwise ranking framework, approximate it by a polynomial function and then apply a gradient-based procedure to optimize it. Our experimental results confirm that maximum-AUC greatly outperforms the other two training methods on 8-state secondary structure prediction and disorder prediction since their label distributions are highly imbalanced and also has similar performance as the other two training methods on solvent accessibility prediction, which has three equally-distributed labels. Furthermore, our experimental results show that our AUC-trained DeepCNF models greatly outperform existing popular predictors of these three tasks. The data and software related to this paper are available at https://github.com/realbigws/DeepCNF_AUC.

  11. AUC-Maximizing Ensembles through Metalearning.

    Science.gov (United States)

    LeDell, Erin; van der Laan, Mark J; Petersen, Maya

    2016-05-01

    Area Under the ROC Curve (AUC) is often used to measure the performance of an estimator in binary classification problems. An AUC-maximizing classifier can have significant advantages in cases where ranking correctness is valued or if the outcome is rare. In a Super Learner ensemble, maximization of the AUC can be achieved by the use of an AUC-maximining metalearning algorithm. We discuss an implementation of an AUC-maximization technique that is formulated as a nonlinear optimization problem. We also evaluate the effectiveness of a large number of different nonlinear optimization algorithms to maximize the cross-validated AUC of the ensemble fit. The results provide evidence that AUC-maximizing metalearners can, and often do, out-perform non-AUC-maximizing metalearning methods, with respect to ensemble AUC. The results also demonstrate that as the level of imbalance in the training data increases, the Super Learner ensemble outperforms the top base algorithm by a larger degree.

  12. The Open AUC Project.

    Science.gov (United States)

    Cölfen, Helmut; Laue, Thomas M; Wohlleben, Wendel; Schilling, Kristian; Karabudak, Engin; Langhorst, Bradley W; Brookes, Emre; Dubbs, Bruce; Zollars, Dan; Rocco, Mattia; Demeler, Borries

    2010-02-01

    Progress in analytical ultracentrifugation (AUC) has been hindered by obstructions to hardware innovation and by software incompatibility. In this paper, we announce and outline the Open AUC Project. The goals of the Open AUC Project are to stimulate AUC innovation by improving instrumentation, detectors, acquisition and analysis software, and collaborative tools. These improvements are needed for the next generation of AUC-based research. The Open AUC Project combines on-going work from several different groups. A new base instrument is described, one that is designed from the ground up to be an analytical ultracentrifuge. This machine offers an open architecture, hardware standards, and application programming interfaces for detector developers. All software will use the GNU Public License to assure that intellectual property is available in open source format. The Open AUC strategy facilitates collaborations, encourages sharing, and eliminates the chronic impediments that have plagued AUC innovation for the last 20 years. This ultracentrifuge will be equipped with multiple and interchangeable optical tracks so that state-of-the-art electronics and improved detectors will be available for a variety of optical systems. The instrument will be complemented by a new rotor, enhanced data acquisition and analysis software, as well as collaboration software. Described here are the instrument, the modular software components, and a standardized database that will encourage and ease integration of data analysis and interpretation software.

  13. Optimal Combinations of Diagnostic Tests Based on AUC.

    Science.gov (United States)

    Huang, Xin; Qin, Gengsheng; Fang, Yixin

    2011-06-01

    When several diagnostic tests are available, one can combine them to achieve better diagnostic accuracy. This article considers the optimal linear combination that maximizes the area under the receiver operating characteristic curve (AUC); the estimates of the combination's coefficients can be obtained via a nonparametric procedure. However, for estimating the AUC associated with the estimated coefficients, the apparent estimation by re-substitution is too optimistic. To adjust for the upward bias, several methods are proposed. Among them the cross-validation approach is especially advocated, and an approximated cross-validation is developed to reduce the computational cost. Furthermore, these proposed methods can be applied for variable selection to select important diagnostic tests. The proposed methods are examined through simulation studies and applications to three real examples. © 2010, The International Biometric Society.

  14. Guidance to Achieve Accurate Aggregate Quantitation in Biopharmaceuticals by SV-AUC.

    Science.gov (United States)

    Arthur, Kelly K; Kendrick, Brent S; Gabrielson, John P

    2015-01-01

    The levels and types of aggregates present in protein biopharmaceuticals must be assessed during all stages of product development, manufacturing, and storage of the finished product. Routine monitoring of aggregate levels in biopharmaceuticals is typically achieved by size exclusion chromatography (SEC) due to its high precision, speed, robustness, and simplicity to operate. However, SEC is error prone and requires careful method development to ensure accuracy of reported aggregate levels. Sedimentation velocity analytical ultracentrifugation (SV-AUC) is an orthogonal technique that can be used to measure protein aggregation without many of the potential inaccuracies of SEC. In this chapter, we discuss applications of SV-AUC during biopharmaceutical development and how characteristics of the technique make it better suited for some applications than others. We then discuss the elements of a comprehensive analytical control strategy for SV-AUC. Successful implementation of these analytical control elements ensures that SV-AUC provides continued value over the long time frames necessary to bring biopharmaceuticals to market. © 2015 Elsevier Inc. All rights reserved.

  15. AucPR: an AUC-based approach using penalized regression for disease prediction with high-dimensional omics data.

    Science.gov (United States)

    Yu, Wenbao; Park, Taesung

    2014-01-01

    It is common to get an optimal combination of markers for disease classification and prediction when multiple markers are available. Many approaches based on the area under the receiver operating characteristic curve (AUC) have been proposed. Existing works based on AUC in a high-dimensional context depend mainly on a non-parametric, smooth approximation of AUC, with no work using a parametric AUC-based approach, for high-dimensional data. We propose an AUC-based approach using penalized regression (AucPR), which is a parametric method used for obtaining a linear combination for maximizing the AUC. To obtain the AUC maximizer in a high-dimensional context, we transform a classical parametric AUC maximizer, which is used in a low-dimensional context, into a regression framework and thus, apply the penalization regression approach directly. Two kinds of penalization, lasso and elastic net, are considered. The parametric approach can avoid some of the difficulties of a conventional non-parametric AUC-based approach, such as the lack of an appropriate concave objective function and a prudent choice of the smoothing parameter. We apply the proposed AucPR for gene selection and classification using four real microarray and synthetic data. Through numerical studies, AucPR is shown to perform better than the penalized logistic regression and the nonparametric AUC-based method, in the sense of AUC and sensitivity for a given specificity, particularly when there are many correlated genes. We propose a powerful parametric and easily-implementable linear classifier AucPR, for gene selection and disease prediction for high-dimensional data. AucPR is recommended for its good prediction performance. Beside gene expression microarray data, AucPR can be applied to other types of high-dimensional omics data, such as miRNA and protein data.

  16. Different truncation methods of AUC between Japan and the EU for bioequivalence assessment: influence on the regulatory judgment.

    Science.gov (United States)

    Oishi, Masayo; Chiba, Koji; Fukushima, Takashi; Tomono, Yoshiro; Suwa, Toshio

    2012-01-01

    In regulatory guidelines for bioequivalence (BE) assessment, the definitions of AUC for primary assessment are different in ICH countries, i.e., AUC from zero to the last sampling point (AUCall) in Japan, AUC from zero to infinity (AUCinf) or AUC from zero to the last measurable point (AUClast) in the US, and AUClast in the EU. To assure sufficient accuracy of truncated AUC for BE assessment, the ratio of truncated AUC (AUCall or AUClast) to AUCinf should be more than 80% both in Japanese and EU guidelines. We investigated how the difference in the definition of truncated AUC affects BE assessment of sustained release (SR) formulation. Our simulation result demonstrated that AUCall/AUCinf could be ≥80% despite AUClast/AUCinf being AUC affected the judgment of validity of truncated AUC for BE assessment, and AUCall could fail to detect the substantially different in vivo dissolution profile of generic drugs with SR formulation from the original drug.

  17. AucPR: An AUC-based approach using penalized regression for disease prediction with high-dimensional omics data

    OpenAIRE

    Yu, Wenbao; Park, Taesung

    2014-01-01

    Motivation It is common to get an optimal combination of markers for disease classification and prediction when multiple markers are available. Many approaches based on the area under the receiver operating characteristic curve (AUC) have been proposed. Existing works based on AUC in a high-dimensional context depend mainly on a non-parametric, smooth approximation of AUC, with no work using a parametric AUC-based approach, for high-dimensional data. Results We propose an AUC-based approach u...

  18. Correcting AUC for Measurement Error.

    Science.gov (United States)

    Rosner, Bernard; Tworoger, Shelley; Qiu, Weiliang

    2015-12-01

    Diagnostic biomarkers are used frequently in epidemiologic and clinical work. The ability of a diagnostic biomarker to discriminate between subjects who develop disease (cases) and subjects who do not (controls) is often measured by the area under the receiver operating characteristic curve (AUC). The diagnostic biomarkers are usually measured with error. Ignoring measurement error can cause biased estimation of AUC, which results in misleading interpretation of the efficacy of a diagnostic biomarker. Several methods have been proposed to correct AUC for measurement error, most of which required the normality assumption for the distributions of diagnostic biomarkers. In this article, we propose a new method to correct AUC for measurement error and derive approximate confidence limits for the corrected AUC. The proposed method does not require the normality assumption. Both real data analyses and simulation studies show good performance of the proposed measurement error correction method.

  19. Scalable Nonlinear AUC Maximization Methods

    OpenAIRE

    Khalid, Majdi; Ray, Indrakshi; Chitsaz, Hamidreza

    2017-01-01

    The area under the ROC curve (AUC) is a measure of interest in various machine learning and data mining applications. It has been widely used to evaluate classification performance on heavily imbalanced data. The kernelized AUC maximization machines have established a superior generalization ability compared to linear AUC machines because of their capability in modeling the complex nonlinear structure underlying most real world-data. However, the high training complexity renders the kernelize...

  20. Analysis of spatial distribution of land cover maps accuracy

    Science.gov (United States)

    Khatami, R.; Mountrakis, G.; Stehman, S. V.

    2017-12-01

    Land cover maps have become one of the most important products of remote sensing science. However, classification errors will exist in any classified map and affect the reliability of subsequent map usage. Moreover, classification accuracy often varies over different regions of a classified map. These variations of accuracy will affect the reliability of subsequent analyses of different regions based on the classified maps. The traditional approach of map accuracy assessment based on an error matrix does not capture the spatial variation in classification accuracy. Here, per-pixel accuracy prediction methods are proposed based on interpolating accuracy values from a test sample to produce wall-to-wall accuracy maps. Different accuracy prediction methods were developed based on four factors: predictive domain (spatial versus spectral), interpolation function (constant, linear, Gaussian, and logistic), incorporation of class information (interpolating each class separately versus grouping them together), and sample size. Incorporation of spectral domain as explanatory feature spaces of classification accuracy interpolation was done for the first time in this research. Performance of the prediction methods was evaluated using 26 test blocks, with 10 km × 10 km dimensions, dispersed throughout the United States. The performance of the predictions was evaluated using the area under the curve (AUC) of the receiver operating characteristic. Relative to existing accuracy prediction methods, our proposed methods resulted in improvements of AUC of 0.15 or greater. Evaluation of the four factors comprising the accuracy prediction methods demonstrated that: i) interpolations should be done separately for each class instead of grouping all classes together; ii) if an all-classes approach is used, the spectral domain will result in substantially greater AUC than the spatial domain; iii) for the smaller sample size and per-class predictions, the spectral and spatial domain

  1. The fabrication process of ceramic grade UO2 powder via fluorid system AUC and the treatment on AUC precipitation filtrate

    International Nuclear Information System (INIS)

    Liu Jinhong; Xu Kui; Li Zhiwan; Yi Wei; Tang Yueming; Li Guangrong; Lei Maolin; Cui Chuanjiang

    2006-10-01

    It is described about the technology of fabricating AUC powder by Circum-fluence Precipitation Reactor with Gas (CPRG) from UF 6 hydrolyzed liquid, manufacturing nuclear pure ceramic grade UO 2 powder via fluorid system AUC process with fluidized bed method, recovering U(VI) with ion exchange resin, depositing fluorin in an outflow of effusion wastewater from the ion exchange using calces. The primary control parameters on the fabricating AUC powder is study, it is discussed to character difference of AUC powder between fluorid system and nitrate. Result show that the composing the manufacture AUC powder is invariable by CORG, and that the AUC quality is consistent, and that by decomposition and reduction of AUC and stabilization of UO 2 powder with fluidized bed, through optimum technological parameters, the excellent UO 2 powder is obtained on the quality. (authors)

  2. Determination of uranium content and its impurities in the AUC and UO2 powders

    International Nuclear Information System (INIS)

    Boybul; Arif Nugroho

    2012-01-01

    The analysis of uranium (U) content and its impurities in the ammonium uranyl carbonate (AUC) and uranium dioxide (UO 2 ) produced from research reactor fuel element production installation, PT. BATAN Teknologi have been carried out. Uranium content in the powders was analyzed by potentiometric titration methods and impurity contents was analyzed by atomic absorption spectrophotometer (AAS) and by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). The purpose of this study was to determine of impurity elements in the AUC and UO 2 powder resulting from the production process if it meets the required specifications. It is reported that U content in the AUC is 48.62 wt% and that in the UO 2 is 88.08 wt%. The precision and accuracy analysis of the U content is 0,235% and 0,151%. In case of impurities in the AUC powders, it is reported that the analytical results of Zn, Ni, Cd, Co, Mn, Mg, Fe, Cu and Cr at 10.15 ppm, 1.12 ppm, not detection, not detection, not detection, 0.30 ppm, 216.07 ppm, not detection, and 31.36 ppm, respectively, while that UO 2 are 11.31 ppm, 72.14 ppm, not detection, not detection, 6.25 ppm, 8.65 ppm, 298.24 ppm, 12.75 ppm and 32, 23 ppm. The U and impurity contents in both the AUC and UO 2 fulfill the specification of nuclear fuel for RSG-GAS research reactor. (author)

  3. Diagnostic accuracy of presepsin (sCD14-ST) as a biomarker of infection and sepsis in the emergency department.

    Science.gov (United States)

    de Guadiana Romualdo, Luis García; Torrella, Patricia Esteban; Acebes, Sergio Rebollo; Otón, María Dolores Albaladejo; Sánchez, Roberto Jiménez; Holgado, Ana Hernando; Santos, Enrique Jiménez; Freire, Alejandro Ortín

    2017-01-01

    Presepsin is a promising biomarker for the diagnosis and prognosis of sepsis. However, results reported about its value to diagnose sepsis in an emergency department (ED) are controversial, probably due to differences in the design of the studies. We have evaluated the diagnostic accuracy of presepsin for infection and sepsis, compared with procalcitonin (PCT) and C-reactive protein (CRP), in patients presenting to the emergency department (ED) with suspected infection. 223 patients with suspected infection were enrolled for the study. Blood samples were collected on admission for measurement of biomarkers. Definitive diagnosis was obtained afterwards by analysis of digital medical records. Receiver operating characteristic (ROC) curve analysis was conducted to determine the diagnostic accuracy. Infection was confirmed in 200 patients, including 130 with non-complicated infection and 70 with sepsis. Median CRP, PCT and presepsin levels were significantly higher in patients with infection and sepsis. PCT was the biomarker with the highest performance for infection (ROC AUC: 0.910); for sepsis, PCT (ROC AUC: 0.815) and presepsin (ROC AUC: 0.775) shown a similar performance. Although presepsin is a valuable biomarker for diagnosis of infection and sepsis, its diagnostic accuracy in our study does not improve that of PCT. Its introduction in clinical practice is not justified. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Highly Stable [C60AuC60]+/- Dumbbells.

    Science.gov (United States)

    Goulart, Marcelo; Kuhn, Martin; Martini, Paul; Chen, Lei; Hagelberg, Frank; Kaiser, Alexander; Scheier, Paul; Ellis, Andrew M

    2018-05-17

    Ionic complexes between gold and C 60 have been observed for the first time. Cations and anions of the type [Au(C 60 ) 2 ] +/- are shown to have particular stability. Calculations suggest that these ions adopt a C 60 -Au-C 60 sandwich-like (dumbbell) structure, which is reminiscent of [XAuX] +/- ions previously observed for much smaller ligands. The [Au(C 60 ) 2 ] +/- ions can be regarded as Au(I) complexes, regardless of whether the net charge is positive or negative, but in both cases, the charge transfer between the Au and C 60 is incomplete, most likely because of a covalent contribution to the Au-C 60 binding. The C 60 -Au-C 60 dumbbell structure represents a new architecture in fullerene chemistry that might be replicable in synthetic nanostructures.

  5. A modified Wald interval for the area under the ROC curve (AUC) in diagnostic case-control studies.

    Science.gov (United States)

    Kottas, Martina; Kuss, Oliver; Zapf, Antonia

    2014-02-19

    The area under the receiver operating characteristic (ROC) curve, referred to as the AUC, is an appropriate measure for describing the overall accuracy of a diagnostic test or a biomarker in early phase trials without having to choose a threshold. There are many approaches for estimating the confidence interval for the AUC. However, all are relatively complicated to implement. Furthermore, many approaches perform poorly for large AUC values or small sample sizes. The AUC is actually a probability. So we propose a modified Wald interval for a single proportion, which can be calculated on a pocket calculator. We performed a simulation study to compare this modified Wald interval (without and with continuity correction) with other intervals regarding coverage probability and statistical power. The main result is that the proposed modified Wald intervals maintain and exploit the type I error much better than the intervals of Agresti-Coull, Wilson, and Clopper-Pearson. The interval suggested by Bamber, the Mann-Whitney interval without transformation and also the interval of the binormal AUC are very liberal. For small sample sizes the Wald interval with continuity has a comparable coverage probability as the LT interval and higher power. For large sample sizes the results of the LT interval and of the Wald interval without continuity correction are comparable. If individual patient data is not available, but only the estimated AUC and the total sample size, the modified Wald intervals can be recommended as confidence intervals for the AUC. For small sample sizes the continuity correction should be used.

  6. Application of Hill's equation for estimating area under the concentration-time curve (AUC) and use of time to AUC 90% for expressing kinetics of drug disposition.

    Science.gov (United States)

    Cheng, Hsien C

    2009-01-01

    Half life and its derived pharmacokinetic parameters are calculated on an assumption that the terminal phase of drug disposition follows a constant rate of disposition. In reality, this assumption may not necessarily be the case. A new method is needed for analyzing PK parameters if the disposition does not follow a first order PK kinetic. Cumulative area under the concentration-time curve (AUC) is plotted against time to yield a hyperbolic (or sigmoidal) AUC-time relationship curve which is then analyzed by Hill's equation to yield AUC(inf), time to achieving AUC50% (T(AUC50%)) or AUC90% (T(AUC90%)), and the Hill's slope. From these parameters, an AUC-time relationship curve can be reconstructed. Projected plasma concentration can be calculated for any time point. Time at which cumulative AUC reaches 90% (T(AUC90%)) can be used as an indicator for expressing how fast a drug is cleared. Clearance is calculated in a traditional manner (i.v. dose/AUC(inf)), and the volume of distribution is proposed to be calculated at T(AUC50%) (0.5 i.v. dose/plasma concentration at T(AUC50%)). This method of estimating AUC is applicable for both i.v. and oral data. It is concluded that the Hill's equation can be used as an alternative method for estimating AUC and analysis of PK parameters if the disposition does not follow a first order kinetic. T(AUC90%) is proposed to be used as an indicator for expressing how fast a drug is cleared from the system.

  7. Combining large number of weak biomarkers based on AUC.

    Science.gov (United States)

    Yan, Li; Tian, Lili; Liu, Song

    2015-12-20

    Combining multiple biomarkers to improve diagnosis and/or prognosis accuracy is a common practice in clinical medicine. Both parametric and non-parametric methods have been developed for finding the optimal linear combination of biomarkers to maximize the area under the receiver operating characteristic curve (AUC), primarily focusing on the setting with a small number of well-defined biomarkers. This problem becomes more challenging when the number of observations is not order of magnitude greater than the number of variables, especially when the involved biomarkers are relatively weak. Such settings are not uncommon in certain applied fields. The first aim of this paper is to empirically evaluate the performance of existing linear combination methods under such settings. The second aim is to propose a new combination method, namely, the pairwise approach, to maximize AUC. Our simulation studies demonstrated that the performance of several existing methods can become unsatisfactory as the number of markers becomes large, while the newly proposed pairwise method performs reasonably well. Furthermore, we apply all the combination methods to real datasets used for the development and validation of MammaPrint. The implication of our study for the design of optimal linear combination methods is discussed. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Microstructure study of AUC and UO2

    International Nuclear Information System (INIS)

    Pan Ying; Gao Dihua; Lu Huaichang

    1992-01-01

    The microstructures of AUC, UO 2 powder and pellets were investigated with metallo-scope, SEM, TEM, XRD, and image analyzer. The influence of the reduction conditions of AUC on the microstructures of UO 2 powder and pellet were studied

  9. Direct AUC optimization of regulatory motifs.

    Science.gov (United States)

    Zhu, Lin; Zhang, Hong-Bo; Huang, De-Shuang

    2017-07-15

    The discovery of transcription factor binding site (TFBS) motifs is essential for untangling the complex mechanism of genetic variation under different developmental and environmental conditions. Among the huge amount of computational approaches for de novo identification of TFBS motifs, discriminative motif learning (DML) methods have been proven to be promising for harnessing the discovery power of accumulated huge amount of high-throughput binding data. However, they have to sacrifice accuracy for speed and could fail to fully utilize the information of the input sequences. We propose a novel algorithm called CDAUC for optimizing DML-learned motifs based on the area under the receiver-operating characteristic curve (AUC) criterion, which has been widely used in the literature to evaluate the significance of extracted motifs. We show that when the considered AUC loss function is optimized in a coordinate-wise manner, the cost function of each resultant sub-problem is a piece-wise constant function, whose optimal value can be found exactly and efficiently. Further, a key step of each iteration of CDAUC can be efficiently solved as a computational geometry problem. Experimental results on real world high-throughput datasets illustrate that CDAUC outperforms competing methods for refining DML motifs, while being one order of magnitude faster. Meanwhile, preliminary results also show that CDAUC may also be useful for improving the interpretability of convolutional kernels generated by the emerging deep learning approaches for predicting TF sequences specificities. CDAUC is available at: https://drive.google.com/drive/folders/0BxOW5MtIZbJjNFpCeHlBVWJHeW8 . dshuang@tongji.edu.cn. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  10. AUK: a simple alternative to the AUC

    NARCIS (Netherlands)

    Kaymak, U.; Ben-David, A.; Potharst, R.

    2010-01-01

    The area under Receiver Operating Characteristic (ROC) curve, also known as the AUC-index, is commonly used for ranking the performance of data mining models. The AUC has many merits, such as objectivity and ease of interpretation. However, since it is class indifferent, its usefulness while dealing

  11. AUK: a simple alternative to the AUC

    NARCIS (Netherlands)

    U. Kaymak (Uzay); A. Ben-David (Arie); R. Potharst (Rob)

    2010-01-01

    textabstractThe area under Receiver Operating Characteristic (ROC) curve, also known as the AUC-index, is commonly used for ranking the performance of data mining models. The AUC has many merits, such as objectivity and ease of interpretation. However, since it is class indifferent, its usefulness

  12. The impact of composite AUC estimates on the prediction of systemic exposure in toxicology experiments.

    Science.gov (United States)

    Sahota, Tarjinder; Danhof, Meindert; Della Pasqua, Oscar

    2015-06-01

    Current toxicity protocols relate measures of systemic exposure (i.e. AUC, Cmax) as obtained by non-compartmental analysis to observed toxicity. A complicating factor in this practice is the potential bias in the estimates defining safe drug exposure. Moreover, it prevents the assessment of variability. The objective of the current investigation was therefore (a) to demonstrate the feasibility of applying nonlinear mixed effects modelling for the evaluation of toxicokinetics and (b) to assess the bias and accuracy in summary measures of systemic exposure for each method. Here, simulation scenarios were evaluated, which mimic toxicology protocols in rodents. To ensure differences in pharmacokinetic properties are accounted for, hypothetical drugs with varying disposition properties were considered. Data analysis was performed using non-compartmental methods and nonlinear mixed effects modelling. Exposure levels were expressed as area under the concentration versus time curve (AUC), peak concentrations (Cmax) and time above a predefined threshold (TAT). Results were then compared with the reference values to assess the bias and precision of parameter estimates. Higher accuracy and precision were observed for model-based estimates (i.e. AUC, Cmax and TAT), irrespective of group or treatment duration, as compared with non-compartmental analysis. Despite the focus of guidelines on establishing safety thresholds for the evaluation of new molecules in humans, current methods neglect uncertainty, lack of precision and bias in parameter estimates. The use of nonlinear mixed effects modelling for the analysis of toxicokinetics provides insight into variability and should be considered for predicting safe exposure in humans.

  13. Diagnostic terminology for urinary cytology reports including the new subcategories 'atypical urothelial cells of undetermined significance' (AUC-US) and 'cannot exclude high grade' (AUC-H).

    Science.gov (United States)

    Piaton, E; Decaussin-Petrucci, M; Mege-Lechevallier, F; Advenier, A-S; Devonec, M; Ruffion, A

    2014-02-01

    We studied whether atypical, non-superficial urothelial cells (AUC) could be separated into new subcategories including AUC 'of undetermined significance' (AUC-US) and 'cannot exclude high grade'' (AUC-H) in order to help to standardize urine cytopathology reports, as it is widely accepted in the Bethesda system for gynaecological cytopathology. We investigated whether AUC-US and AUC-H, defined by distinctive cytological criteria, might be separated with statistical significance according to actual diagnosis and follow-up data. A series of 534 cyto-histological comparisons taken in 139 patients, including 221 AUC at various steps of their clinical history was studied. There were 513 (96.1%) postcystoscopy and 469 (87.8%) ThinPrep® liquid-based specimens (95.9% and 89.1% of AUC cases, respectively). Patients viewed between 1999 and 2011 had histological control in a 0- to 6-months delay and were followed-up during an additional 5.9 ± 9.2 (0- to 56-) months period. The 221 AUC represented 0.8-2% of the specimens viewed during the study period. Among AUC-H cases, 70 out of 185 (37.8%) matched with high-grade lesions, compared with 3 of 38 (8.3%) of AUC-US cases (P = 0.0003). Conservatively treated patients with AUC-H more frequently developed high-grade lesions than those with AUC-US (54.1% versus 16.7%, P = 0.0007) with a 17.6-months mean delay. Nuclear hyperchromasia, a nuclear to cytoplasm (N/C) ratio > 0.7 and the combination of both were the more informative diagnostic criteria, all with P < 0.01. We conclude that the new subcategories could help to standardize urine cytopathology reports and contribute to the patient's management, provided it is validated by multicentric studies. © 2013 John Wiley & Sons Ltd.

  14. 78 FR 47427 - AUC, LLC Reno Creek, In Situ

    Science.gov (United States)

    2013-08-05

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 040-09092; NRC-2013-0164] AUC, LLC Reno Creek, In Situ... October 3, 2012, AUC submitted a license application to the U.S. Nuclear Regulatory Commission (NRC... provided the first time that a document is referenced. The AUC License Application request and additional...

  15. Decomposition and reduction of AUC in hydrogen

    International Nuclear Information System (INIS)

    Ge Qingren; Kang Shifang; Zhou Meng

    1987-01-01

    AUC (Ammonium Uranyl Carbonate) conversion processes have been adopted extensively in nuclear fuel cycle. The kinetics investigation of these processes, however, has not yet been reported in detail at the published literatures. In the present work, the decomposition kinetics of AUC in hydrogen has been determined by non-isothermal method. DSC curves are solved with computer by Ge Qingren method. The results show that the kinetics obeys Avrami-Erofeev equation within 90% conversion. The apparent activation energy and preexponent are found to be 113.0 kJ/mol and 7.11 x 10 11 s -1 respectively. The reduction kinetics of AUC decomposition product in hydrogen at the range of 450 - 600 deg C has been determined by isothermal thermogravimetric method. The results show that good linear relationship can be obtained from the plot of conversion vs time, and that the apparent activation energy is found to be 113.9 kJ/mol. The effects of particle size and partial pressure of hydrogen are examined in reduction of AUC decomposition product. The reduction mechanism and the structure of particle are discussed according to the kinetics behaviour and SEM (scanning electron microscope) photograph

  16. Accuracy and reading time for six strategies using digital breast tomosynthesis in women with mammographically negative dense breasts.

    Science.gov (United States)

    Tagliafico, Alberto Stefano; Calabrese, Massimo; Bignotti, Bianca; Signori, Alessio; Fisci, Erica; Rossi, Federica; Valdora, Francesca; Houssami, Nehmat

    2017-12-01

    To compare six strategies using digital breast tomosynthesis in women with mammographically negative dense breasts. This is a substudy of the 'ASTOUND' trial. 163 women who underwent tomosynthesis with synthetically reconstructed projection images (S-2D) inclusive of 13 (7.9%) cases diagnosed with breast cancer at histopathology after surgery were evaluated. Accuracy measures and screen-reading time of six reading strategies were assessed: (A) Single reading of S-2D alone, (B) single reading of tomosynthesis alone, (C) single reading of joint interpretation of tomosynthesis + S-2D, (D) double-reading of S-2D alone, (E) double reading of tomosynthesis alone, (F) double reading of joint interpretation of tomosynthesis + S-2D. The median age of the patients was 53 years (range, 36-88 years). The highest global accuracy was obtained with double reading of tomosynthesis + S2D (F) with an AUC of 0.979 (ptomosynthesis+ S2D had the best accuracy of six screen-reading strategies although it had the longest reading time. • Tomosynthesis acquisitions are progressively implemented with reconstructed synthesized 2D images • Double reading using S-2D plus tomosynthesis had the highest global accuracy (ptomosynthesis increased reading time.

  17. Predictive value of modeled AUC(AFP-hCG), a dynamic kinetic parameter characterizing serum tumor marker decline in patients with nonseminomatous germ cell tumor.

    Science.gov (United States)

    You, Benoit; Fronton, Ludivine; Boyle, Helen; Droz, Jean-Pierre; Girard, Pascal; Tranchand, Brigitte; Ribba, Benjamin; Tod, Michel; Chabaud, Sylvie; Coquelin, Henri; Fléchon, Aude

    2010-08-01

    The early decline profile of alpha-fetoprotein (AFP) and human chorionic gonadotropin (hCG) in patients with nonseminomatous germ cell tumors (NSGCT) treated with chemotherapy may be related to the risk of relapse. We assessed the predictive values of areas under the curve of hCG (AUC(hCG)) and AFP (AUC(AFP)) of modeled concentration-time equations on progression-free survival (PFS). Single-center retrospective analysis of hCG and AFP time-points from 65 patients with IGCCCG intermediate-poor risk NSGCT treated with 4 cycles of bleomycin-etoposide-cisplatin (BEP). To determine AUC(hCG) and AUC(AFP) for D0-D42, AUCs for D0-D7 were calculated using the trapezoid rule and AUCs for D7-D42 were calculated using the mathematic integrals of equations modeled with NONMEM. Combining AUC(AFP) and AUC(hCG) enabled us to define 2 predictive groups: namely, patients with favorable and unfavorable AUC(AFP-hCG). Survival analyses and ROC curves assessed the predictive values of AUC(AFP-hCG) groups regarding progression-free survival (PFS) and compared them with those of half-life (HL) and time-to-normalization (TTN). Mono-exponential models best fit the patterns of marker decreases. Patients with a favorable AUC(AFP-hCG) had a significantly better PFS (100% vs 71.5%, P = .014). ROC curves confirmed the encouraging predictive accuracy of AUC(AFP-hCG) against HL or TTN regarding progression risk (ROC AUCs = 79.6 vs 71.9 and 70.2 respectively). Because of the large number of patients with missing data, multivariate analysis could not be performed. AUC(AFP-hCG) is a dynamic parameter characterizing tumor marker decline in patients with NSGCT during BEP treatment. Its value as a promising predictive factor should be validated. Copyright 2010 Elsevier Inc. All rights reserved.

  18. The AUK : a simple alternative to the AUC

    NARCIS (Netherlands)

    Kaymak, U.; Ben-David, A.; Potharst, R.

    2012-01-01

    The area under the receiver operating characteristic (ROC) curve, also known as the AUC-index, is commonly used for ranking the performance of data mining models. The AUC has various merits, such as ease of interpretation. However, since it is class indifferent, its usefulness while dealing with

  19. A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis

    International Nuclear Information System (INIS)

    Michell, M.J.; Iqbal, A.; Wasan, R.K.; Evans, D.R.; Peacock, C.; Lawinski, C.P.; Douiri, A.; Wilson, R.; Whelehan, P.

    2012-01-01

    Aim: To measure the change in diagnostic accuracy of conventional film-screen mammography and full-field digital mammography (FFDM) with the addition of digital breast tomosynthesis (DBT) in women recalled for assessment following routine screening. Materials and methods: Ethics approval for the study was granted. Women recalled for assessment following routine screening with screen-film mammography were invited to participate. Participants underwent bilateral, two-view FFDM and two-view DBT. Readers scored each lesion separately for probability of malignancy on screen-film mammography, FFDM, and then DBT. The scores were compared with the presence or absence of malignancy based on the final histopathology outcome. Results: Seven hundred and thirty-eight women participated (93.2% recruitment rate). Following assessment 204 (26.8%) were diagnosed as malignant (147 invasive and 57 in-situ tumours), 286 (37.68%) as benign, and 269 (35.4%) as normal. The diagnostic accuracy was evaluated by using receiving operating characteristic (ROC) and measurement of area under the curve (AUC). The AUC values demonstrated a significant (p = 0.0001) improvement in the diagnostic accuracy with the addition of DBT combined with FFDM and film-screen mammography (AUC = 0.9671) when compared to FFDM plus film-screen mammography (AUC = 0.8949) and film-screen mammography alone (AUC = 0.7882). The effect was significantly greater for soft-tissue lesions [AUC was 0.9905 with the addition of DBT and AUC was 0.9201 for FFDM with film-screen mammography combined (p = 0.0001)] compared to microcalcification [with the addition of DBT (AUC = 0.7920) and for FFDM with film-screen mammography combined (AUC = 0.7843; p = 0.3182)]. Conclusion: The addition of DBT increases the accuracy of mammography compared to FFDM and film-screen mammography combined and film-screen mammography alone in the assessment of screen-detected soft-tissue mammographic abnormalities.

  20. Crystallization characteristics of ammonium uranyl carbonate (AUC) in ammonium carbonate solutions

    International Nuclear Information System (INIS)

    Kim, T.J.; Jeong, K.C.; Park, J.H.; Chang, I.S.; Choi, C.S.

    1994-01-01

    Ammonium carbonate solutions with an excessive amount of NH 3 were produced in a commercial AUC (ammonium uranyl carbonate) conversion plant. In this study the AUC crystals, precipitated with uranyl nitrate and ammonium carbonate solutions prepared in the laboratory, were characterized to determine the feasibility of recycling ammonium carbonate solution. The AUC crystals were easily agglomerated with the increasing concentration of CO 3 2- and mole ratio of NH 4 + /CO 3 2- in ammonium carbonate solution. Effects of a mixing system for the solution in the AUC crystallizer and the feed location of the solution onthe agglomeration of AUC crystals were also studied along with the effects of agglomerated AUC powders on UO 2 powders. Finally, the feasibility of manufacturing UO 2 fuel with a sintered pellet density of 10.52 g/cm 3 , using the AUC powders generated in this experiment, was demonstrated. (orig.)

  1. Diagnostic accuracy of routine blood examinations and CSF lactate level for post-neurosurgical bacterial meningitis.

    Science.gov (United States)

    Zhang, Yang; Xiao, Xiong; Zhang, Junting; Gao, Zhixian; Ji, Nan; Zhang, Liwei

    2017-06-01

    To evaluate the diagnostic accuracy of routine blood examinations and Cerebrospinal Fluid (CSF) lactate level for Post-neurosurgical Bacterial Meningitis (PBM) at a large sample-size of post-neurosurgical patients. The diagnostic accuracies of routine blood examinations and CSF lactate level to distinguish between PAM and PBM were evaluated with the values of the Area Under the Curve of the Receiver Operating Characteristic (AUC -ROC ) by retrospectively analyzing the datasets of post-neurosurgical patients in the clinical information databases. The diagnostic accuracy of routine blood examinations was relatively low (AUC -ROC CSF lactate level achieved rather high diagnostic accuracy (AUC -ROC =0.891; CI 95%, 0.852-0.922). The variables of patient age, operation duration, surgical diagnosis and postoperative days (the interval days between the neurosurgery and examinations) were shown to affect the diagnostic accuracy of these examinations. The variables were integrated with routine blood examinations and CSF lactate level by Fisher discriminant analysis to improve their diagnostic accuracy. As a result, the diagnostic accuracy of blood examinations and CSF lactate level was significantly improved with an AUC -ROC value=0.760 (CI 95%, 0.737-0.782) and 0.921 (CI 95%, 0.887-0.948) respectively. The PBM diagnostic accuracy of routine blood examinations was relatively low, whereas the accuracy of CSF lactate level was high. Some variables that are involved in the incidence of PBM can also affect the diagnostic accuracy for PBM. Taking into account the effects of these variables significantly improves the diagnostic accuracies of routine blood examinations and CSF lactate level. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Precise determination of protein extinction coefficients under native and denaturing conditions using SV-AUC.

    Science.gov (United States)

    Hoffmann, Andreas; Grassl, Kerstin; Gommert, Janine; Schlesak, Christian; Bepperling, Alexander

    2018-04-17

    The accurate determination of protein concentration is an important though non-trivial task during the development of a biopharmaceutical. The fundamental prerequisite for this is the availability of an accurate extinction coefficient. Common approaches for the determination of an extinction coefficient for a given protein are either based on the theoretical prediction utilizing the amino acid sequence or the photometric determination combined with a measurement of absolute protein concentration. Here, we report on an improved SV-AUC based method utilizing an analytical ultracentrifuge equipped with absorbance and Rayleigh interference optics. Global fitting of datasets helped to overcome some of the obstacles encountered with the traditional method employing synthetic boundary cells. Careful calculation of dn/dc values taking glycosylation and solvent composition into account allowed the determination of the extinction coefficients of monoclonal antibodies and an Fc-fusion protein under native as well as under denaturing conditions. An intra-assay precision of 0.9% and an accuracy of 1.8% compared to the theoretical value was achieved for monoclonal antibodies. Due to the large number of data points of a single dataset, no meaningful difference between the ProteomeLab XL-I and the new Optima AUC platform could be observed. Thus, the AUC-based approach offers a precise, convenient and versatile alternative to conventional methods like total amino acid analysis (AAA).

  3. Probing the electronic structure and Au–C chemical bonding in AuC2− and AuC2 using high-resolution photoelectron spectroscopy

    International Nuclear Information System (INIS)

    León, Iker; Yang, Zheng; Wang, Lai-Sheng

    2014-01-01

    We report photoelectron spectroscopy (PES) and high-resolution PE imaging of AuC 2 − at a wide range of photon energies. The ground state of AuC 2 − is found to be linear (C ∞v , 1 Σ + ) with a …8π 4 4δ 4 17σ 2 9π 4 18σ 2 valence configuration. Detachments from all the five valence orbitals of the ground state of AuC 2 − are observed at 193 nm. High-resolution PE images are obtained in the energy range from 830 to 330 nm, revealing complicated vibronic structures from electron detachment of the 18σ, 9π, and 17σ orbitals. Detachment from the 18σ orbital results in the 2 Σ + ground state of neutral AuC 2 , which, however, is bent due to strong vibronic coupling with the nearby 2 Π state from detachment of a 9π electron. The 2 Σ + – 2 Π vibronic and spin-orbit coupling results in complicated vibronic structures for the 2 Σ + and 2 Π 3/2 states with extensive bending excitations. The electron affinity of AuC 2 is measured accurately to be 3.2192(7) eV with a ground state bending frequency of 195(6) cm −1 . The first excited state ( 2 A′) of AuC 2 , corresponding to the 2 Π 3/2 state at the linear geometry, is only 0.0021 eV above the ground state ( 2 A′) and has a bending frequency of 207(6) cm −1 . The 2 Π 1/2 state, 0.2291 eV above the ground state, is linear with little geometry change relative to the anion ground state. The detachment of the 17σ orbital also results in complicated vibronic structures, suggesting again a bent state due to possible vibronic coupling with the lower 2 Π state. The spectrum at 193 nm shows the presence of a minor species with less than 2% intensity relative to the ground state of AuC 2 − . High-resolution data of the minor species reveal several vibrational progressions in the Au–C stretching mode, which are assigned to be from the metastable 3 Π 2,1,0 spin-orbit excited states of AuC 2 − to the 2 Π 3/2,1/2 spin-orbit states of neutral AuC 2 . The spin-orbit splittings of the 3 Π and 2

  4. Purification of ADU and high-molybdenum AUC by recrystallization

    International Nuclear Information System (INIS)

    Tan Huanchang; Wen Jinfeng

    1995-01-01

    The ADU was converted to AUC by preparing pulp with (NH 4 ) 2 CO 3 concentrated solution, and then the prepared AUC (high-molybdenum AUC) crystals were dissolved with hot soft water for dissolution, and after filtration or clarification and scrubbing of the residue, and the clarified solution was digested and the obtained pulp was thickened and the thickened pulp was converted and recrystallized by adding (NH 4 ) 2 CO 3 concentrated solution. The crystals were washed and filtrated, and then the high-purity AUC crystals were prepared. The laboratory and pilot-plant scale experiments showed that the presented purification process was feasible with the solvent extraction step eliminated, so the chemicals consumption would be considerably decreased and the environmental pollution would be lowered. It is easy to realize the process in practice

  5. [Atypical urothelial cells (AUC): A Bethesda-derived wording applicable to urinary cytopathology].

    Science.gov (United States)

    Piaton, Eric; Advenier, Anne-Sophie; Benaïm, Gilles; Petrucci, Myriam Decaussin; Lechevallier, Florence Mege; Ruffion, Alain

    2011-02-01

    To investigate (1) whether sparse nuclear atypias involving deep urothelial cells have a diagnostic or prognostic value in urinary cytology, and (2) whether the terms atypical urothelial cells "of undetermined significance" (AUC-US) or "cannot exclude high grade" (AUC-H) might be used to standardize urinary cytology reports. Atypical urothelial cells (AUC) were defined as deep cells with nuclear abnormalities (increased N/C ratio, eccentric nucleus, hyperchromatism and/or irregular shape) in small number not allowing their categorization as malignant, high grade. We studied 435 urinary samples from 126 patients with AUC at any step of their clinical history, followed up over a 10-year period (1999-2009). Every case was compared with histopathology within 6 months and to long term follow-up including cystoscopy and histopathology combined. A total of 183 AUC was recorded. AUC were associated with negative, benign or low grade histological results in 36 of 106 cases (33.9 %) within 6 months, but a high grade was simultaneously documented in 70 cases (66 %). AUC preceded high-grade lesions in 66 cases (36.1 % of all AUC) in a mean interval of 10.5±12.0 months. Overall, AUC were associated with or predictive of high-grade lesions in 135 cases (73.8 %). AUC have a diagnostic and prognostic value. Applying the terms AUC-US and AUC-H to urinary cytopathology reports would allow, as for the Bethesda system for cervical or vaginal cytologic diagnoses, better appreciation of the risk of progression to high grade tumours in cases with atypias. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  6. Efficient AUC optimization for classification

    NARCIS (Netherlands)

    Calders, T.; Jaroszewicz, S.; Kok, J.N.; Koronacki, J.; Lopez de Mantaras, R.; Matwin, S.; Mladenic, D.; Skowron, A.

    2007-01-01

    In this paper we show an efficient method for inducing classifiers that directly optimize the area under the ROC curve. Recently, AUC gained importance in the classification community as a mean to compare the performance of classifiers. Because most classification methods do not optimize this

  7. Study On Precipitation Of UO2 Ex-AUC Powder. Part I: Precipitation Of AUC By (NH4)2CO3 From Uranyl Fluoride Solution

    International Nuclear Information System (INIS)

    Nguyen Trong Hung; Le Ba Thuan; Do Van Khoai; Nguyen Thanh Thuy; Nguyen Van Tung

    2011-01-01

    In this paper, Ammonium Uranyl Carbonate (AUC) powders were prepared by precipitation method in solution. UO 2 F 2 /HF, ammonium carbonate (AC), and ammonium hydroxide solution were used as precursors for precipitation. The influence of C/U ratio (mol/mol), AC concentration (g/L), reaction temperature ( o C), on characteristics of AUC powders was also investigated. Then, the synthesized AUC powders were analyzed (to define) phase composition (X-ray), fluorine content, morphology (by SEM), and specific surface area (BET). (author)

  8. Limited Sampling Strategy for the Prediction of Area Under the Curve (AUC) of Statins: Reliability of a Single Time Point for AUC Prediction for Pravastatin and Simvastatin.

    Science.gov (United States)

    Srinivas, N R

    2016-02-01

    Statins are widely prescribed medicines and are also available in fixed dose combinations with other drugs to treat several chronic ailments. Given the safety issues associated with statins it may be important to assess feasibility of a single time concentration strategy for prediction of exposure (area under the curve; AUC). The peak concentration (Cmax) was used to establish relationship with AUC separately for pravastatin and simvastatin using published pharmacokinetic data. The regression equations generated for statins were used to predict the AUC values from various literature references. The fold difference of the observed divided by predicted values along with correlation coefficient (r) were used to judge the feasibility of the single time point approach. Both pravastatin and simvastatin showed excellent correlation of Cmax vs. AUC values with r value ≥ 0.9638 (pAUC predictions and >81% of the predicted values were in a narrower range of >0.75-fold but AUC values showed excellent correlation for pravastatin (r=0.9708, n=115; pAUC predictions. On the basis of the present work, it is feasible to develop a single concentration time point strategy that coincides with Cmax occurrence for both pravastatin and simvastatin from a therapeutic drug monitoring perspective. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Preparation and characterization of antibacterial Au/C core-shell composite

    Energy Technology Data Exchange (ETDEWEB)

    Gao Yanhong [Department of Chemistry and Institute of Nanochemistry, Jinan University, 601 Huangpudadaoxi Road, Guangzhou 510632, Guangdong (China); Centers for Disease Control and Prevention of Guangdong Province, Guangzhou 510300, Guangdong (China); Zhang Nianchun [Department of Chemistry and Institute of Nanochemistry, Jinan University, 601 Huangpudadaoxi Road, Guangzhou 510632, Guangdong (China); Zhong Yuwen [Centers for Disease Control and Prevention of Guangdong Province, Guangzhou 510300, Guangdong (China); Cai Huaihong [Department of Chemistry and Institute of Nanochemistry, Jinan University, 601 Huangpudadaoxi Road, Guangzhou 510632, Guangdong (China); Liu Yingliang, E-mail: tliuyl@jnu.edu.cn [Department of Chemistry and Institute of Nanochemistry, Jinan University, 601 Huangpudadaoxi Road, Guangzhou 510632, Guangdong (China)

    2010-09-01

    An environment-friendly oxidation-reduction method was used to prepare Au/C core-shell composite using carbon as core and gold as shell. The chemical structures and morphologies of Au/C core-shell composite and carbon sphere were characterized by X-ray diffraction, transmission electron microscope, energy dispersion X-ray spectrometry (EDS) and X-ray photoelectron spectroscopy (XPS). The antibacterial properties of the Au/C core-shell composite against Escherichia coli (E. coli), Staphylococcus aureus (S. aureus) and Candida albicans (C. albicans) were examined by the disk diffusion assay and minimal inhibition concentration (MIC) methods. In addition, antibacterial ability of Au/C core-shell composite was observed by atomic force microscope. Results demonstrated that gold homogeneously supported on the surface of carbon spheres without aggregation and showed efficient antibacterial abilities.

  10. Novel HPTLC and UV-AUC analyses: For simple, economical, and rapid determination of Zileuton racemate

    Directory of Open Access Journals (Sweden)

    Saurabh B. Ganorkar

    2017-03-01

    Full Text Available Novel, simple, rapid and reliable High-Performance Thin-Layer Chromatographic (HPTLC and UV-spectroscopic area under curve (UV-AUC methods were developed and validated for the analysis of zileuton racemate in bulk and in in-house tablet formulation. HPTLC quantitation of zileuton was done by UV detection at 260 nm and analysis was performed on (20 × 10 cm aluminium sheets precoated with silica gel 60-F254 (E. Merck as stationary phase and toluene–methanol–glacial acetic acid (3.5:1.5:0.1 v/v as mobile phase. Quantitation by HPTLC method was performed over the concentration range of 200–1200 ng/band. The HPTLC method resulted into a compact and well resolved band for zileuton at retention factor (Rf of 0.51 ± 0.02. Linear regression analysis data for calibration of HPTLC method represented a good linear relationship with regression coefficient; r2 = 0.997. UV-AUC method was developed using sodium lauryl sulphate (0.05 M as a hydrotropic agent to enhance water solubility and area was determined at a wavelength range in between 248.40 and 271.0 nm. Correlation coefficient for UV-AUC analysis was found to be r2 = 0.999. The developed UV-AUC method depicted a fine linear relationship for zileuton racemate in a concentration range of 2–12 μg/mL. Both the developed methods were validated for precision, robustness, ruggedness, accuracy, sensitivity as per guidelines laid by the International Conference on Harmonisation (ICH. Statistical analysis proved that the developed methods were precise, robust, sensitive and accurate and can be used effectively for the analysis of zileuton in bulk and pharmaceutical formulations.

  11. Next generation dilatometer for highest accuracy thermal expansion measurement of ZERODUR®

    Science.gov (United States)

    Jedamzik, Ralf; Engel, Axel; Kunisch, Clemens; Westenberger, Gerhard; Fischer, Peter; Westerhoff, Thomas

    2015-09-01

    In the recent years, the ever tighter tolerance for the Coefficient of thermal expansion (CTE) of IC Lithography component materials is requesting significant progress in the metrology accuracy to determine this property as requested. ZERODUR® is known for its extremely low CTE between 0°C to 50°C. The current measurement of the thermal expansion coefficient is done using push rod dilatometer measurement systems developed at SCHOTT. In recent years measurements have been published showing the excellent CTE homogeneity of ZERODUR® in the one-digit ppb/K range using these systems. The verifiable homogeneity was limited by the CTE(0°C, 50°C) measurement repeatability in the range of ± 1.2 ppb/K of the current improved push rod dilatometer setup using an optical interferometer as detector instead of an inductive coil. With ZERODUR® TAILORED, SCHOTT introduced a low thermal expansion material grade that can be adapted to individual customer application temperature profiles. The basis for this product is a model that has been developed in 2010 for better understanding of the thermal expansion behavior under given temperature versus time conditions. The CTE behavior predicted by the model has proven to be in very good alignment with the data determined in the thermal expansions measurements. The measurements to determine the data feeding the model require a dilatometer setup with excellent stability and accuracy for long measurement times of several days. In the past few years SCHOTT spent a lot of effort to drive a dilatometer measurement technology based on the push rod setup to its limit, to fulfill the continuously demand for higher CTE accuracy and deeper material knowledge of ZERODUR®. This paper reports on the status of the dilatometer technology development at SCHOTT.

  12. Use of partial AUC to demonstrate bioequivalence of Zolpidem Tartrate Extended Release formulations.

    Science.gov (United States)

    Lionberger, Robert A; Raw, Andre S; Kim, Stephanie H; Zhang, Xinyuan; Yu, Lawrence X

    2012-04-01

    FDA's bioequivalence recommendation for Zolpidem Tartrate Extended Release Tablets is the first to use partial AUC (pAUC) metrics for determining bioequivalence of modified-release dosage forms. Modeling and simulation studies were performed to aid in understanding the need for pAUC measures and also the proper pAUC truncation times. Deconvolution techniques, In Vitro/In Vivo Correlations, and the CAT (Compartmental Absorption and Transit) model were used to predict the PK profiles for zolpidem. Models were validated using in-house data submitted to the FDA. Using dissolution profiles expressed by the Weibull model as input for the CAT model, dissolution spaces were derived for simulated test formulations. The AUC(0-1.5) parameter was indicative of IR characteristics of early exposure and effectively distinguished among formulations that produced different pharmacodynamic effects. The AUC(1.5-t) parameter ensured equivalence with respect to the sustained release phase of Ambien CR. The variability of AUC(0-1.5) is higher than other PK parameters, but is reasonable for use in an equivalence test. In addition to the traditional PK parameters of AUCinf and Cmax, AUC(0-1.5) and AUC(1.5-t) are recommended to provide bioequivalence measures with respect to label indications for Ambien CR: onset of sleep and sleep maintenance.

  13. The production of sinterable UO2 from AUC

    International Nuclear Information System (INIS)

    Chang, I.S.; Do, J.B.; Choi, Y.D.; Park, M.H.; Yun, H.H.; Kim, E.H.; Kim, Y.W.

    1982-01-01

    Fluidization, feeding and discharging, and mixing of fine particles (-up to 40μ in diameter) in fluidized bed reactor has been examined. The degree of conversion has been estimated using the kinetic data differential scanning colorimetry(DSC) and thermogravimetic analysis (TGA) of ammonium uranyl carbonate (AUC) and residence time distribution data. Satisfactory operation is obtained with a sintered ceramic distributor and filters. The reactor equilvalent to approximately 1.1-1.3 stages. Thermal analysis of AUC in hydrogen atmosphere shows that the decomposition of AUC to UO 3 at 200degC is followed by reduction of UO 3 to UO 2 in two steps in the range between 400degC and 500degC and the complete conversion to UO 2 takes two minutes at 550degC. The overall conversion of above 99.5% in the fluidized bed reactor is estimated with 40 minutes of a mean particle residence time at 600degC. (Author)

  14. Clinical usefulness of limited sampling strategies for estimating AUC of proton pump inhibitors.

    Science.gov (United States)

    Niioka, Takenori

    2011-03-01

    Cytochrome P450 (CYP) 2C19 (CYP2C19) genotype is regarded as a useful tool to predict area under the blood concentration-time curve (AUC) of proton pump inhibitors (PPIs). In our results, however, CYP2C19 genotypes had no influence on AUC of all PPIs during fluvoxamine treatment. These findings suggest that CYP2C19 genotyping is not always a good indicator for estimating AUC of PPIs. Limited sampling strategies (LSS) were developed to estimate AUC simply and accurately. It is important to minimize the number of blood samples because of patient's acceptance. This article reviewed the usefulness of LSS for estimating AUC of three PPIs (omeprazole: OPZ, lansoprazole: LPZ and rabeprazole: RPZ). The best prediction formulas in each PPI were AUC(OPZ)=9.24 x C(6h)+2638.03, AUC(LPZ)=12.32 x C(6h)+3276.09 and AUC(RPZ)=1.39 x C(3h)+7.17 x C(6h)+344.14, respectively. In order to optimize the sampling strategy of LPZ, we tried to establish LSS for LPZ using a time point within 3 hours through the property of pharmacokinetics of its enantiomers. The best prediction formula using the fewest sampling points (one point) was AUC(racemic LPZ)=6.5 x C(3h) of (R)-LPZ+13.7 x C(3h) of (S)-LPZ-9917.3 x G1-14387.2×G2+7103.6 (G1: homozygous extensive metabolizer is 1 and the other genotypes are 0; G2: heterozygous extensive metabolizer is 1 and the other genotypes are 0). Those strategies, plasma concentration monitoring at one or two time-points, might be more suitable for AUC estimation than reference to CYP2C19 genotypes, particularly in the case of coadministration of CYP mediators.

  15. An extension of the receiver operating characteristic curve and AUC-optimal classification.

    Science.gov (United States)

    Takenouchi, Takashi; Komori, Osamu; Eguchi, Shinto

    2012-10-01

    While most proposed methods for solving classification problems focus on minimization of the classification error rate, we are interested in the receiver operating characteristic (ROC) curve, which provides more information about classification performance than the error rate does. The area under the ROC curve (AUC) is a natural measure for overall assessment of a classifier based on the ROC curve. We discuss a class of concave functions for AUC maximization in which a boosting-type algorithm including RankBoost is considered, and the Bayesian risk consistency and the lower bound of the optimum function are discussed. A procedure derived by maximizing a specific optimum function has high robustness, based on gross error sensitivity. Additionally, we focus on the partial AUC, which is the partial area under the ROC curve. For example, in medical screening, a high true-positive rate to the fixed lower false-positive rate is preferable and thus the partial AUC corresponding to lower false-positive rates is much more important than the remaining AUC. We extend the class of concave optimum functions for partial AUC optimality with the boosting algorithm. We investigated the validity of the proposed method through several experiments with data sets in the UCI repository.

  16. The cross-validated AUC for MCP-logistic regression with high-dimensional data.

    Science.gov (United States)

    Jiang, Dingfeng; Huang, Jian; Zhang, Ying

    2013-10-01

    We propose a cross-validated area under the receiving operator characteristic (ROC) curve (CV-AUC) criterion for tuning parameter selection for penalized methods in sparse, high-dimensional logistic regression models. We use this criterion in combination with the minimax concave penalty (MCP) method for variable selection. The CV-AUC criterion is specifically designed for optimizing the classification performance for binary outcome data. To implement the proposed approach, we derive an efficient coordinate descent algorithm to compute the MCP-logistic regression solution surface. Simulation studies are conducted to evaluate the finite sample performance of the proposed method and its comparison with the existing methods including the Akaike information criterion (AIC), Bayesian information criterion (BIC) or Extended BIC (EBIC). The model selected based on the CV-AUC criterion tends to have a larger predictive AUC and smaller classification error than those with tuning parameters selected using the AIC, BIC or EBIC. We illustrate the application of the MCP-logistic regression with the CV-AUC criterion on three microarray datasets from the studies that attempt to identify genes related to cancers. Our simulation studies and data examples demonstrate that the CV-AUC is an attractive method for tuning parameter selection for penalized methods in high-dimensional logistic regression models.

  17. Discrimination measures for survival outcomes: connection between the AUC and the predictiveness curve.

    Science.gov (United States)

    Viallon, Vivian; Latouche, Aurélien

    2011-03-01

    Finding out biomarkers and building risk scores to predict the occurrence of survival outcomes is a major concern of clinical epidemiology, and so is the evaluation of prognostic models. In this paper, we are concerned with the estimation of the time-dependent AUC--area under the receiver-operating curve--which naturally extends standard AUC to the setting of survival outcomes and enables to evaluate the discriminative power of prognostic models. We establish a simple and useful relation between the predictiveness curve and the time-dependent AUC--AUC(t). This relation confirms that the predictiveness curve is the key concept for evaluating calibration and discrimination of prognostic models. It also highlights that accurate estimates of the conditional absolute risk function should yield accurate estimates for AUC(t). From this observation, we derive several estimators for AUC(t) relying on distinct estimators of the conditional absolute risk function. An empirical study was conducted to compare our estimators with the existing ones and assess the effect of model misspecification--when estimating the conditional absolute risk function--on the AUC(t) estimation. We further illustrate the methodology on the Mayo PBC and the VA lung cancer data sets. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. ACCURACY OF PLASMA FREE METANEPHRINES IN THE DIAGNOSIS OF PHEOCHROMOCYTOMA AND PARAGANGLIOMA: A SYSTEMATIC REVIEW AND META-ANALYSIS.

    Science.gov (United States)

    Chen, Yan; Xiao, Huangmeng; Zhou, Xieda; Huang, Xiaoyu; Li, Yanbing; Xiao, Haipeng; Cao, Xiaopei

    2017-10-01

    Various studies have validated plasma free metanephrines (MNs) as biomarkers for pheochromocytoma and paraganglioma (PPGL). This meta-analysis aimed to estimate the overall diagnostic accuracy of this biochemical test for PPGL. We searched the PubMed, the Cochrane Library, Web of Science, Embase, Scopus, OvidSP, and ProQuest Dissertations & Theses databases from January 1, 1995 to December 2, 2016 and selected studies written in English that assessed plasma free MNs in the diagnosis of PPGL. Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) was used to evaluate the quality of the included studies. We calculated pooled sensitivities, specificities, positive and negative likelihood ratios, diagnostic odds ratios (DORs) and areas under curve (AUCs) with their 95% confidence intervals (95% CIs). Heterogeneity was assessed by I 2 . To identify the source of heterogeneity, we evaluated the threshold effect and performed a meta-regression. Deeks' funnel plot was selected for investigating any potential publication bias. Although the combination of metanephrine (MN) and normetanephrine (NMN) carried lower specificity (0.94, 95% CI 0.90-0.97) than NMN (0.97, 95% CI 0.92-0.99), NMN was generally more accurate than individual tests, with the highest AUC (0.99, 95% CI 0.97-0.99), DOR (443.35, 95% CI 216.9-906.23), and pooled sensitivity (0.97, 95% CI 0.94-0.98) values. Threshold effect and meta-regression analyses showed that different cut-offs, blood sampling positions, study types and test methods contributed to heterogeneity. This meta-analysis suggested an effective value for combined plasma free MNs for the diagnosis of PPGL, but testing for MNs requires more standardization using tightly regulated studies. AUC = area under curve; CI = confidence interval; DOR = diagnostic odds ratio; EIA = enzyme immunoassay; LC-ECD = liquid chromatography-electrochemical detection; LC-MS/MS = liquid chromatography-tandem mass spectrometry; MN = metanephrine; NMN

  19. Do technical parameters affect the diagnostic accuracy of virtual bronchoscopy in patients with suspected airways stenosis?

    International Nuclear Information System (INIS)

    Jones, Catherine M.; Athanasiou, Thanos; Nair, Sujit; Aziz, Omer; Purkayastha, Sanjay; Konstantinos, Vlachos; Paraskeva, Paraskevas; Casula, Roberto; Glenville, Brian; Darzi, Ara

    2005-01-01

    Purpose: Virtual bronchoscopy has gained popularity over the past decade as an alternative investigation to conventional bronchoscopy in the diagnosis, grading and monitoring of airway disease. The effect of technical parameters on diagnostic outcome from virtual bronchoscopy has not been determined. This meta-analysis aims to estimate accuracy of virtual compared to conventional bronchoscopy in patients with suspected airway stenosis, and evaluate the influence of technical parameters. Materials and methods: A MEDLINE search was used to identify relevant published studies. The primary endpoint was the 'correct diagnosis' of stenotic lesions on virtual compared to conventional bronchoscopy. Secondary endpoints included the effects of the technical parameters (pitch, collimation, reconstruction interval, rendering method, and scanner type), and date of publication on the diagnostic accuracy of virtual bronchoscopy. Results: Thirteen studies containing 454 patients were identified. Meta-analysis showed good overall diagnostic performance with 85% calculated pooled sensitivity (95% CI 77-91%), 87% specificity (95% CI 81-92%) and area under the curve (AUC) of 0.947. Subgroups included collimation of 3 mm or more (AUC 0.948), pitch of 1 (AUC 0.955), surface rendering technique (AUC 0.935), and reconstruction interval of more than 1.25 mm (AUC 0.914). There was no significant difference in accuracy accounting for publication date, scanner type or any of the above variables. Weighted regression analysis confirmed none of these variables could significantly account for study heterogeneity. Conclusion: Virtual bronchoscopy performs well in the investigation of patients with suspected airway stenosis. Overall sensitivity and specificity and diagnostic odds ratio for diagnosis of airway stenosis were high. The effects of pitch, collimation, reconstruction interval, rendering technique, scanner type, and publication date on diagnostic accuracy were not significant

  20. 78 FR 51753 - AUC, LLC Reno Creek, In Situ Project, New Source Material License Application

    Science.gov (United States)

    2013-08-21

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 040-09092; [NRC-2013-0164] AUC, LLC Reno Creek, In Situ..., AUC, LLC (AUC) submitted to the U.S. Nuclear Regulatory Commission (NRC) an application for a new... and operation, and decommissioning of AUC's proposed in-situ uranium recovery (ISR, also known as in...

  1. Application of the piecewise rational quadratic interpolant to the AUC calculation in the bioavailability study.

    Science.gov (United States)

    Akhter, Khalid P; Ahmad, Mahmood; Khan, Shujaat Ali; Ramzan, Munazza; Shafi, Ishrat; Muryam, Burhana; Javed, Zafar; Murtaza, Ghulam

    2012-01-01

    This study presents an application of the piecewise rational quadratic interpolant to the AUC calculation in the bioavailability study. The objective of this work is to find an area under the plasma concentration-time curve (AUC) for multiple doses of salbutamol sulfate sustained release tablets (Ventolin oral tablets SR 8 mg, GSK, Pakistan) in the group of 24 healthy adults by using computational mathematics techniques. Following the administration of 4 doses of Ventolin tablets 12 hourly to 24 healthy human subjects and bioanalysis of obtained plasma samples, plasma drug concentration-time profile was constructed. The approximated AUC was computed by using computational mathematics techniques such as extended rectangular, extended trapezium and extended Simpson's rule and compared with exact value of AUC calculated by using software - Kinetica to find best computational mathematics method that gives AUC values closest to exact. The exact values of AUC for four consecutive doses of Ventolin oral tablets were 150.58, 157.81, 164.41 and 162.78 ngxh/mL while the closest approximated AUC values were 149.24, 157.33, 164.25 and 162.28 ngxh/mL, respectively, as found by extended rectangular rule. The errors in the approximated values of AUC were negligible. It is concluded that all computational tools approximated values of AUC accurately but the extended rectangular rule gives slightly better approximated values of AUC as compared to extended trapezium and extended Simpson's rules.

  2. Carboplatin AUC 10 for IGCCCG good prognosis metastatic seminoma.

    Science.gov (United States)

    Tookman, Laura; Rashid, Sukaina; Matakidou, Athena; Phillips, Melissa; Wilson, Peter; Ansell, Wendy; Jamal-Hanjani, Mariam; Chowdhury, Simon; Harland, Stephen; Sarwar, Naveed; Oliver, Timothy; Powles, Thomas; Shamash, Jonathan

    2013-06-01

    Metastatic seminoma is a highly curable disease. Standard treatment comprises of combination chemotherapy. The short- and long-term toxicities of this treatment are increasingly recognised and the possibility of over treatment in such a curable disease should be considered. We have therefore assessed the use of single agent carboplatin at a dose of AUC 10 in patients with good prognosis metastatic seminoma. Patients with good prognosis metastatic seminoma treated with carboplatin (AUC 10) were identified at our institution and affiliated institutions. Treatment was three weekly for a total of three or four cycles. Outcome and toxicities were analysed. With a median follow-up of 36 months, 61 patients in total were treated with carboplatin AUC 10, all good prognosis by the IGCCCG criteria. Forty-eight percent had stage IIA/IIB disease and 52% had greater than stage IIB disease. Thirty-one patients (51%) had a complete response following treatment. Three-year survival was 96.3% with a three-year progression free survival of 93.2%. The main treatment toxicity was haematological with 46% having grade 3, 24% having grade 4 neutropenia and 54% experiencing grade 3/4 thrombocytopenia. There were no treatment related deaths. Single agent carboplatin at a dose of AUC 10 is an effective treatment for good prognosis metastatic seminoma. The outcome compares favourably to previously published outcomes of combination chemotherapy. Although haematological toxicity is a concern, single agent carboplatin treatment for good prognosis metastatic seminoma could be considered a treatment option and is associated with less toxicity than combination regimens currently used.

  3. An AUC-based permutation variable importance measure for random forests.

    Science.gov (United States)

    Janitza, Silke; Strobl, Carolin; Boulesteix, Anne-Laure

    2013-04-05

    The random forest (RF) method is a commonly used tool for classification with high dimensional data as well as for ranking candidate predictors based on the so-called random forest variable importance measures (VIMs). However the classification performance of RF is known to be suboptimal in case of strongly unbalanced data, i.e. data where response class sizes differ considerably. Suggestions were made to obtain better classification performance based either on sampling procedures or on cost sensitivity analyses. However to our knowledge the performance of the VIMs has not yet been examined in the case of unbalanced response classes. In this paper we explore the performance of the permutation VIM for unbalanced data settings and introduce an alternative permutation VIM based on the area under the curve (AUC) that is expected to be more robust towards class imbalance. We investigated the performance of the standard permutation VIM and of our novel AUC-based permutation VIM for different class imbalance levels using simulated data and real data. The results suggest that the new AUC-based permutation VIM outperforms the standard permutation VIM for unbalanced data settings while both permutation VIMs have equal performance for balanced data settings. The standard permutation VIM loses its ability to discriminate between associated predictors and predictors not associated with the response for increasing class imbalance. It is outperformed by our new AUC-based permutation VIM for unbalanced data settings, while the performance of both VIMs is very similar in the case of balanced classes. The new AUC-based VIM is implemented in the R package party for the unbiased RF variant based on conditional inference trees. The codes implementing our study are available from the companion website: http://www.ibe.med.uni-muenchen.de/organisation/mitarbeiter/070_drittmittel/janitza/index.html.

  4. Vancomycin AUC/MIC ratio and 30-day mortality in patients with Staphylococcus aureus bacteremia.

    Science.gov (United States)

    Holmes, Natasha E; Turnidge, John D; Munckhof, Wendy J; Robinson, J Owen; Korman, Tony M; O'Sullivan, Matthew V N; Anderson, Tara L; Roberts, Sally A; Warren, Sanchia J C; Gao, Wei; Howden, Benjamin P; Johnson, Paul D R

    2013-04-01

    A ratio of the vancomycin area under the concentration-time curve to the MIC (AUC/MIC) of ≥ 400 has been associated with clinical success when treating Staphylococcus aureus pneumonia, and this target was recommended by recently published vancomycin therapeutic monitoring consensus guidelines for treating all serious S. aureus infections. Here, vancomycin serum trough levels and vancomycin AUC/MIC were evaluated in a "real-world" context by following a cohort of 182 patients with S. aureus bacteremia (SAB) and analyzing these parameters within the critical first 96 h of vancomycin therapy. The median vancomycin trough level at this time point was 19.5 mg/liter. There was a significant difference in vancomycin AUC/MIC when using broth microdilution (BMD) compared with Etest MIC (medians of 436.1 and 271.5, respectively; P AUC/MIC of ≥ 400 using BMD was not associated with lower 30-day all-cause or attributable mortality from SAB (P = 0.132 and P = 0.273, respectively). However, an alternative vancomycin AUC/MIC of >373, derived using classification and regression tree analysis, was associated with reduced mortality (P = 0.043) and remained significant in a multivariable model. This study demonstrated that we obtained vancomycin trough levels in the target therapeutic range early during the course of therapy and that obtaining a higher vancomycin AUC/MIC (in this case, >373) within 96 h was associated with reduced mortality. The MIC test method has a significant impact on vancomycin AUC/MIC estimation. Clinicians should be aware that the current target AUC/MIC of ≥ 400 was derived using the reference BMD method, so adjustments to this target need to be made when calculating AUC/MIC ratio using other MIC testing methods.

  5. Study of stripping cristallization processus of AUC with ammonium carbonate

    International Nuclear Information System (INIS)

    Chegrouche, Salah.

    1987-09-01

    This study is concerned with direct crystallization of ammonium uranyl carbonate (AUC) from a uranium loaded organic phase (30% TBP in kerosene), with ammonium carbonate (NH 4 ) 2 CO 3 . The effects of operating conditions ((NH 4 ) 2 CO 3 concentration, flow-ratio, residence time, temperature) on the physical properties of AUC crystals (particle size distribution, specific surface, density...) are reported. All products were identified (both by chemical analysis, X-Ray diffraction) as being ammonium uranyl carbonate crystals (AUC). The results show that a high phase ratio and (NH 4 ) 2 CO 3 concentration favor the formation of fine AUC grains and aggregates. This is due mainly to the high concentration of NH + 4 in the system which leads to a high solution supersaturation and consequently to a rapid formation rate of crystal (germination). The reverse phenomenon is observed at low phase ratio and (NH 4 ) 2 CO 3 concentration, where germination and crystal growth are slow and the product is mainly monocrystal. In the intermediate range, a mixture of polycrystal and aggregates is obtained. Residence and temperature are also shown to have an effect on the processes (the effect of time being more important than temperature). In the course of this study a bench-scale stripper-crystallizer was developped and operated successfully. (author). tables, graphs

  6. AUC-based biomarker ensemble with an application on gene scores predicting low bone mineral density.

    Science.gov (United States)

    Zhao, X G; Dai, W; Li, Y; Tian, L

    2011-11-01

    The area under the receiver operating characteristic (ROC) curve (AUC), long regarded as a 'golden' measure for the predictiveness of a continuous score, has propelled the need to develop AUC-based predictors. However, the AUC-based ensemble methods are rather scant, largely due to the fact that the associated objective function is neither continuous nor concave. Indeed, there is no reliable numerical algorithm identifying optimal combination of a set of biomarkers to maximize the AUC, especially when the number of biomarkers is large. We have proposed a novel AUC-based statistical ensemble methods for combining multiple biomarkers to differentiate a binary response of interest. Specifically, we propose to replace the non-continuous and non-convex AUC objective function by a convex surrogate loss function, whose minimizer can be efficiently identified. With the established framework, the lasso and other regularization techniques enable feature selections. Extensive simulations have demonstrated the superiority of the new methods to the existing methods. The proposal has been applied to a gene expression dataset to construct gene expression scores to differentiate elderly women with low bone mineral density (BMD) and those with normal BMD. The AUCs of the resulting scores in the independent test dataset has been satisfactory. Aiming for directly maximizing AUC, the proposed AUC-based ensemble method provides an efficient means of generating a stable combination of multiple biomarkers, which is especially useful under the high-dimensional settings. lutian@stanford.edu. Supplementary data are available at Bioinformatics online.

  7. Interactive dedicated training curriculum improves accuracy in the interpretation of MR imaging of prostate cancer

    International Nuclear Information System (INIS)

    Akin, Oguz; Zhang, Jingbo; Hricak, Hedvig; Riedl, Christopher C.; Ishill, Nicole M.; Moskowitz, Chaya S.

    2010-01-01

    To assess the effect of interactive dedicated training on radiology fellows' accuracy in assessing prostate cancer on MRI. Eleven radiology fellows, blinded to clinical and pathological data, independently interpreted preoperative prostate MRI studies, scoring the likelihood of tumour in the peripheral and transition zones and extracapsular extension. Each fellow interpreted 15 studies before dedicated training (to supply baseline interpretation accuracy) and 200 studies (10/week) after attending didactic lectures. Expert radiologists led weekly interactive tutorials comparing fellows' interpretations to pathological tumour maps. To assess interpretation accuracy, receiver operating characteristic (ROC) analysis was conducted, using pathological findings as the reference standard. In identifying peripheral zone tumour, fellows' average area under the ROC curve (AUC) increased from 0.52 to 0.66 (after didactic lectures; p < 0.0001) and remained at 0.66 (end of training; p < 0.0001); in the transition zone, their average AUC increased from 0.49 to 0.64 (after didactic lectures; p = 0.01) and to 0.68 (end of training; p = 0.001). In detecting extracapsular extension, their average AUC increased from 0.50 to 0.67 (after didactic lectures; p = 0.003) and to 0.81 (end of training; p < 0.0001). Interactive dedicated training significantly improved accuracy in tumour localization and especially in detecting extracapsular extension on prostate MRI. (orig.)

  8. Interactive dedicated training curriculum improves accuracy in the interpretation of MR imaging of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Akin, Oguz; Zhang, Jingbo; Hricak, Hedvig [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York, NY (United States); Riedl, Christopher C. [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York, NY (United States); Medical University of Vienna, Department of Radiology, Vienna (Austria); Ishill, Nicole M.; Moskowitz, Chaya S. [Memorial Sloan-Kettering Cancer Center, Epidemiology and Biostatistics, New York, NY (United States)

    2010-04-15

    To assess the effect of interactive dedicated training on radiology fellows' accuracy in assessing prostate cancer on MRI. Eleven radiology fellows, blinded to clinical and pathological data, independently interpreted preoperative prostate MRI studies, scoring the likelihood of tumour in the peripheral and transition zones and extracapsular extension. Each fellow interpreted 15 studies before dedicated training (to supply baseline interpretation accuracy) and 200 studies (10/week) after attending didactic lectures. Expert radiologists led weekly interactive tutorials comparing fellows' interpretations to pathological tumour maps. To assess interpretation accuracy, receiver operating characteristic (ROC) analysis was conducted, using pathological findings as the reference standard. In identifying peripheral zone tumour, fellows' average area under the ROC curve (AUC) increased from 0.52 to 0.66 (after didactic lectures; p < 0.0001) and remained at 0.66 (end of training; p < 0.0001); in the transition zone, their average AUC increased from 0.49 to 0.64 (after didactic lectures; p = 0.01) and to 0.68 (end of training; p = 0.001). In detecting extracapsular extension, their average AUC increased from 0.50 to 0.67 (after didactic lectures; p = 0.003) and to 0.81 (end of training; p < 0.0001). Interactive dedicated training significantly improved accuracy in tumour localization and especially in detecting extracapsular extension on prostate MRI. (orig.)

  9. Bayesian modeling and inference for diagnostic accuracy and probability of disease based on multiple diagnostic biomarkers with and without a perfect reference standard.

    Science.gov (United States)

    Jafarzadeh, S Reza; Johnson, Wesley O; Gardner, Ian A

    2016-03-15

    The area under the receiver operating characteristic (ROC) curve (AUC) is used as a performance metric for quantitative tests. Although multiple biomarkers may be available for diagnostic or screening purposes, diagnostic accuracy is often assessed individually rather than in combination. In this paper, we consider the interesting problem of combining multiple biomarkers for use in a single diagnostic criterion with the goal of improving the diagnostic accuracy above that of an individual biomarker. The diagnostic criterion created from multiple biomarkers is based on the predictive probability of disease, conditional on given multiple biomarker outcomes. If the computed predictive probability exceeds a specified cutoff, the corresponding subject is allocated as 'diseased'. This defines a standard diagnostic criterion that has its own ROC curve, namely, the combined ROC (cROC). The AUC metric for cROC, namely, the combined AUC (cAUC), is used to compare the predictive criterion based on multiple biomarkers to one based on fewer biomarkers. A multivariate random-effects model is proposed for modeling multiple normally distributed dependent scores. Bayesian methods for estimating ROC curves and corresponding (marginal) AUCs are developed when a perfect reference standard is not available. In addition, cAUCs are computed to compare the accuracy of different combinations of biomarkers for diagnosis. The methods are evaluated using simulations and are applied to data for Johne's disease (paratuberculosis) in cattle. Copyright © 2015 John Wiley & Sons, Ltd.

  10. A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation.

    Directory of Open Access Journals (Sweden)

    Huaying Zhao

    Full Text Available Analytical ultracentrifugation (AUC is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188 S (4.4%. After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%. In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies.

  11. A Multilaboratory Comparison of Calibration Accuracy and the Performance of External References in Analytical Ultracentrifugation

    KAUST Repository

    Zhao, Huaying

    2015-05-21

    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies.

  12. A Multilaboratory Comparison of Calibration Accuracy and the Performance of External References in Analytical Ultracentrifugation

    KAUST Repository

    Zhao, Huaying; Ghirlando, Rodolfo; Alfonso, Carlos; Arisaka, Fumio; Attali, Ilan; Bain, David L.; Bakhtina, Marina M.; Becker, Donald F.; Bedwell, Gregory J.; Bekdemir, Ahmet; Besong, Tabot M.D.; Birck, Catherine; Brautigam, Chad A.; Brennerman, William; Byron, Olwyn; Bzowska, Agnieszka; Chaires, Jonathan B.; Chaton, Catherine T.; Cö lfen, Helmut; Connaghan, Keith D.; Crowley, Kimberly A.; Curth, Ute; Daviter, Tina; Dean, William L.; Dí ez, Ana I.; Ebel, Christine; Eckert, Debra M.; Eisele, Leslie E.; Eisenstein, Edward; England, Patrick; Escalante, Carlos; Fagan, Jeffrey A.; Fairman, Robert; Finn, Ron M.; Fischle, Wolfgang; de la Torre, José Garcí a; Gor, Jayesh; Gustafsson, Henning; Hall, Damien; Harding, Stephen E.; Cifre, José G. Herná ndez; Herr, Andrew B.; Howell, Elizabeth E.; Isaac, Richard S.; Jao, Shu-Chuan; Jose, Davis; Kim, Soon-Jong; Kokona, Bashkim; Kornblatt, Jack A.; Kosek, Dalibor; Krayukhina, Elena; Krzizike, Daniel; Kusznir, Eric A.; Kwon, Hyewon; Larson, Adam; Laue, Thomas M.; Le Roy, Aline; Leech, Andrew P.; Lilie, Hauke; Luger, Karolin; Luque-Ortega, Juan R.; Ma, Jia; May, Carrie A.; Maynard, Ernest L.; Modrak-Wojcik, Anna; Mok, Yee-Foong; Mü cke, Norbert; Nagel-Steger, Luitgard; Narlikar, Geeta J.; Noda, Masanori; Piszczek, Grzegorz; Nourse, Amanda; Obsil, Tomas; Park, Chad K.; Park, Jin-Ku; Pawelek, Peter D.; Perdue, Erby E.; Perkins, Stephen J.; Perugini, Matthew A.; Peterson, Craig L.; Peverelli, Martin G.; Prag, Gali; Prevelige, Peter E.; Raynal, Bertrand D. E.; Rezabkova, Lenka; Richter, Klaus; Ringel, Alison E.; Rosenberg, Rose; Rowe, Arthur J.; Rufer, Arne C.; Swygert, Sarah G.; Scott, David J.; Seravalli, Javier G.; Solovyova, Alexandra S.; Song, Renjie; Staunton, David; Stoddard, Caitlin; Stott, Katherine; Strauss, Holger M.; Streicher, Werner W.; Sumida, John P.; Szczepanowski, Roman H.; Tessmer, Ingrid; Toth, Ronald T.; Tripathy, Ashutosh; Uchiyama, Susumu; Uebel, Stephan F. W.; Unzai, Satoru; Gruber, Anna Vitlin; von Hippel, Peter H.; null; Wandrey, Christine; Wang, Szu-Huan; Weitzel, Steven E.; Wielgus-Kutrowska, Beata; Wolberger, Cynthia; Wolff, Martin; Wright, Edward; Wu, Yu-Sung; Wubben, Jacinta M.; Schuck, Peter

    2015-01-01

    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies.

  13. The Relationship Between Vancomycin Trough Concentrations and AUC/MIC Ratios in Pediatric Patients: A Qualitative Systematic Review.

    Science.gov (United States)

    Tkachuk, Stacey; Collins, Kyle; Ensom, Mary H H

    2018-04-01

    In adults, the area under the concentration-time curve (AUC) divided by the minimum inhibitory concentration (MIC) is associated with better clinical and bacteriological response to vancomycin in patients with methicillin-resistant Staphylococcus aureus who achieve target AUC/MIC ≥ 400. This target is often extrapolated to pediatric patients despite the lack of similar evidence. The impracticalities of calculating the AUC in practice means vancomycin trough concentrations are used to predict the AUC/MIC. This review aimed to determine the relationship between vancomycin trough concentrations and AUC/MIC in pediatric patients. We searched the MEDLINE and Embase databases, the Cochrane Database of Systematic Reviews, and the Cochrane Central Register of Controlled Trials using the medical subject heading (MeSH) terms vancomycin and AUC and pediatric* or paediatric*. Articles were included if they were published in English and reported a relationship between vancomycin trough concentrations and AUC/MIC. Of 122 articles retrieved, 11 met the inclusion criteria. One trial reported a relationship between vancomycin trough concentrations, AUC/MIC, and clinical outcomes but was likely underpowered. Five studies found troughs 6-10 mg/l were sufficient to attain an AUC/MIC > 400 in most general hospitalized pediatric patients. One study in patients undergoing cardiothoracic surgery found a trough of 18.4 mg/l achieved an AUC/MIC > 400. Two oncology studies reported troughs ≥ 15 mg/l likely attained an AUC/MIC ≥ 400. In critical care patients: one study found a trough of 9 mg/l did not attain the AUC/MIC target; another found 7 mg/l corresponded to an AUC/MIC of 400. Potential vancomycin targets varied based on the population studied but, for general hospitalized pediatric patients, troughs of 6-10 mg/l are likely sufficient to achieve AUC/MIC ≥ 400. For MIC ≥ 2 mg/l, higher troughs are likely necessary to achieve an AUC/MIC ≥ 400. More

  14. Support for higher ciprofloxacin AUC 24/MIC targets in treating Enterobacteriaceae bloodstream infection.

    Science.gov (United States)

    Zelenitsky, Sheryl A; Ariano, Robert E

    2010-08-01

    Given concerns regarding optimal therapy for serious Gram-negative infections, the goal was to characterize the pharmacodynamics of ciprofloxacin in the context of treating bloodstream infection. Data were collected from the medical records of 178 clinical cases. Blood isolates were retrieved and ciprofloxacin MICs were measured. Forty-two cases in which ciprofloxacin was initiated within 24 h of the positive blood culture were used in the pharmacodynamic analysis. Significant factors with regard to treatment failure were low ciprofloxacin AUC(24)/MIC (P AUC(24) (P = 0.01). AUC(24)/MIC (P = 0.012) and MIC (P = 0.019) were significant variables in multivariate analyses; however, only the former remained significant (P = 0.038) after excluding two cases with ciprofloxacin-resistant isolates. An AUC(24)/MIC breakpoint of 250 was most significant, with cure rates of 91.4% (32/35) and 28.6% (2/7) in patients with values above and below this threshold, respectively (P = 0.001). The risk of ciprofloxacin treatment failure was 27.8 times (95% confidence interval, 2.1-333) greater in those not achieving an AUC(24)/MIC >or=250 (P = 0.011). Monte Carlo simulation of 5000 study subjects predicted that 0.88 of the population would achieve an AUC(24)/MIC >or=250 with standard-dose ciprofloxacin (400 mg intravenously every 12 h). This study confirms the pharmacodynamic parameters of ciprofloxacin that are important for optimizing the treatment of serious infections, particularly the benefits of achieving an AUC(24)/MIC >or=250, rather than the conventional target of >or=125. It also shows the relevance of dose selection in optimizing target attainment, with important differences among pathogens, even those with MICs within the susceptible range.

  15. Analysis of flux standards in a fluized bed for AUC - UO2 convertion

    International Nuclear Information System (INIS)

    Juanico, L.E.; Clausse, A.; Guido Lavalle, G.

    1990-01-01

    One of the fuel cycle stages is the convertion (reduction) of ammonium uranyl carbonate (AUC) in UO 2 which, after being directly compacted, allows pellet obtainment acquire the correct density to be used as nuclear fuel during sintering. AUC's reduction in UO 2 is made on a fluidized bed in which AUC powder going into the upper part at a countercurrent to the gas flux (superheated steam), is converted into UO 2 ; after the reaction, UO 2 is collected at the lower part of the reactor. (Author) [es

  16. Why Does Rebalancing Class-Unbalanced Data Improve AUC for Linear Discriminant Analysis?

    Science.gov (United States)

    Xue, Jing-Hao; Hall, Peter

    2015-05-01

    Many established classifiers fail to identify the minority class when it is much smaller than the majority class. To tackle this problem, researchers often first rebalance the class sizes in the training dataset, through oversampling the minority class or undersampling the majority class, and then use the rebalanced data to train the classifiers. This leads to interesting empirical patterns. In particular, using the rebalanced training data can often improve the area under the receiver operating characteristic curve (AUC) for the original, unbalanced test data. The AUC is a widely-used quantitative measure of classification performance, but the property that it increases with rebalancing has, as yet, no theoretical explanation. In this note, using Gaussian-based linear discriminant analysis (LDA) as the classifier, we demonstrate that, at least for LDA, there is an intrinsic, positive relationship between the rebalancing of class sizes and the improvement of AUC. We show that the largest improvement of AUC is achieved, asymptotically, when the two classes are fully rebalanced to be of equal sizes.

  17. Diagnostic accuracy of the parameters from ganglion cell complex map, evaluated with SD-OCT in primary open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    B. Anguelov

    2014-10-01

    Full Text Available Purpose: To evaluate the sensitivity and specificity of ganglion cell complex (GCC parameters, obtained with optical coherence tomography (OCT and to determine their accuracy and ability to differentiate healthy from primary open-angle glaucoma patients. Patients and methods. 84 eyes of primary open-angle glaucoma patients and 40 eyes of healthy individuals were enrolled in the study. All of them underwent complete eye examination, including standard automated perimetry (HFA II and OCT (RTVue-100. Avg. GCC (average GCC, Sup. GCC (superior GCC, Inf. GCC (inferior GCC, GLV (globаl loss volume, FLV (focal loss volume and RNFL (retinal nerve fiber layer — ONH map were measured. ROC curveswere created and sensitivity and specificity were calculated for each of these parameters.Results.The highest sensitivity and specificity was found for GLV and the lowest for Sup. GCC. Area under the ROC curves (AUC for GLV was found to be the largest and the smallest for Sup. GCC.Conclusion. Parameters from GCC map have high sensitivity and specificity. Their diagnostic capability is similar, even slightly better than the one of RNFL. GLV has the highest diagnostic accuracy for primary open-angle glaucoma detection in this study.

  18. Suitability of the AUC Ratio as an Indicator of the Pharmacokinetic Advantage in HIPEC.

    Science.gov (United States)

    Mas-Fuster, Maria Isabel; Ramon-Lopez, Amelia; Lacueva, Javier; Más-Serrano, Patricio; Nalda-Molina, Ricardo

    2018-02-01

    The purpose of this study was to evaluate the area under the concentration-time curve (AUC) ratio as an optimal indicator of the pharmacokinetic advantage during hyperthermic intraperitoneal perioperative chemotherapy. The impact on the AUC ratio on the variables related to the calculation of systemic drug exposure, instillation time, and peripheral drug distribution was evaluated through simulations as well as through a retrospective analysis of studies published in the literature. Both model simulations and the retrospective analysis showed that the 3 variables evaluated had an impact on the AUC ratio value if the complete systemic exposure was not fully considered. However, when that complete systemic exposure was considered, none of these variables affected the AUC ratio value. AUC ratio is not a characteristic parameter of a drug if the calculated systemic drug exposure is not complete. Thus, AUC ratio is not valid for comparing the pharmacokinetic advantage of 2 drugs, and it should not be employed to prove whether a drug can be used in hyperthermic intraperitoneal perioperative chemotherapy safely with regard to toxicity. As an alternative, the study of the absorption rate constant and the bioavailability are proposed as the true and independent parameters that reflect the amount of drug absorbed. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  19. AUC versus peak-trough dosing of vancomycin: applying new pharmacokinetic paradigms to an old drug.

    Science.gov (United States)

    Brown, Daniel L; Lalla, Christina D; Masselink, Andrew J

    2013-08-01

    To compare and contrast the pharmacokinetic/pharmacodynamic foundations of traditional "peak-trough" vancomycin dosing methods versus newer "area under the curve" (AUC) strategies. To propose a new AUC-based dosing chart for empirically determining an initial vancomycin dosing regimen designed to achieve a desired AUC24 using the minimum inhibitory concentration (MIC), creatinine clearance (CrCl), and vancomycin clearance (ClVanco). Peak-trough vancomycin dosing is designed to achieve a Cpeak of 20-40 mg/L and a Ctrough of 10-15 or 15-20 mg/L, depending on the severity of the infection and the nature of the pathogen. New treatment guidelines for vancomycin suggest that therapy should achieve an AUC24/MIC of ≥400. AUC-based vancomycin dosing derives the daily dose from ClVanco, MIC, and the desired AUC24/MIC, without consideration of the patient's weight. A vancomycin dosing chart is proposed that estimates ClVanco using the following formula developed by Matzke et al: ClVanco in L/h = [(CrClmL/min × 0.689) + 3.66] × 0.06, which simplifies to (CrClmL/min × 0.41) + 0.22. Two levels of dosing are included-high dose (Ctrough: 15-20 mg/L) and moderate dose (Ctrough: 10-15 mg/L). Although the chart has not been validated clinically, it represents the product of standard dosing equations that are used to determine a starting dosing regimen based on well-established vancomycin pharmacokinetic parameters. An understanding of pharmacokinetic and pharmacodynamic principles, including the relevance of AUC in relation to MIC, enables clinicians to make the best use of vancomycin dosing options. The proposed dosing chart is pharmacokinetically valid but has yet to be applied clinically. It provides a foundation for further study of how clinicians can determine an optimal AUC-based starting vancomycin dosing regimen without having to derive ClVanco or AUC24.

  20. The Q* Index: A Useful Global Measure of Dementia Screening Test Accuracy

    Directory of Open Access Journals (Sweden)

    A.J. Larner

    2015-06-01

    Full Text Available Background/Aims: Single, global or unitary, indicators of test diagnostic performance have intuitive appeal for clinicians. The Q* index, the point in receiver operating characteristic (ROC curve space closest to the ideal top left-hand corner and where test sensitivity and specificity are equal, is one such measure. Methods: Datasets from four pragmatic accuracy studies which examined the Mini-Mental State Examination, Addenbrooke's Cognitive Examination-Revised, Montreal Cognitive Assessment, Test Your Memory test, and Mini-Addenbrooke's Cognitive Examination were examined to calculate and compare the Q* index, the maximal correct classification accuracy, and the maximal Youden index, as well as the sensitivity and specificity at these cutoffs. Results: Tests ranked similarly for the Q* index and the area under the ROC curve (AUC ROC. The Q* index cutoff was more sensitive (and less specific than the maximal correct classification accuracy cutoff, and less sensitive (and more specific than the maximal Youden index cutoff. Conclusion: The Q* index may be a useful global parameter summarising the test accuracy of cognitive screening instruments, facilitating comparison between tests, and defining a possible test cutoff value. As the point of equal sensitivity and specificity, its use may be more intuitive and appealing for clinicians than AUC ROC.

  1. Accuracy test for link prediction in terms of similarity index: The case of WS and BA models

    Science.gov (United States)

    Ahn, Min-Woo; Jung, Woo-Sung

    2015-07-01

    Link prediction is a technique that uses the topological information in a given network to infer the missing links in it. Since past research on link prediction has primarily focused on enhancing performance for given empirical systems, negligible attention has been devoted to link prediction with regard to network models. In this paper, we thus apply link prediction to two network models: The Watts-Strogatz (WS) model and Barabási-Albert (BA) model. We attempt to gain a better understanding of the relation between accuracy and each network parameter (mean degree, the number of nodes and the rewiring probability in the WS model) through network models. Six similarity indices are used, with precision and area under the ROC curve (AUC) value as the accuracy metrics. We observe a positive correlation between mean degree and accuracy, and size independence of the AUC value.

  2. Reported estimates of diagnostic accuracy in ophthalmology conference abstracts were not associated with full-text publication.

    Science.gov (United States)

    Korevaar, Daniël A; Cohen, Jérémie F; Spijker, René; Saldanha, Ian J; Dickersin, Kay; Virgili, Gianni; Hooft, Lotty; Bossuyt, Patrick M M

    2016-11-01

    To assess whether conference abstracts that report higher estimates of diagnostic accuracy are more likely to reach full-text publication in a peer-reviewed journal. We identified abstracts describing diagnostic accuracy studies, presented between 2007 and 2010 at the Association for Research in Vision and Ophthalmology (ARVO) Annual Meeting. We extracted reported estimates of sensitivity, specificity, area under the receiver operating characteristic curve (AUC), and diagnostic odds ratio (DOR). Between May and July 2015, we searched MEDLINE and EMBASE to identify corresponding full-text publications; if needed, we contacted abstract authors. Cox regression was performed to estimate associations with full-text publication, where sensitivity, specificity, and AUC were logit transformed, and DOR was log transformed. A full-text publication was found for 226/399 (57%) included abstracts. There was no association between reported estimates of sensitivity and full-text publication (hazard ratio [HR] 1.09 [95% confidence interval {CI} 0.98, 1.22]). The same applied to specificity (HR 1.00 [95% CI 0.88, 1.14]), AUC (HR 0.91 [95% CI 0.75, 1.09]), and DOR (HR 1.01 [95% CI 0.94, 1.09]). Almost half of the ARVO conference abstracts describing diagnostic accuracy studies did not reach full-text publication. Studies in abstracts that mentioned higher accuracy estimates were not more likely to be reported in a full-text publication. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Asymptotic distribution of ∆AUC, NRIs, and IDI based on theory of U-statistics.

    Science.gov (United States)

    Demler, Olga V; Pencina, Michael J; Cook, Nancy R; D'Agostino, Ralph B

    2017-09-20

    The change in area under the curve (∆AUC), the integrated discrimination improvement (IDI), and net reclassification index (NRI) are commonly used measures of risk prediction model performance. Some authors have reported good validity of associated methods of estimating their standard errors (SE) and construction of confidence intervals, whereas others have questioned their performance. To address these issues, we unite the ∆AUC, IDI, and three versions of the NRI under the umbrella of the U-statistics family. We rigorously show that the asymptotic behavior of ∆AUC, NRIs, and IDI fits the asymptotic distribution theory developed for U-statistics. We prove that the ∆AUC, NRIs, and IDI are asymptotically normal, unless they compare nested models under the null hypothesis. In the latter case, asymptotic normality and existing SE estimates cannot be applied to ∆AUC, NRIs, or IDI. In the former case, SE formulas proposed in the literature are equivalent to SE formulas obtained from U-statistics theory if we ignore adjustment for estimated parameters. We use Sukhatme-Randles-deWet condition to determine when adjustment for estimated parameters is necessary. We show that adjustment is not necessary for SEs of the ∆AUC and two versions of the NRI when added predictor variables are significant and normally distributed. The SEs of the IDI and three-category NRI should always be adjusted for estimated parameters. These results allow us to define when existing formulas for SE estimates can be used and when resampling methods such as the bootstrap should be used instead when comparing nested models. We also use the U-statistic theory to develop a new SE estimate of ∆AUC. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Higher capecitabine AUC in elderly patients with advanced colorectal cancer (SWOGS0030).

    Science.gov (United States)

    Louie, S G; Ely, B; Lenz, H-J; Albain, K S; Gotay, C; Coleman, D; Raghavan, D; Shields, A F; Gold, P J; Blanke, C D

    2013-10-01

    The aging process is accompanied by physiological changes including reduced glomerular filtration and hepatic function, as well as changes in gastric secretions. To investigate what effect would aging have on the disposition of capecitabine and its metabolites, the pharmacokinetics between patients ≥70 years and AUC) was accompanied by reduction in capecitabine clearance in ≥70 years patients (PAUCs between the two age groups, suggesting that carboxylesterase and cytidine deaminase (CDA) activity was similar between the two age groups. These results suggest that metabolic enzymes involved in converting capecitabine metabolites are not altered by age. An elevation in capecitabine Cmax and reduction in clearance was seen in females, where capecitabine AUC was 40.3% higher in women. Elevation of DFUR Cmax (45%) and AUC (46%) (PAUC was observed in patients ≥70 years when compared with younger patients who were >60 years.

  5. The Impact of AUC-Based Monitoring on Pharmacist-Directed Vancomycin Dose Adjustments in Complicated Methicillin-Resistant Staphylococcus aureus Infection.

    Science.gov (United States)

    Stoessel, Andrew M; Hale, Cory M; Seabury, Robert W; Miller, Christopher D; Steele, Jeffrey M

    2018-01-01

    This study aimed to assess the impact of area under the curve (AUC)-based vancomycin monitoring on pharmacist-initiated dose adjustments after transitioning from a trough-only to an AUC-based monitoring method at our institution. A retrospective cohort study of patients treated with vancomycin for complicated methicillin-resistant Staphylococcus aureus (MRSA) infection between November 2013 and December 2016 was conducted. The frequency of pharmacist-initiated dose adjustments was assessed for patients monitored via trough-only and AUC-based approaches for trough ranges: 10 to 14.9 mg/L and 15 to 20 mg/L. Fifty patients were included: 36 in the trough-based monitoring and 14 in the AUC-based-monitoring group. The vancomycin dose was increased in 71.4% of patients when troughs were 10 to 14.9 mg/L when a trough-only approach was used and in only 25% of patients when using AUC estimation ( P = .048). In the AUC group, the dose was increased only when AUC/minimum inhibitory concentration (MIC) AUC/MIC ≥400. The AUC-based monitoring did not significantly increase the frequency of dose reductions when trough concentrations were 15 to 20 mg/L (AUC: 33.3% vs trough: 4.6%; P = .107). The AUC-based monitoring resulted in fewer patients with dose adjustments when trough levels were 10 to 14.9 mg/L. The AUC-based monitoring has the potential to reduce unnecessary vancomycin exposure and warrants further investigation.

  6. Balancing vancomycin efficacy and nephrotoxicity: should we be aiming for trough or AUC/MIC?

    Science.gov (United States)

    Patel, Karisma; Crumby, Ashley S; Maples, Holly D

    2015-04-01

    Sixty years later, the question that still remains is how to appropriately utilize vancomycin in the pediatric population. The Infectious Diseases Society of America published guidelines in 2011 that provide guidance for dosing and monitoring of vancomycin in adults and pediatrics. However, goal vancomycin trough concentrations of 15-20 μg/mL for invasive infections caused by methicillin-resistant Staphylococcus aureus were based primarily on adult pharmacokinetic and pharmacodynamic data that achieved an area under the curve to minimum inhibitory concentration ratio (AUC/MIC) of ≥400. Recent pediatric literature shows that vancomycin trough concentrations needed to achieve the target AUC/MIC are different than the adult goal troughs cited in the guidelines. This paper addresses several thoughts, including the role of vancomycin AUC/MIC in dosing strategies and safety monitoring, consistency in laboratory reporting, and future directions for calculating AUC/MIC in pediatrics.

  7. Interethnic differences in the accuracy of anthropometric indicators of obesity in screening for high risk of coronary heart disease

    Science.gov (United States)

    Herrera, VM; Casas, JP; Miranda, JJ; Perel, P; Pichardo, R; González, A; Sanchez, JR; Ferreccio, C; Aguilera, X; Silva, E; Oróstegui, M; Gómez, LF; Chirinos, JA; Medina-Lezama, J; Pérez, CM; Suárez, E; Ortiz, AP; Rosero, L; Schapochnik, N; Ortiz, Z; Ferrante, D; Diaz, M; Bautista, LE

    2009-01-01

    Background Cut points for defining obesity have been derived from mortality data among Whites from Europe and the United States and their accuracy to screen for high risk of coronary heart disease (CHD) in other ethnic groups has been questioned. Objective To compare the accuracy and to define ethnic and gender-specific optimal cut points for body mass index (BMI), waist circumference (WC) and waist-to-hip ratio (WHR) when they are used in screening for high risk of CHD in the Latin-American and the US populations. Methods We estimated the accuracy and optimal cut points for BMI, WC and WHR to screen for CHD risk in Latin Americans (n=18 976), non-Hispanic Whites (Whites; n=8956), non-Hispanic Blacks (Blacks; n=5205) and Hispanics (n=5803). High risk of CHD was defined as a 10-year risk ≥20% (Framingham equation). The area under the receiver operator characteristic curve (AUC) and the misclassification-cost term were used to assess accuracy and to identify optimal cut points. Results WHR had the highest AUC in all ethnic groups (from 0.75 to 0.82) and BMI had the lowest (from 0.50 to 0.59). Optimal cut point for BMI was similar across ethnic/gender groups (27 kg/m2). In women, cut points for WC (94 cm) and WHR (0.91) were consistent by ethnicity. In men, cut points for WC and WHR varied significantly with ethnicity: from 91 cm in Latin Americans to 102 cm in Whites, and from 0.94 in Latin Americans to 0.99 in Hispanics, respectively. Conclusion WHR is the most accurate anthropometric indicator to screen for high risk of CHD, whereas BMI is almost uninformative. The same BMI cut point should be used in all men and women. Unique cut points for WC and WHR should be used in all women, but ethnic-specific cut points seem warranted among men. PMID:19238159

  8. Diagnostic accuracy of urinary biomarkers in infants younger than 3 months with urinary tract infection

    Science.gov (United States)

    Jung, Nani; Byun, Hye Jin; Park, Jae Hyun; Kim, Joon Sik; Kim, Hae Won

    2018-01-01

    Purpose The aim of this study was to evaluate the diagnostic accuracy of urinary biomarkers, such as neutrophil gelatinase-associated lipocalin (uNGAL) and β-2 microglobulin (uB2MG), in early detection of urinary tract infection (UTI) in infants aged UTI and non-UTI groups at the time of admission. The sensitivity, specificity, accuracy, and area under the curve (AUC) of uNGAL and uB2MG for use in diagnosing UTI were assessed. Results Among 422 patients, 102 (24.2%) were diagnosed with UTI. Levels of uNGAL were higher in the UTI group than in the non-UTI group (366.6 ng/mL vs. 26.9 ng/mL, PUTI (P=0.033). The sensitivity, specificity, and accuracy were 90.2%, 92.5%, and 91.9% for uNGAL, and 48.0%, 43.8%, and 44.8% for uB2MG, respectively. AUC of uNGAL was 0.942 and that of uB2MG was 0.407. Conclusion Accuracy of uNGAL in the diagnosis of UTI is high in febrile infants aged UTI in infants. PMID:29441109

  9. Characterisation and compaction behaviour of UO2 powder prepared from ADU and AUC

    International Nuclear Information System (INIS)

    Rachmawati, M.

    2000-01-01

    UO 2 powder prepared from ADU and AUC route process are characterised primarily in terms of compaction and sintering behaviour. Scientific understanding of the phenomena will give useful information leading to processing and product improvement. The investigation has been done by characterising the particle size/shape distribution using SEM and compacting the powder at 4 and 5.4 tons/cm 2 . The behaviour of the powder under compaction is observed by characterizing the pellet length, green density, microstructure, and the compression strength using micrometer SEM, and Universal Testing Machine. The results of the experiment show that the UO 2 powder ex-AUC has particles of spherical type and separate individually which provide the flowable characteristic, important for the die filling aspect during compaction step. The UO 2 powder ex-ADU is more or less agglomerated and contains very fine particles causing the difficulty in pressing. Therefore the green density resulted from UO 2 ex-AUC (6.415 g/cm 3 ) is higher than UO 2 powder of UO 2 ex-ADU (6.117 g/cm 3 . UO 2 at lower pressure (4 tons/cm 3 ) the compression strength ex-AUC green pellet (47.144 kgf) is lower than UO 2 ex-ADU (63,364 kgf), and at higher temperature the compression strength of ex-AUC (92.86 kgf) is higher than UO 2 ex-ADU (82.664 kgf). It is suggested that UO 2 ex-ADU has to be precompacted and granulated in order to increase its flowability so that the pellet length can easily be controlled during pressing (improve reproducibility). (author)

  10. Peak Measurement for Vancomycin AUC Estimation in Obese Adults Improves Precision and Lowers Bias.

    Science.gov (United States)

    Pai, Manjunath P; Hong, Joseph; Krop, Lynne

    2017-04-01

    Vancomycin area under the curve (AUC) estimates may be skewed in obese adults due to weight-dependent pharmacokinetic parameters. We demonstrate that peak and trough measurements reduce bias and improve the precision of vancomycin AUC estimates in obese adults ( n = 75) and validate this in an independent cohort ( n = 31). The precision and mean percent bias of Bayesian vancomycin AUC estimates are comparable between covariate-dependent ( R 2 = 0.774, 3.55%) and covariate-independent ( R 2 = 0.804, 3.28%) models when peaks and troughs are measured but not when measurements are restricted to troughs only ( R 2 = 0.557, 15.5%). Copyright © 2017 American Society for Microbiology.

  11. Effect of Truncating AUC at 12, 24 and 48 hr When Evaluating the Bioequivalence of Drugs with a Long Half-Life.

    Science.gov (United States)

    Moreno, Isabel; Ochoa, Dolores; Román, Manuel; Cabaleiro, Teresa; Abad-Santos, Francisco

    2016-01-01

    Bioequivalence studies of drugs with a long half-life require long periods of time for pharmacokinetic sampling. The latest update of the European guideline allows the area under the curve (AUC) truncated at 72 hr to be used as an alternative to AUC0-t as the primary parameter. The objective of this study was to evaluate the effect of truncating the AUC at 48, 24 and 12 hr on the acceptance of the bioequivalence criterion as compared with truncation at 72 hr in bioequivalence trials. The effect of truncated AUC on the within-individual coefficient of variation (CVw) and on the ratio of the formulations was also analysed. Twenty-eight drugs were selected from bioequivalence trials. Pharmacokinetic data were analysed using WinNonLin 2.0 based on the trapezoidal method. Analysis of variance (ANOVA) was performed to obtain the ratios and 90% confidence intervals for AUC at different time-points. The degree of agreement of AUC0-72 in relation to AUC0-48 and AUC0-24, according to the Landis and Koch classification, was 'almost perfect'. Statistically significant differences were observed when the CVw of AUC truncated at 72, 48 and 24 hr was compared with the CVw of AUC0-12. There were no statistically significant differences in the AUC ratio at any time-point. Compared to AUC0-72, Pearson's correlation coefficient for mean AUC, AUC ratio and AUC CVw was worse for AUC0-12 than AUC0-24 or AUC0-48. These preliminary results could suggest that AUC truncation at 24 or 48 hr is adequate to determine whether two formulations are bioequivalent. © 2015 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).

  12. An alternative approach to calculating Area-Under-the-Curve (AUC) in delay discounting research.

    Science.gov (United States)

    Borges, Allison M; Kuang, Jinyi; Milhorn, Hannah; Yi, Richard

    2016-09-01

    Applied to delay discounting data, Area-Under-the-Curve (AUC) provides an atheoretical index of the rate of delay discounting. The conventional method of calculating AUC, by summing the areas of the trapezoids formed by successive delay-indifference point pairings, does not account for the fact that most delay discounting tasks scale delay pseudoexponentially, that is, time intervals between delays typically get larger as delays get longer. This results in a disproportionate contribution of indifference points at long delays to the total AUC, with minimal contribution from indifference points at short delays. We propose two modifications that correct for this imbalance via a base-10 logarithmic transformation and an ordinal scaling transformation of delays. These newly proposed indices of discounting, AUClog d and AUCor d, address the limitation of AUC while preserving a primary strength (remaining atheoretical). Re-examination of previously published data provides empirical support for both AUClog d and AUCor d . Thus, we believe theoretical and empirical arguments favor these methods as the preferred atheoretical indices of delay discounting. © 2016 Society for the Experimental Analysis of Behavior.

  13. Bayesian approach to estimate AUC, partition coefficient and drug targeting index for studies with serial sacrifice design.

    Science.gov (United States)

    Wang, Tianli; Baron, Kyle; Zhong, Wei; Brundage, Richard; Elmquist, William

    2014-03-01

    The current study presents a Bayesian approach to non-compartmental analysis (NCA), which provides the accurate and precise estimate of AUC 0 (∞) and any AUC 0 (∞) -based NCA parameter or derivation. In order to assess the performance of the proposed method, 1,000 simulated datasets were generated in different scenarios. A Bayesian method was used to estimate the tissue and plasma AUC 0 (∞) s and the tissue-to-plasma AUC 0 (∞) ratio. The posterior medians and the coverage of 95% credible intervals for the true parameter values were examined. The method was applied to laboratory data from a mice brain distribution study with serial sacrifice design for illustration. Bayesian NCA approach is accurate and precise in point estimation of the AUC 0 (∞) and the partition coefficient under a serial sacrifice design. It also provides a consistently good variance estimate, even considering the variability of the data and the physiological structure of the pharmacokinetic model. The application in the case study obtained a physiologically reasonable posterior distribution of AUC, with a posterior median close to the value estimated by classic Bailer-type methods. This Bayesian NCA approach for sparse data analysis provides statistical inference on the variability of AUC 0 (∞) -based parameters such as partition coefficient and drug targeting index, so that the comparison of these parameters following destructive sampling becomes statistically feasible.

  14. Accuracy, calibration and clinical performance of the EuroSCORE: can we reduce the number of variables?

    Science.gov (United States)

    Ranucci, Marco; Castelvecchio, Serenella; Menicanti, Lorenzo; Frigiola, Alessandro; Pelissero, Gabriele

    2010-03-01

    The European system for cardiac operative risk evaluation (EuroSCORE) is currently used in many institutions and is considered a reference tool in many countries. We hypothesised that too many variables were included in the EuroSCORE using limited patient series. We tested different models using a limited number of variables. A total of 11150 adult patients undergoing cardiac operations at our institution (2001-2007) were retrospectively analysed. The 17 risk factors composing the EuroSCORE were separately analysed and ranked for accuracy of prediction of hospital mortality. Seventeen models were created by progressively including one factor at a time. The models were compared for accuracy with a receiver operating characteristics (ROC) analysis and area under the curve (AUC) evaluation. Calibration was tested with Hosmer-Lemeshow statistics. Clinical performance was assessed by comparing the predicted with the observed mortality rates. The best accuracy (AUC 0.76) was obtained using a model including only age, left ventricular ejection fraction, serum creatinine, emergency operation and non-isolated coronary operation. The EuroSCORE AUC (0.75) was not significantly different. Calibration and clinical performance were better in the five-factor model than in the EuroSCORE. Only in high-risk patients were 12 factors needed to achieve a good performance. Including many factors in multivariable logistic models increases the risk for overfitting, multicollinearity and human error. A five-factor model offers the same level of accuracy but demonstrated better calibration and clinical performance. Models with a limited number of factors may work better than complex models when applied to a limited number of patients. Copyright (c) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  15. Utility of the AAOS Appropriate Use Criteria (AUC) for Pediatric Supracondylar Humerus Fractures in Clinical Practice.

    Science.gov (United States)

    Ibrahim, Talal; Hegazy, Abdelsalam; Abulhail, Safa I S; Ghomrawi, Hassan M K

    2017-01-01

    The American Academy of Orthopaedic Surgeons (AAOS) recently developed an Appropriate Use Criteria (AUC) for pediatric supracondylar humerus fractures (PSHF). The AUC is intended to improve quality of care by informing surgeon decision making. The aim of our study was to cross-reference the management of operatively treated PSHF with the AAOS-published AUC. The AUC for PSHF include 220 patient scenarios, based on different combinations of 6 factors. For each patient scenario, 8 treatment options are evaluated as "appropriate," "maybe appropriate," and "rarely appropriate." We retrospectively reviewed the medical charts and radiographs of all operatively treated PSHF at our hospital from January 2013 to December 2014 and determined the appropriateness of the treatment. Over the study period, 94 children (mean age: 5.2 y; 51 male, 43 female) were admitted with PSHF and underwent a surgical procedure (type IIA: 7, type IIB: 14, type III: 70, flexion type: 3). Only 8 of the 220 scenarios were observed in our patient cohort. The most frequent scenario was represented by a type III fracture, palpable distal pulse, no nerve injury, closed soft-tissue envelope, no radius/ulna fracture, and typical swelling. Of the 94 fractures, the AUC was "appropriate" for 84 cases and "maybe appropriate" for 9 cases. There was only 1 case of "rarely appropriate" management. Closed reduction with lateral pinning and immobilization was the most prevalent treatment option (58.5%). The rate of appropriateness was not affected by the operating surgeon. However, the definition of a case as emergent had a significant impact on the rate of appropriateness. Application of the AUC to actual clinical data was relatively simple. The majority of operatively treated PSHF (89.4%) were managed appropriately. With the introduction of electronic medical charts, an AUC application becomes attractive and easy for orthopaedic surgeons to utilize in clinical practice. However, validity studies of the AUC in

  16. Survival associated pathway identification with group Lp penalized global AUC maximization

    Directory of Open Access Journals (Sweden)

    Liu Zhenqiu

    2010-08-01

    Full Text Available Abstract It has been demonstrated that genes in a cell do not act independently. They interact with one another to complete certain biological processes or to implement certain molecular functions. How to incorporate biological pathways or functional groups into the model and identify survival associated gene pathways is still a challenging problem. In this paper, we propose a novel iterative gradient based method for survival analysis with group Lp penalized global AUC summary maximization. Unlike LASSO, Lp (p 1. We first extend Lp for individual gene identification to group Lp penalty for pathway selection, and then develop a novel iterative gradient algorithm for penalized global AUC summary maximization (IGGAUCS. This method incorporates the genetic pathways into global AUC summary maximization and identifies survival associated pathways instead of individual genes. The tuning parameters are determined using 10-fold cross validation with training data only. The prediction performance is evaluated using test data. We apply the proposed method to survival outcome analysis with gene expression profile and identify multiple pathways simultaneously. Experimental results with simulation and gene expression data demonstrate that the proposed procedures can be used for identifying important biological pathways that are related to survival phenotype and for building a parsimonious model for predicting the survival times.

  17. Accuracy of Clinical Tests in Detecting Disk Herniation and Nerve Root Compression in Subjects With Lumbar Radicular Symptoms.

    Science.gov (United States)

    Ekedahl, Harald; Jönsson, Bo; Annertz, Mårten; Frobell, Richard B

    2018-04-01

    To investigate the accuracy of 3 commonly used neurodynamic tests (slump test, straight-leg raise [SLR] test, femoral neurodynamic test) and 2 clinical assessments to determine radiculopathy (radiculopathy I, 1 neurologic sign; radiculopathy II, 2 neurologic signs corresponding to 1 specific nerve root) in detecting magnetic resonance imaging (MRI) findings (extrusion, subarticular nerve root compression, and foraminal nerve root compression). Validity study. Secondary care. We included subjects (N=99; mean age, 58y; 54% women) referred for epidural steroid injection because of lumbar radicular symptoms who had positive clinical and MRI findings. Positive clinical findings included the slump test (n=67), SLR test (n=50), femoral neurodynamic test (n=7), radiculopathy I (n=70), and radiculopathy II (n=33). Positive MRI findings included extrusion (n=27), subarticular nerve compression (n=14), and foraminal nerve compression (n=25). Not applicable. Accuracy of clinical tests in detecting MRI findings was evaluated using sensitivity, specificity, and receiver operating characteristics analysis with area under the curve (AUC). The slump test had the highest sensitivity in detecting extrusion (.78) and subarticular nerve compression (1.00), but the respective specificity was low (.36 and .38). Radiculopathy I was most sensitive in detecting foraminal nerve compression (.80) but with low specificity (.34). Only 1 assessment had a concurrent high sensitivity and specificity (ie, radiculopathy II) in detecting subarticular nerve compression (.71 and .73, respectively). The AUC for all tests in detecting extrusion, subarticular nerve compression, and foraminal nerve compression showed ranges of .48 to .60, .63 to .82, and .33 to .57, respectively. In general, the investigated neurodynamic tests or assessments for radiculopathy lacked diagnostic accuracy. The slump test was the most sensitive test, while radiculopathy II was the most specific test. Most interestingly, no

  18. Study of secular equilibrium reinstatement on UO2 pellets manufactured by AUC route

    International Nuclear Information System (INIS)

    Carnaval, João Paulo R.; Beltran, Dalton J.M.C.; Oliveira, Carlos A.

    2017-01-01

    The fuel assemblies manufactured by INB for Angra-1 power plant has axial blanket fuel rods which must be inspected due the columns formed by different enrichment pellets. The equipment used for inspection is built with a group of BGO scintillators detectors which measurement principle is based on the absorption of gamma rays emitted from Uranium decay. The commercial grade UF 6 used by INB is stored into cylinders type 30B. The uranium inside these cylinders is in secular equilibrium before the processing. It has been found that the AUC route causes the loss of that equilibrium because the UF 6 is volatilized from the cylinder and the uranium daughters remain in the container. As AUC is converted to powder and pellets, the secular equilibrium is restored through time. The purpose of this work is to present a study of the secular equilibrium reinstatement on UO 2 pellets manufactured by AUC route before being inspected on Rod Scanner. (author)

  19. Preparation and characterization of Fe3O4@Au-C225 composite targeted nanoparticles for MRI of human glioma.

    Science.gov (United States)

    Ge, Yaoqi; Zhong, Yuejiao; Ji, Guozhong; Lu, Qianling; Dai, Xinyu; Guo, Zhirui; Zhang, Peng; Peng, Gang; Zhang, Kangzhen; Li, Yuntao

    2018-01-01

    To study the characterization of Fe3O4@Au-C225 composite targeted MNPs. Fe3O4@Au-C225 was prepared by the absorption method. The immunosorbent assay was used to evaluate its absorption efficiency at C225 Fc. ZETA SIZER3000 laser particle size analyzer, ultraviolet photometer and its characteristics were analyzed by VSM. the targeting effect of Fe3O4@Au-C225 composite targeted MNPs on U251 cells in vitro were detected by 7.0 Tesla Micro-MR; and subcutaneous transplanted human glioma in nude mice were performed the targeting effect in vivo after tail vein injection of Fe3O4@Au-C225 composite targeted MNPs by MRI. The self-prepared Fe3O4@Au composite MNPs can adsorb C225 with high efficiency of adsorption so that Fe3O4@Au-C225 composite targeted MNPs were prepared successfully. Fe3O4@Au-C225 composite targeted MNPs favorably targeted human glioma cell line U251 in vitro; Fe3O4@Au-C225 composite targeted MNPs have good targeting ability to xenografted glioma on nude mice in vivo, and can be traced by MRI. The Fe3O4@Au-C225 composite targeted MNPs have the potential to be used as a tracer for glioma in vivo.

  20. Accuracy of magnetic resonance studies in the detection of chondral and labral lesions in femoroacetabular impingement: systematic review and meta-analysis.

    Science.gov (United States)

    Saied, A M; Redant, C; El-Batouty, M; El-Lakkany, M R; El-Adl, W A; Anthonissen, J; Verdonk, R; Audenaert, E A

    2017-02-16

    Several types of Magnetic resonance imaging (MRI) are commonly used in imaging of femoroacetabular impingement (FAI), however till now there are no clear protocols and recommendations for each type. The aim of this meta-analysis is to detect the accuracy of conventional magnetic resonance imaging (cMRI), direct magnetic resonance arthrography (dMRA) and indirect magnetic resonance arthrography (iMRA) in the diagnosis of chondral and labral lesions in femoroacetabular impingement (FAI). A literature search was finalized on the 17th of May 2016 to collect all studies identifying the accuracy of cMRI, dMRA and iMRA in diagnosing chondral and labral lesions associated with FAI using surgical results (arthroscopic or open) as a reference test. Pooled sensitivity and specificity with 95% confidence intervals using a random-effects meta-analysis for MRI, dMRA and iMRA were calculated also area under receiver operating characteristic (ROC) curve (AUC) was retrieved whenever possible where AUC is equivocal to diagnostic accuracy. The search yielded 192 publications which were reviewed according inclusion and exclusion criteria then 21 studies fulfilled the eligibility criteria for the qualitative analysis with a total number of 828 cases, lastly 12 studies were included in the quantitative meta-analysis. Meta-analysis showed that as regard labral lesions the pooled sensitivity, specificity and AUC for cMRI were 0.864, 0.833 and 0.88 and for dMRA were 0.91, 0.58 and 0.92. While in chondral lesions the pooled sensitivity, specificity and AUC for cMRI were 0.76, 0.72 and 0.75 and for dMRA were 0.75, 0.79 and 0.83, while for iMRA were sensitivity of 0.722 and specificity of 0.917. The present meta-analysis showed that the diagnostic test accuracy was superior for dMRA when compared with cMRI for detection of labral and chondral lesions. The diagnostic test accuracy was superior for labral lesions when compared with chondral lesions in both cMRI and dMRA. Promising results are

  1. Simple Decision-Analytic Functions of the AUC for Ruling Out a Risk Prediction Model and an Added Predictor.

    Science.gov (United States)

    Baker, Stuart G

    2018-02-01

    When using risk prediction models, an important consideration is weighing performance against the cost (monetary and harms) of ascertaining predictors. The minimum test tradeoff (MTT) for ruling out a model is the minimum number of all-predictor ascertainments per correct prediction to yield a positive overall expected utility. The MTT for ruling out an added predictor is the minimum number of added-predictor ascertainments per correct prediction to yield a positive overall expected utility. An approximation to the MTT for ruling out a model is 1/[P (H(AUC model )], where H(AUC) = AUC - {½ (1-AUC)} ½ , AUC is the area under the receiver operating characteristic (ROC) curve, and P is the probability of the predicted event in the target population. An approximation to the MTT for ruling out an added predictor is 1 /[P {(H(AUC Model:2 ) - H(AUC Model:1 )], where Model 2 includes an added predictor relative to Model 1. The latter approximation requires the Tangent Condition that the true positive rate at the point on the ROC curve with a slope of 1 is larger for Model 2 than Model 1. These approximations are suitable for back-of-the-envelope calculations. For example, in a study predicting the risk of invasive breast cancer, Model 2 adds to the predictors in Model 1 a set of 7 single nucleotide polymorphisms (SNPs). Based on the AUCs and the Tangent Condition, an MTT of 7200 was computed, which indicates that 7200 sets of SNPs are needed for every correct prediction of breast cancer to yield a positive overall expected utility. If ascertaining the SNPs costs $500, this MTT suggests that SNP ascertainment is not likely worthwhile for this risk prediction.

  2. Combined Scintigraphy and Tumor Marker Analysis Predicts Unfavorable Histopathology of Neuroblastic Tumors with High Accuracy.

    Directory of Open Access Journals (Sweden)

    Wolfgang Peter Fendler

    Full Text Available Our aim was to improve the prediction of unfavorable histopathology (UH in neuroblastic tumors through combined imaging and biochemical parameters.123I-MIBG SPECT and MRI was performed before surgical resection or biopsy in 47 consecutive pediatric patients with neuroblastic tumor. Semi-quantitative tumor-to-liver count-rate ratio (TLCRR, MRI tumor size and margins, urine catecholamine and NSE blood levels of neuron specific enolase (NSE were recorded. Accuracy of single and combined variables for prediction of UH was tested by ROC analysis with Bonferroni correction.34 of 47 patients had UH based on the International Neuroblastoma Pathology Classification (INPC. TLCRR and serum NSE both predicted UH with moderate accuracy. Optimal cut-off for TLCRR was 2.0, resulting in 68% sensitivity and 100% specificity (AUC-ROC 0.86, p < 0.001. Optimal cut-off for NSE was 25.8 ng/ml, resulting in 74% sensitivity and 85% specificity (AUC-ROC 0.81, p = 0.001. Combination of TLCRR/NSE criteria reduced false negative findings from 11/9 to only five, with improved sensitivity and specificity of 85% (AUC-ROC 0.85, p < 0.001.Strong 123I-MIBG uptake and high serum level of NSE were each predictive of UH. Combined analysis of both parameters improved the prediction of UH in patients with neuroblastic tumor. MRI parameters and urine catecholamine levels did not predict UH.

  3. Accuracy of Blood Pressure-to-Height Ratio to Define Elevated Blood Pressure in Children and Adolescents: The CASPIAN-IV Study.

    Science.gov (United States)

    Kelishadi, Roya; Bahreynian, Maryam; Heshmat, Ramin; Motlagh, Mohammad Esmail; Djalalinia, Shirin; Naji, Fatemeh; Ardalan, Gelayol; Asayesh, Hamid; Qorbani, Mostafa

    2016-02-01

    The aim of this study was to propose a simple practical diagnostic criterion for pre-hypertension (pre-HTN) and hypertension (HTN) in the pediatric age group. This study was conducted on a nationally representative sample of 14,880 students, aged 6-18 years. HTN and pre-HTN were defined as systolic blood pressure (SBP) and/or diastolic blood pressure (DBP) ≥ 95 and 90-95th percentile for age, gender, and height, respectively. By using the area under the curve (AUC) of the receiver operator characteristic curves, we estimated the diagnostic accuracy of two indexes of SBP-to-height ratio (SBPHR) and DBP-to-height (DBPHR) to define pre-HTN and HTN. Overall, SBPHR performed relatively well in classifying subjects to HTN (AUC 0.80-0.85) and pre-HTN (AUC 0.84-0.90). Likewise, DBPHR performed relatively well in classifying subjects to HTN (AUC 0.90-0.97) and pre-HTN (AUC 0.70-0.83). Two indexes of SBPHR and DBPHR are considered as valid, simple, inexpensive, and accurate tools to diagnose pre-HTN and HTN in pediatric age group.

  4. Comparison of 3 estimation methods of mycophenolic acid AUC based on a limited sampling strategy in renal transplant patients.

    Science.gov (United States)

    Hulin, Anne; Blanchet, Benoît; Audard, Vincent; Barau, Caroline; Furlan, Valérie; Durrbach, Antoine; Taïeb, Fabrice; Lang, Philippe; Grimbert, Philippe; Tod, Michel

    2009-04-01

    A significant relationship between mycophenolic acid (MPA) area under the plasma concentration-time curve (AUC) and the risk for rejection has been reported. Based on 3 concentration measurements, 3 approaches have been proposed for the estimation of MPA AUC, involving either a multilinear regression approach model (MLRA) or a Bayesian estimation using either gamma absorption or zero-order absorption population models. The aim of the study was to compare the 3 approaches for the estimation of MPA AUC in 150 renal transplant patients treated with mycophenolate mofetil and tacrolimus. The population parameters were determined in 77 patients (learning study). The AUC estimation methods were compared in the learning population and in 73 patients from another center (validation study). In the latter study, the reference AUCs were estimated by the trapezoidal rule on 8 measurements. MPA concentrations were measured by liquid chromatography. The gamma absorption model gave the best fit. In the learning study, the AUCs estimated by both Bayesian methods were very similar, whereas the multilinear approach was highly correlated but yielded estimates about 20% lower than Bayesian methods. This resulted in dosing recommendations differing by 250 mg/12 h or more in 27% of cases. In the validation study, AUC estimates based on the Bayesian method with gamma absorption model and multilinear regression approach model were, respectively, 12% higher and 7% lower than the reference values. To conclude, the bicompartmental model with gamma absorption rate gave the best fit. The 3 AUC estimation methods are highly correlated but not concordant. For a given patient, the same estimation method should always be used.

  5. Limited sampling strategy models for estimating the AUC of gliclazide in Chinese healthy volunteers.

    Science.gov (United States)

    Huang, Ji-Han; Wang, Kun; Huang, Xiao-Hui; He, Ying-Chun; Li, Lu-Jin; Sheng, Yu-Cheng; Yang, Juan; Zheng, Qing-Shan

    2013-06-01

    The aim of this work is to reduce the cost of required sampling for the estimation of the area under the gliclazide plasma concentration versus time curve within 60 h (AUC0-60t ). The limited sampling strategy (LSS) models were established and validated by the multiple regression model within 4 or fewer gliclazide concentration values. Absolute prediction error (APE), root of mean square error (RMSE) and visual prediction check were used as criterion. The results of Jack-Knife validation showed that 10 (25.0 %) of the 40 LSS based on the regression analysis were not within an APE of 15 % using one concentration-time point. 90.2, 91.5 and 92.4 % of the 40 LSS models were capable of prediction using 2, 3 and 4 points, respectively. Limited sampling strategies were developed and validated for estimating AUC0-60t of gliclazide. This study indicates that the implementation of an 80 mg dosage regimen enabled accurate predictions of AUC0-60t by the LSS model. This study shows that 12, 6, 4, 2 h after administration are the key sampling times. The combination of (12, 2 h), (12, 8, 2 h) or (12, 8, 4, 2 h) can be chosen as sampling hours for predicting AUC0-60t in practical application according to requirement.

  6. Study of secular equilibrium reinstatement on UO{sub 2} pellets manufactured by AUC route

    Energy Technology Data Exchange (ETDEWEB)

    Carnaval, João Paulo R.; Beltran, Dalton J.M.C.; Oliveira, Carlos A., E-mail: joaocarnaval@inb.gov.br, E-mail: daltonbeltran@inb.gov.br, E-mail: carlossilva@inb.gov.br [Indústrias Nucleares do Brasil S.A. (INB), Resende, RJ (Brazil)

    2017-07-01

    The fuel assemblies manufactured by INB for Angra-1 power plant has axial blanket fuel rods which must be inspected due the columns formed by different enrichment pellets. The equipment used for inspection is built with a group of BGO scintillators detectors which measurement principle is based on the absorption of gamma rays emitted from Uranium decay. The commercial grade UF{sub 6} used by INB is stored into cylinders type 30B. The uranium inside these cylinders is in secular equilibrium before the processing. It has been found that the AUC route causes the loss of that equilibrium because the UF{sub 6} is volatilized from the cylinder and the uranium daughters remain in the container. As AUC is converted to powder and pellets, the secular equilibrium is restored through time. The purpose of this work is to present a study of the secular equilibrium reinstatement on UO{sub 2} pellets manufactured by AUC route before being inspected on Rod Scanner. (author)

  7. Dried blood spot measurement: application in tacrolimus monitoring using limited sampling strategy and abbreviated AUC estimation.

    Science.gov (United States)

    Cheung, Chi Yuen; van der Heijden, Jaques; Hoogtanders, Karin; Christiaans, Maarten; Liu, Yan Lun; Chan, Yiu Han; Choi, Koon Shing; van de Plas, Afke; Shek, Chi Chung; Chau, Ka Foon; Li, Chun Sang; van Hooff, Johannes; Stolk, Leo

    2008-02-01

    Dried blood spot (DBS) sampling and high-performance liquid chromatography tandem-mass spectrometry have been developed in monitoring tacrolimus levels. Our center favors the use of limited sampling strategy and abbreviated formula to estimate the area under concentration-time curve (AUC(0-12)). However, it is inconvenient for patients because they have to wait in the center for blood sampling. We investigated the application of DBS method in tacrolimus level monitoring using limited sampling strategy and abbreviated AUC estimation approach. Duplicate venous samples were obtained at each time point (C(0), C(2), and C(4)). To determine the stability of blood samples, one venous sample was sent to our laboratory immediately. The other duplicate venous samples, together with simultaneous fingerprick blood samples, were sent to the University of Maastricht in the Netherlands. Thirty six patients were recruited and 108 sets of blood samples were collected. There was a highly significant relationship between AUC(0-12), estimated from venous blood samples, and fingerprick blood samples (r(2) = 0.96, P AUC(0-12) strategy as drug monitoring.

  8. [Accuracy of three methods for the rapid diagnosis of oral candidiasis].

    Science.gov (United States)

    Lyu, X; Zhao, C; Yan, Z M; Hua, H

    2016-10-09

    Objective: To explore a simple, rapid and efficient method for the diagnosis of oral candidiasis in clinical practice. Methods: Totally 124 consecutive patients with suspected oral candidiasis were enrolled from Department of Oral Medicine, Peking University School and Hospital of Stomatology, Beijing, China. Exfoliated cells of oral mucosa and saliva or concentrated oral rinse) obtained from all participants were tested by three rapid smear methods(10% KOH smear, gram-stained smear, Congo red stained smear). The diagnostic efficacy(sensitivity, specificity, Youden's index, likelihood ratio, consistency, predictive value and area under curve(AUC) of each of the above mentioned three methods was assessed by comparing the results with the gold standard(combination of clinical diagnosis, laboratory diagnosis and expert opinion). Results: Gram-stained smear of saliva(or concentrated oral rinse) demonstrated highest sensitivity(82.3%). Test of 10%KOH smear of exfoliated cells showed highest specificity(93.5%). Congo red stained smear of saliva(or concentrated oral rinse) displayed highest diagnostic efficacy(79.0% sensitivity, 80.6% specificity, 0.60 Youden's index, 4.08 positive likelihood ratio, 0.26 negative likelihood ratio, 80% consistency, 80.3% positive predictive value, 79.4% negative predictive value and 0.80 AUC). Conclusions: Test of Congo red stained smear of saliva(or concentrated oral rinse) could be used as a point-of-care tool for the rapid diagnosis of oral candidiasis in clinical practice. Trial registration: Chinese Clinical Trial Registry, ChiCTR-DDD-16008118.

  9. Relationship between the clinical efficacy and AUC/MIC of intravenous ciprofloxacin in Japanese patients with intraabdominal infections.

    Science.gov (United States)

    Ohki, Emiko; Yamagishi, Yuka; Mikamo, Hiroshige

    2013-10-01

    The efficacy of fluoroquinolones (FQs) correlates with the pharmacokinetic/pharmacodynamic (PK-PD) parameter, AUC/MIC. To our knowledge, however, no prospective studies have reported the relationship between FQ efficacy and PK-PD parameters in intraabdominal infection; therefore, we prospectively investigated the relationship between the efficacy of intravenous ciprofloxacin (CPFX IV) and PK-PD parameters. The study included 16 patients diagnosed with peritonitis between 2006 and 2008: 14 patients infected with a single organism and 2 patients infected with more than one organism. Each patient was treated with CPFX IV (300 mg twice daily). The response rate was 56% (9 responders and 7 non-responders). Non-responders were infected with Escherichia coli, Pseudomonas aeruginosa, and Bacteroides fragilis (6 patients were infected with a single organism and 1 with more than one organism). Plasma drug concentrations were measured 1 h and 2 or 4 h after administration of CPFX IV. AUC for 24 h (AUC(0-24))/MIC values was calculated. The range of AUC(0-24)/MIC values in responders [95.3-3628.4 (geometric mean, 521.6)] was significantly different from that in non-responders [7.0-45.2 (geometric mean, 16.5)] (p = 0.001). The target AUC/MIC value of CPFX IV would be considered to be 45-95 in patients with peritonitis.

  10. Accuracy of ultra-wide-field fundus ophthalmoscopy-assisted deep learning, a machine-learning technology, for detecting age-related macular degeneration.

    Science.gov (United States)

    Matsuba, Shinji; Tabuchi, Hitoshi; Ohsugi, Hideharu; Enno, Hiroki; Ishitobi, Naofumi; Masumoto, Hiroki; Kiuchi, Yoshiaki

    2018-05-09

    To predict exudative age-related macular degeneration (AMD), we combined a deep convolutional neural network (DCNN), a machine-learning algorithm, with Optos, an ultra-wide-field fundus imaging system. First, to evaluate the diagnostic accuracy of DCNN, 364 photographic images (AMD: 137) were amplified and the area under the curve (AUC), sensitivity and specificity were examined. Furthermore, in order to compare the diagnostic abilities between DCNN and six ophthalmologists, we prepared yield 84 sheets comprising 50% of normal and wet-AMD data each, and calculated the correct answer rate, specificity, sensitivity, and response times. DCNN exhibited 100% sensitivity and 97.31% specificity for wet-AMD images, with an average AUC of 99.76%. Moreover, comparing the diagnostic abilities of DCNN versus six ophthalmologists, the average accuracy of the DCNN was 100%. On the other hand, the accuracy of ophthalmologists, determined only by Optos images without a fundus examination, was 81.9%. A combination of DCNN with Optos images is not better than a medical examination; however, it can identify exudative AMD with a high level of accuracy. Our system is considered useful for screening and telemedicine.

  11. Sintering of uranium dioxide obtained by continuous precipitation of AUC

    International Nuclear Information System (INIS)

    Amaya, C.D.; Sterba, M.E.; Russo, D.O.

    1993-01-01

    The Nuclear Materials Division in Bariloche Atomic Center evaluates the ceramic behaviour of UO 2 powders obtained from continuously precipitated and reduced AUC (Ammonium Uranyl Tri Carbonate). An analysis is made of powder characteristics (particle morphology and size distribution and specific area) on behaviour of UO 2 during sintering (compaction, sintering, pore and grain microstructure, etc.). 1 ref

  12. Traffic days '95 at AUC. Conference report. Vol. 1

    International Nuclear Information System (INIS)

    Lohmann-Hansen, A.

    1995-01-01

    Volume one of Traffic days '95 at AUC (Aalborg University, Denmark) contains 28 papers presented at the conference held on August 21 - 22, 1995, at Aalborg University in Jutland, Denmark. The papers in this volume are ranged under the general headings of: The road to sustainable transport, the evaluation of traffic and infrastructure planning - decision-making procedures, traffic and the environment in towns, railways, traffic information + signals, and environmental conditions relative to shipping

  13. The ciprofloxacin target AUC : MIC ratio is not reached in hospitalized patients with the recommended dosing regimens.

    Science.gov (United States)

    Haeseker, Michiel; Stolk, Leo; Nieman, Fred; Hoebe, Christian; Neef, Cees; Bruggeman, Cathrien; Verbon, Annelies

    2013-01-01

    The aim of this study was to determine the ciprofloxacin serum concentrations in hospitalized patients and to determine which percentage reached the efficacy target of AUC : MIC > 125. Additionally, the influence of demographic anthropomorphic and clinical parameters on the pharmacokinetics and pharmacodynamics of ciprofloxacin were investigated. In serum of 80 hospitalized patients ciprofloxacin concentrations were measured with reverse phase high performance liquid chromatography with fluorescence detection. The ciprofloxacin dose was 400-1200 mg day(-1) i.v. in two or three doses depending on renal function and causative bacteria. Pharmacokinetic parameters were calculated with maximum a posteriori Bayesian estimation (MW\\PHARM 3.60). A two compartment open model was used. Mean (± SD) age was 66 (± 17) years, the mean clearance corrected for bodyweight was 0.24 l h(-1) kg(-1) and the mean AUC was 49 mg l(-1) h. Ciprofloxacin clearance and thus AUC were associated with both age and serum creatinine. Of all patients, 21% and 75% of the patients, did not reach the proposed ciprofloxacin AUC : MIC > 125 target with MICs of 0.25 and 0.5 mg l(-1), respectively. A computer simulated increase in the daily dose from 800 mg to 1200 mg, decreased these percentages to 1% and 37%, respectively. A substantial proportion of the hospitalized patients did not reach the target ciprofloxacin AUC : MIC and are suboptimally dosed with recommended doses. Taking into account the increasing resistance to ciprofloxacin worldwide, a ciprofloxacin dose of 1200 mg i.v. daily in patients with normal renal function is necessary to reach the targeted AUC : MIC > 125. © 2012 The Authors. British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  14. Acute imaging does not improve ASTRAL score's accuracy despite having a prognostic value.

    Science.gov (United States)

    Ntaios, George; Papavasileiou, Vasileios; Faouzi, Mohamed; Vanacker, Peter; Wintermark, Max; Michel, Patrik

    2014-10-01

    The ASTRAL score was recently shown to reliably predict three-month functional outcome in patients with acute ischemic stroke. The study aims to investigate whether information from multimodal imaging increases ASTRAL score's accuracy. All patients registered in the ASTRAL registry until March 2011 were included. In multivariate logistic-regression analyses, we added covariates derived from parenchymal, vascular, and perfusion imaging to the 6-parameter model of the ASTRAL score. If a specific imaging covariate remained an independent predictor of three-month modified Rankin score>2, the area-under-the-curve (AUC) of this new model was calculated and compared with ASTRAL score's AUC. We also performed similar logistic regression analyses in arbitrarily chosen patient subgroups. When added to the ASTRAL score, the following covariates on admission computed tomography/magnetic resonance imaging-based multimodal imaging were not significant predictors of outcome: any stroke-related acute lesion, any nonstroke-related lesions, chronic/subacute stroke, leukoaraiosis, significant arterial pathology in ischemic territory on computed tomography angiography/magnetic resonance angiography/Doppler, significant intracranial arterial pathology in ischemic territory, and focal hypoperfusion on perfusion-computed tomography. The Alberta Stroke Program Early CT score on plain imaging and any significant extracranial arterial pathology on computed tomography angiography/magnetic resonance angiography/Doppler were independent predictors of outcome (odds ratio: 0·93, 95% CI: 0·87-0·99 and odds ratio: 1·49, 95% CI: 1·08-2·05, respectively) but did not increase ASTRAL score's AUC (0·849 vs. 0·850, and 0·8563 vs. 0·8564, respectively). In exploratory analyses in subgroups of different prognosis, age or stroke severity, no covariate was found to increase ASTRAL score's AUC, either. The addition of information derived from multimodal imaging does not increase ASTRAL score

  15. Max-AUC feature selection in computer-aided detection of polyps in CT colonography.

    Science.gov (United States)

    Xu, Jian-Wu; Suzuki, Kenji

    2014-03-01

    We propose a feature selection method based on a sequential forward floating selection (SFFS) procedure to improve the performance of a classifier in computerized detection of polyps in CT colonography (CTC). The feature selection method is coupled with a nonlinear support vector machine (SVM) classifier. Unlike the conventional linear method based on Wilks' lambda, the proposed method selected the most relevant features that would maximize the area under the receiver operating characteristic curve (AUC), which directly maximizes classification performance, evaluated based on AUC value, in the computer-aided detection (CADe) scheme. We presented two variants of the proposed method with different stopping criteria used in the SFFS procedure. The first variant searched all feature combinations allowed in the SFFS procedure and selected the subsets that maximize the AUC values. The second variant performed a statistical test at each step during the SFFS procedure, and it was terminated if the increase in the AUC value was not statistically significant. The advantage of the second variant is its lower computational cost. To test the performance of the proposed method, we compared it against the popular stepwise feature selection method based on Wilks' lambda for a colonic-polyp database (25 polyps and 2624 nonpolyps). We extracted 75 morphologic, gray-level-based, and texture features from the segmented lesion candidate regions. The two variants of the proposed feature selection method chose 29 and 7 features, respectively. Two SVM classifiers trained with these selected features yielded a 96% by-polyp sensitivity at false-positive (FP) rates of 4.1 and 6.5 per patient, respectively. Experiments showed a significant improvement in the performance of the classifier with the proposed feature selection method over that with the popular stepwise feature selection based on Wilks' lambda that yielded 18.0 FPs per patient at the same sensitivity level.

  16. Discrepancy in Vancomycin AUC/MIC Ratio Targeted Attainment Based upon the Susceptibility Testing in Staphylococcus aureus.

    Science.gov (United States)

    Eum, Seenae; Bergsbaken, Robert L; Harvey, Craig L; Warren, J Bryan; Rotschafer, John C

    2016-09-27

    This study demonstrated a statistically significant difference in vancomycin minimum inhibitory concentration (MIC) for Staphylococcus aureus between a common automated system (Vitek 2) and the E-test method in patients with S. aureus bloodstream infections. At an area under the serum concentration time curve (AUC) threshold of 400 mg∙h/L, we would have reached the current Infectious Diseases Society of America (IDSA)/American Society of Health System Pharmacists (ASHP)/Society of Infectious Diseases Pharmacists (SIDP) guideline suggested AUC/MIC target in almost 100% of patients while using the Vitek 2 MIC data; however, we could only generate 40% target attainment while using E-test MIC data ( p AUC of 450 mg∙h/L or greater was required to achieve 100% target attainment using either Vitek 2 or E-test MIC results.

  17. The Goodness of Covariance Selection Problem from AUC Bounds

    OpenAIRE

    Khajavi, Navid Tafaghodi; Kuh, Anthony

    2016-01-01

    We conduct a study of graphical models and discuss the quality of model selection approximation by formulating the problem as a detection problem and examining the area under the curve (AUC). We are specifically looking at the model selection problem for jointly Gaussian random vectors. For Gaussian random vectors, this problem simplifies to the covariance selection problem which is widely discussed in literature by Dempster [1]. In this paper, we give the definition for the correlation appro...

  18. Determination of parameters dissolution of yellow-cake. Production of uranyl nitrate - Gas precipitation of AUC

    International Nuclear Information System (INIS)

    Mellah, A.

    1987-07-01

    The different stages of the purification cycle of yellow-cakes have been studied thoroughly in order to obtain an ammonium uranyl carbonate (AUC) as an intermediate product of uranium dioxide (UO 2 ). The optimal parameters of yellow-cake dissolution, filtration, extraction by solvent, scrubbing and stripping were determined. An original program of thermodynamic calculation was developed for the determination of the free energies of yellow-cake dissolution reactions. Different numerical methods were used to determine the kinetic constant, the reaction order and correlation equations of uranyl nitrate density as a function of U and H + concentrations, before and after the extraction cycle. For the first time, Algerian filteraids were used for the filtration of uranyl nitrate solutions with satisfactory results. A laboratory designed installation enabled the precipitation of AUC by injection of ammonia and carbon dioxide gases. Interesting results have been obtained and further investigations should be carried out in order to optimize all the paremeters of the gas precipitation of AUC

  19. Diagnostic accuracy of semi-automatic quantitative metrics as an alternative to expert reading of CT myocardial perfusion in the CORE320 study.

    Science.gov (United States)

    Ostovaneh, Mohammad R; Vavere, Andrea L; Mehra, Vishal C; Kofoed, Klaus F; Matheson, Matthew B; Arbab-Zadeh, Armin; Fujisawa, Yasuko; Schuijf, Joanne D; Rochitte, Carlos E; Scholte, Arthur J; Kitagawa, Kakuya; Dewey, Marc; Cox, Christopher; DiCarli, Marcelo F; George, Richard T; Lima, Joao A C

    2018-04-03

    To determine the diagnostic accuracy of semi-automatic quantitative metrics compared to expert reading for interpretation of computed tomography perfusion (CTP) imaging. The CORE320 multicenter diagnostic accuracy clinical study enrolled patients between 45 and 85 years of age who were clinically referred for invasive coronary angiography (ICA). Computed tomography angiography (CTA), CTP, single photon emission computed tomography (SPECT), and ICA images were interpreted manually in blinded core laboratories by two experienced readers. Additionally, eight quantitative CTP metrics as continuous values were computed semi-automatically from myocardial and blood attenuation and were combined using logistic regression to derive a final quantitative CTP metric score. For the reference standard, hemodynamically significant coronary artery disease (CAD) was defined as a quantitative ICA stenosis of 50% or greater and a corresponding perfusion defect by SPECT. Diagnostic accuracy was determined by area under the receiver operating characteristic curve (AUC). Of the total 377 included patients, 66% were male, median age was 62 (IQR: 56, 68) years, and 27% had prior myocardial infarction. In patient based analysis, the AUC (95% CI) for combined CTA-CTP expert reading and combined CTA-CTP semi-automatic quantitative metrics was 0.87(0.84-0.91) and 0.86 (0.83-0.9), respectively. In vessel based analyses the AUC's were 0.85 (0.82-0.88) and 0.84 (0.81-0.87), respectively. No significant difference in AUC was found between combined CTA-CTP expert reading and CTA-CTP semi-automatic quantitative metrics in patient based or vessel based analyses(p > 0.05 for all). Combined CTA-CTP semi-automatic quantitative metrics is as accurate as CTA-CTP expert reading to detect hemodynamically significant CAD. Copyright © 2018 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  20. Accuracy of peripheral arterial tonometry in the diagnosis of obstructive sleep apnea

    Directory of Open Access Journals (Sweden)

    José Antonio Pinto

    2015-10-01

    Full Text Available ABSTRACT INTRODUCTION: The use of handheld devices that assess peripheral arterial tonometry has emerged as an auxiliary method for assessment and diagnosis of obstructive sleep apnea syndrome. OBJECTIVE: To evaluate the accuracy of peripheral arterial tonometry in the diagnosis of obstructive sleep apnea. METHODS: Contemporary cohort cross-sectional study. Thirty patients with suspected obstructive sleep apnea underwent peripheral arterial tonometry and assisted nocturnal polysomnography concomitantly. RESULTS: The mean apnea/hypopnea index by peripheral arterial tonometry was significantly higher than that by polysomnography (p < 0.001, but the values of both sleep studies were significantly correlated (r = 0.762. There was a high correlation between variables: minimum oxygen saturation (r = 0.842,p < 0.001, oxygen saturation < 90% (r = 0.799, p < 0.001, and mean heart rate (r = 0.951, p < 0.001. Sensitivity and specificity were 60% and 96.2% (AUC: 0.727;p = 0.113, respectively, when at a threshold value of 5 events/h. In severe cases (≥30 events/h, the result was a sensitivity of 77.8% and a specificity of 86.4% (AUC: 0.846, p = 0.003. CONCLUSION: Peripheral arterial tonometry is a useful portable device for the diagnosis of obstructive sleep apnea; its accuracy is higher in moderate and severe cases.

  1. [Successful cyclosporine treatment in 2 patients with refractory CIDP, involving monitoring of both AUC(0-4h) and trough levels].

    Science.gov (United States)

    Takeuchi, Akiko; Shirai, Shinichi; Horiuchi, Kazuhiro; Takahashi, Ikuko; Matsushima, Masaaki; Hirotani, Makoto; Kano, Takahiro; Yabe, Ichiro; Matumoto, Akihisa; Sasaki, Hidenao

    2012-01-01

    Cyclosporine A (CYA) treatment has been reported to be probably useful for patients with chronic inflammatory demyelinating polyradiculoneuropathy (CIDP) that is resistant to conventional treatment. Although several studies have shown that appropriate area under the concentration-time curve (AUC) monitoring of CYA levels results in improved outcomes for refractory nephrotic syndrome patients, the importance of using AUC analysis for CIDP remains unclear. In this study, we measured both trough and AUC from 0 to 4 h (AUC(0-4 h)) levels of CYA in 2 patients with CIDP and compared the findings for the clinical parameters. On the basis of the CYA dosing recommendations for patients with nephrotic syndrome, we used a CYA concentration of 150 ng/ml for the trough level and an AUC(0-4 h) value of 2,500 ng/(ml·h). Patient 1 showed a significant increase in grip strength and a prolonged remission period. Patient 2 showed improvement in the modified Rankin scale and manual muscle test (MMT) scores. Monitoring both AUC(0-4 h) and trough levels of CYA seems to be a better option than monitoring the trough level alone because it leads to improved estimation of the efficacy and safety of CYA treatment in the case of CIDP patients.

  2. How to interpret a small increase in AUC with an additional risk prediction marker: decision analysis comes through

    NARCIS (Netherlands)

    Baker, Stuart G.; Schuit, Ewoud; Steyerberg, Ewout W.; Pencina, Michael J.; Vickers, Andrew; Vickers, Andew; Moons, Karel G. M.; Mol, Ben W. J.; Lindeman, Karen S.

    2014-01-01

    An important question in the evaluation of an additional risk prediction marker is how to interpret a small increase in the area under the receiver operating characteristic curve (AUC). Many researchers believe that a change in AUC is a poor metric because it increases only slightly with the

  3. An effect of re-extraction crystallization parameters on physical and chemical properties of AUC

    International Nuclear Information System (INIS)

    Yahi, Boussad

    1990-07-01

    This study is concerned with direct cristallization of ammonium uranyl carbonate (AUC) from a uranium loaded organic phase (30% TBP in kerosene), with ammonium carbonate (NH4)2 CO3. The effects of operating conditions (NH4)2 CO3 concentration, flowration residence time, temperature on the physical properties of AUC crystals (particle size distribution, specific area, density..) are reported. All products were identified (both by chemical analysis, X-Ray diffraction) as being ammonium uranyl ratio and (NH4)2 CO3 concentration favor the formation of fine AUC grains and aggregates. This is due mainly to the high concentration of (NH4)+ in the system which leads to a high solution supersaturation and consequently to a rapid formation rate of crystal (germination). The reverse phenomenon is observed at low phase ratio and (NH4)2 CO3 concentration, where germination and crystal growth ara slow and the product is mainly monocrystal. In the intermediate range, a mixture of polycrystal and aggregates is obtained. Residence time and temperature are also shown to have an effect on the processes (the effect of time being more important than temperature)

  4. What is the evidence status of Appropriate Use Criteria (AUC)? Insight from a matching exercise with the guidelines for echocardiography.

    Science.gov (United States)

    Fonseca, R; Negishi, K; Marwick, T H

    2015-08-01

    There is interest in adapting the American Appropriate Use Criteria (AUC) for transthoracic echocardiography to Australian practice. We matched 90 of 98 AUC with the guidelines (53 appropriate, 12 sometimes appropriate, 25 rarely appropriate), but eight lacked any match. Among the matched criteria, 76 (82%) indications were concordant with the guidelines. A stronger evidence base would be desirable to settle these discrepancies before Australian adoption of AUC. © 2015 Royal Australasian College of Physicians.

  5. Nitrofurantoin safety and effectiveness in treating acute uncomplicated cystitis (AUC) in hospitalized adults with renal insufficiency: antibiotic stewardship implications.

    Science.gov (United States)

    Cunha, B A; Cunha, C B; Lam, B; Giuga, J; Chin, J; Zafonte, V F; Gerson, S

    2017-07-01

    Nitrofurantoin remains a key oral antibiotic stewardship program (ASP) option in the treatment of acute uncomplicated cystitis (AUC) due to multi-drug resistant (MDR) Gram negative bacilli (GNB). However, there have been concerns regarding decreased nitrofurantoin efficacy with renal insufficiency. In our experience over the past three decades, nitrofurantoin has been safe and effective in treating AUC in hospitalized adults with renal insufficiency. Accordingly, we retrospectively reviewed our recent experience treating AUC in hospitalized adults with decreased renal function (CrCl AUC due to MDR GNB uropathogens, these results have important ASP implications. Currently, nitfurantoin is not recommended if CrCl < 60 ml/min. In our experience, used appropriately against susceptible uropathogens, nitrofurantoin was highly effective in nearly all patients with CrCl = 30-60 ml/min., and only failed in two patients due to renal insufficiency (CrCl < 30 ml/ml).

  6. Recommended aerobic fitness level for metabolic health in children and adolescents: a study of diagnostic accuracy

    DEFF Research Database (Denmark)

    Adegboye, Amanda Ra; Anderssen, Sigmund A; Froberg, Karsten

    2011-01-01

    Objective To define the optimal cut-off for low aerobic fitness and to evaluate its accuracy to predict clustering of risk factors for cardiovascular disease in children and adolescents. Design Study of diagnostic accuracy using a cross-sectional database. Setting European Youth Heart Study...... would be expected by chance (AUC >0.5) for all cut-offs. Conclusions Aerobic fitness is easy to measure, and is an accurate tool for screening children with clustering of cardiovascular risk factors. Promoting physical activity in children with aerobic fitness level lower than the suggested cut...

  7. Classification Accuracy of a Wearable Activity Tracker for Assessing Sedentary Behavior and Physical Activity in 3–5-Year-Old Children

    Directory of Open Access Journals (Sweden)

    Wonwoo Byun

    2018-03-01

    Full Text Available This study examined the accuracy of the Fitbit activity tracker (FF for quantifying sedentary behavior (SB and varying intensities of physical activity (PA in 3–5-year-old children. Twenty-eight healthy preschool-aged children (Girls: 46%, Mean age: 4.8 ± 1.0 years wore the FF and were directly observed while performing a set of various unstructured and structured free-living activities from sedentary to vigorous intensity. The classification accuracy of the FF for measuring SB, light PA (LPA, moderate-to-vigorous PA (MVPA, and total PA (TPA was examined calculating Pearson correlation coefficients (r, mean absolute percent error (MAPE, Cohen’s kappa (k, sensitivity (Se, specificity (Sp, and area under the receiver operating curve (ROC-AUC. The classification accuracies of the FF (ROC-AUC were 0.92, 0.63, 0.77 and 0.92 for SB, LPA, MVPA and TPA, respectively. Similarly, values of kappa, Se, Sp and percentage of correct classification were consistently high for SB and TPA, but low for LPA and MVPA. The FF demonstrated excellent classification accuracy for assessing SB and TPA, but lower accuracy for classifying LPA and MVPA. Our findings suggest that the FF should be considered as a valid instrument for assessing time spent sedentary and overall physical activity in preschool-aged children.

  8. Mathematical modeling of antibody drug conjugates with the target and tubulin dynamics to predict AUC.

    Science.gov (United States)

    Byun, Jong Hyuk; Jung, Il Hyo

    2018-04-14

    Antibody drug conjugates (ADCs)are one of the most recently developed chemotherapeutics to treat some types of tumor cells. They consist of monoclonal antibodies (mAbs), linkers, and potent cytotoxic drugs. Unlike common chemotherapies, ADCs combine selectively with a target at the surface of the tumor cell, and a potent cytotoxic drug (payload) effectively prevents microtubule polymerization. In this work, we construct an ADC model that considers both the target of antibodies and the receptor (tubulin) of the cytotoxic payloads. The model is simulated with brentuximab vedotin, one of ADCs, and used to investigate the pharmacokinetic (PK) characteristics of ADCs in vivo. It also predicts area under the curve (AUC) of ADCs and the payloads by identifying the half-life. The results show that dynamical behaviors fairly coincide with the observed data and half-life and capture AUC. Thus, the model can be used for estimating some parameters, fitting experimental observations, predicting AUC, and exploring various dynamical behaviors of the target and the receptor. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. New graphic AUC-based method to estimate overall survival benefit: pomalidomide reanalysis.

    Science.gov (United States)

    Fenix-Caballero, S; Diaz-Navarro, J; Prieto-Callejero, B; Rios-Sanchez, E; Alegre-del Rey, E J; Borrero-Rubio, J M

    2016-02-01

    Difference in median survival is an erratic measure and sometimes does not provide a good assessment of survival benefit. The aim of this study was to reanalyse the overall survival benefit of pomalidomide from pivotal clinical trial using a new area under curve (AUC)-based method. In the pivotal trial, pomalidomide plus low-dose dexamethasone showed a significant survival benefit over high-dose dexamethasone, with a difference between medians of 4.6 months. The new AUC method applied to the survival curves, obtained an overall survival benefit of 2.6 months for the pomalidomide treatment. This average difference in OS was calculated for the 61.5% of patients for whom the time to event is reliable enough. This 2-month differential would have major clinical and pharmacoeconomic implications, on both cost-effectiveness studies and on the willingness of the healthcare systems to pay for this treatment. © 2015 John Wiley & Sons Ltd.

  10. Accuracy of peripheral arterial tonometry in the diagnosis of obstructive sleep apnea.

    Science.gov (United States)

    Pinto, José Antonio; Godoy, Luciana Balester Mello de; Ribeiro, Renata Coutinho; Mizoguchi, Elcio Izumi; Hirsch, Lina Ana Medeiros; Gomes, Leonardo Marques

    2015-01-01

    The use of handheld devices that assess peripheral arterial tonometry has emerged as an auxiliary method for assessment and diagnosis of obstructive sleep apnea syndrome. To evaluate the accuracy of peripheral arterial tonometry in the diagnosis of obstructive sleep apnea. Contemporary cohort cross-sectional study. Thirty patients with suspected obstructive sleep apnea underwent peripheral arterial tonometry and assisted nocturnal polysomnography concomitantly. The mean apnea/hypopnea index by peripheral arterial tonometry was significantly higher than that by polysomnography (p<0.001), but the values of both sleep studies were significantly correlated (r=0.762). There was a high correlation between variables: minimum oxygen saturation (r=0.842, p<0.001), oxygen saturation<90% (r=0.799, p<0.001), and mean heart rate (r=0.951, p<0.001). Sensitivity and specificity were 60% and 96.2% (AUC: 0.727; p=0.113), respectively, when at a threshold value of 5 events/h. In severe cases (≥30 events/h), the result was a sensitivity of 77.8% and a specificity of 86.4% (AUC: 0.846, p=0.003). Peripheral arterial tonometry is a useful portable device for the diagnosis of obstructive sleep apnea; its accuracy is higher in moderate and severe cases. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  11. Long-term follow-up and salvage surgery in patients with T2N0M0 squamous cell carcinoma of the glottic larynx who received concurrent chemoradiation therapy with carboplatin (CBDCA) - AUC 1.5 vs AUC 2.0.

    Science.gov (United States)

    Furusaka, Tohru; Matsuda, Hiroshi; Saito, Tsutomu; Katsura, Yoshihisa; Ikeda, Minoru

    2012-11-01

    Patients who received concurrent chemoradiation therapy with carboplatin were followed up on a long-term basis. In 25 patients treated with carboplatin at an AUC of 2.0 mg/ml, the complete response (CR), 10-year survival, and 10-year larynx preservation rates were 96.0%, 91.1%, and 75.2%, respectively, and the safety margin for partial laryngectomy was 4 mm from the gross tumor. To perform long-term follow-up of the therapeutic outcomes of concurrent chemoradiation therapy and salvage surgery to determine the additive and synergistic effects of anticancer drugs combined with chemoradiotherapy. Fifty male patients (aged 33-76 years) with untreated T2N0M0 squamous cell carcinoma of the glottic larynx were included. Carboplatin was intravenously administered once a week for 4 weeks. Radiotherapy was delivered by an external beam of 4 MV linac X-ray (total = 66 Gy). The AUC 1.5 combination group showed overall response, CR, 5-year survival, 10-year survival, 5-year larynx preservation, and 10-year larynx preservation rates of 100.0%, 68.0%, 83.4%, 77.0%, 75.2%, and 75.2%, respectively. The AUC 2.0 combination group showed corresponding rates of 100%, 96.0%, 95.7%, 91.1%, 82.9%, and 72.7%, respectively. The most common side effects of grade 3 or more were leukopenia, neutropenia, and mucositis (stomatitis), and all were reversible. Thirteen patients (52.0%) in the AUC 1.5 combination group and nine patients (36.0%) in the AUC 2.0 combination group required salvage surgery. Histologically, concurrent chemoradiation therapy with carboplatin caused more severe cancer tissue degeneration. Pathological examinations indicated that the safety margin for partial laryngectomy was 4 mm from the gross tumor.

  12. The highest energies in the Universe

    International Nuclear Information System (INIS)

    Rebel, H.

    2006-01-01

    There are not many issues of fundamental importance which have induced so many problems for astrophysicists like the question of the origin of cosmic rays. This radiation from the outer space has an energy density comparable with that of the visible starlight or of the microwave background radiation. It is an important feature of our environment with many interesting aspects. A most conspicuous feature is that the energy spectrum of cosmic rays seems to have no natural end, though resonant photopion production with the cosmic microwave background predicts a suppression of extragalactic protons above the so-called Greisen-Zatsepin-Kuz’min cutoff at about EGZK = 5 × 10"1"9 eV. In fact the highest particle energies ever observed on the Earth, stem from observations of Ultrahigh Energy Cosmic Rays (E > 3 × 10"1"9 eV). But the present observations by the AGASA and HiRes Collaborations, partly a matter of debate, are origin of a number of puzzling questions, where these particles are coming from, by which gigantic acceleration mechanism they could gain such tremendous energies and how they have been able to propagate to our Earth. These questions imply serious problems of the understanding of our Universe. There are several approaches to clarify the mysteries of the highest energies and to base the observations on larger statistical accuracy. The Pierre Auger Observatory, being in installation in the Pampa Amarilla in the Province Mendoza in Argentina, is a hybrid detector, combining a large array of water Cerenkov detectors (registering charged particles generated in giant extended air showers) with measurements of the fluorescence light produced during the air shower development. This contribution will illustrate the astrophysical motivation and the current status of the experimental efforts, and sketch the ideas about the origin of these particles.

  13. Gender differences in the accuracy of time-dependent blood pressure indices for predicting coronary heart disease: A random-effects modeling approach.

    Science.gov (United States)

    Brant, Larry J; Ferrucci, Luigi; Sheng, Shan L; Concin, Hans; Zonderman, Alan B; Kelleher, Cecily C; Longo, Dan L; Ulmer, Hanno; Strasak, Alexander M

    2010-12-01

    Previous studies on blood pressure (BP) indices as a predictor of coronary heart disease (CHD) have provided equivocal results and generally relied on Cox proportional hazards regression methodology, with age and sex accounting for most of the predictive capability of the model. The aim of the present study was to use serially collected BP measurements to examine age-and gender-related differences in BP indices for predicting CHD. The predictive accuracy of time-dependent BP indices for CHD was investigated using a method of risk prediction based on posterior probabilities calculated from mixed-effects regression to utilize intraindividual differences in serial BP measurements according to age changes within gender groups. Data were collected prospectively from 2 community-dwelling cohort studies in the United States (Baltimore Longitudinal Study of Aging [BLSA]) and Europe (Vorarlberg Health Monitoring and Promotion Program [VHM&PP]). The study comprised 152,633 participants (aged 30-74 years) and 610,061 BP measurements. During mean follow-up of 7.5 years, 2457 nonfatal and fatal CHD events were observed. In both study populations, pulse pressure (PP) and systolic blood pressure (SBP) performed best as individual predictors of CHD in women (area under the receiver operating characteristic curve [AUC(ROC)] was between 0.83 and 0.85 for PP, and between 0.77 and 0.81 for SBP). Mean arterial pressure (MAP) and diastolic blood pressure (DBP) performed better for men (AUC(ROC) = 0.67 and 0.65 for MAP and DBP, respectively, in the BLSA; AUC(ROC) = 0.77 and 0.75 in the VHM&PP) than for women (AUC(ROC) = 0.60 for both MAP and DBP in the BLSA; AUC(ROC) = 0.75 and 0.52, respectively, in the VHM&PP). The degree of discrimination in both populations was overall greater but more varied for all BP indices for women (AUC(ROC) estimates between 0.85 [PP in the VHM&PP] and 0.52 [DBP in the VHM&PP]) than for men (AUC(ROC) estimates between 0.78 [MAP + PP in the VHM&PP] and 0.63 [PP

  14. The accuracy of digital breast tomosynthesis compared with coned compression magnification mammography in the assessment of abnormalities found on mammography

    International Nuclear Information System (INIS)

    Morel, J.C.; Iqbal, A.; Wasan, R.K.; Peacock, C.; Evans, D.R.; Rahim, R.; Goligher, J.; Michell, M.J.

    2014-01-01

    Aim: To compare the diagnostic accuracy of the digital breast tomosynthesis (DBT) with coned compression magnification mammography (CCMM). Materials and methods: The study design included two reading sessions completed by seven experienced radiologists. In the first session, all readers read bilateral standard two-view mammograms and a CCMM view of the lesion before giving a combined score for assessment. In the second session, readers read bilateral standard two-view mammograms plus one-view DBT. The two reading sessions of the experiment were separated by at least 2 weeks to reduce the chance of reader memory of the images read in the previous session from influencing the performance in the subsequent session. Results: Three hundred and fifty-four lesions were assessed and receiver-operative characteristic (ROC) analysis was used to evaluate the difference between the two modes. For standard two-view mammography plus CCMM, the area under the curve (AUC) was 0.87 [95% confidence interval (CI): 0.83–0.91] and for standard two-view mammography plus DBT the AUC was 0.93 (95% CI: 0.91–0.95). The difference between the AUCs was 0.06 with p-value of 0.0014. Conclusion: Two-view mammography with one-view DBT showed significantly improved accuracy compared to two-view mammography and CCMM in the assessment of mammographic abnormalities. These results show that DBT can be used effectively in the further evaluation of mammographic abnormalities found at screening and in symptomatic diagnostic practice. - Highlights: • Diagnostic accuracy of magnification mammography and digital breast tomosynthesis. • There is statistical difference between CCMM and DBT. • DBT has a role in evaluating mammographic abnormalities

  15. Measurement of serum isoform [-2]proPSA derivatives shows superior accuracy to magnetic resonance imaging in the diagnosis of prostate cancer in patients with a total prostate-specific antigen level of 2-10 ng/ml.

    Science.gov (United States)

    Furuya, Kazuhiro; Kawahara, Takashi; Narahara, Masaki; Tokita, Takashi; Fukui, Sachi; Imano, Masashi; Mitome, Taku; Ito, Yusuke; Izumi, Koji; Osaka, Kimito; Yokomizo, Yumiko; Hayashi, Narihiko; Hasumi, Hisashi; Nawata, Shintaro; Kawano, Tsuyoshi; Yao, Masahiro; Uemura, Hiroji

    2017-08-01

    More accurate diagnostic procedures for prostate cancer are needed to avoid unnecessary biopsy due to the low specificity of prostate-specific antigen (PSA). Recent studies showed that the percentage of serum isoform [-2]proPSA (p2PSA) to free PSA (%p2PSA), the Prostate Health Index (PHI) and magnetic resonance imaging (MRI) were more accurate than PSA. The aim of this study was to test the accuracy of %p2PSA, PHI and MRI in discriminating patients with and without prostate cancer. The subjects were 50 consecutive men with a PSA level of 2.0-10.0 ng/ml, who underwent prostate biopsy from October 2012 to July 2014. These patients underwent multiparametric MRI before biopsy, and their serum samples were measured for PSA, free PSA and p2PSA. The sensitivity, specificity and accuracy of PHI, %p2PSA and MRI were compared with PSA in the diagnosis of biopsy-confirmed prostate cancer. In a univariate analysis, %p2PSA [area under the curve (AUC): 0.811] and PHI (AUC 0.795) were more accurate than MRI (AUC: 0.583) and PSA (AUC: 0.554) for prostate cancer detection. At 60% sensitivity, the specificity of PHI (76.5%) was higher than that of MRI (52.9%). For significant cancer detection, %p2PSA (AUC: 0.745), PHI (AUC: 0.791) and MRI (AUC: 0.739) were marginally more accurate than PSA (AUC: 0.696). At 85% sensitivity, the specificity of MRI (62.1%) was higher than that of PHI (34.5%). PHI and %p2PSA can be used for screening the general population and MRI can be used for detection of significant cancer in patients suspected, from screening tests, of having prostate cancer.

  16. Procalcitonin Improves the Glasgow Prognostic Score for Outcome Prediction in Emergency Patients with Cancer: A Cohort Study

    Directory of Open Access Journals (Sweden)

    Anna Christina Rast

    2015-01-01

    Full Text Available The Glasgow Prognostic Score (GPS is useful for predicting long-term mortality in cancer patients. Our aim was to validate the GPS in ED patients with different cancer-related urgency and investigate whether biomarkers would improve its accuracy. We followed consecutive medical patients presenting with a cancer-related medical urgency to a tertiary care hospital in Switzerland. Upon admission, we measured procalcitonin (PCT, white blood cell count, urea, 25-hydroxyvitamin D, corrected calcium, C-reactive protein, and albumin and calculated the GPS. Of 341 included patients (median age 68 years, 61% males, 81 (23.8% died within 30 days after admission. The GPS showed moderate prognostic accuracy (AUC 0.67 for mortality. Among the different biomarkers, PCT provided the highest prognostic accuracy (odds ratio 1.6 (95% confidence interval 1.3 to 1.9, P<0.001, AUC 0.69 and significantly improved the GPS to a combined AUC of 0.74 (P=0.007. Considering all investigated biomarkers, the AUC increased to 0.76 (P<0.001. The GPS performance was significantly improved by the addition of PCT and other biomarkers for risk stratification in ED cancer patients. The benefit of early risk stratification by the GPS in combination with biomarkers from different pathways should be investigated in further interventional trials.

  17. AUC-Guided Vancomycin Dosing in Adolescent Patients With Suspected Sepsis.

    Science.gov (United States)

    Lanke, Shankar; Yu, Tian; Rower, Joseph E; Balch, Alfred H; Korgenski, E Kent; Sherwin, Catherine M

    2017-01-01

    Vancomycin is a first-line treatment for β-lactam-resistant Gram-positive bacterial infections. Understanding the pharmacokinetic (PK) and pharmacodynamic (PD) characteristics of vancomycin in an adolescent population is of clinical importance in this often overlooked pediatric population. This retrospective study investigated vancomycin PK-PD in an adolescent cohort (12 to 18 years of age) of 463 patients (57% male, 81% white) admitted to the Intermountain Healthcare System between January 2006 and December 2013. Population PK modeling was performed in NONMEM 7.3. Vancomycin PK was well described with a 1-compartment model that identified both body weight (WT) and creatinine clearance (CRCL) as covariates significantly impacting vancomycin disposition. The model was then utilized to determine dosing strategies that achieved the targeted area under the 24-hour time curve vs minimum inhibitory concentration (AUC 0-24 /MIC) ratio of ≥400. Additionally, these data were correlated with minimum steady-state concentrations (C ss,min ) to find an acceptable target trough concentration range in adolescents. This analysis demonstrated that C ss,min ranging from 10 to 12.5 mg/L were highly predictive of achieving an AUC 0-24 /MIC ≥400 when the MIC was ≤1 mg/L. These results suggest that the target trough concentration for adolescents may be lower than that for adults. © 2016, The American College of Clinical Pharmacology.

  18. Mycophenolic acid AUC in Thai kidney transplant recipients receiving low dose mycophenolate and its association with UGT2B7 polymorphisms.

    Science.gov (United States)

    Pithukpakorn, Manop; Tiwawanwong, Tiwat; Lalerd, Yupaporn; Assawamakin, Anunchai; Premasathian, Nalinee; Tasanarong, Adis; Thongnoppakhun, Wanna; Vongwiwatana, Attapong

    2014-01-01

    Despite use of a lower mycophenolate dose in Thai kidney transplant patients, acceptable graft and patient outcomes can be achieved. We therefore examined the pharmacokinetics of mycophenolic acid (MPA) by area under the curve (AUC) and investigated genetic contribution in mycophenolate metabolism in this population. Kidney transplant recipients with stable graft function who were receiving mycophenolate mofetil 1,000 mg/d in combination with either cyclosporine or tacrolimus, and prednisolone were studied. The MPA concentration was measured by fluorescence polarization immunoassay (FPIA), at predose and 1, 1.5, 2, 4, 6, 8, 10, and 12 hours after dosing. Genetic polymorphisms in UGT1A8, UGT1A9, and UGT2B7 were examined by denaturing high-performance liquid chromatography (DHPLC)-based single-base extension (SBE) analysis. A total 138 patients were included in study. The mean AUC was 39.49 mg-h/L (28.39-89.58 mg-h/L), which was in the therapeutic range. The correlation between the predose MPA concentration and AUC was poor. The mean AUC in the tacrolimus group was higher than that in the cyclosporine group. Polymorphisms in UGT2B7 showed significant association with AUC. Most of our patients with reduced mycophenolate dose had the AUC within the therapeutic range. Genetic polymorphisms in UGT2B7 may play a role in MPA metabolism in Thai kidney transplant patients.

  19. Stable Au-C bonds to the substrate for fullerene-based nanostructures

    Czech Academy of Sciences Publication Activity Database

    Chutora, Taras; López, Roso Redondo Jesús R.; De La Torre Cerdeño, Bruno; Švec, Martin; Jelínek, Pavel; Vázquez, Héctor

    2017-01-01

    Roč. 8, č. 1 (2017), s. 1073-1079 ISSN 2190-4286 R&D Projects: GA ČR GA15-19672S Institutional support: RVO:68378271 Keywords : Au-C bonds * density functional theory (DFT) * fullerenes * scanning tunneling microscopy (STM) * sputtering Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 3.127, year: 2016

  20. Intranasal Pharmacokinetic Data for Triptans Such as Sumatriptan and Zolmitriptan Can Render Area Under the Curve (AUC) Predictions for the Oral Route: Strategy Development and Application.

    Science.gov (United States)

    Srinivas, Nuggehally R; Syed, Muzeeb

    2016-01-01

    Limited pharmacokinetic sampling strategy may be useful for predicting the area under the curve (AUC) for triptans and may have clinical utility as a prospective tool for prediction. Using appropriate intranasal pharmacokinetic data, a Cmax vs. AUC relationship was established by linear regression models for sumatriptan and zolmitriptan. The predictions of the AUC values were performed using published mean/median Cmax data and appropriate regression lines. The quotient of observed and predicted values rendered fold-difference calculation. The mean absolute error (MAE), mean positive error (MPE), mean negative error (MNE), root mean square error (RMSE), correlation coefficient (r), and the goodness of the AUC fold prediction were used to evaluate the two triptans. Also, data from the mean concentration profiles at time points of 1 hour (sumatriptan) and 3 hours (zolmitriptan) were used for the AUC prediction. The Cmax vs. AUC models displayed excellent correlation for both sumatriptan (r = .9997; P AUCs (83%-85%) were within 0.76-1.25-fold difference using the regression model. The prediction of AUC values for sumatriptan or zolmitriptan using the concentration data that reflected the Tmax occurrence were in the proximity of the reported values. In summary, the Cmax vs. AUC models exhibited strong correlations for sumatriptan and zolmitriptan. The usefulness of the prediction of the AUC values was established by a rigorous statistical approach.

  1. Diagnostic accuracy of fluorine-18-fluorodeoxyglucose positron emission tomography in gallbladder cancer: A meta-analysis.

    Science.gov (United States)

    Annunziata, Salvatore; Pizzuto, Daniele Antonio; Caldarella, Carmelo; Galiandro, Federica; Sadeghi, Ramin; Treglia, Giorgio

    2015-10-28

    To meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the evaluation of primary tumor in patients with gallbladder cancer (GBCa). A comprehensive literature search of studies published through 30(th) June 2014 regarding the role of (18)F-FDG PET and PET/CT in the evaluation of primary gallbladder cancer (GBCa) was performed. All retrieved studies were reviewed. Pooled sensitivity and specificity of (18)F-FDG PET or PET/CT in the evaluation of primary GBCa were calculated. The area under the summary receiving operator characteristics curve (AUC) was calculated to measure the accuracy of these methods. Sub-analyses considering the device used (PET vs PET/CT) were carried out. Twenty-one studies comprising 495 patients who underwent (18)F-FDG PET or PET/CT for suspicious GBCa were selected for the systematic review. The meta-analysis of 13 selected studies provided the following results: sensitivity 87% (95%CI: 82%-92%), specificity 78% (95%CI: 68%-86%). The AUC was 0.88. Improvement of sensitivity and specificity was observed when PET/CT was used. (18)F-FDG-PET and PET/CT demonstrated to be useful diagnostic imaging methods in the assessment of primary tumor in GBCa patients, nevertheless possible sources of false-negative and false-positive results should be kept in mind. PET/CT seems to have a better diagnostic accuracy than PET alone in this setting.

  2. Exploration of analysis methods for diagnostic imaging tests: problems with ROC AUC and confidence scores in CT colonography.

    Science.gov (United States)

    Mallett, Susan; Halligan, Steve; Collins, Gary S; Altman, Doug G

    2014-01-01

    Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests.

  3. [Safe and effective administration of carboplatin-based chemotherapy in a patient undergoing hemodialysis with cancer of unknown primary by monitoring observed AUC of carboplatin-a case report].

    Science.gov (United States)

    Kondo, Masahiro; Kuroda, Junko; Ikai, Yoshitomo; Hayashi, Rumiko; Uegaki, Shiori; Yoshida, Tatsuya; Yoshida, Atsuhiro; Komatsu, Hirokazu; Kimura, Kazunori

    2012-11-01

    Here we report a case of successful treatment with combination chemotherapy of carboplatin(CBDCA)and paclitaxel for a patient undergoing hemodialysis(HD)with cancer of unknown primary, conducted by monitoring the observed AUC of ultrafilterable CBDCA. CBDCA was administered at a dose of 125 mg on day 1 in each course, an amount which had been calculated by the Calvert formula(GFR: 0, target AUC: 5). HD was started at a point in time one hour after the completion of each CBDCA administration, and performed for 5 hours in each course. Blood samples were collected during the first 3 courses of chemotherapy to measure the plasma concentration of free-platinum. The observed AUCs(o-AUC)of CBDCA in the first, second and third courses were 3. 03, 3. 44 and 3. 50mg·min/mL, respectively. The o-AUC in the first course was lower than that in the second course. The o-AUC in the second course was nearly equal to that in the third course, while each o-AUC was below the target AUC(t-AUC). Partial response was achieved after two courses of the CBDCA and paclitaxel combination chemotherapy, with adverse events of Grade 3 neutropenia and Grade 3 peripheral neuropathy observed in each course after the second course of chemotherapy. o-AUC of CBDCA administered to HD patients can not only be below t-AUC, as in this case, but also oppositely above t-AUC in cases with different doses of CBDCA or HD settings. Our results suggest that the monitoring of o-AUC of CBDCA is useful when practicing CBDCA-based chemotherapy safely and effectively in cancer patients undergoing HD.

  4. Quantifying and comparing dynamic predictive accuracy of joint models for longitudinal marker and time-to-event in presence of censoring and competing risks

    DEFF Research Database (Denmark)

    Blanche, Paul; Proust-Lima, Cécile; Loubère, Lucie

    2015-01-01

    to quantify predictive accuracy. Nonparametric inverse probability of censoring weighting is used to estimate dynamic curves of AUC and BS as functions of the time at which predictions are made. Asymptotic results are established and both pointwise confidence intervals and simultaneous confidence bands...

  5. Development of AUC-based process at BARC for production of free-flowing and sinterable UO2 powder

    International Nuclear Information System (INIS)

    Keni, V.S.; Ghosh, S.K.; Ganguly, C.; Majumdar, S.

    1994-01-01

    Ammonium uranium carbonate (AUC) process has been developed and industrially used in Germany for preparation of free-flowing and sinterable UO 2 powder for fabrication of UO 2 fuel pellets for light water reactors (LWR). Efforts are underway at Bhabha Atomic Research Centre (BARC) for developing AUC-based process which would yield free-flowing UO 2 powder suitable for direct pelletisation and sintering to very high density (> 96% T.D.) UO 2 fuel pellets for pressurised heavy water reactors (PHWRs) in India. The first phase of this work has been completed jointly by Chemical Engineering Division (ChED) and Radiometallurgy Division (RMD) in batches of 1.5 kg. It was possible to fabricate UO 2 pellets of density 93-95% T.D. on a reproducible basis. At ChED, process parameters have been optimised for fabrication of AUC with suitable physical properties in batches of 1.5 kg (U), starting with nuclear pure uranyl nitrate solution. At RMD calcination parameters of AUC was optimised in batches of 500 g for obtaining free-flowing UO 2 powder, suitable for direct pelletisation and sintering. The pelletisation and sintering have been carried out at Radiometallurgy Division in batches of 1-1.5 kg. The maximum achievable density of UO 2 pellets has been in the range of 95.5-96% T.D. (author). 11 refs

  6. [The Academy of Trauma Surgery (AUC). Service provider and management organization of the DGU].

    Science.gov (United States)

    Sturm, J A; Hoffmann, R

    2016-02-01

    At the beginning of this century the German Trauma Society (DGU) became extensively active with an initiative on quality promotion, development of quality assurance and transparency regarding treatment of the severely injured. A white book on "Medical care of the severely injured" was published, focusing on the requirements on structural quality and especially procedural quality. The impact of the white book was immense and a trauma network with approved trauma centers, structured and graded for their individual trauma care performance, was developed. In order to monitor and document the required quality of care, a registry was needed. Furthermore, for cooperation within the trauma networks innovative methods for digital transfer of radiological images and patient documents became necessary. Finally, the auditing criteria for trauma centers had and still have to be completed with advanced medical education and training programs. In order to realize the implementation of such a broad spectrum of economically relevant and increasingly complex activities the Academy of Trauma Surgery (AUC) was established as a subsidiary of the DGU in 2004. The AUC currently has four divisions: 1) networks and health care structures, 2) registries and research management, 3) telemedicine, 4) medical education and training, all of which serve the goal of the initiative. The AUC is a full service provider and management organization in compliance with the statutes of the DGU. According to these statutes the business operations of the AUC also cover projects for numerous groups of patients, projects for the joint society the German Society for Orthopedics and Trauma (DGOU) as well as other medical institutions. This article describes the success stories of the trauma network (TraumaNetzwerk DGU®), the TraumaRegister DGU®, the telecooperation platform TKmed®, the new and fast-growing orthogeriatric center initiative (AltersTraumaZentrum DGU®) and the division of medical education and

  7. The impact of new partial AUC parameters for evaluating the bioequivalence of prolonged-release formulations.

    Science.gov (United States)

    Boily, Michaël; Dussault, Catherine; Massicotte, Julie; Guibord, Pascal; Lefebvre, Marc

    2015-01-23

    To demonstrate bioequivalence (BE) between two prolonged-release (PR) drug formulations, single dose studies under fasting and fed state as well as at least one steady-state study are currently required by the European Medicines Agency (EMA). Recently, however, there have been debates regarding the relevance of steady-state studies. New requirements in single-dose investigations have also been suggested by the EMA to address the absence of a parameter that can adequately assess the equivalence of the shape of the curves. In the draft guideline issued in 2013, new partial area under the curve (pAUC) pharmacokinetic (PK) parameters were introduced to that effect. In light of these potential changes, there is a need of supportive clinical evidence to evaluate the impact of pAUCs on the evaluation of BE between PR formulations. In this retrospective analysis, it was investigated whether the newly defined parameters were associated with an increase in discriminatory ability or a change in variability compared to the conventional PK parameters. Among the single dose studies that met the requirements already in place, 20% were found unable to meet the EMA's new requirements in regards to the pAUC PK parameters. When pairing fasting and fed studies for a same formulation, the failure rate increased to 40%. In some cases, due to the high variability of these parameters, an increase of the sample size would be required to prove BE. In other cases however, the pAUC parameters demonstrated a robust ability to detect differences between the shapes of the curves of PR formulations. The present analysis should help to better understand the impact of the upcoming changes in European regulations on PR formulations and in the design of future BE studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Adults with suspected central nervous system infection: A prospective study of diagnostic accuracy.

    Science.gov (United States)

    Khatib, Ula; van de Beek, Diederik; Lees, John A; Brouwer, Matthijs C

    2017-01-01

    To study the diagnostic accuracy of clinical and laboratory features in the diagnosis of central nervous system (CNS) infection and bacterial meningitis. We included consecutive adult episodes with suspected CNS infection who underwent cerebrospinal fluid (CSF) examination. The reference standard was the diagnosis classified into five categories: 1) CNS infection; 2) CNS inflammation without infection; 3) other neurological disorder; 4) non-neurological infection; and 5) other systemic disorder. Between 2012 and 2015, 363 episodes of suspected CNS infection were included. CSF examination showed leucocyte count >5/mm 3 in 47% of episodes. Overall, 89 of 363 episodes were categorized as CNS infection (25%; most commonly viral meningitis [7%], bacterial meningitis [7%], and viral encephalitis [4%]), 36 (10%) episodes as CNS inflammatory disorder, 111 (31%) as systemic infection, in 119 (33%) as other neurological disorder, and 8 (2%) as other systemic disorders. Diagnostic accuracy of individual clinical characteristics and blood tests for the diagnosis of CNS infection or bacterial meningitis was low. CSF leucocytosis differentiated best between bacterial meningitis and other diagnoses (area under the curve [AUC] 0.95) or any neurological infection versus other diagnoses (AUC 0.93). Clinical characteristics fail to differentiate between neurological infections and other diagnoses, and CSF analysis is the main contributor to the final diagnosis. Copyright © 2016 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  9. Diagnostic and prognostic accuracy of clinical and laboratory parameters in community-acquired pneumonia

    Directory of Open Access Journals (Sweden)

    Nusbaumer Charly

    2007-03-01

    Full Text Available Abstract Background Community-acquired pneumonia (CAP is the most frequent infection-related cause of death. The reference standard to diagnose CAP is a new infiltrate on chest radiograph in the presence of recently acquired respiratory signs and symptoms. This study aims to evaluate the diagnostic and prognostic accuracy of clinical signs and symptoms and laboratory biomarkers for CAP. Methods 545 patients with suspected lower respiratory tract infection, admitted to the emergency department of a university hospital were included in a pre-planned post-hoc analysis of two controlled intervention trials. Baseline assessment included history, clinical examination, radiography and measurements of procalcitonin (PCT, highly sensitive C-reactive protein (hsCRP and leukocyte count. Results Of the 545 patients, 373 had CAP, 132 other respiratory tract infections, and 40 other final diagnoses. The AUC of a clinical model including standard clinical signs and symptoms (i.e. fever, cough, sputum production, abnormal chest auscultation and dyspnea to diagnose CAP was 0.79 [95% CI, 0.75–0.83]. This AUC was significantly improved by including PCT and hsCRP (0.92 [0.89–0.94]; p Conclusion PCT, and to a lesser degree hsCRP, improve the accuracy of currently recommended approaches for the diagnosis of CAP, thereby complementing clinical signs and symptoms. PCT is useful in the severity assessment of CAP.

  10. Local epidemiology and resistance profiles in acute uncomplicated cystitis (AUC) in women: a prospective cohort study in an urban urological ambulatory setting.

    Science.gov (United States)

    Seitz, Michael; Stief, Christian; Waidelich, Raphaela

    2017-10-16

    Acute uncomplicated cystitis (AUC) is a common ailment in the urological setting. Guidelines for urinary tract infections are based on large-scale multi-centre, epidemiological and international studies. The objective of this observational study was to establish whether the results of a multi-centre study on the resistance profile of Escherichia coli (E. coli) in patients with AUC could be directly applied to an urological practice in a major European city or whether there are divergences in the resistance profile. An observational study was applied prospectively to 502 patients with AUC between January 2015 and January 2017). Personal data were anonymised. Exclusion criteria were the patient's age (AUC should therefore only be treated with TRS, CIP and AMC after a susceptibility test has been carried out.

  11. Diagnostic Accuracy of APRI, AAR, FIB-4, FI, and King Scores for Diagnosis of Esophageal Varices in Liver Cirrhosis: A Retrospective Study.

    Science.gov (United States)

    Deng, Han; Qi, Xingshun; Peng, Ying; Li, Jing; Li, Hongyu; Zhang, Yongguo; Liu, Xu; Sun, Xiaolin; Guo, Xiaozhong

    2015-12-20

    BACKGROUND Aspartate aminotransferase-to-platelet ratio index (APRI), aspartate aminotransferase-to-alanine aminotransferase ratio (AAR), FIB-4, fibrosis index (FI), and King scores might be alternatives to the use of upper gastrointestinal endoscopy for the diagnosis of esophageal varices (EVs) in liver cirrhosis. This study aimed to evaluate their diagnostic accuracy in predicting the presence and severity of EVs in liver cirrhosis. MATERIAL AND METHODS All patients who were consecutively admitted to our hospital and underwent upper gastrointestinal endoscopy between January 2012 and June 2014 were eligible for this retrospective study. Areas under curve (AUCs) were calculated. Subgroup analyses were performed according to the history of upper gastrointestinal bleeding (UGIB) and splenectomy. RESULTS A total of 650 patients with liver cirrhosis were included, and 81.4% of them had moderate-severe EVs. In the overall analysis, the AUCs of these non-invasive scores for predicting moderate-severe EVs and presence of any EVs were 0.506-0.6 and 0.539-0.612, respectively. In the subgroup analysis of patients without UGIB, their AUCs for predicting moderate-severe varices and presence of any EVs were 0.601-0.664 and 0.596-0.662, respectively. In the subgroup analysis of patients without UGIB or splenectomy, their AUCs for predicting moderate-severe varices and presence of any EVs were 0.627-0.69 and 0.607-0.692, respectively. CONCLUSIONS APRI, AAR, FIB-4, FI, and King scores had modest diagnostic accuracy of EVs in liver cirrhosis. They might not be able to replace the utility of upper gastrointestinal endoscopy for the diagnosis of EVs in liver cirrhosis.

  12. Hydrodynamic Modeling and Its Application in AUC.

    Science.gov (United States)

    Rocco, Mattia; Byron, Olwyn

    2015-01-01

    The hydrodynamic parameters measured in an AUC experiment, s(20,w) and D(t)(20,w)(0), can be used to gain information on the solution structure of (bio)macromolecules and their assemblies. This entails comparing the measured parameters with those that can be computed from usually "dry" structures by "hydrodynamic modeling." In this chapter, we will first briefly put hydrodynamic modeling in perspective and present the basic physics behind it as implemented in the most commonly used methods. The important "hydration" issue is also touched upon, and the distinction between rigid bodies versus those for which flexibility must be considered in the modeling process is then made. The available hydrodynamic modeling/computation programs, HYDROPRO, BEST, SoMo, AtoB, and Zeno, the latter four all implemented within the US-SOMO suite, are described and their performance evaluated. Finally, some literature examples are presented to illustrate the potential applications of hydrodynamics in the expanding field of multiresolution modeling. © 2015 Elsevier Inc. All rights reserved.

  13. On the Derivation of Highest-Order Compact Finite Difference Schemes for the One- and Two-Dimensional Poisson Equation with Dirichlet Boundary Conditions

    KAUST Repository

    Settle, Sean O.

    2013-01-01

    The primary aim of this paper is to answer the question, What are the highest-order five- or nine-point compact finite difference schemes? To answer this question, we present several simple derivations of finite difference schemes for the one- and two-dimensional Poisson equation on uniform, quasi-uniform, and nonuniform face-to-face hyperrectangular grids and directly prove the existence or nonexistence of their highest-order local accuracies. Our derivations are unique in that we do not make any initial assumptions on stencil symmetries or weights. For the one-dimensional problem, the derivation using the three-point stencil on both uniform and nonuniform grids yields a scheme with arbitrarily high-order local accuracy. However, for the two-dimensional problem, the derivation using the corresponding five-point stencil on uniform and quasi-uniform grids yields a scheme with at most second-order local accuracy, and on nonuniform grids yields at most first-order local accuracy. When expanding the five-point stencil to the nine-point stencil, the derivation using the nine-point stencil on uniform grids yields at most sixth-order local accuracy, but on quasi- and nonuniform grids yields at most fourth- and third-order local accuracy, respectively. © 2013 Society for Industrial and Applied Mathematics.

  14. Spectroscopic Identification of the Au-C Bond Formation upon Electroreduction of an Aryl Diazonium Salt on Gold.

    Science.gov (United States)

    Guo, Limin; Ma, Lipo; Zhang, Yelong; Cheng, Xun; Xu, Ye; Wang, Jin; Wang, Erkang; Peng, Zhangquan

    2016-11-08

    Electroreduction of aryl diazonium salts on gold can produce organic films that are more robust than their analogous self-assembled monolayers formed from chemical adsorption of organic thiols on gold. However, whether the enhanced stability is due to the Au-C bond formation remains debated. In this work, we report the electroreduction of an aryl diazonium salt of 4,4'-disulfanediyldibenzenediazonium on gold forming a multilayer of Au-(Ar-S-S-Ar) n , which can be further degraded to a monolayer of Au-Ar-S - by electrochemical cleavage of the S-S moieties within the multilayer. By conducting an in situ surface-enhanced Raman spectroscopic study of both the multilayer formation/degradation and the monolayer reduction/oxidation processes, coupled to density functional theory calculations, we provide compelling evidence that an Au-C bond does form upon electroreduction of aryl diazonium salts on gold and that the enhanced stability of the electrografted organic films is due to the Au-C bond being intrinsically stronger than the Au-S bond for a given phenylthiolate compound by ca. 0.4 eV.

  15. Carbonated water (CW) process waste reuse for ammonium-uranyl-carbonate (AUC) production and its gains on the environmental, economic and social aspects

    International Nuclear Information System (INIS)

    Carnaval, Joao Paulo R.; Santos, Rafael D. dos; Barbosa, Rodrigo A.; Lauer, Sergio

    2013-01-01

    In the INB nuclear fuel cycle, the pellets production is based on UO 2 powder made by AUC (Ammonium-Uranyl-Carbonate) route. AUC formation occurs by fluidising of UF 6 , NH 3 and CO 2 in a vase containing usually pure water, and this exothermal reaction has AUC as direct product. The mass formed is filtered, washed with CW, washed again with methano solution, dried with air and conducted to the fluidized bed furnace, to be converted to UO 2 powder. At this point, the dried AUC decompounds to UO 3 , NH 3 and C0 2 , these 2 gases are absorbed at the gases washer, formin go the carbonated water (CW), whit is basically a (NH 4 ) 2 CO 3 solution. The UO 2+x is reduced and stabilized to UO 2 powder, which is conducted to pellets production. During the process, a considerable amount of this aqueous waste is generated and goes for effluent treatment. After that, the solution is sent for spray-dryer for power formation, and stock. This treatment demands equipment, energy and time, representing considerable costs of the company beyond the human risks involved on the drying step. The purpose of this work is to present a study of the carbonated water use as substitute of pure water in the AUC formation step. At this point, tests were made varying the CW loads for the AUC precipitation, and the control was made by the UO 2 powder properties. The carbonated water used for AUC precipitation has been tested at several levels and the results has demonstrated full viability to become a definitive process step (INB, Resende site). It has been demonstrated the great resources economy caused by the waste reuse and the guarantee product quality. This represents such an environmental gain and also economic and social aspects got improved. (author)

  16. Diagnostic Accuracies of Glycated Hemoglobin, Fructosamine, and Homeostasis Model Assessment of Insulin Resistance in Predicting Impaired Fasting Glucose, Impaired Glucose Tolerance, or New Onset Diabetes After Transplantation.

    Science.gov (United States)

    Rosettenstein, Kerri; Viecelli, Andrea; Yong, Kenneth; Nguyen, Hung Do; Chakera, Aron; Chan, Doris; Dogra, Gursharan; Lim, Ee Mun; Wong, Germaine; Lim, Wai H

    2016-07-01

    New onset diabetes after transplantation (NODAT) is associated with a 3-fold greater risk of cardiovascular disease events, with early identification and treatment potentially attenuating this risk. The optimal screening test to identify those with NODAT remains unclear, and the aim of this study was to examine the diagnostic accuracies of 4 screening tests in identifying impaired fasting glucose, impaired glucose tolerance (IGT), and NODAT. This is a single-center prospective cohort study of 83 nondiabetic kidney transplant recipients between 2008 and 2011. Oral glucose tolerance test was considered the gold standard in identifying IFG/IGT or NODAT. Diagnostic accuracies of random blood glucose, glycated hemoglobin (HBA1c), fructosamine, and Homeostasis Model Assessment-Insulin Resistance in predicting IFG/IGT or NODAT were assessed using the area under the receiver operating characteristic curve. Forty (48%) recipients had IFG/IGT or NODAT. Compared with HBA1c with adjusted area under the curve (AUC) of 0.88 (95% confidence interval [95% CI], 0.77-0.93), fructosamine was the most accurate test with adjusted AUC of 0.92 (95% CI, 0.83-0.96). The adjusted AUCs of random blood glucose and Homeostasis Model Assessment-Insulin Resistance in identifying IFG/IGT were between 0.81 and 0.85. Restricting to identifying IGT/NODAT using 2-hour oral glucose tolerance test (n = 66), fructosamine was the most accurate diagnostic test with adjusted AUC of 0.93 (95% CI, 0.84-0.99), but not statistically different to HBA1c with adjusted AUC of 0.88 (95% CI, 0.76-0.96). Although HBA1c is an acceptable and widely used screening test in detecting IFG/IGT or NODAT, fructosamine may be a more accurate diagnostic test but this needs to be further examined in larger cohorts.

  17. Quantifying and comparing dynamic predictive accuracy of joint models for longitudinal marker and time-to-event in presence of censoring and competing risks.

    Science.gov (United States)

    Blanche, Paul; Proust-Lima, Cécile; Loubère, Lucie; Berr, Claudine; Dartigues, Jean-François; Jacqmin-Gadda, Hélène

    2015-03-01

    Thanks to the growing interest in personalized medicine, joint modeling of longitudinal marker and time-to-event data has recently started to be used to derive dynamic individual risk predictions. Individual predictions are called dynamic because they are updated when information on the subject's health profile grows with time. We focus in this work on statistical methods for quantifying and comparing dynamic predictive accuracy of this kind of prognostic models, accounting for right censoring and possibly competing events. Dynamic area under the ROC curve (AUC) and Brier Score (BS) are used to quantify predictive accuracy. Nonparametric inverse probability of censoring weighting is used to estimate dynamic curves of AUC and BS as functions of the time at which predictions are made. Asymptotic results are established and both pointwise confidence intervals and simultaneous confidence bands are derived. Tests are also proposed to compare the dynamic prediction accuracy curves of two prognostic models. The finite sample behavior of the inference procedures is assessed via simulations. We apply the proposed methodology to compare various prediction models using repeated measures of two psychometric tests to predict dementia in the elderly, accounting for the competing risk of death. Models are estimated on the French Paquid cohort and predictive accuracies are evaluated and compared on the French Three-City cohort. © 2014, The International Biometric Society.

  18. Diagnostic accuracy of an artificial neural network compared with statistical quantitation of myocardial perfusion images. A Japanese multicenter study

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kenichi; Matsuo, Shinro [Kanazawa University Hospital, Kanazawa (Japan); Kudo, Takashi [Nagasaki University Hospital, Nagasaki (Japan); Nakata, Tomoaki [Hakodate Goryoukaku Hospital, Hakodate (Japan); Kiso, Keisuke [National Cerebral and Cardiovascular Center, Suita (Japan); Kasai, Tokuo [Tokyo Medical University Hachioji Medical Center, Hachioji (Japan); Taniguchi, Yasuyo [Hyogo Brain and Heart Center, Himeji (Japan); Momose, Mitsuru [Tokyo Women' s Medical University, Tokyo (Japan); Nakagawa, Masayasu [Akita City Hospital, Akita (Japan); Sarai, Masayoshi [Fujita Health University Hospital, Toyoake (Japan); Hida, Satoshi [Tokyo Medical University Hospital, Tokyo (Japan); Tanaka, Hirokazu [Tokyo Medical University Ibaraki Medical Center, Ibaraki (Japan); Yokoyama, Kunihiko [Public Central Hospital of Matto Ishikawa, Hakusan (Japan); Okuda, Koichi [Kanazawa Medical University, Kahoku (Japan); Edenbrandt, Lars [University of Gothenburg, Gothenburg (Sweden)

    2017-12-15

    Artificial neural networks (ANN) might help to diagnose coronary artery disease. This study aimed to determine whether the diagnostic accuracy of an ANN-based diagnostic system and conventional quantitation are comparable. The ANN was trained to classify potentially abnormal areas as true or false based on the nuclear cardiology expert interpretation of 1001 gated stress/rest {sup 99m}Tc-MIBI images at 12 hospitals. The diagnostic accuracy of the ANN was compared with 364 expert interpretations that served as the gold standard of abnormality for the validation study. Conventional summed stress/rest/difference scores (SSS/SRS/SDS) were calculated and compared with receiver operating characteristics (ROC) analysis. The ANN generated a better area under the ROC curves (AUC) than SSS (0.92 vs. 0.82, p < 0.0001), indicating better identification of stress defects. The ANN also generated a better AUC than SDS (0.90 vs. 0.75, p < 0.0001) for stress-induced ischemia. The AUC for patients with old myocardial infarction based on rest defects was 0.97 (0.91 for SRS, p = 0.0061), and that for patients with and without a history of revascularization based on stress defects was 0.94 and 0.90 (p = 0.0055 and p < 0.0001 vs. SSS, respectively). The SSS/SRS/SDS steeply increased when ANN values (probability of abnormality) were >0.80. The ANN was diagnostically accurate in various clinical settings, including that of patients with previous myocardial infarction and coronary revascularization. The ANN could help to diagnose coronary artery disease. (orig.)

  19. Diagnostic accuracy of an artificial neural network compared with statistical quantitation of myocardial perfusion images. A Japanese multicenter study

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Matsuo, Shinro; Kudo, Takashi; Nakata, Tomoaki; Kiso, Keisuke; Kasai, Tokuo; Taniguchi, Yasuyo; Momose, Mitsuru; Nakagawa, Masayasu; Sarai, Masayoshi; Hida, Satoshi; Tanaka, Hirokazu; Yokoyama, Kunihiko; Okuda, Koichi; Edenbrandt, Lars

    2017-01-01

    Artificial neural networks (ANN) might help to diagnose coronary artery disease. This study aimed to determine whether the diagnostic accuracy of an ANN-based diagnostic system and conventional quantitation are comparable. The ANN was trained to classify potentially abnormal areas as true or false based on the nuclear cardiology expert interpretation of 1001 gated stress/rest 99m Tc-MIBI images at 12 hospitals. The diagnostic accuracy of the ANN was compared with 364 expert interpretations that served as the gold standard of abnormality for the validation study. Conventional summed stress/rest/difference scores (SSS/SRS/SDS) were calculated and compared with receiver operating characteristics (ROC) analysis. The ANN generated a better area under the ROC curves (AUC) than SSS (0.92 vs. 0.82, p < 0.0001), indicating better identification of stress defects. The ANN also generated a better AUC than SDS (0.90 vs. 0.75, p < 0.0001) for stress-induced ischemia. The AUC for patients with old myocardial infarction based on rest defects was 0.97 (0.91 for SRS, p = 0.0061), and that for patients with and without a history of revascularization based on stress defects was 0.94 and 0.90 (p = 0.0055 and p < 0.0001 vs. SSS, respectively). The SSS/SRS/SDS steeply increased when ANN values (probability of abnormality) were >0.80. The ANN was diagnostically accurate in various clinical settings, including that of patients with previous myocardial infarction and coronary revascularization. The ANN could help to diagnose coronary artery disease. (orig.)

  20. Obtainment of UO{sub 2} ex AUC (ammonium uranyl carbonate) from uranyl fluoride; Obtencion de UO{sub 2} ex AUC (carbonato de uranil amonio) partiendo de fluoruro de uranilo

    Energy Technology Data Exchange (ETDEWEB)

    Fuente, M de la; Gonzalez, A G; Gonzalez Scardaone, S; Perez de Perel, L; Marajofsky, A [Comision Nacional de Energia Atomica, San Martin (Argentina). Unidad de Actividad Combustibles Nucleares

    1997-12-31

    It is proposed the production of enriched UO{sub 2} powder starting from UF6 with the desired isotopic concentration in order to avoid the possible segregation inconveniences that take place in the mixture of enriched and natural UO{sub 2} powders. In this work is shown the feasibility of obtaining powders with direct sinterability, through the precipitation of uranyl fluoride solutions (UF{sub 6} hydrolysis). The AUC is a crystalline forerunner used in the powder production line. A simulated hydrolyzed UF{sub 6} solution was obtained by means of the dissolution of UO{sub 3} with FH acid. The precipitation operation was carried out in a discontinuous operation device, with simultaneous pumping. The precipitating media is achieved by adding simultaneously NH{sub 3} (g) and CO{sub 2} (g), using ejector nozzles during precipitation. Mother waters pH during precipitation stay between 8.5 and 9.2 and the temperature of operation is around 323 K. The AUC calcination, reduction and passivation took place during the same operation. The reduction was carried out at three different temperatures, 823 K, 933 K and 1003 K in H{sub 2} reducing atmosphere. The passivation was carried out at 343 K. The main problem of this process is free fluorine that could remain in the powder. It would inhibit its use as nuclear fuel, since the international specifications do not tolerate more than 20 mg/kg. However, the determinations carried out in all the cases, showed that it was completely eliminated during calcination. The ex AUC UO{sub 2} powders obtained from solution of F{sub 2} (UO{sub 2}) were fluoride free, showed specific areas within specification and good sinterability. Therefore it is possible to fabricate enriched powders using a humid process from F{sub 6}U, to be used without problems of segregation due to the origin of the powder mix in PWR fuels type (CAREM). (author). 3 figs.

  1. Computer-Aided Diagnosis for Breast Ultrasound Using Computerized BI-RADS Features and Machine Learning Methods.

    Science.gov (United States)

    Shan, Juan; Alam, S Kaisar; Garra, Brian; Zhang, Yingtao; Ahmed, Tahira

    2016-04-01

    This work identifies effective computable features from the Breast Imaging Reporting and Data System (BI-RADS), to develop a computer-aided diagnosis (CAD) system for breast ultrasound. Computerized features corresponding to ultrasound BI-RADs categories were designed and tested using a database of 283 pathology-proven benign and malignant lesions. Features were selected based on classification performance using a "bottom-up" approach for different machine learning methods, including decision tree, artificial neural network, random forest and support vector machine. Using 10-fold cross-validation on the database of 283 cases, the highest area under the receiver operating characteristic (ROC) curve (AUC) was 0.84 from a support vector machine with 77.7% overall accuracy; the highest overall accuracy, 78.5%, was from a random forest with the AUC 0.83. Lesion margin and orientation were optimum features common to all of the different machine learning methods. These features can be used in CAD systems to help distinguish benign from worrisome lesions. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. All rights reserved.

  2. Evaluation of limited sampling models for prediction of oral midazolam AUC for CYP3A phenotyping and drug interaction studies.

    Science.gov (United States)

    Mueller, Silke C; Drewelow, Bernd

    2013-05-01

    The area under the concentration-time curve (AUC) after oral midazolam administration is commonly used for cytochrome P450 (CYP) 3A phenotyping studies. The aim of this investigation was to evaluate a limited sampling strategy for the prediction of AUC with oral midazolam. A total of 288 concentration-time profiles from 123 healthy volunteers who participated in four previously performed drug interaction studies with intense sampling after a single oral dose of 7.5 mg midazolam were available for evaluation. Of these, 45 profiles served for model building, which was performed by stepwise multiple linear regression, and the remaining 243 datasets served for validation. Mean prediction error (MPE), mean absolute error (MAE) and root mean squared error (RMSE) were calculated to determine bias and precision The one- to four-sampling point models with the best coefficient of correlation were the one-sampling point model (8 h; r (2) = 0.84), the two-sampling point model (0.5 and 8 h; r (2) = 0.93), the three-sampling point model (0.5, 2, and 8 h; r (2) = 0.96), and the four-sampling point model (0.5,1, 2, and 8 h; r (2) = 0.97). However, the one- and two-sampling point models were unable to predict the midazolam AUC due to unacceptable bias and precision. Only the four-sampling point model predicted the very low and very high midazolam AUC of the validation dataset with acceptable precision and bias. The four-sampling point model was also able to predict the geometric mean ratio of the treatment phase over the baseline (with 90 % confidence interval) results of three drug interaction studies in the categories of strong, moderate, and mild induction, as well as no interaction. A four-sampling point limited sampling strategy to predict the oral midazolam AUC for CYP3A phenotyping is proposed. The one-, two- and three-sampling point models were not able to predict midazolam AUC accurately.

  3. Carbonated water (CW) process waste reuse for ammonium-uranyl-carbonate (AUC) production and its gains on the environmental, economic and social aspects

    Energy Technology Data Exchange (ETDEWEB)

    Carnaval, Joao Paulo R.; Santos, Rafael D. dos; Barbosa, Rodrigo A.; Lauer, Sergio, E-mail: joaocarnaval@inb.gov.br, E-mail: rafaelsantos@inb.gov.br, E-mail: rodrigobarbosa@inb.gov.br, E-mail: lauer@inb.gov.br [Industias Nucleares do Brasil S.A. (INB), Resende, RJ (Brazil)

    2013-07-01

    In the INB nuclear fuel cycle, the pellets production is based on UO{sub 2} powder made by AUC (Ammonium-Uranyl-Carbonate) route. AUC formation occurs by fluidising of UF{sub 6}, NH{sub 3} and CO{sub 2} in a vase containing usually pure water, and this exothermal reaction has AUC as direct product. The mass formed is filtered, washed with CW, washed again with methano solution, dried with air and conducted to the fluidized bed furnace, to be converted to UO{sub 2} powder. At this point, the dried AUC decompounds to UO{sub 3}, NH{sub 3} and C0{sub 2}, these 2 gases are absorbed at the gases washer, formin go the carbonated water (CW), whit is basically a (NH{sub 4}){sub 2}CO{sub 3} solution. The UO{sub 2+x} is reduced and stabilized to UO{sub 2} powder, which is conducted to pellets production. During the process, a considerable amount of this aqueous waste is generated and goes for effluent treatment. After that, the solution is sent for spray-dryer for power formation, and stock. This treatment demands equipment, energy and time, representing considerable costs of the company beyond the human risks involved on the drying step. The purpose of this work is to present a study of the carbonated water use as substitute of pure water in the AUC formation step. At this point, tests were made varying the CW loads for the AUC precipitation, and the control was made by the UO{sub 2} powder properties. The carbonated water used for AUC precipitation has been tested at several levels and the results has demonstrated full viability to become a definitive process step (INB, Resende site). It has been demonstrated the great resources economy caused by the waste reuse and the guarantee product quality. This represents such an environmental gain and also economic and social aspects got improved. (author)

  4. Artificial neural network approach to predict surgical site infection after free-flap reconstruction in patients receiving surgery for head and neck cancer.

    Science.gov (United States)

    Kuo, Pao-Jen; Wu, Shao-Chun; Chien, Peng-Chen; Chang, Shu-Shya; Rau, Cheng-Shyuan; Tai, Hsueh-Ling; Peng, Shu-Hui; Lin, Yi-Chun; Chen, Yi-Chun; Hsieh, Hsiao-Yun; Hsieh, Ching-Hua

    2018-03-02

    The aim of this study was to develop an effective surgical site infection (SSI) prediction model in patients receiving free-flap reconstruction after surgery for head and neck cancer using artificial neural network (ANN), and to compare its predictive power with that of conventional logistic regression (LR). There were 1,836 patients with 1,854 free-flap reconstructions and 438 postoperative SSIs in the dataset for analysis. They were randomly assigned tin ratio of 7:3 into a training set and a test set. Based on comprehensive characteristics of patients and diseases in the absence or presence of operative data, prediction of SSI was performed at two time points (pre-operatively and post-operatively) with a feed-forward ANN and the LR models. In addition to the calculated accuracy, sensitivity, and specificity, the predictive performance of ANN and LR were assessed based on area under the curve (AUC) measures of receiver operator characteristic curves and Brier score. ANN had a significantly higher AUC (0.892) of post-operative prediction and AUC (0.808) of pre-operative prediction than LR (both P <0.0001). In addition, there was significant higher AUC of post-operative prediction than pre-operative prediction by ANN (p<0.0001). With the highest AUC and the lowest Brier score (0.090), the post-operative prediction by ANN had the highest overall predictive performance. The post-operative prediction by ANN had the highest overall performance in predicting SSI after free-flap reconstruction in patients receiving surgery for head and neck cancer.

  5. Diagnostic test accuracy of nutritional tools used to identify undernutrition in patients with colorectal cancer: a systematic review.

    Science.gov (United States)

    Håkonsen, Sasja Jul; Pedersen, Preben Ulrich; Bath-Hextall, Fiona; Kirkpatrick, Pamela

    2015-05-15

    and negative predictive values. In addition, the positive likelihood ratio (sensitivity/ [1 - specificity]) and negative likelihood ratio (1 - sensitivity)/ specificity), were also calculated and presented in this review to provide information about the likelihood that a given test result would be expected when the target condition is present compared with the likelihood that the same result would be expected when the condition is absent. Not all trials reported true positive, true negative, false positive and false negative rates, therefore these rates were calculated based on the data in the published papers. A two-by-two truth table was reconstructed for each study, and sensitivity, specificity, positive predictive value, negative predictive value positive likelihood ratio and negative likelihood ratio were calculated for each study. A summary receiver operator characteristics curve was constructed to determine the relationship between sensitivity and specificity, and the area under the summary receiver operator characteristics curve which measured the usefulness of a test was calculated. Meta-analysis was not considered appropriate, therefore data was synthesized in a narrative summary. 1. One study evaluated the Malnutrition Screening Tool against the reference standard Patient-Generated Subjective Global Assessment. The sensitivity was 56% and the specificity 84%. The positive likelihood ratio was 3.100, negative likelihood ratio was 0.59, the diagnostic odds ratio (CI 95%) was 5.20 (1.09-24.90) and the Area Under the Curve (AUC) represents only a poor to fair diagnostic test accuracy. A total of two studies evaluated the diagnostic accuracy of Malnutrition Universal Screening Tool (MUST) (index test) compared to both Subjective Global Assessment (SGA) (reference standard) and PG-SGA (reference standard) in patients with colorectal cancer. In MUST vs SGA the sensitivity of the tool was 96%, specificity was 75%, LR+ 3.826, LR- 0.058, diagnostic OR (CI 95%) 66

  6. A new mathematical approach for the estimation of the AUC and its variability under different experimental designs in preclinical studies.

    Science.gov (United States)

    Navarro-Fontestad, Carmen; González-Álvarez, Isabel; Fernández-Teruel, Carlos; Bermejo, Marival; Casabó, Vicente Germán

    2012-01-01

    The aim of the present work was to develop a new mathematical method for estimating the area under the curve (AUC) and its variability that could be applied in different preclinical experimental designs and amenable to be implemented in standard calculation worksheets. In order to assess the usefulness of the new approach, different experimental scenarios were studied and the results were compared with those obtained with commonly used software: WinNonlin® and Phoenix WinNonlin®. The results do not show statistical differences among the AUC values obtained by both procedures, but the new method appears to be a better estimator of the AUC standard error, measured as the coverage of 95% confidence interval. In this way, the new proposed method demonstrates to be as useful as WinNonlin® software when it was applicable. Copyright © 2011 John Wiley & Sons, Ltd.

  7. Lowest cost due to highest productivity and highest quality

    Science.gov (United States)

    Wenk, Daniel

    2003-03-01

    Since global purchasing in the automotive industry has been taken up all around the world there is one main key factor that makes a TB-supplier today successful: Producing highest quality at lowest cost. The fact that Tailored Blanks, which today may reach up to 1/3 of a car body weight, are purchased on the free market but from different steel suppliers, especially in Europe and NAFTA, the philosophy on OEM side has been changing gradually towards tough evaluation criteria. "No risk at the stamping side" calls for top quality Tailored- or Tubular Blank products. Outsourcing Tailored Blanks has been starting in Japan but up to now without any quality request from the OEM side like ISO 13919-1B (welding quality standard in Europe and USA). Increased competition will automatically push the quality level and the ongoing approach to combine high strength steel with Tailored- and Tubular Blanks will ask for even more reliable system concepts which enables to weld narrow seams at highest speed. Beside producing quality, which is the key to reduce one of the most important cost driver "material scrap," in-line quality systems with true and reliable evaluation is going to be a "must" on all weld systems. Traceability of all process related data submitted to interfaces according to customer request in combination with ghost-shift-operation of TB systems are tomorrow's state-of-the-art solutions of Tailored Blank-facilities.

  8. Can machine-learning improve cardiovascular risk prediction using routine clinical data?

    Science.gov (United States)

    Kai, Joe; Garibaldi, Jonathan M.; Qureshi, Nadeem

    2017-01-01

    Background Current approaches to predict cardiovascular risk fail to identify many people who would benefit from preventive treatment, while others receive unnecessary intervention. Machine-learning offers opportunity to improve accuracy by exploiting complex interactions between risk factors. We assessed whether machine-learning can improve cardiovascular risk prediction. Methods Prospective cohort study using routine clinical data of 378,256 patients from UK family practices, free from cardiovascular disease at outset. Four machine-learning algorithms (random forest, logistic regression, gradient boosting machines, neural networks) were compared to an established algorithm (American College of Cardiology guidelines) to predict first cardiovascular event over 10-years. Predictive accuracy was assessed by area under the ‘receiver operating curve’ (AUC); and sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) to predict 7.5% cardiovascular risk (threshold for initiating statins). Findings 24,970 incident cardiovascular events (6.6%) occurred. Compared to the established risk prediction algorithm (AUC 0.728, 95% CI 0.723–0.735), machine-learning algorithms improved prediction: random forest +1.7% (AUC 0.745, 95% CI 0.739–0.750), logistic regression +3.2% (AUC 0.760, 95% CI 0.755–0.766), gradient boosting +3.3% (AUC 0.761, 95% CI 0.755–0.766), neural networks +3.6% (AUC 0.764, 95% CI 0.759–0.769). The highest achieving (neural networks) algorithm predicted 4,998/7,404 cases (sensitivity 67.5%, PPV 18.4%) and 53,458/75,585 non-cases (specificity 70.7%, NPV 95.7%), correctly predicting 355 (+7.6%) more patients who developed cardiovascular disease compared to the established algorithm. Conclusions Machine-learning significantly improves accuracy of cardiovascular risk prediction, increasing the number of patients identified who could benefit from preventive treatment, while avoiding unnecessary treatment of others

  9. Best single time point correlations with AUC for cyclosporine and tacrolimus in HIV-infected kidney and liver transplant recipients.

    Science.gov (United States)

    Frassetto, Lynda A; Tan-Tam, Clara C; Barin, Burc; Browne, Matt; Wolfe, Alan R; Stock, Peter G; Roland, Michelle; Benet, Leslie Z

    2014-03-27

    Interactions between antiretrovirals (ARVs) and transplant immunosuppressant agents (IS) among HIV-infected transplant recipients may lead to lack of efficacy or toxicity. In transplant recipients not infected with HIV, tacrolimus (TAC) trough levels (C0) or cyclosporine (CsA) drawn at C0 or 2 hours after dosing (C2) correlate with drug exposure (area under the curve [AUC]/dose) and outcomes. Because of ARV-IS interactions in HIV-infected individuals, and the high rate of rejection in these subjects, this study investigated the correlations between IS concentrations and exposure to determine the best method to monitor immunosuppressant levels. This study prospectively studied 50 HIV-infected transplant recipients undergoing kidney or liver transplantation evaluating the pharmacokinetics of the IS in 150 studies over time after transplantation (weeks 2 to 4, 12, 28, 52, and 104). IS levels were measured with liquid chromatography-tandem mass spectrometry and AUC calculated using WinNonlin 9.0. Correlation analyses were run on SAS 9.2. CsA concentration at C4 correlated better with AUC than C0 or C2, and over time TAC concentration correlated better at C0 or C2. It is suggested that C0 is acceptable for TAC monitoring, but poor predictability will occur at C0 with CsA. The low correlation of C0 with CsA AUC could be responsible for the higher rejection rates on CsA that has been reported in these subjects.

  10. How to interpret a small increase in AUC with an additional risk prediction marker: decision analysis comes through.

    Science.gov (United States)

    Baker, Stuart G; Schuit, Ewoud; Steyerberg, Ewout W; Pencina, Michael J; Vickers, Andrew; Vickers, Andew; Moons, Karel G M; Mol, Ben W J; Lindeman, Karen S

    2014-09-28

    An important question in the evaluation of an additional risk prediction marker is how to interpret a small increase in the area under the receiver operating characteristic curve (AUC). Many researchers believe that a change in AUC is a poor metric because it increases only slightly with the addition of a marker with a large odds ratio. Because it is not possible on purely statistical grounds to choose between the odds ratio and AUC, we invoke decision analysis, which incorporates costs and benefits. For example, a timely estimate of the risk of later non-elective operative delivery can help a woman in labor decide if she wants an early elective cesarean section to avoid greater complications from possible later non-elective operative delivery. A basic risk prediction model for later non-elective operative delivery involves only antepartum markers. Because adding intrapartum markers to this risk prediction model increases AUC by 0.02, we questioned whether this small improvement is worthwhile. A key decision-analytic quantity is the risk threshold, here the risk of later non-elective operative delivery at which a patient would be indifferent between an early elective cesarean section and usual care. For a range of risk thresholds, we found that an increase in the net benefit of risk prediction requires collecting intrapartum marker data on 68 to 124 women for every correct prediction of later non-elective operative delivery. Because data collection is non-invasive, this test tradeoff of 68 to 124 is clinically acceptable, indicating the value of adding intrapartum markers to the risk prediction model. Copyright © 2014 John Wiley & Sons, Ltd.

  11. Apparent diffusion coefficient in the analysis of prostate cancer: determination of optimal b-value pair to differentiate normal from malignant tissue.

    Science.gov (United States)

    Adubeiro, Nuno; Nogueira, Maria Luísa; Nunes, Rita G; Ferreira, Hugo Alexandre; Ribeiro, Eduardo; La Fuente, José Maria Ferreira

    Determining optimal b-value pair for differentiation between normal and prostate cancer (PCa) tissues. Forty-three patients with diagnosis or PCa symptoms were included. Apparent diffusion coefficient (ADC) was estimated using minimum and maximum b-values of 0, 50, 100, 150, 200, 500s/mm2 and 500, 800, 1100, 1400, 1700 and 2000s/mm2, respectively. Diagnostic performances were evaluated when Area-under-the-curve (AUC)>95%. 15 of the 35 b-values pair surpassed this AUC threshold. The pair (50, 2000s/mm2) provided the highest AUC (96%) with ADC cutoff 0.89×10- 3 mm 2 /s, sensitivity 95.5%, specificity 93.2% and accuracy 94.4%. The best b-value pair was b=50, 2000s/mm2. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Assessment of early-stage optic nerve invasion in retinoblastoma using high-resolution 1.5 Tesla MRI with surface coils: a multicentre, prospective accuracy study with histopathological correlation

    Energy Technology Data Exchange (ETDEWEB)

    Brisse, Herve J. [Institut Curie, Department of Radiology, Paris (France); Institut CURIE, Imaging Department, Paris (France); Graaf, Pim de; Rodjan, Firazia; Jong, Marcus C. de; Castelijns, Jonas A. [VU University Medical Center, Department of Radiology, Amsterdam (Netherlands); Galluzzi, Paolo [Neuroimaging and Neurointerventional Unit (NINT) Azienda Ospedaliera e Universitaria Senese, Siena (Italy); Cosker, Kristel; Savignoni, Alexia [Institut Curie, Department of Biostatistics, Paris (France); Maeder, Philippe [Centre Hospitalier Universitaire Vaudois (CHUV) and University of Lausanne, Department of Radiology, Lausanne (Switzerland); Goericke, Sophia [University Hospital Essen, Institute of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Aerts, Isabelle [Institut Curie, Department of Pediatric Oncology, Paris (France); Desjardins, Laurence [Institut Curie, Department of Ophthalmology, Paris (France); Moll, Annette C. [VU University Medical Center, Department of Ophthalmology, Amsterdam (Netherlands); Hadjistilianou, Theodora [Azienda Ospedaliera Universitaria Senese, Department of Ophthalmology, Siena (Italy); Toti, Paolo [University of Siena, Department of Medical Biotechnologies, Pathology Unit, Siena (Italy); Valk, Paul van der [VU University Medical Center, Department of Pathology, Amsterdam (Netherlands); Sastre-Garau, Xavier [Institut Curie, Department of Biopathology, Paris (France); Collaboration: European Retinoblastoma Imaging Collaboration (ERIC)

    2015-05-01

    To assess the accuracy of high-resolution (HR) magnetic resonance imaging (MRI) in diagnosing early-stage optic nerve (ON) invasion in a retinoblastoma cohort. This IRB-approved, prospective multicenter study included 95 patients (55 boys, 40 girls; mean age, 29 months). 1.5-T MRI was performed using surface coils before enucleation, including spin-echo unenhanced and contrast-enhanced (CE) T1-weighted sequences (slice thickness, 2 mm; pixel size <0.3 x 0.3 mm{sup 2}). Images were read by five neuroradiologists blinded to histopathologic findings. ROC curves were constructed with AUC assessment using a bootstrap method. Histopathology identified 41 eyes without ON invasion and 25 with prelaminar, 18 with intralaminar and 12 with postlaminar invasion. All but one were postoperatively classified as stage I by the International Retinoblastoma Staging System. The accuracy of CE-T1 sequences in identifying ON invasion was limited (AUC = 0.64; 95 % CI, 0.55 - 0.72) and not confirmed for postlaminar invasion diagnosis (AUC = 0.64; 95 % CI, 0.47 - 0.82); high specificities (range, 0.64 - 1) and negative predictive values (range, 0.81 - 0.97) were confirmed. HR-MRI with surface coils is recommended to appropriately select retinoblastoma patients eligible for primary enucleation without the risk of IRSS stage II but cannot substitute for pathology in differentiating the first degrees of ON invasion. (orig.)

  13. Proposal for a Revised Programme of Studies at the Faculty of Engineering, Ondo State University Using the Pedagogical Model at AUC as Reference

    DEFF Research Database (Denmark)

    Jørgensen, Mogens B.; Borch, Ole; Esan, A. A.

    by AUC Staff. It will, of course, remain a requirement that minimum requirements laid down by the National Universities Commission are met. This was taken into account when preparing the proposal. The report is seen as a first important step towards the introduction of the AUC pedagogical model at OSUA...

  14. An Approach for Predicting Essential Genes Using Multiple Homology Mapping and Machine Learning Algorithms.

    Science.gov (United States)

    Hua, Hong-Li; Zhang, Fa-Zhan; Labena, Abraham Alemayehu; Dong, Chuan; Jin, Yan-Ting; Guo, Feng-Biao

    Investigation of essential genes is significant to comprehend the minimal gene sets of cell and discover potential drug targets. In this study, a novel approach based on multiple homology mapping and machine learning method was introduced to predict essential genes. We focused on 25 bacteria which have characterized essential genes. The predictions yielded the highest area under receiver operating characteristic (ROC) curve (AUC) of 0.9716 through tenfold cross-validation test. Proper features were utilized to construct models to make predictions in distantly related bacteria. The accuracy of predictions was evaluated via the consistency of predictions and known essential genes of target species. The highest AUC of 0.9552 and average AUC of 0.8314 were achieved when making predictions across organisms. An independent dataset from Synechococcus elongatus , which was released recently, was obtained for further assessment of the performance of our model. The AUC score of predictions is 0.7855, which is higher than other methods. This research presents that features obtained by homology mapping uniquely can achieve quite great or even better results than those integrated features. Meanwhile, the work indicates that machine learning-based method can assign more efficient weight coefficients than using empirical formula based on biological knowledge.

  15. Criterion validity of the Short Mood and Feelings Questionnaire and one- and two-item depression screens in young adolescents

    Directory of Open Access Journals (Sweden)

    McCauley Elizabeth

    2010-02-01

    Full Text Available Abstract Background The use of short screening questionnaires may be a promising option for identifying children at risk for depression in a community setting. The objective of this study was to assess the validity of the Short Mood and Feelings Questionnaire (SMFQ and one- and two-item screening instruments for depressive disorders in a school-based sample of young adolescents. Methods Participants were 521 sixth-grade students attending public middle schools. Child and parent versions of the SMFQ were administered to evaluate the child's depressive symptoms. The presence of any depressive disorder during the previous month was assessed using the Diagnostic Interview Schedule for Children (DISC as the criterion standard. First, we assessed the diagnostic accuracy of child, parent, and combined scores of the full 13-item SMFQ by calculating the area under the receiver operating characteristic curve (AUC, sensitivity and specificity. The same approach was then used to evaluate the accuracy of a two-item scale consisting of only depressed mood and anhedonia items, and a single depressed mood item. Results The combined child + parent SMFQ score showed the highest accuracy (AUC = 0.86. Diagnostic accuracy was lower for child (AUC = 0.73 and parent (AUC = 0.74 SMFQ versions. Corresponding versions of one- and two-item screens had lower AUC estimates, but the combined versions of the brief screens each still showed moderate accuracy. Furthermore, child and combined versions of the two-item screen demonstrated higher sensitivity (although lower specificity than either the one-item screen or the full SMFQ. Conclusions Under conditions where parents accompany children to screening settings (e.g. primary care, use of a child + parent version of the SMFQ is recommended. However, when parents are not available, and the cost of a false positive result is minimal, then a one- or two-item screen may be useful for initial identification of at-risk youth.

  16. RDT accuracy based on age group in hypoendemic malaria

    Science.gov (United States)

    Siahaan, L.; Panggabean, M.; Panggabean, Y. C.

    2018-03-01

    Malaria is still one of the problem of community health in Sumatera. This study was carried out to compare RDT accuracy in some groups of age in hypoendemic malaria. The microscopy test was investigated by 3% Giemsa Staining and examined by a trained laboratory technician. RDT was carried out by using Monotes Test Drive. The accuracy of RDT diagnostic was commonly significant in all groups of age, exceptin thegroup of age > 65 years old (p=0.393). The highest sensitivity of RDT was commonly inagroup of age ≤ 5 years old and decreased in the older group of age. Otherwise, the lowest specificity was found in agroup of age ≤ 5 years old and the highest in agroup of age 6-15 years old.The highest PPV and NPV was found inagroup of age 16-65 years old and ≤ 5 years old, respectively. The highest of parasite density was found in a group of age ≤ 5 years old (644.4±494.5parasite/μl) and the lowest in agroup of age > 65 years (400±490.71parasite/μl). The accurate diagnosis of RDT reduces by increasing of age.

  17. A Novel Reporting System to Improve Accuracy in Appendicitis Imaging

    Science.gov (United States)

    Godwin, Benjamin D.; Drake, Frederick T.; Simianu, Vlad V.; Shriki, Jabi E.; Hippe, Daniel S.; Dighe, Manjiri; Bastawrous, Sarah; Cuevas, Carlos; Flum, David; Bhargava, Puneet

    2015-01-01

    OBJECTIVE The purpose of this study was to ascertain if standardized radiologic reporting for appendicitis imaging increases diagnostic accuracy. MATERIALS AND METHODS We developed a standardized appendicitis reporting system that includes objective imaging findings common in appendicitis and a certainty score ranging from 1 (definitely not appendicitis) through 5 (definitely appendicitis). Four radiologists retrospectively reviewed the preoperative CT scans of 96 appendectomy patients using our reporting system. The presence of appendicitis-specific imaging findings and certainty scores were compared with final pathology. These comparisons were summarized using odds ratios (ORs) and the AUC. RESULTS The appendix was visualized on CT in 89 patients, of whom 71 (80%) had pathologically proven appendicitis. Imaging findings associated with appendicitis included appendiceal diameter (odds ratio [OR] = 14 [> 10 vs appendicitis. In this initially indeterminate group, using the standardized reporting system, radiologists assigned higher certainty scores (4 or 5) in 21 of the 28 patients with appendicitis (75%) and lower scores (1 or 2) in five of the seven patients without appendicitis (71%) (AUC = 0.90; p = 0.001). CONCLUSION Standardized reporting and grading of objective imaging findings correlated well with postoperative pathology and may decrease the number of CT findings reported as indeterminate for appendicitis. Prospective evaluation of this reporting system on a cohort of patients with clinically suspected appendicitis is currently under way. PMID:26001230

  18. Chronotropic response to vasodilator-stress in patients submitted to myocardial perfusion imaging: impact on the accuracy in detecting coronary stenosis

    International Nuclear Information System (INIS)

    Gimelli, Alessia; Coceani, Michele; Quaranta, Angela; Emdin, Michele; Liga, Riccardo; Marzullo, Paolo

    2015-01-01

    A lower heart rate response (HRR) during vasodilator MPI has been shown to have a relevant adverse prognostic impact. We sought to evaluate the interaction among individual HRR to vasodilator stress and myocardial perfusion imaging (MPI) accuracy in patients with suspected ischemic heart disease (IHD). One hundred and sixty-five consecutive patients were submitted to vasodilator-stress MPI on a cardiac camera equipped with cadmium-zinc-thelluride detectors and coronary angiography. A coronary stenosis >70 % was considered significant. In every patient, the summed difference score (SDS) was computed from MPI images. Patients were categorized according to the tertiles of the distribution of individual HRR during dipyridamole: ''Group 1'' (HRR < 8 bpm; lowest tertile); ''Group 2'' (8 ≤ HRR ≤ 12 bpm; middle tertile); ''Group 3'' (HRR >12 bpm; highest tertile). Significant coronary artery disease (CAD) was present in 102 (62 %) patients. In the overall population, MPI showed a significant accuracy (AUC: 0.81, 95 % CI 0.74-0.86; p < 0.001) in unmasking the presence of significant coronary stenosis. Interestingly, in patients with a blunted HRR during dipyridamole (''Group 1'') MPI showed a significantly lower sensitivity (68 %) in detecting CAD than in those with a higher HRR (''Group 3'') (91 %, p = 0.007), despite a preserved specificity (76 % vs 77 %, P=NS). Similarly, the correlation among CAD extent and post-stress LV functional stunning was limited to ''Group 3'' patients, while it disappeared in those with blunted HRR. In patients with suspected IHD, MPI sensitivity is strongly influenced by the magnitude of patient heart rate increase to the pharmacologic stressor, suggesting an interaction among blunted HRR and lower accuracy in unmasking CAD. (orig.)

  19. Chronotropic response to vasodilator-stress in patients submitted to myocardial perfusion imaging: impact on the accuracy in detecting coronary stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Gimelli, Alessia; Coceani, Michele; Quaranta, Angela; Emdin, Michele [Fondazione Toscana Gabriele Monasterio, Pisa (Italy); Liga, Riccardo [University Hospital of Pisa, Cardio-Thoracic and Vascular Department, Pisa (Italy); Marzullo, Paolo [Fondazione Toscana Gabriele Monasterio, Pisa (Italy); CNR, Institute of Clinical Physiology, Pisa (Italy)

    2015-11-15

    A lower heart rate response (HRR) during vasodilator MPI has been shown to have a relevant adverse prognostic impact. We sought to evaluate the interaction among individual HRR to vasodilator stress and myocardial perfusion imaging (MPI) accuracy in patients with suspected ischemic heart disease (IHD). One hundred and sixty-five consecutive patients were submitted to vasodilator-stress MPI on a cardiac camera equipped with cadmium-zinc-thelluride detectors and coronary angiography. A coronary stenosis >70 % was considered significant. In every patient, the summed difference score (SDS) was computed from MPI images. Patients were categorized according to the tertiles of the distribution of individual HRR during dipyridamole: ''Group 1'' (HRR < 8 bpm; lowest tertile); ''Group 2'' (8 ≤ HRR ≤ 12 bpm; middle tertile); ''Group 3'' (HRR >12 bpm; highest tertile). Significant coronary artery disease (CAD) was present in 102 (62 %) patients. In the overall population, MPI showed a significant accuracy (AUC: 0.81, 95 % CI 0.74-0.86; p < 0.001) in unmasking the presence of significant coronary stenosis. Interestingly, in patients with a blunted HRR during dipyridamole (''Group 1'') MPI showed a significantly lower sensitivity (68 %) in detecting CAD than in those with a higher HRR (''Group 3'') (91 %, p = 0.007), despite a preserved specificity (76 % vs 77 %, P=NS). Similarly, the correlation among CAD extent and post-stress LV functional stunning was limited to ''Group 3'' patients, while it disappeared in those with blunted HRR. In patients with suspected IHD, MPI sensitivity is strongly influenced by the magnitude of patient heart rate increase to the pharmacologic stressor, suggesting an interaction among blunted HRR and lower accuracy in unmasking CAD. (orig.)

  20. MUSCLE: multiple sequence alignment with high accuracy and high throughput.

    Science.gov (United States)

    Edgar, Robert C

    2004-01-01

    We describe MUSCLE, a new computer program for creating multiple alignments of protein sequences. Elements of the algorithm include fast distance estimation using kmer counting, progressive alignment using a new profile function we call the log-expectation score, and refinement using tree-dependent restricted partitioning. The speed and accuracy of MUSCLE are compared with T-Coffee, MAFFT and CLUSTALW on four test sets of reference alignments: BAliBASE, SABmark, SMART and a new benchmark, PREFAB. MUSCLE achieves the highest, or joint highest, rank in accuracy on each of these sets. Without refinement, MUSCLE achieves average accuracy statistically indistinguishable from T-Coffee and MAFFT, and is the fastest of the tested methods for large numbers of sequences, aligning 5000 sequences of average length 350 in 7 min on a current desktop computer. The MUSCLE program, source code and PREFAB test data are freely available at http://www.drive5. com/muscle.

  1. A Systematic Review and Meta-analysis of the Diagnostic Accuracy of Prostate Health Index and 4-Kallikrein Panel Score in Predicting Overall and High-grade Prostate Cancer.

    Science.gov (United States)

    Russo, Giorgio Ivan; Regis, Federica; Castelli, Tommaso; Favilla, Vincenzo; Privitera, Salvatore; Giardina, Raimondo; Cimino, Sebastiano; Morgia, Giuseppe

    2017-08-01

    Markers for prostate cancer (PCa) have progressed over recent years. In particular, the prostate health index (PHI) and the 4-kallikrein (4K) panel have been demonstrated to improve the diagnosis of PCa. We aimed to review the diagnostic accuracy of PHI and the 4K panel for PCa detection. We performed a systematic literature search of PubMed, EMBASE, Cochrane, and Academic One File databases until July 2016. We included diagnostic accuracy studies that used PHI or 4K panel for the diagnosis of PCa or high-grade PCa. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Twenty-eight studies including 16,762 patients have been included for the analysis. The pooled data showed a sensitivity of 0.89 and 0.74 for PHI and 4K panel, respectively, for PCa detection and a pooled specificity of 0.34 and 0.60 for PHI and 4K panel, respectively. The derived area under the curve (AUC) from the hierarchical summary receiver operating characteristic (HSROC) showed an accuracy of 0.76 and 0.72 for PHI and 4K panel respectively. For high-grade PCa detection, the pooled sensitivity was 0.93 and 0.87 for PHI and 4K panel, respectively, whereas the pooled specificity was 0.34 and 0.61 for PHI and 4K panel, respectively. The derived AUC from the HSROC showed an accuracy of 0.82 and 0.81 for PHI and 4K panel, respectively. Both PHI and the 4K panel provided good diagnostic accuracy in detecting overall and high-grade PCa. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Intranasal Pharmacokinetic Data for Triptans Such as Sumatriptan and Zolmitriptan Can Render Area Under the Curve (AUC) Predictions for the Oral Route: Strategy Development and Application

    DEFF Research Database (Denmark)

    Srinivas, Nuggehally R.; Syed, Muzeeb

    2016-01-01

    Limited pharmacokinetic sampling strategy may be useful for predicting the area under the curve (AUC) for triptans and may have clinical utility as a prospective tool for prediction. Using appropriate intranasal pharmacokinetic data, a Cmax vs. AUC relationship was established by linear regression...... models for sumatriptan and zolmitriptan. The predictions of the AUC values were performed using published mean/median Cmax data and appropriate regression lines. The quotient of observed and predicted values rendered fold-difference calculation. The mean absolute error (MAE), mean positive error (MPE......), mean negative error (MNE), root mean square error (RMSE), correlation coefficient (r), and the goodness of the AUC fold prediction were used to evaluate the two triptans. Also, data from the mean concentration profiles at time points of 1 hour (sumatriptan) and 3 hours (zolmitriptan) were used...

  3. Dosing algorithm to target a predefined AUC in patients with primary central nervous system lymphoma receiving high dose methotrexate.

    Science.gov (United States)

    Joerger, Markus; Ferreri, Andrés J M; Krähenbühl, Stephan; Schellens, Jan H M; Cerny, Thomas; Zucca, Emanuele; Huitema, Alwin D R

    2012-02-01

    There is no consensus regarding optimal dosing of high dose methotrexate (HDMTX) in patients with primary CNS lymphoma. Our aim was to develop a convenient dosing algorithm to target AUC(MTX) in the range between 1000 and 1100 µmol l(-1) h. A population covariate model from a pooled dataset of 131 patients receiving HDMTX was used to simulate concentration-time curves of 10,000 patients and test the efficacy of a dosing algorithm based on 24 h MTX plasma concentrations to target the prespecified AUC(MTX) . These data simulations included interindividual, interoccasion and residual unidentified variability. Patients received a total of four simulated cycles of HDMTX and adjusted MTX dosages were given for cycles two to four. The dosing algorithm proposes MTX dose adaptations ranging from +75% in patients with MTX C(24) 12 µmol l(-1). The proposed dosing algorithm resulted in a marked improvement of the proportion of patients within the AUC(MTX) target between 1000 and 1100 µmol l(-1) h (11% with standard MTX dose, 35% with the adjusted dose) and a marked reduction of the interindividual variability of MTX exposure. A simple and practical dosing algorithm for HDMTX has been developed based on MTX 24 h plasma concentrations, and its potential efficacy in improving the proportion of patients within a prespecified target AUC(MTX) and reducing the interindividual variability of MTX exposure has been shown by data simulations. The clinical benefit of this dosing algorithm should be assessed in patients with primary central nervous system lymphoma (PCNSL). © 2011 The Authors. British Journal of Clinical Pharmacology © 2011 The British Pharmacological Society.

  4. Rocker: Open source, easy-to-use tool for AUC and enrichment calculations and ROC visualization.

    Science.gov (United States)

    Lätti, Sakari; Niinivehmas, Sanna; Pentikäinen, Olli T

    2016-01-01

    Receiver operating characteristics (ROC) curve with the calculation of area under curve (AUC) is a useful tool to evaluate the performance of biomedical and chemoinformatics data. For example, in virtual drug screening ROC curves are very often used to visualize the efficiency of the used application to separate active ligands from inactive molecules. Unfortunately, most of the available tools for ROC analysis are implemented into commercially available software packages, or are plugins in statistical software, which are not always the easiest to use. Here, we present Rocker, a simple ROC curve visualization tool that can be used for the generation of publication quality images. Rocker also includes an automatic calculation of the AUC for the ROC curve and Boltzmann-enhanced discrimination of ROC (BEDROC). Furthermore, in virtual screening campaigns it is often important to understand the early enrichment of active ligand identification, for this Rocker offers automated calculation routine. To enable further development of Rocker, it is freely available (MIT-GPL license) for use and modifications from our web-site (http://www.jyu.fi/rocker).

  5. On the Derivation of Highest-Order Compact Finite Difference Schemes for the One- and Two-Dimensional Poisson Equation with Dirichlet Boundary Conditions

    KAUST Repository

    Settle, Sean O.; Douglas, Craig C.; Kim, Imbunm; Sheen, Dongwoo

    2013-01-01

    - and two-dimensional Poisson equation on uniform, quasi-uniform, and nonuniform face-to-face hyperrectangular grids and directly prove the existence or nonexistence of their highest-order local accuracies. Our derivations are unique in that we do not make

  6. Diagnostic accuracy of the Barr and Blethyn radiological scoring systems for childhood constipation assessed using colonic transit time as the gold standard

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, Claire R.; Wylie, Anna B.Z.; Adams, Charlotte [Royal Victoria Infirmary, Department of Paediatric Surgery, Newcastle upon Tyne (United Kingdom); Lee, Richard E. [Royal Victoria Infirmary, Department of Radiology, Newcastle upon Tyne (United Kingdom); Jaffray, Bruce [University of Newcastle upon Tyne, School of Clinical Medical Sciences (Child Health), Sir James Spence Institute, Newcastle upon Tyne (United Kingdom)

    2009-07-15

    Constipation is a common childhood symptom and abdominal radiography is advocated in diagnosis and management. To assess the reproducibility and diagnostic accuracy of the Barr and Blethyn systems for quantifying constipation on abdominal radiographs in children. Radiographs were scored by three observers of increasing radiological experience (student, junior doctor, consultant). Abdominal radiographs produced during measurement of colonic transit time (CTT) were classified as constipated or normal based on the value of the transit time, and were scored using both systems by observers blinded to the CTT. Abdominal radiographs obtained in children for reasons other than constipation were classed as normal and similarly scored. Reproducibility was measured using the kappa statistic. Diagnostic accuracy was measured using the area under the curve (AUC) for the receiver operator characteristic (ROC) curve. Using either system, scores were higher for constipated children (P<0.01). The consultant produced higher scores than the other observers (P<0.01). Interobserver reproducibility was moderate with the best kappa value only 0.48. The best correlation between score and CTT was 0.51 (junior doctor scores). Diagnostic accuracy of the scores was only moderate, with the largest AUC for a ROC curve of 0.84 for the consultant using the Barr score. Scoring of abdominal radiographs in the assessment of childhood constipation should be abandoned because it is dependent on the experience of the observer, is poorly reproducible, and does not accurately discriminate between constipated children and children without constipation. (orig.)

  7. Diagnostic accuracy of the Barr and Blethyn radiological scoring systems for childhood constipation assessed using colonic transit time as the gold standard

    International Nuclear Information System (INIS)

    Jackson, Claire R.; Wylie, Anna B.Z.; Adams, Charlotte; Lee, Richard E.; Jaffray, Bruce

    2009-01-01

    Constipation is a common childhood symptom and abdominal radiography is advocated in diagnosis and management. To assess the reproducibility and diagnostic accuracy of the Barr and Blethyn systems for quantifying constipation on abdominal radiographs in children. Radiographs were scored by three observers of increasing radiological experience (student, junior doctor, consultant). Abdominal radiographs produced during measurement of colonic transit time (CTT) were classified as constipated or normal based on the value of the transit time, and were scored using both systems by observers blinded to the CTT. Abdominal radiographs obtained in children for reasons other than constipation were classed as normal and similarly scored. Reproducibility was measured using the kappa statistic. Diagnostic accuracy was measured using the area under the curve (AUC) for the receiver operator characteristic (ROC) curve. Using either system, scores were higher for constipated children (P<0.01). The consultant produced higher scores than the other observers (P<0.01). Interobserver reproducibility was moderate with the best kappa value only 0.48. The best correlation between score and CTT was 0.51 (junior doctor scores). Diagnostic accuracy of the scores was only moderate, with the largest AUC for a ROC curve of 0.84 for the consultant using the Barr score. Scoring of abdominal radiographs in the assessment of childhood constipation should be abandoned because it is dependent on the experience of the observer, is poorly reproducible, and does not accurately discriminate between constipated children and children without constipation. (orig.)

  8. Accuracy of clinical signs, SEP, and EEG in predicting outcome of hypoxic coma: a meta-analysis.

    Science.gov (United States)

    Lee, Y C; Phan, T G; Jolley, D J; Castley, H C; Ingram, D A; Reutens, D C

    2010-02-16

    Accurate prediction of neurologic outcome after hypoxic coma is important. Previous systematic reviews have not used summary statistics to summarize and formally compare the accuracy of different prognostic tests. We therefore used summary receiver operating characteristic curve (SROC) and cluster regression methods to compare motor and pupillary responses with sensory evoked potential (SEP) and EEG in predicting outcome after hypoxic coma. We searched PubMed, MEDLINE, and Embase (1966-2007) for reports in English, German, and French and identified 25 suitable studies. An SROC was constructed for each marker (SEP, EEG, M1 and M SEP was larger than those for M1, M SEP (AUC 0.891) and that for M1 (AUC 0.786) was small (0.105, 95% confidence interval 0.023-0.187), only reaching significance on day 1 after coma onset. The use of M SEP) is marginally better than M1 at predicting outcome after hypoxic coma. However, the superiority of SEP diminishes after day 1 and when M SEP is a better marker than clinical signs.

  9. Treatment of the effluent generated in conversion process of auc by precipitation

    International Nuclear Information System (INIS)

    Carvalho, E.F.U. de; Santos, L.R. dos; Riella, H.G.

    1988-01-01

    The purpose of this study is to provide a description for the treatment of generating effluent from Ammonium Uranyl Carbonate-AUC IPEN/CNEN-SP. This procedure describes the uranium recovery (200 mlU/1) by means of its precipitation with hidrogen peroxide at 50 0 C, pH 8,5 where results a yellow powder thought to be UO 4 2NH 3 2HF and a NH 4 F solution with an uranium concentration of 6-7mgU/1. The powder resulted was characterized by chemical analysis and X- Ray difraction techniques. (author) [pt

  10. Development of a high-throughput in vitro assay using a novel Caco-2/rat hepatocyte system for the prediction of oral plasma area under the concentration versus time curve (AUC) in rats.

    Science.gov (United States)

    Cheng, K-C; Li, Cheng; Hsieh, Yunsheng; Montgomery, Diana; Liu, Tongtong; White, Ronald E

    2006-01-01

    Previously, we have shown that a novel Caco-2/human hepatocyte system is a useful model for the prediction of oral bioavailability in humans. In this study, we attempted to use a similar system in a high-throughput screening mode for the selection of new compound entities (NCE) in drug discovery. A total of 72 compounds randomly selected from three different chemotypes were dosed orally in rats. In vivo plasma area under the concentration versus time curve (AUC) from 0-6 h of the parent compound was determined. The same compounds were also tested in the Caco-2/rat hepatocyte system. In vitro AUC from 0-3 h in the Caco-2 rat hepatocyte system was determined. The predictive usefulness of the Caco-2/rat hepatocyte system was evaluated by comparing the in vivo plasma AUC and the in vitro AUC. Linear regression analysis showed a reasonable correlation (R2 = 0.5) between the in vivo AUC and the in vitro AUC. Using 0.4 microM h in vivo AUC as a cut-off, compounds were categorized as either low or high AUC. The in vitro AUC successfully matched the corresponding in vivo category for sixty-three out of seventy-two compounds. The results presented in this study suggest that the Caco-2/rat hepatocyte system may be used as a high-throughput screen in drug discovery for pharmacokinetic behaviors of compounds in rats.

  11. Abbreviated AUC monitoring of cyclosporine more adequately identified patients at risk for acute rejection during induction of immunosuppressive therapy after kidney transplantation than recommended C2 concentration values.

    Science.gov (United States)

    Troncoso, P; Ortiz, A M; Jara, A; Vilches, S

    2009-01-01

    Monitoring of cyclosporine (CsA) is critical during the induction of immunosuppressive therapy. Although most centers have incorporated C2 levels, our unit still uses an abbreviated AUC model which includes concentrations at C1, C2, and C6 post-dose (AUC(1-6)). The objective of this study was to compare both strategies of CsA monitoring during the first 30 days after kidney transplantation. The study included 89 recipients induced with CsA microemulsion and steroids. AUC(1-6) profiles were performed around days 3, 10, and 30 after transplantation with a target of 5500 to 6000 ng*h/mL considered therapeutic. For comparison purposes, a value of C2 >/= 1500 ng/mL was also considered therapeutic. Mean C2 and AUC(1-6) values were low dated with biopsy-proven acute rejection episodes (BPAR) during the study period. Twenty patients received living donor kidneys and overall there were 46 females. During this period, 253 AUC(1-6) were performed including 44 (17.4%) below the therapeutic range. When the analysis included only C2, 171 (67.6%) were below the therapeutic target (P AUC(1-6) at day 10 discriminated rejectors versus nonrejectors (5645 +/- 1390 and 8221 +/- 2502, respectively; P = .008). C2 was not significantly different at any time in either group. In this study, abbreviated AUC monitoring more adequately identified patients at risk for acute rejection than C2. Recommended C2 concentration levels need to be redefined in our patients.

  12. MR-sequences for prostate cancer diagnostics: validation based on the PI-RADS scoring system and targeted MR-guided in-bore biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, Lars; Quentin, Michael; Buchbender, Christian; Antoch, Gerald; Blondin, Dirk [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Arsov, Christian; Hiester, Andreas; Rabenalt, Robert; Albers, Peter [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany)

    2014-10-15

    This study evaluated the accuracy of MR sequences [T2-, diffusion-weighted, and dynamic contrast-enhanced (T2WI, DWI, and DCE) imaging] at 3T, based on the European Society of Urogenital Radiology (ESUR) scoring system [Prostate Imaging Reporting and Data System (PI-RADS)] using MR-guided in-bore prostate biopsies as reference standard. In 235 consecutive patients [aged 65.7 ± 7.9 years; median prostate-specific antigen (PSA) 8 ng/ml] with multiparametric prostate MRI (mp-MRI), 566 lesions were scored according to PI-RADS. Histology of all lesions was obtained by targeted MR-guided in-bore biopsy. In 200 lesions, biopsy revealed prostate cancer (PCa). The area under the curve (AUC) for cancer detection was 0.70 (T2WI), 0.80 (DWI), and 0.74 (DCE). A combination of T2WI + DWI, T2WI + DCE, and DWI + DCE achieved an AUC of 0.81, 0.78, and 0.79. A summed PI-RADS score of T2WI + DWI + DCE achieved an AUC of 0.81. For higher grade PCa (primary Gleason pattern ≥ 4), the AUC was 0.85 for T2WI + DWI, 0.84 for T2WI + DCE, 0.86 for DWI + DCE, and 0.87 for T2WI + DWI + DCE. The AUC for T2WI + DWI + DCE for transitional-zone PCa was 0.73, and for the peripheral zone 0.88. Regarding higher-grade PCa, AUC for transitional-zone PCa was 0.88, and for peripheral zone 0.96. The combination of T2WI + DWI + DCE achieved the highest test accuracy, especially in patients with higher-grade PCa. The use of ≤2 MR sequences led to lower AUC in higher-grade and peripheral-zone cancers. (orig.)

  13. MR-sequences for prostate cancer diagnostics: validation based on the PI-RADS scoring system and targeted MR-guided in-bore biopsy

    International Nuclear Information System (INIS)

    Schimmoeller, Lars; Quentin, Michael; Buchbender, Christian; Antoch, Gerald; Blondin, Dirk; Arsov, Christian; Hiester, Andreas; Rabenalt, Robert; Albers, Peter

    2014-01-01

    This study evaluated the accuracy of MR sequences [T2-, diffusion-weighted, and dynamic contrast-enhanced (T2WI, DWI, and DCE) imaging] at 3T, based on the European Society of Urogenital Radiology (ESUR) scoring system [Prostate Imaging Reporting and Data System (PI-RADS)] using MR-guided in-bore prostate biopsies as reference standard. In 235 consecutive patients [aged 65.7 ± 7.9 years; median prostate-specific antigen (PSA) 8 ng/ml] with multiparametric prostate MRI (mp-MRI), 566 lesions were scored according to PI-RADS. Histology of all lesions was obtained by targeted MR-guided in-bore biopsy. In 200 lesions, biopsy revealed prostate cancer (PCa). The area under the curve (AUC) for cancer detection was 0.70 (T2WI), 0.80 (DWI), and 0.74 (DCE). A combination of T2WI + DWI, T2WI + DCE, and DWI + DCE achieved an AUC of 0.81, 0.78, and 0.79. A summed PI-RADS score of T2WI + DWI + DCE achieved an AUC of 0.81. For higher grade PCa (primary Gleason pattern ≥ 4), the AUC was 0.85 for T2WI + DWI, 0.84 for T2WI + DCE, 0.86 for DWI + DCE, and 0.87 for T2WI + DWI + DCE. The AUC for T2WI + DWI + DCE for transitional-zone PCa was 0.73, and for the peripheral zone 0.88. Regarding higher-grade PCa, AUC for transitional-zone PCa was 0.88, and for peripheral zone 0.96. The combination of T2WI + DWI + DCE achieved the highest test accuracy, especially in patients with higher-grade PCa. The use of ≤2 MR sequences led to lower AUC in higher-grade and peripheral-zone cancers. (orig.)

  14. Pre-Operative Prediction of Advanced Prostatic Cancer Using Clinical Decision Support Systems: Accuracy Comparison between Support Vector Machine and Artificial Neural Network

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Youn; Moon, Sung Kyoung; Hwang, Sung Il; Sung, Chang Kyu; Cho, Jeong Yeon; Kim, Seung Hyup; Lee, Hak Jong [Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Dae Chul [National Cancer Center, Ilsan (Korea, Republic of); Lee, Ji Won [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2011-10-15

    The purpose of the current study was to develop support vector machine (SVM) and artificial neural network (ANN) models for the pre-operative prediction of advanced prostate cancer by using the parameters acquired from transrectal ultrasound (TRUS)-guided prostate biopsies, and to compare the accuracies between the two models. Five hundred thirty-two consecutive patients who underwent prostate biopsies and prostatectomies for prostate cancer were divided into the training and test groups (n = 300 versus n 232). From the data in the training group, two clinical decision support systems (CDSSs-[SVM and ANN]) were constructed with input (age, prostate specific antigen level, digital rectal examination, and five biopsy parameters) and output data (the probability for advanced prostate cancer [> pT3a]). From the data of the test group, the accuracy of output data was evaluated. The areas under the receiver operating characteristic (ROC) curve (AUC) were calculated to summarize the overall performances, and a comparison of the ROC curves was performed (p < 0.05). The AUC of SVM and ANN is 0.805 and 0.719, respectively (p = 0.020), in the pre-operative prediction of advanced prostate cancer. Te performance of SVM is superior to ANN in the pre-operative prediction of advanced prostate cancer.

  15. Whole-tumor histogram analysis of the cerebral blood volume map: tumor volume defined by 11C-methionine positron emission tomography image improves the diagnostic accuracy of cerebral glioma grading.

    Science.gov (United States)

    Wu, Rongli; Watanabe, Yoshiyuki; Arisawa, Atsuko; Takahashi, Hiroto; Tanaka, Hisashi; Fujimoto, Yasunori; Watabe, Tadashi; Isohashi, Kayako; Hatazawa, Jun; Tomiyama, Noriyuki

    2017-10-01

    This study aimed to compare the tumor volume definition using conventional magnetic resonance (MR) and 11C-methionine positron emission tomography (MET/PET) images in the differentiation of the pre-operative glioma grade by using whole-tumor histogram analysis of normalized cerebral blood volume (nCBV) maps. Thirty-four patients with histopathologically proven primary brain low-grade gliomas (n = 15) and high-grade gliomas (n = 19) underwent pre-operative or pre-biopsy MET/PET, fluid-attenuated inversion recovery, dynamic susceptibility contrast perfusion-weighted magnetic resonance imaging, and contrast-enhanced T1-weighted at 3.0 T. The histogram distribution derived from the nCBV maps was obtained by co-registering the whole tumor volume delineated on conventional MR or MET/PET images, and eight histogram parameters were assessed. The mean nCBV value had the highest AUC value (0.906) based on MET/PET images. Diagnostic accuracy significantly improved when the tumor volume was measured from MET/PET images compared with conventional MR images for the parameters of mean, 50th, and 75th percentile nCBV value (p = 0.0246, 0.0223, and 0.0150, respectively). Whole-tumor histogram analysis of CBV map provides more valuable histogram parameters and increases diagnostic accuracy in the differentiation of pre-operative cerebral gliomas when the tumor volume is derived from MET/PET images.

  16. Proposing the Use of Partial AUC as an Adjunctive Measure in Establishing Bioequivalence Between Deltoid and Gluteal Administration of Long-Acting Injectable Antipsychotics.

    Science.gov (United States)

    Lee, Lik Hang N; Choi, Charles; Gershkovich, Pavel; Barr, Alasdair M; Honer, William G; Procyshyn, Ric M

    2016-12-01

    The maximum plasma concentration (C max ) and the area under the plasma concentration-time curve (AUC) are commonly used to establish bioequivalence between two formulations of the same oral medication. Similarly, these pharmacokinetic parameters have also been used to establish bioequivalence between two sites of administration for the same injectable formulation. However, these conventional methods of establishing bioequivalence are of limited use when comparing modified-release formulations of a drug, particularly those with rates of absorption that are amenable to change with the site of injection. Inherent differences in the rate of absorption can result in clinically significant differences in early exposure and drug response. Here, we propose the use of the partial AUC (pAUC) as a measure of early exposure to aid in the assessment of bioequivalence between the gluteal and the deltoid site of administration for long-acting injectable antipsychotics.

  17. Classification of suicide attempters in schizophrenia using sociocultural and clinical features: A machine learning approach.

    Science.gov (United States)

    Hettige, Nuwan C; Nguyen, Thai Binh; Yuan, Chen; Rajakulendran, Thanara; Baddour, Jermeen; Bhagwat, Nikhil; Bani-Fatemi, Ali; Voineskos, Aristotle N; Mallar Chakravarty, M; De Luca, Vincenzo

    2017-07-01

    Suicide is a major concern for those afflicted by schizophrenia. Identifying patients at the highest risk for future suicide attempts remains a complex problem for psychiatric interventions. Machine learning models allow for the integration of many risk factors in order to build an algorithm that predicts which patients are likely to attempt suicide. Currently it is unclear how to integrate previously identified risk factors into a clinically relevant predictive tool to estimate the probability of a patient with schizophrenia for attempting suicide. We conducted a cross-sectional assessment on a sample of 345 participants diagnosed with schizophrenia spectrum disorders. Suicide attempters and non-attempters were clearly identified using the Columbia Suicide Severity Rating Scale (C-SSRS) and the Beck Suicide Ideation Scale (BSS). We developed four classification algorithms using a regularized regression, random forest, elastic net and support vector machine models with sociocultural and clinical variables as features to train the models. All classification models performed similarly in identifying suicide attempters and non-attempters. Our regularized logistic regression model demonstrated an accuracy of 67% and an area under the curve (AUC) of 0.71, while the random forest model demonstrated 66% accuracy and an AUC of 0.67. Support vector classifier (SVC) model demonstrated an accuracy of 67% and an AUC of 0.70, and the elastic net model demonstrated and accuracy of 65% and an AUC of 0.71. Machine learning algorithms offer a relatively successful method for incorporating many clinical features to predict individuals at risk for future suicide attempts. Increased performance of these models using clinically relevant variables offers the potential to facilitate early treatment and intervention to prevent future suicide attempts. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Anatomic features of the neck as predictive markers of difficult direct laryngoscopy in men and women: A prospective study.

    Science.gov (United States)

    Liaskou, Chara; Chara, Liaskou; Vouzounerakis, Eleftherios; Eleftherios, Vouzounerakis; Moirasgenti, Maria; Maria, Moirasgenti; Trikoupi, Anastasia; Anastasia, Trikoupi; Staikou, Chryssoula; Chryssoula, Staikou

    2014-03-01

    Difficult airway assessment is based on various anatomic parameters of upper airway, much of it being concentrated on oral cavity and the pharyngeal structures. The diagnostic value of tests based on neck anatomy in predicting difficult laryngoscopy was assessed in this prospective, open cohort study. We studied 341 adult patients scheduled to receive general anaesthesia. Thyromental distance (TMD), sternomental distance (STMD), ratio of height to thyromental distance (RHTMD) and neck circumference (NC) were measured pre-operatively. The laryngoscopic view was classified according to the Cormack-Lehane Grade (1-4). Difficult laryngoscopy was defined as Cormack-Lehane Grade 3 or 4. The optimal cut-off points for each variable were identified by using receiver operating characteristic analysis. Sensitivity, specificity and positive predictive value and negative predictive value (NPV) were calculated for each test. Multivariate analysis with logistic regression, including all variables, was used to create a predictive model. Comparisons between genders were also performed. Laryngoscopy was difficult in 12.6% of the patients. The cut-off values were: TMD ≤7 cm, STMD ≤15 cm, RHTMD >18.4 and NC >37.5 cm. The RHTMD had the highest sensitivity (88.4%) and NPV (95.2%), while TMD had the highest specificity (83.9%). The area under curve (AUC) for the TMD, STMD, RHTMD and NC was 0.63, 0.64, 0.62 and 0.54, respectively. The predictive model exhibited a higher and statistically significant diagnostic accuracy (AUC: 0.68, P < 0.001). Gender-specific cut-off points improved the predictive accuracy of NC in women (AUC: 0.65). The TMD, STMD, RHTMD and NC were found to be poor single predictors of difficult laryngoscopy, while a model including all four variables had a significant predictive accuracy. Among the studied tests, gender-specific cut-off points should be used for NC.

  19. Improved Accuracy of Myocardial Perfusion SPECT for the Detection of Coronary Artery Disease by Utilizing a Support Vector Machines Algorithm

    Science.gov (United States)

    Arsanjani, Reza; Xu, Yuan; Dey, Damini; Fish, Matthews; Dorbala, Sharmila; Hayes, Sean; Berman, Daniel; Germano, Guido; Slomka, Piotr

    2012-01-01

    We aimed to improve the diagnostic accuracy of automatic myocardial perfusion SPECT (MPS) interpretation analysis for prediction of coronary artery disease (CAD) by integrating several quantitative perfusion and functional variables for non-corrected (NC) data by support vector machines (SVM), a computer method for machine learning. Methods 957 rest/stress 99mtechnetium gated MPS NC studies from 623 consecutive patients with correlating invasive coronary angiography and 334 with low likelihood of CAD (LLK < 5% ) were assessed. Patients with stenosis ≥ 50% in left main or ≥ 70% in all other vessels were considered abnormal. Total perfusion deficit (TPD) was computed automatically. In addition, ischemic changes (ISCH) and ejection fraction changes (EFC) between stress and rest were derived by quantitative software. The SVM was trained using a group of 125 pts (25 LLK, 25 0-, 25 1-, 25 2- and 25 3-vessel CAD) using above quantitative variables and second order polynomial fitting. The remaining patients (N = 832) were categorized based on probability estimates, with CAD defined as (probability estimate ≥ 0.50). The diagnostic accuracy of SVM was also compared to visual segmental scoring by two experienced readers. Results Sensitivity of SVM (84%) was significantly better than ISCH (75%, p < 0.05) and EFC (31%, p < 0.05). Specificity of SVM (88%) was significantly better than that of TPD (78%, p < 0.05) and EFC (77%, p < 0.05). Diagnostic accuracy of SVM (86%) was significantly better than TPD (81%), ISCH (81%), or EFC (46%) (p < 0.05 for all). The Receiver-operator-characteristic area-under-the-curve (ROC-AUC) for SVM (0.92) was significantly better than TPD (0.90), ISCH (0.87), and EFC (0.60) (p < 0.001 for all). Diagnostic accuracy of SVM was comparable to the overall accuracy of both visual readers (85% vs. 84%, p < 0.05). ROC-AUC for SVM (0.92) was significantly better than that of both visual readers (0.87 and 0.88, p < 0.03). Conclusion Computational

  20. Endometrial cancer with cervical stromal invasion: diagnostic accuracy of diffusion-weighted and dynamic contrast enhanced MR imaging at 3T

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Gigin; Lu, Hsin-Ying [Chang Gung Memorial Hospital at Linkou and Chang Gung University, Department of Medical Imaging and Intervention, Institute for Radiological Research, Guishan, Taoyuan (China); Chang Gung Memorial Hospital at Linkou, Clinical Phenome Center, Guishan, Taoyuan (China); Huang, Yu-Ting; Lin, Yu-Chun; Ng, Shu-Hang; Ng, Koon-Kwan [Chang Gung Memorial Hospital at Linkou and Chang Gung University, Department of Medical Imaging and Intervention, Institute for Radiological Research, Guishan, Taoyuan (China); Chao, Angel; Lai, Chyong-Huey [Chang Gung Memorial Hospital at Linkou and Chang Gung University, Department of Obstetrics and Gynecology and Gynecologic Cancer Research Center, Guishan, Taoyuan (China); Yang, Lan-Yan [Chang Gung Memorial Hospital at Linkou and Chang Gung University, Clinical Trial Center, Guishan, Taoyuan (China); Wu, Ren-Chin [Chang Gung Memorial Hospital at Linkou and Chang Gung University, Department of Pathology, Guishan, Taoyuan (China)

    2017-05-15

    To compare the diagnostic accuracy of diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) magnetic resonance (MR) imaging for detecting cervical stromal invasion in endometrial cancer. Eighty-three consecutive women with endometrial cancer underwent preoperative evaluation in a 3-T unit, including T2-weighted, DW (b = 0 and 1000 s/mm{sup 2}), and DCE MR imaging. Two radiologists independently assessed presence of cervical stromal invasion, with histopathological reference as gold standard. For assessing cervical stromal invasion, the diagnostic accuracy, sensitivity, and specificity, respectively for Reader 1/Reader 2, were as follows: DW MR imaging - 95.2 %/91.6 %, 91.7 %/100 %, and 95.8 %/90.1 %; DCE MR imaging - 91.6 %/88 %, 58.3 %/50 %, and 97.2 %/94.4 %. The diagnostic performance of DW MR imaging (Reader 1: areas under the receiver operating characteristic curve (AUC) = 0.98; Reader 2: AUC = 0.97) was significantly higher than that of DCE MR imaging (p = 0.009 for Reader 2) or T2-weighted MR imaging (Reader 1: p = 0.006; Reader 2: p = 0.013). Patients with cervical stromal invasion showed a significantly greater canal width (p < 0.0001) and myometrial invasion extent (p = 0.006). DW MR imaging has superior diagnostic performance compared with DCE MR imaging in the detection of cervical stromal invasion. (orig.)

  1. Are Vancomycin Trough Concentrations of 15 to 20 mg/L Associated With Increased Attainment of an AUC/MIC ≥ 400 in Patients With Presumed MRSA Infection?

    Science.gov (United States)

    Hale, Cory M; Seabury, Robert W; Steele, Jeffrey M; Darko, William; Miller, Christopher D

    2017-06-01

    To determine whether there is an association between higher vancomycin trough concentrations and attainment of a calculated area under the concentration-time curve (AUC)/minimum inhibitory concentration (MIC) ≥400. A retrospective analysis was conducted among vancomycin-treated adult patients with a positive methicillin-resistant Staphylococcus aureus (MRSA) culture. Attainment of a calculated AUC/MIC ≥400 was compared between patients with troughs in the reference range of 15 to 20 mg/L and those with troughs in the following ranges: 20 mg/L. Nephrotoxicity was assessed as a secondary outcome based on corrected average vancomycin troughs over 10 days of treatment. Overall, 226 patients were reviewed and 100 included. Relative to troughs ≥10, patients with vancomycin troughs AUC/MIC ≥400 (odds ratio [OR] 0.27, 95% confidence interval [CI]: 0.01-0.75). No difference was found in the attainment of an AUC/MIC ≥400 in patients with troughs of 10 to 14.9 mg/L and >20 mg/L when compared to patients with troughs of 15 to 20 mg/L. The mean corrected average vancomycin trough was higher in patients developing nephrotoxicity compared to those who did not (19.5 vs 14.5 mg/L, P AUC/MIC target relative to troughs of 10 to 14.9 mg/L but may increase nephrotoxicity risk.

  2. Long Term Measurement of the Vapor Pressure of Gold in the Au-C System

    Science.gov (United States)

    Copland, Evan H.

    2009-01-01

    Incorporating the {Au(s,l) + graphite} reference in component activity measurements made with the multiple effusion-cell vapor source mass spectrometry (multicell KEMS) technique provides a fixed temperature defining ITS-90 (T(sub mp)(Au) = 1337.33K) and a systematic method to check accuracy. Over a 2 year period delta H sub(298)Au was determined by the 2nd and 3rd law methods in 25 separate experiments and were in the ranges 362.2 plus or minus 3.3 kJmol(sup -1) and 367.8 plus or minus 1.1 kJmol(sup -1), respectively. This 5 kJmol-1 discrepancy is transferred directly to the measured activities. This is unacceptable and the source of this discrepancy needs to be understood and corrected. Accepting the 2nd law value increases p(Au) by about 50 percent, brings the 2nd and 3rd law values into agreement and removes the T dependence in the 3rd law values. While compelling, there is no way to independently determine instrument sensitivities, S(sub Au), with T in a single experiment with KEMS. This lack of capability is stopping a deeper understanding of this problem. In addition, the Au-C phase diagram suggests a eutectic invariant reaction: L-Au(4.7at%C) = FCC-Au(0.08at%C) + C(graphite) at T(sub e) approximately 1323K. This high C concentration in Au(l) must reduce p(Au) in equilibrium with {Au(s,l) + graphite} and raises some critical questions about the Gibbs free energy functions of Au(s,l) and the Au fixed point (T(sub mp)(Au) = 1337.33K) which is always measured in graphite.

  3. Catching the Highest Energy Neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Stanev, Todor [Bartol Research Institute and Department of Physics and Astronomy, University of Delaware, Newark, DE 19716 (United States)

    2011-08-15

    We briefly discuss the possible sources of ultrahigh energy neutrinos and the methods for their detection. Then we present the results obtained by different experiments for detection of the highest energy neutrinos.

  4. Diagnostic accuracy of a noninvasive hepatic ultrasound score for non-alcoholic fatty liver disease (NAFLD in the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil

    Directory of Open Access Journals (Sweden)

    Alessandra Carvalho Goulart

    Full Text Available CONTEXT AND OBJECTIVE: Noninvasive strategies for evaluating non-alcoholic fatty liver disease (NAFLD have been investigated over the last few decades. Our aim was to evaluate the diagnostic accuracy of a new hepatic ultrasound score for NAFLD in the ELSA-Brasil study. DESIGN AND SETTINGS: Diagnostic accuracy study conducted in the ELSA center, in the hospital of a public university. METHODS: Among the 15,105 participants of the ELSA study who were evaluated for NAFLD, 195 individuals were included in this sub-study. Hepatic ultrasound was performed (deep beam attenuation, hepatorenal index and anteroposterior diameter of the right hepatic lobe and compared with the hepatic steatosis findings from 64-channel high-resolution computed tomography (CT. We also evaluated two clinical indices relating to NAFLD: the fatty liver index (FLI and the hepatic steatosis index (HSI. RESULTS: Among the 195 participants, the NAFLD frequency was 34.4%. High body mass index, high waist circumference, diabetes and hypertriglyceridemia were associated with high hepatic attenuation and large anteroposterior diameter of the right hepatic lobe, but not with the hepatorenal index. The hepatic ultrasound score, based on hepatic attenuation and the anteroposterior diameter of the right hepatic lobe, presented the best performance for NAFLD screening at the cutoff point ≥ 1 point; sensitivity: 85.1%; specificity: 73.4%; accuracy: 79.3%; and area under the curve (AUC 0.85; 95% confidence interval, CI: 0.78-0.91]. FLI and HSI presented lower performance (AUC 0.76; 95% CI: 0.69-0.83 than CT. CONCLUSION: The hepatic ultrasound score based on hepatic attenuation and the anteroposterior diameter of the right hepatic lobe has good reproducibility and accuracy for NAFLD screening.

  5. Diagnostic accuracy of a noninvasive hepatic ultrasound score for non-alcoholic fatty liver disease (NAFLD) in the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil).

    Science.gov (United States)

    Goulart, Alessandra Carvalho; Oliveira, Ilka Regina Souza de; Alencar, Airlane Pereira; Santos, Maira Solange Camara dos; Santos, Itamar Souza; Martines, Brenda Margatho Ramos; Meireles, Danilo Peron; Martines, João Augusto dos Santos; Misciagna, Giovanni; Benseñor, Isabela Martins; Lotufo, Paulo Andrade

    2015-01-01

    Noninvasive strategies for evaluating non-alcoholic fatty liver disease (NAFLD) have been investigated over the last few decades. Our aim was to evaluate the diagnostic accuracy of a new hepatic ultrasound score for NAFLD in the ELSA-Brasil study. Diagnostic accuracy study conducted in the ELSA center, in the hospital of a public university. Among the 15,105 participants of the ELSA study who were evaluated for NAFLD, 195 individuals were included in this sub-study. Hepatic ultrasound was performed (deep beam attenuation, hepatorenal index and anteroposterior diameter of the right hepatic lobe) and compared with the hepatic steatosis findings from 64-channel high-resolution computed tomography (CT). We also evaluated two clinical indices relating to NAFLD: the fatty liver index (FLI) and the hepatic steatosis index (HSI). Among the 195 participants, the NAFLD frequency was 34.4%. High body mass index, high waist circumference, diabetes and hypertriglyceridemia were associated with high hepatic attenuation and large anteroposterior diameter of the right hepatic lobe, but not with the hepatorenal index. The hepatic ultrasound score, based on hepatic attenuation and the anteroposterior diameter of the right hepatic lobe, presented the best performance for NAFLD screening at the cutoff point ≥ 1 point; sensitivity: 85.1%; specificity: 73.4%; accuracy: 79.3%; and area under the curve (AUC 0.85; 95% confidence interval, CI: 0.78-0.91)]. FLI and HSI presented lower performance (AUC 0.76; 95% CI: 0.69-0.83) than CT. The hepatic ultrasound score based on hepatic attenuation and the anteroposterior diameter of the right hepatic lobe has good reproducibility and accuracy for NAFLD screening.

  6. Hidden Hydride Transfer as a Decisive Mechanistic Step in the Reactions of the Unligated Gold Carbide [AuC]+ with Methane under Ambient Conditions.

    Science.gov (United States)

    Li, Jilai; Zhou, Shaodong; Schlangen, Maria; Weiske, Thomas; Schwarz, Helmut

    2016-10-10

    The reactivity of the cationic gold carbide [AuC] + (bearing an electrophilic carbon atom) towards methane has been studied using Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS). The product pairs generated, that is, Au + /C 2 H 4 , [Au(C 2 H 2 )] + /H 2 , and [C 2 H 3 ] + /AuH, point to the breaking and making of C-H, C-C, and H-H bonds under single-collision conditions. The mechanisms of these rather efficient reactions have been elucidated by high-level quantum-chemical calculations. As a major result, based on molecular orbital and NBO-based charge analysis, an unprecedented hydride transfer from methane to the carbon atom of [AuC] + has been identified as a key step. Also, the origin of this novel mechanistic scenario has been addressed. The mechanistic insights derived from this study may provide guidance for the rational design of carbon-based catalysts. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Diagnostic accuracy of apparent diffusion coefficient and 123I-metaiodobenzylguanidine for differentiation of multiple system atrophy and Parkinson's disease.

    Directory of Open Access Journals (Sweden)

    Atsushi Umemura

    Full Text Available BACKGROUND: It is often hard to differentiate Parkinson's disease (PD and parkinsonian variant of multiple system atrophy (MSA-P, especially in the early stages. Cardiac sympathetic denervation and putaminal rarefaction are specific findings for PD and MSA-P, respectively. PURPOSE: We investigated diagnostic accuracy of putaminal apparent diffusion coefficient (ADC test for MSA-P and (123I-metaiodobenzylguanidine (MIBG scintigram for PD, especially in early-stage patients. METHODS: The referral standard diagnosis of PD and MSA-P were the diagnostic criteria of the United Kingdom Parkinson's Disease Society Brain Bank Criteria and the second consensus criteria, respectively. Based on the referral standard criteria, diagnostic accuracy [area under the receiver-operator characteristic curve (AUC, sensitivity and specificity] of the ADC and MIBG tests was estimated retrospectively. Diagnostic accuracy of these tests performed within 3 years of symptom onset was also investigated. RESULTS: ADC and MIBG tests were performed on 138 patients (20 MSA and 118 PD. AUC was 0.95 and 0.83 for the ADC and MIBG tests, respectively. Sensitivity and specificity were 85.0% and 89.0% for MSA-P diagnosis by ADC test and 67.0% and 80.0% for PD diagnosis by MIBG test. When these tests were restricted to patients with disease duration ≤ 3 years, the sensitivity and specificity were 75.0% and 91.4% for the ADC test (MSA-P diagnosis and 47.7% and 92.3% for the MIBG test (PD diagnosis. CONCLUSIONS: Both tests were useful in differentiating between PD and MSA-P, even in the early stages. In early-stage patients, elevated putaminal ADC was a diagnostic marker for MSA-P. Despite high specificity of the MIBG test, careful neurological history and examinations were required for PD diagnosis because of possible false-negative results.

  8. Diagnostic accuracy of apparent diffusion coefficient and 123I-metaiodobenzylguanidine for differentiation of multiple system atrophy and Parkinson's disease.

    Science.gov (United States)

    Umemura, Atsushi; Oeda, Tomoko; Hayashi, Ryutaro; Tomita, Satoshi; Kohsaka, Masayuki; Yamamoto, Kenji; Sawada, Hideyuki

    2013-01-01

    It is often hard to differentiate Parkinson's disease (PD) and parkinsonian variant of multiple system atrophy (MSA-P), especially in the early stages. Cardiac sympathetic denervation and putaminal rarefaction are specific findings for PD and MSA-P, respectively. We investigated diagnostic accuracy of putaminal apparent diffusion coefficient (ADC) test for MSA-P and (123)I-metaiodobenzylguanidine (MIBG) scintigram for PD, especially in early-stage patients. The referral standard diagnosis of PD and MSA-P were the diagnostic criteria of the United Kingdom Parkinson's Disease Society Brain Bank Criteria and the second consensus criteria, respectively. Based on the referral standard criteria, diagnostic accuracy [area under the receiver-operator characteristic curve (AUC), sensitivity and specificity] of the ADC and MIBG tests was estimated retrospectively. Diagnostic accuracy of these tests performed within 3 years of symptom onset was also investigated. ADC and MIBG tests were performed on 138 patients (20 MSA and 118 PD). AUC was 0.95 and 0.83 for the ADC and MIBG tests, respectively. Sensitivity and specificity were 85.0% and 89.0% for MSA-P diagnosis by ADC test and 67.0% and 80.0% for PD diagnosis by MIBG test. When these tests were restricted to patients with disease duration ≤ 3 years, the sensitivity and specificity were 75.0% and 91.4% for the ADC test (MSA-P diagnosis) and 47.7% and 92.3% for the MIBG test (PD diagnosis). Both tests were useful in differentiating between PD and MSA-P, even in the early stages. In early-stage patients, elevated putaminal ADC was a diagnostic marker for MSA-P. Despite high specificity of the MIBG test, careful neurological history and examinations were required for PD diagnosis because of possible false-negative results.

  9. Accuracy assessment of seven global land cover datasets over China

    Science.gov (United States)

    Yang, Yongke; Xiao, Pengfeng; Feng, Xuezhi; Li, Haixing

    2017-03-01

    Land cover (LC) is the vital foundation to Earth science. Up to now, several global LC datasets have arisen with efforts of many scientific communities. To provide guidelines for data usage over China, nine LC maps from seven global LC datasets (IGBP DISCover, UMD, GLC, MCD12Q1, GLCNMO, CCI-LC, and GlobeLand30) were evaluated in this study. First, we compared their similarities and discrepancies in both area and spatial patterns, and analysed their inherent relations to data sources and classification schemes and methods. Next, five sets of validation sample units (VSUs) were collected to calculate their accuracy quantitatively. Further, we built a spatial analysis model and depicted their spatial variation in accuracy based on the five sets of VSUs. The results show that, there are evident discrepancies among these LC maps in both area and spatial patterns. For LC maps produced by different institutes, GLC 2000 and CCI-LC 2000 have the highest overall spatial agreement (53.8%). For LC maps produced by same institutes, overall spatial agreement of CCI-LC 2000 and 2010, and MCD12Q1 2001 and 2010 reach up to 99.8% and 73.2%, respectively; while more efforts are still needed if we hope to use these LC maps as time series data for model inputting, since both CCI-LC and MCD12Q1 fail to represent the rapid changing trend of several key LC classes in the early 21st century, in particular urban and built-up, snow and ice, water bodies, and permanent wetlands. With the highest spatial resolution, the overall accuracy of GlobeLand30 2010 is 82.39%. For the other six LC datasets with coarse resolution, CCI-LC 2010/2000 has the highest overall accuracy, and following are MCD12Q1 2010/2001, GLC 2000, GLCNMO 2008, IGBP DISCover, and UMD in turn. Beside that all maps exhibit high accuracy in homogeneous regions; local accuracies in other regions are quite different, particularly in Farming-Pastoral Zone of North China, mountains in Northeast China, and Southeast Hills. Special

  10. Thermal Analysis of the Decomposition of Ammonium Uranyl Carbonate (AUC) in Different Atmospheres

    DEFF Research Database (Denmark)

    Hälldahl, L.; Sørensen, Ole Toft

    1979-01-01

    The intermediate products formed during thermal decomposition of ammonium uranyl carbonate (AUC) in different atmospheres, (air, helium and hydrogen) have been determined by thermal analysis, (TG, and DTA) and X-ray analysis. The endproducts observed are U3O8 and UO2 in air/He and hydrogen, respe......, respectively. The following intermediate products were observed in all atmospheres: http://www.sciencedirect.com.globalproxy.cvt.dk/cache/MiamiImageURL/B6THV-44K80TV-FB-1/0?wchp=dGLzVlz-zSkWW X-ray diffraction analysis showed that these phases were amorphous....

  11. Accuracy of chest radiographs in the emergency diagnosis of heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Studler, Ueli; Kretzschmar, Martin; Steinbrich, Wolfgang [University Hospital Basel, Department of Radiology, Basel (Switzerland); Christ, Michael; Breidthardt, Tobias; Noveanu, Markus; Perruchoud, Andre P.; Mueller, Christian [University Hospital Basel, Department of Internal Medicine, Basel (Switzerland); Schoetzau, Andreas [Institute of Biostatistics, Basel (Switzerland)

    2008-08-15

    The purpose of this study was to determine the diagnostic accuracy of chest radiographic findings of heart failure (HF) in current patients presenting with dyspnea in the emergency department. In a secondary analysis of the BASEL study, initial chest radiographs of 277 patients with acute dyspnea were evaluated by two radiologists blinded to the adjudicated diagnosis (56% had the final diagnosis of HF). Predefined radiographic criteria of HF were used. Statistical analysis included receiver-operating characteristic (ROC) analysis and calculation of a logistic regression model including B-type natriuretic peptide (BNP) levels. The reader's overall impression showed the highest area under the ROC curve for the diagnosis of HF in both supine and erect patient positions (0.855 and 0.857). Among individual radiographic findings, peribronchial cuffing in the supine position (0.829) showed the highest accuracies. The lowest accuracy was found for the vascular pedicle width in the supine position (0.461). Logistic regression analysis showed no significant differences between the reader's overall impression, the radiographic model, and BNP testing. In our study, the combination of radiographic features provided valuable information and was of comparable accuracy as BNP-testing for the diagnosis of HF. (orig.)

  12. Differentiating pheochromocytoma from lipid-poor adrenocortical adenoma by CT texture analysis: feasibility study.

    Science.gov (United States)

    Zhang, Gu-Mu-Yang; Shi, Bing; Sun, Hao; Jin, Zheng-Yu; Xue, Hua-Dan

    2017-09-01

    To investigate the feasibility of using CT texture analysis (CTTA) to differentiate pheochromocytoma from lipid-poor adrenocortical adenoma (lp-ACA). Ninety-eight pheochromocytomas and 66 lp-ACAs were included in this retrospective study. CTTA was performed on unenhanced and enhanced images. Receiver operating characteristic (ROC) analysis was performed, and the area under the ROC curve (AUC) was calculated for texture parameters that were significantly different for the objective. Diagnostic accuracies were evaluated using the cutoff values of texture parameters with the highest AUCs. Compared to lp-ACAs, pheochromocytomas had significantly higher mean gray-level intensity (Mean), entropy, and mean of positive pixels (MPP), but lower skewness and kurtosis on unenhanced images (P feasible to use CTTA to differentiate pheochromocytoma from lp-ACA.

  13. Characteristic of entire corneal topography and tomography for the detection of sub-clinical keratoconus with Zernike polynomials using Pentacam.

    Science.gov (United States)

    Xu, Zhe; Li, Weibo; Jiang, Jun; Zhuang, Xiran; Chen, Wei; Peng, Mei; Wang, Jianhua; Lu, Fan; Shen, Meixiao; Wang, Yuanyuan

    2017-11-28

    The study aimed to characterize the entire corneal topography and tomography for the detection of sub-clinical keratoconus (KC) with a Zernike application method. Normal subjects (n = 147; 147 eyes), sub-clinical KC patients (n = 77; 77 eyes), and KC patients (n = 139; 139 eyes) were imaged with the Pentacam HR system. The entire corneal data of pachymetry and elevation of both the anterior and posterior surfaces were exported from the Pentacam HR software. Zernike polynomials fitting was used to quantify the 3D distribution of the corneal thickness and surface elevation. The root mean square (RMS) values for each order and the total high-order irregularity were calculated. Multimeric discriminant functions combined with individual indices were built using linear step discriminant analysis. Receiver operating characteristic curves determined the diagnostic accuracy (area under the curve, AUC). The 3rd-order RMS of the posterior surface (AUC: 0.928) obtained the highest discriminating capability in sub-clinical KC eyes. The multimeric function, which consisted of the Zernike fitting indices of corneal posterior elevation, showed the highest discriminant ability (AUC: 0.951). Indices generated from the elevation of posterior surface and thickness measurements over the entire cornea using the Zernike method based on the Pentacam HR system were able to identify very early KC.

  14. Alternative methods for CYP2D6 phenotyping: comparison of dextromethorphan metabolic ratios from AUC, single point plasma, and urine.

    Science.gov (United States)

    Chen, Rui; Wang, Haotian; Shi, Jun; Hu, Pei

    2016-05-01

    CYP2D6 is a high polymorphic enzyme. Determining its phenotype before CYP2D6 substrate treatment can avoid dose-dependent adverse events or therapeutic failures. Alternative phenotyping methods of CYP2D6 were compared to aluate the appropriate and precise time points for phenotyping after single-dose and ultiple-dose of 30-mg controlled-release (CR) dextromethorphan (DM) and to explore the antimodes for potential sampling methods. This was an open-label, single and multiple-dose study. 21 subjects were assigned to receive a single dose of CR DM 30 mg orally, followed by a 3-day washout period prior to oral administration of CR DM 30 mg every 12 hours for 6 days. Metabolic ratios (MRs) from AUC∞ after single dosing and from AUC0-12h at steady state were taken as the gold standard. The correlations of metabolic ratios of DM to dextrorphan (MRDM/DX) values based on different phenotyping methods were assessed. Linear regression formulas were derived to calculate the antimodes for potential sample methods. In the single-dose part of the study statistically significant correlations were found between MRDM/DX from AUC∞ and from serial plasma points from 1 to 30 hours or from urine (all p-values < 0.001). In the multiple-dose part, statistically significant correlations were found between MRDM/DX from AUC0-12h on day 6 and MRDM/DX from serial plasma points from 0 to 36 hours after the last dosing (all p-values < 0.001). Based on reported urinary antimode and linear regression analysis, the antimodes of AUC and plasma points were derived to profile the trend of antimodes as the drug concentrations changed. MRDM/DX from plasma points had good correlations with MRDM/DX from AUC. Plasma points from 1 to 30 hours after single dose of 30-mg CR DM and any plasma point at steady state after multiple doses of CR DM could potentially be used for phenotyping of CYP2D6.

  15. Joint confidence region estimation for area under ROC curve and Youden index.

    Science.gov (United States)

    Yin, Jingjing; Tian, Lili

    2014-03-15

    In the field of diagnostic studies, the area under the ROC curve (AUC) serves as an overall measure of a biomarker/diagnostic test's accuracy. Youden index, defined as the overall correct classification rate minus one at the optimal cut-off point, is another popular index. For continuous biomarkers of binary disease status, although researchers mainly evaluate the diagnostic accuracy using AUC, for the purpose of making diagnosis, Youden index provides an important and direct measure of the diagnostic accuracy at the optimal threshold and hence should be taken into consideration in addition to AUC. Furthermore, AUC and Youden index are generally correlated. In this paper, we initiate the idea of evaluating diagnostic accuracy based on AUC and Youden index simultaneously. As the first step toward this direction, this paper only focuses on the confidence region estimation of AUC and Youden index for a single marker. We present both parametric and non-parametric approaches for estimating joint confidence region of AUC and Youden index. We carry out extensive simulation study to evaluate the performance of the proposed methods. In the end, we apply the proposed methods to a real data set. Copyright © 2013 John Wiley & Sons, Ltd.

  16. Diagnostic accuracy of atypical p-ANCA in autoimmune hepatitis using ROC- and multivariate regression analysis.

    Science.gov (United States)

    Terjung, B; Bogsch, F; Klein, R; Söhne, J; Reichel, C; Wasmuth, J-C; Beuers, U; Sauerbruch, T; Spengler, U

    2004-09-29

    Antineutrophil cytoplasmic antibodies (atypical p-ANCA) are detected at high prevalence in sera from patients with autoimmune hepatitis (AIH), but their diagnostic relevance for AIH has not been systematically evaluated so far. Here, we studied sera from 357 patients with autoimmune (autoimmune hepatitis n=175, primary sclerosing cholangitis (PSC) n=35, primary biliary cirrhosis n=45), non-autoimmune chronic liver disease (alcoholic liver cirrhosis n=62; chronic hepatitis C virus infection (HCV) n=21) or healthy controls (n=19) for the presence of various non-organ specific autoantibodies. Atypical p-ANCA, antinuclear antibodies (ANA), antibodies against smooth muscles (SMA), antibodies against liver/kidney microsomes (anti-Lkm1) and antimitochondrial antibodies (AMA) were detected by indirect immunofluorescence microscopy, antibodies against the M2 antigen (anti-M2), antibodies against soluble liver antigen (anti-SLA/LP) and anti-Lkm1 by using enzyme linked immunosorbent assays. To define the diagnostic precision of the autoantibodies, results of autoantibody testing were analyzed by receiver operating characteristics (ROC) and forward conditional logistic regression analysis. Atypical p-ANCA were detected at high prevalence in sera from patients with AIH (81%) and PSC (94%). ROC- and logistic regression analysis revealed atypical p-ANCA and SMA, but not ANA as significant diagnostic seromarkers for AIH (atypical p-ANCA: AUC 0.754+/-0.026, odds ratio [OR] 3.4; SMA: 0.652+/-0.028, OR 4.1). Atypical p-ANCA also emerged as the only diagnostically relevant seromarker for PSC (AUC 0.690+/-0.04, OR 3.4). None of the tested antibodies yielded a significant diagnostic accuracy for patients with alcoholic liver cirrhosis, HCV or healthy controls. Atypical p-ANCA along with SMA represent a seromarker with high diagnostic accuracy for AIH and should be explicitly considered in a revised version of the diagnostic score for AIH.

  17. Dual Incorporation of the in vitro Data (IC50) and in vivo (Cmax) Data for the Prediction of Area Under the Curve (AUC) for Statins using Regression Models Developed for Either Pravastatin or Simvastatin.

    Science.gov (United States)

    Srinivas, N R

    2016-08-01

    Linear regression models utilizing a single time point (Cmax) has been reported for pravastatin and simvastatin. A new model was developed for the prediction of AUC of statins that utilized the slopes of the above 2 models, with pharmacokinetic (Cmax) and a pharmacodynamic (IC50 value) components for the statins. The prediction of AUCs for various statins (pravastatin, atorvastatin, simvastatin and rosuvastatin) was carried out using the newly developed dual pharmacokinetic and pharmacodynamic model. Generally, the AUC predictions were contained within 0.5 to 2-fold difference of the observed AUC suggesting utility of the new models. The root mean square error predictions wereAUC for statins. Such a new concept as described in the work may have utility in both drug discovery and development stages. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Estimation of chloroform inhalation dose by other routes based on the relationship of area under the blood concentration-time curve (AUC)-inhalation dose to chloroform distribution in the blood of rats.

    Science.gov (United States)

    Take, Makoto; Takeuchi, Tetsuya; Haresaku, Mitsuru; Matsumoto, Michiharu; Nagano, Kasuke; Yamamoto, Seigo; Takamura-Enya, Takeji; Fukushima, Shoji

    2014-01-01

    The present study investigated the time-course changes of concentration of chloroform (CHCl3) in the blood during and after exposure of male rats to CHCl3 by inhalation. Increasing the dose of CHCl3 in the inhalation exposed groups caused a commensurate increase in the concentration of CHCl3 in the blood and the area under the blood concentration-time curve (AUC). There was good correlation (r = 0.988) between the inhalation dose and the AUC/kg body weight. Based on the AUC/kg body weight-inhalation dose curve and the AUC/kg body weight after oral administration, inhalation equivalent doses of orally administered CHCl3 were calculated. Calculation of inhalation equivalent doses allows the body burden due to CHCl3 by inhalation exposure and oral exposure to be directly compared. This type of comparison facilitates risk assessment in humans exposed to CHCl3 by different routes. Our results indicate that when calculating inhalation equivalent doses of CHCl3, it is critical to include the AUC from the exposure period in addition to the AUC after the end of the exposure period. Thus, studies which measure the concentration of volatile organic compounds in the blood during the inhalation exposure period are crucial. The data reported here makes an important contribution to the physiologically based pharmacokinetic (PBPK) database of CHCl3 in rodents.

  19. Validation of limited sampling models (LSM) for estimating AUC in therapeutic drug monitoring - is a separate validation group required?

    NARCIS (Netherlands)

    Proost, J. H.

    Objective: Limited sampling models (LSM) for estimating AUC in therapeutic drug monitoring are usually validated in a separate group of patients, according to published guidelines. The aim of this study is to evaluate the validation of LSM by comparing independent validation with cross-validation

  20. Improving Accuracy for Image Fusion in Abdominal Ultrasonography

    Directory of Open Access Journals (Sweden)

    Caroline Ewertsen

    2012-08-01

    Full Text Available Image fusion involving real-time ultrasound (US is a technique where previously recorded computed tomography (CT or magnetic resonance images (MRI are reformatted in a projection to fit the real-time US images after an initial co-registration. The co-registration aligns the images by means of common planes or points. We evaluated the accuracy of the alignment when varying parameters as patient position, respiratory phase and distance from the co-registration points/planes. We performed a total of 80 co-registrations and obtained the highest accuracy when the respiratory phase for the co-registration procedure was the same as when the CT or MRI was obtained. Furthermore, choosing co-registration points/planes close to the area of interest also improved the accuracy. With all settings optimized a mean error of 3.2 mm was obtained. We conclude that image fusion involving real-time US is an accurate method for abdominal examinations and that the accuracy is influenced by various adjustable factors that should be kept in mind.

  1. Diagnostic Accuracy of Fall Risk Assessment Tools in People With Diabetic Peripheral Neuropathy

    Science.gov (United States)

    Pohl, Patricia S.; Mahnken, Jonathan D.; Kluding, Patricia M.

    2012-01-01

    Background Diabetic peripheral neuropathy affects nearly half of individuals with diabetes and leads to increased fall risk. Evidence addressing fall risk assessment for these individuals is lacking. Objective The purpose of this study was to identify which of 4 functional mobility fall risk assessment tools best discriminates, in people with diabetic peripheral neuropathy, between recurrent “fallers” and those who are not recurrent fallers. Design A cross-sectional study was conducted. Setting The study was conducted in a medical research university setting. Participants The participants were a convenience sample of 36 individuals between 40 and 65 years of age with diabetic peripheral neuropathy. Measurements Fall history was assessed retrospectively and was the criterion standard. Fall risk was assessed using the Functional Reach Test, the Timed “Up & Go” Test, the Berg Balance Scale, and the Dynamic Gait Index. Sensitivity, specificity, positive and negative likelihood ratios, and overall diagnostic accuracy were calculated for each fall risk assessment tool. Receiver operating characteristic curves were used to estimate modified cutoff scores for each fall risk assessment tool; indexes then were recalculated. Results Ten of the 36 participants were classified as recurrent fallers. When traditional cutoff scores were used, the Dynamic Gait Index and Functional Reach Test demonstrated the highest sensitivity at only 30%; the Dynamic Gait Index also demonstrated the highest overall diagnostic accuracy. When modified cutoff scores were used, all tools demonstrated improved sensitivity (80% or 90%). Overall diagnostic accuracy improved for all tests except the Functional Reach Test; the Timed “Up & Go” Test demonstrated the highest diagnostic accuracy at 88.9%. Limitations The small sample size and retrospective fall history assessment were limitations of the study. Conclusions Modified cutoff scores improved diagnostic accuracy for 3 of 4 fall risk

  2. Can Preoperative Magnetic Resonance Imaging Predict the Reparability of Massive Rotator Cuff Tears?

    Science.gov (United States)

    Kim, Jung Youn; Park, Ji Seon; Rhee, Yong Girl

    2017-06-01

    Numerous studies have shown preoperative fatty infiltration of rotator cuff muscles to be strongly negatively correlated with the successful repair of massive rotator cuff tears (RCTs). To assess the association between factors identified on preoperative magnetic resonance imaging (MRI), especially infraspinatus fatty infiltration, and the reparability of massive RCTs. Case-control study; Level of evidence, 3. We analyzed a total of 105 patients with massive RCTs for whom MRI was performed ≤6 months before arthroscopic procedures. The mean age of the patients was 62.7 years (range, 46-83 years), and 46 were men. Among them, complete repair was possible in 50 patients (48%) and not possible in 55 patients (52%). The tangent sign, fatty infiltration of the rotator cuff, and Patte classification were evaluated as predictors of reparability. Using the receiver operating characteristic curve and the area under the curve (AUC), the prediction accuracy of each variable and combinations of variables were measured. Reparability was associated with fatty infiltration of the supraspinatus ( P = .0045) and infraspinatus ( P 3 and grade >2, respectively. The examination of single variables revealed that infraspinatus fatty infiltration showed the highest AUC value (0.812; sensitivity: 0.86; specificity: 0.76), while the tangent sign showed the lowest AUC value (0.626; sensitivity: 0.38; specificity: 0.87). Among 2-variable combinations, the combination of infraspinatus fatty infiltration and the Patte classification showed the highest AUC value (0.874; sensitivity: 0.54; specificity: 0.96). The combination of 4 variables, that is, infraspinatus and supraspinatus fatty infiltration, the tangent sign, and the Patte classification, had an AUC of 0.866 (sensitivity: 0.28; specificity: 0.98), which was lower than the highest AUC value (0.874; sensitivity: 0.54; specificity: 0.96) among the 2-variable combinations. The tangent sign or Patte classification alone was not a predictive

  3. Diagnostic Accuracy of Spectralis SD OCT Automated Macular Layers Segmentation to Discriminate Normal from Early Glaucomatous Eyes.

    Science.gov (United States)

    Pazos, Marta; Dyrda, Agnieszka Anna; Biarnés, Marc; Gómez, Alicia; Martín, Carlos; Mora, Clara; Fatti, Gianluca; Antón, Alfonso

    2017-08-01

    To evaluate the accuracy of the macular retinal layer segmentation software of the Spectralis spectral-domain (SD) optical coherence tomography (OCT) device (Heidelberg Engineering, Inc., Heidelberg, Germany) to discriminate between healthy and early glaucoma (EG) eyes. Prospective, cross-sectional study. Forty EG eyes and 40 healthy controls were included. All participants were examined using the standard posterior pole and the peripapillary retinal nerve fiber layer (pRNFL) protocols of the Spectralis OCT device. Using an Early Treatment Diagnostic Retinopathy Study circle at the macular level, the automated retinal segmentation software was applied to determine thicknesses of the following parameters: total retinal thickness, inner retinal layer (IRL), macular retinal nerve fiber layer (mRNFL), macular ganglion cell layer (mGCL), macular inner plexiform layer (mIPL), macular inner nuclear layer (mINL), macular outer plexiform layer (mOPL), macular outer nuclear layer (mONL), photoreceptors (PR), and retinal pigmentary epithelium (RPE). The ganglion cell complex (GCC) was determined by adding the mRNFL, mGCL, and mIPL parameters and the ganglion cell layer-inner plexiform layer (mGCL-IPL) was determined by combining the mGCL and mIPL parameters. Thickness of each layer was compared between the groups, and the layer and sector with the best area under the receiver operating characteristic curve (AUC) were identified. Comparison of pRNFL, IRL, mRNFL, mGCL, mIPL, mGCC, mGCL-IPL, mINL, mOPL, mONL, PR, and RPE parameters and total retinal thicknesses between groups for the different areas and their corresponding AUCs. Peripapillary RNFL was significantly thinner in the EG group globally and in all 6 sectors assessed (P < 0.0005). For the macular variables, retinal thickness was significantly reduced in the EG group for total retinal thickness, mIRL, mRNFL, mGCL, and mIPL. The 2 best isolated parameters to discriminate between the 2 groups were pRNFL (AUC, 0.956) and

  4. More Accurate Oral Cancer Screening with Fewer Salivary Biomarkers

    Directory of Open Access Journals (Sweden)

    James Michael Menke

    2017-10-01

    Full Text Available Signal detection and Bayesian inferential tools were applied to salivary biomarkers to improve screening accuracy and efficiency in detecting oral squamous cell carcinoma (OSCC. Potential cancer biomarkers are identified by significant differences in assay concentrations, receiver operating characteristic areas under the curve (AUCs, sensitivity, and specificity. However, the end goal is to report to individual patients their risk of having disease given positive or negative test results. Likelihood ratios (LRs and Bayes factors (BFs estimate evidential support and compile biomarker information to optimize screening accuracy. In total, 26 of 77 biomarkers were mentioned as having been tested at least twice in 137 studies and published in 16 summary papers through 2014. Studies represented 10 212 OSCC and 25 645 healthy patients. The measure of biomarker and panel information value was number of biomarkers needed to approximate 100% positive predictive value (PPV. As few as 5 biomarkers could achieve nearly 100% PPV for a disease prevalence of 0.2% when biomarkers were ordered from highest to lowest LR. When sequentially interpreting biomarker tests, high specificity was more important than test sensitivity in achieving rapid convergence toward a high PPV. Biomarkers ranked from highest to lowest LR were more informative and easier to interpret than AUC or Youden index. The proposed method should be applied to more recently published biomarker data to test its screening value.

  5. Statement to commencement ceremony at American University in Cairo (AUC). 9 February 2006, Cairo, Egypt

    Energy Technology Data Exchange (ETDEWEB)

    ElBaradei, M

    2006-02-09

    In its statement to Commencement Ceremony At American University in Cairo (AUC) the Director General of the IAEA reminisced about his life - the twists and turns it had taken, and the lessons he had learned along the way. His messages to the students was to keep thinking and learning, be ready for opportunity when it comes, treat others with the understanding that we are all part of one human family, live your own life, and take joy in it, be proud of your heritage and engage fully in the future of Egypt.

  6. Statement to commencement ceremony at American University in Cairo (AUC). 9 February 2006, Cairo, Egypt

    International Nuclear Information System (INIS)

    ElBaradei, M.

    2006-01-01

    In its statement to Commencement Ceremony At American University in Cairo (AUC) the Director General of the IAEA reminisced about his life - the twists and turns it had taken, and the lessons he had learned along the way. His messages to the students was to keep thinking and learning, be ready for opportunity when it comes, treat others with the understanding that we are all part of one human family, live your own life, and take joy in it, be proud of your heritage and engage fully in the future of Egypt

  7. External validation of blood eosinophils, FE(NO) and serum periostin as surrogates for sputum eosinophils in asthma.

    Science.gov (United States)

    Wagener, A H; de Nijs, S B; Lutter, R; Sousa, A R; Weersink, E J M; Bel, E H; Sterk, P J

    2015-02-01

    Monitoring sputum eosinophils in asthma predicts exacerbations and improves management of asthma. Thus far, blood eosinophils and FE(NO) show contradictory results in predicting eosinophilic airway inflammation. More recently, serum periostin was proposed as a novel biomarker for eosinophilic inflammation. Quantifying the mutual relationships of blood eosinophils, FE(NO), and serum periostin with sputum eosinophils by external validation in two independent cohorts across various severities of asthma. The first cohort consisted of 110 patients with mild to moderate asthma (external validation cohort). The replication cohort consisted of 37 patients with moderate to severe asthma. Both cohorts were evaluated cross-sectionally. Sputum was induced for the assessment of eosinophils. In parallel, blood eosinophil counts, serum periostin concentrations and FENO were assessed. The diagnostic accuracy of these markers to identify eosinophilic asthma (sputum eosinophils ≥3%) was calculated using receiver operating characteristics area under the curve (ROC AUC). In the external validation cohort, ROC AUC for blood eosinophils was 89% (peosinophilic from non-eosinophilic airway inflammation (ROC AUC=55%, p=0.44). When combining these three variables, no improvement was seen. The diagnostic value of blood eosinophils was confirmed in the replication cohort (ROC AUC 85%, peosinophils had the highest accuracy in the identification of sputum eosinophilia in asthma. The use of blood eosinophils can facilitate individualised treatment and management of asthma. NTR1846 and NTR2364. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  8. SU-F-R-04: Radiomics for Survival Prediction in Glioblastoma (GBM)

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, H; Molitoris, J; Bhooshan, N; Choi, W; Lu, W; Mehta, M; D’Souza, W [University of Maryland School of Medicine, Baltimore, MD (United States); Tan, S [Huazhong University of Science & Technology, Wuhan (China); Giacomelli, I; Scartoni, D [University of Florence, Florence (Italy); Gzell, C [Northern Sydney Cancer Centre, Sydney (Australia)

    2016-06-15

    Purpose: To develop a quantitative radiomics approach for survival prediction of glioblastoma (GBM) patients treated with chemoradiotherapy (CRT). Methods: 28 GBM patients who received CRT at our institution were retrospectively studied. 255 radiomic features were extracted from 3 gadolinium-enhanced T1 weighted MRIs for 2 regions of interest (ROIs) (the surgical cavity and its surrounding enhancement rim). The 3 MRIs were at pre-treatment, 1-month and 3-month post-CRT. The imaging features comprehensively quantified the intensity, spatial variation (texture), geometric property and their spatial-temporal changes for the 2 ROIs. 3 demographics features (age, race, gender) and 12 clinical parameters (KPS, extent of resection, whether concurrent temozolomide was adjusted/stopped and radiotherapy related information) were also included. 4 Machine learning models (logistic regression (LR), support vector machine (SVM), decision tree (DT), neural network (NN)) were applied to predict overall survival (OS) and progression-free survival (PFS). The number of cases and percentage of cases predicted correctly were collected and AUC (area under the receiver operating characteristic (ROC) curve) were determined after leave-one-out cross-validation. Results: From univariate analysis, 27 features (1 demographic, 1 clinical and 25 imaging) were statistically significant (p<0.05) for both OS and PFS. Two sets of features (each contained 24 features) were algorithmically selected from all features to predict OS and PFS. High prediction accuracy of OS was achieved by using NN (96%, 27 of 28 cases were correctly predicted, AUC = 0.99), LR (93%, 26 of 28 cases were correctly predicted, AUC = 0.95) and SVM (93%, 26 of 28 cases were correctly predicted, AUC = 0.90). When predicting PFS, NN obtained the highest prediction accuracy (89%, 25 of 28 cases were correctly predicted, AUC = 0.92). Conclusion: Radiomics approach combined with patients’ demographics and clinical parameters can

  9. High-accuracy interferometric measurements of flatness and parallelism of a step gauge

    CSIR Research Space (South Africa)

    Kruger, OA

    2001-01-01

    Full Text Available The most commonly used method in the calibration of step gauges is the coordinate measuring machine (CMM), equipped with a laser interferometer for the highest accuracy. This paper describes a modification to a length-bar measuring machine...

  10. AUC/MIC Pharmacodynamic Target Is Not a Good Predictor of Vancomycin Efficacy in Methicillin-Resistant Staphylococcus aureus Experimental Endocarditis.

    Science.gov (United States)

    Castañeda, Ximena; García-de-la-Mària, Cristina; Gasch, Oriol; Pericas, Juan M; Armero, Yolanda; Soy, Dolors; García-González, Javier; Falces, Carlos; Ninot, Salvador; Almela, Manel; Ambrosioni, Juan; Quintana, Eduardo; Vidal, Barbara; Fuster, David; Llopis, Jaume; Soto, Sara; Moreno, Asuncion; Marco, Francesc; Miró, Jose M

    2017-06-01

    The aim of this in vivo study was to compare the efficacy of vancomycin at standard doses (VAN-SD) to that of VAN at adjusted doses (VAN-AD) in achieving a VAN area under the curve/MIC ratio (AUC/MIC) of ≥400 against three methicillin-resistant Staphylococcus aureus (MRSA) strains with different microdilution VAN MICs in an experimental endocarditis model. The valve vegetation bacterial counts after 48 h of VAN therapy were compared, and no differences were observed between the two treatment groups for any of the three strains tested. Overall, for VAN-SD and VAN-AD, the rates of sterile vegetations were 15/45 (33.3%) and 21/49 (42.8%) ( P = 0.343), while the medians (interquartile ranges [IQRs]) for log 10 CFU/g of vegetation were 2 (0 to 6.9) and 2 (0 to 4.5) ( P = 0.384), respectively. In conclusion, this VAN AUC/MIC pharmacodynamic target was not a good predictor of vancomycin efficacy in MRSA experimental endocarditis. Copyright © 2017 American Society for Microbiology.

  11. Diagnostic accuracy of 18F-FDG-PET and PET/CT in the differential diagnosis between malignant and benign pleural lesions: a systematic review and meta-analysis.

    Science.gov (United States)

    Treglia, Giorgio; Sadeghi, Ramin; Annunziata, Salvatore; Lococo, Filippo; Cafarotti, Stefano; Bertagna, Francesco; Prior, John O; Ceriani, Luca; Giovanella, Luca

    2014-01-01

    To systematically review and meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the differential diagnosis between malignant and benign pleural lesions. A comprehensive literature search of studies published through June 2013 regarding the diagnostic performance of (18)F-FDG-PET and PET/CT in the differential diagnosis of pleural lesions was carried out. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odds ratio (DOR) of (18)F-FDG-PET or PET/CT in the differential diagnosis of pleural lesions on a per-patient-based analysis were calculated. The area under the summary receiver operating characteristic curve (AUC) was calculated to measure the accuracy of these methods. Subanalyses considering device used (PET or PET/CT) were performed. Sixteen studies including 745 patients were included in the systematic review. The meta-analysis of 11 selected studies provided the following results: sensitivity 95% (95% confidence interval [95%CI]: 92-97%), specificity 82% (95%CI: 76-88%), LR+ 5.3 (95%CI: 2.4-11.8), LR- 0.09 (95%CI: 0.05-0.14), DOR 74 (95%CI: 34-161). The AUC was 0.95. No significant improvement of the diagnostic accuracy considering PET/CT studies only was found. (18)F-FDG-PET and PET/CT demonstrated to be accurate diagnostic imaging methods in the differential diagnosis between malignant and benign pleural lesions; nevertheless, possible sources of false-negative and false-positive results should be kept in mind. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  12. To Predict the Requirement of Pharmacotherapy by OGTT Glucose Levels in Women with GDM Classified by the IADPSG Criteria

    Directory of Open Access Journals (Sweden)

    Gülen Yerlikaya

    2018-01-01

    Full Text Available The aim of this study was to assess the association between OGTT glucose levels and requirement of pharmacotherapy in GDM patients classified by the IADPSG criteria. This study included 203 GDM patients (108 managed with lifestyle modification and 95 requiring pharmacotherapy. Clinical risk factors and OGTT glucose concentrations at 0 (G0, 60 (G60, and 120 min (G120 were collected. OGTT glucose levels were significantly associated with the later requirement of pharmacotherapy (ROC-AUC: 71.1, 95% CI: 63.8–78.3. Also, the combination of clinical risk factors (age, BMI, parity, and pharmacotherapy in previous gestation showed an acceptable predictive accuracy (ROC-AUC: 72.1, 95% CI: 65.0–79.2, which was further improved when glycemic parameters were added (ROC-AUC: 77.5, 95% CI: 71.5–83.9. Random forest analysis revealed the highest variable importance for G0, G60, and age. OGTT glucose measures in addition to clinical risk factors showed promising properties for risk stratification in GDM patients classified by the recently established IADPSG criteria.

  13. Newly established ELISA for N-ERC/mesothelin improves diagnostic accuracy in patients with suspected pleural mesothelioma.

    Science.gov (United States)

    Sato, Tadashi; Suzuki, Yohei; Mori, Takanori; Maeda, Masahiro; Abe, Masaaki; Hino, Okio; Takahashi, Kazuhisa

    2014-10-01

    Pleural mesothelioma is an aggressive tumor, commonly caused by exposure to asbestos. The prognosis of mesothelioma remains disappointing despite multimodal treatment. We reported previously that N-ERC/mesothelin could be a useful biomarker for the early diagnosis of pleural mesothelioma and developed an enzyme-linked immunosorbent assay (ELISA) system for its detection. However, the reproducibility of our previous 7-16 ELISA system has been revealed to be unsatisfactory. To measure N-ERC/mesothelin more precisely, we developed a new 7-20 ELISA system. The subjects of this study were patients who were referred to our department with suspected pleural mesothelioma. The current study demonstrated that the newly established 7-20 ELISA system improved the sensitivity and specificity for diagnosing pleural mesothelioma compared with the previous system. Moreover, the 7-20 ELISA system showed better reproducibility and displayed the tendency of both higher sensitivity and higher specificity in plasma than in serum. Particularly for the epithelioid type, the area under the curve (AUC) and the diagnostic accuracy of N-ERC/mesothelin were excellent; the AUC was 0.91, the sensitivity was 0.95, and the specificity was 0.76 in plasma. In conclusion, assessment of N-ERC/mesothelin with our newly established 7-20 ELISA system is clinically useful for the precise diagnosis of pleural mesothelioma. © 2014 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  14. Detecting depressive and anxiety disorders in distressed patients in primary care; comparative diagnostic accuracy of the Four-Dimensional Symptom Questionnaire (4DSQ) and the Hospital Anxiety and Depression Scale (HADS).

    Science.gov (United States)

    Terluin, Berend; Brouwers, Evelien P M; van Marwijk, Harm W J; Verhaak, Peter F M; van der Horst, Henriëtte E

    2009-08-23

    Depressive and anxiety disorders often go unrecognized in distressed primary care patients, despite the overtly psychosocial nature of their demand for help. This is especially problematic in more severe disorders needing specific treatment (e.g. antidepressant pharmacotherapy or specialized cognitive behavioural therapy). The use of a screening tool to detect (more severe) depressive and anxiety disorders may be useful not to overlook such disorders. We examined the accuracy with which the Four-Dimensional Symptom Questionnaire (4DSQ) and the Hospital Anxiety and Depression Scale (HADS) are able to detect (more severe) depressive and anxiety disorders in distressed patients, and which cut-off points should be used. Seventy general practitioners (GPs) included 295 patients on sick leave due to psychological problems. They excluded patients with recognized depressive or anxiety disorders. Patients completed the 4DSQ and HADS. Standardized diagnoses of DSM-IV defined depressive and anxiety disorders were established with the Composite International Diagnostic Interview (CIDI). Receiver Operating Characteristic (ROC) analyses were performed to obtain sensitivity and specificity values for a range of scores, and area under the curve (AUC) values as a measure of diagnostic accuracy. With respect to the detection of any depressive or anxiety disorder (180 patients, 61%), the 4DSQ and HADS scales yielded comparable results with AUC values between 0.745 and 0.815. Also with respect to the detection of moderate or severe depressive disorder, the 4DSQ and HADS depression scales performed comparably (AUC 0.780 and 0.739, p 0.165). With respect to the detection of panic disorder, agoraphobia and social phobia, the 4DSQ anxiety scale performed significantly better than the HADS anxiety scale (AUC 0.852 versus 0.757, p 0.001). The recommended cut-off points of both HADS scales appeared to be too low while those of the 4DSQ anxiety scale appeared to be too high. In general

  15. INVESTIGATION THE FITTING ACCURACY OF CAST AND SLM CO-CR DENTAL BRIDGES USING CAD SOFTWARE

    Directory of Open Access Journals (Sweden)

    Tsanka Dikova

    2017-09-01

    Full Text Available The aim of the present paper is to investigate the fitting accuracy of Co-Cr dental bridges, manufactured by three technologies, with the newly developed method using CAD software. The four-part dental bridges of Co-Cr alloys were produced by conventional casting of wax models, casting with 3D printed patterns and selective laser melting. The marginal and internal fit of dental bridges was studied out by two methods – silicone replica test and CAD software. As the silicone replica test characterizes with comparatively low accuracy, a new methodology for investigating the fitting accuracy of dental bridges was developed based on the SolidWorks CAD software. The newly developed method allows the study of the marginal and internal adaptation in unlimited directions and high accuracy. Investigation the marginal fit and internal adaptation of Co-Cr four-part dental bridges by the two methods show that the technological process strongly influences the fitting accuracy of dental restorations. The fitting accuracy of the bridges, cast with 3D printed patterns, is the highest, followed by the SLM and conventionally cast bridges. The marginal fit of the three groups of bridges is in the clinically acceptable range. The internal gap values vary in different regions – it is highest on the occlusal surfaces, followed by that in the marginal and axial areas. The higher fitting accuracy of the bridges, manufactured by casting with 3D printed patterns and SLM, compared to the conventionally cast bridges is a good precondition for their successful implementation in the dental offices and laboratories.

  16. [Accuracy of computer aided measurement for detecting dental proximal caries lesions in images of cone-beam computed tomography].

    Science.gov (United States)

    Zhang, Z L; Li, J P; Li, G; Ma, X C

    2017-02-09

    Objective: To establish and validate a computer program used to aid the detection of dental proximal caries in the images cone beam computed tomography (CBCT) images. Methods: According to the characteristics of caries lesions in X-ray images, a computer aided detection program for proximal caries was established with Matlab and Visual C++. The whole process for caries lesion detection included image import and preprocessing, measuring average gray value of air area, choosing region of interest and calculating gray value, defining the caries areas. The program was used to examine 90 proximal surfaces from 45 extracted human teeth collected from Peking University School and Hospital of Stomatology. The teeth were then scanned with a CBCT scanner (Promax 3D). The proximal surfaces of the teeth were respectively detected by caries detection program and scored by human observer for the extent of lesions with 6-level-scale. With histologic examination serving as the reference standard, the caries detection program and the human observer performances were assessed with receiver operating characteristic (ROC) curves. Student t -test was used to analyze the areas under the ROC curves (AUC) for the differences between caries detection program and human observer. Spearman correlation coefficient was used to analyze the detection accuracy of caries depth. Results: For the diagnosis of proximal caries in CBCT images, the AUC values of human observers and caries detection program were 0.632 and 0.703, respectively. There was a statistically significant difference between the AUC values ( P= 0.023). The correlation between program performance and gold standard (correlation coefficient r (s)=0.525) was higher than that of observer performance and gold standard ( r (s)=0.457) and there was a statistically significant difference between the correlation coefficients ( P= 0.000). Conclusions: The program that automatically detects dental proximal caries lesions could improve the

  17. Diagnostic accuracy of liver fibrosis based on red cell distribution width (RDW) to platelet ratio with fibroscan in chronic hepatitis B

    Science.gov (United States)

    Sembiring, J.; Jones, F.

    2018-03-01

    Red cell Distribution Width (RDW) and platelet ratio (RPR) can predict liver fibrosis and cirrhosis in chronic hepatitis B with relatively high accuracy. RPR was superior to other non-invasive methods to predict liver fibrosis, such as AST and ALT ratio, AST and platelet ratio Index and FIB-4. The aim of this study was to assess diagnostic accuracy liver fibrosis by using RDW and platelets ratio in chronic hepatitis B patients based on compared with Fibroscan. This cross-sectional study was conducted at Adam Malik Hospital from January-June 2015. We examine 34 patients hepatitis B chronic, screen RDW, platelet, and fibroscan. Data were statistically analyzed. The result RPR with ROC procedure has an accuracy of 72.3% (95% CI: 84.1% - 97%). In this study, the RPR had a moderate ability to predict fibrosis degree (p = 0.029 with AUC> 70%). The cutoff value RPR was 0.0591, sensitivity and spesificity were 71.4% and 60%, Positive Prediction Value (PPV) was 55.6% and Negative Predictions Value (NPV) was 75%, positive likelihood ratio was 1.79 and negative likelihood ratio was 0.48. RPR have the ability to predict the degree of liver fibrosis in chronic hepatitis B patients with moderate accuracy.

  18. Role of MRI in detecting involvement of the uterine internal os in uterine cervical cancer: Systematic review of diagnostic test accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Boer, Peter de, E-mail: p.deboer@amc.uva.nl [Department of Radiation Oncology, Academic Medical Centre (AMC), University of Amsterdam (UvA), Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Adam, Judit A. [Department of Radiology, AMC, UvA (Netherlands); Department of Nuclear Medicine, AMC, UvA (Netherlands); Buist, Marrije R. [Department of Gynaecology and Obstetrics, AMC, UvA (Netherlands); Vijver, Marc J. van de [Department of Pathology, AMC, UvA (Netherlands); Rasch, Coen R. [Department of Radiation Oncology, Academic Medical Centre (AMC), University of Amsterdam (UvA), Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Stoker, Jaap; Bipat, Shandra [Department of Radiology, AMC, UvA (Netherlands); Stalpers, Lukas J.A. [Department of Radiation Oncology, Academic Medical Centre (AMC), University of Amsterdam (UvA), Meibergdreef 9, 1105 AZ Amsterdam (Netherlands)

    2013-09-15

    Purpose: In patients with uterine cervical cancer, pretreatment recognition of uterine extension is crucial in treatment decision-making for fertility-sparing surgery and for target delineation in radiotherapy. Although MRI is generally considered the most reliable method, its value for detecting involvement of the uterine internal os is unclear. Methods: Medline, Embase and Cochrane databases were systematically searched (January 1997–December 2012) for MRI studies that measured the accuracy of involvement of the uterine internal os compared to histopathology as reference standard in patients with uterine cervical cancer. Data were assessed using the QUADAS tool. Accuracy concerned either involvement (yes/no) of the uterine internal os, or measuring invasion distance toward the uterine corpus. Results: Two retrospective and two prospective studies described 366 patients diagnosed with uterine cervical cancer FIGO stage IIB or below, in whom 64 (17%) had uterine internal os involvement. For three studies the summary estimates of specificity, sensitivity, negative predictive value (NPV), positive predictive value (PPV), and accuracy were 91%, 97%, 99%, 79% and 95%, respectively; one study had an area under the curve (AUC) of 0.8. Conclusion: MRI has a high level of accuracy; however, data are limited and for validation a large prospective study is needed that compares actual measurements on MRI with histopathological examination.

  19. Camera sensor arrangement for crop/weed detection accuracy in agronomic images.

    Science.gov (United States)

    Romeo, Juan; Guerrero, José Miguel; Montalvo, Martín; Emmi, Luis; Guijarro, María; Gonzalez-de-Santos, Pablo; Pajares, Gonzalo

    2013-04-02

    In Precision Agriculture, images coming from camera-based sensors are commonly used for weed identification and crop line detection, either to apply specific treatments or for vehicle guidance purposes. Accuracy of identification and detection is an important issue to be addressed in image processing. There are two main types of parameters affecting the accuracy of the images, namely: (a) extrinsic, related to the sensor's positioning in the tractor; (b) intrinsic, related to the sensor specifications, such as CCD resolution, focal length or iris aperture, among others. Moreover, in agricultural applications, the uncontrolled illumination, existing in outdoor environments, is also an important factor affecting the image accuracy. This paper is exclusively focused on two main issues, always with the goal to achieve the highest image accuracy in Precision Agriculture applications, making the following two main contributions: (a) camera sensor arrangement, to adjust extrinsic parameters and (b) design of strategies for controlling the adverse illumination effects.

  20. Highest energy cosmic rays

    International Nuclear Information System (INIS)

    Nikolskij, S.

    1984-01-01

    Primary particles of cosmic radiation with highest energies cannot in view of their low intensity be recorded directly but for this purpose the phenomenon is used that these particles interact with nuclei in the atmosphere and give rise to what are known as extensive air showers. It was found that 40% of primary particles with an energy of 10 15 to 10 16 eV consist of protons, 12 to 15% of helium nuclei, 15% of iron nuclei, the rest of nuclei of other elements. Radiation intensity with an energy of 10 18 to 10 19 eV depends on the direction of incoming particles. Maximum intensity is in the direction of the centre of the nearest clustre of galaxies, minimal in the direction of the central area of our galaxy. (Ha)

  1. Accuracy Assessment of Different Digital Surface Models

    Directory of Open Access Journals (Sweden)

    Ugur Alganci

    2018-03-01

    -sections were extracted from the DSMs to evaluate the accuracies related to land cover. The PHR and SPOT DSMs had the highest accuracies of all of the testing methods, followed by the ALOS DSM, which had very promising results. Comparatively, the SRTM and ASTER DSMs had the worst accuracies. Additionally, the PHR and SPOT DSMs captured man-made objects and above-terrain structures, which indicated the need for post-processing to attain better representations.

  2. Accuracy of the Spot and Plusoptix photoscreeners for detection of astigmatism.

    Science.gov (United States)

    Crescioni, Mabel; Miller, Joseph M; Harvey, Erin M

    2015-10-01

    To evaluate the accuracy of the Spot (V2.0.16) and Plusoptix S12 (ROC4, V6.1.4.0) photoscreeners in detecting astigmatism meeting AAPOS referral criteria in students from a population with high prevalence of astigmatism. Students attending grades 3-8 on the Tohono O'odham reservation were examined. Screening was attempted with both the Spot and Plusoptix photoscreeners. Results were compared to cycloplegic refraction. Screening attempts providing no estimate of refractive error were considered fail/refer. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for detection of refractive errors were determined using AAPOS referral criteria and receiver operating characteristic area under the curve (ROC AUC) analysis was conducted for measures of astigmatism. Agreement between screening and cycloplegic refraction measurements of astigmatism, spherical equivalent, and anisometropia were assessed using t tests and correlation analyses. A total of 209 students were included. Of the total, 116 (55%) met examination-positive criteria based on cycloplegic refraction, with 105 of those (90%) meeting the criterion for astigmatism. Measurements success rates were 97% for Spot and 54% for Plusoptix. Comparing the Spot and the Plusoptix, sensitivity was 96% versus 100%, specificity was 87% versus 61%, PPV was 90% versus 76%, and NPV was 94% versus 100% for detection of refractive error. Both screeners overestimated astigmatism by 1/3 D to 2/3 D. AUC for astigmatism was 0.97 for Spot and 0.83 for Plusoptix. In this highly astigmatic population, the Spot and the Plusoptix had similar sensitivity, but the Spot had better specificity and measurement success rates. Compared with results from study samples with lower rates of astigmatism, our results highlight the need to assess the ability of screening instruments to detect individual types of refractive errors. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus

  3. Deep Learning Accurately Predicts Estrogen Receptor Status in Breast Cancer Metabolomics Data.

    Science.gov (United States)

    Alakwaa, Fadhl M; Chaudhary, Kumardeep; Garmire, Lana X

    2018-01-05

    Metabolomics holds the promise as a new technology to diagnose highly heterogeneous diseases. Conventionally, metabolomics data analysis for diagnosis is done using various statistical and machine learning based classification methods. However, it remains unknown if deep neural network, a class of increasingly popular machine learning methods, is suitable to classify metabolomics data. Here we use a cohort of 271 breast cancer tissues, 204 positive estrogen receptor (ER+), and 67 negative estrogen receptor (ER-) to test the accuracies of feed-forward networks, a deep learning (DL) framework, as well as six widely used machine learning models, namely random forest (RF), support vector machines (SVM), recursive partitioning and regression trees (RPART), linear discriminant analysis (LDA), prediction analysis for microarrays (PAM), and generalized boosted models (GBM). DL framework has the highest area under the curve (AUC) of 0.93 in classifying ER+/ER- patients, compared to the other six machine learning algorithms. Furthermore, the biological interpretation of the first hidden layer reveals eight commonly enriched significant metabolomics pathways (adjusted P-value learning methods. Among them, protein digestion and absorption and ATP-binding cassette (ABC) transporters pathways are also confirmed in integrated analysis between metabolomics and gene expression data in these samples. In summary, deep learning method shows advantages for metabolomics based breast cancer ER status classification, with both the highest prediction accuracy (AUC = 0.93) and better revelation of disease biology. We encourage the adoption of feed-forward networks based deep learning method in the metabolomics research community for classification.

  4. PENERAPAN TEKNIK BAGGING PADA ALGORITMA KLASIFIKASI UNTUK MENGATASI KETIDAKSEIMBANGAN KELAS DATASET MEDIS

    Directory of Open Access Journals (Sweden)

    Rizki Tri Prasetio

    2016-03-01

    Full Text Available ABSTRACT – The class imbalance problems have been reported to severely hinder classification performance of many standard learning algorithms, and have attracted a great deal of attention from researchers of different fields. Therefore, a number of methods, such as sampling methods, cost-sensitive learning methods, and bagging and boosting based ensemble methods, have been proposed to solve these problems. Some medical dataset has two classes has two classes or binominal experiencing an imbalance that causes lack of accuracy in classification. This research proposed a combination technique of bagging and algorithms of classification to improve the accuracy of medical datasets. Bagging technique used to solve the problem of imbalanced class. The proposed method is applied on three classifier algorithm i.e., naïve bayes, decision tree and k-nearest neighbor. This research uses five medical datasets obtained from UCI Machine Learning i.e.., breast-cancer, liver-disorder, heart-disease, pima-diabetes and vertebral column. Results of this research indicate that the proposed method makes a significant improvement on two algorithms of classification i.e. decision tree with p value of t-Test 0.0184 and k-nearest neighbor with p value of t-Test 0.0292, but not significant in naïve bayes with p value of t-Test 0.9236. After bagging technique applied at five medical datasets, naïve bayes has the highest accuracy for breast-cancer dataset of 96.14% with AUC of 0.984, heart-disease of 84.44% with AUC of 0.911 and pima-diabetes of 74.73% with AUC of 0.806. While the k-nearest neighbor has the best accuracy for dataset liver-disorder of 62.03% with AUC of 0.632 and vertebral-column of 82.26% with the AUC of 0.867. Keywords: ensemble technique, bagging, imbalanced class, medical dataset. ABSTRAKSI – Masalah ketidakseimbangan kelas telah dilaporkan sangat menghambat kinerja klasifikasi banyak algoritma klasifikasi dan telah menarik banyak perhatian dari

  5. Evaluating the predictive abilities of community occupancy models using AUC while accounting for imperfect detection

    Science.gov (United States)

    Zipkin, Elise F.; Grant, Evan H. Campbell; Fagan, William F.

    2012-01-01

    The ability to accurately predict patterns of species' occurrences is fundamental to the successful management of animal communities. To determine optimal management strategies, it is essential to understand species-habitat relationships and how species habitat use is related to natural or human-induced environmental changes. Using five years of monitoring data in the Chesapeake and Ohio Canal National Historical Park, Maryland, USA, we developed four multi-species hierarchical models for estimating amphibian wetland use that account for imperfect detection during sampling. The models were designed to determine which factors (wetland habitat characteristics, annual trend effects, spring/summer precipitation, and previous wetland occupancy) were most important for predicting future habitat use. We used the models to make predictions of species occurrences in sampled and unsampled wetlands and evaluated model projections using additional data. Using a Bayesian approach, we calculated a posterior distribution of receiver operating characteristic area under the curve (ROC AUC) values, which allowed us to explicitly quantify the uncertainty in the quality of our predictions and to account for false negatives in the evaluation dataset. We found that wetland hydroperiod (the length of time that a wetland holds water) as well as the occurrence state in the prior year were generally the most important factors in determining occupancy. The model with only habitat covariates predicted species occurrences well; however, knowledge of wetland use in the previous year significantly improved predictive ability at the community level and for two of 12 species/species complexes. Our results demonstrate the utility of multi-species models for understanding which factors affect species habitat use of an entire community (of species) and provide an improved methodology using AUC that is helpful for quantifying the uncertainty in model predictions while explicitly accounting for

  6. Excellent AUC for joint fluid cytology in the detection/exclusion of hip and knee prosthetic joint infection.

    Science.gov (United States)

    Gallo, Jiri; Juranova, Jarmila; Svoboda, Michal; Zapletalova, Jana

    2017-09-01

    The aim of this study was to evaluate the characteristics of synovial fluid (SF) white cell count (SWCC) and neutrophil/lymphocyte percentage in the diagnosis of prosthetic joint infection (PJI) for particular threshold values. This was a prospective study of 391 patients in whom SF specimens were collected before total joint replacement revisions. SF was aspirated before joint capsule incision. The PJI diagnosis was based only on non-SF data. Receiver operating characteristic plots were constructed for the SWCC and differential counts of leukocytes in aspirated fluid. Logistic binomic regression was used to distinguish infected and non-infected cases in the combined data. PJI was diagnosed in 78 patients, and aseptic revision in 313 patients. The areas (AUC) under the curve for the SWCC, the neutrophil and lymphocyte percentages were 0.974, 0.962, and 0.951, respectively. The optimal cut-off for PJI was 3,450 cells/μL, 74.6% neutrophils, and 14.6% lymphocytes. Positive likelihood ratios for the SWCC, neutrophil and lymphocyte percentages were 19.0, 10.4, and 9.5, respectively. Negative likelihood ratios for the SWCC, neutrophil and lymphocyte percentages were 0.06, 0.076, and 0.092, respectively. Based on AUC, the present study identified cut-off values for the SWCC and differential leukocyte count for the diagnosis of PJI. The likelihood ratio for positive/negative SWCCs can significantly change the pre-test probability of PJI.

  7. Innovative preparation of Au/C by replication of gold-containing mesoporous silica catalysts

    KAUST Repository

    Kerdi, Fatmé

    2010-01-01

    A new strategy, based on the nanocasting concept, has been used to prepare gold nanoparticles (NPs) highly dispersed in meso-structured carbons. Gold is first introduced in various functionalized mesostructured silicas (MCM-48 and SBA-15) and particles are formed inside the porosity upon reduction of Au 3+ cations. Silica pores are then impregnated with a carbon precursor and the composite material is heated at 900°C under vacuum. Silica is then removed by acid leaching, leading to partially encapsulated gold particles in mesoporous carbon. Carbon prevents aggregation of gold particles at high temperature, both the mean size and distribution being similar to those observed in silica. However, while Au@SiO2 exhibit significant catalytic activity in the aerobic oxidation of trans-stilbene in the liquid phase, its Au@C mesostructured replica is quite inactive. © 2010 Elsevier B.V. All rights reserved.

  8. Three novel obese indicators perform better in monitoring management of metabolic syndrome in type 2 diabetes.

    Science.gov (United States)

    Ma, Chun-Ming; Lu, Na; Wang, Rui; Liu, Xiao-Li; Lu, Qiang; Yin, Fu-Zai

    2017-08-29

    The present study evaluated the performance of three novel obese indicators, visceral adiposity index (VAI), lipid accumulation product (LAP) and waist circumference-triglyceride index (WTI), for identifying metabolic syndrome(MetS) in type 2 diabetes. A cross-sectional study was conducted on 711 type 2 diabetes in Qinhuangdao. The MetS was defined as the definition of Chinese Diabetes Society. Receiver operating characteristic curve analyses were performed to assess the accuracy of three obese indicators as diagnostic tests for MetS. The prevalence of MetS was 71.3%. In men, among all three obese indicators, the LAP had the highest area under curve (AUC) value (AUC = 0.894), followed by VAI (AUC = 0.860) and WTI (AUC = 0.855). In women, among all three obese indicators, the LAP had the highest AUC value (AUC = 0.906), followed by WTI (AUC = 0.887) and VAI (AUC = 0.881). However. there was no significant difference between the three obese indicators(P > 0.05). Three obese indicators were effective indicators for the screening of MetS, LAP and WTI are more simple.

  9. Detecting depressive and anxiety disorders in distressed patients in primary care; comparative diagnostic accuracy of the Four-Dimensional Symptom Questionnaire (4DSQ and the Hospital Anxiety and Depression Scale (HADS

    Directory of Open Access Journals (Sweden)

    Verhaak Peter FM

    2009-08-01

    Full Text Available Abstract Background Depressive and anxiety disorders often go unrecognized in distressed primary care patients, despite the overtly psychosocial nature of their demand for help. This is especially problematic in more severe disorders needing specific treatment (e.g. antidepressant pharmacotherapy or specialized cognitive behavioural therapy. The use of a screening tool to detect (more severe depressive and anxiety disorders may be useful not to overlook such disorders. We examined the accuracy with which the Four-Dimensional Symptom Questionnaire (4DSQ and the Hospital Anxiety and Depression Scale (HADS are able to detect (more severe depressive and anxiety disorders in distressed patients, and which cut-off points should be used. Methods Seventy general practitioners (GPs included 295 patients on sick leave due to psychological problems. They excluded patients with recognized depressive or anxiety disorders. Patients completed the 4DSQ and HADS. Standardized diagnoses of DSM-IV defined depressive and anxiety disorders were established with the Composite International Diagnostic Interview (CIDI. Receiver Operating Characteristic (ROC analyses were performed to obtain sensitivity and specificity values for a range of scores, and area under the curve (AUC values as a measure of diagnostic accuracy. Results With respect to the detection of any depressive or anxiety disorder (180 patients, 61%, the 4DSQ and HADS scales yielded comparable results with AUC values between 0.745 and 0.815. Also with respect to the detection of moderate or severe depressive disorder, the 4DSQ and HADS depression scales performed comparably (AUC 0.780 and 0.739, p 0.165. With respect to the detection of panic disorder, agoraphobia and social phobia, the 4DSQ anxiety scale performed significantly better than the HADS anxiety scale (AUC 0.852 versus 0.757, p 0.001. The recommended cut-off points of both HADS scales appeared to be too low while those of the 4DSQ anxiety

  10. Diagnostic accuracy of indirect laryngoscopy and x-ray neck in the diagnosis of fish bone impaction in upper aero digestive tract

    International Nuclear Information System (INIS)

    Kundi, N.; Mehmood, T.

    2015-01-01

    This study was aimed at finding the validity of indirect laryngoscopy (IDL) and neck X-Rays in the diagnosis of fish bone impaction. Study Design: Validation study. Place and Duration of Study: CMH Nowshera from August 2012 to February 2013. Material and Methods: A total of 50 patients were selected by consecutive sampling presenting with history of fishbone impaction in aerodigestive tract. IDL examination and neck X-rays were performed and findings were recorded. Those with no fishbone on both the investigations were discharged from hospital with follow up after 03 days. Those with fishbone detected on either of investigations underwent removal. Fishbone easily approachable were removed under local anaesthesia with foreceps and in others Endoscopy (Direct laryngoscopy or Oesophagoscopy) was performed under General Anaesthesia. Sensitivities and specificities of both the modalities were calculated using standard 2/2 Table. ROC curve analysis was carried out and significance level p < 0.05 was taken as significant. Results: In 20 patients no fishbone was found, 26 patients were diagnosed on IDL and in 04 patients fishbone was detected by neck X-Rays. Most common site for fishbone impaction was pharyngeal tonsil. In 22 patients fishbone was removed with foreceps and in 08 patients endoscopy was performed. Diagnostic accuracy for IDL 86% and Neck X-Rays 48% was calculated. ROC curve analysis revealed AUC for IDL 0.933 and Significance level (P) as <0.0001. ROC curve analysis for X-ray gives AUC of 0.567 and Significance level (p) 0.4132. Conclusion: IDL shows higher diagnostic accuracy than neck X-Rays for detection of fishbone in upper aerodigestive tract. Neck X-rays are more useful for impacted foreign bodies in oesophagus. (author)

  11. Ammonium uranyl carbonate (AUC) based process of simultaneous partitioning and reconversion for uranium and plutonium in fast breeder reactors (FBRs) fuel reprocessing

    International Nuclear Information System (INIS)

    Govindan, P.; Palamalai, A.; Vijayan, K.S.; Subba Rao, R.V.; Venkataraman, M.; Natarajan, R.

    2013-01-01

    Ammonium uranyl carbonate (AUC) based process of simultaneous partitioning and reconversion for uranium and plutonium is developed for the recovery of uranium and plutonium present in spent fuel of fast breeder reactors (FBRs). Effect of pH on the solubility of carbonates of uranium and plutonium in ammonium carbonate medium is studied. Effect of mole ratios of uranium and plutonium as a function of uranium and plutonium concentration at pH 8.0-8.5 for effective separation of uranium and plutonium to each other is studied. Feasibility of reconversion of plutonium in carbonate medium is also studied. The studies indicate that uranium is selectively precipitated as AUC at pH 8.0-8.5 by adding ammonium carbonate solution leaving plutonium in the filtrate. Plutonium in the filtrate after acidified with concentrated nitric acid could also be precipitated as carbonate at pH 6.5-7.0 by adding ammonium carbonate solution. A flow sheet is proposed and evaluated for partitioning and reconversion of uranium and plutonium simultaneously in the FBR fuel reprocessing. (author)

  12. Diagnostic value of ST-segment deviations during cardiac exercise stress testing: Systematic comparison of different ECG leads and time-points.

    Science.gov (United States)

    Puelacher, Christian; Wagener, Max; Abächerli, Roger; Honegger, Ursina; Lhasam, Nundsin; Schaerli, Nicolas; Prêtre, Gil; Strebel, Ivo; Twerenbold, Raphael; Boeddinghaus, Jasper; Nestelberger, Thomas; Rubini Giménez, Maria; Hillinger, Petra; Wildi, Karin; Sabti, Zaid; Badertscher, Patrick; Cupa, Janosch; Kozhuharov, Nikola; du Fay de Lavallaz, Jeanne; Freese, Michael; Roux, Isabelle; Lohrmann, Jens; Leber, Remo; Osswald, Stefan; Wild, Damian; Zellweger, Michael J; Mueller, Christian; Reichlin, Tobias

    2017-07-01

    Exercise ECG stress testing is the most widely available method for evaluation of patients with suspected myocardial ischemia. Its major limitation is the relatively poor accuracy of ST-segment changes regarding ischemia detection. Little is known about the optimal method to assess ST-deviations. A total of 1558 consecutive patients undergoing bicycle exercise stress myocardial perfusion imaging (MPI) were enrolled. Presence of inducible myocardial ischemia was adjudicated using MPI results. The diagnostic value of ST-deviations for detection of exercise-induced myocardial ischemia was systematically analyzed 1) for each individual lead, 2) at three different intervals after the J-point (J+40ms, J+60ms, J+80ms), and 3) at different time points during the test (baseline, maximal workload, 2min into recovery). Exercise-induced ischemia was detected in 481 (31%) patients. The diagnostic accuracy of ST-deviations was highest at +80ms after the J-point, and at 2min into recovery. At this point, ST-amplitude showed an AUC of 0.63 (95% CI 0.59-0.66) for the best-performing lead I. The combination of ST-amplitude and ST-slope in lead I did not increase the AUC. Lead I reached a sensitivity of 37% and a specificity of 83%, with similar sensitivity to manual ECG analysis (34%, p=0.31) but lower specificity (90%, pST-deviations is highest when evaluated at +80ms after the J-point, and at 2min into recovery. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Accuracy of five intraoral scanners compared to indirect digitalization.

    Science.gov (United States)

    Güth, Jan-Frederik; Runkel, Cornelius; Beuer, Florian; Stimmelmayr, Michael; Edelhoff, Daniel; Keul, Christine

    2017-06-01

    Direct and indirect digitalization offer two options for computer-aided design (CAD)/ computer-aided manufacturing (CAM)-generated restorations. The aim of this study was to evaluate the accuracy of different intraoral scanners and compare them to the process of indirect digitalization. A titanium testing model was directly digitized 12 times with each intraoral scanner: (1) CS 3500 (CS), (2) Zfx Intrascan (ZFX), (3) CEREC AC Bluecam (BLU), (4) CEREC AC Omnicam (OC) and (5) True Definition (TD). As control, 12 polyether impressions were taken and the referring plaster casts were digitized indirectly with the D-810 laboratory scanner (CON). The accuracy (trueness/precision) of the datasets was evaluated by an analysing software (Geomagic Qualify 12.1) using a "best fit alignment" of the datasets with a highly accurate reference dataset of the testing model, received from industrial computed tomography. Direct digitalization using the TD showed the significant highest overall "trueness", followed by CS. Both performed better than CON. BLU, ZFX and OC showed higher differences from the reference dataset than CON. Regarding the overall "precision", the CS 3500 intraoral scanner and the True Definition showed the best performance. CON, BLU and OC resulted in significantly higher precision than ZFX did. Within the limitations of this in vitro study, the accuracy of the ascertained datasets was dependent on the scanning system. The direct digitalization was not superior to indirect digitalization for all tested systems. Regarding the accuracy, all tested intraoral scanning technologies seem to be able to reproduce a single quadrant within clinical acceptable accuracy. However, differences were detected between the tested systems.

  14. Which Kids Are at Highest Risk for Suicide?

    Science.gov (United States)

    ... Share Which Kids are at Highest Risk for Suicide? Page Content Article Body No child is immune, ... who have lost a friend or relative to suicide. Studies show that a considerable number of youth ...

  15. [Forest lighting fire forecasting for Daxing'anling Mountains based on MAXENT model].

    Science.gov (United States)

    Sun, Yu; Shi, Ming-Chang; Peng, Huan; Zhu, Pei-Lin; Liu, Si-Lin; Wu, Shi-Lei; He, Cheng; Chen, Feng

    2014-04-01

    Daxing'anling Mountains is one of the areas with the highest occurrence of forest lighting fire in Heilongjiang Province, and developing a lightning fire forecast model to accurately predict the forest fires in this area is of importance. Based on the data of forest lightning fires and environment variables, the MAXENT model was used to predict the lightning fire in Daxing' anling region. Firstly, we studied the collinear diagnostic of each environment variable, evaluated the importance of the environmental variables using training gain and the Jackknife method, and then evaluated the prediction accuracy of the MAXENT model using the max Kappa value and the AUC value. The results showed that the variance inflation factor (VIF) values of lightning energy and neutralized charge were 5.012 and 6.230, respectively. They were collinear with the other variables, so the model could not be used for training. Daily rainfall, the number of cloud-to-ground lightning, and current intensity of cloud-to-ground lightning were the three most important factors affecting the lightning fires in the forest, while the daily average wind speed and the slope was of less importance. With the increase of the proportion of test data, the max Kappa and AUC values were increased. The max Kappa values were above 0.75 and the average value was 0.772, while all of the AUC values were above 0.5 and the average value was 0. 859. With a moderate level of prediction accuracy being achieved, the MAXENT model could be used to predict forest lightning fire in Daxing'anling Mountains.

  16. Quantitative differentiation of breast lesions at 3T diffusion-weighted imaging (DWI) using the ratio of distributed diffusion coefficient (DDC).

    Science.gov (United States)

    Ertas, Gokhan; Onaygil, Can; Akin, Yasin; Kaya, Handan; Aribal, Erkin

    2016-12-01

    To investigate the accuracy of diffusion coefficients and diffusion coefficient ratios of breast lesions and of glandular breast tissue from mono- and stretched-exponential models for quantitative diagnosis in diffusion-weighted magnetic resonance imaging (MRI). We analyzed pathologically confirmed 170 lesions (85 benign and 85 malignant) imaged using a 3.0T MR scanner. Small regions of interest (ROIs) focusing on the highest signal intensity for lesions and also for glandular tissue of contralateral breast were obtained. Apparent diffusion coefficient (ADC) and distributed diffusion coefficient (DDC) were estimated by performing nonlinear fittings using mono- and stretched-exponential models, respectively. Coefficient ratios were calculated by dividing the lesion coefficient by the glandular tissue coefficient. A stretched exponential model provides significantly better fits then the monoexponential model (P DDC ratio (area under the curve [AUC] = 0.93) when compared with lesion DDC, ADC ratio, and lesion ADC (AUC = 0.91, 0.90, 0.90) but with no statistically significant difference (P > 0.05). At optimal thresholds, the DDC ratio achieves 93% sensitivity, 80% specificity, and 87% overall diagnostic accuracy, while ADC ratio leads to 89% sensitivity, 78% specificity, and 83% overall diagnostic accuracy. The stretched exponential model fits better with signal intensity measurements from both lesion and glandular tissue ROIs. Although the DDC ratio estimated by using the model shows a higher diagnostic accuracy than the ADC ratio, lesion DDC, and ADC, it is not statistically significant. J. Magn. Reson. Imaging 2016;44:1633-1641. © 2016 International Society for Magnetic Resonance in Medicine.

  17. Cortex Matures Faster in Youths With Highest IQ

    Science.gov (United States)

    ... NIH Cortex Matures Faster in Youths With Highest IQ Past Issues / Summer 2006 Table of Contents For ... on. Photo: Getty image (StockDisc) Youths with superior IQ are distinguished by how fast the thinking part ...

  18. Finish line distinctness and accuracy in 7 intraoral scanners versus conventional impression: an in vitro descriptive comparison.

    Science.gov (United States)

    Nedelcu, Robert; Olsson, Pontus; Nyström, Ingela; Thor, Andreas

    2018-02-23

    Several studies have evaluated accuracy of intraoral scanners (IOS), but data is lacking regarding variations between IOS systems in the depiction of the critical finish line and the finish line accuracy. The aim of this study was to analyze the level of finish line distinctness (FLD), and finish line accuracy (FLA), in 7 intraoral scanners (IOS) and one conventional impression (IMPR). Furthermore, to assess parameters of resolution, tessellation, topography, and color. A dental model with a crown preparation including supra and subgingival finish line was reference-scanned with an industrial scanner (ATOS), and scanned with seven IOS: 3M, CS3500 and CS3600, DWIO, Omnicam, Planscan and Trios. An IMPR was taken and poured, and the model was scanned with a laboratory scanner. The ATOS scan was cropped at finish line and best-fit aligned for 3D Compare Analysis (Geomagic). Accuracy was visualized, and descriptive analysis was performed. All IOS, except Planscan, had comparable overall accuracy, however, FLD and FLA varied substantially. Trios presented the highest FLD, and with CS3600, the highest FLA. 3M, and DWIO had low overall FLD and low FLA in subgingival areas, whilst Planscan had overall low FLD and FLA, as well as lower general accuracy. IMPR presented high FLD, except in subgingival areas, and high FLA. Trios had the highest resolution by factor 1.6 to 3.1 among IOS, followed by IMPR, DWIO, Omnicam, CS3500, 3M, CS3600 and Planscan. Tessellation was found to be non-uniform except in 3M and DWIO. Topographic variation was found for 3M and Trios, with deviations below +/- 25 μm for Trios. Inclusion of color enhanced the identification of the finish line in Trios, Omnicam and CS3600, but not in Planscan. There were sizeable variations between IOS with both higher and lower FLD and FLA than IMPR. High FLD was more related to high localized finish line resolution and non-uniform tessellation, than to high overall resolution. Topography variations were low

  19. Reconstrucción de las redes sociales: el caso de las FARC, el ELN y las ACCU-AUC

    Directory of Open Access Journals (Sweden)

    Plata Caviedes, Juan Camilo

    2006-06-01

    Full Text Available It is explored a strategy to analyze the press releases made by the FARC, the ELN, and the ACCU-AUC. It is based on the minimal grammatical structure: Subject- Action - Object. Using this grammatical triplet, the network of connections are built up; and then, some of the Social Network Analysis tools are applied to it. Some mechanisms related with these structural properties are identified: a To define for each actor a distinctive set of relationships; b the part is different from the whole; c the emphasized topics do the work of putting near a set of nodes.

  20. Highest priority in Pakistan.

    Science.gov (United States)

    Adil, E

    1968-01-01

    Responding to the challenge posed by its population problem, Pakistan's national leadership gave the highest priority to family planning in its socioeconomic development plan. In Pakistan, as elsewhere in the world, the first family planning effort originated in the private sector. The Family Planning Association of Pakistan made a tentative beginning in popularizing family planning in the country. Some clinics were opened and some publicity and education were undertaken to emphasize the need for family limitation. It was recognized soon that the government needed to assume the primarily responsibility if family planning efforts were to be successful. For the 1st plan period, 1955-60, about $10 million was allocated by the central government in the social welfare sector for voluntary family planning. The level of support continued on the same basis during the 2nd plan, 1960-65, but has been raised 4-fold in the 1965-70 scheme of family planning. Pakistan's Family Planning Association continues to play vital collaborative roles in designing and pretesting of prototype publicity material, involvement of voluntary social workers, and functional research in the clinical and public relations fields. The real breakthrough in the program came with the 3rd 5-year plan, 1965-70. High priority assigned to family planning is reflected by the total initial budget of Rs.284 million (about $60,000,000) for the 5-year period. Current policy is postulated on 6 basic assumptions: family planning efforts need to be public relations-oriented; operations should be conducted through autonomous bodies with decentralized authority at all tiers down to the grassroots level, for expeditious decision making; monetary incentives play an important role; interpersonal motivation in terms of life experience of the clientele through various contacts, coupled with mass media for publicity, can produce a sociological breakthrough; supplies and services in all related disciplines should be

  1. Prediction of Adulthood Obesity Using Genetic and Childhood Clinical Risk Factors in the Cardiovascular Risk in Young Finns Study.

    Science.gov (United States)

    Seyednasrollah, Fatemeh; Mäkelä, Johanna; Pitkänen, Niina; Juonala, Markus; Hutri-Kähönen, Nina; Lehtimäki, Terho; Viikari, Jorma; Kelly, Tanika; Li, Changwei; Bazzano, Lydia; Elo, Laura L; Raitakari, Olli T

    2017-06-01

    Obesity is a known risk factor for cardiovascular disease. Early prediction of obesity is essential for prevention. The aim of this study is to assess the use of childhood clinical factors and the genetic risk factors in predicting adulthood obesity using machine learning methods. A total of 2262 participants from the Cardiovascular Risk in YFS (Young Finns Study) were followed up from childhood (age 3-18 years) to adulthood for 31 years. The data were divided into training (n=1625) and validation (n=637) set. The effect of known genetic risk factors (97 single-nucleotide polymorphisms) was investigated as a weighted genetic risk score of all 97 single-nucleotide polymorphisms (WGRS97) or a subset of 19 most significant single-nucleotide polymorphisms (WGRS19) using boosting machine learning technique. WGRS97 and WGRS19 were validated using external data (n=369) from BHS (Bogalusa Heart Study). WGRS19 improved the accuracy of predicting adulthood obesity in training (area under the curve [AUC=0.787 versus AUC=0.744, P obesity. Predictive accuracy is highest among young children (3-6 years), whereas among older children (9-18 years) the risk can be identified using childhood clinical factors. The model is helpful in screening children with high risk of developing obesity. © 2017 American Heart Association, Inc.

  2. Data mining in bone marrow transplant records to identify patients with high odds of survival.

    Science.gov (United States)

    Taati, Babak; Snoek, Jasper; Aleman, Dionne; Ghavamzadeh, Ardeshir

    2014-01-01

    Patients undergoing a bone marrow stem cell transplant (BMT) face various risk factors. Analyzing data from past transplants could enhance the understanding of the factors influencing success. Records up to 120 measurements per transplant procedure from 1751 patients undergoing BMT were collected (Shariati Hospital). Collaborative filtering techniques allowed the processing of highly sparse records with 22.3% missing values. Ten-fold cross-validation was used to evaluate the performance of various classification algorithms trained on predicting the survival status. Modest accuracy levels were obtained in predicting the survival status (AUC = 0.69). More importantly, however, operations that had the highest chances of success were shown to be identifiable with high accuracy, e.g., 92% or 97% when identifying 74 or 31 recipients, respectively. Identifying the patients with the highest chances of survival has direct application in the prioritization of resources and in donor matching. For patients where high-confidence prediction is not achieved, assigning a probability to their survival odds has potential applications in probabilistic decision support systems and in combination with other sources of information.

  3. Differences in the associations of anthropometric measures with insulin resistance and type 2 diabetes mellitus between Korean and US populations: Comparisons of representative nationwide sample data.

    Science.gov (United States)

    Yoon, Yeong Sook; Choi, Han Seok; Kim, Jin Kuk; Kim, Yu Il; Oh, Sang Woo

    Variation among ethnic groups in the association between obesity and insulin resistance (IR)/diabetes has been suggested, but studies reported inconsistent results. We evaluated ethnic differences in the association between obesity and insulin resistance (IR)/diabetes. We conducted a cross-sectional analysis using Korea (n=18,845) and the USA (n=4657) National Health and Nutrition Examination Survey(NHANES) 2007-2010. We performed statistical comparisons of AUC-ROC (area under the curve in a receiver operating characteristic curve) values for body mass index (BMI), waist circumference (WC) and homeostasis model assessment of insulin resistance (HOMA-IR) to predict IR or diabetes among different ethnic groups. AUC-ROC values for BMI and WC for predicting IR were highest in Whites (0.8324 and 0.8468) and lowest in Koreans (0.7422 and 0.7367). Whites showed the highest AUC-ROC values for BMI (0.6869) and WC (0.7421) for predicting diabetes, while the AUC-ROC for HOMA-IR was highest in Koreans (0.8861). Linear regression showed significant interactions between ethnicity and the main effects (all Pdiabetes was highest in Whites, while the ability of HOMA-IR to predict diabetes was highest in Koreans. Copyright © 2015 Asia Oceania Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.

  4. Evaluation of Postprandial Glucose Excursion Using a Novel Minimally Invasive Glucose Area-Under-the-Curve Monitoring System

    OpenAIRE

    Kuranuki, Sachi; Sato, Toshiyuki; Okada, Seiki; Hosoya, Samiko; Seko, Akinobu; Sugihara, Kaya; Nakamura, Teiji

    2013-01-01

    Objective: To develop a minimally invasive interstitial fluid extraction technology (MIET) to monitor postprandial glucose area under the curve (AUC) without blood sampling, we evaluated the accuracy of glucose AUC measured by MIET and compared with that by blood sampling after food intake. Methods: Interstitial fluid glucose AUC (IG-AUC) following consumption of 6 different types of foods was measured by MIET. MIET consisted of stamping microneedle arrays, placing hydrogel patches on the are...

  5. Exchange Interactions on the Highest-Spin Reported Molecule: the Mixed-Valence Fe42 Complex

    Science.gov (United States)

    Aravena, Daniel; Venegas-Yazigi, Diego; Ruiz, Eliseo

    2016-04-01

    The finding of high-spin molecules that could behave as conventional magnets has been one of the main challenges in Molecular Magnetism. Here, the exchange interactions, present in the highest-spin molecule published in the literature, Fe42, have been analysed using theoretical methods based on Density Functional Theory. The system with a total spin value S = 45 is formed by 42 iron centres containing 18 high-spin FeIII ferromagnetically coupled and 24 diamagnetic low-spin FeII ions. The bridging ligands between the two paramagnetic centres are two cyanide ligands coordinated to the diamagnetic FeII cations. Calculations were performed using either small Fe4 or Fe3 models or the whole Fe42 complex, showing the presence of two different ferromagnetic couplings between the paramagnetic FeIII centres. Finally, Quantum Monte Carlo simulations for the whole system were carried out in order to compare the experimental and simulated magnetic susceptibility curves from the calculated exchange coupling constants with the experimental one. This comparison allows for the evaluation of the accuracy of different exchange-correlation functionals to reproduce such magnetic properties.

  6. Evaluation of postprandial glucose excursion using a novel minimally invasive glucose area-under-the-curve monitoring system.

    Science.gov (United States)

    Kuranuki, Sachi; Sato, Toshiyuki; Okada, Seiki; Hosoya, Samiko; Seko, Akinobu; Sugihara, Kaya; Nakamura, Teiji

    2013-01-01

    To develop a minimally invasive interstitial fluid extraction technology (MIET) to monitor postprandial glucose area under the curve (AUC) without blood sampling, we evaluated the accuracy of glucose AUC measured by MIET and compared with that by blood sampling after food intake. Interstitial fluid glucose AUC (IG-AUC) following consumption of 6 different types of foods was measured by MIET. MIET consisted of stamping microneedle arrays, placing hydrogel patches on the areas, and calculating IG-AUC based on glucose levels in the hydrogels. Glycemic index (GI) was determined using IG-AUC and reference AUC measured by blood sampling. IG-AUC strongly correlated with reference AUC (R = 0.91), and GI determined using IG-AUC showed good correlation with that determined by reference AUC (R = 0.88). IG-AUC obtained by MIET can accurately predict the postprandial glucose excursion without blood sampling. In addition, feasibility of GI measurement by MIET was confirmed.

  7. Effects of accuracy motivation and anchoring on metacomprehension judgment and accuracy.

    Science.gov (United States)

    Zhao, Qin

    2012-01-01

    The current research investigates how accuracy motivation impacts anchoring and adjustment in metacomprehension judgment and how accuracy motivation and anchoring affect metacomprehension accuracy. Participants were randomly assigned to one of six conditions produced by the between-subjects factorial design involving accuracy motivation (incentive or no) and peer performance anchor (95%, 55%, or no). Two studies showed that accuracy motivation did not impact anchoring bias, but the adjustment-from-anchor process occurred. Accuracy incentive increased anchor-judgment gap for the 95% anchor but not for the 55% anchor, which induced less certainty about the direction of adjustment. The findings offer support to the integrative theory of anchoring. Additionally, the two studies revealed a "power struggle" between accuracy motivation and anchoring in influencing metacomprehension accuracy. Accuracy motivation could improve metacomprehension accuracy in spite of anchoring effect, but if anchoring effect is too strong, it could overpower the motivation effect. The implications of the findings were discussed.

  8. Diagnostic accuracy of contrast enhanced ultrasound in patients with blunt abdominal trauma presenting to the emergency department: a systematic review and meta-analysis.

    Science.gov (United States)

    Zhang, Zhongheng; Hong, Yucai; Liu, Ning; Chen, Yuhao

    2017-06-30

    We aimed to investigate the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) in evaluating blunt abdominal trauma for patients presenting to the emergency department. Electronic search of Scopus and Pubmed was performed from inception to September 2016. Human studies investigating the diagnostic accuracy of CEUS in identifying abdominal solid organ injuries were included. Risk of bias was assessed using the QUADAS tool. A total of 10 studies were included in the study and 9 of them were included for meta-analysis. The log(DOR) values ranged from 3.80 (95% CI: 2.81-4.79) to 8.52 (95% CI: 4.58-12.47) in component studies. The combined log(DOR) was 6.56 (95% CI: 5.66-7.45). The Cochran's Q was 11.265 (p = 0.793 with 16 degrees of freedom), and the Higgins' I 2 was 0%. The CEUS had a sensitivity of 0.981 (95% CI: 0.868-0.950) and a false positive rate of 0.018 (95% CI: 0.010-0.032) for identifying parenchymal injuries, with an AUC of 0.984. CEUS performed at emergency department had good diagnostic accuracy in identifying abdominal solid organ injuries. CEUS can be recommended in monitoring solid organ injuries, especially for patients managed with non-operative strategy.

  9. Genomic Prediction Accuracy for Resistance Against Piscirickettsia salmonis in Farmed Rainbow Trout

    Directory of Open Access Journals (Sweden)

    Grazyella M. Yoshida

    2018-02-01

    Full Text Available Salmonid rickettsial syndrome (SRS, caused by the intracellular bacterium Piscirickettsia salmonis, is one of the main diseases affecting rainbow trout (Oncorhynchus mykiss farming. To accelerate genetic progress, genomic selection methods can be used as an effective approach to control the disease. The aims of this study were: (i to compare the accuracy of estimated breeding values using pedigree-based best linear unbiased prediction (PBLUP with genomic BLUP (GBLUP, single-step GBLUP (ssGBLUP, Bayes C, and Bayesian Lasso (LASSO; and (ii to test the accuracy of genomic prediction and PBLUP using different marker densities (0.5, 3, 10, 20, and 27 K for resistance against P. salmonis in rainbow trout. Phenotypes were recorded as number of days to death (DD and binary survival (BS from 2416 fish challenged with P. salmonis. A total of 1934 fish were genotyped using a 57 K single-nucleotide polymorphism (SNP array. All genomic prediction methods achieved higher accuracies than PBLUP. The relative increase in accuracy for different genomic models ranged from 28 to 41% for both DD and BS at 27 K SNP. Between different genomic models, the highest relative increase in accuracy was obtained with Bayes C (∼40%, where 3 K SNP was enough to achieve a similar accuracy to that of the 27 K SNP for both traits. For resistance against P. salmonis in rainbow trout, we showed that genomic predictions using GBLUP, ssGBLUP, Bayes C, and LASSO can increase accuracy compared with PBLUP. Moreover, it is possible to use relatively low-density SNP panels for genomic prediction without compromising accuracy predictions for resistance against P. salmonis in rainbow trout.

  10. Diagnostic Accuracy of MRI Versus CT for the Evaluation of Acute Appendicitis in Children and Young Adults.

    Science.gov (United States)

    Kinner, Sonja; Pickhardt, Perry J; Riedesel, Erica L; Gill, Kara G; Robbins, Jessica B; Kitchin, Douglas R; Ziemlewicz, Timothy J; Harringa, John B; Reeder, Scott B; Repplinger, Michael D

    2017-10-01

    Appendicitis is frequently diagnosed in the emergency department, most commonly using CT. The purpose of this study was to compare the diagnostic accuracy of contrast-enhanced MRI with that of contrast-enhanced CT for the diagnosis of appendicitis in adolescents when interpreted by abdominal radiologists and pediatric radiologists. Our study included a prospectively enrolled cohort of 48 patients (12-20 years old) with nontraumatic abdominal pain who underwent CT and MRI. Fellowship-trained abdominal and pediatric radiologists reviewed all CT and MRI studies in randomized order, blinded to patient outcome. Likelihood for appendicitis was rated on a 5-point scale (1, definitely not appendicitis; 5, definitely appendicitis) for CT, the unenhanced portion of the MRI, and the entire contrast-enhanced MRI study. ROC curves were generated and AUC compared for each scan type for all six readers and then stratified by radiologist type. Image test characteristics, interrater reliability, and reading times were compared. Sensitivity and specificity were 85.9% (95% CI, 76.2-92.7%) and 93.8% (95% CI, 89.7-96.7%) for unenhanced MRI, 93.6% (95% CI, 85.6-97.9%) and 94.3% (95% CI, 90.2-97%) for contrast-enhanced MRI, and 93.6% (95% CI, 85.6-97.9%) and 94.3% (95% CI, 90.2-97%) for CT. No difference was found in the diagnostic accuracy or interpretation time when comparing abdominal radiologists to pediatric radiologists (CT, 3.0 min vs 2.8 min; contrast-enhanced MRI, 2.4 min vs 1.8 min; unenhanced MRI, 1.5 min vs 2.3 min). Substantial agreement between abdominal and pediatric radiologists was seen for all methods (κ = 0.72-0.83). The diagnostic accuracy of MRI to diagnose appendicitis was very similar to CT. No statistically significant difference in accuracy was observed between imaging modality or radiologist subspecialty.

  11. Diagnostic accuracy of plain radiographs and cineradiography in diagnosing traumatic scapholunate dissociation

    International Nuclear Information System (INIS)

    Pliefke, Jenny; Eisenschenk, Andreas; Stengel, Dirk; Ekkernkamp, Axel; Rademacher, Grit; Mutze, Sven

    2008-01-01

    Missed tears of the scapholunate ligament (SLL) and scapholunate dissociation (SLD) after wrist injuries pose a high risk of post-traumatic osteoarthritis of the carpus. Plain X-rays and dynamic radiographic studies are frequently used for initial diagnostic work-up. Given the limited evidence of their accuracy, we retrospectively compared the radiographic findings of patients with suspected traumatic SLD with wrist arthroscopy as the accepted reference standard. During a 6-year period, plain radiographs and DSA cineradiography scans were obtained from 198 patients who had sustained a hyperextension injury to their hand. Of those, 102 (72 men, 30 women, mean age of 42 ± 12 years) subsequently underwent diagnostic arthroscopy. Digital images were reevaluated by experienced radiologists unaware of the arthroscopic findings for the presence or absence of SLD. We calculated the sensitivity (SN) and specificity (SP) with 95% confidence intervals (CI), and computed areas under the receiver operating characteristic curves (AUC/ROC). Arthroscopy revealed 42 SLL ruptures, 13, 10, and 19 of which were classified as grade I (partial), II (complete with dynamic instability), or III (complete with static instability) respectively. Plain radiographs correctly identified 24 injuries (SN 57.1%, 95% CI 41.0-72.3%), and produced 1 false-positive result (SP 98.3%, 95% CI 91.1-100.0%). The scapholunate distance and the SL angle contributed independently to the diagnostic variance, with an AUC/ROC of 85.7% (95% CI 76.8-92.2%). Cineradiography had a sensitivity of 36 out of 42 (85.7%, 95% CI 71.5-94.6%), and a specificity of 57 out of 60 (95.0%, 95% CI 86.1-99.0%). Pathological results on plain radiographs and cineradiography reliably indicate the presence of SLD after wrist trauma. Although non-conclusive, a negative dynamic study markedly reduces the pre-test probability of disease. Both methods remain key elements of primary diagnostic strategies for suspected traumatic SLD, and may

  12. Pulmonary Artery Catheter (PAC Accuracy and Efficacy Compared with Flow Probe and Transcutaneous Doppler (USCOM: An Ovine Cardiac Output Validation

    Directory of Open Access Journals (Sweden)

    Robert A. Phillips

    2012-01-01

    Full Text Available Background. The pulmonary artery catheter (PAC is an accepted clinical method of measuring cardiac output (CO despite no prior validation. The ultrasonic cardiac output monitor (USCOM is a noninvasive alternative to PAC using Doppler ultrasound (CW. We compared PAC and USCOM CO measurements against a gold standard, the aortic flow probe (FP, in sheep at varying outputs. Methods. Ten conscious sheep, with implanted FPs, had measurements of CO by FP, USCOM, and PAC, at rest and during intervention with inotropes and vasopressors. Results. CO measurements by FP, PAC, and USCOM were 4.0±1.2 L/min, 4.8±1.5 L/min, and 4.0±1.4 L/min, respectively, (=280, range 1.9 L/min to 11.7 L/min. Percentage bias and precision between FP and PAC, and FP and USCOM was −17 and 47%, and 1 and 36%, respectively. PAC under-measured Dobutamine-induced CO changes by 20% (relative 66% compared with FP, while USCOM measures varied from FP by 3% (relative 10%. PAC reliably detected −30% but not +40% CO changes, as measured by receiver operating characteristic area under the curve (AUC, while USCOM reliably detected ±5% changes in CO (AUC>0.70. Conclusions. PAC demonstrated poor accuracy and sensitivity as a measure of CO. USCOM provided equivalent measurements to FP across a sixfold range of outputs, reliably detecting ±5% changes.

  13. Increased prognostic accuracy of TBI when a brain electrical activity biomarker is added to loss of consciousness (LOC).

    Science.gov (United States)

    Hack, Dallas; Huff, J Stephen; Curley, Kenneth; Naunheim, Roseanne; Ghosh Dastidar, Samanwoy; Prichep, Leslie S

    2017-07-01

    Extremely high accuracy for predicting CT+ traumatic brain injury (TBI) using a quantitative EEG (QEEG) based multivariate classification algorithm was demonstrated in an independent validation trial, in Emergency Department (ED) patients, using an easy to use handheld device. This study compares the predictive power using that algorithm (which includes LOC and amnesia), to the predictive power of LOC alone or LOC plus traumatic amnesia. ED patients 18-85years presenting within 72h of closed head injury, with GSC 12-15, were study candidates. 680 patients with known absence or presence of LOC were enrolled (145 CT+ and 535 CT- patients). 5-10min of eyes closed EEG was acquired using the Ahead 300 handheld device, from frontal and frontotemporal regions. The same classification algorithm methodology was used for both the EEG based and the LOC based algorithms. Predictive power was evaluated using area under the ROC curve (AUC) and odds ratios. The QEEG based classification algorithm demonstrated significant improvement in predictive power compared with LOC alone, both in improved AUC (83% improvement) and odds ratio (increase from 4.65 to 16.22). Adding RGA and/or PTA to LOC was not improved over LOC alone. Rapid triage of TBI relies on strong initial predictors. Addition of an electrophysiological based marker was shown to outperform report of LOC alone or LOC plus amnesia, in determining risk of an intracranial bleed. In addition, ease of use at point-of-care, non-invasive, and rapid result using such technology suggests significant value added to standard clinical prediction. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Support vector machine-based classification of neuroimages in Alzheimer’s disease: direct comparison of FDG-PET, rCBF-SPECT and MRI data acquired from the same individuals

    Directory of Open Access Journals (Sweden)

    Luiz K. Ferreira

    2017-10-01

    Full Text Available Objective: To conduct the first support vector machine (SVM-based study comparing the diagnostic accuracy of T1-weighted magnetic resonance imaging (T1-MRI, F-fluorodeoxyglucose-positron emission tomography (FDG-PET and regional cerebral blood flow single-photon emission computed tomography (rCBF-SPECT in Alzheimer’s disease (AD. Method: Brain T1-MRI, FDG-PET and rCBF-SPECT scans were acquired from a sample of mild AD patients (n=20 and healthy elderly controls (n=18. SVM-based diagnostic accuracy indices were calculated using whole-brain information and leave-one-out cross-validation. Results: The accuracy obtained using PET and SPECT data were similar. PET accuracy was 68∼71% and area under curve (AUC 0.77∼0.81; SPECT accuracy was 68∼74% and AUC 0.75∼0.79, and both had better performance than analysis with T1-MRI data (accuracy of 58%, AUC 0.67. The addition of PET or SPECT to MRI produced higher accuracy indices (68∼74%; AUC: 0.74∼0.82 than T1-MRI alone, but these were not clearly superior to the isolated neurofunctional modalities. Conclusion: In line with previous evidence, FDG-PET and rCBF-SPECT more accurately identified patients with AD than T1-MRI, and the addition of either PET or SPECT to T1-MRI data yielded increased accuracy. The comparable SPECT and PET performances, directly demonstrated for the first time in the present study, support the view that rCBF-SPECT still has a role to play in AD diagnosis.

  15. Evaluation of Postprandial Glucose Excursion Using a Novel Minimally Invasive Glucose Area-Under-the-Curve Monitoring System

    Directory of Open Access Journals (Sweden)

    Sachi Kuranuki

    2013-01-01

    Full Text Available Objective: To develop a minimally invasive interstitial fluid extraction technology (MIET to monitor postprandial glucose area under the curve (AUC without blood sampling, we evaluated the accuracy of glucose AUC measured by MIET and compared with that by blood sampling after food intake. Methods: Interstitial fluid glucose AUC (IG-AUC following consumption of 6 different types of foods was measured by MIET. MIET consisted of stamping microneedle arrays, placing hydrogel patches on the areas, and calculating IG-AUC based on glucose levels in the hydrogels. Glycemic index (GI was determined using IG-AUC and reference AUC measured by blood sampling. Results: IG-AUC strongly correlated with reference AUC (R = 0.91, and GI determined using IG-AUC showed good correlation with that determined by reference AUC (R = 0.88. Conclusions: IG-AUC obtained by MIET can accurately predict the postprandial glucose excursion without blood sampling. In addition, feasibility of GI measurement by MIET was confirmed.

  16. The role of multi-parametric MR imaging in the detection of early inflammatory sacroiliitis according to ASAS criteria

    Energy Technology Data Exchange (ETDEWEB)

    Boy, Fatma Nur, E-mail: nursoylu@yahoo.com [Department of Radiology, Fatih Sultan Mehmet Training and Research Hospital, E-5 Karayolu Uzeri, 34752 Atasehir, Istanbul (Turkey); Kayhan, Arda, E-mail: arda_kayhan@yahoo.com [Health Services Vocational School, Esenyurt University, Dogan Arasli Bulvari No 120, Esenyurt, Istanbul (Turkey); Karakas, Hakki Muammer, E-mail: hakki.karakas@gmail.com [Department of Radiology, Fatih Sultan Mehmet Training and Research Hospital, E-5 Karayolu Uzeri, 34752 Atasehir, Istanbul (Turkey); Unlu-Ozkan, Feyza, E-mail: feyzamd@yahoo.com [Department of Physical Therapy and Rehabilitation, Fatih Sultan Mehmet Training and Research Hospital, E-5 Karayolu Uzeri, 34752 Atasehir, Istanbul (Turkey); Silte, Duygu, E-mail: drduygusilte@hotmail.com [Department of Physical Therapy and Rehabilitation, Fatih Sultan Mehmet Training and Research Hospital, E-5 Karayolu Uzeri, 34752 Atasehir, Istanbul (Turkey); Aktas, İlknur, E-mail: iaktas@hotmail.com [Department of Physical Therapy and Rehabilitation, Fatih Sultan Mehmet Training and Research Hospital, E-5 Karayolu Uzeri, 34752 Atasehir, Istanbul (Turkey)

    2014-06-15

    Purpose: To retrospectively evaluate the accuracy of multi-parametric magnetic resonance (MR) imaging including fat saturated (FS) T2-weighted, short-tau inversion recovery (STIR), diffusion-weighted (DW-MR), and dynamic-contrast-enhanced MR (DCE-MR) imaging techniques in the diagnosis of early inflammatory sacroiliitis and determine the additional value of DW-MR and DCE-MR images according to recently defined ‘Assessment in SpondyloArthritis international Society’ criteria. Materials and methods: The study included 45 patients with back pain. Two radiologists estimated the likelihood of osteitis in 4 independent viewing sessions including FS T2-weighted, STIR, DW-MR and DCE-MR images. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the receiver operating characteristic (ROC) curve (AUC) were calculated. Results: Of the 45 patients, 31 had inflammatory back pain. Of 31, 28 (90.3%) patients had inflammatory sacroiliitis diagnosed by clinical and laboratory analysis. FS T2-weighted MR images had the highest sensitivity (42.8% for both radiologists) for detecting osteitis in patients with inflammaory sacroiliitis when compared to other imaging sequences. For specificity, PPV, NPV, accuracy, and AUC levels there were no statistically significant difference between image viewing settings. However, adding STIR, DW-MR and DCE-MR images to the FS T2-weighted MR images did not improve the above stated indices. Conclusion: FS T2-weighted MR imaging had the highest sensitivity when compared to other imaging sequences. The addition of DW-MR and DCE-MR images did not significantly improve the diagnostic value of MR imaging in the diagnosis of osteitis for both experienced and less experienced radiologists.

  17. The role of multi-parametric MR imaging in the detection of early inflammatory sacroiliitis according to ASAS criteria

    International Nuclear Information System (INIS)

    Boy, Fatma Nur; Kayhan, Arda; Karakas, Hakki Muammer; Unlu-Ozkan, Feyza; Silte, Duygu; Aktas, İlknur

    2014-01-01

    Purpose: To retrospectively evaluate the accuracy of multi-parametric magnetic resonance (MR) imaging including fat saturated (FS) T2-weighted, short-tau inversion recovery (STIR), diffusion-weighted (DW-MR), and dynamic-contrast-enhanced MR (DCE-MR) imaging techniques in the diagnosis of early inflammatory sacroiliitis and determine the additional value of DW-MR and DCE-MR images according to recently defined ‘Assessment in SpondyloArthritis international Society’ criteria. Materials and methods: The study included 45 patients with back pain. Two radiologists estimated the likelihood of osteitis in 4 independent viewing sessions including FS T2-weighted, STIR, DW-MR and DCE-MR images. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the receiver operating characteristic (ROC) curve (AUC) were calculated. Results: Of the 45 patients, 31 had inflammatory back pain. Of 31, 28 (90.3%) patients had inflammatory sacroiliitis diagnosed by clinical and laboratory analysis. FS T2-weighted MR images had the highest sensitivity (42.8% for both radiologists) for detecting osteitis in patients with inflammaory sacroiliitis when compared to other imaging sequences. For specificity, PPV, NPV, accuracy, and AUC levels there were no statistically significant difference between image viewing settings. However, adding STIR, DW-MR and DCE-MR images to the FS T2-weighted MR images did not improve the above stated indices. Conclusion: FS T2-weighted MR imaging had the highest sensitivity when compared to other imaging sequences. The addition of DW-MR and DCE-MR images did not significantly improve the diagnostic value of MR imaging in the diagnosis of osteitis for both experienced and less experienced radiologists

  18. Commissioning Procedures for Mechanical Precision and Accuracy in a Dedicated LINAC

    International Nuclear Information System (INIS)

    Ballesteros-Zebadua, P.; Larrga-Gutierrez, J. M.; Garcia-Garduno, O. A.; Juarez, J.; Prieto, I.; Moreno-Jimenez, S.; Celis, M. A.

    2008-01-01

    Mechanical precision measurements are fundamental procedures for the commissioning of a dedicated LINAC. At our Radioneurosurgery Unit, these procedures can be suitable as quality assurance routines that allow the verification of the equipment geometrical accuracy and precision. In this work mechanical tests were performed for gantry and table rotation, obtaining mean associated uncertainties of 0.3 mm and 0.71 mm, respectively. Using an anthropomorphic phantom and a series of localized surface markers, isocenter accuracy showed to be smaller than 0.86 mm for radiosurgery procedures and 0.95 mm for fractionated treatments with mask. All uncertainties were below tolerances. The highest contribution to mechanical variations is due to table rotation, so it is important to correct variations using a localization frame with printed overlays. Mechanical precision knowledge would allow to consider the statistical errors in the treatment planning volume margins

  19. An exposure-response analysis based on rifampin suggests CYP3A4 induction is driven by AUC: an in vitro investigation.

    Science.gov (United States)

    Chang, Cheng; Yang, Xin; Fahmi, Odette A; Riccardi, Keith A; Di, Li; Obach, R Scott

    2017-08-01

    1. Induction is an important mechanism contributing to drug-drug interactions. It is most commonly evaluated in the human hepatocyte assay over 48-h or 72-h incubation period. However, whether the overall exposure (i.e. Area Under the Curve (AUC) or C ave ) or maximum exposure (i.e. C max ) of the inducer is responsible for the magnitude of subsequent induction has not been thoroughly investigated. Additionally, in vitro induction assays are typically treated as static systems, which could lead to inaccurate induction potency estimation. Hence, European Medicines Agency (EMA) guidance now specifies quantitation of drug levels in the incubation. 2. This work treated the typical in vitro evaluation of rifampin induction as an in vivo system by generating various target engagement profiles, measuring free rifampin concentration over 3 d of incubation and evaluating the impact of these factors on final induction response. 3. This rifampin-based analysis demonstrates that the induction process is driven by time-averaged target engagement (i.e. AUC-driven). Additionally, depletion of rifampin in the incubation medium over 3 d as well as non-specific/specific binding were observed. 4. These findings should help aid the discovery of clinical candidates with minimal induction liability and further expand our knowledge in the quantitative translatability of in vitro induction assays.

  20. Dynamical coupling of PBPK/PD and AUC-based toxicity models for arsenic in tilapia Oreochromis mossambicus from blackfoot disease area in Taiwan

    International Nuclear Information System (INIS)

    Liao, C.-M.; Liang, H.-M.; Chen, B.-C.; Singh Sher; Tsai, J.-W.; Chou, Y.-H.; Lin, W.-T.

    2005-01-01

    A physiologically based pharmacokinetic and pharmacodynamic (PBPK/PD) models were developed for arsenic (As) in tilapia Oreochromis mossambicus from blackfoot disease area in Taiwan. The PBPK/PD model structure consisted of muscle, gill, gut wall, alimentary canal, and liver, which were interconnected by blood circulation. We integrate the target organ concentrations and dynamic response describing uptake, metabolism, and disposition of As and the associated area-under-curve (AUC)-based toxicological dynamics following an acute exposure. The model validations were compared against the field observations from real tilapia farms and previously published uptake/depuration experimental data, indicating that predicted and measured As concentrations in major organs of tilapia were in good agreement. The model was utilized to reasonably simulate and construct a dose-dependent dynamic response between mortality effect and equilibrium target organ concentrations. Model simulations suggest that tilapia gills may serve as a surrogate sensitive biomarker of short-term exposure to As. This integrated As PBPK/PD/AUC model quantitatively estimates target organ concentration and dynamic response in tilapia and is a strong framework for future waterborne metal model development and for refining a biologically-based risk assessment for exposure of aquatic species to waterborne metals under a variety of scenarios. - Integrated toxicity models can identify dynamic responses of fish to arsenic

  1. Dynamical coupling of PBPK/PD and AUC-based toxicity models for arsenic in tilapia Oreochromis mossambicus from blackfoot disease area in Taiwan

    Energy Technology Data Exchange (ETDEWEB)

    Liao, C.-M. [Ecotoxicological Modeling Center, Department of Bioenvironmental Systems Engineering, National Taiwan University, Taipei, Taiwan 10617 (China)]. E-mail: cmliao@ntu.edu.tw; Liang, H.-M. [Ecotoxicological Modeling Center, Department of Bioenvironmental Systems Engineering, National Taiwan University, Taipei, Taiwan 10617 (China); Chen, B.-C. [Department of Post-Modern Agriculture, Mingdao University, Changhua, Taiwan 52345 (China); Singh Sher [Center of Genomics Medicine, School of Medicine, National Taiwan University, Taipei, Taiwan 10617 (China); Tsai, J.-W. [Ecotoxicological Modeling Center, Department of Bioenvironmental Systems Engineering, National Taiwan University, Taipei, Taiwan 10617 (China); Chou, Y.-H. [Ecotoxicological Modeling Center, Department of Bioenvironmental Systems Engineering, National Taiwan University, Taipei, Taiwan 10617 (China); Lin, W.-T. [Environment Change Research Center, Academia Sinica, Nankang, Taipei, Taiwan 11517 (China)

    2005-05-01

    A physiologically based pharmacokinetic and pharmacodynamic (PBPK/PD) models were developed for arsenic (As) in tilapia Oreochromis mossambicus from blackfoot disease area in Taiwan. The PBPK/PD model structure consisted of muscle, gill, gut wall, alimentary canal, and liver, which were interconnected by blood circulation. We integrate the target organ concentrations and dynamic response describing uptake, metabolism, and disposition of As and the associated area-under-curve (AUC)-based toxicological dynamics following an acute exposure. The model validations were compared against the field observations from real tilapia farms and previously published uptake/depuration experimental data, indicating that predicted and measured As concentrations in major organs of tilapia were in good agreement. The model was utilized to reasonably simulate and construct a dose-dependent dynamic response between mortality effect and equilibrium target organ concentrations. Model simulations suggest that tilapia gills may serve as a surrogate sensitive biomarker of short-term exposure to As. This integrated As PBPK/PD/AUC model quantitatively estimates target organ concentration and dynamic response in tilapia and is a strong framework for future waterborne metal model development and for refining a biologically-based risk assessment for exposure of aquatic species to waterborne metals under a variety of scenarios. - Integrated toxicity models can identify dynamic responses of fish to arsenic.

  2. Accuracy of the Defining Characteristics of the Nursing Diagnosis Hypothermia in Newborns.

    Science.gov (United States)

    de Aquino, Wislla Ketlly Menezes; Lopes, Marcos Venícios de Oliveira; da Silva, Viviane Martins; Fróes, Nathaly Bianka Moraes; de Menezes, Angélica Paixão; Almeida, Aline de Aquino Peres; Sobreira, Bianca Alves

    2017-09-18

    To analyze the accuracy of the defining characteristics of hypothermia in newborns and to verify associations between defining characteristics and clinical variables. A cross-sectional accuracy study with statistical analysis. Slow capillary refill, decrease in ventilation, peripheral vasoconstriction, and insufficient weight gain were the defining characteristics with the highest specificity values, while slow gastric emptying, skin cool to touch, irritability, and bradycardia were the defining characteristics with the highest values for both sensitivity and specificity. Slow gastric emptying, skin cool to touch, irritability, and bradycardia are good clinical indicators to infer initial stages of hypothermia and to confirm its presence. Accuracy measures may contribute to the improvement of the diagnostic inferential process. Analisar acurácia das características definidoras de Hipotermia em recém-nascidos e identificar a associação delas com variáveis clínicas. MÉTODO: Estudo de acurácia transversal com análise estatística. Preenchimento capilar lento, diminuição da ventilação, vasoconstrição periférica e ganho de peso insuficiente apresentaram valores altos de especificidade enquanto esvaziamento gástrico lento, pele fria, irritabilidade e bradicardia apresentaram valores elevados de sensibilidade e especificidade. CONCLUSÃO: Esvaziamento gástrico lento, pele fria, irritabilidade e bradicardia são úteis para inferir estágios iniciais de hipotermia e para confirmação diagnóstica. IMPLICAÇÕES PARA PRÁTICA DE ENFERMAGEM: Medidas de acurácia podem contribuir para o processo de inferência do diagnóstico hipotermia. © 2017 NANDA International, Inc.

  3. Increasing the predictive accuracy of amyloid-β blood-borne biomarkers in Alzheimer's disease.

    Science.gov (United States)

    Watt, Andrew D; Perez, Keyla A; Faux, Noel G; Pike, Kerryn E; Rowe, Christopher C; Bourgeat, Pierrick; Salvado, Olivier; Masters, Colin L; Villemagne, Victor L; Barnham, Kevin J

    2011-01-01

    Diagnostic measures for Alzheimer's disease (AD) commonly rely on evaluating the levels of amyloid-β (Aβ) peptides within the cerebrospinal fluid (CSF) of affected individuals. These levels are often combined with levels of an additional non-Aβ marker to increase predictive accuracy. Recent efforts to overcome the invasive nature of CSF collection led to the observation of Aβ species within the blood cellular fraction, however, little is known of what additional biomarkers may be found in this membranous fraction. The current study aimed to undertake a discovery-based proteomic investigation of the blood cellular fraction from AD patients (n = 18) and healthy controls (HC; n = 15) using copper immobilized metal affinity capture and Surface Enhanced Laser Desorption/Ionisation Time-Of-Flight Mass Spectrometry. Three candidate biomarkers were observed which could differentiate AD patients from HC (ROC AUC > 0.8). Bivariate pairwise comparisons revealed significant correlations between these markers and measures of AD severity including; MMSE, composite memory, brain amyloid burden, and hippocampal volume. A partial least squares regression model was generated using the three candidate markers along with blood levels of Aβ. This model was able to distinguish AD from HC with high specificity (90%) and sensitivity (77%) and was able to separate individuals with mild cognitive impairment (MCI) who converted to AD from MCI non-converters. While requiring further characterization, these candidate biomarkers reaffirm the potential efficacy of blood-based investigations into neurodegenerative conditions. Furthermore, the findings indicate that the incorporation of non-amyloid markers into predictive models, function to increase the accuracy of the diagnostic potential of Aβ.

  4. Innovative Route to Prepare of Au/C Catalysts by Replication of Gold-containing Mesoporous Silicas

    KAUST Repository

    Kerdi, Fatmé

    2011-12-23

    Gold-catalyzed aerobic epoxidations in the liquid phase are generally performed in low-polarity solvents, in which conventional oxide-supported catalysts are poorly dispersed. To improve the wettability of the catalytic powder and, thus, the efficiency of the catalyst, gold nanoparticles (NPs) have been dispersed on meso-structured carbons. Gold is first introduced in functionalized mesostructured silica and particles are formed inside the porosity. Silica pores are then impregnated with a carbon precursor and the composite material is heated at 900 °C under vacuum or nitrogen. Silica is then removed by acid leaching, leading to partially encapsulated gold particles in mesoporous carbon. Carbon prevents aggregation of gold particles at high temperature, both the mean size and distribution being similar to those observed in silica. However, while Au@SiO2 exhibit significant catalytic activity in the aerobic oxidation of trans-stilbene in the liquid phase, its Au@C mesostructured replica is quite inactive.

  5. Target Price Accuracy

    Directory of Open Access Journals (Sweden)

    Alexander G. Kerl

    2011-04-01

    Full Text Available This study analyzes the accuracy of forecasted target prices within analysts’ reports. We compute a measure for target price forecast accuracy that evaluates the ability of analysts to exactly forecast the ex-ante (unknown 12-month stock price. Furthermore, we determine factors that explain this accuracy. Target price accuracy is negatively related to analyst-specific optimism and stock-specific risk (measured by volatility and price-to-book ratio. However, target price accuracy is positively related to the level of detail of each report, company size and the reputation of the investment bank. The potential conflicts of interests between an analyst and a covered company do not bias forecast accuracy.

  6. Estimation of plasma area under the curve for etanidazole (SR 2508) in toxicity prediction and dose adjustment

    International Nuclear Information System (INIS)

    Workman, P.; Ward, R.; Maughan, T.S.; Newman, H.F.; Bleehen, N.M.

    1989-01-01

    The hydrophilic 2-nitroimidazole radiosensitizer etanidazole is currently undergoing clinical evaluation. Although considerably less neurotoxic than misonidazole because of its rapid renal clearance and partial exclusion from the nervous system, total dose is limited by peripheral neuropathy. Monitoring plasma etanidazole concentration in patients to determine the area under the curve (AUC0-infinity) has been proposed as a method of predicting patients at risk, and of providing a quantitative basis for dose reduction in such patients. Successful application of this policy requires accurate assessment of AUC0-infinity. We have analyzed plasma data for 18 patients receiving 2 g/m2 etanidazole to determine the errors introduced in the estimation of AUC0-infinity caused by omitting selected time points from the analysis. A 'baseline' AUC0-infinity value was calculated by integration of the rate equation for the 2-compartment model using data points at 0, 15, and 30 min and 1, 2, 4, 8, 12, and 24 hr after the end of infusion. The mean +/- SD area for AUC0-infinity was 502 +/- 152 micrograms ml-1 h (2.35 +/- 0.71 mM.h). Omitting the zero or the 24 hr time point, the average errors were quite small (2.5% in both cases), but errors of up to 16.4 and 7.3%, respectively, were seen for individual patients. Leaving out both the 8 hr and 12 hr points at the same time gave a similar low average error of 2.9%, with a highest error of 7.3%. Omitting all data points after 4 hr, the mean error was 24.7% and 15 of 18 patients had errors in excess of 10%. In addition, failure to correct for infusion time results in an underestimation of AUC0-infinity averaging 4.5% (range 1.9-8.7%). The choice of sampling times for toxicological monitoring will depend upon the accuracy with which the AUC0-infinity must be known. Including all data points between 0 and 24 hr will minimize errors

  7. Combined 3 Tesla MRI Biomarkers Improve the Differentiation between Benign vs Malignant Single Ring Enhancing Brain Masses.

    Directory of Open Access Journals (Sweden)

    Simone Salice

    Full Text Available To evaluate whether the combination of imaging biomarkers obtained by means of different 3 Tesla (3T Magnetic Resonance Imaging (MRI advanced techniques can improve the diagnostic accuracy in the differentiation between benign and malignant single ring-enhancing brain masses.14 patients presenting at conventional 3T MRI single brain mass with similar appearance as regard ring enhancement, presence of peri-lesional edema and absence of hemorrhage signs were included in the study. All lesions were histologically proven: 5 pyogenic abscesses, 6 glioblastomas, and 3 metastases. MRI was performed at 3 Tesla and included Diffusion Weighted Imaging (DWI, Dynamic Susceptibility Contrast -Perfusion Weighted Imaging (DSC-PWI, Magnetic Resonance Spectroscopy (MRS, and Diffusion Tensor Imaging (DTI. Imaging biomarkers derived by those advanced techniques [Cerebral Blood Flow (CBF, relative Cerebral Blood Volume (rCBV, relative Main Transit Time (rMTT, Choline (Cho, Creatine (Cr, Succinate, N-Acetyl Aspartate (NAA, Lactate (Lac, Lipids, relative Apparent Diffusion Coefficient (rADC, and Fractional Anisotropy (FA] were detected by two experienced neuroradiologists in joint session in 4 areas: Internal Cavity (IC, Ring Enhancement (RE, Peri-Lesional edema (PL, and Contralateral Normal Appearing White Matter (CNAWM. Significant differences between benign (n = 5 and malignant (n = 9 ring enhancing lesions were tested with Mann-Withney U test. The diagnostic accuracy of MRI biomarkers taken alone and MRI biomarkers ratios were tested with Receiver Operating Characteristic (ROC analysis with an Area Under the Curve (AUC ≥ 0.9 indicating a very good diagnostic accuracy of the variable.Five MRI biomarker ratios achieved excellent accuracy: IC-rADC/PL-NAA (AUC = 1, IC-rADC/IC-FA (AUC = 0.978, RE-rCBV/RE-FA (AUC = 0.933, IC-rADC/RE-FA (AUC = 0.911, and IC-rADC/PL-FA (AUC = 0.911. Only IC-rADC achieved a very good diagnostic accuracy (AUC = 0.909 among MRI biomarkers

  8. Do optimally ripe blackberries contain the highest levels of metabolites?

    Science.gov (United States)

    Mikulic-Petkovsek, Maja; Koron, Darinka; Zorenc, Zala; Veberic, Robert

    2017-01-15

    Five blackberry cultivars were selected for the study ('Chester Thornless', 'Cacanska Bestrna', 'Loch Ness', 'Smoothstem' and 'Thornfree') and harvested at three different maturity stages (under-, optimal- and over-ripe). Optimally ripe and over-ripe blackberries contained significantly higher levels of total sugars compared to under-ripe fruit. 'Loch Ness' cultivar was characterized by 2.2-2.6-fold higher levels of total sugars than other cultivars and consequently, the highest sugar/acids ratio. 'Chester Thornless' stands out as the cultivar with the highest level of vitamin C in under-ripe (125.87mgkg(-1)) and optimally mature fruit (127.66mgkg(-1)). Maturity stage significantly affected the accumulation of phenolic compounds. The content of total anthocyanins increased for 43% at optimal maturity stage and cinnamic acid derivatives for 57% compared to under-ripe fruit. Over-ripe blackberries were distinguished by the highest content of total phenolics (1251-2115mg GAE kg(-1) FW) and greatest FRAP values (25.9-43.2mM TE kg(-1) FW). Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Ventricular short-axis measurements in patients with pulmonary embolism: Effect of ECG-gating on variability, accuracy, and risk prediction

    International Nuclear Information System (INIS)

    Scheffel, Hans; Stolzmann, Paul; Leschka, Sebastian; Desbiolles, Lotus; Seifert, Burkhardt; Marincek, Borut; Alkadhi, Hatem

    2012-01-01

    Objective: To assess prospectively the intra- and interobserver variability, accuracy, and prognostic value of right and left ventricular short-axis diameter (RVd and LVd) measurements for risk stratification in patients with pulmonary embolism (PE) using ECG-gated compared to non-gated CT. Materials and methods: Sixty consecutive patients (33 women; mean age 58.7 ± 10.3 years) with suspicion of PE underwent both non-gated and ECG-gated chest CT. RVd and LVd on four-chamber views and intra- and interobserver agreements were calculated for both protocols. RVd/LVd ratios were calculated and were related to 30-days adverse clinical events using receiver operating characteristics with area-under-the-curve (AUC) analyses. Results: Both inter- and intraobserver variability showed narrower limits of agreement for all measurements with ECG-gated as compared to non-gated CT. Diameter measurements were significantly lower using non-ECG-gated CT as compared to ECG-gated CT for RVd and LVd (both p < .05). The AUC for the RVd/LVd ratio from ECG-gated CT was significantly larger than that from non-gated CT (0.956, 95% CI: 0.768–0.999 versus 0.675, 95% CI: 0.439–0.860; p = .048). Conclusion: RVd and LVd measurements from ECG-gated chest CT show less intra- and interobserver variability and more accurately reflect ventricular function. In our patient cohort ECG-gated chest CT allows better prediction of short-term outcome of patients with acute PE that needs to be validated in a larger outcome study

  10. Diagnostic accuracy of CTA and MRI/MRA in the evaluation of the cortical venous reflux in the intracranial dural arteriovenous fistula DAVF

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yen-Heng [National Taiwan University, Department of Medical Imaging and Radiology, Hospital and Medical College, Taipei (China); National Taiwan University Hospital, Department of Medical Imaging, Douliu City (China); Wang, Yu-Fen; Lee, Chung-Wei; Chen, Ya-Fang [National Taiwan University, Department of Medical Imaging and Radiology, Hospital and Medical College, Taipei (China); Liu, Hon-Man [National Taiwan University, Department of Medical Imaging and Radiology, Hospital and Medical College, Taipei (China); Fu Jen Catholic University, Department of Medical Imaging and Radiology, Hospital and Medical College, New Taipei City (China); Fu Jen Catholic University Hospital, Department of Medical Imaging, New Taipei City (China); Hsieh, Hong-Jen [National Taiwan University Hospital, Department of Medical Imaging, Douliu City (China)

    2018-01-15

    Computed tomography angiography (CTA) and magnetic resonance imaging/angiography (MRI/MRA) are used for the diagnosis of intracranial dural arteriovenous fistulas (DAVFs). The purpose of this study was to compare the diagnostic accuracy of CTA and magnetic resonance imaging/angiography (MRI/MRA) for detection of cortical venous reflux (CVR) in intracranial DAVFs. The records of patients with angiography-confirmed intracranial DAVFs who also received CTA and MRI/MRA from January 2008 to July 2016 were reviewed. CTA and MRI/MRA were reviewed for signs of CVR, and the diagnostic accuracy of individual signs was evaluated by receiver operating curve (ROC) analysis. A total 108 patients were included in this study. CTA signs of CVR included abnormal dilatation, early enhancement, and the presence of a medullary or pial vein. MRI/MRA signs of CVR included abnormal dilatation, early enhancement, flow-related enhancement, flow void, and medullary or pial venous collaterals. The sensitivity of individual CTA signs ranged from 62 to 96%, and specificities from 79 to 94%. The sensitivities of individual MRI/MRA signs ranged from 58 to 83%, and specificities from 77 to 93%. The area under ROC curve (AUC) of CTA and MRI/MRA were 0.91 and 0.87, respectively (P = 0.04 in direct comparison). In subgroup analysis, CTA had better diagnostic accuracy for higher grade disease (P = 0.05) and non-aggressive manifestation (P = 0.04). Both CTA and MRI/MRA have good diagnostic accuracy for detection of CVR in patients with intracranial DAVFs. There is modest evidence that CTA is better than MRI/MRA. (orig.)

  11. Comparison of the Diagnostic Accuracy of the MSLN Gene Products, Mesothelin and Megakaryocyte Potentiating Factor, as Biomarkers for Mesothelioma in Pleural Effusions and Serum

    Directory of Open Access Journals (Sweden)

    Jenette Creaney

    2013-01-01

    Full Text Available The MSLN gene products, soluble mesothelin and megakaryocyte potentiating factor (MPF, are being investigated as biomarkers for the asbestos-related cancer malignant mesothelioma (MM. Pleural fluid biomarkers of MM can be elevated when serum levels remain normal. The aim of this study was to determine if this was true for MPF and to compare levels of mesothelin. Biomarker concentrations were compared in 66 MM patients, 39 patients with other malignancies, 37 with benign disease, 18 asbestos-exposed healthy individuals, and 53 patients with chronic kidney disease. In pleural effusions, MPF and soluble mesothelin concentrations were both significantly elevated in MM patients relative to controls. No significant difference between the area under the receiver operator curve (AUC for MPF (0.945±0.02 and mesothelin (0.928±0.03 when distinguishing MM from all other causes of effusion was observed. MPF and mesothelin serum concentrations were highly correlated and of equivalent diagnostic accuracy with AUCs of 0.813±0.04 and 0.829±0.03, respectively. Serum levels of both markers increased with decreasing kidney function. In conclusion, MPF is elevated in the pleural effusions of MM patients similar to that of mesothelin. Mesothelin and MPF convey equivalent diagnostic information for distinguishing MM from other diseases in pleural effusions as well as serum.

  12. Increased oral AUC of baicalin in streptozotocin-induced diabetic rats due to the increased activity of intestinal beta-glucuronidase.

    Science.gov (United States)

    Liu, Li; Deng, Yuan-Xiong; Liang, Yan; Pang, Xiao-Yan; Liu, Xiao-Dong; Liu, Yao-Wu; Yang, Jian-Song; Xie, Lin; Wang, Guang-Ji

    2010-01-01

    The purpose of the study was to investigate the pharmacokinetics of baicalin, a major bioactive component of Scutellariae radix, in diabetic conditions. The 4-week diabetic rats were induced by intraperitoneal administration of streptozotocin. Plasma concentrations of baicalin were measured following oral (200 mg/kg) or intravenous (12 mg/kg) administration. Everted intestinal transport, intestinal mucosal metabolism of baicalin and intestinal beta-glucuronidase activity were also investigated. It was found that the diabetic condition significantly increased the exposure of baicalin following oral doses (AUC 100.77 +/- 4.16 microg x h/mL in diabetic rats vs. 48.48 +/- 7.94 microg x h/mL in normal rats). In contrast, the diabetic condition significantly decreased the exposure of baicalin following intravenous doses (AUC 11.20 +/- 2.28 microg x h/mL in diabetic rats vs. 18.02 +/- 3.45 microg x h/mL in normal rats). We also found lower apparent permeability coefficients of baicalin in the ileum of diabetic rats (8.43 x 10 (-6) +/- 2.40 x 10 (-6) cm/s in diabetic rats vs. 5.21 x 10 (-5) +/- 1.55 x 10 (-5) cm/s in normal rats). Further studies showed that the diabetic condition enhanced the hydrolysis of baicalin to baicalein in intestinal mucosal, accompanied by an increase of beta-glucuronidase activity. All these results suggested that the higher oral exposure of baicalin in diabetic rats did not result from the decreased hepatic metabolism or increased intestinal absorption of baicalin. The enhancement of intestinal beta-glucuronidase activity may partly account for the higher exposure of baicalin in diabetic rats after oral administration. Copyright Georg Thieme Verlag KG Stuttgart . New York.

  13. The Analysis of Burrows Recognition Accuracy in XINJIANG'S Pasture Area Based on Uav Visible Images with Different Spatial Resolution

    Science.gov (United States)

    Sun, D.; Zheng, J. H.; Ma, T.; Chen, J. J.; Li, X.

    2018-04-01

    The rodent disaster is one of the main biological disasters in grassland in northern Xinjiang. The eating and digging behaviors will cause the destruction of ground vegetation, which seriously affected the development of animal husbandry and grassland ecological security. UAV low altitude remote sensing, as an emerging technique with high spatial resolution, can effectively recognize the burrows. However, how to select the appropriate spatial resolution to monitor the calamity of the rodent disaster is the first problem we need to pay attention to. The purpose of this study is to explore the optimal spatial scale on identification of the burrows by evaluating the impact of different spatial resolution for the burrows identification accuracy. In this study, we shoot burrows from different flight heights to obtain visible images of different spatial resolution. Then an object-oriented method is used to identify the caves, and we also evaluate the accuracy of the classification. We found that the highest classification accuracy of holes, the average has reached more than 80 %. At the altitude of 24 m and the spatial resolution of 1cm, the accuracy of the classification is the highest We have created a unique and effective way to identify burrows by using UAVs visible images. We draw the following conclusion: the best spatial resolution of burrows recognition is 1 cm using DJI PHANTOM-3 UAV, and the improvement of spatial resolution does not necessarily lead to the improvement of classification accuracy. This study lays the foundation for future research and can be extended to similar studies elsewhere.

  14. Optical biopsy of head and neck cancer using hyperspectral imaging and convolutional neural networks

    Science.gov (United States)

    Halicek, Martin; Little, James V.; Wang, Xu; Patel, Mihir; Griffith, Christopher C.; El-Deiry, Mark W.; Chen, Amy Y.; Fei, Baowei

    2018-02-01

    Successful outcomes of surgical cancer resection necessitate negative, cancer-free surgical margins. Currently, tissue samples are sent to pathology for diagnostic confirmation. Hyperspectral imaging (HSI) is an emerging, non-contact optical imaging technique. A reliable optical method could serve to diagnose and biopsy specimens in real-time. Using convolutional neural networks (CNNs) as a tissue classifier, we developed a method to use HSI to perform an optical biopsy of ex-vivo surgical specimens, collected from 21 patients undergoing surgical cancer resection. Training and testing on samples from different patients, the CNN can distinguish squamous cell carcinoma (SCCa) from normal aerodigestive tract tissues with an area under the curve (AUC) of 0.82, 81% accuracy, 81% sensitivity, and 80% specificity. Additionally, normal oral tissues can be sub-classified into epithelium, muscle, and glandular mucosa using a decision tree method, with an average AUC of 0.94, 90% accuracy, 93% sensitivity, and 89% specificity. After separately training on thyroid tissue, the CNN differentiates between thyroid carcinoma and normal thyroid with an AUC of 0.95, 92% accuracy, 92% sensitivity, and 92% specificity. Moreover, the CNN can discriminate medullary thyroid carcinoma from benign multi-nodular goiter (MNG) with an AUC of 0.93, 87% accuracy, 88% sensitivity, and 85% specificity. Classical-type papillary thyroid carcinoma is differentiated from benign MNG with an AUC of 0.91, 86% accuracy, 86% sensitivity, and 86% specificity. Our preliminary results demonstrate that an HSI-based optical biopsy method using CNNs can provide multi-category diagnostic information for normal head-and-neck tissue, SCCa, and thyroid carcinomas. More patient data are needed in order to fully investigate the proposed technique to establish reliability and generalizability of the work.

  15. The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy

    Directory of Open Access Journals (Sweden)

    Devillé Walter LJM

    2004-06-01

    Full Text Available Abstract Background Many studies have evaluated the accuracy of dipstick tests as rapid detectors of bacteriuria and urinary tract infections (UTI. The lack of an adequate explanation for the heterogeneity of the dipstick accuracy stimulates an ongoing debate. The objective of the present meta-analysis was to summarise the available evidence on the diagnostic accuracy of the urine dipstick test, taking into account various pre-defined potential sources of heterogeneity. Methods Literature from 1990 through 1999 was searched in Medline and Embase, and by reference tracking. Selected publications should be concerned with the diagnosis of bacteriuria or urinary tract infections, investigate the use of dipstick tests for nitrites and/or leukocyte esterase, and present empirical data. A checklist was used to assess methodological quality. Results 70 publications were included. Accuracy of nitrites was high in pregnant women (Diagnostic Odds Ratio = 165 and elderly people (DOR = 108. Positive predictive values were ≥80% in elderly and in family medicine. Accuracy of leukocyte-esterase was high in studies in urology patients (DOR = 276. Sensitivities were highest in family medicine (86%. Negative predictive values were high in both tests in all patient groups and settings, except for in family medicine. The combination of both test results showed an important increase in sensitivity. Accuracy was high in studies in urology patients (DOR = 52, in children (DOR = 46, and if clinical information was present (DOR = 28. Sensitivity was highest in studies carried out in family medicine (90%. Predictive values of combinations of positive test results were low in all other situations. Conclusions Overall, this review demonstrates that the urine dipstick test alone seems to be useful in all populations to exclude the presence of infection if the results of both nitrites and leukocyte-esterase are negative. Sensitivities of the combination of both tests vary

  16. The effect of the nonhuman external regulator’s answer-until-correct (AUC) versus knowledge-of-result (KR) task feedback on children’s behavioral regulation during learning tasks

    NARCIS (Netherlands)

    Agina, Adel Masaud; Agina, Adel M.; Kommers, Petrus A.M.; Steehouder, M.F.

    2011-01-01

    The present study was conducted to shed a new light on the nonhuman’s external regulation effect on children’s behavioral regulation through investigating the effect of the computer’s task feedback answer-until-correct (AUC) versus knowledge-of-result (KR) with 40 preschool children (boys/girls)

  17. Up to the highest peak!

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    In the early hours of this morning, the beam energy was ramped up to 3.5 TeV, a new world record and the highest energy for this year’s run. Now operators will prepare the machine to make high-energy collisions later this month. CERN Operations Group leader Mike Lamont (foreground) and LHC engineer in charge Alick Macpherson in the CERN Control Centre early this morning. At 5:23 this morning, Friday 19 March, the energy of both beams in the LHC was ramped up to 3.5 TeV, a new world record. During the night, operators had tested the performance of the whole machine with two so-called ‘dry runs’, that is, without beams. Given the good overall response, beams were injected at around 3:00 a.m. and stabilized soon after. The ramp started at around 4:10 and lasted about one hour. Over the last couple of weeks, operation of the LHC at 450 GeV has become routinely reproducible. The operators were able to test and optimize the beam orbit, the beam collimation, the injection and ext...

  18. On the validity of time-dependent AUC estimators.

    Science.gov (United States)

    Schmid, Matthias; Kestler, Hans A; Potapov, Sergej

    2015-01-01

    Recent developments in molecular biology have led to the massive discovery of new marker candidates for the prediction of patient survival. To evaluate the predictive value of these markers, statistical tools for measuring the performance of survival models are needed. We consider estimators of discrimination measures, which are a popular approach to evaluate survival predictions in biomarker studies. Estimators of discrimination measures are usually based on regularity assumptions such as the proportional hazards assumption. Based on two sets of molecular data and a simulation study, we show that violations of the regularity assumptions may lead to over-optimistic estimates of prediction accuracy and may therefore result in biased conclusions regarding the clinical utility of new biomarkers. In particular, we demonstrate that biased medical decision making is possible even if statistical checks indicate that all regularity assumptions are satisfied. © The Author 2013. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  19. Influence of optic disc size on the diagnostic performance of macular ganglion cell complex and peripapillary retinal nerve fiber layer analyses in glaucoma.

    Science.gov (United States)

    Cordeiro, Daniela Valença; Lima, Verônica Castro; Castro, Dinorah P; Castro, Leonardo C; Pacheco, Maria Angélica; Lee, Jae Min; Dimantas, Marcelo I; Prata, Tiago Santos

    2011-01-01

    To evaluate the influence of optic disc size on the diagnostic accuracy of macular ganglion cell complex (GCC) and conventional peripapillary retinal nerve fiber layer (pRNFL) analyses provided by spectral domain optical coherence tomography (SD-OCT) in glaucoma. Eighty-two glaucoma patients and 30 healthy subjects were included. All patients underwent GCC (7 × 7 mm macular grid, consisting of RNFL, ganglion cell and inner plexiform layers) and pRNFL thickness measurement (3.45 mm circular scan) by SD-OCT. One eye was randomly selected for analysis. Initially, receiver operating characteristic (ROC) curves were generated for different GCC and pRNFL parameters. The effect of disc area on the diagnostic accuracy of these parameters was evaluated using a logistic ROC regression model. Subsequently, 1.5, 2.0, and 2.5 mm(2) disc sizes were arbitrarily chosen (based on data distribution) and the predicted areas under the ROC curves (AUCs) and sensitivities were compared at fixed specificities for each. Average mean deviation index for glaucomatous eyes was -5.3 ± 5.2 dB. Similar AUCs were found for the best pRNFL (average thickness = 0.872) and GCC parameters (average thickness = 0.824; P = 0.19). The coefficient representing disc area in the ROC regression model was not statistically significant for average pRNFL thickness (-0.176) or average GCC thickness (0.088; P ≥ 0.56). AUCs for fixed disc areas (1.5, 2.0, and 2.5 mm(2)) were 0.904, 0.891, and 0.875 for average pRNFL thickness and 0.834, 0.842, and 0.851 for average GCC thickness, respectively. The highest sensitivities - at 80% specificity for average pRNFL (84.5%) and GCC thicknesses (74.5%) - were found with disc sizes fixed at 1.5 mm(2) and 2.5 mm(2). Diagnostic accuracy was similar between pRNFL and GCC thickness parameters. Although not statistically significant, there was a trend for a better diagnostic accuracy of pRNFL thickness measurement in cases of smaller discs. For GCC analysis, an inverse effect

  20. An automated method for the evaluation of the pointing accuracy of Sun-tracking devices

    Science.gov (United States)

    Baumgartner, Dietmar J.; Pötzi, Werner; Freislich, Heinrich; Strutzmann, Heinz; Veronig, Astrid M.; Rieder, Harald E.

    2017-03-01

    The accuracy of solar radiation measurements, for direct (DIR) and diffuse (DIF) radiation, depends significantly on the precision of the operational Sun-tracking device. Thus, rigid targets for instrument performance and operation have been specified for international monitoring networks, e.g., the Baseline Surface Radiation Network (BSRN) operating under the auspices of the World Climate Research Program (WCRP). Sun-tracking devices that fulfill these accuracy requirements are available from various instrument manufacturers; however, none of the commercially available systems comprise an automatic accuracy control system allowing platform operators to independently validate the pointing accuracy of Sun-tracking sensors during operation. Here we present KSO-STREAMS (KSO-SunTRackEr Accuracy Monitoring System), a fully automated, system-independent, and cost-effective system for evaluating the pointing accuracy of Sun-tracking devices. We detail the monitoring system setup, its design and specifications, and the results from its application to the Sun-tracking system operated at the Kanzelhöhe Observatory (KSO) Austrian radiation monitoring network (ARAD) site. The results from an evaluation campaign from March to June 2015 show that the tracking accuracy of the device operated at KSO lies within BSRN specifications (i.e., 0.1° tracking accuracy) for the vast majority of observations (99.8 %). The evaluation of manufacturer-specified active-tracking accuracies (0.02°), during periods with direct solar radiation exceeding 300 W m-2, shows that these are satisfied in 72.9 % of observations. Tracking accuracies are highest during clear-sky conditions and on days where prevailing clear-sky conditions are interrupted by frontal movement; in these cases, we obtain the complete fulfillment of BSRN requirements and 76.4 % of observations within manufacturer-specified active-tracking accuracies. Limitations to tracking surveillance arise during overcast conditions and

  1. Highest weight representations of the quantum algebra Uh(gl∞)

    International Nuclear Information System (INIS)

    Palev, T.D.; Stoilova, N.I.

    1997-04-01

    A class of highest weight irreducible representations of the quantum algebra U h (gl-∞) is constructed. Within each module a basis is introduced and the transformation relations of the basis under the action of the Chevalley generators are explicitly written. (author). 16 refs

  2. Differentiation of Brain Tumor Recurrence from Post-Radiotherapy Necrosis with 11C-Methionine PET: Visual Assessment versus Quantitative Assessment.

    Directory of Open Access Journals (Sweden)

    Ryogo Minamimoto

    Full Text Available The aim of this multi-center study was to assess the diagnostic capability of visual assessment in L-methyl-11C-methionine positron emission tomography (MET-PET for differentiating a recurrent brain tumor from radiation-induced necrosis after radiotherapy, and to compare it to the accuracy of quantitative analysis.A total of 73 brain lesions (glioma: 31, brain metastasis: 42 in 70 patients who underwent MET-PET were included in this study. Visual analysis was performed by comparison of MET uptake in the brain lesion with MET uptake in one of four regions (around the lesion, contralateral frontal lobe, contralateral area, and contralateral cerebellar cortex. The concordance rate and logistic regression analysis were used to evaluate the diagnostic ability of visual assessment. Receiver-operating characteristic curve analysis was used to compare visual assessment with quantitative assessment based on the lesion-to-normal (L/N ratio of MET uptake.Interobserver and intraobserver κ-values were highest at 0.657 and 0.714, respectively, when assessing MET uptake in the lesion compared to that in the contralateral cerebellar cortex. Logistic regression analysis showed that assessing MET uptake in the contralateral cerebellar cortex with brain metastasis was significantly related to the final result. The highest area under the receiver-operating characteristic curve (AUC with visual assessment for brain metastasis was 0.85, showing no statistically significant difference with L/Nmax of the contralateral brain (AUC = 0.89 or with L/Nmean of the contralateral cerebellar cortex (AUC = 0.89, which were the areas that were the highest in the quantitative assessment. For evaluation of gliomas, no specific candidate was confirmed among the four areas used in visual assessment, and no significant difference was seen between visual assessment and quantitative assessment.The visual assessment showed no significant difference from quantitative assessment of MET

  3. Two Clock Transitions in Neutral Yb for the Highest Sensitivity to Variations of the Fine-Structure Constant

    Science.gov (United States)

    Safronova, Marianna S.; Porsev, Sergey G.; Sanner, Christian; Ye, Jun

    2018-04-01

    We propose a new frequency standard based on a 4 f146 s 6 p P0 3 -4 f136 s25 d (J =2 ) transition in neutral Yb. This transition has a potential for high stability and accuracy and the advantage of the highest sensitivity among atomic clocks to variation of the fine-structure constant α . We find its dimensionless α -variation enhancement factor to be K =-15 , in comparison to the most sensitive current clock (Yb+ E 3 , K =-6 ), and it is 18 times larger than in any neutral-atomic clocks (Hg, K =0.8 ). Combined with the unprecedented stability of an optical lattice clock for neutral atoms, this high sensitivity opens new perspectives for searches for ultralight dark matter and for tests of theories beyond the standard model of elementary particles. Moreover, together with the well-established 1S0-3P0 transition, one will have two clock transitions operating in neutral Yb, whose interleaved interrogations may further reduce systematic uncertainties of such clock-comparison experiments.

  4. Improving prediction accuracy of cooling load using EMD, PSR and RBFNN

    Science.gov (United States)

    Shen, Limin; Wen, Yuanmei; Li, Xiaohong

    2017-08-01

    To increase the accuracy for the prediction of cooling load demand, this work presents an EMD (empirical mode decomposition)-PSR (phase space reconstruction) based RBFNN (radial basis function neural networks) method. Firstly, analyzed the chaotic nature of the real cooling load demand, transformed the non-stationary cooling load historical data into several stationary intrinsic mode functions (IMFs) by using EMD. Secondly, compared the RBFNN prediction accuracies of each IMFs and proposed an IMF combining scheme that is combine the lower-frequency components (called IMF4-IMF6 combined) while keep the higher frequency component (IMF1, IMF2, IMF3) and the residual unchanged. Thirdly, reconstruct phase space for each combined components separately, process the highest frequency component (IMF1) by differential method and predict with RBFNN in the reconstructed phase spaces. Real cooling load data of a centralized ice storage cooling systems in Guangzhou are used for simulation. The results show that the proposed hybrid method outperforms the traditional methods.

  5. Accuracy of cystatin C for the detection of abnormal renal function in children undergoing chemotherapy for malignancy: a systematic review using individual patient data.

    Science.gov (United States)

    Whiting, Penny; Birnie, Kate; Sterne, Jonathan A C; Jameson, Catherine; Skinner, Rod; Phillips, Bob

    2018-05-01

    We conducted a systematic review and individual patient data (IPD) meta-analysis to examine the utility of cystatin C for evaluation of glomerular function in children with cancer. Eligible studies evaluated the accuracy of cystatin C for detecting poor renal function in children undergoing chemotherapy. Study quality was assessed using QUADAS-2. Authors of four studies shared IPD. We calculated the correlation between log cystatin C and GFR stratified by study and measure of cystatin C. We dichotomized the reference standard at GFR 80 ml/min/1.73m 2 and stratified cystatin C at 1 mg/l, to calculate sensitivity and specificity in each study and according to age group (0-4, 5-12, and ≥ 13 years). In sensitivity analyses, we investigated different GFR and cystatin C cut points. We used logistic regression to estimate the association of impaired renal function with log cystatin C and quantified diagnostic accuracy using the area under the ROC curve (AUC). Six studies, which used different test and reference standard thresholds, suggested that cystatin C has the potential to monitor renal function in children undergoing chemotherapy for malignancy. IPD data (504 samples, 209 children) showed that cystatin C has poor sensitivity (63%) and moderate specificity (89%), although use of a GFR cut point of C has better diagnostic accuracy than creatinine as a test for glomerular dysfunction in young people undergoing treatment for cancer. Diagnostic accuracy is not sufficient for it to replace current reference standards for predicting clinically relevant impairments that may alter dosing of important nephrotoxic agents.

  6. Differentiation of prostate cancer lesions with high and with low Gleason score by diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Barbieri, Sebastiano; Broennimann, Michael; Vermathen, Peter; Thoeny, Harriet C. [Inselspital University Hospital, Institute of Diagnostic, Pediatric, and Interventional Radiology, Bern (Switzerland); Boxler, Silvan [Inselspital, Inselspital University Hospital, Department of Urology, Bern (Switzerland)

    2017-04-15

    To differentiate prostate cancer lesions with high and with low Gleason score by diffusion-weighted-MRI (DW-MRI). This prospective study was approved by the responsible ethics committee. DW-MRI of 84 consenting prostate and/or bladder cancer patients scheduled for radical prostatectomy were acquired and used to compute apparent diffusion coefficient (ADC), intravoxel incoherent motion (IVIM: the pure diffusion coefficient D{sub t}, the pseudo-diffusion fraction F{sub p} and the pseudo-diffusion coefficient D{sub p}), and high b value (as acquired and Hessian filtered) parameters within the index lesion. These parameters (separately and combined in a logistic regression model) were used to differentiate lesions depending on whether whole-prostate histopathological analysis after prostatectomy determined a high (≥7) or low (6) Gleason score. Mean ADC and D{sub t} differed significantly (p of independent two-sample t test < 0.01) between high- and low-grade lesions. The highest classification accuracy was achieved by the mean ADC (AUC 0.74) and D{sub t} (AUC 0.70). A logistic regression model based on mean ADC, mean F{sub p} and mean high b value image led to an AUC of 0.74 following leave-one-out cross-validation. Classification by IVIM parameters was not superior to classification by ADC. DW-MRI parameters correlated with Gleason score but did not provide sufficient information to classify individual patients. (orig.)

  7. A minimally invasive system for glucose area under the curve measurement using interstitial fluid extraction technology: evaluation of the accuracy and usefulness with oral glucose tolerance tests in subjects with and without diabetes.

    Science.gov (United States)

    Sakaguchi, Kazuhiko; Hirota, Yushi; Hashimoto, Naoko; Ogawa, Wataru; Sato, Toshiyuki; Okada, Seiki; Hagino, Kei; Asakura, Yoshihiro; Kikkawa, Yasuo; Kojima, Junko; Maekawa, Yasunori; Nakajima, Hiromu

    2012-06-01

    Recent studies have highlighted the importance of managing postprandial hyperglycemia, but adequate monitoring of postprandial glucose remains difficult because of wide variations in levels. We have therefore developed a minimally invasive system to monitor postprandial glucose area under the curve (AUC). This system involves no blood sampling and uses interstitial fluid glucose (IG) AUC (IG-AUC) as a surrogate marker of postprandial glucose. This study aimed to evaluate the usefulness of this system by comparing data with the findings of oral glucose tolerance tests (OGTTs) in subjects with and without diabetes. The glucose AUC monitoring system was validated by OGTTs in 37 subjects with and 10 subjects without diabetes. A plastic microneedle array was stamped on the forearm to extract IG. A hydrogel patch was then placed on the pretreated area to accumulate IG. Glucose and sodium ion concentrations in the hydrogel were measured to calculate IG-AUC at 2-h postload glucose. Plasma glucose (PG) levels were measured every 30 min to calculate reference PG-AUC. IG-AUC correlated strongly with reference PG-AUC (r=0.93) over a wide range. The level of correlation between IG-AUC and maximum PG level was also high (r=0.86). The painless nature of the technique was confirmed by the response of patients to questionnaires. The glucose AUC monitoring system using IG provided good estimates of reference PG-AUC and maximum PG level during OGTTs in subjects with and without diabetes. This system provides easy-to-use monitoring of glucose AUC, which is a good indicator of postprandial glucose.

  8. Lung Cancer Screening May Benefit Those at Highest Risk

    Science.gov (United States)

    People at the highest risk for lung cancer, based on a risk model, may be more likely to benefit from screening with low-dose CT, a new analysis suggests. The study authors believe the findings may better define who should undergo lung cancer screening, as this Cancer Currents blog post explains.

  9. Volume perfusion CT imaging of cerebral vasospasm: diagnostic performance of different perfusion maps

    Energy Technology Data Exchange (ETDEWEB)

    Othman, Ahmed E. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Radiology, Tuebingen (Germany); Afat, Saif; Nikoubashman, Omid; Mueller, Marguerite; Wiesmann, Martin; Brockmann, Carolin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Schubert, Gerrit Alexander [RWTH Aachen University, Department of Neurosurgery, Aachen (Germany); Bier, Georg [Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Brockmann, Marc A. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); University Hospital Mainz, Department of Neuroradiology, Mainz (Germany)

    2016-08-15

    In this study, we aimed to evaluate the diagnostic performance of different volume perfusion CT (VPCT) maps regarding the detection of cerebral vasospasm compared to angiographic findings. Forty-one datasets of 26 patients (57.5 ± 10.8 years, 18 F) with subarachnoid hemorrhage and suspected cerebral vasospasm, who underwent VPCT and angiography within 6 h, were included. Two neuroradiologists independently evaluated the presence and severity of vasospasm on perfusion maps on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting <50 %, 2 - vasospasm affecting >50 % of vascular territory). A third neuroradiologist independently assessed angiography for the presence and severity of vasospasm on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting < 50 %, 2 - vasospasm affecting > 50 % of vessel diameter). Perfusion maps of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and time to drain (TTD) were evaluated regarding diagnostic accuracy for cerebral vasospasm with angiography as reference standard. Correlation analysis of vasospasm severity on perfusion maps and angiographic images was performed. Furthermore, inter-reader agreement was assessed regarding findings on perfusion maps. Diagnostic accuracy for TTD and MTT was significantly higher than for all other perfusion maps (TTD, AUC = 0.832; MTT, AUC = 0.791; p < 0.001). TTD revealed higher sensitivity than MTT (p = 0.007). The severity of vasospasm on TTD maps showed significantly higher correlation levels with angiography than all other perfusion maps (p ≤ 0.048). Inter-reader agreement was (almost) perfect for all perfusion maps (kappa ≥ 0.927). The results of this study indicate that TTD maps have the highest sensitivity for the detection of cerebral vasospasm and highest correlation with angiography regarding the severity of vasospasm. (orig.)

  10. Modeling the UO2 ex-AUC pellet process and predicting the fuel rod temperature distribution under steady-state operating condition

    Science.gov (United States)

    Hung, Nguyen Trong; Thuan, Le Ba; Thanh, Tran Chi; Nhuan, Hoang; Khoai, Do Van; Tung, Nguyen Van; Lee, Jin-Young; Jyothi, Rajesh Kumar

    2018-06-01

    Modeling uranium dioxide pellet process from ammonium uranyl carbonate - derived uranium dioxide powder (UO2 ex-AUC powder) and predicting fuel rod temperature distribution were reported in the paper. Response surface methodology (RSM) and FRAPCON-4.0 code were used to model the process and to predict the fuel rod temperature under steady-state operating condition. Fuel rod design of AP-1000 designed by Westinghouse Electric Corporation, in these the pellet fabrication parameters are from the study, were input data for the code. The predictive data were suggested the relationship between the fabrication parameters of UO2 pellets and their temperature image in nuclear reactor.

  11. The highest energy cosmic rays, photons and neutrinos

    International Nuclear Information System (INIS)

    Zas, Enrique

    1998-01-01

    In these lectures I introduce and discuss aspects of currently active fields of interest related to the production, transport and detection of high energy particles from extraterrestrial sources. I have payed most attention to the highest energies and I have divided the material according to the types of particles which will be searched for with different experimental facilities in planning: hadrons, gamma rays and neutrinos. Particular attention is given to shower development, stochastic acceleration and detection techniques

  12. Practical determination of aortic valve calcium volume score on contrast-enhanced computed tomography prior to transcatheter aortic valve replacement and impact on paravalvular regurgitation: Elucidating optimal threshold cutoffs.

    Science.gov (United States)

    Bettinger, Nicolas; Khalique, Omar K; Krepp, Joseph M; Hamid, Nadira B; Bae, David J; Pulerwitz, Todd C; Liao, Ming; Hahn, Rebecca T; Vahl, Torsten P; Nazif, Tamim M; George, Isaac; Leon, Martin B; Einstein, Andrew J; Kodali, Susheel K

    The threshold for the optimal computed tomography (CT) number in Hounsfield Units (HU) to quantify aortic valvular calcium on contrast-enhanced scans has not been standardized. Our aim was to find the most accurate threshold to predict paravalvular regurgitation (PVR) after transcatheter aortic valve replacement (TAVR). 104 patients who underwent TAVR with the CoreValve prosthesis were studied retrospectively. Luminal attenuation (LA) in HU was measured at the level of the aortic annulus. Calcium volume score for the aortic valvular complex was measured using 6 threshold cutoffs (650 HU, 850 HU, LA × 1.25, LA × 1.5, LA+50, LA+100). Receiver-operating characteristic (ROC) analysis was performed to assess the predictive value for > mild PVR (n = 16). Multivariable analysis was performed to determine the accuracy to predict > mild PVR after adjustment for depth and perimeter oversizing. ROC analysis showed lower area under the curve (AUC) values for fixed threshold cutoffs (650 or 850 HU) compared to thresholds relative to LA. The LA+100 threshold had the highest AUC (0.81), and AUC was higher than all studied protocols, other than the LA x 1.25 and LA + 50 protocols, where the difference approached statistical significance (p = 0.05, and 0.068, respectively). Multivariable analysis showed calcium volume determined by the LAx1.25, LAx1.5, LA+50, and LA+ 100 HU protocols to independently predict PVR. Calcium volume scoring thresholds which are relative to LA are more predictive of PVR post-TAVR than those which use fixed cutoffs. A threshold of LA+100 HU had the highest predictive value. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  13. Non-small cell lung cancer: Whole-lesion histogram analysis of the apparent diffusion coefficient for assessment of tumor grade, lymphovascular invasion and pleural invasion.

    Science.gov (United States)

    Tsuchiya, Naoko; Doai, Mariko; Usuda, Katsuo; Uramoto, Hidetaka; Tonami, Hisao

    2017-01-01

    Investigating the diagnostic accuracy of histogram analyses of apparent diffusion coefficient (ADC) values for determining non-small cell lung cancer (NSCLC) tumor grades, lymphovascular invasion, and pleural invasion. We studied 60 surgically diagnosed NSCLC patients. Diffusion-weighted imaging (DWI) was performed in the axial plane using a navigator-triggered single-shot, echo-planar imaging sequence with prospective acquisition correction. The ADC maps were generated, and we placed a volume-of-interest on the tumor to construct the whole-lesion histogram. Using the histogram, we calculated the mean, 5th, 10th, 25th, 50th, 75th, 90th, and 95th percentiles of ADC, skewness, and kurtosis. Histogram parameters were correlated with tumor grade, lymphovascular invasion, and pleural invasion. We performed a receiver operating characteristics (ROC) analysis to assess the diagnostic performance of histogram parameters for distinguishing different pathologic features. The ADC mean, 10th, 25th, 50th, 75th, 90th, and 95th percentiles showed significant differences among the tumor grades. The ADC mean, 25th, 50th, 75th, 90th, and 95th percentiles were significant histogram parameters between high- and low-grade tumors. The ROC analysis between high- and low-grade tumors showed that the 95th percentile ADC achieved the highest area under curve (AUC) at 0.74. Lymphovascular invasion was associated with the ADC mean, 50th, 75th, 90th, and 95th percentiles, skewness, and kurtosis. Kurtosis achieved the highest AUC at 0.809. Pleural invasion was only associated with skewness, with the AUC of 0.648. ADC histogram analyses on the basis of the entire tumor volume are able to stratify NSCLCs' tumor grade, lymphovascular invasion and pleural invasion.

  14. GFR prediction from cystatin C and creatinine in children: body cell mass increases accuracy of the estimate

    DEFF Research Database (Denmark)

    Andersen, Trine Borup; Jødal, Lars; Bøgsted, Martin

    ) aged 2-14 years (mean 8.8 years). GFR was 14-147 mL/min/1.73m2 (mean 97 mL/min/1.73m2). BCM was estimated using bioimpedance spectroscopy (Xitron Hydra 4200). Log-transformed data on BCM/CysC, serum creatinine (SCr), body-surface-area (BSA), height x BSA/SCr, serum CysC, weight, sex, age, height, serum....... The present equation also had the highest R2 and the narrowest 95% limits of agreement. CONCLUSION: The new equation predicts GFR with higher accuracy than other equations. Endogenous methods are, however, still not accurate enough to replace exogenous markers when GFR must be determined with high accuracy...

  15. Origin of the highest energy cosmic rays

    Energy Technology Data Exchange (ETDEWEB)

    Biermann, Peter L.; Ahn, Eun-Joo; Medina-Tanco, Gustavo; Stanev, Todor

    2000-06-01

    Introducing a simple Galactic wind model patterned after the solar wind we show that back-tracing the orbits of the highest energy cosmic events suggests that they may all come from the Virgo cluster, and so probably from the active radio galaxy M87. This confirms a long standing expectation. Those powerful radio galaxies that have their relativistic jets stuck in the interstellar medium of the host galaxy, such as 3C147, will then enable us to derive limits on the production of any new kind of particle, expected in some extensions of the standard model in particle physics. New data from HIRES will be crucial in testing the model proposed here.

  16. Incretin responses to oral glucose and mixed meal tests and changes in fasting glucose levels during 7 years of follow-up

    DEFF Research Database (Denmark)

    Koopman, A D M; Rutters, F; Rauh, S P

    2018-01-01

    . We used data from the Hoorn Meal Study; a population-based cohort study among 121 subjects, aged 61.0±6.7y. GIP and GLP-1 responses were determined at baseline and expressed as total and incremental area under the curve (tAUC and iAUC). The association between incretin response at baseline...... and changes in fasting glucose levels was assessed using linear regression. The average change in glucose over 7 years was 0.43 ± 0.5 mmol/l. For GIP, no significant associations were observed with changes in fasting glucose levels. In contrast, participants within the middle and highest tertile of GLP-1 iAUC...... responses to OGTT had significantly smaller increases (actually decreases) in fasting glucose levels; -0.28 (95% confidence interval: -0.54;-0.01) mmol/l and -0.39 (-0.67;-0.10) mmol/l, respectively, compared to those in the lowest tertile. The same trend was observed for tAUC GLP-1 following OGTT (highest...

  17. A new derivation of the highest-weight polynomial of a unitary lie algebra

    International Nuclear Information System (INIS)

    P Chau, Huu-Tai; P Van, Isacker

    2000-01-01

    A new method is presented to derive the expression of the highest-weight polynomial used to build the basis of an irreducible representation (IR) of the unitary algebra U(2J+1). After a brief reminder of Moshinsky's method to arrive at the set of equations defining the highest-weight polynomial of U(2J+1), an alternative derivation of the polynomial from these equations is presented. The method is less general than the one proposed by Moshinsky but has the advantage that the determinantal expression of the highest-weight polynomial is arrived at in a direct way using matrix inversions. (authors)

  18. Accuracy of repeated measurements of late-night salivary cortisol to screen for early-stage recurrence of Cushing's disease following pituitary surgery.

    Science.gov (United States)

    Danet-Lamasou, Marie; Asselineau, Julien; Perez, Paul; Vivot, Alexandre; Nunes, Marie-Laure; Loiseau, Hugues; San-Galli, François; Cherifi-Gatta, Blandine; Corcuff, Jean-Benoît; Tabarin, Antoine

    2015-02-01

    The performance of late-night salivary cortisol (LNSC) to accurately screen for postoperative recurrence of Cushing's disease (CD) at an early stage is unknown. The aim of this study was to compare the accuracy of multiple sampling strategies to suggest the optimal number of LNSC samples needed for diagnosing post-surgical recurrences of CD at an early stage. Retrospective analysis in a single centre. Thirty-six patients in surgical remission of CD had successive measurements of LNSC, defined as 'sequences', using a locally modified RIA assay as part of long-term follow-up (69·2 ± 10·6 months). Patients underwent an extensive biochemical evaluation within 3 months before or after a sequence of saliva sampling and were classified as being in remission or in early-stage recurrence. The accuracy of three diagnostic strategies combining two, three or four LNSC results from a sequence was estimated using areas under the ROC curves (AUC), sensitivity, specificity and predictive values. Forty-four sequences of LNSC measurements were available. Fifty-two percent of sequences were performed during early-stage recurrence. The intrasequence variability of LNSC was higher during recurrence than during remission (medians of SDs: 2·1 vs 0·5 nm; P recurrence of CD. However, due to a major within-patient variability of LNSC from 1 day to another, a screening strategy using three or four samples collected on successive days may be recommended to detect early-stage recurrence of CD with a high accuracy. © 2014 John Wiley & Sons Ltd.

  19. Quantitative forecasting of PTSD from early trauma responses: A Machine Learning application

    DEFF Research Database (Denmark)

    Galatzer-Levy, I. R.; Karstoft, K. I.; Statnikov, A.

    2014-01-01

    -traumatic stress disorder (PTSD) is plausible given the disorder's salient onset and the abundance of putative biological and clinical risk indicators. This work evaluates the ability of Machine Learning (ML) forecasting approaches to identify and integrate a panel of unique predictive characteristics...... algorithm identified a set of predictors that rendered all others redundant. Support Vector Machines (SVMs) as well as other ML classification algorithms were used to evaluate the forecasting accuracy of i) ML selected features, ii) all available features without selection, and iii) Acute Stress Disorder......). The feature selection algorithm identified 16 predictors, present in >= 95% cross-validation trials. The accuracy of predicting non-remitting PTSD from that set (AUC = .77) did not differ from predicting from all available information (AUC = .78). Predicting from ASD symptoms was not better then chance (AUC...

  20. Accuracy and Precision of a Plane Wave Vector Flow Imaging Method in the Healthy Carotid Artery

    DEFF Research Database (Denmark)

    Jensen, Jonas; Villagómez Hoyos, Carlos Armando; Traberg, Marie Sand

    2018-01-01

    The objective of the study described here was to investigate the accuracy and precision of a plane wave 2-D vector flow imaging (VFI) method in laminar and complex blood flow conditions in the healthy carotid artery. The approach was to study (i) the accuracy for complex flow by comparing...... of laminar flow in vivo. The precision in vivo was calculated as the mean standard deviation (SD) of estimates aligned to the heart cycle and was highest in the center of the common carotid artery (SD = 3.6% for velocity magnitudes and 4.5° for angles) and lowest in the external branch and for vortices (SD...... the velocity field from a computational fluid dynamics (CFD) simulation to VFI estimates obtained from the scan of an anthropomorphic flow phantom and from an in vivo scan; (ii) the accuracy for laminar unidirectional flow in vivo by comparing peak systolic velocities from VFI with magnetic resonance...

  1. The fifty highest cited papers in anterior cruciate ligament injury.

    Science.gov (United States)

    Vielgut, Ines; Dauwe, Jan; Leithner, Andreas; Holzer, Lukas A

    2017-07-01

    The anterior cruciate ligament (ACL) is one of the most common injured knee ligaments and at the same time, one of the most frequent injuries seen in the sport orthopaedic practice. Due to the clinical relevance of ACL injuries, numerous papers focussing on this topic including biomechanical-, basic science-, clinical- or animal studies, were published. The purpose of this study was to determine the most frequently cited scientific articles which address this subject, establish a ranking of the 50 highest cited papers and analyse them according to their characteristics. The 50 highest cited articles related to Anterior Cruciate Ligament Injury were searched in Thomson ISI Web of Science® by the use of defined search terms. All types of scientific papers with reference to our topic were ranked according to the absolute number of citations and analyzed for the following characteristics: journal title, year of publication, number of citations, citation density, geographic origin, article type and level of evidence. The 50 highest cited articles had up to 1624 citations. The top ten papers on this topic were cited 600 times at least. Most papers were published in the American Journal of Sports Medicine. The publication years spanned from 1941 to 2007, with the 1990s and 2000s accounting for half of the articles (n = 25). Seven countries contributed to the top 50 list, with the USA having by far the most contribution (n = 40). The majority of articles could be attributed to the category "Clinical Science & Outcome". Most of them represent a high level of evidence. Scientific articles in the field of ACL injury are highly cited. The majority of these articles are clinical studies that have a high level of evidence. Although most of the articles were published between 1990 and 2007, the highest cited articles in absolute and relative numbers were published in the early 1980s. These articles contain well established scoring- or classification systems. The

  2. A phase I study of PRO131921, a novel anti-CD20 monoclonal antibody in patients with relapsed/refractory CD20+ indolent NHL: correlation between clinical responses and AUC pharmacokinetics.

    Science.gov (United States)

    Casulo, Carla; Vose, Julie M; Ho, William Y; Kahl, Brad; Brunvand, Mark; Goy, Andre; Kasamon, Yvette; Cheson, Bruce; Friedberg, Jonathan W

    2014-09-01

    PRO131921 is a third-generation, humanized anti-CD20 monoclonal antibody with increased antibody-dependent cytotoxicity and complement-dependent cytotoxicity compared to rituximab. In this phase I study, PRO131921 was administered as a single agent to patients with CD20+, relapsed or refractory, indolent non-Hodgkin lymphoma (NHL) who had been treated with a prior rituximab-containing regimen. The primary aim of this study was safety and tolerability of PRO131921. The secondary aim of the study, and focus of this report, was to determine the pharmacokinetics (PK) profile of PRO131921 and establish a correlation between drug exposure and clinical efficacy. Patients were treated with PRO131921 by intravenous infusion weekly for 4 weeks and the dose was escalated based on safety in a 3+3 design. Twenty-four patients were treated with PRO131921 at doses from 25mg/m(2) to 800 mg/m(2). Analysis of PK data demonstrated a correlation between higher normalized drug exposure (normalized AUC) and tumor shrinkage (p = .0035). Also, normalized AUC levels were higher among responders and subjects displaying tumor shrinkage versus subjects progressing or showing no regression (p = 0.030). In conclusion, PRO131921 demonstrated clinical activity in rituximab-relapsed and refractory indolent NHL patients. The observation that higher normalized AUC may be associated with improved clinical responses has potential implications in future trials of monoclonal antibody-based therapies, and emphasizes the importance of early PK studies to optimize antibody efficacy. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Diagnostic accuracy of ultrasound in upper and lower extremity long bone fractures of emergency department trauma patients.

    Science.gov (United States)

    Frouzan, Arash; Masoumi, Kambiz; Delirroyfard, Ali; Mazdaie, Behnaz; Bagherzadegan, Elnaz

    2017-08-01

    Long bone fractures are common injuries caused by trauma. Some studies have demonstrated that ultrasound has a high sensitivity and specificity in the diagnosis of upper and lower extremity long bone fractures. The aim of this study was to determine the accuracy of ultrasound compared with plain radiography in diagnosis of upper and lower extremity long bone fractures in traumatic patients. This cross-sectional study assessed 100 patients admitted to the emergency department of Imam Khomeini Hospital, Ahvaz, Iran with trauma to the upper and lower extremities, from September 2014 through October 2015. In all patients, first ultrasound and then standard plain radiography for the upper and lower limb was performed. Data were analyzed by SPSS version 21 to determine the specificity and sensitivity. The mean age of patients with upper and lower limb trauma were 31.43±12.32 years and 29.63±5.89 years, respectively. Radius fracture was the most frequent compared to other fractures (27%). Sensitivity, specificity, positive predicted value, and negative predicted value of ultrasound compared with plain radiography in the diagnosis of upper extremity long bones were 95.3%, 87.7%, 87.2% and 96.2%, respectively, and the highest accuracy was observed in left arm fractures (100%). Tibia and fibula fractures were the most frequent types compared to other fractures (89.2%). Sensitivity, specificity, PPV and NPV of ultrasound compared with plain radiography in the diagnosis of upper extremity long bone fractures were 98.6%, 83%, 65.4% and 87.1%, respectively, and the highest accuracy was observed in men, lower ages and femoral fractures. The results of this study showed that ultrasound compared with plain radiography has a high accuracy in the diagnosis of upper and lower extremity long bone fractures.

  4. Continuous electroencephalography predicts delayed cerebral ischemia after subarachnoid hemorrhage: A prospective study of diagnostic accuracy.

    Science.gov (United States)

    Rosenthal, Eric S; Biswal, Siddharth; Zafar, Sahar F; O'Connor, Kathryn L; Bechek, Sophia; Shenoy, Apeksha V; Boyle, Emily J; Shafi, Mouhsin M; Gilmore, Emily J; Foreman, Brandon P; Gaspard, Nicolas; Leslie-Mazwi, Thabele M; Rosand, Jonathan; Hoch, Daniel B; Ayata, Cenk; Cash, Sydney S; Cole, Andrew J; Patel, Aman B; Westover, M Brandon

    2018-04-16

    Delayed cerebral ischemia (DCI) is a common, disabling complication of subarachnoid hemorrhage (SAH). Preventing DCI is a key focus of neurocritical care, but interventions carry risk and cannot be applied indiscriminately. Although retrospective studies have identified continuous electroencephalographic (cEEG) measures associated with DCI, no study has characterized the accuracy of cEEG with sufficient rigor to justify using it to triage patients to interventions or clinical trials. We therefore prospectively assessed the accuracy of cEEG for predicting DCI, following the Standards for Reporting Diagnostic Accuracy Studies. We prospectively performed cEEG in nontraumatic, high-grade SAH patients at a single institution. The index test consisted of clinical neurophysiologists prospectively reporting prespecified EEG alarms: (1) decreasing relative alpha variability, (2) decreasing alpha-delta ratio, (3) worsening focal slowing, or (4) late appearing epileptiform abnormalities. The diagnostic reference standard was DCI determined by blinded, adjudicated review. Primary outcome measures were sensitivity and specificity of cEEG for subsequent DCI, determined by multistate survival analysis, adjusted for baseline risk. One hundred three of 227 consecutive patients were eligible and underwent cEEG monitoring (7.7-day mean duration). EEG alarms occurred in 96.2% of patients with and 19.6% without subsequent DCI (1.9-day median latency, interquartile range = 0.9-4.1). Among alarm subtypes, late onset epileptiform abnormalities had the highest predictive value. Prespecified EEG findings predicted DCI among patients with low (91% sensitivity, 83% specificity) and high (95% sensitivity, 77% specificity) baseline risk. cEEG accurately predicts DCI following SAH and may help target therapies to patients at highest risk of secondary brain injury. Ann Neurol 2018. © 2018 American Neurological Association.

  5. Application of multi-SNP approaches Bayesian LASSO and AUC-RF to detect main effects of inflammatory-gene variants associated with bladder cancer risk.

    Directory of Open Access Journals (Sweden)

    Evangelina López de Maturana

    Full Text Available The relationship between inflammation and cancer is well established in several tumor types, including bladder cancer. We performed an association study between 886 inflammatory-gene variants and bladder cancer risk in 1,047 cases and 988 controls from the Spanish Bladder Cancer (SBC/EPICURO Study. A preliminary exploration with the widely used univariate logistic regression approach did not identify any significant SNP after correcting for multiple testing. We further applied two more comprehensive methods to capture the complexity of bladder cancer genetic susceptibility: Bayesian Threshold LASSO (BTL, a regularized regression method, and AUC-Random Forest, a machine-learning algorithm. Both approaches explore the joint effect of markers. BTL analysis identified a signature of 37 SNPs in 34 genes showing an association with bladder cancer. AUC-RF detected an optimal predictive subset of 56 SNPs. 13 SNPs were identified by both methods in the total population. Using resources from the Texas Bladder Cancer study we were able to replicate 30% of the SNPs assessed. The associations between inflammatory SNPs and bladder cancer were reexamined among non-smokers to eliminate the effect of tobacco, one of the strongest and most prevalent environmental risk factor for this tumor. A 9 SNP-signature was detected by BTL. Here we report, for the first time, a set of SNP in inflammatory genes jointly associated with bladder cancer risk. These results highlight the importance of the complex structure of genetic susceptibility associated with cancer risk.

  6. Accuracy of non-fasting lipid profile for the assessment of lipoprotein coronary risk

    International Nuclear Information System (INIS)

    Fatima, S.; Ijaz, A.; Sharif, T.; Khan, D.A.; Siddique, A.

    2016-01-01

    To determine the diagnostic accuracy of non-fasting lipid profile in the diagnosis of hyperlipidemia, taking fasting lipid profile as gold standard, in adult population. Study Design: Cross sectional validation study. Place and Duration of Study: Department of chemical pathology and endocrinology, armed forces institute of pathology, rawalpindi, from july to december 2014. Methodology: One hundred seventy five adult patients coming for fasting lipid prodile were included; their non-fasting samples were taken on the next day. patients on anti-cholesterol treatment and indoor patients were excluded. Total cholesterol (TC), high density lipoprotein-cholestrol (HDL-C), and triglycerides were measured by direct enzymatic calorimetric method by modular p-800 rate. Low density lipoprotein-cholesterol (LDL-C) was calculated by friendewald's formula but when triglyceride was greater than 4.5mol/l, then LDL-C was measured directly by homogenous enzymatic colorimetric method. non-fasting lipid profile had 93% specificity, 51% sensitivity, 94% positive predictive value and 49% negative predictive value and 65% accuracy with 7.28 positive likehood ratio and 0.52 negative likelihood ratio. Non fasting TC and non-HDLC were significantly higher than fasting TC and non-HDL-c by mean difference of 0.2 mmol/l each with p=0.001 and p=0.004, respectively. fasting and on fasting HDLC-are comparable to each other with mean difference of 0.01 mmol/l (p=0.745) Receiver operating curve (ROC) of non fasting non HDLC-C showed 0.84 (95% Cl (0.738-0.870), p=0.000) area under the curve (AUC) indicating that it was a significant test for ruling out hyperlipdemia. Bland-altmann plot showed a significant difference between non fasting, non HDLC-C and fasting LDL-C and non fasting, non-HDL-C -0.087540 with base -0.00109; therefore, these cannot be alternative to each other. Conclusion: Diagnostic accuracy of non-fasting lipid profile was found significantly higher than fasting lipid profile (p=0

  7. Usefulness of a simple self-administered joint condition assessment sheet to predict the need for orthopaedic intervention in the management of haemophilic arthropathy.

    Science.gov (United States)

    Masaoka, T; Amano, K; Takedani, H; Suzuki, T; Otaki, M; Seita, I; Tateiwa, T; Shishido, T; Yamamoto, K; Fukutake, K

    2017-03-01

    Detecting signs of joint deterioration is important for early effective orthopaedic intervention in managing haemophilic arthropathy. We developed a simple, patient self-administered sheet to evaluate the joint condition, and assessed the predictive ability of this assessment sheet for the need for an orthopaedic intervention. This was a single-centre, cross-sectional study. The association between the score of each of the four items of the assessment sheet (bleeding, swelling, pain and physical impairment) and the results of radiological findings and physical examinations based on Haemophilia Joint Health Score 2.1 was assessed. An optimal scoring system was explored by the area under the curve (AUC). The cut-off value for the need for surgery or physiotherapy was determined using the receiver operating characteristic curve procedure. Forty-two patients were included. The 'physical impairment' item showed the highest correlation coefficient with the results of radiographic and physical examinations (range: 0.57-0.76). The AUC of finally adjusted scoring indicates good ability to discriminate between patients with and without a need for orthopaedic intervention. The positive predictive value was the highest at a cut-off value of 4 points for knees (63.0%) and ankles (70.0%), at 5 points for elbows (66.7%) and the highest predictive accuracy at the cut-off value of 4 points for all the joints. The linear trend of the need for an orthopaedic intervention was observed with an increasing score. The joint condition assessment sheet can help clinicians assess the need for orthopaedic intervention for haemophilic arthropathy in Japanese patients with haemophilia. © 2016 John Wiley & Sons Ltd.

  8. Highest Resolution Gaspra Mosaic

    Science.gov (United States)

    1992-01-01

    This picture of asteroid 951 Gaspra is a mosaic of two images taken by the Galileo spacecraft from a range of 5,300 kilometers (3,300 miles), some 10 minutes before closest approach on October 29, 1991. The Sun is shining from the right; phase angle is 50 degrees. The resolution, about 54 meters/pixel, is the highest for the Gaspra encounter and is about three times better than that in the view released in November 1991. Additional images of Gaspra remain stored on Galileo's tape recorder, awaiting playback in November. Gaspra is an irregular body with dimensions about 19 x 12 x 11 kilometers (12 x 7.5 x 7 miles). The portion illuminated in this view is about 18 kilometers (11 miles) from lower left to upper right. The north pole is located at upper left; Gaspra rotates counterclockwise every 7 hours. The large concavity on the lower right limb is about 6 kilometers (3.7 miles) across, the prominent crater on the terminator, center left, about 1.5 kilometers (1 mile). A striking feature of Gaspra's surface is the abundance of small craters. More than 600 craters, 100-500 meters (330-1650 feet) in diameter are visible here. The number of such small craters compared to larger ones is much greater for Gaspra than for previously studied bodies of comparable size such as the satellites of Mars. Gaspra's very irregular shape suggests that the asteroid was derived from a larger body by nearly catastrophic collisions. Consistent with such a history is the prominence of groove-like linear features, believed to be related to fractures. These linear depressions, 100-300 meters wide and tens of meters deep, are in two crossing groups with slightly different morphology, one group wider and more pitted than the other. Grooves had previously been seen only on Mars's moon Phobos, but were predicted for asteroids as well. Gaspra also shows a variety of enigmatic curved depressions and ridges in the terminator region at left. The Galileo project, whose primary mission is the

  9. Gaspra - Highest Resolution Mosaic

    Science.gov (United States)

    1992-01-01

    This picture of asteroid 951 Gaspra is a mosaic of two images taken by the Galileo spacecraft from a range of 5,300 kilometers (3,300 miles), some 10 minutes before closest approach on October 29, 1991. The Sun is shining from the right; phase angle is 50 degrees. The resolution, about 54 meters/pixel, is the highest for the Gaspra encounter and is about three times better than that in the view released in November 1991. Additional images of Gaspra remain stored on Galileo's tape recorder, awaiting playback in November. Gaspra is an irregular body with dimensions about 19 x 12 x 11 kilometers (12 x 7.5 x 7 miles). The portion illuminated in this view is about 18 kilometers (11 miles) from lower left to upper right. The north pole is located at upper left; Gaspra rotates counterclockwise every 7 hours. The large concavity on the lower right limb is about 6 kilometers (3.7 miles) across, the prominent crater on the terminator, center left, about 1.5 kilometers (1 mile). A striking feature of Gaspra's surface is the abundance of small craters. More than 600 craters, 100-500 meters (330-1650 feet) in diameter are visible here. The number of such small craters compared to larger ones is much greater for Gaspra than for previously studied bodies of comparable size such as the satellites of Mars. Gaspra's very irregular shape suggests that the asteroid was derived from a larger body by nearly catastrophic collisions. Consistent with such a history is the prominence of groove-like linear features, believed to be related to fractures. These linear depressions, 100-300 meters wide and tens of meters deep, are in two crossing groups with slightly different morphology, one group wider and more pitted than the other. Grooves had previously been seen only on Mars's moon Phobos, but were predicted for asteroids as well. Gaspra also shows a variety of enigmatic curved depressions and ridges in the terminator region at left. The Galileo project, whose primary mission is the

  10. Alpha-1-antitrypsin deficiency in Madeira (Portugal): the highest prevalence in the world.

    Science.gov (United States)

    Spínola, Carla; Bruges-Armas, Jácome; Pereira, Conceição; Brehm, António; Spínola, Hélder

    2009-10-01

    Alpha-1-antitrypsin (AAT) deficiency is a common genetic disease which affects both lung and liver. Early diagnosis can help asymptomatic patients to adjust their lifestyle choices in order to reduce the risk of Chronic Obstructive Pulmonary Disease (COPD). The determination of this genetic deficiency prevalence in Madeira Island (Portugal) population is important to clarify susceptibility and define the relevance of performing genetic tests for AAT on individuals at risk for COPD. Two hundred samples of unrelated individuals from Madeira Island were genotyped for the two most common AAT deficiency alleles, PI*S and PI*Z, using Polymerase Chain Reaction-Mediated Site-Directed Mutagenesis. Our results show one of the highest frequencies for both mutations when compared to any already studied population in the world. In fact, PI*S mutation has the highest prevalence (18%), and PI*Z mutation (2.5%) was the third highest worldwide. The frequency of AAT deficiency genotypes in Madeira (PI*ZZ, PI*SS, and PI*SZ) is estimated to be the highest in the world: 41 per 1000. This high prevalence of AAT deficiency on Madeira Island reveals an increased genetic susceptibility to COPD and suggests a routine genetic testing for individuals at risk.

  11. The combination of ovarian volume and outline has better diagnostic accuracy than prostate-specific antigen (PSA) concentrations in women with polycystic ovarian syndrome (PCOs).

    Science.gov (United States)

    Bili, Eleni; Bili, Authors Eleni; Dampala, Kaliopi; Iakovou, Ioannis; Tsolakidis, Dimitrios; Giannakou, Anastasia; Tarlatzis, Basil C

    2014-08-01

    The aim of this study was to determine the performance of prostate specific antigen (PSA) and ultrasound parameters, such as ovarian volume and outline, in the diagnosis of polycystic ovary syndrome (PCOS). This prospective, observational, case-controlled study included 43 women with PCOS, and 40 controls. Between day 3 and 5 of the menstrual cycle, fasting serum samples were collected and transvaginal ultrasound was performed. The diagnostic performance of each parameter [total PSA (tPSA), total-to-free PSA ratio (tPSA:fPSA), ovarian volume, ovarian outline] was estimated by means of receiver operating characteristic (ROC) analysis, along with area under the curve (AUC), threshold, sensitivity, specificity as well as positive (+) and negative (-) likelihood ratios (LRs). Multivariate logistical regression models, using ovarian volume and ovarian outline, were constructed. The tPSA and tPSA:fPSA ratio resulted in AUC of 0.74 and 0.70, respectively, with moderate specificity/sensitivity and insufficient LR+/- values. In the multivariate logistic regression model, the combination of ovarian volume and outline had a sensitivity of 97.7% and a specificity of 97.5% in the diagnosis of PCOS, with +LR and -LR values of 39.1 and 0.02, respectively. In women with PCOS, tPSA and tPSA:fPSA ratio have similar diagnostic performance. The use of a multivariate logistic regression model, incorporating ovarian volume and outline, offers very good diagnostic accuracy in distinguishing women with PCOS patients from controls. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  12. Influence of metallic dental implants and metal artefacts on dose calculation accuracy.

    Science.gov (United States)

    Maerz, Manuel; Koelbl, Oliver; Dobler, Barbara

    2015-03-01

    Metallic dental implants cause severe streaking artefacts in computed tomography (CT) data, which inhibit the correct representation of shape and density of the metal and the surrounding tissue. The aim of this study was to investigate the impact of dental implants on the accuracy of dose calculations in radiation therapy planning and the benefit of metal artefact reduction (MAR). A second aim was to determine the treatment technique which is less sensitive to the presence of metallic implants in terms of dose calculation accuracy. Phantoms consisting of homogeneous water equivalent material surrounding dental implants were designed. Artefact-containing CT data were corrected using the correct density information. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated on corrected and uncorrected CT data and compared to 2-dimensional dose measurements using GafChromic™ EBT2 films. For all plans the accuracy of dose calculations is significantly higher if performed on corrected CT data (p = 0.015). The agreement of calculated and measured dose distributions is significantly higher for VMAT than for IMRT plans for calculations on uncorrected CT data (p = 0.011) as well as on corrected CT data (p = 0.029). For IMRT and VMAT the application of metal artefact reduction significantly increases the agreement of dose calculations with film measurements. VMAT was found to provide the highest accuracy on corrected as well as on uncorrected CT data. VMAT is therefore preferable over IMRT for patients with metallic implants, if plan quality is comparable for the two techniques.

  13. Influence of metallic dental implants and metal artefacts on dose calculation accuracy

    International Nuclear Information System (INIS)

    Maerz, Manuel; Koelbl, Oliver; Dobler, Barbara

    2015-01-01

    Metallic dental implants cause severe streaking artefacts in computed tomography (CT) data, which inhibit the correct representation of shape and density of the metal and the surrounding tissue. The aim of this study was to investigate the impact of dental implants on the accuracy of dose calculations in radiation therapy planning and the benefit of metal artefact reduction (MAR). A second aim was to determine the treatment technique which is less sensitive to the presence of metallic implants in terms of dose calculation accuracy. Phantoms consisting of homogeneous water equivalent material surrounding dental implants were designed. Artefact-containing CT data were corrected using the correct density information. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated on corrected and uncorrected CT data and compared to 2-dimensional dose measurements using GafChromic trademark EBT2 films. For all plans the accuracy of dose calculations is significantly higher if performed on corrected CT data (p = 0.015). The agreement of calculated and measured dose distributions is significantly higher for VMAT than for IMRT plans for calculations on uncorrected CT data (p = 0.011) as well as on corrected CT data (p = 0.029). For IMRT and VMAT the application of metal artefact reduction significantly increases the agreement of dose calculations with film measurements. VMAT was found to provide the highest accuracy on corrected as well as on uncorrected CT data. VMAT is therefore preferable over IMRT for patients with metallic implants, if plan quality is comparable for the two techniques. (orig.) [de

  14. Directional clustering in highest energy cosmic rays

    International Nuclear Information System (INIS)

    Goldberg, Haim; Weiler, Thomas J.

    2001-01-01

    An unexpected degree of small-scale clustering is observed in highest-energy cosmic ray events. Some directional clustering can be expected due to purely statistical fluctuations for sources distributed randomly in the sky. This creates a background for events originating in clustered sources. We derive analytic formulas to estimate the probability of random cluster configurations, and use these formulas to study the strong potential of the HiRes, Auger, Telescope Array and EUSO-OWL-AirWatch facilities for deciding whether any observed clustering is most likely due to nonrandom sources. For a detailed comparison to data, our analytical approach cannot compete with Monte Carlo simulations, including experimental systematics. However, our derived formulas do offer two advantages: (i) easy assessment of the significance of any observed clustering, and most importantly, (ii) an explicit dependence of cluster probabilities on the chosen angular bin size

  15. Diagnostic Accuracy of Perioperative Measurement of Basal Anterior Pituitary and Target Gland Hormones in Predicting Adrenal Insufficiency After Pituitary Surgery.

    Science.gov (United States)

    Cerina, Vatroslav; Kruljac, Ivan; Radosevic, Jelena Marinkovic; Kirigin, Lora Stanka; Stipic, Darko; Pecina, Hrvoje Ivan; Vrkljan, Milan

    2016-03-01

    The insulin tolerance test (ITT) is the gold standard for diagnosing adrenal insufficiency (AI) after pituitary surgery. The ITT is unpleasant for patients, requires close medical supervision and is contraindicated in several comorbidities. The aim of this study was to analyze whether tumor size, remission rate, preoperative, and early postoperative baseline hormone concentrations could serve as predictors of AI in order to increase the diagnostic accuracy of morning serum cortisol. This prospective study enrolled 70 consecutive patients with newly diagnosed pituitary adenomas. Thirty-seven patients had nonfunctioning pituitary adenomas (NPA), 28 had prolactinomas and 5 had somatotropinomas. Thyroxin (T4), thyrotropin (TSH), prolactin, follicle-stimulating hormone (FSH), luteinizing hormone (LH), testosterone, and insulin-like growth factor 1 (IGF-I) were measured preoperatively and on the sixth postoperative day. Serum morning cortisol was measured on the third postoperative day (CORT3) as well as the sixth postoperative day (CORT6). Tumor mass was measured preoperatively and remission was assessed 3 months after surgery. An ITT was performed 3 to 6 months postoperatively. Remission was achieved in 48% of patients and AI occurred in 51%. Remission rates and tumor type were not associated with AI. CORT3 had the best predictive value for AI (area under the curve (AUC) 0.868, sensitivity 82.4%, specificity 83.3%). Tumor size, preoperative T4, postoperative T4, and TSH were also associated with AI in a multivariate regression model. A combination of all preoperative and postoperative variables (excluding serum cortisol) had a sensitivity of 75.0% and specificity of 77.8%. The predictive power of CORT3 substantially improved by adding those variables into the model (AUC 0.921, sensitivity 94.1%, specificity 78.3%, PPV 81.9%, NPV of 92.7%). In a subgroup analysis that included only female patients with NPA, LH had exactly the same predictive value as CORT3. The addition

  16. Association of Anthropometric Measurement Methods with Cardiovascular Disease Risk in Turkey

    Directory of Open Access Journals (Sweden)

    Kaan Sözmen

    2016-03-01

    Full Text Available Objective: The aim of this study is to compare the predic­tive power of anthropometric indices for risk of developing Coronary Heart Disease (CHD or CHD death. Methods: We used cross-sectional data from nationally representative Chronic Diseases and Risk Factors Sur­vey conducted by the Ministry of Health in 2011. Body mass index (BMI, waist circumference (WC, waist-to-hip ratio (WHR, waist to height ratio (WHtR, body adiposity index (BAI and A Body Shape Index (ABSI formed the anthropometric measures. For each participant risk of de­veloping CHD or dying from CVDs were calculated based on Framingham and SCORE risk equations. Predictive ability of anthropometric measurements was assessed by receiver operating characteristic (ROC curves. Results: Anthropometric measurements of central obe­sity recorded higher area under the ROC curve (AUC values than BMI in both men and women. While ABSI had the highest AUC values for Framingham 10-year pre­dicted risk (FRS for CHD death (AUC = 0.613, SCORE 10-year risk for CVD death (AUC = 0.633, in women AUC for ABSI was the highest for only SCORE risk threshold (AUC = 0.705. Among women, WHtR was found to be the best indicator for estimating CHD incidence (AUC = 0.706 and death from CVD (AUC = 0.696. Conclusion: Compared to traditional anthropometric measurements such as BMI, ABSI was a better indicator for given thresholds for estimating the risk of developing CHD and CVD death in men. Among women WHtR made better predictions for FRS thresholds, however, ABSI was better for predicting 10-year risk of CVD death calculated by SCORE risk equation.

  17. PREDICTION OF MALIGNANT BREAST LESIONS FROM MRI FEATURES: A COMPARISON OF ARTIFICIAL NEURAL NETWORK AND LOGISTIC REGRESSION TECHNIQUES

    Science.gov (United States)

    McLaren, Christine E.; Chen, Wen-Pin; Nie, Ke; Su, Min-Ying

    2009-01-01

    Rationale and Objectives Dynamic contrast enhanced MRI (DCE-MRI) is a clinical imaging modality for detection and diagnosis of breast lesions. Analytical methods were compared for diagnostic feature selection and performance of lesion classification to differentiate between malignant and benign lesions in patients. Materials and Methods The study included 43 malignant and 28 benign histologically-proven lesions. Eight morphological parameters, ten gray level co-occurrence matrices (GLCM) texture features, and fourteen Laws’ texture features were obtained using automated lesion segmentation and quantitative feature extraction. Artificial neural network (ANN) and logistic regression analysis were compared for selection of the best predictors of malignant lesions among the normalized features. Results Using ANN, the final four selected features were compactness, energy, homogeneity, and Law_LS, with area under the receiver operating characteristic curve (AUC) = 0.82, and accuracy = 0.76. The diagnostic performance of these 4-features computed on the basis of logistic regression yielded AUC = 0.80 (95% CI, 0.688 to 0.905), similar to that of ANN. The analysis also shows that the odds of a malignant lesion decreased by 48% (95% CI, 25% to 92%) for every increase of 1 SD in the Law_LS feature, adjusted for differences in compactness, energy, and homogeneity. Using logistic regression with z-score transformation, a model comprised of compactness, NRL entropy, and gray level sum average was selected, and it had the highest overall accuracy of 0.75 among all models, with AUC = 0.77 (95% CI, 0.660 to 0.880). When logistic modeling of transformations using the Box-Cox method was performed, the most parsimonious model with predictors, compactness and Law_LS, had an AUC of 0.79 (95% CI, 0.672 to 0.898). Conclusion The diagnostic performance of models selected by ANN and logistic regression was similar. The analytic methods were found to be roughly equivalent in terms of

  18. Exploring the cultural dimensions of the right to the highest ...

    African Journals Online (AJOL)

    The right to enjoying the highest attainable standard of health is incorporated in many international and regional human rights instruments. This right contains both freedoms and entitlements, including the freedom to control one's own health and body and the right to an accessible system of health care, goods and services.

  19. Accuracy of CNV Detection from GWAS Data.

    Directory of Open Access Journals (Sweden)

    Dandan Zhang

    2011-01-01

    Full Text Available Several computer programs are available for detecting copy number variants (CNVs using genome-wide SNP arrays. We evaluated the performance of four CNV detection software suites--Birdsuite, Partek, HelixTree, and PennCNV-Affy--in the identification of both rare and common CNVs. Each program's performance was assessed in two ways. The first was its recovery rate, i.e., its ability to call 893 CNVs previously identified in eight HapMap samples by paired-end sequencing of whole-genome fosmid clones, and 51,440 CNVs identified by array Comparative Genome Hybridization (aCGH followed by validation procedures, in 90 HapMap CEU samples. The second evaluation was program performance calling rare and common CNVs in the Bipolar Genome Study (BiGS data set (1001 bipolar cases and 1033 controls, all of European ancestry as measured by the Affymetrix SNP 6.0 array. Accuracy in calling rare CNVs was assessed by positive predictive value, based on the proportion of rare CNVs validated by quantitative real-time PCR (qPCR, while accuracy in calling common CNVs was assessed by false positive/false negative rates based on qPCR validation results from a subset of common CNVs. Birdsuite recovered the highest percentages of known HapMap CNVs containing >20 markers in two reference CNV datasets. The recovery rate increased with decreased CNV frequency. In the tested rare CNV data, Birdsuite and Partek had higher positive predictive values than the other software suites. In a test of three common CNVs in the BiGS dataset, Birdsuite's call was 98.8% consistent with qPCR quantification in one CNV region, but the other two regions showed an unacceptable degree of accuracy. We found relatively poor consistency between the two "gold standards," the sequence data of Kidd et al., and aCGH data of Conrad et al. Algorithms for calling CNVs especially common ones need substantial improvement, and a "gold standard" for detection of CNVs remains to be established.

  20. Collaboration between radiological technologists (radiographers) and junior doctors during image interpretation improves the accuracy of diagnostic decisions

    International Nuclear Information System (INIS)

    Kelly, B.S.; Rainford, L.A.; Gray, J.; McEntee, M.F.

    2012-01-01

    Rationale and Objectives: In Emergency Departments (ED) junior doctors regularly make diagnostic decisions based on radiographic images. This study investigates whether collaboration between junior doctors and radiographers impacts on diagnostic accuracy. Materials and Methods: Research was carried out in the ED of a university teaching hospital and included 10 pairs of participants. Radiographers and junior doctors were shown 42 wrist radiographs and 40 CT Brains and were asked for their level of confidence of the presence or absence of distal radius fractures or fresh intracranial bleeds respectively using ViewDEX software, first working alone and then in pairs. Receiver Operating Characteristic was used to analyze performance. Results were compared using one-way analysis of variance. Results: The results showed statistically significant improvements in the Area Under the Curve (AUC) of the junior doctors when working with the radiographers for both sets of images (wrist and CT) treated as random readers and cases (p ≤ 0.008 and p ≤ 0.0026 respectively). While the radiographers’ results saw no significant changes, their mean Az values did show an increasing trend when working in collaboration. Conclusion: Improvement in performance of junior doctors following collaboration strongly suggests changes in the potential to improve accuracy of patient diagnosis and therefore patient care. Further training for junior doctors in the interpretation of diagnostic images should also be considered. Decision making of junior doctors was positively impacted on after introducing the opinion of a radiographer. Collaboration exceeds the sum of the parts; the two professions are better together.

  1. Non-linear partial least square regression increases the estimation accuracy of grass nitrogen and phosphorus using in situ hyperspectral and environmental data

    CSIR Research Space (South Africa)

    Ramoelo, Abel

    2013-06-01

    Full Text Available in situ hyperspectral and environmental variables yielded the highest grass N and P estimation accuracy (R2 = 0.81, root mean square error (RMSE) = 0.08, and R2 = 0.80, RMSE = 0.03, respectively) as compared to using remote sensing variables only...

  2. Different diagnostic values of imaging parameters to predict pseudoprogression in glioblastoma subgroups stratified by MGMT promoter methylation

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ra Gyoung [Catholic Kwandong University International St. Mary' s Hospital, Department of Radiology, Catholic Kwandong University College of Medicine, Incheon (Korea, Republic of); Kim, Ho Sung; Shim, Woo Hyun; Kim, Sang Joon [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Paik, Wooyul [Dankook Unversity Hospital, Department of Radiology, Cheonan-si, Chungcheongnam-do (Korea, Republic of); Kim, Jeong Hoon [University of Ulsan College of Medicine, Asan Medical Center, Department of Neurosurgery, Seoul (Korea, Republic of)

    2017-01-15

    The aim of this study was to determine whether diffusion and perfusion imaging parameters demonstrate different diagnostic values for predicting pseudoprogression between glioblastoma subgroups stratified by O{sup 6}-mythylguanine-DNA methyltransferase (MGMT) promoter methylation status. We enrolled seventy-five glioblastoma patients that had presented with enlarged contrast-enhanced lesions on magnetic resonance imaging (MRI) one month after completing concurrent chemoradiotherapy and undergoing MGMT promoter methylation testing. The imaging parameters included 10 or 90 % histogram cutoffs of apparent diffusion coefficient (ADC10), normalized cerebral blood volume (nCBV90), and initial area under the time signal-intensity curve (IAUC90). The results of the areas under the receiver operating characteristic curve (AUCs) with cross-validation were compared between MGMT methylation and unmethylation groups. MR imaging parameters demonstrated a trend toward higher accuracy in the MGMT promoter methylation group than in the unmethylation group (cross-validated AUCs = 0.70-0.95 and 0.56-0.87, respectively). The combination of MGMT methylation status with imaging parameters improved the AUCs from 0.70 to 0.75-0.90 for both readers in comparison with MGMT methylation status alone. The probability of pseudoprogression was highest (95.7 %) when nCBV90 was below 4.02 in the MGMT promoter methylation group. MR imaging parameters could be stronger predictors of pseudoprogression in glioblastoma patients with the methylated MGMT promoter than in patients with the unmethylated MGMT promoter. (orig.)

  3. Diagnostic accuracy of quantitative 99mTc-MIBI scintimammography according to ROC curve analysis

    International Nuclear Information System (INIS)

    Kim, J. H.; Lee, H. K.; Seo, J. W.; Cho, N. S.; Cha, K. H.; Lee, T. H.

    1998-01-01

    99mTc-sestamibi scintimammography (SMM) has been shown to be a useful diagnostic test in the detection of breast cancer and the receiver operating characteristic (ROC) curve analysis provides detailed information of a diagnostic test. The purpose of this study was to evaluate the feasibility and efficacy of quantitative indices of SMM in the detection of malignant breast lesions according to ROC analysis. Prone anterior, lateral planar and supine SPECT imagings were performed on 75 female patients (mean age=43.4 yr) with breast mass (size≥0.8cm) after intravenous injection of 20-30 mCi 99mTc-sestamibi. 45 Malignant (Invasive ductal ca(36), Inv lobular ca(5), Inv duc + lob (1), Inv tubular ca (3)) and 30 benign (fibroadenoma (13), fib cyst(12), Fat necrosis(3), papilloma(1), paraffinoma (1)) lesions were histologically proven. Data were analyzed by creating three regions of interest (ROIs) over designated areas: lesion, normal breast and right chest wall. Lesion to normal (L/NL) and lesion to chest wall (L/CW) ratios were calculated for each patient both on the planar and SPECT. The area under the ROC curve (AUC) was calculated and compared among four semiquantitative indices and an average scintimammographic index (SMM(mean)) from arithmatic mean. ROC curve analysis revealed planar L/N, SPECT L/N and L/CW ratios provide comparable better diagnostic accuracies for detection of breast cancer than planar L/CW ratio (p<0.05), respectively. For quantitative SMM of 75 lesions, malignancy rate was 60%, and Sensitivity, Specificity, Positive Predictive Value, Negative Predictive Value and Accuracy were 0.78, 0.77, 0.84, 0.72 and 0.77, respectively. Quantitative SMM is an useful objective method for differentiating malignant from benign breast lesions

  4. Diagnostic accuracy of quantitative 99mTc-MIBI scintimammography according to ROC curve analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. H.; Lee, H. K.; Seo, J. W.; Cho, N. S.; Cha, K. H.; Lee, T. H. [Gachon Medical College, Gil Medical Center, Inchon (Korea, Republic of)

    1998-07-01

    99mTc-sestamibi scintimammography (SMM) has been shown to be a useful diagnostic test in the detection of breast cancer and the receiver operating characteristic (ROC) curve analysis provides detailed information of a diagnostic test. The purpose of this study was to evaluate the feasibility and efficacy of quantitative indices of SMM in the detection of malignant breast lesions according to ROC analysis. Prone anterior, lateral planar and supine SPECT imagings were performed on 75 female patients (mean age=43.4 yr) with breast mass (size{>=}0.8cm) after intravenous injection of 20-30 mCi 99mTc-sestamibi. 45 Malignant (Invasive ductal ca(36), Inv lobular ca(5), Inv duc + lob (1), Inv tubular ca (3)) and 30 benign (fibroadenoma (13), fib cyst(12), Fat necrosis(3), papilloma(1), paraffinoma (1)) lesions were histologically proven. Data were analyzed by creating three regions of interest (ROIs) over designated areas: lesion, normal breast and right chest wall. Lesion to normal (L/NL) and lesion to chest wall (L/CW) ratios were calculated for each patient both on the planar and SPECT. The area under the ROC curve (AUC) was calculated and compared among four semiquantitative indices and an average scintimammographic index (SMM(mean)) from arithmatic mean. ROC curve analysis revealed planar L/N, SPECT L/N and L/CW ratios provide comparable better diagnostic accuracies for detection of breast cancer than planar L/CW ratio (p<0.05), respectively. For quantitative SMM of 75 lesions, malignancy rate was 60%, and Sensitivity, Specificity, Positive Predictive Value, Negative Predictive Value and Accuracy were 0.78, 0.77, 0.84, 0.72 and 0.77, respectively. Quantitative SMM is an useful objective method for differentiating malignant from benign breast lesions.

  5. Intra- and inter-observer variability and accuracy in the determination of linear and angular measurements in computed tomography

    International Nuclear Information System (INIS)

    Christiansen, E.L.; Thompson, J.R.; Kopp, S.

    1986-01-01

    The observer variability and accuracy of linear and angular computed tomography (CT) software measurements in the transaxial plane were investigated for the temporomandibular joint with the General Electric 8800 CT/N Scanner. A dried and measured human mandible was embedded in plastic and scanned in vitro. Sixteen observers participated in the study. The following measurements were tested: inter- and extra-condylar distances, transverse condylar dimension, condylar angulation, and the plastic base of the specimen. Three frozen cadaveric heads were similarly scanned and measured in situ. Intra- and inter-observer variabilities were lowest for the specimen base and highest for condylar angulation. Neuroradiologists had the lowest variability as a group, and the radiology residents and paramedical personell had the highest, but the differences were small. No significant difference was found between CT and macroscopic measurement of the mandible. In situ measurement by CT of condyles with structural changes in the transaxial plane was, however, subject to substantial error. It was concluded that transaxial linear measurements of the condylar processes free of significant structural changes had an error and an accuracy well within acceptable limits. The error for angular measurements was significantly greater than the error for linear measurements

  6. Accuracy, precision, and economic efficiency for three methods of thrips (Thysanoptera: Thripidae) population density assessment.

    Science.gov (United States)

    Sutherland, Andrew M; Parrella, Michael P

    2011-08-01

    Western flower thrips, Frankliniella occidentalis (Pergande) (Thysanoptera: Thripidae), is a major horticultural pest and an important vector of plant viruses in many parts of the world. Methods for assessing thrips population density for pest management decision support are often inaccurate or imprecise due to thrips' positive thigmotaxis, small size, and naturally aggregated populations. Two established methods, flower tapping and an alcohol wash, were compared with a novel method, plant desiccation coupled with passive trapping, using accuracy, precision and economic efficiency as comparative variables. Observed accuracy was statistically similar and low (37.8-53.6%) for all three methods. Flower tapping was the least expensive method, in terms of person-hours, whereas the alcohol wash method was the most expensive. Precision, expressed by relative variation, depended on location within the greenhouse, location on greenhouse benches, and the sampling week, but it was generally highest for the flower tapping and desiccation methods. Economic efficiency, expressed by relative net precision, was highest for the flower tapping method and lowest for the alcohol wash method. Advantages and disadvantages are discussed for all three methods used. If relative density assessment methods such as these can all be assumed to accurately estimate a constant proportion of absolute density, then high precision becomes the methodological goal in terms of measuring insect population density, decision making for pest management, and pesticide efficacy assessments.

  7. Diagnostic accuracy of 201thallium-SPECT and 18F-FDG-PET in the clinical assessment of glioma recurrence

    International Nuclear Information System (INIS)

    Gomez-Rio, Manuel; Rodriguez-Fernandez, Antonio; Ramos-Font, Carlos; Lopez-Ramirez, Escarlata; Llamas-Elvira, Jose M.

    2008-01-01

    Reliable differential diagnosis between tumour recurrence and treatment-induced lesions is required to take advantage of new therapeutic approaches to recurrent gliomas. Structural imaging methods offer a high sensitivity but a low specificity, which might be improved by neurofunctional imaging. This study aimed to test the hypothesis that incorporation of 18-fluoro-deoxy-glucose positron emission tomography (FDG-PET) increases the accuracy of this differential diagnosis obtained with 201 Tl chloride-single-photon emission computed tomography ( 201 Tl-SPECT). Seventy-six patients (mean age 47.72 ± 16.19 years) under suspicion of glioma recurrence, 42% with low-grade and 58% with high-grade lesions, were studied by 201 Tl-SPECT and FDG-PET, reporting results under blinded conditions using visual analysis. Tumour was confirmed by histological confirmation (23 patients) or clinical and structural neuroimaging follow-up (mean of 2.6 years). This population had a high disease prevalence (72%). Globally, highest sensitivity was obtained using 201 Tl-SPECT assessed with MRI (96%) and highest specificity using FDG-PET + MRI (95%). FDG-PET appeared slightly better for confirming tumour recurrence, whereas 201 Tl-SPECT was superior for ruling out possible recurrence (disease present in 38% of FDG-PET negative explorations). In the high-grade subgroup, there were no false-positive examinations (specificity: 100%), but sensitivity differed among techniques ( 201 Tl-SPECT: 94%; 201 Tl-SPECT + MRI: 97%; FDG-PET + MRI: 83%). In the low-grade subgroup, 201 Tl-SPECT+ MRI showed highest sensitivity (95%) and lowest posttest negative probability (9%); FDG-PET + MRI offered highest specificity (92%) with a posttest negative probability of 35%. FDG-PET does not clearly improve the diagnostic accuracy of 201 Tl-SPECT, which appears to be a more appropriate examination for the diagnosis of possible brain tumour recurrence, especially for ruling it out. (orig.)

  8. The percentage of prostate-specific antigen (PSA) isoform [-2]proPSA and the Prostate Health Index improve the diagnostic accuracy for clinically relevant prostate cancer at initial and repeat biopsy compared with total PSA and percentage free PSA in men aged ≤65 years.

    Science.gov (United States)

    Boegemann, Martin; Stephan, Carsten; Cammann, Henning; Vincendeau, Sébastien; Houlgatte, Alain; Jung, Klaus; Blanchet, Jean-Sebastien; Semjonow, Axel

    2016-01-01

    To prospectively test the diagnostic accuracy of the percentage of prostate specific antigen (PSA) isoform [-2]proPSA (%p2PSA) and the Prostate Health Index (PHI), and to determine their role for discrimination between significant and insignificant prostate cancer at initial and repeat prostate biopsy in men aged ≤65 years. The diagnostic performance of %p2PSA and PHI were evaluated in a multicentre study. In all, 769 men aged ≤65 years scheduled for initial or repeat prostate biopsy were recruited in four sites based on a total PSA (t-PSA) level of 1.6-8.0 ng/mL World Health Organization (WHO) calibrated (2-10 ng/mL Hybritech-calibrated). Serum samples were measured for the concentration of t-PSA, free PSA (f-PSA) and p2PSA with Beckman Coulter immunoassays on Access-2 or DxI800 instruments. PHI was calculated as (p2PSA/f-PSA × √t-PSA). Uni- and multivariable logistic regression models and an artificial neural network (ANN) were complemented by decision curve analysis (DCA). In univariate analysis %p2PSA and PHI were the best predictors of prostate cancer detection in all patients (area under the curve [AUC] 0.72 and 0.73, respectively), at initial (AUC 0.67 and 0.69) and repeat biopsy (AUC 0.74 and 0.74). t-PSA and %f-PSA performed less accurately for all patients (AUC 0.54 and 0.62). For detection of significant prostate cancer (based on Prostate Cancer Research International Active Surveillance [PRIAS] criteria) the %p2PSA and PHI equally demonstrated best performance (AUC 0.70 and 0.73) compared with t-PSA and %f-PSA (AUC 0.54 and 0.59). In multivariate analysis PHI we added to a base model of age, prostate volume, digital rectal examination, t-PSA and %f-PSA. PHI was strongest in predicting prostate cancer in all patients, at initial and repeat biopsy and for significant prostate cancer (AUC 0.73, 0.68, 0.78 and 0.72, respectively). In DCA for all patients the ANN showed the broadest threshold probability and best net benefit. PHI as single parameter

  9. Ranking factors involved in diabetes remission after bariatric surgery using machine-learning integrating clinical and genomic biomarkers

    DEFF Research Database (Denmark)

    Pedersen, Helle Krogh; Gudmundsdottir, Valborg; Pedersen, Mette Krogh

    2016-01-01

    , use of insulin-sensitising agents and baseline serum insulin levels, as the most informative variables with a decent internal validation performance (74% accuracy, area under the curve (AUC) 0.81). Adding information for the eight top-ranked single nucleotide polymorphisms (SNPs) significantly boosted...... classification performance to 84% accuracy (AUC 0.92). The eight SNPs mapped to eight genes — ABCA1, ARHGEF12, CTNNBL1, GLI3, PROK2, RYBP, SMUG1 and STXBP5 — three of which are known to have a role in insulin secretion, insulin sensitivity or obesity, but have not been indicated for diabetes remission after...

  10. Meditation experience predicts introspective accuracy.

    Directory of Open Access Journals (Sweden)

    Kieran C R Fox

    Full Text Available The accuracy of subjective reports, especially those involving introspection of one's own internal processes, remains unclear, and research has demonstrated large individual differences in introspective accuracy. It has been hypothesized that introspective accuracy may be heightened in persons who engage in meditation practices, due to the highly introspective nature of such practices. We undertook a preliminary exploration of this hypothesis, examining introspective accuracy in a cross-section of meditation practitioners (1-15,000 hrs experience. Introspective accuracy was assessed by comparing subjective reports of tactile sensitivity for each of 20 body regions during a 'body-scanning' meditation with averaged, objective measures of tactile sensitivity (mean size of body representation area in primary somatosensory cortex; two-point discrimination threshold as reported in prior research. Expert meditators showed significantly better introspective accuracy than novices; overall meditation experience also significantly predicted individual introspective accuracy. These results suggest that long-term meditators provide more accurate introspective reports than novices.

  11. A Highest Order Hypothesis Compatibility Test for Monocular SLAM

    OpenAIRE

    Edmundo Guerra; Rodrigo Munguia; Yolanda Bolea; Antoni Grau

    2013-01-01

    Simultaneous Location and Mapping (SLAM) is a key problem to solve in order to build truly autonomous mobile robots. SLAM with a unique camera, or monocular SLAM, is probably one of the most complex SLAM variants, based entirely on a bearing-only sensor working over six DOF. The monocular SLAM method developed in this work is based on the Delayed Inverse-Depth (DI-D) Feature Initialization, with the contribution of a new data association batch validation technique, the Highest Order Hyp...

  12. An Automated Micro-Total Immunoassay System for Measuring Cancer-Associated α2,3-linked Sialyl N-Glycan-Carrying Prostate-Specific Antigen May Improve the Accuracy of Prostate Cancer Diagnosis

    Directory of Open Access Journals (Sweden)

    Tomokazu Ishikawa

    2017-02-01

    Full Text Available The low specificity of the prostate-specific antigen (PSA for early detection of prostate cancer (PCa is a major issue worldwide. The aim of this study to examine whether the serum PCa-associated α2,3-linked sialyl N-glycan-carrying PSA (S2,3PSA ratio measured by automated micro-total immunoassay systems (μTAS system can be applied as a diagnostic marker of PCa. The μTAS system can utilize affinity-based separation involving noncovalent interaction between the immunocomplex of S2,3PSA and Maackia amurensis lectin to simultaneously determine concentrations of free PSA and S2,3PSA. To validate quantitative performance, both recombinant S2,3PSA and benign-associated α2,6-linked sialyl N-glycan-carrying PSA (S2,6PSA purified from culture supernatant of PSA cDNA transiently-transfected Chinese hamster ovary (CHO-K1 cells were used as standard protein. Between 2007 and 2016, fifty patients with biopsy-proven PCa were pair-matched for age and PSA levels, with the same number of benign prostatic hyperplasia (BPH patients used to validate the diagnostic performance of serum S2,3PSA ratio. A recombinant S2,3PSA- and S2,6PSA-spiked sample was clearly discriminated by μTAS system. Limit of detection of S2,3PSA was 0.05 ng/mL and coefficient variation was less than 3.1%. The area under the curve (AUC for detection of PCa for the S2,3PSA ratio (%S2,3PSA with cutoff value 43.85% (AUC; 0.8340 was much superior to total PSA (AUC; 0.5062 using validation sample set. Although the present results are preliminary, the newly developed μTAS platform for measuring %S2,3PSA can achieve the required assay performance specifications for use in the practical and clinical setting and may improve the accuracy of PCa diagnosis. Additional validation studies are warranted.

  13. Overlay accuracy fundamentals

    Science.gov (United States)

    Kandel, Daniel; Levinski, Vladimir; Sapiens, Noam; Cohen, Guy; Amit, Eran; Klein, Dana; Vakshtein, Irina

    2012-03-01

    Currently, the performance of overlay metrology is evaluated mainly based on random error contributions such as precision and TIS variability. With the expected shrinkage of the overlay metrology budget to DBO (1st order diffraction based overlay). It is demonstrated that the sensitivity of DBO to overlay mark asymmetry is larger than the sensitivity of imaging overlay. Finally, we show that a recently developed measurement quality metric serves as a valuable tool for improving overlay metrology accuracy. Simulation results demonstrate that the accuracy of imaging overlay can be improved significantly by recipe setup optimized using the quality metric. We conclude that imaging overlay metrology, complemented by appropriate use of measurement quality metric, results in optimal overlay accuracy.

  14. Prediction of renal function (GFR) from cystatin C and creatinine in children: Body cell mass increases accuracy of the estimate

    DEFF Research Database (Denmark)

    Andersen, Trine Borup; Jødal, Lars; Bøgsted, Martin

    ) aged 2-14 years (mean 8.8 years). GFR was 14-147 mL/min/1.73m2 (mean 97 mL/min/1.73m2). BCM was estimated using bioimpedance spectroscopy (Xitron Hydra 4200). Log-transformed data on BCM/CysC, serum creatinine (SCr), body-surface-area (BSA), height x BSA/SCr, serum CysC, weight, sex, age, height, serum....... The present equation also had the highest R2 and the narrowest 95% limits of agreement. CONCLUSION: The new equation predicts GFR with higher accuracy than other equations. Endogenous methods are, however, still not accurate enough to replace exogenous markers when GFR must be determined with high accuracy...

  15. Accuracy of the third molar maturity index in assessing the legal age of 18 years: a systematic review and meta-analysis.

    Science.gov (United States)

    Santiago, Bianca Marques; Almeida, Leopoldina; Cavalcanti, Yuri Wanderley; Magno, Marcela Baraúna; Maia, Lucianne Cople

    2017-12-22

    The age estimation is a complex procedure required in the daily practice of legal medicine. The maturity of third molars stands out by the age of 18 because these teeth are still in development. This systematic review aimed to assess the accuracy of the third molar maturity index (I 3M ), proposed by Cameriere et al. (2008), in discriminating whether an individual is under or over 18 years. Seven electronic databases were screened: PubMed, Scopus, ISI Web of Science, Cochrane Library, LILACS, SIGLE, and CAPES. Eligible studies included an assessment of I 3M accuracy at the 0.08 cut-off value. The quality assessment was performed by using QUADAS 2. Three meta-analyses (MA) were accomplished: overall, one for males and another for females. From 2397 articles identified, 16 met the eligibility criteria. Of these, two showed high risk of bias, one in the reference standard domain and the other in the flow and timing domain. The percentage of individuals correctly classified ranged from 72.4 to 96.0%. The overall MA showed pooled sensitivity of 0.86 (0.84 to 0.87; p = 0.0000) and pooled specificity of 0.93 (0.92 to 0.94; p = 0.0000). The AUC (area under the summary receiver operator characteristics curve) and DOR (diagnostic odds ratio) values were, respectively, 0.9652 and 104.68, indicating an overall high discrimination effect. Separately, better results of accuracy were found for males. High heterogeneity was achieved for both sensibility (94.6%) and specificity (88.8%). We conclude that the I 3M is a suitable and useful method for estimating adulthood regarding forensic purposes, regardless of gender.

  16. Accuracy and cut-off values of pepsinogens I, II and gastrin 17 for diagnosis of gastric fundic atrophy: influence of gastritis.

    Directory of Open Access Journals (Sweden)

    Dariush Nasrollahzadeh

    Full Text Available BACKGROUND: To establish optimal cutoff values for serologic diagnosis of fundic atrophy in a high-risk area for oesophageal squamous cell carcinoma and gastric cancer with high prevalence of Helicobacter pylori (H. pylori in Northern Iran, we performed an endoscopy-room-based validation study. METHODS: We measured serum pepsinogens I (PGI and II (PGII, gastrin 17 (G-17, and antibodies against whole H. pylori, or cytotoxin-associated gene A (CagA antigen among 309 consecutive patients in two major endoscopy clinics in northeastern Iran. Updated Sydney System was used as histology gold standard. Areas under curves (AUCs, optimal cutoff and predictive values were calculated for serum biomarkers against the histology. RESULTS: 309 persons were recruited (mean age: 63.5 years old, 59.5% female. 84.5% were H. pylori positive and 77.5% were CagA positive. 21 fundic atrophy and 101 nonatrophic pangastritis were diagnosed. The best cutoff values in fundic atrophy assessment were calculated at PGI40 pmol/l was 81% sensitive and 73.3% specific for diagnosing fundic atrophy. At cutoff concentration of 11.8 µg/l, PGII showed 84.2% sensitivity and 45.4% specificity to distinguish nonatrophic pangastritis. Exclusion of nonatrophic pangastritis enhanced diagnostic ability of PGI/PGII ratio (from AUC = 0.66 to 0.90 but did not affect AUC of PGI. After restricting study samples to those with PGII<11.8, the sensitivity of using PGI<56 to define fundic atrophy increased to 83.3% (95%CI 51.6-97.9 and its specificity decreased to 88.8% (95%CI 80.8-94.3. CONCLUSIONS: Among endoscopy clinic patients, PGII is a sensitive marker for extension of nonatrophic gastritis toward the corpus. PGI is a stable biomarker in assessment of fundic atrophy and has similar accuracy to PGI/PGII ratio among populations with prevalent nonatrophic pangastritis.

  17. Diagnostic accuracy of soluble urokinase plasminogen activator receptor (suPAR) for prediction of bacteremia in patients with systemic inflammatory response syndrome.

    Science.gov (United States)

    Hoenigl, Martin; Raggam, Reinhard B; Wagner, Jasmin; Valentin, Thomas; Leitner, Eva; Seeber, Katharina; Zollner-Schwetz, Ines; Krammer, Werner; Prüller, Florian; Grisold, Andrea J; Krause, Robert

    2013-02-01

    Soluble urokinase plasminogen activator receptor (suPAR) serum concentrations have recently been described to reflect the severity status of systemic inflammation. In this study, the diagnostic accuracy of suPAR, C-reactive protein (CRP), procalcitonin (PCT), and interleukin-6 (IL-6) to predict bacteremia in patients with systemic inflammatory response syndrome (SIRS) was compared. A total of 132 patients with SIRS were included. In 55 patients blood cultures had resulted positive (study group 1, Gram positive bacteria: Staphylococcus aureus and Streptococcus spp., n=15; study group 2, Gram-negative bacteria, n=40) and 77 patients had negative blood culture results (control group, n=77). Simultaneously with blood cultures suPAR, CRP, PCT, IL-6 and white blood count (WBC) were determined. SuPAR values were significantly higher in study group 1 (median 8.11; IQR 5.78-15.53; p=0.006) and study group 2 (median 9.62; IQR 6.52-11.74; p<0.001) when compared with the control group (median 5.65; IQR 4.30-7.83). ROC curve analysis revealed an AUC of 0.726 for suPAR in differentiating SIRS patients with bacteremia from those without. The biomarkers PCT and IL-6 showed comparable results. Regarding combinations of biomarkers multiplying suPAR, PCT and IL-6 was most promising and resulted in an AUC value of 0.804. Initial suPAR serum concentrations were significantly higher (p=0.028) in patients who died within 28 days than in those who survived. No significant difference was seen for PCT, IL-6 and CRP. In conclusion, suPAR, IL-6 and PCT may contribute to predicting bacteremia in SIRS patients. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Geocoding accuracy and the recovery of relationships between environmental exposures and health

    Directory of Open Access Journals (Sweden)

    Zimmerman Dale L

    2008-04-01

    Full Text Available Abstract Background This research develops methods for determining the effect of geocoding quality on relationships between environmental exposures and health. The likelihood of detecting an existing relationship – statistical power – between measures of environmental exposures and health depends not only on the strength of the relationship but also on the level of positional accuracy and completeness of the geocodes from which the measures of environmental exposure are made. This paper summarizes the results of simulation studies conducted to examine the impact of inaccuracies of geocoded addresses generated by three types of geocoding processes: a addresses located on orthophoto maps, b addresses matched to TIGER files (U.S Census or their derivative street files; and, c addresses from E-911 geocodes (developed by local authorities for emergency dispatch purposes. Results The simulated odds of disease using exposures modelled from the highest quality geocodes could be sufficiently recovered using other, more commonly used, geocoding processes such as TIGER and E-911; however, the strength of the odds relationship between disease exposures modelled at geocodes generally declined with decreasing geocoding accuracy. Conclusion Although these specific results cannot be generalized to new situations, the methods used to determine the sensitivity of results can be used in new situations. Estimated measures of positional accuracy must be used in the interpretation of results of analyses that investigate relationships between health outcomes and exposures measured at residential locations. Analyses similar to those employed in this paper can be used to validate interpretation of results from empirical analyses that use geocoded locations with estimated measures of positional accuracy.

  19. Lesion type and reader experience affect the diagnostic accuracy of breast MRI: A multiple reader ROC study

    Energy Technology Data Exchange (ETDEWEB)

    Baltzer, Pascal A.T., E-mail: patbaltzer@gmail.com [Department of Biomedical Imaging and Imge-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna (Austria); Kaiser, Werner Alois [Department of Diagnostic and Interventional Radiology, University Hospital Jena, Erlanger Allee 101, 07740 Jena (Germany); Dietzel, Matthias, E-mail: dietzelmatthias2@hotmail.com [Department of Neuroradiology, University Hospital Erlangen, Schwabachanlage 6, 91054 Erlangen (Germany)

    2015-01-15

    Highlights: • The main findings of our study are, that reader experience and lesion type (i.e., mass versus non-mass enhancement) are independent predictors of the diagnostic accuracy of breast MRI. • Specifically, benign and malignant non-mass lesions cannot be differentiated with sufficient accuracy, especially if readers are not experienced. • We conclude that future research in breast MRI should focus on non-mass lesions, as these are the problem makers in modern breast MRI. - Abstract: Purpose: To evaluate the influence of lesion type (mass versus non-mass) and reader experience on the diagnostic performance of breast MRI (BMRI) in a non-screening setting. Materials and methods: Consecutive patients (mean age, 55 ± 12 years) with breast lesions that were verified by biopsy or surgery, and who had had BMRI as part of their diagnostic workup, were eligible for this retrospective single-center study. Cancers diagnosed by biopsy before BMRI were excluded to eliminate biological and interpretation bias due to biopsy or chemotherapy effects (n = 103). Six blinded readers (experience level, high (HE, n = 2); intermediate (IE, n = 2); and low (LE, n = 2)) evaluated all examinations and assigned independent MRI BI-RADS ratings. Lesion type (mass, non-mass, focal) was noted. Receiver operating characteristics (ROC) and logistic regression analysis was performed to compare diagnostic accuracies. Results: There were 259 histologically verified lesions (123 malignant, 136 benign) investigated. There were 169 mass (103 malignant, 66 benign) and 48 non-mass lesions (19 malignant, 29 benign). Another 42 lesions that met the inclusion criteria were biopsied due to conventional findings (i.e., microcalcifications, architectural distortions), but did not enhance on MRI (41 benign, one DCIS). ROC analysis revealed a total area under the curve (AUC) between 0.834 (LE) and 0.935 (HI). Logistic regression identified a significant effect of non-mass lesions (P < 0.0001) and

  20. Requisite accuracy for hot spot factors in fast reactors

    International Nuclear Information System (INIS)

    Miki, Kazuyoshi; Inoue, Kotaro

    1976-01-01

    In the thermal design of a fast reactor, it should be most effective to reduce hot spot factors to the lowest possible level compatible with safety considerations, in order to minimize the design margin for the temperature prevailing in the core. Hot spot factors account for probabilistic and statistic deviations from nominal value of fuel element temperatures, due to uncertainties in the data adopted for estimating various factors including the physical properties. Such temperature deviations necessitate the provision of correspondingly large design margins for temperatures in order to keep within permissible limits the probability of exceeding the allowable temperatures. Evaluation of the desired accuracy for hot spot factors is performed by a method of optimization, which permits determination of the degree of accuracy that should minimize the design margins, to give realistic results with consideration given not only to sensitivity coefficients but also to the present-day uncertainty levels in the data adopted in the calculations. A concept of ''degree of difficulty'' is introduced for the purpose of determining the hot spot factors to be given higher priority for reduction. Application of this method to the core of a prototype fast reactor leads to the conclusion that the hot spot factors to be given the highest priority are those relevant to the power distribution, the flow distribution, the fuel enrichment, the fuel-cladding gap conductance and the fuel thermal conductivity. (auth.)

  1. Comparative analysis of Worldview-2 and Landsat 8 for coastal saltmarsh mapping accuracy assessment

    Science.gov (United States)

    Rasel, Sikdar M. M.; Chang, Hsing-Chung; Diti, Israt Jahan; Ralph, Tim; Saintilan, Neil

    2016-05-01

    Coastal saltmarsh and their constituent components and processes are of an interest scientifically due to their ecological function and services. However, heterogeneity and seasonal dynamic of the coastal wetland system makes it challenging to map saltmarshes with remotely sensed data. This study selected four important saltmarsh species Pragmitis australis, Sporobolus virginicus, Ficiona nodosa and Schoeloplectus sp. as well as a Mangrove and Pine tree species, Avecinia and Casuarina sp respectively. High Spatial Resolution Worldview-2 data and Coarse Spatial resolution Landsat 8 imagery were selected in this study. Among the selected vegetation types some patches ware fragmented and close to the spatial resolution of Worldview-2 data while and some patch were larger than the 30 meter resolution of Landsat 8 data. This study aims to test the effectiveness of different classifier for the imagery with various spatial and spectral resolutions. Three different classification algorithm, Maximum Likelihood Classifier (MLC), Support Vector Machine (SVM) and Artificial Neural Network (ANN) were tested and compared with their mapping accuracy of the results derived from both satellite imagery. For Worldview-2 data SVM was giving the higher overall accuracy (92.12%, kappa =0.90) followed by ANN (90.82%, Kappa 0.89) and MLC (90.55%, kappa = 0.88). For Landsat 8 data, MLC (82.04%) showed the highest classification accuracy comparing to SVM (77.31%) and ANN (75.23%). The producer accuracy of the classification results were also presented in the paper.

  2. Diagnostic accuracy for apical and chronic periodontitis biomarkers in gingival crevicular fluid: an exploratory study.

    Science.gov (United States)

    Baeza, Mauricio; Garrido, Mauricio; Hernández-Ríos, Patricia; Dezerega, Andrea; García-Sesnich, Jocelyn; Strauss, Franz; Aitken, Juan Pablo; Lesaffre, Emmanuel; Vanbelle, Sophie; Gamonal, Jorge; Brignardello-Petersen, Romina; Tervahartiala, Taina; Sorsa, Timo; Hernández, Marcela

    2016-01-01

    The aim of this study was to assess the levels and diagnostic accuracy of a set of potential biomarkers of periodontal tissue metabolism in gingival crevicular fluid (GCF) from patients with chronic periodontitis (CP) and asymptomatic apical periodontitis ( AAP). Thirty one GCF samples from 11 CP patients, 44 GCF samples from 38 AAP patients and 31 GCF samples from 13 healthy volunteers were obtained (N = 106). Matrix metalloproteinases (MMPs) -2 and -9 were determined by zymography; levels of MMP-8 by ELISA and IFMA and MPO by ELISA. IL-1, IL-6, TNFα, DKK-1, Osteonectin, Periostin, TRAP-5 and OPG were determined by a multiplex quantitative panel. Statistical analysis was performed using linear mixed-effects models. The MMP-9 and MMP-8 were higher in CP, followed by AAP, versus healthy individuals (p 0.97) in CP, and for the active form of MMP-9 and MMP-8 (AUC > 0.90) in AAP. Gingival crevicular fluid composition is modified by CP and AAP. MMP-9 and MMP-8 show diagnostic potential for CP and AAP, whereas MMP-2 and TRAP-5 are useful only for CP. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Diagnostic accuracy and recall rates for digital mammography and digital mammography combined with one-view and two-view tomosynthesis: results of an enriched reader study.

    Science.gov (United States)

    Rafferty, Elizabeth A; Park, Jeong Mi; Philpotts, Liane E; Poplack, Steven P; Sumkin, Jules H; Halpern, Elkan F; Niklason, Loren T

    2014-02-01

    The purpose of this study was to compare two methods of combining tomosynthesis with digital mammography by assessing diagnostic accuracy and recall rates for digital mammography alone and digital mammography combined with one-view tomosynthesis and two-view tomosynthesis. Three hundred ten cases including biopsy-proven malignancies (51), biopsy-proven benign findings (47), recalled screening cases (138), and negative screening cases (74) were reviewed by 15 radiologists sequentially using digital mammography, adding one-view tomosynthesis, and then two-view tomosynthesis. Cases were assessed for recall and assigned a BI-RADS score and probability of malignancy for each imaging method. Diagnostic accuracy was assessed using receiver operating characteristic (ROC) analysis. Screening recall rates were compared using pooled logistical regression analysis. A p value of tomosynthesis, and DM plus two-view tomosynthesis was 0.828, 0.864, and 0.895, respectively. Both one-view and two-view tomosynthesis plus DM were significantly better than DM alone (Δ AUCs 0.036 [p = 0.009] and 0.068 [p tomosynthesis, and DM plus two-view tomosynthesis were 44.2%, 27.2%, and 24.0%, respectively. Combined with DM, one-view and two-view tomosynthesis both showed significantly lower noncancer recall rates than digital mammography alone (p tomosynthesis showed a significantly lower recall rate than digital mammography with one-view tomosynthesis (p tomosynthesis compared with digital mammography alone. Compared with digital mammography, diagnostic sensitivity for invasive cancers increased with the addition of both one-view (Δ12.0%, p tomosynthesis. The addition of one-view tomosynthesis to conventional digital mammography improved diagnostic accuracy and reduced the recall rate; however, the addition of two-view tomosynthesis provided twice the performance gain in diagnostic accuracy while further reducing the recall rate.

  4. Incremental value of 99mTc-HYNIC-TOC SPECT/CT over whole-body planar scintigraphy and SPECT in patients with neuroendocrine tumours.

    Science.gov (United States)

    Trogrlic, Mate; Težak, Stanko

    2017-06-12

    The aim of this study was to evaluate the additional value of 99m Tc-HYNIC-TOC SPECT/CT over planar whole-body (WB) scintigraphy and SPECT alone in the detection and accurate localisation of neuroendocrine tumour (NET) lesions. This study included 65 patients with a definitive histological diagnosis of NET prior to scintigraphy. Planar WB scintigraphy, SPECT, and SPECT/CT images were acquired at 4 h post-administration of 670 MBq 99m Tc-HYNIC-TOC. Additional SPECT images at 10 min after tracer administration were also acquired. Clinical and imaging follow-up findings were considered as the reference standards (minimum follow-up period, 15 months). Patient and lesion-based analyses of the efficacies of the imaging modalities were performed. While 38 patients exhibited metastasis of NETs, 27 presented no evidence of metastasis. Upon patient-based analysis, the sensitivity and specificity of SPECT/CT were found to be 88.9 and 79.3 %, respectively. The diagnostic accuracies of WB scintigraphy, 4h-SPECT, and SPECT/CT were 72.3, 73.8, and 84.6 %, respectively. The area under curve (AUC) value for SPECT/CT (0.84) was the highest, followed by those for 4h-SPECT (0.75) and WB scintigraphy (0.74). The accuracy and AUC values of SPECT/CT were significantly better compared to those of WB scintigraphy (p < 0.001), 10 min-SPECT (p < 0.001), and 4 h-SPECT (p = 0.001). The findings of SPECT/CT led to the change in treatment plan of 11 patients (16.9 %). The sensitivity and diagnostic accuracy of SPECT/CT in the evaluation of NET lesions outperforms planar WB imaging or SPECT alone.

  5. Relationship between functional imaging and immunohistochemical markers and prediction of breast cancer subtype: a PET/MRI study.

    Science.gov (United States)

    Incoronato, Mariarosaria; Grimaldi, Anna Maria; Cavaliere, Carlo; Inglese, Marianna; Mirabelli, Peppino; Monti, Serena; Ferbo, Umberto; Nicolai, Emanuele; Soricelli, Andrea; Catalano, Onofrio Antonio; Aiello, Marco; Salvatore, Marco

    2018-04-25

    SUL values were associated with the luminal A subtype. Kep max was able to discriminate between luminal A and luminal B subtypes (AUC = 0.779), and its highest values were associated with the luminal B subtype. Ktrans max (AUC = 0.881) was able to discriminate between luminal A and nonluminal subtypes, and the highest perfusion values were associated with the nonluminal subtype. In addition, ADC (AUC = 0.877) was able to discriminate between luminal B and nonluminal subtypes, and the lowest ADC mean values were associated with the luminal B subtype. Multivariate analysis was performed to develop a prognostic model, and the best predictive model included Ktrans max and SUV max parameters. Using multivariate analysis of both PET and MRI parameters, a prognostic model including Ktrans max and SUV max was able to predict the tumour subtype in 38 of 49 patients (77.6%, p < 0.001), with higher accuracy for the luminal B subtype (86.2%).

  6. Comparing the accuracy of perturbative and variational calculations for predicting fundamental vibrational frequencies of dihalomethanes

    Science.gov (United States)

    Krasnoshchekov, Sergey V.; Schutski, Roman S.; Craig, Norman C.; Sibaev, Marat; Crittenden, Deborah L.

    2018-02-01

    Three dihalogenated methane derivatives (CH2F2, CH2FCl, and CH2Cl2) were used as model systems to compare and assess the accuracy of two different approaches for predicting observed fundamental frequencies: canonical operator Van Vleck vibrational perturbation theory (CVPT) and vibrational configuration interaction (VCI). For convenience and consistency, both methods employ the Watson Hamiltonian in rectilinear normal coordinates, expanding the potential energy surface (PES) as a Taylor series about equilibrium and constructing the wavefunction from a harmonic oscillator product basis. At the highest levels of theory considered here, fourth-order CVPT and VCI in a harmonic oscillator basis with up to 10 quanta of vibrational excitation in conjunction with a 4-mode representation sextic force field (SFF-4MR) computed at MP2/cc-pVTZ with replacement CCSD(T)/aug-cc-pVQZ harmonic force constants, the agreement between computed fundamentals is closer to 0.3 cm-1 on average, with a maximum difference of 1.7 cm-1. The major remaining accuracy-limiting factors are the accuracy of the underlying electronic structure model, followed by the incompleteness of the PES expansion. Nonetheless, computed and experimental fundamentals agree to within 5 cm-1, with an average difference of 2 cm-1, confirming the utility and accuracy of both theoretical models. One exception to this rule is the formally IR-inactive but weakly allowed through Coriolis-coupling H-C-H out-of-plane twisting mode of dichloromethane, whose spectrum we therefore revisit and reassign. We also investigate convergence with respect to order of CVPT, VCI excitation level, and order of PES expansion, concluding that premature truncation substantially decreases accuracy, although VCI(6)/SFF-4MR results are still of acceptable accuracy, and some error cancellation is observed with CVPT2 using a quartic force field.

  7. Accuracy of genomic selection for alfalfa biomass yield in different reference populations.

    Science.gov (United States)

    Annicchiarico, Paolo; Nazzicari, Nelson; Li, Xuehui; Wei, Yanling; Pecetti, Luciano; Brummer, E Charles

    2015-12-01

    Genomic selection based on genotyping-by-sequencing (GBS) data could accelerate alfalfa yield gains, if it displayed moderate ability to predict parent breeding values. Its interest would be enhanced by predicting ability also for germplasm/reference populations other than those for which it was defined. Predicting accuracy may be influenced by statistical models, SNP calling procedures and missing data imputation strategies. Landrace and variety material from two genetically-contrasting reference populations, i.e., 124 elite genotypes adapted to the Po Valley (sub-continental climate; PV population) and 154 genotypes adapted to Mediterranean-climate environments (Me population), were genotyped by GBS and phenotyped in separate environments for dry matter yield of their dense-planted half-sib progenies. Both populations showed no sub-population genetic structure. Predictive accuracy was higher by joint rather than separate SNP calling for the two data sets, and using random forest imputation of missing data. Highest accuracy was obtained using Support Vector Regression (SVR) for PV, and Ridge Regression BLUP and SVR for Me germplasm. Bayesian methods (Bayes A, Bayes B and Bayesian Lasso) tended to be less accurate. Random Forest Regression was the least accurate model. Accuracy attained about 0.35 for Me in the range of 0.30-0.50 missing data, and 0.32 for PV at 0.50 missing data, using at least 10,000 SNP markers. Cross-population predictions based on a smaller subset of common SNPs implied a relative loss of accuracy of about 25% for Me and 30% for PV. Genome-wide association analyses based on large subsets of M. truncatula-aligned markers revealed many SNPs with modest association with yield, and some genome areas hosting putative QTLs. A comparison of genomic vs. conventional selection for parent breeding value assuming 1-year vs. 5-year selection cycles, respectively, indicated over three-fold greater predicted yield gain per unit time for genomic selection

  8. 100% classification accuracy considered harmful: the normalized information transfer factor explains the accuracy paradox.

    Directory of Open Access Journals (Sweden)

    Francisco J Valverde-Albacete

    Full Text Available The most widely spread measure of performance, accuracy, suffers from a paradox: predictive models with a given level of accuracy may have greater predictive power than models with higher accuracy. Despite optimizing classification error rate, high accuracy models may fail to capture crucial information transfer in the classification task. We present evidence of this behavior by means of a combinatorial analysis where every possible contingency matrix of 2, 3 and 4 classes classifiers are depicted on the entropy triangle, a more reliable information-theoretic tool for classification assessment. Motivated by this, we develop from first principles a measure of classification performance that takes into consideration the information learned by classifiers. We are then able to obtain the entropy-modulated accuracy (EMA, a pessimistic estimate of the expected accuracy with the influence of the input distribution factored out, and the normalized information transfer factor (NIT, a measure of how efficient is the transmission of information from the input to the output set of classes. The EMA is a more natural measure of classification performance than accuracy when the heuristic to maximize is the transfer of information through the classifier instead of classification error count. The NIT factor measures the effectiveness of the learning process in classifiers and also makes it harder for them to "cheat" using techniques like specialization, while also promoting the interpretability of results. Their use is demonstrated in a mind reading task competition that aims at decoding the identity of a video stimulus based on magnetoencephalography recordings. We show how the EMA and the NIT factor reject rankings based in accuracy, choosing more meaningful and interpretable classifiers.

  9. Improving on the diagnostic characteristics of echocardiography for pulmonary hypertension.

    Science.gov (United States)

    Broderick-Forsgren, Kathleen; Davenport, Clemontina A; Sivak, Joseph A; Hargett, Charles William; Foster, Michael C; Monteagudo, Andrew; Armour, Alicia; Rajagopal, Sudarshan; Arges, Kristine; Velazquez, Eric J; Samad, Zainab

    2017-09-01

    This retrospective study evaluated the diagnostic characteristics of a combination of echocardiographic parameters for pulmonary hypertension (PH). Right ventricular systolic pressure (RVSP) estimation by echocardiography (echo) is used to screen for PH. However, the sensitivity of this method is suboptimal. We hypothesized that RVSP estimation in conjunction with other echo parameters would improve the value of echo for PH. The Duke Echo database was queried for adult patients with known or suspected PH who had undergone both echo and right heart catheterization (RHC) within a 24 h period between 1/1/2008 and 12/31/2013. Patients with complex congenital heart disease, heart transplantation, ventricular assist device, or on mechanical ventilation at time of study were excluded. Diagnostic characteristics of several echo parameters (right atrial enlargement, pulmonary artery (PA) enlargement, RV enlargement, RV dysfunction, and RVSP) for PH (mean PA pressure 25 mmHg on RHC) were evaluated among 1007 patients. RVSP ≥40 had a sensitivity of 77% (accuracy 77), while RVSP ≥35 had the highest sensitivity at 88% (81% accuracy). PA enlargement had the lowest sensitivity at 17%. The area under the curve (AUC) for RVSP was 0.844. A model including RVSP, RA, PA, RV enlargement and RV dysfunction had a higher AUC (AUC = 0.87) than RVSP alone. The value of echo as a screening test for PH is improved by a model incorporating a lower RVSP in addition to other right heart parameters. These findings need to be validated in prospective cohorts.

  10. Residual Convolutional Neural Network for the Determination of IDH Status in Low- and High-Grade Gliomas from MR Imaging.

    Science.gov (United States)

    Chang, Ken; Bai, Harrison X; Zhou, Hao; Su, Chang; Bi, Wenya Linda; Agbodza, Ena; Kavouridis, Vasileios K; Senders, Joeky T; Boaro, Alessandro; Beers, Andrew; Zhang, Biqi; Capellini, Alexandra; Liao, Weihua; Shen, Qin; Li, Xuejun; Xiao, Bo; Cryan, Jane; Ramkissoon, Shakti; Ramkissoon, Lori; Ligon, Keith; Wen, Patrick Y; Bindra, Ranjit S; Woo, John; Arnaout, Omar; Gerstner, Elizabeth R; Zhang, Paul J; Rosen, Bruce R; Yang, Li; Huang, Raymond Y; Kalpathy-Cramer, Jayashree

    2018-03-01

    Purpose: Isocitrate dehydrogenase ( IDH ) mutations in glioma patients confer longer survival and may guide treatment decision making. We aimed to predict the IDH status of gliomas from MR imaging by applying a residual convolutional neural network to preoperative radiographic data. Experimental Design: Preoperative imaging was acquired for 201 patients from the Hospital of University of Pennsylvania (HUP), 157 patients from Brigham and Women's Hospital (BWH), and 138 patients from The Cancer Imaging Archive (TCIA) and divided into training, validation, and testing sets. We trained a residual convolutional neural network for each MR sequence (FLAIR, T2, T1 precontrast, and T1 postcontrast) and built a predictive model from the outputs. To increase the size of the training set and prevent overfitting, we augmented the training set images by introducing random rotations, translations, flips, shearing, and zooming. Results: With our neural network model, we achieved IDH prediction accuracies of 82.8% (AUC = 0.90), 83.0% (AUC = 0.93), and 85.7% (AUC = 0.94) within training, validation, and testing sets, respectively. When age at diagnosis was incorporated into the model, the training, validation, and testing accuracies increased to 87.3% (AUC = 0.93), 87.6% (AUC = 0.95), and 89.1% (AUC = 0.95), respectively. Conclusions: We developed a deep learning technique to noninvasively predict IDH genotype in grade II-IV glioma using conventional MR imaging using a multi-institutional data set. Clin Cancer Res; 24(5); 1073-81. ©2017 AACR . ©2017 American Association for Cancer Research.

  11. Accuracy assessment of modeling architectural structures and details using terrestrial laser scanning

    Directory of Open Access Journals (Sweden)

    M. Kedzierski

    2015-08-01

    Full Text Available One of the most important aspects when performing architectural documentation of cultural heritage structures is the accuracy of both the data and the products which are generated from these data: documentation in the form of 3D models or vector drawings. The paper describes an assessment of the accuracy of modelling data acquired using a terrestrial phase scanner in relation to the density of a point cloud representing the surface of different types of construction materials typical for cultural heritage structures. This analysis includes the impact of the scanning geometry: the incidence angle of the laser beam and the scanning distance. For the purposes of this research, a test field consisting of samples of different types of construction materials (brick, wood, plastic, plaster, a ceramic tile, sheet metal was built. The study involved conducting measurements at different angles and from a range of distances for chosen scanning densities. Data, acquired in the form of point clouds, were then filtered and modelled. An accuracy assessment of the 3D model was conducted by fitting it with the point cloud. The reflection intensity of each type of material was also analyzed, trying to determine which construction materials have the highest reflectance coefficients, and which have the lowest reflection coefficients, and in turn how this variable changes for different scanning parameters. Additionally measurements were taken of a fragment of a building in order to compare the results obtained in laboratory conditions, with those taken in field conditions.

  12. Diagnosing Eyewitness Accuracy

    OpenAIRE

    Russ, Andrew

    2015-01-01

    Eyewitnesses frequently mistake innocent people for the perpetrator of an observed crime. Such misidentifications have led to the wrongful convictions of many people. Despite this, no reliable method yet exists to determine eyewitness accuracy. This thesis explored two new experimental methods for this purpose. Chapter 2 investigated whether repetition priming can measure prior exposure to a target and compared this with observers’ explicit eyewitness accuracy. Across three experiments slower...

  13. Predictive performance of three practical approaches for grapefruit juice-induced 2-fold or greater increases in AUC of concomitantly administered drugs.

    Science.gov (United States)

    Takahashi, M; Onozawa, S; Ogawa, R; Uesawa, Y; Echizen, H

    2015-02-01

    Clinical pharmacists have a challenging task when answering patients' question about whether they can take specific drugs with grapefruit juice (GFJ) without risk of drug interaction. To identify the most practicable method for predicting clinically relevant changes in plasma concentrations of orally administered drugs caused by the ingestion of GFJ, we compared the predictive performance of three methods using data obtained from the literature. We undertook a systematic search of drug interactions associated with GFJ using MEDLINE and the Metabolism & Transport Drug Interaction Database (DIDB version 4.0). We considered an elevation of the area under the plasma concentration-time curve (AUC) of 2 or greater relative to the control value [AUC ratio (AUCR) ≥ 2.0] as a clinically significant interaction. The data from 74 drugs (194 data sets) were analysed. When the reported information of CYP3A involvement in the metabolism of a drug of interest was adopted as a predictive criterion for GFJ-drug interaction, the performance assessed by positive predictive value (PPV) was low (0.26), but that assessed by negative predictive value (NPV) and sensitivity was high (1.00 for both). When the reported oral bioavailability of ≤ 0.1 was used as a criterion, the PPV improved to 0.50 with an acceptable NPV of 0.81, but sensitivity was reduced to 0.21. When the reported AUCR was ≥ 10 after co-administration of a typical CYP3A inhibitor, the corresponding values were 0.64, 0.79 and 0.19, respectively. We consider that an oral bioavailability of ≤ 0.1 or an AUCR of ≥ 10 caused by a CYP3A inhibitor of a drug of interest may be a practical prediction criterion for avoiding significant interactions with GFJ. Information about the involvement of CYP3A in their metabolism should also be taken into account for drugs with narrow therapeutic ranges. © 2014 John Wiley & Sons Ltd.

  14. Trait Perception Accuracy and Acquaintance Within Groups: Tracking Accuracy Development.

    Science.gov (United States)

    Brown, Jill A; Bernieri, Frank

    2017-05-01

    Previous work on trait perception has evaluated accuracy at discrete stages of relationships (e.g., strangers, best friends). A relatively limited body of literature has investigated changes in accuracy as acquaintance within a dyad or group increases. Small groups of initially unacquainted individuals spent more than 30 hr participating in a wide range of activities designed to represent common interpersonal contexts (e.g., eating, traveling). We calculated how accurately each participant judged others in their group on the big five traits across three distinct points within the acquaintance process: zero acquaintance, after a getting-to-know-you conversation, and after 10 weeks of interaction and activity. Judgments of all five traits exhibited accuracy above chance levels after 10 weeks. An examination of the trait rating stability revealed that much of the revision in judgments occurred not over the course of the 10-week relationship as suspected, but between zero acquaintance and the getting-to-know-you conversation.

  15. Improvement in the accuracy of polymer gel dosimeters using scintillating fibers

    International Nuclear Information System (INIS)

    Tremblay, Nicolas M; Hubert-Tremblay, Vincent; Bujold, Rachel; Beaulieu, Luc; Lepage, Martin

    2010-01-01

    We propose a novel method for the absolute calibration of polyacrylamide gel (PAG) dosimeters with one or more reference scintillating fiber dosimeters inserted inside the gel. Four calibrated scintillating fibers were inserted into a cylindrical glass container filled with a PAG dosimeter irradiated with a wedge filtered 6 MV photon beam. Calibration curves using small glass vials containing the same gel as the cylindrical containers were used to obtain a first calibration curve. This calibration curve was then adjusted with the dose measured with one of the scintillating fibers in a low gradient part of the field using different approaches. Among these, it was found that a translation of the gel calibration curve yielded the highest accuracy with PAG dosimeters.

  16. Use of Contrast-Enhanced Ultrasound to Study Relationship between Serum Uric Acid and Renal Microvascular Perfusion in Diabetic Kidney Disease

    Directory of Open Access Journals (Sweden)

    Ling Wang

    2015-01-01

    Full Text Available Purpose. To investigate the relationship between uric acid and renal microvascular perfusion in diabetic kidney disease (DKD using contrast-enhanced ultrasound (CEUS method. Materials and Methods. 79 DKD patients and 26 healthy volunteers were enrolled. Renal function and urine protein markers were tested. DKD patients were subdivided into two groups including a normal serum uric acid (SUA group and a high SUA group. Contrast-enhanced ultrasound (CEUS was performed, and low acoustic power contrast-specific imaging was used for quantitative analysis. Results. Normal controls (NCs had the highest levels of AUC, AUC1, and AUC2. Compared to the normal SUA DKD group, high SUA DKD patients had significantly higher IMAX, AUC, and AUC1 (P<0.05. DKD patients with low urinary uric acid (UUA excretion had significantly higher AUC2 compared to DKD patients with normal UUA (P<0.05. Conclusion. Hyperuricemia in DKD patients was associated with a renal ultrasound image suggestive of microvascular hyperperfusion. The CEUS parameter AUC1 holds promise as an indicator for renal microvascular hyperperfusion, while AUC2 might be a useful indicator of declining glomerular filtration rate in DKD patients with decreased excretion of uric acid.

  17. Diagnostic Accuracy of Clinical Examination and Imaging Findings for Identifying Subacromial Pain.

    Science.gov (United States)

    Cadogan, Angela; McNair, Peter J; Laslett, Mark; Hing, Wayne A

    2016-01-01

    The diagnosis of subacromial pathology is limited by the poor accuracy of clinical tests for specific pathologies. The aim of this study was to estimate the diagnostic accuracy of clinical examination and imaging features for identifying subacromial pain (SAP) defined by a positive response to diagnostic injection, and to evaluate the influence of imaging findings on the clinical diagnosis of SAP. In a prospective, diagnostic accuracy design, 208 consecutive patients presenting to their primary healthcare practitioner for the first time with a new episode of shoulder pain were recruited. All participants underwent a standardized clinical examination, shoulder x-ray series and diagnostic ultrasound scan. Results were compared with the response to a diagnostic block of xylocaineTM injected into the SAB under ultrasound guidance using ≥80% post-injection reduction in pain intensity as the positive anaesthetic response (PAR) criterion. Diagnostic accuracy statistics were calculated for combinations of clinical and imaging variables demonstrating the highest likelihood of a PAR. A PAR was reported by 34% of participants. In participants with no loss of passive external rotation, combinations of three clinical variables (anterior shoulder pain, strain injury, absence of symptoms at end-range external rotation (in abduction)) demonstrated 100% specificity for a PAR when all three were positive (LR+ infinity; 95%CI 2.9, infinity). A full-thickness supraspinatus tear on ultrasound increased the likelihood of a PAR irrespective of age (specificity 98% (95%CI 94, 100); LR+ 6.2; 95% CI 1.5, 25.7)). Imaging did not improve the ability to rule-out a PAR. Combinations of clinical examination findings and a full-thickness supraspinatus tear on ultrasound scan can help confirm, but not exclude, the presence of subacromial pain. Other imaging findings were of limited value for diagnosing SAP.

  18. The ACS NSQIP Risk Calculator Is a Fair Predictor of Acute Periprosthetic Joint Infection.

    Science.gov (United States)

    Wingert, Nathaniel C; Gotoff, James; Parrilla, Edgardo; Gotoff, Robert; Hou, Laura; Ghanem, Elie

    2016-07-01

    Periprosthetic joint infection (PJI) is a severe complication from the patient's perspective and an expensive one in a value-driven healthcare model. Risk stratification can help identify those patients who may have risk factors for complications that can be mitigated in advance of elective surgery. Although numerous surgical risk calculators have been created, their accuracy in predicting outcomes, specifically PJI, has not been tested. (1) How accurate is the American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) Surgical Site Infection Calculator in predicting 30-day postoperative infection? (2) How accurate is the calculator in predicting 90-day postoperative infection? We isolated 1536 patients who underwent 1620 primary THAs and TKAs at our institution during 2011 to 2013. Minimum followup was 90 days. The ACS NSQIP Surgical Risk Calculator was assessed in its ability to predict acute PJI within 30 and 90 days postoperatively. Patients who underwent a repeat surgical procedure within 90 days of the index arthroplasty and in whom at least one positive intraoperative culture was obtained at time of reoperation were considered to have PJI. A total of 19 cases of PJI were identified, including 11 at 30 days and an additional eight instances by 90 days postoperatively. Patient-specific risk probabilities for PJI based on demographics and comorbidities were recorded from the ACS NSQIP Surgical Risk Calculator website. The area under the curve (AUC) for receiver operating characteristic (ROC) curves was calculated to determine the predictability of the risk probability for PJI. The AUC is an effective method for quantifying the discriminatory capacity of a diagnostic test to correctly classify patients with and without infection in which it is defined as excellent (AUC 0.9-1), good (AUC 0.8-0.89), fair (AUC 0.7-0.79), poor (AUC 0.6-0.69), or fail/no discriminatory capacity (AUC 0.5-0.59). A p value of fair accuracy in predicting 30

  19. Compressive sensing-based wideband capacitance measurement with a fixed sampling rate lower than the highest exciting frequency

    International Nuclear Information System (INIS)

    Xu, Lijun; Ren, Ying; Sun, Shijie; Cao, Zhang

    2016-01-01

    In this paper, an under-sampling method for wideband capacitance measurement was proposed by using the compressive sensing strategy. As the excitation signal is sparse in the frequency domain, the compressed sampling method that uses a random demodulator was adopted, which could greatly decrease the sampling rate. Besides, four switches were used to replace the multiplier in the random demodulator. As a result, not only the sampling rate can be much smaller than the signal excitation frequency, but also the circuit’s structure is simpler and its power consumption is lower. A hardware prototype was constructed to validate the method. In the prototype, an excitation voltage with a frequency up to 200 kHz was applied to a capacitance-to-voltage converter. The output signal of the converter was randomly modulated by a pseudo-random sequence through four switches. After a low-pass filter, the signal was sampled by an analog-to-digital converter at a sampling rate of 50 kHz, which was three times lower than the highest exciting frequency. The frequency and amplitude of the signal were then reconstructed to obtain the measured capacitance. Both theoretical analysis and experiments were carried out to show the feasibility of the proposed method and to evaluate the performance of the prototype, including its linearity, sensitivity, repeatability, accuracy and stability within a given measurement range. (paper)

  20. Incorporation of Mobile Application (App) Measures Into the Diagnosis of Smartphone Addiction.

    Science.gov (United States)

    Lin, Yu-Hsuan; Lin, Po-Hsien; Chiang, Chih-Lin; Lee, Yang-Han; Yang, Cheryl C H; Kuo, Terry B J; Lin, Sheng-Hsuan

    2017-07-01

    Global smartphone expansion has brought about unprecedented addictive behaviors. The current diagnosis of smartphone addiction is based solely on information from clinical interview. This study aimed to incorporate application (app)-recorded data into psychiatric criteria for the diagnosis of smartphone addiction and to examine the predictive ability of the app-recorded data for the diagnosis of smartphone addiction. Smartphone use data of 79 college students were recorded by a newly developed app for 1 month between December 1, 2013, and May 31, 2014. For each participant, psychiatrists made a diagnosis for smartphone addiction based on 2 approaches: (1) only diagnostic interview (standard diagnosis) and (2) both diagnostic interview and app-recorded data (app-incorporated diagnosis). The app-incorporated diagnosis was further used to build app-incorporated diagnostic criteria. In addition, the app-recorded data were pooled as a score to predict smartphone addiction diagnosis. When app-incorporated diagnosis was used as a gold standard for 12 candidate criteria, 7 criteria showed significant accuracy (area under receiver operating characteristic curve [AUC] > 0.7) and were constructed as app-incorporated diagnostic criteria, which demonstrated remarkable accuracy (92.4%) for app-incorporated diagnosis. In addition, both frequency and duration of daily smartphone use significantly predicted app-incorporated diagnosis (AUC = 0.70 for frequency; AUC = 0.72 for duration). The combination of duration, frequency, and frequency trend for 1 month can accurately predict smartphone addiction diagnosis (AUC = 0.79 for app-incorporated diagnosis; AUC = 0.71 for standard diagnosis). The app-incorporated diagnosis, combining both psychiatric interview and app-recorded data, demonstrated substantial accuracy for smartphone addiction diagnosis. In addition, the app-recorded data performed as an accurate screening tool for app-incorporated diagnosis. © Copyright 2017 Physicians

  1. Modeling landslide susceptibility in data-scarce environments using optimized data mining and statistical methods

    Science.gov (United States)

    Lee, Jung-Hyun; Sameen, Maher Ibrahim; Pradhan, Biswajeet; Park, Hyuck-Jin

    2018-02-01

    This study evaluated the generalizability of five models to select a suitable approach for landslide susceptibility modeling in data-scarce environments. In total, 418 landslide inventories and 18 landslide conditioning factors were analyzed. Multicollinearity and factor optimization were investigated before data modeling, and two experiments were then conducted. In each experiment, five susceptibility maps were produced based on support vector machine (SVM), random forest (RF), weight-of-evidence (WoE), ridge regression (Rid_R), and robust regression (RR) models. The highest accuracy (AUC = 0.85) was achieved with the SVM model when either the full or limited landslide inventories were used. Furthermore, the RF and WoE models were severely affected when less landslide samples were used for training. The other models were affected slightly when the training samples were limited.

  2. Social Power Increases Interoceptive Accuracy

    Directory of Open Access Journals (Sweden)

    Mehrad Moeini-Jazani

    2017-08-01

    Full Text Available Building on recent psychological research showing that power increases self-focused attention, we propose that having power increases accuracy in perception of bodily signals, a phenomenon known as interoceptive accuracy. Consistent with our proposition, participants in a high-power experimental condition outperformed those in the control and low-power conditions in the Schandry heartbeat-detection task. We demonstrate that the effect of power on interoceptive accuracy is not explained by participants’ physiological arousal, affective state, or general intention for accuracy. Rather, consistent with our reasoning that experiencing power shifts attentional resources inward, we show that the effect of power on interoceptive accuracy is dependent on individuals’ chronic tendency to focus on their internal sensations. Moreover, we demonstrate that individuals’ chronic sense of power also predicts interoceptive accuracy similar to, and independent of, how their situationally induced feeling of power does. We therefore provide further support on the relation between power and enhanced perception of bodily signals. Our findings offer a novel perspective–a psychophysiological account–on how power might affect judgments and behavior. We highlight and discuss some of these intriguing possibilities for future research.

  3. Validation of the Rowland Universal Dementia Assessment Scale for multicultural screening in Danish memory clinics.

    Science.gov (United States)

    Nielsen, T Rune; Andersen, Birgitte Bo; Gottrup, Hanne; Lützhøft, Jan H; Høgh, Peter; Waldemar, Gunhild

    2013-01-01

    The Rowland Universal Dementia Assessment Scale (RUDAS) is a brief cognitive screening test that was developed to detect dementia in multicultural populations. The RUDAS has not previously been validated in multicultural populations outside of Australia. The aim of this study was to evaluate the diagnostic accuracy of the RUDAS in a multicultural sample of patients referred to Danish memory clinics. Data were collected from 137 consecutive patients (34 with an immigrant background) in three Danish memory clinics. All patients were given the RUDAS as a supplement to the standard diagnostic workup. Diagnostic accuracy for the RUDAS [area under the curve (AUC) = 0.838] was similar to that of the Mini-Mental State Examination (MMSE; AUC = 0.840). The cutoff score with the best balance of sensitivity, specificity and accuracy was multicultural patient populations. © 2013 S. Karger AG, Basel.

  4. Genomic selection prediction accuracy in a perennial crop: case study of oil palm (Elaeis guineensis Jacq.).

    Science.gov (United States)

    Cros, David; Denis, Marie; Sánchez, Leopoldo; Cochard, Benoit; Flori, Albert; Durand-Gasselin, Tristan; Nouy, Bruno; Omoré, Alphonse; Pomiès, Virginie; Riou, Virginie; Suryana, Edyana; Bouvet, Jean-Marc

    2015-03-01

    Genomic selection empirically appeared valuable for reciprocal recurrent selection in oil palm as it could account for family effects and Mendelian sampling terms, despite small populations and low marker density. Genomic selection (GS) can increase the genetic gain in plants. In perennial crops, this is expected mainly through shortened breeding cycles and increased selection intensity, which requires sufficient GS accuracy in selection candidates, despite often small training populations. Our objective was to obtain the first empirical estimate of GS accuracy in oil palm (Elaeis guineensis), the major world oil crop. We used two parental populations involved in conventional reciprocal recurrent selection (Deli and Group B) with 131 individuals each, genotyped with 265 SSR. We estimated within-population GS accuracies when predicting breeding values of non-progeny-tested individuals for eight yield traits. We used three methods to sample training sets and five statistical methods to estimate genomic breeding values. The results showed that GS could account for family effects and Mendelian sampling terms in Group B but only for family effects in Deli. Presumably, this difference between populations originated from their contrasting breeding history. The GS accuracy ranged from -0.41 to 0.94 and was positively correlated with the relationship between training and test sets. Training sets optimized with the so-called CDmean criterion gave the highest accuracies, ranging from 0.49 (pulp to fruit ratio in Group B) to 0.94 (fruit weight in Group B). The statistical methods did not affect the accuracy. Finally, Group B could be preselected for progeny tests by applying GS to key yield traits, therefore increasing the selection intensity. Our results should be valuable for breeding programs with small populations, long breeding cycles, or reduced effective size.

  5. The value of intratumoral heterogeneity of (18)F-FDG uptake to differentiate between primary benign and malignant musculoskeletal tumours on PET/CT.

    Science.gov (United States)

    Nakajo, Masatoyo; Nakajo, Masayuki; Jinguji, Megumi; Fukukura, Yoshihiko; Nakabeppu, Yoshiaki; Tani, Atsushi; Yoshiura, Takashi

    2015-01-01

    The cumulative standardized uptake value (SUV)-volume histogram (CSH) was reported to be a novel way to characterize heterogeneity in intratumoral tracer uptake. This study investigated the value of fluorine-18 fludeoxyglucose ((18)F-FDG) intratumoral heterogeneity in comparison with SUV to discriminate between primary benign and malignant musculoskeletal (MS) tumours. The subjects comprised 85 pathologically proven MS tumours. The area under the curve of CSH (AUC-CSH) was used as a heterogeneity index, with lower values corresponding with increased heterogeneity. As 22 tumours were indiscernible on (18)F-FDG positron emission tomography, maximum standardized uptake value (SUVmax), mean standardized uptake value (SUVmean) and AUC-CSH were obtained in 63 positive tumours. The Mann-Whitney U test and receiver operating characteristic (ROC) analysis were used for analyses. The difference between benign (n = 35) and malignant tumours (n = 28) was significant in AUC-CSH (p = 0.004), but not in SUVmax (p = 0.168) and SUVmean (p = 0.879). The sensitivity, specificity and accuracy for diagnosing malignancy were 61%, 66% and 64% for SUVmax (optical threshold value, >6.9), 54%, 60% and 57% for SUVmean (optical threshold value, >3) and 61%, 86% and 75% for AUC-CSH (optical threshold value, ≤0.42), respectively. The area under the ROC curve was significantly higher in AUC-CSH (0.71) than SUVmax (0.60) (p = 0.018) and SUVmean (0.51) (p = 0.005). The heterogeneity index, AUC-CSH, has a higher diagnostic accuracy than SUV analysis in differentiating between primary benign and malignant MS tumours, although it is not sufficiently high enough to obviate histological analysis. AUC-CSH can assess the heterogeneity of (18)F-FDG uptake in primary benign and malignant MS tumours, with significantly greater heterogeneity associated with malignant MS tumours. AUC-CSH is more diagnostically accurate than SUV analysis in differentiating between benign and

  6. Comparative study of ultrasonography, computed tomography, magnetic resonance imaging, and magnetic resonance spectroscopy for the diagnosis for fatty liver in a rat model

    International Nuclear Information System (INIS)

    Noh, Hoon; Song, Xiao Li; Heo, Suk Hee; Kim, Jin Woong; Jeong, Yong Yeon; Kang, Heoung Keun; Shin, Sang Soo; Ahn, Kyu Youn

    2017-01-01

    To compare the accuracy of ultrasonography (US), single-energy CT (SECT), dual-energy CT (DECT), MR imaging (MRI), and MR spectroscopy (MRS) for detecting fatty liver in a rat model. Fatty liver was induced by 60% high-fat diet for 1, 2, 3, 4, or 5 weeks (3 rats per group, a total of 15 rats). The control group comprised of five rats fed 10% high-fat diet. US, SECT, DECT, MRI, and MRS of the liver were performed weekly. Histologic steatosis grade and intrahepatocelluar triglyceride level were determined histologically for the livers of sacrificed rats. Pearson correlation test was used to assess the correlation between examinations and standard reference levels. Receiver operating characteristic curves were constructed. Area under the curve (AUC), sensitivity, and specificity were calculated. US, SECT, DECT, MRI, and MRS were significantly correlated with histologic steatosis grade. The diagnostic performance of AUC, sensitivity, and specificity were 0.893, 80%, and 80% for US, 0.960, 80%, and 80% for SECT, 0.947, 100%, and 60% for DECT, 0.933, 93.3%, and 100% for MRI, and 0.960, 93.3%, and 100% for MRS. MRS showed the strongest correlation with histologic steatosis grade with the highest sensitivity and specificity for diagnosis of fatty liver compared to other modalities

  7. Diagnostic value of combined determination of serum and chest fluid adenosine deaminase (ADA), IL-2, IL-6, IL-10 contents for differentiation of tuberculous from malignant pleural effusion

    International Nuclear Information System (INIS)

    Wu Jiaming; Wang Limin

    2005-01-01

    Objective: To investigate the possible diagnostic value of combined determination of serum and chest fluid contents of ADA, IL-2, IL-6, IL-10 in patients with tuberculous and malignant pleural effusion. Methods: Serum and chest fluid ADA (with biochemical method), IL-2, IL-6, IL-10 (with ELISA) contents were measured in 56 patients with tuberculosis pleural effusion, 53 patients with malignant effusion and 30 controls (in serum only). The receiving operative characteristic (ROC) curve for each parameter was analyzed for study of respective area under curse (Auc). Results: The serum IL-6 levels in both groups of patients were significantly higher than those in the controls (P<0.05). The chest fluid contents of ADA, IL-2, IL-6 and IL-10 in patients with tuberculous effusion were all significantly higher than those in patients with malignancies (P<0.05). The Auc in the ROC was largest in the case of ADA, followed by IL-10, IL-6 with IL-2 the least. Conclusion: Determination of chest fluid ADA, IL-2, IL-6, IL-10 contents was helpful in the differentiation of tuberculous from malignant pleural effusion. Combined determination of chest fluid ADA and IL-10 provided the highest accuracy rate for differentional diagnosis. (authors)

  8. Comparative study of ultrasonography, computed tomography, magnetic resonance imaging, and magnetic resonance spectroscopy for the diagnosis for fatty liver in a rat model

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Hoon; Song, Xiao Li; Heo, Suk Hee; Kim, Jin Woong; Jeong, Yong Yeon; Kang, Heoung Keun [Dept. of Radiology, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of); Shin, Sang Soo [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Ahn, Kyu Youn [Dept. of Anatomy, Chonnam National University Medical School, Gwangju (Korea, Republic of)

    2017-01-15

    To compare the accuracy of ultrasonography (US), single-energy CT (SECT), dual-energy CT (DECT), MR imaging (MRI), and MR spectroscopy (MRS) for detecting fatty liver in a rat model. Fatty liver was induced by 60% high-fat diet for 1, 2, 3, 4, or 5 weeks (3 rats per group, a total of 15 rats). The control group comprised of five rats fed 10% high-fat diet. US, SECT, DECT, MRI, and MRS of the liver were performed weekly. Histologic steatosis grade and intrahepatocelluar triglyceride level were determined histologically for the livers of sacrificed rats. Pearson correlation test was used to assess the correlation between examinations and standard reference levels. Receiver operating characteristic curves were constructed. Area under the curve (AUC), sensitivity, and specificity were calculated. US, SECT, DECT, MRI, and MRS were significantly correlated with histologic steatosis grade. The diagnostic performance of AUC, sensitivity, and specificity were 0.893, 80%, and 80% for US, 0.960, 80%, and 80% for SECT, 0.947, 100%, and 60% for DECT, 0.933, 93.3%, and 100% for MRI, and 0.960, 93.3%, and 100% for MRS. MRS showed the strongest correlation with histologic steatosis grade with the highest sensitivity and specificity for diagnosis of fatty liver compared to other modalities.

  9. Ultra-high accuracy optical testing: creating diffraction-limitedshort-wavelength optical systems

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Kenneth A.; Naulleau, Patrick P.; Rekawa, Senajith B.; Denham, Paul E.; Liddle, J. Alexander; Gullikson, Eric M.; Jackson, KeithH.; Anderson, Erik H.; Taylor, John S.; Sommargren, Gary E.; Chapman,Henry N.; Phillion, Donald W.; Johnson, Michael; Barty, Anton; Soufli,Regina; Spiller, Eberhard A.; Walton, Christopher C.; Bajt, Sasa

    2005-08-03

    Since 1993, research in the fabrication of extreme ultraviolet (EUV) optical imaging systems, conducted at Lawrence Berkeley National Laboratory (LBNL) and Lawrence Livermore National Laboratory (LLNL), has produced the highest resolution optical systems ever made. We have pioneered the development of ultra-high-accuracy optical testing and alignment methods, working at extreme ultraviolet wavelengths, and pushing wavefront-measuring interferometry into the 2-20-nm wavelength range (60-600 eV). These coherent measurement techniques, including lateral shearing interferometry and phase-shifting point-diffraction interferometry (PS/PDI) have achieved RMS wavefront measurement accuracies of 0.5-1-{angstrom} and better for primary aberration terms, enabling the creation of diffraction-limited EUV optics. The measurement accuracy is established using careful null-testing procedures, and has been verified repeatedly through high-resolution imaging. We believe these methods are broadly applicable to the advancement of short-wavelength optical systems including space telescopes, microscope objectives, projection lenses, synchrotron beamline optics, diffractive and holographic optics, and more. Measurements have been performed on a tunable undulator beamline at LBNL's Advanced Light Source (ALS), optimized for high coherent flux; although many of these techniques should be adaptable to alternative ultraviolet, EUV, and soft x-ray light sources. To date, we have measured nine prototype all-reflective EUV optical systems with NA values between 0.08 and 0.30 (f/6.25 to f/1.67). These projection-imaging lenses were created for the semiconductor industry's advanced research in EUV photolithography, a technology slated for introduction in 2009-13. This paper reviews the methods used and our program's accomplishments to date.

  10. Deep Convolutional Neural Networks for Endotracheal Tube Position and X-ray Image Classification: Challenges and Opportunities.

    Science.gov (United States)

    Lakhani, Paras

    2017-08-01

    The goal of this study is to evaluate the efficacy of deep convolutional neural networks (DCNNs) in differentiating subtle, intermediate, and more obvious image differences in radiography. Three different datasets were created, which included presence/absence of the endotracheal (ET) tube (n = 300), low/normal position of the ET tube (n = 300), and chest/abdominal radiographs (n = 120). The datasets were split into training, validation, and test. Both untrained and pre-trained deep neural networks were employed, including AlexNet and GoogLeNet classifiers, using the Caffe framework. Data augmentation was performed for the presence/absence and low/normal ET tube datasets. Receiver operating characteristic (ROC), area under the curves (AUC), and 95% confidence intervals were calculated. Statistical differences of the AUCs were determined using a non-parametric approach. The pre-trained AlexNet and GoogLeNet classifiers had perfect accuracy (AUC 1.00) in differentiating chest vs. abdominal radiographs, using only 45 training cases. For more difficult datasets, including the presence/absence and low/normal position endotracheal tubes, more training cases, pre-trained networks, and data-augmentation approaches were helpful to increase accuracy. The best-performing network for classifying presence vs. absence of an ET tube was still very accurate with an AUC of 0.99. However, for the most difficult dataset, such as low vs. normal position of the endotracheal tube, DCNNs did not perform as well, but achieved a reasonable AUC of 0.81.

  11. Systematic review of discharge coding accuracy

    Science.gov (United States)

    Burns, E.M.; Rigby, E.; Mamidanna, R.; Bottle, A.; Aylin, P.; Ziprin, P.; Faiz, O.D.

    2012-01-01

    Introduction Routinely collected data sets are increasingly used for research, financial reimbursement and health service planning. High quality data are necessary for reliable analysis. This study aims to assess the published accuracy of routinely collected data sets in Great Britain. Methods Systematic searches of the EMBASE, PUBMED, OVID and Cochrane databases were performed from 1989 to present using defined search terms. Included studies were those that compared routinely collected data sets with case or operative note review and those that compared routinely collected data with clinical registries. Results Thirty-two studies were included. Twenty-five studies compared routinely collected data with case or operation notes. Seven studies compared routinely collected data with clinical registries. The overall median accuracy (routinely collected data sets versus case notes) was 83.2% (IQR: 67.3–92.1%). The median diagnostic accuracy was 80.3% (IQR: 63.3–94.1%) with a median procedure accuracy of 84.2% (IQR: 68.7–88.7%). There was considerable variation in accuracy rates between studies (50.5–97.8%). Since the 2002 introduction of Payment by Results, accuracy has improved in some respects, for example primary diagnoses accuracy has improved from 73.8% (IQR: 59.3–92.1%) to 96.0% (IQR: 89.3–96.3), P= 0.020. Conclusion Accuracy rates are improving. Current levels of reported accuracy suggest that routinely collected data are sufficiently robust to support their use for research and managerial decision-making. PMID:21795302

  12. Ultra-high accuracy optical testing: creating diffraction-limited short-wavelength optical systems

    International Nuclear Information System (INIS)

    Goldberg, Kenneth A.; Naulleau, Patrick P.; Rekawa, Senajith B.; Denham, Paul E.; Liddle, J. Alexander; Gullikson, Eric M.; Jackson, KeithH.; Anderson, Erik H.; Taylor, John S.; Sommargren, Gary E.; Chapman, Henry N.; Phillion, Donald W.; Johnson, Michael; Barty, Anton; Soufli, Regina; Spiller, Eberhard A.; Walton, Christopher C.; Bajt, Sasa

    2005-01-01

    Since 1993, research in the fabrication of extreme ultraviolet (EUV) optical imaging systems, conducted at Lawrence Berkeley National Laboratory (LBNL) and Lawrence Livermore National Laboratory (LLNL), has produced the highest resolution optical systems ever made. We have pioneered the development of ultra-high-accuracy optical testing and alignment methods, working at extreme ultraviolet wavelengths, and pushing wavefront-measuring interferometry into the 2-20-nm wavelength range (60-600 eV). These coherent measurement techniques, including lateral shearing interferometry and phase-shifting point-diffraction interferometry (PS/PDI) have achieved RMS wavefront measurement accuracies of 0.5-1-(angstrom) and better for primary aberration terms, enabling the creation of diffraction-limited EUV optics. The measurement accuracy is established using careful null-testing procedures, and has been verified repeatedly through high-resolution imaging. We believe these methods are broadly applicable to the advancement of short-wavelength optical systems including space telescopes, microscope objectives, projection lenses, synchrotron beamline optics, diffractive and holographic optics, and more. Measurements have been performed on a tunable undulator beamline at LBNL's Advanced Light Source (ALS), optimized for high coherent flux; although many of these techniques should be adaptable to alternative ultraviolet, EUV, and soft x-ray light sources. To date, we have measured nine prototype all-reflective EUV optical systems with NA values between 0.08 and 0.30 (f/6.25 to f/1.67). These projection-imaging lenses were created for the semiconductor industry's advanced research in EUV photolithography, a technology slated for introduction in 2009-13. This paper reviews the methods used and our program's accomplishments to date

  13. Automatic Detection of Compensation During Robotic Stroke Rehabilitation Therapy.

    Science.gov (United States)

    Zhi, Ying Xuan; Lukasik, Michelle; Li, Michael H; Dolatabadi, Elham; Wang, Rosalie H; Taati, Babak

    2018-01-01

    Robotic stroke rehabilitation therapy can greatly increase the efficiency of therapy delivery. However, when left unsupervised, users often compensate for limitations in affected muscles and joints by recruiting unaffected muscles and joints, leading to undesirable rehabilitation outcomes. This paper aims to develop a computer vision system that augments robotic stroke rehabilitation therapy by automatically detecting such compensatory motions. Nine stroke survivors and ten healthy adults participated in this study. All participants completed scripted motions using a table-top rehabilitation robot. The healthy participants also simulated three types of compensatory motions. The 3-D trajectories of upper body joint positions tracked over time were used for multiclass classification of postures. A support vector machine (SVM) classifier detected lean-forward compensation from healthy participants with excellent accuracy (AUC = 0.98, F1 = 0.82), followed by trunk-rotation compensation (AUC = 0.77, F1 = 0.57). Shoulder-elevation compensation was not well detected (AUC = 0.66, F1 = 0.07). A recurrent neural network (RNN) classifier, which encodes the temporal dependency of video frames, obtained similar results. In contrast, F1-scores in stroke survivors were low for all three compensations while using RNN: lean-forward compensation (AUC = 0.77, F1 = 0.17), trunk-rotation compensation (AUC = 0.81, F1 = 0.27), and shoulder-elevation compensation (AUC = 0.27, F1 = 0.07). The result was similar while using SVM. To improve detection accuracy for stroke survivors, future work should focus on predefining the range of motion, direct camera placement, delivering exercise intensity tantamount to that of real stroke therapies, adjusting seat height, and recording full therapy sessions.

  14. Diagnostic performance of a Lattice Boltzmann-based method for CT-based fractional flow reserve.

    Science.gov (United States)

    Giannopoulos, Andreas A; Tang, Anji; Ge, Yin; Cheezum, Michael K; Steigner, Michael L; Fujimoto, Shinichiro; Kumamaru, Kanako K; Chiappino, Dante; Della Latta, Daniele; Berti, Sergio; Chiappino, Sara; Rybicki, Frank J; Melchionna, Simone; Mitsouras, Dimitrios

    2018-02-20

    Fractional flow reserve (FFR) estimated from coronary computed tomography angiography (CT-FFR) offers non-invasive detection of lesion-specific ischaemia. We aimed to develop and validate a fast CT-FFR algorithm utilising the Lattice Boltzmann method for blood flow simulation (LBM CT-FFR). Sixty-four patients with clinically indicated CTA and invasive FFR measurement from three institutions were retrospectively analysed. CT-FFR was performed using an onsite tool interfacing with a commercial Lattice Boltzmann fluid dynamics cloud-based platform. Diagnostic accuracy of LBM CT-FFR ≤0.8 and percent diameter stenosis >50% by CTA to detect invasive FFR ≤0.8 were compared using area under the receiver operating characteristic curve (AUC). Sixty patients successfully underwent LBM CT-FFR analysis; 29 of 73 lesions in 69 vessels had invasive FFR ≤0.8. Total time to perform LBM CT-FFR was 40±10 min. Compared to invasive FFR, LBM CT-FFR had good correlation (r=0.64), small bias (0.009) and good limits of agreement (-0.223 to 0.206). The AUC of LBM CT-FFR (AUC=0.894, 95% confidence interval [CI]: 0.792-0.996) was significantly higher than CTA (AUC=0.685, 95% CI: 0.576-0.794) to detect FFR ≤0.8 (p=0.0021). Per-lesion specificity, sensitivity, and accuracy of LBM CT-FFR were 97.7%, 79.3%, and 90.4%, respectively. LBM CT-FFR has very good diagnostic accuracy to detect lesion-specific ischaemia (FFR ≤0.8) and can be performed in less than one hour.

  15. Biología reproductiva de Convolvulus chilensis (Convolvulaceae en una población de Aucó (centro-norte de Chile Reproductive biology of Convolvulus chilensis (Convolvulaceae in a population of Aucó (north-central Chile

    Directory of Open Access Journals (Sweden)

    Lorena H. Suárez

    2004-12-01

    Full Text Available Convolvulus chilensis es una hierba perenne, única representante endémica de la familia Convolvulaceae en Chile. Se estudió el sistema de reproducción, fenología, morfología y longevidad floral de C. chilensis en una población natural ubicada en la localidad de Aucó, dentro de la Reserva Nacional Las Chinchillas, IV Región, Chile. Se montó un experimento de polinización controlada considerando los tratamientos de polinización natural, polinización cruzada, autopolinización manual, autopolinización automática y apomixis, evaluándose su efecto sobre la formación de frutos y el número de semillas producidas por fruto. Adicionalmente, se compararon los siguientes atributos de la progenie según tipo de polinización (autopolinización o polinización cruzada: peso de semilla, germinación, altura y número de hojas de plántulas de ocho semanas en condiciones de invernadero. Se encontró que C. chilensis es una especie autocompatible, parcialmente autógama (capaz de autopolinizarse sin mediador y parcialmente apomíctica (capaz de producir semillas sin participación de gameto masculino. La longevidad floral fue estimada en 5,25 h. Durante este período, aproximadamente en 1,5 h hay disponibilidad de polen en los estambres. El período de floración se extiende por 22 semanas (agosto a enero. El tratamiento de apomixis presentó el menor porcentaje de formación de frutos y la menor cantidad de semillas por flor en comparación a los tratamientos de polinización natural, cruzada manual, autopolinización automática y autopolinización manual, los cuales no mostraron diferencias entre sí en ambos atributos. El tipo de polinización (autopolinización o polinización cruzada no afecta el desempeño de la progenie en los atributos de semilla y plántula evaluadosThe perennial herb Convolvulus chilensis is the only endemic species of the Convolvulaceae in Chile. The breeding system, phenology, morphology and floral longevity of C

  16. Robert Aymar receives one of the highest Finnish distinctions

    CERN Multimedia

    2008-01-01

    On 9 December 2008 Robert Aymar, CERN Director-General, was awarded the decoration of Commander, first class, of the Order of the Lion of Finland by the President of the Republic of Finland. This decoration, one of the highest of Finland, was presented in a ceremony by the Ambassador Hannu Himanen, Permanent Representative of Finland to the UN and other international organisations in Geneva. Robert Aymar was honoured for his service to CERN, the LHC, his role in the cooperation between Finland and CERN, as well as his contribution to science in general. In his speech the ambassador underlined CERN’s efforts in the field of education, mentioning the High school teachers programme.

  17. Classification of the financial sustainability of health insurance beneficiaries through data mining techniques

    Directory of Open Access Journals (Sweden)

    Sílvia Maria Dias Pedro Rebouças

    2016-09-01

    Full Text Available Advances in information technologies have led to the storage of large amounts of data by organizations. An analysis of this data through data mining techniques is important support for decision-making. This article aims to apply techniques for the classification of the beneficiaries of an operator of health insurance in Brazil, according to their financial sustainability, via their sociodemographic characteristics and their healthcare cost history. Beneficiaries with a loss ratio greater than 0.75 are considered unsustainable. The sample consists of 38875 beneficiaries, active between the years 2011 and 2013. The techniques used were logistic regression and classification trees. The performance of the models was compared to accuracy rates and receiver operating Characteristic curves (ROC curves, by determining the area under the curves (AUC. The results showed that most of the sample is composed of sustainable beneficiaries. The logistic regression model had a 68.43% accuracy rate with AUC of 0.7501, and the classification tree obtained 67.76% accuracy and an AUC of 0.6855. Age and the type of plan were the most important variables related to the profile of the beneficiaries in the classification. The highlights with regard to healthcare costs were annual spending on consultation and on dental insurance.

  18. Relationship between Blood Stasis Syndrome Score and Cardioankle Vascular Index in Stroke Patients

    Directory of Open Access Journals (Sweden)

    Ki-Ho Cho

    2012-01-01

    Full Text Available Blood stasis syndrome (BSS in traditional Asian medicine has been considered to correlate with the extent of atherosclerosis, which can be estimated using the cardioankle vascular index (CAVI. Here, the diagnostic utility of CAVI in predicting BSS was examined. The BSS scores and CAVI were measured in 140 stroke patients and evaluated with respect to stroke risk factors. Receiver operating characteristic (ROC curve analysis was used to determine the diagnostic accuracy of CAVI for the diagnosis of BSS. The BSS scores correlated significantly with CAVI, age, and systolic blood pressure (SBP. Multiple logistic regression analysis showed that CAVI was a significant associate factor for BSS (OR 1.55, P=0.032 after adjusting for the age and SBP. The ROC curve showed that CAVI and age provided moderate diagnostic accuracy for BSS (area under the ROC curve (AUC for CAVI, 0.703, P<0.001; AUC for age, 0.692, P=0.001. The AUC of the “CAVI+Age,” which was calculated by combining CAVI with age, showed better accuracy (0.759, P<0.0001 than those of CAVI or age. The present study suggests that the CAVI combined with age can clinically serve as an objective tool to diagnose BSS in stroke patients.

  19. Data accuracy assessment using enterprise architecture

    Science.gov (United States)

    Närman, Per; Holm, Hannes; Johnson, Pontus; König, Johan; Chenine, Moustafa; Ekstedt, Mathias

    2011-02-01

    Errors in business processes result in poor data accuracy. This article proposes an architecture analysis method which utilises ArchiMate and the Probabilistic Relational Model formalism to model and analyse data accuracy. Since the resources available for architecture analysis are usually quite scarce, the method advocates interviews as the primary data collection technique. A case study demonstrates that the method yields correct data accuracy estimates and is more resource-efficient than a competing sampling-based data accuracy estimation method.

  20. Dipole model analysis of highest precision HERA data, including very low Q"2's

    International Nuclear Information System (INIS)

    Luszczak, A.; Kowalski, H.

    2016-12-01

    We analyse, within a dipole model, the final, inclusive HERA DIS cross section data in the low χ region, using fully correlated errors. We show, that these highest precision data are very well described within the dipole model framework starting from Q"2 values of 3.5 GeV"2 to the highest values of Q"2=250 GeV"2. To analyze the saturation effects we evaluated the data including also the very low 0.35< Q"2 GeV"2 region. The fits including this region show a preference of the saturation ansatz.

  1. CT coronary angiography: Influence of different cardiac reconstruction intervals on image quality and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Department of Radiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)], E-mail: marc.dewey@charite.de; Teige, Florian [Department of Radiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany); Rutsch, Wolfgang [Department of Cardiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)], E-mail: wolfgang.rutsch@charite.de; Schink, Tania [Department of Medical Biometry, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)], E-mail: peter.martus@charite.de; Hamm, Bernd [Department of Radiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)

    2008-07-15

    Purpose: To prospectively analyze image quality and diagnostic accuracy of different reconstruction intervals of coronary angiography using multislice computed tomography (MSCT). Materials and methods: For each of 47 patients, 10 ECG-gated MSCT reconstructions were generated throughout the RR interval from 0 to 90%, resulting in altogether 470 datasets. These datasets were randomly analyzed for image quality and accuracy and compared with conventional angiography. Statistical comparison of intervals was performed using nonparametric analysis for repeated measurements to account for clustering of arteries within patients. Results: Image reconstruction intervals centered at 80, 70, and 40% of the RR interval resulted (in that order) in the best overall image quality for all four main coronary vessels. Eighty percent reconstructions also yielded the highest diagnostic accuracy of all intervals. The combination of the three best intervals (80, 70, and 40%) significantly reduced the nondiagnostic rate as compared with 80% alone (p = 0.005). However, the optimal reconstruction interval combination achieved significantly improved specificities and nondiagnostic rates (p < 0.05). The optimal combination consisted of 1.7 {+-} 0.9 reconstruction intervals on average. In approximately half of the patients (49%, 23/47) a single reconstruction was optimal. In 18 (38%), 3 (6%), and 3 (6%) patients one, two, and three additional reconstruction intervals were required, respectively, to achieve optimal quality. In 28% of the patients the optimal combination consisted of reconstructions other than the three best intervals (80, 70, and 40%). Conclusion: Multiple image reconstruction intervals are essential to ensure high image quality and accuracy of CT coronary angiography.

  2. Is Assessment of Femoral Head Perfusion During Modified Dunn for Unstable Slipped Capital Femoral Epiphysis an Accurate Indicator of Osteonecrosis?

    Science.gov (United States)

    Novais, Eduardo N; Sink, Ernest L; Kestel, Lauryn A; Carry, Patrick M; Abdo, João C M; Heare, Travis C

    2016-08-01

    The modified Dunn procedure, which is an open subcapital realignment through a surgical dislocation approach, has gained popularity for the treatment of unstable slipped capital femoral epiphysis (SCFE). Intraoperative monitoring of the femoral head perfusion has been recommended as a method of predicting osteonecrosis; however, the accuracy of this assessment has not been well documented. We asked (1) whether intraoperative assessment of femoral head perfusion would help identify hips at risk of developing osteonecrosis; (2) whether one of the four methods of assessment of femoral head perfusion is more accurate (highest area under the curve) at identifying hips at risk of osteonecrosis; and (3) whether specific clinical features would be associated with osteonecrosis occurrence after a modified Dunn procedure for unstable SCFE. Between 2007 and 2014, we performed 29 modified Dunn procedures for unstable SCFE (16 boys, 11 girls; median age, 13 years; range, 8-17 years); two were lost to followup before 1 year. During this period, six patients with unstable SCFE were treated by other procedures. All patients undergoing modified Dunn underwent assessment of epiphyseal perfusion by the presence of active bleeding and/or by intracranial pressure (ICP) monitoring. In the initial five patients perfusion was recorded once, either before dissection of the retinacular flap or after fixation by one of the two methods. In the remaining 22 patients (81%), perfusion was systematically assessed before dissection of the retinacular flap and after fixation by both methods. Minimum followup was 1 year (median, 2.5 years; range, 1-8 years) because osteonecrosis typically develops within the first year after surgery. Patients were assessed for osteonecrosis by the presence of femoral head collapse at radiographs obtained every 3 months during the first year after surgery. Seven (26%) of the 27 patients developed osteonecrosis. Measures of diagnostic accuracy including sensitivity

  3. Influence of optic disc size on the diagnostic performance of macular ganglion cell complex and peripapillary retinal nerve fiber layer analyses in glaucoma

    Directory of Open Access Journals (Sweden)

    Cordeiro DV

    2011-09-01

    Full Text Available Daniela Valença Cordeiro1, Verônica Castro Lima1,2, Dinorah P Castro1,3, Leonardo C Castro1,3, Maria Angélica Pacheco2, Jae Min Lee2, Marcelo I Dimantas2, Tiago Santos Prata1,21Department of Ophthalmology, Federal University of São Paulo, São Paulo, 2Hospital Medicina dos Olhos, São Paulo, 3Centro Brasileiro de Especialidades Oftalmológicas, Araraquara, BrazilAim: To evaluate the influence of optic disc size on the diagnostic accuracy of macular ganglion cell complex (GCC and conventional peripapillary retinal nerve fiber layer (pRNFL analyses provided by spectral domain optical coherence tomography (SD-OCT in glaucoma.Methods: Eighty-two glaucoma patients and 30 healthy subjects were included. All patients underwent GCC (7 × 7 mm macular grid, consisting of RNFL, ganglion cell and inner plexiform layers and pRNFL thickness measurement (3.45 mm circular scan by SD-OCT. One eye was randomly selected for analysis. Initially, receiver operating characteristic (ROC curves were generated for different GCC and pRNFL parameters. The effect of disc area on the diagnostic accuracy of these parameters was evaluated using a logistic ROC regression model. Subsequently, 1.5, 2.0, and 2.5 mm2 disc sizes were arbitrarily chosen (based on data distribution and the predicted areas under the ROC curves (AUCs and sensitivities were compared at fixed specificities for each.Results: Average mean deviation index for glaucomatous eyes was -5.3 ± 5.2 dB. Similar AUCs were found for the best pRNFL (average thickness = 0.872 and GCC parameters (average thickness = 0.824; P = 0.19.The coefficient representing disc area in the ROC regression model was not statistically significant for average pRNFL thickness (-0.176 or average GCC thickness (0.088; P ≥ 0.56. AUCs for fixed disc areas (1.5, 2.0, and 2.5 mm2 were 0.904, 0.891, and 0.875 for average pRNFL thickness and 0.834, 0.842, and 0.851 for average GCC thickness, respectively. The highest sensitivities – at

  4. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients

    OpenAIRE

    Uemura, Mei

    2017-01-01

    Background: Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting h...

  5. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients

    OpenAIRE

    Mei Uemura; Yutaka Yano; Toshinari Suzuki; Taro Yasuma; Toshiyuki Sato; Aya Morimoto; Samiko Hosoya; Chihiro Suminaka; Hiromu Nakajima; Esteban C. Gabazza; Yoshiyuki Takei

    2017-01-01

    Background Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hy...

  6. Proposed hybrid-classifier ensemble algorithm to map snow cover area

    Science.gov (United States)

    Nijhawan, Rahul; Raman, Balasubramanian; Das, Josodhir

    2018-01-01

    Metaclassification ensemble approach is known to improve the prediction performance of snow-covered area. The methodology adopted in this case is based on neural network along with four state-of-art machine learning algorithms: support vector machine, artificial neural networks, spectral angle mapper, K-mean clustering, and a snow index: normalized difference snow index. An AdaBoost ensemble algorithm related to decision tree for snow-cover mapping is also proposed. According to available literature, these methods have been rarely used for snow-cover mapping. Employing the above techniques, a study was conducted for Raktavarn and Chaturangi Bamak glaciers, Uttarakhand, Himalaya using multispectral Landsat 7 ETM+ (enhanced thematic mapper) image. The study also compares the results with those obtained from statistical combination methods (majority rule and belief functions) and accuracies of individual classifiers. Accuracy assessment is performed by computing the quantity and allocation disagreement, analyzing statistic measures (accuracy, precision, specificity, AUC, and sensitivity) and receiver operating characteristic curves. A total of 225 combinations of parameters for individual classifiers were trained and tested on the dataset and results were compared with the proposed approach. It was observed that the proposed methodology produced the highest classification accuracy (95.21%), close to (94.01%) that was produced by the proposed AdaBoost ensemble algorithm. From the sets of observations, it was concluded that the ensemble of classifiers produced better results compared to individual classifiers.

  7. Accuracy of aging ducks in the U.S. Fish and Wildlife Service Waterfowl Parts Collection Survey

    Science.gov (United States)

    Pearse, Aaron T.; Johnson, Douglas H.; Richkus, Kenneth D.; Rohwer, Frank C.; Cox, Robert R.; Padding, Paul I.

    2014-01-01

    The U.S. Fish and Wildlife Service conducts an annual Waterfowl Parts Collection Survey to estimate composition of harvested waterfowl by species, sex, and age (i.e., juv or ad). The survey relies on interpretation of duck wings by a group of experienced biologists at annual meetings (hereafter, flyway wingbees). Our objectives were to estimate accuracy of age assignment at flyway wingbees and to explore how accuracy rates may influence bias of age composition estimates. We used banded mallards (Anas platyrhynchos; n = 791), wood ducks (Aix sponsa; n = 242), and blue-winged teal (Anas discors; n = 39) harvested and donated by hunters as our source of birds used in accuracy assessments. We sent wings of donated birds to wingbees after the 2002–2003 and 2003–2004 hunting seasons and compared species, sex, and age determinations made at wingbees with our assessments based on internal and external examination of birds and corresponding banding records. Determinations of species and sex of mallards, wood ducks, and blue-winged teal were accurate (>99%). Accuracy of aging adult mallards increased with harvest date, whereas accuracy of aging juvenile male wood ducks and juvenile blue-winged teal decreased with harvest date. Accuracy rates were highest (96% and 95%) for adult and juvenile mallards, moderate for adult and juvenile wood ducks (92% and 92%), and lowest for adult and juvenile blue-winged teal (84% and 82%). We used these estimates to calculate bias for all possible age compositions (0–100% proportion juv) and determined the range of age compositions estimated with acceptable levels of bias. Comparing these ranges with age compositions estimated from Parts Collection Surveys conducted from 1961 to 2008 revealed that mallard and wood duck age compositions were estimated with insignificant levels of bias in all national surveys. However, 69% of age compositions for blue-winged teal were estimated with an unacceptable level of bias. The low

  8. Improving shuffler assay accuracy

    International Nuclear Information System (INIS)

    Rinard, P.M.

    1995-01-01

    Drums of uranium waste should be disposed of in an economical and environmentally sound manner. The most accurate possible assays of the uranium masses in the drums are required for proper disposal. The accuracies of assays from a shuffler are affected by the type of matrix material in the drums. Non-hydrogenous matrices have little effect on neutron transport and accuracies are very good. If self-shielding is known to be a minor problem, good accuracies are also obtained with hydrogenous matrices when a polyethylene sleeve is placed around the drums. But for those cases where self-shielding may be a problem, matrices are hydrogenous, and uranium distributions are non-uniform throughout the drums, the accuracies are degraded. They can be greatly improved by determining the distributions of the uranium and then applying correction factors based on the distributions. This paper describes a technique for determining uranium distributions by using the neutron count rates in detector banks around the waste drum and solving a set of overdetermined linear equations. Other approaches were studied to determine the distributions and are described briefly. Implementation of this correction is anticipated on an existing shuffler next year

  9. Highest cited papers published in Neurology India: An analysis for the years 1993-2014.

    Science.gov (United States)

    Pandey, Paritosh; Subeikshanan, V; Madhugiri, Venkatesh S

    2016-01-01

    The highest cited papers published in a journal provide a snapshot of the clinical practice and research in that specialty and/or region. The aim of this study was to determine the highest cited papers published in Neurology India and analyze their attributes. This study was a citation analysis of all papers published in Neurology India since online archiving commenced in 1993. All papers published in Neurology India between the years 1993-2014 were listed. The number of times each paper had been cited up till the time of performing this study was determined by performing a Google Scholar search. Published papers were then ranked on the basis of total times cited since publication and the annual citation rate. Statistical Techniques: Simple counts and percentages were used to report most results. The mean citations received by papers in various categories were compared using the Student's t-test or a one-way analysis of variance, as appropriate. All analyses were carried out on SAS University Edition (SAS/STAT®, SAS Institute Inc, NC, USA) and graphs were generated on MS Excel 2016. The top papers on the total citations and annual citation rate rank lists pertained to basic neuroscience research. The highest cited paper overall had received 139 citations. About a quarter of the papers published had never been cited at all. The major themes represented were vascular diseases and infections. The highest cited papers reflect the diseases that are of major concern in India. Certain domains such as trauma, allied neurosciences, and basic neuroscience research were underrepresented.

  10. Measuring the Accuracy of Simple Evolving Connectionist System with Varying Distance Formulas

    Science.gov (United States)

    Al-Khowarizmi; Sitompul, O. S.; Suherman; Nababan, E. B.

    2017-12-01

    Simple Evolving Connectionist System (SECoS) is a minimal implementation of Evolving Connectionist Systems (ECoS) in artificial neural networks. The three-layer network architecture of the SECoS could be built based on the given input. In this study, the activation value for the SECoS learning process, which is commonly calculated using normalized Hamming distance, is also calculated using normalized Manhattan distance and normalized Euclidean distance in order to compare the smallest error value and best learning rate obtained. The accuracy of measurement resulted by the three distance formulas are calculated using mean absolute percentage error. In the training phase with several parameters, such as sensitivity threshold, error threshold, first learning rate, and second learning rate, it was found that normalized Euclidean distance is more accurate than both normalized Hamming distance and normalized Manhattan distance. In the case of beta fibrinogen gene -455 G/A polymorphism patients used as training data, the highest mean absolute percentage error value is obtained with normalized Manhattan distance compared to normalized Euclidean distance and normalized Hamming distance. However, the differences are very small that it can be concluded that the three distance formulas used in SECoS do not have a significant effect on the accuracy of the training results.

  11. The Highest Good and the Practical Regulative Knowledge in Kant’s Critique of Practical Reason

    OpenAIRE

    Joel Thiago Klein

    2016-01-01

    In this paper I defend three different points: first, that the concept of highest good is derived from an a priori but subjective argument, namely a maxim of pure practical reason; secondly, that the theory regarding the highest good has the validity of a practical regulative knowledge; and thirdly, that the practical regulative knowledge can be understood as the same “holding something to be true” as Kant attributes to hope and believe.

  12. Accuracy of apparent diffusion coefficient in differentiating pancreatic neuroendocrine tumour from intrapancreatic accessory spleen

    International Nuclear Information System (INIS)

    Pandey, Ankur; Pandey, Pallavi; Ghasabeh, Mounes Aliyari; Varzaneh, Farnaz Najmi; Khoshpouri, Pegah; Shao, Nannan; Pour, Manijeh Zargham; Fouladi, Daniel Fadaei; Kamel, Ihab R.; Hruban, Ralph H.; O'Broin-Lennon, Anne Marie

    2018-01-01

    To evaluate and compare the accuracy of absolute apparent diffusion coefficient (ADC) and normalised ADC (lesion-to-spleen ADC ratio) in differentiating pancreatic neuroendocrine tumour (NET) from intrapancreatic accessory spleen (IPAS). Study included 62 patients with the diagnosis of pancreatic NET (n=51) or IPAS (n=11). Two independent reviewers measured ADC on all lesions and spleen. Receiver operating characteristics (ROC) analysis to differentiate NET from IPAS was performed and compared for absolute and normalised ADC. Inter-reader reliability for the two methods was assessed. Pancreatic NET had significantly higher absolute ADC (1.431 x 10 -3 vs 0.967 x 10 -3 mm 2 /s; P<0.0001) and normalised ADC (1.59 vs 1.09; P<0.0001) compared to IPAS. An ADC value of ≥1.206 x 10 -3 mm 2 /s was 70.6% sensitive and 90.9% specific for the diagnosis of NET vs. IPAS. Lesion to spleen ADC ratio of ≥1.25 was 80.4% sensitive, and 81.8% specific while ratio of ≥1.29 was 74.5% sensitive and 100% specific in the differentiation. The area under the curve (AUCs) for two methods were similar (88.2% vs. 88.8%; P=0.899). Both methods demonstrated excellent inter-reader reliability with ICCs for absolute ADC and ADC ratio being 0.957 and 0.927, respectively. Both absolute and normalised ADC allow clinically relevant differentiation of pancreatic NET and IPAS. (orig.)

  13. Feasibility and Diagnostic Accuracy of Supersonic Shear-Wave Elastography for the Assessment of Liver Stiffness and Liver Fibrosis in Children: A Pilot Study of 96 Patients.

    Science.gov (United States)

    Franchi-Abella, Stéphanie; Corno, Lucie; Gonzales, Emmanuel; Antoni, Guillemette; Fabre, Monique; Ducot, Béatrice; Pariente, Danièle; Gennisson, Jean-Luc; Tanter, Mickael; Corréas, Jean-Michel

    2016-02-01

    To evaluate the feasibility of using supersonic shear-wave elastography (SSWE) in children and normal values of liver stiffness with the use of control patients of different ages (from neonates to teenagers) and the diagnostic accuracy of supersonic shear wave elastography for assessing liver fibrosis by using the histologic scoring system as the reference method in patients with liver disease, with a special concern for early stages of fibrosis. The institutional review board approved this prospective study. Informed consent was obtained from parents and children older than 7 years. First, 51 healthy children (from neonate to 15 years) were analyzed as the control group, and univariate and multivariate comparisons were performed to study the effect of age, transducer, breathing condition, probe, and position on elasticity values. Next, 45 children (from 1 month to 17.2 years old) who underwent liver biopsy were analyzed. SSWE measurements were obtained in the same region of the liver as the biopsy specimens. Biopsy specimens were reviewed in a blinded manner by a pathologist with the use of METAVIR criteria. The areas under the receiver operating characteristics curve (AUCs) were calculated for patients with fibrosis stage F0 versus those with stage F1-F2, F2 or higher, F3 or higher, and F4 or higher. A successful rate of SSWE measurement was 100% in 96 patients, including neonates. Liver stiffness values were significantly higher when an SC6-1 probe (Aixplorer; SuperSonic Imagine SA, Aix-enProvence, France) was used than when an SL15-4 probe (Aixplorer) was used (mean ± standard deviation, 6.94 kPa ± 1.42 vs 5.96 kPa ± 1.31; P = .006). There was no influence of sex, the location of measurement, or respiratory status on liver elasticity values (P = .41-.93), although the power to detect such a difference was low. According to the degree of liver fibrosis at liver biopsy, 88.5%-96.8% of patients were correctly classified, with AUCs of 0.90-0.98 (95% confidence

  14. The Best Prediction Model for Trauma Outcomes of the Current Korean Population: a Comparative Study of Three Injury Severity Scoring Systems

    Directory of Open Access Journals (Sweden)

    Kyoungwon Jung

    2016-08-01

    Full Text Available Background: Injury severity scoring systems that quantify and predict trauma outcomes have not been established in Korea. This study was designed to determine the best system for use in the Korean trauma population. Methods: We collected and analyzed the data from trauma patients admitted to our institution from January 2010 to December 2014. Injury Severity Score (ISS, Revised Trauma Score (RTS, and Trauma and Injury Severity Score (TRISS were calculated based on the data from the enrolled patients. Area under the receiver operating characteristic (ROC curve (AUC for the prediction ability of each scoring system was obtained, and a pairwise comparison of ROC curves was performed. Additionally, the cut-off values were estimated to predict mortality, and the corresponding accuracy, positive predictive value, and negative predictive value were obtained. Results: A total of 7,120 trauma patients (6,668 blunt and 452 penetrating injuries were enrolled in this study. The AUCs of ISS, RTS, and TRISS were 0.866, 0.894, and 0.942, respectively, and the prediction ability of the TRISS was significantly better than the others (p < 0.001, respectively. The cut-off value of the TRISS was 0.9082, with a sensitivity of 81.9% and specificity of 92.0%; mortality was predicted with an accuracy of 91.2%; its positive predictive value was the highest at 46.8%. Conclusions: The results of our study were based on the data from one institution and suggest that the TRISS is the best prediction model of trauma outcomes in the current Korean population. Further study is needed with more data from multiple centers in Korea.

  15. Which supplementary imaging modality should be used for breast ultrasonography? Comparison of the diagnostic performance of elastography and computer-aided diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Si Eun; Moon, Ji Eun Ho; Kim, Eun Kyung; Yoon, Jung Hyun [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    The aim of this study was to evaluate and compare the diagnostic performance of grayscale ultrasonography (US), US elastography, and US computer-aided diagnosis (US-CAD) in the differential diagnosis of breast masses. A total of 193 breast masses in 175 consecutive women (mean age, 46.4 years) from June to August 2015 were included. US and elastography images were obtained and recorded. A US-CAD system was applied to the grayscale sonograms, which were automatically analyzed and visualized in order to generate a final assessment. The final assessments of breast masses were based on the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) categories, while elasticity scores were assigned using a 5-point scoring system. The diagnostic performance of grayscale US, elastography, and US-CAD was calculated and compared. Of the 193 breast masses, 120 (62.2%) were benign and 73 (37.8%) were malignant. Breast masses had significantly higher rates of malignancy in BI-RADS categories 4c and 5, elastography patterns 4 and 5, and when the US-CAD assessment was possibly malignant (all P<0.001). Elastography had higher specificity (40.8%, P=0.042) than grayscale US. US-CAD showed the highest specificity (67.5%), positive predictive value (PPV) (61.4%), accuracy (74.1%), and area under the curve (AUC) (0.762, all P<0.05) among the three diagnostic tools. US-CAD had higher values for specificity, PPV, accuracy, and AUC than grayscale US or elastography. Computer-based analysis based on the morphologic features of US may be very useful in improving the diagnostic performance of breast US.

  16. Balancing dose and image registration accuracy for cone beam tomosynthesis (CBTS) for breast patient setup

    International Nuclear Information System (INIS)

    Winey, B. A.; Zygmanski, P.; Cormack, R. A.; Lyatskaya, Y.

    2010-01-01

    Purpose: To balance dose reduction and image registration accuracy in breast setup imaging. In particular, the authors demonstrate the relationship between scan angle and dose delivery for cone beam tomosynthesis (CBTS) when employed for setup verification of breast cancer patients with surgical clips. Methods: The dose measurements were performed in a female torso phantom for varying scan angles of CBTS. Setup accuracy was measured using three registration methods: Clip centroid localization accuracy and the accuracy of two semiautomatic registration algorithms. The dose to the organs outside of the ipsilateral breast and registration accuracy information were compared to determine the optimal scan angle for CBTS for breast patient setup verification. Isocenter positions at the center of the patient and at the breast-chest wall interface were considered. Results: Image registration accuracy was within 1 mm for the CBTS scan angles θ above 20 deg. for some scenarios and as large as 80 deg. for the worst case, depending on the imaged breast and registration algorithm. Registration accuracy was highest based on clip centroid localization. For left and right breast imaging with the isocenter at the chest wall, the dose to the contralateral side of the patient was very low (<0.5 cGy) for all scan angles considered. For central isocenter location, the optimal scan angles were 30 deg. - 50 deg. for the left breast imaging and 40 deg. - 50 deg. for the right breast imaging, with the difference due to the geometric asymmetry of the current clinical imaging system. Conclusions: The optimal scan angles for CBTS imaging were found to be between 10 deg. and 50 deg., depending on the isocenter location and ipsilateral breast. Use of the isocenter at the breast-chest wall locations always resulted in greater accuracy of image registration (<1 mm) at smaller angles (10 deg. - 20 deg.) and at lower doses (<0.1 cGy) to the contralateral organs. For chest wall isocenters, doses

  17. Effect of species rarity on the accuracy of species distribution models for reptiles and amphibians in southern California

    Science.gov (United States)

    Franklin, J.; Wejnert, K.E.; Hathaway, S.A.; Rochester, C.J.; Fisher, R.N.

    2009-01-01

    Aim: Several studies have found that more accurate predictive models of species' occurrences can be developed for rarer species; however, one recent study found the relationship between range size and model performance to be an artefact of sample prevalence, that is, the proportion of presence versus absence observations in the data used to train the model. We examined the effect of model type, species rarity class, species' survey frequency, detectability and manipulated sample prevalence on the accuracy of distribution models developed for 30 reptile and amphibian species. Location: Coastal southern California, USA. Methods: Classification trees, generalized additive models and generalized linear models were developed using species presence and absence data from 420 locations. Model performance was measured using sensitivity, specificity and the area under the curve (AUC) of the receiver-operating characteristic (ROC) plot based on twofold cross-validation, or on bootstrapping. Predictors included climate, terrain, soil and vegetation variables. Species were assigned to rarity classes by experts. The data were sampled to generate subsets with varying ratios of presences and absences to test for the effect of sample prevalence. Join count statistics were used to characterize spatial dependence in the prediction errors. Results: Species in classes with higher rarity were more accurately predicted than common species, and this effect was independent of sample prevalence. Although positive spatial autocorrelation remained in the prediction errors, it was weaker than was observed in the species occurrence data. The differences in accuracy among model types were slight. Main conclusions: Using a variety of modelling methods, more accurate species distribution models were developed for rarer than for more common species. This was presumably because it is difficult to discriminate suitable from unsuitable habitat for habitat generalists, and not as an artefact of the

  18. Geoid undulation accuracy

    Science.gov (United States)

    Rapp, Richard H.

    1993-01-01

    The determination of the geoid and equipotential surface of the Earth's gravity field, has long been of interest to geodesists and oceanographers. The geoid provides a surface to which the actual ocean surface can be compared with the differences implying information on the circulation patterns of the oceans. For use in oceanographic applications the geoid is ideally needed to a high accuracy and to a high resolution. There are applications that require geoid undulation information to an accuracy of +/- 10 cm with a resolution of 50 km. We are far from this goal today but substantial improvement in geoid determination has been made. In 1979 the cumulative geoid undulation error to spherical harmonic degree 20 was +/- 1.4 m for the GEM10 potential coefficient model. Today the corresponding value has been reduced to +/- 25 cm for GEM-T3 or +/- 11 cm for the OSU91A model. Similar improvements are noted by harmonic degree (wave-length) and in resolution. Potential coefficient models now exist to degree 360 based on a combination of data types. This paper discusses the accuracy changes that have taken place in the past 12 years in the determination of geoid undulations.

  19. [The gender gap in highest quality medical research - A scientometric analysis of the representation of female authors in highest impact medical journals].

    Science.gov (United States)

    Bendels, Michael H K; Wanke, Eileen M; Benik, Steffen; Schehadat, Marc S; Schöffel, Norman; Bauer, Jan; Gerber, Alexander; Brüggmann, Dörthe; Oremek, Gerhard M; Groneberg, David A

    2018-05-01

     The study aims to elucidate the state of gender equality in high-impact medical research, analyzing the representation of female authorships from January, 2008 to September, 2017.  133 893 male and female authorships from seven high-impact medical journals were analyzed. The key methodology was the combined analysis of the relative frequency, odds ratio and citations of female authorships. The Prestige Index measures the distribution of prestigious authorships between the two genders.  35.0 % of all authorships and 34.3 % of the first, 36.1 % of the co- and 24.2 % of the last authorships were held by women. Female authors have an odds ratio of 0.97 (KI: 0.93 - 1.01) for first, 1.36 (KI: 1.32 - 1.40) for co- und 0.57 (KI: 0.54 - 0.60) for last authorships compared to male authors. The proportion of female authorships exhibits an annual growth of 1.3 % overall, with 0.5 % for first, 1.2 % for co-, and 0.8 % for last authorships. Women are underrepresented at prestigious authorship compared to men (Prestige Index = -0.38). The underrepresentation accentuates in highly competitive articles attracting the highest citation rates, namely, articles with many authors and articles that were published in highest-impact journals. Multi-author articles with male key authors are more frequently cited than articles with female key authors. The gender-specific differences in citation rates increase the more authors contribute to an article. Women publish fewer articles compared to men (39.6 % female authors are responsible for 35.0 % of the authorships) and are underrepresented at productivity levels of more than 1 article per author. Distinct differences at the country level were revealed.  High impact medical research is characterized by few female group leaders as last authors and many female researchers being first or co-authors early in their career. It is very likely that this gender-specific career dichotomy will persistent in

  20. Automatic orbital GTAW welding: Highest quality welds for tomorrow's high-performance systems

    Science.gov (United States)

    Henon, B. K.

    1985-01-01

    Automatic orbital gas tungsten arc welding (GTAW) or TIG welding is certain to play an increasingly prominent role in tomorrow's technology. The welds are of the highest quality and the repeatability of automatic weldings is vastly superior to that of manual welding. Since less heat is applied to the weld during automatic welding than manual welding, there is less change in the metallurgical properties of the parent material. The possibility of accurate control and the cleanliness of the automatic GTAW welding process make it highly suitable to the welding of the more exotic and expensive materials which are now widely used in the aerospace and hydrospace industries. Titanium, stainless steel, Inconel, and Incoloy, as well as, aluminum can all be welded to the highest quality specifications automatically. Automatic orbital GTAW equipment is available for the fusion butt welding of tube-to-tube, as well as, tube to autobuttweld fittings. The same equipment can also be used for the fusion butt welding of up to 6 inch pipe with a wall thickness of up to 0.154 inches.

  1. Evaluation of reduced-dose CT for acute non-traumatic abdominal pain: evaluation of diagnostic accuracy in comparison to standard-dose CT.

    Science.gov (United States)

    Othman, Ahmed E; Bongers, Malte Niklas; Zinsser, Dominik; Schabel, Christoph; Wichmann, Julian L; Arshid, Rami; Notohamiprodjo, Mike; Nikolaou, Konstantin; Bamberg, Fabian

    2018-01-01

    Background Patients with acute non-traumatic abdominal pain often undergo abdominal computed tomography (CT). However, abdominal CT is associated with high radiation exposure. Purpose To evaluate diagnostic performance of a reduced-dose 100 kVp CT protocol with advanced modeled iterative reconstruction as compared to a linearly blended 120 kVp protocol for assessment of acute, non-traumatic abdominal pain. Material and Methods Two radiologists assessed 100 kVp and linearly blended 120 kVp series of 112 consecutive patients with acute non-traumatic pain (onset diagnostic confidence. Both 100 kVp and linearly blended 120 kVp series were quantitatively evaluated regarding radiation dose and image noise. Comparative statistics and diagnostic accuracy was calculated using receiver operating curve (ROC) statistics, with final clinical diagnosis/clinical follow-up as reference standard. Results Image quality was high for both series without detectable significant differences ( P = 0.157). Image noise and artifacts were rated low for both series but significantly higher for 100 kVp ( P ≤ 0.021). Diagnostic accuracy was high for both series (120 kVp: area under the curve [AUC] = 0.950, sensitivity = 0.958, specificity = 0.941; 100 kVp: AUC ≥ 0.910, sensitivity ≥ 0.937, specificity = 0.882; P ≥ 0.516) with almost perfect inter-rater agreement (Kappa = 0.939). Diagnostic confidence was high for both dose levels without significant differences (100 kVp 5, range 4-5; 120 kVp 5, range 3-5; P = 0.134). The 100 kVp series yielded 26.1% lower radiation dose compared with the 120 kVp series (5.72 ± 2.23 mSv versus 7.75 ± 3.02 mSv, P diagnostic accuracy for the assessment of acute non-traumatic abdominal pain.

  2. Accuracy of Stated Energy Contents of Restaurant Foods

    Science.gov (United States)

    Urban, Lorien E.; McCrory, Megan A.; Dallal, Gerard E.; Das, Sai Krupa; Saltzman, Edward; Weber, Judith L.; Roberts, Susan B.

    2015-01-01

    Context National recommendations for the prevention and treatment of obesity emphasize reducing energy intake. Foods purchased in restaurants provide approximately 35% of the daily energy intake in US individuals but the accuracy of the energy contents listed for these foods is unknown. Objective To examine the accuracy of stated energy contents of foods purchased in restaurants. Design and Setting A validated bomb calorimetry technique was used to measure dietary energy in food from 42 restaurants, comprising 269 total food items and 242 unique foods. The restaurants and foods were randomly selected from quick-serve and sit-down restaurants in Massachusetts, Arkansas, and Indiana between January and June 2010. Main Outcome Measure The difference between restaurant-stated and laboratory-measured energy contents, which were corrected for standard metabolizable energy conversion factors. Results The absolute stated energy contents were not significantly different from the absolute measured energy contents overall (difference of 10 kcal/portion; 95% confidence interval [CI], −15 to 34 kcal/portion; P=.52); however, the stated energy contents of individual foods were variable relative to the measured energy contents. Of the 269 food items, 50 (19%) contained measured energy contents of at least 100 kcal/portion more than the stated energy contents. Of the 10% of foods with the highest excess energy in the initial sampling, 13 of 17 were available for a second sampling. In the first analysis, these foods contained average measured energy contents of 289 kcal/portion (95% CI, 186 to 392 kcal/portion) more than the stated energy contents; in the second analysis, these foods contained average measured energy contents of 258 kcal/portion (95% CI, 154 to 361 kcal/portion) more than the stated energy contents (Prestaurant foods were accurate overall. However, there was substantial inaccuracy for some individual foods, with understated energy contents for those with lower

  3. Test expectancy affects metacomprehension accuracy.

    Science.gov (United States)

    Thiede, Keith W; Wiley, Jennifer; Griffin, Thomas D

    2011-06-01

    Theory suggests that the accuracy of metacognitive monitoring is affected by the cues used to judge learning. Researchers have improved monitoring accuracy by directing attention to more appropriate cues; however, this is the first study to more directly point students to more appropriate cues using instructions regarding tests and practice tests. The purpose of the present study was to examine whether the accuracy metacognitive monitoring was affected by the nature of the test expected. Students (N= 59) were randomly assigned to one of two test expectancy groups (memory vs. inference). Then after reading texts, judging learning, completed both memory and inference tests. Test performance and monitoring accuracy were superior when students received the kind of test they had been led to expect rather than the unexpected test. Tests influence students' perceptions of what constitutes learning. Our findings suggest that this could affect how students prepare for tests and how they monitoring their own learning. ©2010 The British Psychological Society.

  4. Quantitative forecasting of PTSD from early trauma responses: a Machine Learning application.

    Science.gov (United States)

    Galatzer-Levy, Isaac R; Karstoft, Karen-Inge; Statnikov, Alexander; Shalev, Arieh Y

    2014-12-01

    There is broad interest in predicting the clinical course of mental disorders from early, multimodal clinical and biological information. Current computational models, however, constitute a significant barrier to realizing this goal. The early identification of trauma survivors at risk of post-traumatic stress disorder (PTSD) is plausible given the disorder's salient onset and the abundance of putative biological and clinical risk indicators. This work evaluates the ability of Machine Learning (ML) forecasting approaches to identify and integrate a panel of unique predictive characteristics and determine their accuracy in forecasting non-remitting PTSD from information collected within 10 days of a traumatic event. Data on event characteristics, emergency department observations, and early symptoms were collected in 957 trauma survivors, followed for fifteen months. An ML feature selection algorithm identified a set of predictors that rendered all others redundant. Support Vector Machines (SVMs) as well as other ML classification algorithms were used to evaluate the forecasting accuracy of i) ML selected features, ii) all available features without selection, and iii) Acute Stress Disorder (ASD) symptoms alone. SVM also compared the prediction of a) PTSD diagnostic status at 15 months to b) posterior probability of membership in an empirically derived non-remitting PTSD symptom trajectory. Results are expressed as mean Area Under Receiver Operating Characteristics Curve (AUC). The feature selection algorithm identified 16 predictors, present in ≥ 95% cross-validation trials. The accuracy of predicting non-remitting PTSD from that set (AUC = .77) did not differ from predicting from all available information (AUC = .78). Predicting from ASD symptoms was not better then chance (AUC = .60). The prediction of PTSD status was less accurate than that of membership in a non-remitting trajectory (AUC = .71). ML methods may fill a critical gap in forecasting PTSD. The

  5. Modeling Pathologic Response of Esophageal Cancer to Chemoradiation Therapy Using Spatial-Temporal 18F-FDG PET Features, Clinical Parameters, and Demographics

    International Nuclear Information System (INIS)

    Zhang, Hao; Tan, Shan; Chen, Wengen; Kligerman, Seth; Kim, Grace; D'Souza, Warren D.; Suntharalingam, Mohan; Lu, Wei

    2014-01-01

    Purpose: To construct predictive models using comprehensive tumor features for the evaluation of tumor response to neoadjuvant chemoradiation therapy (CRT) in patients with esophageal cancer. Methods and Materials: This study included 20 patients who underwent trimodality therapy (CRT + surgery) and underwent 18 F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) both before and after CRT. Four groups of tumor features were examined: (1) conventional PET/CT response measures (eg, standardized uptake value [SUV] max , tumor diameter); (2) clinical parameters (eg, TNM stage, histology) and demographics; (3) spatial-temporal PET features, which characterize tumor SUV intensity distribution, spatial patterns, geometry, and associated changes resulting from CRT; and (4) all features combined. An optimal feature set was identified with recursive feature selection and cross-validations. Support vector machine (SVM) and logistic regression (LR) models were constructed for prediction of pathologic tumor response to CRT, cross-validations being used to avoid model overfitting. Prediction accuracy was assessed by area under the receiver operating characteristic curve (AUC), and precision was evaluated by confidence intervals (CIs) of AUC. Results: When applied to the 4 groups of tumor features, the LR model achieved AUCs (95% CI) of 0.57 (0.10), 0.73 (0.07), 0.90 (0.06), and 0.90 (0.06). The SVM model achieved AUCs (95% CI) of 0.56 (0.07), 0.60 (0.06), 0.94 (0.02), and 1.00 (no misclassifications). With the use of spatial-temporal PET features combined with conventional PET/CT measures and clinical parameters, the SVM model achieved very high accuracy (AUC 1.00) and precision (no misclassifications)—results that were significantly better than when conventional PET/CT measures or clinical parameters and demographics alone were used. For groups with many tumor features (groups 3 and 4), the SVM model achieved significantly higher accuracy than

  6. Lung malignancy: Diagnostic accuracies of bronchoalveolar lavage, bronchial brushing, and fine needle aspiration cytology

    Science.gov (United States)

    Sareen, Rateesh; Pandey, C L

    2016-01-01

    Background: Early diagnosis of lung cancer plays a pivotal role in reducing lung cancer death rate. Cytological techniques are safer, economical and provide quick results. Bronchoscopic washing, brushing and fine needle aspirations not only complement tissue biopsies in the diagnosis of lung cancer but also comparable. Objectives: (1) To find out diagnostic yields of bronchioalveolar lavage, bronchial brushings, FNAC in diagnosis of lung malignancy. (2) To compare relative accuracy of these three cytological techniques. (3) To correlate the cytologic diagnosis with clinical, bronchoscopic and CT findings. (4) Cytological and histopathological correlation of lung lesions. Methods: All the patients who came with clinical or radiological suspicion of lung malignancy in two and a half year period were included in study. Bronchoalveolar lavage was the most common type of cytological specimen (82.36%), followed by CT guided FNAC (9.45%) and bronchial brushings (8.19%). Sensitivity, specificity, positive and negative predictive value for all techniques and correlation with histopathology was done using standard formulas. Results: The most sensitive technique was CT FNAC – (87.25%) followed by brushings (77.78%) and BAL (72.69%). CT FNAC had highest diagnostic yield (90.38%), followed by brushings (86.67%) and BAL (83.67%). Specificity and positive predictive value were 100 % each of all techniques. Lowest false negatives were obtained in CT FNAC (12.5%) and highest in BAL (27.3%). Highest negative predictive value was of BAL 76.95 % followed by BB 75.59% and CT FNAC 70.59%. Conclusion: Before administering antitubercular treatment every effort should be made to rule out malignancy. CT FNAC had highest diagnostic yield among three cytological techniques. BAL is an important tool in screening central as well as in accessible lesions. It can be used at places where CT guided FNAC is not available or could not be done due to technical or financial limitations PMID:27890992

  7. [Study of personal best value of peak expiratory flow in patients with asthma--comparison of the highest value of daily PEF under good control and the highest value of daily PEF obtained after using repeated inhaled beta2-agonist during high-dose inhaled steroid treatment].

    Science.gov (United States)

    Watanabe, Naoto; Makino, Sohei; Kihara, Norio; Fukuda, Takeshi

    2008-12-01

    In the guideline for asthma management, it is important to find the personal best value of peak expiratory flow (best PEF). Recently, we have substituted the highest value of PEF in daily life under good control (daily highest PEF) for the best PEF. In the present study, we considered whether the daily highest PEF could be used as the best PEF or not. Subjects were 30 asthmatics who were well controlled but whose baseline PEF values were less than 80 percent of predicted values. We compared the daily highest PEF and the highest of PEF obtained after repeated inhaled beta2-agonist (salbutamol MDI every 20 minutes three times). All subjects then received 1600 microg/day of beclomethasone dipropionate (BDP) for 4 to 8 weeks. We studied the effect of high-dose inhaled steroid treatment on each PEF value and compared the daily highest PEF and the highest PEF obtained after using repeated salbutamol MDI during high dose inhaled steroid therapy on the examination day again. The baseline PEF, daily highest PEF and the highest PEF obtained after salbutamol MDI were significantly less than the each values obtained after high-dose BDP. The best PEF value of them was the value obtained after repeated salbutamol MDI during high dose BDP. We suggest that the daily highest PEF under good control is not a substitute for best PEF because it changes according to the degree of improvement of airway inflammation. We recommend that a course of high dose inhaled steroid is effective in finding the best value of PEF for each individual with moderate asthma.

  8. Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse Cohort.

    Science.gov (United States)

    Shcherbina, Anna; Mattsson, C Mikael; Waggott, Daryl; Salisbury, Heidi; Christle, Jeffrey W; Hastie, Trevor; Wheeler, Matthew T; Ashley, Euan A

    2017-05-24

    The ability to measure physical activity through wrist-worn devices provides an opportunity for cardiovascular medicine. However, the accuracy of commercial devices is largely unknown. The aim of this work is to assess the accuracy of seven commercially available wrist-worn devices in estimating heart rate (HR) and energy expenditure (EE) and to propose a wearable sensor evaluation framework. We evaluated the Apple Watch, Basis Peak, Fitbit Surge, Microsoft Band, Mio Alpha 2, PulseOn, and Samsung Gear S2. Participants wore devices while being simultaneously assessed with continuous telemetry and indirect calorimetry while sitting, walking, running, and cycling. Sixty volunteers (29 male, 31 female, age 38 ± 11 years) of diverse age, height, weight, skin tone, and fitness level were selected. Error in HR and EE was computed for each subject/device/activity combination. Devices reported the lowest error for cycling and the highest for walking. Device error was higher for males, greater body mass index, darker skin tone, and walking. Six of the devices achieved a median error for HR below 5% during cycling. No device achieved an error in EE below 20 percent. The Apple Watch achieved the lowest overall error in both HR and EE, while the Samsung Gear S2 reported the highest. In conclusion, most wrist-worn devices adequately measure HR in laboratory-based activities, but poorly estimate EE, suggesting caution in the use of EE measurements as part of health improvement programs. We propose reference standards for the validation of consumer health devices (http://precision.stanford.edu/).

  9. Test Expectancy Affects Metacomprehension Accuracy

    Science.gov (United States)

    Thiede, Keith W.; Wiley, Jennifer; Griffin, Thomas D.

    2011-01-01

    Background: Theory suggests that the accuracy of metacognitive monitoring is affected by the cues used to judge learning. Researchers have improved monitoring accuracy by directing attention to more appropriate cues; however, this is the first study to more directly point students to more appropriate cues using instructions regarding tests and…

  10. Detection of lymph node metastases in head and neck cancer: A meta-analysis comparing US, USgFNAC, CT and MR imaging

    International Nuclear Information System (INIS)

    Bondt, R.B.J. de; Nelemans, P.J.; Hofman, P.A.M.; Casselman, J.W.; Kremer, B.; Engelshoven, J.M.A. van; Beets-Tan, R.G.H.

    2007-01-01

    Purpose: To perform a meta-analysis comparing ultrasonography (US), US guided fine needle aspiration cytology (USgFNAC), computed tomography (CT), and magnetic resonance imaging (MRI) in the detection of lymph node metastases in head and neck cancer. Methods: MEDLINE, EMBASE and Cochrane databases were searched (January 1990-January 2006) for studies reporting diagnostic performances of US, USgFNAC, CT, and MRI to detect cervical lymph node metastases. Two reviewers screened text and reference lists of potentially eligible articles. Criteria for study inclusion: (1) histopathology was the reference standard, (2) primary tumors and metastases were squamous cell carcinoma and (3) data were available to construct 2 x 2 contingency tables. Meta-analysis of pairs of sensitivity and specificity was performed using bivariate analysis. Summary estimates for diagnostic performance used were sensitivity, specificity, diagnostic odds ratios (DOR) (95% confidence intervals) and summary receiver operating characteristics (SROC) curves. Results: From seventeen articles, 25 data sets could be retrieved. Eleven articles studied one modality: US (n = 4); USgFNAC (n = 1); CT (n = 3); MRI (n = 3). Six articles studied two or more modalities: US and CT (n = 2); USgFNAC and CT (n = 1); CT and MRI (n = 1); MRI and MRI-USPIO (Sinerem) (n = 2); US, USgFNAC, CT and MRI (n = 1). USgFNAC (AUC = 0.98) and US (AUC = 0.95) showed the highest areas under the curve (AUC). MRI-USPIO (AUC = 0.89) and CT (AUC = 0.88) had similar results. MRI showed an AUC = 0.79. USgFNAC showed the highest DOR (DOR = 260) compared to US (DOR = 40), MRI-USPIO (DOR = 21), CT (DOR = 14) and MRI (DOR = 7). Conclusion USgFNAC showed to be the most accurate imaging modality to detect cervical lymph node metastases

  11. The acute impact of the intake of four types of bread on satiety and blood concentrations of glucose, insulin, free fatty acids, triglyceride and acylated ghrelin. A randomized controlled cross-over trial.

    Science.gov (United States)

    Bo, S; Seletto, M; Choc, A; Ponzo, V; Lezo, A; Demagistris, A; Evangelista, A; Ciccone, G; Bertolino, M; Cassader, M; Gambino, R

    2017-02-01

    The purpose of the present study is to compare the effects of four different breads (one commercial par-baked wheat bread, three sourdough breads prepared with commercial wheat flour, organic wheat flour, organic einkorn flour) in 16 healthy subjects. The primary outcome of this randomized cross-over trial was evaluating intra-individual changes in glycemic areas-under-the-curve (AUCs) after 50g carbohydrate portions of each bread; secondary outcomes were changes in insulin, fatty free acids (FFA), triglyceride, acylated ghrelin and satiety AUCs. Blood samples and satiety ratings were collected every 30-min for 2-h after the consumption of each bread. The einkorn flour showed the lowest amylase activity, the commercial flour the highest; commercial bread had the highest carbohydrate content and the lowest dietary fiber content. Glucose AUCs were significantly lower after the consumption of sourdough breads made with organic (12,754±1433mg/dL×h) and einkorn flour (12,216±1210mg/dL×h), with respect to the commercial bread (13,849±2193mg/dL×h). Insulin AUCs decreased after the consumption of all sourdough breads when compared to commercial bread. FFA and triglyceride AUCs did not differ by kind of breads. Median ghrelin AUC was significantly lower and satiety higher after the einkorn bread (3710pg/mL×h; 3225±2414, respectively) than after commercial bread consumption (4140pg/mL×h; 1706±1766, respectively), but not with other sourdough breads. In conclusion, the use of sourdough may improve the nutritional features of breads; einkorn bread induced the least disturbance in carbohydrate homeostasis and the greater satiety. If confirmed by further research, these results might have implications in the approach towards chronic dysmetabolic diseases. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Dynamic contrast-enhanced case-control analysis in 3T MRI of prostate cancer can help to characterize tumor aggressiveness

    Energy Technology Data Exchange (ETDEWEB)

    Sanz-Requena, Roberto, E-mail: roberto.sanz@quironsalud.es [Biomedical Engineering, Hospital Quirónsalud Valencia, Valencia (Spain); Radiology Department, Hospital Quirónsalud Valencia, Valencia (Spain); GIBI230, Instituto de Investigación Sanitaria y Hospital Universitari i Politècnic La Fe, Valencia (Spain); Martí-Bonmatí, Luis [Radiology Department, Hospital Quirónsalud Valencia, Valencia (Spain); GIBI230, Instituto de Investigación Sanitaria y Hospital Universitari i Politècnic La Fe, Valencia (Spain); Pérez-Martínez, Rosario [Radiology Department, Hospital Quirónsalud Valencia, Valencia (Spain); García-Martí, Gracián [Biomedical Engineering, Hospital Quirónsalud Valencia, Valencia (Spain); Radiology Department, Hospital Quirónsalud Valencia, Valencia (Spain); GIBI230, Instituto de Investigación Sanitaria y Hospital Universitari i Politècnic La Fe, Valencia (Spain); CIBER-SAM, Instituto de Salud Carlos III, Madrid (Spain)

    2016-11-15

    Highlights: • Curve types showed no statistical association with healthy/tumor peripheral areas. • K{sup trans}, v{sub e}, upslope and AUC showed significant differences in controls vs. tumors. • The global diagnostic performance of standard MRI perfusion parameters is poor. • Normalized K{sup trans}, upslope and AUC had good diagnostic accuracy for tumor grading. - Abstract: Purpose: The aim of this work is to establish normality and tumor tissue ranges for perfusion parameters from dynamic contrast-enhanced (DCE) MR of the peripheral prostate at 3T and to compare the diagnostic performance of quantitative and semi-quantitative parameters. Materials and methods: Thirty-six patients with prostate carcinomas (18 Gleason-6, 15 Gleason-7, and 3 Gleason-8) and 33 healthy subjects were included. Image analysis workflow comprised four steps: manual segmentation of whole prostate and lesions, series registration, voxelwise T1 mapping and calculation of pharmacokinetic and semi-quantitative parameters. Results: K{sup trans}, v{sub e}, upslope and AUC60 showed statistically significant differences between healthy peripheral areas and tumors. Curve type showed no association with healthy/tumor peripheral areas (chi-square = 0.702). Areas under the ROC curves were 0.64 (95% CI: 0.54–0.75), 0.70 (0.60–0.80), 0.62 (0.51–0.72) and 0.63 (0.52–0.74) for K{sup trans}, v{sub e}, upslope and AUC60, respectively. The optimal cutoff values were: K{sup trans} = 0.21 min{sup −1} (sensitivity = 0.61, specificity = 0.64), v{sub e} = 0.36 (0.63, 0.71), upslope = 0.59 (0.59, 0.59) and AUC60 = 2.4 (0.63, 0.64). Significant differences were found between Gleason scores 6 and 7 for normalized K{sup trans}, upslope and AUC60, with good diagnostic accuracy (area under ROC curve 0.80, 95% CI: 0.60–1.00). Conclusion: Quantitative (K{sup trans} and v{sub e}) and semi-quantitative (upslope and AUC60) perfusion parameters showed significant differences between tumors and control

  13. SU-D-204-05: Fitting Four NTCP Models to Treatment Outcome Data of Salivary Glands Recorded Six Months After Radiation Therapy for Head and Neck Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Mavroidis, P; Price, A; Kostich, M; Green, R; Das, S; Marks, L; Chera, B [University North Carolina, Chapel Hill, NC (United States); Amdur, R; Mendenhall, W [University of Florida, Gainesville, FL (United States); Sheets, N [University of North Carolina, Raleigh, NC (United States)

    2016-06-15

    Purpose: To estimate the radiobiological parameters of four popular NTCP models that describe the dose-response relations of salivary glands to the severity of patient reported dry mouth 6 months post chemo-radiotherapy. To identify the glands, which best correlate with the manifestation of those clinical endpoints. Finally, to evaluate the goodness-of-fit of the NTCP models. Methods: Forty-three patients were treated on a prospective multiinstitutional phase II study for oropharyngeal squamous cell carcinoma. All the patients received 60 Gy IMRT and they reported symptoms using the novel patient reported outcome version of the CTCAE. We derived the individual patient dosimetric data of the parotid and submandibular glands (SMG) as separate structures as well as combinations. The Lyman-Kutcher-Burman (LKB), Relative Seriality (RS), Logit and Relative Logit (RL) NTCP models were used to fit the patients data. The fitting of the different models was assessed through the area under the receiver operating characteristic curve (AUC) and the Odds Ratio methods. Results: The AUC values were highest for the contralateral parotid for Grade ≥ 2 (0.762 for the LKB, RS, Logit and 0.753 for the RL). For the salivary glands the AUC values were: 0.725 for the LKB, RS, Logit and 0.721 for the RL. For the contralateral SMG the AUC values were: 0.721 for LKB, 0.714 for Logit and 0.712 for RS and RL. The Odds Ratio for the contralateral parotid was 5.8 (1.3–25.5) for all the four NTCP models for the radiobiological dose threshold of 21Gy. Conclusion: It was shown that all the examined NTCP models could fit the clinical data well with very similar accuracy. The contralateral parotid gland appears to correlated best with the clinical endpoints of severe/very severe dry mouth. An EQD2Gy dose of 21Gy appears to be a safe threshold to be used as a constraint in treatment planning.

  14. Genotype-driven identification of a molecular network predictive of advanced coronary calcium in ClinSeq® and Framingham Heart Study cohorts.

    Science.gov (United States)

    Oguz, Cihan; Sen, Shurjo K; Davis, Adam R; Fu, Yi-Ping; O'Donnell, Christopher J; Gibbons, Gary H

    2017-10-26

    One goal of personalized medicine is leveraging the emerging tools of data science to guide medical decision-making. Achieving this using disparate data sources is most daunting for polygenic traits. To this end, we employed random forests (RFs) and neural networks (NNs) for predictive modeling of coronary artery calcium (CAC), which is an intermediate endo-phenotype of coronary artery disease (CAD). Model inputs were derived from advanced cases in the ClinSeq®; discovery cohort (n=16) and the FHS replication cohort (n=36) from 89 th -99 th CAC score percentile range, and age-matched controls (ClinSeq®; n=16, FHS n=36) with no detectable CAC (all subjects were Caucasian males). These inputs included clinical variables and genotypes of 56 single nucleotide polymorphisms (SNPs) ranked highest in terms of their nominal correlation with the advanced CAC state in the discovery cohort. Predictive performance was assessed by computing the areas under receiver operating characteristic curves (ROC-AUC). RF models trained and tested with clinical variables generated ROC-AUC values of 0.69 and 0.61 in the discovery and replication cohorts, respectively. In contrast, in both cohorts, the set of SNPs derived from the discovery cohort were highly predictive (ROC-AUC ≥0.85) with no significant change in predictive performance upon integration of clinical and genotype variables. Using the 21 SNPs that produced optimal predictive performance in both cohorts, we developed NN models trained with ClinSeq®; data and tested with FHS data and obtained high predictive accuracy (ROC-AUC=0.80-0.85) with several topologies. Several CAD and "vascular aging" related biological processes were enriched in the network of genes constructed from the predictive SNPs. We identified a molecular network predictive of advanced coronary calcium using genotype data from ClinSeq®; and FHS cohorts. Our results illustrate that machine learning tools, which utilize complex interactions between disease

  15. Detecting epileptic seizure with different feature extracting strategies using robust machine learning classification techniques by applying advance parameter optimization approach.

    Science.gov (United States)

    Hussain, Lal

    2018-06-01

    Epilepsy is a neurological disorder produced due to abnormal excitability of neurons in the brain. The research reveals that brain activity is monitored through electroencephalogram (EEG) of patients suffered from seizure to detect the epileptic seizure. The performance of EEG detection based epilepsy require feature extracting strategies. In this research, we have extracted varying features extracting strategies based on time and frequency domain characteristics, nonlinear, wavelet based entropy and few statistical features. A deeper study was undertaken using novel machine learning classifiers by considering multiple factors. The support vector machine kernels are evaluated based on multiclass kernel and box constraint level. Likewise, for K-nearest neighbors (KNN), we computed the different distance metrics, Neighbor weights and Neighbors. Similarly, the decision trees we tuned the paramours based on maximum splits and split criteria and ensemble classifiers are evaluated based on different ensemble methods and learning rate. For training/testing tenfold Cross validation was employed and performance was evaluated in form of TPR, NPR, PPV, accuracy and AUC. In this research, a deeper analysis approach was performed using diverse features extracting strategies using robust machine learning classifiers with more advanced optimal options. Support Vector Machine linear kernel and KNN with City block distance metric give the overall highest accuracy of 99.5% which was higher than using the default parameters for these classifiers. Moreover, highest separation (AUC = 0.9991, 0.9990) were obtained at different kernel scales using SVM. Additionally, the K-nearest neighbors with inverse squared distance weight give higher performance at different Neighbors. Moreover, to distinguish the postictal heart rate oscillations from epileptic ictal subjects, and highest performance of 100% was obtained using different machine learning classifiers.

  16. Correlation of free-response and receiver-operating-characteristic area-under-the-curve estimates: Results from independently conducted FROC/ROC studies in mammography

    International Nuclear Information System (INIS)

    Zanca, Federica; Hillis, Stephen L.; Claus, Filip; Van Ongeval, Chantal; Celis, Valerie; Provoost, Veerle; Yoon, Hong-Jun; Bosmans, Hilde

    2012-01-01

    Purpose: From independently conducted free-response receiver operating characteristic (FROC) and receiver operating characteristic (ROC) experiments, to study fixed-reader associations between three estimators: the area under the alternative FROC (AFROC) curve computed from FROC data, the area under the ROC curve computed from FROC highest rating data, and the area under the ROC curve computed from confidence-of-disease ratings. Methods: Two hundred mammograms, 100 of which were abnormal, were processed by two image-processing algorithms and interpreted by four radiologists under the FROC paradigm. From the FROC data, inferred-ROC data were derived, using the highest rating assumption. Eighteen months afterwards, the images were interpreted by the same radiologists under the conventional ROC paradigm; conventional-ROC data (in contrast to inferred-ROC data) were obtained. FROC and ROC (inferred, conventional) data were analyzed using the nonparametric area-under-the-curve (AUC), (AFROC and ROC curve, respectively). Pearson correlation was used to quantify the degree of association between the modality-specific AUC indices and standard errors were computed using the bootstrap-after-bootstrap method. The magnitude of the correlations was assessed by comparison with computed Obuchowski-Rockette fixed reader correlations. Results: Average Pearson correlations (with 95% confidence intervals in square brackets) were: Corr(FROC, inferred ROC) = 0.76[0.64, 0.84] > Corr(inferred ROC, conventional ROC) = 0.40[0.18, 0.58] > Corr (FROC, conventional ROC) = 0.32[0.16, 0.46]. Conclusions: Correlation between FROC and inferred-ROC data AUC estimates was high. Correlation between inferred- and conventional-ROC AUC was similar to the correlation between two modalities for a single reader using one estimation method, suggesting that the highest rating assumption might be questionable.

  17. Comparison of 18F-FET PET and perfusion-weighted MRI for glioma grading. A hybrid PET/MR study

    International Nuclear Information System (INIS)

    Verger, Antoine; Filss, Christian P.; Lohmann, Philipp; Stoffels, Gabriele; Rota Kops, Elena; Sabel, Michael; Wittsack, Hans J.; Galldiks, Norbert; Fink, Gereon R.; Shah, Nadim J.; Langen, Karl-Josef

    2017-01-01

    Both perfusion-weighted MR imaging (PWI) and O-(2- 18 F-fluoroethyl)-L-tyrosine PET ( 18 F-FET) provide grading information in cerebral gliomas. The aim of this study was to compare the diagnostic value of 18 F-FET PET and PWI for tumor grading in a series of patients with newly diagnosed, untreated gliomas using an integrated PET/MR scanner. Seventy-two patients with untreated gliomas [22 low-grade gliomas (LGG), and 50 high-grade gliomas (HGG)] were investigated with 18 F-FET PET and PWI using a hybrid PET/MR scanner. After visual inspection of PET and PWI maps (rCBV, rCBF, MTT), volumes of interest (VOIs) with a diameter of 16 mm were centered upon the maximum of abnormality in the tumor area in each modality and the contralateral unaffected hemisphere. Mean and maximum tumor-to-brain ratios (TBR mean , TBR max ) were calculated. In addition, Time-to-Peak (TTP) and slopes of time-activity curves were calculated for 18 F-FET PET. Diagnostic accuracies of 18 F-FET PET and PWI for differentiating low-grade glioma (LGG) from high-grade glioma (HGG) were evaluated by receiver operating characteristic analyses (area under the curve; AUC). The diagnostic accuracy of 18 F-FET PET and PWI to discriminate LGG from HGG was similar with highest AUC values for TBR mean and TBR max of 18 F-FET PET uptake (0.80, 0.83) and for TBR mean and TBR max of rCBV (0.80, 0.81). In case of increased signal in the tumor area with both methods (n = 32), local hot-spots were incongruent in 25 patients (78%) with a mean distance of 10.6 ± 9.5 mm. Dynamic FET PET and combination of different parameters did not further improve diagnostic accuracy. Both 18 F-FET PET and PWI discriminate LGG from HGG with similar diagnostic performance. Regional abnormalities in the tumor area are usually not congruent indicating that tumor grading by 18 F-FET PET and PWI is based on different pathophysiological phenomena. (orig.)

  18. Diagnostic accuracy in virtual dermatopathology

    DEFF Research Database (Denmark)

    Mooney, E.; Kempf, W.; Jemec, G.B.E.

    2012-01-01

    Background Virtual microscopy is used for teaching medical students and residents and for in-training and certification examinations in the United States. However, no existing studies compare diagnostic accuracy using virtual slides and photomicrographs. The objective of this study was to compare...... diagnostic accuracy of dermatopathologists and pathologists using photomicrographs vs. digitized images, through a self-assessment examination, and to elucidate assessment of virtual dermatopathology. Methods Forty-five dermatopathologists and pathologists received a randomized combination of 15 virtual...... slides and photomicrographs with corresponding clinical photographs and information in a self-assessment examination format. Descriptive data analysis and comparison of groups were performed using a chi-square test. Results Diagnostic accuracy in dermatopathology using virtual dermatopathology...

  19. In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions.

    Science.gov (United States)

    Ender, Andreas; Mehl, Albert

    2015-01-01

    To investigate the accuracy of conventional and digital impression methods used to obtain full-arch impressions by using an in-vitro reference model. Eight different conventional (polyether, POE; vinylsiloxanether, VSE; direct scannable vinylsiloxanether, VSES; and irreversible hydrocolloid, ALG) and digital (CEREC Bluecam, CER; CEREC Omnicam, OC; Cadent iTero, ITE; and Lava COS, LAV) full-arch impressions were obtained from a reference model with a known morphology, using a highly accurate reference scanner. The impressions obtained were then compared with the original geometry of the reference model and within each test group. A point-to-point measurement of the surface of the model using the signed nearest neighbour method resulted in a mean (10%-90%)/2 percentile value for the difference between the impression and original model (trueness) as well as the difference between impressions within a test group (precision). Trueness values ranged from 11.5 μm (VSE) to 60.2 μm (POE), and precision ranged from 12.3 μm (VSE) to 66.7 μm (POE). Among the test groups, VSE, VSES, and CER showed the highest trueness and precision. The deviation pattern varied with the impression method. Conventional impressions showed high accuracy across the full dental arch in all groups, except POE and ALG. Conventional and digital impression methods show differences regarding full-arch accuracy. Digital impression systems reveal higher local deviations of the full-arch model. Digital intraoral impression systems do not show superior accuracy compared to highly accurate conventional impression techniques. However, they provide excellent clinical results within their indications applying the correct scanning technique.

  20. The Concave Shape of the Forced Expiratory Flow-Volume Curve in 3 Seconds Is a Practical Surrogate of FEV1/FVC for the Diagnosis of Airway Limitation in Inadequate Spirometry.

    Science.gov (United States)

    Li, Hao; Liu, Chunhong; Zhang, Yi; Xiao, Wei

    2017-03-01

    Spirometry is important for the differential diagnosis of dyspnea. However, some patients cannot exhale for ≥6 s to achieve the American Thoracic Society/European Respiratory Society criteria. The aim of this study was to demonstrate the reliability of a new parameter that quantifies the degree of concavity in the first 3 s to define airway limitation as a surrogate for the FEV 1 /FVC. Four hundred spirometry test results were selected through complete random sampling. The new parameter, termed the AUC 3 /AT 3 , was calculated as the area under the descending limb of the expiratory flow-volume curve before the end of the first 3 s (AUC 3 ) divided by the area of the triangle before the end of the first 3 s (AT 3 ). The AUC 3 /AT 3 was compared with the FEV 1 /FVC using Pearson's correlation analysis. The level of agreement between the AUC 3 /AT 3 and the FEV 1 /FVC in the detection of airway obstruction was analyzed using the kappa statistic. We also compared the diagnostic accuracy of the new index with that of the FEV 1 /forced expiratory volume in the first 3 s (FEV 3 ). There was a strong correlation (r = 0.88, P < .001) between the AUC 3 /AT 3 and the FEV 1 /FVC. There was also strong agreement between the AUC 3 /AT 3 and the FEV 1 /FVC in the detection of obstruction with kappa indices of 0.72 (Global Initiative for Chronic Obstructive Lung Disease [GOLD] criterion) and 0.67 (lower limit of normal criterion), and these values were greater than those obtained for the FEV 1 /FEV 3 . The AUC 3 /AT 3 also exhibited acceptable sensitivity, specificity, positive predictive value, and negative predictive value. The diagnostic accuracies of the AUC 3 /AT 3 were 86.3% (GOLD criterion) and 83.8% (lower limit of normal criterion), which were greater than the 76.0 and 74.0% obtained for the FEV 1 /FEV 3 , respectively. The AUC 3 /AT 3 can be utilized as a surrogate parameter for the FEV 1 /FVC when patients cannot complete a 6-s expiratory effort. Additionally, the

  1. SU-D-204-04: Correlations Between Dosimetric Indices and Follow-Up Data for Salivary Glands Six Months After Radiation Therapy for Head and Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chera, B; Price, A; Kostich, M; Green, R; Das, S; Mavroidis, P [University of North Carolina, Chapel Hill, North Carolina (United States); Amdur, R; Mendenhall, W [University of Florida, Gainesville, FL (United States); Sheets, N [University of North Carolina, Raleigh, North Carolina (United States); Marks, L [UNC School of Medicine, Chapel Hill, NC (United States)

    2016-06-15

    Purpose: To investigate the correlation between different dosimetric indices of salivary glands (as separate or combined structures) to patient-reported dry mouth 6 months post radiotherapy using the novel patient reported outcome version of the CTCAE (PRO-CTCAE). Methods: Forty-three patients with oropharyngeal squamous cell carcinoma were treated on a prospective multi-institutional study. All patients received de-intensified 60 Gy intensity modulated radiotherapy. Dosimetric constraints were used for the salivary glands (e.g. mean dose to the contralateral-parotid < 26 Gy). We investigated correlations of individual patient dosimetric data of the parotid and submandibular glands (as separate or combined structures) to their self-reported 6 month post-treatment dry mouth responses. Moderate dry mouth responses were most prevalent and were used as the clinical endpoint indicating response. The correlation of Dmean, Dmax and a range of dosevolume (VD) points were assessed through the area under the Receiver Operating Characteristic curve (ROC) and Odds Ratios (OR). Results: Patients reporting non/mild dry mouth response (N=22) had average Dmean = 19.6 ± 6.2Gy to the contralateral-parotid compared to an average Dmean = 28.0 ± 8.3Gy and an AUC = 0.758 for the patients reporting moderate/severe/very severe dry mouth (N=21). Analysis of the range of VD’s for patients who had reported dry mouth showed that for the contralateral-parotid the indices V18 through V22 had the highest area under the curves (AUC) (0.762 – 0.772) compared to a more traditional dosimetric index V30, which had an AUC = 0.732. The highest AUC was observed for the combination of contralateral parotid and contralateral submandibular glands, for which V16 through V28 had AUC = 0.801 – 0.834. Conclusion: Patients who report moderate/severe/very severe dry mouth 6 months post radiotherapy had on average higher Dmean. The V16-V28 of the combination of the contralateral glands showed the highest

  2. DCE-MRI texture analysis with tumor subregion partitioning for predicting Ki-67 status of estrogen receptor-positive breast cancers

    KAUST Repository

    Fan, Ming

    2017-12-08

    Breast tumor heterogeneity is related to risk factors that lead to worse prognosis, yet such heterogeneity has not been well studied.To predict the Ki-67 status of estrogen receptor (ER)-positive breast cancer patients via analysis of tumor heterogeneity with subgroup identification based on patterns of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI).Retrospective study.Seventy-seven breast cancer patients with ER-positive breast cancer were investigated, of whom 51 had low Ki-67 expression.T1 -weighted 3.0T DCE-MR images.Each tumor was partitioned into multiple subregions using three methods based on patterns of dynamic enhancement: 1) time to peak (TTP), 2) peak enhancement rate (PER), and 3) kinetic pattern clustering (KPC). In each tumor subregion, 18 texture features were computed.Univariate and multivariate logistic regression analyses were performed using a leave-one-out-based cross-validation (LOOCV) method. The partitioning results were compared with the same feature extraction methods across the whole tumor.In the univariate analysis, the best-performing feature was the texture statistic of sum variance in the tumor subregion with early TTP for differentiating between patients with high and low Ki-67 expression (area under the receiver operating characteristic curves, AUC = 0.748). Multivariate analysis showed that features from the tumor subregion associated with early TTP yielded the highest performance (AUC = 0.807) among the subregions for predicting the Ki-67 status. Among all regions, the tumor area with high PER at a precontrast MR image achieved the highest performance (AUC = 0.722), while the subregion that exhibited the highest overall enhancement rate based on KPC had an AUC of 0.731. These three models based on intratumoral texture analysis significantly (P < 0.01) outperformed the model using features from the whole tumor (AUC = 0.59).Texture analysis of intratumoral heterogeneity has the potential to serve as a valuable

  3. Accuracy and precision of four common peripheral temperature measurement methods in intensive care patients.

    Science.gov (United States)

    Asadian, Simin; Khatony, Alireza; Moradi, Gholamreza; Abdi, Alireza; Rezaei, Mansour

    2016-01-01

    An accurate determination of body temperature in critically ill patients is a fundamental requirement for initiating the proper process of diagnosis, and also therapeutic actions; therefore, the aim of the study was to assess the accuracy and precision of four noninvasive peripheral methods of temperature measurement compared to the central nasopharyngeal measurement. In this observational prospective study, 237 patients were recruited from the intensive care unit of Imam Ali Hospital of Kermanshah. The patients' body temperatures were measured by four peripheral methods; oral, axillary, tympanic, and forehead along with a standard central nasopharyngeal measurement. After data collection, the results were analyzed by paired t-test, kappa coefficient, receiver operating characteristic curve, and using Statistical Package for the Social Sciences, version 19, software. There was a significant meaningful correlation between all the peripheral methods when compared with the central measurement (Ptemperatures of right and left tympanic membranes and the standard central nasopharyngeal measurement (88%). Paired t-test demonstrated an acceptable precision with forehead (P=0.132), left (P=0.18) and right (P=0.318) tympanic membranes, oral (P=1.00), and axillary (P=1.00) methods. Sensitivity and specificity of both the left and right tympanic membranes were more than for other methods. The tympanic and forehead methods had the highest and lowest accuracy for measuring body temperature, respectively. It is recommended to use the tympanic method (right and left) for assessing a patient's body temperature in the intensive care units because of high accuracy and acceptable precision.

  4. Preoperative prediction of sentinel lymph node metastasis in breast cancer based on radiomics of T2-weighted fat-suppression and diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Yuhao; Mo, Xiaokai [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); Shantou University Medical College, Graduate College, Shantou, Guangdong (China); Feng, Qianjin; Yang, Wei; Lu, Zixiao; Deng, Chunyan [Southern Medical University, The Guangdong Provincial Key Laboratory of Medical Image Processing, School of Biomedical Engineering, Guangzhou, Guangdong (China); Zhang, Lu; Lian, Zhouyang; Liu, Jing; Luo, Xiaoning; Pei, Shufang; Huang, Wenhui; Liang, Changhong; Zhang, Bin; Zhang, Shuixing [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China)

    2018-02-15

    To predict sentinel lymph node (SLN) metastasis in breast cancer patients using radiomics based on T{sub 2}-weighted fat suppression (T{sub 2}-FS) and diffusion-weighted MRI (DWI). We enrolled 146 patients with histologically proven breast cancer. All underwent pretreatment T{sub 2}-FS and DWI MRI scan. In all, 10,962 texture and four non-texture features were extracted for each patient. The 0.623 + bootstrap method and the area under the curve (AUC) were used to select the features. We constructed ten logistic regression models (orders of 1-10) based on different combination of image features using stepwise forward method. For T{sub 2}-FS, model 10 with ten features yielded the highest AUC of 0.847 in the training set and 0.770 in the validation set. For DWI, model 8 with eight features reached the highest AUC of 0.847 in the training set and 0.787 in the validation set. For joint T{sub 2}-FS and DWI, model 10 with ten features yielded an AUC of 0.863 in the training set and 0.805 in the validation set. Full utilisation of breast cancer-specific textural features extracted from anatomical and functional MRI images improves the performance of radiomics in predicting SLN metastasis, providing a non-invasive approach in clinical practice. (orig.)

  5. Sensitivity of tumor motion simulation accuracy to lung biomechanical modeling approaches and parameters.

    Science.gov (United States)

    Tehrani, Joubin Nasehi; Yang, Yin; Werner, Rene; Lu, Wei; Low, Daniel; Guo, Xiaohu; Wang, Jing

    2015-11-21

    Finite element analysis (FEA)-based biomechanical modeling can be used to predict lung respiratory motion. In this technique, elastic models and biomechanical parameters are two important factors that determine modeling accuracy. We systematically evaluated the effects of lung and lung tumor biomechanical modeling approaches and related parameters to improve the accuracy of motion simulation of lung tumor center of mass (TCM) displacements. Experiments were conducted with four-dimensional computed tomography (4D-CT). A Quasi-Newton FEA was performed to simulate lung and related tumor displacements between end-expiration (phase 50%) and other respiration phases (0%, 10%, 20%, 30%, and 40%). Both linear isotropic and non-linear hyperelastic materials, including the neo-Hookean compressible and uncoupled Mooney-Rivlin models, were used to create a finite element model (FEM) of lung and tumors. Lung surface displacement vector fields (SDVFs) were obtained by registering the 50% phase CT to other respiration phases, using the non-rigid demons registration algorithm. The obtained SDVFs were used as lung surface displacement boundary conditions in FEM. The sensitivity of TCM displacement to lung and tumor biomechanical parameters was assessed in eight patients for all three models. Patient-specific optimal parameters were estimated by minimizing the TCM motion simulation errors between phase 50% and phase 0%. The uncoupled Mooney-Rivlin material model showed the highest TCM motion simulation accuracy. The average TCM motion simulation absolute errors for the Mooney-Rivlin material model along left-right, anterior-posterior, and superior-inferior directions were 0.80 mm, 0.86 mm, and 1.51 mm, respectively. The proposed strategy provides a reliable method to estimate patient-specific biomechanical parameters in FEM for lung tumor motion simulation.

  6. Accuracies of genomic breeding values in American Angus beef cattle using K-means clustering for cross-validation.

    Science.gov (United States)

    Saatchi, Mahdi; McClure, Mathew C; McKay, Stephanie D; Rolf, Megan M; Kim, JaeWoo; Decker, Jared E; Taxis, Tasia M; Chapple, Richard H; Ramey, Holly R; Northcutt, Sally L; Bauck, Stewart; Woodward, Brent; Dekkers, Jack C M; Fernando, Rohan L; Schnabel, Robert D; Garrick, Dorian J; Taylor, Jeremy F

    2011-11-28

    the recurrent inclusion of genotyped sires in retraining analyses will be necessary to routinely produce for the industry the direct genomic values with the highest accuracy.

  7. Intravoxel Incoherent Motion Metrics as Potential Biomarkers for Survival in Glioblastoma.

    Directory of Open Access Journals (Sweden)

    Josep Puig

    Full Text Available Intravoxel incoherent motion (IVIM is an MRI technique with potential applications in measuring brain tumor perfusion, but its clinical impact remains to be determined. We assessed the usefulness of IVIM-metrics in predicting survival in newly diagnosed glioblastoma.Fifteen patients with glioblastoma underwent MRI including spin-echo echo-planar DWI using 13 b-values ranging from 0 to 1000 s/mm2. Parametric maps for diffusion coefficient (D, pseudodiffusion coefficient (D*, and perfusion fraction (f were generated for contrast-enhancing regions (CER and non-enhancing regions (NCER. Regions of interest were manually drawn in regions of maximum f and on the corresponding dynamic susceptibility contrast images. Prognostic factors were evaluated by Kaplan-Meier survival and Cox proportional hazards analyses.We found that fCER and D*CER correlated with rCBFCER. The best cutoffs for 6-month survival were fCER>9.86% and D*CER>21.712 x10-3mm2/s (100% sensitivity, 71.4% specificity, 100% and 80% positive predictive values, and 80% and 100% negative predictive values; AUC:0.893 and 0.857, respectively. Treatment yielded the highest hazard ratio (5.484; 95% CI: 1.162-25.88; AUC: 0.723; P = 0.031; fCER combined with treatment predicted survival with 100% accuracy.The IVIM-metrics fCER and D*CER are promising biomarkers of 6-month survival in newly diagnosed glioblastoma.

  8. Eyebrow hairs from actinic keratosis patients harbor the highest number of cutaneous human papillomaviruses.

    Science.gov (United States)

    Schneider, Ines; Lehmann, Mandy D; Kogosov, Vlada; Stockfleth, Eggert; Nindl, Ingo

    2013-04-24

    Cutaneous human papillomavirus (HPV) infections seem to be associated with the onset of actinic keratosis (AK). This study compares the presence of cutaneous HPV types in eyebrow hairs to those in tissues of normal skin and skin lesions of 75 immunocompetent AK patients. Biopsies from AK lesions, normal skin and plucked eyebrow hairs were collected from each patient. DNA from these specimens was tested for the presence of 28 cutaneous HPV (betaPV and gammaPV) by a PCR based method. The highest number of HPV prevalence was detected in 84% of the eyebrow hairs (63/75, median 6 types) compared to 47% of AK lesions (35/75, median 3 types) (pAK and 69 in normal skin. In all three specimens HPV20, HPV23 and/or HPV37 were the most prevalent types. The highest number of multiple types of HPV positive specimens was found in 76% of the eyebrow hairs compared to 60% in AK and 57% in normal skin. The concordance of at least one HPV type in virus positive specimens was 81% (three specimens) and 88-93% of all three combinations with two specimens. Thus, eyebrow hairs revealed the highest number of cutaneous HPV infections, are easy to collect and are an appropriate screening tool in order to identify a possible association of HPV and AK.

  9. Observations of the highest energy gamma-rays from gamma-ray bursts

    International Nuclear Information System (INIS)

    Dingus, Brenda L.

    2001-01-01

    EGRET has extended the highest energy observations of gamma-ray bursts to GeV gamma rays. Such high energies imply the fireball that is radiating the gamma-rays has a bulk Lorentz factor of several hundred. However, EGRET only detected a few gamma-ray bursts. GLAST will likely detect several hundred bursts and may extend the maximum energy to a few 100 GeV. Meanwhile new ground based detectors with sensitivity to gamma-ray bursts are beginning operation, and one recently reported evidence for TeV emission from a burst

  10. Improving Accuracy of Processing Through Active Control

    Directory of Open Access Journals (Sweden)

    N. N. Barbashov

    2016-01-01

    Full Text Available An important task of modern mathematical statistics with its methods based on the theory of probability is a scientific estimate of measurement results. There are certain costs under control, and under ineffective control when a customer has got defective products these costs are significantly higher because of parts recall.When machining the parts, under the influence of errors a range scatter of part dimensions is offset towards the tolerance limit. To improve a processing accuracy and avoid defective products involves reducing components of error in machining, i.e. to improve the accuracy of machine and tool, tool life, rigidity of the system, accuracy of the adjustment. In a given time it is also necessary to adapt machine.To improve an accuracy and a machining rate there, currently  become extensively popular various the in-process gaging devices and controlled machining that uses adaptive control systems for the process monitoring. Improving the accuracy in this case is compensation of a majority of technological errors. The in-cycle measuring sensors (sensors of active control allow processing accuracy improvement by one or two quality and provide a capability for simultaneous operation of several machines.Efficient use of in-cycle measuring sensors requires development of methods to control the accuracy through providing the appropriate adjustments. Methods based on the moving average, appear to be the most promising for accuracy control since they include data on the change in some last measured values of the parameter under control.

  11. Kolliphor surfactants affect solubilization and bioavailability of fenofibrate. Studies of in vitro digestion and absorption in rats

    DEFF Research Database (Denmark)

    Berthelsen, Ragna; Holm, Rene; Jacobsen, Jette

    2015-01-01

    formulations only comprised an aqueous micellar solution of the model drug (fenofibrate) in varying concentrations (2–25% (w/v)) of the three tested surfactants. Increased concentrations of Kolliphor ELP and EL led to increased fenofibrate AUC0–24h values. For the Kolliphor RH40 formulations, an apparent...... fenofibrate absorption optimum was seen at 15% (w/v) surfactant, displaying both the highest AUC0–24h and Cmax. The reduced absorption of fenofibrate from the formulation containing the highest level of surfactant (25% w/v) was thought to be caused by some degree of trapping within Kolliphor RH40 micelles....... In vitro, Kolliphor ELP and EL were found to be more prone to digestion than Kolliphor RH40, though not affecting the in vivo results. The highest fenofibrate bioavailability was attained from formulations with high Kolliphor ELP/EL levels (25% (w/v)), indicating that these surfactants are the better...

  12. Accuracy and precision in thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Marshall, T.O.

    1984-01-01

    The question of accuracy and precision in thermoluminescent dosimetry, particularly in relation to lithium fluoride phosphor, is discussed. The more important sources of error, including those due to the detectors, the reader, annealing and dosemeter design, are identified and methods of reducing their effects on accuracy and precision to a minimum are given. Finally, the accuracy and precision achievable for three quite different applications are discussed, namely, for personal dosimetry, environmental monitoring and for the measurement of photon dose distributions in phantoms. (U.K.)

  13. Comparison of saline infusion sonohysterography and hysteroscopy in diagnosis of premenopausal women with abnormal uterine bleeding.

    Science.gov (United States)

    Soguktas, Suna; Cogendez, Ebru; Kayatas, Semra Eser; Asoglu, Mehmet Resit; Selcuk, Selcuk; Ertekin, Aktug

    2012-03-01

    The aim of this study was to compare the diagnostic effectiveness of transvaginal sonography (TVS), saline infusion sonohysterography (SIS), and diagnostic hysteroscopy (HS), with the pathologic specimen as a gold standard diagnostic method, in detecting endometrial pathology in premenopausal women with abnormal uterine bleeding. This prospective cohort study was conducted at Zeynep Kamil Education and Training Hospital, Istanbul, Turkey, and included 89 premenopausal women. All participants were examined first by TVS, further investigated with SIS and HS, and finally dilatation and curettage was performed when needed. The results obtained from these three methods were compared with the pathologic diagnoses. The positive and negative likelihood ratios (LR+ and LR-) of TVS, SIS and HS were calculated by comparison with the final pathological diagnosis. In addition, area under the curve (AUC) values were also calculated. Polypoid lesion was the most common abnormal pathology. LR+ and LR- of TVS, SIS, and HS were 3.13 and 0.15, 9.83 and 0.07, 13.7 and 0.02 respectively in detection of any abnormal pathology, and the AUCs of TVS, SIS, and HS were 0.804, 0.920, and 0.954 respectively. When the three procedures were compared with each other separately, HS had the best diagnostic accuracy, and the diagnostic accuracy of HS and SIS was superior to TVS (p(1)=0.000, p(2)=0.000). For the detection of polypoid lesions, HS was the most accurate diagnostic procedure (AUC=0.947), followed by SIS (AUC=0.894) and TVS (AUC=0.778). HS provides the most accurate diagnosis and allows treatment in the same session in premenopausal women with abnormal uterine bleeding. Published by Elsevier Ireland Ltd.

  14. Cadastral Database Positional Accuracy Improvement

    Science.gov (United States)

    Hashim, N. M.; Omar, A. H.; Ramli, S. N. M.; Omar, K. M.; Din, N.

    2017-10-01

    Positional Accuracy Improvement (PAI) is the refining process of the geometry feature in a geospatial dataset to improve its actual position. This actual position relates to the absolute position in specific coordinate system and the relation to the neighborhood features. With the growth of spatial based technology especially Geographical Information System (GIS) and Global Navigation Satellite System (GNSS), the PAI campaign is inevitable especially to the legacy cadastral database. Integration of legacy dataset and higher accuracy dataset like GNSS observation is a potential solution for improving the legacy dataset. However, by merely integrating both datasets will lead to a distortion of the relative geometry. The improved dataset should be further treated to minimize inherent errors and fitting to the new accurate dataset. The main focus of this study is to describe a method of angular based Least Square Adjustment (LSA) for PAI process of legacy dataset. The existing high accuracy dataset known as National Digital Cadastral Database (NDCDB) is then used as bench mark to validate the results. It was found that the propose technique is highly possible for positional accuracy improvement of legacy spatial datasets.

  15. Predicting pathologic tumor response to chemoradiotherapy with histogram distances characterizing longitudinal changes in 18F-FDG uptake patterns

    Science.gov (United States)

    Tan, Shan; Zhang, Hao; Zhang, Yongxue; Chen, Wengen; D’Souza, Warren D.; Lu, Wei

    2013-01-01

    (AUC = 0.87), and match distance (AUC = 0.84). These crossbin histogram distance features showed slightly higher prediction accuracy than texture features on post-PET images. Conclusions: The results suggest that longitudinal patterns in 18F-FDG uptake characterized using histogram distances provide useful information for predicting the pathologic response of esophageal cancer to CRT. PMID:24089897

  16. Shoulder pain in primary care: diagnostic accuracy of clinical examination tests for non-traumatic acromioclavicular joint pain

    Science.gov (United States)

    2013-01-01

    Background Despite numerous methodological flaws in previous study designs and the lack of validation in primary care populations, clinical tests for identifying acromioclavicular joint (ACJ) pain are widely utilised without concern for such issues. The aim of this study was to estimate the diagnostic accuracy of traditional ACJ tests and to compare their accuracy with other clinical examination features for identifying a predominant ACJ pain source in a primary care cohort. Methods Consecutive patients with shoulder pain were recruited prospectively from primary health care clinics. Following a standardised clinical examination and diagnostic injection into the subacromial bursa, all participants received a fluoroscopically guided diagnostic block of 1% lidocaine hydrochloride (XylocaineTM) into the ACJ. Diagnostic accuracy statistics including sensitivity, specificity, predictive values, positive and negative likelihood ratios (LR+ and LR-) were calculated for traditional ACJ tests (Active Compression/O’Brien’s test, cross-body adduction, localised ACJ tenderness and Hawkins-Kennedy test), and for individual and combinations of clinical examination variables that were associated with a positive anaesthetic response (PAR) (P≤0.05) defined as 80% or more reduction in post-injection pain intensity during provocative clinical tests. Results Twenty two of 153 participants (14%) reported an 80% PAR. None of the traditional ACJ tests were associated with an 80% PAR (P0.05). Five clinical examination variables (repetitive mechanism of pain onset, no referred pain below the elbow, thickened or swollen ACJ, no symptom provocation during passive glenohumeral abduction and external rotation) were associated with an 80% PAR (P<0.05) and demonstrated an ability to accurately discriminate between an PAR and NAR (AUC 0.791; 95% CI 0.702, 0.880; P<0.001). Less than two positive clinical features resulted in 96% sensitivity (95% CI 0.78, 0.99) and a LR- 0.09 (95% CI 0.02, 0

  17. Could the erythrocyte indices or serum ferritin predict the therapeutic response to a trial with oral iron during pregnancy? Results from the Accuracy study for Maternal Anaemia diagnosis (AMA).

    Science.gov (United States)

    Bresani Salvi, Cristiane Campello; Braga, Maria Cynthia; Figueirôa, José Natal; Batista Filho, Malaquias

    2016-08-12

    Treatment of maternal iron-deficiency anaemia can reduce risks of prematurity and low birth weight; hence a reliable diagnosis of maternal iron needs is critical. However, erythrocyte indices and serum ferritin have shown a weak correlation with iron status during pregnancy. This study verified the accuracy of those tests to predict the responsiveness to a therapeutic test with oral iron as reference standard for iron deficiency in pregnant women. A prospective diagnostic study phase 3 was conducted in a single prenatal care center in Northeast Brazil. Between August 2011 and October 2012 a consecutive sampling included 187 women in their 2(nd)-3(rd) trimesters of low-risk pregnancy and having anaemia (haemoglobin <11.0 g/dL). Until December 2012, 139 women completed a trial with daily pills of ferrous sulfate (40 mg of iron), during 23 to 125 days. Haemoglobin (Hb), other erythrocyte indices and ferritin (index-tests) were assessed pre-treatment by automated analyzers. Hb was performed also post-treatment to assess the therapeutic response by its post-pretreatment differences. We estimated sensitivity (Se), specificity (Sp), predictive values (PV), likelihood ratios (LR), diagnostic Odds Ratio (OR), area under Receiver Operating Characteristic curve (AUC), accuracy ratio and agreement coefficient of the index-tests against an increase of at least 0.55 Hb Z-score (reference standard test). We calculated the Z-scores according to the reference population from Centers for Disease Control and Prevention. Hb had a mean increase of 0.24 Z-score after 30 iron pills (p 0.013). All index-tests demonstrated PV- above 70 %, PV+ around 40 %, LR around 1.0, and AUC of 0.5 to 0.6. Hb and haematocrit had Se of 50 % (95 % CI 40 to 70); and Sp of 59 % (95 % CI 43 to 74) and 47 % (95 % CI 38 to 57), respectively. Ferritin, Mean Corpuscular Volume, Mean Corpuscular Haemoglobin, Mean Corpuscular Haemoglobin Concentration and Red blood cell Distribution Width had Se below 40

  18. External validation of scoring systems in risk stratification of upper gastrointestinal bleeding.

    Science.gov (United States)

    Anchu, Anna Cherian; Mohsina, Subair; Sureshkumar, Sathasivam; Mahalakshmy, T; Kate, Vikram

    2017-03-01

    The aim of this study was to externally validate the four commonly used scoring systems in the risk stratification of patients with upper gastrointestinal bleed (UGIB). Patients of UGIB who underwent endoscopy within 24 h of presentation were stratified prospectively using the pre-endoscopy Rockall score (PRS) >0, complete Rockall score (CRS) >2, Glasgow Blatchford bleeding scores (GBS) >3, and modified GBS (m-GBS) >3 scores. Patients were followed up to 30 days. Prognostic accuracy of the scores was done by comparing areas under curve (AUC) in terms of overall risk stratification, re-bleeding, mortality, need for intervention, and length of hospitalization. One hundred and seventy-five patients were studied. All four scores performed better in the overall risk stratification on AUC [PRS = 0.566 (CI: 0.481-0.651; p-0.043)/CRS = 0.712 (CI: 0.634-0.790); p0.001); m-GBS = 0.802 (CI: 0.734-0.871; pbleed [AUC-0.679 (CI: 0.579-0.780; p = 0.003)]. All the scoring systems except PRS were found to be significantly better in detecting 30-day mortality with a high AUC (CRS = 0.798; p-0.042)/GBS = 0.833; p-0.023); m-GBS = 0.816; p-0.031). All four scores demonstrated significant accuracy in the risk stratification of non-variceal patients; however, only GBS and m-GBS were significant in variceal etiology. Higher cutoff scores achieved better sensitivity/specificity [RS > 0 (50/60.8), CRS > 1 (87.5/50.6), GBS > 7 (88.5/63.3), m-GBS > 7(82.3/72.6)] in the risk stratification. GBS and m-GBS appear to be more valid in risk stratification of UGIB patients in this region. Higher cutoff values achieved better predictive accuracy.

  19. Effect of cervical relining of acrylic resin copings on the accuracy of stone dies obtained using a polyether impression material

    Directory of Open Access Journals (Sweden)

    André Tomazini Gomes de Sá

    2008-02-01

    Full Text Available The purpose of this study was to evaluate the accuracy of the respective dies after polyether elastomeric procedure in the presence or absence of cervical contact of the acrylic resin shell with the cervical region, establishing a comparison to dies obtained with stock trays. This study consisted of three groups with 10 specimens each: 1 acrylic copings without cervical contact, (cn; 2 acrylic copings with cervical contact (cc; 3 perforated stock tray, (st. The accuracy of the resulting dies was verified with the aid of a master crown, precisely fit to the master steel die. ANOVA test found statistically significant differences among groups (p<0.001. Tukey's test found that the smallest discrepancy occurred in group cn, followed by cc, while the st group presented the highest difference (cc x cn: p=0.007; st x cn: p<0.001; st x cc: p<0.001.

  20. Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection.

    Science.gov (United States)

    Kamble, Suresh S; Khandeparker, Rakshit Vijay; Somasundaram, P; Raghav, Shweta; Babaji, Rashmi P; Varghese, T Joju

    2015-09-01

    Impression materials during impression procedure often get infected with various infectious diseases. Hence, disinfection of impression materials with various disinfectants is advised to protect the dental team. Disinfection can alter the dimensional accuracy of impression materials. The present study was aimed to evaluate the dimensional accuracy of elastomeric impression materials when treated with different disinfectants; autoclave, chemical, and microwave method. The impression materials used for the study were, dentsply aquasil (addition silicone polyvinylsiloxane syringe and putty), zetaplus (condensation silicone putty and light body), and impregum penta soft (polyether). All impressions were made according to manufacturer's instructions. Dimensional changes were measured before and after different disinfection procedures. Dentsply aquasil showed smallest dimensional change (-0.0046%) and impregum penta soft highest linear dimensional changes (-0.026%). All the tested elastomeric impression materials showed some degree of dimensional changes. The present study showed that all the disinfection procedures produce minor dimensional changes of impression material. However, it was within American Dental Association specification. Hence, steam autoclaving and microwave method can be used as an alternative method to chemical sterilization as an effective method.

  1. Diagnostic utility of novel MRI-based biomarkers for Alzheimer's disease: diffusion tensor imaging and deformation-based morphometry.

    Science.gov (United States)

    Friese, Uwe; Meindl, Thomas; Herpertz, Sabine C; Reiser, Maximilian F; Hampel, Harald; Teipel, Stefan J

    2010-01-01

    We report evidence that multivariate analyses of deformation-based morphometry and diffusion tensor imaging (DTI) data can be used to discriminate between healthy participants and patients with Alzheimer's disease (AD) with comparable diagnostic accuracy. In contrast to other studies on MRI-based biomarkers which usually only focus on a single modality, we derived deformation maps from high-dimensional normalization of T1-weighted images, as well as mean diffusivity maps and fractional anisotropy maps from DTI of the same group of 21 patients with AD and 20 healthy controls. Using an automated multivariate analysis of the entire brain volume, widespread decreased white matter integrity and atrophy effects were found in cortical and subcortical regions of AD patients. Mean diffusivity maps and deformation maps were equally effective in discriminating between AD patients and controls (AUC =0.88 vs. AUC=0.85) while fractional anisotropy maps performed slightly inferior. Combining the maps from different modalities in a logistic regression model resulted in a classification accuracy of AUC=0.86 after leave-one-out cross-validation. It remains to be shown if this automated multivariate analysis of DTI-measures can improve early diagnosis of AD in predementia stages.

  2. Predictive accuracy of changes in transvaginal sonographic cervical length over time for preterm birth: a systematic review and metaanalysis.

    Science.gov (United States)

    Conde-Agudelo, Agustin; Romero, Roberto

    2015-12-01

    To determine the accuracy of changes in transvaginal sonographic cervical length over time in predicting preterm birth in women with singleton and twin gestations. PubMed, Embase, Cinahl, Lilacs, and Medion (all from inception to June 30, 2015), bibliographies, Google scholar, and conference proceedings. Cohort or cross-sectional studies reporting on the predictive accuracy for preterm birth of changes in cervical length over time. Two reviewers independently selected studies, assessed the risk of bias, and extracted the data. Summary receiver-operating characteristic curves, pooled sensitivities and specificities, and summary likelihood ratios were generated. Fourteen studies met the inclusion criteria, of which 7 provided data on singleton gestations (3374 women) and 8 on twin gestations (1024 women). Among women with singleton gestations, the shortening of cervical length over time had a low predictive accuracy for preterm birth at predictive accuracy for preterm birth at predictive accuracies for preterm birth of cervical length shortening over time and the single initial and/or final cervical length measurement in 8 of 11 studies that provided data for making these comparisons. In the largest and highest-quality study, a single measurement of cervical length obtained at 24 or 28 weeks of gestation was significantly more predictive of preterm birth than any decrease in cervical length between these gestational ages. Change in transvaginal sonographic cervical length over time is not a clinically useful test to predict preterm birth in women with singleton or twin gestations. A single cervical length measurement obtained between 18 and 24 weeks of gestation appears to be a better test to predict preterm birth than changes in cervical length over time. Published by Elsevier Inc.

  3. The accuracy of polyuria, polydipsia, polyphagia, and Indian Diabetes Risk Score in adults screened for diabetes mellitus type-II

    Directory of Open Access Journals (Sweden)

    Shivshakti D Pawar

    2017-01-01

    Full Text Available Context: The World Health Organization report suggests that over 19% of the world's diabetic population currently resides in India. Unfortunately, >50% of the diabetics in India are unaware about their diabetic status. In the poor income country like India, it is essential to use cost-effective methods for screening for diabetes, and traditionally using three classical symptoms and Indian Diabetes Risk Score (IDRS tool is helpful but, data regarding their diagnostic accuracy is very less. Objective: (1 To assess the diagnostic accuracy of polyuria, polydipsia, polyphagia, and IDRS for detecting diabetes. Settings and Design: Six hundred and seventy-seven adult individuals> 20 years of age were screened for diabetes and assessed polyuria, polydipsia, polyphagia, and IDRS score. All were subjected for postprandial blood glucose level. Subjects and Methods: For diagnostic accuracy sensitivity, specificity, positive and negative predictive values, likelihood ratios (LRs, for positive and negative tests, and accuracy was calculated for each symptom. Similarly, by receiver operative curve (ROC curve analysis, we carried out sensitivity and specificity of IDRS. Results: There was statistically significant association between these three classical symptoms and diabetes status of individuals. When present, all these three symptoms carried 7.34% sensitivity and 98.42% specificity with positive predictive value 47.06% and NPV 84.70%, LR+4.36, LR−0.94 with accuracy of 85%. The optimum cutoff value of IDRS score was> 50, which carried sensitivity 73%, specificity 58.7%, and area under curve for ROC was 68% (P < 0.001. Conclusions: This study has shown highest specificity for these three classical symptoms in diagnosing diabetes, but these symptoms were insensitive to detect all diabetic subjects.

  4. THE ACCURACY AND BIAS EVALUATION OF THE USA UNEMPLOYMENT RATE FORECASTS. METHODS TO IMPROVE THE FORECASTS ACCURACY

    Directory of Open Access Journals (Sweden)

    MIHAELA BRATU (SIMIONESCU

    2012-12-01

    Full Text Available In this study some alternative forecasts for the unemployment rate of USA made by four institutions (International Monetary Fund (IMF, Organization for Economic Co-operation and Development (OECD, Congressional Budget Office (CBO and Blue Chips (BC are evaluated regarding the accuracy and the biasness. The most accurate predictions on the forecasting horizon 201-2011 were provided by IMF, followed by OECD, CBO and BC.. These results were gotten using U1 Theil’s statistic and a new method that has not been used before in literature in this context. The multi-criteria ranking was applied to make a hierarchy of the institutions regarding the accuracy and five important accuracy measures were taken into account at the same time: mean errors, mean squared error, root mean squared error, U1 and U2 statistics of Theil. The IMF, OECD and CBO predictions are unbiased. The combined forecasts of institutions’ predictions are a suitable strategy to improve the forecasts accuracy of IMF and OECD forecasts when all combination schemes are used, but INV one is the best. The filtered and smoothed original predictions based on Hodrick-Prescott filter, respectively Holt-Winters technique are a good strategy of improving only the BC expectations. The proposed strategies to improve the accuracy do not solve the problem of biasness. The assessment and improvement of forecasts accuracy have an important contribution in growing the quality of decisional process.

  5. The Accuracy of Plain Radiography in Detection of Traumatic Intrathoracic Injuries

    Directory of Open Access Journals (Sweden)

    Maryam Abedi Khorasgani

    2016-08-01

    Full Text Available Introduction: Rapid diagnosis of traumatic intrathoracic injuries leads to improvement in patient management. This study was designed to evaluate the diagnostic value of chest radiography (CXR in comparison to chest computed tomography (CT scan in diagnosis of traumatic intrathoracic injuries. Methods: Participants of this prospective diagnostic accuracy study included multiple trauma patients over 15 years old with stable vital admitted to emergency department (ED during one year. The correlation of CXR and CT scan findings in diagnosis of traumatic intrathoracic injuries was evaluated using SPSS 20. Screening characteristics of CXR were calculated with 95% CI. Results: 353 patients with the mean age of 35.2 ± 15.8 were evaluated (78.8% male. Age 16-30 years with 121 (34.2%, motorcycle riders with 104 (29.5% cases and ISS < 12 with 185 (52.4% had the highest frequency among patients. Generally, screening performance characteristics of chest in diagnosis of chest traumatic injuries were as follows: sensitivity 50.3 (95% CI: 44.8 – 55.5, specificity 98.9 (95% CI: 99.5 – 99.8, PPV 97.8 (95% CI: 91.5 – 99.6, NPV 66.4 (95% CI: 60.2 – 72.03, PLR 44.5 (95% CI: 11.3 175.3, and NLR 0.5 (95% CI: 0.4 – 0.6. Accuracy of CXR in diagnosis of traumatic intrathoracic injuries was 74.5 (95% CI: 69.6 – 78.9 and its area under the ROC curve was 74.6 (95% CI: 69.3 – 79.8. Conclusion: The screening performance characteristics of CXR in diagnosis of traumatic intrathoracic injuries were higher than 90% in all pathologies except pneumothorax (50.3%. It seems that this matter has a great impact on the general screening characteristics of the test (74.3% accuracy and 50.3%sensitivity. It seems that, plain CXR should be used as an initial screening tool more carefully.

  6. Highest weight generating functions for hyperKähler T{sup ⋆}(G/H) spaces

    Energy Technology Data Exchange (ETDEWEB)

    Hanany, Amihay [Theoretical Physics Group, Imperial College London,Prince Consort Road, London, SW7 2AZ (United Kingdom); Ramgoolam, Sanjaye [Centre for Research in String Theory,School of Physics and Astronomy, Queen Mary University of London,Mile End Road, London E1 4NS (United Kingdom); Rodriguez-Gomez, Diego [Department of Physics, Universidad de Oviedo,Avda. Calvo Sotelo 18, 33007, Oviedo (Spain)

    2016-10-05

    We develop an efficient procedure for counting holomorphic functions on a hyperKahler cone that has a resolution as a cotangent bundle of a homogeneous space by providing a formula for computing the corresponding Highest Weight Generating function.

  7. Addressing the Highest Risk: Environmental Programs at Los Alamos National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Forbes, Elaine E [Los Alamos National Laboratory

    2012-06-08

    Report topics: Current status of cleanup; Shift in priorities to address highest risk; Removal of above-ground waste; and Continued focus on protecting water resources. Partnership between the National Nuclear Security Administration's Los Alamos Site Office, DOE Carlsbad Field Office, New Mexico Environment Department, and contractor staff has enabled unprecedented cleanup progress. Progress on TRU campaign is well ahead of plan. To date, have completed 130 shipments vs. 104 planned; shipped 483 cubic meters of above-ground waste (vs. 277 planned); and removed 11,249 PE Ci of material at risk (vs. 9,411 planned).

  8. Comparative performance of different stochastic methods to simulate drug exposure and variability in a population.

    Science.gov (United States)

    Tam, Vincent H; Kabbara, Samer

    2006-10-01

    Monte Carlo simulations (MCSs) are increasingly being used to predict the pharmacokinetic variability of antimicrobials in a population. However, various MCS approaches may differ in the accuracy of the predictions. We compared the performance of 3 different MCS approaches using a data set with known parameter values and dispersion. Ten concentration-time profiles were randomly generated and used to determine the best-fit parameter estimates. Three MCS methods were subsequently used to simulate the AUC(0-infinity) of the population, using the central tendency and dispersion of the following in the subject sample: 1) K and V; 2) clearance and V; 3) AUC(0-infinity). In each scenario, 10000 subject simulations were performed. Compared to true AUC(0-infinity) of the population, mean biases by various methods were 1) 58.4, 2) 380.7, and 3) 12.5 mg h L(-1), respectively. Our results suggest that the most realistic MCS approach appeared to be based on the variability of AUC(0-infinity) in the subject sample.

  9. Improving coding accuracy in an academic practice.

    Science.gov (United States)

    Nguyen, Dana; O'Mara, Heather; Powell, Robert

    2017-01-01

    Practice management has become an increasingly important component of graduate medical education. This applies to every practice environment; private, academic, and military. One of the most critical aspects of practice management is documentation and coding for physician services, as they directly affect the financial success of any practice. Our quality improvement project aimed to implement a new and innovative method for teaching billing and coding in a longitudinal fashion in a family medicine residency. We hypothesized that implementation of a new teaching strategy would increase coding accuracy rates among residents and faculty. Design: single group, pretest-posttest. military family medicine residency clinic. Study populations: 7 faculty physicians and 18 resident physicians participated as learners in the project. Educational intervention: monthly structured coding learning sessions in the academic curriculum that involved learner-presented cases, small group case review, and large group discussion. overall coding accuracy (compliance) percentage and coding accuracy per year group for the subjects that were able to participate longitudinally. Statistical tests used: average coding accuracy for population; paired t test to assess improvement between 2 intervention periods, both aggregate and by year group. Overall coding accuracy rates remained stable over the course of time regardless of the modality of the educational intervention. A paired t test was conducted to compare coding accuracy rates at baseline (mean (M)=26.4%, SD=10%) to accuracy rates after all educational interventions were complete (M=26.8%, SD=12%); t24=-0.127, P=.90. Didactic teaching and small group discussion sessions did not improve overall coding accuracy in a residency practice. Future interventions could focus on educating providers at the individual level.

  10. Development and Validation of a Diabetic Retinopathy Referral Algorithm Based on Single-Field Fundus Photography.

    Directory of Open Access Journals (Sweden)

    Sangeetha Srinivasan

    Full Text Available To develop a simplified algorithm to identify and refer diabetic retinopathy (DR from single-field retinal images specifically for sight-threatening diabetic retinopathy for appropriate care (ii to determine the agreement and diagnostic accuracy of the algorithm as a pilot study among optometrists versus "gold standard" (retinal specialist grading.The severity of DR was scored based on colour photo using a colour coded algorithm, which included the lesions of DR and number of quadrants involved. A total of 99 participants underwent training followed by evaluation. Data of the 99 participants were analyzed. Fifty posterior pole 45 degree retinal images with all stages of DR were presented. Kappa scores (κ, areas under the receiver operating characteristic curves (AUCs, sensitivity and specificity were determined, with further comparison between working optometrists and optometry students.Mean age of the participants was 22 years (range: 19-43 years, 87% being women. Participants correctly identified 91.5% images that required immediate referral (κ = 0.696, 62.5% of images as requiring review after 6 months (κ = 0.462, and 51.2% of those requiring review after 1 year (κ = 0.532. The sensitivity and specificity of the optometrists were 91% and 78% for immediate referral, 62% and 84% for review after 6 months, and 51% and 95% for review after 1 year, respectively. The AUC was the highest (0.855 for immediate referral, second highest (0.824 for review after 1 year, and 0.727 for review after 6 months criteria. Optometry students performed better than the working optometrists for all grades of referral.The diabetic retinopathy algorithm assessed in this work is a simple and a fairly accurate method for appropriate referral based on single-field 45 degree posterior pole retinal images.

  11. Inclusion of Highest Glasgow Coma Scale Motor Component Score in Mortality Risk Adjustment for Benchmarking of Trauma Center Performance.

    Science.gov (United States)

    Gomez, David; Byrne, James P; Alali, Aziz S; Xiong, Wei; Hoeft, Chris; Neal, Melanie; Subacius, Harris; Nathens, Avery B

    2017-12-01

    The Glasgow Coma Scale (GCS) is the most widely used measure of traumatic brain injury (TBI) severity. Currently, the arrival GCS motor component (mGCS) score is used in risk-adjustment models for external benchmarking of mortality. However, there is evidence that the highest mGCS score in the first 24 hours after injury might be a better predictor of death. Our objective was to evaluate the impact of including the highest mGCS score on the performance of risk-adjustment models and subsequent external benchmarking results. Data were derived from the Trauma Quality Improvement Program analytic dataset (January 2014 through March 2015) and were limited to the severe TBI cohort (16 years or older, isolated head injury, GCS ≤8). Risk-adjustment models were created that varied in the mGCS covariates only (initial score, highest score, or both initial and highest mGCS scores). Model performance and fit, as well as external benchmarking results, were compared. There were 6,553 patients with severe TBI across 231 trauma centers included. Initial and highest mGCS scores were different in 47% of patients (n = 3,097). Model performance and fit improved when both initial and highest mGCS scores were included, as evidenced by improved C-statistic, Akaike Information Criterion, and adjusted R-squared values. Three-quarters of centers changed their adjusted odds ratio decile, 2.6% of centers changed outlier status, and 45% of centers exhibited a ≥0.5-SD change in the odds ratio of death after including highest mGCS score in the model. This study supports the concept that additional clinical information has the potential to not only improve the performance of current risk-adjustment models, but can also have a meaningful impact on external benchmarking strategies. Highest mGCS score is a good potential candidate for inclusion in additional models. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Multiple sequence alignment accuracy and phylogenetic inference.

    Science.gov (United States)

    Ogden, T Heath; Rosenberg, Michael S

    2006-04-01

    Phylogenies are often thought to be more dependent upon the specifics of the sequence alignment rather than on the method of reconstruction. Simulation of sequences containing insertion and deletion events was performed in order to determine the role that alignment accuracy plays during phylogenetic inference. Data sets were simulated for pectinate, balanced, and random tree shapes under different conditions (ultrametric equal branch length, ultrametric random branch length, nonultrametric random branch length). Comparisons between hypothesized alignments and true alignments enabled determination of two measures of alignment accuracy, that of the total data set and that of individual branches. In general, our results indicate that as alignment error increases, topological accuracy decreases. This trend was much more pronounced for data sets derived from more pectinate topologies. In contrast, for balanced, ultrametric, equal branch length tree shapes, alignment inaccuracy had little average effect on tree reconstruction. These conclusions are based on average trends of many analyses under different conditions, and any one specific analysis, independent of the alignment accuracy, may recover very accurate or inaccurate topologies. Maximum likelihood and Bayesian, in general, outperformed neighbor joining and maximum parsimony in terms of tree reconstruction accuracy. Results also indicated that as the length of the branch and of the neighboring branches increase, alignment accuracy decreases, and the length of the neighboring branches is the major factor in topological accuracy. Thus, multiple-sequence alignment can be an important factor in downstream effects on topological reconstruction.

  13. Accuracy Limitations in Optical Linear Algebra Processors

    Science.gov (United States)

    Batsell, Stephen Gordon

    1990-01-01

    One of the limiting factors in applying optical linear algebra processors (OLAPs) to real-world problems has been the poor achievable accuracy of these processors. Little previous research has been done on determining noise sources from a systems perspective which would include noise generated in the multiplication and addition operations, noise from spatial variations across arrays, and from crosstalk. In this dissertation, we propose a second-order statistical model for an OLAP which incorporates all these system noise sources. We now apply this knowledge to determining upper and lower bounds on the achievable accuracy. This is accomplished by first translating the standard definition of accuracy used in electronic digital processors to analog optical processors. We then employ our second-order statistical model. Having determined a general accuracy equation, we consider limiting cases such as for ideal and noisy components. From the ideal case, we find the fundamental limitations on improving analog processor accuracy. From the noisy case, we determine the practical limitations based on both device and system noise sources. These bounds allow system trade-offs to be made both in the choice of architecture and in individual components in such a way as to maximize the accuracy of the processor. Finally, by determining the fundamental limitations, we show the system engineer when the accuracy desired can be achieved from hardware or architecture improvements and when it must come from signal pre-processing and/or post-processing techniques.

  14. Diagnostic accuracy of 18F amyloid PET tracers for the diagnosis of Alzheimer's disease: a systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Morris, Elizabeth; Chalkidou, Anastasia; Hammers, Alexander; Peacock, Janet; Summers, Jennifer; Keevil, Stephen

    2016-01-01

    Imaging or tissue biomarker evidence has been introduced into the core diagnostic pathway for Alzheimer's disease (AD). PET using 18 F-labelled beta-amyloid PET tracers has shown promise for the early diagnosis of AD. However, most studies included only small numbers of participants and no consensus has been reached as to which radiotracer has the highest diagnostic accuracy. First, we performed a systematic review of the literature published between 1990 and 2014 for studies exploring the diagnostic accuracy of florbetaben, florbetapir and flutemetamol in AD. The included studies were analysed using the QUADAS assessment of methodological quality. A meta-analysis of the sensitivity and specificity reported within each study was performed. Pooled values were calculated for each radiotracer and for visual or quantitative analysis by population included. The systematic review identified nine studies eligible for inclusion. There were limited variations in the methods between studies reporting the same radiotracer. The meta-analysis results showed that pooled sensitivity and specificity values were in general high for all tracers. This was confirmed by calculating likelihood ratios. A patient with a positive ratio is much more likely to have AD than a patient with a negative ratio, and vice versa. However, specificity was higher when only patients with AD were compared with healthy controls. This systematic review and meta-analysis found no marked differences in the diagnostic accuracy of the three beta-amyloid radiotracers. All tracers perform better when used to discriminate between patients with AD and healthy controls. The sensitivity and specificity for quantitative and visual analysis are comparable to those of other imaging or biomarker techniques used to diagnose AD. Further research is required to identify the combination of tests that provides the highest sensitivity and specificity, and to identify the most suitable position for the tracer in the

  15. Quantitative accuracy assessment of thermalhydraulic code predictions with SARBM

    International Nuclear Information System (INIS)

    Prosek, A.

    2001-01-01

    In recent years, the nuclear reactor industry has focused significant attention on nuclear reactor systems code accuracy and uncertainty issues. A few methods suitable to quantify code accuracy of thermalhydraulic code calculations were proposed and applied in the past. In this study a Stochastic Approximation Ratio Based Method (SARBM) was adapted and proposed for accuracy quantification. The objective of the study was to qualify the SARBM. The study compare the accuracy obtained by SARBM with the results obtained by widely used Fast Fourier Transform Based Method (FFTBM). The methods were applied to RELAP5/MOD3.2 code calculations of various BETHSY experiments. The obtained results showed that the SARBM was able to satisfactorily predict the accuracy of the calculated trends when visually comparing plots and comparing the results with the qualified FFTBM. The analysis also showed that the new figure-of-merit called accuracy factor (AF) is more convenient than stochastic approximation ratio for combining single variable accuracy's into total accuracy. The accuracy results obtained for the selected tests suggest that the acceptability factors for the SAR method were reasonably defined. The results also indicate that AF is a useful quantitative measure of accuracy.(author)

  16. Bioavailability of four oral Coenzyme Q formulations in healthy volunteers

    DEFF Research Database (Denmark)

    Weis, M.; Mortensen, S.A.; Rassing, M.R.

    1994-01-01

    The bioavailability of four different Coenzyme Q (CoQ) formulations was compared in ten healthy volunteers in a four-way randomised cross-over trial. The included formulations were: A hard gelatine capsule containing 100 mg of CoQ and 400 mg of Emcompress. Three soft gelatine capsules containing......Q (Bioquinon has the highest bioavailability. A difference in basic AUC and AUC after p.o.administration of CoQ was observed with respect to sex. A characteristic two peak-pattern was observed at the concentration-time profile....

  17. Forecast Accuracy Uncertainty and Momentum

    OpenAIRE

    Bing Han; Dong Hong; Mitch Warachka

    2009-01-01

    We demonstrate that stock price momentum and earnings momentum can result from uncertainty surrounding the accuracy of cash flow forecasts. Our model has multiple information sources issuing cash flow forecasts for a stock. The investor combines these forecasts into an aggregate cash flow estimate that has minimal mean-squared forecast error. This aggregate estimate weights each cash flow forecast by the estimated accuracy of its issuer, which is obtained from their past forecast errors. Mome...

  18. Sensitivity of tumor motion simulation accuracy to lung biomechanical modeling approaches and parameters

    International Nuclear Information System (INIS)

    Tehrani, Joubin Nasehi; Wang, Jing; Yang, Yin; Werner, Rene; Lu, Wei; Low, Daniel; Guo, Xiaohu

    2015-01-01

    Finite element analysis (FEA)-based biomechanical modeling can be used to predict lung respiratory motion. In this technique, elastic models and biomechanical parameters are two important factors that determine modeling accuracy. We systematically evaluated the effects of lung and lung tumor biomechanical modeling approaches and related parameters to improve the accuracy of motion simulation of lung tumor center of mass (TCM) displacements. Experiments were conducted with four-dimensional computed tomography (4D-CT). A Quasi-Newton FEA was performed to simulate lung and related tumor displacements between end-expiration (phase 50%) and other respiration phases (0%, 10%, 20%, 30%, and 40%). Both linear isotropic and non-linear hyperelastic materials, including the neo-Hookean compressible and uncoupled Mooney–Rivlin models, were used to create a finite element model (FEM) of lung and tumors. Lung surface displacement vector fields (SDVFs) were obtained by registering the 50% phase CT to other respiration phases, using the non-rigid demons registration algorithm. The obtained SDVFs were used as lung surface displacement boundary conditions in FEM. The sensitivity of TCM displacement to lung and tumor biomechanical parameters was assessed in eight patients for all three models. Patient-specific optimal parameters were estimated by minimizing the TCM motion simulation errors between phase 50% and phase 0%. The uncoupled Mooney–Rivlin material model showed the highest TCM motion simulation accuracy. The average TCM motion simulation absolute errors for the Mooney–Rivlin material model along left-right, anterior–posterior, and superior–inferior directions were 0.80 mm, 0.86 mm, and 1.51 mm, respectively. The proposed strategy provides a reliable method to estimate patient-specific biomechanical parameters in FEM for lung tumor motion simulation. (paper)

  19. Accuracy Assessment of Timber Volume Maps Using Forest Inventory Data and LiDAR Canopy Height Models

    Directory of Open Access Journals (Sweden)

    Andreas Hill

    2014-09-01

    Full Text Available Maps of standing timber volume provide valuable decision support for forest managers and have therefore been the subject of recent studies. For map production, field observations are commonly combined with area-wide remote sensing data in order to formulate prediction models, which are then applied over the entire inventory area. The accuracy of such maps has frequently been described by parameters such as the root mean square error of the prediction model. The aim of this study was to additionally address the accuracy of timber volume classes, which are used to better represent the map predictions. However, the use of constant class intervals neglects the possibility that the precision of the underlying prediction model may not be constant across the entire volume range, resulting in pronounced gradients between class accuracies. This study proposes an optimization technique that automatically identifies a classification scheme which accounts for the properties of the underlying model and the implied properties of the remote sensing support information. We demonstrate the approach in a mountainous study site in Eastern Switzerland covering a forest area of 2000 hectares using a multiple linear regression model approach. A LiDAR-based canopy height model (CHM provided the auxiliary information; timber volume observations from the latest forest inventory were used for model calibration and map validation. The coefficient of determination (R2 = 0.64 and the cross-validated root mean square error (RMSECV = 123.79 m3 ha−1 were only slightly smaller than those of studies in less steep and heterogeneous landscapes. For a large set of pre-defined number of classes, the optimization model successfully identified those classification schemes that achieved the highest possible accuracies for each class.

  20. Measuring the airway in 3 dimensions: a reliability and accuracy study.

    Science.gov (United States)

    El, Hakan; Palomo, Juan Martin

    2010-04-01

    The aim of the study was to compare the reliability and accuracy of 3 commercially available digital imaging and communications in medicine (DICOM) viewers for measuring upper airway volumes. Thirty cone-beam computed tomography scans were randomly selected, and the upper airway volumes were calculated for both oropharynx and nasal passage. Dolphin3D (version 11, Dolphin Imaging & Management Solutions, Chatsworth, Calif), InVivoDental (version 4.0.70, Anatomage, San Jose, Calif), and OnDemand3D (version 1.0.1.8407, CyberMed, Seoul, Korea) were compared with a previously tested manual segmentation program called OrthoSegment (OS) (developed at the Department of Orthodontics at Case Western Reserve University, Cleveland, Ohio). The measurements were repeated after 2 weeks, and the ICC was used for the reliability tests. All commercially available programs were compared with the OS program by using regression analysis. The Pearson correlation was used to evaluate the correlation between the OS and the automatic segmentation programs. The reliability was high for all programs. The highest correlation found was between the OS and Dolphin3D for the oropharynx, and between the OS and InVivoDental for nasal passage volume. A high correlation was found for all programs, but the results also showed statistically significant differences compared with the OS program. The programs also had inconsistencies among themselves. The 3 commercially available DICOM viewers are highly reliable in their airway volume calculations and showed high correlation of results but poor accuracy, suggesting systematic errors. Copyright 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  1. Clinical utility of the DSM-5 alternative model for borderline personality disorder: Differential diagnostic accuracy of the BFI, SCID-II-PQ, and PID-5.

    Science.gov (United States)

    Fowler, J Christopher; Madan, Alok; Allen, Jon G; Patriquin, Michelle; Sharp, Carla; Oldham, John M; Frueh, B Christopher

    2018-01-01

    With the publication of DSM 5 alternative model for personality disorders it is critical to assess the components of the model against evidence-based models such as the five factor model and the DSM-IV-TR categorical model. This study explored the relative clinical utility of these models in screening for borderline personality disorder (BPD). Receiver operator characteristics and diagnostic efficiency statistics were calculated for three personality measures to ascertain the relative diagnostic efficiency of each measure. A total of 1653 adult inpatients at a specialist psychiatric hospital completed SCID-II interviews. Sample 1 (n=653) completed the SCID-II interviews, SCID-II Questionnaire (SCID-II-PQ) and the Big Five Inventory (BFI), while Sample 2 (n=1,000) completed the SCID-II interviews, Personality Inventory for DSM5 (PID-5) and the BFI. BFI measure evidenced moderate accuracy for two composites: High Neuroticism+ low agreeableness composite (AUC=0.72, SE=0.01, ptrait constellation for diagnosing BPD. Limitations of the study include the single inpatient setting and use of two discrete samples to assess PID-5 and SCID-II-PQ. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Crowdsourcing as a novel technique for retinal fundus photography classification: analysis of images in the EPIC Norfolk cohort on behalf of the UK Biobank Eye and Vision Consortium.

    Science.gov (United States)

    Mitry, Danny; Peto, Tunde; Hayat, Shabina; Morgan, James E; Khaw, Kay-Tee; Foster, Paul J

    2013-01-01

    Crowdsourcing is the process of outsourcing numerous tasks to many untrained individuals. Our aim was to assess the performance and repeatability of crowdsourcing for the classification of retinal fundus photography. One hundred retinal fundus photograph images with pre-determined disease criteria were selected by experts from a large cohort study. After reading brief instructions and an example classification, we requested that knowledge workers (KWs) from a crowdsourcing platform classified each image as normal or abnormal with grades of severity. Each image was classified 20 times by different KWs. Four study designs were examined to assess the effect of varying incentive and KW experience in classification accuracy. All study designs were conducted twice to examine repeatability. Performance was assessed by comparing the sensitivity, specificity and area under the receiver operating characteristic curve (AUC). Without restriction on eligible participants, two thousand classifications of 100 images were received in under 24 hours at minimal cost. In trial 1 all study designs had an AUC (95%CI) of 0.701(0.680-0.721) or greater for classification of normal/abnormal. In trial 1, the highest AUC (95%CI) for normal/abnormal classification was 0.757 (0.738-0.776) for KWs with moderate experience. Comparable results were observed in trial 2. In trial 1, between 64-86% of any abnormal image was correctly classified by over half of all KWs. In trial 2, this ranged between 74-97%. Sensitivity was ≥ 96% for normal versus severely abnormal detections across all trials. Sensitivity for normal versus mildly abnormal varied between 61-79% across trials. With minimal training, crowdsourcing represents an accurate, rapid and cost-effective method of retinal image analysis which demonstrates good repeatability. Larger studies with more comprehensive participant training are needed to explore the utility of this compelling technique in large scale medical image analysis.

  3. Biomarkers improve mortality prediction by prognostic scales in community-acquired pneumonia.

    Science.gov (United States)

    Menéndez, R; Martínez, R; Reyes, S; Mensa, J; Filella, X; Marcos, M A; Martínez, A; Esquinas, C; Ramirez, P; Torres, A

    2009-07-01

    Prognostic scales provide a useful tool to predict mortality in community-acquired pneumonia (CAP). However, the inflammatory response of the host, crucial in resolution and outcome, is not included in the prognostic scales. The aim of this study was to investigate whether information about the initial inflammatory cytokine profile and markers increases the accuracy of prognostic scales to predict 30-day mortality. To this aim, a prospective cohort study in two tertiary care hospitals was designed. Procalcitonin (PCT), C-reactive protein (CRP) and the systemic cytokines tumour necrosis factor alpha (TNFalpha) and interleukins IL6, IL8 and IL10 were measured at admission. Initial severity was assessed by PSI (Pneumonia Severity Index), CURB65 (Confusion, Urea nitrogen, Respiratory rate, Blood pressure, > or = 65 years of age) and CRB65 (Confusion, Respiratory rate, Blood pressure, > or = 65 years of age) scales. A total of 453 hospitalised CAP patients were included. The 36 patients who died (7.8%) had significantly increased levels of IL6, IL8, PCT and CRP. In regression logistic analyses, high levels of CRP and IL6 showed an independent predictive value for predicting 30-day mortality, after adjustment for prognostic scales. Adding CRP to PSI significantly increased the area under the receiver operating characteristic curve (AUC) from 0.80 to 0.85, that of CURB65 from 0.82 to 0.85 and that of CRB65 from 0.79 to 0.85. Adding IL6 or PCT values to CRP did not significantly increase the AUC of any scale. When using two scales (PSI and CURB65/CRB65) and CRP simultaneously the AUC was 0.88. Adding CRP levels to PSI, CURB65 and CRB65 scales improves the 30-day mortality prediction. The highest predictive value is reached with a combination of two scales and CRP. Further validation of that improvement is needed.

  4. Evaluation of fasting state-/oral glucose tolerance test-derived measures of insulin release for the detection of genetically impaired β-cell function.

    Directory of Open Access Journals (Sweden)

    Silke A Herzberg-Schäfer

    Full Text Available BACKGROUND: To date, fasting state- and different oral glucose tolerance test (OGTT-derived measures are used to estimate insulin release with reasonable effort in large human cohorts required, e.g., for genetic studies. Here, we evaluated twelve common (or recently introduced fasting state-/OGTT-derived indices for their suitability to detect genetically determined β-cell dysfunction. METHODOLOGY/PRINCIPAL FINDINGS: A cohort of 1364 White European individuals at increased risk for type 2 diabetes was characterized by OGTT with glucose, insulin, and C-peptide measurements and genotyped for single nucleotide polymorphisms (SNPs known to affect glucose- and incretin-stimulated insulin secretion. One fasting state- and eleven OGTT-derived indices were calculated and statistically evaluated. After adjustment for confounding variables, all tested SNPs were significantly associated with at least two insulin secretion measures (p≤0.05. The indices were ranked according to their associations' statistical power, and the ranks an index obtained for its associations with all the tested SNPs (or a subset were summed up resulting in a final ranking. This approach revealed area under the curve (AUC(Insulin(0-30/AUC(Glucose(0-30 as the best-ranked index to detect SNP-dependent differences in insulin release. Moreover, AUC(Insulin(0-30/AUC(Glucose(0-30, corrected insulin response (CIR, AUC(C-Peptide(0-30/AUC(Glucose(0-30, AUC(C-Peptide(0-120/AUC(Glucose(0-120, two different formulas for the incremental insulin response from 0-30 min, i.e., the insulinogenic indices (IGI(2 and IGI(1, and insulin 30 min were significantly higher-ranked than homeostasis model assessment of β-cell function (HOMA-B; p<0.05. AUC(C-Peptide(0-120/AUC(Glucose(0-120 was best-ranked for the detection of SNPs involved in incretin-stimulated insulin secretion. In all analyses, HOMA-β displayed the highest rank sums and, thus, scored last. CONCLUSIONS/SIGNIFICANCE: With AUC(Insulin(0

  5. Artificial intelligence techniques applied to the development of a decision-support system for diagnosing celiac disease.

    Science.gov (United States)

    Tenório, Josceli Maria; Hummel, Anderson Diniz; Cohrs, Frederico Molina; Sdepanian, Vera Lucia; Pisa, Ivan Torres; de Fátima Marin, Heimar

    2011-11-01

    Celiac disease (CD) is a difficult-to-diagnose condition because of its multiple clinical presentations and symptoms shared with other diseases. Gold-standard diagnostic confirmation of suspected CD is achieved by biopsying the small intestine. To develop a clinical decision-support system (CDSS) integrated with an automated classifier to recognize CD cases, by selecting from experimental models developed using intelligence artificial techniques. A web-based system was designed for constructing a retrospective database that included 178 clinical cases for training. Tests were run on 270 automated classifiers available in Weka 3.6.1 using five artificial intelligence techniques, namely decision trees, Bayesian inference, k-nearest neighbor algorithm, support vector machines and artificial neural networks. The parameters evaluated were accuracy, sensitivity, specificity and area under the ROC curve (AUC). AUC was used as a criterion for selecting the CDSS algorithm. A testing database was constructed including 38 clinical CD cases for CDSS evaluation. The diagnoses suggested by CDSS were compared with those made by physicians during patient consultations. The most accurate method during the training phase was the averaged one-dependence estimator (AODE) algorithm (a Bayesian classifier), which showed accuracy 80.0%, sensitivity 0.78, specificity 0.80 and AUC 0.84. This classifier was integrated into the web-based decision-support system. The gold-standard validation of CDSS achieved accuracy of 84.2% and k=0.68 (pdiagnosis. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Z-burst scenario for the highest energy cosmic rays

    International Nuclear Information System (INIS)

    Fodor, Z.

    2002-10-01

    The origin of highest energy cosmic rays is yet unknown. An appealing possibility is the so-called Z-burst scenario, in which a large fraction of these cosmic rays are decay products of Z bosons produced in the scattering of ultrahigh energy neutrinos on cosmological relic neutrinos. The comparison between the observed and predicted spectra constrains the mass of the heaviest neutrino. The required neutrino mass is fairly robust against variations of the presently unknown quantities, such as the amount of relic neutrino clustering, the universal photon radio background and the extragalactic magnetic field. Considering different possibilities for the ordinary cosmic rays the required neutrino masses are determined. In the most plausible case that the ordinary cosmic rays are of extragalactic origin and the universal radio background is strong enough to suppress high energy photons, the required neutrino mass is 0.08 eV ≤ m ν ≤ 0.40 eV. The required ultrahigh energy neutrino flux should be detected in the near future by experiments such as AMANDA, RICE or the Pierre Auger Observatory. (orig.)

  7. C2 (2-h) levels are not superior to trough levels as estimates of the area under the curve in tacrolimus-treated renal-transplant patients

    DEFF Research Database (Denmark)

    Jørgensen, Kaj; Povlsen, Johan; Madsen, Søren

    2002-01-01

    and AUC by Pearson's correlation coefficient, and pairs of correlation coefficients were compared by an asymptotic Wald-type test. RESULTS: AUC varied five-fold despite near-equal dosing. Pearson's correlation coefficient for trough level, 1, 2, 3, 4, and 6 h were 0.84, 0.60, 0.81, 0.95, 0.95, and 0.......94 on day 3 and 0.94, 0.69, 0.92, 0.96, 0.94, 0.92 on day 14. Three-, 4- and 6-h levels had significantly higher correlation coefficients compared to trough, 1- and 2-h levels. One-hour samples had significantly lower correlation coefficients compared to all other sampling times on day 14. The patient...... with the highest AUC developed nephrotoxicity despite trough levels in the desired range. CONCLUSIONS: Two-hour levels are not superior to trough levels in tacrolimus-treated renal transplant patients. Despite good correlation between trough level and AUC, some patients may still receive nephrotoxic doses despite...

  8. Eyebrow hairs from actinic keratosis patients harbor the highest number of cutaneous human papillomaviruses

    Science.gov (United States)

    2013-01-01

    Background Cutaneous human papillomavirus (HPV) infections seem to be associated with the onset of actinic keratosis (AK). This study compares the presence of cutaneous HPV types in eyebrow hairs to those in tissues of normal skin and skin lesions of 75 immunocompetent AK patients. Methods Biopsies from AK lesions, normal skin and plucked eyebrow hairs were collected from each patient. DNA from these specimens was tested for the presence of 28 cutaneous HPV (betaPV and gammaPV) by a PCR based method. Results The highest number of HPV prevalence was detected in 84% of the eyebrow hairs (63/75, median 6 types) compared to 47% of AK lesions (35/75, median 3 types) (p< 0.001) and 37% of normal skin (28/75, median 4 types) (p< 0.001), respectively. A total of 228 HPV infections were found in eyebrow hairs compared to only 92 HPV infections in AK and 69 in normal skin. In all three specimens HPV20, HPV23 and/or HPV37 were the most prevalent types. The highest number of multiple types of HPV positive specimens was found in 76% of the eyebrow hairs compared to 60% in AK and 57% in normal skin. The concordance of at least one HPV type in virus positive specimens was 81% (three specimens) and 88-93% of all three combinations with two specimens. Conclusions Thus, eyebrow hairs revealed the highest number of cutaneous HPV infections, are easy to collect and are an appropriate screening tool in order to identify a possible association of HPV and AK. PMID:23618013

  9. Development of an Interferometric Phased Array Trigger for Balloon-Borne Detection of the Highest Energy Cosmic Particles

    Science.gov (United States)

    Vieregg, Abigail

    Through high energy neutrino astrophysics, we explore the structure and evolution of the universe in a unique way and learn about the physics inside of astrophysical sources that drives the acceleration of the highest energy particles. Neutrinos travel virtually unimpeded through the universe, making them unique messenger particles for cosmic sources and carrying information about very distant sources that would otherwise be unavailable. The highest energy neutrinos (E>10^{18} eV), created as a by-product of the interaction of the highest energy cosmic rays with the cosmic microwave background, are an important tool for determining the origin of the highest energy cosmic rays and still await discovery. Balloon-borne and ground-based experiments are poised to discover these ultra-high energy (UHE) cosmogenic neutrinos by looking for radio emission from two different types of neutrino interactions: particle cascades induced by neutrinos in glacial ice, and extensive air showers in the atmosphere induced by the charged-particle by-product of tau neutrinos interacting in the earth. These impulsive radio detectors are also sensitive to radio emission from extensive air showers induced directly by UHE cosmic rays. Balloon-borne experiments are especially well-suited for discovering the highest energy neutrinos, and are the only way to probe the high energy cutoff of the sources themselves to reveal the astrophysics that drives the central engines inside the most energetic accelerators in the universe. Balloon platforms offer the chance to monitor extremely large volumes of ice and atmosphere, but with a higher energy threshold compared to ground-based observatories, since the neutrino interaction happens farther from the detector. This tradeoff means that the sensitivity of balloon-borne experiments, such as the Antarctic Impulsive Transient Antenna (ANITA) or the ExaVolt Antenna, is optimized for discovery of the highest energy neutrinos. We are developing an

  10. Accuracies Of Optical Processors For Adaptive Optics

    Science.gov (United States)

    Downie, John D.; Goodman, Joseph W.

    1992-01-01

    Paper presents analysis of accuracies and requirements concerning accuracies of optical linear-algebra processors (OLAP's) in adaptive-optics imaging systems. Much faster than digital electronic processor and eliminate some residual distortion. Question whether errors introduced by analog processing of OLAP overcome advantage of greater speed. Paper addresses issue by presenting estimate of accuracy required in general OLAP that yields smaller average residual aberration of wave front than digital electronic processor computing at given speed.

  11. Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions – Changes in Accuracy over Time

    Science.gov (United States)

    Lebel, Karina; Boissy, Patrick; Hamel, Mathieu; Duval, Christian

    2015-01-01

    Background Interest in 3D inertial motion tracking devices (AHRS) has been growing rapidly among the biomechanical community. Although the convenience of such tracking devices seems to open a whole new world of possibilities for evaluation in clinical biomechanics, its limitations haven’t been extensively documented. The objectives of this study are: 1) to assess the change in absolute and relative accuracy of multiple units of 3 commercially available AHRS over time; and 2) to identify different sources of errors affecting AHRS accuracy and to document how they may affect the measurements over time. Methods This study used an instrumented Gimbal table on which AHRS modules were carefully attached and put through a series of velocity-controlled sustained motions including 2 minutes motion trials (2MT) and 12 minutes multiple dynamic phases motion trials (12MDP). Absolute accuracy was assessed by comparison of the AHRS orientation measurements to those of an optical gold standard. Relative accuracy was evaluated using the variation in relative orientation between modules during the trials. Findings Both absolute and relative accuracy decreased over time during 2MT. 12MDP trials showed a significant decrease in accuracy over multiple phases, but accuracy could be enhanced significantly by resetting the reference point and/or compensating for initial Inertial frame estimation reference for each phase. Interpretation The variation in AHRS accuracy observed between the different systems and with time can be attributed in part to the dynamic estimation error, but also and foremost, to the ability of AHRS units to locate the same Inertial frame. Conclusions Mean accuracies obtained under the Gimbal table sustained conditions of motion suggest that AHRS are promising tools for clinical mobility assessment under constrained conditions of use. However, improvement in magnetic compensation and alignment between AHRS modules are desirable in order for AHRS to reach their

  12. Textural features of {sup 18}F-fluorodeoxyglucose positron emission tomography scanning in diagnosing aortic prosthetic graft infection

    Energy Technology Data Exchange (ETDEWEB)

    Saleem, Ben R.; Zeebregts, Clark J. [University of Groningen, University Medical Center Groningen, Department of Surgery, Division of Vascular Surgery, P.O. Box 30 001, Groningen (Netherlands); Beukinga, Roelof J.; Slart, Riemer H.J.A. [University of Groningen, University Medical Center Groningen, Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University of Twente, Department of Biomedical Photonic Imaging (BMPI), Enschede (Netherlands); Boellaard, Ronald; Glaudemans, Andor W.J.M. [University of Groningen, University Medical Center Groningen, Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Reijnen, Michel M.P.J. [Rijnstate Hospital, Department of Surgery, Arnhem (Netherlands)

    2017-05-15

    The clinical problem in suspected aortoiliac graft infection (AGI) is to obtain proof of infection. Although {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography scanning (PET) has been suggested to play a pivotal role, an evidence-based interpretation is lacking. The objective of this retrospective study was to examine the feasibility and utility of {sup 18}F-FDG uptake heterogeneity characterized by textural features to diagnose AGI. Thirty patients with a history of aortic graft reconstruction who underwent {sup 18}F-FDG PET/CT scanning were included. Sixteen patients were suspected to have an AGI (group I). AGI was considered proven only in the case of a positive bacterial culture. Positive cultures were found in 10 of the 16 patients (group Ia), and in the other six patients, cultures remained negative (group Ib). A control group was formed of 14 patients undergoing {sup 18}F-FDG PET for other reasons (group II). PET images were assessed using conventional maximal standardized uptake value (SUVmax), tissue-to-background ratio (TBR), and visual grading scale (VGS). Additionally, 64 different {sup 18}F-FDG PET based textural features were applied to characterize {sup 18}F-FDG uptake heterogeneity. To select candidate predictors, univariable logistic regression analysis was performed (α = 0.16). The accuracy was satisfactory in case of an AUC > 0.8. The feature selection process yielded the textural features named variance (AUC = 0.88), high grey level zone emphasis (AUC = 0.87), small zone low grey level emphasis (AUC = 0.80), and small zone high grey level emphasis (AUC = 0.81) most optimal for distinguishing between groups I and II. SUVmax, TBR, and VGS were also able to distinguish between these groups with AUCs of 0.87, 0.78, and 0.90, respectively. The textural feature named short run high grey level emphasis was able to distinguish group Ia from Ib (AUC = 0.83), while for the same task the TBR and VGS were not found to be predictive

  13. Textural features of "1"8F-fluorodeoxyglucose positron emission tomography scanning in diagnosing aortic prosthetic graft infection

    International Nuclear Information System (INIS)

    Saleem, Ben R.; Zeebregts, Clark J.; Beukinga, Roelof J.; Slart, Riemer H.J.A.; Boellaard, Ronald; Glaudemans, Andor W.J.M.; Reijnen, Michel M.P.J.

    2017-01-01

    The clinical problem in suspected aortoiliac graft infection (AGI) is to obtain proof of infection. Although "1"8F-fluorodeoxyglucose ("1"8F-FDG) positron emission tomography scanning (PET) has been suggested to play a pivotal role, an evidence-based interpretation is lacking. The objective of this retrospective study was to examine the feasibility and utility of "1"8F-FDG uptake heterogeneity characterized by textural features to diagnose AGI. Thirty patients with a history of aortic graft reconstruction who underwent "1"8F-FDG PET/CT scanning were included. Sixteen patients were suspected to have an AGI (group I). AGI was considered proven only in the case of a positive bacterial culture. Positive cultures were found in 10 of the 16 patients (group Ia), and in the other six patients, cultures remained negative (group Ib). A control group was formed of 14 patients undergoing "1"8F-FDG PET for other reasons (group II). PET images were assessed using conventional maximal standardized uptake value (SUVmax), tissue-to-background ratio (TBR), and visual grading scale (VGS). Additionally, 64 different "1"8F-FDG PET based textural features were applied to characterize "1"8F-FDG uptake heterogeneity. To select candidate predictors, univariable logistic regression analysis was performed (α = 0.16). The accuracy was satisfactory in case of an AUC > 0.8. The feature selection process yielded the textural features named variance (AUC = 0.88), high grey level zone emphasis (AUC = 0.87), small zone low grey level emphasis (AUC = 0.80), and small zone high grey level emphasis (AUC = 0.81) most optimal for distinguishing between groups I and II. SUVmax, TBR, and VGS were also able to distinguish between these groups with AUCs of 0.87, 0.78, and 0.90, respectively. The textural feature named short run high grey level emphasis was able to distinguish group Ia from Ib (AUC = 0.83), while for the same task the TBR and VGS were not found to be predictive. SUVmax was found predictive

  14. Role of 11C-choline positron emission tomography/computed tomography in evaluating patients affected by prostate cancer with suspected relapse due to prostate-specific antigen elevation

    International Nuclear Information System (INIS)

    Bertagna, F.; Bosio, G.; Abuhilal, M.

    2011-01-01

    The aim of this study was to evaluate the accuracy of 11 C-choline positron emission tomography/computed tomography (PET/CT) in restaging patients affected by prostate cancer and suspected relapse due to prostate-specific antigen (PSA) increase. We also aimed to determine a PSA cutoff that is most suited to the study in terms of best compromise between sensitivity and specificity. Secondary endpoints were a comparison between 11 C-choline PET/CT and histological results, clinical findings, and radiological imaging (CT and magnetic resonance imaging). We retrospectively evaluated 210 patients (median±standard deviation (SD) age 70±7 years) affected by prostate cancer who underwent 11 C-choline PET/CT. 11 C-choline PET/CT imaging was positive in 116 (55.2%) patients and negative in 94 (44.8%). Receiver operating characteristic (ROC) analysis showed that the highest accuracy (sensitivity 76.8%, specificity 92.5%) for the whole population was achieved when the PSA level of 1.26 ng/ml level was used as the cutoff value for interpreting the results (P=0.0001 and the area under the ROC curve area under the curve (AUC)=0.897). For patients treated with surgery or surgery plus radiotherapy the cutoff was 0.81 ng/ml (sensitivity 73.2%, specificity 86.1%). For patients treated with radiotherapy alone, the cutoff was 2.0 ng/ml (sensitivity 81.8%, specificity 92.9%). Our results indicate that 11 C-choline PET/CT is a useful diagnostic tool in patients affected by prostate cancer and a relapsed PSA level. The highest accuracy for all patients is obtained with a PSA cutoff level of 1.26 ng/ml, above which the imaging study is performed (0.81 ng/ml for patients treated with surgery or surgery plus radiotherapy and 2.0 ng/ml for patients treated with radiotherapy alone). (author)

  15. Accuracies of genomic breeding values in American Angus beef cattle using K-means clustering for cross-validation

    Directory of Open Access Journals (Sweden)

    Saatchi Mahdi

    2011-11-01

    of genetic merit can be produced in beef cattle at a young age but the recurrent inclusion of genotyped sires in retraining analyses will be necessary to routinely produce for the industry the direct genomic values with the highest accuracy.

  16. Development and validation of prediction models for endometrial cancer in postmenopausal bleeding.

    Science.gov (United States)

    Wong, Alyssa Sze-Wai; Cheung, Chun Wai; Fung, Linda Wen-Ying; Lao, Terence Tzu-Hsi; Mol, Ben Willem J; Sahota, Daljit Singh

    2016-08-01

    To develop and assess the accuracy of risk prediction models to diagnose endometrial cancer in women having postmenopausal bleeding (PMB). A retrospective cohort study of 4383 women in a One-stop PMB clinic from a university teaching hospital in Hong Kong. Clinical risk factors, transvaginal ultrasonic measurement of endometrial thickness (ET) and endometrial histology were obtained from consecutive women between 2002 and 2013. Two models to predict risk of endometrial cancer were developed and assessed, one based on patient characteristics alone and a second incorporated ET with patient characteristics. Endometrial histology was used as the reference standard. The split-sample internal validation and bootstrapping technique were adopted. The optimal threshold for prediction of endometrial cancer by the final models was determined using a receiver-operating characteristics (ROC) curve and Youden Index. The diagnostic gain was compared to a reference strategy of measuring ET only by comparing the AUC using the Delong test. Out of 4383 women with PMB, 168 (3.8%) were diagnosed with endometrial cancer. ET alone had an area under curve (AUC) of 0.92 (95% confidence intervals [CIs] 0.89-0.94). In the patient characteristics only model, independent predictors of cancer were age at presentation, age at menopause, body mass index, nulliparity and recurrent vaginal bleeding. The AUC and Youdens Index of the patient characteristic only model were respectively 0.73 (95% CI 0.67-0.80) and 0.72 (Sensitivity=66.5%; Specificity=68.9%; +ve LR=2.14; -ve LR=0.49). ET, age at presentation, nulliparity and recurrent vaginal bleeding were independent predictors in the patient characteristics plus ET model. The AUC and Youdens Index of the patient characteristic plus ET model where respectively 0.92 (95% CI 0.88-0.96) and 0.71 (Sensitivity=82.7%; Specificity=88.3%; +ve LR=6.38; -ve LR=0.2). Comparison of AUC indicated that a history alone model was inferior to a model using ET alone

  17. Optimizing Distributed Machine Learning for Large Scale EEG Data Set

    Directory of Open Access Journals (Sweden)

    M Bilal Shaikh

    2017-06-01

    Full Text Available Distributed Machine Learning (DML has gained its importance more than ever in this era of Big Data. There are a lot of challenges to scale machine learning techniques on distributed platforms. When it comes to scalability, improving the processor technology for high level computation of data is at its limit, however increasing machine nodes and distributing data along with computation looks as a viable solution. Different frameworks   and platforms are available to solve DML problems. These platforms provide automated random data distribution of datasets which miss the power of user defined intelligent data partitioning based on domain knowledge. We have conducted an empirical study which uses an EEG Data Set collected through P300 Speller component of an ERP (Event Related Potential which is widely used in BCI problems; it helps in translating the intention of subject w h i l e performing any cognitive task. EEG data contains noise due to waves generated by other activities in the brain which contaminates true P300Speller. Use of Machine Learning techniques could help in detecting errors made by P300 Speller. We are solving this classification problem by partitioning data into different chunks and preparing distributed models using Elastic CV Classifier. To present a case of optimizing distributed machine learning, we propose an intelligent user defined data partitioning approach that could impact on the accuracy of distributed machine learners on average. Our results show better average AUC as compared to average AUC obtained after applying random data partitioning which gives no control to user over data partitioning. It improves the average accuracy of distributed learner due to the domain specific intelligent partitioning by the user. Our customized approach achieves 0.66 AUC on individual sessions and 0.75 AUC on mixed sessions, whereas random / uncontrolled data distribution records 0.63 AUC.

  18. Marginal Accuracy and Internal Fit of 3-D Printing Laser-Sintered Co-Cr Alloy Copings.

    Science.gov (United States)

    Kim, Myung-Joo; Choi, Yun-Jung; Kim, Seong-Kyun; Heo, Seong-Joo; Koak, Jai-Young

    2017-01-23

    Laser sintered technology has been introduced for clinical use and can be utilized more widely, accompanied by the digitalization of dentistry and the development of direct oral scanning devices. This study was performed with the aim of comparing the marginal accuracy and internal fit of Co-Cr alloy copings fabricated by casting, CAD/CAM (Computer-aided design/Computer-assisted manufacture) milled, and 3-D laser sintered techniques. A total of 36 Co-Cr alloy crown-copings were fabricated from an implant abutment. The marginal and internal fit were evaluated by measuring the weight of the silicone material, the vertical marginal discrepancy using a microscope, and the internal gap in the sectioned specimens. The data were statistically analyzed by One-way ANOVA (analysis of variance), a Scheffe's test, and Pearson's correlation at the significance level of p = 0.05, using statistics software. The silicone weight was significantly low in the casting group. The 3-D laser sintered group showed the highest vertical discrepancy, and marginal-, occlusal-, and average- internal gaps ( p marginal discrepancy and the internal gap variables ( r = 0.654), except for the silicone weight. In this study, the 3-D laser sintered group achieved clinically acceptable marginal accuracy and internal fit.

  19. Diagnostic accuracy of {sup 18}F amyloid PET tracers for the diagnosis of Alzheimer's disease: a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Morris, Elizabeth; Chalkidou, Anastasia [St Thomas' Hospital, King' s Technology Evaluation Centre, King' s College London, London (United Kingdom); St Thomas' Hospital, Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King' s College London, London (United Kingdom); Hammers, Alexander [St Thomas' Hospital, Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King' s College London, London (United Kingdom); Peacock, Janet; Summers, Jennifer [St Thomas' Hospital, King' s Technology Evaluation Centre, King' s College London, London (United Kingdom); King' s College London, Division of Health and Social Care Research, London (United Kingdom); King' s College London, NIHR Biomedical Research Centre at Guy' s and St Thomas' NHS Foundation Trust, London (United Kingdom); Keevil, Stephen [St Thomas' Hospital, King' s Technology Evaluation Centre, King' s College London, London (United Kingdom); St Thomas' Hospital, Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King' s College London, London (United Kingdom); St Thomas' Hospital, Department of Medical Physics, Guy' s and St Thomas' NHS Foundation Trust, London (United Kingdom)

    2016-02-15

    Imaging or tissue biomarker evidence has been introduced into the core diagnostic pathway for Alzheimer's disease (AD). PET using {sup 18}F-labelled beta-amyloid PET tracers has shown promise for the early diagnosis of AD. However, most studies included only small numbers of participants and no consensus has been reached as to which radiotracer has the highest diagnostic accuracy. First, we performed a systematic review of the literature published between 1990 and 2014 for studies exploring the diagnostic accuracy of florbetaben, florbetapir and flutemetamol in AD. The included studies were analysed using the QUADAS assessment of methodological quality. A meta-analysis of the sensitivity and specificity reported within each study was performed. Pooled values were calculated for each radiotracer and for visual or quantitative analysis by population included. The systematic review identified nine studies eligible for inclusion. There were limited variations in the methods between studies reporting the same radiotracer. The meta-analysis results showed that pooled sensitivity and specificity values were in general high for all tracers. This was confirmed by calculating likelihood ratios. A patient with a positive ratio is much more likely to have AD than a patient with a negative ratio, and vice versa. However, specificity was higher when only patients with AD were compared with healthy controls. This systematic review and meta-analysis found no marked differences in the diagnostic accuracy of the three beta-amyloid radiotracers. All tracers perform better when used to discriminate between patients with AD and healthy controls. The sensitivity and specificity for quantitative and visual analysis are comparable to those of other imaging or biomarker techniques used to diagnose AD. Further research is required to identify the combination of tests that provides the highest sensitivity and specificity, and to identify the most suitable position for the tracer in the

  20. Failure of ETV in patients with the highest ETV success scores.

    Science.gov (United States)

    Gianaris, Thomas J; Nazar, Ryan; Middlebrook, Emily; Gonda, David D; Jea, Andrew; Fulkerson, Daniel H

    2017-09-01

    OBJECTIVE Endoscopic third ventriculostomy (ETV) is a surgical alternative to placing a CSF shunt in certain patients with hydrocephalus. The ETV Success Score (ETVSS) is a reliable, simple method to estimate the success of the procedure by 6 months of postoperative follow-up. The highest score is 90, estimating a 90% chance of the ETV effectively treating hydrocephalus without requiring a shunt. Treatment with ETV fails in certain patients, despite their being the theoretically best candidates for the procedure. In this study the authors attempted to identify factors that further predicted success in patients with the highest ETVSSs. METHODS A retrospective review was performed of all patients treated with ETV at 3 institutions. Demographic, radiological, and clinical data were recorded. All patients by definition were older than 1 year, had obstructive hydrocephalus, and did not have a prior shunt. Failure of ETV was defined as the need for a shunt by 1 year. The ETV was considered a success if the patient did not require another surgery (either shunt placement or a repeat endoscopic procedure) by 1 year. A statistical analysis was performed to identify factors associated with success or failure. RESULTS Fifty-nine patients met the entry criteria for the study. Eleven patients (18.6%) required further surgery by 1 year. All of these patients received a shunt. The presenting symptom of lethargy statistically correlated with success (p = 0.0126, odds ratio [OR] = 0.072). The preoperative radiological finding of transependymal flow (p = 0.0375, OR 0.158) correlated with success. A postoperative larger maximum width of the third ventricle correlated with failure (p = 0.0265). CONCLUSIONS The preoperative findings of lethargy and transependymal flow statistically correlated with success. This suggests that the best candidates for ETV are those with a relatively acute elevation of intracranial pressure. Cases without these findings may represent the failures in this