WorldWideScience

Sample records for higher fracture resistance

  1. Fracture resistance curves and toughening mechanisms in polymer based dental composites

    DEFF Research Database (Denmark)

    De Souza, J.A.; Goutianos, Stergios; Skovgaard, M.

    2011-01-01

    The fracture resistance (R-curve behaviour) of two commercial dental composites (Filtek Z350® and Concept Advanced®) were studied using Double Cantilever Beam sandwich specimens loaded with pure bending moments to obtain stable crack growth. The experiments were conducted in an environmental...... significantly higher fracture resistance than the composite with the coarser microstructure. The fracture properties were related to the flexural strength of the dental composites. The method, thus, can provide useful insight into how the microstructure enhances toughness, which is necessary for the future...

  2. Diffusivity and electrical resistivity measurements in rock matrix around fractures

    International Nuclear Information System (INIS)

    Kumpulainen, H.; Uusheimo, K.

    1989-12-01

    Microfracturing of rock matrix around permeable fractures was studied experimentally from drill core samples around major fractures. The methods used were diffusion measurements using a 36 Cl-tracer and electrical resistivity measurements. Rock samples were from the Romuvaara investigation site, the granite specimen around a partially filled carbonate fracture (KR4/333 m) and gneiss specimen around a slickenside fracture (KR1/645 m). A consistent difference of one to two orders of magnitude in the levels of the methods with regard to the effective diffusion coefficients for Cl - -ion was found, the electrical resistivity measurement giving higher values. On the basis of the diffusion measurements the diffusion porosities could be calculated but these remained one to two orders of magnitude lower than that expected for granitic rocks using the water saturation method. A possible reason for these differences could have been the low, in some cases 0.004 M NaC1-concentration in the diffusion experiments vs. the 1 M NaCl-concentration used in the electrical resistivity measurements. Due to the small number of specimens and cross sectional areas of only 2 cm 2 , rock inhomogeneity effects were significant making the interpretation of the results somewhat troublesome. Porosities on fracture surfaces seemed to be higher than in the deeper, more intact rock matrix

  3. In vitro fracture resistance of three commercially available zirconia crowns for primary molars.

    Science.gov (United States)

    Townsend, Janice A; Knoell, Patrick; Yu, Qingzhao; Zhang, Jian-Feng; Wang, Yapin; Zhu, Han; Beattie, Sean; Xu, Xiaoming

    2014-01-01

    The purpose of this study was to measure the fracture resistance of primary mandibular first molar zirconia crowns from three different manufacturers-EZ Pedo (EZP), NuSmile (NSZ), and Kinder Krowns (KK)-and compare it with the thickness of the zirconia crowns and the measured fracture resistance of preveneered stainless steel crowns (SSCs). The thickness of 20 zirconia crowns from three manufacturers were measured. The mean force required to fracture the crowns was determined. Preveneered NuSmile (NSW) SSCs were tested as a control. EZP crowns were significantly thicker in three of the six measured locations. The force required to fracture the EZP crown was significantly higher than that required for NSZ and KK. There was a positive correlation between fracture resistance and crown thickness in the mesial, distal, mesioocclusal, and distoocclusal dimensions. None of the zirconia crowns proved to be as resistant to fracture as the preveneered SSCs. Statistically significant differences were found among the forces required to fracture zirconia crowns by three different manufacturers. The increase in force correlated with crown thickness. The forces required to fracture the preveneered stainless steel crowns were greater than the forces required to fracture all manufacturers' zirconia crowns.

  4. Small-scale electrical resistivity tomography of wet fractured rocks.

    Science.gov (United States)

    LaBrecque, Douglas J; Sharpe, Roger; Wood, Thomas; Heath, Gail

    2004-01-01

    This paper describes a series of experiments that tested the ability of the electrical resistivity tomography (ERT) method to locate correctly wet and dry fractures in a meso-scale model. The goal was to develop a method of monitoring the flow of water through a fractured rock matrix. The model was a four by six array of limestone blocks equipped with 28 stainless steel electrodes. Dry fractures were created by placing pieces of vinyl between one or more blocks. Wet fractures were created by injecting tap water into a joint between blocks. In electrical terms, the dry fractures are resistive and the wet fractures are conductive. The quantities measured by the ERT system are current and voltage around the outside edge of the model. The raw ERT data were translated to resistivity values inside the model using a three-dimensional Occam's inversion routine. This routine was one of the key components of ERT being tested. The model presented several challenges. First, the resistivity of both the blocks and the joints was highly variable. Second, the resistive targets introduced extreme changes the software could not precisely quantify. Third, the abrupt changes inherent in a fracture system were contrary to the smoothly varying changes expected by the Occam's inversion routine. Fourth, the response of the conductive fractures was small compared to the background variability. In general, ERT was able to locate correctly resistive fractures. Problems occurred, however, when the resistive fracture was near the edges of the model or when multiple fractures were close together. In particular, ERT tended to position the fracture closer to the model center than its true location. Conductive fractures yielded much smaller responses than the resistive case. A difference-inversion method was able to correctly locate these targets.

  5. Characterizing Fracture Property Using Resistivity Measured at Different Frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Horne, Roland N. [Stanford Univ., CA (United States); Li, Kewen [Stanford Univ., CA (United States)

    2014-09-30

    The objective was to develop geophysical approaches to detecting and evaluating the fractures created or existing in EGS and other geothermal reservoirs by measuring the resistivity at different frequencies. This project has been divided into two phases: Phase I (first year): Proof of Concept – develop the resistivity approach and verify the effect of frequency on the resistivity in rocks with artificial or natural fractures over a wide range of frequencies. Phase II: Prototyping Part 1 (second year): measure the resistivity in rocks with fractures of different apertures, different length, and different configurations at different frequencies. Part 2 (third year): develop mathematical models and the resistivity method; infer the fracture properties using the measured resistivity data.

  6. Fracture-resistant monolithic dental crowns.

    Science.gov (United States)

    Zhang, Yu; Mai, Zhisong; Barani, Amir; Bush, Mark; Lawn, Brian

    2016-03-01

    To quantify the splitting resistance of monolithic zirconia, lithium disilicate and nanoparticle-composite dental crowns. Fracture experiments were conducted on anatomically-correct monolithic crown structures cemented to standard dental composite dies, by axial loading of a hard sphere placed between the cusps. The structures were observed in situ during fracture testing, and critical loads to split the structures were measured. Extended finite element modeling (XFEM), with provision for step-by-step extension of embedded cracks, was employed to simulate full failure evolution. Experimental measurements and XFEM predictions were self-consistent within data scatter. In conjunction with a fracture mechanics equation for critical splitting load, the data were used to predict load-sustaining capacity for crowns on actual dentin substrates and for loading with a sphere of different size. Stages of crack propagation within the crown and support substrate were quantified. Zirconia crowns showed the highest fracture loads, lithium disilicate intermediate, and dental nanocomposite lowest. Dental nanocomposite crowns have comparable fracture resistance to natural enamel. The results confirm that monolithic crowns are able to sustain high bite forces. The analysis indicates what material and geometrical properties are important in optimizing crown performance and longevity. Copyright © 2015 Academy of Dental Materials. All rights reserved.

  7. Effect of amalgam cuspal coverage on the fracture resistance of endodontically treated teeth

    Directory of Open Access Journals (Sweden)

    Mahshid Mohammdi Basir

    2013-05-01

    Full Text Available   Background and Aims: Endodontically treated teeth are prone to fracture because they loose a big amount of their structure. The treatment plan of those teeth is completed when they are rehabilitated with a strong and functional restoration. The purpose of this study was to evaluate the fracture resistance of endodontically treated teeth restored with amalgam cuspal coverage in comparison with other restorative techniques.   Materials and Methods: 40 human healthy maxillary premolars were divided into 4 groups: group1 (S: sound teeth, group 2(Co: endodontically treated teeth with MOD cavity restored with bonding and composite, group 3(Am-B: endodontically treated teeth with MOD cavity restored with bonding and amalgam and group 4 (Am-CC: endodontically treated teeth with MOD cavity restored with amalgam cuspal coverage. Then the restorations were stored in water and room temperature for 100 days at then thermocycled for 500 cycles between water baths at (5.5 ± 1 and (55 ± 1 0 C. The fracture resistance was evaluated by universal testing machine (Instron, 1195 UK with the compressive force of about 2000 N in 0.5 mm/min. The fracture modes were evaluated in four groups by a stereomicroscope. Statistical analysis (Scheffe test was done for all groups (P0.05. The lowest fracture resistance was found in group 2 (Co (384 ± 137.4 N that had no significant difference with group 3 (Am-B (P>0.05. The fracture resistance in group 4 was significantly higher than group 2 (Co and 3 (Am-B. The fracture mode in group 1 was cohesive within tooth and in group 2 (Co and 3 (Am-B was mixed cohesive and adhesive, and in group 4 was cohesive within in restorative material.   Conclusion: The highest fracture resistance was found in teeth that received amalgam cuspal coverage.

  8. Fracture Resistance and Failure Mode of Endodontically Treated Premolars Restored with Different Adhesive Restorations

    Directory of Open Access Journals (Sweden)

    Nasrin Sarabi

    2015-03-01

    Full Text Available Introduction: The restoration of endodontically treated teeth is a topic that has been studied extensively but it is still a challenge for dental practitioners. The aim of this study was to evaluate fracture resistance, fracture patterns and fracture location of endodontically treated human maxillary premolars restored with direct and indirect composite resin and ceramic restoration. Methods: Eighty non-carious maxillary premolars were selected and divided into four groups (n=20. Endodontic treatment and mesio-occluso-distal preparations were carried out in all the groups except for the control group (group I. Subsequently, the prepared teeth were restored as follows: group II: indirect composite restoration; group III: ceramic restoration; group IV: direct composite restoration. The specimens were subjected to compressive axial loading until fracture occurred. The mode of failure was also recorded. Results: Group I had higher fracture resistance (1196.82±241.74 than the other groups (P

  9. Fracture resistance of asphalt concrete modified with crumb rubber at low temperatures

    Directory of Open Access Journals (Sweden)

    A. Razmi

    2018-05-01

    Full Text Available The main objective of this study is to obtain fracture toughness of asphalt concrete modified by Crumb Rubber (CR and Sasobit at low temperatures. First, Bending Beam Rheometer (BBR test was performed on unmodified binder (binder 60/70, binder 60/70 + 3%Sasobit and 20%CR + 3%Sasobit modified asphalt binder to find how each modifier affect asphalt binder stiffness and relaxation rate at low temperatures. Mixed mode I/II fracture tests were conducted by cracked Semi-Circular Bending (SCB specimens and the critical stress intensity factors were calculated for pure mode I, mixed mode I/II and pure mode II conditions. Results of BBR tests indicated that 20%CR + 3%Sasobit reduces stiffness and the m-value increase at low temperatures. As a result, 20%CR + 3%Sasobit has positive effect on low temperatures performance by improving thermal cracking resistance. Also, according to the fracture toughness test results, the Warm Mix Asphalt (WMA mixture containing 20% CR, shows higher resistance against crack growth than WMA mixture. It was found that mixed mode I/II can be more detrimental than pure mode I and II conditions. Keywords: Crumb rubber, Asphalt concrete, Bending Beam Rheometer, Fracture resistance, Semi-circular bending test

  10. Fracture resistance of aluminium oxide and lithium disilicate-based crowns using different luting cements: an in vitro study.

    Science.gov (United States)

    Al-Wahadni, Ahed M; Hussey, David L; Grey, Nicholas; Hatamleh, Muhanad M

    2009-03-01

    The aim of this study was to investigate the fracture resistance of two types of ceramic crowns cemented with two different cements. Forty premolar crowns were fabricated using lithium-disilicate (IPS Empress-2) and glass-infiltrated aluminium-oxide (In-Ceram) ceramic systems. The crowns were divided into four groups (n=10) with Group 1 (IPS Empress-2) and Group 2 (In-Ceram) cemented with glass ionomer cement. Group 3 (IPS Empress-2) and Group 4 (In-Ceram) were cemented with resin cement. Crowns were tested in a universal testing machine at a compressive-load speed of 10 mm/min. Fracture modes were grouped into five categories. One way analysis of variance (ANOVA) and Bonferroni post-hoc tests were used to detect statistical significances (p0.05) on fracture resistance within each ceramic system tested. In-Ceram crowns cemented with either glass ionomer or resin cements exhibited a statistically significantly higher fracture-resistance than IPS Empress-2 crowns (pEmpress-2 and In-Ceram crowns was not affected by the type of cement used for luting. Both In-Ceram and IPS Empress-2 crowns can be successfully luted with the cements tested with In-Ceram exhibiting higher fracture resistance than IPS Empress-2.

  11. Fracture resistance enhancement of layered structures by multiple cracks

    DEFF Research Database (Denmark)

    Goutianos, Stergios; Sørensen, Bent F.

    2016-01-01

    A theoretical model is developed to test if the fracture resistance of a layered structure can be increased by introducing weak layers changing the cracking mechanism. An analytical model, based on the J integral, predicts a linear dependency between the number of cracks and the steady state...... fracture resistance. A finite element cohesive zone model, containing two cracking planes for simplicity, is used to check the theoretical model and its predictions. It is shown that for a wide range of cohesive law parameters, the numerical predictions agree well quantitatively with the theoretical model....... Thus, it is possible to enhance considerably the fracture resistance of a structure by adding weak layers....

  12. Fracture Resistance of Pulpotomized Primary Molar Restored with Extensive Class II Amalgam Restorations

    Directory of Open Access Journals (Sweden)

    F. Mazhari

    2008-06-01

    Full Text Available Objective: The aim of the present study was to evaluate fracture resistance of pulpoto-mized primary molar teeth restored with extensive multisurface amalgam restorations.Materials and Methods: Eighty extracted carious human primary molar teeth were se-lected forpresent study. Teeth were divided in to eight groups of ten. Mesio- or disto-occlusal and Mesio-occluso-distal cavities with different cavity wall thickness (1.5 or 2.5mm were prepared in both first and second primary molar teeth. After restoring teeth with amalgam, all specimens were stored in distilled water at 37°C for 7 days. Then samples were thermocycled for 1000 cycles from 5°C to 55°C. The specimens then were subjected to a compressive load in a universal testing machine at a crosshead speed of 0.5 mm min-1. ANOVA and t-test were used for statistical analysis.Results: Mean fracture resistance of first and second molar teeth were 975.5 N (SD=368.8 and 1049.2 N (SD=540.1 respectively. In the first molar group, fracture resis-tance of two-surface cavities was significantly more than three-surface cavities (P<0.001, however this difference was not statistically significant in the second molar group. In both first and second molar group, fracture resistance incavities with 2.5 mm wall thickness, was significantly more than the group with 1.5 mm wall thickness.Conclusion: The mean fracture resistance in pulpotomized primary molar restored with amalgam restorations was higher than reported maximum bite force in primary teeth even in extensive multi-surface restorations. Therefore, the teeth with large proximal carious lesions in schoolchildren could be restored with amalgam.

  13. Influence of ceramic thickness and ceramic materials on fracture resistance of posterior partial coverage restorations.

    Science.gov (United States)

    Bakeman, E M; Rego, N; Chaiyabutr, Y; Kois, J C

    2015-01-01

    This study evaluated the influence of ceramic thickness and ceramic materials on fracture resistance of posterior partial coverage ceramic restorations. Forty extracted molars were allocated into four groups (n=10) to test for two variables: 1) the thickness of ceramic (1 mm or 2 mm) and 2) the ceramic materials (a lithium disilicate glass-ceramic [IPS e.max] or leucite-reinforced glass ceramic [IPS Empress]). All ceramic restorations were luted with resin cement (Variolink II) on the prepared teeth. These luted specimens were loaded to failure in a universal testing machine, in the compression mode, with a crosshead speed of 1.0 mm/min. The data were analyzed using two-way analysis of variance and the Tukey Honestly Significantly Different multiple comparison test (α =0.05). The fracture resistance revealed a significant effect for materials (pceramic was not significant (p=0.074), and the interaction between the thickness of ceramic and the materials was not significant (p=0.406). Mean (standard deviation) fracture resistance values were as follows: a 2-mm thickness of a lithium disilicate bonded to tooth structure (2505 [401] N) revealed a significantly higher fracture resistance than did a 1-mm thickness of leucite-reinforced (1569 [452] N) and a 2-mm thickness of leucite-reinforced ceramic bonded to tooth structure (1716 [436] N) (pceramic at 1-mm thickness (2105 [567] N) and at 2-mm thickness. Using a lithium disilicate glass ceramic for partial coverage restoration significantly improved fracture resistance compared to using a leucite-reinforced glass ceramic. The thickness of ceramic had no significant effect on fracture resistance when the ceramics were bonded to the underlying tooth structure.

  14. Fracture Resistance of Premolars Restored by Various Types and Placement Techniques of Resin Composites

    Directory of Open Access Journals (Sweden)

    Horieh Moosavi

    2012-01-01

    Full Text Available To verify the fracture resistance of premolars with mesioocclusodistal preparations restored by different resin composites and placement techniques. Sixty premolars were randomly divided into two groups based on type of composite resin: Filtek P60 or Nulite F, and then each group was separated into three subgroups: bulk, centripetal, and fiber insert according to the type of placement method (n=10. Single-bond adhesive system was used as composite bonding according to the manufacturer's instructions. Specimens were restored in Groups 1, 2, and 3 with Filtek P60 and in Groups 4, 5, and 6 with Nulite F. After being stored 24 hours at 37∘C, a 4 mm diameter steel sphere in a universal testing machine was applied on tooth buccal and lingual cusps at a cross-head speed of 5 mm/min until fracture occurred. Groups 3 and 6 showed higher fracture resistance than Groups 1, 2, 4, and 5. Among the placement techniques, the fiber insert method had a significant effect, but the type of composite was ineffective. The insertion technique in contrast to the type of material had a significant influence on the fracture resistance of premolar teeth.

  15. Wear resistance and fracture mechanics of WC-Co composites

    International Nuclear Information System (INIS)

    Kaytbay, Saleh; El-Hadek, Medhat

    2014-01-01

    Manufacturing of WC-Co composites using the electroless precipitation method at different sintering temperatures of 1 100, 1 250, 1 350 and 1 500 C was successfully achieved. The chemical composition of the investigated materials was 90 wt.% WC with 10 wt.% Co, and 80 wt.% WC with 20 wt.% Co. The specific density, densification, and Vickers microhardness measurements were found to increase with increased sintering temperature for both the WC-Co compositions. The composites of tungsten carbide with 10 wt.% Co had a higher specific density and Vickers microhardness measurements than those for the composites of tungsten carbide with 20 wt.% Co. Composites with WC-10 wt.% Co had better wear resistance. The stress-strain and transverse rupture strength increased monotonically with the increase in sintering temperatures, agreeing with the material hardness and wear resistance behavior. Fractographical scanning electron microscopy analysis of the fracture surface demonstrated a rough characteristic conical shape failure in the direction of the maximum shear stress. A proposed mechanism for the formation of the conical fracture surface under compression testing is presented. (orig.)

  16. Effect of inadequate ferrule segment location on fracture resistance of endodontically treated teeth

    Directory of Open Access Journals (Sweden)

    Satheesh B Haralur

    2018-01-01

    Full Text Available Introduction: The circumferential 2 mm ferrule during the fabrication of the crown is strongly advocated for the long-term clinical success. During the routine clinical practice, the dentist encounters the endodontically treated tooth (ETT with inadequacy of the ferrule in some segment due to caries, abrasion, and erosions. The aim of this in vitro study was to investigate the consequence of inadequate segmental ferrule location on fracture strength of the root canal-treated anterior and posterior teeth. Materials and Methods: Fifty each maxillary canine and mandibular premolar intact human teeth were root canal treated and sectioned at 2 mm above the cementum-enamel junction. The teeth samples were divided into 5 groups of 10 each. The G-I and G-V samples had the 360° ferrule and complete absence of the ferrule, respectively. The G-II had the inadequate ferrule on the palatal surface, while G-III and G-IV had inadequate ferrule at buccal and proximal area. Teeth samples were subsequently restored with glass-reinforced fiber post, composite core, and full veneer metal crown. The samples were tested with universal testing machine under static load to record the fracture resistance. The acquired data were subjected to ANOVA and Tukey's post hoc statistical analysis. Results: The G-I with circumferential ferrule showed the higher fracture resistance. The teeth samples with lack of the ferrule had the least fracture resistance. Among the segmental absence of ferrule, teeth samples with lack of the proximal ferrule were least affected. Deficiency of a ferrule on the lingual wall significantly affected the fracture strength in both anterior and posterior ETT. Conclusions: The ETT with sectional inadequacy of the ferrule is significantly more effective in resisting the fracture in comparison to the complete absence of the ferrule.

  17. Fracture resistance of welded panel specimen with perpendicular crack in tensile

    International Nuclear Information System (INIS)

    Gochev, Todor; Adziev, Todor

    1998-01-01

    Defects caused by natural crack in welded joints of high-strength low-alloy (HSLA) steels are very often. Perpendicular crack in welded joints and its heat treatment after the welding has also an influence on the fracture resistance. The fracture resistance of welded joints by crack in tense panel specimens was investigated by crack mouse opening displesment (CMOD), the parameter of fracture mechanic. Crack propagation was analysed by using a metallographic analysis of fractured specimens after the test. (Author)

  18. Fracture resistance of teeth restored with packable and hybrid composites

    Directory of Open Access Journals (Sweden)

    Ghavam M

    2006-06-01

    Full Text Available Background and Aim: With recent introduction of packable composites, it is claimed that they apply less stress on tooth structure because of reduced polymerization shrinkage, and similarity of coefficient of thermal expansion to tooth structure. However, the high viscosity may in turn cause less adaptation, so it is not clearly known whether these materials strengthen tooth structure or not. The aim of this study was to evaluate fracture resistance of maxillary premolars, receiving hybrid or packable composite restorations with different methods of application and curing. Materials and Methods: In this experimental study, seventy five intact premolars were randomly assigned to five groups of 15 teeth each. One group was maintained intact as the control group. Similar MOD cavities were prepared in the other teeth. The teeth in group two were restored with Spectrum in incremental layers and light cured with 500 mw/cm2 intensity. The third group were filled with Surefil and cured with light intensity of 500 mw/cm2. The groups four and five were restored with Surefil in bulk technique with two different modes: 500 mw/cm2 intensity and a ramp mode (100-900 mw/cm2 respectively. After thermocycling, force to fracture was assessed and degree of conversion (DC at the bottom of cavities was evaluated for different modes and methods. The curing and placement methods in groups tested for DC (A to D were the same as fracture resistance groups (2 to 5. Data were analyzed using one way ANOVA and Tukey HSD tests with p<0.05 as the limit of significance. Results: All the restored groups showed significantly less fracture resistance than the control group, but had no significant difference among themselves. DC of Spectrum was higher than Surefil. Bulk method with 500 mw/cm2 light intensity, significantly decreased DC. DC in bulk method with high light intensity was not significantly different from incremental method with 500 mw/cm2 light intensity. Conclusion

  19. Fracture resistance of abutment screws made of titanium, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone

    Directory of Open Access Journals (Sweden)

    Eduardo Aloisio Fleck NEUMANN

    2014-08-01

    Full Text Available Fractured abutment screws may be replaced; however, sometimes, the screw cannot be removed and the entire implant must be surgically removed and replaced. The aim of this study was to compare the fracture resistance of abutment retention screws made of titanium, polyetheretherketone (PEEK and 30% carbon fiber-reinforced PEEK, using an external hexagonal implant/UCLA-type abutment interface assembly. UCLA-type abutments were fixed to implants using titanium screws (Group 1, polyetheretherketone (PEEK screws (Group 2, and 30% carbon fiber-reinforced PEEK screws (Group 3. The assemblies were placed on a stainless steel holding apparatus to allow for loading at 45o off-axis, in a universal testing machine. A 200 N load (static load was applied at the central point of the abutment extremity, at a crosshead speed of 5 mm/minute, until failure. Data was analyzed by ANOVA and Tukey’s range test. The titanium screws had higher fracture resistance, compared with PEEK and 30% carbon fiber-reinforced PEEK screws (p 0.05. Finally, visual analysis of the fractions revealed that 100% of them occurred at the neck of the abutment screw, suggesting that this is the weakest point of this unit. PEEK abutment screws have lower fracture resistance, in comparison with titanium abutment screws.

  20. Fracture resistance of abutment screws made of titanium, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone.

    Science.gov (United States)

    Neumann, Eduardo Aloisio Fleck; Villar, Cristina Cunha; França, Fabiana Mantovani Gomes

    2014-01-01

    Fractured abutment screws may be replaced; however, sometimes, the screw cannot be removed and the entire implant must be surgically removed and replaced. The aim of this study was to compare the fracture resistance of abutment retention screws made of titanium, polyetheretherketone (PEEK) and 30% carbon fiber-reinforced PEEK, using an external hexagonal implant/UCLA-type abutment interface assembly. UCLA-type abutments were fixed to implants using titanium screws (Group 1), polyetheretherketone (PEEK) screws (Group 2), and 30% carbon fiber-reinforced PEEK screws (Group 3). The assemblies were placed on a stainless steel holding apparatus to allow for loading at 45o off-axis, in a universal testing machine. A 200 N load (static load) was applied at the central point of the abutment extremity, at a crosshead speed of 5 mm/minute, until failure. Data was analyzed by ANOVA and Tukey's range test. The titanium screws had higher fracture resistance, compared with PEEK and 30% carbon fiber-reinforced PEEK screws (p 0.05). Finally, visual analysis of the fractions revealed that 100% of them occurred at the neck of the abutment screw, suggesting that this is the weakest point of this unit. PEEK abutment screws have lower fracture resistance, in comparison with titanium abutment screws.

  1. Effect of MTA and Portland Cement on Fracture Resistance of Dentin

    Directory of Open Access Journals (Sweden)

    Maryam Forghani

    2013-06-01

    Full Text Available Background and aims. It is important to evaluate the effects of endodontic materials on tooth structures to avoid endodontic treatment failure. The aim of the present study was to investigate the effect of mineral trioxide aggregates (MTA and Portland cement (PC on fracture resistance of dentin. Materials and methods. Thirty-six freshly extracted human single-rooted premolar teeth were selected. The crowns were removed and the roots were randomly divided into two experimental groups and one control group. The root samples were longitudinally divided into two halves and a dentin bar (2×2×10 mm was cut from each root section for short-term (2 weeks and long-term (12 weeks evaluations. The root sections in the experimental groups were exposed to MTA or PC, while keeping the control group specimens in physiologic saline. The fracture resistance of each specimen was measured using an Instron testing machine. The results were statistically analyzed using ANOVA, a post hoc Tukey test and paired ttest at 5% significance level. Results. The fracture resistance of MTA-treated specimens significantly increased between 2 and 12 weeks (P0.05. Conclusion. The results showed that MTA increased the fracture resistance of root dentin, while PC had no significant effect on dentin fracture resistance.

  2. Effect of different composite core materials on fracture resistance of endodontically treated teeth restored with FRC posts.

    Science.gov (United States)

    Panitiwat, Prapaporn; Salimee, Prarom

    2017-01-01

    This study evaluated the fracture resistance of endodontically treated teeth restored with fiber reinforced composite posts, using three resin composite core build-up materials, (Clearfil Photo Core (CPC), MultiCore Flow (MCF), and LuxaCore Z-Dual (LCZ)), and a nanohybrid composite, (Tetric N-Ceram (TNC)). Forty endodontically treated lower first premolars were restored with quartz fiber posts (D.T. Light-Post) cemented with resin cement (Panavia F2.0). Samples were randomly divided into four groups (n=10). Each group was built-up with one of the four core materials following its manufacturers' instructions. The teeth were embedded in acrylic resin blocks. Nickel-Chromium crowns were fixed on the specimens with resin cement. The fracture resistance was determined using a universal testing machine with a crosshead speed of 1 mm/min at 1350 to the tooth axis until failure occurred. All core materials used in the study were subjected to test for the flexural modulus according to ISO 4049:2009. One-way ANOVA and Bonferroni multiple comparisons test indicated that the fracture resistance was higher in the groups with CPC and MCF, which presented no statistically significant difference (p>0.05), but was significantly higher than in those with LCZ and TNC (paligned with the same tendency of fracture loads. Among the cores used in this study, the composite core with high filler content tended to enhance fracture thresholds of teeth restored with fiber posts more than others.

  3. Influence of intracanal irrigants on coronal fracture resistance of endodontically treated and bleached teeth: An In vitro Study

    Directory of Open Access Journals (Sweden)

    Maryam Khoroushi

    2017-01-01

    Full Text Available Background: Irrigation has a key role in the success of endodontic treatment. Intracanal irrigant solutions have adverse effects on the physical properties of dentin. Aim: The present study aimed to evaluate the effect of different irrigation protocols on coronal fracture resistance of endodontically treated teeth undergoing bleaching treatment. Design and Materials and Methods: Access cavities were prepared in 120 maxillary premolars which were divided into two groups (n = 60 – Group A: nonbleached, Group B: bleached (B. Each group was subdivided into five subgroups based on irrigation protocol (n = 12; G1: normal saline (NS, G2: 2.5% sodium hypochlorite (NaOCl, G3: 10% citric acid (CA, G4: 17% ethylene diamine tetra acetic acid, and G5: NaOCl plus CA. In Group B, the teeth were bleached using 38% hydrogen peroxide and 20% carbamide peroxide gels as in-office and at-home bleaching techniques for 3 weeks. All the teeth were restored with composite resin, thermocycled, and incubated for 24 h. The specimens underwent fracture resistance tests. Data were analyzed with ANOVA, Tukey honestly significant difference test, t-test, and Chi-squared test (α =0.05. Results: T-test showed significant differences between each two corresponding subgroups (P < 0.0001. In Group A, NS demonstrated significantly higher fracture resistance compared to others; however, minimum fracture resistance recorded in G2. In Group B, the maximum fracture resistance was recorded in G1, with the minimum being recorded in G5. Samples irrigated with NaOCl and NaOCl plus CA exhibited significantly lower fracture resistance compared to NS subgroup (P < 0.05. Conclusions: Within the limitations of this study, it can be concluded that the irrigation protocol used during endodontic treatment with/without bleaching can affect the coronal fracture resistance.

  4. Derivation of Path Independent Coupled Mix Mode Cohesive Laws from Fracture Resistance Curves

    DEFF Research Database (Denmark)

    Goutianos, Stergios

    2016-01-01

    A generalised approach is presented to derive coupled mixed mode cohesive laws described with physical parameters such as peak traction, critical opening, fracture energy and cohesive shape. The approach is based on deriving mix mode fracture resistance curves from an effective mix mode cohesive...... law at different mode mixities. From the fracture resistance curves, the normal and shear stresses of the cohesive laws can be obtained by differentiation. Since, the mixed mode cohesive laws are obtained from a fracture resistance curve (potential function), path independence is automatically...

  5. Correlation of physical properties of ceramic materials with resistance to fracture by thermal shock

    Science.gov (United States)

    Lidman, W G; Bobrowsky, A R

    1949-01-01

    An analysis is made to determine which properties of materials affect their resistance to fracture by thermal stresses.From this analysis, a parameter is evaluated that is correlated with the resistance of ceramic materials to fracture by thermal shock as experimentally determined. This parameter may be used to predict qualitatively the resistance of a material to fracture by thermal shock. Resistance to fracture by thermal shock is shown to be dependent upon the following material properties: thermal conductivity, tensile strength, thermal expansion, and ductility modulus. For qualitative prediction of resistance of materials to fracture by thermal shock, the parameter may be expressed as the product of thermal conductivity and tensile strength divided by the product of linear coefficient of thermal expansion and ductility modulus of the specimen.

  6. The Effect of Diode Laser Treatment for Root Canal Disinfection on Fracture Resistance and Micro-hardness of the Tooth

    International Nuclear Information System (INIS)

    Elmiligy, H.H; Diab, A.H.; Sabet, N.E.; Saafan, A.M.

    2014-01-01

    This study evaluated the effect of diode laser treatment for root canal disinfection on fracture resistance and micro-hardness of the tooth. Sixty freshly extracted mandibular and maxillary premolars were accessed under coolant then root canals were flared up to apical preparation size 40 MFA coupled with 5.25% NaOCl as an irrigant. Teeth were divided into two groups, control group (group I) and lased group (group II) that was lased by diode laser with average power 2 w through fibrooptic into the canal 2 mm shorter than the apex. Each tooth was embedded in acrylic block, and then subjected to the fracture resistance test. Each root was then sectioned transversely and polished to record dentin Vickers hardness. Data was analysed with student t-test then with linear regression test. The Lased samples presented a significantly higher resistance to fracture than unlased samples. There was no statistically significant differences found between Vickers hardness (HV) of lased and unlased samples and there was no relation between fracture resistance and microhardness. Diode laser (980 nm) treatment had no adverse effect on dentin microhardness, also it increased the fracture resistance of dentin. Diode laser (980 nm) treatment could attain better function ability and maintenance of tooth after endodontic treatment.

  7. Fracture resistance of structurally compromised and normal endodontically treated teeth restored with different post systems: An in vitro study

    Directory of Open Access Journals (Sweden)

    Vajihesadat Mortazavi

    2012-01-01

    Full Text Available Background: With the aim of developing methods that could increase the fracture resistance of structurally compromised endodontically treated teeth, this study was conducted to compare the effect of three esthetic post systems on the fracture resistance and failure modes of structurally compromised and normal roots. Materials and Methods: Forty five extracted and endodontically treated maxillary central teeth were assigned to 5 experimental groups (n=9. In two groups, the post spaces were prepared with the corresponding drills of the post systems to be restored with double taper light posts (DT.Light-Post (group DT.N and zirconia posts (Cosmopost (group Zr.N. In other 3 groups thin wall canals were simulated to be restored with Double taper Light posts (DT.W, double taper Light posts and Ribbond fibers (DT+R.W and Zirconia posts (Zr.W. After access cavity restoration and thermocycling, compressive load was applied and the fracture strength values and failure modes were evaluated. Data were analyzed using two-way ANOVA, Tukey and Fisher exact tests (P<0.05. Results: The mean failure loads (N were 678.56, 638.22, 732.44, 603.44 and 573.67 for groups DT.N, Zr.N, DT.W, DT+R.W and Zr.w respectively. Group DT+R.W exhibited significantly higher resistance to fracture compared to groups Zr.N, DT.W and Zr.w (P<0.05. A significant difference was detected between groups DT.N and Zr.W (P=0.027. Zirconia posts showed significantly higher root fracture compared to fiber posts (P=0.004. Conclusion: The structurally compromised teeth restored with double taper light posts and Ribbond fibers showed the most fracture resistance and their strengths were comparable to those of normal roots restored with double taper light posts. More desirable fracture patterns were observed in teeth restored with fiber posts.

  8. Fracture resistance of Kevlar-reinforced poly(methyl methacrylate) resin: a preliminary study.

    Science.gov (United States)

    Berrong, J M; Weed, R M; Young, J M

    1990-01-01

    The reinforcing effect of Kevlar fibers incorporated in processed poly(methyl methacrylate) resin samples was studied using 0% (controls), 0.5%, 1%, and 2% by weight of the added fibers. The samples were subjected to impact testing to determine fracture resistance, and sample groups were statistically compared using an ANOVA. Each reinforced sample had significantly greater fracture resistance (P less than 0.05) than the control, and no difference was found either within or between control groups. The use of reinforcing Kevlar fibers appears to enhance the fracture resistance of acrylic resin denture base materials.

  9. Effect of Different Liners on Fracture Resistance of Premolars Restored with Conventional and Short Fiber-Reinforced Composite Resins.

    Science.gov (United States)

    Shafiei, Fereshteh; Doozandeh, Maryam; Ghaffaripour, Dordaneh

    2018-01-11

    To see whether applying four different liners under short fiber-reinforced composite (SFRC), everX Posterior, compared to conventional composite resin, Z250, affected their strengthening property in premolar MOD cavities. Mesio-occluso-distal (MOD) cavities were prepared in 120 sound maxillary premolars divided into 10 groups (n = 12) in terms of two composite resin types and 4 liners or no liner. For each composite resin, in 5 groups no liner, resin-modified glass ionomer (RMGI), conventional flowable composite (COFL), self-adhesive flowable composite resin (SAFL), and self-adhesive resin cement (SARC) were applied prior to restoring incrementally. After water storage and thermocycling, static fracture resistance was tested. Data (in Newtons) were analyzed using two-way ANOVA (α = 0.05). Fracture resistance was significantly affected by composite resin type (p = 0.02), but not by the liner (p > 0.05). The interaction of the two factors was not statistically significant (p > 0.05). SFRC exhibited higher fracture strength (1470 ± 200 N) compared to conventional composite resin (1350 ± 290), irrespective of the application of liners. Application of SARC and SAFL liners led to a higher number of restorable fractures for both composite resins. The four liners can be used without interfering with the higher efficacy of SFRC, compared to conventional composite resins, to improve the fracture strength of premolar MOD cavities. © 2018 by the American College of Prosthodontists.

  10. Influence of the preparation design and artificial aging on the fracture resistance of monolithic zirconia crowns.

    Science.gov (United States)

    Mitov, Gergo; Anastassova-Yoshida, Yana; Nothdurft, Frank Phillip; von See, Constantin; Pospiech, Peter

    2016-02-01

    The aim of this study was to evaluate the fracture resistance and fracture behavior of monolithic zirconia crowns in accordance with the preparation design and aging simulation method. An upper first molar was prepared sequentially with three different preparation designs: shoulderless preparation, 0.4 mm chamfer and 0.8 mm chamfer preparation. For each preparation design, 30 monolithic zirconia crowns were fabricated. After cementation on Cr-Co alloy dies, the following artificial aging procedures were performed: (1) thermal cycling and mechanical loading (TCML): 5000 cycles of thermal cycling 5℃-55℃ and chewing simulation (1,200,000 cycles, 50 N); (2) Low Temperature Degradation simulation (LTD): autoclave treatment at 137℃, 2 bar for 3 hours and chewing simulation; and (3) no pre-treatment (control group). After artificial aging, the crowns were loaded until fracture. The mean values of fracture resistance varied between 3414 N (LTD; 0.8 mm chamfer preparation) and 5712 N (control group; shoulderless preparation). Two-way ANOVA analysis showed a significantly higher fracture loads for the shoulderless preparation, whereas no difference was found between the chamfer preparations. In contrast to TCML, after LTD simulation the fracture strength of monolithic zirconia crowns decreased significantly. The monolithic crowns tested in this study showed generally high fracture load values. Preparation design and LTD simulation had a significant influence on the fracture strength of monolithic zirconia crowns.

  11. Higher incidence of hip fracture in newly diagnosed schizophrenic ...

    African Journals Online (AJOL)

    Higher incidence of hip fracture in newly diagnosed schizophrenic patients in Taiwan. Hip fracture is a major public health concern due to its poor outcome and serious socioeconomic burden in older people (1). Evidence has shown that many factors are related to increased risk of hip fracture, but psychiatric diseases are ...

  12. Fracture resistance of computer-aided design and computer-aided manufacturing ceramic crowns cemented on solid abutments.

    Science.gov (United States)

    Stona, Deborah; Burnett, Luiz Henrique; Mota, Eduardo Gonçalves; Spohr, Ana Maria

    2015-07-01

    Because no information was found in the dental literature regarding the fracture resistance of all-ceramic crowns using CEREC (Sirona) computer-aided design and computer-aided manufacturing (CAD-CAM) system on solid abutments, the authors conducted a study. Sixty synOcta (Straumann) implant replicas and regular neck solid abutments were embedded in acrylic resin and randomly assigned (n = 20 per group). Three types of ceramics were used: feldspathic, CEREC VITABLOCS Mark II (VITA); leucite, IPS Empress CAD (Ivoclar Vivadent); and lithium disilicate, IPS e.max CAD (Ivoclar Vivadent). The crowns were fabricated by the CEREC CAD-CAM system. After receiving glaze, the crowns were cemented with RelyX U200 (3M ESPE) resin cement under load of 1 kilogram. For each ceramic, one-half of the specimens were subjected to the fracture resistance testing in a universal testing machine with a crosshead speed of 1 millimeter per minute, and the other half were subjected to the fractured resistance testing after 1,000,000 cyclic fatigue loading at 100 newtons. According to a 2-way analysis of variance, the interaction between the material and mechanical cycling was significant (P = .0001). According to a Tukey test (α = .05), the fracture resistance findings with or without cyclic fatigue loading were as follows, respectively: CEREC VITABLOCKS Mark II (405 N/454 N) was statistically lower than IPS Empress CAD (1169 N/1240 N) and IPS e.max CAD (1378 N/1025 N) (P Empress CAD and IPS e.max CAD did not differ statistically (P > .05). According to a t test, there was no statistical difference in the fracture resistance with and without cyclic fatigue loading for CEREC VITABLOCS Mark II and IPS Empress CAD (P > .05). For IPS e.max CAD, the fracture resistance without cyclic fatigue loading was statistically superior to that obtained with cyclic fatigue loading (P Empress CAD and IPS e.max CAD showed higher fracture resistance compared with CEREC VITABLOCS Mark II. The cyclic

  13. Evaluation of Fracture Resistance in Root Canal-Treated Teeth ...

    African Journals Online (AJOL)

    2018-06-11

    Jun 11, 2018 ... Objective: This study aimed to evaluate the effects of different coronal restoration techniques on fracture ... Therefore, the application of horizontal fiber posts in. MOD cavities has .... Table 1: Median and 25% and 75% quartile values of the groups n ..... restorations on fracture resistance and failure mode of.

  14. Fracture resistance of teeth submitted to several internal bleaching protocols.

    Science.gov (United States)

    Leonardo, Renato de Toledo; Kuga, Milton Carlos; Guiotti, Flávia Angélica; Andolfatto, Carolina; Faria-Júnior, Norberto Batista de; Campos, Edson Alves de; Keine, Kátia Cristina; Dantas, Andrea Abi Rached

    2014-03-01

    The aim of this study was to evaluate the fracture resistance of teeth submitted to several internal bleaching protocols using 35% hydrogen peroxide (35HP), 37% carbamide peroxide (37CP), 15% hydrogen peroxide with titanium dioxide nanoparticles (15HPTiO2) photoactivated by LED-laser or sodium perborate (SP). After endodontic treatment, fifty bovine extracted teeth were divided into five groups (n = 10): G1-unbleached; G2-35HP; G3-37CP; G4-15HPTiO2 photoactivated by LED-laser and G5-SP. In the G2 and G4, the bleaching protocol was applied in 4 sessions, with 7 days intervals between each session. In the G3 and G5, the materials were kept in the pulp teeth for 21 days, but replaced every 7 days. After 21 days, the teeth were subjected to compressive load at a cross head speed of 0.5 mm/min, applied at 135° to the long axis of the root using an eletromechanical testing machine, until teeth fracture. The data were submitted to ANOVA and Tukey tests (α = 5%). The 35HP, 37CP, 15HPTiO2 and SP showed similar fracture resistance teeth reduction (p > 0.05). All bleaching treatments reduced the fracture resistance compared to unbleached teeth (p endodontically-treated teeth, but there were no differences between each other. There are several internal bleaching protocols using hydrogen peroxide in different concentrations and activation methods. This study evaluated its effects on fracture resistance in endodontically-treated teeth.

  15. An approach to ductile fracture resistance modelling in pipeline steels

    Energy Technology Data Exchange (ETDEWEB)

    Pussegoda, L.N.; Fredj, A. [BMT Fleet Technology Ltd., Kanata (Canada)

    2009-07-01

    Ductile fracture resistance studies of high grade steels in the pipeline industry often included analyses of the crack tip opening angle (CTOA) parameter using 3-point bend steel specimens. The CTOA is a function of specimen ligament size in high grade materials. Other resistance measurements may include steady state fracture propagation energy, critical fracture strain, and the adoption of damage mechanisms. Modelling approaches for crack propagation were discussed in this abstract. Tension tests were used to calibrate damage model parameters. Results from the tests were then applied to the crack propagation in a 3-point bend specimen using modern 1980 vintage steels. Limitations and approaches to overcome the difficulties associated with crack propagation modelling were discussed.

  16. Fracture resistance of dental nickel-titanium rotary instruments with novel surface treatment: Thin film metallic glass coating.

    Science.gov (United States)

    Chi, Chih-Wen; Deng, Yu-Lun; Lee, Jyh-Wei; Lin, Chun-Pin

    2017-05-01

    Dental nickel-titanium (NiTi) rotary instruments are widely used in endodontic therapy because they are efficient with a higher success rate. However, an unpredictable fracture of instruments may happen due to the surface characteristics of imperfection (or irregularity). This study assessed whether a novel surface treatment could increase fatigue fracture resistance of dental NiTi rotary instruments. A 200- or 500-nm thick Ti-zirconium-boron (Ti-Zr-B) thin film metallic glass was deposited on ProTaper Universal F2 files using a physical vapor deposition process. The characteristics of coating were analyzed by scanning electron microscopy, transmission electron microscopy, and X-ray diffractometry. In cyclic fatigue tests, the files were performed in a simulated root canal (radius=5 mm, angulation=60°) under a rotating speed of 300rpm. The fatigue fractured cross sections of the files were analyzed with their fractographic performances through scanning electron microscopy images. The amorphous structure of the Ti-Zr-B coating was confirmed by transmission electron microscopy and X-ray diffractometry. The surface of treated files presented smooth morphologies without grinding irregularity. For the 200- and 500-nm surface treatment groups, the coated files exhibited higher resistance of cyclic fatigue than untreated files. In fractographic analysis, treated files showed significantly larger crack-initiation zone; however, no significant differences in the areas of fatigue propagation and catastrophic fracture were found compared to untreated files. The novel surface treatment of Ti-Zr-B thin film metallic glass on dental NiTi rotary files can effectively improve the fatigue fracture resistance by offering a smooth coated surface with amorphous microstructure. Copyright © 2016. Published by Elsevier B.V.

  17. Effect of different composite core materials on fracture resistance of endodontically treated teeth restored with FRC posts

    Directory of Open Access Journals (Sweden)

    Prapaporn PANITIWAT

    Full Text Available Abstract Objective This study evaluated the fracture resistance of endodontically treated teeth restored with fiber reinforced composite posts, using three resin composite core build-up materials, (Clearfil Photo Core (CPC, MultiCore Flow (MCF, and LuxaCore Z-Dual (LCZ, and a nanohybrid composite, (Tetric N-Ceram (TNC. Material and Methods Forty endodontically treated lower first premolars were restored with quartz fiber posts (D.T. Light-Post cemented with resin cement (Panavia F2.0. Samples were randomly divided into four groups (n=10. Each group was built-up with one of the four core materials following its manufacturers’ instructions. The teeth were embedded in acrylic resin blocks. Nickel-Chromium crowns were fixed on the specimens with resin cement. The fracture resistance was determined using a universal testing machine with a crosshead speed of 1 mm/min at 1350 to the tooth axis until failure occurred. All core materials used in the study were subjected to test for the flexural modulus according to ISO 4049:2009. Results One-way ANOVA and Bonferroni multiple comparisons test indicated that the fracture resistance was higher in the groups with CPC and MCF, which presented no statistically significant difference (p>0.05, but was significantly higher than in those with LCZ and TNC (p<0.05. In terms of the flexural modulus, the ranking from the highest values of the materials was aligned with the same tendency of fracture loads. Conclusion Among the cores used in this study, the composite core with high filler content tended to enhance fracture thresholds of teeth restored with fiber posts more than others.

  18. Effects of solidified microstructures on J-R fracture resistances of the surge line pipe welds

    International Nuclear Information System (INIS)

    Youn, J. H.; Lee, B. S.; Yoo, W.

    2003-01-01

    The cause of the difference in J-R fracture resistances of AISI Type 347 GTAW welds which had almost same amounts of chromium carbides were investigated by the microstructural observations. As a result, the difference in the fracture resistances with the morphologies of the retained δ-ferrites in Type 347 welds were observed. The fracture resistance of the weld which had mostly vermicular type δ-ferrites was inferior to the weld which has lacy and acicular mixed type δ-ferrites. Therefore, it was deduced that the morphology of δ-ferrites affected the J-R fracture resistances of Type 347 welds

  19. Fracture Resistances of Y_2O_3 Particle Dispersion Strengthened 9Cr Steel at Room Temperature and High Temperatures

    International Nuclear Information System (INIS)

    Yoon, Ji Hyun; Kang, Suk Hoon; Lee, Yongbok; Kim, Sung Soo

    2012-01-01

    The fracture resistance and tensile properties of Y_2O_3 oxide dispersion strengthened steel containing 9 wt% Cr (9Cr-ODS) were measured at various temperatures up to 700°C. The fracture characteristics were compared with those of commercial E911 ferritic/martensitic steel. The strength of 9Cr-ODS was at least 30% higher than that of E911 steel at the test temperatures below 500°C. The strength difference between the two materials was almost diminished at 700°C. 9Cr-ODS showed cleavage fracture behavior at room temperature and unstable crack growth behaviors at 300°C and 500°C. The J-R fracture resistance of 9Cr-ODS was much lower than that of E911 steel at all temperatures. It was deduced that the coarse Cr_2O_3 particles that were formed during the alloying process provided the crack initiation sites of cleavage fracture in 9Cr-ODS.

  20. Hidden contributions of the enamel rods on the fracture resistance of human teeth.

    Science.gov (United States)

    Yahyazadehfar, M; Bajaj, Devendra; Arola, Dwayne D

    2013-01-01

    The enamel of human teeth is generally regarded as a brittle material with low fracture toughness. Consequently, the contributions of this tissue in resisting tooth fracture and the importance of its complex microstructure have been largely overlooked. In this study an experimental evaluation of the crack growth resistance of human enamel was conducted to characterize the role of rod (i.e. prism) orientation and degree of decussation on the fracture behavior of this tissue. Incremental crack growth was achieved in-plane, with the rods in directions longitudinal or transverse to their axes. Results showed that the fracture resistance of enamel is both inhomogeneous and spatially anisotropic. Cracks extending transverse to the rods in the outer enamel undergo a lower rise in toughness with extension, and achieve significantly lower fracture resistance than in the longitudinal direction. Though cracks initiating at the surface of teeth may begin extension towards the dentin-enamel junction, they are deflected by the decussated rods and continue growth about the tooth's periphery, transverse to the rods in the outer enamel. This process facilitates dissipation of fracture energy and averts cracks from extending towards the dentin and vital pulp. Copyright © 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  1. Fracture resistance and fatigue crack growth characteristics of two Al-Cu-Mg-Zr alloys

    Science.gov (United States)

    Sarkar, Bhaskar; Lisagor, W. B.

    1992-01-01

    The dependence of strength, fracture resistance, and fatigue crack growth rate on the aging conditions of two alloy compositions based on Al-3.7Cu-1.85Mg-0.2Mn is investigated. Mechanical properties were evaluated in two heat treatment conditions and in two orientations (longitudinal and transverse). Compact tension specimens were used to determine fatigue crack growth characteristics and fracture resistance. The aging response was monitored on coupons using hardness measurements determined with a standard Rockwell hardness tester. Fracture resistance is found to increase with increasing yield strength during artificial aging of age-hardenable 2124-Zr alloys processed by powder metallurgy techniques. Fatigue crack growth rate increases with increasing strength. It is argued that these changes are related to deformation modes of the alloys; a homogeneous deformation mode tends to increase fracture resistance and to decrease the resistance to the fatigue crack propagation rate.

  2. Fracture processes and mechanisms of crack growth resistance in human enamel

    Science.gov (United States)

    Bajaj, Devendra; Park, Saejin; Quinn, George D.; Arola, Dwayne

    2010-07-01

    Human enamel has a complex micro-structure that varies with distance from the tooth’s outer surface. But contributions from the microstructure to the fracture toughness and the mechanisms of crack growth resistance have not been explored in detail. In this investigation the apparent fracture toughness of human enamel and the mechanisms of crack growth resistance were evaluated using the indentation fracture approach and an incremental crack growth technique. Indentation cracks were introduced on polished surfaces of enamel at selected distances from the occlusal surface. In addition, an incremental crack growth approach using compact tension specimens was used to quantify the crack growth resistance as a Junction of distance from the occlusal surface. There were significant differences in the apparent toughness estimated using the two approaches, which was attributed to the active crack length and corresponding scale of the toughening mechanisms.

  3. [Fracture resistance of Procera Allceram depending on the framework design--an in vitro study].

    Science.gov (United States)

    Hagmann, Edgar; Marinello, Carlo P; Zitzmann, Nicola U

    2006-01-01

    Procera AllCeram is one of the all-ceramic systems with an aluminium-oxide core employing CAD/CAM technology. The aim of the current study was to investigate the fracture resistance of Procera AllCeram full-ceramic crowns with a reduced core design compared to the conventional method. In addition, a possible influence of the preparation form (molars or premolars) and the cementation material (glas-ionomer or composite) was analyzed. For both preparation forms, 30 ceramic cores with reduced margins (collarless cores, test) and 30 cores with extended cores (control) were veneered with porcelain in a standardized procedure (total 120 crowns). For the test group, Procera-AllCeram-margin ceramic material was used for the porcelain collar. 40 crowns each were cemented on stainless steel dies with either Ketac-Cem Aplicap or Panavia F. The additional 40 crowns were set on polyurethane dies without cementation and occlusally loaded until fracture occurred. Among the molar crowns, no differences were observed in fracture resistance neither for the different core designs (test or control) nor for the cementation materials. For the premolar form, fusing of a porcelain margin was associated with a reduction in fracture resistance, while the use of composite cement was accompanied with an increase. The present in vitro results indicate that for Procera AllCeram crowns with a highly undulating preparation margin, a conventional core design combined with adhesive cementation is preferable, especially in the posterior region due to higher chewing forces; this assumption needs to be proven in clinical studies.

  4. Hidden contributions of the enamel rods on the fracture resistance of human teeth

    OpenAIRE

    Yahyazadehfar, M.; Bajaj, Devendra; Arola, Dwayne D.

    2012-01-01

    The enamel of human teeth is generally regarded as a brittle material with low fracture toughness. Consequently, the contributions of this tissue in resisting tooth fracture and the importance of its complex microstructure have been largely overlooked. In this study an experimental evaluation of the crack growth resistance of human enamel was conducted to characterize the role of rod (i.e. prism) orientation and degree of decussation on the fracture behavior of this tissue. Incremental crack ...

  5. Relative permeability of fractured wellbore cement: an experimental investigation using electrical resistivity monitoring for moisture content

    Science.gov (United States)

    Um, W.; Rod, K. A.; Strickland, C. E.

    2016-12-01

    Permeability is a critical parameter needed to understand flow in subsurface environments; it is particularly important in deep subsurface reservoirs where multiphase fluid flow is common, such as carbon sequestration and geothermal reservoirs. Cement is used in the annulus of wellbores due to its low permeable properties to seal aquifers, reducing leaks to adjacent strata. Extreme subsurface environments of CO2 storage and geothermal production conditions will eventually reduce the cement integrity, propagating fracture networks and increasing the permeability for air and/or water. To date, there have been no reproducible experimental investigations of relative permeability in fractured wellbore cement published. To address this gap, we conducted a series of experiments using fractured Portland cement monoliths with increasing fracture networks. The monolith cylinder sides were jacketed with heavy-duty moisture-seal heat-shrink tubing, then fractured using shear force applied via a hydraulic press. Fractures were generated with different severity for each of three monoliths. Stainless steel endcaps were fixed to the monoliths using the same shrink-wrapped jacket. Fracture characteristics were determined using X-ray microtomography and image analysis. Flow controllers were used to control flow of water and air to supply continuous water or water plus air, both of which were delivered through the influent end cap. Effluent air flow was monitored using a flow meter, and water flow was measured gravimetrically. To monitor the effective saturation of the fractures, a RCON2 concrete bulk electrical resistivity test device was attached across both endcaps and a 0.1M NaNO3 brine was used as the transport fluid to improve resistivity measurements. Water content correlated to resistivity measurements with a r2 > 0.96. Data from the experiments was evaluated using two relative permeability models, the Corey-curve, often used for modeling relative permeability in porous media

  6. Temperature effect on crack resistance and fracture micromechanisms in tungsten-copper pseudoalloy

    International Nuclear Information System (INIS)

    Babak, A.V.; Gopkalo, E.E.; Krasovskij, A.Ya.; Nadezhdin, G.N.; Uskov, E.I.

    1988-01-01

    Results of the mechanical- and-physical study of peculiarities of the tungsten-copper pseudoalloy fracture in the temperature range of 293-2273 K are presented. It is shown that the studied material possesses maximum crack resistance in the vicinity of the upper temperature range boundary of the ductile-brittle transition and minimum resistance to cracks propagation when it contains melted copper. It is established that the peculiarities of changes in crack-resistance correspond to peculiarities of fracture micromechanisms for tungsten-copper pseudoalloy in the studied tempearture range

  7. In vitro fracture resistance of fiber reinforced cusp-replacing composite restorations.

    NARCIS (Netherlands)

    Fennis, W.M.M.; Tezvergil, A.; Kuijs, R.H.; Lassila, L.V.; Kreulen, C.M.; Creugers, N.H.J.; Vallittu, P.K.

    2005-01-01

    OBJECTIVES: To assess the fracture resistance and failure mode of fiber reinforced composite (FRC) cusp-replacing restorations in premolars. METHODS: Forty-five extracted sound upper premolars were randomly divided into three groups. Identical MOD cavities with simulated buccal cusp fracture and

  8. Fracture Resistance of Zirconia Restorations with a Modified Framework Design

    Directory of Open Access Journals (Sweden)

    sakineh Nikzadjamnani

    2017-12-01

    Full Text Available Objectives: Chipping is one of the concerns related to zirconia crowns. The reasons of chipping have not been completely understood. This in-vitro study aimed to assess the effect of coping design on the fracture resistance of all-ceramic single crowns with zirconia frameworks. Materials and Methods: Two types of zirconia copings were designed (n=12: (1 a standard coping (SC with a 0.5mm uniform thickness and (2 a modified coping (MC consisted of a lingual margin of 1mm thickness and 2mm height connected to a proximal strut of 4mm height and a 0.3mm-wide facial collar. After veneer porcelain firing, the crowns were cemented to metal dies. Afterwards, a static vertical load was applied until failure. The modes of failure were determined. Data were calculated and statistically analyzed by independent samples T-test. P<0.05 was considered statistically significant.Results: The mean and standard deviation (SD of the final fracture resistance equaled to 3519.42±1154.96 N and 3570.01±1224.33 N in SC and MC groups, respectively; the difference was not statistically significant (P=0.9. Also, the mean and SD of the initial fracture resistance equaled to 3345.34±1190.93 N and 3471.52±1228.93 N in SC and MC groups, respectively (P=0.8. Most of the specimens in both groups showed the mixed failure mode. Conclusions: Based on the results, the modified core design may not significantly improve the fracture resistance.

  9. Fracture resistance of endodontically treated roots filled with resilon and guttapercha - A comparative in-vitro study

    Directory of Open Access Journals (Sweden)

    Rajesh R Shetty

    2009-01-01

    Full Text Available Aims and objectives: The purpose of this study was to evaluate and compare in vitro the fracture resistance of endodontically treated roots filled with Resilon and Gutta-percha. Methodology: Eighty extracted single canal teeth were selected and randomly assigned to five groups of sixteen teeth each. Teeth were sectioned using a diamond disc so as to obtain a root length of 14±1 mm. Roots were instrumented using .04 taper Profile rotary system to an apical size of 40 and obturated using .04 taper single cone (size 40 as follows: Group 1: Resilon .04 taper cone and Epiphany Self etching sealer, Group 2: .04 taper gutta-percha cone and AH Plus sealer ,Group 3: .04 taper gutta-percha cone and Roeko Seal Automix sealer, Group 4: .04 taper gutta-percha cone and Zinc oxide Eugenol sealer , Group 5: .04 taper gutta-percha cone without the use of a sealer. Following obturation, teeth were mounted in Poly Vinyl Chloride jigs using self cure acrylic resin such that 9mm of the root remained exposed. Fracture resistance testing was done using Instron testing machine using a vertical load applied perpendicular to the root surface. Statistical analysis was done using ANOVA, Tukey HSD and Student′s ′t′ test. Results: Very highly significant difference was observed between the groups (P=.001. Resilon with Epiphany group demonstrated highest mean fracture resistance value and gutta-percha without sealer displayed the least, comparative results were highly significant. Resilon compared to gutta-percha with Roeko Seal Automix (P=.037 and Zinc Oxide Eugenolsealers (P=.029 showed statistically significant difference. AH plus group showed significantly higher value compared to gutta-percha without sealer. Conclusions: Filling the root canals with Resilon increased the in vitro fracture resistance of endodontically treated roots compared to standard gutta-percha techniques. Adhesive sealers are more beneficial in increasing the fracture resistance of

  10. Finite element analysis and fracture resistance testing of a new intraradicular post

    Directory of Open Access Journals (Sweden)

    Eron Toshio Colauto Yamamoto

    2012-08-01

    Full Text Available OBJECTIVES: The objective of the present study was to evaluate a prefabricated intraradicular threaded pure titanium post, designed and developed at the São José dos Campos School of Dentistry - UNESP, Brazil. This new post was designed to minimize stresses observed with prefabricated post systems and to improve cost-benefits. MATERIAL AND METHODS: Fracture resistance testing of the post/core/root complex, fracture analysis by microscopy and stress analysis by the finite element method were used for post evaluation. The following four prefabricated metal post systems were analyzed: group 1, experimental post; group 2, modification of the experimental post; group 3, Flexi Post, and group 4, Para Post. For the analysis of fracture resistance, 40 bovine teeth were randomly assigned to the four groups (n=10 and used for the fabrication of test specimens simulating the situation in the mouth. The test specimens were subjected to compressive strength testing until fracture in an EMIC universal testing machine. After fracture of the test specimens, their roots were sectioned and analyzed by microscopy. For the finite element method, specimens of the fracture resistance test were simulated by computer modeling to determine the stress distribution pattern in the post systems studied. RESULTS: The fracture test presented the following averages and standard deviation: G1 (45.63±8.77, G2 (49.98±7.08, G3 (43.84±5.52, G4 (47.61±7.23. Stress was homogenously distributed along the body of the intraradicular post in group 1, whereas high stress concentrations in certain regions were observed in the other groups. These stress concentrations in the body of the post induced the same stress concentration in root dentin. CONCLUSIONS: The experimental post (original and modified versions presented similar fracture resistance and better results in the stress analysis when compared with the commercial post systems tested (08/2008-PA/CEP.

  11. Determining the fracture resistance of advanced SiC fiber reinforced SiC matrix composites

    International Nuclear Information System (INIS)

    Nozawa, T.; Katoh, Y.; Kishimoto, H.

    2007-01-01

    Full text of publication follows: One of the perceived advantages for highly-crystalline and stoichiometric silicon carbide (SiC) and SiC composites, e.g., advanced SiC fiber reinforced chemically-vapor-infiltrated (CVI) SiC matrix composites, is the retention of fast fracture properties after neutron irradiation at high-temperatures (∼1000 deg. C) to intermediate-doses (∼15 dpa). Accordingly, it has been clarified that the maximum allowable stress (or strain) limit seems unaffected in certain irradiation conditions. Meanwhile, understanding the mechanism of crack propagation from flaws, as potential weakest link to cause composite failure, is somehow lacking, despite that determining the strength criterion based on the fracture mechanics will eventually become important considering the nature of composites' fracture. This study aims to evaluate crack propagation behaviors of advanced SiC/SiC and to provide fundamentals on fracture resistance of the composites to define the strength limit for the practical component design. For those purposes, the effects of irreversible energies related to interfacial de-bonding, fiber bridging, and microcrack forming on the fracture resistance were evaluated. Two-dimensional SiC/SiC composites were fabricated by CVI or nano-infiltration and transient-eutectic-phase (NITE ) methods. Hi-Nicalon TM Type-S or Tyranno TM -SA fibers were used as reinforcements. In-plane mode-I fracture resistance was evaluated by the single edge notched bend technique. The key finding is the continuous Load increase with the crack growth for any types of advanced composites, while many studies specified the gradual load decrease for the conventional composites once the crack initiates. This high quasi-ductility appeared due primarily to high friction (>100 MPa) at the fiber/matrix interface using rough SiC fibers. The preliminary analysis based on the linear elastic fracture mechanics, which does not consider the effects of irreversible energy

  12. Fracture Resistance, Surface Defects and Structural Strength of Glass

    OpenAIRE

    Rodichev, Y.M.; Veer, F.A.

    2010-01-01

    This paper poses the theory that the fracture resistance of basic float glass is dependent on it physicochemical properties and the surface defects fonned under the float glass production, glass processing and handling at the service conditions compose the aggregate basis for structural glass strength assessment. The effect of loading conditions, constructional and technological factors on the engineering strength of glass can be evaluated in certain cases using fracture mechanics with inform...

  13. Fracture resistance and failure modes of polymer infiltrated ceramic endocrown restorations with variations in margin design and occlusal thickness.

    Science.gov (United States)

    Taha, Doaa; Spintzyk, Sebastian; Schille, Christine; Sabet, Ahmed; Wahsh, Marwa; Salah, Tarek; Geis-Gerstorfer, Jürgen

    2017-12-11

    The purpose of this in vitro study was to assess the effect of varying the margin designs and the occlusal thicknesses on the fracture resistance and mode of failures of endodontically treated teeth restored with polymer infiltrated ceramic endocrown restorations. Root canal treated mandibular molars were divided into four groups (n=8) and were prepared to receive Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) fabricated polymer infiltrated ceramic endocrowns (ENAMIC blocks). Group B2 represents teeth prepared with a butt joint design receiving endocrowns with 2mm occlusal thickness and the same for group B3.5 but with 3.5mm occlusal thickness. Group S2 represents teeth prepared with 1mm shoulder finish line receiving endocrowns with 2mm occlusal thickness and the same for group S3.5 but with 3.5mm occlusal thickness. After cementation and thermal aging, fracture resistance test was performed and failure modes were observed. Group S3.5 showed the highest mean fracture load value (1.27±0.31kN). Endocrowns with shoulder finish line had significantly higher mean fracture resistance values than endocrowns with butt margin (p<0.05). However, the results were not statistically significant regarding the restoration thickness. Evaluation of the fracture modes revealed no statistically significant difference between the modes of failure of tested groups. For the restoration of endodontically treated teeth, adding a short axial wall and shoulder finish line can increase the fracture resistance. However, further investigations, especially the fatigue behavior, are needed to ensure this effect applies with small increases of restoration thickness. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  14. Fracture resistance of premolar teeth restored with silorane-based or dimethacrylate-based composite resins.

    Science.gov (United States)

    Akbarian, Golsa; Ameri, Hamideh; Chasteen, Joseph E; Ghavamnasiri, Marjaneh

    2014-01-01

    To restore posterior teeth using low-shrinkage composite to minimize microleakage. To compare the fracture resistance of mesio-occlusal-distal (MOD) cavity preparations restored with either low-shrinkage composite or with dimethacrylate-based composite in conjunction with cavity liners and without them. The null hypothesis of the study is that there are no differences in either fracture resistance or fracture mode between the silorane group and dimethacrylate groups with and without the use of cavity liners. Sixty maxillary premolars were divided into six groups of 10. MOD cavities were prepared in four groups: F: posterior composite (Filtek P60); GF: 0.5-mm Glass Ionomer (Fuji LC) + posterior composite; FF: 0.5-mm flowable composite (Filtek Supreme XT) + posterior composite; and S: low-shrinkage composite (Filtek P90). Negative (N) and positive (P) control groups consisted of unrestored and sound teeth, respectively. The specimens were thermocycled and loaded. Data were analyzed using analysis of variance, Tukey, and chi-square tests (α = 0.05). Groups FF (1643.09 ± 187/80 N) and GF (1596.80 ± 163/93 N) (p = 0.06 > 0.05) were statistically identical, although less than group P (1742/33 ± 110/08 N), but still demonstrated greater fracture resistance than the other groups. The fracture resistance of group S (1434/69 ± 107/62 N) was identical to GF and FF (p = 0.06 > 0.05). The fracture resistance of F (1353/19 ± 233/90 N) was less than GF and FF, and statistically identical to S (p = 0.87 > 0.05). Silorane-based composite showed a resistance to fracture similar to methacrylate-based composite restorations regardless of whether cavity liners were used. The findings of this study support the selection of silorane-based composite for the restoration of maxillary premolars with standardized Class II cavity preparations in order to strengthen the resistance to fracture to the same extent as do dimethacrylate

  15. Paediatric talus fracture.

    LENUS (Irish Health Repository)

    Byrne, Ann-Maria

    2012-01-01

    Paediatric talus fractures are rare injuries resulting from axial loading of the talus against the anterior tibia with the foot in dorsiflexion. Skeletally immature bone is less brittle, with higher elastic resistance than adult bone, thus the paediatric talus can sustain higher forces before fractures occur. However, displaced paediatric talus fractures and those associated with high-energy trauma have been associated with complications including avascular necrosis, arthrosis, delayed union, neurapraxia and the need for revision surgery. The authors present the rare case of a talar neck fracture in a skeletally immature young girl, initially missed on radiological review. However, clinical suspicion on the part of the emergency physician, repeat examination and further radiographic imaging revealed this rare paediatric injury.

  16. Fracture resistance of reattached incisor fragments with mini fibre-reinforced composite anchors.

    NARCIS (Netherlands)

    Fennis, W.M.M.; Kreulen, C.M.; Wolke, J.G.C.; Fokkinga, W.A.; Machado, C.; Creugers, N.H.J.

    2009-01-01

    OBJECTIVES: Fractured coronal fragments of incisors can be adhered to the remaining tooth with resin composite, but are prone to failure. This study explores whether mini fibre-reinforced composite (FRC) anchors increase fracture resistance of reattached fragments. METHODS: Forty-five extracted

  17. Fracture Resistance of Lithium Disilicate Ceramics Bonded to Enamel or Dentin Using Different Resin Cement Types and Film Thicknesses.

    Science.gov (United States)

    Rojpaibool, Thitithorn; Leevailoj, Chalermpol

    2017-02-01

    To investigate the influence of cement film thickness, cement type, and substrate (enamel or dentin) on ceramic fracture resistance. One hundred extracted human third molars were polished to obtain 50 enamel and 50 dentin specimens. The specimens were cemented to 1-mm-thick lithium disilicate ceramic plates with different cement film thicknesses (100 and 300 μm) using metal strips as spacers. The cements used were etch-and-rinse (RelyX Ultimate) and self-adhesive (RelyX U200) resin cements. Compressive load was applied on the ceramic plates using a universal testing machine, and fracture loads were recorded in Newtons (N). Statistical analysis was performed by multiple regression (p enamel showed the highest mean fracture load (MFL; 1591 ± 172.59 N). The RelyX Ultimate groups MFLs were significantly higher than the corresponding RelyX U200 groups (p enamel (p enamel. Reduced resin film thickness could reduce lithium disilicate restoration fracture. Etch-and-rinse resin cements are recommended for cementing on either enamel or dentin, compared with self-adhesive resin cement, for improved fracture resistance. © 2015 by the American College of Prosthodontists.

  18. Fracture resistance of class IV fiber-reinforced composite resin restorations: An in vitro study

    Directory of Open Access Journals (Sweden)

    P S Praveen Kumar

    2017-01-01

    Full Text Available Objectives: The aim of this study was to evaluate fracture resistance of incisal edge fractures (Class IV restored with a Glass Fiber-reinforced Composite (FRC. Materials and Methods: Twenty-four extracted sound maxillary central incisors were randomly divided into two groups. Group I (control contained untreated teeth. Samples in experimental groups II were prepared by cutting the incisal (one-third part of the crown horizontally and was subjected to enamel preparations, then restored with a Glass FRC. Fracture resistance was evaluated as Newton's for samples tested in a Hounsfield universal testing machine. Failure modes were examined microscopically. Results: Mean peak failure load (Newton's observed in Glass Fiber-reinforced Nanocomposite was 863.50 ± 76.12. The experimental group showed similar types of failure modes with the majority occurring as cohesive and mixed type. 58% of the teeth in Glass FRC group fractured below the cementoenamel junction. Conclusion: Using Fiber reinforced composite substructure under conventional composites in Class IV restorations, the fracture resistance of the restored incisal edge could be increased.

  19. Fracture resistance of upper central incisors restored with different posts and cores

    Directory of Open Access Journals (Sweden)

    Maryam Rezaei Dastjerdi

    2015-08-01

    Full Text Available Objectives To determine and compare the fracture resistance of endodontically treated maxillary central incisors restored with different posts and cores. Materials and Methods Forty-eight upper central incisors were randomly divided into four groups: cast post and core (group 1, fiber-reinforced composite (FRC post and composite core (group 2, composite post and core (group 3, and controls (group 4. Mesio-distal and bucco-lingual dimensions at 7 and 14 mm from the apex were compared to ensure standardization among the groups. Twelve teeth were prepared for crown restoration (group 4. Teeth in other groups were endodontically treated, decoronated at 14 mm from the apex, and prepared for posts and cores. Resin-based materials were used for cementation in groups 1 and 2. In group 3, composite was used directly to fill the post space and for core build-up. All samples were restored by standard metal crowns using glass ionomer cement, mounted at 135° vertical angle, subjected to thermomechanical aging, and then fractured using a universal testing machine. Kruskal-Wallis and Mann-Whitney U tests were used to analyze the data. Results Fracture resistance of the groups was as follows: Control (group 4 > cast post and core (group 1 > fiber post and composite core (group 2 > composite post and core (group 3. All samples in groups 2 and 3 fractured in restorable patterns, whereas most (58% in group 1 were non-restorable. Conclusions Within the limitations of this study, FRC posts showed acceptable fracture resistance with favorable fracture patterns for reconstruction of upper central incisors.

  20. Assessing edge cracking resistance in AHSS automotive parts by the Essential Work of Fracture methodology

    Science.gov (United States)

    Frómeta, D.; Tedesco, M.; Calvo, J.; Lara, A.; Molas, S.; Casellas, D.

    2017-09-01

    Lightweight designs and demanding safety requirements in automotive industry are increasingly promoting the use of Advanced High Strength Steel (AHSS) sheets. Such steels present higher strength (above 800 MPa) but lower ductility than conventional steels. Their great properties allow the reduction of the thickness of automobile structural components without compromising the safety, but also introduce new challenges to parts manufacturers. The fabrication of most cold formed components starts from shear cut blanks and, due to the lower ductility of AHSS, edge cracking problems can appear during forming operations, forcing the stop of the production and slowing down the industrial process. Forming Limit Diagrams (FLD) and FEM simulations are very useful tools to predict fracture problems in zones with high localized strain, but they are not able to predict edge cracking. It has been observed that the fracture toughness, measured through the Essential Work of Fracture (EWF) methodology, is a good indicator of the stretch flangeability in AHSS and can help to foresee this type of fractures. In this work, a serial production automotive component has been studied. The component showed cracks in some flanged edges when using a dual phase steel. It is shown that the conventional approach to explain formability, based on tensile tests and FLD, fails in the prediction of edge cracking. A new approach, based on fracture mechanics, help to solve the problem by selecting steel grades with higher fracture toughness, measured by means of EWF. Results confirmed that fracture toughness, in terms of EWF, can be readily used as a material parameter to rationalize cracking related problems and select AHSS with improved edge cracking resistance.

  1. Resistance of Bonded Composite Restorations on Fractures of Endodontically Treated Teeth

    Directory of Open Access Journals (Sweden)

    AR Daneshkazemi

    2005-01-01

    Full Text Available Introduction: This study was performed to evaluate the effect of dentine bonding agents and Glass Ionomer cement beneath composite restorations and its resistance on fractures of endodontically treated teeth. Material and Methods: Forty sound maxillary teeth were selected; ten of them for positive control, and on the rest, RCT and MOD cavity preparations were done with standard methods. Then, the teeth were divided to four groups: 1-Sound teeth for positive control. 2-Prepared without any restoration for negative control. 3-Prepared and restored with Vitrabond(3M, USA, Single bond(3M, USA and Z100(3M, USA resin composite. 4-Prepared and restored by Single bond and Z100 resin composite. Specimens were subjected to compressive load by Instron 8502 until fracture occurred. Results: Group 1 showed the highest resistance to compressive forces followed by group 4,3&2 respectively. ANOVA, t test and Chi-square tests indicated significant difference between all the groups. Conclusion: Use of dentine bonding agents and resin composite increases resistance of endodontically treated teeth to fractures more than teeth restored with sandwich of glass ionomer cements, dentine bonding agents and resin composite.

  2. Effects of fatigue induced damage on the longitudinal fracture resistance of cortical bone.

    Science.gov (United States)

    Fletcher, Lloyd; Codrington, John; Parkinson, Ian

    2014-07-01

    As a composite material, cortical bone accumulates fatigue microdamage through the repetitive loading of everyday activity (e.g. walking). The accumulation of fatigue microdamage is thought to contribute to the occurrence of fragility fractures in older people. Therefore it is beneficial to understand the relationship between microcrack accumulation and the fracture resistance of cortical bone. Twenty longitudinally orientated compact tension fracture specimens were machined from a single bovine femur, ten specimens were assigned to both the control and fatigue damaged groups. The damaged group underwent a fatigue loading protocol to induce microdamage which was assessed via fluorescent microscopy. Following fatigue loading, non-linear fracture resistance tests were undertaken on both the control and damaged groups using the J-integral method. The interaction of the crack path with the fatigue induced damage and inherent toughening mechanisms were then observed using fluorescent microscopy. The results of this study show that fatigue induced damage reduces the initiation toughness of cortical bone and the growth toughness within the damage zone by three distinct mechanisms of fatigue-fracture interaction. Further analysis of the J-integral fracture resistance showed both the elastic and plastic component were reduced in the damaged group. For the elastic component this was attributed to a decreased number of ligament bridges in the crack wake while for the plastic component this was attributed to the presence of pre-existing fatigue microcracks preventing energy absorption by the formation of new microcracks.

  3. Effect of length and diameter of fiber reinforced composite post (FRC on fracture resistance of remaining tooth structure

    Directory of Open Access Journals (Sweden)

    Mahdiyeh seifi

    2013-03-01

    Full Text Available Introduction: Post and core has been considered for endodontically treated tooth, especially in cases with severe damage crowns. Recently fiber reinforced composite posts (FRC post have been used in the treatment of endodontically treated teeth. Because the length and diameter of posts are effective in stress distribution, the purpose of this study is to evaluate the effect of length and diameter of FRC post on fracture resistance. Methods: In this experimental study, 36 glass fiber posts with combination of 7mm, 9mm, and 12mm length and 1.1mm, 1.3mm and 1.5mm diameter were divided into 9 groups of 4. These posts were cemented in root canals by Panavia. Samples were tested with 45° compressive forces for the evaluation of fracture resistance. Datas were analyzed using SPSS soft ware and One- way and Two-way ANOVA analyses. Results: Fracture resistance did not increase significantly with the effect of length and diameter simultaneously (P=0.85. Samples with 12mm length and 1.5mm diameter had the greatest fracture resistance (1023/33N±239/22. The minimum fracture resistance had occurred in post with 7mm length and 1.5mm diameter (503/13N ±69/18. Fracture resistance increased significantly by increasing the length and the same diameter. Conclusion: It can be concluded that fracture resistance is affected by the length and not the diameter of FRC post.

  4. The relationship between material fracture resistance and the kinetics of fracture in steel components

    International Nuclear Information System (INIS)

    Irvine, W.H.

    1978-01-01

    The conditions necessary for the onset of fast brittle fracture are reasonably well understood. However with increasing material ductility at normal engineering stress levels the effects of structure size and type of loading become more important and make the understanding of the behaviour of large structures and laboratory test pieces and their inter-relation, more difficult.By using Berry's concept of a fracture locus, it is shown that the crack size - stress level - material fracture resistance relationship, as typified for instance by the Griffith-Irwin formulae, is necessary and sufficient for defining the point at which fast brittle fracture occurs, but that in the case of fast ductile fracture it is not sufficient by itself and must be supplemented by a description of the unloading path of the structural system. Although the demarcation line between these two types of behaviour is seen to be dependent on stress level it can nevertheless provide a definition of brittle and ductile fracture in engineering structures. Berry's use of the Griffith equation to describe the separation of the crack tip material limits any practical use of his locus equation to stress levels that are low by present day engineering standards. Consideration is given to the use of relationships describing crack tip failure which are more appropriate for the ductilities and stress levels of current engineering interest. These equations explicitly involve the size of the crack tip perturbation and therefore allow a direct check to be made on validity. Examples are given of the application of these methods to describe fractures which have occurred in structural components. (author)

  5. Rectangular Schlumberger resistivity arrays for delineating vadose zone clay-lined fractures in shallow tuff

    International Nuclear Information System (INIS)

    Miele, M.; Laymon, D.; Gilkeson, R.; Michelotti, R.

    1996-01-01

    Rectangular Schlumberger arrays can be used for 2-dimensional lateral profiling of apparent resistivity at a unique current electrode separation, hence single depth of penetration. Numerous apparent resistivity measurements are collected moving the potential electrodes (fixed MN spacing) within a rectangle of defined dimensions. The method provides a fast, cost-effective means for the collection of dense resistivity data to provide high-resolution information on subsurface hydrogeologic conditions. Several rectangular Schlumberger resistivity arrays were employed at Los Alamos National Laboratory (LANL) from 1989 through 1995 in an area adjacent to and downhill from an outfall pipe, septic tank, septic drainfield, and sump. Six rectangular arrays with 2 AB spacings were used to delineate lateral low resistivity anomalies that may be related to fractures that contain clay and/or vadose zone water. Duplicate arrays collected over a three year time period exhibited very good data repeatability. The properties of tritium make it an excellent groundwater tracer. Because tritium was present in discharged water from all of the anthropogenic sources in the vicinity it was used for this purpose. One major low resistivity anomaly correlates with relatively high tritium concentrations in the tuff. This was determined from borehole samples collected within and outside of the anomalous zone. The anomaly is interpreted to be due to fractures that contain clay from the soil profile. The clay was deposited in the fractures by aeolian processes and by surface water infiltration. The fractures likely served as a shallow vadose zone groundwater pathway

  6. Fracture Resistance, Surface Defects and Structural Strength of Glass

    NARCIS (Netherlands)

    Rodichev, Y.M.; Veer, F.A.

    2010-01-01

    This paper poses the theory that the fracture resistance of basic float glass is dependent on it physicochemical properties and the surface defects fonned under the float glass production, glass processing and handling at the service conditions compose the aggregate basis for structural glass

  7. Fracture resistance of metal-free composite crowns-effects of fiber reinforcement, thermal cycling, and cementation technique.

    Science.gov (United States)

    Lehmann, Franziska; Eickemeyer, Grit; Rammelsberg, Peter

    2004-09-01

    The improved mechanical properties of contemporary composites have resulted in their extensive use for the restoration of posterior teeth. However, the influence of fiber reinforcement, cementation technique, and physical stress on the fracture resistance of metal-free crowns is unknown. This in vitro study evaluated the effect of fiber reinforcement, physical stress, and cementation methods on the fracture resistance of posterior metal-free Sinfony crowns. Ninety-six extracted human third molars received a standardized tooth preparation: 0.5-mm chamfer preparation and occlusal reduction of 1.3 to 1.5 mm. Sinfony (nonreinforced crowns, n=48) and Sinfony-Vectris (reinforced crowns, n=48) crowns restoring original tooth contour were prepared. Twenty-four specimens of each crown type were cemented, using either glass ionomer cement (GIC) or resin cement. Thirty-two crowns (one third) were stored in humidity for 48 hours. Another third was exposed to 10,000 thermal cycles (TC) between 5 degrees C and 55 degrees C. The remaining third was treated with thermal cycling and mechanical loading (TCML), consisting of 1.2 million axial loads of 50 N. The artificial crowns were then vertically loaded with a steel sphere until failure occurred. Significant differences in fracture resistance (N) between experimental groups were assessed by nonparametric Mann-Whitney U-test (alpha=.05). Fifty percent of the Sinfony and Sinfony-Vectris crowns cemented with glass ionomer cement loosened after thermal cycling. Thermal cycling resulted in a significant reduction in the mean fracture resistance for Sinfony crowns cemented with GIC, from 2037 N to 1282 N (P=.004). Additional fatigue produced no further effects. Fiber reinforcement significantly increased fracture resistance, from 1555 N to 2326 N (P=.001). The minimal fracture resistance was above 600 N for all combinations of material, cement and loading. Fracture resistance of metal-free Sinfony crowns was significantly increased by

  8. In Vitro Evaluation of the Effect of Tooth Structure Loss on Fracture Resistance of Endodontically Treated Teeth

    Directory of Open Access Journals (Sweden)

    Shirinzad M

    2017-06-01

    Full Text Available Introduction: Since preserving the structure of treated teeth is a critical success factor, studying the effects of tooth structure loss on fracture resistance of the tooth tissue appears necessary. The aim of this study was to evaluate the consequences of the loss of different tissues regarding fracture resistance of teeth undergoing root canal treatment without the use of indirect restorations. Methods :In this experimental study, 70 healthy maxillary first premolar teeth were randomly divided into 7 groups of 10 members, including control group, endodontic access preparation only, MOD cavity preparation, cutting buccal cusp, cutting palatal cusp, cutting buccal cusp and marginal ridge, and cutting the palatal cusp and marginal ridge. The coronal section of teeth was restored incrementally with light cure composite. Finally, samples underwent compressive load with 45˚ angle from each cusp slope in the middle of cusp with an instant speed of 1 mm per min in the Instron machine. Fracture resistance was measured and samples were examined under stereo-microscope to evaluate the mode of failure. Results: The resistance to fracture in root canal treated teeth in different groups in order from first to seventh was 797.13 ± 52.92, 722.50 ± 131.40, 432.15 ± 203.20, 592.66 ± 195.86 124.53 ± 33.09, 85.17 ± 18.45, and 26.03 ± 5.21 Newton. ANOVA test showed statistically significant differences between the groups in terms of their fracture resistance (P = 0.000. Conclusions: The results showed that fracture resistance levels of teeth were significantly affected by amount of their tissue loss. In this study, removal of teeth palatal cusp and marginal ridge had a significant effect on decreasing the fracture resistance, while removing the buccal cusps alone cannot have a significant effect.

  9. Imaging Pathways in Fractured Rock Using Three-Dimensional Electrical Resistivity Tomography.

    Science.gov (United States)

    Robinson, Judith; Slater, Lee; Johnson, Timothy; Shapiro, Allen; Tiedeman, Claire; Ntarlagiannis, Dimitrios; Johnson, Carole; Day-Lewis, Frederick; Lacombe, Pierre; Imbrigiotta, Thomas; Lane, John

    2016-03-01

    Major challenges exist in delineating bedrock fracture zones because these cause abrupt changes in geological and hydrogeological properties over small distances. Borehole observations cannot sufficiently capture heterogeneity in these systems. Geophysical techniques offer the potential to image properties and processes in between boreholes. We used three-dimensional cross borehole electrical resistivity tomography (ERT) in a 9 m (diameter) × 15 m well field to capture high-resolution flow and transport processes in a fractured mudstone contaminated by chlorinated solvents, primarily trichloroethylene. Conductive (sodium bromide) and resistive (deionized water) injections were monitored in seven boreholes. Electrode arrays with isolation packers and fluid sampling ports were designed to enable acquisition of ERT measurements during pulsed tracer injections. Fracture zone locations and hydraulic pathways inferred from hydraulic head drawdown data were compared with electrical conductivity distributions from ERT measurements. Static ERT imaging has limited resolution to decipher individual fractures; however, these images showed alternating conductive and resistive zones, consistent with alternating laminated and massive mudstone units at the site. Tracer evolution and migration was clearly revealed in time-lapse ERT images and supported by in situ borehole vertical apparent conductivity profiles collected during the pulsed tracer test. While water samples provided important local information at the extraction borehole, ERT delineated tracer migration over spatial scales capturing the primary hydrogeological heterogeneity controlling flow and transport. The fate of these tracer injections at this scale could not have been quantified using borehole logging and/or borehole sampling methods alone. © 2015, National Ground Water Association.

  10. Imaging pathways in fractured rock using three-dimensional electrical resistivity tomography

    Science.gov (United States)

    Robinson, Judith; Slater, Lee; Johnson, Timothy B.; Shapiro, Allen M.; Tiedeman, Claire; Ntlargiannis, Dimitrios; Johnson, Carole D.; Day-Lewis, Frederick D.; Lacombe, Pierre; Imbrigiotta, Thomas; Lane, John W.

    2016-01-01

    Major challenges exist in delineating bedrock fracture zones because these cause abrupt changes in geological and hydrogeological properties over small distances. Borehole observations cannot sufficiently capture heterogeneity in these systems. Geophysical techniques offer the potential to image properties and processes in between boreholes. We used three-dimensional cross borehole electrical resistivity tomography (ERT) in a 9 m (diameter) × 15 m well field to capture high-resolution flow and transport processes in a fractured mudstone contaminated by chlorinated solvents, primarily trichloroethylene. Conductive (sodium bromide) and resistive (deionized water) injections were monitored in seven boreholes. Electrode arrays with isolation packers and fluid sampling ports were designed to enable acquisition of ERT measurements during pulsed tracer injections. Fracture zone locations and hydraulic pathways inferred from hydraulic head drawdown data were compared with electrical conductivity distributions from ERT measurements. Static ERT imaging has limited resolution to decipher individual fractures; however, these images showed alternating conductive and resistive zones, consistent with alternating laminated and massive mudstone units at the site. Tracer evolution and migration was clearly revealed in time-lapse ERT images and supported by in situ borehole vertical apparent conductivity profiles collected during the pulsed tracer test. While water samples provided important local information at the extraction borehole, ERT delineated tracer migration over spatial scales capturing the primary hydrogeological heterogeneity controlling flow and transport. The fate of these tracer injections at this scale could not have been quantified using borehole logging and/or borehole sampling methods alone.

  11. Fracture resistance of 3 types of primary esthetic stainless steel crowns.

    Science.gov (United States)

    Beattie, Sean; Taskonak, Burak; Jones, James; Chin, Judith; Sanders, Brian; Tomlin, Angela; Weddell, James

    2011-01-01

    Demand is increasing for esthetic restorations in pediatric dentistry. When full coverage is indicated, one option is to use esthetic stainless steel crowns (SSCs). However, this type of crown is prone to fracture. The purpose of this study was to evaluate the fracture resistance of 3 types of esthetic SSCs. Esthetic SSCs for first primary mandibular molars were cemented to idealized epoxy dies with glass ionomer cement. The die-crown units were fractured on a universal testing machine. The force was delivered by a stainless steel ball fixture, set in a uniaxial lever to replicate a cusp contact, with a crosshead speed of 1 mm/min. The differences among the 3 types of crown, in terms of force required to fracture, were compared statistically by 1-way analysis of variance. Pairwise comparisons were performed with Fisher's protected least significant difference test, at an overall significance level of 5%. The force required to fracture, expressed as average ± standard error, did not differ significantly among the 3 brands of esthetic SSCs: 1730 N ± 50 N, 1826 N ± 62 N and 1671 N ± 68 N, respectively (p = 0.19), well below the maximum bite force of pediatric patients determined in a previous study. Esthetic SSCs should be able to resist occlusal forces over short clinical periods. However, long-term occlusal loading and fatigue failures should be taken into account when evaluating the success of this type of crown.

  12. Evaluation of the fracture resistance of computer-aided design/computer-aided manufacturing monolithic crowns prepared in different cement thicknesses.

    Science.gov (United States)

    Sagsoz, N Polat; Yanıkoglu, N

    2018-04-01

    The purpose of this study was to evaluate the fracture resistance of monolithic computer-aided design/computer-aided manufacturing (CAD/CAM) crowns that are prepared with different cement thickness. For this investigation, a human maxillary premolar tooth was selected. Master model preparation was performed with a demand bur under water spray. Master die was taken to fabricate 105 epoxy resin replicas. The crowns were milled using a CEREC 4 CAD/CAM system (Software Version, 4.2.0.57192). CAD/CAM crowns were made using resin nanoceramic, feldspathic glass ceramic, lithium disilicate, and leucite-reinforced ceramics. Each group was subdivided into three groups in accordance with three different cement thicknesses (30, 90, and 150 μm). Crowns milled out. Then RelyX ™ U200 was used as a luting agent to bond the crowns to the prepared samples. After one hour cementations, the specimens were stored in water bath at 37°C for 1 week before testing. Seven unprepared and unrestored teeth were kept and tested as a control group. A universal test machine was used to assume the fracture resistance of all specimens. The compressive load (N) that caused fracture was recorded for each specimen. Fracture resistance data were statistically analyzed by one-way ANOVA and two-factor interaction modeling test (α = 0.001). There are statistically significant differences between fracture resistances of CAD/CAM monolithic crown materials (P cement thickness is not statistically significant for fracture resistance of CAD/CAM monolithic crowns (P > 0.001). CAD/CAM monolithic crown materials affected fracture resistance. Cement thickness (30, 90, and 150 μm) was not effective on fracture resistance of CAD/CAM monolithic crowns.

  13. Mixture for producing fracture-resistant, fiber-reinforced ceramic material by microwave heating

    Science.gov (United States)

    Meek, T.T.; Blake, R.D.

    1985-04-03

    A fracture-resistant, fiber-reinforced ceramic substrate is produced by a method which involves preparing a ceramic precursor mixture comprising glass material, a coupling agent, and resilient fibers, and then exposing the mixture to microwave energy. The microwave field orients the fibers in the resulting ceramic material in a desired pattern wherein heat later generated in or on the substrate can be dissipated in a desired geometric pattern parallel to the fiber pattern. Additionally, the shunt capacitance of the fracture-resistant, fiber-reinforced ceramic substrate is lower which provides for a quicker transit time for electronic pulses in any conducting pathway etched into the ceramic substrate.

  14. A multi-packer technique for investigating resistance to flow through fractured rock and illustrative results

    International Nuclear Information System (INIS)

    Bourke, P.J.; Rae, J.

    1981-01-01

    A multi-packer technique was used to locate twelve discrete fractures in the lower half of a 200 m deep drill hole in Cornish granite. The resistances to water flows into these fractures both singly and together were measured. Geological explanations of the results obtained were sought by examination of core from the hole. Analysis of the results and the further data needed and now being sought to determine resistance to flow over long distances through the pattern of interconnected fractures are discussed. This information is required for the assessment of the safety of burial of radioactive wastes

  15. Fracture Resistance of Implant Abutments Following Abutment Alterations by Milling the Margins: An In Vitro Study.

    Science.gov (United States)

    Patankar, Anuya; Kheur, Mohit; Kheur, Supriya; Lakha, Tabrez; Burhanpurwala, Murtuza

    2016-12-01

    This in vitro study evaluated the effect of different levels of preparation of an implant abutment on its fracture resistance. The study evaluated abutments that incorporated a platform switch (Myriad Plus Abutments, Morse Taper Connection) and Standard abutments (BioHorizons Standard Abutment, BioHorizons Inc). Each abutment was connected to an appropriate implant and mounted in a self-cured resin base. Based on the abutment preparation depths, 3 groups were created for each abutment type: as manufactured, abutment prepared 1 mm apical to the original margin, and abutment prepared 1.5 mm to the original margin. All the abutments were prepared in a standardized manner to incorporate a 0.5 mm chamfer margin uniformly. All the abutments were torqued to 30 Ncm on their respective implants. They were then subjected to loading until failure in a universal testing machine. Abutments with no preparation showed the maximum resistance to fracture for both groups. As the preparation depth increased, the fracture resistance decreased. The fracture resistance of implant abutment junction decreases as the preparation depth increases.

  16. Increase in cellular concrete resistance to brittle fracture

    International Nuclear Information System (INIS)

    Chernyshov, E.M.; Krokhin, A.M.

    1979-01-01

    Considered are theoretical premises of decrease in cellular concrete resistance to brittle fracture at the expense of dispersed reinforcement. It is stated experimentally that the introduction of 3% asbestos fibers permits to increase the ultimate extensibility and strength during cellular concrete tension by 15-30% and to increase in unit rupture work 1.4-1.6 time more and therefore to decrease its brittleness

  17. Fracture properties and heat resistance of ceramics consisting of microspheres of stabilized zirconium dioxide

    International Nuclear Information System (INIS)

    Krasulin, Yu.L.; Barinov, S.M.; Ivanov, A.B.; Timofeev, V.N.; Grevtsev, S.N.; Ivanov, D.A.

    1980-01-01

    Determined were effective specific fracture work, critical coefficient of stress intensity in the upper point of the fracture, strength and heat resistance during heat changes (20-1300 deg C) of the material produced by sintering stabilized zirconium dioxide microspheres. Dependence of these characteristics on granulometric composition of microspheres was determined. It was ascertained that the additional introduction of large microspheres into the bulk of small microspheres increased the metal fracture work. Specific work of material fracture progress exceeded specific work of fracture motion initiation. High value of fracture work together with high strength permits to use the material formed of microspheres as structural ceramics

  18. Characterisation of Fractures and Fracture Zones in a Carbonate Aquifer Using Electrical Resistivity Tomography and Pricking Probe Methodes

    Science.gov (United States)

    Szalai, Sandor; Kovacs, Attila; Kuslits, Lukács; Facsko, Gabor; Gribovszki, Katalin; Kalmar, Janos; Szarka, Laszlo

    2018-04-01

    Position, width and fragmentation level of fracture zones and position, significance and characteristic distance of fractures were aimed to determine in a carbonate aquifer. These are fundamental parameters, e.g. in hydrogeological modelling of aquifers, due to their role in subsurface water movements. The description of small scale fracture systems is however a challenging task. In the test area (Kádárta, Bakony Mts, Hungary), two methods proved to be applicable to get reasonable information about the fractures: Electrical Resistivity Tomography (ERT) and Pricking-Probe (PriP). PriP is a simple mechanical tool which has been successfully applied in archaeological investigations. ERT results demonstrated its applicability in this small scale fracture study. PriP proved to be a good verification tool both for fracture zone mapping and detecting fractures, but in certain areas, it produced different results than the ERT. The applicability of this method has therefore to be tested yet, although its problems most probably origin from human activity which reorganises the near-surface debris distribution. In the test site, both methods displayed fracture zones including a very characteristic one and a number of individual fractures and determined their characteristic distance and significance. Both methods prove to be able to produce hydrogeologically important parameters even individually, but their simultaneous application is recommended to decrease the possible discrepancies.

  19. Fracture resistance of endodontically-treated teeth: effect of combination bleaching and an antioxidant.

    Science.gov (United States)

    Khoroushi, Maryam; Feiz, Atieh; Khodamoradi, Roghayeh

    2010-01-01

    This in vitro study assessed the fracture resistance of endodontically-treated teeth undergoing combination bleaching with 38% and 9.5% hydrogen peroxide gels as in-office and at-home bleaching techniques, respectively. In addition, the effect of an antioxidizing agent, sodium ascorbate, was investigated. Sixty maxillary premolars were endodontically-treated, received a glass ionomer barrier as a mechanical seal and were embedded in acrylic resin up to the cemento-enamel junction. The specimens were divided into four groups (n = 15) as follows: G I: no bleaching, access cavity restored with resin composite (negative control); G II: bleached for three weeks daily using 9.5% hydrogen peroxide for two hours and three sessions of in-office bleaching using 38% hydrogen peroxide every seven days, then restored (positive control); G III: bleached similar to G II and restored after one week; G IV: bleached similar to G II, along with the use of an antioxidizing agent for 24 hours, then restored. In each in-office and at-home bleaching session, the whitening gels were applied to the buccal surface of the tooth and placed inside the pulp chamber (inside/outside bleaching technique). Finally, the specimens underwent fracture resistance testing; the data were analyzed using ANOVA and Scheffé's test (alpha = 0.05). Significant differences were observed among the study groups (p 0.05). Within the limitations of the current study, it can be concluded that the fracture resistance of endodontically-treated teeth decreases after combination bleaching. The use of sodium ascorbate can reverse decreased fracture resistance.

  20. Effect of Processing Conditions on Fracture Resistance and Cohesive Laws of Binderfree All-Cellulose Composites

    DEFF Research Database (Denmark)

    Goutianos, Stergios; Arévalo, R.; Sørensen, Bent F.

    2014-01-01

    molecules during the drying process. Defibrilation of the raw cellulose material is done in wet medium in a paper-like process. Panels with different refining time were tested and it was found than an increase in fibre fibrillation results in a lower fracture resistance. © 2014 Springer Science......The fracture properties of all-cellulose composites without matrix were studied using Double Cantilever Beam (DCB) sandwich specimens loaded with pure monotonically increasing bending moments, which give stable crack growth. The experiments were conducted in an environmental scanning electron...... microscope to a) perform accurate measurements of both the fracture energy for crack initiation and the fracture resistance and b) observe the microscale failure mechanisms especially in the the wake of the crack tip. Since the mechanical behaviour of the all-cellulose composites was non-linear, a general...

  1. Fracture Resistance of Endodontically Treated Teeth Restored with 2 Different Fiber-reinforced Composite and 2 Conventional Composite Resin Core Buildup Materials: An In Vitro Study.

    Science.gov (United States)

    Eapen, Ashly Mary; Amirtharaj, L Vijay; Sanjeev, Kavitha; Mahalaxmi, Sekar

    2017-09-01

    The purpose of this in vitro study was to comparatively evaluate the fracture resistance of endodontically treated teeth restored with 2 fiber-reinforced composite resins and 2 conventional composite resin core buildup materials. Sixty noncarious unrestored human maxillary premolars were collected, endodontically treated (except group 1, negative control), and randomly divided into 5 groups (n = 10). Group 2 was the positive control. The remaining 40 prepared teeth were restored with various direct core buildup materials as follows: group 3 teeth were restored with dual-cure composite resin, group 4 with posterior composite resin, group 5 with fiber-reinforced composite resin, and group 6 with short fiber-reinforced composite resin. Fracture strength testing was performed using a universal testing machine. The results were statistically analyzed by 1-way analysis of variance and the post hoc Tukey test. Fracture patterns for each sample were also examined under a light microscope to determine the level of fractures. The mean fracture resistance values (in newtons) were obtained as group 1 > group 6 > group 4 > group 3 > group 5 > group 2. Group 6 showed the highest mean fracture resistance value, which was significantly higher than the other experimental groups, and all the fractures occurred at the level of enamel. Within the limitations of this study, a short fiber-reinforced composite can be used as a direct core buildup material that can effectively resist heavy occlusal forces against fracture and may reinforce the remaining tooth structure in endodontically treated teeth. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. Rib fractures and their association With solid organ injury: higher rib fractures have greater significance for solid organ injury screening.

    Science.gov (United States)

    Rostas, Jack W; Lively, Timothy B; Brevard, Sidney B; Simmons, Jon D; Frotan, Mohammad A; Gonzalez, Richard P

    2017-04-01

    The purpose of this study was to identify patients with rib injuries who were at risk for solid organ injury. A retrospective chart review was performed of all blunt trauma patients with rib fractures during the period from July 2007 to July 2012. Data were analyzed for association of rib fractures and solid organ injury. In all, 1,103 rib fracture patients were identified; 142 patients had liver injuries with 109 (77%) associated right rib fractures. Right-sided rib fractures with highest sensitivity for liver injury were middle rib segment (5 to 8) and lower segment (9 to 12) with liver injury sensitivities of 68% and 43%, respectively (P rib fractures. Left middle segment rib fractures and lower segment rib fractures had sensitivities of 80% and 63% for splenic injury, respectively (P Rib fractures higher in the thoracic cage have significant association with solid organ injury. Using rib fractures from middle plus lower segments as indication for abdominal screening will significantly improve rib fracture sensitivity for identification of solid organ injury. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Fracture resistance of endodontically treated permanent anterior teeth restored with three different esthetic post systems: An in vitro study

    Directory of Open Access Journals (Sweden)

    Ameet J Kurthukoti

    2015-01-01

    Full Text Available Background: Esthetic coronal reconstruction of fractured anterior teeth is often performed using intra radicular posts. Most of the commonly used commercially esthetic post systems do not exhibit similar physical properties as dentin resulting in failures. Aim: To evaluate and compare the fracture resistance and mode of failure of simulated traumatized permanent central incisors restored with three different post systems including biologic dentin posts. Materials and Methods: A total of 40 recently extracted human maxillary central incisors with similar dimensions were decoronated 2 mm above the cemento-enamel junction and endodontically treated. Ten specimens were randomly selected as the Group I - Control group (core built teeth without intraradicular posts. The remaining 30 teeth were equally divided and restored with zirconia (Group II, n = 10, fiber re-inforced composite (FRC (Group III, n = 10 and biologic dentin posts (Group IV, n = 10 using resin bonded cement and their cores built-up. These samples were embedded in acrylic resin and then secured in a Universal Testing Machine and subjected to fracture resistance testing. The location of failure in the specimens was evaluated using a stereomicroscope. Results: Intergroup comparison revealed that the control group and zirconia post group (522 ± 110 N demonstrated the least fracture resistance, while dentin post group (721 ± 127 N the highest. There was no statistically significant difference between fiber post and dentin post groups. Fractures that were repairable were observed in fiber post and dentin post groups, whereas mostly unrestorable, catastrophic fractures were observed in the zirconia post group. Conclusion: Teeth restored with the biologic dentin post system demonstrated the highest fracture resistance and repairable fractures, closely followed by FRC post system. The least fracture resistance and most catastrophic fractures were demonstrated by the zirconia post system.

  4. Fracture Resistance and Mode of Failure of Ceramic versus Titanium Implant Abutments and Single Implant-Supported Restorations.

    Science.gov (United States)

    Sghaireen, Mohd G

    2015-06-01

    The material of choice for implant-supported restorations is affected by esthetic requirements and type of abutment. This study compares the fracture resistance of different types of implant abutments and implant-supported restorations and their mode of failure. Forty-five Oraltronics Pitt-Easy implants (Oraltronics Dental Implant Technology GmbH, Bremen, Germany) (4 mm diameter, 10 mm length) were embedded in clear autopolymerizing acrylic resin. The implants were randomly divided into three groups, A, B and C, of 15 implants each. In group A, titanium abutments and metal-ceramic crowns were used. In group B, zirconia ceramic abutments and In-Ceram Alumina crowns were used. In group C, zirconia ceramic abutments and IPS Empress Esthetic crowns were used. Specimens were tested to failure by applying load at 130° from horizontal plane using an Instron Universal Testing Machine. Subsequently, the mode of failure of each specimen was identified. Fracture resistance was significantly different between groups (p Empress crowns supported by zirconia abutments had the lowest fracture loads (p = .000). Fracture modes of metal-ceramic crowns supported by titanium abutments included screw fracture and screw bending. Fracture of both crown and abutment was the dominant mode of failure of In-Ceram/IPS Empress crowns supported by zirconia abutments. Metal-ceramic crowns supported by titanium abutments were more resistant to fracture than In-Ceram crowns supported by zirconia abutments, which in turn were more resistant to fracture than IPS Empress crowns supported by zirconia abutments. In addition, failure modes of restorations supported by zirconia abutments were more catastrophic than those for restorations supported by titanium abutments. © 2013 Wiley Periodicals, Inc.

  5. Effects of microstructures and creep conditions on the fractal dimension of grain boundary fracture in high-temperature creep of heat-resistant alloys

    International Nuclear Information System (INIS)

    Tanaka, Manabu

    1993-01-01

    The effects of microstructural aspects, such as grain size and grain boundary configuration, and creep conditions on the fractal dimension of the grain boundary fracture were examined using several heat-resistant alloys, principally in an analysis scale range between one grain boundary length and specimen size. Grain boundary fracture surface profiles in the heat-resistant alloys exhibited a fractal nature in the scale range between one grain boundary length and specimen size as well as in the scale range below one grain boundary length. The fractal dimension of the grain boundary fracture slightly increased with decreasing grain size and was generally a little larger in the specimens with serrated grain boundaries than in those with straight grain boundaries. The fractal dimension of the grain boundary and the number of grain boundary microcracks which affected the grain boundary fracture patterns were a little larger in the specimen with the smaller grain size, and were also larger in the specimen with serrated grain boundaries. The fractal dimension of the grain boundary fracture increased with decreasing creep stress in the temperature range from 973 to 1422 K in these alloys, since more grain boundary microcracks existed in the specimens ruptured under the lower stresses at the higher temperatures. (orig.) [de

  6. A comparison of resistance to fracture among four commercially available forms of hydroxyapatite cement.

    Science.gov (United States)

    Miller, Lee; Guerra, Aldo Benjamin; Bidros, Rafi Sirop; Trahan, Christopher; Baratta, Richard; Metzinger, Stephen Eric

    2005-07-01

    Hydroxyapatite cement is a relatively new biomaterial that has found widespread use in craniomaxillofacial surgery. Despite its common usage, complication rates as high as 32% have been reported. When failed implants are removed, implant fracture has been cited as a potential cause of failure. The purpose of this study was to evaluate resistance to fracture among 4 commercially available hydroxyapatite cement formulations. The materials tested included Norian Craniofacial Repair System (carbonated apatite cement) (AO North America, Devon, PA), Norian CRS Fast Set Putty (carbonated apatite cement) (AO North America), BoneSource (hydroxyapatite cement) (Stryker Leibinger, Portage, MI), and Mimix (hydroxyapatite cement) (Walter Lorenz Surgical, Inc, Jacksonville, FL). To ensure consistency, all materials were embedded in acrylic wells. Each material was placed into a well 2.54 cm in diameter and 0.953 cm in thickness. The materials were prepared per manufacturer specifications. All materials were incubated at 37.0 degrees C, in 6% CO2, 100% humidity for 36 hours. Using the Bionix MTS Test System, a 12-mm-diameter probe applied incremental force to the center of the disk at a rate of 0.1 mm per second. The transmitted force was measured using a Bionix MTS Axial-Torsional Load Transducer for each disk. The force which resulted in fracture was recorded for each material. Ten disks of each material were processed by this method, for a total of 40 disks. The significance of resistance to fracture for the 4 compounds was analyzed using 1-way analysis of variance with post hoc Scheffe method. Mean fracture force with related P values was plotted for direct comparison of group outcomes. Material type contributed significantly to variance in fracture force for the biomaterials studied. Norian CRS required the greatest mean fracture force (1385 N, SD+/-292 N), followed by Norian CRS Fast Set Putty (1143 N, SD+/-193 N). Mimix required a mean fracture force of 740 N, SD+/-79 N

  7. Potential Explanatory Factors for Higher Incident Hip Fracture Risk in Older Diabetic Adults

    Directory of Open Access Journals (Sweden)

    Elsa S. Strotmeyer

    2011-01-01

    Full Text Available Type 2 diabetes is associated with higher fracture risk. Diabetes-related conditions may account for this risk. Cardiovascular Health Study participants (N=5641; 42.0% men; 15.5% black; 72.8±5.6 years were followed 10.9 ± 4.6 years. Diabetes was defined as hypoglycemic medication use or fasting glucose (FG ≥126 mg/dL. Peripheral artery disease (PAD was defined as ankle-arm index <0.9. Incident hip fractures were from medical records. Crude hip fracture rates (/1000 person-years were higher for diabetic vs. non-diabetic participants with BMI <25 (13.6, 95% CI: 8.9–20.2 versus 11.4, 95% CI: 10.1–12.9 and BMI ≥25 to <30 (8.3, 95% CI: 5.7–11.9 versus 6.6, 95% CI: 5.6–7.7, but similar for BMI ≥30. Adjusting for BMI, sex, race, and age, diabetes was related to fractures (HR = 1.34; 95% CI: 1.01–1.78. PAD (HR = 1.25 (95% CI: 0.92–1.57 and longer walk time (HR = 1.07 (95% CI: 1.04–1.10 modified the fracture risk in diabetes (HR = 1.17 (95% CI: 0.87–1.57. Diabetes was associated with higher hip fracture risk after adjusting for BMI though this association was modified by diabetes-related conditions.

  8. Fracture resistance of endodontically treated teeth restored with a bulkfill flowable material and a resin composite.

    Science.gov (United States)

    Isufi, Almira; Plotino, Gianluca; Grande, Nicola Maria; Ioppolo, Pietro; Testarelli, Luca; Bedini, Rossella; Al-Sudani, Dina; Gambarini, Gianluca

    2016-01-01

    To determine and compare the fracture resistance of endodontically treated teeth restored with a bulk fill flowable material (SDR) and a traditional resin composite. Thirty maxillary and 30 mandibular first molars were selected based on similar dimensions. After cleaning, shaping and filling of the root canals and adhesive procedures, specimens were assigned to 3 subgroups for each tooth type (n=10): Group A: control group, including intact teeth; Group B: access cavities were restored with a traditional resin composite (EsthetX; Dentsply-Italy, Rome, Italy); Group C: access cavities were restored with a bulk fill flowable composite (SDR; Dentsply-Italy), except 1.5 mm layer of the occlusal surface that was restored with the same resin composite as Group B. The specimens were subjected to compressive force in a material static-testing machine until fracture occurred, the maximum fracture load of the specimens was measured (N) and the type of fracture was recorded as favorable or unfavorable. Data were statistically analyzed with one-way analysis of variance (ANOVA) and Bonferroni tests (Pcomposite and with a bulk fill flowable composite (SDR) was similar in both maxillary and mandibular molars and showed no significant decrease in fracture resistance compared to intact specimens. No significant difference was observed in the mechanical fracture resistance of endodontically treated molars restored with traditional resin composite restorations compared to bulk fill flowable composite restorations.

  9. Fracture strength and fatigue resistance of dental resin-based composites

    NARCIS (Netherlands)

    Keulemans, F.; Palav, P.; Aboushelib, M.M.N.; van Dalen, A.; Kleverlaan, C.J.; Feilzer, A.J.

    2009-01-01

    Objectives: The aim of this study was to evaluate in vitro the influence of fiber-reinforcement on the fracture strength and fatigue resistance of resin-based composites. Methods: One hundred rectangular bar-shaped specimens (2 mm × 2 mm × 25 mm) made of resin-based composite were prepared in a

  10. The significance of crack-resistance curves to the mixed-mode fracture toughness of human cortical bone

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, Elizabeth A.; Launey, Maximilien E.; Ritchie, Robert O.

    2010-03-25

    The majority of fracture mechanics studies on the toughness of bone have been performed under tensile loading. However, it has recently been shown that the toughness of human cortical bone in the transverse (breaking) orientation is actually much lower in shear (mode II) than in tension (mode I); a fact that is physiologically relevant as in vivo bone is invariably loaded multiaxially. Since bone is a material that derives its fracture resistance primarily during crack growth through extrinsic toughening mechanisms, such as crack deflection and bridging, evaluation of its toughness is best achieved through measurements of the crack-resistance or R-curve, which describes the fracture toughness as a function of crack extension. Accordingly, in this study, we attempt to measure for the first time the R-curve fracture toughness of human cortical bone under physiologically relevant mixed-mode loading conditions. We show that the resulting mixed-mode (mode I + II) toughness depends strongly on the crack trajectory and is the result of the competition between the paths of maximum mechanical driving force and 'weakest' microstructural resistance.

  11. Fracture toughness and crack growth resistance of pressure vessel plate and weld metal steels

    International Nuclear Information System (INIS)

    Moskovic, R.

    1988-01-01

    Compact tension specimens were used to measure the initiation fracture toughness and crack growth resistance of pressure vessel steel plates and submerged arc weld metal. Plate test specimens were manufactured from four different casts of steel comprising: aluminium killed C-Mn-Mo-Cu and C-Mn steel and two silicon killed C-Mn steels. Unionmelt No. 2 weld metal test specimens were extracted from welds of double V butt geometry having either the C-Mn-Mo-Cu steel (three weld joints) or one particular silicon killed C-Mn steel (two weld joints) as parent plate. A multiple specimen test technique was used to obtain crack growth data which were analysed by simple linear regression to determine the crack growth resistance lines and to derive the initiation fracture toughness values for each test temperature. These regression lines were highly scattered with respect to temperature and it was very difficult to determine precisely the temperature dependence of the initiation fracture toughness and crack growth resistance. The data were re-analysed, using a multiple linear regression method, to obtain a relationship between the materials' crack growth resistance and toughness, and the principal independent variables (temperature, crack growth, weld joint code and strain ageing). (author)

  12. Dissolution-Enlarged Fractures Imaging Using Electrical Resistivity Tomography (ERT)

    Science.gov (United States)

    Siami-Irdemoosa, Elnaz

    In recent years the electrical imaging techniques have been largely applied to geotechnical and environmental investigations. These techniques have proven to be the best geophysical methods for site investigations in karst terrain, particularly when the overburden soil is clay-dominated. Karst is terrain with a special landscape and distinctive hydrological system developed by dissolution of rocks, particularly carbonate rocks such as limestone and dolomite, made by enlarging fractures into underground conduits that can enlarge into caverns, and in some cases collapse to form sinkholes. Bedding planes, joints, and faults are the principal structural guides for underground flow and dissolution in almost all karstified rocks. Despite the important role of fractures in karst development, the geometry of dissolution-enlarged fractures remain poorly unknown. These features are characterized by an strong contrast with the surrounding formations in terms of physical properties, such as electrical resistivity. Electrical resistivity tomography (ERT) was used as the primary geophysical tool to image the subsurface in a karst terrain in Greene County, Missouri. Pattern, orientation and density of the joint sets were interpreted from ERT data in the investigation site. The Multi-channel Analysis of Surface Wave (MASW) method and coring were employed to validate the interpretation results. Two sets of orthogonal visually prominent joints have been identified in the investigation site: north-south trending joint sets and west-east trending joint sets. However, most of the visually prominent joint sets are associated with either cultural features that concentrate runoff, natural surface drainage features or natural surface drainage.

  13. Morphological Changes Of The Root Surface And Fracture Resistance After Treatment Of Root Fracture By CO2 Laser And Glass Ionomer Or Mineral Trioxide Aggregates

    Science.gov (United States)

    Badr, Y. A.; Abd El-Gawad, L. M.; Ghaith, M. E.

    2009-09-01

    This in vitro study evaluates the morphological changes of the root surface and fracture resistance after treatment of root cracks by CO2 laser and glass Ionomer or mineral trioxide aggregates (MTA). Fifty freshly extracted human maxillary central incisor teeth with similar dimension were selected. Crowns were sectioned at the cemento-enamel junction, and the lengths of the roots were adjusted to 13 mm. A longitudinal groove with a dimension of 1×5 mm2 and a depth of 1.5 mm was prepared by a high speed fissure bur on the labial surface of the root. The roots were divided into 5 groups: the 10 root grooves in group 1 were remained unfilled and were used as a control group. The 10 root grooves in group 2 were filled with glass Ionomer, 10 root grooves in group 3 were filled with MTA, the 10 root grooves in group 4 were filled with glass Ionomer and irradiated by CO2 laser and the 10 root grooves in group 5 were filled with MTA and irradiated with CO2 laser. Scanning electron microscopy was performed for two samples in each group. Tests for fracture strength were performed using a universal testing machine and a round tip of a diameter of 4 mm. The force was applied vertically with a constant speed of 1 mm min 1. For each root, the force at the time of fracture was recorded in Newtons. Results were evaluated statistically with ANOVA and Turkey's Honestly Significant Difference (HSD) tests. SEM micrographs revealed that the melted masses and the plate-like crystals formed a tight Chemical bond between the cementum and glass Ionomer and melted masses and globular like structure between cementum and MTA. The mean fracture resistance was the maximum fracture resistance in group 5 (810.8 N). Glass Ionomer and MTA with the help of CO2 laser can be an alternative to the treatment of tooth crack or fracture. CO2 laser increase the resistance of the teeth to fracture.

  14. J-R Fracture Resistance of SA533 Gr.B-Cl.1 Steel for Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ji-Hyun; Hong, Seokmin; Lee, Bong-Sang [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    A rolled plate might show different mechanical behaviors from a forging, even though they contain same chemical compositions. Furthermore, it is known that the fracture behavior of a rolled plate is very sensitive to material orientation comparing to a forging. In this study, the J-R fracture resistances of SA533 Gr.B-Cl.1 plate were measured at reactor operating temperature and the material orientation sensitivity was discussed. The decrease of fracture resistance of this kind of low alloy steel at an elevated temperature is known as the effect of dynamic strain aging (DSA). It was attributed to that the carbides and grains elongated to primary rolling direction, so that the aspect ratio of carbides and grains in the specimen with T-L orientation is larger. Generally, the hard second phase could take a roll of trigger point of unstable fracture. It is needed that the fracture surfaces of the tested specimens to be examined profoundly.

  15. Short-term effect of zoledronic acid upon fracture resistance of the mandibular condyle and femoral head in an animal model.

    Science.gov (United States)

    Camacho-Alonso, Fabio; López-Jornet, Pía; Vicente-Hernández, Ascensión

    2013-05-01

    The aim of this study was to compare the effects in terms of resistance to fracture of the mandibular condyle and femoral head following different doses of zoledronic acid in an animal model. A total of 80 adult male Sprague-Dawley rats were included in a prospective randomized study. The animals were randomly divided into four groups of 20 rats each. Group 1 (control) received sterile saline solution, while groups 2, 3 and 4 received a accumulated dose of 0.2 mg, 0.4 mg and 0.6 mg of zoledronic acid, respectively. The animals were sacrificed 28 days after the last dose, and the right hemimandible and the right femur were removed. The fracture strength was measured (in Newtons) with a universal test machine using a 1 kN load connected to a metal rod with one end angled at 30 degrees. The cross-head speed was 1 mm/min. Later, the specimens were observed under a scanning electron microscope with backscattered electron imaging (SEM-BSE). At last, chemical analysis and elemental mapping of the mineral bone composition were generated using a microanalytical system based on energy-dispersive and X-ray spectrometry (EDX). A total of 160 fracture tests were performed. The fracture resistance increased in mandible and femur with a higher accumulated dose of zoledronic acid. Statistically significant differences were recorded versus the controls with all the studies groups. The chemical analysis in mandible showed a significantly increased of calcium and phosphorous to compare the control with all of the study groups; however, in femur no statistically significant differences between the four study groups were observed. The administration of bisphosphonates increases the fracture resistance in mandible and femur.

  16. Impact resistance and interlaminar fracture toughness of through-the-thickness reinforced graphite/epoxy

    Science.gov (United States)

    Dexter, H. B.; Funk, J. G.

    1986-01-01

    Five through-the-thickness stitch configurations are analyzed to determine the effect of impact resistance and interlaminar fracture toughness on T3000/3501-6 graphite/epoxy. The test specimens were stitched with either polyester or Kevlar yarns and with various stitch parameters. Tension and compression mechanical, impact and compression-after-impact, and double cantilever beam tests were conducted. It is observed that the stitched laminates have tension and compression strengths 20-25 percent lower than the strengths of unstitched laminates, the tension strength of stitched laminates is reduced with increasing number of stitches, and the compression strength increases as the number of stitches are increased. The impact data reveal that the Kevlar stitched laminates have less damage than unstitched laminates; the most effective configuration for suppressing impact damage and improving interlaminar fracture toughness consists of Kevlar yarns 1/4 inch apart with eight stitches per inch. The mode 1 critical strain energy release rate for the 1/4 inch Kevlar eight stitch laminate was calculated as 30 times higher than that of the unstitched.

  17. The application of DCPD method to evaluating dynamic J-R fracture resistance characteristics

    International Nuclear Information System (INIS)

    Yoon, Ji Hyun; Hong, Jun Hwa; Lee, Bong Sang; Chi, Se Whan; Kim, Joo Hag; Oh, Yong Jun; Kwun, Sun Chil; Oh, Jong Myung

    1999-06-01

    The reliable DCPD (Direct Current Potential Drop) test and data acquisition system were developed on the basis of analysis of various technical problems to accompanied with the application of DCPD method to J-R fracture resistance test. The test system contains electric insulation rod and high performance data acquisition system. The test and analysis method was applied to J-R fracture resistance test for SA516-Gr.70 steel for nuclear primary coolant system elbow. The reliabilities of test and analysis method were confirmed through the load-ratio method in case of dynamic loading test, and through the standard unloading compliance test in case of static loading test. (author). 17 refs., 1 tab., 18 figs

  18. The application of DCPD method to evaluating dynamic J-R fracture resistance characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ji Hyun; Hong, Jun Hwa; Lee, Bong Sang; Chi, Se Whan; Kim, Joo Hag; Oh, Yong Jun; Kwun, Sun Chil; Oh, Jong Myung

    1999-06-01

    The reliable DCPD (Direct Current Potential Drop) test and data acquisition system were developed on the basis of analysis of various technical problems to accompanied with the application of DCPD method to J-R fracture resistance test. The test system contains electric insulation rod and high performance data acquisition system. The test and analysis method was applied to J-R fracture resistance test for SA516-Gr.70 steel for nuclear primary coolant system elbow. The reliabilities of test and analysis method were confirmed through the load-ratio method in case of dynamic loading test,and through the standard unloading compliance test in case of static loading test. (author). 17 refs., 1 tab., 18 figs.

  19. Biomechanical study: resistance comparison of posterior antiglide plate and lateral plate on synthetic bone models simulating Danis-Weber B malleolar fractures

    Directory of Open Access Journals (Sweden)

    Bruna Buscharino

    2013-06-01

    Full Text Available OBJECTIVE : The purpose of this study was to compare different positions of plates in lateral malleolar Danis-Weber B fractures on synthetic bone: a lateral plate and a posterior antiglide plate. METHODS : Short oblique fractures of distal fibula at the level of the syndesmosys were simulated with a fibular osteotomy in sixteen synthetic fibula bones (Synbone®. Eight fractures were fixed with lateral plating associated with an independent lag screw, and the other eight were fixed with posterior antiglide plating with a lag screw through the plate. A strain gage was installed at the center of each plate at the osteotomy site. Supination and external rotation forces were applied to each of the two groups at the bend. RESULTS : The lateral position plate group suffered more deformity in response to supination forces compared to the group with the posterior antiglide plate, but this result was not statistically significant. In the tests with external rotation forces, the posterior antiglide plating group had significantly higher resistance (p < 0.05. CONCLUSION : When subjected to external rotation forces, osteosynthesis with posterior antiglide plate models simulating type B fractures of the lateral malleolus of the ankle is more resistant than that of the neutralization plate.

  20. Effect of Crack Tip Stress Concentration Factor on Fracture Resistance in Vacuum Environment

    Science.gov (United States)

    2015-01-20

    indicate: (1) in all alloys, the fracture resistance is highest for blunt-notches (smaller Kt), and is lowest for fatigue -sharpened precracked...paths are transgranular and the fracture mode is ductile void coalescence in all cases, irrespective of the stress concentration factor. 20-01-2015...because of corrosion and/or various loading conditions such as fatigue , fretting, abrasion, etc. Also, the geometry of the structure may cause an

  1. In vitro fracture resistance of endodontically treated central incisors with varying ferrule heights and configurations.

    Science.gov (United States)

    Tan, Philip L B; Aquilino, Steven A; Gratton, David G; Stanford, Clark M; Tan, Swee Chian; Johnson, William T; Dawson, Deborah

    2005-04-01

    The in vitro effectiveness of a uniform circumferential ferrule has been established in the literature; however, the effect of a nonuniform circumferential ferrule height on fracture resistance is unknown. This in vitro study investigated the resistance to static loading of endodontically treated teeth with uniform and nonuniform ferrule configurations. Fifty extracted intact maxillary human central incisors were randomly assigned to 1 of 5 groups: CRN, no root canal treatment (RCT), restored with a crown; RCT/CRN, no dowel/core, restored with a crown; 2 FRL, 2-mm ferrule, cast dowel/core and crown; 0.5/2 FRL, nonuniform ferrule (2 mm buccal and lingual, 0.5 mm proximal), cast dowel/core and crown; and 0 FRL, no ferrule, cast dowel/core and crown. The teeth were prepared to standardized specifications and stored for 72 hours in 100% humidity prior to testing. Testing was conducted with a universal testing machine with the application of a static load, and the load (N) at failure was recorded. Statistical analysis was performed with a 1-way analysis of variance and the Tukey Honestly Significant Difference test (alpha=.05). The mode of fracture was noted by visual inspection for all specimens. There was strong evidence of group differences in mean fracture strength ( P <.0001). Following adjustment for all pairwise group comparisons, it was found that the lack of a ferrule resulted in a significantly lower mean fracture strength (0 FRL: 264.93 +/- 78.33 N) relative to all other groups. The presence of a nonuniform (0.5 to 2-mm vertical height) ferrule (0.5/2 FRL: 426.64 +/- 88.33 N) resulted in a significant decrease ( P =.0001) in mean fracture strength when compared with the uniform 2-mm vertical ferrule (2 FRL: 587.23 +/- 110.25 N), the group without RCT (CRN: 583.67 +/- 86.09 N), and the RCT-treated tooth with a crown alone (CRN/RCT: 571.04 +/- 154.86 N). The predominant mode of failure was an oblique fracture extending from the lingual margin to the facial

  2. Fracture resistance improvement of polypropylene by joint action of core-shell particles and nucleating agent

    International Nuclear Information System (INIS)

    Yang Gang; Han Liang; Ding Haifeng; Wu Haiyan; Huang Ting; Li Xiaoxi; Wang Yong

    2011-01-01

    Research highlights: →The core-shell particles, which were prepared from melt blending of POE and nano-CaCO 3 , and different nucleating agents (α-form NA or β-form NA) were first introduced into PP to prepare the super toughened PP materials. →NAs control the crystalline structures of PP matrix including the spherulites diameter and the crystal form. →NAs and core-shell particles exhibit apparent joint effect in improving the fracture resistance of PP. - Abstract: As a serial work about the fracture resistance improvement of polypropylene (PP), this work reports the joint effect of core-shell particles and nucleating agent (NA) on the microstructure and fracture resistance of PP. Core-shell particles were prepared through melt blending of ethylene-octene copolymer (POE) and calcium carbonate (CaCO 3 ). Different NA, i.e. α-form NA (P-tert-butylbenzoic acid-Al, MD-NA-28) and β-form NA (aryl amides compound, TMB-5) were introduced into PP matrix to control the crystalline structure. The phase morphology of POE and the distribution of CaCO 3 were characterized by using scanning electron microscope (SEM), and the crystallization behavior of PP matrix were investigated by using differential scanning calorimetry (DSC), wide angle X-ray diffraction (WAXD) and polarization optical microscope (POM). The mechanical properties were obtained through universal tensile measurement and notched Izod impact measurement. Surprisingly, the results show that through addition of so-called core-shell particles and NA simultaneously, the fracture resistance of PP can be dramatically improved.

  3. Effect of the ferrule on fracture resistance of teeth restored with ...

    African Journals Online (AJOL)

    However few studies have considered the effect of different ferrule designs on prefabricated post and composite core systems. Aim: This study investigated the effect of different ferrule designs on the fracture resistance of teeth incorporating prefabricated posts and composite cores. It also assessed the necessity of a post in ...

  4. Comparative evaluation of the vertical fracture resistance of endodontically treated roots filled with Gutta-percha and Resilon: a meta-analysis of in vitro studies.

    Science.gov (United States)

    Tan, Minmin; Chai, Zhaowu; Sun, Chengjun; Hu, Bo; Gao, Xiang; Chen, Yunjia; Song, Jinlin

    2018-06-13

    Teeth treated endodontically are more susceptible to vertical root fracture (VRF). Some studies have suggested that obturating the root canals with Gutta-percha or Resilon can reinforce endodontically treated teeth, but a few others have presented conflicting results. These inconsistent results cannot guide clinicians in determining clinical approaches. The objective of this meta-analysis is to evaluate and compare the vertical fracture resistance of endodontically treated root canals obturated with Gutta-percha/AH plus and the Resilon system. Comprehensive literature searches were performed in the PubMed, Cochrane Library, ScienceDirect, Web of Science and Embase databases. The titles and abstracts of all of the retrieved articles were independently assessed by two authors according to predefined selection criteria. Data in the included articles were independently extracted. Statistical analyses were conducted using Review Manager 5.3 and Stata 12.0 software. The pooled standardized mean differences (SMDs) with 95% confidence intervals (CIs) were calculated for the outcome indicators. The level of statistical significance was set at p < 0.05. The Cochran Q test (I 2 test) was used to test for heterogeneity among studies. Fourteen randomized controlled in vitro trials were included in the meta-analysis. The results demonstrated that the vertical root fracture resistance of unprepared and unfilled roots was significantly higher than that of roots obturated with Gutta-percha/AH plus (SMD = - 0.69, 95% CI = - 1.34 to - 0.04, p = 0.04) or the Resilon system (SMD = - 0.54, 95% CI = - 1.07 to - 0.00, p = 0.05). The differences in fracture resistance between the roots filled with Gutta-percha/AH plus and the prepared unfilled root canals was not significant (SMD = 0.59, 95% CI = - 0.02 to 1.21, p = 0.06). Roots obturated with Resilon had higher fracture resistance than instrumented unfilled roots (SMD = 0.83, 95

  5. Fracture mechanical investigations about crack resistance behaviour in non-transforming ceramics in particular aluminum oxide

    International Nuclear Information System (INIS)

    Baer, K.K.O.; Kleist, G.; Nickel, H.

    1991-03-01

    The aim of this work is the clearification of R-curve behaviour of non-transforming ceramics, in particular aluminum oxide exhibiting incrystalline fracture. Investigations of crack growth in controlled bending experiments were performed using 3-Pt- and 4-Pt-bending samples of differing sizes under inert conditions. The fracture experiments were realized using several loading techniques, for example constant and varying displacement rates, load rupture (P = 0) and relaxation tests (v = 0). In addition unloading and reloading experiments were performed to investigate hysteresis curves and residual displacements in accordance with R-curve behaviour. During the crack-growth experiments, the crack extension was measured in situ using a high resolution immersion microscope. With this technique, the fracture processes near the crack tip (crack activity zone) was observed as well. The crack resistance as a function of crack extension (R-curve) was determined using differing calculation methods. All of the methods used resulted in approximately identical R-curves, within the statistical error band. The crack resistance at initiation R 0 was 20 N/m. The crack resistance increased during approximately 3 mm of growth to a maximum of 90 N/m. A decrease in the crack resistance was determined for large a/W (crack length normalized with sample height) values, independant of the calculation methods. The R-curve behaviour was interpreted as due to a functional resistance behind the observed crack tip, which arises from a volume dilatation in the crack activity zone while the crack proceeds. (orig.) [de

  6. Marginal ridge fracture resistance, microleakage and pulpal response to glass ionomer/glass cermet partial tunnel restorations.

    Science.gov (United States)

    Prabhu, N T; Munshi, A K; Shetty, T R

    1997-01-01

    Sixty sound premolars which were to be extracted for orthodontic treatment purposes were restored either with glass ionomer cement or glass cermet cements after partial tunnel preparation, and prior to the extraction after a time interval of 30 and 60 days respectively. The teeth were then subjected to marginal ridge fracture resistance, microleakage study using dye penetration and histological evaluation of the pulpal response to these materials. Both the materials exhibited increase in marginal ridge fracture resistance at 60 days, with minimal degree of microleakage and were biologically compatible with the dental pulp.

  7. Using DC electrical resistivity tomography to quantify preferential flow in fractured rock environments

    CSIR Research Space (South Africa)

    May, F

    2011-09-01

    Full Text Available . This investigation aims to identify preferential flow paths in fractured rock environments. Time-lapse Electrical Resistivity Tomography (TLERT, Lund Imaging System), is regarded as a suitable method for identifying preferential water flow....

  8. The relationship between diameter and taper of nickel-titanium rotary instruments on the torsional resistance to fracture

    Directory of Open Access Journals (Sweden)

    Erick Miranda Souza

    Full Text Available Objective: To evaluate the resistance to fracture of rotary Ni-Ti files of various diameters and tapers after torsional stress simulation. Methods: Profile (Dentsply Maillerfer, Ballaigues, Suíça instruments sizes 15 to 40, taper 0.04 and 0.06 were used. Ten instruments of each size and taper were tested, totaling 120 files. The maximum torque (Tmax until fracture was determined in accordance with the ANSI / ADA Protocol Nº 28 . The maximum force was converted into maximum torque using the formula: Tmax = Loadmax x RadiusResults: The diameter (p<0.001 and taper (p<0.001 influenced the maximum torque to fracture. With the increase in diameter and taperthere was a gradual increase in the maximum torque. Using the multiple regression method an equation relating the maximum torque to the diameter (D and the taper (T was found: Tmax = -1.4 + 0.08D + 10.5T. Conclusion: The increase in diameter and taper promoted an increase in resistance to torsion. The variation of the taper from 0.04 to 0.06 in instruments with the same diameter increased resistance to fracture by torsion by around 25%.

  9. Role of Alcohol on the Fracture Resistance of Dentin

    Energy Technology Data Exchange (ETDEWEB)

    Nalla, Ravi K.; Kinney, John H.; Tomsia, Antoni P.; Ritchie,Robert O.

    2006-05-01

    Healthy dentin, the mineralized tissue that makes up the bulk of the tooth, is naturally hydrated in vivo; however, it is known that various chemical reagents including acetone and ethanol can induce dehydration and thereby affect its properties. Here, we seek to investigate this in light of the effect alcohol can have on the mechanical properties of dentin, specifically by measuring the stiffness, strength and toughness of dentin in simulated body fluid and scotch whisky. Results indicate that chemical dehydration induced by the whisky has a significant beneficial effect on the elastic modulus, strength and fracture toughness of dentin. Although this makes teeth more resistant to fracture, the change in properties is fully reversible upon rehydration. This effect is considered to be associated with increased cross-linking of the collagen molecules from intermolecular hydrogen-bonding where water is replaced with weaker hydrogen-bond forming solvents such as alcohol.

  10. Fracture mechanics behaviour of neutron irradiated Alloy A-286

    International Nuclear Information System (INIS)

    Mills, W.J.; James, L.A.

    The effect of fast-neutron irradiation on the fatigue-crack propagation and fracture toughness behaviour of Alloy A-286 was characterized using fracture mechanics techniques. The fracture toughness was found to decrease continuously with increasing irradiation damage at both 24 deg. C and 427 deg. C. In the unirradiated and low fluence conditions, specimens displayed appreciable plasticity prior to fracture, and equivalent Ksub(Ic) values were determined from Jsub(Ic) fracture toughness results. At high irradiation exposure levels, specimens exhibited a brittle Ksub(Ic) fracture mode. The 427 deg. C fracture toughness fell from 129 MPa√m in the unirradiated condition to 35 MPa√m at an exposure of 16.2 dpa (total fluence of 5.2x10 22 n/cm 2 ). Room temperature fracture toughness values were consistently 40 to 60 percent higher than the 427 deg. C values. Electron fractography revealed that the reduction in fracture resistance was attributed to a fracture mechanism transition from ductile microvoid coalescence to channel fracture. Fatigue-crack propagation tests were conducted at 427 deg. C on specimens irradiated at 2.4 dpa and 16.2 dpa. Crack growth rates at the lower exposure level were comparable to those in unirradiated material, while those at the higher exposure were slightly higher than in unirradiated material. (author)

  11. Evaluation of fatigue crack growth and fracture resistance of SA350 LF2 material

    International Nuclear Information System (INIS)

    Singh, P.K.; Dubey, J.S.; Chakrabarty, J.K.; Vaze, K.K.; Kushwaha, H.S.

    2003-01-01

    The aim of the present paper is to evaluate the tensile and fracture mechanics properties of the SA350 LF2 carbon steel material used as the Header material in the primary heat transport (PHT) system piping of the Indian pressurized heavy water reactors (PHWR). Tensile, fatigue crack growth rate and fracture toughness tests have been carried out on specimens machined from the Header of the actual PHT pipes. The effect of temperature on tensile properties has been discussed. The effect of temperature and notch orientation on fracture resistance behavior of the material and fatigue crack growth rate dependence on the notch orientation and stress ratio has also been discussed. (author)

  12. Fracture resistance of weakened teeth restored with condensable resin with and without cusp coverage

    Directory of Open Access Journals (Sweden)

    Rafael Francisco Lia Mondelli

    2009-06-01

    Full Text Available OBJECTIVES: This in vitro study evaluated the fracture resistance of weakened human premolars (MOD cavity preparation and pulp chamber roof removal restored with condensable resin composite with and without cusp coverage. MATERIAL AND METHODS: Thirty human maxillary premolars were divided into three groups: Group A (control, sound teeth; Group B, wide MOD cavities prepared and the pulp chamber roof removed and restored with resin composite without cusp coverage; Group C, same as Group B with 2.0 mm of buccal and palatal cusps reduced and restored with the same resin. The teeth were included in metal rings with self-curing acrylic resin, stored in water for 24 h and thereafter subjected to a compressive axial load in a universal testing machine at 0.5 mm/min. RESULTS: The mean fracture resistance values ± standart deviation (kgf were: group A: 151.40 ± 55.32, group B: 60.54 ± 12.61, group C: 141.90 ± 30.82. Statistically significant differences were found only between Group B and the other groups (p<0.05. The condensable resin restoration of weakened human premolars with cusp coverage significantly increased the fracture resistance of the teeth as compared to teeth restored without cusp coverage. CONCLUSION: The results showed that cusp coverage with condensable resin might be a safe option for restoring weakened endodontically treated teeth.

  13. In vitro compressive fracture resistance of human maxillary first premolar with different mesial occlusal distal cavity

    Directory of Open Access Journals (Sweden)

    Wen-Chou Wu

    2014-09-01

    Conclusion: A bonded ceramic restoration restores the fracture load of a tooth comparable to an intact tooth independent of the examined design parameters, whereas the fracture loads of composite-resin-restored teeth were dependent on cavity widths. Cavity pulpal floor depth is not a significant factor of cusp fracture resistance in a tooth restored with either a ceramic inlay or composite resin.

  14. All-Ceramic Single Crown Restauration of Zirconia Oral Implants and Its Influence on Fracture Resistance: An Investigation in the Artificial Mouth

    Directory of Open Access Journals (Sweden)

    Ralf-Joachim Kohal

    2015-04-01

    Full Text Available The aim of the current investigation was to evaluate the fracture resistance of one-piece zirconia oral implants with and without all-ceramic incisor crowns after long-term thermomechanical cycling. A total of 48 implants were evaluated. The groups with crowns (C, 24 samples and without crowns (N, 24 samples were subdivided according to the loading protocol, resulting in three groups of 8 samples each: Group “0” was not exposed to cyclic loading, whereas groups “5” and “10” were loaded with 5 and 10 million chewing cycles, respectively. This resulted in 6 different groups: C0/N0, C5/N5 and C10/N10. Subsequently, all 48 implants were statically loaded to fracture and bending moments were calculated. All implants survived the artificial aging. For the static loading the following average bending moments were calculated: C0: 326 Ncm; C5: 339 Ncm; C10: 369 Ncm; N0: 339 Ncm; N5: 398 Ncm and N10: 355 Ncm. To a certain extent, thermomechanical cycling resulted in an increase of fracture resistance which did not prove to be statistically significant. Regarding its fracture resistance, the evaluated ceramic implant system made of Y-TZP seems to be able to resist physiological chewing forces long-term. Restauration with all-ceramic single crowns showed no negative influence on fracture resistance.

  15. Fracture resistance of bleached teeth restored with different procedures

    Directory of Open Access Journals (Sweden)

    Matheus Coelho Bandéca

    2012-08-01

    Full Text Available This study evaluated the fracture resistance of teeth submitted to internal bleaching and restored with different non-metallic post. Eighty mandibular incisors were endodontically treated and randomly divided in 10 groups (n = 8: G1- restored with composite resin (CR, G2- CR + fiber-reinforced composite post (FRC, Everstick post, Sticktech cemented with resin cement self-etch adhesive (RCS, Panavia F 2.0, Kuraray, G3- CR + FRC + self-adhesive resin cement (SRC, Breeze, Pentral Clinical, G4- CR+ glass fiber post (GF, Exacto Post, Angelus + RCS, G5- CR + GF + SRC. The G6 to G10 were bleached with hydrogen peroxide (HP and restored with the same restorative procedures used for G1 to G5, respectively. After 7 days storage in artificial saliva, the specimens were submitted to the compressive strength test (N at 0.5 mm/min cross-head speed and the failure pattern was identified as either reparable (failure showed until 2 mm below the cement-enamel junction or irreparable (the failure showed <2 mm or more below the cement-enamel. Data were analyzed by ANOVA and Tukey test (α = 0.05. No significant difference (p < 0.05 was found among G1 to G10. The results suggest that intracoronal bleaching did not significantly weaken the teeth and the failure patterns were predominately reparable for all groups. The non-metallic posts in these teeth did not improve fracture resistance.

  16. Comparison of Chamfer and Deep Chamfer Preparation Designs on the Fracture Resistance of Zirconia Core Restorations

    Directory of Open Access Journals (Sweden)

    Ezatollah Jalalian

    2011-06-01

    Full Text Available Background and aims. One of the major problems of all-ceramic restorations is their probable fracture under occlusal force. The aim of the present in vitro study was to compare the effect of two marginal designs (chamfer and deep chamfer on the fracture resistance of all-ceramic restorations, CERCON. Materials and methods. This in vitro study was carried out with single-blind experimental technique. One stainless steel die with 50’ chamfer finish line design (0.8 mm deep was prepared using a milling machine. Ten epoxy resin dies were prepared. The same die was retrieved and 50' chamfer was converted into a deep chamfer design (1 mm. Again ten epoxy resin dies were prepared from the deep chamfer die. Zirconia cores with 0.4 mm thickness and 35 µm cement space were fabricated on the epoxy resin dies (10 chamfer and 10 deep chamfer samples. The zirconia cores were cemented on the epoxy resin dies and underwent a fracture test with a universal testing machine and the samples were investigated from the point of view of the origin of the failure. Results. The mean values of fracture resistance for deep chamfer and chamfer samples were 1426.10±182.60 and 991.75±112.00 N, respectively. Student’s t-test revealed statistically significant differences between the groups. Conclusion. The results indicated a relationship between the marginal design of zirconia cores and their fracture resistance. A deep chamfer margin improved the biomechanical performance of posterior single zirconia crown restorations, which might be attributed to greater thickness and rounded internal angles in deep chamfer margins.

  17. Effect of reverse cyclic loading on the fracture resistance curve in C(T) specimen

    International Nuclear Information System (INIS)

    Sung Seok, C.; Jin Kim, Y.; Il Weon, J.

    1999-01-01

    Fracture resistance (J-R) curves, which are used for elastic-plastic fracture mechanics analyses, are known to be dependent on the cyclic loading history. The objective of this paper is to investigate the effect of reverse cyclic loading on the J-R curves in C(T) specimens. The effect of two parameters was observed on the J-R curves during the reverse cyclic loading. One was the minimum-to-maximum load ratio (R) and the other was the incremental plastic displacement (δ cycle /δ i ), which is related to the amount of crack growth that occurs in a cycle. Fracture resistance tests on C(T) specimens with varying the load ratio and the incremental plastic displacement were performed, and the test results showed that the J-R curves were decreased with decreasing the load ratio and decreasing the incremental plastic displacement. Direct current potential drop (DCPD) method was used for the detection of crack initiation and crack growth in typical laboratory J-R tests. The values of crack initiation J-integral (J I ) and crack initiation displacement (δ i ) were also obtained by using the DCPD method. (orig.)

  18. Evaluation of elastic-plastic fracture of toughness and fracture resistance of carbon steel STS42

    International Nuclear Information System (INIS)

    Kobayashi, Hideo; Nakamura, Haruo; Kashiwagi, Kohmei

    1987-01-01

    The elastic-plastic fracture toughness (J Ic ) and fracture resistance (J-R curve) of a carbon steel, STS42, used for piping in a nuclear reactor were evaluated according to the several evaluating methods recommended or proposed so far, to discuss their applicability and utility. The results obtained are as follows: (1) In evaluating J Ic , the multiple specimen method recommended by the Japan Society for Mechanical Engineers (JSME standard S001) gives the most reliable results by using smaller sized specimens. (2) The single-specimen methods by using the compliance technique, adopted in the ASTM standards (E813, E813 modified, Tentative test procedure for determining the plain strain J-R curve), do not give an accurate J-R curve or J Ic , due to an error in the calculated crack length. (3) In evaluating the J-R curve, it is necessary to account for crack extension in calculating the J-integral. (4) According to the above results, a new standard method for determining the J-R curve including the J Ic test method should be poprosed. (author)

  19. Evaluation of resistance of teeth subjected to fracture after endodontic treatment using different root canal sealers: An in vitro study

    Directory of Open Access Journals (Sweden)

    S S Bhat

    2012-01-01

    Full Text Available Aims: The aim of this study was to compare the ex-vivo effects of different root canal sealers on the fracture resistance of endodontically treated teeth. Materials and Methods: Seventy-five freshly extracted human mandibular premolars were used for the study. The length was standardized to 14 mm and all the teeth were biomechanically prepared and divided into five different groups based on the type of root canal sealers used. Group I:- Roeko seal + gutta percha, Group II: AH plus ® root canal sealer + gutta percha, Group III: PULPDENT root canal sealer + gutta percha, Group IV: Zinc oxide-eugenol sealer + gutta percha, Group V: Control (unobturated teeth. The teeth were embedded in acrylic resin blocks and compressive strengths were measured using universal testing machine (Instron. Statistical Analysis Used: One-way ANOVA, unpaired t- test Results: Data obtained were statistically evaluated using one-way ANOVA and unpaired t-test. All groups showed a statistically significant result (P < 0.05. Teeth obturated with Group I and Group II showed higher resistance to fracture than teeth obturated with other three Groups. It was seen that the teeth obturated with group III showed a better fracture resistance than Group IV and there was no statistical significance found between Group and Group V. Conclusions: From this study, it has been concluded that both the resin based sealers that were used in this study were equally effective compared to that of the zinc oxide-based sealers and the control group. However, no significant results were obtained when the comparison was made between zinc oxide-eugenol and gutta-percha and the control group.

  20. Resistance to fracture of endodontically treated premolars restored with glass ionomer cement or acid etch composite resin: An in vitro study

    Directory of Open Access Journals (Sweden)

    B Ranga

    2010-01-01

    Full Text Available Aim: Due to the weakness of endodontically treated posterior teeth requires more strengthened restoration to withstand occlusal forces. The purpose of the present study was to determine and compare the resistance to fracture of endodontically treated maxillary 1 st premolars restored with different materials in mesio-occluso-distal (MOD cavity preparations. Materials and Methods: MOD cavity preparations in 80 endodontically treated maxillary 1 st premolars were restored using four different methods. Fiber rings were filled with stone plaster and the teeth were placed into the plaster up to the level of cemento-enamel junction. The teeth were grouped according to restorative method, mounted in an Instrom T.T. machine, and the buccal walls subjected to a slowly increasing compressive force until fracture occurred. Result: The force of fracture of the walls of each tooth was recorded and the results in the various groups compared. All teeth fractured in a similar manner irrespective of the restorative method used. Conclusion: The resistance to the fracture of the teeth was the same when they were stored with glass ionomer cement as a base over which composite resin was placed. When the entire cavities were filled with glass ionomer cement, the resistance to fracture of the teeth decreased significantly compared with the acid etch resin technique.

  1. Serum vitamin E concentrations among highly functioning hip fracture patients are higher than in nonfracture controls.

    Science.gov (United States)

    D'Adamo, Christopher R; Shardell, Michelle D; Hicks, Gregory E; Orwig, Denise L; Hochberg, Marc C; Semba, Richard D; Yu-Yahiro, Janet A; Ferrucci, Luigi; Magaziner, Jay S; Miller, Ram R

    2011-03-01

    fracture patients demonstrated higher vitamin E concentrations. Thus, the relatively high degree of function among this cohort of hip fracture patients may explain their higher-than-expected vitamin E concentrations. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Impact fracture behavior of HT9 duct

    International Nuclear Information System (INIS)

    Huang, F.H.; Gelles, D.S.

    1994-07-01

    Ferritic alloys are known to undergo a ductile-brittle transition as the test temperature is decreased. This inherent problem has limited their applications to reactor component materials subjected to low neutron exposures. However, the excellent resistance to void swelling exhibited by these alloys has led to choosing the materials as candidate materials for fast and fusion reactor applications. Despite the ductile-brittle transition problem, results show that the materials exhibit superior resistance to fracture under very high neutron fluences at irradiation temperatures above 380 degrees C. Impact testing on FFTF duct sections of HT9 indicates that HT9 ducts have adequate fracture toughness at much higher temperatures for handling operations at room temperature and refueling operations

  3. Effects of progressive resistance training on physical disability among older community-dwelling people with history of hip fracture.

    Science.gov (United States)

    Edgren, Johanna; Rantanen, Taina; Heinonen, Ari; Portegijs, Erja; Alén, Markku; Kiviranta, Ilkka; Kallinen, Mauri; Sipilä, Sarianna

    2012-04-01

    Hip fracture is a common trauma in older people, and often leads to decreased muscle strength and increased physical disability. This randomized controlled trial examined whether three months of progressive resistance training (PRT) can reduce physical disability among older people with a history of hip fracture. A population-based sample of 60-85-year-old community- dwelling persons, with hip fractures sustained on average three years earlier, were enrolled in the study. Of 78 people participating in laboratory assessments, those without contraindications for participation in resistance training were randomly assigned to a training group (TG, n=22) or a control group (CG, n=21). TG took part in resistance training for three months twice a week. Training focused on lower limb muscles. Disability was assessed by a validated questionnaire containing six questions on activities of daily living (ADL) and nine on instrumental activities of daily living (IADL). A sum score was calculated separately for both items. High scores indicated more difficulties. Group differences were analysed with the Mann-Whitney and Chi-square tests. The effects of PRT on disability were tested with the McNemar test and by covariance analysis (ANCOVA). TG and CG were comparable with respect to gender, age, chronic diseases, BMI, time since fracture, self-reported health, and level of physical activity at baseline. The ADL sum score in TG was 1.8 (2.0) at baseline and 1.1 (1.3) after follow-up; in CG values were 1.7 (1.8) and 1.5 (1.8) (ANCOVA p=0.034). IADL sum scores in TG were 3.9 (4.6) at baseline and 2.2 (3.8) after follow-up, and in CG 3.4 (3.6) and 2.4 (2.3) (ANCOVA p=0.529). Progressive resistance training reduced self-reported difficulties in ADL, even several years after fracture. More research is still needed on how to prevent physical disability among community-dwelling older people, especially after hip fracture.

  4. Metallic Reinforcement of Direct Squeeze Die Casting Aluminum Alloys for Improved Strength and Fracture Resistance

    Energy Technology Data Exchange (ETDEWEB)

    D. Schwam: J.F. Wallace: Y. Zhu: J.W. Ki

    2004-10-01

    obtained with unreinforced 356 aluminum casting. Good strength can be obtained with a sound die casting without any defects produced by squeeze casting. The use of higher pressure to produce the squeeze casting has been shown to increase the strength of a hemispherical dome casting. This dome shape casting has been produced both with and without reinforcement and tested to determine its pressure resistance under internal pressure of water. Only a slight improvement in strength could be determined because of water leaks at the seal between hemispherical dome and its flat supporting side. However, when the ability of the casting was tested under the compressive force of a plunger, the strengthening effect of wire mesh or sheet was evident. Higher loads to failure were obtained because of the reinforcement of the stainless steel wire and punched sheet. Rather than a sudden failure occurring, the reinforcement of the stainless steel wire or the punched hard stainless steel sheet held the material together and prevented any loss of the fractured casting to the surroundings. Unalloyed steel did not have the required strength or mechanical properties to increase the properties of the casting.

  5. Topological design of all-ceramic dental bridges for enhancing fracture resistance.

    Science.gov (United States)

    Zhang, Zhongpu; Chen, Junning; Li, Eric; Li, Wei; Swain, Michael; Li, Qing

    2016-06-01

    Layered all-ceramic systems have been increasingly adopted in major dental prostheses. However, ceramics are inherently brittle, and they often subject to premature failure under high occlusion forces especially in the posterior region. This study aimed to develop mechanically sound novel topological designs for all-ceramic dental bridges by minimizing the fracture incidence under given loading conditions. A bi-directional evolutionary structural optimization (BESO) technique is implemented within the extended finite element method (XFEM) framework. Extended finite element method allows modeling crack initiation and propagation inside all-ceramic restoration systems. Following this, BESO searches the optimum distribution of two different ceramic materials, namely porcelain and zirconia, for minimizing fracture incidence. A performance index, as per a ratio of peak tensile stress to material strength, is used as a design objective. In this study, the novel XFEM based BESO topology optimization significantly improved structural strength by minimizing performance index for suppressing fracture incidence in the structures. As expected, the fracture resistance and factor of safety of fixed partial dentures structure increased upon redistributing zirconia and porcelain in the optimal topological configuration. Dental CAD/CAM systems and the emerging 3D printing technology were commercially available to facilitate implementation of such a computational design, exhibiting considerable potential for clinical application in the future. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  6. Characterization and quantification of preferential flow in fractured rock systems, using resistivity tomography

    CSIR Research Space (South Africa)

    May, F

    2010-11-01

    Full Text Available , N Jovanovic2 and A Rozanov1 University of Stellenbosch1 and Council for Scientific and Industrial Research (CSIR)2 Characterization and quantification of preferential flow in fractured rock systems, using resistivity tomography Introduction... of slow and fast flowing pathways. Materials and Methods TABLE 1 DATE, TIME AND WEATHER CONDITIONS DURING RESISTIVITY TOMOGRAPHY SURVEY Survey No. Date Start time End time Precipitation (mm) Description KB001 8/27/2010 12H00 13H40 0.0 Sunny KB002 8...

  7. [Comparative study of the fracture resistance of sound upper premolars and upper premolars restored with bonded amalgam].

    Science.gov (United States)

    Minto, André Marcelo Peruchi; Dinelli, Welingtom; Nonaka, Tomio; Thome, Luis Henrique de Camargo

    2002-01-01

    The purpose of this in vitro study was to determine the fracture resistance of upper premolars which had received class II preparations (conservative and extensive) and were restored with bonded amalgam, with two different adhesive systems. Seventy teeth were divided in four groups: group 1 (control), with ten sound teeth; group 2, with twenty prepared teeth (10 teeth received conservative cavities and 10, extensive cavities) restored with amalgam without any kind of liner; groups 3 and 4, similar to group 2, though with linings of glass ionomer cement (Vitrebond - 3M) (group 3) and dental adhesive (Scotchbond Multi-Purpose Plus - 3M) (group 4). The teeth were previously fixed in PVC cylinders with acrylic resin. After being restored and thermocycled, the test specimens were submitted to fracture by means of compression in an EMIC-MEM 2000 universal testing machine. After the application of the analysis of variance and complementary Tukey's test, we concluded that the utilized adhesive systems produced an increase of the fracture resistance of teeth presenting with conventional cavities; the teeth presenting with conservative cavities were more resistant in all experimental situations.

  8. Study of the fracture behavior of mortar and concretes with crushed rock or pebble aggregates

    Directory of Open Access Journals (Sweden)

    Sebastião Ribeiro

    2011-03-01

    Full Text Available The objective of this work was to compare the fracture energy of mortar and concretes produced with crushed rock and pebble aggregates using zero, 10, 20, 30 and 40% of aggregates mixed with standard mortar and applying the wedge splitting method to achieve stable crack propagation. The samples were cast in a special mold and cured for 28 days, after which they were subjected to crack propagation tests by the wedge splitting method to determine the fracture energies of the mortar and concrete. The concretes showed higher fracture energy than the mortar, and the concretes containing crushed rock showed higher resistance to crack propagation than all the compositions containing pebbles. The fracture energy varied from 38 to 55 J.m-2. A comparison of the number of aggregates that separated from the two concrete matrices with the highest fracture energies indicated that the concrete containing pebbles crumbled more easily and was therefore less resistant to crack propagation.

  9. Effect of reverse cyclic loading on the fracture resistance curve of nuclear piping material

    International Nuclear Information System (INIS)

    Weon, Jong Il; Seok, Chang Sung

    1999-01-01

    Fracture resistance (J-R) curves, which are used for the elastic-plastic fracture mechanics analyses, are known to be dependent on the cyclic loading history. The objective of this paper is to study the effect of reverse cyclic loading on J-R curves in CT specimens. The effect of two parameters was observed on the J-R curves during the reverse cyclic loading. One was the minimum-to-maximum load ratio (R) and the other was the incremental plastic displacement (δ cycle /δ i ), which is related to the amount of crack growth that occurs in a cycle. Fracture resistance test on CT specimens with varying load ratio and incremental plastic displacement were performed. For the SA 516 Gr. 70 steel, the results showed that the J-R curves were decreased with decreasing the load ratio and the incremental plastic displacement. When the load ratio was set to -1, the results of the J-R curves and the J i value were about 40-50 percent of those for the monotonic loading condition. Also on condition that the incremental plastic displacement reached 1/40, the J-R curves and the J i value were about 50-60 percent of those for the incremental plastic displacement of 1/10

  10. High-temperature fracture and fatigue resistance of a ductile β-TiNb reinforced γ-TiAl intermetallic composite

    International Nuclear Information System (INIS)

    Rao, K.T.V.; Ritchie, R.O.

    1998-01-01

    The high-temperature fatigue-crack propagation and fracture resistance of a model γ-TiAl intermetallic composite reinforced with 20 vol. % ductile β-TiNb particles is examined at elevated temperatures of 650 and 800 C and compared with behavior at room temperature. TiNb reinforcements are found to enhance the fracture toughness of γ-TiAl, even at high temperatures, from about 123 to ∼40 MPa m 1/2 , although their effectiveness is lower compared to room temperature due to the reduction in strength of TiNb particles. Under monotonic loading, crack-growth response in the composite is characterized by resistance-curve behavior arising from crack trapping, renucleation and resultant crack bridging effects attributable to the presence of TiNb particles. In addition, crack-tip blunting associated with plasticity increases the crack-initiation (matrix) toughness of the composite, particularly at 800 C, above the ductile-to-brittle transition temperature (DBTT) for γ-TiAl. High-temperature fatigue-crack growth resistance, however, is marginally degraded by the addition of TiNb particles in the C-R (edge) orientation, similar to observations made at room temperature; premature fatigue failure of TiNb ligaments in the crack wake diminishes the role of bridging under cyclic loading. Both fatigue and fracture resistance of the composite are slightly lower at 650 C (just below the DBTT for TiAl) compared to the behavior at ambient and 800 C. Overall, the beneficial effect of adding ductile TiNb reinforcements to enhance the room-temperature fracture and fatigue resistance of γ-TiAl alloys is retained up to 800 C, in air environments. There is concern, however, regarding the long-term environmental stability of these composite microstructures in unprotected atmospheres

  11. In vitro resistance to fracture of two nickel-titanium rotary instruments made with different thermal treatments.

    Science.gov (United States)

    Miccoli, Gabriele; Gaimari, Gianfranco; Seracchiani, Marco; Morese, Antonio; Khrenova, Tatyana; Di Nardo, Dario

    2017-01-01

    Aim of the study was to evaluate effectiveness of different heat treatments in improving Ni-Ti endodontic rotary instruments' resistance to fracture. 24 new NiTi instruments similar in length and shape: 12 M3 instruments, tip size 25 and .06 taper (United Dental, Shanghai, China), and 12 M3 Pro Gold instruments tip size 25 and .06 taper (United Dental, Shanghai, China), were tested in a 60° curved artificial root canal. Each group received a different heat treatment. Cycles to fracture were calculated for each instrument. Differences among groups were evaluated with an analysis of variance test (significance level was set at Pinstruments were significantly more resistant to fatigue (mean values = 1012, SD +/- 77) than M3 instruments (mean values = 748, SD +/- 62). No statistically significant differences were found between fragments' lengths (p>0,05). An increased flexibility and the reduction of internal defects produced by heat treatments during or after manufacturing processes, may be responsible for improving resistance to cyclic fatigue and flexural stresses.

  12. Fracture-tough, corrosion-resistant bearing steels

    Science.gov (United States)

    Olson, Gregory B.

    1990-01-01

    cryogenic forming, thus removing the high martensitic constraint, may permit alloy compositions offering higher fracture roughness.

  13. An in vitro study to determine fracture resistance of tooth roots after different instrumentation techniques

    Directory of Open Access Journals (Sweden)

    Marri Shilpa Reddy

    2016-01-01

    Conclusion: Preparation of canals with a conventional hand instrumentation technique using 0.02 taper K-files showed highest fracture resistance with least amount of dentin removed at all levels followed by Endowave, ProTaper Hand, and Rotary files.

  14. Effects of the Ratio between Pigment and Bleaching Gel on the Fracture Resistance and Dentin Microhardness of endodontically treated Teeth.

    Science.gov (United States)

    Galloza, Marina Og; Jordão-Basso, Keren Cf; Bandeca, Matheus C; Costa, Samuel O; Borges, Alvaro H; Tonetto, Mateus R; Tirintan, Fabio C; Keine, Kátia C; Kuga, Milton C

    2017-11-01

    The aim of this study was to evaluate the effects of bleaching gel using 35% hydrogen peroxide (HP), associated with red carmine pigment (RC), in the 3:1 or 1:1 ratio, on fracture resistance and dentin microhardness of endodontically treated teeth. A total of 40 lower incisors were endodontically treated and divided into four groups (n = 10), according to the bleaching protocol: G1 (HP3), 35% HP + RC (3:1); G2 (HP1), 35% HP + RC (1:1); G3 (positive), 38% HP; and G4 (negative), unbleached. Four dental bleaching sessions were performed. The dental crowns were restored after the last session and submitted to the fracture resistance test. Totally, 60 specimens from the endodontically treated lower incisor crowns were prepared to evaluate the effects on dentin microhardness. The analysis was measured (in Knoop) prior to and after the last dental bleaching session using similar bleaching protocols. G2 presented the lowest fracture resistance (p 0.05). No difference was observed in the reduction of dentin microhardness among the groups (p > 0.05). A 1:1 ratio (bleaching gel:pigment) caused a significant fracture resistance reduction in relation to the other protocols. No effect on the dentin microhardness reduction was observed. The pigment addition to the bleaching agent accelerates the bleaching chemical reaction. However, no studies have evaluated the ideal proportion to optimize tooth bleaching.

  15. A comparison between the effect of zirconia-coated FRC and glass fiber posts on the fracture resistance of endodontically treated teeth

    Directory of Open Access Journals (Sweden)

    Ezatollah Jalalian

    2014-04-01

    Full Text Available   Background and Aims : The root fracture resistance of endodontically treated teeth depends on the types of posts. The aim of this study was to compare the effect of two types of bonded non-metallic posts with different elasticity modulus on the fracture resistance of endodontically treated teeth under compressive loads.   Materials and Methods: In this in vitro experimental study, 20 fresh extracted mandibular premolars were selected and sectioned adjacent to the CEJ and then were endodontically treated. The specimens were randomly divided into two groups (n=10. After post space preparations, the fiber RTD Light posts (R.T.D, France and zirconia coated fiber posts (ICE light, Danville were cemented into the root canals. Composite resin (Lumiglass R.T.D, France cores were built up. Aluminium foil was used to mimic the PDL, and the specimens were embedded in acrylic resin and tested in a Universal Testing Machine. A compressive load was applied at a 90 degree angle until fracture at a crosshead speed of 1mm/min. Data were analyzed using one-way ANOVA and T test .   Results: The mean fracture resistance of R.T.D group was (1083.11 ± 156.74 (N and the mean of ICE light group was (865.18 ± 106.24 (N. The highest mean fracture resistance was observed in RTD fiberglass and a statistically significant difference was observed between the two groups (P<0.001.   Conclusion: FRC posts with zirconia coating due to unfavorable fractures of the teeth should be used with caution, and thus, fiber posts are preferred.

  16. Tensile toughness test and high temperature fracture analysis of thermal barrier coatings

    International Nuclear Information System (INIS)

    Qian, G.; Nakamura, T.; Berndt, C.C.; Leigh, S.H.

    1997-01-01

    In this paper, an effective fracture toughness test which uses interface fracture mechanics theory is introduced. This method is ideally suited for determining fracture resistance of multilayered thermal barrier coatings (TBCs) consisting of ceramic and bond layers and, unlike other fracture experiments, requires minimal set-up over a simple tensile adhesion test. Furthermore, while other test methods usually use edge cracked specimens, the present test models a crack embedded within the coatings, which is more consistent with actual TBCs where failure initiates from internal voids or defects. The results of combined computational and experimental analysis show that any defects located within the ceramic coating can significantly weaken a TBC, whereas the debonding resistances of the bond coating and its interfaces are found to be much higher. In a separate analysis, the authors have studied fracture behavior of TBCs subjected to thermal loading in a high temperature environment. The computed fracture parameters reveal that when the embedded crack size is on order of the coating thickness, the fracture driving force is comparable to the fracture resistance of the coating found in the toughness test. In addition, the major driving force for fracture derives from the thermal insulating effect across the crack faces rather than the mismatch in the coefficients of thermal expansion. The authors have also investigated the effects of functionally graded material (FGM) within TBCs and found its influences on the fracture parameters to be small. This result implies that the FGM may not contribute toward enhancing the fracture toughness of the TBCs considered here

  17. Fracture behaviour of heat cured fly ash based geopolymer concrete

    International Nuclear Information System (INIS)

    Sarker, Prabir K.; Haque, Rashedul; Ramgolam, Karamchand V.

    2013-01-01

    Highlights: ► Fly ash geopolymer (GPC) can help reduce carbon footprint of concrete. ► Fracture behaviour of GPC as compared to OPC concrete was studied. ► Fracture energy of GPC was similar to that of OPC concrete. ► GPC showed higher fracture toughness than OPC concrete. ► Higher bond strength resulted in higher crack resistance of GPC. -- Abstract: Use of fly ash based geopolymer as an alternative binder can help reduce CO 2 emission of concrete. The binder of geopolymer concrete (GPC) is different from that of ordinary Portland cement (OPC) concrete. Thus, it is necessary to study the effects of the geopolymer binder on the behaviour of concrete. In this study, the effect of the geopolymer binder on fracture characteristics of concrete has been investigated by three point bending test of RILEM TC 50 – FMC type notched beam specimens. The peak load was generally higher in the GPC specimens than the OPC concrete specimens of similar compressive strength. The failure modes of the GPC specimens were found to be more brittle with relatively smooth fracture planes as compared to the OPC concrete specimens. The post-peak parts of the load–deflection curves of GPC specimens were steeper than that of OPC concrete specimens. Fracture energy calculated by the work of fracture method was found to be similar in both types of concrete. Available equations for fracture energy of OPC concrete yielded conservative estimations of fracture energy of GPC. The critical stress intensity factor of GPC was found to be higher than that of OPC concrete. The different fracture behaviour of GPC is mainly because of its higher tensile strength and bond strength than OPC concrete of the same compressive strength.

  18. Comparison of fracture properties for two types of low alloy steels

    International Nuclear Information System (INIS)

    Nasreldin, A.M.

    2004-01-01

    The fracture properties of two types of low alloy steels used in the pressure vessel and boilers industry were determined. The first type was the steel A533-B which comprised a fully bainitic microstructure. The second one was the C-Mn steel which consisted of ferritic-pearlitic microstructure. The following fracture properties were determined using instrumented impact testing: the total fracture energy, the crack initiation and propagation energies, the brittleness transition temperature and the local fracture stress. The steel A533-B showed better fracture properties at high testing temperatures, while the C-Mn steel displayed higher resistance to brittle fracture at low testing temperatures. The results were discussed in relation to the difference in microstructure and fracture surface morphology for both steels

  19. Effect of adhesive luting on the fracture resistance of zirconia compared to that of composite resin and lithium disilicate glass ceramic

    Directory of Open Access Journals (Sweden)

    Myung-Jin Lim

    2017-02-01

    Full Text Available Objectives The purpose of this study was to evaluate the effect of adhesive luting on the fracture resistance of zirconia compared to that of a composite resin and a lithium disilicate glass ceramic. Materials and Methods The specimens (dimension: 2 mm × 2 mm × 25 mm of the composite resin, lithium disilicate glass ceramic, and yttria-stabilized tetragonal zirconia polycrystal (Y-TZP were prepared. These were then divided into nine groups: three non-luting groups, three non-adhesive luting groups, and three adhesive luting groups, for each restorative material. In the non-luting groups, specimens were placed on the bovine tooth without any luting agents. In the non-adhesive luting groups, only zinc phosphate cement was used for luting the specimen to the bovine tooth. In the adhesive luting groups, specimens were pretreated, and the adhesive luting procedure was performed using a self-adhesive resin cement. For all the groups, a flexural test was performed using universal testing machine, in which the fracture resistance was measured by recording the force at which the specimen was fractured. Results The fracture resistance after adhesive luting increased by approximately 29% in the case of the composite resin, 26% in the case of the lithium disilicate glass ceramic, and only 2% in the case of Y-TZP as compared to non-adhesive luting. Conclusions The fracture resistance of Y-TZP did not increased significantly after adhesive luting as compared to that of the composite resin and the lithium disilicate glass ceramic.

  20. In vitro evaluation of fracture resistance of Fiber-Reinforced Composite inlay bridges in upper anterior and lower posterior teeth

    Directory of Open Access Journals (Sweden)

    Jalalian E.

    2007-07-01

    Full Text Available Background and Aim: Considering flexural strength of fiber-reinforced composites (FRC and also the role of conservative cavities in protecting sound tissue of abutments, the aim of this study was to evaluate the fracture resistance of these bridges by handmade samples in vitro.Materials and Methods: In this experimental in vitro study, 44 sound newly extracted teeth were used to make 22 fixed inlay bridges including 11 three unit anterior upper inlay bridges substituting clinical model of upper central and 11 three unit posterior lower inlay bridges substituting clinical model of lower first molar. Specimens were prepared with FRC and mounted with artificial PDL in acryl. Cases were exposed to final load by using Universal Testing Machine (Instron 1195 with the speed of 1 mm/min. Statistical analysis was performed by Kolmogorov- Smirnov, independent sample T and Kaplan-Meier tests with p<0.05 as the level of significance.Results: Based on the statistical tests, the 95% confidence interval of mean was 450-562 N in anterior and  1473- 1761 N in posterior area. Fracture strength was high in the studied groups. Fractures in both groups occurred on composite facing, and the framework remained intact. The highest percentage of fracture in posterior teeth was in the middle of pontic towards the distal connector and in the anterior teeth in the lateral connector, between central pontic and lateral abutment. Using the independent sample T  test a significant statistical difference was observed between two groups (P<0.001. The fracture resistance of anterior samples was lower than the posterior ones.Conclusion: Based on the results of this study regarding the high fracture resistance in both areas FRC inlay bridges could be recommended for upper anterior and lower posterior teeth in clinical dentistry certainly more studies are needed to ascertain this treatment option.

  1. Fracture resistance of endodontically treated teeth restored with short fiber composite used as a core material-An in vitro study.

    Science.gov (United States)

    Garlapati, Tejesh Gupta; Krithikadatta, Jogikalmat; Natanasabapathy, Velmurugan

    2017-10-01

    This in-vitro study tested the fracture resistance of endodontically treated molars with Mesial-Occluso-Distal (MOD) cavities restored with fibre reinforced composite material everX posterior in comparision with hybrid composite and ribbond fiber composite. Fifty intact freshly extracted human mandibular first molars were collected and were randomly divided into five groups (n=10). Group 1: positive control (PC) intact teeth without any endodontic preparation. In groups 2 through 6 after endodontic procedure standard MOD cavities were prepared and restored with their respective core materials as follows: group 2, negative control (NC) left unrestored or temporary flling was applied. Group 3, Hybrid composite (HC) as a core material (Te-Econom Plus Ivoclar Vivadent Asia) group 4, Ribbond (Ribbond; Seattle, WA, USA)+conventional composite resin (RCR) group 5, everX posterior (everX Posterior GC EUROPE)+conventional composite resin (EXP) after thermocycling fracture resistance for the samples were tested using universal testing machine. The results were analysed using ANOVA and Tukey's HSD post hoc tests. Mean fracture resistance (in Newton, N) was group 1: 1568.4±221.71N, group 2: 891.0±50.107N, group 3: 1418.3±168.71N, group 4:1716.7±199.51N and group 5: 1994.8±254.195N. Among the materials tested, endodontically treated teeth restored with everX posterior fiber reinforced composite showed superior fracture resistance. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  2. Effect of Fiber Layers on the Fracture Resistance of Fiber Reinforced Composite Bridges

    Directory of Open Access Journals (Sweden)

    A Fazel

    2011-08-01

    Full Text Available Introduction: The purpose of this in vitro study was to introduce the fiber reinforced composite bridges and evaluate the most suitable site and position for placement of fibers in order to get maximum strength. Methods: The study included 20 second premolars and 20 second molars selected for fabricating twenty fiber reinforced composite bridges. Twenty specimens were selected for one fiber layer and the remaining teeth for two fiber layers. In the first group, fibers were placed in the inferior third and in the second group, fibers were placed in both the middle and inferior third region. After tooth preparation, the restorations were fabricated, thermocycled and then loaded with universal testing machine in the middle of the pontics with crosshead speed of 1mm/min. Data was analyzed by Kolmogorov-Smirnov test, Independent sample t test and Kaplan-Meier test. Mode of failure was evaluated using stereomicroscope. Results: Mean fracture resistance for the first and second groups was 1416±467N and 1349±397N, respectively. No significant differences were observed between the groups (P>0.05.In the first group, 5 specimens had delamintation and 5 specimens had detachment between fibers and resin composite. In the second group, there were 4 and 6 delaminations and detachments, respectively. There was no fracture within the fiber. Conclusion: In the fiber reinforced fixed partial dentures, fibers reinforce the tensile side of the connectors but placement of additional fibers at other sites does not increase the fracture resistance of the restoration.

  3. Divergent effects of obesity on fragility fractures

    Directory of Open Access Journals (Sweden)

    Caffarelli C

    2014-09-01

    Full Text Available Carla Caffarelli, Chiara Alessi, Ranuccio Nuti, Stefano Gonnelli Department of Medicine, Surgery and Neuroscience, University of Siena, Siena, Italy Abstract: Obesity was commonly thought to be advantageous for maintaining healthy bones due to the higher bone mineral density observed in overweight individuals. However, several recent studies have challenged the widespread belief that obesity is protective against fracture and have suggested that obesity is a risk factor for certain fractures. The effect of obesity on fracture risk is site-dependent, the risk being increased for some fractures (humerus, ankle, upper arm and decreased for others (hip, pelvis, wrist. Moreover, the relationship between obesity and fracture may also vary by sex, age, and ethnicity. Risk factors for fracture in obese individuals appear to be similar to those in nonobese populations, although patterns of falling are particularly important in the obese. Research is needed to determine if and how visceral fat and metabolic complications of obesity (type 2 diabetes mellitus, insulin resistance, chronic inflammation, etc are causally associated with bone status and fragility fracture risk. Vitamin D deficiency and hypogonadism may also influence fracture risk in obese individuals. Fracture algorithms such as FRAX® might be expected to underestimate fracture probability. Studies specifically designed to evaluate the antifracture efficacy of different drugs in obese patients are not available; however, literature data may suggest that in obese patients higher doses of the bisphosphonates might be required in order to maintain efficacy against nonvertebral fractures. Therefore, the search for better methods for the identification of fragility fracture risk in the growing population of adult and elderly subjects with obesity might be considered a clinical priority which could improve the prevention of fracture in obese individuals. Keywords: bone mineral density, BMI

  4. Fracture resistance of direct inlay-retained adhesive bridges : Effect of pontic material and occlusal morphology

    NARCIS (Netherlands)

    Breuklander, Marijn; Salihoglu-Yener, Esra; Ozcan, Mutlu

    This study evaluated the effect of a) pontic materials and b) occlusal morphologies on the fracture resistance of fiber-reinforced composite (FRC) inlay-retained fixed dental prostheses (FDP). Inlay-retained FRC FPDs (N=45, n=9) were constructed using a) resin composite (deep anatomy), b) natural

  5. Gradients in fracture force and grazing resistance across canopy layers in seven tropical grass species

    NARCIS (Netherlands)

    Jacobs, A.A.A.; Scheper, J.A.; Benvenutti, M.A.; Gordon, I.J.; Poppi, D.P.; Elgersma, A.

    2013-01-01

    In reproductive swards, stems can act as a barrier that affects the grazing behaviour of ruminant livestock. The barrier effect of stems is closely associated with both the force required to fracture the stems and the density of these stems (in combination, these make up grazing resistance), and

  6. Br-rich tips of calcified crab claws are less hard but more fracture resistant: a comparison of mineralized and heavy-element biological materials.

    Science.gov (United States)

    Schofield, Robert M S; Niedbala, Jack C; Nesson, Michael H; Tao, Ye; Shokes, Jacob E; Scott, Robert A; Latimer, Matthew J

    2009-06-01

    We find that the spoon-like tips of the chelipeds (large claws) of the crab Pachygrapsus crassipes differ from the rest of the claw in that they are not calcified, but instead contain about 1% bromine--thus they represent a new example of a class of structural biological materials that contain heavy elements such as Zn, Mn, Fe, Cu, and Br bound in an organic matrix. X-ray absorption spectroscopy data suggest that the bromine is bound to phenyl rings, possibly in tyrosine. We measure a broad array of mechanical properties of a heavy-element biological material for the first time (abrasion resistance, coefficient of kinetic friction, energy of fracture, hardness, modulus of elasticity and dynamic mechanical properties), and we make a direct comparison with a mineralized tissue. Our results suggest that the greatest advantage of bromine-rich cuticle over calcified cuticle is resistance to fracture (the energy of fracture is about an order of magnitude greater than for calcified cuticle). The greatest advantage relative to unenriched cuticle, represented by ant mandible cuticle, is a factor of about 1.5 greater hardness and modulus of elasticity.The spoon-like tips gain additional fracture resistance from the orientation of the constituent laminae and from the viscoelasticity of the material. We suggest that fracture resistance is of greater importance in smaller organisms, and we speculate that one function of heavy elements in structural biological materials is to reduce molecular resonant frequencies and thereby increase absorption of energy from impacts.

  7. Effect of fiber post length and abutment height on fracture resistance of endodontically treated premolars prepared for zirconia crowns.

    Science.gov (United States)

    Lin, Jie; Matinlinna, Jukka Pekka; Shinya, Akikazu; Botelho, Michael George; Zheng, Zhiqiang

    2018-04-01

    The purpose of this study was to compare the fracture resistance, mode of fracture, and stress distribution of endodontically treated teeth prepared with three different fiber post lengths and two different abutment heights, using both experimental and finite element (FE) approaches. Forty-eight human maxillary premolars with two roots were selected and endodontically treated. The teeth were randomly distributed into six equally sized groups (n = 8) with different combinations of post lengths (7.5, 11, and 15 mm) and abutment heights (3 and 5 mm). All the teeth restored with glass fiber post (Rely X Fiber Post, 3M ESPE, USA) and a full zirconia crown. All the specimens were thermocycled and then loaded to failure at an oblique angle of 135°. Statistical analysis was performed for the effects of post length and abutment height on failure loads using ANOVA and Tukey's honestly significant difference test. In addition, corresponding FE models of a premolar restored with a glass fiber post were developed to examine mechanical responses. The factor of post length (P abutment height (P > 0.05) did not have a significant effect on failure load. The highest mean fracture resistance was recorded for the 15 mm post length and 5 mm abutment height test group, which was significantly more resistant to fracture than the 7.5 mm post and 5 mm abutment height group (P abutment heights.

  8. Fracture resistance of dental nickel–titanium rotary instruments with novel surface treatment: Thin film metallic glass coating

    Directory of Open Access Journals (Sweden)

    Chih-Wen Chi

    2017-05-01

    Conclusion: The novel surface treatment of Ti-Zr-B thin film metallic glass on dental NiTi rotary files can effectively improve the fatigue fracture resistance by offering a smooth coated surface with amorphous microstructure.

  9. Edge chipping and flexural resistance of monolithic ceramics☆

    Science.gov (United States)

    Zhang, Yu; Lee, James J.-W.; Srikanth, Ramanathan; Lawn, Brian R.

    2014-01-01

    Objective Test the hypothesis that monolithic ceramics can be developed with combined esthetics and superior fracture resistance to circumvent processing and performance drawbacks of traditional all-ceramic crowns and fixed-dental-prostheses consisting of a hard and strong core with an esthetic porcelain veneer. Specifically, to demonstrate that monolithic prostheses can be produced with a much reduced susceptibility to fracture. Methods Protocols were applied for quantifying resistance to chipping as well as resistance to flexural failure in two classes of dental ceramic, microstructurally-modified zirconias and lithium disilicate glass–ceramics. A sharp indenter was used to induce chips near the edges of flat-layer specimens, and the results compared with predictions from a critical load equation. The critical loads required to produce cementation surface failure in monolithic specimens bonded to dentin were computed from established flexural strength relations and the predictions validated with experimental data. Results Monolithic zirconias have superior chipping and flexural fracture resistance relative to their veneered counterparts. While they have superior esthetics, glass–ceramics exhibit lower strength but higher chip fracture resistance relative to porcelain-veneered zirconias. Significance The study suggests a promising future for new and improved monolithic ceramic restorations, with combined durability and acceptable esthetics. PMID:24139756

  10. Resistance to change in Greek higher education

    OpenAIRE

    Kremmyda, Stamatia

    2015-01-01

    This thesis is a study of resistance to the changes in Greek higher education that were implemented within the framework of the 1999 Bologna Agreement of the European Union in the period 2007-2008. The changes that occurred were of great significance for Greece’s education system as they introduced important changes in the structure and function of Greek higher education. This thesis argues that the organisational culture that had been created throughout the history of Greek higher education ...

  11. CSA-90 Promotes Bone Formation and Mitigates Methicillin-resistant Staphylococcus aureus Infection in a Rat Open Fracture Model.

    Science.gov (United States)

    Mills, Rebecca; Cheng, Tegan L; Mikulec, Kathy; Peacock, Lauren; Isaacs, David; Genberg, Carl; Savage, Paul B; Little, David G; Schindeler, Aaron

    2018-06-01

    Infection of open fractures remains a significant cause of morbidity and mortality to patients worldwide. Early administration of prophylactic antibiotics is known to improve outcomes; however, increasing concern regarding antimicrobial resistance makes finding new compounds for use in such cases a pressing area for further research. CSA-90, a synthetic peptidomimetic compound, has previously demonstrated promising antimicrobial action against Staphylococcus aureus in rat open fractures. However, its efficacy against antibiotic-resistant microorganisms, its potential as a therapeutic agent in addition to its prophylactic effects, and its proosteogenic properties all require further investigation. (1) Does prophylactic treatment with CSA-90 reduce infection rates in a rat open fracture model inoculated with S aureus, methicillin-resistant S aureus (MRSA), and methicillin-resistant Staphylococcus epidermidis (MRSE) as measured by survival, radiographic union, and deep tissue swab cultures? (2) Does CSA-90 reduce infection rates when administered later in the management of an open fracture as measured by survival, radiographic union, and deep tissue swab cultures? (3) Does CSA-90 demonstrate a synergistic proosteogenic effect with bone morphogenetic protein 2 (BMP-2) in a noninfected rat ectopic bone formation assay as assessed by micro-CT bone volume measurement? (4) Can CSA-90 elute and retain its antimicrobial efficacy in vitro when delivered using clinically relevant agents measured using a Kirby-Bauer disc diffusion assay? All in vivo studies were approved by the local animal ethics committee. In the open fracture studies, 12-week-old male Wistar rats underwent open midshaft femoral fractures stabilized with a 1.1-mm Kirschner wire and 10 µg BMP-2 ± 500 µg CSA-90 was applied to the fracture site using a collagen sponge along with 1 x 10 colony-forming units of bacteria (S aureus/MRSA/MRSE; n = 10 per group). In the delayed treatment study, débridement and

  12. Electrical resistivity dynamics beneath a fractured sedimentary bedrock riverbed in response to temperature and groundwater–surface water exchange

    Directory of Open Access Journals (Sweden)

    C. M. Steelman

    2017-06-01

    Full Text Available Bedrock rivers occur where surface water flows along an exposed rock surface. Fractured sedimentary bedrock can exhibit variable groundwater residence times, anisotropic flow paths, and heterogeneity, along with diffusive exchange between fractures and rock matrix. These properties of the rock will affect thermal transients in the riverbed and groundwater–surface water exchange. In this study, surface electrical methods were used as a non-invasive technique to assess the scale and temporal variability of riverbed temperature and groundwater–surface water interaction beneath a sedimentary bedrock riverbed. Conditions were monitored at a semi-daily to semi-weekly interval over a full annual period that included a seasonal freeze–thaw cycle. Surface electromagnetic induction (EMI and electrical resistivity tomography (ERT methods captured conditions beneath the riverbed along a pool–riffle sequence of the Eramosa River in Canada. Geophysical datasets were accompanied by continuous measurements of aqueous specific conductance, temperature, and river stage. Time-lapse vertical temperature trolling within a lined borehole adjacent to the river revealed active groundwater flow zones along fracture networks within the upper 10 m of rock. EMI measurements collected during cooler high-flow and warmer low-flow periods identified a spatiotemporal riverbed response that was largely dependent upon riverbed morphology and seasonal groundwater temperature. Time-lapse ERT profiles across the pool and riffle sequence identified seasonal transients within the upper 2 and 3 m of rock, respectively, with spatial variations controlled by riverbed morphology (pool versus riffle and dominant surficial rock properties (competent versus weathered rock rubble surface. While the pool and riffle both exhibited a dynamic resistivity through seasonal cooling and warming cycles, conditions beneath the pool were more variable, largely due to the formation of river

  13. Plastic fracture mechanics prediction of fracture instability in a circumferentially cracked pipe in bending - 1. J-integral analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zahoor, A.; Kanninen, M.F.

    1981-11-01

    A method of evaluating the J-integral for a circumferentially cracked pipe in bending is proposed. The method allows a J-resistance curve to be evaluated directly from the load-displacement record obtained in a pipe fracture experiment. It permits an analysis for fracture instability in a circumferential crack growth using a J-resistance curve and the tearing modulus parameter. The influence of the system compliance on fracture instability is discussed in conjunction with the latter application. The importance of using a J-resistance curve that is consistent with the type of constraint for a given application is emphasized. The possibility of a pipe fracture emanating from a stress corrosion crack in the heat-affected zones of girth-welds in Type 304 stainless steel pipes was investigated. The J-resistance curve was employed. A pipe fracture experiment was performed using a spring-loaded four-point bending system that simulated an 8.8-m long section of unsupported 102-mm-dia pipe. An initial through-wall crack of length equal to 104 mm was used. Fracture instability was predicted to occur between 15.2 and 22.1 mm of stable crack growth at each tip. In the actual experiment, the onset of fracture instability occurred beyond maximum load at an average stable crack growth of 11.7 to 19 mm at each tip. 24 refs.

  14. Plastic fracture mechanics prediction of fracture instability in a circumferentially cracked pipe in bending - 1. J-integral analysis

    International Nuclear Information System (INIS)

    Zahoor, A.; Kanninen, M.F.

    1981-01-01

    A method of evaluating the J-integral for a circumferentially cracked pipe in bending is proposed. The method allows a J-resistance curve to be evaluated directly from the load-displacement record obtained in a pipe fracture experiment. It permits an analysis for fracture instability in a circumferential crack growth using a J-resistance curve and the tearing modulus parameter. The influence of the system compliance on fracture instability is discussed in conjunction with the latter application. The importance of using a J-resistance curve that is consistent with the type of constraint for a given application is emphasized. The possibility of a pipe fracture emanating from a stress corrosion crack in the heat-affected zones of girth-welds in Type 304 stainless steel pipes was investigated. The J-resistance curve was employed. A pipe fracture experiment was performed using a spring-loaded four-point bending system that simulated an 8.8-m long section of unsupported 102-mm-dia pipe. An initial through-wall crack of length equal to 104 mm was used. Fracture instability was predicted to occur between 15.2 and 22.1 mm of stable crack growth at each tip. In the actual experiment, the onset of fracture instability occurred beyond maximum load at an average stable crack growth of 11.7 to 19 mm at each tip. 24 refs

  15. Influence of periodontal ligament simulation on bond strength and fracture resistance of roots restored with fiber posts

    Directory of Open Access Journals (Sweden)

    Ana Maria Estivalete MARCHIONATTI

    2014-10-01

    Full Text Available Objective: Considering that periodontal ligament simulation may influence the stress distribution over teeth restored with intraradicular retainers, this study aimed to assess the combined effect of mechanical cycling and periodontal ligament simulation on both the bond strength between fiber posts and root dentin and the fracture resistance of teeth restored using glass fiber posts. Material and Methods: Ninety roots were randomly distributed into 3 groups (n=10 (C-MC: control; P-MC: polyether; AS-MC: addition silicone to test bond strength and 6 groups (n=10 (C: control; P: polyether; AS: addition silicone, without mechanical cycling, and C-MC, P-MC and AS-MC with mechanical cycling to test fracture strength, according to the material used to simulate the periodontal ligament. For the bond strength test, fiber posts were cemented, cores were built, mechanical cycling was applied (2×106 cycles, 88 N, 2.2 Hz, and 45º incline, and the teeth cut into 3 slices (2 mm, which were then subjected to the push-out test at 1 mm/min. For the fracture strength test, fiber posts were cemented, cores were built, and half of the groups received mechanical cycling, followed by the compressive strength (45° to the long axis and 1 mm/min performed on all groups. Results: Periodontal ligament simulation did not affect the bond strength (p=0.244 between post and dentin. Simulation of periodontal ligament (p=0.153 and application of mechanical cycling (p=0.97 did not affect fracture resistance. Conclusions: The materials used to simulate the periodontal ligament did not affect fracture or bond strength, therefore periodontal ligament simulation using the tested materials could be considered optional in the conditions of the study.

  16. Ex vivo fracture resistance of direct resin composite complete crowns with and without posts on maxillary premolars.

    NARCIS (Netherlands)

    Fokkinga, W.A.; Bell, A.M. Le; Kreulen, C.M.; Lassila, L.V.; Vallittu, P.K.; Creugers, N.H.J.

    2005-01-01

    AIM: To investigate ex vivo the fracture resistance and failure mode of direct resin composite complete crowns with and without various root canal posts made on maxillary premolars. METHODOLOGY: The clinical crowns of 40 human extracted single-rooted maxillary premolars were sectioned at the

  17. Numerical simulation and fracture identification of dual laterolog in organic shale

    Science.gov (United States)

    Maojin, Tan; Peng, Wang; Qiong, Liu

    2012-09-01

    Fracture is one of important spaces in shale oil and shale gas reservoirs, and fractures identification and evaluation are an important part in organic shale interpretation. According to the fractured shale gas reservoir, a physical model is set up to study the dual laterolog logging responses. First, based on the principle of dual laterolog, three-dimensional finite element method (FEM) is used to simulate the dual laterolog responses in various formation models with different fractures widths, different fracture numbers, different fractures inclination angle. All the results are extremely important for the fracture identification and evaluation in shale reservoirs. Appointing to different base rock resistivity models, the fracture models are constructed respectively through a number of numerical simulation, and the fracture porosity can be calculated by solving the corresponding formulas. A case study about organic shale formation is analyst and discussed, and the fracture porosity is calculated from dual laterolog. The fracture evaluation results are also be validated right by Full borehole Micro-resistivity Imaging (FMI). So, in case of the absence of borehole resistivity imaging log, the dual laterolog resistivity can be used to estimate the fracture development.

  18. Comparison of the fracture resistance of dental implants with different abutment taper angles.

    Science.gov (United States)

    Wang, Kun; Geng, Jianping; Jones, David; Xu, Wei

    2016-06-01

    To investigate the effects of abutment taper angles on the fracture strength of dental implants with TIS (taper integrated screwed-in) connection. Thirty prototype cylindrical titanium alloy 5.0mm-diameter dental implants with different TIS-connection designs were divided into six groups and tested for their fracture strength, using a universal testing machine. These groups consisted of combinations of 3.5 and 4.0 mm abutment diameter, each with taper angles of 6°, 8° or 10°. 3-Dimensional finite element analysis (FEA) was also used to analyze stress states at implant-abutment connection areas. In general, the mechanical tests found an increasing trend of implant fracture forces as the taper angle enlarged. When the abutment diameter was 3.5 mm, the mean fracture forces for 8° and 10° taper groups were 1638.9 N ± 20.3 and 1577.1 N ± 103.2, respectively, both larger than that for the 6° taper group of 1475.0 N ± 24.4, with the largest increasing rate of 11.1%. Furthermore, the difference between 8° and 6° taper groups was significant, based on Tamhane's multiple comparison test (Pabutment groups, as the taper angle was enlarged from 6° to 8° and 10°, the mean fracture value was increased from 1066.7 N ± 56.1 to 1241.4 N ± 6.4 and 1419.3 N ± 20.0, with the largest increasing rate of 33.1%, and the differences among the three groups were significant (Pabutment taper angles and supported the findings of the static tests. In conclusion, increases of the abutment taper angle could significantly increase implant fracture resistance in most cases established in the study, which is due to the increased implant wall thickness in the connection part resulting from the taper angle enlargement. The increasing effects were notable when a thin implant wall was present to accommodate wide abutments. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Effect of implantoplasty on fracture resistance and surface roughness of standard diameter dental implants.

    Science.gov (United States)

    Costa-Berenguer, Xavier; García-García, Marta; Sánchez-Torres, Alba; Sanz-Alonso, Mariano; Figueiredo, Rui; Valmaseda-Castellón, Eduard

    2018-01-01

    To assess the effect of implantoplasty on the fracture resistance, surface roughness, and macroscopic morphology of standard diameter (4.1 mm) external connection dental implants. An in vitro study was conducted in 20 screw-shaped titanium dental implants with an external connection. In 10 implants, the threads and surface were removed and polished with high-speed burs (implantoplasty), while the remaining 10 implants were used as controls. The final implant dimensions were recorded. The newly polished surface quality was assessed by scanning electron microscopy (SEM) and by 3D surface roughness analysis using a confocal laser microscope. Finally, all the implants were subjected to a mechanical pressure resistance test. A descriptive analysis of the data was made. Also, Student's t tests were employed to detect differences regarding the compression tests. Implantoplasty was carried out for a mean time of 10 min and 48 s (standard deviation (SD) of 1 min 22 s). Macroscopically, the resulting surface had a smooth appearance, although small titanium shavings and silicon debris were present. The final surface roughness (S a values 0.1 ± 0.02 μm) was significantly lower than that of the original (0.75 ± 0.08 μm S a ) (p = .005). There was minimal reduction in the implant's inner body diameter (0.19 ± 0.03 mm), and no statistically significant differences were found between the test and control implants regarding the maximum resistance force (896 vs 880 N, respectively). Implantoplasty, although technically demanding and time-consuming, does not seem to significantly alter fracture resistance of standard diameter external connection implants. A smooth surface with S a values below 0.1 μm can be obtained through the use of silicon polishers. A larger sample is required to confirm that implantoplasty does not significantly affect the maximum resistance force of standard diameter external connection implants. © 2017 John Wiley & Sons A/S. Published

  20. Fatigue and Fracture Resistance of Heavy-Section Ferritic Ductile Cast Iron

    Directory of Open Access Journals (Sweden)

    Matteo Benedetti

    2017-03-01

    Full Text Available In this paper, we explore the effect of a long solidification time (12 h on the mechanical properties of an EN-GJS-400-type ferritic ductile cast iron (DCI. For this purpose, static tensile, rotating bending fatigue, fatigue crack growth and fracture toughness tests are carried out on specimens extracted from the same casting. The obtained results are compared with those of similar materials published in the technical literature. Moreover, the discussion is complemented with metallurgical and fractographic analyses. It has been found that the long solidification time, representative of conditions arising in heavy-section castings, leads to an overgrowth of the graphite nodules and a partial degeneration into chunky graphite. With respect to minimum values prescribed for thick-walled (t > 60 mm EN-GJS-400-15, the reduction in tensile strength and total elongation is equal to 20% and 75%, respectively. The rotating bending fatigue limit is reduced by 30% with respect to the standard EN-1563, reporting the results of fatigue tests employing laboratory samples extracted from thin-walled castings. Conversely, the resistance to fatigue crack growth is even superior and the fracture toughness comparable to that of conventional DCI.

  1. Fracture toughness of the F-82H steel-effect of loading modes, hydrogen, and temperature

    International Nuclear Information System (INIS)

    Li, H.-X.; Jones, R.H.; Hirth, J.P.; Gelles, D.S.

    1996-01-01

    The effects of loading mode, hydrogen, and temperature on fracture toughness and tearing modulus were examined for a ferritic/martensitic steel (F-82H). The introduction of a shear load component, mode III, significantly decreased the initiation and propagation resistance of cracks compared to the opening load, mode I, behavior. Mode I crack initiation and propagation exhibited the highest resistance. A minimum resistance occurred when the mode I and mode III loads were nearly equal. The presence of 4 wppm hydrogen decreased the cracking resistance compared to behavior without H regardless of the loading mode. The minimum mixed-mode fracture toughness with the presence of hydrogen was about 30% of the hydrogen-free mode I fracture toughness. The mixed-mode toughness exhibited a lesser sensitivity to temperature than the mode I toughness. The J IC value was 284 kJ/m 2 at room temperature, but only 60 kJ/m 2 at -55 C and 30 kJ/m 2 at -90 C. The ductile to brittle transition temperature (DBTT) was apparently higher than -55 C. (orig.)

  2. Fracture Resistance of Endodontically Treated Teeth Restored with Biodentine, Resin Modified GIC and Hybrid Composite Resin as a Core Material.

    Science.gov (United States)

    Subash, Dayalan; Shoba, Krishnamma; Aman, Shibu; Bharkavi, Srinivasan Kumar Indu; Nimmi, Vijayan; Abhilash, Radhakrishnan

    2017-09-01

    The restoration of a severely damaged tooth usually needs a post and core as a part of treatment procedure to provide a corono - radicular stabilization. Biodentine is a class of dental material which possess high mechanical properties with excellent biocompatibility and bioactive behaviour. The sealing ability coupled with optimum physical properties could make Biodentine an excellent option as a core material. The aim of the study was to determine the fracture resistance of Biodentine as a core material in comparison with resin modified glass ionomer and composite resin. Freshly extracted 30 human permanent maxillary central incisors were selected. After endodontic treatment followed by post space preparation and luting of Glass fibre post (Reforpost, Angelus), the samples were divided in to three groups based on the type of core material. The core build-up used in Group I was Biodentine (Septodont, France), Group II was Resin-Modified Glass Ionomer Cement (GC, Japan) and Group III was Hybrid Composite Resin (TeEconom plus, Ivoclar vivadent). The specimens were subjected to fracture toughness using Universal testing machine (1474, Zwick/Roell, Germany) and results were compared using One-way analysis of variance with Tukey's Post hoc test. The results showed that there was significant difference between groups in terms of fracture load. Also, composite resin exhibited highest mean fracture load (1039.9 N), whereas teeth restored with Biodentine demonstrated the lowest mean fracture load (176.66 N). Resin modified glass ionomer exhibited intermediate fracture load (612.07 N). The primary mode of failure in Group I and Group II was favourable (100%) while unfavourable fracture was seen in Group III (30%). Biodentine, does not satisfy the requirements to be used as an ideal core material. The uses of RMGIC's as a core build-up material should be limited to non-stress bearing areas. Composite resin is still the best core build-up material owing to its high fracture

  3. Fracture and Fatigue Resistance of Cemented versus Fused CAD-on Veneers over Customized Zirconia Implant Abutments.

    Science.gov (United States)

    Nossair, Shereen Ahmed; Aboushelib, Moustafa N; Morsi, Tarek Salah

    2015-01-05

    To evaluate the fracture mechanics of cemented versus fused CAD-on veneers on customized zirconia implant abutments. Forty-five identical customized CAD/CAM zirconia implant abutments (0.5 mm thick) were prepared and seated on short titanium implant abutments (Ti base). A second scan was made to fabricate 45 CAD-on veneers (IPS Empress CAD, A2). Fifteen CAD-on veneers were cemented on the zirconia abutments (Panavia F2.0). Another 15 were fused to the zirconia abutments using low-fusing glass, while manually layered veneers served as control (n = 15). The restorations were subjected to artificial aging (3.2 million cycles between 5 and 10 kg in a water bath at 37°C) before being axially loaded to failure. Fractured specimens were examined using scanning electron microscopy to detect fracture origin, location, and size of critical crack. Stress at failure was calculated using fractography principles (alpha = 0.05). Cemented CAD-on restorations demonstrated significantly higher (F = 72, p CAD-on and manually layered restorations. Fractographic analysis of fractured specimens indicated that cemented CAD-on veneers failed due to radial cracks originating from the veneer/resin interface. Branching of the critical crack was observed in the bulk of the veneer. Fused CAD-on veneers demonstrated cohesive fracture originating at the thickest part of the veneer ceramic, while manually layered veneers failed due to interfacial fracture at the zirconia/veneer interface. Within the limitations of this study, cemented CAD-on veneers on customized zirconia implant abutments demonstrated higher fracture than fused and manually layered veneers. © 2014 by the American College of Prosthodontists.

  4. Resistance to compression of weakened roots subjected to different root reconstruction protocols

    Directory of Open Access Journals (Sweden)

    Lucas Villaça Zogheib

    2011-12-01

    Full Text Available OBJECTIVE: This study evaluated, in vitro, the fracture resistance of human non-vital teeth restored with different reconstruction protocols. MATERIAL AND METHODS: Forty human anterior roots of similar shape and dimensions were assigned to four groups (n=10, according to the root reconstruction protocol: Group I (control: non-weakened roots with glass fiber post; Group II: roots with composite resin by incremental technique and glass fiber post; Group III: roots with accessory glass fiber posts and glass fiber post; and Group IV: roots with anatomic glass fiber post technique. Following post cementation and core reconstruction, the roots were embedded in chemically activated acrylic resin and submitted to fracture resistance testing, with a compressive load at an angle of 45º in relation to the long axis of the root at a speed of 0.5 mm/min until fracture. All data were statistically analyzed with bilateral Dunnett's test (α=0.05. RESULTS: Group I presented higher mean values of fracture resistance when compared with the three experimental groups, which, in turn, presented similar resistance to fracture among each other. None of the techniques of root reconstruction with intraradicular posts improved root strength, and the incremental technique was suggested as being the most recommendable, since the type of fracture that occurred allowed the remaining dental structure to be repaired. CONCLUSION: The results of this in vitro study suggest that the healthy remaining radicular dentin is more important to increase fracture resistance than the root reconstruction protocol.

  5. Post-ischemic stroke rehabilitation is associated with a higher risk of fractures in older women: A population-based cohort study.

    Science.gov (United States)

    Huang, Huei Kai; Lin, Shu Man; Yang, Clement Shih Hsien; Liang, Chung Chao; Cheng, Hung Yu

    2017-01-01

    Rehabilitation can improve physical activity after stroke. However, patients may be more prone to falls and fractures because of balance and gait deficits. Few reports have studied the relationship between rehabilitation and subsequent fractures after ischemic stroke. To investigate whether post-stroke rehabilitation affects fracture risk. We conducted a population-based retrospective cohort study based on the Taiwan National Health Insurance Research Database. Patients with a newly diagnosed ischemic stroke between 2000 and 2012 were included. After propensity score matching, a total of 8,384 patients were enrolled. Half of the patients (4,192) received post-stroke rehabilitation within 1 month; the other half did not receive any post-stroke rehabilitation. Cox proportional hazards regression model was used to calculate hazard ratios (HRs) for fractures among patients with and without rehabilitation within 1 year after ischemic stroke. Patients were further stratified by sex and age (20-64 and ≥65 years). Patients receiving post-stroke rehabilitation had a higher incidence of fracture (6.2 per 100 person-years) than those who did not (4.1 per 100 person-years) after adjustment for sociodemographic and coexisting medical conditions [HR = 1.53, 95% confidence interval (CI) = 1.25-1.87, p rehabilitation had a significantly higher risk of fracture (HR = 1.62, 95% CI = 1.21-2.17, p = 0.001). Rehabilitation after ischemic stroke is associated with an increased fracture risk in older women.

  6. Fracture resistance of zirconia-based implant abutments after artificial long-term aging.

    Science.gov (United States)

    Alsahhaf, Abdulaziz; Spies, Benedikt Christopher; Vach, Kirstin; Kohal, Ralf-Joachim

    2017-02-01

    To investigate the survival rate, fracture strength, bending moments, loading to fracture and fracture modes of different designs of zirconia abutments after dynamic loading with thermocycling, and compare these values to titanium abutments. A total of 80 abutment samples were divided into 5 test groups of 16 samples in each group. The study included the following groups, "Group 1" CAD/CAM produced all-zirconia abutments, "Group 2" titanium abutments, "Group 3" zirconia-abutments adhesively luted to a titanium base, "Group 4" prefabricated all-zirconia abutments and "Group 5" zirconia-abutments glass soldered to a titanium base. Half the number of samples in each group was exposed to 1.2 million loading cycles (5-years simulation) in the chewing simulator. The samples that survived the artificial aging were later tested for fracture strength in a universal testing machine. The remaining 8 samples of the group were directly tested for fracture strength. All samples exposed to the 5-years artificial aging survived except of six samples in one group (Group 1). The surviving samples were later fracture tested in the universal testing machine. The bending moments (Ncm) values were as follow: Exposed groups: "Group 1" 94.5Ncm; "Group 2" 599.2Ncm; "Group 3" 477.5Ncm; "Group 4" 314.4Ncm; "Group 5" 509.4Ncm. Non-exposed groups: "Group 1" 269.3Ncm; "Group 2" 474.2Ncm; "Group 3" 377.6Ncm; "Group 4" 265.4Ncm; "Group 5" 372.4Ncm. Except in Group 1, the values were higher in the exposed groups, although, statistically there was no difference (p>0.05). The one-piece ZrO2-abutment group (Group 1 and Group 4) exhibited lower values, while the two-piece ZrO2-abutment groups (Group 3 and Group 5) showed similar values and fracture modes like the titanium abutment group. The titanium abutment group showed the highest values of bending moments among all groups. The implant-abutment connection area appeared to influence the bending moment value and the fracture mode of the tested

  7. Impact sports and bone fractures among adolescents.

    Science.gov (United States)

    Lynch, Kyle R; Kemper, Han C G; Turi-Lynch, Bruna; Agostinete, Ricardo R; Ito, Igor H; Luiz-De-Marco, Rafael; Rodrigues-Junior, Mario A; Fernandes, Rômulo A

    2017-12-01

    The objective of the present study was to investigate the effects of different sports on stress fractures among adolescents during a 9-month follow-up period. The sample was composed of 184 adolescents divided into three groups (impact sports [n = 102]; swimming [n = 35]; non-sports [n = 47]). The occurrence of stress fracture was reported by participants and coaches. As potential confounders we considered age, sex, resistance training, body composition variables and age at peak of height velocity. There were 13 adolescents who reported fractures during the 9-month period. Bone mineral density values were higher in adolescents engaged in impact sports (P-value = 0.002). Independently of confounders, the risk of stress fracture was lower in adolescents engaged in impact sports than in non-active adolescents (hazard ratio [HR] = 0.23 [95% confidence interval (CI) = 0.05 to 0.98]), while swimming practice was not associated to lower risk of fracture (HR = 0.49 [95% CI = 0.09 to 2.55]). In conclusion, the findings from this study indicate the importance of sports participation among adolescents in the reduction of stress fracture risk, especially with impact sports. More importantly, these results could be relevant for recognising adolescents in danger of not reaching their potential for peak bone mass and later an increased risk of fractures.

  8. Resistance of heat resisting steels and alloys to thermal and mechanical low-cycle fatigue

    International Nuclear Information System (INIS)

    Tulyakov, G.A.

    1980-01-01

    Carried out is a comparative evalUation of resistance of different materials to thermocyclic deformation and fracture on the base of the experimental data on thermal and mechanical low-cycle fatigUe. Considered are peculiarities of thermal fatigue resistance depending on strength and ductility of the material. It is shown, that in the range of the cycle small numbers before the fracture preference is given to the high-ductility cyclically strengthening austenitic steels of 18Cr-10Ni type with slight relation of yield strength to the σsub(0.2)/σsub(B) tensile strength Highly alloyed strength chromium-nickel steels, as well as cyclically destrengthening perlitic and ferritic steels with stronger σsub(0.2)/σsub(B) relation as compared with simple austenitic steels turn to be more long-lived in the range of the cycle great numbers berore fracture. Perlitic steels are stated to have the lowest parameter values of the K crack growth intensity under the similar limiting conditions of the experiment, while steels and alloys with austenite structure-higher values of the K parameter

  9. In vitro fracture resistance of molar teeth restored with a short fibre-reinforced composite material.

    Science.gov (United States)

    Fráter, Márk; Forster, András; Keresztúri, Márk; Braunitzer, Gábor; Nagy, Katalin

    2014-09-01

    The purpose of this in vitro study was to evaluate the efficiency of a short fibre-reinforced composite (SFRC) material compared to conventional composites when restoring class II. MOD cavities in molar teeth with different layering techniques. One hundred and thirty mandibular third molars were divided into 5 groups (n=26). Except for the control group (intact teeth), in all other groups MOD cavities were prepared. The cavities were restored by either conventional composite with horizontal and oblique layering or by SFRC with horizontal and oblique layering. The specimens were submitted to static fracture toughness test. Fracture thresholds and fracture patterns were evaluated. In general, no statistically significant difference was found in fracture toughness between the study groups, except for horizontally layered conventional composite restorations, which turned out to be significantly weaker than controls. However, SFRC yielded noticeably higher fracture thresholds and only obliquely applied SFRC restorations exhibited favourable fracture patterns above chance level. The application of SFRC did not lead to a statistically significant improvement of the fracture toughness of molar teeth with MOD cavities. Still, SFRC applied in oblique increments measurably reduces the chance of unrestorable fractures of molar teeth with class II MOD cavities. The restoration of severely weakened molar teeth with the use of SFRC combined with composite might have advantages over conventional composites alone. It was observed from the statistical data, that the application of SFRC with an oblique layering technique yielded not significantly but better fracture thresholds and more favourable fracture patterns than any other studied material/technique combination. Thus further investigations need to be carried out, to investigate the possible positive mechanical effects of SFRC. The application of the horizontal layering technique with conventional composite materials is inferior

  10. Poor nutritional status is associated with a higher risk of falling and fracture in elderly people living at home in France: the Three-City cohort study.

    Science.gov (United States)

    Torres, M J; Féart, C; Samieri, C; Dorigny, B; Luiking, Y; Berr, C; Barberger-Gateau, P; Letenneur, L

    2015-08-01

    Falling and fractures are a public health problem in elderly people. The aim of our study was to investigate whether nutritional status is associated with the risk of falling or fracture in community-dwelling elderly. Poor nutritional status was significantly associated with a higher risk of both falling and fractures. Nutrition could play a role to prevent falls and fractures. The purpose of this study is to investigate whether a poor nutritional status is associated with the risk of falling and of fracture in community dwelling elderly. Baseline nutritional status of participants was assessed using the Mini Nutritional Assessment (MNA). After a follow-up of 12 years, 6040 individuals with available data for falls and 6839 for fracture were included. People who presented the outcomes at baseline were excluded. Cox models were used to evaluate the associations between nutritional status and the risks of fall or fracture. The frequency of poor nutritional status (MNA ≤ 23.5), at baseline, was respectively 12.0% in the "fall study sample" and 12.8% in the "fracture study sample." Incident fall and fracture over 12 years were reported in 55.8 and 18.5% of the respective samples, respectively. In multivariate models controlled for sociodemographic data and several baseline health indicators, poor nutritional status was significantly associated with a higher risk of falling (hazard ratio (HR) = 1.66, 95% confidence interval (95% CI) 1.35-2.04 in men and HR = 1.20, 95% CI 1.07-1.34 in women) and with a higher risk of fracture (HR = 1.28, 95% CI 1.09-1.49). Poor nutritional status was associated with a higher risk of both falling and fractures in French elderly community-dwellers. Early screening and management of the nutritional status may be useful to reduce the frequency of these events in older people.

  11. Plastic fracture mechanics prediction of fracture instability in a circumferentially cracked pipe in bending--1. J-integral analysis

    International Nuclear Information System (INIS)

    Zahoor, A.; Kanninen, M.F.

    1980-01-01

    A method of evaluating the J-integral for a circumferentially cracked pipe in bending is proposed. The method allows a J-resistance curve to be evaluated directly from the load-displacement record obtained in a pipe fracture experiment. This method also permits an analysis for fracture instability in a circumferential crack growth using a J-resistance curve and the tearing modulus parameter. The importance of using a J-resistance curve that is consistent with the type of constraint for a given application is emphasized. 18 refs

  12. Mixed-mode fracture of ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Petrovic, J.J.

    1985-01-01

    The mixed-mode fracture behavior of ceramic materials is of importance for monolithic ceramics in order to predict the onset of fracture under generalized loading conditions and for ceramic composites to describe crack deflection toughening mechanisms. Experimental data on surface flaw mixed-mode fracture in various ceramics indicate that the flaw-plane normal stress at fracture decreases with increasing in-flaw-plane shear stress, although present data exhibit a fairly wide range in details of this sigma - tau relationship. Fracture from large cracks suggests that Mode II has a greater effect on Mode I fracture than Mode III. A comparison of surface flaw and large crack mixed-mode I-II fracture responses indicated that surface flaw behavior is influenced by shear resistance effects.

  13. Diamond-like carbon coatings enhance scratch resistance of bearing surfaces for use in joint arthroplasty: hard substrates outperform soft.

    Science.gov (United States)

    Roy, Marcel E; Whiteside, Leo A; Katerberg, Brian J

    2009-05-01

    The purpose of this study was to test the hypotheses that diamond-like carbon (DLC) coatings will enhance the scratch resistance of a bearing surface in joint arthroplasty, and that a hard ceramic substrate will further enhance scratch resistance by reducing plastic deformation. We tested these hypotheses by applying a hard DLC coating to medical-grade cobalt chromium alloy (CoCr) and magnesia-stabilized zirconia (Mg-PSZ) femoral heads and performing scratch tests to determine the loads required to cause cohesive and adhesive fracture of the coating. Scratch tracks of DLC-coated and noncoated heads were then scanned by optical profilometry to determine scratch depth, width, and pile-up (raised edges), as measures of susceptibility to scratching. DLC-coated CoCr specimens exhibited cohesive coating fracture as wedge spallation at an average load of 9.74 N, whereas DLC-coated Mg-PSZ exhibited cohesive fracture as arc-tensile cracks and chipping at a significantly higher average load of 41.3 N (p coating fracture, DLC-CoCr delaminated at an average load of 35.2 N, whereas DLC-Mg-PSZ fractured by recovery spallation at a significantly higher average load of 46.8 N (p DLC-CoCr and DLC-Mg-PSZ specimens exhibited significantly shallower scratches and less pile-up than did uncoated specimens (p DLC-Mg-PSZ better resisted plastic deformation, requiring significantly higher loads for cohesive and adhesive coating fracture. These findings supported both of our hypotheses. (c) 2008 Wiley Periodicals, Inc.

  14. Short uncemented stems allow greater femoral flexibility and may reduce peri-prosthetic fracture risk: a dry bone and cadaveric study.

    Science.gov (United States)

    Jones, Christopher; Aqil, Adeel; Clarke, Susannah; Cobb, Justin P

    2015-09-01

    Short femoral stems for uncemented total hip arthroplasty have been introduced as a safe alternative to traditional longer stem designs. However, there has been little biomechanical examination of the effects of stem length on complications of surgery. This study aims to examine the effect of femoral stem length on torsional resistance to peri-prosthetic fracture. We tested 16 synthetic and two paired cadaveric femora. Specimens were implanted and then rapidly rotated until fracture to simulate internal rotation on a planted foot, as might occur during stumbling. 3D planning software and custom-printed 3D cutting guides were used to enhance the accuracy and consistency of our stem insertion technique. Synthetic femora implanted with short stems fractured at a significantly higher torque (27.1 vs. 24.2 Nm, p = 0.03) and angle (30.3° vs. 22.3°, p = 0.002) than those implanted with long stems. Fracture patterns of the two groups were different, but showed remarkable consistency within each group. These characteristic fracture patterns were closely replicated in the pair of cadaveric femora. This new short-stemmed press-fit femoral component allows more femoral flexibility and confers a higher resistance to peri-prosthetic fracture from torsional forces than long stems.

  15. Plantar impact causing midfoot fractures result in higher forces in Chopart's joint than in the ankle joint.

    Science.gov (United States)

    Richter, M; Wippermann, B; Thermann, H; Schroeder, G; Otte, D; Troeger, H D; Krettek, C

    2002-03-01

    Force effect (impact, extent of foot compartment deformation) and result (fracture pattern) for midfoot fractures in car occupants is known. An analysis of the processes in the foot was intended to improve car safety. Eleven fresh, unfrozen, unpreserved intact human cadavers (age: 36.8 (16-61) years, gender: male, race: Caucasian) were studied 24-72 h after death. In 3 cadavers (5 feet) the experimental design was established: entire cadaver fixed on a special tray in supine position, pendulum with bar impactor hitting the foot plantar to Lisfranc's joint. A custom-made pressure sensor was inserted in the ankle (A), talonavicular (TN) and calcaneocuboid (CC) joints (resolution: 1 cm2, sampling rate: 500/s). Sixteen feet were measured: midfoot fractures were induced in 11 feet. The maximum pressure amounted to 1.22-2.55 MPa (2.04+/-0.412) at 0.005 0.195 s (0.067+/-0.059) after impact. The maximum pressure occurred in 8 (50%) cases in the ankle, in 7 (44%) of the TN and 1 (6%) of the CC joints. A comparison of the first 200 pressure samples after impact of all sensor fields resulted in higher forces in Chopart's joint than in the ankle (t-test: p < 0.001). These force differences were higher in cases with midfoot fractures (mixed model analysis of variance: p = 0.003). Due to considerable forces in Chopart's joint we recommend a modification of the actual crash test dummy lower extremity model with an additional load cell that detects forces in the longitudinal direction of the foot axis.

  16. Relative Permeability of Fractured Rock

    Energy Technology Data Exchange (ETDEWEB)

    Mark D. Habana

    2002-06-30

    Contemporary understanding of multiphase flow through fractures is limited. Different studies using synthetic fractures and various fluids have yielded different relative permeability-saturation relations. This study aimed to extend the understanding of multiphase flow by conducting nitrogen-water relative permeability experiments on a naturally-fractured rock from The Geysers geothermal field. The steady-state approach was used. However, steady state was achieved only at the endpoint saturations. Several difficulties were encountered that are attributed to phase interference and changes in fracture aperture and surface roughness, along with fracture propagation/initiation. Absolute permeabilities were determined using nitrogen and water. The permeability values obtained change with the number of load cycles. Determining the absolute permeability of a core is especially important in a fractured rock. The rock may change as asperities are destroyed and fractures propagate or st rain harden as the net stresses vary. Pressure spikes occurred in water a solute permeability experiments. Conceptual models of an elastic fracture network can explain the pressure spike behavior. At the endpoint saturations the water relative permeabilities obtained are much less than the nitrogen gas relative permeabilities. Saturations were determined by weighing and by resistivity calculations. The resistivity-saturation relationship developed for the core gave saturation values that differ by 5% from the value determined by weighing. Further work is required to complete the relative permeability curve. The steady-state experimental approach encountered difficulties due to phase interference and fracture change. Steady state may not be reached until an impractical length of time. Thus, unsteady-state methods should be pursued. In unsteady-state experiments the challenge will be in quantifying rock fracture change in addition to fluid flow changes.

  17. Determination of the resistance to tensile fracture of refractory mixtures of gunite

    International Nuclear Information System (INIS)

    Gomez Sanchez, A; Tomba Martinez, A.G

    2004-01-01

    The determination of the mechanical properties of cooled refractory mixtures is useful since it allows the materials to be compared for the purposes of selection and reports on their degree of internal cohesion, green or calcination, so that their structural ability can be estimated, especially during installation. Given the testing difficulties originating in the fragility of the ceramic materials, the tension test is not generally used in refractories. However, ASTM C-307 94 determines the tensile strength of cured chemical-resistant materials, for which this work considered the possibility of testing cement-based monolithic refractories in this non conventional condition. The tensile resistance to the fracture of three different refractory mixtures (A, B 1 and B 2 ), used in heat repairing by gunite in coking ovens, that were characterized by chemical, granulometric, and mineralogical analysis pycnometric density measurements. The pieces for the tests ('bone' type: length = 75 mm, maximum width = 40 mm, minimum width = 25 mm, thickness = 10 - 25 mm) were prepared by ramming of mixtures of material/water in a metallic mold; they were sinterized (1200 o C, 1h) and characterized by measures of bulk density, porosity and observation of the surface texture, in green and calcinated. The tensile tests, based on ASTM C-307 94, were performed in an Instron model 4467 machine in open air, at room temperature and position control (0.5 mm/min). The following values were obtained, in kPa: AW347±308; B 1 W738±130; B 2 W604±64. These values were lower than those for the tensile fracture module (MOR), although they displayed an equivalent order: A≤B 2 ≤B 1 . This was related to the characteristics of each refractory mixture and at the end of the pieces tested (CW)

  18. Determining the fracture resistance of fibre-reinforced glass matrix composites by means of the chevron-notch flexural technique

    Czech Academy of Sciences Publication Activity Database

    Boccaccini, A. R.; Kern, H.; Dlouhý, Ivo

    2001-01-01

    Roč. 308, 1/2 (2001), s. 111-117 ISSN 0921-5093 R&D Projects: GA ČR GV101/96/K264 Institutional research plan: CEZ:AV0Z2041904 Keywords : glass matrix composites * fracture toughness * chevron notch test Subject RIV: JH - Ceramics, Fire-Resistant Materials and Glass Impact factor: 0.978, year: 2001

  19. Loading rate and test temperature effects on fracture of in situ niobium silicide-niobium composites

    International Nuclear Information System (INIS)

    Rigney, J.D.; Lewandowski, J.J.

    1996-01-01

    Arc cast, extruded, and heat-treated in situ composites of niobium silicide (Nb 5 Si 3 ) intermetallic with niobium phases (primary--Nb p and secondary--Nb s ) exhibited high fracture resistance in comparison to monolithic Nb 5 Si 3 . In toughness tests conducted at 298 K and slow applied loading rates, the fracture process proceeded by the microcracking of the Nb 5 Si 3 and plastic deformation of the Nb p and Nb s phases, producing resistance-curve behavior and toughnesses of 28 MPa√m with damage zone lengths less than 500 microm. The effects of changes in the Nb p yield strength and fracture behavior on the measured toughnesses were investigated by varying the loading rates during fracture tests at both 77 and 298 K. Quantitative fractography was utilized to completely characterize each fracture surface created at 298 K in order to determine the type of fracture mode (i.e., dimpled, cleavage) exhibited by the Nb p . Specimens tested at either higher loading rates or lower test temperatures consistently exhibited a greater amount of cleavage fracture in the Nb p , while the Nb s always remained ductile. However, the fracture toughness values determined from experiments spanning six orders of magnitude in loading rate at 298 and 77 K exhibited little variation, even under conditions when the majority of Nb p phases failed by cleavage at 77 K. The changes in fracture mode with increasing loading rate and/or decreasing test temperature and their effects on fracture toughness are rationalized by comparison to existing theoretical models

  20. Fracture, aging and disease in bone

    Energy Technology Data Exchange (ETDEWEB)

    Ager, J.W.; Balooch, G.; Ritchie, R.O.

    2006-02-01

    From a public health perspective, developing a detailed mechanistic understanding of the well-known increase in fracture risk of human bone with age is essential. This also represents a challenge from materials science and fracture mechanics viewpoints. Bone has a complex, hierarchical structure with characteristic features ranging from nanometer to macroscopic dimensions; it is therefore significantly more complex than most engineering materials. Nevertheless, by examining the micro-/nano-structural changes accompanying the process of aging using appropriate multiscale experimental methods and relating them to fracture mechanics data, it is possible to obtain a quantitative picture of how bone resists fracture. As human cortical bone exhibits rising ex vivo crack-growth resistance with crack extension, its fracture toughness must be evaluated in terms of resistance-curve (R-curve) behavior. While the crack initiation toughness declines with age, the more striking finding is that the crack-growth toughness declines even more significantly and is essentially absent in bone from donors exceeding 85 years in age. To explain such an age-induced deterioration in the toughness of bone, we evaluate its fracture properties at multiple length scales, specifically at the molecular and nanodimensions using pico-force atomic-force microscopy, nanoindentation and vibrational spectroscopies, at the microscale using electron microscopy and hard/soft x-ray computed tomography, and at the macroscale using R-curve measurements. We show that the reduction in crack-growth toughness is associated primarily with a degradation in the degree of extrinsic toughening, in particular involving crack bridging, and that this occurs at relatively coarse size-scales in the range of tens to hundreds of micrometers. Finally, we briefly describe how specific clinical treatments, e.g., with steroid hormones to treat various inflammatory conditions, can prematurely damage bone, thereby reducing its

  1. Fracture propagation in gas pipelines - relevance to submarine lines

    Energy Technology Data Exchange (ETDEWEB)

    Fearnehough, G D [British Gas Corp., Newcastle upon Tyne. Engineering Research Station

    1976-09-01

    This paper reviews the factors which control fracture propagation in pipes and suggests how they are influenced by submarine environments. If fracture arrest capability is required then these factors should be considered in terms of the design philosophy and the maximum tolerable length of fracture which can be repaired. The paper shows that brittle fracture characteristics of submarine pipelines are probably similar to land based lines and fracture arrest can only be guaranteed by appropriate material toughness specification. Resistance to ductile fracture propagation in submarine lines is enhanced by lower design stresses, thicker pipe, concrete coating and the effect of hydrostatic head on gas dynamics. However, additional factors due to submarine design can be deleterious viz: uncertainty about backfill integrity and a tendency of thicker steels to low fracture resistance arising from 'separation' formation. Attention is drawn to problems which may arise with transportation of gases rich in hydrocarbons and the use of mechanical methods of fracture arrest.

  2. Study on fracture and stress corrosion cracking behavior of casing sour service materials

    International Nuclear Information System (INIS)

    Sequera, C.; Gordon, H.

    2003-01-01

    Present work describes sulphide stress corrosion cracking and fracture toughness tests performed to high strength sour service materials of T-95, C-100 and C-110 oil well tubular grades. P-110 was considered as a reference case, since it is one of the high strength materials included in specification 5CT of American Petroleum Institute, API. Sulphide stress corrosion cracking, impact and fracture toughness values obtained in the tests show that there is a correspondence among them. A decreasing classification order was established, namely C-100, T-95, C-110 and P-110. Special grades steels studied demonstrated a better behavior in the evaluated properties than the reference case material grade: P-110. Results obtained indicate that a higher sulphide stress corrosion cracking resistance is related to a higher toughness. The fracture toughness results evidence the hydrogen influence on reducing the toughness values. (author)

  3. Fracture toughness of dentin/resin-composite adhesive interfaces.

    Science.gov (United States)

    Tam, L E; Pilliar, R M

    1993-05-01

    The reliability and validity of tensile and shear bond strength determinations of dentin-bonded interfaces have been questioned. The fracture toughness value (KIC) reflects the ability of a material to resist crack initiation and unstable propagation. When applied to an adhesive interface, it should account for both interfacial bond strength and inherent defects at or near the interface, and should therefore be more appropriate for characterization of interface fracture resistance. This study introduced a fracture toughness test for the assessment of dentin/resin-composite bonded interfaces. The miniature short-rod specimen geometry was used for fracture toughness testing. Each specimen contained a tooth slice, sectioned from a bovine incisor, to form the bonded interface. The fracture toughness of an enamel-bonded interface was assessed in addition to the dentin-bonded interfaces. Tensile bond strength specimens were also prepared from the dentin surfaces of the cut bovine incisors. A minimum of ten specimens was fabricated for each group of materials tested. After the specimens were aged for 24 h in distilled water at 37 degrees C, the specimens were loaded to failure in an Instron universal testing machine. There were significant differences (p adhesives tested. Generally, both the fracture toughness and tensile bond strength measurements were highest for AllBond 2, intermediate for 3M MultiPurpose, and lowest for Scotchbond 2. Scanning electron microscopy of the fractured specimen halves confirmed that crack propagation occurred along the bond interface during the fracture toughness test. It was therefore concluded that the mini-short-rod fracture toughness test provided a valid method for characterization of the fracture resistance of the dentin-resin composite interface.

  4. Cyclic fatigue resistance of R-Pilot, WaveOne Gold Glider, and ProGlider glide path instruments.

    Science.gov (United States)

    Keskin, Cangül; İnan, Uğur; Demiral, Murat; Keleş, Ali

    2018-02-17

    The aim of the present study was to compare the cyclic fatigue resistance of R-Pilot (VDW; Munich, Germany) with ProGlider (Denstply Sirona; Ballaigues, Switzerland) and WaveOne Gold Glider (Denstply Sirona; Ballaigues, Switzerland) glide path instruments. R-Pilot, ProGlider, and WaveOne Gold Glider instruments were collected (n = 15) and tested in a dynamic cyclic fatigue test device, which has an artificial canal with 60° angle of curvature and a 5-mm radius of curvature. All instruments were operated until fracture occurred, and both time to fracture (TF) and the lengths of the fractured fragments were recorded. Mean and standard deviations of TF and fragment length were calculated for each reciprocating system. TF data and fractured fragment length data were subjected to one-way ANOVA and post-hoc Tukey tests (P  0.05). Weibull analysis revealed that WaveOne Gold Glider showed the highest predicted TF value for 99% survival rate, which was followed by R-Pilot and ProGlider. Regarding the length of the fractured tips, there were no significant differences among the instruments (P > 0.05). The reciprocating WaveOne Gold Glider and R-Pilot instruments had significantly higher cyclic fatigue resistance than rotary ProGlider instruments. This study reported that novel reciprocating glide path instruments exhibited higher cyclic fatigue resistance than rotating glide path instrument.

  5. J-resistance curves for Inconel 690 and Incoloy 800 nuclear steam generators tubes at room temperature and at 300 °C

    Energy Technology Data Exchange (ETDEWEB)

    Bergant, Marcos A., E-mail: marcos.bergant@cab.cnea.gov.ar [Gerencia CAREM, Centro Atómico Bariloche (CNEA), Av. Bustillo 9500, San Carlos de Bariloche 8400 (Argentina); Yawny, Alejandro A., E-mail: yawny@cab.cnea.gov.ar [División Física de Metales, Centro Atómico Bariloche (CNEA) / CONICET, Av. Bustillo 9500, San Carlos de Bariloche 8400 (Argentina); Perez Ipiña, Juan E., E-mail: juan.perezipina@fain.uncoma.edu.ar [Grupo Mecánica de Fractura, Universidad Nacional del Comahue / CONICET, Buenos Aires 1400, Neuquén 8300 (Argentina)

    2017-04-01

    The structural integrity of steam generator tubes is a relevant issue concerning nuclear plant safety. In the present work, J-resistance curves of Inconel 690 and Incoloy 800 nuclear steam generator tubes with circumferential and longitudinal through wall cracks were obtained at room temperature and 300 °C using recently developed non-standard specimens' geometries. It was found that Incoloy 800 tubes exhibited higher J-resistance curves than Inconel 690 for both crack orientations. For both materials, circumferential cracks resulted into higher fracture resistance than longitudinal cracks, indicating a certain degree of texture anisotropy introduced by the tube fabrication process. From a practical point of view, temperature effects have found to be negligible in all cases. The results obtained in the present work provide a general framework for further application to structural integrity assessments of cracked tubes in a variety of nuclear steam generator designs. - Highlights: •Non-standard fracture specimens were obtained from nuclear steam generator tubes. •Specimens with circumferential and longitudinal through-wall cracks were used. •Inconel 690 and Incoloy 800 steam generator tubes were tested at 24 and 300 °C. •Fracture toughness for circumferential cracks was higher than for longitudinal cracks. •Incoloy 800 showed higher fracture toughness than Inconel 690 steam generator tubes.

  6. Experimental comparative study and fracture resistance simulation with irrigation solution of 0.2% chitosan, 2.5% NaOCl and 17% EDTA

    Directory of Open Access Journals (Sweden)

    Ernani Ernani

    2015-09-01

    Full Text Available Background: Preparation in endodontic need irrigation materials as root canal debridement and disinfectant. However, irrigation materials is one of the factors that influence the tendency of fracture. Purpose: This study was aimed to see the resistance and fracture distribution if teeth irrigated with high molecular horseshoe crab chitosan at 0.2% concentration, 2.5% NaOCl solution and 17% EDTA solution in endodontic treatment with finite element method (FEM simulation study and experimental studies. Method: Endodontic treatment performed on 28 maxillary premolars with group A: irrigation solution of 17% EDTA and 2.5% NaOCl solution; group B: 2.5% NaOCl irrigation solution; group C: 2.5% NaOCl irrigation solution and 0.2% chitosan solution; group D: 0.2% chitosan solution irrigation. Final restoration was done using prefabricated glass fiber post. Cementation of post using resin cement then restored with direct composite resin restorations. Pressure test was performed with a Universal Testing Machine with a speed of 0.5 mm/min until fracture occurred. A three dimensional finite element analysis was performed for total deformation, equivalent (von-mises stress, and equivalent elastic strains. Result: Anova test showed significant differences in fracture resistance (p0.05. Statistical analysis showed no significant difference (p>0.05 between the results of experiment and FEM analysis results using the t-test. Conclusion: The results of this study demonstrated that there was effect of the use of high molecular 0.2% chitosan as a combined irrigation with NaOCl, but did not affect the fracture pattern distribution of endodontically treated teeth both experimentally and FEM analysis test.

  7. Outcome of nonunion fractures in dogs treated with fixation, compression resistant matrix, and recombinant human bone morphogenetic protein-2.

    Science.gov (United States)

    Massie, Anna M; Kapatkin, Amy S; Fuller, Mark C; Verstraete, Frank J M; Arzi, Boaz

    2017-03-20

    To report the use of compression resistant matrix (CRM) infused with recombinant human bone morphogenetic protein (rhBMP-2) prospectively in the healing of nonunion long-bone fractures in dogs. A longitudinal cohort of dogs that were presented with nonunion fractures were classified and treated with CRM soaked with rhBMP-2 and fracture fixation. They were followed with serial radiographs and evaluated for healing times and complications according to the time frame and definitions previously established for orthopaedic clinical cases. Eleven nonunion fractures in nine dogs were included. Median healing time was 10 weeks (range: 7-20 weeks). Major perioperative complications due to bandage morbidity were encountered in two of 11 limbs and resolved. All other complications were minor. They occurred perioperatively in eight of 11 limbs. Minor follow-up complications included short-term in one of two limbs, mid-term in one of three, and long-term in four of five limbs. Nine limbs returned to full function and two limbs returned to acceptable function at the last follow-up. Nonunion fractures given a poor prognosis via standard-of-care treatment were successfully repaired using CRM with rhBMP-2 accompanying fixation. These dogs, previously at high risk of failure, returned to full or acceptable function.

  8. A herbicide-resistant ACCase 1781 Setaria mutant shows higher fitness than wild type.

    Science.gov (United States)

    Wang, T; Picard, J C; Tian, X; Darmency, H

    2010-10-01

    It is often alleged that mutations conferring herbicide resistance have a negative impact on plant fitness. A mutant ACCase1781 allele endowing resistance to the sethoxydim herbicide was introgressed from a resistant green foxtail (Setaria viridis (L.) Beauv) population into foxtail millet (S. italica (L.) Beauv.). (1) Better and earlier growth of resistant plants was observed in a greenhouse cabinet. (2) Resistant plants of the advanced BC7 backcross generation showed more vigorous juvenile growth in the field, earlier flowering, more tillers and higher numbers of grains than susceptible plants did, especially when both genotypes were grown in mixture, but their seeds were lighter than susceptible seeds. (3) Field populations originating from segregating hybrids had the expected allele frequencies under normal growth conditions, but showed a genotype shift toward an excess of homozygous resistant plants within 3 years in stressful conditions. Lower seed size, lower germination rate and perhaps unexplored differences in seed longevity and predation could explain how the resistant plants have the same field fitness over the whole life cycle as the susceptible ones although they produce more seeds. More rapid growth kinetics probably accounted for higher fitness of the resistant plants in adverse conditions. The likelihood of a linkage with a beneficial gene is discussed versus the hypothesis of a pleiotropic effect of the ACCase resistance allele. It is suggested that autogamous species like Setaria could not develop a resistant population without the help of a linkage with a gene producing a higher fitness.

  9. Fracture Behavior and Properties of Functionally Graded Fiber-Reinforced Concrete

    International Nuclear Information System (INIS)

    Roesler, Jeffery; Bordelon, Amanda; Gaedicke, Cristian; Park, Kyoungsoo; Paulino, Glaucio

    2008-01-01

    In concrete pavements, a single concrete mixture design is selected to resist mechanical loading without attempting to adversely affect the concrete pavement shrinkage, ride quality, or noise attenuation. An alternative approach is to design distinct layers within the concrete pavement surface which have specific functions thus achieving higher performance at a lower cost. The objective of this research was to address the structural benefits of functionally graded concrete materials (FGCM) for rigid pavements by testing and modeling the fracture behavior of different combinations of layered plain and synthetic fiber-reinforced concrete materials. Fracture parameters and the post-peak softening behavior were obtained for each FGCM beam configuration by the three point bending beam test. The peak loads and initial fracture energy between the plain, fiber-reinforced, and FGCM signified similar crack initiation. The total fracture energy indicated improvements in fracture behavior of FGCM relative to full-depth plain concrete. The fracture behavior of FGCM depended on the position of the fiber-reinforced layer relative to the starter notch. The fracture parameters of both fiber-reinforced and plain concrete were embedded into a finite element-based cohesive zone model. The model successfully captured the experimental behavior of the FGCMs and predicted the fracture behavior of proposed FGCM configurations and structures. This integrated approach (testing and modeling) demonstrates the viability of FGCM for designing layered concrete pavements system

  10. Aging and Fracture of Human Cortical Bone and Tooth Dentin

    Energy Technology Data Exchange (ETDEWEB)

    Ager, Joel; Koester, Kurt J.; Ager III, Joel W.; Ritchie, Robert O.

    2008-05-07

    Mineralized tissues, such as bone and tooth dentin, serve as structural materials in the human body and, as such, have evolved to resist fracture. In assessing their quantitative fracture resistance or toughness, it is important to distinguish between intrinsic toughening mechanisms which function ahead of the crack tip, such as plasticity in metals, and extrinsic mechanisms which function primarily behind the tip, such as crack bridging in ceramics. Bone and dentin derive their resistance to fracture principally from extrinsic toughening mechanisms which have their origins in the hierarchical microstructure of these mineralized tissues. Experimentally, quantification of these toughening mechanisms requires a crack-growth resistance approach, which can be achieved by measuring the crack-driving force, e.g., the stress intensity, as a function of crack extension ("R-curve approach"). Here this methodology is used to study of the effect of aging on the fracture properties of human cortical bone and human dentin in order to discern the microstructural origins of toughness in these materials.

  11. Influence of perforation erosion on multiple growing hydraulic fractures in multi-stage fracturing

    Directory of Open Access Journals (Sweden)

    Yongming Li

    2018-02-01

    Full Text Available In multi-stage hydraulic fracturing, the limited-entry method is widely used to promote uniform growth of multiple fractures. However, this method's effectiveness may be lost because the perforations will be eroded gradually during the fracturing period. In order to study the influence of perforation erosion on multiple growing hydraulic fractures, we combined the solid–fluid coupled model of hydraulic fracture growth with an empirical model of perforation erosion to implement numerical simulation. The simulations show clearly that the erosion of perforation will significantly deteriorate the non-uniform growth of multiple fractures. Based on the numerical model, we also studied the influences of proppant concentration and injection rates on perforation erosion in multi-stage hydraulic fracturing. The results indicate that the initial erosion rates become higher with the rising proppant concentration, but the growth of multiple hydraulic fractures is not sensitive to the varied proppant concentration. In addition, higher injection rates are beneficial significantly to the limited-entry design, leading to more uniform growth of fractures. Thus, in multi-stage hydraulic fracturing enough high injection rates are proposed to keep uniform growths. Keywords: Unconventional oil and gas reservoir, Horizontal well, Perforation friction, Perforation erosion, Multi-stage hydraulic fracturing, Numerical simulation, Mathematic model, Uniform growth of fractures

  12. Geophysical signatures of a fracture controlled U-mineralisation: a case study from Mulapalle area, Cuddapah district, Andhra Pradesh

    International Nuclear Information System (INIS)

    Rao, R.L.N.; Sethuram, S.; Rao, B.N.; Tiku, K.L.; Ram, Subhash

    2000-01-01

    Geophysical methods have been extensively used for delineation of structural features such as fractures and shear zones which often control and host economic mineralisation. Numerous fractures hosting uranium mineralisation and confined to younger intrusives and leucogranites occur within basement gneissic complex on the southwestern margin of the Mesoproterozoic Cuddapah basin. The geophysical signatures of one such mineralised fracture zone near Mulapalle are discussed. Mineralised fractures are mostly confined to a zone of cataclastic rocks characterised by widely varying magnetic character with respect to the surroundings. A strong redox barrier associated with the mineralisation is revealed by self-potential data. The mineralised zone is also indicated by a higher order resistivity attributable to the enrichment of silica in the fracture zone. (author)

  13. Development of carbon steel with superior resistance to wall thinning and fracture for nuclear piping system

    International Nuclear Information System (INIS)

    Rhee, Chang Kyu; Lee, Min Ku; Park, Jin Ju

    2010-07-01

    Carbon steel is usually used for piping for secondary coolant system in nuclear power plant because of low cost and good machinability. However, it is generally reported that carbon steel was failed catastrophically because of its low resistance to wall thinning and fracture toughness. Especially, flow accelerated corrosion (FAC) is one of main problems of the wall thinning of piping in the nuclear power plant. Therefore, in this project, fabrication technology of new advanced carbon steel materials modified by dispersion of nano-carbide ceramics into the matrix is developed first in order to improve the resistance to wall thinning and fracture toughness drastically compared to the conventional one. In order to get highly wettable fine TiC ceramic particles into molten metal, the micro-sized TiC particles were first mechanically milled by Fe (MMed TiC/Fe) in a high energy ball mill machine in Ar gas atmosphere, and then mixed with surfactant metal elements (Sn, Cr, Ni) to obtain better wettability, as this lowered surface tension of the carbon steel melt. According to microscopic images revealed that an addition of MMed TiC/Fe-surfactant mixed powders favorably disperses the fine TiC particles in the carbon steel matrix. It was also found that the grain size refinement of the cast matrix is achieved remarkably when fine TiC particles were added due to the fact that they act as nucleation sites during the solidification process. As a results, a cast carbon steel dispersed with fine TiC particles shows improved mechanical properties such as hardness, tensile strength and cavitation resistance compared to that of without particles. However, the slight decrease of toughness was found

  14. Development plates for stable internal fixation: Study of mechanical resistance in simulated fractures of the mandibular condyle.

    Science.gov (United States)

    Celegatti Filho, Tóride Sebastião; Rodrigues, Danillo Costa; Lauria, Andrezza; Moreira, Roger William Fernandes; Consani, Simonides

    2015-01-01

    To develop Y-shaped plates with different thicknesses to be used in simulated fractures of the mandibular condyle. Ten plates were developed in Y shape, containing eight holes, and 30 synthetic polyurethane mandible replicas were developed for the study. The load test was performed on an Instron Model 4411 universal testing machine, applying load in the mediolateral and anterior-posterior positions on the head of the condyle. Two-way ANOVA with Tukey testing with a 5% significance level was used. It was observed that when the load was applied in the medial-lateral plate of greater thickness (1.5 mm), it gave the highest strength, while in the anteroposterior direction, the plate with the highest resistance was of the lesser thickness (0.6 mm). A plate with a thickness of 1.5 mm was the one with the highest average value for all displacements. In the anteroposterior direction, the highest values of resistance were seen in the displacement of 15 mm. After comparing the values of the biomechanical testing found in the scientific literature, it is suggested that the use of Y plates are suitable for use in subcondylar fractures within the limitations of the study. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Development of bushing material with higher corrosion and wear resistance; Taishoku taimamosei dogokin bush zairyo no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Kira, T; Yokota, H; Kamiya, S [Taiho Kogyo Co. Ltd., Osaka (Japan)

    1997-10-01

    Recent diesel engines require a higher performance and a longer life. Due to higher cylinder pressure, the operating load and temperature of piston pin bushings become higher. Therefore, higher load capacity, higher wear resistance and higher corrosion resistance are required for piston pin bushings. For this reason, we have studied the effect of components added to copper alloy upon the corrosion resistance and the effect of hard particles dispersed in copper matrix upon the wear resistance and the influence of hard particles on the machinablity of materials. Based on the experimental results, we have developed a new bushing material improving wear and corrosion resistance. 17 figs., 3 tabs.

  16. Cyclic Strain Resistance, Stress Response, Fatigue Life, and Fracture Behavior of High Strength Low Alloy Steel 300 M

    Science.gov (United States)

    Manigandan, K.; Srivatsan, T. S.; Tammana, Deepthi; Poorgangi, Behrang; Vasudevan, Vijay K.

    2014-05-01

    The focus of this technical manuscript is a record of the specific role of microstructure and test specimen orientation on cyclic stress response, cyclic strain resistance, and cyclic stress versus strain response, deformation and fracture behavior of alloy steel 300 M. The cyclic strain amplitude-controlled fatigue properties of this ultra-high strength alloy steel revealed a linear trend for the variation of log elastic strain amplitude with log reversals-to-failure, and log plastic strain amplitude with log reversals-to-failure for both longitudinal and transverse orientations. Test specimens of the longitudinal orientation showed only a marginal improvement over the transverse orientation at equivalent values of plastic strain amplitude. Cyclic stress response revealed a combination of initial hardening for the first few cycles followed by gradual softening for a large portion of fatigue life before culminating in rapid softening prior to catastrophic failure by fracture. Fracture characteristics of test specimens of this alloy steel were different at both the macroscopic and fine microscopic levels over the entire range of cyclic strain amplitudes examined. Both macroscopic and fine microscopic observations revealed fracture to be a combination of both brittle and ductile mechanisms. The underlying mechanisms governing stress response, deformation characteristics, fatigue life, and final fracture behavior are presented and discussed in light of the competing and mutually interactive influences of test specimen orientation, intrinsic microstructural effects, deformation characteristics of the microstructural constituents, cyclic strain amplitude, and response stress.

  17. Effect of different composite core materials on fracture resistance of endodontically treated teeth restored with FRC posts

    OpenAIRE

    PANITIWAT, Prapaporn; SALIMEE, Prarom

    2017-01-01

    Abstract Objective This study evaluated the fracture resistance of endodontically treated teeth restored with fiber reinforced composite posts, using three resin composite core build-up materials, (Clearfil Photo Core (CPC), MultiCore Flow (MCF), and LuxaCore Z-Dual (LCZ)), and a nanohybrid composite, (Tetric N-Ceram (TNC)). Material and Methods Forty endodontically treated lower first premolars were restored with quartz fiber posts (D.T. Light-Post) cemented with resin cement (Panavia F2...

  18. Influence of root embedment material and periodontal ligament simulation on fracture resistance tests Influência do material de inclusão e da simulação do ligamento periodontal nos ensaios de resistência à fratura

    Directory of Open Access Journals (Sweden)

    Carlos José Soares

    2005-03-01

    Full Text Available The aim of this study was to evaluate the influence of the embedment material and periodontal ligament simulation on fracture resistance of bovine teeth. Eighty bovine incisor teeth were randomized into 8 groups (n = 10, embedded in acrylic or polystyrene resin using 4 types of periodontal ligament simulation: 1 - absence of the ligament; 2 - polyether impression material; 3 - polysulfide impression material; 4 - polyurethane elastomeric material. The specimens were stored at 37°C and 100% humidity for 24 hours. Specimens were submitted to tangential load on the palatal surface at 0.5 mm/minute crosshead speed until fracture. The fracture modes were analyzed as follows: 1 - coronal fracture; 2 - cemento-enamel junction fracture; 3 - partial root fracture; 4 - total root fracture. Statistical analyses by two-way ANOVA and Tukey's test were applied (p O objetivo deste estudo foi avaliar a influência do material de inclusão e da simulação de ligamento periodontal na resistência à fratura de dentes bovinos. Oitenta incisivos bovinos foram divididos em 8 grupos (n = 10 e, então, incluídos em cilindros com dois materiais, resina acrílica ou resina de poliestireno, usando-se quatro tipos de simulação do ligamento periodontal: 1 - ausência do ligamento; 2 - material de moldagem à base de poliéter; 3 - material de moldagem à base de polissulfeto; e 4 - material elastomérico à base de poliuretano. As amostras foram armazenadas em 100% de umidade a 37°C por 24 horas e então submetidas a carregamento tangencial na superfície palatina com velocidade de 0,5 mm/minuto até a fratura. Os padrões de fratura foram analisados de acordo com: 1 - fraturas coronais; 2 - fratura da junção esmalte-cemento; 3 - fratura parcial da raiz; 4 - fratura radicular total. A análise estatística empregou análise de variância fatorial e teste de Tukey (p < 0,05. Os resultados mostram que o método de inclusão e a simulação do ligamento periodontal

  19. Tearing resistance of some co-polyester sheets

    International Nuclear Information System (INIS)

    Kim, Ho Sung; Karger-Kocsis, Jozsef

    2004-01-01

    A three-zone model consisting of initial, evolutionary and stabilised plastic zones for tearing resistance was proposed for polymer sheets. An analysis with the model, based on the essential work of fracture (EWF) approach, was demonstrated to be capable for predicting specific total work of fracture along the tear path across all the plastic zones although accuracy of specific essential work of fracture is subject to improvement. Photo-elastic images were used for identification of plastic deformation sizes and profiles. Fracture mode change during loading was described in relation with the three zones. Tearing fracture behaviour of extruded mono- and bi-layer sheets of different types of amorphous co-polyesters and different thicknesses was investigated. Thick material exhibited higher specific total work of tear fracture than thin mono-layer sheet in the case of amorphous polyethylene terephthalate (PET). This finding was explained in terms of plastic zone size formed along the tear path, i.e., thick material underwent larger plastic deformation than thin material. When PET and polyethylene terephthalate glycol (PETG) were laminated with each other, specific total work of fracture of the bi-layer sheets was not noticeably improved over that of the constituent materials

  20. Evolution of structure and mechanical properties of hard yet fracture resistant W-B-C coatings with varying C/W ratio

    Czech Academy of Sciences Publication Activity Database

    Alishahi, M.; Mirzaei, S.; Souček, P.; Zábranský, L.; Buršíková, V.; Stupavska, M.; Peřina, Vratislav; Balázsi, K.; Czigany, Z.; Vašina, P.

    2018-01-01

    Roč. 340, č. 4 (2018), s. 103-111 ISSN 0257-8972 R&D Projects: GA MŠk LM2015056 Institutional support: RVO:61389005 Keywords : magnetron sputtering * W-B-C * microstructure * hardness * fracture resistance Subject RIV: JK - Corrosion ; Surface Treatment of Materials OBOR OECD: Coating and films Impact factor: 2.589, year: 2016

  1. Insufficiency fracture after radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Dong Ryul; Huh, Seung Jae [Dept.of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2014-12-15

    Insufficiency fracture occurs when normal or physiological stress applied to weakened bone with demineralization and decreased elastic resistance. Recently, many studies reported the development of IF after radiation therapy (RT) in gynecological cancer, prostate cancer, anal cancer and rectal cancer. The RT-induced insufficiency fracture is a common complication during the follow-up using modern imaging studies. The clinical suspicion and knowledge the characteristic imaging patterns of insufficiency fracture is essential to differentiate it from metastatic bone lesions, because it sometimes cause severe pain, and it may be confused with bone metastasis.

  2. Fracture-toughness variations in Alloy 718

    International Nuclear Information System (INIS)

    Mills, W.J.; Blackburn, L.D.

    1983-04-01

    The effect of product-form variations within a single heat on the J Ic fracture toughness behavior of Alloy 718 was examined at 24, 427 and 538 degree C using the multiple-specimen J R -curve method. Three product forms (plate, round bar and upset forging) were tested in both the conventional and modified heat-treatment (CHT and MHT) conditions. In CHT material, the fracture toughness response was different for the three product forms -- plate having the highest toughness, bar the lowest. The MHT was found to improve the overall fracture resistance for each product form. In this condition, plate and forging had very similar toughness values, but J Ic levels for the bar were considerably lower. These results and WHC data previously reported for four other Alloy 718 heats were unalloyed statistically to establish minimum-expected J Ic values based on tolerance limits bracketing 90% of a total population at a 95% confidence level. Metallographic and fractographic examinations of the seven material lots were performed to relate key microstructural features and operative fracture mechanisms to macroscopic properties. Generally, coarse δ precipitates controlled fracture properties in CHT material by initiating secondary dimples that pre-empted growth of the primary dimples nucleated by broken carbide inclusions. The MHT dissolved the coarse δ particles and thereby suppressed secondary microvoid coalescence. This generally enhanced the fracture resistance of Alloy 718, except when alternate secondary fracture mechanism, such as channel fracture and dimple rupture at δ-phase remnants, prematurely interrupted primary microvoid growth. 25 refs., 12 figs., 12 tabs

  3. Tensile and fracture properties of primary heat transport system piping material

    International Nuclear Information System (INIS)

    Singh, P.K.; Chattopadhyay, J.; Kushwaha, H.S.

    1997-07-01

    The fracture mechanics calculations in leak-before-break analysis of nuclear piping system require material tensile data and fracture resistance properties in the form of J-R curve. There are large variations in fracture parameters due to variation in chemical composition and process used in making the steel components. Keeping this in view, a comprehensive program has been planned to generate the material data base for primary heat transport system piping using the specimens machined from actual pipes used in service. The material under study are SA333 Gr.6 (base as well as weld) and SA350 LF2 (base). Since the operating temperatures of 500 MWe Indian PHWR PHT system piping range from 260 degC to 304 degC the test temperature chosen are 28 degC, 200 degC, 250 degC and 300 degC. Tensile and compact tension specimens have been fabricated from actual pipe according to ASTM standard. Fracture toughness of base metal has been observed to be higher compared to weld metal in SA333 Gr.6 material for the temperature under consideration. Fracture toughness has been observed to be higher for LC orientation (notch in circumferential direction) compared to CL orientation (notch is in longitudinal direction) for the temperature range under study. Fracture toughness value decreases with increase in temperature for the materials under study. Finally, chemical analysis has been carried out to investigate the reason for high toughness of the material. It has been concluded that low percentage of carbon and nitrogen, low inclusion rating and fine grain size has enhanced the fracture toughness value

  4. Characterization of reservoir fractures using conventional geophysical logging

    Directory of Open Access Journals (Sweden)

    Paitoon Laongsakul

    2011-04-01

    Full Text Available In hydrocarbon exploration fractures play an important role as possible pathways for the hydrocarbon flow and bythis enhancing the overall formation’s permeability. Advanced logging methods for fracture analysis, like the boreholeacoustic televiewer and Formation Microscanner (FMS are available, but these are additional and expensive tools. However,open and with water or hydrocarbon filled fractures are also sensitive to electrical and other conventional logging methods.For this study conventional logging data (electric, seismic, etc were available plus additional fracture information from FMS.Taking into account the borehole environment the results show that the micro-spherically focused log indicates fractures byshowing low resistivity spikes opposite open fractures, and high resistivity spikes opposite sealed ones. Compressional andshear wave velocities are reduced when passing trough the fracture zone, which are assumed to be more or less perpendicularto borehole axis. The photoelectric absorption curve exhibit a very sharp peak in front of a fracture filled with bariteloaded mud cake. The density log shows low density spikes that are not seen by the neutron log, usually where fractures,large vugs, or caverns exist. Borehole breakouts can cause a similar effect on the logging response than fractures, but fracturesare often present when this occurs. The fracture index calculation by using threshold and input weight was calculatedand there was in general a good agreement with the fracture data from FMS especially in fracture zones, which mainlycontribute to the hydraulic system of the reservoir. Finally, the overall results from this study using one well are promising,however further research in the combination of different tools for fracture identification is recommended as well as the useof core for further validation.

  5. Kinetics and fracture resistance of lithiated silicon nanostructure pairs controlled by their mechanical interaction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seok Woo; /Stanford U., Geballe Lab.; Lee, Hyun-Wook; /Stanford U., Materials Sci. Dept.; Ryu, Ill; /Brown U.; Nix, William D.; /Stanford U., Materials Sci. Dept.; Gao, Huajian; /Brown U.; Cui, Yi; /Stanford U., Materials Sci. Dept. /SLAC

    2015-06-01

    Following an explosion of studies of silicon as a negative electrode for Li-ion batteries, the anomalous volumetric changes and fracture of lithiated single Si particles have attracted significant attention in various fields, including mechanics. However, in real batteries, lithiation occurs simultaneously in clusters of Si in a confined medium. Hence, understanding how the individual Si structures interact during lithiation in a closed space is necessary. Herein, we demonstrate physical/mechanical interactions of swelling Si structures during lithiation using well-defined Si nanopillar pairs. Ex situ SEM and in situ TEM studies reveal that compressive stresses change the reaction kinetics so that preferential lithiation occurs at free surfaces when the pillars are mechanically clamped. Such mechanical interactions enhance the fracture resistance of This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Division of Materials Sciences and Engineering, under Contract No. DE-AC02-76SF00515. SLAC-PUB-16300 2 lithiated Si by lessening the tensile stress concentrations in Si structures. This study will contribute to improved design of Si structures at the electrode level for high performance Li-ion batteries.

  6. Correlation of Hip Fracture with Other Fracture Types: Toward a Rational Composite Hip Fracture Endpoint

    Science.gov (United States)

    Colón-Emeric, Cathleen; Pieper, Carl F.; Grubber, Janet; Van Scoyoc, Lynn; Schnell, Merritt L; Van Houtven, Courtney Harold; Pearson, Megan; Lafleur, Joanne; Lyles, Kenneth W.; Adler, Robert A.

    2016-01-01

    Purpose With ethical requirements to the enrollment of lower risk subjects, osteoporosis trials are underpowered to detect reduction in hip fractures. Different skeletal sites have different levels of fracture risk and response to treatment. We sought to identify fracture sites which cluster with hip fracture at higher than expected frequency; if these sites respond to treatment similarly, then a composite fracture endpoint could provide a better estimate of hip fracture reduction. Methods Cohort study using Veterans Affairs and Medicare administrative data. Male Veterans (n=5,036,536) aged 50-99 years receiving VA primary care between1999-2009 were included. Fractures were ascertained using ICD9 and CPT codes and classified by skeletal site. Pearson correlation coefficients, logistic regression and kappa statistics, were used to describe the correlation between each fracture type and hip fracture within individuals, without regards to the timing of the events. Results 595,579 (11.8%) men suffered 1 or more fractures and 179,597 (3.6%) suffered 2 or more fractures during the time under study. Of those with one or more fractures, rib was the most common site (29%), followed by spine (22%), hip (21%) and femur (20%). The fracture types most highly correlated with hip fracture were pelvic/acetabular (Pearson correlation coefficient 0.25, p<0.0001), femur (0.15, p<0.0001), and shoulder (0.11, p<0.0001). Conclusions Pelvic, acetabular, femur, and shoulder fractures cluster with hip fractures within individuals at greater than expected frequency. If we observe similar treatment risk reductions within that cluster, subsequent trials could consider use of a composite endpoint to better estimate hip fracture risk. PMID:26151123

  7. Methods for estimation and enhancing of resistance of pressure vessel materials to fracture at different stages of service taking into account actual dimensions of the construction

    International Nuclear Information System (INIS)

    Pokrovsky, V.V.; Ivanchenko, A.G.

    1998-01-01

    In the present report a method is proposed for assessment of cracked materials fracture toughness over a wide range of temperatures taking into account the size-effect of structural elements. The procedure proposed was evaluated on specimens of different thicknesses (25... 150 mm) and geometries from the parent metal and welded joint metal of the WWER-Type nuclear reactor pressure vessels of different classes of strength. The method of enhancing of fracture resistance of pressure vessel materials has been develop which is based on warm prestressing of materials with cracks. The stability of the favourable effect of the warm prestressing has been, investigated and shown for the above steels after their long term (to 24000 hours) keeping under static loading and temperature of 350 deg C, under different conditions of cyclic loading, corrosive action. A model and calculation procedure are proposed for predicting the influence of thermomechanical loading conditions on the resistance of reactor steels to brittle fracture. (authors)

  8. Investigation of translaminar fracture in fibrereinforced composite laminates---applicability of linear elastic fracture mechanics and cohesive-zone model

    Science.gov (United States)

    Hou, Fang

    With the extensive application of fiber-reinforced composite laminates in industry, research on the fracture mechanisms of this type of materials have drawn more and more attentions. A variety of fracture theories and models have been developed. Among them, the linear elastic fracture mechanics (LEFM) and cohesive-zone model (CZM) are two widely-accepted fracture models, which have already shown applicability in the fracture analysis of fiber-reinforced composite laminates. However, there remain challenges which prevent further applications of the two fracture models, such as the experimental measurement of fracture resistance. This dissertation primarily focused on the study of the applicability of LEFM and CZM for the fracture analysis of translaminar fracture in fibre-reinforced composite laminates. The research for each fracture model consisted of two sections: the analytical characterization of crack-tip fields and the experimental measurement of fracture resistance parameters. In the study of LEFM, an experimental investigation based on full-field crack-tip displacement measurements was carried out as a way to characterize the subcritical and steady-state crack advances in translaminar fracture of fiber-reinforced composite laminates. Here, the fiber-reinforced composite laminates were approximated as anisotropic solids. The experimental investigation relied on the LEFM theory with a modification with respect to the material anisotropy. Firstly, the full-field crack-tip displacement fields were measured by Digital Image Correlation (DIC). Then two methods, separately based on the stress intensity approach and the energy approach, were developed to measure the crack-tip field parameters from crack-tip displacement fields. The studied crack-tip field parameters included the stress intensity factor, energy release rate and effective crack length. Moreover, the crack-growth resistance curves (R-curves) were constructed with the measured crack-tip field parameters

  9. Gas hydrate saturations estimated from fractured reservoir at Site NGHP-01-10, Krishna-Godavari Basin, India

    Science.gov (United States)

    Lee, M.W.; Collett, T.S.

    2009-01-01

    During the Indian National Gas Hydrate Program Expedition 01 (NGHP-Ol), one of the richest marine gas hydrate accumulations was discovered at Site NGHP-01-10 in the Krishna-Godavari Basin. The occurrence of concentrated gas hydrate at this site is primarily controlled by the presence of fractures. Assuming the resistivity of gas hydratebearing sediments is isotropic, th?? conventional Archie analysis using the logging while drilling resistivity log yields gas hydrate saturations greater than 50% (as high as ???80%) of the pore space for the depth interval between ???25 and ???160 m below seafloor. On the other hand, gas hydrate saturations estimated from pressure cores from nearby wells were less than ???26% of the pore space. Although intrasite variability may contribute to the difference, the primary cause of the saturation difference is attributed to the anisotropic nature of the reservoir due to gas hydrate in high-angle fractures. Archie's law can be used to estimate gas hydrate saturations in anisotropic reservoir, with additional information such as elastic velocities to constrain Archie cementation parameters m and the saturation exponent n. Theory indicates that m and n depend on the direction of the measurement relative to fracture orientation, as well as depending on gas hydrate saturation. By using higher values of m and n in the resistivity analysis for fractured reservoirs, the difference between saturation estimates is significantly reduced, although a sizable difference remains. To better understand the nature of fractured reservoirs, wireline P and S wave velocities were also incorporated into the analysis.

  10. Effect of microplastic strain on hydrogen behaviour in steel and resistance to hydrogen embrittlement

    Energy Technology Data Exchange (ETDEWEB)

    Gribanova, L.I.; Sarrak, V.I.; Filippov, G.A.; Shlyafirner, A.M. (Tsentral' nyj Nauchno-Issledovatel' skij Inst. Chernoj Metallurgii, Moscow (USSR))

    1981-01-01

    A connection between the tendency to delayed fracture and resistance to microplastic deformation is studied in the presence of hydrogen on smooth samples of the 40Kh steel. Tests for delayed fracture have been carried out at the ''Instron'' machine. Two critical levels of strains during delayed fracture in the hydridation process are found out (sigmasub(cr1)=0.3sigmasub(0.2) and sigmasub(cr2)=0.5sigmasub(0.2)). At stresses below the sigmasub(cr1) hydrogen does not influence on the resistance to microplastic deformation of steel and does not cause delayed fracture. Propagation of cracks arising from defects occurring as a result of mutual effect of hydrogen and elastic stresses runs in the stress range from sigmasub(cr1) up to sigmasub(cr2). At stresses higher than sigmasub(cr2) the crack propagates from defects existing in the moment of hydridation process beginning.

  11. Effect of Nb on hydrogen-induced delayed fracture in high strength hot stamping steels

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Shiqi [School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); College of Mechanical Engineering, Yangtze University, Jingzhou 434023 (China); Huang, Yunhua, E-mail: huangyh@mater.ustb.edu.cn [School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Sun, Bintang, E-mail: bingtangsun@ustb.edu.cn [School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Liao, Qingliang [School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Lu, Hongzhou [CITIC Metal Co. Ltd., Room 1901, Capital Mansion 6, Xin Yuan Nanlu, Chaoyang District, Beijing 100004 (China); The School of Resources and Environmental Engineering, East China University of Science and Technology, Meilong road 130, Xujiahui District, Shanghai 200237 (China); Jian, Bian [Niobium Tech Asia, 068898 Singapore (Singapore); Mohrbacher, Hardy [NiobelCon bvba, 2970 Schilde (Belgium); Zhang, Wei; Guo, Aimin [CITIC Metal Co. Ltd., Room 1901, Capital Mansion 6, Xin Yuan Nanlu, Chaoyang District, Beijing 100004 (China); Zhang, Yue [School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); The State Key Laboratory for Advanced Metals and Materials, University of Science and Technology Beijing, Beijing 100083 (China)

    2015-02-25

    The effect of Nb addition (0.022, 0.053, 0.078 wt%) on the hydrogen-induced delayed fracture resistance of 22MnB5 was studied by constant load test and electrochemical hydrogen permeation method. It is shown that the appropriate addition of Nb is beneficial to the improvement of the delayed fracture resistance of tested steel, especially when the steel contains high concentration of hydrogen, and the maximum delayed fracture resistance is obtained at a Nb content of 0.053%.The result of hydrogen permeation test shows that the diffusion coefficient of hydrogen in the steel containing niobium is lower than that in steel without niobium, which indicates that it is harder for hydrogen in the steels containing niobium to diffuse and aggregate. In addition, the reason for Nb improving the delayed fracture resistance of steels is discussed from two aspects: hydrogen trap effect and grain refinement effect. The analysis shows that the main reason leading to the improvement of the delayed fracture resistance is the hydrogen trapping effect of NbC while the grain refinement effect of Nb(C,N) secondary.

  12. Effect of Nb on hydrogen-induced delayed fracture in high strength hot stamping steels

    International Nuclear Information System (INIS)

    Zhang, Shiqi; Huang, Yunhua; Sun, Bintang; Liao, Qingliang; Lu, Hongzhou; Jian, Bian; Mohrbacher, Hardy; Zhang, Wei; Guo, Aimin; Zhang, Yue

    2015-01-01

    The effect of Nb addition (0.022, 0.053, 0.078 wt%) on the hydrogen-induced delayed fracture resistance of 22MnB5 was studied by constant load test and electrochemical hydrogen permeation method. It is shown that the appropriate addition of Nb is beneficial to the improvement of the delayed fracture resistance of tested steel, especially when the steel contains high concentration of hydrogen, and the maximum delayed fracture resistance is obtained at a Nb content of 0.053%.The result of hydrogen permeation test shows that the diffusion coefficient of hydrogen in the steel containing niobium is lower than that in steel without niobium, which indicates that it is harder for hydrogen in the steels containing niobium to diffuse and aggregate. In addition, the reason for Nb improving the delayed fracture resistance of steels is discussed from two aspects: hydrogen trap effect and grain refinement effect. The analysis shows that the main reason leading to the improvement of the delayed fracture resistance is the hydrogen trapping effect of NbC while the grain refinement effect of Nb(C,N) secondary

  13. Fracture resistance of prepared premolars restored with bonded new lab composite and all-ceramic inlay/onlay restorations: Laboratory study.

    Science.gov (United States)

    Wafaie, Ramy Ahmed; Ibrahim Ali, Ashraf; Mahmoud, Salah Hasab

    2018-01-25

    To assess the influence of new light curing lab composite, lithium-disilicate glass-ceramic and yttrium-stabilized zirconia-based ceramic on the fracture resistance of maxillary premolars with class II inlay and onlay preparations. Seventy sound maxillary premolars were divided randomly into seven main groups. The first group was left intact (control group). The remaining six groups were prepared with inlay and onlay cavities and restored with lab composite (SR Nexco), lithium-disilicate glass-ceramic (IPS e.max Press) and yttrium-stabilized zirconia-based ceramic (ICE Zirkon). The restorations were cemented with luting resin composite (Variolink N). All specimens were thermocycled 5000 cycles between 5°C ± 2°C and 55°C ± 2°C and were then cyclic loaded for 500 000 cycles. The specimens were subjected to a compressive load in a universal testing machine using a metal sphere until fracture occurred. The results were analyzed by 2-way ANOVA and Tukey HSD post hoc tests. The level of significance was set at P  .05). However, statistically significant differences were found among the means of control group and the groups restored with lab composite inlays, lab composite onlays, pressable glass ceramic inlays and pressable glass ceramic onlays (P lab composite is used. Conversely, when a ceramic material being used, the prepared teeth for inlay and onlay restorations showed a comparable strength to the intact teeth especially zirconia ceramic. Premolar teeth restored with zirconia ceramic inlays and onlays exhibited fracture resistance comparable to intact teeth. © 2018 Wiley Periodicals, Inc.

  14. Multidimensional Nanocomposites of Epoxy Reinforced with 1D and 2D Carbon Nanostructures for Improve Fracture Resistance

    Directory of Open Access Journals (Sweden)

    Juventino López-Barroso

    2018-03-01

    Full Text Available A hybrid nanocomposites based on epoxy reinforced with a combination of 1D and 2D carbon nanomaterials for improving impact resistance are reported. Multi-walled carbon nanotubes and oxidized-multi-walled carbon nanotubes are used as 1D nanoreinforcements, and graphene derivative materials such as graphene oxide and reduced graphene oxide are utilized as 2D nanoreinforcements. In this research, the impact resistance of epoxy matrix reinforced with 1D or 2D and the mixture of both nanomaterials is studied. The research is focused on evaluation of the influence of adding different combinations of nanomaterials into epoxy resin and their Izod impact response. Moreover, fracture surface of nanocomposites is observed by scanning electron microscopy. Images show differences between the surfaces of brittle nature on thermoset epoxy polymer and tough nanocomposites. Synergy created with 1D and 2D nanomaterials produces stable dispersions in the processing, reflected in the interface. The interactions in nanocomposites are evidenced by infrared spectra, principally on the peaks related to oxygenated functional groups present in nanomaterials and absent in polymer matrix. Consequently, an increase of 138% in fracture strength of nanocomposites is exhibited, in comparison to the neat epoxy matrix. In addition, hybrid nanocomposites were synthesized in two different methods to evaluate the influence of manufacturing method on final properties of nanocomposites.

  15. No Higher Risk of CRPS After External Fixation of Distal Radial Fractures - Subgroup Analysis Under Randomised Vitamin C Prophylaxis.

    Science.gov (United States)

    Zollinger, Paul E; Kreis, Robert W; van der Meulen, Hub G; van der Elst, Maarten; Breederveld, Roelf S; Tuinebreijer, Wim E

    2010-02-17

    Operative and conservative treatment of wrist fractures might lead to complex regional pain syndrome (CRPS) type I.In our multicenter dose response study in which patients with distal radial fractures were randomly allocated to placebo or vitamin C in a daily dose of 200mg, 500mg or 1500mg during 50 days, an operated subgroup was analyzed.48 (of 427) fractures) were operated (11.2%). Twenty-nine patients (60%) were treated with external fixation, 14 patients (29%) with K-wiring according to Kapandji and five patients (10%) with internal plate fixation. The 379 remaining patients were treated with a plaster.In the operated group of patients who received vitamin C no CRPS (0/37) was seen in comparison with one case of CRPS (Kapandji technique) in the operated group who received placebo (1/11 = 9%, p=.23). There was no CRPS after external fixation.In the conservatively treated group 17 cases of CRPS (17/379 = 4.5%) occurred in comparison with one in case of CRPS in the operated group (1/48 = 2.1%, p=.71).External fixation doesn't necessarily lead to a higher incidence of CRPS in distal radial fractures. Vitamin C may also play a role in this. This subgroup analysis in operated distal radial fractures showed no CRPS occurrence with vitamin C prophylaxis.

  16. Influence of structure on static cracking resistance and fracture of welded joints of pipe steels of strength class K60

    Science.gov (United States)

    Tereshchenko, N. A.; Tabatchikova, T. I.; Yakovleva, I. L.; Makovetskii, A. N.; Shander, S. V.

    2017-07-01

    The static cracking resistance of a number of welded joints made from pipe steels of K60 strength class has been determined. It has been established that the deformation parameter CTOD varies significantly at identical parameters of weldability of steels. The character of fracture has been investigated and the zone of local brittleness of welded joints has been studied. It has been shown that the ability of a metal to resist cracking is determined by the austenite grain size and by the bainite morphology in the region of overheating in the heat-affected zone of a welded joint.

  17. Stress and gas hydrate-filled fracture distribution, Krishna-Godavari Basin, India

    Energy Technology Data Exchange (ETDEWEB)

    Cook, A.; Goldberg, D. [Lamont-Doherty Earth Observatory of Columbia Univ., Palisades, NY (United States)

    2008-07-01

    The first expedition of the Indian National Gas Hydrate Program (NGHP) was launched in the summer of 2006 to characterize the presence of gas hydrates on the continental margins of India. This paper presented a study from the NGHP expedition that found high resistivity fractures in unconsolidated clay sediments on logging-while-drilling (LWD) borehole resistivity images. Gas hydrate-filled and conductive fractures appearing on LWD resistivity images in holes 5A, 5B, 6A, 7A and 10 were analysed and discussed. Fracture orientation and shallow sediment stress orientations were determined for each hole. The paper described how to determine which sections of a log are hydrate bearing as well as how to calculate the predicted water saturated resistivity. It was concluded that holes 5A, 5B, 6A and 7A contained well-ordered, high-angle fractures, from which horizontal stress directions could be accurately resolved. However, these stress directions, contradicted the orientations normally seen on a passive margin, and may be the result of local bathymetry variations. 6 refs., 1 tab., 11 figs.

  18. Compressive fracture resistance of the marginal ridge in large Class II tunnels restored with cermet and composite resin.

    Science.gov (United States)

    Ehrnford, L E; Fransson, H

    1994-01-01

    Compressive fracture resistance of the marginal ridge was studied in large tunnel preparations, before and after restoration with cermet (Ketac Silver, ESPE), a universal hybrid composite (Superlux, DMG) and an experimental composite. Each group was represented by six tunnels in extracted upper premolars. The tunnels were prepared by the use of round burs up to size #6. Remaining ridge width was 1.5 mm and ridge height 1.7 mm in the contact area. The ridge was loaded to fracture by a rod placed perpendicular to the ridge. Generally this resulted in a shear fracture of the restoration. There was no significant reinforcement of the ridge by the cermet whereas the composites both reinforced by the same magnitude, averaging 62%. It was concluded that the ridge could be considered a "megafiller" where contact need to be preserved and contour protected against proximal and occlusal wear of the restoration. Clinically there would therefore be good reasons to save even ridge areas with very low inherent strength. Based on the present study composite resin might therefore be the filling material of choice for such tunnel preparations.

  19. Comparison of fracture resistance between cast, CAD/CAM milling, and direct metal laser sintering metal post systems.

    Science.gov (United States)

    Bilgin, Mehmet Selim; Erdem, Ali; Dilber, Erhan; Ersoy, İbrahim

    2016-01-01

    The purpose of this study was to compare the fracture resistance of Co-Cr post-cores fabricated with 3 different techniques: traditional casting (TC), computer-aided design and manufacturing (CAD/CAM) milling (CCM) and direct metal laser sintering (DMLS). Forty intact human mandibular premolar were endodontically treated. The roots were then randomly divided into four groups according to the post systems: the control group was only filled with gutta percha. Co-Cr metal posts were fabricated with TC, CCM and DMLS in the other three groups. The posts were luted with a resin cement and subjected to compression test at a crosshead speed of 1mm/min. The statistical analysis of the data was performed using one-way analysis of variance (ANOVA) and multiple comparison post hoc Tukey tests (α=.05). The samples were examined under a stereomicroscope with ×20 magnification for the evaluation of the fracture types. The mean fracture loads were 432.69 N for control, 608.89 N for TC, 689.40 N for DMLS and 959.26 N for CCM. One-way ANOVA revealed significant difference between the groups (pmetal posts fabricated by CCM and DMLS could be an alternative to TC processing in daily clinical application. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  20. Fracture toughness of a nanoscale WC-Co tool steel

    International Nuclear Information System (INIS)

    Densley, J.M.; Hirth, J.P.

    1997-01-01

    Tungsten carbide tool steels, comprising WC particles with 6.7--25wt% Co distributed in the interparticle regions as a quasi-continuous binder phase, can be considered as WC-Co composites. The fracture toughness of such WC-Co composites is dependent on the volume fraction, contiguity and thickness of the cobalt binder, and the size of the tungsten carbide grains. Research has shown that the ductile binder undergoes nearly all the plastic deformation during fracture, which provides the primary energy consuming process that enhances fracture resistance. Recent manufacturing developments have given rise to the production of a WC-6.7wt% Co cermet having an average WC grain size of 70 nm, with a corresponding binder mean thickness, h, of 9 nm calculated from d = h(1-V f )/V f where d = 70 nm and V f = 0.114. This composite has shown a higher wear resistance than that of conventional cermets in proportion to their hardness. Such improvement has been attributed to the difficulty in forming dislocations in the very small grains. There are also indications that the Co binder in the nanoscale cermet contains higher contents of dissolved W and C than for conventional scale cermets. Because plastic deformation is initially confined to the binder phase, it was of interest to perform mode 1 and mixed mode toughness tests on the nanoscale cermet to determine whether flow localization influenced mixed mode toughness as in bulk materials. Two generations of this cermet were provided by Rogers Tool Works. The first generation, A, had lower binder contiguity, with occasional agglomerations of WC grains. The second generation, B, was cleaner, with the cobalt binder more uniformly separating the WC grains

  1. Loading rate effects on strength and fracture toughness of pipe steels used in Task 1 of the IPIRG program

    International Nuclear Information System (INIS)

    Marschall, C.W.; Landow, M.P.; Wilkowski, G.M.

    1993-10-01

    Material characterization tests were conducted on laboratory specimens machined from pipes to determine the effect of dynamic loading (i.e., rates comparable to those for high amplitude seismic events) on tensile properties and fracture resistance at 288 C (550 F). Specimens were fabricated from seven different pipes, including carbon steels and stainless steels (both base metal and weld metal), which were to be subjected to full-scale pipe tests in IPIRG Task 1.0. For the stainless steels tested at 288 C (550 F), tensile strength was unchanged, while yield strength and fracture resistance were increased. The increase in fracture resistance was modest for the wrought base metals and substantial for the weld metal and the cast base metal. The carbon steels tested were sensitive to dynamic strain aging, and hence the strength and toughness was affected by both temperature and strain rate effects. The carbon steel base metal and welds exhibited ultimate tensile strength values at 288 C (550 F) that were greater than at room temperature. Furthermore, the ultimate tensile strength at 288 C (550 F) was lowered significantly by increased strain rate and, in the carbon steel base metals, increased strain rate also lowered the fracture resistance, substantially in the base metal of one pipe. In comparing these results to the IPIRG pipe test results to date, it was found that the trends of these tests agree well with the Subtask 1.2 quasi-static and dynamic pipe fracture experiments. Loads measured in the Subtask 1.1 pipe experiments were, however, somewhat higher than would have been expected by the trends observed in the laboratory tests

  2. Pre-fracture individual characteristics associated with high total health care costs after hip fracture.

    Science.gov (United States)

    Schousboe, J T; Paudel, M L; Taylor, B C; Kats, A M; Virnig, B A; Dowd, B E; Langsetmo, L; Ensrud, K E

    2017-03-01

    Older women with pre-fracture slow walk speed, high body mass index, and/or a high level of multimorbidity have significantly higher health care costs after hip fracture compared to those without those characteristics. Studies to investigate if targeted health care interventions for these individuals can reduce hip fracture costs are warranted. The aim of this study is to estimate the associations of individual pre-fracture characteristics with total health care costs after hip fracture, using Study of Osteoporotic Fractures (SOF) cohort data linked to Medicare claims. Our study population was 738 women age 70 and older enrolled in Medicare Fee for Service (FFS) who experienced an incident hip fracture between January 1, 1992 and December 31, 2009. We assessed pre-fracture individual characteristics at SOF study visits and estimated costs of hospitalizations, skilled nursing facility and inpatient rehabilitation stays, home health care visits, and outpatient utilization from Medicare FFS claims. We used generalized linear models to estimate the associations of predictor variables with total health care costs (2010 US dollars) after hip fracture. Median total health care costs for 1 year after hip fracture were $35,536 (inter-quartile range $24,830 to $50,903). Multivariable-adjusted total health care costs for 1 year after hip fracture were 14 % higher ($5256, 95 % CI $156 to $10,356) in those with walk speed total health care costs after hip fracture in older women. Studies to investigate if targeted health care interventions for these individuals can reduce the costs of hip fractures are warranted.

  3. The efficacy of rotational control designs in promoting torsional stability of hip fracture fixation.

    Science.gov (United States)

    Gosiewski, J D; Holsgrove, T P; Gill, H S

    2017-05-01

    Fractures of the proximal femur are a common clinical problem, and a number of orthopaedic devices are available for the treatment of such fractures. The objective of this study was to assess the rotational stability, a common failure predictor, of three different rotational control design philosophies: a screw, a helical blade and a deployable crucifix. Devices were compared in terms of the mechanical work (W) required to rotate the implant by 6° in a bone substitute material. The substitute material used was Sawbones polyurethane foam of three different densities (0.08 g/cm 3 , 0.16 g/cm 3 and 0.24 g/cm 3 ). Each torsion test comprised a steady ramp of 1°/minute up to an angular displacement of 10°. The deployable crucifix design (X-Bolt), was more torsionally stable, compared to both the dynamic hip screw (DHS, p = 0.008) and helical blade (DHS Blade, p= 0.008) designs in bone substitute material representative of osteoporotic bone (0.16 g/cm 3 polyurethane foam). In 0.08 g/cm 3 density substrate, the crucifix design (X-Bolt) had a higher resistance to torsion than the screw (DHS, p = 0.008). There were no significant differences (p = 0.101) between the implants in 0.24 g/cm 3 density bone substitute. Our findings indicate that the clinical standard proximal fracture fixator design, the screw (DHS), was the least effective at resisting torsional load, and a novel crucifix design (X-Bolt), was the most effective design in resisting torsional load in bone substitute material with density representative of osteoporotic bone. At other densities the torsional stability was also higher for the X-Bolt, although not consistently significant by statistical analysis. Cite this article : J. D. Gosiewski, T. P. Holsgrove, H. S. Gill. The efficacy of rotational control designs in promoting torsional stability of hip fracture fixation. Bone Joint Res 2017;6:270-276. DOI: 10.1302/2046-3758.65.BJR-2017-0287.R1. © 2017 Gosiewski et al.

  4. Assessment of copper resistance to stress-corrosion cracking in nitrite solutions by means of joint analysis of acoustic emission measurements, deformation diagrams, qualitative and quantitative fractography, and non-linear fracture mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Khanzhin, V.G.; Nikulin, S.A. [Moscow State Inst. of Steel and Alloys (Russian Federation)

    2005-06-01

    A study of stress-corrosion cracking (SCC) of copper in 0.1M NaNO{sub 2} aqueous solution is presented. The fracture kinetics was monitored by measuring the acoustic emission (AE) signals. Macro- and micro-fractography analysis, using scanning electron microscopy (SEM), was employed to investigate the fracture mechanisms. Estimates of stress intensity factor, KI, and J-integral were derived in order to assess the resistance of copper to stress corrosion cracking. Two kinds of SCC tests under continuous circulation of the corrosive solution were employed in the present study: 1. Constant extension rate (2x10{sup -6}/s) tests on pre-cracked, middle tension (MT) panel specimens. 2. Tests on pre-cracked, compact tension (CT) specimens at a fixed (by a fixing bolt) opening of the crack walls ({delta} = 0.3 mm, K{sub i} = 27 MPax{radical}m). The time base for these tests was about two months. After the completion of the SCC test, the CT specimen was additionally tested, under a constant-rate (0.02 mm/s) off-center extension. In the both kinds of tests, the SCC fracture kinetics is found to exhibit two typical stages: Stage 1: SCC initiation stage (after a certain incubation period, T{sub i}, measured to be T{sub i} {approx_equal} 3-4 hours for MT specimens under constant extension, the corresponding stress was {sigma} {approx_equal} 40-70 MPa, and T{sub i} {approx_equal} 200 hours for CT specimens under a fixed crack wall opening). Stage 2: Active fracture process (SCC macro-fracture) distinguished by strong AE pulses (which are registered after time T{sub 2} {approx_equal} 8 hours for MT specimens and T{sub 2} {approx_equal} 800 hours for CT specimens). Fractography analysis has shown that the zone of SCC fracture in MT specimens extends to approximately 1,500 {mu}m. A 400-700 {mu}m deep zone of brittle transgranular fracture, which included small areas showing characteristic SCC 'striations', was observed adjacent to the fatigue pre-crack area. At higher

  5. High resolution resistivity measurements at the Down Ampney research site

    International Nuclear Information System (INIS)

    Hallam, J.R.; Jackson, P.D.; Rainsbury, M.; Raines, M.

    1991-01-01

    A new high resolution resistivity surveying method is described for fault detection and characterisation. The resolution is shown to be significantly higher than conventional apparent resistivity profiling when applied to geological discontinuities such as faults. Nominal fault locations have been determined to an accuracy of 0.5 m, as proven by drilling. Two dimensional profiling and image enhancement of the resulting 2-D data set indicated the possibility of subsidiary fractures and/or lateral changes within the clay to clay' fault zone. The increased resolution allows greater confidence to be placed on both the fault detection and lateral perturbations derived from processed resistance and resistivity images. (Author)

  6. Fractographic peculiarities of cermet tungsten fracture

    International Nuclear Information System (INIS)

    Stepanenko, V.A.; Babak, A.V.; Uskov, E.I.

    1982-01-01

    Effect of test temperature on fracture peculiarities of cermets tungsten with initial cellular structure of deformation is shown. Tungsten crack resistance increases at temperatures to Tsub(x) (ductile-brittle transition temperature) and decreases at temperatures above Tsub(x). The degree of ceramics tungsten plasticity realization depends on its crack resistance

  7. Evaluation of Fibular Fracture Type vs Location of Tibial Fixation of Pilon Fractures.

    Science.gov (United States)

    Busel, Gennadiy A; Watson, J Tracy; Israel, Heidi

    2017-06-01

    Comminuted fibular fractures can occur with pilon fractures as a result of valgus stress. Transverse fibular fractures can occur with varus deformation. No definitive guide for determining the proper location of tibial fixation exists. The purpose of this study was to identify optimal plate location for fixation of pilon fractures based on the orientation of the fibular fracture. One hundred two patients with 103 pilon fractures were identified who were definitively treated at our institution from 2004 to 2013. Pilon fractures were classified using the AO/OTA classification and included 43-A through 43-C fractures. Inclusion criteria were age of at least 18 years, associated fibular fracture, and definitive tibial plating. Patients were grouped based on the fibular component fracture type (comminuted vs transverse), and the location of plate fixation (medial vs lateral) was noted. Radiographic outcomes were assessed for mechanical failures. Forty fractures were a result of varus force as evidenced by transverse fracture of the fibula and 63 were due to valgus force with a comminuted fibula. For the transverse fibula group, 14.3% mechanical complications were noted for medially placed plate vs 80% for lateral plating ( P = .006). For the comminuted fibular group, 36.4% of medially placed plates demonstrated mechanical complications vs 16.7% for laterally based plates ( P = .156). Time to weight bearing as tolerated was also noted to be significant between groups plated medially and laterally for the comminuted group ( P = .013). Correctly assessing the fibular component for pilon fractures provides valuable information regarding deforming forces. To limit mechanical complications, tibial plates should be applied in such a way as to resist the original deforming forces. Level of Evidence Level III, comparative study.

  8. Evaluation of WWER-1000 vessel materials fracture toughness

    International Nuclear Information System (INIS)

    Grinik, Eh.U.; Revka, V.N.; Chirko, L.I.; Chajkovskij, Yu.V.

    2007-01-01

    The lifetime of WWER-1000-type reactor vessels is finally conditioned by the fracture toughness (crack growth resistance) of RPV materials. Up to now in line with the regulations the fracture toughness is characterized by the critical temperature of brittleness determined by the results of the Charpy specimen impact testing. Such approach is typical for all countries operating the water pressure reactors. However, regulatory approach is known from the western specialists not always to characterize adequately the crack growth resistance of the vessel materials and in some cases to underestimate their characteristics in the reference state that leads to unreasonably high conservatism. Excessive conservatism may lead to the invalid restrictions in the operating modes and the service life of the reactor vessel. Therefore there appeared the necessity to apply another approaches based on the state-of-the-art experimental methods of the fracture mechanics and allowing evaluating the fracture toughness parameters sufficiently. The paper presents the results of the comparison of the regulatory approach and the Master curve approach from the point of view of the adequate determination of the vessel material crack growth resistance parameters. Analysis of the experimental data of the surveillance specimens illustrated the potential possibility of applying the new statistical method for the WWER-1000- type reactor vessel lifetime extension

  9. On the effect of x-ray irradiation on the deformation and fracture behavior of human cortical bone

    Energy Technology Data Exchange (ETDEWEB)

    Barth, Holly D.; Launey, Maximilien E.; McDowell, Alastair A.; Ager III, Joel W.; Ritchie, Robert O.

    2010-01-10

    In situ mechanical testing coupled with imaging using high-energy synchrotron x-ray diffraction or tomography imaging is gaining in popularity as a technique to investigate micrometer and even sub-micrometer deformation and fracture mechanisms in mineralized tissues, such as bone and teeth. However, the role of the irradiation in affecting the nature and properties of the tissue is not always taken into account. Accordingly, we examine here the effect of x-ray synchrotron-source irradiation on the mechanistic aspects of deformation and fracture in human cortical bone. Specifically, the strength, ductility and fracture resistance (both work-of-fracture and resistance-curve fracture toughness) of human femoral bone in the transverse (breaking) orientation were evaluated following exposures to 0.05, 70, 210 and 630 kGy irradiation. Our results show that the radiation typically used in tomography imaging can have a major and deleterious impact on the strength, post-yield behavior and fracture toughness of cortical bone, with the severity of the effect progressively increasing with higher doses of radiation. Plasticity was essentially suppressed after as little as 70 kGy of radiation; the fracture toughness was decreased by a factor of five after 210 kGy of radiation. Mechanistically, the irradiation was found to alter the salient toughening mechanisms, manifest by the progressive elimination of the bone's capacity for plastic deformation which restricts the intrinsic toughening from the formation 'plastic zones' around crack-like defects. Deep-ultraviolet Raman spectroscopy indicated that this behavior could be related to degradation in the collagen integrity.

  10. Cyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canals.

    Science.gov (United States)

    Özyürek, Taha; Gündoğar, Mustafa; Uslu, Gülşah; Yılmaz, Koray; Staffoli, Simone; Nm, Grande; Plotino, Gianluca; Polimeni, Antonella

    2018-01-30

    The aim of the present study was to compare the cyclic fatigue resistances of HyFlex EDM (HEDM), WaveOne Gold (WOG), Reciproc Blue (RB), and 2Shape (TS) NiTi systems having different metallurgic properties. HEDM, WOG, RB, and TS instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 45°, and 90° angles of curvatures and a radius of curvature of 5 mm until fracture occurred, and the time to fracture (TTF) was recorded in seconds. Also, number of cycles to fracture was calculated (NCF). Data were statistically analyzed using Kruskal-Wallis and t test. The statistical significance level was set at P  0.05). When the NCF values were taken into consideration, HEDM reported a significantly higher cyclic fatigue resistance than TS in both canal curvatures analyzed (P < 0.05). Within the limitations of the present study, RB NiTi files showed statistically higher cyclic fatigue resistance in artificial canals with 45° and 90° than the other NiTi files tested.

  11. Avulsion fractures of the scapula

    International Nuclear Information System (INIS)

    Heyse-Moore, G.H.; Stoker, D.J.

    1982-01-01

    Fractures of the scapula due to direct violence are relatively common. Wilber and Evans [18] reported 40 scapular fractures and reviewed the literature. All those injured has received direct trauma to the shoulder and they were able to divide their cases into two groups, based on anatomical location and functional results. Scapular fractures due to avulsion of the muscular attachments are uncommon and, as reports of these injuries in the literature are usually confined to single cases, no classification has been established which takes account of the anatomical sites at which these fractures occur and the mechanism of injury involved. In this paper the more common sites of avulsion injury of the scapula are described and illustrated by case reports. In several of these the skeletal injury resulted from muscle contraction against a resisted force on the upper limb during the course of an accident. This mechanism has been implicated in fractures of the coracoid and acromion, but is shown in this paper to contribute to other avulsion fractures. (orig.)

  12. Ductile fracture of two-phase welds under 77K

    International Nuclear Information System (INIS)

    Yushchenko, K.A.; Voronin, S.A.; Pustovit, A.I.; Shavel', A.V.

    1984-01-01

    The effect of the type of welding and fillers on crack resistance of welded joints high-strength steel EhP810 and its various compounds with steels EhP666, 08Kh18N10T has been studied. For the welding of steel EhP810 with steels EhP810, EhP666, 08Kh18N10T electron-beam, automatic, argon tungsten arc with non-consumable electrode with various fillers, as well as argon metal-arc welding with consumable electrode, were used. It is shown, that for a joint, made by electron-beam welding, parameters σsub(u), Ksub(IcJ), KCV are higher than for a joint of a similar phase structure made using filler wire EhP659-VI. It is explained by the fact, that during electron-beam welding joint metal refining takes place, which removes gases. In welded joints of chP810 steel, having joints with austenitic structure, characteristic of crack resistance Ssub(c) increases by more than 0.2 mm in contrast to two-phase joints, which conventional yield strength at 77 K exceeds 1000 MPa. It is worth mentioning, that for other classes of steels formation of two-phase structure of joint increases welded joint resistance to brittle fracture. It is possible to obtain the required structure of joint with assigned level of resistance to brittle fracture by means of the use of different fillers, optimum and welding procedure, regulaing the part of the basic metal in joint content

  13. The effect of loading rate on ductile fracture toughness and fracture surface roughness

    DEFF Research Database (Denmark)

    Osovski, S.; Srivastava, Akhilesh Kumar; Ponson, L.

    2015-01-01

    The variation of ductile crack growth resistance and fracture surface roughness with loading rate is modeled under mode I plane strain, small scale yielding conditions. Three-dimensional calculations are carried out using an elastic-viscoplastic constitutive relation for a progressively cavitatin...

  14. Ductile fracture theories for pressurised pipes and containers

    Science.gov (United States)

    Erdogan, F.

    1976-01-01

    Two mechanisms of fracture are distinguished. Plane strain fractures occur in materials which do not undergo large-scale plastic deformations prior to and during a possible fracture deformation. Plane stress or high energy fractures are generally accompanied by large inelastic deformations. Theories for analyzing plane stress are based on the concepts of critical crack opening stretch, K(R) characterization, J-integral, and plastic instability. This last is considered in some detail. The ductile fracture process involves fracture initiation followed by a stable crack growth and the onset of unstable fracture propagation. The ductile fracture propagation process may be characterized by either a multiparameter (discrete) model, or some type of a resistance curve which may be considered as a continuous model expressed graphically. These models are studied and an alternative model is also proposed for ductile fractures which cannot be modeled as progressive crack growth phenomena.

  15. Management of fractures in field settings.

    Science.gov (United States)

    Anderson, David E; St Jean, Guy

    2008-11-01

    Limb fractures are common in farm animals, are most commonly found in young stock, and often occur subsequent to trauma during dystocia or handling. Cattle are excellent patients for treatment of orthopedic injuries because they spend a majority of time lying down, have a tremendous potential for bone healing, are more resistant than other animals to contralateral limb breakdown and stress laminitis, and usually do not resist having orthopedic devices on their limbs. This article describes management of fractures, especially for cattle, in field settings; explains how the principles of external skeletal fixation are adapted for cattle; discusses the application of external skeletal fixation to individual bones, and reviews potential complications in the use of external skeletal fixation.

  16. Facial Fractures.

    Science.gov (United States)

    Ghosh, Rajarshi; Gopalkrishnan, Kulandaswamy

    2018-06-01

    The aim of this study is to retrospectively analyze the incidence of facial fractures along with age, gender predilection, etiology, commonest site, associated dental injuries, and any complications of patients operated in Craniofacial Unit of SDM College of Dental Sciences and Hospital. This retrospective study was conducted at the Department of OMFS, SDM College of Dental Sciences, Dharwad from January 2003 to December 2013. Data were recorded for the cause of injury, age and gender distribution, frequency and type of injury, localization and frequency of soft tissue injuries, dentoalveolar trauma, facial bone fractures, complications, concomitant injuries, and different treatment protocols.All the data were analyzed using statistical analysis that is chi-squared test. A total of 1146 patients reported at our unit with facial fractures during these 10 years. Males accounted for a higher frequency of facial fractures (88.8%). Mandible was the commonest bone to be fractured among all the facial bones (71.2%). Maxillary central incisors were the most common teeth to be injured (33.8%) and avulsion was the most common type of injury (44.6%). Commonest postoperative complication was plate infection (11%) leading to plate removal. Other injuries associated with facial fractures were rib fractures, head injuries, upper and lower limb fractures, etc., among these rib fractures were seen most frequently (21.6%). This study was performed to compare the different etiologic factors leading to diverse facial fracture patterns. By statistical analysis of this record the authors come to know about the relationship of facial fractures with gender, age, associated comorbidities, etc.

  17. Combined resistance and balance-jumping exercise reduces older women's injurious falls and fractures: 5-year follow-up study.

    Science.gov (United States)

    Karinkanta, Saija; Kannus, Pekka; Uusi-Rasi, Kirsti; Heinonen, Ari; Sievänen, Harri

    2015-09-01

    previously, a randomised controlled exercise intervention study (RCT) showed that combined resistance and balance-jumping training (COMB) improved physical functioning and bone strength. The purpose of this follow-up study was to assess whether this exercise intervention had long-lasting effects in reducing injurious falls and fractures. five-year health-care register-based follow-up study after a 1-year, four-arm RCT. community-dwelling older women in Finland. one hundred and forty-five of the original 149 RCT participants; women aged 70-78 years at the beginning. participants' health-care visits were collected from computerised patient register. An injurious fall was defined as an event in which the subject contacted the health-care professionals or was taken to a hospital, due to a fall. The rate of injured fallers was assessed by Cox proportional hazards model (hazard ratio, HR), and the rate of injurious falls and fractures by Poisson regression (risk ratio, RR). eighty-one injurious falls including 26 fractures occurred during the follow-up. The rate of injured fallers was 62% lower in COMB group compared with the controls (HR 0.38, 95% CI 0.17 to 0.85). In addition, COMB group had 51% less injurious falls (RR 0.49, 95% CI 0.25 to 0.98) and 74% less fractures (RR 0.26, 95% CI 0.07 to 0.97). home-dwelling older women who participated in a 12-month intensive multi-component exercise training showed a reduced incidence for injurious falls during 5-year post-intervention period. Reduction in fractures was also evident. These long-term effects need to be confirmed in future studies. © The Author 2015. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Comparison of fracture toughness (K{sub IC}) and strain energy release rate (G) of selected nuclear graphites

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Se-Hwan, E-mail: shchi@kaeri.re.kr

    2016-08-01

    The fracture behaviors of six nuclear graphite grades for a high-temperature gas-cooled reactor (HTGR), which differed in coke particle size and forming method, were characterized based on the ASTM standard graphite fracture toughness test method (ASTM D 7779-11) at room temperature. The G appeared to show good correlation with the fracture surface roughness and the G-Δa curves appeared to describe the fracture process well from crack initiation to failure. Comparison of the local (K{sub IC}) and gross (G{sub IC}, G-Δa) fracture parameters showed that the resistance to crack initiation and propagation was higher in the extruded or vibration molded medium particle size grades (PCEA, NBG-17, NBG-18: EVM group) than in the iso-molded fine particle size grades (IG-110, IG-430, NBG-25: IMF group). The ASTM may need to provide a guideline for G-Δa curve analysis. The K{sub IC} appeared to increase with specimen thickness (size).

  19. Quasi-static analysis of elastic behavior for some systems having higher fracture densities.

    Energy Technology Data Exchange (ETDEWEB)

    Berryman, J.G.; Aydin, A.

    2009-10-15

    Elastic behavior of geomechanical systems with interacting (but not intersecting) fractures is treated using generalizations of the Backus and the Schoenberg-Muir methods for analyzing layered systems whose layers are intrinsically anisotropic due to locally aligned fractures. By permitting the axis of symmetry of the locally anisotropic compliance matrix for individual layers to differ from that of the layering direction, we derive analytical formulas for interacting fractured regions with arbitrary orientations to each other. This procedure provides a systematic tool for studying how contiguous, but not yet intersecting, fractured domains interact, and provides a direct (though approximate) means of predicting when and how such interactions lead to more dramatic weakening effects and ultimately to failure of these complicated systems. The method permits decomposition of the system elastic behavior into specific eigenmodes that can all be analyzed, and provides a better understanding about which of these specific modes are expected to be most important to the evolving failure process.

  20. Rib Fracture Diagnosis in the Panscan Era.

    Science.gov (United States)

    Murphy, Charles E; Raja, Ali S; Baumann, Brigitte M; Medak, Anthony J; Langdorf, Mark I; Nishijima, Daniel K; Hendey, Gregory W; Mower, William R; Rodriguez, Robert M

    2017-12-01

    With increased use of chest computed tomography (CT) in trauma evaluation, traditional teachings in regard to rib fracture morbidity and mortality may no longer be accurate. We seek to determine rates of rib fracture observed on chest CT only; admission and mortality of patients with isolated rib fractures, rib fractures observed on CT only, and first or second rib fractures; and first or second rib fracture-associated great vessel injury. We conducted a planned secondary analysis of 2 prospectively enrolled cohorts of the National Emergency X-Radiography Utilization Study chest studies, which evaluated patients with blunt trauma who were older than 14 years and received chest imaging in the emergency department. We defined rib fractures and other thoracic injuries according to CT reports and followed patients through their hospital course to determine outcomes. Of 8,661 patients who had both chest radiograph and chest CT, 2,071 (23.9%) had rib fractures, and rib fractures were observed on chest CT only in 1,368 cases (66.1%). Rib fracture patients had higher admission rates (88.7% versus 45.8%; mean difference 42.9%; 95% confidence interval [CI] 41.4% to 44.4%) and mortality (5.6% versus 2.7%; mean difference 2.9%; 95% CI 1.8% to 4.0%) than patients without rib fracture. The mortality of patients with rib fracture observed on chest CT only was not statistically significantly different from that of patients with fractures also observed on chest radiograph (4.8% versus 5.7%; mean difference -0.9%; 95% CI -3.1% to 1.1%). Patients with first or second rib fractures had significantly higher mortality (7.4% versus 4.1%; mean difference 3.3%; 95% CI 0.2% to 7.1%) and prevalence of concomitant great vessel injury (2.8% versus 0.6%; mean difference 2.2%; 95% CI 0.6% to 4.9%) than patients with fractures of ribs 3 to 12, and the odds ratio of great vessel injury with first or second rib fracture was 4.4 (95% CI 1.8 to 10.4). Under trauma imaging protocols that commonly

  1. Fracture Resistance of 14Cr ODS Steel Exposed to a High Temperature Gas

    Directory of Open Access Journals (Sweden)

    Anna Hojna

    2017-12-01

    Full Text Available This paper studies the impact fracture behavior of the 14%Cr Oxide Dispersion Strengthened (ODS steel (ODM401 after high temperature exposures in helium and air in comparison to the as-received state. A steel bar was produced by mechanical alloying and hot-extrusion at 1150 °C. Further, it was cut into small specimens, which were consequently exposed to air or 99.9% helium in a furnace at 720 °C for 500 h. Impact energy transition curves are shifted towards higher temperatures after the gas exposures. The transition temperatures of the exposed states significantly increase in comparison to the as-received steel by about 40 °C in He and 60 °C in the air. Differences are discussed in terms of microstructure, surface and subsurface Scanning Electron Microscope (SEM and Transmission Electron Microscope (TEM observations. The embrittlement was explained as temperature and environmental effects resulting in a decrease of dislocation level, slight change of the particle composition and interface/grain boundary segregations, which consequently affected the nucleation of voids leading to the ductile fracture.

  2. Is Anesthesia Technique Associated With a Higher Risk of Mortality or Complications Within 90 Days of Surgery for Geriatric Patients With Hip Fractures?

    Science.gov (United States)

    Desai, Vimal; Chan, Priscilla H; Prentice, Heather A; Zohman, Gary L; Diekmann, Glenn R; Maletis, Gregory B; Fasig, Brian H; Diaz, Diana; Chung, Elena; Qiu, Chunyuan

    2018-06-01

    Postoperative mortality and complications after geriatric hip fracture surgery remain high despite efforts to improve perioperative care for these patients. One factor of particular interest is anesthetic technique, but prior studies on this are limited by sample selection, competing risks, and incomplete followup. (1) Among older patients undergoing surgery for hip fracture, does 90-day mortality differ depending on the type of anesthesia received? (2) Do 90-day emergency department returns and hospital readmissions differ based on anesthetic technique after geriatric hip fracture repairs? (3) Do 90-day Agency for Healthcare Research and Quality (AHRQ) outcomes differ according to anesthetic techniques used during hip fracture surgery? We conducted a retrospective study on geriatric patients (65 years or older) with hip fractures between 2009 and 2014 using the Kaiser Permanente Hip Fracture Registry. A total of 1995 (11%) of the surgically treated patients with hip fracture were excluded as a result of missing anesthesia information. The final study sample consisted of 16,695 patients. Of these, 2027 (12%) died and 98 (< 1%) terminated membership during followup, which were handled as competing events and censoring events, respectively. Ninety-day mortality, emergency department returns, hospital readmission, deep vein thrombosis (DVT) or pulmonary embolism (PE), myocardial infarction (MI), and pneumonia were evaluated using multivariable competing risk proportional subdistribution hazard regression according to type of anesthesia technique: general anesthesia, regional anesthesia, or conversion from regional to general. Of the 16,695 patients, 58% (N = 9629) received general anesthesia, 40% (N = 6597) received regional anesthesia, and 2.8% (N = 469) patients were converted from regional to general. Compared with regional anesthesia, patients treated with general anesthesia had a higher likelihood of overall 90-day mortality (hazard ratio [HR], 1.22; 95

  3. Ductile-reinforcement toughening in γ-TiAl intermetallic-matrix composites: Effects on fracture toughness and fatigue-crack propagation resistance

    International Nuclear Information System (INIS)

    Venkateswara Rao, K.T.; Ritchie, R.O.; Odette, G.R.

    1994-01-01

    The influence of the type, volume fraction, thickness and orientation of ductile phase reinforcements on the room temperature fatigue and fracture resistance of γ-TiAl intermetallic alloys is investigated. Large improvements in toughness compared to monolithic γ-TiAl are observed in both the TiNb- and Nb-reinforced composites under monotonic loading. Toughness increases with increasing ductile phase content, reinforcement thickness and strength; orientation effect are minimal. Crack-growth behavior is characterized by steep resistance curves primarily due to crack trapping/renucleation and extensive crack bridging by the ductile-phase particles. In contrast, under cyclic loading the influence of ductile phases on fatigue resistance is strongly dependent upon reinforcement orientation. Compared to monolithic γ-TiAl, improvements in fatigue-crack growth resistance are observed in TiNb-reinforced composites only in the face (C-L) orientation; crack-growth rates for the edge (C-R) orientation are actually faster in the composite. In comparison, Nb-particle reinforcements offer less toughening under monotonic loading but enhance the fatigue properties compared to TiNb reinforcements under cyclic loading

  4. Comparison of cutout resistance of dynamic condylar screw and proximal femoral nail in reverse oblique trochanteric fractures: A biomechanical study

    Directory of Open Access Journals (Sweden)

    Gursimrat Singh Cheema

    2012-01-01

    Results: The bending moment of the PFN group was approximately 50% less than that of the DCS group (P<0.0001. The PFN group resisted more number of cycles than the DCS group (P=0.03 and showed lesser number of component failures as compared with the DCS group (P=0.003. Conclusions: The PFN is biomechanically superior to DCS for the fixation of reverse oblique trochanteric fractures of femur.

  5. Geophysical study in waste landfill localized above fractured rocks

    Directory of Open Access Journals (Sweden)

    Ariveltom Cosme da Silva

    2011-08-01

    Full Text Available Geophysical survey is an important method for investigation of contaminated areas used in the characterization of contrasting physical properties in the presence of pollutants. This work applied the geophysical methods of Electrical Resistivity and Self Potential in waste landfill, located in Caçapava do Sul city, RS. The landfill is located over fractured metamorphic rocks. Eight lines of electrical profiling with 288 measures of self potential were done. In addition, 83 measurements of direction and dip of fractures were taken. The application of spontaneous potential method permitted to detect the direction of groundwater flow. The electrical resistivity measurements allowed the identification of low-intensity anomalies associated with the presence of leachate. There is a relationship between anomalous zones and the directions of fractures.

  6. Thermoplastic Micromodel Investigation of Two-Phase Flows in a Fractured Porous Medium

    Directory of Open Access Journals (Sweden)

    Shao-Yiu Hsu

    2017-01-01

    Full Text Available In the past few years, micromodels have become a useful tool for visualizing flow phenomena in porous media with pore structures, e.g., the multifluid dynamics in soils or rocks with fractures in natural geomaterials. Micromodels fabricated using glass or silicon substrates incur high material cost; in particular, the microfabrication-facility cost for making a glass or silicon-based micromold is usually high. This may be an obstacle for researchers investigating the two-phase-flow behavior of porous media. A rigid thermoplastic material is a preferable polymer material for microfluidic models because of its high resistance to infiltration and deformation. In this study, cyclic olefin copolymer (COC was selected as the substrate for the micromodel because of its excellent chemical, optical, and mechanical properties. A delicate micromodel with a complex pore geometry that represents a two-dimensional (2D cross-section profile of a fractured rock in a natural oil or groundwater reservoir was developed for two-phase-flow experiments. Using an optical visualization system, we visualized the flow behavior in the micromodel during the processes of imbibition and drainage. The results show that the flow resistance in the main channel (fracture with a large radius was higher than that in the surrounding area with small pore channels when the injection or extraction rates were low. When we increased the flow rates, the extraction efficiency of the water and oil in the mainstream channel (fracture did not increase monotonically because of the complex two-phase-flow dynamics. These findings provide a new mechanism of residual trapping in porous media.

  7. The fracture behaviour of dental enamel

    OpenAIRE

    Bechtle, Sabine; Habelitz, Stefan; Klocke, Arndt; Fett, Theo; Schneider, Gerold A.

    2009-01-01

    Abstract Enamel is the hardest tissue in the human body covering the crowns of teeth. Whereas the underlying dental material dentin is very well characterised in terms of mechanical and fracture properties, available data for enamel are quite limited and are apart from the most recent investigation mainly based on indentation studies. Within the current study, stable crack-growth experiments in bovine enamel have been performed, to measure fracture resistance curves for enamel. Single edge...

  8. Investigation of the local fracture toughness and the elastic-plastic fracture behavior of NiAl and tungsten by means of micro-cantilever tests

    International Nuclear Information System (INIS)

    Ast, Johannes

    2016-01-01

    The objective of this work was to get an improved understanding of the size dependence of the fracture toughness. For this purpose notched micro-cantilevers were fabricated ranging in dimensions from the submicron regime up to some tens of microns by means of a focused ion beam. B2-NiAl and tungsten were chosen as model materials as their brittle to ductile transition temperatures are well above room temperature. In that way, fracture processes accompanied by limited plastic deformation around the crack tip could be studied at the micro scale. For this size regime, new methods to describe the local elastic-plastic fracture behavior and to measure the fracture toughness were elaborated. Particular focus was set on the J-integral concept which was adapted to the micro scale to derive crack growth from stiffness measurements. This allowed a precise analysis of the transition from crack tip blunting to stable crack growth which is necessary to accurately measure the fracture toughness. Experiments in single crystalline NiAl showed for the two investigated crack systems, namely the hard and the soft orientation, that the fracture toughness at the micro scale is the same as the one known from macroscopic testing. Thus, size effects were not found for the tested length scale. The addition of little amounts of iron did not affect the fracture toughness considerably. Yet, it influenced the crack growth in those samples and consequently the resistance curve behavior. Concerning experiments in single crystalline tungsten, the fracture toughness showed a clear dependency on sample size. The smallest cantilevers fractured purely by cleavage. Larger samples exhibited stable crack growth along with plastic deformation which was recognizable in SEM-micrographs and quantified by means of EBSD measurements. Just as in macroscopic testing, the investigated crack system {100} demonstrated a dependency on loading rate with higher loading rates leading to a more brittle behavior. This

  9. Methodology to predict the initiation of multiple transverse fractures from horizontal wellbores

    Energy Technology Data Exchange (ETDEWEB)

    Crosby, D. G.; Yang, Z.; Rahman, S. S. [Univ. of New South Wales (Australia)

    2001-10-01

    The criterion based on Drucker and Prager which is designed to predict the pressure required to initiate secondary multiple transverse fractures in close proximity to primary fractures is discussed. Results based on this criterion compare favorably with those measured during a series of laboratory-scale hydraulic fracture interaction tests. It is concluded that the multiple fracture criterion and laboratory results demonstrate that transversely fractured horizontal wellbores have a limited capacity to resist the initiation of multiple fractures from adjacent perforations, or intersecting induced and natural fractures. 23 refs., 1 tab., 9 figs.

  10. Fracture resistance of endodontically treated teeth restored with Zirconia filler containing composite core material and fiber posts.

    Science.gov (United States)

    Jeaidi, Zaid Al

    2016-01-01

    To assess the fracture resistance of endodontically treated teeth with a novel Zirconia (Zr) nano-particle filler containing bulk fill resin composite. Forty-five freshly extracted maxillary central incisors were endodontically treated using conventional step back preparation and warm lateral condensation filling. Post space preparation was performed using drills compatible for fiber posts (Rely X Fiber Post) on all teeth (n=45), and posts were cemented using self etch resin cement (Rely X Unicem). Samples were equally divided into three groups (n=15) based on the type of core materials, ZirconCore (ZC) MulticCore Flow (MC) and Luxacore Dual (LC). All specimens were mounted in acrylic resin and loads were applied (Universal testing machine) at 130° to the long axis of teeth, at a crosshead speed of 0.5 mm/min until failure. The loads and the site at which the failures occurred were recorded. Data obtained was tabulated and analyzed using a statistical program. The means and standard deviations were compared using ANOVA and Multiple comparisons test. The lowest and highest failure loads were shown by groups LC (18.741±3.02) and MC (25.16±3.30) respectively. Group LC (18.741±3.02) showed significantly lower failure loads compared to groups ZC (23.02±4.21) and MC (25.16±3.30) (pcomposite cores was comparable to teeth restored with conventional Zr free bulk fill composites. Zr filled bulk fill composites are recommended for restoration of endodontically treated teeth as they show comparable fracture resistance to conventional composite materials with less catastrophic failures.

  11. Change in fracture risk and fracture pattern after bariatric surgery: nested case-control study.

    Science.gov (United States)

    Rousseau, Catherine; Jean, Sonia; Gamache, Philippe; Lebel, Stéfane; Mac-Way, Fabrice; Biertho, Laurent; Michou, Laëtitia; Gagnon, Claudia

    2016-07-27

     To investigate whether bariatric surgery increases the risk of fracture.  Retrospective nested case-control study.  Patients who underwent bariatric surgery in the province of Quebec, Canada, between 2001 and 2014, selected using healthcare administrative databases.  12 676 patients who underwent bariatric surgery, age and sex matched with 38 028 obese and 126 760 non-obese controls.  Incidence and sites of fracture in patients who had undergone bariatric surgery compared with obese and non-obese controls. Fracture risk was also compared before and after surgery (index date) within each group and by type of surgery from 2006 to 2014. Multivariate conditional Poisson regression models were adjusted for fracture history, number of comorbidities, sociomaterial deprivation, and area of residence.  Before surgery, patients undergoing bariatric surgery (9169 (72.3%) women; mean age 42 (SD 11) years) were more likely to fracture (1326; 10.5%) than were obese (3065; 8.1%) or non-obese (8329; 6.6%) controls. A mean of 4.4 years after surgery, bariatric patients were more susceptible to fracture (514; 4.1%) than were obese (1013; 2.7%) and non-obese (3008; 2.4%) controls. Postoperative adjusted fracture risk was higher in the bariatric group than in the obese (relative risk 1.38, 95% confidence interval 1.23 to 1.55) and non-obese (1.44, 1.29 to 1.59) groups. Before surgery, the risk of distal lower limb fracture was higher, upper limb fracture risk was lower, and risk of clinical spine, hip, femur, or pelvic fractures was similar in the bariatric and obese groups compared with the non-obese group. After surgery, risk of distal lower limb fracture decreased (relative risk 0.66, 0.56 to 0.78), whereas risk of upper limb (1.64, 1.40 to 1.93), clinical spine (1.78, 1.08 to 2.93), pelvic, hip, or femur (2.52, 1.78 to 3.59) fractures increased. The increase in risk of fracture reached significance only for biliopancreatic diversion.  Patients undergoing bariatric

  12. Correlations between fracture toughness and microstructure in 4140 steel. MRL E-113

    Energy Technology Data Exchange (ETDEWEB)

    Odegaard, T K

    1979-06-01

    Correlations between the microstructure of an ultra-high strength steel and material resistance to fracture, as measured by blunt notch Charpy impact tests and sharp crack K/sub IC/ tests, were investigated for a standard 870/sup 0/C/oil and an experimental 1175/sup 0/C/oil austenitizing treatment. The increase in sharp crack toughness with higher temperature austenitizing treatments, for the as-quenched and 200/sup 0/C/oil temper conditions, was rationalized by a fracture criterion based on the notion that for fracture to occur, a critical strain, epsilon/sub f/, must be achieved over some critical distance, delta. The lath colonies were identified as the fracture controlling microstructural unit, and hence, their size was considered to be the critical distance, delta. Toughness in the 300/sup 0/C/l hour and 400/sup 0/C/l hour temper conditions, for which the mechanical data indicated an embrittlement, was clearly controlled by the cementite morphology in conjunction with the prior austenite grain size. Attempts to rationalize toughness in these temper conditions, using a stress-controlled fracture criterion, were unsuccessful and led to physically unreasonable results. In the 500/sup 0/C/l hour temper condition, stable crack growth and periodic ridge patterns were observed. Fracture toughness differences between the 870/sup 0/C and 1175/sup 0/C austenitizing treatments were qualitatively rationalized by the nature of the respective fracture morphologies. Good correspondence between J/sub IC/ and the so-called tearing modulus, T, as indicators of sharp crack fracture toughness, was observed.

  13. Correlations between fracture toughness and microstructure in 4140 steel. MRL E-113

    International Nuclear Information System (INIS)

    Odegaard, T.K.

    1979-06-01

    Correlations between the microstructure of an ultra-high strength steel and material resistance to fracture, as measured by blunt notch Charpy impact tests and sharp crack K/sub IC/ tests, were investigated for a standard 870 0 C/oil and an experimental 1175 0 C/oil austenitizing treatment. The increase in sharp crack toughness with higher temperature austenitizing treatments, for the as-quenched and 200 0 C/oil temper conditions, was rationalized by a fracture criterion based on the notion that for fracture to occur, a critical strain, epsilon/sub f/, must be achieved over some critical distance, delta. The lath colonies were identified as the fracture controlling microstructural unit, and hence, their size was considered to be the critical distance, delta. Toughness in the 300 0 C/l hour and 400 0 C/l hour temper conditions, for which the mechanical data indicated an embrittlement, was clearly controlled by the cementite morphology in conjunction with the prior austenite grain size. Attempts to rationalize toughness in these temper conditions, using a stress-controlled fracture criterion, were unsuccessful and led to physically unreasonable results. In the 500 0 C/l hour temper condition, stable crack growth and periodic ridge patterns were observed. Fracture toughness differences between the 870 0 C and 1175 0 C austenitizing treatments were qualitatively rationalized by the nature of the respective fracture morphologies. Good correspondence between J/sub IC/ and the so-called tearing modulus, T, as indicators of sharp crack fracture toughness, was observed

  14. Cyclic Fatigue Resistance of Reciproc Blue, Reciproc, and WaveOne Gold Reciprocating Instruments.

    Science.gov (United States)

    Keskin, Cangül; Inan, Uğur; Demiral, Murat; Keleş, Ali

    2017-08-01

    The aim of the present study was to compare the cyclic fatigue resistance of Reciproc Blue R25 (VDW, Munich, Germany) with Reciproc R25 (VDW) and WaveOne Gold Primary (Denstply Maillefer, Ballaigues, Switzerland). Fifteen Reciproc Blue R25, 15 Reciproc R25, and 15 WaveOne Gold Primary instruments were collected and tested in a dynamic cyclic fatigue test device, which has an artificial canal with a 60° angle of curvature and a 5-mm radius of curvature. All instruments were operated until fracture occurred, and time to fracture (TF) and the lengths of the fractured fragments were recorded. The mean and standard deviations of TF and fragment length were calculated for each reciprocating system. TF data were subjected to Kruskal-Wallis 1-way analysis of variance and the Dunn test, whereas fractured fragment length data were subjected to 1-way analysis of variance (P  .05). Reciproc Blue R25 instruments had significantly higher cyclic fatigue resistance than WaveOne Gold and Reciproc R25 instruments. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  15. Higher fish intake is associated with a lower risk of hip fractures in Chinese men and women: a matched case-control study.

    Science.gov (United States)

    Fan, Fan; Xue, Wen-Qiong; Wu, Bao-Hua; He, Ming-Guang; Xie, Hai-Li; Ouyang, Wei-Fu; Tu, Su-Lan; Chen, Yu-Ming

    2013-01-01

    Fish is rich in nutrients that are favorable to bone health, but limited data are available regarding the relationship between fish intake and hip fractures. Our study examined the association between habitual fish intake and risk of hip fractures. A case-control study was performed between June 2009 and June 2012 in Guangdong Province, China. Five hundred and eighty-one hip fracture incident cases, aged 55 to 80 years (mean: 71 years), were enrolled from four hospitals. 1∶1 matched controls by gender and age (±3 years) were also recruited from communities and hospitals. Face-to-face interviews were used to obtain habitual dietary intake and information on various covariates. Univariate conditional logistic regression analyses showed significantly dose-dependent inverse correlations between the risk of hip fractures and the intake of fresh-water fish, sea fish, mollusca, shellfish, and total fish in all of the subjects (p-trend: water fish (p = 0.553). The ORs (95%CI) of hip fractures for the highest (vs. lowest) quartile were 0.80 (0.48-1.31) for fresh-water fish, 0.31 (0.18-0.52) for sea fish, 0.55 (0.34-0.88) for mollusca and shellfish, and 0.47 (0.28-0.79) for total fish, respectively. Stratified and interaction analyses showed that the association was more significant in males than in females (p-interaction = 0.052). Higher intake of seafood is independently associated with lower risk of hip fractures in elderly Chinese. Increasing consumption of sea fish may benefit the prevention of hip fractures in this population.

  16. SUSTENTAÇÃO DE ESMALTE COM IONÔMEROS DE VIDRO E RESINA COMPOSTA: EFEITO NA RESISTÊNCIA À FRATURA DAS CÚSPIDES DE DENTES RESTAURADOS SUPPORTING ENAMEL WITH GLASS IONOMER CEMENT AND COMPOSITE RESIN: EFFECT ON FRACTURE RESISTANCE OF CUSPS OF RESTORED TEETH

    Directory of Open Access Journals (Sweden)

    Angelo Stefano SECCO

    1997-10-01

    Full Text Available Este estudo determinou a resistência e o tipo de fratura do esmalte suportado pelos materiais restauradores ionômeros de vidro convencional e modificado por resina e resina composta, bem como a influência dessa técnica restauradora na resistência das cúspides dos dentes. A remoção da estrutura dental para o preparo de cavidades tipo classe II e a presença de esmalte socavado diminuiram significativamente a resistência das cúspides dos dentes em relação ao dente hígido (p This study determined the resistance to fracture and its pattern for enamel supported with conventional and modified glass ionomer cements, and composite resin restorative materials, as well as the influence of these restorative techniques on cuspal strength of teeth. Removal of dental structure by class II cavity preparations and unsupported enamel had decreased significantly the cuspal strength in relation to healthy teeth (p < 0.01. Restorative materials used to support enamel reduced the fracture rate of restored cusps, but did not increase the fracture resistance values statistically. All tested groups presented alterations in the fracture pattern

  17. Electrical resistivity tomography investigation of coseismic liquefaction and fracturing at San Carlo, Ferrara Province, Italy

    Directory of Open Access Journals (Sweden)

    Nasser Abu Zeid

    2012-10-01

    Full Text Available Massive surface fracturing and sand ejection took place during the main shock of the May 20, 2012, earthquake (Ml = 5.9 in the Emilia-Romagna region, northern Italy. These phenomena were induced by the liquefaction of water-saturated sand layers, and they damaged several buildings, as well as many roads and sidewalks. They were clustered between the villages of Sant'Agostino and Vigarano Mainarda, located along a paleo-reach of the Reno River [Papathanassiou et al. 2012, this volume]. The subsurface surrounding two major (several decameters long ground ruptures was investigated using electrical resistivity tomographies (ERT, as resistivity is strongly affected by the chemico-physical conditions of loose sediments. Italian regulations require the Municipalities within seismically active areas to develop maps of the potential liquefaction risk. Not all of the territories that are under this kind of risk have been investigated to date. A strong effort to improve this knowledge is therefore needed. Noninvasive geophysical methods can help to fill this gap, as high-resolution techniques are available with good result-to-cost ratios. Among the available methodologies, the most suitable are the methods based on electrical resistivity and permittivity, as they are highly sensitive to the presence of underground water. The ERT method has been carried out successfully across active faults, providing crucial paleoseismological information [Caputo et al. 2003, 2007]. […

  18. Safety of light-water reactor pressure vessels against brittle fracture

    International Nuclear Information System (INIS)

    Brumovsky, M.

    1979-01-01

    The results are surveyed of research by SKODA Trust into brittle failure resistance of materials for WWER type reactor pressure vessels and into pressure vessel operating safety. Conditions are discussed in detail decisive for initiation, propagation and arrest of brittle fracture. The tests on the Cr-Mo-V type steel showed high resistance of the steel to the formation and the propagation of brittle fracture. They also confirmed the high operating reliability and the required service life of the steel. (B.S.)

  19. Risk factors for fractures in the elderly.

    Science.gov (United States)

    Jacqmin-Gadda, H; Fourrier, A; Commenges, D; Dartigues, J F

    1998-07-01

    We report the results of a 5-year prospective cohort study of risk factors for fractures, including drinking fluoridated water, in a cohort of 3,216 men and women aged 65 years and older. We studied risk factors for hip fracture and fractures at other locations separately. We found a higher risk of hip fractures for subjects exposed to fluorine concentrations over 0.11 mg per liter but without a dose-effect relation (odds ratio (OR) = 3.25 for a concentration of 0.11-0.25 mg per liter; OR = 2.43 for > or = 0.25 mg per liter]. For higher thresholds (0.7 and 1 mg per liter), however, the OR was less than 1. We found no association between fluorine and non-hip fractures. Non-hip fractures were associated with polymedication rather than with specific drug use, whereas fracture was associated with polymedication and use of anxiolytic and antidepressive drugs. Subjects drinking spirits every day were more likely to have hip fractures. Tobacco consumption increased the risk for non-hip fractures.

  20. Possible factors for ankle fractures

    Directory of Open Access Journals (Sweden)

    Tabaković Dejan

    2010-01-01

    Full Text Available Background/Aim. Classification of ankle fractures is commonly used for selecting an appropriate treatment and prognosing an outcome of definite management. One of the most used classifications is the Danis-Weber classification. To the best of our knowledge, in the available literature, there are no parameters affecting specific types of ankle fractures according to the Danis-Weber classification. The aim of this study was to analyze the correlation of the following parameters: age, body weight, body mass index (BMI, height, osteoporosis, osteopenia and physical exercises with specific types of ankle fractures using the Danis-Weber classification. Methods. A total of 85 patients grouped by the Danis-Weber classification fracture types were analyzed and the significance of certain parameters for specific types of ankle fractures was established. Results. The proportion of females was significantly higher (p < 0.001 with a significantly higher age (59.9 years, SD ± 14.2 in relation to males (45.1 years, SD ± 12.8 (p < 0.0001. Type A fracture was most frequent in the younger patients (34.2 years, SD ± 8.6, and those with increased physical exercises (p = 0.020. In type B fracture, the risk factor was osteoporosis (p = 0.0180, while in type C fracture, body weight (p = 0.017 and osteoporosis (p = 0.004 were significant parameters. Conclusion. Statistical analysis using the Danis-Weber classification reveals that there are certain parameters suggesting significant risk factors for specific types of ankle fractures.

  1. Higher fetal insulin resistance in Chinese pregnant women with gestational diabetes mellitus and correlation with maternal insulin resistance.

    Science.gov (United States)

    Wang, Qiuwei; Huang, Ruiping; Yu, Bin; Cao, Fang; Wang, Huiyan; Zhang, Ming; Wang, Xinhong; Zhang, Bin; Zhou, Hong; Zhu, Ziqiang

    2013-01-01

    The aim of this study was to determine the effect of gestational diabetes mellitus (GDM) on fetal insulin resistance or β-cell function in Chinese pregnant women with GDM. Maternal fasting blood and venous cord blood samples (reflecting fetal condition) were collected in 65 well-controlled Chinese GDM mothers (only given dietary intervention) and 83 control subjects. The insulin, glucose and proinsulin concentrations of both maternal and cord blood samples were measured, and the homeostasis model assessment of insulin resistance (HOMA-IR) and the proinsulin-to-insulin ratios (an indicator of fetal β-cell function) were calculated in maternal and cord blood respectively. Both maternal and fetal levels of insulin, proinsulin and HOMA-IR but not proinsulin-to-insulin ratios were significantly higher in the GDM group than in the control group (maternal insulin, 24.8 vs. 15.4 µU/mL, P = 0.004, proinsulin, 23.3 vs. 16.2 pmol/L, P = 0.005, and HOMA-IR, 5.5 vs. 3.5, P = 0.041, respectively; fetal: insulin, 15.1 vs. 7.9 µU/mL, Pinsulin ratios was significantly correlated to maternal HOMA-IR (r = 0.307, P = 0.019), in the pregnant women with GDM. Fetal insulin resistance was higher in Chinese pregnant women with GDM than control subjects, and correlated with maternal insulin resistance.

  2. Subcritical fracture propagation in rocks: An examination using the methods of fracture mechanics and non-destructive testing. Ph.D. Thesis

    Science.gov (United States)

    Swanson, P. L.

    1984-01-01

    An experimental investigation of tensile rock fracture is presented with an emphasis on characterizing time dependent crack growth using the methods of fracture mechanics. Subcritical fracture experiments were performed in moist air on glass and five different rock types at crack velocities using the double torsion technique. The experimental results suggest that subcritical fracture resistance in polycrystals is dominated by microstructural effects. Evidence for gross violations of the assumptions of linear elastic fracture mechanics and double torsion theory was found in the tests on rocks. In an effort to obtain a better understanding of the physical breakdown processes associated with rock fracture, a series of nondestructive evaluation tests were performed during subcritical fracture experiments on glass and granite. Comparison of the observed process zone shape with that expected on the basis of a critical normal principal tensile stress criterion shows that the zone is much more elongated in the crack propagation direction than predicted by the continuum based microcracking model alone.

  3. Social inequality and hip fracture

    DEFF Research Database (Denmark)

    Harvey, N. C.; Hansen, L.; Judge, A.

    2015-01-01

    Social inequality appears to be increasing in many countries. We explored whether risk of hip fracture was associated with markers of inequality and whether these relationships changed with time, using data from Danish Health Registries. Methods: All patients 60 years or older with a primary hip...... fracture (ICD10: S720, S721, S722 and S729) were identified from 1 January 1995 to 31 December 2011. Hip fracture patients were matched 1:1 on age, gender and year of fracture to a non-hip fracture control. An individual's education attainment was defined as basic, secondary or higher, and their income...

  4. Increased fracture risk assessed by fracture risk assessment tool in Greek patients with Crohn's disease.

    Science.gov (United States)

    Terzoudis, Sotirios; Zavos, Christos; Damilakis, John; Neratzoulakis, John; Dimitriadi, Daphne Anna; Roussomoustakaki, Maria; Kouroumalis, Elias A; Koutroubakis, Ioannis E

    2013-01-01

    The World Health Organization has recently developed the fracture risk assessment tool (FRAX) based on clinical risk factors and bone mineral density (BMD) for evaluation of the 10-year probability of a hip or a major osteoporotic fracture. The aim of this study was to evaluate the use of the FRAX tool in Greek patients with inflammatory bowel disease (IBD). FRAX scores were applied to 134 IBD patients [68 Crohn's disease (CD); 66 ulcerative colitis (UC)] who underwent dual-energy X-ray absorptiometry scans at the femoral neck and lumbar spine during the period 2007-2012. Calculation of the FRAX scores, with or without BMD, was made through a web-based probability model used to compute individual fracture probabilities according to specific clinical risk factors. The median 10-year probability of a major osteoporotic fracture for IBD patients based on clinical data was 7.1%, and including the BMD was 6.2%. A significant overestimation with the first method was found (P = 0.01). Both scores with and without BMD were significantly higher in CD patients compared with UC patients (P = 0.02 and P = 0.005, respectively). The median 10-year probability of hip fracture based on clinical data was 0.8%, and including the BMD was 0.9%. The score with use of BMD was significantly higher in CD compared with UC patients (P = 0.04). CD patients have significantly higher FRAX scores and possibly fracture risk compared with UC patients. The clinical FRAX score alone seems to overestimate the risk of osteoporotic fracture in Greek IBD patients.

  5. Anatomical Thin Titanium Mesh Plate Structural Optimization for Zygomatic-Maxillary Complex Fracture under Fatigue Testing

    Directory of Open Access Journals (Sweden)

    Yu-Tzu Wang

    2018-01-01

    Full Text Available This study performs a structural optimization of anatomical thin titanium mesh (ATTM plate and optimal designed ATTM plate fabricated using additive manufacturing (AM to verify its stabilization under fatigue testing. Finite element (FE analysis was used to simulate the structural bending resistance of a regular ATTM plate. The Taguchi method was employed to identify the significance of each design factor in controlling the deflection and determine an optimal combination of designed factors. The optimal designed ATTM plate with patient-matched facial contour was fabricated using AM and applied to a ZMC comminuted fracture to evaluate the resting maxillary micromotion/strain under fatigue testing. The Taguchi analysis found that the ATTM plate required a designed internal hole distance to be 0.9 mm, internal hole diameter to be 1 mm, plate thickness to be 0.8 mm, and plate height to be 10 mm. The designed plate thickness factor primarily dominated the bending resistance up to 78% importance. The averaged micromotion (displacement and strain of the maxillary bone showed that ZMC fracture fixation using the miniplate was significantly higher than those using the AM optimal designed ATTM plate. This study concluded that the optimal designed ATTM plate with enough strength to resist the bending effect can be obtained by combining FE and Taguchi analyses. The optimal designed ATTM plate with patient-matched facial contour fabricated using AM provides superior stabilization for ZMC comminuted fractured bone segments.

  6. Stress corrosion cracking resistance of aluminum alloy 7000 series after two-step aging

    Directory of Open Access Journals (Sweden)

    Jegdić Bore V.

    2015-01-01

    Full Text Available The effect of one step-and a new (short two-step aging on the resistance to stress corrosion cracking of an aluminum alloy 7000 series was investigated, using slow strain rate test and fracture mechanics method. Aging level in the tested alloy was evaluated by means of scanning electron microscopy and measurements of electrical resistivity. It was shown that the alloy after the new two-step aging is significantly more resistant to stress corrosion cracking. Values of tensile properties and fracture toughness are similar for both thermal states. Processes that take place at the crack tip have been considered. The effect of the testing solution temperature on the crack growth rate on the plateau was determined. Two values of the apparent activation energy were obtained. These values correspond to different processes that control crack growth rate on the plateau at higher and lower temperatures. [Projekat Ministarstva nauke Republike Srbije, br. TR 34028 i br. TR 34016

  7. Effect of reinforcement with resin composite on fracture strength of structurally compromised roots.

    Science.gov (United States)

    Fukui, Yuji; Komada, Wataru; Yoshida, Keiichi; Otake, Shiho; Okada, Daizo; Miura, Hiroyuki

    2009-09-01

    This study was aimed at evaluating the fracture resistance of structurally compromised roots restored with four different post and core systems. Thirty-two bovine roots were uniformly shaped to simulate human mandibular premolar roots. The roots were divided into four groups based on the type of restoration: cemented cast post and core (Group MC), resin composite build-up (Group CR), resin composite and prefabricated glass fiber post build-up (Group FRC), and thick-layer dual-cured resin composite-reinforced small-diameter tapered cast post and core (Group CRM). After a static loading test, the failure mode and fracture resistance were recorded. Group CRM (719.38+/-196.73 N) exhibited a significantly high fracture resistance compared with the other groups (Group MC: 429.56+/-82.43 N; Group CR: 349.56+/-66.21 N; Group FRC: 398.94+/-112.71 N; pCRM exhibited better mechanical properties for structurally compromised roots with no ferrules, although all types of restorations showed non-restorable fracture modes.

  8. [Trochanteric femoral fractures].

    Science.gov (United States)

    Douša, P; Čech, O; Weissinger, M; Džupa, V

    2013-01-01

    , 31-A2) and intertrochanteric (31-A3) fractures is considered an important approach because of their different behaviour at reduction. Pertrochanteric fractures occurred more frequently (81.5%); the patients' age was higher (80 years on the average) and women outnumbered men at a ratio of 3:1. Intertrochanteric fractures were found in significantly younger patients (average, 72 years), with a women-to-men ratio of 1.3:1. Stable pertrochanteric fractures (31-A1) were preferably indicated for DHS surgery. Unstable pertrochanteric (31-A2) and intertrochanteric (31- A3) fractures were treated with a nail. The patients underwent surgery on the day of injury or the next day. In the case of contraindications to an urgent intervention, surgery was performed after the patient's medical condition had stabilised. The number of complications was largely related to technical errors, such as insufficient reduction or an incorrectly inserted implant. Intertrochanteric fractures were associated with a higher occurrence of complications. No implant can compensate for errors due to surgery. Serious complications can be reduced by the correct assessment of fracture type, the use of an appropriate operative technique and early treatment of potential complications. The necessity of restoring continuity in the medial cortex of the femoral neck (Adams' arch) is the requirement that should be observed. Pseudoarthrosis or varus malalignment in a healed hip should be managed by valgus osteotomy. When the femoral head or the acetabulum is damaged, total hip arthroplasty is indicated. A prerequisite for successful surgical outcome is urgently and correctly performed osteosynthesis allowing for early rehabilitation and mobilisation of the patient.

  9. Influence of the microstructure of WC-Co cemented carbides on the fracture toughness and abrasive wear

    International Nuclear Information System (INIS)

    Zum Gahr, K.H.; Fischer, A.

    1981-01-01

    Fracture toughness and abrasive wear resistance of WC-Co cemented carbides were investigated by using the indentation cracking test (Palmqvist test) and the pin-on-disk method respectively. Size distribution of tungsten carbides and means free path between them were found to be important microstructural parameters related to the mechanical behavior. Results showed that selection of cemented carbides for heavy wear loading is complicated by contradictory influence of microstructural parameters on fracture toughness and abrasion resistance. Knowledge of the relation between microstructure and resistance to fracture or wear is necessary for optimum use of cemented carbides. (orig.) [de

  10. Acute osteomyelitis complicating a simple fracture. A case report.

    Science.gov (United States)

    Drummond-Webb, J J; Schnaid, E

    1983-11-26

    Osteomyelitis complicating a simple fracture is unusual, but the reason for its rarity is unknown. We report on a 9-year-old Black boy who developed acute osteomyelitis after sustaining an acute simple fracture of the femur. The causative role of trauma in acute osteomyelitis is discussed and 'the relative resistance of healthy bone' questioned.

  11. Ductile fracture behaviour of primary heat transport piping material ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Abstract. Design of primary heat transport (PHT) piping of pressurised heavy water reactors (PHWR) has to ensure implementation of leak-before-break con- cepts. In order to be able to do so, the ductile fracture characteristics of PHT piping material have to be quantified. In this paper, the fracture resistance of SA333, Grade.

  12. Evaluation of the resistance to cyclic fatigue among ProTaper Next, ProTaper Universal, and Vortex Blue rotary instruments.

    Science.gov (United States)

    Nguyen, Harrison H; Fong, Hanson; Paranjpe, Avina; Flake, Natasha M; Johnson, James D; Peters, Ove A

    2014-08-01

    The purpose of this study was to compare the fracture resistance to cyclic fatigue of ProTaper Next (PTN; Dentsply Tulsa Dental Specialties, Tulsa, OK), ProTaper Universal (PTU, Dentsply Tulsa Dental Specialties), and Vortex Blue (VB, Dentsply Tulsa Dental Specialties) rotary instruments. Twenty instruments each of PTN X1-X5, PTU S1-F5, and VB 20/04-50/04 were rotated until fracture in a simulated canal of 90° and a 5-mm radius using a custom-made testing platform. The number of cycles to fracture (NCF) was calculated. Weibull analysis was used to predict the maximum number of cycles when 99% of the instrument samples survive. VB 20/04-30/04 had significantly higher NCF than PTU S1-F5 and PTN X1-X5. VB 35/04-45/04 had significantly higher NCF than PTU S2-F5 and PTN X2-X5. PTN X1 had higher NCF than PTU S1-F5. PTN X2 had higher NCF than PTU F2-F5. The Weibull distribution predicted the highest number of cycles at which 99% of instruments survive to be 766 cycles for VB 25/04 and the lowest to be 50 cycles for PTU F2. Under the limitations of this study, VB 20/04-45/04 were more resistant to cyclic fatigue than PTN X2-X5 and PTU S2-F5. PTN X1 and X2 were more resistant to cyclic fatigue than PTU F2-F5. The Weibull distribution appears to be a feasible and potentially clinically relevant model to predict resistance to cyclic fatigue. Copyright © 2014 American Association of Endodontists. All rights reserved.

  13. Effect of copper nanoparticles administered in ovo on the activity of proliferating cells and on the resistance of femoral bones in broiler chickens

    DEFF Research Database (Denmark)

    Mroczek-Sosnowska, Natalia; Lukasiewicz, Monika; Adamek, Dobrochna

    2017-01-01

    The objective of this study was to evaluate bone resistance after in ovo administration of copper nanoparticles (NanoCu) and to determine the number of cells positive for proliferating cell nuclear antigen (PCNA) in the femoral bones of broiler chickens (n = 12 per group). The study demonstrated...... that femoral bones from the NanoCu group were characterised by a higher weight and volume and by significantly greater resistance to fractures compared to the Control group. NanoCu promoted the proliferation of PCNA-positive cells in the long bones of chickens. A significantly higher number of PCNA......-positive cells in the bones of birds in the NanoCu group compared with the Control group (137 and 122, respectively) indicate a stimulatory effect during embryogenesis. Considering the improvement in bone resistance to fractures and the effect of NanoCu on the number of PCNA-positive cells in femoral bones, Nano...

  14. Traumatic Vertebral Fractures and Concomitant Fractures of the Rib in Southwest China, 2001 to 2010

    Science.gov (United States)

    Wang, Hongwei; Zhou, Yue; Ou, Lan; Li, Changqing; Liu, Jun; Xiang, Liangbi

    2015-01-01

    Abstract To our knowledge, the clinical characteristics of traumatic vertebral fractures and concomitant fractures of the rib (TVF-RF) have not been described in previous studies. To investigate the clinical characteristics of patients managed for TVF-RF. A retrospective study of 3142 patients who presented with traumatic vertebral fractures was performed. Two hundred twenty-six patients (7.2%) suffered from TVF-RF. Incidence rate ratios were then calculated with respect to the level of injury to the spine, the ASIA classification of neurological deficits and age. There were 171 male (75.7%) and 55 female (24.3%) patients with a mean age of 43.8 years. The most common mechanisms were falls from high heights in 81 cases and road traffic crashes in 67 cases. Right-sided rib injury occurred in 106 cases, left-sided injury occurred in 76 cases, and bilateral injury occurred in 44 cases. The most frequent location of the rib fractures was from the fourth rib to the ninth rib (70.3%, 510/725). Initial pulmonary complications (IPC) after trauma occurred in 116 cases (51.3%). The mortality rate for the entire group was 1.3% (3/226). The patients with thoracic vertebral fractures and neurological deficits had a higher frequency of multiple rib fractures and IPC than the other patients (P rib fractures, the frequency of IPC and mean intensive care unit (ICU) length of stay also increased. The rates of complications for patients with rib fractures were significantly different from those without rib fractures. We should pay much attention to the patients who presented with thoracic vertebral fractures and neurological deficits for minimizing further complications and mortality in such patients who had a higher frequency of multiple rib fractures and IPC than the other patients. PMID:26554809

  15. Quantifying Discrete Fracture Network Connectivity in Hydraulic Fracturing Stimulation

    Science.gov (United States)

    Urbancic, T.; Ardakani, E. P.; Baig, A.

    2017-12-01

    Hydraulic fracture stimulations generally result in microseismicity that is associated with the activation or extension of pre-existing microfractures and discontinuities. Microseismic events acquired under 3D downhole sensor coverage provide accurate event locations outlining hydraulic fracture growth. Combined with source characteristics, these events provide a high quality input for seismic moment tensor inversion and eventually constructing the representative discrete fracture network (DFN). In this study, we investigate the strain and stress state, identified fracture orientation, and DFN connectivity and performance for example stages in a multistage perf and plug completion in a North American shale play. We use topology, the familiar concept in many areas of structural geology, to further describe the relationships between the activated fractures and their effectiveness in enhancing permeability. We explore how local perturbations of stress state lead to the activation of different fractures sets and how that effects the DFN interaction and complexity. In particular, we observe that a more heterogeneous stress state shows a higher percentage of sub-horizontal fractures or bedding plane slips. Based on topology, the fractures are evenly distributed from the injection point, with decreasing numbers of connections by distance. The dimensionless measure of connection per branch and connection per line are used for quantifying the DFN connectivity. In order to connect the concept of connectivity back to productive volume and stimulation efficiency, the connectivity is compared with the character of deformation in the reservoir as deduced from the collective behavior of microseismicity using robustly determined source parameters.

  16. The fracture behaviour of dental enamel.

    Science.gov (United States)

    Bechtle, Sabine; Habelitz, Stefan; Klocke, Arndt; Fett, Theo; Schneider, Gerold A

    2010-01-01

    Enamel is the hardest tissue in the human body covering the crowns of teeth. Whereas the underlying dental material dentin is very well characterized in terms of mechanical and fracture properties, available data for enamel are quite limited and are apart from the most recent investigation mainly based on indentation studies. Within the current study, stable crack-growth experiments in bovine enamel have been performed, to measure fracture resistance curves for enamel. Single edge notched bending specimens (SENB) prepared out of bovine incisors were tested in 3-point bending and subsequently analysed using optical and environmental scanning electron microscopy. Cracks propagated primarily within the protein-rich rod sheaths and crack propagation occurred under an inclined angle to initial notch direction not only due to enamel rod and hydroxyapatite crystallite orientation but potentially also due to protein shearing. Determined mode I fracture resistance curves ranged from 0.8-1.5 MPa*m(1/2) at the beginning of crack propagation up to 4.4 MPa*m(1/2) at 500 microm crack extension; corresponding mode II values ranged from 0.3 to 1.5 MPa*m(1/2).

  17. Use of fracture mechanics in engineering problems

    Energy Technology Data Exchange (ETDEWEB)

    Carter, C S

    1965-02-26

    If an engineering material containing a crack is subjected to a slowly increasing load, applied so that the crack tends to open, a small zone of plastic yielding develops at the crack tip. This zone increases in size with increasing load, and has the effect of resisting the tendency of the crack to extend. The basic concepts of fracture mechanics are outlined and the significance of crack toughness as measured by KDcU and KD1cU which relate the applied stress and crack size for unstable fracture prior to general yielding is discussed. The methods available for crack-toughness evaluation are indicated, and the mathematical expressions describing KDcU and KD1cU for a variety of geometrical situations are quoted. This approach to the design of fracture- resistant structures has been used in a number of fields in the U.S. and could be of value to the British steam turbine, aerospace, and pressure-vessel industries for design, inspection, and material selection. (64 refs.)

  18. A comparative evaluation of fracture resistance of endodontically treated teeth, with variable marginal ridge thicknesses, restored with composite resin and composite resin reinforced with Ribbond: An in vitro study

    Directory of Open Access Journals (Sweden)

    Vaishali Kalburge

    2013-01-01

    Full Text Available Background: The anatomic shape of maxillary premolars show a tendency towards separation of their cusps during mastication after endodontic treatment. Preservation of the marginal ridge of endodontically treated and restored premolars can act as a strengthening factor and improve the fracture resistance. Objectives: To evaluate the effect of varying thickness of marginal ridge on the fracture resistance of endodontically treated maxillary premolars restored with composite and Ribbond reinforced composites. Materials and Methods: One hundred and twenty, freshly extracted, non carious human mature maxillary premolars were selected for this experimental in vitro study. The teeth were randomly assigned in to twelve groups ( n = 10. Group 1 received no preparation. All the premolars in other groups were root canal treated. In subgroups of 3 and 4, DO cavities were prepared while MOD cavities were prepared for all subgroups of group 2, the dimensions of the proximal boxes were kept uniform. In group 3 and 4 the dimensions of the mesial marginal ridge were measured using a digital Vernier caliper as 2 mm, 1.5 mm, 1 mm and 0.5 mm in the respective subgroups. All samples in groups 2.2 and all the subgroups of 3 were restored with a dentin bonding agent and resin composite. The teeth in group 2.3 and all subgroups of 4 were restored with composite reinforced with Ribbond fibers. The premolars were submitted to axial compression up to failure at 45 degree angle to a palatal cusp in universal testing machine. The mean load necessary to fracture was recorded in Newtons and the data was analysed. Results: There was a highly significant difference between mean values of force required to fracture teeth in group 1 and all subgroups of group 2, 3 and 4 (i.e., P < 0.01 Conclusion: On the basis of static loading, preserving the mesial marginal ridge with thicknesses of mm, 1.5 mm, 1 mm and 0.5 mm, composite restored and Ribbond reinforced composite restored

  19. Higher fish intake is associated with a lower risk of hip fractures in Chinese men and women: a matched case-control study.

    Directory of Open Access Journals (Sweden)

    Fan Fan

    Full Text Available OBJECTIVES: Fish is rich in nutrients that are favorable to bone health, but limited data are available regarding the relationship between fish intake and hip fractures. Our study examined the association between habitual fish intake and risk of hip fractures. METHODS: A case-control study was performed between June 2009 and June 2012 in Guangdong Province, China. Five hundred and eighty-one hip fracture incident cases, aged 55 to 80 years (mean: 71 years, were enrolled from four hospitals. 1∶1 matched controls by gender and age (±3 years were also recruited from communities and hospitals. Face-to-face interviews were used to obtain habitual dietary intake and information on various covariates. RESULTS: Univariate conditional logistic regression analyses showed significantly dose-dependent inverse correlations between the risk of hip fractures and the intake of fresh-water fish, sea fish, mollusca, shellfish, and total fish in all of the subjects (p-trend: <0.001-0.016. After adjusting for covariates, the associations were slightly attenuated but remained significant for all (p-trend: <0.001-0.017 except for fresh-water fish (p = 0.553. The ORs (95%CI of hip fractures for the highest (vs. lowest quartile were 0.80 (0.48-1.31 for fresh-water fish, 0.31 (0.18-0.52 for sea fish, 0.55 (0.34-0.88 for mollusca and shellfish, and 0.47 (0.28-0.79 for total fish, respectively. Stratified and interaction analyses showed that the association was more significant in males than in females (p-interaction = 0.052. CONCLUSION: Higher intake of seafood is independently associated with lower risk of hip fractures in elderly Chinese. Increasing consumption of sea fish may benefit the prevention of hip fractures in this population.

  20. Influence of Nickel Particle Reinforcement on Cyclic Fatigue and Final Fracture Behavior of a Magnesium Alloy Composite

    Directory of Open Access Journals (Sweden)

    Manoj Gupta

    2012-06-01

    Full Text Available The microstructure, tensile properties, cyclic stress amplitude fatigue response and final fracture behavior of a magnesium alloy, denoted as AZ31, discontinuously reinforced with nano-particulates of aluminum oxide and micron size nickel particles is presented and discussed. The tensile properties, high cycle fatigue and final fracture behavior of the discontinuously reinforced magnesium alloy are compared with the unreinforced counterpart (AZ31. The elastic modulus and yield strength of the dual particle reinforced magnesium alloy is marginally higher than of the unreinforced counterpart. However, the tensile strength of the composite is lower than the monolithic counterpart. The ductility quantified by elongation to failure over 0.5 inch (12.7 mm gage length of the test specimen showed minimal difference while the reduction in specimen cross-section area of the composite is higher than that of the monolithic counterpart. At the microscopic level, cyclic fatigue fractures of both the composite and the monolithic alloy clearly revealed features indicative of the occurrence of locally ductile and brittle mechanisms. Over the range of maximum stress and at two different load ratios the cyclic fatigue resistance of the magnesium alloy composite is superior to the monolithic counterpart. The mechanisms responsible for improved cyclic fatigue life and resultant fracture behavior of the composite microstructure are highlighted.

  1. Self-potential observations during hydraulic fracturing

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Jeffrey R.; Glaser, Steven D.

    2007-09-13

    The self-potential (SP) response during hydraulic fracturing of intact Sierra granite was investigated in the laboratory. Excellent correlation of pressure drop and SP suggests that the SP response is created primarily by electrokinetic coupling. For low pressures, the variation of SP with pressure drop is linear, indicating a constant coupling coefficient (Cc) of -200 mV/MPa. However for pressure drops >2 MPa, the magnitude of the Cc increases by 80% in an exponential trend. This increasing Cc is related to increasing permeability at high pore pressures caused by dilatancy of micro-cracks, and is explained by a decrease in the hydraulic tortuosity. Resistivity measurements reveal a decrease of 2% prior to hydraulic fracturing and a decrease of {approx}35% after fracturing. An asymmetric spatial SP response created by injectate diffusion into dilatant zones is observed prior to hydraulic fracturing, and in most cases this SP variation revealed the impending crack geometry seconds before failure. At rupture, injectate rushes into the new fracture area where the zeta potential is different than in the rock porosity, and an anomalous SP spike is observed. After fracturing, the spatial SP distribution reveals the direction of fracture propagation. Finally, during tensile cracking in a point load device with no water flow, a SP spike is observed that is caused by contact electrification. However, the time constant of this event is much less than that for transients observed during hydraulic fracturing, suggesting that SP created solely from material fracture does not contribute to the SP response during hydraulic fracturing.

  2. Toughness degradation evaluation of low alloyed steels by electrical resistivity

    Energy Technology Data Exchange (ETDEWEB)

    Nahm, S H; Yu, K M; Kim, S C [Korea Research Inst. of Standards and Science, Taejon (Korea, Republic of); Kim, A [Department of Mechanical Engineering, Kongju Univ., Kongju, Chungnam (Korea, Republic of)

    1997-09-01

    Remaining life of turbine rotors with a crack can be assessed by the fracture toughness on the aged rotors at service temperature. DC potential drop measurement system was constructed in order to evaluate material toughness nondestructively. Test material was 1Cr-1Mo-0.25V steel used widely for turbine rotor material. Seven kinds of specimen with different degradation levels were prepared according to isothermal aging heat treatment at 630 deg. C. Electrical resistivity of test material was measured at room temperature. It was observed that material toughness and electrical resistivity decreased with the increase of degradation. The relationship between fracture toughness and electrical resistivity was investigated. Fracture toughness of a test material may be determined nondestructively by electrical resistivity. (author). 13 refs, 7 figs.

  3. Basic principles of fracture treatment in children.

    Science.gov (United States)

    Ömeroğlu, Hakan

    2018-04-01

    This review aims to summarize the basic treatment principles of fractures according to their types and general management principles of special conditions including physeal fractures, multiple fractures, open fractures, and pathologic fractures in children. Definition of the fracture is needed for better understanding the injury mechanism, planning a proper treatment strategy, and estimating the prognosis. As the healing process is less complicated, remodeling capacity is higher and non-union is rare, the fractures in children are commonly treated by non-surgical methods. Surgical treatment is preferred in children with multiple injuries, in open fractures, in some pathologic fractures, in fractures with coexisting vascular injuries, in fractures which have a history of failed initial conservative treatment and in fractures in which the conservative treatment has no/little value such as femur neck fractures, some physeal fractures, displaced extension and flexion type humerus supracondylar fractures, displaced humerus lateral condyle fractures, femur, tibia and forearm shaft fractures in older children and adolescents and unstable pelvis and acetabulum fractures. Most of the fractures in children can successfully be treated by non-surgical methods.

  4. Evaluation of Fractured Basement Complex Rock Porosity by ...

    African Journals Online (AJOL)

    current resistivity sounding as complementary geophysical technique to Schlumberger vertical electrical sounding in characterizing fractured geologic systems. Previously, Schlumberger vertical electrical sounding was used to collect data.

  5. Fracture behaviour of brittle (glass) matrix composites

    Czech Academy of Sciences Publication Activity Database

    Dlouhý, Ivo; Chlup, Zdeněk; Boccaccini, A. R.

    2005-01-01

    Roč. 482, - (2005), s. 115-122 ISSN 0255-5476. [International Conference on Materials Structure and Micromechanics of Fracture /4./. Brno, 23.06.2004-25.06.2004] R&D Projects: GA AV ČR(CZ) IAA2041003; GA ČR(CZ) GA101/02/0683 Institutional research plan: CEZ:AV0Z2041904 Keywords : Ceramic matrix composites * fracture toughness * toughening effects Subject RIV: JH - Ceramic s, Fire-Resistant Materials and Glass Impact factor: 0.399, year: 2005

  6. Intelligent fracture creation for shale gas development

    KAUST Repository

    Douglas, Craig C.

    2011-05-14

    Shale gas represents a major fraction of the proven reserves of natural gas in the United States and a collection of other countries. Higher gas prices and the need for cleaner fuels provides motivation for commercializing shale gas deposits even though the cost is substantially higher than traditional gas deposits. Recent advances in horizontal drilling and multistage hydraulic fracturing, which dramatically lower costs of developing shale gas fields, are key to renewed interest in shale gas deposits. Hydraulically induced fractures are quite complex in shale gas reservoirs. Massive, multistage, multiple cluster treatments lead to fractures that interact with existing fractures (whether natural or induced earlier). A dynamic approach to the fracturing process so that the resulting network of reservoirs is known during the drilling and fracturing process is economically enticing. The process needs to be automatic and done in faster than real-time in order to be useful to the drilling crews.

  7. Plastic fracture mechanics prediction of fracture instability in a circumferentially cracked pipe in bending--2. Experimental verification on a Type 304 stainless steel pipe

    International Nuclear Information System (INIS)

    Wilkowski, G.M.; Zahoor, A.; Kanninen, M.F.

    1980-01-01

    The possibility of a pipe fracture emanating from a stress corrosion crack in the heat-affected zones of girth-welds in Type 304 stainless steel pipes was investigated. The J-resistance curve--tearing modulus parameter for the prediction of crack initiation, stable growth and fracture instability--was employed. In the actual experiment, the onset of fracture instability occurred beyond maximum load at an average stable crack growth of 16 to 19 mm (0.63 to 0.75-in.) at each tip. 6 refs

  8. Nasal Carriage of 200 Patients with Nasal Bone Fracture in Korea

    Directory of Open Access Journals (Sweden)

    Jun Wook Lee

    2013-09-01

    Full Text Available Background Pathogens in the nasal cavity during nasal surgery could lead to a systemicinfectious condition, such as bacteremia, nosocomial infection, or toxic shock syndrome.However, there is no research about the prevalence of nasal carriage in patients with nasalbone fracture.Methods This was a prospective, double-blind, randomized study about the rate of nasalcarriage in 200 patients with nasal bone fracture in Korea. Nasal secretions were taken fromboth the middle nasal meatus and colonized. All analyses were carried out using SPSS software.Results Pathogens were identified in 178 of the 200 cases. Coagulase-negative staphylococci(CNS were the most cultured bacteria in 127 (66.84% of the 190 total patients after excluding10 cases of contaminated samples, and methicillin-resistant coagulase-negative staphylococci(MRCNS were found in 48 (25.26%. Staphylococcus aureus was the second mostidentified pathogen, found in 36 (18.95%, followed by 7 cases (3.68% of methicillin-resistantStaphylococcus aureus (MRSA. The prevalence rate of MRSA in the females was higher thanthat in the males (RR=4.70; 95% CI, 1.09-20.18, but other demographic factors had no effecton the prevalence rate of MRSA and MRCNS.Conclusions The prevalence rate of these pathogens in patients with nasal bone fracture inKorea was similar to other reports. However, few studies have addressed the prevalence rateof CNS and MRCNS in accordance with risk factors or the change in prevalence according tospecific prophylaxis against infectious complications. Additional research is needed on thepotential connections between clinical factors and microbiological data.

  9. Fracture toughness of Dy123 low porosity bulks at liquid nitrogen temperature

    International Nuclear Information System (INIS)

    Murakami, A.; Otaka, K.; Miura, T.; Iwamoto, A.

    2011-01-01

    Fracture toughness values were measured for Dy123 bulks. Fracture toughness was improved by reducing porosity. Fracture toughness values at 77 K were higher than those at room temperature. Fracture toughness was also improved by Ag addition. In order to evaluate the fracture toughness of DyBa 2 Cu 3 O x (Dy123) low porosity bulks, bending tests of V-notched specimens cut from the bulks were carried out. Fracture toughness evaluations of a conventional Dy123 bulk which had pores were also carried out and effects of elimination of pores on the fracture toughness were investigated. Fracture toughness values at 77 K of the low porosity bulks were higher than those of the porous bulk. These fracture toughness values at 77 K were higher than the values at room temperature. Fracture toughness of the low porosity bulk was improved by Ag addition.

  10. Higher Desolvation Energy Reduces Molecular Recognition in Multi-Drug Resistant HIV-1 Protease

    Directory of Open Access Journals (Sweden)

    Ladislau C. Kovari

    2012-05-01

    Full Text Available Designing HIV-1 protease inhibitors that overcome drug-resistance is still a challenging task. In this study, four clinical isolates of multi-drug resistant HIV-1 proteases that exhibit resistance to all the US FDA-approved HIV-1 protease inhibitors and also reduce the substrate recognition ability were examined. A multi-drug resistant HIV-1 protease isolate, MDR 769, was co-crystallized with the p2/NC substrate and the mutated CA/p2 substrate, CA/p2 P1’F. Both substrates display different levels of molecular recognition by the wild-type and multi-drug resistant HIV-1 protease. From the crystal structures, only limited differences can be identified between the wild-type and multi-drug resistant protease. Therefore, a wild-type HIV-1 protease and four multi-drug resistant HIV-1 proteases in complex with the two peptides were modeled based on the crystal structures and examined during a 10 ns-molecular dynamics simulation. The simulation results reveal that the multi-drug resistant HIV-1 proteases require higher desolvation energy to form complexes with the peptides. This result suggests that the desolvation of the HIV-1 protease active site is an important step of protease-ligand complex formation as well as drug resistance. Therefore, desolvation energy could be considered as a parameter in the evaluation of future HIV-1 protease inhibitor candidates.

  11. Strength and wear resistance of a dental glass-ionomer cement with a novel nanofilled resin coating.

    Science.gov (United States)

    Lohbauer, Ulrich; Krämer, Norbert; Siedschlag, Gustavo; Schubert, Edward W; Lauerer, Brigitte; Müller, Frank A; Petschelt, Anselm; Ebert, Johannes

    2011-04-01

    To evaluate the influence of different resin coating protocols on the fracture strength and wear resistance of a commercial glass-ionomer cement (GIC). A new restorative concept [Equia (GC Europe)] has been introduced as a system application consisting of a condensable GIC (Fuji IX GP Extra) and a novel nanofilled resin coating material (G-Coat Plus). Four-point fracture strength (FS, 2 x 2 x 25 mm, 14-day storage, distilled water, 37 degrees C) were produced and measured from three experimental protocols: no coating GIC (Group 1), GIC coating before water contamination (Group 2), GIC coating after water contamination (Group 3). The strength data were analyzed using Weibull statistics. Three-body wear resistance (Group 1 vs. Group 2) was measured after each 10,000 wear cycles up to a total of 200,000 cycles using the ACTA method. GIC microstructure and interfaces between GIC and coating materials were investigated under SEM and CLSM. The highest FS of 26.1 MPa and the most homogenous behavior (m = 7.7) has been observed in Group 2. The coated and uncoated GIC showed similar wear resistance until 90,000 cycles. After 200,000 wear cycles, the coated version showed significantly higher wear rate (ANOVA, P< 0.05). The coating protocol has been shown to determine the GIC fracture strength. Coating after water contamination and air drying is leading to surface crack formation thus significantly reducing the FS. The resin coating showed a proper sealing of GIC surface porosities and cracks. In terms of wear, the coating did not improve the wear resistance of the underlying cement as similar or higher wear rates have been measured for Group 1 versus Group 2.

  12. Ductile fracture behavior of cast structure containing voids

    Energy Technology Data Exchange (ETDEWEB)

    Gilles, Ph.; Migne, C. [FRAMATOME ANP, 92 - Paris-La-Defence (France); Chapuliot, S. [CEA Saclay, 91 - Gif-sur-Yvette (France). Dept. de Mecanique et de Technologie

    2001-07-01

    In pressurized water reactors, the primary loop contains cast-piping components made of duplex stainless steel. Due to the presence of ferrite, such steels are susceptible to thermal aging embrittlement, which decrease their fracture resistance. The cast process induces shrinkage cavities, therefore all these components are submitted to liquid penetrant examination and all surface defects are repaired. EDF, CEA and Framatome have conducted experimental and analytical analysis of fatigue and fracture behavior of aged cast stainless steel structures containing shrinkage cavities. The present study considers only ductile tearing and is based on specimen test results and a fracture mechanics model of the interaction between shrinkage cavities. The experimental results presented here show that large groups of shrinkage cavities have almost no influence on the global behavior of the structure. Only for the specimen with the largest reduction of area, a significant reduction of strength has been registered. Using elementary fracture mechanics models, it has been evidenced that failure mechanism of structures containing shrinkage cavities consists in 3 phases: local initiation, macro-crack formation by coalescence and failure by crack instability or collapse depending if J resistance is low or not. No significant changes in global behavior appear in the first phase. (A.C.)

  13. Ductile fracture behavior of cast structure containing voids

    International Nuclear Information System (INIS)

    Gilles, Ph.; Migne, C.; Chapuliot, S.

    2001-01-01

    In pressurized water reactors, the primary loop contains cast-piping components made of duplex stainless steel. Due to the presence of ferrite, such steels are susceptible to thermal aging embrittlement, which decrease their fracture resistance. The cast process induces shrinkage cavities, therefore all these components are submitted to liquid penetrant examination and all surface defects are repaired. EDF, CEA and Framatome have conducted experimental and analytical analysis of fatigue and fracture behavior of aged cast stainless steel structures containing shrinkage cavities. The present study considers only ductile tearing and is based on specimen test results and a fracture mechanics model of the interaction between shrinkage cavities. The experimental results presented here show that large groups of shrinkage cavities have almost no influence on the global behavior of the structure. Only for the specimen with the largest reduction of area, a significant reduction of strength has been registered. Using elementary fracture mechanics models, it has been evidenced that failure mechanism of structures containing shrinkage cavities consists in 3 phases: local initiation, macro-crack formation by coalescence and failure by crack instability or collapse depending if J resistance is low or not. No significant changes in global behavior appear in the first phase. (A.C.)

  14. Dynamic fracture of high-strength metallic alloys: experiments and modelling

    OpenAIRE

    Pérez Martín, María Jesús

    2017-01-01

    Fracture toughness is a property which describes the ability of a material containing a crack to resist fracture. Such a characteristic is one of the most important properties for describing the failure criteria of materials and may be a function of loading rate and temperature. Therefore, in the case of materials that may be subjected to dynamic loads or extreme conditions, it is crucial to be aware of the evolution of their fracture behaviour with such variables. The main objective of t...

  15. Determination techniques of characteristics of brittle fracture for materials on the CMEA 1-35 problem

    International Nuclear Information System (INIS)

    Makhutov, N.A.; Tananov, A.I.; Koshelev, P.F.; Zatsarinnyj, V.V.

    1981-01-01

    The problems concerning the development and improvement of the investigation techniques and the evaluation of the resistance to brittle fracture of a wide class of materials (the reactor ones, in particular) under different conditions of loading using modern test means are considered in the review. It is reflected in the plan of works on the theme 1-35.3 ''Development of the methods of determination of resistance to brittle fracture of the materials and elements of construct Specialists from CMEA member-countries took an active part in its implementation. The development of the 1-35.3 theme presupposes the creation of scientific bases of calculation methods of the details of machines and elements of constructions according to the criteria of resistance to brittle fracture. The results obtained when using the methods of fracture mechanics are of significant importance in the substantiation of strength and admissible defectiveness of large-size constructions operating under the extremum conditions [ru

  16. Examination of parameters affecting overload fracture behavior of flaw-tip hydrides in Zr-2.5Nb pressure tubes in Candu reactors

    International Nuclear Information System (INIS)

    Cui, J.; Shek, G.K.; Wang, Z.R.

    2007-01-01

    Service-induced flaws in Zr-2.5Nb alloy pressure tubes in Candu (Canada Deuterium Uranium Reactors) nuclear reactors are susceptible to a crack initiation and growth mechanism known as Delayed Hydride Cracking (DHC), which is a repetitive process that involves hydrogen diffusion, hydride precipitation, growth and fracture of a hydride region at the flaw-tip under a constant load. Crack initiation may also occur under another loading condition when the hydride region is subjected to an overload. An overload occurs when the hydride region at the flaw tip is loaded to a stress higher than that at which this region is formed such as when the reactor experiences a transient pressure higher than the normal operating pressure where the hydride region is formed. Flaw disposition requires justification that the hydride region overload will not fracture the hydride region, and initiate DHC. In this work, monotonically increasing load experiments were performed on unirradiated Zr-2.5Nb pressure tube specimens containing simulated debris frets (V-notch) and bearing pad frets (BPF, U-shape notch) to examine overload fracture behavior of flaw-tip hydrides formed under hydride ratcheting conditions. Hydride cracking in the overload tests was detected by the acoustic emission technique and confirmed by post-test metallurgical examination. Test results indicate that the resistance to overload fracture is affected by a number of parameters including hydride formation stress, flaw shape (V-notch vs. BPF) and flaw radius (0.015 mm vs. 0.1 mm). The notch-tip hydride morphologies were examined by optical microscopy and scanning electron microscopy (SEM) which show that they are affected by the hydride formation conditions, resulting in different overload fracture resistance. Finite element stress analyses were also performed to obtain flaw-tip stress distributions for interpretation of the test results. (authors)

  17. The successful use of transverse hydraulic fractures from horizontal wellbores

    Energy Technology Data Exchange (ETDEWEB)

    Crosby, D. G.; Yang, Z.; Rahman, S. S. [New South Wales Univ., NSW (Australia)

    1998-12-31

    Since a significant proportion of the world`s recoverable hydrocarbon resources exist in reservoirs possessing permeabilities of less than one milli-Darcy (mD), some form of permeability enhancement or stimulation is necessary if the hydrocarbons are to be exploited economically. Multi-stage, transversely fractured horizontal wellbores are shown to have the potential to greatly increase production from low permeability formations. To overcome the problems caused by near-wellbore tortuosity, common to wells with multiple fracturing from the same perforated interval, a criterion was devised which predicts the wellbore pressures to initiate secondary multiple transverse hydraulic fractures in close proximity to primary fractures. The criterion, confirmed by laboratory experiments, demonstrates that transversely fractured horizontal wellbores have limited capacities to resist the initiation of multiple fractures from adjacent perforations. This characteristic can be used in designing hydraulic fracture treatments to establish injection pressure limits or threshold pressures, above which additional multiple fractures will initiate and propagate from the wellbore. 23 refs., 1 tab., 10 figs.

  18. An experimental study on fracture toughness of resistance spot welded galvanized and ungalvanized DP 450 steel sheets used in automotive body

    Directory of Open Access Journals (Sweden)

    Sevim, Ibrahim

    2016-09-01

    Full Text Available The purpose of this study is to determine fracture toughness of Resistance Spot Welded (RSW Dual Phase (DP steels. RSW of galvanized and ungalvanized DP 450 steel sheets was carried out on spot welding machine. Fracture toughness of RSW joints of galvanized and ungalvanized DP 450 steel sheets was calculated from tensile-shear tests. New empirical equations were developed using Least Squares Method (LSM between energy release rate, fracture toughness and critical crack size depending on the relationship between hardness and fracture toughness values. Results indicated that fracture toughness of joints welded by using RSW increased exponentially while the hardness decreased. In addition, fracture toughness and energy release rate of RSW galvanized DP 450 steel sheets were lower compared to RSW ungalvanized DP 450 steel sheets which had approximately the same hardness.El objetivo de este estudio es determinar la tenacidad de fractura de los aceros dual (DP soldados por puntos de resistencia (RSW. En la máquina de soldadura por puntos se realizó la soldadura de láminas de acero DP 450 galvanizado y sin galvanizar. A partir de los ensayos de tracción-cizallamiento, se calculó la tenacidad a la fractura de las uniones del acero DP 450 galvanizado y sin galvanizar. Aplicando el método de mínimos cuadrados (LSM se desarrollaron nuevas ecuaciones empíricas entre el porcentaje de energía liberada, la tenacidad de fractura y el tamaño de grieta crítica en función de la relación entre los valores de tenacidad de fractura y de dureza. Los resultados indicaron que la tenacidad de fractura de las uniones soldadas por RSW aumentó exponencialmente, mientras que la dureza disminuyó. Además, el porcentaje de energía liberada de las láminas de acero DP 450 galvanizadas y soldadas fueron menores que en el caso de las láminas sin galvanizar a valores iguales de dureza.

  19. First spinning cylinder test analysis by using local approach to fracture

    International Nuclear Information System (INIS)

    Eripret, C.; Rousselier, G.

    1993-01-01

    In recent years, several experimental programs on large scale specimens were organized to evaluate capabilities of the fracture mechanics concepts employed in structural integrity assessment of PWR pressure vessels. During the first spinning cylinder test, a geometry effect was experimentally pointed out and exhibited the problem of transferability of toughness data from small scale to large scale specimens. An original analysis of this test, by means of local approach to fracture is presented in this paper. Both compact tension specimen and spinning cylinder fracture behaviour were computed by using a continuum damage mechanics model developed at EDF. The authors confirmed by numerical analysis that the cylinder's resistance to ductile tearing was considerably larger than in small scale fracture mechanics specimens tests, about 50 percent. The final crack growth predicted by the model was close to the experimental value. Discrepancies in J-R curves seemed to be due to an effect of stress triaxiality and plastic zone evolution. The geometry effect inducing differences in resistance to ductile tearing of the material involved in the specimens can be investigated and explained by using local approach to fracture methodology. 14 refs., 9 figs., 2 tabs

  20. Influence of material ductility and crack surface roughness on fracture instability

    International Nuclear Information System (INIS)

    Khezrzadeh, Hamed; Wnuk, Michael P; Yavari, Arash

    2011-01-01

    This paper presents a stability analysis for fractal cracks. First, the Westergaard stress functions are proposed for semi-infinite and finite smooth cracks embedded in the stress fields associated with the corresponding self-affine fractal cracks. These new stress functions satisfy all the required boundary conditions and according to Wnuk and Yavari's (2003 Eng. Fract. Mech. 70 1659-74) embedded crack model they are used to derive the stress and displacement fields generated around a fractal crack. These results are then used in conjunction with the final stretch criterion to study the quasi-static stable crack extension, which in ductile materials precedes the global failure. The material resistance curves are determined by solving certain nonlinear differential equations and then employed in predicting the stress levels at the onset of stable crack growth and at the critical point, where a transition to the catastrophic failure occurs. It is shown that the incorporation of the fractal geometry into the crack model, i.e. accounting for the roughness of the crack surfaces, results in (1) higher threshold levels of the material resistance to crack propagation and (2) higher levels of the critical stresses associated with the onset of catastrophic fracture. While the process of quasi-static stable crack growth (SCG) is viewed as a sequence of local instability states, the terminal instability attained at the end of this process is identified with the global instability. The phenomenon of SCG can be used as an early warning sign in fracture detection and prevention.

  1. Serum vitamin E concentrations among highly functioning hip fracture patients are higher than in nonfracture controls

    OpenAIRE

    D’Adamo, Christopher R.; Shardell, Michelle D.; Hicks, Gregory E.; Orwig, Denise L.; Hochberg, Marc C.; Semba, Richard D.; Yu-Yahiro, Janet A.; Ferrucci, Luigi; Magaziner, Jay S.; Miller, Ram R.

    2011-01-01

    Malnutrition after hip fracture is common and associated with poor outcomes and protracted recovery. Low concentrations of vitamin E have been associated with incident decline in physical function among older adults and may, therefore, be particularly important to functionally compromised patients hip fracture patients. Serum concentrations of α-tocopherol and γ-tocopherol, the 2 major forms of vitamin E, were assessed in 148 female hip fracture patients 65 years or older from the Baltimore H...

  2. Employing Eigenvalue Ratios to Generate Prior Fracture-like Features for Stochastic Hydrogeophysical Characterization of a Fractured Aquifer System

    Science.gov (United States)

    Brewster, J.; Oware, E. K.

    2017-12-01

    2D, cross-borehole electrical resistivity tomography (ERT) in a fractured aquifer at the UB Environmental Geophysics Imaging Site, with tomograms validated with gamma and caliper logs obtained from the two ERT wells.

  3. Higher fetal insulin resistance in Chinese pregnant women with gestational diabetes mellitus and correlation with maternal insulin resistance.

    Directory of Open Access Journals (Sweden)

    Qiuwei Wang

    Full Text Available OBJECTIVE: The aim of this study was to determine the effect of gestational diabetes mellitus (GDM on fetal insulin resistance or β-cell function in Chinese pregnant women with GDM. MEASUREMENTS: Maternal fasting blood and venous cord blood samples (reflecting fetal condition were collected in 65 well-controlled Chinese GDM mothers (only given dietary intervention and 83 control subjects. The insulin, glucose and proinsulin concentrations of both maternal and cord blood samples were measured, and the homeostasis model assessment of insulin resistance (HOMA-IR and the proinsulin-to-insulin ratios (an indicator of fetal β-cell function were calculated in maternal and cord blood respectively. RESULTS: Both maternal and fetal levels of insulin, proinsulin and HOMA-IR but not proinsulin-to-insulin ratios were significantly higher in the GDM group than in the control group (maternal insulin, 24.8 vs. 15.4 µU/mL, P = 0.004, proinsulin, 23.3 vs. 16.2 pmol/L, P = 0.005, and HOMA-IR, 5.5 vs. 3.5, P = 0.041, respectively; fetal: insulin, 15.1 vs. 7.9 µU/mL, P<0.001, proinsulin, 25.8 vs. 15.1 pmol/L, P = 0.015, and HOMA-IR, 2.8 vs. 1.4, P = 0.017, respectively. Fetal HOMA-IR but not proinsulin-to-insulin ratios was significantly correlated to maternal HOMA-IR (r = 0.307, P = 0.019, in the pregnant women with GDM. CONCLUSIONS: Fetal insulin resistance was higher in Chinese pregnant women with GDM than control subjects, and correlated with maternal insulin resistance.

  4. Effects of electropolishing surface treatment on the cyclic fatigue resistance of BioRace nickel-titanium rotary instruments.

    Science.gov (United States)

    Lopes, Hélio P; Elias, Carlos N; Vieira, Victor T L; Moreira, Edson J L; Marques, Raquel V L; de Oliveira, Julio C Machado; Debelian, Gilberto; Siqueira, José F

    2010-10-01

    This study evaluated the influence of electropolishing surface treatment on the number of cycles to fracture of BioRace rotary nickel-titanium endodontic instruments. BioRace size BR5C instruments with or without electropolishing surface treatment were used in an artificial curved canal under rotational speed of 300 rpm until fracture. Fractured surfaces and the helical shafts of fractured instruments were analyzed by scanning electron microscopy (SEM). Polished instruments displayed a significantly higher number of cycles to fracture when compared with nonpolished instruments (P ductile morphologic characteristics. Evaluation of the separated fragments after cyclic fatigue testing showed the presence of microcracks near the fracture surface. Polished instruments exhibited fine cracks that assumed an irregular path (zigzag crack pattern), whereas nonpolished instruments showed cracks running along the machining grooves. Electropolishing surface treatment of BioRace endodontic instruments significantly increased the cyclic fatigue resistance. Copyright © 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. Fracture Resistance Force of Primary Molar Crowns Milled from ...

    African Journals Online (AJOL)

    2018-04-04

    Apr 4, 2018 ... molar stainless steel crown (SSC) and stored in water at 37°C for 30 days. The crowns were seated on Cr‑Co ... model) or chairside (in‑office system model) CAD/ ..... crowns, deformation may be observed instead of fracture.

  6. Poverty is a risk factor for osteoporotic fractures.

    Science.gov (United States)

    Navarro, M C; Sosa, M; Saavedra, P; Lainez, P; Marrero, M; Torres, M; Medina, C D

    2009-03-01

    This study assesses the possible association between poverty and osteoporosis and/or fragility fractures in a population of postmenopausal women. We found that postmenopausal women with low socioeconomic status had lower values of BMD at the lumbar spine, a higher prevalence of densitometric osteoporosis, and a higher prevalence of total and vertebral fractures. Some lifestyles are related to the presence of osteoporosis and/or fragility fractures, whereas poverty is related to some lifestyles. Because of this, we studied the possible association of poverty with osteoporosis and fractures. This was an observational, cross-sectional study performed in the Canary Islands, Spain. Participants consisted of a total of 1,139 ambulatory postmenopausal women aged 50 years or older with no previous osteoporosis diagnosis and who were enrolled in some epidemiological studies. The prevalence of fractures (vertebral and non-vertebral) and the prevalence of osteoporosis (T-score poverty (annual family income lower than 6,346.80 Euros, in a one-member family, n = 474), were older and heavier and had lower height, lower prevalence of tobacco and alcohol consumption, lower use of HRT and higher use of thiazides. After correcting for age and body mass index (BMI), women in poverty had lower spine BMD values than women with a medium and high socioeconomic status (0.840 g/cm(2) vs. 0.867 g/cm(2), p = 0.005), but there were no statistical differences in femoral neck BMD between groups. The prevalence of osteoporosis was also higher in women in poverty [40.6% vs. 35.6%, (OR 1.35, CI 95%: 1.03; 1.76)] after adjusting by age and BMI. Moreover, 37.8% of women in poverty had a history of at least one fragility fracture compared to 27.7% of women not in poverty (OR: 1.45, CI 95%: 1.11; 1.90). The prevalence of vertebral fractures was also higher in women in poverty 24.7% vs. 13.4%, (OR 2.01, CI 95%: 1.44; 2.81). Postmenopausal women with low socioeconomic status had lower values of BMD at

  7. The loss of activating transcription factor 4 (ATF4) reduces bone toughness and fracture toughness.

    Science.gov (United States)

    Makowski, Alexander J; Uppuganti, Sasidhar; Wadeer, Sandra A; Whitehead, Jack M; Rowland, Barbara J; Granke, Mathilde; Mahadevan-Jansen, Anita; Yang, Xiangli; Nyman, Jeffry S

    2014-05-01

    Even though age-related changes to bone tissue affecting fracture risk are well characterized, only a few matrix-related factors have been identified as important to maintaining fracture resistance. As a gene critical to osteoblast differentiation, activating transcription factor 4 (ATF4) is possibly one of these important factors. To test the hypothesis that the loss of ATF4 affects the fracture resistance of bone beyond bone mass and structure, we harvested bones from Atf4+/+ and Atf4-/- littermates at 8 and 20 weeks of age (n≥9 per group) for bone assessment across several length scales. From whole bone mechanical tests in bending, femurs from Atf4-/- mice were found to be brittle with reduced toughness and fracture toughness compared to femurs from Atf4+/+ mice. However, there were no differences in material strength and in tissue hardness, as determined by nanoindentation, between the genotypes, irrespective of age. Tissue mineral density of the cortex at the point of loading as determined by micro-computed tomography was also not significantly different. However, by analyzing local composition by Raman Spectroscopy (RS), bone tissue of Atf4-/- mice was found to have higher mineral to collagen ratio compared to wild-type tissue, primarily at 20 weeks of age. From RS analysis of intact femurs at 2 orthogonal orientations relative to the polarization axis of the laser, we also found that the organizational-sensitive peak ratio, ν1Phosphate per Amide I, changed to a greater extent upon bone rotation for Atf4-deficient tissue, implying bone matrix organization may contribute to the brittleness phenotype. Target genes of ATF4 activity are not only important to osteoblast differentiation but also in maintaining bone toughness and fracture toughness. Published by Elsevier Inc.

  8. The Loss of Activating Transcription Factor 4 (ATF4) Reduces Bone Toughness and Fracture Toughness

    Science.gov (United States)

    Makowski, Alexander J.; Uppuganti, Sasidhar; Waader, Sandra A.; Whitehead, Jack M.; Rowland, Barbara J.; Granke, Mathilde; Mahadevan-Jansen, Anita; Yang, Xiangli; Nyman, Jeffry S.

    2014-01-01

    Even though age-related changes to bone tissue affecting fracture risk are well characterized, only a few matrix-related factors have been identified as important to maintaining fracture resistance. As a gene critical to osteoblast differentiation, activating transcription factor 4 (ATF4) is possibly one of the seimportant factors. To test the hypothesis that the loss of ATF4 affects the fracture resistance of bone beyond bone mass and structure, we harvested bones from Atf4+/+ and Atf4−/− littermates at 8 and 20 weeks of age (n≥9 per group) for bone assessment across several length scales. From whole bone mechanical tests in bending, femurs from Atf4−/− mice were found to be brittle with reduced toughness and fracture toughness compared to femurs from Atf4+/+ mice. However, there were no differences in material strength and in tissue hardness, as determined by nanoindentation, between the genotypes, irrespective age. Tissue mineral density of the cortex at the point of loading as determined by micro-computed tomography was also not significantly different. However, by analyzing local composition by Raman Spectroscopy (RS), bone tissue of Atf4−/− mice was found to have higher mineral to collagen ratio compared to wild-type tissue, primarily at 20 weeks of age. From RS analysis of intact femurs at 2 orthogonal orientations relative to the polarization axis of the laser, we also found that the organizational-sensitive peak ratio, ν1 Phosphate per Amide I, changed to a greater extent upon bone rotation for Atf4-deficient tissue, implying bone matrix organization may contribute to the brittleness phenotype. Target genes of ATF4 activity are not only important to osteoblast differentiation but also maintaining bone toughness and fracture toughness. PMID:24509412

  9. Surgery for pathological proximal femoral fractures, excluding femoral head and neck fractures: resection vs. stabilisation.

    Science.gov (United States)

    Zacherl, Max; Gruber, Gerald; Glehr, Mathias; Ofner-Kopeinig, Petra; Radl, Roman; Greitbauer, Manfred; Vecsei, Vilmos; Windhager, Reinhard

    2011-10-01

    Pathological femoral head and neck fractures are commonly treated by arthroplasty. Treatment options for the trochanteric region or below are not clearly defined. The purpose of this retrospective, comparative, double-centre study was to analyse survival and influences on outcome according to the surgical technique used to treat pathological proximal femoral fractures, excluding fractures of the femoral head and neck. Fifty-nine patients with 64 fractures were operated up on between 1998 and 2004 in two tertiary referral centres and divided into two groups. One group (S, n = 33) consisted of patients who underwent intramedullary nailing alone, and the other group (R, n = 31) consisted of patients treated by metastatic tissue resection and reconstruction by means of different implants. Median survival was 12.6 months with no difference between groups. Surgical complications were higher in the R group (n = 7) vs. the S group (n = 3), with no statistically significant difference. Patients with surgery-related complications had a higher survival rate (p = 0.049), as did patients with mechanical implant failure (p = 0.01). Survival scoring systems did not correlate with actual survival. Resection of metastases in patients with pathological fractures of the proximal femur, excluding femoral head and neck fractures, has no influence on survival. Patients with long postoperative survival prognosis are at risk of implant-related complications.

  10. Evaluation of tensile strength and fracture toughness of yttria-stabilized zirconia polycrystals with fracture surface analysis

    International Nuclear Information System (INIS)

    Oishi, Manabu; Matsuda, Yukihisa; Noguchi, Kenichi; Masaki, Takaki

    1995-01-01

    The tensile strength of yttria-stabilized tetragonal zirconia polycrystals (Y-TZPs) was measured and the fracture surfaces were analyzed with the scanning electron microscope and X-ray microanalyzer. The fracture origins of the pressureless-sintered samples were voids or inclusions such as Al 2 O 3 , Al 2 O 3 with SiO 2 , and cubic-ZrO 2 , while the fracture origins of the hot isostatically pressed samples were inclusions; no voids were detected at fracture origins. The higher strengths of the hot isostatically pressed samples versus those of the pressureless-sintered samples were consistent with the change in fracture origins. The fracture toughness of the samples calculate from the tensile strength and analysis of the fracture origins was 3.4 to 3.7 MPa ·√m. These values are lower than those measured with the SEPB method. These discrepancies might be caused by the difference in the state of the fracture origin and its neighborhood, such as the size of the fracture origin and interaction between two surfaces in the precrack

  11. A simple model for enamel fracture from margin cracks.

    Science.gov (United States)

    Chai, Herzl; Lee, James J-W; Kwon, Jae-Young; Lucas, Peter W; Lawn, Brian R

    2009-06-01

    We present results of in situ fracture tests on extracted human molar teeth showing failure by margin cracking. The teeth are mounted into an epoxy base and loaded with a rod indenter capped with a Teflon insert, as representative of food modulus. In situ observations of cracks extending longitudinally upward from the cervical margins are recorded in real time with a video camera. The cracks appear above some threshold and grow steadily within the enamel coat toward the occlusal surface in a configuration reminiscent of channel-like cracks in brittle films. Substantially higher loading is required to delaminate the enamel from the dentin, attesting to the resilience of the tooth structure. A simplistic fracture mechanics analysis is applied to determine the critical load relation for traversal of the margin crack along the full length of the side wall. The capacity of any given tooth to resist failure by margin cracking is predicted to increase with greater enamel thickness and cuspal radius. Implications in relation to dentistry and evolutionary biology are briefly considered.

  12. Influence of the supporting die structures on the fracture strength of all-ceramic materials.

    Science.gov (United States)

    Yucel, Munir Tolga; Yondem, Isa; Aykent, Filiz; Eraslan, Oğuz

    2012-08-01

    This study investigated the influence of the elastic modulus of supporting dies on the fracture strengths of all-ceramic materials used in dental crowns. Four different types of supporting die materials (dentin, epoxy resin, brass, and stainless steel) (24 per group) were prepared using a milling machine to simulate a mandibular molar all-ceramic core preparation. A total number of 96 zirconia cores were fabricated using a CAD/CAM system. The specimens were divided into two groups. In the first group, cores were cemented to substructures using a dual-cure resin cement. In the second group, cores were not cemented to the supporting dies. The specimens were loaded using a universal testing machine at a crosshead speed of 0.5 mm/min until fracture occurred. Data were statistically analyzed using two-way analysis of variance and Tukey HSD tests (α = 0.05). The geometric models of cores and supporting die materials were developed using finite element method to obtain the stress distribution of the forces. Cemented groups showed statistically higher fracture strength values than non-cemented groups. While ceramic cores on stainless steel dies showed the highest fracture strength values, ceramic cores on dentin dies showed the lowest fracture strength values among the groups. The elastic modulus of the supporting die structure is a significant factor in determining the fracture resistance of all-ceramic crowns. Using supporting die structures that have a low elastic modulus may be suitable for fracture strength tests, in order to accurately reflect clinical conditions.

  13. Pathologic femur fracture due to a brown tumor in a patient with secondary hyperparathyroidism and vitamin D-resistant rickets.

    Science.gov (United States)

    Wallace, Eric; Day, Matthew; Fadare, Oluwole; Schaefer, Heidi

    2013-02-01

    Vitamin D-resistant rickets is the common clinical outcome of multiple genetic mutations that alter the regulation of phosphorus and vitamin D metabolism, mainly through their effects on fibroblast growth factor 23 (FGF-23). These diseases typically present in childhood with the classic physical examination finding of nutritional rickets, such as genu varum/valgum and rachitic rosary. Treatment, which is aimed at improving severe bone disease with vitamin D and phosphorus supplementation, can cause secondary hyperparathyroidism and/or kidney failure from nephrocalcinosis over the life of the patient. Although FGF-23 has been shown to downregulate parathyroid hormone in vitro, its effect on parathyroid secretion in disease states such as chronic kidney disease and X-linked hypophosphatemic rickets is unclear because elevations in FGF-23 and parathyroid hormone levels characterize both of these disease states. We describe a case of vitamin D-resistant rickets that presented with a femur fracture through a brown tumor. Radiographs show the combination of severe bony abnormalities associated with both long-standing hyperparathyroidism and vitamin D-resistant rickets. Copyright © 2013 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  14. Quality of Postoperative Pain Management After Maxillofacial Fracture Repair.

    Science.gov (United States)

    Peisker, Andre; Meissner, Winfried; Raschke, Gregor F; Fahmy, Mina D; Guentsch, Arndt; Schiller, Juliane; Schultze-Mosgau, Stefan

    2018-05-01

    Effective pain management is an essential component in the perioperative care of surgical patients. However, postoperative pain after maxillofacial fracture repair and its optimal therapy has not been described in detail. In a prospective cohort study, 95 adults rated their pain on the first postoperative day after maxillofacial fracture repair using the questionnaire of the Quality Improvement in Postoperative Pain Management (QUIPS) project. Quality Improvement in Postoperative Pain Management allowed for a standardized assessment of patients' characteristics and pain-related parameters. Overall, the mean maximal pain and pain on activity (numeric rating scales) were significantly higher in patients with mandibular fractures than in patients with midface fractures (P = 0.002 and P = 0.045, respectively). In patients with mandibular fractures, a longer duration of surgery was significantly associated with higher satisfaction with pain intensity (P = 0.015), but was more frequently associated with postoperative vomiting (P = 0.023). A shorter duration of surgery and an absence of preoperative pain counseling in these patients were significantly correlated to desire for more pain medication (P = 0.049 and P = 0.004, respectively). Patients with mandibular fractures that received opioids in the recovery room had significantly higher strain-related pain (P = 0.017). In patients with midface fractures, a longer duration of surgery showed significantly higher levels of decreased mobility (P = 0.003). Patients receiving midazolam for premedication had significantly less minimal pain (P = 0.021). Patients with mandibular fractures seem to have more postoperative pain than patients with midface fractures. Monitoring of postsurgical pain and a procedure-specific pain-treatment protocol should be performed in clinical routine.

  15. Modelling of ductile and cleavage fracture by local approach

    International Nuclear Information System (INIS)

    Samal, M.K.; Dutta, B.K.; Kushwaha, H.S.

    2000-08-01

    This report describes the modelling of ductile and cleavage fracture processes by local approach. It is now well known that the conventional fracture mechanics method based on single parameter criteria is not adequate to model the fracture processes. It is because of the existence of effect of size and geometry of flaw, loading type and rate on the fracture resistance behaviour of any structure. Hence, it is questionable to use same fracture resistance curves as determined from standard tests in the analysis of real life components because of existence of all the above effects. So, there is need to have a method in which the parameters used for the analysis will be true material properties, i.e. independent of geometry and size. One of the solutions to the above problem is the use of local approaches. These approaches have been extensively studied and applied to different materials (including SA33 Gr.6) in this report. Each method has been studied and reported in a separate section. This report has been divided into five sections. Section-I gives a brief review of the fundamentals of fracture process. Section-II deals with modelling of ductile fracture by locally uncoupled type of models. In this section, the critical cavity growth parameters of the different models have been determined for the primary heat transport (PHT) piping material of Indian pressurised heavy water reactor (PHWR). A comparative study has been done among different models. The dependency of the critical parameters on stress triaxiality factor has also been studied. It is observed that Rice and Tracey's model is the most suitable one. But, its parameters are not fully independent of triaxiality factor. For this purpose, a modification to Rice and Tracery's model is suggested in Section-III. Section-IV deals with modelling of ductile fracture process by locally coupled type of models. Section-V deals with the modelling of cleavage fracture process by Beremins model, which is based on Weibulls

  16. Risk factors for trochanteric and femoral neck fracture.

    Science.gov (United States)

    Díaz, A R; Navas, P Z

    The differences between the two main types of fracture of proximal end of the femur, trochanteric and cervical fractures, are still a subject of study, and could be the key to a better understanding of its pathophysiology and prevention. The aim of this study is to determine whether epidemiological differences in the distribution of risk factors associated with hip fracture exist between these two entities. A descriptive cross-sectional study of 428 patients over the age of 65 admitted for trochanteric or cervical fractures in 2015, in which gender, age, previous diagnosis, external causes associated with fracture and place of the event were recorded. There were 220 patients with a cervical fracture (51.4%) and 208 patients with a trochanteric fracture (48.6%). The average age was higher in the trochanteric fracture, observing a constant increase with age only in women with trochanteric fractures. Cervical fracture showed a significant association with cerebrovascular disease (p=0.039) and trochanteric fracture with accidental falls (p=0.047) and presence of 5-9 previous diseases (p=0.014). A regression analysis maintained this association in the case of a cerebrovascular disease (OR 2.6, 95%CI 1.1-6.4) and the presence of 5-9 diseases (OR 1.5, 95%CI 1.1-2.3). Trochanteric fractures are associated with women patients of more advanced ages, 5-9 previous diseases and accidental falls. Cerebrovascular disease shows a higher prevalence in cervical fractures. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Fracture toughness determination in steam generator tubes

    International Nuclear Information System (INIS)

    Bergant M; Yawny, A; Perez Ipina, J

    2012-01-01

    The assessment of the structural integrity of steam generator tubes in nuclear power plants deserved increasing attention in the last years due to the negative impact related to their failures. In this context, elastic plastic fracture mechanics (EPFM) methodology appears as a potential tool for the analysis. The application of EPFM requires, necessarily, knowledge of two aspects, i.e., the driving force estimation in terms of an elastic plastic toughness parameter (e.g., J) and the experimental measurement of the fracture toughness of the material (e.g., the material J-resistance curve). The present work describes the development of a non standardized experimental technique aimed to determine J-resistance curves for steam generator tubes with circumferential through wall cracks. The tubes were made of Incoloy 800 (Ni: 30.0-35.0; Cr: 19.0-23.0; Fe: 35.5 min, % in weight). Due to its austenitic microstructure, this alloy shows very high toughness and is widely used in applications where a good corrosion resistance in aqueous environment or an excellent oxidation resistance in high temperature environment is required. Finally, a procedure for the structural integrity analysis of steam generator tubes with crack-like defects, based on a FAD diagram (Failure Assessment Diagram), is briefly described (author)

  18. Comparison of fracture behavior for low-swelling ferritic and austenitic alloys irradiated in the Fast Flux Test Facility (FFTF) to 180 DPA

    International Nuclear Information System (INIS)

    Huang, F.H.

    1992-02-01

    Fracture toughness testing was conducted to investigate the radiation embrittlement of high-nickel superalloys, modified austenitic steels and ferritic steels. These materials have been experimentally proven to possess excellent resistance to void swelling after high neutron exposures. In addition to swelling resistance, post-irradiation fracture resistance is another important criterion for reactor material selection. By means of fracture mechanics techniques the fracture behavior of those highly irradiated alloys was characterized in terms of irradiation and test conditions. Precipitation-strengthened alloys failed by channel fracture with very low postirradiation ductility. The fracture toughness of titanium-modified austenitic stainless steel D9 deteriorates with increasing fluence to about 100 displacement per atom (dpa), the fluence level at which brittle fracture appears to occur. Ferritic steels such as HT9 are the most promising candidate materials for fast and fusion reactor applications. The upper-shelf fracture toughness of alloy HT9 remained adequate after irradiation to 180 dpa although its ductile- brittle transition temperature (DBTT) shift by low temperature irradiation rendered the material susceptible to brittle fracture at room temperature. Understanding the fracture characteristics under various irradiation and test conditions helps reduce the potential for brittle fracture by permitting appropriate measure to be taken

  19. Nasal Carriage of 200 Patients with Nasal Bone Fracture in Korea

    Directory of Open Access Journals (Sweden)

    Jun Wook Lee

    2013-09-01

    Full Text Available BackgroundPathogens in the nasal cavity during nasal surgery could lead to a systemic infectious condition, such as bacteremia, nosocomial infection, or toxic shock syndrome. However, there is no research about the prevalence of nasal carriage in patients with nasal bone fracture.MethodsThis was a prospective, double-blind, randomized study about the rate of nasal carriage in 200 patients with nasal bone fracture in Korea. Nasal secretions were taken from both the middle nasal meatus and colonized. All analyses were carried out using SPSS software.ResultsPathogens were identified in 178 of the 200 cases. Coagulase-negative staphylococci (CNS were the most cultured bacteria in 127 (66.84% of the 190 total patients after excluding 10 cases of contaminated samples, and methicillin-resistant coagulase-negative staphylococci (MRCNS were found in 48 (25.26%. Staphylococcus aureus was the second most identified pathogen, found in 36 (18.95%, followed by 7 cases (3.68% of methicillin-resistant Staphylococcus aureus (MRSA. The prevalence rate of MRSA in the females was higher than that in the males (RR=4.70; 95% CI, 1.09-20.18, but other demographic factors had no effect on the prevalence rate of MRSA and MRCNS.ConclusionsThe prevalence rate of these pathogens in patients with nasal bone fracture in Korea was similar to other reports. However, few studies have addressed the prevalence rate of CNS and MRCNS in accordance with risk factors or the change in prevalence according to specific prophylaxis against infectious complications. Additional research is needed on the potential connections between clinical factors and microbiological data.

  20. Effects of local mechanical and fracture properties on LBB behavior of a dissimilar metal welded joint in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Du, L.Y.; Wang, G.Z., E-mail: gzwang@ecust.edu.cn; Xuan, F.Z.; Tu, S.T.

    2013-12-15

    Highlights: • Effect of local mechanical and fracture properties on LBB behavior were investigated. • Considering local mechanical properties leads to slightly high LBB curve. • Use of fracture resistance of base or weld will produce non-conservative LBB result. • Local fracture properties of interface region cannot be ignored in LBB analysis. - Abstract: In this paper, three-dimensional finite element models with and without considering local mechanical properties were built for a dissimilar metal welded joint (DMWJ) connected the safe end to pipe-nozzle of a reactor pressure vessel. The inner circumferential surface cracks were postulated at the interface of A508 steel and buttering Alloy52Mb. Based on the elastic–plastic fracture mechanics theory of J-integral, the crack growth stability was analyzed. The effects of the local mechanical and fracture resistance properties on LBB behavior were investigated. The results show that considering local mechanical properties leads to slightly high LBB curve. For the A508/Alloy52Mb interface region cracks in the DMWJ, if the fracture resistance curve of base metal A508 or the buttering Alloy52Mb is used, the non-conservative (unsafe) LBB assessment result will be produced. With increasing the applied bending moment, the degree of un-conservatism in LBB behavior becomes large. Therefore, to obtain accurate LBB assessment results, the local fracture resistance properties of the interface region should be used.

  1. Traumatic Vertebral Fractures and Concomitant Fractures of the Rib in Southwest China, 2001 to 2010: An Observational Study.

    Science.gov (United States)

    Wang, Hongwei; Zhou, Yue; Ou, Lan; Li, Changqing; Liu, Jun; Xiang, Liangbi

    2015-11-01

    To our knowledge, the clinical characteristics of traumatic vertebral fractures and concomitant fractures of the rib (TVF-RF) have not been described in previous studies.To investigate the clinical characteristics of patients managed for TVF-RF. A retrospective study of 3142 patients who presented with traumatic vertebral fractures was performed. Two hundred twenty-six patients (7.2%) suffered from TVF-RF.Incidence rate ratios were then calculated with respect to the level of injury to the spine, the ASIA classification of neurological deficits and age.There were 171 male (75.7%) and 55 female (24.3%) patients with a mean age of 43.8 years. The most common mechanisms were falls from high heights in 81 cases and road traffic crashes in 67 cases. Right-sided rib injury occurred in 106 cases, left-sided injury occurred in 76 cases, and bilateral injury occurred in 44 cases. The most frequent location of the rib fractures was from the fourth rib to the ninth rib (70.3%, 510/725). Initial pulmonary complications (IPC) after trauma occurred in 116 cases (51.3%). The mortality rate for the entire group was 1.3% (3/226). The patients with thoracic vertebral fractures and neurological deficits had a higher frequency of multiple rib fractures and IPC than the other patients (P the increased number of rib fractures, the frequency of IPC and mean intensive care unit (ICU) length of stay also increased.The rates of complications for patients with rib fractures were significantly different from those without rib fractures. We should pay much attention to the patients who presented with thoracic vertebral fractures and neurological deficits for minimizing further complications and mortality in such patients who had a higher frequency of multiple rib fractures and IPC than the other patients.

  2. Fracture toughness of ultra high performance concrete by flexural performance

    Directory of Open Access Journals (Sweden)

    Manolova Emanuela

    2016-01-01

    Full Text Available This paper describes the fracture toughness of the innovative structural material - Ultra High Performance Concrete (UHPC, evaluated by flexural performance. For determination the material behaviour by static loading are used adapted standard test methods for flexural performance of fiber-reinforced concrete (ASTM C 1609 and ASTM C 1018. Fracture toughness is estimated by various deformation parameters derived from the load-deflection curve, obtained by testing simple supported beam under third-point loading, using servo-controlled testing system. This method is used to be estimated the contribution of the embedded fiber-reinforcement into improvement of the fractural behaviour of UHPC by changing the crack-resistant capacity, fracture toughness and energy absorption capacity with various mechanisms. The position of the first crack has been formulated based on P-δ (load- deflection response and P-ε (load - longitudinal deformation in the tensile zone response, which are used for calculation of the two toughness indices I5 and I10. The combination of steel fibres with different dimensions leads to a composite, having at the same time increased crack resistance, first crack formation, ductility and post-peak residual strength.

  3. Cyclic fatigue resistance of XP-endo Shaper compared with different nickel-titanium alloy instruments.

    Science.gov (United States)

    Elnaghy, Amr; Elsaka, Shaymaa

    2018-04-01

    The aims of this study were to assess and compare the resistance to cyclic fatigue of XP-endo Shaper (XPS; FKG Dentaire, La Chaux-de-Fonds, Switzerland) instruments with TRUShape (TRS; Dentsply Tulsa Dental Specialties, Tulsa, OK, USA), HyFlex CM (HCM; Coltene, Cuyahoga Falls, OH, USA), Vortex Blue (VB; Dentsply Tulsa Dental Specialties), and iRace (iR; FKG Dentaire) nickel-titanium rotary instruments at body temperature. Size 30, 0.01 taper of XPS, size 30, 0.04 taper of HCM, VB, iR, and size 30, 0.06 taper of TRS instruments were immersed in saline at 37 ± 1 °C during cyclic fatigue testing. The instruments were tested with 60° angle of curvature and a 3-mm radius of curvature. The number of cycles to failure (NCF) was calculated and the length of the fractured segment was measured. Fractographic examination of the fractured surface was performed using a scanning electron microscope. The data were analyzed statistically using Kruskal-Wallis H test and Mann-Whitney U tests. Statistical significance was set at P ductile fracture of cyclic fatigue failure. XPS instruments exhibited greater cyclic fatigue resistance compared with the other tested instruments. XP-endo Shaper instruments could be used more safely in curved canals due to their higher fatigue resistance.

  4. Development of a plastic fracture methodology. Final report

    International Nuclear Information System (INIS)

    Kanninen, M.F.; Hahn, G.T.; Broek, D.; Stonesifer, R.B.; Marschall, C.W.; Abou-Sayed, I.S.; Zahoor, A.

    1981-03-01

    A number of candidate fracture criteria were investigated to determine the basis for plastic fracture mechanics assessments of nuclear pressure vessels and other components exhibiting fully ductile behavior. The research was comprised of an integrated combination of stable crack growth experiments and elastic-plastic finite element analyses. The results demonstrated that many different fracture criteria can be used as the basis of a resistance curve approach to predicting stable crack growth and fracture instability. All have some disadvantages and none is completely unacceptable. On balance, the best criteria were found to be the J-integral for initiation and limited amounts of stable crack growth and the local crack tip opening angle for extended amounts of stable growth. A combination of the two, which may preserve the advantages of each while reducing their disadvantages, was also suggested by these results

  5. Development of a plastic fracture methodology. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kanninen, M.F.; Hahn, G.T.; Broek, D.; Stonesifer, R.B.; Marschall, C.W.; Abou-Sayed, I.S.; Zahoor, A.

    1981-03-01

    A number of candidate fracture criteria were investigated to determine the basis for plastic fracture mechanics assessments of nuclear pressure vessels and other components exhibiting fully ductile behavior. The research was comprised of an integrated combination of stable crack growth experiments and elastic-plastic finite element analyses. The results demonstrated that many different fracture criteria can be used as the basis of a resistance curve approach to predicting stable crack growth and fracture instability. All have some disadvantages and none is completely unacceptable. On balance, the best criteria were found to be the J-integral for initiation and limited amounts of stable crack growth and the local crack tip opening angle for extended amounts of stable growth. A combination of the two, which may preserve the advantages of each while reducing their disadvantages, was also suggested by these results.

  6. Fracture toughness of stainless steel welds

    International Nuclear Information System (INIS)

    Mills, W.J.

    1985-11-01

    The effects of temperature, composition and weld-process variations on the fracture toughness behavior for Types 308 and 16-8-2 stainless steel (SS) welds were examined using the multiple-specimen J/sub R/-curve procedure. Fracture characteristics were found to be dependent on temperature and weld process but not on filler material. Gas-tungsten-arc (GTA) welds exhibited the highest fracture toughness, a shielded metal-arc (SMA) weld exhibited an intermediate toughness and submerged-arc (SA) welds yielded the lowest toughness. Minimum-expected fracture properties were defined from lower-bound J/sub c/ and tearing modulus values generated here and in previous studies. Fractographic examination revealed that microvoid coalescence was the operative fracture mechanism for all welds. Second phase particles of manganese silicide were found to be detrimental to the ductile fracture behavior because they separated from the matrix during the initial stages of plastic straining. In SA welds, the high density of inclusions resulting from silicon pickup from the flux promoted premature dimple rupture. The weld produced by the SMA process contained substantially less manganese silicide, while GTA welds contained no silicide inclusions. Delta ferrite particles present in all welds were substantially more resistant to local failure than the silicide phase. In welds containing little or no manganese silicide, delta ferrite particles initiated microvoid coalescence but only after extensive plastic straining

  7. Application of borehole geophysics to fracture identification and characterization in low porosity limestones and dolostones

    International Nuclear Information System (INIS)

    Haase, C.S.; King, H.L.

    1986-01-01

    Geophysical logging was conducted in exploratory core holes drilled for geohydrological investigations at three sites used for waste disposal on the US Department of Energy's Oak Ridge Reservation. Geophysical log response was calibrated to borehole geology using the drill core. Subsequently, the logs were used to identify fractures and fractured zones and to characterize the hydrologic activity of such zones. Results of the study were used to identify zones of ground water movement and to select targets for subsequent piezometer and monitoring well installation. Neutron porosity, long- and short-normal resistivity, and density logs exhibit anomalies only adjacent to pervasively fractured zones and rarely exhibit anomalies adjacent to individual fractures, suggesting that such logs have insufficient resolution to detect individual fractures. Spontaneous potential, single point resistance, acoustic velocity, and acoustic variable density logs, however, typically exhibit anomalies adjacent to both individual fractures and fracture zones. Correlation is excellent between fracture density logs prepared from the examination of drill core and fractures identified by the analysis of a suite of geophysical logs that have differing spatial resolution characteristics. Results of the study demonstrate the importance of (1) calibrating geophysical log response to drill core from a site, and (2) running a comprehensive suite of geophysical logs that can evaluate both large- and small-scale rock features. Once geophysical log responses to site-specific geological features have been established, logs provide a means of identifying fracture zones and discriminating between hydrologically active and inactive fracture zones. 9 figs

  8. Cyclic fatigue resistance of 3 different nickel-titanium reciprocating instruments in artificial canals.

    Science.gov (United States)

    Higuera, Oscar; Plotino, Gianluca; Tocci, Luigi; Carrillo, Gabriela; Gambarini, Gianluca; Jaramillo, David E

    2015-06-01

    The purpose of this study was to evaluate the cyclic fatigue resistance of 3 different nickel-titanium reciprocating instruments. A total of 45 nickel-titanium instruments were tested and divided into 3 experimental groups (n = 15): group 1, WaveOne Primary instruments; group 2, Reciproc R25 instruments; and group 3, Twisted File (TF) Adaptive M-L1 instruments. The instruments were then subjected to cyclic fatigue test on a static model consisting of a metal block with a simulated canal with 60° angle of curvature and a 5-mm radius of curvature. WaveOne Primary, Reciproc R25, and TF Adaptive instruments were activated by using their proprietary movements, WaveOne ALL, Reciproc ALL, and TF Adaptive, respectively. All instruments were activated until fracture occurred, and the time to fracture was recorded visually for each file with a 1/100-second chronometer. Mean number of cycles to failure and standard deviations were calculated for each group, and data were statistically analyzed (P fatigue resistance of Reciproc R25 and TF Adaptive M-L1 was significantly higher than that of WaveOne Primary (P = .009 and P = .002, respectively). The results showed no statistically significant difference between TF Adaptive M-L1 and Reciproc R25 (P = .686). Analysis of the fractured portion under scanning electron microscopy indicated that all instruments showed morphologic characteristics of ductile fracture that were due to accumulation of metal fatigue. No statistically significant differences were found between the instruments tested except for WaveOne Primary, which showed the lowest resistance to cyclic fatigue. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. [Torque resistance of three different types of nickel-titanium rotary instruments].

    Science.gov (United States)

    Sun, Wei; Hou, Ben-xiang

    2010-10-01

    To compare torsional fracture of three different types of nickel-titanium rotary instruments ProTaper, Hero642 and Mtwo by making a stimulate models in vitro. Through the establishment of model in vitro, compared the different time with 3 kinds of nickel titanium file in cutting-edge bound occurs, and to observe the section of fractured instruments by scanning electron microscope. The resistence to torque was different from three types of nickel titanium instruments. The time to fracture of Mtwo was significantly longer than ProTaper's and Hero642's, but ProTaper's and Hero642's had no significant difference. Three kinds cross-sectional design were different, a lot of toughness nests were seen in broken surface. Most of them were ductile fracture. Time to fracture was influenced by the quality disfigurement. The resistance to torque of Mtwo was better than ProTaper and Hero642. The lifespan was influenced by the design of cross-section. The quality disfigurement of the files reduced the resistance to flexual fatigue.

  10. Monitoring Induced Fractures with Electrical Measurements using Depth to Surface Resistivity: A Field Case Study

    Science.gov (United States)

    Wilt, M.; Nieuwenhuis, G.; Sun, S.; MacLennan, K.

    2016-12-01

    Electrical methods offer an attractive option to map induced fractures because the recovered anomaly is related to the electrical conductivity of the injected fluid in the open (propped) section of the fracture operation. This is complementary to existing micro-seismic technology, which maps the mechanical effects of the fracturing. In this paper we describe a 2014 field case where a combination of a borehole casing electrode and a surface receiver array was used to monitor hydrofracture fracture creation and growth in an unconventional oil field project. The fracture treatment well was 1 km long and drilled to a depth of 2.2 km. Twelve fracture events were induced in 30 m intervals (stages) in the 1 km well. Within each stage 5 events (clusters) were initiated at 30 m intervals. Several of the fracture stages used a high salinity brine, instead of fresh water, to enhance the electrical signal. The electrical experiment deployed a downhole source in a well parallel to the treatment well and 100 m away. The source consisted of an electrode attached to a wireline cable into which a 0.25 Hz square wave was injected. A 60-station electrical field receiver array was placed above the fracture and extending for several km. Receivers were oriented to measure electrical field parallel with the presumed fracture direction and those perpendicular to it. Active source electrical data were collected continuously during 7 frac stages, 3 of which used brine as the frac fluid over a period of several days. Although the site was quite noisy and the electrical anomaly small we managed to extract a clear frac anomaly using field separation, extensive signal averaging and background noise rejection techniques. Preliminary 3D modeling, where we account for current distribution of the casing electrode and explicitly model multiple thin conductive sheets to represent fracture stages, produces a model consistent with the field measurements and also highlights the sensitivity of the

  11. Epidemiology of hip fracture: Worldwide geographic variation

    Directory of Open Access Journals (Sweden)

    Dinesh K Dhanwal

    2011-01-01

    Full Text Available Osteoporosis is a major health problem, especially in elderly populations, and is associated with fragility fractures at the hip, spine, and wrist. Hip fracture contributes to both morbidity and mortality in the elderly. The demographics of world populations are set to change, with more elderly living in developing countries, and it has been estimated that by 2050 half of hip fractures will occur in Asia. This review conducted using the PubMed database describes the incidence of hip fracture in different regions of the world and discusses the possible causes of this wide geographic variation. The analysis of data from different studies show a wide geographic variation across the world, with higher hip fracture incidence reported from industrialized countries as compared to developing countries. The highest hip fracture rates are seen in North Europe and the US and lowest in Latin America and Africa. Asian countries such as Kuwait, Iran, China, and Hong Kong show intermediate hip fracture rates. There is also a north-south gradient seen in European studies, and more fractures are seen in the north of the US than in the south. The factors responsible of this variation are population demographics (with more elderly living in countries with higher incidence rates and the influence of ethnicity, latitude, and environmental factors. The understanding of this changing geographic variation will help policy makers to develop strategies to reduce the burden of hip fractures in developing countries such as India, which will face the brunt of this problem over the coming decades.

  12. Slower phloem transport in gymnosperm trees can be attributed to higher sieve element resistance.

    Science.gov (United States)

    Liesche, Johannes; Windt, Carel; Bohr, Tomas; Schulz, Alexander; Jensen, Kaare H

    2015-04-01

    In trees, carbohydrates produced in photosynthesizing leaves are transported to roots and other sink organs over distances of up to 100 m inside a specialized transport tissue, the phloem. Angiosperm and gymnosperm trees have a fundamentally different phloem anatomy with respect to cell size, shape and connectivity. Whether these differences have an effect on the physiology of carbohydrate transport, however, is not clear. A meta-analysis of the experimental data on phloem transport speed in trees yielded average speeds of 56 cm h(-1) for angiosperm trees and 22 cm h(-1) for gymnosperm trees. Similar values resulted from theoretical modeling using a simple transport resistance model. Analysis of the model parameters clearly identified sieve element (SE) anatomy as the main factor for the significantly slower carbohydrate transport speed inside the phloem in gymnosperm compared with angiosperm trees. In order to investigate the influence of SE anatomy on the hydraulic resistance, anatomical data on SEs and sieve pores were collected by transmission electron microscopy analysis and from the literature for 18 tree species. Calculations showed that the hydraulic resistance is significantly higher in the gymnosperm than in angiosperm trees. The higher resistance is only partially offset by the considerably longer SEs of gymnosperms. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Fracture mechanical treatment of bridging stresses in ceramics

    International Nuclear Information System (INIS)

    Fett, T.; Munz, D.

    1993-12-01

    Failure of ceramic materials often starts from cracks which can originate at pores, inclusions or can be generated during surface treatment. Fracture occurs when the stress intensity factor of the most serious crack in a component reaches a critical value K lc , the fracture toughness of the material. In case of ideal brittle materials the fracture toughness is independent of the crack extension and, consequently, identical with the stress intensity factor K l0 necessary for the onset of stable crack growth. It is a well-known fact that failure of several ceramics is influenced by an increasing crack-growth resistance curve. Several effects are responsible for this behaviour. Crack-border interactions in the wake of the advancing crack, residual stress fields in the crack region of transformation-toughened ceramics, the generation of a micro-crack zone ahead the crack tip and crack branching. The effect of increasing crack resistance has consequences on many properties of ceramic materials. In this report the authors discuss the some aspects of R-curve behaviour as the representation by stress intensity factors or energies and the influence on the compliance using the bridging stress model. (orig.) [de

  14. Linking Scales in Plastic Deformation and Fracture

    DEFF Research Database (Denmark)

    Martinez-Paneda, Emilio; Niordson, Christian Frithiof; S. Deshpande, Vikram

    2017-01-01

    We investigate crack growth initiation and subsequent resistance in metallic materials by means of an implicit multi-scale approach. Strain gradient plasticity is employed to model the mechanical response of the solid so as to incorporate the role of geometrically necessary dislocations (GNDs......) and accurately capture plasticity at the small scales involved in crack tip deformation. The response ahead of the crack is described by means of a traction-separation law, which is characterized by the cohesive strength and the fracture energy. Results reveal that large gradients of plastic strain accumulatein...... the vicinity of the crack, elevating the dislocation density and the local stress. This stress elevation enhances crack propagation and significantly lowers the steady state fracture toughness with respect to conventional plasticity. Important insight is gained into fracture phenomena that cannot be explained...

  15. Fracture Resistance of Ceramic Laminate Veneers Bonded to Teeth with Class V Composite Fillings after Cyclic Loading

    Directory of Open Access Journals (Sweden)

    Leyla Sadighpour

    2018-01-01

    Full Text Available Purpose. Porcelain laminate veneers (PLVs are sometimes required to be used for teeth with composite fillings. This study examined the fracture strength of PLVs bonded to the teeth restored with different sizes of class V composite fillings. Materials and Methods. Thirty-six maxillary central incisors were divided into three groups (n=12: intact teeth (control and teeth with class V composite fillings of one-third or two-thirds of the crown height (small or large group, resp.. PLVs were made by using IPS e.max and bonded with a resin cement (RelyX Unicem. Fracture resistance (N was measured after cyclic loading (1 × 106 cycles, 1.2 Hz. For statistical analyses, one-way ANOVA and Tukey test were used (α=0.05. Results. There was a significant difference between the mean failure loads of the test groups (P=0.004, with the Tukey-HSD test showing lower failure loads in the large-composite group compared to the control (P=0.02 or small group (P=0.05. The control and small-composite groups achieved comparable results (P>0.05. Conclusions. Failure loads of PLVs bonded to intact teeth and to teeth with small class V composite fillings were not significantly different. However, extensive composite fillings could compromise the bonding of PLVs.

  16. Quantitative x-ray fractographic analysis of fatigue fractures

    International Nuclear Information System (INIS)

    Saprykin, Yu.V.

    1983-01-01

    The study deals with quantitative X-ray fractographic investigation of fatigue fractures of samples with sharp notches tested at various stresses and temperatures with the purpose of establishing a connection between material crack resistance parameters and local plastic instability zones restraining and controlling the crack growth. At fatigue fractures of notched Kh18N9T steel samples tested at +20 and -196 deg C a zone of sharp ring notch effect being analogous to the zone in which crack growth rate is controlled by the microshifting mechanisms is singled out. The size of the notched effect zone in the investigate steel is unambiguosly bound to to the stress amplitude. This provides the possibility to determine the stress value by the results of quantitative fractographic analysis of notched sample fractures. A possibility of determining one of the threshold values of cyclic material fracture toughness by the results of fatigue testing and fractography of notched sample fractures is shown. Correlation between the size of the hsub(s) crack effect zone in the notched sample, delta material yield limit and characteristic of cyclic Ksub(s) fracture toughness has been found. Such correlation widens the possibilities of quantitative diagnostics of fractures by the methods of X-ray fractography

  17. Rib fractures: comparison of associated injuries between pediatric and adult population.

    Science.gov (United States)

    Kessel, Boris; Dagan, Jasmin; Swaid, Forat; Ashkenazi, Itamar; Olsha, Oded; Peleg, Kobi; Givon, Adi; Alfici, Ricardo

    2014-11-01

    Rib fractures are considered a marker of exposure to significant traumatic energy. In children, because of high elasticity of the chest wall, higher energy levels are necessary for ribs to fracture. The purpose of this study was to analyze patterns of associated injuries in children as compared with adults, all of whom presented with rib fractures. A retrospective cohort study involving blunt trauma patients with rib fractures registered in the National Trauma Registry was conducted. Of 6,995 trauma victims who were found to suffer from rib fractures, 328 were children and 6,627 were adults. Isolated rib fractures without associated injuries occurred in 19 children (5.8%) and 731 adults (11%). More adults had 4 or more fractured ribs compared with children (P pneumothorax (P = .006), spleen, and liver injury (P < .001). Mortality rate was 5% in both groups. The incidence of associated head, thoracic, and abdominal solid organ injuries in children was significantly higher than in adults suffering from rib fractures. In spite of a higher Injury Severity Score and incidence of associated injuries, mortality rate was similar. Mortality of rib fracture patients was mostly affected by the presence of extrathoracic injuries. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Epidural Analgesia after Rib Fractures.

    Science.gov (United States)

    Zaw, Andrea A; Murry, Jason; Hoang, David; Chen, Kevin; Louy, Charles; Bloom, Matthew B; Melo, Nicolas; Alban, Rodrigo F; Margulies, Daniel R; Ley, Eric J

    2015-10-01

    Pain associated with rib fractures impairs respiratory function and increases pulmonary morbidity. The purpose of this study was to determine how epidural catheters alter mortality and complications in trauma patients. We performed a retrospective study involving adult blunt trauma patients with moderate-to-severe injuries from January 1, 2004 to December 31, 2013. During the 10-year period, 526 patients met the inclusion criteria; 43/526 (8%) patients had a catheter placed. Mean age of patients with epidural catheter (CATH) was higher compared with patients without epidural catheter (NOCATH) (54 vs 48 years, P = 0.021), Injury Severity Score was similar (26 CATH vs 27 NOCATH, P = 0.84), and CATH had higher mean rib fractures (7.4 vs 4.1, P ribs fractured. The epidural cohort had longer hospital LOS and decreased mortality. In contrast to other studies, DVT rates were increased in patients who received epidural catheters.

  19. Probabilistic fracture mechanics analysis of reactor vessels with low upper-shelf fracture toughness

    International Nuclear Information System (INIS)

    Yoon, K.K.

    1993-01-01

    A class of submerged-arc welds used in fabricating early reactor vessels has relatively high copper contents. Studies have shown that when such vessels are irradiated, the copper contributes to lowering the Charpy upper-shelf energy level. To address this concern, 10CFR50, Appendix G requires a fracture mechanics analysis to demonstrate an adequate margin of safety for continued service. The B and W Owners Group (B and WOG) has been accumulating J-resistance fracture toughness data for these weld metals. Based on a mathematical model derived from this B and WOG data base, the first Appendix G analysis was performed. Another important issue affecting reactor vessel integrity is pressurized thermal shock (PIS) transients. In the early 1980s, probabilistic fracture mechanics analyses were performed on a reactor vessel to determine the probability of failure under postulated accident scenarios. Results of such analyses were used by the Nuclear Regulatory Commission (NRC) to establish the screening criteria for assessing reactor vessel integrity under PTS transient loads. This paper addresses the effect of low upper-shelf toughness on the probability of failure of reactor vessels under PTS loads. Probabilistic fracture mechanics codes were modified to include the low upper-shelf toughness model used in a reference and a series of analyses was performed using plant-specific material conditions and realistic PTS scenarios. The results indicate that low upper-shelf toughness has an insignificant effect on the probability of reactor vessel failures. This is mostly due to PTS transients being susceptible to crack initiation at low temperatures and not affected by upper-shelf fracture toughness

  20. Fracture properties of hydrogenated amorphous silicon carbide thin films

    International Nuclear Information System (INIS)

    Matsuda, Y.; King, S.W.; Bielefeld, J.; Xu, J.; Dauskardt, R.H.

    2012-01-01

    The cohesive fracture properties of hydrogenated amorphous silicon carbide (a-SiC:H) thin films in moist environments are reported. Films with stoichiometric compositions (C/Si ≈ 1) exhibited a decreasing cohesive fracture energy with decreasing film density similar to other silica-based hybrid organic–inorganic films. However, lower density a-SiC:H films with non-stoichiometric compositions (C/Si ≈ 5) exhibited much higher cohesive fracture energy than the films with higher density stoichiometric compositions. One of the non-stoichiometric films exhibited fracture energy (∼9.5 J m −2 ) greater than that of dense silica glasses. The increased fracture energy was due to crack-tip plasticity, as demonstrated by significant pileup formation during nanoindentation and a fracture energy dependence on film thickness. The a-SiC:H films also exhibited a very low sensitivity to moisture-assisted cracking compared with other silica-based hybrid films. A new atomistic fracture model is presented to describe the observed moisture-assisted cracking in terms of the limited Si-O-Si suboxide bond formation that occurs in the films.

  1. Formation evaluation of fractured basement, Cambay Basin, India

    International Nuclear Information System (INIS)

    Gupta, Saurabh Datta; Farooqui, M Y; Chatterjee, Rima

    2012-01-01

    Unconventional reservoirs such as fractured basalts, shale gas and tight sand are currently playing an important role in producing a significant amount of hydrocarbon. The Deccan Trap basaltic rocks form the basement of the Cambay Basin, India, and hold commercially producible hydrocarbon. In this study two wells drilled through fractured basalts are chosen for evaluating the lithology, porosity and oil saturation of the reservoir sections. Well logs, such as gamma ray, high resolution resistivity, litho density, compensated neutron and elemental capture spectroscopy, have been used in cross-plotting techniques for lithology and mineral identification. Formation micro imagery log data have been analysed to quantify the fractures and porosity in the fractured reservoirs for a well in the south Ahmedabad block of the Cambay Basin. The results of the analysis of two wells are presented and discussed and they are found to be in good agreement with geological and production data. (paper)

  2. Influence of Aging Conditions on Fatigue Fracture Behaviour of 6063 Aluminum Alloy

    Directory of Open Access Journals (Sweden)

    Rafiq Ahmed Siddiqui

    2001-12-01

    Full Text Available Aluminum - Magnesium - Silicon (Al-Mg-Si 6063 alloy was heat-treated using under aged, peak aged and overage temperatures. The numbers of cycles required to cause the fatigue fracture, at constant stress, was considered as criteria for the fatigue resistance. Moreover, the fractured surface of the alloy at different aging conditions was evaluated by optical microscopy and the Scanning Electron Microscopy (SEM. The SEM micrographs confirmed the cleavage surfaces with well-defined fatigue striations. It has been observed that the various aging time and temperature of the 6063 Al-alloy, produces different modes of fractures. The most suitable age hardening time and temperature was found to be between 4 to 5 hours and to occur at 460 K. The increase in fatigue fracture property of the alloy due to aging could be attributed to a vacancy assisted diffusion mechanism or due to pinning of dislocations movement by the precipitates produced during aging. However, the decrease in the fatigue resistance, for the over aged alloys, might be due to the coalescence of precipitates into larger grains.

  3. 2016 Accomplishments. Tritium aging studies on stainless steel. Forging process effects on the fracture toughness properties of tritium-precharged stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Morgan, Michael J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-01-01

    Forged austenitic stainless steels are used as the materials of construction for pressure vessels designed to contain tritium at high pressure. These steels are highly resistant to tritium-assisted fracture but their resistance can depend on the details of the forging microstructure. During FY16, the effects of forging strain rate and deformation temperature on the fracture toughness properties of tritium-exposed-and-aged Type 304L stainless steel were studied. Forgings were produced from a single heat of steel using four types of production forging equipment – hydraulic press, mechanical press, screw press, and high-energy-rate forging (HERF). Each machine imparted a different nominal strain rate during the deformation. The objective of the study was to characterize the J-Integral fracture toughness properties as a function of the industrial strain rate and temperature. The second objective was to measure the effects of tritium and decay helium on toughness. Tritium and decay helium effects were measured by thermally precharging the as-forged specimens with tritium gas at 34.5 MPa and 350°C and aging for up to five years at -80°C to build-in decay helium prior to testing. The results of this study show that the fracture toughness properties of the as-forged steels vary with forging strain rate and forging temperature. The effect is largely due to yield strength as the higher-strength forgings had the lower toughness values. For non-charged specimens, fracture toughness properties were improved by forging at 871°C versus 816°C and Screw-Press forgings tended to have lower fracture toughness values than the other forgings. Tritium exposures reduced the fracture toughness values remarkably to fracture toughness values averaging 10-20% of as-forged values. However, forging strain rate and temperature had little or no effect on the fracture toughness after tritium precharging and aging. The result was confirmed by fractography which indicated that fracture modes

  4. 3D electric resistivity tomography (ERT) methodologies applied on selected heavily urbanized areas of the basin of Mexico to detect buried fractures and subsidence problems

    Science.gov (United States)

    Chavez Segura, R. E.; Cifuentes-Nava, G.; Tejero, A.; Hernandez, E.

    2012-12-01

    Urban development in modern cities require of a more integral knowledge of the subsurface, mainly on those areas, where human concentrations increase. Mexico City is one of such an example, where it constitutes one of the largest concentrations of human activities in the world. Most of the urban area is underlain by lacustrine sediments of the former lakes, and confined by important volcanic ranges. Such sediments offer poor foundation conditions for constructive purposes. Therefore, high risk areas have to be identified to prevent accidents and disastrous events. Geophysical techniques can be employed to understand the physical characteristics of the subsurface. Two examples are presented in this investigation. A residential complex named La Concordia is located towards the central portion of the basin that consists of six four storey buildings in an area of 33x80 m2. Finally, a block of small houses (50x50 m2) is found to the southern limit of the basin; close to the Chichinautzin range within the town of Tecomitl. Both zones suffer of strong damage in their structures due to fractures and subsidence within the subsoil. Therefore, Electric Resistivity Tomography (ERT) was carried out to characterize the subsoil beneath these urban complexes. A special array ('horse-shoe' geometry) 'L' employing Wenner-Schlumberger techniques, in addition to equatorial-dipole and minimum-coupling arrays were carried out to fully 'illuminate' beneath the constructions. Computed resistivity models for both examples depicted the buried fracture pattern affecting the urban complexes. Such patterns seem to extend beyond the limits of the surveyed areas, and are probably part of a more complex fracture system. It is very likely that fractures have been produced due to the poorly consolidated clays that cover most of the central part of the Valley of Mexico; the intense water extraction, that form 'voids' in the subsoil causing subsidence effects and finally the existence of regional

  5. Fracture size and transmissivity correlations: Implications for transport simulations in sparse three-dimensional discrete fracture networks following a truncated power law distribution of fracture size

    Science.gov (United States)

    Hyman, J.; Aldrich, G. A.; Viswanathan, H. S.; Makedonska, N.; Karra, S.

    2016-12-01

    We characterize how different fracture size-transmissivity relationships influence flow and transport simulations through sparse three-dimensional discrete fracture networks. Although it is generally accepted that there is a positive correlation between a fracture's size and its transmissivity/aperture, the functional form of that relationship remains a matter of debate. Relationships that assume perfect correlation, semi-correlation, and non-correlation between the two have been proposed. To study the impact that adopting one of these relationships has on transport properties, we generate multiple sparse fracture networks composed of circular fractures whose radii follow a truncated power law distribution. The distribution of transmissivities are selected so that the mean transmissivity of the fracture networks are the same and the distributions of aperture and transmissivity in models that include a stochastic term are also the same.We observe that adopting a correlation between a fracture size and its transmissivity leads to earlier breakthrough times and higher effective permeability when compared to networks where no correlation is used. While fracture network geometry plays the principal role in determining where transport occurs within the network, the relationship between size and transmissivity controls the flow speed. These observations indicate DFN modelers should be aware that breakthrough times and effective permeabilities can be strongly influenced by such a relationship in addition to fracture and network statistics.

  6. Retrospective population cohort study on hip fracture risk associated with zolpidem medication.

    Science.gov (United States)

    Lin, Fang-Yu; Chen, Pei-Chun; Liao, Chun Hui; Hsieh, Yow-Wen; Sung, Fung-Chang

    2014-04-01

    Few studies have evaluated the hip fracture risk for zolpidem users. We assessed the risk for subjects taking zolpidem. Population-based retrospective cohort study using claims data of a universal insurance system. We identified 6,978 patients newly prescribed for zolpidem in 2000-2001 age 18 y and older, and 27,848 nonusers frequency matched with sex, age, and date visiting a clinic. Both cohorts were followed up to the end of 2008 to measure the hip fracture incidence and risk, which considered factors such as sex, age, occupation, days of drug use, and osteoporosis status. The zolpidem users had a 2.23-fold higher hip fracture incidence than nonusers (3.10 versus 1.39 per 1,000 person-y). The risk increased with age for both cohorts. The elderly users had a 21-fold higher incidence than the younger users, or twofold higher than the elderly nonusers. Among 33 patients (20.4%) with hip fracture occurring during presumed medication days, which was accountable for an incidence of 1,083.0 per 1,000 person-y. Those taking the medicine for 8 days or longer had a moderately higher fracture rate than those taking it for less days (6.02 versus 4.48 per 100 person-times) with a ratio of 1.34 (95% confidence interval 0.42-4.56). Subjects with blue collar occupations were at a higher fracture risk. The hip fracture risk of zolpidem users is higher than that of nonusers. Fracture prevention awareness should be disseminated to the users.

  7. Subsurface fracture mapping from geothermal wellbores. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hartenbaum, B.A.; Rawson, G.

    1983-08-01

    To advance the state-of-the-art in Hot Dry Rock technology, and evaluation is made of (1) the use of both electromagnetic and acoustic radar to map far-field fractures, (2) the use of more than twenty different conventional well logging tools to map borehole-fracture intercepts, (3) the use of magnetic dipole ranging to determine the relative positions of the injection well and the production well within the fractured zone, (4) the use of passive microseismic methods to determine the orientation and extent of hydraulic fractures, and (5) the application of signal processing techniques to fracture mapping including tomography, holography, synthetic aperture, image reconstruction, and the relative importance of phase and amplitude information. It is found that according to calculations, VHF backscatter radar has the potential for mapping fractures within a distance of 50 +- 20 meters from the wellbore. A new technique for improving fracture identification is presented. The range of acoustic radar is five to seven times greater than that of VHF radar when compared on the basis of equal resolution, i.e., equal wavelengths. Analyses of extant data indicate that when used synergistically the (1) caliper, (2) resistivity dipmeter, (3) televiewer, (4) television, (5) impression packer, and (6) acoustic transmission are useful for mapping borehole-fracture intercepts. A new model of hydraulic fracturing is presented which indicates that a hydraulic fracture is dynamically unstable; consequently, improvements in locating the crack tip may be possible. The importance of phase in signal processing is stressed and those techniques which employ phase data are emphasized for field use.

  8. Effect of Random Natural Fractures on Hydraulic Fracture Propagation Geometry in Fractured Carbonate Rocks

    Science.gov (United States)

    Liu, Zhiyuan; Wang, Shijie; Zhao, Haiyang; Wang, Lei; Li, Wei; Geng, Yudi; Tao, Shan; Zhang, Guangqing; Chen, Mian

    2018-02-01

    Natural fractures have a significant influence on the propagation geometry of hydraulic fractures in fractured reservoirs. True triaxial volumetric fracturing experiments, in which random natural fractures are created by placing cement blocks of different dimensions in a cuboid mold and filling the mold with additional cement to create the final test specimen, were used to study the factors that influence the hydraulic fracture propagation geometry. These factors include the presence of natural fractures around the wellbore, the dimension and volumetric density of random natural fractures and the horizontal differential stress. The results show that volumetric fractures preferentially formed when natural fractures occurred around the wellbore, the natural fractures are medium to long and have a volumetric density of 6-9%, and the stress difference is less than 11 MPa. The volumetric fracture geometries are mainly major multi-branch fractures with fracture networks or major multi-branch fractures (2-4 fractures). The angles between the major fractures and the maximum horizontal in situ stress are 30°-45°, and fracture networks are located at the intersections of major multi-branch fractures. Short natural fractures rarely led to the formation of fracture networks. Thus, the interaction between hydraulic fractures and short natural fractures has little engineering significance. The conclusions are important for field applications and for gaining a deeper understanding of the formation process of volumetric fractures.

  9. Epidemiology of distal forearm fractures in Oslo, Norway.

    Science.gov (United States)

    Lofthus, C M; Frihagen, F; Meyer, H E; Nordsletten, L; Melhuus, K; Falch, J A

    2008-06-01

    The population of Oslo has the highest incidence of hip fracture reported. The present study shows that the overall incidence of distal forearm fractures in Oslo is higher than in other countries and has not changed significantly when comparing the incidence of 1998/99 with 1979. The population of Oslo has the highest incidence of hip fracture reported. The present study reports the incidence of distal forearm fracture in Oslo and the fracture rates of immigrants. Patients aged > or = 20 years resident in Oslo sustaining a distal forearm fracture in a one-year period in 1998/99 were identified using electronic diagnosis registers, patient protocols, and/or X-ray registers of the clinics in Oslo. Medical records were obtained and the diagnosis verified. The age- and sex-specific incidence rates were calculated and compared with those for 1979. Data on immigrant category and country of origin of the patients were obtained. The age-adjusted fracture rates per 10,000 for the age group > or = 50 years were 109.8 and 25.4 in 1998/99 compared with 108.3 and 23.5 in 1979 for women and men, respectively (n.s.). The relative risk of fracture in Asians was 0.72 (95% CI 0.53-1.00) compared with ethnic Norwegians. The overall incidence of distal forearm fractures in Oslo is higher than in other countries and has not changed significantly when comparing the incidence of 1998/99 with 1979. Furthermore, the present data suggest that Asian immigrants in Oslo have a slightly lower fracture risk than ethnic Norwegians.

  10. Near Wellbore Hydraulic Fracture Propagation from Perforations in Tight Rocks: The Roles of Fracturing Fluid Viscosity and Injection Rate

    Directory of Open Access Journals (Sweden)

    Seyed Hassan Fallahzadeh

    2017-03-01

    Full Text Available Hydraulic fracture initiation and near wellbore propagation is governed by complex failure mechanisms, especially in cased perforated wellbores. Various parameters affect such mechanisms, including fracturing fluid viscosity and injection rate. In this study, three different fracturing fluids with viscosities ranging from 20 to 600 Pa.s were used to investigate the effects of varying fracturing fluid viscosities and fluid injection rates on the fracturing mechanisms. Hydraulic fracturing tests were conducted in cased perforated boreholes made in tight 150 mm synthetic cubic samples. A true tri-axial stress cell was used to simulate real far field stress conditions. In addition, dimensional analyses were performed to correspond the results of lab experiments to field-scale operations. The results indicated that by increasing the fracturing fluid viscosity and injection rate, the fracturing energy increased, and consequently, higher fracturing pressures were observed. However, when the fracturing energy was transferred to a borehole at a faster rate, the fracture initiation angle also increased. This resulted in more curved fracture planes. Accordingly, a new parameter, called fracturing power, was introduced to relate fracture geometry to fluid viscosity and injection rate. Furthermore, it was observed that the presence of casing in the wellbore impacted the stress distribution around the casing in such a way that the fracture propagation deviated from the wellbore vicinity.

  11. Physical Properties of Fractured Porous Media

    Science.gov (United States)

    Mohammed, T. E.; Schmitt, D. R.

    2015-12-01

    The effect of fractures on the physical properties of porous media is of considerable interest to oil and gas exploration as well as enhanced geothermal systems and carbon capture and storage. This work represents an attempt to study the effect fractures have on multiple physical properties of rocks. An experimental technique to make simultaneous electric and ultrasonic measurements on cylindrical core plugs is developed. Aluminum end caps are mounted with ultrasonic transducers to transmit pules along the axis of the cylinder while non-polarizing electrodes are mounted on the sides of the core to make complex conductivity measurements perpendicular to the cylinder axis. Electrical measurements are made by applying a sinusoidal voltage across the measurement circuit that consist of a resister and the sample in series. The magnitude and phase of the signal across the sample is recorded relative to the input signal across a range of frequencies. Synthetic rock analogs are constructed using sintered glass beads with fractures imbedded in them. The fracture location, size and orientation are controlled and each fractured specimen has an unfractured counterpart. Porosity, Permeability, electrical conductivity and ultrasonic velocity measurements are conducted on each sample with the complex electrical conductivities recorded at frequencies from 10hz to 1 Mhz. These measurements allow us to examine the changes induced by these mesoscale fractures on the embedding porous medium. Of particular interest is the effect of fracture orientation on electrical conductivity of the rock. Seismic anisotropy caused by fractures is a well understood phenomenon with many rock physics models dedicated to its understanding. The effect of fractures on electrical conductivity is less well understood with electrical anisotropy scarcely investigated in the literature. None the less, using electrical conductivity to characterize fractures can add an extra constraint to characterization based

  12. Onset of density-driven instabilities in fractured aquifers

    Science.gov (United States)

    Jafari Raad, Seyed Mostafa; Hassanzadeh, Hassan

    2018-04-01

    Linear stability analysis is conducted to study the onset of density-driven convection involved in solubility trapping of C O2 in fractured aquifers. The effect of physical properties of a fracture network on the stability of a diffusive boundary layer in a saturated fractured porous media is investigated using the dual porosity concept. Linear stability analysis results show that both fracture interporosity flow and fracture storativity play an important role in the stability behavior of the system. It is shown that a diffusive boundary layer under the gravity field in fractured porous media with lower fracture storativity and/or higher fracture interporosity flow coefficient is more stable. We present scaling relations for the onset of convective instability in fractured aquifers with single and variable matrix block size distribution. These findings improve our understanding of density-driven flow in fractured aquifers and are important in the estimation of potential storage capacity, risk assessment, and storage site characterization and screening.

  13. Fracture mapping in geothermal fields with long-offset induction logging

    Energy Technology Data Exchange (ETDEWEB)

    Wilt, M.; Takasugi, Shinji; Uchida, Toshihiro [and others

    1997-12-31

    The mapping of producing fractures in a geothermal field is an important technical objective in field development. Locating, orienting, and assessing producing fractures can guide drilling programs and optimize the placement of production and injection wells. A long-offset multicomponent borehole induction resistivity tool capable of surviving the high temperatures encountered in geothermal wells has recently been developed in a NEDO project, {open_quotes}Deep-Seated Geothermal Reservoirs,{close_quotes} and tested in a high temperature environment. Several characteristics of this device make it ideal for detecting producing fractures. Whereas commercial induction logging devices have source-receiver separations of 1 m, this device has multiple sensors with separations up to 8 m, allowing for deeper penetration and the ability to straddle fracture-induced washout zones in boreholes. The three-component measurements also make it possible to map the strike and inclination of nearby fractures and other three-dimensional structures. This, in turn, allows for accurate projection of these structures into the space between wells. In this paper, we describe the design of the tool and show results of a performance test carried out in an oil-field steam flood. Data from vertical sensors are compared to conventional logging results and indicate the recent formation of a low-resistivity zone associated with high temperatures due to steam flood breakthrough. Horizontal field data indicate that the high-temperature zone is irregular in the vicinity of the borehole and more pronounced closest to the steam injector.

  14. kISMET: Stress and fracture characterization in a deep mine

    Science.gov (United States)

    Oldenburg, C. M.; Dobson, P. F.; Daley, T. M.; Birkholzer, J. T.; Cook, P. J.; Ajo Franklin, J. B.; Rutqvist, J.; Siler, D.; Kneafsey, T. J.; Nakagawa, S.; Wu, Y.; Guglielmi, Y.; Ulrich, C.; Marchesini, P.; Wang, H. F.; Haimson, B. C.; Sone, H.; Vigilante, P.; Roggenthen, W.; Doe, T.; Lee, M.; Mattson, E.; Huang, H.; Johnson, T. C.; Morris, J.; White, J. A.; Johnson, P. A.; Coblentz, D. D.; Heise, J.

    2016-12-01

    We are developing a community facility called kISMET (permeability (k) and Induced Seismicity Management for Energy Technologies) at the Sanford Underground Research Facility (SURF) in Lead, SD. The purpose of kISMET is to investigate stress and the effects of rock fabric on hydraulic fracturing. Although findings from kISMET may have broad applications that inform stress and fracturing in anisotropic rock, results will be most applicable to improving control of hydraulic fracturing for enhanced geothermal systems (EGS) in crystalline rock. At the kISMET site on the 4850 ft (1480 m depth) level of SURF, we have drilled and cored an array of nearly vertical boreholes in Precambrian phyllite. The array consists of four 50-m deep monitoring boreholes surrounding one 100-m deep borehole forming a 6 m-wide five-spot pattern at a depth of 1530 m. Previous investigations of the stress field at SURF suggest that the principal stress s1 is nearly vertical. By aligning the kISMET boreholes approximately with σ1, fractures created in the center borehole should in theory be perpendicular to σ3, the least principal horizontal stress. But the phyllite at kISMET has a strong fabric (foliation) that could influence fracturing. Stress measurements and stimulation using hydraulic fracturing will be carried out in the center borehole using a straddle packer and high-pressure pump. We will use an impression packer and image logs after stress testing and stimulation to determine fracture orientation and extent at the center borehole. In order to study the control of stress, rock fabric, and stimulation approach on size, aperture, and orientation of hydraulic fractures, we will carefully monitor the stress measurements and stimulation. For example, we will use continuous active source seismic (CASSM) in two of the monitoring boreholes to measure changes in seismic-wave velocity as water fills the fracture. Second, near real-time electrical resistance tomography (ERT) will be used in

  15. J-integral evaluation and stability analysis in the unstable ductile fracture

    International Nuclear Information System (INIS)

    Miyoshi, Toshiro; Yoshida, Yuichiro; Shiratori, Masaki.

    1984-01-01

    Concerning unstable ductile fracture, which is an important problem on the structural stability of line pipes, nuclear reactor piping and so on, the research on fracture mechanics parameters which control the beginning of the stable growth and unstable growth of cracks attracts interest. At present, as the parameters, the T-modulus based on J-integral crack tip opening angle, crack opening angle averaged over crack developing part, plastic work coefficient and so on have been proposed. The research on the effectiveness and inter-relation of these parameters is divided into generation phase and application phase, and by these researches, it was reported that all T-modulus, CTOA and COA took almost constant values in relation to crack development, except initial transition period. In order to decide which parameter is most appropriate, the detailed analysis is required. In this study, the analysis of unstable ductile fracture of a central crack test piece and a small tensile test piece was carried out by finite element method, and the evaluation of J-integral in relation to crack development, J-integral resistance value when COA is assumed to be a constant, the form of an unstable fracture occurring point and the compliance dependence were examined. The method of analysis, the evaluation of J-integral, J-integral resistance value, unstable fracture occurring point and stability diagram are described. (Kako, I.)

  16. Database for hydraulically conductive fractures. Update 2009

    International Nuclear Information System (INIS)

    Palmen, J.; Tammisto, E.; Ahokas, H.

    2010-03-01

    Posiva flow logging (PFL) with a 0.5 m test interval and made in 10 cm steps can be used for the determination of the depth of hydraulically conductive fractures. Together with drillhole wall images and fracture data from core logging, PFL provides possibilities to detect individual conductive fractures. In this report, the results of PFL are combined with fracture data on drillholes OL-KR41 - OL-KR48, OL-KR41B - OLKR45B and pilot holes ONK-PH8 - ONK-PH10. In addition, HTU-data measured by 2 m section length and 2 m steps in holes OL-KR39 and OL-KR40 at depths 300-700 m were analyzed and combined with fracture data in a similar way. The conductive fractures were first recognised from PFL data and digital drillhole images and then the fractures from the core logging that correspond to the ones picked from the digital drillhole images were identified. The conductive fractures were primarily recognised in the images based on the openness of fractures or a visible flow in the image. In most of the cases, no tails of flow were seen in the image. In these cases the conductive fractures were recognised in the image based on the openness of fractures and a matching depth. On the basis of the results hydraulically conductive fractures/zones could in most cases be distinguished in the drillhole wall images. An important phase in the work is the calibration of the depth of the image, flow logging and the HTU logging with the sample length. In addition to results of PFL-correlation, Hydraulic Testing Unit (HTU) data measured by 2 m section length and 2 m steps was studied at selected depths for holes OL-KR39, OL-KR40, OL-KR42 and OL-KR45. Due to low HTU section depth accuracy the conducting fractures were successfully correlated with Fracture Data Base (FDB) fractures only in drillholes OL-KR39 and OL-KR40. HTU-data depth matching in these two drillholes was performed using geophysical Single Point Resistance (SPR) data both from geophysical and PFL measurements as a depth

  17. Epidemiology of forearm fractures in adults in Denmark

    DEFF Research Database (Denmark)

    Abrahamsen, Bo; Jørgensen, N R; Schwarz, P

    2015-01-01

    with less detailed information. Rates were higher than previously estimated. INTRODUCTION: Despite a significant contribution to the overall burden of osteoporotic, nonvertebral fractures, relatively little information is available about age- and gender-specific incidence rates for many countries including...... Denmark. METHODS: We used national individual patient data on inpatient and outpatient treatment to calculate rates of forearm fractures, taking readmissions into account, with subtables for distal and proximal fractures. We also calculated ratios of forearm to hip fractures that may be useful when...

  18. Estimation scheme for unstable ductile fracture of pressure vessel

    International Nuclear Information System (INIS)

    Takahashi, Jun; Okamura, Hiroyuki; Sakai, Shinsuke

    1990-01-01

    This paper presents a new scheme for the estimation of unstable ductile fracture using the J-integral. The proposed method uses a load-versus-displacement diagram which is generated using fully plastic solutions. By this method, the phenomena of the ductile fracture can be grasped visually. Thus, the parametrical survey can be executed far more easily than before. Then, using the proposed method, unstable ductile fracture is analyzed for single-edge cracked plates under both uniform tension and pure bending. In addition, several parametrical surveys are performed concerning (1) J-controlled crack growth, (2) compliance of the structure, (3) ductility of the material (i.e., J-resistance curve), and (4) scale of the structure (i.e., screening criterion). As a result, it is shown that the proposed method is especially effective for the paramtrical study of unstable ductile fracture. (author)

  19. Hydraulic Fracture Growth in a Layered Formation based on Fracturing Experiments and Discrete Element Modeling

    Science.gov (United States)

    Yushi, Zou; Xinfang, Ma; Tong, Zhou; Ning, Li; Ming, Chen; Sihai, Li; Yinuo, Zhang; Han, Li

    2017-09-01

    Hydraulic fracture (HF) height containment tends to occur in layered formations, and it significantly influences the entire HF geometry or the stimulated reservoir volume. This study aims to explore the influence of preexisting bedding planes (BPs) on the HF height growth in layered formations. Laboratory fracturing experiments were performed to confirm the occurrence of HF height containment in natural shale that contains multiple weak and high-permeability BPs under triaxial stresses. Numerical simulations were then conducted to further illustrate the manner in which vertical stress, BP permeability, BP density(or spacing), pump rate, and fluid viscosity control HF height growth using a 3D discrete element method-based fracturing model. In this model, the rock matrix was considered transversely isotropic and multiple BPs can be explicitly represented. Experimental and numerical results show that the vertically growing HF tends to be limited by multi-high-permeability BPs, even under higher vertical stress. When the vertically growing HF intersects with the multi-high-permeability BPs, the injection pressure will be sharply reduced. If a low pumping rate or a low-viscosity fluid is used, the excess fracturing fluid leak-off into the BPs obviously decreases the rate of pressure build up, which will then limit the growth of HF. Otherwise, a higher pumping rate and/or a higher viscosity will reduce the leak-off time and fluid volume, but increase the injection pressure to drive the HF to grow and to penetrate through the BPs.

  20. Open Fractures of the Hand: Review of Pathogenesis and Introduction of a New Classification System.

    Science.gov (United States)

    Tulipan, Jacob E; Ilyas, Asif M

    2018-02-01

    Open fractures of the hand are a common and varied group of injuries. Although at increased risk for infection, open fractures of the hand are more resistant to infection than other open fractures. Numerous unique factors in the hand may play a role in the altered risk of postinjury infection. Current systems for the classification of open fractures fail to address the unique qualities of the hand. This article proposes a novel classification system for open fractures of the hand, taking into account the factors unique to the hand that affect its risk for developing infection after an open fracture. Copyright © 2017. Published by Elsevier Inc.

  1. Technology development on analysis program for measuring fracture toughness of irradiated specimens

    International Nuclear Information System (INIS)

    Shibata, Akira; Takada, Fumiki

    2007-03-01

    The fracture toughness which represents resistance for brittle or ductile fracture is one of the most important material property concerning linear and non-linear fracture mechanics analyses. In order to respond to needs of collecting data relating to fracture toughness of pressure vessel and austenitic stainless steels, fracture toughness test for irradiated materials has been performed in JMTR hot laboratory. On the other hand, there has been no computer program for analysis of fracture toughness using the test data obtained from the test apparatus installed in the hot cell. Therefore, only load-displacement data have been provided to users to calculate fracture toughness of irradiated materials. Recently, request of analysis of fracture toughness have been increased. Thus a computer program, which calculates the amount of the crack extension, the compliance and the fracture toughness from the data acquired from the test apparatus installed in the hot cell, has been developed. In the program unloading elastic compliance method is applied based on ASTM E1820-01. Through the above development, the request for the fracture toughness analysis can be satisfied and the fracture toughness of irradiated test specimens can be provided to users. (author)

  2. Role of MRI in hip fractures, including stress fractures, occult fractures, avulsion fractures

    International Nuclear Information System (INIS)

    Nachtrab, O.; Cassar-Pullicino, V.N.; Lalam, R.; Tins, B.; Tyrrell, P.N.M.; Singh, J.

    2012-01-01

    MR imaging plays a vital role in the diagnosis and management of hip fractures in all age groups, in a large spectrum of patient groups spanning the elderly and sporting population. It allows a confident exclusion of fracture, differentiation of bony from soft tissue injury and an early confident detection of fractures. There is a spectrum of MR findings which in part is dictated by the type and cause of the fracture which the radiologist needs to be familiar with. Judicious but prompt utilisation of MR in patients with suspected hip fractures has a positive therapeutic impact with healthcare cost benefits as well as social care benefits.

  3. The Role of Ultrasound Imaging of Callus Formation in the Treatment of Long Bone Fractures in Children

    International Nuclear Information System (INIS)

    Wawrzyk, Magdalena; Sokal, Jan; Andrzejewska, Ewa; Przewratil, Przemysław

    2015-01-01

    In the process of diagnosis and treatment of fractures, an X-ray study is typically performed. In modern medicine very important is the development of new diagnostic methods without adverse effects on the body. One of such techniques is ultrasound imaging. It has a high value in imaging most areas of the body, including the musculoskeletal system. Reports on the use of ultrasound in the evaluation of the callus are rare and this could be a method equivalent to or even better than standard radiographs. The aim of the study was to analyze the correlation of ultrasound with radiographs in imaging of callus formation after fractures of long bones in children and to analyze the correlation of vascular resistance index (RI) and the degree of vascularization of the callus with a subjective radiological assessment of the bone union quality. The prospective study was planned to qualify 50 children treated for long bones fractures of the arm, forearm, thigh and lower leg. Ultrasound diagnosis was carried out using a Philips iU22 camera equipped with a linear probe with 17-5-MHz resolution and MSK Superficial program. During ultrasound examination measurements of the callus were performed. Using the Power Doppler callus vascularity was visualized and vascular resistance index (RI) was measured. The same measurements were made within the corresponding area of the healthy limb. The results obtained by ultrasound were compared with radiograph measurements and with the subjective assessment of the callus quality. Preliminary results were developed on a group of 24 patients, where 28 fractured bones and 28 corresponding healthy bones were examined. Fifteen boys and 9 girls participated in the study. The average age at injury was, respectively, 11 and 9 years. In both groups fractures without displacement were the most frequent. A similar frequency was observed in fractures requiring reposition and subperiosteal fractures. In contrast, fractures with a slight displacement of the

  4. The Role of Ultrasound Imaging of Callus Formation in the Treatment of Long Bone Fractures in Children.

    Science.gov (United States)

    Wawrzyk, Magdalena; Sokal, Jan; Andrzejewska, Ewa; Przewratil, Przemysław

    2015-01-01

    In the process of diagnosis and treatment of fractures, an X-ray study is typically performed. In modern medicine very important is the development of new diagnostic methods without adverse effects on the body. One of such techniques is ultrasound imaging. It has a high value in imaging most areas of the body, including the musculoskeletal system. Reports on the use of ultrasound in the evaluation of the callus are rare and this could be a method equivalent to or even better than standard radiographs. The aim of the study was to analyze the correlation of ultrasound with radiographs in imaging of callus formation after fractures of long bones in children and to analyze the correlation of vascular resistance index (RI) and the degree of vascularization of the callus with a subjective radiological assessment of the bone union quality. The prospective study was planned to qualify 50 children treated for long bones fractures of the arm, forearm, thigh and lower leg. Ultrasound diagnosis was carried out using a Philips iU22 camera equipped with a linear probe with 17-5-MHz resolution and MSK Superficial program. During ultrasound examination measurements of the callus were performed. Using the Power Doppler callus vascularity was visualized and vascular resistance index (RI) was measured. The same measurements were made within the corresponding area of the healthy limb. The results obtained by ultrasound were compared with radiograph measurements and with the subjective assessment of the callus quality. Preliminary results were developed on a group of 24 patients, where 28 fractured bones and 28 corresponding healthy bones were examined. Fifteen boys and 9 girls participated in the study. The average age at injury was, respectively, 11 and 9 years. In both groups fractures without displacement were the most frequent. A similar frequency was observed in fractures requiring reposition and subperiosteal fractures. In contrast, fractures with a slight displacement of the

  5. Paratrooper's ankle fracture: posterior malleolar fracture.

    Science.gov (United States)

    Young, Ki Won; Kim, Jin-su; Cho, Jae Ho; Kim, Hyung Seuk; Cho, Hun Ki; Lee, Kyung Tai

    2015-03-01

    We assessed the frequency and types of ankle fractures that frequently occur during parachute landings of special operation unit personnel and analyzed the causes. Fifty-six members of the special force brigade of the military who had sustained ankle fractures during parachute landings between January 2005 and April 2010 were retrospectively analyzed. The injury sites and fracture sites were identified and the fracture types were categorized by the Lauge-Hansen and Weber classifications. Follow-up surveys were performed with respect to the American Orthopedic Foot and Ankle Society ankle-hindfoot score, patient satisfaction, and return to preinjury activity. The patients were all males with a mean age of 23.6 years. There were 28 right and 28 left ankle fractures. Twenty-two patients had simple fractures and 34 patients had comminuted fractures. The average number of injury and fractures sites per person was 2.07 (116 injuries including a syndesmosis injury and a deltoid injury) and 1.75 (98 fracture sites), respectively. Twenty-three cases (41.07%) were accompanied by posterior malleolar fractures. Fifty-five patients underwent surgery; of these, 30 had plate internal fixations. Weber type A, B, and C fractures were found in 4, 38, and 14 cases, respectively. Based on the Lauge-Hansen classification, supination-external rotation injuries were found in 20 cases, supination-adduction injuries in 22 cases, pronation-external rotation injuries in 11 cases, tibiofibular fractures in 2 cases, and simple medial malleolar fractures in 2 cases. The mean follow-up period was 23.8 months, and the average follow-up American Orthopedic Foot and Ankle Society ankle-hindfoot score was 85.42. Forty-five patients (80.36%) reported excellent or good satisfaction with the outcome. Posterior malleolar fractures occurred in 41.07% of ankle fractures sustained in parachute landings. Because most of the ankle fractures in parachute injuries were compound fractures, most cases had to

  6. Inclusion-initiated fracture model for ceramics

    International Nuclear Information System (INIS)

    Sung, J.; Nicholson, P.S.

    1990-01-01

    The fracture of ceramics initiating from a typical inclusion is analyzed. The inclusion is considered to have a thermal expansion coefficient and fracture toughness lower than those of the matrix and a Young's modulus higher than that of the matrix. Inclusion-initiated fracture is modeled for a spherical inclusion using a weight function method to compute the residual stress intensity factor for a part-through elliptical crack. The results are applied to an α-Al 2 O 3 inclusion embedded in a tetragonal ZrO 2 ceramic. The strength predictions agree well with experimental data

  7. Scapular fracture: lower severity and mortality

    Directory of Open Access Journals (Sweden)

    Javad Salimi

    Full Text Available CONTEXT AND OBJECTIVE: The presence of scapular fracture is believed to be associated with high rates of other injuries and accompanying morbidities. The aim was to study injury patterns and their overall outcomes in patients with scapula fractures. DESIGN AND SETTING: Cross-sectional study of trauma patients treated at six general hospitals in Tehran. METHODS: One-year trauma records were obtained from six general hospitals Among these, forty-one had sustained a scapular fracture and were included in this study. RESULTS: Scapular fracture occurred predominantly among 20 to 50-year-old patients (78%. Road traffic accidents (RTAs were the main cause of injury (73.2%; 30/41. Pedestrians accounted for 46.7% (14/30 of the injuries due to RTAs. Falls were the next most common cause, accounting for seven cases (17.1%. Body fractures were the most common type of scapular fractures (80%. Eighteen patients (43.9% had isolated scapular fractures. Limb fracture was the most common associated injury, detected in 18 cases (43.9%. Three patients (7.3% had severe injuries (injury severity score, ISS > 16 which resulted in one death (2.4%. The majority of the patients were treated conservatively (87.8%. CONCLUSIONS: Patients with scapula fractures have more severe underlying chest injuries and clavicle fractures. However, this did not correlate with higher rates of injury severity score, intensive care unit admission or mortality.

  8. Specification of matrix cleanup goals in fractured porous media.

    Science.gov (United States)

    Rodríguez, David J; Kueper, Bernard H

    2013-01-01

    Semianalytical transient solutions have been developed to evaluate what level of fractured porous media (e.g., bedrock or clay) matrix cleanup must be achieved in order to achieve compliance of fracture pore water concentrations within a specified time at specified locations of interest. The developed mathematical solutions account for forward and backward diffusion in a fractured porous medium where the initial condition comprises a spatially uniform, nonzero matrix concentration throughout the domain. Illustrative simulations incorporating the properties of mudstone fractured bedrock demonstrate that the time required to reach a desired fracture pore water concentration is a function of the distance between the point of compliance and the upgradient face of the domain where clean groundwater is inflowing. Shorter distances correspond to reduced times required to reach compliance, implying that shorter treatment zones will respond more favorably to remediation than longer treatment zones in which back-diffusion dominates the fracture pore water response. For a specified matrix cleanup goal, compliance of fracture pore water concentrations will be reached sooner for decreased fracture spacing, increased fracture aperture, higher matrix fraction organic carbon, lower matrix porosity, shorter aqueous phase decay half-life, and a higher hydraulic gradient. The parameters dominating the response of the system can be measured using standard field and laboratory techniques. © 2012, The Author(s). Ground Water © 2012, National Ground Water Association.

  9. Self-perception of fracture risk: what can it tell us?

    Science.gov (United States)

    Litwic, A E; Compston, J E; Wyman, A; Siris, E S; Gehlbach, S H; Adachi, J D; Chapurlat, R; Díez-Pérez, A; LaCroix, A Z; Nieves, J W; Netelenbos, J C; Pfeilschifter, J; Rossini, M; Roux, C; Saag, K G; Silverman, S; Watts, N B; Greenspan, S L; March, L; Gregson, C L; Cooper, C; Dennison, E M

    2017-12-01

    In this study, we report that self-perception of fracture risk captures some aspect of fracture risk not currently measured using conventional fracture prediction tools and is associated with improved medication uptake. It suggests that adequate appreciation of fracture risk may be beneficial and lead to greater healthcare engagement and treatment. This study aimed to assess how well self-perception of fracture risk, and fracture risk as estimated by the fracture prediction tool FRAX, related to fracture incidence and uptake and persistence of anti-osteoporosis medication among women participating in the Global Longitudinal study of Osteoporosis in Women (GLOW). GLOW is an international cohort study involving 723 physician practices across 10 countries in Europe, North America and Australia. Aged ≥ 55 years, 60,393 women completed baseline questionnaires detailing medical history, including co-morbidities, fractures and self-perceived fracture risk (SPR). Annual follow-up included self-reported incident fractures and anti-osteoporosis medication (AOM) use. We calculated FRAX risk without bone mineral density measurement. Of the 39,241 women with at least 1 year of follow-up data, 2132 (5.4%) sustained an incident major osteoporotic fracture over 5 years of follow-up. Within each SPR category, risk of fracture increased as the FRAX categorisation of risk increased. In GLOW, only 11% of women with a lower baseline SPR were taking AOM at baseline, compared with 46% of women with a higher SPR. AOM use tended to increase in the years after a reported fracture. However, women with a lower SPR who were fractured still reported lower AOM rates than women with or without a fracture but had a higher SPR. These results suggest that SPR captures some aspect of fracture risk not currently measured using conventional fracture prediction tools and is also associated with improved medication uptake.

  10. Review of resistance factor for steel: resistance distributions and resistance factor calibration

    International Nuclear Information System (INIS)

    Schmidt, B.J.; Bartlett, F.M.

    2002-01-01

    Changes in the Canadian steel industry warrant a review of the steel resistance factor in CSA Standard S16 (formerly S16.1) 'Limit states design of steel structures', originally calibrated in the landmark study by Kennedy and Gad Aly in 1980. This paper presents statistical parameters for the bending, compression, and tension resistances of W, WWF, and HSS components produced since 1999 that have been derived from geometric and material properties presented in a companion paper. The resistance factor for steel was recalibrated for the live and dead load combination in the 1995 National Building Code of Canada. A resistance factor of 0.95 is suitable for laterally supported beams, stocky columns, and tension members failing by yield of the gross section, whereas the current value of 0.90 is appropriate for intermediate columns and tension members failing by fracture of the net section. (author)

  11. Fracture toughness of manet II steel

    International Nuclear Information System (INIS)

    Gboneim, M.M.; Munz, D.

    1997-01-01

    High fracture toughness was evaluated according to the astm and chromium (9-12) martensitic steels combine high strength and toughness with good corrosion and oxidation resistance in a range of environments, and also show relatively high creep strength at intermediate temperatures. They therefore find applications in, for example, the offshore oil and gas production and chemical industries i pipe work and reaction vessels, and in high temperature steam plant in power generation systems. Recently, the use of these materials in the nuclear field was considered. They are candidates as tubing materials for breeder reactor steam generators and as structural materials for the first wall and blanket in fusion reactors. The effect of ageing on the tensile properties and fracture toughness of a 12 Cr-1 Mo-Nb-v steel, MANET II, was investigated in the present work. Tensile specimens and compact tension (CT) specimens were aged at 550 degree C for 1000 h. The japanese standards. Both microstructure and fracture surface were examined using optical and scanning electron microscopy (SEM). The results showed that ageing did not affect the tensile properties. However, the fracture toughness K Ic and the tearing modules T were reduced due to the ageing treatment. The results were discussed in the light of the chemical composition and the fracture surface morphology. 9 figs., 3 tabs

  12. The International Costs and Utilities Related to Osteoporotic Fractures Study (ICUROS)--quality of life during the first 4 months after fracture.

    Science.gov (United States)

    Borgström, F; Lekander, I; Ivergård, M; Ström, O; Svedbom, A; Alekna, V; Bianchi, M L; Clark, P; Curiel, M D; Dimai, H P; Jürisson, M; Kallikorm, R; Lesnyak, O; McCloskey, E; Nassonov, E; Sanders, K M; Silverman, S; Tamulaitiene, M; Thomas, T; Tosteson, A N A; Jönsson, B; Kanis, J A

    2013-03-01

    The quality of life during the first 4 months after fracture was estimated in 2,808 fractured patients from 11 countries. Analysis showed that there were significant differences in the quality of life (QoL) loss between countries. Other factors such as QoL prior fracture and hospitalisation also had a significant impact on the QoL loss. The International Costs and Utilities Related to Osteoporotic Fractures Study (ICUROS) was initiated in 2007 with the objective of estimating costs and quality of life related to fractures in several countries worldwide. The ICUROS is ongoing and enrols patients in 11 countries (Australia, Austria, Estonia, France, Italy, Lithuania, Mexico, Russia, Spain, UK and the USA). The objective of this paper is to outline the study design of ICUROS and present results regarding the QoL (measured using the EQ-5D) during the first 4 months after fracture based on the patients that have been thus far enrolled ICUROS. ICUROS uses a prospective study design where data (costs and quality of life) are collected in four phases over 18 months after fracture. All countries use the same core case report forms. Quality of life was collected using the EQ-5D instrument and a time trade-off questionnaire. The total sample for the analysis was 2,808 patients (1,273 hip, 987 distal forearm and 548 vertebral fracture). For all fracture types and countries, the QoL was reduced significantly after fracture compared to pre-fracture QoL. A regression analysis showed that there were significant differences in the QoL loss between countries. Also, a higher level of QoL prior to the fracture significantly increased the QoL loss and patients who were hospitalised for their fracture also had a significantly higher loss compared to those who were not. The findings in this study indicate that there appear to be important variations in the QoL decrements related to fracture between countries.

  13. Risk factors for hip fracture among institutionalised older people.

    Science.gov (United States)

    Chen, Jian Sheng; Sambrook, Philip N; Simpson, Judy M; Cameron, Ian D; Cumming, Robert G; Seibel, Markus J; Lord, Stephen R; March, Lyn M

    2009-07-01

    risk factors for hip fracture in community-dwelling individuals have been extensively studied, but there have been fewer studies of institutionalised older people. a total of 1,894 older people (1,433 females, 461 males; mean age 86 years, SD 7.1 years) were recruited from 52 nursing homes and 30 intermediate-care nursing care facilities in Australia during March 1999 and February 2003. We assessed clinical risk factors for hip fracture and skeletal fragility by calcaneus broadband ultrasound attenuation (BUA) at baseline and then followed up for fracture for 4 years. Hip fractures were validated by x-ray reports. Survival analysis with age as a time-dependent covariate was used to analyse the data. during a mean follow-up period of 2.65 years (SD 1.38), 201 hip fractures in 191 residents were recorded, giving an overall hip fracture incidence rate of 4.0% per person year (males 3.6% and females 4.1%). Residents living in intermediate-care hostels had a higher crude hip fracture rate (4.6% vs. 3.0%) than those living in high-care nursing homes. In multivariate analysis, an increased risk of hip fracture was significantly associated with older age, cognitive impairment, a history of fracture since age 50, lower body weight, longer lower leg length and poorer balance in intermediate-care hostel residents, but not with lower BUA. institutionalised older people, who are at a higher risk of hip fracture than community-dwelling individuals, have differences in some risk factors for hip fracture that should be considered in targeting intervention programs.

  14. Gender differences in the clinical characteristics of traumatic spinal fractures among the elderly.

    Science.gov (United States)

    Wang, Hongwei; Xiang, Liangbi; Liu, Jun; Zhou, Yue; Ou, Lan

    2014-01-01

    In order to illustrate the epidemiology of traumatic spinal fractures among the elderly, with an emphasis on exploring gender differences in clinical characteristics, we retrospectively reviewed hospital records on all elderly patients with traumatic spinal fractures who were 60 years of age or older at two university-affiliated hospitals between January 2001 and December 2010. A total of 642 elderly patients with traumatic spinal fractures were identified, of whom 249 were male and 393 were female. Accidental falls from low heights were the most common cause of traumatic spinal fractures among the elderly (50.8%). Frequencies of falls from high heights and direct collisions with a blunt object were significantly higher in male than in female elderly patients (Pspinal fractures, spinal cord injuries, associated non-spinal injuries (ASOIs) and mean injury severity scores (ISSs) were significantly higher in males than in females (Pspinal fractures in females were significantly higher than in males (Pspinal fractures among the elderly. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Computed tomography of pelvic fractures

    Energy Technology Data Exchange (ETDEWEB)

    Kimoto, Makoto; Hashimoto, Keiji; Hiraki, Yoshio

    1984-12-01

    Plain x-ray and computed tomographic (CT) findings were compared in 7 patients with pelvic fractures (2 males and 5 females) aged between 35 and 50 year. Plain x-rays had a higher sensitivity than CT in detecting fractures of the ischiatic and pubic ramuses, and deviation of bone fragments. CT was superior to plain x-rays near the acetabulum and in detecting deviation of bone fragments. Although there were no differences between the two modalities in detecting fractures of the wing of ilium, CT was more useful than plain x-rays in visualizing deviation of bone fragments. CT clearly visualized not only fractures but also injuries of the soft tissues, such as pelvic viscera and muscles, and the presence of hematoma. CT seems to be a useful method for observing the condition and process of pelvic injuries and for deciding treatment protocols.

  16. Fracture occurrence from radionuclides in the skeleton

    Energy Technology Data Exchange (ETDEWEB)

    Lloyd, R.D.; Taylor, G.N.; Miller, S.C.

    2000-06-01

    Because skeletal fractures were an important finding among persons contaminated with {sup 226}Ra, experience with fractures among dogs in the colony was summarized to determine the projected significance for persons contaminated with bone-seeking radionuclides. Comparison by Fisher's Exact Test of lifetime fracture occurrence in the skeletons of beagles injected as young adults suggested that for animals given {sup 226}Ra, {sup 228}Ra, {sup 228}Th, or {sup 239}Pu citrate, there was probably an excess over controls in fractures of the ribs, leg bones, spinous processes, and pelvis (os coxae) plus the mandible for dogs given {sup 226}Ra and the scapulae for dogs given {sup 228}Ra or 228 Th. Regression analysis indicated that significantly elevated fracture occurrence was especially notable at the higher radiation doses, at about 50 Gy average skeletal dose for {sup 239}Pu, 140 Gy for {sup 226}Ra, about 40 Gy for {sup 228}Ra, and more than 15 Gy for {sup 228}Th. The average number of fractures per dog was significantly elevated over that noted in controls for the highest radiation doses of {sup 239}Pu and {sup 226}Ra and for the higher doses of {sup 228}Ra and {sup 228}Th. For those dogs given {sup 90}Sr citrate, there was virtually no important difference from control beagles not given radionuclides, even at group mean cumulative skeletal radiation doses up to 101 Gy. Because of a large proportion of dogs with fractures that died with bone malignancy (even at dosage levels lower than those exhibiting an excess average number of fractures per dog), they conclude that fracture would not be an important endpoint at lower levels of plutonium contamination in humans such as would be expected to occur from occupational or environmental exposure.

  17. Estudo comparativo da resistência à fratura de pré-molares superiores íntegros e restaurados com amálgama aderido Comparative study of the fracture resistance of sound upper premolars and upper premolars restored with bonded amalgam

    Directory of Open Access Journals (Sweden)

    André Marcelo Peruchi Minto

    2002-06-01

    Full Text Available No presente estudo avaliou-se, in vitro, a resistência à fratura de pré-molares superiores preparados com cavidades de classe II compostas (conservadoras e extensas restauradas com amálgama aderido a dois tipos diferentes de sistemas adesivos. Setenta dentes foram divididos em 4 grupos: grupo 1 ou controle com 10 dentes íntegros; grupo 2 com 20 dentes, sendo 10 cavidades conservadoras e 10 extensas restauradas com amálgama sem qualquer tipo de forramento. O grupo 3 e o grupo 4 foram compostos da mesma forma que o grupo 2, sendo que o primeiro recebeu cimento de ionômero de vidro (Vitrebond - 3M e o segundo, adesivo dental (Scotchbond Multi-Purpose Plus - 3M, antes de serem restaurados. Os dentes haviam sido incluídos anteriormente em cilindros de PVC e fixados com resina acrílica. Após serem restaurados e termociclados, foram submetidos à fratura por força de compressão em uma máquina universal de testes EMIC-MEM 2000. Após análise de variância e aplicação do teste complementar de Tukey, concluiu-se que os sistemas adesivos utilizados condicionaram o aumento da resistência à fratura da estrutura dental nas cavidades convencionais, sendo os dentes com cavidades conservadoras mais resistentes em qualquer condição experimental.The purpose of this in vitro study was to determine the fracture resistance of upper premolars which had received class II preparations (conservative and extensive and were restored with bonded amalgam, with two different adhesive systems. Seventy teeth were divided in four groups: group 1 (control, with ten sound teeth; group 2, with twenty prepared teeth (10 teeth received conservative cavities and 10, extensive cavities restored with amalgam without any kind of liner; groups 3 and 4, similar to group 2, though with linings of glass ionomer cement (Vitrebond - 3M (group 3 and dental adhesive (Scotchbond Multi-Purpose Plus - 3M (group 4. The teeth were previously fixed in PVC cylinders with acrylic

  18. Fracture Mechanics

    International Nuclear Information System (INIS)

    Jang, Dong Il; Jeong, Gyeong Seop; Han, Min Gu

    1992-08-01

    This book introduces basic theory and analytical solution of fracture mechanics, linear fracture mechanics, non-linear fracture mechanics, dynamic fracture mechanics, environmental fracture and fatigue fracture, application on design fracture mechanics, application on analysis of structural safety, engineering approach method on fracture mechanics, stochastic fracture mechanics, numerical analysis code and fracture toughness test and fracture toughness data. It gives descriptions of fracture mechanics to theory and analysis from application of engineering.

  19. Dynamic fracture initiation in brittle materials under combined mode I/II loading

    International Nuclear Information System (INIS)

    Nakano, M.; Kishida, K.; Yamauchi, Y.; Sogabe, Y.

    1994-01-01

    A new test method has been developed to measure the resistance of dynamic fracture initiation in brittle materials under combined mode I/II loadings. The Brazilian disks with center-cracks have been fractured under oblique impact loadings in diametral-compression. The dynamic stress intensity factors of mode I and II are evaluated from the superposition integrals of the step response functions for the cracked disk. The experimental results are presented to elucidate the influence of loading rate on the combined mode fracture toughness for ceramics and glasses. (orig.)

  20. High revision rate but good healing capacity of atypical femoral fractures. A comparison with common shaft fractures.

    Science.gov (United States)

    Schilcher, Jörg

    2015-12-01

    Healing of complete, atypical femoral fractures is thought to be impaired, but the evidence is weak and appears to be based on the delayed healing observed in patients with incomplete atypical fractures. Time until fracture healing is difficult to assess, therefore we compared the reoperation rates between women with complete atypical femoral fractures and common femoral shaft fractures. We searched the orthopaedic surgical registry in Östergötland County for patients with subtrochanteric and femoral shaft fractures (ICD-10 diagnosis codes S72.2, S72.3 and M84.3F) between January 1st 2007 and December 31st 2013. Out of 895 patients with surgically treated femoral shaft fractures, 511 were women 50 years of age or older. Among these we identified 24 women with atypical femoral shaft fractures, and 71 with common shaft fractures. Reoperations were performed in 6 and 5 patients, respectively, odds ratio 4.4 (95% CI 1.2 to 16.1). However, 5 reoperations in the atypical fracture group could not be ascribed to poor healing. In 3 patients the reoperation was due to a new fracture proximal to a standard intramedullary nail. In 2 patients the distal locking screws were removed due to callus formation that was deemed incomplete 5 months post-operatively. The one patient with poor healing showed faint callus formation at 5 months when the fracture was dynamised and callus remained sparse at 11 months. Among patients with common shaft fractures, 2 reoperations were performed to remove loose screws, 2 because of peri-implant fractures and 1 reoperation due to infection. Reoperation rates in patients with complete atypical femoral fractures are higher than in patients with common shaft fractures. The main reason for failure was peri-implant fragility fractures which might be prevented with the use of cephalomedullary nails at the index surgery. Fracture healing however, seems generally good. A watchful waiting approach is advocated in patients with fractures that appear to

  1. Effect of temperature on the elastic-plastic fracture toughness behavior of Inconel X-750

    International Nuclear Information System (INIS)

    Mills, W.J.

    1977-09-01

    The elastic-plastic J/sub Ic/ fracture toughness response of precipitation heat treated Inconel X-750 has been evaluated by the multi-specimen resistance curve (R-curve) technique at room temperature, 800 0 F (427 0 C), and 1000 0 F (538 0 C). The value of J/sub Ic/ for this nickel-base superalloy was found to be relatively independent of temperature over the test temperature range. On the other hand, the slopes of the fracture toughness R-curves were steeper at 800 and 1000 0 F (427 and 538 0 C) than at 75 0 F (24 0 C), thereby indicating that the resistance to crack extension was considerably greater at elevated temperatures, Metallographic and electron fractographic examination of the Inconel X-750 fracture surfaces revealed that this slope change phenomenon was associated with an intergranular to transgranular fracture mechanism transition. Under room temperature conditions, crack extension occurred primarily by an intergranular dimple rupture mechanism attributed to microvoid coalescence along a grain boundary denuded region. In the 800 to 1000 0 F (427 to 538 0 C) regime, the fracture surface was dominated by a faceted transgranular morphology

  2. Impact of Oxidative Dissolution on Black Shale Fracturing: Implication for Shale Fracturing Treatment Design

    Science.gov (United States)

    You, L.; Chen, Q.; Kang, Y.; Cheng, Q.; Sheng, J.

    2017-12-01

    Black shales contain a large amount of environment-sensitive compositions, e.g., clay minerals, carbonate, siderite, pyrite, and organic matter. There have been numerous studies on the black shales compositional and pore structure changes caused by oxic environments. However, most of the studies did not focus on their ability to facilitate shale fracturing. To test the redox-sensitive aspects of shale fracturing and its potentially favorable effects on hydraulic fracturing in shale gas reservoirs, the induced microfractures of Longmaxi black shales exposed to deionized water, hydrochloric acid, and hydrogen peroxide at room-temperature for 240 hours were imaged by scanning electron microscopy (SEM) and CT-scanning in this paper. Mineral composition, acoustic emission, swelling, and zeta potential of the untreated and oxidative treatment shale samples were also recorded to decipher the coupled physical and chemical effects of oxidizing environments on shale fracturing processes. Results show that pervasive microfractures (Fig.1) with apertures ranging from tens of nanometers to tens of microns formed in response to oxidative dissolution by hydrogen peroxide, whereas no new microfracture was observed after the exposure to deionized water and hydrochloric acid. The trajectory of these oxidation-induced microfractures was controlled by the distribution of phyllosilicate framework and flaky or stringy organic matter in shale. The experiments reported in this paper indicate that black shales present the least resistance to crack initiation and subcritical slow propagation in hydrogen peroxide, a process we refer to as oxidation-sensitive fracturing, which are closely related to the expansive stress of clay minerals, dissolution of redox-sensitive compositions, destruction of phyllosilicate framework, and the much lower zeta potential of hydrogen peroxide solution-shale system. It could mean that the injection of fracturing water with strong oxidizing aqueous solution may

  3. On the importance of aging to the crack growth resistance of human enamel.

    Science.gov (United States)

    Yahyazadehfar, Mobin; Zhang, Dongsheng; Arola, Dwayne

    2016-03-01

    With improvements in oral health and an overall increase in quality of life, the percentage of fully or largely dentate seniors is increasing. Understanding the effects of aging on the mechanical properties of teeth is essential to the maintenance of lifelong oral health. In this investigation the effects of aging on the fracture toughness of human enamel were evaluated from incremental crack growth experiments performed on tissue of donor teeth representing "young" (17 ⩽ age ⩽ 25) and "old" (age ⩾ 55) age groups. Results showed that the old enamel exhibited significantly lower resistance to fracture than that of the young tissue in two orthogonal directions of crack growth. For crack growth transverse to the enamel rods, the fracture toughness of the old enamel (0.37 ± 0.15 MPa m(0.5)) was nearly 70% lower than that of tissue from the young teeth (1.23 ± 0.20 MPa m(0.5)). Based on results from a mechanistic analysis of crack growth, the reduction in fracture resistance is attributed to a decrease in the degree of extrinsic toughening. The practice of restorative dentistry should account for these changes in tooth tissues in the treatment of senior patients. The mechanical behavior of enamel has been studied for over 3 decades. Due to the limited volume of tissue available for evaluation, past work has been largely based on indentation methods. In this investigation we have evaluated the resistance to fracture of human enamel using a conventional fracture mechanics approach and incremental crack growth. We compared the fracture resistance of cuspal enamel obtained from the teeth of representative "young" and "old" donor groups. Our results show that there is a substantial reduction in the resistance to fracture with age, that it is anisotropic, and that the degradation is more severe than that which occurs to dentin. As such, we feel this work is a significant contribution to the field. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All

  4. Subclinical Thyroid Dysfunction and the Risk for Fractures

    Science.gov (United States)

    Wirth, Christina D.; Blum, Manuel R.; da Costa, Bruno R.; Baumgartner, Christine; Collet, Tinh-Hai; Medici, Marco; Peeters, Robin P.; Aujesky, Drahomir; Bauer, Douglas C.; Rodondi, Nicolas

    2015-01-01

    Background Data on the association between subclinical thyroid dysfunction and fractures conflict. Purpose To assess the risk for hip and nonspine fractures associated with subclinical thyroid dysfunction among prospective cohorts. Data Sources Search of MEDLINE and EMBASE (1946 to 16 March 2014) and reference lists of retrieved articles without language restriction. Study Selection Two physicians screened and identified prospective cohorts that measured thyroid function and followed participants to assess fracture outcomes. Data Extraction One reviewer extracted data using a standardized protocol, and another verified data. Both reviewers independently assessed methodological quality of the studies. Data Synthesis The 7 population-based cohorts of heterogeneous quality included 50 245 participants with 1966 hip and 3281 nonspine fractures. In random-effects models that included the 5 higher-quality studies, the pooled adjusted hazard ratios (HRs) of participants with subclinical hyperthyroidism versus euthyrodism were 1.38 (95% CI, 0.92 to 2.07) for hip fractures and 1.20 (CI, 0.83 to 1.72) for nonspine fractures without statistical heterogeneity (P = 0.82 and 0.52, respectively; I2 = 0%). Pooled estimates for the 7 cohorts were 1.26 (CI, 0.96 to 1.65) for hip fractures and 1.16 (CI, 0.95 to 1.42) for nonspine fractures. When thyroxine recipients were excluded, the HRs for participants with subclinical hyperthyroidism were 2.16 (CI, 0.87 to 5.37) for hip fractures and 1.43 (CI, 0.73 to 2.78) for nonspine fractures. For participants with subclinical hypothyroidism, HRs from higher-quality studies were 1.12 (CI, 0.83 to 1.51) for hip fractures and 1.04 (CI, 0.76 to 1.42) for nonspine fractures (P for heterogeneity = 0.69 and 0.88, respectively; I2 = 0%). Limitations Selective reporting cannot be excluded. Adjustment for potential common confounders varied and was not adequately done across all studies. Conclusion Subclinical hyperthyroidism might be associated with

  5. Development of a plastic fracture methodology for nuclear systems

    International Nuclear Information System (INIS)

    Marston, T.U.; Jones, R.L.; Kanninen, M.F.; Mowbray, D.F.

    1981-01-01

    This paper describes research conducted to develop a fundamental basis for flaw tolerance assessment procedures suitable for components exhibiting ductile behavior. The research was composed of an integrated combination of stable crack growth experiments and elastic-plastic analyses. A number of candidate fracture criteria were assembled and investigated to determine the proper basis for plastic fracture mechanics assessments. The results demonstrate that many different fracture criteria can be used as the basis of a resistance curve approach to predicting stable crack growth and fracture instability. While all have some disadvantages, none is completely unacceptable. On balance, the best criteria were found to be the J-integral for initiation and limited amounts of stable crack growth and the local crack-tip opening angle for extended amounts of stable growth. A combination of the two, which may preserve the advantages of each while reducing their disadvantages, also was suggested by these results. The influence of biaxial and mixed flat/shear fracture behavior was investigated and found to not alter the basic results. Further work in the development of simplified ductile fracture analyses for routine engineering assessments of nuclear pressure vessels and piping evolving from this research is also described

  6. Epidemiology and risk factors of humerus fractures among skiers and snowboarders.

    Science.gov (United States)

    Bissell, Benjamin T; Johnson, Robert J; Shafritz, Adam B; Chase, Derek C; Ettlinger, Carl F

    2008-10-01

    The incidence of humerus fractures while participating in snowboarding and skiing is undefined. Very little is known about the risk factors associated with these fractures. Snowboarders are at increased risk for sustaining humerus fractures when compared with skiers. In addition, the types of fractures, laterality, and risk factors differ between the 2 groups. Case-control study; Level of evidence, 3. At a major ski area clinic, 318 humerus fractures were evaluated over 34 seasons. Radiographs were classified according to the AO and Neer systems. Patient data were analyzed and compared with that of a control population of uninjured skiers and snowboarders to determine incidence and risk factors. The incidence of humerus fractures among snowboarders (0.062 per 1000 snowboarder days) was significantly higher than that of skiers (0.041 per 1000, P Jumping was involved in 28.3% of humerus fractures among snowboarders and in 5.4% among skiers. Skiers with humerus fractures were more skilled, older, and fell less frequently than controls. Snowboarders were less skilled, younger, and fell at a similar rate compared with controls. Snowboarders are at significantly higher risk of sustaining humerus fractures than skiers. In skiers, humerus fractures show no laterality and most often involve the proximal humerus. In contrast, snowboarders more often fracture the left humerus at the diaphysis.

  7. Location of Sternal Fractures as a Possible Marker for Associated Injuries

    Directory of Open Access Journals (Sweden)

    Max J. Scheyerer

    2013-01-01

    Full Text Available Introduction. Sternal fractures often occur together with serious and life-threatening additional injuries. This retrospective study was designed to assess concomitant injuries and develop a correlation between fracture location and the severity of injury. Methods. All patients ( diagnosed with a fracture of the sternum by means of a CT scan were analysed with respect to accident circumstances, fracture morphology and topography, associated injuries, and outcome. Results. Isolated sternal fractures occurred in 9%. In all other admissions, concomitant injuries were diagnosed: mainly rip fractures (64%, injury to the head (48%, the thoracic spine (38%, lumbar spine (27%, and cervical spine (22%. Predominant fracture location was the manubrium sterni. In these locations, the observed mean ISS was the highest. They were strongly associated with thoracic spine and other chest injuries. Furthermore, the incidence of head injuries was significantly higher. ICU admission was significantly higher in patients with manubrium sterni fractures. Conclusion. Sternal fractures are frequently associated with other injuries. It appears that the fracture location can provide important information regarding concomitant injuries. In particular, in fractures of manubrium sterni, the need for further detailed clinical and radiologic workup is necessary to detect the frequently associated injuries and reduce the increased mortality.

  8. Characteristics and interpretation of fracture-filled gas hydrate: an example from the Ulleung Basin, East Sea of Korea

    Science.gov (United States)

    Lee, Myung Woong; Collett, Timothy S.

    2013-01-01

    Through the use of 2-D and 3-D seismic data, a total of thirteen sites were selected and drilled in the East Sea of Korea in 2010. A suite of logging-while-drilling (LWD) logs was acquired at each site. LWD logs from the UBGH2-3A well indicate significant gas hydrate in clay-bearing sediments including several zones with massive gas hydrate with a bulk density less than 1.0 g/m3 for depths between 5 and 103 m below the sea floor. The UBGH2-3A well was drilled on a seismically identified chimney structure with a mound feature at the sea floor. Average gas hydrate saturations estimated from the isotropic analysis of ring resistivity and P-wave velocity logs are 80 ± 13% and 47 ± 16%, respectively, whereas they are 46 ± 17% and 45 ± 16%, respectively from the anisotropic analysis. Modeling indicates that the upper part of chimney (between 5 and 45 m below sea floor [mbsf]) is characterized by gas hydrate filling near horizontal fractures (7° dip) and the lower part of chimney (between 45 and 103 mbsf) is characterized by gas hydrate filling high angle fractures on the basis of ring resistivity and P-wave velocity. The anisotropic analysis using P40H resistivity (phase shift resistivity at 32 mHz with 40 inch spacing) and the P-wave velocity yields a gas hydrate saturation of 46 ± 15% and 46 ± 15% respectively, similar to those estimated using ring resistivity and P-wave velocity, but with quite different fracture dip angles. Differences in vertical resolution, depth of investigation, and a finite fracture dimension relative to the tool separation appear to contribute to this discrepancy. Forward modeling of anisotropic resistivity and velocity are essential to identify gas hydrate in fractures and to estimate accurate gas hydrate amounts.

  9. Self-Reported Fractures in Dermatitis Herpetiformis Compared to Coeliac Disease

    Directory of Open Access Journals (Sweden)

    Camilla Pasternack

    2018-03-01

    Full Text Available Dermatitis herpetiformis (DH is a cutaneous manifestation of coeliac disease. Increased bone fracture risk is known to associate with coeliac disease, but this has been only scantly studied in DH. In this study, self-reported fractures and fracture-associated factors in DH were investigated and compared to coeliac disease. Altogether, 222 DH patients and 129 coeliac disease-suffering controls were enrolled in this study. The Disease Related Questionnaire and the Gastrointestinal Symptom Rating Scale and Psychological General Well-Being questionnaires were mailed to participants; 45 out of 222 (20% DH patients and 35 out of 129 (27% of the coeliac disease controls had experienced at least one fracture (p = 0.140. The cumulative lifetime fracture incidence did not differ between DH and coeliac disease patients, but the cumulative incidence of fractures after diagnosis was statistically significantly higher in females with coeliac disease compared to females with DH. The DH patients and the coeliac disease controls with fractures reported more severe reflux symptoms compared to those without, and they also more frequently used proton-pump inhibitor medication. To conclude, the self-reported lifetime bone fracture risk is equal for DH and coeliac disease. After diagnosis, females with coeliac disease have a higher fracture risk than females with DH.

  10. Self-Reported Fractures in Dermatitis Herpetiformis Compared to Coeliac Disease

    Science.gov (United States)

    Pasternack, Camilla; Mansikka, Eriika; Kaukinen, Katri; Hervonen, Kaisa; Reunala, Timo; Collin, Pekka; Mattila, Ville M.

    2018-01-01

    Dermatitis herpetiformis (DH) is a cutaneous manifestation of coeliac disease. Increased bone fracture risk is known to associate with coeliac disease, but this has been only scantly studied in DH. In this study, self-reported fractures and fracture-associated factors in DH were investigated and compared to coeliac disease. Altogether, 222 DH patients and 129 coeliac disease-suffering controls were enrolled in this study. The Disease Related Questionnaire and the Gastrointestinal Symptom Rating Scale and Psychological General Well-Being questionnaires were mailed to participants; 45 out of 222 (20%) DH patients and 35 out of 129 (27%) of the coeliac disease controls had experienced at least one fracture (p = 0.140). The cumulative lifetime fracture incidence did not differ between DH and coeliac disease patients, but the cumulative incidence of fractures after diagnosis was statistically significantly higher in females with coeliac disease compared to females with DH. The DH patients and the coeliac disease controls with fractures reported more severe reflux symptoms compared to those without, and they also more frequently used proton-pump inhibitor medication. To conclude, the self-reported lifetime bone fracture risk is equal for DH and coeliac disease. After diagnosis, females with coeliac disease have a higher fracture risk than females with DH. PMID:29538319

  11. Fracture of nickel-titanium superelastic alloy in sodium hypochlorite solution

    International Nuclear Information System (INIS)

    Yokoyama, Ken'ichi; Kaneko, Kazuyuki; Yabuta, Eiji; Asaoka, Kenzo; Sakai, Jun'ichi

    2004-01-01

    Fracture of the Ni-Ti superelastic alloy for endodontic instruments such as files was investigated with a sustained tensile-loading test in sodium hypochlorite (NaOCl) solution of various concentrations. It was found that the time to fracture was reduced when the applied stress exceeded the critical stress for martensite transformation. When the applied stress was higher than the critical stress, the 0.3 mm diameter wires of the Ni-Ti superelastic alloy sometimes fractured within 60 min. From the results of observations of the fracture surface using a scanning electron microscope, it was revealed that the fracture of the Ni-Ti superelastic alloy is significantly influenced by corrosion when the applied stress was higher than the critical stress for martensite transformation. The results of the present study suggest that one of the causes of the fracture of Ni-Ti files during clinical use is corrosion under the applied stress above the critical stress for martensite transformation in NaOCl solution

  12. Cyclic fatigue resistance of RaCe and Mtwo rotary files in continuous rotation and reciprocating motion.

    Science.gov (United States)

    Vadhana, Sekar; SaravanaKarthikeyan, Balasubramanian; Nandini, Suresh; Velmurugan, Natanasabapathy

    2014-07-01

    The purpose of this study was to evaluate and compare the cyclic fatigue resistance of RaCe (FKG Dentaire, La Chaux-de-Fonds, Switzerland) and Mtwo (VDW, Munich, Germany) rotary files in continuous rotation and reciprocating motion. A total of 60 new rotary Mtwo and RaCe files (ISO size = 25, taper = 0.06, length = 25 mm) were selected and randomly divided into 4 groups (n = 15 each): Mtc (Mtwo NiTi files in continuous rotation), Rc (RaCe NiTi files in continuous rotation), Mtr (Mtwo NiTi files in reciprocating motion), and Rr (RaCe NiTi files in reciprocating motion). A cyclic fatigue testing device was fabricated with a 60° angle of curvature and a 5-mm radius. All instruments were rotated or reciprocated until fracture occurred. The time taken for each instrument to fracture and the length of the broken fragments were recorded. All the fractured files were analyzed under a scanning electron microscope to detect the mode of fracture. The Kolmogorov-Smirnov test was used to assess the normality of samples distribution, and statistical analysis was performed using the independent sample t test. The time taken for the instruments of the Mtr and Rr groups to fail under cyclic loading was significantly longer compared with the Mtc and Rc groups (P ductile mode of fracture. The length of the fractured segments was between 5 and 6 mm, which was not statistically significant among the experimental groups. Mtwo and RaCe rotary instruments showed a significantly higher cyclic fatigue resistance in reciprocating motion compared with continuous rotation motion. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  13. Enhancing in situ bioremediation with pneumatic fracturing

    International Nuclear Information System (INIS)

    Anderson, D.B.; Peyton, B.M.; Liskowitz, J.L.; Fitzgerald, C.; Schuring, J.R.

    1994-04-01

    A major technical obstacle affecting the application of in situ bioremediation is the effective distribution of nutrients to the subsurface media. Pneumatic fracturing can increase the permeability of subsurface formations through the injection of high pressure air to create horizontal fracture planes, thus enhancing macro-scale mass-transfer processes. Pneumatic fracturing technology was demonstrated at two field sites at Tinker Air Force Base, Oklahoma City, Oklahoma. Tests were performed to increase the permeability for more effective bioventing, and evaluated the potential to increase permeability and recovery of free product in low permeability soils consisting of fine grain silts, clays, and sedimentary rock. Pneumatic fracturing significantly improved formation permeability by enhancing secondary permeability and by promoting removal of excess soil moisture from the unsaturated zone. Postfracture airflows were 500% to 1,700% higher than prefracture airflows for specific fractured intervals in the formation. This corresponds to an average prefracturing permeability of 0.017 Darcy, increasing to an average of 0.32 Darcy after fracturing. Pneumatic fracturing also increased free-product recovery rates of number 2 fuel from an average of 587 L (155 gal) per month before fracturing to 1,647 L (435 gal) per month after fracturing

  14. Risk factors for equine fractures in Thoroughbred flat racing in North America.

    Science.gov (United States)

    Georgopoulos, Stamatis Panagiotis; Parkin, Tim D H

    2017-04-01

    The aim of this paper is to identify risk factors associated with equine fractures in flat horse racing of Thoroughbreds in North America. Equine fractures were defined as any fracture sustained by a horse during a race. This was a cohort study that made use of all starts from the racecourses reporting injuries. The analysis was based on 2,201,152 racing starts that represent 91% of all official racing starts in the USA and Canada from 1st January 2009-31st December 2014. Approximately 3,990,000 workout starts made by the 171,523 Thoroughbreds that raced during that period were also included in the analysis. During this period the incidence of equine fractures was 2 per 1000 starts. The final multivariable logistic regression models identified risk factors significantly associated (pfracture. For example, horses were found to have a 32% higher chance of sustaining a fracture when racing on a dirt surface compared to a synthetic surface; a 35% higher chance if they had sustained a previous injury during racing and a 47% higher chance was also found for stallions compared to mares and geldings. Furthermore, logistic regression models based on data available only from the period 2009-2013 were used to predict the probability of a Thoroughbred sustaining a fracture for 2014. The 5% of starts that had the highest score in our predictive models for 2014 were found to have 2.4 times (95% CI: 1.9-2.9) higher fracture prevalence than the mean fracture prevalence of 2014. The results of this study can be used to identify horses at higher risk on entering a race and could help inform the design and implementation of preventive measures aimed at minimising the number of Thoroughbreds sustaining fractures during racing in North America. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Quality of life following hip fractures: results from the Norwegian hip fracture register.

    Science.gov (United States)

    Gjertsen, Jan-Erik; Baste, Valborg; Fevang, Jonas M; Furnes, Ove; Engesæter, Lars Birger

    2016-07-07

    Patient-reported health-related quality of life is an important outcome measure when assessing the quality of hip fracture surgery. The frequently used EQ-5D index score has unfortunately important limitations. One alternative can be to assess the distribution of each of the five dimensions of the patients' descriptive health profile. The objective of this paper was to investigate health-related quality of life (HRQoL) after hip fractures. Data from hip fracture operations from 2005 through 2012 were obtained from The Norwegian Hip Fracture Register. Patient reported HRQoL, (EQ-5D-3L) was collected from patients preoperatively and at four and twelve months postoperatively n = 10325. At each follow-up the distribution of the EQ-5D-3L and mean pain VAS was calculated. Generally, a higher proportion of patients reported problems in all 5 dimensions of the EQ-5D-3L at all follow-ups compared to preoperative. Also a high proportion of patients with no preoperative problems reported problems after surgery; At 4 and 12 months follow-ups 71 % and 58 % of the patients reported walking problems, and 65 % and 59 % of the patients reported pain respectively. Patients with femoral neck fractures and the youngest patients (age < 70 years) reported least problems both preoperatively and at all follow-ups. A hip fracture has a dramatic impact on the patients' HRQoL, and the deterioration in HRQoL sustained also one year after the fracture. Separate use of the descriptive profile of the EQ-5D is informative when assessing quality of life after hip fracture surgery.

  16. Incidence and epidemiology of tibial shaft fractures.

    Science.gov (United States)

    Larsen, Peter; Elsoe, Rasmus; Hansen, Sandra Hope; Graven-Nielsen, Thomas; Laessoe, Uffe; Rasmussen, Sten

    2015-04-01

    The literature lacks recent population-based epidemiology studies of the incidence, trauma mechanism and fracture classification of tibial shaft fractures. The purpose of this study was to provide up-to-date information on the incidence of tibial shaft fractures in a large and complete population and report the distribution of fracture classification, trauma mechanism and patient baseline demographics. Retrospective reviews of clinical and radiological records. A total of 196 patients were treated for 198 tibial shaft fractures in the years 2009 and 2010. The mean age at time of fracture was 38.5 (21.2SD) years. The incidence of tibial shaft fracture was 16.9/100,000/year. Males have the highest incidence of 21.5/100,000/year and present with the highest frequency between the age of 10 and 20, whereas women have a frequency of 12.3/100,000/year and have the highest frequency between the age of 30 and 40. AO-type 42-A1 was the most common fracture type, representing 34% of all tibial shaft fractures. The majority of tibial shaft fractures occur during walking, indoor activity and sports. The distribution among genders shows that males present a higher frequency of fractures while participating in sports activities and walking. Women present the highest frequency of fractures while walking and during indoor activities. This study shows an incidence of 16.9/100,000/year for tibial shaft fractures. AO-type 42-A1 was the most common fracture type, representing 34% of all tibial shaft fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Risk Factors for Hip Fracture in Japanese Older Adults

    Directory of Open Access Journals (Sweden)

    Takashi Yamashita

    2012-09-01

    Full Text Available Risk factors for hip fracture in Japanese older populations are understudied compared with Western countries arguably due to the relatively lower prevalence rates in Japan. Nationally representative data from the Nihon University Japanese Longitudinal Study of Aging were analyzed using logistic regression to examine possible risk factors of hip fractures, separately for older women (n = 2,859 and older men (n = 2,108. Results showed that older Japanese women with difficulty bending their knees (OR = 1.9, with diabetes (OR = 1.7 times, and/or with more activity of daily living limitations (OR = 1.1 had higher risks of hip fracture. Older Japanese men with difficulty bending their knees (OR = 2.6, who use more external prescription drugs (OR = 1.9, and with cancer (OR = 2.0 times had higher risks of hip fracture. Further considerations of gender- and culture-specific factors along with the identified risk factors may provide insights into future intervention programs for hip fracture in Japanese older populations.

  18. Comparative evaluation of rotary ProTaper, Profile, and conventional stepback technique on reduction in Enterococcus faecalis colony-forming units and vertical root fracture resistance of root canals.

    Science.gov (United States)

    Singla, Mamta; Aggarwal, Vivek; Logani, Ajay; Shah, Naseem

    2010-03-01

    The purpose of this in vitro study was to evaluate the effect of various root canal instrumentation techniques with different instrument tapers on cleaning efficacy and resultant vertical root fracture (VRF) strength of the roots. Fifty human mandibular first premolar roots were enlarged to ISO size 20, inoculated with Enterococcus faecalis [ATCC2912] for 72 hours and divided into 5 groups: group I: prepared with .02 taper hand instruments ISO size 40; group II: Profile .04 taper size 40; group III: Profile .06 taper size 40; group IV: ProTaper size F4; and group V (control group) further divided into: Va: with bacterial inoculation and no mechanical instrumentation; and Group Vb: neither bacterial inoculation nor mechanical instrumentation. Cleaning efficacy was evaluated in terms of reduction of colony forming units (CFUs). The VRF strength was evaluated using D11 spreader as wedge in an Instron testing machine. Root canals instrumented with ProTaper and 6% Profile instruments showed maximum reduction in CFUs, with statistically insignificant difference between them. The VRF resistance decreased in all instrumented groups. The difference of VRF between 2% and 4% taper Profile groups was statistically insignificant (P = .195). One-way analysis of variance showed that canals instrumented with ProTaper F4 showed maximum reduction in VRF resistance compared with control uninstrumented group. Profile 6% taper instruments offer the advantage of maximum debridement without significant reduction in root fracture resistance. Copyright 2010 Mosby, Inc. All rights reserved.

  19. Effect of inclusion density on ductile fracture toughness and roughness

    DEFF Research Database (Denmark)

    Srivastava, Akhilesh Kumar; Ponson, L.; Osovski, S.

    2014-01-01

    Three dimensional calculations of ductile fracture under mode I plane strain, small scale yielding conditions are carried out using an elastic-viscoplastic constitutive relation for a progressively cavitating solid with two populations of void nucleating second phase particles. Larger inclusions...... that result in void nucleation at an early stage are modeled discretely while smaller particles that require large strains to nucleate voids are homogeneously distributed. Full field solutions are obtained for eight volume fractions, ranging from 1% to 19%, of randomly distributed larger inclusions. For each...... volume fraction calculations are carried out for seven random distributions of inclusion centers. Crack growth resistance curves and fracture surface roughness statistics are calculated using standard procedures. The crack growth resistance is characterized in terms of both JIC and the tearing modulus TR...

  20. The application of fracture mechanics on nodular cast iron

    International Nuclear Information System (INIS)

    Kussmaul, K.; Blind, D.; Kockelmann, H.; Roos, E.; Eisele, U.

    1987-01-01

    A series of studies on predominantly thick-walled castings was the first attempt at a characterization of the material of ferritization-annealed ductile cast iron under aspects of fracture mechanics according to today's state of fracture-mechanics research and testing. As in static and dynamic tensile testing, ferritic cast iron meeting specifications was found to be tough down -40 0 C and below in fracture mechanical testing without substantial reduction of the corresponding characteristics at room temperature; this is true for a temperature range where the lowest point of impact notch work has been reached already. Impact-type stresses with and without notching resulted in enhanced deformation resistance and deformability in the longitudinal samples taken from tubes. (orig./DG) [de

  1. Fracture risk in women with type II diabetes. Results from a historical cohort with fracture follow-up

    DEFF Research Database (Denmark)

    Holm, Jakob Præst; Jensen, Thomas; Hyldstrup, Lars

    2018-01-01

    . Prevalent fractures (43.7 vs. 33.2%, p = 0.0010) and prevalent MOF (26.2 vs. 20.5% p = 0.038) were more common among patients with type II diabetes. The unadjusted incident fracture risk was increased with a higher relative risk of 42%. An elevated MOF hazard ratio was present (HR = 1.726, p = 0.......0006). Adjustment for prevalent osteoporosis and other possible confounders did not change this finding (HR = 1.558, p = 0.0207). CONCLUSIONS: An association between type II diabetes and an increased risk of MOF primarily driven by an increased hip fracture risk was documented. This finding was independent......PURPOSE: To examine the independent association between type II diabetes and fracture risk in a population of predominantly postmenopausal women referred to a specialist clinic for osteoporosis evaluation. METHODS: Type II diabetes associated fracture risk were evaluated among to 229 patients...

  2. Sealing of rock fractures

    International Nuclear Information System (INIS)

    Pusch, R.; Erlstroem, M.; Boergesson, L.

    1985-12-01

    The major water-bearing fractures in granite usually from fairly regular sets but the extension and degree of connectivity is varying. This means that only a few fractures that are interconnected with the deposition holes and larger water-bearing structures in a HLW repository are expected and if they can be identified and cut off through sealing it would be possible to improve the isolation of waste packages very effectively. Nature's own fracture sealing mechanisms may be simulated and a survey of the involved processes actually suggests a number of possible filling methods and substances. Most of them require high temperature and pressure and correspondingly sophisticated techniques, but some are of potential interest for immediate application with rather moderate effort. Such a technique is to fill the fractures with clayey substances which stay flexible and low-permeable provided that they remain physically and chemically intact. It is demonstrated in the report that effective grouting requires a very low viscosity and shear strength of the substance and this can be achieved by mechanical agitation as demonstrated in this report. Thus, by superimposing static pressure and shear waves induced by percussion hammering at a suitable frequency, clays and fine-grained silts as well as cement can be driven into fractures with an average aperture as small as 0.1 mm. Experiments were made in the laboratory using concrete and steel plates, and a field pilot test was also conducted under realistic conditions on site in Stripa. They all demonstrated the practicality of the 'dynamic injection technique' and that the fluid condition of the grouts yielded complete filling of the injected space to a considerable distance from the injection point. The field test indicated a good sealing ability as well as a surprisingly high resistance to erosion and piping. (author)

  3. A Year of Fractures: a snapshot analysis of the logistics, problems and outcomes of a hospital-based fracture liaison service.

    Science.gov (United States)

    Vaile, J H; Sullivan, L; Connor, D; Bleasel, J F

    2013-10-01

    Our fracture liaison service identifies patients with low trauma fractures, determines the need for osteoporosis therapy and instigates therapy if necessary. We describe the tracking and outcome of 768 patients attending our emergency department over 1 year and discuss the problems we encountered and potential solutions. Osteoporotic fractures result in substantial morbidity, mortality and economic cost, and patients sustaining a first fracture are known to be at higher risk of sustaining future fracture. Treatment of at-risk patients has been shown to assist in prevention of future fracture including hip fracture. We established a "First Fracture Project" to identify and treat these patients in 2003. We assessed "A Year of Fractures": the logistics, outcome and problems in tracking patients presenting to our emergency department with a low trauma fracture by our fracture liaison service, over 1 year from July 2008 to June 2009. Patients were tracked by our osteoporosis nurse and offered assessment, and treatment where necessary. In 1 year, 768 patients aged 50 or over were identified from emergency department records as attending with a low trauma fracture. About 84 % of patients eventually received assessment. Of the162 patients progressing through the entire process, 74 % had osteoporosis treatment planned and/or commenced. Our fracture liaison service was effective at identifying most low trauma fracture patients at risk of further fracture and providing access to osteoporosis assessment. There were many difficulties: we outline logistic and practical issues in delivering our service and suggest potential improvements.

  4. Insulating materials resistance in intense radiation beams

    International Nuclear Information System (INIS)

    Oproiu, Constantin; Martin, Diana; Scarlat, Florin; Timus, Dan; Brasoveanu, Mirela; Nemtanu, Monica

    2002-01-01

    The paper emphasizes the main changes of the mechanical and electrical properties of some organic insulating materials exposed to accelerated electron beams. These materials are liable to be used in nuclear plants and particle accelerators. The principal mechanical and electrical properties analyzed were: tensile strength, fracture strength, tearing on fracture, dielectric strength, electrical resistivity, dielectric constant and tangent angle of dielectric losses. (authors)

  5. Elastic-plastic fracture mechanics of compact bone

    Science.gov (United States)

    Yan, Jiahau

    Bone is a composite composed mainly of organics, minerals and water. Most studies on the fracture toughness of bone have been conducted at room temperature. Considering that the body temperature of animals is higher than room temperature, and that bone has a high volumetric percentage of organics (generally, 35--50%), the effect of temperature on fracture toughness of bone should be studied. Single-edged V-shaped notched (SEVN) specimens were prepared to measure the fracture toughness of bovine femur and manatee rib in water at 0, 10, 23, 37 and 50°C. The fracture toughness of bovine femur and manatee rib were found to decrease from 7.0 to 4.3 MPa·m1/2 and from 5.5 to 4.1 MPa·m1/2, respectively, over a temperature range of 50°C. The decreases were attributed to inability of the organics to sustain greater stresses at higher temperatures. We studied the effects of water and organics on fracture toughness of bone using water-free and organics-free SEVN specimens at 23°C. Water-free and organics-free specimens were obtained by placing fresh bone specimen in a furnace at different temperatures. Water and organics significantly affected the fracture toughness of bone. Fracture toughness of the water-free specimens was 44.7% (bovine femur) and 32.4% (manatee rib) less than that of fresh-bone specimens. Fracture toughness of the organics-free specimens was 92.7% (bovine femur) and 91.5% (manatee rib) less than that of fresh bone specimens. Linear Elastic Fracture Mechanics (LEFM) is widely used to study bone. However, bone often has small to moderate scale yielding during testing. We used J integral, an elastic-plastic fracture-mechanics parameter, to study the fracture process of bone. The J integral of bovine femur increased from 6.3 KJ/mm2 at 23°C to 6.7 KJ/mm2 at 37°C. Although the fracture toughness of bovine bone decreases as the temperature increases, the J integral results show a contrary trend. The energy spent in advancing the crack beyond the linear

  6. Validation of fragility fractures in primary care electronic medical records: A population-based study.

    Science.gov (United States)

    Martinez-Laguna, Daniel; Soria-Castro, Alberto; Carbonell-Abella, Cristina; Orozco-López, Pilar; Estrada-Laza, Pilar; Nogues, Xavier; Díez-Perez, Adolfo; Prieto-Alhambra, Daniel

    2017-11-28

    Electronic medical records databases use pre-specified lists of diagnostic codes to identify fractures. These codes, however, are not specific enough to disentangle traumatic from fragility-related fractures. We report on the proportion of fragility fractures identified in a random sample of coded fractures in SIDIAP. Patients≥50 years old with any fracture recorded in 2012 (as per pre-specified ICD-10 codes) and alive at the time of recruitment were eligible for this retrospective observational study in 6 primary care centres contributing to the SIDIAP database (www.sidiap.org). Those with previous fracture/s, non-responders, and those with dementia or a serious psychiatric disease were excluded. Data on fracture type (traumatic vs fragility), skeletal site, and basic patient characteristics were collected. Of 491/616 (79.7%) patients with a registered fracture in 2012 who were contacted, 331 (349 fractures) were included. The most common fractures were forearm (82), ribs (38), and humerus (32), and 225/349 (64.5%) were fragility fractures, with higher proportions for classic osteoporotic sites: hip, 91.7%; spine, 87.7%; and major fractures, 80.5%. This proportion was higher in women, the elderly, and patients with a previously coded diagnosis of osteoporosis. More than 4 in 5 major fractures recorded in SIDIAP are due to fragility (non-traumatic), with higher proportions for hip (92%) and vertebral (88%) fracture, and a lower proportion for fractures other than major ones. Our data support the validity of SIDIAP for the study of the epidemiology of osteoporotic fractures. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  7. Fracture toughness in metal matrix composites

    Directory of Open Access Journals (Sweden)

    Perez Ipiña J.E.

    2000-01-01

    Full Text Available Evaluations of the fracture toughness in metal matrix composites (Duralcan reinforced with 15% of Al(20(3 and SiC are presented in this work. The application of Elastic Plastic Fracture Mechanics is discussed and the obtained values are compared with the ones obtained by means of Linear Elastic Fracture Mechanics. Results show that J IC derived K JC values are higher than the corresponding values obtained by direct application of the linear elastic methodology. The effect of a heat treatment on the material fracture toughness was also evaluated in which the analyzed approaches showed, not only different toughness values, but also opposite tendencies. A second comparison of the J IC and K JC values obtained in this work with toughness values reported in the literature is presented and discussed.

  8. The application of ductile-fracture analysis to predictions of pressure-tube failure

    International Nuclear Information System (INIS)

    Simpson, L.A.

    1981-08-01

    Progress during the past six years towards establishing a method for predicting critical crack length in a reactor pressure tube, based on data from tests on small fracture-mechanics specimens, is reviewed. The disadvantages of relying on data from burst tests alone are described along with the benefits of a small-specimen method. It is clear from the work reviewed that only an approach that can account for the ability of the presssure tube material to increase its crack-growth resistance during stable crack extension is suitable for the prediction of critical crack length. A method that utilizes crack-growth resistance curves based on crack-opening displacement, or the J integral, is described, along with a large body of experimental data. It is concluded that the resistance curve approach provides a viable method for the analysis of fracture in pressure tubes that can greatly improve our understanding of the material's behaviour

  9. Effects of through-the-thickness stitching on impact and interlaminar fracture properties of textile graphite/epoxy laminates

    Science.gov (United States)

    Sharma, Suresh K.; Sankar, Bhavani V.

    1995-01-01

    This study investigated the effects of through-the-thickness stitching on impact damage resistance, impact damage tolerance, and mode I and mode II fracture toughness of textile graphite/epoxy laminates. Uniweave resin-transfer-molded 48 ply graphite/epoxy (AS4/3501-6) laminates were stitched with Kevlar and glass yarns of different linear densities and stitch spacings. Delaminations were implanted during processing to simulate impact damage. Sublaminate buckling tests were performed to determine the effects of stitching on the compressive strength. The results showed outstanding improvements of up to 400 percent in the compression strength over the unstitched laminates. In impact and static indentation tests the onset of damage occurred at the same level, but the extent of damage was less in stitched laminates. Mode I fracture toughness of 24 ply Uniweave unidirectional (AS4/3501-6) stitched laminates was measured by conducting double-cantilever-beam tests. The critical strain energy release rate (G(sub Ic)) was found to be up to 30 times higher than the unstitched laminates. Mode II fracture toughness of the Uniweave laminates was measured by performing end-notched-flexure tests. Two new methods to compute the apparent G(sub IIc) are presented. The apparent G(sub IIc) was found to be at least 5-15 times higher for the stitched laminates.

  10. Ball-joint versus single monolateral external fixators for definitive treatment of tibial shaft fractures.

    Science.gov (United States)

    Beltsios, Michail; Mavrogenis, Andreas F; Savvidou, Olga D; Karamanis, Eirineos; Kokkalis, Zinon T; Papagelopoulos, Panayiotis J

    2014-07-01

    To compare modular monolateral external fixators with single monolateral external fixators for the treatment of open and complex tibial shaft fractures, to determine the optimal construct for fracture union. A total of 223 tibial shaft fractures in 212 patients were treated with a monolateral external fixator from 2005 to 2011; 112 fractures were treated with a modular external fixator with ball-joints (group A), and 111 fractures were treated with a single external fixator without ball-joints (group B). The mean follow-up was 2.9 years. We retrospectively evaluated the operative time for fracture reduction with the external fixator, pain and range of motion of the knee and ankle joints, time to union, rate of malunion, reoperations and revisions of the external fixators, and complications. The time for fracture reduction was statistically higher in group B; the rate of union was statistically higher in group B; the rate of nonunion was statistically higher in group A; the mean time to union was statistically higher in group A; the rate of reoperations was statistically higher in group A; and the rate of revision of the external fixator was statistically higher in group A. Pain, range of motion of the knee and ankle joints, rates of delayed union, malunion and complications were similar. Although modular external fixators are associated with faster intraoperative fracture reduction with the external fixator, single external fixators are associated with significantly better rates of union and reoperations; the rates of delayed union, malunion and complications are similar.

  11. Intrinsic material property differences in bone tissue from patients suffering low-trauma osteoporotic fractures, compared to matched non-fracturing women.

    Science.gov (United States)

    Vennin, S; Desyatova, A; Turner, J A; Watson, P A; Lappe, J M; Recker, R R; Akhter, M P

    2017-04-01

    Osteoporotic (low-trauma) fractures are a significant public health problem. Over 50% of women over 50yrs. of age will suffer an osteoporotic fracture in their remaining lifetimes. While current therapies reduce skeletal fracture risk by maintaining or increasing bone density, additional information is needed that includes the intrinsic material strength properties of bone tissue to help develop better treatments, since measurements of bone density account for no more than ~50% of fracture risk. The hypothesis tested here is that postmenopausal women who have sustained osteoporotic fractures have reduced bone quality, as indicated with measures of intrinsic material properties compared to those who have not fractured. Transiliac biopsies (N=120) were collected from fracturing (N=60, Cases) and non-fracturing postmenopausal women (N=60, age- and BMD-matched Controls) to measure intrinsic material properties using the nano-indentation technique. Each biopsy specimen was embedded in epoxy resin and then ground, polished and used for the nano-indentation testing. After calibration, multiple indentations were made using quasi-static (hardness, modulus) and dynamic (storage and loss moduli) testing protocols. Multiple indentations allowed the median and variance to be computed for each type of measurement for each specimen. Cases were found to have significantly lower median values for cortical hardness and indentation modulus. In addition, cases showed significantly less within-specimen variability in cortical modulus, cortical hardness, cortical storage modulus and trabecular hardness, and more within-specimen variability in trabecular loss modulus. Multivariate modeling indicated the presence of significant independent mechanical effects of cortical loss modulus, along with variability of cortical storage modulus, cortical loss modulus, and trabecular hardness. These results suggest mechanical heterogeneity of bone tissue may contribute to fracture resistance

  12. Cyclic Fatigue Resistance of OneShape, HyFlex EDM, WaveOne Gold, and Reciproc Blue Nickel-titanium Instruments.

    Science.gov (United States)

    Gündoğar, Mustafa; Özyürek, Taha

    2017-07-01

    The purpose of this study was to compare the cyclic fatigue resistances of Reciproc Blue (VDW, Munich, Germany), HyFlex EDM (Coltene/Whaledent, Altstätten, Switzerland), WaveOne Gold (Dentsply Maillefer, Ballaigues, Switzerland), and OneShape (Micro Mega, Besancon, France) single-file NiTi systems. Thirty Reciproc Blue R25 (25/.08), 30 HyFlex EDM (25/.∼), 30 WaveOne Gold Primary (25/.07), and 30 OneShape (25/.06) instruments were included in this study. All the instruments were rotated in artificial canals, which were made of stainless steel with an inner diameter of 1.5 mm, a 60° angle of curvature, and radii of curvatures of 5 mm until fracture occurred, and the time to fracture was recorded in seconds using a digital chronometer. The data were analyzed statistically using Kruskal-Wallis and post hoc Dunn tests via SPSS 21.0 software (SPSS Inc, Chicago, IL). The statistical significance level was set at 5%. The HyFlex EDM file (3456.33 ± 633.37) file had the statistically highest fatigue resistance, and the OneShape file (1221.63 ± 812.4) had the least fatigue resistance (P  .05) in the mean length of the fractured fragments of the files (P > .05). Within the limitations of the present in vitro study, it was found that cyclic fatigue resistance of HyFlex EDM files was higher than the cyclic fatigue resistances of OneShape, Reciproc Blue, and WaveOne Gold files. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  13. Effects of stitching on fracture toughness of uniweave textile graphite/epoxy laminates

    Science.gov (United States)

    Sankar, Bhavani V.; Sharma, Suresh

    1995-01-01

    The effects of through-the-thickness stitching on impact damage resistance, impact damage tolerance, and Mode 1 and Mode 2 fracture toughness of textile graphite/epoxy laminates were studied experimentally. Graphite/epoxy laminates were fabricated from AS4 graphite uniweave textiles and 3501-6 epoxy using Resin Transfer Molding. The cloths were stitched with Kevlar(tm) and glass yarns before resin infusion. Delamination was implanted during processing to simulate impact damage. Sublaminate buckling tests were performed in a novel fixture to measure Compression After Impact (CAI) strength of stitched laminates. The results show that CAI strength can be improved up to 400% by through-the-thickness stitching. Double Cantilever Beam tests were performed to study the effect of stitching on Mode 1 fracture toughness G(sub 1c). It was found that G(sub 1c) increased 30 times for a low stitching density of 16 stitches/sq in. Mode 2 fracture toughness was measured by testing the stitched beams in End Notch Flexure tests. Unlike in the unstitiched beams, crack propagation in the stitched beams was steady. The current formulas for ENF tests were not found suitable for determining G(sub 2C) for stitched beams. Hence two new methods were developed - one based on crack area measured from ultrasonic C-scanning and the other based on equivalent crack area measured from the residual stiffness of the specimen. The G(sub 2c) was found to be at least 5-15 times higher for the stitched laminates. The mechanisms by which stitching increases the CAI strength and fracture toughness are discussed.

  14. Inferring biological evolution from fracture patterns in teeth.

    Science.gov (United States)

    Lawn, Brian R; Bush, Mark B; Barani, Amir; Constantino, Paul J; Wroe, Stephen

    2013-12-07

    It is hypothesised that specific tooth forms are adapted to resist fracture, in order to accommodate the high bite forces needed to secure, break down and consume food. Three distinct modes of tooth fracture are identified: longitudinal fracture, where cracks run vertically between the occlusal contact and the crown margin (or vice versa) within the enamel side wall; chipping fracture, where cracks run from near the edge of the occlusal surface to form a spall in the enamel at the side wall; and transverse fracture, where a crack runs horizontally through the entire section of the tooth to break off a fragment and expose the inner pulp. Explicit equations are presented expressing critical bite force for each fracture mode in terms of characteristic tooth dimensions. Distinctive transitions between modes occur depending on tooth form and size, and loading location and direction. Attention is focussed on the relatively flat, low-crowned molars of omnivorous mammals, including humans and other hominins and the elongate canines of living carnivores. At the same time, allusion to other tooth forms - the canines of the extinct sabre-tooth (Smilodon fatalis), the conical dentition of reptiles, and the columnar teeth of herbivores - is made to highlight the generality of the methodology. How these considerations impact on dietary behaviour in fossil and living taxa is discussed. © 2013 Elsevier Ltd. All rights reserved.

  15. Model of T-Type Fracture in Coal Fracturing and Analysis of Influence Factors of Fracture Morphology

    Directory of Open Access Journals (Sweden)

    Yuwei Li

    2018-05-01

    Full Text Available Special T-type fractures can be formed when coal is hydraulically fractured and there is currently no relevant theoretical model to calculate and describe them. This paper first establishes the height calculation model of vertical fractures in multi-layered formations and deduces the stress intensity factor (SIF at the upper and lower sides of the fracture in the process of vertical fracture extension. Combined with the fracture tip stress analysis method of fracture mechanics theory, the horizontal bedding is taken into account for tensile and shear failure, and the critical mechanical conditions for the formation of horizontal fracture in coal are obtained. Finally, the model of T-type fracture in coal fracturing is established, and it is verified by fracturing simulation experiments. The model calculation result shows that the increase of vertical fracture height facilitates the increase of horizontal fracture length. The fracture toughness of coal has a significant influence on the length of horizontal fracture and there is a threshold. When the fracture toughness is less than the threshold, the length of horizontal fracture remains unchanged, otherwise, the length of horizontal fracture increases rapidly with the increase of fracture toughness. When the shear strength of the interface between the coalbed and the interlayer increases, the length of the horizontal fracture of the T-type fracture rapidly decreases.

  16. Radiation Induced Rib Fractures on Bone Scan after Breast Cancer Surgery and Radiation Therapy

    International Nuclear Information System (INIS)

    Kim, Hae Won; Won, Kyoung Sook; Zeon, Seok Kil; Kim, Jin Hee

    2009-01-01

    This study is to evaluate rib fractures on bone scan in breast cancer patients treated with breast cancer surgery and radiation therapy and to evaluate its relation with radiation therapy and operation modality. Two hundred seventy cases that underwent serial bone scan after breast cancer surgery and radiation therapy were enrolled. Bone scan and chest CT findings of rib fracture were analyzed. The rib uptake was seen in 74 of 270 cases (27.4%) on bone scan and 50 cases (18.5%) were confirmed to have rib fracture by chest CT. The rate of modified radical mastectomy in patients with rib fracture was significantly higher than that in patients without rib fracture (66.0% vs. 27.0%, p=0.000). The rate of additional radiation therapy to axillar or supraclavicular regions in patients with rib fracture was significantly higher than that in patients without rib fracture (62.0% vs. 28.6%, p=0.000). Rib fracture was seen most frequently at 1-2 years after radiation therapy (51.9%) and single rib fracture was seen most frequently (55.2%). Of total 106 rib fractures, focal rib uptake was seen in 94 ribs (88.7%) and diffuse rib uptake was seen in 12 ribs (11.3%). On one year follow-up bone scan, complete resolution of rib uptake was seen in 15 ribs (14.2%). On chest CT, the rate of fracture line in ribs with intense uptake was significantly higher than that in ribs with mild or moderate uptake (p=0.000). The rate of presence of fracture line in ribs with focal uptake was significantly higher than that in ribs with diffuse uptake (p=0.001). Rib fracture in breast cancer patients after radiation therapy was related to radiation portal and operation modality. It should be interpreted carefully as a differential diagnosis of bone metastasis

  17. Radiation Induced Rib Fractures on Bone Scan after Breast Cancer Surgery and Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hae Won; Won, Kyoung Sook; Zeon, Seok Kil; Kim, Jin Hee [Keimyung University, School of Medicine, Daegu (Korea, Republic of)

    2009-08-15

    This study is to evaluate rib fractures on bone scan in breast cancer patients treated with breast cancer surgery and radiation therapy and to evaluate its relation with radiation therapy and operation modality. Two hundred seventy cases that underwent serial bone scan after breast cancer surgery and radiation therapy were enrolled. Bone scan and chest CT findings of rib fracture were analyzed. The rib uptake was seen in 74 of 270 cases (27.4%) on bone scan and 50 cases (18.5%) were confirmed to have rib fracture by chest CT. The rate of modified radical mastectomy in patients with rib fracture was significantly higher than that in patients without rib fracture (66.0% vs. 27.0%, p=0.000). The rate of additional radiation therapy to axillar or supraclavicular regions in patients with rib fracture was significantly higher than that in patients without rib fracture (62.0% vs. 28.6%, p=0.000). Rib fracture was seen most frequently at 1-2 years after radiation therapy (51.9%) and single rib fracture was seen most frequently (55.2%). Of total 106 rib fractures, focal rib uptake was seen in 94 ribs (88.7%) and diffuse rib uptake was seen in 12 ribs (11.3%). On one year follow-up bone scan, complete resolution of rib uptake was seen in 15 ribs (14.2%). On chest CT, the rate of fracture line in ribs with intense uptake was significantly higher than that in ribs with mild or moderate uptake (p=0.000). The rate of presence of fracture line in ribs with focal uptake was significantly higher than that in ribs with diffuse uptake (p=0.001). Rib fracture in breast cancer patients after radiation therapy was related to radiation portal and operation modality. It should be interpreted carefully as a differential diagnosis of bone metastasis.

  18. Effects of HIP and forging on fracture behaviour in cast iron with spheroidal vanadium carbides dispersed within martensitic-matrix microstructure

    International Nuclear Information System (INIS)

    Uematsu, Y.; Tokaji, K.; Nishigaki, K.; Okajima, D.; Ogasawara, M.

    2010-01-01

    The cast iron with spheroidal vanadium carbides dispersed within martensitic-matrix microstructure was developed as a die material due to its high hardness. In order to achieve high performances of dies, not only the hardness but also the mechanical properties such as fracture toughness and fatigue crack propagation (FCP) resistance should be improved. In this paper, hot isostatic pressing (HIP) or forging was applied to the cast iron to improve mechanical properties, and the fracture behaviour, such as flexural strength, fracture toughness and FCP, was studied. The average flexural strength was reduced by forging because of the enhanced notch sensitivity due to the increase in the hardness. The fracture toughness was not affected by HIP nor forging while its scatter was significantly reduced by both post-treatments. The intrinsic FCP resistance taking account of crack closure was the same regardless of the application of HIP or forging, indicating that a slight change in the microstructure resulting from both treatments and the presence of casting defects exerted little influence on FCP behaviour. It could be concluded that both HIP and forging could improve the hardness of the material, while fracture toughness and FCP resistance were maintained.

  19. Fluid driven fracture mechanics in highly anisotropic shale: a laboratory study with application to hydraulic fracturing

    Science.gov (United States)

    Gehne, Stephan; Benson, Philip; Koor, Nick; Enfield, Mark

    2017-04-01

    direction of σ1. Conversely, the crack plane develops perpendicular to the bedding plane, if the bedding plane is orientated normal to σ1. Fracture initiation pressures are higher in the Divider orientation ( 24MPa) than in the Short-Transverse orientation ( 14MPa) showing a tensile strength anisotropy ( 42%) comparable to ambient tensile strength results. We then use X-Ray Computed Tomography (CT) 3D-images to evaluate the evolved fracture network in terms of fracture pattern, aperture and post-test water permeability. For both fracture orientations, very fine, axial fractures evolve over the entire length of the sample. For the fracturing in the Divider orientation, it has been observed, that in some cases, secondary fractures are branching of the main fracture. Test data from fluid driven fracturing experiments suggest that fracture pattern, fracture propagation trajectories and fracturing fluid pressure (initiation and propagation pressure) are predominantly controlled by the interaction between the anisotropic mechanical properties of the shale and the anisotropic stress environment. The orientation of inherent rock anisotropy relative to the principal stress directions seems to be the main control on fracture orientation and required fracturing pressure.

  20. Gender-specific hip fracture risk in community-dwelling and institutionalized seniors age 65 years and older.

    Science.gov (United States)

    Finsterwald, M; Sidelnikov, E; Orav, E J; Dawson-Hughes, B; Theiler, R; Egli, A; Platz, A; Simmen, H P; Meier, C; Grob, D; Beck, S; Stähelin, H B; Bischoff-Ferrari, H A

    2014-01-01

    In this study of acute hip fracture patients, we show that hip fracture rates differ by gender between community-dwelling seniors and seniors residing in nursing homes. While women have a significantly higher rate of hip fracture among the community-dwelling seniors, men have a significantly higher rate among nursing home residents. Differences in gender-specific hip fracture risk between community-dwelling and institutionalized seniors have not been well established, and seasonality of hip fracture risk has been controversial. We analyzed detailed data from 1,084 hip fracture patients age 65 years and older admitted to one large hospital center in Zurich, Switzerland. In a sensitivity analysis, we extend to de-personalized data from 1,265 hip fracture patients from the other two large hospital centers in Zurich within the same time frame (total n = 2,349). The denominators were person-times accumulated by the Zurich population in the corresponding age/gender/type of dwelling stratum in each calendar season for the period of the study. In the primary analysis of 1,084 hip fracture patients (mean age 85.1 years; 78% women): Among community-dwelling seniors, the risk of hip fracture was twofold higher among women compared with men (RR = 2.16; 95% CI, 1.74-2.69) independent of age, season, number of comorbidities, and cognitive function; among institutionalized seniors, the risk of hip fracture was 26% lower among women compared with men (RR = 0.77; 95% CI: 0.63-0.95) adjusting for the same confounders. In the sensitivity analysis of 2,349 hip fracture patients (mean age 85.0 years, 76% women), this pattern remained largely unchanged. There is no seasonal swing in hip fracture incidence. We confirm for seniors living in the community that women have a higher risk of hip fracture than men. However, among institutionalized seniors, men are at higher risk for hip fracture.

  1. Comparison in bone turnover markers during early healing of femoral neck fracture and trochanteric fracture in elderly patients

    Directory of Open Access Journals (Sweden)

    Shota Ikegami

    2009-10-01

    Full Text Available Healing of fractures is different for each bone and bone turnover markers may reflect the fracture healing process. The purpose of this study was to determine the characteristic changes in bone turnover markers during the fracture healing process. The subjects were consecutive patients with femoral neck or trochanteric fracture who underwent surgery and achieved bone union. There were a total of 39 patients, including 33 women and 6 men. There were 18 patients (16 women and 2 men with femoral neck fracture and 21 patients (17 women and 4 men with trochanteric fracture. Serum bone-specific alkaline phosphatase (BAP was measured as a bone formation marker. Urine and serum levels of N-terminal telopeptide of type I collagen (NTX, as well as urine levels of C-terminal telopeptide of type I collagen (CTX and deoxypyridinoline (DPD, were measured as markers of bone resorption. All bone turnover markers showed similar changes in patients with either type of fracture, but significantly higher levels of both bone formation and resorption markers were observed in trochanteric fracture patients than in neck fracture patients. BAP showed similar levels at one week after surgery and then increased. Bone resorption markers were increased after surgery in patients with either fracture. The markers reached their peak values at three weeks (BAP and urinary NTX, five weeks (serum NTX and DPD, and 2-3 weeks (CTX after surgery. The increase in bone turnover markers after hip fracture surgery and the subsequent decrease may reflect increased bone formation and remodeling during the healing process. Both fractures had a similar bone turnover marker profile, but the extent of the changes differed between femoral neck and trochanteric fractures.

  2. Comparison in bone turnover markers during early healing of femoral neck fracture and trochanteric fracture in elderly patients.

    Science.gov (United States)

    Ikegami, Shota; Kamimura, Mikio; Nakagawa, Hiroyuki; Takahara, Kenji; Hashidate, Hiroyuki; Uchiyama, Shigeharu; Kato, Hiroyuki

    2009-10-10

    Healing of fractures is different for each bone and bone turnover markers may reflect the fracture healing process. The purpose of this study was to determine the characteristic changes in bone turnover markers during the fracture healing process. The subjects were consecutive patients with femoral neck or trochanteric fracture who underwent surgery and achieved bone union. There were a total of 39 patients, including 33 women and 6 men. There were 18 patients (16 women and 2 men) with femoral neck fracture and 21 patients (17 women and 4 men) with trochanteric fracture. Serum bone-specific alkaline phosphatase (BAP) was measured as a bone formation marker. Urine and serum levels of N-terminal telopeptide of type I collagen (NTX), as well as urine levels of C-terminal telopeptide of type I collagen (CTX) and deoxypyridinoline (DPD), were measured as markers of bone resorption. All bone turnover markers showed similar changes in patients with either type of fracture, but significantly higher levels of both bone formation and resorption markers were observed in trochanteric fracture patients than in neck fracture patients. BAP showed similar levels at one week after surgery and then increased. Bone resorption markers were increased after surgery in patients with either fracture. The markers reached their peak values at three weeks (BAP and urinary NTX), five weeks (serum NTX and DPD), and 2-3 weeks (CTX) after surgery. The increase in bone turnover markers after hip fracture surgery and the subsequent decrease may reflect increased bone formation and remodeling during the healing process. Both fractures had a similar bone turnover marker profile, but the extent of the changes differed between femoral neck and trochanteric fractures.

  3. Is human fracture hematoma inherently angiogenic?

    LENUS (Irish Health Repository)

    Street, J

    2012-02-03

    This study attempts to explain the cellular events characterizing the changes seen in the medullary callus adjacent to the interfragmentary hematoma during the early stages of fracture healing. It also shows that human fracture hematoma contains the angiogenic cytokine vascular endothelial growth factor and has the inherent capability to induce angiogenesis and thus promote revascularization during bone repair. Patients undergoing emergency surgery for isolated bony injury were studied. Raised circulating levels of vascular endothelial growth factor were seen in all injured patients, whereas the fracture hematoma contained significantly higher levels of vascular endothelial growth factor than did plasma from these injured patients. However, incubation of endothelial cells in fracture hematoma supernatant significantly inhibited the in vitro angiogenic parameters of endothelial cell proliferation and microtubule formation. These phenomena are dependent on a local biochemical milieu that does not support cytokinesis. The hematoma potassium concentration is cytotoxic to endothelial cells and osteoblasts. Subcutaneous transplantation of the fracture hematoma into a murine wound model resulted in new blood vessel formation after hematoma resorption. This angiogenic effect is mediated by the significant concentrations of vascular endothelial growth factor found in the hematoma. This study identifies an angiogenic cytokine involved in human fracture healing and shows that fracture hematoma is inherently angiogenic. The differences between the in vitro and in vivo findings may explain the phenomenon of interfragmentary hematoma organization and resorption that precedes fracture revascularization.

  4. Postirradiation fracture toughness of Inconel X-750

    International Nuclear Information System (INIS)

    Mills, W.J.

    1983-01-01

    The effect of fast-neutron irradiation on the fracture toughness response of Inconel X-750 was characterized at 427 deg C using the J-R curve technique. Irradiation exposures ranging from 3 to 16 displacements per atom resulted in a reduction in Jsub(Ic) from 130 to 76 kJ/m 2 and a reduction in tearing modulus from 32 to 2.6. Postirradiation fractographic examination revealed that an intergranular fracture mechanism was dominant, in contrast to the extensive transgranular cracking mode found on unirradiated fracture surfaces. The enhanced intergranular failure observed after irradiation was caused by extensive heterogeneous slip in a matrix that was greatly strengthened by an irradiation-induced dislocation substructure. Specifically, intense planar slip bands impinged on the grain boundaries and generated large stress concentrations. Since the stress concentrations could not be relaxed by the hardened matrix, the grain boundaries 'unzipped' readily, resulting in the low toughness and tearing resistance. (author)

  5. Strain-based fracture assessment of pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Olsoe, Erlend; Oestby, Erling; Nyhus, Baard [SINTEF, Trondheim (Norway); Skallerud, Bjoern; Holthe, Kjell [Norwegian University of Science and Technology (NTNU), Trondheim (Norway); Berg, Espen [LINKftr AS, Trondheim (Norway)

    2009-12-19

    The oil and gas industry moves into harsher regions and faces challenges with i.e. deep water, arctic conditions and seismic regions. Consequently, ensuring the integrity of pipelines becomes more challenging, and potential large deformation scenarios that can be attributed to the above mentioned areas have lead to a current strong focus on strain-based fracture assessment methods for pipelines. However, no widely established methods exist today. In this paper specific challenges related to development of such methods are discussed. Keywords are biaxial loading, crack driving force relations, ductile tearing resistance, and definition of strain capacity. The effect of the different features will be illustrated with both experimental and numerical simulation results. Experimental results presented will cover both large- and small-scale testing. A highly efficient and accurate line-spring based numerical fracture assessment method will be presented. A simplified scheme for a strain-based fracture assessment method will also be briefly outlined, and the extension of this method to also include partial safety factors is discussed. (author)

  6. Fractures and the increased risk of suicide.

    Science.gov (United States)

    Chang, C-F; Lai, E C-C; Yeh, M-K

    2018-06-01

    Aims A high rate of suicide has been reported in patients who sustain fractures, but the association remains uncertain in the context of other factors. The aim of this study was to examine the association between fractures and the risk of suicide in this contextual setting. Patients and Methods We performed a case-control study of patients aged 40 years or older who died by suicide between 2000 and 2011. We included patients' demographics, physical and mental health problems, and socioeconomic factors. We performed conditional logistic regression to evaluate the associations between fractures and the risk of suicide. Results We included a total of 34 794 patients who died by suicide and 139 176 control patients. We found that fractures as a homogenous group (adjusted odds ratios (aOR), 1.48; 95% confidence interval (CI) 1.43 to 1.53), and specifically pelvic (aOR 2.04; 95% CI 1.68 to 2.47) and spinal fractures (aOR 1.53; 95% CI 1.43 to 1.64), were associated with a higher risk of suicide. In addition, we found that patients who had a lower income, had never married, had lower levels of educational attainment, or had coexistent physical and mental conditions such as anxiety, mood disorders, and psychosis-related disorders had a higher risk of suicide. Conclusion Fractures, specifically those of the hip and spine, were associated with an increased risk of suicide. The findings suggest that greater clinical attention should be given to this risk in patients with fractures, especially for those with additional risk factors. Cite this article: Bone Joint J 2018;100-B:780-6.

  7. [An in vitro study of the fracture strength of tooth preparations for Empress 2 veneers and crowns and mandibular incisors restored with Empress 2 veneers and crowns].

    Science.gov (United States)

    Wei, Xue; Li, Yan

    2009-12-01

    To compare the fracture resistance of mandibular incisors' preparations for veneers and crowns, mandibular incisors restored with Empress 2 veneers and crowns. 50 human mandibular incisors were randomly divided into five groups. Each group consisted of ten teeth and the treatment obtained as follows: A, tooth preparations for veneers; B, tooth preparations for crowns; C, teeth restored with veneers; D, teeth restored with crowns; E, untreated group. The teeth received standardized preparation and the restorations were manufactured with Empress 2 system and cemented with resin luting agent. The fracture resistances of teeth were measured by Instron universal testing machine and statistically analyzed with one-way ANOVA. The fracture resistances of A, B, C, D, E were (576.11 +/- 91.53), (204.13 +/- 85.88), (451.50 +/- 116.81), (386.16 +/- 117.75) and (566.05 +/- 121.37) N, respectively. The statistical analysis demonstrated significant differences between five groups. There were no significant differences between group A and E, group C and D. Tooth preparations for veneers did not significantly reduce the fracture resistance of mandibular incisor. The fracture resistance of teeth restored with Empress 2 veneers and crowns did not significantly differ from each other.

  8. Micromechanics-Based Damage Analysis of Fracture in Ti5553 Alloy with Application to Bolted Sectors

    Science.gov (United States)

    Bettaieb, Mohamed Ben; Van Hoof, Thibaut; Minnebo, Hans; Pardoen, Thomas; Dufour, Philippe; Jacques, Pascal J.; Habraken, Anne Marie

    2015-03-01

    A physics-based, uncoupled damage model is calibrated using cylindrical notched round tensile specimens made of Ti5553 and Ti-6Al-4V alloys. The fracture strain of Ti5553 is lower than for Ti-6Al-4V in the full range of stress triaxiality. This lower ductility originates from a higher volume fraction of damage sites. By proper heat treatment, the fracture strain of Ti5553 increases by almost a factor of two, as a result of a larger damage nucleation stress. This result proves the potential for further optimization of the damage resistance of the Ti5553 alloy. The damage model is combined with an elastoviscoplastic law in order to predict failure in a wide range of loading conditions. In particular, a specific application involving bolted sectors is addressed in order to determine the potential of replacing the Ti-6Al-4V by the Ti5553 alloy.

  9. A quasi steady state method for solving transient Darcy flow in complex 3D fractured networks accounting for matrix to fracture flow

    Science.gov (United States)

    Nœtinger, B.

    2015-02-01

    Modeling natural Discrete Fracture Networks (DFN) receives more and more attention in applied geosciences, from oil and gas industry, to geothermal recovery and aquifer management. The fractures may be either natural, or artificial in case of well stimulation. Accounting for the flow inside the fracture network, and accounting for the transfers between the matrix and the fractures, with the same level of accuracy is an important issue for calibrating the well architecture and for setting up optimal resources recovery strategies. Recently, we proposed an original method allowing to model transient pressure diffusion in the fracture network only [1]. The matrix was assumed to be impervious. A systematic approximation scheme was built, allowing to model the initial DFN by a set of N unknowns located at each identified intersection between fractures. The higher N, the higher the accuracy of the model. The main assumption was using a quasi steady state hypothesis, that states that the characteristic diffusion time over one single fracture is negligible compared with the characteristic time of the macroscopic problem, e.g. change of boundary conditions. In that context, the lowest order approximation N = 1 has the form of solving a transient problem in a resistor/capacitor network, a so-called pipe network. Its topology is the same as the network of geometrical intersections between fractures. In this paper, we generalize this approach in order to account for fluxes from matrix to fractures. The quasi steady state hypothesis at the fracture level is still kept. Then, we show that in the case of well separated time scales between matrix and fractures, the preceding model needs only to be slightly modified in order to incorporate these fluxes. The additional knowledge of the so-called matrix to fracture transfer function allows to modify the mass matrix that becomes a time convolution operator. This is reminiscent of existing space averaged transient dual porosity models.

  10. High prevalence of radiological vertebral fractures in HIV-infected males.

    Science.gov (United States)

    Torti, Carlo; Mazziotti, Gherardo; Soldini, Pier Antonio; Focà, Emanuele; Maroldi, Roberto; Gotti, Daria; Carosi, Giampiero; Giustina, Andrea

    2012-06-01

    Age-related co-morbidities including osteoporosis are relevant in patients responding to combination antiretroviral therapy (cART). Vertebral fractures are common osteoporotic fractures and their diagnosis is useful for managing at-risk individuals. However, there are few data from HIV-infected patients. Therefore, the aim of this study was to determine the prevalence of and factors associated with vertebral fractures in a population of HIV-infected males. A cross-sectional study of 160 HIV-infected patients with available chest X-rays was conducted from 1998 to 2010. One hundred and sixty-three males with comparable age and with no history of HIV infection were recruited as controls. Semi-quantitative evaluation of vertebral heights in lateral chest X-rays and quantitative morphometry assessment of centrally digitized images using dedicated morphometry software were utilized to detect prevalent vertebral fractures. The result showed that the vertebral fractures were detected in 43/160 (26.9%) HIV-infected patients and in 21/163 (12.9%) controls (P = 0.002). In HIV-infected patients with fractures, 27 had two or more fractures and ten patients had severe fractures. The prevalence of any fractures and multiple fractures in HIV-infected patients receiving cART (29.6 and 20.0%) was slightly higher than in HIV-infected patients not exposed to cART (17.1 and 5.7%), but significantly higher than control subjects (12.9 and 3.7%). At multivariable analyses, body mass index and diabetes mellitus were independently correlated with vertebral fractures in HIV-infected patients. We concluded that a significant proportion of HIV-infected males receiving cART showed vertebral fractures. Furthermore, proactive diagnosis of vertebral fragility fractures is particularly relevant in patients who are overweight or suffer from diabetes.

  11. Bipolar disorder and the risk of fracture: A nationwide population-based cohort study.

    Science.gov (United States)

    Su, Jian-An; Cheng, Bi-Hua; Huang, Yin-Cheng; Lee, Chuan-Pin; Yang, Yao-Hsu; Lu, Mong-Liang; Hsu, Chung-Yao; Lee, Yena; McIntyre, Roger S; Chin Lin, Tzu; Chin-Hung Chen, Vincent

    2017-08-15

    The co-primary aims are: 1) to compare the risk of fracture between adults with bipolar disorder and those without bipolar disorder; and 2) to assess whether lithium, anticonvulsants and antipsychotics reduce risk of fracture among individuals with bipolar disorder. The analysis herein is a population-based retrospective cohort study, utilizing the National Health Insurance (NHI) medical claims data collected between 1997 and 2013 in Taiwan. We identified 3705 cases with incident diagnoses of bipolar disorder during study period and 37,050 matched controls without bipolar diagnoses. Incident diagnosis of fracture was operationalized as any bone fracture after the diagnosis of bipolar disorder or after the matched index date for controls. Bipolar patients had significantly higher risk of facture when compared to matched controls (17.6% versus 11.7%, respectively pbipolar disorder and a prior history of psychiatric hospitalization were had higher risk for bone fracture than those without prior history of psychiatric hospitalization when compared to match controls. Higher cumulative dose of antipsychotics or mood stabilizers did not increase the risk of fracture. The diagnoses of bipolar disorder were not confirmed with structured clinical interview. Drug adherence, exact exposure dosage, smoking, lifestyle, nutrition and exercise habits were unable to be assessed in our dataset. Bipolar disorder is associated with increased risk of fracture, and higher cumulative dose of mood stabilizers and antipsychotics did not further increase the risk of fracture. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Effect of yield stress matching on ductile fracture behavior of girth welds for X line pipe

    Energy Technology Data Exchange (ETDEWEB)

    Motohashi, Hiroyuki; Hagiwara, Naoto [Tokyo Gas Co., Ltd. (Japan)

    2005-07-01

    This paper describes the effects of yield stress matching on the ductile fracture behavior of girth welded joints for X linepipes. Three welded joints were made on an X line pipe using several consumables to obtain about a 20% overmatched, even matched and about a 20% under matched weld metal. For these three welded joints, curved wide plate tensile tests were then conducted with a surface notch in the weld metal. To determine the ductile crack initiation from the surface notch, these tests employed a direct-current electric potential (d-c E P) method. Crack opening displacement, gauge length strain and local strain adjacent to the surface notch were also measured. The ductile crack initiation was successfully detected using the d-c E P method. The yield stress matching significantly affected the ductile crack initiation and fracture behavior, that is, the overmatched welded joint had a higher resistance to ductile fracture than that of the under matched welded joint. The allowable strength matching level was determined from the relationship between the strength matching and the gauge length strain at the ductile crack initiation detected using the d-c E P method. (author)

  13. Prospecting fractured rock aquifers using radon soil gases method; Analise de radonio no solo para prospeccao de agua em aquiferos fraturados

    Energy Technology Data Exchange (ETDEWEB)

    Stefano, Paulo Henrique Prado; Roisenberg, Ari, E-mail: paulohenriquestefano@hotmail.com, E-mail: ari.roisenberg@ufrgs.br [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil); Gallas, Jose Domingos Faraco, E-mail: jgallas@usp.br [Universidade de Sao Paulo (USP), SP (Brazil); Rocha, Zildete, E-mail: zildete@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-11-01

    Groundwater prospecting in fractured aquifers depends on the detection of tectonic lineaments, which may be difficult in urban areas. A survey was carried out using radon soil gases concentrations in four localities in the region of Granite Santana and Viamao Granite, Porto Alegre, Rio Grande do Sul, in order to test the method for water prospecting in fractured aquifers. The radon data have been compared with electrical resistivity survey executed using dipole-dipole arrangement. At four studied areas, an interesting correlation was noted between the two methods. At regions of low resistivity, positive radon anomalies were found in fracture zones, reaching values up to 7 times the background of the region, starting from a concentration value of 2500 Bq/m{sup 3} in a non-fractured zones to 22187 Bq /m{sup 3} in the fractured zones. (author)

  14. Comparison of polytomography and computed tomography for fracture assessment

    International Nuclear Information System (INIS)

    Kuong, S.J.; Williamson, D.S.; Baker, N.D.; Sosman, J.L.; Nawfel, R.D.; Weissman, B.N.

    1999-01-01

    Objective. To compare polytomography (PT) and computed tomography (CT) for visualizing fractures and arthrodeses, with and without metal hardware, to determine whether CT could adequately replace PT.Design and patients. An ex vivo bovine model containing fractures in three planes, reduced with metal hardware, was created to compare fractures using PT and CT. The radiation dose at the skin surface was calculated for both examinations. For in vivo assessment, images of 14 patients who underwent both PT and CT (15 fractures, five arthrodeses) were coded, sorted, and independently read by four musculoskeletal radiologists. They rated the degree of certainty of their assessment. Time factors for patients and personnel and financial costs were also compared.Results. In the ex vivo model the fractures were well seen on both PT and CT. The radiation dose was higher for PT than for CT. In vivo, the degree of certainty in assessment of fractures and arthrodeses was higher for PT than CT in studies in which metal hardware was present, but there was no significant difference in studies without metal hardware or in the combined (with and without hardware) studies. The patient's and technologist's time required to perform a PT examination was greater than that for CT.Conclusion. In the assessment of fractures and arthrodeses containing metal hardware, PT is recommended. For studies without hardware, CT is equivalent and can replace PT. (orig.)

  15. Hydraulic Parameter Generation Technique Using a Discrete Fracture Network with Bedrock Heterogeneity in Korea

    Directory of Open Access Journals (Sweden)

    Jae-Yeol Cheong

    2017-12-01

    Full Text Available In instances of damage to engineered barriers containing nuclear waste material, surrounding bedrock is a natural barrier that retards radionuclide movement by way of adsorption and delay due to groundwater flow through highly tortuous fractured rock pathways. At the Gyeongju nuclear waste disposal site, groundwater mainly flows through granitic and sedimentary rock fractures. Therefore, to understand the nuclide migration path, it is necessary to understand discrete fracture networks based on heterogeneous fracture orientations, densities, and size characteristics. In this study, detailed heterogeneous fracture distribution, including the density and orientation of the fractures, was considered for a region that has undergone long periods of change from various geological activities at and around the Gyeongju site. A site-scale discrete fracture network (DFN model was constructed taking into account: (i regional fracture heterogeneity constrained by a multiple linear regression analysis of fracture intensity on faults and electrical resistivity; and (ii the connectivity of conductive fractures having fracture hydraulic parameters, using transient flow simulation. Geometric and hydraulic heterogeneity of the DFN was upscaled into equivalent porous media for flow and transport simulation for a large-scale model.

  16. Effect of Glide Path Creating on Cyclic Fatigue Resistance of Reciproc and Reciproc Blue Nickel-titanium Files: A Laboratory Study.

    Science.gov (United States)

    Özyürek, Taha; Uslu, Gülşah; Yılmaz, Koray; Gündoğar, Mustafa

    2018-06-01

    The purpose of this article was to compare the cyclic fatigue resistance of Reciproc and Reciproc Blue files (VDW GmbH, Munich, Germany) that were used to prepare root canals of mandibular molar teeth with or without a glide path. Sixty Reciproc R25 and 60 Reciproc Blue R25 files were used. The Reciproc and Reciproc Blue groups were divided into 3 subgroups (ie, as received condition, used without a glide path, and used with a glide path). All the instruments were rotated in a stainless steel artificial canal with an inner diameter of 1.5 mm, a 60° angle of curvature, and a radius of curvature of 5 mm until fracture occurred. The number of cycle to fracture was calculated, and the length of the fractured segments was measured. The Kruskal-Wallis test was performed to statistically analyze the data using SPSS 21.0 software (IBM Corp, Armonk, NY) at a 5% significance level. The cyclic fatigue resistance of as received condition Reciproc Blue files was found to be higher than as received condition Reciproc files (P  .05). There was no statistically significant difference in the mean length of the fractured fragments of the instruments (P > .05). Within the limitations of this in vitro study, it was concluded that creating a glide path using ProGlider files had no effect on the cyclic fatigue resistance of RPC and RPC Blue files. Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  17. Laboratory investigations into fracture propagation characteristics of rock material

    Science.gov (United States)

    Prasad, B. N. V. Siva; Murthy, V. M. S. R.

    2018-04-01

    After Industrial Revolution, demand of materials for building up structures have increased enormously. Unfortunately, failures of such structures resulted in loss of life and property. Rock is anisotropic and discontinuous in nature with inherent flaws or so-called discontinuities in it. Rock is apparently used for construction in mining, civil, tunnelling, hydropower, geothermal and nuclear sectors [1]. Therefore, the strength of the structure built up considering rockmass as the construction material needs proper technical evaluation during designing stage itself to prevent and predict the scenarios of catastrophic failures due to these inherent fractures [2]. In this study, samples collected from nine different drilling sites have been investigated in laboratory for understanding the fracture propagation characteristics in rock. Rock material properties, ultrasonic velocities through pulse transmission technique and Mode I Fracture Toughness Testing of different variants of Dolomites and Graywackes are determined in laboratory and the resistance of the rock material to catastrophic crack extension or propagation has been determined. Based on the Fracture Toughness values and the rock properties, critical Energy Release Rates have been estimated. However further studies in this direction is to be carried out to understand the fracture propagation characteristics in three-dimensional space.

  18. Analysis of the resistance to the stable propagation of fissures in structural steels

    International Nuclear Information System (INIS)

    Alvarez Villar, Nelson; Aquino, Daniel; Aguera, Francisco; Fierro, Victor; Ansaldi, Andrea; Chomik, Enrique; Iorio, Antonio

    2008-01-01

    Linear Elastic Fracture Mechanic (LEFM) is applied to the analysis of highly resistant materials, with correction for plasticity. For moderately ductile materials, structural analysis and design methodologies based on Elastoplastic Fracture Mechanics (EPFM) still have to be developed. The J integral is used in EPFM as a parameter to characterize tenacity to the fracture, following the ASTM standard. It is important to obtain J-Resistant curves, since the use of the stable propagation initiation value (J IC ) as failure criteria, leads to results that are too conservative in most design situations. The application of direct methods allows for results under conditions where the standard methods for obtaining the J-Resistant curve are not applicable. This work analyzes the application of direct methods that are alternatives for the standard, in ferritic-perlitic steels used in gas transport pipes. Experimental results are presented with numerical analysis (FEA) for the adjustment of J-Resistant curves (au)

  19. The fracture properties and toughening mechanisms of bone and dentin

    Science.gov (United States)

    Koester, Kurt John

    The mechanical properties of bone and dentin and in particular their fracture properties, are the subject of intense research. The relevance of these properties is increasing as our population ages and fracture incidence impacts the lives of a greater portion of the population. A robust framework is needed to understand the fracture properties of bone and dentin to guide researchers as they attempt to characterize the effects of aging, disease, and pharmaceutical treatments on the properties of these mineralized tissues. In the present work, this framework is provided and applied to human bone, human dentin, and animal bone. In situ electron microscopy was also used to identify the salient toughening mechanisms in bone and dentin. It was found that bone and dentin are extrinsically toughened materials and consequently their fracture properties are best characterized utilizing a crack-growth resistance approach. A description of the different mechanical measurements commonly employed when using small animal models (rats and mice) to evaluate the influence of drug therapies on bone fragility is provided. A study where these properties were measured for a large population of wild-type rats and mice was also conducted. Given my findings, it was determined that for the most complete understanding of small animal bone it was necessary to measure strength and toughness. Strength measurements probe the flaw distribution and toughness measurements to evaluate the resistance to facture in the presence of a single dominant worst-case flaw.

  20. Resistance to fracture of carbon weldable structural steel with ferrite-pearlite and widmanstaetten structure

    International Nuclear Information System (INIS)

    Gulyaev, A.P.; Guzovskaya, M.A.

    1977-01-01

    Consideration is given to mechanical properties of St3 steel with varying ferritic-peartilic and widmanstaetten structures typical of a weld seam and adjacent zones. It has been found that mechanical properties determined at static tension are sensitive to structure variation in the limits under study. A considerable difference has been detected during impact tests CT 50 , asub(p)). The highest resistance to breakage is observed for the steel with a fine-grain ferritic-pearlitic structure (T 50 =-10 deg C, asub(p)=4.3 kgxm/cm 2 ). The enlargement of such a structure enhances transition temperature (T 50 =+20 deg C) and reduces resistance to crack development (asub(p)2.4 kgxm/cm 2 ). The appearance of widmanstaetten zones in the fine-grain structure leads also to a higher T 50 , up to +10 deg C, and at a completely widmanstaetten structure T 50 =+25 deg C. An especially unfavorable effect on the resistance of steel to breakage is produced by structure nonuniformity, i.e. accumulation of loop-like pearlitic and ferritic zones

  1. Bimalleolar ankle fracture with proximal fibular fracture

    NARCIS (Netherlands)

    Colenbrander, R. J.; Struijs, P. A. A.; Ultee, J. M.

    2005-01-01

    A 56-year-old female patient suffered a bimalleolar ankle fracture with an additional proximal fibular fracture. This is an unusual fracture type, seldom reported in literature. It was operatively treated by open reduction and internal fixation of the lateral malleolar fracture. The proximal fibular

  2. Standard test method for determination of resistance to stable crack extension under low-constraint conditions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This standard covers the determination of the resistance to stable crack extension in metallic materials in terms of the critical crack-tip-opening angle (CTOAc), ψc and/or the crack-opening displacement (COD), δ5 resistance curve (1). This method applies specifically to fatigue pre-cracked specimens that exhibit low constraint (crack-length-to-thickness and un-cracked ligament-to-thickness ratios greater than or equal to 4) and that are tested under slowly increasing remote applied displacement. The recommended specimens are the compact-tension, C(T), and middle-crack-tension, M(T), specimens. The fracture resistance determined in accordance with this standard is measured as ψc (critical CTOA value) and/or δ5 (critical COD resistance curve) as a function of crack extension. Both fracture resistance parameters are characterized using either a single-specimen or multiple-specimen procedures. These fracture quantities are determined under the opening mode (Mode I) of loading. Influences of environment a...

  3. Fracture strengths of chair‑side‑generated veneers cemented with ...

    African Journals Online (AJOL)

    2014-06-09

    Jun 9, 2014 ... Group 1), CAD/CAM‑fabricated veneers cemented with a glass fiber ... specimens were tested with a universal testing machine after thermal cycling treatment. ... The purpose of the current in vitro study is to determine the ..... fracture resistance of fiber reinforced cups‑replacing composite restorations.

  4. On effect of some thermodeformation parameters of welding cycle on tendency of pearlitic heat-resisting steels to fracture in reheating

    International Nuclear Information System (INIS)

    Prokhorov, N.N.; Bardokin, E.V.

    1979-01-01

    Studied is the inclination of the 12Kh1MF, 15Kh3M1F and N18K9M5T steels subject to thermodeformation cycle imitating a welding one, to fracture in reheating. A hot-rolled metal then subject to the same thermal treatment was used. The imitation of thermodeformation cycle of the welding permitted to vary maximum heating temperatures, the period during which the metal is kept at temperatures higher than 1100 deg C, and the cooling rate of ajacent zone metal. It is shown that the curve of the dependence of deformation ability and the tendency to fracture at the reheating of adjacent zone metal on the rate of its cooling at welding is U-shaped. Deformation ability has its maximum value at the cooling rate of 30 deg c/s in the range 1300 to 1000 deg C

  5. Treatment of Pediatric Condylar Fractures: A 20-Year Experience.

    Science.gov (United States)

    Ghasemzadeh, Ali; Mundinger, Gerhard S; Swanson, Edward W; Utria, Alan F; Dorafshar, Amir H

    2015-12-01

    The purpose of this study was to define patterns of injury and treatment for condylar and subcondylar fractures and evaluate short-term outcomes in the pediatric population. A retrospective chart review was performed on pediatric patients with mandibular condylar fractures who presented between 1990 and 2010. Computed tomographic imaging was reviewed for all patients to assess fracture characteristics. Mandibular fractures were codified using the Strasbourg Osteosynthesis Research Group and Lindahl classification methods. Sixty-four patients with 92 condylar fractures were identified. Of these patients, 29 had isolated condylar fracture and 35 had a condylar fracture associated with an additional mandibular arch fracture. The most common fracture patterns were diacapitular fracture in the Strasbourg Osteosynthesis Research Group system (n = 46) and vertical condylar head fracture in the Lindahl system (n = 14). Condylar fracture with additional mandibular arch fractures were treated with maxillomandibular fixation more often than patients with condylar fracture [n = 40 (74.1 percent) versus n = 14 (25.9 percent); p = 0.004]. No condylar fracture was treated in an open fashion. Forty-three patients returned for follow-up. The median follow-up period was 81 days (interquartile range, 35 to 294 days). Ten patients had complications (23.3 percent). The most common complication was malocclusion (n = 5). Nine of 10 patients with complications had condylar fracture with an additional mandibular arch fracture. Closed treatment of condylar fractures yields satisfactory results in pediatric patients. Pediatric patients with condylar fractures combined with additional arch fractures experience a higher rate of unfavorable outcomes.

  6. on GAGD EOR in Naturally Fractured Reservoirs

    Directory of Open Access Journals (Sweden)

    Misagh Delalat

    2013-01-01

    Full Text Available The gas-assisted gravity drainage (GAGD process is designed and practiced based on gravity drainage idea and uses the advantage of density difference between injected CO2 and reservoir oil. In this work, one of Iran western oilfields was selected as a case study and a sector model was simulated based on its rock and fluid properties. The pressure of CO2 gas injection was close to the MMP of the oil, which was measured 1740 psia. Both homogeneous and heterogeneous types of fractures were simulated by creating maps of permeability and porosity. The results showed that homogeneous fractures had the highest value of efficiency, namely 40%; however, in heterogeneous fractures, the efficiency depended on the value of fracture density and the maximum efficiency was around 37%. Also, the effect of injection rate on two different intensities of fracture was studied and the results demonstrated that the model having higher fracture intensity had less limitation in increasing the CO2 injection rate; furthermore, its BHP did not increase intensively at higher injection rates either. In addition, three different types of water influxes were inspected on GAGD performance to simulate active, partial, and weak aquifer. The results showed that strong aquifer had a reverse effect on the influence of GAGD and almost completely disabled the gravity drainage mechanism. Finally, we inventively used a method to weaken the aquifer strength, and thus the gravity drainage revived and efficiency started to increase as if there was no aquifer.

  7. An investigation on the crack growth resistance of human tooth enamel: Anisotropy, microstructure and toughening

    Science.gov (United States)

    Yahyazadehfar, Mobin

    due to the higher organic content. Through these findings the present investigation provides new understanding on the fracture resistance of enamel, which is essential to advancements in the field of restorative dentistry, as well as in the design of new restorative and bio-inspired materials.

  8. Seismic and resistivity anisotropy analysis at the Low-Noise Underground Laboratory (LSBB) of Rustrel (France)

    Science.gov (United States)

    Zeyen, H. J.; Bereš, J.; Gaffet, S.; Sénéchal, G.; Rousset, D.; Pessel, M.

    2011-12-01

    Many geological materials exhibit anisotropic behaviour. A limestone massif, especially if cracked with fractures and faults in a predominant orientation is expected to manifest seismic and electric resistivity anisotropy. Seismic velocity within air- or water-filled cracks is smaller than in the rock matrix. Therefore, the velocity parallel to fractures, controlled mainly by the rock matrix, is expected to be faster than perpendicular to the fractures, where waves have to cross fractures and rock matrix. Seismic and resistivity measurements were conducted in three underground galleries of the Low-Noise Underground Gallery (LSBB) in southern France forming a horse-shoe setting. The galleries are located inside a karstic limestone massif. Around 22500 first arrival travel-times were picked and different types of pole-pole and dipole-dipole resistivity measurement were carried out in parallel. Resistivities and velocities vary strongly with direction of observation. The direction of fast velocities is at right angle with the one of slow velocities, a typical sign for anisotropy. Observation of a system of subparallel fractures allows to approximate the actual rock anisotropy by a horizontal transverse isotropy model. The dataset was treated by different approaches, including simple cosine fit, inversion of average anisotropy parameters using a Monte-Carlo approach, isotropic and anisotropic tomography inversion. All of the above confirm the directions of fast and slow velocities (30°N and 120°N respectively) and an anisotropy of about 10%. Common measurements of seismic and resistivity data at different periods of the year will have the potential to determine quantitatively the fracture density and the free water content in this karst massif.

  9. Surgical Management of a Mandible Subcondylar Fracture

    Directory of Open Access Journals (Sweden)

    Dong Hee Kang

    2012-07-01

    Full Text Available Open reduction and anatomic reduction can create better function for the temporomandibularjoint, compared with closed treatment in mandible fracture surgery. Therefore, the doubleminiplate fixation technique via mini-retromandibular incision was used in order to makethe most stable fixation when performing subcondylar fracture surgery. Those approachesprovide good visualization of the subcondyle from the posterior edge of the ramus, allow thesurgeon to work perpendicularly to the fracture, and enable direct fracture management.Understanding the biomechanical load in the fixation of subcondylar fractures is alsonecessary in order to optimize fixation methods. Therefore, we measured the biomechanicalloads of four different plate fixation techniques in the experimental model regardingmandibular subcondylar fractures. It was found that the loads measured in the two-platefixation group with one dynamic compression plate (DCP and one adaption plate showed thehighest deformation and failure loads among the four fixation groups. The loads measuredin the one DCP plate fixation group showed higher deformation and failure loads than theloads measured in the two adaption plate fixation group. Therefore, we conclude that theselection of the high profile plate (DCP is also important in order to create a stable load in thesubcondylar fracture.

  10. Effects of salmon calcitonin on fracture healing in ovariectomized rats.

    Science.gov (United States)

    Li, Xiaolin; Luo, Xinle; Yu, Nansheng; Zeng, Bingfang

    2007-01-01

    To explore the effects of salmon calcitonin on the healing process of osteoporotic fractures in ovariectomized rats. We performed this study in The First Affiliated Hospital of Guangzhou Medical College, Guangzhou, China, during the period March 2002 to December 2004. We used 120 female adult Wistar rats in this experiment, among which 90 underwent ovariectomy (OVX) and the other 30 had sham-operation. All rats had their left tibias fractured 3 months later. The 90 OVX rats were randomly divided into 3 groups with 30 in each, while the 30 sham-operated rats served as control group. After the fracture the rats had subcutaneous injection of normal saline, salmon calcitonin and estrogen, respectively. X-ray film, histological examination, bone mineral density (BMD) measurement and biomechanics testing were carried out to evaluate the fracture healing. Compared with OVX rats treated with normal saline, the rats with salmon calcitonin had significantly higher BMD values in the left tibia, higher max torque, shear stress of the left tibia 8 weeks after fracture (pnormalization of microstructure of bone trabeculae. Salmon calcitonin can, not only increase BMD in osteoporotic bone, but also enhance the bone biomechanical properties and improve the process of fracture healing in fractured osteoporotic bone.

  11. Effects of salmon calcitonin on fracture healing in ovariectomized rats

    International Nuclear Information System (INIS)

    Li, Xiaolin; Zeng, Bingfang; Luo, Xinle; Yu, Nansheng

    2007-01-01

    Objective was to explore the effects of salmon calcitonin on the healing process of osteoporotic fractures in ovariectomized rats. We performed this study in the First Affiliated Hospital of Guangzhaou Medical College, Guangzhaou, China during the period March 2002 to December 2004. We used 120 female adult Wistar rats in this experiment, among which 90 underwent ovariectomy (OVX) and the other 30 had shamoperation. All rats had their left tibias fractured 3 months later. The 90 OVX rats were randomly divided into 3 groups with 30 in each, while the 30 shamoperated rats served as control group. After the fracture rats had subcutaneous injection of normal saline, salmon calcitonin and estrogen, respectively. X-ray film, histological examination, bone mineral density (BMD) measurement and biomechanics testing were carried out to evaluate the fracture healing. Compared with OVX rats treated normal saline, the rats with salmon calcitonin had significantly higher BMD values in the left tibia, higher max torque, shear stress of the left tibia 8 weeks after fracture (p<0.05), and presented with stronger callus formation, shorter fracture healing time and faster normalization of microstructure of bone trabeculae. Salmon calcitonin can, not only increase in osteoporotic bone biomechanical properties and improve the process of fractured osteoporotic bone. (author)

  12. Elastic-plastic fracture assessment using a J-R curve by direct method

    International Nuclear Information System (INIS)

    Asta, E.P.

    1996-01-01

    In the elastic-plastic evaluation methods, based on J integral and tearing modulus procedures, an essential input is the material fracture resistance (J-R) curve. In order to simplify J-R determination direct, a method from load-load point displacement records of the single specimen tests may be employed. This procedure has advantages such as avoiding accuracy problems of the crack growth measuring devices and reducing testing time. This paper presents a structural integrity assessment approach, for ductile fracture, using the J-R obtained by a direct method from small single specimen fracture tests. The J-R direct method was carried out by means of a developed computational program based on theoretical elastic-plastic expressions. A comparative evaluation between the direct method J resistance curves and those obtained by the standard testing methodology on typical pressure vessel steels has been made. The J-R curves estimated from the direct method give an acceptable agreement with the approach proposed in this study which is reliable to use for engineering determinations. (orig.)

  13. Direct and indirect costs of surgically treated pelvic fractures.

    Science.gov (United States)

    Aprato, Alessandro; Joeris, Alexander; Tosto, Ferdinando; Kalampoki, Vasiliki; Stucchi, Alessandro; Massè, Alessandro

    2016-03-01

    Pelvic fractures requiring surgical fixation are rare injuries but present a great societal impact in terms of disability, as well as economic resources. In the literature, there is no description of these costs. Main aim of this study is to describe the direct and indirect costs of these fractures. Secondary aims were to test if the type of fracture (pelvic ring injury or acetabular fracture) influences these costs (hospitalization, consultation, medication, physiotherapy sessions, job absenteeism). We performed a retrospective study on patients with surgically treated acetabular fractures or pelvic ring injuries. Medical records were reviewed in terms of demographic data, follow-up, diagnosis (according to Letournel and Tile classifications for acetabular and pelvic fractures, respectively) and type of surgical treatment. Patients were interviewed about hospitalization length, consultations after discharge, medications, physiotherapy sessions and absenteeism. The study comprised 203 patients, with a mean age of 49.1 ± 15.6 years, who had undergone surgery for an acetabular fracture or pelvic ring injury. The median treatment costs were 29.425 Euros per patient. Sixty percent of the total costs were attributed to health-related work absence. Median costs (in Euros) were 2.767 for hospitalization from trauma to definitive surgery, 4.530 for surgery, 3.018 for hospitalization in the surgical unit, 1.693 for hospitalization in the rehabilitation unit, 1.920 for physiotherapy after discharge and 402 for consultations after discharge. Total costs for treating pelvic ring injuries were higher than for acetabular fractures, mainly due to the significant higher costs of pelvic injuries regarding hospitalization from trauma to definitive surgery (p fractures are associated with both high direct costs and substantial productivity loss.

  14. Insufficiency fracture of the pelvis after the radiotherapy for carcinoma of the uterine cervix

    International Nuclear Information System (INIS)

    Nishimura, Tetsuo; Shimizu, Teppei; Sugiyama, Akira; Ichinohe, Kenji; Teshima, Takeshi; Takahashi, Motoichiro; Takai, Michikatsu; Kaneko, Masao

    1990-01-01

    Bone injury after radiotherapy for carcinoma of the uterine cervix has been reported since early days of this century. Recently, the concept of insufficiency fracture has been confirmed. Insufficiency fracture is one of the stress fractures and occurs when the elastic resistance of bone is inadequate to withstand normal or physiological stress. In the American and European studies, radiotherapy is known as a cause of insufficiency fracture. There are no reports on insufficiency fracture in the Japanese literatures. Four cases of carcinomas of the uterine cervix presented pelvic insufficiency fractures following radiotherapy. In the pubic bone, a vertical parasymphyseal fracture with mixed lytic and sclerotic changes of surrounding tissue is characteristic. Sacral insufficiency fracture shows a vertical or horizontal line with lytic and sclerotic appearance. Bone scintigraphy is a sensitive modality for the early detection. H-shaped configuration is diagnostic for sacral insufficiency fracture. CT is an accurate technique demonstrating a vertical fracture and excluding the malignant bony lesion. Although radiological findings of insufficiency fracture are similar to bone malignancy, differential diagnosis from malignant lesions is possible. Bony symptoms of all patients disappeared without specific treatments. In the follow-up study of patients with carcinomas of the uterine cervix after radiotherapy, it is important to have the consideration on insufficiency fracture. (author)

  15. Clinical effects of internal fixation for ulnar styloid fractures associated with distal radius fractures: A matched case-control study.

    Science.gov (United States)

    Sawada, Hideyoshi; Shinohara, Takaaki; Natsume, Tadahiro; Hirata, Hitoshi

    2016-11-01

    Ulnar styloid fractures are often associated with distal radius fractures. However, controversy exists regarding whether to treat ulnar styloid fractures. This study aimed to evaluate clinical effects of internal fixation for ulnar styloid fractures after distal radius fractures were treated with the volar locking plate system. We used prospectively collected data of distal radius fractures. 111 patients were enrolled in this study. A matched case-control study design was used. We selected patients who underwent fixation for ulnar styloid fractures (case group). Three control patients for each patient of the case group were matched on the basis of age, sex, and fracture type of distal radius fractures from among patients who did not undergo fixation for ulnar styloid fractures (control group). The case group included 16 patients (7 men, 9 women; mean age: 52.6 years; classification of ulnar styloid fractures: center, 3; base, 11; and proximal, 2). The control group included 48 patients (15 men, 33 women; mean age: 61.1 years; classification of ulnar styloid fractures: center, 10; base, 31; and proximal, 7). For radiographic examination, the volar tilt angle, radial inclination angle, and ulnar variance length were measured, and the union of ulnar styloid fractures was judged. For clinical examination, the range of motions, grip strength, Hand20 score, and Numeric Rating Scale score were evaluated. There was little correction loss for each radiological parameter of fracture reduction, and these parameters were not significantly different between the groups. The bone-healing rate of ulnar styloid fractures was significantly higher in the case group than in the control group, but the clinical results were not significantly different. We revealed that there was no need to fix ulnar styloid fractures when distal radius fractures were treated via open reduction and internal fixation with a volar locking plate system. Copyright © 2016 The Japanese Orthopaedic Association

  16. Foal Fractures: Osteochondral Fragmentation, Proximal Sesamoid Bone Fractures/Sesamoiditis, and Distal Phalanx Fractures.

    Science.gov (United States)

    Reesink, Heidi L

    2017-08-01

    Foals are susceptible to many of the same types of fractures as adult horses, often secondary to external sources of trauma. In addition, some types of fractures are specific to foals and occur routinely in horses under 1 year of age. These foal-specific fractures may be due to the unique musculoskeletal properties of the developing animal and may present with distinct clinical signs. Treatment plans and prognoses are tailored specifically to young animals. Common fractures not affecting the long bones in foals are discussed in this article, including osteochondral fragmentation, proximal sesamoid bone fractures/sesamoiditis, and distal phalanx fractures. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Pairwise and higher-order correlations among drug-resistance mutations in HIV-1 subtype B protease

    Directory of Open Access Journals (Sweden)

    Morozov Alexandre V

    2009-08-01

    Full Text Available Abstract Background The reaction of HIV protease to inhibitor therapy is characterized by the emergence of complex mutational patterns which confer drug resistance. The response of HIV protease to drugs often involves both primary mutations that directly inhibit the action of the drug, and a host of accessory resistance mutations that may occur far from the active site but may contribute to restoring the fitness or stability of the enzyme. Here we develop a probabilistic approach based on connected information that allows us to study residue, pair level and higher-order correlations within the same framework. Results We apply our methodology to a database of approximately 13,000 sequences which have been annotated by the treatment history of the patients from which the samples were obtained. We show that including pair interactions is essential for agreement with the mutational data, since neglect of these interactions results in order-of-magnitude errors in the probabilities of the simultaneous occurence of many mutations. The magnitude of these pair correlations changes dramatically between sequences obtained from patients that were or were not exposed to drugs. Higher-order effects make a contribution of as much as 10% for residues taken three at a time, but increase to more than twice that for 10 to 15-residue groups. The sequence data is insufficient to determine the higher-order effects for larger groups. We find that higher-order interactions have a significant effect on the predicted frequencies of sequences with large numbers of mutations. While relatively rare, such sequences are more prevalent after multi-drug therapy. The relative importance of these higher-order interactions increases with the number of drugs the patient had been exposed to. Conclusion Correlations are critical for the understanding of mutation patterns in HIV protease. Pair interactions have substantial qualitative effects, while higher-order interactions are

  18. Effect of sized and specimen geometry on the initiation and propagation of the ductile fracture

    International Nuclear Information System (INIS)

    Frund, J.M.; Marini, B.; Bethmont, M.

    1994-02-01

    Strength to the fracture of the pipe in PWR has to be justified with mechanical analyses. These tests are based on the strength to ductile fracture of steels which are tested in lab. The values of resistance to fracture are obtained through tensile tests on CT specimens (determination of J-R curves). The purpose of this study is to justify the sizes of the specimens which have to be used to characterize the strength to ductile fracture of steel in secondary pipes. Tests were conducted on 0,5T-CT, 1T-CT and 2T-CT specimens. Two materials with different suffer contents were studied. The test results show that the JO,2 values gotten from the different specimens are similar. But the strength to ductile fracture in 2T-CT specimens in lower than the one measured in 0,5t-CT and 1T-CT specimens. The surface of fracture of the different specimens displays splits perpendicular to the notch and parallel to the sheet surface. These splits are produced by the separation of the manganese sulfur inclusions. The effect notes on the J-R curves seems to be relevant to these splits. The reason why these splits might be responsible for a decrease of the tearing modulus are not clearly defined up to this point. The results which have been published show the importance of the geometry effects (presence or not of lateral notches...) and the loading mode on the strength to ductile fracture. We note that the curves determined from tests on CT specimens are conservative. A few preliminary studies showed that the geometry effects on resistance to fracture can be studied and explained by using local approach methods. The Rousselier modeling is useful to explain the behaviour of ferritic steels in ductile fracture. (authors). 20 refs., 7 figs., 5 tabs

  19. Tissue-Level Mechanical Properties of Bone Contributing to Fracture Risk.

    Science.gov (United States)

    Nyman, Jeffry S; Granke, Mathilde; Singleton, Robert C; Pharr, George M

    2016-08-01

    Tissue-level mechanical properties characterize mechanical behavior independently of microscopic porosity. Specifically, quasi-static nanoindentation provides measurements of modulus (stiffness) and hardness (resistance to yielding) of tissue at the length scale of the lamella, while dynamic nanoindentation assesses time-dependent behavior in the form of storage modulus (stiffness), loss modulus (dampening), and loss factor (ratio of the two). While these properties are useful in establishing how a gene, signaling pathway, or disease of interest affects bone tissue, they generally do not vary with aging after skeletal maturation or with osteoporosis. Heterogeneity in tissue-level mechanical properties or in compositional properties may contribute to fracture risk, but a consensus on whether the contribution is negative or positive has not emerged. In vivo indentation of bone tissue is now possible, and the mechanical resistance to microindentation has the potential for improving fracture risk assessment, though determinants are currently unknown.

  20. Residual impairment after lower extremity fracture

    DEFF Research Database (Denmark)

    Faergemann, C; Frandsen, P A; Röck, N D

    1998-01-01

    In a prospective follow-up study of 158 consecutive patients 18 to 64 years old with unilateral lower extremity fracture, our aim was to disclose the impairment and disability 6 months after the injury. The patients were interviewed within 1 week after the trauma, and all patients returned...... the functional status before the injury. Additionally, three major aspects of impairments were measured 6 months after the fractures: range of motion, muscle strength, and pain. Most patients had a significantly higher SIP score 6 months after the fracture(s) than pretraumatically. The mean overall SIP score...... was 2.7 pretraumatically and 8.7 6 months posttraumatically. Major deficits in range of motion was observed, especially in the ankle joint. Additionally, loss of muscle strength was observed in the thigh and calf muscles in one fourth of the patients. Only low levels of residual pain were reported after...

  1. The effect of irradiation and irradiation temperature on the fracture toughness of cold-worked Zr-2.5 wt percent Nb

    International Nuclear Information System (INIS)

    Simpson, L.A.; Ellis, R.B.; Stark, D.J.; Shillinglaw, A.J.

    1984-09-01

    The use of fracture mechanics methods and small specimens to assess the effect of metallurgical variables on fracture toughness and critical crack length in reactor pressure tubes is reviewed. Fracture toughness tests on specimens irradiated in the NRU research reactor at 260 degrees C are described and compared with results from a previous irradiation in the WR-1 research reactor at 350 degrees C. The J-resistance curve is used as the measure of fracture toughness, and is shown to be very sensitive to the metallurgical state. The lower irradiation temperature (260 degrees C), characteristic of the operating temperature range for power reactors, has a significant effect on fracture toughness. Circumferential hydrides also have an effect. Estimates of critical crack length are made using the J-resistance data, and are seen to slightly underestimate the actual critical crack length as determined in full-scale burst tests. This conservatism is not large enough to impose a significant penalty in design applications

  2. Discrete Dual Porosity Modeling of Electrical Current Flow in Fractured Media

    Science.gov (United States)

    Roubinet, D.; Irving, J.

    2013-12-01

    The study of fractured rocks is highly important in a variety of research fields and applications such as hydrogeology, geothermal energy, hydrocarbon extraction, and the long-term storage of toxic waste. Fractured media are characterized by a large contrast in permeability between the fractures and the rock matrix. For hydrocarbon extraction, the presence of highly conductive fractures is an advantage as they allow for quick and easy access to the resource. For toxic waste storage, however, the fractures represent a significant drawback as there is an increased risk of leakage and migration of pollutants deep into the subsurface. In both cases, the identification of fracture network characteristics is a critical, challenging, and required step. A number of previous studies have indicated that the presence of fractures in geological materials can have a significant impact on geophysical electrical resistivity measurements. It thus appears that, in some cases, geoelectrical surveys might be used to obtain useful information regarding fracture network characteristics. However, existing geoelectrical modeling tools and inversion methods are not properly adapted to deal with the specific challenges of fractured media. This prevents us from fully exploring the potential of the method to characterize fracture network properties. We thus require, as a first step, the development of accurate and efficient numerical modeling tools specifically designed for fractured domains. Building on the discrete fracture network (DFN) approach that has been widely used for modeling groundwater flow in fractured rocks, we have developed a discrete dual-porosity model for electrical current flow in fractured media. Our novel approach combines an explicit representation of the fractures with fracture-matrix electrical flow exchange at the block-scale. Tests in two dimensions show the ability of our method to deal with highly heterogeneous fracture networks in a highly computationally

  3. Education, marital status, and risk of hip fractures in older men and women: the CHANCES project.

    Science.gov (United States)

    Benetou, V; Orfanos, P; Feskanich, D; Michaëlsson, K; Pettersson-Kymmer, U; Ahmed, L A; Peasey, A; Wolk, A; Brenner, H; Bobak, M; Wilsgaard, T; Schöttker, B; Saum, K-U; Bellavia, A; Grodstein, F; Klinaki, E; Valanou, E; Papatesta, E-M; Boffetta, P; Trichopoulou, A

    2015-06-01

    The role of socioeconomic status in hip fracture incidence is unclear. In a diverse population of elderly, higher education was found to be associated with lower, whereas living alone, compared to being married/cohabiting, with higher hip fracture risk. Educational level and marital status may contribute to hip fracture risk. The evidence on the association between socioeconomic status and hip fracture incidence is limited and inconsistent. We investigated the potential association of education and marital status with hip fracture incidence in older individuals from Europe and USA. A total of 155,940 participants (79 % women) aged 60 years and older from seven cohorts were followed up accumulating 6456 incident hip fractures. Information on education and marital status was harmonized across cohorts. Hip fractures were ascertained through telephone interviews/questionnaires or through record linkage with registries. Associations were assessed through Cox proportional hazard regression adjusting for several factors. Summary estimates were derived using random effects models. Individuals with higher education, compared to those with low education, had lower hip fracture risk [hazard ratio (HR) = 0.84, 95 % confidence interval (CI) 0.72-0.95]. Respective HRs were 0.97 (95 % CI 0.82-1.13) for men and 0.75 (95 % CI 0.65-0.85) for women. Overall, individuals living alone, especially those aged 60-69 years, compared to those being married/cohabiting, tended to have a higher hip fracture risk (HR = 1.12, 95 % CI 1.02-1.22). There was no suggestion for heterogeneity across cohorts (P heterogeneity > 0.05). The combined data from >150,000 individuals 60 years and older suggest that higher education may contribute to lower hip fracture risk. Furthermore, this risk may be higher among individuals living alone, especially among the age group 60-69 years, when compared to those being married/cohabiting.

  4. Analytical, numerical and experimental investigations of transverse fracture propagation from horizontal wells

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, M.M.; Hossain, M.M.; Crosby, D.G.; Rahman, M.K.; Rahman, S.S. [School of Petroleum Engineering, The University of New South Wales, 2052 Sydney (Australia)

    2002-08-01

    This paper presents results of a comprehensive study involving analytical, numerical and experimental investigations into transverse fracture propagation from horizontal wells. The propagation of transverse hydraulic fractures from horizontal wells is simulated and investigated in the laboratory using carefully designed experimental setups. Closed-form analytical theories for Mode I (opening) stress intensity factors for idealized fracture geometries are reviewed, and a boundary element-based model is used herein to investigate non-planar propagation of fractures. Using the mixed mode fracture propagation criterion of the model, a reasonable agreement is found with respect to fracture geometry, net fracture pressures and fracture propagation paths between the modeled fractures and the laboratory tested fractures. These results suggest that the propagation of multiple fractures requires higher net pressures than a single fracture, the underlying reason of which is theoretically justified on the basis of local stress distribution.

  5. The role of organic proteins on the crack growth resistance of human enamel.

    Science.gov (United States)

    Yahyazadehfar, Mobin; Arola, Dwayne

    2015-06-01

    With only 1% protein by weight, tooth enamel is the most highly mineralized tissue in mammals. The focus of this study was to evaluate contributions of the proteins on the fracture resistance of this unique structural material. Sections of enamel were obtained from the cusps of human molars and the crack growth resistance was quantified using a conventional fracture mechanics approach with complementary finite element analysis. In selected specimens the proteins were extracted using a potassium hydroxide treatment. Removal of the proteins resulted in approximately 40% decrease in the fracture toughness with respect to the fully proteinized control. The loss of organic content was most detrimental to the extrinsic toughening mechanisms, causing over 80% reduction in their contribution to the total energy to fracture. This degradation occurred by embrittlement of the unbroken bridging ligaments and consequent reduction in the crack closure stress. Although the organic content of tooth enamel is very small, it is essential to crack growth toughening by facilitating the formation of unbroken ligaments and in fortifying their potency. Replicating functions of the organic content will be critical to the successful development of bio-inspired materials that are designed for fracture resistance. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  6. High thermal shock resistance of the hot rolled and swaged bulk W–ZrC alloys

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Z.M.; Liu, R.; Miao, S.; Yang, X.D. [Key Laboratory of Materials Physics, Institute of Solid State Physics, Hefei Science Center, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China, Hefei 230026 (China); Zhang, T., E-mail: zhangtao@issp.ac.cn [Key Laboratory of Materials Physics, Institute of Solid State Physics, Hefei Science Center, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China, Hefei 230026 (China); Fang, Q.F.; Wang, X.P. [Key Laboratory of Materials Physics, Institute of Solid State Physics, Hefei Science Center, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China, Hefei 230026 (China); Liu, C.S., E-mail: csliu@issp.ac.cn [Key Laboratory of Materials Physics, Institute of Solid State Physics, Hefei Science Center, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China, Hefei 230026 (China); Lian, Y.Y. [Southwestern Institute of Physics, Chengdu (China); Liu, X., E-mail: xliu@swip.ac.cn [Southwestern Institute of Physics, Chengdu (China); Luo, G.N. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2016-02-15

    The thermal shock (single shot) resistance and mechanical properties of the W–0.5wt% ZrC (WZC) alloys manufactured by ordinary sintering followed by swaging or rolling process were investigated. No cracks or surface melting were detected on the surface of the rolled WZC alloy plates after thermal shock at a power density of 0.66 GW/m{sup 2} for 5 ms, while primary intergranular cracks appear on the surface of the swaged WZC samples after thermal shock at a power density of 0.44 GW/m{sup 2} for 5 ms. Three point bending tests indicate that the rolled WZC alloy has a flexural strength of ∼2.4 GPa and a total strain of 1.8% at room temperature, which are 100% and 260% higher than those of the swaged WZC, respectively. The fracture energy density of the rolled WZC alloy is 3.23 × 10{sup 7} J/m{sup 3}, about 10 times higher than that of the swaged WZC (2.9 × 10{sup 6} J/m{sup 3}). The high thermal shock resistance of the rolled WZC alloys can be ascribed to their extraordinary ductility and plasticity. - Graphical abstract: (Left panel) surface morphology observed by optical microscope after a single pulse for 5 ms with various absorbed power densities at RT on the rolled WZC. (Right panel) curves of flexural stress versus strain at RT (a) and the calculated fracture energy (b) for the swaged WZC and rolled WZC alloys. - Highlights: • No cracks or surface melting were detected on the rolled WZC alloy samples after thermal shock at 0.66 GW/m{sup 2} for 5 ms. • Hot rolled WZC alloy plates exhibit a flexural strength of 2.4 GPa and a strain of 1.8% at RT. • The fracture energy of the rolled WZC alloy is 3.23 × 10{sup 7} J/m{sup 3} at RT, about 10 times higher than that of the swaged WZC. • A detailed analysis of the relationships between the mechanical properties and the thermal shock resistance is given.

  7. Determination of fracture toughness of human permanent and primary enamel using an indentation microfracture method.

    Science.gov (United States)

    Hayashi-Sakai, Sachiko; Sakai, Jun; Sakamoto, Makoto; Endo, Hideaki

    2012-09-01

    The purpose of the present study was to examine the fracture toughness and Vickers microhardness number of permanent and primary human enamel using the indentation microfracture method. Crack resistance and a parameter indirectly related to fracture toughness were measured in 48 enamel specimens from 16 permanent teeth and 12 enamel specimens obtained from six primary teeth. The Vickers microhardness number of the middle portion was greater than the upper portion in primary enamel. The fracture toughness was highest in the middle portion of permanent enamel, because fracture toughness greatly depends upon microstructure. These findings suggest that primary teeth are not miniature permanent teeth but have specific and characteristic mechanical properties.

  8. Traumatic fractures resulting from collisions in children and adolescents: A retrospective observational study.

    Science.gov (United States)

    Wang, Hongwei; Liu, Huan; Zhang, Song; Li, Changqing; Zhou, Yue; Liu, Jun; Ou, Lan; Xiang, Liangbi

    2018-05-01

    To investigate the incidence and pattern of child and adolescent (≤18 years old) traumatic fractures (TFs) as a result of collisions.We retrospectively reviewed 270 child and adolescent patients (228 males and 42 females aged 12.8 ± 5.1 years old) with TFs as a result of collisions admitted to our university-affiliated hospitals from 2001 to 2010. The incidence and patterns were summarized with respect to different age groups, sex, etiology, and whether the patient presented with nerve injury.The most common etiologies were struck by object (105, 38.9%) and wounded by person (74, 27.4%). The most common fracture sites were upper limb fractures (126, 46.7%) and craniofacial fractures (82, 30.4%). A total of 65 (24.1%) patients suffered a nerve injury. The frequency of early and late complications/associated injuries was 35.6% (n = 96) and 8.5% (n = 23), respectively. The mean age (P = .001) and frequency of wounded by person (P = .038) was significantly larger in male than in female patients. The frequency of earthquake injury (P lower limb fractures (P = .002) was significantly larger in females than in male patients. The frequency of upper limb fracture was significantly higher in the wounded by machine group (83.3%) than in the other groups (all P lower limb fractures was significantly higher in the earthquake injury group (64.7%) than in the other groups (all P fracture was significantly higher in the wounded by person group (54.1%) than in the other groups (all P fracture (P limb fractures were the most common etiology and site, respectively. Wounded by person and craniofacial fractures were risk factors for nerve injury. Therefore, we should pay more attention to patients wounded by person, presenting with craniofacial fracture, to find whether there is nerve injury.

  9. Experimental Study On Fracture Property Of Tapered Double Cantilever Beam Specimen With Aluminum Foam

    Directory of Open Access Journals (Sweden)

    Kim Y.C.

    2015-06-01

    Full Text Available It is indispensable to evaluate fracture energy as the bonding strength of adhesive at composite material with aluminum foam. This specimen is designed with tapered double cantilever beam by British standards (BS 7991 and ISO 11343. 4 kinds of specimens due to m values of 2, 2.5, 3 and 3.5 are manufactured and compared each other with the experimental results. Adhesive fracture energy is calculated from the formulae of British standards. The value of m is the gradient which is denoted as the length and the height of specimen. As m becomes greater at static experimental result, the maximum load becomes higher and the displacement becomes lower. And the critical fracture energy becomes higher. As m becomes less at fatigue experimental result, the displacement becomes higher and the critical fracture energy becomes higher. Fracture behavior of adhesive can be analyzed by this study and these experimental results can be applied into real field effectively. The stability on TDCB structure bonded with aluminum foam composite can be predicted by use of this experimental result. Adhesive fracture energy is calculated from the formulae of British standards. Based on correlations obtained in this study, the fracture behavior of bonded material would possibly be analyzed and aluminum foam material bonded with adhesive would be applied to a composite structure in various fields, thereby analyzing the mechanical and fracture characteristic of the material.

  10. Techniques developed to evaluate the fracture toughness offast breeder reactor duct

    International Nuclear Information System (INIS)

    Huang, F.H.; Wire, G.L.

    1979-01-01

    Large changes in strength and ductility of metals after irradiation are known to occur. The fracture toughness of irradiated metals, which is related to the combined strength and ductility of a material, may be significantly reduced and the potential for unstable crack extension increased. Therefore, the resistance of cladding and duct materials to fracture after exposure to fast neutron environments is of concern. Existing Type 316 stainless steel irradiated ducts are relatively thin and since this material retains substantial ductility, even after irradiation, the fracture behavior of the duct material cannot be analyzed by linear elastic fracture mechanics techniques. Instead, the multispecimen R-curve method and J-integral analysis were used to develop an experimental approach to evaluate the fracture toughness of thin breeder reactor duct materials irradiated at elevated temperatures. Alloy A-286 was chosen for these experiments because the alloy exhibits elastic/plastic behavior and the fracture toughness data of thicker (12 mm) specimens were available for comparison. Technical problems associated with specimen buckling and remote handling were treated in this work. The results are discussed in terms of thickness criterion for plane strain

  11. Acetabular Fracture

    Directory of Open Access Journals (Sweden)

    Chad Correa

    2017-09-01

    Full Text Available History of present illness: A 77-year-old female presented to her primary care physician (PCP with right hip pain after a mechanical fall. She did not lose consciousness or have any other traumatic injuries. She was unable to ambulate post-fall, so X-rays were ordered by her PCP. Her X-rays were concerning for a right acetabular fracture (see purple arrows, so the patient was referred to the emergency department where a computed tomography (CT scan was ordered. Significant findings: The non-contrast CT images show a minimally displaced comminuted fracture of the right acetabulum involving the acetabular roof, medial and anterior walls (red arrows, with associated obturator muscle hematoma (blue oval. Discussion: Acetabular fractures are quite rare. There are 37 pelvic fractures per 100,000 people in the United States annually, and only 10% of these involve the acetabulum. They occur more frequently in the elderly totaling an estimated 4,000 per year. High-energy trauma is the primary cause of acetabular fractures in younger individuals and these fractures are commonly associated with other fractures and pelvic ring disruptions. Fractures secondary to moderate or minimal trauma are increasingly of concern in patients of advanced age.1 Classification of acetabular fractures can be challenging. However, the approach can be simplified by remembering the three basic types of acetabular fractures (column, transverse, and wall and their corresponding radiologic views. First, column fractures should be evaluated with coronally oriented CT images. This type of fracture demonstrates a coronal fracture line running caudad to craniad, essentially breaking the acetabulum into two halves: a front half and a back half. Secondly, transverse fractures should be evaluated by sagittally oriented CT images. By definition, a transverse fracture separates the acetabulum into superior and inferior halves with the fracture line extending from anterior to posterior

  12. Ductile Tearing Resistance Indexing of Automotive Grade DP 590 Steel Sheets: EWF Testing Using DENT Specimens

    Science.gov (United States)

    Sahoo, Subhadra; Padmapriya, N.; De, Partha Sarathi; Chakraborti, P. C.; Ray, S. K.

    2018-03-01

    The essential work of fracture (EWF) method has been explored for indexing the ductile tearing resistance of DP 590 automotive grade dual-phase steel sheet both in longitudinal (L-T) and transverse (T-L) orientations. The simplest possible test and analysis procedures have been adopted. The EWF method is found to be eminently suitable for routine quality control and product development purposes for such materials. Areas for further research for improving the experimental strategy are highlighted. For the investigated steel sheet, the estimated tearing resistance is found to be distinctly higher for the L-T orientation compared to the T-L orientation; the reason thereof merits further investigation.

  13. The management of ankle fractures in patients with diabetes.

    Science.gov (United States)

    Wukich, Dane K; Kline, Alex J

    2008-07-01

    Patients with diabetes mellitus have higher complication rates following both open and closed management of ankle fractures. Diabetic patients with neuropathy or vasculopathy have higher complication rates than both diabetic patients without these comorbidities and nondiabetic patients. Unstable ankle fractures in diabetic patients without neuropathy or vasculopathy are best treated with open reduction and internal fixation with use of standard techniques. Patients with neuropathy or vasculopathy are at increased risk for both soft-tissue and osseous complications, including delayed union and nonunion. Careful soft-tissue management as well as stable, rigid internal fixation are crucial to obtaining a good outcome. Prolonged non-weight-bearing and subsequently protected weight-bearing are recommended following both operative and nonoperative management of ankle fractures in patients with diabetes.

  14. Arthroplasty for Unreconstructable Acute Fractures and Failed Fracture Fixation About the Hip and Knee in the Active Elderly: A New Paradigm.

    Science.gov (United States)

    Kyle, Richard F; Duwelius, Paul J; Haidukewych, George J; Schmidt, Andrew H

    2017-02-15

    The techniques, materials, and designs for total joint arthroplasty underwent major improvements in the past 30 years. During this time, trauma surgeons classified the severity of fractures as well as identified certain articular fractures that do not have good outcomes and have a high rate of failure after internal fixation. Advanced improvements in arthroplasty have increased its reliability and longevity. Total joint arthroplasty is becoming a standard of care for some acute articular fractures, particularly displaced femoral neck fractures in the active elderly. Total joint arthroplasty also has become the standard of care after failed internal fixation in patients who have very complicated fractures about the knee, hip, and shoulder. As the population ages, fractures worldwide continue to rapidly increase. Elderly patients have a high risk for fractures that result from falls because of their poor bone quality. The current active elderly population participates in higher risk activities than previous elderly populations, which places them at risk for more injuries. This has become both a worldwide healthcare problem and an economic problem. Surgeons need to manage fractures in the active elderly with the latest advancements in technology and patient selection to ensure rapid recovery and the reduction of complications.

  15. Inaccuracy in self-report of fractures may underestimate association with health outcomes when compared with medical record based fracture registry

    International Nuclear Information System (INIS)

    Siggeirsdottir, Kristin; Aspelund, Thor; Sigurdsson, Gunnar; Mogensen, Brynjolfur; Chang, Milan; Jonsdottir, Birna; Eiriksdottir, Gudny; Launer, Lenore J.; Harris, Tamara B.; Jonsson, Brynjolfur Y.; Gudnason, Vilmundur

    2007-01-01

    Introduction and objective Misreporting fractures in questionnaires is known. However, the effect of misreporting on the association of fractures with subsequent health outcomes has not been examined. Methods Data from a fracture registry (FR) developed from an extensive review of radiographic and medical records were related to self-report of fracture for 2,255 participants from the AGES Reykjavik Study. This data was used to determine false negative and false positive rates of self-reported fractures, correlates of misreporting, and the potential effect of the misreporting on estimates of health outcomes following fractures. Results In women, the false positive rate decreased with age as the false negative rate increased with no clear trend with age in men. Kappa values for agreement between FR and self-report were generally higher in women than men with the best agreement for forearm fracture (men 0.64 and women 0.82) and the least for rib (men 0.28 and women 0.25). Impaired cognition was a major factor associated with discordant answers between FR and self-report, OR 1.7 (95% CI: 1.3-2.1) (P < 0.0001). We estimated the effect of misreporting on health after fracture by comparison of the association of the self-report of fracture and fracture from the FR, adjusting for those factors associated with discordance. The weighted attenuation factor measured by mobility and muscle strength was 11% (95% CI: 0-24%) when adjusted for age and sex but reduced to 6% (95% CI: -10-22%) when adjusted for cognitive impairment. Conclusion Studies of hip fractures should include an independent ascertainment of fracture but for other fractures this study supports the use of self-report

  16. Interlaminar fracture of random short-fiber SMC composite

    Science.gov (United States)

    Wang, S. S.; Suemasu, H.; Zahlan, N. M.

    1984-01-01

    In the experimental phase of the present study of the interlaminar fracture behavior of a randomly oriented short fiber sheet molding compound (SMC) composite, the double cantilever beam fracture test is used to evaluate the mode I interlaminar fracture toughness of different composite thicknesses. In the analytical phase of this work, a geometrically nonlinear analysis is introduced in order to account for large deflections and nonlinear load deflection curves in the evaluation of interlaminar fracture toughness. For the SMC-R50 material studied, interlaminar toughness is an order of magnitude higher than that of unreinforced neat resin, due to unusual damage mechanisms ahead of the crack tip, together with significant fiber bridging across crack surfaces. Composite thickness effects on interlaminar fracture are noted to be appreciable, and a detailed discussion is given on the influence of SMC microstructure.

  17. Thermal fracture and pump limit of Nd: glass

    International Nuclear Information System (INIS)

    Wang Mingzhe; Ma Wen; Tan Jichun; Zhang Yongliang; Li Mingzhong; Jing Feng

    2011-01-01

    Based on published fracture experiments and 3D transient finite-element analyses, and taking the first principal stress as the criterion and the Griffith crack theory to determine the critical fracture stress, a Weibull statistical model is established to predict the fracture possibility of Nd: glass with certain pump parameters. Other issues which limit the pump power are also presented. The results show that the fracture limit of laser medium depends on the optical polishing technology. For a short pulse and high energy Nd: glass laser, taking America's polishing technology in the 1990s as reference,the pump saturation limits the pump power to 18 kW/cm 2 when the repetition rate is lower than 1 Hz, while the thermal fracture limits the pump power when the repetition rate is higher than 10 Hz. (authors)

  18. Diagnosis and Management of Common Foot Fractures.

    Science.gov (United States)

    Bica, David; Sprouse, Ryan A; Armen, Joseph

    2016-02-01

    Foot fractures are among the most common foot injuries evaluated by primary care physicians. They most often involve the metatarsals and toes. Patients typically present with varying signs and symptoms, the most common being pain and trouble with ambulation. Diagnosis requires radiographic evaluation, although emerging evidence demonstrates that ultrasonography may be just as accurate. Management is determined by the location of the fracture and its effect on balance and weight bearing. Metatarsal shaft fractures are initially treated with a posterior splint and avoidance of weight-bearing activities; subsequent treatment consists of a short leg walking cast or boot for four to six weeks. Proximal fifth metatarsal fractures have different treatments depending on the location of the fracture. A fifth metatarsal tuberosity avulsion fracture can be treated acutely with a compressive dressing, then the patient can be transitioned to a short leg walking boot for two weeks, with progressive mobility as tolerated after initial immobilization. A Jones fracture has a higher risk of nonunion and requires at least six to eight weeks in a short leg non-weight-bearing cast; healing time can be as long as 10 to 12 weeks. Great toe fractures are treated with a short leg walking boot or cast with toe plate for two to three weeks, then a rigid-sole shoe for an additional three to four weeks. Lesser toe fractures can be treated with buddy taping and a rigid-sole shoe for four to six weeks.

  19. An Inset CT Specimen for Evaluating Fracture in Small Samples of Material

    Science.gov (United States)

    Yahyazadehfar, M.; Nazari, A.; Kruzic, J.J.; Quinn, G.D.; Arola, D.

    2013-01-01

    In evaluations on the fracture behavior of hard tissues and many biomaterials, the volume of material available to study is not always sufficient to apply a standard method of practice. In the present study an inset Compact Tension (inset CT) specimen is described, which uses a small cube of material (approximately 2×2×2 mm3) that is molded within a secondary material to form the compact tension geometry. A generalized equation describing the Mode I stress intensity was developed for the specimen using the solutions from a finite element model that was defined over permissible crack lengths, variations in specimen geometry, and a range in elastic properties of the inset and mold materials. A validation of the generalized equation was performed using estimates for the fracture toughness of a commercial dental composite via the “inset CT” specimen and the standard geometry defined by ASTM E399. Results showed that the average fracture toughness obtained from the new specimen (1.23 ± 0.02 MPa•m0.5) was within 2% of that from the standard. Applications of the inset CT specimen are presented for experimental evaluations on the crack growth resistance of dental enamel and root dentin, including their fracture resistance curves. Potential errors in adopting this specimen are then discussed, including the effects of debonding between the inset and molding material on the estimated stress intensity distribution. Results of the investigation show that the inset CT specimen offers a viable approach for studying the fracture behavior of small volumes of structural materials. PMID:24268892

  20. Increased Mortality in Elderly Patients with Sarcopenia and Acetabular Fractures.

    Science.gov (United States)

    Deren, Matthew E; Babu, Jacob; Cohen, Eric M; Machan, Jason; Born, Christopher T; Hayda, Roman

    2017-02-01

    Sarcopenia is a condition of clinically relevant loss of muscle mass and function. Acetabular fractures in elderly patients are common and difficult to treat. This study aimed to determine if sarcopenia is common in elderly patients with acetabular fractures and correlates with lower-energy mechanisms of injury, higher rates of complications, and higher mortality than patients with normal muscle mass. The Rhode Island Hospital Trauma Database was queried for patients who were ≥60 years of age from 2005 to 2014 using the International Classification of Diseases, Ninth Revision, code for closed acetabular fracture, 808.0. Charts were retrospectively reviewed for demographic data, operative intervention, mechanism of injury, mortality, comorbidities, and other factors. Computed tomography (CT) was used to determine the muscle cross-sectional area and to calculate the skeletal muscle index. The database revealed 192 patients coded for acetabular fracture; of these, 181 were correctly diagnosed. Ninety-nine patients had recorded body mass index (BMI) and adequate CT scans to measure the skeletal muscle index. Forty-two patients (42.4%) had sarcopenia, and 57 patients (57.6%) did not have sarcopenia. There were no significant differences in demographic characteristics between the groups with the exception of BMI and sex. BMI was higher in patients who did not have sarcopenia (31.7 kg/m) than it was in patients with sarcopenia (23.6 kg/m) (p sarcopenia at 76.2% (32 of 42 patients) than in patients without sarcopenia at 50.9% (29 of 57 patients). Fractures in patients without sarcopenia were associated with a higher-energy mechanism of injury in 78.9% of cases compared with 52.4% of cases of patients with sarcopenia (p = 0.005). Sarcopenia was significantly associated (p = 0.0419) with increased 1-year mortality (28.6%) compared with the absence of sarcopenia (12.3%). This association was even stronger if in-hospital mortality was excluded (p = 0.00074). Finally

  1. Crack and fracture behaviour in tough ductile materials

    International Nuclear Information System (INIS)

    Venter, R.D.; Hoeppner, D.W.

    1985-10-01

    The report describes various approaches and developments pertaining to the understanding of crack and fracture behaviour in tough ductile materials. The fundamental elastic fracture mechanics concepts based on the concepts of energy, stress field, and displacement are introduced and their interrelationships demonstrated. The extension of these concepts to include elasto-plastic fracture mechanics considerations is reviewed in the context of the preferred options available for the development of appropriate design methodologies. The recommendations of the authors are directed towards the continued development of the J-integral concept. This energy-based concept, in its fundamental form, has a sound theoretical basis and as such offers the possibility of incorporating elasto-plastic fracture mechanics considerations in the crack and fracture behaviour of tough ductile materials. It must however be emphasized that the concise defintion of J becomes increasingly suspect as the crack length increases. J is not a material property, as is J IC , but emerges as a useful empirical parameter which is dependent upon the particular geometry and the loading imposed on the structure. It is proposed that 'lowest bound' J-resistance curves and the associated J-T curves be experimentally developed and employed in the design process. Improvements to these 'lowest bounds' can be developed through extensive analysis of the twin J-CTOA criteria and validation of this approach through near full scale tests

  2. Fracture toughness evaluation of select advanced replacement alloys for LWR core internals

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Lizhen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Chen, Xiang [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-08-01

    Life extension of the existing nuclear reactors imposes irradiation of high fluences to structural materials, resulting in significant challenges to the traditional reactor materials such as type 304 and 316 stainless steels. Advanced alloys with superior radiation resistance will increase safety margins, design flexibility, and economics for not only the life extension of the existing fleet but also new builds with advanced reactor designs. The Electric Power Research Institute (EPRI) teamed up with Department of Energy (DOE) to initiate the Advanced Radiation Resistant Materials (ARRM) program, aiming to develop and test degradation resistant alloys from current commercial alloy specifications by 2021 to a new advanced alloy with superior degradation resistance in light water reactor (LWR)-relevant environments by 2024. Fracture toughness is one of the key engineering properties required for core internal materials. Together with other properties, which are being examined such as high-temperature steam oxidation resistance, radiation hardening, and irradiation-assisted stress corrosion cracking resistance, the alloys will be down-selected for neutron irradiation study and comprehensive post-irradiation examinations. According to the candidate alloys selected under the ARRM program, ductile fracture toughness of eight alloys was evaluated at room temperature and the LWR-relevant temperatures. The tested alloys include two ferritic alloys (Grade 92 and an oxide-dispersion-strengthened alloy 14YWT), two austenitic stainless steels (316L and 310), four Ni-base superalloys (718A, 725, 690, and X750). Alloy 316L and X750 are included as reference alloys for low- and high-strength alloys, respectively. Compact tension specimens in 0.25T and 0.2T were machined from the alloys in the T-L and R-L orientations according to the product forms of the alloys. This report summarizes the final results of the specimens tested and analyzed per ASTM Standard E1820. Unlike the

  3. Associations of early premenopausal fractures with subsequent fractures vary by sites and mechanisms of fractures.

    Science.gov (United States)

    Honkanen, R; Tuppurainen, M; Kroger, H; Alhava, E; Puntila, E

    1997-04-01

    In a retrospective population-based study we assessed whether and how self-reported former fractures sustained at the ages of 20-34 are associated with subsequent fractures sustained at the ages of 35-57. The 12,162 women who responded to fracture questions of the baseline postal enquiry (in 1989) of the Kuopio Osteoporosis Study, Finland formed the study population. They reported 589 former and 2092 subsequent fractures. The hazard ratio (HR), with 95% confidence interval (CI), of a subsequent fracture was 1.9 (1.6-2.3) in women with the history of a former fracture compared with women without such a history. A former low-energy wrist fracture was related to subsequent low-energy wrist [HR = 3.7 (2.0-6.8)] and high-energy nonwrist [HR = 2.4 (1.3-4.4)] fractures, whereas former high-energy nonwrist fractures were related only to subsequent high-energy nonwrist [HR = 2.8 (1.9-4.1)] but not to low-energy wrist [HR = 0.7 (0.3-1.8)] fractures. The analysis of bone mineral density (BMD) data of a subsample of premenopausal women who underwent dual x-ray absorptiometry (DXA) during 1989-91 revealed that those with a wrist fracture due to a fall on the same level at the age of 20-34 recorded 6.5% lower spinal (P = 0.140) and 10.5% lower femoral (P = 0.026) BMD than nonfractured women, whereas the corresponding differences for women with a former nonwrist fracture due to high-energy trauma were -1.8% (P = 0.721) and -2.4% (P = 0. 616), respectively. Our results suggest that an early premenopausal, low-energy wrist fracture is an indicator of low peak BMD which predisposes to subsequent fractures in general, whereas early high-energy fractures are mainly indicators of other and more specific extraskeletal factors which mainly predispose to same types of subsequent fractures only.

  4. Are certain fractures at increased risk for compartment syndrome after civilian ballistic injury?

    Science.gov (United States)

    Meskey, Thomas; Hardcastle, John; O'Toole, Robert V

    2011-11-01

    Compartment syndrome after ballistic fracture is uncommon but potentially devastating. Few data are available to help guide clinicians regarding risk factors for developing compartment syndrome after ballistic fractures. Our primary hypothesis was that ballistic fractures of certain bones would be at higher risk for development of compartment syndrome. A retrospective review at a Level I trauma center from 2001 through 2007 yielded 650 patients with 938 fractures resulting from gunshots. We reviewed all operative notes, clinic notes, discharge summaries, and data from our prospective trauma database. Cases in which the attending orthopedic surgeon diagnosed compartment syndrome and performed fasciotomy were considered cases with compartment syndrome. We excluded all prophylactic fasciotomies. Univariate analyses were conducted to identify risk factors associated with development of compartment syndrome. Twenty-six (2.8%) of the 938 fractures were associated with compartment syndrome. Only fibular (11.6%) and tibial (11.4%) fractures had incidence significantly higher than baseline for all ballistic fractures (p Ballistic fractures of the fibula and tibia are at increased risk for development of compartment syndrome over other ballistic fractures. We recommend increased vigilance when treating these injuries, particularly if the fracture is in the proximal aspect of the bone or is associated with vascular injury.

  5. Surgical Management of a Mandible Subcondylar Fracture

    Directory of Open Access Journals (Sweden)

    Dong Hee Kang

    2012-07-01

    Full Text Available Open reduction and anatomic reduction can create better function for the temporomandibular joint, compared with closed treatment in mandible fracture surgery. Therefore, the double miniplate fixation technique via mini-retromandibular incision was used in order to make the most stable fixation when performing subcondylar fracture surgery. Those approaches provide good visualization of the subcondyle from the posterior edge of the ramus, allow the surgeon to work perpendicularly to the fracture, and enable direct fracture management. Understanding the biomechanical load in the fixation of subcondylar fractures is also necessary in order to optimize fixation methods. Therefore, we measured the biomechanical loads of four different plate fixation techniques in the experimental model regarding mandibular subcondylar fractures. It was found that the loads measured in the two-plate fixation group with one dynamic compression plate (DCP and one adaption plate showed the highest deformation and failure loads among the four fixation groups. The loads measured in the one DCP plate fixation group showed higher deformation and failure loads than the loads measured in the two adaption plate fixation group. Therefore, we conclude that the selection of the high profile plate (DCP is also important in order to create a stable load in the subcondylar fracture.

  6. Temporal distribution of alcohol related facial fractures.

    Science.gov (United States)

    Lee, Kai H; Qiu, Michael; Sun, Jiandong

    2017-11-01

    This study aimed to address 2 important aspects of temporal pattern in alcohol-related facial fractures: (1) comparison of temporal pattern of alcohol-related facial fracture (alcohol group) presentation with non-alcohol-related fracture (non-alcohol group) presentation; (2) temporal pattern of patient demographic characteristics, injury characteristics, and surgical management in the alcohol group presentation. This study retrospectively examined the Victorian admitted episodes data set (VAED) for the years 2010 to 2013. VAED is a standardized set of data collected during all hospital presentations in Victoria. The study found higher incidence of alcohol-related facial fracture presentations during weekends and during the summer and spring months compared with non-alcohol-related fractures (statistically significant). Alcohol-related facial fractures are more likely to involve male patients in the 20- to 29-year age group, occur as a result of interpersonal violence, and require shorter hospital stays during weekend admissions (statistically significant). No statistically significant relationship has been observed in seasonal variation across all variables. This study found distinct characteristics in temporal distribution of alcohol-related facial fractures. These characteristics are, in particular, significant in weekend trauma admissions. Such information is important in workforce planning, resource distribution, and implementation of injury prevention programs. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Mediterranean Diet and Hip Fracture in Swedish Men and Women.

    Science.gov (United States)

    Byberg, Liisa; Bellavia, Andrea; Larsson, Susanna C; Orsini, Nicola; Wolk, Alicja; Michaëlsson, Karl

    2016-12-01

    A Mediterranean diet, known to have beneficial effects on cardiovascular health, may also influence the risk of hip fracture although previous studies present discrepant results. We therefore aimed to determine whether the rate of hip fracture was associated with degree of adherence to a Mediterranean diet. We combined two Swedish cohort studies consisting of 37,903 men and 33,403 women (total n = 71,333, mean age 60 years) free of previous cardiovascular disease and cancer who answered a medical and a food-frequency questionnaire in 1997. A modified Mediterranean diet score (mMED; range, 0 to 8 points) was created based on high consumption of fruits and vegetables, legumes and nuts, whole grains, fermented dairy products, fish, and olive/rapeseed oil, moderate intake of alcohol, and low intake of red and processed meat. Incident hip fractures between January 1, 1998, and December 31, 2012, were retrieved from the National Patient Register. Hazard ratios (HRs) and 95% confidence intervals (CIs) adjusted for potential confounders were calculated using Cox proportional hazards regression. Differences in age at hip fracture were calculated using multivariable Laplace regression. During follow-up, 3175 hip fractures occurred at a median age of 73.3 years. One unit increase in the mMED was associated with 6% lower hip fracture rate (adjusted HR = 0.94; 95% CI, 0.92 to 0.96) and with a 3-month higher median age at hip fracture (50th percentile difference = 2.8 months; 95% CI, 1.4 to 4.2). Comparing the highest quintile of adherence to the mMED (6 to 8 points) with the lowest (0 to 2 points) conferred an adjusted HR of hip fracture of 0.78 (95% CI, 0.69 to 0.89) and a 12-month higher median age of hip fracture (50th percentile difference = 11.6 months; 95% CI, 4.2 to 19.0). Results were similar in men and women. We conclude that higher adherence to a Mediterranean-like diet is associated with lower risk of future hip fracture. © 2016 American Society for

  8. On the interfacial fracture of porcelain/zirconia and graded zirconia dental structures.

    Science.gov (United States)

    Chai, Herzl; Lee, James J-W; Mieleszko, Adam J; Chu, Stephen J; Zhang, Yu

    2014-08-01

    Porcelain fused to zirconia (PFZ) restorations are widely used in prosthetic dentistry. However, their susceptibility to fracture remains a practical problem. The failure of PFZ prostheses often involves crack initiation and growth in the porcelain, which may be followed by fracture along the porcelain/zirconia (P/Z) interface. In this work, we characterized the process of fracture in two PFZ systems, as well as a newly developed graded glass-zirconia structure with emphases placed on resistance to interfacial cracking. Thin porcelain layers were fused onto Y-TZP plates with or without the presence of a glass binder. The specimens were loaded in a four-point-bending fixture with the thin porcelain veneer in tension, simulating the lower portion of the connectors and marginal areas of a fixed dental prosthesis (FDP) during occlusal loading. The evolution of damage was observed by a video camera. The fracture was characterized by unstable growth of cracks perpendicular to the P/Z interface (channel cracks) in the porcelain layer, which was followed by stable cracking along the P/Z interface. The interfacial fracture energy GC was determined by a finite-element analysis taking into account stress-shielding effects due to the presence of adjacent channel cracks. The resulting GC was considerably less than commonly reported values for similar systems. Fracture in the graded Y-TZP samples occurred via a single channel crack at a much greater stress than for PFZ. No delamination between the residual glass layer and graded zirconia occurred in any of the tests. Combined with its enhanced resistance to edge chipping and good esthetic quality, graded Y-TZP emerges as a viable material concept for dental restorations. Copyright © 2014 Acta Materialia Inc. All rights reserved.

  9. Probabilistic Risk Assessment for Astronaut Post Flight Bone Fracture

    Science.gov (United States)

    Lewandowski, Beth; Myers, Jerry; Licata, Angelo

    2015-01-01

    Introduction: Space flight potentially reduces the loading that bone can resist before fracture. This reduction in bone integrity may result from a combination of factors, the most common reported as reduction in astronaut BMD. Although evaluating the condition of bones continues to be a critical aspect of understanding space flight fracture risk, defining the loading regime, whether on earth, in microgravity, or in reduced gravity on a planetary surface, remains a significant component of estimating the fracture risks to astronauts. This presentation summarizes the concepts, development, and application of NASA's Bone Fracture Risk Module (BFxRM) to understanding pre-, post, and in mission astronaut bone fracture risk. The overview includes an assessment of contributing factors utilized in the BFxRM and illustrates how new information, such as biomechanics of space suit design or better understanding of post flight activities may influence astronaut fracture risk. Opportunities for the bone mineral research community to contribute to future model development are also discussed. Methods: To investigate the conditions in which spaceflight induced changes to bone plays a critical role in post-flight fracture probability, we implement a modified version of the NASA Bone Fracture Risk Model (BFxRM). Modifications included incorporation of variations in physiological characteristics, post-flight recovery rate, and variations in lateral fall conditions within the probabilistic simulation parameter space. The modeled fracture probability estimates for different loading scenarios at preflight and at 0 and 365 days post-flight time periods are compared. Results: For simple lateral side falls, mean post-flight fracture probability is elevated over mean preflight fracture probability due to spaceflight induced BMD loss and is not fully recovered at 365 days post-flight. In the case of more energetic falls, such as from elevated heights or with the addition of lateral movement

  10. Fracture toughness testing on ferritic alloys using the electropotential technique

    International Nuclear Information System (INIS)

    Huang, F.H.; Wire, G.L.

    1981-01-01

    Fracture toughness measurements as done conventionally require large specimens (5 x 5 x 2.5 cm) which would be prohibitively expensive to irradiate over the fluence and temperature ranges required for first wall design. To overcome this difficulty a single specimen technique for J intergral fracture toughness measurements on miniature specimens (1.6 cm OD x 0.25 cm thick) was developed. Comparisons with specimens three times as thick show that the derived J/sub 1c/ is constant, validating the specimen for first wall applications. The electropotential technique was used to obtain continuous crack extension measurements, allowing a ductile fracture resistence curve to be constructed from a single specimen. The irradiation test volume required for fracture toughness measurements using both miniature specimens and single specimen J measurements was reduced a factor of 320, making it possible to perform a systematic exploration of irradiation temperature and dose variables as required for qualification of HT-9 and 9Cr-1Mo base metal and welds for first wall application. Fracture toughness test results for HT-9 and 9Cr-1Mo from 25 to 539 0 C are presented to illustrate the single specimen technique

  11. Management of displaced comminuted patellar fracture with titanium cable cerclage.

    Science.gov (United States)

    Yang, Li; Yueping, Ouyang; Wen, Yuan

    2010-08-01

    Management of a displaced comminuted patellar fracture is challenging. Tension band wiring and lag screw fixation are not suitable for such a fracture pattern. Stainless steel wiring with various configurations has been the mainstay of treatment. However, issues of loss of fixation and breakage of wire have not been resolved yet. Partial or total patellectomy is the last resort with a detrimental effect on quadriceps power. Braided titanium cable is stronger in tensile strength and better in fatigue resistance than the stainless steel monofilament wire, and the tension of fixation could be controlled by a graded instrument in its application. We used titanium cable to treat 21 consecutive patients with displaced comminuted patellar fracture. Patients were followed up for a mean period of 24 months (12 to 32 months). The mean score at the final follow-up was 27 points (25 to 30) using the Böstman method. There was no complication except breakage of one cable at the sixth week after the operation and the fracture had united despite the breakage. This technique is simple and effective for these difficult fractures and avoided prolonged immobilisation of the knee. Copyright 2010 Elsevier B.V. All rights reserved.

  12. Database for Hydraulically Conductive Fractures. Update 2010

    International Nuclear Information System (INIS)

    Tammisto, E.; Palmen, J.

    2011-02-01

    Posiva flow logging (PFL) with 0.5 m test interval and made in 10 cm steps can be used for exact depth determination of hydraulically conductive fractures. Together with drillhole wall images and fracture data from core logging PFL provides possibilities to detect single conductive fractures. In this report, the results of PFL are combined to the fracture data in drillholes OL-KR49 .. OL-KR53, OL-KR50B, OL-KR52B and OLKR53B and pilot holes ONK-PH11 - ONK-PH13. The results are used mainly in development of hydroDFN- models. The conductive fractures were first recognised from the PFL data and digital drillhole images and then the fractures from the core logging corresponding to the ones picked from the digital drillhole images were identified. The conductive fractures were recognised from the images primarily based on openness of fractures or a visible flow in the image. In most of the cases of measured flow, no tails of flow were seen in the image. In these cases, the conductive fractures were recognised from the image based on openness of fractures and a matching depth. According to the results the hydraulically conductive fractures/zones can be distinguished from the drillhole wall images in most cases. An important phase in the work is to calibrate the depth of the image and the flow logging with the sample length. The hydraulic conductivity is clearly higher in the upper part of the bedrock in the depth range 0-150 m below sea level than deeper in the bedrock. The frequency of hydraulically conductive fractures detected in flow logging (T > 10 -10 -10 -9 m 2 /s) in depth range 0-150 m varies from 0.07 to 0.84 fractures/meter of sample length. Deeper in the rock the conductive fractures are less frequent, but occur often in groups of few fractures. In drillholes OL-KR49 .. OL-KR53, OL-KR50B, OL-KR52B and OL-KR53B about 8.5 % of all fractures and 4.4 % of the conductive fractures are within HZ-structures. (orig.)

  13. Concepts and possibilities of fracture mechanics for fracture safety assessment

    International Nuclear Information System (INIS)

    Blauel, J.

    1980-01-01

    In very tough materials for pressure vessels and pipelines of nuclear plants, cracking begins in a stable manner and only after macroscopic plastic deformations and crack blunting. It is possible to describe this elasto-plastic fracture behaviour and to quantify the safety margin compared to the assessment criteria based on linear elastic stressing and initiation by the concept of the J integral, the crack peak width and the crack resistance Jsub(R) curve. The numerous problems of details still open and the partly very limited validity range should not prevent the further investigation into the great possibilities of this concept and making greater use of the interpretation of large scale tests. (orig./RW) [de

  14. Risks of subsequent contralateral fractures of the trochanteric region in elderly.

    Science.gov (United States)

    Pogliacomi, Francesco; Pellegrini, Andrea; Tacci, Fabrizio; Pedrini, Martina Francesca; Costantino, Cosimo; Pedrazzini, Alessio; Pedrazzi, Giuseppe; Lauretani, Fulvio; Vaienti, Enrico; Ceccarelli, Francesco

    2017-01-16

    Fractures in elderly are always a dramatic event and the healing is often not complete. In a context of bone fragility, repeated fractures are a growing problem in the industrialized world, in which the mean age of population is increasing. The aim of this study was to identify those general factors which may increase the risk of subsequent trochanteric fractures after an initial lesion. Three-hundred and thirty-one patients who underwent intramedullary fixation for trochanteric fractures between January 2012 and December 2013 were studied. Forty subjects yet alive (group 1), affected by a subsequent contralateral hip fracture, were compared with 202 patients (group 2) affected by isolated trochanteric fracture. Days of hospitalization before surgery, hospitalization, period of rehabilitation, type of discharge and comorbidities, that are reported in literature as possible risk factors for hip refracture, were analyzed. In addition, all patients were interviewed in order to assess if a therapy for osteoporosis was prescribed after the initial fracture and how their gait had been modified by fractures. Days of hospitalization before surgery, hospitalization, period of rehabilitation and type of discharge were not predictive factors for subsequent fractures, as well as diabetes mellitus, hypertension and cardiac diseases. The presence of neurologic and respiratory diseases were associated to a higher risk of refractures, as well as the absence of specific medical treatment for osteoporosis. Neurologic and respiratory comorbidities and the absence of osteoporosis medical treatment are the variables associated to a higher risk of contralateral fractures. Physicians can do more in terms of prevention and strategies must consider these risk factors.

  15. Interlaminar fracture toughness for composite materials

    International Nuclear Information System (INIS)

    Lee, Kang Yong; Kwon, Soon Man

    1991-01-01

    The new equation of energy release rate for a double cantilever beam specimen is proposed within the framework of the higher order shear deformable plate theory. The interlaminar fracture toughnesses by present theory, ASTM round robin test method and acoustic emission method are compared for thermoset Graphite/Epoxy and thermoplastic AS4/PEEK composites. As a result, the interlaminar fracture toughness values by present theory show good agreement within 5% when compared with ones by ASTM method and it is shown that ones by acoustic emission method yield the lower values than ones by ASTM method. It is observed that the interlaminar fracture toughness of thermoplastic AS4/PEEK composite is about ten times larger than one of thermoset Graphite/Epoxy composite. (Author)

  16. Occurrence of secondary fracture around intramedullary nails used for trochanteric hip fractures: a systematic review of 13,568 patients.

    Science.gov (United States)

    Norris, Rory; Bhattacharjee, Dhritiman; Parker, Martyn J

    2012-06-01

    A sliding hip screw (SHS) is currently the treatment of choice for trochanteric hip fractures, largely due to the low incidence of complications. An alternative treatment is the use of intramedullary proximal femoral nails. Unfortunately these implants have been associated with a risk of later fracture around the implant. The aim of this study was to see if any improvements have been made to the current intramedullary nails, to reduce the incidence of secondary fracture around the distal tip of the nail. We analysed data related to 13,568 patients from 89 studies, focusing on the incidence of post operative secondary femoral shaft fracture following the use of intramedullary nails in the fixation of trochanteric hip fractures. The overall reported incidence of secondary fracture around the nail was 1.7%. The incidence of fracture has reduced in the 3rd generation Gamma nails when compared to the older Gamma nail (1.7% versus 2.6%, p value 0.03). However, the incidence of secondary fracture in the 3rd generation Gamma nails is still significantly higher than the other brands of short nail (1.7% versus 0.7%, p value 0.0005). Long nails had a slight tendency towards a lower risk of fracture although the difference was not statistically significant (1.1% versus 1.7%, p value 0.28). There was a significantly lower risk of fracture for those nails with a biaxial fixation as opposed to uniaxial fixation (0.6% versus 1.9%, p value fracture around a proximal femoral nail is one of the most significant of fracture healing complications, and this study suggests that continuing design changes to this method of fixation has reduced the risk of this complication occurring. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Facilitation of bone resorption activities in synovial lavage fluid patients with mandibular condyle fractures.

    Science.gov (United States)

    Takano, H; Takahashi, T; Nakata, A; Nogami, S; Yusa, K; Kuwajima, S; Yamazaki, M; Fukuda, M

    2016-05-01

    The aim of this study was to investigate the bone resorption effect of the mediators delivered in joint cavity of patients with mandibular condyle fractures by detecting osteoclast markers using cellular biochemistry methods, and by analysing bone resorption activities via inducing osteoclast differentiation of the infiltrated cells from arthrocentesis. Sixteen joints in 10 patients with mandibular condyle fractures were evaluated. The control group consisted of synovial fluid (SF) samples from seven joints of four volunteers who had no clinical signs or symptoms involving the temporomandibular joint (TMJ) or disc displacement. We collected SF cells from all patients during therapeutic arthrocentesis. The infiltrating cells from TMJ SF were cultured, differentiated into tartrate-resistant acid phosphatase (TRAP)-positive osteoclast-like cells and examined bone resorption activities. We also investigated factors related to osteoclast induction of SF, using ELISA procedures. Osteoclast-like cells were induced from the SF cells obtained from all patients with condylar fractures. These multinucleated giant cells were positive for TRAP and actin, and had the ability to absorb dentin slices. The levels of macrophage colony-stimulating factor (M-CSF), prostaglandin E2 (PGE2), soluble form of receptor activator of nuclear factor kappa-B ligand (sRANKL) and osteoprotegerin (OPG), in SF samples from the patients, were significantly higher than in the controls. These findings indicate that bone resorption activities in SF from patients with mandibular condyle fractures were upregulated and may participate in the pathogenesis and wound healing. © 2016 The Authors. Journal of Oral Rehabilitation Published by John Wiley & Sons Ltd.

  18. Radiographic classification for fractures of the fifth metatarsal base

    International Nuclear Information System (INIS)

    Mehlhorn, Alexander T.; Zwingmann, Joern; Hirschmueller, Anja; Suedkamp, Norbert P.; Schmal, Hagen

    2014-01-01

    Avulsion fractures of the fifth metatarsal base (MTB5) are common fore foot injuries. Based on a radiomorphometric analysis reflecting the risk for a secondary displacement, a new classification was developed. A cohort of 95 healthy, sportive, and young patients (age ≤ 50 years) with avulsion fractures of the MTB5 was included in the study and divided into groups with non-displaced, primary-displaced, and secondary-displaced fractures. Radiomorphometric data obtained using standard oblique and dorso-plantar views were analyzed in association with secondary displacement. Based on this, a classification was developed and checked for reproducibility. Fractures with a longer distance between the lateral edge of the styloid process and the lateral fracture step-off and fractures with a more medial joint entry of the fracture line at the MTB5 are at higher risk to displace secondarily. Based on these findings, all fractures were divided into three types: type I with a fracture entry in the lateral third; type II in the middle third; and type III in the medial third of the MTB5. Additionally, the three types were subdivided into an A-type with a fracture displacement <2 mm and a B-type with a fracture displacement ≥ 2 mm. A substantial level of interobserver agreement was found in the assignment of all 95 fractures to the six fracture types (κ = 0.72). The secondary displacement of fractures was confirmed by all examiners in 100 %. Radiomorphometric data may identify fractures at risk for secondary displacement of the MTB5. Based on this, a reliable classification was developed. (orig.)

  19. Radiographic classification for fractures of the fifth metatarsal base

    Energy Technology Data Exchange (ETDEWEB)

    Mehlhorn, Alexander T.; Zwingmann, Joern; Hirschmueller, Anja; Suedkamp, Norbert P.; Schmal, Hagen [University of Freiburg Medical Center, Department of Orthopaedic Surgery, Freiburg (Germany)

    2014-04-15

    Avulsion fractures of the fifth metatarsal base (MTB5) are common fore foot injuries. Based on a radiomorphometric analysis reflecting the risk for a secondary displacement, a new classification was developed. A cohort of 95 healthy, sportive, and young patients (age ≤ 50 years) with avulsion fractures of the MTB5 was included in the study and divided into groups with non-displaced, primary-displaced, and secondary-displaced fractures. Radiomorphometric data obtained using standard oblique and dorso-plantar views were analyzed in association with secondary displacement. Based on this, a classification was developed and checked for reproducibility. Fractures with a longer distance between the lateral edge of the styloid process and the lateral fracture step-off and fractures with a more medial joint entry of the fracture line at the MTB5 are at higher risk to displace secondarily. Based on these findings, all fractures were divided into three types: type I with a fracture entry in the lateral third; type II in the middle third; and type III in the medial third of the MTB5. Additionally, the three types were subdivided into an A-type with a fracture displacement <2 mm and a B-type with a fracture displacement ≥ 2 mm. A substantial level of interobserver agreement was found in the assignment of all 95 fractures to the six fracture types (κ = 0.72). The secondary displacement of fractures was confirmed by all examiners in 100 %. Radiomorphometric data may identify fractures at risk for secondary displacement of the MTB5. Based on this, a reliable classification was developed. (orig.)

  20. Anisotropy of fracture toughness of austenitic high nitrogen chromium-manganese steel

    International Nuclear Information System (INIS)

    Balitskii, A.I.; Pokhmurskii, V.I.; Diener, M.; Magdowski, R.; Speidel, M.O.

    1999-01-01

    The anisotropy of mechanical properties, in particular of the fracture toughness measured by the J-integral method, is demonstrated for industrially manufactured high strength retaining rings made from the nitrogen alloyed steel 18Mn18Cr. The RT-orientation turns out to be the weakest with regard to the resistance of the material to stable crack growth. The fracture toughness results are compared with results from calorimetric measurements. Here, also an orientation dependence of the heat irradiation energy is observed, clearly showing the same ranking of specimen orientation as the toughness data suggest. (orig.)