WorldWideScience

Sample records for higher load factor

  1. Dynamical load factor of impact loaded shell structures

    International Nuclear Information System (INIS)

    Hammel, J.

    1977-01-01

    Dynamical loaded structures can be analysed by spectral representations, which usually lead to an enormous computational effort. If it is possible to find a fitting dynamical load factor, the dynamical problem can be reduced to a statical one. The computation of this statical problem is much simpler. The disadvantage is that the dynamical load factor usually leads to a very rough approximation. In this paper it will be shown, that by combination of these two methods, the approximation of the dynamical load factor can be improved and the consumption of computation time can be enormously reduced. (Auth.)

  2. Consideration of higher seismic loads at existing plants

    Energy Technology Data Exchange (ETDEWEB)

    Liebig, J.; Pellissetti, M.

    2015-07-01

    Because of advancement of methods in probabilistic seismic hazard analysis, plenty of existing plants face higher seismic loads as an obligation from the national authorities. In case of such obligations safety related structures and equipment have to be reevaluated or requalified for the increased seismic loads. The paper provides solutions for different kinds of structures and equipment inside the plant, avoiding cost intensive hardware exchange. Due to higher seismic loads different kinds of structures and equipment inside a plant have to be reevaluated. For civil structures, primary components, mechanical components, distribution lines and electrical and I&C equipment different innovative concepts will be applied to keep structures and equipment qualified for the higher seismic loads. Detailed analysis, including the modeling of non-linear phenomena, or minor structural upgrades are cost competitive, compared to cost intensive hardware exchanges. Several case studies regarding the re-evaluation and requalification of structures and equipment due to higher seismic loads are presented. It is shown how the creation of coupled finite element models and the consistent propagation of acceleration time histories through the soil, building and primary circuit lead to a significant load reduction Electrical and I&C equipment is reinforced by smart upgrades which increase the natural equipment frequencies. Therefore for all devices inside the cabinets the local acceleration will not increase and the seismic qualification will be maintained. The case studies cover both classical deterministic and probabilistic re-evaluations (fragility analysis). Furthermore, the substantial benefits of non-linear limit load evaluation, such as push-over analysis of buildings and limit load analysis of fuel assemblies, are demonstrated. (Author)

  3. Higher- and Lower-Order Factor Analyses of the Temperament in Middle Childhood Questionnaire

    Science.gov (United States)

    Kotelnikova, Yuliya; Olino, Thomas M.; Klein, Daniel N.; Mackrell, Sarah V.M.; Hayden, Elizabeth P.

    2017-01-01

    The Temperament in Middle Childhood Questionnaire (TMCQ; Simonds & Rothbart, 2004) is a widely used parent-report measure of temperament. However, neither its lower- nor higher-order structures have been tested via a bottom-up, empirically based approach. We conducted higher- and lower-order exploratory factor analyses (EFAs) of the TMCQ in a large (N = 654) sample of 9-year-olds. Item-level EFAs identified 92 items as suitable (i.e., with loadings ≥.40) for constructing lower-order factors, only half of which resembled a TMCQ scale posited by the measure’s authors. Higher-order EFAs of the lower-order factors showed that a three-factor structure (Impulsivity/Negative Affectivity, Negative Affectivity, and Openness/Assertiveness) was the only admissible solution. Overall, many TMCQ items did not load well onto a lower-order factor. In addition, only three factors, which did not show a clear resemblance to Rothbart’s four-factor model of temperament in middle childhood, were needed to account for the higher-order structure of the TMCQ. PMID:27002124

  4. 14 CFR 31.23 - Flight load factor.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flight load factor. 31.23 Section 31.23... STANDARDS: MANNED FREE BALLOONS Strength Requirements § 31.23 Flight load factor. In determining limit load, the limit flight load factor must be at least 1.4. ...

  5. 14 CFR 27.337 - Limit maneuvering load factor.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Limit maneuvering load factor. 27.337... Limit maneuvering load factor. The rotorcraft must be designed for— (a) A limit maneuvering load factor... load factor not less than 2.0 and any negative limit maneuvering load factor of not less than −0.5 for...

  6. 14 CFR 29.337 - Limit maneuvering load factor.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Limit maneuvering load factor. 29.337... Limit maneuvering load factor. The rotorcraft must be designed for— (a) A limit maneuvering load factor... load factor not less than 2.0 and any negative limit maneuvering load factor of not less than −0.5 for...

  7. 14 CFR 398.9 - Load factor standards.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Load factor standards. 398.9 Section 398.9... STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.9 Load factor standards. The load factor standards used in this part may be raised for individual eligible places under...

  8. Factor structure underlying components of allostatic load.

    Directory of Open Access Journals (Sweden)

    Jeanne M McCaffery

    Full Text Available Allostatic load is a commonly used metric of health risk based on the hypothesis that recurrent exposure to environmental demands (e.g., stress engenders a progressive dysregulation of multiple physiological systems. Prominent indicators of response to environmental challenges, such as stress-related hormones, sympatho-vagal balance, or inflammatory cytokines, comprise primary allostatic mediators. Secondary mediators reflect ensuing biological alterations that accumulate over time and confer risk for clinical disease but overlap substantially with a second metric of health risk, the metabolic syndrome. Whether allostatic load mediators covary and thus warrant treatment as a unitary construct remains to be established and, in particular, the relation of allostatic load parameters to the metabolic syndrome requires elucidation. Here, we employ confirmatory factor analysis to test: 1 whether a single common factor underlies variation in physiological systems associated with allostatic load; and 2 whether allostatic load parameters continue to load on a single common factor if a second factor representing the metabolic syndrome is also modeled. Participants were 645 adults from Allegheny County, PA (30-54 years old, 82% non-Hispanic white, 52% female who were free of confounding medications. Model fitting supported a single, second-order factor underlying variance in the allostatic load components available in this study (metabolic, inflammatory and vagal measures. Further, this common factor reflecting covariation among allostatic load components persisted when a latent factor representing metabolic syndrome facets was conjointly modeled. Overall, this study provides novel evidence that the modeled allostatic load components do share common variance as hypothesized. Moreover, the common variance suggests the existence of statistical coherence above and beyond that attributable to the metabolic syndrome.

  9. Load factors to end March 1989

    International Nuclear Information System (INIS)

    Howles, L.

    1989-01-01

    Load factors for nuclear reactors of 150MWe gross and above for the 12 month period up to the end of March 1989, and over their lifetimes, are tabulated. Units which have been in operation for more than one year as of end March 1989 are ranked in order of annual load factor; cumulative load factors are also shown, measured from first synchronization to the grid not from start of commercial operation. New reactors which had operated for less than 12 months as of end of March 1989 are listed separately. With the exception of the four Paks units in Hungary, Comecon reactors are excluded due to lack of data. (author)

  10. Means of achieving high load factors at Olkiluoto 1 and 2

    International Nuclear Information System (INIS)

    Patrakka, E.

    2001-01-01

    Teollisuuden Voima Oy operates two BWR units Olkiluoto 1 and 2 that have achieved load factors typically higher than 90%. The operating experiences gained in the 1990s is summarised and the factors contributing to the high capacity factors are addressed. These include the general objectives for operation and maintenance, plant modernisation programme, maintenance principles, and outage policy and experiences. Finally, the international evaluations performed at Olkiluoto are mentioned. (author)

  11. Load factor trends in light water reactor units

    International Nuclear Information System (INIS)

    Lehtinen, E.A.

    1990-01-01

    The Technical Research Centre of Finland follows up and analyses nuclear power plant availability performances worldwide. The results of a trend study for the load factors of the LWR units have been updated to the end of 1987. The whole operating history, in the sense of the annual and cumulative load factors achieved by all the Western commercial LWR units until the end of 1987, has been taken into consideration. Some trends in the load factors have been identified by using an exponential regression model developed. The LWR units form quite an inhomogeneous population with respect to their age, technical characteristics, site country as well as cumulative load factors achieved. The cumulative load factors achieved by all the LWR units until the end of 1987 are presented individually in the scattergrams

  12. Impact of measurement uncertainty from experimental load distribution factors on bridge load rating

    Science.gov (United States)

    Gangone, Michael V.; Whelan, Matthew J.

    2018-03-01

    Load rating and testing of highway bridges is important in determining the capacity of the structure. Experimental load rating utilizes strain transducers placed at critical locations of the superstructure to measure normal strains. These strains are then used in computing diagnostic performance measures (neutral axis of bending, load distribution factor) and ultimately a load rating. However, it has been shown that experimentally obtained strain measurements contain uncertainties associated with the accuracy and precision of the sensor and sensing system. These uncertainties propagate through to the diagnostic indicators that in turn transmit into the load rating calculation. This paper will analyze the effect that measurement uncertainties have on the experimental load rating results of a 3 span multi-girder/stringer steel and concrete bridge. The focus of this paper will be limited to the uncertainty associated with the experimental distribution factor estimate. For the testing discussed, strain readings were gathered at the midspan of each span of both exterior girders and the center girder. Test vehicles of known weight were positioned at specified locations on each span to generate maximum strain response for each of the five girders. The strain uncertainties were used in conjunction with a propagation formula developed by the authors to determine the standard uncertainty in the distribution factor estimates. This distribution factor uncertainty is then introduced into the load rating computation to determine the possible range of the load rating. The results show the importance of understanding measurement uncertainty in experimental load testing.

  13. 14 CFR 23.527 - Hull and main float load factors.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hull and main float load factors. 23.527... Water Loads § 23.527 Hull and main float load factors. (a) Water reaction load factors nw must be...=seaplane landing weight in pounds. (6) K1=empirical hull station weighing factor, in accordance with figure...

  14. An alternative method for centrifugal compressor loading factor modelling

    Science.gov (United States)

    Galerkin, Y.; Drozdov, A.; Rekstin, A.; Soldatova, K.

    2017-08-01

    The loading factor at design point is calculated by one or other empirical formula in classical design methods. Performance modelling as a whole is out of consideration. Test data of compressor stages demonstrates that loading factor versus flow coefficient at the impeller exit has a linear character independent of compressibility. Known Universal Modelling Method exploits this fact. Two points define the function - loading factor at design point and at zero flow rate. The proper formulae include empirical coefficients. A good modelling result is possible if the choice of coefficients is based on experience and close analogs. Earlier Y. Galerkin and K. Soldatova had proposed to define loading factor performance by the angle of its inclination to the ordinate axis and by the loading factor at zero flow rate. Simple and definite equations with four geometry parameters were proposed for loading factor performance calculated for inviscid flow. The authors of this publication have studied the test performance of thirteen stages of different types. The equations are proposed with universal empirical coefficients. The calculation error lies in the range of plus to minus 1,5%. The alternative model of a loading factor performance modelling is included in new versions of the Universal Modelling Method.

  15. Probability based load factors for design of concrete containment structures

    International Nuclear Information System (INIS)

    Hwang, H.; Kagami, S.; Reich, M.; Ellingwood, B.; Shinozuka, M.

    1985-01-01

    This paper describes a procedure for developing probability-based load combinations for the design of concrete containments. The proposed criteria are in a load and resistance factor design (LRFD) format. The load factors and resistance factors are derived for use in limit states design and are based on a target limit state probability. In this paper, the load factors for accident pressure and safe shutdown earthquake are derived for three target limit state probabilities. Other load factors are recommended on the basis of prior experience with probability-based design criteria for ordinary building construction. 6 refs

  16. Reliability-based load and resistance factor design for piping: an exploratory case study

    International Nuclear Information System (INIS)

    Gupta, Abhinav; Choi, Byounghoan

    2003-01-01

    This paper presents an exploratory case study on the application of Load and Resistance Factor Design (LRFD) approach to the Section III of ASME Boiler and Pressure Vessel code for piping design. The failure criterion for defining the performance function is considered as plastic instability. Presently used design equation is calibrated by evaluating the minimum reliability levels associated with it. If the target reliability in the LRFD approach is same as that evaluated for the presently used design equation, it is shown that the total safety factors for the two design equations are identical. It is observed that the load and resistance factors are not dependent upon the diameter to thickness ratio. A sensitivity analysis is also conducted to study the variations in the load and resistance factors due to changes in (a) coefficients of variation for pressure, moment, and ultimate stress, (b) ratio of mean design pressure to mean design moment, (c) distribution types used for characterizing the random variables, and (d) statistical correlation between random variables. It is observed that characterization of random variables by log-normal distribution is reasonable. Consideration of statistical correlation between the ultimate stress and section modulus gives higher values of the load factor for pressure but lower value for the moment than the corresponding values obtained by considering the variables to be uncorrelated. Since the effect of statistical correlation on the load and resistance factors is relatively insignificant for target reliability values of practical interest, the effect of correlated variables may be neglected

  17. Residential Load Manageability Factor Analyses by Load Sensitivity Affected by Temperature

    Directory of Open Access Journals (Sweden)

    N. Eskandari

    2016-12-01

    Full Text Available Load side management is the basic and significant principle to keeping the balance between generation side and consumption side of electrical power energy. Load side management on typical medium voltage feeder is the power energy consumption control of connected loads with variation of essential parameters that loads do reaction to their variation. Knowing amount of load's reaction to each parameters variation in typical medium voltage feeder during the day, leads to gain Load Manageability Factor (LMF for that specific feeder that helps power utilities to manage their connected loads. Calculating this LMF needs to find out each types of load with unique inherent features behavior to each parameters variation. This paper results and future work results will help us to catch mentioned LMF. In this paper analysis of residential load behavior due to temperature variation with training artificial neural network will be done. Load behavior due to other essential parameters variations like energy pricing variation, major event happening, and power utility announcing to the customers, and etc will study in future works. Collecting all related works results in a unit mathematical equation or an artificial neural network will gain LMF.

  18. Testing for time-varying loadings in dynamic factor models

    DEFF Research Database (Denmark)

    Mikkelsen, Jakob Guldbæk

    Abstract: In this paper we develop a test for time-varying factor loadings in factor models. The test is simple to compute and is constructed from estimated factors and residuals using the principal components estimator. The hypothesis is tested by regressing the squared residuals on the squared...... there is evidence of time-varying loadings on the risk factors underlying portfolio returns for around 80% of the portfolios....

  19. RIP INPUT TABLES FROM WAPDEG FOR LA DESIGN SELECTION: HIGHER THERMAL LOADING

    International Nuclear Information System (INIS)

    K. Mon

    1999-01-01

    The purpose of this calculation is to document (1) the Waste Package Degradation (WAPDEG) version 3.09 (CRWMS M and O 1998b. Software Routine Report for WAPDEG (Version 3.09)) simulations used to analyze waste package degradation and failure under the repository exposure conditions characterized by the higher thermal loading repository design feature and, (2) post-processing of these results into tables of waste package degradation time histories suitable for use as input into the Integrated Probabilistic Simulator for Environmental Systems version 5.19.01 (RIP) computer program (Golder Associates 1998). Specifically, the WAPDEG simulations discussed in this calculation correspond to waste package emplacement conditions (repository environment and design) defined in the Total System Performance Assessment-Viability Assessment (TSPA-VA), with the exception that the higher thermal loading Design Feature (Design Feature 26) of the License Application Design Selection (LADS) analysis was analyzed. Higher thermal loading would keep the drift temperature above the boiling point of water for a longer period of time, thereby minimizing moisture around the waste packages during a longer post-closure period. The higher thermal loading would also affect the surrounding rock, which may have adverse effects. The only failure mechanism of this feature would be if the effects on the surrounding rock were determined to be unacceptable. As a result of the change in waste package placement relative to the TSPA-VA base-case design, different temperature and relative humidity time histories at the waste package surface are calculated (input to the WAPDEG simulations), and consequently different waste package failure histories (as calculated by WAPDEG) result

  20. The use of simulated rainfall to study the discharge process and the influence factors of urban surface runoff pollution loads.

    Science.gov (United States)

    Qinqin, Li; Qiao, Chen; Jiancai, Deng; Weiping, Hu

    2015-01-01

    An understanding of the characteristics of pollutants on impervious surfaces is essential to estimate pollution loads and to design methods to minimize the impacts of pollutants on the environment. In this study, simulated rainfall equipment was constructed to investigate the pollutant discharge process and the influence factors of urban surface runoff (USR). The results indicated that concentrations of total suspended solids (TSS), total nitrogen (TN), total phosphorus (TP) and chemical oxygen demand (COD) appeared to be higher in the early period and then decreased gradually with rainfall duration until finally stabilized. The capacity and particle size of surface dust, rainfall intensity and urban surface slopes affected runoff pollution loads to a variable extent. The loads of TP, TN and COD showed a positive relationship with the surface dust capacity, whereas the maximum TSS load appeared when the surface dust was 0.0317 g·cm⁻². Smaller particle sizes (pollution carrying capacity of runoff, leading to higher pollution loads. Knowledge of the influence factors could assist in the management of USR pollution loads.

  1. Conservative flight with a varying load factor and closed form ...

    Indian Academy of Sciences (India)

    Conservative flight performance of an aircraft with constant load factor was analysed by ... Within the frame work of flat earth hypotheses the equations of motion of an aircraft as obtained by ..... load factor function if this inequality holds good.

  2. Reliability-Based Calibration of Load Duration Factors for Timber Structures

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Svensson, Staffan; Stang, Birgitte Friis Dela

    2005-01-01

    John Dalsgaard Sørensen, Staffan Svensson, Birgitte Dela Stang : Reliability-Based Calibration of Load Duration Factors for Timber Structures     Abstract :   The load bearing capacity of timber structures decrease with time depending on the type of load and timber. Based on representative limit...... states and stochastic models for timber structures, load duration factors are calibrated using probabilistic methods. Load duration e.ects are estimated on basis of simulation of realizations of wind, snow and imposed loads in accordance with the load models in the Danish structural codes. Three damage...... accumulation models are considered, namely Gerhards model, Barrett and Foschi _ s model and Foschi and Yao _ s model. The parameters in these models are .tted by the Maximum Likelihood Method using data relevant for Danish structural timber and the statistical uncertainty is quanti .ed. The reliability...

  3. Reducing Undue Conservatism in "Higher Frequency" Structural Design Loads in Aerospace Components

    Science.gov (United States)

    Knight, J. Brent

    2012-01-01

    This study is intended to investigate the frequency dependency of significant strain due to vibratory loads in aerospace vehicle components. The notion that "higher frequency" dynamic loads applied as static loads is inherently conservative is perceived as widely accepted. This effort is focused on demonstrating that principle and attempting to evolve methods to capitalize on it to mitigate undue conservatism. It has been suggested that observations of higher frequency modes that resulted in very low corresponding strain did so due to those modes not being significant. Two avionics boxes, one with its first significant mode at 341 Hz and the other at 857 Hz, were attached to a flat panel installed on a curved orthogrid panel which was driven acoustically in tests performed at NASA/MSFC. Strain and acceleration were measured at select locations on each of the boxes. When possible, strain gage rosettes and accelerometers were installed on either side of a given structural member so that measured strain and acceleration data would directly correspond to one another. Ultimately, a frequency above which vibratory loads can be disregarded for purposes of static structural analyses and sizing of typical robust aerospace components is sought.

  4. Loading factor and inclination parameter of diagonal type MHD generators

    International Nuclear Information System (INIS)

    Ishikawa, Motoo

    1979-01-01

    Regarding diagonal type MHD generators is studied the relation between the loading factor and inclination parameter which is required for attaining the maximum power density with a given electrical efficiency on the assumption of infinitely segmented electrodes. The average current density on electrodes is calculated against the Hall parameter, loading factor, and inclination parameter. The diagonal type generator is compared with Faraday type generator regarding the average current density. Decreasing the loading factor from inlet to outlet is appropriate to small size generators but increasing to large size generators. The inclination parameter had better decrease in both generators, being smaller for small generators than for large ones. The average current density on electrodes of diagonal type generators varies less with the loading factor than the Faraday type. In large size generators its value can become smaller compared with that of the Faraday type. (author)

  5. EFFECT OF FLIPPED LEARNING ON COGNITIVE LOAD: A HIGHER EDUCATION RESEARCH

    Directory of Open Access Journals (Sweden)

    Celal Karaca

    2017-01-01

    Full Text Available The purpose of this study is to determine the effect of the flipped learning method on the cognitive load of the students. The study was conducted with a sample of 160 people who were trained in Department of Mechanical Engineering for algorithms and programming courses at a higher education level. The study, which lasted for 8 weeks, has a semi-experimental design. A 9-point scale developed by Paas and Van Merrienboer (1993 was used for cognitive load measurements. At the end of the weekly courses, the scale was filled by the experimental and control groups. Independent sample t test was applied through SPSS 24 program to the obtained data. In both instances, the cognitive load in the experimental group in which the flipped learning method was applied was found to be lower than the cognitive load in the control group in which traditional face-to-face training was applied. As a result, it can be said that flipped learning, if well structured, is a method reducing cognitive load.

  6. Impact Study on Power Factor of Electrical Load in Power Distribution System

    International Nuclear Information System (INIS)

    Syirrazie Che Soh; Harzawardi Hasim; Ahmad Asraf, A.S.

    2014-01-01

    Low Power Factor of electrical loads cause high current is drawn from power supply. The impact of this circumstance is influenced by impedance of electrical load. Therefore, the key consideration of this study is how impedance of electrical loads influence power factor of electrical loads, and then power distribution as the whole. This study is important to evaluate the right action to mitigate low power factor effectively for electrical energy efficiency purpose. (author)

  7. Application of Fracture Mechanics to Specify the Proof Load Factor for Clamp Band Systems of Launch Vehicles

    Science.gov (United States)

    Singaravelu, J.; Sundaresan, S.; Nageswara Rao, B.

    2013-04-01

    This article presents a methodology for evaluation of the proof load factor (PLF) for clamp band system (CBS) made of M250 Maraging steel following fracture mechanics principles.CBS is most widely used as a structural element and as a separation system. Using Taguchi's design of experiments and the response surface method (RSM) the compact tension specimens were tested to establish an empirical relation for the failure load ( P max) in terms of the ultimate strength, width, thickness, and initial crack length. The test results of P max closely matched with the developed RSM empirical relation. Crack growth rates of the maraging steel in different environments were examined. Fracture strength (σf) of center surface cracks and through-crack tension specimens are evaluated utilizing the fracture toughness ( K IC). Stress induced in merman band at flight loading conditions is evaluated to estimate the higher load factor and PLF. Statistical safety factor and reliability assessments were made for the specified flaw sizes useful in the development of fracture control plan for CBS of launch vehicles.

  8. 14 CFR 25.527 - Hull and main float load factors.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hull and main float load factors. 25.527... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Structure Water Loads § 25.527 Hull and main... 1=empirical hull station weighing factor, in accordance with figure 2 of appendix B. (7) r x=ratio...

  9. Moving Aerospace Structural Design Practice to a Load and Resistance Factor Approach

    Science.gov (United States)

    Larsen, Curtis E.; Raju, Ivatury S.

    2016-01-01

    Aerospace structures are traditionally designed using the factor of safety (FOS) approach. The limit load on the structure is determined and the structure is then designed for FOS times the limit load - the ultimate load. Probabilistic approaches utilize distributions for loads and strengths. Failures are predicted to occur in the region of intersection of the two distributions. The load and resistance factor design (LRFD) approach judiciously combines these two approaches by intensive calibration studies on loads and strength to result in structures that are efficient and reliable. This paper discusses these three approaches.

  10. Perceptual load corresponds with factors known to influence visual search.

    Science.gov (United States)

    Roper, Zachary J J; Cosman, Joshua D; Vecera, Shaun P

    2013-10-01

    One account of the early versus late selection debate in attention proposes that perceptual load determines the locus of selection. Attention selects stimuli at a late processing level under low-load conditions but selects stimuli at an early level under high-load conditions. Despite the successes of perceptual load theory, a noncircular definition of perceptual load remains elusive. We investigated the factors that influence perceptual load by using manipulations that have been studied extensively in visual search, namely target-distractor similarity and distractor-distractor similarity. Consistent with previous work, search was most efficient when targets and distractors were dissimilar and the displays contained homogeneous distractors; search became less efficient when target-distractor similarity increased irrespective of display heterogeneity. Importantly, we used these same stimuli in a typical perceptual load task that measured attentional spillover to a task-irrelevant flanker. We found a strong correspondence between search efficiency and perceptual load; stimuli that generated efficient searches produced flanker interference effects, suggesting that such displays involved low perceptual load. Flanker interference effects were reduced in displays that produced less efficient searches. Furthermore, our results demonstrate that search difficulty, as measured by search intercept, has little bearing on perceptual load. We conclude that rather than be arbitrarily defined, perceptual load might be defined by well-characterized, continuous factors that influence visual search. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  11. Factor Analysis of the Aggregated Electric Vehicle Load Based on Data Mining

    Directory of Open Access Journals (Sweden)

    Yao Wang

    2012-06-01

    Full Text Available Electric vehicles (EVs and the related infrastructure are being developed rapidly. In order to evaluate the impact of factors on the aggregated EV load and to coordinate charging, a model is established to capture the relationship between the charging load and important factors based on data mining. The factors can be categorized as internal and external. The internal factors include the EV battery size, charging rate at different places, penetration of the charging infrastructure, and charging habits. The external factor is the time-of-use pricing (TOU policy. As a massive input data is necessary for data mining, an algorithm is implemented to generate a massive sample as input data which considers real-world travel patterns based on a historical travel dataset. With the input data, linear regression was used to build a linear model whose inputs were the internal factors. The impact of the internal factors on the EV load can be quantified by analyzing the sign, value, and temporal distribution of the model coefficients. The results showed that when no TOU policy is implemented, the rate of charging at home and range anxiety exerts the greatest influence on EV load. For the external factor, a support vector regression technique was used to build a relationship between the TOU policy and EV load. Then, an optimization model based on the relationship was proposed to devise a TOU policy that levels the load. The results suggest that implementing a TOU policy reduces the difference between the peak and valley loads remarkably.

  12. Partial safety factors for berthing velocity and loads on marine structures

    NARCIS (Netherlands)

    Roubos, A.A.; Peters, D.J.; Groenewegen, Leon; Steenbergen, R.

    2018-01-01

    Design methods for marine structures have evolved into load and resistance factor design, however existing partial safety factors related to berthing velocity and loads have not been verified and validated by measurement campaigns. In this study, field observations of modern seagoing vessels

  13. Importance of nuclear station load factor in applied ro energy policies

    International Nuclear Information System (INIS)

    Gomes, Daniel de Souza

    2015-01-01

    Load factor is the ration between the energy produced by a station and the energy it would have produced running at maximum power. The factor intends for all types of commercial reactors. Nuclear plants continuously provide over 11% of the world's electricity. The reactors for which data were available generated 618.7 TWh of electricity in 2014. Typical load factor was around 75% in worldwide during the first quarter of 2015. In this manner, it obtained from an average, three-monthly or yearly. The regular load factor of the reactors in operation was around 56% in 1970. While, in 1980's decade, we have an increase to 63%, the same situation occurred in next the decade and suffering increasing to 73%. Currently, the load factor reaches 78%. Accidents are seasonal factors, with the occurrence of reduction of power generation plants. In 2015 in January, there are over 437 operable commercial reactors in 31 countries, with over 377,728 MWe of full capacity. In Brazil, total capacity is 1901 MWe, with around 2.8% of electricity energy consumed. The primary objective of this study was to find a forecast model that express the evolution of the load factor in the next years. In recent years occur an extensive development of pressurized water reactors in Asia. The periodicity of seasonal effects on the performance of nuclear power plants due to aging. However, the impact of plant age depended on new technologies that allow the growth of the performance. The accident of Fukushima was an inflection point for energy policies. The event produced a trend that reduced the load in the world. (author)

  14. Assessment of Various Risk Factors for Success of Delayed and Immediate Loaded Dental Implants: A Retrospective Analysis.

    Science.gov (United States)

    Prasant, M C; Thukral, Rishi; Kumar, Sachin; Sadrani, Sannishth M; Baxi, Harsh; Shah, Aditi

    2016-10-01

    Ever since its introduction in 1977, a minimum of few months of period is required for osseointegration to take place after dental implant surgery. With the passage of time and advancements in the fields of dental implant, this healing period is getting smaller and smaller. Immediate loading of dental implants is becoming a very popular procedure in the recent time. Hence, we retrospectively analyzed the various risk factors for the failure of delayed and immediate loaded dental implants. In the present study, retrospective analysis of all the patients was done who underwent dental implant surgeries either by immediate loading procedure or by delayed loading procedures. All the patients were divided broadly into two groups with one group containing patients in which delayed loaded dental implants were placed while other consisted of patients in whom immediate loaded dental implants were placed. All the patients in whom follow-up records were missing and who had past medical history of any systemic diseases were excluded from the present study. Evaluation of associated possible risk factors was done by classifying the predictable factors as primary and secondary factors. All the results were analyzed by Statistical Package for the Social Sciences (SPSS) software. Kaplan-Meier survival analyses and chi-square test were used for assessment of level of significance. In delayed and immediate group of dental implants, mean age of the patients was 54.2 and 54.8 years respectively. Statistically significant results were obtained while comparing the clinical parameters of the dental implants in both the groups while demographic parameters showed nonsignificant correlation. Significant higher risk of dental implant failure is associated with immediate loaded dental implants. Tobacco smoking, shorter implant size, and other risk factors play a significant role in predicting the success and failure of dental implants. Delayed loaded dental implant placement should be preferred

  15. Anterior cruciate ligament injuries in soccer: Loading mechanisms, risk factors, and prevention programs

    Directory of Open Access Journals (Sweden)

    Boyi Dai

    2014-12-01

    Full Text Available Anterior cruciate ligament (ACL injuries are common in soccer. Understanding ACL loading mechanisms and risk factors for ACL injury is critical for designing effective prevention programs. The purpose of this review is to summarize the relevant literature on ACL loading mechanisms, ACL injury risk factors, and current ACL injury prevention programs for soccer players. Literature has shown that tibial anterior translation due to shear force at the proximal end of tibia is the primary ACL loading mechanism. No evidence has been found showing that knee valgus moment is the primary ACL loading mechanism. ACL loading mechanisms are largely ignored in previous studies on risk factors for ACL injury. Identified risk factors have little connections to ACL loading mechanisms. The results of studies on ACL injury prevention programs for soccer players are inconsistent. Current ACL injury prevention programs for soccer players are clinically ineffective due to low compliance. Future studies are urgently needed to identify risk factors for ACL injury in soccer that are connected to ACL loading mechanisms and have cause-and-effect relationships with injury rate, and to develop new prevention programs to improve compliance.

  16. A study on the load distribution factor in the perforated square plate with elastic support

    International Nuclear Information System (INIS)

    Lee, Y.S.; Yim, J.S.

    1993-01-01

    The load distribution factor in the perforated square plate supporting by angle shape legs under concentrated load acting at arbitrary points through elastic media is calculated. For the calculation the perforated plate was converted into an orthotropic plate using the method suggested by J.B. Mahoney. The deflection for the calculation of the load distribution factor was obtained from the auxiliary plate which was extended both sides of the plate and it was compared with the results from ANSYS calculation. With this deflection, the calculation of the load distribution factor was performed. The result shows that the load distribution factor at the periphery of the plate is larger than that of in the central location. This load distribution factor could be used for re-distribution of the applied load in more accurate analysis of the plate as well as in the analysis of the elastic media as the load factor. (author)

  17. Load Distribution Factors for Composite Multicell Box Girder Bridges

    Science.gov (United States)

    Tiwari, Sanjay; Bhargava, Pradeep

    2017-12-01

    Cellular steel section composite with a concrete deck is one of the most suitable superstructures in resisting torsional and warping effects induced by highway loading. This type of structure has inherently created new design problems for engineers in estimating its load distribution when subjected to moving vehicles. Indian Codes of Practice does not provide any specific guidelines for the design of straight composite concrete deck-steel multi-cell bridges. To meet the practical requirements arising during the design process, a simple design method is needed for straight composite multi-cell bridges in the form of load distribution factors for moment and shear. This work presents load distribution characteristics of straight composite multi-cell box girder bridges under IRC trains of loads.

  18. Surface water acidification and critical loads: exploring the F-factor

    Directory of Open Access Journals (Sweden)

    K. Bishop

    2009-11-01

    Full Text Available As acid deposition decreases, uncertainties in methods for calculating critical loads become more important when judgements have to be made about whether or not further emission reductions are needed. An important aspect of one type of model that has been used to calculate surface water critical loads is the empirical F-factor which estimates the degree to which acid deposition is neutralised before it reaches a lake at any particular point in time relative to the pre-industrial, steady-state water chemistry conditions.

    In this paper we will examine how well the empirical F-functions are able to estimate pre-industrial lake chemistry as lake chemistry changes during different phases of acidification and recovery. To accomplish this, we use the dynamic, process-oriented biogeochemical model SAFE to generate a plausible time series of annual runoff chemistry for ca. 140 Swedish catchments between 1800 and 2100. These annual hydrochemistry data are then used to generate empirical F-factors that are compared to the "actual" F-factor seen in the SAFE data for each lake and year in the time series. The dynamics of the F-factor as catchments acidify, and then recover are not widely recognised.

    Our results suggest that the F-factor approach worked best during the acidification phase when soil processes buffer incoming acidity. However, the empirical functions for estimating F from contemporary lake chemistry are not well suited to the recovery phase when the F-factor turns negative due to recovery processes in the soil. This happens when acid deposition has depleted the soil store of BC, and then acid deposition declines, reducing the leaching of base cations to levels below those in the pre-industrial era. An estimate of critical load from water chemistry during recovery and empirical F functions would therefore result in critical loads that are too low. Therefore, the empirical estimates of the F-factor are a significant source of

  19. What is the relationship between mental workload factors and cognitive load types?

    Science.gov (United States)

    Galy, Edith; Cariou, Magali; Mélan, Claudine

    2012-03-01

    The present study tested the hypothesis of an additive interaction between intrinsic, extraneous and germane cognitive load, by manipulating factors of mental workload assumed to have a specific effect on either type of cognitive load. The study of cognitive load factors and their interaction is essential if we are to improve workers' wellbeing and safety at work. High cognitive load requires the individual to allocate extra resources to entering information. It is thought that this demand for extra resources may reduce processing efficiency and performance. The present study tested the effects of three factors thought to act on either cognitive load type, i.e. task difficulty, time pressure and alertness in a working memory task. Results revealed additive effects of task difficulty and time pressure, and a modulation by alertness on behavioral, subjective and psychophysiological workload measures. Mental overload can be the result of a combination of task-related components, but its occurrence may also depend on subject-related characteristics, including alertness. Solutions designed to reduce incidents and accidents at work should consider work organization in addition to task constraints in so far that both these factors may interfere with mental workload. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Metasystem approach to increase the load factor FMS

    Directory of Open Access Journals (Sweden)

    Pishchukhin Alexandr

    2017-01-01

    Full Text Available The work is devoted to increasing the efficiency of using flexible manufacture systems (FMS by increasing the load factor. Unlike the well-known multi-agent approach to production management, we are investigating the addition of a metasystem level allowing flexible combination of the decentralized control method with centralization. The metasystem approach allows to reduce management to flexible switching of functioning technologies on the basis of the replacement rule, while describing FMS as a metasystem consisting of classification of the system analyst J. Klir from structured data systems. Production events are simulated in virtual space with the help of a multi-agent approach. At the same time, the number of requests from the waiting queue is chosen such that it becomes possible to optimize the loading of the FMS in the simplest case by the full-scan method, if the queue is not available, then the initiative of choice is provided to communications of agents-technologies and agents-equipments. Experimental studies were carried out on the FMS model including six pieces of equipment divided into three groups with a stream of six applications, each of which has a technological route of six operations each‥ The experimental results showed the consistency of the developed approach by increasing the load factor of the FMS.

  1. Serviceability design load factors and reliability assessments for reinforced concrete containment structures

    International Nuclear Information System (INIS)

    Han Bong Koo

    1998-01-01

    A reinforced concrete nuclear power plant containment structure is subjected to various random static and stochastic loads during its lifetime. Since these loads involve inherent randomness and other uncertainties, an appropriate probabilistic model for each load must be established in order to perform reliability analysis. The current ASME code for reinforced concrete containment structures are not based on probability concepts. The stochastic nature of natural hazard or accidental loads and the variations of material properties require a probabilistic approach for a rational assessment of structural safety and performance. The paper develops probability-based load factors for the limit state design of reinforced concrete containment structures. The purpose of constructing reinforced concrete containment structure is to protect against radioactive release, and so the use of a serviceability limit state against crack failure that can cause the emission of radioactive materials is suggested as a critical limit state for reinforced concrete containment structures. Load factors for the design of reinforced concrete containment structures are proposed and carried out the reliability assessments. (orig.)

  2. The effect of some ecological factors on the intestinal parasite loads ...

    Indian Academy of Sciences (India)

    Some ecological factors that might potentially influence intestinal parasite loads in the Asian elephant (Elephas maximus Linn.) were investigated in the Nilgiris, southern India. Fresh dung samples from identified animals were analysed, and the number of eggs/g of dung used as an index of parasite load. Comparisons ...

  3. System incremental cost calculations using the participation factor load-flow formulation

    International Nuclear Information System (INIS)

    Meisel, J.

    1993-01-01

    The load-flow problem is reformulated such that the use of a slack-bus generator is included only as a special case. This reformulation, known as the participation factor load-flow, includes a total mismatch variable and a defined participation vector, which, in general, distributes this mismatch to all system buses. The slack-bus constraint can still be obtained by defining a particular participation vector. In using the participation factor load-flow in the transpose Jacobian approach to the economic optimal dispatch problem, the paper shows that the value of the system-λ can be controlled such that this value represents the minimal incremental change in generation costs per unit change in system total demand with this demand distributed according to the specified participation vector. Methods using the conventional B-coefficient loss formulas or slack-bus load-flows give system-λ values whereby the unit change in demand must be placed on a fictitious single load-bus or on the slack-bus, respectively. Having a system-λ value which more accurately represents a proposed energy interchange between interconnected systems is very important in developing valid costs for each system. An extensive 28-bus, 8-generator system is included to illustrate these results

  4. A load factor based mean-variance analysis for fuel diversification

    Energy Technology Data Exchange (ETDEWEB)

    Gotham, Douglas; Preckel, Paul; Ruangpattana, Suriya [State Utility Forecasting Group, Purdue University, West Lafayette, IN (United States); Muthuraman, Kumar [McCombs School of Business, University of Texas, Austin, TX (United States); Rardin, Ronald [Department of Industrial Engineering, University of Arkansas, Fayetteville, AR (United States)

    2009-03-15

    Fuel diversification implies the selection of a mix of generation technologies for long-term electricity generation. The goal is to strike a good balance between reduced costs and reduced risk. The method of analysis that has been advocated and adopted for such studies is the mean-variance portfolio analysis pioneered by Markowitz (Markowitz, H., 1952. Portfolio selection. Journal of Finance 7(1) 77-91). However the standard mean-variance methodology, does not account for the ability of various fuels/technologies to adapt to varying loads. Such analysis often provides results that are easily dismissed by regulators and practitioners as unacceptable, since load cycles play critical roles in fuel selection. To account for such issues and still retain the convenience and elegance of the mean-variance approach, we propose a variant of the mean-variance analysis using the decomposition of the load into various types and utilizing the load factors of each load type. We also illustrate the approach using data for the state of Indiana and demonstrate the ability of the model in providing useful insights. (author)

  5. The analysis of loading losses from tank trucks

    Directory of Open Access Journals (Sweden)

    Jovanović Ana P.

    2006-01-01

    Full Text Available The quantity of loading losses, which are the primary source of evaporative emissions from tank cars and trucks was analyzed in this paper. Loading losses occur as organic vapors in "empty" cargo tanks are displaced to the atmosphere by the liquid being loaded into the tanks. Emissions from loading petroleum liquid were estimated using three methods: the API (American Petroleum Institute method, the VDI (Verein Deutscher Ingenieure -Association of German Engineers method and the Yugoslav Standard JUS B.HO.531 method. The mass of evaporative losses from loading operations is a function of the following parameters: the method of loading the cargo, the physical and chemical characteristics of the cargo and the ambient temperature during loading. Evaporation losses from the loading of motor gasoline (MB-95, BMB-95, MB-98 and MB-86 and diesel fuels (D-2, Euro D-2 were calculated. Losses on a monthly and annual basis were presented for an assumed amount of loaded cargo. It was estimated that the highest loading losses occur in the summer period because of high ambient daily temperatures and in the period of higher transporting levels. It should be pointed out that the loading losses of diesel fuel calculated using an empirical coefficient according to JUS B.HO.531 are significantly higher in comparison with the loading losses calculated using emission factors from the EPA and the VDI method. The gasoline loading losses calculated using emission factors derived from the three methods are similar.

  6. The Meaning of Higher-Order Factors in Reflective-Measurement Models

    Science.gov (United States)

    Eid, Michael; Koch, Tobias

    2014-01-01

    Higher-order factor analysis is a widely used approach for analyzing the structure of a multidimensional test. Whenever first-order factors are correlated researchers are tempted to apply a higher-order factor model. But is this reasonable? What do the higher-order factors measure? What is their meaning? Willoughby, Holochwost, Blanton, and Blair…

  7. Local load-sharing fiber bundle model in higher dimensions.

    Science.gov (United States)

    Sinha, Santanu; Kjellstadli, Jonas T; Hansen, Alex

    2015-08-01

    We consider the local load-sharing fiber bundle model in one to five dimensions. Depending on the breaking threshold distribution of the fibers, there is a transition where the fracture process becomes localized. In the localized phase, the model behaves as the invasion percolation model. The difference between the local load-sharing fiber bundle model and the equal load-sharing fiber bundle model vanishes with increasing dimensionality with the characteristics of a power law.

  8. Power factor improvement in three-phase networks with unbalanced inductive loads using the Roederstein ESTAmat RPR power factor controller

    Science.gov (United States)

    Diniş, C. M.; Cunţan, C. D.; Rob, R. O. S.; Popa, G. N.

    2018-01-01

    The paper presents the analysis of a power factor with capacitors banks, without series coils, used for improving power factor for a three-phase and single-phase inductive loads. In the experimental measurements, to improve the power factor, the Roederstein ESTAmat RPR power factor controller can command up to twelve capacitors banks, while experimenting using only six capacitors banks. Six delta capacitors banks with approximately equal reactive powers were used for experimentation. The experimental measurements were carried out with a three-phase power quality analyser which worked in three cases: a case without a controller with all capacitors banks permanently parallel connected with network, and two other cases with power factor controller (one with setting power factor at 0.92 and the other one at 1). When performing experiments with the power factor controller, a current transformer was used to measure the current on one phase (at a more charged or less loaded phase).

  9. An estimation of finger-tapping rates and load capacities and the effects of various factors.

    Science.gov (United States)

    Ekşioğlu, Mahmut; İşeri, Ali

    2015-06-01

    The aim of this study was to estimate the finger-tapping rates and finger load capacities of eight fingers (excluding thumbs) for a healthy adult population and investigate the effects of various factors on tapping rate. Finger-tapping rate, the total number of finger taps per unit of time, can be used as a design parameter of various products and also as a psychomotor test for evaluating patients with neurologic problems. A 1-min tapping task was performed by 148 participants with maximum volitional tempo for each of eight fingers. For each of the tapping tasks, the participant with the corresponding finger tapped the associated key in the standard position on the home row of a conventional keyboard for touch typing. The index and middle fingers were the fastest fingers for both hands, and little fingers the slowest. All dominant-hand fingers, except little finger, had higher tapping rates than the fastest finger of the nondominant hand. Tapping rate decreased with age and smokers tapped faster than nonsmokers. Tapping duration and exercise had also significant effect on tapping rate. Normative data of tapping rates and load capacities of eight fingers were estimated for the adult population. In designs of psychomotor tests that require the use of tapping rate or finger load capacity data, the effects of finger, age, smoking, and tapping duration need to be taken into account. The findings can be used for ergonomic designs requiring finger-tapping capacity and also as a reference in psychomotor tests. © 2015, Human Factors and Ergonomics Society.

  10. Assessment of vehicular live load and load factors for design of short-span bridges according to the new Egyptian Code

    Directory of Open Access Journals (Sweden)

    Hatem M. Seliem

    2015-04-01

    The study shows that concrete box-girders designed according to ECP-201:2012 and ECP-201:2003 using the ultimate limit state method yield almost the same demand. Despite the increase in the VLL of ECP-201:2012, and consequently the live load forces, concrete I-shaped girder bridges will be subjected to less total factored internal forces in comparison to ECP-201:2003 This is attributed to the interaction between the live to dead loads ratio and the load combinations. Design of composite steel plate girder bridges according to ECP-201:2012 using the allowable stress design method yields over designed sections.

  11. Experimental Investigations on Axially and Eccentrically Loaded Masonry Walls

    Science.gov (United States)

    Keshava, Mangala; Raghunath, Seshagiri Rao

    2017-12-01

    In India, un-reinforced masonry walls are often used as main structural components in load bearing structures. Indian code on masonry accounts the reduction in strength of walls by using stress reduction factors in its design philosophy. This code was introduced in 1987 and reaffirmed in 1995. The present study investigates the use of these factors for south Indian masonry. Also, with the gaining popularity in block work construction, the aim of this study was to find out the suitability of these factors given in the Indian code to block work masonry. Normally, the load carrying capacity of masonry walls can be assessed in three ways, namely, (1) tests on masonry constituents, (2) tests on masonry prisms and (3) tests on full-scale wall specimens. Tests on bricks/blocks, cement-sand mortar, brick/block masonry prisms and 14 full-scale brick/block masonry walls formed the experimental investigation. The behavior of the walls was investigated under varying slenderness and eccentricity ratios. Hollow concrete blocks normally used as in-fill masonry can be considered as load bearing elements as its load carrying capacity was found to be high when compared to conventional brick masonry. Higher slenderness and eccentricity ratios drastically reduced the strength capacity of south Indian brick masonry walls. The reduction in strength due to slenderness and eccentricity is presented in the form of stress reduction factors in the Indian code. These factors obtained through experiments on eccentrically loaded brick masonry walls was lower while that of brick/block masonry under axial loads was higher than the values indicated in the Indian code. Also the reduction in strength is different for brick and block work masonry thus indicating the need for separate stress reduction factors for these two masonry materials.

  12. A New V2G Control Strategy for Load Factor Improvement Using Smoothing Technique

    Directory of Open Access Journals (Sweden)

    CHANHOM, P.

    2017-08-01

    Full Text Available This paper proposes a new vehicle-to-grid (V2G control strategy for improving the load factor in the power network. To operate the proposed strategy, the available storage capacity of the PEVs’ batteries is considered as a battery energy storage system (BESS for charging and discharging an amount of power corresponding to the V2G power command. Due to the remarkable advantages of the technique so-called simple moving average, it is selected for applying in the proposed V2G control strategy. In this research, for investigating the load factor improvement, the essential data including the daily-load profiles with 7-day and 14-day periods are used for the 3 studied cases. These 3 studied cases present the power network with variation of the PEVs locations for describing the PEVs usage and charging or discharging behavior. The performance of the proposed strategy is simulated and verified by the MATPOWER software. The simulation results show that the load factors of the 3 studied cases are improved. Moreover, the encouragement of energy arbitrage for the PEVs owners is also discussed in this paper.

  13. Expression of muscle anabolic and metabolic factors in mechanically loaded MLO-Y4 osteocytes

    NARCIS (Netherlands)

    Juffer, P.; Jaspers, R.T.; Lips, P.; Bakker, A.D.; Klein-Nulend, J.

    2012-01-01

    Lack of physical activity results in muscle atrophy and bone loss, which can be counteracted by mechanical loading. Similar molecular signaling pathways are involved in the adaptation of muscle and bone mass to mechanical loading. Whether anabolic and metabolic factors regulating muscle mass, i.e.,

  14. Environmental load factors and system strength evaluation of offshore jacket platforms

    CERN Document Server

    Nizamani, Zafarullah

    2015-01-01

    This book presents a study for the determination of environmental load factors for Jacket Platforms in Malaysia and a methodology to determine the life extension of aging platforms. The simplified methods described here could be used for determining not only structural reliability but also safety factors. Its content is particularly interesting to design and maintenance engineers who are working in offshore or onshore industry.

  15. Higher harmonic imaging of tensile plastic deformation in loading and reloading processes by local resonance method

    International Nuclear Information System (INIS)

    Kawashima, Koichiro; Yasui, Hajime

    2015-01-01

    We have imaged plastically deformed region in a 5052 aluminum plate under tensile loading, unloading and reloading processes by using an immersion local resonance method. By transmitting large-amplitude burst wave of which frequency is a through-thickness resonant frequency of the plate, dislocation loops in plastic zone are forced to vibrate. The higher harmonic amplitude excited by the dislocation movement is mapped for the transducer position. The extension of plastic zone under monotonically increased loading, decrease in harmonic amplitude under unloading process and marked extension of plastic zone in reloading up to 0.4% plastic strain are clearly imaged. (author)

  16. New conceptual copper alloy bearing for diesel engine to achieve longer life under higher load; Diesel engine yo komen`atsu chojumyo jikuuke no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Tomikawa, T; Oshiro, H; Hashizume, K; Kamiya, S [Taiho Kogyo Co. Ltd., Aichi (Japan)

    1997-10-01

    Recently, the requirement like higher output, lower fuel consumption and cleaner exhaust gas for automotive engines has been increased. As a result, especially, higher bearing performance is required for diesel engine under a higher unit load and longer period. For this reason, we have developed the new conceptual copper alloy bearing to achieve higher performance under a higher unit load. This paper describes about the performance of this new bearing material. 3 refs., 12 figs., 5 tabs.

  17. Evaluation on the Effect of Load Follow Controller's Weighting Factors

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Keuk Jong; Lee, Jae Gon [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    there are several important physical effects that limit the possibilities of power variations in NPPs. Some major effects are moderator and xenon effect. Moderator effect is relation with moderator density change and xenon effect is relation with the concentration change of Xe-135 which could affect axial power shape. These effects are more significant with large magnitudes of power variations and they are considered as major disturbances at the aspect of control method. Due to the above physical effects, it is necessary to carefully change nuclear power considering power distribution change in the core. So, when nuclear plants are required to operate on load variation mode, we could control not only reactor power but also power distribution. Generally, power distribution is controlled by reactor operators who have enough experience, whereas reactor power is automatically controlled by automatic controllers. So, it is necessary to design an automatic controller that controls both reactor power and power distribution for frequent load following operation. Korea Hydro and Nuclear Power Co., LTD (KHNP) has been developing automatic load follow controller as a part of Advanced Power Reactor Plus (APR+) development. The developing controller is composed of three algorithms which could control reactor power and axial power shape. This paper aimed to evaluate the effect of the controller’s weighting factors. So, in this paper, we identify the meaning of the weighting factors and the controlled output weighting factors are selected among them. In this study, the effect of output weighting factors is analyzed. According to the simulation results, it is recommended that the weighting factor of power be between 200 and 400 and that of ASI be between 200 and 600. In the near future, based on the study, optimization of power and ASI weighting factors will be performed at the same time.

  18. Nerve growth factor loaded heparin/chitosan scaffolds for accelerating peripheral nerve regeneration.

    Science.gov (United States)

    Li, Guicai; Xiao, Qinzhi; Zhang, Luzhong; Zhao, Yahong; Yang, Yumin

    2017-09-01

    Artificial chitosan scaffolds have been widely investigated for peripheral nerve regeneration. However, the effect was not as good as that of autologous grafts and therefore could not meet the clinical requirement. In the present study, the nerve growth factor (NGF) loaded heparin/chitosan scaffolds were fabricated via electrostatic interaction for further improving nerve regeneration. The physicochemical properties including morphology, wettability and composition were measured. The heparin immobilization, NGF loading and release were quantitatively and qualitatively characterized, respectively. The effect of NGF loaded heparin/chitosan scaffolds on nerve regeneration was evaluated by Schwann cells culture for different periods. The results showed that the heparin immobilization and NGF loading did not cause the change of bulk properties of chitosan scaffolds except for morphology and wettability. The pre-immobilization of heparin in chitosan scaffolds could enhance the stability of subsequently loaded NGF. The NGF loaded heparin/chitosan scaffolds could obviously improve the attachment and proliferation of Schwann cells in vitro. More importantly, the NGF loaded heparin/chitosan scaffolds could effectively promote the morphology development of Schwann cells. The study may provide a useful experimental basis to design and develop artificial implants for peripheral nerve regeneration and other tissue regeneration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Experimental study on the potential of higher octane number fuels for low load partially premixed combustion

    NARCIS (Netherlands)

    Wang, S.; van der Waart, K.; Somers, B.; de Goey, P.

    2017-01-01

    The optimal fuel for partially premixed combustion (PPC) is considered to be a gasoline boiling range fuel with an octane number around 70. Higher octane number fuels are considered problematic with low load and idle conditions. In previous studies mostly the intake air temperature did not exceed 30

  20. technical note: technical note: on the correctness of load loss factor ...

    African Journals Online (AJOL)

    eobe

    Load Loss Factor (LLF) is a function of the estimate of the losses between the grid supply point and the consumers. estimate ... i.e. the ratio of average demand to peak demand, and using this ratio to determine an approximation to the. LLF via ...

  1. Influential Factors in Choosing Higher Education Institutions Among Students

    Directory of Open Access Journals (Sweden)

    Zlata Kastelic

    2017-05-01

    Full Text Available Purpose and Originality:The purpose of this article is to determine which factors are influential for students inchoosinga specific higher education institution. Method:By analyzing available literature and existing surveys, we gained in-depthknowledgeof key theoretical conceptsof the researched problem. The latter represents the basis on which we have designed our own research algorithm and conducted a proper survey. The purpose of the research was to analyze, which factors affect the most individuals to enroll in aspecific higher education institution, and to what extent our findings coincide with other studies’ findings. Results:The results showed a significant degree of correlation between factors that motivate foreign students to enrol in a higher education institution. Society:By knowing which areinfluential factors for students’ enrollment in HEIs the latterwill be able to recognize and satisfy needs and desires of potential students and subsequently design attractive studying programmes and thus equip them with knowledge in order to become competent individuals to successfully compete on labour market. Limitations/Future Research: Generalisation of results was limited due to the small size of the sample, and since all respondents came from only one Slovenian region. But since this is the first such surveyit represents a complex and remarkable preliminary study that can be upgradedand generate important contribution in understanding the key factors, which stimultae students for enrollment in higher education institutions.

  2. Analytical Dancoff factor evaluations for reactor designs loaded with TRISO particle fuel

    International Nuclear Information System (INIS)

    Ji, Wei; Liang, Chao; Pusateri, Elise N.

    2014-01-01

    Highlights: • The Dancoff factors for randomly distributed TRISO fuel particles are evaluated. • A new “dual-sphere” model is proposed to predict Dancoff factors. • The new model accurately accounts for the coating regions of fuel particles. • High accuracy is achieved over a broad range of design parameters. • The new model can be used to analyze reactors with double heterogeneity. - Abstract: A new mathematical model, the dual-sphere model, is proposed to analytically evaluate Dancoff factors of TRISO fuel kernels based on the chord method. The accurate evaluation of fuel kernel Dancoff factors is needed when one analyzes nuclear reactors loaded with TRISO particle fuel. In these reactor designs, fuel kernels are randomly distributed and shield each other, causing a shadowing effect. The Dancoff factor is a quantitative measure of this effect and is determined by the spatial distribution of fuel kernels. A TRISO fuel particle usually consists of four layers that form a coating region outside the fuel kernel. When fuel particles are loaded in the reactor, the spatial distribution of fuel kernels can be affected by the thickness of the coating region. Therefore, the coating region should be taken into account in the calculation of Dancoff factors. However, the previous model, the single-sphere model, assumes no coating regions in the Dancoff factor predictions. To address this model deficiency, the dual-sphere model is proposed by deriving a new chord length distribution function between two fuel kernels that explicitly accounts for coating regions. The new model is employed to derive analytical solutions of infinite medium, intra-fuel pebble and intra-fuel compact/pin Dancoff factors over a wide range of volume packing fractions of TRISO fuel particles, varying from 2% to 60%. Comparisons are made with the predictions from the single-sphere model and reference Monte Carlo simulations. A significant improvement of the accuracy, over the ranges of

  3. Using a latent variable model with non-constant factor loadings to examine PM2.5 constituents related to secondary inorganic aerosols.

    Science.gov (United States)

    Zhang, Zhenzhen; O'Neill, Marie S; Sánchez, Brisa N

    2016-04-01

    Factor analysis is a commonly used method of modelling correlated multivariate exposure data. Typically, the measurement model is assumed to have constant factor loadings. However, from our preliminary analyses of the Environmental Protection Agency's (EPA's) PM 2.5 fine speciation data, we have observed that the factor loadings for four constituents change considerably in stratified analyses. Since invariance of factor loadings is a prerequisite for valid comparison of the underlying latent variables, we propose a factor model that includes non-constant factor loadings that change over time and space using P-spline penalized with the generalized cross-validation (GCV) criterion. The model is implemented using the Expectation-Maximization (EM) algorithm and we select the multiple spline smoothing parameters by minimizing the GCV criterion with Newton's method during each iteration of the EM algorithm. The algorithm is applied to a one-factor model that includes four constituents. Through bootstrap confidence bands, we find that the factor loading for total nitrate changes across seasons and geographic regions.

  4. Relation of Adiponectin to Glucose Tolerance Status, Adiposity, and Cardiovascular Risk Factor Load

    Directory of Open Access Journals (Sweden)

    N. Wolfson

    2012-01-01

    Full Text Available Objective. Adiponectin has anti-atherogenic and anti-inflammatory properties. We investigated the influence of adiponectin on glucose tolerance status, adiposity and cardiovascular risk factors (CVRFs. Design and Patients. Study consisted of 107 subjects: 55 with normal glucose tolerance (NGT and 52 with impaired glucose regulation (IGR who were divided into two groups: 24 subjects with impaired fasting glucose (IFG Group and 28 patients with type 2 diabetes mellitus (DM Group. In additional analysis, study participants were divided into two groups, according to CVRFs: low and high risk. Measurements: Patients were evaluated for glucose, HbA1C, insulin, lipids, CRP, HOMA-IR and adiponectin. Measurements. Patients were evaluated for glucose, HbA1C, insulin, lipids, CRP, HOMA-IR and adiponectin. Results. Adiponectin was significantly higher in NGT group than in IFG (=0.003 and DM (=0.01 groups. Adiponectin was significantly, positively associated with HDL and inversely associated with glucose, HbA1c, ALT, AST, TG, HOMA-IR. Patients with higher CVRFs load have lesser adiponectin compared to patients with low cardiovascular risk <0.0001. Adiponectin was inversely associated with the number of risk factors (=−0.430, =0.0001. Conclusions. Circulating adiponectin was significantly lower in subjects with different degree of IGR compared to subjects with normal glucose homeostasis. Adiponectin was significantly lower in high risk group than low risk group and decreased concurrently with increased number of CVRFs.

  5. Structural load combinations

    International Nuclear Information System (INIS)

    Hwang, H.; Reich, M.; Ellingwood, B.; Shinozuka, M.

    1985-01-01

    This paper presents the latest results of the program entitled, ''Probability Based Load Combinations For Design of Category I Structures''. In FY 85, a probability-based reliability analysis method has been developed to evaluate safety of shear wall structures. The shear walls are analyzed using stick models with beam elements and may be subjected to dead load, live load and in-plane eqrthquake. Both shear and flexure limit states are defined analytically. The limit state probabilities can be evaluated on the basis of these limit states. Utilizing the reliability analysis method mentioned above, load combinations for the design of shear wall structures have been established. The proposed design criteria are in the load and resistance factor design (LRFD) format. In this study, the resistance factors for shear and flexure and load factors for dead and live loads are preassigned, while the load factor for SSE is determined for a specified target limit state probability of 1.0 x 10 -6 or 1.0 x 10 -5 during a lifetime of 40 years. 23 refs., 9 tabs

  6. Structural load combinations

    International Nuclear Information System (INIS)

    Hwang, H.; Reich, M.; Ellingwood, B.; Shinozuka, M.

    1986-01-01

    This paper presents the latest results of the program entitled, ''Probability Based Load Combinations For Design of Category I Structures''. In FY 85, a probability-based reliability analysis method has been developed to evaluate safety of shear wall structures. The shear walls are analyzed using stick models with beam elements and may be subjected to dead load, live load and in-plane earthquake. Both shear and flexure limit states are defined analytically. The limit state probabilities can be evaluated on the basis of these limit states. Utilizing the reliability analysis method mentioned above, load combinations for the design of shear wall structures have been established. The proposed design criteria are in the load and resistance factor design (LRFD) format. In this study, the resistance factors for shear and flexure and load factors for dead and live loads are preassigned, while the load factor for SSE is determined for a specified target limit state probability of 1.0 x 10 -6 or 1.0 x 10 -5 during a lifetime of 40 years

  7. The effect of load factor on fission product decay heat from discharged reactor fuel

    International Nuclear Information System (INIS)

    Davies, B.S.J.

    1978-07-01

    A sum-of-exponentials expression representing the decay heat power following a burst thermal irradiation of 235 U has been used to investigate the effect of load factor during irradiation on subsequent decay heat production. A sequence of random numbers was used to indicate reactor 'on' and 'off' periods for irradiations which continued for a total of 1500 days at power and were followed by 100 days cooling. It was found that for these conditions decay heat is almost proportional to load factor. Estimates of decay heat uncertainty arising from the random irradiation pattern are also given. (author)

  8. Expression of insulin-like growth factor I, insulin-like growth factor binding proteins, and collagen mRNA in mechanically loaded plantaris tendon

    DEFF Research Database (Denmark)

    Olesen, Jens L; Heinemeier, Katja M; Haddad, Fadia

    2006-01-01

    Insulin-like growth factor I (IGF-I) is known to exert an anabolic effect on tendon fibroblast production of collagen. IGF-I's regulation is complex and involves six different IGF binding proteins (IGFBPs). Of these, IGFBP-4 and -5 could potentially influence the effect of IGF-I in the tendon...... because they both are produced in fibroblast; however, the response of IGFBP-4 and -5 to mechanical loading and their role in IGF-I regulation in tendinous tissue are unknown. A splice variant of IGF-I, mechano-growth factor (MGF) is upregulated and known to be important for adaptation in loaded muscle....... However, it is not known whether MGF is expressed and upregulated in mechanically loaded tendon. This study examined the effect of mechanical load on tendon collagen mRNA in relation to changes in the IGF-I systems mRNA expression. Data were collected at 2, 4, 8 and 16 days after surgical removal...

  9. Load and resistance factor rating (LRFR) in New York State : volume II.

    Science.gov (United States)

    2011-09-01

    This report develops a Load and Resistance Factor Rating (NYS-LRFR) methodology : for New York bridges. The methodology is applicable for the rating of existing : bridges, the posting of under-strength bridges, and checking Permit trucks. The : propo...

  10. Load and resistance factor rating (LRFR) in New York State : volume I.

    Science.gov (United States)

    2011-09-01

    This report develops a Load and Resistance Factor Rating (NYS-LRFR) methodology : for New York bridges. The methodology is applicable for the rating of existing : bridges, the posting of under-strength bridges, and checking Permit trucks. The : propo...

  11. Resveratrol-Loaded Lipid Nanocarriers: Correlation between In Vitro Occlusion Factor and In Vivo Skin Hydrating Effect

    Directory of Open Access Journals (Sweden)

    Lucia Montenegro

    2017-12-01

    Full Text Available Lipid nanocarriers show occlusive properties that may be related to their ability to improve skin hydration. The aim of this work was to evaluate the relationship between in vitro occlusion factor and in vivo skin hydration for three types of lipid nanocarriers: nanoemulsions (NEs, solid lipid nanoparticles (SLNs and nanostructured lipid carriers (NLCs. These lipid nanocarriers were loaded with trans-resveratrol (RSV and incorporated in gel vehicles. In vitro occlusion factor was in the order SLNs > NLCs > NEs. Gels containing unloaded or RSV loaded lipid nanocarriers were applied on the back of a hand of 12 healthy volunteers twice a day for one week, recording skin hydration changes using the instrument Soft Plus. An increase of skin hydration was observed for all lipid nanocarriers (SLNs > NLCs > NEs. RSV loading into these nanocarriers did not affect in vitro and in vivo lipid nanocarriers effects. A linear relationship (r2 = 0.969 was observed between occlusion factor and in vivo increase of skin hydration. Therefore, the results of this study showed the feasibility of using the occlusion factor to predict in vivo skin hydration resulting from topical application of different lipid nanocarriers loading an active ingredient with no inherent hydrating activity.

  12. Dutch monitor on stress and physical load: risk factors, consequences, and preventive action.

    Science.gov (United States)

    Houtman, I L; Goudswaard, A; Dhondt, S; van der Grinten, M P; Hildebrandt, V H; van der Poel, E G

    1998-02-01

    Due to recent changes in legislation on occupational health and safety, a national monitor on stress and physical load was developed in The Netherlands to monitor (a) risks and consequences of stress and physical load at work, (b) preventive actions in companies to reduce these risks, and (c) organisational and environmental variables that facilitate preventive actions. Information was gathered from employers, employees, and employees' representatives. The monitor was used with a nationally representative sample of companies in industry, wholesale trade, and banking and finance, 782 companies in total. The information from the employees, aggregated at the company level, was not found to be correlated with that from the employer from the same companies. Although many employers do recognise risk factors for both physical load and stress as a problem they often seem to underestimate the problem when compared with employees or their representatives. This is particularly the case for psychosocial risk factors. Also, the perception of outcome measures, especially employers who consider emotional exhaustion to be work related, were fewer than the employees' representatives of the same organisation. Preventive measures on physical load are much more popular than measures against stress. It is the responsibility of the employer to take more preventive action of all kinds. They need to recognise risk factors as problems and health outcomes to be related to work. Employees of larger companies should participate with employers to consider effective measures, and more use should be made of support at branch level. For specific preventive measures, specific predictors emerged. Except for measures to prevent work stress, information from employees did not sufficiently contribute to the initiation of preventive measures in the workplace.

  13. Factor Analysis on Criteria Affecting Lean Retrofit for Energy Efficient Initiatives in Higher Learning Institution Buildings

    Directory of Open Access Journals (Sweden)

    Abidin Nur IzieAdiana

    2017-01-01

    Full Text Available The expansion of Higher Learning Institution (HLI is a global concerns on energy demand due to campus act like a small city. Intensive mode of operation of a building is correlated to the energy utilization. Improvement in the current energy efficiency is crucial effort to minimize the environmental effect through minimisation of energy in operation by retrofitting and upgrade the existing building system or components to be more efficient. Basically, there are three recommended steps for the improvement known as lean initiatives, green technology and clean energy in response to becoming zero energy solutions for building. The deliberation of this paper is aimed to highlight the criteria affecting in retrofitting of existing building in HLI with lean initiatives in order to achieve energy efficiency and reduction of energy comsumption. Attention is devoted to reviewing the lean energy retrofitting initiatives criteria for daylighting (side lighting, daylighting (skylight and glazing. The questionnaire survey was employed and distributed to the architects who has an expertise in green building design. Factor analysis was adopted as a method of analysis by using Principal Component with Varimax Rotation. The result is presented through summarizing the sub-criteria according to its importance with a factor loading 0.50 and above. The result found that majority of the criteria developed achieved the significant factor loading value and in accordance with the protocal of analysis. In conclusion the results from analysis of this paper assists the stakeholders in assessing the significant criteria based on the desired lean energy retrofitting initiatives and also provides a huge contribution for future planning improvement in existing buildings to become an energy efficient building.

  14. Mean Velocity vs. Mean Propulsive Velocity vs. Peak Velocity: Which Variable Determines Bench Press Relative Load With Higher Reliability?

    Science.gov (United States)

    García-Ramos, Amador; Pestaña-Melero, Francisco L; Pérez-Castilla, Alejandro; Rojas, Francisco J; Gregory Haff, G

    2018-05-01

    García-Ramos, A, Pestaña-Melero, FL, Pérez-Castilla, A, Rojas, FJ, and Haff, GG. Mean velocity vs. mean propulsive velocity vs. peak velocity: which variable determines bench press relative load with higher reliability? J Strength Cond Res 32(5): 1273-1279, 2018-This study aimed to compare between 3 velocity variables (mean velocity [MV], mean propulsive velocity [MPV], and peak velocity [PV]): (a) the linearity of the load-velocity relationship, (b) the accuracy of general regression equations to predict relative load (%1RM), and (c) the between-session reliability of the velocity attained at each percentage of the 1-repetition maximum (%1RM). The full load-velocity relationship of 30 men was evaluated by means of linear regression models in the concentric-only and eccentric-concentric bench press throw (BPT) variants performed with a Smith machine. The 2 sessions of each BPT variant were performed within the same week separated by 48-72 hours. The main findings were as follows: (a) the MV showed the strongest linearity of the load-velocity relationship (median r = 0.989 for concentric-only BPT and 0.993 for eccentric-concentric BPT), followed by MPV (median r = 0.983 for concentric-only BPT and 0.980 for eccentric-concentric BPT), and finally PV (median r = 0.974 for concentric-only BPT and 0.969 for eccentric-concentric BPT); (b) the accuracy of the general regression equations to predict relative load (%1RM) from movement velocity was higher for MV (SEE = 3.80-4.76%1RM) than for MPV (SEE = 4.91-5.56%1RM) and PV (SEE = 5.36-5.77%1RM); and (c) the PV showed the lowest within-subjects coefficient of variation (3.50%-3.87%), followed by MV (4.05%-4.93%), and finally MPV (5.11%-6.03%). Taken together, these results suggest that the MV could be the most appropriate variable for monitoring the relative load (%1RM) in the BPT exercise performed in a Smith machine.

  15. Higher School Marketing Strategy Formation: Classifying the Factors

    Directory of Open Access Journals (Sweden)

    N. K. Shemetova

    2012-01-01

    Full Text Available The paper deals with the main trends of higher school management strategy formation. The author specifies the educational changes in the modern information society determining the strategy options. For each professional training level the author denotes the set of strategic factors affecting the educational service consumers and, therefore, the effectiveness of the higher school marketing. The given factors are classified from the stand-points of the providers and consumers of educational service (enrollees, students, graduates and postgraduates. The research methods include the statistic analysis and general methods of scientific analysis, synthesis, induction, deduction, comparison, and classification. The author is convinced that the university management should develop the necessary prerequisites for raising the graduates’ competitiveness in the labor market, and stimulate the active marketing policies of the relating subdivisions and departments. In author’s opinion, the above classification of marketing strategy factors can be used as the system of values for educational service providers. 

  16. Development of reliability-based load and resistance factor design methods for piping

    International Nuclear Information System (INIS)

    Ayyub, Bilal M.; Hill, Ralph S. III; Balkey, Kenneth R.

    2003-01-01

    Current American Society of Mechanical Engineers (ASME) nuclear codes and standards rely primarily on deterministic and mechanistic approaches to design. The American Institute of Steel Construction and the American Concrete Institute, among other organizations, have incorporated probabilistic methodologies into their design codes. ASME nuclear codes and standards could benefit from developing a probabilistic, reliability-based, design methodology. This paper provides a plan to develop the technical basis for reliability-based, load and resistance factor design of ASME Section III, Class 2/3 piping for primary loading, i.e., pressure, deadweight and seismic. The plan provides a proof of concept in that LRFD can be used in the design of piping, and could achieve consistent reliability levels. Also, the results from future projects in this area could form the basis for code cases, and additional research for piping secondary loads. (author)

  17. Factors controlling strength of structures, and anticipated overstrength for seismic load conditions

    International Nuclear Information System (INIS)

    Singh, A.K.

    1985-01-01

    This paper discusses how the safe shutdown earthquake level, the ratio of operating basis earthquake to safe shutdown earthquake level, the shape of the earthquake spectra and the modeling of the structure affect the seismic overstrength of structures. The relationship between actual mean strength and the minimum specified strength of concrete and structural steel is also presented. The paper identifies which concrete and steel structures are generally sized for earthquake loads and which are generally sized for other factors, e.g., tornado missiles, loss of coolant accident pressure loads, equipment laydown loads and radiation shielding. The results of a study evaluating the mean ultimate capacity of a pressurized water reactor containment are presented to show that in terms of a ground motion, the seismic capacity may be four to five times the design safe shutdown earthquake level

  18. Safeguarding subcriticality during loading and shuffling operations in the higher density of the RSG-GAS's silicide core

    International Nuclear Information System (INIS)

    Sembiring, T.M.; Kuntoro, I.

    2003-01-01

    The core conversion program of the RSG-GAS reactor is to convert the all-oxide to all-silicide core. The silicide equilibrium core with fuel meat density of 3.55 gU cm -3 is an optimal core for RSG-GAS reactor and it can significantly increase the operation cycle length from 25 to 32 full power days. Nevertheless, the subcriticality of the shutdown core and the shutdown margin are lower than of the oxide core. Therefore, the deviation of subcriticality condition in the higher silicide core caused by the fuel loading and shuffling error should be reanalysed. The objective of this work is to analyse the sufficiency of the subcriticality condition of the shutdown core to face the worst condition caused by an error during loading and shuffling operations. The calculations were carried out using the 2-dimensional multigroup neutron diffusion code of Batan-FUEL. In the fuel handling error, the calculated results showed that the subcriticality condition of the shutdown higher density silicide equilibrium core of RSG-GAS can be maintained. Therefore, all fuel management steps are fixed in the present reactor operation manual can be applied in the higher silicide equilibrium core of RSG-GAS reactor. (author)

  19. Probability Based Evaluation of Vehicular Bridge Load using Weigh-in-Motion Data

    Directory of Open Access Journals (Sweden)

    Widi Nugraha

    2016-02-01

    Full Text Available Load and Resistance Factored Design (LRFD method for designing bridge in Indonesia have been implemented for more than 25 years. LRFD method treating loads and strengths variables as random variables with specific safety factors for different loads and strengths variables type. The nominal loads, load factors, reduction factors, and other criteria for bridge design code can be determined to meet the reliability criteria. Statistical data of weigh-in-motion (WIM vehicular loads measurement in Northern Java highway, Cikampek - Pamanukan, West Java (2011, used in as statistical loads variable. A 25 m simple span bridge with reinforced concrete T-girder is used as a model for structural analysis due to WIM measured and nominal vehicular load based on RSNI T-02-2005, with applied bending moment of girder as the output. The distribution fitting result of applied bending moment due to WIM measured vehicular loads is lognormal. The maximum bending moment due to RSNI T-02-2005 nominal vehicular load is 842.45 kN-m and has probability of exceedance of 5x10-5. It can be concluded, for this study, that the bridge designed using RSNI T-02-2005 is safely designed, since it has reliability index, β of 5.02, higher than target reliability, β ranging from 3.50 or 3.72.

  20. Evaluation of the Effect of Platelet-Released Growth Factor and Immediate Orthodontic Loading on the Removal Torque of Miniscrews.

    Science.gov (United States)

    Bayani, Shahin; Masoomi, Fatemeh; Aghaabbasi, Sharereh; Farsinejad, Alireza

    2016-01-01

    The purpose of this study was to evaluate the effect of platelet-released growth factor (PRGF) and immediate orthodontic forces on the removal torque of miniscrews. This study was conducted on three male dogs aged 6 to 8 months with a body weight of 17.6 to 18.4 kg. Sixty miniscrews were inserted in the posterior aspect of the femur. There were four groups, including loaded miniscrews with application of PRGF, unloaded miniscrews without application of PRGF, unloaded miniscrews with PRGF, and loaded miniscrews without PRGF. Twenty miniscrews were inserted in the femoral bone of one foot of each dog, including all the aforementioned subgroups. After 12 weeks, the miniscrews were removed by a removal torque tester device and measured in newton centimeters. The mean removal torque values in four groups of immediately loaded screws with PRGF, unloaded screws with PRGF, immediately loaded screws without PRGF, and unloaded screws without PRGF were 19.68, 21.74, 13.65, and 15.46 Ncm, respectively. It was shown that the mean removal torque value for the group with PRGF was significantly higher than that in the other groups (P = .0001). Although there was a tendency toward a decrease in removal torque value with immediate loading, it was not statistically significant (P = .21). According to the results of this study, applying PRGF with miniscrews increased their stability, but the delivery of immediate force on miniscrews had no effect on the miniscrews' stability.

  1. Psychosocial factors and mental work load: a reality perceived by nurses in intensive care units

    Directory of Open Access Journals (Sweden)

    Paula Ceballos-Vásquez

    2015-04-01

    Full Text Available OBJECTIVE: To analyse the perception of psychosocial factors and mental workload of nurses who work in intensive care units. It is hypothesised that nurses in these units could perceive psychosocial risks, manifesting in a high mental work load. The psychosocial dimension related to the position's cognitive demands is hypothesised to mostly explain mental work load. METHOD: Quantitative study, with a descriptive, cross-sectional, and comparative design. A total of 91% of the intensive care unit populations of three Chilean hospitals was surveyed, corresponding to 111 nurses. The instruments utilised included (A a biosociodemographic history questionnaire; (b the SUSESO-ISTAS 21 questionnaire; and (c the Mental Work Load Subjective Scale (ESCAM, in Spanish. RESULTS: In total, 64% and 57% of participants perceived high levels of exposure to the psychosocial risks Psychosocial demands and Double shift, respectively. In addition, a medium-high level of overall mental load was observed. Positive and significant correlations between some of the SUSESO-ISTAS 21 and ESCAM dimensions were obtained. Using a regression analysis, it was determined that three dimensions of the psychosocial risk questionnaire helped to explain 38% of the overall mental load. CONCLUSION: Intensive care unit nurses felt that inadequate psychosocial factors and mental work overload existed in several of the tested dimensions.

  2. Perceptual load in different regions of the visual scene and its relevance for driving.

    Science.gov (United States)

    Marciano, Hadas; Yeshurun, Yaffa

    2015-06-01

    The aim of this study was to better understand the role played by perceptual load, at both central and peripheral regions of the visual scene, in driving safety. Attention is a crucial factor in driving safety, and previous laboratory studies suggest that perceptual load is an important factor determining the efficiency of attentional selectivity. Yet, the effects of perceptual load on driving were never studied systematically. Using a driving simulator, we orthogonally manipulated the load levels at the road (central load) and its sides (peripheral load), while occasionally introducing critical events at one of these regions. Perceptual load affected driving performance at both regions of the visual scene. Critically, the effect was different for central versus peripheral load: Whereas load levels on the road mainly affected driving speed, load levels on its sides mainly affected the ability to detect critical events initiating from the roadsides. Moreover, higher levels of peripheral load impaired performance but mainly with low levels of central load, replicating findings with simple letter stimuli. Perceptual load has a considerable effect on driving, but the nature of this effect depends on the region of the visual scene at which the load is introduced. Given the observed importance of perceptual load, authors of future studies of driving safety should take it into account. Specifically, these findings suggest that our understanding of factors that may be relevant for driving safety would benefit from studying these factors under different levels of load at different regions of the visual scene. © 2014, Human Factors and Ergonomics Society.

  3. Determination of the usage factor of components after cyclic loading by means of high-resolution microstructural examination

    International Nuclear Information System (INIS)

    Seibold, A.; Scheibe, A.; Assmann, H.D.

    1991-01-01

    Materials subjected to cyclic loading experience a change in the microstructure which may affect the service life. Quantification of the microstructural changes and allocation of the microstructural condition to the corresponding point on the fatigue curve for the component material allows the usage factor to be derived. Taking the low-alloy, fine-grained structural steel 20MnMoNi55 (quenched and tempered structure) as an example, the relationship between microstructure and number of load cycles can be represented in the form of a reference curve. High-resolution examination allows the usage factor to be determined up to η=N/N f ≅0.5 under the given cyclic loading. Only a small specimen volume is required for examination using a transmission electron microscope. It can be taken from the component without affecting the required minimum wall thickness. The location of the specimen must, however, be stipulated, e.g. the location of highest loading according to calculations. When removing the specimen, care must be taken to ensure that the micro-structure is not affected. If these requirements are observed, high-resolution microstructural examination provides a method for checking the usage factor of a component. (orig.)

  4. Seismic Loading for FAST: May 2011 - August 2011

    Energy Technology Data Exchange (ETDEWEB)

    Asareh, M. A.; Prowell, I.

    2012-08-01

    As more wind farms are constructed in seismically active regions, earthquake loading increases in prominence for design and analysis of wind turbines. Early investigation of seismic load tended to simplify the rotor and nacelle as a lumped mass on top of the turbine tower. This simplification allowed the use of techniques developed for conventional civil structures, such as buildings, to be easily applied to wind turbines. However, interest is shifting to more detailed models that consider loads for turbine components other than the tower. These improved models offer three key capabilities in consideration of base shaking for turbines: 1) The inclusion of aerodynamics and turbine control; 2) The ability to consider component loads other than just tower loads; and 3) An improved representation of turbine response in higher modes by reducing modeling simplifications. Both experimental and numerical investigations have shown that, especially for large modern turbines, it is important to consider interaction between earthquake input, aerodynamics, and operational loads. These investigations further show that consideration of higher mode activity may be necessary in the analysis of the seismic response of turbines. Since the FAST code is already capable of considering these factors, modifications were developed that allow simulation of base shaking. This approach allows consideration of this additional load source within a framework, the FAST code that is already familiar to many researchers and practitioners.

  5. Load and resistance factor design of drilled shafts in shale for lateral loading.

    Science.gov (United States)

    2014-04-01

    A research project involving 32 drilled shaft load tests was undertaken to establish LRFD procedures for : design of drilled shafts subjected to lateral loads. Tests were performed at two Missouri Department of : Transportation (MoDOT) geotechnical r...

  6. Influence of overelastic loading on the stress intensity factor under thermal fatigue conditions

    International Nuclear Information System (INIS)

    Stamm, H.; Munz, D.

    1983-10-01

    Thermal shock loading often creates high thermal stresses which may exceed yield strength of the material in a surface layer. In this report the application of the linear elastic ΔK-concept in the case of cyclic thermal loading within the shakedown region is discussed. To this K-factors for an edge crack in a linear elastic - perfectly plastic plate are calculated using the weight function method and are compared with results obtained with the Finite Element Method. It is shown, that rearrangement stresses during plastic flow in the first cycle must be taken into account developing conservative approximation procedures. (orig.) [de

  7. Comparative limb bone loading in the humerus and femur of the tiger salamander: testing the 'mixed-chain' hypothesis for skeletal safety factors.

    Science.gov (United States)

    Kawano, Sandy M; Economy, D Ross; Kennedy, Marian S; Dean, Delphine; Blob, Richard W

    2016-02-01

    Locomotion imposes some of the highest loads upon the skeleton, and diverse bone designs have evolved to withstand these demands. Excessive loads can fatally injure organisms; however, bones have a margin of extra protection, called a 'safety factor' (SF), to accommodate loads that are higher than normal. The extent to which SFs might vary amongst an animal's limb bones is unclear. If the limbs are likened to a chain composed of bones as 'links', then similar SFs might be expected for all limb bones because failure of the system would be determined by the weakest link, and extra protection in other links could waste energetic resources. However, Alexander proposed that a 'mixed-chain' of SFs might be found amongst bones if: (1) their energetic costs differ, (2) some elements face variable demands, or (3) SFs are generally high. To test whether such conditions contribute to diversity in limb bone SFs, we compared the biomechanical properties and locomotor loading of the humerus and femur in the tiger salamander (Ambystoma tigrinum). Despite high SFs in salamanders and similar sizes of the humerus and femur that would suggest similar energetic costs, the humerus had lower bone stresses, higher mechanical hardness and larger SFs. SFs were greatest in the anatomical regions where yield stresses were highest in the humerus and lowest in the femur. Such intraspecific variation between and within bones may relate to their different biomechanical functions, providing insight into the emergence of novel locomotor capabilities during the invasion of land by tetrapods. © 2016. Published by The Company of Biologists Ltd.

  8. Elastic form factors at higher CEBAF energies

    Energy Technology Data Exchange (ETDEWEB)

    Petratos, G.G. [Kent State Univ., OH (United States)

    1994-04-01

    The prospects for elastic scattering from few body systems with higher beam energies at CEBAF is presented. The deuteron and{sup 3}He elastic structure functions A(Q{sup 2}) can be measured at sufficiently high momentum transfers to study the transition between the conventional meson-nucleon and the constituent quark-gluon descriptions. Possible improvements in the proton magnetic form factor data are also presented.

  9. Factors for Effective E-learning Integration in Higher Education in ...

    African Journals Online (AJOL)

    This article discusses factors that contribute to effective e-learning integration in higher education in the context of Sub-Sahara Africa. It involved retrieving articles using key words such as e-learning, perceptions, knowledge, skills, implementation, facilities, access, support, learning management system and higher ...

  10. Lipid-load in peripheral blood mononuclear cells: Impact of food-consumption, dietary-macronutrients, extracellular lipid availability and demographic factors.

    Science.gov (United States)

    Ameer, Fatima; Munir, Rimsha; Usman, Hina; Rashid, Rida; Shahjahan, Muhammad; Hasnain, Shahida; Zaidi, Nousheen

    2017-04-01

    Lipid-load in peripheral blood mononuclear cells (PBMCs) has recently gained attention of the researchers working on nutritional regulation of metabolic health. Previous works have indicated that the metabolic circuitries in the circulating PBMCs are influenced by dietary-intake and macronutrient composition of diet. In the present work, we analyzed the impact of diet and dietary macronutrients on PBMCs' lipid-load. The overall analyses revealed that dietary carbohydrates and fats combinatorially induce triglyceride accumulation in PBMCs. On the other hand, dietary fats were shown to induce significant decrease in PBMCs' cholesterol-load. The effects of various demographic factors -including age, gender and body-weight- on PBMCs' lipid-load were also examined. Body-weight and age were both shown to affect PBMC's lipid-load. Our study fails to provide any direct association between extracellular lipid availability and cholesterol-load in both, freshly isolated and cultured PBMCs. The presented work significantly contributes to the current understanding of the impact of food-consumption, dietary macronutrients, extracellular lipid availability and demographic factors on lipid-load in PBMCs. Copyright © 2017 Elsevier B.V. and Société Française de Biochimie et Biologie Moléculaire (SFBBM). All rights reserved.

  11. In Situ Loading of Basic Fibroblast Growth Factor Within Porous Silica Nanoparticles for a Prolonged Release

    Directory of Open Access Journals (Sweden)

    Postovit Lynne-Marie

    2009-01-01

    Full Text Available Abstract Basic fibroblast growth factor (bFGF, a protein, plays a key role in wound healing and blood vessel regeneration. However, bFGF is easily degraded in biologic systems. Mesoporous silica nanoparticles (MSNs with well-tailored porous structure have been used for hosting guest molecules for drug delivery. Here, we report an in situ route to load bFGF in MSNs for a prolonged release. The average diameter (d of bFGF-loaded MSNs is 57 ± 8 nm produced by a water-in-oil microemulsion method. The in vitro releasing profile of bFGF from MSNs in phosphate buffer saline has been monitored for 20 days through a colorimetric enzyme linked immunosorbent assay. The loading efficiency of bFGF in MSNs is estimated at 72.5 ± 3%. In addition, the cytotoxicity test indicates that the MSNs are not toxic, even at a concentration of 50 μg/mL. It is expected that the in situ loading method makes the MSNs a new delivery system to deliver protein drugs, e.g. growth factors, to help blood vessel regeneration and potentiate greater angiogenesis.

  12. Household crowding is associated with higher allostatic load among the Inuit.

    Science.gov (United States)

    Riva, Mylene; Plusquellec, Pierrich; Juster, Robert-Paul; Laouan-Sidi, Elhadji A; Abdous, Belkacem; Lucas, Michel; Dery, Serge; Dewailly, Eric

    2014-04-01

    Household crowding is an important problem in some aboriginal communities that is reaching particularly high levels among the circumpolar Inuit. Living in overcrowded conditions may endanger health via stress pathophysiology. This study examines whether higher household crowding is associated with stress-related physiological dysregulations among the Inuit. Cross-sectional data on 822 Inuit adults were taken from the 2004 Qanuippitaa? How are we? Nunavik Inuit Health Survey. Chronic stress was measured using the concept of allostatic load (AL) representing the multisystemic biological 'wear and tear' of chronic stress. A summary index of AL was constructed using 14 physiological indicators compiled into a traditional count-based index and a binary variable that contrasted people at risk on at least seven physiological indicators. Household crowding was measured using indicators of household size (total number of people and number of children per house) and overcrowding defined as more than one person per room. Data were analysed using weighted Generalised Estimating Equations controlling for participants' age, sex, income, diet and involvement in traditional activities. Higher household crowding was significantly associated with elevated AL levels and with greater odds of being at risk on at least seven physiological indicators, especially among women and independently of individuals' characteristics. This study demonstrates that household crowding is a source of chronic stress among the Inuit of Nunavik. Differential housing conditions are shown to be a marker of health inequalities among this population. Housing conditions are a critical public health issue in many aboriginal communities that must be investigated further to inform healthy and sustainable housing strategies.

  13. What does germane load mean? An empirical contribution to the cognitive load theory.

    Science.gov (United States)

    Debue, Nicolas; van de Leemput, Cécile

    2014-01-01

    While over the last decades, much attention has been paid to the mental workload in the field of human computer interactions, there is still a lack of consensus concerning the factors that generate it as well as the measurement methods that could reflect workload variations. Based on the multifactorial Cognitive Load Theory (CLT), our study aims to provide some food for thought about the subjective and objective measurement that can be used to disentangle the intrinsic, extraneous, and germane load. The purpose is to provide insight into the way cognitive load can explain how users' cognitive resources are allocated in the use of hypermedia, such as an online newspaper. A two-phase experiment has been conducted on the information retention from online news stories. Phase 1 (92 participants) examined the influence of multimedia content on performance as well as the relationships between cognitive loads and cognitive absorption. In Phase 2 (36 participants), eye-tracking data were collected in order to provide reliable and objective measures. Results confirmed that performance in information retention was impacted by the presence of multimedia content such as animations and pictures. The higher number of fixations on these animations suggests that users' attention could have been attracted by them. Results showed the expected opposite relationships between germane and extraneous load, a positive association between germane load and cognitive absorption and a non-linear association between intrinsic and germane load. The trends based on eye-tracking data analysis provide some interesting findings about the relationship between longer fixations, shorter saccades and cognitive load. Some issues are raised about the respective contribution of mean pupil diameter and Index of Cognitive Activity.

  14. Autotrophic and heterotrophic nitrification-anoxic denitrification dominated the anoxic/oxic sewage treatment process during optimization for higher loading rate and energy savings.

    Science.gov (United States)

    Zhang, Xueyu; Zheng, Shaokui; Zhang, Hangyu; Duan, Shoupeng

    2018-04-30

    This study clarified the dominant nitrogen (N)-transformation pathway and the key ammonia-oxidizing microbial species at three loading levels during optimization of the anoxic/oxic (A/O) process for sewage treatment. Comprehensive N-transformation activity analysis showed that ammonia oxidization was performed predominantly by aerobic chemolithotrophic and heterotrophic ammonia oxidization, whereas N 2 production was performed primarily by anoxic denitrification in the anoxic unit. The abundances of ammonia-oxidizing bacteria (AOB), nitrite-oxidizing bacteria, and anaerobic AOB in activated sludge reflected their activities on the basis of high-throughput sequencing data. AOB amoA gene clone libraries revealed that the predominant AOB species in sludge samples shifted from Nitrosomonas europaea (61% at the normal loading level) to Nitrosomonas oligotropha (58% and 81% at the two higher loading levels). Following isolation and sequencing, the predominant culturable heterotrophic AOB in sludge shifted from Agrobacterium tumefaciens (42% at the normal loading level) to Acinetobacter johnsonii (52% at the highest loading level). Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Spatial correction factors for YALINA Booster facility loaded with medium and low enriched fuels

    International Nuclear Information System (INIS)

    Talamo, A.; Gohar, Y.; Bournos, V.; Fokov, Y.; Kiyavitskaya, H.; Routkovskaya, C.

    2012-01-01

    The Bell and Glasstone spatial correction factor is used in analyses of subcritical assemblies to correct the experimental reactivity as function of the detector position. Besides the detector position, several other parameters affect the correction factor: the energy weighting function of the detector, the detector size, the energy-angle distribution of source neutrons, and the reactivity of the subcritical assembly. This work focuses on the dependency of the correction factor on the detector material and it investigates the YALINA Booster subcritical assembly loaded with medium (36%) and low (10%) enriched fuels. (authors)

  16. Spatial correction factors for YALINA Booster facility loaded with medium and low enriched fuels

    Energy Technology Data Exchange (ETDEWEB)

    Talamo, A.; Gohar, Y. [Argonne National Laboratory, 9700 S. Cass Ave, Argonne, IL 60439 (United States); Bournos, V.; Fokov, Y.; Kiyavitskaya, H.; Routkovskaya, C. [Joint Inst. for Power and Nuclear Research-Sosny, 99 Academician A.K.Krasin Str, Minsk 220109 (Belarus)

    2012-07-01

    The Bell and Glasstone spatial correction factor is used in analyses of subcritical assemblies to correct the experimental reactivity as function of the detector position. Besides the detector position, several other parameters affect the correction factor: the energy weighting function of the detector, the detector size, the energy-angle distribution of source neutrons, and the reactivity of the subcritical assembly. This work focuses on the dependency of the correction factor on the detector material and it investigates the YALINA Booster subcritical assembly loaded with medium (36%) and low (10%) enriched fuels. (authors)

  17. Peak load-impulse characterization of critical pulse loads in structural dynamics

    International Nuclear Information System (INIS)

    Abrahamson, G.R.; Lindberg, H.E.

    1975-01-01

    In presenting the characterization scheme, some general features are described first. A detailed analysis is given for the rigid-plastic system of one degree of freedom to illustrate the calculation of critical load curves in terms of peak load and impulse. This is followed by the presentation of critical load curves for uniformly loaded rigid-plastic beams and plates and for dynamic buckling of cylindrical shells under uniform lateral loads. The peak load-impulse characterization of critical pulse loads is compared with the dynamic load factor characterization, and some aspects of the history of the peak load-pulse scheme are presented. (orig./HP) [de

  18. Psychosocial risks evaluation factors: study with higher education teachers

    Directory of Open Access Journals (Sweden)

    Sara Lopes Borges

    2018-02-01

    Method: The study consisted of the administration of two instruments, one for the characterization of the sample and the other for assessing psychosocial risk factors — the Copenhagen Psychosocial Questionnaire — consisting of 76 items (5-point Likert scale, distributed in five dimensions, which measure indicators of exposure to psychosocial risks and their effects. Results: The study included 59 teachers, mostly men (50.8%, aged between 41 - 50 years (45.8%, with master's degree (59%, assistant professors (47.5%; with a stable employment relationship (68%, years of service between 14-17 years (18.7% and teaching between 11 - 17 hours a week (64.4%. The analysis of the various subscales revealed a psychosocial risk, showing that teachers are in a situation of vulnerability. There were significant differences between the risks experienced in public higher education and those experienced in private higher education. Gender, age, academic background, and professional category influenced the type of psychosocial risk. Conclusions: The study confirms the importance of the evaluation of psychosocial risk factors in the exercise of the teaching profession in higher education. It is recognized that it is necessary to assess and manage psychosocial risks in order to promote healthy working conditions, ensure respect and fair treatment, and encourage the promotion of work / family life balance, in order to minimize psychosocial risks and situations of vulnerability in higher education teachers.

  19. Locomotor loading mechanics in the hindlimbs of tegu lizards (Tupinambis merianae): comparative and evolutionary implications.

    Science.gov (United States)

    Sheffield, K Megan; Butcher, Michael T; Shugart, S Katherine; Gander, Jennifer C; Blob, Richard W

    2011-08-01

    Skeletal elements are usually able to withstand several times their usual load before they yield, and this ratio is known as the bone's safety factor. Limited studies on amphibians and non-avian reptiles have shown that they have much higher limb bone safety factors than birds and mammals. It has been hypothesized that this difference is related to the difference in posture between upright birds and mammals and sprawling ectotherms; however, limb bone loading data from a wider range of sprawling species are needed in order to determine whether the higher safety factors seen in amphibians and non-avian reptiles are ancestral or derived conditions. Tegus (family Teiidae) are an ideal lineage with which to expand sampling of limb bone loading mechanics for sprawling taxa, particularly for lizards, because they are from a different clade than previously sampled iguanas and exhibit different foraging and locomotor habits (actively foraging carnivore versus burst-activity herbivore). We evaluated the mechanics of locomotor loading for the femur of the Argentine black and white tegu (Tupinambus merianae) using three-dimensional measurements of the ground reaction force and hindlimb kinematics, in vivo bone strains and femoral mechanical properties. Peak bending stresses experienced by the femur were low (tensile: 10.4 ± 1.1 MPa; compressive: -17.4 ± 0.9 MPa) and comparable to those in other reptiles, with moderate shear stresses and strains also present. Analyses of peak femoral stresses and strains led to estimated safety factor ranges of 8.8-18.6 in bending and 7.8-17.5 in torsion, both substantially higher than typical for birds and mammals but similar to other sprawling tetrapods. These results broaden the range of reptilian and amphibian taxa in which high femoral safety factors have been evaluated and further indicate a trend for the independent evolution of lower limb bone safety factors in endothermic taxa.

  20. What does germane load mean? An empirical contribution to the cognitive load theory

    Directory of Open Access Journals (Sweden)

    Nicolas eDebue

    2014-10-01

    Full Text Available While over the last decades, much attention has been paid to the mental workload in the field of human computer interactions, there is still a lack of consensus concerning the factors that generate it as well as the measurement methods that could reflect workload variations. Based on the multifactorial Cognitive Load Theory, our study aims to provide some food for thought about the subjective and objective measurement that can be used to disentangle the intrinsic, extraneous and germane load. The purpose is to provide insight into the way cognitive load can explain how users’ cognitive resources are allocated in the use of hypermedia, such as an online newspaper. A two-phase experiment has been conducted on the information retention from online news stories. Phase 1 (92 participants examined the influence of multimedia content on performance as well as the relationships between cognitive loads and cognitive absorption. In Phase 2 (36 participants, eye-tracking data were collected in order to provide reliable and objective measures. Results confirmed that performance in information retention was impacted by the presence of multimedia content such as animations and pictures. The higher number of fixations on these animations suggests that users’ attention could have been attracted by them. Results showed the expected opposite relationships between Germane and Extraneous Load, a positive association between GL and cognitive absorption and a nonlinear association between Intrinsic and Germane Load. The trends based on eye-tracking data analysis provide some interesting findings about the relationships between longer fixations, shorter saccades and cognitive load. Some issues are raised about the respective contribution of mean pupil diameter and Index of Cognitive Activity.

  1. Low-back loading in lifting two loads beside the body compared to lifting one load in front of the body

    NARCIS (Netherlands)

    Faber, G.S.; Kingma, I.; Bakker, A.J.; van Dieen, J.H.

    2009-01-01

    Low-back load during manual lifting is considered an important risk factor for the occurrence of low-back pain. Splitting a load, so it can be lifted beside the body (one load in each hand), instead of in front of the body, can be expected to reduce low-back load. Twelve healthy young men lifted 10

  2. Shot loading platform analysis

    International Nuclear Information System (INIS)

    Norman, B.F.

    1994-01-01

    This document provides the wind/seismic analysis and evaluation for the shot loading platform. Hand calculations were used for the analysis. AISC and UBC load factors were used in this evaluation. The results show that the actual loads are under the allowable loads and all requirements are met

  3. Investigating the Effects of Loading Factors on the In Vitro Pharmaceutical Performance of Mesoporous Materials as Drug Carriers for Ibuprofen

    Directory of Open Access Journals (Sweden)

    Junmin Lai

    2017-02-01

    Full Text Available The aim of the study was to investigate the effects of the loading factors, i.e., the initial drug loading concentration and the ratio of the drug to carriers, on the in vitro pharmaceutical performance of drug-loaded mesoporous systems. Ibuprofen (IBU was used as a model drug, and two non-ordered mesoporous materials of commercial silica Syloid® 244FP (S244FP and Neusilin® US2 (NS2 were selected in the study. The IBU-loaded mesoporous samples were prepared by a solvent immersion method with a rotary evaporation drying technique and characterized by polarized light microscopy (PLM, Fourier transform infrared (FTIR spectroscopy, X-ray powder diffraction (XRPD and differential scanning calorimetry (DSC. Dissolution experiments were performed in simulated gastric media at 37 °C under non-sink conditions. The concentration of IBU in solution was determined by HPLC. The study showed that the dissolution rate of IBU can be improved significantly using the mesoporous S224FP carriers due to the conversion of crystalline IBU into the amorphous form. Both of the loading factors affected the IBU dissolution kinetics. Due to the molecular interaction between the IBU and NS2 carriers, the loading factors had little effects on the drug release kinetics with incomplete drug desorption recovery and insignificant dissolution enhancement. Care and extensive evaluation must therefore be taken when mesoporous materials are chosen as carrier delivery systems.

  4. Factors affecting the adoption and diffusion of Internet in higher ...

    African Journals Online (AJOL)

    Journal of Language, Technology & Entrepreneurship in Africa ... Factors affecting the adoption and diffusion of Internet in higher educational institutions in Kenya ... communication Technologies (ICTs) such as the Internet, Learning ...

  5. Edge loading in metal-on-metal hips: low clearance is a new risk factor.

    Science.gov (United States)

    Underwood, Richard J; Zografos, Angelos; Sayles, Ritchie S; Hart, Alister; Cann, Philippa

    2012-03-01

    The revision rate of large head metal-on-metal and resurfacing hips are significantly higher than conventional total hip replacements. The revision of these components has been linked to high wear caused by edge loading; which occurs when the head-cup contact patch extends over the cup rim. There are two current explanations for this; first, there is loss of entrainment of synovial fluid resulting in breakdown of the lubricating film and second, edge loading results in a large local increase in contact pressure and consequent film thickness reduction at the cup rim, which causes an increase in wear. This paper develops a method to calculate the distance between the joint reaction force vector and the cup rim--the contact patch centre to rim (CPCR) distance. However, the critical distance for the risk of edge loading is the distance from the contact patch edge to rim (CPER) distance. An analysis of explanted hip components, divided into edge worn and non-edge-worn components showed that there was no statistical difference in CPCR values, but the CPER value was significantly lower for edge worn hips. Low clearance hips, which have a more conformal contact, have a larger diameter contact patch and thus are more at risk of edge loading for similarly positioned hips.

  6. Historic Factors Influencing Korean Higher Education. Korean Studies Series, No. 17.

    Science.gov (United States)

    Jeong-kyu, Lee

    This book examines the religious and philosophical factors historically affecting Korean higher education, and the characteristics of contemporary Korean higher education in relation to organizational structure, leadership, and organizational culture. The book is organized into 4 parts, with 11 chapters. Part One focuses on identifying the problem…

  7. Field profile and loading measurements on higher order modes in a two cell 500 MHz superconducting structure

    International Nuclear Information System (INIS)

    Barry, W.; Edighoffer, J.; Chattopadhyay, S.; Fornaca, S.

    1992-08-01

    The Infrared Free Electron Laser, being designed at LBL as part of the Chemical Dynamics Research Laboratory, is based on a 500 MHz superconducting linac driver that consists of five 4-cell structures of the CERN/DESY type. A 500 MHz, 2-cell version of this structure is being used in a joint Stanford/LBL/BNL program to study accelerator issues relevant to the FEL applications. As part of this study, field profile and loading measurements of higher order modes have been made on the prototype structure

  8. A Market Segmentation Approach for Higher Education Based on Rational and Emotional Factors

    Science.gov (United States)

    Angulo, Fernando; Pergelova, Albena; Rialp, Josep

    2010-01-01

    Market segmentation is an important topic for higher education administrators and researchers. For segmenting the higher education market, we have to understand what factors are important for high school students in selecting a university. Extant literature has probed the importance of rational factors such as teaching staff, campus facilities,…

  9. Sustainable railway bridges with higher axle loads:monitoring examples from northern Sweden

    OpenAIRE

    Elfgren, Lennart; Enochsson, Ola; Täljsten, Björn; Paulsson, Björn

    2007-01-01

    Monitoring of several railway bridges has been carried out in northern Sweden in order to increase the allowable axle load. The work is part of a European Integrated Project "Sustainable Bridges - Assessment for Future Traffic Demands and Longer Lives". The paper describes the project and gives some examples of applications. Monitoring of several railway bridges has been carried out in northern Sweden in order to increase the allowable axle load. The work is part of a European Integrated P...

  10. Optimization of 10 kW solar photovoltaic – diesel generator hybrid energy system for different load factors at Jaisalmer location of Rajasthan, India

    Science.gov (United States)

    Saraswat, S. K.; Rao, K. V. S.

    2018-03-01

    Jaisalmer town in Rajasthan, India is having annual average solar insolation of 5.80 kWh/m2/day and 270 – 300 clear sky days in a year. A 10 kW off-grid hybrid energy system (HES) consisting of solar photovoltaic panels – diesel generator – bidirectional converter and batteries with zero percentage loss of load for Jaisalmer is designed using HOMER (version 3.4.3) software. Different system load factors of 0.33, 0.50, 0.67, 0.83 and 1 corresponding to fraction of running hours per day of the system are considered. The system is analyzed for all three aspects, namely, electrical, economic and emission point of view. Least levelized cost of electricity (LCOE) of Rs. 8.43/kWh is obtained at a load factor value of 0.5. If diesel generator alone (without Solar PV) is used to fulfil the demand for a load factor of 0.5the value of LCOE is obtained Rs.19.23/kWh. Comparison of results obtained for HES and diesel generator are made for load factor of 0.5 and 1.

  11. Load forecasting

    International Nuclear Information System (INIS)

    Mak, H.

    1995-01-01

    Slides used in a presentation at The Power of Change Conference in Vancouver, BC in April 1995 about the changing needs for load forecasting were presented. Technological innovations and population increase were said to be the prime driving forces behind the changing needs in load forecasting. Structural changes, market place changes, electricity supply planning changes, and changes in planning objectives were other factors discussed. It was concluded that load forecasting was a form of information gathering, that provided important market intelligence

  12. Effects on fatigue life of gate valves due to higher torque switch settings during operability testing

    International Nuclear Information System (INIS)

    Richins, W.D.; Snow, S.D.; Miller, G.K.; Russell, M.J.; Ware, A.G.

    1995-12-01

    Some motor operated valves now have higher torque switch settings due to regulatory requirements to ensure valve operability with appropriate margins at design basis conditions. Verifying operability with these settings imposes higher stem loads during periodic inservice testing. These higher test loads increase stresses in the various valve internal parts which may in turn increase the fatigue usage factors. This increased fatigue is judged to be a concern primarily in the valve disks, seats, yokes, stems, and stem nuts. Although the motor operators may also have significantly increased loading, they are being evaluated by the manufacturers and are beyond the scope of this study. Two gate valves representative of both relatively weak and strong valves commonly used in commercial nuclear applications were selected for fatigue analyses. Detailed dimensional and test data were available for both valves from previous studies at the Idaho National Engineering Laboratory. Finite element models were developed to estimate maximum stresses in the internal parts of the valves and to identity the critical areas within the valves where fatigue may be a concern. Loads were estimated using industry standard equations for calculating torque switch settings prior and subsequent to the testing requirements of USNRC Generic Letter 89--10. Test data were used to determine both; (1) the overshoot load between torque switch trip and final seating of the disk during valve closing and (2) the stem thrust required to open the valves. The ranges of peak stresses thus determined were then used to estimate the increase in the fatigue usage factors due to the higher stem thrust loads. The usages that would be accumulated by 100 base cycles plus one or eight test cycles per year over 40 and 60 years of operation were calculated

  13. Field profile and loading measurements on higher order modes in a two cell 500 MHz superconducting structure

    International Nuclear Information System (INIS)

    Barry, W.; Edighoffer, J.; Chattopadhyay, S.; Fornaco, S.

    1992-01-01

    The Infrared Free Electron Laser, being designed at LBL as part of the Chemical Dynamics Research Laboratory, is based on a 500 MHz superconducting linac driver that consists of five 4-cell structures of the CERN/DESY type. A 500 MHz, 2-cell version of this structure is being used in a joint Stanford/LBL/BNL program to study accelerator issues relevant to the FEL applications. As part of this study, field profile and loading measurements of higher order modes have been made on the prototype structure. (Author) 3 refs., 2 figs., tab

  14. Dynamic Regression Intervention Modeling for the Malaysian Daily Load

    Directory of Open Access Journals (Sweden)

    Fadhilah Abdrazak

    2014-05-01

    Full Text Available Malaysia is a unique country due to having both fixed and moving holidays.  These moving holidays may overlap with other fixed holidays and therefore, increase the complexity of the load forecasting activities. The errors due to holidays’ effects in the load forecasting are known to be higher than other factors.  If these effects can be estimated and removed, the behavior of the series could be better viewed.  Thus, the aim of this paper is to improve the forecasting errors by using a dynamic regression model with intervention analysis.   Based on the linear transfer function method, a daily load model consists of either peak or average is developed.  The developed model outperformed the seasonal ARIMA model in estimating the fixed and moving holidays’ effects and achieved a smaller Mean Absolute Percentage Error (MAPE in load forecast.

  15. General Factor Loadings and Specific Effects of the Differential Ability Scales, Second Edition Composites

    Science.gov (United States)

    Maynard, Jennifer L.; Floyd, Randy G.; Acklie, Teresa J.; Houston, Lawrence, III

    2011-01-01

    The purpose of this study was to investigate the "g" loadings and specific effects of the core and diagnostic composite scores from the Differential Abilities Scales, Second Edition (DAS-II; Elliott, 2007a). Scores from a subset of the DAS-II standardization sample for ages 3:6 to 17:11 were submitted to principal factor analysis. Four…

  16. John Carroll’s Views on Intelligence: Bi-Factor vs. Higher-Order Models

    Directory of Open Access Journals (Sweden)

    A. Alexander Beaujean

    2015-10-01

    Full Text Available The development of factor models is inextricably tied to the history of intelligence research. One of the most commonly-cited scholars in the field is John Carroll, whose three-stratum theory of cognitive ability has been one of the most influential models of cognitive ability in the past 20 years. Nonetheless, there is disagreement about how Carroll conceptualized the factors in his model. Some argue that his model is best represented through a higher-order model, while others argue that a bi-factor model is a better representation. Carroll was explicit about what he perceived the best way to represent his model, but his writings are not always easy to understand. In this article, I clarify his position by first describing the details and implications of bi-factor and higher-order models then show that Carroll’s published views are better represented by a bi-factor model.

  17. Effect of Loads and Other Key Factors on Oil-Transformer Ageing: Sustainability Benefits and Challenges

    Directory of Open Access Journals (Sweden)

    Radu Godina

    2015-10-01

    Full Text Available Transformers are one of the more expensive pieces of equipment found in a distribution network. The transformer’s role has not changed over the last decades. With simple construction and at the same time mechanically robust, they offer long term service that on average can reach half a century. Today, with the ongoing trend to supply a growing number of non-linear loads along with the notion of distributed generation (DG, a new challenge has arisen in terms of transformer sustainability, with one of the possible consequences being accelerated ageing. In this paper we carefully review the existing studies in the literature of the effect of loads and other key factors on oil-transformer ageing. The state-of-the-art is reviewed, each factor is analysed in detail, and in the end a smart transformer protection method is sought in order to monitor and protect it from upcoming challenges.

  18. Determination of Actual Friction Factors in Metal Forming under Heavy Loaded Regimes Combining Experimental and Numerical Analysis

    Science.gov (United States)

    Camacho, Ana María; Veganzones, Mariano; Claver, Juan; Martín, Francisco; Sevilla, Lorenzo; Sebastián, Miguel Ángel

    2016-01-01

    Tribological conditions can change drastically during heavy loaded regimes as experienced in metal forming; this is especially critical when lubrication can only be applied at the early stage of the process because the homogeneous lubricant layer can break along the die-workpiece interface. In these cases, adopting a constant friction factor for the lubricant-surface pair may not be a valid assumption. This paper presents a procedure based on the use of dual friction factor maps to determine friction factors employed in heavy loaded regimes. A finite element (FE) simulation is used to obtain the friction factor map for the alloy UNS A96082. Experiments were conducted using four lubricants (aluminum anti-size, MoS2 grease, silicone oil, and copper paste) to determine the actual friction curves. The experimental procedure is based on the application of lubricant only at the beginning of the first stage of ring compression, and not at intermediate stages as is usual in typical ring compression tests (RCTs). The results show that for small reductions (rh 20%), it is recommended to obtain an average value of the friction factor for every lubricant-surface pair in the range of deformation considered. PMID:28773868

  19. Analysis of bus passenger comfort perception based on passenger load factor and in-vehicle time.

    Science.gov (United States)

    Shen, Xianghao; Feng, Shumin; Li, Zhenning; Hu, Baoyu

    2016-01-01

    Although bus comfort is a crucial indicator of service quality, existing studies tend to focus on passenger load and ignore in-vehicle time, which can also affect passengers' comfort perception. Therefore, by conducting surveys, this study examines passengers' comfort perception while accounting for both factors. Then, using the survey data, it performs a two-way analysis of variance and shows that both in-vehicle time and passenger load significantly affect passenger comfort. Then, a bus comfort model is proposed to evaluate comfort level, followed by a sensitivity analysis. The method introduced in this study has theoretical implications for bus operators attempting to improve bus service quality.

  20. The impact of cognitive load on reward evaluation.

    Science.gov (United States)

    Krigolson, Olave E; Hassall, Cameron D; Satel, Jason; Klein, Raymond M

    2015-11-19

    The neural systems that afford our ability to evaluate rewards and punishments are impacted by a variety of external factors. Here, we demonstrate that increased cognitive load reduces the functional efficacy of a reward processing system within the human medial-frontal cortex. In our paradigm, two groups of participants used performance feedback to estimate the exact duration of one second while electroencephalographic (EEG) data was recorded. Prior to performing the time estimation task, both groups were instructed to keep their eyes still and avoid blinking in line with well established EEG protocol. However, during performance of the time-estimation task, one of the two groups was provided with trial-to-trial-feedback about their performance on the time-estimation task and their eye movements to induce a higher level of cognitive load relative to participants in the other group who were solely provided with feedback about the accuracy of their temporal estimates. In line with previous work, we found that the higher level of cognitive load reduced the amplitude of the feedback-related negativity, a component of the human event-related brain potential associated with reward evaluation within the medial-frontal cortex. Importantly, our results provide further support that increased cognitive load reduces the functional efficacy of a neural system associated with reward processing. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Lateral loadings on snubber assemblies

    International Nuclear Information System (INIS)

    Raphael, L.S.

    1981-01-01

    This paper examines the installation of snubber assemblies in power plants with respect to transverse or lateral loads as well as axial loads. Evaluation of the effects of low level, lateral loads was performed by analytical means. At higher loadings, the snubber assembly could no longer be treated as a column; therefore, the effects of lateral loadings was determined by test. The test consisted of applying both lateral and axial loads simultaneously. Results of both the analysis and the test showed that the application of lateral loads had a considerable effect on the snubber assemblies

  2. Load theory behind the wheel; perceptual and cognitive load effects.

    Science.gov (United States)

    Murphy, Gillian; Greene, Ciara M

    2017-09-01

    Perceptual Load Theory has been proposed as a resolution to the longstanding early versus late selection debate in cognitive psychology. There is much evidence in support of Load Theory but very few applied studies, despite the potential for the model to shed light on everyday attention and distraction. Using a driving simulator, the effect of perceptual and cognitive load on drivers' visual search was assessed. The findings were largely in line with Load Theory, with reduced distractor processing under high perceptual load, but increased distractor processing under high cognitive load. The effect of load on driving behaviour was also analysed, with significant differences in driving behaviour under perceptual and cognitive load. In addition, the effect of perceptual load on drivers' levels of awareness was investigated. High perceptual load significantly increased inattentional blindness and deafness, for stimuli that were both relevant and irrelevant to driving. High perceptual load also increased RTs to hazards. The current study helps to advance Load Theory by illustrating its usefulness outside of traditional paradigms. There are also applied implications for driver safety and roadway design, as the current study suggests that perceptual and cognitive load are important factors in driver attention. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  3. Allostatic Load and Effort-Reward Imbalance: Associations over the Working-Career.

    Science.gov (United States)

    Coronado, José Ignacio Cuitún; Chandola, Tarani; Steptoe, Andrew

    2018-01-24

    Although associations between work stressors and stress-related biomarkers have been reported in cross-sectional studies, the use of single time measurements of work stressors could be one of the reasons for inconsistent associations. This study examines whether repeated reports of work stress towards the end of the working career predicts allostatic load, a measure of chronic stress related physiological processes. Data from waves 2 to 6 of the English Longitudinal Study of Ageing (ELSA) were analysed, with a main analytical sample of 2663 older adults (aged 50+) who had at least one measurement of effort-reward imbalance between waves 2-6 and a measurement of allostatic load at wave 6. Cumulative work stress over waves 2-6 were measured by the effort-reward imbalance model. ELSA respondents who had reported two or more occasions of imbalance had a higher (0.3) estimate of the allostatic load index than those who did not report any imbalance, controlling for a range of health and socio-demographic factors, as well as allostatic load at baseline. More recent reports of imbalance were significantly associated with a higher allostatic load index, whereas reports of imbalance from earlier waves of ELSA were not. The accumulation of work related stressors could have adverse effects on chronic stress biological processes.

  4. An exact model for airline flight network optimization based on transport momentum and aircraft load factor

    Directory of Open Access Journals (Sweden)

    Daniel Jorge Caetano

    2017-12-01

    Full Text Available The problem of airline flight network optimization can be split into subproblems such as Schedule Generation (SG and Fleet Assignment (FA, solved in consecutive steps or in an integrated way, usually based on monetary costs and revenue forecasts. A linear pro­gramming model to solve SG and FA in an integrated way is presented, but with an al­ternative approach based on transport momentum and aircraft load factor. This alterna­tive approach relies on demand forecast and allows obtaining solutions considering min­imum average load factors. Results of the proposed model applications to instances of a regional Brazilian airline are presented. The comparison of the schedules generated by the proposed approach against those obtained by applying a model based on mone­tary costs and revenue forecasts demonstrates the validity of this alternative approach for airlines network planning.

  5. The prediction of the impact of climatic factors on short-term electric power load based on the big data of smart city

    Science.gov (United States)

    Qiu, Yunfei; Li, Xizhong; Zheng, Wei; Hu, Qinghe; Wei, Zhanmeng; Yue, Yaqin

    2017-08-01

    The climate changes have great impact on the residents’ electricity consumption, so the study on the impact of climatic factors on electric power load is of significance. In this paper, the effects of the data of temperature, rainfall and wind of smart city on short-term power load is studied to predict power load. The authors studied the relation between power load and daily temperature, rainfall and wind in the 31 days of January of one year. In the research, the authors used the Matlab neural network toolbox to establish the combinational forecasting model. The authors trained the original input data continuously to get the internal rules inside the data and used the rules to predict the daily power load in the next January. The prediction method relies on the accuracy of weather forecasting. If the weather forecasting is different from the actual weather, we need to correct the climatic factors to ensure accurate prediction.

  6. Intelligence Tests with Higher G-Loadings Show Higher Correlations with Body Symmetry: Evidence for a General Fitness Factor Mediated by Developmental Stability

    Science.gov (United States)

    Prokosch, M.D.; Yeo, R.A.; Miller, G.F.

    2005-01-01

    Just as body symmetry reveals developmental stability at the morphological level, general intelligence may reveal developmental stability at the level of brain development and cognitive functioning. These two forms of developmental stability may overlap by tapping into a ''general fitness factor.'' If so, then intellectual tests with higher…

  7. Stress-intensity factors for cracks emanating from the loaded fastener hole

    Science.gov (United States)

    Shivakumar, V.; Hsu, Y. C.

    1977-01-01

    Using a series approach and the Muskhelishvili formulation in the two-dimensional theory of elasticity, stress-intensity factors K are derived for problems in which cracks emanate radially from the boundary of an arbitrarily loaded internal circular hole in an infinite plate. Numerical values are obtained for K(I) and K(II) for radial cracks from a hole containing a loose-fitted pin or rivet that is pulled perpendicular to the crack direction in the plane of the plate. The method is a general one for determining K for a set of symmetrically emanating radial cracks for a variety of concentrated or distributed tractions on the circular hole.

  8. Cognitive Load and Cooperation

    DEFF Research Database (Denmark)

    Døssing, Felix Sebastian; Piovesan, Marco; Wengström, Erik Roland

    2017-01-01

    We study the effect of intuitive and reflective processes on cooperation using cognitive load. Compared with time constraint, which has been used in the previous literature, cognitive load is a more direct way to block reflective processes, and thus a more suitable way to study the link between...... intuition and cooperation. Using a repeated public goods game, we study the effect of different levels of cognitive load on contributions. We show that a higher cognitive load increases the initial level of cooperation. In particular, subjects are significantly less likely to fully free ride under high...... cognitive load....

  9. Performance study of Ke factors in simplified elastic plastic fatigue analyses with emphasis on thermal cyclic loading

    International Nuclear Information System (INIS)

    Lang, Hermann; Rudolph, Juergen; Ziegler, Rainer

    2011-01-01

    As code-based fully elastic plastic code conforming fatigue analyses are still time consuming, simplified elastic plastic analysis is often applied. This procedure is known to be overly conservative for some conditions due to the applied plastification (penalty) factor K e . As a consequence, less conservative fully elastic plastic fatigue analyses based on non-linear finite element analyses (FEA) or simplified elastic plastic analysis based on more realistic K e factors have to be used for fatigue design. The demand for more realistic K e factors is covered as a requirement of practical fatigue analysis. Different code-based K e procedures are reviewed in this paper with special regard to performance under thermal cyclic loading conditions. Other approximation formulae such as those by Neuber, Seeger/Beste or Kuehnapfel are not evaluated in this context because of their applicability to mechanical loading excluding thermal cyclic loading conditions typical for power plant operation. Besides the current code-based K e corrections, the ASME Code Case N-779 (e.g. Adam's proposal) and its modification in ASME Section VIII is considered. Comparison of elastic plastic results and results from the Rules for Nuclear Facility Components and Rules for Pressure Vessels reveals a considerable overestimation of usage factor in the case of ASME III and KTA 3201.2 for the examined examples. Usage factors according to RCC-M, Adams (ASME Code Case N-779), ASME VIII (alternative) and EN 13445-3 are essentially comparable and less conservative for these examples. The K v correction as well as the applied yield criterion (Tresca or von Mises) essentially influence the quality of the more advanced plasticity corrections (e.g. ASME Code Case N-779 and RCC-M). Hence, new proposals are based on a refined K v correction.

  10. Influential Factors for Accurate Load Prediction in a Demand Response Context

    DEFF Research Database (Denmark)

    Wollsen, Morten Gill; Kjærgaard, Mikkel Baun; Jørgensen, Bo Nørregaard

    2016-01-01

    Accurate prediction of a buildings electricity load is crucial to respond to Demand Response events with an assessable load change. However, previous work on load prediction lacks to consider a wider set of possible data sources. In this paper we study different data scenarios to map the influence....... Next, the time of day that is being predicted greatly influence the prediction which is related to the weather pattern. By presenting these results we hope to improve the modeling of building loads and algorithms for Demand Response planning.......Accurate prediction of a buildings electricity load is crucial to respond to Demand Response events with an assessable load change. However, previous work on load prediction lacks to consider a wider set of possible data sources. In this paper we study different data scenarios to map the influence...

  11. Determination of Actual Friction Factors in Metal Forming under Heavy Loaded Regimes Combining Experimental and Numerical Analysis

    Directory of Open Access Journals (Sweden)

    Ana María Camacho

    2016-09-01

    Full Text Available Tribological conditions can change drastically during heavy loaded regimes as experienced in metal forming; this is especially critical when lubrication can only be applied at the early stage of the process because the homogeneous lubricant layer can break along the die-workpiece interface. In these cases, adopting a constant friction factor for the lubricant-surface pair may not be a valid assumption. This paper presents a procedure based on the use of dual friction factor maps to determine friction factors employed in heavy loaded regimes. A finite element (FE simulation is used to obtain the friction factor map for the alloy UNS A96082. Experiments were conducted using four lubricants (aluminum anti-size, MoS2 grease, silicone oil, and copper paste to determine the actual friction curves. The experimental procedure is based on the application of lubricant only at the beginning of the first stage of ring compression, and not at intermediate stages as is usual in typical ring compression tests (RCTs. The results show that for small reductions (rh < 20%, the conventional RCT can be applied because the tribological conditions remain similar. For large reductions (rh > 20%, it is recommended to obtain an average value of the friction factor for every lubricant-surface pair in the range of deformation considered.

  12. Car transfer and wheelchair loading techniques in independent drivers with paraplegia

    Directory of Open Access Journals (Sweden)

    Lisa Lighthall Haubert

    2015-09-01

    Full Text Available Car transfers and wheelchair (WC loading are crucial for independent community participation in persons with complete paraplegia from spinal cord injury, but are complex, physically demanding, and known to provoke shoulder pain. This study aimed to describe techniques and factors influencing car transfer and WC loading for individuals with paraplegia driving their own vehicles and using their personal WCs. Sedans were the most common vehicle driven (59%. Just over half (52% of drivers place their right leg only into the vehicle prior to transfer. Overall, the leading hand was most frequently placed on the driver’s seat (66% prior to transfer and the trailing hand was most often place on the WC seat (48%. Vehicle height influenced leading hand placement but not leg placement such that driver’s of higher profile vehicles were more likely to place their hand on the driver’s seat than those who drove sedans. Body lift time was negatively correlated with level of injury and age and positively correlated with vehicle height and shoulder abduction strength. Drivers who transferred with their leading hand on the steering wheel had significantly higher levels of shoulder pain than those who placed their hand on the driver’s seat or overhead. The majority of participants used both hands (62% to load their WC frame and, overall, most loaded their fame into the back (62% vs. the front seat. Sedan drivers were more likely to load their frame into the front seat than drivers of higher profile vehicles (53% vs. 17%. Average time to load the WC frame (10.7 seconds was 20% of the total WC loading time and was not related to shoulder strength, frame weight or demographic characteristics. Those who loaded their WC frame into the back seat had significantly weaker right shoulder internal rotators. Understanding car transfers and WC loading in independent drivers is crucial to prevent shoulder pain and injury and preserve community participation.

  13. Hierarchy of factors exerting an impact on nutrient load of the Baltic Sea and sustainable management of its drainage basin.

    Science.gov (United States)

    Kiedrzyńska, Edyta; Jóźwik, Adam; Kiedrzyński, Marcin; Zalewski, Maciej

    2014-11-15

    The aim of the paper was to evaluate 23 catchment factors that determine total phosphorus and total nitrogen load to the Baltic Sea. Standard correlation analysis and clustering were used. Both phosphorus and nitrogen loads were found to be positively related to the number of pigs and the human population associated with wastewater treatment plants (WWTPs) per km(2), while the number of cattle and agricultural area were found to influence nitrogen rather than phosphorus load, and the area of forests is negatively related to loads of both nutrients. Clustering indicates an overall north-south pattern in the spatial co-occurrence of socio-ecological factors, with some exceptions discussed in the paper. Positive steps in the Baltic Sea region have already been taken, but much remains to be done. The development of coherent response policies to reduce eutrophication in the Baltic Sea should be based on a comprehensive knowledge base, an appropriate information strategy and learning alliance platform in each drainage river catchments. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Factors associated with higher oxytocin requirements in labor.

    Science.gov (United States)

    Frey, Heather A; Tuuli, Methodius G; England, Sarah K; Roehl, Kimberly A; Odibo, Anthony O; Macones, George A; Cahill, Alison G

    2015-09-01

    To identify clinical characteristics associated with high maximum oxytocin doses in women who achieve complete cervical dilation. A retrospective nested case-control study was performed within a cohort of all term women at a single center between 2004 and 2008 who reached the second stage of labor. Cases were defined as women who had a maximum oxytocin dose during labor >20 mu/min, while women in the control group had a maximum oxytocin dose during labor of ≤20 mu/min. Exclusion criteria included no oxytocin administration during labor, multiple gestations, major fetal anomalies, nonvertex presentation, and prior cesarean delivery. Multiple maternal, fetal, and labor factors were evaluated with univariable analysis and multivariable logistic regression. Maximum oxytocin doses >20 mu/min were administered to 108 women (3.6%), while 2864 women received doses ≤20 mu/min. Factors associated with higher maximum oxytocin dose after adjusting for relevant confounders included maternal diabetes, birthweight >4000 g, intrapartum fever, administration of magnesium, and induction of labor. Few women who achieve complete cervical dilation require high doses of oxytocin. We identified maternal, fetal and labor factors that characterize this group of parturients.

  15. Thermoluminescence of annealed and shock-loaded feldspar

    International Nuclear Information System (INIS)

    Hartmetz, C.P.

    1988-01-01

    Samples of oligoclase and bytownite were shock-loaded to a variety of pressures, and annealed for a variety of temperatures and times. The effect of Mrad doses of gamma-rays on oligoclase TL were also studied. After these treatments, thermoluminescence (TL) and X-ray diffraction (XRD) measurements were made to: (1) determine the effects of shock on terrestrial feldspar and compare with variations in the TL emission of ordinary chondrites (OCs); (2) determine if disordering in feldspar was responsible for any related changes in TL properties of OCs; (3) determine if the combined effect of shock plus annealing causes the changes in TL properties; (4) see if radiation damage from cosmic ray exposure plays a role in the TL variations; (5) examine the implications of this work to the thermal and shock histories of OCs. The lightly shock-loaded and annealed oligoclase samples have a dominant peak temperature of 120-140 C, identical to type 3.3-3.5 OCs. The heavily shocked samples dominant peak is at 230C, similar to type > 3.5 OCs . While the heavily annealed/disordered oligoclase samples have a peak at 280C, this peak is rarely observed in OCs. Radiation damage from Mrad doses of gamma-rays produced no change in peak temperature, but facilitated the shift to higher peak temperatures. The TL sensitivity of the shocked samples decreased by a factor of 25. Samples annealed at low temperatures (438-533C) showed a factor of 2 decrease in TL, but at the highest temperatures, the TL was a factor of 8 higher

  16. Dorzolamide Loaded Niosomal Vesicles: Comparison of Passive and Remote Loading Methods.

    Science.gov (United States)

    Hashemi Dehaghi, Mohadeseh; Haeri, Azadeh; Keshvari, Hamid; Abbasian, Zahra; Dadashzadeh, Simin

    2017-01-01

    Glaucoma is a common progressive eye disorder and the treatment strategies will benefit from nanoparticulate delivery systems with high drug loading and sustained delivery of intraocular pressure lowering agents. Niosomes have been reported as a novel approach to improve drug low corneal penetration and bioavailability characteristics. Along with this, poor entrapment efficiency of hydrophilic drug in niosomal formulation remains as a major formulation challenge. Taking this perspective into consideration, dorzolamide niosomes were prepared employing two different loading methodologies (passive and remote loading methods) and the effects of various formulation variables (lipid to drug ratio, cholesterol percentage, drug concentration, freeze/thaw cycles, TPGS content, and external and internal buffer molarity and pH) on encapsulation efficiency were assessed. Encapsulation of dorzolamide within niosomes increased remarkably by the incorporation of higher cholesterol percentage as well as increasing the total lipid concentration. Remote loading method showed higher efficacy for drug entrapment compared to passive loading technique. Incorporation of TPGS in bilayer led to decrease in EE; however, retarded drug release rate. Scanning electron microscopy (SEM) studies confirmed homogeneous particle distribution, and spherical shape with smooth surface. In conclusion, the highest encapsulation can be obtained using phosphate gradient method and 50% cholesterol in Span 60 niosomal formulation.

  17. The greatest risk for low-back pain among newly educated female health care workers; body weight or physical work load?

    Directory of Open Access Journals (Sweden)

    Jensen Jette

    2012-06-01

    Full Text Available Abstract Background Low back pain (LBP represents a major socioeconomic burden for the Western societies. Both life-style and work-related factors may cause low back pain. Prospective cohort studies assessing risk factors among individuals without prior history of low back pain are lacking. This aim of this study was to determine risk factors for developing low back pain (LBP among health care workers. Methods Prospective cohort study with 2,235 newly educated female health care workers without prior history of LBP. Risk factors and incidence of LBP were assessed at one and two years after graduation. Results Multinomial logistic regression analyses adjusted for age, smoking, and psychosocial factors showed that workers with high physical work load had higher risk for developing LBP than workers with low physical work load (OR 1.8; 95% CI 1.1–2.8. In contrast, workers with high BMI were not at a higher risk for developing LBP than workers with a normal BMI. Conclusion Preventive initiatives for LBP among health care workers ought to focus on reducing high physical work loads rather than lowering excessive body weight.

  18. A Study of Factors Influencing International Students' Choice of Higher Education Institutions

    OpenAIRE

    Akadu, Victor Abia

    2013-01-01

    This paper discusses the factors that influence international students’ choice of higher education institutions. The research conducted using the international students in the University of Nottingham (Malaysia Campus) and Monash University (Malaysia Campus) and survey questionnaires were mainly used to gather primary data for the purpose of this study. Findings from this research indicated that product and university based factors, cost factors, promotion, location and social influences all ...

  19. Vitamin A levels and human immunodeficiency virus load in injection drug users.

    Science.gov (United States)

    Semba, R D; Farzadegan, H; Vlahov, D

    1997-01-01

    Although low plasma vitamin A levels are associated with increased mortality and higher vertical transmission during human immunodeficiency virus (HIV) infection, it is unknown whether plasma low vitamin A levels are a marker for circulating HIV load. We conducted a cross-sectional study within a prospective cohort study of injection drug users in order to evaluate the relationship between plasma vitamin A levels and HIV viral load. Plasma vitamin A level was measured by high-performance liquid chromatography. Infectious viral load was measured by quantitative microculture of serial fivefold dilutions of 10(6) peripheral blood mononuclear cells. A total of 284 HIV-infected adults (79 women, 205 men) were studied. Plasma vitamin A levels consistent with deficiency were found in 28.9% of adults. A total of 38.0% of women and 25.3% of men had vitamin A deficiency (P < 0.04). The median infectious viral load for the entire study population was 8 infectious units per million cells. No significant relationship between plasma vitamin A levels and infectious viral load was observed in these injection drug users. This study suggests that there is no correlation between HIV viral load and plasma vitamin A levels in injection drug users, and these variables may represent independent risk factors during HIV infection. HIV-infected adult women appear to be at higher risk of developing vitamin A deficiency. PMID:9008289

  20. Dextran-based hydrogel containing chitosan microparticles loaded with growth factors to be used in wound healing

    International Nuclear Information System (INIS)

    Ribeiro, M.P.; Morgado, P.I.; Miguel, S.P.; Coutinho, P.; Correia, I.J.

    2013-01-01

    Skin injuries are traumatic events, which are seldom accompanied by complete structural and functional restoration of the original tissue. Different strategies have been developed in order to make the wound healing process faster and less painful. In the present study in vitro and in vivo assays were carried out to evaluate the applicability of a dextran hydrogel loaded with chitosan microparticles containing epidermal and vascular endothelial growth factors, for the improvement of the wound healing process. The carriers' morphology was characterized by scanning electron microscopy. Their cytotoxicity profile and degradation by-products were evaluated through in vitro assays. In vivo experiments were also performed to evaluate their applicability for the treatment of skin burns. The wound healing process was monitored through macroscopic and histological analysis. The macroscopic analysis showed that the period for wound healing occurs in animals treated with microparticle loaded hydrogels containing growth factors that were considerably smaller than that of control groups. Moreover, the histological analysis revealed the absence of reactive or granulomatous inflammatory reaction in skin lesions. The results obtained both in vitro and in vivo disclosed that these systems and its degradation by-products are biocompatible, contributed to the re-establishment of skin architecture and can be used in a near future for the controlled delivery of other bioactive agents used in regenerative medicine. - Highlights: • Evaluation of a hydrogel loaded with microparticles containing growth factors for wound healing • In vitro and in vivo assays were performed to characterize the properties of the skin substitute. • The monitoring of the wound healing process was done by macroscopic and histological analysis

  1. Dextran-based hydrogel containing chitosan microparticles loaded with growth factors to be used in wound healing

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, M.P. [CICS-UBI, Health Sciences Research Center, Faculty of Health Sciences, University of Beira Interior, Covilhã (Portugal); UDI-IPG, Research Unit for Inland Development, Polytechnic Institute of Guarda, Guarda (Portugal); Morgado, P.I.; Miguel, S.P. [CICS-UBI, Health Sciences Research Center, Faculty of Health Sciences, University of Beira Interior, Covilhã (Portugal); Coutinho, P. [CICS-UBI, Health Sciences Research Center, Faculty of Health Sciences, University of Beira Interior, Covilhã (Portugal); UDI-IPG, Research Unit for Inland Development, Polytechnic Institute of Guarda, Guarda (Portugal); Correia, I.J., E-mail: icorreia@ubi.pt [CICS-UBI, Health Sciences Research Center, Faculty of Health Sciences, University of Beira Interior, Covilhã (Portugal)

    2013-07-01

    Skin injuries are traumatic events, which are seldom accompanied by complete structural and functional restoration of the original tissue. Different strategies have been developed in order to make the wound healing process faster and less painful. In the present study in vitro and in vivo assays were carried out to evaluate the applicability of a dextran hydrogel loaded with chitosan microparticles containing epidermal and vascular endothelial growth factors, for the improvement of the wound healing process. The carriers' morphology was characterized by scanning electron microscopy. Their cytotoxicity profile and degradation by-products were evaluated through in vitro assays. In vivo experiments were also performed to evaluate their applicability for the treatment of skin burns. The wound healing process was monitored through macroscopic and histological analysis. The macroscopic analysis showed that the period for wound healing occurs in animals treated with microparticle loaded hydrogels containing growth factors that were considerably smaller than that of control groups. Moreover, the histological analysis revealed the absence of reactive or granulomatous inflammatory reaction in skin lesions. The results obtained both in vitro and in vivo disclosed that these systems and its degradation by-products are biocompatible, contributed to the re-establishment of skin architecture and can be used in a near future for the controlled delivery of other bioactive agents used in regenerative medicine. - Highlights: • Evaluation of a hydrogel loaded with microparticles containing growth factors for wound healing • In vitro and in vivo assays were performed to characterize the properties of the skin substitute. • The monitoring of the wound healing process was done by macroscopic and histological analysis.

  2. Blade design loads on the flow exciting force in centrifugal pump

    International Nuclear Information System (INIS)

    Xu, Y; Yang, A L; Langand, D P; Dai, R

    2012-01-01

    The three-dimensional viscous flow field of two centrifugal pumps, which have the same volute, design head, design flow rate and rotational speed but the blade design load, are analyzed based on large eddy simulation. The comparisons are implemented including the hydraulic efficiencies, flow field characteristics, pressure pulsations and unsteady forces applied on the impellers to investigate the effect of the design blade load on hydraulic performance and flow exciting force. The numerical results show that the efficiency of the pump, the impeller blade of which has larger design load, is improved by 1.1%∼2.9% compared to the centrifugal pump with lower blade design load. The pressure fluctuation of the pump with high design load is more remarkable. Its maximum amplitude of coefficient of static pressure is higher by 43% than the latter. At the same time the amplitude of unsteady radial force is increased by 11.6% in the time domain. The results also imply that the blade design load is an important factor on the excitation force in centrifugal pumps.

  3. Factors Affecting English Language Teaching and Learning in Higher Education

    Science.gov (United States)

    Nguyen, Hong Thi; Warren, Wendy; Fehring, Heather

    2014-01-01

    This paper reports part of a study that aims to explore factors affecting the efficacy of non-major English teaching and learning in Vietnamese higher education through an investigation of classroom practices. Eight non-participant class observations were conducted at HUTECH University, Ho Chi Minh City, Vietnam. The study's findings show that…

  4. Conflict at Higher Education Institutions: Factors and Solutions for Yemen

    Science.gov (United States)

    Muthanna, Abdulghani; Sang, Guoyuan

    2018-01-01

    This is a qualitative case study focusing on reporting the dynamics that cause conflicts between academics and administrators in higher education in Yemen. Drawing upon a critical review of two policy documents, observational research and in-depth interviews with 59 administrators and academics, the article presents the key factors for conflict in…

  5. Lightening the load: perceptual load impairs visual detection in typical adults but not in autism.

    Science.gov (United States)

    Remington, Anna M; Swettenham, John G; Lavie, Nilli

    2012-05-01

    Autism spectrum disorder (ASD) research portrays a mixed picture of attentional abilities with demonstrations of enhancements (e.g., superior visual search) and deficits (e.g., higher distractibility). Here we test a potential resolution derived from the Load Theory of Attention (e.g., Lavie, 2005). In Load Theory, distractor processing depends on the perceptual load of the task and as such can only be eliminated under high load that engages full capacity. We hypothesize that ASD involves enhanced perceptual capacity, leading to the superior performance and increased distractor processing previously reported. Using a signal-detection paradigm, we test this directly and demonstrate that, under higher levels of load, perceptual sensitivity was reduced in typical adults but not in adults with ASD. These findings confirm our hypothesis and offer a promising solution to the previous discrepancies by suggesting that increased distractor processing in ASD results not from a filtering deficit but from enhanced perceptual capacity.

  6. Allostatic Load and Effort-Reward Imbalance: Associations over the Working-Career

    Directory of Open Access Journals (Sweden)

    José Ignacio Cuitún Coronado

    2018-01-01

    Full Text Available Although associations between work stressors and stress-related biomarkers have been reported in cross-sectional studies, the use of single time measurements of work stressors could be one of the reasons for inconsistent associations. This study examines whether repeated reports of work stress towards the end of the working career predicts allostatic load, a measure of chronic stress related physiological processes. Data from waves 2 to 6 of the English Longitudinal Study of Ageing (ELSA were analysed, with a main analytical sample of 2663 older adults (aged 50+ who had at least one measurement of effort-reward imbalance between waves 2–6 and a measurement of allostatic load at wave 6. Cumulative work stress over waves 2–6 were measured by the effort-reward imbalance model. ELSA respondents who had reported two or more occasions of imbalance had a higher (0.3 estimate of the allostatic load index than those who did not report any imbalance, controlling for a range of health and socio-demographic factors, as well as allostatic load at baseline. More recent reports of imbalance were significantly associated with a higher allostatic load index, whereas reports of imbalance from earlier waves of ELSA were not. The accumulation of work related stressors could have adverse effects on chronic stress biological processes.

  7. Factors affecting stream nutrient loads: A synthesis of regional SPARROW model results for the continental United States

    Science.gov (United States)

    Preston, Stephen D.; Alexander, Richard B.; Schwarz, Gregory E.; Crawford, Charles G.

    2011-01-01

    We compared the results of 12 recently calibrated regional SPARROW (SPAtially Referenced Regressions On Watershed attributes) models covering most of the continental United States to evaluate the consistency and regional differences in factors affecting stream nutrient loads. The models - 6 for total nitrogen and 6 for total phosphorus - all provide similar levels of prediction accuracy, but those for major river basins in the eastern half of the country were somewhat more accurate. The models simulate long-term mean annual stream nutrient loads as a function of a wide range of known sources and climatic (precipitation, temperature), landscape (e.g., soils, geology), and aquatic factors affecting nutrient fate and transport. The results confirm the dominant effects of urban and agricultural sources on stream nutrient loads nationally and regionally, but reveal considerable spatial variability in the specific types of sources that control water quality. These include regional differences in the relative importance of different types of urban (municipal and industrial point vs. diffuse urban runoff) and agriculture (crop cultivation vs. animal waste) sources, as well as the effects of atmospheric deposition, mining, and background (e.g., soil phosphorus) sources on stream nutrients. Overall, we found that the SPARROW model results provide a consistent set of information for identifying the major sources and environmental factors affecting nutrient fate and transport in United States watersheds at regional and subregional scales. ?? 2011 American Water Resources Association. This article is a U.S. Government work and is in the public domain in the USA.

  8. Low cognitive load strengthens distractor interference while high load attenuates when cognitive load and distractor possess similar visual characteristics.

    Science.gov (United States)

    Minamoto, Takehiro; Shipstead, Zach; Osaka, Naoyuki; Engle, Randall W

    2015-07-01

    Studies on visual cognitive load have reported inconsistent effects of distractor interference when distractors have visual characteristic that are similar to the cognitive load. Some studies have shown that the cognitive load enhances distractor interference, while others reported an attenuating effect. We attribute these inconsistencies to the amount of cognitive load that a person is required to maintain. Lower amounts of cognitive load increase distractor interference by orienting attention toward visually similar distractors. Higher amounts of cognitive load attenuate distractor interference by depleting attentional resources needed to process distractors. In the present study, cognitive load consisted of faces (Experiments 1-3) or scenes (Experiment 2). Participants performed a selective attention task in which they ignored face distractors while judging a color of a target dot presented nearby, under differing amounts of load. Across these experiments distractor interference was greater in the low-load condition and smaller in the high-load condition when the content of the cognitive load had similar visual characteristic to the distractors. We also found that when a series of judgments needed to be made, the effect was apparent for the first trial but not for the second. We further tested an involvement of working memory capacity (WMC) in the load effect (Experiment 3). Interestingly, both high and low WMC groups received an equivalent effect of the cognitive load in the first distractor, suggesting these effects are fairly automatic.

  9. Modeling and Finite Element Analysis of Load-Carrying Performance of a Wind Turbine Considering the Influence of Assembly Factors

    Directory of Open Access Journals (Sweden)

    Jianmei Wang

    2017-03-01

    Full Text Available In this work, a wind turbine shrink disk is used as the research object to investigate load-carrying performance of a multi-layer interference fit, and the theoretical model and finite element model are constructed. According to those models, a MW-level turbine shrink disk is designed, and a test device is developed to apply torque to this turbine shrink disk by hydraulic jack. Then, the circumferential slip between the contact surfaces is monitored and the slip of all contact surfaces is zero. This conclusion verifies the reasonability of the proposed models. The effect of the key influencing factors, such as machining deviation, assembly clearance and propel stroke, were analyzed. The contact pressure and load torque of the mating surfaces were obtained by building typical models with different parameters using finite element analysis (FEA. The results show that the minimum assembly clearance and the machining deviation within the machining range have little influence on load-carrying performance of multi-layer interference fit, while having a greater influence on the maximum assembly clearance and the propel stroke. The results also show that the load-carrying performance of a multiple-layer interference fit can be ensured only if the key factors are set within a reasonable design range. To avoid the abnormal operation of equipment caused by insufficient load torque, the propel stroke during practical assembly should be at least 0.95 times the designed propel stroke, which is significant in guiding the design and assembly of the multi-layer interference fit.

  10. Factors associated with mother-to-child transmission of HIV-1 despite a maternal viral load EPF-ANRS CO1).

    Science.gov (United States)

    Tubiana, Roland; Le Chenadec, Jerome; Rouzioux, Christine; Mandelbrot, Laurent; Hamrene, Karima; Dollfus, Catherine; Faye, Albert; Delaugerre, Constance; Blanche, Stephane; Warszawski, Josiane

    2010-02-15

    The rate of mother-to-child transmission (MTCT) of human immunodeficiency virus (HIV) type 1 is as low as 0.5% in non-breast-feeding mothers who delivered at term while receiving antiretroviral therapy with a plasma viral load <500 copies/mL. This situation accounted for 20% of the infected children born during the period 1997-2006 in the French Perinatal Cohort. We aimed to identify factors associated with such residual transmission risk. We performed a case-control study nested in the aforementioned subpopulation of the French Perinatal Cohort. Nineteen case patients (transmitters) and 60 control subjects (nontransmitters) were included. Case patients and control subjects did not differ by geographical origin, gestational age at HIV diagnosis, type of antiretroviral therapy received, or elective Cesarean delivery. Case patients were less often receiving treatment at the time that they conceived pregnancy than control subjects (16% vs 45%; P=.017). A lower proportion of case patients had a viral load <500 copies/mL, compared with control subjects, at 14 weeks (0% vs 38.1%; P=.02), 28 weeks (7.7% vs 62.1%; P=.005), and 32 weeks: (21.4% vs 71.1%; P=.004). The difference remained significant when we restricted analysis to the 10 of 16 intrapartum transmission cases. In a multivariate analysis at 30+/-4 weeks adjusted for viral load, CD4(+) T cell count, and time at antiretroviral therapy initiation, viral load was the only factor independently associated with MTCT of HIV (adjusted odds ratio, 23.2; 95% confidence interval, 3.5-553; P<.001). Early and sustained control of viral load is associated with a decreasing residual risk of MTCT of HIV-1. Guidelines should take into account not only CD4(+) T cell count and risk of preterm delivery, but also baseline HIV-1 load for deciding when to start antiretroviral therapy during pregnancy.

  11. Probability Based Evaluation of Vehicular Bridge Load using Weigh-in-Motion Data

    OpenAIRE

    Widi Nugraha; Indra Djati Sidi

    2016-01-01

    Load and Resistance Factored Design (LRFD) method for designing bridge in Indonesia have been implemented for more than 25 years. LRFD method treating loads and strengths variables as random variables with specific safety factors for different loads and strengths variables type. The nominal loads, load factors, reduction factors, and other criteria for bridge design code can be determined to meet the reliability criteria. Statistical data of weigh-in-motion (WIM) vehicular loads measurement i...

  12. Switch Panel wear loading - a parametric study regarding governing train operational factors

    Science.gov (United States)

    Hiensch, E. J. M.; Burgelman, N.

    2017-09-01

    The acting forces and resulting material degradation at the running surfaces of wheels and rail are determined by vehicle, track, interface and operational characteristics. To effectively manage the experienced wear, plastic deformation and crack development at wheels and rail, the interaction between vehicle and track demands a system approach both in maintenance and in design. This requires insight into the impact of train operational parameters on rail- and wheel degradation, in particular at switches and crossings due to the complex dynamic behaviour of a railway vehicle at a turnout. A parametric study was carried out by means of vehicle-track simulations within the VAMPIRE® multibody simulation software, performing a sensitivity analysis regarding operational factors and their impact on expected switch panel wear loading. Additionally, theoretical concepts were cross-checked with operational practices by means of a case study in response to a dramatic change in lateral rail wear development at specific switches in Dutch track. Data from train operation, track maintenance and track inspection were analysed, providing further insight into the operational dependencies. From the simulations performed in this study, it was found that switch rail lateral wear loading at the diverging route of a 1:9 type turnout is significantly influenced by the level of wheel-rail friction and to a lesser extent by the direction of travel (facing or trailing). The influence of other investigated parameters, being vehicle speed, traction, gauge widening and track layout is found to be small. Findings from the case study further confirm the simulation outcome. This research clearly demonstrates the contribution flange lubrication can have in preventing abnormal lateral wear at locations where the wheel-rail interface is heavily loaded.

  13. Geometrical Sparing Factors for the Rectum and Bladder in the Prediction of Grade 2 and Higher Complications After High-Dose-Rate Brachytherapy for Cervical Cancer

    International Nuclear Information System (INIS)

    Chen, S.-W.; Liang, J.-A.; Hung, Y.-C.; Yeh, L.-S.; Chang, W.-C.; Yang, S.-N.; Lin, F.-J.

    2009-01-01

    Purpose: This study aimed to assess the predictive values of geometrical sparing factors for the rectum and bladder in high-dose-rate intracavitary brachytherapy (HDRICB) for Grade 2 and higher late sequelae in patients with cervical cancer. Methods: A total of 392 patients were enrolled in this study. They were treated with external beam radiotherapy to the pelvis, after which HDRICB was performed using Ir-192 remote after-loading at 1-week intervals for three or four sessions. The geometrical sparing factor (GSF) was defined as the average of the ratios between the reference doses and the Point A dose. Results: A total of 46 patients (11.7%) had Grade 2 or higher late rectal complications (36 Grade 2, 9 Grade 3, and 1 Grade 4). In all, 32 patients (8.2%) had Grade 2 or higher late bladder complications (14 Grade 2, 16 Grade 3, and 2 Grade 4). Multivariate analysis demonstrated a high risk of rectal sequelae in patients who developed bladder complications (p = 0.0004, hazard ratio 3.54) and had a rectal GSF greater than 0.7 (p = 0.01, hazard ratio 1.99). The high risk factors for bladder complications were development of rectal complications (p = 0.0004, hazard ratio 3.74), concurrent chemotherapy (p = 0.0001, relative risk 3.94), and a bladder GSF greater than 0.9 (p = 0.01, hazard ratio, 2.53). Conclusion: This study demonstrates the predictive value of GSFs in HDRICB for cervical cancer. Patients with rectal GSFs greater than 0.7 or bladder GSFs greater than 0.9 are at risk for Grade 2 and higher late sequelae.

  14. Geometrical sparing factors for the rectum and bladder in the prediction of grade 2 and higher complications after high-dose-rate brachytherapy for cervical cancer.

    Science.gov (United States)

    Chen, Shang-Wen; Liang, Ji-An; Hung, Yao-Ching; Yeh, Lian-Shung; Chang, Wei-Chun; Yang, Shih-Neng; Lin, Fang-Jen

    2009-12-01

    This study aimed to assess the predictive values of geometrical sparing factors for the rectum and bladder in high-dose-rate intracavitary brachytherapy (HDRICB) for Grade 2 and higher late sequelae in patients with cervical cancer. A total of 392 patients were enrolled in this study. They were treated with external beam radiotherapy to the pelvis, after which HDRICB was performed using Ir-192 remote after-loading at 1-week intervals for three or four sessions. The geometrical sparing factor (GSF) was defined as the average of the ratios between the reference doses and the Point A dose. A total of 46 patients (11.7%) had Grade 2 or higher late rectal complications (36 Grade 2, 9 Grade 3, and 1 Grade 4). In all, 32 patients (8.2%) had Grade 2 or higher late bladder complications (14 Grade 2, 16 Grade 3, and 2 Grade 4). Multivariate analysis demonstrated a high risk of rectal sequelae in patients who developed bladder complications (p = 0.0004, hazard ratio 3.54) and had a rectal GSF greater than 0.7 (p = 0.01, hazard ratio 1.99). The high risk factors for bladder complications were development of rectal complications (p = 0.0004, hazard ratio 3.74), concurrent chemotherapy (p = 0.0001, relative risk 3.94), and a bladder GSF greater than 0.9 (p = 0.01, hazard ratio, 2.53). This study demonstrates the predictive value of GSFs in HDRICB for cervical cancer. Patients with rectal GSFs greater than 0.7 or bladder GSFs greater than 0.9 are at risk for Grade 2 and higher late sequelae.

  15. Factors related to external loads in buried pipelines; Consideracoes quanto as variaveis relacionadas ao carregamento externo em dutos enterrados

    Energy Technology Data Exchange (ETDEWEB)

    Provenzano, Carlos E.C.; Silva, Breno S.; Fernandes, Lincoln F.; Santos Junior, Sergio J.F. [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil); Louzada, Carlos H.C.M.

    2005-07-01

    Work of heavy equipment or vehicles above existent right-of-ways, may cause undesired external overload at buried pipelines in operation. The effect of these loads shall be analyzed considering the deflections and stresses on the pipelines. The major variables, nominal diameter, thickness, material, soil parameters, operation pressure and external loads shall be related and verified according to the limits from original project. Cases when the external loads cause higher efforts, the traffic over the pipelines shall be restricted in order to avoid damages. In other cases, it may be adapted to any technical alternatives to modify the parameters in such a way to make possible work above the right-of-way, such as increase the machine support area, increase backfill covering, a reduction in the internal operation pressure in a short time, etc. This work presents the study on the parameters used to establish the maximum allowable external loads over buried pipelines in operation. (author)

  16. Risk factors and long-term outcomes of pediatric liver transplant recipients with chronic high Epstein-Barr virus loads.

    Science.gov (United States)

    Kamei, Hideya; Ito, Yoshinori; Kawada, Junichi; Ogiso, Satoshi; Onishi, Yasuharu; Komagome, Masahiko; Kurata, Nobuhiko; Ogura, Yasuhiro

    2018-04-20

    Serial monitoring of Epstein-Barr virus (EBV) reveals that certain pediatric liver transplant (LT) recipients exhibit high EBV loads for long periods. We investigated the incidence and risk factors of chronic high EBV (CHEBV) loads (continuous EBV DNA >10 000 IU/mL of whole blood for ≥6 months) and long-term outcomes. This single center, retrospective observational study investigated pediatric LT recipients who survived ≥6 months. We quantitated EBV DNA weekly during hospitalization and subsequently every 4 or 6 weeks at the outpatient clinic. Tacrolimus was maintained at a low trough level (5000 IU/mL). Thirty-one of 77 LT recipients developed CHEBV. Univariate analysis revealed that age 35 minutes, graft-to-recipient weight ratio (GRWR) >2.7%, and preoperative EBV seronegativity were significantly associated with the development of CHEBV loads. Multivariate analysis identified significant associations of CHEBV with WIT >35 minutes, GRWR >2.7%, and preoperative seronegative. None of the recipients developed post-transplantation lymphoproliferative disorder. Survival rates of patients with and without CHEBV loads were not significantly different. A significant number of pediatric LT recipients developed CHEBV loads. Long WIT, high GRWR, and preoperative EBV seronegativity were significantly associated with the development of CHEBV loads. Although the long-term outcomes of patients with or without CHEBV loads were not significantly different, further studies of more subjects are warranted. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Cognitive Load of Learner Control: Extraneous or Germane Load?

    Directory of Open Access Journals (Sweden)

    Mieke Vandewaetere

    2013-01-01

    Full Text Available Computer-based learning environments become more tailored when learners can exert control over one or more parts of the learning process. Learner control (LC demands additional efforts of learners because, in addition to learning, they also have to monitor that learning. As a consequence, LC may cause additional cognitive load and even cognitive overload. The central question in this study is what type of cognitive load is induced by LC and whether the experienced load is related to learning outcomes. For this study, half of the students had control over task selection, while the other half had not. Within each condition, students were assigned to a single treatment, with the primary task to solely focus on the learning content, and a dual treatment, comprising a primary task and a secondary task. The results indicate that LC did not impose higher cognitive load as measured by secondary task scores and mental effort ratings.

  18. Quantification of baseline pupillary response and task-evoked pupillary response during constant and incremental task load.

    Science.gov (United States)

    Mosaly, Prithima R; Mazur, Lukasz M; Marks, Lawrence B

    2017-10-01

    The methods employed to quantify the baseline pupil size and task-evoked pupillary response (TEPR) may affect the overall study results. To test this hypothesis, the objective of this study was to assess variability in baseline pupil size and TEPR during two basic working memory tasks: constant load of 3-letters memorisation-recall (10 trials), and incremental load memorisation-recall (two trials of each load level), using two commonly used methods (1) change from trail/load specific baseline, (2) change from constant baseline. Results indicated that there was a significant shift in baseline between the trails for constant load, and between the load levels for incremental load. The TEPR was independent of shifts in baseline using method 1 only for constant load, and method 2 only for higher levels of incremental load condition. These important findings suggest that the assessment of both the baseline and methods to quantify TEPR are critical in ergonomics application, especially in studies with small number of trials per subject per condition. Practitioner Summary: Quantification of TEPR can be affected by shifts in baseline pupil size that are most likely affected by non-cognitive factors when other external factors are kept constant. Therefore, quantification methods employed to compute both baseline and TEPR are critical in understanding the information processing of humans in practical ergonomics settings.

  19. Determination of the usage factor of components after cyclic loading using high-resolution microstructural investigations

    International Nuclear Information System (INIS)

    Seibold, A.; Scheibe, A.; Assmann, H.D.

    1989-01-01

    The usage factor can be derived from the quantification of the structure changes and the allocation of the microstructural state to the fatigue curves of the component materials. Using the example of the low alloy fine grain structural steel 20 Mn Mo Ni 5 5 (annealed structure), the relationship between micro-structure and the number of load cycles is shown in the form of a calibration curve. By high resolution structural investigation, the usage factor can be determined to n = N/N B ≅ 0.5 under given vibration stress. Only a small volume sample is required for the electron microscope examination. (orig./DG) [de

  20. Women in Higher Education: Exploring Stressful Workplace Factors and Coping Strategies

    Science.gov (United States)

    Kersh, Renique

    2018-01-01

    For women administrators in higher education, workplace factors like managing multiple roles; work bleeding into personal life; issues with leadership; discrimination and marginalization; and role insufficiency (i.e., ambiguity in work roles and reduced sense of control) contribute to increased workplace stress. Individual coping responses are…

  1. Quantification of Epstein-Barr virus DNA load, interleukin-6, interleukin-10, transforming growth factor-β1 and stem cell factor in plasma of patients with nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Tan, Eng-lai; Selvaratnam, G; Kananathan, R; Sam, Choon-kook

    2006-01-01

    Nasopharyngeal carcinoma (NPC) is a common epithelial neoplasm among the Chinese populations in Southern China and South East Asia. Epstein-Barr virus (EBV) is known to be an important etiologic agent of NPC and the viral gene products are frequently detected in NPC tissues along with elevated antibody titres to the viral proteins (VCA and EA) in a majority of patients. Elevated plasma EBV DNA load is regarded as an important marker for the presence of the disease and for the monitoring of disease progression. However, other serum/plasma parameters such as the levels of certain interleukins and growth factors have also been implicated in NPC. The objectives of the present study are, 1) to investigate the correlations between plasma EBV DNA load and the levels of interleukin (IL)-6, IL-10, TGF-β1 and SCF (steel factor) and 2) to relate these parameters to the stages of NPC and the effect of treatment. A total of 78 untreated NPC patients were enrolled in this study. Of these, 51 were followed-up after treatment. The remaining patients had irregular or were lost to follow-up. Plasma EBV DNA was quantified using real-time quantitative PCR. The levels of plasma interleukins and growth factors were quantified using ELISA. A significant decrease in EBV DNA load was detected in plasma of untreated NPC patients (1669 ± 637 copies/mL; n = 51) following treatment (57 ± 37 copies/mL, p < 0.05); n = 51). Plasma EBV DNA load was shown to be a good prognosticator for disease progression and clinical outcome in five of the follow-up patients. A significant difference in IL-6 levels was noted between the untreated patients (164 ± 37 pg/mL; n = 51) and following treatment (58 ± 16 pg/mL, p < 0.05; n = 51). Positive correlations between EBV DNA load and IL-10 (r(49) = 0.535, p < 0.01), between IL6 and IL-10 (r(49) = 0.474, p < 0.01) and between TGF and SCF (r(49) = 0.464, p < 0.01) were observed in patients following treatment. None of the parameters tested including Ig

  2. Exploring item and higher order factor structure with the Schmid-Leiman solution: syntax codes for SPSS and SAS.

    Science.gov (United States)

    Wolff, Hans-Georg; Preising, Katja

    2005-02-01

    To ease the interpretation of higher order factor analysis, the direct relationships between variables and higher order factors may be calculated by the Schmid-Leiman solution (SLS; Schmid & Leiman, 1957). This simple transformation of higher order factor analysis orthogonalizes first-order and higher order factors and thereby allows the interpretation of the relative impact of factor levels on variables. The Schmid-Leiman solution may also be used to facilitate theorizing and scale development. The rationale for the procedure is presented, supplemented by syntax codes for SPSS and SAS, since the transformation is not part of most statistical programs. Syntax codes may also be downloaded from www.psychonomic.org/archive/.

  3. Reliability Analysis of Offshore Jacket Structures with Wave Load on Deck using the Model Correction Factor Method

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Friis-Hansen, P.; Nielsen, J.S.

    2006-01-01

    failure/collapse of jacket type platforms with wave in deck loads using the so-called Model Correction Factor Method (MCFM). A simple representative model for the RSR measure is developed and used in the MCFM technique. A realistic example is evaluated and it is seen that it is possible to perform...

  4. Transient beam loading in the ALS harmonic RF system

    International Nuclear Information System (INIS)

    Byrd, J.; De Santis, S.; Georgsson, M.; Stover, G.; Fox, J.; Prabhakar, S.; Teytelman, D.

    2000-01-01

    We report on the commissioning of a higher harmonic radiofrequency system at the Advanced Light Source, designed to improve the beam lifetime. We have achieved an increase above a factor of two in our best results up to now. Transient beam loading of the harmonic cavities, due to the unequal fill patterns, creates the greatest limitation on lifetime improvement. We also describe several interesting effects on the operation of the longitudinal and transverse multibunch feedback system

  5. Processing Capacity under Perceptual and Cognitive Load: A Closer Look at Load Theory

    Science.gov (United States)

    Fitousi, Daniel; Wenger, Michael J.

    2011-01-01

    Variations in perceptual and cognitive demands (load) play a major role in determining the efficiency of selective attention. According to load theory (Lavie, Hirst, Fockert, & Viding, 2004) these factors (a) improve or hamper selectivity by altering the way resources (e.g., processing capacity) are allocated, and (b) tap resources rather than…

  6. Implementing Research in Professional Higher Education: Factors That Influence Lecturers' Perceptions

    Science.gov (United States)

    Griffioen, Didi M. E.; de Jong, Uulkje

    2015-01-01

    Higher professional education in Europe has changed from teaching-only institutes to hybrids of teaching and research. The purpose of this study was to examine factors that influence the judgements of lecturers about new organisational goals and perceptions of their new research-related competencies. Lecturers' judgements of new organisational…

  7. Performance study of K{sub e} factors in simplified elastic plastic fatigue analyses with emphasis on thermal cyclic loading

    Energy Technology Data Exchange (ETDEWEB)

    Lang, Hermann, E-mail: hermann.lang@areva.com [AREVA NP GmbH, PEEA-G, Henri-Dunant-Strasse 50, 91058 Erlangen (Germany); Rudolph, Juergen; Ziegler, Rainer [AREVA NP GmbH, PEEA-G, Henri-Dunant-Strasse 50, 91058 Erlangen (Germany)

    2011-08-15

    As code-based fully elastic plastic code conforming fatigue analyses are still time consuming, simplified elastic plastic analysis is often applied. This procedure is known to be overly conservative for some conditions due to the applied plastification (penalty) factor K{sub e}. As a consequence, less conservative fully elastic plastic fatigue analyses based on non-linear finite element analyses (FEA) or simplified elastic plastic analysis based on more realistic K{sub e} factors have to be used for fatigue design. The demand for more realistic K{sub e} factors is covered as a requirement of practical fatigue analysis. Different code-based K{sub e} procedures are reviewed in this paper with special regard to performance under thermal cyclic loading conditions. Other approximation formulae such as those by Neuber, Seeger/Beste or Kuehnapfel are not evaluated in this context because of their applicability to mechanical loading excluding thermal cyclic loading conditions typical for power plant operation. Besides the current code-based K{sub e} corrections, the ASME Code Case N-779 (e.g. Adam's proposal) and its modification in ASME Section VIII is considered. Comparison of elastic plastic results and results from the Rules for Nuclear Facility Components and Rules for Pressure Vessels reveals a considerable overestimation of usage factor in the case of ASME III and KTA 3201.2 for the examined examples. Usage factors according to RCC-M, Adams (ASME Code Case N-779), ASME VIII (alternative) and EN 13445-3 are essentially comparable and less conservative for these examples. The K{sub v} correction as well as the applied yield criterion (Tresca or von Mises) essentially influence the quality of the more advanced plasticity corrections (e.g. ASME Code Case N-779 and RCC-M). Hence, new proposals are based on a refined K{sub v} correction.

  8. Sex-specific interaction effects of age, occupational status, and workplace stress on psychiatric symptoms and allostatic load among healthy Montreal workers.

    Science.gov (United States)

    Juster, Robert-Paul; Moskowitz, D S; Lavoie, Joel; D'Antono, Bianca

    2013-11-01

    Socio-demographics and workplace stress may affect men and women differently. The aim of this cross-sectional study was to assess sex-specific interactions among age, occupational status, and workplace Demand-Control-Support (D-C-S) factors in relation to psychiatric symptoms and allostatic load levels representing multi-systemic "wear and tear". It was hypothesized that beyond main effects, D-C-S factors would be moderated by occupational status and age in sex-specific directions predictive of subjective psychiatric symptoms and objective physiological dysregulations. Participants included healthy male (n = 81) and female (n = 118) Montreal workers aged 20 to 64 years (Men: M = 39.4 years, SD = 11.3; Women: M = 42.8 years, SD = 11.38). The Job Content Questionnaire was administered to assess workplace D-C-S factors that included psychological demands, decisional latitude, and social support. Occupational status was coded using the Nam--Powers--Boyd system derived from the Canadian census. Psychiatric symptoms were assessed using the Beck Anxiety Scale and the Beck Depression Inventory II. Sex-specific allostatic load indices were calculated based on fifteen biomarkers. Regression analyses revealed that higher social support was associated with less depressive symptoms in middle aged (p = 0.033) and older men (p = 0.027). Higher occupational status was associated with higher allostatic load levels for men (p = 0.035), while the reverse occurred for women (p = 0.048). Women with lower occupational status but with higher decision latitude had lower allostatic load levels, as did middle-aged (p = 0.031) and older women (p = 0.003) with higher psychological demands. In summary, age and occupational status moderated workplace stress in sex-specific ways that have occupational health implications.

  9. Process for improving the load factor of an electricity generating power station

    International Nuclear Information System (INIS)

    Rostaing, Michel.

    1974-01-01

    A description is given of a process for improving the load factor of an electricity generating power station feeding a supply network in which all or part of the power not required by the network during off-peak hours is used for producing hydrogen which is then stored. The stored hydrogen is then burned and the heat generated is employed for superheating the steam generated by the nuclear reactor of the power plant. This combustion is carried out permanently. The hydrogen is produced by water electrolysis. The oxygen also produced in this manner is used as a comburent in the combustion of the hydrogen. The reactor is of the pressurized water type [fr

  10. [Distribution of neural memory, loading factor, its regulation and optimization].

    Science.gov (United States)

    Radchenko, A N

    1999-01-01

    Recording and retrieving functions of the neural memory are simulated as a control of local conformational processes in neural synaptic fields. The localization of conformational changes is related to the afferent temporal-spatial pulse pattern flow, the microstructure of connections and a plurality of temporal delays in synaptic fields and afferent pathways. The loci of conformations are described by sets of afferent addresses named address domains. Being superimposed on each other, address domains form a multilayer covering of the address space of the neuron or the ensemble. The superposition factor determines the dissemination of the conformational process, and the fuzzing of memory, and its accuracy and reliability. The engram is formed as detects in the packing of the address space and hence can be retrieved in inverse form. The accuracy of the retrieved information depends on the threshold level of conformational transitions, the distribution of conformational changes in synaptic fields of the neuronal population, and the memory loading factor. The latter is represented in the model by a slow potential. It reflects total conformational changes and displaces the membrane potential to monostable conformational regimes, by governing the exit from the recording regime, the potentiation of the neurone, and the readiness to reproduction. A relative amplitude of the slow potential and the coefficient of postconformational modification of ionic conductivity, which provides maximum reliability, accuracy, and capacity of memory, are calculated.

  11. Factors Influencing the Organizational Stress among Teachers Working in Higher Education Sector in Kerala: An Empirical Analysis

    Science.gov (United States)

    Areekkuzhiyil, Santhosh

    2014-01-01

    The study aims to explore the various factors that influence the organizational stress of teachers working in higher education sector in the state of Kerala. The data required for the study has been conveniently collected from 200 teachers working in higher education sector. Exploratory factor analysis revealed nine factors, which significantly…

  12. Does the adolescent patellar tendon respond to 5 days of cumulative load during a volleyball tournament?

    NARCIS (Netherlands)

    van Ark, M.; Docking, S.I.; van den Akker-Scheek, I.; Rudavsky, A.; Rio, E.; Zwerver, J.; Cook, J.L.

    Patellar tendinopathy (jumper's knee) has a high prevalence in jumping athletes. Excessive load on the patellar tendon through high volumes of training and competition is an important risk factor. Structural changes in the tendon are related to a higher risk of developing patellar tendinopathy. The

  13. Impact of load-related neural processes on feature binding in visuospatial working memory.

    Directory of Open Access Journals (Sweden)

    Nicole A Kochan

    Full Text Available BACKGROUND: The capacity of visual working memory (WM is substantially limited and only a fraction of what we see is maintained as a temporary trace. The process of binding visual features has been proposed as an adaptive means of minimising information demands on WM. However the neural mechanisms underlying this process, and its modulation by task and load effects, are not well understood. OBJECTIVE: To investigate the neural correlates of feature binding and its modulation by WM load during the sequential phases of encoding, maintenance and retrieval. METHODS AND FINDINGS: 18 young healthy participants performed a visuospatial WM task with independent factors of load and feature conjunction (object identity and position in an event-related functional MRI study. During stimulus encoding, load-invariant conjunction-related activity was observed in left prefrontal cortex and left hippocampus. During maintenance, greater activity for task demands of feature conjunction versus single features, and for increased load was observed in left-sided regions of the superior occipital cortex, precuneus and superior frontal cortex. Where these effects were expressed in overlapping cortical regions, their combined effect was additive. During retrieval, however, an interaction of load and feature conjunction was observed. This modulation of feature conjunction activity under increased load was expressed through greater deactivation in medial structures identified as part of the default mode network. CONCLUSIONS AND SIGNIFICANCE: The relationship between memory load and feature binding qualitatively differed through each phase of the WM task. Of particular interest was the interaction of these factors observed within regions of the default mode network during retrieval which we interpret as suggesting that at low loads, binding processes may be 'automatic' but at higher loads it becomes a resource-intensive process leading to disengagement of activity in this

  14. Analysis of Global Sensitivity of Landing Variables on Landing Loads and Extreme Values of the Loads in Carrier-Based Aircrafts

    Directory of Open Access Journals (Sweden)

    Jin Zhou

    2018-01-01

    Full Text Available When a carrier-based aircraft is in arrested landing on deck, the impact loads on landing gears and airframe are closely related to landing states. The distribution and extreme values of the landing loads obtained during life-cycle analysis provide an important basis for buffering parameter design and fatigue design. In this paper, the effect of the multivariate distribution was studied based on military standards and guides. By establishment of a virtual prototype, the extended Fourier amplitude sensitivity test (EFAST method is applied on sensitivity analysis of landing variables. The results show that sinking speed and rolling angle are the main influencing factors on the landing gear’s course load and vertical load; sinking speed, rolling angle, and yawing angle are the main influencing factors on the landing gear’s lateral load; and sinking speed is the main influencing factor on the barycenter overload. The extreme values of loads show that the typical condition design in the structural strength analysis is safe. The maximum difference value of the vertical load of the main landing gear is 12.0%. This research may provide some reference for structure design of landing gears and compilation of load spectrum for carrier-based aircrafts.

  15. Transcription factor assisted loading and enhancer dynamics dictate the hepatic fasting response

    Science.gov (United States)

    Goldstein, Ido; Baek, Songjoon; Presman, Diego M.; Paakinaho, Ville; Swinstead, Erin E.; Hager, Gordon L.

    2017-01-01

    Fasting elicits transcriptional programs in hepatocytes leading to glucose and ketone production. This transcriptional program is regulated by many transcription factors (TFs). To understand how this complex network regulates the metabolic response to fasting, we aimed at isolating the enhancers and TFs dictating it. Measuring chromatin accessibility revealed that fasting massively reorganizes liver chromatin, exposing numerous fasting-induced enhancers. By utilizing computational methods in combination with dissecting enhancer features and TF cistromes, we implicated four key TFs regulating the fasting response: glucocorticoid receptor (GR), cAMP responsive element binding protein 1 (CREB1), peroxisome proliferator activated receptor alpha (PPARA), and CCAAT/enhancer binding protein beta (CEBPB). These TFs regulate fuel production by two distinctly operating modules, each controlling a separate metabolic pathway. The gluconeogenic module operates through assisted loading, whereby GR doubles the number of sites occupied by CREB1 as well as enhances CREB1 binding intensity and increases accessibility of CREB1 binding sites. Importantly, this GR-assisted CREB1 binding was enhancer-selective and did not affect all CREB1-bound enhancers. Single-molecule tracking revealed that GR increases the number and DNA residence time of a portion of chromatin-bound CREB1 molecules. These events collectively result in rapid synergistic gene expression and higher hepatic glucose production. Conversely, the ketogenic module operates via a GR-induced TF cascade, whereby PPARA levels are increased following GR activation, facilitating gradual enhancer maturation next to PPARA target genes and delayed ketogenic gene expression. Our findings reveal a complex network of enhancers and TFs that dynamically cooperate to restore homeostasis upon fasting. PMID:28031249

  16. Urban Saturated Power Load Analysis Based on a Novel Combined Forecasting Model

    Directory of Open Access Journals (Sweden)

    Huiru Zhao

    2015-03-01

    Full Text Available Analysis of urban saturated power loads is helpful to coordinate urban power grid construction and economic social development. There are two different kinds of forecasting models: the logistic curve model focuses on the growth law of the data itself, while the multi-dimensional forecasting model considers several influencing factors as the input variables. To improve forecasting performance, a novel combined forecasting model for saturated power load analysis was proposed in this paper, which combined the above two models. Meanwhile, the weights of these two models in the combined forecasting model were optimized by employing a fruit fly optimization algorithm. Using Hubei Province as the example, the effectiveness of the proposed combined forecasting model was verified, demonstrating a higher forecasting accuracy. The analysis result shows that the power load of Hubei Province will reach saturation in 2039, and the annual maximum power load will reach about 78,630 MW. The results obtained from this proposed hybrid urban saturated power load analysis model can serve as a reference for sustainable development for urban power grids, regional economies, and society at large.

  17. Barriers to electricity load shift in companies: A survey-based exploration of the end-user perspective

    International Nuclear Information System (INIS)

    Olsthoorn, Mark; Schleich, Joachim; Klobasa, Marian

    2015-01-01

    As countries move toward larger shares of renewable electricity, the slow diffusion of active electricity load management should concern energy policy makers and users alike. Active load management can increase capacity factors and thereby reduce the need for new capacity, improve reliability, and lower electricity prices. This paper conceptually and empirically explores barriers to load shift in industry from an end-user perspective. An online survey, based on a taxonomy of barriers developed in the realm of energy efficiency, was carried out among manufacturing sites in mostly Southern Germany. Findings suggest that the most important barriers are risk of disruption of operations, impact on product quality, and uncertainty about cost savings. Of little concern are access to capital, lack of employee skills, and data security. Statistical tests suggest that companies for which electricity has higher strategic value rate financial and regulatory risk higher than smaller ones. Companies with a continuous production process report lower barrier scores than companies using batch or just-in-time production. A principal component analysis clusters the barriers and multivariate analysis with the factor scores confirms the prominence of technical risk as a barrier to load shift. The results provide guidance for policy making and future empirical studies. - Highlights: • We quantitatively assess barriers to load shift adoption among manufacturing firms. • Conceptually, we build on the literature on barriers to energy efficiency. • The most important barriers are interference with production and with product quality. • Companies with a continuous production process report lower barrier scores. • The barriers to load shift may be organized in distinct clusters via principal component analysis

  18. 10^{7}-A load-current B-dot monitor: Simulations, design, and performance

    Directory of Open Access Journals (Sweden)

    D. V. Rose

    2010-04-01

    Full Text Available A B-dot monitor that measures the current 6 cm from the axis of dynamic loads fielded on 10^{7}-A multiterawatt pulsed-power accelerators has been developed. The monitor improves upon the multimegampere load-current gauge described in Phys. Rev. ST Accel. Beams 11, 100401 (2008PRABFM1098-440210.1103/PhysRevSTAB.11.100401. The design of the improved monitor was developed using three-dimensional particle-in-cell simulations that model vacuum electron flow in the transmission line near the monitor. The simulations include important geometric features of the B-dot probe and model the deposition of electron energy within the probe. The simulations show that the improved design reduces by as much as a factor of 5 the electron energy deposition to the interior of the monitor. Data taken on accelerator shots demonstrate that the improved monitor works as well as the original monitor on shots with low-impedance loads, and delivers superior performance on higher-impedance-load shots.

  19. Effect of operational factors on bioregeneration of binary phenol and 4-chlorophenol-loaded granular activated carbon using PVA-immobilized biomass cryogels.

    Science.gov (United States)

    Leong, Kwok-Yii; Adnan, Rohana; Lim, Poh-Eng; Ng, Si-Ling; Seng, Chye-Eng

    2017-09-01

    The effects of dry biomass density in cryogel beads, shaking speed and initial concentration ratio of phenol to 4-chlorophenol (4-CP) on the bioregeneration efficiencies of binary phenol and 4-CP-loaded granular activated carbon (GAC) for phenol and 4-CP, respectively, were investigated under the simultaneous adsorption and biodegradation approach. The results revealed higher bioregeneration efficiencies of binary-loaded GAC for phenol and 4-CP at higher dry biomass density but moderate shaking speed. The optimum dry biomass density in cryogel beads and shaking speed for use in bioregeneration were found to be 0.01 g/mL and 250 rpm, respectively. With respect to the initial phenol to 4-CP concentration ratio, the bioregeneration efficiencies were lower under increasing phenol and 4-CP initial concentrations, respectively, with the effect being more conspicuous under increasing 4-CP concentration. Higher bioregeneration efficiencies were achieved with the use of immobilized rather than suspended biomasses.

  20. Low External Workloads Are Related to Higher Injury Risk in Professional Male Basketball Games

    Directory of Open Access Journals (Sweden)

    Toni Caparrós, Martí Casals, Álvaro Solana, Javier Peña

    2018-06-01

    Full Text Available The primary purpose of this study was to identify potential risk factors for sports injuries in professional basketball. An observational retrospective cohort study involving a male professional basketball team, using game tracking data was conducted during three consecutive seasons. Thirty-three professional basketball players took part in this study. A total of 29 time-loss injuries were recorded during regular season games, accounting for 244 total missed games with a mean of 16.26 ± 15.21 per player and season. The tracking data included the following variables: minutes played, physiological load, physiological intensity, mechanical load, mechanical intensity, distance covered, walking maximal speed, maximal speed, sprinting maximal speed, maximal speed, average offensive speed, average defensive speed, level one acceleration, level two acceleration, level three acceleration, level four acceleration, level one deceleration, level two deceleration, level three deceleration, level four deceleration, player efficiency rating and usage percentage. The influence of demographic characteristics, tracking data and performance factors on the risk of injury was investigated using multivariate analysis with their incidence rate ratios (IRRs. Athletes with less or equal than 3 decelerations per game (IRR, 4.36; 95% CI, 1.78-10.6 and those running less or equal than 1.3 miles per game (lower workload (IRR, 6.42 ; 95% CI, 2.52-16.3 had a higher risk of injury during games (p < 0.01 in both cases. Therefore, unloaded players have a higher risk of injury. Adequate management of training loads might be a relevant factor to reduce the likelihood of injury according to individual profiles.

  1. Loads and loads and loads: The influence of prospective load, retrospective load, and ongoing task load in prospective memory

    Directory of Open Access Journals (Sweden)

    Beat eMeier

    2015-06-01

    Full Text Available In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load can affect prospective memory performance. The existence of multiple target events increases prospective load and adding complexity to the to-be-remembered action increases retrospective load. In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of prospective load on costs in the ongoing task for categorical targets (Experiment 2, but not for specific targets (Experiment 1. Retrospective load and ongoing task load both affected remembering the retrospective component of the prospective memory task. We suggest that prospective load can enhance costs in the ongoing task due to additional monitoring requirements. Retrospective load and ongoing task load seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially.

  2. Dynamic Magnification Factor in a Box-Shape Steel Girder

    Science.gov (United States)

    Rahbar-Ranji, A.

    2014-01-01

    The dynamic effect of moving loads on structures is treated as a dynamic magnification factor when resonant is not imminent. Studies have shown that the calculated magnification factors from field measurements could be higher than the values specified in design codes. It is the main aim of present paper to investigate the applicability and accuracy of a rule-based expression for calculation of dynamic magnification factor for lifting appliances used in marine industry. A steel box shape girder of a crane is considered and transient dynamic analysis using computer code ANSYS is implemented. Dynamic magnification factor is calculated for different loading conditions and compared with rule-based equation. The effects of lifting speeds, acceleration, damping ratio and position of cargo are examined. It is found that rule-based expression underestimate dynamic magnification factor.

  3. Optimization of economic load dispatch of higher order general cost polynomials and its sensitivity using modified particle swarm optimization

    International Nuclear Information System (INIS)

    Saber, Ahmed Yousuf; Chakraborty, Shantanu; Abdur Razzak, S.M.; Senjyu, Tomonobu

    2009-01-01

    This paper presents a modified particle swarm optimization (MPSO) for constrained economic load dispatch (ELD) problem. Real cost functions are more complex than conventional second order cost functions when multi-fuel operations, valve-point effects, accurate curve fitting, etc., are considering in deregulated changing market. The proposed modified particle swarm optimization (PSO) consists of problem dependent variable number of promising values (in velocity vector), unit vector and error-iteration dependent step length. It reliably and accurately tracks a continuously changing solution of the complex cost function and no extra concentration/effort is needed for the complex higher order cost polynomials in ELD. Constraint management is incorporated in the modified PSO. The modified PSO has balance between local and global searching abilities, and an appropriate fitness function helps to converge it quickly. To avoid the method to be frozen, stagnated/idle particles are reset. Sensitivity of the higher order cost polynomials is also analyzed visually to realize the importance of the higher order cost polynomials for the optimization of ELD. Finally, benchmark data sets and methods are used to show the effectiveness of the proposed method. (author)

  4. Limit load assessment of centre cracked plates under biaxial loading

    International Nuclear Information System (INIS)

    Meek, C.; Ainsworth, R.A.

    2015-01-01

    Fitness-for-service of equipment and components containing defects is generally assessed using procedures such as BS 7910, API 579 and R6. There is currently little detailed advice in these procedures on the effects of biaxial and triaxial loading on fracture. This poster shows some theoretical bounding solutions of the plastic limit load for centre cracked plates under a variety of biaxial loading ratios and compares the estimates with those found by numerical methods using finite element (FE) analysis using Abacus CAE modelling software. The limit load of a structure is the maximum load that it can carry before plastic collapse occurs; this is often when the plastic zone has become large enough to spread from the crack tip to a remote boundary. For an elastic-perfectly plastic material, the irreversible deformation will continue at stresses no higher than the yield stress. The model for these limit load solutions is a bi-axially loaded plate of width 2W and height 2H, a centre crack of width 2a, acted on by remotely applied uniform stresses σ 2 perpendicular to the crack and Bσ 2 parallel to the crack, where B is the biaxial loading ratio, it means the ratio of the parallel to the perpendicular stress. A quarter plate of an elastic-perfectly plastic material has been modelled. The results show that an exact solution has been found for negative and low positive values of B. For B > 1, the lower bound solution is conservative for all values of a/W and B

  5. electrical load survey electrical load survey and forecast

    African Journals Online (AJOL)

    eobe

    scattered nature of the area and low load factor. In this ... employment and allow decentralized production of the ... and viable concept from energy production and .... VII Yr. ×. kWh. VIII Yr. ×. kWh. IX Yr. ×. kWh. X Yr. ×. kWh. 1. Residential. 147.

  6. The effects of centre-based rehabilitation after acute myocardial infarction on exercise capacity and risk factors for coronary heart disease

    Directory of Open Access Journals (Sweden)

    Polona Mlakar

    2014-11-01

    Full Text Available Background Rehabilitation following acute myocardial infarction (AMI is a crucial part of secondary prevention for coronary heart disease. The aim of our study was to determine the efficiency of our national in-patient rehabilitation program in improving exercise capacity and lowering risk factors for coronary heart disease.Methods 25 patients 3-9 weeks after AMI, undergoing 2 week in-patient cardiac rehabilitation, were included in our study. We performed exercise stress testing and measurement of classic risk factors before and after the rehabilitation. Classic risk factors were compared with 25 age matched adults without known risk factors for coronary heart disease.Results Patients after AMI had lower exercise capacity than healthy adults (p≤0.002 for double product, maximal load, systolic blood pressure, heart rate and time of load. Patients recieved appropriate drug therapy after myocardial infarction, which presented as lower diastolic and a trend to lower systolic blood pressure (p=0.002 and 0.080, lower total and LDL cholesterol values (both p<0.001 than healthy adults, but higher values of metabolic syndrome parameters (higher waist cifcumference p=0.045, higher hip-waist ratio, lower HDL cholesterol, both p<0.001, and a trend to higher body mass index. Although we observed significant increases in exercise capacity (higher, maximal load, systolic blood pressure,double product and time of load, all p≤0.003, no changes in classic risk factors during rehabilitaiton were demonstrated.Conclusions In-patient program of cardiac rehabilitation efficiently elevates exercise capacity in patients after AMI, but fails to influence classic risk factors for coronary heart disease, which might be due to lack of controlled cardioprotective diet during rehabilitation.

  7. Probabilistic model of bridge vehicle loads in port area based on in-situ load testing

    Science.gov (United States)

    Deng, Ming; Wang, Lei; Zhang, Jianren; Wang, Rei; Yan, Yanhong

    2017-11-01

    Vehicle load is an important factor affecting the safety and usability of bridges. An statistical analysis is carried out in this paper to investigate the vehicle load data of Tianjin Haibin highway in Tianjin port of China, which are collected by the Weigh-in- Motion (WIM) system. Following this, the effect of the vehicle load on test bridge is calculated, and then compared with the calculation result according to HL-93(AASHTO LRFD). Results show that the overall vehicle load follows a distribution with a weighted sum of four normal distributions. The maximum vehicle load during the design reference period follows a type I extremum distribution. The vehicle load effect also follows a weighted sum of four normal distributions, and the standard value of the vehicle load is recommended as 1.8 times that of the calculated value according to HL-93.

  8. Heat load of a GaAs photocathode in an SRF electron gun

    International Nuclear Information System (INIS)

    Wang Erdong; Zhao Kui; Jorg Kewisch; Ilan Ben-Zvi; Andrew Burrill; Trivini Rao; Wu Qiong; Animesh Jain; Ramesh Gupta; Doug Holmes

    2011-01-01

    A great deal of effort has been made over the last decades to develop a better polarized electron source for high energy physics. Several laboratories operate DC guns with a gallium arsenide photocathode, which yield a highly polarized electron beam. However, the beam's emittance might well be improved by using a superconducting radio frequency (SRF) electron gun, which delivers beams of a higher brightness than that from DC guns because the field gradient at the cathode is higher. SRF guns with metal and CsTe cathodes have been tested successfully. To produce polarized electrons, a Gallium-Arsenide photo-cathode must be used: an experiment to do so in a superconducting RF gun is under way at BNL. Since a bulk gallium arsenide (GaAs) photocathode is normal conducting, a problem arises from the heat load stemming from the cathode. We present our measurements of the electrical resistance of GaAs at cryogenic temperatures, a prediction of the heat load and verification by measuring the quality factor of the gun with and without the cathode at 2 K. We simulate heat generation and flow from the GaAs cathode using the ANSYS program. By following the findings with the heat load model, we designed and fabricated a new cathode holder (plug) to decrease the heat load from GaAs. (authors)

  9. Selecting boundary conditions in physiological strain analysis of the femur: Balanced loads, inertia relief method and follower load.

    Science.gov (United States)

    Heyland, Mark; Trepczynski, Adam; Duda, Georg N; Zehn, Manfred; Schaser, Klaus-Dieter; Märdian, Sven

    2015-12-01

    Selection of boundary constraints may influence amount and distribution of loads. The purpose of this study is to analyze the potential of inertia relief and follower load to maintain the effects of musculoskeletal loads even under large deflections in patient specific finite element models of intact or fractured bone compared to empiric boundary constraints which have been shown to lead to physiological displacements and surface strains. The goal is to elucidate the use of boundary conditions in strain analyses of bones. Finite element models of the intact femur and a model of clinically relevant fracture stabilization by locking plate fixation were analyzed with normal walking loading conditions for different boundary conditions, specifically re-balanced loading, inertia relief and follower load. Peak principal cortex surface strains for different boundary conditions are consistent (maximum deviation 13.7%) except for inertia relief without force balancing (maximum deviation 108.4%). Influence of follower load on displacements increases with higher deflection in fracture model (from 3% to 7% for force balanced model). For load balanced models, follower load had only minor influence, though the effect increases strongly with higher deflection. Conventional constraints of fixed nodes in space should be carefully reconsidered because their type and position are challenging to justify and for their potential to introduce relevant non-physiological reaction forces. Inertia relief provides an alternative method which yields physiological strain results. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Fisher Information Based Meteorological Factors Introduction and Features Selection for Short-Term Load Forecasting

    Directory of Open Access Journals (Sweden)

    Shuping Cai

    2018-03-01

    Full Text Available Weather information is an important factor in short-term load forecasting (STLF. However, for a long time, more importance has always been attached to forecasting models instead of other processes such as the introduction of weather factors or feature selection for STLF. The main aim of this paper is to develop a novel methodology based on Fisher information for meteorological variables introduction and variable selection in STLF. Fisher information computation for one-dimensional and multidimensional weather variables is first described, and then the introduction of meteorological factors and variables selection for STLF models are discussed in detail. On this basis, different forecasting models with the proposed methodology are established. The proposed methodology is implemented on real data obtained from Electric Power Utility of Zhenjiang, Jiangsu Province, in southeast China. The results show the advantages of the proposed methodology in comparison with other traditional ones regarding prediction accuracy, and it has very good practical significance. Therefore, it can be used as a unified method for introducing weather variables into STLF models, and selecting their features.

  11. Children's Emotionality Moderates the Association Between Maternal Responsiveness and Allostatic Load: Investigation Into Differential Susceptibility.

    Science.gov (United States)

    Dich, Nadya; Doan, Stacey N; Evans, Gary W

    2015-01-01

    While emotionality is often thought of as a risk factor, differential susceptibility theory argues that emotionality reflects susceptibility to both positive and negative environmental influences. The present study explored whether emotional children might be more susceptible to the effects of both high and low maternal responsiveness on allostatic load, a physiological indicator of chronic stress. Participants were 226 mother and child dyads. Mothers reported on children's emotionality at child age 9. Maternal responsiveness was measured at age 13 using self-reports and behavioral observation. Allostatic load was measured at age 13 and 17 using neuroendocrine, cardiovascular, and metabolic biomarkers. Emotionality was associated with higher allostatic load if self-reported responsiveness was low, but with lower allostatic load, when self-reported responsiveness was high. © 2015 The Authors. Child Development © 2015 Society for Research in Child Development, Inc.

  12. Factors affecting the potential of direct load control for non-generating utilities. Final report. [Distribution and wholesale power supply interaction

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-04-01

    Several alternatives are available for achieving load management, including direct or voluntary control of customer loads, customer or utility energy storage systems for diurnal load shifting, and expanded interconnection and operation of electric power systems. All of these alternatives are available to the fully integrated (generating, transmitting and distributing) electric utility and the analysis of their effects encompasses the power supply and delivery system. However, the costs and benefits of the alternatives to the fully integrated electric utility are perhaps not so obvious. Therefore, by considering a non-generating utility, this analysis focuses upon the distribution system and wholesale power supply interaction as a step toward an analysis including the power supply and delivery system. This report develops an analysis procedure and discusses some of the relevant factors to be consdered in the application of direct load control for a non-generating utility system. The analysis concentrates on the distribution system only to determine the effect of rates and payback as a result of direct load control. Thus, the study is responsive to the specific needs of the non-generating utility. This analysis of direct load control encompasses the determination of those loads amenable to control, the selection of a suitable one-way communications system to rend control and the estimation of expected benefits and costs. The complementary functions to the application of direct load control such as automatic meter reading via the addition of a bi-directional communications system and voltage control are not included in the analysis but are detailed for future consideration.

  13. An analysis of representative heating load lines for residential HSPF ratings

    Energy Technology Data Exchange (ETDEWEB)

    Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shrestha, Som S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-07-01

    This report describes an analysis to investigate representative heating loads for single-family detached homes using current EnergyPlus simulations (DOE 2014a). Hourly delivered load results are used to determine binned load lines using US Department of Energy (DOE) residential prototype building models (DOE 2014b) developed by Pacific Northwest National Laboratory (PNNL). The selected residential single-family prototype buildings are based on the 2006 International Energy Conservation Code (IECC 2006) in the DOE climate regions. The resulting load lines are compared with the American National Standards Institute (ANSI)/Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Standard 210/240 (AHRI 2008) minimum and maximum design heating requirement (DHR) load lines of the heating seasonal performance factor (HSPF) ratings procedure for each region. The results indicate that a heating load line closer to the maximum DHR load line, and with a lower zero load ambient temperature, is more representative of heating loads predicted for EnergyPlus prototype residential buildings than the minimum DHR load line presently used to determine HSPF ratings. An alternative heating load line equation was developed and compared to binned load lines obtained from the EnergyPlus simulation results. The effect on HSPF of the alternative heating load line was evaluated for single-speed and two-capacity heat pumps, and an average HSPF reduction of 16% was found. The alternative heating load line relationship is tied to the rated cooling capacity of the heat pump based on EnergyPlus autosizing, which is more representative of the house load characteristics than the rated heating capacity. The alternative heating load line equation was found to be independent of climate for the six DOE climate regions investigated, provided an adjustable zero load ambient temperature is used. For Region IV, the default DOE climate region used for HSPF ratings, the higher load line results in an ~28

  14. Modification of the ASME code z-factor for circumferential surface crack in nuclear ferritic pipings

    International Nuclear Information System (INIS)

    Choi, Young Hwan; Chung, Yon Ki; Koh, Wan Young; Lee, Joung Bae

    1996-01-01

    The purpose of this paper is to modify the ASME Code Z-Factor, which is used in the evaluation of circumferential surface crack in nuclear ferritic pipings. The ASME Code Z-Factor is a load multiplier to compensate plastic load with elasto-plastic load. The current ASME Code Z-Factor underestimates pipe maximum load. In this study, the original SC. TNP method is modified first because the original SC. TNP method has a problem that the maximum allowable load predicted from the original SC. TNP method is slightly higher than that measured from the experiment. Then the new Z-Factor is developed using the modified SC. TNP method. The desirability of both the modified SC. TNP method and the new Z-Factor is examined using the experimental results for the circumferential surface crack in pipings. The results show that (1) the modified SC. TNP method is good for predicting the circumferential surface crack behavior in pipings, and (2) the Z-Factor obtained from the modified SC. TNP method well predicts the behavior of circumferential surface crack in ferritic pipings. 30 refs., 13 figs., 4 tabs. (author)

  15. Cognitive Load Alters Neuronal Processing of Food Odors.

    Science.gov (United States)

    Hoffmann-Hensel, Sonja Maria; Sijben, Rik; Rodriguez-Raecke, Rea; Freiherr, Jessica

    2017-10-31

    Obesity is a major health concern in modern societies. Although decreased physical activity and enhanced intake of high-caloric foods are important risk factors for developing obesity, human behavior during eating also plays a role. Previous studies have shown that distraction while eating increases food intake and leads to impaired processing of food stimuli. As olfaction is the most important sense involved in flavor perception, we used functional magnetic resonance imaging techniques to investigate the influence of cognitive memory load on olfactory perception and processing. Low- and high-caloric food odors were presented in combination with either low or high cognitive loads utilizing a memory task. The efficacy of the memory task was verified by a decrease in participant recall accuracy and an increase in skin conductance response during high cognitive load. Our behavioral data reveal a diminished perceived intensity for low- but not high-caloric food odors during high cognitive load. For low-caloric food odors, bilateral orbitofrontal (OFC) and piriform cortices (pirC) showed significantly lower activity during high compared with low cognitive load. For high-caloric food odors, a similar effect was established in pirC, but not in OFC. Insula activity correlates with higher intensity ratings found during the low cognitive load condition. We conclude lower activity in pirC and OFC to be responsible for diminished intensity perception, comparable to results in olfactory impaired patients and elderly. Further studies should investigate the influence of olfactory/gustatory intensities on food choices under distraction with special regards to low-caloric food. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Daily Air Temperature and Electricity Load in Spain.

    Science.gov (United States)

    Valor, Enric; Meneu, Vicente; Caselles, Vicente

    2001-08-01

    Weather has a significant impact on different sectors of the economy. One of the most sensitive is the electricity market, because power demand is linked to several weather variables, mainly the air temperature. This work analyzes the relationship between electricity load and daily air temperature in Spain, using a population-weighted temperature index. The electricity demand shows a significant trend due to socioeconomic factors, in addition to daily and monthly seasonal effects that have been taken into account to isolate the weather influence on electricity load. The results indicate that the relationship is nonlinear, showing a `comfort interval' of ±3°C around 18°C and two saturation points beyond which the electricity load no longer increases. The analysis has also revealed that the sensitivity of electricity load to daily air temperature has increased along time, in a higher degree for summer than for winter, although the sensitivity in the cold season is always more significant than in the warm season. Two different temperature-derived variables that allow a better characterization of the observed relationship have been used: the heating and cooling degree-days. The regression of electricity data on them defines the heating and cooling demand functions, which show correlation coefficients of 0.79 and 0.87, and predicts electricity load with standard errors of estimate of ±4% and ±2%, respectively. The maximum elasticity of electricity demand is observed at 7 cooling degree-days and 9 heating degree-days, and the saturation points are reached at 11 cooling degree-days and 13 heating degree-days, respectively. These results are helpful in modeling electricity load behavior for predictive purposes.

  17. Response of inherently brittle materials on higher loading rates

    Czech Academy of Sciences Publication Activity Database

    Chlup, Zdeněk; Flašar, Petr; Dlouhý, Ivo

    2010-01-01

    Roč. 77, č. 2 (2010), s. 359-366 ISSN 0013-7944 R&D Projects: GA ČR GA101/09/1821; GA AV ČR IAA200410502 Institutional research plan: CEZ:AV0Z20410507 Keywords : Dynamic fracture toughness * Stress intensity factor * Ceramics Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 1.571, year: 2010

  18. Higher-moment stochastic discount factor specifications and the cross-section of asset returns

    OpenAIRE

    Wang, Dengli

    2013-01-01

    The stochastic discount factor model provides a general framework for pricing assets. A suitably specified discount factor encompasses most of the theories currently in use, including the CAPM, consumption CAPM, higher-moment CAPM and their conditional versions. In this thesis, we focus on the empirical admissibility of alternative SDFs under restrictions that ensure that investors’ risk-preferences are well behaved. More innovatively, we explore whether the SDF implied by the 3 and 4-mome...

  19. Influence of squeeze film damping on the higher-order modes of clamped–clamped microbeams

    KAUST Repository

    Alcheikh, Nouha

    2016-05-06

    This paper presents an experimental study and a finite-element analysis of the effect of squeeze film damping on the resonance frequency and quality factor of the higher-order flexure vibrations modes of clamped-clamped microbeams. Viscoelastic and silicon nitride microbeams are fabricated and are electrostatically actuated by various electrode configurations to trigger the first, second, and third modes. The damping characteristic and the resonance frequency of these modes are examined for a wide range of gas pressure and electrostatic voltage loads. The results of the silicon nitride beams and viscoelastic beams are compared. It is found that the intrinsic material loss is the major dissipation mechanism at low pressure for the viscoelastic microbeams, significantly limiting their quality factor. It is also found that while the silicon nitride beams show higher quality factors at the intrinsic and molecular regimes of pressure, due to their low intrinsic loss, their quality factors near atmospheric pressure are lower than those of the viscoelastic microbeams. Further, the higher-order modes of all the beams show much higher quality factors at atmospheric pressure compared to the first mode, which could be promising for operating such resonators in air. Experimental results and finite element model simulations show good agreement for resonance frequency and quality factor for the three studied modes. © 2016 IOP Publishing Ltd.

  20. Protein growth factors loaded highly porous chitosan scaffold: A comparison of bone healing properties

    International Nuclear Information System (INIS)

    Nandi, Samit K.; Kundu, Biswanath; Basu, Debabrata

    2013-01-01

    Present study aimed to investigate and compare effectiveness of porous chitosan alone and in combination with insulin like growth factor-1 (IGF-1) and bone morphogenetic protein-2 (BMP-2) in bone healing. Highly porous (85 ± 2%) with wide distribution of macroporous (70–900 μm) chitosan scaffolds were fabricated as bone substitutes by employing a simple liquid hardening method using 2% (w/v) chitosan suspension. IGF-1 and BMP-2 were infiltrated using vacuum infiltration with freeze drying method. Adsorption efficiency was found to be 87 ± 2 and 90 ± 2% for BMP-2 and IGF-1 respectively. After thorough material characterization (pore details, FTIR and SEM), samples were used for subsequent in vivo animal trial. Eighteen rabbit models were used to evaluate and compare control (chitosan) (group A), chitosan with IGF-1 (group B) and chitosan with BMP-2 (group C) in the repair of critical size bone defect in tibia. Radiologically, there was evidence of radiodensity in defect area from 60th day (initiated on 30th day) in groups B and C as compared to group A and attaining nearly bony density in most of the part at day 90. Histological results depicted well developed osteoblastic proliferation around haversian canal along with proliferating fibroblast, vascularization and reticular network which was more pronounced in group B followed by groups C and A. Fluorochrome labeling and SEM studies in all groups showed similar outcome. Hence, porous chitosan alone and in combination with growth factors (GFs) can be successfully used for bone defect healing with slight advantage of IGF-1 in chitosan samples. - Highlights: ► Fabrication and characterization of porous chitosan with or without IGF-1 and BMP-2 ► Highly porous growth factor loaded chitosan studied in animal subjects for 3 months ► Parameters studied: histopathology, radiology and fluorochrome labeling ► IGF-1 loaded porous chitosan found to be very effective for bone defect healing

  1. Protein growth factors loaded highly porous chitosan scaffold: A comparison of bone healing properties

    Energy Technology Data Exchange (ETDEWEB)

    Nandi, Samit K., E-mail: samitnandi1967@gmail.com [Department of Veterinary Surgery and Radiology, West Bengal University of Animal and Fishery Sciences, Kolkata (India); Kundu, Biswanath, E-mail: biswa_kundu@rediffmail.com [Bioceramics and Coating Division, CSIR—Central Glass and Ceramic Research Institute, Kolkata (India); Basu, Debabrata [Bioceramics and Coating Division, CSIR—Central Glass and Ceramic Research Institute, Kolkata (India)

    2013-04-01

    Present study aimed to investigate and compare effectiveness of porous chitosan alone and in combination with insulin like growth factor-1 (IGF-1) and bone morphogenetic protein-2 (BMP-2) in bone healing. Highly porous (85 ± 2%) with wide distribution of macroporous (70–900 μm) chitosan scaffolds were fabricated as bone substitutes by employing a simple liquid hardening method using 2% (w/v) chitosan suspension. IGF-1 and BMP-2 were infiltrated using vacuum infiltration with freeze drying method. Adsorption efficiency was found to be 87 ± 2 and 90 ± 2% for BMP-2 and IGF-1 respectively. After thorough material characterization (pore details, FTIR and SEM), samples were used for subsequent in vivo animal trial. Eighteen rabbit models were used to evaluate and compare control (chitosan) (group A), chitosan with IGF-1 (group B) and chitosan with BMP-2 (group C) in the repair of critical size bone defect in tibia. Radiologically, there was evidence of radiodensity in defect area from 60th day (initiated on 30th day) in groups B and C as compared to group A and attaining nearly bony density in most of the part at day 90. Histological results depicted well developed osteoblastic proliferation around haversian canal along with proliferating fibroblast, vascularization and reticular network which was more pronounced in group B followed by groups C and A. Fluorochrome labeling and SEM studies in all groups showed similar outcome. Hence, porous chitosan alone and in combination with growth factors (GFs) can be successfully used for bone defect healing with slight advantage of IGF-1 in chitosan samples. - Highlights: ► Fabrication and characterization of porous chitosan with or without IGF-1 and BMP-2 ► Highly porous growth factor loaded chitosan studied in animal subjects for 3 months ► Parameters studied: histopathology, radiology and fluorochrome labeling ► IGF-1 loaded porous chitosan found to be very effective for bone defect healing.

  2. Load Estimation from Natural input Modal Analysis

    DEFF Research Database (Denmark)

    Aenlle, Manuel López; Brincker, Rune; Canteli, Alfonso Fernández

    2005-01-01

    One application of Natural Input Modal Analysis consists in estimating the unknown load acting on structures such as wind loads, wave loads, traffic loads, etc. In this paper, a procedure to determine loading from a truncated modal model, as well as the results of an experimental testing programme...... estimation. In the experimental program a small structure subjected to vibration was used to estimate the loading from the measurements and the experimental modal space. The modal parameters were estimated by Natural Input Modal Analysis and the scaling factors of the mode shapes obtained by the mass change...

  3. Measuring cognitive load during procedural skills training with colonoscopy as an exemplar.

    Science.gov (United States)

    Sewell, Justin L; Boscardin, Christy K; Young, John Q; Ten Cate, Olle; O'Sullivan, Patricia S

    2016-06-01

    Few studies have investigated cognitive factors affecting learning of procedural skills in medical education. Cognitive load theory, which focuses on working memory, is highly relevant, but methods for measuring cognitive load during procedural training are not well understood. Using colonoscopy as an exemplar, we used cognitive load theory to develop a self-report instrument to measure three types of cognitive load (intrinsic, extraneous and germane load) and to provide evidence for instrument validity. We developed the instrument (the Cognitive Load Inventory for Colonoscopy [CLIC]) using a multi-step process. It included 19 items measuring three types of cognitive load, three global rating items and demographics. We then conducted a cross-sectional survey that was administered electronically to 1061 gastroenterology trainees in the USA. Participants completed the CLIC following a colonoscopy. The two study phases (exploratory and confirmatory) each lasted for 10 weeks during the 2014-2015 academic year. Exploratory factor analysis determined the most parsimonious factor structure; confirmatory factor analysis assessed model fit. Composite measures of intrinsic, extraneous and germane load were compared across years of training and with global rating items. A total of 477 (45.0%) invitees participated (116 in the exploratory study and 361 in the confirmatory study) in 154 (95.1%) training programmes. Demographics were similar to national data from the USA. The most parsimonious factor structure included three factors reflecting the three types of cognitive load. Confirmatory factor analysis verified that a three-factor model was the best fit. Intrinsic, extraneous and germane load items had high internal consistency (Cronbach's alpha 0.90, 0.87 and 0.96, respectively) and correlated as expected with year in training and global assessment of cognitive load. The CLIC measures three types of cognitive load during colonoscopy training. Evidence of validity is

  4. Factors Affecting Female Lecturer Retention in Private Higher Institution in Perak

    OpenAIRE

    Juliana Abu Bakar; Zam Zuriyati Mohamad; S.A. Sharmeela-Banu

    2015-01-01

    The contribution of female lecturer in education profession is undeniable and their satisfaction is crucial to retain them in this field. This research was conducted with the aim to investigate the factors that influence the female lecturer satisfaction in private higher education institution in Perak, Malaysia. Subsequently it intends to examine the effect of female lecturer satisfaction on their job retention. Perceived Organization Support Theory and Theory of Organizational Equilibrium ha...

  5. Related factors to atazanavir plasma levels in a cohort of HIV positive individuals with undetectable viral load

    Directory of Open Access Journals (Sweden)

    Ana Júlia Luz

    Full Text Available OBJECTIVE: To evaluate the factors associated with plasma concentrations of atazanavir (ATV in a cohort of well-controlled HIV infected subjects (undetectable viremia. Design: Cross-sectional study where 69 subjects were consecutively enrolled between April and November, 2011. METHODS: Patients had to be on atazanavir for at least six months, undetectable viral load for a period equal to or longer than 12 months, T CD4+ lymphocyte count higher than 200 cells/mm³, and aged between 18 years and 70 years old. Exclusion criteria were pregnancy, any neurologic disease, active opportunistic disease, hepatitis or cancer. Atazanavir plasma levels were measured by ultra-performance liquid chromatography. RESULTS AND DISCUSSION: Overall, 54 patients (mean age of 47 years and 50% women were included in the analysis. Those without ritonavir (unboosted atazanavir had statistically lower plasma concentrations than those with ritonavir boosted atazanavir (p = 0.001 and total and indirect bilirubin were statistically associated with plasma concentration of atazanavir (r = 0.32 and r = 0.33 respectively; p < 0.05 in both cases. no statistical association was found among gender, ethnicity, age, weight, body mass index (BMI, lipid profile, and the plasma concentration of atazanavir. CONCLUSION: in summary, as expected, concomitant ritonavir use was the only factor associated with atazanavir plasma levels. prospective studies with a larger sample size might help to observe an association of atazanavir concentrations to other characteristics such as body weight, since the p-value showed to be close to significance (p = 0.068.

  6. Evaluation of self-assembled HCPT-loaded PEG-b-PLA nanoparticles by comparing with HCPT-loaded PLA nanoparticles.

    Science.gov (United States)

    Yang, Xiangrui; Wu, Shichao; Wang, Yange; Li, Yang; Chang, Di; Luo, Yin; Ye, Shefang; Hou, Zhenqing

    2014-12-01

    We present a dialysis technique to prepare the 10-hydroxycamptothecin (HCPT)-loaded nanoparticles (NPs) using methoxypolyethylene glycol-poly(D,L-lactide) (PEG-b-PLA) and PLA, respectively. Both HCPT-loaded PEG-b-PLA NPs and HCPT-loaded PLA NPs were characterized by differential scanning calorimetry (DSC), dynamic light scattering (DLS), transmission electron microscopy (TEM), scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM). The results showed that the HCPT-loaded PEG-b-PLA NPs and HCPT-loaded PLA NPs presented a hydrodynamic particle size of 120.1 and 226.8 nm, with a polydispersity index of 0.057 and 0.207, a zeta potential of -31.2 and -45.7 mV, drug encapsulation efficiency of 44.52% and 44.94%, and drug-loaded content of 7.42% and 7.49%, respectively. The HCPT-loaded PEG-b-PLA NPs presented faster drug release rate compared to the HCPT-loaded PLA NPs. The HCPT-loaded PEG-b-PLA NPs presented higher cytotoxicity than the HCPT-loaded PLA NPs. These results suggested that the HCPT-loaded PEG-b-PLA NPs presented better characteristics for drug delivery compared to HCPT-loaded PLA NPs.

  7. Identifying Factors That Affect Higher Educational Achievements of Jamaican Seventh-Day Adventists

    Science.gov (United States)

    Campbell, Samuel P.

    2011-01-01

    This mixed-method explanatory research examined factors that influenced Jamaican Seventh-day Adventist (SDA) members to pursue higher education. It sought to investigate whether the source of the motivation is tied to the Church's general philosophy on education or to its overall programs as experienced by the membership at large. The question of…

  8. Human Factors Evaluation of the Modular Lightweight Load-Carrying Equipment (MOLLE) System

    National Research Council Canada - National Science Library

    Sampson, James

    2001-01-01

    .... The FEA was used in drafting a new user requirements document and initiating the development of a modular load-carrying system which ultimately became known as the Modular Lightweight Load-carrying Equipment (MOLLE...

  9. Utilization of Plutonium and Higher Actinides in the HTGR as Possibility to Maintain Long-Term Operation on One Fuel Loading

    International Nuclear Information System (INIS)

    Tsvetkova, Galina V.; Peddicord, Kenneth L.

    2002-01-01

    Promising existing nuclear reactor concepts together with new ideas are being discussed worldwide. Many new studies are underway in order to identify prototypes that will be analyzed and developed further as systems for Generation IV. The focus is on designs demonstrating full inherent safety, competitive economics and proliferation resistance. The work discussed here is centered on a modularized small-size High Temperature Gas-cooled Reactor (HTGR) concept. This paper discusses the possibility of maintaining long-term operation on one fuel loading through utilization of plutonium and higher actinides in the small-size pebble-bed reactor (PBR). Acknowledging the well-known flexibility of the PBR design with respect to fuel composition, the principal limitations of the long-term burning of plutonium and higher actinides are considered. The technological challenges and further research are outlined. The results allow the identification of physical features of the PBR that significantly influence flexibility of the design and its applications. (authors)

  10. Are Fit Indices Biased in Favor of Bi-Factor Models in Cognitive Ability Research?: A Comparison of Fit in Correlated Factors, Higher-Order, and Bi-Factor Models via Monte Carlo Simulations

    Directory of Open Access Journals (Sweden)

    Grant B. Morgan

    2015-02-01

    Full Text Available Bi-factor confirmatory factor models have been influential in research on cognitive abilities because they often better fit the data than correlated factors and higher-order models. They also instantiate a perspective that differs from that offered by other models. Motivated by previous work that hypothesized an inherent statistical bias of fit indices favoring the bi-factor model, we compared the fit of correlated factors, higher-order, and bi-factor models via Monte Carlo methods. When data were sampled from a true bi-factor structure, each of the approximate fit indices was more likely than not to identify the bi-factor solution as the best fitting. When samples were selected from a true multiple correlated factors structure, approximate fit indices were more likely overall to identify the correlated factors solution as the best fitting. In contrast, when samples were generated from a true higher-order structure, approximate fit indices tended to identify the bi-factor solution as best fitting. There was extensive overlap of fit values across the models regardless of true structure. Although one model may fit a given dataset best relative to the other models, each of the models tended to fit the data well in absolute terms. Given this variability, models must also be judged on substantive and conceptual grounds.

  11. Stress concentration factors for integral and pad reinforced nozzles in spherical pressure vessels subjected to radial load and moment

    International Nuclear Information System (INIS)

    Soliman, S.F.; Gill, S.S.

    1979-01-01

    Charts are presented giving the elastic stress concentration factors in spherical pressure vessels with pad and integral reinforcement for radial branches subjected to radial load and moment. The effect of all the geometrical parameters is discussed, including the limitations of thin shell theory on the validity of the results. (author)

  12. The stress and stress intensity factors computation by BEM and FEM combination for nozzle junction under pressure and thermal loads

    International Nuclear Information System (INIS)

    Du, Q.; Cen, Z.; Zhu, H.

    1989-01-01

    This paper reports linear elastic fracture analysis based upon the stress intensity factor evaluation successfully applied to safety assessments of cracked structures. The nozzle junction are usually subjected to high pressure and thermal loads simultaneously. In validity of linear elastic fracture analysis, K can be decomposed into K P (caused by mechanic loads) and K τ (caused by thermal loads). Under thermal transient loading, explicit analysis (say by the FEM or BEM) of K tracing an entire history respectively for a range of crack depth may be much more time consuming. The techniques of weight function provide efficient means for transforming the problem into the stress computation of the uncracked structure and generation of influence function (for the given structure and size of crack). In this paper, a combination of BE-FEM has been used for the analysis of the cracked nozzle structure by techniques of weight function. The influence functions are obtained by coupled BE-FEM and the uncracked structure stress are computed by finite element methods

  13. Quantitative molecular viral loads in 7 horses with naturally occurring equine herpesvirus-1 infection.

    Science.gov (United States)

    Estell, K E; Dawson, D R; Magdesian, K G; Swain, E; Laing, S T; Siso, S; Mapes, S; Pusterla, N

    2015-11-01

    Data associating quantitative viral load with severity, clinical signs and survival in equine herpesvirus-1 myeloencephalopathy (EHM) have not been reported. To report the clinical signs, treatment, and temporal progression of viral loads in 7 horses with naturally occurring EHM and to examine the association of these factors with survival. Retrospective case series. The population included 7 horses with EHM presented to the University of California, Davis William R. Pritchard Veterinary Medical Teaching Hospital from May to September 2011. Horses were graded using a neurological grading scale. Daily quantitative PCR was performed on nasal secretions and whole blood. Treatment, survival, outcome and histopathology were reported. At presentation, one horse was neurological grade 5/5, 3 were grade 4/5 and 3 were grade 3/5. All were treated with anti-inflammatory drugs, valacyclovir and management in a sling if necessary. All were infected with equine herpesvirus-1 of DNA polymerase D752 genotype. Peak viral load in nasal secretions and blood of 5 survivors ranged from 6.9 × 10(3) to 2.81 × 10(5) (median 5.11 × 10(4) ) and from 143 to 4340 gB gene copies/million eukaryotic cells (median 3146), respectively. The 2 nonsurvivors presented with grade 3/5 neurological signs and progressed to encephalopathy. Peak viral load was higher in nonsurvivors, with levels in nasal secretions of 1.9 × 10(9) and 2.2 × 10(9) and in blood of 2.05 × 10(4) and 1.02 × 10(5) gB gene copies/million eukaryotic cells. Case fatality was 2/7. Nonsurvivors had viral loads 1000-fold higher in nasal secretions and 10-fold higher in blood than survivors. There was no relationship between severity of clinical signs at presentation and survival. Thus, encephalopathy and high viral load were negatively associated with survival in this population. Further research should be performed to determine whether high viral loads are associated with encephalopathy and poor prognosis. The Summary is

  14. Behaviour of eggshell membranes at tensile loading

    Czech Academy of Sciences Publication Activity Database

    Strnková, M.J.; Nedomová, Š.; Trnka, Jan; Buchar, J.; Kumbár, V.

    46 B, December (2014), s. 44-48 ISSN 0324-1130 Institutional support: RVO:61388998 Keywords : eggshell membrane * tensile loading * loading rate * stress * strain strength Subject RIV: GM - Food Processing Impact factor: 0.201, year: 2014

  15. Dry Eye Disease Patients with Xerostomia Report Higher Symptom Load and Have Poorer Meibum Expressibility.

    Science.gov (United States)

    Fostad, Ida G; Eidet, Jon R; Utheim, Tor P; Ræder, Sten; Lagali, Neil S; Messelt, Edvard B; Dartt, Darlene A

    2016-01-01

    The purpose of the study was to investigate if xerostomia (dry mouth) is associated with symptoms and signs of dry eye disease (DED). At the Norwegian Dry Eye Clinic, patients with symptomatic DED with different etiologies were consecutively included in the study. The patients underwent a comprehensive ophthalmological work-up and completed self-questionnaires on symptoms of ocular dryness (Ocular Surface Disease Index [OSDI] and McMonnies Dry Eye Questionnaire) and the Sjögren's syndrome (SS) questionnaire (SSQ). Three hundred and eighteen patients (52% women and 48% men) with DED were included. Patient demographics were: 0 to 19 years (1%), 20 to 39 (25%), 40 to 59 (34%), 60 to 79 (35%) and 80 to 99 (5%). Xerostomia, defined as "daily symptoms of dry mouth the last three months" (as presented in SSQ) was reported by 23% of the patients. Female sex was more common among patients with xerostomia (81%) than among non-xerostomia patients (44%; Pxerostomia (60 ± 15 years) were older than those without xerostomia (51 ± 17; Pxerostomia patients (65%) than among non-xerostomia patients (35%; Pxerostomia had a higher OSDI score (19.0 ± 10.0) than those without xerostomia (12.9 ± 8.0; Pxerostomia patients had more pathological meibum expressibility (0.9 ± 0.7) than those without xerostomia (0.7 ± 0.8; P = 0.046). Comparisons of OSDI and ocular signs were performed after controlling for the effects of sex, age and the number of systemic prescription drugs used. In conclusion, xerostomia patients demonstrated a higher DED symptom load and had poorer meibum expressibility than non-xerostomia patients.

  16. Facile Synthesis of Curcumin-Loaded Starch-Maleate Nanoparticles

    Directory of Open Access Journals (Sweden)

    Suh Cem Pang

    2014-01-01

    Full Text Available We have demonstrated the loading of curcumin onto starch maleate (SM under mild conditions by mixing dissolved curcumin and SM nanoparticles separately in absolute ethanol and ethanol/aqueous (40 : 60 v/v, respectively. Curcumin-loaded starch-maleate (CurSM nanoparticles were subsequently precipitated from a homogeneous mixture of these solutions in absolute ethanol based on the solvent exchange method. TEM analysis indicated that the diameters of CurSM nanoparticles were ranged between 30 nm and 110 nm with a mean diameter of 50 nm. The curcumin loading capacity of SM as a function of loading duration was investigated using the UV-visible spectrophotometer. The loading of curcumin onto SM increased rapidly initially with loading duration, and the curcumin loading capacity of 15 mg/g was reached within 12 hours. CurSM nanoparticles exhibited substantially higher water solubility of 6.0 × 10−2 mg/mL which is about 300 times higher than that of pure curcumin. With enhanced water solubility and bioaccessibility of curcumin, the potential utility of CurSM nanoparticles in various biomedical applications is therefore envisaged.

  17. Factors associated with higher levels of depressive symptoms among international university students in the Philippines.

    Science.gov (United States)

    Lee, Romeo B; Maria, Madelene Sta; Estanislao, Susana; Rodriguez, Cristina

    2013-11-01

    Over the years, the number of international university students has been increasing in the Philippines. Depression tends to be common among this demographic sector, because of the varying challenges and expectations associated with studying abroad. Depression can be prevented if its symptoms, particularly those at higher levels, are identified and addressed early and effectively. This survey examined the social and demographic factors that are significantly associated with higher levels of depressive symptoms. One hundred twenty-six international university students were interviewed using the University Students Depression Inventory. Of the 13 factors analyzed, 3 were found with statistically significant associations with more intense levels of depressive symptoms. These factors were: level of satisfaction with one's financial condition, level of closeness with parents, and level of closeness with peers. In identifying international students with greater risk for depression, characteristics related to their financial condition and primary group relationships can be considered. There is a need to carry out more studies to confirm this initial evidence. The findings can help guide further discourse, research and program to benefit international students with higher levels of depressive symptoms.

  18. Factors that Impact Quality of E-Teaching/Learning Technologies in Higher Education

    Science.gov (United States)

    Daukilas, Sigitas; Kaciniene, Irma; Vaisnoriene, Daiva; Vascila, Vytautas

    2008-01-01

    The article analyzes and assesses factors that have impact upon the quality of eTeaching/learning technologies in higher education; it is on their basis that the concept of eTeaching/learning quality is denied. Research data about the students' motives in choosing various teaching/learning technologies for the development of their competence are…

  19. Radiation Load of Children by Chest Radiodiagnostic Measurements

    International Nuclear Information System (INIS)

    Nikodemova, D.; Vladar, M.; Ranogajec-Komor, M.; Horvathova, M.

    1998-01-01

    Radiodiagnostic examinations of children present particular importance from the radiation hygiene point of view. The estimation of the radiation load of pediatric patient is not easy, because of the lack of information about organ weighting factors for various ages of patients, as well as due to the differences in applied X-ray examination parameters. In the district of Slovak Republic, in which also the working Nuclear Power Plant Jaslovske Bohunice is included, efforts were done to estimate the radiation load of children to 15 years by chest radiodiagnostic examinations. The data of entrance surface doses were collected using measurements with TLD for 100 patients divided in 5 age categories at six radiodiagnostic departments. The calculations of the total absorbed dose were performed using the measured ESD values (entrance surface dose in mGy) integrated over the X-ray beam area, the conversion factors between the imparted energy and the dose-area product and the known irradiation parameters (kV, HVL, mass, etc.). The analysis of the obtained absorbed doses (E a ) as a function of age for chest PA radiodiagnostic examinations has shown, that the investigated Slovak radiodiagnostic centres use rather lower voltage techniques and the entrance surface doses are much higher than the proposed value of European Communities. (author)

  20. A short-term load forecasting model of natural gas based on optimized genetic algorithm and improved BP neural network

    International Nuclear Information System (INIS)

    Yu, Feng; Xu, Xiaozhong

    2014-01-01

    Highlights: • A detailed data processing will make more accurate results prediction. • Taking a full account of more load factors to improve the prediction precision. • Improved BP network obtains higher learning convergence. • Genetic algorithm optimized by chaotic cat map enhances the global search ability. • The combined GA–BP model improved by modified additional momentum factor is superior to others. - Abstract: This paper proposes an appropriate combinational approach which is based on improved BP neural network for short-term gas load forecasting, and the network is optimized by the real-coded genetic algorithm. Firstly, several kinds of modifications are carried out on the standard neural network to accelerate the convergence speed of network, including improved additional momentum factor, improved self-adaptive learning rate and improved momentum and self-adaptive learning rate. Then, it is available to use the global search capability of optimized genetic algorithm to determine the initial weights and thresholds of BP neural network to avoid being trapped in local minima. The ability of GA is enhanced by cat chaotic mapping. In light of the characteristic of natural gas load for Shanghai, a series of data preprocessing methods are adopted and more comprehensive load factors are taken into account to improve the prediction accuracy. Such improvements facilitate forecasting efficiency and exert maximum performance of the model. As a result, the integration model improved by modified additional momentum factor gets more ideal solutions for short-term gas load forecasting, through analyses and comparisons of the above several different combinational algorithms

  1. Achilles and Patellar Tendinopathy Loading Programmes

    DEFF Research Database (Denmark)

    Malliaras, Peter; Barton, Christian J; Reeves, Neil D

    2013-01-01

    . Eccentric-concentric progressing to eccentric (Silbernagel combined) and eccentric-concentric isotonic (heavy-slow resistance; HSR) loading have also been investigated. In order for clinicians to make informed decisions, they need to be aware of the loading options and comparative evidence. The mechanisms...... mechanism that was consistently associated with improved clinical outcomes in both Achilles and patellar tendon rehabilitation was improved neuromuscular performance (e.g. torque, work, endurance), and Silbernagel-combined (Achilles) HSR loading (patellar) had an equivalent or higher level of evidence than...... isolated eccentric loading. In the Achilles tendon, a majority of studies did not find an association between improved imaging (e.g. reduced anteroposterior diameter, proportion of tendons with Doppler signal) and clinical outcomes, including all high-quality studies. In contrast, HSR loading...

  2. THE STRENGTH OF REINFORCED CONCRETE BEAM ELEMENTS UNDER CYCLIC ALTERNATING LOADING AND LOW CYCLE LOAD OF CONSTANT SIGN

    Directory of Open Access Journals (Sweden)

    Semina Yuliya Anatol'evna

    2015-09-01

    Full Text Available The behavior of reinforced concrete elements under some types of cyclic loads is described in the paper. The main aim of the investigations is research of the stress-strain state and strength of the inclined sections of reinforced concrete beam elements in conditions of systemic impact of constructive factors and the factor of external influence. To spotlight the problem of cyclic loadings three series of tests were conducted by the author. Firstly, the analysis of the tests showed that especially cyclic alternating loading reduces the bearing capacity of reinforced concrete beams and their crack resistance by 20 % due to the fatigue of concrete and reinforcement. Thus the change of load sign creates serious changes of stress-strain state of reinforced concrete beam elements. Low cycle loads of constant sign effect the behavior of the constructions not so adversely. Secondly, based on the experimental data mathematical models of elements’ strength were obtained. These models allow evaluating the impact of each factor on the output parameter not only separately, but also in interaction with each other. Furthermore, the material spotlighted by the author describes stress-strain state of the investigated elements, cracking mechanism, changes of deflection values, the influence of mode cyclic loading during the tests. Since the data on the subject are useful and important to building practice, the ultimate aim of the tests will be working out for improvement of nonlinear calculation models of span reinforced concrete constructions taking into account the impact of these loads, and also there will be the development of engineering calculation techniques of their strength, crack resistance and deformability.

  3. Antiretroviral treatment adherence as a mediating factor between psychosocial variables and HIV viral load.

    Science.gov (United States)

    Attonito, Jennifer; Dévieux, Jessy G; Lerner, Brenda D G; Hospital, Michelle M; Rosenberg, Rhonda

    2014-01-01

    Psychosocial factors may directly impact HIV health measures such as viral load (VL) whether or not patients are taking antiretroviral treatment (ART) consistently. Structural equation modeling plus Baron and Kenny's (1986) four-step approach were used to test a mediated model predicting VL among 246 HIV-infected adults who were on ART. Exogenous variables were social support, barriers to adherence, and stress. Moderators were alcohol use, marijuana use, and neurocognitive impairment. A small positive association between marijuana use and ART adherence approached significance. Only barriers to adherence predicted a decrease in adherence rates and an increase in VL. No other factors were significantly associated with either VL or adherence, and no interaction effects between exogenous variables and moderators were identified. The association between barriers to adherence and VL was partially mediated by ART adherence. Findings provide modest support for a direct link between psychosocial variables and a virologic response to ART. Copyright © 2014 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.

  4. Substance and Artifact in the Higher-Order Factors of the Big Five

    Science.gov (United States)

    McCrae, Robert R.; Jang, Kerry L.; Ando, Juko; Ono, Yutaka; Yamagata, Shinji; Riemann, Rainer; Angleitner, Alois; Spinath, Frank M.

    2018-01-01

    J. M. Digman (1997) proposed that the Big Five personality traits showed a higher-order structure with 2 factors he labeled α and β. These factors have been alternatively interpreted as heritable components of personality or as artifacts of evaluative bias. Using structural equation modeling, the authors reanalyzed data from a cross-national twin study and from American cross-observer studies and analyzed new multimethod data from a German twin study. In all analyses, artifact models outperformed substance models by root-mean-square error of approximation criteria, but models combining both artifact and substance were slightly better. These findings suggest that the search for the biological basis of personality traits may be more profitably focused on the 5 factors themselves and their specific facets, especially in monomethod studies. PMID:18665712

  5. Calculation of equivalent static loads and its application

    International Nuclear Information System (INIS)

    Choi, Woo-Seok; Park, K.B.; Park, G.J.

    2005-01-01

    All the forces in the real world act dynamically on structures. Since dynamic loads are extremely difficult to handle in analysis and design, static loads are usually utilized with dynamic factors. Generally, the dynamic factors are determined from design codes or experience. Therefore, static loads may not give accurate solutions in analysis and design and structural engineers often come up with unreliable solutions. Two different methods are proposed for the transformation of dynamic loads into equivalent static loads (ESLs). One is an analytical method for exact ESLs and the other is an approximation method. The exact ESLs are calculated to generate identical response fields such as displacement and stress with those from dynamic loads at a certain time. Some approximation methods are proposed in engineering applications, which generate similar response fields from dynamic loads. They are divided into the displacement-based approach and the stress-based approach. The process is derived and evaluated mathematically. Standard examples are selected and solved by the proposed method and error analyses are conducted. Applications of the method to structural optimization are discussed

  6. Wind loads on flat plate photovoltaic array fields (nonsteady winds)

    Science.gov (United States)

    Miller, R. D.; Zimmerman, D. K.

    1981-01-01

    Techniques to predict the dynamic response and the structural dynamic loads of flat plate photovoltaic arrays due to wind turbulence were analyzed. Guidelines for use in predicting the turbulent portion of the wind loading on future similar arrays are presented. The dynamic response and the loads dynamic magnification factor of the two array configurations are similar. The magnification factors at a mid chord and outer chord location on the array illustrated and at four points on the chord are shown. The wind tunnel test experimental rms pressure coefficient on which magnification factors are based is shown. It is found that the largest response and dynamic magnification factor occur at a mid chord location on an array and near the trailing edge. A technique employing these magnification factors and the wind tunnel test rms fluctuating pressure coefficients to calculate design pressure loads due to wind turbulence is presented.

  7. Short-term load forecasting of power system

    Science.gov (United States)

    Xu, Xiaobin

    2017-05-01

    In order to ensure the scientific nature of optimization about power system, it is necessary to improve the load forecasting accuracy. Power system load forecasting is based on accurate statistical data and survey data, starting from the history and current situation of electricity consumption, with a scientific method to predict the future development trend of power load and change the law of science. Short-term load forecasting is the basis of power system operation and analysis, which is of great significance to unit combination, economic dispatch and safety check. Therefore, the load forecasting of the power system is explained in detail in this paper. First, we use the data from 2012 to 2014 to establish the partial least squares model to regression analysis the relationship between daily maximum load, daily minimum load, daily average load and each meteorological factor, and select the highest peak by observing the regression coefficient histogram Day maximum temperature, daily minimum temperature and daily average temperature as the meteorological factors to improve the accuracy of load forecasting indicators. Secondly, in the case of uncertain climate impact, we use the time series model to predict the load data for 2015, respectively, the 2009-2014 load data were sorted out, through the previous six years of the data to forecast the data for this time in 2015. The criterion for the accuracy of the prediction is the average of the standard deviations for the prediction results and average load for the previous six years. Finally, considering the climate effect, we use the BP neural network model to predict the data in 2015, and optimize the forecast results on the basis of the time series model.

  8. Strength of Glued-in Bolts after Full Scale Loading

    DEFF Research Database (Denmark)

    Pedersen, Martin Bo Uhre; Clorius, Christian Odin; Damkilde, Lars

    1999-01-01

    with a length of 500 mm had a special hollow tapering giving them a higher load bearing capacity than solid bolts of equal dimensions. A FEM-analysis confirms the higher load bearing capacity. The mean residual strength was found to be 362 kN with a standard deviation of 37 kN, which is 95% of the predicted...

  9. Self-sensing piezoresistive cement composite loaded with carbon black particles

    KAUST Repository

    Monteiro, André O.

    2017-04-27

    Strain sensors can be embedded in civil engineering infrastructures to perform real-time service life monitoring. Here, the sensing capability of piezoresistive cement-based composites loaded with carbon black (CB) particles is investigated. Several composite mixtures, with a CB filler loading up to 10% of binder mass, were mechanically tested under cyclic uniaxial compression, registering variations in electrical resistance as a function of deformation. The results show a reversible piezoresistive behaviour and a quasi-linear relation between the fractional change in resistivity and the compressive strain, in particular for those compositions with higher amount of CB. Gage factors of 30 and 24 were found for compositions containing 7 and 10% of binder mass, respectively. These findings suggest that the CB-cement composites may be a promising active material to monitor compressive strain in civil infrastructures such as concrete bridges and roadways.

  10. Optimization of Nanowire-Resistance Load Logic Inverter.

    Science.gov (United States)

    Hashim, Yasir; Sidek, Othman

    2015-09-01

    This study is the first to demonstrate characteristics optimization of nanowire resistance load inverter. Noise margins and inflection voltage of transfer characteristics are used as limiting factors in this optimization. Results indicate that optimization depends on resistance value. Increasing of load resistor tends to increasing in noise margins until saturation point, increasing load resistor after this point will not improve noise margins significantly.

  11. The osteoporotic vertebral structure is well adapted to the loads of daily life, but not to infrequent "error" loads.

    Science.gov (United States)

    Homminga, J; Van-Rietbergen, B; Lochmüller, E M; Weinans, H; Eckstein, F; Huiskes, R

    2004-03-01

    Osteoporotic vertebral fractures typically have a gradual onset, frequently remain clinically undetected, and do not seem to be related to traumatic events. The osteoporotic vertebrae may therefore be expected to display a less "optimal" bone architecture, leading to an uneven load distribution over the bone material. We evaluated the trabecular load distribution in an osteoporotic and a healthy vertebra under normal daily loading by combining three recent innovations: high resolution computed tomography (microCT) of entire bones, microfinite element analyses (microFEA), and parallel supercomputers. Much to our surprise, the number of highly loaded trabeculae was not higher in the osteoporotic vertebra than in the healthy one under normal daily loads (8% and 9%, respectively). The osteoporotic trabeculae were more oriented in the longitudinal direction, compensating for effects of bone loss and ensuring adequate stiffness for normal daily loading. The increased orientation did, however, make the osteoporotic structure less resistant against collateral "error" loads. In this case, the number of overloaded trabeculae in the osteoporotic vertebra was higher than in the healthy one (13% and 4%, respectively). These results strengthen the paradigm of a strong relationship between bone morphology and external loads applied during normal daily life. They also indicate that vertebral fractures result from actions like forward flexion or lifting, loads that may not be "daily" but are normally not traumatic either. If future clinical imaging techniques would enable such high-resolution images to be obtained in vivo, the combination of microCT and microFEA would produce a powerful tool to diagnose osteoporosis.

  12. Parasite load and risk factors for poor outcome among children with visceral leishmaniasis. A cohort study in Belo Horizonte, Brazil, 2010-2011

    Directory of Open Access Journals (Sweden)

    Maria Vitória Assumpção Mourão

    2014-04-01

    Full Text Available Clinical and laboratory risk factors for death from visceral leishmaniasis (VL are relatively known, but quantitative real-time polymerase chain reaction (qPCR might assess the role of parasite load in determining clinical outcome. The aim of this study was to identify risk factors, including parasite load in peripheral blood, for VL poor outcome among children. This prospective cohort study evaluated children aged ≤ 12 years old with VL diagnosis at three times: pre-treatment (T0, during treatment (T1 and post-treatment (T2. Forty-eight patients were included and 16 (33.3% met the criteria for poor outcome. Age ≤ 12 months [relative risk (RR 3.51; 95% confidence interval (CI 1.89-6.52], tachydyspnoea (RR 3.46; 95% CI 2.19-5.47, bacterial infection (RR 3.08; 95% CI 1.27-7.48, liver enlargement (RR 3.00; 95% CI 1.44-6.23 and low serum albumin (RR 7.00; 95% CI 1.80-27.24 were identified as risk factors. qPCR was positive in all patients at T0 and the parasite DNA was undetectable in 76.1% of them at T1 and in 90.7% at T2. There was no statistical association between parasite load at T0 and poor outcome.

  13. Exclusion Factors in Latin American Higher Education: A Preliminary Analyze From University Governing Board Perspective

    Science.gov (United States)

    Castro, Diego; Rodríguez-Gómez, David; Gairín, Joaquín

    2017-01-01

    Access to higher education has increased substantially in Latin America, but inequalities in access to and completion of higher education still remain. In this regard, identifying vulnerable groups and exclusion factors is a priority in Latin America's university systems. The aim of this article is to understand in depth governing board…

  14. Heat load of a P-doped GaAs photocathode in SRF electron gun

    International Nuclear Information System (INIS)

    Wang, E.; Ben-Zvi, I.; Kewisch, J.; Burrill, A.; Rao, T.; Wu, Q.; Jain, A.; Gupta, R.; Holmes, D.

    2010-01-01

    Many efforts were made over the last decades to develop a better polarized electron source for the high energy physics. Several laboratories operate DC guns with the Gallium-Arsenide photo-cathode, which yield a highly polarized electron beam. However, the beam's emittance might well be improved using a Superconducting RF electron gun, which delivers beams of higher brightness than DC guns does, because the field gradient at the cathode is higher. SRF guns with metal cathodes and CsTe cathodes have been tested successfully. To produce polarized electrons, a Gallium-Arsenide photo-cathode must be used: an experiment to do so in a superconducting RF gun is under way at BNL. Since the cathode will be normal conducting, the problem about the heat load stemming from the cathode arises. We present our measurements of the electrical resistance of GaAs at cryogenic temperatures, a prediction of the heat load and the verification by measuring the quality factor of the gun with and without cathode.

  15. Measurement of electrodynamics characteristics of higher order modes for harmonic cavity at 2400 MHz

    Science.gov (United States)

    Shashkov, Ya V.; Sobenin, N. P.; Gusarova, M. A.; Lalayan, M. V.; Bazyl, D. S.; Donetskiy, R. V.; Orlov, A. I.; Zobov, M. M.; Zavadtsev, A. A.

    2016-09-01

    In the frameworks of the High Luminosity Large Hadron Collider (HL-LHC) upgrade program an application of additional superconducting harmonic cavities operating at 800 MHz is currently under discussion. As a possible candidate, an assembly of two cavities with grooved beam pipes connected by a drift tube and housed in a common cryomodule, was proposed. In this article we discuss measurements of loaded Q-factors of higher order modes (HOM) performed on a scaled aluminium single cell cavity prototype with the fundamental frequency of 2400 MHz and on an array of two such cavities connected by a narrow beam pipe. The measurements were performed for the system with and without the matching load in the drift tube..

  16. Associations between Dietary Acid-Base Load and Cardiometabolic Risk Factors in Adults: The Tehran Lipid and Glucose Study

    Directory of Open Access Journals (Sweden)

    Zahra Bahadoran

    2015-06-01

    Full Text Available BackgroundIn this study we investigated the associations of dietary acid-base load, identified by potential renal acid load (PRAL and protein to potassium (Pro:K ratio, with cardiometabolic risk factors in Tehranian adults.MethodsA cross-sectional study was conducted within the framework of the fourth phase of the Tehran Lipid and Glucose Study (2009 to 2011 on 5,620 men and women aged 19 to 70 years. Dietary data were collected by a trained dietitian using a validated, 147-food item, semi-quantitative food frequency questionnaire, and dietary PRAL and Pro:K ratio were calculated. Multiple linear regression models with adjustment for potential confounding variables were used to evaluate the associations of dietary acid-base load with anthropometric measures, blood pressure, serum triglycerides, high density lipoprotein cholesterol (HDL-C, serum creatinine, and fasting blood glucose.ResultsThe mean±SD age of the participants was 39.8±12.8 years and 54% of participants were women. Mean±SD PRAL was -22.0±29.1; mean PRAL was -15.6 in men and -26.8 in women. Dietary PRAL was associated with weight (β=0.098, P<0.001, waist circumference (β=0.062, P<0.01, serum triglycerides (β=0.143, P<0.01, HDL-C (β=-0.11, P<0.01, diastolic blood pressure (β=0.062, P<0.01, and serum creatinine (β=0.142, P<0.001. Pro:K ratio was associated with weight (β=0.055, P<0.001, waist circumference (β=0.04, P<0.01, serum HDL-C (β=-0.06, P<0.01, serum triglycerides (β=0.03, P<0.05, diastolic blood pressure (β=0.026, P<0.05, and serum creatinine (β=0.07, P<0.01.ConclusionA more acidic dietary acid-base load may be a risk factor for the development of metabolic disorders.

  17. Loading nature of the interfacial cracks in a joint component under fusion-relevant thermal loads

    International Nuclear Information System (INIS)

    You, J.H.

    1998-01-01

    One of the standard design concepts for divertor components in a fusion reactor is the bonded joint structure. Understanding the loading nature of interfacial cracks are significant for the assessment of structural integrity of divertor joint components. In this paper, the thermomechanical loading nature of interfacial cracks is discussed. A bi-material joint element consisting of the CFC/TZM system is considered. A typical fusion operation condition is simulated assuming a pulsed high heat flux loading. Stress singularities near the interfacial crack tips are characterized quantitatively in terms of the fracture mechanical parameters. The evolution of the stress intensity factors and the energy release rate during the given transient thermal load are determined. The difference in loading characteristics between the edge crack and the center crack is discussed. High heat flux cycling tests are performed on brazed CFC/TZM divertor elements in an electron beam test facility. The microstructures of the damaged interface agree with the predicted fracture modes. The loading nature and possible failure mechanisms are discussed for a fusion-relevant thermal loading. (orig.)

  18. Orthogonal Higher Order Structure of the WISC-IV Spanish Using Hierarchical Exploratory Factor Analytic Procedures

    Science.gov (United States)

    McGill, Ryan J.; Canivez, Gary L.

    2016-01-01

    As recommended by Carroll, the present study examined the factor structure of the Wechsler Intelligence Scale for Children-Fourth Edition Spanish (WISC-IV Spanish) normative sample using higher order exploratory factor analytic techniques not included in the WISC-IV Spanish Technical Manual. Results indicated that the WISC-IV Spanish subtests were…

  19. Demand characteristics and load factor in a sugar cane brandy distillery; Caracteristica de demanda e fator de carga numa destilaria de aguardente

    Energy Technology Data Exchange (ETDEWEB)

    Assumpcao, C R [UNESP, Ilha Solteira, SP (Brazil). Faculdade de Engenharia; Souza, L L.G. [UNESP, Botucatu, SP (Brazil). Faculdade de Ciencias Agronomicas

    1987-12-31

    The actual and calculated load factor values were also confronted for both harvests studied, looking for a polynomial equation that could represent the relationships among the variables. (author) 11 refs., 4 figs., 3 tabs.

  20. Performance of a cognitive load inventory during simulated handoffs: Evidence for validity.

    Science.gov (United States)

    Young, John Q; Boscardin, Christy K; van Dijk, Savannah M; Abdullah, Ruqayyah; Irby, David M; Sewell, Justin L; Ten Cate, Olle; O'Sullivan, Patricia S

    2016-01-01

    Advancing patient safety during handoffs remains a public health priority. The application of cognitive load theory offers promise, but is currently limited by the inability to measure cognitive load types. To develop and collect validity evidence for a revised self-report inventory that measures cognitive load types during a handoff. Based on prior published work, input from experts in cognitive load theory and handoffs, and a think-aloud exercise with residents, a revised Cognitive Load Inventory for Handoffs was developed. The Cognitive Load Inventory for Handoffs has items for intrinsic, extraneous, and germane load. Students who were second- and sixth-year students recruited from a Dutch medical school participated in four simulated handoffs (two simple and two complex cases). At the end of each handoff, study participants completed the Cognitive Load Inventory for Handoffs, Paas' Cognitive Load Scale, and one global rating item for intrinsic load, extraneous load, and germane load, respectively. Factor and correlational analyses were performed to collect evidence for validity. Confirmatory factor analysis yielded a single factor that combined intrinsic and germane loads. The extraneous load items performed poorly and were removed from the model. The score from the combined intrinsic and germane load items associated, as predicted by cognitive load theory, with a commonly used measure of overall cognitive load (Pearson's r = 0.83, p load during handoffs may be measured via a self-report measure. Additional work is required to develop an adequate measure of extraneous load.

  1. Degradation of isobutanal at high loading rates in a compost biofilter.

    Science.gov (United States)

    Sercu, Bram; Demeestere, Kristof; Baillieul, Hans; Van Langenhove, Herman; Verstraete, Willy

    2005-08-01

    Biofiltration has been increasingly used for cleaning waste gases, mostly containing low concentrations of odorous compounds. To expand the application area of this technology, the biofiltration of higher pollutant loading rates has to be investigated. This article focuses on the biodegradation of isobutanal (IBAL) in a compost biofilter (BF) at mass loading rates between 211 and 4123 g/m3/day (30-590 ppm(v)). At mass loading rates up to 785 g/m3/day, near 100% removal efficiencies could be obtained. However, after increasing the loading rate to 1500-1900 g/m3/ day, the degradation efficiency decreased to 62-98%. In addition, a pH decrease and production of isobutanol (IBOL) and isobutyric acid (IBAC) were observed. This is the first report showing that an aldehyde can act as electron donor as well as acceptor in a BF. To study the effects of pH, compost moisture content, and electron acceptor availability on the biofiltration of IBAL, IBOL, and IBAC, additional batch and continuous experiments were performed. A pH of 5.2 reduced the IBAL degradation rate and inhibited the IBOL degradation, although adaptation of the microorganisms to low pH was observed in the BFs. IBAC was not degraded in the batch experiments. High moisture content (51%) initially had no effect on the IBOL production, although it negatively affected the IBAL elimination increasingly during a 21-day time-course experiment. In batch experiments, the reduction of IBAL to IBOL did not decrease when the amount of available electron acceptors (oxygen or nitrate) was increased. The IBAL removal efficiency at higher loading rates was limited by a combination of nutrient limitation, pH decrease, and dehydration, and the importance of each limiting factor depended on the influent concentration.

  2. Factors influencing storm-generated suspended-sediment concentrations and loads in four basins of contrasting land use, humid-tropical Puerto Rico

    Science.gov (United States)

    A. C. Gellis; NO-VALUE

    2013-01-01

    The significant characteristics controlling the variability in storm-generated suspended-sediment loads and concentrations were analyzed for four basins of differing land use (forest, pasture, cropland, and urbanizing) in humid-tropical Puerto Rico. Statistical analysis involved stepwise regression on factor scores. The explanatory variables were attributes of flow,...

  3. Working memory load modulates microsaccadic rate.

    Science.gov (United States)

    Dalmaso, Mario; Castelli, Luigi; Scatturin, Pietro; Galfano, Giovanni

    2017-03-01

    Microsaccades are tiny eye movements that individuals perform unconsciously during fixation. Despite that the nature and the functions of microsaccades are still lively debated, recent evidence has shown an association between these micro eye movements and higher order cognitive processes. Here, in two experiments, we specifically focused on working memory and addressed whether differential memory load could be reflected in a modulation of microsaccade dynamics. In Experiment 1, participants memorized a numerical sequence composed of either two (low-load condition) or five digits (high-load condition), appearing at fixation. The results showed a reduction in the microsaccadic rate in the high-load compared to the low-load condition. In Experiment 2, five red or green digits were always presented at fixation. Participants either memorized the color (low-load condition) or the five digits (high-load condition). Hence, visual stimuli were exactly the same in both conditions. Consistent with Experiment 1, microsaccadic rate was lower in the high-load than in the low-load condition. Overall, these findings reveal that an engagement of working memory can have an impact on microsaccadic rate, consistent with the view that microsaccade generation is pervious to top-down processes.

  4. Incorporating moving dynamic tyre loads in pavement design and analysis

    CSIR Research Space (South Africa)

    Steyn, WJvdM

    2000-07-01

    Full Text Available at the University of Pretoria. 4 REAL LIFE TYRE LOADS Characterisation Pavement loading has been shown by various authors to be a dynamic (time-dependent) phenomenon (Divine, 1997; Cebon, 1999). A pavement experiences a vehicle as a moving, time-varying set... frequencies. Body bounce generally dominates the dynamic loading, and is mainly caused by the response of the sprung mass of the vehicle to the pavement roughness. Axle hop becomes more significant at higher vehicle speeds and higher pavement roughnesses...

  5. Higher serum levels of rheumatoid factor and anti-nuclear antibodies in helicobacter pylori-infected peptic ulcer patients.

    Science.gov (United States)

    Jafarzadeh, Abdollah; Nemati, Maryam; Rezayati, Mohammad Taghi; Nabizadeh, Mansooreh; Ebrahimi, Medhi

    2013-07-01

    H. pylori infection has been associated with some autoimmune disorders. The aim of this study was to evaluate the serum concentrations of rheumatoid factor and anti-nuclear antibodies in H. pylori-infected peptic ulcer patients, H. pylori-infected asymptomatic carriers and a healthy control group. A Total of 100 H. pylori-infected peptic ulcer patients, 65 asymptomatic carriers and 30 healthy H. pylori-negative subjects (as a control group) were enrolled into study. Serum samples of participants tested for the levels of rheumatoid factor and anti-nuclear antibodies by use of ELISA. The mean serum levels of rheumatoid factor and anti-nuclear antibodies in peptic ulcer group was significantly higher in comparison to the control group (ppeptic ulcer patients and asymptomatic carriers groups regarding the mean serum levels of rheumatoid factor and anti-nuclear antibodies. The mean serum levels of rheumatoid factor in men with peptic ulcer was significantly higher compared to the group of healthy men (ppeptic ulcer patients or asymptomatic carriers groups, the mean serum levels of rheumatoid factor was higher than that in healthy women, but the differences were not statistically significant. Also, no significant differences were observed between men and women with peptic ulcer, asymptomatic carriers control groups based on the serum levels of anti-nuclear antibodies. The results showed higher serum levels of rheumatoid factor and anti-nuclear antibodies in H. pylori-infected patients with peptic ulcer disease which represent the H. pylori-related immune disturbance in these patients. Additional follow-up studies are necessary to clarify the clinical significance of these autoantibodies in patients with H. pylori infection.

  6. Building and environmental factors that influence bacterial and fungal loading on air conditioning cooling coils.

    Science.gov (United States)

    Bakker, A; Siegel, J A; Mendell, M J; Peccia, J

    2018-05-30

    We investigated bacterial and fungal concentrations on cooling coils of commercial AC units and quantified associations between microbial loads and AC unit or building operational parameters. A field campaign was conducted to sample 25 AC units in the humid, subtropical climate of Southern CT, USA and 15 AC units in the hot-summer Mediterranean climate of Sacramento, CA, USA. Median concentrations (with interquartile range) of bacteria and fungi on the cooling coils were 1.2 × 10 7 (5.1 × 10 6 -3.9 × 10 7 ) cells/m 2 and 7.6 × 10 5 (5.6 × 10 4 -4.4 × 10 6 ) spore equivalents (SE)/m 2 , respectively. Concentrations varied among units with median unit concentrations ranging three orders of magnitude for bacteria and seven orders of magnitude for fungi. Controlled comparisons and multivariable regressions indicate that dominant factors associated with AC coil loading include the nominal efficiency of upstream filters (P = .008 for bacteria and P < .001 for fungi) and coil moisture, which was reflected in fungal loading differences between top and bottom halves of the AC coils in Southern CT (P = .05) and the dew points of the two climates considered (P = .04). Environmental and building characteristics explained 42% (P < .001) of bacterial concentration variability and 66% (P < .001) of fungal concentration variability among samples. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Tolerance Limit for Trucks with Excess Load in Transport Regulation in Indonesia

    Directory of Open Access Journals (Sweden)

    Sigit Hadiwardoyo

    2012-05-01

    Full Text Available Reliability of a road is mandatory since damaged will impede the traffic. Destruction is caused by various factors; one of the most important factors is excess load. Overload may give the load of each axle of a vehicle exceeds the determined standard. This condition occurs in trucks exceeding the load limit. In designing the structure of a road based on the method of Directorate General of Highways Ministry of Public Works of the Republic of Indonesia, axle load calculated in equivalent-number, or known as equivalent axle load (EAL, of 8.16 tons of standard axle. Total equivalent-number over the service life is defined as cumulative equivalent standard axle load (CESA. Due to traffic volume exceeding the volume forecast or, in other words there is an excessive load of traffic, it will make CESA achieved faster than planned. This excessive load in Indonesia, however, has been  considered as a factor of environmental condition, so there is a need to introduce a correction factor for EAL as high as 20-25% in the process of designing flexible and rigid pavement so as to reduce early damage.

  8. Risk factors for osteoarthritis of the hip

    Directory of Open Access Journals (Sweden)

    Filipović Karmela

    2013-01-01

    Full Text Available INTRODUCTION: Osteoarthritis of the hip is a degenerative disease of hip unknown origin, with pain, stiffness and diminished joint function. AIM: determine the influence of the load of the hip joint during professional activity and BMI as risk factors for the hip osteoarthritis. MATERIAL AND METHOD: We analysed 148 patients. Patients were divided into two groups ( I group with osteoarthritis of the hip, II group without osteoarthritis of the hip. In all, performed diagnostic procedure: anamnesis, physical examination (estimate of walking and hip joint movement, laboratory blood test and urine test radiological examination and taking data on the height and weight to calculated BMI. We assessed the data that is related to the load of the hip joint during professional activities (mostly sitting work and mostly standing job with carrying load. Statistical analysis was done using the software package SPSS 14.0, Microsoft Office Word 2003. RESULTS: In the first group, average age was 67.76 years, with females prevailing (67.6%. In this group the larger body mass was noted (81.82 ± 12.18, with statistically significant difference (T-test 2.923, p<0.01; the average BMI was higher the average BMI was higher (30.18 ± 4.6, with statistically significant difference (T-test 3.832, p<0.01. This group had more overweight patients (87.7%,with statistically significant difference (Fisher test, p<0.01. In I group 62,2% of patients were doing hard physical work (standing job with repeated carrying load and we found statistically significant difference between groups (Fisher test p<0,01. CONCLUSION: Patients with osteoarthritis of the hip had a higher body weight, higher BMI. Also we found the influence of hard physical labor at work, and they were performed mostly standing job with carrying load.

  9. The impact of selected environmental, behavioral and psychosocial factors on schoolchildren's somatic and mental health.

    Science.gov (United States)

    Vondrova, Diana; Kapsdorfer, Daniela; Argalasova, Lubica; Hirosova, Katarina; Samohyl, Martin; Sevcikova, Ludmila

    2017-03-01

    Children develop rapidly and many exogenous determinants of health significantly affect their somatic and mental development. There is a subjective perception of cognitive load associated with the educational process. The aim of the study is to assess individual environmental, behavioral and psychosocial factors influencing physical health and to investigate the amount of mental load in children. We investigated 87 schoolchildren (47 girls and 40 boys) aged 10-12 years, who were attending primary school in Bratislava. To assess values of selected factors we used a questionnaire form and personality characteristics were estimated by standardized psycho-diagnostic and IQ tests [range of classic fear, social-situation anxiety and jitters [skala Klasickeho strachu a Socialno-situacnej (in Slovak)] (KSAT), Eyesenck Personality Questionnaire for children (EPQ), Raven's IQ test]. Self-reported perception of mental load was assessed by questionnaire of subjective feelings and states (SFS). Children's body parameters were assessed using anthropometric measurements [height, weight, chest, abdominal and hip girth, Rohrer's index (RI), body mass index (BMI)] and a body fat measurement method (skinfold thickness). The results confirmed a significant relationship between higher parameters of overweight and obesity and irregular breakfast eating (pmental effort and cognitive load associated with the educational process. We note a close relationship between the higher mental load and the score of neuroticism (pmental health of schoolchildren is significantly affected by exogenous factors. Therefore, in terms of protection and promotion of children's health, it is important to evaluate and monitor environmental risk factors and to form their healthy habits.

  10. Loads and loads and loads: the influence of prospective load, retrospective load, and ongoing task load in prospective memory

    Science.gov (United States)

    Meier, Beat; Zimmermann, Thomas D.

    2015-01-01

    In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load (OTL) can affect prospective memory performance. The existence of multiple target events increases prospective load (PL) and adding complexity to the to-be-remembered action increases retrospective load (RL). In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of PL on costs in the ongoing task for categorical targets (Experiment 2), but not for specific targets (Experiment 1). RL and OTL both affected remembering the retrospective component of the prospective memory task. We suggest that PL can enhance costs in the ongoing task due to additional monitoring requirements. RL and OTL seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially. PMID:26082709

  11. Loads and loads and loads: the influence of prospective load, retrospective load, and ongoing task load in prospective memory.

    Science.gov (United States)

    Meier, Beat; Zimmermann, Thomas D

    2015-01-01

    In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load (OTL) can affect prospective memory performance. The existence of multiple target events increases prospective load (PL) and adding complexity to the to-be-remembered action increases retrospective load (RL). In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of PL on costs in the ongoing task for categorical targets (Experiment 2), but not for specific targets (Experiment 1). RL and OTL both affected remembering the retrospective component of the prospective memory task. We suggest that PL can enhance costs in the ongoing task due to additional monitoring requirements. RL and OTL seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially.

  12. High Temperature Radio Frequency Loads

    CERN Document Server

    Federmann, S; Grudiev, A; Montesinos, E; Syratchev, I

    2011-01-01

    In the context of energy saving and recovery requirements the design of reliable and robust RF power loads which permit a high outlet temperature and high pressure of the cooling water is desirable. Cooling water arriving at the outlet withmore than 150 ◦C and high pressure has a higher value than water with 50 ◦C under low pressure. Conventional RF power loads containing dielectric and magnetic materials as well as sensitive ceramic windows usually do not permit going much higher than 90 ◦C. Here we present and discuss several design concepts for "metal only" RF high power loads. One concept is the application of magnetic steel corrugated waveguides near cutoff – this concept could find practical use above several GHz. Another solution are resonant structures made of steel to be installed in large waveguides for frequencies of 500 MHz or lower. Similar resonant structures above 100 MHz taking advantage of the rather high losses of normal steel may also be used in coaxial line geometries with large di...

  13. Clinical Factors and Viral Load Influencing Severity of Acute Hepatitis A.

    Science.gov (United States)

    Lee, Hyun Woong; Chang, Dong-Yeop; Moon, Hong Ju; Chang, Hye Young; Shin, Eui-Cheol; Lee, June Sung; Kim, Kyung-Ah; Kim, Hyung Joon

    2015-01-01

    Clinical manifestations of hepatitis A virus (HAV) infection vary from mild to fulminant hepatic failure (FHF) in adults. We investigated the relationship between laboratory findings, including viral load, and clinical outcomes in patients with acute hepatitis A (AHA) and evaluated predictive factors for severe acute hepatitis (s-AH). We analyzed the clinical manifestations of AHA in 770 patients. Patients with a prothrombin time (PT) of less than 40% of normal were classified as s-AH and included 4 patients with FHF, 11 patients with acute renal failure, and 3 patients with prolonged jaundice (n = 128). Other patients were defined as mild acute hepatitis (m-AH) (n = 642). Serum samples were obtained from 48 patients with acute hepatitis A. Among them, 20 with s-AH, and 28 with m-AH, were tested for HAV RNA titer. In a multivariate analysis, age (HR = 1.042, P = 0.041), peak creatinine (HR = 4.014, P = 0.001), bilirubin (HR = 1.153, P = 0.003), alanine aminotransferase (ALT) (HR = 1.001, P hepatitis A.

  14. Clinical Factors and Viral Load Influencing Severity of Acute Hepatitis A

    Science.gov (United States)

    Lee, Hyun Woong; Chang, Dong-Yeop; Moon, Hong Ju; Chang, Hye Young; Shin, Eui-Cheol; Lee, June Sung; Kim, Kyung-Ah; Kim, Hyung Joon

    2015-01-01

    Background and Aims Clinical manifestations of hepatitis A virus (HAV) infection vary from mild to fulminant hepatic failure (FHF) in adults. We investigated the relationship between laboratory findings, including viral load, and clinical outcomes in patients with acute hepatitis A (AHA) and evaluated predictive factors for severe acute hepatitis (s-AH). Methods We analyzed the clinical manifestations of AHA in 770 patients. Patients with a prothrombin time (PT) of less than 40% of normal were classified as s-AH and included 4 patients with FHF, 11 patients with acute renal failure, and 3 patients with prolonged jaundice (n = 128). Other patients were defined as mild acute hepatitis (m-AH) (n = 642). Serum samples were obtained from 48 patients with acute hepatitis A. Among them, 20 with s-AH, and 28 with m-AH, were tested for HAV RNA titer. Results In a multivariate analysis, age (HR = 1.042, P = 0.041), peak creatinine (HR = 4.014, P = 0.001), bilirubin (HR = 1.153, P = 0.003), alanine aminotransferase (ALT) (HR = 1.001, Phepatitis A. PMID:26090677

  15. Investigation of the factor structure of the Wechsler Adult Intelligence Scale--Fourth Edition (WAIS-IV): exploratory and higher order factor analyses.

    Science.gov (United States)

    Canivez, Gary L; Watkins, Marley W

    2010-12-01

    The present study examined the factor structure of the Wechsler Adult Intelligence Scale--Fourth Edition (WAIS-IV; D. Wechsler, 2008a) standardization sample using exploratory factor analysis, multiple factor extraction criteria, and higher order exploratory factor analysis (J. Schmid & J. M. Leiman, 1957) not included in the WAIS-IV Technical and Interpretation Manual (D. Wechsler, 2008b). Results indicated that the WAIS-IV subtests were properly associated with the theoretically proposed first-order factors, but all but one factor-extraction criterion recommended extraction of one or two factors. Hierarchical exploratory analyses with the Schmid and Leiman procedure found that the second-order g factor accounted for large portions of total and common variance, whereas the four first-order factors accounted for small portions of total and common variance. It was concluded that the WAIS-IV provides strong measurement of general intelligence, and clinical interpretation should be primarily at that level.

  16. Determinación IN-SITU del factor de potencia y la eficiencia de motores asincrónicos a cargas parciales; Induction motor power factor and efficiency IN-SITU determination under partial loads.

    Directory of Open Access Journals (Sweden)

    Percy Rafael Viego Felipe

    2015-04-01

    Full Text Available Los motores asincrónicos trifásicos no siempre operan a plena carga y por lo tanto, el factor de potencia y la eficiencia se ven afectados. Determinar estos valores a diferentes cargas, es la base para programas ahorro en la industria y los servicios. En este trabajo se presentan procedimientos para la estimación del factor de potencia y la eficiencia a cargas parciales, con una precisión acorde a los propósitos ingenieriles, baja invasividad y sin implicar para el usuario complejidades de equipamiento o de adquisición y procesamiento de datos. Se ofrecen distintas variantes para la estimación del factor de potencia y la eficiencia, según los datos con que se cuente. Se comparan los resultados de los métodos propuestos con la información de catálogos comerciales. Se realiza un análisis con motores de distinta potencia y velocidad, que demuestra que se logra buena precisión para los propósitos señalados. Three phase induction motors are rarely operating at full load and, in consequence, power factor and efficiency are affected. Determining these values for different partial loads is needed for energy saving programs in industrial and service enterprises. In this work, procedures are given for power factor and efficiency estimation at different loads. These procedures are low or not-invasive, have a good precision for engineering purposes, and do not require neither complex equipment nor complicated acquisition and processing data systems Different ways for estimating the before mentioned parameters, depending on the known data, are given. The results of the proposed procedures are compared with those of manufacturer catalogs. A comparative analysis considering motors of different output power and speed is done, and it shows that the results are enough accurate for the established purposes.

  17. Corporate Image of Public Higher Education Institutions: Relevant Factors to Distance Learning Students

    Science.gov (United States)

    da Costa, Fabio R.; Pelissari, Anderson S.; Gonzalez, Inayara V. D. P.

    2018-01-01

    Technological advances are generating a significant increase in the supply of distance learning (DL) courses via the Internet, increasing the importance of this type of education for the university's structure. This article identifies factors associated with perceptions of the public higher education institutions' image from the perspective of DL…

  18. Examining Success Factors Related to ERP Implementations in Higher Education Shared Services Projects

    Science.gov (United States)

    Stoyanoff, Dawn Galadriel Pfeiffer

    2012-01-01

    This study examined the enterprise resource planning (ERP) implementations that utilized a shared services model in higher education. The purpose of this research was to examine the critical success factors which were perceived to contribute to project success. This research employed a quantitative non-experimental correlational design and the…

  19. Contextual Factors Influencing Student Absenteeism at a Higher Education Institution in South Africa

    Science.gov (United States)

    Ramchander, Manduth

    2017-01-01

    Student absenteeism at higher education institutions (HEIs) is a cause for concern as it has implications for students' academic performance and therefore graduation rates. Graduation rates to some extent influence funding to which universities are entitled. This study aimed to establish the contextual factors that influenced student absenteeism…

  20. A modified electronic load based on cascode linear MOSFET configuration

    DEFF Research Database (Denmark)

    Farhang, Peyman; Mátéfi-Tempfli, Stefan

    2017-01-01

    Although switched-mode Electronic Loads (E-Loads) are commonly used in different applications, they are facing particular limitations especially for higher frequency purposes. While increasing the switching frequency in switched-mode E-Loads enables them to operate at high frequencies, simply ris...

  1. Economic impact analysis of load forecasting

    International Nuclear Information System (INIS)

    Ranaweera, D.K.; Karady, G.G.; Farmer, R.G.

    1997-01-01

    Short term load forecasting is an essential function in electric power system operations and planning. Forecasts are needed for a variety of utility activities such as generation scheduling, scheduling of fuel purchases, maintenance scheduling and security analysis. Depending on power system characteristics, significant forecasting errors can lead to either excessively conservative scheduling or very marginal scheduling. Either can induce heavy economic penalties. This paper examines the economic impact of inaccurate load forecasts. Monte Carlo simulations were used to study the effect of different load forecasting accuracy. Investigations into the effect of improving the daily peak load forecasts, effect of different seasons of the year and effect of utilization factors are presented

  2. Hood River Conservation Project load analysis

    Energy Technology Data Exchange (ETDEWEB)

    Stovall, T.K.

    1987-11-01

    As a part of the Hood River Conservation Project (HRCP), 314 homes were monitored to measure electrical energy use. The total electrical load, space heating load, water heating load (in about 200 homes), wood-stove heat output (in about 100 homes), and indoor temperature were monitored. Data were collected for one full year before and one full year after these homes were retrofit with conservation measures. Local weather information was also collected on a 15-min basis. This data base was used to evaluate the load savings attributable to HRCP. Two methods of weather normalization were used and showed close agreement. The weather-normalized diversified residential load savings on the Pacific Power and Light system and Hood River area peak days were >0.5 kW/household. The average spring, summer, and fall savings were much smaller, <0.1 kW/household. The load factor for the diversified residential load decreased following the conservation retrofit actions. 11 refs., 40 figs., 13 tabs.

  3. The second higher education and additional education as factors of development of commercialization in Ukrainian higher education

    Directory of Open Access Journals (Sweden)

    M. V. Strigul

    2017-07-01

    Full Text Available The attention in the article has been drawn to the nature and characteristics of commercialization in the higher education system of Ukraine. It has been noted that commercialization in the consumer society is a social process of transformation of knowledge into a product or service. It provides the growing influence of market relations on the goals and objectives of higher education, promotes the growing importance of knowledge as a source for economic development and focuses on the concept of rooting and academic capitalism and the creation of market-oriented and entrepreneurial universities, which provide dynamic development of economy based on knowledge. Defining the essence of the Ukrainian forms of commercialization, there is a significant role of further and second higher education (that is, the presence of a variety of educational forms, which allows the University receiving the profit in the monetary form. The model of commercialization, which is implemented in Ukrainian higher education, differs from the American and Western European ones, as it is focused on financial returns, not on the economization of intellectual profit. Secondly, a peculiar type of consumer behavior, consumerism, which provides growth of profitability of higher education institutions by a variety of additional services (training, additional courses, further education, developing classes, retaking tests, etc.. The factors of development and dynamics of the Ukrainian forms of commercialization, as well as recommendations for avoiding the negative consequences of the economization and commercialization in higher education structure of modern Ukraine have been considered in the article. It has been noted that the University lost its original purpose and became a huge supermarket, which offers various kinds of knowledge. Rational action considers in the desire to buy the most qualitative product – a diploma from a prestigious University. Nowadays, the higher

  4. Reliability analysis of RC containment structures under combined loads

    International Nuclear Information System (INIS)

    Hwang, H.; Reich, M.; Kagami, S.

    1984-01-01

    This paper discusses a reliability analysis method and load combination design criteria for reinforced concrete containment structures under combined loads. The probability based reliability analysis method is briefly described. For load combination design criteria, derivations of the load factors for accidental pressure due to a design basis accident and safe shutdown earthquake (SSE) for three target limit state probabilities are presented

  5. Factors identified with higher levels of career satisfaction of physicians in Andalusia, Spain

    Directory of Open Access Journals (Sweden)

    Juan Nicolás Peña-Sánchez

    2014-09-01

    Full Text Available The satisfaction of physicians is a world-wide issue linked with the quality of health services; their satisfaction needs to be studied from a multi-dimensional perspective, considering lower- and higher-order needs. The objectives of this study were to: i measure the career satisfaction of physicians; ii identify differences in the dimensions of career satisfaction; and iii test factors that affect higher- and lower-order needs of satisfaction among physicians working in Andalusian hospitals (Spain. Forty-one percent of 299 eligible physicians participated in a study conducted in six selected hospitals. Physicians reported higher professional, inherent, and performance satisfaction than personal satisfaction. Foreign physicians reported higher levels of personal and performance satisfaction than local physicians, and those who received non-monetary incentives had higher professional and performance satisfaction. In conclusion, physicians in the selected Andalusian hospitals reported low levels of personal satisfaction. Non-monetary incentives were more relevant to influence their career satisfaction. Further investigations are recommended to study differences in the career satisfaction between foreign and local physicians.

  6. Probabilistic representation of duration of load effects in timber structures

    DEFF Research Database (Denmark)

    Svensson, Staffan

    2011-01-01

    Reliability analysis of structures for the purpose of code calibration or reliability verification of specific structures requires that the relevant failure modes are represented and analyzed. For structural timber, sustaining a life load, two failure cases for each failure mode have......-based design of timber structures in terms of a modification factor View the MathML source which is multiplied on the short-term resistance of the timber material. The scenario of a beam subject to office space life loads is analyzed and the modification factor View the MathML source is calibrated by using...... to be considered. These two cases are maximum load level exceeding load-carrying capacity and damage accumulation (caused by the load and its duration) leading to failure. The effect of both load intensity and load duration on the capacity of timber has been an area of large interest over the last decades...

  7. Calibration of Load Duration Factor kmod

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Stang, Birgitte Friis Dela; Svensson, Staffan

    and the stochastic models are formulated in accordance with the load models in the Danish structural codes, DS 409, and DS 410. three damage accumulation models are considered, namely Gerhards model, Barret & Foschi's model, and Foschi & Yao's model. The parameters in these moels are fitted using data relevant...

  8. Fifty years of genetic load

    International Nuclear Information System (INIS)

    Wallace, B.

    1991-01-01

    This book discusses the radiation effects on Drosophila. It was originally thought that irradiating Drosophila would decrease the average fitness of the population, thereby leading to information about the detrimental effects of mutations. Surprisingly, the fitness of the irradiated population turned out to be higher than that of the control population. The original motivation for the experiment was as a test of genetic load theory. The average fitness of a population is depressed by deleterious alleles held in the population by the balance between mutation and natural selection. The depression is called the genetic load of the population. The load dose not depend on the magnitude of the deleterious effect of alleles, but only on the mutation rate

  9. Measuring child maltreatment using multi-informant survey data: a higher-order confirmatory factor analysis.

    Science.gov (United States)

    Salum, Giovanni A; DeSousa, Diogo Araújo; Manfro, Gisele Gus; Pan, Pedro Mario; Gadelha, Ary; Brietzke, Elisa; Miguel, Eurípedes Constantino; Mari, Jair J; do Rosário, Maria Conceição; Grassi-Oliveira, Rodrigo

    2016-01-01

    To investigate the validity and reliability of a multi-informant approach to measuring child maltreatment (CM) comprising seven questions assessing CM administered to children and their parents in a large community sample. Our sample comprised 2,512 children aged 6 to 12 years and their parents. Child maltreatment (CM) was assessed with three questions answered by the children and four answered by their parents, covering physical abuse, physical neglect, emotional abuse and sexual abuse. Confirmatory factor analysis was used to compare the fit indices of different models. Convergent and divergent validity were tested using parent-report and teacher-report scores on the Strengths and Difficulties Questionnaire. Discriminant validity was investigated using the Development and Well-Being Assessment to divide subjects into five diagnostic groups: typically developing controls (n = 1,880), fear disorders (n = 108), distress disorders (n = 76), attention deficit hyperactivity disorder (n = 143) and oppositional defiant disorder/conduct disorder (n = 56). A higher-order model with one higher-order factor (child maltreatment) encompassing two lower-order factors (child report and parent report) exhibited the best fit to the data and this model's reliability results were acceptable. As expected, child maltreatment was positively associated with measures of psychopathology and negatively associated with prosocial measures. All diagnostic category groups had higher levels of overall child maltreatment than typically developing children. We found evidence for the validity and reliability of this brief measure of child maltreatment using data from a large survey combining information from parents and their children.

  10. Factors for Successful Use of Social Networking Sites in Higher Education

    Directory of Open Access Journals (Sweden)

    L Schlenkrich

    2012-09-01

    Full Text Available Social networking sites are extremely popular online destinations that offer users easy ways to build and maintain relationships with each other, and to disseminate information in an activity referred to as social networking. Students, lecturers, teachers, parents and businesses, in increasing numbers, use tools available on social networking sites to communicate with each other in a fast and cost-effective manner. The use of social networking sites to support educational initiatives has received much attention. However, the full potential of social network sites has yet to be achieved as users continue to strive for optimal ways of using these sites, as well as battle to overcome the negative characteristics (for example, privacy, security, governance, user behaviour, information quality of these sites. This paper proposes factors for successful use of social networking sites in higher educational institutions. These success factors need to be adopted by users in order to develop the positive aspects of social networking, while at the same time mitigating the negative characteristics. An initial set of factors for successful use of social networking sites, as well as measures to test successful use of social networking sites were derived from the literature. These factors were tested by means of an online survey of students at a university, the results of which informed the final factors for successful use of social networking sites. The factors enable users to overcome the negative characteristics associated with social networking sites. If used successfully, social networking sites can offer lecturers and students a useful tool with which to develop their relationship and contribute to their learning experience.

  11. Maximum allowable load on wheeled mobile manipulators

    International Nuclear Information System (INIS)

    Habibnejad Korayem, M.; Ghariblu, H.

    2003-01-01

    This paper develops a computational technique for finding the maximum allowable load of mobile manipulator during a given trajectory. The maximum allowable loads which can be achieved by a mobile manipulator during a given trajectory are limited by the number of factors; probably the dynamic properties of mobile base and mounted manipulator, their actuator limitations and additional constraints applied to resolving the redundancy are the most important factors. To resolve extra D.O.F introduced by the base mobility, additional constraint functions are proposed directly in the task space of mobile manipulator. Finally, in two numerical examples involving a two-link planar manipulator mounted on a differentially driven mobile base, application of the method to determining maximum allowable load is verified. The simulation results demonstrates the maximum allowable load on a desired trajectory has not a unique value and directly depends on the additional constraint functions which applies to resolve the motion redundancy

  12. Changes in spine loading patterns throughout the workday as a function of experience, lift frequency, and personality.

    Science.gov (United States)

    Chany, Anne-Marie; Parakkat, Julia; Yang, Gang; Burr, Deborah L; Marras, William S

    2006-01-01

    Psychosocial stressors have been associated with low back pain reporting. However, response to psychosocial risk factors may be dependent on the individual's personality type that, in turn, can affect muscle recruitment and spine loading. This study explores how personality might be associated with spine loading during repetitive lifting performed throughout an entire work shift. Assess spine loading as a function of an individual's personality type during repetitive, long-term exposure to a materials handling tasks. Laboratory experiment where experienced and inexperienced participants performed repetitive, asymmetric lifts at various load and lift frequency levels throughout a series of 8-hour exposure periods. Spine loads were monitored throughout the work period. Twelve novice and 12 experienced materials handlers who were asymptomatic for back pain. Spine compression, anterior-posterior (A/P) shear, and lateral shear at the L5-S1 level. Participants were categorized into personality types based upon the Myers-Briggs personality type indicator. An electromyography-assisted biomechanical model was used to assess spine compression, A/P shear, and lateral shear throughout the exposure period. The results indicate that intuitors had higher shear spinal loading regardless of moment exposure, lift frequency, and time through the work period, compared with the sensor personality type. In addition, higher spine compressive and shear forces occurred in the perceiver personality compared with the judgers' personality trait, regardless of moment and, often, lift frequency. Novice lifters typically experienced greater spine loading. The results suggest that when there exists a personality-job environment mismatch, spinal loading increases via an increase in antagonistic co-contraction. The trends suggest that inherent personality characteristics may play a role in one's motor control strategies when performing a repetitive lifting task.

  13. The Higher Order Factor Structure and Gender Invariance of the Pathological Narcissism Inventory

    Science.gov (United States)

    Wright, Aidan G. C.; Lukowitsky, Mark R.; Pincus, Aaron L.; Conroy, David E.

    2010-01-01

    The Pathological Narcissism Inventory (PNI) is a recently developed multidimensional inventory for the assessment of pathological narcissism. The authors describe and report the results of two studies that investigate the higher order factor structure and gender invariance of the PNI. The results of the first study indicate that the PNI has a…

  14. Non-Intrusive Load Monitoring of HVAC Components using Signal Unmixing

    Energy Technology Data Exchange (ETDEWEB)

    Rahimpour, Alireza [University of Tennessee, Knoxville (UTK); Qi, Hairong [ORNL; Fugate, David L [ORNL; Kuruganti, Teja [ORNL

    2015-01-01

    Heating, Ventilating and Air Conditioning units (HVAC) are a major electrical energy consumer in buildings. Monitoring of the operation and energy consumption of HVAC would increase the awareness of building owners and maintenance service providers of the condition and quality of performance of these units, enabling conditioned-based maintenance which would help achieving higher energy efficiency. In this paper, a novel non-intrusive load monitoring method based on group constrained non-negative matrix factorization is proposed for monitoring the different components of HVAC unit by only measuring the whole building aggregated power signal. At the first level of this hierarchical approach, power consumption of the building is decomposed to energy consumption of the HVAC unit and all the other electrical devices operating in the building such as lighting and plug loads. Then, the estimated power signal of the HVAC is used for estimating the power consumption profile of the HVAC major electrical loads such as compressors, condenser fans and indoor blower. Experiments conducted on real data collected from a building testbed maintained at the Oak Ridge National Laboratory (ORNL) demonstrate high accuracy on the disaggregation task.

  15. Guideline for load and resistance assessment of existing european railway bridges

    OpenAIRE

    JENSEN, Jens S; CASAS, Joan R; KAROUMI, Raid; PLOS, Mario; CREMONA, Christian; MELBOURNE, Clive

    2008-01-01

    Many of the European railway bridges are getting close to the end of their service life. At the same time the railway operators demand higher axle loads for freight trains and higher speeds for passenger trains. This requires new and better approaches for assessing both the railway loads and the resistance of railway bridges. The main objective of the "Guideline for Load and Resistance Assessment of Existing European Railway Bridges", developed within EU founded project "Sustainable Bridge...

  16. Discrimination and anger control as pathways linking socioeconomic disadvantage to allostatic load in midlife.

    Science.gov (United States)

    Zilioli, Samuele; Imami, Ledina; Ong, Anthony D; Lumley, Mark A; Gruenewald, Tara

    2017-12-01

    Recent evidence suggests that experiences of discrimination contribute to socioeconomic status health disparities. The current study examined if the experience and regulation of anger-an expected emotional response to discrimination-serves as an explanatory factor for the previously documented links between socioeconomic disadvantage (SED), discrimination, and allostatic load. Data were drawn from the second wave of the Midlife in the United States (MIDUS) study and included 909 adults who participated in the biomarkers subproject. Results revealed that perceived discrimination was associated with higher levels of allostatic load. Furthermore, we found evidence that perceived discrimination and anger control sequentially explained the relationship between SED and allostatic load, such that greater discrimination was associated with lower levels of anger control, which, in turn accounted for the effects of discrimination on allostatic load. These results remained significant after controlling for negative affect, positive affect, other forms of anger expression, as well as demographic covariates. Our findings suggest that low anger control may be an important psychological pathway through which experiences of discrimination influence health. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Differences in Bordetella pertussis DNA load according to clinical and epidemiological characteristics of patients with whooping cough.

    Science.gov (United States)

    Brotons, Pedro; de Paz, Hector D; Toledo, Diana; Villanova, Marta; Plans, Pedro; Jordan, Iolanda; Dominguez, Angela; Jane, Mireia; Godoy, Pere; Muñoz-Almagro, Carmen

    2016-04-01

    To identify associations between nasopharyngeal Bordetella pertussis DNA load and clinical and epidemiological characteristics and evaluate DNA load prognostic value in pertussis severity. Prospective observational multi-centre study including nasopharyngeal samples positive to pertussis DNA by real-time PCR collected from children and adult patients in more than 200 health centres of Catalonia (Spain) during 2012-2013. B. pertussis load was inversely correlated with age (rho = -0.32, p < 0.001), time to diagnosis (rho = -0.33, p < 0.001) and number of symptoms (rho = 0.13, p = 0.002). Median bacterial load was significantly higher in inpatients versus outpatients (4.91 vs. 2.55 log10 CFU/mL, p < 0.001), patients with complications versus those without (6.05 vs. 2.82 log10 CFU/mL, p < 0.001), disease incidence in summer and autumn versus spring and winter (3.50 vs. 2.21 log10 CFU/mL, p = 0.002), and unvaccinated-partially vaccinated patients versus vaccinated (4.20 vs. 2.76 log10 CFU/mL, p = 0.004). A logistic regression model including bacterial load and other candidate prognostic factors showed good prediction for hospital care (AUC = 0.94) although only age and unvaccinated status were found to be prognostic factors. We observed strong positive associations of nasopharyngeal bacterial load with severity outcomes of hospitalisation and occurrence of complications. Bacterial load and other independent variables contributed to an accurate prognostic model for hospitalisation. Copyright © 2016 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  18. Effect of vibration loading on the fatigue life of part-through notched pipe

    International Nuclear Information System (INIS)

    Mittal, Rahul; Singh, P.K.; Pukazhendi, D.M.; Bhasin, V.; Vaze, K.K.; Ghosh, A.K.

    2011-01-01

    A systematic experimental and analytical study has been carried out to investigate the effect of vibration loading on the fatigue life of the piping components. Three Point bend (TPB) specimens machined from the actual pipe have been used for the evaluation of Paris constants by carrying out the experiments under vibration + cyclic and cyclic loading as per the ASTM Standard E647. These constants have been used for the prediction of the fatigue life of the pipe having part-through notch of a/t = 0.25 and aspect ratio (2c/a) of 10. Predicted results have shown the reduction in fatigue life of the notched pipe subjected to vibration + cyclic loading by 50% compared to that of cyclic loading. Predicted results have been validated by carrying out the full-scale pipe (with part-through notch) tests. Notched pipes were subjected to loading conditions such that the initial stress-intensity factor remains same as that of TPB specimen. Experimental results of the full-scale pipe tests under vibration + cyclic loading has shown the reduction in fatigue life by 70% compared to that of cyclic loading. Fractographic examination of the fracture surface of the tested specimens subjected to vibration + cyclic loading have shown higher presence of brittle phases such as martensite (in the form of isolated planar facets) and secondary micro cracks. This could be the reason for the reduction of fatigue life in pipe subjected to vibration + cyclic loading. - Highlights: → Vibration loading affects fatigue crack growth rate. → Crack initiation life depends on crack tip radius. → Crack initiation life depends on the characteristic distance. → Characteristic distance depends on the loading conditions. → Vibration + cyclic load gives lower fatigue life.

  19. Is Hand Selection Modulated by Cognitive-perceptual Load?

    Science.gov (United States)

    Liang, Jiali; Wilkinson, Krista; Sainburg, Robert L

    2018-01-15

    Previous studies proposed that selecting which hand to use for a reaching task appears to be modulated by a factor described as "task difficulty". However, what features of a task might contribute to greater or lesser "difficulty" in the context of hand selection decisions has yet to be determined. There has been evidence that biomechanical and kinematic factors such as movement smoothness and work can predict patterns of selection across the workspace, suggesting a role of predictive cost analysis in hand-selection. We hypothesize that this type of prediction for hand-selection should recruit substantial cognitive resources and thus should be influenced by cognitive-perceptual loading. We test this hypothesis by assessing the role of cognitive-perceptual loading on hand selection decisions, using a visual search task that presents different levels of difficulty (cognitive-perceptual load), as established in previous studies on overall response time and efficiency of visual search. Although the data are necessarily preliminary due to small sample size, our data suggested an influence of cognitive-perceptual load on hand selection, such that the dominant hand was selected more frequently as cognitive load increased. Interestingly, cognitive-perceptual loading also increased cross-midline reaches with both hands. Because crossing midline is more costly in terms of kinematic and kinetic factors, our findings suggest that cognitive processes are normally engaged to avoid costly actions, and that the choice not-to-cross midline requires cognitive resources. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.

  20. Fatigue failure load of two resin-bonded zirconia-reinforced lithium silicate glass-ceramics: Effect of ceramic thickness.

    Science.gov (United States)

    Monteiro, Jaiane Bandoli; Riquieri, Hilton; Prochnow, Catina; Guilardi, Luís Felipe; Pereira, Gabriel Kalil Rocha; Borges, Alexandre Luiz Souto; de Melo, Renata Marques; Valandro, Luiz Felipe

    2018-06-01

    To evaluate the effect of ceramic thickness on the fatigue failure load of two zirconia-reinforced lithium silicate (ZLS) glass-ceramics, adhesively cemented to a dentin analogue material. Disc-shaped specimens were allocated into 8 groups (n=25) considering two study factors: ZLS ceramic type (Vita Suprinity - VS; and Celtra Duo - CD), and ceramic thickness (1.0; 1.5; 2.0; and 2.5mm). A trilayer assembly (ϕ=10mm; thickness=3.5mm) was designed to mimic a bonded monolithic restoration. The ceramic discs were etched, silanized and luted (Variolink N) into a dentin analogue material. Fatigue failure load was determined using the Staircase method (100,000 cycles at 20Hz; initial fatigue load ∼60% of the mean monotonic load-to-failure; step size ∼5% of the initial fatigue load). A stainless-steel piston (ϕ=40mm) applied the load into the center of the specimens submerged in water. Fractographic analysis and Finite Element Analysis (FEA) were also performed. The ceramic thickness influenced the fatigue failure load for both ZLS materials: Suprinity (716N up to 1119N); Celtra (404N up to 1126N). FEA showed that decreasing ceramic thickness led to higher stress concentration on the cementing interface. Different ZLS glass-ceramic thicknesses influenced the fatigue failure load of the bonded system (i.e. the thicker the glass ceramic is, the higher the fatigue failure load will be). Different microstructures of the ZLS glass-ceramics might affect the fatigue behavior. FEA showed that the thicker the glass ceramic is, the lower the stress concentration at the tensile surface will be. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  1. Native American High School Seniors' Perceptions of Higher Education: Motivating and Demotivating Factors

    Science.gov (United States)

    Krogman, Calvin

    2013-01-01

    For many Native American students, particularly those from reservations, the pursuit of higher education is a formidable concept to grasp. Poverty, rural isolation, and a myriad of social ills all take a role as demotivational factors that act as barriers between Native American students and a college education. On the other hand, family,…

  2. Long-Term Survival of Dental Implants with Different Prosthetic Loading Times in Healthy Patients: A 5-Year Retrospective Clinical Study.

    Science.gov (United States)

    Muelas-Jiménez, M Isabel; Olmedo-Gaya, Maria Victoria; Manzano-Moreno, Francisco J; Reyes-Botella, Candela; Vallecillo-Capilla, Manuel

    2017-02-01

    To compare survival rates among dental implants restored with immediate, early, and conventional loading protocols, also comparing between maxillary and mandibular implants, and to evaluate the influence of implant length and diameter and the type of prosthesis on treatment outcomes. This retrospective cohort study initially included all 52 patients receiving dental implants between July 2006 and February 2008 at a private oral surgery clinic in Granada (Southern Spain). Clinical and radiographic examinations were performed, including periapical or panoramic radiographs, and incidences during completion of the restoration were recorded at 1 week, 3 months, 6 months, and at 1, 2, 3, 4, and 5 years. After a 5-year follow-up, 1 patient had died, 3 were lost to follow-up, and 6 required grafting before implant placement; therefore, the final study sample comprised 42 patients with 164 implants. Variables associated with the survival/failure of the restoration were: number of implants (higher failure rate with fewer implants), bone type (higher failure rate in type III or IV bone), and type of prosthesis (higher failure rate with single crowns). No significant association was found in univariate or multivariate analyses between survival rate and the loading protocol, implant length or diameter, or maxillary/mandibular location. Immediate occlusal loading, immediate provisionalization without occlusal loading, and early loading are viable treatment options with similar survival rates to those obtained with conventional loading. Bone quality and number of implants per patient were the most influential factors. © 2015 by the American College of Prosthodontists.

  3. Influence of crop load on almond tree water status and its importance in irrigation scheduling

    Science.gov (United States)

    Puerto Conesa, Pablo; Domingo Miguel, Rafael; Torres Sánchez, Roque; Pérez Pastor, Alejandro

    2014-05-01

    In the Mediterranean area water is the main factor limiting crop production and therefore irrigation is essential to achieve economically viable yields. One of the fundamental techniques to ensure that irrigation water is managed efficiently with maximum productivity and minimum environmental impact is irrigation scheduling. The fact that the plant water status integrates atmospheric demand and soil water content conditions encourages the use of plant-based water status indicators. Some researchers have successfully scheduled irrigation in certain fruit trees by maintaining the maximum daily trunk diameter shrinkage (MDS) signal intensity at threshold values to generate (or not) water stress. However MDS not only depends on the climate and soil water content, but may be affected by tree factors such as age, size, phenological stage and fruit load. There is therefore a need to quantify the influence of these factors on MDS. The main objective of this work was to study the effects of crop load on tree water relations for scheduling purposes. We particularly focused on MDS vs VPD10-15 (mean air vapor pressure deficit during the period 10.00-15.00 h solar time) for different loads and phenological phases under non-limiting soil water conditions. The experiment was carried out in 2011 in a 1 ha plot in SE Spain with almond trees (Prunus dulcis (Mill.) D.A. Webb cv. 'Marta'). Three crop load treatments were studied according to three crop load levels, i) T100, high crop load, characteristic crop load, ii) T50, medium crop load, in which 50% of the fruits were removed and iii) T0, practically without fruits. Fruits were manually thinned. Each treatment, randomly distributed in blocks, was run in triplicate. Plant water status was assessed from midday stem water potential (Ψs), MDS, daily trunk growth rate (TGR), leaf turgor potential Ψp, fruit water potential (Ψf), stomatal conductance (gs) and photosynthesis (Pn) and transpiration rates (E). Yield, pruning weights and

  4. A research on motion design for APP's loading pages based on time perception

    Science.gov (United States)

    Cao, Huai; Hu, Xiaoyun

    2018-04-01

    Due to restrictions caused by objective reasons like network bandwidth, hardware performance and etc., waiting is still an inevitable phenomenon that appears in our using mobile-terminal products. Relevant researches show that users' feelings in a waiting scenario can affect their evaluations on the whole product and services the product provides. With the development of user experience and inter-facial design subjects, the role of motion effect in the interface design has attracted more and more scholars' attention. In the current studies, the research theory of motion design in a waiting scenario is imperfect. This article will use the basic theory and experimental research methods of cognitive psychology to explore the motion design's impact on user's time perception when users are waiting for loading APP pages. Firstly, the article analyzes the factors that affect waiting experience of loading APP pages based on the theory of time perception, and then discusses motion design's impact on the level of time-perception when loading pages and its design strategy. Moreover, by the operation analysis of existing loading motion designs, the article classifies the existing loading motions and designs an experiment to verify the impact of different types of motions on the user's time perception. The result shows that the waiting time perception of mobile's terminals' APPs is related to the loading motion types, the combination type of loading motions can effectively shorten the waiting time perception as it scores a higher mean value in the length of time perception.

  5. High cycle fatigue of austenitic stainless steels under random loading

    International Nuclear Information System (INIS)

    Gauthier, J.P.; Petrequin, P.

    1987-08-01

    To investigate reactor components, load control random fatigue tests were performed at 300 0 C and 550 0 C, on specimens from austenitic stainless steels plates in the transverse orientation. Random solicitations are produced on closed loop servo-hydraulic machines by a mini computer which generates random load sequence by the use of reduced Markovian matrix. The method has the advantage of taking into account the mean load for each cycle. The solicitations generated are those of a stationary gaussian process. Fatigue tests have been mainly performed in the endurance region of fatigue curve, with scattering determination using stair case method. Experimental results have been analysed aiming at determining design curves for components calculations, depending on irregularity factor and temperature. Analysis in term of mean square root fatigue limit calculation, shows that random loading gives more damage than constant amplitude loading. Damage calculations following Miner rule have been made using the probability density function for the case where the irregularity factor is nearest to 100 %. The Miner rule is too conservative for our results. A method using design curves including random loading effects with irregularity factor as an indexing parameter is proposed

  6. Depressive symptoms are associated with allostatic load among community-dwelling older adults.

    Science.gov (United States)

    Kobrosly, Roni W; van Wijngaarden, Edwin; Seplaki, Christopher L; Cory-Slechta, Deborah A; Moynihan, Jan

    2014-01-17

    The allostatic load model has been used to quantify the physiological costs of the body's response to repeated stressful demands and may provide a useful, integrative perspective on the various correlates of late-life depressive symptoms. We interviewed 125 Rochester, NY adults, ranging in age from 67 to 94 years. We employed an allostatic load score as a measure of multisystem dysfunction in hypothalamic–pituitary–adrenal axis function, immune function, anabolic activity, and cardiovascular activity. Overall, affective, and somatic depressive symptom scores were computed using the 20-item Center for Epidemiologic Studies Depression Scale. Multiple linear regression models were used to estimate associations between allostatic load scores and affective, somatic, and overall depressive symptoms. Among our sample of mean age 76.1 years, the one-week prevalence of clinically significant depressive symptoms was 12.8%. In models adjusting for demographic, socioeconomic, and health-related factors, higher allostatic load scores were associated with elevated scores for overall, affective, and somatic depressive symptoms: beta = 1.21 (95% CI = 0.38, 2.05); beta = 0.14 (95% CI = 0.040, 0.24); beta = 0.60 (95% CI = 0.23, 0.97), respectively. Our results suggest that allostatic load measure is associated with late-life depressive symptoms. This association appears to be of clinical significance, as the magnitude of the effect size was comparable (but opposite in direction) to that of antidepressant use. Future research should examine the inter-relationships of allostatic load, psychological stress, and late-life depressive symptoms.

  7. Load forecasting method considering temperature effect for distribution network

    Directory of Open Access Journals (Sweden)

    Meng Xiao Fang

    2016-01-01

    Full Text Available To improve the accuracy of load forecasting, the temperature factor was introduced into the load forecasting in this paper. This paper analyzed the characteristics of power load variation, and researched the rule of the load with the temperature change. Based on the linear regression analysis, the mathematical model of load forecasting was presented with considering the temperature effect, and the steps of load forecasting were given. Used MATLAB, the temperature regression coefficient was calculated. Using the load forecasting model, the full-day load forecasting and time-sharing load forecasting were carried out. By comparing and analyzing the forecast error, the results showed that the error of time-sharing load forecasting method was small in this paper. The forecasting method is an effective method to improve the accuracy of load forecasting.

  8. Refined shear correction factor for very thick simply supported and uniformly loaded isosceles right triangular auxetic plates

    International Nuclear Information System (INIS)

    Lim, Teik-Cheng

    2016-01-01

    For moderately thick plates, the use of First order Shear Deformation Theory (FSDT) with a constant shear correction factor of 5/6 is sufficient to take into account the plate deflection arising from transverse shear deformation. For very thick plates, the use of Third order Shear Deformation Theory (TSDT) is preferred as it allows the shear strain distribution to be varied through the plate thickness. Therefore no correction factor is required in TSDT, unlike FSDT. Due to the complexity involved in TSDT, this paper obtains a more accurate shear correction factor for use in FSDT of very thick simply supported and uniformly loaded isosceles right triangular plates based on the TSDT. By matching the maximum deflections for this plate according to FSDT and TSDT, a variable shear correction factor is obtained. Results show that the shear correction factor for the simplified TSDT, i.e. 14/17, is least accurate. The commonly adopted shear correction factor of 5/6 in FSDT is valid only for very thin or highly auxetic plates. This paper provides a variable shear correction for FSDT deflection that matches the plate deflection by TSDT. This variable shear correction factor allows designers to justify the use of a commonly adopted shear correction factor of 5/6 even for very thick plates as long as the Poisson’s ratio of the plate material is sufficiently negative. (paper)

  9. Intellectual Leadership of Researchers in Higher Education: Relationship Between the Demographic Factors and Roles (Lithuanian Context

    Directory of Open Access Journals (Sweden)

    Žydžiūnaitė Vilma

    2016-12-01

    Full Text Available The intellectual leadership of educators or teachers represents a topic of a great interest for educational research and practice. Variety of variables or factors have been examined to find the most complete explanations for teachers’, professors’ and educators’ roles, for example, institutional, financial, gender, organizational, spiritual, and intellectual. No literature was found on the relationship between the demographic variables and researchers’ roles in higher education regarding intellectual leadership. But a lot of studies are focused on the relationship between demographic and other factors in education: job satisfaction, organizational justice, religion, gender, culture, personal and professional roles, stress, mental health, and mobility. The research issue in this study is related to researchers’/scientists’ work in higher education schools and is focused on intellectual leadership, which consists of different roles. It is worth to think about researchers as intellectual leaders and to discover how they recognize or identify their roles in higher education. In this study, findings answer the following research question: “What are the relationships between researchers’ roles and their gender, work experience, dissertation defence date, and research field?” The object of the research study is the researchers’ roles in higher education. The aim of the study was to reveal the relationship between demographic factors and researchers’ roles in higher education. Data were collected by performing a questioning survey and using a validated questionnaire with 116 statements in total. The sample consisted of 304 researchers working in higher education institutions. For data analysis, Cronbach’s alpha, Mean and ANOVA calculations were used. The research findings reported that the female-researchers’ evaluations were higher in all cases regarding their roles in higher education schools. The results of the study

  10. The seating mechanics of head-neck modular tapers in vitro: Load-displacement measurements, moisture, and rate effects.

    Science.gov (United States)

    Ouellette, Eric S; Shenoy, Aarti A; Gilbert, Jeremy L

    2018-04-01

    The mechanically assisted crevice corrosion performance of head-neck modular tapers is a significant concern in orthopedic biomaterials. Fretting crevice corrosion processes in modular tapers are thought to be influenced by a wide array of factors including seating mechanics of the junction, hence there is a need for in vitro test methods that can assess their performance. This study presented a test method to directly measure the load-displacement seating mechanics of modular tapers and used this method to compare the seating mechanics for different tapers, moisture, seating loads and seating rates. Seating mechanics were explored whereby the instantaneous load-displacement behavior of the head seating onto the neck is captured and used to define the mechanics of seating. Two distinct taper design/material combinations were assembled wet or dry using axially applied loads (500, 1,000, 2,000, and 4,000 N) at two loading rates of 100 and 10 4  N/s (n = 5 for each condition) using a servohydraulic test frame. The results showed that pull-off strength scaled with seating load and ranged between 43% and 68% of seating load depending on sample and wetness. Tapers seated wet had higher pull-off strengths (2,200 ± 300 N) than those seated dry (1,800 ± 200 N, p mechanics (load-displacement plots) varied due to sample type and due to wetness with differences in seating energy, seating stiffness, and seating displacement. These results show the detailed mechanics of seating during assembly and provide significant insight into the complex interplay of factors associated with even "ideal" seating (axial, quasistatic) loading. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1164-1172, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Infrared thermographic analysis of shape memory polymer during cyclic loading

    International Nuclear Information System (INIS)

    Staszczak, Maria; Pieczyska, Elżbieta A; Maj, Michał; Kukla, Dominik; Tobushi, Hisaaki

    2016-01-01

    In this paper we present the effects of thermomechanical couplings occurring in polyurethane shape memory polymer subjected to cyclic tensile loadings conducted at various strain rates. Stress–strain characteristics were elaborated using a quasistatic testing machine, whereas the specimen temperature changes accompanying the deformation process were obtained with an infrared camera. We demonstrate a tight correlation between the mechanical and thermal results within the initial loading stage. The polymer thermomechanical behaviour in four subsequent loading-unloading cycles and the influence of the strain rate on the stress and the related temperature changes were also examined. In the range of elastic deformation the specimen temperature drops below the initial level due to thermoelastic effect whereas at the higher strains the temperature always increased, due to the dissipative deformation mechanisms. The difference in the characteristics of the specimen temperature has been applied to determine a limit of the polymer reversible deformation and analyzed for various strain rates. It was shown that at the higher strain rates higher values of the stress and temperature changes are obtained, which are related to higher values of the polymer yield points. During the cyclic loading a significant difference between the first and the second cycle was observed. The subsequent loading-unloading cycles demonstrated similar sharply shaped stress and temperature profiles and gradually decrease in values. (paper)

  12. Managing the space-time-load continuum in TMDL planning: a case study for understanding groundwaer loads through advanced mapping techniques

    Science.gov (United States)

    Phillip Harte; Marcel Belaval; Andrea Traviglia

    2016-01-01

    The lag time between groundwater recharge and discharge in a watershed and the potential groundwater load to streams is an important factor in forecasting responses to future land use practices. We call this concept managing the “space-time-load continuum.” It’s understood that in any given watershed, the response function (the load at any given time) will differ for...

  13. Optimizing Preseason Training Loads in Australian Football.

    Science.gov (United States)

    Carey, David L; Crow, Justin; Ong, Kok-Leong; Blanch, Peter; Morris, Meg E; Dascombe, Ben J; Crossley, Kay M

    2018-02-01

    To investigate whether preseason training plans for Australian football can be computer generated using current training-load guidelines to optimize injury-risk reduction and performance improvement. A constrained optimization problem was defined for daily total and sprint distance, using the preseason schedule of an elite Australian football team as a template. Maximizing total training volume and maximizing Banister-model-projected performance were both considered optimization objectives. Cumulative workload and acute:chronic workload-ratio constraints were placed on training programs to reflect current guidelines on relative and absolute training loads for injury-risk reduction. Optimization software was then used to generate preseason training plans. The optimization framework was able to generate training plans that satisfied relative and absolute workload constraints. Increasing the off-season chronic training loads enabled the optimization algorithm to prescribe higher amounts of "safe" training and attain higher projected performance levels. Simulations showed that using a Banister-model objective led to plans that included a taper in training load prior to competition to minimize fatigue and maximize projected performance. In contrast, when the objective was to maximize total training volume, more frequent training was prescribed to accumulate as much load as possible. Feasible training plans that maximize projected performance and satisfy injury-risk constraints can be automatically generated by an optimization problem for Australian football. The optimization methods allow for individualized training-plan design and the ability to adapt to changing training objectives and different training-load metrics.

  14. Effect of ski mountaineering track on foot sole loading pattern.

    Science.gov (United States)

    Haselbacher, Matthias; Mader, Katharina; Werner, Maximiliane; Nogler, Michael

    2014-09-01

    Ski mountaineering is becoming a popular sport. The ascending techniques (tracks) can be divided into 3 different groups: flat field, direct ascent, and traversing. This study examines the relationship between different mechanical loads on the foot and the 4 different mountaineering ascending techniques. All subjects used the same pair of ski boots and the same skis while performing the 4 different ascending techniques. An in-shoe dynamic pressure measuring system was used to measure the mechanical load on the foot soles of each ski mountaineer. The foot sole was divided into 6 anatomic sections to measure the different loads in each section. Thirteen men with an average age of 29 years were enrolled in the study. The results showed small, not significant differences in the mechanical foot load in the flat field or in the direct ascent. The average mechanical foot load was highest on the valley side foot while traversing (179 kPa to 117 kPa). The higher load forces were in the medial ball of the foot and the longitudinal aspect of the foot side closer to the hill. The higher impact placed on the valley side foot and the concentration of force placed on the medial ball of the valley side foot suggested the influence of the track on the load pattern of the foot sole. This higher impact may result in upward forces that affect the force distribution in the ankle and knee joints. Copyright © 2014. Published by Elsevier Inc.

  15. Measuring child maltreatment using multi-informant survey data: a higher-order confirmatory factor analysis

    Directory of Open Access Journals (Sweden)

    Giovanni A. Salum

    2016-03-01

    Full Text Available Objective To investigate the validity and reliability of a multi-informant approach to measuring child maltreatment (CM comprising seven questions assessing CM administered to children and their parents in a large community sample. Methods Our sample comprised 2,512 children aged 6 to 12 years and their parents. Child maltreatment (CM was assessed with three questions answered by the children and four answered by their parents, covering physical abuse, physical neglect, emotional abuse and sexual abuse. Confirmatory factor analysis was used to compare the fit indices of different models. Convergent and divergent validity were tested using parent-report and teacher-report scores on the Strengths and Difficulties Questionnaire. Discriminant validity was investigated using the Development and Well-Being Assessment to divide subjects into five diagnostic groups: typically developing controls (n = 1,880, fear disorders (n = 108, distress disorders (n = 76, attention deficit hyperactivity disorder (n = 143 and oppositional defiant disorder/conduct disorder (n = 56. Results A higher-order model with one higher-order factor (child maltreatment encompassing two lower-order factors (child report and parent report exhibited the best fit to the data and this model's reliability results were acceptable. As expected, child maltreatment was positively associated with measures of psychopathology and negatively associated with prosocial measures. All diagnostic category groups had higher levels of overall child maltreatment than typically developing children. Conclusions We found evidence for the validity and reliability of this brief measure of child maltreatment using data from a large survey combining information from parents and their children.

  16. Stress-intensity factor equations for cracks in three-dimensional finite bodies subjected to tension and bending loads

    Science.gov (United States)

    Newman, J. C., Jr.; Raju, I. S.

    1984-01-01

    Stress intensity factor equations are presented for an embedded elliptical crack, a semielliptical surface crack, a quarter elliptical corner crack, a semielliptical surface crack along the bore of a circular hole, and a quarter elliptical corner crack at the edge of a circular hole in finite plates. The plates were subjected to either remote tension or bending loads. The stress intensity factors used to develop these equations were obtained from previous three dimensional finite element analyses of these crack configurations. The equations give stress intensity factors as a function of parametric angle, crack depth, crack length, plate thickness, and, where applicable, hole radius. The ratio of crack depth to plate thickness ranged from 0 to 1, the ratio of crack depth to crack length ranged from 0.2 to 2, and the ratio of hole radius to plate thickness ranged from 0.5 to 2. The effects of plate width on stress intensity variation along the crack front were also included.

  17. Numerical measures of the degree of non-proportionality of multiaxial fatigue loadings

    Directory of Open Access Journals (Sweden)

    A. Bolchoun

    2015-07-01

    Full Text Available The influence of the non-proportional loadings on the fatigue life depends on the material ductility. Ductile materials react with a shortening of lifetime compared to proportional loading conditions. For a semiductile material there is almost no difference between proportional and non-proportional loadings with respect to the fatigue life. Brittle materials show an increase of the lifetime under non-proportional loadings. If fatigue life assessment is performed using stress-based hypotheses, it is a rather difficult task to take into account material ductility correctly, especially the fatigue life reduction as displayed by ductile materials. Most stress-based hypotheses will compute a longer fatigue life under non-proportional loading conditions. There are also hypotheses, which already include quantitative evaluation of the non-proportionality (e.g. EESH, SSCH and MWCM. Anyway in order to improve assessment for ductile materials, some sort of numerical measure for the degree of non-proportionality of the fatigue loading is required. A number of measures of this kind (or non-proportionality factors were proposed in the literature and are discussed here: - the factor used in EESH is a quotient of stress amplitudes integrals, - the factor according to Gaier, which works with a discrete stress tensor values in a scaled stress space, - the factor according to Kanazawa, which makes use of plane-based stress values, - the factor used in MWCM, which exploits stress values in the plane with the highest shear stress amplitude, a new non-proportionality factor, which is based on the correlation between individual stress tensor components, is proposed. General requirements imposed on the non-proportionality factors are discussed and each of the factors is evaluated with respect to these requirements. Also application with the stress-based hypotheses is discussed and illustrated using the experimental data for aluminum and magnesium welded joints under

  18. A quantitative measure for degree of automation and its relation to system performance and mental load.

    Science.gov (United States)

    Wei, Z G; Macwan, A P; Wieringa, P A

    1998-06-01

    In this paper we quantitatively model degree of automation (DofA) in supervisory control as a function of the number and nature of tasks to be performed by the operator and automation. This model uses a task weighting scheme in which weighting factors are obtained from task demand load, task mental load, and task effect on system performance. The computation of DofA is demonstrated using an experimental system. Based on controlled experiments using operators, analyses of the task effect on system performance, the prediction and assessment of task demand load, and the prediction of mental load were performed. Each experiment had a different DofA. The effect of a change in DofA on system performance and mental load was investigated. It was found that system performance became less sensitive to changes in DofA at higher levels of DofA. The experimental data showed that when the operator controlled a partly automated system, perceived mental load could be predicted from the task mental load for each task component, as calculated by analyzing a situation in which all tasks were manually controlled. Actual or potential applications of this research include a methodology to balance and optimize the automation of complex industrial systems.

  19. Ferrite Film Loaded Frequency Selective Metamaterials for Sub-GHz Applications

    Directory of Open Access Journals (Sweden)

    Bo Gao

    2016-12-01

    Full Text Available Electromagnetic metamaterials are constructed with sub-wavelength structures that exhibit particular electromagnetic properties under a certain frequency range. Because the form-factor of the substructures has to be comparable to the wavelength of the operating frequency, few papers have discussed the metamaterials under GHz frequency. In this paper, we developed an innovative method to reduce the resonant frequency of metamaterals. By integrating the meta-structures with ferrite materials of higher permeability, the cell size of the meta-structure can be scaled down. This paper describes the methodology, design, and development of low-profile GHz ferrite loaded metamaterials. A ferrite film with a permeability of 20 could reduce the resonant frequency of metamaterials by up to 50%. A prototype has been fabricated and the measurement data align well with the simulation results. Because of the lowered operational frequency, the proposed ferrite loaded metamaterials offer more flexibility for various sub-GHz microwave applications, such as cloaks, absorbers, and frequency selective surfaces.

  20. Effect of physical property of supporting media and variable hydraulic loading on hydraulic characteristics of advanced onsite wastewater treatment system.

    Science.gov (United States)

    Sharma, Meena Kumari; Kazmi, Absar Ahmad

    2015-01-01

    A laboratory-scale study was carried out to investigate the effects of physical properties of the supporting media and variable hydraulic shock loads on the hydraulic characteristics of an advanced onsite wastewater treatment system. The system consisted of two upflow anaerobic reactors (a septic tank and an anaerobic filter) accommodated within a single unit. The study was divided into three phases on the basis of three different supporting media (Aqwise carriers, corrugated ring and baked clay) used in the anaerobic filter. Hydraulic loadings were based on peak flow factor (PFF), varying from one to six, to simulate the actual conditions during onsite wastewater treatment. Hydraulic characteristics of the system were identified on the basis of residence time distribution analyses. The system showed a very good hydraulic efficiency, between 0.86 and 0.93, with the media of highest porosity at the hydraulic loading of PFF≤4. At the higher hydraulic loading of PFF 6 also, an appreciable hydraulic efficiency of 0.74 was observed. The system also showed good chemical oxygen demand and total suspended solids removal efficiency of 80.5% and 82.3%, respectively at the higher hydraulic loading of PFF 6. Plug-flow dispersion model was found to be the most appropriate one to describe the mixing pattern of the system, with different supporting media at variable loading, during the tracer study.

  1. Creep crack growth by grain boundary cavitation under monotonic and cyclic loading

    Science.gov (United States)

    Wen, Jian-Feng; Srivastava, Ankit; Benzerga, Amine; Tu, Shan-Tung; Needleman, Alan

    2017-11-01

    Plane strain finite deformation finite element calculations of mode I crack growth under small scale creep conditions are carried out. Attention is confined to isothermal conditions and two time histories of the applied stress intensity factor: (i) a monononic increase to a plateau value subsequently held fixed; and (ii) a cyclic time variation. The crack growth calculations are based on a micromechanics constitutive relation that couples creep deformation and damage due to grain boundary cavitation. Grain boundary cavitation, with cavity growth due to both creep and diffusion, is taken as the sole failure mechanism contributing to crack growth. The influence on the crack growth rate of loading history parameters, such as the magnitude of the applied stress intensity factor, the ratio of the applied minimum to maximum stress intensity factors, the loading rate, the hold time and the cyclic loading frequency, are explored. The crack growth rate under cyclic loading conditions is found to be greater than under monotonic creep loading with the plateau applied stress intensity factor equal to its maximum value under cyclic loading conditions. Several features of the crack growth behavior observed in creep-fatigue tests naturally emerge, for example, a Paris law type relation is obtained for cyclic loading.

  2. Field Study of Live Load Distribution Factors and Dynamic Load Allowance on Reinforced Concrete T-Beam Bridges

    National Research Council Canada - National Science Library

    Trimble, Matthew

    2003-01-01

    .... The vehicle under consideration in this study was a U.S. Army Palletized Loading System (PLS) military vehicle. Results from this evaluation were compared to those obtained from a civilian dump truck owned by the Virginia Department of Transportation...

  3. Inhibitors in haemophilia A: a perspective on clotting factor products as a potential contributing factor.

    Science.gov (United States)

    Mathew, P; Dinter, H; Church, N; Humphries, T J; Kulkarni, R

    2016-05-01

    The occurrence of a neutralizing antibody in previously untreated patients (PUPs) with haemophilia A appears to be the result of an intricate interplay of both genetic and environmental factors. Recently, the type of factor VIII (FVIII) product used in the PUPs population has been implicated as a risk factor for inhibitor development. The aim of this review was to explore in a systematic manner potential hypotheses for the product-related findings in these studies (i.e. differences in the expression system of the cell lines used to produce recombinant FVIII [rFVIII], differences in the administered antigen load or changes in clinical practice over time). Review of the available clinical studies illustrates the high degree of variability for the risk of inhibitor development for the same products across different studies. Differences in cell lines or antigen load were not found to provide a reasonable explanation. The possibility of changes in clinical practice over time and patient selection bias (i.e. the preferential use of one product over another in patients at higher risk for inhibitors) offers a potential explanation and should be carefully considered when evaluating the studies. © 2016 The Authors. Haemophilia Published by John Wiley & Sons Ltd.

  4. Assessment of extreme design loads for modern wind turbines using the probabilistic approach

    DEFF Research Database (Denmark)

    Abdallah, Imad

    There is a large drive to reduce the cost of energy of wind energy generators. Various tracks are being considered such as enhanced O&M strategies through condition monitoring, increased manufacturing efficiency through higher production volumes and increased automation, improved resource...... and drag coefficients showed (a) a tangible reduction in the load partial safety factor for a blade and (b) generally a larger impact on extreme loads during power production compared to stand-still. Therefore, the way forward is for wind turbine manufactures to further update the stochastic model...... assessment through turbine-mounted real-time site assessment technologies, improved components reliability by increased laboratory testing, increased number of prototype test turbines before serial production, larger rotor and tower concepts for both onshore and offshore installations, advanced drive train...

  5. Students' educational careers in Higher Education: a search into key factors regarding study outcome

    NARCIS (Netherlands)

    Dr. Cyrille A.C. Van Bragt

    2010-01-01

    Students' educational careers in Higher Education: a search into key factors regarding study outcome One of the political goals of the EU is to develop 'the most competitive knowledge-based economy in the world by 2010'. The Dutch knowledge economy faces an increased demand for highly-educated

  6. Dutch monitor on stress and physical load : risk factors, consequences, and preventive action

    NARCIS (Netherlands)

    Houtman, I.L.D.; Goudswaard, A.; Dhondt, S.; Grinten, M.P. van der; Hildebrandt, V.H.; Poel, E.G.T. van der

    1998-01-01

    Objectives - Due to recent changes in legislation on occupational health and safety, a national monitor on stress and physical load was developed in The Netherlands to monitor (a) risks and consequences of stress and physical load at work, (b) preventive actions in companies to reduce these risks,

  7. Factors controlling stream water nitrate and phosphor loads during precipitation events

    Science.gov (United States)

    Rozemeijer, J.; van der Velde, Y.; van Geer, F.; de Rooij, G. H.; Broers, H.; Bierkens, M. F.

    2009-12-01

    Pollution of surface waters in densely populated areas with intensive land use is a serious threat to their ecological, industrial and recreational utilization. European and national manure policies and several regional and local pilot projects aim at reducing pollution loads to surface waters. For the evaluation of measures, water authorities and environmental research institutes are putting a lot of effort into monitoring surface water quality. Within regional surface water quality monitoring networks, the measurement locations are usually situated in the downstream part of the catchment to represent a larger area. The monitoring frequency is usually low (e.g. monthly), due to the high costs for sampling and analysis. As a consequence, human induced trends in nutrient loads and concentrations in these monitoring data are often concealed by the large variability of surface water quality caused by meteorological variations. Because this natural variability in surface water quality is poorly understood, large uncertainties occur in the estimates of (trends in) nutrient loads or average concentrations. This study aims at uncertainty reduction in the estimates of mean concentrations and loads of N and P from regional monitoring data. For this purpose, we related continuous records of stream water N and P concentrations to easier and cheaper to collect quantitative data on precipitation, discharge, groundwater level and tube drain discharge. A specially designed multi scale experimental setup was installed in an agricultural lowland catchment in The Netherlands. At the catchment outlet, continuous measurements of water quality and discharge were performed from July 2007-January 2009. At an experimental field within the catchment we collected continuous measurements of precipitation, groundwater levels and tube drain discharges. 20 significant rainfall events with a variety of antecedent conditions, durations and intensities were selected for analysis. Singular and

  8. Canadian House Dust Study: Population-based concentrations, loads and loading rates of arsenic, cadmium, chromium, copper, nickel, lead, and zinc inside urban homes

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, Pat E. [Exposure and Biomonitoring Division, Healthy Environments and Consumer Safety Branch, Health Canada, 50 Colombine Driveway, Ottawa, ON, Canada K1A 0K9 (Canada); Department of Earth Sciences, University of Ottawa, 140 Louis Pasteur, Ottawa, ON, Canada K1N 6N5 (Canada); Levesque, Christine [Exposure and Biomonitoring Division, Healthy Environments and Consumer Safety Branch, Health Canada, 50 Colombine Driveway, Ottawa, ON, Canada K1A 0K9 (Canada); Chénier, Marc; Gardner, H. David [Exposure and Biomonitoring Division, Healthy Environments and Consumer Safety Branch, Health Canada, 50 Colombine Driveway, Ottawa, ON, Canada K1A 0K9 (Canada); Department of Earth Sciences, University of Ottawa, 140 Louis Pasteur, Ottawa, ON, Canada K1N 6N5 (Canada); Jones-Otazo, Heather [Regions and Programs Branch, Health Canada, 180 Queen Street West, Toronto, ON, Canada M5V 3L7 (Canada); Petrovic, Sanya [Contaminated Sites Division, Healthy Environments and Consumer Safety Branch, Health Canada, 269 Laurier Ave West, Ottawa, ON, Canada K1A 0K9 (Canada)

    2013-01-15

    The Canadian House Dust Study was designed to obtain nationally representative urban house dust metal concentrations (μg g{sup −1}) and metal loadings (μg m{sup −2}) for arsenic (As), cadmium (Cd), chromium (Cr), copper (Cu), nickel (Ni), lead (Pb), and zinc (Zn). Consistent sampling of active dust of known age and provenance (area sampled) also permitted the calculation of indoor loading rates (mg m{sup −2} day{sup −1} for dust and μg m{sup −2} day{sup −1} for metals) for the winter season (from 2007 to 2010) when houses are most tightly sealed. Geomean/median indoor dust loading rates in homes located more than 2 km away from industry of any kind (9.6/9.1 mg m{sup −2} day{sup −1}; n = 580) were significantly lower (p < .001) than geomean (median) dust loading rates in homes located within 2 km of industry (13.5/13.4 mg m{sup −2} day{sup −1}; n = 421). Proximity to industry was characterized by higher indoor metal loading rates (p < .003), but no difference in dust metal concentrations (.29 ≥ p ≤ .97). Comparisons of non-smokers' and smokers' homes in non-industrial zones showed higher metal loading rates (.005 ≥ p ≤ .038) in smokers' homes, but no difference in dust metal concentrations (.15 ≥ p ≤ .97). Relationships between house age and dust metal concentrations were significant for Pb, Cd and Zn (p < .001) but not for the other four metals (.14 ≥ p ≤ .87). All seven metals, however, displayed a significant increase in metal loading rates with house age (p < .001) due to the influence of higher dust loading rates in older homes (p < .001). Relationships between three measures of metals in house dust – concentration, load, and loading rate – in the context of house age, smoking behavior and urban setting consistently show that concentration data is a useful indicator of the presence of metal sources in the home, whereas dust mass is the overriding influence on metal loadings and loading rates

  9. Simplified analysis of laterally loaded pile groups

    Directory of Open Access Journals (Sweden)

    F.M. Abdrabbo

    2012-06-01

    Full Text Available The response of laterally loaded pile groups is a complicated soil–structure interaction problem. Although fairly reliable methods are developed to predicate the lateral behavior of single piles, the lateral response of pile groups has attracted less attention due to the required high cost and complication implication. This study presents a simplified method to analyze laterally loaded pile groups. The proposed method implements p-multiplier factors in combination with the horizontal modulus of subgrade reaction. Shadowing effects in closely spaced piles in a group were taken into consideration. It is proven that laterally loaded piles embedded in sand can be analyzed within the working load range assuming a linear relationship between lateral load and lateral displacement. The proposed method estimates the distribution of lateral loads among piles in a pile group and predicts the safe design lateral load of a pile group. The benefit of the proposed method is in its simplicity for the preliminary design stage with a little computational effort.

  10. Load Balancing of Parallel Monte Carlo Transport Calculations

    International Nuclear Information System (INIS)

    Procassini, R J; O'Brien, M J; Taylor, J M

    2005-01-01

    The performance of parallel Monte Carlo transport calculations which use both spatial and particle parallelism is increased by dynamically assigning processors to the most worked domains. Since he particle work load varies over the course of the simulation, this algorithm determines each cycle if dynamic load balancing would speed up the calculation. If load balancing is required, a small number of particle communications are initiated in order to achieve load balance. This method has decreased the parallel run time by more than a factor of three for certain criticality calculations

  11. Opportunities to improve the conversion of food waste to lactate: Fine-tuning secondary factors.

    Science.gov (United States)

    RedCorn, Raymond; Engelberth, Abigail S

    2017-11-01

    Extensive research has demonstrated the potential for bioconversion of food waste to lactate, with major emphasis on adjusting temperature, pH, and loading rate of the fermentation. Each of these factors has a significant effect on lactate production; however, additional secondary factors have received little attention. Here we investigate three additional factors where opportunities exist for process improvement: freezing of samples during storage, discontinuous pH control, and holdover of fermentation broth between fermentations. Freezing samples prior to fermentation was shown to reduce the production rate of lactate by 8%, indicating freeze-thaw should be avoided in experiments. Prior work indicated a trade-off in pH control strategies, where discontinuous pH control correlated with higher lactate accumulation while continuous pH control correlated with higher production rate. Here we demonstrate that continuous pH control can achieve both higher lactate accumulation and higher production rate. Finally, holding over fermentation broth was shown to be a simple method to improve production rate (by 18%) at high food waste loading rates (>140 g volatile solids L -1 ) but resulted in lower lactate accumulation (by 17%). The results inform continued process improvements within the waste treatment of food waste through fermentation to lactic acid.

  12. Influence of sampling frequency and load calculation methods on quantification of annual river nutrient and suspended solids loads.

    Science.gov (United States)

    Elwan, Ahmed; Singh, Ranvir; Patterson, Maree; Roygard, Jon; Horne, Dave; Clothier, Brent; Jones, Geoffrey

    2018-01-11

    Better management of water quality in streams, rivers and lakes requires precise and accurate estimates of different contaminant loads. We assessed four sampling frequencies (2 days, weekly, fortnightly and monthly) and five load calculation methods (global mean (GM), rating curve (RC), ratio estimator (RE), flow-stratified (FS) and flow-weighted (FW)) to quantify loads of nitrate-nitrogen (NO 3 - -N), soluble inorganic nitrogen (SIN), total nitrogen (TN), dissolved reactive phosphorus (DRP), total phosphorus (TP) and total suspended solids (TSS), in the Manawatu River, New Zealand. The estimated annual river loads were compared to the reference 'true' loads, calculated using daily measurements of flow and water quality from May 2010 to April 2011, to quantify bias (i.e. accuracy) and root mean square error 'RMSE' (i.e. accuracy and precision). The GM method resulted into relatively higher RMSE values and a consistent negative bias (i.e. underestimation) in estimates of annual river loads across all sampling frequencies. The RC method resulted in the lowest RMSE for TN, TP and TSS at monthly sampling frequency. Yet, RC highly overestimated the loads for parameters that showed dilution effect such as NO 3 - -N and SIN. The FW and RE methods gave similar results, and there was no essential improvement in using RE over FW. In general, FW and RE performed better than FS in terms of bias, but FS performed slightly better than FW and RE in terms of RMSE for most of the water quality parameters (DRP, TP, TN and TSS) using a monthly sampling frequency. We found no significant decrease in RMSE values for estimates of NO 3 - N, SIN, TN and DRP loads when the sampling frequency was increased from monthly to fortnightly. The bias and RMSE values in estimates of TP and TSS loads (estimated by FW, RE and FS), however, showed a significant decrease in the case of weekly or 2-day sampling. This suggests potential for a higher sampling frequency during flow peaks for more precise

  13. Combined impact of transient heat loads and steady-state plasma exposure on tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Alexander, E-mail: A.Huber@fz-juelich.de [Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung, 52425 Jülich (Germany); Wirtz, Marius; Sergienko, Gennady; Steudel, Isabel [Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung, 52425 Jülich (Germany); Arakcheev, Aleksey; Burdakov, Aleksander [Budker Institute of Nuclear Physics (BINP), Novosibirsk 630090 (Russian Federation); Esser, Hans Guenter; Freisinger, Michaele; Kreter, Arkadi; Linke, Jochen; Linsmeier, Christian; Mertens, Philippe; Möller, Sören; Philipps, Volker; Pintsuk, Gerald; Reinhart, Michael; Schweer, Bernd [Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung, 52425 Jülich (Germany); Shoshin, Andrey [Budker Institute of Nuclear Physics (BINP), Novosibirsk 630090 (Russian Federation); Terra, Alexis; Unterberg, Bernhard [Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung, 52425 Jülich (Germany)

    2015-10-15

    Highlights: • W-samples under combined loading conditions show a lower damage threshold. • The pre-loaded W-samples show a lower damage threshold due to the D- embrittlement. • Pronounced increase of the D retention has been observed during the combined loads. • Enhanced blister formation has been observed under combined loading conditions. - Abstract: Cracking thresholds and crack patterns in tungsten targets have been studied in recent experiments after repetitive ITER-like ELM heat pulses in combination with plasma exposure in PSI-2 (Γ{sub target} = 2.5–4.0 × 10{sup 21} m{sup −2} s{sup −1}, ion energy on surface E{sub ion} = 60 eV, T{sub e} ≈ 10 eV). The heat pulses were simulated by laser irradiation. A Nd:YAG laser with energy per pulse of up to 32 J and a duration of 1 ms at the fundamental wavelength (λ = 1064 nm, repetition rate 0.5 Hz) was used to irradiate ITER-grade W samples with repetitive heat loads. In contrast to pure thermal exposure with a laser beam where the damage threshold under pure heat loads for ITER-grade W lies between 0.38 and 0.76 GW/m{sup 2}, the experiments with pre-loaded W-samples as well as under combined loading conditions show a lower damage threshold of 0.3 GW/m{sup 2}. This is probably due to deuterium embrittlement and/or a higher defect concentration in a region close to the surface due to supersaturation with deuterium. A pronounced increase in the D retention (more than a factor of five) has been observed during the combined transient heat loads and plasma exposure. Enhanced blister formation has been observed under these combined loading conditions.

  14. Combined impact of transient heat loads and steady-state plasma exposure on tungsten

    International Nuclear Information System (INIS)

    Huber, Alexander; Wirtz, Marius; Sergienko, Gennady; Steudel, Isabel; Arakcheev, Aleksey; Burdakov, Aleksander; Esser, Hans Guenter; Freisinger, Michaele; Kreter, Arkadi; Linke, Jochen; Linsmeier, Christian; Mertens, Philippe; Möller, Sören; Philipps, Volker; Pintsuk, Gerald; Reinhart, Michael; Schweer, Bernd; Shoshin, Andrey; Terra, Alexis; Unterberg, Bernhard

    2015-01-01

    Highlights: • W-samples under combined loading conditions show a lower damage threshold. • The pre-loaded W-samples show a lower damage threshold due to the D- embrittlement. • Pronounced increase of the D retention has been observed during the combined loads. • Enhanced blister formation has been observed under combined loading conditions. - Abstract: Cracking thresholds and crack patterns in tungsten targets have been studied in recent experiments after repetitive ITER-like ELM heat pulses in combination with plasma exposure in PSI-2 (Γ_t_a_r_g_e_t = 2.5–4.0 × 10"2"1 m"−"2 s"−"1, ion energy on surface E_i_o_n = 60 eV, T_e ≈ 10 eV). The heat pulses were simulated by laser irradiation. A Nd:YAG laser with energy per pulse of up to 32 J and a duration of 1 ms at the fundamental wavelength (λ = 1064 nm, repetition rate 0.5 Hz) was used to irradiate ITER-grade W samples with repetitive heat loads. In contrast to pure thermal exposure with a laser beam where the damage threshold under pure heat loads for ITER-grade W lies between 0.38 and 0.76 GW/m"2, the experiments with pre-loaded W-samples as well as under combined loading conditions show a lower damage threshold of 0.3 GW/m"2. This is probably due to deuterium embrittlement and/or a higher defect concentration in a region close to the surface due to supersaturation with deuterium. A pronounced increase in the D retention (more than a factor of five) has been observed during the combined transient heat loads and plasma exposure. Enhanced blister formation has been observed under these combined loading conditions.

  15. Epstein-Barr viral load before a liver transplant in children with chronic liver disease.

    Science.gov (United States)

    Shakibazad, Nader; Honar, Naser; Dehghani, Seyed Mohsen; Alborzi, Abdolvahab

    2014-12-01

    Many children with chronic liver disease require a liver transplant. These patients are prone to various infections, including Epstein-Barr virus infection. This study sought to measure the Epstein-Barr viral load by polymerase chain reaction before a liver transplant. This cross-sectional study was done at the Shiraz University of Medical Sciences, Shiraz, Iran, in 2011. All patients were aged younger than 18 years with chronic liver disease and were candidates for a liver transplant at the Shiraz Nemazee Hospital Organ Transplant Center. They had been investigated regarding their demographic characteristics, underlying disease, laboratory findings, and Epstein-Barr viral load by real-time TaqMan polymerase chain reaction. Ninety-eight patients were studied and the mean age was 6.5 ± 5.9 years. Cryptogenic cirrhosis was the most-prevalent reason for liver transplant, and the death rate before a transplant was 15%. Among the study subjects, 6 had measurable Epstein-Barr viral load by polymerase chain reaction before the transplant, and 4 of them had considerably higher Epstein-Barr viral loads (more than 1000 copies/mL). With respect to the close prevalence of posttransplant lymphoproliferative disease (6%) and the high Epstein-Barr viral load in the patients before a transplant (4%), high pretransplant Epstein-Barr viral load can be considered a risk factor for posttransplant lymphoproliferative disorder.

  16. Employee Retention Factors For South African Higher Education Institutions: A Case Study

    Directory of Open Access Journals (Sweden)

    F. G. Netswera

    2005-11-01

    Full Text Available The success of the most competitive companies throughout the world, including higher education institutions, lies in their highly skilled employees on which these institutions spend millions to retain. Literature reveals the cost of losing best employees to be enormous – beyond monetary quantification. Also worth noting is that the loss of one competent employee to a competitor institution strengthens the competitor’s advantage. This case study analysed human resources turnover data, and interviewed academic managers and employees in order to examine the possible employee retention factors for a higher education institution in South Africa. The findings reveal different institutional interests between institutional managers and employees. The former are concerned more about profits, business sustenance and justification for spending, while the latter are driven by introverted interests such as development, monetary rewards and personal fulfilment.

  17. Keeping an eye on the ring: COMS plaque loading optimization for improved dose conformity and homogeneity.

    Science.gov (United States)

    Gagne, Nolan L; Cutright, Daniel R; Rivard, Mark J

    2012-09-01

    To improve tumor dose conformity and homogeneity for COMS plaque brachytherapy by investigating the dosimetric effects of varying component source ring radionuclides and source strengths. The MCNP5 Monte Carlo (MC) radiation transport code was used to simulate plaque heterogeneity-corrected dose distributions for individually-activated source rings of 14, 16 and 18 mm diameter COMS plaques, populated with (103)Pd, (125)I and (131)Cs sources. Ellipsoidal tumors were contoured for each plaque size and MATLAB programming was developed to generate tumor dose distributions for all possible ring weighting and radionuclide permutations for a given plaque size and source strength resolution, assuming a 75 Gy apical prescription dose. These dose distributions were analyzed for conformity and homogeneity and compared to reference dose distributions from uniformly-loaded (125)I plaques. The most conformal and homogeneous dose distributions were reproduced within a reference eye environment to assess organ-at-risk (OAR) doses in the Pinnacle(3) treatment planning system (TPS). The gamma-index analysis method was used to quantitatively compare MC and TPS-generated dose distributions. Concentrating > 97% of the total source strength in a single or pair of central (103)Pd seeds produced the most conformal dose distributions, with tumor basal doses a factor of 2-3 higher and OAR doses a factor of 2-3 lower than those of corresponding uniformly-loaded (125)I plaques. Concentrating 82-86% of the total source strength in peripherally-loaded (131)Cs seeds produced the most homogeneous dose distributions, with tumor basal doses 17-25% lower and OAR doses typically 20% higher than those of corresponding uniformly-loaded (125)I plaques. Gamma-index analysis found > 99% agreement between MC and TPS dose distributions. A method was developed to select intra-plaque ring radionuclide compositions and source strengths to deliver more conformal and homogeneous tumor dose distributions than

  18. +Gz load and executive functions.

    Science.gov (United States)

    Biernacki, Marcin P; Tarnowski, Adam; Lengsfeld, Kamila; Lewkowicz, Rafał; Kowalczuk, Krzysztof; Dereń, Miroslaw

    2013-05-01

    Pilots are constantly exposed to a number of environmental factors, which include +Gz load. Physiological changes evoked by +Gz stimuli have already been well investigated in aviation medicine. However, the influence of +Gz stimulation on executive functions in pilots has not yet been thoroughly explored. There were 20 pilot cadets between the ages of 19 and 22 yr who volunteered to participate in the experiment. The subjects were divided into two groups: the G-load group, which was exposed to accelerations in the centrifuge, and the control group, which did not undergo this stimulation. Executive functions were assessed by means of the Schulte tables and the Rey-Osterrieth complex figure test. +Gz load exposure significantly improved attention switching. This relationship was valid for performance speed (M = 268.09 s in the pretest in the G-load group; M = 228.09 s in the posttest in the G-load group) and for the cumulative time of mistakes (M = 26.73 s in the pretest in the G-load group; M = 12 s in the posttest in the G-load group), whereas reproduction of visuospatial stimuli from memory deteriorated significantly under the influence of +Gz stimulation (M = 17.18 points in the posttest in the G-load group; M = 28.18 points in the posttest in the control group). These results suggest that the impact of +Gz load is not homogenous and unidirectional, since it improves attention switching but visuospatial working memory decreases under its influence. These aspects are particularly important for understanding the mechanisms responsible for maintaining situational awareness during the flight.

  19. Enhanced sensitivity fibre Bragg grating (FBG) load sensor

    International Nuclear Information System (INIS)

    Correia, Ricardo; Chehura, Edmon; Li, Jin; James, Stephen W; Tatam, Ralph P

    2010-01-01

    The characterization of a load sensor based on the transverse loading of a subsection of a fibre Bragg grating (FBG) embedded within a cube of epoxy resin is presented. When the epoxy resin cube is loaded transverse to the axis of the fibre, its deformation transduces the load to a strain along the axis of the optical fibre, which changes the period of the embedded section of the FBG. This creates a spectral dropout within the bandwidth of the FBG, with an absolute wavelength that is linearly dependent on the applied load. This technique enhances the sensitivity of the FBG to transverse loading by a factor of 15, to 2.9 × 10 −2 ± 0.01 nm N −1 , when compared to the direct transverse loading of a bare fibre, and also protects the fibre from mechanical damage at the loading point

  20. Investigation of R-Factor for steel moment frame combined with cold-formed steel structures under different load patterns using pushover analysis

    Directory of Open Access Journals (Sweden)

    Siavash Sadeghi

    2017-08-01

    Full Text Available The use of Lightweight Steel Frames (LSF has grown considerably in recent years all over the world due to its unique advantages such as being cost-effective and light-weight, easy and quick installment. Another application is to use them in order to increase the number of new floors on the existing buildings. But since the behavior of the combined structure is not clear, there is no possibility of increasing new floors with Lightweight Steel Frames. Therefore, through selecting and modeling three buildings of three, five and seven floors with steel moment frames in SAP2000 software and adding one or two new floors using Lightweight Steel Frames (LSF and conducting a non-linear static analysis with three different lateral load pattern, we dealt with the seismic behavior and determined the behavior coefficient of each of the combined structures. The results indicated that the use of cold-formed structures in order to add story do not have a significant impact on R-factor. In addition, R-factor depends on the type of the side loading pattern.

  1. FACTORS CAUSING OCCUPATIONAL STRESS AMONG SENIOR SECONDARY SCHOOL TEACHERS OF AMRITSAR DISTRICT

    Directory of Open Access Journals (Sweden)

    Mandeep Singh

    2009-12-01

    Full Text Available The study attempts to investigate the various factors causing occupational stress experienced by senior secondary school teachers. A sample of 100 teachers (50 science teachers and 50 physical education teachers was randomly selected. They were administered a comprehensive questionnaire which measures various factors of stress. Factor analyses were used to identify underlying factors causing stress. The analysis showed that non cooperation from the colleagues, hastiness to finish the work, unable to perform duty smoothly, unclear instructions and insufficient facilities, unclear expectations of higher authority and having more work load in less time were the significant factors causing occupational stress among the teachers. The monotonous nature of work, ignorance of higher authority and violation of administrative processes and policies were factors also contributing towards occupational stress among teachers

  2. Combustion and emissions characteristics of diesel engine fueled by biodiesel at partial load conditions

    International Nuclear Information System (INIS)

    An, H.; Yang, W.M.; Chou, S.K.; Chua, K.J.

    2012-01-01

    Highlights: ► Impact of engine load on engine’s performance, combustion and emission characteristics. ► The brake specific fuel consumption (BSFC) increases significantly at partial load conditions. ► The brake thermal efficiency (BTE) drops at lower engine loads, and increases at higher loads. ► The partial load also influences the trend of CO emissions. -- Abstract: This paper investigated the performance, combustion and emission characteristics of diesel engine fueled by biodiesel at partial load conditions. Experiments were conducted on a common-rail fuel injection diesel engine using ultra low sulfur diesel, biodiesel (B100) and their blend fuels of 10%, 20%, 50% (denoted as B10, B20 and B50 respectively) under various loads. The results show that biodiesel/blend fuels have significant impacts on the engine’s brake specific fuel consumption (BSFC) and brake thermal efficiency (BTE) at partial load conditions. The increase in BSFC for B100 is faster than that of pure diesel with the decrease of engine load. A largest increase of 28.1% in BSFC is found at 10% load. Whereas for BTE, the results show that the use of biodiesel results in a reduced thermal efficiency at lower engine loads and improved thermal efficiency at higher engine loads. Furthermore, the characteristics of carbon monoxide (CO) emissions are also changed at partial load conditions. When running at lower engine loads, the CO emission increases with the increase of biodiesel blend ratio and the decrease of engine speed. However, at higher engine loads, an opposite trend is obtained.

  3. Post-load hyperglycaemia and diagnostic criteria for diabetes

    Institute of Scientific and Technical Information of China (English)

    Qing Qiao

    2008-01-01

    The evolution of 2 h post-load glucose tolerance test for diagnosis of diabetes and its clinical implication was reviewed and discussed.Post-load hyperglycemia is a risk factor for both micro-and macro-vascular diseases.According to its relationship with retinopathy,the current cut-off values for diabetes was defined since 1979.Recently,strong evidence has shown that post-load hyperglycemia is also an important risk factor for cardiovascular disease(CVD),the relation is linear and no a threshold was found.There are large discrepancies between fasting and 2 h glucose criteria in the classification of diabetes and impaired glucose tolerance(IGT)/impaired fasting glucose(IFG).For early diagnosis and intervention administrating a 2 h OGTT to suspect individuals is necessary.

  4. Numerical Loading of a Maxwellian Probability Distribution Function

    International Nuclear Information System (INIS)

    Lewandowski, J.L.V.

    2003-01-01

    A renormalization procedure for the numerical loading of a Maxwellian probability distribution function (PDF) is formulated. The procedure, which involves the solution of three coupled nonlinear equations, yields a numerically loaded PDF with improved properties for higher velocity moments. This method is particularly useful for low-noise particle-in-cell simulations with electron dynamics

  5. Is the internal training load different between starters and nonstarters volleyball players submitted to the same external load training? A case study

    Directory of Open Access Journals (Sweden)

    Thiago Andrade Goulart Horta

    2017-11-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2017v19n4p395   The same training stimulus can provide different physiological adaptations for athletes of the same team. Thus, the aim of this study was to analyze and compare the load training of starters and nonstarters players, athletes of a men’s volleyball team at different times of the season. The sample consisted of fifteen men’s volleyball superleague athletes who were divided into two groups of starters and nonstarters players. The training load of the ten weeks of the team’s preparation period for the main championship season in which no games were performed was selected for the study. The method of subjective perceived of effort (session-RPE proposed by Foster et al. (2001 was used to quantify the training load. The group of starters players had higher total weekly training load (TWTL and RPE values in the average of the ten weeks of training (p<0.05. Higher TWTL values for starters players in the preparatory and pre-competitive period compared to nonstarters players was also demonstrated (p<0.05. When different weeks were analyzed separately, weeks three and seven presented higher TWTL and RPE values for starters players compared with nonstarters players (p<0.05. The results presented in this study showed that starters players showed greater internal training load compared to nonstarters players.

  6. Attentional capture under high perceptual load.

    Science.gov (United States)

    Cosman, Joshua D; Vecera, Shaun P

    2010-12-01

    Attentional capture by abrupt onsets can be modulated by several factors, including the complexity, or perceptual load, of a scene. We have recently demonstrated that observers are less likely to be captured by abruptly appearing, task-irrelevant stimuli when they perform a search that is high, as opposed to low, in perceptual load (Cosman & Vecera, 2009), consistent with perceptual load theory. However, recent results indicate that onset frequency can influence stimulus-driven capture, with infrequent onsets capturing attention more often than did frequent onsets. Importantly, in our previous task, an abrupt onset was present on every trial, and consequently, attentional capture might have been affected by both onset frequency and perceptual load. In the present experiment, we examined whether onset frequency influences attentional capture under conditions of high perceptual load. When onsets were presented frequently, we replicated our earlier results; attentional capture by onsets was modulated under conditions of high perceptual load. Importantly, however, when onsets were presented infrequently, we observed robust capture effects. These results conflict with a strong form of load theory and, instead, suggest that exposure to the elements of a task (e.g., abrupt onsets) combines with high perceptual load to modulate attentional capture by task-irrelevant information.

  7. Automatic Power Factor Correction Using Capacitive Bank

    OpenAIRE

    Mr.Anant Kumar Tiwari,; Mrs. Durga Sharma

    2014-01-01

    The power factor correction of electrical loads is a problem common to all industrial companies. Earlier the power factor correction was done by adjusting the capacitive bank manually [1]. The automated power factor corrector (APFC) using capacitive load bank is helpful in providing the power factor correction. Proposed automated project involves measuring the power factor value from the load using microcontroller. The design of this auto-adjustable power factor correction is ...

  8. Load following operation of nuclear power plants for meeting power system requirements

    International Nuclear Information System (INIS)

    Isoda, Hachiro

    1987-01-01

    This paper describes a calculating program on the availability factors of nuclear, thermal and pumed storage hydro power stations and some calculated results for typical three load factors, 55 %, 60 % and 71 %, are provided when the share of the nuclea power station in the generation facilities is increased. The load following requirement of the nuclear power station is also provided. Load following requirement: If there is a 10 % pumped storage hydro power station, the nuclear power station enables to be operated with its rated output up to 30 % - 35 % of its share. Its daily load following operation for 40 % and 50 % nuclear power station needs every weekend and every day respectively. Availability factor: The availability factor of the nuclear power station manages to get 80 % (maximum availability factor of the nuclear power station in this study) up to 30 % share of it with 10 % pumpued storage hydro power station. When the nuclear power station shares 40 % and 50 %, its availability factor decreases down 1 % and 5 % respectively. (author)

  9. Fuel loading and homogeneity analysis of HFIR design fuel plates loaded with uranium silicide fuel

    International Nuclear Information System (INIS)

    Blumenfeld, P.E.

    1995-08-01

    Twelve nuclear reactor fuel plates were analyzed for fuel loading and fuel loading homogeneity by measuring the attenuation of a collimated X-ray beam as it passed through the plates. The plates were identical to those used by the High Flux Isotope Reactor (HFIR) but were loaded with uranium silicide rather than with HFIR's uranium oxide fuel. Systematic deviations from nominal fuel loading were observed as higher loading near the center of the plates and underloading near the radial edges. These deviations were within those allowed by HFIR specifications. The report begins with a brief background on the thermal-hydraulic uncertainty analysis for the Advanced Neutron Source (ANS) Reactor that motivated a statistical description of fuel loading and homogeneity. The body of the report addresses the homogeneity measurement techniques employed, the numerical correction required to account for a difference in fuel types, and the statistical analysis of the resulting data. This statistical analysis pertains to local variation in fuel loading, as well as to ''hot segment'' analysis of narrow axial regions along the plate and ''hot streak'' analysis, the cumulative effect of hot segment loading variation. The data for all twelve plates were compiled and divided into 20 regions for analysis, with each region represented by a mean and a standard deviation to report percent deviation from nominal fuel loading. The central regions of the plates showed mean values of about +3% deviation, while the edge regions showed mean values of about -7% deviation. The data within these regions roughly approximated random samplings from normal distributions, although the chi-square (χ 2 ) test for goodness of fit to normal distributions was not satisfied

  10. Unknown loads affect force production capacity in early phases of bench press throws.

    Science.gov (United States)

    Hernández Davó, J L; Sabido Solana, R; Sarabia Marínm, J M; Sánchez Martos, Á; Moya Ramón, M

    2015-10-01

    Explosive strength training aims to improve force generation in early phases of movement due to its importance in sport performance. The present study examined the influence of lack of knowledge about the load lifted in explosive parameters during bench press throws. Thirteen healthy young men (22.8±2.0 years) participated in the study. Participants performed bench press throws with three different loads (30, 50 and 70% of 1 repetition maximum) in two different conditions (known and unknown loads). In unknown condition, loads were changed within sets in each repetition and participants did not know the load, whereas in known condition the load did not change within sets and participants had knowledge about the load lifted. Results of repeated-measures ANOVA revealed that unknown conditions involves higher power in the first 30, 50, 100 and 150 ms with the three loads, higher values of ratio of force development in those first instants, and differences in time to reach maximal rate of force development with 50 and 70% of 1 repetition maximum. This study showed that unknown conditions elicit higher values of explosive parameters in early phases of bench press throws, thereby this kind of methodology could be considered in explosive strength training.

  11. Retrospective Analysis of Inflight Exercise Loading and Physiological Outcomes

    Science.gov (United States)

    Ploutz-Snyder, L. L.; Buxton, R. E.; De Witt, J. K.; Guilliams, M. E.; Hanson, A. M.; Peters, B. T.; Pandorf, M. M. Scott; Sibonga, J. D.

    2014-01-01

    Astronauts perform exercise throughout their missions to counter the health declines that occur as a result of long-term exposure to weightlessness. Although all astronauts perform exercise during their missions, the specific prescriptions, and thus the mechanical loading, differs among individuals. For example, inflight ground reaction force data indicate that subject-specific differences exist in foot forces created when exercising on the second-generation treadmill (T2) [1]. The current exercise devices allow astronauts to complete prescriptions at higher intensities, resulting in greater benefits with increased efficiency. Although physiological outcomes have improved, the specific factors related to the increased benefits are unknown. In-flight exercise hardware collect data that allows for exploratory analyses to determine if specific performance factors relate to physiological outcomes. These analyses are vital for understanding which components of exercise are most critical for optimal human health and performance. The relationship between exercise performance variables and physiological changes during flight has yet to be fully investigated. Identifying the critical performance variables that relate to improved physiological outcomes is vital for creating current and future exercise prescriptions to optimize astronaut health. The specific aims of this project are: 1) To quantify the exercise-related mechanical loading experienced by crewmembers on T2 and ARED during their mission on ISS; 2) To explore relationships between exercise loading variables, bone, and muscle health changes during the mission; 3) To determine if specific mechanical loading variables are more critical than others in protecting physiology; 4) To develop methodology for operational use in monitoring accumulated training loads during crew exercise programs. This retrospective analysis, which is currently in progress, is being conducted using data from astronauts that have flown long

  12. A Comparison of Load-Velocity and Load-Power Relationships Between Well-Trained Young and Middle-Aged Males During Three Popular Resistance Exercises.

    Science.gov (United States)

    Fernandes, John F T; Lamb, Kevin L; Twist, Craig

    2018-05-01

    Fernandes, JFT, Lamb, KL, and Twist, C. A comparison of load-velocity and load-power relationships between well-trained young and middle-aged males during 3 popular resistance exercises. J Strength Cond Res 32(5): 1440-1447, 2018-This study examined the load-velocity and load-power relationships among 20 young (age 21.0 ± 1.6 years) and 20 middle-aged (age 42.6 ± 6.7 years) resistance-trained males. Participants performed 3 repetitions of bench press, squat, and bent-over-row across a range of loads corresponding to 20-80% of 1 repetition maximum (1RM). Analysis revealed effects (p velocity for all 3 exercises, and interaction effects on power for squat and bent-over-row (p bench press and bent-over-row, the young group produced higher barbell velocities, with the magnitude of the differences decreasing as load increased (ES; effect size 0.0-1.7 and 1.0-2.0, respectively). Squat velocity was higher in the young group than the middle-aged group (ES 1.0-1.7) across all loads, as was power for each exercise (ES 1.0-2.3). For all 3 exercises, both velocity and 1RM were correlated with optimal power in the middle-aged group (r = 0.613-0.825, p velocities at low external loads and power outputs as high as the young males across a range of external resistances. Moreover, the strong correlations between 1RM and velocity with optimal power suggest that middle-aged males would benefit from training methods which maximize these adaptations.

  13. Suspended sediment load in the tidal zone of an Indonesian river

    Directory of Open Access Journals (Sweden)

    F. A. Buschman

    2012-11-01

    Full Text Available Forest clearing for reasons of timber production, open pit mining and the establishment of oil palm plantations generally results in excessively high sediment loads in tropical rivers. The increasing sediment loads pose a threat to coastal marine ecosystems, such as coral reefs. This study presents observations of suspended sediment loads in the Berau River (Kalimantan, Indonesia, which debouches into a coastal ocean that is a preeminent center of coral diversity. The Berau River is relatively small and drains a mountainous, still relatively pristine basin that receives abundant rainfall. In the tidal zone of the Berau River, flow velocity was measured over a large part of the river width using a horizontal acoustic Doppler current profiler (HADCP. Surrogate measurements of suspended sediment concentration were taken with an optical backscatter sensor (OBS. Averaged over the 6.5 weeks covered by the benchmark survey period, the suspended sediment load was estimated at 2 Mt yr−1. Based on rainfall-runoff modeling though, the river discharge peak during the survey was supposed to be moderate and the yearly averaged suspended sediment load is most likely somewhat higher than 2 Mt yr−1. The consequences of ongoing clearing of rainforest were explored using a plot-scale erosion model. When rainforest, which still covered 50–60% of the basin in 2007, is converted to production land, soil loss is expected to increase with a factor between 10 and 100. If this soil loss is transported seaward as suspended sediment, the increase in suspended sediment load in the Berau River would impose a severe stress on this global hotspot of coral reef diversity.

  14. A combined loading system integrated with portable winch and polyethylene chutes for loading of timber products

    Directory of Open Access Journals (Sweden)

    H. Hulusi Acar

    2016-01-01

    Full Text Available Truck loading operation is an important task during timber production operations in forestry. In Turkey, approximately 50 million timbers/logs are being produced per year, and then they are loaded into the logging trucks. The timber/logs are transported over the forest roads with an average of one million roundtrips. However, the traditional loading methods using manpower are mostly performed while some part is done by using loading machines which can be very costly and risky. This study aims developing a combined loading system in which heavy logs are loaded into logging trucks by pulling them by a log-line powered by a portable crane within the chute system. The slope of the log-line from ground to logging truck varied between 1% and 25%. Within the each work cycle of loading operation, only one log was loaded by pulling with portable crane. The average loading time was found as 161.8 seconds per cycle, in which 67% of the time was spent on pulling the log into the logging truck. The results indicated that the average pulling speed with crane power was 840.4 m/hr and productivity was calculated as 4.94 m3/hr. The result on system speed and productivity indicated close relations with results from previous studies. The hydraulic grapple loader or cranes are widely used and common loading machines, but they cannot be efficiently used in forestry operations, especially ones having a low timber productivity rate or having low economic value timber. In these conditions, loading methods that are cost efficient and do not require higher production rate should be employed. Therefore, a combined loading system introduced in this study can be a feasible solution for loading operations in those cases. Furthermore, it is believed that this loading system integrated with a portable crane can be cost efficient and time saving solution, as well as ergonomic and safe method in the field.

  15. Rapid pile load tests in the geotechnical centrifuge

    NARCIS (Netherlands)

    Holscher, P.; Van Tol, A.F.; Huy, N.Q.

    2012-01-01

    Centrifiige experiments were carried out to gain insight into the factors that affect the mobilized resistance during rapid load testing on piles in sand. The influence of generated pore water pressure during rapid load tests is shidied, and its effect on the commonly used unloadmg point method to

  16. Association between increase in vertical ground reaction force loading rate and pain level in women with patellofemoral pain after a patellofemoral joint loading protocol.

    Science.gov (United States)

    Briani, Ronaldo Valdir; Pazzinatto, Marcella Ferraz; Waiteman, Marina Cabral; de Oliveira Silva, Danilo; de Azevedo, Fábio Mícolis

    2018-04-11

    The etiology of patellofemoral pain (PFP) is thought to be the result of increased patellofemoral joint (PFJ) load and aberrant lower extremity mechanics, including altered vertical ground reaction forces (VGRF). However, few studies have investigated the association between an increase in pain and VGRF loading rates in the context of PFP. Thus, this study aimed to investigate the immediate effects of PFJ loading on pain and VGRF loading rate, and to see if there is a link between modification of both pain and VGRF loading rate during stair negotiation. Thirty-four women with PFP underwent VGRF analysis during stair negotiation under two conditions: with (condition 2) and without (condition 1) being previously submitted to a PFJ loading protocol in order to or not to exacerbate their knee pain, respectively. The VGRF loading rates were significantly higher in condition 2 (Mean ± standard deviation (SD)=4.0±0.6N/s) compared to condition 1 (Mean±SD=3.6±0.5N/s) during stair ascent and during stair descent (Mean±SD: condition 1=6.3±1.1N/s; condition 2=7.0±1.4N/s). In addition, VGRF loading rates were higher during stair descent compared to stair ascent in both conditions. There were significant correlations between the increase in pain and VGRF loading rate during both tasks. There seemed to be an important relation between the increase in pain and VGRF loading rates in women with PFP. Based on these findings, interventions aimed at reducing VGRF loading rates are important in the context of PFP. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Differences in the Load-Velocity Profile Between 4 Bench-Press Variants.

    Science.gov (United States)

    García-Ramos, Amador; Pestaña-Melero, Francisco Luis; Pérez-Castilla, Alejandro; Rojas, Francisco Javier; Haff, Guy Gregory

    2018-03-01

    To compare the load-velocity relationship between 4 variants of the bench-press (BP) exercise. The full load-velocity relationship of 30 men was evaluated by means of an incremental loading test starting at 17 kg and progressing to the individual 1-repetition maximum (1RM) in 4 BP variants: concentric-only BP, concentric-only BP throw (BPT), eccentric-concentric BP, and eccentric-concentric BPT. A strong and fairly linear relationship between mean velocity (MV) and %1RM was observed for the 4 BP variants (r 2  > .96 for pooled data and r 2  > .98 for individual data). The MV associated with each %1RM was significantly higher in the eccentric-concentric technique than in the concentric-only technique. The only significant difference between the BP and BPT variants was the higher MV with the light to moderate loads (20-70%1RM) in the BPT using the concentric-only technique. MV was significantly and positively correlated between the 4 BP variants (r = .44-.76), which suggests that the subjects with higher velocities for each %1RM in 1 BP variant also tend to have higher velocities for each %1RM in the 3 other BP variants. These results highlight the need for obtaining specific equations for each BP variant and the existence of individual load-velocity profiles.

  18. Effects of static pre-loading on the dynamic stability of a column on ...

    African Journals Online (AJOL)

    This paper presents, from strictly analytical consideration, the dynamic analysis of a finite column stressed by a step load but in the presence of a previously imposed static load. The results show that (a) the dynamic buckling load for this type of loading is relatively higher than that of a similar column stressed by a step load ...

  19. Drug Loading of Mesoporous Silicon

    Science.gov (United States)

    Moffitt, Anne; Coffer, Jeff; Wang, Mengjia

    2011-03-01

    The nanostructuring of crystalline solids with low aqueous solubilities by their incorporation into mesoporous host materials is one route to improve the bioavailability of such solids. Earlier studies suggest that mesoporous Si (PSi), with pore widths in the range of 5-50 nm, is a candidate for such an approach. In this presentation, we describe efforts to load curcumin into free-standing microparticles of PSi. Curcumin is a compound extracted from turmeric root, which is an ingredient of curry. Curucmin has shown activity against selected cancer cell lines, bacteria, and other medical conditions. However, curcumin has a very low bioavailability due to its extremely low water solubility (0.6 μ g/mL). Incorporation of curcumin was achieved by straightforward loading of the molten solid at 185circ; C. Loading experiments were performed using PSi particles of two different size ranges, 45-75 μ m and 150-250 μ m. Longer loading times and ratio of curcumin to PSi leads to a higher percentage of loaded curcumin in both PSi particle sizes (as determined by weight difference). The extent of curcumin crystallinity was assessed by x-ray diffraction (XRD). The solubility and release kinetics of loaded curcumin from the PSi was determined by extraction into water at 37circ; C, with analysis using UV-VIS spectrometry. NSF-REU and TCU.

  20. Neural effects of cognitive control load on auditory selective attention.

    Science.gov (United States)

    Sabri, Merav; Humphries, Colin; Verber, Matthew; Liebenthal, Einat; Binder, Jeffrey R; Mangalathu, Jain; Desai, Anjali

    2014-08-01

    Whether and how working memory disrupts or alters auditory selective attention is unclear. We compared simultaneous event-related potentials (ERP) and functional magnetic resonance imaging (fMRI) responses associated with task-irrelevant sounds across high and low working memory load in a dichotic-listening paradigm. Participants performed n-back tasks (1-back, 2-back) in one ear (Attend ear) while ignoring task-irrelevant speech sounds in the other ear (Ignore ear). The effects of working memory load on selective attention were observed at 130-210ms, with higher load resulting in greater irrelevant syllable-related activation in localizer-defined regions in auditory cortex. The interaction between memory load and presence of irrelevant information revealed stronger activations primarily in frontal and parietal areas due to presence of irrelevant information in the higher memory load. Joint independent component analysis of ERP and fMRI data revealed that the ERP component in the N1 time-range is associated with activity in superior temporal gyrus and medial prefrontal cortex. These results demonstrate a dynamic relationship between working memory load and auditory selective attention, in agreement with the load model of attention and the idea of common neural resources for memory and attention. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. SPEAR 2 RF SYSTEM LOADS

    International Nuclear Information System (INIS)

    2002-01-01

    The design and performance of higher order mode (HOM) dampers for the SPEAR 2 RF system is presented. The SPEAR beam had experienced occasional periods of instability due to transverse oscillations which were driven by HOMs in the RF cavities. A substantial fraction of this RF energy was coupled out of the cavity into the waveguide connecting the cavity to the klystron. This waveguide was modified by adding a stub of smaller cross section, terminated by a ferrite tile load, to the system. Design considerations of the load, and its effect on HOMs and beam stability will be discussed

  2. Generalized Analytical Program of Thyristor Phase Control Circuit with Series and Parallel Resonance Load

    OpenAIRE

    Nakanishi, Sen-ichiro; Ishida, Hideaki; Himei, Toyoji

    1981-01-01

    The systematic analytical method is reqUired for the ac phase control circuit by means of an inverse parallel thyristor pair which has a series and parallel L-C resonant load, because the phase control action causes abnormal and interesting phenomena, such as an extreme increase of voltage and current, an unique increase and decrease of contained higher harmonics, and a wide variation of power factor, etc. In this paper, the program for the analysis of the thyristor phase control circuit with...

  3. Intrinsic and Extrinsic Factors That Influence Black Males to Attend Institutions of Higher Education

    Science.gov (United States)

    Etheridge, Robert

    2013-01-01

    The purpose of this qualitative, narrative study was to explore the intrinsic and extrinsic factors that motivated Black males to attend institutions of higher education. The Self-determination theory and the Integrated Model for Educational Choice formed the theoretical framework for this study. Eight Black males who were between the ages of 18…

  4. Mechanical properties of stanene under uniaxial and biaxial loading: A molecular dynamics study

    Energy Technology Data Exchange (ETDEWEB)

    Mojumder, Satyajit [Department of Mechanical Engineering, Bangladesh University of Engineering and Technology, Dhaka 1000 (Bangladesh); Amin, Abdullah Al [Department of Mechanical and Aerospace Engineering, Case western Reverse University, Cleveland, Ohio 44106 (United States); Islam, Md Mahbubul, E-mail: mmi122@psu.edu [Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802 (United States)

    2015-09-28

    Stanene, a graphene like two dimensional honeycomb structure of tin has attractive features in electronics application. In this study, we performed molecular dynamics simulations using modified embedded atom method potential to investigate mechanical properties of stanene. We studied the effect of temperature and strain rate on mechanical properties of α-stanene for both uniaxial and biaxial loading conditions. Our study suggests that with the increasing temperature, both the fracture strength and strain of the stanene decrease. Uniaxial loading in zigzag direction shows higher fracture strength and strain compared to the armchair direction, while no noticeable variation in the mechanical properties is observed for biaxial loading. We also found at a higher loading rate, material exhibits higher fracture strength and strain. These results will aid further investigation of stanene as a potential nano-electronics substitute.

  5. Variation of parasite load and immune parameters in two species of New Zealand shore crabs.

    Science.gov (United States)

    Dittmer, Jessica; Koehler, Anson V; Richard, Freddie-Jeanne; Poulin, Robert; Sicard, Mathieu

    2011-09-01

    While parasites are likely to encounter several potential intermediate hosts in natural communities, a parasite's actual range of compatible hosts is limited by numerous biological factors ranging from behaviour to immunology. In crustaceans, two major components of immunity are haemocytes and the prophenoloxidase system involved in the melanisation of foreign particles. Here, we analysed metazoan parasite prevalence and loads in the two sympatric crab species Hemigrapsus crenulatus and Macrophthalmus hirtipes at two sites. In parallel, we analysed the variation in haemocyte concentration and amount of circulating phenoloxidase (PO) in the haemolymph of the same individuals in an attempt to (a) explain differences in parasite prevalence and loads in the two species at two sites and (b) assess the impact of parasites on these immune parameters. M. hirtipes harboured more parasites but also exhibited higher haemocyte concentrations than H. crenulatus independent of the study site. Thus, higher investment in haemocyte production for M. hirtipes does not seem to result in higher resistance to parasites. Analyses of variation in immune parameters for the two crab species between the two sites that differed in parasite prevalence showed common trends. (a) In general, haemocyte concentrations were higher at the site experiencing higher parasitic pressure while circulating PO activity was lower and (b) haemocyte concentrations were influenced by microphallid trematode metacercariae in individuals from the site with higher parasitic pressure. We suggest that the higher haemocyte concentrations observed in both crab species exposed to higher parasitic pressure may represent an adaptive response to the impact of parasites on this immune parameter.

  6. [Optimization on trehalose loading technique as protective conditioning for lyophilization of human platelets].

    Science.gov (United States)

    Liu, Jing-Han; Zhou, Jun; Ouyang, Xi-Lin; Li, Xi-Jin; Lu, Fa-Qiang

    2005-08-01

    This study was aimed to further optimize trehalose loading technique including loading temperature, loading time, loading solution and loading concentration of trehalose, based on the established parameters. Loading efficiency in plasma was compared with that in buffer at 37 degrees C; the curves of intracellular trehalose concentration versus loading time at 37 degrees C and 16 degrees C were measured; curves of mean platelet volume (MPV) versus loading time and loading concentration were investigated and compared. According to results obtained, the loaing time, loading temperature, loading solution and trehalose concentration were ascertained for high loading efficiency of trehalose into human platelet. The results showed that the loading efficiency in plasma was markedly higher than that in buffer at 37 degrees C, the loading efficiency in plasma at 37 degrees C was significantly higher than that at 16 degrees C and reached 19.51% after loading for 4 hours, but 6.16% at 16 degrees C. MPV at 16 degrees C was increased by 43.2% than that at 37 degrees C, but had no distinct changes with loading time and loading concentration. In loading at 37 degrees C, MPV increased with loading time and loading concentration positively. Loading time and loading concentration displayed synergetic effect on MPV. MPV increased with loading time and concentration while trehalose loading concentration was above 50 mmol/L. It is concluded that the optimization parameters of trehalose loading technique are 37 degrees C (temperature), 4 hours (leading time), plasma (loading solution), 50 mmol/L (feasible trehalose concentration). The trehalose concentration can be adjusted to meet the requirement of lyophilization.

  7. Upper Limb Muscle and Brain Activity in Light Assembly Task on Different Load Levels

    Science.gov (United States)

    Zadry, Hilma Raimona; Dawal, Siti Zawiah Md.; Taha, Zahari

    2010-10-01

    A study was conducted to investigate the effect of load on upper limb muscles and brain activities in light assembly task. The task was conducted at two levels of load (Low and high). Surface electromyography (EMG) was used to measure upper limb muscle activities of twenty subjects. Electroencephalography (EEG) was simultaneously recorded with EMG to record brain activities from Fz, Pz, O1 and O2 channels. The EMG Mean Power Frequency (MPF) of the right brachioradialis and the left upper trapezius activities were higher on the high-load task compared to low-load task. The EMG MPF values also decrease as time increases, that reflects muscle fatigue. Mean power of the EEG alpha bands for the Fz-Pz channels were found to be higher on the high-load task compared to low-load task, while for the O1-O2 channels, they were higher on the low-load task than on the high-load task. These results indicated that the load levels effect the upper limb muscle and brain activities. The high-load task will increase muscle activities on the right brachioradialis and the left upper tapezius muscles, and will increase the awareness and motivation of the subjects. Whilst the low-load task can generate drowsiness earlier. It signified that the longer the time and the more heavy of the task, the subjects will be more fatigue physically and mentally.

  8. The stem factor challenge

    International Nuclear Information System (INIS)

    Russell, M.J.; Steele, R. Jr.; DeWall, K.G.; Watkins, J.C.; Bramwell, D.

    1994-01-01

    One of the most important challenges that still needs to be met in the effort to understand the operation of motor-operated, rising-stem valves is the ability to determine stem factor throughout the valve's load range. The stem factor represents the conversion of operator torque to stem thrust. Determining the stem factor is important because some motor-operated valves (MOVs) cannot be tested in the plant at design basis conditions. The ability of these valves to perform their design basis function (typically, to operate against specified flow and pressure loads) must be ensured by analytical methods or by extrapolating from the results of tests conducted at lower loads. Because the stem factor tends to vary in response to friction and lubrication phenomena that occur during loading and wedging, analytical methods and extrapolation methods have been difficult to develop and implement. Early investigations into variability in the stem factor tended to look only at the tip of the iceberg; they focused on what was happening at torque switch trip, which usually occurs at full wedging. In most stems, the stem factor is better (lower) in the wedging transient than before wedging, so working with torque switch trip data alone led many early researchers to false conclusions about the relationship between stem factor and load. However, research at the Idaho National Engineering Laboratory (INEL) has taken a closer look at what happens during the running portion of the closing stroke along with the wedging portion. This shift in focus is important, because functional failure of a valve typically consists of a failure to isolate flow, not a failure to achieve full wedging. Thus, the stem factor that must be determined for a valve's design basis closing requirements is the one that corresponds with the running load before wedging

  9. Mechanics of arterial subfailure with increasing loading rate.

    Science.gov (United States)

    Stemper, Brian D; Yoganandan, Narayan; Pintar, Frank A

    2007-01-01

    Arterial subfailure leads to delayed symptomatology and high morbidity and mortality rates, particularly for the thoracic aorta and carotid arteries. Although arterial injuries occur during high-velocity automotive collisions, previous studies of arterial subfailure focused on quasi-static loading. This investigation subjected aortic segments to increasing loading rates to quantify effects on elastic, subfailure, and ultimate vessel mechanics. Sixty-two specimens were axially distracted, and 92% demonstrated subfailure before ultimate failure. With increasing loading rate, stress at initial subfailure and ultimate failure significantly increased, and strain at initial subfailure and ultimate failure significantly decreased. Present results indicate increased susceptibility for arterial subfailure and/or dissection under higher-rate extension. According to the present results, automotive occupants are at greater risk of arterial injury under higher velocity impacts due to greater body segment motions in addition to decreased strain tolerance to subfailure and catastrophic failure.

  10. Encouraging Factors for Invest in Higher Education in the Private Sector in Iran

    Directory of Open Access Journals (Sweden)

    Shahram Yazdani

    2017-08-01

    Full Text Available Higher education which has the main role in the training of skilled human resource can also be considered as the foundation of wealth creation in the country. The quantitative and qualitative expansion of higher education is inevitable. The facilities and the government budget are not responsive for the need, due to the increasing demand of young people for entering higher education in Iran. Therefore, developing and equipping universities and unpublicized and private higher education institutions have received considerable attention and have grown substantially. We aimed to evaluate educational experts regarding encouraging factors of the private sections for more participating in financing of higher education centers and institutions in Iran. Qualitative content analysis method has been used.The participants were selected using purposive sampling. The professors were in positions of policymaking and managing and had opinions on the challenges of universities financing. Data collection was conducted with semi-structured interview in 2016 and all ethical considerations associated with qualitative research were respected. The main concepts obtained from the interview were reported in the three main themes and their sub-classes. We have found that with the authorities given to universitiesby law, and preparing the transition from the based solely on government resources to the private section is provided by taking the appropriate decisions of managers to attract investors Universities can benefit from promoting different mechanisms to attract private financing in the higher education section. Solutions also were presented in this way. The idea of educational investment not only can promote the community investments towards higher education, but also has been the promotion of knowledge-based business in the community and promotes entrepreneurship and knowledge-based economy.Keywords: HIGHER EDUCATION, EDUCATIONAL INVESTMENT, KNOWLEDGE-BASED ECONOMY

  11. A gravity loading countermeasure skinsuit

    Science.gov (United States)

    Waldie, James M.; Newman, Dava J.

    2011-04-01

    Despite the use of several countermeasures, significant physiological deconditioning still occurs during long duration spaceflight. Bone loss - primarily due to the absence of loading in microgravity - is perhaps the greatest challenge to resolve. This paper describes a conceptual Gravity Loading Countermeasure Skinsuit (GLCS) that induces loading on the body to mimic standing and - when integrated with other countermeasures - exercising on Earth. Comfort, mobility and other operational issues were explored during a pilot study carried out in parabolic flight for prototype suits worn by three subjects. Compared to the 1- or 2-stage Russian Pingvin Suits, the elastic mesh of the GLCS can create a loading regime that gradually increases in hundreds of stages from the shoulders to the feet, thereby reproducing the weight-bearing regime normally imparted by gravity with much higher resolution. Modelling shows that the skinsuit requires less than 10 mmHg (1.3 kPa) of compression for three subjects of varied gender, height and mass. Negligible mobility restriction and excellent comfort properties were found during the parabolic flights, which suggests that crewmembers should be able to work normally, exercise or sleep while wearing the suit. The suit may also serve as a practical 1 g harness for exercise countermeasures and vibration applications to improve dynamic loading.

  12. Higher-twist effects in the B → π transition form factor from QCD light-cone sum rules

    Energy Technology Data Exchange (ETDEWEB)

    Khodjamirian, Alexander; Rusov, Aleksey [Universitaet Siegen (Germany). Fakultaet IV, Department Physik, Theoretische Physik 1 Walter-Flex-Strasse 3 57068 Siegen

    2016-07-01

    I report on the progress in calculating new higher-twist corrections to the QCD light-cone sum rule for the B → π transition form factor. First, the expansion of the massive heavy-quark propagator in the external gluonic field near the light-cone was extended to include new terms containing the gluon-field strength derivatives. The resulting analytical expressions for the twist-5 and twist-6 contributions to the correlation function were obtained in a factorized approximation, expressed via the product of the quark-condensate density and the lower-twist pion distribution amplitudes. The numerical analysis of new higher-twist effects is in progress.

  13. Cementitious Stabilization of Mixed Wastes with High Salt Loadings

    International Nuclear Information System (INIS)

    Spence, R.D.; Burgess, M.W.; Fedorov, V.V.; Downing, D.J.

    1999-01-01

    Salt loadings approaching 50 wt % were tolerated in cementitious waste forms that still met leach and strength criteria, addressing a Technology Deficiency of low salt loadings previously identified by the Mixed Waste Focus Area. A statistical design quantified the effect of different stabilizing ingredients and salt loading on performance at lower loadings, allowing selection of the more effective ingredients for studying the higher salt loadings. In general, the final waste form needed to consist of 25 wt % of the dry stabilizing ingredients to meet the criteria used and 25 wt % water to form a workable paste, leaving 50 wt % for waste solids. The salt loading depends on the salt content of the waste solids but could be as high as 50 wt % if all the waste solids are salt

  14. MA-core loaded untuned RF compression cavity for HIRFL-CSR

    International Nuclear Information System (INIS)

    Mei Lirong; Xu Zhe; Yuan Youjin; Jin Peng; Bian Zhibin; Zhao Hongwei; Xia Jiawen

    2012-01-01

    To meet the requirements of high energy density physics and plasma physics research at HIRFL-CSR the goal of achieving a higher accelerating gap voltage was proposed. Therefore, a magnetic alloy (MA)-core loaded radio frequency (RF) cavity that can provide a higher accelerating gap voltage compared to standard ferrite loaded cavities has been studied at IMP. In order to select the proper magnetic alloy material to load the RF compression cavity, measurements of four different kinds of sample MA-cores have been carried out. By testing the small cores, the core composition was selected to obtain the desired performance. According to the theoretical calculation and simulation, which show reasonable consistency for the MA-core loaded cavity, the desired performance can be achieved. Finally about 1000 kW power will be needed to meet the requirements of 50 kV accelerating gap voltage by calculation.

  15. Critical traffic loading for the design of prestressed concrete bridge

    International Nuclear Information System (INIS)

    Hassan, M.I.U.

    2009-01-01

    A study has been carried out to determine critical traffic loadings for the design of bridge superstructures. The prestressed concrete girder bridge already constructed in Lahore is selected for the analysis as an example. Standard traffic loadings according to AASHTO (American Association of State Highway and Transportation Officials) and Pakistan Highway Standards are used for this purpose. These include (1) HL-93 Truck, (2) Lane and (3) Tandem Loadings in addition to (4) Military tank loading, (5) Class-A, (6) Class-B and (7) Class-AA loading, (8) NLC (National Logistic Cell) and (9) Volvo truck loadings. Bridge superstructure including transom beam is analyzed Using ASD and LRFD (Load and Resistance Factor Design) provisions of AASHTO specifications. For the analysis, two longer and shorter spans are selected. This includes the analysis of bridge deck; interior and exterior girder; a typical transom beam and a pier. Dead and live loading determination is carried out using both computer aided and manual calculations. Evaluation of traffic loadings is done for all the bridge components to find out the critical loading. HL-93 loading comes out to be the most critical loading and where this loading is not critical in case of bridge decks; a factor of 1.15 is introduced to make it equivalent with HL-93 -Ioading. SAP-2000 (Structural Engineering Services of Pakistan) and MS-Excel is employed for analysis of bridge superstructure subjected to this loading. Internal forces are obtained for the structural elements of the bridge for all traffic loadings mentioned. It is concluded that HL-93 loading can be used for the design of prestressed concrete girder bridge. Bridge design authorities like NHA (National Highway Authority) and different cities development authorities are using different standard traffic loadings. A number of suggestions are made from the results of the research work related to traffic loadings and method of design. These recommendations may be

  16. Expected load spectra of prototype Francis turbines in low-load operation using numerical simulations and site measurements

    Science.gov (United States)

    Eichhorn, M.; Taruffi, A.; Bauer, C.

    2017-04-01

    The operators of hydropower plants are forced to extend the existing operating ranges of their hydraulic machines to remain competitive on the energy market due to the rising amount of wind and solar power. Faster response times and a higher flexibility towards part- and low-load conditions enable a better electric grid control and assure therefore an economic operation of the power plant. The occurring disadvantage is a higher dynamic excitation of affected machine components, especially Francis turbine runners, due to pressure pulsations induced by unsteady flow phenomena (e.g. draft tube vortex ropes). Therefore, fatigue analysis becomes more important even in the design phase of the hydraulic machines to evaluate the static and dynamic load in different operating conditions and to reduce maintenance costs. An approach including a one-way coupled fluid-structure interaction has been already developed using unsteady CFD simulations and transient FEM computations. This is now applied on two Francis turbines with different specific speeds and power ranges, to obtain the load spectra of both machines. The results are compared to strain gauge measurements on the according Francis turbines to validate the overall procedure.

  17. Dynamic Load Balancing of Parallel Monte Carlo Transport Calculations

    International Nuclear Information System (INIS)

    O'Brien, M; Taylor, J; Procassini, R

    2004-01-01

    The performance of parallel Monte Carlo transport calculations which use both spatial and particle parallelism is increased by dynamically assigning processors to the most worked domains. Since the particle work load varies over the course of the simulation, this algorithm determines each cycle if dynamic load balancing would speed up the calculation. If load balancing is required, a small number of particle communications are initiated in order to achieve load balance. This method has decreased the parallel run time by more than a factor of three for certain criticality calculations

  18. Effect of Load Duration on Timber Structures in Denmark

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Stang, Birgitte Friis Dela; Svensson, Staffan

    2003-01-01

    . The parameters in these models are fitted by the Maximum Likelihood Method using data relevant for Danish structural timber and the statistical uncertainty is quantified. The reliability is evaluated using representative shortand long-term limit states, and the load duration factor kmod is estimated using......Load duration effects are estimated on basis of simulation of realizations of wind, snow and imposed loads in accordance with the load models in the Danish structural codes. Three damage accumulation models are considered, namely Gerhards model, Barret & Foschi's model and Foschi & Yao's model...

  19. Analysis of an AC-DC full-controlled converter supplying two DC-Series-Motor loads

    International Nuclear Information System (INIS)

    Al-Hindawi, Mohammed M.; Al-Turki, Yusuf A.; Al-Subaie, Obaid T.

    2000-01-01

    Phase-controlled converters are widely used because these converters are simple, less expensive, reliable, and do not require any communication circuit. Series motors are extensively used in many applications that require both high starting torque and essentially constant horse power. This paper is concerned with the detailed study of the performance characteristics of an AC-DC full-controlled converter supplying two DC-series-motor loads. The converter loads combination is simulated on a digital computer. Different modes of operation (continuous and discontinuous converter currents) are considered. The critical firing angle at which the mode of operation changes from one mode to another is deduced. The performance characteristics such input power factor, supply current distortion factor, supply current fundamental power factor, torque speed, and motor current ripple factor have been derived and studied for both constant firing angle and constant load factor have been derived and studied for both constant firing angle and constant load power of one motor. Waveforms for each load current and converter current are investigated for different modes of operation. (author)

  20. Benzimidazole-loaded Halloysite Nanotube as a Smart Coating Application

    Directory of Open Access Journals (Sweden)

    Khairina Azmi Zahidah

    2017-09-01

    Full Text Available Smart coating has been developed for the corrosion control of surfaces exposed to corrosive environment. An important step in development of a smart coating is the successful impregnation of corrosion inhibitor into the nanocontainer as a coating pigment. In this study, halloysite was used as nanocontainer to encapsulate benzimidazole as corrosion inhibitor by vacuum method. FESEM, TEM, FTIR and TGA characterization techniques were used to confirm the loading of halloysite with benzimidazole. FESEM results indicated differences between the morphology of the unloaded-halloysite and benzimidazole loaded-halloysite. TEM results confirmed that benzimidazole molecules are loaded into halloysite. FTIR result revealed there are differences in the absorbance characteristic of peaks between peak number 1000-4000 cm-1 for loaded and unloaded samples. It is seen that the absorbance in the loaded-halloysite is higher than unloaded-halloysite, which confirms quantity/specific functional group of molecules. TGA result showed the temperature of degradation of benzimidazole-loaded HNT was higher than pure HNT. EIS was conducted to examine the protection characteristic of the developed smart coating. From EIS results, of 1, 3, and 6 days of experimental duration, it is seen that the value of coating impedance (Z’ after exposure to 3.5% NaCl environment is very height, 2.460E+07 Ω, which confirm a very good anti corrosion protection characteristic for the developed smart coating. 

  1. Monitoring organic loading to swimming pools by fluorescence excitation–emission matrix with parallel factor analysis (PARAFAC)

    DEFF Research Database (Denmark)

    Seredynska-Sobecka, Bozena; Stedmon, Colin; Boe-Hansen, Rasmus

    2011-01-01

    Fluorescence Excitation–Emission Matrix spectroscopy combined with parallel factor analysis was employed to monitor water quality and organic contamination in swimming pools. The fluorescence signal of the swimming pool organic matter was low but increased slightly through the day. The analysis...... revealed that the organic matter fluorescence was characterised by five different components, one of which was unique to swimming pool organic matter and one which was specific to organic contamination. The latter component had emission peaks at 420nm and was found to be a sensitive indicator of organic...... loading in swimming pool water. The fluorescence at 420nm gradually increased during opening hours and represented material accumulating through the day....

  2. HPV-16 viral load in oropharyngeal squamous cell carcinoma using digital PCR.

    Science.gov (United States)

    Antonsson, Annika; Knight, Lani; Panizza, Benedict J; Porceddu, Sandro V; Emmett, Sarah; Whiteman, David C

    2018-05-09

    We did not identify any strong associations between HPV-16 viral load and any of the clinical or lifestyle factors. The epidemiology of oropharyngeal SCC is changing, with an increasing proportion of HPV-positive cases seen in the last decade. It is known that a high viral load is linked to the development of cervical cancer, the relation between viral load and oropharyngeal SCC is less clear. We sought to determine HPV-16 viral load in HPV-positive oropharyngeal SCCs using highly sensitive digital PCR and to identify clinical and lifestyle factors associated with viral load. We analysed 45 HPV-16 positive oropharyngeal SCCs diagnosed between 2013 and 2015. All patients completed a lifestyle questionnaire and clinical data were extracted from medical charts. Viral load was determined using digital PCR assays for HPV-L1 and RNAseP. We found large variations in HPV-16 viral load from 1 to 930 copies per cell (median 34 copies per cell).

  3. Stress intensity factors of eccentric cracks in bi-materials plate under mode I loading

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, A. E. [Faculty of Mechanical and Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, 86400 Batu Pahat, Johor (Malaysia)

    2015-05-15

    Bi-material plates were generally used to joint electronic devices or mechanical components requiring dissimilar materials to be attached. During services, mechanical failure can be occurred due to the formation of cracks at the interfacial joint or away from the centre. Generally, linear elastic fracture mechanics approach is used to characterize these cracks based on stress intensity factors (SIF). Based on the literature survey, the SIFs for the central cracks were easily available. However, the SIFs for eccentric cracks were difficult to obtain. Therefore, this paper presented the SIFs for eccentric cracks subjected to mode I tension loading. Three important parameters were used such as relative crack depth, a/L, relative offset distance, b/L and elastic mismatch, E{sub 1}/E{sub 2} or α. It was found that such parameters significantly affected the characteristic of SIFs and it was depend on the location of cracks.

  4. Enhancement of urban heat load through social inequalities on an example of a fictional city King's Landing

    Science.gov (United States)

    Žuvela-Aloise, M.

    2017-03-01

    The numerical model MUKLIMO_3 is used to simulate the urban climate of an imaginary city as an illustrative example to demonstrate that the residential areas with deprived socio-economic conditions can exhibit an enhanced heat load at night, and thus more disadvantageous environmental conditions, compared with the areas of higher socio-economic status. The urban climate modelling simulations differentiate between orographic, natural landscape, building and social effects, where social differences are introduced by selection of location, building type and amount of vegetation. The model results show that the increase of heat load can be found in the areas inhabited by the poor population as a combined effect of natural and anthropogenic factors. The unfavourable location in the city and the building type, consisting of high density, low housing with high fraction of pavement and small amount of vegetation contribute to the formation of excessive heat load. This abstract example shows that the enhancement of urban heat load can be linked to the concept of a socially stratified city and is independent of the historical development of any specific city.

  5. Hypericin-loaded nanoparticles for the photodynamic treatment of ovarian cancer.

    Science.gov (United States)

    Zeisser-Labouèbe, Magali; Lange, Norbert; Gurny, Robert; Delie, Florence

    2006-12-01

    A photodynamic approach has been suggested to improve diagnosis and therapy of ovarian cancer. As Hypericin (Hy), a natural photosensitizer (PS) extracted from Hypericum perforatum, has been shown to be efficient in vitro and in vivo for the detection or treatment of other cancers, Hy could also be a potent tool for the treatment and detection of ovarian cancer. Due to its hydrophobicity, systemic administration of Hy is problematic. Thus, polymeric nanoparticles (NPs) of polylactic acid (PLA) or polylactic-co-glycolic acid (PLGA) were used as a drug delivery system. Hy-loaded NPs were produced with the following characteristics: (i) size in the 200-300 nm range, (ii) negative zeta potential, (iii) low residual PVAL and (iv) drug loading from 0.03 to 0.15% (w/w). Their in vitro photoactivity was investigated on the NuTu-19 ovarian cancer cell model derived from Fischer 344 rats and compared to free drug. Hy-loaded PLA NPs exhibited a higher photoactivity than free drug. Increasing light dose or incubation time with cells induced an enhanced activity of Hy-loaded PLA NPs. Increased NP drug loading had a negative effect on their photoactivity on NuTu-19 cells: at the same Hy concentration, the higher was the drug loading, the lower was the phototoxic effect. The influence of NP drug loading on the Hy release from NPs was also investigated.

  6. Development of Engine Loads Methodology, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR seeks to improve the definition of design loads for rocket engine components such that higher performing, lighter weight engines can be developed more...

  7. Trunk muscle activation in the back and hack squat at the same relative loads.

    Science.gov (United States)

    Clark, David R; Lambert, Michael I; Hunter, Angus M

    2017-07-12

    The hack squat (HS) is likely to produce a greater 1 repetition maximum (1RM) compared to the back squat (BS). This can be attributed to the support of the trunk during the HS compared to no support during BS. This support however, may compromise trunk muscle activation (TMA), therefore producing different training adaptations. Accordingly, the purpose of this study was to compare 1RM in BS and HS and TMA at 4 relative loads, 65, 75, 85 and 95% of maximal system mass. Ten males completed 3 test sessions:1) BS and HS 1RM, 2) HS & BS neuromuscular test familiarization, and, 3) Neuromuscular test for 3 reps at 4 loads for BS and HS. BS TMA was significantly greater (p<0.05) than HS for all muscles and phases except rectus abdominus in concentric phase. TMA increased (p<0.05) with load in all muscles for both exercises and phases apart from lumbar sacral erector spinae in HS eccentric phase. Mean HS 1RM and submaximal loads were significantly (p<0.0001) higher than the equivalent BS loads. Duration of the eccentric phase was higher (p<0.01) in HS than BS but not different in concentric phase. Duration increased significantly (p<0.01) with load in both exercises and both phases. Despite higher absolute tests loads in HS, TMA was higher in BS. TMA is sensitive to load in both exercises. BS is more effective than HS in activating the muscles of the trunk and therefore arguably more effective in developing trunk strength and stability for dynamic athletic performance.

  8. Dynamic modeling and analysis of load sharing characteristics of wind turbine gearbox

    Directory of Open Access Journals (Sweden)

    Pengxing Yi

    2015-03-01

    Full Text Available A coupled dynamic model, which contains helical gears-shafts-bearings for a wind turbine gearbox transmission system, was built considering nonlinear factors of the time-varying mesh stiffness, the external varying load, and the dynamic transmission error at first. The model is confirmed to be right after comparing the theoretical data with the experimental load sharing values, and also it is found that the static load sharing is conservative to evaluate the non-equilibrium effect of a planetary gear system. Besides, the analyzing results of the influence of average error and amplitude error on the load sharing show that the load sharing could be decreased if the error goes up a little. Then, by means of treating the static tracing point as the dynamic initial values, we analyzed the initial position’s influence on the load sharing of transmission system to provide a theoretical basis of load sharing control. Furthermore, we explored the influence of high-speed shaft position angle on the load sharing and the dynamic load factor of gears fixed on the parallel shafts. The results provide useful theoretical guidelines for the design of parallel shaft gear system in the wind turbines.

  9. Training Load, Immune Status, and Clinical Outcomes in Young Athletes: A Controlled, Prospective, Longitudinal Study

    Directory of Open Access Journals (Sweden)

    Katharina Blume

    2018-03-01

    Full Text Available Introduction: Beside positive effects on athlete's health, competitive sport can be linked with an increased risk of illness and injury. Because of high relative increases in training, additional physical and psychological strains, and an earlier specialization and professionalization, adolescent athletes needs an increased attention. Training can alter the immune system by inducing a temporary immunosuppression, finally developing infection symptoms. Previous studies identified Epstein Barr Virus (EBV as potential indicator for the immune status. In addition to the identification of triggering risk factors for recurrent infections, the aim was to determine the interaction between training load, stress sense, immunological parameters, and clinical symptoms.Methods: A controlled, prospective, longitudinal study on young athletes (n = 274, mean age: 13.8 ± 1.5 yrs was conducted between 2010 and 2014. Also 285 controls (students, who did not perform competitive sports, mean age: 14.5 ± 1.9 yrs were recruited. Athletes were examined 3 times each year to determine the effects of stress factors (training load: training hours per week [Th/w] on selected outcome parameters (clinical [susceptibility to infection, WURSS-21: 21-item Wisconsin Upper Respiratory Symptom Survey], immunological, psychological end points. As part of each visit, EBV serostatus and EBV-specific IgG tiers were studied longitudinally as potential immune markers.Results: Athletes (A trained 14.9 ± 5.6 h weekly. Controls (C showed no lower stress levels compared to athletes (p = 0.387. Twelve percent of athletes reported recurrent infections (C: 8.5%, p = 0.153, the presence of an upper respiratory tract infection (URTI was achieved in 30.7%. EBV seroprevalence of athletes was 60.3% (C: 56.6%, p = 0.339. Mean EBV-specific IgG titer of athletes was 166 ± 115 U/ml (C: 137 ± 112 U/ml, p = 0.030. With increasing Th/w, higher stress levels were observed (p < 0.001. Analyzes of WURSS

  10. Enzyme loading dependence of cellulose hydrolysis of sugarcane bagasse

    Directory of Open Access Journals (Sweden)

    Carlos Martín

    2012-01-01

    Full Text Available The enzymatic hydrolysis of steam-pretreated sugarcane bagasse, either delignified or non-delignified, was studied as a function of enzyme loading. Hydrolysis experiments were carried out using five enzyme loadings (2.5 to 20 FPU/g cellulose and the concentration of solids was 2% for both materials. Alkaline delignification improved cellulose hydrolysis by increasing surface area. For both materials, glucose concentrations increased with enzyme loading. On the other hand, enzyme loadings higher than 15 FPU/g did not result in any increase in the initial rate, since the excess of enzyme adsorbed onto the substrate restricted the diffusion process through the structure.

  11. Friction and anchorage loading revisited.

    Science.gov (United States)

    Dholakia, Kartik D

    2012-01-01

    Contemporary concepts of sliding mechanics explain that friction is inevitable. To overcome this frictional resistance, excess force is required to retract the tooth along the archwire (ie, individual retraction of canines, en masse retraction of anterior teeth), in addition to the amount of force required for tooth movement. The anterior tooth retraction force, in addition to excess force (to overcome friction), produces reciprocal protraction force on molars, thereby leading to increased anchorage loading. However, this traditional concept was challenged in recent literature, which was based on the finite element model, but did not bear correlation to the clinical scenario. This article will reinforce the fact that clinically, friction increases anchorage loading in all three planes of space, considering the fact that tooth movement is a quasistatic process rather than a purely continuous or static one, and that conventional ways of determining the effects of static or dynamic friction on anchorage load cannot be applied to clinical situations (which consist of anatomical resistance units and a complex muscular force system). The article does not aim to quantify friction and its effect on the amount of anchorage load. Rather, a new perspective regarding the role of various additional factors (which is not explained by contemporary concept) that may influence friction and anchorage loading is provided..

  12. Harmonics mitigation on industrial loads using series and parallel ...

    African Journals Online (AJOL)

    Most industrial loads are inductive in nature and therefore absorb Volts Ampere Reactance (VARs) leading to lagging power factor. Some inductive loads also produce current and voltage signals with frequencies in integer multiples of the 50 or 60 Hz fundamental frequencies called harmonics. Harmonics in power system ...

  13. Load Loss Performance of an Autonomous Self-Excited Induction ...

    African Journals Online (AJOL)

    This paper presents a dynamic analysis of an autonomous Self-Excited Induction Generator (SEIG) showing dynamic loss of load performance. In stand-alone operation of the SEIG, especially when supplying a low power utility, an interesting performance of the SEIG observed for various power factor loads can be ...

  14. Performance of a 2-megawatt high voltage test load

    International Nuclear Information System (INIS)

    Horan, D.; Kustom, R.; Ferguson, M.

    1995-01-01

    A high-power, water-cooled resistive load which simulates the electrical load characteristics of a high-power klystron, capable of 2 megawatts dissipation at 95 kV DC, was built and installed at the Advanced Photon Source for use in load-testing high voltage power supplies. During this testing, the test load has logged approximately 35 hours of operation at power levels in excess of one mezawatt. Slight variations in the resistance of the load during operation indicate that leakage currents in the cooling water may be a significant factor affecting the performance of the load. Sufficient performance data have been collected to indicate that leakage current through the deionized (DI) water coolant shunts roughly 15 percent of the full-load current around the load resistor elements. The leakage current could cause deterioration of internal components of the load. The load pressure vessel was disassembled and inspected internally for any signs of significant wear and distress. Results of this inspection and possible modifications for improved performance will be discussed

  15. Measuring cognitive load: mixed results from a handover simulation for medical students.

    Science.gov (United States)

    Young, John Q; Irby, David M; Barilla-LaBarca, Maria-Louise; Ten Cate, Olle; O'Sullivan, Patricia S

    2016-02-01

    The application of cognitive load theory to workplace-based activities such as patient handovers is hindered by the absence of a measure of the different load types. This exploratory study tests a method for measuring cognitive load during handovers. The authors developed the Cognitive Load Inventory for Handoffs (CLI4H) with items for intrinsic, extraneous, and germane load. Medical students completed the measure after participating in a simulated handover. Exploratory factor and correlation analyses were performed to collect evidence for validity. Results yielded a two-factor solution for intrinsic and germane load that explained 50 % of the variance. The extraneous load items performed poorly and were removed from the model. The score for intrinsic load correlated with the Paas Cognitive Load scale (r = 0.31, p = 0.004) and was lower for students with more prior handover training (p = 0.036). Intrinsic load did not, however, correlate with performance. Germane load did not correlate with the Paas Cognitive Load scale but did correlate as expected with performance (r = 0.30, p = 0.005) and was lower for those students with more prior handover training (p = 0.03). The CLI4H yielded mixed results with some evidence for validity of the score from the intrinsic load items. The extraneous load items performed poorly and the use of only a single item for germane load limits conclusions. The instrument requires further development and testing. Study results and limitations provide guidance to future efforts to measure cognitive load during workplace-based activities, such as handovers.

  16. Concentration: The Neural Underpinnings of How Cognitive Load Shields Against Distraction.

    Science.gov (United States)

    Sörqvist, Patrik; Dahlström, Örjan; Karlsson, Thomas; Rönnberg, Jerker

    2016-01-01

    Whether cognitive load-and other aspects of task difficulty-increases or decreases distractibility is subject of much debate in contemporary psychology. One camp argues that cognitive load usurps executive resources, which otherwise could be used for attentional control, and therefore cognitive load increases distraction. The other camp argues that cognitive load demands high levels of concentration (focal-task engagement), which suppresses peripheral processing and therefore decreases distraction. In this article, we employed an functional magnetic resonance imaging (fMRI) protocol to explore whether higher cognitive load in a visually-presented task suppresses task-irrelevant auditory processing in cortical and subcortical areas. The results show that selectively attending to an auditory stimulus facilitates its neural processing in the auditory cortex, and switching the locus-of-attention to the visual modality decreases the neural response in the auditory cortex. When the cognitive load of the task presented in the visual modality increases, the neural response to the auditory stimulus is further suppressed, along with increased activity in networks related to effortful attention. Taken together, the results suggest that higher cognitive load decreases peripheral processing of task-irrelevant information-which decreases distractibility-as a side effect of the increased activity in a focused-attention network.

  17. Blood Pressure and Arterial Load After Transcatheter Aortic Valve Replacement for Aortic Stenosis.

    Science.gov (United States)

    Lindman, Brian R; Otto, Catherine M; Douglas, Pamela S; Hahn, Rebecca T; Elmariah, Sammy; Weissman, Neil J; Stewart, William J; Ayele, Girma M; Zhang, Feifan; Zajarias, Alan; Maniar, Hersh S; Jilaihawi, Hasan; Blackstone, Eugene; Chinnakondepalli, Khaja M; Tuzcu, E Murat; Leon, Martin B; Pibarot, Philippe

    2017-07-01

    After aortic valve replacement, left ventricular afterload is often characterized by the residual valve obstruction. Our objective was to determine whether higher systemic arterial afterload-as reflected in blood pressure, pulsatile and resistive load-is associated with adverse clinical outcomes after transcatheter aortic valve replacement (TAVR). Total, pulsatile, and resistive arterial load were measured in 2141 patients with severe aortic stenosis treated with TAVR in the PARTNER I trial (Placement of Aortic Transcatheter Valve) who had systolic blood pressure (SBP) and an echocardiogram obtained 30 days after TAVR. The primary end point was 30-day to 1-year all-cause mortality. Lower SBP at 30 days after TAVR was associated with higher mortality (20.0% for SBP 100-129 mm Hg versus 12.0% for SBP 130-170 mm Hg; P <0.001). This association remained significant after adjustment, was consistent across subgroups, and confirmed in sensitivity analyses. In adjusted models that included SBP, higher total and pulsatile arterial load were associated with increased mortality ( P <0.001 for all), but resistive load was not. Patients with low 30-day SBP and high pulsatile load had a 3-fold higher mortality than those with high 30-day SBP and low pulsatile load (26.1% versus 8.1%; hazard ratio, 3.62; 95% confidence interval, 2.36-5.55). Even after relief of valve obstruction in patients with aortic stenosis, there is an independent association between post-TAVR blood pressure, systemic arterial load, and mortality. Blood pressure goals in patients with a history of aortic stenosis may need to be redefined. Increased pulsatile arterial load, rather than blood pressure, may be a target for adjunctive medical therapy to improve outcomes after TAVR. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00530894. © 2017 American Heart Association, Inc.

  18. Thrust and torque characteristics based on a new cutter-head load model

    Science.gov (United States)

    Liu, Jianqin; Ren, Jiabao; Guo, Wei

    2015-07-01

    Full face rock tunnel boring machine(TBM) has been widely used in hard rock tunnels, however, there are few published theory about cutter-head design, and the design criteria of cutter-head under complex geological is not clear yet. To deal with the complex relationship among geological parameters, cutter parameters, and operating parameters during tunneling processes, a cutter-head load model is established by using CSM(Colorado school of mines) prediction model. Force distribution on cutter-head under a certain geology is calculated with the new established load model, and result shows that inner cutters bear more force than outer cutters, combining with disc cutters abrasion; a general principle of disc cutters' layout design is proposed. Within the model, the relationship among rock uniaxial compressive strength(UCS), penetration and thrust on cutter-head are analyzed, and the results shows that with increasing penetration, cutter thrust increases, but the growth rate slows and higher penetration makes lower special energy(SE). Finally, a fitting mathematical model of ZT(ratio of cutter-head torque and thrust) and penetration is established, and verified by TB880E, which can be used to direct how to set thrust and torque on cutter-head. When penetration is small, the cutter-head thrust is the main limiting factor in tunneling; when the penetration is large, cutter-head torque is the major limiting factor in tunneling. Based on the new cutter-head load model, thrust and torque characteristics of TBM further are researched and a new way for cutter-head layout design and TBM tunneling operations is proposed.

  19. Assessment on Ultimate Load of Cold-formed Steel Channel (CFSC Stub Column

    Directory of Open Access Journals (Sweden)

    Mohd Sani Mohd Syahrul Hisyam

    2015-01-01

    Full Text Available Cold-formed steel is used as the non-structural and structural material in civil engineering work and building. Cold-formed steel channel is selected and cut into 100 mm, 200 mm, 300 mm, 400 mm and 500 mm. The slenderness ratio is calculated and noted as a stub or short column because below 40. The column is tested by using Universal Testing Machine to determine the ultimate load of the stub column. Besides, the CFSC is determined the material properties of CFSC for checking it’s the originality of steel based material. The experimental data are tested and compared with the Direct Strength Method (DSM. It showed that the CFSC1 with a height of 100 mm is reported to have a higher value of ultimate load when compared with other samples. When the height of the stub column increased, the ultimate load of the sample is decreased. Then, the CFSC1 also showed a higher in initial stiffness when compared with other samples. All samples are shown having a higher data in ultimate load when compared with the Direct Strength Method prediction. The ultimate load of experimental and DSM all gave a ratio below 1.03. Finally, all samples can further recommend determining the relation between the ultimate loads with variations of height of the column.

  20. Introduction effect of a load levelling system in an electric power system with a photovoltaic and wind system; Taiyoko/furyoku hatsuden wo donyu shita denryoku keito ni okeru fuka heijunka shisutemu no donyu koka

    Energy Technology Data Exchange (ETDEWEB)

    Kenmoku, Y.; Sakakibara, T. [Toyohashi University of Technology, Aichi (Japan); Nakagawa, S. [Maizuru College of Technology, Kyoto (Japan); Kawamoto, T. [Shizuoka University, Shizuoka (Japan)

    1998-12-05

    Introduction effect of load levelling system by a battery in an electric power system by a battery in an electric power system with a PV and wind system is investigated. Charge and discharge power of the battery are determined from a load curve and every hour data of PV and wind output. Annual cost of the power system is calculated from the generating power and the capacity of each source via the installed utility capacity and the capacity factor. It is found that (1) the battery system reduces the maximum demand and improves the load factor, (2) the cost effect of the battery system when introducing the PV system is higher than that when introducing the wind system. (author)

  1. Comparison of Deterministic and Probabilistic Radial Distribution Systems Load Flow

    Science.gov (United States)

    Gupta, Atma Ram; Kumar, Ashwani

    2017-12-01

    Distribution system network today is facing the challenge of meeting increased load demands from the industrial, commercial and residential sectors. The pattern of load is highly dependent on consumer behavior and temporal factors such as season of the year, day of the week or time of the day. For deterministic radial distribution load flow studies load is taken as constant. But, load varies continually with a high degree of uncertainty. So, there is a need to model probable realistic load. Monte-Carlo Simulation is used to model the probable realistic load by generating random values of active and reactive power load from the mean and standard deviation of the load and for solving a Deterministic Radial Load Flow with these values. The probabilistic solution is reconstructed from deterministic data obtained for each simulation. The main contribution of the work is: Finding impact of probable realistic ZIP load modeling on balanced radial distribution load flow. Finding impact of probable realistic ZIP load modeling on unbalanced radial distribution load flow. Compare the voltage profile and losses with probable realistic ZIP load modeling for balanced and unbalanced radial distribution load flow.

  2. Effect of combined loading on pipe flaw evaluation criteria

    International Nuclear Information System (INIS)

    Miura, Naoki; Chung Yeonki

    1999-01-01

    Considering a rational maintenance rule of Light Water Reactor piping, reliable flaw evaluation criteria are essential to determine how a detected flaw is detrimental to continuous plant operation. Ductile fracture is one of the dominant failure modes to be considered for carbon steel piping, and can be analyzed by the elastic-plastic fracture mechanics. Currently the analytical results are provided as flaw evaluation criteria using load correction factors such like the Z-factor in ASME Code Section 6. The present correction factors were conventionally determined taken a conservatism and a simplicity into account, however, the effect of internal pressure which would be an important factor under an actual plant condition was not adequately considered. Recently, a J-estimation scheme, 'LBB.ENGC' for ductile fracture analysis of circumferentially through-wall-cracked pipes subjected to combined loading was newly developed to have a better prediction with more realistic manner. This method is explicitly incorporated the contribution of both bending and tension due to internal pressure by means of the scheme compatible with an arbitrary combined loading history. In this paper, the effect of internal pressure on the flaw evaluation criteria was investigated using the new J-estimation scheme. A correction factor based on the new J-estimation scheme was compared with the present correction factors, and the predictability of the current flaw evaluation criteria was quantitatively evaluated in consideration of internal pressure. (author)

  3. High and increasing Oxa-51 DNA load predict mortality in Acinetobacter baumannii bacteremia: implication for pathogenesis and evaluation of therapy.

    Directory of Open Access Journals (Sweden)

    Yu-Chung Chuang

    Full Text Available BACKGROUND: While quantification of viral loads has been successfully employed in clinical medicine and has provided valuable insights and useful markers for several viral diseases, the potential of measuring bacterial DNA load to predict outcome or monitor therapeutic responses remains largely unexplored. We tested this possibility by investigating bacterial loads in Acinetobacter baumannii bacteremia, a rapidly increasing nosocomial infection characterized by high mortality, drug resistance, multiple and complicated risk factors, all of which urged the need of good markers to evaluate therapeutics. METHODS AND FINDINGS: We established a quantitative real-time PCR assay based on an A. baumannii-specific gene, Oxa-51, and conducted a prospective study to examine A. baumannii loads in 318 sequential blood samples from 51 adults patients (17 survivors, 34 nonsurvivors with culture-proven A. baumannii bacteremia in the intensive care units. Oxa-51 DNA loads were significantly higher in the nonsurvivors than survivors on day 1, 2 and 3 (P=0.03, 0.001 and 0.006, respectively. Compared with survivors, nonsurvivors had higher maximum Oxa-51 DNA load and a trend of increase from day 0 to day 3 (P<0.001, which together with Pitt bacteremia score were independent predictors for mortality by multivariate analysis (P=0.014 and 0.016, for maximum Oxa-51 DNA and change of Oxa-51 DNA, respectively. Kaplan-Meier analysis revealed significantly different survival curves in patients with different maximum Oxa-51 DNA and change of Oxa-51 DNA from day 0 to day 3. CONCLUSIONS: High Oxa-51 DNA load and its initial increase could predict mortality. Moreover, monitoring Oxa-51 DNA load in blood may provide direct parameters for evaluating new regimens against A. baumannii in future clinical studies.

  4. Finite element limit loads for non-idealized through-wall cracks in thick-walled pipe

    International Nuclear Information System (INIS)

    Shim, Do-Jun; Han, Tae-Song; Huh, Nam-Su

    2013-01-01

    Highlights: • The lower bound bulging factor of thin-walled pipe can be used for thick-walled pipe. • The limit loads are proposed for thick-walled, transition through-wall cracked pipe. • The correction factors are proposed for estimating limit loads of transition cracks. • The limit loads of short transition cracks are similar to those of idealized cracks. - Abstract: The present paper provides plastic limit loads for non-idealized through-wall cracks in thick-walled pipe. These solutions are based on detailed 3-dimensional finite element (FE) analyses which can be used for structural integrity assessment of nuclear piping. To cover a practical range of interest, the geometric variables and loading conditions affecting the plastic limit loads of thick-walled pipe with non-idealized through-wall cracks were systematically varied. In terms of crack orientation, both circumferential and axial through-wall cracks were considered. As for loading conditions, axial tension, global bending, and internal pressure were considered for circumferential cracks, whereas only internal pressure was considered for axial cracks. Furthermore, the values of geometric factor representing shape characteristics of non-idealized through-wall cracks were also systematically varied. In order to provide confidence in the present FE analyses results, plastic limit loads of un-cracked, thick-walled pipe resulting from the present FE analyses were compared with the theoretical solutions. Finally, correction factors to the idealized through-wall crack solutions were developed to determine the plastic limit loads of non-idealized through-wall cracks in thick-walled pipe

  5. Full-scale load tests of Pearl-Chain arches

    DEFF Research Database (Denmark)

    Halding, Philip Skov; Hertz, Kristian Dahl; Schmidt, Jacob Wittrup

    2017-01-01

    -Decks: First an investigation of the system’s elastic response (maximum load of 648kN), and second a demonstration of its collapse mechanism and ultimate capacity (maximum load of 970kN). The full-scale test showed formation of plastic hinges and clear warning signs are observed at 84% of the failure load......A full-scale load test is made of two Pearl-Chain (PC) concrete arches in order to evaluate the structural response and assess the design safety. Pearl-Chain structures and Pearl-Chain arches are invented and patented at the Technical University of Denmark. PC-Arches consist of specially designed....... The ultimate, experimental load capacity is 14% higher than the calculated mainly due to the assumed static system used for the calculation. In addition to the full-scale test bridge the first ever permanent PC-Bridge is erected in Denmark in 2015....

  6. Effect of Demographic Factors on E-Learning Effectiveness in a Higher Learning Institution in Malaysia

    Science.gov (United States)

    Islam, Md. Aminul; Rahim, Noor Asliza Abdul; Liang, Tan Chee; Momtaz, Hasina

    2011-01-01

    This research attempted to find out the effect of demographic factors on the effectiveness of the e-learning system in a higher learning Institution. The students from this institution were randomly selected in order to evaluate the effectiveness of learning system in student's learning process. The primary data source is the questionnaires that…

  7. The Flynn effect, group differences, and g loadings

    NARCIS (Netherlands)

    te Nijenhuis, J.

    2013-01-01

    Flynn effect gains are predominantly driven by environmental factors. Might these factors also be responsible for group differences in intelligence? Group differences in intelligence have been clearly shown to strongly correlate with g loadings. The empirical studies on whether the pattern of Flynn

  8. Postural loading assessment in assembly workers of an Iranian telecommunication manufacturing company.

    Science.gov (United States)

    Kamalinia, Mojtaba; Nasl Saraji, Gebreal; Kee, Dohyung; Hosseini, Mostafa; Choobineh, Alireza

    2013-01-01

    Changes in industries and work practices have coincided with work-related musculoskeletal disorders (MSDs). This study was conducted to determine the prevalence of MSDs and to assess postural loading in assembly workers of an Iranian telecommunication manufacturing company. Data were collected from 193 randomly selected workers in 4 units of the company. The Nordic musculoskeletal disorders questionnaire and the UBC ergonomic checklist were used as data collection tools. Loading on the upper body assessment (LUBA) was used to assess postural loading. Lower back symptoms were the most prevalent problems among the workers (67.9%). LUBA showed that most assembly workers (94.3%) had experienced considerable and high postural loading (postural load index, PLI > 5). Regression analyses revealed that lighting, rotation, contact stress, repetition, gender and age were factors associated with symptoms. Work-related MSDs occurred at a high rate among workers. Postural loading requires consideration. Any ergonomic intervention should focus on eliminating ergonomic factors associated with symptoms.

  9. Load Asymmetry Observed During Orion Main Parachute Inflation

    Science.gov (United States)

    Morris, Aaron L.; Taylor, Thomas; Olson, Leah

    2011-01-01

    The Crew Exploration Vehicle Parachute Assembly System (CPAS) has flight tested the first two generations of the Orion parachute program. Three of the second generation tests instrumented the dispersion bridles of the Main parachute with a Tension Measuring System. The goal of this load measurement was to better understand load asymmetry during the inflation process of a cluster of Main parachutes. The CPAS Main parachutes exhibit inflations that are much less symmetric than current parachute literature and design guides would indicate. This paper will examine loads data gathered on three cluster tests, quantify the degree of asymmetry observed, and contrast the results with published design guides. Additionally, the measured loads data will be correlated with videos of the parachute inflation to make inferences about the shape of the parachute and the relative load asymmetry. The goal of this inquiry and test program is to open a dialogue regarding asymmetrical parachute inflation load factors.

  10. Ultimate load model test for Sizewell 'B' primary containment

    International Nuclear Information System (INIS)

    Crowder, R.

    1988-01-01

    This paper considers the factors influencing the adoption of an ultimate load factor for the Sizewell 'B' PWR primary containment structure. As part of the validation process for the ultimate load analysis method, a proposal has been made by Nuclear Design Associates to build and test a 1/10th scale model of the containment structure, which would proceed following the granting of section 2 consent for Sizewell 'B'. The modelling principles, construction method and test proposals are examined in some detail. The proposal is currently being considered by the CEGB's Project Management Team. (author)

  11. SEASONAL CHANGES IN PHOSPHORUS LOAD FLOWING OUT OF SMALL AGRICULTURAL CATCHMENTS

    Directory of Open Access Journals (Sweden)

    Krzysztof Pulikowski

    2014-12-01

    Full Text Available In this article distribution of monthly phosphorus loads flowing out of two agricultural catchments which are located in different physiographic conditions of Lower Silesia was analysed. Loads of phosphorus runoff from the catchment located in the piedmont part of Lower Silesia in each month rarely exceed 0.10 kg P ∙ ha-1. The size of annual load is determined by loads obtained in two months of early spring. Much lower loads obtained for lowland catchment, located near Wroclaw. Values ​​calculated for each month rarely exceed the value of 0.01 kg P ∙ ha-1. Culmination of loads bringing away is a bit more extended in a time compared to the catchment located on Sudety Mts. Foreland. Much higher loads are observed during the period from January to April – this period has a major impact on the size of phosphorus load that flows out from this catchment during whole hydrological year. The obtained results clearly indicate that the threat of watercourses and water reservoirs supply in phosphorus compounds from agricultural land is periodic and it is particularly high during early spring. Phosphorus load flowing out from the analyzed catchments is very diverse. From facility located on Sudety Foothill in hydrological year, during research period, flowed away average 0.81 kg P ∙ ha-1. Significantly lower values were obtained for second facility and it was average 0.15 kg P ∙ ha-1 during a year. The size of load discharged during a year is largely determined by amount of phosphorus load flowing out during winter half of the year (from XI to IV. In case of foothill catchment in this period flowed out average 0.56 kg P ∙ ha-1, which presents 69% of annual load and in lowland catchment this percentage was even slightly higher and was 73%.

  12. Assessment of Replacement Bridge using Proof Load Test

    Science.gov (United States)

    Sundru, Saibabu

    2017-11-01

    This work begins with an overview of the condition assessment of old bridge and explained reasons for demolishing of the bridge. Briefly presented flexural analysis of two stage post-tensioned prestressed concrete girder, which will be replace the old (new bridge). Construction of I-girder and composite girder at first stage and second stage prestressing respectively is explained with figures. Assessment of the load-caring capacity of the one span of the replacement bridge with simple supports using proof load test is presented which is mandatory according to Indian standards. Weighted sand bags were used to load the bridge up to a predetermined service load with impact factor. Deflections of the I-girders of the bridge were measured at selected locations along and across the bridge span and compared with computed values. Linear response was observed during loading and unloading. Considering the load test results, theoretical estimation and criteria as stipulated in codes of practice, it can be inferred that prestressed concrete I-girder bridge span has adequate capacity to carry the loads and hence, deemed to have passed the test.

  13. Load research manual. Volume 1. Load research procedures

    Energy Technology Data Exchange (ETDEWEB)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussed in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.

  14. Development of novel sibutramine base-loaded solid dispersion with gelatin and HPMC: physicochemical characterization and pharmacokinetics in beagle dogs.

    Science.gov (United States)

    Lim, Hyun-Tae; Balakrishnan, Prabagar; Oh, Dong Hoon; Joe, Kwan Hyung; Kim, Young Ran; Hwang, Doo Hyung; Lee, Yong-Bok; Yong, Chul Soon; Choi, Han-Gon

    2010-09-15

    To develop a novel sibutramine base-loaded solid dispersion with enhanced solubility and bioavailability, various solid dispersions were prepared using a spray drying technique with hydrophilic polymers such as gelatin, HPMC and citric acid. Their solubility, thermal characteristics and crystallinity were investigated. The dissolution and pharmacokinetics of the sibutramine base-loaded solid dispersion were then compared with a sibutramine hydrochloride monohydrate-loaded commercial product (Reductil). The solid dispersions prepared with gelatin gave higher drug solubility than those prepared without gelatin, irrespective of the amount of polymer. The sibutramine base-loaded solid dispersions containing hydrophilic polymer and citric acid showed higher drug solubility compared to sibutramine base and sibutramine hydrochloride monohydrate. Among the formulations tested, the solid dispersion composed of sibutramine base/gelatin/HPMC/citric acid at the weight ratio of 1/0.8/0.2/0.5 gave the highest solubility of 5.03+/-0.24 mg/ml. Our DSC and powder X-ray diffraction results showed that the drug was present in an altered amorphous form in this solid dispersion. The difference factor (f(1)) values between solid dispersion and commercial product were 2.82, 6.65 and 6.31 at pH 1.2, 4.0 and 6.8, respectively. Furthermore, they had the similarity factor (f(2)) value of 65.68, 53.43 and 58.97 at pH 1.2, 4.0 and 6.8, respectively. Our results suggested that the solid dispersion and commercial product produced a similar correlation of dissolution profiles at all pH ranges. The AUC, C(max) and T(max) of the parent drug and metabolite I and II from the solid dispersion were not significantly different from those of the commercial product, suggesting that the solid dispersion might be bioequivalent to the commercial product in beagle dogs. Thus, the sibutramine base-loaded solid dispersion prepared with gelatin, HPMC and citric acid is a promising candidate for improving the

  15. Performance of composite I-beams under axial compression and bending load modes

    International Nuclear Information System (INIS)

    Khalid, Y.A.; Ali, F.A.; Sahari, B.B.; Saad, E.M.A.

    2005-01-01

    An experimental and finite-element analyses for glass/epoxy composite I-beams have been carried out. Four, six, eight and 10 layers of woven fabric glass/epoxy composite I-beams were fabricated by a hand lay-up (molding) process. Quasi-static axial crushing and bending loading modes were used for this investigation. The load-displacement response was obtained and the energy absorption values were calculated for all the composite I-beams. Three tests were done for each composite I-beams type and each loading case for the results conformation. The second part of this study includes the elastic behavior of composite I-beams of the same dimensions and materials using finite-element analysis. The woven fabric glass/epoxy composite I-beams mechanical properties have been obtained from tensile tests. Results from this investigation show that the load required and the specific energy absorption for composite I-beams under axial compression load were higher than those for three and four point bending. On the other hand, the loads required for composite I-beams under four point bending were higher than those for three point bending, while the specific energy absorption for composite I-beams under three point bending were higher than those for four point bending. The first crushing loads difference between the experimental and finite-element results fell in the 3.6-10.92% range for axial compression tests, while fell in the 1.44-12.99% and 4.94-22.0% range for three and four point bending, respectively

  16. Determination of current loads of floating platform for special purposes

    Science.gov (United States)

    Ma, Guang-ying; Yao, Yun-long; Zhao, Chen-yao

    2017-08-01

    This article studied a new floating offshore platform for special purposes, which was assembled by standard floating modules. The environmental load calculation of the platform is an important part of the research of the ocean platform, which has always been paid attention to by engineers. In addition to wave loads, the wind loads and current loads are also important environmental factors that affect the dynamic response of the offshore platform. The current loads on the bottom structure should not be ignored. By Fluent software, the hydrostatic conditions and external current loads of the platform were calculated in this paper. The coefficient which is independent of the current velocity, namely, current force coefficient, can be fitted through current loads, which can be used for the consequent hydrodynamic and mooring analyses.

  17. Cognitive load effects on early visual perceptual processing.

    Science.gov (United States)

    Liu, Ping; Forte, Jason; Sewell, David; Carter, Olivia

    2018-05-01

    Contrast-based early visual processing has largely been considered to involve autonomous processes that do not need the support of cognitive resources. However, as spatial attention is known to modulate early visual perceptual processing, we explored whether cognitive load could similarly impact contrast-based perception. We used a dual-task paradigm to assess the impact of a concurrent working memory task on the performance of three different early visual tasks. The results from Experiment 1 suggest that cognitive load can modulate early visual processing. No effects of cognitive load were seen in Experiments 2 or 3. Together, the findings provide evidence that under some circumstances cognitive load effects can penetrate the early stages of visual processing and that higher cognitive function and early perceptual processing may not be as independent as was once thought.

  18. Species With Greater Aerial Maneuverability Have Higher Frequency of Collisions With Aircraft: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Esteban Fernández-Juricic

    2018-03-01

    Full Text Available Antipredator responses may appear unsuccessful when animals are exposed to approaching vehicles, often resulting in mortality. Recent studies have addressed whether certain biological traits are associated with variation in collision risk with cars, but not with higher speed-vehicles like aircraft. Our goal was to establish the association between different species traits (i.e., body mass, eye size, brain size, wing loading, wing aspect ratio and the frequency of bird collisions with aircraft (hereafter, bird strikes using a comparative approach controlling for the effects of shared ancestry. We proposed directional predictions as to how each of the species traits would affect the frequency of bird strikes. Considering 39 bird species with all traits represented, the model containing wing loading had the best fit to account for the variance in bird strikes across species. In another model with 54 species exploring the fit to different polynomial models but considering only wing loading, we found that wing loading was negatively and linearly associated with the frequency of bird strikes. Counterintuitively, species with lower wing loading (hence, greater maneuverability had a higher frequency of bird strikes. We discuss potential non-mutually exclusive explanations (e.g., high wing loading species fly faster, thus gaining some extra time to avoid the aircraft flight path; high wing loading species are hazed more intensively at airports, which could lower collisions, etc.. Ultimately, our findings uncovered that species with low wing loading get struck at a higher rate at airports, which reduces the safety risk for humans because these species tend not to cause damaging strikes, but the ecological consequences of their potentially higher local mortality are unknown.

  19. Factors Influencing Assessment Quality in Higher Vocational Education

    Science.gov (United States)

    Baartman, Liesbeth; Gulikers, Judith; Dijkstra, Asha

    2013-01-01

    The development of assessments that are fit to assess professional competence in higher vocational education requires a reconsideration of assessment methods, quality criteria and (self)evaluation. This article examines the self-evaluations of nine courses of a large higher vocational education institute. Per course, 4-11 teachers and 3-10…

  20. Load power device, system and method of load control and management employing load identification

    Science.gov (United States)

    Yang, Yi; Luebke, Charles John; Schoepf, Thomas J.

    2018-01-09

    A load power device includes a power input, at least one power output for at least one load, a plurality of sensors structured to sense voltage and current at the at least one power output, and a processor. The processor provides: (a) load identification based upon the sensed voltage and current, and (b) load control and management based upon the load identification.

  1. Diffusion Indexes with Sparse Loadings

    DEFF Research Database (Denmark)

    Kristensen, Johannes Tang

    The use of large-dimensional factor models in forecasting has received much attention in the literature with the consensus being that improvements on forecasts can be achieved when comparing with standard models. However, recent contributions in the literature have demonstrated that care needs...... to the problem by using the LASSO as a variable selection method to choose between the possible variables and thus obtain sparse loadings from which factors or diffusion indexes can be formed. This allows us to build a more parsimonious factor model which is better suited for forecasting compared...... it to be an important alternative to PC....

  2. Factores de riesgo de cáncer cervicouterino invasor en mujeres mexicanas Risk factors in invasive cervical cancer among Mexican women

    Directory of Open Access Journals (Sweden)

    Laura Leticia Tirado-Gómez

    2005-10-01

    Papilloma Virus (HR-HPV (viral load and type 16, along with other gynecological and socioeconomic factors. MATERIAL AND METHODS: Individually matched case-control study (215 women with invasive CC and 420 controls. The study population was recruited between 2000 and 2001. A set of variables traditionally linked with CC (gynecological and socioeconomic factors and two variables related to HPV infection (viral load and type 16 were assessed. Hybrid Capture II was used to detect HR-HPV DNA. Viral load was measured by light measurements expressed as relative light units (RLU and they were categorized for analysis into four groups: negative (499 RLU. The analysis included univariate, bivariate and multivariate techniques being the final step the estimation of Odds Ratios (OR by means of conditional logistic regression models. RESULTS: The probability of having invasive CC was 78 times higher in patients with infection of HR-HPV. Risk increases with HPV type 16 (OR=429.7 as compared with other types of HR-HPV (OR=64.1. An important trend was observed with the increase of the viral load (from 46.6 with low viral load; to 250.7 with intermediate and 612.9 with high load. The findings also indicate significant diferences in the viral load between cases and controls according to age groups and HR-HPV types (16 versus others high risk types. Finally, the partner-demographic and obstetrical variables related to the disease increased the risk of invasive CC. No association between CC and smoking was observed in this population. CONCLUSIONS: This study helps in identifying women at higher risk of developing invasive CC as a subset of those patients infected with HR-HPV. The findings point strongly to the importance of the viral load in HR-HPV as a co-factor in the development of this disease. This biomarker contributes to improving the prevention and early detection of this disease and also to identify women at higher risk who carry a high viral load of HR-HPV.

  3. Study on Mechanical Properties of Barite Concrete under Impact Load

    Science.gov (United States)

    Chen, Z. F.; Cheng, K.; Wu, D.; Gan, Y. C.; Tao, Q. W.

    2018-03-01

    In order to research the mechanical properties of Barite concrete under impact load, a group of concrete compression tests was carried out under the impact load by using the drop test machine. A high-speed camera was used to record the failure process of the specimen during the impact process. The test results show that:with the increase of drop height, the loading rate, the peak load, the strain under peak load, the strain rate and the dynamic increase factor (DIF) all increase gradually. The ultimate tensile strain is close to each other, and the time of impact force decreases significantly, showing significant strain rate effect.

  4. Assessing the long term impact of phosphorus fertilization on phosphorus loadings using AnnAGNPS.

    Science.gov (United States)

    Yuan, Yongping; Bingner, Ronald L; Locke, Martin A; Stafford, Jim; Theurer, Fred D

    2011-06-01

    High phosphorus (P) loss from agricultural fields has been an environmental concern because of potential water quality problems in streams and lakes. To better understand the process of P loss and evaluate the effects of different phosphorus fertilization rates on phosphorus losses, the USDA Annualized AGricultural Non-Point Source (AnnAGNPS) pollutant loading model was applied to the Ohio Upper Auglaize watershed, located in the southern portion of the Maumee River Basin. In this study, the AnnAGNPS model was calibrated using USGS monitored data; and then the effects of different phosphorus fertilization rates on phosphorus loadings were assessed. It was found that P loadings increase as fertilization rate increases, and long term higher P application would lead to much higher P loadings to the watershed outlet. The P loadings to the watershed outlet have a dramatic change after some time with higher P application rate. This dramatic change of P loading to the watershed outlet indicates that a "critical point" may exist in the soil at which soil P loss to water changes dramatically. Simulations with different initial soil P contents showed that the higher the initial soil P content is, the less time it takes to reach the "critical point" where P loadings to the watershed outlet increases dramatically. More research needs to be done to understand the processes involved in the transfer of P between the various stable, active and labile states in the soil to ensure that the model simulations are accurate. This finding may be useful in setting up future P application and management guidelines.

  5. Prognostic factors for specific lower extremity and spinal musculoskeletal injuries identified through medical screening and training load monitoring in professional football (soccer): a systematic review

    Science.gov (United States)

    Sergeant, Jamie C; Parkes, Matthew J; Callaghan, Michael J

    2017-01-01

    Background Medical screening and load monitoring procedures are commonly used in professional football to assess factors perceived to be associated with injury. Objectives To identify prognostic factors (PFs) and models for lower extremity and spinal musculoskeletal injuries in professional/elite football players from medical screening and training load monitoring processes. Methods The MEDLINE, AMED, EMBASE, CINAHL Plus, SPORTDiscus and PubMed electronic bibliographic databases were searched (from inception to January 2017). Prospective and retrospective cohort studies of lower extremity and spinal musculoskeletal injury incidence in professional/elite football players aged between 16 and 40 years were included. The Quality in Prognostic Studies appraisal tool and the modified Grading of Recommendations Assessment, Development and Evaluation synthesis approach was used to assess the quality of the evidence. Results Fourteen studies were included. 16 specific lower extremity injury outcomes were identified. No spinal injury outcomes were identified. Meta-analysis was not possible due to heterogeneity and study quality. All evidence related to PFs and specific lower extremity injury outcomes was of very low to low quality. On the few occasions where multiple studies could be used to compare PFs and outcomes, only two factors demonstrated consensus. A history of previous hamstring injuries (HSI) and increasing age may be prognostic for future HSI in male players. Conclusions The assumed ability of medical screening tests to predict specific musculoskeletal injuries is not supported by the current evidence. Screening procedures should currently be considered as benchmarks of function or performance only. The prognostic value of load monitoring modalities is unknown. PMID:29177074

  6. Role of subchondral bone properties and changes in development of load-induced osteoarthritis in mice.

    Science.gov (United States)

    Adebayo, O O; Ko, F C; Wan, P T; Goldring, S R; Goldring, M B; Wright, T M; van der Meulen, M C H

    2017-12-01

    Animal models recapitulating post-traumatic osteoarthritis (OA) suggest that subchondral bone (SCB) properties and remodeling may play major roles in disease initiation and progression. Thus, we investigated the role of SCB properties and its effects on load-induced OA progression by applying a tibial loading model on two distinct mouse strains treated with alendronate (ALN). Cyclic compression was applied to the left tibia of 26-week-old male C57Bl/6 (B6, low bone mass) and FVB (high bone mass) mice. Mice were treated with ALN (26 μg/kg/day) or vehicle (VEH) for loading durations of 1, 2, or 6 weeks. Changes in articular cartilage and subchondral and epiphyseal cancellous bone were analyzed using histology and microcomputed tomography. FVB mice exhibited thicker cartilage, a thicker SCB plate, and higher epiphyseal cancellous bone mass and tissue mineral density than B6 mice. Loading induced cartilage pathology, osteophyte formation, and SCB changes; however, lower initial SCB mass and stiffness in B6 mice did not attenuate load-induced OA severity compared to FVB mice. By contrast, FVB mice exhibited less cartilage damage, and slower-growing and less mature osteophytes. In B6 mice, inhibiting bone remodeling via ALN treatment exacerbated cartilage pathology after 6 weeks of loading, while in FVB mice, inhibiting bone remodeling protected limbs from load-induced cartilage loss. Intrinsically lower SCB properties were not associated with attenuated load-induced cartilage loss. However, inhibiting bone remodeling produced differential patterns of OA pathology in animals with low compared to high SCB properties, indicating that these factors do influence load-induced OA progression. Copyright © 2017 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  7. Sample intake position and loading rates from nonpoint source pollution

    Science.gov (United States)

    McGuire, P. E.; Daniel, T. C.; Stoffel, D.; Andraski, B.

    1980-01-01

    Paired water samples were simultaneously activated from two different vertical positions within the approach section of a flow-control structure to determine the effect of sample intake position on nonpoint runoff parameter concentrations and subsequent event loads. Suspended solids (SS), total phosphorus (TP) and organic plus exchangeable nitrogen [(Or+Ex)-N] were consistently higher throughout each runoff event when sampled from the floor of the approach section as opposed to those samples taken at midstage. Dissolved molybdate reactive phosphorus (DMRP) and ammonium (NH4-N) concentrations did not appear to be significantly affected by the vertical difference in intake position. However, the nitrate plus nitrite nitrogen [(NO3+NO2)-N] concentrations were much higher when sampled from the midstage position. Although the concentration differences between the two methods were not appreciable, when evaluated in terms of event loads, discrepancies were evident for all parameters. Midstage sampling produced event loads for SS, TP, (Or + Ex)-N, DMRP, NH4-N, and (NO3+NO2)-N that were 44,39,35,80,71, and 181%, respectively, of floor sampling loads. Differences in loads between the two methods are attributed to the midstage position, sampling less of the bed load. The correct position will depend on the objective; however, such differences should be recognized during the design phase of the monitoring program.

  8. Higher HOMA-IR index and correlated factors of insulin resistance in patients with IgA nephropathy.

    Science.gov (United States)

    Yang, Yue; Wei, Ri-Bao; Wang, Yuan-da; Zhang, Xue-Guang; Rong, Na; Tang, Li; Chen, Xiang-Mei

    2012-11-01

    To investigate the index of homeostasis model of insulin resistance (HOMA-IR) in IgA nephropathy (IgAN) patients, and to explore the possible correlated factors contributing to insulin resistance (IR) within these patients. There were 255 IgAN patients and 45 membranous nephropathy (MN) patients in our database. We identified 89 IgAN subjects and 21 MN subjects without diabetes and undergoing glucocorticoid therapy for at least 6 months. Data regarding physical examination, blood chemistry and renal pathology were collected from 89 IgAN subjects and 21 MN subjects. Then 62 IgAN patients and 19 MN patients with chronic kidney disease (CKD) Stage 1 - 2 were selected for the comparison of HOMA-IR index, 89 IgAN patients were selected for multiple regression analysis to test for correlated factors of HOMA-IR index with IgAN patients. Comparison between IgAN and MN show that HOMA-IR index was significantly higher in IgAN patients with CKD Stage 1 - 2. After logarithmic transformation with urine protein (UPr), Ln(UPr) (b = 0.186, p = 0.008), eGFR (b = -0.005, p = 0.014), > 50% of glomeruli with mesangial hypercellularity (b = 0.285, p = 0.027) and body mass index (BMI) (b = 0.039, p = 0.008) were correlated factors of HOMA-IR index in the multiple regression analysis. IgAN patients had higher HOMA-IR index compared with MN in the stages of CKD 1 - 2. For IgAN patients, more UPr, lower eGFR, > 50% of glomeruli with mesangial hypercellularity and higher BMI were correlated with IR.

  9. Multiscale Thermohydrologic Model Analyses of Heterogeneity and Thermal-Loading Factors for the Proposed Repository at Yucca Mountain

    International Nuclear Information System (INIS)

    Glascoe, L.G.; Buscheck, T.A.; Gansemer, J.; Sun, Y.; Lee, K.

    2002-01-01

    The MultiScale ThermoHydrologic Model (MSTHM) predicts thermohydrologic (TH) conditions in emplacement drifts and the adjoining host rock throughout the proposed nuclear-waste repository at Yucca Mountain. The MSTHM is a computationally efficient approach that accounts for TH processes occurring at a scale of a few tens of centimeters around individual waste packages and emplacement drifts, and for heat flow at the multi-kilometer scale at Yucca Mountain. The modeling effort presented here is an early investigation of the repository and is simulated at a lower temperature mode and with a different panel loading than the repository currently being considered for license application. We present these recent lower temperature mode MSTHM simulations that address the influence of repository-scale thermal-conductivity heterogeneity and the influence of preclosure operational factors affecting thermal-loading conditions. We can now accommodate a complex repository layout with emplacement drifts lying in non-parallel planes using a superposition process that combines results from multiple mountain-scale submodels. This development, along with other improvements to the MSTHM, enables more rigorous analyses of preclosure operational factors. These improvements include the ability to (1) predict TH conditions on a drift-by-drift basis, (2) represent sequential emplacement of waste packages along the drifts, and (3) incorporate distance- and time-dependent heat-removal efficiency associated with drift ventilation. Alternative approaches to addressing repository-scale thermal-conductivity heterogeneity are investigated. We find that only one of the four MSTHM submodel types needs to incorporate thermal-conductivity heterogeneity. For a particular repository design, we find that the most influential parameters are (1) percolation-flux distribution, (2) thermal-conductivity heterogeneity within the host-rock units, (3) the sequencing of waste-package emplacement, and (4) the

  10. Higher prevalence of risk factors for type 2 diabetes mellitus and subsequent higher incidence in men

    DEFF Research Database (Denmark)

    Almdal, Thomas; Scharling, Henrik; Jensen, Jan Skov

    2008-01-01

    , non-fasting blood glucose and triglycerides. Significantly more men (242, 5.4%) than women (152, 2.5%) developed type 2 DM. The odds ratio (OR) for developing diabetes with a BMI above 30 kg/m(2) compared to a BMI of 20-25 kg/m(2) was 8.1 in women and 6.3 in men; for a non-fasting plasma glucose of 8.......4-11.0 mmol/l compared to a plasma glucose of 5.5-6.4, the ORs were 7.8 in women and 4.7 in men. The OR for developing diabetes in persons with a non-fasting triglyceride level above 2.0 mmol/l compared to 1.0-2.0 mmol/l was 1.8 in both sexes; women with non -fasting triglycerides below 1.0 mmol/l had...... or non-fasting plasma glucose >11.1 mmol/l) were excluded. Some 6154 women and 4733 men were studied and followed up in 1981-1983 or in 1991-1994. The significance of risk factors was examined by multiple logistic regression analysis. RESULTS: Initially, a higher proportion of men than women had high...

  11. LOADING OF MECHANICAL TRANSMISSION OF TROLLEYBUS TRACTION DRIVING GEAR

    Directory of Open Access Journals (Sweden)

    A. I. Safonov

    2009-01-01

    Full Text Available The paper analyzes factors that determine dynamic loads of mechanical transmission of trolleybus traction driving gear. The paper proposes a methodology for determination of calculative moments of loading transmission elements. Results of the research are analyzed and recommendations on  dynamic reduction of trolleybus transmission are given in the paper. 

  12. Higher Education Marketing Strategies Based on Factors Impacting the Enrollees' Choice of a University and an Academic Program

    Science.gov (United States)

    Kalimullin, Aydar M.; Dobrotvorskaya, Svetlana G.

    2016-01-01

    The relevance of studying the stated problem is due to the fact that for increasing the efficiency of higher education marketing it is necessary to take into account several factors, namely, factors that impact the choice of a university and an academic program by enrollees, as well as socio-psychological characteristics of the latter, while…

  13. Factors Affecting Corporate Image from the Perspective of Distance Learning Students in Public Higher Education Institutions

    Science.gov (United States)

    da Costa, Fábio Reis; Pelissari, Anderson Soncini

    2016-01-01

    New information technologies enable different interactions in the educational environment, affecting how the image of educational institutions adopting distance-learning programmes is perceived. This article identifies factors affecting the perception of corporate image from the viewpoint of distance-learning students at public higher education…

  14. Impact of Higher Fidelity Models on Simulation of Active Aerodynamic Load Control For Fatigue Damage Reduction

    NARCIS (Netherlands)

    Resor, B.; Wilson, D.; Berg, D.; Berg, J.; Barlas, T.; Van Wingerden, J.W.; Van Kuik, G.A.M.

    2010-01-01

    Active aerodynamic load control of wind turbine blades is being investigated by the wind energy research community and shows great promise, especially for reduction of turbine fatigue damage in blades and nearby components. For much of this work, full system aeroelastic codes have been used to

  15. Performance of women with fibromyalgia in walking up stairs while carrying a load

    Directory of Open Access Journals (Sweden)

    Daniel Collado-Mateo

    2016-02-01

    Full Text Available Background. Fibromyalgia is a chronic disease characterized by widespread pain and other associated symptoms. It has a relevant impact on physical fitness and the ability to perform daily living tasks. The objective of the study was to analyze the step-by-step-performance and the trunk tilt of women with fibromyalgia in the 10-step stair climbing test compared with healthy controls. Methods. A cross-sectional study was carried out. Twelve women suffering from fibromyalgia and eight healthy controls were recruited from a local association. Participants were asked to climb 10 stairs without carrying a load and 10 stairs carrying a load of 5 kg in each hand. Mediolateral trunk tilt was assessed using the “Functional Assessment of Biomechanics (FAB” wireless motion capture device, and the time between steps was assessed via weight-bearing insoles. Results. Trunk tilt in the stair-climbing task carrying a load was significantly higher in women with fibromyalgia when compared to the healthy controls (2.31 (0.63 vs. 1.69 (0.51 respectively. The effect of carrying a load was significantly higher for women with fibromyalgia compared with healthy controls at the intermediate and final part of the task. Discussion. Trunk tilt during stair climbing while carrying a load was higher in women with FM, which could increase the risk of falling. Additionally, women with FM experienced a higher pace slowdown as a consequence of the load, which supports the need of including specific strength and resistance training to physical therapies for this population.

  16. Performance of women with fibromyalgia in walking up stairs while carrying a load.

    Science.gov (United States)

    Collado-Mateo, Daniel; Adsuar, José C; Olivares, Pedro R; Dominguez-Muñoz, Francisco J; Maestre-Cascales, Cristina; Gusi, Narcis

    2016-01-01

    Background. Fibromyalgia is a chronic disease characterized by widespread pain and other associated symptoms. It has a relevant impact on physical fitness and the ability to perform daily living tasks. The objective of the study was to analyze the step-by-step-performance and the trunk tilt of women with fibromyalgia in the 10-step stair climbing test compared with healthy controls. Methods. A cross-sectional study was carried out. Twelve women suffering from fibromyalgia and eight healthy controls were recruited from a local association. Participants were asked to climb 10 stairs without carrying a load and 10 stairs carrying a load of 5 kg in each hand. Mediolateral trunk tilt was assessed using the "Functional Assessment of Biomechanics (FAB)" wireless motion capture device, and the time between steps was assessed via weight-bearing insoles. Results. Trunk tilt in the stair-climbing task carrying a load was significantly higher in women with fibromyalgia when compared to the healthy controls (2.31 (0.63) vs. 1.69 (0.51) respectively). The effect of carrying a load was significantly higher for women with fibromyalgia compared with healthy controls at the intermediate and final part of the task. Discussion. Trunk tilt during stair climbing while carrying a load was higher in women with FM, which could increase the risk of falling. Additionally, women with FM experienced a higher pace slowdown as a consequence of the load, which supports the need of including specific strength and resistance training to physical therapies for this population.

  17. Gearbox Reliability Collaborative Investigation of High-Speed-Shaft Bearing Loads

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Guo, Yi [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-06-01

    The loads and contact stresses in the bearings of the high speed shaft section of the Gearbox Reliability Collaborative gearbox are examined in this paper. The loads were measured though strain gauges installed on the bearing outer races during dynamometer testing of the gearbox. Loads and stresses were also predicted with a simple analytical model and higher-fidelity commercial models. The experimental data compared favorably to each model, and bearing stresses were below thresholds for contact fatigue and axial cracking.

  18. Concentrations and loads of suspended sediment-associated pesticides in the San Joaquin River, California and tributaries during storm events

    Science.gov (United States)

    Hladik, M.L.; Domagalski, Joseph L.; Kuivila, K.M.

    2009-01-01

    Current-use pesticides associated with suspended sediments were measured in the San Joaquin River, California and its tributaries during two storm events in 2008. Nineteen pesticides were detected: eight herbicides, nine insecticides, one fungicide and one insecticide synergist. Concentrations for the herbicides (0.1 to 3000 ng/g; median of 6.1 ng/g) were generally greater than those for the insecticides (0.2 to 51 ng/g; median of 1.5 ng/g). Concentrations in the tributaries were usually greater than in the mainstem San Joaquin River and the west side tributaries were higher than the east side tributaries. Estimated instantaneous loads ranged from 1.3 to 320 g/day for herbicides and 0.03 to 53 g/day for insecticides. The greatest instantaneous loads came from the Merced River on the east side. Instantaneous loads were greater for the first storm of 2008 than the second storm in the tributaries while the instantaneous loads within the San Joaquin River were greater during the second storm. Pesticide detections generally reflected pesticide application, but other factors such as physical-chemical properties and timing of application were also important to pesticide loads.

  19. The effects of loading history on fatigue crack growth threshold

    International Nuclear Information System (INIS)

    Ogawa, Takeshi; Tokaji, Keiro; Ochi, Satoshi; Kobayashi, Hideo.

    1987-01-01

    The effects of loading history on threshold stress intensity range (ΔK th ) were investigated in a low alloy steel SFVQ1A (A508 - 3) and a low carbon steel S10C. A single overload and multiple overloads were chosen as loading history. Crack growth and crack closure following the loading histories were measured at load ratios of 0.05 and 0.70. Threshold values were determined as a fatigue limit of preloaded specimens. The ΔK th values increased with increasing overload stress intensity factor (K h ). For a given K h value, multiple overloads produced much larger increase in ΔK th than a single overload and threshold values expressed by maximum stress intensity factor (K max,th ) were almost constant, independent of stress ratio. The results obtained were discussed in terms of crack closure behaviour, and a method was proposed to evaluate the threshold value based on plasticity-induced crack closure. (author)

  20. The Unintentional Memory Load in Tests for Young Children.

    Science.gov (United States)

    Jones, Margaret Hubbard

    The validity of certain standardized tests may be affected by the short-term memory load therein and its relation to a child's short-term memory capacity. Factors of testing which increase a test's memory load and consequently interfere with comprehension are discussed. It is hypothesized that a test which strains the short-term memory capacity of…

  1. Physical Modelling of Bucket Foundations Subjected to Axial Loading

    DEFF Research Database (Denmark)

    Vaitkunaite, Evelina

    Compared to oil and gas structures, marine renewable energy devices are usually much lighter, operate in shallower waters and are subjected to severe cyclic loading and dynamic excitations. These factors result in different structural behaviours. Bucket foundations are a potentially cost......-effective solution for various offshore structures, and not least marine renewables. The present thesis focuses on several critical design problems related to the behaviour of bucket foundations exposed to tensile loading. Among those are the soil-structure interface parameters, tensile loading under various...

  2. TEACHERS' PERSPECTIVE ABOUT FACTORS THAT PREVENT SUCCESS IN TEACHING AND LEARNING PROCESS IN HIGHER EDUCATION OF ENGINEERING IN BRAZIL

    Directory of Open Access Journals (Sweden)

    Gláucia Nolasco de Almeida Mello

    2016-12-01

    Full Text Available The last fifteen years, in Brazil, the number of engineering freshmen had a huge increased and, although the number of graduated also had increased over the same period, the percentage of engineering freshmen are by far higher than engineers graduated. In this context, there is a clear evidence of the high dropout rate in higher education courses of engineering in Brazil. Once most of developed researches about engineering courses dropout in Brazil are focused in the students and institutions point of view about factors that affect dropout rate, in this research it was investigated the professors perspective to answer the three questions: (1 What are the main factors which prevent success in teaching and learning process identified by professors of engineering during the classes? (2 How can professors to improve the teaching and learning process in higher education courses of engineering in Brazil? (3 How can Higher Education Institutions (HEI support the professors? The research data were collected through team activities developed with 134 professors of higher education courses of engineering. This research reveals that the most important factors that affect negatively the teaching and learning process are related to inadequate high school preparation and behaviour of students. Main suggestions of professors for improving the teaching and learning process and also students' motivation are related to pedagogical aspects such as: use of Information and Communication Technologies (ICTs as support of classes and implementation of professor and student support programs with significant participation of HEI.

  3. Applying to Higher Education: Information Sources and Choice Factors

    Science.gov (United States)

    Simoes, Claudia; Soares, Ana Maria

    2010-01-01

    Higher education institutions are facing increasingly complex challenges, which demand a deeper understanding of the sources prospective students use when applying to a higher education institution. This research centres on students' decision-making process for higher education institutions, focusing on the pre-purchase period, and, in particular,…

  4. A Hybrid Power Control Concept for PV Inverters with Reduced Thermal Loading

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2014-01-01

    on a single-phase PV inverter under yearly operation is presented with analyses of the thermal loading, lifetime, and annual energy yield. It has revealed the trade-off factors to select the power limit and also verified the feasibility and the effectiveness of the proposed control concept.......This letter proposes a hybrid power control concept for grid-connected Photovoltaic (PV) inverters. The control strategy is based on either a Maximum Power Point Tracking (MPPT) control or a Constant Power Generation (CPG) control depending on the instantaneous available power from the PV panels....... The essence of the proposed concept lies in the selection of an appropriate power limit for the CPG control to achieve an improved thermal performance and an increased utilization factor of PV inverters,and thus to cater for a higher penetration level of PV systems with intermittent nature. A case study...

  5. Characterization of wear debris from metal-on-metal hip implants during normal wear versus edge-loading conditions.

    Science.gov (United States)

    Kovochich, Michael; Fung, Ernest S; Donovan, Ellen; Unice, Kenneth M; Paustenbach, Dennis J; Finley, Brent L

    2018-04-01

    Advantages of second-generation metal-on-metal (MoM) hip implants include low volumetric wear rates and the release of nanosized wear particles that are chemically inert and readily cleared from local tissue. In some patients, edge loading conditions occur, which result in higher volumetric wear. The objective of this study was to characterize the size, morphology, and chemistry of wear particles released from MoM hip implants during normal (40° angle) and edge-loading (65° angle with microseparation) conditions. The mean primary particle size by volume under normal wear was 35 nm (range: 9-152 nm) compared with 95 nm (range: 6-573 nm) under edge-loading conditions. Hydrodynamic diameter analysis by volume showed that particles from normal wear were in the nano- (edge-loading conditions generated particles that ranged from Edge-loading conditions generated more elongated particles (4.5%) (aspect ratio ≥ 2.5) and more CoCr alloy particles (9.3%) compared with normal wear conditions (1.3% CoCr particles). By total mass, edge-loading particles contained approximately 640-fold more cobalt than normal wear particles. Our findings suggest that high wear conditions are a potential risk factor for adverse local tissue effects in MoM patients who experience edge loading. This study is the first to characterize both the physical and chemical characteristics of MoM wear particles collected under normal and edge-loading conditions. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 986-996, 2018. © 2017 Wiley Periodicals, Inc.

  6. Three Dimensional Parametric Analyses of Stress Concentration Factor and Its Mitigation in Isotropic and Orthotropic Plate with Central Circular Hole Under Axial In-Plane Loading

    Science.gov (United States)

    Nagpal, Shubhrata; Jain, Nitin Kumar; Sanyal, Shubhashis

    2016-01-01

    The problem of finding the stress concentration factor of a loaded rectangular plate has offered considerably analytical difficulty. The present work focused on understanding of behavior of isotropic and orthotropic plate subjected to static in-plane loading using finite element method. The complete plate model configuration has been analyzed using finite element method based software ANSYS. In the present work two parameters: thickness to width of plate (T/A) and diameter of hole to width of plate (D/A) have been varied for analysis of stress concentration factor (SCF) and its mitigation. Plates of five different materials have been considered for complete analysis to find out the sensitivity of stress concentration factor. The D/A ratio varied from 0.1 to 0.7 for analysis of SCF and varied from 0.1 to 0.5 for analyzing the mitigation of SCF. 0.01, 0.05 and 0.1 are considered as T/A ratio for all the cases. The results are presented in graphical form and discussed. The mitigation in SCF reported is very encouraging. The SCF is more sensitive to D/A ratio as compared to T/A.

  7. Calculating load factors for the transatlantic airline market using supply and demand data: a note on the identification of gaps in the available airline statistics

    NARCIS (Netherlands)

    Devriendt, L.; Burghouwt, G.; Derudder, B.; de Wit, J.; Witlox, F.

    2009-01-01

    This paper takes a critical view of the verification of load factors for the direct transatlantic airline market by combining supply and demand-data. The supply-related data originate from the Official Airline Guide, a well-known data source that contains information on scheduled flights. The

  8. Crop load and harvest maturity effects on consumer preferences for apricots.

    Science.gov (United States)

    Stanley, Jill; Feng, Jinquan; Olsson, Shane

    2015-03-15

    Improving apricot fruit quality delivered to consumers is key to ensuring a successful apricot industry. Previous studies have focused on effects of either soluble solids content (SSC) or fruit firmness on consumer preferences, and results have been equivocal. This study evaluated the effects of crop load and harvest maturity how they affected on fruit SSC and firmness, and on subsequent consumer preferences. SSC of apricots was an important factor only when fruit were firmer than 15 N and not immature. When fruit were softer than 15 N, SSC had little influence on consumer liking. In general, consumers preferred fruit that were grown on trees thinned to approximately 10-20% less than typical commercial crop loads and were harvested in a more mature condition. Consumers also preferred fruit that had a higher sugar/acid ratio or BrimA value, which is the °Brix - k × titratable acidity, where k is a constant that varies between species and cultivars depending on the specific acids and sugars present. High apricot flavour and juiciness were associated with greater sweetness. Management practices that increase fruit SSC and sugar/acid ratio, such as reducing crop load, will improve consumer satisfaction as long as fruit are harvested at an adequate maturity stage and are maintained in storage so that they do not soften too quickly. © 2014 Society of Chemical Industry.

  9. Load shape development for Swedish commercial and public buildings - methodologies and results

    Energy Technology Data Exchange (ETDEWEB)

    Noren, C.

    1999-06-01

    The knowledge concerning electricity consumption, and especially load demand, in Swedish commercial buildings is very limited. The current study deals with methods for electricity consumption indicator development and application of the different methodologies on measured data. Typical load shapes and consumption indicators are developed for four different types of commercial buildings: schools, hotels, grocery stores and department stores. Two different methodologies for consumption indicator development are presented and discussed. The influence on load demand from different factors such as, installations, outdoor temperature and building activities is studied. It is suggested that building floor area is not an accurate determinant of building electricity consumption and it is necessary to consider other factors as those just mentioned to understand commercial building electricity consumption. The application of the two methodologies on measured data shows that typical load shapes can be developed with reasonable accuracy. For most of the categories it is possible to use the typical load shapes for approximation of whole-building load shapes with error rates about 10-25% depending on day-type and building type. Comparisons of the developed load shapes with measured data show good agreement 49 refs, 22 figs, 3 tabs

  10. Loading direction regulates the affinity of ADP for kinesin.

    Science.gov (United States)

    Uemura, Sotaro; Ishiwata, Shin'ichi

    2003-04-01

    Kinesin is an ATP-driven molecular motor that moves processively along a microtubule. Processivity has been explained as a mechanism that involves alternating single- and double-headed binding of kinesin to microtubules coupled to the ATPase cycle of the motor. The internal load imposed between the two bound heads has been proposed to be a key factor regulating the ATPase cycle in each head. Here we show that external load imposed along the direction of motility on a single kinesin molecule enhances the binding affinity of ADP for kinesin, whereas an external load imposed against the direction of motility decreases it. This coupling between loading direction and enzymatic activity is in accord with the idea that the internal load plays a key role in the unidirectional and cooperative movement of processive motors.

  11. Decreasing Cognitive Load for Learners: Strategy of Web-Based Foreign Language Learning

    Science.gov (United States)

    Zhang, Jianfeng

    2013-01-01

    Cognitive load is one of the important factors that influence the effectiveness and efficiency of web-based foreign language learning. Cognitive load theory assumes that human's cognitive capacity in working memory is limited and if it overloads, learning will be hampered, so that high level of cognitive load can affect the performance of learning…

  12. Confirmatory factor analysis of teaching and learning guiding principles instrument among teacher educators in higher education institutions

    Science.gov (United States)

    Masuwai, Azwani; Tajudin, Nor'ain Mohd; Saad, Noor Shah

    2017-05-01

    The purpose of this study is to develop and establish the validity and reliability of an instrument to generate teaching and learning guiding principles using Teaching and Learning Guiding Principles Instrument (TLGPI). Participants consisted of 171 Malaysian teacher educators. It is an essential instrument to reflect in generating the teaching and learning guiding principles in higher education level in Malaysia. Confirmatory Factor Analysis has validated all 19 items of TLGPI whereby all items indicated high reliability and internal consistency. A Confirmatory Factor Analysis also confirmed that a single factor model was used to generate teaching and learning guiding principles.

  13. Factors That Influence the Diffusion Process of Mobile Devices in Higher Education in Botswana and Namibia

    Science.gov (United States)

    Asino, Tutaleni I.

    2015-01-01

    This comparative study uses the Diffusion of Innovation (DoI) theoretical framework to explore factors that influence diffusion of mobile devices in higher education in Botswana and Namibia. The five attributes (Relative Avantage, Compatability, Complexity, Trialability, and Observability) of the persuasion stage, which have been found in previous…

  14. Personal Efficacy and Factors of Effective Learning Environment in Higher Education: Croatian and American Students

    Directory of Open Access Journals (Sweden)

    Violeta Vidaček - Hainš

    2010-06-01

    Full Text Available Successful learning in higher education incorporates various factors related to knowledge, skills, habits, and motivation. Additionally, students’ personalities and self-efficacy may contribute to their adjustment, planning of activities, and achieving success. The objective of this paper is to analyze students’ needs for support services, which enhance the effectiveness of their learning environment at higher education institutions. Answers received from a sample of undergraduate freshmen at one American University and one Croatian University were analyzed and compared. The students from both countries agree that there is a need for developing self-reliance and personal responsibility in using support services, as well as for the timely and accurate information on availability of these services. Students’ suggestions and their desire to enhance effectiveness of their learning environment may be used in creating and improving support services in higher education institutions as well as training their staff.

  15. Structural analysis of the ITER vacuum vessel from disruption loading with halo asymmetry

    International Nuclear Information System (INIS)

    Riemer, B.W.; Sayer, R.O.

    1996-01-01

    Static structural analyses of the ITER vacuum vessel were performed with toroidally asymmetric disruption loads. Asymmetric halo current conditions were assumed to modify symmetric disruption loads which resulted in net lateral loading on the vacuum vessel torus. Structural analyses with the asymmetric loading indicated significantly higher vessel stress and blanket support forces than with symmetric disruption loads. A recent change in the vessel support design which provided toroidal constraints at each mid port was found to be effective in reducing torus lateral movement and vessel stress

  16. The role of the demand-duration curve in the evaluation of power station installation policies. Remarks on its effects on stations' utilization, generating capacity, load factor history and consumptions

    International Nuclear Information System (INIS)

    Graziani, G.; Maineri, M.; Zanantoni, C.

    1976-12-01

    The role of the load-duration curve in determining the installation policy for an electric power system, is examined. The effect of the priority order for the allocation of the power stations in the load-diagram is also discussed: in the model used here (program TOTEM) this priority is given as a function of type and age of the station. The significance of the load factor history for a power station as a function of its age is also discussed. It is suggested that such a curve be deduced as a result of strategy calculations made with TOTEM rather than assumping it as input data

  17. Conceptual and methodological concerns in the theory of perceptual load.

    Science.gov (United States)

    Benoni, Hanna; Tsal, Yehoshua

    2013-01-01

    The present paper provides a short critical review of the theory of perceptual load. It closely examines the basic tenets and assumptions of the theory and identifies major conceptual and methodological problems that have been largely ignored in the literature. The discussion focuses on problems in the definition of the concept of perceptual load, on the circularity in the characterization and manipulation of perceptual load and the confusion between the concept of perceptual load and its operationalization. The paper also selectively reviews evidence supporting the theory as well as inconsistent evidence which proposed alternative dominant factors influencing the efficacy of attentional selection.

  18. Load Disaggregation Technologies: Real World and Laboratory Performance

    Energy Technology Data Exchange (ETDEWEB)

    Mayhorn, Ebony T.; Sullivan, Greg P.; Petersen, Joseph M.; Butner, Ryan S.; Johnson, Erica M.

    2016-09-28

    Low cost interval metering and communication technology improvements over the past ten years have enabled the maturity of load disaggregation (or non-intrusive load monitoring) technologies to better estimate and report energy consumption of individual end-use loads. With the appropriate performance characteristics, these technologies have the potential to enable many utility and customer facing applications such as billing transparency, itemized demand and energy consumption, appliance diagnostics, commissioning, energy efficiency savings verification, load shape research, and demand response measurement. However, there has been much skepticism concerning the ability of load disaggregation products to accurately identify and estimate energy consumption of end-uses; which has hindered wide-spread market adoption. A contributing factor is that common test methods and metrics are not available to evaluate performance without having to perform large scale field demonstrations and pilots, which can be costly when developing such products. Without common and cost-effective methods of evaluation, more developed disaggregation technologies will continue to be slow to market and potential users will remain uncertain about their capabilities. This paper reviews recent field studies and laboratory tests of disaggregation technologies. Several factors are identified that are important to consider in test protocols, so that the results reflect real world performance. Potential metrics are examined to highlight their effectiveness in quantifying disaggregation performance. This analysis is then used to suggest performance metrics that are meaningful and of value to potential users and that will enable researchers/developers to identify beneficial ways to improve their technologies.

  19. Instructional Benefits of Spoken Words: A Review of Cognitive Load Factors

    Science.gov (United States)

    Kalyuga, Slava

    2012-01-01

    Spoken words have always been an important component of traditional instruction. With the development of modern educational technology tools, spoken text more often replaces or supplements written or on-screen textual representations. However, there could be a cognitive load cost involved in this trend, as spoken words can have both benefits and…

  20. Shoulder joint loading and posture during medicine cart pushing task.

    Science.gov (United States)

    Xu, Xu; Lin, Jia-Hua; Boyer, Jon

    2013-01-01

    Excessive physical loads and awkward shoulder postures during pushing and pulling are risk factors for shoulder pain. Pushing a medicine cart is a major component of a work shift for nurses and medical assistants in hospitals and other health care facilities. A laboratory experiment was conducted to examine the effects of common factors (e.g., lane congestion, cart load stability, floor surface friction) on shoulder joint moment and shoulder elevation angle of participants during cart pushing. Participants pushed a medicine cart on straight tracks and turning around right-angle corners. Peak shoulder joint moments reached 25.1 Nm, 20.3 Nm, and 26.8 Nm for initial, transition, and turning phases of the pushing tasks, indicating that shoulder joint loading while pushing a medical cart is comparable to levels previously reported from heavy manual activities encountered in industry (e.g., garbage collection). Also, except for user experience, all other main study factors, including congestion level, cart load stability, location of transition strip, shoulder tendency, surface friction, and handedness, significantly influenced shoulder joint moment and shoulder elevation angle. The findings provide a better understanding of shoulder exposures associated with medicine cart operations and may be helpful in designing and optimizing the physical environment where medicine carts are used.

  1. Assessing Power System Stability Following Load Changes and Considering Uncertainty

    Directory of Open Access Journals (Sweden)

    D. V. Ngo

    2018-04-01

    Full Text Available An increase in load capacity during the operation of a power system usually causes voltage drop and leads to system instability, so it is necessary to monitor the effect of load changes. This article presents a method of assessing the power system stability according to the load node capacity considering uncertainty factors in the system. The proposed approach can be applied to large-scale power systems for voltage stability assessment in real-time.

  2. Crack assessment of pipe under combined thermal and mechanical load

    International Nuclear Information System (INIS)

    Song, Tae Kwang; Kim, Yun Jae

    2009-01-01

    In this paper, J-integral and transient C(t)-integral, which were key parameters in low temperature and high temperature fracture mechanics, under combined thermal and mechanical load were estimated via 3-dimensional finite element analyses. Various type of thermal and mechanical load, material hardening were considered to decrease conservatism in existing solutions. As a results, V-factor and redistribution time for combined thermal and mechanical load were proposed to calculate J-integral and C(t)-integral, respectively.

  3. Macrophyte Community Response to Nitrogen Loading and ...

    Science.gov (United States)

    Empirical determination of nutrient loading thresholds that negatively impact seagrass communities have been elusive due to the multitude of factors involved. Using a mesocosm system that simulated Pacific Northwest estuaries, we evaluated macrophyte metrics across gradients of NO3 loading (0, 1.5, 3 and 6x ambient) and temperature (10 and 20 °C). Macroalgal growth, biomass, and C:N responded positively to increased NO3 load and floating algal mats developed at 20 ºC. Zostera japonica metrics, including C:N, responded more to temperature than to NO3 loading. Z. marina biomass exhibited a negative temperature effect and in some cases a negative NO3 effect, while growth rate increased with temperature. Shoot survival decreased at 20 ºC but was not influenced by NO3 loading. Wasting disease index exhibited a significant temperature by NO3 interaction consistent with increased disease susceptibility. Community shifts observed were consistent with the nutrient loading hypothesis at 20 ºC, but there was no evidence of other eutrophication symptoms due to the short residence time. The Nutrient Pollution Index tracked the NO3 gradient at 10 ºC but exhibited no response at 20 ºC. We suggest that systems characterized by cool temperatures, high NO3 loads, and short residence time may be resilient to many symptoms of eutrophication. Estuarine systems characterized by cool temperatures, high nutrient loads and rapid flushing may be resilient to some symptoms

  4. Separating method factors and higher order traits of the Big Five: a meta-analytic multitrait-multimethod approach.

    Science.gov (United States)

    Chang, Luye; Connelly, Brian S; Geeza, Alexis A

    2012-02-01

    Though most personality researchers now recognize that ratings of the Big Five are not orthogonal, the field has been divided about whether these trait intercorrelations are substantive (i.e., driven by higher order factors) or artifactual (i.e., driven by correlated measurement error). We used a meta-analytic multitrait-multirater study to estimate trait correlations after common method variance was controlled. Our results indicated that common method variance substantially inflates trait correlations, and, once controlled, correlations among the Big Five became relatively modest. We then evaluated whether two different theories of higher order factors could account for the pattern of Big Five trait correlations. Our results did not support Rushton and colleagues' (Rushton & Irwing, 2008; Rushton et al., 2009) proposed general factor of personality, but Digman's (1997) α and β metatraits (relabeled by DeYoung, Peterson, and Higgins (2002) as Stability and Plasticity, respectively) produced viable fit. However, our models showed considerable overlap between Stability and Emotional Stability and between Plasticity and Extraversion, raising the question of whether these metatraits are redundant with their dominant Big Five traits. This pattern of findings was robust when we included only studies whose observers were intimately acquainted with targets. Our results underscore the importance of using a multirater approach to studying personality and the need to separate the causes and outcomes of higher order metatraits from those of the Big Five. We discussed the implications of these findings for the array of research fields in which personality is studied.

  5. Phosphorous loads evaluation from soil

    International Nuclear Information System (INIS)

    Mezzanotte, V.

    1996-01-01

    With reference to the well known difficulty of quantifying non point phosphorous loads, as well as to their growing relative importance where point source leads decrease, a literature review has been carried out concerning soil export coefficients. On such basis, the values which seem to be the most appropriate for Italy have been estimated for different land use categories. The main mechanisms determining non point phosphorous load generation and the factors affecting their importance are also described. In the end, criteria for estimating the importance of non point sources in a basin are suggested to be used for deciding whether a traditional, parametric assessment (inevitably involving a certain error) can be acceptable or experimental measures are needed

  6. Genetic Ancestry and Susceptibility to Late-Onset Alzheimer Disease (LOAD) in the Admixed Colombian Population.

    Science.gov (United States)

    Moreno, Diana J; Pino, Sebastián; Ríos, Ángela; Lopera, Francisco; Ostos, Henry; Via, Marc; Bedoya, Gabriel

    2017-01-01

    Differences in the prevalence of dementia among populations and in the effect of apolipoprotein E (APOE) on the emergence of Alzheimer disease (AD), which is the main type of dementia, have been reported. This study estimated the ancestry of a group of individuals with late-onset Alzheimer disease (LOAD) (N=280) and established whether there were any differences when compared with a control group (N=357) in a sample of the Colombian population. When the analyses were adjusted for known risk factors such as age, sex, presence of APOE[Latin Small Letter Open E]4, socioeconomic status, educational attainment, and place of birth, African ancestry was associated with an increased LOAD risk (odds ratio: 1.55; 95% confidence interval, 1.09-2.03; P=0.029), whereas Native American ancestry was associated with lower risk (odds ratio: 0.75; 95% confidence interval, 0.61-0.98; P=0.046), for every 10% increase in ancestry. In addition, there were significant differences in the proportion of Native American ancestry between carriers and noncarriers of the APOE[Latin Small Letter Open E]4 allele (Mann-Whitney U test, P=0.047), with noncarriers having higher mean Native American ancestry when compared with carriers. Our results are consistent with the presence of variants of African origin in the genome of the Colombian population and different from APOE[Latin Small Letter Open E]4 that represents a risk factor for the development of LOAD, whereas variants of Native American origin may be conferring protection. However, unknown environmental factors or epigenetic differences among continental groups could also explain the observed associations.

  7. Effect of loading rate on dynamic fracture of reaction bonded silicon nitride

    Science.gov (United States)

    Liaw, B. M.; Kobayashi, A. S.; Emery, A. F.

    1986-01-01

    Wedge-loaded, modified tapered double cantilever beam (WL-MTDCB) specimens under impact loading were used to determine the room temperature dynamic fracture response of reaction bonded silicon nitride (RBSN). The crack extension history, with the exception of the terminal phase, was similar to that obtained under static loading. Like its static counterpart, a distinct crack acceleration phase, which was not observed in dynamic fracture of steel and brittle polymers, was noted. Unlike its static counterpart, the crack continued to propagate at nearly its terminal velocity under a low dynamic stress intensity factor during the terminal phase of crack propagation. These and previously obtained results for glass and RBSN show that dynamic crack arrest under a positive dynamic stress intensity factor is unlikely in static and impact loaded structural ceramics.

  8. Effect of the change in the load resistance on the high voltage pulse transformer of the intense electron-beam accelerators.

    Science.gov (United States)

    Cheng, Xin-bing; Liu, Jin-liang; Qian, Bao-liang; Zhang, Yu; Zhang, Hong-bo

    2009-11-01

    A high voltage pulse transformer (HVPT) is usually used as a charging device for the pulse forming line (PFL) of intense electron-beam accelerators (IEBAs). Insulation of the HVPT is one of the important factors that restrict the development of the HVPT. Until now, considerable effort has been focused on minimizing high field regions to avoid insulation breakdown between windings. Characteristics of the HVPT have been widely discussed to achieve these goals, but the effects of the PFL and load resistance on HVPT are usually neglected. In this paper, a HVPT is used as a charging device for the PFL of an IEBA and the effect of the change in the load resistance on the HVPT of the IEBA is presented. When the load resistance does not match the wave impedance of the PFL, a high-frequency bipolar oscillating voltage will occur, and the amplitude of the oscillating voltage will increase with the decrease in the load resistance. The load resistance approximates to zero and the amplitude of the oscillating voltage is much higher. This makes it easier for surface flashover along the insulation materials to form and decrease the lifetime of the HVPT.

  9. Lower head integrity under steam explosion loads

    Energy Technology Data Exchange (ETDEWEB)

    Theofanous, T.G.; Yuen, W.W.; Angelini, S.; Freeman, K.; Chen, X.; Salmassi, T. [Center for Risk Studies and Safety, Univ. of California, Santa Barbara, CA (United States); Sienicki, J.J.

    1998-01-01

    Lower head integrity under steam explosion loads in an AP600-like reactor design is considered. The assessment is the second part of an evaluation of the in-vessel retention idea as a severe accident management concept, the first part (DOE/ID-10460) dealing with thermal loads. The assessment is conducted in terms of the Risk Oriented Accident Analysis Methodology (ROAAM), and includes the comprehensive evaluation of all relevant severe accident scenarios, melt conditions and timing of release from the core region, fully 3D mixing and explosion wave dynamics, and lower head fragility under local, dynamic loading. All of these factors and brought together in a ROAAM Probabilistic Framework to evaluate failure likelihood. The conclusion is that failure is `physically unreasonable`. (author)

  10. Childhood Cumulative Risk and Later Allostatic Load

    DEFF Research Database (Denmark)

    Doan, Stacey N; Dich, Nadya; Evans, Gary W

    2014-01-01

    State, followed for 8 years (between the ages 9 and 17). Poverty- related stress was computed using the cumulative risk approach, assessing stressors across 9 domains, including environmental, psychosocial, and demographic factors. Allostatic load captured a range of physiological responses, including......Objective: The present study investigated the long-term impact of exposure to poverty-related stressors during childhood on allostatic load, an index of physiological dysregulation, and the potential mediating role of substance use. Method: Participants (n = 162) were rural children from New York...... cardiovascular, hypothalamic pituitary adrenal axis, sympathetic adrenal medullary system, and metabolic activity. Smoking and alcohol/drug use were tested as mediators of the hypothesized childhood risk-adolescent allostatic load relationship. Results: Cumulative risk exposure at age 9 predicted increases...

  11. Does vertical integration have an effect on load factor? - A test on coal-fired plants in England and Wales

    International Nuclear Information System (INIS)

    Lopez, Jose A.; Salies, Evens

    2006-02-01

    Today in the British electricity industry, most electricity suppliers hedge a large proportion of their residential customer base requirements by owning their own plant. The non-storability of electricity and the corresponding need for an instantaneous matching of generation and consumption creates a business need for integration. From a sample of half-hour data on load factor for coal-fired power plants in England and Wales, this paper tests the hypothesis that vertical integration with retail businesses affects the extent to which producers utilize their capacity. We also pay attention to this potential effect during periods of peak demand. (authors)

  12. Applicability of Various Load Test Interpretation Criteria in Measuring Driven Precast Concrete Pile Uplift Capacity

    Directory of Open Access Journals (Sweden)

    Maria Cecilia M. Marcos

    2018-04-01

    Full Text Available This paper presented a comprehensive analysis of load test interpretation criteria to determine their suitability to driven precast concrete (PC pile uplift capacity. A database was developed containing static pile load tests and utilized for the evaluation. The piles were round and square cross-sections under drained and undrained loading. To explore and compare their behavior, the stored data were categorized into four groups. In general, the trends of every criterion for the four groups were notably the same. In both drained and undrained loading, slightly larger interpreted capacities were demonstrated by square piles than by round piles. Moreover, round piles demonstrated more ductile load-displacement response than square piles especially in undrained loading. Statistical analyses presented that smaller values of displacements exhibited higher coefficient of variation. The drained and undrained tests were compared and results showed less variability in drained than undrained loading and capacity ratios (Qx/QCHIN in drained loading were slightly higher than in undrained loading. The interrelationship and applicability of these criteria as well as the design recommendations in terms of normalized capacity and displacement were given based on the analyses.

  13. Khat chewing among students of higher education in Jazan region, Saudi Arabia: prevalence, pattern, and related factors.

    Science.gov (United States)

    Alsanosy, Rashad Mohammed; Mahfouz, Mohamed Salih; Gaffar, Abdelrahim Mutwakel

    2013-01-01

    (1) To estimate the prevalence and behavioral patterns of Khat chewing and (2) to investigate factors that influenced the pattern of Khat use among undergraduate students in different higher education institutions in Jazan region, Saudi Arabia. A cross-sectional study using a pretested structured self-administered quantitative questionnaire was used to collect data. SPSS version 17 software program was used for data analysis. The overall current Khat chewing prevalence among higher education students was found to be 23.1%, significantly higher among males at 38.5% than among females at 2.1% (P higher compared with females at 3.7% (P higher education students in Jazan region. A multilevel, value based, comprehensive, and strategic long-term intervention plan is needed. The comprehensive plan may include social interventions geared by creating recreations alternatives and opportunities for youth and a critical review for current authorities' interventions and services.

  14. Pre-aeration of food waste to augment acidogenic process at higher organic load: Valorizing biohydrogen, volatile fatty acids and biohythane.

    Science.gov (United States)

    Sarkar, Omprakash; Venkata Mohan, S

    2017-10-01

    Application of pre-aeration (AS) to waste prior to feeding was evaluated on acidogenic process in a semi-pilot scale biosystem for the production of biobased products (biohydrogen, volatile fatty acids (VFA) and biohythane) from food waste. Oxygen assisted in pre-hydrolysis of waste along with the suppression of methanogenic activity resulting in enhanced acidogenic product formation. AS operation resulted in 97% improvement in hydrogen conversion efficiency (HCE) and 10% more VFA production than the control. Increasing the organic load (OL) of food waste in association with AS application improved the productivity. The application of AS also influenced concentration and composition of fatty acid. Highest fraction of acetic (5.3g/l), butyric (0.7g/l) and propionic acid (0.84g/l) was achieved at higher OL (100g COD/l) with good degree of acidification (DOA). AS strategy showed positive influence on biofuel (biohydrogen and biohythane) production along with the biosynthesis of short chain fatty acids functioning as a low-cost pretreatment strategy in a single stage bioprocess. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Distribution load forecast with interactive correction of horizon loads

    International Nuclear Information System (INIS)

    Glamochanin, V.; Andonov, D.; Gagovski, I.

    1994-01-01

    This paper presents the interactive distribution load forecast application that performs the distribution load forecast with interactive correction of horizon loads. It consists of two major parts implemented in Fortran and Visual Basic. The Fortran part is used for the forecasts computations. It consists of two methods: Load Transfer Coupling Curve Fitting (LTCCF) and load Forecast Using Curve Shape Clustering (FUCSC). LTCCF is used to 'correct' the contaminated data because of load transfer among neighboring distribution areas. FUCSC uses curve shape clustering to forecast the distribution loads of small areas. The forecast for each small area is achieved by using the shape of corresponding cluster curve. The comparison of forecasted loads of the area with historical data will be used as a tool for the correction of the estimated horizon load. The Visual Basic part is used to provide flexible interactive user-friendly environment. (author). 5 refs., 3 figs

  16. In vivo strains in the femur of the Virginia opossum (Didelphis virginiana) during terrestrial locomotion: testing hypotheses of evolutionary shifts in mammalian bone loading and design.

    Science.gov (United States)

    Butcher, Michael T; White, Bartholomew J; Hudzik, Nathan B; Gosnell, W Casey; Parrish, John H A; Blob, Richard W

    2011-08-01

    Terrestrial locomotion can impose substantial loads on vertebrate limbs. Previous studies have shown that limb bones from cursorial species of eutherian mammals experience high bending loads with minimal torsion, whereas the limb bones of non-avian reptiles (and amphibians) exhibit considerable torsion in addition to bending. It has been hypothesized that these differences in loading regime are related to the difference in limb posture between upright mammals and sprawling reptiles, and that the loading patterns observed in non-avian reptiles may be ancestral for tetrapod vertebrates. To evaluate whether non-cursorial mammals show loading patterns more similar to those of sprawling lineages, we measured in vivo strains in the femur during terrestrial locomotion of the Virginia opossum (Didelphis virginiana), a marsupial that uses more crouched limb posture than most mammals from which bone strains have been recorded, and which belongs to a clade phylogenetically between reptiles and the eutherian mammals studied previously. The presence of substantial torsion in the femur of opossums, similar to non-avian reptiles, would suggest that this loading regime likely reflects an ancestral condition for tetrapod limb bone design. Strain recordings indicate the presence of both bending and appreciable torsion (shear strain: 419.1 ± 212.8 με) in the opossum femur, with planar strain analyses showing neutral axis orientations that placed the lateral aspect of the femur in tension at the time of peak strains. Such mediolateral bending was unexpected for a mammal running with near-parasagittal limb kinematics. Shear strains were similar in magnitude to peak compressive axial strains, with opossum femora experiencing similar bending loads but higher levels of torsion compared with most previously studied mammals. Analyses of peak femoral strains led to estimated safety factor ranges of 5.1-7.2 in bending and 5.5-7.3 in torsion, somewhat higher than typical mammalian values

  17. Neural Network Algorithm for Particle Loading

    International Nuclear Information System (INIS)

    Lewandowski, J.L.V.

    2003-01-01

    An artificial neural network algorithm for continuous minimization is developed and applied to the case of numerical particle loading. It is shown that higher-order moments of the probability distribution function can be efficiently renormalized using this technique. A general neural network for the renormalization of an arbitrary number of moments is given

  18. Disengagement from tasks as a function of cognitive load and depressive symptom severity.

    Science.gov (United States)

    Bowie, Christopher R; Milanovic, Melissa; Tran, Tanya; Cassidy, Sarah

    2017-01-01

    Depression is associated with impairment in cognition and everyday functioning. Mechanisms of cognitive dysfunction in depression and the factors that influence strategic deployment of cognitive abilities in complex environments remain elusive. In this study we investigated whether depression symptom severity is associated with disengagement from a working memory task (Paced Auditory Serial Addition Task; PASAT) with parametric adjustment of task difficulty. 235 participants completed the Beck Depression Inventory, low and high cognitive load conditions of the PASAT, and quality of life. Cognitive disengagement was the sum of consecutive items in which participants did not proffer a response to the trial. Individuals with higher depression severity showed more cognitive disengagement on the high but not low cognitive load trial of the PASAT; they did not differ in number of correct responses. Increased disengagement from the low to high cognitive load was associated with more impaired quality of life. Depression severity is associated with increased disengagement from tasks as difficulty increases. These findings suggest the importance of measuring how cognitive skills are avoided in complex environments in addition to considering performance accuracy. Individuals with depressive symptoms might preferentially avoid cognitive tasks that are perceived as more complex in spite of intact ability.

  19. Short-Term City Electric Load Forecasting with Considering Temperature Effects: An Improved ARIMAX Model

    Directory of Open Access Journals (Sweden)

    Herui Cui

    2015-01-01

    Full Text Available Short-term electric load is significantly affected by weather, especially the temperature effects in summer. External factors can result in mutation structures in load data. Under the influence of the external temperature factors, city electric load cannot be easily forecasted as usual. This research analyzes the relationship between electricity load and daily temperature in city. An improved ARIMAX model is proposed in this paper to deal with the mutation data structures. It is found that information amount of the improved ARIMAX model is smaller than that of the classic method and its relative error is less than AR, ARMA and Sigmoid-Function ANN models. The forecasting results are more accurately fitted. This improved model is highly valuable when dealing with mutation data structure in the field of load forecasting. And it is also an effective technique in forecasting electric load with temperature effects.

  20. Subharmonic beam-loading in electron linear accelerators

    International Nuclear Information System (INIS)

    Gallagher, W.J.

    1983-01-01

    The intention of operating an electron linear accelerator subharmonically beam loaded for free electron laser application requires justification of the beam-loaded energy gain equation. The mode of operation typically planned is 5 to 10 nanocoulombs single RF cycle pulses at 25 to 50 nanosecond intervals. This inquiry investigates the details of this sort of beam loading and discusses the performance achievable. Several other investigations of single bunch beam loading have been undertaken, notably at SLAC, where it has been found experimentally that the beam-loading varies directly as the bunch charge and independently of its energy; that investigation also included radiation effects of the wake field and losses owing to parasitic effects of higher order modes. In the case of beam loading where there are multiple pulses transiting at the same time, and spaced far enough apart that significant RF power is introduced between pulses, the energy gain may be calculated by dividing the waveguide into a number of segments, each equal in length to the integral of the interpulse time and the local group velocity. Equations which reveal that the net energy gain in the steady state is the sum of the energy gains in these segments, which compute the initial field intensity, and which calculate the energy gain in the subharmonic case on the basis of the equivalent beam current are presented

  1. α-Cyclodextrins Polyrotaxane Loading Silver Sulfadiazine

    Directory of Open Access Journals (Sweden)

    Sa Liu

    2018-02-01

    Full Text Available As a drug carrier, polyrotaxane (PR has been used for targeted delivery and sustained release of drugs, whereas silver sulfadiazine (SD-Ag is an emerging antibiotic agent. PR was synthesized by the use of α-cyclodextrin (CD and poly(ethylene glycol (PEG, and a specific antibacterial material (PR-(SD-Ag was then prepared by loading SD-Ag onto PR with different mass ratios. The loading capacity and the encapsulation efficiency were 90% at a mass ratio of 1:1 of PR and SD-Ag. SD-Ag was released stably and slowly within 6 d in vitro, and its cumulative release reached more than 85%. The mechanism of PR loading SD-Ag might be that SD-Ag attached to the edge of α-CD through hydrogen bonding. PR-(SD-Ag showed a higher light stability than SD-Ag and held excellent antibacterial properties against Escherichia coli (E. coli and Staphylococcus aureus (S. aureus.

  2. Influence of loading distribution on the performance of high pressure turbine blades

    Science.gov (United States)

    Corriveau, Daniel

    Midspan measurements were made in a transonic wind tunnel for three High Pressure (HP) turbine blade cascades at both design and off-design incidences. Comparisons with two-dimensional numerical simulations of the cascade flow were also made. The baseline profile is the midspan section of a HP turbine blade of fairly recent design. It is considered mid-loaded. To gain a better understanding of blade loading limits and the influence of loading distributions, the profile of the baseline airfoil was modified to create two new airfoils having aft-loaded and front-loaded pressure distributions. Tests were performed for exit Mach numbers between 0.6 and 1.2. In addition, measurements were made for an extended range of Reynolds numbers for constant Mach numbers of 0.6, 0.85, 0.95 and 1.05. At the design exit Mach number of 1.05 and at design incidence, the aft-loaded airfoil showed a reduction of almost 20% in the total pressure losses compared with the baseline airfoil. Based on the analysis of wake traverse data and base pressure measurements combined with numerical results, it was found that the poorer loss performance of the baseline mid-loaded profile compared to the aft-loaded blade could be attributed to the former's higher rear suction side curvature, which resulted in higher flow velocity in that region, which, in turn, contributed to reducing the base pressure. The lower base pressure at the trailing edge resulted in a stronger trailing edge shock system for the mid-loaded blade. This shock system increased the losses for the mid-loaded baseline profile when compared to the aft-loaded profile. On the negative side, it was also found that as Mach numbers were increased beyond the design value the performance of the aft-loaded blade deteriorated rapidly. Under such conditions, the front-loaded airfoil showed generally inferior performance compared with the baseline airfoil. At off-design incidence, the aft-loaded blade maintained a superior loss performance over a

  3. Climate change effects on runoff, catchment phosphorus loading and lake ecological state, and potential adaptations.

    Science.gov (United States)

    Jeppesen, Erik; Kronvang, Brian; Meerhoff, Mariana; Søndergaard, Martin; Hansen, Kristina M; Andersen, Hans E; Lauridsen, Torben L; Liboriussen, Lone; Beklioglu, Meryem; Ozen, Arda; Olesen, Jørgen E

    2009-01-01

    Climate change may have profound effects on phosphorus (P) transport in streams and on lake eutrophication. Phosphorus loading from land to streams is expected to increase in northern temperate coastal regions due to higher winter rainfall and to a decline in warm temperate and arid climates. Model results suggest a 3.3 to 16.5% increase within the next 100 yr in the P loading of Danish streams depending on soil type and region. In lakes, higher eutrophication can be expected, reinforced by temperature-mediated higher P release from the sediment. Furthermore, a shift in fish community structure toward small and abundant plankti-benthivorous fish enhances predator control of zooplankton, resulting in higher phytoplankton biomass. Data from Danish lakes indicate increased chlorophyll a and phytoplankton biomass, higher dominance of dinophytes and cyanobacteria (most notably of nitrogen fixing forms), but lower abundance of diatoms and chrysophytes, reduced size of copepods and cladocerans, and a tendency to reduced zooplankton biomass and zooplankton:phytoplankton biomass ratio when lakes warm. Higher P concentrations are also seen in warm arid lakes despite reduced external loading due to increased evapotranspiration and reduced inflow. Therefore, the critical loading for good ecological state in lakes has to be lowered in a future warmer climate. This calls for adaptation measures, which in the northern temperate zone should include improved P cycling in agriculture, reduced loading from point sources, and (re)-establishment of wetlands and riparian buffer zones. In the arid Southern Europe, restrictions on human use of water are also needed, not least on irrigation.

  4. Surface heat loads on the ITER divertor vertical targets

    Czech Academy of Sciences Publication Activity Database

    Gunn, J. P.; Carpentier-Chouchana, S.; Escourbiac, F.; Hirai, T.; Panayotis, S.; Pitts, R.A.; Corre, Y.; Dejarnac, Renaud; Firdaouss, M.; Kočan, M.; Komm, Michael; Kukushkin, A.; Languille, P.; Missirlian, M.; Zhao, W.; Zhong, G.

    2017-01-01

    Roč. 57, č. 4 (2017), č. článku 046025. ISSN 0029-5515 Institutional support: RVO:61389021 Keywords : ITER * divertor * ELM heat load * inter-ELM heat load * tungsten Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 3.307, year: 2016 http://iopscience.iop.org/article/10.1088/1741-4326/aa5e2a

  5. Loading rate effect on the fracture behaviour of highstrength concrete

    Directory of Open Access Journals (Sweden)

    Del Viso J.

    2010-06-01

    Full Text Available This research deals with the sensitivity of eight types of performancedesigned high-strength concrete to the loading rate. Variations in the composition of the concrete produce the desired performance, for instance having null shrinkage or being able to be pumped at elevated heights without segregation, but they also produce variations in the fracture properties that are reported in this paper. We performed tests at five loading rates spanning six orders of magnitude in the displacement rate, from 1.74 × 10-5 mm/s to 17.4 mm/s. Load-displacement curves show that their peak is higher as the displacement rate increases, whereas the corresponding displacement is almost constant. Fracture energy also increases, but only for loading rates higher than 0.01 mm/s. We use a formula based on a cohesive law with a viscous term to study the results. The correlation of the formula to the experimental results is good and it allows us to obtain the theoretical value for the fracture energy under strictly static conditions. In addition, both the fracture energy and the characteristic length of the concretes used in the study diminish as the compressive strength of their aggregates increases.

  6. Load leveling by a battery system in an electric power system with a photovoltaic system; Taiyoko hatsuden system ga donyusareta denryoku keito no chikudenchi ni yoru fuka heijunka

    Energy Technology Data Exchange (ETDEWEB)

    Kenmoku, Y.; Sakakibara, T. [Toyohashi University of Technology, Aichi (Japan); Nakagawa, S. [Maizuru College of Technology, Kyoto (Japan); Kawamoto, T. [Shizuoka University, Shizuoka (Japan)

    1997-11-25

    Storage battery-aided load leveling system is introduced into a power system having a photovoltaic power generation (PV) system, and the effect of the introduction is examined. For this purpose, the resultant improvement on the load factor and reduction in the annual cost are evaluated. Used as the load factor in the studies are the hourly records of power transmitted and received by Chubu Electric Power Co., Inc., in 1995. The output of the PV system is calculated using weather data collected in Nagoya City in the same year. Findings as the result of the studies are stated below. The maximum power is suppressed but a little if it is only the PV system that is introduced into the system. That is, a 2GW PV system introduced into the system suppresses the maximum power only by 0.5GW or less. The maximum power is suppressed more effectively when a storage battery is added, and it decreases linearly with an increase in the storage battery capacity. As for reduction in the cost, the reducing effect is higher when the rate of storage battery capacity/introduced PV capacity is higher in the presence of an introduced PV capacity of 0.8GW or more. 2 refs., 7 figs., 3 tabs.

  7. Probability based load combinations for design of category I structures

    International Nuclear Information System (INIS)

    Reich, M.; Hwang, H.

    1985-01-01

    This paper discusses a reliability analysis method and a procedure for developing the load combination design criteria for category I structures. For safety evaluation of category I concrete structures under various static and dynamic loads, a probability-based reliability analysis method has been developed. This reliability analysis method is also used as a tool for determining the load factors for design of category I structures. In this paper, the load combinations for design of concrete containments, corresponding to a target limit state probability of 1.0 x 10 -6 in 4 years, are described. A comparison of containments designed using the ASME code and the proposed design criteria is also presented

  8. Conceptual and Methodological Concerns in the Theory of Perceptual Load

    Directory of Open Access Journals (Sweden)

    Hanna eBenoni

    2013-08-01

    Full Text Available The present paper provides a short critical review of the theory of perceptual load. It closely examines the basic tenets and assumptions of the theory and identifies major conceptual and methodological problems that have been largely ignored in the literature. The discussion focuses on problems in the definition of the concept of perceptual load, on the circularity in the characterization and manipulation of perceptual load and the confusion between the concept of perceptual load and its operationalization. The paper also selectively reviews evidence supporting the theory as well as inconsistent evidence which proposed alternative dominant factors influencing the efficacy of attentional selection.

  9. The effect of mechanical loads on the degradation of aliphatic biodegradable polyesters.

    Science.gov (United States)

    Li, Ying; Chu, Zhaowei; Li, Xiaoming; Ding, Xili; Guo, Meng; Zhao, Haoran; Yao, Jie; Wang, Lizhen; Cai, Qiang; Fan, Yubo

    2017-06-01

    Aliphatic biodegradable polyesters have been the most widely used synthetic polymers for developing biodegradable devices as alternatives for the currently used permanent medical devices. The performances during biodegradation process play crucial roles for final realization of their functions. Because physiological and biochemical environment in vivo significantly affects biodegradation process, large numbers of studies on effects of mechanical loads on the degradation of aliphatic biodegradable polyesters have been launched during last decades. In this review article, we discussed the mechanism of biodegradation and several different mechanical loads that have been reported to affect the biodegradation process. Other physiological and biochemical factors related to mechanical loads were also discussed. The mechanical load could change the conformational strain energy and morphology to weaken the stability of the polymer. Besides, the load and pattern could accelerate the loss of intrinsic mechanical properties of polymers. This indicated that investigations into effects of mechanical loads on the degradation should be indispensable. More combination condition of mechanical loads and multiple factors should be considered in order to keep the degradation rate controllable and evaluate the degradation process in vivo accurately. Only then can the degradable devise achieve the desired effects and further expand the special applications of aliphatic biodegradable polyesters.

  10. Future energy loads for a large-scale adoption of electric vehicles in the city of Los Angeles: Impacts on greenhouse gas (GHG) emissions

    International Nuclear Information System (INIS)

    Kim, Jae D.; Rahimi, Mansour

    2014-01-01

    Using plug-in electric vehicles (PEVs) has become an important component of greenhouse gas (GHG) emissions reduction strategy in the transportation sector. Assessing the net effect of PEVs on GHG emissions, however, is dependent on factors such as type and scale of electricity generation sources, adoption rate, and charging behavior. This study creates a comprehensive model that estimates the energy load and GHG emissions impacts for the years 2020 and 2030 for the city of Los Angeles. For 2020, model simulations show that the PEV charging loads will be modest with negligible effects on the overall system load profile. Contrary to previous study results, the average marginal carbon intensity is higher if PEV charging occurs during off-peak hours. These results suggest that current economic incentives to encourage off-peak charging result in greater GHG emissions. Model simulations for 2030 show that PEV charging loads increase significantly resulting in potential generation shortages. There are also significant grid operation challenges as the region's energy grid is required to ramp up and down rapidly to meet PEV loads. For 2030, the average marginal carbon intensity for off-peak charging becomes lower than peak charging mainly due to the removal of coal from the power generation portfolio. - Highlights: • Future energy load from PEV charging in the city of Los Angeles is modeled. • Changes in the marginal carbon intensity of the region's electric grid are modeled. • In the short run, offpeak charging results in higher marginal carbon intensity. • There is a mismatch between emissions and economic incentives for charging

  11. Formulation and Optimization of Celecoxib-Loaded Microspheres ...

    African Journals Online (AJOL)

    factors in the preparation of celecoxib-loaded microspheres. Methods: ... made with biodegradable polymers, are ... filtration on Whatman filter paper no.1 and washed 4 - 5 times with n-hexane [11]. The product was then air-dried at room.

  12. Study on Impact of Electric Vehicles Charging Models on Power Load

    Science.gov (United States)

    Cheng, Chen; Hui-mei, Yuan

    2017-05-01

    With the rapid increase in the number of electric vehicles, which will lead the power load on grid increased and have an adversely affect. This paper gives a detailed analysis of the following factors, such as scale of the electric cars, charging mode, initial charging time, initial state of charge, charging power and other factors. Monte Carlo simulation method is used to compare the two charging modes, which are conventional charging and fast charging, and MATLAB is used to model and simulate the electric vehicle charging load. The results show that compared with the conventional charging mode, fast charging mode can meet the requirements of fast charging, but also bring great load to the distribution network which will affect the reliability of power grid.

  13. Treadmill Exercise with Increased Body Loading Enhances Post Flight Functional Performance

    Science.gov (United States)

    Bloomberg, J. J.; Batson, C. D.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Laurie, S.; Lee, S. M. C.; Miller, C. A.; Mulavara, A. P.; Peters, B. T.; hide

    2014-01-01

    The goals of the Functional Task Test (FTT) study were to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. Ultimately this information will be used to assess performance risks and inform the design of countermeasures for exploration class missions. We have previously shown that for Shuttle, ISS and bed rest subjects functional tasks requiring a greater demand for dynamic control of postural equilibrium (i.e. fall recovery, seat egress/obstacle avoidance during walking, object translation, jump down) showed the greatest decrement in performance. Functional tests with reduced requirements for postural stability (i.e. hatch opening, ladder climb, manual manipulation of objects and tool use) showed little reduction in performance. These changes in functional performance were paralleled by similar decrements in sensorimotor tests designed to specifically assess postural equilibrium and dynamic gait control. The bed rest analog allows us to investigate the impact of axial body unloading in isolation on both functional tasks and on the underlying physiological factors that lead to decrements in performance and then compare them with the results obtained in our space flight study. These results indicate that body support unloading experienced during space flight plays a central role in postflight alteration of functional task performance. Given the importance of body-support loading we set out to determine if there is a relationship between the load experienced during inflight treadmill exercise (produced by a harness and bungee system) and postflight functional performance. ISS crewmembers (n=13) were tested using the FTT protocol before and after 6 months in space. Crewmembers were tested three times before flight, and on 1, 6, and 30 days after landing. To determine how differences in body

  14. Mathematical solution of the stone column effect on the load bearing capacity and settlement using numerical analysis

    Science.gov (United States)

    Madun, A.; Meghzili, S. A.; Tajudin, SAA; Yusof, M. F.; Zainalabidin, M. H.; Al-Gheethi, A. A.; Dan, M. F. Md; Ismail, M. A. M.

    2018-04-01

    The most important application of various geotechnical construction techniques is for ground improvement. Many soil improvement project had been developed due to the ongoing increase in urban and industrial growth and the need for greater access to lands. Stone columns are one of the best effective and feasible techniques for soft clay soil improvement. Stone columns increase the bearing capacity and reduce the settlement of soil. Finite element analyses were performed using the program PLAXIS 2D. An elastic-perfectly plastic constitutive relation, based on the Mohr–Coulomb criterion, governs the soft clay and stone column behaviour. This paper presents on how the response surface methodology (RSM) software is used to optimize the effect of the diameters and lengths of column on the load bearing capacity and settlement of soft clay. Load tests through the numerical modelling using Plaxis 2D were carried out on the loading plate at 66 mm. Stone column load bearing capacity increases with the increasing diameter of the column and settlement decreases with the increasing length of the column. Results revealed that the bigger column diameter, the higher load bearing capacity of soil while the longer column length, the lower settlement of soil. However, the optimum design of stone column was varied with each factor (diameter and length) separately for improvement.

  15. Reliability of Estimation Pile Load Capacity Methods

    Directory of Open Access Journals (Sweden)

    Yudhi Lastiasih

    2014-04-01

    Full Text Available None of numerous previous methods for predicting pile capacity is known how accurate any of them are when compared with the actual ultimate capacity of piles tested to failure. The author’s of the present paper have conducted such an analysis, based on 130 data sets of field loading tests. Out of these 130 data sets, only 44 could be analysed, of which 15 were conducted until the piles actually reached failure. The pile prediction methods used were: Brinch Hansen’s method (1963, Chin’s method (1970, Decourt’s Extrapolation Method (1999, Mazurkiewicz’s method (1972, Van der Veen’s method (1953, and the Quadratic Hyperbolic Method proposed by Lastiasih et al. (2012. It was obtained that all the above methods were sufficiently reliable when applied to data from pile loading tests that loaded to reach failure. However, when applied to data from pile loading tests that loaded without reaching failure, the methods that yielded lower values for correction factor N are more recommended. Finally, the empirical method of Reese and O’Neill (1988 was found to be reliable enough to be used to estimate the Qult of a pile foundation based on soil data only.

  16. Photo-catalysis water splitting by platinum-loaded zeolite A

    Science.gov (United States)

    Cheng, Jing; Gao, Changda; Jing, Ming; Lu, Jian; Lin, Hui; Han, Zhaoxia; Ni, Zhengji; Zhang, Dawei

    2018-05-01

    Under the λ≥420 nm visible light illumination, the Pt4+ ions exchanged LTA zeolite powders without further heat-treatment presented H2 evolution at a rate of 5 μl/(15 mg·h) via photocatalysis water splitting. It was shown that the efficiency of H2 generation by the Pt4+ exchanged LTA zeolite powders without further heat-treatment was higher than the counterpart of the samples with heat treatment. In addition, the samples with lower Pt loading concentration showed higher H2 evolution rate than those of higher Pt loading did. The higher H2 evolution efficiency can be attributed to the effective isolation of water molecules and Pt at the atomic or the few atom ‘cluster’ scale by LTA zeolite’s periodical porous structure, which ensures a more efficient electron transfer efficiency for H2 evolution. However, after extra heat treatment, the Pt atoms reduced from Pt4+ in LTA zeolite’s cavities may tend to migrate to the surface and then form nano-particles, which led to the lower H2 evolution efficiency.

  17. Rating curve estimation of nutrient loads in Iowa rivers

    Science.gov (United States)

    Stenback, G.A.; Crumpton, W.G.; Schilling, K.E.; Helmers, M.J.

    2011-01-01

    Accurate estimation of nutrient loads in rivers and streams is critical for many applications including determination of sources of nutrient loads in watersheds, evaluating long-term trends in loads, and estimating loading to downstream waterbodies. Since in many cases nutrient concentrations are measured on a weekly or monthly frequency, there is a need to estimate concentration and loads during periods when no data is available. The objectives of this study were to: (i) document the performance of a multiple regression model to predict loads of nitrate and total phosphorus (TP) in Iowa rivers and streams; (ii) determine whether there is any systematic bias in the load prediction estimates for nitrate and TP; and (iii) evaluate streamflow and concentration factors that could affect the load prediction efficiency. A commonly cited rating curve regression is utilized to estimate riverine nitrate and TP loads for rivers in Iowa with watershed areas ranging from 17.4 to over 34,600km2. Forty-nine nitrate and 44 TP datasets each comprising 5-22years of approximately weekly to monthly concentrations were examined. Three nitrate data sets had sample collection frequencies averaging about three samples per week. The accuracy and precision of annual and long term riverine load prediction was assessed by direct comparison of rating curve load predictions with observed daily loads. Significant positive bias of annual and long term nitrate loads was detected. Long term rating curve nitrate load predictions exceeded observed loads by 25% or more at 33% of the 49 measurement sites. No bias was found for TP load prediction although 15% of the 44 cases either underestimated or overestimate observed long-term loads by more than 25%. The rating curve was found to poorly characterize nitrate and phosphorus variation in some rivers. ?? 2010 .

  18. Mixed-mode stress intensity factors for kink cracks with finite kink length loaded in tension and bending: application to dentin and enamel.

    Science.gov (United States)

    Bechtle, Sabine; Fett, Theo; Rizzi, Gabriele; Habelitz, Stefan; Schneider, Gerold A

    2010-05-01

    Fracture toughness resistance curves describe a material's resistance against crack propagation. These curves are often used to characterize biomaterials like bone, nacre or dentin as these materials commonly exhibit a pronounced increase in fracture toughness with crack extension due to co-acting mechanisms such as crack bridging, crack deflection and microcracking. The knowledge of appropriate stress intensity factors which depend on the sample and crack geometry is essential for determining these curves. For the dental biomaterials enamel and dentin it was observed that, under bending and tensile loading, crack propagation occurs under certain constant angles to the initial notch direction during testing procedures used for fracture resistance curve determination. For this special crack geometry (a kink crack of finite length in a finite body) appropriate geometric function solutions are missing. Hence, we present in this study new mixed-mode stress intensity factors for kink cracks with finite kink length within samples of finite dimensions for two loading cases (tension and bending) which were derived from a combination of mixed-mode stress intensity factors of kink cracks with infinitely small kinks and of slant cracks. These results were further applied to determine the fracture resistance curves of enamel and dentin by testing single edge notched bending (SENB) specimens. It was found that kink cracks with finite kink length exhibit identical stress fields to slant cracks as soon as the kink length exceeds 0.15 times the initial straight crack or notch length. The use of stress intensity factor solutions for infinitely small kink cracks for the determination of dentin fracture resistance curves (as was done by other researchers) leads to an overestimation of dentin's fracture resistance of up to 30%. Copyright 2010 Elsevier Ltd. All rights reserved.

  19. Associations of work-related factors and work engagement with mental and physical health: a 1-year follow-up study among older workers.

    Science.gov (United States)

    Leijten, Fenna R M; van den Heuvel, Swenne G; van der Beek, Allard J; Ybema, Jan Fekke; Robroek, Suzan J W; Burdorf, Alex

    2015-03-01

    The goals of this study were to determine whether, among older employees, unfavourable physical and psychosocial work-related factors were associated with poorer mental and physical health and whether high work engagement buffered the associations between unfavourable work-related factors and poorer health. A 1-year longitudinal study with employed persons aged 45-64 was conducted within the Study on Transitions in Employment, Ability and Motivation (n = 8,837). Using an online questionnaire, work-related factors (physical: physical load; psychosocial: psychological job demands, autonomy, and support) and work engagement were measured at baseline and health at baseline and 1-year follow-up. General linear models were used to assess associations of work-related factors and work engagement with health. Tests of interaction terms assessed whether work engagement buffered the work-related factor-health associations. Unfavourable psychosocial work-related factors at baseline were associated with poorer mental health at follow-up. Higher physical load, higher psychological job demands, and lower autonomy at baseline were associated with poorer physical health at follow-up. Higher work engagement at baseline was related to better physical and especially better mental health during the 1-year follow-up. Work engagement had a small effect on the associations between work-related factors and health. Among older employees, especially the promotion of a high work engagement and, to a lesser extent, favourable work-related factors can be beneficial for mental health in particular.

  20. Calibration procedures for improved accuracy of wind turbine blade load measurement

    Energy Technology Data Exchange (ETDEWEB)

    Dahlberg, J.Aa. [Aeronautical Research Inst. of Sweden, Bromma (Sweden); Johansson, Hjalmar [Teknikgruppen AB, Sollentuna (Sweden)

    1996-12-01

    External loads acting on wind turbine blades are mainly transferred via the hub to the rest of the structure. It is therefore a normal approach to measure the loads acting on the turbine by load measurements in the blade roots. The load measurement is often accomplished by measurements of strain on the surface of the blade or the hub. The strain signals are converted to loads by applying calibration factors to the measurements. This paper deals with difficulties associated with load measurements on two different wind turbines; one with strain gauges applied to a steel hub where a linear stress-load relationship is expected and the other with strain gauges applied to the GFRP blade close to the bearings where strong non-linearity`s and temperature effects are expected. This paper suggests calibration methods to overcome these problems. 2 refs, 11 figs

  1. Mitigating the Long term Operating Extreme Load through Active Control

    International Nuclear Information System (INIS)

    Koukoura, Christina; Natarajan, Anand

    2014-01-01

    The parameters influencing the long term extreme operating design loads are identified through the implementation of a Design of Experiment (DOE) method. A function between the identified critical factors and the ultimate out-of-plane loads on the blade is determined. Variations in the initial blade azimuth location are shown to affect the extreme blade load magnitude during operation in normal turbulence wind input. The simultaneously controlled operation of generator torque variation and pitch variation at low blade pitch angles is detected to be responsible for very high loads acting on the blades. Through gain scheduling of the controller (modifications of the proportional Kp and the integral K gains) the extreme loads are mitigated, ensuring minimum instantaneous variations in the power production for operation above rated wind speed. The response of the blade load is examined for different values of the integral gain as resulting in rotor speed error and the rate of change of rotor speed. Based on the results a new load case for the simulation of extreme loads during normal operation is also presented

  2. Diffusion Indexes With Sparse Loadings

    DEFF Research Database (Denmark)

    Kristensen, Johannes Tang

    2017-01-01

    The use of large-dimensional factor models in forecasting has received much attention in the literature with the consensus being that improvements on forecasts can be achieved when comparing with standard models. However, recent contributions in the literature have demonstrated that care needs...... to the problem by using the least absolute shrinkage and selection operator (LASSO) as a variable selection method to choose between the possible variables and thus obtain sparse loadings from which factors or diffusion indexes can be formed. This allows us to build a more parsimonious factor model...... in forecasting accuracy and thus find it to be an important alternative to PC. Supplementary materials for this article are available online....

  3. Foot positioning instruction, initial vertical load position and lifting technique: effects on low back loading.

    Science.gov (United States)

    Kingma, Idsart; Bosch, Tim; Bruins, Louis; van Dieën, Jaap H

    2004-10-22

    This study investigated the effects of initial load height and foot placement instruction in four lifting techniques: free, stoop (bending the back), squat (bending the knees) and a modified squat technique (bending the knees and rotating them outward). A 2D dynamic linked segment model was combined with an EMG assisted trunk muscle model to quantify kinematics and low back loading in 10 subjects performing 19 different lifting movements, using 10.5 kg boxes without handles. When lifting from a 0.05 m height with the feet behind the box, squat lifting resulted in 19.9% (SD 8.7%) higher net moments (p squat and stoop lifts, as well as the interaction with lifting height, could to a large extent be explained by changes in the horizontal L5/S1 intervertebral joint position relative to the load, the upper body acceleration, and lumbar flexion. Rotating the knees outward during squat lifts resulted in moments and compression forces that were smaller than in squat lifting but larger than in stoop lifting. Shear forces were small ( < 300 N) at the L4/L5 joint and substantial (1100 - 1400 N) but unaffected by lifting technique at the L5/S1 joint. The present results show that the effects of lifting technique on low back loading depend on the task context.

  4. Three Dimensional Parametric Analyses on Effect of Fibre Orientation for Stress Concentration Factor in Fibrous Composite Cantilever Plate with Central Circular Hole under Transverse Loading

    Directory of Open Access Journals (Sweden)

    Nitin Jain

    2012-10-01

    Full Text Available Normal 0 false false false EN-IN X-NONE X-NONE ABSTRACT: A number of analytical and numerical techniques are available for the two dimensional study of stress concentration around the hole(s in isotropic and composite plates subjected to in-plane or transverse loading conditions. The information on the techniques for three dimensional analyses of stress concentration factor (SCF around the hole in isotropic and composite plates subjected to transverse loading conditions is, however, limited. The present work emphasizes on the effect of fibre orientation (q on the stress concentration factor in fibrous composite plates with central circular hole under transverse static loading condition. The work is carried out for cantilever fibrous composite plates. The effects of thickness -to- width (T/A and diameter-to-width (D/A ratios upon SCF at different fibre orientation are studied. Plates of four different composite materials were considered for hole analysis in order to determine the sensitivity of SCF with elastic constants. Deflections in transverse direction were calculated and analysed. All results are presented in graphical form and discussed. The finite element formulation and its analysis were carried out using ANSYS package.ABSTRAK: Terdapat pelbagai teknik analitikal dan numerical untuk kajian tumpuan tegasan dua dimensi di sekeliling lubang-lubang dalam komposit isotropik dan plat pada satah atau keadaan bebanan melintang. Bagaimanapun, maklumat mengenai kaedah analisis tiga dimensi untuk faktor ketumpatan tegasan (SCF sekitar lubang dalam komposit isotropik dan plat pada keadaan bebanan melintang adalah terhad. Kertas ini menekankan kesan orientasi gentian (q pada faktor tumpuan tegasan dalam komposit plat bergentian dengan lubang berpusat di bawah keadaan bebanan melintang. Kajian ini dilkukan untuk cantilever plat komposit bergentian. Kesan ketebalan terhadap kelebaran plat (T/A dan diameter terhadap kelebaran komposit (D/A dengan SCF

  5. Cognitive task load in a naval ship control centre: from identification to prediction.

    Science.gov (United States)

    Grootjen, M; Neerincx, M A; Veltman, J A

    Deployment of information and communication technology will lead to further automation of control centre tasks and an increasing amount of information to be processed. A method for establishing adequate levels of cognitive task load for the operators in such complex environments has been developed. It is based on a model distinguishing three load factors: time occupied, task-set switching, and level of information processing. Application of the method resulted in eight scenarios for eight extremes of task load (i.e. low and high values for each load factor). These scenarios were performed by 13 teams in a high-fidelity control centre simulator of the Royal Netherlands Navy. The results show that the method provides good prediction of the task load that will actually appear in the simulator. The model allowed identification of under- and overload situations showing negative effects on operator performance corresponding to controlled experiments in a less realistic task environment. Tools proposed to keep the operator at an optimum task load are (adaptive) task allocation and interface support.

  6. Estimating total maximum daily loads with the Stochastic Empirical Loading and Dilution Model

    Science.gov (United States)

    Granato, Gregory; Jones, Susan Cheung

    2017-01-01

    The Massachusetts Department of Transportation (DOT) and the Rhode Island DOT are assessing and addressing roadway contributions to total maximum daily loads (TMDLs). Example analyses for total nitrogen, total phosphorus, suspended sediment, and total zinc in highway runoff were done by the U.S. Geological Survey in cooperation with FHWA to simulate long-term annual loads for TMDL analyses with the stochastic empirical loading and dilution model known as SELDM. Concentration statistics from 19 highway runoff monitoring sites in Massachusetts were used with precipitation statistics from 11 long-term monitoring sites to simulate long-term pavement yields (loads per unit area). Highway sites were stratified by traffic volume or surrounding land use to calculate concentration statistics for rural roads, low-volume highways, high-volume highways, and ultraurban highways. The median of the event mean concentration statistics in each traffic volume category was used to simulate annual yields from pavement for a 29- or 30-year period. Long-term average yields for total nitrogen, phosphorus, and zinc from rural roads are lower than yields from the other categories, but yields of sediment are higher than for the low-volume highways. The average yields of the selected water quality constituents from high-volume highways are 1.35 to 2.52 times the associated yields from low-volume highways. The average yields of the selected constituents from ultraurban highways are 1.52 to 3.46 times the associated yields from high-volume highways. Example simulations indicate that both concentration reduction and flow reduction by structural best management practices are crucial for reducing runoff yields.

  7. Shouldering the load: A review of Joan Stevenson's work on occupational lifting and design evaluation of load carriage equipment.

    Science.gov (United States)

    Costigan, Patrick A; Morin, Evelyn L; Reid, Susan A

    2014-01-01

    In this paper, Dr. Joan Stevenson's work on assessment of the effects of lifting, supporting and transporting loads is reviewed. A defining attribute of this work is the use of objective, biomechanical measures as the basis from which a fuller understanding of all factors affecting worker performance can be obtained, and how such performance should be measured and evaluated. The central objectives and conclusions of Dr. Stevenson's research programs spanning the years from 1985 through 2012 are summarized and discussed in terms of an overall research trajectory. The guiding principle of Dr. Stevenson's work is to reduce the potential harm to which workers are exposed through the development of bona fide occupational standards, a better understanding of risk factors leading to low back pain, and the establishment of an enhanced objective design process for functional load-bearing clothing and equipment.

  8. Drug loaded biodegradable load-bearing nanocomposites for damaged bone repair

    Science.gov (United States)

    Gutmanas, E. Y.; Gotman, I.; Sharipova, A.; Psakhie, S. G.; Swain, S. K.; Unger, R.

    2017-09-01

    In this paper we present a short review-scientific report on processing and properties, including in vitro degradation, of load bearing biodegradable nanocomposites as well as of macroporous 3D scaffolds for bone ingrowth. Biodegradable implantable devices should slowly degrade over time and disappear with ingrown of natural bone replacing the synthetic graft. Compared to low strength biodegradable polymers, and brittle CaP ceramics, biodegradable CaP-polymer and CaP-metal nanocomposites, mimicking structure of natural bone, as well as strong and ductile metal nanocomposites can provide to implantable devices both strengths and toughness. Nanostructuring of biodegradable β-TCP (tricalcium phosphate)-polymer (PCL and PLA), β-TCP-metal (FeMg and FeAg) and of Fe-Ag composites was achieved employing high energy attrition milling of powder blends. Nanocomposite powders were consolidated to densities close to theoretical by high pressure consolidation at ambient temperature—cold sintering, with retention of nanoscale structure. The strength of developed nanocomposites was significantly higher as compared with microscale composites of the same or similar composition. Heat treatment at moderate temperatures in hydrogen flow resulted in retention of nanoscale structure and higher ductility. Degradation of developed biodegradable β-TCP-polymer, β-TCP-metal and of Fe-Ag nanocomposites was studied in physiological solutions. Immersion tests in Ringer's and saline solution for 4 weeks resulted in 4 to 10% weight loss and less than 50% decrease in compression or bending strength, the remaining strength being significantly higher than the values reported for other biodegradable materials. Nanostructuring of Fe-Ag based materials resulted also in an increase of degradation rate because of creation on galvanic Fe-Ag nanocouples. In cell culture experiments, the developed nanocomposites supported the attachment the human osteoblast cells and exhibited no signs of cytotoxicity

  9. Further insights on the French WISC-IV factor structure through Bayesian structural equation modeling.

    Science.gov (United States)

    Golay, Philippe; Reverte, Isabelle; Rossier, Jérôme; Favez, Nicolas; Lecerf, Thierry

    2013-06-01

    The interpretation of the Wechsler Intelligence Scale for Children--Fourth Edition (WISC-IV) is based on a 4-factor model, which is only partially compatible with the mainstream Cattell-Horn-Carroll (CHC) model of intelligence measurement. The structure of cognitive batteries is frequently analyzed via exploratory factor analysis and/or confirmatory factor analysis. With classical confirmatory factor analysis, almost all cross-loadings between latent variables and measures are fixed to zero in order to allow the model to be identified. However, inappropriate zero cross-loadings can contribute to poor model fit, distorted factors, and biased factor correlations; most important, they do not necessarily faithfully reflect theory. To deal with these methodological and theoretical limitations, we used a new statistical approach, Bayesian structural equation modeling (BSEM), among a sample of 249 French-speaking Swiss children (8-12 years). With BSEM, zero-fixed cross-loadings between latent variables and measures are replaced by approximate zeros, based on informative, small-variance priors. Results indicated that a direct hierarchical CHC-based model with 5 factors plus a general intelligence factor better represented the structure of the WISC-IV than did the 4-factor structure and the higher order models. Because a direct hierarchical CHC model was more adequate, it was concluded that the general factor should be considered as a breadth rather than a superordinate factor. Because it was possible for us to estimate the influence of each of the latent variables on the 15 subtest scores, BSEM allowed improvement of the understanding of the structure of intelligence tests and the clinical interpretation of the subtest scores. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  10. SORM correction of FORM results for the FBC load combination problem

    DEFF Research Database (Denmark)

    Ditlevsen, Ove

    2005-01-01

    The old stochastic load combination model of Ferry Borges and Castanheta and the corresponding extreme random load effect value is considered. The evaluation of the distribution function of the extreme value by use of a particular first order reliability method was first described in a celebrated...... calculations. The calculation gives a limit state curvature correction factor on the probability approximation obtained by the RF algorithm. This correction factor is based on Breitung’s celebrated asymptotic formula. Example calculations with comparisons with exact results show an impressing accuracy...

  11. Plastic limit loads for cylindrical shell intersections under combined loading

    International Nuclear Information System (INIS)

    Skopinsky, V.N.; Berkov, N.A.; Vogov, R.A.

    2015-01-01

    In this research, applied methods of nonlinear analysis and results of determining the plastic limit loads for shell intersection configurations under combined internal pressure, in-plane moment and out-plane moment loadings are presented. The numerical analysis of shell intersections is performed using the finite element method, geometrically nonlinear shell theory in quadratic approximation and plasticity theory. For determining the load parameter of proportional combined loading, the developed maximum criterion of rate of change of relative plastic work is employed. The graphical results for model of cylindrical shell intersection under different two-parameter combined loadings (as generalized plastic limit load curves) and three-parameter combined loading (as generalized plastic limit load surface) are presented on the assumption that the internal pressure, in-plane moment and out-plane moment loads were applied in a proportional manner. - Highlights: • This paper presents nonlinear two-dimensional FE analysis for shell intersections. • Determining the plastic limit loads under combined loading is considered. • Developed maximum criterion of rate of change of relative plastic work is employed. • Plastic deformation mechanism in shell intersections is discussed. • Results for generalized plastic limit load curves of branch intersection are presented

  12. A nanoparticulate injectable hydrogel as a tissue engineering scaffold for multiple growth factor delivery for bone regeneration

    Directory of Open Access Journals (Sweden)

    Dyondi D

    2012-12-01

    Full Text Available Deepti Dyondi,1 Thomas J Webster,2 Rinti Banerjee11Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India; 2Nanomedicine Laboratories, Division of Engineering and Department of Orthopedics, Brown University, Providence, RI, USAAbstract: Gellan xanthan gels have been shown to be excellent carriers for growth factors and as matrices for several tissue engineering applications. Gellan xanthan gels along with chitosan nanoparticles of 297 ± 61 nm diameter, basic fibroblast growth factor (bFGF, and bone morphogenetic protein 7 (BMP7 were employed in a dual growth factor delivery system to promote the differentiation of human fetal osteoblasts. An injectable system with ionic and temperature gelation was optimized and characterized. The nanoparticle loaded gels showed significantly improved cell proliferation and differentiation due to the sustained release of growth factors. A differentiation marker study was conducted, analyzed, and compared to understand the effect of single vs dual growth factors and free vs encapsulated growth factors. Dual growth factor loaded gels showed a higher alkaline phosphatase and calcium deposition compared to single growth factor loaded gels. The results suggest that encapsulation and stabilization of growth factors within nanoparticles and gels are promising for bone regeneration. Gellan xanthan gels also showed antibacterial effects against Pseudomonas aeruginosa, Staphylococcus aureus, and Staphylococcus epidermidis, the common pathogens in implant failure.Keywords: bone tissue engineering, bone morphogenetic protein 7 (BMP7, basic fibroblast growth factor (bFGF, hydrogel, nanoparticles, osteoblasts

  13. Calculation of piping loads due to filling procedures

    International Nuclear Information System (INIS)

    Swidersky, Harald; Thiele, Thomas

    2012-01-01

    Filling procedures in piping systems are usually not load cases that are studied by fluid dynamic and structure dynamic analyses with respect to the integrity of pipes and supports. Although, their frequency is higher than that of postulated accidental transients, therefore they have to be considered for fatigue analyses. The piping and support loads due to filling procedures are caused by the density differences if the transported fluids, for instance in flows with the transport of gas bubbles. The impact duration of the momentum forces is defined by the flow velocity and the length of discontinuities in the piping segments. Filling procedures end very often with a shock pressure, caused by the impact and decelerating of the fluid front at smaller cross sections. The suitability of the thermally hydraulics program RELAP/MOD3.3 for the calculation of realistic loads from filling procedures was studied, the results compared with experimental data. It is shown that dependent on the discretization level the loads are partial significantly underestimated.

  14. Investigation of Redistribution of Pile Foundation Forces Under Successive Loading of Its Elements

    Science.gov (United States)

    Sedin, Vladimir; Bikus, Kateryna; Kovba, Vladislav

    2017-12-01

    Redistribution of pile foundation forces under successive loading of its elements was investigated under laboratory conditions. A segment of pile foundation model was taken for use in the case study. Load tests on the pile foundation model segment, without joining its elements (pile and plate, which turns into grillage) and based on different combinations of static loadings were conducted. This proved that the loading of a plate causes skin friction on some length of the pile side surface as well as providing additional loading and settlement. Test results have shown that application of successive elements enables the foundation to carry loads up to 13% higher than in the case of a standard pile foundation loading with the same settlement rates.

  15. Differences in the association between psychosocial work conditions and physical work load in female- and male-dominated occupations. MUSIC-Norrtälje Study Group.

    Science.gov (United States)

    Josephson, M; Pernold, G; Ahlberg-Hultén, G; Härenstam, A; Theorell, T; Vingård, E; Waldenström, M; Hjelm, E W

    1999-01-01

    This study investigated whether there is a relationship between high physical work load and adverse psychosocial work factors, and whether this relationship is different for women and men. Separate analyses for female registered nurses and assistant nurses were made because these are common occupations involving high physical and psychological demands. This study was part of the MUSIC-Norrtälje study, a population study with the overall aim of identifying risk factors for musculoskeletal disorders. The respondents, 1423 gainfully employed men and women, were randomly selected from the study population. The exposure assessments referred to a typical workday during the previous 12 months. Physical exposure was investigated by interview, psychosocial work factors by interview and questionnaire. For the women, but not the men, mainly routine work and a job strain situation, according to the model of Karasek and Theorell, increased the probability of having a high physical work load, assessed as a time-weighted average of energy expenditure in multiples of the resting metabolic rate. Results indicated that in female-dominated occupations, high physical work load might also imply adverse psychosocial conditions. A higher frequency of high physical work load and job strain was observed among assistant nurses compared with registered nurses. Covariance between physical and psychosocial demands makes it difficult to determine the relative influence of each in health problems. Results of the present study imply that this is a larger problem in studies of women than men.

  16. The effect of COD loading on the granule-based enhanced biological phosphorus removal system and the recoverability.

    Science.gov (United States)

    Yu, Shenjing; Sun, Peide; Zheng, Wei; Chen, Lujun; Zheng, Xiongliu; Han, Jingyi; Yan, Tao

    2014-11-01

    In this study, the effect of varied COD loading (200, 400, 500, 600 and 800 mg L(-1)) on stability and recoverability of granule-based enhanced biological phosphorus removal (EBPR) system was investigated during continuously 53-d operation. Results showed that COD loading higher than 500 mg L(-1) could obviously deteriorate the granular EBPR system and result in sludge bulking with filamentous bacteria. High COD loading also changed the transformation patterns of poly-β-hydroxyalkanoates (PHAs) and glycogen in metabolism process of polyphosphate-accumulating organisms (PAOs) and inhibited the EPS secretion, which completely destroyed the stability and integrality of granules. Results of FISH indicated that glycogen-accumulating organisms (GAOs) and other microorganisms had a competitive advantage over PAOs with higher COD loading. The community composition and EBPR performance were recovered irreversibly in long time operation when COD loading was higher than 500 mg L(-1). Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Cognitive load imposed by ultrasound-facilitated teaching does not adversely affect gross anatomy learning outcomes.

    Science.gov (United States)

    Jamniczky, Heather A; Cotton, Darrel; Paget, Michael; Ramji, Qahir; Lenz, Ryan; McLaughlin, Kevin; Coderre, Sylvain; Ma, Irene W Y

    2017-03-01

    Ultrasonography is increasingly used in medical education, but its impact on learning outcomes is unclear. Adding ultrasound may facilitate learning, but may also potentially overwhelm novice learners. Based upon the framework of cognitive load theory, this study seeks to evaluate the relationship between cognitive load associated with using ultrasound and learning outcomes. The use of ultrasound was hypothesized to facilitate learning in anatomy for 161 novice first-year medical students. Using linear regression analyses, the relationship between reported cognitive load on using ultrasound and learning outcomes as measured by anatomy laboratory examination scores four weeks after ultrasound-guided anatomy training was evaluated in consenting students. Second anatomy examination scores of students who were taught anatomy with ultrasound were compared with historical controls (those not taught with ultrasound). Ultrasound's perceived utility for learning was measured on a five-point scale. Cognitive load on using ultrasound was measured on a nine-point scale. Primary outcome was the laboratory examination score (60 questions). Learners found ultrasound useful for learning. Weighted factor score on "image interpretation" was negatively, but insignificantly, associated with examination scores [F (1,135) = 0.28, beta = -0.22; P = 0.61]. Weighted factor score on "basic knobology" was positively and insignificantly associated with scores; [F (1,138) = 0.27, beta = 0.42; P = 0.60]. Cohorts exposed to ultrasound had significantly higher scores than historical controls (82.4% ± SD 8.6% vs. 78.8% ± 8.5%, Cohen's d = 0.41, P learning and may improve learning outcomes. Anat Sci Educ 10: 144-151. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  18. Training Load, Immune Status, and Clinical Outcomes in Young Athletes: A Controlled, Prospective, Longitudinal Study

    Science.gov (United States)

    Blume, Katharina; Körber, Nina; Hoffmann, Dieter; Wolfarth, Bernd

    2018-01-01

    Introduction: Beside positive effects on athlete's health, competitive sport can be linked with an increased risk of illness and injury. Because of high relative increases in training, additional physical and psychological strains, and an earlier specialization and professionalization, adolescent athletes needs an increased attention. Training can alter the immune system by inducing a temporary immunosuppression, finally developing infection symptoms. Previous studies identified Epstein Barr Virus (EBV) as potential indicator for the immune status. In addition to the identification of triggering risk factors for recurrent infections, the aim was to determine the interaction between training load, stress sense, immunological parameters, and clinical symptoms. Methods: A controlled, prospective, longitudinal study on young athletes (n = 274, mean age: 13.8 ± 1.5 yrs) was conducted between 2010 and 2014. Also 285 controls (students, who did not perform competitive sports, mean age: 14.5 ± 1.9 yrs) were recruited. Athletes were examined 3 times each year to determine the effects of stress factors (training load: training hours per week [Th/w]) on selected outcome parameters (clinical [susceptibility to infection, WURSS-21: 21-item Wisconsin Upper Respiratory Symptom Survey], immunological, psychological end points). As part of each visit, EBV serostatus and EBV-specific IgG tiers were studied longitudinally as potential immune markers. Results: Athletes (A) trained 14.9 ± 5.6 h weekly. Controls (C) showed no lower stress levels compared to athletes (p = 0.387). Twelve percent of athletes reported recurrent infections (C: 8.5%, p = 0.153), the presence of an upper respiratory tract infection (URTI) was achieved in 30.7%. EBV seroprevalence of athletes was 60.3% (C: 56.6%, p = 0.339). Mean EBV-specific IgG titer of athletes was 166 ± 115 U/ml (C: 137 ± 112 U/ml, p = 0.030). With increasing Th/w, higher stress levels were observed (p athletes showed no increased

  19. Toward Digital Citizenship: Examining Factors Affecting Participation and Involvement in the Internet Society among Higher Education Students

    Science.gov (United States)

    Al-Zahrani, Abdulrahman

    2015-01-01

    The current study aims to understand digital citizenship, based on the assumptions of Ribble (2014), by examining factors affecting participation and involvement in the Internet virtual societies among higher education students. A quantitative approach using a survey questionnaire was implemented. The participants were 174 students from the…

  20. A model for damage load and its implications for the evolution of bacterial aging.

    Directory of Open Access Journals (Sweden)

    Lin Chao

    2010-08-01

    Full Text Available Deleterious mutations appearing in a population increase in frequency until stopped by natural selection. The ensuing equilibrium creates a stable frequency of deleterious mutations or the mutational load. Here I develop the comparable concept of a damage load, which is caused by harmful non-heritable changes to the phenotype. A damage load also ensues when the increase of damage is opposed by selection. The presence of a damage load favors the evolution of asymmetrical transmission of damage by a mother to her daughters. The asymmetry is beneficial because it increases fitness variance, but it also leads to aging or senescence. A mathematical model based on microbes reveals that a cell lineage dividing symmetrically is immortal if lifetime damage rates do not exceed a threshold. The evolution of asymmetry allows the lineage to persist above the threshold, but the lineage becomes mortal. In microbes with low genomic mutation rates, it is likely that the damage load is much greater than the mutational load. In metazoans with higher genomic mutation rates, the damage and the mutational load could be of the same magnitude. A fit of the model to experimental data shows that Escherichia coli cells experience a damage rate that is below the threshold and are immortal under the conditions examined. The model estimates the asymmetry level of E. coli to be low but sufficient for persisting at higher damage rates. The model also predicts that increasing asymmetry results in diminishing fitness returns, which may explain why the bacterium has not evolved higher asymmetry.