WorldWideScience

Sample records for higher energy x-rays

  1. Dual Energy X-Ray CT by Compton Scattering Hard X-Ray Source

    CERN Document Server

    Uesaka, Mitsuru; Kaneyasu, Tatsuo; Torikoshi, Masami

    2005-01-01

    We have developed a compact Compton scattering hard X-ray source at Nuclear Engineering Research Laboratory, University of Tokyo. The compact hard X-ray source can produce tunable monochromatic hard X-rays. The monochromatic hard X-rays are required in large field of medical and biological applications. We are planning to perform dual-energy X-ray CT, which enables us to measure atomic number Z distribution and electron density re distribution in a material. The hard X-ray source has an advantage to perform dual-energy X-ray CT. The X-ray energy can be changed quickly by introducing a fundamental frequency and a second harmonic frequency lasers. This quick energy change is indispensable to medical imaging and very difficult in a large SR light source and others. The information on the atomic number and electron density will be used for treatment plan in radiotherapy as well as for identification of materials in a nondestructive test. We examined applicability of the dual-energy X-ray CT for atomic number meas...

  2. Fundamentals of energy dispersive X-ray analysis

    CERN Document Server

    Russ, John C; Kiessling, R; Charles, J

    1984-01-01

    Fundamentals of Energy Dispersive X-ray Analysis provides an introduction to the fundamental principles of dispersive X-ray analysis. It presents descriptions, equations, and graphs to enable the users of these techniques to develop an intuitive and conceptual image of the physical processes involved in the generation and detection of X-rays. The book begins with a discussion of X-ray detection and measurement, which is accomplished by one of two types of X-ray spectrometer: energy dispersive or wavelength dispersive. The emphasis is on energy dispersive spectrometers, given their rather wid

  3. Low Energy X-Ray Diagnostics - 1981.

    Science.gov (United States)

    1981-01-01

    ray Analysis, 18, 26 (1975). practicA !ity of thermal recording of intense x-rays. 2. R.P. Godwin, Adv. in X-rays Analysis, 19, 533 Many optical...the 15. T. W. Barbee Jr., in "National Science Foundation behavior of LSM dispersion elements. - Twenty Sixth Annual Report for Fiscal Year Extension

  4. High energy X-ray phase and dark-field imaging using a random absorption mask.

    Science.gov (United States)

    Wang, Hongchang; Kashyap, Yogesh; Cai, Biao; Sawhney, Kawal

    2016-07-28

    High energy X-ray imaging has unique advantage over conventional X-ray imaging, since it enables higher penetration into materials with significantly reduced radiation damage. However, the absorption contrast in high energy region is considerably low due to the reduced X-ray absorption cross section for most materials. Even though the X-ray phase and dark-field imaging techniques can provide substantially increased contrast and complementary information, fabricating dedicated optics for high energies still remain a challenge. To address this issue, we present an alternative X-ray imaging approach to produce transmission, phase and scattering signals at high X-ray energies by using a random absorption mask. Importantly, in addition to the synchrotron radiation source, this approach has been demonstrated for practical imaging application with a laboratory-based microfocus X-ray source. This new imaging method could be potentially useful for studying thick samples or heavy materials for advanced research in materials science.

  5. Bone age assessment by dual-energy X-ray absorptiometry in children: An alternative for X-ray?

    NARCIS (Netherlands)

    D.H.M. Heppe (Denise); H.R. Taal (Rob); G.D.S. Ernst (Gesina); E.L.T. van den Akker (Erica); M.H. Lequin (Maarten); A.C.S. Hokken-Koelega (Anita); J.J.M. Geelhoed (Miranda); V.W.V. Jaddoe (Vincent)

    2012-01-01

    textabstractObjective: The aim of the study was to validate dual-energy X-ray absorptiometry (DXA) as a method to assess bone age in children. Methods: Paired dual-energy X-ray absorptiometry (DXA) scans and X-rays of the left hand were performed in 95 children who attended the paediatric

  6. Quantitative energy-dispersive electron probe X-ray microanalysis ...

    Indian Academy of Sciences (India)

    An energy-dispersive electron probe X-ray microanalysis (ED-EPMA) technique using an energy-dispersive X-ray detector with an ultra-thin window, designated as low-Z particle EPMA, has been developed. The low-Z particle EPMA allows the quantitative determination of concentrations of low-Z elements such as C, N and ...

  7. An edge-on charge-transfer design for energy-resolved x-ray detection

    Science.gov (United States)

    Shi, Zaifeng; Yang, Haoyu; Cong, Wenxiang; Wang, Ge

    2016-06-01

    As an x-ray beam goes through the human body, it will collect important information via interaction with tissues. Since this interaction is energy-sensitive, the state-of-the-art spectral CT technologies provide higher quality images of biological tissues with x-ray energy information (or spectral information). With existing energy-integrating technologies, a large fraction of energy information is ignored in the x-ray detection process. Although the recently proposed photon-counting technology promises to achieve higher image quality at a lower radiation dose, it suffers from limitations in counting rate, performance uniformity, and fabrication cost. In this paper, we focus on an alternative approach to resolve the energy distribution of transmitted x-ray photons. First, we analyze the x-ray attenuation in a silicon substrate and describe a linear approximation model for x-ray detection. Then, we design an edge-on architecture based on the proposed energy-resolving model. In our design, the x-ray-photon-induced charges are transferred sequentially resembling the working process of a CCD camera. Finally, we numerically evaluate the linear approximation of x-ray attenuation and derive the energy distribution of x-ray photons. Our simulation results show that the proposed energy-sensing approach is feasible and has the potential to complement the photon-counting technology.

  8. The color of X-rays: Spectral X-ray computed tomography using energy sensitive pixel detectors

    NARCIS (Netherlands)

    Schioppa, E.J.

    2014-01-01

    Energy sensitive X-ray imaging detectors are produced by connecting a semiconductor sensor to a spectroscopic pixel readout chip. In this thesis, the applicability of such detectors to X-ray Computed Tomography (CT) is studied. A prototype Medipix based silicon detector is calibrated using X-ray

  9. High energy resolution off-resonant X-ray spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Wojciech, Blachucki [Univ. of Fribourg (Switzerland). Dept. of Physics

    2015-10-16

    This work treats of the high energy resolution off-resonant X-ray spectroscopy (HEROS) method of determining the density of unoccupied electronic states in the vicinity of the absorption edge. HEROS is an alternative to the existing X-ray absorption spectroscopy (XAS) methods and opens the way for new studies not achievable before.

  10. X-ray characterization by energy-resolved powder diffraction

    Directory of Open Access Journals (Sweden)

    G. Cheung

    2016-08-01

    Full Text Available A method for single-shot, nondestructive characterization of broadband x-ray beams, based on energy-resolved powder diffraction, is described. Monte-Carlo simulations are used to simulate data for x-ray beams in the keV range with parameters similar to those generated by betatron oscillations in a laser-driven plasma accelerator. The retrieved x-ray spectra are found to be in excellent agreement with those of the input beams for realistic numbers of incident photons. It is demonstrated that the angular divergence of the x rays can be deduced from the deviation of the detected photons from the Debye-Scherrer rings which would be produced by a parallel beam. It is shown that the angular divergence can be measured as a function of the photon energy, yielding the angularly resolved spectrum of the input x-ray beam.

  11. Advantages of intermediate X-ray energies in Zernike phase contrast X-ray microscopy.

    Science.gov (United States)

    Wang, Zhili; Gao, Kun; Chen, Jian; Hong, Youli; Ge, Xin; Wang, Dajiang; Pan, Zhiyun; Zhu, Peiping; Yun, Wenbing; Jacobsen, Chris; Wu, Ziyu

    2013-01-01

    Understanding the hierarchical organizations of molecules and organelles within the interior of large eukaryotic cells is a challenge of fundamental interest in cell biology. Light microscopy is a powerful tool for observations of the dynamics of live cells, its resolution attainable is limited and insufficient. While electron microscopy can produce images with astonishing resolution and clarity of ultra-thin (microscopy offers superior imaging resolution compared to light microscopy, and unique capability of nondestructive three-dimensional imaging of hydrated unstained biological cells, complementary to existing light and electron microscopy. Until now, X-ray microscopes operating in the "water window" energy range between carbon and oxygen k-shell absorption edges have produced outstanding 3D images of cryo-preserved cells. The relatively low X-ray energy (phase contrast can overcome the above limitations and reduces radiation dose to the specimen. Using a hydrated model cell with an average chemical composition reported in literature, we calculated the image contrast and the radiation dose for absorption and Zernike phase contrast, respectively. The results show that an X-ray microscope operating at ~2.5 keV using Zernike phase contrast offers substantial advantages in terms of specimen size, radiation dose and depth-of-focus. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Comprehensive x-ray spectral code for high energy astrophysics

    Energy Technology Data Exchange (ETDEWEB)

    Liedahl, D A; Fournier, K B; Mauche, C W

    2000-08-18

    The aim of this project has been to develop a spectral analysis tool with a level of quality and completeness commensurate to that expected in data from the current generation of X-ray observatories. The code is called LXSS (Livermore X-Ray Spectral Synthesizer). X-ray-emitting astrophysical plasmas are rarely, if ever, in LTE, so they have adopted the detailed level accounting approach, in which rates for processes that populate or depopulate atomic energy levels are treated explicitly. This entails the generation of a large quantity of atomic data, most of which is calculated using ''in-house'' computer codes. Calculations are benchmarked against laboratory data, and spectral models have been used to provide first-time interpretations of astrophysical X-ray spectra. The design of a versatile graphical user interface that allows access to and manipulation of the atomic database comprises the second major part of the project.

  13. Portable energy dispersive X-ray fluorescence and X-ray diffraction and radiography system for archaeometry

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza Cuevas, Ariadna, E-mail: ariadna@mail.or [Archaeometry Laboratory, Colegio Universitario San Geronimo de La Habana, Obispo, entre San Ignacio y Mercaderes, Habana Vieja, cp 10 100, Havana (Cuba); Perez Gravie, Homero, E-mail: homero.perezgravie@mail.co [Archaeometry Laboratory, Colegio Universitario San Geronimo de La Habana, Obispo, entre San Ignacio y Mercaderes, Habana Vieja, cp 10 100, Havana (Cuba)

    2011-03-21

    Starting on a laboratory developed portable X-ray fluorescence (PXRF) spectrometer; three different analytical results can be performed: analysis of chemical elements, analysis of major chemical crystalline phase and structural analysis, which represents a contribution to a new, low cost development of portable X-ray analyzer; since these results are respectively obtained with independent equipments for X-ray fluorescence, X-ray diffraction and radiography. Detection limits of PXRF were characterized using standard reference materials for ceramics, glass, bronze and bones, which are the main materials requiring quantitative analysis in art and archeological objects. A setup for simultaneous energy dispersive X-ray fluorescence and diffraction (ED (XRF-XRD)) in the reflection mode has been tested for in situ and non-destructive analysis according to the requirements of art objects inspection. The system uses a single low power X-ray tube and an X-ray energy dispersive detector to measure X-ray diffraction spectrum at a fixed angle. Application to the identification of jadeite-jade mineral in archeological objects by XRD is presented. A local high resolution radiography image obtained with the same low power X-ray tube allows for studies in painting and archeological bones.

  14. Energy weighted x-ray dark-field imaging.

    Science.gov (United States)

    Pelzer, Georg; Zang, Andrea; Anton, Gisela; Bayer, Florian; Horn, Florian; Kraus, Manuel; Rieger, Jens; Ritter, Andre; Wandner, Johannes; Weber, Thomas; Fauler, Alex; Fiederle, Michael; Wong, Winnie S; Campbell, Michael; Meiser, Jan; Meyer, Pascal; Mohr, Jürgen; Michel, Thilo

    2014-10-06

    The dark-field image obtained in grating-based x-ray phase-contrast imaging can provide information about the objects' microstructures on a scale smaller than the pixel size even with low geometric magnification. In this publication we demonstrate that the dark-field image quality can be enhanced with an energy-resolving pixel detector. Energy-resolved x-ray dark-field images were acquired with a 16-energy-channel photon-counting pixel detector with a 1 mm thick CdTe sensor in a Talbot-Lau x-ray interferometer. A method for contrast-noise-ratio (CNR) enhancement is proposed and validated experimentally. In measurements, a CNR improvement by a factor of 1.14 was obtained. This is equivalent to a possible radiation dose reduction of 23%.

  15. Single atom identification by energy dispersive x-ray spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lovejoy, T. C.; Dellby, N.; Krivanek, O. L. [Nion, 1102 8th St., Kirkland, Washington 98033 (United States); Ramasse, Q. M. [SuperSTEM Laboratory, STFC Daresbury, Keckwick Lane, Daresbury WA4 4AD (United Kingdom); Falke, M.; Kaeppel, A.; Terborg, R. [Bruker Nano GmbH, Schwarzschildstr. 12, 12489 Berlin (Germany); Zan, R. [School of Physics and Astronomy, University of Manchester, Manchester M13 9PL (United Kingdom)

    2012-04-09

    Using aberration-corrected scanning transmission electron microscope and energy dispersive x-ray spectroscopy, single, isolated impurity atoms of silicon and platinum in monolayer and multilayer graphene are identified. Simultaneously acquired electron energy loss spectra confirm the elemental identification. Contamination difficulties are overcome by employing near-UHV sample conditions. Signal intensities agree within a factor of two with standardless estimates.

  16. Production of Entangled X-Ray Photon Pairs by High Energy Electrons

    OpenAIRE

    Ispirian, K. A.; Ispiryan, M. K.

    2009-01-01

    Without developing a correct theory, the rate of the production of entangled photon pairs in the X-ray region by high energy electrons is estimated for experimental parameters used in a few experiments on X-ray parametric down conversion. Taking into account the need for X-ray entangled X-ray photons, it is proposed to begin the experimental study of such mechanism of nonlinear X-ray optics before the launch of the X-ray free electron lasers.

  17. Scanning electron microscopy-energy dispersive X-ray spectrometer ...

    African Journals Online (AJOL)

    The distribution of arsenic (As) and cadmium (Cd) in himematsutake was analyzed using scanning electron microscopy-energy dispersive X-ray spectrometer (SEM-EDX). The atomic percentage of the metals was confirmed by inductively coupled plasma-mass spectrometer (ICP-MS). Results show that the accumulation of ...

  18. Research Note: Energy dispersive x-ray fluorescence analysis ...

    African Journals Online (AJOL)

    Energy Dispersive X-Ray fluorescence (EDXRF) technique for the analysis of geological, biological and environmental samples is described. The technique has been applied in the analysis of 10 (geological, biological, environmental) standard reference materials. The accuracy and precision of the technique were attested ...

  19. Energy dispersive X-Ray fluorescence spectrometric study of ...

    African Journals Online (AJOL)

    , Ca, Mn, Ti, Cu, Mo, Fe, Zn, Ni, Re, Eu and Pb using Energy Dispersive X-ray fluorescence (ED-XRF) spectrometry, following standard procedures. The results showed varying amounts of the studied elements in the samples from the two ...

  20. Simultaneous dual-energy X-ray stereo imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mokso, Rajmund, E-mail: rajmund.mokso@psi.ch [Paul Scherrer Institute, Swiss Light Source, CH 5232 Villigen (Switzerland); Oberta, Peter [Institute of Physics of the Academy of Sciences of the Czech Republic, v.v.i., Na Slovance 1999/2, Praha 8 (Czech Republic); Rigaku Innovative Technologies Europe s.r.o., Novodvorska 994, Praha 4 (Czech Republic)

    2015-06-26

    A Laue–Bragg geometry is introduced for splitting an X-ray beam and tuning each of the two branches to selected wavelength. Stereoscopic and dual-energy imaging was performed with this system. Dual-energy or K-edge imaging is used to enhance contrast between two or more materials in an object and is routinely realised by acquiring two separate X-ray images each at different X-ray wavelength. On a broadband synchrotron source an imaging system to acquire the two images simultaneously was realised. The single-shot approach allows dual-energy and stereo imaging to be applied to dynamic systems. Using a Laue–Bragg crystal splitting scheme, the X-ray beam was split into two and the two beam branches could be easily tuned to either the same or to two different wavelengths. Due to the crystals’ mutual position, the two beam branches intercept each other under a non-zero angle and create a stereoscopic setup.

  1. The color of X-rays Spectral X-ray computed tomography using energy sensitive pixel detectors

    CERN Document Server

    Schioppa, Enrico Junior

    Energy sensitive X-ray imaging detectors are produced by connecting a semiconductor sensor to a spectroscopic pixel readout chip. In this thesis, the applicability of such detectors to X-ray Computed Tomography (CT) is studied. A prototype Medipix based silicon detector is calibrated using X-ray fluorescence. The charge transport properties of the sensor are characterized using a high energy beam of charged particles at the Super Proton Synchrotron (SPS) at the European Center for Nuclear Research (CERN). Monochromatic X-rays at the European Synchrotron Radiation Facility (ESRF) are used to determined the energy response function. These data are used to implement a physics-based CT projection operator that accounts for the transmission of the source spectrum through the sample and detector effects. Based on this projection operator, an iterative spectral CT reconstruction algorithm is developed by extending an Ordered Subset Expectation Maximization (OSEM) method. Subsequently, a maximum likelihood based algo...

  2. High-energy X-ray spectra of five sources.

    Science.gov (United States)

    Ricker, G. R.; Mcclintock, J. E.; Gerassimenko, M.; Lewin , W. H. G.

    1973-01-01

    On October 15-16, 1970, we carried out balloon X-ray observations from Australia at energies above 15 keV. We present the high-energy X-ray spectra of three sources discovered by us, GX 301-2, GX 304-1, and GX 1 + 4. The data suggest that these high-energy sources correspond to the sources 2U 1223-62, 2U 1258-61, and 2U 1728-24 respectively. We also present the spectra for two additional sources, GX 5-1 (2U 1757-25) and GX 3 + 1 (2U 1744-26). The average intensity of the highly variable source GX 301-2 was observed to be as great as Tau X-1 in the energy range 15-50 keV.

  3. Attenuation of high-energy x rays by iron shielding

    Energy Technology Data Exchange (ETDEWEB)

    Bespalov, V.I.; Chakhlov, V.L.; Shtein, M.M.

    1988-04-01

    Monte Carlo calculations are presented on electron-accelerator x-ray spectra for actual target thicknesses and electron energies of 4-50 MeV. Effective attenuation coefficients have been obtained as well as build-up factors for collimated beams andiron shielding of thickness form 1 to 80 cm. The radiation contrast has been determined as a function of thickness for this energy range.

  4. Phase contrast imaging with coherent high energy X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Snigireva, I. [ESRF, Grenoble (France)

    1997-02-01

    X-ray imaging concern high energy domain (>6 keV) like a contact radiography, projection microscopy and tomography is used for many years to discern the features of the internal structure non destructively in material science, medicine and biology. In so doing the main contrast formation is absorption that makes some limitations for imaging of the light density materials and what is more the resolution of these techniques is not better than 10-100 {mu}m. It was turned out that there is now way in which to overcome 1{mu}m or even sub-{mu}m resolution limit except phase contrast imaging. It is well known in optics that the phase contrast is realised when interference between reference wave front and transmitted through the sample take place. Examples of this imaging are: phase contrast microscopy suggested by Zernike and Gabor (in-line) holography. Both of this techniques: phase contrast x-ray microscopy and holography are successfully progressing now in soft x-ray region. For imaging in the hard X-rays to enhance the contrast and to be able to resolve phase variations across the beam the high degree of the time and more importantly spatial coherence is needed. Because of this it was reasonable that the perfect crystal optics was involved like Bonse-Hart interferometry, double-crystal and even triple-crystal set-up using Laue and Bragg geometry with asymmetrically cut crystals.

  5. Plasma instability control toward high fluence, high energy x-ray continuum source

    Science.gov (United States)

    Poole, Patrick; Kirkwood, Robert; Wilks, Scott; Blue, Brent

    2017-10-01

    X-ray source development at Omega and NIF seeks to produce powerful radiation with high conversion efficiency for material effects studies in extreme fluence environments. While current K-shell emission sources can achieve tens of kJ on NIF up to 22 keV, the conversion efficiency drops rapidly for higher Z K-alpha energies. Pulsed power devices are efficient generators of MeV bremsstrahlung x-rays but are unable to produce lower energy photons in isolation, and so a capability gap exists for high fluence x-rays in the 30 - 100 keV range. A continuum source under development utilizes instabilities like Stimulated Raman Scattering (SRS) to generate plasma waves that accelerate electrons into high-Z converter walls. Optimizing instabilities using existing knowledge on their elimination will allow sufficiently hot and high yield electron distributions to create a superior bremsstrahlung x-ray source. An Omega experiment has been performed to investigate the optimization of SRS and high energy x-rays using Au hohlraums with parylene inner lining and foam fills, producing 10× greater x-ray yield at 50 keV than conventional direct drive experiments on the facility. Experiment and simulation details on this campaign will be presented. This work was performed under the auspices of the US DoE by LLNL under Contract No. DE-AC52-07NA27344.

  6. Spectacular X-ray Jet Points Toward Cosmic Energy Booster

    Science.gov (United States)

    2000-06-01

    NASA's Chandra X-ray Observatory has revealed a spectacular luminous spike of X rays that emanates from the vicinity of a giant black hole in the center of the radio galaxy Pictor A. The spike, or jet, is due to a beam of particles that streaks across hundreds of thousands of light years of intergalactic space toward a brilliant X-ray hot spot that marks its end point. Pictor A Image Press Image and Caption The hot spot is at least 800 thousand light years (8 times the diameter of our Milky Way galaxy) away from where the jet originates. It is thought to represent the advancing head of the jet, which brightens conspicuously where it plows into the tenuous gas of intergalactic space. The jet, powered by the giant black hole, originates from a region of space no bigger than the solar system. "Both the brightness and the spectrum of the X rays are very different from what theory predicts," Professor Andrew Wilson reported today at the 196th national meeting of the American Astronomical Society in Rochester, New York. Wilson, of the University of Maryland, College Park, along with Dr. Patrick Shopbell and Dr. Andrew Young, also of the University of Maryland, are submitting an article on this research to the Astrophysical Journal. "The Chandra observations are telling us that something out there is producing many more high-energy particles than we expected," said Wilson. One possible explanation for the X rays is that shock waves along the side and head of the X-ray jet are accelerating electrons and possibly protons to speeds close to that of light. In the process the electrons are boosted to energies as high as 100 million times their own rest mass energy. These electrons lose their energy rapidly as they produce X rays, so this could be the first direct evidence of this process so far outside a galaxy. The hot spot has been seen with optical and radio telescopes. Radio telescopes have also observed a faint jet. Jets are thought to be produced by the extreme

  7. Luminescence imaging of water during irradiation of X-ray photons lower energy than Cerenkov- light threshold

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Seiichi; Koyama, Shuji; Komori, Masataka [Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine (Japan); Toshito, Toshiyuki [Department of Proton Therapy Physics, Nagoya Proton Therapy Center, Nagoya City West Medical Center (Japan)

    2016-10-01

    Luminescence imaging of water using X-ray photon irradiation at energy lower than maximum energy of ~200 keV is thought to be impossible because the secondary electrons produced in this energy range do not emit Cerenkov- light. Contrary to this consensus assumption, we show that the luminescence imaging of water can be achieved by X-ray irradiation at energy lower than 120 keV. We placed water phantoms on a table with a conventional X-ray imaging system, and luminescence images of these phantoms were measured with a high-sensitivity, cooled charge coupled device (CCD) camera during X-ray photon irradiation at energy below 120 keV. We also carried out such imaging of an acrylic block and plastic scintillator. The luminescence images of water phantoms taken during X-ray photon irradiation clearly showed X-ray photon distribution. The intensity of the X-ray photon images of the phantom increased almost proportionally to the number of X-ray irradiations. Lower-energy X-ray photon irradiation showed lower-intensity luminescence at the deeper parts of the phantom due to the higher X-ray absorption in the water phantom. Furthermore, lower-intensity luminescence also appeared at the deeper parts of the acrylic phantom due to its higher density than water. The intensity of the luminescence for water was 0.005% of that for plastic scintillator. Luminescence imaging of water during X-ray photon irradiation at energy lower than 120 keV was possible. This luminescence imaging method is promising for dose estimation in X-ray imaging systems.

  8. Studies of dark energy with X-ray observatories.

    Science.gov (United States)

    Vikhlinin, Alexey

    2010-04-20

    I review the contribution of Chandra X-ray Observatory to studies of dark energy. There are two broad classes of observable effects of dark energy: evolution of the expansion rate of the Universe, and slow down in the rate of growth of cosmic structures. Chandra has detected and measured both of these effects through observations of galaxy clusters. A combination of the Chandra results with other cosmological datasets leads to 5% constraints on the dark energy equation-of-state parameter, and limits possible deviations of gravity on large scales from general relativity.

  9. Low-energy X-ray detection with an in-vacuum PILATUS detector

    Science.gov (United States)

    Marchal, Julien; Luethi, Benjamin; Ursachi, Catalin; Mykhaylyk, Vitaliy; Wagner, Armin

    2011-11-01

    The feasibility of using PILATUS single-X-ray-photon counting detectors for long-wavelength macromolecular crystallography was investigated by carrying out a series of experiments at Diamond Light Source. A water-cooled PILATUS 100k detector was tested in vacuum with monochromatic 3 keV X-rays on the Diamond test beamline B16. Effects of detector cooling on noise performance, energy calibration and threshold trimming were investigated. When detecting 3 keV X-rays, the electronic noise of the analogue output of pixel preamplifiers forces the threshold to be set at a higher level than the 50% energy level recommended to minimize charge-sharing effects. The influence of threshold settings at low X-ray energy was studied by characterizing the detector response to a collimated beam of 3 keV X-rays scanned across several pixels. The relationship between maximum count rate and minimum energy threshold was investigated separately for various detector gain settings.

  10. Application of X-ray Optics to Energy-Dispersive Spectroscopy.

    Science.gov (United States)

    McCarthy; McMillan

    1998-11-01

    : X-ray optics have been used in X-ray analytical instruments for several years. Applications of X-ray optics have been reported in X-ray diffraction, X-ray fluorescence, and wavelength dispersive spectroscopy. X-ray optics have been used to increase the X-ray flux incident on the sample or to direct and focus emitted X-rays from a sample. We report here the use of a grazing incidence optic (GIO) as a flux-enhancing collimator for use with an energy-dispersive (ED) detector used to perform electron beam microanalysis. We found that the GIO in combination with an ED spectrometer (EDS) provides substantial intensity gain for X-ray lines with energy below 1 keV. The GIO is also found to provide a modest focus effect, and introduces minimal spectral artifacts.

  11. Low-energy shelf response in thin energy-dispersive X-ray detectors from Compton scattering of hard X-rays

    Science.gov (United States)

    Michel-Hart, N.; Elam, W. T.

    2017-08-01

    Silicon drift detectors have been successfully employed in both soft and hard X-ray spectroscopy. The response function to incident radiation at soft X-ray levels has been well studied and modeled, but less research has been published on response functions for these detectors to hard X-ray input spectra above 20 keV. When used with hard X-ray sources a significant low energy, non-peak response exists which can adversely affect detection limits for lighter elements in, for example, X-ray fluorescence spectroscopy. We present a numerical model that explains the non-peak response function of silicon drift detectors to hard X-rays based on incoherent Compton scattering within the detector volume. Experimental results are presented and numerically compared to model results.

  12. An overview of quantification methods in energy-dispersive X-ray ...

    Indian Academy of Sciences (India)

    Keywords. X-ray fluorescence; X-ray spectrometry; quantitative XRF analysis; in situ XRF measurements. Abstract. This paper reviews the major factors influencing the accuracy of the energy-dispersive X-ray fluorescence (EDXRF) analysis including physical and chemical matrix effects (resulting from particle size, surface ...

  13. High-resolution x-ray studies of an AXAF high-energy transmission grating

    DEFF Research Database (Denmark)

    Abdali, S.; Christensen, Finn Erland; Schnopper, H. W.

    1993-01-01

    A triple axis X-ray diffractometer, designed and built at the Danish Space Research Institute, was used to make a high resolution study of the performance of a 2000 angstroms period, high energy X-ray transmission grating developed at MIT for one of the grating spectrometers on the Advanced X-ray...

  14. High-Energy X-Ray Diffraction Analysis Tool

    Energy Technology Data Exchange (ETDEWEB)

    2011-11-29

    The functionality of heRXD includes the following: distance and angular calibration and viewing flat-panel detector images used for X-ray diffraction; image (polar) rebinning or "caking"; line position fitting in powder diffraction images; image segmentation or "blob finding"; crystal orentation indesing; and lattice vector refinement. These functionalities encompass a critical set analyzing teh data for high-energy diffraction measurements that are currently performed at synchrotron sources such as the Advanced Photon Source (APS). The software design modular and open source under LGPL. The intent is to provide a common framework and graphical user interface that has the ability to utillize internal as well as external subroutines to provide various optins for performing the fuctionalities listed above. The software will initially be deployed at several national user facilities--including APS, ALS, and CHESS--and then made available for download using a hosting service such as sourceforge.

  15. Study of osteoporosis using dual energy X-ray absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Someya, Misao (Showa Univ., Tokyo (Japan). School of Medicine)

    1992-04-01

    Dual energy X-ray absorptiometry (Hologic QDR-1000) was used to quantitatively analyze the diagnosis and prevention of osteoporosis. The peak bone mineral density (BMD) of the spine appeared in normal men in their twenties and in normal women in their thirties. There was acceleration of bone loss in the 50 to 60 year age bracket (premenopause and postmenopause) in normal women. On the contrary, the peak BMD of the femoral neck in normal men and women appeared in their twenties after which it decreased slightly with age. Comparison showed that the femoral neck BMD of normal women was lower than that of men throughout all ages. The fracture threshold, 0.756 g/cm[sup 2] for the spine, was obtained by scanning 73 females with spinal fractures, the mean BMDs for L2-L4 at the 90th percentile level were used as the fracture threshold. The fracture threshold of femoral neck fracture was the femoral proximal BMD of the 9th decile. Classification by the Public Welfare Silver Science Group's method and by the Singh index, except Grades I, II, and III, revealed a difference; as the severity of bone atrophy advanced, BMD tended to decrease. The percent reduction of MBD 10 years after premenopause was 21.0% in the spine and 13.2% in the femoral neck. Correlation between BMD and weight, weight/height ratio, BODY MASS INDEX was significant. No correlation between BMD and bone metabolism factors in the blood was found in 50 osteoporotic patients. The results of this study showed that dual energy X-ray absorptiometry (Hologic QDR-1000) can objectively diagnose and suggest measures for prevention of osteoporosis, and is clinically useful. (author).

  16. A new X-ray pinhole camera for energy dispersive X-ray fluorescence imaging with high-energy and high-spatial resolution

    Energy Technology Data Exchange (ETDEWEB)

    Romano, F.P., E-mail: romanop@lns.infn.it [IBAM, CNR, Via Biblioteca 4, 95124 Catania (Italy); INFN-LNS, Via S. Sofia 62, 95123 Catania (Italy); Altana, C. [INFN-LNS, Via S. Sofia 62, 95123 Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Via S. Sofia 64, 95123 Catania (Italy); Cosentino, L.; Celona, L.; Gammino, S.; Mascali, D. [INFN-LNS, Via S. Sofia 62, 95123 Catania (Italy); Pappalardo, L. [IBAM, CNR, Via Biblioteca 4, 95124 Catania (Italy); INFN-LNS, Via S. Sofia 62, 95123 Catania (Italy); Rizzo, F. [INFN-LNS, Via S. Sofia 62, 95123 Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Via S. Sofia 64, 95123 Catania (Italy)

    2013-08-01

    A new X-ray pinhole camera for the Energy Dispersive X-ray Fluorescence (ED-XRF) imaging of materials with high-energy and high-spatial resolution, was designed and developed. It consists of a back-illuminated and deep depleted CCD detector (composed of 1024 × 1024 pixels with a lateral size of 13 μm) coupled to a 70 μm laser-drilled pinhole-collimator, positioned between the sample under analysis and the CCD. The X-ray pinhole camera works in a coaxial geometry allowing a wide range of magnification values. The characteristic X-ray fluorescence is induced on the samples by irradiation with an external X-ray tube working at a maximum power of 100 W (50 kV and 2 mA operating conditions). The spectroscopic capabilities of the X-ray pinhole camera were accurately investigated. Energy response and energy calibration of the CCD detector were determined by irradiating pure target-materials emitting characteristic X-rays in the energy working-domain of the system (between 3 keV and 30 keV). Measurements were performed by using a multi-frame acquisition in single-photon counting. The characteristic X-ray spectra were obtained by an automated processing of the acquired images. The energy resolution measured at the Fe–Kα line is 157 eV. The use of the X-ray pinhole camera for the 2D resolved elemental analysis was investigated by using reference-patterns of different materials and geometries. The possibility of the elemental mapping of samples up to an area of 3 × 3 cm{sup 2} was demonstrated. Finally, the spatial resolution of the pinhole camera was measured by analyzing the profile function of a sharp-edge. The spatial resolution determined at the magnification values of 3.2 × and 0.8 × (used as testing values) is about 90 μm and 190 μm respectively. - Highlights: • We developed an X-ray pinhole camera for the 2D X-ray fluorescence imaging. • X-ray spectra are obtained by a multi-frame acquisition in single photon mode. • The energy resolution in the X-ray

  17. X-ray optics high-energy-resolution applications

    CERN Document Server

    Shvyd’ko, Yuri

    2004-01-01

    The generation of radiation with well-defined frequency and wavelength, and the ability to precisely determine these quantities, are of fundamental importance in physics and other natural sciences Monochromatic radiation enables both very accurate structure determinations and studies of the dynamics of living and non-living matter It is crucial for the realization of standards of time and length, for the determination of fundamental constants, and for many other aspects of basic research Bragg backscattering from perfect crystals is a tool for creating, manipulating, and analyzing x-rays with highest spectral purity It has the unique feature of selecting x-rays with narrow spectral bandwidth This book describes the theoretical foundations and principles of x-ray crystal optics with high spectral resolution Various experimental studies and applications are presented and the author also addresses the development of instrumentation, such as high-resolution x-ray monochromators, analyzers, wavelength meters, reso...

  18. Quality in dual-energy X-ray absorptiometry scans.

    Science.gov (United States)

    Morgan, Sarah L; Prater, Ginnie L

    2017-11-01

    Dual-energy X-ray absorptiometry (DXA) is the gold standard for measuring bone mineral density (BMD), making the diagnosis of osteoporosis, and for monitoring changes in BMD over time. DXA data are also used in the determination of fracture risk. Procedural steps in DXA scanning can be broken down into scan acquisition, analysis, interpretation, and reporting. Careful attention to quality control pertaining to these procedural steps should theoretically be beneficial in patient management. Inattention to procedural steps and errors that may occur at each step has the possibility of providing information that would inform inappropriate clinical decisions, generating unnecessary healthcare expenses and ultimately causing avoidable harm to patients. This article reviews errors in DXA scanning that affect trueness and precision related to the machine, the patient, and the technologist and reviews articles which document problems with DXA quality in clinical and research settings. An understanding of DXA errors is critical for DXA quality; programs such as certification of DXA technologists and interpreters help in assuring quality bone densitometry. As DXA errors are common, pay for performance requiring DXA technologists and interpreters to be certified and follow quality indicators is indicated. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Development of a dual MCP framing camera for high energy x-rays.

    Science.gov (United States)

    Izumi, N; Hall, G N; Carpenter, A C; Allen, F V; Cruz, J G; Felker, B; Hargrove, D; Holder, J; Kilkenny, J D; Lumbard, A; Montesanti, R; Palmer, N E; Piston, K; Stone, G; Thao, M; Vern, R; Zacharias, R; Landen, O L; Tommasini, R; Bradley, D K; Bell, P M

    2014-11-01

    Recently developed diagnostic techniques at LLNL require recording backlit images of extremely dense imploded plasmas using hard x-rays, and demand the detector to be sensitive to photons with energies higher than 50 keV [R. Tommasini et al., Phys. Phys. Plasmas 18, 056309 (2011); G. N. Hall et al., "AXIS: An instrument for imaging Compton radiographs using ARC on the NIF," Rev. Sci. Instrum. (these proceedings)]. To increase the sensitivity in the high energy region, we propose to use a combination of two MCPs. The first MCP is operated in a low gain regime and works as a thick photocathode, and the second MCP works as a high gain electron multiplier. We tested the concept of this dual MCP configuration and succeeded in obtaining a detective quantum efficiency of 4.5% for 59 keV x-rays, 3 times larger than with a single plate of the thickness typically used in NIF framing cameras.

  20. Energy dispersive X-ray analysis in the electron microscope

    CERN Document Server

    Bell, DC

    2003-01-01

    This book provides an in-depth description of x-ray microanalysis in the electron microscope. It is sufficiently detailed to ensure that novices will understand the nuances of high-quality EDX analysis. Includes information about hardware design as well as the physics of x-ray generation, absorption and detection, and most post-detection data processing. Details on electron optics and electron probe formation allow the novice to make sensible adjustments to the electron microscope in order to set up a system which optimises analysis. It also helps the reader determine which microanalytical me

  1. [Digital fluoroscopy imaging system with dual energy X-ray image decomposition].

    Science.gov (United States)

    Zhang, Feng; Chen, Zhencheng; Deng, Zhensheng; Jiang, Dazong

    2004-04-01

    Dual-kilovolt technique was realized in dual energy X-ray imaging system with computer controlled KV adjustment, filter switching and image acquirement. The dual energy images can be obtained in 2-3 seconds to avoid moving artifact. Low energy photons in high energy X-ray beam can be attenuated effectively by a 2 mm Cu filter to separate the spectra of the high and low energy X-rays. A simplified dual energy decomposition method was used to obtain the soft tissue image. An example of chest dual energy radiographs is presented to illustrate the performance of the system.

  2. Total reflection X-ray fluorescence and energy-dispersive X-ray ...

    Indian Academy of Sciences (India)

    Nuclear energy is one of the clean options of electricity generation for the betterment of human life. India has an ambitious program for such electricity generation using different types of nuclear reactors. The safe and efficient generation of electricity from these reactors requires quality control of different nuclear materials, ...

  3. Characterization of breast calcification types using dual energy x-ray method

    Science.gov (United States)

    Martini, N.; Koukou, V.; Fountos, G.; Michail, C.; Bakas, A.; Kandarakis, I.; Speller, R.; Nikiforidis, G.

    2017-10-01

    Calcifications are products of mineralization whose presence is usually associated with pathological conditions. The minerals mostly seen in several diseases are calcium oxalate (CaC2O4), calcium carbonate (CaCO3) and hydroxyapatite (HAp). Up to date, there is no in vivo method that could discriminate between minerals. To this aim, a dual energy x-ray method was developed in the present study. An analytical model was implemented for the determination of the Calcium/Phosphorus mass ratio ({{{m}Ca}}/{{{m}P}} ). The simulation was carried out using monoenergetic and polyenergetic x-rays and various calcification thicknesses (100-1000 μ m ) and types (CaC2O4, CaCO3, HAp). The experimental evaluation of the method was performed using the optimized irradiation conditions obtained from the simulation study. X-ray tubes, combined with energy dispersive and energy integrating (imaging) detectors, were used for the determination of the {{{m}Ca}}/{{{m}P}} in phantoms of different mineral types and thicknesses. Based on the results of the experimental procedure, statistical significant difference was observed between the different types of minerals when calcification thicknesses were 300 μ m or higher.

  4. Interferometric X-Ray Imaging of Breast Cancer Specimens at 51 keV X-Ray Energy

    Science.gov (United States)

    Takeda, Tohoru; Wu, Jin; Tsuchiya, Yoshinori; Yoneyama, Akio; Lwin, Thet Thet; Aiyoshi, Yuji; Zeniya, Tsutomu; Hyodo, Kazuyuki; Ueno, Ei

    2004-08-01

    The feasibility of the interferometric X-ray imaging technique is examined for revealing the features of breast cancer specimens. The interferometric X-ray imaging system consisted of an asymmetrically cut silicon crystal, a monolithic X-ray interferometer, a phase-shifter, an object cell, and an X-ray CCD camera. Ten 10-mm-thick formalin-fixed breast cancer specimens were imaged at 51 keV, and these images were compared with absorption-contrast X-ray images obtained at 18 keV monochromatic synchrotron X-ray. The interferometric X-ray images clearly depicted the essential features of the breast cancer such as microcalcification down to a size of 0.036 mm, spiculation, and detailed inner soft tissue structures closely matched with histopathological morphology, while the absorption-contrast X-ray images obtained using nearly the same X-ray dose only resolved microcalcification down to a size of 0.108 mm and spiculation. The interferometric X-ray imaging technique can be considered to be an innovative technique for the early and accurate diagnosis of breast cancer using an extremely low X-ray dose.

  5. Preliminary Research on Dual-Energy X-Ray Phase-Contrast Imaging

    OpenAIRE

    Han, Huajie; Wang, Shenghao; Gao, Kun; Wang, Zhili; Zhang, Can; Yang, Meng; Zhang, Kai; Zhu, Peiping

    2015-01-01

    Dual-energy X-ray absorptiometry (DEXA) has been widely applied to measure bone mineral density (BMD) and soft-tissue composition of human body. However, the use of DEXA is greatly limited for low-Z materials such as soft tissues due to their weak absorption. While X-ray phase-contrast imaging (XPCI) shows significantly improved contrast in comparison with the conventional standard absorption-based X-ray imaging for soft tissues. In this paper, we propose a novel X-ray phase-contrast method t...

  6. Energy response of graphite-mixed magnesium borate TLDs to low energy x-rays

    DEFF Research Database (Denmark)

    Pelliccioni, M.; Prokic, M.; Esposito, A.

    1991-01-01

    of the energy response to very low energy x-rays are presented and evidence of agreement between experimental and calculated conversion coefficient H'(0.07, alpha = 0-degrees)/Ka is also shown. A monochromatized x-ray beam from a synchrotron radiation source in the energy range from 3 to 12 keV has been......Graphite-mixed sintered magnesium borate TL dosemeters are attractive for beta/gamma dosimetry because they combine a low energy dependence to beta-rays with near tissue or air equivalence to photon irradiations and a high sensitivity. In this paper results from the experimental measurements...

  7. Quantitative energy-dispersive x-ray diffraction for identification of counterfeit medicines: a preliminary study

    Science.gov (United States)

    Crews, Chiaki C. E.; O'Flynn, Daniel; Sidebottom, Aiden; Speller, Robert D.

    2015-06-01

    The prevalence of counterfeit and substandard medicines has been growing rapidly over the past decade, and fast, nondestructive techniques for their detection are urgently needed to counter this trend. In this study, energy-dispersive X-ray diffraction (EDXRD) combined with chemometrics was assessed for its effectiveness in quantitative analysis of compressed powder mixtures. Although EDXRD produces lower-resolution diffraction patterns than angular-dispersive X-ray diffraction (ADXRD), it is of interest for this application as it carries the advantage of allowing the analysis of tablets within their packaging, due to the higher energy X-rays used. A series of caffeine, paracetamol and microcrystalline cellulose mixtures were prepared with compositions between 0 - 100 weight% in 20 weight% steps (22 samples in total, including a centroid mixture), and were pressed into tablets. EDXRD spectra were collected in triplicate, and a principal component analysis (PCA) separated these into their correct positions in the ternary mixture design. A partial least-squares (PLS) regression model calibrated using this training set was validated using both segmented cross-validation, and with a test set of six samples (mixtures in 8:1:1 and 5⅓:2⅓:2⅓ ratios) - the latter giving a root-mean square error of prediction (RMSEP) of 1.30, 2.25 and 2.03 weight% for caffeine, paracetamol and cellulose respectively. These initial results are promising, with RMSEP values on a par with those reported in the ADXRD literature.

  8. Portable energy-dispersive X-ray fluorescence equipment for the ...

    Indian Academy of Sciences (India)

    Abstract. Energy-dispersive X-ray fluorescence (EDXRF) especially in its portable version, gen- erally characterized by a small X-ray tube and a Si-PIN or Si-drift detector is particularly useful to analyse works of art. EDXRF technique is nondestructive, noninvasive and multielemental. A variety of works, such as paintings of ...

  9. High energy x-ray reflectivity and scattering study from spectrum-x-gamma flight mirrors

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Budtz-Jørgensen, Carl; Frederiksen, P. Kk

    1993-01-01

    Line radiation from Fe K-alpha(1), Cu K-alpha(1), and Ag K-alpha(1) is used to study the high energy X-ray reflectivity and scattering behavior of flight-quality X-ray mirrors having various Al substrates. When both the specular and the scattered radiation are integrated, near theoretical...

  10. The nuclear spectroscopic telescope array (NuSTAR) high-energy X-ray mission

    DEFF Research Database (Denmark)

    Madsen, Kristin K.; Harrison, Fiona A.; Hongjun An

    2014-01-01

    The Nuclear Spectroscopic Telescope Array (NuSTAR) mission was launched on 2012 June 13 and is the first focusing high-energy X-ray telescope in orbit operating above ~10 keV. NuSTAR flies two co-aligned Wolter-I conical approximation X-ray optics, coated with Pt/C and W/Si multilayers...

  11. Relative calibration of energy thresholds on multi-bin spectral x-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Sjölin, M., E-mail: martin.sjolin@mi.physics.kth.se; Danielsson, M.

    2016-12-21

    Accurate and reliable energy calibration of spectral x-ray detectors used in medical imaging is essential for avoiding ring artifacts in the reconstructed images (computed tomography) and for performing accurate material basis decomposition. A simple and accurate method for relative calibration of the energy thresholds on a multi-bin spectral x-ray detector is presented. The method obtains the linear relations between all energy thresholds in a channel by scanning the thresholds with respect to each other during x-ray illumination. The method does not rely on a model of the detector's response function and does not require any identifiable features in the x-ray spectrum. Applying the same method, the offset between the thresholds can be determined also without external stimuli by utilizing the electronic noise as a source. The simplicity and accuracy of the method makes it suitable for implementation in clinical multi-bin spectral x-ray imaging systems.

  12. Low-Energy Microfocus X-Ray Source for Enhanced Testing Capability in the Stray Light Facility

    Science.gov (United States)

    Gaskin, Jessica; O'Dell, Stephen; Kolodziejczak, Jeff

    2015-01-01

    Research toward high-resolution, soft x-ray optics (mirrors and gratings) necessary for the next generation large x-ray observatories requires x-ray testing using a low-energy x-ray source with fine angular size (energy microfocus (approximately 0.1 mm spot) x-ray source from TruFocus Corporation that mates directly to the Stray Light Facility (SLF). MSFC X-ray Astronomy team members are internationally recognized for their expertise in the development, fabrication, and testing of grazing-incidence optics for x-ray telescopes. One of the key MSFC facilities for testing novel x-ray instrumentation is the SLF. This facility is an approximately 100-m-long beam line equipped with multiple x-ray sources and detectors. This new source adds to the already robust compliment of instrumentation, allowing MSFC to support additional internal and community x-ray testing needs.

  13. Energy dispersive detector for white beam synchrotron x-ray fluorescence imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Matthew D., E-mail: Matt.Wilson@stfc.ac.uk; Seller, Paul; Veale, Matthew C. [Science and Technology Facilities Council, Rutherford Appleton Laboratory, Harwell Campus,UK (United Kingdom); Connolley, Thomas [Diamond Light Source, I12 Beamline, Harwell Campus, Didcot, Oxfordshire (United Kingdom); Dolbnya, Igor P.; Malandain, Andrew; Sawhney, Kawal [Diamond Light Source, B16 Beamline, Harwell Campus, Didcot, Oxfordshire (United Kingdom); Grant, Patrick S.; Liotti, Enzo; Lui, Andrew [Department of Materials, University of Oxford Parks Road, Oxford (United Kingdom)

    2016-07-27

    A novel, “single-shot” fluorescence imaging technique has been demonstrated on the B16 beamline at the Diamond Light Source synchrotron using the HEXITEC energy dispersive imaging detector. A custom made furnace with 200µm thick metal alloy samples was positioned in a white X-ray beam with a hole made in the furnace walls to allow the transmitted beam to be imaged with a conventional X-ray imaging camera consisting of a 500 µm thick single crystal LYSO scintillator, mirror and lens coupled to an AVT Manta G125B CCD sensor. The samples were positioned 45° to the incident beam to enable simultaneous transmission and fluorescence imaging. The HEXITEC detector was positioned at 90° to the sample with a 50 µm pinhole 13 cm from the sample and the detector positioned 2.3m from pinhole. The geometric magnification provided a field of view of 1.1×1.1mm{sup 2} with one of the 80×80 pixels imaging an area equivalent to 13µm{sup 2}. Al-Cu alloys doped with Zr, Ag and Mo were imaged in transmission and fluorescence mode. The fluorescence images showed that the dopant metals could be simultaneously imaged with sufficient counts on all 80x80 pixels within 60 s, with the X-ray flux limiting the fluorescence imaging rate. This technique demonstrated that it is possible to simultaneously image and identify multiple elements on a spatial resolution scale ~10µm or higher without the time consuming need to scan monochromatic energies or raster scan a focused beam of X-rays. Moving to high flux beamlines and using an array of detectors could improve the imaging speed of the technique with element specific imaging estimated to be on a 1 s timescale.

  14. Flash X-Ray Generator At High Energy: GREC

    Science.gov (United States)

    Buchet, J.; Biero, H.; Fourrier, G.

    1983-08-01

    GREC, an acronym for "Generateur de Radiographie EClair" was designed for visualisation, measurements and studies on dynamic behavior of materials under high explosive loading. GREC was built in 1974 by Physics International for the CEA. Since the first operating time, 1975, this facility has been improving, taking advantage of progress in the techniques involved, especialy focusing and transport of intense electron beams. In this paper, we describe the X-ray machine and give some details on the image detection device. The pulse generator, a 80 stages Marx Generator can deliver a peak voltage of 9 MV in 1.2/us by series erection of 2 x 80 capacitors charged at + 60 kV. The Hulse-forming network, a tri-axial Blumlein, delivers a 80 ns-pulse via a 26 ohms impedance transmission line to the transport section. This transport section is a 24 cm diameter, 2 meters long, magnetic-insulated coaxial line. At the end, the X-ray radiation is emitted by bremstrahlung of the electrons impinging the tantalum anode of the dis-charge diode. The main specifications are : - electrical : 7 -MV - 180 kA - 30 ns - X-ray : Diode 1 : 400 R at 1 meter ; spot size : 20 mm Diode 2 : 100 - 300 R at 1 meter ; spot size : 4-8 mm The image acouisition device has been designed for X-raying of objects under loading of un to 50 kg of high explosives. In the paper, we give some details on the exnerimental arrangement used. Despite the severe environmental shock constraints, reasonable measurements of line-integrated density are possible.

  15. Resonant inelastic scattering at intermediate X-ray energies

    CERN Document Server

    Hague, C F; Journel, L; Gallet, J J; Rogalev, A; Krill, G; Kappler, J P

    2000-01-01

    We describe resonant inelastic X-ray scattering (RIXS) experiments and magnetic circular dichroism (MCD) in X-ray fluorescence performed in the 3-5 keV range. The examples chosen are X-ray fluorescence MCD of FeRh and RIXS experiments performed at the L/sub 3/ edge of Ce. Fe Rh is antiferromagnetic at room temperature but has a transition to the ferromagnetic state above 400 K. The Rh MCD signal is compared with an augmented spherical wave calculation. The experiment confirms the predicted spin polarization of the Rh 4d valence states. The RIXS measurements on Ce compounds and intermetallics address the problem of mixed valency especially in systems where degeneracy with the Fermi level remains small. Examples are taken from the 2p to (4f5d) /sup +1/ followed by 3d to 2p RIXS for a highly ionic compound CeF /sub 3/ and for almost gamma -like CeCuSi. (38 refs).

  16. On filtration for high-energy phase-contrast x-ray imaging

    Science.gov (United States)

    Riess, Christian; Mohamed, Ashraf; Hinshaw, Waldo; Fahrig, Rebecca

    2015-03-01

    Phase-sensitive x-ray imaging promises unprecedented soft-tissue contrast and resolution. However, several practical challenges have to be overcome when using the setup in a clinical environment. The system design that is currently closest to clinical use is the grating-based Talbot-Lau interferometer (GBI).1-3 The requirements for patient imaging are low patient dose, fast imaging time, and high image quality. For GBI, these requirements can be met most successfully with a narrow energy width, high- ux spectrum. Additionally, to penetrate a human-sized object, the design energy of the system has to be well above 40 keV. To our knowledge, little research has been done so far to investigate optimal GBI filtration at such high x-ray energies. In this paper, we study different filtration strategies and their impact on high-energy GBI. Specifically, we compare copper filtration at low peak voltage with equal-absorption, equal-imaging time K-edge filtration of spectra with higher peak voltage under clinically realistic boundary conditions. We specifically focus on a design energy of 59 keV and investigate combinations of tube current, peak voltage, and filtration that lead to equal patient absorption. Theoretical considerations suggest that the K edge of tantalum might provide a transmission pocket at around 59 keV, yielding a well-shaped spectrum. Although one can observe a slight visibility benefit when using tungsten or tantalum filtration, experimental results indicate that visibility benefits most from a low x-ray tube peak voltage.

  17. Investigation of high-resolution superconducting tunnel junction detectors for low-energy X-ray fluorescence analysis

    CERN Document Server

    Beckhoff, B; Ulm, G

    2003-01-01

    The energy resolution of conventional semiconductor detectors is insufficient for simultaneously separating the leading fluorescence lines of low Z and medium Z materials in the soft X-ray regime. It is therefore important to investigate alternative detection instruments offering higher energy resolution and evaluate their applicability to soft X-ray fluorescence (XRF) analysis. In this paper, various results of the characterization and evaluation of a cryogenic superconducting tunnel junction (STJ) detector, which was provided to the Physikalisch-Technische Bundesanstalt (PTB) by the Lawrence Livermore National Laboratory, are given with respect to both detector response functions and XRF. For this investigation, monochromatized undulator radiation of high spectral purity, available to the PTB X-ray radiometry laboratory at the electron storage ring BESSY II, was employed, by which it was possible to record the STJ response functions at various photon energies of interest ranging from 180 to 1600 eV. By scan...

  18. Empirical studies of solar flares: Comparison of X-ray and H alpha filtergrams and analysis of the energy balance of the X-ray plasma

    Science.gov (United States)

    Moore, R. L.

    1979-01-01

    The physics of solar flares was investigated through a combined analysis of X-ray filtergrams of the high temperature coronal component of flares and H alpha filtergrams of the low temperature chromospheric component. The data were used to study the magnetic field configuration and its changes in solar flares, and to examine the chromospheric location and structure of X-ray bright points (XPB) and XPB flares. Each topic and the germane data are discussed. The energy balance of the thermal X-ray plasma in flares, while not studied, is addressed.

  19. Studies in K-shell X-ray energy shift for a 2p spectator vacancy

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, J.; Talukdar, B.; Laha, U.

    1989-10-01

    We examine a simple model for calculating X-ray energy shifts due to outer atomic vacancies and present some case studies. We find that this model is a good supplement for the traditional approach to the problem. (orig.).

  20. [X-ray hardening correction for ICT in testing workpiece].

    Science.gov (United States)

    Peng, Guang-han; Cai, Xin-hua; Han, Zhong; Yang, Xue-heng

    2008-06-01

    Since energy spectrum of X-ray is polychromatic source in X-ray industrial computerized tomography, the variation of attenuation coefficient with energy leads to the lower energy of X-ray radiation being absorbed preferentially when X-ray is transmitting the materials. And the higher the energy of X-ray, the lower the attenuation coefficient of X-ray. With the increase in the X-ray transmission thickness, it becomes easier for the X-ray to transmit the matter. Thus, the phenomenon of energy spectrum hardening of X-ray takes place, resulting from the interaction between X-ray and the materials. This results in false images in the reconstruction of X-ray industrial computerized tomography. Therefore, hardening correction of energy spectrum of X-ray has to be done. In the present paper, not only is the hardening phenomenon of X-ray transmitting the materials analyzed, but also the relation between the X-ray beam sum and the transmission thickness of X-ray is discussed. And according to the Beer law and the characteristics of interaction when X-ray is transmitting material, and by getting the data of X-ray beam sum, the relation equation is fitted between the X-ray beam sum and X-ray transmission thickness. Then, the relation and the method of equivalence are carried out for X-ray beam sum being corrected. Finally, the equivalent and monochromatic attenuation coefficient fitted value for X-ray transmitting the material is reasoned out. The attenuation coefficient fitted value is used for product back-projection image reconstruction in X-ray industrial computerized tomography. Thus, the effect caused by X-ray beam hardening is wiped off effectively in X-ray industrial computerized tomography.

  1. White Beam, X-Ray, Energy-Dispersive Diffractometry using Synchrotron Radiation

    DEFF Research Database (Denmark)

    Gerward, Leif; Buras, B.; Olsen, J. Staun

    1978-01-01

    The special features of left double quote white right double quote beam X-ray energy-dispersive diffractometry using synchrotron radiation are discussed on the basis of experiments performed at the Deutsches Electronen-Synchrotron, DESY.......The special features of left double quote white right double quote beam X-ray energy-dispersive diffractometry using synchrotron radiation are discussed on the basis of experiments performed at the Deutsches Electronen-Synchrotron, DESY....

  2. Certification of reference materials by energy-dispersive x-ray fluorescence spectrometry?

    DEFF Research Database (Denmark)

    Christensen, Leif Højslet; Heydorn, Kaj

    1985-01-01

    This paper studies the precision and accuracy that can be achieved using energy-dispersive x-ray fluorescence spectrometry for the determination of total sulphur content in BCR 38 Fly Ash issued by the European Community Bureau of Reference.......This paper studies the precision and accuracy that can be achieved using energy-dispersive x-ray fluorescence spectrometry for the determination of total sulphur content in BCR 38 Fly Ash issued by the European Community Bureau of Reference....

  3. Investigation of TLD-700 energy response to low energy x-ray encountered in diagnostic radiology

    Directory of Open Access Journals (Sweden)

    Herrati Ammar

    2016-01-01

    Full Text Available The aim of thiswork is to study the energy dependence of thermoluminescent dosimeter (TLD-700 for low energy X-ray beams encountered in conventional diagnostic radiology. In the first step, we studied some characteristics (reproducibility and linearity of TLD-700 chips using a 137Cs source, and selected TLD chips with reproducibility better than 2.5%. Then we determined TLD-700 energy response for diagnostic radiology X-ray qualities, and investigated its influence on air kerma estimate. A maximum deviation of 60% can be obtained if TLDs are calibrated for 137Cs radiation source and used in diagnostic radiology fields. However, this deviation became less than 20% if TLDs chips are calibrated for the reference x-ray radiation quality RQR5 (recommended by the IEC 61267 standard. Consequently, we recommend calibrating this kind of TLDdetector with RQR5 diagnostic radiology X-ray quality. This method permits to obtain a good accuracy when assessing the entrance dose in diagnostic radiology procedures.

  4. Determination of the effective energy in X-rays standard beams, mammography level

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Eduardo de Lima; Vivolo, Vitor; Potiens, Maria da Penha A., E-mail: Vivolo@ipen.b, E-mail: mppalbu@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The X-rays beams used in diagnostic radiology are heterogeneous. This means that, in a radiological beam, it can be found photons with different energies. Because of that is common to work with the concept of effective energy. In this study the effective energy of an X-rays system used in instruments calibration was determined, as part of the mammography radiation qualities establishment. The procedure presented here was developed based on information found in the literature. The X-ray mass attenuation coefficients for aluminum, given by NIST web site, were used and the mathematical adjusts were done using the Origin 8.0 program. The results are part of the mammographic X-rays beams characteristics determination and it is important to keep the quality of this reference system. (author)

  5. Fat to muscle ratio measurements with dual energy x-ray absorbtiometry

    Energy Technology Data Exchange (ETDEWEB)

    Chen, A. [Shenzhen College of International Education, 1st HuangGang Park St., Shenzhen, GuangDong (China); Luo, J. [Department of Biomedical Engineering, University at Buffalo, 332 Bonner Hall, Buffalo, NY 14260-1920 (United States); Wang, A. [Department of Computer Science, Carnegie Mellon University, Pittsburgh, PA 15213 (United States); Broadbent, C. [School of Engineering, Columbia University, 1130 Amsterdam Av., New York, NY 10027 (United States); Zhong, J. [Department of English, Dartmouth College, 6032 Sanborn House, Hanover, NH 03755 (United States); Dilmanian, F.A. [Departments of Radiation Oncology, Neurology, and Radiology, Stony Brook University, Stony Brook, NY 11794 (United States); Zafonte, F.; Zhong, Z. [National Synchrotron Light Source II, Brookhaven National Laboratory, Bldg. 743, Upton, NY 11973 (United States)

    2015-07-11

    Accurate measurement of the fat-to-muscle ratio in animal model is important for obesity research. An efficient way to measure the fat to muscle ratio in animal model using dual-energy absorptiometry is presented in this paper. A radioactive source exciting x-ray fluorescence from a target material is used to provide the two x-ray energies needed. The x-rays, after transmitting through the sample, are measured with an energy-sensitive Ge detector. Phantoms and specimens were measured. The results showed that the method was sensitive to the fat to muscle ratios with good linearity. A standard deviation of a few percent in the fat to muscle ratio could be observed with the x-ray dose of 0.001 mGy.

  6. Fat to Muscle Ratio Measurements with Dual Energy X Ray Absorbtiometry

    CERN Document Server

    Chen, A; Broadbent, C; Zhong, J; Dilmanian, A; Zafonte, F; Zhong, Z

    2014-01-01

    Accurate measurement of the fat-to-muscle ratio in animal model is important for obesity research. An efficient way to measure the fat to muscle ratio in animal model using dual-energy absorptiometry is presented in this paper. A radioactive source exciting x-ray fluorescence from a target material is used to provide the two x-ray energies needed. The x-rays, after transmitting through the sample, are measured with an energy-sensitive Ge detector. Phantoms and specimens were measured. The results showed that the method was sensitive to the fat to muscle ratios with good linearity. A standard deviation of a few percent in the fat to muscle ratio could be observed with the x-ray dose of 0.001 mGy.

  7. X-ray spectroscopy of energy materials under in situ/operando conditions

    Energy Technology Data Exchange (ETDEWEB)

    Crumlin, Ethan J., E-mail: ejcrumlin@lbl.gov [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Liu, Zhi [State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050 (China); School of Physical Science and Technology, ShanghaiTech University, Shanghai 200031 (China); Bluhm, Hendrik [Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Yang, Wanli; Guo, Jinghua [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Hussain, Zahid, E-mail: zhussain@lbl.gov [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2015-04-15

    A perspective and brief review of in situ/operando X-ray spectroscopic techniques with focus on energy materials is presented, including discussion on current status, choice of cells and suitable X-ray energy range. Initial discussion focuses on the scientific advancement achieved using ambient pressure X-ray photoelectron spectroscopy (APXPS) at the solid/gas interface, and then progresses through the techniques evolution to probe the liquid/vapor and the emerging solid/liquid interface. This is followed by an overview of soft X-ray adsorption spectroscopy (sXAS) for energy science using both window and windowless cell configurations. Concluding remarks provide a future outlook for where the authors believe these techniques and class of science will progress toward.

  8. Energy Dependence of Synchrotron X-Ray Rims in Tycho's Supernova Remnant

    Science.gov (United States)

    Tran, Aaron; Williams, Brian J.; Petre, Robert; Ressler, Sean M.; Reynolds, Stephen P.

    2015-01-01

    Several young supernova remnants exhibit thin X-ray bright rims of synchrotron radiation at their forward shocks. Thin rims require strong magnetic field amplification beyond simple shock compression if rim widths are only limited by electron energy losses. But, magnetic field damping behind the shock could produce similarly thin rims with less extreme field amplification. Variation of rim width with energy may thus discriminate between competing influences on rim widths. We measured rim widths around Tycho's supernova remnant in 5 energy bands using an archival 750 ks Chandra observation. Rims narrow with increasing energy and are well described by either loss-limited or damped scenarios, so X-ray rim width-energy dependence does not uniquely specify a model. But, radio counterparts to thin rims are not loss-limited and better reflect magnetic field structure. Joint radio and X-ray modeling favors magnetic damping in Tycho's SNR with damping lengths approximately 1-5% of remnant radius and magnetic field strengths approximately 50-400 micron G assuming Bohm diffusion. X-ray rim widths are approximately 1% of remnant radius, somewhat smaller than inferred damping lengths. Electron energy losses are important in all models of X-ray rims, suggesting that the distinction between loss-limited and damped models is blurred in soft X-rays. All loss-limited and damping models require magnetic fields approximately greater than 20 micron G, arming the necessity of magnetic field amplification beyond simple compression.

  9. Variable low-energy absorption in the X-ray spectrum of ESO 103-G35

    Energy Technology Data Exchange (ETDEWEB)

    Warwick, R.S.; Pounds, K.A.; Turner, T.J.

    1988-04-15

    EXOSAT observations of the Seyfert 1.9 galaxy, ESO 103-G35, have revealed that this source has a heavily absorbed and variable low-energy X-ray spectrum. Specifically the inferred column density was observed to decrease from approx. 1.7 x 10/sup 23/ to approx. 1.0 x 10/sup 23/ cm/sup -2/ over a 90-day period. This variation is interpreted in terms of an X-ray absorbing screen composed of broad-line clouds moving out of the line-of-sight to the X-ray source.

  10. Determination of plutonium in nitric acid solutions using energy dispersive L X-ray fluorescence with a low power X-ray generator

    Energy Technology Data Exchange (ETDEWEB)

    Py, J. [Laboratoire Chrono-Environnement, UMR CNRS 6249, Université de Franche-Comté, 16 route de Gray, F-25030 Besançon (France); Commissariat à l’Énergie Atomique, Centre de Valduc, F-21120 Is-sur-Tille (France); Groetz, J.-E., E-mail: jegroetz@univ-fcomte.fr [Laboratoire Chrono-Environnement, UMR CNRS 6249, Université de Franche-Comté, 16 route de Gray, F-25030 Besançon (France); Hubinois, J.-C.; Cardona, D. [Commissariat à l’Énergie Atomique, Centre de Valduc, F-21120 Is-sur-Tille (France)

    2015-04-21

    This work presents the development of an in-line energy dispersive L X-ray fluorescence spectrometer set-up, with a low power X-ray generator and a secondary target, for the determination of plutonium concentration in nitric acid solutions. The intensity of the L X-rays from the internal conversion and gamma rays emitted by the daughter nuclei from plutonium is minimized and corrected, in order to eliminate the interferences with the L X-ray fluorescence spectrum. The matrix effects are then corrected by the Compton peak method. A calibration plot for plutonium solutions within the range 0.1–20 g L{sup −1} is given.

  11. Total reflection X-ray fluorescence and energy-dispersive X-ray fluorescence analysis of runoff water and vegetation from abandoned mining of Pb-Zn ores

    Energy Technology Data Exchange (ETDEWEB)

    Marques, A.F.; Queralt, I.; Carvalho, M.L. E-mail: luisa@cii.fc.ul.pt; Bordalo, M

    2003-12-15

    The present work reports on the heavy metal content: Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Cd and Pb in running waters and vegetation around abandoned mining areas. Two species of mosses (Dicranum sp. and Pleurocarpus sp.) and three different species of wild grass (Bromus sp., Rumex sp. and Pseudoavena sp.) growing on the surrounding areas of old lead-zinc mines (Aran Valley, Pyrenees, NE Spain) have been analyzed. Both water and vegetation were collected in two different sampling places: (a) near the mine gallery water outlets and (b) on the landfill close to the abandoned mineral concentration factories. For the heavy metal content determination, two different techniques were used: total reflection X-ray fluorescence for water analysis and energy-dispersive X-ray fluorescence for vegetation study. Surface waters around mine outlets exhibit anomalous content of Co, Ni, Zn, Cd. Stream waters running on mining landfills exhibit higher Cu, Zn, Cd and Pb than those of the waters at the mine gallery outlets. The results allow us to assess the extent of the environmental impact of the mining activities on the water quality. The intake of these elements by vegetation was related with the sampling place, reflecting the metal water content and the substrate chemistry. Accumulation of metals in mosses is higher than those exhibited in wild grasses. Furthermore, different levels of accumulation were found in different wild grass. Rumex sp. presented the lowest metal concentrations, while Pseudoavena sp. reported the highest metal content.

  12. High contrast soft tissue imaging based on multi-energy x-ray

    Science.gov (United States)

    Oh, Hyun-Hwa; Sung, Young-Hun; Kim, Sung-Su; Kwon, Jae-Hyun; Lee, Seong-Deok; Kim, Chang-Yeong

    2011-03-01

    Breast soft tissues have similar x-ray attenuations to mass tissue. Overlapping breast tissue structure often obscures mass and microcalcification, essential to the early detection of breast cancer. In this paper, we propose new method to generate the high contrast mammogram with distinctive features of a breast cancer by using multiple images with different x-ray energy spectra. On the experiments with mammography simulation and real breast tissues, the proposed method has provided noticeable images with obvious mass structure and microcalifications.

  13. Thermal expansion in UO 2 determined by high-energy X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Guthrie, M.; Benmore, C. J.; Skinner, L. B.; Alderman, O. L. G.; Weber, J. K. R.; Parise, J. B.; Williamson, M.

    2016-10-01

    Here we present crystallographic analyses of high-energy X-ray diffraction data on polycrystalline UO2 up to the melting temperature. The Rietveld refinements of our X-ray data are in agreement with previous measurements, but are systematically located around the upper bound of their uncertainty, indicating a slightly steeper trend of thermal expansion compared to established values. This observation is consistent with recent first principles calculations.

  14. Voltage-Thickness-Gray imaging physical model in X-ray energy auto-modulation.

    Science.gov (United States)

    Chen, Ping; Han, Yan; Pan, Jinxiao

    2014-01-01

    Energy auto-modulation is an important tool in X-ray imaging, as it can improve the quality and longevity of an x-ray imaging system. Because of the complex nature of imaged objects, X-ray energy auto-modulation may be difficult. If there is a physical model about imaging mechanism, one can forecast the best imaging parameters using a pre-scan that can be fed into this model. This paper offers a physical model, which is called the Voltage-Thickness-Gray (VTG) model. Based on equivalent single-energy, this paper uses the empirical formula of X-ray attenuation and X-ray photon intensity to build this VTG model. Then use linear regression to estimate the model's parameters, by multi-voltage imaging about the steel wedge block. At last, by the experiment of the steel step block, verify this model and forecast the imaging tube voltage. The result shows this model can better reflect X-ray attenuation imaging properties, and can be used to forecast the imaging voltage. Also the forecast precision can achieve 90% or so.

  15. Calculating the X-Ray Fluorescence from the Planet Mercury Due to High-Energy Electrons

    Science.gov (United States)

    Burbine, T. H.; Trombka, J. I.; Bergstrom, P. M., Jr.; Christon, S. P.

    2005-01-01

    The least-studied terrestrial planet is Mercury due to its proximity to the Sun, which makes telescopic observations and spacecraft encounters difficult. Our lack of knowledge about Mercury should change in the near future due to the recent launching of MESSENGER, a Mercury orbiter. Another mission (BepiColombo) is currently being planned. The x-ray spectrometer on MESSENGER (and planned for BepiColombo) can characterize the elemental composition of a planetary surface by measuring emitted fluorescent x-rays. If electrons are ejected from an atom s inner shell by interaction with energetic particles such as photons, electrons, or ions, electrons from an outer shell can transfer to the inner shell. Characteristic x-rays are then emitted with energies that are the difference between the binding energy of the ion in its excited state and that of the ion in its ground state. Because each element has a unique set of energy levels, each element emits x-rays at a unique set of energies. Electrons and ions usually do not have the needed flux at high energies to cause significant x-ray fluorescence on most planetary bodies. This is not the case for Mercury where high-energy particles were detected during the Mariner 10 flybys. Mercury has an intrinsic magnetic field that deflects the solar wind, resulting in a bow shock in the solar wind and a magnetospheric cavity. Electrons and ions accelerated in the magnetosphere tend to follow its magnetic field lines and can impact the surface on Mercury s dark side Modeling has been done to determine if x-ray fluorescence resulting from the impact of high-energy electrons accelerated in Mercury's magnetosphere can be detected by MESSENGER. Our goal is to understand how much bulk chemical information can be obtained from x-ray fluorescence measurements on the dark side of Mercury.

  16. Dual-energy X-ray absorptiometry for the simultaneous determination of Density and Moisture Content in Porous Structural Materials

    DEFF Research Database (Denmark)

    Hansen, Kurt Kielsgaard; Jensen, Signe Kamp; Gerward, Leif

    1999-01-01

    The paper describes the dual-energy x-ray equipment, which consists of a x-ray source, filters and a detector. The x-ray beam can be moved automatically in two dimensions relative to a fixed specimen. The purpose of the equipment is to measure simultaneously the density and moisture content in po...

  17. Evaluation of the energy dependence of a zinc oxide nanofilm X-ray detector

    Energy Technology Data Exchange (ETDEWEB)

    Valenca, C.P.V., E-mail: claudia.cpvv@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife (Brazil); Silveira, M.A.L.; Macedo, M.A., E-mail: odecamm@gmail.com [Universidade Federal de Sergipe (UFSE), Sao Cristovao, SE (Brazil); Santos, L.A.P, E-mail: lasantos@scients.com.br [Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2015-07-01

    International organizations of human health and radiation protection have recommended certain care for using of the X-ray as a diagnosis tool to avoid any type of radiological accident or overdose to the patient. This can be done assessing the parameters of the X-ray equipment and there are various types of detectors available for that: ionizing chamber, electronic semiconductor devices, etc. These detectors must be calibrated so that they can be used for any energy range and such a procedure is correlated with what is called the energy dependence of the detector. In accordance with the stated requirements of IEC 61267, the standard radiation quality beams and irradiation conditions (RQRs) are the tools and techniques for calibrating diagnostic X-Ray instruments and detectors. The purpose of this work is to evaluate the behavior of the energy dependence of a detector fabricated from a zinc oxide (ZnO) nanofilm. A Pantak industrial X-ray equipment was used to generate the RQR radiation quality beams and test three ZnO detector samples. A 6430 sub-femto-ammeter, Keithley, was used to bias the ZnO detector and simultaneously perform the output readings. The results showed that the ZnO device has some increase in its sensitivity to the ionizing radiation as the X-ray effective energy decreases unlike other types of semiconductor electronic devices typically used as an X-ray detector. We can conclude that the ZnO device can be used as a diagnostic X-ray detector with an appropriate calibration. (author)

  18. Design and Implementation of an Acoustic X-ray Detector to Measure the LCLS Beam Energy

    Energy Technology Data Exchange (ETDEWEB)

    Loos, Jennifer L.; /San Jose State U. /SLAC

    2010-08-25

    On April 11, 2009, first light was seen from LCLS. The present apparatus being used to measure the x-ray beam energy is the Total Energy Sensor which uses a suite of thermal sensors. Another device is needed to cross-check the energy measurements. This new diagnostic tool utilizes radiation acoustic phenomena to determine the x-ray beam energy. A target is hit by the x-rays from the beam, and a voltage is generated in two piezoelectric sensors attached to the target in response to the consequent deformation. Once the voltage is known, the power can be obtained. Thermal sensors will also be attached to the target for calibration purposes. Material selection and design were based on: durability, ultra-high vacuum compatibility, safety and thermal properties. The target material was also chosen for its acoustic properties which were determined from tests using a frequency generator and laser. Initial tests suggest the device will function as anticipated.

  19. X-ray grating interferometry at photon energies over 180 keV

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz-Yaniz, M., E-mail: maite.ruiz-yaniz@esrf.fr [European Synchrotron Radiation Facility, 71 Rue des Martyrs, 38000 Grenoble (France); Lehrstuhl für Biomedizinische Physik, Physik-Department and Institut für Medizintechnik, Technische Universität München, James-Franck-Str. 1, 85748 Garching (Germany); Koch, F.; Meyer, P.; Kunka, D.; Mohr, J. [Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Zanette, I. [Lehrstuhl für Biomedizinische Physik, Physik-Department and Institut für Medizintechnik, Technische Universität München, James-Franck-Str. 1, 85748 Garching (Germany); Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 0DE (United Kingdom); Rack, A. [European Synchrotron Radiation Facility, 71 Rue des Martyrs, 38000 Grenoble (France); Hipp, A. [Institute of Materials Research, Helmholtz-Zentrum Geesthacht, Max-Plank Strasse 1, 21502 Geesthacht (Germany); Pfeiffer, F. [Lehrstuhl für Biomedizinische Physik, Physik-Department and Institut für Medizintechnik, Technische Universität München, James-Franck-Str. 1, 85748 Garching (Germany); Institut für diagnostische und interventionelle Radiologie, Klinikum rechts der Isar, Technische Universität München, 81675 München (Germany)

    2015-04-13

    We report on the implementation and characterization of grating interferometry operating at an x-ray energy of 183 keV. With the possibility to use this technique at high x-ray energies, bigger specimens could be studied in a quantitative way. Also, imaging strongly absorbing specimens will benefit from the advantages of the phase and dark-field signals provided by grating interferometry. However, especially at these high photon energies the performance of the absorption grating becomes a key point on the quality of the system, because the grating lines need to keep their small width of a couple of micrometers and exhibit a greater height of hundreds of micrometers. The performance of high aspect ratio absorption gratings fabricated with different techniques is discussed. Further, a dark-field image of an alkaline multicell battery highlights the potential of high energy x-ray grating based imaging.

  20. Physics-based modeling of X-ray CT measurements with energy-integrating detectors

    Science.gov (United States)

    Long, Yong; Gao, Hewei; Wu, Mingye; Pack, Jed D.; Xu, Hao; Tao, Kun; Fitzgerald, Paul F.; De Man, Bruno

    2014-03-01

    Computer simulation tools for X-ray CT are important for research efforts in developing reconstructionmethods, designing new CT architectures, and improving X-ray source and detector technologies. In this paper, we propose a physics-based modeling method for X-ray CT measurements with energy-integrating detectors. It accurately accounts for the dependence characteristics on energy, depth and spatial location of the X-ray detection process, which is either ignored or over simplified in most existing CT simulation methods. Compared with methods based on Monte Carlo simulations, it is computationally much more efficient due to the use of a look-up table for optical collection efficiency. To model the CT measurments, the proposed model considers five separate effects: energy- and location-dependent absorption of the incident X-rays, conversion of the absorbed X-rays into the optical photons emitted by the scintillator, location-dependent collection of the emitted optical photons, quantumefficiency of converting fromoptical photons to electrons, and electronic noise. We evaluated the proposed method by comparing the noise levels in the reconstructed images from measured data and simulations of a GE LightSpeed VCT system. Using the results of a 20 cm water phantom and a 35 cm polyethylene (PE) disk at various X-ray tube voltages (kVp) and currents (mA), we demonstrated that the proposed method produces realistic CT simulations. The difference in noise standard deviation between measurements and simulations is approximately 2% for the water phantom and 10% for the PE phantom.

  1. Energy Feedback from X-ray Binaries in the Early Universe

    Science.gov (United States)

    Fragos, T.; Lehmer, B..; Naoz, S.; Zezas, A.; Basu-Zych, A.

    2013-01-01

    X-ray photons, because of their long mean-free paths, can easily escape the galactic environments where they are produced, and interact at long distances with the intergalactic medium, potentially having a significant contribution to the heating and reionization of the early universe. The two most important sources of X-ray photons in the universe are active galactic nuclei (AGNs) and X-ray binaries (XRBs). In this Letter we use results from detailed, large scale population synthesis simulations to study the energy feedback of XRBs, from the first galaxies (z (redshift) approximately equal to 20) until today.We estimate that X-ray emission from XRBs dominates over AGN at z (redshift) greater than or approximately equal to 6-8. The shape of the spectral energy distribution of the emission from XRBs shows little change with redshift, in contrast to its normalization which evolves by approximately 4 orders of magnitude, primarily due to the evolution of the cosmic star-formation rate. However, the metallicity and the mean stellar age of a given XRB population affect significantly its X-ray output. Specifically, the X-ray luminosity from high-mass XRBs per unit of star-formation rate varies an order of magnitude going from solar metallicity to less than 10% solar, and the X-ray luminosity from low-mass XRBs per unit of stellar mass peaks at an age of approximately 300 Myr (million years) and then decreases gradually at later times, showing little variation for mean stellar ages 3 Gyr (Giga years, or billion years). Finally, we provide analytical and tabulated prescriptions for the energy output of XRBs, that can be directly incorporated in cosmological simulations.

  2. Development of a low-energy x-ray camera for the imaging of secondary electron bremsstrahlung x-ray emitted during proton irradiation for range estimation

    Science.gov (United States)

    Ando, Koki; Yamaguchi, Mitsutaka; Yamamoto, Seiichi; Toshito, Toshiyuki; Kawachi, Naoki

    2017-06-01

    Imaging of secondary electron bremsstrahlung x-ray emitted during proton irradiation is a possible method for measurement of the proton beam distribution in phantom. However, it is not clear that the method is used for range estimation of protons. For this purpose, we developed a low-energy x-ray camera and conducted imaging of the bremsstrahlung x-ray produced during irradiation of proton beams. We used a 20 mm  ×  20 mm  ×  1 mm finely grooved GAGG scintillator that was optically coupled to a one-inch square high quantum efficiency (HQE)-type position-sensitive photomultiplier tube to form an imaging detector. The imaging detector was encased in a 2 cm-thick tungsten container, and a pinhole collimator was attached to its camera head. After performance of the camera was evaluated, secondary electron bremsstrahlung x-ray imaging was conducted during irradiation of the proton beams for three different proton energies, and the results were compared with Monte Carlo simulation as well as calculated value. The system spatial resolution and sensitivity of the developed x-ray camera with 1.5 mm-diameter pinhole collimator were estimated to be 32 mm FWHM and 5.2  ×  10-7 for ~35 keV x-ray photons at 100 cm from the collimator surface, respectively. We could image the proton beam tracks by measuring the secondary electron bremsstrahlung x-ray during irradiation of the proton beams, and the ranges for different proton energies could be estimated from the images. The measured ranges from the images were well matched with the Monte Carlo simulation, and slightly smaller than the calculated values. We confirmed that the imaging of the secondary electron bremsstrahlung x-ray emitted during proton irradiation with the developed x-ray camera has the potential to be a new tool for proton range estimations.

  3. L-shell X-ray energy shifts for an additional vacancy in the M shell

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, J.; Laha, U.; Talukdar, B.

    1987-04-28

    A relativistic screened hydrogenic model is used to calculate the transition energy shifts of Ll, L eta, L..beta../sub 15/ and L..gamma../sub 1/ x-ray lines for a spectator vacancy in the M/sub v/ subshell for ZETA 57 and ZETA = 60-95 in steps of 5. It is pointed out that, although not very pronounced, the relativistic effect is quite interesting for the L x-ray spectra. Relativity is seen to play an opposite role in affecting the energy shifts for LM and LN transitions. A possible explantation of this is presented in terms of the concept of direct and indirect relativistic effects on atomic orbitals. The present values for /sup 57/La are found to agree quite well with the experimental results of previous workers; also the results indicate that quantum electrodynamic corrections are important in calculating L x-ray transition energy shifts.

  4. Dual-energy x-ray image decomposition by independent component analysis

    Science.gov (United States)

    Jiang, Yifeng; Jiang, Dazong; Zhang, Feng; Zhang, Dengfu; Lin, Gang

    2001-09-01

    The spatial distributions of bone and soft tissue in human body are separated by independent component analysis (ICA) of dual-energy x-ray images. It is because of the dual energy imaging modelí-s conformity to the ICA model that we can apply this method: (1) the absorption in body is mainly caused by photoelectric absorption and Compton scattering; (2) they take place simultaneously but are mutually independent; and (3) for monochromatic x-ray sources the total attenuation is achieved by linear combination of these two absorption. Compared with the conventional method, the proposed one needs no priori information about the accurate x-ray energy magnitude for imaging, while the results of the separation agree well with the conventional one.

  5. Application of dual-energy x-ray techniques for automated food container inspection

    Science.gov (United States)

    Shashishekhar, N.; Veselitza, D.

    2016-02-01

    Manufacturing for plastic food containers often results in small metal particles getting into the containers during the production process. Metal detectors are usually not sensitive enough to detect these metal particles (0.5 mm or lesser), especially when the containers are stacked in large sealed shipping packages; X-ray inspection of these packages provides a viable alternative. This paper presents the results of an investigation into dual-energy X-ray techniques for automated detection of small metal particles in plastic food container packages. The sample packages consist of sealed cardboard boxes containing stacks of food containers: plastic cups for food, and Styrofoam cups for noodles. The primary goal of the investigation was to automatically identify small metal particles down to 0.5 mm diameter in size or less, randomly located within the containers. The multiple container stacks in each box make it virtually impossible to reliably detect the particles with single-energy X-ray techniques either visually or with image processing. The stacks get overlaid in the X-ray image and create many indications almost identical in contrast and size to real metal particles. Dual-energy X-ray techniques were investigated and found to result in a clear separation of the metal particles from the food container stack-ups. Automated image analysis of the resulting images provides reliable detection of the small metal particles.

  6. Evaluation of the effective energy of primary and transmmitted workload weighted X-ray spectra

    Science.gov (United States)

    Santos, J. C.; Costa, P. R.

    2014-02-01

    Current methods for X-ray shielding evaluation for imaging facilities do not take into account the effective energy of the radiation impinging on primary barrier. In addition, the X-ray beam attenuation through the patient is not considered in radiation shielding. The proposed models do not deal with the hardening of the spectra between the primary and transmitted beams. Therefore, the present work proposes the evaluation of X-ray spectra transmitted by an adult patient (anthropomorphic phantom) and a shielding barrier weighted by typical workload distributions. A set of primary spectra produced by a voltage range from 60 to 140 kV was measured with a CdTe spectrometer system. A second set of X-ray spectra transmitted through a 15 mm thickness barite mortar plate was also measured employing the same beam quality and voltage range. The air-kerma was simultaneously measured using an ionization chamber. The primary and transmitted experimental X-ray spectra were weighted by a typical chest examination workload distribution. The resulting weighted spectra represent the superposition of the radiation beams typically used in chest examinations. The effective energy of primary weighted spectra was estimated in 42.4 keV and the effective energy of the corresponding transmitted spectra was estimated in 64.7 keV.

  7. Characterization of the dose perturbation by stents as a function of X-ray beam energy.

    Science.gov (United States)

    Schell, M C; Rosenzweig, D P; Weaver, K A; Fenton, B M; Rubin, P

    1999-01-01

    External beam irradiation of coronary arteries has been shown to be detrimental in an animal model for the prevention of neointimal hyperplasia in the presence of stents when orthovoltage x-ray beams are used. The present study investigated the effect of beam energy on the dose distribution in the wall of the artery in the presence of stents. We used 250-kVp x-rays and 6-MV x-rays to irradiate a stent placed in a homogeneous phantom. Radiochromic film densitometry and Monte Carlo calculations were used to measure and to simulate the dose distribution in the proximity of the stent. External beam irradiation not only failed to prevent neointimal hyperplasia, but actually accentuated the neointimal response to a prompt mechanical injury in the artery. The photoelectric effect, which dominates low-energy x-ray interactions, produces recoil electrons in the stent, which enhance the dose surrounding the intima. The photoelectrons generated in nickel and iron have an extremely short range in normal tissue, approximately 0.1 mm. Initial estimates of orthovoltage x-ray interactions with the stent indicate a dose enhancement in the orthovoltage range by a factor of 2-6 due to the rise in the photoelectric cross section in this energy range depending on the elemental composition of the stent. Film densitometry verifies this dose enhancement. The Monte Carlo calculation yields a dose enhancement and the dose fall-off with distance from the stent when irradiated with orthovoltage x-rays. Conversely when the tissue and stent are irradiated with megavoltage x-rays, the dose enhancement in this region is a factor of 1.15 in close proximity to the stent and 1.0 at distances greater than 0.1 mm. The 6-MV photon interactions in tissue and Ni/Ti are predominantly through Compton scattering. The Compton effect is dependent on the electron density in the medium, in contrast to the atomic number, which is more relevant for photoelectric absorption. The dose estimates for megavoltage x-rays

  8. The chemical sensitivity of X-ray spectroscopy: high energy resolution XANES versus X-ray emission spectroscopy of substituted ferrocenes.

    Science.gov (United States)

    Atkins, Andrew J; Bauer, Matthias; Jacob, Christoph R

    2013-06-07

    X-ray spectroscopy at the metal K-edge is an important tool for understanding catalytic processes and provides insight into the geometric and electronic structures of transition metal complexes. In particular, X-ray emission-based methods such as high-energy resolution fluorescence detection (HERFD), X-ray absorption near-edge spectroscopy (XANES) and valence-to-core X-ray emission spectroscopy (V2C-XES) hold the promise of providing increased chemical sensitivity compared to conventional X-ray absorption spectroscopy. Here, we explore the ability of HERFD-XANES and V2C-XES spectroscopy to distinguish substitutions beyond the directly coordinated atoms for the example of ferrocene and selected ferrocene derivatives. The experimental spectra are assigned and interpreted through the use of density functional theory (DFT) calculations. We find that while the pre-edge peaks in the HERFD-XANES spectra are affected by substituents at the cyclopentadienyl ring containing π-bonds [A. J. Atkins, Ch. R. Jacob and M. Bauer, Chem.-Eur. J., 2012, 18, 7021], the V2C-XES spectra are virtually unchanged. The pre-edge in HERFD-XANES probes the weak transition to unoccupied metal d-orbitals, while the V2C-XES spectra are determined by dipole-allowed transitions from occupied ligand orbitals to the 1s core hole. The latter turn out to be less sensitive to changes beyond the first coordination shell.

  9. Validation of a New Skinfold Prediction Equation Based on Dual-Energy X-Ray Absorptiometry

    Science.gov (United States)

    Ball, Stephen; Cowan, Celsi; Thyfault, John; LaFontaine, Tom

    2014-01-01

    Skinfold prediction equations recommended by the American College of Sports Medicine underestimate body fat percentage. The purpose of this research was to validate an alternative equation for men created from dual energy x-ray absorptiometry. Two hundred ninety-seven males, aged 18-65, completed a skinfold assessment and dual energy x-ray…

  10. An investigation of X-ray and radio isotope energy absorption of ...

    Indian Academy of Sciences (India)

    Abstract. This study investigated the X-ray and radioisotope energy absorption capacity of heavyweight concrete containing barite aggregate. Concrete plates were prepared using differing amounts of barite aggregate instead of normal aggregate. Density–thickness–energy variations of these concretes for 85 keV, 118 keV, ...

  11. An investigation of X-ray and radio isotope energy absorption of ...

    Indian Academy of Sciences (India)

    This study investigated the X-ray and radioisotope energy absorption capacity of heavyweight concrete containing barite aggregate. Concrete plates were prepared using differing amounts of barite aggregate instead of normal aggregate. Density–thickness–energy variations of these concretes for 85 keV, 118 keV, 164 keV, ...

  12. Measurement of mass attenuation coefficients of biological materials by energy dispersive X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ekinci, N. [Science and Art Faculty, Department of Physics, Atatuerk University, 25240 Erzurum (Turkey)]. E-mail: nekinci@atauni.edu.tr; Astam, N. [Faculty of Medicine, Department of Ophthalmology, Atatuerk University, Erzurum (Turkey)

    2007-03-15

    The mass attenuation coefficients for cornea taken from keratitis patient and soft contact lens (-1.75, -3.75, -4 dioptres), leiomyomata uteri and uterus were measured in the X-ray energy (5.9keV) using a SiLi detector and Fe{sup 55} annular source. Full details of the experimental method, experimental set up, the procedure of sample preparation and the results within estimated error are presented. Energy dispersive X-ray fluorescence technique has been successfully used for the determination of the mass attenuation coefficients.

  13. Focusing Optics for High-Energy X-ray Diffraction

    DEFF Research Database (Denmark)

    Leinert, U.; Schulze, C.; Honkimäki, V.

    1998-01-01

    Novel focusing optical devices have been developed for synchrotron radiation in the energy range 40-100 keV. Firstly, a narrow-band-pass focusing energy-tuneable fixed-exit monochromator was constructed by combining meridionally bent Laue and Bragg crystals. Dispersion compensation was applied...

  14. Ice core stratigraphy using dual energy x-ray absorptiometry (DEXA)

    Energy Technology Data Exchange (ETDEWEB)

    Kroger, Chris [Institute of Geological and Nuclear Sciences, PO Box 31312, Wellington (New Zealand); Thomson, Julian [Victoria University Wellington, Wellington (New Zealand); Bertler, Nancy [Victoria University Wellington, Wellington (New Zealand); Morgenstern, Uwe [Institute of Geological and Nuclear Sciences, PO Box 31312, Wellington (New Zealand)

    2006-05-15

    We are presenting a technique using x-rays to detect strata caused by density variation in 94 mm diameter ice cores. Moreover, high resolution density is determined. A 54 m long ice core retrieved from the Tasman Glacier of the Southern Alps in New Zealand has been x-ray scanned and the images were analysed. As a dual energy capable x-ray (DEXA) scanner was used, DEXA analysis techniques were used where appropriate, such as for the enhancement of strata visibility in the images. Density calculations though were based on a single energy model, using the fundamental law of x-ray attenuation. As the model does not precisely reflect realistic conditions, calibrations were made for the material properties and pixel scaling. Results of detected strata were compared to traditional visual light methods, where up to a depth of {approx}35 m better detail was achieved using x-rays. Density data was checked against the average volumetric density. Results compare well with the volumetric density, however a small bias exists, which at present requires further investigation.

  15. Determination of the energy or pressure of a solar X-ray structure using X-ray filtergrams from a single filter

    Science.gov (United States)

    Kahler, S.

    1976-01-01

    While the X-ray fluxes measured through two different broadband filters can be used to derive the temperatures and emission measures of solar plasmas, it is generally assumed that no plasma parameters can be measured quantitatively with a single filtergram alone. It is shown that the thermal energy density (or pressure) of a solar plasma can be measured with an ideal single filtergram. Calculations have been done to compare the properties of the Skylab S-054 X-ray telescope filters with those of the ideal filter.

  16. Time-delayed beam splitting with energy separation of x-ray channels

    Energy Technology Data Exchange (ETDEWEB)

    Stetsko, Yuri P.; Shvyd' ko, Yuri V.; Brian Stephenson, G. [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States)

    2013-10-21

    We introduce a time-delayed beam splitting method based on the energy separation of x-ray photon beams. It is implemented and theoretically substantiated on an example of an x-ray optical scheme similar to that of the classical Michelson interferometer. The splitter/mixer uses Bragg-case diffraction from a thin diamond crystal. Another two diamond crystals are used as back-reflectors. Because of energy separation and a minimal number (three) of optical elements, the split-delay line has high efficiency and is simple to operate. Due to the high transparency of diamond crystal, the split-delay line can be used in a beam sharing mode at x-ray free-electron laser facilities.

  17. The HERO Program: High-Energy Replicated Optics for a Hard-X-Ray Balloon Payload

    Science.gov (United States)

    Ramsey, B. D.; Engelhaupt, D.; Speegle, C. O.; Austin, R. A.; Kolodziejczak, J. J.; ODell, S. L.; Weisskopf, M. C.

    1999-01-01

    We are developing high-energy replicated optics for a balloon-borne hard-x-ray telescope. When completed, the telescope will have around 150 square cm of effective collecting area up to 65 keV, and an angular resolution of around 30 arc seconds, half power diameter. When used in conjunction with an array of focal plane imaging detectors, for which Gas Scintillation Proportional Counters are under development, the payload will provide unprecedented sensitivity for pointed observations in the hard-x-ray band. We will present an overview of the High Energy Replicated Optics (HERO) program together with test data from the first mirror units. The overall sensitivity of the full payload, when flown on long- and ultra-long-duration balloon flights, will be compared with past and planned satellite-borne hard-x-ray missions.

  18. High-energy synchrotron X-ray radiography of shock-compressed materials

    Science.gov (United States)

    Rutherford, Michael E.; Chapman, David J.; Collinson, Mark A.; Jones, David R.; Music, Jasmina; Stafford, Samuel J. P.; Tear, Gareth R.; White, Thomas G.; Winters, John B. R.; Drakopoulos, Michael; Eakins, Daniel E.

    2015-06-01

    This presentation will discuss the development and application of a high-energy (50 to 250 keV) synchrotron X-ray imaging method to study shock-compressed, high-Z samples at Beamline I12 at the Diamond Light Source synchrotron (Rutherford-Appleton Laboratory, UK). Shock waves are driven into materials using a portable, single-stage gas gun designed by the Institute of Shock Physics. Following plate impact, material deformation is probed in-situ by white-beam X-ray radiography and complimentary velocimetry diagnostics. The high energies, large beam size (13 x 13 mm), and appreciable sample volumes (~ 1 cm3) viable for study at Beamline I12 compliment existing in-house pulsed X-ray capabilities and studies at the Dynamic Compression Sector. The authors gratefully acknowledge the ongoing support of Imperial College London, EPSRC, STFC and the Diamond Light Source, and AWE Plc.

  19. Fast GPU-based spot extraction for energy-dispersive X-ray Laue diffraction

    Science.gov (United States)

    Alghabi, F.; Send, S.; Schipper, U.; Abboud, A.; Pashniak, N.; Pietsch, U.; Kolb, A.

    2014-11-01

    This paper describes a novel method for fast online analysis of X-ray Laue spots taken by means of an energy-dispersive X-ray 2D detector. Current pnCCD detectors typically operate at some 100 Hz (up to a maximum of 400 Hz) and have a resolution of 384 × 384 pixels, future devices head for even higher pixel counts and frame rates. The proposed online data analysis is based on a computer utilizing multiple Graphics Processing Units (GPUs), which allow for fast and parallel data processing. Our multi-GPU based algorithm is compliant with the rules of stream-based data processing, for which GPUs are optimized. The paper's main contribution is therefore an alternative algorithm for the determination of spot positions and energies over the full sequence of pnCCD data frames. Furthermore, an improved background suppression algorithm is presented.The resulting system is able to process data at the maximum acquisition rate of 400 Hz. We present a detailed analysis of the spot positions and energies deduced from a prior (single-core) CPU-based and the novel GPU-based data processing, showing that the parallel computed results using the GPU implementation are at least of the same quality as prior CPU-based results. Furthermore, the GPU-based algorithm is able to speed up the data processing by a factor of 7 (in comparison to single-core CPU-based algorithm) which effectively makes the detector system more suitable for online data processing.

  20. Diffractometer for high energy X-rays at the APS

    CERN Document Server

    Rütt, U; Strempfer, J; Jennings, G; Kurtz, C; Montano, P A

    2001-01-01

    The Basic Energy Sciences Synchrotron Radiation Center (BESSRC) has designed and built a diffractometer specialized for high energy synchrotron radiation (E>60 keV) at the Advanced Photon Source (APS). The diffractometer, which is installed at the elliptical multipole wiggler, uses linearly polarized light (U. Ruett et al., Proc. SPIE 3348 (1998) 132.). The instrument is a triple-axis diffractometer allowing high resolution measurement in two dimensions of the reciprocal space. As opposed to the other diffractometers for high photon energies at HASYLAB (Germany) and ESRF (France) (R. Bouchard et al., 5 (1998) 90; K.-D. Liss et al., J. Synchrotron Rad. 5 (1998) 82), this diffractometer utilizes the vertical scattering plane to take full advantage of the small vertical divergence of the beam and to allow horizontal focusing of the broad beam from the wiggler without disturbing the resolution of the instrument. The instrument is designed to carry heavy sample equipment up to a weight of 200 kg, while maintaining...

  1. Preliminary Research on Dual-Energy X-Ray Phase-Contrast Imaging

    CERN Document Server

    Han, Huajie; Gao, Kun; Wang, Zhili; Zhang, Can; Yang, Meng; Zhang, Kai; Zhu, Peiping

    2015-01-01

    Dual-energy X-ray absorptiometry (DEXA) has been widely applied to measure bone mineral density (BMD) and soft-tissue composition of human body. However, the use of DEXA is greatly limited for low-Z materials such as soft tissues due to their weak absorption. While X-ray phase-contrast imaging (XPCI) shows significantly improved contrast in comparison with the conventional standard absorption-based X-ray imaging for soft tissues. In this paper, we propose a novel X-ray phase-contrast method to measure the area density of low-Z materials, including a single-energy method and a dual-energy method. The single-energy method is for the area density calculation of one low-Z material, while the dual-energy method is aiming to calculate the area densities of two low-Z materials simultaneously. Comparing the experimental and simulation results with the theoretic ones, the new method proves to have the potential to replace DEXA in area density measurement. The new method sets the prerequisites for future precise and lo...

  2. Measurements of X-ray relectivities of Au-coatings at several energies

    DEFF Research Database (Denmark)

    Hornstrup, Allan; Christensen, Finn Erland; Garnaes, J.

    1990-01-01

    We present the results of an extensive study of X-ray reflectivities of dip lacquered and Au-coated Al foils. The measurements are performed at four different energies from 0.71 keV to 8.1 keV. The foils span a range of fabrication parameters. We show that two of three examined versions...... of a density variation model are able to explain the data. We find a strong dependence on the microroughness of thickness of the Au coating and of the Au deposition rates. We present data suggesting important correspondence between X-ray measurements and scanning tunneling microscopy measurements. We find...

  3. Radiation dose in radius bone mineral density measurements using dual energy X-ray absorptiometry. Dosimetric method on scan beam

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Ichiro; Ogata, Hiromitsu; Izumo, Yoshiro [Institute of Public Health, Tokyo (Japan); Ohkubo, Makoto; Kato, Akira

    2001-12-01

    Effective doses in radius bone mineral density measurements using dual energy X-ray absorptiometry (DEXA) were assessed with entrance beam intensity and X-ray absorption rate in organs. The X-ray entrance beam intensity was calculated from an energy fluence rate, and we demonstrated how to assess beam intensity by using thermoluminescent dosimeters (TLDs). The entrance beam energies were calculated from X-ray beam intensity in regard to beam sizes, scan areas, and scan times. The X-ray absorption rates were calculated by using X-ray absorption curves at bone mineral density measurements. The average tissue doses were determined by using reference female and men. Skin entrance intensity was 4 x 10{sup -4} [J/(m{sup 2}{center_dot}s)]. Skin entrance energies were 1-2 x 10{sup -3} [J] in proportion to wrist width. The effective dose was approximately 5 nSv. (author)

  4. Photoemission Yields at Low X-Ray Energies.

    Science.gov (United States)

    1979-10-30

    I II YT YP AERODAG - -c----- MYLAR -’-- 10-2 -- 1Ŕ-2 % : ’\\ , - 0 % z * ’ * 0 C,I * Ti -0-- Ti 196 19* 2 x 10 -4 _ 10 -3 _ 1 1 2 3 4 568 10 1 2 3 4...56 810 PHOTON ENERGY (k@V) Figure 8. Photoelectron yields from Aerodag (carbon), Mylar, Saran (chlorine) and titanium. 9i - - - . 3. Titanium: A foil...with a conductive Aerodag backing. The composition was not determined, but the predominant SiO 2 most likely had significant amounts of the normal

  5. Energy-dispersive X-ray microanalysis of elements' content and ...

    African Journals Online (AJOL)

    This study was designed to investigate elements' content and anti-microbial effects of two Malaysian plants, Pereskia bleo and Goniothalamus umbrosus. Elements' analysis was carried out using Energy Dispersive X-ray Microanalysis combined with Variable Pressure Scanning Electron Microscope (EDX, VPSEM).

  6. Low-energy gamma-ray spectroscopy using an X-ray-escape gated proportional counter

    DEFF Research Database (Denmark)

    Gregers Hansen, P.; Nielsen, H.L.; Williams, E.T.

    1965-01-01

    The utility of a gas-filled proportional counter in low-energy γ spectroscopy is greatly increased if it is operated in coincidence with an escaping fluorescent X-ray. An apparatus, having an efficiency greater than 10% of singles, is described and several examples are given. An efficiency curve...

  7. Energy-dispersive X-ray diffraction beamline at Indus-2 synchrotron ...

    Indian Academy of Sciences (India)

    Abstract. An energy-dispersive X-ray diffraction beamline has been designed, developed and commissioned at BL-11 bending magnet port of the Indian synchrotron source, Indus-2. The performance of this beamline has been benchmarked by measuring diffraction patterns from var- ious elemental metals and standard ...

  8. Evaluation of dual-energy radiography with a digital x-ray detector

    Science.gov (United States)

    Guillemaud, Regis; Robert-Coutant, Christine; Darboux, Michel; Gagelin, Jean J.; Dinten, Jean-Marc

    2001-06-01

    Dual-energy imaging has been proposed as a method for producing material-specific images, thus permitting separate examination of bone and soft-tissue structures. Interesting clinical results, particularly for chest, have been presented usually for screen-film or phosphor plate detectors and with single exposure. The purpose of the paper is to investigate double exposure dual-energy with a digital X-Ray detector. The study is performed with a CCD-based large field digital X-Ray detector (Paladio detector, Apelem) installed on a remote table. Dual exposure is feasible on this detector with little registration problem because we have a very short delay (X-ray tube filtrations. X-ray generator energy voltages and filtrations are optimized in order to obtain thin energy peak spectra with good spectral separation (50 keV), much better than with single exposure systems. Tissue decomposition images are estimated from both acquisitions. The decomposition process is helped by the nice spectral separation. Scatter correction, applied to the raw dual-exposure acquisitions, provides an improvement of tissue decomposition. Results are shown for a chest phantom.

  9. Energy-Dispersive X-Ray Fluorescence Spectrometry: A Long Overdue Addition to the Chemistry Curriculum

    Science.gov (United States)

    Palmer, Peter T.

    2011-01-01

    Portable Energy-Dispersive X-Ray Fluorescence (XRF) analyzers have undergone significant improvements over the past decade. Salient advantages of XRF for elemental analysis include minimal sample preparation, multielement analysis capabilities, detection limits in the low parts per million (ppm) range, and analysis times on the order of 1 min.…

  10. High energy X-ray spectrometer on the Chandrayaan-1 mission to ...

    Indian Academy of Sciences (India)

    The Chandrayaan-1 mission to the Moon scheduled for launch in late 2007 will include a high energy X-ray spectrometer (HEX) for detection of naturally occurring emissions from the lunar surface due to radioactive decay of ... Space Astronomy and Instrumentation Division, ISRO Satellite Center, Bangalore 560 017, India.

  11. Solar X-ray Spectrometer (SOXS) Mission – Low Energy Payload ...

    Indian Academy of Sciences (India)

    ... of 'Solar X-ray Spectrometer (SOXS)' mission, which was launched onboard GSAT-2 Indian spacecraft on 08 May 2003 by GSLV-D2 rocket to study the solar flares. The SOXS Low Energy Detector (SLD) payload was designed, developed and fabricated by Physical Research Laboratory. (PRL) in collaboration with Space ...

  12. Grating Oriented Line-Wise Filtration (GOLF) for Dual-Energy X-ray CT

    Science.gov (United States)

    Xi, Yan; Cong, Wenxiang; Harrison, Daniel; Wang, Ge

    2017-12-01

    In medical X-ray Computed Tomography (CT), the use of two distinct X-ray source spectra (energies) allows dose-reduction and material discrimination relative to that achieved with only one source spectrum. Existing dual-energy CT methods include source kVp-switching, double-layer detection, dual-source gantry, and two-pass scanning. Each method suffers either from strong spectral correlation or patient-motion artifacts. To simultaneously address these problems, we propose to improve CT data acquisition with the Grating Oriented Line-wise Filtration (GOLF) method, a novel X-ray filter that is placed between the source and patient. GOLF uses a combination of absorption and filtering gratings that are moved relative to each other and in synchronization with the X-ray tube kVp-switching process and/or the detector view-sampling process. Simulation results show that GOLF can improve the spectral performance of kVp-switching to match that of dual-source CT while avoiding patient motion artifacts and dual imaging chains. Although significant flux is absorbed by this pre-patient filter, the proposed GOLF method is a novel path for cost-effectively extracting dual-energy or multi-energy data and reducing radiation dose with or without kVp switching.

  13. Energy-dispersive X-ray fluorescence study of elemental uptake in ...

    Indian Academy of Sciences (India)

    A109Cd radioisotope-induced energy-dispersive X-ray fluorescence (EDXRF) study has been performed on samples of cauliflower consisting of the flower, the leaves and the associated root soil. The cauliflowers were collected from farms near the main dumping site of municipal solid waste in the city of Kolkata, India and ...

  14. High Miller-index germanium crystals for high-energy x-ray imaging applications.

    Science.gov (United States)

    Koch, J A; Lee, J J; Haugh, M J

    2015-12-01

    Near-normal-incidence bent crystals are widely used for x-ray imaging applications. Advantages include high collection solid angle and potentially high efficiency for narrow-band sources, while disadvantages include relatively large (several Å) interatomic spacings and a limited number of suitable matches between a crystal 2d value and an integral multiple of useful emission line wavelengths. The disadvantages become more significant at x-ray energies >10  keV. The former disadvantage can be mitigated by using high-order reflections from crystal planes having low Miller indices, but both disadvantages can be mitigated by using low-order reflections from crystal planes having high Miller indices. We report here on integrated reflectivity measurements we performed of Ge (15,7,7) (2d=0.6296  Å), a candidate for imaging Ru He-α (θ(B)=87°). We find good agreement with calculations, and the data show a multitude of closely spaced reflections with slightly different Bragg angles including a fifth-order reflection of Ge (3,1,1) that has comparable reflectivity. This demonstrates that arbitrary choices of Miller indices in Ge crystals can be used to fine-tune Bragg angles for near-normal-incidence x-ray imaging at tens of kiloelectron volt x-ray energies with minimal lower-energy contamination from lower-order reflections, and that existing calculational tools can be used to reliably estimate integrated reflectivity.

  15. Normoxic polyacrylamide gel doped with iodine: Response versus X-ray energy

    Energy Technology Data Exchange (ETDEWEB)

    Gastaldo, Jerome [Institut National de la Sante et de la Recherche Medicale, Unite 836, Grenoble Institut des Neurosciences, Equipe ' Rayonnement synchrotron et recherche medicale' , Grenoble F-38043, Cedex 9 (France); Universite Joseph Fourier, Grenoble F-38041, Cedex 9 (France); European Synchrotron Radiation Facility, F-38043 Grenoble Cedex 9 (France)], E-mail: Gastaldo.jerome@free.fr; Boudou, Caroline [Institut National de la Sante et de la Recherche Medicale, Unite 836, Grenoble Institut des Neurosciences, Equipe ' Rayonnement synchrotron et recherche medicale' , Grenoble F-38043, Cedex 9 (France); Universite Joseph Fourier, Grenoble F-38041, Cedex 9 (France); European Synchrotron Radiation Facility, F-38043 Grenoble Cedex 9 (France)], E-mail: caroline.boudou@voila.fr; Lamalle, Laurent [IFR 1, RMN Biomedicale et neuroscience, Centre Hospitalier Universitaire de Grenoble - Unite IRM 3T, Grenoble F-38043, Cedex 9 (France)], E-mail: Laurent.Lamalle@ujf-grenoble.fr; Tropres, Irene [IFR 1, RMN Biomedicale et neuroscience, Centre Hospitalier Universitaire de Grenoble - Unite IRM 3T, Grenoble F-38043, Cedex 9 (France)], E-mail: irene.tropres@ujf-grenoble.fr; Corde, Stephanie [Centre Hospitalier Universitaire de Grenoble, departement de Radiotherapie Grenoble F-38043, Cedex 9 (France)], E-mail: SCordetehei@chu-grenoble.fr; Sollier, Alberic; Rucka, Guenther [Centre Hospitalier Universitaire de Grenoble, departement de Radiotherapie Grenoble F-38043, Cedex 9 (France); Elleaume, Helene [Institut National de la Sante et de la Recherche Medicale, Unite 836, Grenoble Institut des Neurosciences, Equipe ' Rayonnement synchrotron et recherche medicale' , Grenoble F-38043, Cedex 9 (France); Universite Joseph Fourier, Grenoble F-38041, Cedex 9 (France); European Synchrotron Radiation Facility, F-38043 Grenoble Cedex 9 (France)], E-mail: H.Elleaume@esrf.fr

    2008-12-15

    The basis of Synchrotron Stereotactic Radio-Therapy (SSRT) is the incorporation of high atomic number atoms (iodine, for example) into the tumour mass followed by an irradiation with a monochromatic, low energy, X-ray beam from a synchrotron source. The purpose of the present study was to determine whether polymer gel dosimetry could be used to measure the enhancement of absorbed energy induced by the iodine in the media. We have used a standard nPAG formulation, loaded with NaI and the irradiations were performed either with monochromatic X-rays at the ESRF medical beamline or with a conventional 6 MV X-ray beam from a linear accelerator at the Grenoble University Hospital. We observed sensitivity increase with iodine loaded gels irradiated at low energies, in good agreement with the theoretical iodine dose-enhancement. As expected, the response of the iodine-doped polymer gel was not increased after irradiation with mega-voltage X-rays. We demonstrate in this study that polymer gel dosimeters can be used for measuring dose-enhancement due to iodine presence in SSR treatment.

  16. Energy-windowed, pixellated X-ray diffraction using the Pixirad CdTe detector

    Science.gov (United States)

    O'Flynn, D.; Bellazzini, R.; Minuti, M.; Brez, A.; Pinchera, M.; Spandre, G.; Moss, R.; Speller, R. D.

    2017-01-01

    X-ray diffraction (XRD) is a powerful tool for material identification. In order to interpret XRD data, knowledge is required of the scattering angles and energies of X-rays which interact with the sample. By using a pixellated, energy-resolving detector, this knowledge can be gained when using a spectrum of unfiltered X-rays, and without the need to collimate the scattered radiation. Here we present results of XRD measurements taken with the Pixirad detector and a laboratory-based X-ray source. The cadmium telluride sensor allows energy windows to be selected, and the 62 μm pixel pitch enables accurate spatial information to be preserved for XRD measurements, in addition to the ability to take high resolution radiographic images. Diffraction data are presented for a variety of samples to demonstrate the capability of the technique for materials discrimination in laboratory, security and pharmaceutical environments. Distinct diffraction patterns were obtained, from which details on the molecular structures of the items under study were determined.

  17. Internal strains and stresses measured in cortical bone via high-energy x-ray diffraction.

    Energy Technology Data Exchange (ETDEWEB)

    Almer, J. D.; Stock, S. R.; Experimental Facilities Division (APS); Northwestern Univ.,

    2005-01-01

    High-energy synchrotron X-ray diffraction was used to study internal stresses in bone under in situ compressive loading. A transverse cross-section of a 12-14 year old beagle fibula was studied with 80.7 keV radiation, and the transmission geometry was used to quantify internal strains and corresponding stresses in the mineral phase, carbonated hydroxyapatite. The diffraction patterns agreed with tabulated patterns, and the distribution of diffracted intensity around 00.2/00.4 and 22.2 diffraction rings was consistent with the imperfect 00.1 fiber texture expected along the axis of a long bone. Residual compressive stress along the bone's longitudinal axis was observed in the specimen prior to testing: for 22.2 this stress equaled -95 MPa and for 00.2/00.4 was between -160 and -240 MPa. Diffraction patterns were collected for applied compressive stresses up to -110 MPa, and, up to about -100 MPa, internal stresses rose proportionally with applied stress but at a higher rate, corresponding to stress concentration in the mineral of 2.8 times the stress applied. The widths of the 00.2 and 00.4 diffraction peaks indicated that crystallite size perpendicular to the 00.1 planes increased from t = 41 nm before stress was applied to t = 44 nm at -118 MPa applied stress and that rms strain {var_epsilon}{sub rms} rose from 2200 {mu}{var_epsilon} before loading to 4600 {mu}{var_epsilon} at the maximum applied stress. Small angle X-ray scattering of the unloaded sample, recorded after deformation was complete, showed a collagen D-period of 66.4 nm (along the bone axis).

  18. Determination of the weld thickness of turbine for aircraft engine by high-energy X-ray tomography

    OpenAIRE

    Zhong Yang; Chakhlov Sergei; Mamyrbayev Talgat

    2017-01-01

    It is necessary to test the weld thickness of turbine, as it is one of the most important parts for aircraft engine. The weld thickness of turbine for aircraft engine by high-energy X-ray tomography was determined. We used an X-ray tube and a betatron as X-ray sources. The wall thickness of two tubes and weld thickness of turbine were measured. It is shown that the high-energy X-ray tomography system is determined the wall thickness of the tube and the weld thickness of turbine with high accu...

  19. High-energy neutrino fluxes from AGN populations inferred from X-ray surveys

    Science.gov (United States)

    Jacobsen, Idunn B.; Wu, Kinwah; On, Alvina Y. L.; Saxton, Curtis J.

    2015-08-01

    High-energy neutrinos and photons are complementary messengers, probing violent astrophysical processes and structural evolution of the Universe. X-ray and neutrino observations jointly constrain conditions in active galactic nuclei (AGN) jets: their baryonic and leptonic contents, and particle production efficiency. Testing two standard neutrino production models for local source Cen A (Koers & Tinyakov and Becker & Biermann), we calculate the high-energy neutrino spectra of single AGN sources and derive the flux of high-energy neutrinos expected for the current epoch. Assuming that accretion determines both X-rays and particle creation, our parametric scaling relations predict neutrino yield in various AGN classes. We derive redshift-dependent number densities of each class, from Chandra and Swift/BAT X-ray luminosity functions (Silverman et al. and Ajello et al.). We integrate the neutrino spectrum expected from the cumulative history of AGN (correcting for cosmological and source effects, e.g. jet orientation and beaming). Both emission scenarios yield neutrino fluxes well above limits set by IceCube (by ˜4-106 × at 1 PeV, depending on the assumed jet models for neutrino production). This implies that: (i) Cen A might not be a typical neutrino source as commonly assumed; (ii) both neutrino production models overestimate the efficiency; (iii) neutrino luminosity scales with accretion power differently among AGN classes and hence does not follow X-ray luminosity universally; (iv) some AGN are neutrino-quiet (e.g. below a power threshold for neutrino production); (v) neutrino and X-ray emission have different duty cycles (e.g. jets alternate between baryonic and leptonic flows); or (vi) some combination of the above.

  20. Feasibility of using intermediate x-ray energies for highly conformal extracranial radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Peng; Yu, Victoria; Nguyen, Dan; Demarco, John; Low, Daniel A.; Sheng, Ke, E-mail: ksheng@mednet.ucla.edy [Department of Radiation Oncology, University of California Los Angeles, California 90095 (United States); Woods, Kaley; Boucher, Salime [RadiaBeam Technologies, Santa Monica, California 90404 (United States)

    2014-04-15

    Purpose: To investigate the feasibility of using intermediate energy 2 MV x-rays for extracranial robotic intensity modulated radiation therapy. Methods: Two megavolts flattening filter free x-rays were simulated using the Monte Carlo code MCNP (v4c). A convolution/superposition dose calculation program was tuned to match the Monte Carlo calculation. The modeled 2 MV x-rays and actual 6 MV flattened x-rays from existing Varian Linacs were used in integrated beam orientation and fluence optimization for a head and neck, a liver, a lung, and a partial breast treatment. A column generation algorithm was used for the intensity modulation and beam orientation optimization. Identical optimization parameters were applied in three different planning modes for each site: 2, 6 MV, and dual energy 2/6 MV. Results: Excellent agreement was observed between the convolution/superposition and the Monte Carlo calculated percent depth dose profiles. For the patient plans, overall, the 2/6 MV x-ray plans had the best dosimetry followed by 2 MV only and 6 MV only plans. Between the two single energy plans, the PTV coverage was equivalent but 2 MV x-rays improved organs-at-risk sparing. For the head and neck case, the 2MV plan reduced lips, mandible, tongue, oral cavity, brain, larynx, left and right parotid gland mean doses by 14%, 8%, 4%, 14%, 24%, 6%, 30% and 16%, respectively. For the liver case, the 2 MV plan reduced the liver and body mean doses by 17% and 18%, respectively. For the lung case, lung V20, V10, and V5 were reduced by 13%, 25%, and 30%, respectively. V10 of heart with 2 MV plan was reduced by 59%. For the partial breast treatment, the 2 MV plan reduced the mean dose to the ipsilateral and contralateral lungs by 27% and 47%, respectively. The mean body dose was reduced by 16%. Conclusions: The authors showed the feasibility of using flattening filter free 2 MV x-rays for extracranial treatments as evidenced by equivalent or superior dosimetry compared to 6 MV plans

  1. Developing a bright 17 keV x-ray source for probing high-energy-density states of matter at high spatial resolution

    Energy Technology Data Exchange (ETDEWEB)

    Huntington, C. M.; Park, H.-S.; Maddox, B. R.; Barrios, M. A.; Benedetti, R.; Braun, D. G.; Landen, O. L.; Wehrenberg, C. E.; Remington, B. A. [Lawrence Livermore National Laboratory, Livermore, California, 94551 (United States); Hohenberger, M.; Regan, S. P. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States)

    2015-04-15

    A set of experiments were performed on the National Ignition Facility (NIF) to develop and optimize a bright, 17 keV x-ray backlighter probe using laser-irradiated Nb foils. High-resolution one-dimensional imaging was achieved using a 15 μm wide slit in a Ta substrate to aperture the Nb He{sub α} x-rays onto an open-aperture, time integrated camera. To optimize the x-ray source for imaging applications, the effect of laser pulse shape and spatial profile on the target was investigated. Two laser pulse shapes were used—a “prepulse” shape that included a 3 ns, low-intensity laser foot preceding the high-energy 2 ns square main laser drive, and a pulse without the laser foot. The laser spatial profile was varied by the use of continuous phase plates (CPPs) on a pair of shots compared to beams at best focus, without CPPs. A comprehensive set of common diagnostics allowed for a direct comparison of imaging resolution, total x-ray conversion efficiency, and x-ray spectrum between shots. The use of CPPs was seen to reduce the high-energy tail of the x-ray spectrum, whereas the laser pulse shape had little effect on the high-energy tail. The measured imaging resolution was comparably high for all combinations of laser parameters, but a higher x-ray flux was achieved without phase plates. This increased flux was the result of smaller laser spot sizes, which allowed us to arrange the laser focal spots from multiple beams and produce an x-ray source which was more localized behind the slit aperture. Our experiments are a first demonstration of point-projection geometry imaging at NIF at the energies (>10 keV) necessary for imaging denser, higher-Z targets than have previously been investigated.

  2. Energy Calibration of the Pixels of Spectral X-ray Detectors

    CERN Document Server

    Panta, Raj Kumar; Bell, Stephen T; Anderson, Nigel G; Butler, Anthony P; Butler, Philip H

    2015-01-01

    The energy information acquired using spectral X-ray detectors allows noninvasive identification and characterization of chemical components of a material. To achieve this, it is important that the energy response of the detector is calibrated. The established techniques for energy calibration are not practical for routine use in pre-clinical or clinical research environment. This is due to the requirements of using monochromatic radiation sources such as synchrotron, radio-isotopes, and prohibitively long time needed to set up the equipment and make measurements. To address these limitations, we have developed an automated technique for calibrating the energy response of the pixels in a spectral X-ray detector that runs with minimal user intervention. This technique uses the X-ray tube voltage (kVp) as a reference energy, which is stepped through an energy range of interest. This technique locates the energy threshold where a pixel transitions from not-counting (off) to counting (on). Similarly, we have deve...

  3. L X-ray energy shifts and intensity ratios in tantalum with C and N ions

    Indian Academy of Sciences (India)

    Abstract. The energy shifts and intensity ratios of different L X-ray components in tantalum el- ement due to 10 MeV carbon and 12 MeV nitrogen ions are estimated. From the observed energy shifts, the possible number of simultaneous vacancies in M shell are estimated. A comparison of. Lα/Lβ2 15. , Lβ1. /Lγ1 and Lγ2 ...

  4. L X-ray energy shifts and intensity ratios in tantalum with C and N ...

    Indian Academy of Sciences (India)

    The energy shifts and intensity ratios of different L X-ray components in tantalum element due to 10 MeV carbon and 12 MeV nitrogen ions are estimated. From the observed energy shifts, the possible number of simultaneous vacancies in M shell are estimated. A comparison of L/L 2,15, L 1/L 1 and L 2,3/L 4,4 with ...

  5. High-energy Neutrino Flares from X-Ray Bright and Dark Tidal Disruption Events

    Energy Technology Data Exchange (ETDEWEB)

    Senno, Nicholas; Murase, Kohta; Mészáros, Peter [Department of Physics, The Pennsylvania State University, University Park, PA 16802 (United States)

    2017-03-20

    X-ray and γ-ray observations by the Swift satellite revealed that a fraction of tidal disruption events (TDEs) have relativistic jets. Jetted TDEs have been considered to be potential sources of very-high-energy cosmic-rays and neutrinos. In this work, using semi-analytical methods, we calculate neutrino spectra of X-ray bright TDEs with powerful jets and dark TDEs with possible choked jets, respectively. We estimate their neutrino fluxes and find that non-detection would give us an upper limit on the baryon loading of the jet luminosity contained in cosmic-rays ξ {sub cr} ≲ 20–50 for Sw J1644+57. We show that X-ray bright TDEs make a sub-dominant (≲5%–10%) contribution to IceCube’s diffuse neutrino flux, and study possible contributions of X-ray dark TDEs given that particles are accelerated in choked jets or disk winds. We discuss future prospects for multi-messenger searches of the brightest TDEs.

  6. A new detector system for low energy X-ray fluorescence coupled with soft X-ray microscopy: First tests and characterization

    Science.gov (United States)

    Gianoncelli, Alessandra; Bufon, Jernej; Ahangarianabhari, Mahdi; Altissimo, Matteo; Bellutti, Pierluigi; Bertuccio, Giuseppe; Borghes, Roberto; Carrato, Sergio; Cautero, Giuseppe; Fabiani, Sergio; Giacomini, Gabriele; Giuressi, Dario; Kourousias, George; Menk, Ralf Hendrik; Picciotto, Antonino; Piemonte, Claudio; Rachevski, Alexandre; Rashevskaya, Irina; Stolfa, Andrea; Vacchi, Andrea; Zampa, Gianluigi; Zampa, Nicola; Zorzi, Nicola

    2016-04-01

    The last decades have witnessed substantial efforts in the development of several detector technologies for X-ray fluorescence (XRF) applications. In spite of the increasing trend towards performing, cost-effective and reliable XRF systems, detectors for soft X-ray spectroscopy still remain a challenge, requiring further study, engineering and customization in order to yield effective and efficient systems. In this paper we report on the development, first characterization and tests of a novel multielement detector system based on low leakage current silicon drift detectors (SDD) coupled to ultra low noise custom CMOS preamplifiers for synchrotron-based low energy XRF. This new system exhibits the potential for improving the count rate by at least an order of magnitude resulting in ten-fold shorter dwell time at an energy resolution similar to that of single element silicon drift detectors.

  7. The Nuclear Spectroscopic Telescope Array (NuSTAR) High-Energy X-ray Mission

    Science.gov (United States)

    Harrison, Fiona A.; Craig, Willliam W.; Christensen, Finn E.; Hailey, Charles J.; Zhang, William W.; Boggs, Steven E.; Stern, Daniel; Cook, W. Rick; Forster, Karl; Giommi, Paolo; hide

    2013-01-01

    High-energy X-ray telescope in orbit. NuSTAR operates in the band from 3 to 79 keV, extending the sensitivity of focusing far beyond the 10 keV high-energy cutoff achieved by all previous X-ray satellites. The inherently low background associated with concentrating the X-ray light enables NuSTAR to probe the hard X-ray sky with a more than 100-fold improvement in sensitivity over the collimated or coded mask instruments that have operated in this bandpass. Using its unprecedented combination of sensitivity and spatial and spectral resolution, NuSTAR will pursue five primary scientific objectives: (1) probe obscured active galactic nucleus (AGN) activity out to thepeak epoch of galaxy assembly in the universe (at z 2) by surveying selected regions of the sky; (2) study the population of hard X-ray-emitting compact objects in the Galaxy by mapping the central regions of the Milky Way; (3) study the non-thermal radiation in young supernova remnants, both the hard X-ray continuum and the emission from the radioactive element 44Ti; (4) observe blazars contemporaneously with ground-based radio, optical, and TeV telescopes, as well as with Fermi and Swift, to constrain the structure of AGN jets; and (5) observe line and continuum emission from core-collapse supernovae in the Local Group, and from nearby Type Ia events, to constrain explosion models. During its baseline two-year mission, NuSTAR will also undertake a broad program of targeted observations. The observatory consists of two co-aligned grazing-incidence X-ray telescopes pointed at celestial targets by a three-axis stabilized spacecraft. Deployed into a 600 km, near-circular, 6 inclination orbit, the observatory has now completed commissioning, and is performing consistent with pre-launch expectations. NuSTAR is now executing its primary science mission, and with an expected orbit lifetime of 10 yr, we anticipate proposing a guest investigator program, to begin in late 2014.

  8. [Neutron Dosimetry System Using CR-39 for High-energy X-ray Radiation Therapy].

    Science.gov (United States)

    Yabuta, Kazutoshi; Monzen, Hajime; Tamura, Masaya; Tsuruta, Takao; Itou, Tetsuo; Nohtomi, Akihiro; Nishimura, Yasumasa

    2014-01-01

    Neutrons are produced during radiation treatment by megavolt X-ray energies. However, it is difficult to measure neutron dose especially just during the irradiation. Therefore, we have developed a system for measuring neutrons with the solid state track detector CR-39, which is free from the influence of the X-ray beams. The energy spectrum of the neutrons was estimated by a Monte Carlo simulation method, and the estimated neutron dose was corrected by the contribution ratio of each energy. Pit formation rates of CR-39 ranged from 2.3 x 10(-3) to 8.2 x 10(-3) for each detector studied. According to the estimated neutron energy spectrum, the energy values for calibration were 144 keV and 515keV, and the contribution ratios were approximately 40:60 for 10 MV photons and 20:70 for photons over 15 MV. Neutron doses measured in the center of a high-energy X-ray field were 0.045 mSv/Gy for a 10 MV linear accelerator and 0.85 mSv/Gy for a 20 MV linear accelerator. We successfully developed the new neutron dose measurement system using the solid track detector, CR-39. This on-time neutron measurement system allows users to measure neutron doses produced in the radiation treatment room more easily.

  9. Novel energy resolving x-ray pinhole camera on Alcator C-Moda)

    Science.gov (United States)

    Pablant, N. A.; Delgado-Aparicio, L.; Bitter, M.; Brandstetter, S.; Eikenberry, E.; Ellis, R.; Hill, K. W.; Hofer, P.; Schneebeli, M.

    2012-10-01

    A new energy resolving x-ray pinhole camera has been recently installed on Alcator C-Mod. This diagnostic is capable of 1D or 2D imaging with a spatial resolution of ≈1 cm, an energy resolution of ≈1 keV in the range of 3.5-15 keV and a maximum time resolution of 5 ms. A novel use of a Pilatus 2 hybrid-pixel x-ray detector [P. Kraft et al., J. Synchrotron Rad. 16, 368 (2009), 10.1107/S0909049509009911] is employed in which the lower energy threshold of individual pixels is adjusted, allowing regions of a single detector to be sensitive to different x-ray energy ranges. Development of this new detector calibration technique was done as a collaboration between PPPL and Dectris Ltd. The calibration procedure is described, and the energy resolution of the detector is characterized. Initial data from this installation on Alcator C-Mod is presented. This diagnostic provides line-integrated measurements of impurity emission which can be used to determine impurity concentrations as well as the electron energy distribution.

  10. Radiation Detection and Dual-Energy X-Ray Imaging for Port Security

    Energy Technology Data Exchange (ETDEWEB)

    Pashby, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Glenn, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Divin, C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Martz, H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-08-09

    Millions of cargo containers are transported across the United States border annually and are inspected for illicit radioactive material and contraband using a combination of passive radiation portal monitors (RPM) and high energy X-ray non-intrusive inspection (NII) systems. As detection performance is expected to vary with the material composition of cargo, characterizing the types of material present in cargo is important to national security. This work analyzes the passive radiation and dual energy radiography signatures from on RPM and two NII system, respectively. First, the cargos were analyzed to determine their ability to attenuate emissions from an embedded radioactive source. Secondly, dual-energy X-ray discrimination was used to determine the material composition and density of the cargos.

  11. New software to model energy dispersive X-ray diffraction in polycrystalline materials

    Energy Technology Data Exchange (ETDEWEB)

    Ghammraoui, B., E-mail: bahaa.ghammraoui@cea.fr [CEA-Leti, MINATEC Campus, 17 rue des Martyrs, F 38054 Grenoble, Cedex 9 (France); Tabary, J. [CEA-Leti, MINATEC Campus, 17 rue des Martyrs, F 38054 Grenoble, Cedex 9 (France); Pouget, S. [CEA-INAC Sciences de la matieres, 17 rue des Martyrs, F 38054 Grenoble, Cedex 9 (France); Paulus, C.; Moulin, V.; Verger, L. [CEA-Leti, MINATEC Campus, 17 rue des Martyrs, F 38054 Grenoble, Cedex 9 (France); Duvauchelle, Ph. [CNDRI-Insa Lyon, Universite de Lyon, F-69621, Villeurbanne Cedex (France)

    2012-02-01

    Detection of illicit materials, such as explosives or drugs, within mixed samples is a major issue, both for general security and as part of forensic analyses. In this paper, we describe a new code simulating energy dispersive X-ray diffraction patterns in polycrystalline materials. This program, SinFullscat, models diffraction of any object in any diffractometer system taking all physical phenomena, including amorphous background, into account. Many system parameters can be tuned: geometry, collimators (slit and cylindrical), sample properties, X-ray source and detector energy resolution. Good agreement between simulations and experimental data was obtained. Simulations using explosive materials indicated that parameters such as the diffraction angle or the energy resolution of the detector have a significant impact on the diffraction signature of the material inspected. This software will be a convenient tool to test many diffractometer configurations, providing information on the one that best restores the spectral diffraction signature of the materials of interest.

  12. Model-based x-ray energy spectrum estimation algorithm from CT scanning data with spectrum filter

    Science.gov (United States)

    Li, Lei; Wang, Lin-Yuan; Yan, Bin

    2016-10-01

    With the development of technology, the traditional X-ray CT can't meet the modern medical and industry needs for component distinguish and identification. This is due to the inconsistency of X-ray imaging system and reconstruction algorithm. In the current CT systems, X-ray spectrum produced by X-ray source is continuous in energy range determined by tube voltage and energy filter, and the attenuation coefficient of object is varied with the X-ray energy. So the distribution of X-ray energy spectrum plays an important role for beam-hardening correction, dual energy CT image reconstruction or dose calculation. However, due to high ill-condition and ill-posed feature of system equations of transmission measurement data, statistical fluctuations of X ray quantum and noise pollution, it is very hard to get stable and accurate spectrum estimation using existing methods. In this paper, a model-based X-ray energy spectrum estimation method from CT scanning data with energy spectrum filter is proposed. First, transmission measurement data were accurately acquired by CT scan and measurement using phantoms with different energy spectrum filter. Second, a physical meaningful X-ray tube spectrum model was established with weighted gaussian functions and priori information such as continuity of bremsstrahlung and specificity of characteristic emission and estimation information of average attenuation coefficient. The parameter in model was optimized to get the best estimation result for filtered spectrum. Finally, the original energy spectrum was reconstructed from filtered spectrum estimation with filter priori information. Experimental results demonstrate that the stability and accuracy of X ray energy spectrum estimation using the proposed method are improved significantly.

  13. Solving atomic structures using statistical mechanical searches on x-ray scattering derived potential energy surfaces

    Science.gov (United States)

    Wright, Christopher James

    Engineering the next generation of materials, especially nanomaterials, requires a detailed understanding of the material's underlying atomic structure. These structures give us better insight into structure-property relationships, allowing for property driven material design on the atomic level. Even more importantly, understanding structures in-situ will translate stimuli and responses on the macroscopic scale to changes on the nanoscale. Despite the importance of precise atomic structures for materials design, solving atomic structures is difficult both experimentally and computationally. Atomic pair distribution functions (PDFs) provide information on atomic structure, but the difficulty of extracting the PDF from x-ray total scattering measurements limits their use. Translating the PDF into an atomic structure requires the search of a very high dimensional space, the set of all potential atomic configurations. The large computational cost of running these simulations also limits the use of PDF as an atomistic probe. This work aims to address these issues by developing 1) novel statistical mechanical approaches to solving material structures, 2) fast simulation of x-ray total scattering and atomic pair distribution functions (PDFs), and 3) data processing procedures for experimental x-ray total scattering measurements. First, experimentally derived potential energy surfaces (PES) and the statistical mechanical ensembles used to search them are developed. Then the mathematical and computational framework for the PDF and its gradients will be discussed. The combined PDF-PES-ensemble system will be benchmarked against a series of nanoparticle structures to ascertain the efficiency and effectiveness of the system. Experimental data processing procedures, which maximize the usable data, will be presented. Finally, preliminary results from experimental x-ray total scattering measurements will be discussed. This work presents one of the most complete end

  14. Forcing Cesium into Higher Oxidation States Using Useful hard x-ray Induced Chemistry under High Pressure

    Energy Technology Data Exchange (ETDEWEB)

    Sneed, D.; Pravica, M.; Kim, E.; Chen, N.; Park, C.; White, M.

    2017-10-01

    This paper discusses our attempt to synthesize higher oxidation forms of cesium fluoride by pressurizing cesium fluoride in a fluorine-rich environment created via the x-ray decomposition of potassium tetrafluoroborate. This was done in order to confirm recent theoretical predictions of higher oxidation forms of CsFn. We discuss the development of a technique to produce molecular fluorine in situ via useful hard x-ray photochemistry, and the attempt to utilize this technique to form higher oxidation states of cesium fluoride. In order to verify the formation of the novel stoichiometric species of CsFn. X-ray Absorption Near Edge Spectroscopy (XANES) centered on the cesium K-edge was performed to probe the oxidation state of cesium as well as the local molecular coordination around Cs.

  15. Measurement of the energy and power radiated by a pulsed blackbody x-ray source.

    Energy Technology Data Exchange (ETDEWEB)

    Chandler, Gordon Andrew; McDaniel, Dillon Heirman; Jorgenson, Roy E.; Warne, Larry Kevin; Dropinski, Steven Clark; Hanson, Donald L.; Johnson, William Arthur; York, Mathew William; Lewis, D.F. (International Specialty Products, Wayne , NJ); Korde, R. (International Radiation Detectors, Torrance, CA); Haslett, C.L. (Ktech Corporation, Albuquerque, NM); Wall, D.L. (Resonetics, Nashua, New hampshire); Ruggles, Laurence E.; Ramirez, L.E. (ATK Mission Research Corporation, Albuquerque, NM); Stygar, William A.; Porter, John Larry, Jr.; McKenney, John Lee; Bryce, Edwin Anthony; Cuneo, Michael Edward; Torres, Jose A.; Mills, Jerry Alan; Leeper, Ramon Joe; McGurn, John Stephen; Fehl, David Lee; Spielman, R. B. (International Specialty Products, Wayne , NJ); Pyle, John H. (Ktech Corporation, Albuquerque, NM); Mazarakis, Michael Gerrassimos; Ives, Harry Crockett, III (EG& G, Albuquerque, NM); Seamen, Johann F.; Simpson, Walter W.

    2006-02-01

    We have developed a diagnostic system that measures the spectrally integrated (i.e. the total) energy and power radiated by a pulsed blackbody x-ray source. The total-energy-and-power (TEP) diagnostic system is optimized for blackbody temperatures between 50 and 350 eV. The system can view apertured sources that radiate energies and powers as high as 2 MJ and 200 TW, respectively, and has been successfully tested at 0.84 MJ and 73 TW on the Z pulsed-power accelerator. The TEP system consists of two pinhole arrays, two silicon-diode detectors, and two thin-film nickel bolometers. Each of the two pinhole arrays is paired with a single silicon diode. Each array consists of a 38 x 38 square array of 10-{micro}m-diameter pinholes in a 50-{micro}m-thick tantalum plate. The arrays achromatically attenuate the x-ray flux by a factor of {approx}1800. The use of such arrays for the attenuation of soft x rays was first proposed by Turner and co-workers [Rev. Sci. Instrum. 70, 656 (1999)RSINAK0034-674810.1063/1.1149385]. The attenuated flux from each array illuminates its associated diode; the diode's output current is recorded by a data-acquisition system with 0.6-ns time resolution. The arrays and diodes are located 19 and 24 m from the source, respectively. Because the diodes are designed to have an approximately flat spectral sensitivity, the output current from each diode is proportional to the x-ray power. The nickel bolometers are fielded at a slightly different angle from the array-diode combinations, and view (without pinhole attenuation) the same x-ray source. The bolometers measure the total x-ray energy radiated by the source and--on every shot--provide an in situ calibration of the array-diode combinations. Two array-diode pairs and two bolometers are fielded to reduce random uncertainties. An analytic model (which accounts for pinhole-diffraction effects) of the sensitivity of an array-diode combination is presented.

  16. Measurement of the energy and power radiated by a pulsed blackbody x-ray source

    Directory of Open Access Journals (Sweden)

    H. C. Ives

    2006-11-01

    Full Text Available We have developed a diagnostic system that measures the spectrally integrated (i.e. the total energy and power radiated by a pulsed blackbody x-ray source. The total-energy-and-power (TEP diagnostic system is optimized for blackbody temperatures between 50 and 350 eV. The system can view apertured sources that radiate energies and powers as high as 2 MJ and 200 TW, respectively, and has been successfully tested at 0.84 MJ and 73 TW on the Z pulsed-power accelerator. The TEP system consists of two pinhole arrays, two silicon-diode detectors, and two thin-film nickel bolometers. Each of the two pinhole arrays is paired with a single silicon diode. Each array consists of a 38×38 square array of 10-μm-diameter pinholes in a 50-μm-thick tantalum plate. The arrays achromatically attenuate the x-ray flux by a factor of ∼1800. The use of such arrays for the attenuation of soft x rays was first proposed by Turner and co-workers [Rev. Sci. Instrum. 70, 656 (1999RSINAK0034-674810.1063/1.1149385]. The attenuated flux from each array illuminates its associated diode; the diode’s output current is recorded by a data-acquisition system with 0.6-ns time resolution. The arrays and diodes are located 19 and 24 m from the source, respectively. Because the diodes are designed to have an approximately flat spectral sensitivity, the output current from each diode is proportional to the x-ray power. The nickel bolometers are fielded at a slightly different angle from the array-diode combinations, and view (without pinhole attenuation the same x-ray source. The bolometers measure the total x-ray energy radiated by the source and—on every shot—provide an in situ calibration of the array-diode combinations. Two array-diode pairs and two bolometers are fielded to reduce random uncertainties. An analytic model (which accounts for pinhole-diffraction effects of the sensitivity of an array-diode combination is presented.

  17. Fast GPU-based absolute intensity determination for energy-dispersive X-ray Laue diffraction

    Science.gov (United States)

    Alghabi, F.; Send, S.; Schipper, U.; Abboud, A.; Pietsch, U.; Kolb, A.

    2016-01-01

    This paper presents a novel method for fast determination of absolute intensities in the sites of Laue spots generated by a tetragonal hen egg-white lysozyme crystal after exposure to white synchrotron radiation during an energy-dispersive X-ray Laue diffraction experiment. The Laue spots are taken by means of an energy-dispersive X-ray 2D pnCCD detector. Current pnCCD detectors have a spatial resolution of 384 × 384 pixels of size 75 × 75 μm2 each and operate at a maximum of 400 Hz. Future devices are going to have higher spatial resolution and frame rates. The proposed method runs on a computer equipped with multiple Graphics Processing Units (GPUs) which provide fast and parallel processing capabilities. Accordingly, our GPU-based algorithm exploits these capabilities to further analyse the Laue spots of the sample. The main contribution of the paper is therefore an alternative algorithm for determining absolute intensities of Laue spots which are themselves computed from a sequence of pnCCD frames. Moreover, a new method for integrating spectral peak intensities and improved background correction, a different way of calculating mean count rate of the background signal and also a new method for n-dimensional Poisson fitting are presented.We present a comparison of the quality of results from the GPU-based algorithm with the quality of results from a prior (base) algorithm running on CPU. This comparison shows that our algorithm is able to produce results with at least the same quality as the base algorithm. Furthermore, the GPU-based algorithm is able to speed up one of the most time-consuming parts of the base algorithm, which is n-dimensional Poisson fitting, by a factor of more than 3. Also, the entire procedure of extracting Laue spots' positions, energies and absolute intensities from a raw dataset of pnCCD frames is accelerated by a factor of more than 3.

  18. Characterization of the Carancas-Puno meteorite by energy dispersive X-ray fluorescence, X-ray diffractometry and transmission Moessbauer spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ceron Loayza, Maria L., E-mail: malucelo@hotmail.com; Bravo Cabrejos, Jorge A. [Universidad Nacional Mayor de San Marcos, Laboratorio de Analisis de Suelos, Facultad de Ciencias Fisicas (Peru)

    2011-11-15

    We report the results of the study of a meteorite that impacted an inhabited zone on 15 September 2007 in the neighborhood of the town of Carancas, Puno Region, about 1,300 km south of Lima. The analysis carried out by energy dispersive X-ray fluorescence, X-ray diffractometry and transmission Moessbauer spectroscopy (at room temperature and at 4.2 K), reveal the presence in the meteorite sample of magnetic sites assigned to taenite (Fe,Ni) and troilite (Fe,S) phases, and of two paramagnetic doublets assigned to Fe{sup 2 + }, one associated with olivine and the other to pyroxene. In accord with these results, this meteorite is classified as a type IV chondrite meteorite.

  19. Characterization of Japanese color sticks by energy dispersive X-ray fluorescence, X-ray diffraction and Fourier transform infrared analysis

    Science.gov (United States)

    Manso, M.; Valadas, S.; Pessanha, S.; Guilherme, A.; Queralt, I.; Candeias, A. E.; Carvalho, M. L.

    2010-04-01

    This work comprises the use of energy dispersive X-ray fluorescence (EDXRF), X-ray diffraction (XRD) and Fourier transformed infrared (FTIR) techniques for the study of the composition of twentieth century traditional Japanese color sticks. By using the combination of analytical techniques it was possible to obtain information on inorganic and organic pigments, binders and fillers present in the sticks. The colorant materials identified in the sticks were zinc and titanium white, chrome yellow, yellow and red ochre, vermillion, alizarin, indigo, Prussian and synthetic ultramarine blue. The results also showed that calcite and barite were used as inorganic mineral fillers while Arabic gum was the medium used. EDXRF offered great potential for such investigations since it allowed the identification of the elements present in the sample preserving its integrity. However, this information alone was not enough to clearly identify some of the materials in study and therefore it was necessary to use XRD and FTIR techniques.

  20. Combination of Raman, infrared, and X-ray energy-dispersion spectroscopies and X-ray d diffraction to study a fossilization process

    Energy Technology Data Exchange (ETDEWEB)

    Sousa Filho, Francisco Eduardo de [Departamento de Fisica, Universidade Regional do Cariri, Crato, CE (Brazil); Joao Herminio da Silva [Universidade Federal do Ceara, Cariri, Juazeiro do Norte, CE (Brazil); Saraiva, Antonio Alamo Feitosa; Brito, Deyvid Dennys S. [Departamento de Ciencias Biologicas, Universidade Regional do Cariri, Crato, CE (Brazil); Viana, Bartolomeu Cruz [Departamento de Fisica, Universidade Federal do Piaui, Teresina, PI, (Brazil); Abagaro, Bruno Tavares de Oliveira; Freire, Paulo de Tarso Cavalcante, E-mail: tarso@fisica.ufc.br [Departamento de Fisica, Universidade Federal do Ceara, Fortaleza, CE (Brazil)

    2011-12-15

    X-ray diffraction was combined with X-ray energy-dispersion, Fourier-transform infrared, and Raman spectroscopies to study the fossilization of a Cretaceous specimen of the plant Brachyphyllum castilhoi, a fossil from the Ipubi Formation, in the Araripe Sedimentary Basin, Northeastern Brazil. Among the possible fossilization processes, which could involve pyrite, silicon oxide, calcium oxide, or other minerals, we were able to single out pyritization as the central mechanism producing the fossil, more than 100 million years ago. In addition to expanding the knowledge of the Ipubi Formation, this study shows that, when combined with other experimental techniques, Raman spectroscopy is a valuable tool at the paleontologist's disposal. (author)

  1. High-energy, high-resolution x-ray imaging for metallic cultural heritages

    Directory of Open Access Journals (Sweden)

    Masato Hoshino

    2017-10-01

    Full Text Available An x-ray micro-imaging technique to visualize high-resolution structure of cultural heritages made of iron or copper has been developed. It utilizes high-energy x-rays from a bending magnet at the SPring-8 synchrotron radiation facility. A white x-ray beam was attenuated by 0.5 mm tungsten and 2.0 mm lead absorbers resulting in the peak energy of 200 keV. The tungsten absorber eliminated the photon energy peak below the absorption edge of lead. A sample was rotated over 180 degrees in 500 s and projection images were continuously collected with an exposure time of 500 ms by an sCMOS camera equipped with a scintillator. Tomographic reconstruction of an ancient sword containing of both copper and iron was successfully obtained at a voxel size of 14.8 μm. Beam hardening was found to cause 2.5 % differences in density in a reconstructed image of a homogeneous stainless-steel rod. Ring artefacts were reduced by continuously moving the absorbers. This work demonstrates feasibility of high-energy, high-resolution imaging at a synchrotron beamline which may be generally useful for inspecting metallic objects.

  2. High-energy, high-resolution x-ray imaging for metallic cultural heritages

    Science.gov (United States)

    Hoshino, Masato; Uesugi, Kentaro; Shikaku, Ryuji; Yagi, Naoto

    2017-10-01

    An x-ray micro-imaging technique to visualize high-resolution structure of cultural heritages made of iron or copper has been developed. It utilizes high-energy x-rays from a bending magnet at the SPring-8 synchrotron radiation facility. A white x-ray beam was attenuated by 0.5 mm tungsten and 2.0 mm lead absorbers resulting in the peak energy of 200 keV. The tungsten absorber eliminated the photon energy peak below the absorption edge of lead. A sample was rotated over 180 degrees in 500 s and projection images were continuously collected with an exposure time of 500 ms by an sCMOS camera equipped with a scintillator. Tomographic reconstruction of an ancient sword containing of both copper and iron was successfully obtained at a voxel size of 14.8 μm. Beam hardening was found to cause 2.5 % differences in density in a reconstructed image of a homogeneous stainless-steel rod. Ring artefacts were reduced by continuously moving the absorbers. This work demonstrates feasibility of high-energy, high-resolution imaging at a synchrotron beamline which may be generally useful for inspecting metallic objects.

  3. A wavelet-based Gaussian method for energy dispersive X-ray fluorescence spectrum

    Directory of Open Access Journals (Sweden)

    Pan Liu

    2017-05-01

    Full Text Available This paper presents a wavelet-based Gaussian method (WGM for the peak intensity estimation of energy dispersive X-ray fluorescence (EDXRF. The relationship between the parameters of Gaussian curve and the wavelet coefficients of Gaussian peak point is firstly established based on the Mexican hat wavelet. It is found that the Gaussian parameters can be accurately calculated by any two wavelet coefficients at the peak point which has to be known. This fact leads to a local Gaussian estimation method for spectral peaks, which estimates the Gaussian parameters based on the detail wavelet coefficients of Gaussian peak point. The proposed method is tested via simulated and measured spectra from an energy X-ray spectrometer, and compared with some existing methods. The results prove that the proposed method can directly estimate the peak intensity of EDXRF free from the background information, and also effectively distinguish overlap peaks in EDXRF spectrum.

  4. Electron cyclotron resonance ion source plasma characterization by energy dispersive x-ray imaging

    Science.gov (United States)

    Rácz, R.; Mascali, D.; Biri, S.; Caliri, C.; Castro, G.; Galatà, A.; Gammino, S.; Neri, L.; Pálinkás, J.; Romano, F. P.; Torrisi, G.

    2017-07-01

    Pinhole and CCD based quasi-optical x-ray imaging technique was applied to investigate the plasma of an electron cyclotron resonance ion source (ECRIS). Spectrally integrated and energy resolved images were taken from an axial perspective. The comparison of integrated images taken of argon plasma highlights the structural changes affected by some ECRIS setting parameters, like strength of the axial magnetic confinement, RF frequency and microwave power. Photon counting analysis gives precise intensity distribution of the x-ray emitted by the argon plasma and by the plasma chamber walls. This advanced technique points out that the spatial positions of the electron losses are strongly determined by the kinetic energy of the electrons themselves to be lost and also shows evidences how strongly the plasma distribution is affected by slight changes in the RF frequency.

  5. Structured photocathodes for improved high-energy x-ray efficiency in streak cameras

    Energy Technology Data Exchange (ETDEWEB)

    Opachich, Y. P., E-mail: opachiyp@nv.doe.gov; Huffman, E.; Koch, J. A. [National Security Technologies, LLC, Livermore, California 94551 (United States); Bell, P. M.; Bradley, D. K.; Hatch, B.; Landen, O. L.; MacPhee, A. G.; Nagel, S. R. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Chen, N.; Gopal, A.; Udin, S. [Nanoshift LLC, Emeryville, California 94608 (United States); Feng, J. [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Hilsabeck, T. J. [General Atomics, San Diego, California 92121 (United States)

    2016-11-15

    We have designed and fabricated a structured streak camera photocathode to provide enhanced efficiency for high energy X-rays (1–12 keV). This gold coated photocathode was tested in a streak camera and compared side by side against a conventional flat thin film photocathode. Results show that the measured electron yield enhancement at energies ranging from 1 to 10 keV scales well with predictions, and that the total enhancement can be more than 3×. The spatial resolution of the streak camera does not show degradation in the structured region. We predict that the temporal resolution of the detector will also not be affected as it is currently dominated by the slit width. This demonstration with Au motivates exploration of comparable enhancements with CsI and may revolutionize X-ray streak camera photocathode design.

  6. Study of heavy metals and other elements in macrophyte algae using energy-dispersive X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, M.L.; Amorim, P.; Marques, M.I.M.; Ramos, M.T. [Univ. de Lisboa (Portugal); Ferreira, J.G. [Faculdade de Ciencias e Tecnologia, Monte de Caparica (Portugal). Dept. Ciencias e Engenharia do Ambiente

    1997-04-01

    Fucus vesiculosus L. seaweeds from three estuarine stations were analyzed by X-ray fluorescence, providing results for the concentration of total K, Ca, Ti, Mn, Fe, Co, Ni, Cu, Zn, As, Br, Sr, and Pb. Four different structures of the algae (base, stipe, reproductive organs, and growing tips) were analyzed to study the differential accumulation of heavy metals by different parts of Fucus. Some elements (e.g., Cu and Fe) are preferentially accumulated in the base of the algae, whereas others (e.g., As) exhibit higher concentrations in the reproductive organs and growing tips. The pattern of accumulation in different structures is similar for Cu, Zn, and Pb, but for other metals there is considerable variability in accumulation between parts of the plant. This is important in determining which structures of the plant should be used for biomonitoring. For samples collected at stations subject to differing metal loads, the relative elemental composition is approximately constant, notwithstanding significant variation in absolute values. The proportion of metals in Fucus is similar to that found in other estuaries, where metal concentrations are significantly lower. Energy-dispersive X-ray fluorescence has been shown to be a suitable technique for multielement analysis in this type of sample. No chemical pretreatment is required, minimizing sample contamination. The small amount of sample required, and the wide range of elements that can be detected simultaneously make energy-dispersive X-ray fluorescence a valuable tool for pollution studies.

  7. Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging

    Science.gov (United States)

    Iwanczyk, Jan S.; Nygård, Einar; Meirav, Oded; Arenson, Jerry; Barber, William C.; Hartsough, Neal E.; Malakhov, Nail; Wessel, Jan C.

    2009-01-01

    The development of an innovative detector technology for photon-counting in X-ray imaging is reported. This new generation of detectors, based on pixellated cadmium telluride (CdTe) and cadmium zinc telluride (CZT) detector arrays electrically connected to application specific integrated circuits (ASICs) for readout, will produce fast and highly efficient photon-counting and energy-dispersive X-ray imaging. There are a number of applications that can greatly benefit from these novel imagers including mammography, planar radiography, and computed tomography (CT). Systems based on this new detector technology can provide compositional analysis of tissue through spectroscopic X-ray imaging, significantly improve overall image quality, and may significantly reduce X-ray dose to the patient. A very high X-ray flux is utilized in many of these applications. For example, CT scanners can produce ~100 Mphotons/mm2/s in the unattenuated beam. High flux is required in order to collect sufficient photon statistics in the measurement of the transmitted flux (attenuated beam) during the very short time frame of a CT scan. This high count rate combined with a need for high detection efficiency requires the development of detector structures that can provide a response signal much faster than the transit time of carriers over the whole detector thickness. We have developed CdTe and CZT detector array structures which are 3 mm thick with 16×16 pixels and a 1 mm pixel pitch. These structures, in the two different implementations presented here, utilize either a small pixel effect or a drift phenomenon. An energy resolution of 4.75% at 122 keV has been obtained with a 30 ns peaking time using discrete electronics and a 57Co source. An output rate of 6×106 counts per second per individual pixel has been obtained with our ASIC readout electronics and a clinical CT X-ray tube. Additionally, the first clinical CT images, taken with several of our prototype photon-counting and energy

  8. Body composition in hemodialysis patients measured by dual-energy X-ray absorptiometry

    DEFF Research Database (Denmark)

    Stenver, Doris Irene; Gotfredsen, Arne; Hilsted, J

    1995-01-01

    Dual-energy X-ray absorptiometry (DXA) measures three of the principal components of the body: fat mass, lean soft-tissue mass (comprising muscle, inner organs, and the body water), and the bone mineral content. The purpose of this study was to test the estimation capacity of DXA when it is applied...... that DXA is a useful tool for estimating the magnitude of body compartments in patients with end-stage renal failure....

  9. Energy dispersive x-ray spectroscopy for nanostructured thin film density evaluation

    OpenAIRE

    Prencipe, Irene; Dellasega, David; Zani, Alessandro; Rizzo, Daniele; Passoni, Matteo

    2015-01-01

    In this paper, we report on two fast and non-destructive methods for nanostructured film density evaluation based on a combination of energy dispersive x-ray spectroscopy for areal density measurement and scanning electron microscopy (SEM) for thickness evaluation. These techniques have been applied to films with density ranging from the density of a solid down to a few , with different compositions and morphologies. The high resolution of an electron microprobe has been exploited to characte...

  10. Targeted Silver Nanoparticles for Dual-Energy Breast X-Ray Imaging

    Science.gov (United States)

    2013-03-01

    the applicability of AgNP as contrast agents for use in DE-CE digital breast tomosynthesis and digital mammography . Three objectives have been...silver (Ag) nanoparticle (NP) contrast agent optimized for dual- energy (DE) contrast -enhanced (CE) breast x-ray imaging. CE digital breast imaging...provides an accurate method for decomposition of images into distinct breast tissue and contrast agent signals. At present, DE-CE breast imaging is

  11. Modular soft x-ray spectrometer for applications in energy sciences and quantum materials

    Science.gov (United States)

    Chuang, Yi-De; Shao, Yu-Cheng; Cruz, Alejandro; Hanzel, Kelly; Brown, Adam; Frano, Alex; Qiao, Ruimin; Smith, Brian; Domning, Edward; Huang, Shih-Wen; Wray, L. Andrew; Lee, Wei-Sheng; Shen, Zhi-Xun; Devereaux, Thomas P.; Chiou, Jaw-Wern; Pong, Way-Faung; Yashchuk, Valeriy V.; Gullikson, Eric; Reininger, Ruben; Yang, Wanli; Guo, Jinghua; Duarte, Robert; Hussain, Zahid

    2017-01-01

    Over the past decade, the advances in grating-based soft X-ray spectrometers have revolutionized the soft X-ray spectroscopies in materials research. However, these novel spectrometers are mostly dedicated designs, which cannot be easily adopted for applications with diverging demands. Here we present a versatile spectrometer design concept based on the Hettrick-Underwood optical scheme that uses modular mechanical components. The spectrometer's optics chamber can be used with gratings operated in either inside or outside orders, and the detector assembly can be reconfigured accordingly. The spectrometer can be designed to have high spectral resolution, exceeding 10 000 resolving power when using small source (˜1 μ m) and detector pixels (˜5 μ m) with high line density gratings (˜3000 lines/mm), or high throughput at moderate resolution. We report two such spectrometers with slightly different design goals and optical parameters in this paper. We show that the spectrometer with high throughput and large energy window is particularly useful for studying the sustainable energy materials. We demonstrate that the extensive resonant inelastic X-ray scattering (RIXS) map of battery cathode material LiNi1/3Co1/3Mn1/3O2 can be produced in few hours using such a spectrometer. Unlike analyzing only a handful of RIXS spectra taken at selected excitation photon energies across the elemental absorption edges to determine various spectral features like the localized dd excitations and non-resonant fluorescence emissions, these features can be easily identified in the RIXS maps. Studying such RIXS maps could reveal novel transition metal redox in battery compounds that are sometimes hard to be unambiguously identified in X-ray absorption and emission spectra. We propose that this modular spectrometer design can serve as the platform for further customization to meet specific scientific demands.

  12. An InGrid based Low Energy X-ray Detector

    CERN Document Server

    Krieger, Christoph; Kaminski, Jochen; Lupberger, Michael; Vafeiadis, Theodoros

    2014-01-01

    An X-ray detector based on the combination of an integrated Micromegas stage with a pixel chip has been built in order to be installed at the CERN Axion Solar Telescope. Due to its high granularity and spatial resolution this detector allows for a topological background suppression along with a detection threshold below $1\\,\\text{keV}$. Tests at the CAST Detector Lab show the detector's ability to detect X-ray photons down to an energy as low as $277\\,\\text{eV}$. The first background data taken after the installation at the CAST experiment underline the detector's performance with an average background rate of $5\\times10^{-5}\\,/\\text{keV}/\\text{cm}^2/\\text{s}$ between 2 and $10\\,\\text{keV}$ when using a lead shielding.

  13. High energy X-ray photon counting imaging using linear accelerator and silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Y., E-mail: cycjty@sophie.q.t.u-tokyo.ac.jp [Department of Bioengineering, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Shimazoe, K.; Yan, X. [Department of Nuclear Engineering and Management, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Ueda, O.; Ishikura, T. [Fuji Electric Co., Ltd., Fuji, Hino, Tokyo 191-8502 (Japan); Fujiwara, T. [National Institute of Advanced Industrial Science and Technology, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Uesaka, M.; Ohno, M. [Nuclear Professional School, the University of Tokyo, 2-22 Shirakata-shirane, Tokai, Ibaraki 319-1188 (Japan); Tomita, H. [Department of Quantum Engineering, Nagoya University, Furo, Chikusa, Nagoya 464-8603 (Japan); Yoshihara, Y. [Department of Nuclear Engineering and Management, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Takahashi, H. [Department of Bioengineering, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Department of Nuclear Engineering and Management, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)

    2016-09-11

    A photon counting imaging detector system for high energy X-rays is developed for on-site non-destructive testing of thick objects. One-dimensional silicon strip (1 mm pitch) detectors are stacked to form a two-dimensional edge-on module. Each detector is connected to a 48-channel application specific integrated circuit (ASIC). The threshold-triggered events are recorded by a field programmable gate array based counter in each channel. The detector prototype is tested using 950 kV linear accelerator X-rays. The fast CR shaper (300 ns pulse width) of the ASIC makes it possible to deal with the high instant count rate during the 2 μs beam pulse. The preliminary imaging results of several metal and concrete samples are demonstrated.

  14. Fast scattering simulation tool for multi-energy x-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sossin, A., E-mail: artur.sossin@cea.fr [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France); Tabary, J.; Rebuffel, V. [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France); Létang, J.M.; Freud, N. [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Claude Bernard Lyon 1, Centre Léon Bérard (France); Verger, L. [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France)

    2015-12-01

    A combination of Monte Carlo (MC) and deterministic approaches was employed as a means of creating a simulation tool capable of providing energy resolved x-ray primary and scatter images within a reasonable time interval. Libraries of Sindbad, a previously developed x-ray simulation software, were used in the development. The scatter simulation capabilities of the tool were validated through simulation with the aid of GATE and through experimentation by using a spectrometric CdTe detector. A simple cylindrical phantom with cavities and an aluminum insert was used. Cross-validation with GATE showed good agreement with a global spatial error of 1.5% and a maximum scatter spectrum error of around 6%. Experimental validation also supported the accuracy of the simulations obtained from the developed software with a global spatial error of 1.8% and a maximum error of around 8.5% in the scatter spectra.

  15. Co marker determination in rumen liquid sample by energy dispersive X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Eduardo de; Nascimento Filho, Virgilio F.; Massoni, Paulo R. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Instrumentacao Nuclear (LIN)]. E-mail: edualm@usp.br; Leite, Laudi C.; Lanna, Dante P.D. [Escola Superior de Agricultura ' Luiz de Queiroz' (ESALQ/USP), Piracicaba, SP (Brazil). Dept. de Zootecnia. Lab. de Anatomia e Fisiologia Animal (LAFA)]. E-mail: lcleite@ciagri.usp.br

    2007-07-01

    The Co element is used in nutritional studies as marker. This paper describes an analytical methodology for Co determination in rumen liquid sample using energy dispersive X-ray spectrometry (EDXRF). 200 {mu}L of the sample were dried at 60 deg C on 6.35 {mu}m Mylar film. Ga was used as internal standard. The excitation was carried out utilizing Mo target X-ray tube (Zr filter) at 30 kV / 20 mA. The acquisition time was 200 s. The accuracy of this methodology was assessed through standard addition method, the recovery obtained was 98.7 % for Co. The detection limit was 0.15 mg / L for this element. (author)

  16. Lead iodide films as X-ray sensors tested in the mammography energy region

    Energy Technology Data Exchange (ETDEWEB)

    Condeles, J.F. [Departamento de Fisica e Matematica, Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto, Universidade de Sao Paulo, Av. Bandeirantes 3900, 14040-901 Ribeirao Preto, SP (Brazil)]. E-mail: fernando_condeles@pg.ffclrp.usp.br; Ghilardi Netto, T. [Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto, Universidade de Sao Paulo, Av. Bandeirantes 3900, 14048-900 Ribeirao Preto, SP (Brazil); Mulato, M. [Departamento de Fisica e Matematica, Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto, Universidade de Sao Paulo, Av. Bandeirantes 3900, 14040-901 Ribeirao Preto, SP (Brazil)

    2007-07-11

    We present an alternative method for the deposition of thin films of lead iodide (PbI{sub 2}), which is a promising semiconductor candidate for applications in medical digital radiography. The spray pyrolysis technique enables the fabrication of thick films with a deposition rate of about 3.3 As{sup -1}. We investigate the influence of the main deposition parameters on the final properties of the films. They were substrate temperature from 150 up to 270 {sup o}C and nozzle-spray distance to substrate from 13.0 to 16.5 cm. The films were mainly investigated using X-ray diffraction (XRD), Atomic Force Microscopy (AFM), and Photoluminescence (PL) spectroscopy. Also, electrical characterizations were made in the dark as a function of temperature, and with the samples submitted to X-ray exposures in the energy range of mammography diagnosis.

  17. Crystallographic Characterization of Extraterrestrial Materials by Energy-Scanning X-ray Diffraction

    Science.gov (United States)

    Hagiya, Kenji; Mikouchi, Takashi; Ohsumi, Kazumasa; Terada, Yasuko; Yagi, Naoto; Komatsu, Mutsumi; Yamaguchi, Shoki; Hirata, Arashi; Kurokawa, Ayaka; Zolensky, Michael E. (Principal Investigator)

    2016-01-01

    We have continued our long-term project using X-ray diffraction to characterize a wide range of extraterrestrial samples. The stationary sample method with polychromatic X-rays is advantageous because the irradiated area of the sample is always same and fixed, meaning that all diffraction spots occur from the same area of the sample, however, unit cell parameters cannot be directly obtained by this method though they are very important for identification of mineral and for determination of crystal structures. In order to obtain the cell parameters even in the case of the sample stationary method, we apply energy scanning of a micro-beam of monochromatic SR at SPring-8.

  18. Radiological safety of food irradiation with high energy X-rays: theoretical expectations and experimental evidence

    Energy Technology Data Exchange (ETDEWEB)

    Gregoire, O. E-mail: olivier.gregoire@iba.be; Cleland, M.R.; Mittendorfer, J.; Dababneh, S.; Ehlermann, D.A.E.; Fan, X.; Kaeppeler, F.; Logar, J.; Meissner, J.; Mullier, B.; Stichelbaut, F.; Thayer, D.W

    2003-06-01

    The radiological safety of red meat irradiated with 7.5 MeV X-rays (bremsstrahlung) has been investigated theoretically and verified by dedicated experiments. Samples of meat and meat ash were located in a large volume of fresh meat at the position of the highest photoneutron fluence and irradiated to an X-ray dose of 15 kGy, twice the maximum dose allowed by the US FDA for meat irradiation. In order to evaluate the safety of treatment with any kind of electron accelerators, two experiments have been performed with different accelerators delivering electrons with a narrow and a broad energy spread. The measured activities and theoretical estimates are of the same order of magnitude. An evaluation of the corresponding radiation exposure from ingestion of the irradiated product has been compared to natural background radiation. The paper concludes that the risk to individuals from intake of food irradiated with X-rays from 7.5 MeV electrons, even with a broad energy spectrum, would be trivial.

  19. High-energy x-ray grating-based phase-contrast radiography of human anatomy

    Science.gov (United States)

    Horn, Florian; Hauke, Christian; Lachner, Sebastian; Ludwig, Veronika; Pelzer, Georg; Rieger, Jens; Schuster, Max; Seifert, Maria; Wandner, Johannes; Wolf, Andreas; Michel, Thilo; Anton, Gisela

    2016-03-01

    X-ray grating-based phase-contrast Talbot-Lau interferometry is a promising imaging technology that has the potential to raise soft tissue contrast in comparison to conventional attenuation-based imaging. Additionally, it is sensitive to attenuation, refraction and scattering of the radiation and thus provides complementary and otherwise inaccessible information due to the dark-field image, which shows the sub-pixel size granularity of the measured object. Until recent progress the method has been mainly limited to photon energies below 40 keV. Scaling the method to photon energies that are sufficient to pass large and spacious objects represents a challenging task. This is caused by increasing demands regarding the fabrication process of the gratings and the broad spectra that come along with the use of polychromatic X-ray sources operated at high acceleration voltages. We designed a setup that is capable to reach high visibilities in the range from 50 to 120 kV. Therefore, spacious and dense parts of the human body with high attenuation can be measured, such as a human knee. The authors will show investigations on the resulting attenuation, differential phase-contrast and dark-field images. The images experimentally show that X-ray grating-based phase-contrast radiography is feasible with highly absorbing parts of the human body containing massive bones.

  20. Design of dual energy x-ray detector for conveyor belt with steel wire ropes

    Science.gov (United States)

    Dai, Yue; Miao, Changyun; Rong, Feng

    2009-07-01

    A dual energy X-ray detector for conveyor belt with steel wire ropes is researched in the paper. Conveyor belt with steel wire ropes is one of primary transfer equipments in modern production. The traditional test methods like electromagnetic induction principle could not display inner image of steel wire ropes directly. So X-ray detection technology has used to detect the conveyor belt. However the image was not so clear by the interference of the rubber belt. Therefore, the dualenergy X-ray detection technology with subtraction method is developed to numerically remove the rubber belt from radiograph, thus improving the definition of the ropes image. The purpose of this research is to design a dual energy Xray detector that could make the operator easier to found the faulty of the belt. This detection system is composed of Xray source, detector controlled by FPGA chip, PC for running image processing system and so on. With the result of the simulating, this design really improved the capability of the staff to test the conveyor belt.

  1. Dosimetric evaluation of Rhizophora spp. binderless particleboard phantom for diagnostic X-ray energy

    Science.gov (United States)

    Marashdeh, M. W.; Tajuddin, A. A.; Bauk, S.; Hashim, R.

    2017-07-01

    This research aims to evaluate the suitability of using binderless particleboard made from Rhizophora spp. mangrove wood as a dosimetric phantom for X-ray in the diagnostic energy regions. Comparative measurements of percentage depth and surface doses in Rhizophora spp. binderless particleboard phantom and similarly shaped Perspex and water phantoms were performed. Measurements were conducted in the diagnostic X-ray energy range of 50 kVp to 90 kVp. Results showed that the binderless particleboard phantom can be used for dosimetric measurements. For the X-ray beam at 90 kVp, the binderless particleboard and water phantom showed data agreement of 1.6%, 2.7%, and 4.3% at depths of 1, 2, and 4 cm, respectively, whereas the measurements in water and Perspex were 1.8%, 2.7%, and 4.4%. The surface dose differences were due to difference in the backscattering material. The doses measured at the surface were within 0.4% for binderless particleboard and water and within 0.9% for Perspex and water.

  2. Hard X-ray bremsstrahlung production in solar flares by high-energy proton beams

    Science.gov (United States)

    Emslie, A. G.; Brown, J. C.

    1985-01-01

    The possibility that solar hard X-ray bremsstrahlung is produced by acceleration of stationary electrons by fast-moving protons, rather than vice versa, as commonly assumed, was investigated. It was found that a beam of protons which involves 1836 times fewer particles, each having an energy 1836 times greater than that of the electrons in the equivalent electron beam model, has exactly the same bremsstrahlung yield for a given target, i.e., the mechanism has an energetic efficiency equal to that of conventional bremsstrahlung models. Allowance for the different degrees of target ionization appropriate to the two models (for conventional flare geometries) makes the proton beam model more efficient than the electron beam model, by a factor of order three. The model places less stringent constraints than a conventional electron beam model on the flare energy release mechanism. It is also consistent with observed X-ray burst spectra, intensities, and directivities. The altitude distribution of hard X-rays predicted by the model agrees with observations only if nonvertical injection of the protons is assumed. The model is inconsistent with gamma-ray data in terms of conventional modeling.

  3. Topics in High-Energy Astrophysics: X-ray Time Lags and Gamma-ray Flares

    Science.gov (United States)

    Kroon, John J.

    2016-03-01

    The Universe is host to a wide variety of high-energy processes that convert gravitational potential energy or rest-mass energy into non-thermal radiation such as bremsstrahlung and synchrotron. Prevailing models of X-ray emission from accreting Black Hole Binaries (BHBs) struggle to simultaneously fit the quiescent X-ray spectrum and the transients which result in the phenomenon known as X-ray time lags. And similarly, classical models of diffusive shock acceleration in pulsar wind nebulae fail to explain the extreme particle acceleration in very short timescales as is inferred from recent gamma-ray flares from the Crab nebula. In this dissertation, I develop new exact analytic models to shed light on these intriguing processes. I take a fresh look at the formation of X-ray time lags in compact sources using a new mathematical approach in which I obtain the exact Green's function solution. The resulting Green's function allows one to explore a variety of injection scenarios, including both monochromatic and broadband (bremsstrahlung) seed photon injection. I obtain the exact solution for the dependence of the time lags on the Fourier frequency, for both homogeneous and inhomogeneous clouds. The model can successfully reproduce both the observed time lags and the quiescent X-ray spectrum using a single set of coronal parameters. I show that the implied coronal radii in the new model are significantly smaller than those obtained in the Monte Carlo simulations, hence greatly reducing the coronal heating problem. Recent bright gamma-ray flares from the Crab nebula observed by AGILE and Fermi reaching GeV energies and lasting several days challenge the contemporary model for particle acceleration in pulsar wind nebulae, specifically the diffusive shock acceleration model. Simulations indicate electron/positron pairs in the Crab nebula pulsar wind must be accelerated up to PeV energies in the presence of ambient magnetic fields with strength B ~100 microG. No

  4. Is scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS) quantitative?

    Science.gov (United States)

    Newbury, Dale E; Ritchie, Nicholas W M

    2013-01-01

    Scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS) is a widely applied elemental microanalysis method capable of identifying and quantifying all elements in the periodic table except H, He, and Li. By following the "k-ratio" (unknown/standard) measurement protocol development for electron-excited wavelength dispersive spectrometry (WDS), SEM/EDS can achieve accuracy and precision equivalent to WDS and at substantially lower electron dose, even when severe X-ray peak overlaps occur, provided sufficient counts are recorded. Achieving this level of performance is now much more practical with the advent of the high-throughput silicon drift detector energy dispersive X-ray spectrometer (SDD-EDS). However, three measurement issues continue to diminish the impact of SEM/EDS: (1) In the qualitative analysis (i.e., element identification) that must precede quantitative analysis, at least some current and many legacy software systems are vulnerable to occasional misidentification of major constituent peaks, with the frequency of misidentifications rising significantly for minor and trace constituents. (2) The use of standardless analysis, which is subject to much broader systematic errors, leads to quantitative results that, while useful, do not have sufficient accuracy to solve critical problems, e.g. determining the formula of a compound. (3) EDS spectrometers have such a large volume of acceptance that apparently credible spectra can be obtained from specimens with complex topography that introduce uncontrolled geometric factors that modify X-ray generation and propagation, resulting in very large systematic errors, often a factor of ten or more. © Wiley Periodicals, Inc.

  5. Automated materials discrimination using 3D dual energy X ray images

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ta Wee

    2002-07-01

    The ability of a human observer to identify an explosive device concealed in complex arrangements of objects routinely encountered in the 2D x-ray screening of passenger baggage at airports is often problematic. Standard dual-energy x-ray techniques enable colour encoding of the resultant images in terms of organic, inorganic and metal substances. This transmission imaging technique produces colour information computed from a high-energy x-ray signal and a low energy x-ray signal (80keVenergy x-ray machine previously developed by the Vision Systems Group at The Nottingham Trent University in collaboration with The Home Office Science and Technology Group provided the image data for the empirical investigation. This machine utilises a novel linear castellated dual-energy x-ray detector recently developed by the Vision Systems Group. This detector array employs half the number of scintillator-photodiode sensors in comparison to a conventional linear dual-energy sensor

  6. X-ray spectrometer having 12 000 resolving power at 8 keV energy

    Science.gov (United States)

    Seely, John F.; Hudson, Lawrence T.; Henins, Albert; Feldman, Uri

    2017-10-01

    An x-ray spectrometer employing a thin (50 μm) silicon transmission crystal was used to record high-resolution Cu Kα spectra from a laboratory x-ray source. The diffraction was from the (331) planes that were at an angle of 13.26° to the crystal surface. The components of the spectral lines resulting from single-vacancy (1s) and double-vacancy (1s and 3d) transitions were observed. After accounting for the natural lifetime widths from reference double-crystal spectra and the spatial resolution of the image plate detector, the intrinsic broadening of the transmission crystal was measured to be as small as 0.67 eV and the resolving power 12 000, the highest resolving power achieved by a compact (0.5 m long) spectrometer employing a single transmission crystal operating in the hard x-ray region. By recording spectra with variable source-to-crystal distances and comparing to the calculated widths from various geometrical broadening mechanisms, the primary contributions to the intrinsic crystal broadening were found to be the source height at small distances and the crystal apertured height at large distances. By reducing these two effects, using a smaller source size and vignetting the crystal height, the intrinsic crystal broadening is then limited by the crystal thickness and the rocking curve width and would be 0.4 eV at 8 keV energy (20 000 resolving power).

  7. X-ray spectroscopy for chemical and energy sciences: the case of heterogeneous catalysis.

    Science.gov (United States)

    Frenkel, Anatoly I; van Bokhoven, Jeroen A

    2014-09-01

    Heterogeneous catalysis is the enabling technology for much of the current and future processes relevant for energy conversion and chemicals synthesis. The development of new materials and processes is greatly helped by the understanding of the catalytic process at the molecular level on the macro/micro-kinetic time scale and on that of the actual bond breaking and bond making. The performance of heterogeneous catalysts is inherently the average over the ensemble of active sites. Much development aims at unravelling the structure of the active site; however, in general, these methods yield the ensemble-average structure. A benefit of X-ray-based methods is the large penetration depth of the X-rays, enabling in situ and operando measurements. The potential of X-ray absorption and emission spectroscopy methods (XANES, EXAFS, HERFD, RIXS and HEROS) to directly measure the structure of the catalytically active site at the single nanoparticle level using nanometer beams at diffraction-limited storage ring sources is highlighted. The use of pump-probe schemes coupled with single-shot experiments will extend the time range from the micro/macro-kinetic time domain to the time scale of bond breaking and making.

  8. [Application of in situ micro energy dispersive X-ray fluorescence analysis in mineralogy].

    Science.gov (United States)

    Yang, Hai; Ge, Liang-Quan; Gu, Yi; Zhang, Qing-Xian; Xiong, Sheng-Qing

    2013-11-01

    Thirteen rock samples were collected for studying the variation of element content in the mineral during the alteration process from Xinjiang, China. The IED-6000 in situ micro energy dispersive X-ray fluorescence developed by CDUT was applied to get chemical and physical data from minerals. The non-destructive spectrometer is based on a low-power Mo-anode X-ray tube and a Si-PIN peltier cooled X-ray detector. The unique design of the tube's probe allows very close coupling of polycapillary and makes the use of micro-area measurement feasible and efficient. The spectrometer can be integrated into any microscope for analysis. The long axis diameter of beam spot is about 110 microm. According to micro-EDXRF measurement, the tetrahedrite was corrected to pyrite, improving the efficiency and accuracy of the mineral identification. The feldspar of mineralized rock sample is rich in Cu and Zn which can be used as prospecting indicator elements. Element content of Cr, Mn and Co shows negative correlation with the degree of mineralization.

  9. Effects of synchrotron radiation spectrum energy on polymethyl methacrylate photosensitivity to deep x-ray lithography

    CERN Document Server

    Mekaru, H; Hattori, T

    2003-01-01

    Since X-ray lithography requires a high photon flux to achieve deep resist exposure, a synchrotron radiation beam, which is not monochromatized, is generally used as a light source. If the synchrotron radiation beam is monochromatized, photon flux will decrease rapidly. Because of this reason, the wavelength dependence of the resist sensitivity has not been investigated for deep X-ray lithography. Measuring the spectrum of a white beam with a Si solid-state detector (SSD) is difficult because a white beam has a high intensity and an SSD has a high sensitivity. We were able to measure the spectrum and the photocurrent of a white beam from a beam line used for deep X-ray lithography by keeping the ring current below 0.05 mA. We evaluated the characteristics of the output beam based on the measured spectrum and photocurrent, and used them to investigate the relationship between the total exposure energy and the dose-processing depth with polymethyl methacrylate (PMMA). We found that it is possible to guess the p...

  10. The UCSD high energy X-ray timing experiment cosmic ray particle anticoincidence detector

    Science.gov (United States)

    Hink, P. L.; Rothschild, R. E.; Pelling, M. R.; Macdonald, D. R.; Gruber, D. E.

    1991-01-01

    The HEXTE, part of the X-Ray Timing Explorer (XTE), is designed to make high sensitivity temporal and spectral measurements of X-rays with energies between 15 and 250 keV using NaI/CsI phoswich scintillation counters. To achieve the required sensitivity it is necessary to provide anticoincidence of charged cosmic ray particles incident upon the instrument, some of which interact to produce background X-rays. The proposed cosmic ray particle anticoincidence shield detector for HEXTE uses a novel design based on plastic scintillators and wavelength-shifter bars. It consists of five segments, each with a 7 mm thick plastic scintillator, roughly 50 cm x 50 cm in size, coupled to two wavelength-shifter bars viewed by 1/2 inch photomultiplier tubes. These segments are configured into a five-sided, box-like structure around the main detector system. Results of laboratory testing of a model segment, and calculations of the expected performance of the flight segments and particle anticoincidence detector system are presented to demonstrate that the above anticoincidence detector system satisfies its scientific requirements.

  11. A Spectrometer for X-Ray Energy-Dispersive Diffraction using Synchrotron Radiation

    DEFF Research Database (Denmark)

    Staun Olsen, Janus; Buras, B; Gerward, Leif

    1981-01-01

    Describes a white-beam X-ray energy-dispersive diffractometer built for Hasylab in Hamburg, FRG, using the synchrotron radiation from the electron storage ring DORIS. The following features of the instrument are discussed: horizontal or vertical scattering plane, collimators, sample environment......, remote control of the goniometer, data acquisition, energy-sensitive detectors using small-area and large-area detector crystals, modes of operation, powder and single crystal diffraction. An example is given from a high-pressure study of YbH2 using a diamond anvil cell....

  12. Ground state potential energy surfaces around selected atoms from resonant inelastic x-ray scattering.

    Science.gov (United States)

    Schreck, Simon; Pietzsch, Annette; Kennedy, Brian; Såthe, Conny; Miedema, Piter S; Techert, Simone; Strocov, Vladimir N; Schmitt, Thorsten; Hennies, Franz; Rubensson, Jan-Erik; Föhlisch, Alexander

    2016-01-29

    Thermally driven chemistry as well as materials' functionality are determined by the potential energy surface of a systems electronic ground state. This makes the potential energy surface a central and powerful concept in physics, chemistry and materials science. However, direct experimental access to the potential energy surface locally around atomic centers and to its long-range structure are lacking. Here we demonstrate how sub-natural linewidth resonant inelastic soft x-ray scattering at vibrational resolution is utilized to determine ground state potential energy surfaces locally and detect long-range changes of the potentials that are driven by local modifications. We show how the general concept is applicable not only to small isolated molecules such as O2 but also to strongly interacting systems such as the hydrogen bond network in liquid water. The weak perturbation to the potential energy surface through hydrogen bonding is observed as a trend towards softening of the ground state potential around the coordinating atom. The instrumental developments in high resolution resonant inelastic soft x-ray scattering are currently accelerating and will enable broad application of the presented approach. With this multidimensional potential energy surfaces that characterize collective phenomena such as (bio)molecular function or high-temperature superconductivity will become accessible in near future.

  13. Development Of Position-sensitive Cadmium Zinc Telluride Detectors For High-energy X-ray Astrophysics

    CERN Document Server

    Slavis, K R

    2001-01-01

    This dissertation reports on the studies of an orthogonal cross-strip CdZnTe detector for high-energy X-ray (20–250 keV) astrophysics applications. The intrinsic three-dimensional detector response and the effectiveness of using various shielding techniques at balloon altitudes are investigated. This detector has great promise for use as the imaging detector of a large- area, coded-mask instrument in an all-sky high-energy X- ray survey or as the focal-plane detector for an X-ray focusing telescope (Constellation-X) for high throughput, high resolution X-ray spectroscopy (6–40 keV). The most recent hard X-ray all-sky survey was conducted by HEAO-1/A4 in 1978, and one has not been conducted since then due to performance limitations of available X-ray detector technology. The next generation instruments need to have sub-degree angular resolution, good sensitivity in the hard X-ray band (3σ sensitivity to sub- mCrab), and few keV energy resolution. This performance is demonstrated u...

  14. Feasibility of kilovoltage x-ray energy modulation by gaseous media and its application in contrast-enhanced radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Facundo-Flores, E. L.; Garnica-Garza, H. M. [Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional, Unidad Monterrey, Vía del Conocimiento 201 Parque PIIT, Apodaca, Nuevo León 66600 (Mexico)

    2013-09-15

    Purpose: To present a method to modulate the energy contents of a kilovoltage x-ray beam that makes use of a gas as the modulating medium. The method is capable of producing arbitrary x-ray spectra by varying the pressure of the modulating gas and the peak kilovoltage (kVp) of the x-ray beams whose energy is being modulated.Methods: An aluminum chamber was machined with a 0.5 cm wall thickness, designed to withstand pressures of more than 80 atm. A pressure sensor and electrovalves were used to monitor and regulate the gas pressure. Argon was used as the modulating gas. A CdTe spectrometer was used to measure x-ray spectra for different combinations of kVp and gas pressure, thus obtaining a set of basis x-ray functions. An arbitrary x-ray spectrum can then be formed by the linear combination of such basis functions. In order to show one possible application of the modulation method, a contrast-enhanced radiotherapy prostate treatment was optimized with respect to the x-ray beam energy, without restrictions on the possible shape of the resultant x-ray spectra.Results: The x-ray spectra basis functions obtained display a smooth and gradual variation of their average energy as a function of the gas pressure for a given kVp, sometimes in the order of 1 or 2 keV. This gradual variation would be difficult to obtain with a conventional aluminum or copper filters, as the change in thickness necessary to reproduce the data presented would be in the order of micrometers, making necessary the use of a large number of such filters. Using the modulation method presented here, the authors were able to reconstruct the optimized x-ray spectra from the measured basis functions, for different optimization objectives.Conclusions: A method has been developed that allows for the controlled modulation of the energy contents of kilovoltage x-ray spectra. The method has been shown to be able to reproduce spectra of arbitrary shape, such as those obtained from the optimization of contrast

  15. Zernike phase contrast in high-energy x-ray transmission microscopy based on refractive optics.

    Science.gov (United States)

    Falch, Ken Vidar; Lyubomirsky, Mikhail; Casari, Daniele; Snigirev, Anatoly; Snigireva, Irina; Detlefs, Carsten; Michiel, Marco Di; Lyatun, Ivan; Mathiesen, Ragnvald H

    2018-01-01

    The current work represents the first implementation of Zernike phase contrast for compound refractive lens based x-ray microscopy, and also the first successful Zernike phase contrast experiment at photon energies above 12 keV. Phase contrast was achieved by fitting a compound refractive lens with a circular phase plate. The resolution is demonstrated to be sub-micron, and can be improved using already existing technology. The possibility of combining the technique with polychromatic radiation is considered, and a preliminary test experiment was performed with positive results. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. A fast energy-dispersive multi-element detector for X-ray absorption spectroscopy.

    Science.gov (United States)

    Welter, Edmund; Hansen, Karsten; Reckleben, Christian; Diehl, Inge

    2009-03-01

    In this paper results are presented from fluorescence-yield X-ray absorption fine-structure spectroscopy measurements with a new seven-cell silicon drift detector (SDD) module. The complete module, including an integrated circuit for the detector readout, was developed and realised at DESY utilizing a monolithic seven-cell SDD. The new detector module is optimized for applications like XAFS which require an energy resolution of approximately 250-300 eV (FWHM Mn Kalpha) at high count rates. Measurements during the commissioning phase proved the excellent performance for this type of application.

  17. Development of apparatus for multiple energy X-ray holography at SPring-8

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Kouichi E-mail: khayashi@imr.tohoku.ac.jphayashi@karma.mtl.kyoto-u.ac.jp; Miyake, Masao; Tobioka, Tomoaki; Awakura, Yasuhiro; Suzuki, Motohiro; Hayakawa, Shinjiro

    2001-07-21

    We developed an apparatus for multiple energy X-ray holography (MEXH) at third generation synchrotron facility, SPring-8. The combination system of a cylindrical lithium fluoride crystal and an avalanche photo diode in our apparatus enabled high countrate detection of the fluorescence from samples. From the measurements repeated 10 times, reproducible holographic undulations were obtained from the strontium titanate single crystal, although 10% intensity change of the incident beam occurred. This result revealed that the holographic data provided by our MEXH apparatus was highly stable to the variation of the incident beam intensity.

  18. Application of energy dispersive X-ray fluorescence spectrometry (EDX) in a case of methomyl ingestion.

    Science.gov (United States)

    Kinoshita, Hiroshi; Tanaka, Naoko; Jamal, Mostofa; Kumihashi, Mitsuru; Okuzono, Ryota; Tsutsui, Kunihiko; Ameno, Kiyoshi

    2013-04-10

    We applied energy dispersive X-ray fluorescence spectrometry (EDX) in a case of poisoning by methomyl, a carbamate pesticide. Quantitative GC/MS analysis showed that the concentration of methomyl-oxime in the femoral blood was 4.0 μg/ml. The elemental analysis by EDX identified the high peak of silicon and sulfur in the stomach contents. We concluded that the cause of his death was methomyl poisoning. This indicates that screening of stomach contents by EDX provides useful information for the forensic diagnosis. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Scanning three-dimensional x-ray diffraction microscopy using a high-energy microbeam

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Y., E-mail: y-hayashi@mosk.tytlabs.co.jp; Hirose, Y.; Seno, Y. [Toyota Central R& D Toyota Central R& D Labs., Inc., 41-1 Nagakute Aichi 480-1192 Japan (Japan)

    2016-07-27

    A scanning three-dimensional X-ray diffraction (3DXRD) microscope apparatus with a high-energy microbeam was installed at the BL33XU Toyota beamline at SPring-8. The size of the 50 keV beam focused using Kirkpatrick-Baez mirrors was 1.3 μm wide and 1.6 μm high in full width at half maximum. The scanning 3DXRD method was tested for a cold-rolled carbon steel sheet sample. A three-dimensional orientation map with 37 {sup 3} voxels was obtained.

  20. A method for high-energy, low-dose mammography using edge illumination x-ray phase-contrast imaging

    Science.gov (United States)

    Diemoz, Paul C.; Bravin, Alberto; Sztrókay-Gaul, Anikó; Ruat, Marie; Grandl, Susanne; Mayr, Doris; Auweter, Sigrid; Mittone, Alberto; Brun, Emmanuel; Ponchut, Cyril; Reiser, Maximilian F.; Coan, Paola; Olivo, Alessandro

    2016-12-01

    Since the breast is one of the most radiosensitive organs, mammography is arguably the area where lowering radiation dose is of the uttermost importance. Phase-based x-ray imaging methods can provide opportunities in this sense, since they do not require x-rays to be stopped in tissue for image contrast to be generated. Therefore, x-ray energy can be considerably increased compared to those usually exploited by conventional mammography. In this article we show how a novel, optimized approach can lead to considerable dose reductions. This was achieved by matching the edge-illumination phase method, which reaches very high angular sensitivity also at high x-ray energies, to an appropriate image processing algorithm and to a virtually noise-free detection technology capable of reaching almost 100% efficiency at the same energies. Importantly, while proof-of-concept was obtained at a synchrotron, the method has potential for a translation to conventional sources.

  1. Segmentation-free x-ray energy spectrum estimation for computed tomography

    CERN Document Server

    Zhao, Wei; Niu, Tianye

    2016-01-01

    X-ray energy spectrum plays an essential role in imaging and related tasks. Due to the high photon flux of clinical CT scanners, most of the spectrum estimation methods are indirect and are usually suffered from various limitations. The recently proposed indirect transmission measurement-based method requires at least the segmentation of one material, which is insufficient for CT images of highly noisy and with artifacts. To combat for the bottleneck of spectrum estimation using segmented CT images, in this study, we develop a segmentation-free indirect transmission measurement based energy spectrum estimation method using dual-energy material decomposition. The general principle of the method is to compare polychromatic forward projection with raw projection to calibrate a set of unknown weights which are used to express the unknown spectrum together with a set of model spectra. After applying dual-energy material decomposition using high- and low-energy raw projection data, polychromatic forward projection ...

  2. Anisotropic Thermal Expansion of Zirconium Diboride: An Energy-Dispersive X-Ray Diffraction Study

    Directory of Open Access Journals (Sweden)

    William A. Paxton

    2016-01-01

    Full Text Available Zirconium diboride (ZrB2 is an attractive material due to its thermal and electrical properties. In recent years, ZrB2 has been investigated as a superior replacement for sapphire when used as a substrate for gallium nitride devices. Like sapphire, ZrB2 has an anisotropic hexagonal structure which defines its directionally dependent properties. However, the anisotropic behavior of ZrB2 is not well understood. In this paper, we use energy-dispersive synchrotron X-ray diffraction to measure the thermal expansion of polycrystalline ZrB2 powder from 300 to 1150 K. Nine Bragg reflections are fit using Pseudo-Voigt peak profiles and used to compute the a and c lattice parameters using a nonlinear least-squares approximation. The temperature-dependent instantaneous thermal expansion coefficients are determined for each a-axis and c-axis direction and are described by the following equations: αa = (4.1507×10-6 + 5.1086 × 10-9(T-293.15/(1+4.1507 × 10-6(T-293.15 + 2.5543×10-9(T-293.152 and αc = (4.5374×10-6 + 4.3004×10-9(T-293.15/(1+4.5374×10-6(T-293.15 + 2.1502×10-9(T-293.152. Our results are within range of previously reported values but describe the temperature anisotropy in more detail. We show that anisotropic expansion coefficients converge to the same value at about 780 K and diverge at higher temperatures. Results are compared with other reported values.

  3. X-ray Absorption Spectroscopy Characterization of Electrochemical Processes in Renewable Energy Storage and Conversion Devices

    Energy Technology Data Exchange (ETDEWEB)

    Farmand, Maryam [George Washington Univ., Washington, DC (United States)

    2013-05-19

    The development of better energy conversion and storage devices, such as fuel cells and batteries, is crucial for reduction of our global carbon footprint and improving the quality of the air we breathe. However, both of these technologies face important challenges. The development of lower cost and better electrode materials, which are more durable and allow more control over the electrochemical reactions occurring at the electrode/electrolyte interface, is perhaps most important for meeting these challenges. Hence, full characterization of the electrochemical processes that occur at the electrodes is vital for intelligent design of more energy efficient electrodes. X-ray absorption spectroscopy (XAS) is a short-range order, element specific technique that can be utilized to probe the processes occurring at operating electrode surfaces, as well for studying the amorphous materials and nano-particles making up the electrodes. It has been increasingly used in recent years to study fuel cell catalysts through application of the and #916; and mgr; XANES technique, in combination with the more traditional X-ray Absorption Near Edge Structure (XANES) and Extended X-ray Absorption Fine Structure (EXAFS) techniques. The and #916; and mgr; XANES data analysis technique, previously developed and applied to heterogeneous catalysts and fuel cell electrocatalysts by the GWU group, was extended in this work to provide for the first time space resolved adsorbate coverages on both electrodes of a direct methanol fuel cell. Even more importantly, the and #916; and mgr; technique was applied for the first time to battery relevant materials, where bulk properties such as the oxidation state and local geometry of a cathode are followed.

  4. Investigation of multilayered nanocomposites as low energy X-Rays attenuators

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Liliane; Batista, Adriana S.M.; Nascimento, Jefferson P.; Furtado, Clascídia A.; Faria, Luiz O., E-mail: asfisica@gmail.com, E-mail: adriananuclear@yahoo.com.br, E-mail: farialo@cdtn.br, E-mail: nascimentopatricio@yahoo.com.br, E-mail: clas@cdtn.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-11-01

    The development of radiation attenuating materials has application in radioprotection and conditioning of short-lived waste. Polymeric materials can serve as a matrix for the dispersion of nanomaterials with good attenuation features, resulting in lightweight, conformable, flexible and easy-to-process materials. Thus, some well-known shielding materials could be used in low proportion for the formation of new materials. On the other hand, nanostructured carbon materials, such as graphene oxide (GO) and carbon nanotubes (NTCs), have been reported recently to show enhanced attenuation properties. In this sense, polymeric matrixes provide the necessary flexibility for use in various applications that require molding. For the present work, poly(vinylidene fluoride) [PVDF] homopolymers and its fluorinated copolymers were filled with nanosized metallic and graphene oxides in order to produce nanocomposites with increased low energy X-ray attenuation efficiency. Film samples of PVDF/reduced Graphene Oxide [PVDF/rGO] and Poly(vinylidene fluoride – tryfluorethylene)/Barium Oxide [P(VDF-TrFE)/BaO] were synthesized. In a second step, the samples were then sandwiched between Kapton® layers and exposed to X-rays source (8.5 keV). The samples were characterized with Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy (EDS). The attenuation coefficient was evaluated and compared with the attenuation of the individual constituents. It was observed an increase in the linear attenuation coefficient of the layered materials, justifying further investigation of these nanostructured composites as X-ray or gamma radiation attenuators. (author)

  5. Interplay between relativistic energy corrections and resonant excitations in x-ray multiphoton ionization dynamics of Xe atoms

    Science.gov (United States)

    Toyota, Koudai; Son, Sang-Kil; Santra, Robin

    2017-04-01

    In this paper, we theoretically study x-ray multiphoton ionization dynamics of heavy atoms taking into account relativistic and resonance effects. When an atom is exposed to an intense x-ray pulse generated by an x-ray free-electron laser (XFEL), it is ionized to a highly charged ion via a sequence of single-photon ionization and accompanying relaxation processes, and its final charge state is limited by the last ionic state that can be ionized by a single-photon ionization. If x-ray multiphoton ionization involves deep inner-shell electrons in heavy atoms, energy shifts by relativistic effects play an important role in ionization dynamics, as pointed out in Phys. Rev. Lett. 110, 173005 (2013), 10.1103/PhysRevLett.110.173005. On the other hand, if the x-ray beam has a broad energy bandwidth, the high-intensity x-ray pulse can drive resonant photoexcitations for a broad range of ionic states and ionize even beyond the direct one-photon ionization limit, as first proposed in Nat. Photon. 6, 858 (2012), 10.1038/nphoton.2012.261. To investigate both relativistic and resonance effects, we extend the xatom toolkit to incorporate relativistic energy corrections and resonant excitations in x-ray multiphoton ionization dynamics calculations. Charge-state distributions are calculated for Xe atoms interacting with intense XFEL pulses at a photon energy of 1.5 keV and 5.5 keV, respectively. For both photon energies, we demonstrate that the role of resonant excitations in ionization dynamics is altered due to significant shifts of orbital energy levels by relativistic effects. Therefore, it is necessary to take into account both effects to accurately simulate multiphoton multiple ionization dynamics at high x-ray intensity.

  6. Time-resolved soft-x-ray studies of energy transport in layered and planar laser-driven targets

    Energy Technology Data Exchange (ETDEWEB)

    Stradling, G.L.

    1982-04-19

    New low-energy x-ray diagnostic techniques are used to explore energy-transport processes in laser heated plasmas. Streak cameras are used to provide 15-psec time-resolution measurements of subkeV x-ray emission. A very thin (50 ..mu..g/cm/sup 2/) carbon substrate provides a low-energy x-ray transparent window to the transmission photocathode of this soft x-ray streak camera. Active differential vacuum pumping of the instrument is required. The use of high-sensitivity, low secondary-electron energy-spread CsI photocathodes in x-ray streak cameras is also described. Significant increases in sensitivity with only a small and intermittant decrease in dynamic range were observed. These coherent, complementary advances in subkeV, time-resolved x-ray diagnostic capability are applied to energy-transport investigations of 1.06-..mu..m laser plasmas. Both solid disk targets of a variety of Z's as well as Be-on-Al layered-disk targets were irradiated with 700-psec laser pulses of selected intensity between 3 x 10/sup 14/ W/cm/sup 2/ and 1 x 10/sup 15/ W/cm/sup 2/.

  7. Characterizing the behavior of scattered radiation in multi-energy x-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sossin, Artur, E-mail: artur.sossin@gmail.com [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France); Rebuffel, V.; Tabary, J. [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France); Létang, J.M.; Freud, N. [Univ Lyon, INSA-Lyon, Université Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Centre Léon Bérard, CREATIS UMR 5220 U1206, F-69373 Lyon (France); Verger, L. [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France)

    2017-04-01

    Scattered radiation results in various undesirable effects in medical diagnostics, non-destructive testing (NDT) and security x-ray imaging. Despite numerous studies characterizing this phenomenon and its effects, the knowledge of its behavior in the energy domain remains limited. The present study aims at summarizing some key insights on scattered radiation originating from the inspected object. In addition, various simulations and experiments with limited collimation on both simplified and realistic phantoms were conducted in order to study scatter behavior in multi-energy x-ray imaging. Results showed that the spectrum shape of the scatter component can be considered preserved in the first approximation across the image plane for various acquisition geometries and phantoms. The variations exhibited by the scatter spectrum were below 10% for most examined cases. Furthermore, the corresponding spectrum shape proved to be also relatively invariant for different experimental angular projections of one of the examined phantoms. The observed property of scattered radiation can potentially lead to the decoupling of spatial and energy scatter components, which can in turn enable speed ups in scatter simulations and reduce the complexity of scatter correction.

  8. Exploring coherent phenomena and energy discrimination in X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Thomas

    2011-05-04

    Conventional X-ray imaging is based on the generation of photons in materials that are selected for different applications according to their densities, dimensions, and atomic numbers. The photons produced in these targets are commonly detected by measuring the integrated amount of energy released in films or digital imaging systems. This thesis aims at extending these two paradigms. First, it is shown that the use of single-crystalline, i.e. well-ordered targets, can significantly soften photon spectra created by megavoltage electrons when compared to usual targets. The reason for this is an effect called ''coherent bremsstrahlung''. It is shown that this type of radiation bears the potential of increasing the quality of megavoltage images and reducing radiation dose for image guided radiotherapy. Second, new spectroscopic pixel detectors of the Medipix2 family operated with cadmium telluride sensors are characterised and thus potential benefits and difficulties for X-ray imaging are investigated. Besides describing in detail how to calibrate these detectors, emphasis is placed on determining their energy responses, modulation transfer functions, and detective quantum efficiencies. Requirements for photon counting megavoltage imaging are discussed. The detector systems studied are finally used to perform spectral computed tomography and to illustrate the benefits of energy discrimination for coherent scatter imaging. (orig.)

  9. Experimental results on hard x-ray energy emitted by a low-energy plasma focus device: a radiographic image analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zambra, Marcelo; Pavez, Cristian; Pasten, Denisse; Moreno, Jose; Soto, Leopoldo [Comision Chilena de EnergIa Nuclear, Amunategui 95, PO Box 188-D, Santiago (Chile); Silva, Patricio, E-mail: mzambra@cchen.c

    2009-12-15

    The PF-400J plasma focus device (400 J of energy) was studied in a similar way to a pulsed source of high-energy x-ray radiation. High-sensitivity fast-response commercial radiographic film and different metal filter array combinations were used to study the energy of the proper emitted x-ray. The effective energy of the hard x-ray radiation is studied and discussed in terms of its effective mean attenuation with the penetration distance on different metallic samples when the x-ray pulsed beam is supposed monoenergetic. These results were then used to assess the energetic properties of the pulsed radiation when different x-ray film-filter array combinations were irradiated between tens to almost 160 effective pulses of x-ray coming from the PF-400J device.

  10. Experimental results on hard x-ray energy emitted by a low-energy plasma focus device: a radiographic image analysis

    Science.gov (United States)

    Zambra, Marcelo; Silva, Patricio; Pavez, Cristian; Pasten, Denisse; Moreno, José; Soto, Leopoldo

    2009-12-01

    The PF-400J plasma focus device (400 J of energy) was studied in a similar way to a pulsed source of high-energy x-ray radiation. High-sensitivity fast-response commercial radiographic film and different metal filter array combinations were used to study the energy of the proper emitted x-ray. The effective energy of the hard x-ray radiation is studied and discussed in terms of its effective mean attenuation with the penetration distance on different metallic samples when the x-ray pulsed beam is supposed monoenergetic. These results were then used to assess the energetic properties of the pulsed radiation when different x-ray film-filter array combinations were irradiated between tens to almost 160 effective pulses of x-ray coming from the PF-400J device.

  11. Determination of the weld thickness of turbine for aircraft engine by high-energy X-ray tomography

    Directory of Open Access Journals (Sweden)

    Zhong Yang

    2017-01-01

    Full Text Available It is necessary to test the weld thickness of turbine, as it is one of the most important parts for aircraft engine. The weld thickness of turbine for aircraft engine by high-energy X-ray tomography was determined. We used an X-ray tube and a betatron as X-ray sources. The wall thickness of two tubes and weld thickness of turbine were measured. It is shown that the high-energy X-ray tomography system is determined the wall thickness of the tube and the weld thickness of turbine with high accuracy. We also studied the method to reduce scattered radiation. All experiments were carried out in the non-destructive testing (NDT Institute of Tomsk Polytechnic University (TPU.

  12. Direct X-ray radiogrammetry versus dual-energy X-ray absorptiometry: assessment of bone density in children treated for acute lymphoblastic leukaemia and growth hormone deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Rijn, Rick R. van; Wittenberg, Rianne [Academic Medical Centre Amsterdam, Department of Radiology, Amsterdam Zuid-Oost (Netherlands); Boot, Annemieke; Sluis, Inge M. van der; MuinckKeizer-Schrama, Sabine M.P.F. de [Erasmus MC-Sophia Children' s Hospital, Department of Paediatric Endocrinology, Rotterdam (Netherlands); Heuvel-Eibrink, Marry M. van den [Erasmus MC-Sophia Children' s Hospital, Department of Paediatric Haematology/Oncology, Rotterdam (Netherlands); Lequin, Maarten H. [Erasmus MC-Sophia Children' s Hospital, Department of Paediatric Radiology, Rotterdam (Netherlands); Kuijk, Cornelis Van [University Medical Centre ' Radboud' , Department of Radiology, Nijmegen (Netherlands)

    2006-03-15

    In recent years interest in bone densitometry in children has increased. To evaluate the clinical application of digital X-ray radiogrammetry (DXR) and compare the results with those of dual-energy X-ray absorptiometry (DXA). A total of 41 children with acute lymphoblastic leukaemia (ALL) and 26 children with growth hormone deficiency (GHD) were included in this longitudinal study. Radiographs of the left hand were obtained and used for DXR. DXA of the total body and of the lumbar spine was performed. In both study populations significant correlations between DXR and DXA were found, and, with the exception of the correlation between DXR bone mineral density (DXR-BMD) and bone mineral apparent density in the GHD population, all correlations had a P-value of <0.001. During treatment a change in DXR-BMD was found in children with GHD. Our study showed that DXR in a paediatric population shows a strong correlation with DXA of the lumbar spine and total body and that it is able to detect a change in BMD during treatment. (orig.)

  13. Structural studies coupling X-ray diffraction and high-energy X-ray scattering in the UO2(2+)-HBr(aq) system.

    Science.gov (United States)

    Wilson, Richard E; Skanthakumar, S; Cahill, C L; Soderholm, L

    2011-11-07

    The structural chemistry of uranium(VI) in concentrated aqueous hydrobromic acid solutions was investigated using both single crystal X-ray diffraction and synchrotron-based high-energy X-ray scattering (HEXS) to reveal the structure of the uranium(VI) complexes in solution prior to crystallization. The crystal structures of a series of uranyl tetrabromide salts are reported, including Cs(2)UO(2)Br(4), Rb(2)UO(2)Br(4)·2H(2)O, K(2)UO(2)Br(4)·2H(2)O, and (NH(4))(2)UO(2)Br(4)·2H(2)O, as well as a molecular dimer of uranium(VI), (UO(2))(2)(OH)(2)Br(2)(H(2)O)(4). Limited correspondence exists between the structures observed in the solid state and those in solution. Quantitative analysis of the HEXS data show an average U-Br coordination number of 1.9(2) in solution, in contrast to the U-Br coordination number of 4 in the solid salts. © 2011 American Chemical Society

  14. Quantification of metals in lipstick by energy dispersive X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Wouk, Luana Cristina; Melquiades, Fabio Luiz [Universidade Estadual do Centro Oeste (UNICENTRO), PR (Brazil). Dept. de Fisica

    2011-07-01

    Full text: The objective of this work is to analyze lipstick and lip balm by Energy Dispersive X-Ray Fluorescence and verify if the concentration of the found elements are in accordance with federal rules. Two lip balm and 30 lipstick commercially available were analyzed without preparation. The samples were rubbed on a mylar film until they form a relatively homogeneous layer over entire surface of the film. The superficial density of the samples ranged from 0,0004 to 0,015 g cm{sup -2} , which characterize thin film geometry. Sensitivity values were determined using MicroMatter standards. The measurement system, from Applied Nuclear Physics Laboratory of UEL, consists in a Si-PIN X-ray detector (221 eV resolution for 5,9 keV line, 25 {mu}m Be window) and a mini X-ray tube (4W, Ag target, 50 {mu}m Ag filter). One of the lip balm presented 2620 {+-} 477 {mu}g g{sup -1} of Ti and in the other sample none inorganic elements, which characterize a formulation based on organic compounds. In the lipstick were found the following elements and the number of samples in which it appears, with its respective range of concentration in {mu}g g{sup -1}: Ti (17) 691 to 12721, Fe (22) 237 to 16377, Zn (3) 105 to 2850, Br (2) 510 to 3097, Sr(4) 254 to 1170, Ba (2) 58170 to 90506 and Bi (1) 16275 {+-} 798. According to Brazilian federal rules (ANVISA 79.094) it is not permitted the presence of As and Pb in the formulations. The methodology demonstrated to be suitable for quantification of metals at in natura samples of lipsticks, discarding sample preparation. In sequence a detailed study of the influence of these elements on human health will be performed. (author)

  15. Multi-energy x-ray detectors to improve air-cargo security

    Science.gov (United States)

    Paulus, Caroline; Moulin, Vincent; Perion, Didier; Radisson, Patrick; Verger, Loïck

    2017-05-01

    X-ray based systems have been used for decades to screen luggage or cargo to detect illicit material. The advent of energy-sensitive photon-counting x-ray detectors mainly based on Cd(Zn)Te semi-conductor technology enables to improve discrimination between materials compared to single or dual energy technology. The presented work is part of the EUROSKY European project to develop a Single European Secure Air-Cargo Space. "Cargo" context implies the presence of relatively heavy objects and with potentially high atomic number. All the study is conducted on simulations with three different detectors: a typical dual energy sandwich detector, a realistic model of the commercial ME100 multi-energy detector marketed by MULTIX, and a ME100 "Cargo": a not yet existing modified multi-energy version of the ME100 more suited to air freight cargo inspection. Firstly, a comparison on simulated measurements shows the performances improvement of the new multi-energy detectors compared to the current dual-energy one. The relative performances are evaluated according to different criteria of separability or contrast-to-noise ratio and the impact of different parameters is studied (influence of channel number, type of materials and tube voltage). Secondly, performances of multi-energy detectors for overlaps processing in a dual-view system is accessed: the case of orthogonal projections has been studied, one giving dimensional values, the other one providing spectral data to assess effective atomic number. A method of overlap correction has been proposed and extended to multi-layer objects case. Therefore, Calibration and processing based on bi-material decomposition have been adapted for this purpose.

  16. High energy white beam x-ray diffraction studies of residual strains in engineering components

    Science.gov (United States)

    Zhang, S. Y.; Vorster, W.; Jun, T. S.; Song, X.; Golshan, M.; Laundy, D.; Walsh, M. J.; Korsunsky, A. M.

    2008-09-01

    In order to predict the durability of engineering components and improve performance, it is mandatory to understand residual stresses. The last decade has witnessed a significant increase of residual stress evaluation using diffraction of penetrating radiation, such as neutrons or high energy X-rays. They provide a powerful non-destructive method for determining the level of residual stresses in engineering components through precise characterisation of interplanar crystal lattice spacing. The unique non-destructive nature of these measurement techniques is particularly beneficial in the context of engineering design, since it allows the evaluation of a variety of structural and deformational parameters inside real components without material removal, or at worst with minimal interference. However, while most real engineering components have complex shape and are often large in size, leading to measurement and interpretation difficulties, since experimental facilities usually have limited space for mounting the sample, limited sample travel range, limited loading capacity of the sample positioning system, etc. Consequently, samples often have to be sectioned, requiring appropriate corrections on measured data; or facilities must be improved. Our research group has contributed to the development of engineering applications of high-energy X-ray diffraction methods for residual stress evaluation, both at synchrotron sources and in the lab setting, including multiple detector setup, large engineering component manipulation and measurement at the UK Synchrotron Radiation Source (SRS Daresbury), and in our lab at Oxford. A nickel base superalloy combustion casing and a large MIG welded Al alloy plate were successfully studied.

  17. Energy-sensitive photon counting detector-based X-ray computed tomography.

    Science.gov (United States)

    Taguchi, Katsuyuki

    2017-03-01

    Energy-sensitive photon counting detectors (PCDs) have recently been developed for medical X-ray computed tomography (CT) imaging and a handful of prototype PCD-CT systems have been built and evaluated. PCDs detect X-rays by using mechanisms that are completely different from the current CT detectors (i.e., energy integrating detectors or EIDs); PCDs count photons and obtain the information of the object tissues (i.e., the effective atomic numbers and mass densities) to be imaged. Therefore, these PCDs have the potential not only for evolution-to improve the current CT images such as providing dose reduction-but also for a revolution-to enable novel applications with a new concept such as molecular CT imaging. The performance of PCDs, however, is not flawless, and thus, it requires integrated efforts to develop PCD-CT for clinical use. In this article, we review the current status and the prediction for the future of PCDs, PCD-CT systems, and potential clinical applications.

  18. High-energy x-ray Talbot-Lau radiography of a human knee

    Science.gov (United States)

    Horn, F.; Gelse, K.; Jabari, S.; Hauke, C.; Kaeppler, S.; Ludwig, V.; Meyer, P.; Michel, T.; Mohr, J.; Pelzer, G.; Rieger, J.; Riess, C.; Seifert, M.; Anton, G.

    2017-08-01

    We report on a radiographic measurement of an ex vivo human knee using a grating-based phase-contrast imaging setup and a medical x-ray tube at a tube voltage of 70 kV. The measurement has been carried out using a Talbot-Lau setup that is suitable to achieve a high visibility in the energy regime of medical imaging. In a medical reading by an experienced trauma surgeon signatures of chondrocalcinosis in the medial meniscus have been identified more evidently using the dark-field image in comparison to the conventional attenuation image. The analysis has been carried out at various dose levels down to 0.14 mGy measured as air kerma, which is a dose comparable to clinically used radiographic devices. The diagnosis has been confirmed by a histological analysis of the meniscus tissue. In the introduced high-frequency filtered phase-contrast image the anterior and posterior horn of the medial meniscus and the posterior cruciate ligament have also been visible. Furthermore, atherosclerotic plaque is visible in both imaging modalities, attenuation and dark-field, despite the presence of overlaying bone. This measurement, for the first time, proves the feasibility of Talbot-Lau x-ray imaging at high-energy spectra above 40 kVp and reasonable dose levels with regard to spacious and dense objects.

  19. A High-Energy, Ultrashort-Pulse X-Ray System for the Dynamic Study of Heavy, Dense Materials

    Energy Technology Data Exchange (ETDEWEB)

    Gibson, David Jeremy [Univ. of California, Davis, CA (United States)

    2004-01-01

    Thomson-scattering based x-ray radiation sources, in which a laser beam is scattered off a relativistic electron beam resulting in a high-energy x-ray beam, are currently being developed by several groups around the world to enable studies of dynamic material properties which require temporal resolution on the order of tens of femtoseconds to tens of picoseconds. These sources offer pulses that are shorter than available from synchrotrons, more tunable than available from so-called Ka sources, and more penetrating and more directly probing than ultrafast lasers. Furthermore, Thomson-scattering sources can scale directly up to x-ray energies in the few MeV range, providing peak brightnesses far exceeding any other sources in this regime. This dissertation presents the development effort of one such source at Lawrence Livermore National Laboratory, the Picosecond Laser-Electron InterAction for the Dynamic Evaluation of Structures (PLEIADES) project, designed to target energies from 30 keV to 200 keV, with a peak brightness on the order of 1018 photons • s-1 • mm-2 • mrad-2 • 0.01% bandwidth-1. A 10 TW Ti:Sapphire based laser system provides the photons for the interaction, and a 100 MeV accelerator with a 1.6 cell S-Band photoinjector at the front end provides the electron beam. The details of both these systems are presented, as is the initial x-ray production and characterization, validating the theory of Thomson scattering. In addition to the systems used to enable PLEIADES, two alternative systems are discussed. An 8.5 GHz X-Band photoinjector, capable of sustaining higher accelerating gradients and producing lower emittance electron beams in a smaller space than the S-Band gun, is presented, and the initial operation and commissioning of this gun is presented. Also, a hybrid chirped-pulse amplification system is presented as an alternative to the standard regenerative amplifier technology in high

  20. Low-energy d-d excitations in MnO studied by resonant x-ray fluorescence spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Butorin, S.M.; Guo, J.; Magnuson, M. [Uppsala Univ. (Sweden)] [and others

    1997-04-01

    Resonant soft X-ray emission spectroscopy has been demonstrated to possess interesting abilities for studies of electronic structure in various systems, such as symmetry probing, alignment and polarization dependence, sensitivity to channel interference, etc. In the present abstract the authors focus on the feasibility of resonant soft X-ray emission to probe low energy excitations by means of resonant electronic X-ray Raman scattering. Resonant X-ray emission can be regarded as an inelastic scattering process where a system in the ground state is transferred to a low excited state via a virtual core excitation. The energy closeness to a core excitation of the exciting radiation enhances the (generally) low probability for inelastic scattering at these wavelengths. Therefore soft X-ray emission spectroscopy (in resonant electronic Raman mode) can be used to study low energy d-d excitations in transition metal systems. The involvement of the intermediate core state allows one to use the selection rules of X-ray emission, and the appearance of the elastically scattered line in the spectra provides the reference to the ground state.

  1. An inelastic X-ray spectrometer with 2.2 meV energy resolution

    CERN Document Server

    Sinn, H; Alatas, A; Barraza, J; Bortel, G; Burkel, E; Shu, D; Sturhahn, W; Sutter, J P; Toellner, T S; Zhao, J

    2001-01-01

    We present a new spectrometer at the Advanced Photon Source for inelastic X-ray scattering with an energy resolution of 2.2 meV at an incident energy of 21.6 keV. For monochromatization, a nested structure of one silicon channel cut and one 'artificial' channel cut is used in forward-scattering geometry. The energy analysis is achieved by a two-dimensional focusing silicon analyzer in backscattering geometry. In the first demonstration experiments, elastic scattering from a Plexiglas sup T sup M sample and two dispersion curves in a beryllium single crystal were measured. Based on these data sets, the performance of the new spectrometer is discussed.

  2. X-ray beam design for multi-energy imaging with charge-integrating detector: A simulation study

    Science.gov (United States)

    Baek, Cheol-Ha; Kim, Daehong

    2015-11-01

    Multi-energy X-ray imaging systems have been widely used for clinical examinations. In order to enhance the imaging quality of these X-ray systems, a dual-energy system that can obtain specific information has been developed in order to discriminate different materials. Although the dual-energy system shows reliable performance for clinical applications, it is necessary to improve the method in order to minimize radiation dose, reduce projection error, and increase image contrast. The purpose of this study is to develop a triple energy technique that can discriminate three materials for the purpose of enhancing imaging quality and patient safety. The X-ray system tube voltage was varied from 40 to 90 kV, and filters (that can generate three X-ray energies) were installed, consisting of pure elemental materials in foil form (including Al, Cu, I, Ba, Ce, Gd, Er, and W). The X-ray beam was evaluated with respect to mean energy ratio, contrast variation ratio, and exposure efficiency. In order to estimate the performance of the suggested technique, Monte Carlo was conducted, and the results were compared to the photon-counting method. As a result, the density maps of iodine, aluminum, and polymethyl methacrylate (PMMA) using the X-ray beam were more accurate in comparison to that obtained with the photon-counting method. According to the results, the suggested triple energy technique can improve the accuracy of the determination of thickness of density. Moreover, the X-ray beam could reduce unnecessary patient dose.

  3. CALIBRATION OF THE NuSTAR HIGH-ENERGY FOCUSING X-RAY TELESCOPE

    Energy Technology Data Exchange (ETDEWEB)

    Madsen, Kristin K.; Harrison, Fiona A.; Grefenstette, Brian W.; Miyasaka, Hiromasa; Forster, Karl; Fuerst, Felix; Rana, Vikram; Walton, Dominic J. [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Markwardt, Craig B. [Goddard Space Flight Center, Greenbelt, MD 20771 (United States); An, Hongjun [Department of Physics, McGill University, Montreal, Quebec, H3A 2T8 (Canada); Bachetti, Matteo [Université de Toulouse, UPS-OMP, IRAP, Toulouse (France); Kitaguchi, Takao [RIKEN, 2-1 Hirosawa, Wako, Saitama, 351-0198 (Japan); Bhalerao, Varun [Inter-University Center for Astronomy and Astrophysics, Post Bag 4, Ganeshkhind, Pune 411007 (India); Boggs, Steve; Craig, William W. [Space Sciences Laboratory, University of California, Berkeley, CA 94720 (United States); Christensen, Finn E. [DTU Space, National Space Institute, Technical University of Denmark, Elektronvej 327, DK-2800 Lyngby (Denmark); Hailey, Charles J. [Columbia Astrophysics Laboratory, Columbia University, NY 10027 (United States); Perri, Matteo; Puccetti, Simonetta [ASI Science Data Center, via Galileo Galilei, I-00044, Frascati (Italy); Stern, Daniel [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); and others

    2015-09-15

    We present the calibration of the Nuclear Spectroscopic Telescope Array (NuSTAR) X-ray satellite. We used the Crab as the primary effective area calibrator and constructed a piece-wise linear spline function to modify the vignetting response. The achieved residuals for all off-axis angles and energies, compared to the assumed spectrum, are typically better than ±2% up to 40 keV and 5%–10% above due to limited counting statistics. An empirical adjustment to the theoretical two-dimensional point-spread function (PSF) was found using several strong point sources, and no increase of the PSF half-power diameter has been observed since the beginning of the mission. We report on the detector gain calibration, good to 60 eV for all grades, and discuss the timing capabilities of the observatory, which has an absolute timing of ±3 ms. Finally, we present cross-calibration results from two campaigns between all the major concurrent X-ray observatories (Chandra, Swift, Suzaku, and XMM-Newton), conducted in 2012 and 2013 on the sources 3C 273 and PKS 2155-304, and show that the differences in measured flux is within ∼10% for all instruments with respect to NuSTAR.

  4. HERO: High Energy Replicated Optics for a Hard-X-Ray Balloon Payload

    Science.gov (United States)

    Ramsey, B.; Engelhaupt, D.; Speegle, C. O.; ODell, S. L.; Austin, R. A.; Elsner, R. F.; Kolodziejczak, J. J.; Weisskopf, M. C.

    2000-01-01

    We are developing high-energy grazing-incidence replicated optics for a balloon-borne hard-x-ray telescope. When completed, the instrument will have 170 cm2 of effective collecting area at 40 keV and 130 square cm at 60 keV with <= 30 arc seconds half power diameter. This payload will offer unprecedented sensitivity in the hard-x-ray region, with around 250 microCrab sensitivity on long-duration flights and 50-100 microCrab on ultra- long-duration balloon missions The payload consists of 16 mirror modules, each with 14 nested mirrors made from a high-strength nickel alloy, and a corresponding array of 16 focal plane detectors. An engineering demonstration flight is scheduled for the Spring of 2000, using just two mirror modules each with 3 shells, above a pair of gas-scintillation-proportional counters. This flight is intended to test a newly designed gondola pointing and aspect system and the stability of the optical bench design. The first scientific flight of the full payload is scheduled for the Fall of 2002. Full details of the payload and its capabilities will be presented together with data from various mirror-module tests. If available data from the first flight will also be presented.

  5. Study on vinasse dynamics in soil using energy dispersive x-ray fluorescence with radioisotopic excitation

    Energy Technology Data Exchange (ETDEWEB)

    Simabuco, S.M. [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia; Nascimento Filho, V.F. [Sao Paulo Univ., Piracicaba, SP (Brazil). Escola Superior de Agricultura Luiz de Queiroz]|[Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)

    1994-05-01

    The distribution of S, Cl, K and Ca along the profiles of two soils of different texture (Red Yellow Podzolic and Dark Red Latosol) treated with amounts of vinasse equivalent to 4000 m{sup 3}/ha were studied using energy dispersive X-ray fluorescence, observing a significant increase in the contents of these elements. The same effect was observed for Cu, Zn, Rb and Sr contents in soils treated with vinasse as compared to the control. The concentrations of Al, Si, Ti, Mn, Fe and Zr could also be evaluated but no significant variation was observed due to the high soil initial concentrations of these elements as compared to the low concentrations in the vinasse. Annular radioactive sources of Fe-55 and Cd-109 were employed for the excitation of these elements in the soil samples, treated or not with vinasse. For the detection of the characteristic X-rays, a Si(Li) semiconductor detector was used, coupled to a multichannel emulation card inserted in a microcomputer. (author). 8 refs, 6 figs, 4 tabs.

  6. Particle size and strain broadening in energy-dispersive x-ray powder patterns

    DEFF Research Database (Denmark)

    Gerward, Leif; Mørup, Steen; Topsøe, Haldor

    1976-01-01

    An energy-dispersive x-ray method for a rapid analysis of the broadening of diffraction lines in powder patterns has been developed. Experimental results are given for magnetite powders with sizes in the range 50–200 Å and compared with the results of standard angle-dispersive diffractometry and ...... studies. The method should be of special advantage for the study of solid-state reactions and processes such as sintering. Journal of Applied Physics is copyrighted by The American Institute of Physics....... and electron microscopy. The greatest advantages of the energy-dispersive method compared with the angle-dispersive method are the absence of the Kalpha doublet, the simultaneous recording of a large part of the diffraction pattern, the fast data accumulation, and the adaptability of the technique to in situ...

  7. Transmission diffractive patterns of large microchannel plates at soft X-ray energies

    Science.gov (United States)

    Mazuritskiy, M. I.; Dabagov, S. B.; Lerer, A. M.; Dziedzic-Kocurek, K.; Sokolov, A.; Coreno, M.; Turchini, S.; D'Elia, A.; Sacchi, M.; Marcelli, A.

    2017-07-01

    In this contribution we compare experimental and theoretical diffractive patterns of Micro Channel Plates (MCPs) in transmission. We evaluate the transmission efficiency of different optical devices at different energies of the primary X-ray radiation in the normal incidence geometry. Data were collected performing angular scans of both the MCP device and of the detector in the range of a few degrees. We analyzed MCPs of 33 mm and 20 mm diameter and ∼300 μm thickness, having circular micro-channels of 3.4 μm directed normal to the MCP surface. Quite symmetric patterns of increasing complexity from high to low photon energy have been collected. Their shape and intensity are in reasonable agreement with preliminary simulations.

  8. Multiple-wave diffraction in high energy resolution back-reflecting x-ray optics.

    Science.gov (United States)

    Stetsko, Yuri P; Keister, J W; Coburn, D S; Kodituwakku, C N; Cunsolo, A; Cai, Y Q

    2011-10-07

    We have studied the effects of multiple-wave diffraction in a novel optical scheme recently published by Shvyd'ko et al. utilizing Bragg diffraction of x rays in backscattering geometry from asymmetrically cut crystals for achieving energy resolutions beyond the intrinsic width of the Bragg reflection. By numerical simulations based on dynamic x-ray diffraction and by experimentation involving two-dimensional angular scans of the back-reflecting crystal, multiple-wave diffraction was found to contribute up to several tens percent loss of efficiency but can be avoided without degrading the energy resolution of the original scheme by careful choice of azimuthal orientation of the diffracting crystal surface and by tilting of the crystal perpendicular to the dispersion plane.

  9. Multi-energy penalized maximum-likelihood reconstruction for x-ray security imaging

    Science.gov (United States)

    Politte, David G.; Lu, Jingwei; O'Sullivan, Joseph A.; Johnson, Eric; Bosch, Carl

    2017-05-01

    X-ray imaging for security screening is a challenging application that requires simultaneous satisfaction of seemingly incompatible constraints, including low cost, high throughput, and reliable detection of threats. We take a principled computational imaging approach to system design. Mathematical models of the underlying physics and a Huber-class penalty function yield a penalized maximum-likelihood problem. We extend our iterative algorithm for computing linear attenuation coefficients to use multiple energy bins in the SureScan x1000, which has an unconventional, fixed-source geometry. The goal is to maintain the spatial resolution of the single-energy reconstruction while providing information for material characterization used for detection of threats.

  10. X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fenster, A. [Univ. of Western Ontario, J.P. Robarts Institute, London, Ontario (Canada); Yaffe, M.J. [Univ. of Toronto, Depts. of Medical Biophysics and Medical Imaging, North York, Ontario (Canada)

    1995-09-01

    In this article, we briefly review the principles of x-ray imaging, consider some of its applications in medicine and describe some of the developments in this area which have taken place in Canada. X rays were first used for diagnosis and therapy in medicine almost immediately after the report of their discovery by Roentgen in 1895. X-ray imaging has remained the primary tool for the investigation of structures within the body up to the present time (Johns and Cunningham 1983). Medical x rays are produced in a vacuum tube by the electron bombardment of a metallic target. Electrons emitted from a heated cathode are accelerated through an electric field to energies of 20-150 keV (wavelength 6.2-0.83 nm) and strike a target anode. X rays appear in a spectrum of bremsstrahlung radiation with energies ranging from 0 to a value that is numerically equal to the peak voltage applied between the cathode and anode of the x-ray tube (Figure 1). In addition, where the energy of the impinging electrons exceeds the binding energy of inner atomic orbitals of the target material, electrons may be ejected from those shells. Filling of these shells by more loosely-bound electrons gives rise to x rays whose energies are equal to the difference of the binding energies of the donor and acceptor shells. The energies of these characteristic x rays are unique to the target material. Less than 1% of the energy of the incident electrons is converted to that of x rays, while the remainder is dissipated as heat in the target. For this reason, a tremendous amount of engineering has gone into the design of x-ray tubes that can yield a large fluence rate of quanta from a small effective source size, while withstanding the enormous applied heat loading (e.g. 10 kJ per exposure). Tungsten is by far the most common material used for targets in tubes for diagnostic radiology, because of its high melting point and its high atomic number; the efficiency of x-ray production is proportional to Z of the

  11. [Body composition by dual-energy x-ray absorptiometry in women with fibromyalgia].

    Science.gov (United States)

    Lobo, Márcia Maria Marques Teles; Paiva, Eduardo dos Santos; Andretta, Aline; Schieferdecker, Maria Eliana Madalozzo

    2014-01-01

    To assess body composition in women with fibromyalgia (FM) comparing to the reference value for healthy women. Cross-sectional observational analytical study, with 52 women selected with Fibromyalgia, according American College of Rheumatology (ACR, 1990) criteria. The patients were selected in Hospital de Clínicas da Universidade Federal do Paraná (HC-UFPR) and divided into two groups, 28 patients with a BMI (Body Mass Index) equal or higher (≥) than 25kg/m2 and 24 patients with BMI less or equal (≤) 24.99 kg/m2, subjected to physical examination for the count of tender points (TP) and completing the fibromyalgia impact questionnaire (FIQ). The assessment of body composition was performed by the Dual-Energy X-Ray Absorptiometry (DXA). The values of the fat mass percentage (MG %) found in the two groups were compared to the average percentage of MG by age and sex, described by Heward (2004). The mean age of the study groups was 47.8 ± 8.6 years, the FIQ score was 70.5 ± 18.6 and TP 16.2 ± 2.0. The mean BMI was 26.4 ± 4.1 kg/m2, and the amount of MG was 25.2 ± 7.8 kg and 39.5 ± 6.8%, and lean mass (LM) was 37 2 ± 3.7 kg and 60.4 ± 7.3%. In the group with BMI ≤ 25 kg/m2, the MG % was 33.8% (21.5 -42.4) and in the group with BMI ≥ 25 kg/m2 of the MG was 44.4% (37.6 -56.2). Both groups women with FM eutrophic as the overweight and obese group, presented higher reference MG% levels comparing with the standard levels for healthy women. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  12. Benchmarking transition energies and emission strengths for X-ray astrophysics with measurements at the Livermore EBITs

    Science.gov (United States)

    Hell, Natalie

    2017-03-01

    measured the energies of K α transitions in L-shell ions of Si and S at EBIT using the EBIT calorimeter spectrometer (ECS) with 4.5-5.0 eV resolution, i.e., a similar resolution to the Astro-H /Hitomi SXS soft X-ray spectrometer. While these lines will become interesting also for L-shell ions of other astrophysically abundant elements, they have been observed most prominently from L-shell ions of Si and S in the X-ray spectra of a variety of astrophysical sources. The measured line centers have an accuracy of 0.5 eV for the strong transitions and 1 eV for the weaker ones. This accuracy translates to Doppler shifts of less than 90 km s -1 , i.e., less than the calibration uncertainty of the Chandra high-energy transmission gratings. The measured line centers are identified with my own calculations with the Flexible Atomic Code (FAC) and compared to these and calculations by Palmeri et al. (2008). I demonstrate the impact of these measurements by re-evaluating Doppler shifts for the high-mass X-ray binaries Vela X-1 and Cyg X-1 with the new reference data. Using the high-resolution, imaging focusing spherical crystal spectrometer EBHiX with a quartz 101 crystal, I verified the results from the ECS measurements on K α transitions in N- through Li-like S. The measurement has a spectral resolution of better than 0.52 eV. The derived transition energies have an accuracy of 0.2 eV, corresponding to Doppler shifts of strongly blended K α spectra of M-shell Fe ions around 6.4 keV. Contributions to the 6.4 keV line complex from these ions are important for transient plasmas such as those in supernova remnants. While a simple FAC model of Cl- through F-like Fe suggested it should be possible to resolve major contributions from different charge states to this complex at a 2 eV resolution, the data did not allow us to identify any new lines, although the spectral resolution of this measurement was higher than in previous experiments. Thirdly, I measured absolute electron impact

  13. Long term variability of Cygnus X-1. VI. Energy-resolved X-ray variability 1999-2011

    Science.gov (United States)

    Grinberg, V.; Pottschmidt, K.; Böck, M.; Schmid, C.; Nowak, M. A.; Uttley, P.; Tomsick, J. A.; Rodriguez, J.; Hell, N.; Markowitz, A.; Bodaghee, A.; Cadolle Bel, M.; Rothschild, R. E.; Wilms, J.

    2014-05-01

    We present the most extensive analysis of Fourier-based X-ray timing properties of the black hole binary Cygnus X-1 to date, based on 12 years of bi-weekly monitoring with RXTE from 1999 to 2011. Our aim is a comprehensive study of timing behavior across all spectral states, including the elusive transitions and extreme hard and soft states. We discuss the dependence of the timing properties on spectral shape and photon energy, and study correlations between Fourier-frequency dependent coherence and time lags with features in the power spectra. Our main results follow. (a) The fractional rms in the 0.125-256 Hz range in different spectral states shows complex behavior that depends on the energy range considered. It reaches its maximum not in the hard state, but in the soft state in the Comptonized tail above 10 keV. (b) The shape of power spectra in hard and intermediate states and the normalization in the soft state are strongly energy-dependent in the 2.1-15 keV range. This emphasizes the need for an energy-dependent treatment of power spectra and a careful consideration of energy- and mass-scaling when comparing the variability of different source types, e.g., black hole binaries and AGN. PSDs during extremely hard and extremely soft states can be easily confused for energies above ~5 keV in the 0.125-256 Hz range. (c) The coherence between energy bands drops during transitions from the intermediate into the soft state but recovers in the soft state. (d) The time lag spectra in soft and intermediate states show distinct features at frequencies related to the frequencies of the main variability components seen in the power spectra and show the same shift to higher frequencies as the source softens. Our results constitute a template for other sources and for physical models for the origin of the X-ray variability. In particular, we discuss how the timing properties of Cyg X-1 can be used to assess the evolution of variability with spectral shape in other black

  14. High-energy X-ray optics with silicon saw-tooth refractive lenses.

    Science.gov (United States)

    Shastri, S D; Almer, J; Ribbing, C; Cederström, B

    2007-03-01

    Silicon saw-tooth refractive lenses have been in successful use for vertical focusing and collimation of high-energy X-rays (50-100 keV) at the 1-ID undulator beamline of the Advanced Photon Source. In addition to presenting an effectively parabolic thickness profile, as required for aberration-free refractive optics, these devices allow high transmission and continuous tunability in photon energy and focal length. Furthermore, the use of a single-crystal material (i.e. Si) minimizes small-angle scattering background. The focusing performance of such saw-tooth lenses, used in conjunction with the 1-ID beamline's bent double-Laue monochromator, is presented for both short ( approximately 1:0.02) and long ( approximately 1:0.6) focal-length geometries, giving line-foci in the 2 microm-25 microm width range with 81 keV X-rays. In addition, a compound focusing scheme was tested whereby the radiation intercepted by a distant short-focal-length lens is increased by having it receive a collimated beam from a nearer (upstream) lens. The collimation capabilities of Si saw-tooth lenses are also exploited to deliver enhanced throughput of a subsequently placed small-angular-acceptance high-energy-resolution post-monochromator in the 50-80 keV range. The successful use of such lenses in all these configurations establishes an important detail, that the pre-monochromator, despite being comprised of vertically reflecting bent Laue geometry crystals, can be brilliance-preserving to a very high degree.

  15. Statistical reconstruction for x-ray computed tomography using energy-integrating detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lasio, Giovanni M [Division of Medical Physics, Department of Radiation Oncology, Virginia Commonwealth University, Richmond, VA 23298 (United States); Whiting, Bruce R [Department of Radiology, Washington University, St Louis, MO 63130 (United States); Williamson, Jeffrey F [Division of Medical Physics, Department of Radiation Oncology, Virginia Commonwealth University, Richmond, VA 23298 (United States)

    2007-04-21

    Statistical image reconstruction (SR) algorithms have the potential to significantly reduce x-ray CT image artefacts because they use a more accurate model than conventional filtered backprojection and can incorporate effects such as noise, incomplete data and nonlinear detector response. Most SR algorithms assume that the CT detectors are photon-counting devices and generate Poisson-distributed signals. However, actual CT detectors integrate energy from the x-ray beam and exhibit compound Poisson-distributed signal statistics. This study presents the first assessment of the impact on image quality of the resultant mismatch between the detector and signal statistics models assumed by the sinogram data model and the reconstruction algorithm. A 2D CT projection simulator was created to generate synthetic polyenergetic transmission data assuming (i) photon-counting with simple Poisson-distributed signals and (ii) energy-weighted detection with compound Poisson-distributed signals. An alternating minimization (AM) algorithm was used to reconstruct images from the data models (i) and (ii) for a typical abdominal scan protocol with incident particle fluence levels ranging from 10{sup 5} to 1.6 x 10{sup 6} photons/detector. The images reconstructed from data models (i) and (ii) were compared by visual inspection and image-quality figures of merit. The reconstructed image quality degraded significantly when the means were mismatched from the assumed model. However, if the signal means are appropriately modified, images from data models (i) and (ii) did not differ significantly even when SNR is very low. While data-mean mismatches characteristic of the difference between particle-fluence and energy-fluence transmission can cause significant streaking and cupping artefacts, the mismatch between the actual and assumed CT detector signal statistics did not significantly degrade image quality once systematic data means mismatches were corrected.

  16. HIGH-ENERGY X-RAY PINHOLE CAMERA FOR HIGH-RESOLUTION ELECTRON BEAM SIZE MEASUREMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Yang, B.; Morgan, J.; Lee, S.H.; Shang, H.

    2017-03-25

    The Advanced Photon Source (APS) is developing a multi-bend achromat (MBA) lattice based storage ring as the next major upgrade, featuring a 20-fold reduction in emittance. Combining the reduction of beta functions, the electron beam sizes at bend magnet sources may be reduced to reach 5 – 10 µm for 10% vertical coupling. The x-ray pinhole camera currently used for beam size monitoring will not be adequate for the new task. By increasing the operating photon energy to 120 – 200 keV, the pinhole camera’s resolution is expected to reach below 4 µm. The peak height of the pinhole image will be used to monitor relative changes of the beam sizes and enable the feedback control of the emittance. We present the simulation and the design of a beam size monitor for the APS storage ring.

  17. A status report on dual energy x-ray absorptiometry quality control in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su [Dept. of Radiogic Technology, Chungbuk Health and Science University, Cheongju (Korea, Republic of); Ro, Young Hoon; Lee, In Ju; Kim, Jung Min [Dept. of Bio-convergence Engineering, Korea University Graduate School, Seoul (Korea, Republic of); Kim, Sung Su [Dept. of Healthcare Management, Cheongju University, Cheongju (Korea, Republic of); Kim, Kyoung Ah [Dept. of Diagnostic Radiology, CHA Bundang Medical Center, CHA University, Sungnam (Korea, Republic of)

    2016-12-15

    Dual-energy X-ray absorptiometry (DEXA) is the most widely used technical instrument for evaluating bone mineral content (BMC) and density (BMD) in patients of all ages. In 2016, DEXA devices operating is 5617 in Korea. In this study we investigated the quality of management practices survey for DEXA equipment and we analyzed it. We got a survey response rate of 12.6%. Accurate bone densitometry test is used data for estimation a patient's risk of fracture. However, improper bone densitometry will increase the possibility of causing a false positive. Therefore. it is essential to use the proper aids accurate bone densitomenty to be performed, and the quality control of the device to reduce the error factor of the tester through the training to reduce error for the device and the attitude.

  18. Comparison of the Bod Pod and dual energy x-ray absorptiometry in men.

    Science.gov (United States)

    Ball, Stephen D; Altena, Thomas S

    2004-06-01

    The majority of studies investigating the accuracy of the Bod Pod have compared it to hydrostatic weighing (HW), the long held, and perhaps outdated 'gold standard' method of body composition analysis. Much less research has compared the Bod Pod to dual energy x-ray absorptiometry (DXA), a technique that is becoming popular as an alternative reference method. The purpose of this study was to compare per cent fat estimates by the Bod Pod to those of DXA in a large number of men. Participants were 160 men (32 +/- 11 years). Per cent body fat was estimated to be 19.4 +/- 6.8 and 21.6 +/- 8.4 for DXA and the Bod Pod, respectively. Although the two methods were highly correlated (0.94), the mean difference of 2.2% was significant (p Bod Pod, DXA), differences between methods exist and the determination of body composition is at best, an estimation.

  19. Anthropometrics and body composition by dual energy X-ray in children of obese women

    DEFF Research Database (Denmark)

    Tanvig, Mette; Vinter, Christina A; Jørgensen, Jan S

    2014-01-01

    , coaching and exercise. The trial was completed by 301 women who were eligible for follow-up. In addition, to the children from the RCT, a group of children born to women with a normal BMI were included as a reference group. At 2.8 (range 2.5-3.2) years, anthropometrics were measured in 157 children...... of the RCT mothers and in 97 reference group children with Body Mass Index (BMI) Z-score as a primary outcome. Body composition was estimated by Dual Energy X-ray (DEXA) in 123 successful scans out of 147 (84%). RESULTS: No differences between randomized groups were seen in mean (95% C.I.) BMI Z...

  20. Stability of semiconducting transition metal dichalcogenides irradiated by soft X-rays and low energy electrons

    Science.gov (United States)

    Walker, Roger C.; Bhimanapati, Ganesh R.; Shi, Tan; Zhang, Kehao; Eichfeld, Sarah M.; Jovanovic, Igor; Robinson, Joshua A.

    2017-04-01

    Semiconducting two-dimensional materials (2DMs) such as molybdenum disulfide and tungsten diselenide have attracted significant attention due to their unique electronic properties. Understanding their nanoscale radiation tolerance is needed for developing radiation-hardened nanoelectronics. Here, we report that the XPS environment of soft X-ray (E = 1.486 keV) exposure in a vacuum combined with a low energy electron flood gun leads to charge accumulation in the 2D layers over time, with little impact on layer chemistry. Additionally, the charging that induced the 2DM/substrate heterostructure depends more on the growth technique, the size of as-grown domains, and the surface coverage of the 2DM than the conductivity of the substrate. Charging is minimized for the combination of a continuous 2DM film and strong coupling between the 2DM and the substrate.

  1. Direct Structural Observation of a Molecular Junction by High-Energy X-ray Reflectometry

    Energy Technology Data Exchange (ETDEWEB)

    Lefenfeld,M.; Baumert, J.; Sloutskin, E.; Kuzmenko, I.; Pershan, P.; Deutsch, M.; Nuckolls, C.; Ocko, B.

    2006-01-01

    We report a direct angstrom resolution measurement of the structure of a molecular-size electronic junction comprising a single (or a double) layer of alkyl-thiol and alkyl-silane molecules at the buried interface between solid silicon and liquid mercury. The high-energy synchrotron x-ray measurements reveal densely packed layers comprising roughly interface-normal molecule . The monolayer's thickness is found to be 3-4 Angstroms larger than that of similar layers at the free surfaces of both mercury and silicon. The origins of this and the other unusual features detected are discussed in this article. Measurements of the bilayer junction with an applied potential did not show visible changes in the surface normal structure.

  2. Neonatal anthropometrics and body composition in obese children investigated by dual energy X-ray absorptiometry

    DEFF Research Database (Denmark)

    Lausten-Thomsen, Ulrik; Nielsen, Tenna Ruest Haarmark; Thagaard, Ida Näslund

    2014-01-01

    index (BFMI), and fat free mass index (FFMI) in obese children and the preceding in utero conditions expressed by birth weight, birth length, and birth weight for gestational age. The study cohort consisted of 776 obese Danish children (median age 11.6 years, range 3.6-17.9) with a mean Body Mass Index......UNLABELLED: Epidemiological and animal studies have suggested an effect of the intrauterine milieu upon the development of childhood obesity. This study investigates the relationship between body composition measured by dual energy X-ray absorptiometry expressed as body fat percent, body fat mass...... obesity treatment to be significantly correlated with both birth weight and birth weight for gestational age. CONCLUSION: These results indicate a prenatal influence upon childhood obesity. Although there are currently no sufficient data to suggest any recommendations to pregnant women, it is possible...

  3. Investigation of gas generation in regenerative fuel cells by low-energy X-rays

    Science.gov (United States)

    Selamet, Omer Faruk; Deevanhxay, Phengxay; Tsushima, Shohji; Hirai, Shuichiro

    2015-11-01

    Gas generation and discharge behaviors in an operating regenerative fuel cell (RFC) are investigated using low-energy X-ray radiography. In situ visualization at high spatial and temporal resolution reveal dynamic and inhomogeneous behaviors of the gas generation in the membrane electrode assembly (MEA) in the RFC. Temporal and spatial variation of the gas thickness in the MEA is quantitatively discussed and shows an intermittent and periodic discharge processes of the gas generated by electrolysis, suggesting that the reaction sites in the catalyst layer and the discharging path of gas bubbles are well established in the MEA for the electrolysis. Larger gas accumulation and discharge in the gas diffusion layer (GDL) under the ribs are identified in comparison with those under the channels, which is attributed to the relatively longer path for accumulated gas under the ribs to be discharged into the flow channels.

  4. The influence of an extrapolation chamber over the low energy X-ray beam radiation field

    Energy Technology Data Exchange (ETDEWEB)

    Tanuri de F, M. T.; Da Silva, T. A., E-mail: mttf@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    The extrapolation chambers are detectors whose sensitive volume can be modified by changing the distance between the electrodes and has been widely used for beta particles primary measurement system. In this work, was performed a PTW 23392 extrapolation chamber Monte Carlo simulation, by mean the MCNPX code. Although the sensitive volume of an extrapolation chamber can be reduced to very small size, their packaging is large enough to modify the radiation field and change the absorbed dose measurements values. Experiments were performed to calculate correction factors for this purpose. The validation of the Monte Carlo model was done by comparing the spectra obtained with a CdTe detector according to the ISO 4037 criteria. Agreements smaller than 5% for half value layers, 10% for spectral resolution and 1% for mean energy, were found. It was verified that the correction factors are dependent of the X-ray beam quality. (Author)

  5. Pediatric body composition analysis with dual-energy X-ray absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Helba, Maura; Binkovitz, Larry A. [Nationwide Children' s Hospital, Department of Radiology, Columbus, OH (United States)

    2009-07-15

    Pediatric applications of body composition analysis (BCA) have become of increased interest to pediatricians and other specialists. With the increasing prevalence of morbid obesity and with an increased awareness of anorexia nervosa, pediatric specialists are utilizing BCA data to help identify, treat, and prevent these conditions. Dual-energy X-ray absorptiometry (DXA) can be used to determine the fat mass (FM) and lean tissue mass (LTM), as well as bone mineral content (BMC). Among the readily available BCA techniques, DXA is the most widely used and it has the additional benefit of precisely quantifying regional FM and LTM. This review evaluates the strengths and limitations of DXA as a pediatric BCA method and considers the utilization of DXA to identify trends and variations in FM and LTM measurements in obese and anorexic children. (orig.)

  6. Measurement of the Energy and High-Pressure Dependence of X-ray-Induced Decomposition of Crystalline Strontium Oxalate

    Energy Technology Data Exchange (ETDEWEB)

    Goldberger, David [High-Pressure; Evlyukhin, Egor [High-Pressure; Cifligu, Petrika [High-Pressure; Wang, Yonggang [HPCAT,; Pravica, Michael [High-Pressure

    2017-09-18

    We report measurements of the X-ray-induced decomposition of crystalline strontium oxalate (SrC2O4) as a function of energy and high pressure in two separate experiments. SrC2O4 at ambient conditions was irradiated with monochromatic synchrotron X-rays ranging in energy from 15 to 28 keV. A broad resonance of the decomposition yield was observed with a clear maximum when irradiating with ~20 keV X-rays and ambient pressure. Little or no decomposition was observed at 15 keV, which is below the Sr K-shell energy of 16.12 keV, suggesting that excitation of core electrons may play an important role in the destabilization of the C2O42– anion. A second experiment was performed to investigate the high-pressure dependence of the X-ray-induced decomposition of strontium oxalate at fixed energy. SrC2O4 was compressed in a diamond anvil cell (DAC) in the pressure range from 0 to 7.6 GPa with 1 GPa increments and irradiated in situ with 20 keV X-rays. A marked pressure dependence of the decomposition yield of SrC2O4 was observed with a decomposition yield maximum at around 1 GPa, suggesting that different crystal structures of the material play an important role in the decomposition process. This may be due in part to a phase transition observed near this pressure.

  7. Laboratory-based x-ray reflectometer for multilayer characterization in the 15–150 keV energy band

    Energy Technology Data Exchange (ETDEWEB)

    Windt, David L., E-mail: davidwindt@gmail.com [Reflective X-ray Optics LLC, 1361 Amsterdam Ave., Suite 3B, New York, New York 10027 (United States)

    2015-04-15

    A laboratory-based X-ray reflectometer has been developed to measure the performance of hard X-ray multilayer coatings at their operational X-ray energies and incidence angles. The instrument uses a sealed-tube X-ray source with a tungsten anode that can operate up to 160 kV to provide usable radiation in the 15–150 keV energy band. Two sets of adjustable tungsten carbide slit assemblies, spaced 4.1 m apart, are used to produce a low-divergence white beam, typically set to 40 μm × 800 μm in size at the sample. Multilayer coatings under test are held flat using a vacuum chuck and are mounted at the center of a high-resolution goniometer used for precise angular positioning of the sample and detector; additionally, motorized linear stages provide both vertical and horizontal adjustments of the sample position relative to the incident beam. A CdTe energy-sensitive detector, located behind a third adjustable slit, is used in conjunction with pulse-shaping electronics and a multi-channel analyzer to capture both the incident and reflected spectra; the absolute reflectance of the coating under test is computed as the ratio of the two spectra. The instrument’s design, construction, and operation are described in detail, and example results are presented obtained with both periodic, narrow-band and depth-graded, wide-band hard X-ray multilayer coatings.

  8. MEASUREMENT OF THE HIGH ENERGY COMPONENT OF THE X-RAY SPECTRA INTHE VENUS ECR ION SOURCE

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, Daniela; Benitez, Janilee Y.; Lyneis, Claude M.; Todd,Damon S.; Ropponen,Tommi; Ropponen,Janne; Koivisto, Hannu; Gammino, Santo

    2007-11-15

    High performance electron cyclotron resonance (ECR) ion sources, such as VENUS (Versatile ECR for Nuclear Science), produce large amounts of x-rays. By studying their energy spectra, conclusions can be drawn about the electron heating process and the electron confinement. In addition, the bremsstrahlung from the plasma chamber is partly absorbed by the cold mass of the superconducting magnet adding an extra heat load to the cryostat. Germanium or NaI detectors are generally used for x-ray measurements. Due to the high x-ray flux from the source, the experimental set-up to measure bremsstrahlung spectra from ECR ion sources is somewhat different than for the traditional nuclear physics measurements these detectors are generally used for. In particular the collimation and background shielding can be problematic. In this paper we will discuss the experimental set-up for such a measurement, the energy calibration and background reduction, the correction for detector efficiency, the shielding of the detector and collimation of the x-ray flux. We will present x-ray energy spectra and cryostat heating rates in dependence of various ion source parameters such as confinement fields, minimum B-field, rf power and heating frequency.

  9. Energy spectrum measurement of high power and high energy(6 and 9 MeV) pulsed x-ray source for industrial use

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Hiroyuki [Hitachi, Ltd. Power Systems Company, Ibaraki (Japan); Murata, Isao [Graduate School of Engineering, Osaka University, Osaka (Japan)

    2016-06-15

    Industrial X-ray CT system is normally applied to non-destructive testing (NDT) for industrial product made from metal. Furthermore there are some special CT systems, which have an ability to inspect nuclear fuel assemblies or rocket motors, using high power and high energy (more than 6 MeV) pulsed X-ray source. In these case, pulsed X-ray are produced by the electron linear accelerator, and a huge number of photons with a wide energy spectrum are produced within a very short period. Consequently, it is difficult to measure the X-ray energy spectrum for such accelerator-based X-ray sources using simple spectrometry. Due to this difficulty, unexpected images and artifacts which lead to incorrect density information and dimensions of specimens cannot be avoided in CT images. For getting highly precise CT images, it is important to know the precise energy spectrum of emitted X-rays. In order to realize it we investigated a new approach utilizing the Bayesian estimation method combined with an attenuation curve measurement using step shaped attenuation material. This method was validated by precise measurement of energy spectrum from a 1 MeV electron accelerator. In this study, to extend the applicable X-ray energy range we tried to measure energy spectra of X-ray sources from 6 and 9 MeV linear accelerators by using the recently developed method. In this study, an attenuation curves are measured by using a step-shaped attenuation materials of aluminum and steel individually, and the each X-ray spectrum is reconstructed from the measured attenuation curve by the spectrum type Bayesian estimation method. The obtained result shows good agreement with simulated spectra, and the presently developed technique is adaptable for high energy X-ray source more than 6 MeV.

  10. Signal to noise ratio of energy selective x-ray photon counting systems with pileup.

    Science.gov (United States)

    Alvarez, Robert E

    2014-11-01

    To derive fundamental limits on the effect of pulse pileup and quantum noise in photon counting detectors on the signal to noise ratio (SNR) and noise variance of energy selective x-ray imaging systems. An idealized model of the response of counting detectors to pulse pileup is used. The model assumes a nonparalyzable response and delta function pulse shape. The model is used to derive analytical formulas for the noise and energy spectrum of the recorded photons with pulse pileup. These formulas are first verified with a Monte Carlo simulation. They are then used with a method introduced in a previous paper [R. E. Alvarez, "Near optimal energy selective x-ray imaging system performance with simple detectors," Med. Phys. 37, 822-841 (2010)] to compare the signal to noise ratio with pileup to the ideal SNR with perfect energy resolution. Detectors studied include photon counting detectors with pulse height analysis (PHA), detectors that simultaneously measure the number of photons and the integrated energy (NQ detector), and conventional energy integrating and photon counting detectors. The increase in the A-vector variance with dead time is also computed and compared to the Monte Carlo results. A formula for the covariance of the NQ detector is developed. The validity of the constant covariance approximation to the Cramèr-Rao lower bound (CRLB) for larger counts is tested. The SNR becomes smaller than the conventional energy integrating detector (Q) SNR for 0.52, 0.65, and 0.78 expected number photons per dead time for counting (N), two, and four bin PHA detectors, respectively. The NQ detector SNR is always larger than the N and Q SNR but only marginally so for larger dead times. Its noise variance increases by a factor of approximately 3 and 5 for the A1 and A2 components as the dead time parameter increases from 0 to 0.8 photons per dead time. With four bin PHA data, the increase in variance is approximately 2 and 4 times. The constant covariance approximation

  11. Metrology for the Development of High Energy X-Ray Optics

    Science.gov (United States)

    Gubarev, Mikhail; Ramsey, Brian; Engelhaupt, Darell; Dpeegle, Chet

    2005-01-01

    We are developing grazing incidence x-ray optics for a balloon-borne hard-x-ray telescope (HERO). The instrument will have 200 sq cm effective collecting area at 40 keV and an angular resolution goal of 15 arcsec. The HERO mirror shells are fabricated using electroform-nickel replication off super-polished cylindrical mandrels. The angular resolution goal puts stringent requirements on the quality of x-ray mirrors and, hence, on mandrel quality. We used metrology in an iterative approach to monitor and refine the x- ray mirror fabrication process. Comparison of surface figure and microroughness measurements of the mandrel and the shells will be presented together with results from x-ray tests.

  12. Methodology for calibration of ionization chambers for X-ray of low energy in absorbed dose to water

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, C.T.; Vivolo, V.; Potiens, M.P.A., E-mail: camila_fmedica@hotmail.com [Instituto de Pesquisas Energeticas e Nucleres (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The beams of low energy X-ray (10 to 150 kV) are used in several places in the world to treat a wide variety of surface disorders, and between these malignancies. As in Brazil, at this moment, there is no calibration laboratory providing the control service or calibration of parallel plate ionization chambers, the aim of this project was to establish a methodology for calibration of this kind of ionization chambers at low energy X-ray beams in terms of absorbed dose to water using simulators in the LCI. (author)

  13. A portable Compton spectrometer for clinical X-ray beams in the energy range 20-150 keV

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, A.A. [Departamento de Fisica, Pontificia Universidade Catolica de Sao Paulo (PUC-SP), Rua Marques de Paranagua, 111-01303-050 Sao Paulo, SP (Brazil); Linke, A. [Instituto de Fisica-Universidade de Sao Paulo, Rua do Matao, 187-Travessa R-05508-900 Sao Paulo, SP (Brazil); Yoshimura, E.M., E-mail: e.yoshimura@dfn.if.usp.b [Instituto de Fisica-Universidade de Sao Paulo, Rua do Matao, 187-Travessa R-05508-900 Sao Paulo, SP (Brazil); Terini, R.A., E-mail: rterini@pucsp.b [Departamento de Fisica, Pontificia Universidade Catolica de Sao Paulo (PUC-SP), Rua Marques de Paranagua, 111-01303-050 Sao Paulo, SP (Brazil); Instituto de Eletrotecnica e Energia-Universidade de Sao Paulo, Av. Prof. Luciano Gualberto, 1289-05508-900 Sao Paulo, SP (Brazil); Herdade, S.B., E-mail: sherdade@iee.usp.b [Instituto de Fisica-Universidade de Sao Paulo, Rua do Matao, 187-Travessa R-05508-900 Sao Paulo, SP (Brazil); Instituto de Eletrotecnica e Energia-Universidade de Sao Paulo, Av. Prof. Luciano Gualberto, 1289-05508-900 Sao Paulo, SP (Brazil)

    2011-02-15

    Primary beam spectra were obtained for an X-ray industrial equipment (40-150 kV), and for a clinical mammography apparatus (25-35 kV) from beams scattered at angles close to 90{sup o}, measured with a CdTe Compton spectrometer. Actual scattering angles were determined from the Compton energy shift of characteristic X-rays or spectra end-point energy. Evaluated contribution of coherent scattering amounts to more than 15% of fluence in mammographic beams. This technique can be used in clinical environments.

  14. The application of a drift multiwire proportional counter to the imaging of low energy X-rays

    Science.gov (United States)

    Ku, W. H.-M.; Reid, P. B.; Long, K. S.; Novick, R.

    1978-01-01

    A 75 mm x 75 mm multiwire proportional counter (MWPC) with a 1 micron polypropylene window has been built to map low energy X-rays. The MWPC is constructed with a large drift region which allows us to use the center-of-gravity technique to improve the counter's efficiency and position resolution. Using 330 torr of propane as the gas fill and an anode plane composed of 20 micron diameter Au-plated tungsten wire spaced 1 mm apart, a position resolution of better than 240 microns (FWHM) in two orthogonal directions at an X-ray energy of 0.94 keV has been achieved.

  15. A large-volume gas cell for high-energy X-ray reflectivity investigations of interfaces under pressure.

    Science.gov (United States)

    Venturini, Federica; Schöder, Sebastian; Kuhs, Werner F; Honkimäki, Veijo; Melesi, Louis; Reichert, Harald; Schober, Helmut; Thomas, Frederic

    2011-03-01

    A cell for the investigation of interfaces under pressure is presented. Given the pressure and temperature specifications of the cell, P ≤ 100 bar and 253 K ≤ T ≤ 323 K, respectively, high-energy X-rays are required to penetrate the thick Al(2)O(3) windows. The CH(4)(gas)/H(2)O(liquid) interface has been chosen to test the performance of the new device. The measured dynamic range of the high-energy X-ray reflectivity data exceeds 10(-8), thereby demonstrating the validity of the entire experimental set-up.

  16. A rotational and axial motion system load frame insert for in situ high energy x-ray studies

    Energy Technology Data Exchange (ETDEWEB)

    Shade, Paul A., E-mail: paul.shade.1@us.af.mil; Schuren, Jay C.; Turner, Todd J. [Materials and Manufacturing Directorate, Air Force Research Laboratory, Wright-Patterson AFB, Ohio 45433 (United States); Blank, Basil [PulseRay, Beaver Dams, New York 14812 (United States); Kenesei, Peter; Goetze, Kurt; Lienert, Ulrich; Almer, Jonathan [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Suter, Robert M. [Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 (United States); Bernier, Joel V.; Li, Shiu Fai [Engineering Directorate, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Lind, Jonathan [Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 (United States); Engineering Directorate, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2015-09-15

    High energy x-ray characterization methods hold great potential for gaining insight into the behavior of materials and providing comparison datasets for the validation and development of mesoscale modeling tools. A suite of techniques have been developed by the x-ray community for characterizing the 3D structure and micromechanical state of polycrystalline materials; however, combining these techniques with in situ mechanical testing under well characterized and controlled boundary conditions has been challenging due to experimental design requirements, which demand new high-precision hardware as well as access to high-energy x-ray beamlines. We describe the design and performance of a load frame insert with a rotational and axial motion system that has been developed to meet these requirements. An example dataset from a deforming titanium alloy demonstrates the new capability.

  17. Structural analysis of polymer thin films using GISAXS in the tender X-ray region: Concept and design of GISAXS experiments using the tender X-ray energy at BL-15A2 at the Photon Factory

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, H., E-mail: takagih@post.kek.jp; Igarashi, N.; Mori, T.; Saijo, S.; Nagatani, Y.; Shimizu, N. [Photon Factory, Institute of Materials Structure Science, High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Ohta, H. [Mitsubishi Electric System & Service Co., Ltd, Accelerator Engineering Center, 2-8- 8 Umezono, Tsukuba, Ibaraki 305-0045 (Japan); Yamamoto, K. [Graduate School of Engineering, Department of Materials Science & Technology, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555 (Japan)

    2016-10-14

    If small angle X-ray scattering (SAXS) utilizing the soft X-ray region is available, advanced and unique experiments, which differ from traditional SAXS methods, can be realized. For example, grazing-incidence small angle X-ray scattering (GISAXS) using hard X-ray is a powerful tool for understanding the nanostructure in both vertical and lateral directions of thin films, while GISAXS utilizing the tender X-ray region (SX-GISAXS) enables depth-resolved analysis as well as a standard GISAXS analysis in thin films. Thus, at BL-15A2 at the Photon Factory, a dedicated diffractometer for SX-GISAXS (above 2.1 keV) was constructed. This diffractometer is composed of four vacuum chambers and can be converted into the vacuum state from the sample chamber in front of the detector surface. Diffractions are clearly observed until 12th peak when measuring collagen by SAXS with an X-ray energy of 2.40 keV and a camera length of 825 mm. Additionally, we conducted the model experiment using SX-GISAXS with an X-ray energy of 2.40 keV to confirm that a poly(methyl methacrylate)-poly(n-butyl acrylate) block copolymer thin film has a microphase-separated structure in the thin film, which is composed of lamellae aligned both parallel and perpendicular to the substrate surface. Similarly, in a polystyrene-poly(methyl methacrylate) block copolymer thin film, SX-GISAXS with 3.60 keV and 5.73 keV revealed that hexagonally packed cylinders are aligned parallel to the substrate surface. The incident angle dependence of the first order peak position of the q{sub z} direction obtained from experiments at various incident X-ray energies agrees very well with the theoretical one calculated from the distorted wave Born approximation.

  18. High energy x-ray and neutron studies of disordered energy-related materials at extreme conditions

    Energy Technology Data Exchange (ETDEWEB)

    Parise, John [Stony Brook Univ., NY (United States)

    2016-05-16

    The fundamental scientific accomplishments are: (1) advances in a general description of the liquid state by employing structural models constrained by measurements to interpret experimental results and extend them to liquids in general, with special emphasis on (2) The structure of the high-temperature crystal and molten UO2 and 3) water. Specifically, samples of UO2 and water were probed using high-energy x-rays at the Advanced Photon Source. The high Z of UO2, and the 2-3mm diameter droplet shape of the molten sample, means that >100keV X-rays are required to minimize absorption and multiple scattering, which can distort the measured structure factor. A high flux of x-rays is also required to obtain sufficient statistical accuracy in short (a few seconds) measurement times. The scattered x-ray data were analyzed and pair distribution functions, extracted that characterize the local and long-range atomic structure of the material. The measurements of the hot UO2 solid show a substantial increase in oxygen disorder and, upon melting, the average U-O coordination was found to decrease from 8 to 6.7±0.5. The research incorporated development of diffraction techniques, sample environment optimization and state-of-the-art simulation techniques. The symbiotic nature of the advances in simulation and experiment allowed for a more focused and informed development of future experiments, effective use of expensive beam time and generated new research agendas for the growing number of research groups, within the US and internationally, that focus on the structure of liquids. Molecular dynamics (MD) provided detailed information when combined with high-quality XN data including addressing key issues in liquids; the relationship between cooling path, structure and fictive temperature, and the trade-offs between network over connectedness in liquids containing low-coordination cations.

  19. New contrast media designed for x-ray energy subtraction imaging in digital mammography.

    Science.gov (United States)

    Lawaczeck, Rüdiger; Diekmann, Felix; Diekmann, Susanne; Hamm, Bernd; Bick, Ulrich; Press, Wolf-Rüdiger; Schirmer, Heiko; Schön, Katja; Weinmann, Hanns-Joachim

    2003-09-01

    In contrast-enhanced dual-energy subtraction imaging 2 images acquired postcontrast media administration at different energies are subtracted to highlight structures hidden in the absence of contrast media. X-ray spectra of the newly developed digital full-field mammography units (GE Senographe 2000 D) are dominated by the emission lines of the Mo or Rh anodes. The K-edge of Zirconium (Zr) is flanked by these 2 emission lines. Thus, the attenuation of Zr should experience a pronounced change of attenuation in parallel with a change of anodes. Under clinically relevant conditions, the contrasting behavior of Zr should be compared with that of other elements having K-edge energies outside the window spanned by the 2 anode emission lines. Solutions containing the contrasting elements Br, Y, Zr, I, and Gd were investigated for dual-energy subtraction in digital mammography with the 2 anode/filter settings (Mo/Mo and Rh/Rh). These solutions were investigated in phantom studies in the energy range conventionally used in mammography. Additionally, the contrasting behavior of Zr and I was compared in an in vivo study in rats. The sweeping over the K-edge by alternating between the Mo and Rh anodes increases the detection of Zr in energy subtraction imaging at constant high voltage. This procedure does not lead to sufficient contrast enhancement for iodine-based contrast media which become detectable by increasing the high voltage to 40-49 kV. The instrumental and physical data outlined predestine Zr as contrasting element with a high potential for energy subtraction imaging in digital mammography in the energy range conventionally applied.

  20. ERICA: an energy resolving photon counting readout ASIC for X-ray in-line cameras

    Science.gov (United States)

    Macias-Montero, J.-G.; Sarraj, M.; Chmeissani, M.; Moore, T.; Casanova, R.; Martinez, R.; Puigdengoles, C.; Prats, X.; Kolstein, M.

    2016-12-01

    We present ERICA (Energy Resolving Inline X-ray Camera) a photon-counting readout ASIC, with 6 energy bins. The ASIC is composed of a matrix of 8 × 20 pixels controlled by a global digital controller and biased with 7 independent digital to analog converters (DACs) and a band-gap current reference. The pixel analog front-end includes a charge sensitive amplifier with 16 mV/ke- gain and dynamic range of 45 ke-. ERICA has programmable pulse width, an adjustable constant current feedback resistor, a linear test pulse generator, and six discriminators with 6-bit local threshold adjustment. The pixel digital back-end includes the digital controller, 8 counters of 8-bit depth, half-full buffer flag for any of the 8 counters, a 74-bit shadow/shift register, a 74-bit configuration latch, and charge sharing compensation processing to perform the energy classification and counting operations of every detected photon in 1 μ s. The pixel size is 330 μm × 330 μm and its average consumption is 150 μW. Implemented in TSMC 0.25 μm CMOS process, the ASIC pixel's equivalent noise charge (ENC) is 90 e- RMS connected to a 1 mm thickness matching CdTe detector biased at -300 V with a total leakage current of 20 nA.

  1. Alignment, Assembly and Testing of High Energy X-Ray Optics

    Science.gov (United States)

    Gubarev, Mikhail; Ramsey, Brian

    2005-01-01

    We are developing grazing-incidence x-ray imaging optics for a balloon-borne hard x-ray telescope (HERO). The HERO payload, scheduled for launch in May 2005, currently consists of 8 mirror modules each containing 12 mirror shells fabricated using electroform-nickel replication off super-polished cylindrical mandrels. An optical system developed for aligning and assembling the shells in the modules will be described. Sources for systematic errors associated with this process will be discussed and results from on-ground x-ray testing of each module will be presented.

  2. Quantitative determination on heavy metals in different stages of wine production by Total Reflection X-ray Fluorescence and Energy Dispersive X-ray Fluorescence: Comparison on two vineyards

    Energy Technology Data Exchange (ETDEWEB)

    Pessanha, Sofia [Centro Fisica Atomica, Departamento de Fisica, Faculdade de Ciencias, Universidade de Lisboa, Av. Prof. Gama Pinto, 2, 1649-003 Lisboa (Portugal); Carvalho, Maria Luisa, E-mail: luisa@cii.fc.ul.p [Centro Fisica Atomica, Departamento de Fisica, Faculdade de Ciencias, Universidade de Lisboa, Av. Prof. Gama Pinto, 2, 1649-003 Lisboa (Portugal); Becker, Maria; Bohlen, Alex von [Institute for analytical Sciences, Bunsen-Kirchhoff-Str. 11, 44139 Dortmund (Germany)

    2010-06-15

    The purpose of this study is to determine the elemental content, namely heavy metals, of samples of vine-leaves, grapes must and wine. In order to assess the influence of the vineyard age on the elemental content throughout the several stages of wine production, elemental determinations of trace elements were made on products obtained from two vineyards aged 6 and 14 years from Douro region. The elemental content of vine-leaves and grapes was determined by Energy Dispersive X-Ray Fluorescence (EDXRF), while analysis of the must and wine was performed by Total Reflection X-ray Fluorescence (TXRF). Almost all elements present in wine and must samples did not exceed the recommended values found in literature for wine. Bromine was present in the 6 years old wine in a concentration 1 order of magnitude greater than what is usually detected. The Cu content in vine-leaves from the older vineyard was found to be extremely high probably due to excessive use of Cu-based fungicides to control vine downy mildew. Higher Cu content was also detected in grapes although not so pronounced. Concerning the wine a slightly higher level was detected on the older vineyard, even so not exceeding the recommended value.

  3. Final Report on Developing Microstructure-Property Correlation in Reactor Materials using in situ High-Energy X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Li, Meimei [Argonne National Lab. (ANL), Argonne, IL (United States); Almer, Jonathan D. [Argonne National Lab. (ANL), Argonne, IL (United States); Yang, Yong [Univ. of Florida, Gainesville, FL (United States); Tan, Lizhen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-01-01

    This report provides a summary of research activities on understanding microstructure – property correlation in reactor materials using in situ high-energy X-rays. The report is a Level 2 deliverable in FY16 (M2CA-13-IL-AN_-0403-0111), under the Work Package CA-13-IL-AN_- 0403-01, “Microstructure-Property Correlation in Reactor Materials using in situ High Energy Xrays”, as part of the DOE-NE NEET Program. The objective of this project is to demonstrate the application of in situ high energy X-ray measurements of nuclear reactor materials under thermal-mechanical loading, to understand their microstructure-property relationships. The gained knowledge is expected to enable accurate predictions of mechanical performance of these materials subjected to extreme environments, and to further facilitate development of advanced reactor materials. The report provides detailed description of the in situ X-ray Radiated Materials (iRadMat) apparatus designed to interface with a servo-hydraulic load frame at beamline 1-ID at the Advanced Photon Source. This new capability allows in situ studies of radioactive specimens subject to thermal-mechanical loading using a suite of high-energy X-ray scattering and imaging techniques. We conducted several case studies using the iRadMat to obtain a better understanding of deformation and fracture mechanisms of irradiated materials. In situ X-ray measurements on neutron-irradiated pure metal and model alloy and several representative reactor materials, e.g. pure Fe, Fe-9Cr model alloy, 316 SS, HT-UPS, and duplex cast austenitic stainless steels (CASS) CF-8 were performed under tensile loading at temperatures of 20-400°C in vacuum. A combination of wide-angle X-ray scattering (WAXS), small-angle X-ray scattering (SAXS), and imaging techniques were utilized to interrogate microstructure at different length scales in real time while the specimen was subject to thermal-mechanical loading. In addition, in situ X-ray studies were

  4. Energy-dispersive X-ray emission spectroscopy using an X-ray free-electron laser in a shot-by-shot mode

    Science.gov (United States)

    Alonso-Mori, Roberto; Kern, Jan; Gildea, Richard J.; Sokaras, Dimosthenis; Weng, Tsu-Chien; Lassalle-Kaiser, Benedikt; Tran, Rosalie; Hattne, Johan; Laksmono, Hartawan; Hellmich, Julia; Glöckner, Carina; Echols, Nathaniel; Sierra, Raymond G.; Schafer, Donald W.; Sellberg, Jonas; Kenney, Christopher; Herbst, Ryan; Pines, Jack; Hart, Philip; Herrmann, Sven; Grosse-Kunstleve, Ralf W.; Latimer, Matthew J.; Fry, Alan R.; Messerschmidt, Marc M.; Miahnahri, Alan; Seibert, M. Marvin; Zwart, Petrus H.; White, William E.; Adams, Paul D.; Bogan, Michael J.; Boutet, Sébastien; Williams, Garth J.; Zouni, Athina; Messinger, Johannes; Glatzel, Pieter; Sauter, Nicholas K.; Yachandra, Vittal K.; Yano, Junko; Bergmann, Uwe

    2012-01-01

    The ultrabright femtosecond X-ray pulses provided by X-ray free-electron lasers open capabilities for studying the structure and dynamics of a wide variety of systems beyond what is possible with synchrotron sources. Recently, this “probe-before-destroy” approach has been demonstrated for atomic structure determination by serial X-ray diffraction of microcrystals. There has been the question whether a similar approach can be extended to probe the local electronic structure by X-ray spectroscopy. To address this, we have carried out femtosecond X-ray emission spectroscopy (XES) at the Linac Coherent Light Source using redox-active Mn complexes. XES probes the charge and spin states as well as the ligand environment, critical for understanding the functional role of redox-active metal sites. Kβ1,3 XES spectra of MnII and Mn2III,IV complexes at room temperature were collected using a wavelength dispersive spectrometer and femtosecond X-ray pulses with an individual dose of up to >100 MGy. The spectra were found in agreement with undamaged spectra collected at low dose using synchrotron radiation. Our results demonstrate that the intact electronic structure of redox active transition metal compounds in different oxidation states can be characterized with this shot-by-shot method. This opens the door for studying the chemical dynamics of metal catalytic sites by following reactions under functional conditions. The technique can be combined with X-ray diffraction to simultaneously obtain the geometric structure of the overall protein and the local chemistry of active metal sites and is expected to prove valuable for understanding the mechanism of important metalloproteins, such as photosystem II. PMID:23129631

  5. Deterministic Computer-Controlled Polishing Process for High-Energy X-Ray Optics

    Science.gov (United States)

    Khan, Gufran S.; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian

    2010-01-01

    A deterministic computer-controlled polishing process for large X-ray mirror mandrels is presented. Using tool s influence function and material removal rate extracted from polishing experiments, design considerations of polishing laps and optimized operating parameters are discussed

  6. Correlation of Thermally Induced Pores with Microstructural Features Using High Energy X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Menasche, David B.; Shade, Paul A.; Lind, Jonathan F.; Li, Shiu Fai; Kenesei, Peter; Schuren, Jay C.; Suter, Robert M.

    2016-11-01

    Combined application of a near-field High Energy Diffraction Microscopy measurement of crystal lattice orientation fields and a tomographic measurement of pore distributions in a sintered nickel-based superalloy sample allows pore locations to be correlated with microstructural features. Measurements were carried out at the Advanced Photon Source beamline 1-ID using an X-ray energy of 65 keV for each of the measurement modes. The nickel superalloy sample was prepared in such a way as to generate significant thermally induced porosity. A three-dimensionally resolved orientation map is directly overlaid with the tomographically determined pore map through a careful registration procedure. The data are shown to reliably reproduce the expected correlations between specific microstructural features (triple lines and quadruple nodes) and pore positions. With the statistics afforded by the 3D data set, we conclude that within statistical limits, pore formation does not depend on the relative orientations of the grains. The experimental procedures and analysis tools illustrated are being applied to a variety of materials problems in which local heterogeneities can affect materials properties.

  7. Threat detection of liquid explosives and precursors from their x-ray scattering pattern using energy dispersive detector technology

    DEFF Research Database (Denmark)

    Kehres, Jan; Olsen, Ulrik Lund; Lyksborg, Mark

    2017-01-01

    Energy dispersive X-ray diffraction (EDXRD) can be applied for identification of liquid threats in luggage scanning in security applications. To define the instrumental design, the framework for data reduction and analysis and test the performance of the threat detection in various scenarios...

  8. Energy-Dispersive X-Ray Diffraction Studies of the Texture in Cold-Rolled Alpha-Beta Brass

    DEFF Research Database (Denmark)

    Szpunar, J.; Gerward, L.

    1980-01-01

    It is shown that energy-dispersive X-ray diffraction can be used for simultaneous measurement of several pole figures and that the accuracy is sufficient for the determination of the crystallite orientation distribution. The method is applied to the study of the texture in Cu-43 wt % Zn duplex...... alpha-beta brass rolled to 80% reduction....

  9. Volume and Tissue Composition Changes Measured with Dual-Energy X-Ray Absorptiometry in Melanoma-Related Limb Lymphedema

    DEFF Research Database (Denmark)

    Gjorup, Caroline A; Hendel, Helle W; Zerahn, Bo

    2017-01-01

    Abstracts Background: The aim of this cross-sectional study was to investigate the volume, fat mass, and lean mass in both upper and lower limbs measured with dual-energy X-ray absorptiometry (DXA) in melanoma patients with melanoma-related limb lymphedema. METHODS AND RESULTS: Four hundred thirt...

  10. Influence of Polarization of the Incident Beam on Integrated Intensities in X-Ray Energy-Dispersive Diffractometry

    DEFF Research Database (Denmark)

    Olsen, J. Staun; Buras, B.; Jensen, T.

    1978-01-01

    Polarization measurements of the primary X-ray beam produced by thick copper and tungsten anodes are reported and formulas derived for integrated intensities of Bragg reflections in energy-dispersive diffractometry with the polarization of the primary beam taken into account. It was found...

  11. Levels of 2-dodecylcyclobutanone in ground beef patties irradiated by low-energy X-ray and gamma rays.

    Science.gov (United States)

    Hijaz, Faraj M; Smith, J Scott

    2010-01-01

    Food irradiation improves food safety and maintains food quality by controlling microorganisms and extending shelf life. However, acceptance and commercial adoption of food irradiation is still low. Consumer groups such as Public Citizen and the Food and Water Watch have opposed irradiation because of the formation of 2-alkylcyclobutanones (2-ACBs) in irradiated, lipid-containing foods. The objectives of this study were to measure and to compare the level of 2-dodecylcyclobutanone (2-DCB) in ground beef irradiated by low-energy X-rays and gamma rays. Beef patties were irradiated by low-energy X-rays and gamma rays (Cs-137) at 3 targeted absorbed doses of 1.5, 3.0, and 5.0 kGy. The samples were extracted with n-hexane using a Soxhlet apparatus, and the 2-DCB concentration was determined with gas chromatography-mass spectrometry. The 2-DCB concentration increased linearly (P gamma-ray and low-energy X-ray irradiated patties. There was no significant difference in 2-DCB concentration between gamma-ray and low-energy X-ray irradiated patties (P > 0.05) at all targeted doses. © 2010 Institute of Food Technologists®

  12. A Review of Energy Dispersive X-Ray Fluorescence (EDXRF) as an Analytical Tool in Numismatic Studies.

    Science.gov (United States)

    Navas, María José; Asuero, Agustín García; Jiménez, Ana María

    2016-01-01

    Energy dispersive X-ray fluorescence spectrometry (EDXRF) as an analytical technique in studies of ancient coins is summarized and reviewed. Specific EDXRF applications in historical studies, in studies of the corrosion of coins, and in studies of the optimal working conditions of some laser-based treatment for the cleaning of coins are described. © The Author(s) 2015.

  13. Energy extraction and achievement of the saturation limit in a discharge pumped table-top soft x-ray amplifier.

    Science.gov (United States)

    Rocca, J. J.; Clark, D. P.; Chilla, J. L. A.; Shlyaptsev, V. N.; Marconi, M. C.

    1996-11-01

    There is significant interest in the demonstration of compact soft x-ray amplifiers capable of generating pulses of substantial energy for applications. This motivates the demonstration of gain media generated by compact devices, that can be successfully scaled in length to reach gain saturation. To date, gain saturation had only been achieved in a few soft x-ray laser lines in plasmas generated by some of the world's largest laser facilities.(B. J. MacGowan et al.), Phys. Fluids B 4, 2326 (1992); A. Carillon et al., Phys. Rev. Lett 68, 2917 (1992);B. Rus et al., in AIP Conf. Proc. 332, X-ray lasers 1994, p. 152; S. Wang et al., ibid., p. 293. Previosly we reported large amplification at 46.9 nm in Ne-like argon in a plasma column generated by a fast capillary discharge.(J. J. Rocca et al.), Phys. Rev. Lett. 73, 2192 (1994). Herein we report the generation of laser pulse energies up to 30 μJ at 46.9 nm in such discharge and the first clear evidence of gain saturation of a table-top soft x-ray amplifier. Single pass amplification experiments yielded laser pulse energies up to 6 μJ and double pass amplification using an iridium mirror yielded 30 μJ. The observed saturation of the gain and laser pulse energy are in good agreement with the results of radiation transport calculations. Work supported by the National Science Foundation.

  14. Achievement of the saturation limit and energy extraction in a discharge pumped table-top soft x-ray amplifier

    Science.gov (United States)

    Rocca, J. J.; Clark, D. P.; Chilla, J. L. A.; Shlyaptsev, V. N.

    1996-12-01

    A major goal in ultrashort wavelength laser research is the development of compact "table-top" amplifiers capable of generating soft X-ray pulses of substantial energy that can impact applications. Such development motivates the demonstration of gain media generated by compact devices, that can be successfully scaled in length to reach gain saturation. At this condition, which occurs when the laser intensity reaches the saturation intensity, a large fraction of the energy stored in the laser's upper level can be extracted. To date, gain saturation had only been achieved in a few soft X-ray laser transitions in plasmas generated by some of the world's largest laser facilities.1 Gain in soft X-ray lines has been reported in several compact systems, but in only three cases was the gain length product greater than 5.2-4 In all cases, however, laser energy extraction from table-top amplifiers has been small. A next major step in the development of compact, ultrashort wavelength lasers consists in ad-vancing from gain observations to the demonstration of substantial laser output energies. We have achieved saturated soft X-ray laser operation at 46.9 nm in Ne-like argon in the plasma column generated by a compact capillary discharge.

  15. In situ electrochemical high-energy X-ray diffraction using a capillary working electrode cell geometry.

    Science.gov (United States)

    Young, Matthias J; Bedford, Nicholas M; Jiang, Naisheng; Lin, Deqing; Dai, Liming

    2017-07-01

    The ability to generate new electrochemically active materials for energy generation and storage with improved properties will likely be derived from an understanding of atomic-scale structure/function relationships during electrochemical events. Here, the design and implementation of a new capillary electrochemical cell designed specifically for in situ high-energy X-ray diffraction measurements is described. By increasing the amount of electrochemically active material in the X-ray path while implementing low-Z cell materials with anisotropic scattering profiles, an order of magnitude enhancement in diffracted X-ray signal over traditional cell geometries for multiple electrochemically active materials is demonstrated. This signal improvement is crucial for high-energy X-ray diffraction measurements and subsequent Fourier transformation into atomic pair distribution functions for atomic-scale structural analysis. As an example, clear structural changes in LiCoO2 under reductive and oxidative conditions using the capillary cell are demonstrated, which agree with prior studies. Accurate modeling of the LiCoO2 diffraction data using reverse Monte Carlo simulations further verifies accurate background subtraction and strong signal from the electrochemically active material, enabled by the capillary working electrode geometry.

  16. Prediction and Measurement of X-Ray Spectral and Intensity Distributions from Low Energy Electron Impact Sources

    Science.gov (United States)

    Edwards, David L.

    1999-01-01

    In-vacuum electron beam welding is a technology that NASA considered as a joining technique for manufacture of space structures. The interaction of energetic electrons with metal produces x-rays. The radiation exposure to astronauts performing the in-vacuum electron beam welding must be characterized and minimized to insure safe operating conditions. This investigation characterized the x-ray environment due to operation of an in-vacuum electron beam welding tool. NASA, in a joint venture with the Russian Space Agency, was scheduled to perform a series of welding in space experiments on board the United States Space Shuttle. This series of experiments was named the International Space Welding Experiment (ISWE). The hardware associated with the ISWE was leased to NASA, by the Paton Welding Institute (PWI) in Ukraine, for ground based welding experiments in preparation for flight. Two tests were scheduled, using the ISWE electron beam welding tool, to characterize the radiation exposure to an astronaut during the operation of the ISWE. These radiation exposure tests consisted of Thermoluminescence Dosimeters (TLD's) shielded with material currently used by astronauts during Extra Vehicular Activities (EVA) and exposed to x-ray radiation generated by operation of an in-vacuum electron beam welding tool. This investigation was the first known application of TLD's to measure absorbed dose from x-rays of energy less than 10 KeV. The ISWE hardware was returned to Ukraine before the issue of adequate shielding for the astronauts was verified. Therefore, alternate experimental and analytical methods were developed to measure and predict the x-ray spectral and intensity distribution generated by electron impact with metal. These x-ray spectra were used to calculate the absorbed radiation dose to astronauts. These absorbed dose values were compared to TLD measurements obtained during actual operation of the in-vacuum electron beam welding tool. The calculated absorbed dose

  17. Edge multi-energy soft x-ray diagnostic in Experimental Advanced Superconducting Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Li, Y. L.; Xu, G. S.; Wan, B. N.; Lan, H.; Liu, Y. L.; Wei, J.; Zhang, W.; Hu, G. H.; Wang, H. Q.; Duan, Y. M.; Zhao, J. L.; Wang, L.; Liu, S. C.; Ye, Y.; Li, J.; Lin, X.; Li, X. L. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Tritz, K. [Department of Physics and Astronomy, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Zhu, Y. B. [Department of Physics and Astronomy, University of California, Irvine, California 92697-4575 (United States)

    2015-12-15

    A multi-energy soft x-ray (ME-SXR) diagnostic has been built for electron temperature profile in the edge plasma region in Experimental Advanced Superconducting Tokamak (EAST) after two rounds of campaigns. Originally, five preamplifiers were mounted inside the EAST vacuum vessel chamber attached to five vertically stacked compact diode arrays. A custom mechanical structure was designed to protect the detectors and electronics under constraints of the tangential field of view for plasma edge and the allocation of space. In the next experiment, the mechanical structure was redesigned with a barrel structure to absolutely isolate it from the vacuum vessel. Multiple shielding structures were mounted at the pinhole head to protect the metal foils from lithium coating. The pre-amplifiers were moved to the outside of the vacuum chamber to avoid introducing interference. Twisted copper cooling tube was embedded into the back-shell near the diode to limit the temperature of the preamplifiers and diode arrays during vacuum vessel baking when the temperature reached 150 °C. Electron temperature profiles were reconstructed from ME-SXR measurements using neural networks.

  18. Use of dual-energy x-ray absorptiometry in non-ruminant nutrition research

    Directory of Open Access Journals (Sweden)

    Candido Pomar

    Full Text Available ABSTRACT Precise body composition measurements are essential in animal nutrition studies because the impact of treatments is evaluated based on changes in body weight and composition. Various indirect techniques for animal compositional evaluation have been developed and evaluated for applicability in animal nutrition studies. A fast, accurate, minimally invasive method that requires little input is considered the ideal for providing information about the animal. Measurements obtained by dual-energy x-ray absorptiometry (DXA are highly correlated with those obtained by chemical analysis and dissection. The algorithms of DXA software partition the six chemical components of the body (lipids, water, proteins, carbohydrates, non-bone mineral, and bone mineral into three compartments (total body mineral content, fat mass, and lean mass. Questions have been raised about how this partitioning affects the precision of the DXA method. In addition, the relationship between the DXA measurements and dissected carcass tissues is nonrepresentational of the relationship between DXA and chemical analysis. Furthermore, since DXA devices and their software were developed primarily for human medicine, they may not be fully adequate for animal evaluation. Calibration is required to obtain true values. The DXA method has some advantages and disadvantages that should be identified and controlled before calibration. Nonetheless, DXA is a valuable tool that provides precise, repeatable body composition measurements of live monogastric animals and their carcasses.

  19. An energy dispersive x-ray scattering and molecular dynamics study of liquid dimethyl carbonate.

    Science.gov (United States)

    Gontrani, Lorenzo; Russina, Olga; Marincola, Flaminia Cesare; Caminiti, Ruggero

    2009-12-28

    In this work, we report on the first x-ray diffraction study on liquid dimethyl carbonate. Diffraction spectra were collected with an energy-dispersive instrument, whose wide Q-range allows the structure determination of weakly ordered systems (such as liquids). The structural correlation in this liquid ranges up to about 20 A. The observed patterns are interpreted with a structural model derived from classical molecular dynamics simulations. The simulations were run using OPLS force field, only slightly modified to restrain bond distances to the experimental values. The model structure function and radial distribution functions, averaged among the productive trajectory frames, are in very good agreement with the corresponding experimental ones. Molecular dynamics results show that the deviations from C(2v) cis-cis structure, predicted by ab initio calculations and observed by electron diffraction in the gas phase, are small. By analyzing the intra- and intermolecular pair distribution functions, it was possible to assign the peaks of the experimental radial distribution function to specific structural correlations, and to compute the different average intermolecular coordination numbers. The intermolecular methyl-carbonyl oxygen distance is thoroughly discussed to assess the presence of weak C-H...O hydrogen bonds.

  20. Elemental analysis of mining wastes by energy dispersive X-ray fluorescence (EDXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Fernandez, O. [Laboratory of X-ray Analytical Applications, Institute of Earth Sciences ' Jaume Almera' , CSIC, Sole Sabaris s/n, 08028 Barcelona (Spain)]. E-mail: ogonzalez@ija.csic.es; Queralt, I. [Laboratory of X-ray Analytical Applications, Institute of Earth Sciences ' Jaume Almera' , CSIC, Sole Sabaris s/n, 08028 Barcelona (Spain); Carvalho, M.L. [Centro de Fisica Atomica, Universidade de Lisboa, Av. Prof. Gama Pinto, 21649-003 Lisboa (Portugal); Garcia, G. [Area Edafologia y Quimica Agricola, Departmento de Ciencia y Tecnologia Agraria, Universidad Politecnica de Cartagena, Paseo Alfonso XIII 48, 30203 Cartagena (Spain)

    2007-08-15

    An energy dispersive X-ray fluorescence (EDXRF) tri-axial geometry experimental spectrometer has been employed to determine the concentrations of 13 different elements (K, Ca, Ti, Cr, Mn, Fe, Co, Ni, Cu, Zn, Rb, Sr and Pb) in mine wastes from different depths of two mine tailings from the Cartagena-La Union (Spain) mining district. The elements were determined and quantified using the fundamental parameters method. The concentrations of Cr, Ni, Cu, Zn and Pb were compared to the values from the European and Spanish legislation to evaluate the environmental risk and to classify the wastes as inert wastes or as wastes that have to be control land-filled. The results obtained demonstrate that these wastes can be considered as inert for the considered elements, apart from the concentration levels of Zn and Pb. Whilst Zn slightly overpasses the regulatory levels, Pb mean value exceeds three to six times the value to be considered as Class I potential land-filling material.

  1. Clinical usefulness of calcaneal measurements using dual energy x-ray absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Kohno, Jun [Nagasaki Saiseikai Hospital (Japan); Nakata, Tomoko; Ito, Masako

    1999-07-01

    To investigate the clinical usefulness of calcaneal measurement using dual-energy x-ray absorptiometry (DXA), the ability to detect bone loss and fracture risk were evaluated in comparison with spinal bone mineral density (BMD) measured using DXA and quantitative CT (QCT) and with calcaneal quantitative ultrasound (QUS). Furthermore, to investigate the region in calcaneus in which to detect bone change sensitively, the ability to detect bone loss and fracture risk were also evaluated using new regions of interest (ROIs) that were manually defined. The subjects were 165 healthy women, and 188 female patients with fracture, estrogen deficiency, and steroid-induced osteoporosis. Calcaneal BMD with some manually defined ROIs showed lower precision and less sensitivity in detecting bone loss than BMD measured with automatically defined ROIs. Calcaneal DXA, spinal DXA, and QCT demonstrated significant age-related bone loss, and all measurements could discriminate fracture cases from non-fracture cases. Calcaneal DXA could discriminate the bone loss associated with estrogen deficiency as well as spinal DXA. Furthermore, calcaneal measurements showed a greater ability to detect steroid-induced bone loss than spinal DXA, probably because this group included subjects of advanced age with spondylosis. In conclusion, calcaneal DXA is useful to assess BMD in subjects who are not suitable for spinal measurement, although the ability to detect age-related bone loss in calcaneal DXA is less than in spinal measurements. (author)

  2. Prevalence and type of errors in dual-energy X-ray absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Messina, Carmelo; Bandirali, Michele; D' Alonzo, Nathascja Katia [Universita degli Studi di Milano, Scuola di Specializzazione in Radiodiagnostica, Milano (Italy); Sconfienza, Luca Maria; Sardanelli, Francesco [IRCCS Policlinico San Donato, Unita di Radiologia, San Donato Milanese (Italy); Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, San Donato Milanese (Italy); Di Leo, Giovanni; Papini, Giacomo Davide Edoardo [IRCCS Policlinico San Donato, Unita di Radiologia, San Donato Milanese (Italy); Ulivieri, Fabio Massimo [IRCCS Fondazione Ca' Granda Ospedale Maggiore Policlinico, Mineralometria Ossea Computerizzata e Ambulatorio Malattie Metabolismo Minerale e Osseo, Servizio di Medicina Nucleare, Milano (Italy)

    2015-05-01

    Pitfalls in dual-energy x-ray absorptiometry (DXA) are common. Our aim was to assess rate and type of errors in DXA examinations/reports, evaluating a consecutive series of DXA images of patients examined elsewhere and later presenting to our institution for a follow-up DXA. After ethics committee approval, a radiologist retrospectively reviewed all DXA images provided by patients presenting at our institution for a new DXA. Errors were categorized as patient positioning (PP), data analysis (DA), artefacts and/or demographics. Of 2,476 patients, 1,198 had no previous DXA, while 793 had a previous DXA performed in our institution. The remaining 485 (20 %) patients entered the study (38 men and 447 women; mean age ± standard deviation, 68 ± 9 years). Previous DXA examinations were performed at a total of 37 centres. Of 485 reports, 451 (93 %) had at least one error out of a total of 558 errors distributed as follows: 441 (79 %) were DA, 66 (12 %) PP, 39 (7 %) artefacts and 12 (2 %) demographics. About 20 % of patients did not undergo DXA at the same institution as previously. More than 90 % of DXA presented at least one error, mainly of DA. International Society for Clinical Densitometry guidelines are very poorly adopted. (orig.)

  3. Pediatric dual-energy X-ray absorptiometry: interpretation and clinical and research application

    Directory of Open Access Journals (Sweden)

    Jung Sub Lim

    2010-03-01

    Full Text Available Peak bone mass is established predominately during childhood and adolescence. It is an important determinant of future resistance to osteoporosis and fractures to gain bone mass during growth. The issue of low bone density in children and adolescents has recently attracted much attention and the use of pediatric dual-energy X-ray absorptiometry (DXA is increasing. The process of interpretation of pediatric DXA results is different from that of adults because normal bone mineral density (BMD of children varies by age, body size, pubertal stage, skeletal maturation, sex, and ethnicity. Thus, an appropriate normal BMD Z-score reference value with Z-score should be used to detect and manage low BMD. Z-scores below -2.0 are generally considered a low BMD to pediatrician even though diagnoses of osteoporosis in children and adolescents are usually only made in the presence of at least one fragility fracture. This article will review the basic knowledge and practical guidelines on pediatric DXA based on the International Society for Clinical Densitometry (ISCD Pediatric Official Positions. Also discussed are the characteristics of normal Korean children and adolescents with respect to BMD development. The objective of this review is to help pediatricians to understand when DXA will be useful and how to interpret pediatric DXA reports in the clinical practice for management of children with the potential to develop osteoporosis in adulthood.

  4. Dual energy X-Ray absorptiometry body composition reference values from NHANES.

    Directory of Open Access Journals (Sweden)

    Thomas L Kelly

    Full Text Available In 2008 the National Center for Health Statistics released a dual energy x-ray absorptiometry (DXA whole body dataset from the NHANES population-based sample acquired with modern fan beam scanners in 15 counties across the United States from 1999 through 2004. The NHANES dataset was partitioned by gender and ethnicity and DXA whole body measures of %fat, fat mass/height(2, lean mass/height(2, appendicular lean mass/height(2, %fat trunk/%fat legs ratio, trunk/limb fat mass ratio of fat, bone mineral content (BMC and bone mineral density (BMD were analyzed to provide reference values for subjects 8 to 85 years old. DXA reference values for adults were normalized to age; reference values for children included total and sub-total whole body results and were normalized to age, height, or lean mass. We developed an obesity classification scheme by using estabbody mass index (BMI classification thresholds and prevalences in young adults to generate matching classification thresholds for Fat Mass Index (FMI; fat mass/height(2. These reference values should be helpful in the evaluation of a variety of adult and childhood abnormalities involving fat, lean, and bone, for establishing entry criteria into clinical trials, and for other medical, research, and epidemiological uses.

  5. Obesity increases precision errors in dual-energy X-ray absorptiometry measurements.

    Science.gov (United States)

    Knapp, Karen M; Welsman, Joanne R; Hopkins, Susan J; Fogelman, Ignac; Blake, Glen M

    2012-01-01

    The precision errors of dual-energy X-ray absorptiometry (DXA) measurements are important for monitoring osteoporosis. This study investigated the effect of body mass index (BMI) on precision errors for lumbar spine (LS), femoral neck (NOF), total hip (TH), and total body (TB) bone mineral density using the GE Lunar Prodigy. One hundred two women with BMIs ranging from 18.5 to 45.9 kg/m(2) were recruited. Participants had duplicate DXA scans of the LS, left hip, and TB with repositioning between scans. Participants were divided into 3 groups based on their BMI and the percentage coefficient of variation (%CV) calculated for each group. The %CVs for the normal (obese (>30 kg/m(2)) (n=28) BMI groups, respectively, were LS BMD: 0.99%, 1.30%, and 1.68%; NOF BMD: 1.32%, 1.37%, and 2.00%; TH BMD: 0.85%, 0.88%, and 1.06%; TB BMD: 0.66%, 0.73%, and 0.91%. Statistically significant differences in precision error between the normal and obese groups were found for LS (p=0.0006), NOF (p=0.005), and TB BMD (p=0.025). These results suggest that serial measurements in obese subjects should be treated with caution because the least significant change may be larger than anticipated. Copyright © 2012 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  6. Obesity increases precision errors in total body dual-energy x-ray absorptiometry measurements.

    Science.gov (United States)

    Knapp, Karen M; Welsman, Joanne R; Hopkins, Susan J; Shallcross, Andrew; Fogelman, Ignac; Blake, Glen M

    2015-01-01

    Total body (TB) dual-energy X-ray absorptiometry (DXA) is increasingly being used to measure body composition in research and clinical settings. This study investigated the effect of body mass index (BMI) and body fat on precision errors for total and regional TB DXA measurements of bone mineral density, fat tissue, and lean tissue using the GE Lunar Prodigy (GE Healthcare, Bedford, UK). One hundred forty-four women with BMI's ranging from 18.5 to 45.9 kg/m(2) were recruited. Participants had duplicate DXA scans of the TB with repositioning between examinations. Participants were divided into 3 groups based on their BMI, and the root mean square standard deviation and the percentage coefficient of variation were calculated for each group. The root mean square standard deviation (percentage coefficient of variation) for the normal (obese (>30 kg/m²; n = 32) BMI groups, respectively, were total BMD (g/cm(2)): 0.009 (0.77%), 0.009 (0.69%), 0.011 (0.91%); total fat (g): 545 (2.98%), 486 (1.72%), 677 (1.55%); total lean (g): 551 (1.42%), 540 (1.34%), and 781 (1.68%). These results suggest that serial measurements in obese subjects should be treated with caution because the least significant change may be larger than anticipated. Copyright © 2015 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  7. Evaluation of Lean Body Weight Equation by Dual-Energy X-Ray Absorptiometry Measures.

    Science.gov (United States)

    Beckman, Lauren M; Boullata, Joseph I; Fisher, Paige L; Compher, Charlene W; Earthman, Carrie P

    2017-03-01

    When managing patients with disorders that require clinical intervention, a practical assessment of body habitus is valued. The Duffull-Green lean body weight (LBW) equation was derived and validated in adults across a wide body mass index (BMI) range. Whether this predictive equation will perform well in patients at BMI extremes or perform better than a widely used empiric "ideal" body weight (IBW) equation is unknown. Calculated LBW and calculated IBW were each compared with the dual-energy x-ray absorptiometry (DXA)-derived lean body mass (LBM) by simple linear regression. A mixed model was used to determine how well the LBW equation performed over time in patients with more than 1 DXA measurement. At time 0, 32 patients were 18-67 years old, and all were obese (BMI: 36-65 kg/m2), while the remaining 7 had parenteral nutrition-dependent intestinal failure (BMI: 17-25 kg/m2). A subset of patients underwent bariatric surgery after time 0 (BMI at follow-up: 22-49 kg/m2). The LBW equation was a predictor of LBM ( R2 = 0.67, P weight loss. In the clinical setting, an equation that performs well in various disease states and body sizes is advantageous.

  8. The evaluation of breast tissues removed during reductive mammaplasty with dual energy X-ray absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    De Lorenzo, Antonino [Division of Human Nutrition, University of Tor Vergata in Rome (Italy); Gravante, Gianpiero [Division of Human Nutrition, University of Tor Vergata in Rome (Italy); Department of Surgery, Whipps Cross University Hospital, London (United Kingdom)], E-mail: ggravante@hotmail.com; Sorge, Roberto [Laboratory of Biometry, University of Tor Vergata in Rome (Italy); Nicoli, Fabio; Caruso, Riccardo; Araco, Antonino [Department of Plastic Surgery, University of Tor Vergata in Rome (Italy); Servidio, Michele [Division of Human Nutrition, University of Tor Vergata in Rome (Italy); Orlandi, Augusto [Department of Biopathology, Anatomic Pathology Institute, University of Tor Vergata in Rome (Italy); Cervelli, Valerio [Department of Plastic Surgery, University of Tor Vergata in Rome (Italy)

    2009-06-15

    Purpose: We conducted a case-control study in which patients were evaluated with dual energy X-ray absorptiometry (DEXA) before and after breast reduction surgery, and results were correlated with the histological examination. Our goal was to confirm the DEXA as a precise technique for the measurement of breast composition, in order to propose it for the preoperative evaluation of plastic surgery patients. Materials and methods: We prospectively recruited all women that underwent reduction mammaplasty and excluded patients with contraindications to the operation or those that previously underwent bariatric surgery to reduce their weight. Patients were evaluated with DEXA 1 week before and after surgery. Results: From February to October 2006 we recruited 25 patients. The statistical analysis found a significant reduction of weight, BMI, regional fat free mass and fat mass after the operation. The comparison between DEXA and the histological analysis produced a correlation r = 0.989 (r{sup 2} = 0.978), with a predictivity of 98% and a percentage of error 8.3% (95% confidence intervals -252.6, 273.7; 95% limits of agreements of Bland and Altman -436.0, 457.1). Similar results were obtained with the analysis of fat. Conclusions: Our study demonstrated that conventional segmental DEXA is a very precise technique to measure the amount of tissue removed in breast reductions and could open future application in the preoperative assessment of patients undergoing such operations.

  9. Evaluation of Dual Energy X Ray Absorbsiometry and Osteoporosis Risk Factors in 197 Patients - Original Investigation

    Directory of Open Access Journals (Sweden)

    Şirin Raife Çoban

    2007-12-01

    Full Text Available Aim: To examine the risk factors for osteoporosis, dual energy X ray absorbsiometry (DXA measures, dorsolomber radiographics and laboratory analysis of 197 patients which followed in Goztepe Education and Research Hospital Physical Medicine and Rehabilitation Policlinics. Patients and Methods: 197 patients, ages between 37-78, which followed in Physical Medicine and Rehabilitation Policlinics, cross-sectionally evaluated. Patients interrogated about risk factors like life style, calcium-caffeine-alcohol consumption in nutrition, cigarette smoking, age ot menarch, number of births, time of menopause, physical activity levels and their dorsolomber AP-lateral radiograpichs, laboratory analysis and bone mineral density measures with DXA has done. Osteoporosis-osteopenia classification has done by the T score criterias of World Health Organisation. Pearson correlation analysis and ANOVA has used as statistical method. Results: Mean age was 59,24±8,33. Mean body mass index was 26,42±3,99. A significant correlation did not found between life style, nutrition, age of menarch, number of births, early fracture, compression fracture, sunbathe and T scores. A statistically significant correlation has found between age and femur neck T scores; body mass index and lomber-femoral T scores; time of menopause and femur neck T scores (p<0,005. Conclussion: A significant correlation did not found between the minimal risk factors and DXA measures. Age, body mass index and time of menopause has found related to bone mineral density measures. (From the World of Osteoporosis 2007;13:80-2

  10. The effect of adiposity measured by dual-energy X-ray absorptiometry on lung function.

    Science.gov (United States)

    Sutherland, T J T; Goulding, A; Grant, A M; Cowan, J O; Williamson, A; Williams, S M; Skinner, M A; Taylor, D R

    2008-07-01

    Respiratory function is impaired in obesity but there are limitations with body mass index and skin-fold thickness in assessing this effect. The present authors hypothesised that the regional distribution of body fat and lean mass, as measured by dual-energy X-ray absorptiometry (DXA), might be more informative than conventional measurements of total body fat. In total, 107 subjects (55 female, 51.4%) aged 20-50 yrs with no respiratory disease were recruited. Respiratory function tests, anthropometric measurements and a DXA scan were performed. Partial correlation and linear regression analyses were used to explore the effect of adiposity and lean body mass on respiratory function. The majority of respiratory function parameters were significantly correlated with DXA and non-DXA measurements of body fat. Neither thoracic nor abdominal fat had a greater effect. There were some differences in the effect of adiposity between the sexes. Respiratory function was negatively associated with lean body mass in females but positively associated in males. This disappeared after adjustment in females but remained in males. The effects of thoracic and abdominal body fat on respiratory function are comparable but cannot be separated from one another.

  11. On the variation of solar flare coronal X-ray source sizes with energy

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey, Natasha L. S.; Kontar, Eduard P.; Bian, Nicolas H. [School of Physics and Astronomy, University of Glasgow, G12 8QQ Glasgow (United Kingdom); Emslie, A. Gordon, E-mail: n.jeffrey@physics.gla.ac.uk [Department of Physics and Astronomy, Western Kentucky University, Bowling Green, KY 42101 (United States)

    2014-05-20

    Observations with RHESSI have enabled the detailed study of the structure of dense hard X-ray coronal sources in solar flares. The variation of source extent with electron energy has been discussed in the context of streaming of non-thermal particles in a one-dimensional cold target model and the results used to constrain both the physical extent of, and density within, the electron acceleration region. Here, we extend this investigation to a more physically realistic model of electron transport that takes into account the finite temperature of the ambient plasma, the initial pitch angle distribution of the accelerated electrons, and the effects of collisional pitch angle scattering. The finite temperature results in the thermal diffusion of electrons, which leads to the observationally inferred value of the acceleration region volume being an overestimate of its true value. The different directions of the electron trajectories, a consequence of both the non-zero injection pitch angle and scattering within the target, cause the projected propagation distance parallel to the guiding magnetic field to be reduced, so that a one-dimensional interpretation can overestimate the actual density by a factor of up to ∼6. The implications of these results for the determination of acceleration region properties (specific acceleration rate, filling factor, etc.) are discussed.

  12. Constraining Dark Energy with X-ray Galaxy Clusters, Supernovae and the Cosmic Microwave Background

    Energy Technology Data Exchange (ETDEWEB)

    Rapetti, D

    2005-04-18

    We present new constraints on the evolution of dark energy from an analysis of Cosmic Microwave Background, supernova and X-ray galaxy cluster data. Our analysis employs a minimum of priors and exploits the complementary nature of these data sets. We examine a series of dark energy models with up to three free parameters: the current dark energy equation of state w{sub 0}, the early time equation of state w{sub et} and the scale factor at transition, a{sub t}. From a combined analysis of all three data sets, assuming a constant equation of state and that the Universe is flat, we measure w{sub 0} = 1.05{sub -0.12}{sup +0.10}. Including w{sub et} as a free parameter and allowing the transition scale factor to vary over the range 0.5 < a{sub t} < 0.95 where the data sets have discriminating power, we measure w{sub 0} = -1.27{sub -0.39}{sup +0.33} and w{sub et} = -0.66{sub -0.62}{sup +0.44}. We find no significant evidence for evolution in the dark energy equation of state parameter with redshift. Marginal hints of evolution in the supernovae data become less significant when the cluster constraints are also included in the analysis. The complementary nature of the data sets leads to a tight constraint on the mean matter density, {Omega}{sub m} and alleviates a number of other parameter degeneracies, including that between the scalar spectral index n{sub s}, the physical baryon density {Omega}{sub b}h{sup 2} and the optical depth {tau}. This complementary nature also allows us to examine models in which we drop the prior on the curvature. For non-flat models with a constant equation of state, we measure w{sub 0} = -1.09{sub -0.15}{sup +0.12} and obtain a tight constraint on the current dark energy density, {Omega}{sub de} = 0.70 {+-} 0.03. For dark energy models other than a cosmological constant, energy-momentum conservation requires the inclusion of spatial perturbations in the dark energy component. Our analysis includes such perturbations, assuming a sound speed c

  13. A track length estimator method for dose calculations in low-energy X-ray irradiations. Implementation, properties and performance

    Energy Technology Data Exchange (ETDEWEB)

    Baldacci, F.; Delaire, F.; Letang, J.M.; Sarrut, D.; Smekens, F.; Freud, N. [Lyon-1 Univ. - CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Centre Leon Berard (France); Mittone, A.; Coan, P. [LMU Munich (Germany). Dept. of Physics; LMU Munich (Germany). Faculty of Medicine; Bravin, A.; Ferrero, C. [European Synchrotron Radiation Facility, Grenoble (France); Gasilov, S. [LMU Munich (Germany). Dept. of Physics

    2015-05-01

    The track length estimator (TLE) method, an 'on-the-fly' fluence tally in Monte Carlo (MC) simulations, recently implemented in GATE 6.2, is known as a powerful tool to accelerate dose calculations in the domain of low-energy X-ray irradiations using the kerma approximation. Overall efficiency gains of the TLE with respect to analogous MC were reported in the literature for regions of interest in various applications (photon beam radiation therapy, X-ray imaging). The behaviour of the TLE method in terms of statistical properties, dose deposition patterns, and computational efficiency compared to analogous MC simulations was investigated. The statistical properties of the dose deposition were first assessed. Derivations of the variance reduction factor of TLE versus analogous MC were carried out, starting from the expression of the dose estimate variance in the TLE and analogous MC schemes. Two test cases were chosen to benchmark the TLE performance in comparison with analogous MC: (i) a small animal irradiation under stereotactic synchrotron radiation therapy conditions and (ii) the irradiation of a human pelvis during a cone beam computed tomography acquisition. Dose distribution patterns and efficiency gain maps were analysed. The efficiency gain exhibits strong variations within a given irradiation case, depending on the geometrical (voxel size, ballistics) and physical (material and beam properties) parameters on the voxel scale. Typical values lie between 10 and 103, with lower levels in dense regions (bone) outside the irradiated channels (scattered dose only), and higher levels in soft tissues directly exposed to the beams.

  14. THE CHANDRA MULTI-WAVELENGTH PROJECT: OPTICAL SPECTROSCOPY AND THE BROADBAND SPECTRAL ENERGY DISTRIBUTIONS OF X-RAY-SELECTED AGNs

    Energy Technology Data Exchange (ETDEWEB)

    Trichas, Markos; Green, Paul J.; Aldcroft, Tom; Kim, Dong-Woo; Mossman, Amy [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138 (United States); Silverman, John D. [Institute for the Physics and Mathematics of the Universe (IPMU), University of Tokyo, Kashiwanoha 5-1-5, Kashiwa-shi, Chiba 277-8568 (Japan); Barkhouse, Wayne [Department of Physics and Astrophysics, University of North Dakota, Grand Forks, ND 58202 (United States); Cameron, Robert A. [W. W. Hansen Experimental Physics Laboratory, Kavli Institute for Particle Astrophysics and Cosmology, Department of Physics and SLAC National Accelerator Laboratory, Stanford University, Stanford, CA 94305 (United States); Constantin, Anca [Department of Physics and Astronomy, James Madison University, PHCH, Harrisonburg, VA 22807 (United States); Ellison, Sara L. [Department of Physics and Astronomy, University of Victoria, Victoria, BC V8P 1A1 (Canada); Foltz, Craig [Division of Astronomical Sciences, National Science Foundation, 4201 Wilson Blvd., Arlington, VA 22230 (United States); Haggard, Daryl [Center for Interdisciplinary Exploration and Research in Astrophysics, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208 (United States); Jannuzi, Buell T. [NOAO, Kitt Peak National Observatory, Tucson, AZ 85726 (United States); Marshall, Herman L. [Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA 02139 (United States); Perez, Laura M. [Department of Astronomy, California Institute of Technology, 1200 East California Blvd, Pasadena, CA 91125 (United States); Romero-Colmenero, Encarni [South African Astronomical Observatory, P.O. Box 9, Observatory, 7935 (South Africa); Ruiz, Angel [Osservatorio Astronomico di Brera-INAF, Milan (Italy); Smith, Malcolm G., E-mail: mtrichas@cfa.harvard.edu [Cerro Tololo Interamerican Observatory, La Serena (Chile); and others

    2012-06-01

    From optical spectroscopy of X-ray sources observed as part of the Chandra Multi-wavelength Project (ChaMP), we present redshifts and classifications for a total of 1569 Chandra sources from our targeted spectroscopic follow-up using the FLWO/1.5 m, SAAO/1.9 m, WIYN 3.5 m, CTIO/4 m, KPNO/4 m, Magellan/6.5 m, MMT/6.5 m, and Gemini/8 m telescopes, and from archival Sloan Digital Sky Survey (SDSS) spectroscopy. We classify the optical counterparts as 50% broad-line active galactic nuclei (AGNs), 16% emission line galaxies, 14% absorption line galaxies, and 20% stars. We detect QSOs out to z {approx} 5.5 and galaxies out to z {approx} 3. We have compiled extensive photometry, including X-ray (ChaMP), ultraviolet (GALEX), optical (SDSS and ChaMP-NOAO/MOSAIC follow-up), near-infrared (UKIDSS, Two Micron All Sky Survey, and ChaMP-CTIO/ISPI follow-up), mid-infrared (WISE), and radio (FIRST and NVSS) bands. Together with our spectroscopic information, this enables us to derive detailed spectral energy distributions (SEDs) for our extragalactic sources. We fit a variety of template SEDs to determine bolometric luminosities, and to constrain AGNs and starburst components where both are present. While {approx}58% of X-ray Seyferts (10{sup 42} erg s{sup -1} < L{sub 2-10keV} <10{sup 44} erg s{sup -1}) require a starburst event (>5% starburst contribution to bolometric luminosity) to fit observed photometry only 26% of the X-ray QSO (L{sub 2-10keV} >10{sup 44} erg s{sup -1}) population appear to have some kind of star formation contribution. This is significantly lower than for the Seyferts, especially if we take into account torus contamination at z > 1 where the majority of our X-ray QSOs lie. In addition, we observe a rapid drop of the percentage of starburst contribution as X-ray luminosity increases. This is consistent with the quenching of star formation by powerful QSOs, as predicted by the merger model, or with a time lag between the peak of star formation and QSO

  15. Fourier Analysis of Single-Shot Dual-Energy X-ray Imaging Characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jun Woo; Kim, Dong Woon; Kim, Ho Kyung [Pusan National University, Busan (Korea, Republic of)

    2016-05-15

    The sandwich detector was realized by stacking two scintillator-based flat-panel detectors (FPDs) between which an intermediate copper (Cu) filter layer was placed to further enhance spectral energy separation. As a result, the proper selection of filter material and its thickness could be a trade-off between the extent of energy separation (hence, DE image quality) and image noise due to reduction in the number of x-ray quanta reaching the rear FPD. Although the conventional kVp-switching dual-shot method showed better image qualities than the single-shot method because of larger spectral energy separation, the motion-artifact-free DE image with reasonably good image quality was a potential prospect of the single-shot method. For the reliable and better use of the sandwich detector for specific imaging applications, the sandwich detector should be optimally designed with a proper selection of scintillator material and thickness in each detector layer (i.e. the front and rear detectors), and aforementioned intermediate filter material and thickness. It is noted that glue is used to adhere the fragile photodiode array onto the ceramic substrate and these glue patterns are apparent in the rear and DE images. The glue pattern in the rear image comes from the front FPD. Unlike the conventional ESF as shown in Fig. 3(a), the ESF obtained from the subtracted image showed an enhancement as shown in Fig. 3(b). Consequently, the MTF obtained from the subtraction ESF showed a bandpass filter characteristic, as shown in Fig. 3(c), unlike the conventional low-pass filter characteristic (i.e., monotonic decrease of MTF value with increasing the spatial frequency). This MTF characteristic is due to the subtraction of two images with different spatial resolving powers (i.e., different thicknesses of phosphors between the front and rear detectors) as can be seen in unsharp masking digital image processing, which subtracts Gaussian-blurred image from the original image.

  16. Investigation of multilayer X-ray optics for the 6 keV to 20 keV energy range.

    Science.gov (United States)

    Oberta, P; Platonov, Y; Flechsig, U

    2012-09-01

    The X-ray optics group at the Swiss Light Source in co-operation with RIT (Rigaku Innovative Technologies) have investigated seven different multilayer samples. The goal was to find an ideal multilayer structure for the energy range between 6 keV and 20 keV in terms of energy resolution and reflectivity. Such multilayer structures deposited on substrates can be used as X-ray monochromators or reflecting synchrotron mirrors. The measured reflectivities agree with the simulated ones. They cover a reflectivity range from 45% to 80% for energies between 6 keV and 10 keV, and 80% to 90% for energies between 10 keV and 20 keV. The experimentally measured energy resolution of the samples lies between 0.3% and 3.5%.

  17. Energy dependence of normal branch quasi-periodic intensity oscillations in low-mass X-ray binaries

    Science.gov (United States)

    Miller, Guy S.; Lamb, Frederick K.

    1992-01-01

    The properties of the approximately 6 Hz quasi-periodic X-ray intensity oscillations observed in the low-mass X-ray binary Cyg X-2 when it is on the normal spectral branch are shown to be consistent with a model in which photons from a central source with a fixed spectrum are Comptonized by an oscillating radial inflow. As the electron scattering optical depth of the flow varies, the spectrum of the escaping X-rays appears to rotate about a pivot energy that depends mainly on the electron temperature in the flow. The temperature derived from the observed energy dependence of the Cyg X-2 normal branch oscillations is approximately 1 keV, in good agreement with the estimated Compton temperature of its X-ray spectrum. The mean optical depth tau of the Comptonizing flow is inferred to be about 10, while the change in tau over an oscillation is estimated to be about 1; both values are in good agreement with radiation hydrodcode simulations of the radial flow.

  18. NuSTAR detection of high-energy X-ray emission and rapid variability from sagittarius A* flares

    DEFF Research Database (Denmark)

    Barrière, Nicolas M.; Tomsick, John A.; Baganoff, Frederick K.

    2014-01-01

    Sagittarius A* harbors the supermassive black hole that lies at the dynamical center of our Galaxy. Sagittarius A* spends most of its time in a low luminosity emission state but flares frequently in the infrared and X-ray, increasing up to a few hundred fold in brightness for up to a few hours...... at a time. The physical processes giving rise to the X-ray flares are uncertain. Here we report the detection with the NuSTAR observatory in Summer and Fall 2012 of four low to medium amplitude X-ray flares to energies up to 79 keV. For the first time, we clearly see that the power-law spectrum...... of Sagittarius A* X-ray flares extends to high energy, with no evidence for a cutoff. Although the photon index of the absorbed power-law fits are in agreement with past observations, we find a difference between the photon index of two of the flares (significant at the 95% confidence level). The spectra...

  19. Extrapolation Ionization Chamber Dosimetry of Fluorescent X-Ray Energies from 4.5 to 19.6 keV.

    Science.gov (United States)

    Rakowski, Joseph T; Tucker, Mark A; Snyder, Michael G; Makar, Simon P; Yudele, Mark; Burmeister, Jay; Joiner, Michael C

    2016-09-01

    Characteristic X rays of energies less than approximately 20 keV are of interest in radiobiology and radiation oncology. There is evidence that these low-energy photons produce higher relative biological effectiveness (RBE) and lower oxygen enhancement ratio (OER) relative to higher energies. Lower energy X rays also offer the advantage of healthy tissue sparing beyond the target treatment depth. Electronic brachytherapy systems that can deliver characteristic and bremsstrahlung X rays of varying energy are in clinical use as well as under development. We performed low-energy extrapolation ionization chamber dosimetry using two methods: 1. the exposure-to-dose method; and 2. the Burlin theory method combined with the extrapolation chamber method of Klevenhagen. We investigated fluorescent X rays emitted from seven metals: titanium (Ti, Z = 22); chromium (Cr, Z = 24); iron (Fe, Z = 26); cobalt (Co, Z = 27); copper (Cu, Z = 29); zinc (Zn, Z = 30); and molybdenum (Mo, Z = 42). X rays were produced by irradiation of the metals with a 55 kVp, 45 mA silver anode spectrum. The data obtained were air kerma rate (cGy/min), and radiation dose rate (cGy/min) in phosphate-buffered saline (PBS) solution and water. Air kerma rates ranged from 3.55 ± 0.10 to 14.36 ± 0.39 cGy/min. Dose rates ranged from 3.85 ± 0.10 to 16.96 ± 0.46 cGy/min in PBS and 3.59 ± 0.10 to 16.06 ± 0.43 cGy/min in water. Dose-rate energy dependence of both models was examined by taking a ratio of measured to Monte Carlo calculated dose rates. Dosimetry method 1 exhibited a linear relationship across all energies with a slope of 0.0127 keV(-1) and R(2) of 0.9276. Method 2 exhibited a linear relationship across all energies with a slope of 0.0467 keV(-1) and R(2) of 0.9933. Method 1 or 2 may be used as a relative dosimetry system to derive dose rates to water by using a second reference ion chamber with a NIST-traceable calibration for the molybdenum spectrum.

  20. Hard X-Ray Flare Source Sizes Measured with the Ramaty High Energy Solar Spectroscopic Imager

    Science.gov (United States)

    Dennis, Brian R.; Pernak, Rick L.

    2009-01-01

    Ramaty High Energy Solar Spectroscopic Imager (RHESSI) observations of 18 double hard X-ray sources seen at energies above 25 keV are analyzed to determine the spatial extent of the most compact structures evident in each case. The following four image reconstruction algorithms were used: Clean, Pixon, and two routines using visibilities maximum entropy and forward fit (VFF). All have been adapted for this study to optimize their ability to provide reliable estimates of the sizes of the more compact sources. The source fluxes, sizes, and morphologies obtained with each method are cross-correlated and the similarities and disagreements are discussed. The full width at half-maximum (FWHM) of the major axes of the sources with assumed elliptical Gaussian shapes are generally well correlated between the four image reconstruction routines and vary between the RHESSI resolution limit of approximately 2" up to approximately 20" with most below 10". The FWHM of the minor axes are generally at or just above the RHESSI limit and hence should be considered as unresolved in most cases. The orientation angles of the elliptical sources are also well correlated. These results suggest that the elongated sources are generally aligned along a flare ribbon with the minor axis perpendicular to the ribbon. This is verified for the one flare in our list with coincident Transition Region and Coronal Explorer (TRACE) images. There is evidence for significant extra flux in many of the flares in addition to the two identified compact sources, thus rendering the VFF assumption of just two Gaussians inadequate. A more realistic approximation in many cases would be of two line sources with unresolved widths. Recommendations are given for optimizing the RHESSI imaging reconstruction process to ensure that the finest possible details of the source morphology become evident and that reliable estimates can be made of the source dimensions.

  1. Accurate efficiency calibration of a low-energy HPGe detector using a monochromatic x-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Plagnard, Johann; Bobin, Christophe; Lepy, Marie-Christine [Commissariat a l' Energie Atomique, Laboratoire National Henri Becquerel, 91191 Gif-sur-Yvette Cedex (France)

    2007-05-15

    HPGe detector efficiency has been calibrated using complementary methods involving radioactive x-ray standards, reference synchrotron flux (Super ACO, LURE, France) and a monochromatic x-ray source (SOLEX), combined with Monte Carlo simulation. In the study described here, SOLEX was used to determine the thickness of detector components that create absorption sites in front of the active zone of the detector, by energy scanning in the vicinity of their K and L binding energies. The layers of aluminium (infrared shielding), nickel (electrical contact) and germanium (dead layer) have been measured. This approach ensures accurate determination of the thickness of each component and enables the detector efficiency calculation by Monte Carlo simulation. Differences between simulated data and experimental efficiency values are about 1-5% at energies above 1400 eV and reach 20% at lower energies. (authors)

  2. Polycrystalline CdZnTe thick films for low energy x-ray: system evaluation.

    Science.gov (United States)

    Yuk, Sunwoo; Park, Shin-Woong; Yi, Yun

    2006-01-01

    The X-ray response of polycrystalline-CdZnTe was measured by signal-to-noise (S/N) analysis. The CdZnTe material has optimal properties in a solid-state X-ray detector, and much research has focused on single crystal CdZnTe with a small-sized, silicon readout device. However, it would be difficult to apply CdTe or CdZnTe single crystal to large area, flat panel detectors, such as those used for radiography and mammography. As an alternative of single crystal CdZnTe, we have grown thick, polycrystalline CdZnTe films of high resistivity (>5 x 10(9) Ohm cm) using the thermal evaporation method on carbon substrate. A high signal-to-noise value has a direct impact on the performance of CdZnTe X-ray detectors. Important image parameters, such as dynamic range and detective quantum efficiency, rely on the signal and noise characteristics of the system. In this paper, we analyzed the properties of the X-ray detector and obtained images of the X-ray detector using the data acquisition system. The X-ray detector used the Cd1-xZnxTe (x=0.04), which used carbon substrate and gold as the electrode. The detector design is planar and 32 mm x 10 mm in size, and it has a 1.75mm x 1mm pixel electrode size and a detector thickness of 150 microm.

  3. Crystal engineering on industrial diaryl pigments using lattice energy minimizations and X-ray powder diffraction.

    Science.gov (United States)

    Schmidt, Martin U; Dinnebier, Robert E; Kalkhof, Holger

    2007-08-23

    Diaryl azo pigments play an important role as yellow pigments for printing inks, with an annual pigment production of more than 50,000 t. The crystal structures of Pigment Yellow 12 (PY12), Pigment Yellow 13 (PY13), Pigment Yellow 14 (PY14), and Pigment Yellow 83 (PY83) were determined from X-ray powder data using lattice energy minimizations and subsequent Rietveld refinements. Details of the lattice energy minimization procedure and of the development of a torsion potential for the biphenyl fragment are given. The Rietveld refinements were carried out using rigid bodies, or constraints. It was also possible to refine all atomic positions individually without any constraint or restraint, even for PY12 having 44 independent non-hydrogen atoms per asymmetric unit. For PY14 (23 independent non-hydrogen atoms), additionally all atomic isotropic temperature factors could be refined individually. PY12 crystallized in a herringbone arrangement with twisted biaryl fragments. PY13 and PY14 formed a layer structure of planar molecules. PY83 showed a herringbone structure with planar molecules. According to quantum mechanical calculations, the twisting of the biaryl fragment results in a lower color strength of the pigments, whereas changes in the substitution pattern have almost no influence on the color strength of a single molecule. Hence, the experimentally observed lower color strength of PY12 in comparison with that of PY13 and PY83 can be explained as a pure packing effect. Further lattice energy calculations explained that the four investigated pigments crystallize in three different structures because these structures are the energetically most favorable ones for each compound. For example, for PY13, PY14, or PY83, a PY12-analogous crystal structure would lead to considerably poorer lattice energies and lower densities. In contrast, lattice energy calculations revealed that PY12 could adopt a PY13-type structure with only slightly poorer energy. This structure was

  4. A Variable-Energy Soft X-Ray Microprobe to Investigate Mechanisms of the Radiation-Induced Bystander Effect.

    Energy Technology Data Exchange (ETDEWEB)

    Folkard, Melvyn; Vojnovic, Borivoj; Schettino, Giuseppe; Atkinson, Kirk; Prise, Kevin, M.; Michael, Barry, D.

    2007-01-23

    The Gray Cancer Institute has pioneered the use of X ray focussing techniques to develop systems for micro irradiating individual cells and sub cellular targets in vitro. Cellular micro irradiation is now recognised as a highly versatile technique for understanding how ionising radiation interacts with living cells and tissues. The strength of the technique lies in its ability to deliver precise doses of radiation to selected individual cells (or sub cellular targets). The application of this technique in the field of radiation biology continues to be of great interest for investigating a number of phenomena currently of concern to the radiobiological community. One important phenomenon is the so called ‘bystander effect’ where it is observed that unirradiated cells can also respond to signals transmitted by irradiated neighbours. Clearly, the ability of a microbeam to irradiate just a single cell or selected cells within a population is well suited to studying this effect. Our prototype ‘tabletop’ X-ray microprobe was optimised for focusing 278 eV C-K X rays and has been used successfully for a number of years. However, we have sought to develop a new variable energy soft X-ray microprobe capable of delivering focused CK (0.28 keV), Al-K (1.48 keV) and notably, Ti-K (4.5 keV) X rays. Ti-K X rays are capable of penetrating several cell layers and are therefore much better suited to studies involving tissues and multi cellular layers. In our new design, X-rays are generated by the focussed electron bombardment of a material whose characteristic-K radiation is required. The source is mounted on a 1.5 x 1.0 metre optical table. Electrons are generated by a custom built gun, designed to operate up to 15 kV. The electrons are focused using a permanent neodymium iron boron magnet assembly. Focusing is achieved by adjusting the accelerating voltage and by fine tuning the target position via a vacuum position feedthrough. To analyze the electron beam properties, a

  5. Repetitive flash x-ray generator as an energy transfer source utilizing a compact-glass body diode

    Science.gov (United States)

    Shikoda, Arimitsu; Sato, Eiichi; Kimura, Shingo; Isobe, Hiroshi; Takahashi, Kei; Tamakawa, Yoshiharu; Yanagisawa, Toru

    1991-04-01

    The studies of a repetitive flash x-ray generator as an energy source achieved with a compact diode with a permeable anode are described. This source consisted of the following essential components: a constant negative high-voltage power supply of up to -100kV, a modified two-stage Marx pulser, a repetitive trigger device, and an x-ray tube. Two condensers in the pulser were charged from -50 to -80kV, and the output voltages (no-load) were less than -130kV. Since the capacity of each condenser was 85OpF, the total capacity during discharge was 425pF. The maximum tube voltage and the tube current were about 85kV and 0. 3kA, respectively. The xray pulse widths were less than l2Ons, and the repetitive rate was less than 40Hz. The time-integrated x-ray intensity was about 25pC/kg at 24mm per pulse with a charged voltage of 60kV and an anode-cathode (A-C) space of 9. 0mm, and the maximum size of the x-ray source was equivalent to an anode diameter of 27mm.

  6. Design and Performance of a TES X-ray Microcalorimeter Array for Energy Dispersive Spectroscopy on Scanning Transmission Electron Microscope

    Science.gov (United States)

    Muramatsu, Haruka; Nagayoshi, K.; Hayashi, T.; Sakai, K.; Yamamoto, R.; Mitsuda, K.; Yamasaki, N. Y.; Maehata, K.; Hara, T.

    2016-07-01

    We discuss the design and performance of a transition edge sensor (TES) X-ray microcalorimeter array for scanning transmission electron microscope (STEM)-energy dispersive X-ray spectroscopy (EDS). The TES X-ray microcalorimeter has better energy resolution compared to conventional silicon drift detector and STEM-EDS utilizing a TES detector makes it possible to map the distribution of elements on a specimen in addition to analyze the composition. The requirement for a TES detector is a high counting rate (>20 kcps), wide energy band (0.5-15 keV) and good energy resolution (<10 eV) full width at half maximum. The major improvement of this development is to increase the maximum counting rate. In order to accommodate the high counting rate, we adopted an 8 × 8 format, 64-pixel array and common biasing scheme for the readout method. We did all design and fabrication of the device in house. With the device we have fabricated most recently, the pulse decay time is 40 \\upmu s which is expected to achieve 50 kcps. For a single pixel, the measured energy resolution was 7.8 eV at 5.9 keV. This device satisfies the requirements of counting rate and energy resolution, although several issues remain where the performance must be confirmed.

  7. Errors in dual energy x-ray absorptiometry estimation of body composition induced by hypohydration.

    Science.gov (United States)

    Rodriguez-Sanchez, Nidia; Galloway, Stuart D R

    2015-02-01

    Dual energy x-ray absorptiometry (DXA) is a popular tool to determine body composition (BC) in athletes, and is used for analysis of fat-free soft tissue mass (FFST) or fat mass (FM) gain/loss in response to exercise or nutritional interventions. The aim of the current study was to assess the effect of exercise-heat stress induced hypohydration (HYP, >2% of body mass (BM) loss) vs. maintenance of euhydration (EUH) on DXA estimates of BC, sum of skinfolds (SF), and impedance (IMP) measurements in athletes. Competitive athletes (23 males and 15 females) recorded morning nude BM for 7 days before the first main trial. Measurements on the first trial day were conducted in a EUH condition, and again after exercise-heat stress induced HYP. On the second trial day, fluid and electrolyte losses were replaced during exercise using a sports drink. A reduction in total BM (1.6 ± 0.4 kg; 2.3 ± 0.4% HYP) and total FFST (1.3 ± 0.4 kg), mainly from trunk (1.1 ± 0.5 kg), was observed using DXA when participants were HYP, reflecting the sweat loss. Estimated fat percent increased (0.3 ± 0.3%), however, total FM did not change (0.1 ± 0.2 kg). SF and IMP declined with HYP (losses of 1.5 ± 2.9% and 1.6 ± 3% respectively) suggesting FM loss. When EUH was maintained there were no significant changes in BM, DXA estimates, or SF values pre to post exercise, but IMP still declined. We conclude that use of DXA for FFST assessment in athletes must ensure a EUH state, particularly when considering changes associated with nutritional or exercise interventions.

  8. Elemental contents in exotic Brazilian tropical fruits evaluated by energy dispersive X-ray fluorescence

    Directory of Open Access Journals (Sweden)

    Oliveira Alessandra Lopes de

    2006-01-01

    Full Text Available The exotic flavor of Brazilian tropical fruits led to increased consumption. Consumers awareness regarding balanced diets, makes necessary determining nutritional composition - vitamins and minerals of the fruits ordinarily consumed. This study contributed to the evaluation of macro (K, Ca and microelements (Mn, Fe, Cu, Zn and Br in eight exotic Brazilian tropical fruits: "abiu" (Lucuma caimito Ruiz & Pav., "jenipapo" (Genipa americana L., "jambo rosa" (rose apple, Eugenia Jambos L., "jambo vermelho" (Syzygium malaccence L., Merr & Perry, "macaúba" (Acrocomia aculeata Jacq. Lood. Ex Mart., "mangaba" (Hancornia speciosa, "pitanga" (Brazilian Cherry, Eugenia uniflora L., and tamarind (Tamarindus indica L., using the Energy Dispersive X-Ray Fluorescence (EDXRF technique. "jambo vermelho" and "macaúba" presented the highest values of K concentrations, 1,558 and 1,725 mg 100 g-1, respectively. On the other hand, Ca concentrations were highest in "macaúba" (680 mg 100 g-1 and "jenipapo" (341 mg 100 g-1. The microelemental concentrations in these eight fruits ranged from: 0.9 to 2.0 mg 100 g-1 for Mn, 3.9 to 11.4 mg 100 g-1 for Fe, 0.5 to 1.0 mg 100 g-1 for Cu, 0.6 to 1.5 mg 100 g-1 for, Zn and 0.3 to 1.3 mg 100 g-1 for Br. The amounts of macro and microelements in the eight fruits analyzed were compared to other tropical fruits and it was found that some of them could be classified as rich sources for these macro and microelements.

  9. Hip Strentgh Analysis By Dual Energy X-Ray Absorbtiometry in Nephrolithiasis Patients

    Directory of Open Access Journals (Sweden)

    Aynur Ozen

    2014-12-01

    Full Text Available Aim: The aim of this study was to assess the hip geometric parameters measured by dual-energy X-ray absorptiometry in patients with kidney stones and to compare normal population. Material and Method: This study is retrospectively evaluation and performed hip structural analysis of another prospective study data, included 72 patients with kidney stones (29 female, 43 male and 94 control subjects (31 women, 63 men. Bone mineral density and structural parameters such as hip axis length, cross-sectional area, cross-sectional moment of inertia, femur strength index and section modulus of femur neck have been measured in each groups. Results: The patients and control subjects were anthropometrically identical (P>0.05. There were no statistical difference for hip axis length, cross-sectional area, cross-sectional moment of inertia and section modulus between of groups when take into consideration of gender effect (P>0.05. The presence of nephrolithiasis was determined that there was not predictive effects on femur neck bone mineral density, hip axis length, cross-sectional moment of inertia, section modulus, femur strength index and cross-sectional area. To be female gender was a negatif effect on bone mineral density, hip axis length, cross-sectional moment of inertia and section modulus. Discussion: As a conclusion, we did not found any differences on bone mineral density and hip structural parameters measured with hip strength analysis program between nephrolithiasis patients and normal subjects at 20-50 ages. We thought that in these patients had high fracture rates determined previous studies especially in older ages, bone metabolic and geometric changes may start or/and fast with aging together other cause of loss of bone mineral (e.g. postmenopausal osteoporosis.

  10. Concept of effective atomic number and effective mass density in dual-energy X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bonnin, Anne, E-mail: annebonnin@free.fr [ESRF, 6 Jules Horowitz, F-38073 Grenoble Cedex (France); LVA, Vibrations and Acoustic Laboratory, INSA-Lyon, Université de Lyon, F-69621 Villeurbanne Cedex (France); Duvauchelle, Philippe, E-mail: philippe.duvauchelle@insa-lyon.fr [LVA, Vibrations and Acoustic Laboratory, INSA-Lyon, Université de Lyon, F-69621 Villeurbanne Cedex (France); Kaftandjian, Valérie [LVA, Vibrations and Acoustic Laboratory, INSA-Lyon, Université de Lyon, F-69621 Villeurbanne Cedex (France); Ponard, Pascal [Thales Electron Devices SAS, 2 Rue Marcel Dassault, BP23 78141 Vélizy, Villacoublay Cedex (France)

    2014-01-01

    This paper focuses on dual-energy X-ray computed tomography and especially the decomposition of the measured attenuation coefficient in a mass density and atomic number basis. In particular, the concept of effective atomic number is discussed. Although the atomic number is well defined for chemical elements, the definition of an effective atomic number for any compound is not an easy task. After reviewing different definitions available in literature, a definition related to the method of measurement and X-ray energy, is suggested. A new concept of effective mass density is then introduced in order to characterize material from dual-energy computed tomography. Finally, this new concept and definition are applied on a simulated case, focusing on explosives identification in luggage.

  11. Bone mineral density in renal osteodystrophy: Comparison of dual energy X-ray absorptiometry and quantitative computed tomography. Vergleichende Untersuchungen mit der quantitativen Computertomographie und der Dual-Energy-X-Ray-Absorptiometrie zur Knochendichte bei renaler Osteopathie

    Energy Technology Data Exchange (ETDEWEB)

    Funke, M.; Maeurer, J.; Grabbe, E. (Abt. Roentgendiagnostik, Klinikum, Goettingen Univ. (Germany)); Scheler, F. (Abt. Nephrologie und Rheumatologie, Klinikum, Goettingen Univ. (Germany))

    1992-08-01

    Measurements of bone density were carried out in 25 patients on dialysis for terminal renal insufficiency, using quantitative computed tomography (QCT) and dual energy X-ray absorptiometry (DXA). Unlike in subjects with normal kidneys, there was no significant correlation between these methods in this series. Ten patients showed an increase in bone density of the vertebral spongiosa on QCT measurements, which was interpreted as due to osteosclerotic bone changes in renal osteopathy. QCT showed advantages over DXA in demonstrating these changes. (orig.).

  12. Calibration of the Nustar High-Energy Focusing X-Ray Telescope

    DEFF Research Database (Denmark)

    Madsen, Kristin K.; Harrison, Fiona A.; Markwardt, Craig B.

    2015-01-01

    We present the calibration of the Nuclear Spectroscopic Telescope Array (NuSTAR) X-ray satellite. We used the Crab as the primary effective area calibrator and constructed a piece-wise linear spline function to modify the vignetting response. The achieved residuals for all off-axis angles...

  13. Improvements in the management of rheumatic patients from vertebral image obtained through dual-energy X-ray absorptiometry

    Directory of Open Access Journals (Sweden)

    D. Gatti

    2011-09-01

    Full Text Available The diagnosis of asymptomatic vertebral fracture is clinically useful and the identification of new fractures may influences the choice of appropriate therapeutic measures. In order to identify moderate and asymptomatic vertebral deformities in an objective and reproducible manner, vertebral morphometry is performed. This method measures the vertebral body’s anterior, middle and posterior heights at the dorsal and lumbar level. Currently this technique is performed on lateral images of the spine obtained through the traditional X-ray method (radiological morphometry or morphometric X-ray radiography, MRX and, more recently from images obtained through dual-energy X-ray absorptiometry (DXA machines (visual assessment of x-ray absoptiometry scans or morphometric X-ray absorptiometry, MXA, commonly used to measure bone mineral density. The main advantage of MXA relative to MRX is the lower radiation dose to which the patient is exposed during the exam. In addition, MXA scans offers the advantage of acquiring a single image of thoracic and lumbar spine, without any distortion (e.g.: coning. The most obvious advantage of MXA is the opportunity of obtaining during the same session a bone mineral density evaluation, and digital images that are easily processable, manageable, recordable and comparable for the patient’s follow up. A limitation of the MXA technique is the inferior quality of the images, that make often impossible the detection of the vertebral edges, and the impossibility to visualize the upper thoracic vertebral bodies. MXA, despite its intrinsic limitations, when carried out by trained personnel may provide substantial improvements in the management (diagnosis and follow-up of rheumatic patients.

  14. Calibration of thickness-dependent k-factors for germanium X-ray lines to improve energy-dispersive X-ray spectroscopy of SiGe layers in analytical transmission electron microscopy

    OpenAIRE

    Qiu, Yi; Nguyen, Huy; A. Dobbie; Myronov, Maksym; Walther, T.

    2013-01-01

    We show that the accuracy of energy-dispersive X-ray spectroscopy can be improved by analysing and comparing multiple lines from the same element. For each line, an effective k-factor can be defined that varies as a function of the intensity ratio of multiple lines (e.g. K/L) from the same element. This basically performs an internal self-consistency check in the quantification using differently absorbed X-ray lines, which is in principle equivalent to an absorption correction as a function o...

  15. MACHOs and the diffuse X-ray background

    Science.gov (United States)

    Kashyap, V.; Rosner, R.; Schramm, D.; Truran, J.

    1994-01-01

    The possible contribution of X-ray emission from massive compact objects in the Galactic halo (MACHOs) to the diffuse X-ray background is explored. We show that such emission cannot be responsible for the shadowing seen in soft X-ray observations by ROSAT but that these objects may indeed contribute significantly (at levels greater than 10%) to the diffuse background at higher (greater than or approximately 0.5 keV) energies. Thus, X-ray observations may well be able to significantly constrain the spatial distribution of MACHOs.

  16. Development of Multilayer Coatings for Hard X-Ray Optics at NASA Marshall Space Flight Center

    Science.gov (United States)

    Gurgew, Danielle N.; Broadway, David M.; Ramsey, Brian; Gregory, Don

    2017-01-01

    Broadband X-ray multilayer coatings are under development at NASA MSFC for use on future astronomical X-ray telescopes. Multilayer coatings deposited onto the reflecting surfaces of X-ray optics can provide a large bandpass enabling observations of higher energy astrophysical objects and phenomena.

  17. A Dedicated dual energy X-ray tomography/radiography equipment on-board of R/V Mare Nigrum

    Energy Technology Data Exchange (ETDEWEB)

    Iovea, M.; Neagu, M. [Accent Pro 2000, Ltd, Bucharest (Romania); Duliu, O.G. [Bucharest Univ., Dept. of Atomic and Nuclear Physics (Romania); Oaie, G. [National Institute of Marine Geology and Geoecology, Bucharet (Romania); Mateiasi, G. [Bucharest Politehnica Univ. (Romania)

    2007-07-01

    An X-ray dual-energy computer tomograph provided with a double set of X-ray detectors arrays separated by a copper foil was projected, assembled and commissioned to be used on-board of the R/V Mare Nigrum. By using a variant of filtered back projections reconstruction algorithm together with a set of calibrated standard samples, it was possible do determine on-board and with a precision of 3.5 % the density and 2.5 % the effective atomic number distribution of various unconsolidated sediments core. The same computer tomograph was used to obtain free of parallax dual energy digital radiography, allowing a spatial resolution of about 0.5 mm. (authors)

  18. Complete polarization analysis of high energy soft x-rays by combining a multilayer phase retarder with crystal analyzer

    Science.gov (United States)

    Wang, H.; Dhesi, S. S.; Maccherozzi, F.; Sawhney, K. J. S.

    2012-06-01

    We demonstrate a complete polarization analysis of soft x-rays with an energy of 1.1 keV using a free-standing W/B4C multilayer phase retarders and a beryl crystal analyzer. The W/B4C multilayer exhibits five times increase in transmission over that previously reported. The beryl crystal proves to be a suitable analyzer for the polarization analysis with a 10% s-component of reflectivity resulting in an extinction ratio close to 0.002 at 1.1 keV. The combination of multilayer phase retarders and crystal analyzers should open up the field of the soft x-ray polarization analysis in the energy range between 1 keV and 2 keV.

  19. Studying Dark Energy, Black Holes and Cosmic Feedback at X-ray Wavelengths: NASA's Constellation-X Mission

    Science.gov (United States)

    Hornschemeier, A.

    2005-01-01

    Among the most important topics in modern astrophysics are the nature of the dark energy equation of state, the formation and evolution of supermassive black holes in concert with galaxy bulges, and the self-regulating symmetry imposed by both stellar and AGN feedback. All of these topics are readily addressed with observations at X-ray wavelengths. For instance, theoretical models predict that the majority (98%) of the energy and metal content in starburst superwinds exists in the hot million-degree gas. The Constellation-X observatory is being developed to perform spatially resolved high-resolution X-ray spectroscopy so that we may directly measure the absolute element abundances and velocities of this hot gas. This talk focuses on the driving science behind this mission, which is one of two flagship missions in NASA's Beyond Einstein program. A general overview of the observatory's capabilities and basic technology will also be given.

  20. Quantifying the Nucleation and Growth Kinetics of Microwave Nanochemistry Enabled by in Situ High-Energy X-ray Scattering.

    Science.gov (United States)

    Liu, Qi; Gao, Min-Rui; Liu, Yuzi; Okasinski, John S; Ren, Yang; Sun, Yugang

    2016-01-13

    The fast reaction kinetics presented in the microwave synthesis of colloidal silver nanoparticles was quantitatively studied, for the first time, by integrating a microwave reactor with in situ X-ray diffraction at a high-energy synchrotron beamline. Comprehensive data analysis reveals two different types of reaction kinetics corresponding to the nucleation and growth of the Ag nanoparticles. The formation of seeds (nucleation) follows typical first-order reaction kinetics with activation energy of 20.34 kJ/mol, while the growth of seeds (growth) follows typical self-catalytic reaction kinetics. Varying the synthesis conditions indicates that the microwave colloidal chemistry is independent of concentration of surfactant. These discoveries reveal that the microwave synthesis of Ag nanoparticles proceeds with reaction kinetics significantly different from the synthesis present in conventional oil bath heating. The in situ X-ray diffraction technique reported in this work is promising to enable further understanding of crystalline nanomaterials formed through microwave synthesis.

  1. Assessment of body composition by dual-energy X-ray absorptiometry, bioimpedance analysis and anthropometrics in children

    DEFF Research Database (Denmark)

    Tompuri, Tuomo T; Lakka, Timo A; Hakulinen, Mikko

    2015-01-01

    We compared InBody720 segmental multifrequency bioimpedance analysis (SMF-BIA) with Lunar Prodigy Advance dual-energy X-ray absorptiometry (DXA) in assessment of body composition among 178 predominantly prepubertal children. Segmental agreement analysis of body compartments was carried out......, and inter-relationships of anthropometric and other measures of body composition were defined. Moreover, the relations of different reference criteria for excess body fat were evaluated....

  2. Calibration of a High Resolution X-ray Spectrometer for High-Energy-Density Plasmas on NIF

    Science.gov (United States)

    Kraus, B.; Gao, L.; Hill, K. W.; Bitter, M.; Efthimion, P.; Schneider, M. B.; Chen, H.; Ayers, J.; Beiersdorfer, P.; Liedahl, D.; Macphee, A. G.; Thorn, D. B.; Bettencourt, R.; Kauffman, R.; Le, H.; Nelson, D.

    2017-10-01

    A high-resolution, DIM-based (Diagnostic Instrument Manipulator) x-ray crystal spectrometer has been calibrated for and deployed at the National Ignition Facility (NIF) to diagnose plasma conditions and mix in ignition capsules near stagnation times. Two conical crystals in the Hall geometry focus rays from the Kr He- α, Ly- α, and He- β complexes onto a streak camera for time-resolved spectra, in order to measure electron density and temperature by observing Stark broadening and relative intensities of dielectronic satellites. Signals from these two crystals are correlated with a third crystal that time-integrates the intervening energy range. The spectrometer has been absolutely calibrated using a microfocus x-ray source, an array of CCD and single-photon-counting detectors, and K- and L-absorption edge filters. Measurements of the integrated reflectivity, energy range, and energy resolution for each crystal will be presented. The implications of the calibration on signal levels from NIF implosions and x-ray filter choices will be discussed. This work was performed under the auspices of the U.S. DoE by Princeton Plasma Physics Laboratory under contract DE-AC02-09CH11466 and by Lawrence Livermore National Laboratory under contract DE-AC52-07NA27344.

  3. A new pnCCD-based color X-ray camera for fast spatial and energy-resolved measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ordavo, I., E-mail: ivan.ordavo@pnsensor.de [PNSensor GmbH, Roemerstrasse 28, 80803 Muenchen (Germany); PNDetector GmbH, Emil-Nolde-Strasse 10, 81735 Muenchen (Germany); Ihle, S. [PNSensor GmbH, Roemerstrasse 28, 80803 Muenchen (Germany); Arkadiev, V. [Institut fuer angewandte Photonik e.V., Rudower Chaussee 29/31, 12489 Berlin (Germany); Scharf, O. [BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter-Strasse 11, 12489 Berlin (Germany); Soltau, H. [PNSensor GmbH, Roemerstrasse 28, 80803 Muenchen (Germany); Bjeoumikhov, A.; Bjeoumikhova, S. [IFG - Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany); Buzanich, G. [BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter-Strasse 11, 12489 Berlin (Germany); Gubzhokov, R.; Guenther, A. [IFG - Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany); Hartmann, R.; Holl, P. [PNSensor GmbH, Roemerstrasse 28, 80803 Muenchen (Germany); Kimmel, N. [Max-Planck-Institut fuer extraterrestrische Physik, Giessenbachstrasse, 85748 Garching (Germany); Max-Planck-Institut Halbleiterlabor, Otto-Hahn-Ring 6, 81739 Muenchen (Germany); Kuehbacher, M. [Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Lang, M. [PNSensor GmbH, Roemerstrasse 28, 80803 Muenchen (Germany); Langhoff, N. [IFG - Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany); Liebel, A. [PNDetector GmbH, Emil-Nolde-Strasse 10, 81735 Muenchen (Germany); Radtke, M.; Reinholz, U.; Riesemeier, H. [BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter-Strasse 11, 12489 Berlin (Germany); and others

    2011-10-21

    We present a new high resolution X-ray imager based on a pnCCD detector and a polycapillary optics. The properties of the pnCCD like high quantum efficiency, high energy resolution and radiation hardness are maintained, while color corrected polycapillary lenses are used to direct the fluorescence photons from every spot on a sample to a corresponding pixel on the detector. The camera is sensitive to photons from 3 to 40 keV with still 30% quantum efficiency at 20 keV. The pnCCD is operated in split frame mode allowing a high frame rate of 400 Hz with an energy resolution of 152 eV for Mn K{alpha} (5.9 keV) at 450 kcps. In single-photon counting mode (SPC), the time, energy and position of every fluorescence photon is recorded for every frame. A dedicated software enables the visualization of the elements distribution in real time without the need of post-processing the data. A description of the key components including detector, X-ray optics and camera is given. First experiments show the capability of the camera to perform fast full-field X-Ray Fluorescence (FF-XRF) for element analysis. The imaging performance with a magnifying optics (3x) has also been successfully tested.

  4. Upper and lower limbs composition: a comparison between anthropometry and dual-energy X-ray absorptiometry in healthy people.

    Science.gov (United States)

    Diano, Danila; Ponti, Federico; Guerri, Sara; Mercatelli, Daniele; Amadori, Michele; Aparisi Gómez, Maria Pilar; Battista, Giuseppe; Guglielmi, Giuseppe; Bazzocchi, Alberto

    2017-09-18

    The detection of changes in lean mass (LM) distribution can help to prevent disability. This study assessed the degree of association between anthropometric measurements and dual-energy X-ray absorptiometry (DXA) body composition (BC) parameters of the upper and lower limbs in a healthy general population and collected DXA age- and sex-specific values of BC that can be useful to build a reference standard. The primary aim of this study was to investigate the reliability of some widely available anthropometric measurements in the assessment of body composition (BC) at the limbs, especially in terms of muscle mass, in a large sample of healthy subjects of different age bands and sex, using fat mass (FM) and lean mass (LM) parameters derived by dual-energy X-ray absorptiometry (DXA) as the gold standard. The secondary aim was to collect DXA age- and sex-specific values of BC of left and right limbs (upper and lower) in a healthy Italian population to be used as reference standards. Two hundred fifty healthy volunteers were enrolled. Arm circumference (AC) and thigh circumference (ThC) were measured, and total and regional BC parameters were obtained by a whole-body DXA scan (Lunar iDXA, Madison, WI, USA; enCORE™ 2011 software version 13.6). FM/LM showed only fair correlation with AC and ThC in females (r = 0.649 and 0.532, respectively); in males and in the total population, the correlation was low (r = 0.360 or lower, and p non-statistically significant). AC and ThC were not well representative of arms LM in both genders (females r = 0.452, males r = 0.530) independently of age. In general, men of all age groups showed higher values of LM and lean mass index (LMI) in both total and segmental upper and lower limbs. In males, the maximum LM and LMI were achieved in the fifth decade in both upper and lower limbs and then started to decrease with aging. In females, no significant modification with aging was identified in LM and LMI. According to our results

  5. Trace elements as tumor biomarkers and prognostic factors in breast cancer: a study through energy dispersive x-ray fluorescence

    Science.gov (United States)

    2012-01-01

    Background The application and better understanding of traditional and new breast tumor biomarkers and prognostic factors are increasing due to the fact that they are able to identify individuals at high risk of breast cancer, who may benefit from preventive interventions. Also, biomarkers can make possible for physicians to design an individualized treatment for each patient. Previous studies showed that trace elements (TEs) determined by X-Ray Fluorescence (XRF) techniques are found in significantly higher concentrations in neoplastic breast tissues (malignant and benign) when compared with normal tissues. The aim of this work was to evaluate the potential of TEs, determined by the use of the Energy Dispersive X-Ray Fluorescence (EDXRF) technique, as biomarkers and prognostic factors in breast cancer. Methods By using EDXRF, we determined Ca, Fe, Cu, and Zn trace elements concentrations in 106 samples of normal and breast cancer tissues. Cut-off values for each TE were determined through Receiver Operating Characteristic (ROC) analysis from the TEs distributions. These values were used to set the positive or negative expression. This expression was subsequently correlated with clinical prognostic factors through Fisher’s exact test and chi-square test. Kaplan Meier survival curves were also evaluated to assess the effect of the expression of TEs in the overall patient survival. Results Concentrations of TEs are higher in neoplastic tissues (malignant and benign) when compared with normal tissues. Results from ROC analysis showed that TEs can be considered a tumor biomarker because, after establishing a cut-off value, it was possible to classify different tissues as normal or neoplastic, as well as different types of cancer. The expression of TEs was found statistically correlated with age and menstrual status. The survival curves estimated by the Kaplan-Meier method showed that patients with positive expression for Cu presented a poor overall survival (p

  6. Repetitive flash x-ray generator utilizing a simple diode with a new type of energy-selective function

    Science.gov (United States)

    Sato, E.; Kimura, S.; Kawasaki, S.; Isobe, H.; Takahashi, K.; Tamakawa, Y.; Yanagisawa, T.

    1990-09-01

    The construction and the fundamental studies of a repetitive flash x-ray generator having a simple diode with an energy-selective function are described. This generator consisted of the following components: a constant high-voltage power supply, a high-voltage pulser, a repetitive high-energy impulse switching system, a turbo molecular pump, and a flash x-ray tube. The circuit of this pulser employed a modified two-stage surge Marx generator with a capacity during main discharge of 425pF. The x-ray tube was of the demountable-diode type which was connected to the turbo molecular pump and consisted of the following major devices: a rod-shaped anode tip made of tungsten, a disk cathode made of graphite, an aluminum filter, and a tube body made of glass. Two condensers inside of the pulser were charged from 40 to 60 kV, and the output voltage was about 1.9 times the charging voltage. The peak tube voltage was primarily determined by the anode-cathode (A-C) space, and the peak tube current was less than 0.6 kA. The peak tube voltage slightly increased when the charging voltage was increased, but the amount of change rate was small. Thus, the maximum photon energy could be easily controlled by varying the A-C space. The pulse width ranged from 40 to 100 ns, and the x-ray intensity was less than 1.0 μC/kg at 0.3 m per pulse. The repetitive frequency was less than 50 Hz, and the effective focal spot size was determined by the diameter of the anode tip and ranged from 0.5 to 3.0 mm in diameter.

  7. Algorithms for three-dimensional chemical analysis via multi-energy synchrotron X-ray tomography

    Science.gov (United States)

    Ham, Kyungmin; Butler, Leslie G.

    2007-08-01

    The conversion of X-ray tomography images into three-dimensional chemical composition requires accurate mass absorption values, high-quality images, and a robust fitting algorithm. The least-squares fits of the images to a three-dimensional chemical composition can proceed with several different options such as minimal vs. over-determined and/or constrained parameters. This project has investigated the impact of XAFS features and a limited CCD dynamic range. These simulated results are compared to a recent experimental project in which synchrotron X-ray tomography was used to image a polymer blend, and from those images, calculated three-dimensional chemical composition maps of the two-component flame retardant, a brominated phthalimide dimer, Saytex ™ BT-93 and a synergist, antimony(III) oxide (Sb 2O 3).

  8. Algorithms for three-dimensional chemical analysis via multi-energy synchrotron X-ray tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Kyungmin [Louisiana State University, Department of Chemistry, 232 Choppin Hall, Baton Rouge, LA 70803 (United States); Butler, Leslie G. [Louisiana State University, Department of Chemistry, 232 Choppin Hall, Baton Rouge, LA 70803 (United States)]. E-mail: lbutler@lsu.edu

    2007-08-15

    The conversion of X-ray tomography images into three-dimensional chemical composition requires accurate mass absorption values, high-quality images, and a robust fitting algorithm. The least-squares fits of the images to a three-dimensional chemical composition can proceed with several different options such as minimal vs. over-determined and/or constrained parameters. This project has investigated the impact of XAFS features and a limited CCD dynamic range. These simulated results are compared to a recent experimental project in which synchrotron X-ray tomography was used to image a polymer blend, and from those images, calculated three-dimensional chemical composition maps of the two-component flame retardant, a brominated phthalimide dimer, Saytex{sup {sup }}T{sup M} BT-93 and a synergist, antimony(III) oxide (Sb{sub 2}O{sub 3})

  9. Characterizing high energy spectra of NIF ignition Hohlraums using a differentially filtered high energy multipinhole x-ray imager.

    Science.gov (United States)

    Park, Hye-Sook; Dewald, E D; Glenzer, S; Kalantar, D H; Kilkenny, J D; MacGowan, B J; Maddox, B R; Milovich, J L; Prasad, R R; Remington, B A; Robey, H F; Thomas, C A

    2010-10-01

    Understanding hot electron distributions generated inside Hohlraums is important to the national ignition campaign for controlling implosion symmetry and sources of preheat. While direct imaging of hot electrons is difficult, their spatial distribution and spectrum can be deduced by detecting high energy x-rays generated as they interact with target materials. We used an array of 18 pinholes with four independent filter combinations to image entire Hohlraums with a magnification of 0.87× during the Hohlraum energetics campaign on NIF. Comparing our results with Hohlraum simulations indicates that the characteristic 10-40 keV hot electrons are mainly generated from backscattered laser-plasma interactions rather than from Hohlraum hydrodynamics.

  10. X-Ray Lasers 2016

    CERN Document Server

    Bulanov, Sergei; Daido, Hiroyuki; Kato, Yoshiaki

    2018-01-01

    These proceedings comprise a selection of invited and contributed papers presented at the 15th International Conference on X-Ray Lasers (ICXRL 2016), held at the Nara Kasugano International Forum, Japan, from May 22 to 27, 2016. This conference was part of an ongoing series dedicated to recent developments in the science and technology of x-ray lasers and other coherent x-ray sources with additional focus on supporting technologies, instrumentation and applications.   The book showcases recent advances in the generation of intense, coherent x-rays, the development of practical devices and their applications across a wide variety of fields. It also discusses emerging topics such as plasma-based x-ray lasers, 4th generation accelerator-based sources and higher harmonic generations, as well as other x-ray generation schemes.

  11. Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography

    Science.gov (United States)

    Hall, G. N.; Izumi, N.; Landen, O. L.; Tommasini, R.; Holder, J. P.; Hargrove, D.; Bradley, D. K.; Lumbard, A.; Cruz, J. G.; Piston, K.; Lee, J. J.; Romano, E.; Bell, P. M.; Carpenter, A. C.; Palmer, N. E.; Felker, B.; Rekow, V.; Allen, F. V.

    2016-11-01

    Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro-channel plate) to provide gating and high DQE at the 40-200 keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Experiments were performed at energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.

  12. Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hall, G. N., E-mail: hall98@llnl.gov; Izumi, N.; Landen, O. L.; Tommasini, R.; Holder, J. P.; Hargrove, D.; Bradley, D. K.; Lumbard, A.; Cruz, J. G.; Piston, K.; Bell, P. M.; Carpenter, A. C.; Palmer, N. E.; Felker, B.; Rekow, V.; Allen, F. V. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550 (United States); Lee, J. J.; Romano, E. [National Security Technologies LLC, 161 S Vasco Rd., Livermore, California 94551 (United States)

    2016-11-15

    Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro-channel plate) to provide gating and high DQE at the 40–200 keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Experiments were performed at energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.

  13. Retrieving the Quantitative Chemical Information at Nanoscale from Scanning Electron Microscope Energy Dispersive X-ray Measurements by Machine Learning

    Science.gov (United States)

    Jany, B. R.; Janas, A.; Krok, F.

    2017-11-01

    The quantitative composition of metal alloy nanowires on InSb(001) semiconductor surface and gold nanostructures on germanium surface is determined by blind source separation (BSS) machine learning (ML) method using non negative matrix factorization (NMF) from energy dispersive X-ray spectroscopy (EDX) spectrum image maps measured in a scanning electron microscope (SEM). The BSS method blindly decomposes the collected EDX spectrum image into three source components, which correspond directly to the X-ray signals coming from the supported metal nanostructures, bulk semiconductor signal and carbon background. The recovered quantitative composition is validated by detailed Monte Carlo simulations and is confirmed by separate cross-sectional TEM EDX measurements of the nanostructures. This shows that SEM EDX measurements together with machine learning blind source separation processing could be successfully used for the nanostructures quantitative chemical composition determination.

  14. Composition measurement in substitutionally disordered materials by atomic resolution energy dispersive X-ray spectroscopy in scanning transmission electron microscopy.

    Science.gov (United States)

    Chen, Z; Taplin, D J; Weyland, M; Allen, L J; Findlay, S D

    2017-05-01

    The increasing use of energy dispersive X-ray spectroscopy in atomic resolution scanning transmission electron microscopy invites the question of whether its success in precision composition determination at lower magnifications can be replicated in the atomic resolution regime. In this paper, we explore, through simulation, the prospects for composition measurement via the model system of AlxGa1-xAs, discussing the approximations used in the modelling, the variability in the signal due to changes in configuration at constant composition, and the ability to distinguish between different compositions. Results are presented in such a way that the number of X-ray counts, and thus the expected variation due to counting statistics, can be gauged for a range of operating conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Combined experimental powder X-ray diffraction and DFT data to obtain the lowest energy molecular conformation of friedelin

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Djalma Menezes de; Mussel, Wagner da Nova; Duarte, Lucienir Pains; Silva, Gracia Divina de Fatima; Duarte, Helio Anderson; Gomes, Elionai Cassiana de Lima [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Quimica; Guimaraes, Luciana [Universidade Federal de Sao Joao Del-Rei (UFSJ), MG (Brazil). Dept. de Ciencias Naturais; Vieira Filho, Sidney A., E-mail: bibo@ef.ufop.br [Universidade Federal de Ouro Preto (UFOP), MG (Brazil). Dept. de Farmacia

    2012-07-01

    Friedelin molecular conformers were obtained by Density Functional Theory (DFT) and by ab initio structure determination from powder X-ray diffraction. Their conformers with the five rings in chair-chair-chair-boat-boat, and with all rings in chair, are energy degenerated in gas-phase according to DFT results. The powder diffraction data reveals that rings A, B and C of friedelin are in chair, and rings D and E in boat-boat, conformation. The high correlation values among powder diffraction data, DFT and reported single crystal data indicate that the use of conventional X-ray diffractometer can be applied in routine laboratory analysis in the absence of a single-crystal diffractometer. (author)

  16. Combined experimental powder X-ray diffraction and DFT data to obtain the lowest energy molecular conformation of friedelin

    Directory of Open Access Journals (Sweden)

    Djalma Menezes de Oliveira

    2012-01-01

    Full Text Available Friedelin molecular conformers were obtained by Density Functional Theory (DFT and by ab initio structure determination from powder X-ray diffraction. Their conformers with the five rings in chair-chair-chair-boat-boat, and with all rings in chair, are energy degenerated in gas-phase according to DFT results. The powder diffraction data reveals that rings A, B and C of friedelin are in chair, and rings D and E in boat-boat, conformation. The high correlation values among powder diffraction data, DFT and reported single-crystal data indicate that the use of conventional X-ray diffractometer can be applied in routine laboratory analysis in the absence of a single-crystal diffractometer.

  17. Uranium aerosols at a nuclear fuel fabrication plant: Characterization using scanning electron microscopy and energy dispersive X-ray spectroscopy

    Science.gov (United States)

    Hansson, E.; Pettersson, H. B. L.; Fortin, C.; Eriksson, M.

    2017-05-01

    Detailed aerosol knowledge is essential in numerous applications, including risk assessment in nuclear industry. Cascade impactor sampling of uranium aerosols in the breathing zone of nuclear operators was carried out at a nuclear fuel fabrication plant. Collected aerosols were evaluated using scanning electron microscopy and energy dispersive X-ray spectroscopy. Imaging revealed remarkable variations in aerosol morphology at the different workshops, and a presence of very large particles (up to ≅ 100 × 50 μm2) in the operator breathing zone. Characteristic X-ray analysis showed varying uranium weight percentages of aerosols and, frequently, traces of nitrogen, fluorine and iron. The analysis method, in combination with cascade impactor sampling, can be a powerful tool for characterization of aerosols. The uranium aerosol source term for risk assessment in nuclear fuel fabrication appears to be highly complex.

  18. Trace elements determination by energy dispersive X-ray fluorescence (EDXRF) in human placenta and membrane: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Custodio, P.J.; Carvalho, M.L. [Centro Fisica Atomica, Universidade de Lisboa, Av. Prof. Gama Pinto, 2, 1649-003, Lisboa (Portugal); Nunes, F. [Hospital Garcia de Orta, Almada (Portugal)

    2003-04-01

    This work is an application of energy dispersive X-ray fluorescence (EDXRF) as an analytical technique for trace elemental determination in human membrane and placenta and elemental concentrations correlations in both tissues. Whole samples were collected during the delivery from healthy mothers and full-term pregnancies. The age of the mother was between 25 and 40 years old, and the weight of the infants ranged from 2.56 to 4.05 kg. Samples were lyophilised and analysed without any chemical treatment. No significant differences in elemental content of placenta and membrane samples were observed except for Ca. Very low levels of Se, As and Pb were observed in all the analysed samples. Zn, considered as one of the key elements in newborn health, was not significantly different in the analysed samples, all of which originated from healthy mothers and healthy babies. The obtained values agree with the literature except for Ca, which is much higher in the studied samples. (orig.)

  19. Magnetic resonance imaging and dual energy X-ray absorptiometry of the lumbar spine in professional wrestlers and untrained men.

    Science.gov (United States)

    Hu, M; Sheng, J; Kang, Z; Zou, L; Guo, J; Sun, P

    2014-08-01

    The aim of this study was to examine the relation between bone marrow adipose tissue (BMAT) and bone mineral density (BMD) of lumbar spine in male professional wrestlers and healthy untrained men. A total of 14 wrestlers (22.9±3.4 years) and 11 controls (24.4±1.6 years) were studied cross-sectionally. Body composition and BMD were measured by dual-energy X-ray absorptiometry. Magnetic resonance imaging of the lumbar spine was examined in a sagittal T1-weighted (T1-w) spin-echo (SE) sequence. The averaged bone marrow signal intensity (SI) of L2-L4 was related to the signal of an adjacent nondegenerative disk. Mean SI of T1-w SE in wrestlers was lower than controls (P=0.001), indicating L2-L4 BMAT in wrestlers was lower compared to controls. L2-L4 BMD in wrestlers was higher than controls (Ptraining is an important determinant of this association.

  20. Body composition in male elite athletes, comparison of bioelectrical impedance spectroscopy with dual energy X-ray absorptiometry

    Directory of Open Access Journals (Sweden)

    Klingberg Sofia

    2008-01-01

    Full Text Available Abstract Background The aim of this study was to compare body composition results from bioelectrical spectroscopy (BIS with results from dual energy X-ray absorptiometry (DXA in a population of male elite athletes. Body composition was assessed using DXA (Lunar Prodigy, GE Lunar Corp., Madison, USA and BIS (Hydra 4200, Xitron Technologies Inc, San Diego, California, USA at the same occasion. Agreement between methods was assessed using paired t-tests and agreement-plots. Results Thirty-three male elite athletes (soccer and ice hockey were included in the study. The results showed that BIS underestimates the proportion of fat mass by 4.6% points in the ice hockey players. In soccer players the BIS resulted in a lower mean fat mass by 1.1% points. Agreement between the methods at the individual level was highly variable. Conclusion Body composition results assessed by BIS in elite athletes should be interpreted with caution, especially in individual subjects. BIS may present values of fat mass that is either higher or lower than fat mass assessed by DXA, independent of true fat content of the individual.

  1. Comparison of Bioelectrical Impedance Analysis and Dual Energy X-ray Absorptiometry for Estimating Bone Mineral Content.

    Science.gov (United States)

    Stone, Tori M; Wingo, Jonathan E; Nickerson, Brett S; Esco, Michael R

    2018-01-18

    The purpose of this study was to validate single-frequency hand-to-foot bioelectrical impedance analysis (HFBIA) for estimating bone mineral content (BMC) using dual energy X-ray absorptiometry (DXA) as the criterion measure in healthy, men and women aged 18-40 y. A total of 80 men and women participated. Bone mineral content was estimated on the same day using HFBIA and DXA. HFBIA device provided higher mean BMC values in men and the entire sample, but not in women. A smaller standard error of estimate was observed in women (0.20, corresponding to 8% of the mean reference BMC values) compared to men (0.39, corresponding to 12% of the mean reference BMC values) and the combined sample (0.31). HFBIA provided a smaller constant error and individual estimation error indicated by the 95% limits of agreement in women (-0.05 ± 0.39) compared to the men (-0.16 ± 0.78) and entire sample (-0.10 ± 0.63). In conclusion, although BMC values were found to be more accurate in women, HFBIA overestimated BMC compared to DXA, especially in individuals with lower values. Given these results, using HFBIA to measure BMC would be inappropriate for diagnostic purposes.

  2. Quality indexes based on water measurements for low and medium energy x-ray beams: A theoretical study with PENELOPE

    Energy Technology Data Exchange (ETDEWEB)

    Chica, U. [Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada, Spain and FISRAD S.A.S Carrera 64 a No 22-41, Bogotá D.C. (Colombia); Anguiano, M.; Lallena, A. M., E-mail: lallena@ugr.es [Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada (Spain); Vilches, M. [Servicio de Radiofísica, Hospital Universitario “San Cecilio”, Avda. Dr. Olóriz, 16, E-18012 Granada (Spain)

    2014-01-15

    Purpose : To study the use of quality indexes based on ratios of absorbed doses in water at two different depths to characterize x-ray beams of low and medium energies. Methods : A total of 55 x-ray beam spectra were generated with the codes XCOMP5R and SPEKCALC and used as input of a series of Monte Carlo simulations performed with PENELOPE, in which the percentage depth doses in water and thek{sub Q,Q{sub 0}} factors, defined in the TRS-398 protocol, were determined for each beam. Some of these calculations were performed by simulating the ionization chamber PTW 30010. Results : The authors found that the relation betweenk{sub Q,Q{sub 0}} and the ratios of absorbed doses at two depths is almost linear. A set of ratios statistically compatible with that showing the best fit has been determined. Conclusions : The results of this study point out which of these ratios of absorbed doses in water could be used to better characterize x-ray beams of low and medium energies.

  3. Measurements of internal stresses in bond coating using high energy x-rays from synchrotron radiation source

    CERN Document Server

    Suzuki, K; Akiniwa, Y; Nishio, K; Kawamura, M; Okado, H

    2002-01-01

    Thermal barrier coating (TBC) techniques enable high temperature combustion of turbines made of Ni-base alloy. TBC is made of zirconia top coating on NiCoCrAlY bond coating. The internal stresses in the bond coating play essential role in the delamination or fracture of TBC in service. With the X-rays from laboratory equipments, it is impossible to measure nondestructively the internal stress in the bond coating under the top coating. synchrotron radiations with a high energy and high brightness have a large penetration depth as compared with laboratory X-rays. Using the high energy X-rays from the synchrotron radiation, it is possible to measure the internal stress in the bond coating through the top coating. In this study, the furnace, which can heat a specimen to 1473 K, was developed for the stress measurement of the thermal barrier coatings. The internal stresses in the bond coating were measured at the room temperature, 773 K, 1073 K and 1373 K by using the 311 diffraction from Ni sub 3 Al with about 73...

  4. Single-shot structural analysis by high-energy X-ray diffraction using an ultrashort all-optical source.

    Science.gov (United States)

    Rakowski, R; Golovin, G; O'Neal, J; Zhang, J; Zhang, P; Zhao, B; Wilson, M D; Veale, M C; Seller, P; Chen, S; Banerjee, S; Umstadter, D; Fuchs, M

    2017-11-30

    High-energy X-rays (HEX-rays) with photon energies on order of 100 keV have attractive characteristics, such as comparably low absorption, high spatial resolution and the ability to access inner-shell states of heavy atoms. These properties are advantageous for many applications ranging from studies of bulk materials to the investigation of materials in extreme conditions. Ultrafast X-ray diffraction allows the direct imaging of atomic dynamics simultaneously on its natural time and length scale. However, using HEX-rays for ultrafast studies has been limited due to the lack of sources that can generate pulses of sufficiently short (femtosecond) duration in this wavelength range. Here we show single-crystal diffraction using ultrashort ~90 keV HEX-ray pulses generated by an all-optical source based on inverse Compton scattering. We also demonstrate a method for measuring the crystal lattice spacing in a single shot that contains only ~105 photons in a spectral bandwidth of ~50% full width at half maximum (FWHM). Our approach allows us to obtain structural information from the full X-ray spectrum. As target we use a cylindrically bent Ge crystal in Laue transmission geometry. This experiment constitutes a first step towards measurements of ultrafast atomic dynamics using femtosecond HEX-ray pulses.

  5. Radiation effects for high-energy protons and X-ray in integrated circuits

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, M.A.G.; Santos, R.B.B. [Centro Universitario da FEI, Sao Bernardo do Campo, SP (Brazil); Medina, N.H.; Added, N.; Tabacniks, M.H. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica; Lima, J.A. de [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil); Cirne, K.H. [Empresa Brasileira de Aeronautica S.A. (EMBRAER), Sao Jose dos Campos, SP (Brazil)

    2012-07-01

    Full text: Electronic circuits are strongly influenced by ionizing radiation. The necessity to develop integrated circuits (IC's) featuring radiation hardness is largely growing to meet the stringent environment in space electronics [1]. This work aims to development a test platform to qualify electronic devices under the influence of high radiation dose, for aerospace applications. To understand the physical phenomena responsible for changes in devices exposed to ionizing radiation several kinds of radiation should then be considered, among them heavy ions, alpha particles, protons, gamma and X-rays. Radiation effects on the ICs are usually divided into three categories: Total Ionizing Dose (TID), a cumulative dose that shifts the threshold voltage and increases transistor's off-state current; Single Events Effects (SEE), a transient effect which can deposit charge directly into the device and disturb the properties of electronic circuits and Displacement Damage (DD) which can change the arrangement of the atoms in the lattice [2]. In this study we are investigating the radiation effects in rectangular-gate and circular-gate MOSFETs, manufactured with standard CMOS fabrication process, using particle beams produced in electrostatic tandem accelerators and X-rays. Initial tests for TID effects were performed using the 1.7 MV 5SDH tandem Pelletron accelerator of the Instituto de Fisica da USP with a proton beam of 2.6 MeV. The devices were exposed to different doses, varying the beam current, and irradiation time with the accumulated dose reaching up to Grad. To study the effect of X-rays on the electronic devices, an XRD-7000 (Shimadzu) X-ray setup was used as a primary X-ray source. The devices were irradiated with a total dose from krad to Grad using different dose rates. The results indicate that changes of the I-V characteristic curve are strongly dependents on the geometry of the devices. [1] Duzellier, S., Aerospace Science and Technology 9, p. 93

  6. Air Kerma Calibration Factors and kch Values for PTW Soft X-ray, NACP and Roos Ionization Chambers at Very Low X-ray Energies (0.035 mm - 1.0 mm Al HVL)

    Energy Technology Data Exchange (ETDEWEB)

    Ipe, Nisy E.

    1999-07-08

    Several national and international protocols have been established for the dosimetry of x-ray beams used in radiotherapy. For the very low energy x-rays (0.035mm-1.0 mm Al HVL) only two codes are available: the UK IPEMB Code of Practice and the German standard, DIN 6809 Part 4. The measurement of very low energy x-ray beams is normally performed with parallel plate ionization chambers calibrated at a standards laboratory and characterized by an air kerma calibration factor N{sub k}. According to the IPEMB Code of Practice the absorbed dose in the user's beam should be determined by taking measurements with the parallel plate chamber positioned such that its entrance window is at the surface of a full-scatter water equivalent phantom. The absorbed dose to water can then be determined using an equation which includes a factor, k{sub ch}, which accounts for the change in response of the ionization chamber between the calibration in air and measurement at the surface of the phantom. N{sub k} and k{sub ch} values for the PTW soft X-ray, NACP and Roos ionization chambers are reported. It was found that k{sub ch} values varied from about 1.01 to 1.08 depending on the chamber, beam quality and phantom material. It is recommended that the IPEMB Code of Practice should be revised to incorporate these values.

  7. In situ flow cell for combined X-ray absorption spectroscopy, X-ray diffraction, and mass spectrometry at high photon energies under solar thermochemical looping conditions

    Science.gov (United States)

    Rothensteiner, Matthäus; Jenni, Joel; Emerich, Hermann; Bonk, Alexander; Vogt, Ulrich F.; van Bokhoven, Jeroen A.

    2017-08-01

    An in situ/operando flow cell for transmission mode X-ray absorption spectroscopy (XAS), X-ray diffraction (XRD), and combined XAS/XRD measurements in a single experiment under the extreme conditions of two-step solar thermochemical looping for the dissociation of water and/or carbon dioxide was developed. The apparatus exposes materials to relevant conditions of both the auto-reduction and the oxidation sub-steps of the thermochemical cycle at ambient temperature up to 1773 K and enables determination of the composition of the effluent gases by online quadrupole mass spectrometry. The cell is based on a tube-in-tube design and is heated by means of a focusing infrared furnace. It was tested successfully for carbon dioxide splitting. In combined XAS/XRD experiments with an unfocused beam, XAS measurements were performed at the Ce K edge (40.4 keV) and XRD measurements at 64.8 keV and 55.9 keV. Furthermore, XRD measurements with a focused beam at 41.5 keV were carried out. Equimolar ceria-hafnia was auto-reduced in a flow of argon and chemically reduced in a flow of hydrogen/helium. Under reducing conditions, all cerium(iv) was converted to cerium(iii) and a cation-ordered pyrochlore-type structure was formed, which was not stable upon oxidation in a flow of carbon dioxide.

  8. Combining flat crystals, bent crystals and compound refractive lenses for high-energy X-ray optics.

    Science.gov (United States)

    Shastri, S D

    2004-03-01

    Compound refractive lenses (CRLs) are effective for collimating or focusing high-energy X-ray beams (50-100 keV) and can be used in conjunction with crystal optics in a variety of configurations, as demonstrated at the 1-ID undulator beamline of the Advanced Photon Source. As a primary example, this article describes the quadrupling of the output flux when a collimating CRL, composed of cylindrical holes in aluminium, is inserted between two successive monochromators, i.e. a modest-energy-resolution premonochromator followed by a high-resolution monochromator. The premonochromator is a cryogenically cooled divergence-preserving bent double-Laue Si(111) crystal device delivering an energy width DeltaE/E approximately 10(-3), which is sufficient for most experiments. The high-resolution monochromator is a four-reflection flat Si(111) crystal system resembling two channel-cuts in a dispersive arrangement, reducing the bandwidth to less than 10(-4), as required for some applications. Tests with 67 and 81 keV photon energies show that the high-resolution monochromator, having a narrow angular acceptance of a few microradians, exhibits a fourfold throughput enhancement due to the insertion of a CRL that reduces the premonochromatized beam's vertical divergence from 29 micro rad to a few microradians. The ability to focus high-energy X-rays with CRLs having long focal lengths (tens of meters) is also shown by creating a line focus of 70-90 micro m beam height in the beamline end-station with both the modest-energy-resolution and the high-energy-resolution monochromatic X-rays.

  9. High-energy (>70 keV) x-ray conversion efficiency measurement on the ARC laser at the National Ignition Facility

    Science.gov (United States)

    Chen, Hui; Hermann, M. R.; Kalantar, D. H.; Martinez, D. A.; Di Nicola, P.; Tommasini, R.; Landen, O. L.; Alessi, D.; Bowers, M.; Browning, D.; Brunton, G.; Budge, T.; Crane, J.; Di Nicola, J.-M.; Döppner, T.; Dixit, S.; Erbert, G.; Fishler, B.; Halpin, J.; Hamamoto, M.; Heebner, J.; Hernandez, V. J.; Hohenberger, M.; Homoelle, D.; Honig, J.; Hsing, W.; Izumi, N.; Khan, S.; LaFortune, K.; Lawson, J.; Nagel, S. R.; Negres, R. A.; Novikova, L.; Orth, C.; Pelz, L.; Prantil, M.; Rushford, M.; Shaw, M.; Sherlock, M.; Sigurdsson, R.; Wegner, P.; Widmayer, C.; Williams, G. J.; Williams, W.; Whitman, P.; Yang, S.

    2017-03-01

    The Advanced Radiographic Capability (ARC) laser system at the National Ignition Facility (NIF) is designed to ultimately provide eight beamlets with a pulse duration adjustable from 1 to 30 ps, and energies up to 1.5 kJ per beamlet. Currently, four beamlets have been commissioned. In the first set of 6 commissioning target experiments, the individual beamlets were fired onto gold foil targets with energy up to 1 kJ per beamlet at 20-30 ps pulse length. The x-ray energy distribution and pulse duration were measured, yielding energy conversion efficiencies of 4-9 × 10-4 for x-rays with energies greater than 70 keV. With greater than 3 J of such x-rays, ARC provides a high-precision x-ray backlighting capability for upcoming inertial confinement fusion and high-energy-density physics experiments on NIF.

  10. Design of an ultrahigh-energy-resolution and wide-energy-range soft X-ray beamline.

    Science.gov (United States)

    Xue, L; Reininger, R; Wu, Y-Q; Zou, Y; Xu, Z-M; Shi, Y-B; Dong, J; Ding, H; Sun, J-L; Guo, F-Z; Wang, Y; Tai, R-Z

    2014-01-01

    A new ultrahigh-energy-resolution and wide-energy-range soft X-ray beamline has been designed and is under construction at the Shanghai Synchrotron Radiation Facility. The beamline has two branches: one dedicated to angle-resolved photoemission spectroscopy (ARPES) and the other to photoelectron emission microscopy (PEEM). The two branches share the same plane-grating monochromator, which is equipped with four variable-line-spacing gratings and covers the 20-2000 eV energy range. Two elliptically polarized undulators are employed to provide photons with variable polarization, linear in every inclination and circular. The expected energy resolution is approximately 10 meV at 1000 eV with a flux of more than 3 × 10(10) photons s(-1) at the ARPES sample positions. The refocusing of both branches is based on Kirkpatrick-Baez pairs. The expected spot sizes when using a 10 µm exit slit are 15 µm × 5 µm (horizontal × vertical FWHM) at the ARPES station and 10 µm × 5 µm (horizontal × vertical FWHM) at the PEEM station. The use of plane optical elements upstream of the exit slit, a variable-line-spacing grating and a pre-mirror in the monochromator that allows the influence of the thermal deformation to be eliminated are essential for achieving the ultrahigh-energy resolution.

  11. Experimental and theoretical studies of dual energy subtraction angiography (DESA) performed using laser-based x-ray source

    Science.gov (United States)

    Krol, Andrzej; Kieffer, Jean-Claude; Ichalalene, Zahia; Jiang, Zhiming; Chamberlain, Charles C.; Scalzetti, Ernest M.

    2001-11-01

    Two types of x-ray sources for dual energy subtraction angiography (DESA), laser-based and conventional, were investigated. A Tabletop Terawatt laser was used to create x-ray source with Ba, La, Nd, Gd, and Ce targets. A theoretical model of image quality was developed. A Figure of Merit, FOM equals SNR./(integral dose)1/2, was obtained. Images of an angiographic contrast detail phantom were obtained using laser-driven x-ray source in DESA regime and a standard angiography unit in DSA regime. The log-signals due to Iodine contrast agent in the images were measured and compared with the theoretical model predictions. The integral dose was estimated. We found that the La and Ba lines extracted by a monochromator are optimal for imaging Iodine contrast with laser-based DESA. In this case, SNR exhibits three- to five-fold improvement, as compared to SNR expected for a tube-based DESA system. Consequently, dose utilization, as defined by FOM, improves by factor of two to three, depending on patient thickness and scatter conditions. When only filters are used, SNR and FOM due to laser-based system are comparable to those due to tube-based DESA. In this case, preferable target/filter combination for the laser system is Ba/I and Ce/Nd for the low- and high-beam, respectively.

  12. X-ray optics developments at the APS for the third generation of high-energy synchrotron radiation sources.

    Science.gov (United States)

    Mills, D M

    1997-05-01

    Third-generation hard-X-ray synchrotron radiation sources simultaneously provide both a need and an opportunity for the development of new short-wavelength optical components. The high power and power densities of the insertion-device-produced X-ray beams have forced researchers to consider what may seem like exotic approaches, such as cryogenically cooled silicon and highly perfect diamond crystals, to mitigate thermal distortions in the first optical components. Once the power has been successfully filtered while maintaining the high beam brilliance, additional specialized optical components can be inserted into the monochromatic beam that take advantage of that brilliance. This paper reviews the performance of such optical components that have been designed, fabricated and tested at the Advanced Photon Source, starting with high-heat-load components and followed by examples of several specialized devices, such as an meV resolution (in-line) monochromator, a high-energy X-ray phase retarder and a phase-zone plate with submicrometer focusing capability.

  13. Evaluation of the composition of filters additional of equipment radiological intraoral by energy dispersive x-ray fluorescence (EDXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Franca, Alana Caroline; Torres, Catarina A.M.P.; Rocha, Ana S.S.; Deniak, Valeriy; Lara, Alessandro L.; Paschuk, Sergei A., E-mail: alanacarolinef@gmail.com, E-mail: sergei@utfpr.edu.br [Universidade Tecnologica Federal do Parana (CPGEI/UTFPR), Curitiba, PR (Brazil). Programa de Pos-Graduacao em Engenharia Eletrica e Informatica Industrial; Fernandes, Angela; Westphalen, Fernando Henrique, E-mail: angelafernandes@ufpr.br [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Setor de Ciencias da Saude

    2013-07-01

    The need for high quality standards for radiographic images in order to make a diagnosis assertive, and being the additional filtration required in the intraoral X-ray equipment show the need of evaluating these filters. This study aims to examine the influence of the elemental composition of the filters of X-ray of dental intraoral equipment in the radiographic images quality. The filters analysis were performed by using the energy dispersive X-ray fluorescence method (EDXRF). Ten conventional filters were analysed. In this study, 33 radiographic exposures were performed using films: twenty radiographs in the incisor region and ten in the molar region, three exposures were also made in the same regions with same conditions without using filter. After radiographs development, optical density was measure and all radiographs were submitted to subjective evaluation by dental radiologists. Data obtained were correlated to effects evaluation of the elemental composition of all filters in the quality of the radiographic images. The elements found were: aluminum, cobalt, copper, sulfur, iron, manganese, titanium, zinc, and zirconium. The images obtained were identified in groups: Molars to 0.3 s; Incisors to 0.2 s; Incisors to 0.3 s, and for the group without filters. From the results obtained it was concluded that both unclear radiographs and ideal radiographs were produced by using filters of elementary common. Therefore, conventional filters evaluated were an acceptable option to produce quality images in dental radiology, despite differences in the composition of the alloys. (author)

  14. ART-XC: A Medium-energy X-ray Telescope System for the Spectrum-R-Gamma Mission

    Science.gov (United States)

    Arefiev, V.; Pavlinsky, M.; Lapshov, I.; Thachenko, A.; Sazonov, S.; Revnivtsev, M.; Semena, N.; Buntov,M.; Vikhlinin, A.; Gubarev, M.; hide

    2008-01-01

    The ART-XC instrument is an X-ray grazing-incidence telescope system in an ABRIXAS-type optical configuration optimized for the survey observational mode of the Spectrum-RG astrophysical mission which is scheduled to be launched in 2011. ART-XC has two units, each equipped with four identical X-ray multi-shell mirror modules. The optical axes of the individual mirror modules are not parallel but are separated by several degrees to permit the four modules to share a single CCD focal plane detector, 1/4 of the area each. The 450-micron-thick pnCCD (similar to the adjacent eROSITA telescope detector) will allow detection of X-ray photons up to 15 keV. The field of view of the individual mirror module is about 18 x 18 arcminutes(exp 2) and the sensitivity of the ART-XC system for 4 years of survey will be better than 10(exp -12) erg s(exp -1) cm(exp -2) over the 4-12 keV energy band. This will allow the ART-XC instrument to discover several thousand new AGNs.

  15. Dual-energy x-ray absorptiometry using 2D digital radiography detector: application to bone densitometry

    Science.gov (United States)

    Dinten, Jean-Marc; Robert-Coutant, Christine; Darboux, Michel

    2001-06-01

    Dual Energy X-Rays Absorptiometry (DXA) is commonly used to separate soft tissues and bone contributions in radiographs. This decomposition leads to bone mineral density (BMD) measurement. Most clinical systems use pencil or fan collimated X-Rays beam with mono detectors or linear arrays. On these systems BMD is computed from bi-dimensional (2D) images obtained by scanning. Our objective is to take advantage of the newly available flat panels detectors and to propose a DXA approach without scanning, based on the use of cone beam X-Rays associated with a 2D detector. This approach yields bone densitometry systems with an equal X and Y resolution, a fast acquisition and a reduced risk of patient motion.Scatter in this case becomes an important issue. While scattering is insignificant on collimated systems, its level and geometrical structure may severely alter BMD measurement on cone beam systems. In our presentation an original DXA method taking into account scattering is proposed. This new approach leads to accurate BMD values.In order to evaluate the accuracy of our new approach, a phantom representative of the spine regions tissue composition (bone, fat , muscle) has been designed. The comparison between the expected theoretical and the reconstructed BMD values validates the accuracy of our method. Results on anthropomorphic spine and hip regions are also presented.

  16. Morphometrics of cellular damage in mice testis receiving X-ray and high-energy particle irradiation

    Science.gov (United States)

    Sapp, Walter J.

    1987-01-01

    Murine tests were exposed to single, low doses of either X-ray, helium, or argon radiation. Animals were sacrificed seventy-two hours later. Testes were fixed for transmission electron microscopy (TEM) and sectioned at either 60 nm for TEM observation or at 2 micron for counting using routine light microscope methods. Counts of the total population of surviving spermatogonia, including all type A cells, intermediate, and type B cells, were taken from tubule cross sections identified as Stage 6 and Stage 1 according to spermatogonial configuration. The surviving fraction of spermatogonia as compared to control, S/S sub o, was calculated for each dose. For both ions and X-rays, there was a rapid decline in survival at dose levels of .10 to .15 Gy in Stage 6 tubules. This was followed by a more gradual decrease in population. At higher doses, 0.30 Gy for argon and 0.80 Gy for helium and X-rays, the cell survival rates declined rapidly. Pre-leptotene spermatocytes in Stage 1 tubules exhibited a different survival curve indicating the extreme radio-sensitivity of type B spermatogonia. Data verify that the seminiferous tubules are composed of a heterogeneous population of cells with different radio-sensitivities and that these differences are manifested even at very low doses.

  17. Band gap opening in strongly compressed diamond observed by x-ray energy loss spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Gamboa, E. J. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Fletcher, L. B. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Lee, H. J. [SLAC National Accelerator Lab., Menlo Park, CA (United States); MacDonald, M. J. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Univ. of Michigan, Ann Arbor, MI (United States); Zastrau, U. [High-Energy Density Science Group, Hamburg (Germany); Gauthier, M. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Gericke, D. O. [Univ. of Warwick (United Kingdom); Vorberger, J. [Helmholtz Association of German Research Centres, Dresden (Germany); Granados, E. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Hastings, J. B. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Glenzer, S. H. [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2016-01-25

    The extraordinary mechanical and optical properties of diamond are the basis of numerous technical applications and make diamond anvil cells a premier device to explore the high-pressure behavior of materials. However, at applied pressures above a few hundred GPa, optical probing through the anvils becomes difficult because of the pressure-induced changes of the transmission and the excitation of a strong optical emission. Such features have been interpreted as the onset of a closure of the optical gap in diamond, and can significantly impair spectroscopy of the material inside the cell. In contrast, a comparable widening has been predicted for purely hydrostatic compressions, forming a basis for the presumed pressure stiffening of diamond and resilience to the eventual phase change to BC8. We here present the first experimental evidence of this effect at geo-planetary pressures, exceeding the highest ever reported hydrostatic compression of diamond by more than 200 GPa and any other measurement of the band gap by more than 350 GPa. We here apply laser driven-ablation to create a dynamic, high pressure state in a thin, synthetic diamond foil together with frequency-resolved x-ray scattering as a probe. The frequency shift of the inelastically scattered x-rays encodes the optical properties and, thus, the behavior of the band gap in the sample. Using the ultra-bright x-ray beam from the Linac Coherent Light Source (LCLS), we observe an increasing direct band gap in diamond up to a pressure of 370 GPa. This finding points to the enormous strains in the anvils and the impurities in natural Type Ia diamonds as the source of the observed closure of the optical window. Our results demonstrate that diamond remains an insulating solid to pressures approaching its limit strength.

  18. Energy dispersive X-ray microanalysis, fluoride release, and antimicrobial properties of glass ionomer cements indicated for atraumatic restorative treatment

    Science.gov (United States)

    Saxena, Sudhanshu; Tiwari, Sonia

    2016-01-01

    Aim: The aim of this study was to compare constituents of glass powder, fluoride release, and antimicrobial properties of new atraumatic restorative treatment material with zirconia fillers and conventional glass ionomer cement (GIC) type IX. Materials and Methods: Thisin vitro study comparing Zirconomer and Fuji IX was executed in three parts: (1) energy dispersive X-ray microanalysis of glass powders (2) analysis of fluoride release at 1st, 3rd, 7th, 15th, and 30th day, and (3) antimicrobial activity against Streptococcus mutans, Lactobacillus casei, and Candida albicans at 48 hours. Data was analyzed using unpaired t-test and two way analysis of variance followed by least significant difference post hoc test. A P value of glass powders, mean atomic percentage of oxygen was more than 50%. According to the weight percentage, zirconium in Zirconomer and silica in Fuji IX were the second main elements. Calcium, zinc, and zirconium were observed only in Zirconomer. At all the time intervals, statistically significant higher amount of fluoride release was observed with Zirconomer than Fuji IX. At 48 hours, mean ± standard deviation (SD) of zone of inhibition against Streptococcus mutans was 11.14 ± 0.77 mm and 8.51 ± 0.43 mm for Zirconomer and Fuji IX, respectively. Against Lactobacillus casei, it was 14.06 ± 0.71 mm for Zirconomer and 11.70 ± 0.39 mm for Fuji IX. No antifungal activity was observed against Candida albicans by Zirconomer and Fuji IX. Conclusion: Zirconomer had higher antibacterial activity against Streptococcus mutans and Lactobacillus casei, which may be attributed to its composition and higher fluoride release. However, it failed to show antifungal effect againstCandida albicans. PMID:27583226

  19. A curved crystal spectrometer for energy calibration and spectral characterization of mammographic x-ray sources.

    Science.gov (United States)

    Hudson, L T; Deslattes, R D; Henins, A; Chantler, C T; Kessler, E G; Schweppe, J E

    1996-10-01

    Clinical efficacy of diagnostic radiology for mammographic examinations is critically dependent on source characteristics, detection efficiency, image resolution and applied high voltage. In this report we focus on means for evaluation of source-dependent issues including noninvasive determination of the applied high voltage, and characterization of intrinsic spectral distributions which in turn reflect the effects of added filtration and target and window contamination. It is shown that a particular form of x-ray curved crystal spectrometry with electronic imaging can serve to determine all relevant parameters within the confines of a standard clinical exposure.

  20. Detector solid angle formulas for use in X-ray energy dispersive spectrometry.

    Science.gov (United States)

    Zaluzec, Nestor J

    2009-04-01

    With the advent of silicon drift X-ray detectors, a range of new geometries has become possible in electron optical columns. Because of their compact size, these detectors can potentially achieve high geometrical collection efficiencies; however, using traditional approximations detector solid angle calculations rapidly break down and at times can yield nonphysical values. In this article we present generalized formulas that can be used to calculate the variation in detection solid angle for contemporary Si(Li) as well as new silicon drift configurations.

  1. Energy dependent delay measurements of quasi-periodic oscillations in low-mass X-ray binaries

    Science.gov (United States)

    Wijers, R. A. M. J.; Van Paradijs, J.; Lewin, W. H. G.

    1987-01-01

    Results of Monte Carlo simulations of the Comptonization of photons in a finite spherical Comptonizing cloud are presented. The energy dependence of the arrival times of the Comptonized photons is very different for different input photon spectra. If the delays observed in the high-frequency QPO of Cyg X-2 and GX5-1 are the result of Comptonization, multichannel time-delay measurements may constrain the energy of the input photons and thus provide important information on the accretion process in low-mass X-ray binaries.

  2. Development of a low-noise readout ASIC for Silicon Drift Detectors in high energy resolution X-ray spectrometry

    Science.gov (United States)

    Atkin, E.; Levin, V.; Malankin, E.; Shumikhin, V.

    2017-03-01

    ASIC with a low-noise readout channel for Silicon Drift Detectors in high energy resolution X-ray spectrometry was designed and prototyped in the AMS 350 nm CMOS process via Europractice as a miniASIC. For the analog readout channel tests there was used the detector module SDD-10-130-PTW LTplus-ic (PNDetector GmbH). The measured energy resolution of this module with the designed readout channel: 200 eV (FWHM) at 55Fe, -16 °C, 1 kcps and a peaking time of 8 μs.

  3. Precision X-ray spectroscopy of kaonic atoms as a probe of low-energy kaon-nucleus interaction

    Directory of Open Access Journals (Sweden)

    Shi H.

    2016-01-01

    Full Text Available In the exotic atoms where one atomic 1s electron is replaced by a K−, the strong interaction between the K− and the nucleus introduces an energy shift and broadening of the low-lying kaonic atomic levels which are determined by only the electromagnetic interaction. By performing X-ray spectroscopy for Z = 1,2 kaonic atoms, the SIDDHARTA experiment determined with high precision the shift and width for the 1s state of K− p and the 2p state of kaonic helium-3 and kaonic helium-4. These results provided unique information of the kaon-nucleus interaction in the low energy limit.

  4. Ionization energy shift of characteristic K x-ray lines from high-Z materials for plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Słabkowska, K.; Szymańska, E.; Polasik, M. [Faculty of Chemistry, Nicholas Copernicus University, 87-100 Toruń (Poland); Pereira, N. R. [Ecopulse, Inc., 7844 Vervain Ct, Springfield, Virginia 22152 (United States); Rzadkiewicz, J. [National Centre for Nuclear Research, 05-400 Otwock (Poland); Seely, J. F. [Artep, Inc., 2922 Excelsior Springs Ct, Ellicott, Maryland 21042 (United States); Weber, B. V.; Schumer, J. W. [Naval Research Laboratory, Washington, DC 20375 (United States)

    2014-03-15

    The energy of the characteristic x-rays emitted by high atomic number atoms in a plasma that contains energetic electrons depends on the atom's ionization. For tungsten, the ionization energy shift of the L-lines has recently been used to diagnose the plasma's ionization; the change in energy of a K-line has been measured for iridium and observed for ytterbium. Here, we present detailed computations of the ionization energy shift to K-lines of these and an additional element, dysprosium; for these atoms, some K-lines nearly coincide in energy with K-edges of slightly lower Z atoms so that a change in transmission behind a K-edge filter betrays a change in energy. The ionization energy shift of such high-energy K-lines may enable a unique diagnostic when the plasma is inside an otherwise opaque enclosure such as hohlraums used on the National Ignition Facility.

  5. Joint x-ray

    Science.gov (United States)

    X-ray - joint; Arthrography; Arthrogram ... x-ray technologist will help you position the joint to be x-rayed on the table. Once in place, pictures are taken. The joint may be moved into other positions for more ...

  6. The nuclear spectroscopic telescope array (NuSTAR) high-energy X-ray mission

    DEFF Research Database (Denmark)

    Harrison, Fiona A.; Craig, William W.; Christensen, Finn Erland

    2013-01-01

    of sensitivity and spatial and spectral resolution, NuSTAR will pursue five primary scientific objectives: (1) probe obscured active galactic nucleus (AGN) activity out to the peak epoch of galaxy assembly in the universe (at z ≲ 2) by surveying selected regions of the sky; (2) study the population of hard X......-ray-emitting compact objects in the Galaxy by mapping the central regions of the Milky Way; (3) study the non-thermal radiation in young supernova remnants, both the hard X-ray continuum and the emission from the radioactive element 44Ti; (4) observe blazars contemporaneously with ground-based radio, optical, and Te......V telescopes, as well as with Fermi and Swift , to constrain the structure of AGN jets; and (5) observe line and continuum emission from core-collapse supernovae in the Local Group, and from nearby Type Ia events, to constrain explosion models. During its baseline two-year mission, NuSTAR will also undertake...

  7. Reference standards for body fat measures using GE dual energy x-ray absorptiometry in Caucasian adults.

    Science.gov (United States)

    Imboden, Mary T; Welch, Whitney A; Swartz, Ann M; Montoye, Alexander H K; Finch, Holmes W; Harber, Matthew P; Kaminsky, Leonard A

    2017-01-01

    Dual energy x-ray absorptiometry (DXA) is an established technique for the measurement of body composition. Reference values for these variables, particularly those related to fat mass, are necessary for interpretation and accurate classification of those at risk for obesity-related health complications and in need of lifestyle modifications (diet, physical activity, etc.). Currently, there are no reference values available for GE-Healthcare DXA systems and it is known that whole-body and regional fat mass measures differ by DXA manufacturer. To develop reference values by age and sex for DXA-derived fat mass measurements with GE-Healthcare systems. A de-identified sample of 3,327 participants (2,076 women, 1,251 men) was obtained from Ball State University's Clinical Exercise Physiology Laboratory and University of Wisconsin-Milwaukee's Physical Activity & Health Research Laboratory. All scans were completed using a GE Lunar Prodigy or iDXA and data reported included percent body fat (%BF), fat mass index (FMI), and ratios of android-to-gynoid (A/G), trunk/limb, and trunk/leg fat measurements. Percentiles were calculated and a factorial ANOVA was used to determine differences in the mean values for each variable between age and sex. Normative reference values for fat mass variables from DXA measurements obtained from GE-Healthcare DXA systems are presented as percentiles for both women and men in 10-year age groups. Women had higher (p<0.01) mean %BF and FMI than men, whereas men had higher (p<0.01) mean ratios of A/G, trunk/limb, and trunk/leg fat measurements than women. These reference values provide clinicians and researchers with a resource for interpretation of DXA-derived fat mass measurements specific to use with GE-Healthcare DXA systems.

  8. Validation of fan beam dual energy x ray absorptiometry for body composition assessment in adults aged 18-45 years.

    Science.gov (United States)

    Norcross, J; Van Loan, M D

    2004-08-01

    Pencil beam dual energy x ray absorptiometry (DXA) has been shown to provide valid estimates of body fat (%BF), but DXA fan beam technology has not been adequately tested to determine its validity. To compare %BF estimated from fan beam DXA with %BF determined using two and three compartment (2C, 3C) models. Men (n = 25) and women (n = 31), aged 18-41 years, participated in the study. Body density, from hydrostatic weighing, was used in the 2C estimate of %BF; DXA was used to determine bone mineral content (BMC) for the 3C estimate of %BF calculated using body density and BMC (3C(BMC)). DXA was also used to determine %BF. Analysis of variance was used to test for significant differences in %BF between sexes and among methods. Women were significantly shorter, weighed less, had less fat free mass, and a higher %BF than men. No significant differences were found among methods (2C, 3C(BMC), DXA) for determination of %BF in either sex. Although not significant, Bland-Altman plots showed that DXA gave higher values for %BF than the 2C and 3C(BMC) methods. DXA determination of %BF was not different from that of the 2C and 3C(BMC) models in this group of young adults. However, to validate fan beam DXA fully as a method for body composition assessment in a wide range of individuals and populations, comparisons are needed that use a 4C model with a measure of total body water and BMC.

  9. From EXOSAT to the High Energy Astrophysics Science Archive (HEASARC): X-ray Astronomy Comes of Age

    Science.gov (United States)

    White, Nicholas E.

    2012-01-01

    In May 1983 the European Space Agency launched EXOSAT, its first X-ray astronomy observatory. Even though it lasted only 3 short years, this mission brought not only new capabilities that resulted in unexpected discoveries, but also a pioneering approach to operations and archiving that changed X-ray astronomy from observations led by small instrument teams, to an observatory approach open to the entire community through a guest observer program. The community use of the observatory was supported by a small dedicated team of scientists, the precursor to the data center activities created to support e.g. Chandra and XMM-Newton. The new science capabilities of EX OS AT included a 90 hr highly eccentric high earth orbit that allow unprecedented continuous coverage of sources as well as direct communication with the satellite that allowed real time decisions to respond to unexpected events through targets of opportunity. The advantages of this orbit demonstrated by EXOSAT resulted in Chandra and XMM-Newton selecting similar orbits. The three instruments on board the EXOSAT observatory were complementary, designed to give complete coverage over a wide energy band pass of 0.05-50 keY. An onboard processor could be programmed to give multiple data modes that could be optimized in response to science discoveries: These new capabilities resulted in many new discoveries including the first comprehensive study of AGN variability, new orbital periods in X-ray binaries and cataclysmic variables, new black holes, quasi-periodic oscillations from neutron stars and black holes and broad band X-ray spectroscopy. The EXOSAT team generated a well-organized database accessible worldwide over the nascent internet, allowing remote selection of data products, making samples and undertaking surveys from the data. The HEASARC was established by NASA at Goddard Space Flight Center in 1990 as the repository of NASA X-ray and Gamma-ray data. The proven EXOSAT database system became the core

  10. From EXOSAT to the High Energy Astrophysics Science Archive (HEASARC): X-ray Astronomy Comes of Age

    Science.gov (United States)

    White, Nicholas E.

    2013-01-01

    In May 1983 the European Space Agency launched EXOSAT, its first X-ray astronomy observatory. Even though it lasted only 3 short years, this mission brought not only new capabilities that resulted in unexpected discoveries, but also a pioneering approach to operations and archiving that changed X-ray astronomy from observations led by small instrument teams, to an observatory approach open to the entire community through a guest observer program. The community use of the observatory was supported by a small dedicated team of scientists, the precursor to the data center activities created to support e.g. Chandra and XMM-Newton. The new science capabilities of EXOSAT included a 90 hr highly eccentric high earth orbit that allow unprecedented continuous coverage of sources as well as direct communication with the satellite that allowed real time decisions to respond to unexpected events through targets of opportunity. The advantages of this orbit demonstrated by EXOSAT resulted in Chandra and XMM-Newton selecting similar orbits. The three instruments on board the EXOSAT observatory were complementary, designed to give complete coverage over a wide energy band pass of 0.05-50 keV. An onboard processor could be programed to give multiple data modes that could be optimized in response to science discoveries. These new capabilities resulted in many new discoveries including the first comprehensive study of AGN variability, new orbital periods in X-ray binaries and cataclysmic variables, new black holes, quasi-periodic oscillations from neutron stars and black holes and broad band X-ray spectroscopy. The EXOSAT team generated a well-organized database accessible worldwide over the nascent internet, allowing remote selection of data products, making samples and undertaking surveys from the data. The HEASARC was established by NASA at Goddard Space Flight Center in 1990 as the repository of NASA X-ray and Gamma-ray data. The proven EXOSAT database system became the core of

  11. Study of soil aggregate breakdown dynamics under low dispersive ultrasonic energies with sedimentation and X-ray attenuation.

    Science.gov (United States)

    Schomakers, Jasmin; Zehetner, Franz; Mentler, Axel; Ottner, Franz; Mayer, Herwig

    2015-10-01

    It has been increasingly recognized that soil organic matter stabilization is strongly controlled by physical binding within soil aggregates. It is therefore essential to measure soil aggregate stability reliably over a wide range of disruptive energies and different aggregate sizes. To this end, we tested high-accuracy ultrasonic dispersion in combination with subsequent sedimentation and X-ray attenuation. Three arable topsoils (notillage) from Central Europe were subjected to ultrasound at four different specific energy levels: 0.5, 6.7, 100 and 500 J cm-3, and the resulting suspensions were analyzed for aggregate size distribution by wet sieving (2 000-63 μm) and sedimentation/X-ray attenuation (63-2 μm). The combination of wet sieving and sedimentation technique allowed for a continuous analysis, at high resolution, of soil aggregate breakdown dynamics after defined energy inputs. Our results show that aggregate size distribution strongly varied with sonication energy input and soil type. The strongest effects were observed in the range of low specific energies (aggregate stability and release of soil organic matter upon aggregate breakdown.

  12. Spur energy distributions in liquid water using a generalized oscillator strength from inelastic X-ray scattering measurements

    Science.gov (United States)

    Karamitros, Mathieu; Mozumder, Asokendu

    2017-12-01

    The present paper utilizes the currently most accurate and complete generalized oscillator strength (GOS), determined experimentally using synchrotron X-rays, in constructing the spur energy distribution in liquid water. This replaces the earlier approximate evaluation using UV reflection and requiring long and uncertain extrapolation. Normalized distribution is provided as histograms of 5 eV bins up to 100 eV of energy loss for different incident electron energies. Certain other related quantities are also computed. These include the effective number of electrons receiving energy transfer, mean excitation potential and its effective value as a function of incident electron energy. This paper gives the results for first collision that is for the differential track, which is close to the integrated track result for high incident energy, as shown in some earlier calculations. On the whole, some earlier computations, but not all are approximately verified.

  13. Monte Carlo simulation of the X-ray response of a germanium microstrip detector with energy and position resolution

    CERN Document Server

    Rossi, G; Fajardo, P; Morse, J

    1999-01-01

    We present Monte Carlo computer simulations of the X-ray response of a micro-strip germanium detector over the energy range 30-100 keV. The detector consists of a linear array of lithographically defined 150 mu m wide strips on a high purity monolithic germanium crystal of 6 mm thickness. The simulation code is divided into two parts. We first consider a 10 mu m wide X-ray beam striking the detector surface at normal incidence and compute the interaction processes possible for each photon. Photon scattering and absorption inside the detector crystal are simulated using the EGS4 code with the LSCAT extension for low energies. A history of events is created of the deposited energies which is read by the second part of the code which computes the energy histogram for each detector strip. Appropriate algorithms are introduced to account for lateral charge spreading occurring during charge carrier drift to the detector surface, and Fano and preamplifier electronic noise contributions. Computed spectra for differen...

  14. In situ multi-element analyses by energy-dispersive X-ray fluorescence on varnishes of historical violins

    Energy Technology Data Exchange (ETDEWEB)

    Echard, Jean-Philippe [Laboratoire de recherche et de restauration, Musee de la musique, Cite de la musique, 221, avenue Jean-Jaures, 75019 Paris (France)]. E-mail: jpechard@cite-musique.fr

    2004-10-08

    Varnishes of Italian violins and other historical stringed instruments have been analyzed by energy-dispersive X-ray fluorescence (EDXRF). The instruments whose varnishes were to be analyzed were chosen from the collection kept in Musee de la Musique in Paris. Direct analyses were performed on instrument varnishes, without any sampling and non-destructively, showing inorganic elements such as lead, mercury and iron that could be related to siccatives or pigments. Analytical results and their comparison with old formulae or traditional recipes of violin varnishes, as with the few previous analytical results, will be discussed.

  15. In-situ study of the growth of CuO nanowires by energy dispersive X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, Himanshu; Ganguli, Tapas; Deb, S. K. [Indus Synchrotrons Utilization Division, Raja Ramanna Centre for Advanced technology, Indore-452013 (India); Sant, Tushar; Poswal, Himanshu; Sharma, S. M. [High Pressure and Synchrotron Physics Division, Bhabha Atomic Research Centre, Mumbai (India)

    2013-02-05

    Growth of CuO nanowires by annealing method has been studied in-situ by grazing incidence Energy Dispersive X-ray Diffraction (EDXRD) technique on Indus-2. It was observed that Cu slowly oxidized to Cu{sub 2}O and finally to CuO. The data was taken as a function of time at two annealing temperatures 500 Degree-Sign C where nanowires form and 300 Degree-Sign C where nanowires don't form. We found that the strain in the CuO layer may be a principal factor for the spontaneous growth of nanowires in annealing method.

  16. An Energy Dispersive X-ray Spectroscopy Analysis of Elemental Changes of a Persimmon Phytobezoar Dissolved in Coca-Cola.

    Science.gov (United States)

    Iwamuro, Masaya; Urata, Haruo; Higashi, Reiji; Nakagawa, Masahiro; Ishikawa, Shin; Shiraha, Hidenori; Okada, Hiroyuki

    To investigate the mechanism of phytobezoar dissolution by Coca-Cola(®), persimmon phytobezoar pieces removed from a 60-year-old Japanese woman were analyzed by energy dispersive X-ray spectroscopy. The amount of calcium significantly decreased after dissolution treatment using Coca-Cola(®), suggesting a potential contribution of calcium to dissolution mechanisms. Moreover, immersion in Coca-Cola(®) for 120 hours on the exterior surface revealed that Coca-Cola(®) did not permeate persimmon phytobezoars. This is the first study to investigate the mechanisms of persimmon phytobezoar permeability and dissolution induced by Coca-Cola(®).

  17. Dose-rate controlled energy dispersive x-ray spectroscopic mapping of the metallic components in a biohybrid nanosystem

    Science.gov (United States)

    Zhu, Yuanyuan; Munro, Catherine J.; Olszta, Matthew J.; Edwards, Danny J.; Braunschweig, Adam B.; Knecht, Marc R.; Browning, Nigel D.

    2016-08-01

    In this work, we showcase that through precise control of the electron dose rate, state-of-the-art large solid angle energy dispersive x-ray spectroscopy mapping in aberration-corrected scanning transmission electron microscope is capable of faithful and unambiguous chemical characterization of the Pt and Pd distribution in a peptide-mediated nanosystem. This low-dose-rate recording scheme adds another dimension of flexibility to the design of elemental mapping experiments, and holds significant potential for extending its application to a wide variety of beam sensitive hybrid nanostructures.

  18. Dose-rate controlled energy dispersive x-ray spectroscopic mapping of the metallic components in a biohybrid nanosystem

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Yuanyuan; Munro, Catherine J.; Olszta, Matthew J.; Edwards, Danny J.; Braunschweig, Adam B.; Knecht, Marc R.; Browning, Nigel D.

    2016-06-30

    In this work, we showcase that through precise control of the electron dose rate, state-of-the-art large solid angle energy dispersive X-ray spectroscopy (EDS) mapping in aberration-corrected scanning transmission electron microscope (STEM) is capable of faithful and unambiguous chemical characterization of the Pt and Pd distribution in a peptide-mediated nanosystem. This low-dose-rate recording scheme adds another dimension of flexibility to the design of elemental mapping experiments, and holds significant potential for extending its application to a wide variety of beam sensitive hybrid nanostructures.

  19. Energy Dispersive X-Ray Fluorescent Analysis of Soil in the Vicinity of Industrial Areas and Heavy Metal Pollution Assessment

    Science.gov (United States)

    Singh, V.; Joshi, G. C.; Bisht, D.

    2017-05-01

    The soil of two agricultural sites near an industrial area was investigated for heavy metal pollution using energy dispersive X-ray fluorescence (EDXRF). The concentration values for 17 elements were determined in the soil samples including eight heavy metal elements, i.e., Fe, Ni, As, Pb, Mn, Cr, Cu, and Zn. The soil near a pulp and paper mill was found to be highly polluted by the heavy metals. The concentration data obtained by EDXRF were further examined by calculating the pollution index and Nemerow integrated pollution index.

  20. Detection of metallic elements from paraffin-embedded tissue blocks by energy dispersive X-ray fluorescence spectrometry.

    Science.gov (United States)

    Takahashi, Motonori; Kinoshita, Hiroshi; Nishiguchi, Minori; Nishio, Hajime

    2010-03-01

    Energy dispersive X-ray fluorescence spectrometry (EDX) enables rapid, non-destructive, multi-elemental analysis. Using EDX, lead and some other metallic elements were detected in paraffin-blocks in which skin samples from a gunshot wound were embedded. Lead was not identified in control samples from non-injured cases. These findings indicate that EDX is a useful method for rapid non-destructive analysis of paraffin-embedded blocks. This technique can provide scientific evidence for identification of a firearm even after storing the sample for a long time. (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  1. Study of unfolding methods for X-ray spectra obtained with CDTE detectors in the mammography energy range

    Energy Technology Data Exchange (ETDEWEB)

    Querol, A.; Gallardo, S.; Rodenas, J.; Verdu, G.; Barrachina, T. [Departamento de Ingenieria Quimica y Nuclear, Universidad Politecnica de Valencia, Cami de Vera, s/n 46022 Valencia (Spain)

    2010-07-01

    Quality control parameters for an X-ray tube strongly depend on the accurate knowledge of the primary spectrum, but it is difficult to obtain it experimentally by direct measurements. Indirect spectrometry techniques such as Compton scattering can be used in X-ray spectrum assessment avoiding the pile-up effect in detectors. However, an unfolding method is required for this kind of measurements. In previous works, a methodology to assess primary X-ray spectra in the diagnostic energy range by means of the Compton scattering technique has been analysed. This methodology included a Monte Carlo simulation model, using the MCNP5 code, of the actual experimental set-up providing a Pulse Height Distribution (PHD) for a given primary spectrum. It reproduced the interaction of photons and electrons with the Compton spectrometer and with a High Purity Germanium detector. In this work, a CdTe detector is proposed instead of the HP Germanium. CdTe detector does not require a liquid nitrogen cooling system, but its resolution is poor for the same energy range and its efficiency comes down for energies greater than 55 keV being 70% at 90 keV. In despite of these disadvantages, CdTe detector has been considered due to its low cost and easy handling and portability. The model can provide a PHD and a Response Matrix, for different X-ray spectra, taken from the IPEM 78 catalogue. The primary spectrum can be estimated applying the MTSVD (Modified Truncated Singular Value Decomposition) and the Tikhonov unfolding method. Both unfolding methods cause some loss of information on the reconstructed primary spectra. In this paper, a comparison of the ability to obtain primary spectra using both MTSVD and Tikhonov unfolding methods has been done. As well a sensitivity analysis in order to test the proposed unfolding methods when they are applied to PHDs obtained with the MCNP model has been developed. A variation on parameters such as target materials and voltages over the mammography

  2. Single-shot full strain tensor determination with microbeam X-ray Laue diffraction and a two-dimensional energy-dispersive detector.

    Science.gov (United States)

    Abboud, A; Kirchlechner, C; Keckes, J; Conka Nurdan, T; Send, S; Micha, J S; Ulrich, O; Hartmann, R; Strüder, L; Pietsch, U

    2017-06-01

    The full strain and stress tensor determination in a triaxially stressed single crystal using X-ray diffraction requires a series of lattice spacing measurements at different crystal orientations. This can be achieved using a tunable X-ray source. This article reports on a novel experimental procedure for single-shot full strain tensor determination using polychromatic synchrotron radiation with an energy range from 5 to 23 keV. Microbeam X-ray Laue diffraction patterns were collected from a copper micro-bending beam along the central axis (centroid of the cross section). Taking advantage of a two-dimensional energy-dispersive X-ray detector (pnCCD), the position and energy of the collected Laue spots were measured for multiple positions on the sample, allowing the measurement of variations in the local microstructure. At the same time, both the deviatoric and hydrostatic components of the elastic strain and stress tensors were calculated.

  3. Low-energy Galactic centre gamma-rays from low-mass X-ray binaries

    Science.gov (United States)

    Kluzniak, W.; Ruderman, M.; Shaham, J.; Tavani, M.

    1988-01-01

    Nonthermal processes in low-mass X-ray binaries concentrated in the Galactic bulge are proposed as the direct source of the three continuum components of the emission from the Galactic center region (GCR) and also, possibly, as the indirect source of the 511-keV electron-positron annihilation line. It is suggested that the softer power-law component of the GCR continuum arises from synchrotron emission of relativistic electrons in the strongly nonuniform magnetic field of the neutron star and, more tentatively, that the MeV bump is the result of interaction of harder gamma rays with power-law photons. The hardest power law may be due to Compton scattering of relativistic electrons or photons.

  4. Understanding transport phenomena in electrochemical energy devices via X-ray nano CT

    Science.gov (United States)

    Tjaden, B.; Lane, J.; Brett, D. J. L.; Shearing, P. R.

    2017-06-01

    Porous support layers in electrochemical devices ensure mechanical stability of membrane assemblies such as solid oxide fuel cells and oxygen transport membranes (OTMs). At the same time, porous layers affect diffusive mass transport of gaseous reactants and contribute to performance losses at high fuel utilisation and conversion ratios. Microstructural characteristics are vital to calculate mass transport phenomena, where tortuosity remains notoriously difficult to determine. Here, the tortuosity of tubular porous support layers of OTMs is evaluated via high resolution X-ray nano computed tomography. The high resolution reveals the complex microstructure of the samples to then execute a selection of image-based tortuosity calculation algorithms. Visible differences between geometric and flux-based algorithms are observed and have thus to be applied with caution.

  5. Effective X-ray beam size measurements of an X-ray tube and polycapillary X-ray lens system using a scanning X-ray fluorescence method

    Energy Technology Data Exchange (ETDEWEB)

    Gherase, Mihai R., E-mail: mgherase@csufresno.edu; Vargas, Andres Felipe

    2017-03-15

    Size measurements of an X-ray beam produced by an integrated polycapillary X-ray lens (PXL) and X-ray tube system were performed by means of a scanning X-ray fluorescence (SXRF) method using three different metallic wires. The beam size was obtained by fitting the SXRF data with the analytical convolution between a Gaussian and a constant functions. For each chemical element in the wire an effective energy was calculated based on the incident X-ray spectrum and its photoelectric cross section. The proposed method can be used to measure the effective X-ray beam size in XRF microscopy studies.

  6. A simple X-ray emitter.

    Science.gov (United States)

    Murakami, Hiroaki; Ono, Ryoichi; Hirai, Atsuhiko; Hosokawa, Yoshinori; Kawai, Jun

    2005-07-01

    A compact X-ray emission instrument is made, and the X-ray spectra are measured by changing the applied electric potential. Strong soft X-rays are observed when evacuating roughly and applying a high voltage to an insulator settled in this device. The X-ray intensity is higher as the applied voltage is increased. A light-emitting phenomenon is observed when this device emits X-rays. The present X-ray emitter is made of a small cylinder with a radius of 20 mm and a height of 50 mm. This X-ray generator has a potential to be used as an X-ray source in an X-ray fluorescence spectrometer.

  7. Precision Error in Dual-Energy X-Ray Absorptiometry Body Composition Measurements in Elite Male Rugby League Players.

    Science.gov (United States)

    Barlow, Matthew J; Oldroyd, Brian; Smith, Debbie; Lees, Matthew J; Brightmore, Amy; Till, Kevin; Jones, Benjamin; Hind, Karen

    2015-01-01

    Body composition analysis using dual-energy X-ray absorptiometry (DXA) is becoming increasingly popular in both clinical and sports science settings. Obesity, characterized by high fat mass (FM), is associated with larger precision errors; however, precision error for athletic groups with high levels of lean mass (LM) are unclear. Total (TB) and regional (limbs and trunk) body composition were determined from 2 consecutive total body scans (GE Lunar iDXA) with re-positioning in 45 elite male rugby league players (age: 21.8 ± 5.4 yr; body mass index: 27.8 ± 2.5 kg m(-1)). The root mean squared standard deviation (percentage co-efficient of variation) were TB bone mineral content: 24g (1.7%), TB LM: 321 g (1.6%), and TB FM: 280 g (2.3%). Regional precision values were superior for measurements of bone mineral content: 4.7-16.3 g (1.7-2.1%) and LM: 137-402 g (2.0-2.4%), than for FM: 63-299 g (3.1-4.1%). Precision error of DXA body composition measurements in elite male rugby players is higher than those reported elsewhere for normal adult populations and similar to those reported in those who are obese. It is advised that caution is applied when interpreting longitudinal DXA-derived body composition measurements in male rugby players and population-specific least significant change should be adopted. Copyright © 2015 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  8. Reproducibility of trabecular bone score with different scan modes using dual-energy X-ray absorptiometry: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Bandirali, Michele; Messina, Carmelo [Universita degli Studi di Milano, Scuola di Specializzazione in Radiodiagnostica, Milano (Italy); Di Leo, Giovanni [Unita di Radiologia, IRCCS Policlinico San Donato, San Donato Milanese (Italy); Pastor Lopez, Maria Juana; Ulivieri, Fabio M. [Servizio di Medicina Nucleare, Ospedale Maggiore, Mineralometria Ossea Computerizzata e Ambulatorio Malattie Metabolismo Minerale e Osseo, Milano (Italy); Mai, Alessandro [Universita degli Studi di Milano, Tecniche di Radiologia Medica, per Immagini e Radioterapia, Milano (Italy); Sardanelli, Francesco [Unita di Radiologia, IRCCS Policlinico San Donato, San Donato Milanese (Italy); Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, San Donato Milanese (Italy)

    2014-08-12

    The trabecular bone score (TBS) accounts for the bone microarchitecture and is calculated on dual-energy X-ray absorptiometry (DXA). We estimated the reproducibility of the TBS using different scan modes compared to the reproducibility bone mineral density (BMD). A spine phantom was used with a Hologic QDR-Discovery A densitometer. For each scan mode [fast array, array, high definition (HD)], 25 scans were automatically performed without phantom repositioning; a further 25 scans were performed with phantom repositioning. For each scan, the TBS was obtained. The coefficient of variation (CoV) was calculated as the ratio between standard deviation and mean; percent least significant change (LSC%) as 2.8 x CoV; reproducibility as the complement to 100 % of LSC%. Differences among scan modes were assessed using ANOVA. Without phantom repositioning, the mean TBS (mm{sup -1}) was: 1.352 (fast array), 1.321 (array), and 1.360 (HD); with phantom repositioning, it was 1.345, 1.332, and 1.362, respectively. Reproducibility of the TBS without phantom repositioning was 97.7 % (fast array), 98.3 % (array), and 98.2 % (HD); with phantom repositioning, it was 97.9 %, 98.7 %, and 98.4 %, respectively. LSC% was ≤2.26 %. Differences among scan modes were all statistically significant (p ≤ 0.019). Reproducibility of BMD was 99.1 % with all scan modes, while LSC% was from 0.86 % to 0.91 %. Reproducibility error of the TBS was 2-3-fold higher than that of BMD. Although statistically significant, differences in TBS among scan modes were within the highest LSC%. Thus, the three scan modes can be considered interchangeable. (orig.)

  9. Benchmarking transition energies and emission strengths for X-ray astrophysics with measurements at the Livermore EBITs

    Energy Technology Data Exchange (ETDEWEB)

    Hell, Natalie [Friedrich Alexander Univ., Erlangen (Germany)

    2017-03-15

    K-shell transitions in astrophysically abundant metals and L-shell transitions in Fe group elements show characteristic signatures in the soft X-ray spectrum in the energy range 0.1–10 keV. These signatures have great diagnostic value for plasma parameters such as electron and ion temperatures and densities, and can thus help understand the physics controlling the energetic processes in astrophysical sources. This diagnostic power increases with advances in spectral resolution and effective area of the employed X-ray observatories. However, to make optimal use of the diagnostic potential – whether through global spectral modeling or through diagnostics from local modeling of individual lines – the underlying atomic physics has to be complete and well known. With the next generation of soft X-ray observatories featuring micro-calorimeters such as the SXS on Astro- H/Hitomi and the X-IFU on Athena, broadband high-resolution spectroscopy with large effective area will become more commonly available in the next decade. With these spectrometers, the accuracy of the plasma parameters derived from spectral modeling will be limited by the uncertainty of the reference atomic data rather than by instrumental factors, as is sometimes already the case for the high-resolution grating observations with Chandra-HETG and XMM-Newton-RGS. To take full advantage of the measured spectra, assessment of the accuracy of and improvements to the available atomic reference data are therefore important. Dedicated measurements in the laboratory are essential to benchmark the theoretical calculations providing the bulk of the reference data used in astrophysics. Experiments at the Lawrence Livermore National Laboratory electron beam ion traps (EBIT-I and SuperEBIT) have a long history of providing this service. In this work, I present new measurements of transition energies and absolute electron impact excitation cross sections geared towards currently open atomic physics data needs.

  10. A Next-Generation Hard X-Ray Nanoprobe Beamline for In Situ Studies of Energy Materials and Devices

    Energy Technology Data Exchange (ETDEWEB)

    Maser, Jong [Argonne National Lab. (ANL), Argonne, IL (United States); Lai, Barry [Argonne National Lab. (ANL), Argonne, IL (United States); Buonassisi, Toni [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Cai, Zhonghou [Argonne National Lab. (ANL), Argonne, IL (United States); Chen, Si [Argonne National Lab. (ANL), Argonne, IL (United States); Finney, Lydia [Argonne National Lab. (ANL), Argonne, IL (United States); Gleber, Sophie-Charlotte [Argonne National Lab. (ANL), Argonne, IL (United States); Jacobsen, Chris [Argonne National Lab. (ANL), Argonne, IL (United States); Preissner, Curt [Argonne National Lab. (ANL), Argonne, IL (United States); Roehrig, Chris [Argonne National Lab. (ANL), Argonne, IL (United States); Rose, Volker [Argonne National Lab. (ANL), Argonne, IL (United States); Shu, Deming [Argonne National Lab. (ANL), Argonne, IL (United States); Vine, David [Argonne National Lab. (ANL), Argonne, IL (United States); Vogt, Stefan [Argonne National Lab. (ANL), Argonne, IL (United States)

    2013-08-20

    The Advanced Photon Source is developing a suite of new X-ray beamlines to study materials and devices across many length scales and under real conditions. One of the flagship beamlines of the APS upgrade is the In Situ Nanoprobe (ISN) beamline, which will provide in situ and operando characterization of advanced energy materials and devices under varying temperatures, gas ambients, and applied fields, at previously unavailable spatial resolution and throughput. Examples of materials systems include inorganic and organic photovoltaic systems, advanced battery systems, fuel cell components, nanoelectronic devices, advanced building materials and other scientifically and technologically relevant systems. To characterize these systems at very high spatial resolution and trace sensitivity, the ISN will use both nanofocusing mirrors and diffractive optics to achieve spots sizes as small as 20 nm. Nanofocusing mirrors in Kirkpatrick–Baez geometry will provide several orders of magnitude increase in photon flux at a spatial resolution of 50 nm. Diffractive optics such as zone plates and/or multilayer Laue lenses will provide a highest spatial resolution of 20 nm. Coherent diffraction methods will be used to study even small specimen features with sub-10 nm relevant length scale. A high-throughput data acquisition system will be employed to significantly increase operations efficiency and usability of the instrument. The ISN will provide full spectroscopy capabilities to study the chemical state of most materials in the periodic table, and enable X-ray fluorescence tomography. In situ electrical characterization will enable operando studies of energy and electronic devices such as photovoltaic systems and batteries. We also describe the optical concept for the ISN beamline, the technical design, and the approach for enabling a broad variety of in situ studies. Furthermore, we discuss the application of hard X-ray microscopy to study defects in multi-crystalline solar

  11. Phase transitions in shock compressed bismuth identified using single photon energy dispersive X-ray diffraction (SPEDX)

    Science.gov (United States)

    Briggs, R.; Suggit, MJ; Gorman, MG; Coleman, A.; Heathcote, R.; Higginbotham, A.; Patel, S.; Wark, JS; McMahon, MI

    2017-10-01

    We present evidence for phase transitions in shock-compressed bismuth using the SPEDX x-ray diffraction technique. Experiments were performed on the Vulcan laser at the Central Laser Facility, RAL, Didcot, UK. We observed diffraction from the (110) bcc peak of Bi-V, and from its calculated lattice parameter the pressure was determined to be approximately 17 GPa. Upon further compression (higher laser intensities), no further diffraction from solid phases was observed. Shock melting of bismuth is thought to occur between 18 and 27 GPa. Diffraction results at lower pressures as a function of delay time are also presented.

  12. High-Energy Resolution Fluorescence Detected X-Ray Absorption Spectroscopy: A Powerful New Structural Tool in Environmental Biogeochemistry Sciences.

    Science.gov (United States)

    Proux, Olivier; Lahera, Eric; Del Net, William; Kieffer, Isabelle; Rovezzi, Mauro; Testemale, Denis; Irar, Mohammed; Thomas, Sara; Aguilar-Tapia, Antonio; Bazarkina, Elena F; Prat, Alain; Tella, Marie; Auffan, Mélanie; Rose, Jérôme; Hazemann, Jean-Louis

    2017-11-01

    The study of the speciation of highly diluted elements by X-ray absorption spectroscopy (XAS) is extremely challenging, especially in environmental biogeochemistry sciences. Here we present an innovative synchrotron spectroscopy technique: high-energy resolution fluorescence detected XAS (HERFD-XAS). With this approach, measurement of the XAS signal in fluorescence mode using a crystal analyzer spectrometer with a ∼1-eV energy resolution helps to overcome restrictions on sample concentrations that can be typically measured with a solid-state detector. We briefly describe the method, from both an instrumental and spectroscopic point of view, and emphasize the effects of energy resolution on the XAS measurements. We then illustrate the positive impact of this technique in terms of detection limit with two examples dealing with Ce in ecologically relevant organisms and with Hg species in natural environments. The sharp and well-marked features of the HERFD-X-ray absorption near-edge structure spectra obtained enable us to determine unambiguously and with greater precision the speciation of the probed elements. This is a major technological advance, with strong benefits for the study of highly diluted elements using XAS. It also opens new possibilities to explore the speciation of a target chemical element at natural concentration levels, which is critical in the fields of environmental and biogeochemistry sciences. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  13. Toward Control of Matter: Basic Energy Science Needs for a New Class of X-Ray Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Arenholz, Elke; Belkacem, Ali; Cocke, Lew; Corlett, John; Falcone, Roger; Fischer, Peter; Fleming, Graham; Gessner, Oliver; Hasan, M. Zahid; Hussain, Zahid; Kevan, Steve; Kirz, Janos; McCurdy, Bill; Nelson, Keith; Neumark, Dan; Nilsson, Anders; Siegmann, Hans; Stocks, Malcolm; Schafer, Ken; Schoenlein, Robert; Spence, John; Weber, Thorsten

    2008-09-24

    Over the past quarter century, light-source user facilities have transformed research in areas ranging from gas-phase chemical dynamics to materials characterization. The ever-improving capabilities of these facilities have revolutionized our ability to study the electronic structure and dynamics of atoms, molecules, and even the most complex new materials, to understand catalytic reactions, to visualize magnetic domains, and to solve protein structures. Yet these outstanding facilities still have limitations well understood by their thousands of users. Accordingly, over the past several years, many proposals and conceptual designs for"next-generation" x-ray light sources have been developed around the world. In order to survey the scientific problems that might be addressed specifically by those new light sources operating below a photon energy of about 3 keV and to identify the scientific requirements that should drive the design of such facilities, a workshop"Science for a New Class of Soft X-Ray Light Sources" was held in Berkeley in October 2007. From an analysisof the most compelling scientific questions that could be identified and the experimental requirements for answering them, we set out to define, without regard to the specific technologies upon which they might be based, the capabilities such light sources would have to deliver in order to dramatically advance the state of research in the areas represented in the programs of the Department of Energy's Office of Basic Energy Sciences (BES). This report is based on the workshop presentations and discussions.

  14. Component analyses of urinary nanocrystallites of uric acid stone formers by combination of high-resolution transmission electron microscopy, fast Fourier transformation, energy dispersive X-ray spectroscopy, X-ray diffraction and Fourier transform infrared spectroscopy.

    Science.gov (United States)

    Sun, Xin-Yuan; Xue, Jun-Fa; Xia, Zhi-Yue; Ouyang, Jian-Ming

    2015-06-01

    This study aimed to analyse the components of nanocrystallites in urines of patients with uric acid (UA) stones. X-ray diffraction (XRD), Fourier transform infrared spectroscopy, high-resolution transmission electron microscopy (HRTEM), fast Fourier transformation (FFT) of HRTEM, and energy dispersive X-ray spectroscopy (EDS) were performed to analyse the components of these nanocrystallites. XRD and FFT showed that the main component of urinary nanocrystallites was UA, which contains a small amount of calcium oxalate monohydrate and phosphates. EDS showed the characteristic absorption peaks of C, O, Ca and P. The formation of UA stones was closely related to a large number of UA nanocrystallites in urine. A combination of HRTEM, FFT, EDS and XRD analyses could be performed accurately to analyse the components of urinary nanocrystallites.

  15. ROSI and GEANT4 – A comparison in the context of high energy X-ray physics

    Energy Technology Data Exchange (ETDEWEB)

    Kiunke, Markus [Chair of X-ray Microscopy, University Würzburg, Josef-Martin-Weg 63, 97074 Würzburg (Germany); Stritt, Carina, E-mail: Carina.Stritt@empa.ch [Empa, Swiss Federal Laboratories for Material Science and Technology, Reliability Science and Technology, Überlandstrasse 129, 8600 Dübendorf (Switzerland); Schielein, Richard [Chair of X-ray Microscopy, University Würzburg, Josef-Martin-Weg 63, 97074 Würzburg (Germany); Sukowski, Frank; Hölzing, Astrid [Fraunhofer Development Center for X-ray Technology EZRT, Flugplatzstr. 75, 90768 Fürth (Germany); Zabler, Simon [Chair of X-ray Microscopy, University Würzburg, Josef-Martin-Weg 63, 97074 Würzburg (Germany); Fraunhofer Development Center for X-ray Technology EZRT, Flugplatzstr. 75, 90768 Fürth (Germany); Hofmann, Jürgen; Flisch, Alexander [Empa, Swiss Federal Laboratories for Material Science and Technology, Center for X-ray Analytics, Überlandstrasse 129, 8600 Dübendorf (Switzerland); Kasperl, Stefan [Fraunhofer Development Center for X-ray Technology EZRT, Flugplatzstr. 75, 90768 Fürth (Germany); Sennhauser, Urs [Empa, Swiss Federal Laboratories for Material Science and Technology, Reliability Science and Technology, Überlandstrasse 129, 8600 Dübendorf (Switzerland); and others

    2016-06-15

    This work compares two popular MC simulation frameworks ROSI (Roentgen Simulation) and GEANT4 (Geometry and Tracking in its fourth version) in the context of X-ray physics. The comparison will be performed with the help of a parameter study considering energy, material and length variations. While the total deposited energy as well as the contribution of Compton scattering show a good accordance between all simulated configurations, all other physical effects exhibit large deviations in a comparison of data-sets. These discrepancies between simulations are shown to originate from the different cross sectional databases used in the frameworks, whereas the overall simulation mechanics seem to not have an influence on the agreement of the simulations. A scan over energy, length and material shows that the two parameters energy and material have a significant influence on the agreement of the simulation results, while the length parameter shows no noticeable influence on the deviations between the data-sets.

  16. Body Fat Percentages by Dual-energy X-ray Absorptiometry Corresponding to Body Mass Index Cutoffs for Overweight and Obesity in Indian Children

    Directory of Open Access Journals (Sweden)

    Deepa Pandit

    2009-01-01

    Full Text Available Background Indians are suspected to have higher body fat percent at a given body mass index (BMI than their western counterparts. Objective To estimate percent body fat in apparently healthy Indian children and adolescents by dual-energy X-ray absorptiometry (DXA and explore linkages of BMI with body fat percent for better health risk assessment. Methods Age, weight, height of 316 boys and 250 girls (6–17 years were recorded. Body composition was measured by dual-energy X-ray absorptiometry (DXA. High adiposity was defined as body fat percent (BF% > McCarthy's 85th percentile of body fat reference data. Receiver operating characteristic analysis (ROC was carried out for CDC BMI Z score for it's ability to judge excess fatness. Results High BF% was seen in 38.5% boys and 54.0% girls (p < 0.05. Percentage of obese children as defined by the BMI cutoffs of International Obesity Task Force (IOTF (2.1% for boys and 6.9% for girls was lower than that using Indian (13.7% for boys and 20.9% for girls and CDC (14.1% for boys and 20.9% for girls cutoffs. The point closest to one on the ROC curves of CDC BMI Z-scores indicated high adiposity at BMI cutoff of 22 at the age of 17 yr in both the genders. Conclusions Higher body fat percentage is associated with lower BMI values in Indian children.

  17. High-resolution x-ray characterization of mosaic crystals for hard x-ray astronomy

    Science.gov (United States)

    Ferrari, Claudio; Buffagni, Elisa; Marchini, Laura; Zappettini, Andrea

    2012-04-01

    GaAs, Cu, CdTe, and CdZnTe crystals have been studied as optical elements for lenses for hard x-ray astronomy. High-resolution x-ray diffraction at 8 keV in Bragg geometry and at synchrotron at energies up to 500 keV in Laue geometry has been used. A good agreement was found between the mosaicity evaluated in Bragg geometry at 8 keV with x-ray penetration of the order of few tens of micrometers and that derived at synchrotron in transmission Laue geometry at higher x-ray energies. Mosaicity values in a range between a few to 150 arcsec were found in all the samples but, due to the presence of crystal grains in the cm range, CdTe and CdZnTe crystals were found not suitable. Cu crystals exhibit a mosaicity of the order of several arcmin; they indeed were found to be severely affected by cutting damage which could only be removed with a very deep etching. The full width at half maximum of the diffraction peaks decreased at higher x-ray energies showing that the peak broadening is affected by crystallite size. GaAs crystals grown by Czochralski method showed a mosaic spread up to 30 arcsec and good diffraction efficiency up to energies of 500 keV. The use of thermal treatments as a possible method to increase the mosaic spread was also evaluated.

  18. Comparison of the responses of TLD-100 and radiochromic films exposed to X-rays of low energy in a radiodiagnostic clinical treatment

    Energy Technology Data Exchange (ETDEWEB)

    Castro, M.; Mesa, F.; Sosa, M. [Physics Institute, University of Guanajuato, Loma del Bosque 103, Lomas del Campestre, 37150 Leon, Guanajuato (Mexico)

    2007-07-01

    Full text: In this work a comparison of the responses of a TLD-100 and a radiochromic film exposed to a low energy X-ray beam is presented. X-rays in the range of 20 to 120 KV from a clinical machine at the radiodiagnostic unit of the IMSS-Tl hospital in Leon were used. The processes of calibration of both the TLD-100 and the radiochromic films are also discussed. (Author)

  19. The simultaneous measurement of energy and linear polarization of the scattered radiation in resonant inelastic soft x-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Braicovich, L., E-mail: lucio.braicovich@polimi.it; Minola, M.; Dellea, G.; Ghiringhelli, G. [CNR-SPIN and Dipartimento di Fisica, Politecnico di Milano, piazza Leonardo Da Vinci 32, Milano I-20133 (Italy); Le Tacon, M. [Max-Planck-Institut für Festkörperforschung, Heisenbergstrasse 1, D-70569 Stuttgart (Germany); Moretti Sala, M.; Morawe, C.; Peffen, J.-Ch.; Yakhou, F.; Brookes, N. B. [European Synchrotron Radiation Facility, 71 Avenue des Martyrs, Grenoble F-38043 (France); Supruangnet, R. [Synchrotron Light Research Institute, Nakhon Ratchasima (Thailand)

    2014-11-15

    Resonant Inelastic X-ray Scattering (RIXS) in the soft x-ray range is an element-specific energy-loss spectroscopy used to probe the electronic and magnetic excitations in strongly correlated solids. In the recent years, RIXS has been progressing very quickly in terms of energy resolution and understanding of the experimental results, but the interpretation of spectra could further improve, sometimes decisively, from a full knowledge of the polarization of incident and scattered photons. Here we present the first implementation, in a high resolution soft-RIXS spectrometer used to analyze the scattered radiation, of a device allowing the measurement of the degree of linear polarization. The system, based on a graded W/B{sub 4}C multilayer mirror installed in proximity of the CCD detector, has been installed on the AXES spectrometer at the ESRF (European Synchrotron Radiation Facility); it has been fully characterized and it has been used for a demonstration experiment at the Cu L{sub 3} edge on a high-T{sub c} superconducting cuprate. The loss in efficiency suffered by the spectrometer equipped with this test facility was a factor 17.5. We propose also a more advanced version, suitable for a routine use on the next generation of RIXS spectrometers and with an overall efficiency up to 10%.

  20. Emission rates of Gd L sub-shell proton induced X-rays as a function of projectile energy

    Energy Technology Data Exchange (ETDEWEB)

    Canto, C.E.; Lucio, O.G. de, E-mail: olucio@comunidad.unam.mx; Pineda, J.C.

    2013-11-15

    In this work, relative intensities of Gd characteristic L X-ray were measured, which were induced by proton bombardment over a thin film made by deposition of GdF{sub 3} over a pyrolytic carbon substrate. Relative intensities were recorded as a function of the proton energy (ranging from 200 to 700 keV) and also as a function of a parameter defined as the reduced velocity of the incident particle. Results are presented as intensity ratios for the different L transitions observed, measured with respect to the total number of X-ray photons recorded; the energy dependence of the intensity ratios (L{sub β}/L{sub α},L{sub γ}/L{sub α},L{sub γ}/L{sub β},L{sub l}/L{sub α},L{sub l}/L{sub γ}) is shown and acquired data is compared with similar previous measurements, as well as with theoretical predictions [1] based on the ECPSSR theory and a 4th degree polynomial fit of data; a comparison between theoretical predictions and the polynomial fit was performed in order to provide an empirical correcting factor.

  1. Whole-body adipose tissue analysis: comparison of MRI, CT and dual energy X-ray absorptiometry

    DEFF Research Database (Denmark)

    Kullberg, J; Brandberg, J; Angelhed, J-E

    2009-01-01

    The aim of this study was to validate a recently proposed MRI-based T(1)-mapping method for analysis of whole-body adipose tissue (AT) using an established CT protocol as reference and to include results from dual energy X-ray absorptiometry (DEXA). 10 subjects, drawn from the Swedish Obese Subje......-processing of whole-body MRI data, allowing longitudinal whole-body studies that are also applicable for children and adolescents.......The aim of this study was to validate a recently proposed MRI-based T(1)-mapping method for analysis of whole-body adipose tissue (AT) using an established CT protocol as reference and to include results from dual energy X-ray absorptiometry (DEXA). 10 subjects, drawn from the Swedish Obese...... Subjects Sibling-pairs study, were examined using CT, MRI and DEXA. The CT analysis was based on 28 imaged slices. T(1) maps were calculated using contiguous MRI data from two different gradient echo sequences acquired using different flip angles. CT and MRI comparison was performed slice...

  2. Accelerator x-ray sources

    CERN Document Server

    Talman, Richard

    2007-01-01

    This first book to cover in-depth the generation of x-rays in particle accelerators focuses on electron beams produced by means of the novel Energy Recovery Linac (ERL) technology. The resulting highly brilliant x-rays are at the centre of this monograph, which continues where other books on the market stop. Written primarily for general, high energy and radiation physicists, the systematic treatment adopted by the work makes it equally suitable as an advanced textbook for young researchers.

  3. Compression of silver sulfide: X-ray diffraction measurements and total-energy calculations.

    Science.gov (United States)

    Santamaría-Pérez, David; Marqués, Miriam; Chuliá-Jordán, Raquel; Menendez, José M; Gomis, Oscar; Ruiz-Fuertes, Javier; Sans, Juan A; Errandonea, Daniel; Recio, José M

    2012-05-07

    Angle-dispersive X-ray diffraction measurements have been performed in acanthite, Ag(2)S, up to 18 GPa in order to investigate its high-pressure structural behavior. They have been complemented by ab initio electronic structure calculations. From our experimental data, we have determined that two different high-pressure phase transitions take place at 5 and 10.5 GPa. The first pressure-induced transition is from the initial anti-PbCl(2)-like monoclinic structure (space group P2(1)/n) to an orthorhombic Ag(2)Se-type structure (space group P2(1)2(1)2(1)). The compressibility of the lattice parameters and the equation of state of both phases have been determined. A second phase transition to a P2(1)/n phase has been found, which is a slight modification of the low-pressure structure (Co(2)Si-related structure). The initial monoclinic phase was fully recovered after decompression. Density functional and, in particular, GGA+U calculations present an overall good agreement with the experimental results in terms of the high-pressure sequence, cell parameters, and their evolution with pressure.

  4. A numerical model for multiple detector energy dispersive X-ray spectroscopy in the transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Xu, W.; Dycus, J.H.; Sang, X.; LeBeau, J.M., E-mail: jmlebeau@ncsu.edu

    2016-05-15

    Here we report a numerical approach to model a four quadrant energy dispersive X-ray spectrometer in the transmission electron microscope. The model includes detector geometries, specimen position and absorption, shadowing by the holder, and filtering by the Be carrier. We show that this comprehensive model accurately predicts absolute counts and intensity ratios as a function of specimen tilt and position. We directly compare the model to experimental results acquired with a FEI Super-X EDS four quadrant detector. The contribution from each detector to the sum is investigated. The program and source code can be downloaded from (https://github.com/subangstrom/superAngle). - Highlights: • A novel numeric model is developed to predict the effective detector collection angle for multi-detector EDS in the transmission electron microscope. • The precise geometry of specimen holder is incorporated to determine the influence of holder shadowing • The role of X-ray filtering by the Be specimen carrier is investigated. • Predicted counts and intensity ratios are directly compared to experiment as a function of tilt and are shown to be in excellent agreement • The detector intensity sum effectively reduces errors compared to the individual detector signals.

  5. Stature estimation based on vertebral morphometry by dual energy X-rays absorptiometry imaging in Italian females

    Directory of Open Access Journals (Sweden)

    Chantal Milani

    2017-02-01

    Full Text Available Anthropological profile in forensic context includes the assessment of parameters as ancestry, sex, age and stature of an individual by the analysis of skeletal remains. Stature can be estimated from decomposed and fully or partially skeletonized remains by means of anatomical or mathematical methods applied on the whole skeleton or single bones. Many authors calculated regression formulae for the living stature estimation by these methods, in particular based on a population similar to the remains recovered. Long bones are commonly used for stature estimation, but, when they are missing, methods involving different parts of the skeleton are needed. In this preliminary study we measured heights of the vertebral bodies in a female Caucasian Italian population, evaluated by images of morphometric X-ray absorptiometry based on dual-energy X-ray absorptiometry in living subjects investigated for routine diagnostic purposes. Thoracic and lumbar segments of the spine were measured and statistical analysis was performed, thus obtaining regression formulae for estimated living stature from thoraco-lumbar spine segments (T6-T12, L1-L4 and T6-L4. We propose this method for stature evaluation in physical or forensic anthropology when the spine is available and long bones are missing.

  6. Determination of selenium at trace levels in geologic materials by energy-dispersive X-ray fluorescence spectrometry

    Science.gov (United States)

    Wahlberg, J.S.

    1981-01-01

    Low levels of selenium (0.1-500 ppm) in both organic and inorganic geologic materials can be semiquantitatively measured by isolating Se as a thin film for presentation to an energy-dispersive X-ray fluorescence spectrometer. Suitably pulverized samples are first digested by fusing with a mixture of Na2CO3 and Na2O2. The fusion cake is dissolved in distilled water, buffered with NH4Cl, and filtered to remove Si and the R2O3 group. A carrier solution of Na2TeO4, plus solid KI, hydrazine sulfate and Na2SO3, is added to the filtrate. The solution is then vacuum-filtered through a 0.45-??m pore-size filter disc. The filter, with the thin film of precipitate, is supported between two sheets of Mylar?? film for analysis. Good agreement is shown between data reported in this study and literature values reported by epithermal neutron-activation analysis and spectrofluorimetry. The method can be made quantitative by utilizing a secondary precipitation to assure complete recovery of the Se. The X-ray method offers fast turn-around time and a reasonably high production rate. ?? 1981.

  7. Energy dispersive X-ray diffraction applied to laboratory investigation on proton exchange membrane water content in working fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Isopo, A.; Rossi Albertini, V. [Istituto di Struttura della Materia - CNR, Roma (Italy); Nobili, F. [Scuola di Scienze e Tecnologie - Sezione Chimica, Universita degli Studi di Camerino (Italy)

    2012-10-15

    An original method, based on the energy-dispersive X-ray diffraction, has been recently proposed as a possible laboratory tool to accomplish long time resolved investigation of the water content in a proton exchange membrane fuel cell. However, this method has never been applied to a real working fuel cell. Therefore, a clear comprehension of its effectiveness in terms of relevant parameters such as time and space resolution, sensitivity, and reproducibility has not yet been achieved. In this paper, all these aspects are discussed and clarified. In order to focus on the method overall effectiveness and on the extent of possible improvements, a basic experimental configuration for both the electrochemical station and the X-ray equipment has been set. The method is described with particular attention to its operating principle and to the evaluation of the errors introduced in data assessment. Finally, applications to some model experiments, in particular working states of the device, are provided and the obtained results are discussed. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. Energy gaps, electronic structures, and x-ray spectroscopies of finite semiconductor single-walled carbon nanotubes.

    Science.gov (United States)

    Gao, Bin; Jiang, Jun; Wu, ZiYu; Luo, Yi

    2008-02-28

    We report hybrid density functional theory calculations for electronic structures of hydrogen-terminated finite single-walled carbon nanotubes (6,5) and (8,3) up to 100 nm in length. Gap states that are mainly arisen from the hydrogen-terminated edges have been found in (8,3) tubes, but their contributions to the density of states become invisible when the tube is longer than 10 nm. The electronic structures of (6,5) and (8,3) tubes are found to be converged around 20 nm. The calculated band-gap energies of 100 nm long nanotubes are in good agreement with experimental results. The valence band structures of (6,5), (8,3), as well as (5,5) tubes are also investigated by means of ultraviolet photoelectron spectra (UPS), x-ray emission spectroscopy (XES), and the resonant inelastic x-ray scattering (RIXS) spectra theoretically. The UPS, XES and RIXS spectra become converged already at 10 nm. The length-dependent oscillation behavior is found in the RIXS spectra of (5,5) tubes, indicating that the RIXS spectra may be used to determine the size and length of metallic nanotubes. Furthermore, the chiral dependence observed in the simulated RIXS spectra suggests that RIXS spectra could be a useful technique for the determination of chirality of carbon nanotubes.

  9. Pin-photodiode array for the measurement of fan-beam energy and air kerma distributions of X-ray CT scanners.

    Science.gov (United States)

    Haba, Tomonobu; Koyama, Shuji; Aoyama, Takahiko; Kinomura, Yutaka; Ida, Yoshihiro; Kobayashi, Masanao; Kameyama, Hiroshi; Tsutsumi, Yoshinori

    2016-07-01

    Patient dose estimation in X-ray computed tomography (CT) is generally performed by Monte Carlo simulation of photon interactions within anthropomorphic or cylindrical phantoms. An accurate Monte Carlo simulation requires an understanding of the effects of the bow-tie filter equipped in a CT scanner, i.e. the change of X-ray energy and air kerma along the fan-beam arc of the CT scanner. To measure the effective energy and air kerma distributions, we devised a pin-photodiode array utilizing eight channels of X-ray sensors arranged at regular intervals along the fan-beam arc of the CT scanner. Each X-ray sensor consisted of two plate type of pin silicon photodiodes in tandem - front and rear photodiodes - and of a lead collimator, which only allowed X-rays to impinge vertically to the silicon surface of the photodiodes. The effective energy of the X-rays was calculated from the ratio of the output voltages of the photodiodes and the dose was calculated from the output voltage of the front photodiode using the energy and dose calibration curves respectively. The pin-photodiode array allowed the calculation of X-ray effective energies and relative doses, at eight points simultaneously along the fan-beam arc of a CT scanner during a single rotation of the scanner. The fan-beam energy and air kerma distributions of CT scanners can be effectively measured using this pin-photodiode array. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. Overestimations in zero frequency DQE of x-ray imaging converters assessed by Monte Carlo techniques based on the study of energy impartation events

    Energy Technology Data Exchange (ETDEWEB)

    Liaparinos, P. F.; Kandarakis, I. S. [Department of Medical Instruments Technology, Technological Educational Institute, 122 10 Athens (Greece)

    2011-07-15

    Purpose: The performance of various x-ray converters, employed in medical imaging systems, has been widely examined by several methodologies (experimental, analytical, and Monte Carlo techniques). The x-ray converters most frequently employed in energy integrating digital radiology detectors are the Gd{sub 2}O{sub 2}S:Tb granular phosphor, the CsI:Tl structured phosphor, and the a-Se photoconductor. The imaging characteristics of an x-ray converter are affected by its x-ray detection properties. However, various definitions of x-ray detection have been used in the literature, leading to different results for the quantum detection efficiency (QDE) for the same type of x-ray converter. For this reason, there is a need for accurate determination of the x-ray detection and, in particular, its relation to detector response. Methods: The present article reports on the performance of the three aforementioned x-ray converters in terms of the QDE and the x-ray statistical factor I{sub x} and examines the effect of the x-ray detection, directly related to converter output signal, on the zero-frequency DQE. For the purposes of this study, Monte Carlo simulation was used to model the x-ray interactions within the x-ray converter. Simulations were carried out in the energy range from 10 keV up to 80 keV and considering two layers of different coating weights (50 and 100 mg/cm{sup 2}). The prediction and comparison of zero-frequency DQE were based on two different approaches for x-ray detection, i.e., (a) fraction of interacting photons and (b) fraction of photons leading to energy deposition. In addition, the effect of energy deposition through Compton scattering events on the DQE values was estimated. Results: Our results showed discrepancies between Monte Carlo techniques (based on energy deposition events) and analytical calculations (based on x-ray attenuation) on QDE. Discrepancies were found to range up to 10% for Gd{sub 2}O{sub 2}S:Tb (100 mg/cm{sup 2}), 7.7% for Cs

  11. Intense soft X-ray flux from Her-1

    Science.gov (United States)

    Catura, R. C.; Acton, L. W.

    1976-01-01

    An intense flux of soft X-rays extending up to at least 1 keV has been observed from Her X-1. If the soft X-ray intensity is corrected for interstellar absorption the luminosity between 0.16 and 1 keV is comparable to that from 2-10 keV. The soft X-rays are modulated with the 1.24 sec period observed at higher energies but are approximately 180 deg out of phase with the high energy flux. These results extend the detection of this flux to higher energy, a different binary phase, and to a time 19 periods (of the 35 day cycle) later. These observations suggest that this soft emission is a stable feature in the spectrum of this source during its X-ray on state and that this emission is local to Her X-1.

  12. Monochromatic Mammographic Imaging Using X-ray Polycapillary Optics

    National Research Council Canada - National Science Library

    Sugiro, Francisca

    2000-01-01

    .... Monochromatic x rays can be used to produce higher contrast images. Polycapillary x-ray optics technology can produce a highly parallel, monochromatic, x-ray beam from a conventional radiographic source...

  13. Dual-energy synchrotron X ray measurements of rapid soil density and water content changes in swelling soils during infiltration

    Science.gov (United States)

    Garnier, Patricia; Angulo-Jaramillo, Rafael; DiCarlo, David A.; Bauters, Tim W. J.; Darnault, Christophe J. G.; Steenhuis, Tammo S.; Parlange, J.-Yves; Baveye, Philippe

    1998-11-01

    Understanding soil swelling is hampered by the difficulty of simultaneously measuring water content and bulk density. A number of studies have used dual-energy gamma rays to investigate soil swelling. The long counting time of this technique makes it impracticable for studying the rapid changes in moisture content and soil swelling shortly after infiltration is initiated. In this paper, we use the dual-energy synchrotron X ray to measure, for the first time, the water content and bulk density changes during the fast, initial phase of the swelling process. Ponded infiltration experiments were performed with two soils: a bentonite-sand mixture and a vertisol. Swelling curves and hydraulic diffusivity were determined. Deformation was very rapid immediately after water application and then became progressively slower. The hydraulic diffusivity decreased with time, which can partially explain the very rapid decrease in infiltration rates observed in the field.

  14. Study of Mechanical Properties of Bone by Measuring Load Transfer via High-energy X-ray Diffraction

    Science.gov (United States)

    Singhal, Anjali

    Synchrotron high-energy X-ray scattering is used to investigate the in situ strains in hydroxyapatite (HAP) platelets and mineralized collagen fibrils in bovine cortical bone. Compressive load-unload tests at room temperature (27°C) and body temperature (37°C) show that the load transfer to the stiff nano-sized platelets from the surrounding compliant protein matrix does not vary significantly with temperature. This emphasizes that the stiffness of bone is controlled by the stiffness of the HAP phase, which remains unaffected by this change in temperature. Monotonic loading tests in compression and tension, conducted at 37°C, illustrate the spatial variation of properties within a single femur, which is correlated to the mineral content, porosity and microstructure of the samples. The average apparent modulus of HAP and fibrils (EappHAP and Eappfib, respectively), defined as the ratio of applied stress and phase strain, is obtained as 27.5 ± 6.6 and 18.5 ± 8.9 GPa, respectively, in compression. These values are significantly higher than the values of 20.0 ± 5.4 and 4.1 ± 2.6 GPa obtained for HAP and fibrils, respectively, in tension. The difference between the two types of loading is attributed to greater plastic deformation of collagen in tension, which results in greater strains in the collagen fibril, and concomitant greater load transfer to the HAP. Increasing synchrotron X-ray doses (5-3880 kGy) affect neither apparent HAP nor fibrillar modulus, up to stresses of -60 MPa (measured during in situ loading and unloading). However, the residual elastic strains in the HAP phase decrease markedly with increased irradiation, indicating damage at the HAP-collagen interface. Analysis of the X-ray diffraction peak widths shows that unit cells of HAP which are under the highest initial residual strains are most able to relax due to irradiation, resulting in a net decrease in the strain distribution (RMS strain). The constancy of apparent moduli is explained by

  15. X-Ray Calorimeter Arrays for Astrophysics

    Science.gov (United States)

    Kilbourne, Caroline A.

    2009-01-01

    High-resolution x-ray spectroscopy is a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites started a new era in x-ray astronomy, but there remains a need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band (around 6 keV) and can enable imaging spectroscopy of extended sources, such as supernova remnants and galaxy clusters. The instrumentation needed is a broad-band imaging spectrometer - basically an x-ray camera that can distinguish tens of thousands of x-ray colors. The potential benefits to astrophysics of using a low-temperature calorimeter to determine the energy of an incident x-ray photon via measurement of a small change in temperature was first articulated by S. H. Moseley over two decades ago. In the time since, technological progress has been steady, though full realization in an orbiting x-ray telescope is still awaited. A low-temperature calorimeter can be characterized by the type of thermometer it uses, and three types presently dominate the field. The first two types are temperature-sensitive resistors - semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a paramagnetic thermometer. These types can be considered the three generations of x-ray calorimeters; by now each has demonstrated a resolving power of 2000 at 6 keV, but only a semiconductor calorimeter system has been developed to spaceflight readiness. The Soft X-ray Spectrometer on Astro-H, expected to launch in 2013, will use an array of silicon thermistors with I-IgTe x-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays, kilo-pixel arrays of the superconducting calorimeters are just now being produced, and it is anticipated that much larger arrays will require the non-dissipative advantage of magnetic thermometers.

  16. Proposal to DOE Basic Energy Sciences: Ultrafast X-ray science facility at the Advanced Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Schoenlein, Robert W.; Falcone, Roger W.; Abela, R.; Alivisatos, A.P.; Belkacem, A.; Berrah, N.; Bozek, J.; Bressler, C.; Cavalleri, A.; Chergui, M.; Glover, T.E.; Heimann, P.A.; Hepburn, J.; Larsson, J.; Lee, R.W.; McCusker, J.; Padmore, H.A.; Pattison, P.; Pratt, S.T.; Shank, C.V.; Wark, J.; Chang, Z.; Robin, D.W.; Schlueter, R.D.; Zholents, A.A.; Zolotorev, M.S.

    2001-12-12

    We propose to develop a true user facility for ultrafast x-ray science at the Advanced Light Source. This facility will be unique in the world, and will fill a critical need for the growing ultrafast x-ray research community. The development of this facility builds upon the expertise from long-standing research efforts in ultrafast x-ray spectroscopy and the development of femtosecond x-ray sources and techniques at both the Lawrence Berkeley National Laboratory and at U.C. Berkeley. In particular, the technical feasibility of a femtosecond x-ray beamline at the ALS has already been demonstrated, and existing ultrafast laser technology will enable such a beamline to operate near the practical limit for femtosecond x-ray flux and brightness from a 3rd generation synchrotron.

  17. FLUORESCENT X-RAY IMAGING WITH PINHOLE CAMERA

    Directory of Open Access Journals (Sweden)

    Yu. I. Dudchik

    2016-01-01

    Full Text Available Pinhole camera is one of X-ray optics devices. The pinhole camera is used for obtaining the image of synchrotron and laboratory sources, and also as a lens in a method of X-ray fluorescent microscopy. This method allows to obtain information on a spatial distribution of various chemical elements to the areas of several square centimeters with spatial resolution at the level of 50–100 μm. As a rule energy-dispersive two-dimensional CCD cameras are used for imaging. Such cameras are expensive devices and have low sensitivity for X-rays with energy of photons higher than 8 keV. Therefore it is perspective to use for X-ray fluorescent microscopy more effective CCD cameras with a scintillator layer. The purpose of this work consists in development of the device for imaging with secondary fluorescent X-rays by using pinhole as a lens and CCD camera for registration of the X-ray image. The device for obtaining the image of objects in secondary X-rays is developed. The device consists of an X-ray tube, pinhole and CCD camera. The object of research was irradiated with radiation from the X-ray tube and emits secondary X-rays. 100-microns pinhole was used for formation of the image of the object at an entrance window of the CCD camera. Images of a number of the iron springs differing in the sizes are received. It is established that the spatial resolution of the device is about 200 μm at an exposition of 60 s. It is possible to improve permission of the device by increasing in an exposition, optimization imaging conditions and reduction of the pinhole size. 

  18. Analysis of hard X-ray emission from selected very high energy {gamma}-ray sources observed with INTEGRAL

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Agnes Irene Dorothee

    2009-11-13

    A few years ago, the era of very high energy {gamma}-ray astronomy started, when the latest generation of Imaging Atmospheric Cherenkov Telescopes (IACT) like H.E.S.S. began to operate and to resolve the sources of TeV emission. Identifications via multi-wavelength studies reveal that the detected sources are supernova remnants and active galactic nuclei, but also pulsar wind nebulae and a few binaries. One widely discussed open question is, how these sources are able to accelerate particles to such high energies. The understanding of the underlying particle distribution, the acceleration processes taking place, and the knowledge of the radiation processes which produce the observed emission, is, therefore, of crucial interest. Observations in the hard X-ray domain can be a key to get information on these particle distributions and processes. Important for this thesis are the TeV and the hard X-ray range. The two instruments, H.E.S.S. and INTEGRAL, whose data were used, are, therefore, described in detail. The main part of this thesis is focused on the X-ray binary system LS 5039/RX J1826.2-1450. It was observed in several energy ranges. The nature of the compact object is still not known, and it was proposed either to be a microquasar system or a non-accreting pulsar system. The observed TeV emission is modulated with the orbital cycle. Several explanations for this variability have been discussed in recent years. The observations with INTEGRAL presented in this thesis have provided new information to solve this question. Therefore, a search for a detection in the hard X-ray range and for its orbital dependence was worthwhile. Since LS 5039 is a faint source and the sky region where it is located is crowded, a very careful, non-standard handling of the INTEGRAL data was necessary, and a cross-checking with other analysis methods was essential to provide reliable results. We found that LS 5039 is emitting in the hard X-ray energy range. A flux rate and an upper

  19. Application of the Monte Carlo codes PENELOPE and MCNP5 to unfold X-ray spectra in the diagnostic energy range

    Science.gov (United States)

    Gallardo, Sergio; Querol, Andrea; Pozuelo, Fausto; Verdú, Gumersindo; Ródenas, José

    2014-02-01

    Obtaining primary X-ray spectra is a complex task, mainly due to the high fluence of X-rays. In order to avoid the pile up effect in the detector, an indirect method based on the Compton scattering interactions in a low density rod material can be successfully applied in the diagnostic energy range. In this work, the Monte Carlo codes PENELOPE and MCNP5 have been used to simulate the indirect method based on a simplified Compton spectrometry technique. Both models include the X-ray focus, a poly(mehtylmethacrylate) (PMMA) rod and an HPGe detector. Because the probability that primary photons scattered in the PMMA will be emitted towards the detector is small, it is necessary to consider appropriate values for cut-offs and other simulation parameters. With these models, a response function can be determined, relating the response of the detector to the primary X-ray spectrum. This function can be normally expressed as a matrix, which can be calculated by simulating the response detector to several monochromatic X-ray beams. The main goal of this work is to test the capability of the Monte Carlo codes PENELOPE and MCNP5, together with unfolding methods to estimate the primary spectrum when the response matrix and the response of the detector for a given conditions are known. The reliability of unfolded X-ray spectra is studied by comparing them with theoretical spectra obtained from the IPEM 78 catalog and calculating the Root Mean Squared (RMS) and Quality parameters.

  20. A catalogue of optical to X-ray spectral energy distributions of z ≈ 2 quasars observed with Swift - I. First results

    Science.gov (United States)

    Lawther, D.; Vestergaard, M.; Raimundo, S.; Grupe, D.

    2017-06-01

    We present the Swift optical to X-ray spectral energy distributions (SEDs) of 44 quasars at redshifts z ≈ 2 observed by Swift, part of a larger program to establish and characterize the optical through X-ray SEDs of moderate-redshift quasars. Here, we outline our analysis approach and present preliminary analysis and results for the first third of the full quasar sample. Not all quasars in the sample are detected in X-rays; all of the X-ray-detected objects so far are radio loud. As expected for radio-loud objects, they are X-ray bright relative to radio-quiet quasars of comparable optical luminosities, with an average αox =1.39 ± 0.03 (where αox is the power-law slope connecting the monochromatic flux at 2500 Å and at 2 keV), and display hard X-ray spectra. We find integrated 3000 Å-25 keV accretion luminosities of between 0.7 × 1046 erg s-1 and 5.2 × 1047 erg s-1. Based on single-epoch spectroscopic virial black hole mass estimates, we find that these quasars are accreting at substantial Eddington fractions, 0.1 ≲ L/LEdd ≲ 1.

  1. Validity of Skinfold Equations, Against Dual-Energy X-Ray Absorptiometry, in Predicting Body Composition in Adolescent Pentathletes.

    Science.gov (United States)

    Fonseca-Junior, Sidnei Jorge; Oliveira, Aldair J; Loureiro, Luiz Lannes; Pierucci, Anna Paola Trindade

    2017-05-01

    Body composition of adolescent athletes is often evaluated scientifically and in sports by using reference equations developed from nonathlete adolescent populations. The aim of this study was to analyze the validity of predictive equations based on skinfold measurements, as compared with dual-energy X-ray absorptiometry (DXA), to estimate body fat in adolescent modern pentathlon athletes. 51 athletes, 27 male (mean age = 15.1 years; standard deviation, SD = 1.5 years) and 24 female (mean age = 14.2 years; SD = 2.5 years), were assessed using DXA, anthropometric parameters, sports practice anamnesis, and pubertal stages. Agreement between methods was tested with boxplots of mean comparisons using Student's t test (p .05), but they did display high variability (2SD). The high variability among results indicated imprecision. Predictive skinfold equations developed for nonathlete adolescents do not offer good validity for modern adolescent pentathlon athletes, and should be avoided.

  2. Measurement precision of body composition variables in elite wheelchair athletes, using dual-energy X-ray absorptiometry.

    Science.gov (United States)

    Keil, Mhairi; Totosy de Zepetnek, Julia O; Brooke-Wavell, Katherine; Goosey-Tolfrey, Victoria L

    2016-01-01

    The purpose of this study was to assess the reproducibility of body composition measurements by dual-energy X-ray absorptiometry (DXA) in 12 elite male wheelchair basketball players (age 31 ± 7 years, BMI 21 ± 2 kg/m(2) and onset of disability 25 ± 9 years). Two whole body scans were performed on each participant in the supine position on the same day, using Lunar Prodigy Advance DXA (GE Lunar, Madison, WI, USA). Participants dismounted from the scanning table and were repositioned in-between the first and second scan. Whole body coefficient of variation (CV) values for bone mineral content (BMC), fat mass (FM) and soft tissue lean mass (LTM) were all wheelchair basketball athletes.

  3. Comparison of Dual Energy X-ray Absorptiometry and Bioimpedance in Assessing Body Composition and Nutrition in Peritoneal Dialysis Patients

    DEFF Research Database (Denmark)

    Popovic, Velena; Zerahn, Bo; Heaf, James Goya

    2017-01-01

    OBJECTIVE: Peritoneal dialysis (PD) patients are characterized by protein malnutrition and muscle wasting. Reliable, easy, and cheap methods for evaluating nutrition are desirable. Three methods are commonly available: dual-energy X-ray absorptiometry (DXA), bioimpedance (BI), and subjective global...... affecting the differences were FT, ICW, LTM, and ICW. Obesity (DXA 43%; BI 54%) and muscle wasting (BI 28%; SGA 53%) were common. Agreement between BI and SGA was poor. Thirty-eight percent of patients judged malnourished by SGA also had a low LTI; 23% with normal SGA had low LTI. SGA was closer related...... to LTI (BI) than LTI (DXA). Plasma albumin was correlated to LTI, FTI, and ICW/ht, and comorbidity to OH, clinical malnutrition, reduced FTI, but not LTI. CONCLUSION: Agreement between DXA and BI was high on a population basis but not at an individual level. Obesity and muscle wasting were common...

  4. Measurement of Trace Constituents by Electron-Excited X-Ray Microanalysis with Energy-Dispersive Spectrometry.

    Science.gov (United States)

    Newbury, Dale E; Ritchie, Nicholas W M

    2016-06-01

    Electron-excited X-ray microanalysis performed with scanning electron microscopy and energy-dispersive spectrometry (EDS) has been used to measure trace elemental constituents of complex multielement materials, where "trace" refers to constituents present at concentrations below 0.01 (mass fraction). High count spectra measured with silicon drift detector EDS were quantified using the standards/matrix correction protocol embedded in the NIST DTSA-II software engine. Robust quantitative analytical results for trace constituents were obtained from concentrations as low as 0.000500 (mass fraction), even in the presence of significant peak interferences from minor (concentration 0.01≤C≤0.1) and major (C>0.1) constituents. Limits of detection as low as 0.000200 were achieved in the absence of peak interference.

  5. Simple procedure for nutrient analysis of coffee plant with energy dispersive X-ray fluorescence spectrometry (EDXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Tezotto, Tiago; Favarin, Jose Laercio; Neto, Ana Paula; Azevedo, Ricardo Antunes, E-mail: tiago.tezotto@usp.br [Escola Superior de Agricultura Luiz de Queiroz (ESALQ/USP), Piracicaba, SP (Brazil); Gratao, Priscila Lupino [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP/ FCAV), Jaboticabal, SP (Brazil). Dept. de Biologia Aplicada a Agropecuaria; Mazzafera, Paulo [Universidade Estadual de Campinas (UNICAMP/IB), SP (Brazil). Dept. Biologia Vegetal

    2013-07-15

    Nutrient analysis is used to estimate nutrient content of crop plants to manage fertilizer application for sustained crop production. Direct solid analysis of agricultural and environmental samples by energy dispersive X-ray fluorescence spectrometry (EDXRF) was chosen as alternative technique to evaluate the simultaneous multielemental quantification of the most important essential elements in coffee (Coffea arabica L.) plants. Inductively coupled plasma atomic emission spectrometry and certified reference materials made from leaves were used to calibrate and check the trueness of EDXRF method for the determination of the concentration of several nutrients in coffee leaves and branches. Fluorescence spectrometry proved to be advantageous and presented low cost as loose powder samples could be used. Samples collected from a field experiment where coffee plants were treated with excess of Ni and Zn were used to verify the practical application of the method. Good relationships were achieved between certified values and data obtained by EDXRF, with recoveries ranging from 82 to 117 %.(author)

  6. Trace elemental analysis of school chalk using energy dispersive X-ray florescence spectroscopy (ED-XRF)

    Science.gov (United States)

    Maruthi, Y. A.; Das, N. Lakshmana; Ramprasad, S.; Ram, S. S.; Sudarshan, M.

    2015-08-01

    The present studies focus the quantitative analysis of elements in school chalk to ensure the safety of its use. The elements like Calcium (Ca), Aluminum (Al), Iron (Fe), Silicon (Si) and Chromium (Cr) were analyzed from settled chalk dust samples collected from five classrooms (CD-1) and also from another set of unused chalk samples collected from local market (CD-2) using Energy Dispersive X-Ray florescence(ED-XRF) spectroscopy. Presence of these elements in significant concentrations in school chalk confirmed that, it is an irritant and occupational hazard. It is suggested to use protective equipments like filtered mask for mouth, nose and chalk holders. This study also suggested using the advanced mode of techniques like Digital boards, marker boards and power point presentations to mitigate the occupational hazard for classroom chalk

  7. A novel technique for single-shot energy-resolved 2D x-ray imaging of plasmas relevant for the inertial confinement fusion.

    Science.gov (United States)

    Labate, L; Köster, P; Levato, T; Gizzi, L A

    2012-10-01

    A novel x-ray diagnostic of laser-fusion plasmas is described, allowing 2D monochromatic images of hot, dense plasmas to be obtained in any x-ray photon energy range, over a large domain, on a single-shot basis. The device (named energy-encoded pinhole camera) is based upon the use of an array of many pinholes coupled to a large area CCD camera operating in the single-photon mode. The available x-ray spectral domain is only limited by the quantum efficiency of scientific-grade x-ray CCD cameras, thus extending from a few keV up to a few tens of keV. Spectral 2D images of the emitting plasma can be obtained at any x-ray photon energy provided that a sufficient number of photons had been collected at the desired energy. Results from recent inertial confinement fusion related experiments will be reported in order to detail the new diagnostic.

  8. Study of Pd/Y based multilayers using high energy photoemission spectroscopy combined with x-ray standing waves

    Science.gov (United States)

    Wu, M.-Y.; Ilakovac, V.; André, J.-M.; Le Guen, K.; Giglia, A.; Rueff, J.-P.; Huang, Q.-S.; Wang, Z.-S.; Jonnard, P.

    2017-05-01

    We use hard x-ray photoemission spectroscopy combined with x-ray standing waves to characterize a series of Pd/Y multilayers designed to work in the 7.5-11 nm wavelength range. The samples, prepared by magnetron sputtering, are deposited either with or without nitrogen introduced in the sputtering gas. The aimed period of the samples is 4 nm. The experiments consist in obtaining the core level spectra of the various elements for a series of grazing angles. The angular scan is made in the range given by the Bragg law, the multilayer period and the incident photon energy. Given the period of the multilayer and the presence of a 2.5 nm-thick B4C capping layer, the photon energy is chosen to be 10 keV in order to probe the first 5-6 periods of the stack. Thus the Bragg angle is a little less than 1°. Rotating the sample enables putting the nodes of the electric field at some particular location of the stack, thus to make the excitation depth-selective, probing one interface or another or the center of one given layer. The changes of the chemical shift in the Pd 2p and 3d, Y 2p and 3d, O 1s, N 1s, C 1s and B 1s as a function of the angle, that is to say as a function of the location in the stack will give information about the possible interfacial process taking place in the Pd/Y multilayers.

  9. Energy dispersive X-ray analysis of titanium dioxide nanoparticle distribution after intravenous and subcutaneous injection in mice.

    Science.gov (United States)

    Patri, Anil; Umbreit, Thomas; Zheng, J; Nagashima, K; Goering, Peter; Francke-Carroll, Sabine; Gordon, Edward; Weaver, James; Miller, Terry; Sadrieh, Nakissa; McNeil, Scott; Stratmeyer, Mel

    2009-11-01

    In an effort to understand the disposition and toxicokinetics of nanoscale materials, we used EDS (energy dispersive X-ray spectroscopy) to detect and map the distribution of titanium dioxide (TiO2) in tissue sections from mice following either subcutaneous (s.c.) or intravenous (i.v.) injection. TiO2 nanoparticles were administered at a dose of 560 mg/kg (i.v.) or 5600 mg/kg (s.c.) to Balb/c female mice on two consecutive days. Tissues (liver, kidney, lung, heart, spleen, and brain) were examined by light microscopy, TEM (transmission electron microscopy), SEM (scanning electron microscopy), and EDS following necropsy one day after treatment. Particle agglomerates were detected by light microscopy in all tissues examined, EDS microanalysis was used to confirm that these tissues contained elemental titanium and oxygen. The TEM micrographs and EDS spectra of the aggregates were compared with in vitro measurements of TiO2 nanoparticle injection solution (i.e., in water). The nanoparticles were also characterized using dynamic light scattering in water, 10 mM NaCl, and phosphate buffered saline (PBS). In low ionic strength solvents (water and 10 mM NaCl), the TiO2 particles had average hydrodynamic diameters ranging from 114-122 nm. In PBS, however, the average diameter increases to 1-2 microm, likely due to aggregation analogous to that observed in tissue by TEM and EDS. This investigation demonstrates the suitability of energy dispersive X-ray spectroscopy (EDS) for detection of nanoparticle aggregates in tissues and shows that disposition of TiO2 nanoparticles depends on the route of administration (i.v. or s.c.).

  10. Chest X-Ray

    Medline Plus

    Full Text Available ... the most commonly performed x-ray exams and use a very small dose of ionizing radiation to ... to your health. While a chest x-ray use a tiny dose of ionizing radiation, the benefit ...

  11. X-ray data booklet. Revision

    Energy Technology Data Exchange (ETDEWEB)

    Vaughan, D. (ed.)

    1986-04-01

    A compilation of data is presented. Included are properties of the elements, electron binding energies, characteristic x-ray energies, fluorescence yields for K and L shells, Auger energies, energy levels for hydrogen-, helium-, and neonlike ions, scattering factors and mass absorption coefficients, and transmission bands of selected filters. Also included are selected reprints on scattering processes, x-ray sources, optics, x-ray detectors, and synchrotron radiation facilities. (WRF)

  12. Abdominal fat indicators: anthropometry vs dual energy x-ray absortometry

    Directory of Open Access Journals (Sweden)

    Maria Fátima Glaner

    2008-06-01

    Full Text Available Excessive abdominal fat contributes to the development of chronic nontransmissible diseases. Dual emission X Ray absorptiometry (DXA is a simple to administer technique that allows abdominal fat percentage (%abdominalFDXA to be determined. Anthropometric measurements, which have been validated and are of low cost, such as the abdominal circumferences 2.5cm above the umbilical scar (ABC2,5 and level with the umbilical scar (ABCum, are used as indicators of abdominal fat. Skin folds (SF are little used for this purpose. The objective of this study was to verify which of these anthropometric indicators best correlates with and best explains abdominalFDXA. The sample was made up of 22 women (43.9±11.6 years; 34.7±8.3 %G totalDXA and 18 men (31.9±11.6 years; 19.0±8.0 %G totalDXA who were measured for ABC2.5, ABCum, suprailiac SF (SI, midaxillary SF (AM and abdominal SF (AB, while abdominalF (L1-L4 was measured by DXA. Pearson’s correlation and multivariate linear regression (“enter” method were employed to verify the anthropometric measurements’ correlations and percentage of explanation with relation to abdominalFDXA. Strong correlations and significant levels of explanation (pResumoO excesso de gordura abdominal contribui no desenvolvimento de doenças crônicas não-transmissíveis. A absortometria de raio-X de dupla energia (AXDE é uma técnica de simples aplicação, que permite a mensuração do percentual de gordura abdominal (%G abdominalAXDE. As medidas antropométricas, validadas e de baixo custo, como os perímetros abdominal 2,5cm acima da cicatriz umbilical (PAB2,5 e ao nível da cicatriz umbilical (PABum, são empregadas como indicadores de gordura abdominal. As dobras cutâneas (DC são pouco estudadas nesse sentido. Assim, o objetivo desse estudo foi verificar quais destes indicadores antropométricos mais se correlacionam e explicam o %G abdominalAXDE. A amostra foi composta por 22 mulheres (43,9±11,6 anos; 34,7±8,3 %G

  13. A novel material detection algorithm based on 2D GMM-based power density function and image detail addition scheme in dual energy X-ray images.

    Science.gov (United States)

    Pourghassem, Hossein

    2012-01-01

    Material detection is a vital need in dual energy X-ray luggage inspection systems at security of airport and strategic places. In this paper, a novel material detection algorithm based on statistical trainable models using 2-Dimensional power density function (PDF) of three material categories in dual energy X-ray images is proposed. In this algorithm, the PDF of each material category as a statistical model is estimated from transmission measurement values of low and high energy X-ray images by Gaussian Mixture Models (GMM). Material label of each pixel of object is determined based on dependency probability of its transmission measurement values in the low and high energy to PDF of three material categories (metallic, organic and mixed materials). The performance of material detection algorithm is improved by a maximum voting scheme in a neighborhood of image as a post-processing stage. Using two background removing and denoising stages, high and low energy X-ray images are enhanced as a pre-processing procedure. For improving the discrimination capability of the proposed material detection algorithm, the details of the low and high energy X-ray images are added to constructed color image which includes three colors (orange, blue and green) for representing the organic, metallic and mixed materials. The proposed algorithm is evaluated on real images that had been captured from a commercial dual energy X-ray luggage inspection system. The obtained results show that the proposed algorithm is effective and operative in detection of the metallic, organic and mixed materials with acceptable accuracy.

  14. Energy loss and electron and x-ray emission of slow highly charged Arq+ ions in grazing incidence on an Al(111) surface

    Science.gov (United States)

    Luo, Xianwen; Hu, Bitao; Zhang, Chengjun; Wang, Jijin; Chen, Chunhua

    2010-05-01

    Within the framework of the classical over-barrier model, energy loss, electron emission, and x-ray emission of slow highly charged ion Arq+ grazing on the Al(111) single-crystal surface under various azimuthal angles have been studied. The enhancement of energy loss, potential electron emission yields, intensity of KL1 satellite lines, or x-ray yields for the Ar17+ ion grazing along low-index crystallographic directions was observed. The calculated energy-loss spectra of atomic projectiles Ar0 interacting with metallic surface agree reasonably well with experiment. The inner-shell filling contributions through the side feeding mechanism, Auger transitions, and the radiative decay process are discussed by analyzing the final charge-state distributions of the reflected ions, potential electron emission yields, and x-ray yields under different azimuthal angles.

  15. Laser-produced plasma (LPP) x-ray source with BaF2 and rare-earth targets for application in dual-energy subtraction angiography (DESA)

    Science.gov (United States)

    Krol, Andrzej; Kieffer, Jean-Claude; Jiang, Zhiming; Yu, Jianfan; Chamberlain, Charles C.; Bassano, Daniel A.; Gallant, Pascal

    1999-05-01

    A laser produced plasma (LPP) x-ray source utilizing ultra- fast laser was investigated in the context of its utility for dual energy subtraction angiography. Experiments were performed with a Table Top Terawatt (TTT) laser using BaF2 and rare-earth metal targets including La, Ce, Nd and Gd. The laser was operated in a single-pulse or in a dual pulse mode with surface power density in the 1018 - 1019 Wcm-2 range with pulse duration of 150 or 450 fs. Infrared and/or green beams were utilized. Hot electrons' temperature was in the 35 - 50 keV range. The obtained LPP x- ray spectra were comprised of a continuous bremsstrahlung component as well as discrete characteristic lines. The bremsstrahlung extended to high energies with no evident cutoff energy below 100 keV. Its shape was best described by exp(-E/kTe), where Te is the hot electron temperature. The overall efficiency was equal to approximately 9 X 10-4 for 450 fs pulse and approximately 6 X 10-4 for 150 fs pulses. The x-ray focal spot size was in the range 13 to 50 microns. We have found that the LPP x- ray source with BaF2 and rare-earth targets provide x-ray spectra that might be suitable for DESA.

  16. High-energy X-ray focusing and applications to pair distribution function investigation of Pt and Au nanoparticles at high pressures.

    Science.gov (United States)

    Hong, Xinguo; Ehm, Lars; Zhong, Zhong; Ghose, Sanjit; Duffy, Thomas S; Weidner, Donald J

    2016-02-23

    We report development of micro-focusing optics for high-energy x-rays by combining a sagittally bent Laue crystal monchromator with Kirkpatrick-Baez (K-B) X-ray focusing mirrors. The optical system is able to provide a clean, high-flux X-ray beam suitable for pair distribution function (PDF) measurements at high pressure using a diamond anvil cell (DAC). A focused beam of moderate size (10-15 μm) has been achieved at energies of 66 and 81 keV. PDF data for nanocrystalline platinum (n-Pt) were collected at 12.5 GPa with a single 5 s X-ray exposure, showing that the in-situ compression, decompression, and relaxation behavior of samples in the DAC can be investigated with this technique. PDFs of n-Pt and nano Au (n-Au) under quasi-hydrostatic loading to as high as 71 GPa indicate the existence of substantial reduction of grain or domain size for Pt and Au nanoparticles at pressures below 10 GPa. The coupling of sagittally bent Laue crystals with K-B mirrors provides a useful means to focus high-energy synchrotron X-rays from a bending magnet or wiggler source.

  17. Hand x-ray

    Science.gov (United States)

    X-ray - hand ... A hand x-ray is taken in a hospital radiology department or your health care provider's office by an ... technician. You will be asked to place your hand on the x-ray table, and keep it ...

  18. X-Ray

    Science.gov (United States)

    ... show up on chest X-rays. Breast cancer. Mammography is a special type of X-ray test used to examine breast tissue. Enlarged heart. This sign of congestive heart failure shows up clearly on X-rays. Blocked blood vessels. Injecting a contrast material that contains iodine can help highlight sections ...

  19. Analysis of Flow Cytometry DNA Damage Response Protein Activation Kinetics Following X-rays and High Energy Iron Nuclei Exposure

    Energy Technology Data Exchange (ETDEWEB)

    Universities Space Research Association; Chappell, Lori J.; Whalen, Mary K.; Gurai, Sheena; Ponomarev, Artem; Cucinotta, Francis A.; Pluth, Janice M.

    2010-12-15

    We developed a mathematical method to analyze flow cytometry data to describe the kinetics of {gamma}H2AX and pATF2 phosphorylations ensuing various qualities of low dose radiation in normal human fibroblast cells. Previously reported flow cytometry kinetic results for these DSB repair phospho-proteins revealed that distributions of intensity were highly skewed, severely limiting the detection of differences in the very low dose range. Distributional analysis reveals significant differences between control and low dose samples when distributions are compared using the Kolmogorov-Smirnov test. Radiation quality differences are found in the distribution shapes and when a nonlinear model is used to relate dose and time to the decay of the mean ratio of phosphoprotein intensities of irradiated samples to controls. We analyzed cell cycle phase and radiation quality dependent characteristic repair times and residual phospho-protein levels with these methods. Characteristic repair times for {gamma}H2AX were higher following Fe nuclei as compared to X-rays in G1 cells (4.5 {+-} 0.46 h vs 3.26 {+-} 0.76 h, respectively), and in S/G2 cells (5.51 {+-} 2.94 h vs 2.87 {+-} 0.45 h, respectively). The RBE in G1 cells for Fe nuclei relative to X-rays for {gamma}H2AX was 2.05 {+-} 0.61 and 5.02 {+-} 3.47, at 2 h and 24-h postirradiation, respectively. For pATF2, a saturation effect is observed with reduced expression at high doses, especially for Fe nuclei, with much slower characteristic repair times (>7 h) compared to X-rays. RBEs for pATF2 were 0.66 {+-} 0.13 and 1.66 {+-} 0.46 at 2 h and 24 h, respectively. Significant differences in {gamma}H2AX and pATF2 levels comparing irradiated samples to control were noted even at the lowest dose analyzed (0.05 Gy) using these methods of analysis. These results reveal that mathematical models can be applied to flow cytometry data to uncover important and subtle differences following exposure to various qualities of low dose radiation.

  20. Detectability comparison between a high energy x-ray phase sensitive and mammography systems in imaging phantoms with varying glandular-adipose ratios.

    Science.gov (United States)

    Ghani, Muhammad U; Wong, Molly D; Wu, Di; Zheng, Bin; Fajardo, Laurie L; Yan, Aimin; Fuh, Janis; Wu, Xizeng; Liu, Hong

    2017-05-07

    The objective of this study was to demonstrate the potential benefits of using high energy x-rays in comparison with the conventional mammography imaging systems for phase sensitive imaging of breast tissues with varying glandular-adipose ratios. This study employed two modular phantoms simulating the glandular (G) and adipose (A) breast tissue composition in 50 G-50 A and 70 G-30 A percentage densities. Each phantom had a thickness of 5 cm with a contrast detail test pattern embedded in the middle. For both phantoms, the phase contrast images were acquired using a micro-focus x-ray source operated at 120 kVp and 4.5 mAs, with a magnification factor (M) of 2.5 and a detector with a 50 µm pixel pitch. The mean glandular dose delivered to the 50 G-50 A and 70 G-30 A phantom sets were 1.33 and 1.3 mGy, respectively. A phase retrieval algorithm based on the phase attenuation duality that required only a single phase contrast image was applied. Conventional low energy mammography images were acquired using GE Senographe DS and Hologic Selenia systems utilizing their automatic exposure control (AEC) settings. In addition, the automatic contrast mode (CNT) was also used for the acquisition with the GE system. The AEC mode applied higher dose settings for the 70 G-30 A phantom set. As compared to the phase contrast images, the dose levels for the AEC mode acquired images were similar while the dose levels for the CNT mode were almost double. The observer study, contrast-to-noise ratio and figure of merit comparisons indicated a large improvement with the phase retrieved images in comparison to the AEC mode images acquired with the clinical systems for both density levels. As the glandular composition increased, the detectability of smaller discs decreased with the clinical systems, particularly with the GE system, even at higher dose settings. As compared to the CNT mode (double dose) images, the observer study also indicated that the phase retrieved images provided

  1. Detectability comparison between a high energy x-ray phase sensitive and mammography systems in imaging phantoms with varying glandular-adipose ratios

    Science.gov (United States)

    Ghani, Muhammad U.; Wong, Molly D.; Wu, Di; Zheng, Bin; Fajardo, Laurie L.; Yan, Aimin; Fuh, Janis; Wu, Xizeng; Liu, Hong

    2017-05-01

    The objective of this study was to demonstrate the potential benefits of using high energy x-rays in comparison with the conventional mammography imaging systems for phase sensitive imaging of breast tissues with varying glandular-adipose ratios. This study employed two modular phantoms simulating the glandular (G) and adipose (A) breast tissue composition in 50 G-50 A and 70 G-30 A percentage densities. Each phantom had a thickness of 5 cm with a contrast detail test pattern embedded in the middle. For both phantoms, the phase contrast images were acquired using a micro-focus x-ray source operated at 120 kVp and 4.5 mAs, with a magnification factor (M) of 2.5 and a detector with a 50 µm pixel pitch. The mean glandular dose delivered to the 50 G-50 A and 70 G-30 A phantom sets were 1.33 and 1.3 mGy, respectively. A phase retrieval algorithm based on the phase attenuation duality that required only a single phase contrast image was applied. Conventional low energy mammography images were acquired using GE Senographe DS and Hologic Selenia systems utilizing their automatic exposure control (AEC) settings. In addition, the automatic contrast mode (CNT) was also used for the acquisition with the GE system. The AEC mode applied higher dose settings for the 70 G-30 A phantom set. As compared to the phase contrast images, the dose levels for the AEC mode acquired images were similar while the dose levels for the CNT mode were almost double. The observer study, contrast-to-noise ratio and figure of merit comparisons indicated a large improvement with the phase retrieved images in comparison to the AEC mode images acquired with the clinical systems for both density levels. As the glandular composition increased, the detectability of smaller discs decreased with the clinical systems, particularly with the GE system, even at higher dose settings. As compared to the CNT mode (double dose) images, the observer study also indicated that the phase retrieved images provided

  2. Effect of high energy X-ray irradiation on the nano-mechanical properties of human enamel and dentine

    Directory of Open Access Journals (Sweden)

    Xue LIANG

    2016-01-01

    Full Text Available Abstract Radiotherapy for malignancies in the head and neck can cause common complications that can result in tooth damage that are also known as radiation caries. The aim of this study was to examine damage to the surface topography and calculate changes in friction behavior and the nano-mechanical properties (elastic modulus, nanohardness and friction coefficient of enamel and dentine from extracted human third molars caused by exposure to radiation. Enamel and dentine samples from 50 human third molars were randomly assigned to four test groups or a control group. The test groups were exposed to high energy X-rays at 2 Gy/day, 5 days/week for 5 days (10 Gy group, 15 days (30 Gy group, 25 days (50 Gy group, 35 days (70 Gy group; the control group was not exposed. The nanohardness, elastic modulus, and friction coefficient were analyzed using a Hysitron Triboindenter. The nano-mechanical properties of both enamel and dentine showed significant dose-response relationships. The nanohardness and elastic modulus were most variable between 30-50 Gy, while the friction coefficient was most variable between 0-10 Gy for dentine and 30-50 Gy for enamel. After exposure to X-rays, the fracture resistance of the teeth clearly decreased (rapidly increasing friction coefficient with increasing doses under the same load, and they were more fragile. These nano-mechanical changes in dental hard tissue may increase the susceptibility to caries. Radiotherapy caused nano-mechanical changes in dentine and enamel that were dose related. The key doses were 30-50 Gy and the key time points occurred during the 15th-25th days of treatment, which is when application of measures to prevent radiation caries should be considered.

  3. Effect of high energy X-ray irradiation on the nano-mechanical properties of human enamel and dentine

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Xue; Zhang, Jing Yang; Cheng, Iek Ka [State Key Laboratory of Oral Diseases, Sichuan University, Chengdu (China); Li, Ji Yao, E-mail: jiyao_li@aliyun.com [West China School of Stomatology, Sichuan University, Chengdu (China)

    2016-05-01

    Radiotherapy for malignancies in the head and neck can cause common complications that can result in tooth damage that are also known as radiation caries. The aim of this study was to examine damage to the surface topography and calculate changes in friction behavior and the nano-mechanical properties (elastic modulus, nano hardness and friction coefficient) of enamel and dentine from extracted human third molars caused by exposure to radiation. Enamel and dentine samples from 50 human third molars were randomly assigned to four test groups or a control group. The test groups were exposed to high energy X-rays at 2 Gy/day, 5 days/week for 5 days (10 Gy group), 15 days (30 Gy group), 25 days (50 Gy group), 35 days (70 Gy group); the control group was not exposed. The nano hardness, elastic modulus, and friction coefficient were analyzed using a Hysitron Triboindenter. The nano-mechanical properties of both enamel and dentine showed significant dose-response relationships. The nano hardness and elastic modulus were most variable between 30-50 Gy, while the friction coefficient was most variable between 0-10 Gy for dentine and 30-50 Gy for enamel. After exposure to X-rays, the fracture resistance of the teeth clearly decreased (rapidly increasing friction coefficient with increasing doses under the same load), and they were more fragile. These nano-mechanical changes in dental hard tissue may increase the susceptibility to caries. Radiotherapy caused nano-mechanical changes in dentine and enamel that were dose related. The key doses were 30-50 Gy and the key time points occurred during the 15{sup th}-25{sup th} days of treatment, which is when application of measures to prevent radiation caries should be considered. (author)

  4. X-ray spectrometry using polycapillary X-ray optics and position sensitive detector.

    Science.gov (United States)

    Ding, X; Xie, J; He, Y; Pan, Q; Yan, Y

    2000-10-02

    Polycapillary X-ray optics (capillary X-ray lens) are now popular in X-ray fluorescence (XRF) analysis. Such an X-ray lens can collect X-rays emitted from an X-ray source in a large solid angle and form a very intense X-ray microbeam which is very convenient for microbeam X-ray fluorescence (MXRF) analysis giving low minimum detection limits (MDLs) in energy dispersive X-ray fluorescence (EDXRF). A new method called position sensitive X-ray spectrometry (PSXS) which combines an X-ray lens used to form an intense XRF source and a position sensitive detector (PSD) used for wavelength dispersive spectrometry (WDS) measurement was developed recently in the X-ray Optics Laboratory of Institute of Low Energy Nuclear Physics (ILENP) at Beijing Normal University. Such a method can give high energy and spacial resolution and high detection efficiency simultaneously. A short view of development of both the EDXRF using a capillary X-ray lens and the new PSXS is given in this paper.

  5. On amplitude beam splitting of tender X-rays (2-8 keV photon energy) using conical diffraction from reflection gratings with laminar profile.

    Science.gov (United States)

    Jark, Werner; Eichert, Diane

    2016-01-01

    Conical diffraction is obtained when a radiation beam impinges onto a periodically ruled surface structure parallel or almost parallel to the ruling. In this condition the incident intensity is diffracted through an arc, away from the plane of incidence. The diffracted intensity thus lies on a cone, which leads to the name `conical diffraction'. In this configuration almost no part of the ruled structure will produce any shadowing effect for the incident or the diffracted beam. Then, compared with a grating in the classical orientation, relatively higher diffraction efficiencies will be observed for fewer diffraction orders. When the incident beam is perfectly parallel to the grooves of a rectangular grating profile, the symmetry of the setup causes diffraction of the intensity symmetrically around the plane of incidence. This situation was previously tested experimentally in the VUV spectral range for the amplitude beam splitting of a radiation beam with a photon energy of 25 eV. In this case the ideally expected beam splitting efficiency of about 80% for the diffraction into the two first orders was confirmed for the optimum combination of groove depth and angle of grazing incidence. The feasibility of the amplitude beam splitting for hard X-rays with 12 keV photon energy by use of the same concept was theoretically confirmed. However, no related experimental data are presented yet, not even for lower energy soft X-rays. The present study reports the first experimental data for the conical diffraction from a rectangular grating profile in the tender X-ray range for photon energies of 4 keV and 6 keV. The expected symmetries are observed. The maximum absolute efficiency for beam splitting was measured to be only about 30%. As the reflectivity of the grating coating at the corresponding angle of grazing incidence was found to be only of the order of 50%, the relative beam splitting efficiency was thus 60%. This is to be compared also here with an ideally

  6. New Constraints on Dark Energy from Chandra X-rayObservations of the Largest Relaxed Galaxy Clusters

    Energy Technology Data Exchange (ETDEWEB)

    Allen, S.W.; Rapetti, D.A.; /KIPAC, Menlo Park; Schmidt, R.W.; /Heidelberg, Astron. Rechen Inst.; Ebeling, H.; /Inst. Astron., Honolulu; Morris, G.; /KIPAC, Menlo Park; Fabian, A.C.; /Cambridge U., Inst. of Astron.

    2007-06-06

    We present constraints on the mean matter density, {Omega}{sub m}, dark energy density, {Omega}{sub DE}, and the dark energy equation of state parameter, w, using Chandra measurements of the X-ray gas mass fraction (fgas) in 42 hot (kT > 5keV), X-ray luminous, dynamically relaxed galaxy clusters spanning the redshift range 0.05 < z < 1.1. Using only the fgas data for the 6 lowest redshift clusters at z < 0.15, for which dark energy has a negligible effect on the measurements, we measure {Omega}{sub m}=0.28{+-}0.06 (68% confidence, using standard priors on the Hubble Constant, H{sub 0}, and mean baryon density, {Omega}{sub b}h{sup 2}). Analyzing the data for all 42 clusters, employing only weak priors on H{sub 0} and {Omega}{sub b}h{sup 2}, we obtain a similar result on {Omega}{sub m} and detect the effects of dark energy on the distances to the clusters at {approx}99.99% confidence, with {Omega}{sub DE}=0.86{+-}0.21 for a non-flat LCDM model. The detection of dark energy is comparable in significance to recent SNIa studies and represents strong, independent evidence for cosmic acceleration. Systematic scatter remains undetected in the f{sub gas} data, despite a weighted mean statistical scatter in the distance measurements of only {approx}5%. For a flat cosmology with constant w, we measure {Omega}{sub m}=0.28{+-}0.06 and w=-1.14{+-}0.31. Combining the fgas data with independent constraints from CMB and SNIa studies removes the need for priors on {Omega}{sub b}h{sup 2} and H{sub 0} and leads to tighter constraints: {Omega}{sub m}=0.253{+-}0.021 and w=-0.98{+-}0.07 for the same constant-w model. More general analyses in which we relax the assumption of flatness and/or allow evolution in w remain consistent with the cosmological constant paradigm. Our analysis includes conservative allowances for systematic uncertainties. The small systematic scatter and tight constraints bode well for future dark energy studies using the f{sub gas} method.

  7. Design of a nondestructive two-in-one instrument for measuring the polarization and energy spectrum at an X-ray FEL facility

    Science.gov (United States)

    Zhang, Qingmin; Deng, Bangjie; Chen, Yuanmiaoliang; Liu, Bochao; Chen, Shaofei; Fan, Jinquan; Feng, Lie; Deng, Haixiao; Liu, Bo; Wang, Dong

    2017-10-01

    The free electron laser (FEL), as a next-generation light source, is an attractive tool in scientific frontier research because of its advantages of full coherence, ultra-short pulse duration, and controllable polarization. Owing to the demand of real-time bunch diagnosis during FEL experiments, precise nondestructive measurements of the polarization and X-ray energy spectrum using one instrument are preferred. In this paper, such an instrument based on the electron time-of-flight technique is proposed. By considering the complexity and nonlinearity, a numerical model in the framework of Geant4 has been developed for optimization. Taking the Shanghai Soft X-ray FEL user facility as an example, its measurement performances' dependence on the critical parameters was studied systematically, and, finally, an optimal design was obtained, achieving resolutions of 0.5% for the polarization degree and 0.3 eV for the X-ray energy spectrum.

  8. The Energy-Dependent X-Ray Timing Characteristics of the Narrow Line Seyfert 1 MKN 766

    Science.gov (United States)

    Markowitz, A.; Papadakis, I.; Arevalo, P.; Turner, T. J.; Miller, L.; Reeves, J. N.

    2007-01-01

    We present the energy-dependent power spectral density (PSD) and cross-spectral properties of Mkn 766, obtained from combining data obtained during an XMM-Newton observation spanning six revolutions in 2005 with data obtained from an XMM-Newton long-look in 2001. The PSD shapes and rms-flux relations are found to be consistent between the 2001 and 2005 observations, suggesting the 2005 observation is simply a low-flux extension of the 2001 observation and permitting us to combine the two data sets. The resulting PSD has the highest temporal frequency resolution for any AGN PSD measured to date. Applying a broken power-law model yields break frequencies which increase in temporal frequency with photon energy. Obtaining a good fit when assuming energy-independent break frequencies requires the presence of a Lorentzian at 4.6 +/- 0.4 x 10(exp -4)Hz whose strength increases with photon energy, a behavior seen in black hole X-ray binaries. The cross-spectral properties are measured; temporal frequency-dependent soft-to-hard time lags are detected in this object for the first time. Cross-spectral results are consistent with those for other accreting black hole systems. The results are discussed in the context of several variability models, including those based on inwardly-propagating viscosity variations in the accretion disk.

  9. Model-Based Iterative Reconstruction for Dual-Energy X-Ray CT Using a Joint Quadratic Likelihood Model.

    Science.gov (United States)

    Zhang, Ruoqiao; Thibault, Jean-Baptiste; Bouman, Charles A; Sauer, Ken D; Hsieh, Jiang

    2014-01-01

    Dual-energy X-ray CT (DECT) has the potential to improve contrast and reduce artifacts as compared to traditional CT. Moreover, by applying model-based iterative reconstruction (MBIR) to dual-energy data, one might also expect to reduce noise and improve resolution. However, the direct implementation of dual-energy MBIR requires the use of a nonlinear forward model, which increases both complexity and computation. Alternatively, simplified forward models have been used which treat the material-decomposed channels separately, but these approaches do not fully account for the statistical dependencies in the channels. In this paper, we present a method for joint dual-energy MBIR (JDE-MBIR), which simplifies the forward model while still accounting for the complete statistical dependency in the material-decomposed sinogram components. The JDE-MBIR approach works by using a quadratic approximation to the polychromatic log-likelihood and a simple but exact nonnegativity constraint in the image domain. We demonstrate that our method is particularly effective when the DECT system uses fast kVp switching, since in this case the model accounts for the inaccuracy of interpolated sinogram entries. Both phantom and clinical results show that the proposed model produces images that compare favorably in quality to previous decomposition-based methods, including FBP and other statistical iterative approaches.

  10. The energy budget for X-ray to infrared reprocessing in Compton-thin and Compton-thick active galaxies

    OpenAIRE

    Yaqoob, Tahir; Murphy, Kendrah D.

    2010-01-01

    Heavily obscured active galactic nuclei (AGNs) play an important role in contributing to the cosmic X-ray background (CXRB). However, the AGNs found in deep X-ray surveys are often too weak to allow direct measurement of the column density of obscuring matter. One method adopted in recent years to identify heavily obscured, Compton-thick AGNs under such circumstances is to use the observed mid-infrared to X-ray luminosity ratio as a proxy for the column density. This is based on the suppositi...

  11. Mineralogy of the clay fraction of soils from the moray cusco archaeological site: a study by energy dispersive X-ray fluorescence, X-ray diffractometry and Moessbauer spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ceron Loayza, Maria L., E-mail: malucelo@hotmail.com; Bravo Cabrejos, Jorge A.; Mejia Santillan, Mirian E. [Universidad Nacional Mayor de San Marcos, Laboratorio de Analisis de Suelos, Laboratorio de Espectroscopia Moessbauer, Facultad de Ciencias Fisicas (Peru)

    2011-11-15

    The purpose of this work is to report the advances in the elemental and structural characterization of the clay fraction of soils from the terraces of the Moray Archaeological site, located 38 km north of the city of Cusco, Cusco Region. One sample was collected from each of the twelve terraces of this site and its clay fraction was separated by sedimentation. Previously the pH of the raw samples was measured resulting that all of the samples were from alkaline to strongly alkaline. Energy dispersive X-ray fluorescence (EDXRF) was used for the elemental characterization, and X-ray diffractometry (XRD) and transmission Moessbauer spectroscopy (TMS), using the {gamma} 14.4 keV nuclear resonance transition in {sup 57}Fe, were used for the structural characterization of the clays and clay minerals present in each sample. The EDXRF analyses of all the samples show the presence of relatively high concentrations of sulfur in some of the samples and relatively high concentrations of calcium in all of the samples, which may be related to the high alkalinity of the samples. By XRD it is observed the presence of quartz, calcite, gypsum, cronstedtite, 2:1 phyllosilicates, and iron oxides. The mineralogical analysis of Fe by TMS shows that it is present in the form of hematite and occupying Fe{sup 2 + } and Fe{sup 3 + } sites in phyllosilicates, cronstedtite, and other minerals not yet identified.

  12. New pathways for improved quantification of energy-dispersive X-ray spectra of semiconductors with multiple X-ray lines from thin foils investigated in transmission electron microscopy.

    Science.gov (United States)

    Parri, M C; Qiu, Y; Walther, T

    2015-12-01

    Theoretical approaches to quantify the chemical composition of bulk and thin-layer specimens using energy-dispersive X-ray spectroscopy in a transmission electron microscope are compared to experiments investigating (In)GaAs and Si(Ge) semiconductors. Absorption correctors can be improved by varying the take-off angle to determine the depth of features within the foil or the samples thickness, or by definition of effective k-factors that can be obtained from plots of k-factors versus foil thickness or, preferably, versus the K/L intensity ratio for a suitable element. The latter procedure yields plots of self-consistent absorption corrections that can be used to determine the chemical composition, iteratively for SiGe using a set of calibration curves or directly from a single calibration curve for InGaAs, for single X-ray spectra without knowledge of sample thickness, density or mass absorption coefficients. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  13. Debris of potassium–magnesium silicate glass generated by femtosecond laser-induced ablation in air: An analysis by near edge X-ray absorption spectroscopy, micro Raman and energy dispersive X-ray spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Grehn, M., E-mail: grehn@physik.tu-berlin.de [Technische Universität Berlin, Institut für Optik und Atomare Physik, Straße des 17. Juni 135, 10623 Berlin (Germany); Seuthe, T. [Fraunhofer-Institut für Keramische Technologien und Systeme (IKTS), Winterbergstraße 28, 01277 Dresden (Germany); Reinhardt, F. [Physikalisch-Technische Bundesanstalt (PTB), Albert-Einstein-Straße 15, 12489 Berlin (Germany); Höfner, M.; Griga, N. [Technische Universität Berlin, Institut für Optik und Atomare Physik, Straße des 17. Juni 135, 10623 Berlin (Germany); Eberstein, M. [Fraunhofer-Institut für Keramische Technologien und Systeme (IKTS), Winterbergstraße 28, 01277 Dresden (Germany); Bonse, J. [BAM Bundesanstalt für Materialforschung und –prüfung, Unter den Eichen 87, 12205 Berlin (Germany)

    2014-05-01

    The redeposited material (debris) resulting from ablation of a potassium–magnesium silicate glass upon scanning femtosecond laser pulse irradiation (130 fs, 800 nm) in air environment is investigated by means of three complementary surface analytical methods. Changes in the electronic band structure of the glass constituent Magnesium (Mg) were identified by X-ray Absorption Near Edge Structure spectroscopy (XANES) using synchrotron radiation. An up-shift of ≈0.8 eV of a specific Magnesium K-edge absorption peak in the spectrum of the redeposited material along with a significant change in its leading edge position was detected. In contrast, the surface left after laser ablation exhibits a downshift of the peak position by ≈0.9 eV. Both observations may be related to a change of the Mg coordinative state of the laser modified/redeposited glass material. The presence of carbon in the debris is revealed by micro Raman spectroscopy (μ-RS) and was confirmed by energy dispersive X-ray spectroscopy (EDX). These observations are attributed to structural changes and chemical reactions taking place during the ablation process.

  14. Solid state synthesis of layered sodium manganese oxide for sodium-ion battery by in-situ high energy X-ray diffraction and X-ray absorption near edge spectroscopy

    Science.gov (United States)

    Ma, Tianyuan; Xu, Gui-Liang; Zeng, Xiaoqiao; Li, Yan; Ren, Yang; Sun, Chengjun; Heald, Steve M.; Jorne, Jacob; Amine, Khalil; Chen, Zonghai

    2017-02-01

    In situ high energy X-ray diffraction (HEXRD) and in situ X-ray absorption near edge spectroscopy (XANES) were carried out to understand the solid state synthesis of NaxMnO2, with particular interest on the synthesis of P2 type Na2/3MnO2. It was found that there were multi intermediate phases formed before NaMnO2 appeared at about 600 °C. And the final product after cooling process is a combination of O‧3 NaMnO2 with P2 Na2/3MnO2. A P2 type Na2/3MnO2 was synthesized at reduced temperature (600 °C). The influence of Na2CO3 impurity on the electrochemical performance of P2 Na2/3MnO2 was thoroughly investigated in our work. It was found that the content of Na2CO3 can be reduced by optimizing Na2CO3/MnCO3 ratio during the solid state reaction or other post treatment such as washing with water. We expected our results could provide a good guide for future development of high performance cathode materials for sodium-ion batteries.

  15. Mineralogy of the clay fraction of soils from the moray cusco archaeological site: a study by energy dispersive X-ray fluorescence, X-ray diffractometry and Mössbauer spectroscopy

    Science.gov (United States)

    Cerón Loayza, María L.; Bravo Cabrejos, Jorge A.; Mejía Santillán, Mirian E.

    2011-11-01

    The purpose of this work is to report the advances in the elemental and structural characterization of the clay fraction of soils from the terraces of the Moray Archaeological site, located 38 km north of the city of Cusco, Cusco Region. One sample was collected from each of the twelve terraces of this site and its clay fraction was separated by sedimentation. Previously the pH of the raw samples was measured resulting that all of the samples were from alkaline to strongly alkaline. Energy dispersive X-ray fluorescence (EDXRF) was used for the elemental characterization, and X-ray diffractometry (XRD) and transmission Mössbauer spectroscopy (TMS), using the γ 14.4 keV nuclear resonance transition in 57Fe, were used for the structural characterization of the clays and clay minerals present in each sample. The EDXRF analyses of all the samples show the presence of relatively high concentrations of sulfur in some of the samples and relatively high concentrations of calcium in all of the samples, which may be related to the high alkalinity of the samples. By XRD it is observed the presence of quartz, calcite, gypsum, cronstedtite, 2:1 phyllosilicates, and iron oxides. The mineralogical analysis of Fe by TMS shows that it is present in the form of hematite and occupying Fe2 + and Fe3 + sites in phyllosilicates, cronstedtite, and other minerals not yet identified.

  16. A Suzaku Search for Nonthermal Emission at Hard X-Ray Energies in the Coma Cluster

    Science.gov (United States)

    2008-09-01

    probes may be compromised ( Skillman et al. 2008). An assessment of the relativistic contribution to the energy budget of clusters is necessary to...thesis, University of Maryland Skillman , S. W., O’Shea, B. W., Hallman, E. J., Burns, J. O., & Norman, M. L. 2008, ApJ, 689, 1063 Snowden, S. L., & Kuntz

  17. Solar X-ray Spectrometer (SOXS) Mission–Low Energy Payload ...

    Indian Academy of Sciences (India)

    The SOXS Low Energy Detector (SLD) payload was designed, developed and fabricated by Physical Research Laboratory (PRL) in collaboration with Space Application Centre (SAC), Ahmedabad and ISRO Satellite Centre (ISAC), Bangalore of the Indian Space Research Organization (ISRO). The SLD payload employs ...

  18. A graded d-spacing multilayer telescope for high-energy x-ray astronomy

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Hornstrup, Allan; WESTERGAARD, NJ

    1992-01-01

    A high energy telescope design is presented which combines grazing incidence geometry with Bragg reflection in a graded d-spacing multilayer coating to obtain significant sensitivity up to --6O keV. The concept utilizes total reflection and first order Bragg reflection in a graded d-spacing multi...

  19. Measurement of photoneutron doses in and out of high-energy X-ray beam of a SATURNE-20 medical linear accelerator by ECE polycarbonate detectors

    CERN Document Server

    Sohrabi, M

    1999-01-01

    Photoneutron contaminations in and out of high energy X-ray beams of the medical linear accelerator SATURNE 20 (CGR) of the Radiotherapy Department of Omeed Hospital in Isfahan, Iran, have been determined using 250 mu m polycarbonate (PC) dosimeters, in strips or in sheets, processed by electrochemical etching (ECE) using specially designed ECE chambers to etch larger sheets. A two dimensional or topographical distribution of neutron contamination was also determined in a full size beam. The neutron dose equivalents (Hn) in the beam of 18 MV X-rays at 80 cm FSD were determined to be linear functions of X-ray dose equivalents (Hx) up to 1400 cSv. The distribution of the Hn at different X-ray doses showed bell-shape profiles with maxima at the isocenter. The ratios of dose equivalents of neutrons to those of X-rays increased as the field size increased having values of 0.22%, 0.28%, 0.31% and 0.37% for field sizes of 10x10, 20x20, 30x30, and 40x40 cm sup 2 respectively. Although such neutron dose equivalents ca...

  20. Monitoring the 2010-2015 Hard X-ray/Low-Energy Gamma-Ray Activity of Cygnus X-1 with GBM

    Science.gov (United States)

    Case, Gary L.; Jenke, Peter; Wilson-Hodge, Colleen A.

    2017-08-01

    Cygnus X-1 is a high-mass X-ray binary with a black hole companion that typically resides in a hard spectral state, where it is extremely bright in hard X-rays and low energy gamma rays and much fainter in the soft X-rays. Since 2008 August, we have used the Gamma-Ray Burst Monitor (GBM) on Fermi to monitor Cyg X-1 in the 10-1000 keV energy range using the Earth occultation technique. Starting in the middle of 2010, Cyg X-1 was observed by GBM to enter a period of increased activity, making several transitions to the soft state, characterized by the typical rise in the soft X-ray flux and decrease in the hard x-ray and low energy gamma-ray flux. From the soft state, Cyg X-1 made several transitions to intermediate states as well as several short transitions back to the hard state. At the end of 2015, Cyg X-1 transitioned back to the canonical hard state, where it has remained ever since. We have generated long-term, broad-band light curves based on daily monitoring of Cyg X-1 over a 9 year period showing the hard-to-soft state transitions, the intermediate states, and the soft-to-hard and failed soft-to-hard state transitions. Spectra are presented of Cyg X-1 in the various states and comparisons made between spectra in the same state. The time evolution of the x-ray hardness ratios is also presented.

  1. NuSTAR detection of high-energy X-ray emission and rapid variability from Sagittarius A{sup *} flares

    Energy Technology Data Exchange (ETDEWEB)

    Barrière, Nicolas M.; Tomsick, John A.; Boggs, Steven E.; Craig, William W.; Zoglauer, Andreas [Space Sciences Laboratory, University of California, Berkeley, CA 94720 (United States); Baganoff, Frederick K. [Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, Cambridge, MA 02139-4307 (United States); Christensen, Finn E. [DTU Space, National Space Institute, Technical University of Denmark, Elektrovej 327, DK-2800 Kgs. Lyngby (Denmark); Dexter, Jason [Departments of Physics and Astronomy, University of California, Berkeley, CA 94720 (United States); Grefenstette, Brian; Harrison, Fiona A.; Madsen, Kristin K. [Cahill Center for Astronomy and Astrophysics, Caltech, Pasadena, CA 91125 (United States); Hailey, Charles J.; Mori, Kaya; Zhang, Shuo [Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Stern, Daniel [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Zhang, William W. [X-ray Astrophysics Laboratory, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

    2014-05-01

    Sagittarius A{sup *} harbors the supermassive black hole that lies at the dynamical center of our Galaxy. Sagittarius A{sup *} spends most of its time in a low luminosity emission state but flares frequently in the infrared and X-ray, increasing up to a few hundred fold in brightness for up to a few hours at a time. The physical processes giving rise to the X-ray flares are uncertain. Here we report the detection with the NuSTAR observatory in Summer and Fall 2012 of four low to medium amplitude X-ray flares to energies up to 79 keV. For the first time, we clearly see that the power-law spectrum of Sagittarius A{sup *} X-ray flares extends to high energy, with no evidence for a cutoff. Although the photon index of the absorbed power-law fits are in agreement with past observations, we find a difference between the photon index of two of the flares (significant at the 95% confidence level). The spectra of the two brightest flares (∼55 times quiescence in the 2-10 keV band) are compared to simple physical models in an attempt to identify the main X-ray emission mechanism, but the data do not allow us to significantly discriminate between them. However, we confirm the previous finding that the parameters obtained with synchrotron models are, for the X-ray emission, physically more reasonable than those obtained with inverse Compton models. One flare exhibits large and rapid (<100 s) variability, which, considering the total energy radiated, constrains the location of the flaring region to be within ∼10 Schwarzschild radii of the black hole.

  2. NuSTAR Detection of High-Energy X-Ray Emission and Rapid Variability from Sagittarius A(star) Flares

    Science.gov (United States)

    Barriere, Nicolas M.; Tomsick, John A.; Baganoff, Frederick K.; Boggs, Steven E.; Christensen, Finn E.; Craig, William W.; Dexter, Jason; Grefenstette, Brian; Hailey, Charles J.; Zhang, William W.

    2014-01-01

    Sagittarius A(star) harbors the supermassive black hole that lies at the dynamical center of our Galaxy. Sagittarius A(star) spends most of its time in a low luminosity emission state but flares frequently in the infrared and X-ray, increasing up to a few hundred fold in brightness for up to a few hours at a time. The physical processes giving rise to the X-ray flares are uncertain. Here we report the detection with the NuSTAR observatory in Summer and Fall 2012 of four low to medium amplitude X-ray flares to energies up to 79 keV. For the first time, we clearly see that the power-law spectrum of Sagittarius A(star) X-ray flares extends to high energy, with no evidence for a cut off. Although the photon index of the absorbed power-law fits are in agreement with past observations, we find a difference between the photon index of two of the flares (significant at the 95% confidence level). The spectra of the two brightest flares (approx. 55 times quiescence in the 2- 10 keV band) are compared to simple physical models in an attempt to identify the main X-ray emission mechanism, but the data do not allow us to significantly discriminate between them. However, we confirm the previous finding that the parameters obtained with synchrotron models are, for the X-ray emission, physically more reasonable than those obtained with inverse-Compton models. One flare exhibits large and rapid (less than 100 s) variability, which, considering the total energy radiated, constrains the location of the flaring region to be within approx. 10 Schwarzschild radii of the black hole.

  3. Earth Occultation Monitoring of the Hard X-ray/Low-Energy Gamma Ray Sky with GBM

    Science.gov (United States)

    Cherry, Michael L.; Camero-Arranz, A.; Case, G. L.; Chaplin, V.; Finger, M. H.; Jenke, P. A.; Rodi, J. C.; Wilson-Hodge, C. A.; GBM Earth Occultation Team

    2012-01-01

    By utilizing the Earth occultation technique (EOT), the Gamma-Ray Burst Monitor (GBM) instrument aboard Fermi has been used to make nearly continuous full-sky observations in the 8-1000 keV energy range. The GBM EOT analysis program currently monitors an input catalog containing 235 sources. We will present the GBM catalog of sources observed in the first 3 years of the EOT monitoring program, with special emphasis on the high energy (>100 keV) and time-variable sources, in particular the Crab, Cyg X-1, and A0535+26. We will also describe the initial results of an all-sky imaging analysis of the EOT data, with comparisons to the Swift, INTEGRAL, and Fermi LAT catalogs. This work is supported by the NASA Fermi Guest Investigator program, NASA/Louisiana Board of Regents, and Spanish Ministerio de Ciencia de Innovacion.

  4. Mesoscale structural characterization within bulk materials by high-energy X-ray microdiffraction

    DEFF Research Database (Denmark)

    Lienert, U.; Poulsen, H.F.; Kvick, Å.

    2001-01-01

    A novel diffraction technique for the local three-dimensional characterization within polycrystalline bulk materials is presented. The technique uses high-energy synchrotron radiation (40 keV ... that provide the required intensity and spatial resolution perpendicular to the incident beam. A focus size of 1.2 mum was achieved. Modified crossed-beam techniques are being developed that define the longitudinal resolution, i.e., the component of the gauge volume parallel to the incident beam. We present...

  5. A new method for polychromatic X-ray μLaue diffraction on a Cu pillar using an energy-dispersive pn-junction charge-coupled device.

    Science.gov (United States)

    Abboud, A; Kirchlechner, C; Send, S; Micha, J S; Ulrich, O; Pashniak, N; Strüder, L; Keckes, J; Pietsch, U

    2014-11-01

    μLaue diffraction with a polychromatic X-ray beam can be used to measure strain fields and crystal orientations of micro crystals. The hydrostatic strain tensor can be obtained once the energy profile of the reflections is measured. However, this remains a challenge both on the time scale and reproducibility of the beam position on the sample. In this review, we present a new approach to obtain the spatial and energy profiles of Laue spots by using a pn-junction charge-coupled device, an energy-dispersive area detector providing 3D resolution of incident X-rays. The morphology and energetic structure of various Bragg peaks from a single crystalline Cu micro-cantilever used as a test system were simultaneously acquired. The method facilitates the determination of the Laue spots' energy spectra without filtering the white X-ray beam. The synchrotron experiment was performed at the BM32 beamline of ESRF using polychromatic X-rays in the energy range between 5 and 25 keV and a beam size of 0.5 μm × 0.5 μm. The feasibility test on the well known system demonstrates the capabilities of the approach and introduces the "3D detector method" as a promising tool for material investigations to separate bending and strain for technical materials.

  6. A new method for polychromatic X-ray μLaue diffraction on a Cu pillar using an energy-dispersive pn-junction charge-coupled device

    Science.gov (United States)

    Abboud, A.; Kirchlechner, C.; Send, S.; Micha, J. S.; Ulrich, O.; Pashniak, N.; Strüder, L.; Keckes, J.; Pietsch, U.

    2014-11-01

    μLaue diffraction with a polychromatic X-ray beam can be used to measure strain fields and crystal orientations of micro crystals. The hydrostatic strain tensor can be obtained once the energy profile of the reflections is measured. However, this remains a challenge both on the time scale and reproducibility of the beam position on the sample. In this review, we present a new approach to obtain the spatial and energy profiles of Laue spots by using a pn-junction charge-coupled device, an energy-dispersive area detector providing 3D resolution of incident X-rays. The morphology and energetic structure of various Bragg peaks from a single crystalline Cu micro-cantilever used as a test system were simultaneously acquired. The method facilitates the determination of the Laue spots' energy spectra without filtering the white X-ray beam. The synchrotron experiment was performed at the BM32 beamline of ESRF using polychromatic X-rays in the energy range between 5 and 25 keV and a beam size of 0.5 μm × 0.5 μm. The feasibility test on the well known system demonstrates the capabilities of the approach and introduces the "3D detector method" as a promising tool for material investigations to separate bending and strain for technical materials.

  7. Energy-dispersive X-ray fluorescence study of elemental uptake in ...

    Indian Academy of Sciences (India)

    in root soils of MSW-contaminated farms are higher by almost an order of magnitude compared to uncontaminated farms. ... mators made of Bi, Cu and Al were placed at both the entrance and the exit ports of the sample holder. .... cauliflower root soil samples of the two sites and enhanced presence of toxic elements in.

  8. High-energy observations of the state transition of the X-ray nova and black hole candidate XTE J1720-318

    DEFF Research Database (Denmark)

    Bel, M.C.; Rodriguez, J.; Sizun, P.

    2004-01-01

    We report the results of extensive high-energy observations of the X-ray transient and black hole candidate XTE J1720-318 performed with INTEGRAL, XMM-Newton and RXTE. The source, which underwent an X-ray outburst in 2003 January, was observed in February in a spectral state dominated by a soft......, typical of a black-hole binary in the so-called High/Soft State. We then followed the evolution of the source outburst over several months using the INTEGRAL Galactic Centre survey observations. The source became active again at the end of March: it showed a clear transition towards a much harder state...... of the black hole X-ray novae class which populate our galactic bulge and we discuss its properties in the frame of the spectral models used for transient black hole binaries....

  9. High Energy Laboratory Astrophysics using an X-Ray Microcalorimeter with an Electron Beam Ion Trap Project

    Data.gov (United States)

    National Aeronautics and Space Administration — "Since the summer of 2000 we have successfully deployed a high resolution x-ray microcalorimeter spectrometer, based on the spaceflight XRS instrument, at the...

  10. Low-energy X-ray line emission from IC 443

    Science.gov (United States)

    Charles, P. A.; Kahn, S. M.; Mason, K. O.; Tuohy, I. R.

    1981-01-01

    HEAO 1 observations of the spectrum of the supernova remnant IC 443 in the energy range of 0.4-3 keV reveal the presence of a complex structure suggestive of emission from Fe XVIII-XX, S XV-XVI, and Si XIII-XIV ions. The best electron temperature in the band for simple model fits is about (6-11) x 10 to the 6th K. Raymond and Smith collisional equilibrium emission models do not adequately fit the data. These results are discussed in terms of possible nonequilibrium effects in the remnant.

  11. A deep learning framework for the automated inspection of complex dual-energy x-ray cargo imagery

    Science.gov (United States)

    Rogers, Thomas W.; Jaccard, Nicolas; Griffin, Lewis D.

    2017-05-01

    Previously, we investigated the use of Convolutional Neural Networks (CNNs) to detect so-called Small Metallic Threats (SMTs) hidden amongst legitimate goods inside a cargo container. We trained a CNN from scratch on data produced by a Threat Image Projection (TIP) framework that generates images with realistic variation to robustify performance. The system achieved 90% detection of containers that contained a single SMT, while raising 6% false positives on benign containers. The best CNN architecture used the raw high energy image (single-energy) and its logarithm as input channels. Use of the logarithm improved performance, thus echoing studies on human operator performance. However, it is an unexpected result with CNNs. In this work, we (i) investigate methods to exploit material information captured in dual-energy images, and (ii) introduce a new CNN training scheme that generates `spot-the-difference' benign and threat pairs on-the-fly. To the best of our knowledge, this is the first time that CNNs have been applied directly to raw dual-energy X-ray imagery, in any field. To exploit dual-energy, we experiment with adapting several physics-derived approaches to material discrimination from the cargo literature, and introduce three novel variants. We hypothesise that CNNs can implicitly learn about the material characteristics of objects from the raw dual-energy images, and use this to suppress false positives. The best performing method is able to detect 95% of containers containing a single SMT, while raising 0.4% false positives on benign containers. This is a step change improvement in performance over our prior work

  12. Phalangeal densitometry compared with dual energy X-ray absorptiometry for assessment of bone mineral density in elderly women.

    Science.gov (United States)

    Dhainaut, Alvilde; Rohde, Gudrun; Hoff, Mari; Syversen, Unni; Haugeberg, Glenn

    2011-12-01

    Reduced bone mineral density (BMD) is identified as a major risk factor for fracture. The World Health Organization criterion for diagnosis of osteoporosis (T-score ≤-2.5 SD) is based on dual energy X-ray absorptiometry (DXA) measurements. However DXA availability may be limited in some regions. In this study the ability of the phalangeal radiographic absorptiometry (RA) device, MetriScan, to identify women with reduced BMD at the femoral neck assessed by DXA was evaluated. The study population contained women with recent low-energy distal radius fracture and women recruited from the general population, all aged ≥50 years. A triage approach was applied in which two cut-offs for RA T-score were defined at which individuals with 90% sensitivity and 90% specificity could be identified to have or not have reduced BMD at the femoral neck defined as T-score ≤-2.5 SD. The correlation between phalangeal RA BMD and femoral neck DXA BMD was r=0.65 (passessment to determine if the femoral neck T-score is below or above -2.5 SD. The application of the RA MetriScan device can reduce the number of DXA assessments needed to detect reduced BMD. The device may thus be of clinical value if access to DXA is limited, as well as for screening purposes.

  13. Misfit strain of oxygen precipitates in Czochralski silicon studied with energy-dispersive X-ray diffraction

    Science.gov (United States)

    Gröschel, A.; Will, J.; Bergmann, C.; Magerl, A.

    2014-06-01

    Annealed Czochralski Silicon wafers containing SiOx precipitates have been studied by high energy X-ray diffraction in a defocused Laue setup using a laboratory tungsten tube. The energy dispersive evaluation of the diffracted Bragg intensity of the 220 reflection within the framework of the statistical dynamical theory yields the static Debye-Waller factor E of the crystal, which gives access to the strain induced by the SiOx precipitates. The results are correlated with precipitate densities and sizes determined from transmission electron microscopy measurements of equivalent wafers. This allows for the determination of the constrained linear misfit ɛ between precipitate and crystal lattice. For samples with octahedral precipitates the values ranging from ɛ = 0.39 (+0.28/-0.12) to ɛ = 0.48 (+0.34/-0.16) indicate that self-interstitials emitted into the matrix during precipitate growth contribute to the lattice strain. In this case, the expected value calculated from literature values is ɛ = 0.26 ± 0.05. Further, the precise evaluation of Pendellösung oscillations in the diffracted Bragg intensity of as-grown wafers reveals a thermal Debye-Waller parameter for the 220 reflection B220(293 K) of 0.5582 ± 0.0039 Å2 for a structure factor based on spherically symmetric scattering contributions.

  14. Laboratory implementation of edge illumination X-ray phase-contrast imaging with energy-resolved detectors

    Science.gov (United States)

    Diemoz, P. C.; Endrizzi, M.; Vittoria, F. A.; Hagen, C. K.; Kallon, G.; Basta, D.; Marenzana, M.; Delogu, P.; Vincenzi, A.; De Ruvo, L.; Spandre, G.; Brez, A.; Bellazzini, R.; Olivo, A.

    2015-03-01

    Edge illumination (EI) X-ray phase-contrast imaging (XPCI) has potential for applications in different fields of research, including materials science, non-destructive industrial testing, small-animal imaging, and medical imaging. One of its main advantages is the compatibility with laboratory equipment, in particular with conventional non-microfocal sources, which makes its exploitation in normal research laboratories possible. In this work, we demonstrate that the signal in laboratory implementations of EI can be correctly described with the use of the simplified geometrical optics. Besides enabling the derivation of simple expressions for the sensitivity and spatial resolution of a given EI setup, this model also highlights the EI's achromaticity. With the aim of improving image quality, as well as to take advantage of the fact that all energies in the spectrum contribute to the image contrast, we carried out EI acquisitions using a photon-counting energy-resolved detector. The obtained results demonstrate that this approach has great potential for future laboratory implementations of EI.

  15. Technical note: Prediction of chemical rib section composition by dual energy X-ray absorptiometry in Zebu beef cattle.

    Science.gov (United States)

    Prados, L F; Zanetti, D; Amaral, P M; Mariz, L D S; Sathler, D F T; Filho, S C Valadares; Silva, F F; Silva, B C; Pacheco, M C; Alhadas, H M; Chizzotti, M L

    2016-06-01

    It is expensive and laborious to evaluate carcass composition in beef cattle. The objective of this study was to evaluate a method to predict the 9th to 11th rib section (rib) composition through empirical equations using dual energy X-ray absorptiometry (DXA). Dual energy X-ray absorptiometry is a validated method used to describe tissue composition in humans and other animals, but few studies have evaluated this technique in beef cattle, and especially in the Zebu genotype. A total of 116 rib were used to evaluate published prediction equations for rib composition and to develop new regression models using a cross-validation procedure. For the proposed models, 93 ribs were randomly selected to calculate the new regression equations, and 23 different ribs were randomly selected to validate the regressions. The rib from left carcasses were taken from Nellore and Nellore × Angus bulls from 3 different studies and scanned using DXA equipment (GE Healthcare, Madison, WI) in the Health Division at Universidade Federal de Viçosa (Viçosa, Brazil). The outputs of the DXA report were DXA lean (g), DXA fat free mass (g), DXA fat mass (g), and DXA bone mineral content (BMC; g). After being scanned, the rib were dissected, ground, and chemically analyzed for total ether extract (EE), CP, water, and ash content. The predictions of rib fat and protein from previous published equations were different ( composition. New equations were established through leave-one-out cross-validation using the REG procedure in SAS. The equations were as follows: lean (g) = 37.082 + 0.907× DXA lean ( = 0.95); fat free mass (g) = 103.224 + 0.869 × DXA fat free mass ( = 0.93); EE mass (g) = 122.404 + 1.119 × DXA fat mass ( = 0.86); and ash mass (g) = 18.722 + 1.016 × DXA BMC ( = 0.39). The equations were validated using Mayer's test, the concordance correlation coefficient, and the mean square error of prediction for decomposition. For both equations, Mayer's test indicated that if the

  16. Handbook of X-Ray Data

    CERN Document Server

    Zschornack, Günter

    2007-01-01

    This sourcebook is intended as an X-ray data reference for scientists and engineers working in the field of energy or wavelength dispersive X-ray spectrometry and related fields of basic and applied research, technology, or process and quality controlling. In a concise and informative manner, the most important data connected with the emission of characteristic X-ray lines are tabulated for all elements up to Z = 95 (Americium). This includes X-ray energies, emission rates and widths as well as level characteristics such as binding energies, fluorescence yields, level widths and absorption edges. The tabulated data are characterized and, in most cases, evaluated. Furthermore, all important processes and phenomena connected with the production, emission and detection of characteristic X-rays are discussed. This reference book addresses all researchers and practitioners working with X-ray radiation and fills a gap in the available literature.

  17. Dual-energy X-ray micro-CT imaging of hybrid Ni/Al open-cell foam

    Czech Academy of Sciences Publication Activity Database

    Fíla, T.; Kumpová, Ivana; Koudelka_ml., P.; Zlámal, P.; Vavřík, Daniel; Jiroušek, O.; Jung, A.

    2016-01-01

    Roč. 11, č. 1 (2016), C01005 ISSN 1748-0221. [International Workshop on Radiation Imaging Detectors (IWORID2015) /17./. Hamburg, 28.06.2015-02.07.2015] Institutional support: RVO:68378297 Keywords : computerized tomography (CT) * computed radiography (CR) * X-ray radiography and digital radiography (DR) * inspection with x-rays Subject RIV: JJ - Other Materials Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/11/01/C01005/pdf

  18. Evaluation of decision rules for referring women for bone densitometry by dual-energy x-ray absorptiometry.

    Science.gov (United States)

    Cadarette, S M; Jaglal, S B; Murray, T M; McIsaac, W J; Joseph, L; Brown, J P

    2001-07-04

    Identification of women with low bone mineral density (BMD) is an important strategy in reducing the incidence of osteoporotic fractures. However, screening all women is not recommended. To assess the diagnostic properties of 4 decision rules--Simple Calculated Osteoporosis Risk Estimation (SCORE), Osteoporosis Risk Assessment Instrument (ORAI), Age, Body Size, No Estrogen (ABONE), and body weight less than 70 kg (weight criterion)--for selecting women for dual-energy x-ray absorptiometry (DXA) testing and to compare results with recommendations made in the National Osteoporosis Foundation (NOF) practice guidelines. Analysis of data from the Canadian Multicentre Osteoporosis Study, a population-based community sample, collected from 9 study centers across Canada between February 1996 and September 1997. Postmenopausal women aged 45 years or older (N = 2365) without bone disease who had DXA data for the femoral neck, data to apply selection criteria, and who were not currently taking estrogens or who had been taking hormone replacement therapy for 5 or more years. Sensitivity, specificity, and area under the receiver operating characteristic (AUROC) curve of each of the 4 decision rules and the NOF guidelines for identifying women with a BMD T score of less than -1.0 SD, less than -2.0 SD, and no more than -2.5 SD at the femoral neck, and percentages of women recommended for testing, stratified by BMD level and age. The percent of women with a BMD T score less than -1, less than -2, and no more than -2.5 were 68.3%, 25.4%, and 10.0%, respectively. The AUROC curves were greatest using SCORE and ORAI. The sensitivity for identifying women with a BMD T score of less than -2.0 was 93.7% (95% confidence interval [CI], 91.8%-95.6%) using the NOF guidelines and was 97.5% (95% CI, 96.3%-98.8%), 94.2% (95% CI, 92.3%-96.1%), 79.1% (95% CI, 75.9%-82.3%), and 79.6% (95% CI, 76.4%-82.8%), respectively, using the SCORE, ORAI, ABONE, and weight criterion. However, the NOF

  19. A reliable method for measuring proximal tibia and distal femur bone mineral density using dual-energy X-ray absorptiometry

    NARCIS (Netherlands)

    Bakkum, Arjan J. T.; Janssen, Thomas W. J.; Rolf, Marijn P.; Roos, Jan C.; Burcksen, Jos; Knol, Dirk L.; de Groot, Sonja

    Purpose: To assess the intra- and inter-rater reliability of a standardized protocol for measuring proximal tibia and distal femur bone mineral density (BMD) using dual-energy X-ray absorptiometry (DXA). Methods: Ten able-bodied individuals (7 males) participated in this study. During one

  20. Accuracy and the influence of marrow fat on quantitative CT and dual-energy X-ray absorptiometry measurements of the femoral neck in vitro

    NARCIS (Netherlands)

    J.-W. Kuiper (Jan-Willem); C. van Kuijk (Cornelis); J.L. Grashuis (Jan); A.G.H. Ederveen (Antwan); H.E. Schütte (Henri)

    1996-01-01

    markdownabstractAbstract Bone mineral measurements with quantitative computed tomography (QCT) and dual-energy X-ray absorptiometry (DXA) were compared with chemical analysis (ChA) to determine (1) the accuracy and (2) the influence of bone marrow fat. Total bone mass of 19 human femoral necks in

  1. Fundamental Movement Skill Proficiency and Body Composition Measured by Dual Energy X-Ray Absorptiometry in Eight-Year-Old Children

    Science.gov (United States)

    Slotte, Sari; Sääkslahti, Arja; Metsämuuronen, Jari; Rintala, Pauli

    2015-01-01

    Objective: The main aim was to examine the association between fundamental movement skills (FMS) and objectively measured body composition using dual energy X-ray absorptiometry (DXA). Methods: A study of 304 eight-year-old children in Finland. FMS were assessed with the "Test of gross motor development," 2nd ed. Total body fat…

  2. Reference data for bone density and body composition measured with dual energy x ray absorptiometry in white children and young adults

    NARCIS (Netherlands)

    I.M. van der Sluis (Inge); M.A.J. de Ridder (Maria); A.M. Boot (Annemieke); E.P. Krenning (Eric); S.M.P.F. de Muinck Keizer-Schrama (Sabine)

    2002-01-01

    textabstractAIMS: To obtain normative data on bone mineral density and body composition measured with dual energy x ray absorptiometry (DXA) from early childhood to young adulthood. METHODS: Cross sectional results from 444 healthy white volunteers (4-20 years) in the Netherlands

  3. Determining the platinum loading and distribution of industrial scale polymer electrolyte membrane fuel cell electrodes using low energy X-ray imaging

    DEFF Research Database (Denmark)

    Holst, T.; Vassiliev, Anton; Kerr, R.

    2014-01-01

    Low energy X-ray imaging (E gas diffusion electrodes for polymer electrolyte membrane fuel cells. A linear...... correlation was found in order for the average image grayscale intensity to be calibrated to the platinum loading, while the platinum distribution was mapped across the electrode geometric area. The resolution was found to be sufficient in identifying flaws and inhomogeneities in the catalyst layer...

  4. Hard X-ray Zone Plates Using Ultrananocrystalline Diamond Molds

    Science.gov (United States)

    Wojcik, M. J.; Joshi, V.; Sumant, A. V.; Divan, R.; Ocola, L. E.; Lu, M.; Mancini, D. C.

    2011-09-01

    While hard x-ray zone plates have made great advances recently towards improved resolution, their focusing efficiency requires further development. This problem becomes more important as higher-energy x-rays are used for x-ray microscopy. The current method for fabricating zone plates involves a dielectric mold, which is then electroplated into, but the materials used for this mold are not mechanically stiff enough for the zone plates desired. Ultrananocrystalline diamond (UNCD) is a form of diamond that can be grown as a thin film by chemical vapor deposition and offers many of the physical properties of bulk diamond. Its mechanical stiffness, resistance to radiation damage, dielectric properties, and ability to be etched suggests UNCD as a capable mold material. Reported is progress in the fabrication of hard x-ray zone plates with gold electroformed into a UNCD mold.

  5. Quantitative evaluation of material composition of composites using x-ray energy-dispersive NDE technique

    Energy Technology Data Exchange (ETDEWEB)

    Ting, Jason [Iowa State Univ., Ames, IA (United States)

    1993-09-01

    This technique worked well for determining the thickness and densities for composite components having the higher linear attenuation coefficient; it accurately determined thickness of epoxy-resin and Al metal, and the denisty of bone, to ≤ 4% in the graphite-epoxy, bone-plexiglas, and Al-Al corrosion composites. Accuracy is dictated by the magnitude and uncertainty of the linear attenuation coefficient. Use of Ge detector and multichannel analyzer are limited by inspection time (1 day for point measurement) and access limitation. Immediate development of a rapid in-service inspection tool is limited by the amplifier and MCA systems. The MCA should be replaced with a single-channel analyzer, and an electronic device should be built for monitoring the incoming signal for Pile-Up-Rejection.

  6. Energy dispersive X-ray fluorescence detection of heavy metals in Bangladesh cows' milk.

    Science.gov (United States)

    Jolly, Y N; Iqbal, Shahriar; Rahman, M S; Kabir, J; Akter, S; Ahmad, Iftekhar

    2017-09-01

    It is considered that cow's milk is almost complete food for human as it provides most of the micronutrients and macronutrients. The cow's milks are essential for the growth and development especially for children. The main compositions of cow's milk are protein, fat, carbohydrates, vitamins and minerals which are well defined. Presently, the study of micronutrients and toxic elements in cow's milk has been widely carried out particularly in the industrialized and polluted regions because of its possibility of contamination, and thereby health risk of the consumers. The elemental composition in local cow's milk samples in Bangladesh is not well studied yet. The present study was therefore aimed to determine the level of heavy metals (Cr, Ni, As, Cd, Hg, Pb, Mn, Cu, Zn and Fe) in cow's milk using EDXRF technique. Subsequently, the experimental data was used to calculate the human health risk through the intake of both powder and liquid cows' milk available in Bangladesh. The results showed that powder milk contains significantly higher concentration of heavy metals than liquid milk samples. The HRI (health risk index) and HI (hazard index) values for most of the elements in all milk samples were within the safe limit (milk samples for both children and adult showed a value higher than one (>1). MPI (metal pollution index) value for powder milk samples are very high compared to other type of milk samples analyzed in this study. Therefore, it has been suggested that heavy metal contamination through local powder milk samples might have significant negative impact (threat) on human health.

  7. X-Ray Polarimetry

    OpenAIRE

    Kaaret, Philip

    2014-01-01

    We review the basic principles of X-ray polarimetry and current detector technologies based on the photoelectric effect, Bragg reflection, and Compton scattering. Recent technological advances in high-spatial-resolution gas-filled X-ray detectors have enabled efficient polarimeters exploiting the photoelectric effect that hold great scientific promise for X-ray polarimetry in the 2-10 keV band. Advances in the fabrication of multilayer optics have made feasible the construction of broad-band ...

  8. Energy dispersive X-ray fluorescence detection of heavy metals in Bangladesh cows’ milk

    Directory of Open Access Journals (Sweden)

    Y.N. Jolly

    2017-09-01

    Full Text Available It is considered that cow's milk is almost complete food for human as it provides most of the micronutrients and macronutrients. The cow's milks are essential for the growth and development especially for children. The main compositions of cow's milk are protein, fat, carbohydrates, vitamins and minerals which are well defined. Presently, the study of micronutrients and toxic elements in cow's milk has been widely carried out particularly in the industrialized and polluted regions because of its possibility of contamination, and thereby health risk of the consumers. The elemental composition in local cow's milk samples in Bangladesh is not well studied yet. The present study was therefore aimed to determine the level of heavy metals (Cr, Ni, As, Cd, Hg, Pb, Mn, Cu, Zn and Fe in cow's milk using EDXRF technique. Subsequently, the experimental data was used to calculate the human health risk through the intake of both powder and liquid cows’ milk available in Bangladesh. The results showed that powder milk contains significantly higher concentration of heavy metals than liquid milk samples. The HRI (health risk index and HI (hazard index values for most of the elements in all milk samples were within the safe limit (1. MPI (metal pollution index value for powder milk samples are very high compared to other type of milk samples analyzed in this study. Therefore, it has been suggested that heavy metal contamination through local powder milk samples might have significant negative impact (threat on human health.

  9. X-ray radiography for container inspection

    Science.gov (United States)

    Katz, Jonathan I [Clayton, MO; Morris, Christopher L [Los Alamos, NM

    2011-06-07

    Arrangements of X-ray inspection systems are described for inspecting high-z materials in voluminous objects such as containers. Inspection methods may involve generating a radiographic image based on detected attenuation corresponding to a pulsed beams of radiation transmitted through a voluminous object. The pulsed beams of radiation are generated by a high-energy source and transmitted substantially downward along an incident angle, of approximately 1.degree. to 30.degree., to a vertical axis extending through the voluminous object. The generated radiographic image may be analyzed to detect on localized high attenuation representative of high-z materials and to discriminate high-z materials from lower and intermediate-z materials on the basis of the high density and greater attenuation of high-z material for higher energy (3-10 MeV) X-rays, and the compact nature of threatening masses of fissionable materials.

  10. In situ electrochemical high-energy X-ray diffraction using a capillary working electrode cell geometry

    Energy Technology Data Exchange (ETDEWEB)

    Young, Matthias J.; Bedford, Nicholas M.; Jiang, Naisheng; Lin, Deqing; Dai, Liming

    2017-05-26

    The ability to generate new electrochemically active materials for energy generation and storage with improved properties will likely be derived from an understanding of atomic-scale structure/function relationships during electrochemical events. Here, the design and implementation of a new capillary electrochemical cell designed specifically forin situhigh-energy X-ray diffraction measurements is described. By increasing the amount of electrochemically active material in the X-ray path while implementing low-Zcell materials with anisotropic scattering profiles, an order of magnitude enhancement in diffracted X-ray signal over traditional cell geometries for multiple electrochemically active materials is demonstrated. This signal improvement is crucial for high-energy X-ray diffraction measurements and subsequent Fourier transformation into atomic pair distribution functions for atomic-scale structural analysis. As an example, clear structural changes in LiCoO2under reductive and oxidative conditions using the capillary cell are demonstrated, which agree with prior studies. Accurate modeling of the LiCoO2diffraction data using reverse Monte Carlo simulations further verifies accurate background subtraction and strong signal from the electrochemically active material, enabled by the capillary working electrode geometry.

  11. A chemical signal possibly related to physiology in fossil cells detected by energy dispersive X-ray microanalysis.

    Science.gov (United States)

    Wang, X

    2006-02-01

    Energy dispersive X-ray microanalysis (EDXMA) is a widely used tool employed to detect elemental composition and its spatial distribution in a sample without causing damage. Charcoalified cytoplasm is a new type of fossil material that came to people's attention only recently. In this paper, EDXMA is used for the first time to detect the spatial elemental distribution in charcoalified cytoplasm of two fossil plants that are more than 100 million years old. The results demonstrate certain elemental distribution patterns within charcoalified cytoplasm and the surrounding cell walls. Based on the results from cytological studies of extant material, the heterogeneous spatial elemental distribution within the charcoalified cytoplasm has the potential to be related to the maturation of cells, the presence of certain organelles, and the physiology of these organelles. This is the first chemical signal detected in cytoplasm residue that can possibly be related to plant physiology. This paves the way for further research on fossil cytoplasm, which will better our understanding on the physiology of fossil plants.

  12. Agreement between dual energy X-ray absorptiometry and opto-electronic volumetry for measurement of forearm volume.

    Science.gov (United States)

    Santin, Laís; Ward, Leigh C

    2014-09-01

    Lymphedema is commonly assessed by measuring the increase in volume of the affected region using methods that are not only accurate and sensitive but also applicable for use in clinical practice. Opto-electronic volumetry (Perometer™) is a rapid and convenient technique recommended as a reference method for this purpose, while the use of dual-energy X-ray absorptiometry is becoming more common. We report here a method agreement study between DXA and perometry for the measurement of forearm volume. Perometric measurements were performed on both whole arms, in the horizontal plane, of a group of healthy young participants. Perometric data were obtained for 4 and 5 mm slices between the malleoli to the anticubital fossa crease. The DXA-measured masses (bone mineral, fat, and lean) for the same forearm region were obtained using recently published algorithms. Perometric and DXA-measured volumes were compared using correlation and limits of agreement analysis. DXA-computed volumes were highly and significantly correlated (r=0.986; pperometry. The mean bias between the methods was extremely small; 0.7% underestimation by DXA with limits of agreement of 6.3 to -7.7% (DXA-perometry). This study has demonstrated a high degree of concordance between DXA computed limb volumes and those measured by the reference method of perometry. The relatively small limits of agreement suggest that these methods can be used interchangeably.

  13. 3D Atomic Arrangement at Functional Interfaces Inside Nanoparticles by Resonant High-Energy X-ray Diffraction.

    Science.gov (United States)

    Petkov, Valeri; Prasai, Binay; Shastri, Sarvjit; Chen, Tsan-Yao

    2015-10-21

    With current science and technology moving rapidly into smaller scales, nanometer-sized materials, often referred to as NPs, are produced in increasing numbers and explored for numerous useful applications. Evidence is mounting, however, that useful properties of NPs can be improved further and even new NP functionality achieved by not only controlling the NP size and shape but also interfacing chemically or structurally distinct entities into single, so-called "composite" NPs. A typical example is core-shell NPs wherein the synergy of distinct atoms at the core\\shell interface endows the NPs with otherwise unachievable functionality. However, though advantageous, the concept of functional interfaces inside NPs is still pursued largely by trial-and-error. That is because it is difficut to assess the interfaces precisely at the atomic level using traditional experimental techniques and, hence, difficult to take control of. Using the core\\shell interface in less than 10 nm in size Ru core-Pt shells NPs as an example, we demonstrate that precise knowledge of the 3D atomic arrangement at functional interfaces inside NPs can be obtained by resonant high-energy X-ray diffraction (XRD) coupled to element-specific atomic pair distribution function (PDF) analysis. On the basis of the unique structure knowledge obtained, we scrutinize the still-debatable influence of core\\shell interface on the catalytic functionality of Ru core-Pt shell NPs, thus evidencing the usefulness of this nontraditional technique for practical applications.

  14. Assessment of human body composition using dual-energy x-ray absorptiometry and bioelectrical impedance analysis.

    Science.gov (United States)

    Bolanowski, M; Nilsson, B E

    2001-01-01

    Human body composition, particularly the content of fat tissue and its distribution, has been extensively measured in healthy, diseased, obese and elderly subjects. A variety of non-invasive methods have been applied for these studies. Bioelectrical impedance analysis (BIA) is a commonly used method, based on the conduction of electrical current in the body and the differences in the ability to conduct electricity between the fat and water components of the body. Recently, dual-energy x-ray absorptiometry (DEXA) has been introduced for bone mass, bone mineral density and body composition studies. Unlike other methods, DEXA measures three components of the body: bone mineral content, fat tissue mass, and lean tissue mass, and additionally regional fat distribution. The objective of this study was to compare body composition as assessed by DEXA and BIA methods in a sample of 100 patients. Body composition was studied in 100 consecutive subjects, 59 women and 41 men. The lean body mass (LBM), fat body mass (FBM), and percent body fat (%BF) were measured by the DEXA and BIA techniques. There were highly statistically significant linear relationships between LBM, FBM and %BF assessed by DEXA and BIA in both sexes (pfat and fat-free tissue. The results suggest that DEXA may underestimate the LBM and overestimate body fat compared with BIA, probably due to different assumptions about the constants. We conclude that both methods are suitable for body composition studies.

  15. Total and regional bone mineral content in healthy Spanish subjects by dual-energy X-ray absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Aguado Henche, S.; Rodriguez Torres, R.; Clemente de Arriba, C.; Gomez Pellico, L. [Universidad de Alcala, Departamento de Anatomia y Embriologia Humana, Facultad de Medicina, Alcala de Henares, Madrid (Spain)

    2008-11-15

    This is an observational cross-sectional study. The aim of the present study was to describe and analyze patterns of change in total and regional bone mineral content in relation to age and gender in a sedentary Spanish sample population (from the Community of Madrid). The age range of the sample population was from birth to 80 years. One thousand one hundred twenty healthy subjects were recruited and divided into 16 groups according to age. Each subject underwent whole-body densitometry using dual-energy X-ray absorptiometry. An analysis was made of the amount of bone mineral content (BMC) in the whole body and in different regions: the head, trunk, upper limbs, and lower limbs. Gender differences in mean values for upper limbs and lower limbs are statistically significant between 16 and 70 years of age. For the head and trunk, the mean BMC values show the most significant gender differences between 16 and 25 years of age (p{<=}0.001). Total bone mineral content (TBMC) and TBMC-to-height ratio show significant gender differences between 16 and 70 years of age. In females, TBMC values increase up to 20 years of age and in males up to 25 years of age. We have determined an evolutionary normal pattern of bone mineral content in urban Spanish people. (orig.)

  16. An accelerator scenario for a hard X-ray free electron laser combined with high energy electron radiography

    Science.gov (United States)

    Wei, Tao; Li, Yiding; Yang, Guojun; Pang, Jian; Li, Yuhui; Li, Peng; Pflueger, Joachim; He, Xiaozhong; Lu, Yaxin; Wang, Ke; Long, Jidong; Zhang, Linwen; Wu, Qiang

    2016-08-01

    In order to study the dynamic response of the material and the physical mechanism of fluid dynamics, an accelerator scenario which can be applied to both hard X-ray free electron laser and high energy electron radiography is proposed. This accelerator is mainly composed of a 12 GeV linac, an undulator branch and an eRad beamline. In order to characterize a sample’s dynamic behavior in situ and real-time with XFEL and eRad simultaneously, the linac should be capable of accelerating the two kinds of beam within the same operation mode. Combining in-vacuum and tapering techniques, the undulator branch can produce more than 1011 photons per pulse in 0.1% bandwidth at 42 keV. Finally, an eRad amplifying beamline with 1:10 ratio is proposed as an important complementary tool for the wider view field and density identification ability. Supported by China Academy of Engineering Physics (2014A0402016) and Institute of Fluid Physics (SFZ20140201)

  17. Dual-energy X-ray absorptiometry diagnostic discordance between Z-scores and T-scores in young adults.

    LENUS (Irish Health Repository)

    Carey, John J

    2009-01-01

    Diagnostic criteria for postmenopausal osteoporosis using central dual-energy X-ray absorptiometry (DXA) T-scores have been widely accepted. The validity of these criteria for other populations, including premenopausal women and young men, has not been established. The International Society for Clinical Densitometry (ISCD) recommends using DXA Z-scores, not T-scores, for diagnosis in premenopausal women and men aged 20-49 yr, though studies supporting this position have not been published. We examined diagnostic agreement between DXA-generated T-scores and Z-scores in a cohort of men and women aged 20-49 yr, using 1994 World Health Organization and 2005 ISCD DXA criteria. Four thousand two hundred and seventy-five unique subjects were available for analysis. The agreement between DXA T-scores and Z-scores was moderate (Cohen\\'s kappa: 0.53-0.75). The use of Z-scores resulted in significantly fewer (McNemar\\'s p<0.001) subjects diagnosed with "osteopenia," "low bone mass for age," or "osteoporosis." Thirty-nine percent of Hologic (Hologic, Inc., Bedford, MA) subjects and 30% of Lunar (GE Lunar, GE Madison, WI) subjects diagnosed with "osteoporosis" by T-score were reclassified as either "normal" or "osteopenia" when their Z-score was used. Substitution of DXA Z-scores for T-scores results in significant diagnostic disagreement and significantly fewer persons being diagnosed with low bone mineral density.

  18. NASA Li/CF(x) cell problem analysis: Scanning electron microscopy with energy dispersive x ray spectrometry

    Science.gov (United States)

    Baker, John

    1991-01-01

    An analysis was made of Lithium/carbon fluoride cell parts for possible chloride contamination induced by exposure to thionyl chloride (SOCl2); various samples were submitted for analysis. Only a portion of the analysis which has been conducted is covered, herein, namely analysis by scanning electron microscopy with energy dispersive x ray spectrometry (SEM/EDS). A strip of nickel was exposed to SOCl2 vapors to observe variations in surface concentrations of sulfur and chlorine with time. By detecting chlorine one can not infer contamination by SOCl2 only that contamination is present. Six samples of stainless steel foil were analyzed for chlorine using EDS. Chlorine was not detected on background samples but was detected on the samples which had been handled including those which had been cleaned. Cell covers suspected of being contaminated while in storage and covers which were not exposed to the same storage conditions were analyzed for chlorine. Although no chlorine was found on the covers from cells, it was found on all stored covers. Results are presented with techniques shown for analysis and identification. Relevant photomicrographs are presented.

  19. Distribution of toxic elements in teeth treated with amalgam using μ-energy dispersive X-ray fluorescence

    Science.gov (United States)

    Guerra, M.; Ferreira, C.; Carvalho, M. L.; Santos, J. P.; Pessanha, S.

    2016-08-01

    Over the years, the presence of mercury in amalgam fillings has raised some safety concerns. Amalgam is one of the most commonly used tooth fillings and contains approximately 50% of elemental mercury and 50% of other metals, mostly silver, tin and copper. Amalgam can release small amounts of mercury vapor over time, and patients can absorb these vapors by inhaling or ingesting them. In this study, 10 human teeth treated with dental amalgam were analyzed using energy dispersive X-ray fluorescence (EDXRF) to study the diffusion of its constituents, Ag, Cu, Sn and Hg. The used EDXRF setup, makes use of a polycapillary lens to focus radiation up to 25 μm allowing the mapping of the elemental distribution in the samples. Quantification was performed using the inbuilt software based on the Fundamental Parameters method for bulk samples, considering a hydroxyapatite matrix. The teeth were longitudinally cut and each slice was scanned from the surface enamel to the inner region (dentin and pulp cavity). Mercury concentration profiles show strong levels of this element close to the amalgam region, decreasing significantly in the dentin, and increasing again up to 40,000 μg·g- 1 in the cavity were the pulp used to exist when the tooth was vital.

  20. In situ compressibility of carbonated hydroxyapatite in tooth dentine measured under hydrostatic pressure by high energy X-ray diffraction.

    Science.gov (United States)

    Forien, Jean-Baptiste; Fleck, Claudia; Krywka, Christina; Zolotoyabko, Emil; Zaslansky, Paul

    2015-10-01

    Tooth dentine and other bone-like materials contain carbonated hydroxyapatite nanoparticles within a network of collagen fibrils. It is widely assumed that the elastic properties of biogenic hydroxyapatites are identical to those of geological apatite. By applying hydrostatic pressure and by in situ measurements of the a- and c- lattice parameters using high energy X-ray diffraction, we characterize the anisotropic deformability of the mineral in the crowns and roots of teeth. The collected data allowed us to calculate the bulk modulus and to derive precise estimates of Young׳s moduli and Poisson׳s ratios of the biogenic mineral particles. The results show that the dentine apatite particles are about 20% less stiff than geological and synthetic apatites and that the mineral has an average bulk modulus K=82.7 GPa. A 5% anisotropy is observed in the derived values of Young׳s moduli, with E11≈91 GPa and E33≈96 GPa, indicating that the nanoparticles are only slightly stiffer along their long axis. Poisson׳s ratio spans ν≈0.30-0.35, as expected. Our findings suggest that the carbonated nanoparticles of biogenic apatite are significantly softer than previously thought and that their elastic properties can be considered to be nearly isotropic. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Correspondence between theoretical models and dual energy x-ray absorptiometry measurements of femoral cross-sectional growth during adolescence

    Science.gov (United States)

    van der Meulen, M. C.; Marcus, R.; Bachrach, L. K.; Carter, D. R.

    1997-01-01

    We have developed an analytical model of long bone cross-sectional ontogeny in which appositional growth of the diaphysis is primarily driven by mechanical stimuli associated with increasing body mass during growth and development. In this study, our goal was to compare theoretical predictions of femoral diaphyseal structure from this model with measurements of femoral bone mineral and geometry by dual energy x-ray absorptiometry. Measurements of mid-diaphyseal femoral geometry and structure were made previously in 101 Caucasian adolescents and young adults 9-26 years of age. The data on measured bone mineral content and calculated section modulus were compared with the results of our analytical model of cross-sectional development of the human femur over the same age range. Both bone mineral content and section modulus showed good correspondence with experimental measurements when the relationships with age and body mass were examined. Strong linear relationships were evident for both parameters when examined as a function of body mass.

  2. Atomic-scale Chemical Imaging and Quantification of Metallic Alloy Structures by Energy-Dispersive X-ray Spectroscopy

    Science.gov (United States)

    Lu, Ping; Zhou, Lin; Kramer, M. J.; Smith, David J.

    2014-01-01

    Determination of atomic-scale crystal structure for nanostructured intermetallic alloys, such as magnetic alloys containing Al, Ni, Co (alnico) and Fe, is crucial for understanding physical properties such as magnetism, but technically challenging due to the small interatomic distances and the similar atomic numbers. By applying energy-dispersive X-ray spectroscopy (EDS) mapping to the study of two intermetallic phases of an alnico alloy resulting from spinodal decomposition, we have determined atomic-scale chemical composition at individual lattice sites for the two phases: one is the B2 phase with Fe0.76Co0.24 -Fe0.40Co0.60 ordering and the other is the L21 phase with Ni0.48Co0.52 at A-sites, Al at BΙ-sites and Fe0.20Ti0.80 at BΙΙ-sites, respectively. The technique developed through this study represents a powerful real-space approach to investigate structure chemically at the atomic scale for a wide range of materials systems. PMID:24492747

  3. A study of heavy metal pollution in Lake Victoria sediments by Energy Dispersive X-Ray Fluorescence.

    Science.gov (United States)

    Makundi, I N

    2001-01-01

    Sources of heavy metal pollution of Lake Victoria is of interest due to its economic and domestic implication in East Africa. Sediments from the shore of Lake Victoria and from some streams flowing into the lake have been analyzed for their heavy metal content using Energy Dispersive X-Ray Fluorescence (EDXRF) analysis. The samples were collected from seventeen different locations around the Municipality of Mwanza divided into three zones according to their activities. The results show that sediments from Mwanza North, which is least in anthropogenic activities, contains Cr and Co in addition to metals of terrestrial origin (K, Ca, Ti, Mn, Fe, Rb, Sr, Y, and Zr), samples from Mwanza Central, which is the town center, contains high concentrations of V, Cu, Zn and Pb, and samples collected from Mwanza South, which is the industrial area, contains the highest concentrations of V, Cu, Zn, As and Pb. It is concluded that the industrial and sewage wastes discharged into the lake are the main sources of the heavy metal contamination of Lake Victoria. Further studies will be required to assess detriments of these pollutants to human and aquatic life before policy for the factories responsible is put in place.

  4. Beamline electrostatic levitator for in situ high energy x-ray diffraction studies of levitated solids and liquids

    Energy Technology Data Exchange (ETDEWEB)

    Gangopadhyay, A.K.; Lee, G.W.; Kelto, K.F.; Rogers, J.R.; Goldman, A.I.; Robinson, D.S.; Rathz, T.J.; Hyers, R.W. (WU); (UAB); (NASA); (UMASS, Amherst)

    2010-07-19

    Determinations of the phase formation sequence, crystal structures and the thermo-physical properties of materials at high temperatures are hampered by contamination from the sample container and environment. Containerless processing techniques, such as electrostatic (ESL), electromagnetic, aerodynamic, and acoustic levitation, are most suitable for these studies. An adaptation of ESL for in situ structural studies of a wide range of materials using high energy (30-130 keV) x rays at a synchrotron source is described here. This beamline ESL (BESL) allows the in situ determination of the atomic structures of equilibrium solid and liquid phases, undercooled liquids and time-resolved studies of solid-solid and liquid-solid phase transformations. The use of area detectors enables the rapid acquisition of complete diffraction patterns over a wide range (0.5-14 {angstrom}{sup -1}) of reciprocal space. The wide temperature range (300-2500 K), containerless processing environment under high vacuum (10{sup -7}-10{sup -8} Torr), and fast data acquisition capability, make BESL particularly well suited for phase stability studies of high temperature solids and liquids. An additional, but important, feature of BESL is the capability for simultaneous measurements of a host of thermo-physical properties including the specific heat, enthalpy of transformation, solidus and liquidus temperatures, density, viscosity, and surface tension, all on the same sample during the structural measurements.

  5. Energy dispersive X-ray fluorescence analysis of mine waters from the Migori Gold Mining Belt in Southern Nyanza, Kenya.

    Science.gov (United States)

    Odumo, O B; Mustapha, A O; Patel, J P; Angeyo, H K

    2011-09-01

    Analyses of water samples from Mikei, Osiri, Masara and Macalder (Makalda) gold mines of the Migori gold mining belt of Southwestern Kenya were done to determine the level of heavy metals using the Energy Dispersive X-ray Fluorescence technique. The concentrations of the heavy metals were; copper (29.34 ± 5.01-14,975.59 ± 616.14 μg/L); zinc (33.69 ± 4.29-683.15 ± 32.93 μg/L); arsenic (958.16 ± 60.14-18,047.52 ± 175.00 μg/L) and lead (19.51 ± 5.5-214.53 ± 6.29 μg/L). High levels of arsenic and lead were noted. These heavy metals are not only dangerous to the lives of miners and the local inhabitants; they are also a threat to aquatic life since these waters finally find their way into Lake Victoria.

  6. Standard test method for analysis of uranium and thorium in soils by energy dispersive X-Ray fluorescence spectroscopy

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the energy dispersive X-ray fluorescence (EDXRF) spectrochemical analysis of trace levels of uranium and thorium in soils. Any sample matrix that differs from the general ground soil composition used for calibration (that is, fertilizer or a sample of mostly rock) would have to be calibrated separately to determine the effect of the different matrix composition. 1.2 The analysis is performed after an initial drying and grinding of the sample, and the results are reported on a dry basis. The sample preparation technique used incorporates into the sample any rocks and organic material present in the soil. This test method of sample preparation differs from other techniques that involve tumbling and sieving the sample. 1.3 Linear calibration is performed over a concentration range from 20 to 1000 μg per gram for uranium and thorium. 1.4 The values stated in SI units are to be regarded as the standard. The inch-pound units in parentheses are for information only. 1.5 This standard...

  7. Best Practices for Dual-Energy X-ray Absorptiometry Measurement and Reporting: International Society for Clinical Densitometry Guidance.

    Science.gov (United States)

    Lewiecki, E Michael; Binkley, Neil; Morgan, Sarah L; Shuhart, Christopher R; Camargos, Bruno Muzzi; Carey, John J; Gordon, Catherine M; Jankowski, Lawrence G; Lee, Joon-Kiong; Leslie, William D

    2016-01-01

    Dual-energy X-ray absorptiometry (DXA) is a technology that is widely used to diagnose osteoporosis, assess fracture risk, and monitor changes in bone mineral density (BMD). The clinical utility of DXA is highly dependent on the quality of the scan acquisition, analysis, and interpretation. Clinicians are best equipped to manage patients when BMD measurements are correct and interpretation follows well-established standards. Poor-quality acquisition, analysis, or interpretation of DXA data may mislead referring clinicians, resulting in unnecessary diagnostic evaluations, failure to evaluate when needed, inappropriate treatment, or failure to provide medical treatment, with potentially ineffective, harmful, or costly consequences. Misallocation of limited healthcare resources and poor treatment decisions can be minimized, and patient care optimized, through meticulous attention to DXA instrument calibration, data acquisition and analysis, interpretation, and reporting. This document from the International Society for Clinical Densitometry describes quality standards for BMD testing at DXA facilities worldwide to provide guidance for DXA supervisors, technologists, interpreters, and clinicians. High-quality DXA testing is necessary for correct diagnostic classification and optimal fracture risk assessment, and is essential for BMD monitoring. Copyright © 2016 International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  8. Relationship between anthropometric and dual energy X-ray absorptiometry measures to assess total and regional adiposity in Malaysian adolescents.

    Science.gov (United States)

    Foo, Leng Huat; Teo, Pey Sze; Abdullah, Nurul Fadhilah; Aziz, Mohd Ezane; Hills, Andrew P

    2013-01-01

    The main objective of this paper was to determine the utility of various anthropometric measures to assess total and regional body fatness using dual-energy X-ray absorptiometry (DXA) as the criterion in 454 adolescent boys and girls aged 12-19 years. Multivariable regression analyses of gender-specific and gender-combined models were used to determine anthropometric measures on DXA-derived body fatness models, after adjusting for known confounding biological factors. Partial correlation analyses, after adjusting for age, pubertal growth status and ethnicity in boys and girls, showed that body mass index (BMI), waist circumference (WC), waist-to-hip ratio (WHR), and waist-height ratio (WhtR) were significantly correlated with total body fat (TBF), percent body fat (%BF), android region fat (ARF) and trunk fat (TF) (all p<0.0001). BMI was the greatest independent determinant, contributing 43.8%-80.9% of the total variance for DXA-derived body fatness models. Results confirmed that a simple anthropometric index such as the BMI is a good surrogate indicator of body fat levels in Malay and Chinese adolescents.

  9. A Complete Overhaul of the Electron Energy-Loss Spectroscopy and X-Ray Absorption Spectroscopy Database: eelsdb.eu.

    Science.gov (United States)

    Ewels, Philip; Sikora, Thierry; Serin, Virginie; Ewels, Chris P; Lajaunie, Luc

    2016-06-01

    The electron energy-loss spectroscopy (EELS) and X-ray absorption spectroscopy (XAS) database has been completely rewritten, with an improved design, user interface, and a number of new tools. The database is accessible at https://eelsdb.eu/ and can now be used without registration. The submission process has been streamlined to encourage spectrum submissions and the new design gives greater emphasis on contributors' original work by highlighting their papers. With numerous new filters and a powerful search function, it is now simple to explore the database of several hundred EELS and XAS spectra. Interactive plots allow spectra to be overlaid, facilitating online comparison. An application-programming interface has been created, allowing external tools and software to easily access the information held within the database. In addition to the database itself, users can post and manage job adverts and read the latest news and events regarding the EELS and XAS communities. In accordance with the ongoing drive toward open access data increasingly demanded by funding bodies, the database will facilitate open access data sharing of EELS and XAS spectra.

  10. Accuracy of dual energy X-ray absorptiometry (DXA) in assessing carcass composition from different pig populations.

    Science.gov (United States)

    Soladoye, O P; López Campos, Ó; Aalhus, J L; Gariépy, C; Shand, P; Juárez, M

    2016-11-01

    The accuracy of dual energy X-ray absorptiometry (DXA) in assessing carcass composition from pigs with diverse characteristics was examined in the present study. A total of 648 pigs from three different sire breeds, two sexes, two slaughter weights and three different diets were employed. DXA estimations were used to predict the dissected/chemical yield for lean and fat of carcass sides and primal cuts. The accuracy of the predictions was assessed based on coefficient of determination (R(2)) and residual standard deviation (RSD). The linear relationships for dissected fat and lean for all the primal cuts and carcass sides were high (R(2)>0.94, Ppork bellies were also high (R(2)>0.94, P<0.01), with RSD <2.9%. These linear relationships remained high over the full range of variation in the pig population, except for sire breed, where the coefficient of determination decreased when carcasses were classified based on this variable. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Measurement of body fat by dual-energy X-ray absorptiometry and bioimpedance analysis in men with prostate cancer.

    Science.gov (United States)

    Smith, Matthew R; Fuchs, Vanessa; Anderson, Ellen J; Fallon, Mary Anne; Manola, Judith

    2002-01-01

    The aims of this study were to determine the percentage of body fat (%BF) by dual-energy x-ray absorptiometry (DXA) and bioelectrical impedance analysis (BIA) using a standard adult equation and BIA using a standard geriatric equation in a population of older men with prostate cancer and to compare the results from these different methods. We conducted a cross-sectional study in 38 men with locally advanced, node-positive, or recurrent prostate cancer and no history of androgen-deprivation therapy. Body composition was evaluated by DXA with the use of a Hologic 4500A densitometer and BIA. BIA %BF was calculated by using standard equations developed for adult and geriatric populations. %BF by DXA, BIA with the standard adult equation, BIA with the standard geriatric equation, and BIA with the age-appropriate equation were 26.7 +/- 5.3%, 22.5 +/- 5.6%, 38.2 +/- 6.9%, and 35.4 +/- 9.6%, respectively. There were statistically significant differences between %BF by DXA and all BIA estimates. By using the methods described by Bland and Altman (Lancet 1986;1(8476):307), the standard adult equation showed the least bias and variability. In this group of men with prostate cancer, BIA with the standard adult equation provided a reasonable estimate of %BF compared with DXA, although the differences were statistically significant. BIA with the standard geriatric equation, however, markedly overestimated %BF compared with DXA, even when its use was restricted to elderly men.

  12. Is bone mineral density measurement using dual-energy X-ray absorptiometry affected by gamma rays?

    Science.gov (United States)

    Xie, Liang-Jun; Li, Jian-Fang; Zeng, Feng-Wei; Jiang, Hang; Cheng, Mu-Hua; Chen, Yi

    2013-01-01

    The objective of this study was to determine whether the gamma rays emitted from the radionuclide effect bone mineral density (BMD) measurement. Nine subjects (mean age: 56 ± 17.96 yr) scheduled for bone scanning underwent BMD measurement using dual-energy X-ray absorptiometry (DXA) (Hologic/Discovery A) before and 1, 2, and 4 h after injection of technetium-99m-methylene diphosphonate (99mTc-MDP). Ten subjects (mean age: 41 ± 15.47 yr) scheduled for therapy of differentiated thyroid carcinoma with iodine-131 underwent BMD measurement before and 2 h after therapeutic radionuclide administration. All patients were given whole body BMD measurement, including head, arm, ribs, lumbar spine, pelvis, and leg sites. Besides, patients who referred to radioiodine therapy were given total hip and femoral neck BMD measurement as well. No statistically significant changes in BMD values were detected after 99mTc-MDP and iodine-131 administration for all measurement sites (p > 0.05), and individual difference of BMD before and after radionuclide imaging or therapy was less than the least significant change in lumbar spine, total hip, and femoral neck. In conclusion, BMD measurements are not influenced by the gamma rays emitted from technetium-99m and iodine-131. DXA bone densitometry may be performed simultaneously with bone scanning and radioiodine therapy. Copyright © 2013 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  13. Scanning Electron Microscopy Findings With Energy-Dispersive X-ray Investigations of Cosmetically Tinted Contact Lenses

    Science.gov (United States)

    Hotta, Fumika; Imai, Shoji; Miyamoto, Tatsuro; Mitamura-Aizawa, Sayaka; Mitamura, Yoshinori

    2015-01-01

    Objective: To investigate the surfaces and principal elements of the colorants of cosmetically tinted contact lenses (Cos-CLs). Methods: We analyzed the surfaces and principal elements of the colorants of five commercially available Cos-CLs using scanning electron microscopy with energy-dispersive x-ray analysis. Results: In two Cos-CLs, the anterior and posterior surfaces were smooth, and colorants were found inside the lens. One lens showed colorants located to a depth of 8 to 14 μm from the anterior side of the lens. In the other lens, colorants were found in the most superficial layer on the posterior surface, although a coated layer was observed. The colorants in the other three lenses were deposited on either lens surface. Although a print pattern was uniform in embedded type lenses, uneven patterns were apparent in dot-matrix design lenses. Colorants used in all lenses contained chlorine, iron, and titanium. In the magnified scanning electron microscopy images of a certain lens, chlorine is exuded and spread. Conclusions: Cosmetically tinted contact lenses have a wide variety of lens surfaces and colorants. Colorants may be deposited on the lens surface and consist of an element that has tissue toxicity. PMID:25799458

  14. Forensic analysis of soil and sediment traces by scanning electron microscopy and energy-dispersive X-ray analysis: an experimental investigation.

    Science.gov (United States)

    Pye, Kenneth; Croft, Debra

    2007-01-05

    This paper reports the results of a series of experiments carried out to determine the precision of soil trace comparisons based on elemental peak height ratios determined by energy-dispersive X-ray analysis (EDXRA) in a variable pressure scanning electron microscope (VP-SEM). Experiments were conducted on 'bulk' soil aggregates, ground powders prepared from the <150 microm soil fractions and on smears of both the bulk soil and <150 microm material placed on cotton cloth. X-ray count data were obtained using area scans and spot analyses at different magnifications. The effects on elemental peak height ratios of varying the SEM chamber pressure, beam spot size, emission current and accelerating voltage were also examined. The peak height ratios for oxygen, silicon, aluminium, potassium, calcium and iron were found to show little variation as a function of chamber pressure, spot size and emission current over the ranges examined, but a strong dependency on accelerating voltage was observed. Within-sample variation in results, expressed by the percentage coefficient of variation, was found to be lowest for area scan analyses of the ground <150 microm fractions and greatest for the spot analyses of the bulk soil aggregates and the <150 microm fractions. We conclude that comparison of elemental peak height ratios determined by EDXRA can be a useful tool for rapid screening of soil samples, especially when combined with investigation of other attributes of the soil traces such as colour, fabric and the composition, shapes and surface textures of individual particles or aggregates within the soil traces. If sufficient material is available and can be readily separated without contamination or loss, higher resolution and more precise elemental data should be obtained by methods such as inductively coupled plasma atomic-emission spectrometry (ICP-AES) or mass-spectrometry (ICP-MS).

  15. Sandia Mark II X-Ray System

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, L.W.

    1979-11-01

    The Sandia Mark II X-Ray System was designed and developed to provide an intense source of mononergetic, ultra-soft x rays with energies between 0.282 and 1.486 keV. The x-ray tube design is similar to one developed by B.L. Henke and incorporates modifications made by Tom Ellsberry. An operations manual section is incorporated to help the experimenter/operator.

  16. Mapping the intake of different elements in vegetal tissues by dual-energy X-ray imaging at DaPhine synchrotron light source.

    Science.gov (United States)

    Reale, L; Kaiser, J; Reale, A; Lai, A; Flora, F; Balerna, A; Cinque, G; Fanelli, M; Ruggieri, F; Faenov, A; Pikuz, T; Tucci, A; Poma, A; Zuppella, P; Liska, M; Malina, R

    2008-03-01

    This article reports on the first utilization of the soft X-ray beamline at the DaPhine synchrotron light source for mapping the intake of different elements in plant tissues. As a test, the method of dual-energy X-ray microradiography was applied to the investigation of the natural su