WorldWideScience

Sample records for higher signal intensity

  1. A study on CT attenuation and MR signal intensity of protein solution

    International Nuclear Information System (INIS)

    Kim, Joung Hae; Choi, Dae Seob; Kim, Soon; Lee, Hyeon Kyeong; Oh, Hyeon Hee; Kim, Seung Hyeon; Lee, Sung Woo; Chang, Kee Hyun; Chung, Jun Ho

    2001-01-01

    To correlate CT attenuation and MR signal intensity with concentration of protein solution. CT and MR examinations of a phantom containing bovine serum albumin solutions of various concentrations ranging from 0 to 55% were performed. CT Hounsfield units(HUs), MR signal intensities, and apparent diffusion coefficients (ADCs) of each albumin solution were measured, and CT HUs and MR signal intensities of the solutions were compared with those of cerebrospinal fluid (CSF), white matter, and cortical gray matter. CT HU increased gradually with increasing albumin concentration. On T1-weighted images(T1WI), signal intensity increased with increasing albumin concentrations of up to 35% but then decreased. On T2-weighted images(T2Wl), gradually decreasing signal intensity and increasing albumin concentration were observed Fluid-attenuated inversion recovery (FLAIR) and diffusion-weighted images (DWls) showed that signal intensity peaked at a concentration of 10% and then gradually decreased. The ADC of the solution gradually decreased as concentration increased. Compared with those of normal brain structures, the CT HUs of solutions at concentrations of over 20% were higher than those of white and gray matter. At T1WI, the signal intensities of 10-45% solutions were similar to or higher than that of the gray matter. At T2Wl, the signal intensities of solutions above 25, 35, and 40% were lower than those of CSF, gray matter, and white matter, respectively. FLAIR images showed that the signal intensities of 5-35% solutions were higher than that of gray matter. The CT attenuation of albumin solution increased gradually with increasing concentration. MR signal intensities peaked at 35% concentration on T1WI and at 10% on FLAIR and DW images, respectively, and then gradually decreased. T2Wl and ADC map images showed gradually decreasing signal intensity and ADC as albumin concentration increased

  2. An experimental study on MRI signal intensity of albumin solution

    International Nuclear Information System (INIS)

    Ahn, In Oak; Chang, Kee Hyun; Han, Moon Hee; Song, Chi Sung; Yeon, Kyung Mo

    1990-01-01

    about 5-15 g/dl concentration and about 15-25 g/dl corresponded to cortical gray matter and periventricular white matter, respectively. On proton density-weighted images, the signal intensities of CSF, cortical gray matter and white matter were all similar and corresponded to albumin concentrations of 0 to 2.5-5.0 g/dl and above 30-35 g/dl concentration. The solution ranging from 5-7.5 g/dl to 25-30 g/dl concentration showed higher signal intensities than brain parenchyma. On T2-weighted images, the signal intensities of the solutions of 0 to 25-30 g/dl concentration appeared identical to that of CSF, and those of higher concentration were similar to those of brain parenchyma. 5. Any difference in signal intensity between 2.0T and 0.5T could not be recognized by visual comparison, although the signal intensities with 0.5T were generally slightly higher on T1-weighted images and slightly lower in proton density-and T2-weighted images. In conclusion, since albumin solution shows variable MR signal intensities, depending on its concentration, and especially shows low signal intensity at the concentration above about 35 g/dl on T1-weighted image, even pure proteinaceous cysts are supposed to have ver variable signal intensities in clinical MR images

  3. Evaluation of signal intensity of various thyroid tissues on MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Baba, Koichiro; Imanishi, Yoshimasa [St. Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine; Igarashi, Ryuukou; Shinagawa, Toshihito

    2001-08-01

    Although normal thyroid mainly consists of thyroid follicles and has large amount of water in them, it shows low signal intensity on T2 weighted MR image. In this paper, we analysed the signal intensity of the thyroid in clinical cases and investigated the relationship between signal intensity and iodine concentration. In forty-one patients who have clinically suspected thyroid diseases, fifty-three MRI examinations of the neck and forty-three thyroid CT examinations were performed. The MR imaging of the neck was performed with T1 weighted image, T2 weighted image, and STIR image. Iodine concentration of the thyroid was measured by the CT software which was originally made by one of the authors (Y.I.). The signal intensity on T2 weighted image negatively correlated with iodine concentration, although there was no relationship between iodine concentration and its signal intensity on T1 weighted image. On T2 weighted image, the intensity of thyroid with high iodine concentration showed a low signal and that of thyroid with low iodine concentration presented a high signal. The thyroid with chronic thyroiditis showed higher signal intensity than normal thyroid and adenmatous goiter on T2 weighted image and STIR image. On T2 weighted image and STIR image, the signal intensity of any thyroid nodules were higher than that of normal thyroid. In addition, follicular adenoma and partially malignant nodules showed a higher signal intensity than thyroid carcinomas. According to previous reports, decreased iodine concentration in thyroid follicles represents decreased concentration of iodine-binding proteins in follicles as well as decreased volume of follicular content in the thyroid. On MR imaging, very high concentration of protein in water solution does not only cause shortening of T1 relaxation time but also shortening of T2 relaxation time resulting in low signal intensity. In the present study, our data seem to suggest that very high concentration of iodine

  4. Evaluation of signal intensity of various thyroid tissues on MR imaging

    International Nuclear Information System (INIS)

    Baba, Koichiro; Imanishi, Yoshimasa; Igarashi, Ryuukou; Shinagawa, Toshihito

    2001-01-01

    Although normal thyroid mainly consists of thyroid follicles and has large amount of water in them, it shows low signal intensity on T2 weighted MR image. In this paper, we analysed the signal intensity of the thyroid in clinical cases and investigated the relationship between signal intensity and iodine concentration. In forty-one patients who have clinically suspected thyroid diseases, fifty-three MRI examinations of the neck and forty-three thyroid CT examinations were performed. The MR imaging of the neck was performed with T1 weighted image, T2 weighted image, and STIR image. Iodine concentration of the thyroid was measured by the CT software which was originally made by one of the authors (Y.I.). The signal intensity on T2 weighted image negatively correlated with iodine concentration, although there was no relationship between iodine concentration and its signal intensity on T1 weighted image. On T2 weighted image, the intensity of thyroid with high iodine concentration showed a low signal and that of thyroid with low iodine concentration presented a high signal. The thyroid with chronic thyroiditis showed higher signal intensity than normal thyroid and adenmatous goiter on T2 weighted image and STIR image. On T2 weighted image and STIR image, the signal intensity of any thyroid nodules were higher than that of normal thyroid. In addition, follicular adenoma and partially malignant nodules showed a higher signal intensity than thyroid carcinomas. According to previous reports, decreased iodine concentration in thyroid follicles represents decreased concentration of iodine-binding proteins in follicles as well as decreased volume of follicular content in the thyroid. On MR imaging, very high concentration of protein in water solution does not only cause shortening of T1 relaxation time but also shortening of T2 relaxation time resulting in low signal intensity. In the present study, our data seem to suggest that very high concentration of iodine

  5. Towards higher intensities

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Over the past 2 weeks, commissioning of the machine protection system has advanced significantly, opening up the possibility of higher intensity collisions at 3.5 TeV. The intensity has been increased from 2 bunches of 1010 protons to 6 bunches of 2x1010 protons. Luminosities of 6x1028 cm-2s-1 have been achieved at the start of fills, a factor of 60 higher than those provided for the first collisions on 30 March.   The recent increase in LHC luminosity as recorded by the experiments. (Graph courtesy of the experiments and M. Ferro-Luzzi) To increase the luminosity further, the commissioning crews are now trying to push up the intensity of the individual proton bunches. After the successful injection of nominal intensity bunches containing 1.1x1011 protons, collisions were subsequently achieved at 450 GeV with these intensities. However, half-way through the first ramping of these nominal intensity bunches to 3.5 TeV on 15 May, a beam instability was observed, leading to partial beam loss...

  6. High signal intensity of fat on fast spin echo imaging

    International Nuclear Information System (INIS)

    Ogura, Akio; Yamazaki, Masaru; Hongoh, Takaharu; Inoue, Hiroshi; Ishikuro, Akihiro

    2000-01-01

    The fast spin echo (FSE) technique of producing T 2 -weighted images in greatly reduced imaging times has recently been used for routine clinical study. FSE images show contrast that is very similar in most tissues to that of conventional SE images. However, fat shows a high signal intensity that is influenced by j-coupling and the magnetization transfer effect. The purpose of this study was to assess whether the higher signal intensity of fat is different among MRI systems and to examine the effects of j-coupling and magnetization transfer on the high signal intensity of fat on FSE. The contrast in signal intensity between fat and water was measured for various echo train lengths (ETL) with and without multislicing on FSE using a contrast phantom. Measurements were obtained with four different MRI systems. In addition, the effective T 2 values of fat were calculated for the above conditions. Results indicated that contrast for fat and water was reduced with increased ETL and by using multislicing and was different among the four MRI systems. The effective T 2 values of fat were extended for increased ETL and were not dependent on multislicing. They also differed among the four MRI systems. The extent of effective T 2 values was affected by j-coupling. In this study, it was indicated that the degree of the high signal intensity of fat on FSE differed for different MRI systems. In addition, the reasons for the high signal intensity of fat on FSE were related to the effects of j-coupling and magnetization transfer. (author)

  7. Suitability of cerebrospinal fluid as a signal-intensity reference on MRI: evaluation of signal-intensity variations in the lumbosacral dural sac

    International Nuclear Information System (INIS)

    Luoma, E.K.; Luukkonen, R.; Riihimaeki, H.A.; Raininko, R.; Manninen, H.I.; Nummi, P.J.

    1997-01-01

    The suitability of the cerebrospinal fluid (CSF) in the lumbosacral dural sac as an internal signal-intensity reference was studied on magnetic resonance imaging (MRI) of the lumbar spine using a surface coil and motion artefact suppression technique. A signal-intensity reference is needed when signal is compared between images, studies or subjects. Homogeneity of the CSF was estimated visually on T2-weighted images of 60 subjects at 1.5 T and of another 60 subjects at 0.1 T. Spines with a severely narrowed dural sac or marked scoliosis were excluded from the study to avoid partial volume effect. CSF was homogeneous in 82% and 73% of the examinations at 1.5 T and 0.1 T, respectively. The type and location of the local inhomogeneities did not relate to local narrowings of the dural sac. The signal intensity of CSF was measured in 108 examinations at 0.1 T after correcting the spatially-dependent signal-intensity nonuniformities with a phantom-based method. The signal-intensity difference between the CSF in the upper and lower lumbar dural sac was less than 10% in 73% of the examinations. The CSF in the lumbosacral dural sac can be a useful signal-intensity reference for estimation of the signal of the adjacent structures in patients without severe narrowing of the dural sac or marked scoliosis. It may contribute to assessing spinal disease processes. (orig.). With 1 fig., 3 tabs

  8. Intensity and directionality of bat echolocation signals

    DEFF Research Database (Denmark)

    Jakobsen, Lasse; Brinkløv, Signe; Surlykke, Annemarie

    2013-01-01

    will increase signal directionality in the field along with intensity thus increasing sonar range. During the last phase of prey pursuit, vespertilionid bats broaden their echolocation beam considerably, probably to counter evasive maneuvers of eared prey. We highlight how multiple call parameters (frequency......The paper reviews current knowledge of intensity and directionality of bat echolocation signals. Recent studies have revealed that echolocating bats can be much louder than previously believed. Bats previously dubbed "whispering" can emit calls with source levels up to 110 dB SPL at 10 cm......, duration, intensity, and directionality of echolocation signals) in unison define the search volume probed by bats and in turn how bats perceive their surroundings. Small changes to individual parameters can, in combination, drastically change the bat's perception, facilitating successful navigation...

  9. MR imaging of lumbar spondylolysis: signal intensity change in the pars interarticularis and adjacent structures

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Suk Whan; Lee, Ghi Jai; Shim, Jae Chan; Kim, Ho Kyun [Inje Univ. College of Medicine, Kimhae (Korea, Republic of)

    2001-05-01

    To assess changes in MR signal intensity in the pars interarticularis and adjacent structures in patients with lumbar spondylolysis. The MR images of 36 patients with lumbar spondylolysis, confirmed by plain radiographs, were retrospectively analyzed. Using a 1.0T unit, we evaluated the signal intensity of a total of 216 parts interarticulares and adjacent structures from L3 to L5, as seen on sagittal images, and differences between areas with and without spondylolysis. The signal intensity of T1-and T2-weighted images was graded 0(more hypointense than spinal body), 1(as isointense as spinal body), 2(more hyperintense than spinal body and more hypointense than epidural fat), or 3(as isointense as epidural fat). Signal intensity change in endplates and degree of spondylolisthesis were analyzed, and the relationship between these factors was determined. Spondylolysis was noted at L5 in 61 cases, at L4 in 22, and of L3 in no case. In three cases spondylolysis was unilateral, and in the remainder it was bilateral. The degree of signal intensity was the same on T1-and T2-weighted images, and no case was grade 0. Eighty-six of 133 areas without spondylolysis were grade 1, 43 were grade 2, and four were grade 3. In 42 of 47 cases, signal intensity change was localized at pedicles. Among 83 areas with spondylolysis,on the other hand, nine were grade 1, 48 were grade 2, and 26 were grade 3. Signal intensity change was most commonly observed at the pars interarticularis, pedicle, and lamina(50/74)({rho}<0.001). Signal intensity change at the pars interarticularis and adjacent structures was accompanied in most cases by degenerative endplate change(10/11) and spondylolisthesis(11/13)({rho}<0.001). In patients with spondylolysis, signal intensity was frequently higher at the pars interarticularis and adjacent structures, and is thought to have a close relationship with degenerative endplate change and spondylolisthesis. Increases in signal intensity at the pars

  10. MR imaging of lumbar spondylolysis: signal intensity change in the pars interarticularis and adjacent structures

    International Nuclear Information System (INIS)

    Jang, Suk Whan; Lee, Ghi Jai; Shim, Jae Chan; Kim, Ho Kyun

    2001-01-01

    To assess changes in MR signal intensity in the pars interarticularis and adjacent structures in patients with lumbar spondylolysis. The MR images of 36 patients with lumbar spondylolysis, confirmed by plain radiographs, were retrospectively analyzed. Using a 1.0T unit, we evaluated the signal intensity of a total of 216 parts interarticulares and adjacent structures from L3 to L5, as seen on sagittal images, and differences between areas with and without spondylolysis. The signal intensity of T1-and T2-weighted images was graded 0(more hypointense than spinal body), 1(as isointense as spinal body), 2(more hyperintense than spinal body and more hypointense than epidural fat), or 3(as isointense as epidural fat). Signal intensity change in endplates and degree of spondylolisthesis were analyzed, and the relationship between these factors was determined. Spondylolysis was noted at L5 in 61 cases, at L4 in 22, and of L3 in no case. In three cases spondylolysis was unilateral, and in the remainder it was bilateral. The degree of signal intensity was the same on T1-and T2-weighted images, and no case was grade 0. Eighty-six of 133 areas without spondylolysis were grade 1, 43 were grade 2, and four were grade 3. In 42 of 47 cases, signal intensity change was localized at pedicles. Among 83 areas with spondylolysis,on the other hand, nine were grade 1, 48 were grade 2, and 26 were grade 3. Signal intensity change was most commonly observed at the pars interarticularis, pedicle, and lamina(50/74)(ρ<0.001). Signal intensity change at the pars interarticularis and adjacent structures was accompanied in most cases by degenerative endplate change(10/11) and spondylolisthesis(11/13)(ρ<0.001). In patients with spondylolysis, signal intensity was frequently higher at the pars interarticularis and adjacent structures, and is thought to have a close relationship with degenerative endplate change and spondylolisthesis. Increases in signal intensity at the pars interarticularis and

  11. MR signal intensity of the perirolandic cirtex in the neonate and infant

    International Nuclear Information System (INIS)

    Korogi, Y.; Takahashi, M.; Sumi, M.; Hirai, T,; Sakamoto, Y.; Ikushima, I.; Miyayama, H.

    1996-01-01

    Our purpose was to study the magnetic resonance (MR) signal intensity of the perirolandic gyri perinatally and to correlate it with the histological findings in formalin-fixed brains, focusing on myelination. MRI of 20 neurologically normal neonates and infants, of 37-64 weeks postconception (PCA), were studied retrospectively. We reviewed four formalin-fixed brains of infants 37-46 weeks PCA microscopically. The posterior cortex of the precentral gyrus (P-PRE) and the anterior cortex of the postcentral gyrus (A-PST) had different signal intensity form the adjacent surrounding cortex. On T1-weighted images P-PRE and A-PST gave higher signal 41-44 weeks PCA; on T2-weighted images, they gave lower signal 37-51 weeks PCA. Histological examination revealed very little myelination of the nerve fibres within both the P-PRE and the A-PST, while considerable myelination was present in the internal capsule and central corona radiata. The changes in signal intensity in the perirolandic gyri may reflect not only the degree of myelination but also the more advanced development of the nerve cells, associated with rapid proliferation and formation of oligodendroglial cells, synapses and dendrites. They could be another important landmark for brain maturation. (orig.)

  12. Signal intensity enhancement of laser ablated volume holograms

    Science.gov (United States)

    Versnel, J. M.; Williams, C.; Davidson, C. A. B.; Wilkinson, T. D.; Lowe, C. R.

    2017-11-01

    Conventional volume holographic gratings (VHGs) fabricated in photosensitive emulsions such as gelatin containing silver salts enable the facile visualization of the holographic image in ambient lighting. However, for the fabrication of holographic sensors, which require more defined and chemically-functionalised polymer matrices, laser ablation has been introduced to create the VHGs and thereby broaden their applications, although the replay signal can be challenging to detect in ambient lighting. When traditional photochemical bleaching solutions used to reduce light scattering and modulate refractive index within the VHG are applied to laser ablated volume holographic gratings, these procedures decrease the holographic peak intensity. This is postulated to occur because both light and dark fringes contain a proportion of metal particles, which upon solubilisation are converted immediately to silver iodide, yielding no net refractive index modulation. This research advances a hypothesis that the reduced intensity of holographic replay signals is linked to a gradient of different sized metal particles within the emulsion, which reduces the holographic signal and may explain why traditional bleaching processes result in a reduction in intensity. In this report, a novel experimental protocol is provided, along with simulations based on an effective medium periodic 1D stack, that offers a solution to increase peak signal intensity of holographic sensors by greater than 200%. Nitric acid is used to etch the silver nanoparticles within the polymer matrix and is thought to remove the smaller particles to generate more defined metal fringes containing a soluble metal salt. Once the grating efficiency has been increased, this salt can be converted to a silver halide, to modulate the refractive index and increase the intensity of the holographic signal. This new protocol has been tested in a range of polymer chemistries; those containing functional groups that help to

  13. High signal intensity of anterior pituitary gland on T1-weighted MR imaging in normal postpartum women

    International Nuclear Information System (INIS)

    Kim, Myung Soon; Yang, Hak Seok; Chung, In Bai

    1995-01-01

    The purpose of this study is to evaluate the signal intensity and size of anterior pituitary gland in postpartum women, and to compare with those of control group. In 34 postpartum women (18-43 years, mean: 27 years) and another 35 control nonpregnant women (20-29 years, mean: 24 years), midsagittal T1-weighted MR images were obtained. The signal intensity and height of the anterior pituitary gland were compared between the post-partum and normal control groups. In postpartum women, the signal intensity of the anterior pituitary gland relative to the pons was higher than that of the control group. Pituitary gland height of postpartum women was higher (5-11. 8mm, mean 8.18 ± 1.8mm) than that of control group (2-9mm, mean: 6.2 ± 1.7mm). It is concluded that the hyperintensity of the anterior pituitary gland on T1-weighted image is a normal finding in postpartum women, which is useful in differentiation from pituitary abnormality

  14. High signal intensity of anterior pituitary gland on T1-weighted MR imaging in normal postpartum women

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myung Soon; Yang, Hak Seok; Chung, In Bai [Wonju College of Medicine, Yonsei University, Wonju (Korea, Republic of)

    1995-01-15

    The purpose of this study is to evaluate the signal intensity and size of anterior pituitary gland in postpartum women, and to compare with those of control group. In 34 postpartum women (18-43 years, mean: 27 years) and another 35 control nonpregnant women (20-29 years, mean: 24 years), midsagittal T1-weighted MR images were obtained. The signal intensity and height of the anterior pituitary gland were compared between the post-partum and normal control groups. In postpartum women, the signal intensity of the anterior pituitary gland relative to the pons was higher than that of the control group. Pituitary gland height of postpartum women was higher (5-11. 8mm, mean 8.18 {+-} 1.8mm) than that of control group (2-9mm, mean: 6.2 {+-} 1.7mm). It is concluded that the hyperintensity of the anterior pituitary gland on T1-weighted image is a normal finding in postpartum women, which is useful in differentiation from pituitary abnormality.

  15. Estimation of signal intensity for online measurement X-ray pinhole camera

    International Nuclear Information System (INIS)

    Dong Jianjun; Liu Shenye; Yang Guohong; Yu Yanning

    2009-01-01

    The signal intensity was estimated for on-line measurement X-ray pinhole camera with CCD as measurement equipment. The X-ray signal intensity counts after the attenuation of thickness-varied Be filters and different material flat mirrors respectively were estimated using the energy spectrum of certain laser prototype and the quantum efficiency curve of PI-SX1300 CCD camera. The calculated results indicate that Be filters no thicker than 200 μm can only reduce signal intensity by one order of magnitude, and so can Au flat mirror with 3 degree incident angle, Ni, C and Si flat mirrors with 5 degree incident angle,but the signal intensity counts for both attenuation methods are beyond the saturation counts of the CCD camera. We also calculated the attenuation of signal intensity for different thickness Be filters combined with flat mirrors, indicates that the combination of Be filters with the thickness between 20 and 40 μm and Au flat mirror with 3 degree incident angle or Ni flat mirror with 5 degree incident angle is a good choice for the attenuation of signal intensity. (authors)

  16. Relative signal intensity changes of frontal and occipital white matters on T 2 weighted axial MR image : correlation with age

    International Nuclear Information System (INIS)

    Kim, You Me; Kim, Seung Cheol

    1998-01-01

    The purpose of this study is to assess relative signal intensity changes in frontal and occipital white matter with age, as seen on T 2 weighted axial MR images. Thirty eight normal adults (20-29 years old) and 114 children (0-11 years old) were investigated. All had nonspecific neurologic symptoms and their MR images, obtained using a 1.5 T system (Signa, GE Medical Systems, Milwaukee, U.S.A.), appeared to be normal. The signal intensities of frontal and occipital white matter were evaluated on T2 weighted axial images at the level of the foramen of Monro. When the signal intensity of white matter was higher than that of gray matter, grade 0 was assigned; when the opposite situation pertained, this was graded I - III. Grade I indicated that the signal intensity of occipital white matter was lower than that of frontal white matter; grade II, that the signal intensity of white matter of both lobes was similar. When the signal intensity of frontal white matter was lower than that of occipital age, and by one year after 2 years of age, and then determined grade according to age, age distribution according to grade, and the ages at which signal intensities were similar to those of adults. On T2-weighted MR images, the signal intensity of frontal white matter ultimately shows a lower signal intensity than that of occipital white matter. (author). 11 refs., 6 figs

  17. Analysis of small-signal intensity modulation of semiconductor ...

    Indian Academy of Sciences (India)

    This paper demonstrates theoretical characterization of intensity modulation of semiconductor lasers (SL's). The study is based on a small-signal model to solve the laser rate equations taking into account suppression of optical gain. Analytical forms of the small-signal modulation response and modulation bandwidth are ...

  18. MRI evaluation of cranial bone marrow signal intensity and thickness in chronic anemia

    International Nuclear Information System (INIS)

    Yildirim, Tulin; Agildere, A. Muhtesem; Oguzkurt, Levent; Barutcu, Ozlem; Kizilkilic, Osman; Kocak, Rikkat; Alp Niron, Emin

    2005-01-01

    Background and purpose: The aim is to assess the magnetic resonance imaging (MRI) findings for cranial bone marrow (CBM) signal intensity and thickness in patients with chronic anemia and compared these with findings in healthy subjects. We also investigated the relationships between CBM changes and age, type of anemia (hemolytic versus non-hemolytic), and severity of anemia. Methods: We quantitatively evaluated CBM signal intensity and thickness on images from 40 patients with chronic anemia (20 with congenital hemolytic anemia (HA) and 20 with acquired anemia) and compared these to findings in 28 healthy subjects. The intensity of CBM relative to scalp, white matter (WM), gray matter (GM), and muscle intensity was also investigated in patients and subjects in the control group. The sensitivity and specificity of CBM hypointense to GM and CBM hypointense to WM as markers of anemia were evaluated. Relationships between age and CBM thickness/intensity, and between anemia severity (hemoglobin (Hb) level) and CBM thickness/intensity were evaluated. Results: Cranial bone marrow signal intensity was lower in the chronic anemia patients than in the controls (P 0.05 for both). There were no correlations between age and CBM intensity or thickness, or between anemia severity and CBM intensity or thickness. Conclusion: Patients with chronic anemia exhibit lower CBM signal intensity on MRI than healthy subjects. Patients with hemolytic anemia have thicker CBM than patients with non-hemolytic anemia or healthy individuals. Decreased CBM intensity may indicate that the patient has anemia, and increased CBM thickness may specifically point to hemolytic anemia. These MRI findings may signal the need for further evaluation for the clinician

  19. An experimental study on MRI signal intensity vs concentration of water-soluble contrast media

    International Nuclear Information System (INIS)

    Lee, Ghi Jai; Han, Chang Yul; Chang, Kee Hyun; Han, Moon Hee; Han, Man Chung

    1991-01-01

    There has been only one report that water-soluble contrast media containing iodine and used in conventional X -ray radiography reduce T1-and T2-relaxation times. We evaluated the relationship between signal intensity (relative signal intensity to normal saline) and T2-relaxation time of MRI and the concentration of 3 water-soluble contrast media [meglumine ioxithalamate (Telebrix 30), iopromide (Ultravist 300), iotrolan (Isovist 300)] through the phantom study, using both 2.0T and 0.5T MR units. We found that the signal intensity increased significantly on the T1-weighted images as the concentration of contrast media increased. The degree of the increase was larger on 0.5T MR than on 2.0T MR. The signal intensity on proton density image showed no significant difference at various concentrations. However, there were significant decreases of both signal intensity on the T2-weighted images and T2-relaxation time as the concentration of contrast media increased, which was more prominent on 2.0T MR than 0.5T MR. Between the contrast media of the same concentration, there was no significant difference in signal intensity and T2-relaxation time

  20. Histologic correlation of MR signal intensity in parathyroid adenomas

    International Nuclear Information System (INIS)

    Rumancik, W.M.; Khan, A.; Mir, R.N.; Attie, J.N.; Davis, J.E.; Ashtari, M.; Herman, P.G.

    1988-01-01

    The classic MR signal intensity pattern of parathyroid adenoma (PTA) is bright enhancement on T2-weighted images. However, variations in SI pattern have been observed in clinical practice. The purpose of this report is to describe the histologic characteristics of surgically removed PTAs as correlated with their in vivo MR imaging appearance. From May 1987 to April 1988, 51 consecutive patients with primary hyperparathyroidism were evaluated with MR imaging for preoperative localization of PTA. Surgical confirmation was obtained in all patients, with histologic evaluation available in 40. MR imaging was performed on 1.0-T system (Siemens, Magnetom) using a Helmhotz surface coil positioned at the neck. Spin-echo T1-weighted and T2-weighted multisection images were evaluated retrospectively. Signal intensities of PTA, adjacent thyroid, fat, and skeletal muscle were obtained (1) from direct region of interest determinations, and (2) visually as respective relationships of PTA to thyroid, fat, and muscle. Histologic classification was graded for (1) predominant cell type (i.e., chief or oxyphil cells), (2) acinar or solid growth pattern, (3) cystic change, (4) presence or absence of residual fat, (5) cell count per high power field, (6) heterogeneous histology, (7) gland weight, and (8) giant size (≥3 cm). The relationship of MR signal intensity to histology appears multifactorial

  1. A basic characteristic of signal intensity in MRI

    International Nuclear Information System (INIS)

    Doi, Tsukasa

    2009-01-01

    For evaluation of the significance of signal intensity and contrast which determine the MR imaging quality, SNR (signal-to-noise ratio) and CNR (contrast-to-noise ratio) were studied as their respective measures on the cross-talk artifact (CTA), partial volume effect (PVE), intensity of the fast spin echo (SE) imaging and contrast in the 3T field area (Con). The machine used was 3.0T Signa HDx (GE). CTA, the SNR-reducing coherence between neighboring slices at multi-slice imaging, was studied with a series of phantoms of 0.75-4 mm diameter acrylic pins in cupric sulfate solution with various imaging modes and slice numbers to calculate CNR and contrast (C) involving SNR factor. PVE, the determinant of the intensity depending on the mixture of different tissues within a voxel (slice thickness), was studied with similar phantoms to above with 1-12 mm thick slices and different slice gaps to obtain CNR and C. The intensity of fast SE image was studied with phantoms in a brain-equivalent 0.125 mM Gd solution of sealed water, 0.25-0.5mM Gd, butter, salad oil and detergent on magnetization transfer, J-coupling and diffusion. Con in the 3T machine was studied with the same phantoms as above on the image contrasts at the central and peripheral imaging areas and the intensity/contrast changes by different coils. Presented data of above examinations revealed the effects of characteristic of each environmental factor, and of which recognition was concluded necessary to exactly read the obtained images. (K.T.)

  2. Effect of expectation on pain assessment of lower- and higher-intensity stimuli.

    Science.gov (United States)

    Ružić, Valentina; Ivanec, Dragutin; Modić Stanke, Koraljka

    2017-01-01

    Pain modulation via expectation is a well-documented phenomenon. So far it has been shown that expectations about effectiveness of a certain treatment enhance the effectiveness of different analgesics and of drug-free pain treatments. Also, studies demonstrate that people assess same-intensity stimuli differently, depending on the experimentally induced expectations regarding the characteristics of the stimuli. Prolonged effect of expectation on pain perception and possible symmetry in conditions of lower- and higher-intensity stimuli is yet to be studied. Aim of this study is to determine the effect of expectation on the perception of pain experimentally induced by the series of higher- and lower-intensity stimuli. 192 healthy participants were assigned to four experimental groups differing by expectations regarding the intensity of painful stimuli series. Expectations of two groups were congruent with actual stimuli; one group expected and received lower-intensity stimuli and the other expected and received higher-intensity stimuli. Expectations of the remaining two groups were not congruent with actual stimuli; one group expected higher-intensity stimuli, but actually received lower-intensity stimuli while the other group expected lower-intensity stimuli, but in fact received higher-intensity ones. Each group received a series of 24 varied-intensity electrical stimuli rated by the participants on a 30° intensity scale. Expectation manipulation had statistically significant effect on pain intensity assessment. When expecting lower-intensity stimuli, the participants underestimated pain intensity and when expecting higher-intensity stimuli, they overestimated pain intensity. The effect size of expectations upon pain intensity assessment was equal for both lower- and higher-intensity stimuli. The obtained results imply that expectation manipulation can achieve the desired effect of decreasing or increasing both slight and more severe pain for a longer period of

  3. Parenchymal signal intensity in 3-T body MRI of dogs with hematopoietic neoplasia.

    Science.gov (United States)

    Feeney, Daniel A; Sharkey, Leslie C; Steward, Susan M; Bahr, Katherine L; Henson, Michael S; Ito, Daisuke; O'Brien, Timothy D; Jessen, Carl R; Husbands, Brian D; Borgatti, Antonella; Modiano, Jaime F

    2013-04-01

    We performed a preliminary study involving 10 dogs to assess the applicability of body MRI for staging of canine diffuse hematopoietic neoplasia. T1-weighted (before and after intravenous gadolinium), T2-weighted, in-phase, out-of-phase, and short tau inversion recovery pulse sequences were used. By using digital region of interest (ROI) and visual comparison techniques, relative parenchymal organ (medial iliac lymph nodes, liver, spleen, kidney cortex, and kidney medulla) signal intensity was quantified as less than, equal to, or greater than that of skeletal muscle in 2 clinically normal young adult dogs and 10 dogs affected with either B-cell lymphoma (n = 7) or myelodysplastic syndrome (n = 3). Falciform fat and urinary bladder were evaluated to provide additional perspective regarding signal intensity from the pulse sequences. Dogs with nonfocal disease could be distinguished from normal dogs according to both the visual and ROI signal-intensity relationships. In normal dogs, liver signal intensity on the T2-weighted sequence was greater than that of skeletal muscle by using either the visual or ROI approach. However in affected dogs, T2-weighted liver signal intensity was less than that of skeletal muscle by using either the ROI approach (10 of 10 dogs) or the visual approach (9 of 10 dogs). These findings suggest that the comparison of relative signal intensity among organs may have merit as a research model for infiltrative parenchymal disease (ROI approach) or metabolic effects of disease; this comparison may have practical clinical applicability (visual comparison approach) as well.

  4. High signal intensity of the septum pellucidum at MR imaging; Significance in hydrocephalus

    International Nuclear Information System (INIS)

    Yoon, Jeong Hee; Kim, Eun Ha; Chung, Chun Phil; Kim, Chang Soo

    1994-01-01

    To evaluate the significance of high signal intensity of the septum pellucidum in hydrocephalus on proton density-weighted brain MR images. Authors reviewed the MR images of 418 cases of patients with normal (175 case), hydrocephalic(35 cases), atrophic(58 cases), and other groups(150 cases) retrospectively. We analyzed the signal intensity of the septum pellucidum in the normal group and the incidences of high signal intensities of periventricular area of frontal horn of lateral ventricle(area 1), periventricular area except area 1 (area 2), callososeptal area(area 3), and septum pellucidum(area 4) in the normal and abnormal groups. In the normal group, the septum pellucidum was isointense to the head of caudate nucleus on proton density-weighted image. High signal intensity of the septum pellucidum was seen in 31 cases (22 cases of hydrocephalus, 5 cases of brain atrophy, and 4 cases of others), and showed high specificity(91.4%) for hydrocephalus in spite of low sensitivity(62.9%), as compared with periventricular hyperintensities of other areas. High signal intensity of the septum pellucidum on proton density- weighted image may be caused by transependymal CSF migration in the patients with hydrocephalus, and considered as an additional finding of hydrocephalus in the cases of ventriculomegaly

  5. Pedicle marrow signal intensity changes in the lumbar spine: a manifestation of facet degenerative joint disease

    International Nuclear Information System (INIS)

    Morrison, J.L.; Kaplan, P.A.; Dussault, R.G.; Anderson, M.W.

    2000-01-01

    Objective. Signal intensity changes in lumbar pedicles, similar to those described in vertebral body endplates adjacent to degenerated discs, have been described as an ancillary sign of spondylolysis on MRI. The purpose of this study was to determine whether pedicle marrow signal intensity changes also occur in association with facet degenerative joint disease.Design. Eighty-nine lumbar spine MRI examinations without spondylolysis were reviewed for marrow signal intensity changes in pedicles and vertebral bodies as well as for facet degenerative joint disease.Results. Five percent (46/890) of lumbar pedicles in 23 patients had marrow signal intensity changes. Ninety-one percent (42/46) of the abnormal pedicles had adjacent degenerative joint disease of the facets, while only 21% (189/890) of normal pedicles had adjacent facet degenerative joint disease (p<0.001). Eighty-nine percent (41/46) of the pedicles with marrow signal intensity changes had adjacent degenerative disc disease.Conclusions. Pedicle marrow signal intensity changes are not a specific sign of spondylolysis; they are commonly seen with adjacent facet degenerative joint disease in the absence of spondylolysis. Pedicle marrow signal intensity changes are probably a response to abnormal stresses related to abnormal motion or loading caused by the degenerative changes in the spinal segment. (orig.)

  6. Pedicle marrow signal intensity changes in the lumbar spine: a manifestation of facet degenerative joint disease

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, J.L.; Kaplan, P.A.; Dussault, R.G.; Anderson, M.W. [Dept. of Radiology, Univ. of Virginia Health System, Charlottesville, VA (United States)

    2000-12-01

    Objective. Signal intensity changes in lumbar pedicles, similar to those described in vertebral body endplates adjacent to degenerated discs, have been described as an ancillary sign of spondylolysis on MRI. The purpose of this study was to determine whether pedicle marrow signal intensity changes also occur in association with facet degenerative joint disease.Design. Eighty-nine lumbar spine MRI examinations without spondylolysis were reviewed for marrow signal intensity changes in pedicles and vertebral bodies as well as for facet degenerative joint disease.Results. Five percent (46/890) of lumbar pedicles in 23 patients had marrow signal intensity changes. Ninety-one percent (42/46) of the abnormal pedicles had adjacent degenerative joint disease of the facets, while only 21% (189/890) of normal pedicles had adjacent facet degenerative joint disease (p<0.001). Eighty-nine percent (41/46) of the pedicles with marrow signal intensity changes had adjacent degenerative disc disease.Conclusions. Pedicle marrow signal intensity changes are not a specific sign of spondylolysis; they are commonly seen with adjacent facet degenerative joint disease in the absence of spondylolysis. Pedicle marrow signal intensity changes are probably a response to abnormal stresses related to abnormal motion or loading caused by the degenerative changes in the spinal segment. (orig.)

  7. A study on MR signal intensity of calcifications according to calcium concentration and compound

    International Nuclear Information System (INIS)

    Chang, Sun Ae; Kim, Jae Hyoung; Chung, Sung Hoon

    1996-01-01

    The signal of intracranial calcification on magnetic resonance (MR) imaging has been known to be variable. The purpose of this study was to evaluate the MR signal of calcifications according to calcium concentration and compound. T1-weighted, proton density and T2-weighted images were obtained in phantoms with various conposition of calcium carbonate and calcium phosphate. The signal intensities and T1/T2 relaxation times were measured and analyzed according to calcium concentration and compound. The configurations of calcium particles were evaluated by scanning electron microscopy. The signal intensity of calcium carbonate on T1-weighted images gradually decreased as the concentration increased, while that of calcium phosphate showed a biphasic curve with a peak intensity at 0.2g/ml. The signal intensity of both calcium phosphate decreased up to 0.2g/ml and then remained constant. The T2 relaxation time of both calcium compounds decreased in a similar fashion with increasing concentration, Calcium phosphate showed larger surface area on scanning electron microscope. Calcifications show variable MR signal due to difference of T1 and T2 relaxation times according to calcium concentration and compound. Large surface area of calcium particle might cause shortening of T1 relaxation time leading to high signal on T1-weighted image. Understanding of these findings will help interpretation of MR images more precisely

  8. MRI signal intensity as a maker of impairment in incomplete cervical spinal cord injuries

    International Nuclear Information System (INIS)

    Chiba, Hidefumi; Aoki, Haruhito; Hamabe, Masaki; Sasao, Yutaka; Miura, Takehiko

    1998-01-01

    Incomplete cervical spinal cord injuries such as central cord syndrome may result in prolonged spasticity of the limbs, especially disabilities of the upper extremities, even if the patient is able to walk. In this study, relationship between cord impairment and clinical outcome was investigated using MRI. Results showed that small foci of low signal intensity in T 1 -weighted imaging combined with foci of high signal intensity in T 2 -weighted imaging in follow-up MRI are closely related to the severity of sequelae. Small foci of low signal intensity in T 1 -weighted imaging are considered in the literature to indicate myelomalacia or cyst formation with gliosis. (author)

  9. The impact of the amount of intracellular SPIO on MR signal intensity during in vivo tracking of macrophage homing

    International Nuclear Information System (INIS)

    Kim, Dae Yoon; Lee, Jin Seong; Kang, Ju Hee; Sohn, Jin Young; Kim, Sang Tae; Woo, Chul Woong

    2008-01-01

    To determine whether the amount of intracellular superparamagnetic iron oxide (SPIO) in macrophages influences MR signal intensity during in vivo celluar tracking. Peritoneal macrophages harvested from thioglycolate-treated mice were labeled with SPIO using concentrations of 112, 56, and 28 μ gFe/ml, and different incubation times of 3h, 6h, 12h, 24h and 48h, respectively. The iron concentration was quantified with the use of absorption spectrophotometry. Each group of macrophages labeled with different concentrations of SPIO was intravenously injected into 18 mice, after inoculation with S. aureus to the thigh. The relative signal intensity (SI) of the abscess wall (SI of the abscess wall/SI of muscle) was measured on MR and was analyzed by the use of the Kruskal-Wallis test. A higher concentration of SPIO in the labeling solution and a longer incubation time resulted in a higher concentration of SPIO in the macrophages. The relative SI of the abscess wall (0.63 for 112 μ gFe/mL; 0.67 for 56 μ gFe/ml; 0.89 for 28 μ gFe/mL) significantly decreased with an increase of SPIO concentration (κ 2 = 10.53, ρ < 0.005). The amount of intracellular SPIO influences the MR signal intensity by the susceptibility effect and it is recommended to use sufficient iron-oxide label as long as it dose not affect cellular function and viability

  10. MR imaging of the biliary tract with Gd-EOB-DTPA: Effect of liver function on signal intensity

    Energy Technology Data Exchange (ETDEWEB)

    Takao, Hidemasa, E-mail: takaoh-tky@umin.ac.jp [Department of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 (Japan); Akai, Hiroyuki; Tajima, Taku [Department of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 (Japan); Kiryu, Shigeru [Department of Radiology, Institute of Medical Science, University of Tokyo, 74-6-1 Shirokanedai, Minato-ku, Tokyo 108-8639 (Japan); Watanabe, Yasushi [Department of Radiological Technology, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 (Japan); Imamura, Hiroshi [Department of Hepatobiliary-Pancreatic Surgery, Juntendo University School of Medicine, 3-1-3 Hongo, Bunkyo-ku, Tokyo 113-8431 (Japan); Akahane, Masaaki; Yoshioka, Naoki [Department of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 (Japan); Kokudo, Norihiro [Hepato-Biliary-Pancreatic Surgery Division, Department of Surgery, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 (Japan); Ohtomo, Kuni [Department of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 (Japan)

    2011-02-15

    Objective: To quantitatively evaluate the signal intensity of the biliary tract in gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance (MR) imaging and to investigate the effect of liver function on the signal intensity of the biliary tract. Materials and methods: A total of 32 patients with and without chronic liver disease (normal liver group, n = 15; chronic liver disease group, n = 17) were included in this study. All patients were prospectively enrolled for evaluation of known or suspected focal liver lesions. In the chronic liver disease group, the etiologies were chronic hepatitis C virus infection (n = 12) and chronic hepatitis B virus infection (n = 5). The median Child-Pugh score was 5 (range, 5-7). Each patient received the standard dose of Gd-EOB-DTPA (0.025 mmol/kg of body weight). Post-contrast T1-weighted MR images were obtained at 5, 10, 15, 20, 25, and 30 min after administration of Gd-EOB-DTPA. Maximum signal intensities (SIs) of the right and left hepatic ducts, common hepatic duct, and common bile duct were measured. Relative signal intensity was calculated as follows: relative SI = maximum SI{sub bileduct}/mean SI{sub muscle}. Serum albumin level, serum total bilirubin level, prothrombin time, indocyanine green retention rate at 15 min (ICG-R15), and estimated glomerular filtration rate were entered into regression analysis. Results: The signal intensity of the bile duct reached a peak 30 min after administration of Gd-EOB-DTPA. The mean relative signal intensity of the right and left hepatic ducts at the peak time point was not significantly different between the two groups, while increase in signal intensity was delayed in the chronic liver disease group. The mean relative signal intensity of the common hepatic duct and that of the common bile duct at the peak time point were significantly different between the two groups (Wilcoxon rank-sum test, P = 0.03, respectively). Stepwise regression

  11. MR imaging of the biliary tract with Gd-EOB-DTPA: Effect of liver function on signal intensity

    International Nuclear Information System (INIS)

    Takao, Hidemasa; Akai, Hiroyuki; Tajima, Taku; Kiryu, Shigeru; Watanabe, Yasushi; Imamura, Hiroshi; Akahane, Masaaki; Yoshioka, Naoki; Kokudo, Norihiro; Ohtomo, Kuni

    2011-01-01

    Objective: To quantitatively evaluate the signal intensity of the biliary tract in gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance (MR) imaging and to investigate the effect of liver function on the signal intensity of the biliary tract. Materials and methods: A total of 32 patients with and without chronic liver disease (normal liver group, n = 15; chronic liver disease group, n = 17) were included in this study. All patients were prospectively enrolled for evaluation of known or suspected focal liver lesions. In the chronic liver disease group, the etiologies were chronic hepatitis C virus infection (n = 12) and chronic hepatitis B virus infection (n = 5). The median Child-Pugh score was 5 (range, 5-7). Each patient received the standard dose of Gd-EOB-DTPA (0.025 mmol/kg of body weight). Post-contrast T1-weighted MR images were obtained at 5, 10, 15, 20, 25, and 30 min after administration of Gd-EOB-DTPA. Maximum signal intensities (SIs) of the right and left hepatic ducts, common hepatic duct, and common bile duct were measured. Relative signal intensity was calculated as follows: relative SI = maximum SI bileduct /mean SI muscle . Serum albumin level, serum total bilirubin level, prothrombin time, indocyanine green retention rate at 15 min (ICG-R15), and estimated glomerular filtration rate were entered into regression analysis. Results: The signal intensity of the bile duct reached a peak 30 min after administration of Gd-EOB-DTPA. The mean relative signal intensity of the right and left hepatic ducts at the peak time point was not significantly different between the two groups, while increase in signal intensity was delayed in the chronic liver disease group. The mean relative signal intensity of the common hepatic duct and that of the common bile duct at the peak time point were significantly different between the two groups (Wilcoxon rank-sum test, P = 0.03, respectively). Stepwise regression analysis

  12. Clinical significance of the globus pallidus signal intensity ratio in patients with liver cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Iwasa, Motoh; Kawamura, Noriko; Hiranuma, Kiyohiko [Kuwana Municipal Hospital, Mie (Japan)] [and others

    1996-11-01

    The object of this study was to evaluate the clinical value of the globus pallidus signal intensity ratio for the subclinical detection of hepatic encephalopathy. This study comprised 25 patients with liver cirrhosis without overt hepatic encephalopathy. There was a high frequency (56%) of patients exhibiting increased signal in the globus pallidus. The pallidal signal was related to the severity of the liver disease. The auditory brain stem reaction was not correlated with the pallidal intensity and laboratory parameters. During the follow-up study, 3 out of 5 patients presenting overt hepatic encephalopathy showed strong pallidal signals. The results of this investigation suggest that abnormal globus pallidus signal may constitute a useful method for the subclinical detection of hepatic encepalopathy. (author)

  13. Clinical significance of the globus pallidus signal intensity ratio in patients with liver cirrhosis

    International Nuclear Information System (INIS)

    Iwasa, Motoh; Kawamura, Noriko; Hiranuma, Kiyohiko

    1996-01-01

    The object of this study was to evaluate the clinical value of the globus pallidus signal intensity ratio for the subclinical detection of hepatic encephalopathy. This study comprised 25 patients with liver cirrhosis without overt hepatic encephalopathy. There was a high frequency (56%) of patients exhibiting increased signal in the globus pallidus. The pallidal signal was related to the severity of the liver disease. The auditory brain stem reaction was not correlated with the pallidal intensity and laboratory parameters. During the follow-up study, 3 out of 5 patients presenting overt hepatic encephalopathy showed strong pallidal signals. The results of this investigation suggest that abnormal globus pallidus signal may constitute a useful method for the subclinical detection of hepatic encepalopathy. (author)

  14. Pump-to-Signal Intensity Modulation Transfer in Saturated- Gain Fiber Optical Parametric Amplifiers

    DEFF Research Database (Denmark)

    Lali-Dastjerdi, Zohreh; Lund-Hansen, Toke; Rottwitt, Karsten

    2011-01-01

    The pump-to-signal intensity modulation transfer in saturated degenerate FOPAs is numerically investigated over the whole gain bandwidth. The intensity modulation transfer decreases and the OSNR improves when the amplifier operates in the saturation regime....

  15. Higher exercise intensity delays postexercise recovery of impedance-derived cardiac sympathetic activity.

    Science.gov (United States)

    Michael, Scott; Jay, Ollie; Graham, Kenneth S; Davis, Glen M

    2017-08-01

    Systolic time intervals (STIs) provide noninvasive insights into cardiac sympathetic neural activity (cSNA). As the effect of exercise intensity on postexercise STI recovery is unclear, this study investigated the STI recovery profile after different exercise intensities. Eleven healthy males cycled for 8 min at 3 separate intensities: LOW (40%-45%), MOD (75%-80%), and HIGH (90%-95%) of heart-rate (HR) reserve. Bio-impedance cardiography was used to assess STIs - primarily pre-ejection period (PEP; inversely correlated with cSNA), as well as left ventricular ejection time (LVET) and PEP:LVET - during 10 min seated recovery immediately postexercise. Heart-rate variability (HRV), i.e., natural-logarithm of root mean square of successive differences (Ln-RMSSD), was calculated as an index of cardiac parasympathetic neural activity (cPNA). Higher preceding exercise intensity elicited a slower recovery of HR and Ln-RMSSD (p return to baseline by 10 min following any intensity (p ≤ 0.009). Recovery of STIs was also slower following higher intensity exercise (p ≤ 0.002). By 30 s postexercise, higher preceding intensity resulted in a lower PEP (98 ± 14 ms, 75 ± 6 ms, 66 ± 5 ms for LOW, MOD, and HIGH, respectively, p fashion. While exercise intensity must be considered, acute recovery may be a valuable period during which to concurrently monitor these noninvasive indices, to identify potentially abnormal cardiac autonomic responses.

  16. Bilateral Pulvinar Signal Intensity Decrease on T2-Weighted Images in Patients with Aspartylglucosaminuria

    International Nuclear Information System (INIS)

    Autti, T.; Loennqvist, T.; Joensuu, R.

    2008-01-01

    Background: Aspartylglucosaminuria (AGU) is an autosomal recessive lysosomal disease caused by deficiency of aspartylglucosaminidase. A thalamic T2 signal intensity decrease is associated with lysosomal diseases. Purpose: To investigate thalamic signal intensity in AGU by performing a retrospective review of brain magnetic resonance (MR) imaging studies of AGU patients. Material and Methods: A total of 25 MR examinations were available for 11 patients aged between 3 and 32 years (four patients underwent bone marrow transplantation). Of these, 13 examinations were performed after bone marrow transplantation. Five patients had from two to six examinations, and six patients had one examination each. In every patient, the diagnosis of AGU was confirmed by blood and urine tests. Eighteen examinations were performed with a 1.0T imager including dual spin-echo T2 and proton density (PD) axial and coronal images, and 10 examinations also included T1-weighted images. Seven examinations were performed with a 1.5T imager including turbo spin-echo axial and coronal T2-weighted images and axial fluid-attenuated inversion recovery (FLAIR) images; three examinations included T1-weighted three-dimensional magnetization-prepared rapid acquisition gradient-echo (3D MPRAGE) images. The signal intensity of the thalamus and pulvinar in every sequence was compared to that of the putamina. Results: In AGU, thalamic alterations were first detectable on T2-weighted images (25 examinations in 11 patients) from the age of 3 years 6 months, showing decreased signal intensity in 21 of 24 examinations. T1-weighted images (13 examinations) showed slightly increased thalamic signal intensity in five out of seven examinations from the age of 7 years, and PD images (19 examinations) showed decreased signal intensity from the age of 16 years (three examinations). The pulvinar showed decreased signal intensity on spin-echo T2-weighted images for 14 of 18 examinations or on FLAIR sequences for seven

  17. Signal intensity at unenhanced T1-weighted magnetic resonance in the globus pallidus and dentate nucleus after serial administrations of a macrocyclic gadolinium-based contrast agent in children

    Energy Technology Data Exchange (ETDEWEB)

    Rossi Espagnet, Maria Camilla; Bernardi, Bruno; Figa-Talamanca, Lorenzo [Ospedale Pediatrico Bambino Gesu, IRCCS, Neuroradiology Unit, Imaging Department, Rome (Italy); Pasquini, Luca [Ospedale Pediatrico Bambino Gesu, IRCCS, Neuroradiology Unit, Imaging Department, Rome (Italy); University Sapienza, Neuroradiology Unit, Azienda Ospedaliera Sant' Andrea, Rome (Italy); Toma, Paolo [Ospedale Pediatrico Bambino Gesu, IRCCS, Department of Imaging, Rome (Italy); Napolitano, Antonio [Ospedale Pediatrico Bambino Gesu, IRCCS, Enterprise Risk Management, Medical Physics Department, Rome (Italy)

    2017-09-15

    Few studies have been conducted on the relations between T1-weighted signal intensity changes in the pediatric brain following gadolinium-based contrast agent (GBCA) exposure. The purpose of this study is to investigate the effect of multiple administrations of a macrocyclic GBCA on signal intensity in the globus pallidus and dentate nucleus of the pediatric brain on unenhanced T1-weighted MR images. This retrospective study included 50 patients, mean age: 8 years (standard deviation: 4.8 years), with normal renal function exposed to ≥6 administrations of the same macrocyclic GBCA (gadoterate meglumine) and a control group of 59 age-matched GBCA-naive patients. The globus pallidus-to-thalamus signal intensity ratio and dentate nucleus-to-pons signal intensity ratio were calculated from unenhanced T1-weighted images for both patients and controls. A mixed linear model was used to evaluate the effects on signal intensity ratios of the number of GBCA administrations, the time interval between administrations, age, radiotherapy and chemotherapy. T-test analyses were performed to compare signal intensity ratio differences between successive administrations and baseline MR signal intensity ratios in patients compared to controls. P-values were considered significant if <0.05. A significant effect of the number of GBCA administrations on relative signal intensities globus pallidus-to-thalamus (F[8]=3.09; P=0.002) and dentate nucleus-to-pons (F[8]=2.36; P=0.021) was found. The relative signal intensities were higher at last MR examination than at baseline (P<0.001). Quantitative analysis evaluation of globus pallidus:thalamus and dentate nucleus:pons of the pediatric brain demonstrated an increase after serial administrations of macrocyclic GBCA. Further research is necessary to fully understand GBCA pharmacokinetic in children. (orig.)

  18. Catalogue of European earthquakes with intensities higher than 4

    International Nuclear Information System (INIS)

    Van Gils, J.M.; Leydecker, G.

    1991-01-01

    The catalogue of European earthquakes with intensities higher than 4 contains some 20 000 seismic events that happened in member countries of the European Communities, Switzerland and Austria. It was prepared on the basis of already existing national catalogues and includes historical data as well as present-day data. All historical data are harmonized as far as possible to the same intensity scale (MSK-scale) to make them suitable for computerization. Present-day data include instrumental and macroseismic data. Instrumental data are expressed in terms of magnitude (Richter scale) while macroseismic data are given in intensities. Compilation of seismic data can provide a basis for statistically supported studies of site selection procedures and the qualitative assessment of seismic risks. Three groups of seismic maps illustrate the content of the catalogue for different time periods and different intensities

  19. Mis-segmentation in voxel-based morphometry due to a signal intensity change in the putamen.

    Science.gov (United States)

    Goto, Masami; Abe, Osamu; Miyati, Tosiaki; Aoki, Shigeki; Gomi, Tsutomu; Takeda, Tohoru

    2017-12-01

    The aims of this study were to demonstrate an association between changes in the signal intensity of the putamen on three-dimensional T1-weighted magnetic resonance images (3D-T1WI) and mis-segmentation, using the voxel-based morphometry (VBM) 8 toolbox. The sagittal 3D-T1WIs of 22 healthy volunteers were obtained for VBM analysis using the 1.5-T MR scanner. We prepared five levels of 3D-T1WI signal intensity (baseline, same level, background level, low level, and high level) in regions of interest containing the putamen. Groups of smoothed, spatially normalized tissue images were compared to the baseline group using a paired t test. The baseline was compared to the other four levels. In all comparisons, significant volume changes were observed around and outside the area that included the signal intensity change. The present study demonstrated an association between a change in the signal intensity of the putamen on 3D-T1WI and changed volume in segmented tissue images.

  20. Effect of the luminol signal enhancer on the chemiluminescence intensity and kinetics

    International Nuclear Information System (INIS)

    Liang Yanli; Yu Fei; Yu Songcheng; Wu Yongjun; Zhang Hongquan; Qu Lingbo

    2012-01-01

    The novel p-phenol derivatives, 4-(1-imidazolyl)-phenol, 4-hydroxybiphenyl, 4-hydroxy-4′-iodobiphenyl were employed as highly potent signal enhancers of luminol-hydrogen peroxide (H 2 O 2 )-horseradish peroxidase (HRP) chemiluminescence (CL) system. The CL reaction conditions were optimized, and the enhancement characteristics of these enhancers were compared with each other. The employment of these molecules greatly affected important assay parameters. Practically, the use of a novel enhancer, even a slightly change of the structure (or concentration) of 4-substituted phenol derivative, could affect assay properties quite dramatically. Furthermore, the use of different enhancers in the luminol–H 2 O 2 –HRP system can affect not only the intensity of the CL signal, which is well known, but also its kinetics. The experiment data indicated that the stronger intensity was combined with a more rapid decrease of the CL signal. - Highlights: ► 4-IMP, 4-BIP and HIOP take on different signal enhancement and light kinetics. ► The employment of 4-BIP resulted in a significant improvement of the detection limit. ► The magnitude of the signal enhancement was about 2.5-fold in the same system.

  1. Magnetic resonance imaging signal intensity of temporomandibular joint disk and posterior attachment in patients with internal derangement

    International Nuclear Information System (INIS)

    Jeong, Yeon Hwa; Cho, Bong Hae

    2001-01-01

    To analyze the possible association between magnetic resonance imaging signal intensity of temporomandibular joint disk and posterior attachment, and the type and extent of disk displacement, disk donfiguration, effusion and clinical signs in patients with internal derangement. Magnetic resonance images of the 132 temporomandibular joints of 66 patients with temporomandibular joint displacement were analyzed. The clinical findings were obtained by retrospective review of the patients' records. The type and extent of disk displacement, disk configuration and effusion were evaluated on the proton density MR images. The signal intensity from the anterior band, posterior band and posterior attachment were measured on MR images. The associations between the type and extent of disk displacement, disk configuration, effusion and clinical signs and the MR signal intensity of disk and posterior attachment were statistically analyzed by student's t-test. Of 132 joints, 87 (65.9%) showed anterior disk displacement with reduction (ADR) and 45 (34.1%) showed anterior disk displacement without reduction (ADnR). This signals from posterior attachments were lower in joints with ADnR than those of ADR (p<0.05). The results showed statistically significant (p<0.05) association between the type and extent of disk displacement and disk configuration, and decreased signal intensity of posterior attachment. There were no statistical associations between pain, noise and limited mouth opening, and signal intensity of disk and posterior attachment. The average signal from posterior attachment was lower in joints with ADnR than that of ADR. The type and extent of disk displacement and disk configuration appeared to be correlated with the signal intensity from posterior attachment

  2. Arterial spin-labeling assessment of normalized vascular intratumoral signal intensity as a predictor of histologic grade of astrocytic neoplasms.

    Science.gov (United States)

    Furtner, J; Schöpf, V; Schewzow, K; Kasprian, G; Weber, M; Woitek, R; Asenbaum, U; Preusser, M; Marosi, C; Hainfellner, J A; Widhalm, G; Wolfsberger, S; Prayer, D

    2014-03-01

    Pulsed arterial spin-labeling is a noninvasive MR imaging perfusion method performed with the use of water in the arterial blood as an endogenous contrast agent. The purpose of this study was to determine the inversion time with the largest difference in normalized intratumoral signal intensity between high-grade and low-grade astrocytomas. Thirty-three patients with gliomas, histologically classified as low-grade (n = 7) or high-grade astrocytomas (n = 26) according to the World Health Organization brain tumor classification, were included. A 3T MR scanner was used to perform pulsed arterial spin-labeling measurements at 8 different inversion times (370 ms, 614 ms, 864 ms, 1114 ms, 1364 ms, 1614 ms, 1864 ms, and 2114 ms). Normalized intratumoral signal intensity was calculated, which was defined by the signal intensity ratio of the tumor and the contralateral normal brain tissue for all fixed inversion times. A 3-way mixed ANOVA was used to reveal potential differences in the normalized vascular intratumoral signal intensity between high-grade and low-grade astrocytomas. The difference in normalized vascular intratumoral signal intensity between high-grade and low-grade astrocytomas obtained the most statistically significant results at 370 ms (P = .003, other P values ranged from .012-.955). The inversion time by which to differentiate high-grade and low-grade astrocytomas by use of normalized vascular intratumoral signal intensity was 370 ms in our study. The normalized vascular intratumoral signal intensity values at this inversion time mainly reflect the labeled intra-arterial blood bolus and therefore could be referred to as normalized vascular intratumoral signal intensity. Our data indicate that the use of normalized vascular intratumoral signal intensity values allows differentiation between low-grade and high-grade astrocytomas and thus may serve as a new, noninvasive marker for astrocytoma grading.

  3. Analysis of high signal intensities of nontumorous conditions of corpus callosum on magnetic resonance T2-weighted images

    International Nuclear Information System (INIS)

    Kang, Moo Song; Kim, Chul Min; Chung, Chun Phil

    1995-01-01

    To evaluate high signal intensity of nontumorous conditions of corpus callosum on T2-weighted MR images. Forty nine patients with nontumorous high signal intensities involving corpus callosum on sagittal T2-weighted image were retrospectively analyzed. Nontumorous condition of corpus callosum were diffuse axonal injury (DAI, 19 cases), cerebral infarctions (16 cases), multiple sclerosis (MS, 5 cases), Wilson's disease (2 cases) and hydrocephalus (7 cases) that were diagnosed by clinical and MR findings. Numbers, configuration, involved thickness and sites of high signal intensities of corpus callosum were analyzed. DAI and infarctions showed either single or multiple lesions. MS and hydrocephalus showed multiple lesions, but Wilson's diseases showed single lesion. In DAI, infarctions and MS the lesions involved any part of corpus callosum, splenium in Wilson's disease, and all parts of corpus callosum in hydrocephalus. Wilson's disease showed only partial thickness involvement, and others involved partial or full thickness of corpus callosum. Configuration of high signal intensity was linear in most cases of hydrocephalus, and oval in Wilson's disease, and oval and confluent in MS, and variable in DAI and infarctions. High signal intensities of nontumorous conditions of corpus callosum revealed variable findings, and therefore, analysis of nontumorous high signal intensities of corpus callosum is not made by only MR findings but by conjuction with clinical aspects

  4. Muscle MRI STIR signal intensity and atrophy are correlated to focal lower limb neuropathy severity.

    Science.gov (United States)

    Deroide, N; Bousson, V; Mambre, L; Vicaut, E; Laredo, J D; Kubis, Nathalie

    2015-03-01

    The objective is to determine if muscle MRI is useful for assessing neuropathy severity. Clinical, MRI and electromyography (EMG) examinations were performed in 17 patients with focal lower limb neuropathies. MRI Short Tau Inversion Recovery (STIR) signal intensity, amyotrophy, and muscle fatty infiltration measured after T1-weighted image acquisition, EMG spontaneous activity (SA), and maximal voluntary contraction (MVC) were graded using semiquantitative scores and quantitative scores for STIR signal intensity and were correlated to the Medical Research Council (MRC) score for testing muscle strength. Within this population, subgroups were selected according to severity (mild versus severe), duration (subacute versus chronic), and topography (distal versus proximal) of the neuropathy. EMG SA and MVC MRI amyotrophy and quantitative scoring of muscle STIR intensity were correlated with the MRC score. Moreover, MRI amyotrophy was significantly increased in severe, chronic, and proximal neuropathies along with fatty infiltration in chronic lesions. Muscle MRI atrophy and quantitative evaluation of signal intensity were correlated to MRC score in our study. Semiquantitative evaluation of muscle STIR signal was sensitive enough for detection of topography of the nerve lesion but was not suitable to assess severity. Muscle MRI could support EMG in chronic and proximal neuropathy, which showed poor sensitivity in these patients.

  5. Muscle MRI STIR signal intensity and atrophy are correlated to focal lower limb neuropathy severity

    Energy Technology Data Exchange (ETDEWEB)

    Deroide, N.; Mambre, L.; Kubis, Nathalie [Service de Physiologie Clinique-Explorations Fonctionnelles, AP-HP, Hopital Lariboisiere, Paris (France); Universite Paris Diderot, Sorbonne Paris Cite France, Paris (France); Bousson, V.; Laredo, J.D. [Universite Paris Diderot, Sorbonne Paris Cite France, Paris (France); Radiologie Osteo-articulaire, AP-HP, Hopital Lariboisiere, Paris (France); Vicaut, E. [Universite Paris Diderot, Sorbonne Paris Cite France, Paris (France); URC, AP-HP, Hopital Lariboisiere, Paris (France)

    2014-09-26

    The objective is to determine if muscle MRI is useful for assessing neuropathy severity. Clinical, MRI and electromyography (EMG) examinations were performed in 17 patients with focal lower limb neuropathies. MRI Short Tau Inversion Recovery (STIR) signal intensity, amyotrophy, and muscle fatty infiltration measured after T1-weighted image acquisition, EMG spontaneous activity (SA), and maximal voluntary contraction (MVC) were graded using semiquantitative scores and quantitative scores for STIR signal intensity and were correlated to the Medical Research Council (MRC) score for testing muscle strength. Within this population, subgroups were selected according to severity (mild versus severe), duration (subacute versus chronic), and topography (distal versus proximal) of the neuropathy. EMG SA and MVC MRI amyotrophy and quantitative scoring of muscle STIR intensity were correlated with the MRC score. Moreover, MRI amyotrophy was significantly increased in severe, chronic, and proximal neuropathies along with fatty infiltration in chronic lesions. Muscle MRI atrophy and quantitative evaluation of signal intensity were correlated to MRC score in our study. Semiquantitative evaluation of muscle STIR signal was sensitive enough for detection of topography of the nerve lesion but was not suitable to assess severity. Muscle MRI could support EMG in chronic and proximal neuropathy, which showed poor sensitivity in these patients. (orig.)

  6. Numerical modelling of the pump-to-signal relative intensity noise ...

    Indian Academy of Sciences (India)

    An accurate numerical model to investigate the pump-to-signal relative intensity noise (RIN) transfer in two-pump fibre optical parametric amplifiers (2-P FOPAs) for low modulation frequencies is presented. Compared to other models in the field, this model takes into account the fibre loss, pump depletion as well as the gain ...

  7. Signal quality enhancement using higher order wavelets for ultrasonic TOFD signals from austenitic stainless steel welds.

    Science.gov (United States)

    Praveen, Angam; Vijayarekha, K; Abraham, Saju T; Venkatraman, B

    2013-09-01

    Time of flight diffraction (TOFD) technique is a well-developed ultrasonic non-destructive testing (NDT) method and has been applied successfully for accurate sizing of defects in metallic materials. This technique was developed in early 1970s as a means for accurate sizing and positioning of cracks in nuclear components became very popular in the late 1990s and is today being widely used in various industries for weld inspection. One of the main advantages of TOFD is that, apart from fast technique, it provides higher probability of detection for linear defects. Since TOFD is based on diffraction of sound waves from the extremities of the defect compared to reflection from planar faces as in pulse echo and phased array, the resultant signal would be quite weak and signal to noise ratio (SNR) low. In many cases the defect signal is submerged in this noise making it difficult for detection, positioning and sizing. Several signal processing methods such as digital filtering, Split Spectrum Processing (SSP), Hilbert Transform and Correlation techniques have been developed in order to suppress unwanted noise and enhance the quality of the defect signal which can thus be used for characterization of defects and the material. Wavelet Transform based thresholding techniques have been applied largely for de-noising of ultrasonic signals. However in this paper, higher order wavelets are used for analyzing the de-noising performance for TOFD signals obtained from Austenitic Stainless Steel welds. It is observed that higher order wavelets give greater SNR improvement compared to the lower order wavelets. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. In vitro study of relationship between signal intensity and gadolinium-DTPA concentration at high magnetic field strength

    International Nuclear Information System (INIS)

    Shahbazi-Gahrouei, D.; Williams, M.; Allen, B.J.

    2001-01-01

    Although gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA) has been used as a contrast material in MRI, it is known that the contrast enhancement effect is not uniform for high concentrations of Gd-DTPA. In order to evaluate the proper pulse sequences for dynamic MRI in aqueous solutions of Gd-DTPA, blood samples and melanoma cells, the signal intensity for several concentrations of Gd-DTPA were measured under inversion recovery T 1 -weighted) at high magnetic field strength (7.0 Tesla). For aqueous solutions of Gd-DTPA, signal intensity correlated linearly with the concentration of Gd-DTPA between 0 mmol/L and 4 mmol/L. Using blood and melanoma cells, signal intensity correlated non-linearly with the concentration of Gd-DTPA between 0 mmol/L and 1.5 mmol/L. For concentrations of more than 4 mmol/L in aqueous solutions of Gd-DTPA, 1 mmol/L in blood and 1.5 mmol/L in melanoma, signal intensity decreased with increased Gd-DTPA concentration. Copyright (2001) Blackwell Science Pty Ltd

  9. Magnetic resonance imaging of the supraspinatus tendon: The significance of signal intensity alterations at the 'critical zone'

    International Nuclear Information System (INIS)

    Jones, A.O.

    1998-01-01

    A pictorial essay of normal and abnormal appearances of the supraspinatus tendon is presented. An increased signal intensity within the supraspinatus tendon on short TE sequences is not necessarily abnormal. Increased signal seen within the tendon on modern magnetic resonance imaging (MRI) units is often due to a phenomenon known as the 'magic angle' effect. Only when supraspinatus tendon signal intensity is greater than that of muscle on long TE (T2) sequences should it be considered to be abnormal. The physical basis for the magic angle effect is outlined and a pictorial essay demonstrating the practical implications of this effect is presented. A comparison is made to signal intensity changes seen with partial and complete tears of the supraspinatus tendon. Correlation is made with important morphologic features of partial or complete tears. Copyright (1998) Blackwell Science Pty Ltd

  10. Continuous and high-intensity interval training: which promotes higher pleasure?

    Directory of Open Access Journals (Sweden)

    Bruno R R Oliveira

    Full Text Available OBJECTIVES: To compare the psychological responses to continuous (CT and high-intensity interval training (HIT sessions. METHODS: Fifteen men attended one CT session and one HIT session. During the first visit, the maximum heart rate, VO2Peak and respiratory compensation point (RCP were determined through a maximal cardiopulmonary exercise test. The HIT stimulus intensity corresponded to 100% of VO2Peak, and the average intensity of both sessions was maintained at 15% below the RCP. The order of the sessions was randomized. Psychological and physiological variables were recorded before, during and after each session. RESULTS: There were no significant differences between the average percentages of VO2 during the two exercise sessions (HIT: 73.3% vs. CT: 71.8%; p = 0.779. Lower responses on the feeling scale (p≤0.01 and higher responses on the felt arousal scale (p≤0.001 and the rating of perceived exertion were obtained during the HIT session. Despite the more negative feeling scale responses observed during HIT and a greater feeling of fatigue (measured by Profile of Mood States afterwards (p<0.01, the physical activity enjoyment scale was not significantly different between the two conditions (p = 0.779. CONCLUSION: Despite the same average intensity for both conditions, similar psychological responses under HIT and CT conditions were not observed, suggesting that the higher dependence on anaerobic metabolism during HIT negatively influenced the feeling scale responses.

  11. Increased signal intensities in the dentate nucleus and globus pallidus on unenhanced T1-weighted images: evidence in children undergoing multiple gadolinium MRI exams

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Houchun H.; Pokorney, Amber; Towbin, Richard B.; Miller, Jeffrey H. [Phoenix Children' s Hospital, Department of Medical Imaging and Radiology, Phoenix, AZ (United States)

    2016-10-15

    Recent reports have suggested residual gadolinium deposition in the brain in subjects undergoing multiple contrast-enhanced MRI exams. These findings have raised some concerns regarding gadolinium-based contrast agent (GBCA) usage and retention in brain tissues. To summarize findings of hyperintense brain structures on precontrast T1-weighted images in 21 children undergoing multiple GBCA MRI exams. This retrospective study involved 21 patients, each of whom received multiple MRI examinations (range: 5-37 exams) with GBCA over the course of their medical treatment (duration from first to most recent exam: 1.2-12.9 years). The patients were between 0.9 and 14.4 years of age at the time of their first GBCA exam. Regions of interest were drawn in the dentate nucleus and the globus pallidus on 2-D fast spin echo images acquired at 1.5 T. The signal intensities of these two structures were normalized by that of the corpus callosum genu. Signal intensity ratios from these patients were compared to control patients of similar ages who have never received GBCA. Signal intensity ratios increased between the first and the most recent MRI exam in all 21 patients receiving GBCA, with an increase of 18.6%±12.7% (range: 0.5% to 47.5%) for the dentate nucleus and 12.4%±7.4% (range: -1.2% to 33.7%) for the globus pallidus (P<0.0001). Signal intensity ratios were also higher in GBCA patients than in controls (P<0.01). The degree of signal intensity enhancement did not correlate with statistical significance to the cumulative number or volume of GBCA administrations each patient received, the patient's age or the elapsed time between the first and most recent GBCA MRI exams. These results in children are consistent with recent findings in adults, suggesting possible gadolinium deposition in the brain. (orig.)

  12. Lumber intervertebral disk; Correlation with the signal intensity of magnetic resonance imaging and the histological changes

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Ryusei; Takahashi, Sadao; Ando, Tadashi; Kumano, Kiyoshi; Hiranuma, Kenji; Kanazawa, Yousuke; Konishi, Seiji; Eguchi, Masanobu; Tanioka, Hisaya (KantoRosai Hospital, Kawasaki, Kanagawa (Japan))

    1989-11-01

    We studied to provide precise correlations between the intensity of MRI signals and the degenerative changes of the nucleus pulposes of the L4/5 intervertebral disk herniations. 23 cases with the L4/5 intervertebral disk herniations having surgical treatment were examined using Magnetom H 15 (1.5 tesla) with surface coil. The images were obtained with T2 images (long TR (1000{approx}1600 msec), TE (60{approx}90 msec)). The intensity was measured using FUJI densitometer FD 101 at the lumber vertebral body and the intervertebral disk. We calculated the L4/5 intervertebral disk degeneration ratio (determined by comparing the modified L4/5 MR signal intensity with the modified L2/3 MR signal itensity). Histological changes were examined in the cellular components of the nucleus pulposus (such as the number of the nucleus cells, nucleus cell nesting and HE stainability of the nucleus cell) and the matrics substance (such as fibrillation, hyaline degeneration and granular degeneration). Histochemical studies were performed using Scott's Method (AB-0.4 M MgCl{sub 2} Alcinophilia, AB-09 M, MgCl{sub 2} Alcinophilia) to investigate glycosaminoglycans of the nucleus pulposus. We compared the histological and histochemical changes with the MR L4/5 intervetebral disk degeneration ratio. The decreasing MRI signal intensity of the nucleous pulposus was (1) corresponded to the pathological changes such as the increasing number of the cell nesting, fibrillation and hyaline degeneration of the nucleus polposus. (2) corresponded to the decrease in the total glycosaminoglycans of the nucleus pulposus. (3) corresponded to the early stage of degeneration of the nucleus polposus, but in aging when all levels of intervertebral disk degeneration appeared, we could not know the degree of the disk degeneration from the signal intensity of MRI. (J.P.N.).

  13. Increased signal intensity of the cochlea on pre- and post-contrast enhanced 3D-FLAIR in patients with vestibular schwannoma

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Masahiro; Naganawa, Shinji; Kawai, Hisashi; Nihashi, Takashi [Nagoya University, Department of Radiology, Graduate School of Medicine, Nagoya (Japan); Fukatsu, Hiroshi [Aichi Medical University Hospital, Department of Medical Informatics, Nagakute (Japan); Nakashima, Tsutomu [Nagoya University, Department of Otorhinolaryngology, Graduate School of Medicine, Nagoya (Japan)

    2009-12-15

    In the vestibular schwannoma patients, the pathophysiologic mechanism of inner ear involvement is still unclear. We investigated the status of the cochleae in patients with vestibular schwannoma by evaluating the signal intensity of cochlear fluid on pre- and post-contrast enhanced thin section three-dimensional fluid-attenuated inversion recovery (3D-FLAIR). Twenty-eight patients were retrospectively analyzed. Post-contrast images were obtained in 18 patients, and 20 patients had the records of their pure-tone audiometry. Regions of interest of both cochleae (C) and of the medulla oblongata (M) were determined on 3D-FLAIR images by referring to 3D heavily T2-weighted images on a workstation. The signal intensity ratio between C and M on the 3D-FLAIR images (CM ratio) was then evaluated. In addition, correlation between the CM ratio and the hearing level was also evaluated. The CM ratio of the affected side was significantly higher than that of the unaffected side (p < 0.001). In the affected side, post-contrast signal elevation was observed (p < 0.005). In 13 patients (26 cochleae) who underwent both gadolinium injection and the pure-tone audiometry, the post-contrast CM ratio correlated with hearing level (p < 0.05). The results of the present study suggest that alteration of cochlear fluid composition and increased permeability of the blood-labyrinthine barrier exist in the affected side in patients with vestibular schwannoma. Furthermore, although weak, positive correlation between post-contrast cochlear signal intensity on 3D-FLAIR and hearing level warrants further study to clarify the relationship between 3D-FLAIR findings and prognosis of hearing preservation surgery. (orig.)

  14. Increased signal intensity of the cochlea on pre- and post-contrast enhanced 3D-FLAIR in patients with vestibular schwannoma

    International Nuclear Information System (INIS)

    Yamazaki, Masahiro; Naganawa, Shinji; Kawai, Hisashi; Nihashi, Takashi; Fukatsu, Hiroshi; Nakashima, Tsutomu

    2009-01-01

    In the vestibular schwannoma patients, the pathophysiologic mechanism of inner ear involvement is still unclear. We investigated the status of the cochleae in patients with vestibular schwannoma by evaluating the signal intensity of cochlear fluid on pre- and post-contrast enhanced thin section three-dimensional fluid-attenuated inversion recovery (3D-FLAIR). Twenty-eight patients were retrospectively analyzed. Post-contrast images were obtained in 18 patients, and 20 patients had the records of their pure-tone audiometry. Regions of interest of both cochleae (C) and of the medulla oblongata (M) were determined on 3D-FLAIR images by referring to 3D heavily T2-weighted images on a workstation. The signal intensity ratio between C and M on the 3D-FLAIR images (CM ratio) was then evaluated. In addition, correlation between the CM ratio and the hearing level was also evaluated. The CM ratio of the affected side was significantly higher than that of the unaffected side (p < 0.001). In the affected side, post-contrast signal elevation was observed (p < 0.005). In 13 patients (26 cochleae) who underwent both gadolinium injection and the pure-tone audiometry, the post-contrast CM ratio correlated with hearing level (p < 0.05). The results of the present study suggest that alteration of cochlear fluid composition and increased permeability of the blood-labyrinthine barrier exist in the affected side in patients with vestibular schwannoma. Furthermore, although weak, positive correlation between post-contrast cochlear signal intensity on 3D-FLAIR and hearing level warrants further study to clarify the relationship between 3D-FLAIR findings and prognosis of hearing preservation surgery. (orig.)

  15. High-Intensity Interval Training Elicits Higher Enjoyment than Moderate Intensity Continuous Exercise.

    Directory of Open Access Journals (Sweden)

    Jacob S Thum

    Full Text Available Exercise adherence is affected by factors including perceptions of enjoyment, time availability, and intrinsic motivation. Approximately 50% of individuals withdraw from an exercise program within the first 6 mo of initiation, citing lack of time as a main influence. Time efficient exercise such as high intensity interval training (HIIT may provide an alternative to moderate intensity continuous exercise (MICT to elicit substantial health benefits. This study examined differences in enjoyment, affect, and perceived exertion between MICT and HIIT. Twelve recreationally active men and women (age = 29.5 ± 10.7 yr, VO2max = 41.4 ± 4.1 mL/kg/min, BMI = 23.1 ± 2.1 kg/m2 initially performed a VO2max test on a cycle ergometer to determine appropriate workloads for subsequent exercise bouts. Each subject returned for two additional exercise trials, performing either HIIT (eight 1 min bouts of cycling at 85% maximal workload (Wmax with 1 min of active recovery between bouts or MICT (20 min of cycling at 45% Wmax in randomized order. During exercise, rating of perceived exertion (RPE, affect, and blood lactate concentration (BLa were measured. Additionally, the Physical Activity Enjoyment Scale (PACES was completed after exercise. Results showed higher enjoyment (p = 0.013 in response to HIIT (103.8 ± 9.4 versus MICT (84.2 ± 19.1. Eleven of 12 participants (92% preferred HIIT to MICT. However, affect was lower (p<0.05 and HR, RPE, and BLa were higher (p<0.05 in HIIT versus MICT. Although HIIT is more physically demanding than MICT, individuals report greater enjoyment due to its time efficiency and constantly changing stimulus.NCT:02981667.

  16. Higher-Order Blind Signal Feature Separation: An Enabling Technology for Battlefield Awareness

    National Research Council Canada - National Science Library

    Su, Wei; Kosinski, John A

    2006-01-01

    Higher-order transform blind signal feature classification is discussed for separating bar-shaped, circular, squared, circular-squared, and offset-diamonded constellation patterns of digital linear signals...

  17. MR imaging of degenerative lumbar disc disease emphasizing on signal intensity changes in vertebral body

    International Nuclear Information System (INIS)

    Toyoda, Keiko; Ida, Masahiro; Murakami, Yoshitaka; Harada, Junta; Tada, Shimpei

    1992-01-01

    Magnetic resonance imaging was performed in 400 patients with degenerative disc disease. Signal changes and their sites in the vertebral body were classified and referred to narrowing of the intervertebral disc space. MR findings were compared with those of plain roentgenograms of the lumbar spine. Signal changes in the vertebral body were noted in 83 cases (102 vertebral bodies). Low-intensity abnormality on both T1- and T2-weighted images (WI) was the most common finding, and was most frequently seen at the end plate and/or the angle. These changes were correlated with narrowing of the disc space and osteosclerosis on the plain roentgenogram of the lumbar spine. Signal changes occasionally occurred in the inner region of the vertebral body, and these lesions tended to show a high-intensity abnormality on T1-WI. We conclude that signal changes in degenerative disc disease are not specific, but are sometimes difficult to distinguish from the signal changes in other conditions such as spinal tumor or bone marrow disorder. (author)

  18. Assessment of lung development in isolated congenital diaphragmatic hernia using signal intensity ratios on fetal MR imaging

    International Nuclear Information System (INIS)

    Balassy, Csilla; Kasprian, Gregor; Weber, Michael; Herold, Christian; Prayer, Daniela; Brugger, Peter C.; Csapo, Bence

    2010-01-01

    To investigate developmental changes in the apparently unaffected contralateral lung by using signal intensity ratios (SIR) and lung volumes (LV), and to search for correlation with clinical outcome. Twenty-five fetuses (22-37 weeks' gestation) were examined. Lung/liver signal intensity ratios (LLSIR) were assessed on T1-weighted and T2-weighted sequences for both lungs, then together with LV compared with age-matched controls of 91 fetuses by using the U test. Differences in LLSIRs and lung volumes were correlated with neonatal outcomes. LLSIRs in fetuses with congenital diaphragmatic hernia (CDH) were significantly higher in both lungs on T1-weighted images and significantly lower on T2-weighted images, compared with normals (p < 0.05), increasing on T2-weighted imaging and decreasing on T1-weighted imaging during gestation. Total LV were significantly smaller in the CDH group than in controls (p < 0.05). No significant differences in LLSIR of the two lungs were found. Outcomes correlated significantly with total LV, but not with LLSIR. Changes in LLSIR seem to reflect developmental impairment in CDH; however, they provide no additional information in predicting outcome. LV remains the best indicator on fetal MR imaging of neonatal survival in isolated, left-sided CDH. (orig.)

  19. Assessment of lung development in isolated congenital diaphragmatic hernia using signal intensity ratios on fetal MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Balassy, Csilla; Kasprian, Gregor; Weber, Michael; Herold, Christian; Prayer, Daniela [Medical University of Vienna, Department of Radiology, Vienna (Austria); Brugger, Peter C. [Medical University of Vienna, Centre of Anatomy and Cell Biology, Vienna (Austria); Csapo, Bence [Medical University of Vienna, Department of Obstetrics and Gyneocology, Vienna (Austria)

    2010-04-15

    To investigate developmental changes in the apparently unaffected contralateral lung by using signal intensity ratios (SIR) and lung volumes (LV), and to search for correlation with clinical outcome. Twenty-five fetuses (22-37 weeks' gestation) were examined. Lung/liver signal intensity ratios (LLSIR) were assessed on T1-weighted and T2-weighted sequences for both lungs, then together with LV compared with age-matched controls of 91 fetuses by using the U test. Differences in LLSIRs and lung volumes were correlated with neonatal outcomes. LLSIRs in fetuses with congenital diaphragmatic hernia (CDH) were significantly higher in both lungs on T1-weighted images and significantly lower on T2-weighted images, compared with normals (p < 0.05), increasing on T2-weighted imaging and decreasing on T1-weighted imaging during gestation. Total LV were significantly smaller in the CDH group than in controls (p < 0.05). No significant differences in LLSIR of the two lungs were found. Outcomes correlated significantly with total LV, but not with LLSIR. Changes in LLSIR seem to reflect developmental impairment in CDH; however, they provide no additional information in predicting outcome. LV remains the best indicator on fetal MR imaging of neonatal survival in isolated, left-sided CDH. (orig.)

  20. Association between duration of coronary occlusion and high-intensity signal on T1-weighted magnetic resonance imaging among patients with angiographic total occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Kenji; Ehara, Shoichi; Hasegawa, Takao; Sakaguchi, Mikumo; Shimada, Kenei [Osaka City University Graduate School of Medicine, Department of Cardiovascular Medicine, Abeno-ku, Osaka (Japan)

    2017-09-15

    To evaluate the association between duration of the coronary occlusion and high-intensity signal (HIS) on noncontrast T1-weighted imaging using a 1.5-T magnetic resonance imager among patients with angiographic coronary total occlusion. The signal intensity of the coronary target area divided by the signal intensity of the left ventricular muscle near the target area at each site (TMR) was measured. Areas with a TMR >1.0 were defined as HIS. Thirty five lesions from 33 patients were divided into the following three groups: subacute occlusion (up to 3 months; n = 7), short-duration chronic total occlusion (SD-CTO: 3-6 months; n = 9) and long-duration CTO (LD-CTO: ≥6 months; n = 19). All subacute occlusion lesions showed a HIS within the occlusion site. Among patients with CTO, the frequency of a HIS within the occlusion site was significantly higher in SD-CTO than in LD-CTO lesions (p = 0.013). In multivariate analyses, only an occlusion duration of less than 6 months was an independent factor associated with the presence of HIS (odds ratio 7.6, 95% CI 1.1-54.5; p = 0.044). The presence of a HIS in the occlusion site was associated more with SD-CTO than with LD-CTO among patients with CTO. (orig.)

  1. Association between duration of coronary occlusion and high-intensity signal on T1-weighted magnetic resonance imaging among patients with angiographic total occlusion

    International Nuclear Information System (INIS)

    Matsumoto, Kenji; Ehara, Shoichi; Hasegawa, Takao; Sakaguchi, Mikumo; Shimada, Kenei

    2017-01-01

    To evaluate the association between duration of the coronary occlusion and high-intensity signal (HIS) on noncontrast T1-weighted imaging using a 1.5-T magnetic resonance imager among patients with angiographic coronary total occlusion. The signal intensity of the coronary target area divided by the signal intensity of the left ventricular muscle near the target area at each site (TMR) was measured. Areas with a TMR >1.0 were defined as HIS. Thirty five lesions from 33 patients were divided into the following three groups: subacute occlusion (up to 3 months; n = 7), short-duration chronic total occlusion (SD-CTO: 3-6 months; n = 9) and long-duration CTO (LD-CTO: ≥6 months; n = 19). All subacute occlusion lesions showed a HIS within the occlusion site. Among patients with CTO, the frequency of a HIS within the occlusion site was significantly higher in SD-CTO than in LD-CTO lesions (p = 0.013). In multivariate analyses, only an occlusion duration of less than 6 months was an independent factor associated with the presence of HIS (odds ratio 7.6, 95% CI 1.1-54.5; p = 0.044). The presence of a HIS in the occlusion site was associated more with SD-CTO than with LD-CTO among patients with CTO. (orig.)

  2. A paradoxical signal intensity increase in fatty livers using opposed-phase gradient echo imaging with fat-suppression pulses

    International Nuclear Information System (INIS)

    Mulkern, Robert V.; Voss, Stephan; Loeb Salsberg, Sandra; Krauel, Marta Ramon; Ludwig, David S.

    2008-01-01

    With the increase in obese and overweight children, nonalcoholic fatty liver disease has become more prevalent in the pediatric population. Appreciating subtleties of magnetic resonance (MR) signal intensity behavior from fatty livers under different imaging conditions thus becomes important to pediatric radiologists. We report an initially confusing signal behavior - increased signal from fatty livers when fat-suppression pulses are applied in an opposed-phase gradient echo imaging sequence - and seek to explain the physical mechanisms for this paradoxical signal intensity behavior. Abdominal MR imaging at 3 T with a 3-D volumetric interpolated breath-hold (VIBE) sequence in the opposed-phase condition (TR/TE 3.3/1.3 ms) was performed in five obese boys (14±2 years of age, body mass index >95th percentile for age and sex) with spectroscopically confirmed fatty livers. Two VIBE acquisitions were performed, one with and one without the use of chemical shift selective (CHESS) pulse fat suppression. The ratios of fat-suppressed over non-fat-suppressed signal intensities were assessed in regions-of-interest (ROIs) in five tissues: subcutaneous fat, liver, vertebral marrow, muscle and spleen. The boys had spectroscopically estimated hepatic fat levels between 17% and 48%. CHESS pulse fat suppression decreased subcutaneous fat signals dramatically, by more than 85% within regions of optimal fat suppression. Fatty liver signals, in contrast, were elevated by an average of 87% with CHESS pulse fat suppression. Vertebral marrow signal was also significantly elevated with CHESS pulse fat suppression, while spleen and muscle signals demonstrated only small signal increases on the order of 10%. We demonstrated that CHESS pulse fat suppression actually increases the signal intensity from fatty livers in opposed-phase gradient echo imaging conditions. The increase can be attributed to suppression of one partner of the opposed-phase pair that normally contributes to the

  3. A paradoxical signal intensity increase in fatty livers using opposed-phase gradient echo imaging with fat-suppression pulses

    Energy Technology Data Exchange (ETDEWEB)

    Mulkern, Robert V.; Voss, Stephan [Harvard Medical School, Department of Radiology, Children' s Hospital Boston, Boston, MA (United States); Loeb Salsberg, Sandra; Krauel, Marta Ramon; Ludwig, David S. [Harvard Medical School, Department of Medicine, Children' s Hospital Boston, Boston, MA (United States)

    2008-10-15

    With the increase in obese and overweight children, nonalcoholic fatty liver disease has become more prevalent in the pediatric population. Appreciating subtleties of magnetic resonance (MR) signal intensity behavior from fatty livers under different imaging conditions thus becomes important to pediatric radiologists. We report an initially confusing signal behavior - increased signal from fatty livers when fat-suppression pulses are applied in an opposed-phase gradient echo imaging sequence - and seek to explain the physical mechanisms for this paradoxical signal intensity behavior. Abdominal MR imaging at 3 T with a 3-D volumetric interpolated breath-hold (VIBE) sequence in the opposed-phase condition (TR/TE 3.3/1.3 ms) was performed in five obese boys (14{+-}2 years of age, body mass index >95th percentile for age and sex) with spectroscopically confirmed fatty livers. Two VIBE acquisitions were performed, one with and one without the use of chemical shift selective (CHESS) pulse fat suppression. The ratios of fat-suppressed over non-fat-suppressed signal intensities were assessed in regions-of-interest (ROIs) in five tissues: subcutaneous fat, liver, vertebral marrow, muscle and spleen. The boys had spectroscopically estimated hepatic fat levels between 17% and 48%. CHESS pulse fat suppression decreased subcutaneous fat signals dramatically, by more than 85% within regions of optimal fat suppression. Fatty liver signals, in contrast, were elevated by an average of 87% with CHESS pulse fat suppression. Vertebral marrow signal was also significantly elevated with CHESS pulse fat suppression, while spleen and muscle signals demonstrated only small signal increases on the order of 10%. We demonstrated that CHESS pulse fat suppression actually increases the signal intensity from fatty livers in opposed-phase gradient echo imaging conditions. The increase can be attributed to suppression of one partner of the opposed-phase pair that normally contributes to the

  4. High intensity signal of the posterior pituitary. A study with horizontal direction of frequency-encoding and fat suppression MR techniques

    International Nuclear Information System (INIS)

    Arslan, A.

    1999-01-01

    Purpose: To evaluate the consistency of fat in the high intensity signals of the normal neurohypophysis and to differentiate the high signal of posterior pituitary from that of dorsum sella. Sagittal SE T1-weighted images with frequency encoding in the horizontal direction were used in order to differentiate the high signal of posterior pituitary and dorsum sella by the vertically-oriented chemical shift artifact. Material and methods: The sellae of 46 normal volunteers were imaged with a commercially available fat suppression technique and SE sequences with frequency encoding in vertical (25 cases) and horizontal (21 cases) axes. Results: The high signal intensity was absent in 9% of the normal volunteers with no predilection to any specific age group. None of the cases with posterior pituitary high intensity signals showed suppression of the signal with fat suppression technique. A fat suppression technique was helpful in documenting the hyperintensity in 7% of normal volunteers. Nineteen of the 21 (90%) cases with high signal intensity were detected by routine SE T1-weighted images, whereas 18 of the 19 (95%) cases were detected by imaging with frequency encoding in the horizontal direction. Conclusion: The high signal does not indicate the presence of fat. Fat suppression technique and a horizontal direction of frequency encoding help in differentiating the high signal of the neurohypophysis from that of dorsum sella. (orig.)

  5. Differences in Signal Intensity and Enhancement on MR Images of the Perivascular Spaces in the Basal Ganglia versus Those in White Matter.

    Science.gov (United States)

    Naganawa, Shinji; Nakane, Toshiki; Kawai, Hisashi; Taoka, Toshiaki

    2018-01-18

    To elucidate differences between the perivascular space (PVS) in the basal ganglia (BG) versus that found in white matter (WM) using heavily T 2 -weighted FLAIR (hT 2 -FL) in terms of 1) signal intensity on non-contrast enhanced images, and 2) the degree of contrast enhancement by intravenous single dose administration of gadolinium based contrast agent (IV-SD-GBCA). Eight healthy men and 13 patients with suspected endolymphatic hydrops were included. No subjects had renal insufficiency. All subjects received IV-SD-GBCA. MR cisternography (MRC) and hT 2 -FL images were obtained prior to and 4 h after IV-SD-GBCA. The signal intensity of the PVS in the BG, subinsular WM, and the cerebrospinal fluid (CSF) in Ambient cistern (CSF AC ) and CSF in Sylvian fissure (CSF Syl ) was measured as well as that of the thalamus. The signal intensity ratio (SIR) was calculated by dividing the intensity by that of the thalamus. We used 5% as a threshold to determine the significance of the statistical test. In the pre-contrast scan, the SIR of the PVS in WM (Mean ± standard deviation, 1.83 ± 0.46) was significantly higher than that of the PVS in the BG (1.05 ± 0.154), CSF Syl (1.03 ± 0.15) and the CSF AC (0.97 ± 0.29). There was no significant difference between the SIR of the PVS in the BG compared to the CSF AC and CSF Syl . For the evaluation of the contrast enhancement effect, significant enhancement was observed in the PVS in the BG, the CSF AC and the CSF Syl compared to the pre-contrast scan. No significant contrast enhancement was observed in the PVS in WM. The signal intensity difference between the PVS in the BG versus WM on pre-contrast images suggests that the fluid composition might be different between these PVSs. The difference in the contrast enhancement between the PVSs in the BG versus WM suggests a difference in drainage function.

  6. Appearance of low signal intensity lines in MRI of silicone breast implants.

    Science.gov (United States)

    Stroman, P W; Rolland, C; Dufour, M; Grondin, P; Guidoin, R G

    1996-05-01

    Magnetic resonance (MR) images of five explanted mammary prostheses were obtained with a 1.5 T GE Signa system using a conventional spin-echo pulse sequence, in order to investigate the low-intensity curvilinear lines which may be observed in MR images of silicone gel-filled breast implants under pressure from fibrous capsules. MR images showed ellipsoid prostheses, often containing multiple low-intensity curvilinear lines which in some cases presented an appearance very similar to that of the linguine sign. Upon opening the fibrous capsules, however, all of the prostheses were found to be completely intact demonstrating that the appearance of multiple low signal intensity curvilinear lines in MR images of silicone gel-filled prostheses is not necessarily a sign of prosthesis rupture. The MR image features which are specific to the linguine sign must be more precisely defined.

  7. T2-weighted high-intensity signals in the basal ganglia as an interesting image finding in Unverricht-Lundborg disease.

    Science.gov (United States)

    Korja, Miikka; Ferlazzo, Edoardo; Soilu-Hänninen, Merja; Magaudda, Adriana; Marttila, Reijo; Genton, Pierre; Parkkola, Riitta

    2010-01-01

    We conducted a search for white matter changes (WMCs) in 13 Unverricht-Lundborg disease patients and compared the prevalence of WMCs in these patients to age-matched long-term epileptics and healthy controls. ULD patients had significantly more T2-weighted high-intensity signals on MRI than control subjects, due to the increased prevalence of these signals in the basal ganglia. Interestingly, ULD patients with the basal ganglia changes were overweight. Basal ganglia T2-weighted high-intensity signals are novel findings in ULD. 2009 Elsevier B.V. All rights reserved.

  8. Assessment of the signal intensity distribution pattern within the unruptured cerebral aneurysms using color-coded 3D MR angiography

    International Nuclear Information System (INIS)

    Satoh, Toru; Omi, Megumi; Ohsako, Chika

    2005-01-01

    To evaluate the interaction between the MR signal intensity distribution pattern and bleb formation/deformation of the aneurysmal dome, fifty cases of the unruptured cerebral aneurysms were investigated with the color-coded 3D MR angiography. Patterns were categorized into central-type, neck-type and peripheral-type according to the distribution of MR signals with low-, moderate- and high signal intensity areas. Imaging analysis revealed the significant relationship (P<0.02) of the peripheral-type aneurysms to the bleb formation and deformation of the dome, compared with those of central- and neck-type. Additionally, peripheral-type signal intensity distribution pattern was shown with aneurysms harboring relatively large dome size and lateral-type growth including internal carotid aneurysms. Prospective analysis of intraaneurysmal flow pattern with the color-coded 3D MR angiography may provide patient-specific analysis of intraaneurysmal flow status in relation to the morphological change of the corresponding aneurysmal dome in the management of unruptured cerebral aneurysms. (author)

  9. Improving the Molecular Ion Signal Intensity for In Situ Liquid SIMS Analysis.

    Science.gov (United States)

    Zhou, Yufan; Yao, Juan; Ding, Yuanzhao; Yu, Jiachao; Hua, Xin; Evans, James E; Yu, Xiaofei; Lao, David B; Heldebrant, David J; Nune, Satish K; Cao, Bin; Bowden, Mark E; Yu, Xiao-Ying; Wang, Xue-Lin; Zhu, Zihua

    2016-12-01

    In situ liquid secondary ion mass spectrometry (SIMS) enabled by system for analysis at the liquid vacuum interface (SALVI) has proven to be a promising new tool to provide molecular information at solid-liquid and liquid-vacuum interfaces. However, the initial data showed that useful signals in positive ion spectra are too weak to be meaningful in most cases. In addition, it is difficult to obtain strong negative molecular ion signals when m/z>200. These two drawbacks have been the biggest obstacle towards practical use of this new analytical approach. In this study, we report that strong and reliable positive and negative molecular signals are achievable after optimizing the SIMS experimental conditions. Four model systems, including a 1,8-diazabicycloundec-7-ene (DBU)-base switchable ionic liquid, a live Shewanella oneidensis biofilm, a hydrated mammalian epithelia cell, and an electrolyte popularly used in Li ion batteries were studied. A signal enhancement of about two orders of magnitude was obtained in comparison with non-optimized conditions. Therefore, molecular ion signal intensity has become very acceptable for use of in situ liquid SIMS to study solid-liquid and liquid-vacuum interfaces. Graphical Abstract ᅟ.

  10. Acute High-intensity Interval Exercise-induced Redox Signaling is Associated with Enhanced Insulin Sensitivity in Obese Middle-aged Men.

    Directory of Open Access Journals (Sweden)

    Lewan Parker

    2016-09-01

    Full Text Available Background. Obesity and ageing are associated with increased oxidative stress, activation of stress and mitogen activated protein kinases (SAPK, and the development of insulin resistance and metabolic disease. In contrast, acute exercise also increases oxidative stress and SAPK signaling, yet is reported to enhance insulin sensitivity and reduce the risk of metabolic disease. This study explored this paradox by investigating the effect of a single session of high-intensity interval-exercise (HIIE on redox status, muscle SAPK and insulin protein signaling in eleven middle-aged obese men. Methods. Participants completed a 2 hour hyperinsulinaemic-euglycaemic clamp at rest, and 60 minutes after HIIE (4x4 mins at 95% HRpeak; 2 min recovery periods, separated by 1-3 weeks. Results. Irrespective of exercise-induced changes to redox status, insulin stimulation both at rest and after HIIE similarly increased plasma superoxide dismutase activity, plasma catalase activity, and skeletal muscle 4-HNE; and significantly decreased plasma TBARS and hydrogen peroxide. The SAPK signaling pathways of p38 MAPK, NF-κB p65, and JNK, and the distal insulin signaling protein AS160Ser588, were activated with insulin stimulation at rest and to a greater extent with insulin stimulation after a prior bout of HIIE. Higher insulin sensitivity after HIIE was associated with higher insulin-stimulated SAPK phosphorylation (JNK, p38 MAPK and NF-κB and SOD activity (p<0.05. Conclusion. These findings support a role for redox homeostasis and SAPK signaling in insulin-stimulated glucose uptake which may contribute to the enhancement of insulin sensitivity in obese men 3 hours after HIIE.

  11. Orientation-dependent changes in MR signal intensity of articular cartilage: a manifestation of the ``magic angle`` effect

    Energy Technology Data Exchange (ETDEWEB)

    Wacker, F.K.; Bolze, X.; Felsenberg, D.; Wolf, K.J. [Department of Radiology, Benjamin Franklin University Hospital, Free University Berlin, D-12200 Berlin (Germany)

    1998-06-01

    Objective: To study magnetic resonance (MR) imaging pattern of normal hyaline articular cartilage in the knee joint with regard to the contribution of the ``magic angle`` effect to the MR signal. Design. Thirty-two healthy volunteers were imaged in a standard supine position in a 1.5-T unit using spin echo and gradient echo sequences. Nine volunteers were reimaged with the knee flexed. The signal behavior of the hyaline cartilage of the femoral condyles was evaluated qualitatively and quantitatively. The extended and flexed positions of the nine volunteers were compared. Results. A superficial and a deep hyperintense layer and a hypointense middle cartilage layer were observed. Segments of increased signal intensity were visible along the condyles; a magic angle effect on signal intensity was evident in the hypointense middle layer with both gradient echo and spin echo images. Conclusion. The MR signal behavior of hyaline cartilage is influenced by the alignment of the collagen fibers within the cartilage in relation to the magnetic field. Failure to recognize this effect may lead to inaccurate diagnosis. (orig.) With 4 figs., 17 refs.

  12. Is the BLM system ready to go to higher intensities?

    CERN Document Server

    Sapinski, M; Dehning, B; Effinger, E; Emery, J; Goddard, B; Guerrero, A; Grishin, S; Holzer, E; Jackson, S; Kurfuerst, C; Lechner, A; Marsili, A; Misiowiec, M; Nebot, E; Nordt, A; Priebe, A; Roderick, C; Schmidt, R; Verweij, A; Wenninger, J; Zamantzas, C; Zimmermann, F

    2011-01-01

    The higher beam intensities will enhance the effects of the beam losses observed during 2010 run. In particular beam losses due to so called UFO events are discussed, but also other beam loss phenomena like luminosity losses, injection losses and the leakage from the collimation system are considered. The current understanding of the quench limits reflected in the BLM thresholds on the cold magnets is presented. The thresholds for possible increased beam energy are reviewed.

  13. Hemorrhagic brain metastases with high signal intensity on diffusion-weighted MR images. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Mori, H.; Abe, O.; Aoki, S.; Masumoto, T.; Yoshikawa, T.; Kunimatsu, A; Hayashi, N.; Ohtomo, K. [Graduate School of Medicine, Univ. of Tokyo (Japan). Dept. of Radiology

    2002-11-01

    Diffusion-weighted MR imaging has been applicable to the differential diagnosis of abscesses and necrotic or cystic brain tumors. However, restricted water diffusion is not necessarily specific for brain abscess. We describe ring-enhancing metastases of lung carcinoma characterized by high signal intensity on diffusion-weighted MR images. The signal pattern probably reflected intralesional hemorrhage. The present report adds to the growing literature regarding the differential diagnosis of ring-enhancing brain lesions.

  14. Correlation between neurohypophyseal vasopressin content and signal intensity on T1-weighted magnetic resonance images. An experimental study of vasopressin depletion model using dehydrated rabbits

    International Nuclear Information System (INIS)

    Kurokawa, Hiroaki; Nakano, Yoshihisa; Ikeda, Koshi; Tanaka, Yoshimasa; Fujisawa, Ichiro

    1998-01-01

    We investigated the correlation between the signal intensity on T 1 -weighted MR images and vasopressin (VP) content in the posterior pituitary lobe. Fourteen rabbits were studied. There were 12 water-deprived rabbits (48, 72, 96, 120, 144 and 168 hours: 2 each) and 2 controls. Sagittal T 1 -weighted SE (spin-echo) MR images were obtained before and after dehydration. The signal intensity ratio of the posterior pituitary lobe to the pons was correlated with the VP content in the posterior lobe as measured by radioimmunoassay. Before water deprivation, high signal intensity in the posterior lobe was demonstrated clearly in all 14 rabbits. After water deprivation, the hyperintense signal gradually decreased and became indistinguishable from anterior lobe in four animals. The mean signal intensity ratio before water deprivation was 1.55±0.12 (mean±SD) and after water deprivation, gradually decreased over time and reached to 1.19 after 168 hours of water deprivation. Pituitary VP content and concentration decreased in parallel with the signal intensity ratio of the posterior pituitary. Significantly correlation was observed between the signal intensity ratio and VP concentration of posterior pituitary (r=0.809, p 1 -weighted image may reflect a indicator of pituitary VP content and thus may enable evaluation of disorders of water metabolism. (author)

  15. New model for gain control of signal intensity to object distance in echolocating bats

    DEFF Research Database (Denmark)

    Nørum, Ulrik; Brinkløv, Signe; Surlykke, Annemarie

    2012-01-01

    Echolocating bats emit ultrasonic calls and listen for the returning echoes to orient and localize prey in darkness. The emitted source level, SL (estimated signal intensity 10 cm from the mouth), is adjusted dynamically from call to call in response to sensory feedback as bats approach objects. ...

  16. Correlation between neurohypophyseal vasopressin content and signal intensity on T{sub 1}-weighted magnetic resonance images. An experimental study of vasopressin depletion model using dehydrated rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Kurokawa, Hiroaki; Nakano, Yoshihisa; Ikeda, Koshi; Tanaka, Yoshimasa [Kansai Medical Univ., Moriguchi, Osaka (Japan); Fujisawa, Ichiro

    1998-06-01

    We investigated the correlation between the signal intensity on T{sub 1}-weighted MR images and vasopressin (VP) content in the posterior pituitary lobe. Fourteen rabbits were studied. There were 12 water-deprived rabbits (48, 72, 96, 120, 144 and 168 hours: 2 each) and 2 controls. Sagittal T{sub 1}-weighted SE (spin-echo) MR images were obtained before and after dehydration. The signal intensity ratio of the posterior pituitary lobe to the pons was correlated with the VP content in the posterior lobe as measured by radioimmunoassay. Before water deprivation, high signal intensity in the posterior lobe was demonstrated clearly in all 14 rabbits. After water deprivation, the hyperintense signal gradually decreased and became indistinguishable from anterior lobe in four animals. The mean signal intensity ratio before water deprivation was 1.55{+-}0.12 (mean{+-}SD) and after water deprivation, gradually decreased over time and reached to 1.19 after 168 hours of water deprivation. Pituitary VP content and concentration decreased in parallel with the signal intensity ratio of the posterior pituitary. Significantly correlation was observed between the signal intensity ratio and VP concentration of posterior pituitary (r=0.809, p<0.001) . In conclusion, the results indicate that the signal intensity ratio on T{sub 1}-weighted image may reflect a indicator of pituitary VP content and thus may enable evaluation of disorders of water metabolism. (author)

  17. MRI of the normal brain from early childhood to middle age. Pt. 2. Age dependence of signal intensity changes on T2-weighted images

    International Nuclear Information System (INIS)

    Autti, T.; Raininko, R.; Vanhanen, S.L.; Kallio, M.; Santavuori, P.

    1994-01-01

    We examined 66 healthy volunteers aged 4 to 50 years by magnetic resonance imaging (MRI) and the signal intensity was measured on T2-weighted images in numerous sites and correlated with age and sex. Using distilled water and cerebrospinal fluid (CSF) as references on each slice, we calculated the signal intensities of the brain structures. Calculated ratios between structures did not change with age, except for those of the globus pallidus and thalamus, in which the signal intensities decreased more rapidly. The signal intensities of other brain structures changed equally but this could not be discerned visually and quantitative measurements were required. The signal intensities in the white and deep grey matter decreased rapidly in the first decade and then gradually to reach a plateau after the age of 18 years. Maturation of the brain thus seems to continue until near the end of the second decade of life. No sex differences were found. Quantitative analysis requires intensity references. The CSF in the tips of the frontal horns seems to be as reliable as an external fluid reference for intensity, and can be used in routine examinations provided the frontal horns are large enough to avoid partial volume effect. (orig.)

  18. Direct UV written Michelson interferometer for RZ signal generation using phase-to-intensity modulation conversion

    DEFF Research Database (Denmark)

    Peucheret, Christophe; Geng, Yan; Zsigri, Beata

    2005-01-01

    An integrated Michelson delay interferometer structure making use of waveguide gratings as reflective elements is proposed and fabricated by direct ultraviolet writing. Successful return-to-zero alternate-mark-inversion signal generation using phase-to-intensity modulation conversion...

  19. Amplification of the Signal Intensity of Fluorescence-Based Fiber-Optic Biosensors Using a Fabry-Perot Resonator Structure

    Directory of Open Access Journals (Sweden)

    Meng-Chang Hsieh

    2015-02-01

    Full Text Available Fluorescent biosensors have been widely used in biomedical applications. To amplify the intensity of fluorescence signals, this study developed a novel structure for an evanescent wave fiber-optic biosensor by using a Fabry-Perot resonator structure. An excitation light was coupled into the optical fiber through a laser-drilled hole on the proximal end of the resonator. After entering the resonator, the excitation light was reflected back and forth inside the resonator, thereby amplifying the intensity of the light in the fiber. Subsequently, the light was used to excite the fluorescent molecules in the reactive region of the sensor. The experimental results showed that the biosensor signal was amplified eight-fold when the resonator reflector was formed using a 92% reflective coating. Furthermore, in a simulation, the biosensor signal could be amplified 20-fold by using a 99% reflector.

  20. Appearance of high signal intensity and gadolinium-DTPA contrast enhancement in hypertrophied myocardium by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Yamada, Naoaki; Nagata, Seiki

    1989-01-01

    This study was undertaken to examine the potential role of magnetic resonance imaging (MRI) for evaluating myocardial tissue characterization in hypertrophic cardiomyopathy (HCM). ECG-gated MRI images were acquired in 32 HCM patients and 30 patients with hypertensive heart disease (HHD), using a 1.5 T superconducting magnet system. The thickened areas were depicted as high signal intensities in the septum of 12 HCM patients (38%) and the endocardium of 5 HHD patients (17%). Echocardiography revealed that MRI appearance of high signal intensity was associated with more thickened myocardial wall. For evaluable 16 patients receiving i.v. injection of Gd-DTPA in a dose of 0.1 mM/kg, enhancement effects were observed in 10 patients (63%). High signal intensity appearing in the hypertrophied myocardium, as well as contrast enhancement, may not be characteristic of HCM, but reflect the likelihood of myocardial degeneration associated with the hypertrophied myocardium. Although MRI may not be capable of differentiating tissue characterization in HCM from that in HHD, it may provide different information about tissue characterization in the hypertrophied myocardium from that obtained by other techniques. (N.K.)

  1. High signal intensity lesion in basal ganglia on MR imaging: correlation with portal-systemic encephalopathy in liver cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yun Ju; Choi, Sun Jeong; Kim, Chang Soo; Kim, Sun Hee; Chung, Chun Phil; Kim, Yang Sook [Maryknoll Hospital, Pusan (Korea, Republic of)

    1993-01-15

    To evaluate of the relationship between basal ganglia lesion and portal-systemic encephalopathy, eleven patients who had clinically proved liver cirrhosis with superior mesenteric vein larger than 10mm in diameter on ultrasonogram underwent brain MR imaging. No evidence of clinical or neuropsychiatric disturbance was observed in any patient at the time of the MR examination. Brain MR imaging revealed basal ganglia lesion characterized by bilateral, symmetric, high signal intensity without edema or mass effect on spin echo T1-weighted images in nine patients which included three patients with the past history of portal-systemic encephalopathy. It was concluded that excepted in the circumstances of other causes of the high signal intensity in basal ganglia on T1-weighted images such as fat, methemoglobin, melanin, neurofibromatosis, dense calcification, and parenteral nutrition, bilateral and symmetric high signal intensity lesion in basal ganglia would be a useful MR finding of subclinical portal-systemic encephalopathy in liver cirrhosis patients with no clinical or neuropsychiatric symptoms and larger than 10mm in diameter of superior mesenteric vein in ultrasonography.

  2. High signal intensity lesion in basal ganglia on MR imaging: correlation with portal-systemic encephalopathy in liver cirrhosis

    International Nuclear Information System (INIS)

    Kim, Yun Ju; Choi, Sun Jeong; Kim, Chang Soo; Kim, Sun Hee; Chung, Chun Phil; Kim, Yang Sook

    1993-01-01

    To evaluate of the relationship between basal ganglia lesion and portal-systemic encephalopathy, eleven patients who had clinically proved liver cirrhosis with superior mesenteric vein larger than 10mm in diameter on ultrasonogram underwent brain MR imaging. No evidence of clinical or neuropsychiatric disturbance was observed in any patient at the time of the MR examination. Brain MR imaging revealed basal ganglia lesion characterized by bilateral, symmetric, high signal intensity without edema or mass effect on spin echo T1-weighted images in nine patients which included three patients with the past history of portal-systemic encephalopathy. It was concluded that excepted in the circumstances of other causes of the high signal intensity in basal ganglia on T1-weighted images such as fat, methemoglobin, melanin, neurofibromatosis, dense calcification, and parenteral nutrition, bilateral and symmetric high signal intensity lesion in basal ganglia would be a useful MR finding of subclinical portal-systemic encephalopathy in liver cirrhosis patients with no clinical or neuropsychiatric symptoms and larger than 10mm in diameter of superior mesenteric vein in ultrasonography

  3. High-Intensity Interval Training Elicits Higher Enjoyment than Moderate Intensity Continuous Exercise

    Science.gov (United States)

    Thum, Jacob S.; Parsons, Gregory; Whittle, Taylor

    2017-01-01

    Exercise adherence is affected by factors including perceptions of enjoyment, time availability, and intrinsic motivation. Approximately 50% of individuals withdraw from an exercise program within the first 6 mo of initiation, citing lack of time as a main influence. Time efficient exercise such as high intensity interval training (HIIT) may provide an alternative to moderate intensity continuous exercise (MICT) to elicit substantial health benefits. This study examined differences in enjoyment, affect, and perceived exertion between MICT and HIIT. Twelve recreationally active men and women (age = 29.5 ± 10.7 yr, VO2max = 41.4 ± 4.1 mL/kg/min, BMI = 23.1 ± 2.1 kg/m2) initially performed a VO2max test on a cycle ergometer to determine appropriate workloads for subsequent exercise bouts. Each subject returned for two additional exercise trials, performing either HIIT (eight 1 min bouts of cycling at 85% maximal workload (Wmax) with 1 min of active recovery between bouts) or MICT (20 min of cycling at 45% Wmax) in randomized order. During exercise, rating of perceived exertion (RPE), affect, and blood lactate concentration (BLa) were measured. Additionally, the Physical Activity Enjoyment Scale (PACES) was completed after exercise. Results showed higher enjoyment (p = 0.013) in response to HIIT (103.8 ± 9.4) versus MICT (84.2 ± 19.1). Eleven of 12 participants (92%) preferred HIIT to MICT. However, affect was lower (pHIIT versus MICT. Although HIIT is more physically demanding than MICT, individuals report greater enjoyment due to its time efficiency and constantly changing stimulus. Trial Registration: NCT:02981667. PMID:28076352

  4. NIST mixed stain study 3: signal intensity balance in commercial short tandem repeat multiplexes.

    Science.gov (United States)

    Duewer, David L; Kline, Margaret C; Redman, Janette W; Butler, John M

    2004-12-01

    Short-tandem repeat (STR) allelic intensities were collected from more than 60 forensic laboratories for a suite of seven samples as part of the National Institute of Standards and Technology-coordinated 2001 Mixed Stain Study 3 (MSS3). These interlaboratory challenge data illuminate the relative importance of intrinsic and user-determined factors affecting the locus-to-locus balance of signal intensities for currently used STR multiplexes. To varying degrees, seven of the eight commercially produced multiplexes used by MSS3 participants displayed very similar patterns of intensity differences among the different loci probed by the multiplexes for all samples, in the hands of multiple analysts, with a variety of supplies and instruments. These systematic differences reflect intrinsic properties of the individual multiplexes, not user-controllable measurement practices. To the extent that quality systems specify minimum and maximum absolute intensities for data acceptability and data interpretation schema require among-locus balance, these intrinsic intensity differences may decrease the utility of multiplex results and surely increase the cost of analysis.

  5. GeneChip microarrays-signal intensities, RNA concentrations and probe sequences

    International Nuclear Information System (INIS)

    Binder, Hans; Preibisch, Stephan

    2006-01-01

    GeneChip microarrays consist of hundreds of thousands of oligonucleotide probes. The transformation of their signal intensities into RNA transcript concentrations requires the knowledge of the response function of the measuring device. We analysed the 'apparatus' function of perfect match (PM) and mismatched (MM) oligonucleotide probes of GeneChip microarrays after changes of the target concentration using the results of a spiked-in experiment. In agreement with previous studies we found that a competitive two-species Langmuir-adsorption model describes the probe intensities well. Each PM and MM probe is characterized by two hybridization constants which specify the propensity of the probe to bind specific and non-specific transcripts. The affinity for non-specific hybridization is on average equal for PM and MM. The purine-pyrimidine asymmetry of base pair interaction strengths, however, causes a characteristic PM-MM intensity difference, the sign of which depends on the middle base of the probe. The affinity for specific hybridization of the PM exceeds that of the MM on average by nearly one order of magnitude because the central mismatched base only weakly contributes to the stability of the probe/target duplexes. For the first time we differentiate between the free energy parameters related to the 64 possible middle-triples of DNA/RNA oligomer duplexes with a central Watson-Crick pairing and a central mismatched pairing. Both the PM and MM probes respond to the concentration of specific transcripts, which can be estimated from the PM and MM probe intensities using the Langmuir-model. The analysis of the PM-MM intensity difference provides at least no loss of accuracy and precision of the estimated concentration compared with the PM-only estimates which in turn outperform the MM-only estimates. The results show that the processing of the PM-MM intensity difference requires the consideration of a background term due to non-specific hybridization, which is

  6. Magnetic resonance angiography signal intensity as a marker of hemodynamic impairment in intracranial arterial stenosis.

    Directory of Open Access Journals (Sweden)

    Xinyi Leng

    Full Text Available Intracranial arterial stenosis (ICAS is the predominant cause of ischemic stroke and transient ischemic attack in Asia. Change of signal intensities (SI across an ICAS on magnetic resonance angiography (MRA may reflect its hemodynamic severity.In-patients with a symptomatic single ICAS detected on 3D time-of-flight MRA were recruited from 2 hospitals. Baseline and 1-year follow-up data were collected. Signal intensity ratio (SIR [ =  (mean post-stenotic SI -mean background SI/(mean pre-stenotic SI - mean background SI] was evaluated on baseline MRA to represent change of SIs across an ICAS. Acute infarct volume was measured on baseline diffusion-weighted images (DWI. Relationships between SIR and baseline characteristics as well as 1y outcomes were evaluated.Thirty-six subjects (86.1% males, mean age 55.0 were recruited. Overall, mean SIR was 0.84±0.23. Mean SIRs were not significantly different between the 23 (63.9% anatomically severe stenoses and the 13 (36.1% anatomically moderate stenoses (0.80±0.23 versus 0.92±0.21, p = 0.126. SIR was significantly, linearly and negatively correlated to acute infarct volume on DWI (Spearman correlation coefficient -0.471, p = 0.011. Two patients (5.6% had recurrent ischemic strokes at 1y, not related to SIR values.Change of signal intensities across an ICAS on MRA may reflect its hemodynamic and functional severity. Future studies are warranted to further verify the relationships between this index and prognosis of patients with symptomatic ICAS.

  7. Pump-To-Signal Intensity Modulation Transfer Characteristics in FOPAs: Modulation Frequency and Saturation Effect

    DEFF Research Database (Denmark)

    Lali-Dastjerdi, Zohreh; Cristofori, Valentina; Lund-Hansen, Toke

    2012-01-01

    This paper reports a comprehensive study of pump- to-signal intensity modulation transfer (IMT) in single-pump fiber optic parametric amplifiers (FOPAs). In particular, the IMT is studied for the first time for high-frequency fluctuations of the pump as well as in the saturated gain regime. The IMT...... cut-off frequency in typical single-pump FOPAs is around 100–200 GHz. The possibilities to shift this frequency based on dispersion and nonlinearities involved in the parametric gain are discussed. The severe IMT to the signal at low modulation frequencies can be suppressed by more than 50...

  8. Contraction-induced changes in skeletal muscle Na(+), K(+) pump mRNA expression - importance of exercise intensity and Ca(2+)-mediated signalling

    DEFF Research Database (Denmark)

    Nordsborg, Nikolai Baastrup; Kusuhara, K; Hellsten, Ylva

    2010-01-01

    Abstract Aim: To investigate if exercise intensity and Ca(2+) signalling regulate Na(+), K(+) pump mRNA expression in skeletal muscle. Methods: The importance of exercise intensity was evaluated by having trained and untrained humans perform intense intermittent and prolonged exercise. The import...

  9. Paradoxical signal pattern of mediastinal cysts on T2-weighted MR imaging: phantom and clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Ken, E-mail: k-ueda@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Yanagawa, Masahiro [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Ueguchi, Takashi [Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Satoh, Yukihisa; Kawai, Misa; Gyobu, Tomoko; Sumikawa, Hiromitsu; Honda, Osamu; Tomiyama, Noriyuki [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)

    2014-06-15

    Purpose: To evaluate the intracystic MRI (magnetic resonance imaging) signal intensity of mediastinal cystic masses on T2-weighted images. Materials and methods: A phantom study was performed to evaluate the signal intensity of a mediastinal cystic mass phantom (rubber balloon containing water) adjacent to a cardiac phantom pulsing at the rate of 60/min. T2-weighted images (sequence, fast spin echo [FSE] and single shot fast spin echo [SSFSE]) were acquired for the mediastinal cystic mass phantom. Further, a clinical study was performed in 33 patients (16 men, 17 women; age range, 19-85 years; mean, 65years) with thymic cysts or pericardial cysts. In all patients, T2-weighted images (FSE and SSFSE) were acquired. The signal intensity of cystic lesion was evaluated and was compared with that of muscle. A region of interest (ROI) was positioned on the standard MR console, and signal intensity of the cystic mass (cSI), that of the muscle (mSI), and the rate of absolute value of cSI–mSI to standard deviation (SD) of background noise (|cSI–mSI|/SD = CNR [contrast-to-noise ratio]) were measured. Results: The phantom study demonstrated that the rate phantom-ROI/saline-ROI was higher in SSFSE (0.36) than in FSE (0.19). In clinical cases, the degree of the signal intensity was higher in SSFSE than in FSE. The CNR was significantly higher in SSFSE (mean ± standard deviation, 111.0 ± 47.6) than in FSE (72.8 ± 36.6) (p < 0.001, Wilcoxon signed-rank test). Conclusions: Anterior mediastinal cysts often show lower signal intensity than the original signal intensity of water on T2-weighted images. SSFSE sequence reduces this paradoxical signal pattern on T2-weighted images, which may otherwise cause misinterpretation when assessing cystic lesions.

  10. Paradoxical signal pattern of mediastinal cysts on T2-weighted MR imaging: phantom and clinical study

    International Nuclear Information System (INIS)

    Ueda, Ken; Yanagawa, Masahiro; Ueguchi, Takashi; Satoh, Yukihisa; Kawai, Misa; Gyobu, Tomoko; Sumikawa, Hiromitsu; Honda, Osamu; Tomiyama, Noriyuki

    2014-01-01

    Purpose: To evaluate the intracystic MRI (magnetic resonance imaging) signal intensity of mediastinal cystic masses on T2-weighted images. Materials and methods: A phantom study was performed to evaluate the signal intensity of a mediastinal cystic mass phantom (rubber balloon containing water) adjacent to a cardiac phantom pulsing at the rate of 60/min. T2-weighted images (sequence, fast spin echo [FSE] and single shot fast spin echo [SSFSE]) were acquired for the mediastinal cystic mass phantom. Further, a clinical study was performed in 33 patients (16 men, 17 women; age range, 19-85 years; mean, 65years) with thymic cysts or pericardial cysts. In all patients, T2-weighted images (FSE and SSFSE) were acquired. The signal intensity of cystic lesion was evaluated and was compared with that of muscle. A region of interest (ROI) was positioned on the standard MR console, and signal intensity of the cystic mass (cSI), that of the muscle (mSI), and the rate of absolute value of cSI–mSI to standard deviation (SD) of background noise (|cSI–mSI|/SD = CNR [contrast-to-noise ratio]) were measured. Results: The phantom study demonstrated that the rate phantom-ROI/saline-ROI was higher in SSFSE (0.36) than in FSE (0.19). In clinical cases, the degree of the signal intensity was higher in SSFSE than in FSE. The CNR was significantly higher in SSFSE (mean ± standard deviation, 111.0 ± 47.6) than in FSE (72.8 ± 36.6) (p < 0.001, Wilcoxon signed-rank test). Conclusions: Anterior mediastinal cysts often show lower signal intensity than the original signal intensity of water on T2-weighted images. SSFSE sequence reduces this paradoxical signal pattern on T2-weighted images, which may otherwise cause misinterpretation when assessing cystic lesions

  11. Real-time object recognition in multidimensional images based on joined extended structural tensor and higher-order tensor decomposition methods

    Science.gov (United States)

    Cyganek, Boguslaw; Smolka, Bogdan

    2015-02-01

    In this paper a system for real-time recognition of objects in multidimensional video signals is proposed. Object recognition is done by pattern projection into the tensor subspaces obtained from the factorization of the signal tensors representing the input signal. However, instead of taking only the intensity signal the novelty of this paper is first to build the Extended Structural Tensor representation from the intensity signal that conveys information on signal intensities, as well as on higher-order statistics of the input signals. This way the higher-order input pattern tensors are built from the training samples. Then, the tensor subspaces are built based on the Higher-Order Singular Value Decomposition of the prototype pattern tensors. Finally, recognition relies on measurements of the distance of a test pattern projected into the tensor subspaces obtained from the training tensors. Due to high-dimensionality of the input data, tensor based methods require high memory and computational resources. However, recent achievements in the technology of the multi-core microprocessors and graphic cards allows real-time operation of the multidimensional methods as is shown and analyzed in this paper based on real examples of object detection in digital images.

  12. Wigner higher-order spectra: definition, properties, computation and application to transient signal analysis

    OpenAIRE

    Rodríguez Fonollosa, Javier; Nikias, Chrysostomos L.

    1993-01-01

    The Wigner higher order moment spectra (WHOS) are defined as extensions of the Wigner-Ville distribution (WD) to higher order moment spectra domains. A general class of time-frequency higher order moment spectra is also defined in terms of arbitrary higher order moments of the signal as generalizations of the Cohen’s general class of time-frequency representations. The properties of the general class of time-frequency higher order moment spectra can be related to the properties...

  13. Experimental study of MRI signal changes of calcification

    International Nuclear Information System (INIS)

    Gong Xiangyang; Li Senhua; Li Rongfen; Hong Xiang; Gong Xiaoya; Xu Fengfeng

    1999-01-01

    Objective: To evaluate MRI signal changes according to different calcium compound, concentration and proportion, and try to give an reasonable explanation. Methods: Sixty samples composed of different calcium powders, various concentration and proportion of calcium were examined with CT and MRI. Five different calcium particles were evaluated with scanning electron microscopy. Results: (1) CT value of calcium gradually increased as the concentration increased; (2) CaSO 4 ·H 2 O was similar to CaCO 3 in terms of MRI T 1 WI signal intensity (P > 0.05); (3) Ca 3 (PO 4 ) 2 and Ca(OH) 2 showed hyperintensity in T 1 WI and was higher than other calcium salts (P 1 WI signal intensity of Ca 3 (PO 4 ) 2 / and Ca(OH) 2 showed biphasic curves with their peaks at 0.3 g/ml; (5) T 2 WI signal intensity of all series of calcium decreased as the concentration increased; (6) Signal intensity of mixed Ca 3 (PO 4 ) 2 /CaCO 3 was higher than CaHPO 4 ·2H 2 O/CaCO 3 on T 1 WI and lower on T 2 WI (P 3 , CaHPO 4 ·2H 2 O and CaSO 4 ·2H 2 O showed regular crystal shapes and smooth surface under scanning electron microscopy, but Ca 3 (PO 4 ) 2 and Ca(OH) 2 displayed their irregular figures and rough surface. Conclusions: Calcifications show variable MR signal due to difference of calcium compounds, various concentration and proportion of calcium. Understanding of these finding will help interpretation of MR images more precisely

  14. A Robust Dynamic Heart-Rate Detection Algorithm Framework During Intense Physical Activities Using Photoplethysmographic Signals

    Directory of Open Access Journals (Sweden)

    Jiajia Song

    2017-10-01

    Full Text Available Dynamic accurate heart-rate (HR estimation using a photoplethysmogram (PPG during intense physical activities is always challenging due to corruption by motion artifacts (MAs. It is difficult to reconstruct a clean signal and extract HR from contaminated PPG. This paper proposes a robust HR-estimation algorithm framework that uses one-channel PPG and tri-axis acceleration data to reconstruct the PPG and calculate the HR based on features of the PPG and spectral analysis. Firstly, the signal is judged by the presence of MAs. Then, the spectral peaks corresponding to acceleration data are filtered from the periodogram of the PPG when MAs exist. Different signal-processing methods are applied based on the amount of remaining PPG spectral peaks. The main MA-removal algorithm (NFEEMD includes the repeated single-notch filter and ensemble empirical mode decomposition. Finally, HR calibration is designed to ensure the accuracy of HR tracking. The NFEEMD algorithm was performed on the 23 datasets from the 2015 IEEE Signal Processing Cup Database. The average estimation errors were 1.12 BPM (12 training datasets, 2.63 BPM (10 testing datasets and 1.87 BPM (all 23 datasets, respectively. The Pearson correlation was 0.992. The experiment results illustrate that the proposed algorithm is not only suitable for HR estimation during continuous activities, like slow running (13 training datasets, but also for intense physical activities with acceleration, like arm exercise (10 testing datasets.

  15. Signal intensity changes of normal brain at varying high b-value diffusion-weighted images using 3.0T MR scanner

    International Nuclear Information System (INIS)

    Lee, Jin Hee; Sohn, Chul Ho; Choi, Jin Soo

    2003-01-01

    Using diffusion-weighted MR imaging (DWI), to evaluate the signal intensity characteristics of normal adult brain as diffusion gradient strength (b value) increases from 1,000 to 3,000 s/mm 2 . Twenty-one healthy volunteers with neither neurologic symptoms nor pathologic findings at axial and sagittal T2-weighted MR imaging were involved in this study. All images were obtained with a 3.0T MR scanner. Six sets of spin-echo echo-planar images were acquired in the axial plane using progressively increasing strengths of diffusion-sensitizing gradients (corresponding to b values of 0, 1,000, 1,500, 2,000, 2,500, and 3,000 s/mm 2 ). All imaging parameters other than TE remained constant. Changes in normal white-gray matter signal intensity observed at variable b-value DWI were qualitatively analysed, and the signal-to-noise ratios (SNRs) in six anatomic regions (frontal and parietal white matter, genu and splenium corporis callosi, the posterior limb of the internal capsule, and the thalamus) quantitatively, and the ratios were averaged and compared with the average SNR of 1,000 s/mm DWI. As gradient strength increased from 1,000 to 3,000 s/mm 2 , both gray-and white-matter structures diminished in signal intensity, and images obtained at a b value of 3,000 s/mm 2 appeared very noisy. White matter became progressively hyperintense to gray matter as the diffusion sensitizing gradient increased, especially at the centrum semiovale, the posterior limb of the internal capsule, and the splenium corporis callosi, but the genu corporis callosi; showed exceptional intermediate low signal intensity. At quantitative assessment, the signal-to-noise ratio decreased as the diffusion sensitizing gradient increased. Relative to the images obtained at a b value of 1,000 s/mm 2 , average SNRs were 0.71 (b=1,500 s/mm 2 ), 0.52 (b=2,000 s/mm 2 ), 0.41 (b=2,500 s/mm 2 ), 0.33 (b=3,000 s/mm 2 ). As the diffusion sensitizing gradient increased, the signal-to-noise ratio of brain structures

  16. Sterilization of proteinaceous food additives by irradiation. Temperature dependent changes in intensity of ESR signals generated by electron beam irradiation

    International Nuclear Information System (INIS)

    Sakaue, Kazushi; Murata, Yoshiyuki; Higashimura, Yutaka; Hayashi, Toru; Todoriki, Setsuko; Tada, Mikiro

    1999-01-01

    Thaumatin, egg white and soybean protein were selected as samples of proteinous food additives, and changes in the intensity of signals appearing in them after they had been irradiated with electron beams were measured by ESR. It was found by such measurement that the positions of signals of thaumatin and soy proteins are nearly the same. Changes in the intensity of radicals in thaumatin calculated on the basis of the coefficients of the respective approximations obtained by using thaumatin which had been irradiated and then stored at 4degC, 25degC, 37degC and 60degC showed that there is a temperature range to determine the remaining of such radicals (inner: 19.7degC, outer: 15.23degC) and that such radicals tend to decrease straight line-wise. It was confirmed that the intensity of signals in the protein powder such thaumatin and soy protein would not be affected at the storage condition below 15degC. (author)

  17. Sterilization of proteinaceous food additives by irradiation. Temperature dependent changes in intensity of ESR signals generated by electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Sakaue, Kazushi; Murata, Yoshiyuki [Graduate School of Natural Science and Technology, Okayama Univ., Okayama (Japan); Higashimura, Yutaka [San-Ei Gen F.F.I., Inc., Osaka (Japan); Hayashi, Toru; Todoriki, Setsuko [National Food Research Institute, Ministry of Agriculture, Tsukuba, Ibaraki (Japan); Tada, Mikiro [Okayama Univ. (Japan). Faculty of Agriculture

    1999-09-01

    Thaumatin, egg white and soybean protein were selected as samples of proteinous food additives, and changes in the intensity of signals appearing in them after they had been irradiated with electron beams were measured by ESR. It was found by such measurement that the positions of signals of thaumatin and soy proteins are nearly the same. Changes in the intensity of radicals in thaumatin calculated on the basis of the coefficients of the respective approximations obtained by using thaumatin which had been irradiated and then stored at 4degC, 25degC, 37degC and 60degC showed that there is a temperature range to determine the remaining of such radicals (inner: 19.7degC, outer: 15.23degC) and that such radicals tend to decrease straight line-wise. It was confirmed that the intensity of signals in the protein powder such thaumatin and soy protein would not be affected at the storage condition below 15degC. (author)

  18. Relationship between signal intensity of blood flow in the pulmonary artery obtained by magnetic resonance imaging and results of right cardiac catheterization in patients with pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Yuguchi, Yasutoshi; Nagao, Keiichi; Kouno, Norihiro; Tanabe, Nobuhiro; Okita, Shinya; Tojima, Hirokazu; Okada, Osamu; Kuriyama, Takayuki [Chiba Univ. (Japan). School of Medicine; Yamaguchi, Tetsuo

    1992-08-01

    Electrocardiogram-gated spin-echo magnetic resonance (MR) images of the chest were obtained in five normal controls and 35 patients with pulmonary disease (11 chronic obstructive pulmonary disease, 6 pulmonary thromboembolism, 5 primary pulmonary hypertension, 4 interstitial pulmonary disease, 4 pulmonary hypertension with disturbance of portal circulation, and 5 other diseases) who underwent right cardiac catheterization. In transverse images at the level of the right main pulmonary artery (rPA) and sagittal images at the level through the midsternal line and the spinal cord, the signal intensity of blood flow in the rPA was quantitatively evaluated, and the correlations with the MR signal intensity of intravascular flow and the parameters of hemodynamics were studied. In diastole MR images of both normal controls and patients mostly showed a significant signal and visible flow images. In systolic MR images, the mean values of hemodynamic parameters (mean pulmonary arterial pressure (mPAP), pulmonary arteriolar resistance (PAR), and cardiac index (CI)) were abnormal in patients with significant signal intensity of flow compared with those in patients without sufficient MR signal. The signal intensity was not correlated with mPAP; however, it significantly increased as PAR increased, and it increased as CI decreased both in diastole and in systole. Especially in systole, there was good correlation between the signal intensity in transverse MR images and CI and between signal intensity in sagittal MR images and PAR . These results suggest that the signal intensity of blood flow in the rPA on MR images can be used as an index of the severity of right heart failure associated with pulmonary disease. MR imaging is a useful modality to evaluate pulmonary circulation disturbance because of its ability to assess blood flow in the pulmonary artery noninvasively without interference from other structures such as bone and normal lung. (J.P.N.).

  19. Optimized Signaling Method for High-Speed Transmission Channels with Higher Order Transfer Function

    Science.gov (United States)

    Ševčík, Břetislav; Brančík, Lubomír; Kubíček, Michal

    2017-08-01

    In this paper, the selected results from testing of optimized CMOS friendly signaling method for high-speed communications over cables and printed circuit boards (PCBs) are presented and discussed. The proposed signaling scheme uses modified concept of pulse width modulated (PWM) signal which enables to better equalize significant channel losses during data high-speed transmission. Thus, the very effective signaling method to overcome losses in transmission channels with higher order transfer function, typical for long cables and multilayer PCBs, is clearly analyzed in the time and frequency domain. Experimental results of the measurements include the performance comparison of conventional PWM scheme and clearly show the great potential of the modified signaling method for use in low power CMOS friendly equalization circuits, commonly considered in modern communication standards as PCI-Express, SATA or in Multi-gigabit SerDes interconnects.

  20. Unusual signal intensity of congenital pulmonary airway malformation on fetal magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Owada, Keiho; Miyazaki, Osamu; Nosaka, Shunsuke [National Center for Child Health and Development, Department of Radiology, Tokyo (Japan); Matsuoka, Kentaro [National Center for Child Health and Development, Department of Pathology, Tokyo (Japan); Sago, Haruhiko [National Center for Child Health and Development, Department of Perinatal Medicine and Maternal Care, Tokyo (Japan)

    2015-05-01

    Congenital pulmonary airway malformation (CPAM) is classified into pathologically different types. These types are sometimes distinguishable by fetal lung MRI and are usually observed as higher-signal lesions on T2-weighted images than normal lung. We describe a case of unusual CPAM resembling neoplasms, with a lower signal than is found in normal lung. Histopathology showed a large number of mucogenic cells but found no evidence that could explain this feature on fetal MRI. An unusual low-signal mass associated with a pulmonary cyst in fetal lung on MRI may suggest an unusual type 1 CPAM. (orig.)

  1. Unusual signal intensity of congenital pulmonary airway malformation on fetal magnetic resonance imaging

    International Nuclear Information System (INIS)

    Owada, Keiho; Miyazaki, Osamu; Nosaka, Shunsuke; Matsuoka, Kentaro; Sago, Haruhiko

    2015-01-01

    Congenital pulmonary airway malformation (CPAM) is classified into pathologically different types. These types are sometimes distinguishable by fetal lung MRI and are usually observed as higher-signal lesions on T2-weighted images than normal lung. We describe a case of unusual CPAM resembling neoplasms, with a lower signal than is found in normal lung. Histopathology showed a large number of mucogenic cells but found no evidence that could explain this feature on fetal MRI. An unusual low-signal mass associated with a pulmonary cyst in fetal lung on MRI may suggest an unusual type 1 CPAM. (orig.)

  2. Transluminal color-coded three-dimensional magnetic resonance angiography for visualization of signal Intensity distribution pattern within an unruptured cerebral aneurysm: preliminarily assessment with anterior communicating artery aneurysms

    International Nuclear Information System (INIS)

    Satoh, T.; Ekino, C.; Ohsako, C.

    2004-01-01

    The natural history of unruptured cerebral aneurysm is not known; also unknown is the potential growth and rupture in any individual aneurysm. The authors have developed transluminal color-coded three-dimensional magnetic resonance angiography (MRA) obtained by a time-of-flight sequence to investigate the interaction between the intra-aneurysmal signal intensity distribution patterns and configuration of unruptured cerebral aneurysms. Transluminal color-coded images were reconstructed from volume data of source magnetic resonance angiography by using a parallel volume-rendering algorithm with transluminal imaging technique. By selecting a numerical threshold range from a signal intensity opacity chart of the three-dimensional volume-rendering dataset several areas of signal intensity were depicted, assigned different colors, and visualized transparently through the walls of parent arteries and an aneurysm. Patterns of signal intensity distribution were analyzed with three operated cases of an unruptured anterior communicating artery aneurysm and compared with the actual configurations observed at microneurosurgery. A little difference in marginal features of an aneurysm was observed; however, transluminal color-coded images visualized the complex signal intensity distribution within an aneurysm in conjunction with aneurysmal geometry. Transluminal color-coded three-dimensional magnetic resonance angiography can thus provide numerical analysis of the interaction between spatial signal intensity distribution patterns and aneurysmal configurations and may offer an alternative and practical method to investigate the patient-specific natural history of individual unruptured cerebral aneurysms. (orig.)

  3. Optimizing signal intensity correction during evaluation of hepatic parenchymal enhancement on gadoxetate disodium-enhanced MRI: Comparison of three methods

    International Nuclear Information System (INIS)

    Onoda, Minori; Hyodo, Tomoko; Murakami, Takamichi; Okada, Masahiro; Uto, Tatsuro; Hori, Masatoshi; Miyati, Tosiaki

    2015-01-01

    Highlights: •Signal intensity is often used to evaluate hepatic enhancement with Gd-EOB-DTPA in the hepatobiliary phase. •Comparison of uncorrected signal intensity with T 1 value revealed signal intensity instability. •Measurement of uncorrected liver SI or SNR often yields erroneous results on late-phase gadoxetate MRI due to shimming and other optimization techniques. •Signal intensity corrected by scale and rescale slope from DICOM data gave comparable results. -- Abstract: Objective: To compare signal intensity (SI) correction using scale and rescale slopes with SI correction using SIs of spleen and muscle for quantifying multiphase hepatic contrast enhancement with Gd-EOB-DTPA by assessing their correlation with T 1 values generated from Look-Locker turbo-field-echo (LL-TFE) sequence data (ER-T 1 ). Materials and methods: Thirty patients underwent Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) in this prospective clinical study. For each patient, breath-hold T 1 -weighted fat-suppressed three-dimensional (3D) gradient echo sequences (e-THRIVE) were acquired before and 2 (first phase), 10 (second phase), and 20 min (third phase) after intravenous Gd-EOB-DTPA. Look-Locker turbo-field-echo (LL-TFE) sequences were acquired before and 1.5 (first phase), 8 (second phase), and 18 min (third phase) postcontrast. The liver parenchyma enhancement ratios (ER) of each phase were calculated using the SI from e-THRIVE sequences (ER-SI) and the T 1 values generated from LL-TFE sequence data (ER-T 1 ) respectively. ER-SIs were calculated in three ways: (1) comparing with splenic SI (ER-SI-s), (2) comparing with muscle SI (ER-SI-m), (3) using scale and rescale slopes obtained from DICOM headers (ER-SI-c), to eliminate the effects of receiver gain and scaling. For each of the first, second and third phases, correlation and agreement were assessed between each ER-SI and ER-T 1 . Results: In the first phase, all ER-SIs correlated weakly with ER-T 1 . In the second

  4. MR imaging of renal cell carcinoma. Associations among signal intensity, tumor enhancement, and pathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Yabuki, Takayuki; Togami, Izumi; Kitagawa, Takahiro; Sasai, Nobuya; Tsushima, Tomoyasu; Shirasaki, Yoshinori; Hiraki, Yoshio [Okayama Univ. (Japan). Graduate School of Medicine and Dentistry

    2003-08-01

    The purpose of this study was to compare the MR characteristics of renal cell carcinomas against histologic findings and to assess the correlations among signal intensity, tumor enhancement, and pathologic findings. Fifty-four patients (56 lesions) were examined by MR imaging and then underwent partial or radical nephrectomy. The pathologic diagnosis of all lesions was renal cell carcinoma. All MR examinations were performed as dynamic studies using the same 1.5-T scanner. MR characteristics were compared against pathologic findings after resection, and the correlations among signal intensity, tumor enhancement, and pathologic findings were then assessed. A significant correlation was observed between tumor grade and tumor enhancement, with G3 lesions tending to show little enhancement. Regardless of the histologic classification, G3 tumors were found to contain highly heterotypic cancer cells and very few vessels by histopathologic examination. No significant correlations were noted between the other MR characteristics and pathologic findings. Renal cell carcinomas showing little enhancement tend to be highly malignant lesions based on the pathologic findings. Special consideration is required for these tumors with regard to the selection of surgical intervention and follow-up observation. (author)

  5. MR imaging of renal cell carcinoma. Associations among signal intensity, tumor enhancement, and pathologic findings

    International Nuclear Information System (INIS)

    Yabuki, Takayuki; Togami, Izumi; Kitagawa, Takahiro; Sasai, Nobuya; Tsushima, Tomoyasu; Shirasaki, Yoshinori; Hiraki, Yoshio

    2003-01-01

    The purpose of this study was to compare the MR characteristics of renal cell carcinomas against histologic findings and to assess the correlations among signal intensity, tumor enhancement, and pathologic findings. Fifty-four patients (56 lesions) were examined by MR imaging and then underwent partial or radical nephrectomy. The pathologic diagnosis of all lesions was renal cell carcinoma. All MR examinations were performed as dynamic studies using the same 1.5-T scanner. MR characteristics were compared against pathologic findings after resection, and the correlations among signal intensity, tumor enhancement, and pathologic findings were then assessed. A significant correlation was observed between tumor grade and tumor enhancement, with G3 lesions tending to show little enhancement. Regardless of the histologic classification, G3 tumors were found to contain highly heterotypic cancer cells and very few vessels by histopathologic examination. No significant correlations were noted between the other MR characteristics and pathologic findings. Renal cell carcinomas showing little enhancement tend to be highly malignant lesions based on the pathologic findings. Special consideration is required for these tumors with regard to the selection of surgical intervention and follow-up observation. (author)

  6. Correlation of histological examination of meniscus with MR images; Focused on high signal intensity of the meniscus not caused by definite meniscal tear and impact on MR diagnosis of tears

    Energy Technology Data Exchange (ETDEWEB)

    Li, Chun Ai; Kim, Min Ki; Kim, In Hwan; Lee, Ju Hong; Jang, Kyu Yun; Lee, Sang Yong [Chonbuk National University Hospital, Chonbuk National University College of Medicine, Jeonju (Korea, Republic of)

    2013-12-15

    To document the causes of high signal intensity of the meniscus which is not caused by definite meniscal tears on MR imaging, through correlation with histological examination. For the correlation between the MR image and histology, we obtained prospectively 31 meniscal specimens from 21 patients. Proton density-weighted turbo spin-echo MR images were used. Minimal tear, thinning of the lamellar layer, degeneration of the central layer, and radial tie fibers were detected upon histological examination, and were correlated with the corresponding MR images. Minimal tear of the lamellar layer was seen in 60 zones out of 100 slides. On MR images, 29 (48.3%) of these 60 zones had high signal intensity. Thinning of the lamellar layer was seen in 24 zones, with 7 (29.2%) having high signal intensity. 57 central zones showed degenerative change in the central layer and high signal intensity on all corresponding MR images. Radial tie fibers in the central layer appeared as high signal intensity areas. Minimal tear and thinning of the lamellar layer, degeneration and radial tie fibers of the central layer of the meniscus cause high signal intensity on MR images.

  7. Stochastic resonance in a time-delayed asymmetric bistable system with mixed periodic signal

    International Nuclear Information System (INIS)

    Yong-Feng, Guo; Wei, Xu; Liang, Wang

    2010-01-01

    This paper studies the phenomenon of stochastic resonance in an asymmetric bistable system with time-delayed feedback and mixed periodic signal by using the theory of signal-to-noise ratio in the adiabatic limit. A general approximate Fokker–Planck equation and the expression of the signal-to-noise ratio are derived through the small time delay approximation at both fundamental harmonics and mixed harmonics. The effects of the additive noise intensity Q, multiplicative noise intensity D, static asymmetry r and delay time τ on the signal-to-noise ratio are discussed. It is found that the higher mixed harmonics and the static asymmetry r can restrain stochastic resonance, and the delay time τ can enhance stochastic resonance. Moreover, the longer the delay time τ is, the larger the additive noise intensity Q and the multiplicative noise intensity D are, when the stochastic resonance appears. (general)

  8. Transient global amnesia: increased signal intensity in the right hippocampus on diffusion-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, M.; Sakamoto, S.; Ishii, K. [Division of Neuroimaging Research, Hyogo Institute for Aging Brain and Cognitive Disorders (Japan); Imamura, T.; Kazui, H.; Mori, E. [Division of Clinical Neurosciences, Hyogo Institute for Aging Brain and Cognitive Disorders, Hyogo (Japan)

    2002-03-01

    We report on a patient with pure transient global amnesia (TGA) whose magnetic resonance imaging (MRI) demonstrated a small region of increased signal intensity in the right hippocampus on diffusion-weighted imaging (DWI). DWI was sensitive and useful for evaluating the early stage of TGA and might help to explain the pathophysiology of TGA. (orig.)

  9. Transient global amnesia: increased signal intensity in the right hippocampus on diffusion-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    Matsui, M.; Sakamoto, S.; Ishii, K.; Imamura, T.; Kazui, H.; Mori, E.

    2002-01-01

    We report on a patient with pure transient global amnesia (TGA) whose magnetic resonance imaging (MRI) demonstrated a small region of increased signal intensity in the right hippocampus on diffusion-weighted imaging (DWI). DWI was sensitive and useful for evaluating the early stage of TGA and might help to explain the pathophysiology of TGA. (orig.)

  10. Analysis of EMG Signals in Aggressive and Normal Activities by Using Higher-Order Spectra

    Directory of Open Access Journals (Sweden)

    Necmettin Sezgin

    2012-01-01

    Full Text Available The analysis and classification of electromyography (EMG signals are very important in order to detect some symptoms of diseases, prosthetic arm/leg control, and so on. In this study, an EMG signal was analyzed using bispectrum, which belongs to a family of higher-order spectra. An EMG signal is the electrical potential difference of muscle cells. The EMG signals used in the present study are aggressive or normal actions. The EMG dataset was obtained from the machine learning repository. First, the aggressive and normal EMG activities were analyzed using bispectrum and the quadratic phase coupling of each EMG episode was determined. Next, the features of the analyzed EMG signals were fed into learning machines to separate the aggressive and normal actions. The best classification result was 99.75%, which is sufficient to significantly classify the aggressive and normal actions.

  11. Analysis of EMG Signals in Aggressive and Normal Activities by Using Higher-Order Spectra

    Science.gov (United States)

    Sezgin, Necmettin

    2012-01-01

    The analysis and classification of electromyography (EMG) signals are very important in order to detect some symptoms of diseases, prosthetic arm/leg control, and so on. In this study, an EMG signal was analyzed using bispectrum, which belongs to a family of higher-order spectra. An EMG signal is the electrical potential difference of muscle cells. The EMG signals used in the present study are aggressive or normal actions. The EMG dataset was obtained from the machine learning repository. First, the aggressive and normal EMG activities were analyzed using bispectrum and the quadratic phase coupling of each EMG episode was determined. Next, the features of the analyzed EMG signals were fed into learning machines to separate the aggressive and normal actions. The best classification result was 99.75%, which is sufficient to significantly classify the aggressive and normal actions. PMID:23193379

  12. Honest signaling in trust interactions: smiles rated as genuine induce trust and signal higher earning opportunities

    OpenAIRE

    Centorrino, S.; Djemai, E.; Hopfensitz, A.; Milinski, M.; Seabright, P.

    2015-01-01

    We test the hypothesis that smiles perceived as honest serve as a signal that has evolved to induce cooperation in situations requiring mutual trust. Potential trustees (84 participants from Toulouse, France) made two video clips averaging around 15 seconds for viewing by potential senders before the latter decided whether to ‘send’ or ‘keep’ a lower stake (4 euros) or higher stake (8 euros). Senders (198 participants from Lyon, France) made trust decisions with respect to the recorded clips....

  13. Intensive removal of signal crayfish (Pacifastacus leniusculus) from rivers increases numbers and taxon richness of macroinvertebrate species.

    Science.gov (United States)

    Moorhouse, Tom P; Poole, Alison E; Evans, Laura C; Bradley, David C; Macdonald, David W

    2014-02-01

    Invasive species are a major cause of species extinction in freshwater ecosystems, and crayfish species are particularly pervasive. The invasive American signal crayfish Pacifastacus leniusculus has impacts over a range of trophic levels, but particularly on benthic aquatic macroinvertebrates. Our study examined the effect on the macroinvertebrate community of removal trapping of signal crayfish from UK rivers. Crayfish were intensively trapped and removed from two tributaries of the River Thames to test the hypothesis that lowering signal crayfish densities would result in increases in macroinvertebrate numbers and taxon richness. We removed 6181 crayfish over four sessions, resulting in crayfish densities that decreased toward the center of the removal sections. Conversely in control sections (where crayfish were trapped and returned), crayfish density increased toward the center of the section. Macroinvertebrate numbers and taxon richness were inversely correlated with crayfish densities. Multivariate analysis of the abundance of each taxon yielded similar results and indicated that crayfish removals had positive impacts on macroinvertebrate numbers and taxon richness but did not alter the composition of the wider macroinvertebrate community. Synthesis and applications: Our results demonstrate that non-eradication-oriented crayfish removal programmes may lead to increases in the total number of macroinvertebrates living in the benthos. This represents the first evidence that removing signal crayfish from riparian systems, at intensities feasible during control attempts or commercial crayfishing, may be beneficial for a range of sympatric aquatic macroinvertebrates.

  14. Optimizing signal intensity correction during evaluation of hepatic parenchymal enhancement on gadoxetate disodium-enhanced MRI: Comparison of three methods

    Energy Technology Data Exchange (ETDEWEB)

    Onoda, Minori, E-mail: onoda@radt.med.kindai.ac.jp [Department of Radiological Technology, Kinki University Hospital, 377-2 Ohno-Higashi, Osaka-Sayama, Osaka 589-8511 (Japan); Division of Health Sciences, Graduate School of Medical Science, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942 (Japan); Hyodo, Tomoko, E-mail: neneth@m.ehime-u.ac.jp [Department of Radiology, Kinki University Faculty of Medicine, 377-2 Ohno-Higashi, Osaka-Sayama, Osaka 589-8511 (Japan); Murakami, Takamichi, E-mail: murakami@med.kindai.ac.jp [Department of Radiology, Kinki University Faculty of Medicine, 377-2 Ohno-Higashi, Osaka-Sayama, Osaka 589-8511 (Japan); Okada, Masahiro, E-mail: okada777@med.u-ryukyu.ac.jp [Department of Radiology, Kinki University Faculty of Medicine, 377-2 Ohno-Higashi, Osaka-Sayama, Osaka 589-8511 (Japan); Uto, Tatsuro, E-mail: chuho@med.kindai.ac.jp [Department of Radiological Technology, Kinki University Hospital, 377-2 Ohno-Higashi, Osaka-Sayama, Osaka 589-8511 (Japan); Hori, Masatoshi, E-mail: mhori@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan); Miyati, Tosiaki, E-mail: ramiyati@mhs.mp.kanazawa-u.ac.jp [Division of Health Sciences, Graduate School of Medical Science, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942 (Japan)

    2015-03-15

    Highlights: •Signal intensity is often used to evaluate hepatic enhancement with Gd-EOB-DTPA in the hepatobiliary phase. •Comparison of uncorrected signal intensity with T{sub 1} value revealed signal intensity instability. •Measurement of uncorrected liver SI or SNR often yields erroneous results on late-phase gadoxetate MRI due to shimming and other optimization techniques. •Signal intensity corrected by scale and rescale slope from DICOM data gave comparable results. -- Abstract: Objective: To compare signal intensity (SI) correction using scale and rescale slopes with SI correction using SIs of spleen and muscle for quantifying multiphase hepatic contrast enhancement with Gd-EOB-DTPA by assessing their correlation with T{sub 1} values generated from Look-Locker turbo-field-echo (LL-TFE) sequence data (ER-T{sub 1}). Materials and methods: Thirty patients underwent Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) in this prospective clinical study. For each patient, breath-hold T{sub 1}-weighted fat-suppressed three-dimensional (3D) gradient echo sequences (e-THRIVE) were acquired before and 2 (first phase), 10 (second phase), and 20 min (third phase) after intravenous Gd-EOB-DTPA. Look-Locker turbo-field-echo (LL-TFE) sequences were acquired before and 1.5 (first phase), 8 (second phase), and 18 min (third phase) postcontrast. The liver parenchyma enhancement ratios (ER) of each phase were calculated using the SI from e-THRIVE sequences (ER-SI) and the T{sub 1} values generated from LL-TFE sequence data (ER-T{sub 1}) respectively. ER-SIs were calculated in three ways: (1) comparing with splenic SI (ER-SI-s), (2) comparing with muscle SI (ER-SI-m), (3) using scale and rescale slopes obtained from DICOM headers (ER-SI-c), to eliminate the effects of receiver gain and scaling. For each of the first, second and third phases, correlation and agreement were assessed between each ER-SI and ER-T{sub 1}. Results: In the first phase, all ER-SIs correlated

  15. Primary Study about Intensity Signal of Electron Paramagnetic Resonance in vivo Tooth Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hoon; Gang, Seo Gon; Kim, Jeong In; Lee, Byung Il [KHNP Radiation Health Institute, Gyeongju (Korea, Republic of)

    2017-04-15

    The signal of Electron Paramagnetic Resonance(EPR) dosimetry system using human tooth has been well introduced as one of the efficient tool to evaluate radiation exposure. But, EPR dosimetry, even in the case of classical in vitro EPR system using tooth sample(measured molars), was regarded as having big signal fluctuation. One of reason for such difficulty in getting accurate intensity was the big effect of organic materials mixed in enamel part of teeth samples. They are mainly caused by the adaptation process of system itself to the movement of measured human subject. Generally, when we measured human teeth in vivo, five of six teeth spectrum were gathered and averaged for real evaluation. The these spectrum are measured under very different environment like angle of external magnet making magnetic filed with teeth(incisor). Random movement of these signals should be considered in different view point to understand and compare each EPR in vivo EPR spectrum. The peak to peak value of obtained five or six in vivo EPR system to get averaged value for final quantity of free radicals in hydroxy apatite crystal construction in enamel part of human teeth looks so randomly changed without regulation. But, in overall view, the EPR signal, especially at no irradiation level, is almost same for every measurement trial which is mainly composed of big noise and very small signal from real free radicals. The peak to peak value of obtained five or six in vivo EPR system to get averaged value for final quantity of free radicals in hydroxy apatite crystal construction in enamel part of human teeth looks so randomly changed without regulation.

  16. Primary Study about Intensity Signal of Electron Paramagnetic Resonance in vivo Tooth Dosimetry

    International Nuclear Information System (INIS)

    Choi, Hoon; Gang, Seo Gon; Kim, Jeong In; Lee, Byung Il

    2017-01-01

    The signal of Electron Paramagnetic Resonance(EPR) dosimetry system using human tooth has been well introduced as one of the efficient tool to evaluate radiation exposure. But, EPR dosimetry, even in the case of classical in vitro EPR system using tooth sample(measured molars), was regarded as having big signal fluctuation. One of reason for such difficulty in getting accurate intensity was the big effect of organic materials mixed in enamel part of teeth samples. They are mainly caused by the adaptation process of system itself to the movement of measured human subject. Generally, when we measured human teeth in vivo, five of six teeth spectrum were gathered and averaged for real evaluation. The these spectrum are measured under very different environment like angle of external magnet making magnetic filed with teeth(incisor). Random movement of these signals should be considered in different view point to understand and compare each EPR in vivo EPR spectrum. The peak to peak value of obtained five or six in vivo EPR system to get averaged value for final quantity of free radicals in hydroxy apatite crystal construction in enamel part of human teeth looks so randomly changed without regulation. But, in overall view, the EPR signal, especially at no irradiation level, is almost same for every measurement trial which is mainly composed of big noise and very small signal from real free radicals. The peak to peak value of obtained five or six in vivo EPR system to get averaged value for final quantity of free radicals in hydroxy apatite crystal construction in enamel part of human teeth looks so randomly changed without regulation.

  17. Maximal intensity higher-order Akhmediev breathers of the nonlinear Schrödinger equation and their systematic generation

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Siu A., E-mail: chin@physics.tamu.edu [Department of Physics and Astronomy, Texas A& M University, College Station, TX 77843 (United States); Ashour, Omar A. [Department of Physics and Astronomy, Texas A& M University, College Station, TX 77843 (United States); Science Program, Texas A& M University at Qatar, P.O. Box 23874 Doha (Qatar); Nikolić, Stanko N. [Science Program, Texas A& M University at Qatar, P.O. Box 23874 Doha (Qatar); Institute of Physics, University of Belgrade, Pregrevica 118, 11080 Belgrade (Serbia); Belić, Milivoj R. [Science Program, Texas A& M University at Qatar, P.O. Box 23874 Doha (Qatar)

    2016-10-23

    It is well known that Akhmediev breathers of the nonlinear cubic Schrödinger equation can be superposed nonlinearly via the Darboux transformation to yield breathers of higher order. Surprisingly, we find that the peak height of each Akhmediev breather only adds linearly to form the peak height of the final breather. Using this peak-height formula, we show that at any given periodicity, there exists a unique high-order breather of maximal intensity. Moreover, these high-order breathers form a continuous hierarchy, growing in intensity with increasing periodicity. For any such higher-order breather, a simple initial wave function can be extracted from the Darboux transformation to dynamically generate that breather from the nonlinear Schrödinger equation. - Highlights: • Proved an analytical formula for the peak-height of an nth-order Akhmediev breather. • Constructed nth-order Akhmediev breathers of maximal peak intensity. • Extracted initial wave functions that can be used experimentally to produce these maximal breathers in optical fibers.

  18. MR imaging of renal cell carcinoma: associations among signal intensity, tumor enhancement, and pathologic findings.

    OpenAIRE

    Yabuki, Takayuki; Togami, Izumi; Kitagawa, Takahiro; Sasai, Nobuya; Tsushima, Tomoyasu; Shirasaki, Yoshinori; Hiraki, Yoshio

    2003-01-01

    The purpose of this study was to compare the MR characteristics of renal cell carcinomas against histologic findings and to assess the correlations among signal intensity, tumor enhancement, and pathologic findings. Fifty-four patients (56 lesions) were examined by MR imaging and then underwent partial or radical nephrectomy. The pathologic diagnosis of all lesions was renal cell carcinoma. All MR examinations were performed as dynamic studies using the same 1.5-T scanner. MR characteristics ...

  19. Quantification of Parkinson Tremor Intensity Based On EMG Signal Analysis Using Fast Orthogonal Search Algorithm

    Directory of Open Access Journals (Sweden)

    H. Rezghian Moghadam

    2018-06-01

    Full Text Available The tremor injury is one of the common symptoms of Parkinson's disease. The patients suffering from Parkinson's disease have difficulty in controlling their movements owing to tremor. The intensity of the disease can be determined through specifying the range of intensity values of involuntary tremor in Parkinson patients. The level of disease in patients is determined through an empirical range of 0-5. In the early stages of Parkinson, resting tremor can be very mild and intermittent. So, diagnosing the levels of disease is difficult but important since it has only medication therapy. The aim of this study is to quantify the intensity of tremor by the analysis of electromyogram signal. The solution proposed in this paper is to employ a polynomial function model to estimate the Unified Parkinson's Disease Rating Scale (UPDRS value. The algorithm of Fast Orthogonal Search (FOS, which is based on identification of orthogonal basic functions, was utilized for model identification. In fact, some linear and nonlinear features extracted from wrist surface electromyogram signal were considered as the input of the model identified by FOS, and the model output was the UPDRS value. In this research, the proposed model was designed based on two different structures which have been called the single structure and parallel structure. The efficiency of designed models with different structures was evaluated. The evaluation results using K-fold cross validation approach showed that the proposed model with a parallel structure could determine the tremor severity of the Parkinson's disease with accuracy of 99.25% ±0.41, sensitivity of 97.17% ±1.9 and specificity of 99.72% ±0.18.

  20. Effect of sample storage time on detection of hybridization signals in Checkerboard DNA-DNA hybridization.

    Science.gov (United States)

    do Nascimento, Cássio; Muller, Katia; Sato, Sandra; Albuquerque Junior, Rubens Ferreira

    2012-04-01

    Long-term sample storage can affect the intensity of the hybridization signals provided by molecular diagnostic methods that use chemiluminescent detection. The aim of this study was to evaluate the effect of different storage times on the hybridization signals of 13 bacterial species detected by the Checkerboard DNA-DNA hybridization method using whole-genomic DNA probes. Ninety-six subgingival biofilm samples were collected from 36 healthy subjects, and the intensity of hybridization signals was evaluated at 4 different time periods: (1) immediately after collecting (n = 24) and (2) after storage at -20 °C for 6 months (n = 24), (3) for 12 months (n = 24), and (4) for 24 months (n = 24). The intensity of hybridization signals obtained from groups 1 and 2 were significantly higher than in the other groups (p  0.05). The Checkerboard DNA-DNA hybridization method was suitable to detect hybridization signals from all groups evaluated, and the intensity of signals decreased significantly after long periods of sample storage.

  1. Repeated intravenous administration of gadobutrol does not lead to increased signal intensity on unenhanced T1-weighted images - a voxel-based whole brain analysis

    Energy Technology Data Exchange (ETDEWEB)

    Langner, Soenke; Kromrey, Marie-Luise [University Medicine Greifswald, Institute of Diagnostic Radiology and Neuroradiology, Greifswald (Germany); Kuehn, Jens-Peter [University Medicine Greifswald, Institute of Diagnostic Radiology and Neuroradiology, Greifswald (Germany); University Hospital, Carl Gustav Carus University Dresden, Institute for Radiology, Dresden (Germany); Grothe, Matthias [University Medicine Greifswald, Department of Neurology, Greifswald (Germany); Domin, Martin [University Medicine Greifswald, Functional Imaging Unit, Institute of Diagnostic Radiology and Neuroradiology, Greifswald (Germany)

    2017-09-15

    To identify a possible association between repeated intravenous administration of gadobutrol and increased signal intensity in the grey and white matter using voxel-based whole-brain analysis. In this retrospective single-centre study, 217 patients with a clinically isolated syndrome underwent baseline brain magnetic resonance imaging and at least one annual follow-up examination with intravenous administration of 0.1 mmol/kg body weight of gadobutrol. Using the ''Diffeomorphic Anatomical Registration using Exponentiated Lie algebra'' (DARTEL) normalisation process, tissue templates for grey matter (GM), white matter (WM), and cerebrospinal fluid (CSF) were calculated, as were GM-CSF and WM-CSF ratios. Voxel-based whole-brain analysis was used to calculate the signal intensity for each voxel in each data set. Paired t-test was applied to test differences to baseline MRI for significance. Voxel-based whole-brain analysis demonstrated no significant changes in signal intensity of grey and white matter after up to five gadobutrol administrations. There was no significant change in GM-CSF and grey WM-CSF ratios. Voxel-based whole-brain analysis did not demonstrate increased signal intensity of GM and WM on unenhanced T1-weighted images after repeated gadobutrol administration. The molecular structure of gadolinium-based contrast agent preparations may be an essential factor causing SI increase on unenhanced T1-weighted images. (orig.)

  2. Higher intramuscular triacylglycerol in women does not impair insulin sensitivity and proximal insulin signaling

    DEFF Research Database (Denmark)

    Høeg, Louise; Roepstorff, Carsten; Thiele, Maja

    2009-01-01

    that despite 47% higher IMTG levels in women in the follicular phase whole body as well as leg insulin sensitivity are higher than in matched men. This was not explained by sex differences in proximal insulin signalling in women. In women it seems that a high capillary density and type 1 muscle fiber...... expression may be important for insulin action. Key words: Muscle Triglycerides, gender, insulin action, sex paradox....

  3. Thirty Minutes of Running Exercise Decreases T2 Signal Intensity but Not Thickness of the Knee Joint Cartilage: A 3.0-T Magnetic Resonance Imaging Study.

    Science.gov (United States)

    Karanfil, Yiğitcan; Babayeva, Naila; Dönmez, Gürhan; Diren, H Barış; Eryılmaz, Muzaffer; Doral, Mahmut Nedim; Korkusuz, Feza

    2018-04-01

    Objective Recent studies showed a potential of magnetic resonance imaging (MRI), which can be used as an additional tool for diagnosing cartilage degeneration in the early stage. We designed a cross-sectional study in order to evaluate knee joint cartilage adaptation to running, using 3.0-T MRI equipped with the 3-dimensional turbo spin echo (VISTA = Volume ISotropic Turbo spin echo Acquisition) software. By this thickness (mm) and signal intensity (mean pixel value) can be quantified, which could be closely related to the fluid content of the knee joint cartilage, before and after running. Methods A total of 22 males, aged 18 to 35 years, dominant (right) and nondominant (left) knees were assessed before and after 30 minutes of running. Cartilage thickness and signal intensity of surfaces of the patella, medial and lateral femoral and tibial condyles were measured. Results Cartilage thickness of the lateral condyle decreased at the dominant knee, while it increased at the medial tibial plateau. Signal intensity decreased at all locations, except the lateral patella in both knees. The most obvious decrease in signal intensity (10.6%) was at the medial tibial plateau from 949.8 to 849.0 of the dominant knee. Conclusion There was an increase in thickness measurements and decrease in signal intensity in medial tibial plateau of the dominant knee after 30 minutes of running. This outcome could be related to fluid outflow from the tissue. Greater reductions in the medial tibial plateau cartilage indicate greater load sharing by these areas of the joint during a 30-minute running.

  4. Determination of signal intensity affected by Gaussian noise

    International Nuclear Information System (INIS)

    Blostein, Jeronimo J.; Bennun, Leonardo

    1999-01-01

    A methodology based on maximum likelihood criteria, to identify and quantify an arbitrary signal affected by Gaussian noise is shown. To use this methodology it is necessary to know the position in the spectrum where the signal of interest should appear, and the shape of the signal when the background is null or unappreciable. (author)

  5. MRI investigation of normal fetal lung maturation using signal intensities on different imaging sequences

    International Nuclear Information System (INIS)

    Balassy, Csilla; Kasprian, Gregor; Weber, Michael; Hoermann, Marcus; Prayer, Daniela; Brugger, Peter C.; Csapo, Bence; Mittermayer, Christoph

    2007-01-01

    To purpose of this paper is to study the relation between normal lung maturation signal and changes in intensity ratios (SIR) and to determine which magnetic resonance imaging sequence provides the strongest correlation of normal lung SIs with gestational age. 126 normal singleton pregnancies (20-37 weeks) were examined with a 1.5 Tesla unit. Mean SIs for lungs, liver, and gastric fluid were assessed on six different sequences, and SIRs of lung/liver (LLSIR) and lung/gastric fluid (LGSIR) were correlated with gestational age for each sequence. To evaluate the feasibility of SIRs in the prediction of the state of the lung maturity, accuracy of the predicted SIRs (D*) was measured by calculating relative residuals (D*-D)/D for each sequence. LLSIRs showed significant changes in every sequence (p<0.05), while LGSIRs only on two sequences. Significant differences were shown for the mean of absolute residuals for both LLSIRs (p<0.001) and for LGSIRs (p=0.003). Relative residuals of LLSIRs were significantly smaller on T1-weighted sequence, whereas they were significantly higher for LGSIRs on FLAIR sequence. Fetal liver seems to be adequate reference for the investigation of lung maturation. T1-weighted sequence was the most accurate for the measurement of the lung SIs; thus, we propose to determine LLSIR on T1-weighted sequence when evaluating lung development. (orig.)

  6. MRI investigation of normal fetal lung maturation using signal intensities on different imaging sequences

    Energy Technology Data Exchange (ETDEWEB)

    Balassy, Csilla; Kasprian, Gregor; Weber, Michael; Hoermann, Marcus; Prayer, Daniela [Medical University of Vienna, Department of Radiology, Vienna (Austria); Brugger, Peter C. [Medical University of Vienna, Center of Anatomy and Cell Biology, Vienna (Austria); Csapo, Bence [Medical University of Vienna, Department of Obstetrics and Gyneocology, Vienna (Austria); Mittermayer, Christoph [Medical University of Vienna, Department of Pediatrics, Vienna (Austria)

    2007-03-15

    To purpose of this paper is to study the relation between normal lung maturation signal and changes in intensity ratios (SIR) and to determine which magnetic resonance imaging sequence provides the strongest correlation of normal lung SIs with gestational age. 126 normal singleton pregnancies (20-37 weeks) were examined with a 1.5 Tesla unit. Mean SIs for lungs, liver, and gastric fluid were assessed on six different sequences, and SIRs of lung/liver (LLSIR) and lung/gastric fluid (LGSIR) were correlated with gestational age for each sequence. To evaluate the feasibility of SIRs in the prediction of the state of the lung maturity, accuracy of the predicted SIRs (D*) was measured by calculating relative residuals (D*-D)/D for each sequence. LLSIRs showed significant changes in every sequence (p<0.05), while LGSIRs only on two sequences. Significant differences were shown for the mean of absolute residuals for both LLSIRs (p<0.001) and for LGSIRs (p=0.003). Relative residuals of LLSIRs were significantly smaller on T1-weighted sequence, whereas they were significantly higher for LGSIRs on FLAIR sequence. Fetal liver seems to be adequate reference for the investigation of lung maturation. T1-weighted sequence was the most accurate for the measurement of the lung SIs; thus, we propose to determine LLSIR on T1-weighted sequence when evaluating lung development. (orig.)

  7. Characterisation and correction of signal fluctuations in successive acquisitions of microarray images

    Directory of Open Access Journals (Sweden)

    François Nicolas

    2009-03-01

    Full Text Available Abstract Background There are many sources of variation in dual labelled microarray experiments, including data acquisition and image processing. The final interpretation of experiments strongly relies on the accuracy of the measurement of the signal intensity. For low intensity spots in particular, accurately estimating gene expression variations remains a challenge as signal measurement is, in this case, highly subject to fluctuations. Results To evaluate the fluctuations in the fluorescence intensities of spots, we used series of successive scans, at the same settings, of whole genome arrays. We measured the decrease in fluorescence and we evaluated the influence of different parameters (PMT gain, resolution and chemistry of the slide on the signal variability, at the level of the array as a whole and by intensity interval. Moreover, we assessed the effect of averaging scans on the fluctuations. We found that the extent of photo-bleaching was low and we established that 1 the fluorescence fluctuation is linked to the resolution e.g. it depends on the number of pixels in the spot 2 the fluorescence fluctuation increases as the scanner voltage increases and, moreover, is higher for the red as opposed to the green fluorescence which can introduce bias in the analysis 3 the signal variability is linked to the intensity level, it is higher for low intensities 4 the heterogeneity of the spots and the variability of the signal and the intensity ratios decrease when two or three scans are averaged. Conclusion Protocols consisting of two scans, one at low and one at high PMT gains, or multiple scans (ten scans can introduce bias or be difficult to implement. We found that averaging two, or at most three, acquisitions of microarrays scanned at moderate photomultiplier settings (PMT gain is sufficient to significantly improve the accuracy (quality of the data and particularly those for spots having low intensities and we propose this as a general

  8. Pulse-coupled neural nets: translation, rotation, scale, distortion, and intensity signal invariance for images.

    Science.gov (United States)

    Johnson, J L

    1994-09-10

    The linking-field neural network model of Eckhorn et al. [Neural Comput. 2, 293-307 (1990)] was introduced to explain the experimentally observed synchronous activity among neural assemblies in the cat cortex induced by feature-dependent visual activity. The model produces synchronous bursts of pulses from neurons with similar activity, effectively grouping them by phase and pulse frequency. It gives a basic new function: grouping by similarity. The synchronous bursts are obtained in the limit of strong linking strengths. The linking-field model in the limit of moderate-to-weak linking characterized by few if any multiple bursts is investigated. In this limit dynamic, locally periodic traveling waves exist whose time signal encodes the geometrical structure of a two-dimensional input image. The signal can be made insensitive to translation, scale, rotation, distortion, and intensity. The waves transmit information beyond the physical interconnect distance. The model is implemented in an optical hybrid demonstration system. Results of the simulations and the optical system are presented.

  9. Experimental investigation of saturation effect on pump-to-signal intensity modulation transfer in single-pump phase-insensitive fiber optic parametric amplifiers

    DEFF Research Database (Denmark)

    Cristofori, Valentina; Lali-Dastjerdi, Zohreh; Lund-Hansen, Toke

    2013-01-01

    We present an experimental characterization of how signal gain saturation affects the transfer of intensity modulation from the pump to the signal in single-pump, phase-insensitive fiber optic parametric amplifiers (FOPAs). In this work, we demonstrate experimentally for the first time, to our...... knowledge, how gain saturation of a FOPA reduces the noise contribution due to the transfer of pump power fluctuations to the signal. In a particular example, it is shown that the transferred noise is significantly reduced by a factor of 3, while the FOPA gain remains above 10 dB....

  10. A method for quantifying intervertebral disc signal intensity on T2-weighted imaging

    International Nuclear Information System (INIS)

    Nagashima, Masaki; Abe, Hitoshi; Amaya, Kenji; Matsumoto, Hideo; Yanaihara, Hisashi; Nishiwaki, Yuji; Toyama, Yoshiaki; Matsumoto, Morio

    2012-01-01

    Background Quantification of intervertebral disc degeneration based on intensity of the nucleus pulposus in magnetic resonance imaging (MRI) often uses the mean intensity of the region of interest (ROI) within the nucleus pulposus. However, the location and size of ROI have varied in different reports, and none of the reported methods can be considered fully objective. Purpose To develop a more objective method of establishing ROIs for quantitative evaluation of signal intensity in the nucleus pulposus using T2-weighted MRI. Material and Methods A 1.5-T scanner was used to obtain T2-weighted mid-sagittal images. A total of 288 intervertebral discs from 48 patients (25 men, 23 women) were analyzed. Mean age was 47.4 years (range, 17-69 years). All discs were classified into five grades according to Pfirrmann et al. Discs in grades I and II were defined as bright discs, and discs in grades IV and V were defined as dark discs. Eight candidate methods of ROI determination were devised. The method offering the highest degree of discrimination between bright and dark discs was investigated among these eight methods. Results The method with the greatest degree of discrimination was as follows. The quadrangle formed by anterior and posterior edges of the upper and lower end plates in contact with the intervertebral disc to be measured was defined as the intervertebral area. A shape similar to the intervertebral area but with one-quarter the area was drawn. The geometrical center of the shape was matched to the center of intensity, and this shape was then used as the ROI. Satisfactory validity and reproducibility were obtained using this method. Conclusion The present method offers adequate discrimination and could be useful for longitudinal tracking of intervertebral disc degeneration with sufficient reproducibility

  11. A method for quantifying intervertebral disc signal intensity on T2-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nagashima, Masaki [Dept. of Orthopaedic Surgery, Keio Univ. School of Medicine, Tokyo (Japan); Dept. of Orthopaedic Surgery, Kitasato Univ. Kitasato Inst. Hospital, Tokyo (Japan); Abe, Hitoshi [Dept. of Orthopaedic Surgery, Kitasato Univ. Kitasato Inst. Hospital, Tokyo (Japan)], E-mail: hit-abe@insti.kitasato-u.ac.jp; Amaya, Kenji [Graduate School of Information Science and Engineering, Tokyo Inst. of Technology, Tokyo (Japan); Matsumoto, Hideo [Inst. for Integrated Sports Medicine, Keio Univ. School of Medicine, Tokyo (Japan); Yanaihara, Hisashi [Dept. of Diagnostic Radiology, Kitasato Univ. Kitasato Inst. Hospital, Tokyo (Japan); Nishiwaki, Yuji [Dept. of Environmental and Occupational Health, Toho Univ. School of Medicine, Tokyo (Japan); Toyama, Yoshiaki; Matsumoto, Morio [Dept. of Orthopaedic Surgery, Keio Univ. School of Medicine, Tokyo (Japan)

    2012-11-15

    Background Quantification of intervertebral disc degeneration based on intensity of the nucleus pulposus in magnetic resonance imaging (MRI) often uses the mean intensity of the region of interest (ROI) within the nucleus pulposus. However, the location and size of ROI have varied in different reports, and none of the reported methods can be considered fully objective. Purpose To develop a more objective method of establishing ROIs for quantitative evaluation of signal intensity in the nucleus pulposus using T2-weighted MRI. Material and Methods A 1.5-T scanner was used to obtain T2-weighted mid-sagittal images. A total of 288 intervertebral discs from 48 patients (25 men, 23 women) were analyzed. Mean age was 47.4 years (range, 17-69 years). All discs were classified into five grades according to Pfirrmann et al. Discs in grades I and II were defined as bright discs, and discs in grades IV and V were defined as dark discs. Eight candidate methods of ROI determination were devised. The method offering the highest degree of discrimination between bright and dark discs was investigated among these eight methods. Results The method with the greatest degree of discrimination was as follows. The quadrangle formed by anterior and posterior edges of the upper and lower end plates in contact with the intervertebral disc to be measured was defined as the intervertebral area. A shape similar to the intervertebral area but with one-quarter the area was drawn. The geometrical center of the shape was matched to the center of intensity, and this shape was then used as the ROI. Satisfactory validity and reproducibility were obtained using this method. Conclusion The present method offers adequate discrimination and could be useful for longitudinal tracking of intervertebral disc degeneration with sufficient reproducibility.

  12. Low-intensity pulsed ultrasound is effective for progressive-stage lumbar spondylolysis with MRI high-signal change.

    Science.gov (United States)

    Arima, Hideyuki; Suzuki, Yoshiji; Togawa, Daisuke; Mihara, Yuki; Murata, Hideyuki; Matsuyama, Yukihiro

    2017-12-01

    This study aimed to investigate the treatment effects of low-intensity pulsed ultrasound (LIPUS) on progressive-stage spondylolysis. Spondylolysis is a stress fracture of the pars interarticularis. Based on the results of computed tomography, spondylolysis was classified into three categories: early, progressive, and terminal. Bone healing was prolonged or not obtained in progressive-stage spondylolysis. The progression of spondylolysis to nonunion has been associated with an increased incidence of spondylolisthesis. To prevent these clinical conditions, achieving bony healing of the spondylolysis site should be the goal of treatment. 15 consecutive pediatric patients with progressive-stage spondylolysis (defects) with MRI high-signal change were analyzed. Nine patients were treated conservative treatment including avoidance of any sport activity and the use of a brace during treatment (conventional). Six patients were treated using LIPUS everyday during treatment in addition to conservative treatment. Approximately every 1.5 months, bone healing was evaluated via CT. Cases that retained defects after 4.5 months were defined as nonunion. Two patients dropped out during the study period. A total of 13 patients (mean 14.6 ± 2.5 years) from the database met with 19 interarticularis defects. The bone union rate in LIPUS group was significantly higher than that in conventional group (66.7 vs. 10.0%, p = 0.020). The treatment period to bone union was 3.8 months and 2.7 ± 0.3 months in conventional and LIPUS groups. This study revealed that LIPUS treatment might be effective for bone union in patients with progressive-stage spondylolysis with MRI high-signal change. 4.

  13. Higher Education: Reputational Effects, Distorted Signaling and Propitious Selection

    Directory of Open Access Journals (Sweden)

    Elena V. Savitskaya

    2017-03-01

    Full Text Available In the paper the authors attempt to underpin the hypothesis that under certain conditions a propitious selection may take place on the higher education market. It is a phenomenon when brand universities automatically reproduce their positive reputation without improving the quality of teaching due to influx of talented entrants. The authors apply econometric modelling and regression analysis based on survey of first-year students from Moscow to demonstrate that graduates with high USE marks really prefer to choose among brand universities; moreover, they appreciate a possibility to obtain a prestigious diploma even more than that of acquiring a particular profession. However, entrants do not possess full information about the quality of teaching in a particular university. The analysis presented in the paper shows that university rankings do not contribute to overcoming of this information asymmetry, since they transmit distorted signals caused by the methodology of ranking. The rankings, first of all, accentuate academic activity of teachers rather than educational process and interaction with students. For this reason, higher schools often adopt such a strategy to meet the ranking criteria as much as possible; they also tend to improve namely these indicators disregarding the other to become a leader. As a result, brand universities may surpass ordinary universities not due to rendering educational services of higher quality but due to selection of best entrants and peer-effects. These factors allow them to have excellent graduates, thus maintain positive reputation in employers’ opinion and simultaneously raise the brand value by advancing in a ranking.

  14. Osseous lesions of the pelvis and long tubular bones containing both fat and fluid-like signal intensity: an analysis of 28 patients

    International Nuclear Information System (INIS)

    Chung, Christine B.; Murphey, Mark; Cho, Gina; Schweitzer, Mark; Hodler, Jeurg; Haghihi, Parvis; Resnick, Donald

    2005-01-01

    Purpose: The purpose of this study was to explore the nature of lesions in the pelvis and the long tubular bones that, with MR imaging, were found to contain both fat and fluid-like signal intensity and to correlate these findings with those of radiography, histologic analysis, and clinical and radiographic follow-up. Materials and methods: A retrospective review of the radiologic, clinical and histologic parameters of 28 patients with lesions in the pelvis and long tubular bones comprised of elements that demonstrated both fat and fluid signal intensity characteristics by MR imaging was performed. Several parameters were analyzed. Histologic analysis was available in 12 patients. Clinical and, or imaging follow-up was available in 13 patients. Results: Imaging and histologic findings suggested the presence of fat and fluid and fluid components in all lesions with which could be divided into distinct MR imaging patterns. Histologic analysis suggested the possibility of a shared pathogenesis among several different lesions. Conclusion: All lesions of the long tubular bones in our series revealing both fat and fluid-like signal intensities with MR imaging were nonaggressive on the basis of other imaging findings, follow-up assessment, histologic analysis, or combinations of the three. Histologic findings suggest a relationship among lipomas, fat necrosis and cystic infarct of bone

  15. High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted MR Images: Comparison between Gadobutrol and Linear Gadolinium-Based Contrast Agents.

    Science.gov (United States)

    Moser, F G; Watterson, C T; Weiss, S; Austin, M; Mirocha, J; Prasad, R; Wang, J

    2018-02-01

    In view of the recent observations that gadolinium deposits in brain tissue after intravenous injection, our aim of this study was to compare signal changes in the globus pallidus and dentate nucleus on unenhanced T1-weighted MR images in patients receiving serial doses of gadobutrol, a macrocyclic gadolinium-based contrast agent, with those seen in patients receiving linear gadolinium-based contrast agents. This was a retrospective analysis of on-site patients with brain tumors. Fifty-nine patients received only gadobutrol, and 60 patients received only linear gadolinium-based contrast agents. Linear gadolinium-based contrast agents included gadoversetamide, gadobenate dimeglumine, and gadodiamide. T1 signal intensity in the globus pallidus, dentate nucleus, and pons was measured on the precontrast portions of patients' first and seventh brain MRIs. Ratios of signal intensity comparing the globus pallidus with the pons (globus pallidus/pons) and dentate nucleus with the pons (dentate nucleus/pons) were calculated. Changes in the above signal intensity ratios were compared within the gadobutrol and linear agent groups, as well as between groups. The dentate nucleus/pons signal ratio increased in the linear gadolinium-based contrast agent group ( t = 4.215, P linear gadolinium-based contrast agent group ( t = 2.931, P linear gadolinium-based contrast agents. © 2018 by American Journal of Neuroradiology.

  16. Ca²⁺ signal contributing to the synthesis and emission of monoterpenes regulated by light intensity in Lilium 'siberia'.

    Science.gov (United States)

    Hu, Zenghui; Li, Tianjiao; Zheng, Jian; Yang, Kai; He, Xiangfeng; Leng, Pingsheng

    2015-06-01

    The floral scent is an important part of plant volatile compounds, and is influenced by environmental factors. The emission of monoterpenes of Lilium 'siberia' is regulated by light intensity, but the mechanism is large unknown. In this study, the expression of Li-mTPS, a monoterpene synthase gene in the tepals of Lilium 'siberia', and net Ca(2+) flux were investigated after exposure to different levels of light intensity (0, 100, 300, 600, 1000, and 1500 μmol m(-2) s(-1)). Moreover the effect of LaCl3 and ethylene glycol-bis-(2-aminoethylether)-N,N,N',N'-tetraacetic acid (EGTA) on the Li-mTPS expression, monoterpene emission, and net Ca(2+) flux were examined at 600 μmol m(-2) s(-1). The results showed that along with the enhancement of light intensity, the expression level of Li-mTPS increased gradually, and the net Ca(2+) influx was also enhanced showing a similar pattern. It was found that LaCl3 and EGTA effectively inhibited the increase in expression of Li-mTPS and the net Ca(2+) influx induced by light treatment. Moreover, the release amounts of monoterpenes decreased significantly after treatment with LaCl3 and EGTA. So it can be concluded that Ca(2+) signal contributed to the biosynthesis and emission of monoterpenes regulated by light intensity in Lilium 'siberia' tepals. The increased light intensity firstly triggered the Ca(2+) influx to cytoplasm, and then the gene expression of monoterpene synthases downstream was activated to regulate the biosynthesis and emission of monoterpenes. But in the signaling pathway other mechanisms were thought to be involved in the emission of monoterpenes regulated by light intensity, which need to be investigated in future research. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. Change in signal intensity on MRI of fat in the head of markedly emaciated patients

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, K.; Ishikawa, K.; Sakai, K. [Niigata Univ. (Japan). Dept. of Radiology; Ito, J.; Tokiguchi, S. [Dept. of Radiology, Niigata Univ. (Japan)

    2001-02-01

    The amount of fat in various parts of the body decreases in emaciated patients, but responds differently to disease processes. The order of disappearance of fat in various parts of the head has rarely been studied with MRI. We imaged ten patients with anorexia nervosa and one cachectic patient with a psychiatric disorder with a 1.5 T imager. Signal intensities of bone marrow of the skull, subcutaneous tissue, and orbits were assessed on T1- and T2-weighted images, and correlated with the body mass index (BMI) and haemoglobin concentration (Hb). On T1-weighted images, five patients (BMI 15.6-17.8 kg/m{sup 2}, mean 16.6 kg/m{sup 2}; Hb 10.1-14.2 g/dl, mean 13.8 g/dl) showed the normal pattern of fat. One (BMI 13.6 kg/m{sup 2}, Hb 10.4 g/dl) lost the high signal of bone marrow, but high signal of subcutaneous tissue and the orbits was preserved. High signal from bone marrow and subcutaneous tissue disappeared in three patients (BMI 11.5-13.5 kg/m{sup 2}, mean 12.5 kg/m{sup 2}; Hb 7.9-9.7 g/dl, mean 8.7 g/dl), but orbital high signal was preserved. The remaining two patients (BMI 9.3 and 13.5 kg/m{sup 2}, mean 11.5 kg/m{sup 2}; Hb 7.6 and 8.9 g/dl, mean 8.3 g/dl) showed complete loss of high signal from fat in the head. The order of disappearance of fat (bone marrow, subcutaneous fat, then orbits) correlated with both BMI and Hb. Atrophy of bone marrow was demonstrated on T2-weighted images in five patients with BMI 13.5 kg/m{sup 2} or less, and Hb 9.7 g/dl or less. (orig.)

  18. Change in signal intensity on MRI of fat in the head of markedly emaciated patients

    International Nuclear Information System (INIS)

    Okamoto, K.; Ishikawa, K.; Sakai, K.

    2001-01-01

    The amount of fat in various parts of the body decreases in emaciated patients, but responds differently to disease processes. The order of disappearance of fat in various parts of the head has rarely been studied with MRI. We imaged ten patients with anorexia nervosa and one cachectic patient with a psychiatric disorder with a 1.5 T imager. Signal intensities of bone marrow of the skull, subcutaneous tissue, and orbits were assessed on T1- and T2-weighted images, and correlated with the body mass index (BMI) and haemoglobin concentration (Hb). On T1-weighted images, five patients (BMI 15.6-17.8 kg/m 2 , mean 16.6 kg/m 2 ; Hb 10.1-14.2 g/dl, mean 13.8 g/dl) showed the normal pattern of fat. One (BMI 13.6 kg/m 2 , Hb 10.4 g/dl) lost the high signal of bone marrow, but high signal of subcutaneous tissue and the orbits was preserved. High signal from bone marrow and subcutaneous tissue disappeared in three patients (BMI 11.5-13.5 kg/m 2 , mean 12.5 kg/m 2 ; Hb 7.9-9.7 g/dl, mean 8.7 g/dl), but orbital high signal was preserved. The remaining two patients (BMI 9.3 and 13.5 kg/m 2 , mean 11.5 kg/m 2 ; Hb 7.6 and 8.9 g/dl, mean 8.3 g/dl) showed complete loss of high signal from fat in the head. The order of disappearance of fat (bone marrow, subcutaneous fat, then orbits) correlated with both BMI and Hb. Atrophy of bone marrow was demonstrated on T2-weighted images in five patients with BMI 13.5 kg/m 2 or less, and Hb 9.7 g/dl or less. (orig.)

  19. Direct measurement of the signal intensity of diffusion-weighted magnetic resonance imaging for preoperative grading and treatment guidance for brain gliomas

    Directory of Open Access Journals (Sweden)

    Chih-Chun Wu

    2012-11-01

    Conclusion: The proposed method – direct measuring of tumor signal intensity of DWI on PACS monitors – is feasible for grading gliomas in clinical neuro-oncology imaging services and has a high level of reliability and reproducibility.

  20. Intense diagnostic neutral beam development for ITER

    International Nuclear Information System (INIS)

    Rej, D.J.; Henins, I.; Fonck, R.J.; Kim, Y.J.

    1992-01-01

    For the next-generation, burning tokamak plasmas such as ITER, diagnostic neutral beams and beam spectroscopy will continue to be used to determine a variety of plasma parameters such as ion temperature, rotation, fluctuations, impurity content, current density profile, and confined alpha particle density and energy distribution. Present-day low-current, long-pulse beam technology will be unable to provide the required signal intensities because of higher beam attenuation and background bremsstrahlung radiation in these larger, higher-density plasmas. To address this problem, we are developing a short-pulse, intense diagnostic neutral beam. Protons or deuterons are accelerated using magnetic-insulated ion-diode technology, and neutralized in a transient gas cell. A prototype 25-kA, 100-kV, 1-μs accelerator is under construction at Los Alamos. Initial experiments will focus on ITER-related issues of beam energy distribution, current density, pulse length, divergence, propagation, impurity content, reproducibility, and maintenance

  1. Photon statistics of pulse-pumped four-wave mixing in fiber with weak signal injection

    Science.gov (United States)

    Nan-Nan, Liu; Yu-Hong, Liu; Jia-Min, Li; Xiao-Ying, Li

    2016-07-01

    We study the photon statistics of pulse-pumped four-wave mixing in fibers with weak coherent signal injection by measuring the intensity correlation functions of individual signal and idler fields. The experimental results show that the intensity correlation function of individual signal (idler) field decreases with the intensity of signal injection. After applying narrow band filter in signal (idler) band, the value of decreases from 1.9 ± 0.02 (1.9 ± 0.02) to 1.03 ± 0.02 (1.05 ± 0.02) when the intensity of signal injection varies from 0 to 120 photons/pulse. The results indicate that the photon statistics changes from Bose-Einstein distribution to Poisson distribution. We calculate the intensity correlation functions by using the multi-mode theory of four-wave mixing in fibers. The theoretical curves well fit the experimental results. Our investigation will be useful for mitigating the crosstalk between quantum and classical channels in a dense wavelength division multiplexing network. Project supported by the National Natural Science Foundation of China (Grant No. 11527808), the State Key Development Program for Basic Research of China (Grant No. 2014CB340103), the Specialized Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20120032110055), the Natural Science Foundation of Tianjin, China (Grant No. 14JCQNJC02300), the Program for Changjiang Scholars and Innovative Research Team in University, China, and the Program of Introducing Talents of Discipline to Universities, China (Grant No. B07014).

  2. Non-gated vessel wall imaging of the internal carotid artery using radial scanning and fast spin echo sequence. Evaluation of vessel signal intensity by flow rate at 3.0 tesla

    International Nuclear Information System (INIS)

    Nakamura, Manami; Makabe, Takeshi; Ichikawa, Masaki; Hatakeyama, Ryohei; Sugimori, Hiroyuki; Sakata, Motomichi

    2013-01-01

    Vessel wall imaging using radial scanning does not use a blood flow suppression pulse with gated acquisition. It has been proposed that there may not be a flow void effect if the flow rate is slow; however, this has yet to be empirically tested. To clarify the relationship between the signal intensity of the vessel lumen and the blood flow rate in a flow phantom, we investigated the usefulness of vessel wall imaging at 3.0 tesla (T). We measured the signal intensity while changing the flow rate in the flow phantom. Radial scanning at 1.5 T showed sufficient flow voids at above medium flow rates. There was no significant difference in lumen signal intensity at the carotid artery flow rate. The signal intensity of the vessel lumen decreased sufficiently using the radial scan method at 3.0 T. We thus obtained sufficient flow void effects at the carotid artery flow rate. We conclude this technique to be useful for evaluating plaque if high contrast can be maintained for fixed tissue (such as plaque) and the vessel lumen. (author)

  3. Risk-associated health disorders occuring in junior schoolchildren who attend schools with higher stress and intensity of educational process

    Directory of Open Access Journals (Sweden)

    N.V. Zaitseva

    2017-03-01

    Full Text Available We performed comparative sanitary-hygienic assessment of regime, stress and intensity of educational process in different educational establishments, a comprehensive secondary school and an innovative educational establishment - lyceum. We detected that studying regime tended to be tight, classes were longer and more intense than in an ordinary school, and educational process involved considerable intellectual, sensory and emotional loads for children; such loads reached "1st category intense" level. Schoolchildren attending lyceums are also busy with additional educational programs and it significantly increases length of total educational load on them. By the end of a school year 20% of lyceum pupils suffer from sympathoadrenal system overstress and it doesn't only determine emotional tonus level in children but also leads to disorders in concentration and decision-making speed, lower reading speed and articulation, slower motor reactions. 15% of lyceum pupils have higher activity of autonomous nervous system and lower adaptation of cardiovascular system to psycho emotional and physical loads. Lyceum pupils also run 2.5 times higher risk of chronic nervous system diseases evolvement than school children attending ordinary schools. Autonomous nervous system disorders, posture disorders and nutrition disorders are predominant nosologic pathology forms in lyceum pupils as they occur in them 1.6-2.9 times more frequent than in schoolchildren of the same age who attend an ordinary comprehensive school. We detected direct correlation between higher intellectual and emotional components of educational process, and total educational intensity as well, and frequency of autonomous system disorders and musculoskeletal system diseases in pupils.

  4. Intravenous injection of gadobutrol in an epidemiological study group did not lead to a difference in relative signal intensities of certain brain structures after 5 years

    Energy Technology Data Exchange (ETDEWEB)

    Kromrey, Marie-Luise; Liedtke, Kim Rouven; Langner, Soenke; Kirsch, Michael; Kuehn, Jens-Peter [University Medicine Greifswald, Institute of Diagnostic Radiology and Neuroradiology, Greifswald (Germany); Ittermann, Till [University Medicine Greifswald, Institute for Community Medicine, Greifswald (Germany); Weitschies, Werner [University Greifswald, Institute of Biopharmacy and Pharmaceutical Technology, Greifswald (Germany)

    2017-02-15

    To investigate if application of macrocyclic gadolinium-based contrast agents in volunteers is associated with neuronal deposition detected by magnetic resonance imaging in a 5-year longitudinal survey. Three hundred eighty-seven volunteers who participated in a population-based study were enrolled. Subjects underwent plain T1-weighted brain MRI at baseline and 5 years later with identical sequence parameters. At baseline, 271 participants additionally received intravenous injection of the macrocyclic contrast agent gadobutrol (1.5 mmol/kg). A control group including 116 subjects received no contrast agent. Relative signal intensities of thalamus, pallidum, pons and dentate nucleus were compared at baseline and follow-up. No difference in relative signal intensities was observed between contrast group (thalamus, p = 0.865; pallidum, p = 0.263; pons, p = 0.533; dentate nucleus, p = 0.396) and control group (thalamus, p = 0.683; pallidum; p = 0.970; pons, p = 0.773; dentate nucleus, p = 0.232) at both times. Comparison between both groups revealed no significant differences in relative signal intensities (thalamus, p = 0.413; pallidum, p = 0.653; pons, p = 0.460; dentate nucleus, p = 0.751). The study showed no significant change in globus pallidus-to-thalamus or dentate nucleus-to-pons ratios. Five years after administration of a 1.5-fold dose gadobutrol to normal subjects, signal intensity of thalamus, pallidum, pons and dentate nucleus did not differ from participants who had not received gadobutrol. (orig.)

  5. Intranodular signal intensity analysis of hypovascular high-risk borderline lesions of HCC that illustrate multi-step hepatocarcinogenesis within the nodule on Gd–EOB–DTPA-enhanced MRI

    International Nuclear Information System (INIS)

    Kobayashi, Satoshi; Matsui, Osamu; Gabata, Toshifumi; Koda, Wataru; Minami, Tetsuya; Ryu, Yasuji; Kozaka, Kazuto; Kitao, Azusa

    2012-01-01

    Objectives: To analyze intranodular signal intensity pattern of hypovascular high-risk borderline lesions of HCC that illustrate multi-step hepatocarcinogenesis within the nodule on Gd–EOB–DTPA-enhanced MRI. Methods: A total of 73 nodules showing hypervascular foci in hypovascular high-risk borderline lesions identified by angiography-assisted CT were included in this study. The intranodular signal intensities of both the hypervascular foci and the hypovascular high-risk borderline lesions were evaluated on hepatobiliary-phase EOB-enhanced MRI obtained 20 min after intravenous injection of contrast media. Results: Among 59 hypervascular foci within hypointense hypovascular high-risk borderline lesions, 6 showed more hypointensity, 32 isointensity, and 21 hyperintensity compared to the surrounding hypointense, hypovascular portion of the nodules. Among 14 hypervascular foci within isointense hypovascular high-risk borderline lesions, 5 showed isointensity, and 9 hypointensity compared to the surrounding isointense hypovascular high-risk borderline lesions. No hypervascular foci showed hyperintensity compared to the surrounding isointense hypovascular high-risk borderline lesions. Conclusions: In most of the hypovascular high-risk borderline lesions containing hypervascular foci within the nodule, the signal intensity was decreased in hypervascular foci as compared with hypovascular high-risk borderline lesions and the surrounding background liver parenchyma. This supports the concept of signal intensity decrease during the dedifferentiation process in multistep hepatocarcinogenesis. However, around 30% of the nodules did not follow this rule, and hypervascular foci showed hyperintensity relative to the hypovascular high-risk borderline lesions.

  6. Exercise-intensity dependent alterations in plasma redox status do not reflect skeletal muscle redox-sensitive protein signaling.

    Science.gov (United States)

    Parker, Lewan; Trewin, Adam; Levinger, Itamar; Shaw, Christopher S; Stepto, Nigel K

    2018-04-01

    Redox homeostasis and redox-sensitive protein signaling play a role in exercise-induced adaptation. The effects of sprint-interval exercise (SIE), high-intensity interval exercise (HIIE) and continuous moderate-intensity exercise (CMIE), on post-exercise plasma redox status are unclear. Furthermore, whether post-exercise plasma redox status reflects skeletal muscle redox-sensitive protein signaling is unknown. In a randomized crossover design, eight healthy adults performed a cycling session of HIIE (5×4min at 75% W max ), SIE (4×30s Wingate's), and CMIE work-matched to HIIE (30min at 50% of W max ). Plasma hydrogen peroxide (H 2 O 2 ), thiobarbituric acid reactive substances (TBARS), superoxide dismutase (SOD) activity, and catalase activity were measured immediately post, 1h, 2h and 3h post-exercise. Plasma redox status biomarkers were correlated with phosphorylation of skeletal muscle p38-MAPK, JNK, NF-κB, and IκBα protein content immediately and 3h post-exercise. Plasma catalase activity was greater with SIE (56.6±3.8Uml -1 ) compared to CMIE (42.7±3.2, pexercise plasma TBARS and SOD activity significantly (pexercise protocol. A significant positive correlation was detected between plasma catalase activity and skeletal muscle p38-MAPK phosphorylation 3h post-exercise (r=0.40, p=0.04). No other correlations were detected (all p>0.05). Low-volume SIE elicited greater post-exercise plasma catalase activity compared to HIIE and CMIE, and greater H 2 O 2 compared to CMIE. Plasma redox status did not, however, adequately reflect skeletal muscle redox-sensitive protein signaling. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  7. The latest from the LHC : Training for higher intensities

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Three weeks of intense machine development were brought to a satisfactory conclusion on the night of 21 September with the final validation of the machine protection systems for operation with bunch trains. The machine is now ready to accept more and more trains of bunches.   On Wednesday 22 September, the first physics fill was made using bunch trains, with 3 trains of 8 bunches per beam, providing 16 pairs of colliding bunches per experiment. This fill was used to restart operation for physics both for the machine and for the experiments. On Thursday, the number of bunches was increased to 56 per beam, providing 47 colliding pairs at Points 1, 5 and 8, and a smaller number at Point 2 to meet the requirements of ALICE. This is roughly the same intensity that we had in the machine in August. The first fill made under these conditions, fill 1366, brought an unexpected bonus. Bunches of nominal intensity were injected into the LHC with a smaller than usual transverse size, which was expected to cau...

  8. The effect of auditory memory load on intensity resolution in individuals with Parkinson's disease

    Science.gov (United States)

    Richardson, Kelly C.

    Purpose: The purpose of the current study was to investigate the effect of auditory memory load on intensity resolution in individuals with Parkinson's disease (PD) as compared to two groups of listeners without PD. Methods: Nineteen individuals with Parkinson's disease, ten healthy age- and hearing-matched adults, and ten healthy young adults were studied. All listeners participated in two intensity discrimination tasks differing in auditory memory load; a lower memory load, 4IAX task and a higher memory load, ABX task. Intensity discrimination performance was assessed using a bias-free measurement of signal detectability known as d' (d-prime). Listeners further participated in a continuous loudness scaling task where they were instructed to rate the loudness level of each signal intensity using a computerized 150mm visual analogue scale. Results: Group discrimination functions indicated significantly lower intensity discrimination sensitivity (d') across tasks for the individuals with PD, as compared to the older and younger controls. No significant effect of aging on intensity discrimination was observed for either task. All three listeners groups demonstrated significantly lower intensity discrimination sensitivity for the higher auditory memory load, ABX task, compared to the lower auditory memory load, 4IAX task. Furthermore, a significant effect of aging was identified for the loudness scaling condition. The younger controls were found to rate most stimuli along the continuum as significantly louder than the older controls and the individuals with PD. Conclusions: The persons with PD showed evidence of impaired auditory perception for intensity information, as compared to the older and younger controls. The significant effect of aging on loudness perception may indicate peripheral and/or central auditory involvement.

  9. Interpreting intensities in vibrational sum frequency generation (SFG) spectroscopy: CO adsorption on Pd surfaces

    Science.gov (United States)

    Morkel, M.; Unterhalt, H.; Klüner, T.; Rupprechter, G.; Freund, H.-J.

    2005-07-01

    The lineshape and intensity of SFG signals of CO adsorbed on supported Pd nanoparticles and Pd(1 1 1) are analyzed. For CO/Pd(1 1 1) nearly symmetric lorentzian lineshapes were observed. Applying two different visible wavelengths for excitation, asymmetric lineshapes observed for the CO/Pd/Al 2O 3/NiAl(1 1 0) system are explained by a lower resonant and a higher non-resonant SFG signal and a change in the phase between resonant and non-resonant signals, most likely originating from an interband transition in the NiAl substrate. The relative intensity of different CO species (hollow, bridge, on-top) was modeled by DFT calculations of IR transition moments and Raman activities. While the (experimental) sensitivity of SFG towards different CO species strongly varies, the calculated IR and Raman activities are rather similar. The inability to exactly reproduce experimental SFG intensities suggests a strong coverage dependence of Raman activities or that non-linear effects occur that can currently not be properly accounted for.

  10. Studies on the clinical significance of pallidal high intensity of T1-weighted MR imaging in patients with liver cirrhosis

    International Nuclear Information System (INIS)

    Morino, Koutaro

    1997-01-01

    We investigated the clinical significances of signals in cirrhotic patients with special relation to subclinical hepatic encephalopathy. MRI was carried out in 30 patients with liver cirrhosis in the abscence of hepatic encephalopathy greater than grade II, and in 20 healthy subjects. Signal intensity of the globus pallidus was standardized to GP index. GP index=100 x (signal intensity of the globus pallidus - signal intensity of the putamen)/(signal intensity of the globus pallidus + signal intensity of the putamen). Normal value of GP index obtained in healthy subjects was -0.66∼4.70. Twenty seven of 30 cirrhotic patients showed GP index higher than the normal range. GP index correlated significantly with the blood manganese concentration. This observation suggested that the pallidal high intensity signals were brought about by the deposition of Mn in the globus pallidus. GP index correlated significantly with the central conduction time (CCT) measured by somatosensory evoked potentials. GP index and CCT may reflect the similar pathophysiological changes of the brain in patients with liver cirrhosis. Multivariate analysis revealed that GP index was explained well by the presence of portal systemic shunts and by preceding histories of hepatic encephalopathy but not by the present grade of the liver parenchymal damage. For the earlier diagnosis of subclinical hepatic encephalopathy, GP index showed an excellent parameter similar to those of somatosensory evoked potentials and psychometric tests. GP index is favorable than electrophysiological methods in terms of its non-invasiveness to the patients and simplicity of the examination technique. (K.H.)

  11. Higher order harmonic generation in the intense laser pulse

    International Nuclear Information System (INIS)

    Parvizi, R.; Bahrampour, A.; Karimi, M.

    2006-01-01

    The high intensity pulse of laser field ionizes the atoms and electrons are going to the continuum states of atoms. electrons absorb energy from the strong laser field. The back ground electromagnetic field causes to come back the electrons to ground states of atoms and the absorbed energy is emitted as a high order odd harmonics of incident light. The intensity of emitted harmonics depends on the material atoms and the laser pulse shape. I this paper the effects of step pulse duration on the high order harmonic radiated by the Argon, Helium, and Hydrogen atoms are reported.

  12. Preoperative diagnosis of breast diseases by dynamic MR mammography. Cut off point establishment for signal intensity ratio

    International Nuclear Information System (INIS)

    Tsuchiya, Juji; Nagata, Takayasu; Kawagoe, Hajime; Tachibana, Susumu; Kajima, Toshihiko; Hoshino, Mutsuo; Uno, Takashi; Shimokawa, Kuniyasu.

    1997-01-01

    We have revealed that a dynamic study of the breast using MR imaging technique can estimate objectively benign-malignant differentiative diagnosis. Subjects were 41 cases of breast lesion, including 13 cases of breast cancer, 21 cases of mastopathy, six cases of fibroadenoma and one case of intraductal papillomatosis and the results of them were investigated in comparison with histopathological diagnosis. As so the method, we drew up time-signal intensity ratio curve plotting signal intensity ratio at each 30 second of dynamic MR mammography after Gd-DTPA administration. We found a especially high significant difference between cancer and mastopathy, within 90 second after Gd-DTPA administration (p=0.0000). Still more, we established cut off point concerning with establishment of 95% confidence interval, that is, at 30 second after Gd-DTPA administration of point equivalent 1.53 at 60 second equivalent 2.00, at 90 second equivalent 2.47, and about this estimating maneuver using the cut off point we named Dynamic ratio method. We can estimate preoperatively not only benign-malignant differentiative diagnosis with breast tumor, but also neighboring infiltration and lymph node metastasis of breast cancer using this Dynamic ratio method. Over again, Dynamic ratio method provides fine information to preoperative decision of resecting region for breast conserving surgery. The efficiency of this method is sensitivity=92.3%, specificity=89.3% and positive predictive value=80.0%. (author)

  13. Preoperative diagnosis of breast diseases by dynamic MR mammography. Cut off point establishment for signal intensity ratio

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Juji; Nagata, Takayasu; Kawagoe, Hajime; Tachibana, Susumu; Kajima, Toshihiko; Hoshino, Mutsuo [Ibi General Hospital, Gifu (Japan); Uno, Takashi; Shimokawa, Kuniyasu

    1997-12-01

    We have revealed that a dynamic study of the breast using MR imaging technique can estimate objectively benign-malignant differentiative diagnosis. Subjects were 41 cases of breast lesion, including 13 cases of breast cancer, 21 cases of mastopathy, six cases of fibroadenoma and one case of intraductal papillomatosis and the results of them were investigated in comparison with histopathological diagnosis. As so the method, we drew up time-signal intensity ratio curve plotting signal intensity ratio at each 30 second of dynamic MR mammography after Gd-DTPA administration. We found a especially high significant difference between cancer and mastopathy, within 90 second after Gd-DTPA administration (p=0.0000). Still more, we established cut off point concerning with establishment of 95% confidence interval, that is, at 30 second after Gd-DTPA administration of point equivalent 1.53 at 60 second equivalent 2.00, at 90 second equivalent 2.47, and about this estimating maneuver using the cut off point we named Dynamic ratio method. We can estimate preoperatively not only benign-malignant differentiative diagnosis with breast tumor, but also neighboring infiltration and lymph node metastasis of breast cancer using this Dynamic ratio method. Over again, Dynamic ratio method provides fine information to preoperative decision of resecting region for breast conserving surgery. The efficiency of this method is sensitivity=92.3%, specificity=89.3% and positive predictive value=80.0%. (author)

  14. Brain MRI findings of welders : high signal intensity in T1WI secondary to manganese exposure

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K. W.; Lim, M. A.; Shon, M. Y.; Lee, S. H.; Ha, D. G.; Kwon, K. R.; Kim, S. S.; Hong, Y. S.; Lee, Y. H. [Sunlin Presbyterian Hospital, Pohang (Korea, Republic of); Cheong, H. K. [Dongguk University, Seoul (Korea, Republic of)

    1998-03-01

    To evaluate the clinical and brain MRI findings of welders and to determine the utility of MRI in the assessment of occupational manganese exposure. All welders complained of fatigue, headache, anorexia, and decreased libido. The palmomental reflex was positive in five (28%), Myerson`s sign in four (22%), and intention tremor in three (17%). Mean blood Mn was 5.18 (range, 1.77-9.34) {mu}g/dl, mean urine Mn was 5.84 (range, 1.07 -22) {mu}g/l, serum Fe was elevated in one welder, and serum Cd in two. T1WI of brain MRI revealed high signal intensities in the globus pallidus, the putamen, the substantia nigra, the tectum, the caudate nucleus, the subthalamic nucleus, the hypothalamus and the pituitary gland. These intensities correlated closely with blood Mn levels, suggesting their potential role in estimating the accumulation of Mn in the brain. (author). 25 refs., 2 tabs., 5 figs.

  15. Studies on the clinical significance of pallidal high intensity of T{sub 1}-weighted MR imaging in patients with liver cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Morino, Koutaro [Gifu Univ. (Japan). School of Medicine

    1997-03-01

    We investigated the clinical significances of signals in cirrhotic patients with special relation to subclinical hepatic encephalopathy. MRI was carried out in 30 patients with liver cirrhosis in the abscence of hepatic encephalopathy greater than grade II, and in 20 healthy subjects. Signal intensity of the globus pallidus was standardized to GP index. GP index=100 x (signal intensity of the globus pallidus - signal intensity of the putamen)/(signal intensity of the globus pallidus + signal intensity of the putamen). Normal value of GP index obtained in healthy subjects was -0.66{approx}4.70. Twenty seven of 30 cirrhotic patients showed GP index higher than the normal range. GP index correlated significantly with the blood manganese concentration. This observation suggested that the pallidal high intensity signals were brought about by the deposition of Mn in the globus pallidus. GP index correlated significantly with the central conduction time (CCT) measured by somatosensory evoked potentials. GP index and CCT may reflect the similar pathophysiological changes of the brain in patients with liver cirrhosis. Multivariate analysis revealed that GP index was explained well by the presence of portal systemic shunts and by preceding histories of hepatic encephalopathy but not by the present grade of the liver parenchymal damage. For the earlier diagnosis of subclinical hepatic encephalopathy, GP index showed an excellent parameter similar to those of somatosensory evoked potentials and psychometric tests. GP index is favorable than electrophysiological methods in terms of its non-invasiveness to the patients and simplicity of the examination technique. (K.H.)

  16. Investigation of EPR signals on tooth enamel

    Energy Technology Data Exchange (ETDEWEB)

    Pavlenko, A; Mironova-Ulmane, N; Polakov, M; Riekstina, D [Institute of Solid State Physics, University of Latvia, Riga (Latvia)

    2007-12-15

    Calcified tissues are involved in continues metabolic process in human organism exchanging a number of chemical elements with environment. The rate of biochemical reactions is tissue dependent and the slowest one at the tooth enamel, the most mineralized tissue of human organism. The long time stability and unique chemical composition make tooth enamel suitable for number of application. The assessment of individual radiation dose by Electron Paramagnetic Resonance (EPR) and evaluations of elemental composition by Instrumentation Neutron Activation Analysis (INAA) are the well known procedures where properties of tooth enamel intensively used. The current work is focused on investigation of EPR signals and determination of chemical composition on several teeth samples having different origin. The EPR spectra and INAA element content of milk tooth, caries tooth, and paradantose tooth have been compared to each other. The results showed that the intensity of EPR signal is much higher for the caries tooth than the for paradantose tooth that is in agreement with depleted Ca content.

  17. Photon-photon scattering at the high-intensity frontier

    Science.gov (United States)

    Gies, Holger; Karbstein, Felix; Kohlfürst, Christian; Seegert, Nico

    2018-04-01

    The tremendous progress in high-intensity laser technology and the establishment of dedicated high-field laboratories in recent years have paved the way towards a first observation of quantum vacuum nonlinearities at the high-intensity frontier. We advocate a particularly prospective scenario, where three synchronized high-intensity laser pulses are brought into collision, giving rise to signal photons, whose frequency and propagation direction differ from the driving laser pulses, thus providing various means to achieve an excellent signal to background separation. Based on the theoretical concept of vacuum emission, we employ an efficient numerical algorithm which allows us to model the collision of focused high-intensity laser pulses in unprecedented detail. We provide accurate predictions for the numbers of signal photons accessible in experiment. Our study is the first to predict the precise angular spread of the signal photons, and paves the way for a first verification of quantum vacuum nonlinearity in a well-controlled laboratory experiment at one of the many high-intensity laser facilities currently coming online.

  18. Concept for phase-to-intensity conversion in SOAs by facet reflections

    DEFF Research Database (Denmark)

    Blaaberg, Søren; Mørk, Jesper

    2010-01-01

    All-optical conversion from phase-modulated signals to intensity-modulated signals is theoretically demonstrated in semiconductor optical amplifiers (SOAs). Large-signal and small-signal calculations show significant conversion responses appearing as a result of even minute reflections at the end...... mirrors of the SOA. It is discussed how reflected phase-modulated signals can lead to interference resulting in intensity fluctuations that are amplified by the gain in a SOA. The effect can be utilized for deliberate conversion between optical modulation formats.......All-optical conversion from phase-modulated signals to intensity-modulated signals is theoretically demonstrated in semiconductor optical amplifiers (SOAs). Large-signal and small-signal calculations show significant conversion responses appearing as a result of even minute reflections at the end...

  19. Intravenous injection of gadobutrol in an epidemiological study group did not lead to a difference in relative signal intensities of certain brain structures after 5 years.

    Science.gov (United States)

    Kromrey, Marie-Luise; Liedtke, Kim Rouven; Ittermann, Till; Langner, Sönke; Kirsch, Michael; Weitschies, Werner; Kühn, Jens-Peter

    2017-02-01

    To investigate if application of macrocyclic gadolinium-based contrast agents in volunteers is associated with neuronal deposition detected by magnetic resonance imaging in a 5-year longitudinal survey. Three hundred eighty-seven volunteers who participated in a population-based study were enrolled. Subjects underwent plain T1-weighted brain MRI at baseline and 5 years later with identical sequence parameters. At baseline, 271 participants additionally received intravenous injection of the macrocyclic contrast agent gadobutrol (0.15 mmol/kg). A control group including 116 subjects received no contrast agent. Relative signal intensities of thalamus, pallidum, pons and dentate nucleus were compared at baseline and follow-up. No difference in relative signal intensities was observed between contrast group (thalamus, p = 0.865; pallidum, p = 0.263; pons, p = 0.533; dentate nucleus, p = 0.396) and control group (thalamus, p = 0.683; pallidum; p = 0.970; pons, p = 0.773; dentate nucleus, p = 0.232) at both times. Comparison between both groups revealed no significant differences in relative signal intensities (thalamus, p = 0.413; pallidum, p = 0.653; pons, p = 0.460; dentate nucleus, p = 0.751). The study showed no significant change in globus pallidus-to-thalamus or dentate nucleus-to-pons ratios. Five years after administration of a 1.5-fold dose gadobutrol to normal subjects, signal intensity of thalamus, pallidum, pons and dentate nucleus did not differ from participants who had not received gadobutrol. • Gadobutrol does not lead to neuronal signal alterations after 5 years. • Neuronal deposition of macrocyclic contrast agent could not be confirmed. • Macrocyclic contrast agents in a proven dosage are safe.

  20. CBL-CIPK network for calcium signaling in higher plants

    Science.gov (United States)

    Luan, Sheng

    Plants sense their environment by signaling mechanisms involving calcium. Calcium signals are encoded by a complex set of parameters and decoded by a large number of proteins including the more recently discovered CBL-CIPK network. The calcium-binding CBL proteins specifi-cally interact with a family of protein kinases CIPKs and regulate the activity and subcellular localization of these kinases, leading to the modification of kinase substrates. This represents a paradigm shift as compared to a calcium signaling mechanism from yeast and animals. One example of CBL-CIPK signaling pathways is the low-potassium response of Arabidopsis roots. When grown in low-K medium, plants develop stronger K-uptake capacity adapting to the low-K condition. Recent studies show that the increased K-uptake is caused by activation of a specific K-channel by the CBL-CIPK network. A working model for this regulatory pathway will be discussed in the context of calcium coding and decoding processes.

  1. MR-imaging of finger osteoarthritis: Morphology and cartrilage signal intensity before and after treatment with ademetionin; Magnetresonanztomographie der Fingerpolyarthrose: Morphologie und Knorpelsignalverhalten unter Ademetonintherapie

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, H. [Radiologische Klinik, Abt. fuer Roentgendiagnostik und Nuklearmedizin, Univ.-Klinikum Steglitz, FU Berlin (Germany); Stahl, H. [Radiologische Klinik, Univ.-Klinikum Rudolf-Virchow, FU Berlin (Germany); Sieper, J. [Medizinische Klinik und Poliklinik, Univ.-Klinikum Steglitz, FU Berlin (Germany); Wolf, K.J. [Radiologische Klinik, Abt. fuer Roentgendiagnostik und Nuklearmedizin, Univ.-Klinikum Steglitz, FU Berlin (Germany)

    1995-01-01

    This report deals with a prospective study of 21 patients with finger osteoarthritis treated over a period of three months with either Ademetionin (therapy group: 14/21) or without (control group: 7/21). MR-Imaging was carried out before and after treatment using spin-echo and 3D-Flash sequences. Morphological parameters and signal intensity changes of the hyaline cartilage were evaluated. The increase of the cartilage signal intensity was significant in the therapy group, this can be interpreted as an structural improvement. Also a decrease of the cartilage signal intensity with age was found. The morphological parameters showed no significant changes in the therapy and control groups. (orig.) [Deutsch] Im Rahmen einer prospektiven Studie wurden magnetresonanztomographische Untersuchungen bei Patientinnen mit Fingerpolyarthrose vor und nach Ademetionintherapie durchgefuehrt. Es erfolgten zwei Messungen an einer Kontrollgruppe (n=7, keine Ademetionintherapie) und an der Therapiegruppe (n=14) im Abstand von drei Monaten. Zur Anwendung kamen eine Doppel-Spin-Echo-Sequenz sowie eine 3D-Flash-Sequenz. Ausgewertet wurden neben morphologischen Parametern auch der Signalintensitaetsverlauf im Bereich des hyalinen Gelenkknorpels der Interphalangealgelenke. Signifikant war der Knorpelsignalzuwachs unter Ademetionintherapie, dies kann als Zeichen einer strukturellen Befundbesserung interpretiert werden. Ebenfalls signifikant zeigte sich die Abnahme der Knorpelsignalintensitaet mit zunehmendem Lebensalter der Patientinnen. Bei den morphologischen Befundaenderungen konnte kein signifikanter Therapieeffekt festgestellt werden. (orig.)

  2. Fluid Signal Intensity That Mimicked A Supraspinatus Tendon Tear In A Subacromial Injected Shoulder: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hun; Kim, Tae Eun; Shin, Hyun Woong [Daegu Fatima Hospital, Daegu (Korea, Republic of)

    2010-06-15

    Subacromial steroid injections are a common procedure for treating shoulder pain. Several studies have reported on the difficulty of performing an accurate injection into the subacromial bursa, as well as the injected material infiltrated into other regional structures even when an accurate injection was done into the subacromial space. These misplacements, and especially in the rotator cuff, creates high signal intensity on T2WI that can mimic a rotator cuff tear. Bergman and Fredericson found that the bursal and extrabursal fluid is resolved or decreased 3 days after the injection, so they recommended a 3-day delay after the shoulder injection before performing MRI to prevent misinterpretation of the signal changes. We report here on a case of a false fullthickness tear of the supraspinatus tendon on MRI one month after subacromial injection, and the supraspinatus tendon turned out to be intact on the follow up ultrasonography and arthroscopic examination

  3. Low-intensity pulsed ultrasound accelerates tooth movement via activation of the BMP-2 signaling pathway.

    Directory of Open Access Journals (Sweden)

    Hui Xue

    Full Text Available The present study was designed to determine the underlying mechanism of low-intensity pulsed ultrasound (LIPUS induced alveolar bone remodeling and the role of BMP-2 expression in a rat orthodontic tooth movement model. Orthodontic appliances were placed between the homonymy upper first molars and the upper central incisors in rats under general anesthesia, followed by daily 20-min LIPUS or sham LIPUS treatment beginning at day 0. Tooth movement distances and molecular changes were evaluated at each observation point. In vitro and in vivo studies were conducted to detect HGF (Hepatocyte growth factor/Runx2/BMP-2 signaling pathways and receptor activator of NFκB ligand (RANKL expression by quantitative real time PCR (qRT-PCR, Western blot and immunohistochemistry. At day 3, LIPUS had no effect on the rat orthodontic tooth movement distance and BMP-2-induced alveolar bone remodeling. However, beginning at day 5 and for the following time points, LIPUS significantly increased orthodontic tooth movement distance and BMP-2 signaling pathway and RANKL expression compared with the control group. The qRT-PCR and Western blot data in vitro and in vivo to study BMP-2 expression were consistent with the immunohistochemistry observations. The present study demonstrates that LIPUS promotes alveolar bone remodeling by stimulating the HGF/Runx2/BMP-2 signaling pathway and RANKL expression in a rat orthodontic tooth movement model, and LIPUS increased BMP-2 expression via Runx2 regulation.

  4. Quantitative assessment of the use of modified nucleoside triphosphates in expression profiling: differential effects on signal intensities and impacts on expression ratios

    Directory of Open Access Journals (Sweden)

    Dorris David

    2002-07-01

    Full Text Available Abstract Background The power of DNA microarrays derives from their ability to monitor the expression levels of many genes in parallel. One of the limitations of such powerful analytical tools is the inability to detect certain transcripts in the target sample because of artifacts caused by background noise or poor hybridization kinetics. The use of base-modified analogs of nucleoside triphosphates has been shown to increase complementary duplex stability in other applications, and here we attempted to enhance microarray hybridization signal across a wide range of sequences and expression levels by incorporating these nucleotides into labeled cRNA targets. Results RNA samples containing 2-aminoadenosine showed increases in signal intensity for a majority of the sequences. These results were similar, and additive, to those seen with an increase in the hybridization time. In contrast, 5-methyluridine and 5-methylcytidine decreased signal intensities. Hybridization specificity, as assessed by mismatch controls, was dependent on both target sequence and extent of substitution with the modified nucleotide. Concurrent incorporation of modified and unmodified ATP in a 1:1 ratio resulted in significantly greater numbers of above-threshold ratio calls across tissues, while preserving ratio integrity and reproducibility. Conclusions Incorporation of 2-aminoadenosine triphosphate into cRNA targets is a promising method for increasing signal detection in microarrays. Furthermore, this approach can be optimized to minimize impact on yield of amplified material and to increase the number of expression changes that can be detected.

  5. Brain MR imaging in patients with hepatic cirrhosis: relationship between high intensity signal in basal ganglia on T1-weighted images and elemental concentrations in brain

    International Nuclear Information System (INIS)

    Maeda, H.; Sato, M.; Yoshikawa, A.; Kimura, M.; Sonomura, T.; Terada, M.; Kishi, K.

    1997-01-01

    In patients with hepatic cirrhosis, the globus pallidus and putamen show high intensity on T1-weighted MRI. While the causes of this high signal have been thought to include paramagnetic substances, especially manganese, no evidence for this has been presented. Autopsy in four cases of hepatic cirrhosis permitted measurement of metal concentrations in brain and histopathological examination. In three cases the globus pallidus showed high intensity on T1-weighted images. Mean manganese concentrations in globus pallidus, putamen and frontal white matter were 3.03 ± 0.38, 2.12 ± 0.37, and 1.38 ± 0.24 (μg/g wet weight), respectively, being approximately four- to almost ten-fold the normal values. Copper concentrations in globus pallidus and putamen were also high, 50 % more than normal. Calcium, iron, zinc and magnesium concentrations were all normal. The fourth case showed no abnormal intensity in the basal ganglia and brain metal concentrations were all normal. Histopathologically, cases with showing high signal remarkable atrophy, necrosis, and deciduation of nerve cells and proliferation of glial cells and microglia in globus pallidus. These findings were similar to those in chronic manganese poisoning. On T1-weighted images, copper deposition shows no abnormal intensity. It is therefore inferred that deposition of highly concentrations of manganese may caused high signal on T1-weighted images and nerve cell death in the globus pallidus. (orig.). With 2 figs., 2 tabs

  6. MR signal of the solid portion of pilocytic astrocytoma on T2-weighted images: is it useful for differentiation from medulloblastoma?

    International Nuclear Information System (INIS)

    Arai, Kiyokazu; Yagi, Akiko; Taketomi-Takahashi, Ayako; Morita, Hideo; Koyama, Yoshinori; Endo, Keigo; Sato, Noriko; Aoki, Jun; Oba, Hiroshi; Ishiuchi, Shogo; Saito, Nobuhito

    2006-01-01

    Background and purpose: Although imaging features of cerebellar pilocytic astrocytoma and medulloblastoma have been described in many texts, original comparisons of magnetic resonance intensity between these two tumours are limited. In the present study the results of magnetic resonance imaging (MRI) were reviewed, focusing especially on the signal intensity of the solid portion of these neoplasms. Methods: MR images of ten cerebellar pilocytic astrocytomas and ten medulloblastomas were reviewed. The signal intensities of the solid components were graded on a scale of 1 to 5, with higher scores indicating a signal intensity closer to that of water. The degree of enhancement, tumour cysts and peripheral oedema were evaluated on MR images. When the solid portion was heterogeneous (i.e. mixed signal intensity or degree of enhancement), the dominant area was selected for evaluation. On T2-weighted images, the signal intensity of the solid portion was equal to that of cerebrospinal fluid (CSF) in 50% of pilocytic astrocytomas. No medulloblastomas showed such hyperintensity. Most medulloblastomas (80%) were isointense to grey matter. On T1-weighted images, the signal intensity varied widely in pilocytic astrocytomas; however, all medulloblastomas were iso- or hypointense to grey matter. The MR enhancement pattern, cystic component and peripheral oedema all varied in both tumour types and no specific features were identified. A signal intensity of the solid portion isointense to CSF on T2-weighted images was characteristic of cerebellar pilocytic astrocytomas; this was not observed in medulloblastomas. Attention to T2-weighted imaging of the solid portions of a tumour is easy and helpful in differentiating between cerebellar pilocytic astrocytoma and medulloblastoma. (orig.)

  7. Scaled signal intensity of uterine fibroids based on T2-weighted MR images: a potential objective method to determine the suitability for magnetic resonance-guided focused ultrasound surgery of uterine fibroids.

    Science.gov (United States)

    Park, Hyun; Yoon, Sang-Wook; Sokolov, Amit

    2015-12-01

    Magnetic Resonance-guided Focused Ultrasound Surgery (MRgFUS) is a non-invasive method to treat uterine fibroids. To help determine the patient suitability for MRgFUS, we propose a new objective measure: the scaled signal intensity (SSI) of uterine fibroids in T2 weighted MR images (T2WI). Forty three uterine fibroids in 40 premenopausal women were included in this retrospective study. SSI of each fibroid was measured from the screening T2WI by standardizing its mean signal intensity to a 0-100 scale, using reference intensities of rectus abdominis muscle (0) and subcutaneous fat (100). Correlation between the SSI and the non-perfused volume (NPV) ratio (a measure for treatment success) was calculated. Pre-treatment SSI showed a significant inverse-correlation with post treatment NPV ratio (p < 0.05). When dichotomizing NPV ratio at 45 %, the optimal cut off value of the SSI was found to be 16.0. A fibroid with SSI value 16.0 or less can be expected to have optimal responses. The SSI of uterine fibroids in T2WI can be suggested as an objective parameter to help in patient selection for MRgFUS. • Signal intensity of fibroid in MR images predicts treatment response to MRgFUS. • Signal intensity is standardized into scaled form using adjacent tissues as references. • Fibroids with SSI less than 16.0 are expected to have optimal responses.

  8. [Diagnostic efficiency of decline rate of signal intensity and apparent diffusion coefficient with different b values for differentiating benign and malignant breast lesions on diffusion-weighted 3.0T magnetic resonance imaging].

    Science.gov (United States)

    Jiang, Jing; Liu, Wanhua; Ye, Yuanyuan; Wang, Rui; Li, Fengfang; Peng, Chengyu

    2014-06-17

    To investigate the diagnostic efficiency of decline rate of signal intensity and apparent diffusion coefficient with different b values for differentiating benign and malignant breast lesions on diffusion-weighted 3.0 T magnetic resonance imaging. A total of 152 patients with 162 confirmed histopathologically breast lesions (85 malignant and 77 benign) underwent 3.0 T diffusion-weighted magnetic resonance imaging. Four b values (0, 400, 800 and 1 000 s/mm²) were used. The signal intensity and ADC values of breast lesions were measured respectively. The signal intensity decline rate (SIDR) and apparent diffusion coefficient decline rate (ADCDR) were calculated respectively. SIDR = (signal intensity of lesions with low b value-signal intensity of lesions with high b value)/signal intensity of lesions with low b value, ADCDR = (ADC value of lesions with low b value-ADC value of lesions with high b value) /ADC value of lesions with low b value. The independent sample t-test was employed for statistical analyses and the receiver operating characteristic (ROC) curve for evaluating the diagnosis efficiency of SIDR and ADCDR values. Significant differences were observed in SIDR between benign and malignant breast lesions with b values of 0-400, 400-800 and 800-1 000 s/mm². The sensitivities of SIDR for differentiating benign and malignant breast lesions were 61.2%, 68.2% and 67.1%, the specificities 74.0%, 85.7% and 67.5%, the diagnosis accordance rates 67.3%, 76.5% and 67.3%, the positive predictive values 72.2%, 84.1% and 69.5% and the negative predictive values 63.3%, 71.0% and 65.0% respectively. Significant differences were observed in ADCDR between benign and malignant breast lesions with b values of 400-800 s/mm² and 800-1 000 s/mm². The sensitivities of SDR for differentiating benign and malignant breast lesions were 80.0% and 65.9%, the specificities 72.7% and 65.0%, the diagnostic accordance rates 76.5% and 65.4%, the positive predictive values 76.4% and 67

  9. Determination of eugenol in rat plasma by liquid chromatography-quadrupole ion trap mass spectrometry using a simple off-line dansyl chloride derivatization reaction to enhance signal intensity.

    Science.gov (United States)

    Beaudry, Francis; Guénette, Sarah Annie; Vachon, Pascal

    2006-11-01

    A rapid, selective and sensitive method was developed for the determination of eugenol concentration using an off-line dansyl chloride derivatization step to enhance signal intensity. The method consisted of a protein precipitation extraction followed by derivatization with dansyl chloride and analysis by full scan liquid chromatography electrospray quadrupole ion trap mass spectrometry (LC-ESI-QIT). The separation was achieved using a 100 x 2 mm C(8) analytical column combined with an isocratic mobile phase composed of 75:25 acetonitrile: 0.1% formic acid in water set at a flow rate of 0.25 mL/min. Signal intensity of the eugenol-dansyl chloride derivative was increased up to 100-fold as compared with the underivatized eugenol in positive electrospray mode. An analytical range of 100-20,000 ng/mL was used in the calibration curve of plasma and blood samples. The LOD observed was 0.5 pg injected on column. The novel method met all requirements of specificity, sensitivity, linearity, precision, accuracy and stability. In conclusion, a rapid and sensitive LC-ESI/MS/MS method using a derivatization agent was developed to enhance signal intensity of eugenol. Copyright (c) 2006 John Wiley & Sons, Ltd.

  10. Pixel signal intensity analysis of anterior cruciate ligament grafts in knees with and without intercondylar roof impingement

    International Nuclear Information System (INIS)

    Howell, S.M.; Berns, G.S.; Farley, T.E.; Clark, J.A.

    1990-01-01

    This paper determines if intercondylar roof (IR) impingement produces quantitative, regionalized, and time-dependent differences in the pixel signal intensity (PSI) of anterior cruciate ligament (ACL) grafts. Patients with hamstring autografts were placed into two groups: inpinged (n = 14) and unimpinged (n = 18). MR images were obtained at 3, 6, 9, and over 12 months after operation in the unimpinged group and at 22 months in the impinged group. The PSI was measured along the proximal, middle, and distal thirds of the graft. The PSI was greater in the impinged knees in the distal (P < .008) and middle thirds (P < .009) of the graft, but there was no difference in the proximal third. In the unimpinged group, the signal in all three zones did not change from 3 to 12 months after operation. The tibial tunnel placement was more anterior in the impinged knees (P < .001). Stability (P < .012) and knee extension (P < .003) were better in the unimpinged knees

  11. MIMO Intensity-Modulation Channels: Capacity Bounds and High SNR Characterization

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2016-01-01

    The capacity of MIMO intensity modulation channels is studied. The nonnegativity of the transmit signal (intensity) poses a challenge on the precoding of the transmit signal, which limits the applicability of classical schemes in this type

  12. Signal intensity of lanthanum carbonate on magnetic resonance images: phantom study.

    Science.gov (United States)

    Nakamura, Shinichi; Awai, Kazuo; Komi, Masanori; Morita, Kosuke; Namimoto, Tomohiro; Yanaga, Yumi; Utsunomiya, Daisuke; Date, Shuji; Yamashita, Yasuyuki

    2011-06-01

    Lanthanum carbonate (LC) is used to treat hyperphosphatemia. The purpose of this study was to investigate the signal intensity (SI) of LC on magnetic resonance imaging (MRI) scans of phantoms. LC tablets were thoroughly ground and mixed with distilled water or edible agar (0.05, 0.25, 0.5, and 2.5 mg/ml) in plastic bottles. Four intact tablets were placed in plastic bottles that did or did not contain distilled water or agar. Two radiologists consensually evaluated T1- and T2-weighted images (WIs) obtained with 1.5- and 3.0-T MRI systems for the SI of unground and ground tablets. On T1- and T2WI, the SIs of the LC suspensions and the solvents alone were similar; the SIs of unground tablets alone and of the air were also similar. Unground tablets in phantoms filled with solvent exhibited lower SI than the solvent. Ground tablets in suspension were not visualized on MRI or computed tomography. These results remained unchanged regardless of differences in magnetic field strength or the solvent used. Ground LC had no contrast enhancement effect on T1WI; on T2WI it did not affect the SI of the solvent. Unground LC tablets may be visualized as a "filling defect" on MRI.

  13. Signal intensity of lanthanum carbonate on magnetic resonance images. Phantom study

    International Nuclear Information System (INIS)

    Nakamura, Shinichi; Awai, Kazuo; Namimoto, Tomohiro; Yanaga, Yumi; Utsunomiya, Daisuke; Date, Shuji; Yamashita, Yasuyuki; Komi, Masanori; Morita, Kosuke

    2011-01-01

    Lanthanum carbonate (LC) is used to treat hyperphosphatemia. The purpose of this study was to investigate the signal intensity (SI) of LC on magnetic resonance imaging (MRI) scans of phantoms. LC tablets were thoroughly ground and mixed with distilled water or edible agar (0.05, 0.25, 0.5, and 2.5 mg/ml) in plastic bottles. Four intact tablets were placed in plastic bottles that did or did not contain distilled water or agar. Two radiologists consensually evaluated T1- and T2-weighted images (WIs) obtained with 1.5- and 3.0-T MRI systems for the SI of unground and ground tablets. On T1- and T2WI, the SIs of the LC suspensions and the solvents alone were similar; the SIs of unground tablets alone and of the air were also similar. Unground tablets in phantoms filled with solvent exhibited lower SI than the solvent. Ground tablets in suspension were not visualized on MRI or computed tomography. These results remained unchanged regardless of differences in magnetic field strength or the solvent used. Ground LC had no contrast enhancement effect on T1WI; on T2WI it did not affect the SI of the solvent. Unground LC tablets may be visualized as a 'filling defect' on MRI. (author)

  14. Correlation of non-mass-like abnormal MR signal intensity with pathological findings surrounding pediatric osteosarcoma and Ewing's sarcoma

    International Nuclear Information System (INIS)

    Masrouha, Karim Z.; Haidar, Rachid; Saghieh, Said; Musallam, Khaled M.; Samra, Alexis Bou; Tawil, Ayman; Chakhachiro, Zaher; Abdallah, Abeer; Khoury, Nabil J.; Saab, Raya; Muwakkit, Samar; Abboud, Miguel R.

    2012-01-01

    The aim of this work was to determine the role of MRI in interpreting abnormal signals within bones and soft tissues adjacent to tumor bulk of osteosarcoma and Ewing's sarcoma in a pediatric population by correlating MR findings with histopathology. Thirty patients met the inclusion criteria, which included (1) osteosarcoma or Ewing's sarcoma, (2) MR studies no more than 2 months prior to surgery, (3) presence of abnormal MR signal surrounding the tumor bulk, (4) pathological material from resected tumor. The patients received standard neoadjuvant chemotherapy. Using grid maps on gross pathology specimens, the abnormal MR areas around the tumor were matched with the corresponding grid sections. Histopathology slides of these sections were then analyzed to determine the nature of the regions of interest. The MR/pathological correlation was evaluated using Mann-Whitney U test and Fisher's exact test. Twenty-seven patients had osteosarcoma and three patients had Ewing's sarcoma. Of the studied areas, 17.4% were positive for tumor (viable or necrotic). There was no statistically significant correlation between areas positive for tumor and age, gender, signal extent and intensity on MRI, or tissue type. There was, however, a statistically significant correlation between presence of tumor and the appearance of abnormal soft tissue signals. A feathery appearance correlated with tumor-negative areas whereas a bulky appearance correlated with tumor-positive regions. MR imaging is helpful in identifying the nature of abnormal signal areas surrounding bone sarcomas that are more likely to be tumor-free, particularly when the signal in the soft tissues surrounding the tumor is feathery and edema-like in appearance. (orig.)

  15. Higher-order-mode (HOM) power in elliptical superconducting cavities for intense pulsed proton accelerators

    CERN Document Server

    Sang Ho Kim; Dong O Jeon; Sundeli, R

    2002-01-01

    In linacs for intense pulsed proton accelerators, the beam has a multiple time-structure, and each beam time-structure generates resonance. When a higher-order mode (HOM) is near these resonance frequencies, the induced voltage could be large and accordingly the resulting HOM power, too. In order to understand the effects of a complex beam time-structure on the mode excitations and the resulting HOM powers in elliptical superconducting cavities, analytic expressions are developed, with which the beam-induced voltage and corresponding power are explored, taking into account the properties of HOM frequency behavior in elliptical superconducting cavities. The results and understandings from this analysis are presented with the beam parameters of the Spallation Neutron Source (SNS) superconducting linac.

  16. Increased spontaneous MEG signal diversity for psychoactive doses of ketamine, LSD and psilocybin

    Science.gov (United States)

    Schartner, Michael M.; Carhart-Harris, Robin L.; Barrett, Adam B.; Seth, Anil K.; Muthukumaraswamy, Suresh D.

    2017-04-01

    What is the level of consciousness of the psychedelic state? Empirically, measures of neural signal diversity such as entropy and Lempel-Ziv (LZ) complexity score higher for wakeful rest than for states with lower conscious level like propofol-induced anesthesia. Here we compute these measures for spontaneous magnetoencephalographic (MEG) signals from humans during altered states of consciousness induced by three psychedelic substances: psilocybin, ketamine and LSD. For all three, we find reliably higher spontaneous signal diversity, even when controlling for spectral changes. This increase is most pronounced for the single-channel LZ complexity measure, and hence for temporal, as opposed to spatial, signal diversity. We also uncover selective correlations between changes in signal diversity and phenomenological reports of the intensity of psychedelic experience. This is the first time that these measures have been applied to the psychedelic state and, crucially, that they have yielded values exceeding those of normal waking consciousness. These findings suggest that the sustained occurrence of psychedelic phenomenology constitutes an elevated level of consciousness - as measured by neural signal diversity.

  17. Combination of signal intensity measurements of lesions in the peripheral zone of prostate with MRI and serum PSA level for differentiating benign disease from prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Engelhard, K.; Kreckel, M. [Department of Radiology, Martha-Maria Hospital Nuernberg (Germany); Hollenbach, H.P.; Deimling, M. [Siemens Medical Engineering Group, Erlangen (Germany); Riedl, C. [Dept. of Urology, University of Erlangen-Nuernberg, Erlangen (Germany)

    2000-12-01

    The aim of this study was to predict the benign or malignant nature of a prostatic lesion by defining a threshold value of signal intensity ratio and a limiting value of serum prostate-specific antigen (PSA) in patients with elevated PSA level. Twenty-six patients with elevated PSA level and no hypoechogenic lesions at endosonography underwent MR imaging using an endorectal body phased-array coil at 1.5 T (Siemens Magnetom Symphony). A T2-weighted turbo-spin-echo (TSE) pulse sequence was applied in a transverse orientation. Two radiologists evaluated the images. In the presence of a pathological finding they defined regions of interest (ROI) in the suspicious pathological area of the peripheral zone and in muscle for reference. The quotient of the two ROIs was calculated and then correlated with the actual PSA level. Diagnosis was confirmed by prostate biopsy. Ten of 12 patients with quotients smaller than 4 showed cancer at histology. Nine of 12 men with cancer proven by biopsy had PSA levels higher than 10 ng/ml. A significant difference (p < 0.001) was found between the quotients of cancer and quotients of chronic prostatitis, fibrosis, or glandular atrophy. The accuracy of tumor differentiation of the method was 77 %. Measurement of signal intensity quotients in the peripheral zone of the prostate in combination with knowledge of defined limits of PSA levels the technique could be helpful in detecting additional cancer areas for prostate biopsy. False-negative tumor results of standard sextant biopsy can be reduced. In men with high PSA values the method has a role in differentiating between patients who require prostate biopsy and those of clinical observation. (orig.)

  18. Signal improvement in multiphoton microscopy by reflection with simple mirrors near the sample

    Science.gov (United States)

    Rehberg, Markus; Krombach, Fritz; Pohl, Ulrich; Dietzel, Steffen

    2010-03-01

    In conventional fluorescence or confocal microscopy, emitted light is generated not only in the focal plane but also above and below. The situation is different in multiphoton-induced fluorescence and multiphoton-induced higher harmonic generation. Here, restriction of signal generation to a single focal point permits that all emitted photons can contribute to image formation if collected, regardless of their path through the specimen. Often, the intensity of the emitted light is rather low in biological specimens. We present a method to significantly increase the fraction of photons collected by an epi (backward) detector by placing a simple mirror, an aluminum-coated coverslip, directly under the sample. Samples investigated include fluorescent test slides, collagen gels, and thin-layered, intact mouse skeletal muscles. Quantitative analysis revealed an intensity increase of second- and third-harmonic generated signal in skeletal muscle of nine- and sevenfold respectively, and of fluorescent signal in test slides of up to twofold. Our approach thus allows significant signal improvement also for situations were a forward detection is impossible, e.g., due to the anatomy of animals in intravital microscopy.

  19. MR imaging of hepatocellular carcinoma. Correlation of metal content and signal intensity

    International Nuclear Information System (INIS)

    Honda, H.; Onitsuka, H.; Kanazawa, Y.; Matsumata, T.; Hayashi, T.; Kaneko, K.; Fukaya, T.; Tateshi, Y.; Adachi, E.; Masuda, K.

    1995-01-01

    In order to clarify the factors contributing to the signal intensities (SIs) of HCC on T1-weighted images, the amount of water, lipid, copper (Cu), iron (Fe), and manganese (Mn) was determined in HCC and surrounding hepatic parenchyma of 13 patients. The relationships among these findings, the histopathologic findings, and the SIs of T1-weighted images were evaluated. Among the 13 HCC, 3 had a high SI, 5 were isointense, and 5 had a low SI on T1-weighted images compared to the surrounding hepatic parenchyma. The paramagnetic ions which contributed to the SI patterns were assumed to be Cu in HCC (38.0±62.4 μg/g ww), and Fe in the liver (61.1±42.4 μg/g ww) and HCC (40.0±34.3 μg/g ww). In 8 HCC with high- or isointensity, 2 were grades I, 5 were grade II, and one was grade III according to the Edmondson-Steiner's histopathologic classification. It is concluded that the SI patterns alone can not be a sign of low grade malignancy because of the existence of Fe in livers and HCC. (orig.)

  20. Self-Regulated Learning Skills and Online Activities between Higher and Lower Performers on a Web-Intensive Undergraduate Engineering Course

    Science.gov (United States)

    Lawanto, Oenardi; Santoso, Harry B.; Lawanto, Kevin N.; Goodridge, Wade

    2017-01-01

    The objective of this study was to evaluate students' self-regulated learning (SRL) skills used in a Web-intensive learning environment. The research question guiding the study was: How did the use of student SRL skills and student engagement in online activities compare between higher- and lower-performing students participating in a…

  1. Moderate plasma treatment enhances the quality of optically detected magnetic resonance signals of nitrogen-vacancy centres in nanodiamonds

    Science.gov (United States)

    Sotoma, Shingo; Igarashi, Ryuji; Shirakawa, Masahiro

    2016-05-01

    We demonstrate that a moderate plasma treatment increases the quality of optically detected magnetic resonance (ODMR) signals from negatively charged nitrogen-vacancy centres in nanodiamonds (NDs). We measured the statistics of the ODMR spectra of 50-nm-size NDs before and after plasma treatment. We then evaluated each ODMR spectrum in terms of fluorescence and ODMR intensities, line width and signal-to-noise (SN) ratio. Our results showed that plasma treatment for more than 10 min contributes to higher-quality ODMR signals, i.e. signals that are brighter, stronger, sharper and have a higher SN ratio. We showed that such signal improvement is due to alteration of the surface chemical states of the NDs by the plasma treatment. Our study contributes to the advancement of biosensing applications using ODMR of NDs.

  2. 10Be and relative paleointensity signals across the last geomagnetic reversal

    Science.gov (United States)

    Savranskaia, T.; Valet, J. P.; Bassinot, F. C.; Meynadier, L.; Simon, Q.; Bourles, D. L.; Thouveny, N.; Thevarasan, A.; Villedieu, A.; Choy, S.; Gacem, L.

    2017-12-01

    Two techniques can be used to determine the evolution of the geomagnetic field intensity in the past. The first one relies on records of relative paleointensity (RPI) in sediments. Although they remain relatively sparse detailed records of 10Be production (expressed in terms of 10Be/9Be) provide an alternative approach. However integration of 10Be within the sediment is not better understood than the magnetization process, and therefore paleofield studies should greatly benefit from the integration of both datasets. In order to achieve this goal, it is crucial to compare and analyze the signals over a common time period. We selected five sedimentary cores from the Indian, Pacific and Atlantic Oceans and focused on the last reversal which is characterized by the largest intensity changes. Since 10Be is homogenized in the atmosphere, the same amount of 10Be should be recorded everywhere. We found different amounts of 10Be at each site during the last reversal which appear roughly correlated with accumulation rate. In contrast the 10Be amplitude is similar at all locations while higher amplitude signals are expected for low deposition rates. Taking advantage of the distribution of tektites layers, the beryllium signals have been deconvolved, but this procedure did not strikingly change the results. Despite atmospheric mixing we wonder whether 10Be production was slightly different at each location in presence of a multipolar transitional field. The comparison between the 10Be and RPI signals reveals large similarities but also puzzling differences. In particular, the relationship between the two signals is not the same during periods of stable polarity as during the transitional interval. A precursor with low intensity is present in several RPI records but not clearly marked on the beryllium records. We also addressed the question of a possible offset between the two signals that would be indicative of a delayed magnetization acquisition. After correlating and

  3. Uterine Artery Embolization for Symptomatic Fibroids with High Signal Intensity on T2-Weighted MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Suyon; Kim, Man Deuk; Lee, Myung Su; Lee, Mu Sook; Park, Sung Il; Won, Jong Yun; Lee, Do Yun; Lee, Kwang Hun [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Severance Hospital, Seoul (Korea, Republic of)

    2012-09-15

    To evaluate the effectiveness of uterine artery embolization (UAE) for treating symptomatic fibroids with high signal intensity (SI) on magnetic resonance (MR) T2-weighted imaging (T2WI). A total of 537 cases, consisting of 14 patients with high SI fibroids on T2WI (T2 high group), were retrospectively included and compared with 28 randomly selected patients with low SI fibroids on T2WI (control group). High SI of a predominant fibroid on T2WI was defined as having the same or higher SI than the myometrium. Patient ages ranged from 28 to 52 years (mean, 38.1 years). All patients underwent MRI before and after UAE. Predominant fibroid and uterine volumes were calculated with MR images. Symptom status in terms of menorrhagia and dysmenorrhea was scored on a scale of 0-10, with 0 being no symptoms and 10 being the baseline, or initial symptoms. Of the patients in the T2 high group, 13 out of 14 (92.9%) patients demonstrated complete necrosis of the predominant fibroids. The mean volume reduction rates of the predominant fibroids in the T2 high group was 61.7% at three months after UAE, which was significantly higher than the volume reduction rates of 42.1% noted in the control group (p < 0.05). Changes in symptom scores for menorrhagia and dysmenorrhea after UAE (baseline score minus follow-up score) were 4.9 and 7.5 in T2 high group and they were 5.0 and 7.7 in control group, suggesting a significant resolution of symptoms (p < 0.01) in both groups but no significant difference between the two groups. UAE is effective for uttering fibroids showing high SI on T2WI. The mean volume reduction rate of the predominant fibroids three months after UAE was greater in the T2 high group than in the control group.

  4. Uterine Artery Embolization for Symptomatic Fibroids with High Signal Intensity on T2-Weighted MR Imaging

    International Nuclear Information System (INIS)

    Chang, Suyon; Kim, Man Deuk; Lee, Myung Su; Lee, Mu Sook; Park, Sung Il; Won, Jong Yun; Lee, Do Yun; Lee, Kwang Hun

    2012-01-01

    To evaluate the effectiveness of uterine artery embolization (UAE) for treating symptomatic fibroids with high signal intensity (SI) on magnetic resonance (MR) T2-weighted imaging (T2WI). A total of 537 cases, consisting of 14 patients with high SI fibroids on T2WI (T2 high group), were retrospectively included and compared with 28 randomly selected patients with low SI fibroids on T2WI (control group). High SI of a predominant fibroid on T2WI was defined as having the same or higher SI than the myometrium. Patient ages ranged from 28 to 52 years (mean, 38.1 years). All patients underwent MRI before and after UAE. Predominant fibroid and uterine volumes were calculated with MR images. Symptom status in terms of menorrhagia and dysmenorrhea was scored on a scale of 0-10, with 0 being no symptoms and 10 being the baseline, or initial symptoms. Of the patients in the T2 high group, 13 out of 14 (92.9%) patients demonstrated complete necrosis of the predominant fibroids. The mean volume reduction rates of the predominant fibroids in the T2 high group was 61.7% at three months after UAE, which was significantly higher than the volume reduction rates of 42.1% noted in the control group (p < 0.05). Changes in symptom scores for menorrhagia and dysmenorrhea after UAE (baseline score minus follow-up score) were 4.9 and 7.5 in T2 high group and they were 5.0 and 7.7 in control group, suggesting a significant resolution of symptoms (p < 0.01) in both groups but no significant difference between the two groups. UAE is effective for uttering fibroids showing high SI on T2WI. The mean volume reduction rate of the predominant fibroids three months after UAE was greater in the T2 high group than in the control group.

  5. Signal enhancement by spectral equalization of high frequency broadband signals transmitted through optical fibers

    International Nuclear Information System (INIS)

    Lyons, P.B.; Ogle, J.W.; Holzman, M.A.

    1980-01-01

    A new technique is discussed for enhancing the bandwidth and intensity of high frequency (> 1 GHz) analog, spectrally broad (40 nm) signals transmitted through one kilometer of optical fiber. The existing method for bandwidth enhancement of such a signal uses a very narrow (approx. 1 nm) filter between the fiber and detector to limit bandwidth degradation due to material dispersion. Using this method, most of the available optical intensity is rejected and lost. This new technique replaces the narrow-band filter with a spectral equalizer device which uses a reflection grating to disperse the input signal spectrum and direct it onto a linear array of fibers

  6. Analysis of small-signal intensity modulation of semiconductor ...

    Indian Academy of Sciences (India)

    Computer simulation of the model is applied to 1.55-µm ... Semiconductor laser; small-signal modulation; modulation response; gain suppression. ... originates from intraband relaxation processes of charge carriers that extend for times as ...

  7. Comparative Analysis of Signal Intensity and Apparent Diffusion Coefficient at Varying b-values in the Brain : Diffusion Weighted-Echo Planar Image (T2 and FLAIR) Sequence

    International Nuclear Information System (INIS)

    Oh, Jong Kap; Im, Jung Yeol

    2009-01-01

    Diffusion-weighted imaging (DWI) has been demonstrated to be a practical method for the diagnosis of various brain diseases such as acute infarction, brain tumor, and white matter disease. In this study, we used two techniques to examine the average signal intensity (SI) and apparent diffusion coefficient (ADC) of the brains of patients who ranged in age from 10 to 60 years. Our results indicated that the average SI was the highest in amygdala (as derived from DWI), whereas that in the cerebrospinal fluid was the lowest. The average ADC was the highest in the cerebrospinal fluid, whereas the lowest measurement was derived from the pons. The average SI and ADC were higher in T 2 -DW-EPI than in FLAIR-DW-EPI. The higher the b-value, the smaller the average difference in both imaging techniques; the lower the b-value, the greater the average difference. Also, comparative analysis of the brains of patients who had experienced cerebral infarction showed no distinct lesion in the general MR image over time. However, there was a high SI in apparent weighted images. Analysis of other brain diseases (e.g., bleeding, acute, subacute, chronic infarction) indicated SI variance in accordance with characteristics of the two techniques. The higher the SI, the lower the ADC. Taken together, the value of SI and ADC in accordance with frequently occurring areas and various brain disease varies based on the b-value and imaging technique. Because they provide additional useful information in the diagnosis and treatment of patients with various brain diseases through signal recognition, the proper imaging technique and b-value are important for the detection and interpretation of subacute stroke and other brain diseases.

  8. Alternatives to Pyrotechnic Distress Signals; Additional Signal Evaluation

    Science.gov (United States)

    2017-06-01

    device performance standard that addresses Coast Guard project sponsor and stakeholders needs. 17. Key Words Visual Distress Signal Device (VDSD...devices. The report discussed the concept of “effective intensity,” as used by the International Association of Marine Aids to Navigation and Lighthouse...efficacy of Cyan as a signal color. In order to move forward, the RDC project team met with CG-ENG-4 and other Coast Guard stakeholders (Offices of

  9. The intensity detection of single-photon detectors based on photon counting probability density statistics

    International Nuclear Information System (INIS)

    Zhang Zijing; Song Jie; Zhao Yuan; Wu Long

    2017-01-01

    Single-photon detectors possess the ultra-high sensitivity, but they cannot directly respond to signal intensity. Conventional methods adopt sampling gates with fixed width and count the triggered number of sampling gates, which is capable of obtaining photon counting probability to estimate the echo signal intensity. In this paper, we not only count the number of triggered sampling gates, but also record the triggered time position of photon counting pulses. The photon counting probability density distribution is obtained through the statistics of a series of the triggered time positions. Then Minimum Variance Unbiased Estimation (MVUE) method is used to estimate the echo signal intensity. Compared with conventional methods, this method can improve the estimation accuracy of echo signal intensity due to the acquisition of more detected information. Finally, a proof-of-principle laboratory system is established. The estimation accuracy of echo signal intensity is discussed and a high accuracy intensity image is acquired under low-light level environments. (paper)

  10. Purification and Concentration of PCR Products Leads to Increased Signal intensities with Fewer Allelic Drop-Outs and Artifacts

    DEFF Research Database (Denmark)

    Maria Irlund Pedersen, Line; Stangegaard, Michael; Mogensen, Helle Smidt

    2011-01-01

    and the quality of the DNA profiles without re-amplification of the sample. We have validated and implemented an automated method to purify and 2-fold concentrate PCR products resulting in allelic peaks with higher intensity (a median height across all loci from 130 to 404 RFU), fewer allelic dropouts...

  11. Comparison of higher order spectra in heart rate signals during two techniques of meditation: Chi and Kundalini meditation.

    Science.gov (United States)

    Goshvarpour, Ateke; Goshvarpour, Atefeh

    2013-02-01

    The human heartbeat is one of the important examples of complex physiologic fluctuations. For the first time in this study higher order spectra of heart rate signals during meditation have explored. Specifically, the aim of this study was to analysis and compares the contribution of quadratic phase coupling of human heart rate variability during two forms of meditation: (1) Chinese Chi (or Qigong) meditation and (2) Kundalini Yoga meditation. For this purpose, Bispectrum was estimated by using biased, parametric and the direct (FFT) method. The results show that the mean Bispectrum magnitude of heart rate signals increased during Kundalini Yoga meditation, but it decreased significantly during Chi meditation. However, in both meditation techniques phase-coupled harmonics are shifted to the higher frequencies during meditation. In addition, it has shown that not only there are significant differences between rest and meditation states, but also heart rate patterns appear to be influenced by different types of meditation.

  12. Leptomeningeal high signal intensity (ivy sign) on fluid-attenuated inversion-recovery (FLAIR) MR images in moyamoya disease

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Hirokazu [Department of Diagnostic Radiology, School of Medicine, Keio University, Tokyo 1608582 (Japan)]. E-mail: hirokazu_fujiwara@ybb.ne.jp; Momoshima, Suketaka [Department of Diagnostic Radiology, School of Medicine, Keio University, Tokyo 1608582 (Japan); Kuribayashi, Sachio [Department of Diagnostic Radiology, School of Medicine, Keio University, Tokyo 1608582 (Japan)

    2005-08-01

    Purpose: There are a few reports on leptomeningeal high signal intensity (LMHI: ivy sign) on fluid-attenuated inversion-recovery (FLAIR) images in moyamoya disease, but the feature of this finding has not been completely understood. The purpose of this study was to characterize LMHI on FLAIR images in moyamoya disease and to assess usefulness of this finding in the diagnosis of moyamoya disease in conventional MR imaging. Material and methods: MR imaging of 28 patients with moyamoya disease was retrospectively reviewed. The grade of LMHI on FLAIR images was classified as 'absent,' 'minimal,' 'moderate' and 'marked.' Fifty-four hemispheres of 28 patients (2 patients had unilateral disease) were assessed for the frequency of visualization and distribution of LMHI. The correlations between LMHI on FLAIR images, moyamoya vessels on T1- and T2-weighted images and MR angiography findings were also analyzed. Results: Moderate and marked LMHI was seen in 31 out of 54 hemispheres (57%). LMHI was seen more prominently in the frontal and parietal lobes than in the temporal and occipital lobes. Although there was a tendency for LMHI on FLAIR images to be prominent in groups with moderate and marked moyamoya vessels on T1- and T2-weighted images, there was no significant correlation. More prominent LMHI was observed in the hemispheres in which cortical branches of the middle cerebral arteries were poorly visualized on MR angiography. Conclusion: Leptomeningeal high signal intensity (ivy sign) on FLAIR images is predominantly seen in the frontal and parietal lobes. Because this sign can be seen in patients with unremarkable moyamoya vessels, LMHI is a useful sign in conventional MR imaging for the diagnosis of moyamoya disease.

  13. Characterization of organic materials by LIBS for exploration of correlation between molecular and elemental LIBS signals

    Directory of Open Access Journals (Sweden)

    Shikha Rai

    2011-12-01

    Full Text Available The present study is performed for the preparation of a database by accumulating LIBS spectra of 4-nitroaniline and 4-nitrotoluene in air and argon. Changes in the behavior of the molecular bands of the C2 Swan system and CN violet system as well as of atomic lines of C, H and N in the LIBS signal are appreciable in argon. In order to explore the correlation between observed LIBS signal and molecular composition of these materials, normalized intensities of the emission lines have been estimated for each compound. It has been found that the relative rates of increase/decrease in the normalized intensities for all sets are higher for 4-nitrotoluene in argon. The cause of the higher rate for 4-nitrotoluene might be due to the possession of a distinctive functional group. The ultimate goal behind the whole study is to use this data-base as input for the discrimination of energetic materials.

  14. Influence of Signal Intensity Non-Uniformity on Brain Volumetry Using an Atlas-Based Method

    International Nuclear Information System (INIS)

    Takao, Hidemasa; Kunimatsu, Akira; Mori, Harushi

    2012-01-01

    Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 X[measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials.

  15. Influence of signal intensity non-uniformity on brain volumetry using an atlas-based method.

    Science.gov (United States)

    Goto, Masami; Abe, Osamu; Miyati, Tosiaki; Kabasawa, Hiroyuki; Takao, Hidemasa; Hayashi, Naoto; Kurosu, Tomomi; Iwatsubo, Takeshi; Yamashita, Fumio; Matsuda, Hiroshi; Mori, Harushi; Kunimatsu, Akira; Aoki, Shigeki; Ino, Kenji; Yano, Keiichi; Ohtomo, Kuni

    2012-01-01

    Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 × [measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials.

  16. Influence of Signal Intensity Non-Uniformity on Brain Volumetry Using an Atlas-Based Method

    Energy Technology Data Exchange (ETDEWEB)

    Takao, Hidemasa; Kunimatsu, Akira; Mori, Harushi [University of Tokyo Hospital, Tokyo (Japan); and others

    2012-07-15

    Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 X[measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials.

  17. Nutrient concentrations in a Littorella uniflora community at higher CO2 concentrations and reduced light intensities

    DEFF Research Database (Denmark)

    Andersen, T.; Pedersen, O.; Andersen, F. Ø.

    2005-01-01

    laboratory experiments with isoetid vegetation (Littorella uniflora) where water column CO2 and light could be manipulated in order to test whether (i) light and CO2 availability affect nutrient concentrations in isoetid vegetation, and (ii) if changes in light and CO2 climate affect fluxes of inorganic...... nitrogen (N) and phosphorus (P) from sediment to water column, which potentially could result in increased growth of epiphytic algae. 3. The results showed that the standing stocks of phosphorus and nitrogen in the L. uniflora vegetation were significantly influenced by CO2 concentration and light...... intensity. Both standing stocks of P and N were significantly higher in the mesocosm treatments with high CO2 concentration than in those at low CO2 concentration. Similarly, standing stocks of P and N enhanced with increasing light intensity. 4. Measurements of nutrient fluxes both in the field...

  18. Low intensity exercise prevents disturbances in rat cardiac insulin signaling and endothelial nitric oxide synthase induced by high fructose diet.

    Science.gov (United States)

    Stanišić, Jelena; Korićanac, Goran; Ćulafić, Tijana; Romić, Snježana; Stojiljković, Mojca; Kostić, Milan; Pantelić, Marija; Tepavčević, Snežana

    2016-01-15

    Increase in fructose consumption together with decrease in physical activity contributes to the development of metabolic syndrome and consequently cardiovascular diseases. The current study examined the preventive role of exercise on defects in cardiac insulin signaling and function of endothelial nitric oxide synthase (eNOS) in fructose fed rats. Male Wistar rats were divided into control, sedentary fructose (received 10% fructose for 9 weeks) and exercise fructose (additionally exposed to low intensity exercise) groups. Concentration of triglycerides, glucose, insulin and visceral adipose tissue weight were determined to estimate metabolic syndrome development. Expression and/or phosphorylation of cardiac insulin receptor (IR), insulin receptor substrate 1 (IRS1), tyrosine-specific protein phosphatase 1B (PTP1B), Akt, extracellular signal-regulated protein kinases 1 and 2 (ERK1/2) and eNOS were evaluated. Fructose overload increased visceral adipose tissue, insulin concentration and homeostasis model assessment index. Exercise managed to decrease visceral adiposity and insulin level and to increase insulin sensitivity. Fructose diet increased level of cardiac PTP1B and pIRS1 (Ser307), while levels of IR and ERK1/2, as well as pIRS1 (Tyr 632), pAkt (Ser473, Thr308) and pERK1/2 were decreased. These disturbances were accompanied by reduced phosphorylation of eNOS at Ser1177. Exercise managed to prevent most of the disturbances in insulin signaling caused by fructose diet (except phosphorylation of IRS1 at Tyr 632 and phosphorylation and protein expression of ERK1/2) and consequently restored function of eNOS. Low intensity exercise could be considered as efficient treatment of cardiac insulin resistance induced by fructose diet. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Adopting an Active Learning Approach to Teaching in a Research-Intensive Higher Education Context Transformed Staff Teaching Attitudes and Behaviours

    Science.gov (United States)

    White, Paul J.; Larson, Ian; Styles, Kim; Yuriev, Elizabeth; Evans, Darrell R.; Rangachari, P. K.; Short, Jennifer L.; Exintaris, Betty; Malone, Daniel T.; Davie, Briana; Eise, Nicole; Mc Namara, Kevin; Naidu, Somaiya

    2016-01-01

    The conventional lecture has significant limitations in the higher education context, often leading to a passive learning experience for students. This paper reports a process of transforming teaching and learning with active learning strategies in a research-intensive educational context across a faculty of 45 academic staff and more than 1,000…

  20. Comparative Analysis of Signal Intensity and Apparent Diffusion Coefficient at Varying b-values in the Brain : Diffusion Weighted-Echo Planar Image (T{sub 2} and FLAIR) Sequence

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jong Kap [Dept. of Radiology, Cheomdan Medical Center, Gwangju (Korea, Republic of); Im, Jung Yeol [Dept. of Digital Management Information Graduate School of Nambu Univesity, Gwangju (Korea, Republic of)

    2009-09-15

    Diffusion-weighted imaging (DWI) has been demonstrated to be a practical method for the diagnosis of various brain diseases such as acute infarction, brain tumor, and white matter disease. In this study, we used two techniques to examine the average signal intensity (SI) and apparent diffusion coefficient (ADC) of the brains of patients who ranged in age from 10 to 60 years. Our results indicated that the average SI was the highest in amygdala (as derived from DWI), whereas that in the cerebrospinal fluid was the lowest. The average ADC was the highest in the cerebrospinal fluid, whereas the lowest measurement was derived from the pons. The average SI and ADC were higher in T{sub 2}-DW-EPI than in FLAIR-DW-EPI. The higher the b-value, the smaller the average difference in both imaging techniques; the lower the b-value, the greater the average difference. Also, comparative analysis of the brains of patients who had experienced cerebral infarction showed no distinct lesion in the general MR image over time. However, there was a high SI in apparent weighted images. Analysis of other brain diseases (e.g., bleeding, acute, subacute, chronic infarction) indicated SI variance in accordance with characteristics of the two techniques. The higher the SI, the lower the ADC. Taken together, the value of SI and ADC in accordance with frequently occurring areas and various brain disease varies based on the b-value and imaging technique. Because they provide additional useful information in the diagnosis and treatment of patients with various brain diseases through signal recognition, the proper imaging technique and b-value are important for the detection and interpretation of subacute stroke and other brain diseases.

  1. Localization of Coronary High-Intensity Signals on T1-Weighted MR Imaging: Relation to Plaque Morphology and Clinical Severity of Angina Pectoris.

    Science.gov (United States)

    Matsumoto, Kenji; Ehara, Shoichi; Hasegawa, Takao; Sakaguchi, Mikumo; Otsuka, Kenichiro; Yoshikawa, Junichi; Shimada, Kenei

    2015-10-01

    This study sought to investigate the relationship between localization of high-intensity signals (HISs) on T1-weighted imaging (T1WI) with the noncontrast magnetic resonance technique and plaque morphology detected on optical coherence tomography, and the clinical severity of angina pectoris. Since the introduction of the T1WI noncontrast magnetic resonance technique for plaque imaging, some groups have reported that HISs in the coronary artery on T1WI are associated with a vulnerable morphology and future cardiac events. However, the association between the localization of HISs, such as coronary intrawall or intraluminal, and plaque morphology has not been investigated. One hundred lesions with either stable or unstable angina were included and divided into 3 groups according to the following criteria using T1WI. First, the plaques with the ratio between the signal intensities of coronary plaque and cardiac muscle ≤1.0 were classified as non-HISs (n = 39). Then, HISs with the ratio between the signal intensities of coronary plaque and cardiac muscle >1.0 were classified into 2 types by using cross-sectional T1WI. Those localized within the coronary wall when the lumen was identified were defined as intrawall HISs (n = 37), whereas those occupying the lumen when the lumen was not, or even if only partly, identified, were defined as intraluminal HISs (n = 24). Multivariate analysis revealed that intrawall HISs were associated with macrophage accumulation and the absence of calcification assessed by using optical coherence tomography. In contrast, thrombus and intimal vasculature were independent factors associated with intraluminal HISs. Furthermore, 50% of patients with intraluminal HISs experienced rest angina, such as Braunwald class II or III. This study shows that intrawall and intraluminal HISs on T1WI in patients with angina are related to the different types of vulnerable plaque morphology and the clinical severity. Copyright © 2015 American College of

  2. LM-OSL signals from some insulators: an analysis of the dependency of the detrapping probability on stimulation light intensity

    DEFF Research Database (Denmark)

    Bulur, E.; Bøtter-Jensen, L.; Murray, A.S.

    2001-01-01

    Optically stimulated luminescence (OSL) signals from various insulators including quartz, Al2O3 : C, BeO and NaCl have been studied using the linear modulation OSL (LM-OSL) technique. LM-OSL is based on the linear increase of the stimulation light power from zero to a maximum during the measurement...... is not always correct. The initial decay rates of the blue (similar to 470 nm) light stimulated constant power OSL decay curves were examined to test the relation between the detrapping rates and the stimulation light intensity. In SiO2, Al2O3 : C and BeO a linear relation between the detrapping rates....... The resultant OSL curve initially increases and then decays after reaching a maximum, The analysis of LM-OSL data usually assumes a linear relationship between the detrapping rate and the stimulation light intensity. However, experiments carried out using various insulators have shown that this assumption...

  3. MRI of symptomatic Rathke`s cleft cyst. MR intensity of cyst contents and clinical manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Takeichi, Yasuhiro [Soseikai General Hospital, Kyoto (Japan); Nakasu, Yoko; Handa, Jyoji

    1997-07-01

    We have not known surgical indications for incidental Rathke`s cleft cysts, because of our lack of knowledge about their natural history. In this study, we investigated whether symptomatic Rathke`s cleft cysts have any characteristic features in magnetic resonance (MR) signal intensities, and analyzed their relation to clinical manifestations and to patterns of suprasellar expansion. MR signal intensities on T1-weighted (T1W) and T2-weighted (T2W) images were categorized into 3 types in 78 cases including our 9 cases; type I, low signal intensity on T1W images and hyperintensity on T2W images in 25 cases; type II, hyperintensity on both T1W and T2W images in 20; and type III, low intensity on T2W images, in other 33. Patients of type I signal intensities presented with significantly high percentage of large cysts compressing the third ventricle than patients with other types. The patients of type I signal intensities also frequently had visual disturbance. Patients in type II showed significantly less percentage of large cysts. Anterior pituitary dysfunction was observed more often in patients of type II and III than patients of type I. We conclude that Rathke`s cleft cysts with MR signal intensity like cerebrospinal fluid (CSF) are slowly growing, and are frequently diagnosed as large cysts associated with visual disturbance. The patients with other types of MR signal intensities may suffer pituitary dysfunction or other symptoms before the cysts compress the hypothalamic region. The assessment of MR signal intensities may contribute in predicting clinical progression in patients with Rathke`s cleft cysts. (author)

  4. Toward a Miami University Model for Internet-Intensive Higher Education.

    Science.gov (United States)

    Wolfe, Christopher R.; Crider, Linda; Mayer, Larry; McBride, Mark; Sherman, Richard; Vogel, Robert

    1998-01-01

    Describes principles underlying an emerging model for Internet-intensive undergraduate instruction at Miami University (Ohio) in which students learn by creating online materials themselves; faculty facilitate active learning; student intellectual exchanges are enriched; and the seminar sensibility is extended. Four applications are examined: a…

  5. Cardiorespiratory fitness modulates the acute flow-mediated dilation response following high-intensity but not moderate-intensity exercise in elderly men.

    Science.gov (United States)

    Bailey, Tom G; Perissiou, Maria; Windsor, Mark; Russell, Fraser; Golledge, Jonathan; Green, Daniel J; Askew, Christopher D

    2017-05-01

    Impaired endothelial function is observed with aging and in those with low cardiorespiratory fitness (V̇o 2peak ). Improvements in endothelial function with exercise training are somewhat dependent on the intensity of exercise. While the acute stimulus for this improvement is not completely understood, it may, in part, be due to the flow-mediated dilation (FMD) response to acute exercise. We examined the hypothesis that exercise intensity alters the brachial (systemic) FMD response in elderly men and is modulated by V̇o 2peak Forty-seven elderly men were stratified into lower (V̇o 2peak = 24.3 ± 2.9 ml·kg -1 ·min -1 ; n = 27) and higher fit groups (V̇o 2peak = 35.4 ± 5.5 ml·kg -1 ·min -1 ; n = 20) after a test of cycling peak power output (PPO). In randomized order, participants undertook moderate-intensity continuous exercise (MICE; 40% PPO) or high-intensity interval cycling exercise (HIIE; 70% PPO) or no-exercise control. Brachial FMD was assessed at rest and 10 and 60 min after exercise. FMD increased after MICE in both groups {increase of 0.86% [95% confidence interval (CI), 0.17-1.56], P = 0.01} and normalized after 60 min. In the lower fit group, FMD was reduced after HIIE [reduction of 0.85% (95% CI, 0.12-1.58), P = 0.02] and remained decreased at 60 min. In the higher fit group, FMD was unchanged immediately after HIIE and increased after 60 min [increase of 1.52% (95% CI, 0.41-2.62), P exercise control, FMD was reduced in both groups after 60 min ( P = 0.05). Exercise intensity alters the acute FMD response in elderly men and V̇o 2peak modulates the FMD response following HIIE but not MICE. The sustained decrease in FMD in the lower fit group following HIIE may represent a signal for vascular adaptation or endothelial fatigue. NEW & NOTEWORTHY This study is the first to show that moderate-intensity continuous cycling exercise increased flow-mediated dilation (FMD) transiently before normalization of FMD after 1 h, irrespective of

  6. Clinical significance of subchondral cortical signal intensities in osteoarthritis of knee joints

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Eijiro; Torisu, Takehiko; Nakamura, Taro; Masumi, Shogo [Oita Medical Univ., Hazama (Japan); Tomari, Kazuhide; Asao, Tunenori; Takagi, Kazuhiro

    1996-09-01

    The purpose of this study was to evaluate the abnormal intensity in medial femoral condyle on MR imaging in patients with osteoarthritis of the knee. Eighty knees of fifty-eight patients with osteoarthritis of the knee were underwent plain radiography and MR imaging. According to the extension of the abnormal low intensity on T{sub 1} weighted images in medial femoral chondyle, all cases were classified into four types (no exist: 30.0%, small: 30.0%, middle: 30.0%, large: 10.0%). The extension of the abnormal low intensity was closely related to radiographic stage and femoral tibial angle. After radiological examination, in thirteen knees, the biopsy of the abnormal low intensity area on T{sub 1} weighted MR imaging was performed at the time of total knee arthroplasty. Pathological examination revealed that the causative factor of abnormal low intensity on T{sub 1} weighted MR imaging in the medial femoral condyle was trabecular hypertrophy. Our results suggest that the abnormal low intensity on T{sub 1} weighted MR imaging reflects the loading force. (author)

  7. Clinical significance of subchondral cortical signal intensities in osteoarthritis of knee joints

    International Nuclear Information System (INIS)

    Nakamura, Eijiro; Torisu, Takehiko; Nakamura, Taro; Masumi, Shogo; Tomari, Kazuhide; Asao, Tunenori; Takagi, Kazuhiro.

    1996-01-01

    The purpose of this study was to evaluate the abnormal intensity in medial femoral condyle on MR imaging in patients with osteoarthritis of the knee. Eighty knees of fifty-eight patients with osteoarthritis of the knee were underwent plain radiography and MR imaging. According to the extension of the abnormal low intensity on T 1 weighted images in medial femoral chondyle, all cases were classified into four types (no exist: 30.0%, small: 30.0%, middle: 30.0%, large: 10.0%). The extension of the abnormal low intensity was closely related to radiographic stage and femoral tibial angle. After radiological examination, in thirteen knees, the biopsy of the abnormal low intensity area on T 1 weighted MR imaging was performed at the time of total knee arthroplasty. Pathological examination revealed that the causative factor of abnormal low intensity on T 1 weighted MR imaging in the medial femoral condyle was trabecular hypertrophy. Our results suggest that the abnormal low intensity on T 1 weighted MR imaging reflects the loading force. (author)

  8. Discoscopic Findings of High Signal Intensity Zones on Magnetic Resonance Imaging of Lumbar Intervertebral Discs

    Directory of Open Access Journals (Sweden)

    Kosuke Sugiura

    2014-01-01

    Full Text Available A 32-year-old man underwent radiofrequency thermal annuloplasty (TA with percutaneous endoscopic discectomy (PED under local anesthesia for chronic low back pain. His diagnosis was discogenic pain with a high signal intensity zone (HIZ in the posterior corner of the L4-5 disc. Flexion pain was sporadic, and steroid injection was given twice for severe pain. After the third episode of strong pain, PED and TA were conducted. The discoscope was inserted into the posterior annulus and revealed a migrated white nucleus pulposus which was stained blue. Then, after moving the discoscope to the site of the HIZ, a migrated slightly red nucleus pulposus was found, suggesting inflammation and/or new vessels penetrating the mass. After removing the fragment, the HIZ site was ablated by TA. To our knowledge, this is the first report of the discoscopic findings of HIZ of the lumbar intervertebral disc.

  9. Including dynamic CO2 intensity with demand response

    International Nuclear Information System (INIS)

    Stoll, Pia; Brandt, Nils; Nordström, Lars

    2014-01-01

    Hourly demand response tariffs with the intention of reducing or shifting loads during peak demand hours are being intensively discussed among policy-makers, researchers and executives of future electricity systems. Demand response rates have still low customer acceptance, apparently because the consumption habits requires stronger incentive to change than any proposed financial incentive. An hourly CO 2 intensity signal could give customers an extra environmental motivation to shift or reduce loads during peak hours, as it would enable co-optimisation of electricity consumption costs and carbon emissions reductions. In this study, we calculated the hourly dynamic CO 2 signal and applied the calculation to hourly electricity market data in Great Britain, Ontario and Sweden. This provided a novel understanding of the relationships between hourly electricity generation mix composition, electricity price and electricity mix CO 2 intensity. Load shifts from high-price hours resulted in carbon emission reductions for electricity generation mixes where price and CO 2 intensity were positively correlated. The reduction can be further improved if the shift is optimised using both price and CO 2 intensity. The analysis also indicated that an hourly CO 2 intensity signal can help avoid carbon emissions increases for mixes with a negative correlation between electricity price and CO 2 intensity. - Highlights: • We present a formula for calculating hybrid dynamic CO 2 intensity of electricity generation mixes. • We apply the dynamic CO 2 Intensity on hourly electricity market prices and generation units for Great Britain, Ontario and Sweden. • We calculate the spearman correlation between hourly electricity market price and dynamic CO 2 intensity for Great Britain, Ontario and Sweden. • We calculate carbon footprint of shifting 1 kWh load daily from on-peak hours to off-peak hours using the dynamic CO 2 intensity. • We conclude that using dynamic CO 2 intensity for

  10. Correlation of non-mass-like abnormal MR signal intensity with pathological findings surrounding pediatric osteosarcoma and Ewing's sarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Masrouha, Karim Z.; Haidar, Rachid; Saghieh, Said [American University of Beirut Medical Center, Department of Surgery, Beirut (Lebanon); Musallam, Khaled M. [American University of Beirut Medical Center, Internal Medicine Division of Hematology and Oncology, Beirut (Lebanon); Samra, Alexis Bou; Tawil, Ayman; Chakhachiro, Zaher [American University of Beirut Medical Center, Pathology, Beirut (Lebanon); Abdallah, Abeer; Khoury, Nabil J. [American University of Beirut Medical Center, Diagnostic Radiology, Beirut (Lebanon); Saab, Raya; Muwakkit, Samar; Abboud, Miguel R. [American University of Beirut Medical Center, Children' s Cancer Center of Lebanon, Beirut (Lebanon)

    2012-11-15

    The aim of this work was to determine the role of MRI in interpreting abnormal signals within bones and soft tissues adjacent to tumor bulk of osteosarcoma and Ewing's sarcoma in a pediatric population by correlating MR findings with histopathology. Thirty patients met the inclusion criteria, which included (1) osteosarcoma or Ewing's sarcoma, (2) MR studies no more than 2 months prior to surgery, (3) presence of abnormal MR signal surrounding the tumor bulk, (4) pathological material from resected tumor. The patients received standard neoadjuvant chemotherapy. Using grid maps on gross pathology specimens, the abnormal MR areas around the tumor were matched with the corresponding grid sections. Histopathology slides of these sections were then analyzed to determine the nature of the regions of interest. The MR/pathological correlation was evaluated using Mann-Whitney U test and Fisher's exact test. Twenty-seven patients had osteosarcoma and three patients had Ewing's sarcoma. Of the studied areas, 17.4% were positive for tumor (viable or necrotic). There was no statistically significant correlation between areas positive for tumor and age, gender, signal extent and intensity on MRI, or tissue type. There was, however, a statistically significant correlation between presence of tumor and the appearance of abnormal soft tissue signals. A feathery appearance correlated with tumor-negative areas whereas a bulky appearance correlated with tumor-positive regions. MR imaging is helpful in identifying the nature of abnormal signal areas surrounding bone sarcomas that are more likely to be tumor-free, particularly when the signal in the soft tissues surrounding the tumor is feathery and edema-like in appearance. (orig.)

  11. The Standardized Histogram Shift of T2 Magnetic Resonance Image (MRI) Signal Intensities of Nephroblastoma Does Not Predict Histopathological Diagnostic Information

    OpenAIRE

    M?ller, Sabine; David, Ruslan; Marias, Kostas; Graf, Norbert

    2015-01-01

    The objective of this study is to assess standardized histograms of signal intensities of T2-weighted magnetic resonance image (MRI) modality before and after preoperative chemotherapy for nephroblastoma (Wilms? tumor). All analyzed patients are enrolled in the International Society of Paediatric Oncology (SIOP) 2001/GPOH trial.1 The question to be answered is whether the comparison of the histograms can add new knowledge by comparing them with the histology of the tumor after preoperative ch...

  12. Intensity-Curvature Measurement Approaches for the Diagnosis of Magnetic Resonance Imaging Brain Tumors

    Directory of Open Access Journals (Sweden)

    Carlo Ciulla

    2015-11-01

    Full Text Available This research presents signal-image post-processing techniques called Intensity-Curvature Measurement Approaches with application to the diagnosis of human brain tumors detected through Magnetic Resonance Imaging (MRI. Post-processing of the MRI of the human brain encompasses the following model functions: (i bivariate cubic polynomial, (ii bivariate cubic Lagrange polynomial, (iii monovariate sinc, and (iv bivariate linear. The following Intensity-Curvature Measurement Approaches were used: (i classic-curvature, (ii signal resilient to interpolation, (iii intensity-curvature measure and (iv intensity-curvature functional. The results revealed that the classic-curvature, the signal resilient to interpolation and the intensity-curvature functional are able to add additional information useful to the diagnosis carried out with MRI. The contribution to the MRI diagnosis of our study are: (i the enhanced gray level scale of the tumor mass and the well-behaved representation of the tumor provided through the signal resilient to interpolation, and (ii the visually perceptible third dimension perpendicular to the image plane provided through the classic-curvature and the intensity-curvature functional.

  13. T2 signal intensity as an imaging biomarker for patients with superficial Fibromatoses of the hands (Dupuytren's disease) and feet (Ledderhose disease) undergoing definitive electron beam irradiation.

    Science.gov (United States)

    Banks, James S; Wolfson, Aaron H; Subhawong, Ty K

    2018-02-01

    Electron beam therapy is a definitive radiation treatment option for superficial fibromatoses of the hands and feet. Because objective criteria for treatment response remain poorly defined, we sought to describe changes in electron beam treated lesions on MRI. The study included 1 male and 9 female patients with a total of 37 superficial fibromatoses; average age was 60.7 years. Standard 6 MeV electron beam treatment included 3 Gy per fraction for 10 or 12 treatments using split-course with 3-month halfway break. Pre- and post-treatment MRIs were evaluated to determine lesion size (cm3), T2 signal intensity and contrast enhancement (5-point ordinal scales) by a fellowship trained musculoskeletal radiologist. MRI findings were correlated with clinical response using a composite 1-5 ordinal scale, Karnofsky Performance Scale and patient-reported 10-point visual analog scale for pain. Mean volume decreased from 1.5 to 1.2 cm 3 (p = 0.01, paired t-test). Mean T2 hyperintensity score decreased from 3.0 to 2.1 (p Wilcoxon signed-rank). Mean enhancement score available for 22 lesions decreased from 3.8 to 3.0 (p Wilcoxon signed-rank). Performance scores improved from 78.9 ± 13.7 to 84.6 ± 6.9 (p = 0.007, paired t-test). Pain scores decreased from 3.0 ± 3.3 to 1.1 ± 2.0 (p = 0.0001, paired t-test). Post-treatment T2 signal correlated weakly with performance and pain (Spearman's ρ = -0.37 and 0.16, respectively). MRI is valuable for evaluating patients undergoing electron beam therapy for superficial fibromatoses: higher pretreatment T2 intensity may predict benefit from radiotherapy. T2 hypointensity may be a better marker than size for therapeutic effect.

  14. Intensive Mode Delivery of a Neuroanatomy Unit: Lower Final Grades but Higher Student Satisfaction

    Science.gov (United States)

    Whillier, Stephney; Lystad, Reidar P.

    2013-01-01

    In 2011, Macquarie University moved to a three-session academic year which included two 13-week sessions (traditional mode) and one seven-week session (intensive mode). This study was designed to compare the intensive and traditional modes of delivery in a unit of undergraduate neuroanatomy. The new intensive mode neuroanatomy unit provided the…

  15. Smoke Signal or Smoke Screen?

    DEFF Research Database (Denmark)

    Vergne, Jean-Philippe; Wernicke, Georg; Brenner, Steffen

    This paper explains the amount of disapproval faced by firms that overpay their CEO by integrating signaling and categorization theories. We argue that, in contexts characterized by intense scrutiny, ambivalent signals sent by firms suspend categorization by stakeholders, leading to further disap...

  16. Higher order spectra and their use in digital communication signal estimation

    Science.gov (United States)

    Yayci, Cihat

    1995-03-01

    This thesis compared the detection ability of the spectrogram, the 1-1/2D instantaneous power spectrum (l-1/2D(sub ips)), the bispectrum, and outer product (dyadic) representation for digitally modulated signals corrupted by additive white Gaussian noise. Four detection schemes were tried on noise free BPSK, QPSK, FSK, and OOK signals using different transform lengths. After determining the optimum transform length, each test signal is corrupted by additive white Gaussian noise. Different SNR levels were used to determine the lowest SNR level at which the message or the modulation type could be extracted. The optimal transform length was found to be the symbol duration when processing BPSK, OOK, and FSK via the spectrogram, the 1-1/2D(sub ips) or the bispectrum method. The best transform size for QPSK was half of the symbol length. For the outer product (dyadic) spectral representation, the best transform size was four times larger than the symbol length. For all processing techniques, with the exception of the other product representation, the minimum detectable SNR is about 15 dB for BPSK, FSK, and OOK signals and about 20 dB for QPSK signals. For the outer product spectral method, these values tend to be about 10 dB lower.

  17. Comparison of higher-order multiphoton signal generation and collection at the 1700-nm window based on transmittance measurement of objective lenses.

    Science.gov (United States)

    Wen, Wenhui; Wang, Yuxin; Liu, Hongji; Wang, Kai; Qiu, Ping; Wang, Ke

    2018-01-01

    One benefit of excitation at the 1700-nm window is the more accessible modalities of multiphoton signal generation. It is demonstrated here that the transmittance performance of the objective lens is of vital importance for efficient higher-order multiphoton signal generation and collection excited at the 1700-nm window. Two commonly used objective lenses for multiphoton microscopy (MPM) are characterized and compared, one with regular coating and the other with customized coating for high transmittance at the 1700-nm window. Our results show that, fourth harmonic generation imaging of mouse tail tendon and 5-photon fluorescence of carbon quantum dots using the regular objective lens shows an order of magnitude signal higher than those using the customized objective lens. Besides, the regular objective lens also enables a 3-photon fluorescence imaging depth of >1600 μm in mouse brain in vivo. Our results will provide guidelines for objective lens selection for MPM at the 1700-nm window. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Linear signal processing using silicon micro-ring resonators

    DEFF Research Database (Denmark)

    Peucheret, Christophe; Ding, Yunhong; Ou, Haiyan

    2012-01-01

    We review our recent achievements on the use of silicon micro-ring resonators for linear optical signal processing applications, including modulation format conversion, phase-to-intensity modulation conversion and waveform shaping.......We review our recent achievements on the use of silicon micro-ring resonators for linear optical signal processing applications, including modulation format conversion, phase-to-intensity modulation conversion and waveform shaping....

  19. Evaluation of diffuse diseases of the upper abdominal organs by MRI. Determination of a normal range in signal intensity ratio of each organ to the renal medulla in T1- and T2-weighted images and evaluation of diffuse diseases of an organ by using it

    International Nuclear Information System (INIS)

    Mitsuhashi, Hiroshi

    1995-01-01

    Diffuse diseases of the upper abdominal organs, including the liver, spleen, pancreas, and vertebral marrow, were evaluated by using signal intensity ratio of each organ to the renal medulla in T1- and T2-weighted images. Conventional T1- and T2-weighted images were obtained in 1.5 T MR system in 203 persons, including 122 controls and 81 patients with a diffuse disease in the upper abdominal organ. In controls, though there was neither sexual nor age difference in signal intensity ratios of the liver and pancreas, those of the spleen and vertebral marrow showed sexual and age difference, respectively. A normal range of signal intensity ratio of each organ in each image was determined in each decade of each sex by using controls. The signal intensity ratio of the liver was significantly low in T1- and T2-weighted images in patients with abundant iron deposit and within normal limits in patients with liver cirrhosis or scant iron deposit. The signal intensity ratio of the liver was significantly high only in a T2-weighted image in patients with fatty deposit in the liver, which was suspected to be due to inflammatory change in the liver with fatty deposit. The signal intensity ratios of the spleen, pancreas, and vertebral marrow were significantly low only in a T2-weighted image in patients with iron metabolic disturbance. The signal intensity ratio of the pancreas was significantly high in 40% of patients with acute and/or chronic pancreatitis, which was more sensitive in detection of pancreatitis than data in other studies. it can be concluded that the signal intensity ratio of each organ to the renal medulla in T1- and T2-weighted images is useful for detection of diffuse diseases of the upper abdominal organs by using the normal range in each decade of each sex. (S.Y.)

  20. Monitoring of transient cavitation induced by ultrasound and intense pulsed light in presence of gold nanoparticles.

    Science.gov (United States)

    Sazgarnia, Ameneh; Shanei, Ahmad; Shanei, Mohammad Mahdi

    2014-01-01

    One of the most important challenges in medical treatment is invention of a minimally invasive approach in order to induce lethal damages to cancer cells. Application of high intensity focused ultrasound can be beneficial to achieve this goal via the cavitation process. Existence of the particles and vapor in a liquid decreases the ultrasonic intensity threshold required for cavitation onset. In this study, synergism of intense pulsed light (IPL) and gold nanoparticles (GNPs) has been investigated as a means of providing nucleation sites for acoustic cavitation. Several approaches have been reported with the aim of cavitation monitoring. We conducted the experiments on the basis of sonochemiluminescence (SCL) and chemical dosimetric methods. The acoustic cavitation activity was investigated by determining the integrated SCL signal acquired over polyacrylamide gel phantoms containing luminol in the presence and absence of GNPs in the wavelength range of 400-500 nm using a spectrometer equipped with cooled charged coupled devices (CCD) during irradiation by different intensities of 1 MHz ultrasound and IPL pulses. In order to confirm these results, the terephthalic acid chemical dosimeter was utilized as well. The SCL signal recorded in the gel phantoms containing GNPs at different intensities of ultrasound in the presence of intense pulsed light was higher than the gel phantoms without GNPs. These results have been confirmed by the obtained data from the chemical dosimetry method. Acoustic cavitation in the presence of GNPs and intense pulsed light has been suggested as a new approach designed for decreasing threshold intensity of acoustic cavitation and improving targeted therapeutic effects. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Diffusion-weighted magnetic resonance imaging for the initial characterization of non-fatty soft tissue tumors: correlation between T2 signal intensity and ADC values

    Energy Technology Data Exchange (ETDEWEB)

    Gondim Teixeira, Pedro Augusto [Service d' Imagerie Guilloz, CHU Nancy, Nancy (France); Universite de Lorraine, IADI, UMR S 947, Vandoeuvre-les-Nancy (France); Gay, Frederique; Blum, Alain [Service d' Imagerie Guilloz, CHU Nancy, Nancy (France); Chen, Bailiang; Felblinger, Jacques [Universite de Lorraine, IADI, UMR S 947, Vandoeuvre-les-Nancy (France); Zins, Marie [University Versailles St-Quentin, Versailles (France); Inserm, Centre for research in Epidemiology and Population Health (CESP), U1018, Villejuif (France); Sirveaux, Francois [Centre Chirurgical Emile Galle, Service de Chirurgie Traumatologique et Orthopedique, Nancy (France)

    2016-02-15

    To evaluate the performance of quantitative diffusion-weighted imaging (DWI) correlated with T2 signal in differentiating non-fatty benign from malignant tumors. A total of 76 patients with a histologically confirmed non-fatty soft tissue tumors (46 benign and 30 malignant) were prospectively included in this ethics committee approved study. All patients signed an informed consent and underwent MRI with DWI with two b values (0 and 600). ADC values from the solid components of these tumors were obtained and were correlated with the lesion's signal intensity on T2-weighted fat-saturated sequences. ADC values were obtained from adjacent normal muscle to allow calculation of tumor/muscle ADC ratios. There were 58 hyperintense and 18 iso or hypointense lesions. All hypointense lesions were benign. The mean ADC values for benign and malignant tumors were 1.47 ± 0.54 x 10{sup -3} and 1.17 ± 0.38 x 10{sup -3} mm{sup 2}/s respectively (p < 0.005). The mean ADC ratio in benign iso or hypointense tumors was significantly lower than that of hyperintense ones (0.76 ± 0.21 versus 1.58 ± 0.82 - p < 0.0001). An ADC ratio lower than 0.915 was highly specific for malignancy (96.4 %), whereas an ADC ratio higher than 1.32 was highly sensitive for benign lesions (90 %). ADC analysis can be useful in the initial characterization of T2 hyperintense non-fatty soft tissue masses, although this technique alone is not likely to change patient management. (orig.)

  2. Integrated intensities in inverse time-of-flight technique

    International Nuclear Information System (INIS)

    Dorner, Bruno

    2006-01-01

    In traditional data analysis a model function, convoluted with the resolution, is fitted to the measured data. In case that integrated intensities of signals are of main interest, one can use an approach which does not require a model function for the signal nor detailed knowledge of the resolution. For inverse TOF technique, this approach consists of two steps: (i) Normalisation of the measured spectrum with the help of a monitor, with 1/k sensitivity, which is positioned in front of the sample. This means at the same time a conversion of the data from time of flight to energy transfer. (ii) A Jacobian [I. Waller, P.O. Froeman, Ark. Phys. 4 (1952) 183] transforms data collected at constant scattering angle into data as if measured at constant momentum transfer Q. This Jacobian works correctly for signals which have a constant width at different Q along the trajectory of constant scattering angle. The approach has been tested on spectra of Compton scattering with neutrons, having epithermal energies, obtained on the inverse TOF spectrometer VESUVIO/ISIS. In this case the width of the signal is increasing proportional to Q and in consequence the application of the Jacobian leads to integrated intensities slightly too high. The resulting integrated intensities agree very well with results derived in the traditional way. Thus this completely different approach confirms the observation that signals from recoil by H-atoms at large momentum transfers are weaker than expected

  3. Development of a rapid and sensitive LC-ESI/MS/MS assay for the quantification of propofol using a simple off-line dansyl chloride derivatization reaction to enhance signal intensity.

    Science.gov (United States)

    Beaudry, Francis; Guénette, Sarah Annie; Winterborn, Andrew; Marier, Jean-Francois; Vachon, Pascal

    2005-09-15

    A rapid, selective and sensitive method was developed for the determination of propofol concentration using an off-line dansyl chloride derivatization step to enhance signal intensity. The method consisted of a protein precipitation extraction followed by derivatization with dansyl chloride and analysis by liquid chromatography ionspray tandem mass spectrometry (LC-ESI/MS/MS). The separation was achieved using a 100 mm x 2 mm C8 analytical column combined with an isocratic mobile phase composed of 80:20 acetonitrile: 0.5% formic acid in water. Signal intensity of the propofol-dansyl chloride derivative was increased up to 200-fold as compared to the underivatized propofol in positive electrospray mode. An analytical range of 20-20,000 ng/mL was used in the calibration curve of plasma and blood samples. The novel method met all requirements of specificity, sensitivity, linearity, precision, accuracy and stability. A pharmacokinetic study was performed in rats and the novel analytical method was used as a routine analysis to provide enhanced measurements of plasma and blood concentrations of propofol. Blood and plasma pharmacokinetic results show that a very important fraction of propofol distributes into red blood cells. In conclusion, a rapid and sensitive LC-ESI/MS/MS method using a derivatization agent was developed to enhance signal intensity of propofol. Routine analysis with the novel method provided accurate results and enhanced the detection levels of plasma and blood concentrations of propofol to better characterize the in vivo biodisposition of propofol.

  4. Improving the signal-to-noise ratio in ultrasound-modulated optical tomography by a lock-in amplifier

    Science.gov (United States)

    Zhu, Lili; Wu, Jingping; Lin, Guimin; Hu, Liangjun; Li, Hui

    2016-10-01

    With high spatial resolution of ultrasonic location and high sensitivity of optical detection, ultrasound-modulated optical tomography (UOT) is a promising noninvasive biological tissue imaging technology. In biological tissue, the ultrasound-modulated light signals are very weak and are overwhelmed by the strong unmodulated light signals. It is a difficulty and key to efficiently pick out the weak modulated light from strong unmodulated light in UOT. Under the effect of an ultrasonic field, the scattering light intensity presents a periodic variation as the ultrasonic frequency changes. So the modulated light signals would be escape from the high unmodulated light signals, when the modulated light signals and the ultrasonic signal are processed cross correlation operation by a lock-in amplifier and without a chopper. Experimental results indicated that the signal-to-noise ratio of UOT is significantly improved by a lock-in amplifier, and the higher the repetition frequency of pulsed ultrasonic wave, the better the signal-to-noise ratio of UOT.

  5. T2 signal intensity as an imaging biomarker for patients with superficial fibromatoses of the hands (Dupuytren's disease) and feet (Ledderhose disease) undergoing definitive electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Banks, James S.; Subhawong, Ty K. [University of Miami Miller School of Medicine/Jackson Memorial Hospital, Department of Radiology, Miami, FL (United States); Wolfson, Aaron H. [University of Miami Miller School of Medicine, Sylvester Comprehensive Cancer Center, Department of Radiation Oncology, Miami, FL (United States)

    2018-02-15

    Electron beam therapy is a definitive radiation treatment option for superficial fibromatoses of the hands and feet. Because objective criteria for treatment response remain poorly defined, we sought to describe changes in electron beam treated lesions on MRI. The study included 1 male and 9 female patients with a total of 37 superficial fibromatoses; average age was 60.7 years. Standard 6 MeV electron beam treatment included 3 Gy per fraction for 10 or 12 treatments using split-course with 3-month halfway break. Pre- and post-treatment MRIs were evaluated to determine lesion size (cm3), T2 signal intensity and contrast enhancement (5-point ordinal scales) by a fellowship trained musculoskeletal radiologist. MRI findings were correlated with clinical response using a composite 1-5 ordinal scale, Karnofsky Performance Scale and patient-reported 10-point visual analog scale for pain. Mean volume decreased from 1.5 to 1.2 cm{sup 3} (p = 0.01, paired t-test). Mean T2 hyperintensity score decreased from 3.0 to 2.1 (p < 0.0001, Wilcoxon signed-rank). Mean enhancement score available for 22 lesions decreased from 3.8 to 3.0 (p < 0.0001, Wilcoxon signed-rank). Performance scores improved from 78.9 ± 13.7 to 84.6 ± 6.9 (p = 0.007, paired t-test). Pain scores decreased from 3.0 ± 3.3 to 1.1 ± 2.0 (p = 0.0001, paired t-test). Post-treatment T2 signal correlated weakly with performance and pain (Spearman's ρ = -0.37 and 0.16, respectively). MRI is valuable for evaluating patients undergoing electron beam therapy for superficial fibromatoses: higher pretreatment T2 intensity may predict benefit from radiotherapy. T2 hypointensity may be a better marker than size for therapeutic effect. (orig.)

  6. T2 signal intensity as an imaging biomarker for patients with superficial fibromatoses of the hands (Dupuytren's disease) and feet (Ledderhose disease) undergoing definitive electron beam irradiation

    International Nuclear Information System (INIS)

    Banks, James S.; Subhawong, Ty K.; Wolfson, Aaron H.

    2018-01-01

    Electron beam therapy is a definitive radiation treatment option for superficial fibromatoses of the hands and feet. Because objective criteria for treatment response remain poorly defined, we sought to describe changes in electron beam treated lesions on MRI. The study included 1 male and 9 female patients with a total of 37 superficial fibromatoses; average age was 60.7 years. Standard 6 MeV electron beam treatment included 3 Gy per fraction for 10 or 12 treatments using split-course with 3-month halfway break. Pre- and post-treatment MRIs were evaluated to determine lesion size (cm3), T2 signal intensity and contrast enhancement (5-point ordinal scales) by a fellowship trained musculoskeletal radiologist. MRI findings were correlated with clinical response using a composite 1-5 ordinal scale, Karnofsky Performance Scale and patient-reported 10-point visual analog scale for pain. Mean volume decreased from 1.5 to 1.2 cm 3 (p = 0.01, paired t-test). Mean T2 hyperintensity score decreased from 3.0 to 2.1 (p < 0.0001, Wilcoxon signed-rank). Mean enhancement score available for 22 lesions decreased from 3.8 to 3.0 (p < 0.0001, Wilcoxon signed-rank). Performance scores improved from 78.9 ± 13.7 to 84.6 ± 6.9 (p = 0.007, paired t-test). Pain scores decreased from 3.0 ± 3.3 to 1.1 ± 2.0 (p = 0.0001, paired t-test). Post-treatment T2 signal correlated weakly with performance and pain (Spearman's ρ = -0.37 and 0.16, respectively). MRI is valuable for evaluating patients undergoing electron beam therapy for superficial fibromatoses: higher pretreatment T2 intensity may predict benefit from radiotherapy. T2 hypointensity may be a better marker than size for therapeutic effect. (orig.)

  7. Benign compression fractures of the spine: signal patterns

    International Nuclear Information System (INIS)

    Ryu, Kyung Nam; Choi, Woo Suk; Lee, Sun Wha; Lim, Jae Hoon

    1992-01-01

    Fifteen patients with 38 compression fractures of the spine underwent magnetic resonance(MR) imaging. We retrospectively evaluated MR images in those benign compression fractures. MR images showed four patterns in T1-weighted images. MR imaging patterns were normal signal(21), band like low signal(8), low signal with preservation of peripheral portion of the body(8), and diffuse low signal through the vertebral body(1). The low signal portions were changed to high signal intensities in T2-weighted images. In 7 of 15 patients (11 compression fractures), there was a history of trauma, and the remaining 8 patients (27 compression fractures) had no history of trauma. Benign compression fractures of trauma, remained 8 patients (27 compression fractures) were non-traumatic. Benign compression fractures of the spine reveal variable signal intensities in MR imagings. These patterns of benign compression fractures may be useful in interpretation of MR imagings of the spine

  8. Quantitative measurement of intervertebral disc signal using MRI

    International Nuclear Information System (INIS)

    Niemelaeinen, R.; Videman, T.; Dhillon, S.S.; Battie, M.C.

    2008-01-01

    Aim: To investigate the spinal cord as an alternative intra-body reference to cerebrospinal fluid (CSF) in evaluating thoracic disc signal intensity. Materials and methods: T2-weighted magnetic resonance imaging (MRI) images of T6-T12 were obtained using 1.5 T machines for a population-based sample of 523 men aged 35-70 years. Quantitative data on the signal intensities were acquired using an image analysis program (SpEx (copy right) ). A random sample of 30 subjects and intraclass correlation coeffcients (ICC) were used to examine the repeatability of the spinal cord measurements. The validity of using the spinal cord as a reference was examined by correlating cord and CSF samples. Finally, thoracic disc signal was validated by correlating it with age without adjustment and adjusting for either cord or CSF. Pearson's r was used for correlational analyses. Results: The repeatability of the spinal cord signal measurements was extremely high (≥0.99). The correlations between the signals of spinal cord and CSF by level were all above 0.9. The spinal cord-adjusted disc signal and age correlated similarly with CSF-adjusted disc signal and age (r = -0.30 to -0.40 versus r = -0.26 to -0.36). Conclusion: Adjacent spinal cord is a good alternative reference to the current reference standard, CSF, for quantitative measurements of disc signal intensity. Clearly fewer levels were excluded when using spinal cord as compared to CSF due to missing reference samples

  9. Quantitative measurement of intervertebral disc signal using MRI

    Energy Technology Data Exchange (ETDEWEB)

    Niemelaeinen, R. [Faculty of Rehabilitation Medicine, University of Alberta, Edmonton (Canada)], E-mail: riikka.niemelainen@ualberta.ca; Videman, T. [Faculty of Rehabilitation Medicine, University of Alberta, Edmonton (Canada); Dhillon, S.S. [Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton (Canada); Battie, M.C. [Faculty of Rehabilitation Medicine, University of Alberta, Edmonton (Canada)

    2008-03-15

    Aim: To investigate the spinal cord as an alternative intra-body reference to cerebrospinal fluid (CSF) in evaluating thoracic disc signal intensity. Materials and methods: T2-weighted magnetic resonance imaging (MRI) images of T6-T12 were obtained using 1.5 T machines for a population-based sample of 523 men aged 35-70 years. Quantitative data on the signal intensities were acquired using an image analysis program (SpEx (copy right) ). A random sample of 30 subjects and intraclass correlation coeffcients (ICC) were used to examine the repeatability of the spinal cord measurements. The validity of using the spinal cord as a reference was examined by correlating cord and CSF samples. Finally, thoracic disc signal was validated by correlating it with age without adjustment and adjusting for either cord or CSF. Pearson's r was used for correlational analyses. Results: The repeatability of the spinal cord signal measurements was extremely high ({>=}0.99). The correlations between the signals of spinal cord and CSF by level were all above 0.9. The spinal cord-adjusted disc signal and age correlated similarly with CSF-adjusted disc signal and age (r = -0.30 to -0.40 versus r = -0.26 to -0.36). Conclusion: Adjacent spinal cord is a good alternative reference to the current reference standard, CSF, for quantitative measurements of disc signal intensity. Clearly fewer levels were excluded when using spinal cord as compared to CSF due to missing reference samples.

  10. Radio Science from an Optical Communications Signal

    Science.gov (United States)

    Moision, Bruce; Asmar, Sami; Oudrhiri, Kamal

    2013-01-01

    NASA is currently developing the capability to deploy deep space optical communications links. This creates the opportunity to utilize the optical link to obtain range, doppler, and signal intensity estimates. These may, in turn, be used to complement or extend the capabilities of current radio science. In this paper we illustrate the achievable precision in estimating range, doppler, and received signal intensity of an non-coherent optical link (the current state-of-the-art for a deep-space link). We provide a joint estimation algorithm with performance close to the bound. We draw comparisons to estimates based on a coherent radio frequency signal, illustrating that large gains in either precision or observation time are possible with an optical link.

  11. Signalling crosstalk in plants: emerging issues.

    Science.gov (United States)

    Taylor, Jane E; McAinsh, Martin R

    2004-01-01

    The Oxford English Dictionary defines crosstalk as 'unwanted transfer of signals between communication channels'. How does this definition relate to the way in which we view the organization and function of signalling pathways? Recent advances in the field of plant signalling have challenged the traditional view of a signalling transduction cascade as isolated linear pathways. Instead the picture emerging of the mechanisms by which plants transduce environmental signals is of the interaction between transduction chains. The manner in which these interactions occur (and indeed whether the transfer of these signals is 'unwanted' or beneficial) is currently the topic of intense research.

  12. Reduction of emission level in approach signals of greater mouse-eared bats (Myotis myotis): No evidence for a closed loop control system for intensity compensation.

    Science.gov (United States)

    Budenz, Tobias; Denzinger, Annette; Schnitzler, Hans-Ulrich

    2018-01-01

    Bats lower the emission SPL when approaching a target. The SPL reduction has been explained by intensity compensation which implies that bats adjust the emission SPL to perceive the retuning echoes at the same level. For a better understanding of this control mechanism we recorded the echolocation signals of four Myotis myotis with an onboard microphone when foraging in the passive mode for rustling mealworms offered in two feeding dishes with different target strength, and determined the reduction rate for the emission SPL and the increase rate for the SPL of the returning echoes. When approaching the dish with higher target strength bats started the reduction of the emission SPL at a larger reaction distance (1.05 ± 0.21 m) and approached it with a lower reduction rate of 7.2 dB/halving of distance (hd), thus producing a change of echo rate at the ears of + 4 dB/hd. At the weaker target reaction distance was shorter (0.71 ± 0.24 m) and the reduction rate (9.1 dB/hd) was higher, producing a change of echo rate of-1.2 dB/hd. Independent of dish type, bats lowered the emission SPL by about 26 dB on average. In one bat where the echo SPL from both targets could be measured, the reduction of emission SPL was triggered when the echo SPL surpassed a similar threshold value around 41-42 dB. Echo SPL was not adjusted at a constant value indicating that Myotis myotis and most likely all other bats do not use a closed loop system for intensity compensation when approaching a target of interest. We propose that bats lower the emission SPL to adjust the SPL of the perceived pulse-echo-pairs to the optimal auditory range for the processing of range information and hypothesize that bats use flow field information not only to control the reduction of the approach speed to the target but also to control the reduction of emission SPL.

  13. Dietary pattern associated with selenoprotein P and MRI-derived body fat volumes, liver signal intensity, and metabolic disorders.

    Science.gov (United States)

    di Giuseppe, Romina; Plachta-Danielzik, Sandra; Koch, Manja; Nöthlings, Ute; Schlesinger, Sabrina; Borggrefe, Jan; Both, Marcus; Müller, Hans-Peter; Kassubek, Jan; Jacobs, Gunnar; Lieb, Wolfgang

    2018-02-14

    The association of complex dietary patterns with circulating selenoprotein P (SELENOP) levels in humans is unknown. In a general population sample, we aimed to identify a dietary pattern explaining inter-individual variation in circulating SELENOP concentrations and to study this pattern in relation to prevalent diabetes, metabolic syndrome (MetS), MRI-determined total volumes of visceral (VAT) and subcutaneous (SAT) abdominal adipose tissue, and liver signal intensity/fatty liver disease. In this cross-sectional study, serum SELENOP levels were measured in 853 individuals. In a subsample of 553 participants, whole-body MRI was performed to assess body fat distribution and liver fat. Dietary intake was assessed by a self-administered food frequency questionnaire and the dietary pattern identified using reduced-rank regression (RRR). Multivariable linear and logistic regressions were used to investigate associations between dietary pattern score and metabolic traits. Characterized by high intake of fruit, vegetables and antioxidant beverages, the RRR-derived dietary pattern displayed inverse associations with VAT, SAT, MetS, and prevalent diabetes in multivariable-adjusted restricted cubic splines. Each unit increase in dietary pattern score was associated with 31% higher SELENOP levels, 12% lower VAT (95% CI: - 19%; - 5%), 13% (95% CI: - 20%; - 6%) lower SAT values and 46% (95% CI: 27%; 60%) and 53% (95% CI: 22%; 72%) lower odds of having MetS or diabetes, respectively. No meaningful relations were observed between the dietary pattern and liver traits. Our observations propose diet-related regulation in SELENOP levels and that the identified dietary pattern is inversely related to VAT, SAT, MetS, and prevalent diabetes.

  14. Estimation of gadolinium-induced T1-shortening with measurement of simple signal intensity ratio between the cochlea and brain parenchyma on 3D-FLAIR. Correlation with T1 measurement by TI scout sequence

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Ishihara, Shunichi; Iwano, Shingo; Kawai, Hisashi; Sone, Michihiko; Nakashima, Tsutomu

    2010-01-01

    The purpose of this study was to T 1 -shortening of labyrinthine fluid on 3-dimensional fluid-attenuated inversion recovery (3D-FLAIR) has been reported in many inner ear disorders. Although semi-quantitative assessment by simple signal intensity ratio between cochlear fluid and brain tissue has been tried, its feasibility using a multi-channel phased-array head coil with an inherently inhomogenous sensitivity distribution has not been fully evaluated. We evaluated the feasibility of measuring simple signal intensity ratio by correlating rapid T 1 measurements using an inversion time (TI) scout sequence. We evaluated 10 patients with Meniere's disease and 4 patients with sudden deafness. Nine of the patients with Meniere's disease received a unilateral intratympanic injection of gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA); the tenth patient received bilateral injections. The 4 patients with sudden deafness received a double-dose intravenous injection. Magnetic resonance (MR) images were obtained 24 hours after intratympanic injections and 4 hours after intravenous injections at 3 tesla using a 32-channel head coil. We measured the ratio (CM ratio) between the signal intensity of the perilymph in the cochlea (C) and that of the medulla oblongata (M) and correlated it with the null-point inversion time (TI null ) obtained with the TI scout sequence. The TI scout consisted of 85 images obtained with TI values between 132.5 and 3087.5 ms at increments of 37.5 ms. The correlation coefficient between TI null and the natural logarithm of the CM ratio was -0.88 (P<0.01). There was significant negative linear correlation. Measurement of the simple signal intensity ratio between the cochlea and the medulla can be used for semi-quantitative analysis of 3D-FLAIR. The results of this study may facilitate clinical research of inner-ear disease using 3D-FLAIR. (author)

  15. Challenges in higher order mode Raman amplifiers

    DEFF Research Database (Denmark)

    Rottwitt, Karsten; Nielsen, Kristian; Friis, Søren Michael Mørk

    2015-01-01

    A higher order Raman amplifier model that take random mode coupling into account ispresented. Mode dependent gain and signal power fluctuations at the output of the higher order modeRaman amplifier are discussed......A higher order Raman amplifier model that take random mode coupling into account ispresented. Mode dependent gain and signal power fluctuations at the output of the higher order modeRaman amplifier are discussed...

  16. Task-related signal decrease on functional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hara, Yoshie; Nakamura, Mitsugu; Tamaki, Norihiko; Tamura, Shogo; Kitamura, Junji

    2001-01-01

    An atypical pattern of signal change was identified on functional magnetic resonance (fMR) imaging in pathologic patients. Three normal volunteers and 34 patients with pathologic lesions near the primary motor cortex underwent fMR imaging with echo-planar imaging while performing a hand motor task. Signal intensities were evaluated with the z-score method, and the time course and changes of the signal intensity were calculated. Nine of the 34 patients with pathologic lesions displayed a significant task-related signal reduction in motor-related areas. They also presented a conventional task-related signal increase in other motor-related areas. The time courses of the increase and decrease were the inverse of each other. There was no significant difference between rates of signal increase and decrease. Our findings suggest that this atypical signal decrease is clinically significant, and that impaired vascular reactivity and altered oxygen metabolism could contribute to the task-related signal reduction. Brain areas showing such task-related signal decrease should be preserved at surgery. (author)

  17. Hepatocellular carcinoma: clinical significance of signal heterogeneity in the hepatobiliary phase of gadoxetic acid-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Nobuhiro; Nishie, Akihiro; Asayama, Yoshiki; Ushijima, Yasuhiro; Moirta, Koichiro; Honda, Hiroshi [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Kubo, Yuichiro; Aishima, Shinichi [Kyushu University, Department of Anatomic Pathology, Graduate School of Medical Sciences, Fukuoka (Japan); Takayama, Yukihisa [Kyushu University, Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Fukuoka (Japan); Shirabe, Ken [Kyushu University, Department of Surgery and Science, Graduate School of Medical Sciences, Fukuoka (Japan)

    2015-01-15

    To clarify the relationship between the biological behaviour of hepatocellular carcinomas (HCCs) and their signal intensity in the hepatobiliary phase of gadoxetic acid-enhanced MR imaging with a special focus on the signal heterogeneity. A total of 68 patients with 70 pathologically proven HCCs were enrolled. On the basis of the signal intensity in the hepatobiliary phase, the lesions were classified into three groups: group 1, homogeneous hypointensity (n = 44); group 2, heterogeneous hyperintensity (n = 20); and group 3, homogeneous hyperintensity (n = 6). The clinicopathological findings were compared among the three groups. The tumour size and the serum level of protein induced by vitamin K absence or antagonist-II (PIVKA-II) were significantly higher in group 2 compared to group 1 (p = 0.0155, p = 0.0215, respectively) and compared to group 3 (p = 0.0330, p = 0.0220, respectively). The organic anion transporting polypeptide 8 (OATP8) expression in group 2 and group 3 was significantly higher than in group 1 (p < 0.0001, p < 0.0001, respectively). Group 2 showed a significantly lower disease-free survival rate compared to group 1 (p = 0.0125), and group 2 was an independent prognostic factor for disease-free survival (p = 0.0308). HCCs in the hepatobiliary phase that are heterogeneously hyperintense on gadoxetic acid-enhanced MR imaging have more malignant potential than other types of HCCs. (orig.)

  18. Abnormalities of hippocampal signal intensity in patients with familial mesial temporal lobe epilepsy

    Directory of Open Access Journals (Sweden)

    Coan A.C.

    2004-01-01

    Full Text Available Mesial temporal lobe epilepsy (MTLE is associated with hippocampal atrophy and hippocampal signal abnormalities. In our series of familial MTLE (FMTLE, we found a high proportion of hippocampal abnormalities. To quantify signal abnormalities in patients with FMTLE we studied 152 individuals (46 of them asymptomatic with FMTLE. We used NIH-Image® for volumetry and signal quantification in coronal T1 inversion recovery and T2 for all cross-sections of the hippocampus. Values diverging by 2 or more SD from the control mean were considered abnormal. T2 hippocampal signal abnormalities were found in 52% of all individuals: 54% of affected subjects and 48% of asymptomatic subjects. T1 hippocampal signal changes were found in 34% of all individuals: 42.5% of affected subjects and 15% of asymptomatic subjects. Analysis of the hippocampal head (first three slices revealed T2 abnormalities in 73% of all individuals (74% of affected subjects and 72% of asymptomatic subjects and T1 abnormalities in 59% (67% of affected subjects and 41% of asymptomatic subjects. Affected individuals had smaller volumes than controls (P < 0.0001. There was no difference in hippocampal volumes between asymptomatic subjects and controls, although 39% of asymptomatic patients had hippocampal atrophy. Patients with an abnormal hippocampal signal (133 individuals had smaller ipsilateral volume, but no linear correlation could be determined. Hippocampal signal abnormalities in FMTLE were more frequently found in the hippocampal head in both affected and asymptomatic family members, including those with normal volumes. These results indicate that subtle abnormalities leading to an abnormal hippocampal signal in FMTLE are not necessarily related to seizures and may be determined by genetic factors.

  19. Adaptive plasticity in wild field cricket's acoustic signaling.

    Directory of Open Access Journals (Sweden)

    Susan M Bertram

    Full Text Available Phenotypic plasticity can be adaptive when phenotypes are closely matched to changes in the environment. In crickets, rhythmic fluctuations in the biotic and abiotic environment regularly result in diel rhythms in density of sexually active individuals. Given that density strongly influences the intensity of sexual selection, we asked whether crickets exhibit plasticity in signaling behavior that aligns with these rhythmic fluctuations in the socio-sexual environment. We quantified the acoustic mate signaling behavior of wild-caught males of two cricket species, Gryllus veletis and G. pennsylvanicus. Crickets exhibited phenotypically plastic mate signaling behavior, with most males signaling more often and more attractively during the times of day when mating activity is highest in the wild. Most male G. pennsylvanicus chirped more often and louder, with shorter interpulse durations, pulse periods, chirp durations, and interchirp durations, and at slightly higher carrier frequencies during the time of the day that mating activity is highest in the wild. Similarly, most male G. veletis chirped more often, with more pulses per chirp, longer interpulse durations, pulse periods, and chirp durations, shorter interchirp durations, and at lower carrier frequencies during the time of peak mating activity in the wild. Among-male variation in signaling plasticity was high, with some males signaling in an apparently maladaptive manner. Body size explained some of the among-male variation in G. pennsylvanicus plasticity but not G. veletis plasticity. Overall, our findings suggest that crickets exhibit phenotypically plastic mate attraction signals that closely match the fluctuating socio-sexual context they experience.

  20. Implementation of the Electronics Chain for the Bunch by Bunch Intensity Measurement Devices for the LHC

    CERN Document Server

    Belohrad, D; Ludwig, M; Savioz, J J; Thoulet, S

    2009-01-01

    The fast beam intensity measurements for the LHC are provided by eight Fast Beam Current Transformers (FBCT). Four FBCTs installed in the LHC rings are capable of providing both bunch-by-bunch and total turn-by-turn beam intensity information. A further four FBCTs, two in each of the LHC dump lines, are used to measure the total extracted beam intensity. In addition to providing intensity information the ring FBCTs also send signals to the machine protection system. This increases the complexity of both the RF front-end and the digital acquisition parts of the signal processing chain. The aim of this paper is to discuss the implemented hardware solution for the FBCT system, in particular with respect to the signal distribution, FPGA signal processing, calibration, and interaction of the FBCTs with the machine protection chain.

  1. Intensity earthquake scenario (scenario event - a damaging earthquake with higher probability of occurrence) for the city of Sofia

    Science.gov (United States)

    Aleksandrova, Irena; Simeonova, Stela; Solakov, Dimcho; Popova, Maria

    2014-05-01

    Among the many kinds of natural and man-made disasters, earthquakes dominate with regard to their social and economical impact on the urban environment. Global seismic risk to earthquakes are increasing steadily as urbanization and development occupy more areas that a prone to effects of strong earthquakes. Additionally, the uncontrolled growth of mega cities in highly seismic areas around the world is often associated with the construction of seismically unsafe buildings and infrastructures, and undertaken with an insufficient knowledge of the regional seismicity peculiarities and seismic hazard. The assessment of seismic hazard and generation of earthquake scenarios is the first link in the prevention chain and the first step in the evaluation of the seismic risk. The earthquake scenarios are intended as a basic input for developing detailed earthquake damage scenarios for the cities and can be used in earthquake-safe town and infrastructure planning. The city of Sofia is the capital of Bulgaria. It is situated in the centre of the Sofia area that is the most populated (the population is of more than 1.2 mil. inhabitants), industrial and cultural region of Bulgaria that faces considerable earthquake risk. The available historical documents prove the occurrence of destructive earthquakes during the 15th-18th centuries in the Sofia zone. In 19th century the city of Sofia has experienced two strong earthquakes: the 1818 earthquake with epicentral intensity I0=8-9 MSK and the 1858 earthquake with I0=9-10 MSK. During the 20th century the strongest event occurred in the vicinity of the city of Sofia is the 1917 earthquake with MS=5.3 (I0=7-8 MSK). Almost a century later (95 years) an earthquake of moment magnitude 5.6 (I0=7-8 MSK) hit the city of Sofia, on May 22nd, 2012. In the present study as a deterministic scenario event is considered a damaging earthquake with higher probability of occurrence that could affect the city with intensity less than or equal to VIII

  2. Distinct Signaling Pathways After Higher or Lower Doses of Radiation in Three Closely Related Human Lymphoblast Cell Lines

    International Nuclear Information System (INIS)

    Lu, T.-P.; Lai, L.-C.; Lin, B.-I.; Chen, L.-H.; Hsiao, T.-H.; Liber, Howard L.; Cook, John A.; Mitchell, James B.; Tsai, M.-H.; Chuang, Eric Y.

    2010-01-01

    Purpose: The tumor suppressor p53 plays an essential role in cellular responses to DNA damage caused by ionizing radiation; therefore, this study aims to further explore the role that p53 plays at different doses of radiation. Materials and Methods: The global cellular responses to higher-dose (10 Gy) and lower dose (iso-survival dose, i.e., the respective D0 levels) radiation were analyzed using microarrays in three human lymphoblast cell lines with different p53 status: TK6 (wild-type p53), NH32 (p53-null), and WTK1 (mutant p53). Total RNAs were extracted from cells harvested at 0, 1, 3, 6, 9, and 24 h after higher and lower dose radiation exposures. Template-based clustering, hierarchical clustering, and principle component analysis were applied to examine the transcriptional profiles. Results: Differential expression profiles between 10 Gy and iso-survival radiation in cells with different p53 status were observed. Moreover, distinct gene expression patterns were exhibited among these three cells after 10 Gy radiation treatment, but similar transcriptional responses were observed in TK6 and NH32 cells treated with iso-survival radiation. Conclusions: After 10 Gy radiation exposure, the p53 signaling pathway played an important role in TK6, whereas the NFkB signaling pathway appeared to replace the role of p53 in WTK1. In contrast, after iso-survival radiation treatment, E2F4 seemed to play a dominant role independent of p53 status. This study dissected the impacts of p53, NFkB and E2F4 in response to higher or lower doses of γ-irradiation.

  3. Signal-inducing bone cements for MRI-guided spinal cementoplasty: evaluation of contrast-agent-based polymethylmethacrylate cements

    International Nuclear Information System (INIS)

    Bail, Hermann Josef; Tsitsilonis, Serafim; Wichlas, Florian; Sattig, Christoph; Papanikolaou, Ioannis; Teichgraeber, Ulf Karl Mart

    2012-01-01

    The purpose of this work is to evaluate two signal-inducing bone cements for MRI-guided spinal cementoplasty. The bone cements were made of polymethylmethacrylate (PMMA, 5 ml monomeric, 12 g polymeric) and gadoterate meglumine as a contrast agent (CA, 0-40 μl) with either saline solution (NaCl, 2-4 ml) or hydroxyapatite bone substitute (HA, 2-4 ml). The cement's signal was assessed in an open 1-Tesla MR scanner, with T1W TSE and fast interventional T1W TSE pulse sequences, and the ideal amount of each component was determined. The compressive and bending strength for different amounts of NaCl and HA were evaluated. The cement's MRI signal depended on the concentration of CA, the amount of NaCl or HA, and the pulse sequence. The signal peaks were recorded between 1 and 10 μl CA per ml NaCl or HA, and were higher in fast T1W TSE than in T1W TSE images. The NaCl-PMMA-CA cements had a greater MRI signal intensity and compressive strength; the HA-PMMA-CA cements had a superior bending strength. Concerning the MR signal and biomechanical properties, these cements would permit MRI-guided cementoplasty. Due to its higher signal and greater compressive strength, the NaCl-PMMA-CA compound appears to be superior to the HA-PMMA-CA compound. (orig.)

  4. Is there any correlation between model-based perfusion parameters and model-free parameters of time-signal intensity curve on dynamic contrast enhanced MRI in breast cancer patients?

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Boram; Kang, Doo Kyoung; Kim, Tae Hee [Ajou University School of Medicine, Department of Radiology, Suwon, Gyeonggi-do (Korea, Republic of); Yoon, Dukyong [Ajou University School of Medicine, Department of Biomedical Informatics, Suwon (Korea, Republic of); Jung, Yong Sik; Kim, Ku Sang [Ajou University School of Medicine, Department of Surgery, Suwon (Korea, Republic of); Yim, Hyunee [Ajou University School of Medicine, Department of Pathology, Suwon (Korea, Republic of)

    2014-05-15

    To find out any correlation between dynamic contrast-enhanced (DCE) model-based parameters and model-free parameters, and evaluate correlations between perfusion parameters with histologic prognostic factors. Model-based parameters (Ktrans, Kep and Ve) of 102 invasive ductal carcinomas were obtained using DCE-MRI and post-processing software. Correlations between model-based and model-free parameters and between perfusion parameters and histologic prognostic factors were analysed. Mean Kep was significantly higher in cancers showing initial rapid enhancement (P = 0.002) and a delayed washout pattern (P = 0.001). Ve was significantly lower in cancers showing a delayed washout pattern (P = 0.015). Kep significantly correlated with time to peak enhancement (TTP) (ρ = -0.33, P < 0.001) and washout slope (ρ = 0.39, P = 0.002). Ve was significantly correlated with TTP (ρ = 0.33, P = 0.002). Mean Kep was higher in tumours with high nuclear grade (P = 0.017). Mean Ve was lower in tumours with high histologic grade (P = 0.005) and in tumours with negative oestrogen receptor status (P = 0.047). TTP was shorter in tumours with negative oestrogen receptor status (P = 0.037). We could acquire general information about the tumour vascular physiology, interstitial space volume and pathologic prognostic factors by analyzing time-signal intensity curve without a complicated acquisition process for the model-based parameters. (orig.)

  5. T2-weighted signal intensity-selected volumetry for prediction of pathological complete response after preoperative chemoradiotherapy in locally advanced rectal cancer.

    Science.gov (United States)

    Kim, Sungwon; Han, Kyunghwa; Seo, Nieun; Kim, Hye Jin; Kim, Myeong-Jin; Koom, Woong Sub; Ahn, Joong Bae; Lim, Joon Seok

    2018-06-01

    To evaluate the diagnostic value of signal intensity (SI)-selected volumetry findings in T2-weighted magnetic resonance imaging (MRI) as a potential biomarker for predicting pathological complete response (pCR) to preoperative chemoradiotherapy (CRT) in patients with rectal cancer. Forty consecutive patients with pCR after preoperative CRT were compared with 80 age- and sex-matched non-pCR patients in a case-control study. SI-selected tumor volume was measured on post-CRT T2-weighted MRI, which included voxels of the treated tumor exceeding the SI (obturator internus muscle SI + [ischiorectal fossa fat SI - obturator internus muscle SI] × 0.2). Three blinded readers independently rated five-point pCR confidence scores and compared the diagnostic outcome with SI-selected volumetry findings. The SI-selected volumetry protocol was validated in 30 additional rectal cancer patients. The area under the receiver-operating characteristic curve (AUC) of SI-selected volumetry for pCR prediction was 0.831, with an optimal cutoff value of 649.6 mm 3 (sensitivity 0.850, specificity 0.725). The AUC of the SI-selected tumor volume was significantly greater than the pooled AUC of readers (0.707, p volumetry in post-CRT T2-weighted MRI can help predict pCR after preoperative CRT in patients with rectal cancer. • Fibrosis and viable tumor MRI signal intensities (SIs) are difficult to distinguish. • T2 SI-selected volumetry yields high diagnostic performance for assessing pathological complete response. • T2 SI-selected volumetry is significantly more accurate than readers and non-SI-selected volumetry. • Post-chemoradiation therapy T2-weighted MRI SI-selected volumetry facilitates prediction of pathological complete response.

  6. Exploiting an ancient signalling machinery to enjoy a nitrogen fixing symbiosis.

    Science.gov (United States)

    Geurts, Rene; Lillo, Alessandra; Bisseling, Ton

    2012-08-01

    For almost a century now it has been speculated that a transfer of the largely legume-specific symbiosis with nitrogen fixing rhizobium would be profitable in agriculture [1,2]. Up to now such a step has not been achieved, despite intensive research in this era. Novel insights in the underlying signalling networks leading to intracellular accommodation of rhizobium as well as mycorrhizal fungi of the Glomeromycota order show extensive commonalities between both interactions. As mycorrhizae symbiosis can be established basically with most higher plant species it raises questions why is it only in a few taxonomic lineages that the underlying signalling network could be hijacked by rhizobium. Unravelling this will lead to insights that are essential to achieve an old dream. Copyright © 2012. Published by Elsevier Ltd.

  7. TLS FIELD DATA BASED INTENSITY CORRECTION FOR FOREST ENVIRONMENTS

    Directory of Open Access Journals (Sweden)

    J. Heinzel

    2016-06-01

    Full Text Available Terrestrial laser scanning (TLS is increasingly used for forestry applications. Besides the three dimensional point coordinates, the 'intensity' of the reflected signal plays an important role in forestry and vegetation studies. The benefit of the signal intensity is caused by the wavelength of the laser that is within the near infrared (NIR for most scanners. The NIR is highly indicative for various vegetation characteristics. However, the intensity as recorded by most terrestrial scanners is distorted by both external and scanner specific factors. Since details about system internal alteration of the signal are often unknown to the user, model driven approaches are impractical. On the other hand, existing data driven calibration procedures require laborious acquisition of separate reference datasets or areas of homogenous reflection characteristics from the field data. In order to fill this gap, the present study introduces an approach to correct unwanted intensity variations directly from the point cloud of the field data. The focus is on the variation over range and sensor specific distortions. Instead of an absolute calibration of the values, a relative correction within the dataset is sufficient for most forestry applications. Finally, a method similar to time series detrending is presented with the only pre-condition of a relative equal distribution of forest objects and materials over range. Our test data covers 50 terrestrial scans captured with a FARO Focus 3D S120 scanner using a laser wavelength of 905 nm. Practical tests demonstrate that our correction method removes range and scanner based alterations of the intensity.

  8. Stochastic resonance in a single-mode laser driven by frequency modulated signal and coloured noises

    Institute of Scientific and Technical Information of China (English)

    Jin Guo-Xiang; Zhang Liang-Ying; Cao Li

    2009-01-01

    By adding frequency modulated signals to the intensity equation of gain-noise model of the single-mode laser driven by two coloured noises which are correlated, this paper uses the linear approximation method to calculate the power spectrum and signal-to-noise ratio (SNR) of the laser intensity. The results show that the SNR appears typical stochastic resonance with the variation of intensity of the pump noise and quantum noise. As the amplitude of a modulated signal has effects on the SNR, it shows suppression, monotone increasing, stochastic resonance, and multiple stochastic resonance with the variation of the frequency of a carrier signal and modulated signal.

  9. Neuro-developmental outcome at 18 months in premature infants with diffuse excessive high signal intensity on MR imaging of the brain

    International Nuclear Information System (INIS)

    Hart, Anthony; Whitby, Elspeth; Paley, Martyn; Wilkinson, Stuart; Smith, Michael; Alladi, Sathya

    2011-01-01

    Diffuse excessive high signal intensity (DEHSI) may represent damage to the white matter in preterm infants, but may be best studied alongside quantitative markers. Limited published data exists on its neuro-developmental implications. The purpose of this study was to assess whether preterm children with DEHSI at term-corrected age have abnormal neuro-developmental outcome. This was a prospective observational study of 67 preterm infants with MRI of the brain around term-equivalent age, including diffusion-weighted imaging (DWI). Images were reported as being normal, overtly abnormal or to show DEHSI. A single observer placed six regions of interest in the periventricular white matter and calculated the apparent diffusion coefficients (ADC). DEHSI was defined as (1) high signal on T2-weighted images alone, (2) high signal with raised ADC values or (3) raised ADC values independent of visual appearances. The neuro-development was assessed around 18 months' corrected age using the Bayley Scales of Infant and Toddler Development (3rd Edition). Standard t tests compared outcome scores between imaging groups. No statistically significant difference in neuro-developmental outcome scores was seen between participants with normal MRI and DEHSI, regardless of which definition was used. Preterm children with DEHSI have similar neuro-developmental outcome to those with normal brain MRI, even if the definition includes objective markers alongside visual appearances. (orig.)

  10. Glacier Snowline Determination from Terrestrial Laser Scanning Intensity Data

    Directory of Open Access Journals (Sweden)

    Hannah Prantl

    2017-07-01

    Full Text Available Accurately identifying the extent of surface snow cover on glaciers is important for extrapolating end of year mass balance measurements, constraining the glacier surface radiative energy balance and evaluating model simulations of snow cover. Here, we use auxiliary information from Riegl VZ-6000 Terrestrial Laser Scanner (TLS return signals to accurately map the snow cover over a glacier throughout an ablation season. Three classification systems were compared, and we find that supervised classification based on TLS signal intensity alone is outperformed by a rule-based classification employing intensity, surface roughness and an associated optical image, which achieves classification accuracy of 68–100%. The TLS intensity signal shows no meaningful relationship with surface or bulk snow density. Finally, we have also compared our Snow Line Altitude (SLA derived from TLS with SLA derived from the model output, as well as one Landsat image. The results of the model output track the SLA from TLS well, however with a positive bias. In contrast, automatic Landsat-derived SLA slightly underestimates the SLA from TLS. To conclude, we demonstrate that the snow cover extent can be mapped successfully using TLS, although the snow mass remains elusive.

  11. Scaled signal intensity of uterine fibroids based on T2-weighted MR images: a potential objective method to determine the suitability for magnetic resonance-guided focused ultrasound surgery of uterine fibroids

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyun [CHA University, Comprehensive Gynecologic Cancer Center, CHA Bundang Medical Center, Gyunggi-do (Korea, Republic of); Yoon, Sang-Wook [CHA University, Department of Diagnostic Radiology, CHA Bundang Medical Center, Sungnam-si, Gyunggi-do (Korea, Republic of); Sokolov, Amit [InSightec Ltd., Haifa (Israel)

    2015-12-15

    Magnetic Resonance-guided Focused Ultrasound Surgery (MRgFUS) is a non-invasive method to treat uterine fibroids. To help determine the patient suitability for MRgFUS, we propose a new objective measure: the scaled signal intensity (SSI) of uterine fibroids in T2 weighted MR images (T2WI). Forty three uterine fibroids in 40 premenopausal women were included in this retrospective study. SSI of each fibroid was measured from the screening T2WI by standardizing its mean signal intensity to a 0-100 scale, using reference intensities of rectus abdominis muscle (0) and subcutaneous fat (100). Correlation between the SSI and the non-perfused volume (NPV) ratio (a measure for treatment success) was calculated. Pre-treatment SSI showed a significant inverse-correlation with post treatment NPV ratio (p < 0.05). When dichotomizing NPV ratio at 45 %, the optimal cut off value of the SSI was found to be 16.0. A fibroid with SSI value 16.0 or less can be expected to have optimal responses. The SSI of uterine fibroids in T2WI can be suggested as an objective parameter to help in patient selection for MRgFUS. (orig.)

  12. ESR signals in quartz for the studies of earth surface processes

    Science.gov (United States)

    Toyoda, S.; Shimada, A., , Dr; Takada, M.

    2017-12-01

    Various ESR (electron spin resonance) signals are observed in quartz. As they are formed by natural radiation, the signals are useful in dating of geological events, such as volcanic eruption, faulting and sedimentation. It was also found that those paramagnetic defects can be fingerprints of sediments, to be used for studies in sediment provenance. The signal of the E1' center, unpaired electron at an oxygen vacancy, was first used for such studies. A method was proposed to estimate the number of the precursors (oxygen vacancies) from the E1' center intensity. The number of oxygen vacancies in quartz was found to have positive correlation with the crystallization age. Using this feature, studies were quite successful in aeolian dust. It was shown that the sources of aeolian dust deposited in northern part of Japanese Islands were different between in MIS1 and MIS 2. In combination with crystallinity index, the contributions of the dust components from three origins were quantitatively obtained. After these, the provenance studies on river sediments have started where the impurity centers in quartz were employed, which are the Al center, the Ti centers, and the Ge centers. Sediments of Kizu River, Mie to Nara prefectures in Central Japan are most extensively studied. Firstly, it was shown that each of possible sources of granitic quartz around the reaches has respective characteristics in the number of oxygen vacancies and the signal intensities of impurity centers. Secondary, by the artificial mixing experiments, the impurity signal intensities have the values consistent with the mixing ratio of the two samples of quartz with different intensities. At river junctions, the mixing ratios were calculated from the ESR signals. At some locations, the mixing ratio values obtained from one signal were consistent with the ones from another signal while at some locations they were not. The latter inconsistent results would indicate that the river sediments are

  13. Motor unit recruitment patterns 2: the influence of myoelectric intensity and muscle fascicle strain rate.

    Science.gov (United States)

    Hodson-Tole, Emma F; Wakeling, James M

    2008-06-01

    To effectively meet the force requirements of a given movement an appropriate number and combination of motor units must be recruited between and within muscles. Orderly recruitment of motor units has been shown to occur in a wide range of skeletal muscles, however, alternative strategies do occur. Faster motor units are better suited to developing force rapidly, and produce higher mechanical power with greater efficiency at faster shortening strain rates than slower motor units. As the frequency content of the myoelectric signal is related to the fibre type of the active motor units, we hypothesised that, in addition to an association between myoelectric frequency and intensity, there would be a significant association between muscle fascicle shortening strain rate and myoelectric frequency content. Myoelectric and sonomicrometric data were collected from the three ankle extensor muscles of the rat hind limb during walking and running. Myoelectric signals were analysed using wavelet transformation and principal component analysis to give a measure of the signal frequency content. Sonomicrometric signals were analysed to give measures of muscle fascicle strain and strain rate. The relationship between myoelectric frequency and both intensity and muscle fascicle strain rate was found to change across the time course of a stride, with differences also occurring in the strength of the associations between and within muscles. In addition to the orderly recruitment of motor units, a mechanical strategy of motor unit recruitment was therefore identified. Motor unit recruitment is therefore a multifactorial phenomenon, which is more complex than typically thought.

  14. Cryogenic semiconductor high-intensity radiation monitors

    International Nuclear Information System (INIS)

    Palmieri, V.G.; Bell, W.H.; Borer, K.; Casagrande, L.; Da Via, C.; Devine, S.R.H.; Dezillie, B.; Esposito, A.; Granata, V.; Hauler, F.; Jungermann, L.; Li, Z.; Lourenco, C.; Niinikoski, T.O.; Shea, V. O'; Ruggiero, G.; Sonderegger, P.

    2003-01-01

    This paper describes a novel technique to monitor high-intensity particle beams by means of a semiconductor detector. It consists of cooling a semiconductor detector down to cryogenic temperature to suppress the thermally generated leakage current and to precisely measure the integrated ionization signal. It will be shown that such a device provides very good linearity and a dynamic range wider than is possible with existing techniques. Moreover, thanks to the Lazarus effect, extreme radiation hardness can be achieved providing in turn absolute intensity measurements against precise calibration of the device at low beam flux

  15. Effect of resistance exercise intensity on the expression of PGC-1α isoforms and the anabolic and catabolic signaling mediators, IGF-1 and myostatin, in human skeletal muscle.

    Science.gov (United States)

    Schwarz, Neil A; McKinley-Barnard, Sarah K; Spillane, Mike B; Andre, Thomas L; Gann, Joshua J; Willoughby, Darryn S

    2016-08-01

    The purpose of this study was to investigate the acute messenger (mRNA) expression of the peroxisome proliferator-activated receptor γ coactivator-1α (PGC-1α) isoforms, insulin-like growth factor-1Ea (IGF-1Ea), and myostatin in response to 2 resistance exercise intensities. In a uniform-balanced, crossover design, 10 participants performed 2 separate testing sessions involving a lower body resistance exercise component consisting of a lower intensity (50% of 1-repetition maximum; 1RM) protocol and a higher intensity (80% of 1RM) protocol of equal volumes. Muscle samples were obtained at before exercise, 45 min, 3 h, 24 h, and 48 h postexercise. Resistance exercise did not alter total PGC-1α mRNA expression; however, distinct responses of each PGC-1α isoform were observed. The response of each isoform was consistent between sessions, suggesting no effect of resistance exercise intensity on the complex transcriptional expression of the PGC-1α gene. IGF-1Ea mRNA expression significantly increased following the higher intensity session compared with pre-exercise and the lower intensity session. Myostatin mRNA expression was significantly reduced compared with pre-exercise values at all time points with no difference between exercise intensity. Further research is needed to determine the effects of the various isoforms of PGC-1α in human skeletal muscle on the translational level as well as their relation to the expression of IGF-1 and myostatin.

  16. Pump to signal noise transfer in parametric fiber amplifiers

    DEFF Research Database (Denmark)

    Lund-Hansen, Toke; Rottwitt, Karsten; Peucheret, Christophe

    2010-01-01

    Fiber optic parametric amplifiers have been suggested due to their potential low spontaneous emission. However, by nature the parametric amplifier only work in a forward pumped configuration, which result in transfer of relative intensity noise in the pump to the signal.......Fiber optic parametric amplifiers have been suggested due to their potential low spontaneous emission. However, by nature the parametric amplifier only work in a forward pumped configuration, which result in transfer of relative intensity noise in the pump to the signal....

  17. Heparanase augments insulin receptor signaling in breast carcinoma

    Science.gov (United States)

    Goldberg, Rachel; Sonnenblick, Amir; Hermano, Esther; Hamburger, Tamar; Meirovitz, Amichay; Peretz, Tamar; Elkin, Michael

    2017-01-01

    Recently, growing interest in the potential link between metabolic disorders (i.e., diabetes, obesity, metabolic syndrome) and breast cancer has mounted, including studies which indicate that diabetic/hyperinsulinemic women have a significantly higher risk of bearing breast tumors that are more aggressive and associated with higher death rates. Insulin signaling is regarded as a major contributor to this phenomenon; much less is known about the role of heparan sulfate-degrading enzyme heparanase in the link between metabolic disorders and cancer. In the present study we analyzed clinical samples of breast carcinoma derived from diabetic/non-diabetic patients, and investigated effects of heparanase on insulin signaling in breast carcinoma cell lines, as well as insulin-driven growth of breast tumor cells. We demonstrate that heparanase activity leads to enhanced insulin signaling and activation of downstream tumor-promoting pathways in breast carcinoma cells. In agreement, heparanase enhances insulin-induced proliferation of breast tumor cells in vitro. Moreover, analyzing clinical data from diabetic breast carcinoma patients, we found that concurrent presence of both diabetic state and heparanase in tumor tissue (as opposed to either condition alone) was associated with more aggressive phenotype of breast tumors in the patient cohort analyzed in our study (two-sided Fisher's exact test; p=0.04). Our findings highlight the emerging role of heparanase in powering effect of hyperinsulinemic state on breast tumorigenesis and imply that heparanase targeting, which is now under intensive development/clinical testing, could be particularly efficient in a growing fraction of breast carcinoma patients suffering from metabolic disorders. PMID:28038446

  18. Scaling of Optogenetically Evoked Signaling in a Higher-Order Corticocortical Pathway in the Anesthetized Mouse

    Directory of Open Access Journals (Sweden)

    Xiaojian Li

    2018-05-01

    Full Text Available Quantitative analysis of corticocortical signaling is needed to understand and model information processing in cerebral networks. However, higher-order pathways, hodologically remote from sensory input, are not amenable to spatiotemporally precise activation by sensory stimuli. Here, we combined parametric channelrhodopsin-2 (ChR2 photostimulation with multi-unit electrophysiology to study corticocortical driving in a parietofrontal pathway from retrosplenial cortex (RSC to posterior secondary motor cortex (M2 in mice in vivo. Ketamine anesthesia was used both to eliminate complex activity associated with the awake state and to enable stable recordings of responses over a wide range of stimulus parameters. Photostimulation of ChR2-expressing neurons in RSC, the upstream area, produced local activity that decayed quickly. This activity in turn drove downstream activity in M2 that arrived rapidly (5–10 ms latencies, and scaled in amplitude across a wide range of stimulus parameters as an approximately constant fraction (~0.1 of the upstream activity. A model-based analysis could explain the corticocortically driven activity with exponentially decaying kernels (~20 ms time constant and small delay. Reverse (antidromic driving was similarly robust. The results show that corticocortical signaling in this pathway drives downstream activity rapidly and scalably, in a mostly linear manner. These properties, identified in anesthetized mice and represented in a simple model, suggest a robust basis for supporting complex non-linear dynamic activity in corticocortical circuits in the awake state.

  19. Scaling of Optogenetically Evoked Signaling in a Higher-Order Corticocortical Pathway in the Anesthetized Mouse.

    Science.gov (United States)

    Li, Xiaojian; Yamawaki, Naoki; Barrett, John M; Körding, Konrad P; Shepherd, Gordon M G

    2018-01-01

    Quantitative analysis of corticocortical signaling is needed to understand and model information processing in cerebral networks. However, higher-order pathways, hodologically remote from sensory input, are not amenable to spatiotemporally precise activation by sensory stimuli. Here, we combined parametric channelrhodopsin-2 (ChR2) photostimulation with multi-unit electrophysiology to study corticocortical driving in a parietofrontal pathway from retrosplenial cortex (RSC) to posterior secondary motor cortex (M2) in mice in vivo . Ketamine anesthesia was used both to eliminate complex activity associated with the awake state and to enable stable recordings of responses over a wide range of stimulus parameters. Photostimulation of ChR2-expressing neurons in RSC, the upstream area, produced local activity that decayed quickly. This activity in turn drove downstream activity in M2 that arrived rapidly (5-10 ms latencies), and scaled in amplitude across a wide range of stimulus parameters as an approximately constant fraction (~0.1) of the upstream activity. A model-based analysis could explain the corticocortically driven activity with exponentially decaying kernels (~20 ms time constant) and small delay. Reverse (antidromic) driving was similarly robust. The results show that corticocortical signaling in this pathway drives downstream activity rapidly and scalably, in a mostly linear manner. These properties, identified in anesthetized mice and represented in a simple model, suggest a robust basis for supporting complex non-linear dynamic activity in corticocortical circuits in the awake state.

  20. Hyper-Ramsey spectroscopy with probe-laser-intensity fluctuations

    Science.gov (United States)

    Beloy, K.

    2018-03-01

    We examine the influence of probe-laser-intensity fluctuations on hyper-Ramsey spectroscopy. We assume, as is appropriate for relevant cases of interest, that the probe-laser intensity I determines both the Rabi frequency (∝√{I } ) and the frequency shift to the atomic transition (∝I ) during probe-laser interactions with the atom. The spectroscopic signal depends on these two quantities that covary with fluctuations in the probe-laser intensity. Introducing a simple model for the fluctuations, we find that the signature robustness of the hyper-Ramsey method can be compromised. Taking the Yb+ electric octupole clock transition as an example, we quantify the clock error under different levels of probe-laser-intensity fluctuations.

  1. G-stack modulated probe intensities on expression arrays - sequence corrections and signal calibration

    Directory of Open Access Journals (Sweden)

    Fasold Mario

    2010-04-01

    Full Text Available Abstract Background The brightness of the probe spots on expression microarrays intends to measure the abundance of specific mRNA targets. Probes with runs of at least three guanines (G in their sequence show abnormal high intensities which reflect rather probe effects than target concentrations. This G-bias requires correction prior to downstream expression analysis. Results Longer runs of three or more consecutive G along the probe sequence and in particular triple degenerated G at its solution end ((GGG1-effect are associated with exceptionally large probe intensities on GeneChip expression arrays. This intensity bias is related to non-specific hybridization and affects both perfect match and mismatch probes. The (GGG1-effect tends to increase gradually for microarrays of later GeneChip generations. It was found for DNA/RNA as well as for DNA/DNA probe/target-hybridization chemistries. Amplification of sample RNA using T7-primers is associated with strong positive amplitudes of the G-bias whereas alternative amplification protocols using random primers give rise to much smaller and partly even negative amplitudes. We applied positional dependent sensitivity models to analyze the specifics of probe intensities in the context of all possible short sequence motifs of one to four adjacent nucleotides along the 25meric probe sequence. Most of the longer motifs are adequately described using a nearest-neighbor (NN model. In contrast, runs of degenerated guanines require explicit consideration of next nearest neighbors (GGG terms. Preprocessing methods such as vsn, RMA, dChip, MAS5 and gcRMA only insufficiently remove the G-bias from data. Conclusions Positional and motif dependent sensitivity models accounts for sequence effects of oligonucleotide probe intensities. We propose a positional dependent NN+GGG hybrid model to correct the intensity bias associated with probes containing poly-G motifs. It is implemented as a single-chip based calibration

  2. The cellular response to vascular endothelial growth factors requires co-ordinated signal transduction, trafficking and proteolysis.

    Science.gov (United States)

    Smith, Gina A; Fearnley, Gareth W; Tomlinson, Darren C; Harrison, Michael A; Ponnambalam, Sreenivasan

    2015-08-18

    VEGFs (vascular endothelial growth factors) are a family of conserved disulfide-linked soluble secretory glycoproteins found in higher eukaryotes. VEGFs mediate a wide range of responses in different tissues including metabolic homoeostasis, cell proliferation, migration and tubulogenesis. Such responses are initiated by VEGF binding to soluble and membrane-bound VEGFRs (VEGF receptor tyrosine kinases) and co-receptors. VEGF and receptor splice isoform diversity further enhances complexity of membrane protein assembly and function in signal transduction pathways that control multiple cellular responses. Different signal transduction pathways are simultaneously activated by VEGFR-VEGF complexes with membrane trafficking along the endosome-lysosome network further modulating signal output from multiple enzymatic events associated with such pathways. Balancing VEGFR-VEGF signal transduction with trafficking and proteolysis is essential in controlling the intensity and duration of different intracellular signalling events. Dysfunction in VEGF-regulated signal transduction is important in chronic disease states including cancer, atherosclerosis and blindness. This family of growth factors and receptors is an important model system for understanding human disease pathology and developing new therapeutics for treating such ailments. © 2015 Authors.

  3. A study on magnetic relaxation times of various organs and body fluids using superconducting magnetic resonance imaging system part I: measurement of relative signal intensity and T2 relaxation time in various portions of brain and cerebrospinal fluid

    International Nuclear Information System (INIS)

    Chang, Kee Hyun; Lee, Ghi Jai; Han, Moon Hee; Kim, Jae Ho; Han, Man Chang; Kim, Chu Wan

    1988-01-01

    This study was undertake to determine if routine clinical magnetic resonance imaging sequences using only two different repetition times (TRs) and with only two sequential echo times (TEs) can be used to measure reproducible relative signal intensity and T2 relaxation time for normal brain tissues and cerebrospinal fluid using a 2.0T superconducting system. In 47 patients 6 different anatomic sites were measured. For each anatomic location, the mean and standard deviation of these values were determined. On T1-weighted (SE 500msec/30msec) images, in globus pallidus and thalamus, of the CSF, cortical gray matter and retrobulbar fat tissue varied more, with a standard deviation of 11-14% on T1-weighted images. On T2-weighted (SE 3000msec/30msec and 3000msec/80msec) images, the relative signal intensity of all anatomic regions varied more than on T1-weighted images. The standard deviation of T2 relaxation times also varied from 10% (fat tissue) to 18% (CSF). These variations might be due to partial volume averaging, signal alteration of CSF secondary to CSF pulsatile motion, etc. Knowing that relative signal intensity and T2 relaxation times calculated from routine imaging sequences are reproducible in only limited area, these normal ranges can be used to investigate changes occurring in disease states of the limited regions.

  4. Experimental assessment of fluorescence microscopy signal enhancement by stimulated emission

    Science.gov (United States)

    Dake, Fumihiro; Yazawa, Hiroki

    2017-10-01

    The quantity of photons generated during fluorescence microscopy is principally determined by the quantum yield of the fluorescence dyes and the optical power of the excitation beam. However, even though low quantum yields can produce poor images, it is challenging to tune this parameter, while increasing the power of the excitation beam often results in photodamage. Here, we propose the use of stimulated emission (SE) as a means of enhancing both the signal intensity and signal-to-noise ratio during confocal fluorescence microscopy. This work experimentally confirmed that both these factors can be enhanced by SE radiation, through generating a greater number of photons than are associated with the standard fluorescence signal. We also propose the concept of stimulated emission enhancing fluorescence (SEEF) microscopy, which employs both the SE and fluorescence signals, and demonstrate that the intensity of an SEEF signal is greater than those of the individual SE and fluorescence signals.

  5. Short term ionizing radiation impact on charge-coupled devices in radiation environment of high-intensity heavy ion accelerators

    International Nuclear Information System (INIS)

    Belousov, A.; Mustafin, E.; Ensinger, W.

    2012-01-01

    This paper presents a first approach on studies of the results of short term ionizing radiation impact on charge-coupled device (CCD) chips in conditions typical for high-intensity ion accelerator areas. Radiation effects on semiconductor devices are a topical issue for high-intensity accelerator projects. In particular it concerns CCD cameras that are widely used for beam profile monitoring and surveillance in high radiation environment. 65 CCD cameras are going to be installed in the FAIR machines. It is necessary to have good understanding of radiation effects and their contribution to measured signal in CCD chips. A phenomenon of single event upset (SEU) in CCD chips is studied in the following experiment. By SEU in CCD chip we mean an event when an ionizing particle hits the CCD matrix cell and produces electron-hole pairs that are then collected and converted to a signal that is higher than certain level defined by author. Practically, it means that a certain cell will appear as a bright pixel on the resulting image from a chip. (authors)

  6. High-intensity high-volume swimming induces more robust signaling through PGC-1α and AMPK activation than sprint interval swimming in m. triceps brachii

    DEFF Research Database (Denmark)

    Casuso, Rafael A; Plaza-Díaz, Julio; Ruiz-Ojeda, Francisco J

    2017-01-01

    We aimed to test whether high-intensity high-volume training (HIHVT) swimming would induce more robust signaling than sprint interval training (SIT) swimming within the m. triceps brachii due to lower metabolic and oxidation. Nine well-trained swimmers performed the two training procedures...... on separate randomized days. Muscle biopsies from m. triceps brachii and blood samples were collected at three different time points: a) before the intervention (pre), b) immediately after the swimming procedures (post) and c) after 3 h of rest (3 h). Hydroperoxides, creatine kinase (CK), and lactate...

  7. Aberrant Wnt Signaling in Leukemia

    Directory of Open Access Journals (Sweden)

    Frank J. T. Staal

    2016-08-01

    Full Text Available The Wnt signaling pathway is essential in the development and homeostasis of blood and immune cells, but its exact role is still controversial and is the subject of intense research. The malignant counterpart of normal hematopoietic cells, leukemic (stem cells, have hijacked the Wnt pathway for their self-renewal and proliferation. Here we review the multiple ways dysregulated Wnt signaling can contribute to leukemogenesis, both cell autonomously as well as by changes in the microenvironment.

  8. Neural Correlates of Success and Failure Signals During Neurofeedback Learning.

    Science.gov (United States)

    Radua, Joaquim; Stoica, Teodora; Scheinost, Dustin; Pittenger, Christopher; Hampson, Michelle

    2018-05-15

    Feedback-driven learning, observed across phylogeny and of clear adaptive value, is frequently operationalized in simple operant conditioning paradigms, but it can be much more complex, driven by abstract representations of success and failure. This study investigates the neural processes involved in processing success and failure during feedback learning, which are not well understood. Data analyzed were acquired during a multisession neurofeedback experiment in which ten participants were presented with, and instructed to modulate, the activity of their orbitofrontal cortex with the aim of decreasing their anxiety. We assessed the regional blood-oxygenation-level-dependent response to the individualized neurofeedback signals of success and failure across twelve functional runs acquired in two different magnetic resonance sessions in each of ten individuals. Neurofeedback signals of failure correlated early during learning with deactivation in the precuneus/posterior cingulate and neurofeedback signals of success correlated later during learning with deactivation in the medial prefrontal/anterior cingulate cortex. The intensity of the latter deactivations predicted the efficacy of the neurofeedback intervention in the reduction of anxiety. These findings indicate a role for regulation of the default mode network during feedback learning, and suggest a higher sensitivity to signals of failure during the early feedback learning and to signals of success subsequently. Copyright © 2016 IBRO. Published by Elsevier Ltd. All rights reserved.

  9. Appearances of diffuse excessive high signal intensity (DEHSI) on MR imaging following preterm birth

    International Nuclear Information System (INIS)

    Hart, Anthony R.; Smith, Michael F.; Rigby, Alan S.; Wallis, Lauren I.; Whitby, Elspeth H.

    2010-01-01

    Diffuse damage to the periventricular white matter has recently been suggested to be a cause of the cognitive deficits seen following preterm birth. It is unclear whether this form of injury can be visualised on MR imaging, but one group has described diffuse excessive high signal intensity (DEHSI) as a possible form of diffuse white matter injury. This finding is dependant on window imaging and the subjective assessment of the reviewer, but little data have been published on the degree of subjectivity on its appearance among raters. To assess the subjectivity of DEHSI on conventional and ultrafast T2-weighted MR imaging following preterm birth. An observational study of 40 preterm infants who had MR imaging of the brain around term-equivalent age, including conventional fast spin-echo (FSE) and ultrafast single-shot fast spin-echo (SSFSE) T2-weighted sequences in the axial plane. Images were anonymised and scored twice by four observers for the presence of DEHSI. Inter- and intra-observer agreement were calculated. Sixty-five percent of conventional and 100% of the ultrafast images were of diagnostic quality. DEHSI was noted in between 0% and 69.2% of conventional images and 27.5-90% of the ultrafast images. Inter- and intra-observer agreement ranged from none to moderate. The visual appearances of DEHSI on conventional FSE and ultrafast SSFSE T2-W images are highly subjective, limiting its clinical application. (orig.)

  10. Appearances of diffuse excessive high signal intensity (DEHSI) on MR imaging following preterm birth

    Energy Technology Data Exchange (ETDEWEB)

    Hart, Anthony R. [Sheffield Teaching Hospital NHS Foundation Trust, Department of Neonatology, Jessop Wing, Sheffield (United Kingdom); University of Sheffield, Academic Unit of Radiology, Royal Hallamshire Hospital, Sheffield (United Kingdom); University of Sheffield, Department of Academic Radiology, Royal Hallamshire Hospital, Sheffield (United Kingdom); Smith, Michael F. [Sheffield Teaching Hospital NHS Foundation Trust, Department of Neonatology, Jessop Wing, Sheffield (United Kingdom); Rigby, Alan S. [University of Hull, Postgraduate Medical Centre, Castle Hill Hospital, East Yorkshire (United Kingdom); Wallis, Lauren I.; Whitby, Elspeth H. [University of Sheffield, Academic Unit of Radiology, Royal Hallamshire Hospital, Sheffield (United Kingdom)

    2010-08-15

    Diffuse damage to the periventricular white matter has recently been suggested to be a cause of the cognitive deficits seen following preterm birth. It is unclear whether this form of injury can be visualised on MR imaging, but one group has described diffuse excessive high signal intensity (DEHSI) as a possible form of diffuse white matter injury. This finding is dependant on window imaging and the subjective assessment of the reviewer, but little data have been published on the degree of subjectivity on its appearance among raters. To assess the subjectivity of DEHSI on conventional and ultrafast T2-weighted MR imaging following preterm birth. An observational study of 40 preterm infants who had MR imaging of the brain around term-equivalent age, including conventional fast spin-echo (FSE) and ultrafast single-shot fast spin-echo (SSFSE) T2-weighted sequences in the axial plane. Images were anonymised and scored twice by four observers for the presence of DEHSI. Inter- and intra-observer agreement were calculated. Sixty-five percent of conventional and 100% of the ultrafast images were of diagnostic quality. DEHSI was noted in between 0% and 69.2% of conventional images and 27.5-90% of the ultrafast images. Inter- and intra-observer agreement ranged from none to moderate. The visual appearances of DEHSI on conventional FSE and ultrafast SSFSE T2-W images are highly subjective, limiting its clinical application. (orig.)

  11. Signal processing for radiation detectors

    CERN Document Server

    Nakhostin, Mohammad

    2018-01-01

    This book provides a clear understanding of the principles of signal processing of radiation detectors. It puts great emphasis on the characteristics of pulses from various types of detectors and offers a full overview on the basic concepts required to understand detector signal processing systems and pulse processing techniques. Signal Processing for Radiation Detectors covers all of the important aspects of signal processing, including energy spectroscopy, timing measurements, position-sensing, pulse-shape discrimination, and radiation intensity measurement. The book encompasses a wide range of applications so that readers from different disciplines can benefit from all of the information. In addition, this resource: * Describes both analog and digital techniques of signal processing * Presents a complete compilation of digital pulse processing algorithms * Extrapolates content from more than 700 references covering classic papers as well as those of today * Demonstrates concepts with more than 340 origin...

  12. Olfactory signaling of aggressive intent in male-male contests of cave crickets (Troglophilus neglectus; Orthoptera: Rhaphidophoridae.

    Directory of Open Access Journals (Sweden)

    Nataša Stritih

    Full Text Available In animal contests, communicating aggressive motivation is most often mediated by visual or acoustic signals, while chemical signals are not expected to serve such a function since they are less able to be modulated by the sender during the changing behavioral context. We describe a rare example of ephemeral olfactory signals in terrestrial animals, signals that are emitted via protrusive scent glands in male cave crickets Troglophilus neglectus (Orthoptera, Rhaphidophoridae to reflect the state of the signaler's aggression. We correlate the intensity of behaviorally expressed aggression of the individuals in dyadic contests with the frequency and extent of their gland tissue protrusion, the latter serving as an indication of the amount of released odor. We detected large amounts of odor release during brief gland protrusions, and the absence of its release during gland retraction. Males protruded the glands during and after encountering a rival, with the degree of protrusion increasing with the intensity of the signalers' aggression. During the encounters, the degree of gland protrusion increased most strongly with the occurrence of the elevated body posture, directly preceding the attack. This degree was significantly higher in encounter winners than in losers displaying such posture, suggesting the highly important role of the released odor for contest resolution. After the encounters, glands were protruded almost exclusively by winners, apparently announcing victory. We tested for the function of the olfactory signals also directly, by preventing gland tissue protrusion in symmetric and asymmetric treatments of the contestants. Treating only the dominant individuals decreased the percentage of encounters they won by over 60%, while treating both contestants elicited a significant increase in the frequency and duration of fights. During contests, the olfactory signals of T. neglectus apparently function as a highly effective threat, which

  13. Effects of surface irregularities on intensity data from laser scanning: an experimental approach.

    Directory of Open Access Journals (Sweden)

    G. Teza

    2008-06-01

    Full Text Available The results of an experiment carried out with the aim to investigate the role of surface irregularities on the intensity data provided by a terrestrial laser scanner (TLS survey are reported here. Depending on surface roughness, the interaction between an electromagnetic wave and microscopic irregularities leads to a Lambertian-like diffusive light reflection, allowing the TLS to receive the backscattered component of the signal. The described experiment consists in a series of TLS-based acquisitions of a rotating artificial target specifically conceived in order to highlight the effects on the intensity data due to surface irregularity. This target is articulated in a flat plate and in an irregular surface, whose macro-roughness has a characteristic length with the same order of the spot size. Results point out the different behavior of the plates. The intensity of the signal backscattered by the planar element decreases if the incidence angle increases, whereas the intensity of the signal backscattered by the irregular surface is almost constant if the incidence angle varies. Since the typical surfaces acquired in a geological/geophysical survey are generally irregular, these results imply that the intensity data can be easily used in order to evaluate the reflectance of the material at the considered wavelength, e.g. for pattern recognition purposes.

  14. Application of Higher-Order Cumulant in Fault Diagnosis of Rolling Bearing

    International Nuclear Information System (INIS)

    Shen, Yongjun; Yang, Shaopu; Wang, Junfeng

    2013-01-01

    In this paper a new method of pattern recognition based on higher-order cumulant and envelope analysis is presented. The core of this new method is to construct analytical signals from the given signals and obtain the envelope signals firstly, then compute and compare the higher-order cumulants of the envelope signals. The higher-order cumulants could be used as a characteristic quantity to distinguish these given signals. As an example, this method is applied in fault diagnosis for 197726 rolling bearing of freight locomotive. The comparisons of the second-order, third-order and fourth-order cumulants of the envelope signals from different vibration signals of rolling bearing show this new method could discriminate the normal and two fault signals distinctly

  15. Vacuum ultraviolet Ar2*laser pumped by a high-intensity laser

    International Nuclear Information System (INIS)

    Kubodera, Shoichi; Kaku, Masanori; Higashiguchi, Takeshi

    2004-01-01

    We observed a small-signal gain of Ar 2 * emission at 126 nm by use of an Ar-filled hollow fiber to guide the ultrashort-pulse high-intensity laser propagation. The small signal gain coefficient was measured to be 0.05 cm -1 at 126 nm. Kinetic analysis revealed that the electrons produced by the high-intensity laser through an optical-field ionization process initiated the Ar 2 * production process. This laser scheme could be combined with high harmonic radiation of the pump laser in the vacuum ultraviolet (VUV), leading to the production of amplified ultrashort VUV pulses. (author)

  16. Quantization analysis of speckle intensity measurements for phase retrieval

    DEFF Research Database (Denmark)

    Maallo, Anne Margarette S.; Almoro, Percival F.; Hanson, Steen Grüner

    2010-01-01

    Speckle intensity measurements utilized for phase retrieval (PR) are sequentially taken with a digital camera, which introduces quantization error that diminishes the signal quality. Influences of quantization on the speckle intensity distribution and PR are investigated numerically...... and experimentally in the static wavefront sensing setup. Resultsshowthat 3 to 4 bits are adequate to represent the speckle intensities and yield acceptable reconstructions at relatively fast convergence rates. Computer memory requirements may be eased down by 2.4 times if a 4 bit instead of an 8 bit camera is used...

  17. High-intensity interval running is perceived to be more enjoyable than moderate-intensity continuous exercise: implications for exercise adherence.

    Science.gov (United States)

    Bartlett, Jonathan D; Close, Graeme L; MacLaren, Don P M; Gregson, Warren; Drust, Barry; Morton, James P

    2011-03-01

    The aim of this study was to objectively quantify ratings of perceived enjoyment using the Physical Activity Enjoyment Scale following high-intensity interval running versus moderate-intensity continuous running. Eight recreationally active men performed two running protocols consisting of high-intensity interval running (6 × 3 min at 90% VO(2max) interspersed with 6 × 3 min active recovery at 50% VO(2max) with a 7-min warm-up and cool down at 70% VO(2max)) or 50 min moderate-intensity continuous running at 70% VO(2max). Ratings of perceived enjoyment after exercise were higher (P running compared with continuous running (88 ± 6 vs. 61 ± 12) despite higher (P running may be relevant for improving exercise adherence, since running is a low-cost exercise intervention requiring no exercise equipment and similar relative exercise intensities have previously induced health benefits in patient populations.

  18. Regulation of mesenchymal stromal cells through fine tuning of canonical Wnt signaling

    Directory of Open Access Journals (Sweden)

    Jin-A Kim

    2015-05-01

    Full Text Available Mesenchymal stromal cells (MSCs have been extensively utilized for various cell therapeutic trials, but the signals regulating their stromal function remain largely unclear. Here, we show that canonical Wnt signals distinctively regulate MSCs in a biphasic manner depending on signal intensity, i.e., MSCs exhibit proliferation and progenitor self-renewal under low Wnt/β-catenin signaling, whereas they exhibit enhanced osteogenic differentiation with priming to osteoblast-like lineages under high Wnt/β-catenin signaling. Moreover, low or high levels of β-catenin in MSCs distinctly regulated the hematopoietic support of MSCs to promote proliferation or the undifferentiated state of hematopoietic progenitors, respectively. A gene expression study demonstrated that different intracellular levels of β-catenin in MSCs induce distinct transcriptomic changes in subsets of genes belonging to different gene function categories. Different β-catenin levels also induced differences in intracellular levels of the β-catenin co-factors, Tcf-1 and Lef-1. Moreover, nano-scale mass spectrometry of proteins that co-precipitated with β-catenin revealed distinctive spectra of proteins selectively interacting with β-catenin at specific expression levels. Together, these results show that Wnt/β-catenin signals can coax distinct transcription milieu to induce different transcription profiles in MSCs depending on the signal intensity and that fine-tuning of the canonical Wnt signaling intensity can regulate the phase-specific functionality of MSCs.

  19. Comparison of respiratory-induced variations in photoplethysmographic signals

    International Nuclear Information System (INIS)

    Li, Jin; Jin, Jie; Chen, Xiang; Sun, Weixin; Guo, Ping

    2010-01-01

    Photoplethysmography (PPG) is an optical method for detecting blood volume changes in tissue. Respiratory-induced intensity, frequency and amplitude variations are contained in the PPG signal; thus, an understanding of the relationships between all of these variations and respiration is essential to advancing respiration monitoring based on PPG. This study investigated correlations between respiratory-induced variations extracted from PPG and simultaneous respiratory signals. PPG signals were recorded from 28 healthy subjects under eight different conditions. Six respiratory-induced variations, i.e. the period of the systole, diastole and pulse, the amplitude of the systole and diastole, and the intensity variation, were determined from the PPG signal. The results indicate that, compared with the period of the pulse, the period of the systole and diastole correlates weakly with respiration; the amplitude of the diastole has a stronger correlation with respiration than the amplitude of the systole. For men, when the respiratory rate is less than 10 breaths min −1 , the period of the pulse has the strongest correlation with respiration, whereas up to or above 15 breaths min −1 , the intensity variation becomes strongest in the sitting posture, while the amplitude of the diastole is strongest in the supine posture. For women, compared with the other variations, the period of the pulse has nearly the strongest correlation with respiration, independent of respiratory rate or posture

  20. Prescription-event monitoring: developments in signal detection.

    Science.gov (United States)

    Ferreira, Germano

    2007-01-01

    Prescription-event monitoring (PEM) is a non-interventional intensive method for post-marketing drug safety monitoring of newly licensed medicines. PEM studies are cohort studies where exposure is obtained from a centralised service and outcomes from simple questionnaires completed by general practitioners. Follow-up forms are sent for selected events. Because PEM captures all events and not only the suspected adverse drug reactions, PEM cohorts potentially differ in respect to the distribution of number of events per person depending on the nature of the drug under study. This variance can be related either with the condition for which the drug is prescribed (e.g. a condition causing high morbidity will have, in average, a higher number of events per person compared with a condition with lower morbidity) or with the drug effect itself. This paper describes an exploratory investigation of the distortion caused by product-related variations of the number of events to the interpretation of the proportional reporting ratio (PRR) values ("the higher the PRR, the greater the strength of the signal") computed using drug-cohort data. We studied this effect by assessing the agreement between the PRR based on events (event of interest vs all other events) and PRR based on cases (cases with the event of interest vs cases with any other events). PRR were calculated for all combinations reported to ten selected drugs against a comparator of 81 other drugs. Three of the ten drugs had a cohort with an apparent higher proportion of patients with lower number of events. The PRRs based on events were systematically higher than the PRR based on cases for the combinations reported to these three drugs. Additionally, when applying the threshold criteria for signal screening (n > or =3, PRR > or =1.5 and Chi-squared > or =4), the binary agreement was generally high but apparently lower for these three drugs. In conclusion, the distribution of events per patient in drug cohorts shall be

  1. Low-Intensity Extracorporeal Shock Wave Therapy Enhances Brain-Derived Neurotrophic Factor Expression through PERK/ATF4 Signaling Pathway

    Directory of Open Access Journals (Sweden)

    Bohan Wang

    2017-02-01

    Full Text Available Low-intensity extracorporeal shock wave therapy (Li-ESWT is used in the treatment of erectile dysfunction, but its mechanisms are not well understood. Previously, we found that Li-ESWT increased the expression of brain-derived neurotrophic factor (BDNF. Here we assessed the underlying signaling pathways in Schwann cells in vitro and in penis tissue in vivo after nerve injury. The result indicated that BDNF were significantly increased by the Li-ESWT after nerve injury, as well as the expression of BDNF in Schwann cells (SCs, RT4-D6P2T in vitro. Li-ESWT activated the protein kinase RNA-like endoplasmic reticulum (ER kinase (PERK pathway by increasing the phosphorylation levels of PERK and eukaryotic initiation factor 2a (eIF2α, and enhanced activating transcription factor 4 (ATF4 in an energy-dependent manner. In addition, GSK2656157—an inhibitor of PERK—effectively inhibited the effect of Li-ESWT on the phosphorylation of PERK, eIF2α, and the expression of ATF4. Furthermore, silencing ATF4 dramatically attenuated the effect of Li-ESWT on the expression of BDNF, but had no effect on hypoxia-inducible factor (HIF1α or glial cell-derived neurotrophic factor (GDNF in Schwann cells. In conclusion, our findings shed new light on the underlying mechanisms by which Li-ESWT may stimulate the expression of BDNF through activation of PERK/ATF4 signaling pathway. This information may help to refine the use of Li-ESWT to further improve its clinical efficacy.

  2. Reconfiguring the Higher Education Value Chain

    Science.gov (United States)

    Pathak, Virendra; Pathak, Kavita

    2010-01-01

    Forces of demand and supply are changing the dynamics of the higher education market. Transformation of institutions of higher learning into competitive enterprise is underway. Higher education institutions are seemingly under intense pressure to create value and focus their efforts and scarce funds on activities that drive up value for their…

  3. Usefulness of perfusion weighted magnetic resonance imaging with signal-intensity curves analysis in the differential diagnosis of sellar and parasellar tumors: Preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Bladowska, Joanna, E-mail: asia.bladowska@gmail.com [Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw Medical University, Borowska 213, 50-556 Wroclaw (Poland); Zimny, Anna, E-mail: abernac@wp.pl [Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw Medical University, Borowska 213, 50-556 Wroclaw (Poland); Guziński, Maciej, E-mail: guziol@wp.pl [Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw Medical University, Borowska 213, 50-556 Wroclaw (Poland); Hałoń, Agnieszka, E-mail: ahalon2@gmail.com [Department of Pathomorphology and Oncological Cytology, Wroclaw Medical University, Borowska 213, 50-556 Wroclaw (Poland); Tabakow, Paweł, E-mail: p.tabakov@wp.pl [Department of Neurosurgery, Wroclaw Medical University, Borowska 213, 50-556 Wroclaw (Poland); Czyż, Marcin, E-mail: mt.czyz@gmail.com [Department of Neurosurgery, Wroclaw Medical University, Borowska 213, 50-556 Wroclaw (Poland); Czapiga, Bogdan, E-mail: bogdanczapiga@op.pl [Department of Neurosurgery, Wroclaw Medical University, Borowska 213, 50-556 Wroclaw (Poland); Jarmundowicz, Włodzimierz, E-mail: jarmund@wp.pl [Department of Neurosurgery, Wroclaw Medical University, Borowska 213, 50-556 Wroclaw (Poland); Sąsiadek, Marek J., E-mail: marek.sasiadek@am.wroc.pl [Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw Medical University, Borowska 213, 50-556 Wroclaw (Poland)

    2013-08-15

    Purpose: The most common pituitary tumors are adenomas, which however may be mimicked by other tumors that can show a very similar appearance in plain MRI. The aim of our study was to evaluate the usefulness of perfusion weighted MR imaging (PWI), including signal-intensity curves analysis in the differential diagnosis of sellar/parasellar tumors. Methods: Forty-one patients with sellar/parasellar tumors (23 macroadenomas, 10 meningiomas, 5 craniopharyngiomas, 1 intrasellar hemangioblastoma, 1 intrasellar prostate cancer metastasis, 1 suprasellar glioma), underwent plain MRI followed by PWI using a 1.5T unit. In each tumor, the mean and maximum values of relative cerebral blood volume (rCBV), as well as the relative peak height (rPH) and the relative percentage of signal intensity recovery (rPSR) were calculated. Results: The high perfusion tumors were: macroadenomas, meningiomas, squamous-papillary type of craniopharyngiomas, hemangioblastoma, glioma and metastasis. The low perfusion neoplasms included adamantinomatous type of craniopharyngiomas. By comparing adenomas and meningiomas, we found statistically significant differences in the mean and maximum rCBV values (p = 0.026 and p = 0.019, respectively), but not in rPH and rPSR. The maximum rCBV values >7.14 and the mean rCBV values >5.74 with the typical perfusion curve were very suggestive of the diagnosis of meningioma. There were differences between adenomas and other high perfusion tumors in rPH and rPSR values. Conclusions: PWI can provide additional information helpful in differential diagnosis of sellar/parasellar tumors. In our opinion PWI, as an easy to perform and fast technique should be incorporated into the MR protocol of all intracranial neoplasms including sellar/parasellar tumors.

  4. Usefulness of perfusion weighted magnetic resonance imaging with signal-intensity curves analysis in the differential diagnosis of sellar and parasellar tumors: Preliminary report

    International Nuclear Information System (INIS)

    Bladowska, Joanna; Zimny, Anna; Guziński, Maciej; Hałoń, Agnieszka; Tabakow, Paweł; Czyż, Marcin; Czapiga, Bogdan; Jarmundowicz, Włodzimierz; Sąsiadek, Marek J.

    2013-01-01

    Purpose: The most common pituitary tumors are adenomas, which however may be mimicked by other tumors that can show a very similar appearance in plain MRI. The aim of our study was to evaluate the usefulness of perfusion weighted MR imaging (PWI), including signal-intensity curves analysis in the differential diagnosis of sellar/parasellar tumors. Methods: Forty-one patients with sellar/parasellar tumors (23 macroadenomas, 10 meningiomas, 5 craniopharyngiomas, 1 intrasellar hemangioblastoma, 1 intrasellar prostate cancer metastasis, 1 suprasellar glioma), underwent plain MRI followed by PWI using a 1.5T unit. In each tumor, the mean and maximum values of relative cerebral blood volume (rCBV), as well as the relative peak height (rPH) and the relative percentage of signal intensity recovery (rPSR) were calculated. Results: The high perfusion tumors were: macroadenomas, meningiomas, squamous-papillary type of craniopharyngiomas, hemangioblastoma, glioma and metastasis. The low perfusion neoplasms included adamantinomatous type of craniopharyngiomas. By comparing adenomas and meningiomas, we found statistically significant differences in the mean and maximum rCBV values (p = 0.026 and p = 0.019, respectively), but not in rPH and rPSR. The maximum rCBV values >7.14 and the mean rCBV values >5.74 with the typical perfusion curve were very suggestive of the diagnosis of meningioma. There were differences between adenomas and other high perfusion tumors in rPH and rPSR values. Conclusions: PWI can provide additional information helpful in differential diagnosis of sellar/parasellar tumors. In our opinion PWI, as an easy to perform and fast technique should be incorporated into the MR protocol of all intracranial neoplasms including sellar/parasellar tumors

  5. Intensity inhomogeneity correction for magnetic resonance imaging of human brain at 7T

    International Nuclear Information System (INIS)

    Uwano, Ikuko; Yamashita, Fumio; Higuchi, Satomi; Ito, Kenji; Sasaki, Makoto; Kudo, Kohsuke; Goodwin, Jonathan; Harada, Taisuke; Ogawa, Akira

    2014-01-01

    Purpose: To evaluate the performance and efficacy for intensity inhomogeneity correction of various sequences of the human brain in 7T MRI using the extended version of the unified segmentation algorithm. Materials: Ten healthy volunteers were scanned with four different sequences (2D spin echo [SE], 3D fast SE, 2D fast spoiled gradient echo, and 3D time-of-flight) by using a 7T MRI system. Intensity inhomogeneity correction was performed using the “New Segment” module in SPM8 with four different values (120, 90, 60, and 30 mm) of full width at half maximum (FWHM) in Gaussian smoothness. The uniformity in signals in the entire white matter was evaluated using the coefficient of variation (CV); mean signal intensities between the subcortical and deep white matter were compared, and contrast between subcortical white matter and gray matter was measured. The length of the lenticulostriate (LSA) was measured on maximum intensity projection (MIP) images in the original and corrected images. Results: In all sequences, the CV decreased as the FWHM value decreased. The differences of mean signal intensities between subcortical and deep white matter also decreased with smaller FWHM values. The contrast between white and gray matter was maintained at all FWHM values. LSA length was significantly greater in corrected MIP than in the original MIP images. Conclusions: Intensity inhomogeneity in 7T MRI can be successfully corrected using SPM8 for various scan sequences

  6. Intensity inhomogeneity correction for magnetic resonance imaging of human brain at 7T.

    Science.gov (United States)

    Uwano, Ikuko; Kudo, Kohsuke; Yamashita, Fumio; Goodwin, Jonathan; Higuchi, Satomi; Ito, Kenji; Harada, Taisuke; Ogawa, Akira; Sasaki, Makoto

    2014-02-01

    To evaluate the performance and efficacy for intensity inhomogeneity correction of various sequences of the human brain in 7T MRI using the extended version of the unified segmentation algorithm. Ten healthy volunteers were scanned with four different sequences (2D spin echo [SE], 3D fast SE, 2D fast spoiled gradient echo, and 3D time-of-flight) by using a 7T MRI system. Intensity inhomogeneity correction was performed using the "New Segment" module in SPM8 with four different values (120, 90, 60, and 30 mm) of full width at half maximum (FWHM) in Gaussian smoothness. The uniformity in signals in the entire white matter was evaluated using the coefficient of variation (CV); mean signal intensities between the subcortical and deep white matter were compared, and contrast between subcortical white matter and gray matter was measured. The length of the lenticulostriate (LSA) was measured on maximum intensity projection (MIP) images in the original and corrected images. In all sequences, the CV decreased as the FWHM value decreased. The differences of mean signal intensities between subcortical and deep white matter also decreased with smaller FWHM values. The contrast between white and gray matter was maintained at all FWHM values. LSA length was significantly greater in corrected MIP than in the original MIP images. Intensity inhomogeneity in 7T MRI can be successfully corrected using SPM8 for various scan sequences.

  7. Increased T2 signal intensity in the distal clavicle: incidence and clinical implications

    International Nuclear Information System (INIS)

    Fiorella, D.; Helms, C.A.; Speer, K.P.

    2000-01-01

    Objective. The objectives of the current study were (1) to quantify the incidence of increased T2 signal in the distal clavicle and (2) to assess the clinical significance of this finding in patients with chronic acromioclavicular (AC) joint pain.Design and patients. Eight patients (five male and three female, 15-41 years of age) with disabling shoulder pain localized to the AC joint and marked increased T2 signal in the distal clavicle are presented. These eight patients underwent MR examination over a 25 month period (August 1996 to September 1998). The dictated reports of all shoulder MR examinations conducted over this same time period were reviewed retrospectively for the presence of signal abnormality in the distal cla-vicle. Clinical data and, in five patients, findings at shoulder arthroscopy or open surgery, were correlated with the results of MR imaging. One patient underwent arthroscopy on both shoulders.Results. The selected eight patients each presented clinically with disabling shoulder pain localized to the AC joint. One patient is presented twice, as both shoulders were symptomatic (n=9). Plain film examination (9/9) failed to indicate a structural cause of shoulder pain in any of the patients. MR examination demonstrated abnormally increased T2 signal in the distal clavicle in all nine cases and no other cause for AC joint pain. Three patients responded to a course of conservative therapy. Six experienced refractory pain despite conservative therapy. Resection of the distal clavicle was performed in five of the six cases. All patients who underwent resection of the distal clavicle experienced complete resolution of AC joint pain. A retrospective review of the dictated reports for all shoulder MR imaging examinations performed at out institution over a 25 month period (August 1996 to September 1998; n=761) demonstrated a 12.5% incidence of abnormally increased T2 signal in the distal clav-icle.Conclusions. Increased T2 signal in the distal clavicle

  8. Increased T2 signal intensity in the distal clavicle: incidence and clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Fiorella, D.; Helms, C.A. [Dept. of Radiology, Duke Univ., Durham, NC (United States); Speer, K.P. [Dept. of Orthopedic Surgery, Duke Univ., Durham, NC (United States)

    2000-12-01

    Objective. The objectives of the current study were (1) to quantify the incidence of increased T2 signal in the distal clavicle and (2) to assess the clinical significance of this finding in patients with chronic acromioclavicular (AC) joint pain.Design and patients. Eight patients (five male and three female, 15-41 years of age) with disabling shoulder pain localized to the AC joint and marked increased T2 signal in the distal clavicle are presented. These eight patients underwent MR examination over a 25 month period (August 1996 to September 1998). The dictated reports of all shoulder MR examinations conducted over this same time period were reviewed retrospectively for the presence of signal abnormality in the distal cla-vicle. Clinical data and, in five patients, findings at shoulder arthroscopy or open surgery, were correlated with the results of MR imaging. One patient underwent arthroscopy on both shoulders.Results. The selected eight patients each presented clinically with disabling shoulder pain localized to the AC joint. One patient is presented twice, as both shoulders were symptomatic (n=9). Plain film examination (9/9) failed to indicate a structural cause of shoulder pain in any of the patients. MR examination demonstrated abnormally increased T2 signal in the distal clavicle in all nine cases and no other cause for AC joint pain. Three patients responded to a course of conservative therapy. Six experienced refractory pain despite conservative therapy. Resection of the distal clavicle was performed in five of the six cases. All patients who underwent resection of the distal clavicle experienced complete resolution of AC joint pain. A retrospective review of the dictated reports for all shoulder MR imaging examinations performed at out institution over a 25 month period (August 1996 to September 1998; n=761) demonstrated a 12.5% incidence of abnormally increased T2 signal in the distal clav-icle.Conclusions. Increased T2 signal in the distal clavicle

  9. The nature of alarm communication in Constrictotermes cyphergaster (Blattodea: Termitoidea: Termitidae: the integration of chemical and vibroacoustic signals

    Directory of Open Access Journals (Sweden)

    Paulo F. Cristaldo

    2015-12-01

    Full Text Available Alarm signalling is of paramount importance to communication in all social insects. In termites, vibroacoustic and chemical alarm signalling are bound to operate synergistically but have never been studied simultaneously in a single species. Here, we inspected the functional significance of both communication channels in Constrictotermes cyphergaster (Termitidae: Nasutitermitinae, confirming the hypothesis that these are not exclusive, but rather complementary processes. In natural situations, the alarm predominantly attracts soldiers, which actively search for the source of a disturbance. Laboratory testing revealed that the frontal gland of soldiers produces a rich mixture of terpenoid compounds including an alarm pheromone. Extensive testing led to identification of the alarm pheromone being composed of abundant monoterpene hydrocarbons (1S-α-pinene and myrcene, along with a minor component, (E-β-ocimene. The vibratory alarm signalling consists of vibratory movements evidenced as bursts; a series of beats produced predominantly by soldiers. Exposing termite groups to various mixtures containing the alarm pheromone (crushed soldier heads, frontal gland extracts, mixture of all monoterpenes, and the alarm pheromone mixture made of standards resulted in significantly higher activity in the tested groups and also increased intensity of the vibratory alarm communication, with the responses clearly dose-dependent. Lower doses of the pheromone provoked higher numbers of vibratory signals compared to higher doses. Higher doses induced long-term running of all termites without stops necessary to perform vibratory behaviour. Surprisingly, even crushed worker heads led to low (but significant increases in the alarm responses, suggesting that other unknown compound in the worker's head is perceived and answered by termites. Our results demonstrate the existence of different alarm levels in termites, with lower levels being communicated through

  10. Increased signal intensity within glioblastoma resection cavities on fluid-attenuated inversion recovery imaging to detect early progressive disease in patients receiving radiotherapy with concomitant temozolomide therapy

    Energy Technology Data Exchange (ETDEWEB)

    Perry, Luke A. [Monash University, Melbourne (Australia); Korfiatis, Panagiotis; Erickson, Bradley J. [Mayo Clinic Rochester, Department of Radiology, Rochester, MN (United States); Agrawal, Jay P. [University of Massachusetts Medical School, Department of Radiology, Worcester, MA (United States)

    2018-01-15

    Our study tested the diagnostic accuracy of increased signal intensity (SI) within FLAIR MR images of resection cavities in differentiating early progressive disease (ePD) from pseudoprogression (PsP) in patients with glioblastoma treated with radiotherapy with concomitant temozolomide therapy. In this retrospective study approved by our Institutional Review Board, we evaluated the records of 122 consecutive patients with partially or totally resected glioblastoma. Region of interest (ROI) analysis assessed 33 MR examinations from 11 subjects with histologically confirmed ePD and 37 MR examinations from 14 subjects with PsP (5 histologically confirmed, 9 clinically diagnosed). After applying an N4 bias correction algorithm to remove B0 field distortion and to standardize image intensities and then normalizing the intensities based on an ROI of uninvolved white matter from the contralateral hemisphere, the mean intensities of the ROI from within the resection cavities were calculated. Measures of diagnostic performance were calculated from the receiver operating characteristic (ROC) curve using the threshold intensity that maximized differentiation. Subgroup analysis explored differences between the patients with biopsy-confirmed disease. At an optimal threshold intensity of 2.9, the area under the ROC curve (AUROC) for FLAIR to differentiate ePD from PsP was 0.79 (95% confidence interval 0.686-0.873) with a sensitivity of 0.818 and specificity of 0.694. The AUROC increased to 0.86 when only the patients with biopsy-confirmed PsP were considered. Increased SI within the resection cavity of FLAIR images is not a highly specific sign of ePD in glioblastoma patients treated with the Stupp protocol. (orig.)

  11. Signal characteristics of focal bone marrow lesions in patients with multiple myeloma using whole body T1w-TSE, T2w-STIR and diffusion-weighted imaging with background suppression

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Gregor; Bongartz, Georg; Winter, Leopold [University of Basel Hospital, Department of Radiology, Basel (Switzerland); Klarhoefer, Markus; Lenz, Claudia; Scheffler, Klaus [University of Basel Hospital, Department of Radiology, Division of Radiological Physics, Basel (Switzerland)

    2011-04-15

    This study analyses the diagnostic potential of Diffusion-Weighted Imaging with Background Suppression (DWIBS) in the detection of focal bone marrow lesions from multiple myeloma. The signal and contrast properties of DWIBS are evaluated in correlation with the serum concentration of M-component (MC) and compared with established T1- and T2-weighted sequences. Data from 103 consecutive studies in 81 patients are analysed retrospectively. Signal intensities and apparent Diffusion Coefficients (ADC) of 79 focal lesions in the lumbar spine or pelvis of 38 patients are determined and contrast-to-noise-ratio (CNR) is calculated. Data from patients with low (<20 g/L) and high (>20 g/dL) MC are evaluated separately. Signal intensities of focal myeloma lesions on T2w-STIR vary significantly depending on the MC, which leads to a loss in CNR in patients with high MC. No signal variation is observed for T1w-TSE and DWIBS. The CNR values provided by DWIBS in patients with high MC are slightly higher than those of T2w-STIR. ADC values in patients with low MC are significantly higher than in patients with high MC. Whole-body DWIBS has the potential to improve the conspicuity of focal myeloma lesions and provides additional biological information by ADC quantification. (orig.)

  12. Stat5 signaling specifies basal versus stress erythropoietic responses through distinct binary and graded dynamic modalities.

    Directory of Open Access Journals (Sweden)

    Ermelinda Porpiglia

    2012-08-01

    Full Text Available Erythropoietin (Epo-induced Stat5 phosphorylation (p-Stat5 is essential for both basal erythropoiesis and for its acceleration during hypoxic stress. A key challenge lies in understanding how Stat5 signaling elicits distinct functions during basal and stress erythropoiesis. Here we asked whether these distinct functions might be specified by the dynamic behavior of the Stat5 signal. We used flow cytometry to analyze Stat5 phosphorylation dynamics in primary erythropoietic tissue in vivo and in vitro, identifying two signaling modalities. In later (basophilic erythroblasts, Epo stimulation triggers a low intensity but decisive, binary (digital p-Stat5 signal. In early erythroblasts the binary signal is superseded by a high-intensity graded (analog p-Stat5 response. We elucidated the biological functions of binary and graded Stat5 signaling using the EpoR-HM mice, which express a "knocked-in" EpoR mutant lacking cytoplasmic phosphotyrosines. Strikingly, EpoR-HM mice are restricted to the binary signaling mode, which rescues these mice from fatal perinatal anemia by promoting binary survival decisions in erythroblasts. However, the absence of the graded p-Stat5 response in the EpoR-HM mice prevents them from accelerating red cell production in response to stress, including a failure to upregulate the transferrin receptor, which we show is a novel stress target. We found that Stat5 protein levels decline with erythroblast differentiation, governing the transition from high-intensity graded signaling in early erythroblasts to low-intensity binary signaling in later erythroblasts. Thus, using exogenous Stat5, we converted later erythroblasts into high-intensity graded signal transducers capable of eliciting a downstream stress response. Unlike the Stat5 protein, EpoR expression in erythroblasts does not limit the Stat5 signaling response, a non-Michaelian paradigm with therapeutic implications in myeloproliferative disease. Our findings show how the

  13. Tune measurements with high intensity ion beams at GSI SIS-18

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Rahul [GSI, Darmstadt (Germany); TEMF, TU Darmstadt (Germany); Forck, Peter; Kowina, Piotr; Kaufmann, Wolfgang [GSI, Darmstadt (Germany); Weiland, Thomas [TEMF, TU Darmstadt (Germany)

    2012-07-01

    A precise tune measurement during a full accelerating cycle is required to achieve stable high current operation. A new system has been commissioned at GSI for position, orbit and tune measurements. It consists of three distinct parts; an exciter which provides power to excite coherent betatron oscillations in the bunched beam; Fast ADCs to digitize the BPM signals at 125 MSa/s; the post processing electronics uses digitized BPM signals to acquire one position value per bunch. Subsequently the baseband tune is determined by Fourier transformation of the position data. Experiments were conducted to understand the effects of high beam intensity on tune at injection plateau (11.4 MeV/u) and during acceleration ramp (11.4-600 MeV/u). These experiments were performed with U{sup 73+} and Ar{sup 18+} ion beam at highest achievable intensities of 2.10{sup 9} and 2.5.10{sup 10} respectively. Tune shift with increased intensity was observed. The working principle of the tune measurement system and observed high intensity effects on tune will be reported in this contribution.

  14. Signal intensity and T2 time of extraocular muscles in assessment of their physiological status in MR imaging in healthy subjects

    International Nuclear Information System (INIS)

    Pająk, Michał; Loba, Piotr; Wieczorek-Pastusiak, Julia; Antosik-Biernacka, Aneta; Stefańczyk, Ludomir; Majos, Agata

    2012-01-01

    Lack of standardised orbital MR protocols leads to a situation, when each institution/centre may arbitrarily choose sequence parameters. Therefore, the results obtained and published by the authors may not be compared freely, and what is most important may not be considered fully reliable. Signal intensity (IS) and T2 time (T2) are important parameters in estimation of inflammatory processes of extraocular muscles in the clinical practice. The aim of this study was to determine the reference values (i.e. cut-off values) for absolute signal intensity and T2 relaxation time in healthy subjects, their relativised values to white matter (WM) and temporal muscles (TM) and to evaluate the correlation between those parameters. The orbital examination was performed in healthy volunteers according to the protocol prepared in the Radiology-Imaging Diagnostic Department of the Medical University of Lodz for patients with suspected/diagnosed thyroid orbitopathy. Using two of the standard sequences IS and T2 time were calculated for the muscles and two relativisation tissues in realtion to WM and TM. Subsequently cut-off values for healthy volunteers were calculated. The differences between muscles for IS, IS MAX, IS/TM, IS/WM, IS MAX/TM, IS MAX/WM and T2 MAX/WM were not statistically significant. Therefore one cut-off value of these parameters for all the rectus muscles was calculated. T2-relaxation time and T2 relativised to white matter had to be calculated separately for each muscle. No statistical correlation was found between IS and T2-time for extraocular muscles in healthy volunteers. We calculated the reference ranges (cut-off values) for absolute IS and T2-time values and relativised parameters. In the clinical practice the objectification of IS and T2-time values should be done to WM, than to IS or T2 of the temporal muscle. The T2 MAX/WM seems to have the highest clinical utility for the assessment of the pathophysiological status of extraocular muscles

  15. Intensive meditation for refractory pain and symptoms.

    Science.gov (United States)

    Goyal, Madhav; Haythornthwaite, Jennifer; Levine, David; Becker, Diane; Vaidya, Dhananjay; Hill-Briggs, Felicia; Ford, Daniel

    2010-06-01

    The objective of this study was to assess patient interest in intensive meditation training for chronic symptoms. This was a cross-sectional anonymous survey among six chronic disease clinics in Baltimore including Chronic Kidney Disease, Crohn's Disease, Headache, Renal Transplant Recipients, General Rheumatology, and lupus clinic. Subjects were 1119 consecutive patients registering for their appointments at these clinics. Outcome measures were 6-month pain, global symptomatology, four-item perceived stress scale, use of complementary and alternative medicine (CAM) therapies, and attitudes toward use of meditation for managing symptoms. We then gave a scripted description of an intensive, 10-day meditation training retreat. Patient interest in attending such a retreat was assessed. Seventy-seven percent (77%) of patients approached completed the survey. Fifty-three percent (53%) of patients reported moderate to severe pain over the past 6 months. Eighty percent (80%) reported use of some CAM therapy in the past. Thirty-five percent (35%) thought that learning meditation would improve their health, and 49% thought it would reduce stress. Overall, 39% reported interest in attending the intensive 10-day meditation retreat. Among those reporting moderate to severe pain or stress, the percentages were higher (48% and 59%). In a univariate analysis, higher education, nonworking/disabled status, female gender, higher stress, higher pain, higher symptomatology, and any CAM use were all associated with a greater odds of being moderately to very interested in an intensive 10-day meditation retreat. A multivariate model that included prior use of CAM therapies as predictors of interest in the program fit the data significantly better than a model not including CAM therapies (p = 0.0013). Over 50% of patients followed in chronic disease clinics complain of moderate to severe pain. Patients with persistent pain or stress are more likely to be interested in intensive meditation.

  16. The effect of age and disease on the MR imaging T2 low signal intensity area in the cerebral cortex

    International Nuclear Information System (INIS)

    Imon, Yukari; Yamaguchi, Shinya; Katayama, Sadao; Harada, Akira; Yamamura, Yasuhiro; Nakamura, Shigenobu

    1994-01-01

    We retrospectively studied magnetic resonance (MR) images of the brain in 139 patients (16 cases of Alzheimer's disease, 8 cases of Parkinson's disease, 53 cases of multiple cerebral infarct, 33 cases of other central nervous diseases, and 29 cases of peripheral neuropathy) between the age of 6 and 85 years old with a mean age of 60.6±18.5 to examine the appearance of T2 low signal intensity areas (T 2 -CLIA) in the cerebral cortex. Motor, occipital, sensory or other cortices were evaluated with long repetition time/echo time (TR/TE) spin-echo sequences and staged into three grades in the motor cortex: none, partial, and whole; and two grades in the other: none or present. In general, T 2 -CLIA was not seen in any cortex in patients less than 50 years old, then after 50 years old T 2 -CLIA increased with age. Over 70 years of age T 2 -CLIA appeared in 50.9% of patients in the whole motor cortex, 88.7% in either whole or partial motor cortex, 47.2% in the occipital cortex, and 20.8% in the sensory cortex. T 2 -CLIA was not observed in other cortices. The incidence of T 2 -CLIA appearance in the motor cortex was significantly higher in all central nervous diseases than in cases of peripheral neuropathy over 70. T 2 -CLIA showed a correlation with temporal lobe atrophy and white matter lesions in the motor cortex. In the sensory cortex, T 2 -CLIA correlated with white matter lesions. These results suggest that T 2 -CLIA may correlate with age or accumulation of nonheme iron in the cortex associated with central nervous diseases. (author)

  17. The effect of age and disease on the MR imaging T2 low signal intensity area in the cerebral cortex

    Energy Technology Data Exchange (ETDEWEB)

    Imon, Yukari; Yamaguchi, Shinya; Katayama, Sadao; Harada, Akira; Yamamura, Yasuhiro; Nakamura, Shigenobu (Hiroshima Univ. (Japan). School of Medicine)

    1994-09-01

    We retrospectively studied magnetic resonance (MR) images of the brain in 139 patients (16 cases of Alzheimer's disease, 8 cases of Parkinson's disease, 53 cases of multiple cerebral infarct, 33 cases of other central nervous diseases, and 29 cases of peripheral neuropathy) between the age of 6 and 85 years old with a mean age of 60.6[+-]18.5 to examine the appearance of T2 low signal intensity areas (T[sub 2]-CLIA) in the cerebral cortex. Motor, occipital, sensory or other cortices were evaluated with long repetition time/echo time (TR/TE) spin-echo sequences and staged into three grades in the motor cortex: none, partial, and whole; and two grades in the other: none or present. In general, T[sub 2]-CLIA was not seen in any cortex in patients less than 50 years old, then after 50 years old T[sub 2]-CLIA increased with age. Over 70 years of age T[sub 2]-CLIA appeared in 50.9% of patients in the whole motor cortex, 88.7% in either whole or partial motor cortex, 47.2% in the occipital cortex, and 20.8% in the sensory cortex. T[sub 2]-CLIA was not observed in other cortices. The incidence of T[sub 2]-CLIA appearance in the motor cortex was significantly higher in all central nervous diseases than in cases of peripheral neuropathy over 70. T[sub 2]-CLIA showed a correlation with temporal lobe atrophy and white matter lesions in the motor cortex. In the sensory cortex, T[sub 2]-CLIA correlated with white matter lesions. These results suggest that T[sub 2]-CLIA may correlate with age or accumulation of nonheme iron in the cortex associated with central nervous diseases. (author).

  18. The effect of age and disease on the MR imaging T2 low signal intensity area in the cerebral cortex

    Energy Technology Data Exchange (ETDEWEB)

    Imon, Yukari; Yamaguchi, Shinya; Katayama, Sadao; Harada, Akira; Yamamura, Yasuhiro; Nakamura, Shigenobu [Hiroshima Univ. (Japan). School of Medicine

    1994-09-01

    We retrospectively studied magnetic resonance (MR) images of the brain in 139 patients (16 cases of Alzheimer's disease, 8 cases of Parkinson's disease, 53 cases of multiple cerebral infarct, 33 cases of other central nervous diseases, and 29 cases of peripheral neuropathy) between the age of 6 and 85 years old with a mean age of 60.6[+-]18.5 to examine the appearance of T2 low signal intensity areas (T[sub 2]-CLIA) in the cerebral cortex. Motor, occipital, sensory or other cortices were evaluated with long repetition time/echo time (TR/TE) spin-echo sequences and staged into three grades in the motor cortex: none, partial, and whole; and two grades in the other: none or present. In general, T[sub 2]-CLIA was not seen in any cortex in patients less than 50 years old, then after 50 years old T[sub 2]-CLIA increased with age. Over 70 years of age T[sub 2]-CLIA appeared in 50.9% of patients in the whole motor cortex, 88.7% in either whole or partial motor cortex, 47.2% in the occipital cortex, and 20.8% in the sensory cortex. T[sub 2]-CLIA was not observed in other cortices. The incidence of T[sub 2]-CLIA appearance in the motor cortex was significantly higher in all central nervous diseases than in cases of peripheral neuropathy over 70. T[sub 2]-CLIA showed a correlation with temporal lobe atrophy and white matter lesions in the motor cortex. In the sensory cortex, T[sub 2]-CLIA correlated with white matter lesions. These results suggest that T[sub 2]-CLIA may correlate with age or accumulation of nonheme iron in the cortex associated with central nervous diseases. (author).

  19. The application of radiation-induced free radicals signals in retrospective dosimetry

    International Nuclear Information System (INIS)

    Liu Zhongchao; Zhang Wenyi; Jiao Ling

    2013-01-01

    For some materials and biological samples, free radicals can be induced after ionizing radiation. Electron spin resonance (ESR) spectroscopy can detect free radical signal and its intensity can reflect the dose of the ionizing radiation. It is a typical way to estimate the radiation dosimetry by using the ESR spectroscopy of teeth. In recent years, many researchers studied on ESR of easy-getting materials such as finger (toe) nail, hair, cell phone screen, in order to investigate the relationship between signal intensity and radiation dose. The aim of this paper is to survey the current literature about methodologies and the materials on background signal, linearity of dose-response relationship, minimum detection limit and post-irradiation signal stability, so that more data will be provided for nuclear accident dose estimation. (authors)

  20. Plant monitoring and signal validation at HFIR

    International Nuclear Information System (INIS)

    Mullens, J.A.

    1991-01-01

    This paper describes a monitoring system for the Oak Ridge National Laboratory's (ORNL'S) High Flux Isotope Reactor (HFIR). HFIR is an 85 MW pressurized water reactor designed to produce isotopes and intense neutron beams. The monitoring system is described with respect to plant signals and computer system; monitoring overview; data acquisition, logging and network distribution; signal validation; status displays; reactor condition monitoring; reactor operator aids. Future work will include the addition of more plant signals, more signal validation and diagnostic capabilities, improved status display, integration of the system with the RELAP plant simulation and graphical interface, improved operator aids, and an alarm filtering system. 8 refs., 7 figs. (MB)

  1. Influence of Signal and Noise on Statistical Fluctuation of Single-Mode Laser System

    International Nuclear Information System (INIS)

    Xu Dahai; Cheng Qinghua; Cao Li; Wu Dajin

    2006-01-01

    On the basis of calculating the steady-state mean normalized intensity fluctuation of a signal-mode laser system driven by both colored pump noise with signal modulation and the quantum noise with cross-correlation between its real and imaginary parts, we analyze the influence of modulation signal, noise, and its correlation form on the statistical fluctuation of the laser system. We have found that when the amplitude of modulation signal weakens and its frequency quickens, the statistical fluctuation will reduce rapidly. The statistical fluctuation of the laser system can be restrained by reducing the intensity of pump noise and quantum noise. Moreover, with prolonging of colored cross-correlation time, the statistical fluctuation of laser system experiences a repeated changing process, that is, from decreasing to augmenting, then to decreasing, and finally to augmenting again. With the decreasing of the value of cross-correlation coefficient, the statistical fluctuation will decrease too. When the cross-correlation form between the real part and imaginary part of quantum noise is zero correlation, the statistical fluctuation of laser system has a minimum. Compared with the influence of intensity of pump noise, the influence of intensity of quantum noise on the statistical fluctuation is smaller.

  2. On the Capacity of the Intensity-Modulation Direct-Detection Optical Broadcast Channel

    KAUST Repository

    Chaaban, Anas

    2016-01-12

    The capacity of the intensity-modulation directdetection optical broadcast channel (OBC) is investigated, under both average and peak intensity constraints. An outer bound on the capacity region is derived by adapting Bergmans’ approach to the OBC. Inner bounds are derived by using superposition coding with either truncated-Gaussian (TG) distributions or discrete distributions. While the discrete distribution achieves higher rates, the TG distribution leads to a simpler representation of the achievable rate region. At high signal-to-noise ratio (SNR), it is shown that the TG distribution is nearly optimal. It achieves the symmetric-capacity within a constant gap (independent of SNR), which approaches half a bit as the number of users grows. It also achieves the capacity region within a constant gap. At low SNR, it is shown that on-off keying (OOK) with time-division multipleaccess (TDMA) is optimal. This is interesting in practice since both OOK and TDMA have low complexity. At moderate SNR (typically [0,8] dB), a discrete distribution with a small alphabet size achieves fairly good performance.

  3. On the Capacity of the Intensity-Modulation Direct-Detection Optical Broadcast Channel

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2016-01-01

    The capacity of the intensity-modulation directdetection optical broadcast channel (OBC) is investigated, under both average and peak intensity constraints. An outer bound on the capacity region is derived by adapting Bergmans’ approach to the OBC. Inner bounds are derived by using superposition coding with either truncated-Gaussian (TG) distributions or discrete distributions. While the discrete distribution achieves higher rates, the TG distribution leads to a simpler representation of the achievable rate region. At high signal-to-noise ratio (SNR), it is shown that the TG distribution is nearly optimal. It achieves the symmetric-capacity within a constant gap (independent of SNR), which approaches half a bit as the number of users grows. It also achieves the capacity region within a constant gap. At low SNR, it is shown that on-off keying (OOK) with time-division multipleaccess (TDMA) is optimal. This is interesting in practice since both OOK and TDMA have low complexity. At moderate SNR (typically [0,8] dB), a discrete distribution with a small alphabet size achieves fairly good performance.

  4. Macroseismic intensity attenuation in Iran

    Science.gov (United States)

    Yaghmaei-Sabegh, Saman

    2018-01-01

    Macroseismic intensity data plays an important role in the process of seismic hazard analysis as well in developing of reliable earthquake loss models. This paper presents a physical-based model to predict macroseismic intensity attenuation based on 560 intensity data obtained in Iran in the time period 1975-2013. The geometric spreading and energy absorption of seismic waves have been considered in the proposed model. The proposed easy to implement relation describes the intensity simply as a function of moment magnitude, source to site distance and focal depth. The prediction capability of the proposed model is assessed by means of residuals analysis. Prediction results have been compared with those of other intensity prediction models for Italy, Turkey, Iran and central Asia. The results indicate the higher attenuation rate for the study area in distances less than 70km.

  5. Signal effects of various radiographic contrast media and their interaction with gadolinium DTPA during MRT

    International Nuclear Information System (INIS)

    Kopka, L.; Funke, M.; Fischer, U.; Vosshenrich, R.; Schroeder, M.; Grabbe, E.

    1994-01-01

    T 1 and T 2 weighted signals dereived from various radiological contrast media were studied during MRT spin-echo sequences. In addition, the interaction between radiological contrast media and Gadolinium-DTPA concerning T 1 signals was evaluated. Ionic (ioxitalaminic acid) and non-ionic radiological contrast media (Iopromid, Iotrolan) were used in diagnostic concentrations. Measurements were carried out with a superconductive magnet of 1.5 Tesla. Radiological contrast media produced significantly higher signals than a physiological sodium chloride solution in T 1 -weighted spin-echo sequences. Evn small amounts (15% of total volume) of radiological contrast media during T 1 -weighted spin-echo sequences led to a significant reduction (about 25%) of the signal intensity of a 2 mM Gadolinium-DTPA solution. This may lead to diagnostic problems, as was shown in a series of 25 MR arthrograms of the shoulder. It is recommended than an interval of at least 6 hours should elapse between the use of a radiological contrst medium and an MRT examination. (orig.) [de

  6. Steganography based on pixel intensity value decomposition

    Science.gov (United States)

    Abdulla, Alan Anwar; Sellahewa, Harin; Jassim, Sabah A.

    2014-05-01

    This paper focuses on steganography based on pixel intensity value decomposition. A number of existing schemes such as binary, Fibonacci, Prime, Natural, Lucas, and Catalan-Fibonacci (CF) are evaluated in terms of payload capacity and stego quality. A new technique based on a specific representation is proposed to decompose pixel intensity values into 16 (virtual) bit-planes suitable for embedding purposes. The proposed decomposition has a desirable property whereby the sum of all bit-planes does not exceed the maximum pixel intensity value, i.e. 255. Experimental results demonstrate that the proposed technique offers an effective compromise between payload capacity and stego quality of existing embedding techniques based on pixel intensity value decomposition. Its capacity is equal to that of binary and Lucas, while it offers a higher capacity than Fibonacci, Prime, Natural, and CF when the secret bits are embedded in 1st Least Significant Bit (LSB). When the secret bits are embedded in higher bit-planes, i.e., 2nd LSB to 8th Most Significant Bit (MSB), the proposed scheme has more capacity than Natural numbers based embedding. However, from the 6th bit-plane onwards, the proposed scheme offers better stego quality. In general, the proposed decomposition scheme has less effect in terms of quality on pixel value when compared to most existing pixel intensity value decomposition techniques when embedding messages in higher bit-planes.

  7. Covert Sexual Signaling: Human Flirtation and Implications for other Social Species

    Directory of Open Access Journals (Sweden)

    Andrew Gersick

    2014-07-01

    Full Text Available According to signaling theory and a large body of supporting evidence, males across many taxa produce courtship signals that honestly advertise their quality. The cost of producing or performing these signals maintains signal honesty, such that females are typically able to choose the best males by selecting those that produce the loudest, brightest, longest, or otherwise highest-intensity signals, using signal strength as a measure of quality. Set against this background, human flirting behavior, characterized by its frequent subtlety or covertness, is mysterious. Here we propose that the explanation for subtle and ambiguous signals in human courtship lies in socially imposed costs that (a vary with social context and (b are amplified by the unusual ways in which language makes all interactions potentially public. Flirting is a class of courtship signaling that conveys the signaler's intentions and desirability to the intended receiver while minimizing the costs that would accompany an overt courtship attempt. This proposal explains humans' taxonomically unusual courtship displays and generates a number of novel predictions for both humans and non-human social animals. Individuals who are courting should vary the intensity of their signals to suit the level of risk attached to the particular social configuration, and receivers may assess this flexible matching of signal to context as an indicator of the signaler's broader behavioral flexibility and social intelligence.

  8. [Intensity of depression in pedagogy students].

    Science.gov (United States)

    Pietras, Tadeusz; Witusik, Andrzej; Panek, Michał; Zielińska-Wyderkiewicz, Ewa; Kuna, Piotr; Górski, Paweł

    2012-03-01

    The teacher's profession is regarded to be susceptible to professional burnout. Its early markers include high neuroticism and tendency to depressive reactions. The aim of the study was to assess the depression intensity and the occurrence of mood disorders in the population of full-time and extramural course students of pedagogy aged 19-30, as well as the difference in intensity of the measured constructs between men and women. The study was carried out on the group of 223 women and 162 men aged 19-30 studying pedagogy at Piotrków Trybunalski Division of Jan Kochanowski Memorial University in Kielce in the years 2008-2011. The control group consisted of 76 women and 88 men studying economics. Students of full-time and extramural courses were included. All the participants were assessed with Beck Depression Inventory. Depression as a syndrome was diagnosed if the score of 10 of more was obtained. Among female students of pedagogy, 21 out of 223 obtained Beck Depression Inventory scores equal to, or above 10; whereas among female students of economics 1 out of 76 obtained such a result. The relative risk of developing depression (understood as Beck Depression Inventory result of 10 or more) was found to be significantly higher among female pedagogues (OR 7.797; CI 1.0306 to 58.9856) than among female economists. Among male pedagogy students, 2 out of 162 obtained 10 points, or more. It means that the risk of depression in female pedagogues was as much as over eight-fold higher than in male pedagogues (OR 8.3168; CI 1.9215 - 35.9979). The risk of depression in men studying pedagogy was not higher than in men studying economics, who obtained the Beck Depression Inventory scores of 10 or more in 1 case out of 88 (OR 1.1; CI 0.0983 to 12.3032). Considering all pedagogues irrespectively of gender versus all economists, the risk of depression in the group of pedagogues is over five-fold higher than among economists (OR 5.1464; CI 1.1991 to 22.0885). In the whole group of

  9. Accurate signal reconstruction for higher order Lagrangian–Eulerian back-coupling in multiphase turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Zwick, D; Balachandar, S [Department of Mechanical and Aerospace Engineering, University of Florida, FL, United States of America (United States); Sakhaee, E; Entezari, A, E-mail: dpzwick@ufl.edu [Department of Computer and Information Science and Engineering, University of Florida, FL, United States of America (United States)

    2017-10-15

    Multiphase flow simulation serves a vital purpose in applications as diverse as engineering design, natural disaster prediction, and even study of astrophysical phenomena. In these scenarios, it can be very difficult, expensive, or even impossible to fully represent the physical system under consideration. Even still, many such real-world applications can be modeled as a two-phase flow containing both continuous and dispersed phases. Consequentially, the continuous phase is thought of as a fluid and the dispersed phase as particles. The continuous phase is typically treated in the Eulerian frame of reference and represented on a fixed grid, while the dispersed phase is treated in the Lagrangian frame and represented by a sample distribution of Lagrangian particles that approximate a cloud. Coupling between the phases requires interpolation of the continuous phase properties at the locations of the Lagrangian particles. This interpolation step is straightforward and can be performed at higher order accuracy. The reverse process of projecting the Lagrangian particle properties from the sample points to the Eulerian grid is complicated by the time-dependent non-uniform distribution of the Lagrangian particles. In this paper we numerically examine three reconstruction, or projection, methods: (i) direct summation (DS), (ii) least-squares, and (iii) sparse approximation. We choose a continuous representation of the dispersed phase property that is systematically varied from a simple single mode periodic signal to a more complex artificially constructed turbulent signal to see how each method performs in reconstruction. In these experiments, we show that there is a link between the number of dispersed Lagrangian sample points and the number of structured grid points to accurately represent the underlying functional representation to machine accuracy. The least-squares method outperforms the other methods in most cases, while the sparse approximation method is able to

  10. Signal intensity analysis and optimization for in vivo imaging of Cherenkov and excited luminescence

    Science.gov (United States)

    LaRochelle, Ethan P. M.; Shell, Jennifer R.; Gunn, Jason R.; Davis, Scott C.; Pogue, Brian W.

    2018-04-01

    During external beam radiotherapy (EBRT), in vivo Cherenkov optical emissions can be used as a dosimetry tool or to excite luminescence, termed Cherenkov-excited luminescence (CEL) with microsecond-level time-gated cameras. The goal of this work was to develop a complete theoretical foundation for the detectable signal strength, in order to provide guidance on optimization of the limits of detection and how to optimize near real time imaging. The key parameters affecting photon production, propagation and detection were considered and experimental validation with both tissue phantoms and a murine model are shown. Both the theoretical analysis and experimental data indicate that the detection level is near a single photon-per-pixel for the detection geometry and frame rates commonly used, with the strongest factor being the signal decrease with the square of distance from tissue to camera. Experimental data demonstrates how the SNR improves with increasing integration time, but only up to the point where the dominance of camera read noise is overcome by stray photon noise that cannot be suppressed. For the current camera in a fixed geometry, the signal to background ratio limits the detection of light signals, and the observed in vivo Cherenkov emission is on the order of 100×  stronger than CEL signals. As a result, imaging signals from depths  <15 mm is reasonable for Cherenkov light, and depths  <3 mm is reasonable for CEL imaging. The current investigation modeled Cherenkov and CEL imaging of two oxygen sensing phosphorescent compounds, but the modularity of the code allows for easy comparison of different agents or alternative cameras, geometries or tissues.

  11. Multi-Functional Sensor System for Heart Rate, Body Position and Movement Intensity Analysis

    Directory of Open Access Journals (Sweden)

    Michael MAO

    2008-12-01

    Full Text Available A novel multi-functional wearable sensor has been developed with multi-axis accelerometer, disposable hydro-gel electrodes, and analog filtering components. This novel sensor implementation can be used for detecting common body positions, movement intensity, and measures bio-potential signals for ECG and heart rate analysis. Based on the novel sensor principle, a prototype combines position detection, heart rate detection, and motion intensity level detection together in a handheld device that records the physiological information and wirelessly transmits the signals through Bluetooth to a mobile phone. Static body positions such as standing/sitting, lying supine, prone, and on the sides have been detected with high accuracy (97.7 % during the subject tests. Further, an algorithm that detects body movement intensity that can potentially be applied in real-time monitoring physical activity level is proposed based on average variance values. Motion intensity results show variance values increase and exercise intensity increases for almost all of the cases. A clear relation between movement intensity level shown by an increase in frequency and/or speed of exercise increases the variance values detected in all three spatial axes.

  12. Signal processing for the profoundly deaf.

    Science.gov (United States)

    Boothyroyd, A

    1990-01-01

    Profound deafness, defined here as a hearing loss in excess of 90 dB, is characterized by high thresholds, reduced hearing range in the intensity and frequency domains, and poor resolution in the frequency and time domains. The high thresholds call for hearing aids with unusually high gains or remote microphones that can be placed close to the signal source. The former option creates acoustic feedback problems for which digital signal processing may yet offer solutions. The latter option calls for carrier wave technology that is already available. The reduced frequency and intensity ranges would appear to call for frequency and/or amplitude compression. It might also be argued, however, that any attempts to compress the acoustic signal into the limited hearing range of the profoundly deaf will be counterproductive because of poor frequency and time resolution, especially when the signal is present in noise. In experiments with a 2-channel compression system, only 1 of 9 subjects showed an improvement of perception with the introduction of fast-release (20 ms) compression. The other 8 experienced no benefit or a slight deterioration of performance. These results support the concept of providing the profoundly deaf with simpler, rather than more complex, patterns, perhaps through the use of feature extraction hearing aids. Data from users of cochlear implants already employing feature extraction techniques also support this concept.

  13. Acute Impact of Moderate-Intensity and Vigorous-Intensity Exercise Bouts on Daily Physical Activity Energy Expenditure in Postmenopausal Women

    Directory of Open Access Journals (Sweden)

    Xuewen Wang

    2011-01-01

    Full Text Available This study determined whether performing a single moderate- or vigorous-intensity exercise bout impacts daily physical activity energy expenditure (PAEE, by accelerometer. Overweight/obese postmenopausal women underwent a 5-month caloric restriction and moderate- (n=18 or vigorous-intensity (n=18 center-based aerobic exercise intervention. During the last month of intervention, in women performing moderate-intensity exercise, PAEE on days with exercise (577.7±219.7 kcal⋅d−1 was higher (P=.011 than on days without exercise (450.7±140.5 kcal⋅d−1; however, the difference (127.0±188.1 kcal⋅d−1 was much lower than the energy expended during exercise. In women performing vigorous-intensity exercise, PAEE on days with exercise (450.6±153.6 kcal⋅d−1 was lower (P=.047 than on days without exercise (519.2±127.4 kcal⋅d−1. Thus, women expended more energy on physical activities outside of prescribed exercise on days they did NOT perform center-based exercise, especially if the prescribed exercise was of a higher intensity.

  14. Poisson pre-processing of nonstationary photonic signals: Signals with equality between mean and variance.

    Science.gov (United States)

    Poplová, Michaela; Sovka, Pavel; Cifra, Michal

    2017-01-01

    Photonic signals are broadly exploited in communication and sensing and they typically exhibit Poisson-like statistics. In a common scenario where the intensity of the photonic signals is low and one needs to remove a nonstationary trend of the signals for any further analysis, one faces an obstacle: due to the dependence between the mean and variance typical for a Poisson-like process, information about the trend remains in the variance even after the trend has been subtracted, possibly yielding artifactual results in further analyses. Commonly available detrending or normalizing methods cannot cope with this issue. To alleviate this issue we developed a suitable pre-processing method for the signals that originate from a Poisson-like process. In this paper, a Poisson pre-processing method for nonstationary time series with Poisson distribution is developed and tested on computer-generated model data and experimental data of chemiluminescence from human neutrophils and mung seeds. The presented method transforms a nonstationary Poisson signal into a stationary signal with a Poisson distribution while preserving the type of photocount distribution and phase-space structure of the signal. The importance of the suggested pre-processing method is shown in Fano factor and Hurst exponent analysis of both computer-generated model signals and experimental photonic signals. It is demonstrated that our pre-processing method is superior to standard detrending-based methods whenever further signal analysis is sensitive to variance of the signal.

  15. Comparing signal intensity and refraction sensitivity of double and single mask edge illumination lab-based x-ray phase contrast imaging set-ups

    International Nuclear Information System (INIS)

    Kallon, G K; Diemoz, P C; Vittoria, F A; Basta, D; Endrizzi, M; Olivo, A

    2017-01-01

    Double mask edge illumination (DM-EI) set-ups can detect differential phase and attenuation information from a sample. However, analytical separation of the two signals often requires acquiring two frames with inverted differential phase contrast signals. Typically, between these two acquisitions, the first mask is moved to create a different illumination condition. This can lead to potential errors which adversely affect the data collected. In this paper, we implement a single mask EI laboratory set-up that allows for a single shot retrieval of the differential phase and attenuation images, without the need for a high resolution detector or high magnification. As well as simplifying mask alignment, the advantages of the proposed set-up can be exploited in one of two ways: either the total acquisition time can be halved with respect to the DM-EI set-up or, for the same acquisition time, twice the statistics can be collected. In this latter configuration, the signal-to-noise ratio and contrast in the mixed intensity images, and the angular sensitivity of the two set-ups were compared. We also show that the angular sensitivity of the single mask set-up can be well approximated from its illumination curve, which has been modelled as a convolution between the source spatial distribution at the detector plane, the pre-sample mask and the detector point spread function (PSF). A polychromatic wave optics simulation was developed on these bases and benchmarked against experimental data. It can also be used to predict the angular sensitivity and contrast of any set-up as a function of detector PSF. (paper)

  16. Evidence for the Higher Importance of Signal Size Over Body Size in Aposematic Signaling in Insects

    OpenAIRE

    Remmel, Triinu; Tammarub, Toomas

    2011-01-01

    To understand the evolution of warning coloration, it is important to distinguish between different aspects of conspicuous color patterns. As an example, both pattern element size and body size of prey have been shown to enhance the effectiveness of warning signals. However, it is unclear whether the effect of body size is merely a side effect of proportionally increasing pattern elements, or if there is an effect of body size per se. These possibilities were evaluated by offering different s...

  17. Signal intensity change on unenhanced T1-weighted images in dentate nucleus following gadobenate dimeglumine in patients with and without previous multiple administrations of gadodiamide

    Energy Technology Data Exchange (ETDEWEB)

    Ramalho, Joana [University of North Carolina Hospital, Chapel Hill, NC (United States); Centro Hospitalar de Lisboa Central, Lisbon (Portugal); Semelka, Richard C.; Castillo, Mauricio [University of North Carolina Hospital, Chapel Hill, NC (United States); AlObaidy, Mamdoh [University of North Carolina Hospital, Chapel Hill, NC (United States); King Faisal Specialist Hospital and Research Center, Riyadh (Saudi Arabia); Ramalho, Miguel [University of North Carolina Hospital, Chapel Hill, NC (United States); Hospital Garcia de Orta, Almada (Portugal); Nunes, Renato H. [University of North Carolina Hospital, Chapel Hill, NC (United States); Santa Casa de Misericordia de Sao Paulo, Sao Paulo (Brazil)

    2016-11-15

    To evaluate the impact of previous administration of gadodiamide and neural tissue gadolinium deposition in patients who received gadobenate dimeglumine. Our population included 62 patients who underwent at least three administrations of gadobenate dimeglumine, plus an additional contrast-enhanced last MRI for reference, divided into two groups: group 1, patients who in addition to gadobenate dimeglumine administrations had prior exposure to multiple doses of gadodiamide; group 2, patients without previous exposure to other gadolinium-based contrast agent (GBCAs). Quantitative analysis was performed on the first and last gadobenate dimeglumine MRIs in both groups. Dentate nucleus-to-middle cerebellar peduncle signal intensity ratios (DN/MCP) and relative change (RC) in signal over time were calculated and compared between groups using generalized additive model. Group 1 showed significant increase in baseline and follow-up DN/MCP compared to group 2 (p < 0.0001). The RC DN/MCP showed a non-statistically significant trend towards an increase in patients who underwent previous gadodiamide (p = 0.0735). There is increased T1 signal change over time in patients who underwent gadobenate dimeglumine and had received prior gadodiamide compared to those without known exposure to previous gadodiamide. A potentiating effect from prior gadodiamide on subsequent administered gadobenate dimeglumine may occur. (orig.)

  18. XUV pulse effect on signal modulations of harmonic spectra from H2+ and T2+

    Science.gov (United States)

    Feng, Liqiang; Liu, Hang; Kapteyn, Henry J.; Feng, April Y.

    2018-05-01

    The effects of signal modulations on the molecular high-order harmonic generations in H2^{+ } and T2+ have been theoretically investigated. It is found that with the introduction of the XUV pulse, due to the absorption of the extra XUV photons in the recombination process, multiplateaus on the harmonic spectra, separated by the XUV photon energy can be found. Moreover, this multiplateau structure is insensitive to the wavelength of the XUV pulse. In shorter pulse duration, the intensities of the multiplateaus from H2+ are higher than those from T2+; while in longer pulse duration, the opposite results can be found. Finally, by changing the delay time of the XUV pulse, the signal modulations (including the amplitude and the frequency modulations) of the multiplateaus can be controlled.

  19. Intensive monitoring of new drugs based on first prescription signals from pharmacists : a pilot study

    NARCIS (Netherlands)

    Van Grootheest, AC; Groote, JK; de Jong-van den Berg, LTW

    Background Intensive monitoring can be a valuable tool in the early detection of adverse drug reactions, especially of new drugs. Aim of this pilot study was to investigate the practical possibilities of a system of intensive monitoring, using the pharmacy computer system to detect the first

  20. Reducing false asystole alarms in intensive care.

    Science.gov (United States)

    Dekimpe, Remi; Heldt, Thomas

    2017-07-01

    High rates of false monitoring alarms in intensive care can desensitize staff and therefore pose a significant risk to patient safety. Like other critical arrhythmia alarms, asystole alarms require immediate attention by the care providers as a true asystole event can be acutely life threatening. Here, it is illustrated that most false asystole alarms can be attributed to poor signal quality, and we propose and evaluate an algorithm to identify data windows of poor signal quality and thereby help suppress false asystole alarms. The algorithm combines intuitive signal-quality features (degree of signal saturation and baseline wander) and information from other physiological signals that might be available. Algorithm training and testing was performed on the MIMIC II and 2015 PhysioNet/Computing in Cardiology Challenge databases, respectively. The algorithm achieved an alarm specificity of 81.0% and sensitivity of 95.4%, missing only one out of 22 true asystole alarms. On a separate neonatal data set, the algorithm was able to reject 89.7% (890 out of 992) of false asystole alarms while keeping all 22 true events. The results show that the false asystole alarm rate can be significantly reduced through basic signal quality evaluation.

  1. Segregation of odor identity and intensity during odor discrimination in Drosophila mushroom body.

    Science.gov (United States)

    Xia, Shouzhen; Tully, Tim

    2007-10-02

    Molecular and cellular studies have begun to unravel a neurobiological basis of olfactory processing, which appears conserved among vertebrate and invertebrate species. Studies have shown clearly that experience-dependent coding of odor identity occurs in "associative" olfactory centers (the piriform cortex in mammals and the mushroom body [MB] in insects). What remains unclear, however, is whether associative centers also mediate innate (spontaneous) odor discrimination and how ongoing experience modifies odor discrimination. Here we show in naïve flies that Galphaq-mediated signaling in MB modulates spontaneous discrimination of odor identity but not odor intensity (concentration). In contrast, experience-dependent modification (conditioning) of both odor identity and intensity occurs in MB exclusively via Galphas-mediated signaling. Our data suggest that spontaneous responses to odor identity and odor intensity discrimination are segregated at the MB level, and neural activity from MB further modulates olfactory processing by experience-independent Galphaq-dependent encoding of odor identity and by experience-induced Galphas-dependent encoding of odor intensity and identity.

  2. Investigation of defects in In–Ga–Zn oxide thin film using electron spin resonance signals

    International Nuclear Information System (INIS)

    Nonaka, Yusuke; Kurosawa, Yoichi; Komatsu, Yoshihiro; Ishihara, Noritaka; Oota, Masashi; Nakashima, Motoki; Hirohashi, Takuya; Takahashi, Masahiro; Yamazaki, Shunpei; Obonai, Toshimitsu; Hosaka, Yasuharu; Koezuka, Junichi; Yamauchi, Jun

    2014-01-01

    In–Ga–Zn oxide (IGZO) is a next-generation semiconductor material seen as an alternative to silicon. Despite the importance of the controllability of characteristics and the reliability of devices, defects in IGZO have not been fully understood. We investigated defects in IGZO thin films using electron spin resonance (ESR) spectroscopy. In as-sputtered IGZO thin films, we observed an ESR signal which had a g-value of g = 2.010, and the signal was found to disappear under thermal treatment. Annealing in a reductive atmosphere, such as N 2 atmosphere, generated an ESR signal with g = 1.932 in IGZO thin films. The temperature dependence of the latter signal suggests that the signal is induced by delocalized unpaired electrons (i.e., conduction electrons). In fact, a comparison between the conductivity and ESR signal intensity revealed that the signal's intensity is related to the number of conduction electrons in the IGZO thin film. The signal's intensity did not increase with oxygen vacancy alone but also with increases in both oxygen vacancy and hydrogen concentration. In addition, first-principle calculation suggests that the conduction electrons in IGZO may be generated by defects that occur when hydrogen atoms are inserted into oxygen vacancies

  3. Investigation of defects in In–Ga–Zn oxide thin film using electron spin resonance signals

    Energy Technology Data Exchange (ETDEWEB)

    Nonaka, Yusuke; Kurosawa, Yoichi; Komatsu, Yoshihiro; Ishihara, Noritaka; Oota, Masashi; Nakashima, Motoki; Hirohashi, Takuya; Takahashi, Masahiro; Yamazaki, Shunpei [Semiconductor Energy Laboratory Co., Ltd., 398 Hase, Atsugi, Kanagawa 243-0036 (Japan); Obonai, Toshimitsu; Hosaka, Yasuharu; Koezuka, Junichi [Advanced Film Device, Inc., 161-2 Masuzuka, Tsuga-machi, Tochigi, Tochigi 328-0114 (Japan); Yamauchi, Jun [Semiconductor Energy Laboratory Co., Ltd., 398 Hase, Atsugi, Kanagawa 243-0036 (Japan); Emeritus Professor of Kyoto University, Oiwake-cho, Kitashirakawa, Kyoto 606-8502 (Japan)

    2014-04-28

    In–Ga–Zn oxide (IGZO) is a next-generation semiconductor material seen as an alternative to silicon. Despite the importance of the controllability of characteristics and the reliability of devices, defects in IGZO have not been fully understood. We investigated defects in IGZO thin films using electron spin resonance (ESR) spectroscopy. In as-sputtered IGZO thin films, we observed an ESR signal which had a g-value of g = 2.010, and the signal was found to disappear under thermal treatment. Annealing in a reductive atmosphere, such as N{sub 2} atmosphere, generated an ESR signal with g = 1.932 in IGZO thin films. The temperature dependence of the latter signal suggests that the signal is induced by delocalized unpaired electrons (i.e., conduction electrons). In fact, a comparison between the conductivity and ESR signal intensity revealed that the signal's intensity is related to the number of conduction electrons in the IGZO thin film. The signal's intensity did not increase with oxygen vacancy alone but also with increases in both oxygen vacancy and hydrogen concentration. In addition, first-principle calculation suggests that the conduction electrons in IGZO may be generated by defects that occur when hydrogen atoms are inserted into oxygen vacancies.

  4. Higher-Order Cyclostationarity Detection for Spectrum Sensing

    Directory of Open Access Journals (Sweden)

    Julien Renard

    2010-01-01

    Full Text Available Recent years have shown a growing interest in the concept of Cognitive Radios (CRs, able to access portions of the electromagnetic spectrum in an opportunistic operating way. Such systems require efficient detectors able to work in low Signal-to-Noise Ratio (SNR environments, with little or no information about the signals they are trying to detect. Energy detectors are widely used to perform such blind detection tasks, but quickly reach the so-called SNR wall below which detection becomes impossible Tandra (2005. Cyclostationarity detectors are an interesting alternative to energy detectors, as they exploit hidden periodicities present in man-made signals, but absent in noise. Such detectors use quadratic transformations of the signals to extract the hidden sine-waves. While most of the literature focuses on the second-order transformations of the signals, we investigate the potential of higher-order transformations of the signals. Using the theory of Higher-Order Cyclostationarity (HOCS, we derive a fourth-order detector that performs similarly to the second-order ones to detect linearly modulated signals, at SNR around 0 dB, which may be used if the signals of interest do not exhibit second-order cyclostationarity. More generally this paper reviews the relevant aspects of the cyclostationary and HOCS theory, and shows their potential for spectrum sensing.

  5. Early lactate clearance in septic patients with elevated lactate levels admitted from the emergency department to intensive care: time to aim higher?

    Science.gov (United States)

    Walker, Craig A; Griffith, David M; Gray, Alasdair J; Datta, Deepankar; Hay, Alasdair W

    2013-10-01

    Septic patients with hyperlactatemia have increased mortality rates, irrespective of hemodynamic and oxygen-derived variables. The aims of the study are the following: (1) to ascertain whether lactate clearance (LC) (percentage change in lactate over unit time) predicts mortality in septic patients admitted to intensive care directly from the emergency department and (2) to calculate the optimal "cut-off" value for mortality prediction. Three-year retrospective observational study of consecutive patients with severe sepsis and septic shock admitted to intensive care from the emergency department of a tertiary UK hospital. We calculated 6-hour LC, performed receiver operating characteristic analyses to calculate optimal cut-off values for initial lactate and LC, dichotomized patients according to the LC cut-off, and calculated hazard ratios using a Cox proportional hazards model. One hundred six patients were identified; 78, after exclusions. Lactate clearance was independently associated with 30-day mortality (P<.04); optimal cut-off, 36%. Mortality rates were 61.1% and 10.7% for patients with 6-hour LC 36% or less and greater than 36%, respectively. Hazard ratio for death with LC 36% or less was 7.33 (95% confidence interval, 2.17-24.73; P<.001). Six-hour LC was independently associated with mortality, and the optimal cut-off value was 36%, significantly higher than previously reported. We would support further research investigating this higher LC as a distinct resuscitation end point in patients with severe sepsis and septic shock. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Phase and synchronous detector theory as applied to beam position and intensity measurements

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.

    1995-01-01

    A popular signal processing technique for beam position measurements uses the principle of amplitude-to-phase (AM/PM) conversion and phase detection. This technique processes position-sensitive beam-image-current probe-signals into output signals that are proportional to the beam's position. These same probe signals may be summed and processed in a different fashion to provide output signals that are proportional to the peak beam current which is typically referred to as beam intensity. This paper derives the transfer functions for the AM/PM beam position and peak beam current processors

  7. Stability of X-band EPR signals from fingernails under vacuum storage.

    Science.gov (United States)

    Sholom, Sergey; McKeever, Stephen

    2017-12-01

    EPR signals of different origin have been tested in human finger- and toe-nails with an X-band EPR technique for different conditions of nail storage. Three different signals were identified, namely a singlet at g=2.005, a doublet at g=2.004 with a splitting constant A=1.8 mT, and an anisotropic signal at g1=2.057, g2=2.029 and g3=2.003 (positions of local extrema). All EPR spectra from nails, whether irradiated or mechanically stressed, can be described as a superposition of these three signals. The singlet is responsible for the background signal (BG), is the main component of radiation-induced signals (RIS) for low doses (100 Gy or lower) and also contributes to mechanically-induced signals (MIS). This signal is quite stable under vacuum storage, but can be reduced almost to zero by soaking in water. The behavior of this signal under ambient conditions depends on many factors, such as absorbed dose, air humidity, and ambient illumination intensity at the place of storage. The doublet arises after exposure of nails to high (few hundreds Gy and higher) doses or after mechanical stress of samples. Depending on how this signal was obtained, it may have bulk or surface locations with quite different stability properties. The surface-located doublet (generated on the nail edges during cutting or clipping) is quite unstable and decays over about two hours for samples stored at ambient conditions and within several seconds for samples immersed in water. The volume-distributed doublet decays within a few minutes in water, several hours at ambient conditions and several days in vacuum. The anisotropic signal may also be generated by both ionizing radiation and mechanical stress; this signal is quite stable in vacuum and decays over several days at ambient conditions or a few tens of minutes in water. The reference lines for the above-described three EPR signals were obtained and a procedure of spectra deconvolution was developed and tested on samples exposed to both

  8. A beam intensity monitor for the evaluation beamline for soft x-ray optical elements

    International Nuclear Information System (INIS)

    Imazono, Takashi; Moriya, Naoji; Harada, Yoshihisa; Sano, Kazuo; Koike, Masato

    2012-01-01

    Evaluation Beamline for Soft X-Ray Optical Elements (BL-11) at the SR Center of Ritsumeikan University has been operated to measure the wavelength and angular characteristics of soft x-ray optical components in a wavelength range of 0.65-25 nm using a reflecto-diffractometer (RD). The beam intensity monitor that has been equipped in BL-11 has observed the signal of the zero-th order light. For the purpose of more accurate evaluation of the performance of optical components, a new beam intensity monitor to measure the intensity of the first order light from the monochromator in BL-11 has been developed and installed in just front of RD. The strong positive correlation between the signal of the beam monitor and a detector equipped in the RD is shown. It is successful that the beam intensity of the first order light can be monitored in real time.

  9. Is courtship intensity a signal of male parental care in Red-winged Blackbirds (Agelaius phoeniceus)?

    Science.gov (United States)

    Yasukawa, Ken; Knight, Richard L.; Skagen, Susan Knight

    1987-01-01

    We studied Red-winged Blackbird (Agelaius phoeniceus) behavior in marsh and prairie habitats to determine whether courting males provide cues of their nest defense, whether females prefer males that defend nests vigorously, and whether male nest defense affects nest success. We found no evidence that courtship behavior provides cues of male nest defense, or that females prefer males that court intensely. We found evidence that females nesting in marshes prefer males that defend nests intensely, but no evidence that intensely defending males in the prairie habitat achieve high nest success. We found differences, however, between marsh and prairie habitats that suggest a coarse-grained relationship between male parental quality and female choice of mate in this species.

  10. Variability in echolocation call intensity in a community of horseshoe bats: a role for resource partitioning or communication?

    Science.gov (United States)

    Schuchmann, Maike; Siemers, Björn M

    2010-09-17

    Only recently data on bat echolocation call intensities is starting to accumulate. Yet, intensity is an ecologically crucial parameter, as it determines the extent of the bats' perceptual space and, specifically, prey detection distance. Interspecifically, we thus asked whether sympatric, congeneric bat species differ in call intensities and whether differences play a role for niche differentiation. Specifically, we investigated whether R. mehelyi that calls at a frequency clearly above what is predicted by allometry, compensates for frequency-dependent loss in detection distance by using elevated call intensity. Maximum echolocation call intensities might depend on body size or condition and thus be used as an honest signal of quality for intraspecific communication. We for the first time investigated whether a size-intensity relation is present in echolocating bats. We measured maximum call intensities and frequencies for all five European horseshoe bat species. Maximum intensity differed among species largely due to R. euryale. Furthermore, we found no compensation for frequency-dependent loss in detection distance in R. mehelyi. Intraspecifically, there is a negative correlation between forearm lengths and intensity in R. euryale and a trend for a negative correlation between body condition index and intensity in R. ferrumequinum. In R. hipposideros, females had 8 dB higher intensities than males. There were no correlations with body size or sex differences and intensity for the other species. Based on call intensity and frequency measurements, we estimated echolocation ranges for our study community. These suggest that intensity differences result in different prey detection distances and thus likely play some role for resource access. It is interesting and at first glance counter-intuitive that, where a correlation was found, smaller bats called louder than large individuals. Such negative relationship between size or condition and vocal amplitude may

  11. Degree of polarization and source counts of faint radio sources from Stacking Polarized intensity

    International Nuclear Information System (INIS)

    Stil, J. M.; George, S. J.; Keller, B. W.; Taylor, A. R.

    2014-01-01

    We present stacking polarized intensity as a means to study the polarization of sources that are too faint to be detected individually in surveys of polarized radio sources. Stacking offers not only high sensitivity to the median signal of a class of radio sources, but also avoids a detection threshold in polarized intensity, and therefore an arbitrary exclusion of sources with a low percentage of polarization. Correction for polarization bias is done through a Monte Carlo analysis and tested on a simulated survey. We show that the nonlinear relation between the real polarized signal and the detected signal requires knowledge of the shape of the distribution of fractional polarization, which we constrain using the ratio of the upper quartile to the lower quartile of the distribution of stacked polarized intensities. Stacking polarized intensity for NRAO VLA Sky Survey (NVSS) sources down to the detection limit in Stokes I, we find a gradual increase in median fractional polarization that is consistent with a trend that was noticed before for bright NVSS sources, but is much more gradual than found by previous deep surveys of radio polarization. Consequently, the polarized radio source counts derived from our stacking experiment predict fewer polarized radio sources for future surveys with the Square Kilometre Array and its pathfinders.

  12. Comments on the stochastic characteristics of fission chamber signals

    International Nuclear Information System (INIS)

    Pál, L.; Pázsit, I.; Elter, Zs.

    2014-01-01

    This paper reports on theoretical investigations of the stochastic properties of the signal series of ionisation chambers, in particular fission chambers. First, a simple and transparent derivation is given of the higher order moments of the random detector signal for incoming pulses with a non-homogeneous Poisson distribution and random pulse heights and arbitrary shape. Exact relationships are derived for the higher order moments of the detector signal, which constitute a generalisation of the so-called higher order Campbelling techniques. The probability distribution of the number of time points when the signal exceeds a certain level is also derived. Then, a few simple pulse shapes and amplitude distributions are selected as idealised models of the detector signals. Assuming that the incoming particles form a homogeneous Poisson process, explicit expressions are given for the higher order moments of the signal and the number of level crossings in a given time interval for the selected pulse shapes

  13. Unmyelinated tactile cutaneous nerves signal erotic sensations.

    Science.gov (United States)

    Jönsson, Emma H; Backlund Wasling, Helena; Wagnbeck, Vicktoria; Dimitriadis, Menelaos; Georgiadis, Janniko R; Olausson, Håkan; Croy, Ilona

    2015-06-01

    Intrapersonal touch is a powerful tool for communicating emotions and can among many things evoke feelings of eroticism and sexual arousal. The peripheral neural mechanisms of erotic touch signaling have been less studied. C tactile afferents (unmyelinated low-threshold mechanoreceptors), known to underpin pleasant aspects of touch processing, have been posited to play an important role. In two studies, we investigated the relationship between C tactile activation and the perception of erotic and pleasant touch, using tactile brushing stimulation. In total, 66 healthy subjects (37 women, age range 19-51 years) were examined. In study 1 (n = 20), five different stroking velocities were applied to the forearm and the inner thigh. The participants answered questions about partnership, mood, and touch. In study 2 (n = 46), the same five stroking velocities were applied to the forearm. The participants answered questions about partnership, touch, and sexuality. Both touch eroticism and pleasantness were rated significantly higher for C tactile optimal velocities compared with suboptimal velocities. No difference was found between the ratings of the thigh and the forearm. The velocity-dependent rating curves of pleasantness, intensity, and eroticism differed from each other. Pleasantness was best explained by a quadratic fit, intensity by a linear fit, and eroticism by both. A linear transformation of pleasantness and intensity predicted the observed eroticism ratings reliably. Eroticism ratings were negatively correlated with length of relationship. Touch was rated most erotic when perceived as pleasant and weak. In human hairy skin, perception of pleasantness is correlated with the firing rate of C tactile afferents, and perception of intensity is correlated with the firing rate of Aβ afferents. Accordingly, eroticism may be perceived most readily for touch stimuli that induce high activity in C tactile fibers and low activity in Aβ fibers. © 2015 International

  14. Improving comparability between microarray probe signals by thermodynamic intensity correction

    DEFF Research Database (Denmark)

    Bruun, G. M.; Wernersson, Rasmus; Juncker, Agnieszka

    2007-01-01

    different probes. It is therefore of great interest to correct for the variation between probes. Much of this variation is sequence dependent. We demonstrate that a thermodynamic model for hybridization of either DNA or RNA to a DNA microarray, which takes the sequence-dependent probe affinities...... determination of transcription start sites for a subset of yeast genes. In another application, we identify present/absent calls for probes hybridized to the sequenced Escherichia coli strain O157:H7 EDL933. The model improves the correct calls from 85 to 95% relative to raw intensity measures. The model thus...... makes applications which depend on comparisons between probes aimed at different sections of the same target more reliable....

  15. Ras signaling in aging and metabolic regulation.

    Science.gov (United States)

    Slack, Cathy

    2017-12-07

    Aberrant signal transduction downstream of the Ras GTPase has a well-established role in tumorigenesis. Mutations that result in hyperactivation of Ras are responsible for a third of all human cancers. Hence, small molecule inhibitors of the Ras signal transduction cascade have been under intense focus as potential cancer treatments. In both invertebrate and mammalian models, emerging evidence has also implicated components of the Ras signaling pathway in aging and metabolic regulation. Here, I review the current evidence for Ras signaling in these newly discovered roles highlighting the interactions between the Ras pathway and other longevity assurance mechanisms. Defining the role of Ras signaling in maintaining age-related health may have important implications for the development of interventions that could not only increase lifespan but also delay the onset and/or progression of age-related functional decline.

  16. High intensity focused ultrasound treatment of adenomyosis: The relationship between the features of magnetic resonance imaging on T2 weighted images and the therapeutic efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Chunmei [State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Ultrasound in Medicine and Engineering, Chongqing Haifu Hospital, College of Biomedical Engineering, Chongqing Medical University, Chongqing (China); Setzen, Raymond [Department of Obstetrics and Gynecology, Chris Hani Baragwanath Academic Hospital, Johannesburg (South Africa); Liu, Zhongqiong; Liu, Yunchang [State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Ultrasound in Medicine and Engineering, Chongqing Haifu Hospital, College of Biomedical Engineering, Chongqing Medical University, Chongqing (China); Xie, Bin [Department of Ultrasound, Huanggang Central Hospital, Huanggang City, Hubei 438000 (China); Aili, Aixingzi, E-mail: 1819483078@qq.com [Shanghai First Maternity and Infant Health Hospital, Shanghai (China); Zhang, Lian, E-mail: lianwzhang@yahoo.com [State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Ultrasound in Medicine and Engineering, Chongqing Haifu Hospital, College of Biomedical Engineering, Chongqing Medical University, Chongqing (China)

    2017-04-15

    Objectives: To investigate the relationship between the features of magnetic resonance imaging (MRI) on T2 weighted images (T2WI) and the therapeutic efficacy of high intensity focused ultrasound (HIFU) on adenomyosis. Materials and methods: From January 2011 to November 2015, four hundred and twenty-eight patients with symptomatic adenomyosis were treated with HIFU. Based on the signal intensity and the number of hyperintense foci in the adenomyotic lesions on T2WI, the patients were classified into groups. The day after HIFU ablation patients underwent contrast-enhanced MRI and a comparison was made of non-perfused volume (NPV) ratio, energy efficiency factor (EEF), treatment time, sonication time, and adverse effects. Results: No significant difference in terms of HIFU treatment settings and results was observed between the group of patients with hypointense adenomyotic lesions and the group with isointense adenomyotic lesions (P > 0.05). However, the sonication time and EEF were significantly higher in the group with multiple hyperintense foci compared to the group with few hyperintense foci. The NPV ratio achieved in the lesions with multiple hyperintenese foci was significantly lower than that in the lesions with few hyperintense foci (P < 0.05). No significant difference was observed in the rate of adverse effects between the two groups. Conclusions: Based on our results, the response of the adenomyotic lesions to HIFU treatment is not related to the signal intensity of adenomyotic lesions on T2WI. However, the number of the high signal intensity foci in the adenomyotic lesions on T2WI can be considered as a predictive factor to help select patients for HIFU treatment.

  17. High intensity focused ultrasound treatment of adenomyosis: The relationship between the features of magnetic resonance imaging on T2 weighted images and the therapeutic efficacy

    International Nuclear Information System (INIS)

    Gong, Chunmei; Setzen, Raymond; Liu, Zhongqiong; Liu, Yunchang; Xie, Bin; Aili, Aixingzi; Zhang, Lian

    2017-01-01

    Objectives: To investigate the relationship between the features of magnetic resonance imaging (MRI) on T2 weighted images (T2WI) and the therapeutic efficacy of high intensity focused ultrasound (HIFU) on adenomyosis. Materials and methods: From January 2011 to November 2015, four hundred and twenty-eight patients with symptomatic adenomyosis were treated with HIFU. Based on the signal intensity and the number of hyperintense foci in the adenomyotic lesions on T2WI, the patients were classified into groups. The day after HIFU ablation patients underwent contrast-enhanced MRI and a comparison was made of non-perfused volume (NPV) ratio, energy efficiency factor (EEF), treatment time, sonication time, and adverse effects. Results: No significant difference in terms of HIFU treatment settings and results was observed between the group of patients with hypointense adenomyotic lesions and the group with isointense adenomyotic lesions (P > 0.05). However, the sonication time and EEF were significantly higher in the group with multiple hyperintense foci compared to the group with few hyperintense foci. The NPV ratio achieved in the lesions with multiple hyperintenese foci was significantly lower than that in the lesions with few hyperintense foci (P < 0.05). No significant difference was observed in the rate of adverse effects between the two groups. Conclusions: Based on our results, the response of the adenomyotic lesions to HIFU treatment is not related to the signal intensity of adenomyotic lesions on T2WI. However, the number of the high signal intensity foci in the adenomyotic lesions on T2WI can be considered as a predictive factor to help select patients for HIFU treatment.

  18. Spaceborne intensity interferometry via spacecraft formation flight

    Science.gov (United States)

    Ribak, Erez N.; Gurfil, Pini; Moreno, Coral

    2012-07-01

    Interferometry in space has marked advantages: long integration times and observation in spectral bands where the atmosphere is opaque. When installed on separate spacecraft, it also has extended and flexible baselines for better filling of the uv plane. Intensity interferometry has an additional advantage, being insensitive to telescope and path errors, but is unfortunately much less light-sensitive. In planning towards such a mission, we are experimenting with some fundamental research issues. Towards this end, we constructed a system of three vehicles floating on an air table in formation flight, with an autonomous orbit control. Each such device holds its own light collector, detector, and transmitter, to broadcast its intensity signal towards a central receiving station. At this station we implement parallel radio receivers, analogue to digital converters, and a digital three-way correlator. Current technology limits us to ~1GHz transmission frequency, which corresponds to a comfortable 0.3m accuracy in light-bucket shape and in its relative position. Naïve calculations place our limiting magnitude at ~7 in the blue and ultraviolet, where amplitude interferometers are limited. The correlation signal rides on top of this huge signal with its own Poisson noise, requiring a very large dynamic range, which needs to be transmitted in full. We are looking at open questions such as deployable optical collectors and radio antennae of similar size of a few meters, and how they might influence our data transmission and thus set our flux limit.

  19. Improved BER based on intensity noise alleviation using developed detection technique for incoherent SAC-OCDMA systems

    Science.gov (United States)

    Al-Khafaji, Hamza M. R.; Aljunid, S. A.; Fadhil, Hilal A.

    2012-06-01

    The major drawback of incoherent spectral-amplitude coding optical code-division multiple-access (SAC-OCDMA) systems is their inherent intensity noise originating due to the incoherency of the broadband light sources. In this paper, we propose a developed detection technique named the modified-AND subtraction detection for incoherent SAC-OCDMA systems. This detection technique is based upon decreasing the received signal strength during the decoding process by dividing the spectrum of the utilized code sequence. The proposed technique is capable of mitigating the intensity noise effect, as well as suppressing the multiple-access interference impact. Based on modified quadratic congruence (MQC) code, the analytical results reveal that the modified-AND detection offer best bit-error rate (BER) performance and enables MQC code to support higher transmission rate up to 1.25 Gb/s compared to conventional AND detection. Furthermore, we ascertained that the proposed technique enhances the system performance using a simulation experiment.

  20. Nature sunlight bleaching of Ti center ESR signal in quartz

    International Nuclear Information System (INIS)

    Yin Gongming; Liu Chunru; Li Jianping; Fang Jiahu; Gao Lu; Lin Min

    2009-01-01

    Quartz grains were extracted from granite. Bleaching was carried out in four different area chosen for their different altitudes (Beijing, Yinchuan, Germu, Lhasa), in order to observe their behavior under different intensities of the UV (Ultra violet) component of sunlight. The result of our experiments indicate that the Ti center signal is totally bleachable by the natural sunlight and show that the Ti center signal was reduced to zero after about 128 h in Beijing and after 56 h for Lhasa. We can speculate that different intensity of the UV component of sunlight lead to different minimal time necessary to obtain the total bleaching of the quartz sample. (authors)

  1. High-intensity lower limb endurance training in chronic respiratory disease

    OpenAIRE

    Tanaka, Takako; Arizono, Shinichi; Hanada, Masatoshi; Senjyu, Hideaki

    2015-01-01

    High-intensity endurance training is mainly undertaken during pulmonary rehabilitation for patients with chronic respiratory disease. High-intensity endurance training is recommended in many clinical management guidelines. High-intensity endurance training involves training generally at an intensity of at 60-80% of the patient’s peak work capacity or higher. The effects of high-intensity lower limb endurance training have mostly been investigated in chronic obstructive pulmonary disease (COPD...

  2. 1 Tbit/inch2 Recording in Angular-Multiplexing Holographic Memory with Constant Signal-to-Scatter Ratio Schedule

    Science.gov (United States)

    Hosaka, Makoto; Ishii, Toshiki; Tanaka, Asato; Koga, Shogo; Hoshizawa, Taku

    2013-09-01

    We developed an iterative method for optimizing the exposure schedule to obtain a constant signal-to-scatter ratio (SSR) to accommodate various recording conditions and achieve high-density recording. 192 binary images were recorded in the same location of a medium in approximately 300×300 µm2 using an experimental system embedded with a blue laser diode with a 405 nm wavelength and an objective lens with a 0.85 numerical aperture. The recording density of this multiplexing corresponds to 1 Tbit/in.2. The recording exposure time was optimized through the iteration of a three-step sequence consisting of total reproduced intensity measurement, target signal calculation, and recording energy density calculation. The SSR of pages recorded with this method was almost constant throughout the entire range of the reference beam angle. The signal-to-noise ratio of the sampled pages was over 2.9 dB, which is higher than the reproducible limit of 1.5 dB in our experimental system.

  3. Segregation of odor identity and intensity during odor discrimination in Drosophila mushroom body.

    Directory of Open Access Journals (Sweden)

    Shouzhen Xia

    2007-10-01

    Full Text Available Molecular and cellular studies have begun to unravel a neurobiological basis of olfactory processing, which appears conserved among vertebrate and invertebrate species. Studies have shown clearly that experience-dependent coding of odor identity occurs in "associative" olfactory centers (the piriform cortex in mammals and the mushroom body [MB] in insects. What remains unclear, however, is whether associative centers also mediate innate (spontaneous odor discrimination and how ongoing experience modifies odor discrimination. Here we show in naïve flies that Galphaq-mediated signaling in MB modulates spontaneous discrimination of odor identity but not odor intensity (concentration. In contrast, experience-dependent modification (conditioning of both odor identity and intensity occurs in MB exclusively via Galphas-mediated signaling. Our data suggest that spontaneous responses to odor identity and odor intensity discrimination are segregated at the MB level, and neural activity from MB further modulates olfactory processing by experience-independent Galphaq-dependent encoding of odor identity and by experience-induced Galphas-dependent encoding of odor intensity and identity.

  4. Reveal or Conceal? Signaling Strategies for Building Legitimacy in Cleantech Firms

    DEFF Research Database (Denmark)

    Bjørnåli, Ekaterina; Giones, Ferran; Billström, Anders

    2017-01-01

    cases while investigating their actions in different phases of the venture’s evolution. The results suggest that, contrary to signaling theory expectations, young clean-tech firms do not always build legitimacy by conveying information on their strengths. Instead, we observe that they use signaling......New entrants in technology-intense industries are in a race to build legitimacy in order to compete with established players. Legitimacy has been identified as a driver of venture survival and growth; it helps mitigate third-party uncertainty and so facilitates access to resources, engagement...... with customers and other stakeholders. Nevertheless, we know little about how legitimacy is built and how new entrants build legitimacy in complex technology-intensive industries. In this research we explore how Norwegian cleantech firms use signaling and strategic actions to build legitimacy. We analyze five...

  5. An analytical method to simulate the H I 21-cm visibility signal for intensity mapping experiments

    Science.gov (United States)

    Sarkar, Anjan Kumar; Bharadwaj, Somnath; Marthi, Visweshwar Ram

    2018-01-01

    Simulations play a vital role in testing and validating H I 21-cm power spectrum estimation techniques. Conventional methods use techniques like N-body simulations to simulate the sky signal which is then passed through a model of the instrument. This makes it necessary to simulate the H I distribution in a large cosmological volume, and incorporate both the light-cone effect and the telescope's chromatic response. The computational requirements may be particularly large if one wishes to simulate many realizations of the signal. In this paper, we present an analytical method to simulate the H I visibility signal. This is particularly efficient if one wishes to simulate a large number of realizations of the signal. Our method is based on theoretical predictions of the visibility correlation which incorporate both the light-cone effect and the telescope's chromatic response. We have demonstrated this method by applying it to simulate the H I visibility signal for the upcoming Ooty Wide Field Array Phase I.

  6. Data-Intensive Evaluation: The Concept, Methods, and Prospects of Higher Education Monitoring Evaluation

    Science.gov (United States)

    Wang, Zhanjun; Qiao, Weifeng; Li, Jiangbo

    2016-01-01

    Higher education monitoring evaluation is a process that uses modern information technology to continually collect and deeply analyze relevant data, visually present the state of higher education, and provide an objective basis for value judgments and scientific decision making by diverse bodies Higher education monitoring evaluation is…

  7. Experimental separation of a frequency spin echo signal

    International Nuclear Information System (INIS)

    Bun'kov, Yu.M.; Dmitriev, V.V.

    1981-01-01

    To study systems with bound nuclear-electron precession CsMnF 2 antiferromagnetic light-plane monocrystal was investigated. Crystal orientation was carried out by roentgenoscopy. Measurements were performed at helium temperatures in the 500-700 MHz frequency range. A NMR pulsed spectrometer with generators of both resonance and doubled frequency was used to produce an echo signal (to study by the parametric echo method). It was shown that the theory of the formation of a frequency modulated echo (FM echo) did not fully describe the properties of the echo signals in systems with dynamic frequency shift (DFS). An intense spin echo signal, which formation was apparently connected with other nonlinear properties of the systems with nuclear-electron precession, was observed. The spin echo signal in magnetics with DFS, which properties correspond to notions of the frequency mechanism of echo formation, was experimentally separated. As a result of the investigations it had been possible to settle contradictions between the theory of FM echo formation and the experimental results for the last 9 years. It turned out that the mechanism of FM echo formation in the magnetics with bound nuclear-electron precession was effective only at large delay times between the pulses. In the range of small delays the FM echo is ''jammed'' by a gigantic echo signal of a nature different from that of the traditional FM signal. The constant of gigantic echo intensity drop at increasing delay between the pulses weakly depends on spin-spin relaxation time [ru

  8. Muscle fatigue and contraction intensity modulates the complexity of surface electromyography.

    Science.gov (United States)

    Cashaback, Joshua G A; Cluff, Tyler; Potvin, Jim R

    2013-02-01

    Nonlinear dynamical techniques offer a powerful approach for the investigation of physiological time series. Multiscale entropy analyses have shown that pathological and aging systems are less complex than healthy systems and this finding has been attributed to degraded physiological control processes. A similar phenomenon may arise during fatiguing muscle contractions where surface electromyography signals undergo temporal and spectral changes that arise from the impaired regulation of muscle force production. Here we examine the affect of fatigue and contraction intensity on the short and long-term complexity of biceps brachii surface electromyography. To investigate, we used an isometric muscle fatigue protocol (parsed into three windows) and three contraction intensities (% of maximal elbow joint moment: 40%, 70% and 100%). We found that fatigue reduced the short-term complexity of biceps brachii activity during the last third of the fatiguing contraction. We also found that the complexity of surface electromyography is dependent on contraction intensity. Our results show that multiscale entropy is sensitive to muscle fatigue and contraction intensity and we argue it is imperative that both factors be considered when evaluating the complexity of surface electromyography signals. Our data contribute to a converging body of evidence showing that multiscale entropy can quantify subtle information content in physiological time series. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Progress toward a microsecond duration, repetitive, intense-ion beam for active spectroscopic measurements on ITER

    International Nuclear Information System (INIS)

    Davis, H.A.; Bartsch, R.R.; Barnes, C.W.

    1996-01-01

    The authors describe the design of an intense, pulsed, repetitive, neutral beam based on magnetically insulated diode technology for injection into ITER for spectroscopic measurements of thermalizing alpha particle and thermal helium density profiles, ion temperature, plasma rotation, and low Z impurity concentrations in the confinement region. The beam is being developed to enhance low signal-to-noise ratios expected with conventional steady-state ion beams because of severe beam attenuation and intense bremstrahlung emission. A 5 GW (e.g., 100 keV, 50 kA) one-microsecond-duration beam would increase the signal by 10 3 compared to a conventional 5 MW beam with signal-to-noise ratios comparable to those from a chopped conventional beam in one second

  10. [Oligonucleotide derivatives in the nucleic acid hybridization analysis. II. Isothermal signal amplification in process of DNA analysis by minisequencing].

    Science.gov (United States)

    Dmitrienko, E V; Khomiakova, E A; Pyshnaia; Bragin, A G; Vedernikov, V E; Pyshnyĭ, D V

    2010-01-01

    The isothermal amplification of reporter signal via limited probe extension (minisequencing) upon hybridization of nucleic acids has been studied. The intensity of reporter signal has been shown to increase due to enzymatic labeling of multiple probes upon consecutive hybridization with one DNA template both in homophase and heterophase assays using various kinds of detection signal: radioisotope label, fluorescent label, and enzyme-linked assay. The kinetic scheme of the process has been proposed and kinetic parameters for each step have been determined. The signal intensity has been shown to correlate with physicochemical characteristics of both complexes: probe/DNA and product/DNA. The maximum intensity has been observed at minimal difference between the thermodynamic stability of these complexes, provided the reaction temperature has been adjusted near their melting temperature values; rising or lowering the reaction temperature reduces the amount of reporting product. The signal intensity has been shown to decrease significantly upon hybridization with the DNA template containing single-nucleotide mismatches. Limited probe extension assay is useful not only for detection of DNA template but also for its quantitative characterization.

  11. Increased signal intensity at the proximal patellar tendon: correlation between MR imaging and histology in eight cadavers and clinical MR imaging studies

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Seong Jong; Jin, Wook; Yoon, So Hee; Park, So Young [Kyung Hee University Hospital at Gangdong, Kyung Hee University School of Medicine, Department of Radiology, Seoul (Korea, Republic of); Park, Yong-Koo [Kyung Hee University Medical Center, Department of Pathology, Seoul (Korea, Republic of); Kim, Gou Young [Kyung Hee University Hospital at Gangdong, Kyung Hee University School of Medicine, Department of Pathology, Seoul (Korea, Republic of); Lee, Jung Eun; Park, Ji Seon; Ryu, Kyung Nam [Kyung Hee University Medical Center, Department of Radiology, Seoul (Korea, Republic of)

    2015-10-15

    We set out to investigate the cause of persistently increased signal intensity (SI) in the posterior portion of the proximal patellar tendon (pPT) on T1-weighted images (T1WI). MR imaging was performed in eight cadavers, followed by gross histological examination. In addition, 84 patients without trauma history or anterior knee pain were included to compare the SI of the PTs. The patients were divided according to their age, sex, and Kellgren-Lawrence (KL) grades. The length and thickness of the increased SI portion in the pPT and whole PT (wPT) on T1WI were recorded. Histological specimens demonstrated that the adipose tissue, vessels, and perivascular connective tissue invaginated into the posterior portion of the pPT. This histological anatomy corresponded to the pPT signal change on MR imaging. There was linear and interdigitating increased SI of the pPT in all of the 84 patients (100 %). There were no differences in the lengths and thicknesses of the increased SI portion of pPTs and wPTs according to age, sex, and KL grade (all p > 0.05). The increased SI of the pPT on T1WI and fluid-sensitive MR images results from invaginating fat, vessels, and perivascular connective tissue. It is not pathological, but a normal and common finding. (orig.)

  12. Deep Learning in Visual Computing and Signal Processing

    OpenAIRE

    Xie, Danfeng; Zhang, Lei; Bai, Li

    2017-01-01

    Deep learning is a subfield of machine learning, which aims to learn a hierarchy of features from input data. Nowadays, researchers have intensively investigated deep learning algorithms for solving challenging problems in many areas such as image classification, speech recognition, signal processing, and natural language processing. In this study, we not only review typical deep learning algorithms in computer vision and signal processing but also provide detailed information on how to apply...

  13. Pseudo-stokes vector from complex signal representation of a speckle pattern and its applications to micro-displacement measurement

    DEFF Research Database (Denmark)

    Wang, W.; Ishijima, R.; Matsuda, A.

    2010-01-01

    As an improvement of the intensity correlation used widely in conventional electronic speckle photography, we propose a new technique for displacement measurement based on correlating Stokes-like parameters derivatives for transformed speckle patterns. The method is based on a Riesz transform of ...... are presented that demonstrate the validity and advantage of the proposed pseudo-Stokes vector correlation technique over conventional intensity correlation technique....... of the intensity speckle pattern, which converts the original real-valued signal into a complex signal. In closest analogy to the polarisation of a vector wave, the Stokes-like vector constructed from the spatial derivative of the generated complex signal has been applied for correlation. Experimental results...

  14. French intensive truck garden

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, T D

    1983-01-01

    The French Intensive approach to truck gardening has the potential to provide substantially higher yields and lower per acre costs than do conventional farming techniques. It was the intent of this grant to show that there is the potential to accomplish the gains that the French Intensive method has to offer. It is obvious that locally grown food can greatly reduce transportation energy costs but when there is the consideration of higher efficiencies there will also be energy cost reductions due to lower fertilizer and pesticide useage. As with any farming technique, there is a substantial time interval for complete soil recovery after there have been made substantial soil modifications. There were major crop improvements even though there was such a short time since the soil had been greatly disturbed. It was also the intent of this grant to accomplish two other major objectives: first, the garden was managed under organic techniques which meant that there were no chemical fertilizers or synthetic pesticides to be used. Second, the garden was constructed so that a handicapped person in a wheelchair could manage and have a higher degree of self sufficiency with the garden. As an overall result, I would say that the garden has taken the first step of success and each year should become better.

  15. Intensity of interprofessional collaboration among intensive care nurses at a tertiary hospital.

    Science.gov (United States)

    Serrano-Gemes, G; Rich-Ruiz, M

    To measure the intensity of interprofessional collaboration (IPC) in nurses of an intensive care unit (ICU) at a tertiary hospital, to check differences between the dimensions of the Intensity of Interprofessional Collaboration Questionnaire, and to identify the influence of personal variables. A cross-sectional descriptive study was conducted with 63 intensive care nurses selected by simple random sampling. Explanatory variables: age, sex, years of experience in nursing, years of experience in critical care, workday type and work shift type; variable of outcome: IPC. The IPC was measured by: Intensity of Interprofessional Collaboration Questionnaire. Descriptive and bivariate statistical analysis (IPC and its dimensions with explanatory variables). 73.8% were women, with a mean age of 46.54 (±6.076) years. The average years experience in nursing and critical care was 23.03 (±6.24) and 14.25 (±8.532), respectively. 77% had a full time and 95.1% had a rotating shift. 62.3% obtained average IPC values. Statistically significant differences were found (P<.05) between IPC (overall score) and overall assessment with years of experience in critical care. This study shows average levels of IPC; the nurses with less experience in critical care obtained higher IPC and overall assessment scores. Copyright © 2016 Sociedad Española de Enfermería Intensiva y Unidades Coronarias (SEEIUC). Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Anomolous, intensity dependent losses in Au(32+) beams

    International Nuclear Information System (INIS)

    Blaskiewicz, M.; Ahrens, L.; Calvani, H.

    1997-01-01

    The AGS Booster is a rapid cycling proton and heavy ion synchrotron. Anomolous, intensity dependent losses in Au(32+) beams have been observed in the AGS Booster. No collective signal is expected, or observed, but increasing the number of injected ions decreases the beam lifetime. The loss rates for Au(32+) are compared with those for Au(15+)

  17. Attention-dependent modulation of cortical taste circuits revealed by Granger causality with signal-dependent noise.

    Directory of Open Access Journals (Sweden)

    Qiang Luo

    2013-10-01

    Full Text Available We show, for the first time, that in cortical areas, for example the insular, orbitofrontal, and lateral prefrontal cortex, there is signal-dependent noise in the fMRI blood-oxygen level dependent (BOLD time series, with the variance of the noise increasing approximately linearly with the square of the signal. Classical Granger causal models are based on autoregressive models with time invariant covariance structure, and thus do not take this signal-dependent noise into account. To address this limitation, here we describe a Granger causal model with signal-dependent noise, and a novel, likelihood ratio test for causal inferences. We apply this approach to the data from an fMRI study to investigate the source of the top-down attentional control of taste intensity and taste pleasantness processing. The Granger causality with signal-dependent noise analysis reveals effects not identified by classical Granger causal analysis. In particular, there is a top-down effect from the posterior lateral prefrontal cortex to the insular taste cortex during attention to intensity but not to pleasantness, and there is a top-down effect from the anterior and posterior lateral prefrontal cortex to the orbitofrontal cortex during attention to pleasantness but not to intensity. In addition, there is stronger forward effective connectivity from the insular taste cortex to the orbitofrontal cortex during attention to pleasantness than during attention to intensity. These findings indicate the importance of explicitly modeling signal-dependent noise in functional neuroimaging, and reveal some of the processes involved in a biased activation theory of selective attention.

  18. Functional magnetic resonance imaging of higher brain activity

    International Nuclear Information System (INIS)

    Cui He; Wang Yunjiu; Chen Runsheng; Tang Xiaowei.

    1996-01-01

    Functional magnetic resonance images (fMRIs) exhibit small differences in the magnetic resonance signal intensity in positions corresponding to focal areas of brain activation. These signal are caused by variation in the oxygenation state of the venous vasculature. Using this non-invasive and dynamic method, it is possible to localize functional brain activation, in vivo, in normal individuals, with an accuracy of millimeters and a temporal resolution of seconds. Though a series of technical difficulties remain, fMRI is increasingly becoming a key method for visualizing the working brain, and uncovering the topographical organization of the human brain, and understanding the relationship between brain and the mind

  19. Consideration of fluctuation in secondary beam intensity of heavy ion beam probe measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fujisawa, A.; Iguchi, H.; Lee, S.; Hamada, Y.

    1997-01-01

    Heavy ion beam probes have capability to detect local electron density fluctuation in the interior of plasmas through the detected beam intensity fluctuation. However, the intensity fluctuation should suffer a certain degree of distortion from electron density and temperature fluctuations on the beam orbits, and as a result the signal can be quite different from the local density fluctuation. This paper will present a condition that the intensity fluctuation can be regarded as being purely local electron density fluctuation, together with discussion about the contamination of the fluctuation along the beam orbits to the beam intensity fluctuation. (author)

  20. Multiple logistic regression model of signalling practices of drivers on urban highways

    Science.gov (United States)

    Puan, Othman Che; Ibrahim, Muttaka Na'iya; Zakaria, Rozana

    2015-05-01

    Giving signal is a way of informing other road users, especially to the conflicting drivers, the intention of a driver to change his/her movement course. Other users are exposed to hazard situation and risks of accident if the driver who changes his/her course failed to give signal as required. This paper describes the application of logistic regression model for the analysis of driver's signalling practices on multilane highways based on possible factors affecting driver's decision such as driver's gender, vehicle's type, vehicle's speed and traffic flow intensity. Data pertaining to the analysis of such factors were collected manually. More than 2000 drivers who have performed a lane changing manoeuvre while driving on two sections of multilane highways were observed. Finding from the study shows that relatively a large proportion of drivers failed to give any signals when changing lane. The result of the analysis indicates that although the proportion of the drivers who failed to provide signal prior to lane changing manoeuvre is high, the degree of compliances of the female drivers is better than the male drivers. A binary logistic model was developed to represent the probability of a driver to provide signal indication prior to lane changing manoeuvre. The model indicates that driver's gender, type of vehicle's driven, speed of vehicle and traffic volume influence the driver's decision to provide a signal indication prior to a lane changing manoeuvre on a multilane urban highway. In terms of types of vehicles driven, about 97% of motorcyclists failed to comply with the signal indication requirement. The proportion of non-compliance drivers under stable traffic flow conditions is much higher than when the flow is relatively heavy. This is consistent with the data which indicates a high degree of non-compliances when the average speed of the traffic stream is relatively high.

  1. Human cerebral cortices: signal variation on diffusion-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Asao, Chiaki [Kumamoto Regional Medical Center, Department of Radiology, Kumamoto (Japan); National Hospital Organization Kumamoto Medical Center, Department of Radiology, Kumamoto (Japan); Hirai, Toshinori; Yamashita, Yasuyuki [Kumamoto University Graduate School of Medical Sciences, Department of Diagnostic Radiology, Kumamoto (Japan); Yoshimatsu, Shunji [National Hospital Organization Kumamoto Medical Center, Department of Radiology, Kumamoto (Japan); Matsukawa, Tetsuya; Imuta, Masanori [Kumamoto Regional Medical Center, Department of Radiology, Kumamoto (Japan); Sagara, Katsuro [Kumamoto Regional Medical Center, Department of Internal Medicine, Kumamoto (Japan)

    2008-03-15

    We have often encountered high signal intensity (SI) of the cingulate gyrus and insula during diffusion-weighted magnetic resonance imaging (DW-MRI) on neurologically healthy adults. To date, cortical signal heterogeneity on DW images has not been investigated systematically. The purpose of our study was to determine whether there is regional signal variation in the brain cortices of neurologically healthy adults on DW-MR images. The SI of the cerebral cortices on DW-MR images at 1.5 T was evaluated in 50 neurologically healthy subjects (34 men, 16 women; age range 33-84 years; mean age 57.6 years). The cortical SI in the cingulate gyrus, insula, and temporal, occipital, and parietal lobes was graded relative to the SI of the frontal lobe. Contrast-to-noise ratios (CNRs) on DW-MR images were compared for each cortical area. Diffusion changes were analyzed by visually assessment of the differences in appearance among the cortices on apparent diffusion coefficient (ADC) maps. Increased SI was frequently seen in the cingulate gyrus and insula regardless of patient age. There were no significant gender- or laterality-related differences. The CNR was significantly higher in the cingulate gyrus and insula than in the other cortices (p <.01), and significant differences existed among the cortical regions (p <.001). There were no apparent ADC differences among the cortices on ADC maps. Regional signal variation of the brain cortices was observed on DW-MR images of healthy subjects, and the cingulate gyrus and insula frequently manifested high SI. These findings may help in the recognition of cortical signal abnormalities as visualized on DW-MR images. (orig.)

  2. Human cerebral cortices: signal variation on diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Asao, Chiaki; Hirai, Toshinori; Yamashita, Yasuyuki; Yoshimatsu, Shunji; Matsukawa, Tetsuya; Imuta, Masanori; Sagara, Katsuro

    2008-01-01

    We have often encountered high signal intensity (SI) of the cingulate gyrus and insula during diffusion-weighted magnetic resonance imaging (DW-MRI) on neurologically healthy adults. To date, cortical signal heterogeneity on DW images has not been investigated systematically. The purpose of our study was to determine whether there is regional signal variation in the brain cortices of neurologically healthy adults on DW-MR images. The SI of the cerebral cortices on DW-MR images at 1.5 T was evaluated in 50 neurologically healthy subjects (34 men, 16 women; age range 33-84 years; mean age 57.6 years). The cortical SI in the cingulate gyrus, insula, and temporal, occipital, and parietal lobes was graded relative to the SI of the frontal lobe. Contrast-to-noise ratios (CNRs) on DW-MR images were compared for each cortical area. Diffusion changes were analyzed by visually assessment of the differences in appearance among the cortices on apparent diffusion coefficient (ADC) maps. Increased SI was frequently seen in the cingulate gyrus and insula regardless of patient age. There were no significant gender- or laterality-related differences. The CNR was significantly higher in the cingulate gyrus and insula than in the other cortices (p <.01), and significant differences existed among the cortical regions (p <.001). There were no apparent ADC differences among the cortices on ADC maps. Regional signal variation of the brain cortices was observed on DW-MR images of healthy subjects, and the cingulate gyrus and insula frequently manifested high SI. These findings may help in the recognition of cortical signal abnormalities as visualized on DW-MR images. (orig.)

  3. Light intensity dependent optical rotation in azobenzene polymers

    Science.gov (United States)

    Ivanov, M.; Ilieva, D.; Petrova, T.; Dragostinova, V.; Todorov, T.; Nikolova, L.

    2006-05-01

    We investigate the self-induced rotation of the azimuth of light polarization ellipse in azobenzene polymers. It is initiated by the photoreorientation and ordering of the azobenzenes on illumination with elliptically polarized light resulting in the appearance of an optical axis whose direction is gradually rotated along the depth of the film. A macroscopic chiral structure is created with a pitch depending on light ellipticity and the photobirefringence ▵n in the successive layers of the film. In this work we make use of the fact that at elevated temperatures ▵n is very sensitive to light intensity. In our acrylic amorphous azobenzene polymer at temperatures 50-65°C the saturated values of ▵n are much higher for low intensity of the exciting light than for higher intensity. In this temperature range the polarization azimuth of monochromatic blue light with different intensity is rotated to a different angle after passing through the polymer film. This effect can be used for passive elements rotating the polarization azimuth depending on light intensity and for the formation of light beams with a space-variant polarization state.

  4. When less is best: female brown-headed cowbirds prefer less intense male displays.

    Science.gov (United States)

    O'Loghlen, Adrian L; Rothstein, Stephen I

    2012-01-01

    Sexual selection theory predicts that females should prefer males with the most intense courtship displays. However, wing-spread song displays that male brown-headed cowbirds (Molothrus ater) direct at females are generally less intense than versions of this display that are directed at other males. Because male-directed displays are used in aggressive signaling, we hypothesized that females should prefer lower intensity performances of this display. To test this hypothesis, we played audiovisual recordings showing the same males performing both high intensity male-directed and low intensity female-directed displays to females (N = 8) and recorded the females' copulation solicitation display (CSD) responses. All eight females responded strongly to both categories of playbacks but were more sexually stimulated by the low intensity female-directed displays. Because each pair of high and low intensity playback videos had the exact same audio track, the divergent responses of females must have been based on differences in the visual content of the displays shown in the videos. Preferences female cowbirds show in acoustic CSD studies are correlated with mate choice in field and captivity studies and this is also likely to be true for preferences elucidated by playback of audiovisual displays. Female preferences for low intensity female-directed displays may explain why male cowbirds rarely use high intensity displays when signaling to females. Repetitive high intensity displays may demonstrate a male's current condition and explain why these displays are used in male-male interactions which can escalate into physical fights in which males in poorer condition could be injured or killed. This is the first study in songbirds to use audiovisual playbacks to assess how female sexual behavior varies in response to variation in a male visual display.

  5. Interaction of Intense Lasers with Plasmas

    Science.gov (United States)

    Shvets, Gennady

    1995-01-01

    This thesis addresses two important topics in nonlinear laser plasma physics: the interaction of intense lasers with a non thermal homogeneous plasma, the excitation of laser wakefields in hollow plasma channels, and the stability of channel guided propagation of laser pulses. In the first half of this thesis a new theoretical approach to the nonlinear interaction of intense laser pulses with underdense plasmas is developed. Unlike previous treatments, this theory is three-dimensional, relativistically covariant, and does not assume that astudied. An experimental check of this calculation is suggested, based on the predicted non-linear polarization rotation (the second harmonic is emitted polarized perpendicularly to polarization of the incident signal). The concept of renormalization is applied to the plasma and electromagnetic radiation (photons and plasmons). To the lowest order, this corresponds to relativistically correcting the electron mass for its oscillation in an intense EM field and to replacing the vacuum dispersion relation by the usual relativistic plasma dispersion relation. This renormalization procedure is then carried to higher order in epsilon=omega_sp{p} {2}a^2/[(1+a^2/2)^ {3/2}omega^2]. This yields the nonlinear modification of the index of refraction of a strong electromagnetic wave and the dispersion of a weak probe in the presence of the wave. In the second part of this thesis the stability of short laser pulses propagating through parabolic channels and the wake excitation of hollow plasma channels are studied. The stability of a channel guided short laser pulse propagation is analyzed for the first time. Perturbations to the laser pulse are shown to modify the ponderomotive pressure, which distorts the dielectric properties of the plasma channel. The channel perturbation then further distorts the laser pulse. A set of coupled mode equations is derived, and a matrix dispersion relation is obtained analytically. The ponderomotive excitation

  6. The influence of laser pulse duration and energy on ICP-MS signal intensity, elemental fractionation, and particle size distribution in NIR fs-LA-ICP-MS

    Science.gov (United States)

    Diwakar, Prasoon K.; Harilal, Sivanandan S.; LaHaye, Nicole L.; Hassanein, Ahmed; Kulkarni, Pramod

    2015-01-01

    Laser parameters, typically wavelength, pulse width, irradiance, repetition rate, and pulse energy, are critical parameters which influence the laser ablation process and thereby influence the LA-ICP-MS signal. In recent times, femtosecond laser ablation has gained popularity owing to the reduction in fractionation related issues and improved analytical performance which can provide matrix-independent sampling. The advantage offered by fs-LA is due to shorter pulse duration of the laser as compared to the phonon relaxation time and heat diffusion time. Hence the thermal effects are minimized in fs-LA. Recently, fs-LA-ICP-MS demonstrated improved analytical performance as compared to ns-LA-ICP-MS, but detailed mechanisms and processes are still not clearly understood. Improvement of fs-LA-ICP-MS over ns-LA-ICP-MS elucidates the importance of laser pulse duration and related effects on the ablation process. In this study, we have investigated the influence of laser pulse width (40 fs to 0.3 ns) and energy on LA-ICP-MS signal intensity and repeatability using a brass sample. Experiments were performed in single spot ablation mode as well as rastering ablation mode to monitor the Cu/Zn ratio. The recorded ICP-MS signal was correlated with total particle counts generated during laser ablation as well as particle size distribution. Our results show the importance of pulse width effects in the fs regime that becomes more pronounced when moving from femtosecond to picosecond and nanosecond regimes. PMID:26664120

  7. The Eldicus prospective, observational study of triage decision making in European intensive care units. Part II: Intensive care benefit for the elderly

    DEFF Research Database (Denmark)

    Sprung, Charles L; Artigas, Antonio; Kesecioglu, Jozef

    2012-01-01

    on mortality and intensive care unit benefit, specifically for elderly patients. DESIGN:: Prospective, observational study of triage decisions from September 2003 until March 2005. SETTING:: Eleven intensive care units in seven European countries. PATIENTS:: All patients >18 yrs with an explicit request......RATIONALE:: Life and death triage decisions are made daily by intensive care unit physicians. Admission to an intensive care unit is denied when intensive care unit resources are constrained, especially for the elderly. OBJECTIVE:: To determine the effect of intensive care unit triage decisions...... care unit rejections than younger patients and have a higher mortality when admitted, the mortality benefit appears greater for the elderly. Physicians should consider changing their intensive care unit triage practices for the elderly....

  8. Mechanisms of Wnt signaling and control.

    Science.gov (United States)

    Grainger, Stephanie; Willert, Karl

    2018-03-30

    The Wnt signaling pathway is a highly conserved system that regulates complex biological processes across all metazoan species. At the cellular level, secreted Wnt proteins serve to break symmetry and provide cells with positional information that is critical to the patterning of the entire body plan. At the organismal level, Wnt signals are employed to orchestrate fundamental developmental processes, including the specification of the anterior-posterior body axis, induction of the primitive streak and ensuing gastrulation movements, and the generation of cell and tissue diversity. Wnt functions extend into adulthood where they regulate stem cell behavior, tissue homeostasis, and damage repair. Disruption of Wnt signaling activity during embryonic development or in adults results in a spectrum of abnormalities and diseases, including cancer. The molecular mechanisms that underlie the myriad of Wnt-regulated biological effects have been the subject of intense research for over three decades. This review is intended to summarize our current understanding of how Wnt signals are generated and interpreted. This article is categorized under: Biological Mechanisms > Cell Signaling Developmental Biology > Stem Cell Biology and Regeneration. © 2018 Wiley Periodicals, Inc.

  9. Modeling laser velocimeter signals as triply stochastic Poisson processes

    Science.gov (United States)

    Mayo, W. T., Jr.

    1976-01-01

    Previous models of laser Doppler velocimeter (LDV) systems have not adequately described dual-scatter signals in a manner useful for analysis and simulation of low-level photon-limited signals. At low photon rates, an LDV signal at the output of a photomultiplier tube is a compound nonhomogeneous filtered Poisson process, whose intensity function is another (slower) Poisson process with the nonstationary rate and frequency parameters controlled by a random flow (slowest) process. In the present paper, generalized Poisson shot noise models are developed for low-level LDV signals. Theoretical results useful in detection error analysis and simulation are presented, along with measurements of burst amplitude statistics. Computer generated simulations illustrate the difference between Gaussian and Poisson models of low-level signals.

  10. Effect of grazing frequency and intensity on Lolium perenne L ...

    African Journals Online (AJOL)

    ) system. Low frequency, low intensity grazing produced lower CDMD and herbage N levels than higher grazing frequencies and intensities. These differences were, however, generally small. Overall, levels of herbage digestibility (estimated ...

  11. Signals and systems with MATLAB

    CERN Document Server

    Yang, Won Young; Song, Ik H; Cho, Yong S

    2009-01-01

    Covers some of the theoretical foundations and mathematical derivations that can be used in higher-level related subjects such as signal processing, communication, and control, minimizing the mathematical difficulty and computational burden. This book illustrates the usage of MATLAB and Simulink for signal and system analysis and design.

  12. Decreased T2 signal in the thalami may be a sign of lysosomal storage disease

    International Nuclear Information System (INIS)

    Autti, Taina; Joensuu, Raimo; Aaberg, Laura

    2007-01-01

    Lysosomal disorders are rare and are caused by genetically transmitted lysosomal enzyme deficiencies. A decreased T2 signal in the thalamus has occasionally been reported. Because the finding of bilateral abnormal signal intensity of the thalamus on T2-weighted images has not been systematically reviewed, and its value as a diagnostic tool critically evaluated, we carried out a systematic review of the literature. Articles in English with 30 trios of keywords were collected from PubMed. Exclusion criteria were lack of conventional T2-weighted images in the protocol and not being a human study. Finally, 111 articles were included. The thalamus was considered affected only if mentioned in the text or in the figure legends. Some 117 patients with various lysosomal diseases and five patients with ceruloplasmin deficiency were reported to have a bilateral decrease in T2 signal intensity. At least one article reported a bilateral decrease in signal intensity of the thalami on T2-weighted images in association with GM1 and GM2 gangliosidosis and with Krabbe's disease, aspartylglucosaminuria, mannosidosis, fucosidosis, and mucolipidosis IV. Furthermore, thalamic alteration was a consistent finding in several types of neuronal ceroid lipofuscinosis (NCL) including CLN1 (infantile NCL), CLN2 (classic late infantile NCL), CLN3 (juvenile NCL), CLN5 (Finnish variant late infantile NCL), and CLN7 (Turkish variant late infantile NCL). A decrease in T2 signal intensity in the thalami seems to be a sign of lysosomal disease. (orig.)

  13. Wii Fit U intensity and enjoyment in adults.

    Science.gov (United States)

    Tripette, Julien; Murakami, Haruka; Ando, Takafumi; Kawakami, Ryoko; Tanaka, Noriko; Tanaka, Shigeho; Miyachi, Motohiko

    2014-08-26

    The Wii Fit series (Nintendo Inc., Japan) provides active video games (AVGs) to help adults to maintain a sufficient level of daily physical activity (PA). The second generation of home AVG consoles is now emerging with new game modalities (including a portable mini screen in the case of the new Wii U). The present study was performed to investigate the intensity and enjoyment of Wii Fit U games among adults. Metabolic equivalent (METs, i.e., intensity) of the Wii Fit U activities were evaluated using metabolic chambers in 16 sedentary adults (8 women and 8 men). A short version of the physical activity enjoyment scale was completed for each activity. Wii Fit U activities were distributed over a range from 2.2  ±  0.4 METs (Hula dance) to 4.7  ±  1.2 (Hip-hop dance). Seven activities were classified as light-intensity PA (game modality does not induce higher METs. Men exercised at higher intensities than women. There was no correlation between enjoyment and MET values in women or men. More and more moderate-intensity activities are available through video gaming, but the average intensity (3.2  ±  0.6) is still low. Users should be aware that AVGs alone cannot fulfill the recommendations for PA, and the video games industry still must innovate further to enhance gaming intensity and make the tool more attractive to health and fitness professionals.

  14. Qualitative analysis of intracranial CSF flow on cine-MR imaging, with special reference to signal ratio of CSF to fat tissue

    International Nuclear Information System (INIS)

    Kadowaki, Chikafusa; Hara, Mitsuhiro; Numoto, Mitsuo; Takeuchi, Kazuo; Saito, Isamu

    1993-01-01

    Cine magnetic resonance images (MR) dramatically demonstrate the pulsatile flow of cerebrospinal fluid (CSF) stimulated by the pulsatile motion of the brain following cardiac pulsation. Reduced signal intensity, frequently observed especially in the aqueduct of Sylvius, the third ventricle and the fourth ventricle, is believed to reflect the pulsatile motion of the CSF. Qualitative analysis of MR signal intensity of CSF on each cine frame is compared with CSF flow within the ventricles on real-time cine MR images. While the chronological changes in signal intensities of CSF within the ventricles show only marginal changes in signal intensity in the third ventricle related to downward flow of CSF passing through the foramen of Monro during the early stage of cardiac systole, these changes are thought to have no significant correlation with the CSF flow in the CSF pathway. The chronological changes in relative signal ratios, SR [signal intensities of CSF/signal intensities of fat] can show CSF flow and turbulence within the ventricles. Under normal conditions, within the third ventricle the SR decreases due to pulsatile CSF flow through the foramen of Monro during the early stage of cardiac systole, and decreases because of the flow of CSF from the anterior to the posterior part of the third ventricle, the downward flow of CSF through the aqueduct leads to a lower SR during cardiac diastole. These changes in the fourth ventricle are stimulated by the changes in SR in the third ventricle. The new method of analyzing chronological changes in the relative MR signal ratio of CSF to fat [SR] has the distinct advantage of providing an accurate evaluation of CSF dynamics, and it provides us with important diagnostic information leading to clarification of the pathophysiology of CSF dynamics. (author)

  15. Stochastic resonance for signal-modulated pump noise in a single-mode laser

    Institute of Scientific and Technical Information of China (English)

    Liangying Zhang; Li Cao; Fahui Zhu

    2006-01-01

    By adopting the gain-noise model of the single-mode laser in which with bias and periodical signals serve as inputs, combining with the effect of coloured pump noise, we use the linear approximation method to calculate the power spectrum and signal-to-noise ratio (SNR) of the laser intensity under the condition of pump noise and quantum noise cross-related in the form of δ function. It is found that with the change of pump noise correlation time, both SNR and the output power will occur stochastic resonance (SR). If the bias signal α is very small, changing the intensities of pump noise and quantum noise respectively does not lead to the appearance of SR in the SNR; while α increases to a certain number, SR appears.

  16. Myasthenic crisis patients who require intensive care unit management.

    Science.gov (United States)

    Sakaguchi, Hideya; Yamashita, Satoshi; Hirano, Teruyuki; Nakajima, Makoto; Kimura, En; Maeda, Yasushi; Uchino, Makoto

    2012-09-01

    The purpose of this report was to investigate predictive factors that necessitate intensive care in myasthenic crisis (MC). We retrospectively reviewed MC patients at our institution and compared ICU and ward management groups. Higher MG-ADL scale scores, non-ocular initial symptoms, infection-triggered findings, and higher MGFA classification were observed more frequently in the ICU group. In patients with these prognostic factors, better outcomes may be obtained with early institution of intensive care. Copyright © 2012 Wiley Periodicals, Inc.

  17. Signal noise/interferer combiner unit programmable (SINCUP)

    Science.gov (United States)

    Martinezdepison, Emilio

    1988-12-01

    The Signal Noise Interferer Combiner Unit Programmable (SINCUP) has been developed to facilitate laboratory performance testing of Very Low Frequency (VLF/Low Frequency (LF) receivers. To accomplish this, the unit allows the combining in controlled amounts of various real-world environmental and manmade interference with an information carrying signal. The externally modulated signal is combined with internally/externally generated Gaussian noise and/or with an internally/externally generated interferer. In order to test modern digital processing techniques, such as Adaptive Null Steering, Eigenvector Sorting, and Widrow-Hoff adaptive filters, SINCUP is capable of generating and meeting much higher signal-to-noise plus interference ratios than earlier channel simulators. The present software has been written to accommodate a dynamic signal-to-noise ratio (SNR) range from -60 to +60 dB. Higher dynamic range units could be implemented.

  18. The Signal Detection and Control Circuit Design for Confocal Auto-Focus System

    OpenAIRE

    Yin Liu; Jin Yu; Zeqiang Mo

    2016-01-01

    Based on the demands of Confocal Auto-Focus system, the implementation method of signal measurement circuit and control circuit is given. Using the high performance instrumental amplifier AD620BN, low noise precision FET Op amplifier AD795JRZ and ultralow offset voltage Op amplifier OP07EP, a signal measurement circuit used to converse the two differential light intensity signal to electric signal is designed. And a control circuit which takes MCU MSP430F149 as core processes the former signa...

  19. Low-Intensity Pulsed Ultrasound Enhances Nerve Growth Factor-Induced Neurite Outgrowth through Mechanotransduction-Mediated ERK1/2-CREB-Trx-1 Signaling.

    Science.gov (United States)

    Zhao, Lu; Feng, Yi; Hu, Hong; Shi, Aiwei; Zhang, Lei; Wan, Mingxi

    2016-12-01

    Enhancing the action of nerve growth factor (NGF) is a potential therapeutic approach to neural regeneration. To facilitate neural regeneration, we investigated whether combining low-intensity pulsed ultrasound (LIPUS) and NGF could promote neurite outgrowth, an essential process in neural regeneration. In the present study, PC12 cells were subjected to a combination of LIPUS (1 MHz, 30 or 50 mW/cm 2 , 20% duty cycle and 100-Hz pulse repetition frequency, 10 min every other day) and NGF (50 ng/mL) treatment, and then neurite outgrowth was compared. Our findings indicated that the combined treatment with LIPUS (50 mW/cm 2 ) and NGF (50 ng/mL) promotes neurite outgrowth that is comparable to that achieved by NGF (100 ng/mL) treatment alone. LIPUS significantly increased NGF-induced neurite length, but not neurite branching. These effects were attributed to the enhancing effects of LIPUS on NGF-induced phosphorylation of ERK1/2 and CREB and the expression of thioredoxin (Trx-1). Furthermore, blockage of stretch-activated ion channels with Gd 3+ suppressed the stimulating effects of LIPUS on NGF-induced neurite outgrowth and the downstream signaling activation. Taken together, our findings suggest that LIPUS enhances NGF-induced neurite outgrowth through mechanotransduction-mediated signaling of the ERK1/2-CREB-Trx-1 pathway. The combination of LIPUS and NGF could potentially be used for the treatment of nerve injury and neurodegenerative diseases. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  20. A Holocene Record of Monsoon Intensity From Speleothems in Flores, Indonesia

    Science.gov (United States)

    Griffiths, M. L.; Drysdale, R.; Gagan, M.; Ayliffe, L.; Zhao, J.; St. Pierre, E.; Hantoro, W.; Suwargadi, B.

    2007-12-01

    The Australasian monsoon is among the largest monsoon systems on Earth. The affected region experiences a marked seasonal cycle in winds and precipitation, similar to its Northern Hemisphere counterparts (e.g., Asian monsoons). The Australasian monsoon is the life blood of the millions of people of the Indonesian archipelago. Since the climate is the dominating factor controlling food production, it is of great significance and urgency that we gain a firmer grasp on the parameters that control variations in monsoon intensity. Precise uranium series dating of two actively growing speleothems measuring ~1.25 (LR06-B1) and ~1.61 (LR06-B3) meters in length from Liang Luar cave (Flores, eastern Indonesia), reveal basal ages of ~12,846±103 and 23,605±171 years respectively. In previous studies, stable isotope ratios (δ18O and δ13C) and trace element concentrations in speleothems have revealed past environmental change (e.g., Burns et al., 2001; Wang et al., 2001; Fleitmann et al., 2004; Drysdale et al., 2004).In monsoon-affected regions, the δ18O signal recorded in stalagmites seems to be dominated by the amount of precipitation (so-called `amount effect'), whereby more negative (positive) δ18O values indicate enhanced (diminished) precipitation. Preliminary results from LR06-B1 indicate that δ18O values show a general increase in monsoon intensity from the beginning of the record to ~2000 years BP: this more or less follows insolation changes over the Australian continent.Comparison of our record with D4 from Dongge Cave reveals an anticorrelation during the Holocene, further supporting the hypothesis that tropical monsoon intensity is largely controlled by changes in insolation in both the Northern and Southern Hemisphere. Examination of our δ13C record demonstrates a high-frequency signal superimposed on low- frequency variability which correlates with the reconstructed sunspot cycle: higher (lower) sunspot numbers, and hence increased solar activity

  1. MIMO Intensity-Modulation Channels: Capacity Bounds and High SNR Characterization

    KAUST Repository

    Chaaban, Anas

    2016-10-01

    The capacity of MIMO intensity modulation channels is studied. The nonnegativity of the transmit signal (intensity) poses a challenge on the precoding of the transmit signal, which limits the applicability of classical schemes in this type of channels. To resolve this issue, capacity lower bounds are developed by using precoding-free schemes. This is achieved by channel inversion or QR decomposition to convert the MIMO channel to a set of parallel channels. The achievable rate of a DC-offset SVD based scheme is also derived as a benchmark. Then, a capacity upper bound is derived and is shown to coincide with the achievable rate of the QR decomposition based scheme at high SNR, consequently characterizing the high-SNR capacity of the channel. The high-SNR gap between capacity and the achievable rates of the channel inversion and the DC-offset SVD based schemes is also characterized. Finally, the ergodic capacity of the channel is also briefly discussed.

  2. Time variations in geomagnetic intensity

    Science.gov (United States)

    Valet, Jean-Pierre

    2003-03-01

    After many years spent by paleomagnetists studying the directional behavior of the Earth's magnetic field at all possible timescales, detailed measurements of field intensity are now needed to document the variations of the entire vector and to analyze the time evolution of the field components. A significant step has been achieved by combining intensity records derived from archeological materials and from lava flows in order to extract the global field changes over the past 12 kyr. A second significant step was due to the emergence of coherent records of relative paleointensity using the remanent magnetization of sediments to retrace the evolution of the dipole field. A third step was the juxtaposition of these signals with those derived from cosmogenic isotopes. Contemporaneous with the acquisition of records, new techniques have been developed to constrain the geomagnetic origin of the signals. Much activity has also been devoted to improving the quality of determinations of absolute paleointensity from volcanic rocks with new materials, proper selection of samples, and investigations of complex changes in magnetization during laboratory experiments. Altogether these developments brought us from a situation where the field changes were restricted to the past 40 kyr to the emergence of a coherent picture of the changes in the geomagnetic dipole moment for at least the past 1 Myr. On longer timescales the field variability and its average behavior is relatively well documented for the past 400 Myr. Section 3 gives a summary of most methods and techniques that are presently used to track the field intensity changes in the past. In each case, current limits and potential promises are discussed. The section 4 describes the field variations measured so far over various timescales covered by the archeomagnetic and the paleomagnetic records. Preference has always been given to composite records and databases in order to extract and discuss major and global geomagnetic

  3. Effects of light intensity on components and topographical structures of extracellular polysaccharides from the cyanobacteria Nostoc sp.

    Science.gov (United States)

    Ge, Hongmei; Xia, Ling; Zhou, Xuping; Zhang, Delu; Hu, Chunxiang

    2014-02-01

    A study on the effects of light intensity (40 and 80 μE/m(2)/sec) on the components and topographical structures of extracellular polysaccharides (EPS) was carried out in cyanobacteria Nostoc sp.. EPS yield increased with light intensity. However, light intensity did not significantly affect the EPS fractions and monosaccharide composition. Higher light intensity generally resulted in higher protein content of EPS in similar fractions. The topographical structure of EPS, investigated by atomic force microscopy, appeared as spherical lumps, chains and networks. The long chains were observed at higher light intensity. Thus, light intensity affected the yield and nature of EPS.

  4. A simple 5-DoF MR-compatible motion signal measurement system.

    Science.gov (United States)

    Chung, Soon-Cheol; Kim, Hyung-Sik; Yang, Jae-Woong; Lee, Su-Jeong; Choi, Mi-Hyun; Kim, Ji-Hye; Yeon, Hong-Won; Park, Jang-Yeon; Yi, Jeong-Han; Tack, Gye-Rae

    2011-09-01

    The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and power supply were located in a shielded case, which was made of copper and aluminum. The motion signal was modulated to an optic signal using pulse width modulation, and the modulated optic signal was transmitted outside the MR shield room using a high-intensity light-emitting diode and an optic cable. The motion signal was recorded on a PC by demodulating the transmitted optic signal into an electric signal. Various kinematic variables, such as angle, acceleration, velocity, and jerk, can be measured or calculated by using the motion measurement system developed here. This system also enables motion tracking by extracting the position information from the motion signals. It was verified that MR images and motion signals could reliably be measured simultaneously.

  5. A molecular-sized optical logic circuit for digital modulation of a fluorescence signal

    Science.gov (United States)

    Nishimura, Takahiro; Tsuchida, Karin; Ogura, Yusuke; Tanida, Jun

    2018-03-01

    Fluorescence measurement allows simultaneous detection of multiple molecular species by using spectrally distinct fluorescence probes. However, due to the broad spectra of fluorescence emission, the multiplicity of fluorescence measurement is generally limited. To overcome this limitation, we propose a method to digitally modulate fluorescence output signals with a molecular-sized optical logic circuit by using optical control of fluorescence resonance energy transfer (FRET). The circuit receives a set of optical inputs represented with different light wavelengths, and then it switches high and low fluorescence intensity from a reporting molecule according to the result of the logic operation. By using combinational optical inputs in readout of fluorescence signals, the number of biomolecular species that can be identified is increased. To implement the FRET-based circuits, we designed two types of basic elements, YES and NOT switches. An YES switch produces a high-level output intensity when receiving a designated light wavelength input and a low-level intensity without the light irradiation. A NOT switch operates inversely to the YES switch. In experiments, we investigated the operation of the YES and NOT switches that receive a 532-nm light input and modulate the fluorescence intensity of Alexa Fluor 488. The experimental result demonstrates that the switches can modulate fluorescence signals according to the optical input.

  6. MIMO processing based on higher-order Poincaré spheres

    Science.gov (United States)

    Fernandes, Gil M.; Muga, Nelson J.; Pinto, Armando N.

    2017-08-01

    A multi-input multi-output (MIMO) algorithm based on higher-order Poincaré spheres is demonstrated for space-division multiplexing (SDM) systems. The MIMO algorithm is modulation format agnostic, robust to frequency offset and does not require training sequences. In this approach, the space-multiplexed signal is decomposed in sets of two tributary signals, with each set represented in a higher-order Poincaré sphere. For any arbitrary complex modulation format, the samples of two tributaries can be represented in a given higher-order Poincaré sphere with a symmetry plane. The crosstalk along propagation changes the spatial orientation of this plane and, therefore, it can be compensated by computing and realigning the best fit plane. We show how the transmitted signal can be successfully recovered using this procedure for all possible combinations of tributaries. Moreover, we analyze the convergence speed for the MIMO technique considering several optical-to-noise ratios.

  7. Activated protein synthesis and suppressed protein breakdown signaling in skeletal muscle of critically ill patients.

    Directory of Open Access Journals (Sweden)

    Jakob G Jespersen

    Full Text Available BACKGROUND: Skeletal muscle mass is controlled by myostatin and Akt-dependent signaling on mammalian target of rapamycin (mTOR, glycogen synthase kinase 3β (GSK3β and forkhead box O (FoxO pathways, but it is unknown how these pathways are regulated in critically ill human muscle. To describe factors involved in muscle mass regulation, we investigated the phosphorylation and expression of key factors in these protein synthesis and breakdown signaling pathways in thigh skeletal muscle of critically ill intensive care unit (ICU patients compared with healthy controls. METHODOLOGY/PRINCIPAL FINDINGS: ICU patients were systemically inflamed, moderately hyperglycemic, received insulin therapy, and showed a tendency to lower plasma branched chain amino acids compared with controls. Using Western blotting we measured Akt, GSK3β, mTOR, ribosomal protein S6 kinase (S6k, eukaryotic translation initiation factor 4E binding protein 1 (4E-BP1, and muscle ring finger protein 1 (MuRF1; and by RT-PCR we determined mRNA expression of, among others, insulin-like growth factor 1 (IGF-1, FoxO 1, 3 and 4, atrogin1, MuRF1, interleukin-6 (IL-6, tumor necrosis factor α (TNF-α and myostatin. Unexpectedly, in critically ill ICU patients Akt-mTOR-S6k signaling was substantially higher compared with controls. FoxO1 mRNA was higher in patients, whereas FoxO3, atrogin1 and myostatin mRNAs and MuRF1 protein were lower compared with controls. A moderate correlation (r2=0.36, p<0.05 between insulin infusion dose and phosphorylated Akt was demonstrated. CONCLUSIONS/SIGNIFICANCE: We present for the first time muscle protein turnover signaling in critically ill ICU patients, and we show signaling pathway activity towards a stimulation of muscle protein synthesis and a somewhat inhibited proteolysis.

  8. Research on the Effect of Electrical Signals on Growth of Sansevieria under Light-Emitting Diode (LED Lighting Environment.

    Directory of Open Access Journals (Sweden)

    Liguo Tian

    Full Text Available The plant electrical signal has some features, e.g. weak, low-frequency and time-varying. To detect changes in plant electrical signals, LED light source was used to create a controllable light environment in this study. The electrical signal data were collected from Sansevieria leaves under the different illumination conditions, and the data was analyzed in time domain, frequency domain and time-frequency domain, respectively. These analyses are helpful to explore the relationship between changes in the light environment and electrical signals in Sansevieria leaves. The changes in the plant electrical signal reflected the changes in the intensity of photosynthesis. In this study, we proposed a new method to express plant photosynthetic intensity as a function of the electrical signal. That is, the plant electrical signal can be used to describe the state of plant growth.

  9. Research on the Effect of Electrical Signals on Growth of Sansevieria under Light-Emitting Diode (LED) Lighting Environment

    Science.gov (United States)

    Tian, Liguo; Meng, Qinghao; Wang, Liping; Dong, Jianghui; Wu, Hai

    2015-01-01

    The plant electrical signal has some features, e.g. weak, low-frequency and time-varying. To detect changes in plant electrical signals, LED light source was used to create a controllable light environment in this study. The electrical signal data were collected from Sansevieria leaves under the different illumination conditions, and the data was analyzed in time domain, frequency domain and time–frequency domain, respectively. These analyses are helpful to explore the relationship between changes in the light environment and electrical signals in Sansevieria leaves. The changes in the plant electrical signal reflected the changes in the intensity of photosynthesis. In this study, we proposed a new method to express plant photosynthetic intensity as a function of the electrical signal. That is, the plant electrical signal can be used to describe the state of plant growth. PMID:26121469

  10. Diode readout electronics for beam intensity and position monitors for FELs

    International Nuclear Information System (INIS)

    Herrmann, S; Hart, P; Freytag, M; Pines, J; Weaver, M; Sapozhnikov, L; Nelson, S; Koglin, J; Carini, G A; Tomada, A; Haller, G

    2014-01-01

    LCLS uses Intensity-Position Monitors (IPM) to measure intensity and position of the FEL x-ray pulses. The primary beam passes through a silicon nitride film and four diodes, arranged in quadrants, detect the backscattered x-ray photons. The position is derived from the relative intensity of the four diodes, while the sum provides beam intensity information. In contrast to traditional synchrotron beam monitors, where diodes measure a DC current signal, the LCLS beam monitors have to cope with the pulsed nature of the FEL, which requires a large single shot dynamic range. A key component of these beam monitors is the readout electronics. The first generation of beam monitors showed some limitations. A new scheme with upgraded electronics, firmware and software was implemented resulting in a more robust and reliable measuring tool.

  11. Neuropsychological significance of areas of high signal intensity on brain MRIs of children with neurofibromatosis.

    Science.gov (United States)

    Moore, B D; Slopis, J M; Schomer, D; Jackson, E F; Levy, B M

    1996-06-01

    Of children with neurofibromatosis (NF), 40% have a cognitive or learning impairment. Approximately 60% also have anomalous areas of high signal intensity on T2-weighted brain MRIs. The association of these hyperintensities and neuropsychological status is not fully understood. We administered a battery of neuropsychological tests and a standard clinical MRI to determine the impact of hyperintensity presence, number, and location on cognitive status in 84 children (8 to 16 years) with NF type 1. These children underwent standard clinical MRI using a GE 1.5-tesla scanner (except one child who was examined with a 1.0-tesla scanner). We conducted three types of analyses: Hyperintensity presence or absence.-Scores of children with (55%) and without hyperintensities (45%) were compared using t tests. No statistically significant differences between groups in intellectual functioning or any neuropsychological variable were found. Number of hyperintensities-The number of hyperintensity locations per child ranged from one to five (mean = 2.22). Pearson correlations revealed no significant association between the number of hyperintensities and neuropsychological performance. Location of hyperintensities-In four of the five locations studied, no statistically significant differences were found between scores of children with a hyperintensity in an area and those with one elsewhere. However, mean scores for IQ, Memory, Motor, Distractibility, and Attention domains for children with hyperintensities in the thalamus were significantly lower than scores for those with hyperintensities elsewhere. These results suggest that the simple presence or absence of hyperintensities, or their total number, is not as important as their anatomic location for detecting their relationship with neuropsychological status. Taking location into account, hyperintensities in the cerebral hemispheres, basal ganglia, brainstem, or cerebellum seem to have no impact on neuropsychological functioning

  12. Simulation of X-ray signals

    International Nuclear Information System (INIS)

    Weller, A.

    1980-12-01

    A parameterized form of the local emissivity is used for the simulation of soft X-ray signals obtained on the WENDELSTEIN W VII-A stellarator with a 30 diode array. Numerical calculation of the line integrals for the different viewing angles and for a set of rotation angles covering one full signal period provides simulated periodic signals. In addition radial profiles of the line integrated emmission averaged over some time interval or at specific times, the relative amplitude modulation and the relative phase of the oscillations are calculated. These have to be fitted to the corresponding measured signals and profiles in order to get a reliable picture of the local emissivity. The model can take into account two poloidally asymmetric contributions of the type m = 1,2,3 or 4 (m = poloidal mode number). Each asymmetry can be generated in two ways (modulation of intensity and of geometry parameters). Besides an uniform rotation of the asymmetric terms some specific simple time evolution of the signals can be included (non-uniform rotation, growth of oscillations, sawtooth oscillations). The various input parameters are illustrated and the result of a simulation procedure is presented for a particular discharge in W VII-A. (orig.)

  13. A method of simulating intensity modulation-direct detection WDM systems

    Institute of Scientific and Technical Information of China (English)

    HUANG Jing; YAO Jian-quan; LI En-bang

    2005-01-01

    In the simulation of Intensity Modulation-Direct Detection WDM Systems,when the dispersion and nonlinear effects play equally important roles,the intensity fluctuation caused by cross-phase modulation may be overestimated as a result of the improper step size.Therefore,the step size in numerical simulation should be selected to suppress false XPM intensity modulation (keep it much less than signal power).According to this criterion,the step size is variable along the fiber.For a WDM system,the step size depends on the channel separation.Different type of transmission fiber has different step size.In the split-step Fourier method,this criterion can reduce simulation time,and when the step size is bigger than 100 meters,the simulation accuracy can also be improved.

  14. Work intensity in sacroiliac joint fusion and lumbar microdiscectomy

    Science.gov (United States)

    Frank, Clay; Kondrashov, Dimitriy; Meyer, S Craig; Dix, Gary; Lorio, Morgan; Kovalsky, Don; Cher, Daniel

    2016-01-01

    Background The evidence base supporting minimally invasive sacroiliac (SI) joint fusion (SIJF) surgery is increasing. The work relative value units (RVUs) associated with minimally invasive SIJF are seemingly low. To date, only one published study describes the relative work intensity associated with minimally invasive SIJF. No study has compared work intensity vs other commonly performed spine surgery procedures. Methods Charts of 192 patients at five sites who underwent either minimally invasive SIJF (American Medical Association [AMA] CPT® code 27279) or lumbar microdiscectomy (AMA CPT® code 63030) were reviewed. Abstracted were preoperative times associated with diagnosis and patient care, intraoperative parameters including operating room (OR) in/out times and procedure start/stop times, and postoperative care requirements. Additionally, using a visual analog scale, surgeons estimated the intensity of intraoperative care, including mental, temporal, and physical demands and effort and frustration. Work was defined as operative time multiplied by task intensity. Results Patients who underwent minimally invasive SIJF were more likely female. Mean procedure times were lower in SIJF by about 27.8 minutes (P<0.0001) and mean total OR times were lower by 27.9 minutes (P<0.0001), but there was substantial overlap across procedures. Mean preservice and post-service total labor times were longer in minimally invasive SIJF (preservice times longer by 63.5 minutes [P<0.0001] and post-service labor times longer by 20.2 minutes [P<0.0001]). The number of postoperative visits was higher in minimally invasive SIJF. Mean total service time (preoperative + OR time + postoperative) was higher in the minimally invasive SIJF group (261.5 vs 211.9 minutes, P<0.0001). Intraoperative intensity levels were higher for mental, physical, effort, and frustration domains (P<0.0001 each). After taking into account intensity, intraoperative workloads showed substantial overlap. Conclusion

  15. Signaling in large-scale neural networks

    DEFF Research Database (Denmark)

    Berg, Rune W; Hounsgaard, Jørn

    2009-01-01

    We examine the recent finding that neurons in spinal motor circuits enter a high conductance state during functional network activity. The underlying concomitant increase in random inhibitory and excitatory synaptic activity leads to stochastic signal processing. The possible advantages of this m......We examine the recent finding that neurons in spinal motor circuits enter a high conductance state during functional network activity. The underlying concomitant increase in random inhibitory and excitatory synaptic activity leads to stochastic signal processing. The possible advantages...... of this metabolically costly organization are analyzed by comparing with synaptically less intense networks driven by the intrinsic response properties of the network neurons....

  16. Calibration and Process of Signal of Photomultiplier Tube in Rayleigh Scattering of Supersonic Jet Clusters

    International Nuclear Information System (INIS)

    Lu Jianfeng; Liu Meng; Han Jifeng; Li Jia; Luo Xiaobing; Miao Jingwei; Yang Chaowen

    2009-01-01

    In the experiments of Rayleigh scattering of gas-jet clusters, the signal amplitude of PMT is not only affected by duster itself, but also by the intensity of light source and work voltage of PMT. When the back pressure of cluster source varies from 10 atm to about 100atm, the signal amplitude of PMT may be from linear to nonlinear. In order to solve the problem, signal calibration of PMT under different intensifies of light and voltage of PMT has been done. The relationship between the amplitude of signal and intensities of light as well as voltage of PMT has been obtained. The function of scatter factor of Ar clusters with the back pressure of cluster source is gotten experimentally, and agrees with related experimental and theoretical results. (authors)

  17. Electronic signal conditioning

    CERN Document Server

    NEWBY, BRUCE

    1994-01-01

    At technician level, brief references to signal conditioning crop up in a fragmented way in various textbooks, but there has been no single textbook, until now!More advanced texts do exist but they are more mathematical and presuppose a higher level of understanding of electronics and statistics. Electronic Signal Conditioning is designed for HNC/D students and City & Guilds Electronics Servicing 2240 Parts 2 & 3. It will also be useful for BTEC National, Advanced GNVQ, A-level electronics and introductory courses at degree level.

  18. Analysis and comparison model for measuring tropospheric scintillation intensity for Ku-band frequency in Malaysia

    Directory of Open Access Journals (Sweden)

    Mandeep JS

    2011-06-01

    Full Text Available This study has been based on understanding local propagation signal data distribution characteristics and identifying and predicting the overall impact of significant attenuating factors regarding the propagation path such as impaired propagation for a signal being transmitted. Predicting propagation impairment is important for accurate link budgeting, thereby leading to better communication network system designation. This study has thus used sample data for one year concerning beacon satellite operation in Malaysia from April 2008 to April 2009. Data concerning 12GHz frequency (Ku-band and 40° elevation angle was collected and analysed, obtaining average signal amplitude value, ÷ and also standard deviation ó which is normally measured in dB to obtain long-term scintillation intensity distribution. This analysis showed that scintillation intensity distribution followed Gaussian distribution for long-term data distribution. A prediction model was then selected based on the above; Karasawa,
    ITU-R, Van de Kamp and Otung models were compared to obtain the best prediction model performance for selected data regarding specific meteorological conditions. This study showed that the Karasawa model had the best performance for predicting scintillation intensity for the selected da ta.

  19. A note on measurement of sound pressure with intensity probes

    DEFF Research Database (Denmark)

    Juhl, Peter; Jacobsen, Finn

    2004-01-01

    be improved under a variety of realistic sound field conditions by applying a different weighting of the two pressure signals from the probe. The improved intensity probe can measure the sound pressure more accurately at high frequencies than an ordinary sound intensity probe or an ordinary sound level meter......The effect of scattering and diffraction on measurement of sound pressure with "two-microphone" sound intensity probes is examined using an axisymmetric boundary element model of the probe. Whereas it has been shown a few years ago that the sound intensity estimated with a two-microphone probe...... is reliable up to 10 kHz when using 0.5 in. microphones in the usual face-to-face arrangement separated by a 12 mm spacer, the sound pressure measured with the same instrument will typically be underestimated at high frequencies. It is shown in this paper that the estimate of the sound pressure can...

  20. Intensity correlation imaging with sunlight-like source

    Science.gov (United States)

    Wang, Wentao; Tang, Zhiguo; Zheng, Huaibin; Chen, Hui; Yuan, Yuan; Liu, Jinbin; Liu, Yanyan; Xu, Zhuo

    2018-05-01

    We show a method of intensity correlation imaging of targets illuminated by a sunlight-like source both theoretically and experimentally. With a Faraday anomalous dispersion optical filter (FADOF), we have modulated the coherence time of a thermal source up to 0.167 ns. And we carried out measurements of temporal and spatial correlations, respectively, with an intensity interferometer setup. By skillfully using the even Fourier fitting on the very sparse sampling data, the images of targets are successfully reconstructed from the low signal-noise-ratio(SNR) interference pattern by applying an iterative phase retrieval algorithm. The resulting imaging quality is as well as the one obtained by the theoretical fitting. The realization of such a case will bring this technique closer to geostationary satellite imaging illuminated by sunlight.

  1. The truthful signalling hypothesis: an explicit general equilibrium model.

    Science.gov (United States)

    Hausken, Kjell; Hirshleifer, Jack

    2004-06-21

    In mating competition, the truthful signalling hypothesis (TSH), sometimes known as the handicap principle, asserts that higher-quality males signal while lower-quality males do not (or else emit smaller signals). Also, the signals are "believed", that is, females mate preferentially with higher-signalling males. Our analysis employs specific functional forms to generate analytic solutions and numerical simulations that illuminate the conditions needed to validate the TSH. Analytic innovations include: (1) A Mating Success Function indicates how female mating choices respond to higher and lower signalling levels. (2) A congestion function rules out corner solutions in which females would mate exclusively with higher-quality males. (3) A Malthusian condition determines equilibrium population size as related to per-capita resource availability. Equilibria validating the TSH are achieved over a wide range of parameters, though not universally. For TSH equilibria it is not strictly necessary that the high-quality males have an advantage in terms of lower per-unit signalling costs, but a cost difference in favor of the low-quality males cannot be too great if a TSH equilibrium is to persist. And although the literature has paid less attention to these points, TSH equilibria may also fail if: the quality disparity among males is too great, or the proportion of high-quality males in the population is too large, or if the congestion effect is too weak. Signalling being unprofitable in aggregate, it can take off from a no-signalling equilibrium only if the trait used for signalling is not initially a handicap, but instead is functionally useful at low levels. Selection for this trait sets in motion a bandwagon, whereby the initially useful indicator is pushed by male-male competition into the domain where it does indeed become a handicap.

  2. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals.

    Science.gov (United States)

    Xiong, Jiping; Cai, Lisang; Wang, Fei; He, Xiaowei

    2017-03-03

    Although wrist-type photoplethysmographic (hereafter referred to as WPPG) sensor signals can measure heart rate quite conveniently, the subjects' hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  3. Attending to weak signals: the leader's challenge.

    Science.gov (United States)

    Kerfoot, Karlene

    2005-12-01

    Halverson and Isham (2003) quote sources that report the accidental death rate of simply being in a hospital is " ... four hundred times more likely than your risk of death from traveling by train, forty times higher than driving a car, and twenty times higher than flying in a commercial aircraft" (p. 13). High-reliability organizations such as nuclear power plants and aircraft carriers have been pioneers in the business of recognizing weak signals. Weike and Sutcliffe (2001) note that high-reliability organizations distinguish themselves from others because of their mindfulness which enables them to see the significance of weak signals and to give strong interventions to weak signals. To act mindfully, these organizations have an underlying mental model of continually updating, anticipating, and focusing the possibility of failure using the intelligence that weak signals provides. Much of what happens is unexpected in health care. However, with a culture that is continually looking for weak signals, and intervenes and rescues when these signals are detected, the unexpected happens less often. This is the epitome of how leaders can build a culture of safety that focuses on recognizing the weak signals to manage the unforeseen.

  4. The intensity of precipitation during extratropical cyclones in global warming simulations: a link to cyclone intensity?

    Energy Technology Data Exchange (ETDEWEB)

    Watterson, I.G. [CSIRO Atmospheric Research, Aspendale (Australia)

    2006-01-01

    Simulations of global warming over the coming century from two CSIRO GCMs are analysed to assess changes in the intensity of extratropical cyclones, and the potential role of increased latent heating associated with precipitation during cyclones. A simple surface cyclone detection scheme is applied to a four-member ensemble of simulations from the Mark 2 GCM, under rising greenhouse gas concentrations. The seasonal distribution of cyclones appears broadly realistic during 1961-1990. By 2071-2100, with 3 K global warming, numbers over 20 deg N to 70 deg N decrease by 6% in winter and 2% annually, with similar results for the south. The average intensity of cyclones, from relative central pressure and other measures, is largely unchanged however. 30-yr extremes of dynamic intensity also show little clear change, including values averaged over continents. Mean rain rates at cyclone centres are typically at least double rates from all days. Rates during cyclones increase by an average 14% in the northern winter under global warming. Rates over adjacent grid squares and during the previous day increase similarly, as do extreme rates. Results from simulations of the higher-resolution (1.8 deg grid) Mark 3 GCM are similar, with widespread increases in rain rates but not in cyclone intensity. The analyses suggest that latent heating during storms increases, as anticipated due to the increased moisture capacity of the warmer atmosphere. However, any role for enhanced heating in storm development in the GCMs is apparently masked by other factors. An exception is a 5% increase in extreme intensity around 55 deg S in Mark 3, despite decreased numbers of lows, a factor assessed using extreme value theory. Further studies with yet higher-resolution models may be needed to examine the potential realism of these results, particularly with regard to extremes at smaller scale.

  5. Physician work intensity among medical specialties: emerging evidence on its magnitude and composition.

    Science.gov (United States)

    Horner, Ronnie D; Szaflarski, Jerzy P; Ying, Jun; Meganathan, Karthikeyan; Matthews, Gerald; Schroer, Brian; Weber, Debra; Raphaelson, Marc

    2011-11-01

    Similarities and differences in physician work intensity among specialties are poorly understood but have implications for quality of care, patient safety, practice organization and management, and payment. To determine the magnitude and important dimensions of physician work intensity for 4 specialties. Cross-sectional assessment of work intensity associated with actual patient care in the examination room or operating room. A convenience sample of 45 family physicians, 20 general internists, 22 neurologists, and 21 surgeons, located in Kansas, Kentucky, Maryland, Ohio, and Virginia. Work intensity measures included the National Aeronautics and Space Administration-Task Load Index (NASA-TLX), Subjective Work Assessment Technique (SWAT), and Multiple Resource Questionnaire. Stress was measured by the Dundee Stress State Questionnaire. Physicians reported similar magnitude of work intensity on the NASA-TLX and Multiple Resource Questionnaire. On the SWAT, general internists reported work intensity similar to surgeons but significantly lower than family physicians and neurologists (P=0.035). Surgeons reported significantly higher levels of task engagement on the stress measure than the other specialties (P=0.019), significantly higher intensity on physical demand (P NASA-TLX than the other specialties (P=0.003). Surgeons reported the lowest intensity for temporal demand of all specialties, being significantly lower than either family physicians or neurologists (P=0.014). Family physicians reported the highest intensity on the time dimension of the SWAT, being significantly higher than either general internists or surgeons (P=0.008). Level of physician work intensity seems to be similar among specialties.

  6. Reveal or Conceal? Signaling Strategies for Building Legitimacy in Cleantech Firms

    Directory of Open Access Journals (Sweden)

    Ekaterina S. Bjornali

    2017-10-01

    Full Text Available New entrants in technology-intense industries are in a race to build legitimacy in order to compete with established players. Legitimacy has been identified as a driver of venture survival and growth; it helps mitigate third-party uncertainty and so facilitates access to resources, engagement with customers and other stakeholders. Nevertheless, we know little about how legitimacy is built and how new entrants build legitimacy in complex technology-intensive industries. In this research we explore how Norwegian cleantech firms use signaling and strategic actions to build legitimacy. We analyze five cases while investigating their actions in different phases of the venture’s evolution. The results suggest that, contrary to signaling theory expectations, young clean-tech firms do not always build legitimacy by conveying information on their strengths. Instead, we observe that they use signaling strategies to address the specific concerns of different stakeholders. This is very much contingent upon the evolutionary stage of the venture and the firm’s current weaknesses.

  7. Optimized lighting method of applying shaped-function signal for increasing the dynamic range of LED-multispectral imaging system

    Science.gov (United States)

    Yang, Xue; Hu, Yajia; Li, Gang; Lin, Ling

    2018-02-01

    This paper proposes an optimized lighting method of applying a shaped-function signal for increasing the dynamic range of light emitting diode (LED)-multispectral imaging system. The optimized lighting method is based on the linear response zone of the analog-to-digital conversion (ADC) and the spectral response of the camera. The auxiliary light at a higher sensitivity-camera area is introduced to increase the A/D quantization levels that are within the linear response zone of ADC and improve the signal-to-noise ratio. The active light is modulated by the shaped-function signal to improve the gray-scale resolution of the image. And the auxiliary light is modulated by the constant intensity signal, which is easy to acquire the images under the active light irradiation. The least square method is employed to precisely extract the desired images. One wavelength in multispectral imaging based on LED illumination was taken as an example. It has been proven by experiments that the gray-scale resolution and the accuracy of information of the images acquired by the proposed method were both significantly improved. The optimum method opens up avenues for the hyperspectral imaging of biological tissue.

  8. Cleavable DNA-protein hybrid molecular beacon: A novel efficient signal translator for sensitive fluorescence anisotropy bioassay.

    Science.gov (United States)

    Hu, Pan; Yang, Bin

    2016-01-15

    Due to its unique features such as high sensitivity, homogeneous format, and independence on fluorescent intensity, fluorescence anisotropy (FA) assay has become a hotspot of study in oligonucleotide-based bioassays. However, until now most FA probes require carefully customized structure designs, and thus are neither generalizable for different sensing systems nor effective to obtain sufficient signal response. To address this issue, a cleavable DNA-protein hybrid molecular beacon was successfully engineered for signal amplified FA bioassay, via combining the unique stable structure of molecular beacon and the large molecular mass of streptavidin. Compared with single DNA strand probe or conventional molecular beacon, the DNA-protein hybrid molecular beacon exhibited a much higher FA value, which was potential to obtain high signal-background ratio in sensing process. As proof-of-principle, this novel DNA-protein hybrid molecular beacon was further applied for FA bioassay using DNAzyme-Pb(2+) as a model sensing system. This FA assay approach could selectively detect as low as 0.5nM Pb(2+) in buffer solution, and also be successful for real samples analysis with good recovery values. Compatible with most of oligonucleotide probes' designs and enzyme-based signal amplification strategies, the molecular beacon can serve as a novel signal translator to expand the application prospect of FA technology in various bioassays. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Performance Characteristics Of An Intensity Modulated Advanced X-Ray Source (IMAXS) For Homeland Security Applications

    International Nuclear Information System (INIS)

    Langeveld, Willem G. J.; Brown, Craig; Condron, Cathie; Ingle, Mike; Christensen, Phil A.; Johnson, William A.; Owen, Roger D.; Hernandez, Michael; Schonberg, Russell G.; Ross, Randy

    2011-01-01

    X-ray cargo inspection systems for the detection and verification of threats and contraband must address stringent, competitive performance requirements. High x-ray intensity is needed to penetrate dense cargo, while low intensity is desirable to minimize the radiation footprint, i.e. the size of the controlled area, required shielding and the dose to personnel. In a collaborative effort between HESCO/PTSE Inc., XScell Corp., Stangenes Industries, Inc. and Rapiscan Laboratories, Inc., an Intensity Modulated Advanced X-ray Source (IMAXS) was designed and produced. Cargo inspection systems utilizing such a source have been projected to achieve up to 2 inches steel-equivalent greater penetration capability, while on average producing the same or smaller radiation footprint as present fixed-intensity sources. Alternatively, the design can be used to obtain the same penetration capability as with conventional sources, but reducing the radiation footprint by about a factor of three. The key idea is to anticipate the needed intensity for each x-ray pulse by evaluating signal strength in the cargo inspection system detector array for the previous pulse. The IMAXS is therefore capable of changing intensity from one pulse to the next by an electronic signal provided by electronics inside the cargo inspection system detector array, which determine the required source intensity for the next pulse. We report on the completion of a 9 MV S-band (2998 MHz) IMAXS source and comment on its performance.

  10. To signal or not to signal: that should not be the question.

    Science.gov (United States)

    Faw, Harold W

    2013-10-01

    The purpose of the present research was to examine rates of turn signal use, a positive and potentially valuable means by which drivers can communicate. A second purpose was to explore factors that might impact these rates, including the modeling influence of other drivers. A series of observations involving more than 5600 vehicles making turns were recorded at a variety of intersections in British Columbia, Canada. Though the occurrence of signal use varied widely, ranging from a low of 54% to a high of 95%, the overall rate was 76%. Drivers used turn signals significantly less often when making right as compared with left turns, when traffic volume was higher, and when a designated turning lane was provided. In addition, compared with drivers following another vehicle not using signals, those following a vehicle with turn signals on were significantly more likely to activate their turn signals, suggesting a possible modeling effect. Both internal and external influences on turn signal use by drivers were considered. External factors explored in this research included direction of turn, traffic volume, intersection configuration, and the example of other drivers. It was concluded that the practice of signaling turns merits more research attention, since consistent use of signals is a potential contributor to enhanced safety for all road users. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. The influence of metal-support interactions on the whiteline intensity

    NARCIS (Netherlands)

    Vaarkamp, M.; Miller, J.T.; Modica, F.S.; Koningsberger, D.C.; Kuroda, H.; Ohta, T.

    1993-01-01

    The whiteline intensity of Pt/K-LTL catalysts reduced at 300, 450, and 600 Deg decreases with increasing redn. temp. This change in whiteline intensity was ascribed to the removal of hydrogen from the metal-support interface by redn. at higher temp.

  12. Laser Induced Breakdown Spectroscopy Based on Single Beam Splitting and Geometric Configuration for Effective Signal Enhancement

    Science.gov (United States)

    Yang, Guang; Lin, Qingyu; Ding, Yu; Tian, Di; Duan, Yixiang

    2015-01-01

    A new laser induced breakdown spectroscopy (LIBS) based on single-beam-splitting (SBS) and proper optical geometric configuration has been initially explored in this work for effective signal enhancement. In order to improve the interaction efficiency of laser energy with the ablated material, a laser beam operated in pulse mode was divided into two streams to ablate/excite the target sample in different directions instead of the conventional one beam excitation in single pulse LIBS (SP-LIBS). In spatial configuration, the laser beam geometry plays an important role in the emission signal enhancement. Thus, an adjustable geometric configuration with variable incident angle between the two splitted laser beams was constructed for achieving maximum signal enhancement. With the optimized angles of 60° and 70° for Al and Cu atomic emission lines at 396.15 nm and 324.75 nm respectively, about 5.6- and 4.8-folds signal enhancements were achieved for aluminum alloy and copper alloy samples compared to SP-LIBS. Furthermore, the temporal analysis, in which the intensity of atomic lines in SP-LIBS decayed at least ten times faster than the SBS-LIBS, proved that the energy coupling efficiency of SBS-LIBS was significantly higher than that of SP-LIBS. PMID:25557721

  13. Hypoxia induces a phase transition within a kinase signaling network in cancer cells

    Science.gov (United States)

    Wei, Wei; Shi, Qihui; Remacle, Francoise; Qin, Lidong; Shackelford, David B.; Shin, Young Shik; Mischel, Paul S.; Levine, R. D.; Heath, James R.

    2013-01-01

    Hypoxia is a near-universal feature of cancer, promoting glycolysis, cellular proliferation, and angiogenesis. The molecular mechanisms of hypoxic signaling have been intensively studied, but the impact of changes in oxygen partial pressure (pO2) on the state of signaling networks is less clear. In a glioblastoma multiforme (GBM) cancer cell model, we examined the response of signaling networks to targeted pathway inhibition between 21% and 1% pO2. We used a microchip technology that facilitates quantification of a panel of functional proteins from statistical numbers of single cells. We find that near 1.5% pO2, the signaling network associated with mammalian target of rapamycin (mTOR) complex 1 (mTORC1)—a critical component of hypoxic signaling and a compelling cancer drug target—is deregulated in a manner such that it will be unresponsive to mTOR kinase inhibitors near 1.5% pO2, but will respond at higher or lower pO2 values. These predictions were validated through experiments on bulk GBM cell line cultures and on neurosphere cultures of a human-origin GBM xenograft tumor. We attempt to understand this behavior through the use of a quantitative version of Le Chatelier’s principle, as well as through a steady-state kinetic model of protein interactions, both of which indicate that hypoxia can influence mTORC1 signaling as a switch. The Le Chatelier approach also indicates that this switch may be thought of as a type of phase transition. Our analysis indicates that certain biologically complex cell behaviors may be understood using fundamental, thermodynamics-motivated principles. PMID:23530221

  14. Hypoxia induces a phase transition within a kinase signaling network in cancer cells.

    Science.gov (United States)

    Wei, Wei; Shi, Qihui; Remacle, Francoise; Qin, Lidong; Shackelford, David B; Shin, Young Shik; Mischel, Paul S; Levine, R D; Heath, James R

    2013-04-09

    Hypoxia is a near-universal feature of cancer, promoting glycolysis, cellular proliferation, and angiogenesis. The molecular mechanisms of hypoxic signaling have been intensively studied, but the impact of changes in oxygen partial pressure (pO2) on the state of signaling networks is less clear. In a glioblastoma multiforme (GBM) cancer cell model, we examined the response of signaling networks to targeted pathway inhibition between 21% and 1% pO2. We used a microchip technology that facilitates quantification of a panel of functional proteins from statistical numbers of single cells. We find that near 1.5% pO2, the signaling network associated with mammalian target of rapamycin (mTOR) complex 1 (mTORC1)--a critical component of hypoxic signaling and a compelling cancer drug target--is deregulated in a manner such that it will be unresponsive to mTOR kinase inhibitors near 1.5% pO2, but will respond at higher or lower pO2 values. These predictions were validated through experiments on bulk GBM cell line cultures and on neurosphere cultures of a human-origin GBM xenograft tumor. We attempt to understand this behavior through the use of a quantitative version of Le Chatelier's principle, as well as through a steady-state kinetic model of protein interactions, both of which indicate that hypoxia can influence mTORC1 signaling as a switch. The Le Chatelier approach also indicates that this switch may be thought of as a type of phase transition. Our analysis indicates that certain biologically complex cell behaviors may be understood using fundamental, thermodynamics-motivated principles.

  15. ESR signal features of 60Co γ-ray irradiated bone tissue and its dose response relationship

    International Nuclear Information System (INIS)

    Wu Ke; Sun Zunpu; Shi Yuanming

    1993-01-01

    Electron spin resonance (ESR) technique was used to study the radiation-induced ESR signal features of different paramagnetic species of 60 Co γ-ray irradiated bone tissue. The results showed that the intensity of an ESR signal at that the intensity of an ESR signal at g 2.0022 of human bones exposed to a dose range of 0-50 Gy had linear dose response relationships. The lower limit of detectable dose was about 2 Gy and the detecting error was about 10%. The signal was stable at room temperature during 60 days, and the effect of radiation dose rate of 0.5-8.0 Gy/min could be neglected. This signal was insensitive to microwave power and temperature, which was suitable for rapid and direct detection with ESR technique. These features suggest that human bones could be used for radiation accident dose evaluation by ESR

  16. Effects of caffeine on neuromuscular fatigue and performance during high-intensity cycling exercise in moderate hypoxia.

    Science.gov (United States)

    Smirmaul, Bruno P C; de Moraes, Antonio Carlos; Angius, Luca; Marcora, Samuele M

    2017-01-01

    To investigate the effects of caffeine on performance, neuromuscular fatigue and perception of effort during high-intensity cycling exercise in moderate hypoxia. Seven adult male participants firstly underwent an incremental exercise test on a cycle ergometer in conditions of acute normobaric hypoxia (fraction inspired oxygen = 0.15) to establish peak power output (PPO). In the following two visits, they performed a time to exhaustion test (78 ± 3% PPO) in the same hypoxic conditions after caffeine ingestion (4 mg kg -1 ) and one after placebo ingestion in a double-blind, randomized, counterbalanced cross-over design. Caffeine significantly improved time to exhaustion by 12%. A significant decrease in subjective fatigue was found after caffeine consumption. Perception of effort and surface electromyographic signal amplitude of the vastus lateralis were lower and heart rate was higher in the caffeine condition when compared to placebo. However, caffeine did not reduce the peripheral and central fatigue induced by high-intensity cycling exercise in moderate hypoxia. The caffeine-induced improvement in time to exhaustion during high-intensity cycling exercise in moderate hypoxia seems to be mediated by a reduction in perception of effort, which occurs despite no reduction in neuromuscular fatigue.

  17. The dynamics of color signals in male threespine sticklebacks Gasterosteus aculeatus.

    Science.gov (United States)

    Hiermes, Meike; Rick, Ingolf P; Mehlis, Marion; Bakker, Theo C M

    2016-02-01

    Body coloration and color patterns are ubiquitous throughout the animal kingdom and vary between and within species. Recent studies have dealt with individual dynamics of various aspects of coloration, as it is in many cases a flexible trait and changes in color expression may be context-dependent. During the reproductive phase, temporal changes of coloration in the visible spectral range (400-700 nm) have been shown for many animals but corresponding changes in the ultraviolet (UV) waveband (300-400 nm) have rarely been studied. Threespine stickleback Gasterosteus aculeatus males develop conspicuous orange-red breeding coloration combined with UV reflectance in the cheek region. We investigated dynamics of color patterns including UV throughout a male breeding cycle, as well as short-term changes in coloration in response to a computer-animated rival using reflectance spectrophotometry and visual modeling, to estimate how colors would be perceived by conspecifics. We found the orange-red component of coloration to vary during the breeding cycle with respect to hue ( theta /R50) and intensity (achieved chroma/red chroma). Furthermore, color intensity in the orange-red spectral part (achieved chroma) tended to be increased after the presentation of an artificial rival. Dynamic changes in specific measures of hue and intensity in the UV waveband were not found. In general, the orange-red component of the signal seems to be dynamic with respect to color intensity and hue. This accounts in particular for color changes during the breeding cycle, presumably to signal reproductive status, and with limitations as well in the intrasexual context, most likely to signal dominance or inferiority.

  18. Capacity Bounds and High-SNR Capacity of MIMO Intensity-Modulation Optical Channels

    KAUST Repository

    Chaaban, Anas

    2018-02-19

    The capacity of the intensity modulation direct detection multiple-input multiple-output channel is studied. Therein, the nonnegativity constraint of the transmit signal limits the applicability of classical schemes, including precoding. Thus, new ways are required for deriving capacity bounds for this channel. To this end, capacity lower bounds are developed in this paper by deriving the achievable rates of two precodingfree schemes: Channel inversion and QR decomposition. The achievable rate of a DC-offset SVD-based scheme is also derived as a benchmark. Then, capacity upper bounds are derived and compared against the lower bounds. As a result, the capacity at high signal-to-noise ratio (SNR) is characterized for the case where the number of transmit apertures is not larger than the number of receive apertures, and is shown to be achievable by the QR decomposition scheme. This is shown for a channel with average intensity or peak intensity constraints. Under both constraints, the high-SNR capacity is approximated within a small gap. Extensions to a channel with more transmit apertures than receive apertures are discussed, and capacity bounds for this case are derived.

  19. Capacity Bounds and High-SNR Capacity of MIMO Intensity-Modulation Optical Channels

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2018-01-01

    The capacity of the intensity modulation direct detection multiple-input multiple-output channel is studied. Therein, the nonnegativity constraint of the transmit signal limits the applicability of classical schemes, including precoding. Thus, new ways are required for deriving capacity bounds for this channel. To this end, capacity lower bounds are developed in this paper by deriving the achievable rates of two precodingfree schemes: Channel inversion and QR decomposition. The achievable rate of a DC-offset SVD-based scheme is also derived as a benchmark. Then, capacity upper bounds are derived and compared against the lower bounds. As a result, the capacity at high signal-to-noise ratio (SNR) is characterized for the case where the number of transmit apertures is not larger than the number of receive apertures, and is shown to be achievable by the QR decomposition scheme. This is shown for a channel with average intensity or peak intensity constraints. Under both constraints, the high-SNR capacity is approximated within a small gap. Extensions to a channel with more transmit apertures than receive apertures are discussed, and capacity bounds for this case are derived.

  20. Validation of the Amsterdam Dynamic Facial Expression Set--Bath Intensity Variations (ADFES-BIV: A Set of Videos Expressing Low, Intermediate, and High Intensity Emotions.

    Directory of Open Access Journals (Sweden)

    Tanja S H Wingenbach

    Full Text Available Most of the existing sets of facial expressions of emotion contain static photographs. While increasing demand for stimuli with enhanced ecological validity in facial emotion recognition research has led to the development of video stimuli, these typically involve full-blown (apex expressions. However, variations of intensity in emotional facial expressions occur in real life social interactions, with low intensity expressions of emotions frequently occurring. The current study therefore developed and validated a set of video stimuli portraying three levels of intensity of emotional expressions, from low to high intensity. The videos were adapted from the Amsterdam Dynamic Facial Expression Set (ADFES and termed the Bath Intensity Variations (ADFES-BIV. A healthy sample of 92 people recruited from the University of Bath community (41 male, 51 female completed a facial emotion recognition task including expressions of 6 basic emotions (anger, happiness, disgust, fear, surprise, sadness and 3 complex emotions (contempt, embarrassment, pride that were expressed at three different intensities of expression and neutral. Accuracy scores (raw and unbiased (Hu hit rates were calculated, as well as response times. Accuracy rates above chance level of responding were found for all emotion categories, producing an overall raw hit rate of 69% for the ADFES-BIV. The three intensity levels were validated as distinct categories, with higher accuracies and faster responses to high intensity expressions than intermediate intensity expressions, which had higher accuracies and faster responses than low intensity expressions. To further validate the intensities, a second study with standardised display times was conducted replicating this pattern. The ADFES-BIV has greater ecological validity than many other emotion stimulus sets and allows for versatile applications in emotion research. It can be retrieved free of charge for research purposes from the

  1. Validation of the Amsterdam Dynamic Facial Expression Set--Bath Intensity Variations (ADFES-BIV): A Set of Videos Expressing Low, Intermediate, and High Intensity Emotions.

    Science.gov (United States)

    Wingenbach, Tanja S H; Ashwin, Chris; Brosnan, Mark

    2016-01-01

    Most of the existing sets of facial expressions of emotion contain static photographs. While increasing demand for stimuli with enhanced ecological validity in facial emotion recognition research has led to the development of video stimuli, these typically involve full-blown (apex) expressions. However, variations of intensity in emotional facial expressions occur in real life social interactions, with low intensity expressions of emotions frequently occurring. The current study therefore developed and validated a set of video stimuli portraying three levels of intensity of emotional expressions, from low to high intensity. The videos were adapted from the Amsterdam Dynamic Facial Expression Set (ADFES) and termed the Bath Intensity Variations (ADFES-BIV). A healthy sample of 92 people recruited from the University of Bath community (41 male, 51 female) completed a facial emotion recognition task including expressions of 6 basic emotions (anger, happiness, disgust, fear, surprise, sadness) and 3 complex emotions (contempt, embarrassment, pride) that were expressed at three different intensities of expression and neutral. Accuracy scores (raw and unbiased (Hu) hit rates) were calculated, as well as response times. Accuracy rates above chance level of responding were found for all emotion categories, producing an overall raw hit rate of 69% for the ADFES-BIV. The three intensity levels were validated as distinct categories, with higher accuracies and faster responses to high intensity expressions than intermediate intensity expressions, which had higher accuracies and faster responses than low intensity expressions. To further validate the intensities, a second study with standardised display times was conducted replicating this pattern. The ADFES-BIV has greater ecological validity than many other emotion stimulus sets and allows for versatile applications in emotion research. It can be retrieved free of charge for research purposes from the corresponding author.

  2. Double-staining chromogenic in situ hybridization as a useful alternative to split-signal fluorescence in situ hybridization in lymphoma diagnostics

    DEFF Research Database (Denmark)

    van Rijk, A.; Svenstroup-Poulsen, T.; Jones, M.

    2010-01-01

    within the reach of every pathology laboratory. Design and Methods Our study was initiated to determine the consistency between chromogenic in situ hybridization and fluorescence in situ hybridization, both using split-signal probes developed for the detection of chromosomal breaks. Five hundred...... and actual signal were compared to the original fluorescence hybridization results. In addition, hematoxylin background staining intensity and signal intensity of the double-staining chromogenic in situ hybridization procedure were analyzed. Results With respect to the presence or absence of chromosomal...

  3. Time-Frequency Analysis of Signals Generated by Rotating Machines

    Directory of Open Access Journals (Sweden)

    R. Zetik

    1999-06-01

    Full Text Available This contribution is devoted to the higher order time-frequency analyses of signals. Firstly, time-frequency representations of higher order (TFRHO are defined. Then L-Wigner distribution (LWD is given as a special case of TFRHO. Basic properties of LWD are illustrated based on the analysis of mono-component and multi-component synthetic signals and acoustical signals generated by rotating machine. The obtained results confirm usefulness of LWD application for the purpose of rotating machine condition monitoring.

  4. Memories of social interactions: age differences in emotional intensity.

    Science.gov (United States)

    Charles, Susan Turk; Piazza, Jennifer R

    2007-06-01

    The current study examined age differences in the intensity of emotions experienced during social interactions. Because emotions are felt most intensely in situations central to motivational goals, age differences in emotional intensity may exist in social situations that meet the goals for one age group more than the other. Guided by theories of emotional intensity and socioemotional selectivity, it was hypothesized that social partner type would elicit different affective responses by age. Younger (n = 71) and older (n = 71) adults recalled experiences of positive and negative emotions with new friends, established friends, and family members from the prior week. Compared with younger adults, older adults reported lower intensity positive emotions with new friends, similarly intense positive emotions with established friends, and higher intensity positive emotions with family members. Older adults reported lower intensity negative emotions for all social partners than did younger adults, but this difference was most pronounced for interactions with new friends. ((c) 2007 APA, all rights reserved).

  5. Predictive value of T2 relative signal intensity for response to somatostatin analogs in newly diagnosed acromegaly

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Ming; Zhang, Qilin [Fudan University, Department of Neurosurgery, Huashan Hospital, Shanghai Medical College, Shanghai (China); Shanghai Pituitary Tumor Center, Shanghai (China); Liu, Wenjuan; Li, Yiming; Zhang, Zhaoyun; Ye, Hongying; He, Min; Lu, Bin; Yang, Yeping [Shanghai Pituitary Tumor Center, Shanghai (China); Fudan University, Department of Endocrinology and Metabolism, Huashan Hospital, Shanghai Medical College, Shanghai (China); Wang, Meng [Fudan University, Department of Endocrinology and Metabolism, Huashan Hospital, Shanghai Medical College, Shanghai (China); Soochow University, Division of Endocrinology, the Second Affiliated Hospital, Suzhou (China); Zhu, Jingjing [Shanghai Pituitary Tumor Center, Shanghai (China); Fudan University, Department of Neuropathology, Huashan Hospital, Shanghai Medical College, Shanghai (China); Ma, Zengyi; He, Wenqiang; Li, Shiqi; Shou, Xuefei; Qiao, Nidan; Ye, Zhao; Zhang, Yichao; Zhao, Yao; Wang, Yongfei [Fudan University, Department of Neurosurgery, Huashan Hospital, Shanghai Medical College, Shanghai (China); Shanghai Pituitary Tumor Center, Shanghai (China); Yao, Zhenwei [Shanghai Pituitary Tumor Center, Shanghai (China); Fudan University, Department of Radiology, Huashan Hospital, Shanghai Medical College, Shanghai (China); Lu, Yun [Fudan University, Department of Nuclear Medicine, Huashan Hospital, Shanghai Medical College, Shanghai (China)

    2016-11-15

    The difficulty of predicting the efficacy of somatostatin analogs (SSA) is not fully resolved. Here, we quantitatively evaluated the predictive value of relative signal intensity (rSI) on T1- and T2-weighted magnetic resonance imaging (MRI) for the short-term efficacy (3 months) of SSA therapy in patients with active acromegaly and assessed the correlation between MRI rSI and expression of somatostatin receptors (SSTR). This was a retrospective review of prospectively recorded data. Ninety-two newly diagnosed patients (37 males and 55 females) with active acromegaly were recruited. All patients were treated with pre-surgical SSA, followed by reassessment and transspenoidal surgery. rSI values were generated by calculating the ratio of SI in the tumor to the SI of normal frontal white matter. The Youden indices were calculated to determine the optimal cutoff of rSI to determine the efficacy of SSA. The correlation between rSI and expression of SSTR2/5 was analyzed by the Spearman rank correlation coefficient. T2 rSI was strongly correlated with biochemical sensitivity to SSA. The cutoff value of T2 rSI to distinguish biochemical sensitivity was 1.205, with a positive predictive value (PPV) of 81.5 % and a negative predictive value (NPV) of 77.3 %. No correlation was found between MRI and tumor size sensitivity. Moreover, T2 rSI was negatively correlated with the expression of SSTR5. T2 rSI correlates with the expression of SSTR5 and quantitatively predicts the biochemical efficacy of SSA in acromegaly. (orig.)

  6. Predictive value of T2 relative signal intensity for response to somatostatin analogs in newly diagnosed acromegaly

    International Nuclear Information System (INIS)

    Shen, Ming; Zhang, Qilin; Liu, Wenjuan; Li, Yiming; Zhang, Zhaoyun; Ye, Hongying; He, Min; Lu, Bin; Yang, Yeping; Wang, Meng; Zhu, Jingjing; Ma, Zengyi; He, Wenqiang; Li, Shiqi; Shou, Xuefei; Qiao, Nidan; Ye, Zhao; Zhang, Yichao; Zhao, Yao; Wang, Yongfei; Yao, Zhenwei; Lu, Yun

    2016-01-01

    The difficulty of predicting the efficacy of somatostatin analogs (SSA) is not fully resolved. Here, we quantitatively evaluated the predictive value of relative signal intensity (rSI) on T1- and T2-weighted magnetic resonance imaging (MRI) for the short-term efficacy (3 months) of SSA therapy in patients with active acromegaly and assessed the correlation between MRI rSI and expression of somatostatin receptors (SSTR). This was a retrospective review of prospectively recorded data. Ninety-two newly diagnosed patients (37 males and 55 females) with active acromegaly were recruited. All patients were treated with pre-surgical SSA, followed by reassessment and transspenoidal surgery. rSI values were generated by calculating the ratio of SI in the tumor to the SI of normal frontal white matter. The Youden indices were calculated to determine the optimal cutoff of rSI to determine the efficacy of SSA. The correlation between rSI and expression of SSTR2/5 was analyzed by the Spearman rank correlation coefficient. T2 rSI was strongly correlated with biochemical sensitivity to SSA. The cutoff value of T2 rSI to distinguish biochemical sensitivity was 1.205, with a positive predictive value (PPV) of 81.5 % and a negative predictive value (NPV) of 77.3 %. No correlation was found between MRI and tumor size sensitivity. Moreover, T2 rSI was negatively correlated with the expression of SSTR5. T2 rSI correlates with the expression of SSTR5 and quantitatively predicts the biochemical efficacy of SSA in acromegaly. (orig.)

  7. Predictive value of T2 relative signal intensity for response to somatostatin analogs in newly diagnosed acromegaly.

    Science.gov (United States)

    Shen, Ming; Zhang, Qilin; Liu, Wenjuan; Wang, Meng; Zhu, Jingjing; Ma, Zengyi; He, Wenqiang; Li, Shiqi; Shou, Xuefei; Li, Yiming; Zhang, Zhaoyun; Ye, Hongying; He, Min; Lu, Bin; Yao, Zhenwei; Lu, Yun; Qiao, Nidan; Ye, Zhao; Zhang, Yichao; Yang, Yeping; Zhao, Yao; Wang, Yongfei

    2016-11-01

    The difficulty of predicting the efficacy of somatostatin analogs (SSA) is not fully resolved. Here, we quantitatively evaluated the predictive value of relative signal intensity (rSI) on T1- and T2-weighted magnetic resonance imaging (MRI) for the short-term efficacy (3 months) of SSA therapy in patients with active acromegaly and assessed the correlation between MRI rSI and expression of somatostatin receptors (SSTR). This was a retrospective review of prospectively recorded data. Ninety-two newly diagnosed patients (37 males and 55 females) with active acromegaly were recruited. All patients were treated with pre-surgical SSA, followed by reassessment and transspenoidal surgery. rSI values were generated by calculating the ratio of SI in the tumor to the SI of normal frontal white matter. The Youden indices were calculated to determine the optimal cutoff of rSI to determine the efficacy of SSA. The correlation between rSI and expression of SSTR2/5 was analyzed by the Spearman rank correlation coefficient. T2 rSI was strongly correlated with biochemical sensitivity to SSA. The cutoff value of T2 rSI to distinguish biochemical sensitivity was 1.205, with a positive predictive value (PPV) of 81.5 % and a negative predictive value (NPV) of 77.3 %. No correlation was found between MRI and tumor size sensitivity. Moreover, T2 rSI was negatively correlated with the expression of SSTR5. T2 rSI correlates with the expression of SSTR5 and quantitatively predicts the biochemical efficacy of SSA in acromegaly.

  8. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals

    Directory of Open Access Journals (Sweden)

    Jiping Xiong

    2017-03-01

    Full Text Available Although wrist-type photoplethysmographic (hereafter referred to as WPPG sensor signals can measure heart rate quite conveniently, the subjects’ hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  9. Intermuscular Coherence Between Surface EMG Signals Is Higher for Monopolar Compared to Bipolar Electrode Configurations

    Directory of Open Access Journals (Sweden)

    Maurice Mohr

    2018-05-01

    Full Text Available Introduction: The vasti muscles have to work in concert to control knee joint motion during movements like walking, running, or squatting. Coherence analysis between surface electromyography (EMG signals is a common technique to study muscle synchronization during such movements and gain insight into strategies of the central nervous system to optimize neuromuscular performance. However, different assessment methods related to EMG data acquisition, e.g., different electrode configurations or amplifier technologies, have produced inconsistent observations. Therefore, the aim of this study was to elucidate the effect of different EMG acquisition techniques (monopolar vs. bipolar electrode configuration, potential vs. current amplifier on the magnitude, reliability, and sensitivity of intermuscular coherence between two vasti muscles during stable and unstable squatting exercises.Methods: Surface EMG signals from vastus lateralis (VL and medialis (VM were obtained from eighteen adults while performing series of stable und unstable bipedal squats. The EMG signals were acquired using three different recording techniques: (1 Bipolar with a potential amplifier, (2 monopolar with a potential amplifier, and (3 monopolar electrodes with a current amplifier. VL-VM coherence between the respective raw EMG signals was determined during two trials of stable squatting and one trial of unstable squatting to compare the coherence magnitude, reliability, and sensitivity between EMG recording techniques.Results: VL-VM coherence was about twice as high for monopolar recordings compared to bipolar recordings for all squatting exercises while coherence was similar between monopolar potential and current recordings. Reliability measures were comparable between recording systems while the sensitivity to an increase in intermuscular coherence during unstable vs. stable squatting was lowest for the monopolar potential system.Discussion and Conclusion: The choice of

  10. SignalSpider: Probabilistic pattern discovery on multiple normalized ChIP-Seq signal profiles

    KAUST Repository

    Wong, Kachun

    2014-09-05

    Motivation: Chromatin immunoprecipitation (ChIP) followed by high-throughput sequencing (ChIP-Seq) measures the genome-wide occupancy of transcription factors in vivo. Different combinations of DNA-binding protein occupancies may result in a gene being expressed in different tissues or at different developmental stages. To fully understand the functions of genes, it is essential to develop probabilistic models on multiple ChIP-Seq profiles to decipher the combinatorial regulatory mechanisms by multiple transcription factors. Results: In this work, we describe a probabilistic model (SignalSpider) to decipher the combinatorial binding events of multiple transcription factors. Comparing with similar existing methods, we found SignalSpider performs better in clustering promoter and enhancer regions. Notably, SignalSpider can learn higher-order combinatorial patterns from multiple ChIP-Seq profiles. We have applied SignalSpider on the normalized ChIP-Seq profiles from the ENCODE consortium and learned model instances. We observed different higher-order enrichment and depletion patterns across sets of proteins. Those clustering patterns are supported by Gene Ontology (GO) enrichment, evolutionary conservation and chromatin interaction enrichment, offering biological insights for further focused studies. We also proposed a specific enrichment map visualization method to reveal the genome-wide transcription factor combinatorial patterns from the models built, which extend our existing fine-scale knowledge on gene regulation to a genome-wide level. Availability and implementation: The matrix-algebra-optimized executables and source codes are available at the authors\\' websites: http://www.cs.toronto.edu/∼wkc/SignalSpider. Contact: Supplementary information: Supplementary data are available at Bioinformatics online.

  11. The AD and ELENA orbit, trajectory and intensity measurement systems

    Science.gov (United States)

    Marco-Hernández, R.; Alves, D.; Angoletta, M. E.; Marqversen, O.; Molendijk, J.; Oponowicz, E.; Ruffieux, R.; Sánchez-Quesada, J.; SØby, L.

    2017-07-01

    This paper describes the new Antiproton Decelerator (AD) orbit measurement system and the Extra Low ENergy Antiproton ring (ELENA) orbit, trajectory and intensity measurement system. The AD machine at European Organization for Nuclear Research (CERN) is presently being used to decelerate antiprotons from 3.57 GeV/c to 100 MeV/c for matter vs anti-matter comparative studies. The ELENA machine, presently under commissioning, has been designed to provide an extra deceleration stage down to 13.7 MeV/c. The AD orbit system is based on 32 horizontal and 27 vertical electrostatic Beam Position Monitor (BPM) fitted with existing low noise front-end amplifiers while the ELENA system consists of 24 \\gls{BPM}s equipped with new low-noise head amplifiers. In both systems the front-end amplifiers generate a difference (delta) and a sum (sigma) signal which are sent to the digital acquisition system, placed tens of meters away from the AD or ELENA rings, where they are digitized and further processed. The beam position is calculated by dividing the difference signal by the sum signal either using directly the raw digitized data for measuring the turn-by-turn trajectory in the ELENA system or after down-mixing the signals to baseband for the orbit measurement in both machines. The digitized sigma signal will be used in the ELENA system to calculate the bunched beam intensity and the Schottky parameters with coasting beam after passing through different signal processing chain. The digital acquisition arrangement for both systems is based on the same hardware, also used in the ELENA Low Level Radio Frequency (LLRF) system, which follows the VME Switched Serial (VXS) enhancement of the Versa Module Eurocard 64x extension (VME64x) standard and includes VITA 57 standard Field Programmable Gate Array Mezzanine Card (FMC). The digital acquisition Field Programmable Gate Array (FPGA) and Digital Signal Processor (DSP) firmware shares many common functionalities with the LLRF system but

  12. MR imaging of diffuse thyroid disorders

    International Nuclear Information System (INIS)

    Inoue, Masaaki; Fujii, Koichi; Ohnishi, Takuya; Higashikawa, Motoki; Araki, Yutaka; Hamada, Tatsumi; Ishida, Osamu

    1996-01-01

    Magnetic resonance imaging was performed in 38 diffuse goiters, including 30 chronic thyroiditis and 8 Basedow disease. MR findings were analyzed as to degree of swelling, margin, internal structures including homogeneity and low intensity bands. With regard to signal intensity, thyroid-muscle-signal intensity ratios on T1 and T2-weighted images were measured in 19 normal thyroid glands, 30 chronic thyroiditis and 8 Basedow disease. Additionally thyroid-muscle-signal intensity ratios were compared between 19 hypothyroid glands and 11 euthyroid glands in chronic thyroiditis. Chronic thyroiditis tended to show lobulated margins, inhomogeneous intensity, and low intensity bands connecting with vessels or not. Basedow disease tended to display smooth margins, inhomogeneous intensity and low intensity bands connecting with vessels. Thyroid-muscle-signal intensity ratios of Basedow disease and chronic thyroiditis were significantly higher than those of normal thyroid gland at all sequences. In chronic thyroiditis thyroid-muscle-signal intensity ratios of euthyroid glands were significantly higher than those of hypothyroid glands. MR imaging could reflect pathologic features of diffuse goiters. Moreover, MR imaging is potentially contributory to speculate about thyroid function and degree of serious condition in diffuse thyroid disorders. (author)

  13. Neurotrophin Signaling via Long-Distance Axonal Transport

    Science.gov (United States)

    Chowdary, Praveen D.; Che, Dung L.; Cui, Bianxiao

    2012-05-01

    Neurotrophins are a family of target-derived growth factors that support survival, development, and maintenance of innervating neurons. Owing to the unique architecture of neurons, neurotrophins that act locally on the axonal terminals must convey their signals across the entire axon for subsequent regulation of gene transcription in the cell nucleus. This long-distance retrograde signaling, a motor-driven process that can take hours or days, has been a subject of intense interest. In the last decade, live-cell imaging with high sensitivity has significantly increased our capability to track the transport of neurotrophins, their receptors, and subsequent signals in real time. This review summarizes recent research progress in understanding neurotrophin-receptor interactions at the axonal terminal and their transport dynamics along the axon. We emphasize high-resolution studies at the single-molecule level and also discuss recent technical advances in the field.

  14. Realization of rapid debugging for detection circuit of optical fiber gas sensor: Using an analog signal source

    Science.gov (United States)

    Tian, Changbin; Chang, Jun; Wang, Qiang; Wei, Wei; Zhu, Cunguang

    2015-03-01

    An optical fiber gas sensor mainly consists of two parts: optical part and detection circuit. In the debugging for the detection circuit, the optical part usually serves as a signal source. However, in the debugging condition, the optical part can be easily influenced by many factors, such as the fluctuation of ambient temperature or driving current resulting in instability of the wavelength and intensity for the laser; for dual-beam sensor, the different bends and stresses of the optical fiber will lead to the fluctuation of the intensity and phase; the intensity noise from the collimator, coupler, and other optical devices in the system will also result in the impurity of the optical part based signal source. In order to dramatically improve the debugging efficiency of the detection circuit and shorten the period of research and development, this paper describes an analog signal source, consisting of a single chip microcomputer (SCM), an amplifier circuit, and a voltage-to-current conversion circuit. It can be used to realize the rapid debugging detection circuit of the optical fiber gas sensor instead of optical part based signal source. This analog signal source performs well with many other advantages, such as the simple operation, small size, and light weight.

  15. Validation of the Amsterdam Dynamic Facial Expression Set – Bath Intensity Variations (ADFES-BIV): A Set of Videos Expressing Low, Intermediate, and High Intensity Emotions

    Science.gov (United States)

    Wingenbach, Tanja S. H.

    2016-01-01

    Most of the existing sets of facial expressions of emotion contain static photographs. While increasing demand for stimuli with enhanced ecological validity in facial emotion recognition research has led to the development of video stimuli, these typically involve full-blown (apex) expressions. However, variations of intensity in emotional facial expressions occur in real life social interactions, with low intensity expressions of emotions frequently occurring. The current study therefore developed and validated a set of video stimuli portraying three levels of intensity of emotional expressions, from low to high intensity. The videos were adapted from the Amsterdam Dynamic Facial Expression Set (ADFES) and termed the Bath Intensity Variations (ADFES-BIV). A healthy sample of 92 people recruited from the University of Bath community (41 male, 51 female) completed a facial emotion recognition task including expressions of 6 basic emotions (anger, happiness, disgust, fear, surprise, sadness) and 3 complex emotions (contempt, embarrassment, pride) that were expressed at three different intensities of expression and neutral. Accuracy scores (raw and unbiased (Hu) hit rates) were calculated, as well as response times. Accuracy rates above chance level of responding were found for all emotion categories, producing an overall raw hit rate of 69% for the ADFES-BIV. The three intensity levels were validated as distinct categories, with higher accuracies and faster responses to high intensity expressions than intermediate intensity expressions, which had higher accuracies and faster responses than low intensity expressions. To further validate the intensities, a second study with standardised display times was conducted replicating this pattern. The ADFES-BIV has greater ecological validity than many other emotion stimulus sets and allows for versatile applications in emotion research. It can be retrieved free of charge for research purposes from the corresponding author

  16. A photodiode amplifier system for pulse-by-pulse intensity measurement of an x-ray free electron laser.

    Science.gov (United States)

    Kudo, Togo; Tono, Kensuke; Yabashi, Makina; Togashi, Tadashi; Sato, Takahiro; Inubushi, Yuichi; Omodani, Motohiko; Kirihara, Yoichi; Matsushita, Tomohiro; Kobayashi, Kazuo; Yamaga, Mitsuhiro; Uchiyama, Sadayuki; Hatsui, Takaki

    2012-04-01

    We have developed a single-shot intensity-measurement system using a silicon positive-intrinsic-negative (PIN) photodiode for x-ray pulses from an x-ray free electron laser. A wide dynamic range (10(3)-10(11) photons/pulse) and long distance signal transmission (>100 m) were required for this measurement system. For this purpose, we developed charge-sensitive and shaping amplifiers, which can process charge pulses with a wide dynamic range and variable durations (ns-μs) and charge levels (pC-μC). Output signals from the amplifiers were transmitted to a data acquisition system through a long cable in the form of a differential signal. The x-ray pulse intensities were calculated from the peak values of the signals by a waveform fitting procedure. This system can measure 10(3)-10(9) photons/pulse of ~10 keV x-rays by direct irradiation of a silicon PIN photodiode, and from 10(7)-10(11) photons/pulse by detecting the x-rays scattered by a diamond film using the silicon PIN photodiode. This system gives a relative accuracy of ~10(-3) with a proper gain setting of the amplifiers for each measurement. Using this system, we succeeded in detecting weak light at the developmental phase of the light source, as well as intense light during lasing of the x-ray free electron laser. © 2012 American Institute of Physics

  17. Proton energy dependence of slow neutron intensity

    International Nuclear Information System (INIS)

    Teshigawara, Makoto; Harada, Masahide; Watanabe, Noboru; Kai, Tetsuya; Sakata, Hideaki; Ikeda, Yujiro

    2001-01-01

    The choice of the proton energy is an important issue for the design of an intense-pulsed-spallation source. The optimal proton beam energy is rather unique from a viewpoint of the leakage neutron intensity but no yet clear from the slow-neutron intensity view point. It also depends on an accelerator type. Since it is also important to know the proton energy dependence of slow-neutrons from the moderators in a realistic target-moderator-reflector assembly (TMRA). We studied on the TMRA proposed for Japan Spallation Neutron Source. The slow-neutron intensities from the moderators per unit proton beam power (MW) exhibit the maximum at about 1-2 GeV. At higher proton energies the intensity per MW goes down; at 3 and 50 GeV about 0.91 and 0.47 times as low as that at 1 GeV. The proton energy dependence of slow-neutron intensities was found to be almost the same as that of total neutron yield (leakage neutrons) from the same bare target. It was also found that proton energy dependence was almost the same for the coupled and decoupled moderators, regardless the different moderator type, geometry and coupling scheme. (author)

  18. A low power biomedical signal processor ASIC based on hardware software codesign.

    Science.gov (United States)

    Nie, Z D; Wang, L; Chen, W G; Zhang, T; Zhang, Y T

    2009-01-01

    A low power biomedical digital signal processor ASIC based on hardware and software codesign methodology was presented in this paper. The codesign methodology was used to achieve higher system performance and design flexibility. The hardware implementation included a low power 32bit RISC CPU ARM7TDMI, a low power AHB-compatible bus, and a scalable digital co-processor that was optimized for low power Fast Fourier Transform (FFT) calculations. The co-processor could be scaled for 8-point, 16-point and 32-point FFTs, taking approximate 50, 100 and 150 clock circles, respectively. The complete design was intensively simulated using ARM DSM model and was emulated by ARM Versatile platform, before conducted to silicon. The multi-million-gate ASIC was fabricated using SMIC 0.18 microm mixed-signal CMOS 1P6M technology. The die area measures 5,000 microm x 2,350 microm. The power consumption was approximately 3.6 mW at 1.8 V power supply and 1 MHz clock rate. The power consumption for FFT calculations was less than 1.5 % comparing with the conventional embedded software-based solution.

  19. Intensity-based readout of resonant-waveguide grating biosensors: Systems and nanostructures

    Science.gov (United States)

    Paulsen, Moritz; Jahns, Sabrina; Gerken, Martina

    2017-09-01

    Resonant waveguide gratings (RWG) - also called photonic crystal slabs (PCS) - have been established as reliable optical transducers for label-free biochemical assays as well as for cell-based assays. Current readout systems are based on mechanical scanning and spectrometric measurements with system sizes suitable for laboratory equipment. Here, we review recent progress in compact intensity-based readout systems for point-of-care (POC) applications. We briefly introduce PCSs as sensitive optical transducers and introduce different approaches for intensity-based readout systems. Photometric measurements have been realized with a simple combination of a light source and a photodetector. Recently a 96-channel, intensity-based readout system for both biochemical interaction analyses as well as cellular assays was presented employing the intensity change of a near cut-off mode. As an alternative for multiparametric detection, a camera system for imaging detection has been implemented. A portable, camera-based system of size 13 cm × 4.9 cm × 3.5 cm with six detection areas on an RWG surface area of 11 mm × 7 mm has been demonstrated for the parallel detection of six protein binding kinetics. The signal-to-noise ratio of this system corresponds to a limit of detection of 168 M (24 ng/ml). To further improve the signal-to-noise ratio advanced nanostructure designs are investigated for RWGs. Here, results on multiperiodic and deterministic aperiodic nanostructures are presented. These advanced nanostructures allow for the design of the number and wavelengths of the RWG resonances. In the context of intensity-based readout systems they are particularly interesting for the realization of multi-LED systems. These recent trends suggest that compact point-of-care systems employing disposable test chips with RWG functional areas may reach market in the near future.

  20. Beam intensity scanner system for three dimensional dose verification of IMRT

    International Nuclear Information System (INIS)

    Vahc, Young W.; Kwon, Ohyun; Park, Kwangyl; Park, Kyung R.; Yi, Byung Y.; Kim, Keun M.

    2003-01-01

    Patient dose verification is clinically one of the most important parts in the treatment delivery of radiation therapy. The three dimensional (3D) reconstruction of dose distribution delivered to target volume helps to verify patient dose and determine the physical characteristics of beams used in IMRT. Here we present beam intensity scanner (BInS) system for the pre-treatment dosimetric verification of two dimensional photon intensity. The BInS is a radiation detector with a custom-made software for dose conversion of fluorescence signals from scintillator. The scintillator is used to produce fluorescence from the irradiation of 6 MV photons on a Varian Clinac 21EX. The digitized fluoroscopic signals obtained by digital video camera-based scintillator (DVCS) will be processed by our custom made software to reproduce 3D- relative dose distribution. For the intensity modulated beam (IMB), the BInS calculates absorbed dose in absolute beam fluence which is used for the patient dose distribution. Using BInS, we performed various measurements related to IMRT and found the following: (1) The 3D-dose profiles of the IMBs measured by the BInS demonstrate good agreement with radiographic film, pin type ionization chamber and Monte Carlo simulation. (2) The delivered beam intensity is altered by the mechanical and dosimetric properties of the collimation of dynamic and/or step MLC system. This is mostly due to leaf transmission, leaf penumbra scattered photons from the round edges of leaves, and geometry of leaf. (3) The delivered dose depends on the operational detail of how to make multi leaf opening. These phenomena result in a fluence distribution that can be substantially different from the initial and calculated intensity modulation and therefore, should be taken into account by the treatment planning for accurate dose calculations delivered to the target volume in IMRT. (author)

  1. Integrating patterning signals: Wnt/GSK3 regulates the duration of the BMP/Smad1 signal.

    Science.gov (United States)

    Fuentealba, Luis C; Eivers, Edward; Ikeda, Atsushi; Hurtado, Cecilia; Kuroda, Hiroki; Pera, Edgar M; De Robertis, Edward M

    2007-11-30

    BMP receptors determine the intensity of BMP signals via Smad1 C-terminal phosphorylations. Here we show that a finely controlled cell biological pathway terminates this activity. The duration of the activated pSmad1(Cter) signal was regulated by sequential Smad1 linker region phosphorylations at conserved MAPK and GSK3 sites required for its polyubiquitinylation and transport to the centrosome. Proteasomal degradation of activated Smad1 and total polyubiquitinated proteins took place in the centrosome. Inhibitors of the Erk, p38, and JNK MAPKs, as well as GSK3 inhibitors, prolonged the duration of a pulse of BMP7. Wnt signaling decreased pSmad1(GSK3) antigen levels and redistributed it from the centrosome to cytoplasmic LRP6 signalosomes. In Xenopus embryos, it was found that Wnts induce epidermis and that this required an active BMP-Smad pathway. Epistatic experiments suggested that the dorsoventral (BMP) and anteroposterior (Wnt/GSK3) patterning gradients are integrated at the level of Smad1 phosphorylations during embryonic pattern formation.

  2. Wild western lowland gorillas signal selectively using odor.

    Directory of Open Access Journals (Sweden)

    Michelle Klailova

    Full Text Available Mammals communicate socially through visual, auditory and chemical signals. The chemical sense is the oldest sense and is shared by all organisms including bacteria. Despite mounting evidence for social chemo-signaling in humans, the extent to which it modulates behavior is debated and can benefit from comparative models of closely related hominoids. The use of odor cues in wild ape social communication has been only rarely explored. Apart from one study on wild chimpanzee sniffing, our understanding is limited to anecdotes. We present the first study of wild gorilla chemo-communication and the first analysis of olfactory signaling in relation to arousal levels and odor strength in wild apes. If gorilla scent is used as a signaling mechanism instead of only a sign of arousal or stress, odor emission should be context specific and capable of variation as a function of the relationships between the emitter and perceiver(s. Measured through a human pungency scale, we determined the factors that predicted extreme levels of silverback odor for one wild western lowland gorilla (Gorilla gorilla gorilla group silverback. Extreme silverback odor was predicted by the presence and intensity of inter-unit interactions, silverback anger, distress and long-calling auditory rates, and the absence of close proximity between the silverback and mother of the youngest infant. Odor strength also varied according to the focal silverback's strategic responses during high intensity inter-unit interactions. Silverbacks appear to use odor as a modifiable form of communication; where odor acts as a highly flexible, context dependent signaling mechanism to group members and extra-group units. The importance of olfaction to ape social communication may be especially pertinent in Central African forests where limited visibility may necessitate increased reliance on other senses.

  3. REVIEW ARTICLE: Bioluminescent signals and the role of reflectors

    Science.gov (United States)

    Herring, Peter J.

    2000-11-01

    Organisms in a well lit environment use optical signals derived from the selective reflection of ambient light. In a dim or dark environment it is very difficult (because of low photon numbers) to detect the contrast between light reflected from the organism and that from the background, and many organisms use bioluminescent signals instead. The use of such signals on land is largely restricted to sexual signalling by the luminous beetles, but in the deep ocean their use is widespread, involving both many different organisms and a range of uses which parallel those of reflective signals on land. Some bioluminescent signals rely almost entirely on an optically unmodified light source (e.g. a secretion) but others depend upon complex optical structures, particularly reflectors, in the light-emitting organs. Reflectors in the light organs of many shrimp, squid and fish are based on constructive interference systems but employ different biological materials. They and other structures modify the angular, spectral and intensity distributions of bioluminescent signals. The ready availability of highly efficient biological reflectors has been a formative influence in the evolution of bioluminescent signalling in the sea.

  4. All-optical microwave signal processing based on optical phase modulation

    Science.gov (United States)

    Zeng, Fei

    This thesis presents a theoretical and experimental study of optical phase modulation and its applications in all-optical microwave signal processing, which include all-optical microwave filtering, all-optical microwave mixing, optical code-division multiple-access (CDMA) coding, and ultrawideband (UWB) signal generation. All-optical microwave signal processing can be considered as the use of opto-electronic devices and systems to process microwave signals in the optical domain, which provides several significant advantages such as low loss, low dispersion, light weight, high time bandwidth products, and immunity to electromagnetic interference. In conventional approaches, the intensity of an optical carrier is modulated by a microwave signal based on direct modulation or external modulation. The intensity-modulated optical signal is then fed to a photonic circuit or system to achieve specific signal processing functionalities. The microwave signal being processed is usually obtained based on direct detection, i.e., an opto-electronic conversion by use of a photodiode. In this thesis, the research efforts are focused on the optical phase modulation and its applications in all-optical microwave signal processing. To avoid using coherent detection which is complicated and costly, simple and effective phase modulation to intensity modulation (PM-IM) conversion schemes are pursued. Based on a theoretical study of optical phase modulation, two approaches to achieving PM-IM conversions are proposed. In the first approach, the use of chromatic dispersion induced by a dispersive device to alter the phase relationships among the sidebands and the optical carrier of a phase-modulated optical signal to realize PM-IM conversion is investigated. In the second approach, instead of using a dispersive device, the PM-IM conversion is realized based on optical frequency discrimination implemented using an optical filter. We show that the proposed PM-IM conversion schemes can be

  5. Study of interhemispheric asymmetries in electroencephalographic signals by frequency analysis

    International Nuclear Information System (INIS)

    Zapata, J F; Garzon, J

    2011-01-01

    This study provides a new method for the detection of interhemispheric asymmetries in patients with continuous video-electroencephalography (EEG) monitoring at Intensive Care Unit (ICU), using wavelet energy. We obtained the registration of EEG signals in 42 patients with different pathologies, and then we proceeded to perform signal processing using the Matlab program, we compared the abnormalities recorded in the report by the neurophysiologist, the images of each patient and the result of signals analysis with the Discrete Wavelet Transform (DWT). Conclusions: there exists correspondence between the abnormalities found in the processing of the signal with the clinical reports of findings in patients; according to previous conclusion, the methodology used can be a useful tool for diagnosis and early quantitative detection of interhemispheric asymmetries.

  6. Comparison of in situ ionizing radiation effects on Raman and photoluminescence intensity of high OH, low OH silica, and fluoride core fibers

    Science.gov (United States)

    Bilodeau, T. G.; Ewing, K. J.; Nau, G. M.; Aggarwal, I. D.

    1995-06-01

    An in situ study of the effects of ionizing radiation on the strength of the Raman and photoluminescence signal of high OH, low OH, and fluoride core fibers has been performed with 514.5 nm laser excitation. The fibers were irradiated with a 60Co source at a constant dose rate of 560 rads/h. The high OH fiber displayed a much slower decay of the fiber Raman intensity than the other two fibers during irradiation. The fluoride fiber exhibited the quickest decline in Raman signal with the intensity dropping by a factor of 1000 in less than 20 min. The Raman intensity of the low OH silica fiber recovered to greater than 90% of its pre-irradiation value after a post-irradiation photoanneal with 488 nm laser light. The silica fibers displayed an increase in intensity of a broad photoluminescence feature centered at 650 nm. However the fiber photoluminescence intensity remained much weaker than the Raman intensity throughout the irradiations.

  7. Informal workshop on intense polarized ion sources: a summary

    International Nuclear Information System (INIS)

    Schultz, P.F.

    1980-01-01

    An Informal Workshop on Intense Polarized Ion Sources was held on March 6, 1980, at the O'Hare Hilton Hotel, Chicago, Illinois. The purpose of the Workshop was to discuss problems in developing higher-intensity polarized proton sources, particularly the optically-pumped source recently proposed by L.W. Anderson of the University of Wisconsin. A summary of the discussions is reported

  8. Cost-effectiveness of Intensive Blood Pressure Management

    DEFF Research Database (Denmark)

    Richman, Ilana B; Fairley, Michael; Jørgensen, Mads Emil

    2016-01-01

    Importance: Among high-risk patients with hypertension, targeting a systolic blood pressure of 120 mm Hg reduces cardiovascular morbidity and mortality compared with a higher target. However, intensive blood pressure management incurs additional costs from treatment and from adverse events......-effectiveness of intensive blood pressure management among 68-year-old high-risk adults with hypertension but not diabetes. We used the Systolic Blood Pressure Intervention Trial (SPRINT) to estimate treatment effects and adverse event rates. We used Centers for Disease Control and Prevention Life Tables to project age...... and accrued $155 261 in lifetime costs, while intensive management yielded 10.5 QALYs and accrued $176 584 in costs. Intensive blood pressure management cost $23 777 per QALY gained. In a sensitivity analysis, serious adverse events would need to occur at 3 times the rate observed in SPRINT and be 3 times...

  9. Within-session responses to high-intensity interval training in spinal cord injury.

    Science.gov (United States)

    Astorino, Todd Anthony; Thum, Jacob S

    2018-02-01

    Completion of high-intensity interval training (HIIT) increases maximal oxygen uptake and health status, yet its feasibility in persons with spinal cord injury is unknown. To compare changes in cardiorespiratory and metabolic variables between two interval training regimes and moderate intensity exercise. Nine adults with spinal cord injury (duration = 6.8 ± 6.2 year) initially underwent determination of peak oxygen uptake. During subsequent sessions, they completed moderate intensity exercise, HIIT, or sprint interval training. Oxygen uptake, heart rate, and blood lactate concentration were measured. Oxygen uptake and heart rate increased (p  0.05) to moderate intensity exercise. Peak oxygen uptake and heart rate were higher (p HIIT (90% peak oxygen uptake and 99% peak heart rate) and sprint interval training (80% peak oxygen uptake and 96% peak heart rate) versus moderate intensity exercise. Despite a higher intensity and peak cardiorespiratory strain, all participants preferred interval training versus moderate exercise. Examining long-term efficacy and feasibility of interval training in this population is merited, considering that exercise intensity is recognized as the most important variable factor of exercise programming to optimize maximal oxygen uptake. Implications for Rehabilitation Spinal cord injury (SCI) reduces locomotion which impairs voluntary physical activity, typically resulting in a reduction in peak oxygen uptake and enhanced chronic disease risk. In various able-bodied populations, completion of high-intensity interval training (HIIT) has been consistently reported to improve cardiorespiratory fitness and other health-related outcomes, although its efficacy in persons with SCI is poorly understood. Data from this study in 9 men and women with SCI show similar changes in oxygen uptake and heart in response to HIIT compared to a prolonged bout of aerobic exercise, although peak values were higher in response to HIIT. Due to

  10. Effects of iodinated contrast agent, xylocaine and gadolinium concentration on the signal emitted in magnetic resonance arthrography: a samples study

    Directory of Open Access Journals (Sweden)

    Yvana Lopes Pinheiro da Silva

    2015-04-01

    Full Text Available Objective: To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality. Materials and Methods: Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration. Results: As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions. Conclusion: Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography.

  11. SELECTIVE ACTIVATION OF THE RECTUS ABDOMINIS MUSCLE DURING LOW-INTENSITY AND FATIGUING TASKS

    Directory of Open Access Journals (Sweden)

    Paulo H. Marchetti

    2011-06-01

    Full Text Available In order to understand the potential selective activation of the rectus abdominis muscle, we conducted two experiments. In the first, subjects performed two controlled isometric exercises: the curl up (supine trunk raise and the leg raise (supine bent leg raise at low intensity (in which only a few motor units are recruited. In the second experiment, subjects performed the same exercises, but they were required to maintain a certain force level in order to induce fatigue. We recorded the electromyographic (EMG activities of the lower and upper portions of the rectus abdominis muscle during the exercises and used spatial-temporal and frequency analyses to describe muscle activation patterns. At low-intensity contractions, the ratio between the EMG intensities of the upper and lower portions during the curl up exercise was significantly larger than during the leg raise exercise (p = 0.02. A cross-correlation analysis indicated that the signals of the abdominal portions were related to each other and this relation did not differ between the tasks (p = 0.12. In the fatiguing condition, fatigue for the upper portion was higher than for the lower portion during the curl up exercise (p = 0.008. We conclude that different exercises evoked, to a certain degree, individualized activation of each part of the rectus abdominis muscle, but different portions of the rectus abdominis muscle contributed to the same task, acting like a functional unit. These results corroborate the relevance of varying exercise to modify activation patterns of the rectus abdominis muscle

  12. Generation and coherent detection of QPSK signal using a novel method of digital signal processing

    Science.gov (United States)

    Zhao, Yuan; Hu, Bingliang; He, Zhen-An; Xie, Wenjia; Gao, Xiaohui

    2018-02-01

    We demonstrate an optical quadrature phase-shift keying (QPSK) signal transmitter and an optical receiver for demodulating optical QPSK signal with homodyne detection and digital signal processing (DSP). DSP on the homodyne detection scheme is employed without locking the phase of the local oscillator (LO). In this paper, we present an extracting one-dimensional array of down-sampling method for reducing unwanted samples of constellation diagram measurement. Such a novel scheme embodies the following major advantages over the other conventional optical QPSK signal detection methods. First, this homodyne detection scheme does not need strict requirement on LO in comparison with linear optical sampling, such as having a flat spectral density and phase over the spectral support of the source under test. Second, the LabVIEW software is directly used for recovering the QPSK signal constellation without employing complex DSP circuit. Third, this scheme is applicable to multilevel modulation formats such as M-ary PSK and quadrature amplitude modulation (QAM) or higher speed signals by making minor changes.

  13. Quantitative evaluation of high intensity signal on MIP images of carotid atherosclerotic plaques from routine TOF-MRA reveals elevated volumes of intraplaque hemorrhage and lipid rich necrotic core.

    Science.gov (United States)

    Yamada, Kiyofumi; Song, Yan; Hippe, Daniel S; Sun, Jie; Dong, Li; Xu, Dongxiang; Ferguson, Marina S; Chu, Baocheng; Hatsukami, Thomas S; Chen, Min; Zhou, Cheng; Yuan, Chun

    2012-11-29

    Carotid intraplaque hemorrhage (IPH) and lipid rich necrotic core (LRNC) have been associated with accelerated plaque growth, luminal narrowing, future surface disruption and development of symptomatic events. The aim of this study was to evaluate the quantitative relationships between high intensity signals (HIS) in the plaque on TOF-MRA and IPH or LRNC volumes as measured by multicontrast weighted CMR. Seventy six patients with a suspected carotid artery stenosis or carotid plaque by ultrasonography underwent multicontrast carotid CMR. HIS presence and volume were measured from TOF-MRA MIP images while IPH and LRNC volumes were separately measured from multicontrast CMR. For detecting IPH, HIS on MIP images overall had high specificity (100.0%, 95% CI: 93.0 - 100.0%) but relatively low sensitivity (32%, 95% CI: 20.8 - 47.9%). However, the sensitivity had a significant increasing relationship with underlying IPH volume (p = 0.033) and degree of stenosis (p = 0.022). Mean IPH volume was 2.7 times larger in those with presence of HIS than in those without (142.8 ± 97.7 mm(3) vs. 53.4 ± 56.3 mm(3), p = 0.014). Similarly, mean LRNC volume was 3.4 times larger in those with HIS present (379.8 ± 203.4 mm(3) vs. 111.3 ± 122.7 mm(3), p = 0.001). There was a strong correlation between the volume of the HIS region and the IPH volume measured from multicontrast CMR (r = 0.96, p routine, clinical TOF sequences. High intensity signals in carotid plaque on TOF-MRA MIP images are associated with increased intraplaque hemorrhage and lipid-rich necrotic core volumes. The technique is most sensitive in patients with moderate to severe stenosis.

  14. Signal grass structure at different sites of the same pasture under three grazing intensities - doi: 10.4025/actascianimsci.v35i1.11801

    Directory of Open Access Journals (Sweden)

    Ronan Lopes Albino

    2013-01-01

    Full Text Available The experiment was conducted to evaluate Brachiaria decumbens cv. Basilisk at different sites of the same pasture featuring varying grazing intensities (under grazed, properly grazed and overgrazed. The pasture was managed under continuous stocking using 200-kg cattle and grass height kept at about 25 cm. The randomized block design was used, with three replications. Sward height (38.0 cm and extended plant height (85.2 cm were greater at the under grazed site. The falling index was lower at the properly grazed site (1.28. At the under grazed site, the masses of green leaf blade (3442 kg ha-1 DM, green stem (8370 kg ha-1 DM, green forage (11812 kg ha-1 DM and total forage (14137 kg ha-1 DM were higher when compared to the overgrazed and properly grazed sites. Dead material mass was higher at the properly grazed (3422 kg ha-1 DM and under grazed (2324 kg ha-1 DM sites. At the under grazed sites, there was a higher occurrence of tillers taller than 40 cm. Tillers with sizes between 10 and 30 cm predominated in properly grazed sites. In overgrazed site there was a higher share of tillers with sizes smaller than 20 cm. There is spatial variability of vegetation in the same pasture of Brachiaria decumbens cv. Basilisk due to uneven grazing by cattle.

  15. Selective attention and the auditory vertex potential. 2: Effects of signal intensity and masking noise

    Science.gov (United States)

    Schwent, V. L.; Hillyard, S. A.; Galambos, R.

    1975-01-01

    A randomized sequence of tone bursts was delivered to subjects at short inter-stimulus intervals with the tones originating from one of three spatially and frequency specific channels. The subject's task was to count the tones in one of the three channels at a time, ignoring the other two, and press a button after each tenth tone. In different conditions, tones were given at high and low intensities and with or without a background white noise to mask the tones. The N sub 1 component of the auditory vertex potential was found to be larger in response to attended channel tones in relation to unattended tones. This selective enhancement of N sub 1 was minimal for loud tones presented without noise and increased markedly for the lower tone intensity and in noise added conditions.

  16. Olfactory memories are intensity specific in larval Drosophila.

    Science.gov (United States)

    Mishra, Dushyant; Chen, Yi-Chun; Yarali, Ayse; Oguz, Tuba; Gerber, Bertram

    2013-05-01

    Learning can rely on stimulus quality, stimulus intensity, or a combination of these. Regarding olfaction, the coding of odour quality is often proposed to be combinatorial along the olfactory pathway, and working hypotheses are available concerning short-term associative memory trace formation of odour quality. However, it is less clear how odour intensity is coded, and whether olfactory memory traces include information about the intensity of the learnt odour. Using odour-sugar associative conditioning in larval Drosophila, we first describe the dose-effect curves of learnability across odour intensities for four different odours (n-amyl acetate, 3-octanol, 1-octen-3-ol and benzaldehyde). We then chose odour intensities such that larvae were trained at an intermediate odour intensity, but were tested for retention with either that trained intermediate odour intensity, or with respectively higher or lower intensities. We observed a specificity of retention for the trained intensity for all four odours used. This adds to the appreciation of the richness in 'content' of olfactory short-term memory traces, even in a system as simple as larval Drosophila, and to define the demands on computational models of associative olfactory memory trace formation. We suggest two kinds of circuit architecture that have the potential to accommodate intensity learning, and discuss how they may be implemented in the insect brain.

  17. Increased signal intensity of prostate lesions on high b-value diffusion-weighted images as a predictive sign of malignancy

    International Nuclear Information System (INIS)

    Quentin, Michael; Schimmoeller, Lars; Antoch, Gerald; Blondin, Dirk; Arsov, Christian; Rabenalt, Robert; Albers, Peter

    2014-01-01

    The evaluation of lesions detected in prostate magnetic resonance imaging (MRI) with increased signal intensity (SI) on high b-value diffusion-weighted images as a sign of malignancy. One hundred and three consecutive patients with prostate MRI examination and MRI-guided in-bore biopsy were retrospectively included in the study. MRI-guided in-bore biopsy histologically confirmed prostate cancer in 50 patients (n = 92 lesions). The other 53 patients (n = 122 lesions) had negative bioptical results. In patients with histologically confirmed prostate cancer, 46 of the 92 lesions had visually increased SI on the high b-value images compared with the peripheral zone (SI = +27 ± 16%) or the central gland (SI = +37 ± 19%, P < 0.001 respectively). In patients with a negative biopsy, ten of the 122 lesions had visually increased SI (compared with the peripheral zone, SI = +29 ± 18%, and with the central gland, SI = +41 ± 15%, P < 0.001 respectively). Neither the apparent diffusion coefficient (ADC) values nor the Gleason Score of lesions with increased SI were significantly different from lesions without increased SI. Visually increased SI on the high b-value images of diffusion-weighted imaging using standard b-values is a sign of malignancy but can occasionally also be a feature of benign lesions. However, it does not indicate more aggressive tumours. (orig.)

  18. Troubleshooting of signal power supply system for Shanghai metro line 7

    Science.gov (United States)

    Lu, Kaixia; Xiao, Jie

    2018-03-01

    With the rapid development of Urban Rail Transit Signal Technology, the demand of signal power supply system for signal equipment is higher and higher. The signal intelligent power supply panel is the main component of the urban rail traffic signal power supply system. Whether the intelligent power supply panel working or not is directly related to traffic safety. The maintenance of intelligent signal power supply panel is particularly important. Line 7 of Shanghai Metro adopts PMZG Signal Intelligent Power Supply Panel, which is produced by Beijing Jinyujiaxin Polytron Technologies Inc. Maintenance of power supply system mainly includes routine maintenance and troubleshooting. This article will make clear the routine maintenance contents of PMZG Signal Intelligent Power Supply Panel, and put forward the common fault information and troubleshooting methods of PMZG Signal Intelligent Power Supply Panel. In accordance with the steps of fault handling, the faults can be eliminated in the shortest possible time, and PMZG Signal Intelligent Power Supply Panel can be quickly restored to normal working state.

  19. Characteristic signal changes in the pontine base on T2- and multishot diffusion-weighted images in spinocerebellar ataxia type 1

    International Nuclear Information System (INIS)

    Adachi, M.; Kawanami, T.; Ohshima, H.; Hosoya, T.

    2006-01-01

    The aim of the present study was to demonstrate characteristic signal changes of the pontine base on T2-weighted images of patients with SCA 1, and to elucidate the relationship between abnormal high-intensities of the pontine base on T2-weighted images and the findings on multishot diffusion-weighted images. We assessed abnormal signals of the pontine base on T2-weighted images from 50 controls and six patients with SCA 1 diagnosed by genetic analysis. At the same time, we evaluated the degeneration of the transverse pontine fibers in the pontine base by multishot diffusion-weighted imaging. A midline high-intensity was seen in the pontine base on T2-weighted images in two of the 50 controls and five of the six patients with SCA 1. The midline high-intensity had a sensitivity of 83.3% for patients and a specificity of 96.0% for controls. Multishot diffusion-weighted imaging demonstrated the degeneration - the amorphous-pattern signal - of the transverse pontine fibers in four (66.7%) of the six patients. In the other two patients, the zebra-pattern signal was seen in the pontine base. The midline high-intensity on T2-weighted images appears to be one of characteristic MRI findings of SCA 1. Multishot diffusion-weighted imaging suggested that the midline high-intensity should reflect the degeneration of the transverse pontine fibers. (orig.)

  20. Scenarios of future energy intensities

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    In this chapter, the authors present scenarios of potential change in energy intensities in the OECD countries and in the Soviet Union. These scenarios are meant to illustrate how intensities might evolve over the next 20 years given different conditions with respect to energy prices, energy-efficiency policies, and other key factors. Changes in intensity will also be affected by the rates of growth and stock turnover in each sector. They have not tried to forecast how activity levels and structure will evolve. However, the OECD scenarios assume a world in which GDP averages growth in the 2-3%/year range, with some differences among countries. For the Soviet Union, the degree and pace of intensity decline will be highly dependent on the success of the transition to a market economy; each scenario explicitly envisions a different degree of success. They have not constructed comparable scenarios for the developing countries. The scenarios presented in this chapter do not predict what will happen in the future. They believe, however, that they illustrate a plausible set of outcomes if energy prices, policies, programs, and other factors evolve as described in each case. With higher energy prices and vigorous policies and programs, intensities in the OECD countries in 2010 could be nearly 50% less on average than the level where trends seem to be point. In the former Soviet Union, a combination of rapid, successful economic reform and extra effort to improve energy efficiency might result in average intensity being nearly 40% less than in a slow reform case. And in the LDCs, a mixture of sound policies, programs, and energy pricing reform could also lead to intensities being far lower than they would be otherwise. 8 refs., 10 figs., 1 tab

  1. Energy intensities: Prospects and potential

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    In the previous chapter, the author described how rising activity levels and structural change are pushing toward higher energy use in many sectors and regions, especially in the developing countries. The extent to which more activity leads to greater energy use will depend on the energy intensity of end-use activities. In this chapter, the author presents an overview of the potential for intensity reductions in each sector over the next 10-20 years. It is not the author's intent to describe in detail the various technologies that could be employed to improve energy efficiency, which has been done by others (see, for example, Lovins ampersand Lovins, 1991; Goldembert et al., 1987). Rather, he discusses the key factors that will shape future energy intensities in different parts of the world, and gives a sense for the changes that could be attained if greater attention were given to accelerate efficiency improvement. The prospects for energy intensities, and the potential for reduction, vary among sectors and parts of the world. In the majority of cases, intensities are tending to decline as new equipment and facilities come into use and improvements are made on existing stocks. The effect of stock turnover will be especially strong in the developing countries, where stocks are growing at a rapid pace, and the Former East Bloc, where much of the existing industrial plant will eventually be retired and replaced with more modern facilities. While reductions in energy intensity are likely in most areas, there is a large divergence between the technical and economic potential for reducing energy intensities and the direction in which present trends are moving. In the next chapter, the author presents scenarios that illustrate where trends are pointing, and what could be achieved if improving energy efficiency were a focus of public policies. 53 refs., 4 figs., 2 tabs

  2. Finite-mode analysis by means of intensity information in fractional optical systems

    NARCIS (Netherlands)

    Alieva, T.; Bastiaans, M.J.

    2002-01-01

    It is shown how a coherent optical signal that contains only a finite number of Hermite-Gauss modes, can be reconstructed from the knowledge of its Radon-Wigner transform -- associated with the intensity distribution in a fractional Fourier transform optical system -- at only two transversal points.

  3. Growth performance, carcass yield and gait score of Marshal broiler chicken reared on intensive and semi intensive management systems

    Directory of Open Access Journals (Sweden)

    Oluwadiya, B. O.

    2017-06-01

    Full Text Available The rearing system used in highly productive farms is often subjected to harsh criticism, one of the reasons being its failure to provide adequate welfare. A number of attempts have been made to introduce new technologies in rearing poultry for meat production aiming at improving rearing conditions, protecting the environment and enhancing the quality of poultry products. Given the above, one hundred and sixty eight unsexed 14-day old Marshall broiler chicks were used in a completely randomized design study to compare the effect of management systems (intensive and semi intensive on the growth performance, carcass characteristics and gait score of broiler chickens. The experiment lasted for 42 d. Data were collected on weight gain, feed intake, feed conversion ratio, carcass yield and gait score. Result showed that birds on the intensive management system recorded higher weight gain (P 0.05; 66.94%, 11.44% than those in semi-intensive system (54.55%, 10.92%, respectively. For the gait score broiler birds on semi intensive management system recorded reduced number of cases of severe and slight leg problems (P < 0.05, 25.76% vs 49.3%. It was concluded that broiler birds should be reared on intensive management system for better growth performance and carcass yield. However, birds reared on semi intensive management system had fewer leg problems compared to birds reared on intensive management system. The fewer severe leg problems observed in birds on semi intensive management system will help improve their market value thereby making birds more profitable to rear on semi intensive management system.

  4. High Intensity Interval Training for Maximizing Health Outcomes.

    Science.gov (United States)

    Karlsen, Trine; Aamot, Inger-Lise; Haykowsky, Mark; Rognmo, Øivind

    Regular physical activity and exercise training are important actions to improve cardiorespiratory fitness and maintain health throughout life. There is solid evidence that exercise is an effective preventative strategy against at least 25 medical conditions, including cardiovascular disease, stroke, hypertension, colon and breast cancer, and type 2 diabetes. Traditionally, endurance exercise training (ET) to improve health related outcomes has consisted of low- to moderate ET intensity. However, a growing body of evidence suggests that higher exercise intensities may be superior to moderate intensity for maximizing health outcomes. The primary objective of this review is to discuss how aerobic high-intensity interval training (HIIT) as compared to moderate continuous training may maximize outcomes, and to provide practical advices for successful clinical and home-based HIIT. Copyright © 2017. Published by Elsevier Inc.

  5. Emergy-based comparative analysis of energy intensity in different industrial systems.

    Science.gov (United States)

    Liu, Zhe; Geng, Yong; Wang, Hui; Sun, Lu; Ma, Zhixiao; Tian, Xu; Yu, Xiaoman

    2015-12-01

    With the rapid economic development, energy consumption of China has been the second place in the world next to the USA. Usually, measuring energy consumption intensity or efficiency applies heat unit which is joule per gross domestic production (GDP) or coal equivalent per GDP. However, this measuring approach is only oriented by the conversion coefficient of heat combustion which does not match the real value of the materials during their formation in the ecological system. This study applied emergy analysis to evaluate the energy consumption intensity to fill this gap. Emergy analysis is considered as a bridge between ecological system and economic system, which can evaluate the contribution of ecological products and services as well as the load placed on environmental systems. In this study, emergy indicator for performing energy consumption intensity of primary energy was proposed. Industrial production is assumed as the main contributor of energy consumption compared to primary and tertiary industries. Therefore, this study validated this method by investigating the two industrial case studies which were Dalian Economic Development Area (DEDA) and Fuzhou economic and technological area (FETA), to comparatively study on their energy consumption intensity between the different kinds of industrial systems and investigate the reasons behind the differences. The results show that primary energy consumption (PEC) of DEDA was much higher than that of FETA during 2006 to 2010 and its primary energy consumption ratio (PECR) to total emergy involvement had a dramatically decline from year 2006 to 2010. In the same time, nonrenewable energy of PEC in DEDA was also much higher than that in FETA. The reason was that industrial structure of DEDA was mainly formed by heavy industries like petro-chemistry industry, manufacturing industries, and high energy-intensive industries. However, FETA was formed by electronic business, food industry, and light industries. Although

  6. Relativistic electron mirrors from high intensity laser nanofoil interactions

    International Nuclear Information System (INIS)

    Kiefer, Daniel

    2012-01-01

    The reflection of a laser pulse from a mirror moving close to the speed of light could in principle create an X-ray pulse with unprecedented high brightness owing to the increase in photon energy and accompanying temporal compression by a factor of 4γ 2 , where γ is the Lorentz factor of the mirror. While this scheme is theoretically intriguingly simple and was first discussed by A. Einstein more than a century ago, the generation of a relativistic structure which acts as a mirror is demanding in many different aspects. Recently, the interaction of a high intensity laser pulse with a nanometer thin foil has raised great interest as it promises the creation of a dense, attosecond short, relativistic electron bunch capable of forming a mirror structure that scatters counter-propagating light coherently and shifts its frequency to higher photon energies. However, so far, this novel concept has been discussed only in theoretical studies using highly idealized interaction parameters. This thesis investigates the generation of a relativistic electron mirror from a nanometer foil with current state-of-the-art high intensity laser pulses and demonstrates for the first time the reflection from those structures in an experiment. To achieve this result, the electron acceleration from high intensity laser nanometer foil interactions was studied in a series of experiments using three inherently different high power laser systems and free-standing foils as thin as 3nm. A drastic increase in the electron energies was observed when reducing the target thickness from the micrometer to the nanometer scale. Quasi-monoenergetic electron beams were measured for the first time from ultrathin (≤5nm) foils, reaching energies up to ∝35MeV. The acceleration process was studied in simulations well-adapted to the experiments, indicating the transition from plasma to free electron dynamics as the target thickness is reduced to the few nanometer range. The experience gained from those

  7. A SIGNAL ENHANCED PORTABLE RAMAN PROBE FOR ANESTHETIC GAS MONITORING

    Directory of Open Access Journals (Sweden)

    S. Schlüter

    2015-03-01

    Full Text Available The spontaneous Raman scattering technique is an excellent tool for a quantitative analysis of multi-species gas mixtures. It is a noninvasive optical method for species identification and gas phase concentration measurement of all Raman active molecules, since the intensity of the species specific Raman signal is linearly dependent on the concentration. Applying a continuous wave (CW laser it typically takes a few seconds to capture a gas phase Raman spectrum at room temperature. Nevertheless in contrast to these advantages the weak Raman signal intensity is a major drawback. Thus, it is still challenging to detect gas phase Raman spectra in alow-pressure regime with a temporal resolution of only a few 100 ms. In this work a fully functional gas phase Raman system for measurements in the low-pressure regime (p ≥ 980 hPa (absolute is presented. It overcomes the drawback of a weak Raman signal by using a multipass cavity. A description of the sensor setup and of the multipass arrangement will be presented. Moreover the complete functionality of the sensor system will be demonstrated by measurements at an anesthesia simulator under clinical relevant conditions and in comparison to a conventional gas monitor.

  8. Preliminary study on electron paramagnetic resonance (EPR) signal properties of mobile phone components for dose estimation in radiation accident

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byeong Ryong; Ha, Wi Ho; Park, Sun Hoo; Lee, Jin Kyeong; Lee, Seung Sook [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2015-12-15

    We have investigated the EPR signal properties in 12 components of two mobile phones (LCD, OLED) using electron paramagnetic resonance (EPR) spectrometer in this study.EPR measurements were performed at normal atmospheric conditions using Bruker EXEXSYS-II E500 spectrometer with X-band bridge, and samples were irradiated by {sup 137}C{sub s} gamma-ray source. To identify the presence of radiation-induced signal (RIS), the EPR spectra of each sample were measured unirradiated and irradiated at 50 Gy. Then, dose-response curve and signal intensity variating by time after irradiation were measured. As a result, the signal intensity increased after irradiation in all samples except the USIM plastic and IC chip. Among the samples, cover glass(CG), lens, light guide plate(LGP) and diffusion sheet have shown fine linearity (R{sup 2} > 0.99). Especially, the LGP had ideal characteristics for dosimetry because there were no signal in 0 Gy and high rate of increase in RIS. However, this sample showed weakness in fading. Signal intensity of LGP and Diffusion Sheet decreased by 50% within 72 hours after irradiation, while signals of Cover Glass and Lens were stably preserved during the short period of time. In order to apply rapidly EPR dosimetry using mobile phone components in large-scale radiation accidents, further studies on signal differences for same components of the different mobile phone, fading, pretreatment of samples and processing of background signal are needed. However, it will be possible to do dosimetry by dose-additive method or comparative method using unirradiated same product in small-scale accident.

  9. Phase noise mitigation of QPSK signal utilizing phase-locked multiplexing of signal harmonics and amplitude saturation.

    Science.gov (United States)

    Mohajerin-Ariaei, Amirhossein; Ziyadi, Morteza; Chitgarha, Mohammad Reza; Almaiman, Ahmed; Cao, Yinwen; Shamee, Bishara; Yang, Jeng-Yuan; Akasaka, Youichi; Sekiya, Motoyoshi; Takasaka, Shigehiro; Sugizaki, Ryuichi; Touch, Joseph D; Tur, Moshe; Langrock, Carsten; Fejer, Martin M; Willner, Alan E

    2015-07-15

    We demonstrate an all-optical phase noise mitigation scheme based on the generation, delay, and coherent summation of higher order signal harmonics. The signal, its third-order harmonic, and their corresponding delayed variant conjugates create a staircase phase-transfer function that quantizes the phase of quadrature-phase-shift-keying (QPSK) signal to mitigate phase noise. The signal and the harmonics are automatically phase-locked multiplexed, avoiding the need for phase-based feedback loop and injection locking to maintain coherency. The residual phase noise converts to amplitude noise in the quantizer stage, which is suppressed by parametric amplification in the saturation regime. Phase noise reduction of ∼40% and OSNR-gain of ∼3  dB at BER 10(-3) are experimentally demonstrated for 20- and 30-Gbaud QPSK input signals.

  10. Prediction of chronic critical illness in a general intensive care unit

    Directory of Open Access Journals (Sweden)

    Sérgio H. Loss

    2013-06-01

    Full Text Available OBJECTIVE: To assess the incidence, costs, and mortality associated with chronic critical illness (CCI, and to identify clinical predictors of CCI in a general intensive care unit. METHODS: This was a prospective observational cohort study. All patients receiving supportive treatment for over 20 days were considered chronically critically ill and eligible for the study. After applying the exclusion criteria, 453 patients were analyzed. RESULTS: There was an 11% incidence of CCI. Total length of hospital stay, costs, and mortality were significantly higher among patients with CCI. Mechanical ventilation, sepsis, Glasgow score < 15, inadequate calorie intake, and higher body mass index were independent predictors for cci in the multivariate logistic regression model. CONCLUSIONS: CCI affects a distinctive population in intensive care units with higher mortality, costs, and prolonged hospitalization. Factors identifiable at the time of admission or during the first week in the intensive care unit can be used to predict CCI.

  11. Performance improvement of two-dimensional EUV spectroscopy based on high frame rate CCD and signal normalization method

    International Nuclear Information System (INIS)

    Zhang, H.M.; Morita, S.; Ohishi, T.; Goto, M.; Huang, X.L.

    2014-01-01

    In the Large Helical Device (LHD), the performance of two-dimensional (2-D) extreme ultraviolet (EUV) spectroscopy with wavelength range of 30-650A has been improved by installing a high frame rate CCD and applying a signal intensity normalization method. With upgraded 2-D space-resolved EUV spectrometer, measurement of 2-D impurity emission profiles with high horizontal resolution is possible in high-density NBI discharges. The variation in intensities of EUV emission among a few discharges is significantly reduced by normalizing the signal to the spectral intensity from EUV_—Long spectrometer which works as an impurity monitor with high-time resolution. As a result, high resolution 2-D intensity distribution has been obtained from CIV (384.176A), CV(2x40.27A), CVI(2x33.73A) and HeII(303.78A). (author)

  12. Measuring displacement signal with an accelerometer

    International Nuclear Information System (INIS)

    Han, Sang Bo

    2010-01-01

    An effective and simple way to reconstruct displacement signal from a measured acceleration signal is proposed in this paper. To reconstruct displacement signal by means of double-integrating the time domain acceleration signal, the Nyquist frequency of the digital sampling of the acceleration signal should be much higher than the highest frequency component of the signal. On the other hand, to reconstruct displacement signal by taking the inverse Fourier transform, the magnitude of the significant frequency components of the Fourier transform of the acceleration signal should be greater than the 6 dB increment line along the frequency axis. With a predetermined resolution in time and frequency domain, determined by the sampling rate to measure and record the original signal, reconstructing high-frequency signals in the time domain and reconstructing low-frequency signals in the frequency domain will produce biased errors. Furthermore, because of the DC components inevitably included in the sampling process, low-frequency components of the signals are overestimated when displacement signals are reconstructed from the Fourier transform of the acceleration signal. The proposed method utilizes curve-fitting around the significant frequency components of the Fourier transform of the acceleration signal before it is inverse-Fourier transformed. Curve-fitting around the dominant frequency components provides much better results than simply ignoring the insignificant frequency components of the signal

  13. Enhancing scatterometry CD signal-to-noise ratio for 1x logic and memory challenges

    Science.gov (United States)

    Shaughnessy, Derrick; Krishnan, Shankar; Wei, Lanhua; Shchegrov, Andrei V.

    2013-04-01

    The ongoing transition from 2D to 3D structures in logic and memory has led to an increased adoption of scatterometry CD (SCD) for inline metrology. However, shrinking device dimensions in logic and high aspect ratios in memory represent primary challenges for SCD and require a significant breakthrough in improving signal-to-noise performance. We present a report on the new generation of SCD technology, enabled by a new laser-driven plasma source. The developed light source provides several key advantages over conventional arc lamps typically used in SCD applications. The plasma color temperature of the laser driven source is considerably higher than available with arc lamps resulting in >5X increase in radiance in the visible and >10X increase in radiance in the DUV when compared to sources on previous generation SCD tools while maintaining or improving source intensity noise. This high radiance across such a broad spectrum allows for the use of a single light source from 190-1700nm. When combined with other optical design changes, the higher source radiance enables reduction of measurement box size of our spectroscopic ellipsometer from 45×45um box to 25×25um box without compromising signal to noise ratio. The benefits for 1×nm SCD metrology of the additional photons across the DUV to IR spectrum have been found to be greater than the increase in source signal to noise ratio would suggest. Better light penetration in Si and poly-Si has resulted in improved sensitivity and correlation breaking for critical parameters in 1xnm FinFET and HAR flash memory structures.

  14. High-Rate Strong-Signal Quantum Cryptography

    Science.gov (United States)

    Yuen, Horace P.

    1996-01-01

    Several quantum cryptosystems utilizing different kinds of nonclassical lights, which can accommodate high intensity fields and high data rate, are described. However, they are all sensitive to loss and both the high rate and the strong-signal character rapidly disappear. A squeezed light homodyne detection scheme is proposed which, with present-day technology, leads to more than two orders of magnitude data rate improvement over other current experimental systems for moderate loss.

  15. Effect of biological characteristics of different types of uterine fibroids, as assessed with T2-weighted magnetic resonance imaging, on ultrasound-guided high-intensity focused ultrasound ablation.

    Science.gov (United States)

    Zhao, Wen-Peng; Chen, Jin-Yun; Chen, Wen-Zhi

    2015-02-01

    The aims of this study were to assess the effects of the biological characteristics of different types of uterine fibroids, as assessed with T2-weighted magnetic resonance imaging (MRI), on ultrasound-guided high-intensity focused ultrasound (USgHIFU) ablation. Thirty-five patients with 39 symptomatic uterine fibroids who underwent myomectomy or hysterectomy were enrolled. Before surgery, the uterine fibroids were subdivided into hypo-intense, iso-intense, heterogeneous hyper-intense and homogeneous hyper-intense categories based on signal intensity on T2-weighted MRI. Tissue density and moisture content were determined in post-operative samples and normal uterine tissue, the isolated uterine fibroids were subjected to USgHIFU, and the extent of ablation was measured using triphenyltetrazolium chloride. Hematoxylin and eosin staining and sirius red staining were undertaken to investigate the organizational structure of the uterine fibroids. Estrogen and progesterone receptor expression was assayed via immunohistochemical staining. The mean diameter of uterine fibroids was 6.9 ± 2.8 cm. For all uterine fibroids, the average density and moisture content were 10.7 ± 0.7 mg/mL and 75.7 ± 2.4%, respectively; and for the homogeneous hyper-intense fibroids, 10.3 ± 0.5 mg/mL and 76.6 ± 2.3%. The latter subgroup had lower density and higher moisture content compared with the other subgroups. After USgHIFU treatment, the extent of ablation of the hyper-intense fibroids was 102.7 ± 42.1 mm(2), which was significantly less than those of the hypo-intense and heterogeneous hyper-intense fibroids. Hematoxylin and eosin staining and sirius red staining revealed that the homogeneous hyper-intense fibroids had sparse collagen fibers and abundant cells. Immunohistochemistry results revealed that estrogen and progesterone receptors were highly expressed in the homogeneous hyper-intense fibroids. This study revealed that lower density, higher moisture content, sparse collagen

  16. Wavelet transform for the evaluation of peak intensities in flow-injection analysis

    NARCIS (Netherlands)

    Bos, M.; Hoogendam, E.

    1992-01-01

    The application of the wavelet transform in the determination of peak intensities in flow-injection analysis was studied with regard to its properties of minimizing the effects of noise and baseline drift. The results indicate that for white noise and a favourable peak shape a signal-to-noise ratio

  17. Wavelett transform for the evaluation of peak intensities in flow-injection analysis

    NARCIS (Netherlands)

    Bos, M.; Hoogendam, E.; Hoogendam, E.

    1992-01-01

    The application of the wavelet transform in the determination of peak intensities in flow-injection analysis was studied with regard to its properties of minimizing the effects of noise and baseline drift. The results indicate that for white noise and a favourable peak shape a signal-to-noise ratio

  18. Extraversion and cardiovascular responses to recurrent social stress: Effect of stress intensity.

    Science.gov (United States)

    Lü, Wei; Xing, Wanying; Hughes, Brian M; Wang, Zhenhong

    2017-10-28

    The present study sought to establish whether the effects of extraversion on cardiovascular responses to recurrent social stress are contingent on stress intensity. A 2×5×1 mixed-factorial experiment was conducted, with social stress intensity as a between-subject variable, study phase as a within-subject variable, extraversion as a continuous independent variable, and cardiovascular parameter (HR, SBP, DBP, or RSA) as a dependent variable. Extraversion (NEO-FFI), subjective stress, and physiological stress were measured in 166 undergraduate students randomly assigned to undergo moderate (n=82) or high-intensity (n=84) social stress (a public speaking task with different levels of social evaluation). All participants underwent continuous physiological monitoring while facing two consecutive stress exposures distributed across five laboratory phases: baseline, stress exposure 1, post-stress 1, stress exposure 2, post-stress 2. Results indicated that under moderate-intensity social stress, participants higher on extraversion exhibited lesser HR reactivity to stress than participants lower on extraversion, while under high-intensity social stress, they exhibited greater HR, SBP, DBP and RSA reactivity. Under both moderate- and high-intensity social stress, participants higher on extraversion exhibited pronounced SBP and DBP response adaptation to repeated stress, and showed either better degree of HR recovery or greater amount of SBP and DBP recovery after stress. These findings suggest that individuals higher on extraversion exhibit physiological flexibility to cope with social challenges and benefit from adaptive cardiovascular responses. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Design and Calibration Tests of an Active Sound Intensity Probe

    Directory of Open Access Journals (Sweden)

    Thomas Kletschkowski

    2008-01-01

    Full Text Available The paper presents an active sound intensity probe that can be used for sound source localization in standing wave fields. The probe consists of a sound hard tube that is terminated by a loudspeaker and an integrated pair of microphones. The microphones are used to decompose the standing wave field inside the tube into its incident and reflected part. The latter is cancelled by an adaptive controller that calculates proper driving signals for the loudspeaker. If the open end of the actively controlled tube is placed close to a vibrating surface, the radiated sound intensity can be determined by measuring the cross spectral density between the two microphones. A one-dimensional free field can be realized effectively, as first experiments performed on a simplified test bed have shown. Further tests proved that a prototype of the novel sound intensity probe can be calibrated.

  20. Description and operation of the LEDA beam-position/intensity measurement module

    International Nuclear Information System (INIS)

    Rose, C.R.; Stettler, M.W.

    1997-01-01

    This paper describes the specification, design and preliminary operation of the beam-position/intensity measurement module being built for the Low Energy Demonstration Accelerator (LEDA) and Accelerator Production of Tritium (APT) projects at Los Alamos National Laboratory. The module, based on the VXI footprint, is divided into three sections: first, the analog front-end which consists of logarithmic amplifiers, anti-alias filters, and digitizers; second, the digital-to-analog section for monitoring signals on the front panel; and third, the DSP, error correction, and VXI-interface section. Beam position is calculated based on the log-ratio transfer function. The module has four, 2-MHz, IF inputs suitable for two-axis position measurements. It has outputs in both digital and analog format for x- and y-position and beam intensity. Real-time error-correction is performed on the four input signals after they are digitized and before calculating the beam position to compensate for drift, offsets, gain non-linearities, and other systematic errors. This paper also describes how the on-line error-correction is implemented digitally and algorithmically

  1. Suppression of Repeat-Intensive False Targets Based on Temporal Pulse Diversity

    Directory of Open Access Journals (Sweden)

    Gang Lu

    2013-01-01

    Full Text Available This paper considers the problem of suppressing the repeat-intensive false targets produced by a deception electronic attack (EA system equipped with a Digital Radio Frequency Memory (DRFM device. Different from a conventional repeat jammer, this type of jamming intensively retransmits the intercepted signal stored in a DRFM to the victim radar in a very short time-delay interval relative to a radar pulse wide. A multipeak matched-filtering output is then produced other than the merely expected true target. An electronic protection (EP algorithm based on the space time block code (STBC is proposed to suppress the adverse effects of this jammer. By transmitting a pulse sequence generated from the STBC in succession and the following cancellation process applied upon the received signal, this algorithm performs successfully in a single antenna system provided that the target models are nonfluctuating or slow fluctuating and the pulse repetition frequency (PRF is comparatively high. The performance in white and correlated Gaussian disturbance is evaluated by means of Monte Carlo simulations.

  2. Higher Plants in Space: Microgravity Perception, Response, and Adaptation

    Science.gov (United States)

    Zheng, Hui Qiong; Han, Fei; Le, Jie

    2015-11-01

    Microgravity is a major abiotic stress in space. Its effects on plants may depend on the duration of exposure. We focused on two different phases of microgravity responses in space. When higher plants are exposed to short-term (seconds to hours) microgravity, such as on board parabolic flights and sounding rockets, their cells usually exhibit abiotic stress responses. For example, Ca 2+-, lipid-, and pH-signaling are rapidly enhanced, then the production of reactive oxygen species and other radicals increase dramatically along with changes in metabolism and auxin signaling. Under long-term (days to months) microgravity exposure, plants acclimatize to the stress by changing their metabolism and oxidative response and by enhancing other tropic responses. We conclude by suggesting that a systematic analysis of regulatory networks at the molecular level of higher plants is needed to understand the molecular signals in the distinct phases of the microgravity response and adaptation.

  3. Microstructural Analysis of Carbonyl Signal in the 13C NMR Spectra of Methyl Methacrylate - n-Butyl Acrylate Copolymer

    International Nuclear Information System (INIS)

    Bujak, P.; Matlengiewicz, M.

    2005-01-01

    Microstructural information on acrylic copolymers, i.e. distribution of the comonomers along the macromolecular chain and their stereochemical arrangement (tacticity) can be derived from 13 C NMR, analyzing the splitting of their carbonyl signal. In the 100 MHz 13 C NMR spectrum of poly(methyl methacrylate-co-n-butyl acrylate), PMMA-nBA, the carbonyl signal at 174-178,5 ppm is clearly split into the lines of configurational-compositional pentads. This splitting is slightly different in different solvents, hence, recording of the same sample in different solvents may reveal differences important to correct assignment of individual sequences, since their probabilities (intensities) remain the same, while the chemical shift can vary in different solvents. If we would like to perform a complete analysis at this level we have to determine the distribution of 272 individual pentads. The outermost lines in the carbonyl signal of the copolymer can be assigned to the sequences of pure composition by simple comparison with the spectra of respective homopolymers. The rest of the inner lines cannot be easily attributed, therefore, a series of copolymer samples of different composition were synthesized in order to observe the different heterosequences, since depending on copolymer composition, different signals representing individual sequences, assume different relative intensities. To confirm the correctness of proposed attribution a simulation of the carbonyl signal can be performed. It is therefore necessary to know the intensities and positions of individual signals, representing individual compositional-configurational pentads. Calculation of the intensity of the lines can be performed assuming Bernoullian and/or Markov statistics, separately for compositional and configurational sequences and verifying the overall distribution of the individual probabilities. The position of the individual lines cannot be straightforwardly determined, therefore, we have adopted an

  4. Statistical Signal Processing by Using the Higher-Order Correlation between Sound and Vibration and Its Application to Fault Detection of Rotational Machine

    Directory of Open Access Journals (Sweden)

    Hisako Masuike

    2008-01-01

    Full Text Available In this study, a stochastic diagnosis method based on the changing information of not only a linear correlation but also a higher-order nonlinear correlation is proposed in a form suitable for online signal processing in time domain by using a personal computer, especially in order to find minutely the mutual relationship between sound and vibration emitted from rotational machines. More specifically, a conditional probability hierarchically reflecting various types of correlation information is theoretically derived by introducing an expression on the multidimensional probability distribution in orthogonal expansion series form. The effectiveness of the proposed theory is experimentally confirmed by applying it to the observed data emitted from a rotational machine driven by an electric motor.

  5. Use of higher order signal moments and high speed digital sampling technique for neutron flux measurements

    Science.gov (United States)

    Baers, L. B.; Gutierrez, T. Rivero; Mendoza, R. A. Carrillo; Santana, G. Jimenez

    1993-08-01

    The second (conventional variance or Campbell signal), the third, and the modified fourth order central signal moments associated with the amplified and filtered currents from two electrodes of an ex-core neutron sensitive fission detector were measured versus the reactor power of the 1-MW TRIGA reactor in Mexico City. Two channels of a high-speed (400-MHz) multiplexing data sampler and an analog-to-digital converter with 12-b resolution and 1-Mword buffer memory were used. The data were further retrieved into a PC, and estimates for autocorrelation and cross-correlation moments up to the fifth order, coherence, skewness, excess, etc., quantities were calculated offline. Five-mode operation of the detector was achieved, including conventional counting rates and currents in agreement with theory and the authors' previous results with analog techniques. The signals are proportional to the neutron flux and reactor power in some flux ranges. The suppression of background noise is improved and the lower limit of the measurement range is extended as the order of moment is increased, in agreement with theory.

  6. Can You Be Hit by Your Partner and Be Intensely in Love?

    Science.gov (United States)

    Graña, José Luis; Cuenca Montesino, María Luisa; Redondo, Natalia; O'Leary, K Daniel

    2016-07-01

    This study examines, in a multilevel context, the influence of intensity of love at an individual level on couples' mean reports of psychological and physical aggression in a sample of 2,988 adult couples of both sexes from the Region of Madrid. The percentages of intimate partner aggression considering the highest report of aggression in the couple were around 60% of psychological aggression and 15% of physical aggression. Multilevel models confirm that individuals who were less intensely in love reported a higher level of psychological aggression. Concerning physical aggression, men who declared they were less intensely in love reported a higher level of physical aggression by their partners, but this pattern was not found in the women. Therefore, psychological aggression plays a more relevant role in the intensity of love than physical aggression. © The Author(s) 2015.

  7. Echolocation call intensity and directionality in flying short-tailed fruit bats, Carollia perspicillata (Phyllostomidae)

    DEFF Research Database (Denmark)

    Brinkløv, Signe; Jakobsen, Lasse; Ratcliffe, John M

    2011-01-01

    The directionality of bat echolocation calls defines the width of bats' sonar "view," while call intensity directly influences detection range since adequate sound energy must impinge upon objects to return audible echoes. Both are thus crucial parameters for understanding biosonar signal design....... a longer and narrower sonar range than previously thought. C. perspicillata orient and forage in the forest interior and the narrow beam might be adaptive in clutter, by reducing the number and intensity of off-axis echoes....

  8. Influence of longitudinal position on the evolution of steady-state signal in cardiac cine balanced steady-state free precession imaging.

    Science.gov (United States)

    Spear, Tyler J; Stromp, Tori A; Leung, Steve W; Vandsburger, Moriel H

    2017-11-01

    Emerging quantitative cardiac magnetic resonance imaging (CMRI) techniques use cine balanced steady-state free precession (bSSFP) to measure myocardial signal intensity and probe underlying physiological parameters. This correlation assumes that steady-state is maintained uniformly throughout the heart in space and time. To determine the effects of longitudinal cardiac motion and initial slice position on signal deviation in cine bSSFP imaging by comparing two-dimensional (2D) and three-dimensional (3D) acquisitions. Nine healthy volunteers completed cardiac MRI on a 1.5-T scanner. Short axis images were taken at six slice locations using both 2D and 3D cine bSSFP. 3D acquisitions spanned two slices above and below selected slice locations. Changes in myocardial signal intensity were measured across the cardiac cycle and compared to longitudinal shortening. For 2D cine bSSFP, 46% ± 9% of all frames and 84% ± 13% of end-diastolic frames remained within 10% of initial signal intensity. For 3D cine bSSFP the proportions increased to 87% ± 8% and 97% ± 5%. There was no correlation between longitudinal shortening and peak changes in myocardial signal. The initial slice position significantly impacted peak changes in signal intensity for 2D sequences ( P  cine bSSFP that is only restored at the center of a 3D excitation volume. During diastole, a transient steady-state is established similar to that achieved with 3D cine bSSFP regardless of slice location.

  9. Effect of LIPUS on inflammatory factors, cell apoptosis and integrin signaling pathway in osteoarthritis animal models

    Directory of Open Access Journals (Sweden)

    Li-Cai Zhang

    2017-05-01

    Full Text Available Objective: To study the effect of low-intensity pulsed ultrasound (LIPUS on inflammatory factors, cell apoptosis and integrin signaling pathway in osteoarthritis animal models. Methods: Male New Zealand white rabbits were selected as the experimental animals and randomly divided into sham group, osteoarthritis model group (OA group and LIPUS intervention group (LIPUS group, animal models with osteoarthritis in hind limb knee joint were established and then given LIPUS intervention. 6 weeks after the intervention, the articular cartilage was separated to detect the expression of inflammatory factors, cell apoptosis molecules and integrin signaling pathway molecules. Results: OPN, NO, IL-1β, TNF-α, Fas, FasL, LC3-II, Beclin-1, Integrinβ1, FAK, ERK1/2, JNK, p38MAPK, MMP-1 and MMP-3 protein expression in articular cartilage of OA group were significantly higher than those of Sham group while Col-I and Col-II protein expression were significantly lower than those of Sham group; OPN, NO, IL-1β, TNF-α, Fas, FasL, LC3-II, Beclin-1, Integrinβ1, FAK, ERK1/2, JNK, p38MAPK, MMP-1 and MMP-3 protein expression in articular cartilage of LIPUS group were significantly lower than those of OA group while Col-I and Col-II protein expression were significantly higher than those of OA group. Conclusion: LIPUS has inhibiting effect on the inflammation, apoptosis and integrin signaling pathway in articular cartilage of osteoarthritis animal models, and it can promote the repair of articular cartilage.

  10. Stressful life events and acute kidney injury in intensive and semi-intensive care unities.

    Science.gov (United States)

    Diniz, Denise Para; Marques, Daniella Aparecida; Blay, Sérgio Luis; Schor, Nestor

    2012-03-01

    Several studies point out that pathophysiological changes related to stress may influence renal function and are associated with disease onset and evolution. However, we have not found any studies about the influence of stress on renal function and acute kidney injury. To evaluate the association between stressful life events and acute kidney injury diagnosis, specifying the most stressful classes of events for these patients in the past 12 months. Case-control study. The study was carried out at Hospital São Paulo, in Universidade Federal de São Paulo and at Hospital dos Servidores do Estado de São Paulo, in Brazil. Patients with acute kidney injury and no chronic disease, admitted to the intensive or semi-intensive care units were included. Controls included patients in the same intensive care units with other acute diseases, except for the acute kidney injury, and also with no chronic disease. Out of the 579 patients initially identified, 475 answered to the Social Readjustment Rating Scale (SRRS) questionnaire and 398 were paired by age and gender (199 cases and 199 controls). The rate of stressful life events was statistically similar between cases and controls. The logistic regression analysis to detect associated effects of the independent variables to the stressful events showed that: increasing age and economic classes A and B in one of the hospitals (Hospital São Paulo - UNIFESP) increased the chance of a stressful life event (SLE). This study did not show association between the Acute Kidney Injury Group with a higher frequency of stressful life events, but that old age, higher income, and type of clinical center were associated.

  11. Precise signal amplitude retrieval for a non-homogeneous diagnostic beam using complex interferometry approach

    Science.gov (United States)

    Krupka, M.; Kalal, M.; Dostal, J.; Dudzak, R.; Juha, L.

    2017-08-01

    Classical interferometry became widely used method of active optical diagnostics. Its more advanced version, allowing reconstruction of three sets of data from just one especially designed interferogram (so called complex interferogram) was developed in the past and became known as complex interferometry. Along with the phase shift, which can be also retrieved using classical interferometry, the amplitude modifications of the probing part of the diagnostic beam caused by the object under study (to be called the signal amplitude) as well as the contrast of the interference fringes can be retrieved using the complex interferometry approach. In order to partially compensate for errors in the reconstruction due to imperfections in the diagnostic beam intensity structure as well as for errors caused by a non-ideal optical setup of the interferometer itself (including the quality of its optical components), a reference interferogram can be put to a good use. This method of interferogram analysis of experimental data has been successfully implemented in practice. However, in majority of interferometer setups (especially in the case of the ones employing the wavefront division) the probe and the reference part of the diagnostic beam would feature different intensity distributions over their respective cross sections. This introduces additional error into the reconstruction of the signal amplitude and the fringe contrast, which cannot be resolved using the reference interferogram only. In order to deal with this error it was found that additional separately recorded images of the intensity distribution of the probe and the reference part of the diagnostic beam (with no signal present) are needed. For the best results a sufficient shot-to-shot stability of the whole diagnostic system is required. In this paper, efficiency of the complex interferometry approach for obtaining the highest possible accuracy of the signal amplitude reconstruction is verified using the computer

  12. Microstructural characteristics of the hydroxyapatite and its influence in the Tl signal induced by gamma radiation

    International Nuclear Information System (INIS)

    Mendoza A, D.; Gonzalez M, P.R.; Hernandez A, M.; Estrada G, R.; Rodriguez L, V.

    2003-01-01

    The analysis carried out on different materials has shown that the quantity and type of dopants play an important role in the behaviour thermoluminescent signal induced by the ionizing radiation. More recent studies have also shown that the grain size influences strongly in the thermoluminescent signal. Plus still, the crystal growth habit and the crystalline degree have an important effect in the type and intensity thermoluminescent signal. In this sense, we present this work on the analysis of the thermoluminescent signal induced by the gamma radiation in the hydroxyapatite ceramic. Depending the growth habit, a variation of the peak temperature location, signal intensity and linearity range was observed; in particular cases a lineal relationship between glow curve and radiation dose was in the range from 2 to 1000 Gray. These results are complemented with a microstructural and crystalline degree analysis through scanning electron microscopy and X-ray Diffraction. The dose-response over the whole irradiation range opening up the possibility of employing this bio material as a dosimeter. (Author)

  13. The Intensity of Human Body Odors and the MHC: Should We Expect a Link?

    Directory of Open Access Journals (Sweden)

    Claus Wedekind

    2006-01-01

    Full Text Available It is now well established that genes within the major histocompatibility complex (MHC somehow affect the production of body odors in several vertebrates, including humans. Here we discuss whether variation in the intensity of body odors may be influenced by the MHC. In order to examine this question, we have to control for MHC-linked odor perception on the smeller's side. Such a control is necessary because the perception of pleasantness and intensity seem to be confounded, and the causalities are still unsolved. It has previously been found that intense odors are scored as less pleasant if the signaler and the receiver are of MHC-dissimilar type, but not if they are of MHC similar type. We argue, and first data suggest, that an effect of the degree of MHC-heterozygosity and odor intensity is likely (MHC-homozygotes may normally smell more intense, while there is currently no strong argument for other possible links between the MHC and body odor intensity.

  14. Altered carotid plaque signal among different repetition times on T1-weighted magnetic resonance plaque imaging with self-navigated radial-scan technique

    Energy Technology Data Exchange (ETDEWEB)

    Narumi, Shinsuke; Ohba, Hideki; Mori, Kiyofumi; Ohura, Kazumasa; Ono, Ayumi; Terayama, Yasuo [Iwate Medical University, Department of Neurology and Gerontology, Morioka (Japan); Sasaki, Makoto [Iwate Medical University, Advanced Medical Research Center, Morioka (Japan); Ogasawara, Kuniaki [Iwate Medical University, Department of Neurosurgery, Morioka (Japan); Hitomi, Jiro [Iwate Medical University, Department of Anatomy, Morioka (Japan)

    2010-04-15

    Magnetic resonance (MR) plaque imaging for carotid arteries is usually performed by using an electrocardiograph (ECG)-gating technique to eliminate pulsation-related artifacts, which can affect the plaque signals because of varied repetition time (TR) among patients. Hence, we investigated whether differences in TR causes signal alterations of the carotid plaque by using a non-gated plaque imaging technique. We prospectively examined 19 patients with carotid stenosis by using a T1-weighted self-navigated radial-scan technique with TRs of 500, 700, and 900 ms. The signal intensity of the carotid plaque was measured, and the contrast ratio (CR) relative to the adjacent muscle was calculated. CRs of the carotid plaques were 1.39 {+-} 0.39, 1.29 {+-} 0.29, and 1.23 {+-} 0.24 with TRs of 500, 700, and 900 ms, respectively, and were significantly different. Among the plaques, those with a hyperintensity signal (CR > 1.5) and moderate-intensity signal (CR 1.2-1.5) at 500 ms showed a TR-dependent signal decrease (hyperintensity plaques, 1.82 {+-} 0.26; 1.61 {+-} 0.19; and 1.48 {+-} 0.17; moderate-intensity plaques, 1.33 {+-} 0.08; 1.26 {+-} 0.08; and 1.19 {+-} 0.07), while those with an isointensity signal (CR < 1.2) remained unchanged regardless of TR (0.96 {+-} 0.12, 0.96 {+-} 0.11, and 0.97 {+-} 0.13). The signal intensity of the carotid plaque on T1-weighted imaging significantly varies among different TRs and tends to decrease with longer TR. MR plaque imaging with short and constant TR settings that the ECG-gating method cannot realize would be preferable for evaluating plaque characteristics. (orig.)

  15. Muonic X-ray intensities in phosphorus- and selenium modifications

    International Nuclear Information System (INIS)

    Kaeser, K.; Robert-Tissot, B.; Schaller, L.A.; Schellenberg, L.; Schneuwly, H.

    1979-01-01

    Muonic X-ray intensity measurements have been performed at SIN on allotropic modifications of phosphorus (white, red and black) and of selenium (red and black). Structure effects have been found in the intensity ratios of the K-series between amorphous and crystalline modifications of the same element. The effect in the higher series (Se) is less pronounced. On the other hand, the two crystalline phosphorus modifications (red and black) show the same intensity behavior. The root-mean-square radii 2 >sup(1/2) of phosphorus and (natural) selenium were found to be 3.187(3) fm and 4.138(1) fm respectively. (Auth.)

  16. Foreground Subtraction and Signal reconstruction in redshifted 21cm Global Signal Experiments using Artificial Neural Networks

    Science.gov (United States)

    Choudhury, Madhurima; Datta, Abhirup

    2018-05-01

    Observations of HI 21cm transition line is a promising probe into the Dark Ages and Epoch-of-Reionization. Detection of this redshifted 21cm signal is one of the key science goal for several upcoming low-frequency radio telescopes like HERA, SKA and DARE. Other global signal experiments include EDGES, LEDA, BIGHORNS, SCI-HI, SARAS. One of the major challenges for the detection of this signal is the accuracy of the foreground source removal. Several novel techniques have been explored already to remove bright foregrounds from both interferometric as well as total power experiments. Here, we present preliminary results from our investigation on application of ANN to detect 21cm global signal amidst bright galactic foreground. Following the formalism of representing the global 21cm signal by 'tanh' model, this study finds that the global 21cm signal parameters can be accurately determined even in the presence of bright foregrounds represented by 3rd order log-polynomial or higher.

  17. Signal alteration of the cochlear perilymph on 3 different sequences after intratympanic Gd-DTPA administration at 3 tesla. Comparison of 3D-FLAIR, 3D-T1-weighted imaging, and 3D-CISS

    International Nuclear Information System (INIS)

    Yamazaki, Masahiro; Naganawa, Shinji; Kawai, Hisashi; Nihashi, Takashi; Nakashima, Tsutomu

    2010-01-01

    Three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) imaging after intratympanic gadolinium injection is useful for pathophysiologic and morphologic analysis of the inner ear. However, statistical analysis of differences in inner ear signal intensity among 3D-FLAIR and other sequences has not been reported. We evaluated the signal intensity of cochlear fluid on each of 3D-FLAIR, 3D-T 1 -weighted imaging (T 1 WI), and 3D-constructive interference in the steady state (CISS) to clarify the differences in contrast effect among these 3 sequences using intratympanic gadolinium injection. Twenty-one patients underwent 3D-FLAIR, 3D-T 1 WI, and 3D-CISS imaging at 3 tesla 24 hours after intratympanic injection of gadolinium. We determined regions of interest of the cochleae (C) and medulla oblongata (M) on each image, evaluated the signal intensity ratio between C and M (CM ratio), and determined the ratio of cochlear signal intensity of the injected side to that of the non-injected side (contrast value). The CM ratio of the injected side (3.00±1.31, range, 0.53 to 4.88, on 3D-FLAIR; 0.83±0.30, range, 0.36 to 1.58 on 3D-T 1 WI) was significantly higher than that of the non-injected side (0.52±0.14, range, 0.30 to 0.76 on 3D-FLAIR; 0.49±0.11, range, 0.30 to 0.71 on 3D-T 1 WI) on 3D-FLAIR and 3D-T 1 WI (P 1 WI (1.73±0.60 range, 0.98 to 3.09) (P<0.001). The 3D-FLAIR sequence is the most sensitive for observing alteration in inner ear fluid signal after intratympanic gadolinium injection. Our results warrant use of 3D-FLAIR as a sensitive imaging technique to clarify the pathological and morphological mechanisms of disorders of the inner ear. (author)

  18. Exercise and dietary change ameliorate high fat diet induced obesity and insulin resistance via mTOR signaling pathway.

    Science.gov (United States)

    Bae, Ju Yong; Shin, Ki Ok; Woo, Jinhee; Woo, Sang Heon; Jang, Ki Soeng; Lee, Yul Hyo; Kang, Sunghwun

    2016-06-01

    The purpose of this study was to investigate the effect of exercise and dietary change on obesity and insulin resistance and mTOR signaling protein levels in skeletal muscles of obese rats. Sixty male Sprague-Dawley rats were divided into CO (Normal diet) and HF (High Fat diet) groups in order to induce obesity for 15 weeks. The rats were then subdivided into CO, COT (CO + Training), HF, HFT (HF + Training), HFND (Dietary change), and HFNDT (HFND + Training) groups (10 rats / group). The training groups underwent moderate-intensity treadmill exercise for 8 weeks, after which soleus muscles were excised and analyzed. Data was statistically analyzed by independent t-test and One-way ANOVA tests with a 0.05 significance level. Fasting blood glucose, plasma insulin, and HOMA-IR in the HF group were significantly higher, as compared with other groups (p continuous high fat intake, regular exercise and dietary change showed a positive effect on insulin resistance and mTOR signaling protein levels.

  19. Generation of Ultra-high Intensity Laser Pulses

    International Nuclear Information System (INIS)

    Fisch, N.J.; Malkin, V.M.

    2003-01-01

    Mainly due to the method of chirped pulse amplification, laser intensities have grown remarkably during recent years. However, the attaining of very much higher powers is limited by the material properties of gratings. These limitations might be overcome through the use of plasma, which is an ideal medium for processing very high power and very high total energy. A plasma can be irradiated by a long pump laser pulse, carrying significant energy, which is then quickly depleted in the plasma by a short counterpropagating pulse. This counterpropagating wave effect has already been employed in Raman amplifiers using gases or plasmas at low laser power. Of particular interest here are the new effects which enter in high power regimes. These new effects can be employed so that one high-energy optical system can be used like a flashlamp in what amounts to pumping the plasma, and a second low-power optical system can be used to extract quickly the energy from the plasma and focus it precisely. The combined system can be very compact. Thus, focused intensities more than 10 25 W/cm 2 can be contemplated using existing optical elements. These intensities are several orders of magnitude higher than what is currently available through chirped pump amplifiers

  20. Signal analysis for failure detection

    International Nuclear Information System (INIS)

    Parpaglione, M.C.; Perez, L.V.; Rubio, D.A.; Czibener, D.; D'Attellis, C.E.; Brudny, P.I.; Ruzzante, J.E.

    1994-01-01

    Several methods for analysis of acoustic emission signals are presented. They are mainly oriented to detection of changes in noisy signals and characterization of higher amplitude discrete pulses or bursts. The aim was to relate changes and events with failure, crack or wear in materials, being the final goal to obtain automatic means of detecting such changes and/or events. Performance evaluation was made using both simulated and laboratory test signals. The methods being presented are the following: 1. Application of the Hopfield Neural Network (NN) model for classifying faults in pipes and detecting wear of a bearing. 2. Application of the Kohonnen and Back Propagation Neural Network model for the same problem. 3. Application of Kalman filtering to determine time occurrence of bursts. 4. Application of a bank of Kalman filters (KF) for failure detection in pipes. 5. Study of amplitude distribution of signals for detecting changes in their shape. 6. Application of the entropy distance to measure differences between signals. (author). 10 refs, 11 figs