WorldWideScience

Sample records for higher doses completely

  1. Factors influencing completion of multi-dose vaccine schedules in adolescents: a systematic review

    Directory of Open Access Journals (Sweden)

    K. E. Gallagher

    2016-02-01

    Full Text Available Abstract Background Completion of multiple dose vaccine schedules is crucial to ensure a protective immune response, and maximise vaccine cost-effectiveness. While barriers and facilitators to vaccine uptake have recently been reviewed, there is no comprehensive review of factors influencing subsequent adherence or completion, which is key to achieving vaccine effectiveness. This study identifies and summarises the literature on factors affecting completion of multi-dose vaccine schedules by adolescents. Methods Ten online databases and four websites were searched (February 2014. Studies with analysis of factors predicting completion of multi-dose vaccines were included. Study participants within 9–19 years of age were included in the review. The defined outcome was completion of the vaccine series within 1 year among those who received the first dose. Results Overall, 6159 abstracts were screened, and 502 full texts were reviewed. Sixty one studies were eligible for this review. All except two were set in high-income countries. Included studies evaluated human papillomavirus vaccine, hepatitis A, hepatitis B, and varicella vaccines. Reported vaccine completion rates, among those who initiated vaccination, ranged from 27 % to over 90 %. Minority racial or ethnic groups and inadequate health insurance coverage were risk factors for low completion, irrespective of initiation rates. Parental healthcare seeking behaviour was positively associated with completion. Vaccine delivery in schools was associated with higher completion than delivery in the community or health facilities. Gender, prior healthcare use and socio-economic status rarely remained significant risks or protective factors in multivariate analysis. Conclusions Almost all studies investigating factors affecting completion have been carried out in developed countries and investigate a limited range of variables. Increased understanding of barriers to completion in adolescents will

  2. Adalimumab Dose Tapering in Psoriasis: Predictive Factors for Maintenance of Complete Clearance.

    Science.gov (United States)

    Hansel, Katharina; Bianchi, Leonardo; Lanza, Francesco; Bini, Vittorio; Stingeni, Luca

    2017-03-10

    Psoriasis can be managed successfully with long-term biologics. Real-life clinical practice may require dose tapering as a therapeutic option to reduce the risk of drug-exposure and to increase cost-effectiveness. The responsiveness to extended intervals between adalimumab doses and the possible predictive factors of maintenance of complete clearance were studied in a retrospective 7-year single-centre analysis. Thirty patients who achieved complete clearance with adalimumab underwent dose tapering, progressively extending between-dose intervals (to 21-28 days). Sixty percent of subjects (group A) maintained complete clearance, whereas 40.0% (group B) relapsed and were switched back to the standard dosage to re-achieve complete clearance. Body mass index (BMI) and time to achieve Psoriasis Area Severity Index (PASI-100) with adalimumab standard treatment before dose tapering were significantly lower in group A than in group B (multi-variate Cox regression: p < 0.05, Kaplan-Meier analysis: p < 0.001, respectively). This study suggests that patients with lower BMI and shorter time to achieve PASI-100 with adalimumab standard dose were significantly more likely to be candidates for dose tapering.

  3. Dropout and completion in higher education in Europe: main report

    NARCIS (Netherlands)

    Vossensteyn, Johan J.; Kottmann, Andrea; Jongbloed, Benjamin W.A.; Kaiser, Franciscus; Cremonini, Leon; Stensaker, Bjorn; Hovdhaugen, Elisabeth; Wollscheid, Sabine

    2015-01-01

    Improving completion and reducing dropout in higher education are key concerns for higher education in Europe. This study on dropout and completion in higher education in Europe demonstrates that national governments and higher education institutions use three different study success objectives:

  4. Starting with a higher dose of inhaled corticosteroids in primary care asthma treatment

    NARCIS (Netherlands)

    van der Molen, T; Meyboom-de Jong, B; Mulder, HH; Postma, DS

    New British guidelines on the treatment of asthma (9) advocate starting with a higher dose of inhaled corticosteroids in newly detected asthma patients. We investigated whether initiating inhaled steroid treatment with a higher dose is clinically more effective than a lower dose in steroid naive

  5. Radiation dose reduction for patients with extranodal NK/T-cell lymphoma with complete response after initial induction chemotherapy

    Directory of Open Access Journals (Sweden)

    Wang L

    2016-09-01

    Full Text Available Liang Wang,1,2,* Xi-wen Bi,1,3,* Zhong-jun Xia,1,2 Hui-qiang Huang,1,3 Wen-qi Jiang,1,3 Yu-jing Zhang1,4 1State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, 2Department of Hematologic Oncology, 3Department of Medical Oncology, 4Department of Radiation Oncology, Sun Yat-sen University Cancer Center, Guangzhou, People’s Republic of China *These authors contributed equally to this work Abstract: Previous studies have found that radiotherapy (RT dose less than 50 Gy resulted in inferior outcomes for early stage extranodal NK/T-cell lymphoma (ENKTL. Nowadays, induction chemotherapy (CT followed by RT consolidation is often used. For patients who get complete response (CR after CT, whether RT dose can be safely reduced or not remains unknown. This retrospective study compared the survival outcomes between patients who received higher dose (>50 Gy and lower dose (≤50 Gy RT after CR was attained by CT. One hundred and forty four patients of early stage ENKTL got CR after induction CT and received RT consolidation. Thirty-one patients received lower dose RT (median 46 Gy, range, 36–50 Gy, and 113 patients received higher dose RT (median 56 Gy, range, 52–66 Gy. In univariate survival analysis, age >60, local tumor invasion, and non-asparaginase-based CT were associated with inferior progression-free survival (PFS and overall survival (OS. However, there were no differences in PFS and OS between patients treated with higher and lower dose RT, which was confirmed in the multivariate survival analysis. Furthermore, reduced dose RT did not affect local control rate. Most common RT-related side effects were grade 1/2 mucositis and dermatitis, and the incidence rate of grade 3 mucositis or dermatitis was lower in patients treated with reduced dose RT (9.7% vs 15.0% for mucositis, and 6.5% vs 17.7% for dermatitis. In conclusion, this study found that RT dose could be safely reduced without

  6. The true bladder dose: on average thrice higher than the ICRU reference

    International Nuclear Information System (INIS)

    Barillot, I.; Horiot, J.C.; Maingon, P.; Bone-Lepinoy, M.C.; D'Hombres, A.; Comte, J.; Delignette, A.; Feutray, S.; Vaillant, D.

    1996-01-01

    The aim of this study is to compare ICRU dose to doses at the bladder base located from ultrasonography measurements. Since 1990, the dose delivered to the bladder during utero-vaginal brachytherapy was systematically calculated at 3 or 4 points representative of bladder base determined with ultrasonography. The ICRU Reference Dose (IRD) from films, the Maximum Dose (Dmax), the Mean Dose (Dmean) representative of the dose received by a large area of bladder mucosa, the Reference Dose Rate (RDR) and the Mean Dose Rate (MDR) were recorded. Material: from 1990 to 1994, 198 measurements were performed in 152 patients. 98 patients were treated for cervix carcinomas, 54 for endometrial carcinomas. Methods: Bladder complications were classified using French Italian Syllabus. The influence of doses and dose rates on complications were tested using non parametric t test. Results: On average IRD is 21 Gy +/- 12 Gy, Dmax is 51Gy +/- 21Gy, Dmean is 40 Gy +/16 Gy. On average Dmax is thrice higher than IRD and Dmean twice higher than IRD. The same results are obtained for cervix and endometrium. Comparisons on dose rates were also performed: MDR is on average twice higher than RDR (RDR 48 cGy/h vs MDR 88 cGy/h). The five observed complications consist of incontinence only (3 G1, 1G2, 1G3). They are only statistically correlated with RDR p=0.01 (46 cGy/h in patients without complications vs 74 cGy/h in patients with complications). However the full responsibility of RT remains doubtful and should be shared with surgery in all cases. In summary: Bladder mucosa seems to tolerate well much higher doses than previous recorded without increased risk of severe sequelae. However this finding is probably explained by our efforts to spare most of bladder mucosa by 1 deg. ) customised external irradiation therapy (4 fields, full bladder) 2 deg. ) reproduction of physiologic bladder filling during brachytherapy by intermittent clamping of the Foley catheter

  7. The adequate rocuronium dose required for complete block of the adductor muscles of the thigh.

    Science.gov (United States)

    Fujimoto, M; Kawano, K; Yamamoto, T

    2018-03-01

    Rocuronium can prevent the obturator jerk during transurethral resection of bladder tumors. We investigated the adequate rocuronium dose required for complete block of the thigh adductor muscles, and its correlation with individual responses of the adductor pollicis muscle to rocuronium. Eleven patients scheduled for transurethral resection of bladder tumors under general anesthesia were investigated. After general anesthesia induction, neuromuscular monitoring of the adductor pollicis muscle and ultrasonography-guided stimulation of the obturator nerve was commenced. Rocuronium, 0.15 mg/kg, was repeatedly administered intravenously. The adequate rocuronium dose required for complete block of the thigh muscles, defined as the cumulative dose of rocuronium administered until that time, and its correlation with the first twitch response of the adductor pollicis muscle on train-of-four stimulation after initial rocuronium administration was analyzed. The rocuronium dose found adequate for complete block of the thigh muscles was 0.30 mg/kg in seven patients and 0.45 mg/kg in the remaining four patients, which did not correlate with the first twitch response. At the time of complete block of the thigh muscles, the neuromuscular blockade level of the adductor pollicis muscle varied greatly, although the level was never more profound than a post-tetanic count of 1. Although the response of the adductor pollicis muscle to rocuronium cannot be used to determine the adequate rocuronium dose required for complete block of the thigh muscles, intense blockade, with maintenance of post-tetanic count at ≤ 1 in the adductor pollicis muscle is essential to prevent the obturator jerk. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  8. A single dose of oxytocin nasal spray improves higher-order social cognition in schizophrenia.

    Science.gov (United States)

    Guastella, Adam J; Ward, Philip B; Hickie, Ian B; Shahrestani, Sara; Hodge, Marie Antoinette Redoblado; Scott, Elizabeth M; Langdon, Robyn

    2015-11-01

    Schizophrenia is associated with significant impairments in both higher and lower order social cognitive performance and these impairments contribute to poor social functioning. People with schizophrenia report poor social functioning to be one of their greatest unmet treatment needs. Recent studies have suggested the potential of oxytocin as such a treatment, but mixed results render it uncertain what aspects of social cognition are improved by oxytocin and, subsequently, how oxytocin might best be applied as a therapeutic. The aim of this study was to determine whether a single dose of oxytocin improved higher-order and lower-order social cognition performance for patients with schizophrenia across a well-established battery of social cognition tests. Twenty-one male patients received both a single dose of oxytocin nasal spray (24IU) and a placebo, two weeks apart in a randomized within-subjects placebo controlled design. Following each administration, participants completed the social cognition tasks, as well as a test of general neurocognition. Results revealed that oxytocin particularly enhanced performance on higher order social cognition tasks, with no effects on general neurocognition. Results for individual tasks showed most improvement on tests measuring appreciation of indirect hints and recognition of social faux pas. These results suggest that oxytocin, if combined to enhance social cognition learning, may be beneficial when targeted at higher order social cognition domains. This study also suggests that these higher order tasks, which assess social cognitive processing in a social communication context, may provide useful markers of response to oxytocin in schizophrenia. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Higher hydrocortisone dose increases bilirubin in hypopituitary patients- results from an RCT.

    Science.gov (United States)

    Werumeus Buning, Jorien; Kootstra-Ros, Jenny E; Brummelman, Pauline; van den Berg, Gerrit; van der Klauw, Melanie; Wolffenbuttel, Bruce H R; van Beek, André P; Dullaart, Robin P F

    2016-05-01

    Bilirubin has anti-oxidative and anti-inflammatory properties, which may explain its proposed protective effects on the development of cardiometabolic disorders. Glucocorticoids affect heme oxygenase regulation in vitro, which plays a key role in bilirubin production. Effects of variations in glucocorticoid exposure on circulating bilirubin levels in humans are unknown. Here we tested whether a higher hydrocortisone replacement dose affects circulating bilirubin in hypopituitary patients. A randomized double-blind cross-over study (ClinicalTrials.gov, number NCT01546992) was performed in 47 patients with secondary adrenal failure [10-week exposure to a higher hydrocortisone dose (0·4-0·6 mg/kg body weight) vs. 10 weeks of a lower hydrocortisone dose (0·2-0·3 mg/kg body weight)]. Plasma total bilirubin was increased by 10% from 7 to 8 μM in response to the higher hydrocortisone dose (P = 0·033). This effect was inversely related to age (P = 0·042), but was unaffected by sex, obesity and (replacement for) other hormonal insufficiencies. The higher hydrocortisone dose also resulted in lower alkaline phosphatase (P = 0·006) and aspartate aminotransferase activities (P = 0·001). Bilirubin is modestly increased in response to higher glucocorticoid exposure in humans, in conjunction with lower alkaline phosphatase and aspartate aminotransferase activities, which are supposed to represent biomarkers of a pro-inflammatory state and enhanced liver fat accumulation. © 2016 The Authors. European Journal of Clinical Investigation published by John Wiley & Sons Ltd on behalf of Stichting European Society for Clinical Investigation Journal Foundation.

  10. Warfarin maintenance dose in older patients: higher average dose and wider dose frequency distribution in patients of African ancestry than those of European ancestry.

    Science.gov (United States)

    Garwood, Candice L; Clemente, Jennifer L; Ibe, George N; Kandula, Vijay A; Curtis, Kristy D; Whittaker, Peter

    2010-06-15

    Studies report that warfarin doses required to maintain therapeutic anticoagulation decrease with age; however, these studies almost exclusively enrolled patients of European ancestry. Consequently, universal application of dosing paradigms based on such evidence may be confounded because ethnicity also influences dose. Therefore, we determined if warfarin dose decreased with age in Americans of African ancestry, if older African and European ancestry patients required different doses, and if their daily dose frequency distributions differed. Our chart review examined 170 patients of African ancestry and 49 patients of European ancestry cared for in our anticoagulation clinic. We calculated the average weekly dose required for each stable, anticoagulated patient to maintain an international normalized ratio of 2.0 to 3.0, determined dose averages for groups 80 years of age and plotted dose as a function of age. The maintenance dose in patients of African ancestry decreased with age (PAfrican ancestry required higher average weekly doses than patients of European ancestry: 33% higher in the 70- to 79-year-old group (38.2+/-1.9 vs. 28.8+/-1.7 mg; P=0.006) and 52% in the >80-year-old group (33.2+/-1.7 vs. 21.8+/-3.8 mg; P=0.011). Therefore, 43% of older patients of African ancestry required daily doses >5mg and hence would have been under-dosed using current starting-dose guidelines. The dose frequency distribution was wider for older patients of African ancestry compared to those of European ancestry (PAfrican ancestry indicate that strategies for initiating warfarin therapy based on studies of patients of European ancestry could result in insufficient anticoagulation and thereby potentially increase their thromboembolism risk. Copyright 2010 Elsevier Inc. All rights reserved.

  11. Higher quantum conserved current in a new completely integrable model

    International Nuclear Information System (INIS)

    Nissimov, E.R.

    1980-06-01

    The first higher local quantum conserved current is the recently proposed new completely integrable (2esup(βphi)+esup(-2βphi)) 2 model is explicitly constructed thus proving absence of particle production and factorization of multiparticle scattering. (author)

  12. Reparative processes in spleen of rats irradiated with higher daily dose rates of continuous irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Mackova, N; Praslicka, M; Misurova, E [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Prirodovedecka Fakulta

    1975-01-01

    Histological and DNA content values were used in evaluating repair processes in the spleen of rats at various intervals following continuous irradiation with daily doses of 50 R, 100 R, 200 R and 500 R (a total dose of 1000 R), and following a single exposure to 1000 R. Histological changes found immediately after irradiation indicated the induction of significant injuries, this mainly as a result of daily doses of 200 R and 500 R. The complete repair of the DNA content and of a number of erythroid elements and also a 70 to 80% regeneration of the white pulp took place within 25 days. The same period was found to be insufficient for the complete repair of megakaryocytes. No signs of repair were observed in spleen in the histological picture or DNA content after a single irradiation with a dose of 1000 R.

  13. Reparative processes in spleen of rats irradiated with higher daily dose rates of continuous irradiation

    International Nuclear Information System (INIS)

    Mackova, N.; Praslicka, M.; Misurova, E.

    1975-01-01

    Histological and DNA content values were used in evaluating repair processes in the spleen of rats at various intervals following continuous irradiation with daily doses of 50 R, 100 R, 200 R and 500 R (a total dose of 1000 R), and following a single exposure to 1000 R. Histological changes found immediately after irradiation indicated the induction of significant injuries, this mainly as a result of daily doses of 200 R and 500 R. The complete repair of the DNA content and of a number of erythroid elements and also a 70 to 80% regeneration of the white pulp took place within 25 days. The same period was found to be insufficient for the complete repair of megakaryocytes. No signs of repair were observed in spleen in the histological picture or DNA content after a single irradiation with a dose of 1000 R. (author)

  14. Higher dose rate Gamma Knife radiosurgery may provide earlier and longer-lasting pain relief for patients with trigeminal neuralgia.

    Science.gov (United States)

    Lee, John Y K; Sandhu, Sukhmeet; Miller, Denise; Solberg, Timothy; Dorsey, Jay F; Alonso-Basanta, Michelle

    2015-10-01

    Gamma Knife radiosurgery (GKRS) utilizes cobalt-60 as its radiation source, and thus dose rate varies as the fixed source decays over its half-life of approximately 5.26 years. This natural decay results in increasing treatment times when delivering the same cumulative dose. It is also possible, however, that the biological effective dose may change based on this dose rate even if the total dose is kept constant. Because patients are generally treated in a uniform manner, radiosurgery for trigeminal neuralgia (TN) represents a clinical model whereby biological efficacy can be tested. The authors hypothesized that higher dose rates would result in earlier and more complete pain relief but only if measured with a sensitive pain assessment tool. One hundred thirty-three patients were treated with the Gamma Knife Model 4C unit at a single center by a single neurosurgeon during a single cobalt life cycle from January 2006 to May 2012. All patients were treated with 80 Gy with a single 4-mm isocenter without blocking. Using an output factor of 0.87, dose rates ranged from 1.28 to 2.95 Gy/min. The Brief Pain Inventory (BPI)-Facial was administered before the procedure and at the first follow-up office visit 1 month from the procedure (mean 1.3 months). Phone calls were made to evaluate patients after their procedures as part of a retrospective study. Univariate and multivariate linear regression was performed on several independent variables, including sex, age in deciles, diagnosis, follow-up duration, prior surgery, and dose rate. In the short-term analysis (mean 1.3 months), patients' self-reported pain intensity at its worst was significantly correlated with dose rate on multivariate analysis (p = 0.028). Similarly, patients' self-reported interference with activities of daily living was closely correlated with dose rate on multivariate analysis (p = 0.067). A 1 Gy/min decrease in dose rate resulted in a 17% decrease in pain intensity at its worst and a 22% decrease

  15. Performance Funding in Higher Education: Do Financial Incentives Impact College Completions?

    Science.gov (United States)

    Hillman, Nicholas W.; Tandberg, David A.; Gross, Jacob P. K.

    2014-01-01

    In 2000, the Pennsylvania State System of Higher Education introduced a performance-based funding model aimed at increasing degree productivity among the state's public colleges. This study examines how the new policy affected undergraduate degree completions. Using a difference-in-differences estimation strategy, results suggest the policy has…

  16. Women Administered Standard Dose Imatinib for Chronic Myeloid Leukemia Have Higher Dose-Adjusted Plasma Imatinib and Norimatinib Concentrations Than Men.

    Science.gov (United States)

    Belsey, Sarah L; Ireland, Robin; Lang, Kathryn; Kizilors, Aytug; Ho, Aloysius; Mufti, Ghulam J; Bisquera, Alessandra; De Lavallade, Hugues; Flanagan, Robert J

    2017-10-01

    The standard dose of imatinib for the treatment of chronic-phase chronic myeloid leukemia (CML) is 400 mg·d. A predose plasma imatinib concentration of >1 mg·L is associated with improved clinical response. This study aimed to assess the plasma imatinib and norimatinib concentrations attained in patients with chronic myeloid leukemia administered standard doses of imatinib adjusted for dose, age, sex, body weight, and response. We evaluated data from a cohort of patients treated between 2008 and 2014 with respect to dose, age, sex, body weight, and response. The study comprised 438 samples from 93 patients (54 male, 39 female). The median imatinib dose was 400 mg·d in men and in women. The plasma imatinib concentration ranged 0.1-5.0 mg·L and was below 1 mg·L in 20% and 16% of samples from men and women, respectively. The mean dose normalized plasma imatinib and norimatinib concentrations were significantly higher in women in comparison with men. This was partially related to body weight. Mixed effects ordinal logistic regression showed no evidence of an association between sex and plasma imatinib (P = 0.13). However, there was evidence of an association between sex and plasma norimatinib, with higher norimatinib concentrations more likely in women than in men (P = 0.02). Imatinib therapeutic drug monitoring only provides information on dosage adequacy and on short-term adherence; longer-term adherence cannot be assessed. However, this analysis revealed that approximately 1 in 5 samples had a plasma imatinib concentration <1 mg·L, which was suggestive of inadequate dosage and/or poor adherence and posed a risk of treatment failure. Higher imatinib exposure in women may be a factor in the increased rate of long-term, stable, deep molecular response (undetectable breakpoint cluster-Abelson (BCR-ABL) transcript levels with a PCR sensitivity of 4.5 log, MR4.5) reported in women.

  17. Dose effect relationships in cervical and thoracic radiation myelopathies

    International Nuclear Information System (INIS)

    Holdorff, B.

    1980-01-01

    The course and prognosis of radiation myelopathies are determined by 3 factors: the segmental (vertical) location of the lesion, the extent of the transverse syndrome (complete or incomplete) and the radiation dose. The median spinal dose in cervical radiation myelopathies with fatal outcome was higher than in survivals with an incomplete transverse syndrome. In thoracic radiation myelopathies a dose difference between complete and incomplete transverse syndromes could be found as well. Incomplete transverse syndromes as submaximum radiation injuries are more suitable for the determination of the spinal tolerance dose than complete transverse syndromes. The lowest threshold could be stated for cases following high-volume irradiation of the lymphatic system. (Auth.)

  18. Higher dose of palonosetron versus lower dose of palonosetron plus droperidol to prevent postoperative nausea and vomiting after eye enucleation and orbital hydroxyapatite implant surgery: a randomized, double-blind trial

    Directory of Open Access Journals (Sweden)

    Hu X

    2017-05-01

    Full Text Available Xiao Hu, Fang Tan, Lan Gong Department of Anesthesiology, The Eye, Ear, Nose and Throat Hospital of Fudan University, Shanghai Medical College of Fudan University, Shanghai, China Objective: Postoperative nausea and vomiting (PONV is commonly observed after eye enucleation and orbital hydroxyapatite implant surgery. This prospective, randomized, double-blind trial was conducted to investigate the hypothesis that compared with monotherapy using a higher dose of palonosetron, using a lower dose of palonosetron in combination with droperidol could reduce the incidence of PONV and achieve similar prophylaxis against PONV after the aforementioned surgery.Patients and methods: A total of 129 patients who were in the American Society of Anesthesiologists Classes I and II, aged between 18 and 70 years, and scheduled for eye enucleation and orbital hydroxyapatite implant surgery, were enrolled in this study. They were randomized into three groups: Group P2.5 (2.5 µg/kg palonosetron, Group P7.5 (7.5 µg/kg palonosetron, and Group P+D (2.5 µg/kg palonosetron and 15 µg/kg droperidol. Patients received the different antiemetic regimens intravenously 5 min before surgery. The severity of nausea and vomiting and the complete response (CR rate during a 72-h postoperative period were assessed.Results: All patients completed the trial. The nausea score of Group P2.5 was significantly higher than those of the other two groups at 0–4 h and 24–48 h (P<0.05. Vomiting scores among all groups were similar during all intervals (P>0.05. Compared with Group P2.5, the CR rate was significantly improved at all intervals in Group P+D, except at 4–72 h, and was also elevated at 24–72 h in Group P7.5 (P<0.05. Fewer patients in Group P2.5 did not experience any nausea or vomiting throughout the study (49% compared with those in Group P7.5 (67% and Group P+D (81%; P<0.01.Conclusion: Combining low-dose palonosetron with droperidol potentiated prophylaxis

  19. Effective dose comparison between protocols stitched and usual protocols in dental cone beam CT for complete arcade

    International Nuclear Information System (INIS)

    Soares, M. R.; Maia, A. F.; Batista, W. O. G.; Lara, P. A.

    2014-08-01

    To visualization a complete dental radiology dental lives together with two separate proposals: [1] protocols diameter encompassing the entire arch (single) or [2] protocol with multiple fields of view (Fov) which together encompass the entire arch (stitched Fov s). The objective of this study is to evaluate effective dose values in examination protocols for all dental arcade available in different outfits with these two options. For this, a female anthropomorphic phantom manufactured by Radiology Support Devices twenty six thermoluminescent dosimeters inserted in relevant bodies and positions was used. Irradiate the simulator in the clinical conditions. The protocols were averaged and compared: [a] 14.0 cm x 8.5 cm and [b] 8.5 cm x 8.5 cm (Gendex Tomography GXCB 500), [c] protocol stitched for jaw combination of three volumes of 5.0 cm x 3.7 cm (Kodak 9000 3D scanner) [d] protocol stitched Fov s 5.0 cm x 8.0 cm (Planmeca Pro Max 3D) and [e] single technical Fov 14 cm x 8 cm (i-CAT Classical). Our results for the effective dose were: a range between 43.1 and 111.1 micro Sv for technical single Fov and 44.5 and 236.2 for technical stitched Fov s. The protocol presented the highest estimated effective dose was [d] and showed that lowest index was registered [a]. These results demonstrate that the protocol stitched Fov generated in Kodak 9000 3D machine applied the upper dental arch has practically equal value effective dose obtained by protocol extended diameter of, [a], which evaluates in a single image upper and lower arcade. It also demonstrates that the protocol [d] gives an estimate of five times higher than the protocol [a]. Thus, we conclude that in practical terms the protocol [c] stitched Fov s, not presents dosimetric advantages over other protocols. (Author)

  20. Effective dose comparison between protocols stitched and usual protocols in dental cone beam CT for complete arcade

    Energy Technology Data Exchange (ETDEWEB)

    Soares, M. R.; Maia, A. F. [Universidade Federal de Sergipe, Departamento de Fisica, Cidade Universitaria Prof. Jose Aloisio de Campos, Marechal Rondon s/n, Jardim Rosa Elze, 49-100000 Sao Cristovao, Sergipe (Brazil); Batista, W. O. G. [Instituto Federal da Bahia, Rua Emidio dos Santos s/n, Barbalho, Salvador, 40301015 Bahia (Brazil); Lara, P. A., E-mail: wilsonottobatista@gmail.com [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    To visualization a complete dental radiology dental lives together with two separate proposals: [1] protocols diameter encompassing the entire arch (single) or [2] protocol with multiple fields of view (Fov) which together encompass the entire arch (stitched Fov s). The objective of this study is to evaluate effective dose values in examination protocols for all dental arcade available in different outfits with these two options. For this, a female anthropomorphic phantom manufactured by Radiology Support Devices twenty six thermoluminescent dosimeters inserted in relevant bodies and positions was used. Irradiate the simulator in the clinical conditions. The protocols were averaged and compared: [a] 14.0 cm x 8.5 cm and [b] 8.5 cm x 8.5 cm (Gendex Tomography GXCB 500), [c] protocol stitched for jaw combination of three volumes of 5.0 cm x 3.7 cm (Kodak 9000 3D scanner) [d] protocol stitched Fov s 5.0 cm x 8.0 cm (Planmeca Pro Max 3D) and [e] single technical Fov 14 cm x 8 cm (i-CAT Classical). Our results for the effective dose were: a range between 43.1 and 111.1 micro Sv for technical single Fov and 44.5 and 236.2 for technical stitched Fov s. The protocol presented the highest estimated effective dose was [d] and showed that lowest index was registered [a]. These results demonstrate that the protocol stitched Fov generated in Kodak 9000 3D machine applied the upper dental arch has practically equal value effective dose obtained by protocol extended diameter of, [a], which evaluates in a single image upper and lower arcade. It also demonstrates that the protocol [d] gives an estimate of five times higher than the protocol [a]. Thus, we conclude that in practical terms the protocol [c] stitched Fov s, not presents dosimetric advantages over other protocols. (Author)

  1. Low submetamorphic doses of dexamethasone and thyroxine induce complete metamorphosis in the axolotl (Ambystoma mexicanum) when injected together.

    Science.gov (United States)

    Kühn, Eduard R; De Groef, Bert; Grommen, Sylvia V H; Van der Geyten, Serge; Darras, Veerle M

    2004-06-01

    Entanglement of functions between the adrenal (or interrenal) and thyroid axis has been well described for all vertebrates and can be tracked down up to the level of gene expression. Both thyroid hormones and corticosteroids may induce morphological changes leading to metamorphosis climax in the neotenic Mexican axolotl (Ambystoma mexicanum). In a first series of experiments, metamorphosis was induced with an injection of 25 microg T(4) on three alternate days as judged by a decrease in body weight and tail height together with complete gill resorption. This injection also resulted in elevated plasma concentrations of T(3) and corticosterone. Previous results have indicated that the same dose of dexamethasone (DEX) is ineffective in this regard (Gen. Comp. Endocrinol. 127 (2002) 157). In a second series of experiments low doses of T(4) (0.5 microg) or DEX (5 microg) were ineffective to induce morphological changes. However, when these submetamorphic doses were injected together, morphological changes were observed within one week leading to complete metamorphosis. It is concluded that thyroid hormones combined with corticosteroids are essential for metamorphosis in the axolotl and that only high doses of either thyroid hormone or corticosteroid can induce morphological changes when injected separately.

  2. Bioavailability of higher dose methotrexate comparing oral and subcutaneous administration in patients with rheumatoid arthritis

    NARCIS (Netherlands)

    Hoekstra, Monique; Haagsma, C.; Neef, C; Proost, Johannes H; Knuif, A.; van der Laar, M.

    Objective. To determine the bioavailability of higher oral doses of methotrexate (MTX) in adult patients with rheumatoid arthritis (RA). Methods. A pharmacokinetic analysis was performed in 15 patients with RA taking a stable dose of MTX (greater than or equal to25 mg weekly). Separated by 2 weeks,

  3. Effects of low doses of caffeine on cognitive performance, mood and thirst in low and higher caffeine consumers.

    Science.gov (United States)

    Smit, H J; Rogers, P J

    2000-10-01

    Caffeine is present in many widely consumed drinks and some foods. In the fairly extensive literature on the psychostimulant effects of caffeine, there are few dose-response studies and even fewer studies of the effects of doses of caffeine lower than 50 mg (the range of the amounts of caffeine contained in, for example, a typical serving of tea or cola). This study measured the effects of 0, 12.5, 25, 50 and 100 mg caffeine on cognitive performance, mood and thirst in adults with low and moderate to high habitual caffeine intakes. This was a double-blind, within-subjects study. Following overnight caffeine abstinence, participants (n=23) completed a test battery once before and three times after placebo or caffeine administration. The test battery consisted of two performance tests, a long duration simple reaction time task and a rapid visual information processing task, and a mood questionnaire (including also an item on thirst). Effects on performance and mood confirmed a psychostimulant action of caffeine. All doses of caffeine significantly affected cognitive performance, and the dose-response relationships for these effects were rather flat. The effects on performance were more marked in individuals with a higher level of habitual caffeine intake, whereas caffeine increased thirst only in low caffeine consumers. After overnight caffeine abstinence, caffeine can significantly affect cognitive performance, mood and thirst at doses within and even lower than the range of amounts of caffeine contained in a single serving of popular caffeine-containing drinks. Regular caffeine consumers appear to show substantial tolerance to the thirst-increasing but not to the performance and mood effects of caffeine.

  4. Assessment of individual dose utilization vs. physician prescribing recommendations for recombinant activated factor VII (rFVIIa) in paediatric and adult patients with congenital haemophilia and alloantibody inhibitors (CHwI): the Dosing Observational Study in Hemophilia (DOSE).

    Science.gov (United States)

    Gruppo, R A; Kessler, C M; Neufeld, E J; Cooper, D L

    2013-07-01

    Recent data from the Dosing Observational Study in Hemophilia diary study has described home treatment with recombinant activated factor VII (rFVIIa) in congenital haemophilia with inhibitors (CHwI). The current analysis compares prescribed and patient/caregiver-reported rFVIIa administration in paediatric and adult CHwI patients in this study. Patients with ≥ 4 bleeding episodes within a 3-month period prescribed rFVIIa as first-line therapy for bleeding episodes were eligible. Patients/caregivers completed a diary for ≥ 90 days or until the patient experienced four bleeds. Initial, total and mean rFVIIa doses reported for each bleeding episode were calculated and compared with the physician-prescribed doses. Of 52 enrolled patients (25 children; 27 adults), 39 (75%) completed the study. Children and adults had similar mean durations of bleeding episodes. Both patient groups were administered higher initial rFVIIa doses for joint bleeds than prescribed: median (range) 215.2 (74.1-400.0) mcg kg(-1) vs. 200.0 (61.0-270.0) mcg kg(-1) for children, and 231.3 (59.3-379.7) mcg kg(-1) vs. 123.0 (81.0-289.0) mcg kg(-1) for adults. The median infused dose for joint bleeds was higher in adults than children (175.2 vs. 148.0 mcg kg(-1) ), but children received significantly more doses per joint bleed than adults (median 6.5 vs. 3.0). The median total dose per joint bleed was higher in children than adults (1248.7 vs. 441.6). For children and adults, both initial and additional doses administered for bleeds were higher than prescribed. Children received higher total doses per bleed due to an increased number of infusions per bleed. © 2013 John Wiley & Sons Ltd.

  5. Fully automated treatment planning for head and neck radiotherapy using a voxel-based dose prediction and dose mimicking method

    Science.gov (United States)

    McIntosh, Chris; Welch, Mattea; McNiven, Andrea; Jaffray, David A.; Purdie, Thomas G.

    2017-08-01

    Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment

  6. Higher glucocorticoid replacement doses are associated with increased mortality in patients with pituitary adenoma.

    Science.gov (United States)

    Hammarstrand, Casper; Ragnarsson, Oskar; Hallén, Tobias; Andersson, Eva; Skoglund, Thomas; Nilsson, Anna G; Johannsson, Gudmundur; Olsson, Daniel S

    2017-09-01

    Patients with secondary adrenal insufficiency (AI) have an excess mortality. The objective was to investigate the impact of the daily glucocorticoid replacement dose on mortality in patients with hypopituitarism due to non-functioning pituitary adenoma (NFPA). Patients with NFPA were followed between years 1997 and 2014 and cross-referenced with the National Swedish Death Register. Standardized mortality ratio (SMR) was calculated with the general population as reference and Cox-regression was used to analyse the mortality. The analysis included 392 patients (140 women) with NFPA. Mean ± s.d. age at diagnosis was 58.7 ± 14.6 years and mean follow-up was 12.7 ± 7.2 years. AI was present in 193 patients, receiving a mean daily hydrocortisone equivalent (HCeq) dose of 20 ± 6 mg. SMR (95% confidence interval (CI)) for patients with AI was similar to that for patients without, 0.88 (0.68-1.12) and 0.87 (0.63-1.18) respectively. SMR was higher for patients with a daily HCeq dose of >20 mg (1.42 (0.88-2.17)) than that in patients with a daily HCeq dose of 20 mg (0.71 (0.49-0.99)), P  = 0.017. In a Cox-regression analysis, a daily HCeq dose of >20 mg was independently associated with a higher mortality (HR: 1.88 (1.06-3.33)). Patients with daily HCeq doses of ≤20 mg had a mortality risk comparable to patients without glucocorticoid replacement and to the general population. Patients with NFPA and AI receiving more than 20 mg HCeq per day have an increased mortality. Our data also show that mortality in patients substituted with 20 mg HCeq per day or less is not increased. © 2017 European Society of Endocrinology.

  7. Evaluating higher doses of Shunthi - Guduchi formulations for safety in treatment of osteoarthritis knees: A Government of India NMITLI arthritis project.

    Science.gov (United States)

    Chopra, Arvind; Saluja, Manjit; Tillu, Girish; Venugopalan, Anuradha; Narsimulu, Gumdal; Sarmukaddam, Sanjeev; Patwardhan, Bhushan

    2012-01-01

    Results of an exploratory trial suggested activity trends of Zingiber officinale-Tinopsora cordifolia (platform combination)-based formulations in the treatment of Osteoarthritis (OA) Knees. These formulations were "platform combination+Withania somnifera+Tribulus terrestris" (formulation B) and "platform combination+Emblica officinale" (formulation C). This paper reports safety of these formulations when used in higher doses (1.5-2 times) along with Sallaki Guggul and Bhallataka Parpati (a Semecarpus anacardium preparation). Ninety-two patients with symptomatic OA knees were enrolled in a 6 weeks investigator blind, randomized parallel efficacy 4-arm multicenter drug trial. The 4 arms were (I) formulation B, 2 t.i.d.; (II) formulation B, 2 q.i.d.; (III) platform combination+Sallaki Guggul; (IV) Bhallataka Parpati+formulation C. A detailed enquiry was carried out for adverse events (AE) and drug toxicity as per a priori check list and volunteered information. Laboratory evaluation included detailed hematology and metabolic parameters. Patients were examined at baseline, first and fourth weeks, and on completion. Standard statistical program (SPSS version 12.5) was used for analysis. None of the patients reported serious AE or withdrew due to any drug-related toxicity. Mild gut-related (mostly epigastric burning) AE was reported. A mild increase in liver enzymes [serum glutamic pyruvate transaminase (SGPT), serum glutamic oxaloacetic transaminase (SGOT)] without any other hepatic abnormality was reported in 2 patients (group IV). Other laboratory parameters remained normal. The mean improvement in active pain visual analog scale (1.4, CI 0.5-2.22), WOMAC (functional activity questionnaire) pain score (1.37, CI 0.22-2.5), and urinary C-TAX (cartilage collagen breakdown product) assay was maximum (NS) in group IV. Lower dose group I showed numerically superior improvement compared with higher dose group II. The results suggested that despite higher doses, standardized

  8. Using higher doses to compensate for tubing residuals in extended-infusion piperacillin-tazobactam.

    Science.gov (United States)

    Lam, Wendy J; Bhowmick, Tanaya; Gross, Alan; Vanschooneveld, Trevor C; Weinstein, Melvin P

    2013-06-01

    To mathematically assess drug losses due to infusion line residuals and evaluate methods to compensate for drug loss due to residual volumes in intravenous pump tubing. Literature was accessed through Ovid MEDLINE (1996-February 2013), using combinations of the search terms tubing residuals, residual volume, residual medication, intravenous infusions, intravenous injections, piperacillin, piperacillin-tazobactam, β-lactams, equipment design, infusion pumps, extended infusion, extended administration, and prolonged infusion. In addition, select reference citations from publications identified were reviewed. All articles that involved extended-infusion piperacillin-tazobactam implementation strategies were included in the review. Infusion pump characteristics and tubing residuals can affect extended-infusion piperacillin-tazobactam dosing strategies. Two studies addressing tubing residuals were identified. Both studies recommended increasing infusion volumes to compensate for tubing residuals. One study also recommended decreasing infusion-line dead space by using alternative infusion pump systems. Study calculations suggest that higher doses of piperacillin-tazobactam may be used to account for medication left in tubing residuals if alternative infusion pump systems cannot be obtained, and increased infusion volumes are not an option. Extended-infusion piperacillin-tazobactam has been used as a method of maximizing pharmacodynamic target attainment. Use of higher doses of piperacillin-tazobactam may be a reasonable method to compensate for drug loss due to residual volumes in large-bore intravenous pump tubing.

  9. Factors associated with higher oxytocin requirements in labor.

    Science.gov (United States)

    Frey, Heather A; Tuuli, Methodius G; England, Sarah K; Roehl, Kimberly A; Odibo, Anthony O; Macones, George A; Cahill, Alison G

    2015-09-01

    To identify clinical characteristics associated with high maximum oxytocin doses in women who achieve complete cervical dilation. A retrospective nested case-control study was performed within a cohort of all term women at a single center between 2004 and 2008 who reached the second stage of labor. Cases were defined as women who had a maximum oxytocin dose during labor >20 mu/min, while women in the control group had a maximum oxytocin dose during labor of ≤20 mu/min. Exclusion criteria included no oxytocin administration during labor, multiple gestations, major fetal anomalies, nonvertex presentation, and prior cesarean delivery. Multiple maternal, fetal, and labor factors were evaluated with univariable analysis and multivariable logistic regression. Maximum oxytocin doses >20 mu/min were administered to 108 women (3.6%), while 2864 women received doses ≤20 mu/min. Factors associated with higher maximum oxytocin dose after adjusting for relevant confounders included maternal diabetes, birthweight >4000 g, intrapartum fever, administration of magnesium, and induction of labor. Few women who achieve complete cervical dilation require high doses of oxytocin. We identified maternal, fetal and labor factors that characterize this group of parturients.

  10. Bioavailibility of higher dose methotrexate comparing oral and subcutaneous route of administration in patients with rheumatoid arthritis

    NARCIS (Netherlands)

    Hoekstra, Monique; Hoekstra, M.; Haagsma, Cees; Neef, Cees; Proost, Johannes; van de Laar, Mart A F J; Knuif, Antonius

    2004-01-01

    OBJECTIVE: To determine the bioavailability of higher oral doses of methotrexate (MTX) in adult patients with rheumatoid arthritis (RA). METHODS: A pharmacokinetic analysis was performed in 15 patients with RA taking a stable dose of MTX (> or = 25 mg weekly). Separated by 2 weeks, a pharmacokinetic

  11. Consolidation Radiotherapy in Primary Central Nervous System Lymphomas: Impact on Outcome of Different Fields and Doses in Patients in Complete Remission After Upfront Chemotherapy

    International Nuclear Information System (INIS)

    Ferreri, Andres Jose Maria; Verona, Chiara; Politi, Letterio Salvatore; Chiara, Anna; Perna, Lucia; Villa, Eugenio; Reni, Michele

    2011-01-01

    Purpose: Avoidance radiotherapy or reduction of irradiation doses in patients with primary central nervous system lymphoma (PCNSL) in complete remission (CR) after high-dose methotrexate (HD-MTX)-based chemotherapy has been proposed to minimize the neurotoxicity risk. Nevertheless, no study has focused on the survival impact of radiation parameters, as far as we know, and the optimal radiation schedule remains to be defined. Methods and Materials: The impact on outcome and neurologic performance of different radiation fields and doses was assessed in 33 patients with PCNSL who achieved CR after MTX-containing chemotherapy and were referred to consolidation whole-brain irradiation (WBRT). Patterns of relapse were analyzed on computed tomography-guided treatment planning, and neurologic impairment was assessed by the Mini Mental Status Examination. Results: At a median follow-up of 50 months, 21 patients are relapse-free (5-year failure-free survival [FFS], 51%). WBRT doses ≥40 Gy were not associated with improved disease control in comparison with a WBRT dose of 30 to 36 Gy (relapse rate, 46% vs. 30%; 5-year FFS, 51% vs. 50%; p = 0.26). Disease control was not significantly different between patients irradiated to the tumor bed with 45 to 54 Gy or with 36 to 44 Gy, with a 5-year FFS of 35% and 44% (p = 0.43), respectively. Twenty patients are alive (5-year overall survival, 54%); WB and tumor bed doses did not have an impact on survival. Impairment as assessed by the Mini Mental Status Examination was significantly more common in patients treated with a WBRT dose ≥40 Gy. Conclusion: Consolidation with WBRT 36 Gy is advisable in patients with PCNSL in CR after HD-MTX-based chemotherapy. Higher doses do not change the outcome and could increase the risk of neurotoxicity.

  12. Maximizing the Benefit-Cost Ratio of Anthracyclines in Metastatic Breast Cancer: Case Report of a Patient with a Complete Response to High-Dose Doxorubicin

    Directory of Open Access Journals (Sweden)

    Kevin Shee

    2016-12-01

    Full Text Available Despite the clinical efficacy of anthracycline agents such as doxorubicin, dose-limiting cardiac toxicities significantly limit their long-term use. Here, we present the case of a 33-year-old female patient with extensive metastatic ER+/PR+/HER2– mucinous adenocarcinoma of the breast, who was started on doxorubicin/cyclophosphamide therapy after progressing on paclitaxel and ovarian suppressor goserelin with aromatase inhibitor exemestane. The patient was comanaged by cardiology, who carefully monitored measures of cardiac function, including EKGs, serial echocardiograms, and profiling of lipids, troponin, and pro-BNP every 2 months. The patient was treated with the cardioprotective agent dexrazoxane, and changes in cardiac markers [e.g. decreases in ejection fraction (EF] were immediately addressed by therapeutic intervention with the ACE inhibitor lisinopril and beta-blocker metoprolol. The patient had a complete response to doxorubicin therapy, with a cumulative dose of 1,350 mg/m2, which is significantly above the recommended limits, and to our knowledge, the highest dose reported in literature. Two and a half years after the last doxorubicin cycle, the patient is asymptomatic with no cardiotoxicity and an excellent quality of life. This case highlights the importance of careful monitoring and management of doxorubicin-mediated cardiotoxicity, and that higher cumulative doses of anthracyclines can be considered in patients with ongoing clinical benefit.

  13. Effects of a higher dose of near-infrared light on clinical signs and neuroprotection in a monkey model of Parkinson's disease.

    Science.gov (United States)

    Moro, Cécile; El Massri, Nabil; Darlot, Fannie; Torres, Napoleon; Chabrol, Claude; Agay, Diane; Auboiroux, Vincent; Johnstone, Daniel M; Stone, Jonathan; Mitrofanis, John; Benabid, Alim-Louis

    2016-10-01

    We have reported previously that intracranial application of near-infrared light (NIr) - when delivered at the lower doses of 25J and 35J - reduces clinical signs and offers neuroprotection in a subacute MPTP (1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine) monkey model of Parkinson's disease. In this study, we explored whether a higher NIr dose (125J) generated beneficial effects in the same MPTP monkey model (n=15). We implanted an NIr (670nm) optical fibre device within a midline region of the midbrain in macaque monkeys, close to the substantia nigra of both sides. MPTP injections (1.8-2.1mg/kg) were made over a five day period, during which time the NIr device was turned on and left on continuously throughout the ensuing three week survival period. Monkeys were evaluated clinically and their brains processed for immunohistochemistry and stereology. Our results showed that the higher NIr dose did not have any toxic impact on cells at the midbrain implant site. Further, this NIr dose resulted in a higher number of nigral tyrosine hydroxylase immunoreactive cells when compared to the MPTP group. However, the higher NIr dose monkeys showed little evidence for an increase in mean clinical score, number of nigral Nissl-stained cells and density of striatal tyrosine hydroxylase terminations. In summary, the higher NIr dose of 125J was not as beneficial to MPTP-treated monkeys as compared to the lower doses of 25J and 35J, boding well for strategies of NIr dose delivery and device energy consumption in a future clinical trial. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Evaluating higher doses of Shunthi - Guduchi formulations for safety in treatment of osteoarthritis knees: A Government of India NMITLI arthritis project

    Directory of Open Access Journals (Sweden)

    Arvind Chopra

    2012-01-01

    Full Text Available Background: Results of an exploratory trial suggested activity trends of Zingiber officinale-Tinopsora cordifolia (platform combination-based formulations in the treatment of Osteoarthritis (OA Knees. These formulations were "platform combination+Withania somnifera+Tribulus terrestris0" (formulation B and "platform combination+Emblica officinale" (formulation C. This paper reports safety of these formulations when used in higher doses (1.5-2 times along with Sallaki Guggul and Bhallataka Parpati (a Semecarpus anacardium preparation. Materials and Methods: Ninety-two patients with symptomatic OA knees were enrolled in a 6 weeks investigator blind, randomized parallel efficacy 4-arm multicenter drug trial. The 4 arms were (I formulation B, 2 t.i.d.; (II formulation B, 2 q.i.d.; (III platform combination+Sallaki Guggul; (IV Bhallataka Parpati+formulation C. A detailed enquiry was carried out for adverse events (AE and drug toxicity as per a priori check list and volunteered information. Laboratory evaluation included detailed hematology and metabolic parameters. Patients were examined at baseline, first and fourth weeks, and on completion. Standard statistical program (SPSS version 12.5 was used for analysis. Results: None of the patients reported serious AE or withdrew due to any drug-related toxicity. Mild gut-related (mostly epigastric burning AE was reported. A mild increase in liver enzymes [serum glutamic pyruvate transaminase (SGPT, serum glutamic oxaloacetic transaminase (SGOT] without any other hepatic abnormality was reported in 2 patients (group IV. Other laboratory parameters remained normal. The mean improvement in active pain visual analog scale (1.4, CI 0.5-2.22, WOMAC (functional activity questionnaire pain score (1.37, CI 0.22-2.5, and urinary C-TAX (cartilage collagen breakdown product assay was maximum (NS in group IV. Lower dose group I showed numerically superior improvement compared with higher dose group II. Conclusion: The

  15. Distinct Signaling Pathways After Higher or Lower Doses of Radiation in Three Closely Related Human Lymphoblast Cell Lines

    International Nuclear Information System (INIS)

    Lu, T.-P.; Lai, L.-C.; Lin, B.-I.; Chen, L.-H.; Hsiao, T.-H.; Liber, Howard L.; Cook, John A.; Mitchell, James B.; Tsai, M.-H.; Chuang, Eric Y.

    2010-01-01

    Purpose: The tumor suppressor p53 plays an essential role in cellular responses to DNA damage caused by ionizing radiation; therefore, this study aims to further explore the role that p53 plays at different doses of radiation. Materials and Methods: The global cellular responses to higher-dose (10 Gy) and lower dose (iso-survival dose, i.e., the respective D0 levels) radiation were analyzed using microarrays in three human lymphoblast cell lines with different p53 status: TK6 (wild-type p53), NH32 (p53-null), and WTK1 (mutant p53). Total RNAs were extracted from cells harvested at 0, 1, 3, 6, 9, and 24 h after higher and lower dose radiation exposures. Template-based clustering, hierarchical clustering, and principle component analysis were applied to examine the transcriptional profiles. Results: Differential expression profiles between 10 Gy and iso-survival radiation in cells with different p53 status were observed. Moreover, distinct gene expression patterns were exhibited among these three cells after 10 Gy radiation treatment, but similar transcriptional responses were observed in TK6 and NH32 cells treated with iso-survival radiation. Conclusions: After 10 Gy radiation exposure, the p53 signaling pathway played an important role in TK6, whereas the NFkB signaling pathway appeared to replace the role of p53 in WTK1. In contrast, after iso-survival radiation treatment, E2F4 seemed to play a dominant role independent of p53 status. This study dissected the impacts of p53, NFkB and E2F4 in response to higher or lower doses of γ-irradiation.

  16. Medium doses of daily vitamin D decrease falls and higher doses of daily vitamin D3 increase falls: A randomized clinical trial.

    Science.gov (United States)

    Smith, Lynette M; Gallagher, J Christopher; Suiter, Corinna

    2017-10-01

    Falls are a serious health problem in the aging population. Because low levels of vitamin D have been associated with increased fall rates, many trials have been performed with vitamin D; two meta-analyses showed either a small effect or no effect of vitamin D on falls. We conducted a study of the effect of vitamin D on serum 25 hydroxyvitamin D (25OHD) and data on falls was collected as a secondary outcome. In a 12-month double blind randomized placebo trial, elderly women, mean age 66 years, were randomized to one of seven daily oral doses of vitamin D or placebo. The main inclusion criterion for study was a baseline serum 25OHDvitamin D on falls followed a U-shaped curve whether analyzed by dose or serum 25OHD levels. There was no decrease in falls on low vitamin D doses 400, 800 IU, a significant decrease on medium doses 1600, 2400,3200 IU (p=0.020) and no decrease on high doses 4000, 4800 IU compared to placebo (p=0.55). When compared to 12-month serum 25OHD quintiles, the faller rate was 60% in the lowest quintile <25ng/ml (<50nmol/L), 21% in the low middle quintile 32-38ng/ml (80-95nmo/L), 72% in the high middle quintile 38-46ng/ml (95-115nmo/L) and 45% in the highest quintile 46-66ng/ml (115-165nmol/L). In the subgroup with a fall history, fall rates were 68% on low dose, 27% on medium doses and 100% on higher doses. Fall rates on high doses were increased compared to medium doses (Odds Ratio 5.6.95% CI: 2.1-14.8). In summary, the maximum decrease in falls corresponds to a 12- month serum 25OHD of 32-38ng/ml (80-95nmol/L) and faller rates increase as serum 25OHD exceed 40-45ng/ml (100-112.5nmol/L). The Tolerable upper limit (TUL) recently increased in 2010 from 2000 to 4000 IU/day may need to be reduced in elderly women especially in those with a fall history. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Resistances to Scientific Knowledge Production of Comparative Measurements of Dropout and Completion in European Higher Education

    Science.gov (United States)

    Carlhed, Carina

    2017-01-01

    The article is a critical sociological analysis of current transnational practices on creating comparable measurements of dropout and completion in higher education and the consequences for the conditions of scientific knowledge production on the topic. The analysis revolves around questions of epistemological, methodological and symbolic types…

  18. Assessment of low-dose radiotoxicity in microorganisms and higher organisms

    International Nuclear Information System (INIS)

    Obeid, Muhammad Hassan

    2016-01-01

    This work was dedicated to quantify and distinguish the radio- and chemitoxic effects of environmentally relevant low doses of uranium on the metabolism of microorganisms and multicellular organisms by a modern and highly sensitive microcalorimetry. In such low-dose regime, lethality is low or absent. Therefore, quantitative assays based on survival curves cannot be employed, particularly for multicellular organisms. Even in the case of microbial growth, where individual cells may be killed by particle radiation, classical toxicity assessments based on colony counting are not only extremely time-consuming but also highly error-prone. Therefore, measuring the metabolic activity of the organism under such kinds of conditions would give an extremely valuable quantitative measure of viability that is based on life cell monitoring, rather than determining lethality at higher doses and extrapolating it to the low dose regime. The basic concept is simple as it relies on the metabolic heat produced by an organism during development, growth or replication as an inevitable byproduct of all biochemical processes. A metabolic effect in this concept is defined as a change in heat production over time in the presence of a stressor, such as a heavy metal. This approach appeared to be particular versatile for the low dose regime. Thus, the thesis attempted in this case to measure the enthalpy production of a bacterial population as a whole to derive novel toxicity concepts. In the following chapters, an introduction about the properties of ionizing radiation will be briefly presented, in addition to a review about the isothermal calorimetry and its application in studying the bacterial growth. Later in chapter 2, the effect of uranium on the metabolic activity of three different bacterial strains isolated form a uranium mining waste pile together with a reference strain that is genetically related to them will be investigated. Due to the lack of published dedicated calibration

  19. Assessment of low-dose radiotoxicity in microorganisms and higher organisms

    Energy Technology Data Exchange (ETDEWEB)

    Obeid, Muhammad Hassan

    2016-01-11

    This work was dedicated to quantify and distinguish the radio- and chemitoxic effects of environmentally relevant low doses of uranium on the metabolism of microorganisms and multicellular organisms by a modern and highly sensitive microcalorimetry. In such low-dose regime, lethality is low or absent. Therefore, quantitative assays based on survival curves cannot be employed, particularly for multicellular organisms. Even in the case of microbial growth, where individual cells may be killed by particle radiation, classical toxicity assessments based on colony counting are not only extremely time-consuming but also highly error-prone. Therefore, measuring the metabolic activity of the organism under such kinds of conditions would give an extremely valuable quantitative measure of viability that is based on life cell monitoring, rather than determining lethality at higher doses and extrapolating it to the low dose regime. The basic concept is simple as it relies on the metabolic heat produced by an organism during development, growth or replication as an inevitable byproduct of all biochemical processes. A metabolic effect in this concept is defined as a change in heat production over time in the presence of a stressor, such as a heavy metal. This approach appeared to be particular versatile for the low dose regime. Thus, the thesis attempted in this case to measure the enthalpy production of a bacterial population as a whole to derive novel toxicity concepts. In the following chapters, an introduction about the properties of ionizing radiation will be briefly presented, in addition to a review about the isothermal calorimetry and its application in studying the bacterial growth. Later in chapter 2, the effect of uranium on the metabolic activity of three different bacterial strains isolated form a uranium mining waste pile together with a reference strain that is genetically related to them will be investigated. Due to the lack of published dedicated calibration

  20. Patients with Posttraumatic Stress Disorder with Comorbid Major Depressive Disorder Require a Higher Dose of Psychotropic Drugs.

    Science.gov (United States)

    Chiba, Hiromi; Oe, Misari; Uchimura, Naohisa

    2016-01-01

    Major depressive disorder (MDD) has been associated with stressful life events and with posttraumatic stress disorder (PTSD). PTSD and MDD comorbidity was also reported to be associated with greater symptom severity and lower levels of functioning. However, the characteristics of pharmacotherapy for PTSD with MDD are not fully understood. To understand this relationship, we conducted a retrospective review using medical charts at the Department of Neuropsychiatry, Kurume University Hospital. Information from 55 patients with PTSD was analyzed. Five cases were excluded after re-evaluation of the PTSD diagnosis. A higher rate of type II trauma was observed in the PTSD with MDD group (50.0%) than in the PTSD-only group [13.6%; χ(2) (1, n =50) = 7.26, p<0.01]. Patients with comorbid MDD were significantly older, had more severe PTSD symptomatology, and a longer duration of treatment. They also received higher doses of psychotropic drugs, regardless of the type (antidepressants, antipsychotics, benzodiazepines), than the PTSD-only group. Our results showed that comorbid MDD is associated with higher doses of psychotropic drugs, suggesting difficulties in treatment.

  1. Conformal technique dose escalation in prostate cancer: improved cancer control with higher doses in patients with pretreatment PSA {>=} 10 ngm/ml

    Energy Technology Data Exchange (ETDEWEB)

    Hanks, G E; Lee, W R; Hanlon, A L; Kaplan, E; Epstein, B; Schultheiss, T

    1995-07-01

    Purpose: Single institutions and an NCI supported group of institutions have been investigating the value of dose escalation in patients with prostate cancer treated by conformal treatment techniques. Improvement in morbidity has been previously established, while this report identifies the pretreatment PSA level subgroups of patients who benefitted in cancer control from higher dose. Materials and Methods: We report actuarial bNED survival rates for 375 consecutive patients with known pretreatment PSA levels treated with conformal technique between 5/89 and 12/93. The whole pelvis was treated to 45 Gy in 25 fractions in all T2C,3, all Gleason 8, 9, 10 and all patients with pretreatment PSA {>=}20. The prostate {+-} seminal vesicles was boosted at 2.1 Gy/day to the center of the prostate to 65-79 Gy (65-69 N=50), 70-72.49 N=94, 72.5-74.9 N=82, 75-77.49 N=129 and {>=}77.5 N=20). The median followup is 21 mos with a range of 3 to 67 mos. The highest dose patients have the least followup, reducing the impact of the highest dose levels at this time. Patients are analyzed for the entire group divided at 71 Gy and at 73 Gy calculated at the center of the prostate. Each dose group is then subdivided by pretreatment PSA levels <10, 10-19.9, and {>=}20 ngm/ml and dose levels are compared within pretreatment PSA level group. bNED failure is defined as PSA {>=}1.5 ngm/ml and rising on two consecutive values. Results: Table 1 shows the bNED survival rates at 24 and 36 mos for all patients and the three pretreatment PSA level groups. For all patients pooled, there is an overall advantage to using doses {>=}71 Gy (64% vs 85% at 36 mo, p=.006) and {>=}73 Gy (71% vs 86% at 36 mo, p=.07). The subgroup of PSA <10 ngm/ml, however, shows no benefit in bNED survival when using doses over 71 Gy (90% vs 93% at 36 mo) or 73 Gy (91 vs 94% at 36 mo). The subgroup PSA 10 ngm/ml to 19.9 ngm/ml shows improved cancer control when using doses over 71 Gy (61% vs 88% at 36 mo, p=.03) and over 73

  2. Broader Considerations of Higher Doses of Donepezil in the Treatment of Mild, Moderate, and Severe Alzheimer's Disease

    Directory of Open Access Journals (Sweden)

    Camryn Berk

    2012-01-01

    Full Text Available Donepezil, a highly selective acetylcholinesterase inhibitor (AChEI, is approved as a symptomatic treatment mild, moderate, and severe Alzheimer's disease (AD. Donepezil exerts its treatment effect through multiple mechanisms of action including nicotinic receptor stimulation, mitigation of excitotoxicity, and influencing APP processing. The use of donepezil at higher doses is justified given the worsening cholinergic deficit as the disease advances. Donepezil has been investigated in several clinical trials of subjects with moderate-to-severe AD. While the side effects are class specific (cholinergically driven, demonstrable benefit has been shown at the 10 mg dose and the 23 mg doses. Here, we review the clinical justification, efficacy, safety, and tolerability of use of donepezil in the treatment of moderate-to-severe AD.

  3. A Phase I Study of the Safety and Pharmacokinetics of Higher-Dose Icotinib in Patients With Advanced Non-Small Cell Lung Cancer.

    Science.gov (United States)

    Liu, Jian; Wu, Lihua; Wu, Guolan; Hu, Xingjiang; Zhou, Huili; Chen, Junchun; Zhu, Meixiang; Xu, Wei; Tan, Fenlai; Ding, Lieming; Wang, Yinxiang; Shentu, Jianzhong

    2016-11-01

    This phase I study evaluated the maximum tolerated dose, dose-limiting toxicities, safety, pharmacokinetics, and efficacy of icotinib with a starting dose of 250 mg in pretreated, advanced non-small cell lung cancer patients. We observed a maximum tolerated dose of 500 mg with a favorable pharmacokinetics profile and antitumor activity.These findings provide clinicians with evidence for application of higher-dose icotinib. Icotinib, an oral epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor, has shown favorable tolerability and antitumor activity at 100-200 mg in previous studies without reaching the maximum tolerated dose (MTD). In July 2011, icotinib was approved by the China Food and Drug Administration at a dose of 125 mg three times daily for the treatment of patients with locally advanced or metastatic non-small cell lung cancer (NSCLC) after failure of at least one platinum-based chemotherapy regimen. This study investigated the MTD, tolerability, and pharmacokinetics of higher-dose icotinib in patients with advanced NSCLC. Twenty-six patients with advanced NSCLC were treated at doses of 250-625 mg three times daily The EGFR mutation test was not mandatory in this study. Twenty-four (92.3%) of 26 patients experienced at least one adverse event (AE); rash (61.5%), diarrhea (23.1%), and oral ulceration (11.5%) were most frequent AEs. Dose-limiting toxicities were seen in 2 of 6 patients in the 625-mg group, and the MTD was established at 500 mg. Icotinib was rapidly absorbed and eliminated. The amount of time that the drug was present at the maximum concentration in serum (T max ) ranged from 1 to 3 hours (1.5-4 hours) after multiple doses. The t 1/2 was similar after single- and multiple-dose administration (7.11 and 6.39 hours, respectively). A nonlinear relationship was observed between dose and drug exposure. Responses were seen in 6 (23.1%) patients, and 8 (30.8%) patients had stable disease. This study demonstrated that higher-dose

  4. Dose sculpting with generalized equivalent uniform dose

    International Nuclear Information System (INIS)

    Wu Qiuwen; Djajaputra, David; Liu, Helen H.; Dong Lei; Mohan, Radhe; Wu, Yan

    2005-01-01

    With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this study was to investigate the effectiveness of gEUD optimization to fine tune the dose distributions of IMRT plans. We analyzed the effect of gEUD-based optimization parameters on plan quality. The objective was to determine whether dose distribution to selected structures could be improved using gEUD optimization without adversely altering the doses delivered to other structures, as in sculpting. We hypothesized that by carefully defining gEUD parameters (EUD 0 and n) based on the current dose distributions, the optimization system could be instructed to search for alternative solutions in the neighborhood, and we could maintain the dose distributions for structures already satisfactory and improve dose for structures that need enhancement. We started with an already acceptable IMRT plan optimized with any objective function. The dose distribution was analyzed first. For structures that dose should not be changed, a higher value of n was used and EUD 0 was set slightly higher/lower than the EUD value at the current dose distribution for critical structures/targets. For structures that needed improvement in dose, a higher to medium value of n was used, and EUD 0 was set to the EUD value or slightly lower/higher for the critical structure/target at the current dose distribution. We evaluated this method in one clinical case each of head and neck, lung and prostate cancer. Dose volume histograms, isodose distributions, and relevant tolerance doses for critical structures were used for the assessment. We found that by adjusting gEUD optimization parameters, the dose distribution could be improved with only a few iterations. A larger value of n could lead to

  5. Estimate of dose in crystalline and thyroid in exam complete periapical

    International Nuclear Information System (INIS)

    Bonzoumet, S.P.J.; Braz, D.; Barroso, R.C.; Mauricio, C.L.P.; Domingues, C.; Padilha, L.G.F.

    2006-01-01

    The constant achievement of dental radiography portrays the necessity of care in this practice for neither patient nor professional subject to a risk of excessive radiation. The main aim of this work is to estimate the crystalline and thyroid absorbed dose, during dental radiography. To evaluate the dose distribution it was used thermoluminescent dosimeter T.L.D.100. The measures were carried out on patients during intra-oral dental radiography in some dental clinics in Rio de Janeiro. Three dental equipments were investigated: Dhabi ATLANTE 1070, DABI ATLANTE 70x and SELETRONIC 70x. Analyzing the doses evaluated, it can be observed that there is a variation in the obtained values for the three points studied and for the three equipments utilized. It was noticed that while using the DABI1070, a larger dose was taken because of the size field diameter to equipment. In the 70x equipment was that one what obtains best results in every points. The results obtained from the SELETRONIC 70x have shown that there is a difference in two techniques used: with the positioner or without it. This achieved values superior than that, because the tip of patient was on display straight to radiation. This study was useful to confirm the excessive dose, besides of not was biased to nothing for the radiography quality,represents a risk for the patient who retains unnecessary and harmful radiation to system. (authors)

  6. Estimate of dose in crystalline and thyroid in exam complete periapical

    Energy Technology Data Exchange (ETDEWEB)

    Bonzoumet, S.P.J.; Braz, D. [Lab. de Instrumentacao Nuclear, COPPE/UFRJ, CEP, Rio de Janeiro (Brazil); Barroso, R.C. [Rio de Janeiro Univ. do Estado, Instituto de Fisica (Brazil); Mauricio, C.L.P.; Domingues, C. [Instituto de Radioprotecao e Dosimetria IRD / CNEN (Brazil); Padilha, L.G.F. [Rio de Janeiro Univ. Federal, Hospital Universitario (Brazil)

    2006-07-01

    The constant achievement of dental radiography portrays the necessity of care in this practice for neither patient nor professional subject to a risk of excessive radiation. The main aim of this work is to estimate the crystalline and thyroid absorbed dose, during dental radiography. To evaluate the dose distribution it was used thermoluminescent dosimeter T.L.D.100. The measures were carried out on patients during intra-oral dental radiography in some dental clinics in Rio de Janeiro. Three dental equipments were investigated: Dhabi ATLANTE 1070, DABI ATLANTE 70x and SELETRONIC 70x. Analyzing the doses evaluated, it can be observed that there is a variation in the obtained values for the three points studied and for the three equipments utilized. It was noticed that while using the DABI1070, a larger dose was taken because of the size field diameter to equipment. In the 70x equipment was that one what obtains best results in every points. The results obtained from the SELETRONIC 70x have shown that there is a difference in two techniques used: with the positioner or without it. This achieved values superior than that, because the tip of patient was on display straight to radiation. This study was useful to confirm the excessive dose, besides of not was biased to nothing for the radiography quality,represents a risk for the patient who retains unnecessary and harmful radiation to system. (authors)

  7. Work management practices that reduce dose and improve efficiency

    International Nuclear Information System (INIS)

    Miller, D.W.; Hulin, M.

    1998-01-01

    Work management practices at nuclear power plants can dramatically affect the outcome of annual site dose goals and outage costs. This presentation discusses global work management practices that contribute to dose reduction including work philosophy, work selection, work planning, work scheduling, worker training, work implementation and worker feedback. The presentation is based on a two-year international effort (sponsored by NEA/IAEA ISOE) to study effective work practices that reduce dose. Experts in this area believe that effective work selection and planning practices can substantially reduce occupational dose during refueling outages. For example, some plants represented in the expert group complete refueling outages in 12-18 days (Finland) with doses below 0,90 person-Sv. Other plants typically have 50-75 day outages with substantially higher site doses. The fundamental reasons for longer outages and higher occupational doses are examined. Good work management principles that have a proven track record of reducing occupational dose are summarized. Practical methods to reduce work duration and dose are explained. For example, scheduling at nuclear power plants can be improved by not only sequencing jobs on a time line but also including zone and resource-based considerations to avoid zone congestion and manpower delays. An ongoing, global, benchmarking effort is described which provides current duration and dose information for repetitive jobs to participating utilities world-wide. (author)

  8. Changes in higher mental functions in persons with late sequels of exposure to small ionizing radiation doses

    International Nuclear Information System (INIS)

    Turuspekova, S.

    2002-01-01

    This is a report on the results of studies on the state of higher mental function in individuals with a previous history of exposure to small doses ionizing radiations. The disorders observed are assigned under several groups as follows: dyspraxia, gnostic, visual-spatial agnosia, mnestic, mental processes impairment, neurodynamic. Mnestic and acoustic-gnostical disturbances, and those of the mental processes are rather markedly expressed. Mnestic derangements play a major role in the general pattern of cognitive disorders, being characterized by both modal-specific, and modal-nonspecific features. The topical principle of the classification proposed enables to distinguish the syndrome of middle nonspecific brain structures involvement and the cortical syndromes among the higher mental function disorders, invariably encountered in combination and not isolated. The aforementioned points to the diffuse nature of the neuropsychological disorders, with involvement in the process of both nonspecific and specific structures, characterized by predomination of the frontal and temporal brain cortex sections. Impairment of the higher mental functions in young persons of active age with a past history of exposure to small doses ionizing radiations, necessitate to work out effective measures precluding occurrence and intensification of the cognitive defect. (author)

  9. Is It All about the Higher Dose? Why Psychoanalytic Therapy Is an Effective Treatment for Major Depression.

    Science.gov (United States)

    Zimmermann, Johannes; Löffler-Stastka, Henriette; Huber, Dorothea; Klug, Günther; Alhabbo, Sarah; Bock, Astrid; Benecke, Cord

    2015-01-01

    Empirical evidence for the effectiveness of long-term psychodynamic psychotherapy (LTPP) in patients with mood disorders is growing. However, it is unclear whether the effectiveness of LTPP is due to distinctive features of psychodynamic/psychoanalytic techniques or to a higher number of sessions. We tested these rival hypotheses in a quasi-experimental study comparing psychoanalytic therapy (i.e., high-dose LTPP) with psychodynamic therapy (i.e., low-dose LTPP) and cognitive-behavioural therapy (CBT) for depression. Analyses were based on a subsample of 77 subjects, with 27 receiving psychoanalytic therapy, 26 receiving psychodynamic therapy and 24 receiving CBT. Depressive symptoms, interpersonal problems and introject affiliation were assessed prior to treatment, after treatment and at the 1-, 2- and 3-year follow-ups. Psychoanalytic techniques were assessed from three audiotaped middle sessions per treatment using the Psychotherapy Process Q-Set. Subjects receiving psychoanalytic therapy reported having fewer interpersonal problems, treated themselves in a more affiliative way directly after treatment and tended to improve in depressive symptoms and interpersonal problems during follow-up as compared with patients receiving psychodynamic therapy and/or CBT. Multilevel mediation analyses suggested that post-treatment differences in interpersonal problems and introject affiliation were mediated by the higher number of sessions, and follow-up differences in depressive symptoms were mediated by the more pronounced application of psychoanalytic techniques. We also found some evidence for indirect treatment effects via psychoanalytic techniques on changes in introject affiliation during follow-up. These results provide support for the prediction that both a high dose and the application of psychoanalytic techniques facilitate therapeutic change in patients with major depression. Psychoanalytic therapy is an effective treatment for major depression, especially in the

  10. The influence of radiation of different doses on biometrical indicators of cucumber

    International Nuclear Information System (INIS)

    Gasanov, S.P.; Guseynova, M.Z.; Gulieva, L.M.; Alieva, M.I.; Eminova, N.M.

    2013-01-01

    As it is known, pre-irradiation of plant seeds is usually applied to improve the productivity of crops. Irradiation of seeds at low doses usually does not cause adverse effects. However, irradiation of seeds with higher doses leads to complete loss of cell division ability. In many cases, the morphological change of the primary leaves, and the observed inhibition of the development to such an extent that the plants are deprived of fruiting abilities. The obtained data shows that with increasing of irradiation dose these parameters decrease, at high radiation doses clearly inhibits development of the fruit

  11. Safety and Immunogenicity of Full-Dose Trivalent Inactivated Influenza Vaccine (TIV) Compared With Half-Dose TIV Administered to Children 6 Through 35 Months of Age.

    Science.gov (United States)

    Halasa, Natasha B; Gerber, Michael A; Berry, Andrea A; Anderson, Edwin L; Winokur, Patricia; Keyserling, Harry; Eckard, Allison Ross; Hill, Heather; Wolff, Mark C; McNeal, Monica M; Edwards, Kathryn M; Bernstein, David I

    2015-09-01

    Children 6 through 35 months of age are recommended to receive half the dose of influenza vaccine compared with older children and adults. This was a 6-site, randomized 2:1, double-blind study comparing full-dose (0.5 mL) trivalent inactivated influenza vaccine (TIV) with half-dose (0.25 mL) TIV in children 6 through 35 months of age. Children previously immunized with influenza vaccine (primed cohort) received 1 dose, and those with no previous influenza immunizations (naive cohort) received 2 doses of TIV. Local and systemic adverse events were recorded. Sera were collected before immunization and 1 month after last dose of TIV. Hemagglutination inhibition antibody testing was performed. Of the 243 subjects enrolled (32 primed, 211 naive), data for 232 were available for complete analysis. No significant differences in local or systemic reactions were observed. Few significant differences in immunogenicity to the 3 vaccine antigens were noted. The immune response to H1N1 was significantly higher in the full-dose group among primed subjects. In the naive cohort, the geometric mean titer for all 3 antigens after 2 doses of TIV were significantly higher in the 12 through 35 months compared with the 6 through 11 months age group. Our study confirms the safety of full-dose TIV given to children 6 through 35 months of age. An increase in antibody responses after full- versus half-dose TIV was not observed, except for H1N1 in the primed group. Larger studies are needed to clarify the potential for improved immunogenicity with higher vaccine doses. Recommending the same dose could simplify the production, storage, and administration of influenza vaccines.

  12. Pharmacokinetics and tolerability of a higher rifampin dose versus the standard dose in pulmonary tuberculosis patients.

    NARCIS (Netherlands)

    Ruslami, R.; Nijland, H.M.J.; Alisjahbana, B.; Parwati, I.; Crevel, R. van; Aarnoutse, R.E.

    2007-01-01

    Rifampin is a key drug for tuberculosis (TB) treatment. The available data suggest that the currently applied 10-mg/kg of body weight dose of rifampin may be too low and that increasing the dose may shorten the treatment duration. A double-blind randomized phase II clinical trial was performed to

  13. Population doses from terrestrial gamma exposure in China

    International Nuclear Information System (INIS)

    Ren, T.; Wang, Z.; Zhu, C.

    1992-01-01

    In order to estimate terrestrial gamma radiation exposure three nationwide surveys have been completed since 1981. The population-weighted outdoor and indoor arithmetic means of gamma dose rate based on momentary dose rate measurements using a NaI(Tl) environmental radiation meter and high-pressure ionisation chamber are, respectively, 80.3 nGy.h -1 and 120 nGy.h -1 . Based on integrating dose measurement using TLD CaSO 4 /Dy they are 67 nGy.h -1 and 89 nGy.h -1 respectively, and based on natural radionuclides concentrations in soil, determined by gamma spectroscopy analyses, they are 72.8 nGy.h -1 and 102 nGy.h -1 , respectively. These surveys were conducted independently by different groups. The best estimations of population-weighted gamma dose rates in China, based on all these surveys, would be 70 nGy.h -1 and 98 nGy.h -1 for outdoors and indoors, respectively. The annual average of effective dose equivalent is 0.56 mSv. These values are higher than the world averages estimated by UNSCEAR. The main reason is that the concentrations of 232 Th and 40 K in the soil of China are much higher than the world average estimated. (author)

  14. Technique-dependent decrease in thyroid absorbed dose for dental radiography

    International Nuclear Information System (INIS)

    Wood, R.E.; Bristow, R.G.; Clark, G.M.; Nussbaum, C.; Taylor, K.W.

    1989-01-01

    A LiF thermoluminescent dosimetry (TLD) system, calibrated in the tissue of interest with the beam used for experimentation, was employed to investigate dosages (muGy) to the thyroid region of an anthropomorphic phantom resultant from two dental complete-mouth radiographic procedures. Both techniques were compared in terms of dosages associated with combinations of lead apron and thyroid collar shielding while using a 70-kVp or 90-kVp x-ray beam for a 20-film complete-mouth series. Lead shielding significantly decreased the dose to the thyroid using both techniques (p less than 0.05). The use of the 90-kVp beam resulted in a significant reduction in the thyroid absorbed dose when using the bisecting angle technique (p less than 0.05) but caused a significant increase in the thyroid absorbed dose when the paralleling technique was used (p less than 0.05). The implementation of higher kilovoltage techniques in dental offices must therefore be dependent on the radiographic technique employed

  15. Poster - 56: Preliminary comparison of FF- and FFF-VMAT for prostate plans with higher rectal dose

    International Nuclear Information System (INIS)

    Liu, Baochang; Darko, Johnson; Osei, Ernest

    2016-01-01

    Purpose: A recent retrospective study found 53 patients previously treated to 78Gy/39 using flattened filtered (FF) 6X-VMAT at GRRCC had rectal DVH more than one standard deviation higher than the average. This study was to investigate if using 6FFFor10FFF beams could reduce these DVHs without compromising target coverage. Methods: Twenty patients’ plans were re-planed with 2-arc 6X-VMAT, 6FFF-VMAT and 10FFF-VMAT using the Eclipse TPS following departmental protocol. All plans had the same optimization and normalization, and were evaluated against the acceptance criteria from the QUANTEC and Emami. Statistical differences in the mean dose to OARs (D m ) and PTV homogeneity index (HI) between energies were tested using the paired sample Wilcoxon signed rank statistical method (p<0.05). Beam delivery accuracy was checked on five patients using portal dosimetry (PD). Results: The PTV HI for the 10FFF shows no statistical difference from the 6X. All the OARs, except left femoral head with 6FFF, have significantly lower Dm using 6FFF and 10FFF .There is no difference in the maximum doses to rectum and bladder and are limited by the prescribed doses. Measurements show good agreements in the gamma evaluation (3%/3mm) for all energies. Conclusion: This preliminary study shows that doses to the OARs are reduced using 10FFF for the same target coverage. The plans using 6FFF result in lower doses to some OARs, and statistically different PTV HI. All plans showed very good agreement with measurements.

  16. Poster - 56: Preliminary comparison of FF- and FFF-VMAT for prostate plans with higher rectal dose

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Baochang; Darko, Johnson; Osei, Ernest [Grand River Regional Cancer Centre, Kitchener, Ontario (Canada)

    2016-08-15

    Purpose: A recent retrospective study found 53 patients previously treated to 78Gy/39 using flattened filtered (FF) 6X-VMAT at GRRCC had rectal DVH more than one standard deviation higher than the average. This study was to investigate if using 6FFFor10FFF beams could reduce these DVHs without compromising target coverage. Methods: Twenty patients’ plans were re-planed with 2-arc 6X-VMAT, 6FFF-VMAT and 10FFF-VMAT using the Eclipse TPS following departmental protocol. All plans had the same optimization and normalization, and were evaluated against the acceptance criteria from the QUANTEC and Emami. Statistical differences in the mean dose to OARs (D{sub m}) and PTV homogeneity index (HI) between energies were tested using the paired sample Wilcoxon signed rank statistical method (p<0.05). Beam delivery accuracy was checked on five patients using portal dosimetry (PD). Results: The PTV HI for the 10FFF shows no statistical difference from the 6X. All the OARs, except left femoral head with 6FFF, have significantly lower Dm using 6FFF and 10FFF .There is no difference in the maximum doses to rectum and bladder and are limited by the prescribed doses. Measurements show good agreements in the gamma evaluation (3%/3mm) for all energies. Conclusion: This preliminary study shows that doses to the OARs are reduced using 10FFF for the same target coverage. The plans using 6FFF result in lower doses to some OARs, and statistically different PTV HI. All plans showed very good agreement with measurements.

  17. On the regularity of mild solutions to complete higher order differential equations on Banach spaces

    Directory of Open Access Journals (Sweden)

    Nezam Iraniparast

    2015-09-01

    Full Text Available For the complete higher order differential equation u(n(t=Σk=0n-1Aku(k(t+f(t, t∈ R (* on a Banach space E, we give a new definition of mild solutions of (*. We then characterize the regular admissibility of a translation invariant subspace al M of BUC(R, E with respect to (* in terms of solvability of the operator equation Σj=0n-1AjXal Dj-Xal Dn = C. As application, almost periodicity of mild solutions of (* is proved.

  18. Population doses from terrestrial gamma exposure in China

    International Nuclear Information System (INIS)

    Ren, T.; Wang, Z.; Zhu, C.

    1993-01-01

    In order to estimate terrestrial gamma radiation exposures, three nationwide surveys have been completed since 1981. The population weighted outdoor and indoor arithmetic means of gamma dose rates based on momentary measurements using a NaI(T1) environmental radiation meter and a high pressured ionization chamber are 80.3 and 120 nGy.h -1 . The means based on integrating measurements using TLD natural radionuclides concentrations in soil, determined by gamma spectrometry analyses, are 72.8 and 102 nGy.h -1 , respectively. These surveys were conducted independently and equally representative. The best estimation of site-averaged and population weighted gamma dose rates in China, based on all these surveys, would be 70 and 98 nGy.h -1 for indoor and outdoor, respectively. The annual average of effective dose equivalent is 0.56 mSv. These values are higher than the world averages estimated by UNSCEAR. The main reason is that the concentrations of 232 Th and 40 K in soil of China are much higher than the world average estimated. (author). 4 refs, 2 tabs

  19. Failure-probability driven dose painting

    International Nuclear Information System (INIS)

    Vogelius, Ivan R.; Håkansson, Katrin; Due, Anne K.; Aznar, Marianne C.; Kristensen, Claus A.; Rasmussen, Jacob; Specht, Lena; Berthelsen, Anne K.; Bentzen, Søren M.

    2013-01-01

    Purpose: To demonstrate a data-driven dose-painting strategy based on the spatial distribution of recurrences in previously treated patients. The result is a quantitative way to define a dose prescription function, optimizing the predicted local control at constant treatment intensity. A dose planning study using the optimized dose prescription in 20 patients is performed.Methods: Patients treated at our center have five tumor subvolumes from the center of the tumor (PET positive volume) and out delineated. The spatial distribution of 48 failures in patients with complete clinical response after (chemo)radiation is used to derive a model for tumor control probability (TCP). The total TCP is fixed to the clinically observed 70% actuarial TCP at five years. Additionally, the authors match the distribution of failures between the five subvolumes to the observed distribution. The steepness of the dose–response is extracted from the literature and the authors assume 30% and 20% risk of subclinical involvement in the elective volumes. The result is a five-compartment dose response model matching the observed distribution of failures. The model is used to optimize the distribution of dose in individual patients, while keeping the treatment intensity constant and the maximum prescribed dose below 85 Gy.Results: The vast majority of failures occur centrally despite the small volumes of the central regions. Thus, optimizing the dose prescription yields higher doses to the central target volumes and lower doses to the elective volumes. The dose planning study shows that the modified prescription is clinically feasible. The optimized TCP is 89% (range: 82%–91%) as compared to the observed TCP of 70%.Conclusions: The observed distribution of locoregional failures was used to derive an objective, data-driven dose prescription function. The optimized dose is predicted to result in a substantial increase in local control without increasing the predicted risk of toxicity

  20. Utilization of the higher plants in a study on hereditary effect of low-dose irradiation

    International Nuclear Information System (INIS)

    Yamashita, Jun

    1976-01-01

    Some problems in a study of hereditary effect of low-dose irradiation, which used the higher plants (tradescantia, peas, etc.) as materials, were mentioned. Conditions to be used as materials were mentioned as follows: 1) the materials must have high radio-sensitivity, 2) the natural mutation of the materials must be low, 3) hereditary uniformity and stability of genes in the materials were important, and 4) in case of considering the materials as environmental radiation monitors, the observation period must be long and the duration from exposure to detection of mutation must be short. Tradescantia has most of these conditions, but the greatest fault is that the object of its observation is mutation of somatic cells, and hereditary study is impossible. Therefore, it is necessary to find out other materials in order to solve the problem whether there is a difference in relative frequency of chromosomal abnormalities, which occurrs in germinal cells and is transmitted to posterity, between low and high doses or not. (Serizawa, K.)

  1. Professional exposure of medical workers: radiation levels, radiation risk and personal dose monitoring

    International Nuclear Information System (INIS)

    Bai Guang

    2005-01-01

    The application of radiation in the field of medicine is the most active area. Due to the rapid and strong development of intervention radiology at present near 20 years, particularly, the medical workers become a popularize group which most rapid increasing and also receiving the must high of professional exposure dose. Because, inter alias, radiation protection management nag training have not fully follow up, the aware of radioactive protection and appropriate approach have tot fully meet the development and need, the professional exposure dose received by medical workers, especially those being engaged in intervention radiology, are more higher, as well as have not yet fully receiving the complete personal dose monitoring, the medical workers become the population group which should be paid the most attention to. The writer would advice in this paper that all medical workers who being received a professional radiation exposure should pay more attention to the safety and healthy they by is strengthening radiation protection and receiving complete personal dose monitoring. (authors)

  2. Population doses from terrestrial gamma exposure in China

    Energy Technology Data Exchange (ETDEWEB)

    Ren, T.; Wang, Z.; Zhu, C. (Ministry of Public Health, Beijing, BJ (China))

    1992-01-01

    In order to estimate terrestrial gamma radiation exposure three nationwide surveys have been completed since 1981. The population-weighted outdoor and indoor arithmetic means of gamma dose rate based on momentary dose rate measurements using a NaI(Tl) environmental radiation meter and high-pressure ionisation chamber are, respectively, 80.3 nGy.h[sup -1] and 120 nGy.h[sup -1]. Based on integrating dose measurement using TLD CaSO[sub 4]/Dy they are 67 nGy.h[sup -1] and 89 nGy.h[sup -1] respectively, and based on natural radionuclides concentrations in soil, determined by gamma spectroscopy analyses, they are 72.8 nGy.h[sup -1] and 102 nGy.h[sup -1], respectively. These surveys were conducted independently by different groups. The best estimations of population-weighted gamma dose rates in China, based on all these surveys, would be 70 nGy.h[sup -1] and 98 nGy.h[sup -1] for outdoors and indoors, respectively. The annual average of effective dose equivalent is 0.56 mSv. These values are higher than the world averages estimated by UNSCEAR. The main reason is that the concentrations of [sup 232]Th and [sup 40]K in the soil of China are much higher than the world average estimated. (author).

  3. High dose Intravenous Anti-D Immune Globulin is More Effective and Safe in Indian Paediatric Patients of Immune Thrombocytopenic Purpura.

    Science.gov (United States)

    Swain, Trupti Rekha; Jena, Rabindra Kumar; Swain, Kali Prasanna

    2016-12-01

    Immune Thrombocytopenia (ITP) is characterised by an autoimmune antibody-mediated destruction of platelets and impaired platelet production. Few controlled trials exist to guide management of patients with ITP in Indian scenario for which patients require an individualized approach. Anti-D (Rho (D) immune globulin) at a higher dose can prove to be a cost effective and safe alternative for Indian patients with ITP. To compare the safety and efficacy of higher dose (75μg/kg) intravenous Anti-D immune globulin against the standard dose of 50μg/kg for the management of ITP in Indian patients. One hundred and sixty four children with newly diagnosed ITP between 4-14 years were randomly selected for inclusion and were treated with 50μg/kg (standard dose) or 75μg /kg (higher dose) of Anti-D to compare the efficacy and safety of higher dose intravenous anti-D immune globulin. Efficacy of Anti-D was measured in terms of rate of response and median time to response for increase in platelet counts. Any adverse event was noted. A decrease in haemoglobin concentration suggested accompanying haemolysis. Seventy one out of 84 patients treated with Anti-D at 75μg/kg produced complete response (85%) with median time of response being 2.5 days. On the contrary, 45 patients (70%) patients treated with 50μg/kg had complete response. However, there was no significant increase in haemolysis with higher dose. A significant correlation was found between dose and peak increase in platelet count measured at 7 th day following administration. However, there was no relationship between the decrease in haemoglobin and the dose given, or between the increase in platelet count and fall in haemoglobin. A 75μg/kg dose of Anti-D is more effective with acceptable side effect in comparison to 50μg dose for treatment of newly diagnosed Indian patients of ITP.

  4. Efficacy and safety of budesonide/formoterol single inhaler therapy versus a higher dose of budesonide in moderate to severe asthma

    NARCIS (Netherlands)

    Scicchitano, R; Aalbers, R; Ukena, D; Manjra, A; Fouquert, L; Centanni, S; Boulet, LP; Naya, IP; Hultquist, C

    Objectives:This study evaluated the efficacy and safety of a novel asthma management strategy - budesonide/formoterol for both maintenance and symptom relief (Symbicort Single Inhaler Therapy*) - compared with a higher maintenance dose of budesonide in patients with moderate to severe asthma.

  5. Dose finding study of granisetron in patients receiving high-dose cisplatin chemotherapy. The Granisetron Study Group.

    Science.gov (United States)

    Riviere, A.

    1994-01-01

    The efficacy and safety of three different doses of granisetron (2 micrograms kg-1, group A; 10 micrograms kg-1, group B; 40 micrograms kg-1, group C) were compared in a randomised, double-blind study of 157 patients due to receive high-dose cisplatin therapy (mean dose > 97 mg m-2). In each group, up to two 3 mg rescue doses of granisetron were allowed if more than mild nausea or vomiting occurred. In group A 30.8%, in group B 61.5% and in group C 67.9% of patients were complete responders (i.e. no vomiting or nothing worse than mild nausea) during the first 24 h. These differences are significant between groups A and B, and A and C. There were no statistically significant differences in any efficacy variable between the 10 micrograms kg-1 and 40 micrograms kg-1 groups, although in each case the trend favoured the higher dose. Additional rescue doses resulted in resolved or improved symptoms in 95.3% for the first rescue dose and 93.3% for the second. Over the 7 days of the study, 82.7%, 82.7% and 86.8% of patients in groups A, B and C respectively were treated with granisetron alone. Headache was the most common side-effect, reported by 9.6% of patients; the majority of headaches were mild. There was no difference between the treatment groups regarding the adverse event rate. We concluded that prophylactic doses of 10 or 40 micrograms kg-1 lead to a safe and satisfactory degree of control of nausea and vomiting induced by high-dose cisplatin. PMID:8180032

  6. Dose rate effectiveness in radiation-induced teratogenesis in mice

    International Nuclear Information System (INIS)

    Kato, F.; Ootsuyama, A.; Norimura, T.

    2000-01-01

    To investigate the role of p53 gene in tissue repair of teratogenic injury, we compared incidence of radiation-induced malformations in homozygous p53(-/-) mice, heterozygous p53(+/-) mice and wild-type p53(+/+) mice. After X-irradiation with 2 Gy at high dose rate on 9.5 days of gestation, p53(-/-) mice showed higher incidences of anomalies and higher resistance to prenatal deaths than p53(+/+) mice. This reciprocal relationship of radiosensitivity to anomalies and deaths supports the notion that embryos or fetuses have a p53-dependent 'guardian' that aborts cells bearing radiation-induced teratogenic DNA damage. In fact, after X-irradiation, the number of apoptotic cells was greatly increased in p53(+/+) fetuses but not in p53(-/-) fetuses. The same dose of γ-ray exposure at low dose rate on 9.5-10.5 day of gestation produced significant reduction of radiation-induced malformation in p53(+/+) and p53(+/-) mice, remained teratogenic for p53(-/-) mice. These results suggest that complete elimination of teratogenic damage from irradiated tissues requires the concerted cooperation of two mechanisms; proficient DNA repair and the p53-dependent apoptotic tissue repair. When concerted DNA repair and apoptosis functions efficiently, there is a threshold dose-rate for radiation-induced malformations. (author)

  7. The effect of dose, dose rate, route of administration, and species on tissue and blood levels of benzene metabolites

    International Nuclear Information System (INIS)

    Henderson, R.F.; Sabourin, P.J.; Bechtold, W.E.; Griffith, W.C.; Medinsky, M.A.; Birnbaum, L.S.; Lucier, G.W.

    1989-01-01

    Studies were completed in F344/N rats and B6C3F 1 mice to determine the effect of dose, dose rate, route of administration, and rodent species on formation of total and individual benzene metabolites. Oral doses of 50 mg/kg or higher saturated the capacity for benzene metabolism in both rats and mice, resulting in an increased proportion of the administered dose being exhaled as benzene. The saturating air concentration for benzene metabolism during 6-hr exposures was between 130 and 900 ppm. At the highest exposure concentration, rats exhaled approximately half of the internal dose retained at the end of the 6-hr exposure as benzene; mice exhaled only 15% as benzene. Mice were able to convert more of the inhaled benzene to metabolites than were rats. In addition, mice metabolized more of the benzene by pathways leading to the putative toxic metabolites, benzoquinone and muconaldehyde, than did rats. In both rats and mice, the effect of increasing dose, administered orally or by inhalation, was to increase the proportion of the total metabolites that were the products of detoxification pathways relative to the products of pathways leading to putative toxic metabolites. This indicates low-affinity, high-capacity pathways for detoxification and high-affinity, low-capacity pathways leading to putative toxic metabolites. If the results of rodent studied performed at high doses were used to assess the health risk at low-dose exposures to benzene, the toxicity of benzene would be underestimated

  8. Awareness and Practice of Complete Hepatitis B Vaccination and Anti-HBs Testing in Vaccinated Health Care Workers

    Directory of Open Access Journals (Sweden)

    Annapurna G. Sajjan

    2015-04-01

    Full Text Available Background: Hepatitis B is a serious and common infectious disease affecting millions of people worldwide. Health Care Workers (HCW are at an increased risk of occupational exposure to HBV and the incidence is 2-4 times higher than in the general population. Despite potential risks, awareness and vaccine compliance is poor among the HCWs. Aim: To assess the awareness of complete Hepatitis B vaccination, anti-HBs testing & protective titres and determine the anti HBs titres amongst vaccinated HCWs. Material & Methods: A total of 500 Health care workers of both sexes in the age group from 20- 60 years vaccinated against Hepatitis B were tested for anti-HBs titres by quantitative ELISA. Results: The rate of complete immunization was 81.4% in doctors, 63.3% in nursing staff and 90% in the technical staff. Amongst the 500 participants, 70.8% had received all the doses and 29.2% incomplete doses of the vaccine. Titres of ≥ 10 mIU/ml were demonstrated in 84.4% of HCWs who received all the doses and in 65.7% those who defaulted. Conclusions: The results of the study indicate lack of awareness about complete HB vaccination and the importance of post vaccination testing in HCWs.

  9. Effective dose comparison between stitched and single FOV in CBCT protocols for complete dental arcade

    International Nuclear Information System (INIS)

    Soares, Maria Rosangela; Batista, Wilson Otto; Antonio, Patricia Lara de; Caldas, Linda V.E.; Maia, Ana F.

    2015-01-01

    Objective: The objective of this study was to assess and compare protocols with a single field of view and multiple stitched field of view with a similar clinical purpose by means of effective dose value. Materials and methods: Measurements of absorbed dose were performed with thermoluminescent dosemeters inserted in the position of organs/tissues of a female anthropomorphic phantom and from these values the effective dose was calculated, utilizing weighting factor tissue-ICRP 103 (2007). Results: The results obtained in this study for effective dose are within the range of 43.1 µSv and 111.5 µSv for equipment using protocols with single FOV and in the range of 44.5 µSv and 236.2 µSv for equipments that using protocols with stitched field of view. Conclusions: In terms of the value of effective dose, stitched FOV protocols do not have any advantage over the single field of view protocols. This results suggest the necessity for knowledge of the exposure parameters and effective dose values associated with each image protocol. - Highlights: • The study relies on the comparison of two protocols with similar goals of CBCT: stitched protocols and single protocols. • The stitched FOV protocol is more specific and it is good option when want imaging only of some dental units. • In relation the effective dose, single FOV protocols presents advantage over the stitched FOV protocols. • Know the exposure parameters and effective dose values associated with each image protocol is necessity for request the best CBCT tomographic image

  10. External beam radiotherapy boosted with high dose rate brachytherapy in completely resected uterine sarcomas. Is this a treatment option?

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, Antonio Cassio Assis; Novaes, Paulo Eduardo Ribeiro dos Santos; Maia, Maria Aparecida Conte; Ferrigno, Robson; Fogarolli, Ricardo; Salvajoli, Joao Vitor [Hospital de Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Oncologia de Radiacao]. E-mail: pellizzon@aol.com

    2005-04-15

    Uterine sarcoma (US) is a relative rare tumor, which accounts for only about 3-5% of all uterine cancers. Aggressive cytoreductive surgery at the time of the initial diagnosis with maximum tumor debulking may lead to a prolonged survival or cure. Objective: to identify and review the role of adjuvant external beam radiation therapy (EBRT) associated with high dose rate brachytherapy (HDRB) in the management of patients presenting US with complete resection. Material and methods: this study is a retrospective analysis of 23 patients with US treated from 10/92 to 03/03, with surgery, external beam radiation therapy (EBRT) and high dose rate brachytherapy (HDRB). The inclusion criteria for study participation included: histologically proven and graded US, completely resection of tumor, Karnofsky status 60-100, absence of significant infection, and recovery from recent surgery. Results: The median age of patients was 62 years (range 39-84); ten-year actuarial disease-free and overall survivals were 42.2% and 63.4%, respectively. On univariate analysis, predictive factors for disease-free survival (DFS) were age at initial presentation (p=0.0268), parity (p=0.0441), tumor grade (p= 0.0095), cervical or vaginal invasion (p=0.0014) and node dissection at time of surgery (p= 0.0471). On multivariate analysis, the only predictive factor was cervical or vaginal invasion (p= 0.048), hazard ratio of 4.7. Conclusion: it is quite likely that neither radiotherapy nor chemotherapy alone will appreciably improve survival in US. If radiation therapy provides better locoregional tumor control, hematogenous metastases will assume an even greater proportion of treatment failures. Unfortunately, our small and heterogeneous group analyzed precludes any definitive conclusions about the impact of HDRB associated to EBRT radiation therapy on recurrence or survival. (author)

  11. External beam radiotherapy boosted with high dose rate brachytherapy in completely resected uterine sarcomas. Is this a treatment option?

    International Nuclear Information System (INIS)

    Pellizzon, Antonio Cassio Assis; Novaes, Paulo Eduardo Ribeiro dos Santos; Maia, Maria Aparecida Conte; Ferrigno, Robson; Fogarolli, Ricardo; Salvajoli, Joao Vitor

    2005-01-01

    Uterine sarcoma (US) is a relative rare tumor, which accounts for only about 3-5% of all uterine cancers. Aggressive cytoreductive surgery at the time of the initial diagnosis with maximum tumor debulking may lead to a prolonged survival or cure. Objective: to identify and review the role of adjuvant external beam radiation therapy (EBRT) associated with high dose rate brachytherapy (HDRB) in the management of patients presenting US with complete resection. Material and methods: this study is a retrospective analysis of 23 patients with US treated from 10/92 to 03/03, with surgery, external beam radiation therapy (EBRT) and high dose rate brachytherapy (HDRB). The inclusion criteria for study participation included: histologically proven and graded US, completely resection of tumor, Karnofsky status 60-100, absence of significant infection, and recovery from recent surgery. Results: The median age of patients was 62 years (range 39-84); ten-year actuarial disease-free and overall survivals were 42.2% and 63.4%, respectively. On univariate analysis, predictive factors for disease-free survival (DFS) were age at initial presentation (p=0.0268), parity (p=0.0441), tumor grade (p= 0.0095), cervical or vaginal invasion (p=0.0014) and node dissection at time of surgery (p= 0.0471). On multivariate analysis, the only predictive factor was cervical or vaginal invasion (p= 0.048), hazard ratio of 4.7. Conclusion: it is quite likely that neither radiotherapy nor chemotherapy alone will appreciably improve survival in US. If radiation therapy provides better locoregional tumor control, hematogenous metastases will assume an even greater proportion of treatment failures. Unfortunately, our small and heterogeneous group analyzed precludes any definitive conclusions about the impact of HDRB associated to EBRT radiation therapy on recurrence or survival. (author)

  12. Sinus histiocytosis with massive lymphadenopathy Rosai-Dorfman's disease as cause of isolated hilar lymphadenopathy and complete remission after high dose steroid

    International Nuclear Information System (INIS)

    Al-Jahdali, Hamdan H.; Al-Shirawi, Nehad N.; Bamefleh, Hana S.; Yamani, Nizar M.

    2008-01-01

    Rosai-Dorfman's Disease, also known as sinus histiocytosis with massive lymphadenopathy SHML, is a rare histiocytic proliferative disorder and a distinct clinic-pathological feature of unknown origin. Painless cervical lymphadenopathy is the most common clinical presentation. Different treatment modalities have been tried with variable responses, however, there is no consensus on the best modality of treatment. Here, we present a case report of SHML causing isolated hilar lymphadenopathy with complete remission for more than 6 years, after a short course of high dose steroid dexamethasone 20 mg daily for 3 days. (author)

  13. Hepatitis A, B, and A/B vaccination series completion among US adults: a claims-based analysis.

    Science.gov (United States)

    Ghaswalla, Parinaz K; Patterson, Brandon J; Cheng, Wendy Y; Duchesneau, Emilie; Macheca, Monica; Duh, Mei Sheng

    2018-06-20

    Hepatitis A and B disease burden persists in the US. We assessed hepatitis A and hepatitis B vaccination series completion rates among 350,240 commercial/Medicare and 12,599 Medicaid enrollees aged ≥19 years. A vaccination series was considered as completed provided that the minimum interval between doses, as defined by the CDC, and the minimum number of doses were reached. We stratified completion rates by vaccine type (i.e. monovalent or bivalent) at initial vaccination for each cohort. In the commercial/Medicare cohort, the series completion rate was 32.0% for hepatitis A and 39.6% for hepatitis B among those who initiated with a monovalent vaccine, and it was 36.2% for hepatitis A and 48.9% for hepatitis B among those who initiated with a bivalent vaccine. In the Medicaid cohort, the series completion rate was 21.0% for hepatitis A and 24.0% for hepatitis B among those who initiated with a monovalent vaccine, and it was 19.0% for hepatitis A and 24.6% for hepatitis B among those who initiated with a bivalent vaccine. In conclusion, hepatitis A and B vaccination series completion rates were low, and appeared to be lower among Medicaid than among commercial/Medicare enrollees. Commercial/Medicare enrollees who initiated with a bivalent vaccine had higher series completion rates than those who initiated with monovalent vaccines - an observation that was not made among Medicaid enrollees.

  14. Dose-to-medium vs. dose-to-water: Dosimetric evaluation of dose reporting modes in Acuros XB for prostate, lung and breast cancer

    Directory of Open Access Journals (Sweden)

    Suresh Rana

    2014-12-01

    Full Text Available Purpose: Acuros XB (AXB dose calculation algorithm is available for external beam photon dose calculations in Eclipse treatment planning system (TPS. The AXB can report the absorbed dose in two modes: dose-to-water (Dw and dose-to-medium (Dm. The main purpose of this study was to compare the dosimetric results of the AXB_Dm with that of AXB_Dw on real patient treatment plans. Methods: Four groups of patients (prostate cancer, stereotactic body radiation therapy (SBRT lung cancer, left breast cancer, and right breast cancer were selected for this study, and each group consisted of 5 cases. The treatment plans of all cases were generated in the Eclipse TPS. For each case, treatment plans were computed using AXB_Dw and AXB_Dm for identical beam arrangements. Dosimetric evaluation was done by comparing various dosimetric parameters in the AXB_Dw plans with that of AXB_Dm plans for the corresponding patient case. Results: For the prostate cancer, the mean planning target volume (PTV dose in the AXB_Dw plans was higher by up to 1.0%, but the mean PTV dose was within ±0.3% for the SBRT lung cancer. The analysis of organs at risk (OAR results in the prostate cancer showed that AXB_Dw plans consistently produced higher values for the bladder and femoral heads but not for the rectum. In the case of SBRT lung cancer, a clear trend was seen for the heart mean dose and spinal cord maximum dose, with AXB_Dw plans producing higher values than the AXB_Dm plans. However, the difference in the lung doses between the AXB_Dm and AXB_Dw plans did not always produce a clear trend, with difference ranged from -1.4% to 2.9%. For both the left and right breast cancer, the AXB_Dm plans produced higher maximum dose to the PTV for all cases. The evaluation of the maximum dose to the skin showed higher values in the AXB_Dm plans for all 5 left breast cancer cases, whereas only 2 cases had higher maximum dose to the skin in the AXB_Dm plans for the right breast cancer

  15. Primary experiment aimed at selecting the suitable dose to mutation induction in vicia faba major

    International Nuclear Information System (INIS)

    Nabulsi, Imad; Mir Ali, Nizar

    1992-08-01

    Seeds of a local faba been variety (Mahali) (Vicia faba major) were irradiated with (0, 5, 10, 15, 20, 40, 60, 80, and 100 Gy) of gamma rays and sown under greenhouse and field conditions in Deir Al-Hajar Research Station near Damascus. Four replicates were used in a randomized complete block design. Germination percentage, seedling height, and daily growth rate, were estimated one month and two months after planting for the greenhouse and field treatments respectively. The results showed a stimulation effect in the 5 Gy dose, whereas, the higher doses showed a gradual decrease in seedling height. Doses up to 20 Gy had a similar germination percentage to that of the control (about 75%) whereas, the germination percentage decreased sharply at the higher doses (3% and 0.2% for the 100 Gy under greenhouse and the field respectively). The doses between 20 and 40 Gy were considered optimal for mutation from the plant breeder point of view where the lethality was moderate and an acceptable rate of mutation was shown. (author). 6 refs., 3 tabs., 1 fig

  16. A METHOD TO IMPROVE DOSE ASSESSMENT BY RECONSTRUCTION OF THE COMPLETE ISOTOPES INVENTORY.

    Science.gov (United States)

    Bonin, Alice; Tsilanizara, Aimé

    2017-06-01

    Radiation shielding assessments may underestimate the expected dose if some isotopes at trace level are not considered in the isotopes inventory of the shielded radioactive materials. Indeed, information about traces is not often available. Nevertheless, the activation of some minor isotopic traces may significantly contribute to the dose build-up. This paper presents a new method (Isotopes Inventory Reconstruction-IIR) estimating the concentration of the minor isotopes in the irradiated material at the beginning of the cooling period. The method requires the solution of the inverse problem describing the irradiated material's decay. In a mixture of an irradiated uranium-plutonium oxide shielded by a set-up made of stainless-steel, porous polyethylene plaster and lead methyl methacrylate, the comparison between different methods proves that the IIR-method allows better assessment of the dose than other approximate methods. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Comparison of fluorouracil with additional levamisole, higher-dose folinic acid, or both, as adjuvant chemotherapy for colorectal cancer: a randomised trial. QUASAR Collaborative Group.

    Science.gov (United States)

    2000-05-06

    Standard adjuvant chemotherapy for colorectal cancer consists of fluorouracil with folinic acid or levamisole. The large QUASAR randomised trial aimed to investigate (in a two x two design) whether use of a higher dose of folinic acid or addition of levamisole to fluorouracil and folinic acid improved survival. Patients with colorectal cancer, without evident residual disease, were randomly assigned fluorouracil (370 mg/m2) with high-dose (175 mg) or low-dose (25 mg) L-folinic acid and either active or placebo levamisole. The fluorouracil and folinic acid could be given either as six 5-day courses with 4 weeks between the start of the courses or as 30 once-weekly doses. Levamisole (50 mg) or placebo was given three times daily for 3 days repeated every 2 weeks for 12 courses. The primary endpoint was mortality from any cause. Analyses were by intention to treat. Between 1994 and 1997, 4,927 patients were enrolled. 1,776 had recurrences and 1,576 died. Survival was similar with high-dose and low-dose folinic acid (70.1% vs 71.0% at 3 years; p=0-43), as were 3-year recurrence rates (36.0% vs 35.8%; p=0.94). Survival was worse with levamisole than with placebo (69.4% vs 71.5% at 3 years; p=0.06), and there were more recurrences with the active drug (37.0% vs 34.9% at 3 years; p=0.16). The inclusion of levamisole in chemotherapy regimens for colorectal cancer does not delay recurrence or improve survival. Higher-dose folinic acid produced no extra benefit in these regimens over that from low-dose folinic acid. Trials of chemotherapy versus no chemotherapy will show whether these four treatments are equally effective or equally ineffective.

  18. Model-Based Evaluation of Higher Doses of Rifampin Using a Semimechanistic Model Incorporating Autoinduction and Saturation of Hepatic Extraction.

    Science.gov (United States)

    Chirehwa, Maxwell T; Rustomjee, Roxana; Mthiyane, Thuli; Onyebujoh, Philip; Smith, Peter; McIlleron, Helen; Denti, Paolo

    2016-01-01

    Rifampin is a key sterilizing drug in the treatment of tuberculosis (TB). It induces its own metabolism, but neither the onset nor the extent of autoinduction has been adequately described. Currently, the World Health Organization recommends a rifampin dose of 8 to 12 mg/kg of body weight, which is believed to be suboptimal, and higher doses may potentially improve treatment outcomes. However, a nonlinear increase in exposure may be observed because of saturation of hepatic extraction and hence this should be taken into consideration when a dose increase is implemented. Intensive pharmacokinetic (PK) data from 61 HIV-TB-coinfected patients in South Africa were collected at four visits, on days 1, 8, 15, and 29, after initiation of treatment. Data were analyzed by population nonlinear mixed-effects modeling. Rifampin PKs were best described by using a transit compartment absorption and a well-stirred liver model with saturation of hepatic extraction, including a first-pass effect. Autoinduction was characterized by using an exponential-maturation model: hepatic clearance almost doubled from the baseline to steady state, with a half-life of around 4.5 days. The model predicts that increases in the dose of rifampin result in more-than-linear drug exposure increases as measured by the 24-h area under the concentration-time curve. Simulations with doses of up to 35 mg/kg produced results closely in line with those of clinical trials. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  19. Which dose of bevacizumab is more effective for the treatment of aggressive posterior retinopathy of prematurity: lower or higher dose?

    Directory of Open Access Journals (Sweden)

    Seyhan Dikci

    Full Text Available ABSTRACT Purpose: To compare 0.5 mg and 0.625 mg of bevacizumab for treating aggressive posterior retinopathy of prematurity (AP-ROP. Methods: The medical records of patients with AP-ROP who were administered intravitreal bevacizumab (IVB as a primary treatment at a university clinic were evaluated retrospectively. Five eyes of three patients (Group 1 who received 0.625 mg/0.025 ml IVB and 10 eyes of another five patients (Group 2 who received 0.5 mg/0.02 ml IVB were evaluated. Laser photocoagulation was used as additional treatment after relapses. Anatomic results and complications were evaluated in both groups. Results: We evaluated 15 eyes of eight patients (four girls and four boys with a flat demarcation line at posterior zone 2 and plus disease or stage-3 disease in this study. The mean gestational age of the three babies in Group 1 was 26 ± 1 weeks and the mean birth weight was 835.33 ± 48.01 g. The corresponding values were 25.2 ± 1.6 weeks and 724 ± 139.03 g, respectively, for the five babies in Group 2. Retinal vascularization was completed at a mean postmenstrual duration of 53.6 ± 1.5 weeks without additional treatment in the five eyes in Group 1. Laser photocoagulation for relapse was administered to five of the 10 eyes in Group 2. Retinal vascularization was completed at a mean postmenstrual duration of 47.6 ± 1.5 weeks in the remaining five eyes. None of the patients developed complications such as cataract, glaucoma, retinal tear, retinal or vitreous hemorrhage, or retinal detachment. Conclusion: Although lower IVB doses in the treatment of AP-ROP are expected to be safer in terms of local and systemic side effects in premature infants, these patients may require additional treatment with IVB or laser photocoagulation.

  20. MONTEC, an interactive fortran program to simulate radiation dose and dose-rate responses of populations

    International Nuclear Information System (INIS)

    Perry, K.A.; Szekely, J.G.

    1983-09-01

    The computer program MONTEC was written to simulate the distribution of responses in a population whose members are exposed to multiple radiation doses at variable dose rates. These doses and dose rates are randomly selected from lognormal distributions. The individual radiation responses are calculated from three equations, which include dose and dose-rate terms. Other response-dose/rate relationships or distributions can be incorporated by the user as the need arises. The purpose of this documentation is to provide a complete operating manual for the program. This version is written in FORTRAN-10 for the DEC system PDP-10

  1. Dose response of PEG 3350 for the treatment of childhood fecal impaction.

    Science.gov (United States)

    Youssef, Nader N; Peters, John M; Henderson, Wendy; Shultz-Peters, Sandra; Lockhart, Danielle K; Di Lorenzo, Carlo

    2002-09-01

    To investigate the efficacy and safety of polyethylene glycol (PEG) 3350 in the treatment of childhood fecal impaction. This was a prospective, double-blind, parallel, randomized study of 4 doses of PEG 3350; 0.25 g/kg per day, 0.5 g/kg per day, 1 g/kg per day, 1.5 g/kg per day, given for 3 days in children with constipation for >3 months and evidence of fecal impaction. Forty patients completed the study (27 boys, median age 7.5, range 3.3-13.1 years). Disimpaction occurred in 75% of children, with a significant difference between the two higher doses and the lower doses (95% vs 55%, P PEG 3350 is safe and effective in the treatment of childhood fecal impaction at doses of 1 and 1.5 g/kg per day.

  2. Preoperative radiation with concurrent chemotherapy for resectable rectal cancer: Effect of dose escalation on pathologic complete response, local recurrence-free survival, disease-free survival, and overall survival

    International Nuclear Information System (INIS)

    Wiltshire, Kirsty L.; Ward, Iain G.; Swallow, Carol; Oza, Amit M.; Cummings, Bernard; Pond, Gregory R.; Catton, Pamela; Kim, John; Ringash, Jolie; Wong, Chong S.; Wong, Rebecca; Siu, Lillian L.; Moore, Malcolm; Brierley, James

    2006-01-01

    Purpose: Three Phase II studies of preoperative radiotherapy and concurrent 5FU chemotherapy were undertaken. The primary endpoints were acute toxicity and pathologic complete response rate (pCR). Secondary endpoints were local recurrence-free survival (LRFS), disease-free survival (DFS), and overall survival (OS). Methods and Materials: A total of 134 patients with adenocarcinoma of the rectum (clinical T3/T4 or N1/N2) were treated. The initial cohort received 40 Gy in 20 fractions, the second 46 Gy in 23 fractions, and the third 50 Gy in 25 fractions. 5FU (225 mg/m 2 /day) was given continuously throughout radiotherapy. A total of 121 patients underwent surgical resection. Results: Treatment was well tolerated. Grade 3/4 acute toxicity was observed in 13%, 4%, and 14% of patients in the 40 Gy, 46 Gy, and 50 Gy cohorts, respectively (p = 0.20). pCR was documented in 15%, 23%, and 33% of patients, respectively (p = 0.07). The 2-year actuarial LRFS was 72%, 90%, and 89% (p = 0.02); DFS was 62%, 84%, and 78% (p = 0.02); and OS was 72%, 94%, and 92%, respectively (p = 0.03). Conclusions: All treatment schedules were well tolerated. There was a trend toward increased pCR with higher doses. A statistically significant increase in LRFS, DFS, and OS was seen with radiation doses of 46 Gy and greater, but there was no difference between 46 Gy and 50 Gy

  3. Quality control of 192Ir high dose rate after loading brachytherapy dose veracity

    International Nuclear Information System (INIS)

    Feng Zhongsu; Xu Xiao; Liu Fen

    2008-01-01

    Recently, 192 Ir high dose rate (HDR) afterloading are widely used in brachytherapy. The advantage of using HDR systems over low dose rate systems are shorter treatment time and higher fraction dose. To guarantee the veracity of the delivery dose, several quality control methods are deseribed in this work. With these we can improve the position precision, time precision and dose precision of the brachytherapy. (authors)

  4. The effect of low-dose neutron irradiation on extracellular matrix

    International Nuclear Information System (INIS)

    Chen Tiehe; Lu Yongjie; Chai Mingsheng; Peng Wulin; Yang Yifang; Pan Yan; Chen Jinguo

    2003-01-01

    Projective: To study the effect of neutron irradiation on extracellular matrix. Methods: 120 male wistar rats were divided into four groups at random, and then exposed to neutron of 252 Cf-source at the doses of 0, 0.29, 0.62 and 1.20 Gy, respectively. After the exposure of 3 days, 1 month and 2 months, the rats were sacrificed and lung tissue specimens stored at -30 degree C. Hyaluronan, laminin, type III procollagen and type IV collagen in the lung tissue were detected by the method of radioimmunoassay. Results: The differences of the levels of hyaluronan in lung tissue among the groups were unsignificant. The levels of laminin in 0.29, 0.62 and 1.20 Gy groups after the 3-day exposure were remarkably different to those of the control group, and unable to recover completely even 2 months after the exposure. The levels of type IV collagen in higher three irradiated groups were all higher, but not significantly. The levels of type III procollagen in the early stage after exposure were higher, and later they lowered. Conclusion: The levels of some components of extracellular matrix in the lung tissue of rat can be changed by low-dose of neutron irradiation, but their variational modes and degrees depend on the dose of neutron irradiation and the length of period after exposure

  5. Health effects of low doses at low dose rates: dose-response relationship modeling in a cohort of workers of the nuclear industry; Effets sanitaires des faibles doses a faibles debits de dose: modelisation de la relation dose-reponse dans une cohorte de travailleurs du nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Metz-Flamant, Camille

    2011-09-19

    The aim of this thesis is to contribute to a better understanding of the health effects of chronic external low doses of ionising radiation. This work is based on the French cohort of CEA-AREVA NC nuclear workers. The mains stages of this thesis were (1) conducting a review of epidemiological studies on nuclear workers, (2) completing the database and performing a descriptive analysis of the cohort, (3) quantifying risk by different statistical methods and (4) modelling the exposure-time-risk relationship. The cohort includes monitored workers employed more than one year between 1950 and 1994 at CEA or AREVA NC companies. Individual annual external exposure, history of work, vital status and causes of death were reconstructed for each worker. Standardized mortality ratios using French national mortality rates as external reference were computed. Exposure-risk analysis was conducted in the cohort using the linear excess relative risk model, based on both Poisson regression and Cox model. Time dependent modifying factors were investigated by adding an interaction term in the model or by using exposure time windows. The cohort includes 36, 769 workers, followed-up until age 60 in average. During the 1968- 2004 period, 5, 443 deaths, 2, 213 cancers, 62 leukemia and 1, 314 cardiovascular diseases were recorded. Among the 57% exposed workers, the mean cumulative dose was 21.5 milli-sieverts (mSv). A strong Healthy Worker Effect is observed in the cohort. Significant elevated risks of pleura cancer and melanoma deaths were observed in the cohort but not associated with dose. No significant association was observed with solid cancers, lung cancer and cardiovascular diseases. A significant dose-response relationship was observed for leukemia excluding chronic lymphatic leukemia, mainly for doses received less than 15 years before and for yearly dose rates higher than 10 mSv. This PhD work contributes to the evaluation of risks associated to chronic external radiation

  6. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Gustafson, Gary; Gonzalez, Jose; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-01-01

    Purpose: To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Methods and Materials: Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level ≥10.0 ng/mL, Gleason score ≥7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. Results: The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p<0.001). Improvement occurred in the cause-specific survival in favor of the brachytherapy high-dose level (p=0.014). On multivariate analysis, a low-dose level, higher Gleason score, and higher nadir value were associated with increased biochemical failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Conclusion: Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause

  7. Hispanic mothers’ beliefs regarding HPV vaccine series completion in their adolescent daughters

    Science.gov (United States)

    Roncancio, A. M.; Ward, K. K.; Carmack, C. C.; Mu�oz, B. T.; Cribbs, F. L.

    2017-01-01

    Abstract Rates of human papillomavirus (HPV) vaccine series completion among adolescent Hispanic females in Texas in 2014 (∼39%) lag behind the Healthy People 2020 goal (80%). This qualitative study identifies Hispanic mothers’ salient behavioral, normative and control beliefs regarding having their adolescent daughters complete the vaccine series. Thirty-two mothers of girls (aged 11–17) that had received at least one dose of the HPV vaccine, completed in-depth interviews. Six girls had received one dose of the HPV vaccine, 10 girls had received two doses, and 16 girls had received all three doses. The questions elicited salient: (i) experiential and instrumental attitudes (behavioral beliefs); (ii) supporters and non-supporters (normative beliefs) and (iii) facilitators and barriers (control beliefs). Directed content analysis was employed to select the most salient beliefs. Mothers: (i) expressed salient positive feelings (e.g. good, secure, happy and satisfied); (ii) believed that completing the series resulted in positive effects (e.g. protection, prevention); (iii) believed that the main supporters were themselves, their daughter’s father and doctor with some of their friends not supporting series completion and (iv) believed that vaccine affordability, information, transportation, ease of scheduling and keeping vaccination appointments and taking their daughter’s immunization card to appointments were facilitators. This study represents the first step in building theory-based framework of vaccine series completion for this population. The beliefs identified provide guidance for health care providers and intervention developers. PMID:28088755

  8. ''Low dose'' and/or ''high dose'' in radiation protection: A need to setting criteria for dose classification

    International Nuclear Information System (INIS)

    Sohrabi, M.

    1997-01-01

    The ''low dose'' and/or ''high dose'' of ionizing radiation are common terms widely used in radiation applications, radiation protection and radiobiology, and natural radiation environment. Reading the title, the papers of this interesting and highly important conference and the related literature, one can simply raise the question; ''What are the levels and/or criteria for defining a low dose or a high dose of ionizing radiation?''. This is due to the fact that the criteria for these terms and for dose levels between these two extreme quantities have not yet been set, so that the terms relatively lower doses or higher doses are usually applied. Therefore, setting criteria for classification of radiation doses in the above mentioned areas seems a vital need. The author while realizing the existing problems to achieve this important task, has made efforts in this paper to justify this need and has proposed some criteria, in particular for the classification of natural radiation areas, based on a system of dose limitation. (author)

  9. Safety of dose escalation by simultaneous integrated boosting radiation dose within the primary tumor guided by 18FDG-PET/CT for esophageal cancer

    International Nuclear Information System (INIS)

    Yu, Wen; Cai, Xu-Wei; Liu, Qi; Zhu, Zheng-Fei; Feng, Wen; Zhang, Qin; Zhang, Ying-Jian; Yao, Zhi-Feng; Fu, Xiao-Long

    2015-01-01

    Purpose: To observe the safety of selective dose boost to the pre-treatment high 18 F-deoxyglucose (FDG) uptake areas of the esophageal GTV. Methods: Patients with esophageal squamous cell carcinoma were treated with escalating radiation dose of 4 levels, with a simultaneous integrated boost (SIB) to the pre-treatment 50% SUVmax area of the primary tumor. Patients received 4 monthly cycles of cisplatin and fluorouracil. Dose-limiting toxicity (DLT) was defined as any Grade 3 or higher acute toxicities causing continuous interruption of radiation for over 1 week. Results: From April 2012 to February 2014, dose has been escalated up to LEVEL 4 (70 Gy). All of the 25 patients finished the prescribed dose without DLT, and 10 of them developed Grade 3 acute esophagitis. One patient of LEVEL 2 died of esophageal hemorrhage within 1 month after completion of radiotherapy, which was not definitely correlated with treatment yet. Late toxicities remained under observation. With median follow up of 8.9 months, one-year overall survival and local control was 69.2% and 77.4%, respectively. Conclusions: Dose escalation in esophageal cancer based on 18 FDG-PET/CT has been safely achieved up to 70 Gy using the SIB technique. Acute toxicities were well tolerated, whereas late toxicities and long-term outcomes deserved further observation

  10. Low dose β-emitter source induces sexual reproduction instead of fragmentation in an earthworm, Enchytraeus japonensis

    International Nuclear Information System (INIS)

    Miyachi, Yukihisa; Kanao, Tomoko; Okamoto, Takehito

    2005-01-01

    We examined whether background radiation, or radiation at a slightly higher level, plays a role in the reproduction of a terrestrial earthworm. Enchytraeus japonensis a recently described terrestrial oligochaete, reproduces asexually by fragmentation and subsequent regeneration. Following radiation exposure in which the worms were subjected to a 32 P β-emitter source at 15 times the background dose rate (4.5 μGy/h), a statistically significant decrease in the number of fragmentations was observed as compared with the sham controls. At that time, in a stained preparation with haematoxylin and eosin (HE), sexual reproduction occurred instead of asexual fragmentation, and mature oocytes were observed in the body of grown worms. However, increasing the radiation dose rate by 30 μGy/h resulted in the complete disappearance of the radiation-induced effects, i.e., fragmentation again occurred after 14 h. The results of this study indicate that a lower dose of radiation may be essential to achieve sexual reproduction, inducing an inhibition of fragmentation (asexual reproduction), but at higher, more cytotoxic doses of radiation these effects are negated

  11. Radiation therapy and concurrent fixed dose amifostine with escalating doses of twice-weekly gemcitabine in advanced pancreatic cancer

    International Nuclear Information System (INIS)

    Yavuz, A. Aydin; Aydin, Fazil; Yavuz, Melek N.; Ilis, Esra; Ozdemir, Feyyaz

    2001-01-01

    Purpose: To determine the maximum tolerated dose (MTD) and dose-limiting toxicity (DLT) of twice-weekly gemcitabine (TW-G) when administered in conjunction with fixed dose amifostine (A) during external radiotherapy (RT) in patients with advanced pancreatic cancer. Methods and Materials: Ten patients with previously untreated, locally advanced, or asymptomatic-metastatic pancreatic adenocarcinoma were enrolled in this study. RT was delivered by using the standard four-field technique (1.8 Gy daily fractions, 45 Gy followed by a boost of 5.4 Gy, in 5-1/2 weeks). The starting dose of TW-G was 60 mg/m 2 (i.v., 30-min infusion), which is equal to the upper limit of previously reported MTD of TW-G when given without A during RT. A was given just before the TW-G, at a fixed dose of 340 mg/m 2 (i.v., rapid infusion). TW-G doses were escalated by 30-mg/m 2 increments in successive cohorts of 3 to 6 additional patients until DLT was observed. Toxicities were graded using the Radiation Therapy Oncology Group and National Cancer Institute Common Toxicity Criteria, version 2.0. Results: In general, therapy was well tolerated in patients treated at the first two dose levels of 60 mg/m 2 and 90 mg/m 2 . The DLT of TW-G given in conjunction with A during RT were neutropenia, thrombocytopenia, and nausea/vomiting at the dose level of 120 mg/m 2 . Of the 10 patients eligible for a median follow-up of 10 months, 5 remain alive; 1 complete responder, 3 partial responders, and 1 with stable disease. Conclusion: A dose of TW-G at a level of 90 mg/m 2 produced tolerable toxicity and it may possess significant activity when delivered in conjunction with 340 mg/m 2 dose of A during RT of the upper abdomen. Due to the higher MTD of TW-G seen in our study, we consider that the A supplementation may optimize the therapeutic index of TW-G-based chemoradiotherapy protocols in patients with pancreatic carcinoma

  12. Efficacy, safety and tolerability of escitalopram in doses up to 50 mg in Major Depressive Disorder (MDD: an open-label, pilot study

    Directory of Open Access Journals (Sweden)

    Crawford Gordon M

    2011-03-01

    Full Text Available Abstract Background Escitalopram is licensed for use at doses up to 20 mg but is used clinically at higher doses. There is limited published data at higher doses and none in the treatment of Major Depressive Disorder (MDD. Methods This open-label, pilot study was designed to investigate the efficacy, safety and tolerability of escitalopram in doses up to 50 mg in MDD. It was conducted in 60 primary care patients with MDD who had not responded to adequate treatment with citalopram. Patients were treated with escalating doses of escitalopram up to 50 mg for up to 32 weeks until they achieved remission (Montgomery-Asberg Depression Rating Scale [MADRS] ≤8 or failed to tolerate the dose. Results Forty-two patients (70% completed the study. Twenty-one patients (35% achieved remission with 8 of the 21 patients (38% needing the 50 mg dose to achieve remission. Median time to remission was 24 weeks and median dose in remission was 30 mg. No significant safety issues were identified although tolerability appeared to decline above a dose of 40 mg with 26% of patients unable to tolerate 50 mg. Twelve (20% patients had adverse events leading to discontinuation. The most common adverse events were headache (35%, nausea, diarrhoea and nasopharyngitis (all 25%. Minor mean weight gain was found during the study, which did not appear to be dose-related. Half of the patients who completed the study chose to continue treatment with escitalopram rather than taper down the dose at 32 weeks. Conclusions Dose escalation with escitalopram above 20 mg may have a useful role in the management of patients with MDD, although further studies are needed to confirm this finding. Trial Registration ClinicalTrials.gov: NCT00785434

  13. Laparoscopic cholecystectomy under spinal anesthesia: comparative study between conventional-dose and low-dose hyperbaric bupivacaine

    Directory of Open Access Journals (Sweden)

    Imbelloni LE

    2011-10-01

    Full Text Available Luiz Eduardo Imbelloni1, Raphael Sant'Anna2, Marcos Fornasari2, José Carlos Fialho21Department of Anesthesiology, Faculty of Medecine Nova Esperança, Hospital de Mangabeira, João Pessoa, 2Hospital Rio Laranjeiras, Rio de Janeiro, BrazilBackground: Laparoscopic cholecystectomy has the advantages of causing less postoperative pain and requiring a short hospital stay, and therefore is the treatment of choice for cholelithiasis. This study was designed to compare spinal anesthesia using hyperbaric bupivacaine given as a conventional dose by lumbar puncture or as a low-dose by thoracic puncture.Methods: A total of 140 patients with symptomatic gallstone disease were randomized to undergo laparoscopic cholecystectomy with low-pressure CO2 pneumoperitoneum under spinal anesthesia using either conventional lumbar spinal anesthesia (hyperbaric bupivacaine 15 mg and fentanyl 20 mg or low-dose thoracic spinal anesthesia (hyperbaric bupivacaine 7.5 mg and fentanyl 20 µg. Intraoperative parameters, postoperative pain, complications, recovery time, and patient satisfaction at follow-up were compared between the two treatment groups.Results: All procedures were completed under spinal anesthesia, with no cases needing conversion to general anesthesia. Values for time for block to reach the T3 dermatomal level, duration of motor and sensory block, and hypotensive events were significantly lower with low-dose bupivacaine. Postoperative pain was higher for low-dose hyperbaric bupivacaine at 6 and 12 hours. All patients were discharged after 24 hours. Follow-up 1 week postoperatively showed all patients to be satisfied and to be keen advocates of spinal anesthesia.Conclusion: Laparoscopic cholecystectomy can be performed successfully under spinal anesthesia. A small dose of hyperbaric bupivacaine 7.5 mg and 20 µg fentanyl provides adequate spinal anesthesia for laparoscopy and, in comparison with hyperbaric bupivacaine 15% and fentanyl 20 µg, causes markedly

  14. Health effects of low doses at low dose rates: dose-response relationship modeling in a cohort of workers of the nuclear industry

    International Nuclear Information System (INIS)

    Metz-Flamant, Camille

    2011-01-01

    The aim of this thesis is to contribute to a better understanding of the health effects of chronic external low doses of ionising radiation. This work is based on the French cohort of CEA-AREVA NC nuclear workers. The mains stages of this thesis were (1) conducting a review of epidemiological studies on nuclear workers, (2) completing the database and performing a descriptive analysis of the cohort, (3) quantifying risk by different statistical methods and (4) modelling the exposure-time-risk relationship. The cohort includes monitored workers employed more than one year between 1950 and 1994 at CEA or AREVA NC companies. Individual annual external exposure, history of work, vital status and causes of death were reconstructed for each worker. Standardized mortality ratios using French national mortality rates as external reference were computed. Exposure-risk analysis was conducted in the cohort using the linear excess relative risk model, based on both Poisson regression and Cox model. Time dependent modifying factors were investigated by adding an interaction term in the model or by using exposure time windows. The cohort includes 36, 769 workers, followed-up until age 60 in average. During the 1968- 2004 period, 5, 443 deaths, 2, 213 cancers, 62 leukemia and 1, 314 cardiovascular diseases were recorded. Among the 57% exposed workers, the mean cumulative dose was 21.5 milli-sieverts (mSv). A strong Healthy Worker Effect is observed in the cohort. Significant elevated risks of pleura cancer and melanoma deaths were observed in the cohort but not associated with dose. No significant association was observed with solid cancers, lung cancer and cardiovascular diseases. A significant dose-response relationship was observed for leukemia excluding chronic lymphatic leukemia, mainly for doses received less than 15 years before and for yearly dose rates higher than 10 mSv. This PhD work contributes to the evaluation of risks associated to chronic external radiation

  15. Stability of ferritic steel to higher doses: Survey of reactor pressure vessel steel data and comparison with candidate materials for future nuclear systems

    International Nuclear Information System (INIS)

    Blagoeva, D.T.; Debarberis, L.; Jong, M.; Pierick, P. ten

    2014-01-01

    This paper is illustrating the potential of the well-known low alloyed clean steels, extensively used for the current light water Reactor Pressure Vessels (RPV) steels, for a likely use as a structural material also for the new generation nuclear systems. This option would provide, especially for large components, affordable, easily accessible and a technically more convenient solution in terms of manufacturing and joining techniques. A comprehensive comparison between several sets of surveillance and research data available for a number of RPV clean steels for doses up to 1.5 dpa, and up to 12 dpa for 9%Cr steels, is carried out in order to evaluate radiation stability of the currently used RPV clean steels even at higher doses. Based on the numerous data available, positive preliminary conclusions are drawn regarding the eventual use of clean RPV steels for the massive structural components of the new reactor systems. - Highlights: • Common embrittlement trend between RPV and advanced steels till intermediate doses. • For doses >1.5 dpa, damage rate saturation tendency is observed for RPV steels. • RPV steels might be conveniently utilised also outside their foreseen dose range

  16. Comparison of ESD and major organ absorbed doses of 5 year old standard guidekines and clinical exposure conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kang, A Ram; Ahn, Sung Min [Dept. of Radiological Science, The Graduate School, Gachon University, Incheon (Korea, Republic of); Lee, In Ja [Dept. of Radiologic technology, Dongnam health University, Suwon (Korea, Republic of)

    2017-09-15

    Pediatrics are more sensibility to radiation than adults and because they are organs that are not completely grown, they have a life expectancy that can be adversely affected by exposure. Therefore, the management of exposure dose is more important than the case of adult. The purpose of this study was to determine the suitability of the 10 year old phantom for the 5 year old pediatric's recommendation and the incident surface dose, and to measure the organ absorbed dose. This study is compared the organ absorbed dose and the entrance surface dose in the clinical conditions at 5 and 10 years old pediatric. Clinical 5 year old condition was slightly higher than recommendation condition and 10 year old condition was very high. In addition, recommendation condition ESD was found to be 43% higher than the ESD of the 5 year old group and the ESD of the 10 year old group was 126% higher than that of the 5 year old group. The recommended ESD at 5 years old and the ESD according to clinical imaging conditions were 31.6%. There was no significant difference between the 5 year old recommended exposure conditions and the organ absorbed dose due to clinical exposure conditions, but there was a large difference between the Chest and Pelvic. However, it was found that there was a remarkable difference when comparing the organ absorbed dose by 10 year clinical exposure conditions. Therefore, more detailed standard exposure dose for the recommended dose of pediatric should be studied.

  17. Comparison of ESD and major organ absorbed doses of 5 year old standard guidekines and clinical exposure conditions

    International Nuclear Information System (INIS)

    Kang, A Ram; Ahn, Sung Min; Lee, In Ja

    2017-01-01

    Pediatrics are more sensibility to radiation than adults and because they are organs that are not completely grown, they have a life expectancy that can be adversely affected by exposure. Therefore, the management of exposure dose is more important than the case of adult. The purpose of this study was to determine the suitability of the 10 year old phantom for the 5 year old pediatric's recommendation and the incident surface dose, and to measure the organ absorbed dose. This study is compared the organ absorbed dose and the entrance surface dose in the clinical conditions at 5 and 10 years old pediatric. Clinical 5 year old condition was slightly higher than recommendation condition and 10 year old condition was very high. In addition, recommendation condition ESD was found to be 43% higher than the ESD of the 5 year old group and the ESD of the 10 year old group was 126% higher than that of the 5 year old group. The recommended ESD at 5 years old and the ESD according to clinical imaging conditions were 31.6%. There was no significant difference between the 5 year old recommended exposure conditions and the organ absorbed dose due to clinical exposure conditions, but there was a large difference between the Chest and Pelvic. However, it was found that there was a remarkable difference when comparing the organ absorbed dose by 10 year clinical exposure conditions. Therefore, more detailed standard exposure dose for the recommended dose of pediatric should be studied

  18. Biological effects of low doses of radiation at low dose rate

    International Nuclear Information System (INIS)

    1996-05-01

    The purpose of this report was to examine available scientific data and models relevant to the hypothesis that induction of genetic changes and cancers by low doses of ionizing radiation at low dose rate is a stochastic process with no threshold or apparent threshold. Assessment of the effects of higher doses of radiation is based on a wealth of data from both humans and other organisms. 234 refs., 26 figs., 14 tabs

  19. Evaluation of patient dose during computed tomography angiography

    International Nuclear Information System (INIS)

    Dafalla, Elamam Yagoob Taha

    2015-10-01

    Computed tomography (CT), is an x-ray procedure that generates high quality cross sectional images of the body, and by comparison to other radiological diagnosis, CT is responsible for higher doses to patients. The evaluation of patient dose from computed tomography for pulmonary examinations the CT is responsible for higher doses to patients. The radiation dose was measured in three hospitals in Khartoum State during March 2015-October 2015 using different CT modalities. The radiation dose was higher at Alzytouna hospital than Daralelaj hospital and Alatebaa hospital was lowest. In this study, the mean effective dose for first hospital was 23.83±3.93 mSv and the mean effective dose for second hospital was 8.94±1.64 mSv and the mean effective dose for third hospital was 2.96±0.79. (author)

  20. Who gets the most out of cognitive behavioral therapy for anxiety disorders? The role of treatment dose and patient engagement.

    Science.gov (United States)

    Glenn, Daniel; Golinelli, Daniela; Rose, Raphael D; Roy-Byrne, Peter; Stein, Murray B; Sullivan, Greer; Bystritksy, Alexander; Sherbourne, Cathy; Craske, Michelle G

    2013-08-01

    The present study explored treatment dose and patient engagement as predictors of treatment outcome in cognitive behavioral therapy (CBT) for anxiety disorders. Measures of high versus low treatment dose and high versus low patient engagement in CBT were compared as predictors of 12- and 18-month outcomes for patients being treated for anxiety disorders with CBT (with or without concurrent pharmacotherapy) in primary care settings as part of a randomized controlled effectiveness trial of the Coordinated Anxiety Learning and Management (CALM) intervention. Measures of dose (attendance, exposure completion) and engagement in CBT (homework adherence, commitment) were collected throughout treatment, and blinded follow-up phone assessments of outcome measures (12-item Brief Symptom Inventory, Patient Health Questionnaire 8, Sheehan Disability Scale) were completed at 12 and 18 months. Propensity score weighting controlled for baseline differences in demographics and symptom severity between patients with high and low dose and engagement. These analyses included the 439 patients who selected CBT as treatment modality. Completing exposures, having high attendance, and being more adherent to completing homework predicted better outcomes across all measures at 12 and 18 months, and high CBT commitment predicted better outcomes on all measures at 18 months. This study found that higher treatment dose and patient engagement in CBT for anxiety disorders were stable and robust predictors of greater reductions in anxiety symptoms, depression symptoms, and functional disability. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  1. Guidelines for Use of the Approximate Beta-Poisson Dose-Response Model.

    Science.gov (United States)

    Xie, Gang; Roiko, Anne; Stratton, Helen; Lemckert, Charles; Dunn, Peter K; Mengersen, Kerrie

    2017-07-01

    For dose-response analysis in quantitative microbial risk assessment (QMRA), the exact beta-Poisson model is a two-parameter mechanistic dose-response model with parameters α>0 and β>0, which involves the Kummer confluent hypergeometric function. Evaluation of a hypergeometric function is a computational challenge. Denoting PI(d) as the probability of infection at a given mean dose d, the widely used dose-response model PI(d)=1-(1+dβ)-α is an approximate formula for the exact beta-Poisson model. Notwithstanding the required conditions α1, issues related to the validity and approximation accuracy of this approximate formula have remained largely ignored in practice, partly because these conditions are too general to provide clear guidance. Consequently, this study proposes a probability measure Pr(0 (22α̂)0.50 for 0.020.99) . This validity measure and rule of thumb were validated by application to all the completed beta-Poisson models (related to 85 data sets) from the QMRA community portal (QMRA Wiki). The results showed that the higher the probability Pr(0 Poisson model dose-response curve. © 2016 Society for Risk Analysis.

  2. Enteroclysis and small bowel series: Comparison of radiation dose and examination time

    International Nuclear Information System (INIS)

    Thoeni, R.F.; Gould, R.G.

    1991-01-01

    Respective radiation doses and total examination and fluoroscopy times were compared for 50 patients; 25 underwent enteroclysis and 25 underwent small bowel series with (n = 17) and without (n = 8) an examination of the upper gastrointestinal (GI) tract. For enteroclysis, the mean skin entry radiation dose (12.3 rad [123 mGy]) and mean fluoroscopy time (18.4 minutes) were almost 1 1/2 times greater than those for the small bowel series with examination of the upper GI tract (8.4 rad [84 mGy]; 11.4 minutes) and almost three times greater than those for the small bowel series without upper GI examination (4.6 rad [46 mGy]; 6.3 minutes). However, the mean total examination completion time for enteroclysis (31.2 minutes) was almost half that of the small bowel series without upper GI examination (57.5 minutes) and almost four times shorter than that of the small bowel series with upper GI examination (114 minutes). The higher radiation dose of enteroclysis should be considered along with the short examination time, the age and clinical condition of the patient, and the reported higher accuracy when deciding on the appropriate radiographic examination of the small bowel

  3. The complete mitochondrial genome of Gossypium hirsutum and evolutionary analysis of higher plant mitochondrial genomes.

    Science.gov (United States)

    Liu, Guozheng; Cao, Dandan; Li, Shuangshuang; Su, Aiguo; Geng, Jianing; Grover, Corrinne E; Hu, Songnian; Hua, Jinping

    2013-01-01

    Mitochondria are the main manufacturers of cellular ATP in eukaryotes. The plant mitochondrial genome contains large number of foreign DNA and repeated sequences undergone frequently intramolecular recombination. Upland Cotton (Gossypium hirsutum L.) is one of the main natural fiber crops and also an important oil-producing plant in the world. Sequencing of the cotton mitochondrial (mt) genome could be helpful for the evolution research of plant mt genomes. We utilized 454 technology for sequencing and combined with Fosmid library of the Gossypium hirsutum mt genome screening and positive clones sequencing and conducted a series of evolutionary analysis on Cycas taitungensis and 24 angiosperms mt genomes. After data assembling and contigs joining, the complete mitochondrial genome sequence of G. hirsutum was obtained. The completed G.hirsutum mt genome is 621,884 bp in length, and contained 68 genes, including 35 protein genes, four rRNA genes and 29 tRNA genes. Five gene clusters are found conserved in all plant mt genomes; one and four clusters are specifically conserved in monocots and dicots, respectively. Homologous sequences are distributed along the plant mt genomes and species closely related share the most homologous sequences. For species that have both mt and chloroplast genome sequences available, we checked the location of cp-like migration and found several fragments closely linked with mitochondrial genes. The G. hirsutum mt genome possesses most of the common characters of higher plant mt genomes. The existence of syntenic gene clusters, as well as the conservation of some intergenic sequences and genic content among the plant mt genomes suggest that evolution of mt genomes is consistent with plant taxonomy but independent among different species.

  4. Long-Term Results of Fixed High-Dose I-131 Treatment for Toxic Nodular Goiter: Higher Euthyroidism Rates in Geriatric Patients

    Directory of Open Access Journals (Sweden)

    Gül Ege Aktaş

    2015-10-01

    Full Text Available Objective: Geriatric patient population has special importance due to particular challenges. In addition to the increase in incidence of toxic nodular goiter (TNG with age, it has a high incidence in the regions of low-medium iodine intake such as in our country. The aim of this study was to evaluate the overall outcome of high fixed dose radioiodine (RAI therapy, and investigate the particular differences in the geriatric patient population. Methods: One hundred and three TNG patients treated with high dose I-131 (370-740 MBq were retrospectively reviewed. The baseline characteristics; age, gender, scintigraphic patterns and thyroid function tests before and after treatment, as well as follow-up, duration of antithyroid drug (ATD medication and achievement of euthyroid or hypothyroid state were evaluated. The patient population was divided into two groups as those=>65 years and those who were younger, in order to assess the effect of age. Results: Treatment success was 90% with single dose RAI therapy. Hyperthyroidism was treated in 7±7, 2 months after RAI administration. At the end of the first year, overall hypothyroidism rate was 30% and euthyroid state was achieved in 70% of patients. Age was found to be the only statistically significant variable effecting outcome. A higher ratio of euthyroidism was achieved in the geriatric patient population. Conclusion: High fixed dose I-131 treatment should be preferred in geriatric TNG patients in order to treat persistent hyperthyroidism rapidly. The result of this study suggests that high fixed dose RAI therapy is a successful modality in treating TNG, and high rates of euthyroidism can be achieved in geriatric patients.

  5. ESTIMATION OF THE CONVERSION COEFFICIENTS FROM DOSE-AREA PRODUCT TO EFFECTIVE DOSE FOR BARIUM MEAL EXAMINATIONS FOR ADULT PATIENTS

    Directory of Open Access Journals (Sweden)

    A. V. Vodovatov

    2018-01-01

    Full Text Available Fluoroscopic examinations of the upper gastro-intestinal tract and, especially, barium meal examinations, are commonly performed in a majority of hospitals. These examinations are associated both with substantial individual patient doses and contribution to the collective dose from medical exposure. Effective dose estimation for this type of examinations is complicated due to: 1 the necessity to simulate the moving X-ray irradiation field; 2 differences in study structure for the individual patients; 3 subjectivity of the operators; and 4 differences in the X-ray equipment. The aim of the current study was to estimate conversion coefficients from dose-area product to effective dose for barium meal examinations for the over couch and under couch exposure conditions. The study was based on data collected in the X-ray unit of the surgical department of the St-Petersburg Mariinsky hospital. A model of patient exposure during barium meal examination was developed based on the collected data on fluoroscopy protocols and adult patient irradiation geometry. Conversion coefficients were calculated using PCXMC 2.0 software. Complete examinations were converted into a set of typical fluoroscopy phases and X-ray images, specified by the examined anatomical region and the projection of patient exposure. Conversion coefficients from dose-area product to effective dose were calculated for each phase of the examination and for the complete examination. The resulting values of the conversion coefficients are comparable with published data. Variations in the absolute values of the conversion coefficients can be explained by differences in clinical protocols, models for the estimation of the effective dose and parameters of barium meal examinations. The proposed approach for estimation of effective dose considers such important features of fluoroscopic examinations as: 1 non-uniform structure of examination, 2 significant movement of the X-ray tube within a single

  6. Effects of oxygen and TMPN on the initial part of the dose-effect curves of human cells in culture

    International Nuclear Information System (INIS)

    Pettersen, E.O.; Wibe, E.; Lovhaug, D.; Oftebro, R.; Brustad, T.

    1975-01-01

    Human cells of the established cell line NHIK 3025 have been irradiated under various conditions of oxygen and TMPN concentrations. Complete survival curves are presented for each concentration of both oxygen and TMPN. The survival curves for extremely hypoxic cells in the absence of TMPN were found to be strictly exponential in the dose range below about 2300 rad, irrespective of the technique used. Oxygen at a concentration of 37 ppm was found to protect the cells at least above the dose range up to 2500 rad, while 250 ppm of oxygen exerted a protective effect in the dose range below 1200 rad and a sensitizing effect (OER = 1.43) for higher doses. However, the protective effect below 700 rad was found to be higher in the presence of 250 ppm O 2 , than 37 ppm O 2 , indicating that the degree of protection in this low-dose range is optimal for an oxygen concentration higher than 37 ppm. TMPN provides a protective and a sensitizing effect in about the same way as oxygen does, but TMPN is less effective. When the TMPN concentration is increased from 0.5 to 10 mM the maximum dose for which TMPN exerts a protective effect on the hypoxic cells decreases from 700 to 400 rad. However the degree of protection in the dose range below 300 rad is higher for TMPN concentrations of 1 mM and 3 mM than for 0.5 mM and 10 mM. Results indicate that the degree of protection is optimal in the low-dose range (< 300 rad) for a TMPN concentration somewhere between 0.5 mM and 3 mM. (author)

  7. Radiation Dose-Response Model for Locally Advanced Rectal Cancer After Preoperative Chemoradiation Therapy

    International Nuclear Information System (INIS)

    Appelt, Ane L.; Pløen, John; Vogelius, Ivan R.; Bentzen, Søren M.; Jakobsen, Anders

    2013-01-01

    Purpose: Preoperative chemoradiation therapy (CRT) is part of the standard treatment of locally advanced rectal cancers. Tumor regression at the time of operation is desirable, but not much is known about the relationship between radiation dose and tumor regression. In the present study we estimated radiation dose-response curves for various grades of tumor regression after preoperative CRT. Methods and Materials: A total of 222 patients, treated with consistent chemotherapy and radiation therapy techniques, were considered for the analysis. Radiation therapy consisted of a combination of external-beam radiation therapy and brachytherapy. Response at the time of operation was evaluated from the histopathologic specimen and graded on a 5-point scale (TRG1-5). The probability of achieving complete, major, and partial response was analyzed by ordinal logistic regression, and the effect of including clinical parameters in the model was examined. The radiation dose-response relationship for a specific grade of histopathologic tumor regression was parameterized in terms of the dose required for 50% response, D 50,i , and the normalized dose-response gradient, γ 50,i . Results: A highly significant dose-response relationship was found (P=.002). For complete response (TRG1), the dose-response parameters were D 50,TRG1 = 92.0 Gy (95% confidence interval [CI] 79.3-144.9 Gy), γ 50,TRG1 = 0.982 (CI 0.533-1.429), and for major response (TRG1-2) D 50,TRG1 and 2 = 72.1 Gy (CI 65.3-94.0 Gy), γ 50,TRG1 and 2 = 0.770 (CI 0.338-1.201). Tumor size and N category both had a significant effect on the dose-response relationships. Conclusions: This study demonstrated a significant dose-response relationship for tumor regression after preoperative CRT for locally advanced rectal cancer for tumor dose levels in the range of 50.4-70 Gy, which is higher than the dose range usually considered.

  8. Are high doses of carbidopa a concern? A randomized clinical trial in Parkinson’s disease

    Science.gov (United States)

    Brod, Lissa S.; Aldred, Jason L.; Nutt, John G.

    2013-01-01

    Background Recommended doses of carbidopa are 75–200 mg/day. Higher doses could inhibit brain aromatic amino acid decarboxylase and reduce clinical effects. Methods We compared 4-week outpatient treatments with carbidopa 75 mg and 450 mg/day administered with levodopa on the subjects’ normal schedule. After each treatment phase subjects had two 2-hour levodopa infusions. The first infusion examined the effects of carbidopa doses administered the preceding four weeks and the second infusion determined the acute effects of the two dosages of carbidopa. The antiparkinsonian effects and levodopa and carbidopa plasma concentrations were monitored during the infusions. Results Twelve subjects completed the study. Carbidopa concentrations were eight times higher after the high carbidopa phase. Area under the curve (AUC) for clinical ratings did not differ for the four levodopa infusions although AUC for plasma levodopa was modestly increased with 450 mg of carbidopa. Nine subjects reported the high carbidopa outpatient phase was associated with greater response to levodopa. Conclusion Doses of 450 mg/day of carbidopa did not reduce the responses to levodopa infusion, extending the safe range of carbidopa to 450 mg/day. PMID:22508376

  9. The effects of a priming dose of alcohol and drinking environment on snack food intake.

    Science.gov (United States)

    Rose, A K; Hardman, C A; Christiansen, P

    2015-12-01

    Alcohol consumption is a potential risk factor for being overweight. We aimed to investigate the effects of an alcohol priming dose and an alcohol-related environment on snacking behaviour. One hundred and fourteen social drinkers completed one of four experimental sessions either receiving a priming dose of alcohol (.6 g/kg) or soft drink in a bar-lab or a sterile lab. Participants provided ratings of appetite, snack urge, and alcohol urge before and after consuming their drinks. Participants completed an ad libitum snack taste test of savoury and sweet, healthy and unhealthy foods before completing the self-reports a final time. Appetite and snack urge increased more following alcohol consumption, and decreased to a lesser extent following the taste test relative to the soft drink. Total calories (including drink calories) consumed were significantly higher in the alcohol groups. There was a marginal effect of environment; those in the bar-lab consumed a higher proportion of unhealthy foods. These effects were more pronounced in those who were disinhibited. While alcohol may not increase food consumption per se, alcohol may acutely disrupt appetite signals, perhaps via processes of reward and inhibitory control, resulting in overall greater calorie intake. Individuals who are generally disinhibited may be more vulnerable to the effects of alcohol and drinking environments on eating behaviour. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Evaluating higher doses of Shunthi - Guduchi formulations for safety in treatment of osteoarthritis knees: A Government of India NMITLI arthritis project

    OpenAIRE

    Arvind Chopra; Manjit Saluja; Girish Tillu; Anuradha Venugopalan; Gumdal Narsimulu; Sanjeev Sarmukaddam; Bhushan Patwardhan

    2012-01-01

    Background: Results of an exploratory trial suggested activity trends of Zingiber officinale-Tinopsora cordifolia (platform combination)-based formulations in the treatment of Osteoarthritis (OA) Knees. These formulations were "platform combination+Withania somnifera+Tribulus terrestris0" (formulation B) and "platform combination+Emblica officinale" (formulation C). This paper reports safety of these formulations when used in higher doses (1.5-2 times) along with Sallaki Guggul and Bhallataka...

  11. Lifetime radiation risks from low-dose rate radionuclides in beagles

    International Nuclear Information System (INIS)

    Goldman, M.; Rosenblatt, L.S.

    1985-01-01

    One of the largest, long-term (25-yr) animal studies on the effects of low-dose internal irradiation is almost completed. Some 335 beagles were given continuous exposure to graded 90 Sr [low linear energy transfer (LET)] in their diets (D-dogs) through adulthood. A second group (R-dogs) was given fractionated doses of 225 Ra (high LET) as young adults. A third group of 44 was given a single injection of 90 Sr as adults (S-dogs) to compare single to continuous dosages. All dogs were followed through their lifetimes. Only one of the 848 dogs is still alive. The animals were whole-body counted over their entire life span and were examined frequently for assessment of medical status. There were no acute radiation lethalities. Analyses of the large data base from these dogs have begun and preliminary indications are that 90 Sr, which was tested over a 1500-fold skeletal dose rate range, does not cause significant life shortening at average accumulation skeletal doses of ∼2500 rads (25 Gy) and that a curvilinear dose response curve for life shortening was seen at higher accumulation doses. The data will be discussed in terms of modern epidemiological concepts and quantifications will be related to certain parameters of human risk from acute or chronic radiation exposures

  12. High-dose-rate brachytherapy in the treatment of uterine cervix cancer. Analysis of dose effectiveness and late complications

    International Nuclear Information System (INIS)

    Ferrigno, Robson; Novaes, Paulo Eduardo Ribeiro dos Santos; Pellizzon, Antonio Cassio Assis; Maia, Maria Aparecida Conte; Fogarolli, Ricardo Cesar; Gentil, Andre Cavalcanti; Salvajoli, Joao Victor

    2001-01-01

    Purpose: This retrospective analysis aims to report results of patients with cervix cancer treated by external beam radiotherapy (EBR) and high-dose-rate (HDR) brachytherapy. Methods and Materials: From September 1992 to December 1996, 138 patients with FIGO Stages II and III and mean age of 56 years were treated. Median EBR to the whole pelvis was 45 Gy in 25 fractions. Parametrial boost was performed in 93% of patients, with a median dose of 14.4 Gy. Brachytherapy with HDR was performed during EBR or following its completion with a dose of 24 Gy in four weekly fractions of 6 Gy to point A. Median overall treatment time was of 60 days. Patient age, tumor stage, and overall treatment time were variables analyzed for survival and local control. Cumulative biologic effective dose (BED) at rectal and bladder reference points were correlated with late complications in these organs and dose of EBR at parametrium was correlated with small bowel complications. Results: Median follow-up time was 38 months. Overall survival, disease-free survival, and local control at 5 years was 53.7%, 52.7%, and 62%, respectively. By multivariate and univariate analysis, overall treatment time up to 50 days was the only statistically significant adverse variable for overall survival (p=0.003) and actuarial local control (p=0.008). The 5-year actuarial incidence of rectal, bladder, and small bowel late complications was 16%, 11%, and 14%, respectively. Patients treated with cumulative BED at rectum points above 110 Gy 3 and at bladder point above 125 Gy 3 had a higher but not statistically significant 5-year actuarial rate of complications at these organs (18% vs. 12%, p=0.49 and 17% vs. 9%, p=0.20, respectively). Patients who received parametrial doses larger than 59 Gy had a higher 5-year actuarial rate of complications in the small bowel; however, this was not statistically significant (19% vs. 10%, p=0.260). Conclusion: This series suggests that 45 Gy to the whole pelvis combined with

  13. Optimizing cancer radiotheraphy with 2-deoxy-D-glucose. Dose escalation studies in patients with glioblastoma multiforme

    Energy Technology Data Exchange (ETDEWEB)

    Singh, D.; Gupta, J.P. [Dharmshila Cancer Hospital, New Delhi (India); Banerji, A.K. [Vidyasagar Inst. of Mental Health and Neurosciences, New Delhi (India); Dwarakanath, B.S.; Tripathi, R.P.; Mathew, T.L.; Ravindranath, T. [Institute of Nuclear Medicine and Allied Sciences, Delhi (India); Jain, V. [Wright State University, Dayton, OH (United States). Kettering Medical Center

    2005-08-01

    Background and purpose: Higher rates of glucose utilization and glycolysis generally correlate with poor prognosis in several types of malignant tumors. Own earlier studies on model systems demonstrated that the nonmetabolizable glucose analog 2-deoxy-D-glucose (2-DG) could enhance the efficacy of radiotherapy in a dose-dependent manner by selectively sensitizing cancer cells while protecting normal cells. Phase I/II clinical trials indicated that the combination of 2-DG, at an oral dose of 200 mg/kg body weight (BW), with large fractions of {gamma}-radiation was well tolerated in cerebral glioma patients. Since higher 2-DG doses are expected to improve the therapeutic gain, present studies were undertaken to examine the tolerance and safety of escalating 2-DG dose during combined treatment (2-DG + radiotherapy) in glioblastoma multiforme patients. Patients and methods: Untreated patients with histologically proven glioblastoma multiforme (WHO criteria) were included in the study. Seven weekly fractions of {sup 60}C {gamma}-rays (5 Gy/fraction) were delivered to the tumor volume (presurgical CT/MRI evaluation) plus 3 cm margin. Escalating 2-DG doses (200-250-300 mg/kg BW) were administered orally 30 min before irradiation after overnight fasting. Acute toxicity and tolerance were studied by monitoring the vital parameters and side effects. Late radiation damage and treatment responses were studied radiologically and clinically in surviving patients. Results: Transient side effects similar to hypoglycemia were observed in most of the patients. Tolerance and patient compliance to the combined treatment were very good up to a 2-DG dose of 250 mg/kg BW. However, at the higher dose of 300 mg/kg BW, two out of six patients were very restless and could not complete treatment, though significant changes in the vital parameters were not observed even at this dose. No significant damage to the normal brain tissue was observed during follow-up in seven out of ten patients who

  14. Accuracy of Digitally Fabricated Wax Denture Bases and Conventional Completed Complete Dentures

    Directory of Open Access Journals (Sweden)

    Bogna Stawarczyk

    2017-12-01

    Full Text Available The purpose of this investigation was to analyze the accuracy of digitally fabricated wax trial dentures and conventionally finalized complete dentures in comparison to a surface tessellation language (STL-dataset. A generated data set for the denture bases and the tooth sockets was used, converted into STL-format, and saved as reference. Five mandibular and 5 maxillary denture bases were milled from wax blanks and denture teeth were waxed into their tooth sockets. Each complete denture was checked on fit, waxed onto the dental cast, and digitized using an optical laboratory scanning device. The complete dentures were completed conventionally using the injection method, finished, and scanned. The resulting STL-datasets were exported into the three-dimensional (3D software GOM Inspect. Each of the 5 mandibular and 5 maxillary complete dentures was aligned with the STL- and the wax trial denture dataset. Alignment was performed based on a best-fit algorithm. A three-dimensional analysis of the spatial divergences in x-, y- and z-axes was performed by the 3D software and visualized in a color-coded illustration. The mean positive and negative deviations between the datasets were calculated automatically. In a direct comparison between maxillary wax trial dentures and complete dentures, complete dentures showed higher deviations from the STL-dataset than the wax trial dentures. The deviations occurred in the area of the teeth as well as in the distal area of the denture bases. In contrast, the highest deviations in both the mandibular wax trial dentures and the mandibular complete dentures were observed in the distal area. The complete dentures showed higher deviations on the occlusal surfaces of the teeth compared to the wax dentures. Computer-aided design/computer-aided manufacturing (CAD/CAM-fabricated wax dentures exhibited fewer deviations from the STL-reference than the complete dentures. The deviations were significantly greater in the

  15. Optimized dose distribution of a high dose rate vaginal cylinder

    International Nuclear Information System (INIS)

    Li Zuofeng; Liu, Chihray; Palta, Jatinder R.

    1998-01-01

    Purpose: To present a comparison of optimized dose distributions for a set of high-dose-rate (HDR) vaginal cylinders calculated by a commercial treatment-planning system with benchmark calculations using Monte-Carlo-calculated dosimetry data. Methods and Materials: Optimized dose distributions using both an isotropic and an anisotropic dose calculation model were obtained for a set of HDR vaginal cylinders. Mathematical optimization techniques available in the computer treatment-planning system were used to calculate dwell times and positions. These dose distributions were compared with benchmark calculations with TG43 formalism and using Monte-Carlo-calculated data. The same dwell times and positions were used for a quantitative comparison of dose calculated with three dose models. Results: The isotropic dose calculation model can result in discrepancies as high as 50%. The anisotropic dose calculation model compared better with benchmark calculations. The differences were more significant at the apex of the vaginal cylinder, which is typically used as the prescription point. Conclusion: Dose calculation models available in a computer treatment-planning system must be evaluated carefully to ensure their correct application. It should also be noted that when optimized dose distribution at a distance from the cylinder surface is calculated using an accurate dose calculation model, the vaginal mucosa dose becomes significantly higher, and therefore should be carefully monitored

  16. The impact of the oxygen scavenger on the dose-rate dependence and dose sensitivity of MAGIC type polymer gels

    Science.gov (United States)

    Khan, Muzafar; Heilemann, Gerd; Kuess, Peter; Georg, Dietmar; Berg, Andreas

    2018-03-01

    Recent developments in radiation therapy aimed at more precise dose delivery along with higher dose gradients (dose painting) and more efficient dose delivery with higher dose rates e.g. flattening filter free (FFF) irradiation. Magnetic-resonance-imaging based polymer gel dosimetry offers 3D information for precise dose delivery techniques. Many of the proposed polymer gels have been reported to exhibit a dose response, measured as relaxation rate ΔR2(D), which is dose rate dependent. A lack of or a reduced dose-rate sensitivity is very important for dosimetric accuracy, especially with regard to the increasing clinical use of FFF irradiation protocols with LINACs at high dose rates. Some commonly used polymer gels are based on Methacrylic-Acid-Gel-Initiated-by-Copper (MAGIC). Here, we report on the dose sensitivity (ΔR2/ΔD) of MAGIC-type gels with different oxygen scavenger concentration for their specific dependence on the applied dose rate in order to improve the dosimetric performance, especially for high dose rates. A preclinical x-ray machine (‘Yxlon’, E  =  200 kV) was used for irradiation to cover a range of dose rates from low \\dot{D} min  =  0.6 Gy min-1 to high \\dot{D} max  =  18 Gy min-1. The dose response was evaluated using R2-imaging of the gel on a human high-field (7T) MR-scanner. The results indicate that all of the investigated dose rates had an impact on the dose response in polymer gel dosimeters, being strongest in the high dose region and less effective for low dose levels. The absolute dose rate dependence \\frac{(Δ R2/Δ D)}{Δ \\dot{D}} of the dose response in MAGIC-type gel is significantly reduced using higher concentrations of oxygen scavenger at the expense of reduced dose sensitivity. For quantitative dose evaluations the relative dose rate dependence of a polymer gel, normalized to its sensitivity is important. Based on this normalized sensitivity the dose rate sensitivity was reduced distinctly

  17. Retrospective analysis of bendamustine and rituximab use in indolent and mantle cell non-Hodgkin lymphoma based on initial starting dose.

    Science.gov (United States)

    Bond, David A; Huang, Ying; Ruppert, Amy S; Walker, Alison R; Dotson, Emily K; Roddy, Julianna; Blum, Kristie A; Christian, Beth A

    2017-07-01

    The initial dose of bendamustine, an alkylating agent used in treating indolent lymphoma (iNHL) and mantle cell lymphoma, is variable in clinical practice. 134 patients treated with bendamustine and rituximab were evaluated for starting dosage, patient characteristics, toxicities, and clinical outcome. The starting dosage ranged from 50 to 90 mg/m 2 . Lower starting dosage (<90 mg/m 2 ) was associated with relapsed disease, increased age and worse performance status (PS), histologic subtype other than follicular lymphoma, baseline renal impairment, and cytopenias. No significant difference was observed in toxicities between patients treated with 90 mg/m 2 compared with lower doses. The starting dose of 90 mg/m 2 was associated with a higher complete response rate (56% vs. 29%) and longer progression free survival (PFS) (39.5 months vs. 19.7 months). However, in a multivariable model, the higher starting dose was not associated with longer PFS in those with similar age, histology, PS, and number of prior therapies.

  18. Semi-Supervised Tripled Dictionary Learning for Standard-dose PET Image Prediction using Low-dose PET and Multimodal MRI

    Science.gov (United States)

    Wang, Yan; Ma, Guangkai; An, Le; Shi, Feng; Zhang, Pei; Lalush, David S.; Wu, Xi; Pu, Yifei; Zhou, Jiliu; Shen, Dinggang

    2017-01-01

    Objective To obtain high-quality positron emission tomography (PET) image with low-dose tracer injection, this study attempts to predict the standard-dose PET (S-PET) image from both its low-dose PET (L-PET) counterpart and corresponding magnetic resonance imaging (MRI). Methods It was achieved by patch-based sparse representation (SR), using the training samples with a complete set of MRI, L-PET and S-PET modalities for dictionary construction. However, the number of training samples with complete modalities is often limited. In practice, many samples generally have incomplete modalities (i.e., with one or two missing modalities) that thus cannot be used in the prediction process. In light of this, we develop a semi-supervised tripled dictionary learning (SSTDL) method for S-PET image prediction, which can utilize not only the samples with complete modalities (called complete samples) but also the samples with incomplete modalities (called incomplete samples), to take advantage of the large number of available training samples and thus further improve the prediction performance. Results Validation was done on a real human brain dataset consisting of 18 subjects, and the results show that our method is superior to the SR and other baseline methods. Conclusion This work proposed a new S-PET prediction method, which can significantly improve the PET image quality with low-dose injection. Significance The proposed method is favorable in clinical application since it can decrease the potential radiation risk for patients. PMID:27187939

  19. Clarithromycin (Biaxin)-lenalidomide-low-dose dexamethasone (BiRd) versus lenalidomide-low-dose dexamethasone (Rd) for newly diagnosed myeloma.

    Science.gov (United States)

    Gay, Francesca; Rajkumar, S Vincent; Coleman, Morton; Kumar, Shaji; Mark, Tomer; Dispenzieri, Angela; Pearse, Roger; Gertz, Morie A; Leonard, John; Lacy, Martha Q; Chen-Kiang, Selina; Roy, Vivek; Jayabalan, David S; Lust, John A; Witzig, Thomas E; Fonseca, Rafael; Kyle, Robert A; Greipp, Philip R; Stewart, A Keith; Niesvizky, Ruben

    2010-09-01

    The objective of this case-matched study was to compare the efficacy and toxicity of the addition of clarithromycin (Biaxin) to lenalidomide/low-dose dexamethasone (BiRd) vs. lenalidomide/low-dose dexamethasone (Rd) for newly diagnosed myeloma. Data from 72 patients treated at the New York Presbyterian Hospital-Cornell Medical Center were retrospectively compared with an equal number of matched pair mates selected among patients seen at the Mayo Clinic who received Rd. Case matching was blinded and was performed according to age, gender, and transplant status. On intention-to-treat analysis, complete response (45.8% vs. 13.9%, P < 0.001) and very-good-partial-response or better (73.6% vs. 33.3%, P < 0.001) were significantly higher with BiRd. Time-to-progression (median 48.3 vs. 27.5 months, P = 0.071), and progression-free survival (median 48.3 vs. 27.5 months, P = 0.044) were higher with BiRd. There was a trend toward better OS with BiRd (3-year OS: 89.7% vs. 73.0%, P = 0.170). Main grade 3-4 toxicities of BiRd were hematological, in particular thrombocytopenia (23.6% vs. 8.3%, P = 0.012). Infections (16.7% vs. 9.7%, P = 0.218) and dermatological toxicity (12.5% vs. 4.2%, P = 0.129) were higher with Rd. Results of this case-matched analysis suggest that there is significant additive value when clarithromycin is added to Rd. Randomized phase III trials are needed to confirm these results. © 2010 Wiley-Liss, Inc.

  20. Geometrical Sparing Factors for the Rectum and Bladder in the Prediction of Grade 2 and Higher Complications After High-Dose-Rate Brachytherapy for Cervical Cancer

    International Nuclear Information System (INIS)

    Chen, S.-W.; Liang, J.-A.; Hung, Y.-C.; Yeh, L.-S.; Chang, W.-C.; Yang, S.-N.; Lin, F.-J.

    2009-01-01

    Purpose: This study aimed to assess the predictive values of geometrical sparing factors for the rectum and bladder in high-dose-rate intracavitary brachytherapy (HDRICB) for Grade 2 and higher late sequelae in patients with cervical cancer. Methods: A total of 392 patients were enrolled in this study. They were treated with external beam radiotherapy to the pelvis, after which HDRICB was performed using Ir-192 remote after-loading at 1-week intervals for three or four sessions. The geometrical sparing factor (GSF) was defined as the average of the ratios between the reference doses and the Point A dose. Results: A total of 46 patients (11.7%) had Grade 2 or higher late rectal complications (36 Grade 2, 9 Grade 3, and 1 Grade 4). In all, 32 patients (8.2%) had Grade 2 or higher late bladder complications (14 Grade 2, 16 Grade 3, and 2 Grade 4). Multivariate analysis demonstrated a high risk of rectal sequelae in patients who developed bladder complications (p = 0.0004, hazard ratio 3.54) and had a rectal GSF greater than 0.7 (p = 0.01, hazard ratio 1.99). The high risk factors for bladder complications were development of rectal complications (p = 0.0004, hazard ratio 3.74), concurrent chemotherapy (p = 0.0001, relative risk 3.94), and a bladder GSF greater than 0.9 (p = 0.01, hazard ratio, 2.53). Conclusion: This study demonstrates the predictive value of GSFs in HDRICB for cervical cancer. Patients with rectal GSFs greater than 0.7 or bladder GSFs greater than 0.9 are at risk for Grade 2 and higher late sequelae.

  1. Geometrical sparing factors for the rectum and bladder in the prediction of grade 2 and higher complications after high-dose-rate brachytherapy for cervical cancer.

    Science.gov (United States)

    Chen, Shang-Wen; Liang, Ji-An; Hung, Yao-Ching; Yeh, Lian-Shung; Chang, Wei-Chun; Yang, Shih-Neng; Lin, Fang-Jen

    2009-12-01

    This study aimed to assess the predictive values of geometrical sparing factors for the rectum and bladder in high-dose-rate intracavitary brachytherapy (HDRICB) for Grade 2 and higher late sequelae in patients with cervical cancer. A total of 392 patients were enrolled in this study. They were treated with external beam radiotherapy to the pelvis, after which HDRICB was performed using Ir-192 remote after-loading at 1-week intervals for three or four sessions. The geometrical sparing factor (GSF) was defined as the average of the ratios between the reference doses and the Point A dose. A total of 46 patients (11.7%) had Grade 2 or higher late rectal complications (36 Grade 2, 9 Grade 3, and 1 Grade 4). In all, 32 patients (8.2%) had Grade 2 or higher late bladder complications (14 Grade 2, 16 Grade 3, and 2 Grade 4). Multivariate analysis demonstrated a high risk of rectal sequelae in patients who developed bladder complications (p = 0.0004, hazard ratio 3.54) and had a rectal GSF greater than 0.7 (p = 0.01, hazard ratio 1.99). The high risk factors for bladder complications were development of rectal complications (p = 0.0004, hazard ratio 3.74), concurrent chemotherapy (p = 0.0001, relative risk 3.94), and a bladder GSF greater than 0.9 (p = 0.01, hazard ratio, 2.53). This study demonstrates the predictive value of GSFs in HDRICB for cervical cancer. Patients with rectal GSFs greater than 0.7 or bladder GSFs greater than 0.9 are at risk for Grade 2 and higher late sequelae.

  2. The effect of obesity on pathological complete response and survival in breast cancer patients receiving uncapped doses of neoadjuvant anthracycline-taxane-based chemotherapy.

    Science.gov (United States)

    Farr, Alex; Stolz, Myriam; Baumann, Lukas; Bago-Horvath, Zsuzsanna; Oppolzer, Elisabeth; Pfeiler, Georg; Seifert, Michael; Singer, Christian F

    2017-06-01

    The effect of obesity in breast cancer patients undergoing neoadjuvant chemotherapy (NAC) remains controversial. The aim of this study was to determine the obesity-related effect on pathological complete response (pCR) and survival in women receiving full uncapped doses of NAC. We retrospectively analyzed the data of all consecutive women who underwent anthracycline-taxane-based NAC for primary breast cancer between 2005 and 2015 at the Department of Obstetrics and Gynecology, Medical University of Vienna. Following the WHO criteria, women with a body mass index (BMI) ≥30 kg/m 2 at baseline were considered obese, whereas those with a BMI <30 kg/m 2 were considered non-obese. Those with dose reductions or dose capping were not eligible for study inclusion. Cox regression and logistic regression were performed. The Kaplan-Meier method was used to analyze disease-free, progression-free, and overall survival. The pCR served as the main outcome measure. Among 120 women who received neoadjuvant epirubicin plus cyclophosphamide and docetaxel, 28 (23.3%) were obese and 92 (76.7%) were non-obese. In the multivariate logistic regression model that adjusted for potentially confounding variables, obesity had an independent positive predictive effect on pCR (OR 4.29, 95% CI, 1.42-13.91; p = 0.011), which was significant in the postmenopausal subgroup (OR 4.72, 95% CI, 1.47-15.84; p = 0.01). When comparing non-obese with obese women, we found that obese women experienced longer progression-free survival (HR 0.10, 95% CI, 8.448 × 10 -4 -0.81; p = 0.025). Obese women receiving full uncapped doses of anthracycline-taxane-based NAC have increased pCR and favorable progression-free survival. This could result from increased dose intensity with increased efficacy and toxicity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Nuclear medicine external individual occupational doses in Rio de Janeiro

    International Nuclear Information System (INIS)

    Mauricio, Claudia L.P.; Lima, Ana Luiza S.; Silva, Herica L.R. da; Santos, Denison Souza; Silva, Claudio Ribeiro da

    2009-01-01

    According to the Brazilian National Database there are about 300 Nuclear Medicine Services (NMS) in Brazil, 44 of them located in the State of Rio de Janeiro (RJ). Individual dose measurements are an important input for the evaluation of occupational exposure in order to demonstrate the effectiveness of radioprotection implementation and to keep individual doses as low as possible. In Brazil, most nuclear medicine (NM) staff is routinely monitored for external dose. The internal committed dose is estimated only in abnormal conditions. This paper makes a statistics analysis of all the RJ NMS annual external occupational doses in year 2005. A study of the evolution of monthly external individual doses higher than 4.00 mSv from 2004 to 2008 is also presented. The number of registered thorax monthly dose higher than 4.0 mSv is increasing, as its value. In this period the highest dose measured reaches 56.9 mSv, in one month, in 2008. About 50% of the annual doses are smaller than the monthly record level of 0.20 mSv. In 2005, around 100 professionals of RJ NMS received annual doses higher than 4.0 mSv, considering only external doses, but no one receives doses higher than 20.0 mSv. Extremities dosimeters are used by about 15% of the staff. In some cases, these doses are more than 10 times higher than the dose in thorax. This study shows the importance to improve radiation protection procedures in NM. (author)

  4. Primary experiment aimed at selecting the suitable dose to mutation induction in two soybean cultivars

    International Nuclear Information System (INIS)

    Nabulsi, I.; Mir Ali, N

    1991-07-01

    Seeds from two soybean [Glycine Max L. (Merrill)] cultivars K-25 and K-38 were irradiated with the following doses of gamma rays: 100, 150, 200, 250, 300, 350, 400 and 500 Gy. The dose rate was 9.25 Gy/minute. A week after irradiation 25 seeds were sown from each variety in pots (26.5 x 26.5 cm) with 4 replicates in a randomized complete block design under greenhouse conditions. The distance between the cotyledon and the first leaf was measured 4 weeks after sowing and the results showed stimualtion effect in the 100 and 150 Gy doses in comparison to the control whereas in the higher doses, a gradual reduction was realized in addition to the appearance of the necrotic spots on the leaves which was increased in percentages along with the dose. The results indicated that doses between 100 and 200 Gy achieved the highest rate of mutations with minimal rate of lethality hence achieving the aim of this preliminary experiment. (author). 5 refs., 2 tabs., 2 figs

  5. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yoshida, Ken; Mitomo, Masanori; Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji; Yoshida, Mineo

    2002-01-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients) for OAR were lower

  6. Equivalent dose determination in foraminifera: analytical description of the CO2--signal dose-response curve

    International Nuclear Information System (INIS)

    Hoffmann, D.; Woda, C.; Mangini, A.

    2003-01-01

    The dose-response of the CO 2 - signal (g=2.0006) in foraminifera with ages between 19 and 300 ka is investigated. The sum of two exponential saturation functions is an adequate function to describe the dose-response curve up to an additional dose of 8000 Gy. It yields excellent dating results but requires an artificial doses of at least 5000 Gy. For small additional doses of about 500 Gy the single exponential saturation function can be used to calculate a reliable equivalent dose D E , although it does not describ the dose-response for higher doses. The CO 2 - -signal dose-response indicates that the signal has two components of which one is less stable than the other

  7. Peripheral doses from pediatric IMRT

    International Nuclear Information System (INIS)

    Klein, Eric E.; Maserang, Beth; Wood, Roy; Mansur, David

    2006-01-01

    Peripheral dose (PD) data exist for conventional fields (≥10 cm) and intensity-modulated radiotherapy (IMRT) delivery to standard adult-sized phantoms. Pediatric peripheral dose reports are limited to conventional therapy and are model based. Our goal was to ascertain whether data acquired from full phantom studies and/or pediatric models, with IMRT treatment times, could predict Organ at Risk (OAR) dose for pediatric IMRT. As monitor units (MUs) are greater for IMRT, it is expected IMRT PD will be higher; potentially compounded by decreased patient size (absorption). Baseline slab phantom peripheral dose measurements were conducted for very small field sizes (from 2 to 10 cm). Data were collected at distances ranging from 5 to 72 cm away from the field edges. Collimation was either with the collimating jaws or the multileaf collimator (MLC) oriented either perpendicular or along the peripheral dose measurement plane. For the clinical tests, five patients with intracranial or base of skull lesions were chosen. IMRT and conventional three-dimensional (3D) plans for the same patient/target/dose (180 cGy), were optimized without limitation to the number of fields or wedge use. Six MV, 120-leaf MLC Varian axial beams were used. A phantom mimicking a 3-year-old was configured per Center for Disease Control data. Micro (0.125 cc) and cylindrical (0.6 cc) ionization chambers were appropriated for the thyroid, breast, ovaries, and testes. The PD was recorded by electrometers set to the 10 -10 scale. Each system set was uniquely calibrated. For the slab phantom studies, close peripheral points were found to have a higher dose for low energy and larger field size and when MLC was not deployed. For points more distant from the field edge, the PD was higher for high-energy beams. MLC orientation was found to be inconsequential for the small fields tested. The thyroid dose was lower for IMRT delivery than that predicted for conventional (ratio of IMRT/cnventional ranged from

  8. Gamma Radiation Doses In Sweden

    International Nuclear Information System (INIS)

    Almgren, Sara; Isaksson, Mats; Barregaard, Lars

    2008-01-01

    Gamma dose rate measurements were performed in one urban and one rural area using thermoluminescence dosimeters (TLD) worn by 46 participants and placed in their dwellings. The personal effective dose rates were 0.096±0.019(1 SD) and 0.092±0.016(1 SD)μSv/h in the urban and rural area, respectively. The corresponding dose rates in the dwellings were 0.11±0.042(1 SD) and 0.091±0.026(1 SD)μSv/h. However, the differences between the areas were not significant. The values were higher in buildings made of concrete than of wood and higher in apartments than in detached houses. Also, 222 Rn measurements were performed in each dwelling, which showed no correlation with the gamma dose rates in the dwellings

  9. Form factors and complete spectrum of XXX antiperiodic higher spin chains by quantum separation of variables

    Energy Technology Data Exchange (ETDEWEB)

    Niccoli, G. [YITP, Stony Brook University, New York 11794-3840 (United States)

    2013-05-15

    The antiperiodic transfer matrices associated to higher spin representations of the rational 6-vertex Yang-Baxter algebra are analyzed by generalizing the approach introduced recently in the framework of Sklyanin's quantum separation of variables (SOV) for cyclic representations, spin-1/2 highest weight representations, and also for spin-1/2 representations of the 6-vertex reflection algebra. Such SOV approach allow us to derive exactly results which represent complicate tasks for more traditional methods based on Bethe ansatz and Baxter Q-operator. In particular, we both prove the completeness of the SOV characterization of the transfer matrix spectrum and its simplicity. Then, the derived characterization of local operators by Sklyanin's quantum separate variables and the expression of the scalar products of separate states by determinant formulae allow us to compute the form factors of the local spin operators by one determinant formulae similar to those of the scalar products.

  10. Dose-response relationship in locoregional control for patients with stage II-III esophageal cancer treated with concurrent chemotherapy and radiotherapy

    International Nuclear Information System (INIS)

    Zhang Zhen; Liao Zhongxing; Jin Jing; Ajani, Jaffer; Chang, Joe Y.; Jeter, Melenda; Guerrero, Thomas; Stevens, Craig W.; Swisher, Stephen; Ho, Linus; Yao, James; Allen, Pamela; Cox, James D.; Komaki, Ritsuko

    2005-01-01

    Purpose: To evaluate the correlation between radiation dose and locoregional control (LRC) for patients with Stage II-III unresectable esophageal cancer treated with concurrent chemotherapy and radiotherapy. Methods and materials: The medical records of 69 consecutive patients with clinical Stage II or III esophageal cancer treated with definitive chemoradiotherapy at the University of Texas M. D. Anderson Cancer Center between 1990 and 1998 were retrospectively reviewed. Of the 69 patients, 43 had received ≤51 Gy (lower dose group) and 26 >51 Gy (higher dose group). The median dose in the lower and higher dose groups was 30 Gy (range, 30-51 Gy) and 59.4 Gy (range, 54-64.8 Gy), respectively. Two fractionation schedules were used: rapid fractionation, delivering 30 Gy at 3 Gy/fraction within 2 weeks, and standard fractionation, delivering ≥45 Gy at 1.8-2 Gy/fraction daily. Total doses of 5% (46.2% vs. 23.3%). The lower dose group had more N1 tumors, but the tumor classification and stage grouping were similar in the two groups. The median follow-up time for all patients was 22 months (range, 2-56 months). Patients in the higher dose group had a statistically significant better 3-year local control rate (36% vs. 19%, p = 0.011), disease-free survival rate (25% vs. 10%, p = 0.004), and overall survival rate (13% vs. 3%, p = 0.054). A trend toward a better distant-metastasis-free survival rate was noted in the higher dose group (72% vs. 59%, p = 0.12). The complete clinical response rate was significantly greater in the higher dose group (46% vs. 23%, p = 0.048). In both groups, the most common type of first failure was persistence of the primary tumor. Significantly fewer patients in the higher dose group had tumor persistence after treatment (p = 0.02). No statistically significant difference was found between the two groups in the pattern of locoregional or distant failure. The long-term side effects of chemoradiotherapy were similar in the two groups, although

  11. Low doses of six toxicants change plant size distribution in dense populations of Lactuca sativa.

    Science.gov (United States)

    Belz, Regina G; Patama, Marjo; Sinkkonen, Aki

    2018-08-01

    Toxicants are known to have negligible or stimulatory, i.e. hormetic, effects at low doses below those that decrease the mean response of a plant population. Our earlier observations indicated that at such low toxicant doses the growth of very fast- and slow-growing seedlings is selectively altered, even if the population mean remains constant. Currently, it is not known how common these selective low-dose effects are, whether they are similar among fast- and slow-growing seedlings, and whether they occur concurrently with hormetic effects. We tested the response of Lactuca sativa in complete dose-response experiments to six different toxicants at doses that did not decrease population mean and beyond. The tested toxicants were IAA, parthenin, HHCB, 4-tert-octylphenol, glyphosate, and pelargonic acid. Each experiment consisted of 14,400-16,800 seedlings, 12-14 concentrations, 24 replicates per concentration and 50 germinated seeds per replicate. We analyzed the commonness of selective low-dose effects and explored if toxic effects and hormetic stimulation among fast- and slow-growing individuals occurred at the same concentrations as they occur at the population level. Irrespective of the observed response pattern and toxicant, selective low-dose effects were found. Toxin effects among fast-growing individuals usually started at higher doses compared to the population mean, while the opposite was found among slow-growing individuals. Very low toxin exposures tended to homogenize plant populations due to selective effects, while higher, but still hormetic doses tended to heterogenize plant populations. Although the extent of observed size segregation varied with the specific toxin tested, we conclude that a dose-dependent alteration in size distribution of a plant population may generally apply for many toxin exposures. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Optimization of image quality and patient dose in mammography

    International Nuclear Information System (INIS)

    Shafqat Faaruq; Jaferi, R.A.; Nafeesa Nazlee

    2007-01-01

    Complete test of publication follows. Optimization of patient dose and image quality can be defined as to get the best image quality with minimum possible radiation dose to the patient by setting various parameters and modes of operation available in mammography machines. The optimization procedures were performed on two mammography units from M/S GE and Metaltronica, available at NORI, using standard mammographic accreditation phantom (Model: BR-156) and acrylic sheets of variable thicknesses. Quality assurance and quality control (QC) tests being the essential part of optimization. The QC tests as recommended by American College of Radiology, were first performed on both machines as well as X-ray film processor. In the second step, different affecting the image quality and radiation dose to patient, like film screen combination (FSC), phantom optical density (PD), kVp, mAs etc, were adjusted for various phantom thicknesses ranging from 3 cm to 6.5 cm in various modes of operation in the machines (semi-auto- and manual in GE, Auto-, semi-auto- and manual mode in Metaltronica). The image quality was studied for these optimized parameters on the basis of the number of test objects of the phantom visible in these images. Finally the linear relationship between mAs and skin entrance dose (mGy) was verified using ionization chamber with the phantom and the actual patients. Despite some practical limitations, the results of the quality assurance tests were within acceptable limits defined by ACR. The dose factor for GE was 68.0 y/mAs, while 76.0 mGy/mAs for Metaltronica at 25 kVp. Before the start of this study the only one mammography unit GE, was routinely used at NORI and normal mode of operation of this unit was semi-auto mode with fixed kVp independent of compressed breast thickness, but in this study it was concluded that selecting kVp according to beast thickness result in an appreciable dose reduction (4-5 times less) without any compromise in image quality. The

  13. Patient dose measurement and dose reduction in chest radiography

    Directory of Open Access Journals (Sweden)

    Milatović Aleksandra A.

    2014-01-01

    Full Text Available Investigations presented in this paper represent the first estimation of patient doses in chest radiography in Montenegro. In the initial stage of our study, we measured the entrance surface air kerma and kerma area product for chest radiography in five major health institutions in the country. A total of 214 patients were observed. We reported the mean value, minimum and third quartile values, as well as maximum values of surface air kerma and kerma area product of patient doses. In the second stage, the possibilities for dose reduction were investigated. Mean kerma area product values were 0.8 ± 0.5 Gycm2 for the posterior-anterior projection and 1.6 ± 0.9 Gycm2 for the lateral projection. The max/min ratio for the entrance surface air kerma was found to be 53 for the posterior-anterior projection and 88 for the lateral projection. Comparing the results obtained in Montenegro with results from other countries, we concluded that patient doses in our medical centres are significantly higher. Changes in exposure parameters and increased filtration contributed to a dose reduction of up to 36% for posterior-anterior chest examinations. The variability of the estimated dose values points to a significant space for dose reduction throughout the process of radiological practice optimisation.

  14. Assessment of ocular beta radiation dose distribution due to 106Ru/106Rh brachytherapy applicators using MCNPX Monte Carlo code

    Directory of Open Access Journals (Sweden)

    Nilseia Aparecida Barbosa

    2014-08-01

    Full Text Available Purpose: Melanoma at the choroid region is the most common primary cancer that affects the eye in adult patients. Concave ophthalmic applicators with 106Ru/106Rh beta sources are the more used for treatment of these eye lesions, mainly lesions with small and medium dimensions. The available treatment planning system for 106Ru applicators is based on dose distributions on a homogeneous water sphere eye model, resulting in a lack of data in the literature of dose distributions in the eye radiosensitive structures, information that may be crucial to improve the treatment planning process, aiming the maintenance of visual acuity. Methods: The Monte Carlo code MCNPX was used to calculate the dose distribution in a complete mathematical model of the human eye containing a choroid melanoma; considering the eye actual dimensions and its various component structures, due to an ophthalmic brachytherapy treatment, using 106Ru/106Rh beta-ray sources. Two possibilities were analyzed; a simple water eye and a heterogeneous eye considering all its structures. Two concave applicators, CCA and CCB manufactured by BEBIG and a complete mathematical model of the human eye were modeled using the MCNPX code. Results and Conclusion: For both eye models, namely water model and heterogeneous model, mean dose values simulated for the same eye regions are, in general, very similar, excepting for regions very distant from the applicator, where mean dose values are very low, uncertainties are higher and relative differences may reach 20.4%. For the tumor base and the eye structures closest to the applicator, such as sclera, choroid and retina, the maximum difference observed was 4%, presenting the heterogeneous model higher mean dose values. For the other eye regions, the higher doses were obtained when the homogeneous water eye model is taken into consideration. Mean dose distributions determined for the homogeneous water eye model are similar to those obtained for the

  15. Combination chemotherapy concurrent with small dose radiation therapy for small cell carcinoma of the lung

    International Nuclear Information System (INIS)

    Tada, Toshihiko; Fujita, Hiroji; Shintomi, Takenori

    1987-01-01

    Forty consecutive patients with small cell carcinoma of the lung were treated with chemotherapy, radiotherapy or both. Of 34 patients treated with chemotherapy, 24 were treated with combination chemotherapy, containing cyclophosphamide vincristine methotrexate and procarbazine, concurrent with small dose radiation therapy (500 cGy/5 fraction) as a chemosensitizer (COMPrt). The response rate to this regimen was 81 % (29 % complete) and the 2 year survival rate was 28.6 %. These results have been superior to other regimens and the toxicity was not see to be any higher. After completion of COMPrt regimen, 10 patients were treated with intrathoracic radiation therapy (average dose 3000 cGy) and 3 recieved surgical treatment. Radiation therapy improved the 2-year survival rate (42.2 %) when compared with those patients who received no radiation therapy (18.2 %). Three patients received surgical treatment were considered to be disease-free for 23, 17, and 9 months respectively, after induction of chemotherapy. (author)

  16. Real time dose rate measurements with fiber optic probes based on the RL and OSL of beryllium oxide

    International Nuclear Information System (INIS)

    Teichmann, T.; Sponner, J.; Jakobi, Ch.; Henniger, J.

    2016-01-01

    This work covers the examination of fiber optical probes based on the radioluminescence and real time optically stimulated luminescence of beryllium oxide. Experiments are carried out to determine the fundamental dosimetric and temporal properties of the system and evaluate its suitability for dose rate measurements in brachytherapy and other applications using non-pulsed radiation fields. For this purpose the responses of the radioluminescence and optically stimulated luminescence signal have been investigated in the dose rate range of 20 mGy/h to 3.6 Gy/h and for doses of 1 mGy up to 6 Gy. Furthermore, a new, efficient analysis procedure, the double phase reference summing, is introduced, leading to a real time optically stimulated luminescence signal. This method allows a complete compensation of the stem effect during the measurement. In contrast to previous works, the stimulation of the 1 mm cylindrical beryllium oxide detectors is performed with a symmetric function during irradiation. The investigated dose rates range from 0.3 to 3.6 Gy/h. The real time optically stimulated luminescence signal of beryllium oxide shows a dependency on both the dose rate and the applied dose. To overcome the problem of dose dependency, further experiments using higher stimulation intensities have to follow. - Highlights: • RL and OSL measurements with BeO extended to low dose (rate) range. • A new method to obtain the real time OSL: Dual Phase Reference Summing. • Real time OSL signal shows both dose and dose rate dependency. • Real time OSL enables a complete discrimination of the stem effect.

  17. Higher than standard radiation doses (≥72 Gy) with or without androgen deprivation in the treatment of localized prostate cancer

    International Nuclear Information System (INIS)

    Kupelian, Patrick A.; Mohan, Dasarahally S.; Lyons, Janice; Klein, Eric A.; Reddy, Chandana A.

    2000-01-01

    ), iPSA (continuous variable), bGS (≤6 vs. ≥7), use of AD (yes vs. no), radiation technique (conformal versus standard), and radiation dose (continuous variable). T-stage (p < 0.001), iPSA (p < 0.001), bGS (p < 0.001), and RT dose (p < 0.001) were independent predictors of outcome. Age (p = 0.74), race (p = 0.96), radiation technique (p = 0.15), and use of AD (p = 0.31) were not. We observed 11% clinical failures (local, distant, or both) at 5 years and 15% at 8 years for the entire cohort. There was a statistically significant improvement with higher radiation doses (p 0.032). The 5-year clinical relapse rates for patients receiving ≥72 Gy versus <72 Gy were 5% and 12%, respectively. The 8-year clinical relapse rates for patients receiving radiation doses ≥72 Gy versus <72 Gy were 5% and 17%, respectively (p = 0.026). Conclusion: Patients receiving radiation doses exceeding 72 Gy had significantly better bRFS and clinical disease-free survival rates. Although results need to be confirmed with longer follow-up, these preliminary results are extremely encouraging. If these results are confirmed by other institutions and by longer follow-up, RT doses exceeding 72 Gy should be considered as standard of care

  18. SU-F-I-38: Patient Organ Specific Dose Assessment in Coronary CT Angiograph Using Voxellaized Volume Dose Index in Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Fallal, Mohammadi Gh.; Riyahi, Alam N.; Graily, Gh. [Tehran University of Medical Scienced(TUMS), School of Medicine, Department of Nedical Physics and Biomedical Engineering, Tehran (Iran, Islamic Republic of); Paydar, R. [Iran University of Medical Sciences(IUMS), Allied Medicine Faculty, Department of radiation Sciences, Tehran (Iran, Islamic Republic of)

    2016-06-15

    Purpose: Clinical use of multi detector computed tomography(MDCT) in diagnosis of diseases due to high speed in data acquisition and high spatial resolution is significantly increased. Regarding to the high radiation dose in CT and necessity of patient specific radiation risk assessment, the adoption of new method in the calculation of organ dose is completely required and necessary. In this study by introducing a conversion factor, patient organ dose in thorax region based on CT image data using MC system was calculated. Methods: The geometry of x-ray tube, inherent filter, bow tie filter and collimator were designed using EGSnrc/BEAMnrc MC-system component modules according to GE-Light-speed 64-slices CT-scanner geometry. CT-scan image of patient thorax as a specific phantom was voxellised with 6.25mm3 in voxel and 64×64×20 matrix size. Dose to thorax organ include esophagus, lung, heart, breast, ribs, muscle, spine, spinal cord with imaging technical condition of prospectively-gated-coronary CT-Angiography(PGT) as a step and shoot method, were calculated. Irradiation of patient specific phantom was performed using a dedicated MC-code as DOSXYZnrc with PGT-irradiation model. The ratio of organ dose value calculated in MC-method to the volume CT dose index(CTDIvol) reported by CT-scanner machine according to PGT radiation technique has been introduced as conversion factor. Results: In PGT method, CTDIvol was 10.6mGy and Organ Dose/CTDIvol conversion factor for esophagus, lung, heart, breast, ribs, muscle, spine and spinal cord were obtained as; 0.96, 1.46, 1.2, 3.28. 6.68. 1.35, 3.41 and 0.93 respectively. Conclusion: The results showed while, underestimation of patient dose was found in dose calculation based on CTDIvol, also dose to breast is higher than the other studies. Therefore, the method in this study can be used to provide the actual patient organ dose in CT imaging based on CTDIvol in order to calculation of real effective dose(ED) based on organ dose

  19. The patient dose survey and dose reduction in diagnostic radiology

    International Nuclear Information System (INIS)

    Dang Thanh Luong; Duong Van Vinh; Ha Ngoc Thach

    2000-01-01

    This paper presented the results of the patient dose survey in some hospitals in Hanoi from 1995 to 1997. The main investigated types of the X-ray examination were: Chest PA, LAT; Skull PA/AP, LAT; Lumbar spine AP, LAT; and Pelvis AP. The fluctuation of the entrance surface doses (ESD) was too large, even in the same type of X-ray examination and X-ray facility. It was found that the ratio of maximum and minimum ESD were ranged from 1.5 to 18. The mean values of ESD for chest and skull were higher than CEC recommended values, while the mean values of lumbar spine and pelvis were smaller than that of CEC recommended values. The result of dose intercomparison was also reported. Some methods of dose reduction were applied for improving the patient dose in X-ray departments such as a high kV technique, high sensitive screen-film combination. (author)

  20. Dose dependence of complication rates in cervix cancer radiotherapy

    International Nuclear Information System (INIS)

    Orton, C.G.; Wolf-Rosenblum, S.

    1986-01-01

    The population selected for this study was a group of 410 Stage IIB and III squamous cell Ca cervix patients treated at the Radiumhemmet between the years 1958-1966. A total of 48 of these patients developed moderate-to-severe rectal and/or bladder complications. Of these, 33 were evaluable with respect to dose-dependence of complications, that is, complete intracavitary dose measurements and external beam dose calculations, no chemotherapy or electrocautery, and complete clinical radiotherapy records. A group of 57 randomly selected uninjured patients were used as controls. Results show good correlation between dose, expressed in TDF units, and complication rates for both rectal and bladder injuries. Severity of rectal injury was observed to increase with increase in dose, although no such correlation was observed for bladder injuries. Mean delays in the expression of symptoms of injury were 10 months for the rectum and 22 months for the bladder

  1. Dose dependence of complication rates in cervix cancer radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Orton, C.G.; Wolf-Rosenblum, S.

    1986-01-01

    The population selected for this study was a group of 410 Stage IIB and III squamous cell Ca cervix patients treated at the Radiumhemmet between the years 1958-1966. A total of 48 of these patients developed moderate-to-severe rectal and/or bladder complications. Of these, 33 were evaluable with respect to dose-dependence of complications, that is, complete intracavitary dose measurements and external beam dose calculations, no chemotherapy or electrocautery, and complete clinical radiotherapy records. A group of 57 randomly selected uninjured patients were used as controls. Results show good correlation between dose, expressed in TDF units, and complication rates for both rectal and bladder injuries. Severity of rectal injury was observed to increase with increase in dose, although no such correlation was observed for bladder injuries. Mean delays in the expression of symptoms of injury were 10 months for the rectum and 22 months for the bladder.

  2. Comparison of dose length, area, and volume histograms as quantifiers of urethral dose in prostate brachytherapy

    International Nuclear Information System (INIS)

    Butler, Wayne M.; Merrick, Gregory S.; Dorsey, Anthony T.; Hagedorn, Brenda M.

    2000-01-01

    Purpose: To determine the magnitude of the differences between urethral dose-volume, dose-area, and dose-length histograms (DVH, DAH, and DLH, respectively, or DgH generically). Methods and Materials: Six consecutive iodine-125 ( 125 I) patients and 6 consecutive palladium-103 ( 103 Pd) patients implanted via a modified uniform planning approach were evaluated with day 0 computed tomography (CT)-based dosimetry. The urethra was identified by the presence of a urinary catheter and was hand drawn on the CT images with a mean radius of 3.3 ± 0.7 mm. A 0.1-mm calculation matrix was employed for the urethral volume and surface analysis, and urethral dose points were placed at the centroid of the urethra on each 5-mm CT slice. Results: Although individual patient DLHs were step-like, due to the sparseness of the data points, the composite urethral DLH, DAH, and DVHs were qualitatively similar. The DAH curve delivered more radiation than the other two curves at all doses greater than 90% of the prescribed minimum peripheral dose (mPD) to the prostate. In addition, the DVH curve was consistently higher than the DLH curve at most points throughout that range. Differences between the DgH curves were analyzed by integrating the difference curves between 0 and 200% of the mPD. The area-length, area-volume, and volume-length difference curves integrated in the ratio of 3:2:1. The differences were most pronounced near the inflection point of the DgH curves with mean A 125 , V 125 , and L 125 values of 36.6%, 31.4%, and 23.0%, respectively, of the urethra. Quantifiers of urethral hot spots such as D 10 , defined as the minimal dose delivered to the hottest 10% of the urethra, followed the same ranking: area analysis indicated the highest dose and length analysis, the lowest dose. D 10 was 148% and 136% of mPD for area and length evaluations, respectively. Comparing the two isotopes in terms of the amount of urethra receiving a given dose, 103 Pd implants were significantly

  3. Case Example of Dose Optimization Using Data From Bortezomib Dose-Finding Clinical Trials.

    Science.gov (United States)

    Lee, Shing M; Backenroth, Daniel; Cheung, Ying Kuen Ken; Hershman, Dawn L; Vulih, Diana; Anderson, Barry; Ivy, Percy; Minasian, Lori

    2016-04-20

    The current dose-finding methodology for estimating the maximum tolerated dose of investigational anticancer agents is based on the cytotoxic chemotherapy paradigm. Molecularly targeted agents (MTAs) have different toxicity profiles, which may lead to more long-lasting mild or moderate toxicities as well as to late-onset and cumulative toxicities. Several approved MTAs have been poorly tolerated during long-term administration, leading to postmarketing dose optimization studies to re-evaluate the optimal treatment dose. Using data from completed bortezomib dose-finding trials, we explore its toxicity profile, optimize its dose, and examine the appropriateness of current designs for identifying an optimal dose. We classified the toxicities captured from 481 patients in 14 bortezomib dose-finding studies conducted through the National Cancer Institute Cancer Therapy Evaluation Program, computed the incidence of late-onset toxicities, and compared the incidence of dose-limiting toxicities (DLTs) among groups of patients receiving different doses of bortezomib. A total of 13,008 toxicities were captured: 46% of patients' first DLTs and 88% of dose reductions or discontinuations of treatment because of toxicity were observed after the first cycle. Moreover, for the approved dose of 1.3 mg/m(2), the estimated cumulative incidence of DLT was > 50%, and the estimated cumulative incidence of dose reduction or treatment discontinuation because of toxicity was nearly 40%. When considering the entire course of treatment, the approved bortezomib dose exceeds the conventional ceiling DLT rate of 20% to 33%. Retrospective analysis of trial data provides an opportunity for dose optimization of MTAs. Future dose-finding studies of MTAs should take into account late-onset toxicities to ensure that a tolerable dose is identified for future efficacy and comparative trials. © 2016 by American Society of Clinical Oncology.

  4. Lutein bioavailability is higher from lutein-enriched eggs than from supplements and spinach in men.

    Science.gov (United States)

    Chung, Hae-Yun; Rasmussen, Helen M; Johnson, Elizabeth J

    2004-08-01

    Lutein may be protective against diseases such as age-related macular degeneration (ARMD). At present, data regarding bioavailability of lutein from various sources are insufficient. Healthy men (n = 10) participated in an intervention study with a crossover design. After a 2-wk washout period during which they consumed a low-carotenoid diet, the men were administered 1 of 4 lutein doses (lutein supplement, lutein ester supplement, spinach, and lutein-enriched egg) for 9 d. All lutein doses provided 6 mg lutein except for the lutein ester dose, which provided 5.5 mg lutein equivalents. Serum samples were collected from fasting subjects on d -14, 1 (baseline), 2, 3, and 10 and analyzed for changes in lutein concentration. Triacylglycerol-rich lipoproteins (TRL) were separated from postprandial blood samples (0-24 h) after the first lutein dose and analyzed for lutein concentration. Subjects completed all 4 treatments of the study in random order. Results from repeated-measures 1-way ANOVA showed that the baseline and dose-adjusted lutein response in serum was significantly higher after egg consumption than after lutein, lutein ester, and spinach consumption on d 10. There was no significant difference in TRL response. In conclusion, the lutein bioavailability from egg is higher than that from other sources such as lutein, lutein ester supplements, and spinach. The lutein bioavailability from lutein, lutein ester supplements, and spinach did not differ. This finding may have implications for dietary recommendations that may decrease the risk of certain diseases, e.g., ARMD.

  5. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer.

    Science.gov (United States)

    Martinez, Alvaro A; Gustafson, Gary; Gonzalez, José; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-06-01

    To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level >or=10.0 ng/mL, Gleason score >or=7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause-specific survival with higher doses. These results, coupled with the low risk of complications, the advantage of not being radioactive after implantation, and the real-time interactive planning, define a new standard for treatment.

  6. Estimation of doses from radioactively contaminated disaster wastes reused for pavements

    International Nuclear Information System (INIS)

    Sawaguchi, Takuma; Takeda, Seiji; Kimura, Hideo; Tanaka, Tadao

    2015-01-01

    It is desirable that the disaster wastes contaminated by radioactive cesium after the severe accident at the Fukushima Nuclear Plant are reused as much as possible in order to minimize the quantity to be disposed of. Ministry of the Environment showed the policy that the wastes containing cesium of higher concentration than the clearance level (100 Bq/kg) were reusable as materials of construction such as subbase course materials of pavements under controlled condition with measures to lower exposure doses. In this study, in order to provide technical information for making a guideline on the use of contaminated concrete materials recycled from disaster wastes as pavement, doses for workers and the public were estimated, and the reusable concentration of radioactive cesium in the wastes was evaluated. It was shown that the external exposure of the public (children) residing near the completed pavement gave the minimum radiocesium concentration in order to comply with the dose criteria. The recycled concrete materials whose average concentration of cesium lower than 2,700 Bq/kg can be used as the subbase course materials of pavements. (author)

  7. Risk of low-doses in radiodiagnosis; Risque des faibles doses en radiodiagnostic. Mythes, reglementation et rationalite

    Energy Technology Data Exchange (ETDEWEB)

    Cordoliani, Y.S.; Sarrazin, J.L.; Le Frian, G.; Soulie, D.; Leveque, C. [Hopital d`Instruction des Armees du Val-de-Grace, 75 - Paris (France)

    1997-12-31

    The effect of low doses of X-rays is inferred from the indubitable effects of high doses in human carcinogenesis, Genetic and teratogenic effects are mainly inferred from animal experimentation because clinical surveys of irradiated pregnant women have failed to demonstrate such consequences in the children, except for mental retardation after Japanese atomic bombing. Since no evidence of carcinogenic effect has been produced by epidemiological studies for doses lower than 500 mSv. the estimation of the risk due to low doses has been extrapolated from the linear relation between dose and cancers at high doses. Such an extrapolation gives a maximal risk which is falsely used as a probability of cancer. The actual risk lies between zero and this maximal number, and many epidemiologic surveys in people receiving doses much higher than the mean level of background irradiation failed to demonstrate higher rate of cancer. The explanation of this fact, which is supported by the most recent biological data, is the efficacy of the DNA repair system at low level of exposure to ionizing radiations. We expose the principles of regulation of radioprotection for workers, and give estimations of the doses delivered to the patients and the personnel by diagnostic investigations, by comparing these doses with those of natural irradiation. Practical aspect for conventional and computed radiology are exposed for patients and workers. (authors)

  8. High-Dose Atomoxetine Treatment of ADHD in Youths with Limited Response to Standard Doses

    Science.gov (United States)

    Kratochvil, Christopher J.; Michelson, David; Newcorn, Jeffrey H.; Weiss, Margaret D.; Busner, Joan; Moore, Rodney J.; Ruff, Dustin D.; Ramsey, Janet; Dickson, Ruth; Turgay, Atilla; Saylor, Keith E.; Luber, Stephen; Vaughan, Brigette; Allen, Albert J.

    2007-01-01

    Objective: To assess the utility and tolerability of higher than standard atomoxetine doses to treat attention-deficit/hyperactivity disorder (ADHD). Method: Two randomized, double-blind trials of atomoxetine nonresponders ages 6 to 16 years were conducted comparing continued treatment with same-dose atomoxetine to treatment using greater than…

  9. Doses from portable gauges

    International Nuclear Information System (INIS)

    Linauskas, S.H.

    1988-08-01

    Field studies to measure actual radiation exposures of operators of commercial moisture-density gauges were undertaken in several regions of Canada. Newly developed bubble detector dosimeter technology and conventional dosimetry such as thermoluminescent dosimeters (TLDs), integrating electronic dosimeters (DRDs), and CR-39 neutron track-etch detectors were used to estimate the doses received by 23 moisture-density gauge operators and maintenance staff. These radiation dose estimates were supported by mapping radiation fields and accounting for the time an operator was near a gauge. Major findings indicate that gauge maintenance and servicing workers were more likely than gauge operators to receive exposures above the level of 5 mSv, and that neutron doses were roughly the same as gamma doses. Gauge operators receive approximately 75% of their dose when transporting and carrying the gauge. Dose to their hands is similar to the dose to their trunks, but the dose to their feet area is 6 to 30 times higher. Gamma radiation is the primary source of radiation contributing to operator dose

  10. Dose rate effect on low-dose hyper-radiosensitivity with cells in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Geon-Min; Kim, Eun-Hee [Seoul National University, Seoul (Korea, Republic of)

    2016-10-15

    Low-dose hyper-radiosensitivity (HRS) is the phenomenon that mammalian cells exhibit higher sensitivity to radiation at low doses (< 0.5 Gy) than expected by the linear-quadratic model. At doses above 0.5Gy, the cellular response is recovered to the level expected by the linear-quadratic model. This transition is called the increased radio-resistance (IRR). HRS was first verified using Chinese hamster V79 cells in vitro by Marples and has been confirmed in studies with other cell lines including human normal and tumor cells. HRS is known to be induced by inactivation of ataxia telangiectasia-mutated (ATM), which plays a key role in repairing DNA damages. Considering the connection between ATM and HRS, one can infer that dose rate may affect cellular response regarding HRS at low doses. In this study, we quantitated the effect of dose rate on HRS by clonogenic assay with normal and tumor cells. The HRS of cells at low dose exposures is a phenomenon already known. In this study, we observed HRS of rat normal diencephalon cells and rat gliosarcoma cells at doses below 1 Gy. In addition, we found that dose rate mattered. HRS occurred at low doses, but only when total dose was delivered at a rate below certain level.

  11. Evaluation of patient dose in imaging using a cone-beam CT dosimetry by X-ray films for radiotherapeutic dose

    International Nuclear Information System (INIS)

    Yoshida, Yuri; Morita, Yasuhiko; Honda, Eiichi; Tomotake, Yoritoki; Ichikawa, Tetsuo

    2008-01-01

    A limited cone-beam X-ray CT (3DX multi-image micro CT; 3DX-FPD) is widely used in dentistry because it provides a lower cost, smaller size, and higher spatial resolution than a CT for medicine. Our recent research suggested that the patient dose of 3DX-FPD was less than 7/10 of that of CT, and it was several to 10 times more than that of dental or panoramic radiography. The purpose of this study was to evaluate the spatial dose distribution from 3DX-FPD and to estimate the influence of dose by positioning of the region of interest. Dosimetry of the organs and the tissues was performed using an anthropomorphic Alderson Rando phantom and X-ray films for measurement of radiotherapeutic dose. Measurements of dose distribution were performed using a cylinder-type tank of water made of acrylic resin imitating the head and X-ray films. The results are summarized as follows: The dose was higher as the ratio of the air region included in the region of interest increased. The dose distribution was not homogeneous and the dose was highest in the skin region. The dose was higher for several seconds after the beginning of exposure. It was concluded that patient positioning, as well as exposure conditions including the size of the exposure field and tube current, could greatly influence the patient dose in 3DX-FPD. In addition, it is necessary to consider the influence of image quality for the treatment of dental implants. (author)

  12. Radiation dose in vertebroplasty

    International Nuclear Information System (INIS)

    Mehdizade, A.; Lovblad, K.O.; Wilhelm, K.E.; Somon, T.; Wetzel, S.G.; Kelekis, A.D.; Yilmaz, H.; Abdo, G.; Martin, J.B.; Viera, J.M.; Ruefenacht, D.A.

    2004-01-01

    We wished to measure the absorbed radiation dose during fluoroscopically controlled vertebroplasty and to assess the possibility of deterministic radiation effects to the operator. The dose was measured in 11 consecutive procedures using thermoluminescent ring dosimeters on the hand of the operator and electronic dosimeters inside and outside of the operator's lead apron. We found doses of 0.022-3.256 mGy outside and 0.01-0.47 mGy inside the lead apron. Doses on the hand were higher, 0.5-8.5 mGy. This preliminary study indicates greater exposure to the operator's hands than expected from traditional apron measurements. (orig.)

  13. Microfluidic thrombosis under multiple shear rates and antiplatelet therapy doses.

    Directory of Open Access Journals (Sweden)

    Melissa Li

    Full Text Available The mainstay of treatment for thrombosis, the formation of occlusive platelet aggregates that often lead to heart attack and stroke, is antiplatelet therapy. Antiplatelet therapy dosing and resistance are poorly understood, leading to potential incorrect and ineffective dosing. Shear rate is also suspected to play a major role in thrombosis, but instrumentation to measure its influence has been limited by flow conditions, agonist use, and non-systematic and/or non-quantitative studies. In this work we measured occlusion times and thrombus detachment for a range of initial shear rates (500, 1500, 4000, and 10000 s(-1 and therapy concentrations (0-2.4 µM for eptifibatide, 0-2 mM for acetyl-salicylic acid (ASA, 3.5-40 Units/L for heparin using a microfluidic device. We also measured complete blood counts (CBC and platelet activity using whole blood impedance aggregometry. Effects of shear rate and dose were analyzed using general linear models, logistic regressions, and Cox proportional hazards models. Shear rates have significant effects on thrombosis/dose-response curves for all tested therapies. ASA has little effect on high shear occlusion times, even at very high doses (up to 20 times the recommended dose. Under ASA therapy, thrombi formed at high shear rates were 4 times more prone to detachment compared to those formed under control conditions. Eptifibatide reduced occlusion when controlling for shear rate and its efficacy increased with dose concentration. In contrast, the hazard of occlusion from ASA was several orders of magnitude higher than that of eptifibatide. Our results show similar dose efficacy to our low shear measurements using whole blood aggregometry. This quantitative and statistically validated study of the effects of a wide range of shear rate and antiplatelet therapy doses on occlusive thrombosis contributes to more accurate understanding of thrombosis and to models for optimizing patient treatment.

  14. A new approach to the estimation of radiopharmaceutical radiation dose distributions

    International Nuclear Information System (INIS)

    Hetherington, E.L.R.; Wood, N.R.

    1975-03-01

    For a photon energy of 150 keV, the Monte Carlo technique of photon history simulation was used to obtain estimates of the dose distribution in a human phantom for three activity distributions relevant to diagnostic nuclear medicine. In this preliminary work, the number of photon histories considered was insufficient to produce complete dose contours and the dose distributions are presented in the form of colour-coded diagrams. The distribution obtained illustrate an important deficiency in the MIRD Schema for dose estimation. Although the Schema uses the same mathematical technique for calculating photon doses, the results are obtained as average values for the whole body and for complete organs. It is shown that the actual dose distributions, particularly those for the whole body may, differ significantly from the average value calculated using the MIRD Schema and published absorbed fractions. (author)

  15. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    Science.gov (United States)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  16. Prospective study in the management of high-dose radioactive iodine therapy induced gastritis

    International Nuclear Information System (INIS)

    Carbonell, C.; Ogbac, R.V.

    2007-01-01

    Full text: Gastritis is simply defined as inflammation of the gastric mucosa. In post-RAI patients, this is one of the most common complications that are encountered. Some patients may even require repetitive administration of high doses of radioactive iodine (I-131). Small doses of radiation (up to 1500 R) cause reversible mucosal damage, whereas higher radiation doses cause irreversible damage with atrophy and ischemic-related ulceration. Reversible changes consist of degenerative changes in epithelial cells and nonspecific chronic inflammatory infiltrate in the lamina propria. Higher amounts of radiation cause permanent mucosal damage, with atrophy of fundic glands, mucosal erosions, and capillary hemorrhage. Associated submucosal endarteritis results in mucosal ischemia and secondary ulcer development. Recurrent gastritis, if left untreated, may be a predisposing factor for gastric malignancy. Methods:A total of thirty post-RAI subjects were evaluated for signs and symptoms of gastritis and were divided into 3 groups which were given drugs for gastritis (H2-receptor antagonist, proton pump inhibitor, and sucralfate). Survey forms were distributed to evaluate the presence of nausea, vomiting, epigastric pain (graded according to severity of pain), and gastrointestinal bleeding. Results were tallied accordingly. Results and Discussion: In a total of 3 subjects who were given sucralfate, all of them did not experience any nausea and vomiting. One subject experienced mild epigastric discomfort and another subject was able to experience a non-specific symptom of abdominal bloatedness. (Note: Subjects are still for completion) In theory, radiation irritates the mucosa causing inflammation and mucosal damage which is further irritated by gastric acid secretion. The administration of H2-receptor blockers and proton pump inhibitors only inhibit gastric acid secretion while existing inflammation of mucosa due to high doses of radiation is left untreated. However

  17. Low Dose Ionizing Radiation Modulates Immune Function

    International Nuclear Information System (INIS)

    Nelson, Gregory A.

    2016-01-01

    In order to examine the effects of low dose ionizing radiation on the immune system we chose to examine an amplified adaptive cellular immunity response. This response is Type IV delayed-type hypersensitivity also called contact hypersensitivity. The agent fluorescein isothiocyanate (FITC) is a low molecular weight, lipophilic, reactive, fluorescent molecule that can be applied to the skin where it (hapten) reacts with proteins (carriers) to become a complete antigen. Exposure to FITC leads to sensitization which is easily measured as a hypersensitivity inflammatory reaction following a subsequent exposure to the ear. Ear swelling, eosinophil infiltration, immunoglobulin E production and cytokine secretion patterns characteristic of a 'Th2 polarized' immune response are the components of the reaction. The reaction requires successful implementation of antigen processing and presentation by antigen presenting Langerhans cells, communication with naïve T lymphocytes in draining lymph nodes, expansion of activated T cell clones, migration of activated T cells to the circulation, and recruitment of memory T cells, macrophages and eosinophils to the site of the secondary challenge. Using this model our approach was to quantify system function rather than relying only on indirect biomarkers of cell. We measured the FITC-induced hypersensitivity reaction over a range of doses from 2 cGy to 2 Gy. Irradiations were performed during key events or prior to key events to deplete critical cell populations. In addition to quantifying the final inflammatory response, we assessed cell populations in peripheral blood and spleen, cytokine signatures, IgE levels and expression of genes associated with key processes in sensitization and elicitation/recall. We hypothesized that ionizing radiation would produce a biphasic effect on immune system function resulting in an enhancement at low doses and a depression at higher doses and suggested that this transition would occur in

  18. Low Dose Ionizing Radiation Modulates Immune Function

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Gregory A. [Loma Linda Univ., CA (United States)

    2016-01-12

    In order to examine the effects of low dose ionizing radiation on the immune system we chose to examine an amplified adaptive cellular immunity response. This response is Type IV delayed-type hypersensitivity also called contact hypersensitivity. The agent fluorescein isothiocyanate (FITC) is a low molecular weight, lipophilic, reactive, fluorescent molecule that can be applied to the skin where it (hapten) reacts with proteins (carriers) to become a complete antigen. Exposure to FITC leads to sensitization which is easily measured as a hypersensitivity inflammatory reaction following a subsequent exposure to the ear. Ear swelling, eosinophil infiltration, immunoglobulin E production and cytokine secretion patterns characteristic of a “Th2 polarized” immune response are the components of the reaction. The reaction requires successful implementation of antigen processing and presentation by antigen presenting Langerhans cells, communication with naïve T lymphocytes in draining lymph nodes, expansion of activated T cell clones, migration of activated T cells to the circulation, and recruitment of memory T cells, macrophages and eosinophils to the site of the secondary challenge. Using this model our approach was to quantify system function rather than relying only on indirect biomarkers of cell. We measured the FITC-induced hypersensitivity reaction over a range of doses from 2 cGy to 2 Gy. Irradiations were performed during key events or prior to key events to deplete critical cell populations. In addition to quantifying the final inflammatory response, we assessed cell populations in peripheral blood and spleen, cytokine signatures, IgE levels and expression of genes associated with key processes in sensitization and elicitation/recall. We hypothesized that ionizing radiation would produce a biphasic effect on immune system function resulting in an enhancement at low doses and a depression at higher doses and suggested that this transition would occur in the

  19. Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions

    Energy Technology Data Exchange (ETDEWEB)

    Zeng Chuan; Giantsoudi, Drosoula; Grassberger, Clemens; Goldberg, Saveli; Niemierko, Andrzej; Paganetti, Harald; Efstathiou, Jason A.; Trofimov, Alexei [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States)

    2013-05-15

    Purpose: Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. Methods: For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposed lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor

  20. Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions

    International Nuclear Information System (INIS)

    Zeng Chuan; Giantsoudi, Drosoula; Grassberger, Clemens; Goldberg, Saveli; Niemierko, Andrzej; Paganetti, Harald; Efstathiou, Jason A.; Trofimov, Alexei

    2013-01-01

    Purpose: Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. Methods: For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposed lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor

  1. Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions.

    Science.gov (United States)

    Zeng, Chuan; Giantsoudi, Drosoula; Grassberger, Clemens; Goldberg, Saveli; Niemierko, Andrzej; Paganetti, Harald; Efstathiou, Jason A; Trofimov, Alexei

    2013-05-01

    Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposed lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor control probability

  2. Relationship between dose and risk, and assessment of carcinogenic risks associated with low doses of ionizing radiation

    International Nuclear Information System (INIS)

    Tubiana, M.; Aurengo, A.

    2005-01-01

    This report raises doubts on the validity of using LNT (linear no-threshold) relationship for evaluating the carcinogenic risk of low doses (< 100 mSv) and even more for very low doses (< 10 mSv). The LNT concept can be a useful pragmatic tool for assessing rules in radioprotection for doses above 10 mSv; however since it is not based on biological concepts of our current knowledge, it should not be used without precaution for assessing by extrapolation the risks associated with low and even more so, with very low doses (< 10 mSv), especially for benefit-risk assessments imposed on radiologists by the European directive 97-43. The biological mechanisms are different for doses lower than a few dozen mSv and for higher doses. The eventual risks in the dose range of radiological examinations (0.1 to 5 mSv, up to 20 mSv for some examinations) must be estimated taking into account radiobiological and experimental data. An empirical relationship which has been just validated for doses higher than 200 mSv may lead to an overestimation of risks (associated with doses one hundred fold lower), and this overestimation could discourage patients from undergoing useful examinations and introduce a bias in radioprotection measures against very low doses (< 10 mSv). Decision makers confronted with problems of radioactive waste or risk of contamination, should re-examine the methodology used for the evaluation of risks associated with very low doses and with doses delivered at a very low dose rate. This report confirms the inappropriateness of the collective dose concept to evaluate population irradiation risks

  3. Gonad dose in cineurethrocystography

    International Nuclear Information System (INIS)

    Ardran, G.M.; Dixon-Brown, A.; Fursdon, P.S.

    1978-01-01

    The technical factors used for cineurethrocystography for the true lateral projection in females are given. The mid-line radiation dose has been measured with LiF TLD inserted into the vagina in 19 examinations. The average dose recorded was 148 mrad, the range being 50 to 306 mrad, the average number of cine frames exposed was 96. Data obtained using a Rando phantom indicated that the average ovary dose would be 30% greater than the mid-line dose since the near ovary receives a higher dose than the more distant one. The technique used for men is also given, the average gonad dose in six men being 123 mrad, range 56 to 243 mrad when simple lead foil gonad protection was used; the average number of cine frames was 107. The dose in one man without gonad protection was 1575 mrad for 112 cine frames. The results for both sexes compare favourably with those of others reported in the literature and with gonad doses recorded in typical IVP examinations. (author)

  4. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Taeko; Morishima, Hiroshige [Kinki Univ., Atomic Energy Research Institute, Osaka (Japan); Tatsumi, Kusuo [Kinki Univ., Life Science Research Institute, Osaka (Japan); Nakai, Sayaka; Sugahara, Tsutomu [Health Research Foundation, Kyoto (Japan); Yuan Yongling [Labor Hygiene Institute of Hunan Prov. (China); Wei Luxin [Laboratory of Industorial Hygiene, Ministry of Health (China)

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: (1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. (2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  5. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    International Nuclear Information System (INIS)

    Koga, Taeko; Morishima, Hiroshige; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: 1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. 2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  6. Diagnostic I-131 scintigraphy in patients with differentiated thyroid cancer. No additional value of higher scan dose

    International Nuclear Information System (INIS)

    Phan, T.T.H.; Tol, K.M. van; Links, T.P.; Piers, D.A.; Vries, E.G.E. de; Dullaart, R.P.F.; Jager, P.L.

    2004-01-01

    After initial treatment with total thyroidectomy and radio iodine ablation, most follow-up protocols for patients with differentiated thyroid carcinoma contain cyclic diagnostic I-131 imaging and serum thyroglobulin (Tg) measurements. The applied diagnostic I-131 doses vary between 37 and 370 MBq. The aim of this study was to determine the yield of a diagnostic scan with 370 MBq I-131 in patients with a negative diagnostic scan with 74 MBq I-131. Retrospective evaluation of 158 patients who received a high-dose diagnostic scan with 370 MBq I-131 because of a negative low-dose diagnostic scan with 74 MBq I-131. Special attention was paid to the patients with positive high-dose diagnostic scanning and undetectable serum Tg levels after thyroid hormone withdrawal. In 127 (80%) of patients the 370 MBq I-131 scan was negative, just like the preceding low-dose scan. In 31 (20%) of patients abnormal uptake was present on the 370 MBq diagnostic scan. In 19 of these 31 patients serum Tg was undetectable. In 15/19 the high-dose diagnostic scan proved either false positive or demonstrated clinically irrelevant minor ablation rests. In only four patients (2.5%) did the high-dose diagnostic scans reveal possibly relevant uptake caused by residual differentiated thyroid cancer. In 98% of patients a 370 MBq dose of I-131 for diagnostic whole-body scintigraphy (WBS) had no additional value. The combination of a low-dose diagnostic I-131 scan using only 74 MBq combined with a serum Tg level measurement proved sufficient for correct clinical decision making regarding whether the patient requires additional I-131 therapy. (authors)

  7. SU-G-BRC-08: Evaluation of Dose Mass Histogram as a More Representative Dose Description Method Than Dose Volume Histogram in Lung Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    Liu, J; Eldib, A; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States); Lin, M [The University of Texas Southwestern Medical Ctr, Dallas, TX (United States); Li, J [Cyber Medical Inc, Xian, Shaanxi (China); Mora, G [Universidade de Lisboa, Codex, Lisboa (Portugal)

    2016-06-15

    Purpose: Dose-volume-histogram (DVH) is widely used for plan evaluation in radiation treatment. The concept of dose-mass-histogram (DMH) is expected to provide a more representative description as it accounts for heterogeneity in tissue density. This study is intended to assess the difference between DVH and DMH for evaluating treatment planning quality. Methods: 12 lung cancer treatment plans were exported from the treatment planning system. DVHs for the planning target volume (PTV), the normal lung and other structures of interest were calculated. DMHs were calculated in a similar way as DVHs expect that the voxel density converted from the CT number was used in tallying the dose histogram bins. The equivalent uniform dose (EUD) was calculated based on voxel volume and mass, respectively. The normal tissue complication probability (NTCP) in relation to the EUD was calculated for the normal lung to provide quantitative comparison of DVHs and DMHs for evaluating the radiobiological effect. Results: Large differences were observed between DVHs and DMHs for lungs and PTVs. For PTVs with dense tumor cores, DMHs are higher than DVHs due to larger mass weighing in the high dose conformal core regions. For the normal lungs, DMHs can either be higher or lower than DVHs depending on the target location within the lung. When the target is close to the lower lung, DMHs show higher values than DVHs because the lower lung has higher density than the central portion or the upper lung. DMHs are lower than DVHs for targets in the upper lung. The calculated NTCPs showed a large range of difference between DVHs and DMHs. Conclusion: The heterogeneity of lung can be well considered using DMH for evaluating target coverage and normal lung pneumonitis. Further studies are warranted to quantify the benefits of DMH over DVH for plan quality evaluation.

  8. Tissue-phantom dose ratio R(t, F) in irradiation planning. 2

    International Nuclear Information System (INIS)

    Hegewald, H.

    1986-01-01

    The principles for measuring doses are represented to complete the developed tissue-phantom dose ratio R(t, F). The functional dependence of the tissue-phantom dose ratio on the field size results from the different spectral energy distribution in the buildup range compared to greater depths. This once more illustrates the demand, to move the calibration and reference depths into greater depths than the dose maximum depth on account of a high precision. The scattering factors and their dependence on the type of collimator are represented and tables are made up for practical use. In a supplement the derivations of the equation systems are given, to find out the tissue-phantom dose ratio by computation and the correspondence is tested. The measurements are more relevant in the megavolt range since dose values typically for the equipment are measured in the buildup range and depth dose tables are not available in the required completeness. (author)

  9. Dose-rate and humidity effects upon the gamma-radiation response of nylon-based radiachromic film dosimeters

    International Nuclear Information System (INIS)

    Gehringer, P.; Eschweiler, H.; Proksch, E.

    1979-10-01

    At dose-rates typical for 60 Co gamma irradiation sources, the radiation response of hexahydroxyethyl pararosaniline cyanide/ 50μm nylon radiachromic films is dependent upon dose-rate as well as upon the moisture content of the films, or the relative humidity of the surrounding atmosphere, respectively. Under equilibrium moisture conditions, the response measured at 606 nm 24 hours after end of irradiation shows its highest dose-rate dependence at about 32 % r.h. A decrease in dose-rate from 2.8 to 0.039 Gy.s -1 results in a decrease in response by 17%. At higher humidities, the sensitivity of the film as well as the rate dependence decreases and at 86% r.h. no discernible dose-rate effect could be found. At lower humidities than 32% a flat maximum in response follows. At nominal 0% r.h. a second absorption band at 412 nm appears which is converted completely to an additional 606 nm absorption by exposure to a humid atmosphere. After that procedure the resultant response is somewhat lower than but shows almost the same dose-rate dependence as at 32% r.h. or else to eliminate the dose-rate effect by an extrapolation procedure based on the fact that the rate dependence vanishes at zero dose. (author)

  10. Isoeffective dose: a concept for biological weighting of absorbed dose in proton and heavier-ion therapies

    CERN Document Server

    Wambersie, A; Menzel, H G; Gahbauer, R; DeLuca, P M; Hendry, J H; Jones, D T L

    2011-01-01

    When reporting radiation therapy procedures, International Commission on Radiation Units and Measurements (ICRU) recommends specifying absorbed dose at/in all clinically relevant points and/or volumes. In addition, treatment conditions should be reported as completely as possible in order to allow full understanding and interpretation of the treatment prescription. However, the clinical outcome does not only depend on absorbed dose but also on a number of other factors such as dose per fraction, overall treatment time and radiation quality radiation biology effectiveness (RBE). Therefore, weighting factors have to be applied when different types of treatments are to be compared or to be combined. This had led to the concept of `isoeffective absorbed dose', introduced by ICRU and International Atomic Energy Agency (IAEA). The isoeffective dose D(IsoE) is the dose of a treatment carried out under reference conditions producing the same clinical effects on the target volume as those of the actual treatment. It i...

  11. Relationship of dose rate and total dose to responses of continuously irradiated beagles

    International Nuclear Information System (INIS)

    Fritz, T.E.; Norris, W.P.; Tolle, D.V.; Seed, T.M.; Poole, C.M.; Lombard, L.S.; Doyle, D.E.

    1978-01-01

    Young-adult beagles were exposed continuously (22 hours/day) to 60 Co γ rays in a specially constructed facility. The exposure rates were either 5, 10, 17, or 35 R/day, and the exposures were terminated at either 600, 1400, 2000, or 4000 R. A total of 354 dogs were irradiated; 221 are still alive as long-term survivors, some after more than 2000 days. The data on survival of these dogs, coupled with data from similar preliminary experiments, allow an estimate of the LD 50 for γ-ray exposures given at a number of exposure rates. They also allow comparison of the relative importance of dose rate and total dose, and the interaction of these two variables, in the early and late effects after protracted irradiation. The LD 50 for the beagle increases from 258 rad delivered at 15 R/minute to approximately 3000 rad at 10 R/day. Over this entire range, the LD 50 is dependent upon hematopoietic damage. At 5 R/day and less, no meaningful LD 50 can be determined; there is nearly normal continued hematopoietic function, survival is prolonged, and the dogs manifest varied individual responses in other organ systems. Although the experiment is not complete, interim data allow several important conclusions. Terminated exposures, while not as effective as radiation continued until death, can produce myelogenous leukemia at the same exposure rate, 10 R/day. More importantly, at the same total accumulated dose, lower exposure rates are more damaging than higher rates on the basis of the rate and degree of hematological recovery that occurs after termination of irradiation. Thus, the rate of hematologic depression, the nadir of the depression, and the rate of recovery are dependent upon exposure rate; the latter is inversely related and the former two are directly related to exposure rate

  12. Relationship of dose rate and total dose to responses of continuously irradiated beagles

    International Nuclear Information System (INIS)

    Fritz, T.E.; Norris, W.P.; Tolle, D.V.; Seed, T.M.; Poole, C.M.; Lombard, L.S.; Doyle, D.E.

    1978-01-01

    Young-adult beagles were exposed continuously (22 hours/day) to 60 Co gamma rays in a specially constructed facility. The exposure rates were 5, 19, 17 or 35 R/day, and the exposures were terminated at 600, 1400, 2000 or 4000 R. A total of 354 dogs were irradiated; 221 are still alive as long-term survivors, some after more than 2000 days. The data on survival of these dogs, coupled with data from similar preliminary experiments, allow an estimate of the LD 50 for gamma-ray exposures given at a number of exposure rates. They also allow comparison of the relativeimportance of dose rate and total dose, and the interaction of these two variables, in the early and late effects after protracted irradiation. The LD 50 for the beagle increases from 344 R (258 rads) delivered at 15 R/minute to approximately 4000 R (approximately 3000 rads) at 10 R/day. Over this entire range, the LD 50 is dependent upon haematopoietic damage. At 5 R/day and less, no definitive LD 50 can be determined; there is nearly normal continued haematopoietic function, survival is prolonged, and the dogs manifest varied individual responses in the organ systems. Although the experiment is not complete, interim data allow serveral important conclusions. Terminated exposures, while not as effective as irradiation continued until death, can produce myelogenous leukaemia at the same exposure rate, 10 R/day. More importantly, at the same total accumulated dose, lower exposure rates appear more damaging than higher rates on the basis of the rate and degree of haematological recovery that occurs after termination of irradiation. Thus, the rate of haematologic depression, the nadir of the depression and the rate of recovery are dependent upon exposure rate; the latter is inversely related and the first two are directly related to exposure rate. ( author)

  13. dose in cervical cancer intracavitary brachytherapy

    Directory of Open Access Journals (Sweden)

    Zahra Siavashpour

    2016-04-01

    Full Text Available Purpose: To analyze the optimum organ filling point for organs at risk (OARs dose in cervical cancer high-dose-rate (HDR brachytherapy. Material and methods : In a retrospective study, 32 locally advanced cervical cancer patients (97 insertions who were treated with 3D conformal external beam radiation therapy (EBRT and concurrent chemotherapy during 2010-2013 were included. Rotterdam HDR tandem-ovoid applicators were used and computed tomography (CT scanning was performed after each insertion. The OARs delineation and GEC-ESTRO-based clinical target volumes (CTVs contouring was followed by 3D forward planning. Then, dose volume histogram (DVH parameters of organs were recorded and patients were classified based on their OARs volumes, as well as their inserted tandem length. Results : The absorbed dose to point A ranged between 6.5-7.5 Gy. D 0.1cm ³ and D 2cm ³ of the bladder significantly increased with the bladder volume enlargement (p value < 0.05. By increasing the bladder volume up to about 140 cm3, the rectum dose was also increased. For the cases with bladder volumes higher than 140 cm3, the rectum dose decreased. For bladder volumes lower than 75 cm3, the sigmoid dose decreased; however, for bladder volumes higher than 75 cm3, the sigmoid dose increased. The D 2cm ³ of the bladder and rectum were higher for longer tandems than for shorter ones, respectively. The divergence of the obtained results for different tandem lengths became wider by the extension of the bladder volume. The rectum and sigmoid volume had a direct impact on increasing their D 0.1cm ³ and D 2cm ³, as well as decreasing their D 10 , D 30 , and D 50 . Conclusions : There is a relationship between the volumes of OARs and their received doses. Selecting a bladder with a volume of about 70 cm3 or less proved to be better with regards to the dose to the bladder, rectum, and sigmoid.

  14. Retrospective Dosimetric Comparison of Low-Dose-Rate and Pulsed-Dose-Rate Intracavitary Brachytherapy Using a Tandem and Mini-Ovoids

    International Nuclear Information System (INIS)

    Mourtada, Firas; Gifford, Kent A.; Berner, Paula A.; Horton, John L.; Price, Michael J.; Lawyer, Ann A.; Eifel, Patricia J.

    2007-01-01

    The purpose of this study was to compare the dose distribution of Iridium-192 ( 192 Ir) pulsed-dose-rate (PDR) brachytherapy to that of Cesium-137 ( 137 Cs) low-dose-rate (LDR) brachytherapy around mini-ovoids and an intrauterine tandem. Ten patient treatment plans were selected from our clinical database, all of which used mini-ovoids and an intrauterine tandem. A commercial treatment planning system using AAPM TG43 formalism was used to calculate the dose in water for both the 137 Cs and 192 Ir sources. For equivalent system loadings, we compared the dose distributions in relevant clinical planes, points A and B, and to the ICRU bladder and rectal reference points. The mean PDR doses to points A and B were 3% ± 1% and 6% ± 1% higher than the LDR doses, respectively. For the rectum point, the PDR dose was 4% ± 3% lower than the LDR dose, mainly because of the 192 Ir PDR source anisotropy. For the bladder point, the PDR dose was 1% ± 4% higher than the LDR dose. We conclude that the PDR and LDR dose distributions are equivalent for intracavitary brachytherapy with a tandem and mini-ovoids. These findings will aid in the transfer from the current practice of LDR intracavitary brachytherapy to PDR for the treatment of gynecologic cancers

  15. A randomized controlled trial of increased dose and frequency of albendazole with standard dose DEC for treatment of Wuchereria bancrofti microfilaremics in Odisha, India.

    Science.gov (United States)

    Kar, Shantanu Kumar; Dwibedi, Bhagirathi; Kerketa, Anna Salomi; Maharana, Antaryami; Panda, Sudanshu S; Mohanty, Prafulla Chandra; Horton, John; Ramachandran, Cherubala P

    2015-03-01

    Although current programmes to eliminate lymphatic filariasis have made significant progress it may be necessary to use different approaches to achieve the global goal, especially where compliance has been poor and 'hot spots' of continued infection exist. In the absence of alternative drugs, the use of higher or more frequent dosing with the existing drugs needs to be explored. We examined the effect of higher and/or more frequent dosing with albendazole with a fixed 300 mg dose of diethylcarbamazine in a Wuchereria bancrofti endemic area in Odisha, India. Following screening, 104 consenting adults were randomly assigned to treatment with the standard regimen annually for 24 months (S1), or annually with increased dose (800 mg albendazole)(H1) or with increased frequency (6 monthly) with either standard (S2) or increased (H2) dose. Pre-treatment microfilaria counts (GM) ranged from 348 to 459 mf/ml. Subjects were followed using microfilaria counts, OG4C3 antigen levels and ultrasound scanning for adult worm nests. Microfilarial counts tended to decrease more rapidly with higher or more frequent dosing at all time points. At 12 months, Mf clearance was marginally greater with the high dose regimens, while by 24 months, there was a trend to higher Mf clearance in the arm with increased frequency and 800 mg of albendazole (76.9%) compared to other arms, (S1:64%, S2:69.2% & H1:73.1%). Although higher and/or more frequent dosing showed a trend towards a greater decline in antigenemia and clearance of "nests", all regimens demonstrated the potential macrofilaricidal effect of the combination. The higher doses of albendazole did not result in a greater number or more severe side effects. The alternative regimens could be useful in the later stages of existing elimination programmes or achieving elimination more rapidly in areas where programmes have yet to start.

  16. Effect of Admission Oral Diuretic Dose on Response to Continuous versus Bolus Intravenous Diuretics in Acute Heart Failure: An Analysis from DOSE-AHF

    Science.gov (United States)

    Shah, Ravi V.; McNulty, Steven; O'Connor, Christopher M.; Felker, G. Michael; Braunwald, Eugene; Givertz, Michael M.

    2014-01-01

    Background Results from the Diuretic Optimization Strategies in Acute Heart Failure (DOSE-AHF) study suggest that an initial continuous infusion of loop diuretics is not superior to bolus dosing with regard to clinical endpoints in AHF. We hypothesized that outpatient furosemide dose was associated with congestion and poorer renal function, and explored the hypothesis that a continuous infusion may be more effective in patients on higher outpatient diuretic doses. Methods DOSE-AHF randomized 308 patients within 24 hours of admission to high vs. low initial intravenous diuretic dose given as either a continuous infusion or bolus. We compared baseline characteristics and assessed associations between mode of administration (bolus vs. continuous) and outcomes in patients receiving high-dose (≥120 mg furosemide equivalent, n=177) versus low-dose (diuretics. Results Patients on higher doses of furosemide were less frequently on renin-angiotensin system inhibitors (P=.01), and had worse renal function and more advanced symptoms. There was a significant interaction between outpatient dose and mode of therapy (P=0.01) with respect to net fluid loss at 72 hours after adjusting for creatinine and intensification strategy. Admission diuretic dose was associated with an increased risk of death or rehospitalization at 60 days (adjusted HR=1.08 per 20-mg increment in dose, 95% CI 1.01–1.16, P=.03). Conclusions In acute HF, patients on higher diuretic doses have greater disease severity, and may benefit from an initial bolus strategy. PMID:23194486

  17. Ambient radiation dose reduction within a newly remodeled Nuclear Medicine Department

    International Nuclear Information System (INIS)

    Lai, Y.C.; Chen, Y.W.; Huang, Y.F.

    2008-01-01

    Full text: Ambient radiation levels at the patient waiting areas have been greatly reduced after remodeling of our Nuclear Medicine Department (NMD) based on the ALARA consideration. Complete ambient radiation monitoring of our NMD before remodeling had been characterized and published earlier by the same authors elsewhere. The NMD outpatients, with an initial dose of up to 740 MBq (20 mCi) per case, may wait around and incidentally congest in one place that could cause an unexpected higher exposure level in public access areas. In this new surveillance study after remodeling, the ambient radiation time-profile, peak dose rates and daily doses have been re-evaluated by using high sensitivity, digital survey dosimeters. As a preliminary result, with our newly improved facility in operation, we have demonstrated the NMD waiting room average daily dose has dropped from about 3.0 μSv to 0.42 μSv during most of busy days in comparison. The hourly peak dose rate detected in patient waiting areas has also reduced to a factor of more than two, from maximum dose rate of 40.4 μSv/h to 15.4 μSv/h, during one worst case scenario. The great reduction of the environment dose was achieved mainly by using larger room space with thicker lead wall, from previous 2-mm to new 5-mm in lead thickness, and by increasing patient waiting rooms/areas with less chairs available in each seating location. Other NMD administrative control measure of our dose reduction program has also been emphasized in better patient routing, scheduling and less waiting time for the diagnostic patients. (author)

  18. Dose assessment at Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Phillips, W.A.; Colsher, C.S.

    1977-01-01

    Bikini Atoll is one of two sites in the northern Marshall Islands that was used by the United States as testing grounds for the nuclear weapons program from 1946 to 1958. In 1969 a general cleanup began at Bikini Atoll. Subsistence crops, coconut and Pandanus fruit, were planted on Bikini and Eneu Islands, and housing was constructed on Bikini Island. A second phase of housing was planned for the interior of Bikini Island. Preliminary data indicated that external gamma doses in the interior of the island might be higher than in other parts of the island. Therefore, to select a second site for housing on the island with minimum external exposure, a survey of Bikini Atoll was conducted in June 1975. External gamma measurements were made on Bikini and Eneu Islands, and soil and vegetations samples collected to evaluate the potential doses via terrestrial food chains and inhalation. Estimates of potential dose via the marine food chain were based upon data collected on previous trips to the atoll. The terrestrial pathway contributes the greater percentage, external gamma exposure contributes the next highest, and inhalation and marine pathways contribute minor fractions of the total whole body and bone marrow doses. The radionuclides contributing the major fraction of the dose are 90 Sr and 137 Cs. All living patterns involving Bikini Island exceed federal guidelines for 30-yr population doses. The Eneu Island living pattern leads to doses that are slightly less than federal guidelines. All patterns evaluated for Bikini Atoll lead to higher doses than those on the southern islands at Enewetak Atoll

  19. ELDRS Characterization for a Very High Dose Mission

    Science.gov (United States)

    Harris, Richard D.; McClure, Steven S.; Rax, Bernard G.; Kenna, Aaron J.; Thorbourn, Dennis O.; Clark, Karla B.; Yan, Tsun-Yee

    2010-01-01

    Evaluation of bipolar linear parts which may have Enhanced Low Dose Rate Sensitivity (ELDRS) is problematic for missions that have very high dose radiation requirements. The accepted standards for evaluating parts that display ELDRS require testing at a very low dose rate which could be prohibitively long for very high dose missions. In this work, a methodology for ELDRS characterization of bipolar parts for mission doses up to 1 Mrad(Si) is evaluated. The procedure employs an initial dose rate of 0.01 rad(Si)/s to a total dose of 50 krad(Si) and then changes to 0.04 rad(Si)/s to a total dose of 1 Mrad(Si). This procedure appears to work well. No change in rate of degradation with dose has been observed when the dose rate is changed from 0.01 to 0.04 rad(Si)/s. This is taken as an indication that the degradation due to the higher dose rate is equivalent to that at the lower dose rate at the higher dose levels, at least for the parts studied to date. In several cases, significant parameter degradation or functional failure not observed at HDR was observed at fairly high total doses (50 to 250 krad(Si)) at LDR. This behavior calls into question the use of dose rate trend data and enhancement factors to predict LDR performance.

  20. Outdoor γ-ray dose rate in Shariki Village and environmental factors affecting outdoor γ-ray dose rate in IES

    International Nuclear Information System (INIS)

    Iyogi, Takashi; Hisamatsu, Shun'ichi; Inaba, Jiro

    2000-01-01

    Previously, we surveyed the outdoor γ-ray dose rate throughout Aomori Prefecture from 1992 to 1995, and found an annual mean dose rate of 51 nGy h -1 . Relatively high dose rates were also observed in several areas (municipalities) of the survey locations. In this study, we examined the detailed distribution of the γ-ray dose rate in one such high dose rate area, Shariki Village. Glass dosemeters were used for the monitoring of cumulative γ-ray dose rate at 10 locations in the village. The dose rate from each radioactive nuclide in the ground at the monitoring locations was measured by using an in situ γ-ray spectrometer with a Ge detector. The results obtained with the glass dosemeters showed that the γ-ray dose rates in Shariki Village varied from 49 to 55 nGy h -1 . Although the dose rates were generally higher than the mean dose in Aomori Prefecture (1992-1995), the rates were lower than other high dose rate areas which had already been measured. The in situ γ-ray spectrometry revealed that these relatively high dose rates were mainly caused by 40 K and Th series radionuclides in the village. The effect of meteorological conditions on the γ-ray dose rate was studied at a monitoring station in the IES site. The dose rate was continuously recorded by a DBM NaI(Tl) scintillation detector system. The mean dose rate obtained when precipitation was sensed was 27 nGy h -1 and higher than when no precipitation was sensed (25 nGy h -1 ). (author)

  1. Interim report of image-guided conformal high-dose-rate brachytherapy for patients with unfavorable prostate cancer: the William Beaumont Phase II dose-escalating trial

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Kestin, Larry L.; Stromberg, Jannifer S.; Gonzalez, Jose A.; Wallace, Michelle; Gustafson, Gary S.; Edmundson, Gregory K.; Spencer, William; Vicini, Frank A.

    2000-01-01

    biopsy Gleason score was ≥ 7 in 58% of cases, and 75% of cases were clinical stage T2b or higher. Despite the high frequency of these poor prognostic factors, the actuarial biochemical control rate was 89% at 2 years and 63% at 5 years. On multivariate analysis, a higher pretreatment PSA level, higher Gleason score, higher PSA nadir level, and shorter time to nadir were associated with biochemical failure. In the entire population, 14 patients (10%) experienced clinical failure at a median interval of 1.7 years (range: 0.2-4.5 years) after completing RT. The 5-year actuarial clinical failure rate was 22%. The 5-year actuarial rates of local failure and distant metastasis were 16% and 14%, respectively. For all patients, the 5-year disease-free survival, overall survival, and cause-specific survival rates were 89%, 95%, and 96%, respectively. The 5-year actuarial rate of RTOG Grade 3 late complications was 9% with no patient experiencing Grade 4 or 5 acute or late toxicity. Conclusion: Pelvic EBRT in combination with image-guided conformal HDR brachytherapy boosts appears to be an effective treatment for patients with unfavorable prostate cancer with minimal associated morbidity. Our dose-escalating trial will continue

  2. Moderate- vs high-dose methadone in the treatment of opioid dependence: a randomized trial.

    Science.gov (United States)

    Strain, E C; Bigelow, G E; Liebson, I A; Stitzer, M L

    1999-03-17

    Methadone hydrochloride treatment is the most common pharmacological intervention for opioid dependence, and recent interest has focused on expanding methadone treatment availability beyond traditional specially licensed clinics. However, despite recommendations regarding effective dosing of methadone, controlled clinical trials of higher-dose methadone have not been conducted. To compare the relative clinical efficacy of moderate- vs high-dose methadone in the treatment of opioid dependence. A 40-week randomized, double-blind clinical trial starting in June 1992 and ending in October 1995. Outpatient substance abuse treatment research clinic at the Johns Hopkins University Bayview Campus, Baltimore, Md. One hundred ninety-two eligible clinic patients. Daily oral methadone hydrochloride in the dose range of 40 to 50 mg (n = 97) or 80 to 100 mg (n = 95), with concurrent substance abuse counseling. Opioid-positive urinalysis results and retention in treatment. By intent-to-treat analysis through week 30 patients in the high-dose group had significantly lower rates of opioid-positive urine samples compared with patients in the moderate-dose group (53.0% [95% confidence interval [CI], 46.9%-59.2%] vs 61.9% [95% CI, 55.9%-68.0%]; P = .047. These differences persisted during withdrawal from methadone. Through day 210 no significant difference was evident between dose groups in treatment retention (high-dose group mean retention, 159 days; moderate-dose group mean retention, 157 days). Nineteen (33%) of 57 patients in the high-dose group and 11 (20%) of 54 patients in the moderate-dose group completed detoxification. Both moderate- and high-dose methadone treatment resulted in decreased illicit opioid use during methadone maintenance and detoxification. The high-dose group had significantly greater decreases in illicit opioid use.

  3. Determination of tolerance dose uncertainties and optimal design of dose response experiments with small animal numbers

    International Nuclear Information System (INIS)

    Karger, C.P.; Hartmann, G.H.

    2001-01-01

    Background: Dose response experiments aim to determine the complication probability as a function of dose. Adjusting the parameters of the frequently used dose response model P(D)=1/[1+(D 50 /D) k ] to the experimental data, 2 intuitive quantities are obtained: The tolerance dose D 50 and the slope parameter k. For mathematical reasons, however, standard statistic software uses a different set of parameters. Therefore, the resulting fit parameters of the statistic software as well as their standard errors have to be transformed to obtain D 50 and k as well as their standard errors. Material and Methods: The influence of the number of dose levels on the uncertainty of the fit parameters is studied by a simulation for a fixed number of animals. For experiments with small animal numbers, statistical artifacts may prevent the determination of the standard errors of the fit parameters. Consequences on the design of dose response experiments are investigated. Results: Explicit formulas are presented, which allow to calculate the parameters D 50 and k as well as their standard errors from the output of standard statistic software. The simulation shows, that the standard errors of the resulting parameters are independent of the number of dose levels, as long as the total number of animals involved in the experiment, remains constant. Conclusion: Statistical artifacts in experiments containing small animal numbers may be prevented by an adequate design of the experiment. For this, it is suggested to select a higher number of dose levels, rather than using a higher number of animals per dose level. (orig.) [de

  4. Experimental evaluation of neutron dose in radiotherapy patients: Which dose?

    Energy Technology Data Exchange (ETDEWEB)

    Romero-Expósito, M., E-mail: mariateresa.romero@uab.cat; Domingo, C.; Ortega-Gelabert, O.; Gallego, S. [Grup de Recerca en Radiacions Ionizants (GRRI), Departament de Física, Universitat Autònoma de Barcelona, Bellaterra 08193 (Spain); Sánchez-Doblado, F. [Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla 41009 (Spain); Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41009 (Spain)

    2016-01-15

    Purpose: The evaluation of peripheral dose has become a relevant issue recently, in particular, the contribution of secondary neutrons. However, after the revision of the Recommendations of the International Commission on Radiological Protection, there has been a lack of experimental procedure for its evaluation. Specifically, the problem comes from the replacement of organ dose equivalent by the organ-equivalent dose, being the latter “immeasurable” by definition. Therefore, dose equivalent has to be still used although it needs the calculation of the radiation quality factor Q, which depends on the unrestricted linear energy transfer, for the specific neutron irradiation conditions. On the other hand, equivalent dose is computed through the radiation weighting factor w{sub R}, which can be easily calculated using the continuous function provided by the recommendations. The aim of the paper is to compare the dose equivalent evaluated following the definition, that is, using Q, with the values obtained by replacing the quality factor with w{sub R}. Methods: Dose equivalents were estimated in selected points inside a phantom. Two types of medical environments were chosen for the irradiations: a photon- and a proton-therapy facility. For the estimation of dose equivalent, a poly-allyl-diglicol-carbonate-based neutron dosimeter was used for neutron fluence measurements and, additionally, Monte Carlo simulations were performed to obtain the energy spectrum of the fluence in each point. Results: The main contribution to dose equivalent comes from neutrons with energy higher than 0.1 MeV, even when they represent the smallest contribution in fluence. For this range of energy, the radiation quality factor and the radiation weighting factor are approximately equal. Then, dose equivalents evaluated using both factors are compatible, with differences below 12%. Conclusions: Quality factor can be replaced by the radiation weighting factor in the evaluation of dose

  5. Protective effect of hypoxia in the ram testis during single and split-dose X-irradiation

    International Nuclear Information System (INIS)

    Vliet, J. van; Wensing, C.J.G.; Bootsma, A.L.; Peperzeel, H.A. van; Schipper, J.

    1988-01-01

    Spertogonial stem-cell survival in the ram was studied after single (6Gy) and split-dose X-irradiation both under normal and hypoxic conditions. Hypoxia was induced by inflation of an occluder implanted around the testicular artery. The occluders were inflated about 10 min before irradiation and deflated immediately after. Stem-cell survival was measured at 5 or 7 weeks after irradiation by determination of the Repopulation Index (RI) in histological testis sections. The RI-values after fractionated irradiation were only half those after single dose irradiation. Hypoxia had a protective effect on the stem-cell survival. After split-dose irradiation under hypoxic conditions two times more stem cells survived than under normal oxic conditions; the RI-values increased from 34% (oxic) to 68% (hypoxic). This effect of hypoxia was also found after single dose irradiation where the RI-values increased from 68% (oxic) to 84% (hypoxic). The development of the epithelium in repopulated tubules was also studied. Under hypoxia, a significantly higher fraction of tubules with complete epithelium was found after single (38 vs. 4%) as well as after split-dose irradiation (12 vs. 0%)

  6. Research on low radiation doses - A better understanding of low doses

    International Nuclear Information System (INIS)

    2016-01-01

    Radiation doses below 100 mSv are called low doses. Epidemiological research on the health hazards of low doses are difficult to do because numerous pathologies, particularly cancer, appear lifelong for genetical or environmental causes without any link with irradiation and it is very difficult to identify the real cause of a cancer. Another concern is that the impact on human health is weak and are observed only after a long period after irradiation. These features make epidemiological studies cumbersome to implement since they require vast cohorts and a very long-term follow-up. The extrapolation of the effects of higher doses to the domain of low doses does not meet reality and it is why the European Union takes part into the financing of such research. In order to gain efficiency, scientists work together through various European networks among them: HLEG (High Level Expert Group On European Low Dose Risk Research) or MELODI (Multidisciplinary European Low Dose Initiative). Several programs are underway or have been recently launched: -) the impact of Cesium contamination on children's health (Epice program), -) the study of the impact of medical imaging on children, -) the study of the health of children living near nuclear facilities, -) the relationship between radon and lung cancer, -) the effect of occupational low radiation doses, -) the effect of uranium dissolved in water on living organisms (Envirhom program). (A.C.)

  7. Radiolysis of Aqueous Benzene Solutions at higher temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, H

    1964-07-15

    Aqueous solutions of benzene have been irradiated with Co {gamma}-rays with doses of up to 2.3 Mrad in the temperature region 100 - 200 C. At 100 C a linear relationship between the phenol concentration and the absorbed dose was obtained, but at 150 C and at higher temperatures the rate of the phenol formation increased significantly after an initial constant period. With higher doses the rate decreased again, falling almost to zero at 200 C after a dose of 2.2 Mrad. The G value of phenol in the initial linear period increased from 2.8 at 100 C to 8.0 at 200 C. The reaction mechanism is discussed and reactions constituting a chain reaction are suggested. The result of the addition of iron ions and of a few inorganic oxides to the system is presented and briefly discussed.

  8. Radiolysis of Aqueous Benzene Solutions at higher temperatures

    International Nuclear Information System (INIS)

    Christensen, H.

    1964-07-01

    Aqueous solutions of benzene have been irradiated with Co γ-rays with doses of up to 2.3 Mrad in the temperature region 100 - 200 C. At 100 C a linear relationship between the phenol concentration and the absorbed dose was obtained, but at 150 C and at higher temperatures the rate of the phenol formation increased significantly after an initial constant period. With higher doses the rate decreased again, falling almost to zero at 200 C after a dose of 2.2 Mrad. The G value of phenol in the initial linear period increased from 2.8 at 100 C to 8.0 at 200 C. The reaction mechanism is discussed and reactions constituting a chain reaction are suggested. The result of the addition of iron ions and of a few inorganic oxides to the system is presented and briefly discussed

  9. Maximal safe dose of I-131 after failure of standard fixed dose therapy in patients with differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Lee, Jong-Jin; Chung, June-Key; Kim, Sung-Eun; Kang, Won-Jun; Park, Do-Joon; Lee, Dong-Soo; Cho, Bo-Youn; Lee, Myung-Chul

    2008-01-01

    The maximal safe dose (MSD) on the basis of bone marrow irradiation levels allows the delivery of a large amount of I-131 to thyroid cancer tissue. The efficacy of MSD therapy in differentiated metastatic thyroid cancers that persisted after conventional fixed dose therapy is investigated. Forty-seven differentiated thyroid carcinoma patients with non-responsive residual disease despite repetitive fixed dose I-131 therapy were enrolled in this study. Their postoperative pathologies were 43 papillary carcinomas and 4 follicular carcinomas. The MSD was calculated with the Memorial Sloan-Kettering Cancer Center protocol using serial blood samples. The MSDs were administered at intervals of 6 months. Treatment responses were evaluated using I-131 whole-body scans and serum thyroglobulin measurements. The mean calculated MSD was 12.5±2.1 GBq (339.6±57.5 mCi). Of the 46 patients, 7 (14.9%) showed complete remission, 15 (31.9%) partial remission, 19 (40.4%) stable disease, and 6 (12.8%) disease progression. Of the patients who showed complete or partial remission, 15 (65%) showed response after the first MSD session and 6 (26%) showed response after the second session. Twenty-nine patients (62%) experienced transient cytopenia after therapy, but three did not recover to the baseline level. The maximal safe dose provides an effective means of treatment in patients who failed to respond adequately to conventional fixed dose therapy. I-131 MSD therapy can be considered in patients who fail fixed dose therapy. (author)

  10. From physical dose constraints to equivalent uniform dose constraints in inverse radiotherapy planning

    International Nuclear Information System (INIS)

    Thieke, Christian; Bortfeld, Thomas; Niemierko, Andrzej; Nill, Simeon

    2003-01-01

    Optimization algorithms in inverse radiotherapy planning need information about the desired dose distribution. Usually the planner defines physical dose constraints for each structure of the treatment plan, either in form of minimum and maximum doses or as dose-volume constraints. The concept of equivalent uniform dose (EUD) was designed to describe dose distributions with a higher clinical relevance. In this paper, we present a method to consider the EUD as an optimization constraint by using the method of projections onto convex sets (POCS). In each iteration of the optimization loop, for the actual dose distribution of an organ that violates an EUD constraint a new dose distribution is calculated that satisfies the EUD constraint, leading to voxel-based physical dose constraints. The new dose distribution is found by projecting the current one onto the convex set of all dose distributions fulfilling the EUD constraint. The algorithm is easy to integrate into existing inverse planning systems, and it allows the planner to choose between physical and EUD constraints separately for each structure. A clinical case of a head and neck tumor is optimized using three different sets of constraints: physical constraints for all structures, physical constraints for the target and EUD constraints for the organs at risk, and EUD constraints for all structures. The results show that the POCS method converges stable and given EUD constraints are reached closely

  11. Out‐of‐field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators

    Science.gov (United States)

    Cardenas, Carlos E.; Nitsch, Paige L.; Kudchadker, Rajat J.; Howell, Rebecca M.

    2016-01-01

    Out‐of‐field doses from radiotherapy can cause harmful side effects or eventually lead to secondary cancers. Scattered doses outside the applicator field, neutron source strength values, and neutron dose equivalents have not been broadly investigated for high‐energy electron beams. To better understand the extent of these exposures, we measured out‐of‐field dose characteristics of electron applicators for high‐energy electron beams on two Varian 21iXs, a Varian TrueBeam, and an Elekta Versa HD operating at various energy levels. Out‐of‐field dose profiles and percent depth‐dose curves were measured in a Wellhofer water phantom using a Farmer ion chamber. Neutron dose was assessed using a combination of moderator buckets and gold activation foils placed on the treatment couch at various locations in the patient plane on both the Varian 21iX and Elekta Versa HD linear accelerators. Our findings showed that out‐of‐field electron doses were highest for the highest electron energies. These doses typically decreased with increasing distance from the field edge but showed substantial increases over some distance ranges. The Elekta linear accelerator had higher electron out‐of‐field doses than the Varian units examined, and the Elekta dose profiles exhibited a second dose peak about 20 to 30 cm from central‐axis, which was found to be higher than typical out‐of‐field doses from photon beams. Electron doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. With respect to neutron dosimetry, Q values and neutron dose equivalents increased with electron beam energy. Neutron contamination from electron beams was found to be much lower than that from photon beams. Even though the neutron dose equivalent for electron beams represented a small portion of neutron doses observed under photon beams, neutron doses from electron beams may need to be considered for

  12. Out-of-field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators.

    Science.gov (United States)

    Cardenas, Carlos E; Nitsch, Paige L; Kudchadker, Rajat J; Howell, Rebecca M; Kry, Stephen F

    2016-07-08

    Out-of-field doses from radiotherapy can cause harmful side effects or eventually lead to secondary cancers. Scattered doses outside the applicator field, neutron source strength values, and neutron dose equivalents have not been broadly investigated for high-energy electron beams. To better understand the extent of these exposures, we measured out-of-field dose characteristics of electron applicators for high-energy electron beams on two Varian 21iXs, a Varian TrueBeam, and an Elekta Versa HD operating at various energy levels. Out-of-field dose profiles and percent depth-dose curves were measured in a Wellhofer water phantom using a Farmer ion chamber. Neutron dose was assessed using a combination of moderator buckets and gold activation foils placed on the treatment couch at various locations in the patient plane on both the Varian 21iX and Elekta Versa HD linear accelerators. Our findings showed that out-of-field electron doses were highest for the highest electron energies. These doses typically decreased with increasing distance from the field edge but showed substantial increases over some distance ranges. The Elekta linear accelerator had higher electron out-of-field doses than the Varian units examined, and the Elekta dose profiles exhibited a second dose peak about 20 to 30 cm from central-axis, which was found to be higher than typical out-of-field doses from photon beams. Electron doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. With respect to neutron dosimetry, Q values and neutron dose equivalents increased with electron beam energy. Neutron contamination from electron beams was found to be much lower than that from photon beams. Even though the neutron dose equivalent for electron beams represented a small portion of neutron doses observed under photon beams, neutron doses from electron beams may need to be considered for special cases.

  13. Incidence of late rectal bleeding in high-dose conformal radiotherapy of prostate cancer using equivalent uniform dose-based and dose-volume-based normal tissue complication probability models

    International Nuclear Information System (INIS)

    Soehn, Matthias; Yan Di; Liang Jian; Meldolesi, Elisa; Vargas, Carlos; Alber, Markus

    2007-01-01

    Purpose: Accurate modeling of rectal complications based on dose-volume histogram (DVH) data are necessary to allow safe dose escalation in radiotherapy of prostate cancer. We applied different equivalent uniform dose (EUD)-based and dose-volume-based normal tissue complication probability (NTCP) models to rectal wall DVHs and follow-up data for 319 prostate cancer patients to identify the dosimetric factors most predictive for Grade ≥ 2 rectal bleeding. Methods and Materials: Data for 319 patients treated at the William Beaumont Hospital with three-dimensional conformal radiotherapy (3D-CRT) under an adaptive radiotherapy protocol were used for this study. The following models were considered: (1) Lyman model and (2) logit-formula with DVH reduced to generalized EUD (3) serial reconstruction unit (RU) model (4) Poisson-EUD model, and (5) mean dose- and (6) cutoff dose-logistic regression model. The parameters and their confidence intervals were determined using maximum likelihood estimation. Results: Of the patients, 51 (16.0%) showed Grade 2 or higher bleeding. As assessed qualitatively and quantitatively, the Lyman- and Logit-EUD, serial RU, and Poisson-EUD model fitted the data very well. Rectal wall mean dose did not correlate to Grade 2 or higher bleeding. For the cutoff dose model, the volume receiving > 73.7 Gy showed most significant correlation to bleeding. However, this model fitted the data more poorly than the EUD-based models. Conclusions: Our study clearly confirms a volume effect for late rectal bleeding. This can be described very well by the EUD-like models, of which the serial RU- and Poisson-EUD model can describe the data with only two parameters. Dose-volume-based cutoff-dose models performed worse

  14. Hydroponic cultivation of Physalis angulata L.: growth and production under nitrogen doses

    Directory of Open Access Journals (Sweden)

    Romeu da Silva Leite

    2017-06-01

    Full Text Available The Physalis angulata L. species has attracted interest due to the production of compounds with pharmacological activity and its potential for fruiticulture. Given that it is a fast-growing and highly productive species, determining the most adequate nitrogen (N doses could contribute to higher crop yields. This study aimed at assessing the influence of N concentrations, in a hydroponic system, on the growth and production of P. angulata, as well as determining the critical N level in leaves. The experiment was conducted in individual pots with nutrient solutions, applying a completely randomized design and twelve replications, using five N doses (0 mg L-1, 56 mg L-1, 112 mg L-1, 168 mg L-1 and 224 mg L-1. Growth and production indices, amount of total N on leaves and stems and critical N levels were assessed. The increase of N doses in the nutrient solution influenced plant growth and fruit production, as well as the accumulation of total N in the leaves and stems. Based on the maximum economic yield, a dose of 162 mg L-1 of N is recommended for hydroponics, which provided a fruit yield of 7.27 g m-2 and critical total N level in leaves of 51.98 g kg-1.

  15. Relationships between thermal dose parameters and the efficacy of definitive chemoradiotherapy plus regional hyperthermia in the treatment of locally advanced cervical cancer: data from a multicentre randomised clinical trial.

    Science.gov (United States)

    Ohguri, Takayuki; Harima, Yoko; Imada, Hajime; Sakurai, Hideyuki; Ohno, Tatsuya; Hiraki, Yoshiyuki; Tuji, Koh; Tanaka, Masahiro; Terashima, Hiromi

    2018-06-01

    To evaluate the contribution of the thermal dose parameters during regional hyperthermia (HT) treatment to the clinical outcomes in patients with cervical carcinoma (CC) who received chemoradiotherapy (CRT) plus HT. Data from a multicentre randomised clinical trial of concurrent CRT + HT vs. CRT alone were used to evaluate the efficacy and safety of this combination therapy in the CC patients. The intrarectal temperatures of patients undergoing HT were recorded. The complete thermal data of 47 (92%) of the 51 patients in the CRT + HT group were available for the thermal analysis. Thus, 47 patients who received CRT + HT were included in the present study. Among the patients who received CRT + HT, a higher CEM43T90 (≥1 min) value (a thermal dose parameter) was significantly associated with better local relapse-free survival in both univariate (p = 0.024) and multivariate (p = 0.0097) analyses. The disease-free survival of the patients with higher CEM43T90 (≥1 min) values tended to be better in comparison to patients with lower CEM43T90 (<1 min) value (p = 0.071). A complete response tended to be associated with the CEM43T90 (p = 0.056). Disease-free survival, local relapse-free survival and complete response rate for patients with higher CEM43T90 (≥1) were significantly better than those for patients with CRT alone (p = 0.036, p = 0.036 and p = 0.048). Dose-effect relationships between thermal dose parameters and clinical outcomes were confirmed in the CC patients treated with a combination of CRT + HT. This study also confirmed that HT with lower CEM43T90 is insufficient to achieve a significant hyperthermic sensitisation to CRT.

  16. Enjebi Island dose assessment

    International Nuclear Information System (INIS)

    Robison, W.L.; Conrado, C.L.; Phillips, W.A.

    1987-07-01

    We have updeated the radiological dose assessment for Enjebi Island at Enewetak Atoll using data derived from analysis of food crops grown on Enjebi. This is a much more precise assessment of potential doses to people resettling Enjebi Island than the 1980 assessment in which there were no data available from food crops on Enjebi. Details of the methods and data used to evaluate each exposure pathway are presented. The terrestrial food chain is the most significant potential exposure pathway and 137 Cs is the radionuclide responsible for most of the estimated dose over the next 50 y. The doses are calculated assuming a resettlement date of 1990. The average wholebody maximum annual estimated dose equivalent derived using our diet model is 166 mremy;the effective dose equivalent is 169 mremy. The estimated 30-, 50-, and 70-y integral whole-body dose equivalents are 3.5 rem, 5.1 rem, and 6.2 rem, respectively. Bone-marrow dose equivalents are only slightly higher than the whole-body estimates in each case. The bone-surface cells (endosteal cells) receive the highest dose, but they are a less sensitive cell population and are less sensitive to fatal cancer induction than whole body and bone marrow. The effective dose equivalents for 30, 50, and 70 y are 3.6 rem, 5.3 rem, and 6.6 rem, respectively. 79 refs., 17 figs., 24 tabs

  17. Doses from radiation exposure

    International Nuclear Information System (INIS)

    Menzel, H-G.; Harrison, J.D.

    2012-01-01

    Practical implementation of the International Commission on Radiological Protection’s (ICRP) system of protection requires the availability of appropriate methods and data. The work of Committee 2 is concerned with the development of reference data and methods for the assessment of internal and external radiation exposure of workers and members of the public. This involves the development of reference biokinetic and dosimetric models, reference anatomical models of the human body, and reference anatomical and physiological data. Following ICRP’s 2007 Recommendations, Committee 2 has focused on the provision of new reference dose coefficients for external and internal exposure. As well as specifying changes to the radiation and tissue weighting factors used in the calculation of protection quantities, the 2007 Recommendations introduced the use of reference anatomical phantoms based on medical imaging data, requiring explicit sex averaging of male and female organ-equivalent doses in the calculation of effective dose. In preparation for the calculation of new dose coefficients, Committee 2 and its task groups have provided updated nuclear decay data (ICRP Publication 107) and adult reference computational phantoms (ICRP Publication 110). New dose coefficients for external exposures of workers are complete (ICRP Publication 116), and work is in progress on a series of reports on internal dose coefficients to workers from inhaled and ingested radionuclides. Reference phantoms for children will also be provided and used in the calculation of dose coefficients for public exposures. Committee 2 also has task groups on exposures to radiation in space and on the use of effective dose.

  18. SU-E-T-196: Comparative Analysis of Surface Dose Measurements Using MOSFET Detector and Dose Predicted by Eclipse - AAA with Varying Dose Calculation Grid Size

    Energy Technology Data Exchange (ETDEWEB)

    Badkul, R; Nejaiman, S; Pokhrel, D; Jiang, H; Kumar, P [University of Kansas Medical Center, Kansas City, KS (United States)

    2015-06-15

    Purpose: Skin dose can be the limiting factor and fairly common reason to interrupt the treatment, especially for treating head-and-neck with Intensity-modulated-radiation-therapy(IMRT) or Volumetrically-modulated - arc-therapy (VMAT) and breast with tangentially-directed-beams. Aim of this study was to investigate accuracy of near-surface dose predicted by Eclipse treatment-planning-system (TPS) using Anisotropic-Analytic Algorithm (AAA)with varying calculation grid-size and comparing with metal-oxide-semiconductor-field-effect-transistors(MOSFETs)measurements for a range of clinical-conditions (open-field,dynamic-wedge, physical-wedge, IMRT,VMAT). Methods: QUASAR™-Body-Phantom was used in this study with oval curved-surfaces to mimic breast, chest wall and head-and-neck sites.A CT-scan was obtained with five radio-opaque markers(ROM) placed on the surface of phantom to mimic the range of incident angles for measurements and dose prediction using 2mm slice thickness.At each ROM, small structure(1mmx2mm) were contoured to obtain mean-doses from TPS.Calculations were performed for open-field,dynamic-wedge,physical-wedge,IMRT and VMAT using Varian-21EX,6&15MV photons using twogrid-sizes:2.5mm and 1mm.Calibration checks were performed to ensure that MOSFETs response were within ±5%.Surface-doses were measured at five locations and compared with TPS calculations. Results: For 6MV: 2.5mm grid-size,mean calculated doses(MCD)were higher by 10%(±7.6),10%(±7.6),20%(±8.5),40%(±7.5),30%(±6.9) and for 1mm grid-size MCD were higher by 0%(±5.7),0%(±4.2),0%(±5.5),1.2%(±5.0),1.1% (±7.8) for open-field,dynamic-wedge,physical-wedge,IMRT,VMAT respectively.For 15MV: 2.5mm grid-size,MCD were higher by 30%(±14.6),30%(±14.6),30%(±14.0),40%(±11.0),30%(±3.5)and for 1mm grid-size MCD were higher by 10% (±10.6), 10%(±9.8),10%(±8.0),30%(±7.8),10%(±3.8) for open-field, dynamic-wedge, physical-wedge, IMRT, VMAT respectively.For 6MV, 86% and 56% of all measured values

  19. Radiation dose electrophysiology procedures

    International Nuclear Information System (INIS)

    Hernandez-Armas, J.; Rodriguez, A.; Catalan, A.; Hernandez Armas, O.; Luque Japon, L.; Moral, S.; Barroso, L.; Rfuez-Hdez, R.

    2006-01-01

    The aim of this paper has been to measure and analyse some of the parameters which are directly related with the doses given to patients in two electrophysiology procedures: diagnosis and ablation with radiofrequency. 16 patients were considered in this study. 13 them had an ablation with radiofrequency at the Unit of Electrophysiology at the University Hospital of the Canaries, La Laguna., Tenerife. The results of skin doses, in the ablation cases, were higher than 2 Gy (threshold of some deterministic effects). The average value was 1.1 Gy. The personal doses, measured under the lead apron, for physician and nurses were 4 and 3 micro Sievert. These results emphasised the necessity of radiation protection measures in order to reduce, ad much as possible, the doses to patients. (Author)

  20. Organ doses from computerized tomography examinations

    Energy Technology Data Exchange (ETDEWEB)

    Janeczek, J.

    1995-12-31

    Estimates of mean organs doses from five typical computerized tomography (CT) examinations were obtained. Measurements were done using Rando-Alderson anthropomorphic phantom and thermoluminescent dosemeters (TLD). Radiation dose distributions within a phantom has been measured for each examination and results were used for organ dose calculation. Doses to organs specified by ICPR 60 Recommendations were measured for five CT scanners (CT/T8800, CT 9800, CT MAX - made by General Electric; CT 1200 SX - made by Picker; SOMATOM 2 - made by Siemens). Dose distributions from scattered radiation were measured and indicate that scattered radiation dose to thyroid and eye lens can be reduced by proper examination limits setting. The lowest mean organ doses were obtained from CT/T8800 scanner. More advanced scanners using high intensity continuous radiation were giving higher organ doses. (author). 23 refs, 6 figs, 13 tabs.

  1. Organ doses from computerized tomography examinations

    International Nuclear Information System (INIS)

    Janeczek, J.

    1995-01-01

    Estimates of mean organs doses from five typical computerized tomography (CT) examinations were obtained. Measurements were done using Rando-Alderson anthropomorphic phantom and thermoluminescent dosemeters (TLD). Radiation dose distributions within a phantom has been measured for each examination and results were used for organ dose calculation. Doses to organs specified by ICPR 60 Recommendations were measured for five CT scanners (CT/T8800, CT 9800, CT MAX - made by General Electric; CT 1200 SX - made by Picker; SOMATOM 2 - made by Siemens). Dose distributions from scattered radiation were measured and indicate that scattered radiation dose to thyroid and eye lens can be reduced by proper examination limits setting. The lowest mean organ doses were obtained from CT/T8800 scanner. More advanced scanners using high intensity continuous radiation were giving higher organ doses. (author). 23 refs, 6 figs, 13 tabs

  2. Impact of Calcium and Two Doses of Vitamin D on Bone Metabolism in the Elderly: A Randomized Controlled Trial.

    Science.gov (United States)

    Rahme, Maya; Sharara, Sima Lynn; Baddoura, Rafic; Habib, Robert H; Halaby, Georges; Arabi, Asma; Singh, Ravinder J; Kassem, Moustapha; Mahfoud, Ziyad; Hoteit, Maha; Daher, Rose T; Bassil, Darina; El Ferkh, Karim; El-Hajj Fuleihan, Ghada

    2017-07-01

    The optimal dose of vitamin D to optimize bone metabolism in the elderly is unclear. We tested the hypothesis that vitamin D, at a dose higher than recommended by the Institute of Medicine (IOM), has a beneficial effect on bone remodeling and mass. In this double-blind trial we randomized 257 overweight elderly subjects to receive 1000 mg of elemental calcium citrate/day, and the daily equivalent of 3750 IU/day or 600 IU/day of vitamin D3 for 1 year. The subjects' mean age was 71 ± 4 years, body mass index 30 ± 4 kg/m 2 , 55% were women, and 222 completed the 12-month follow-up. Mean serum 25 hydroxyvitamin D (25OHD) was 20 ng/mL, and rose to 26 ng/mL in the low-dose arm, and 36 ng/mL in the high-dose arm, at 1 year (p 76 pg/mL showed a trend for higher BMD increments at all skeletal sites, in the high-dose group, that reached significance at the hip. Adverse events were comparable in the two study arms. This controlled trial shows little additional benefit in vitamin D supplementation at a dose exceeding the IOM recommendation of 600 IU/day on BMD and bone markers, in overweight elderly individuals. © 2017 American Society for Bone and Mineral Research. © 2017 American Society for Bone and Mineral Research.

  3. Complete recovery from intractable complex regional pain syndrome, CRPS-type I, following anesthetic ketamine and midazolam.

    Science.gov (United States)

    Kiefer, Ralph-Thomas; Rohr, Peter; Ploppa, Annette; Altemeyer, Karl-Heinz; Schwartzman, Robert Jay

    2007-06-01

    To describe the treatment of an intractable complex regional pain syndrome I (CRPS-I) patient with anesthetic doses of ketamine supplemented with midazolam. A patient presented with a rapidly progressing contiguous spread of CRPS from a severe ligamentous wrist injury. Standard pharmacological and interventional therapy successively failed to halt the spread of CRPS from the wrist to the entire right arm. Her pain was unmanageable with all standard therapy. As a last treatment option, the patient was transferred to the intensive care unit and treated on a compassionate care basis with anesthetic doses of ketamine in gradually increasing (3-5 mg/kg/h) doses in conjunction with midazolam over a period of 5 days. On the second day of the ketamine and midazolam infusion, edema, and discoloration began to resolve and increased spontaneous movement was noted. On day 6, symptoms completely resolved and infusions were tapered. The patient emerged from anesthesia completely free of pain and associated CRPS signs and symptoms. The patient has maintained this complete remission from CRPS for 8 years now. In a patient with severe spreading and refractory CRPS, a complete and long-term remission from CRPS has been obtained utilizing ketamine and midazolam in anesthetic doses. This intensive care procedure has very serious risks but no severe complications occurred. The psychiatric side effects of ketamine were successfully managed with the concomitant use of midazolam and resolved within 1 month of treatment. This case report illustrates the effectiveness and safety of high-dose ketamine in a patient with generalized, refractory CRPS.

  4. Low level dose induced chromosome aberrations in human blood lymphocytes

    International Nuclear Information System (INIS)

    Pohl-Rueling, J.

    1992-01-01

    Unstable structural aberrations in chromosomes of human blood lymphocytes cannot be used as biological dosemeters in the low dose range, when extrapolating from high doses using a linear dose response, as required by the original formula of the dual radiation action theory. A survey is given of experimental dose-response curves of chromosome aberrations, obtained in investigations not only by this institute, in cooperation with many other laboratories, but also by various authors in different areas of the world. The results are not compatible with the predicted linear dose relationships at in vivo dose ranges up to 30 mGy.y -1 . The aberration frequencies rise sharply with dose within the normal environmental exposure up to about twice that level. At higher doses, aberration frequencies increase less rapidly and reach a plateau. Some in vitro experiments of various authors with higher doses of low LET radiations, up to about 400 mGy have found dose responses with steps. (author)

  5. Proximity correction of high-dosed frame with PROXECCO

    Science.gov (United States)

    Eisenmann, Hans; Waas, Thomas; Hartmann, Hans

    1994-05-01

    Usefulness of electron beam lithography is strongly related to the efficiency and quality of methods used for proximity correction. This paper addresses the above issue by proposing an extension to the new proximity correction program PROXECCO. The combination of a framing step with PROXECCO produces a pattern with a very high edge accuracy and still allows usage of the fast correction procedure. Making a frame with a higher dose imitates a fine resolution correction where the coarse part is disregarded. So after handling the high resolution effect by means of framing, an additional coarse correction is still needed. Higher doses have a higher contribution to the proximity effect. This additional proximity effect is taken into account with the help of the multi-dose input of PROXECCO. The dose of the frame is variable, depending on the deposited energy coming from backscattering of the proximity. Simulation proves the very high edge accuracy of the applied method.

  6. The effect of infectious dose on humoral and cellular immune responses in Chlamydophila caviae primary ocular infection.

    Directory of Open Access Journals (Sweden)

    Ana Filipovic

    Full Text Available Following infection, the balance between protective immunity and immunopathology often depends on the initial infectious load. Several studies have investigated the effect of infectious dose; however, the mechanism by which infectious dose affects disease outcomes and the development of a protective immune response is not known. The aim of this study was to investigate how the infectious dose modulates the local and systemic humoral and the cellular immune responses during primary ocular chlamydial infection in the guinea pig animal model. Guinea pigs were infected by ocular instillation of a Chlamydophila caviae-containing eye solution in the conjunctival sac in three different doses: 1×102, 1×104, and 1×106 inclusion forming units (IFUs. Ocular pathology, chlamydial clearance, local and systemic C. caviae-specific humoral and cellular immune responses were assessed. All inocula of C. caviae significantly enhanced the local production of C. caviae-specific IgA in tears, but only guinea pigs infected with the higher doses showed significant changes in C. caviae-specific IgA levels in vaginal washes and serum. On complete resolution of infection, the low dose of C. caviae did not alter the ratio of CD4+ and CD8+ cells within guinea pigs' submandibular lymph node (SMLN lymphocytes while the higher doses increased the percentages of CD4+ and CD8+ cells within the SMLN lymphocytes. A significant negative correlation between pathology intensity and the percentage of CD4+ and CD8+ cells within SMLN lymphocyte pool at selected time points post-infection was recorded for both 1×104, and 1×106 IFU infected guinea pigs. The relevance of the observed dose-dependent differences on the immune response should be further investigated in repeated ocular chlamydial infections.

  7. Gastrointestinal Dose-Histogram Effects in the Context of Dose-Volume–Constrained Prostate Radiation Therapy: Analysis of Data From the RADAR Prostate Radiation Therapy Trial

    Energy Technology Data Exchange (ETDEWEB)

    Ebert, Martin A., E-mail: Martin.Ebert@health.wa.gov.au [Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, Western Australia (Australia); School of Physics, University of Western Australia, Perth, Western Australia (Australia); Foo, Kerwyn [Sydney Medical School, University of Sydney, Sydney, New South Wales (Australia); Haworth, Annette [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne, Victoria (Australia); Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Victoria (Australia); Gulliford, Sarah L. [Joint Department of Physics, Institute of Cancer Research and Royal Marsden National Health Service Foundation Trust, Sutton, Surrey (United Kingdom); Kennedy, Angel [Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, Western Australia (Australia); Joseph, David J. [Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, Western Australia (Australia); School of Surgery, University of Western Australia, Perth, Western Australia (Australia); Denham, James W. [School of Medicine and Public Health, University of Newcastle, Newcastle, New South Wales (Australia)

    2015-03-01

    Purpose: To use a high-quality multicenter trial dataset to determine dose-volume effects for gastrointestinal (GI) toxicity following radiation therapy for prostate carcinoma. Influential dose-volume histogram regions were to be determined as functions of dose, anatomical location, toxicity, and clinical endpoint. Methods and Materials: Planning datasets for 754 participants in the TROG 03.04 RADAR trial were available, with Late Effects of Normal Tissues (LENT) Subjective, Objective, Management, and Analytic (SOMA) toxicity assessment to a median of 72 months. A rank sum method was used to define dose-volume cut-points as near-continuous functions of dose to 3 GI anatomical regions, together with a comprehensive assessment of significance. Univariate and multivariate ordinal regression was used to assess the importance of cut-points at each dose. Results: Dose ranges providing significant cut-points tended to be consistent with those showing significant univariate regression odds-ratios (representing the probability of a unitary increase in toxicity grade per percent relative volume). Ranges of significant cut-points for rectal bleeding validated previously published results. Separation of the lower GI anatomy into complete anorectum, rectum, and anal canal showed the impact of mid-low doses to the anal canal on urgency and tenesmus, completeness of evacuation and stool frequency, and mid-high doses to the anorectum on bleeding and stool frequency. Derived multivariate models emphasized the importance of the high-dose region of the anorectum and rectum for rectal bleeding and mid- to low-dose regions for diarrhea and urgency and tenesmus, and low-to-mid doses to the anal canal for stool frequency, diarrhea, evacuation, and bleeding. Conclusions: Results confirm anatomical dependence of specific GI toxicities. They provide an atlas summarizing dose-histogram effects and derived constraints as functions of anatomical region, dose, toxicity, and endpoint for

  8. Gastrointestinal Dose-Histogram Effects in the Context of Dose-Volume–Constrained Prostate Radiation Therapy: Analysis of Data From the RADAR Prostate Radiation Therapy Trial

    International Nuclear Information System (INIS)

    Ebert, Martin A.; Foo, Kerwyn; Haworth, Annette; Gulliford, Sarah L.; Kennedy, Angel; Joseph, David J.; Denham, James W.

    2015-01-01

    Purpose: To use a high-quality multicenter trial dataset to determine dose-volume effects for gastrointestinal (GI) toxicity following radiation therapy for prostate carcinoma. Influential dose-volume histogram regions were to be determined as functions of dose, anatomical location, toxicity, and clinical endpoint. Methods and Materials: Planning datasets for 754 participants in the TROG 03.04 RADAR trial were available, with Late Effects of Normal Tissues (LENT) Subjective, Objective, Management, and Analytic (SOMA) toxicity assessment to a median of 72 months. A rank sum method was used to define dose-volume cut-points as near-continuous functions of dose to 3 GI anatomical regions, together with a comprehensive assessment of significance. Univariate and multivariate ordinal regression was used to assess the importance of cut-points at each dose. Results: Dose ranges providing significant cut-points tended to be consistent with those showing significant univariate regression odds-ratios (representing the probability of a unitary increase in toxicity grade per percent relative volume). Ranges of significant cut-points for rectal bleeding validated previously published results. Separation of the lower GI anatomy into complete anorectum, rectum, and anal canal showed the impact of mid-low doses to the anal canal on urgency and tenesmus, completeness of evacuation and stool frequency, and mid-high doses to the anorectum on bleeding and stool frequency. Derived multivariate models emphasized the importance of the high-dose region of the anorectum and rectum for rectal bleeding and mid- to low-dose regions for diarrhea and urgency and tenesmus, and low-to-mid doses to the anal canal for stool frequency, diarrhea, evacuation, and bleeding. Conclusions: Results confirm anatomical dependence of specific GI toxicities. They provide an atlas summarizing dose-histogram effects and derived constraints as functions of anatomical region, dose, toxicity, and endpoint for

  9. Dose Recalculation and the Dose-Guided Radiation Therapy (DGRT) Process Using Megavoltage Cone-Beam CT

    International Nuclear Information System (INIS)

    Cheung, Joey; Aubry, Jean-Francois; Yom, Sue S.; Gottschalk, Alexander R.; Celi, Juan Carlos; Pouliot, Jean

    2009-01-01

    Purpose: At University of California San Francisco, daily or weekly three-dimensional images of patients in treatment position are acquired for image-guided radiation therapy. These images can be used for calculating the actual dose delivered to the patient during treatment. In this article, we present the process of performing dose recalculation on megavoltage cone-beam computed tomography images and discuss possible strategies for dose-guided radiation therapy (DGRT). Materials and Methods: A dedicated workstation has been developed to incorporate the necessary elements of DGRT. Patient image correction (cupping, missing data artifacts), calibration, completion, recontouring, and dose recalculation are all implemented in the workstation. Tools for dose comparison are also included. Examples of image correction and dose analysis using 6 head-and-neck and 2 prostate patient datasets are presented to show possible tracking of interfraction dosimetric endpoint variation over the course of treatment. Results: Analysis of the head-and-neck datasets shows that interfraction treatment doses vary compared with the planning dose for the organs at risk, with the mean parotid dose and spinal cord D 1 increasing by as much as 52% and 10%, respectively. Variation of the coverage to the target volumes was small, with an average D 5 dose difference of 1%. The prostate patient datasets revealed accurate dose coverage to the targeted prostate and varying interfraction dose distributions to the organs at risk. Conclusions: An effective workflow for the clinical implementation of DGRT has been established. With these techniques in place, future clinical developments in adaptive radiation therapy through daily or weekly dosimetric measurements of treatment day images are possible.

  10. Absorbed doses to patients from angioradiology

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Romero, R; Hernandez-Armas, J [Servicio de Fisica Medica, Hospital Universitario de Canarias, La Laguna, Tenerife (Spain); Diaz-Romero, F [Servicio de Radiodiagnostico, Hospital Universitario de Canarias, La Laguna, Tenerife (Spain)

    2001-03-01

    The aim of study was to know patients doses exposes when three different procedures of angioradiology were carried out. The explorations considered were drainage biliary, varicocele embolization and dacriocistography made in the Radiodiagnostic Service at the University Hospital of Canary Islands, Tenerife (Spain). In total 14 patients were studied. The measurements were made using large area transmission ionisation chamber which gives the values of Dose Area Product (DAP). In addition, thermoluminescent dosimeters type TLD-100 were used in anthropomorphic phantom in order to obtain values of organ doses when the phantom was submitted to the same procedures rather than the actual patients. Furthermore, the Effdose program was used to estimate the effective doses in the procedures conditions. The values for DAP were in the range of 70-300 for drainage biliary, 43-180 for varicocele embolization and 1.4-9 for dacriocistography. The organ doses measured with TLD-100 were higher than the corresponding values estimated by Effdose program. The results for varicocele embolization were higher than other published data. In the case of drainage biliary procedure, the values were closed to other published results. It was not possible to find data for dacriocistography from other authors. (author)

  11. Absorbed doses to patients from angioradiology

    International Nuclear Information System (INIS)

    Rodriguez-Romero, R.; Hernandez-Armas, J.; Diaz-Romero, F.

    2001-01-01

    The aim of study was to know patients doses exposes when three different procedures of angioradiology were carried out. The explorations considered were drainage biliary, varicocele embolization and dacriocistography made in the Radiodiagnostic Service at the University Hospital of Canary Islands, Tenerife (Spain). In total 14 patients were studied. The measurements were made using large area transmission ionisation chamber which gives the values of Dose Area Product (DAP). In addition, thermoluminescent dosimeters type TLD-100 were used in anthropomorphic phantom in order to obtain values of organ doses when the phantom was submitted to the same procedures rather than the actual patients. Furthermore, the Effdose program was used to estimate the effective doses in the procedures conditions. The values for DAP were in the range of 70-300 for drainage biliary, 43-180 for varicocele embolization and 1.4-9 for dacriocistography. The organ doses measured with TLD-100 were higher than the corresponding values estimated by Effdose program. The results for varicocele embolization were higher than other published data. In the case of drainage biliary procedure, the values were closed to other published results. It was not possible to find data for dacriocistography from other authors. (author)

  12. Effects of high dose coffee intake on aerobic power in dragon female athletes

    Directory of Open Access Journals (Sweden)

    Shabani Ramin

    2016-08-01

    Full Text Available Background : There are few studies that consider the effect of high doses of caffeine on aerobic power (VO2max. Also, to date, no study examined the effect of coffee intake on dragon boat paddler specifically on women. The purpose of this study was to investigate the effect of espresso coffee on improvement of aerobic power of dragon boat paddler. Material : Twenty women athletes of Guilan dragon bout team members of Malavan club of port city of Anzali (mean ±SD age, 23.60± 3.49 years; BMI,23.77±1.88kg/m2; body fat, 30.32±4.65% were recruited to this study, after they completed a primary test without consuming any coffee, they consumed 6mg/kg of coffee (espresso or decaffeinated and following that they completed two experimental trials. A randomized, double-blind, repeated-measures, design was employed whereby paddlers complete a 2000m paddling dragon boat ergo-meter. Results : Coffee could improve VO2max (Without coffee =74.40± QUOTE 4.99, Espresso coffee =90.10± QUOTE 6.19, Decaffeinated coffee =91.00± QUOTE 5.67, P≤ QUOTE 0.05. VO2max amount after exercise were significantly higher for both espresso coffee and decaffeinated coffee, when compared with without coffee condition. No significant differences were observed between espresso coffee and decaffeinated coffee (P≤ QUOTE 0.05. Conclusion : The present study shows that both high doses of caffeine (espresso coffee and decaffeinated coffee can enhance VO2max during aerobic exercise including 2000m dragon boat paddling. It seems that some compounds except caffeine in decaffeinated coffee can act improve VO2max. Further studies needed for considering the effect of high doses of coffee on endurance exercises. Also in other age ranges of women athletes and other sport athletes.

  13. Long-term outcome of lobar ablation in differentiated thyroid cancer (DTC): a comparative study with patients of completion thyroidectomy

    International Nuclear Information System (INIS)

    Santra, Amburanjan; Maharjan, S.; Bal, C.

    2010-01-01

    Full text: Completion thyroidectomy (CT) is usually recommended after partial surgery in patients with differentiated thyroid cancer. Radioiodine lobar ablation (RAILA) is an easy alternative and avoids complications that might be associated with re-surgery. But its effectiveness in terms of long-term outcome and recurrence free survival is yet to be established. This study was aimed to compare long term outcome of RAILA with that of completion thyroidectomy. Materials and Methods: A retrospective analysis was done from the case records of patients treated in our thyroid clinic for last 25 years. Records of all patients of RAILA (364) and CT (372) were analyzed. Complete ablation rate, cumulative dose needed for complete ablation, Recurrence rate and recurrence free survival was estimated in each group. Comparison was made between two groups by statistical method. Results: There was 73% ablation rate at 1st dose of RAILA itself. Second dose in LA and first dose of remnant ablation after CT is comparable (92% and 93% respectively). Cumulative dose to achieve 100% ablation rate is more for RAILA group. Seven patients developed recurrence in RAILA group, compared to 14 in CT group. No statistically significant difference was noted between recurrence rate and recurrence free survival between two groups. Conclusion: Radioiodine Lobar ablation is a safe, effective and less costly alternative to completion thyroidectomy in patients with differentiated thyroid cancer with comparable long term outcome like recurrence rate and recurrence free survival

  14. A randomized dose-response trial of aerobic exercise and health-related quality of life in colon cancer survivors.

    Science.gov (United States)

    Brown, Justin C; Damjanov, Nevena; Courneya, Kerry S; Troxel, Andrea B; Zemel, Babette S; Rickels, Michael R; Ky, Bonnie; Rhim, Andrew D; Rustgi, Anil K; Schmitz, Kathryn H

    2018-04-01

    To examine the dose-response effects of aerobic exercise on health-related quality of life (HRQoL) among colon cancer survivors. Thirty-nine stage I to III colon cancer survivors were randomized to 1 of 3 groups: usual-care control, 150 min·wk -1 of aerobic exercise (low-dose) and 300 min·wk -1 of aerobic exercise (high-dose) for 6 months. HRQoL outcomes included the Short Form (SF)-36 physical and mental component summary, Functional Assessment of Cancer Therapy-Colorectal, Pittsburgh Sleep Quality Index, Fear of Cancer Recurrence Inventory, Fatigue Symptom Inventory, and North Central Cancer Treatment Group bowel function questionnaire, assessed at baseline and post intervention. The primary hypothesis was that exercise would improve HRQoL outcomes in a dose-response fashion, such that high-dose aerobic exercise would yield the largest improvements in HRQoL outcomes. Over 6 months, the low-dose group completed 141 ± 10 min·wk -1 of aerobic exercise, and the high-dose group completed 247 ± 11 min·wk -1 of aerobic exercise. Over 6 months, exercise improved the physical component summary score of the SF-36 (P trend  = 0.002), the Functional Assessment of Cancer Therapy-Colorectal (P trend  = 0.025), the Pittsburgh Sleep Quality Index (P trend  = 0.049), and the Fatigue Symptom Inventory (P trend  = 0.045) in a dose-response fashion. Between-group standardized mean difference effects sizes for the above-described findings were small to moderate in magnitude (0.35-0.75). No dose-response effects were observed for the mental component summary score of the SF-36, the Fear of Cancer Recurrence Inventory, or bowel function. Higher doses of aerobic exercise, up to 300 min·wk -1 , improve multiple HRQoL outcomes among stage I to III colon cancer survivors. These findings provide evidence that aerobic exercise may provide multiple health benefits for colon cancer survivors. Copyright © 2018 John Wiley & Sons, Ltd.

  15. Mammography dose in relation to body mass index, race, and menopausal status

    Energy Technology Data Exchange (ETDEWEB)

    Schubauer-Berigan, M.K.; Frey, G.D.; Baron, L.; Hoel, D.G

    2002-07-01

    Mammography dose increases with compressed breast thickness (CBT), but few studies have examined other correlates of dose. The purpose of this study was to evaluate the relation between factors such as race, age, body mass index (BMI), CBT, and menopausal status and mammography screening dose, measured for 509 women in a US population. A multiple linear regression model was developed for dose, based on consideration of these factors as well as examination characteristics. BMI and number of films during examination were positively related to dose. After adjusting for these factors, high CBT also leads to higher dose. Whites receive lower doses than black women, but differences are slight after controlling for the effects of CBT and BMI, which were significantly higher among black women. Pre-menopausal women receive higher doses, after adjusting for all other factors, than post-menopausal women. Jointly, these factors account for approximately 75% to 80% of the variability in dose among this study population. Because rates of overweight are increasing in the US, average doses from mammography may be increasing as well. (author)

  16. Mammography dose in relation to body mass index, race, and menopausal status

    International Nuclear Information System (INIS)

    Schubauer-Berigan, M.K.; Frey, G.D.; Baron, L.; Hoel, D.G.

    2002-01-01

    Mammography dose increases with compressed breast thickness (CBT), but few studies have examined other correlates of dose. The purpose of this study was to evaluate the relation between factors such as race, age, body mass index (BMI), CBT, and menopausal status and mammography screening dose, measured for 509 women in a US population. A multiple linear regression model was developed for dose, based on consideration of these factors as well as examination characteristics. BMI and number of films during examination were positively related to dose. After adjusting for these factors, high CBT also leads to higher dose. Whites receive lower doses than black women, but differences are slight after controlling for the effects of CBT and BMI, which were significantly higher among black women. Pre-menopausal women receive higher doses, after adjusting for all other factors, than post-menopausal women. Jointly, these factors account for approximately 75% to 80% of the variability in dose among this study population. Because rates of overweight are increasing in the US, average doses from mammography may be increasing as well. (author)

  17. High-dose preoperative radiation for cancer of the rectum: Impact of radiation dose on patterns of failure and survival

    International Nuclear Information System (INIS)

    Ahmad, N.R.; Mohiuddin, M.; Marks, G.

    1993-01-01

    A variety of dose-time schedules are currently used for preoperative radiation therapy of rectal cancer. An analysis of patients treated with high-dose preoperative radiation therapy was undertaken to determine the influence of radiation dose on the patterns of failure, survival, and complications. Two hundred seventy-five patients with localized rectal cancer were treated with high-dose preoperative radiation therapy. One hundred fifty-six patients received 45 Gy (low-dose group). Since 1985, 119 patients with clinically unfavorable cancers were given a higher dose, 55 Gy using a shrinking field technique (high-dose group). All patients underwent curative resection. Median follow-up was 66 months in the low-dose group and 28 months in the high-dose group. Patterns of failure, survival, and complications were analyzed as a function of radiation dose. Fourteen percent of the total group developed a local recurrence; 20% in the low-dose group as compared with 6% in the high-dose group. The actuarial local recurrence rate at 5 years was 20% for the low-dose group and 8% for the high-dose group, and approached statistical significance with p = .057. For tethered/fixed tumors the actuarial local recurrence rates at 5 years were 28% and 9%, respectively, with p = .05. Similarly, for low-lying tumors (less than 6 cm from the anorectal junction) the rates were 24% and 9%, respectively, with p = .04. The actuarial rate of distant metastasis was 28% in the low-dose group and 20% in the high-dose group and was not significantly different. Overall actuarial 5-year survival for the total group of patients was 66%. No significant difference in survival was observed between the two groups, despite the higher proportion of unfavorable cancers in the high-dose group. The incidence of complications was 2%, equally distributed between the two groups. High-dose preoperative radiation therapy for rectal cancer results in excellent local control rates. 27 refs., 2 figs., 8 tabs

  18. Intracavitary radiation treatment planning and dose evaluation

    International Nuclear Information System (INIS)

    Anderson, L.L.; Masterson, M.E.; Nori, D.

    1987-01-01

    Intracavitary radiation therapy with encapsulated radionuclide sources has generally involved, since the advent of afterloading techniques, inserting the sources in tubing previously positioned within a body cavity near the region to be treated. Because of the constraints on source locations relative to the target region, the functions of treatment planning and dose evaluation, usually clearly separable in interstitial brachytherapy, tend to merge in intracavitary therapy. Dose evaluation is typically performed for multiple source-strength configurations in the process of planning and thus may be regarded as complete when a particular configuration has been selected. The input data for each dose evaluation, of course, must include reliable dose distribution information for the source-applicator combinations used. Ultimately, the goal is to discover the source-strength configuration that results in the closest possible approach to the dose distribution desired

  19. Reducing dose in paediatric CT: a preliminary study of radiographers' knowledge

    International Nuclear Information System (INIS)

    Heagney, J.; Lewis, S.; Chaffey, C.; Howlett, G.; Moran, A.; McLean, D.

    2003-01-01

    The objective of this study is to evaluate the responses of Australian radiographers in comparison with current literature on paediatric protocols and scanning recommendations in order to determine how and if paediatric Computed Tomography (CT) exposure reductions are taking place within Medical Imaging Departments. Subjects and Methods: The method involved a dual format; consisting of surveying 30 CT radiographers, and additionally, interviewing 5 senior CT radiographers. Of the 30 surveys completed, one was completed by a PDY radiographer, 7 by CT Senior radiographers and 22 by CT radiographers. The survey contained a range of questions about appropriate paediatric CT scanning parameters and protocols. Five CT Seniors were interviewed to ascertain the current level and opinion of training in paediatric protocols, in-house educational programs and the implementation of radiation dose saving parameters. Radiographers demonstrated reasonable ability to identify suitable paediatric protocols and believed the in-house CT protocols resident to their medical imaging department to be adequate, despite many utilising exposures higher than those from recommended literature. The interviews revealed that no further training in CT paediatric dose reduction was currently available, however survey responses indicated that further training would be beneficial. This study demonstrates that radiographers are aware of the need to reduce exposure parameters for paediatric CT and tend to follow protocols in place within their workplace, regardless of suitability and patient needs. Copyright (2003) Australian Institute of Radiography

  20. Reducing dose in paediatric CT: a preliminary study of radiographers' Knowledge

    International Nuclear Information System (INIS)

    Heagney, Jillian; Lewis, Sarah; Chaffey, Clare; Howlett, Genevieve; Moran, Alexander; McLean, Donald

    2003-01-01

    The objective of this study is to evaluate the responses of Australian radiographers in comparison with current literature on paediatric protocols and scanning recommendations in order to determine how and if paediatric Computed Tomography (CT) exposure reductions are taking place within Medical Imaging Departments. Subjects and Methods: The method involved a dual format; consisting of surveying 30 CT radiographers, and additionally, interviewing 5 senior CT radiographers. Of the 30 surveys completed, one was completed by a PDY radiographer, 7 by CT Senior radiographers and 22 by CT radiographers. The survey contained a range of questions about appropriate paediatric CT scanning parameters and protocols. Five CT Seniors were interviewed to ascertain the current level and opinion of training in paediatric protocols, in-house educational programs and the implementation of radiation dose saving parameters. Radiographers demonstrated reasonable ability to identify suitable paediatric protocols and believed the in-house CT protocols resident to their medical imaging department to be adequate, despite many utilising exposures higher than those from recommended literature. The interviews revealed that no further training in CT paediatric dose reduction was currently available, however survey responses indicated that further training would be beneficial. This study demonstrates that radiographers are aware of the need to reduce exposure parameters for paediatric CT and tend to follow protocols in place within their workplace, regardless of suitability and patient needs Copyright (2003) Australian Institute of Radiography

  1. Complete release from regulatory control via the density of radioactive contamination of soil of the Chornobyl exclusion zone

    International Nuclear Information System (INIS)

    Bondarenko, Oleg; Fadeev, Mykhaylo; Kireev, Serhiy; Proskura, Mykola

    2008-01-01

    Full text: In this work a general procedure of establishment the criterion of complete release from regulatory control via the density of radioactive contamination of soil of alone areas of the Chornobyl exclusion zone is represented by the following three stages, namely: 1) Justification of the dose criterion of complete release by applying the fundamental approaches of regulating the prolonged exposure of the public on a basement of ICRP Publication No. 82; 2) Justification of a procedure for establishment of dose constraint through evaluation of the statistical distribution of a controlled radiation value through determination of the high boundary of the confidence interval; 3) Generalization of conversion coefficients (via the density of radioactive contamination of soil) and coverage coefficients for the dose forming factors of the public (inhalation intake of transuranium radionuclides both at natural and technogenic dust resuspension, peroral intake of 137 Cs and 90 Sr via food stuff, external exposure from 137 Cs); on a basis of these coefficients average doses and dose constraint of a critical group of the public are calculated. As it is shown in the work, the generalized criterion of complete release from regulatory control via the density of radioactive contamination of soil of the Chornobyl exclusion zone can be defined by dividing the recommended ICRP dose clearance level for situation of the post-accidental prolonged exposure of a critical group of the public, namely, 0.3 mSv·year -1 to the dose conversion coefficient (i.e. transfer from the superficial soil contamination of radioactivity to the dose constraint for the Chornobyl exclusion zone), namely, 12.9 μSv·year -1 /((kBq·M -2 ). Thus, a level of the density of radioactive contamination of soil, that provides the complete release from regulatory control makes 23.3 kBq·M -2 . For completion of the work on justification of the criterion of complete territory release in the conditions of

  2. Influence of dose history on thermoluminescence response of Ge-doped silica optical fibre dosimeters

    International Nuclear Information System (INIS)

    Moradi, F.; Mahdiraji, G.A.; Dermosesian, E.; Khandaker, M.U.; Ung, N.M.; Mahamd Adikan, F.R.; Amin, Y.M.

    2017-01-01

    Nowadays, silica based optical fibres show enough potential to be used as TL dosimeters in different applications. Reuse of optical fibre as a practical dosimeter demands to complete removal of accumulated doses via previous irradiations. This work investigates the existence and/or effect of remnant doses in fibre dosimeter from the previous irradiations, and proposes a method to control this artifact. A single mode Ge-doped optical fibre is used as TL radiation sensor, while a well calibrated Gammacell with 60 Co source is used for irradiations. The effect of irradiation history on the TL response of optical fibres is surveyed extensively for doses ranged from 1 to 1000 Gy. The results show that the absorbed dose history in a fibre affects its response in the next irradiation cycles. It is shown that a dose history of around 100 Gy can increase the response of optical fibre by a factor of 1.72. The effect of annealing at higher temperatures on stabilizing the fibre response is also examined and results revealed that another alteration in the structure of trapping states occurs in glass medium which can change the sensitivity of fibres. Preservation of the sensitivity during successive irradiation cycles can be achieved by a proper annealing procedure accompanied by a pre-dose treatment. - Highlights: • Influence of dose history on TL characteristics of fibre dosimeter is explored. • The phenomenon behind the TL variation caused by dose history is discussed. • Effect of annealing temperature on performance of fibre dosimeter is studied. • Pre-treatment methods for mitigating variation in reproducibility are proposed.

  3. Dose-rate effects in synchronous mammalian cells in culture. II. A comparison of the life cycle of HeLa cells during continuous irradiation or multiple-dose fractionation

    International Nuclear Information System (INIS)

    Mitchell, J.B.; Bedford, J.S.

    1977-01-01

    The life cycle of synchronized S3 HeLa cells was examined during continuous irradiation at a dose rate of approximately 37 rad/hr and during multiple dose fractionation schedules of the same average dose rate (total dose / overall time = average dose rate). For all regimes given at this dose rate the effects on the life cyclee were similar. Cells progressed through G1 and S without appreciable delay and experienced a minimum G2 delay of about 10 hr. Cells eventually entered mitosis but virtually none were able to complete a successful division

  4. Single-dose radiotherapy for painful bone metastases

    International Nuclear Information System (INIS)

    Kal, H.B.

    1999-01-01

    Background: External beam radiotherapy is frequently applied for palliative treatment of painful bone lesions with a variety of fractionation schemes. There is a continuous interest to administer only 1 or a few dose fractions for inducing pain relief. Methods: A review of the literature was made with the aim to determine whether a treatment can be deduced that is simple and effective. The linear-quadratic (L-Q) concept was applied to compare reported therapy schemes which each other for the iso-effect pain relief. Results: Single-dose and fractionated radiotherapy resulted in partial or complete pain relief in about 80% of the patients. Complete responses have been observed in about 43% of the patients. For patients responding to treatment, the duration of pain relief is at least 3 to 4 months with reported duration of up to 1 year or even longer. Conclusion: Based on this review of literature data concerning randomized trials a treatment with a single dose of 8 Gy is effective for inducing pain relief. (orig.) [de

  5. Radiobiological modelling of dose-gradient effects in low dose rate, high dose rate and pulsed brachytherapy

    International Nuclear Information System (INIS)

    Armpilia, C; Dale, R G; Sandilos, P; Vlachos, L

    2006-01-01

    This paper presents a generalization of a previously published methodology which quantified the radiobiological consequences of dose-gradient effects in brachytherapy applications. The methodology uses the linear-quadratic (LQ) formulation to identify an equivalent biologically effective dose (BED eq ) which, if applied uniformly to a specified tissue volume, would produce the same net cell survival as that achieved by a given non-uniform brachytherapy application. Multiplying factors (MFs), which enable the equivalent BED for an enclosed volume to be estimated from the BED calculated at the dose reference surface, have been calculated and tabulated for both spherical and cylindrical geometries. The main types of brachytherapy (high dose rate (HDR), low dose rate (LDR) and pulsed (PB)) have been examined for a range of radiobiological parameters/dimensions. Equivalent BEDs are consistently higher than the BEDs calculated at the reference surface by an amount which depends on the treatment prescription (magnitude of the prescribed dose) at the reference point. MFs are closely related to the numerical BED values, irrespective of how the original BED was attained (e.g., via HDR, LDR or PB). Thus, an average MF can be used for a given prescribed BED as it will be largely independent of the assumed radiobiological parameters (radiosensitivity and α/β) and standardized look-up tables may be applicable to all types of brachytherapy treatment. This analysis opens the way to more systematic approaches for correlating physical and biological effects in several types of brachytherapy and for the improved quantitative assessment and ranking of clinical treatments which involve a brachytherapy component

  6. Technical feasibility proof for high-resolution low-dose photon-counting CT of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Kalender, Willi A.; Kolditz, Daniel; Lueck, Ferdinand [University of Erlangen-Nuernberg, Institute of Medical Physics (IMP), Erlangen (Germany); CT Imaging GmbH, Erlangen (Germany); Steiding, Christian [University of Erlangen-Nuernberg, Institute of Medical Physics (IMP), Erlangen (Germany); CT Imaging GmbH, Erlangen (Germany); University Hospital of Erlangen, Institute of Radiology, Erlangen (Germany); Ruth, Veikko; Roessler, Ann-Christin [University of Erlangen-Nuernberg, Institute of Medical Physics (IMP), Erlangen (Germany); Wenkel, Evelyn [University Hospital of Erlangen, Institute of Radiology, Erlangen (Germany)

    2017-03-15

    X-ray computed tomography (CT) has been proposed and evaluated multiple times as a potentially alternative method for breast imaging. All efforts shown so far have been criticized and partly disapproved because of their limited spatial resolution and higher patient dose when compared to mammography. Our concept for a dedicated breast CT (BCT) scanner therefore aimed at novel apparatus and detector design to provide high spatial resolution of about 100 μm and average glandular dose (AGD) levels of 5 mGy or below. Photon-counting technology was considered as a solution to reach these goals. The complete concept was previously evaluated and confirmed by simulations and basic experiments on laboratory setups. We here present measurements of dose, technical image quality parameters and surgical specimen results on such a scanner. For comparison purposes, the specimens were also imaged with digital mammography (DM) and breast tomosynthesis (BT) apparatus. Results show that photon-counting BCT (pcBCT) at 5 mGy AGD offers sufficiently high 3D spatial resolution for reliable detectability of calcifications and soft tissue delineation. (orig.)

  7. Patient and staff doses in interventional neuroradiology

    International Nuclear Information System (INIS)

    Bor, D.; Cekirge, S.; Tuerkay, T.; Turan, O.; Guelay, M.; Oenal, E.; Cil, B.

    2005-01-01

    Radiation doses for interventional examinations are generally high and therefore necessitate dose monitoring for patients and staff. Relating the staff dose to a patient dose index, such as dose-area product (DAP), could be quite useful for dose comparisons. In this study, DAP and skin doses of 57 patients, who underwent neuro-interventional examinations, were measured simultaneously with staff doses. Although skin doses were comparable with the literature data, higher DAP values of 215 and 188.6 Gy cm 2 were measured for the therapeutical cerebral and carotid examinations, respectively, owing to the use of biplane system and complexity of the procedure. Mean staff doses for eye, finger and thyroid were measured as 80.6, 77.6 and 28.8 μGy per procedure. The mean effective dose per procedure for the radiologists was 32 μSv. In order to allow better comparisons to be made, DAP normalised doses were also presented. (authors)

  8. Estimation of patient dose in abdominal CT examination in some Sudanese hospitals

    International Nuclear Information System (INIS)

    Adam, Ebthal Adam Shikhalden

    2016-04-01

    The use of CT in medical diagnosis delivers radiation doses to patients that are higher than those from other radiological procedures. The aim of this study was to estimate radiation doses in abdomen CT examinations of patients in two Sudanese hospitals. Details were obtained from approximately 80 CT examinations and included all age groups ( adults and pediatric). The results from the two hospitals were compared with each other as well as with the IAEA guidance level for this particular investigation. The estimation of radiation doses were carried out by calculating volume dose index (CTD1vol), dose length product (DLP), doses to some organs of interest and effective dose (E) using the software program "CT EXPO V2.1". The study showed that the mean DLP of the one hospitals ASH is 1736.7 mGy.cm which is by far much higher than that for the other hospital NMDC which stands at 185.3 mGy.cm, as well as higher than the IAEA level which is 696 mGy.cm. The study showed that the mean CTD1vol for patients in ASH is 36.2 mGy which again higher than that for the other hospital which is 3.9 mGy and higher than the IAEA level which is 10.9 mGy calculating the effective dose for patients in the two hospitals reveals that the mean effective dose of patient in one hospital (ASH) is 26.25 mSv, which is quite high compared with other hospital (NMDC), which has the mean value of 2.8 mGv and also higher than the IAEA level from this investigation which is 7.6 mSv. Regarding organ doses, the study showed that organ doses in hospital ASH are always higher than that calculated in hospital NMDC and the highest doses in both hospital were delivered to the kidneys with mean values of 50.24 mGy and 5045 mGy for the two hospitals respectively. The study showed that there is an urgent need for optimizing patient doses in such CT examinations. This can be ensured by providing training and retraining for workers and conducting quality control measurements and preventive maintenance regularly so

  9. Maximal safe dose therapy of I-131 after failure of standard fixed dose therapy in patients with differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Lee, Jong Jin; Seok, Ju Won; Uh, Jae Sun

    2005-01-01

    In patients with recurrent or metastatic differentiated thyroid carcinoma, residual disease despite repetitive fixed dose I-131 therapy presents an awkward situation in terms of treatment decision making. Maximal safe dose (MSD) administration base on bone marrow radiation allows the delivery of a large amount I-131 to thyroid cancer tissue within the safety margin. We investigated the efficacy of MSD in differentiated thyroid cancers, which had persisted after conventional fixed dose therapy. Forty-six patients with differentiated thyroid carcinoma who had non-responsible residual disease despite repetitive fixed dose I-131 therapy were enrolled in this study. The postoperative pathology consisted of 43 papillary carcinomas and 3 follicular carcinomas. MSD was calculated according the Memorial Sloan Kettering Cancer Center protocol using blood samples. MSDs were administered at intervals of at least 6 months. Treatment responses were evaluated using I-131 whole body scan (WBS) and serum thyroglobulin measurements. Mean calculated MSD was 12.5±2.1 GBq. Of the 46 patients, 6 (13.0%) showed complete remission, 15 (32.6%) partial response, 19 (41.3%) stable disease, and 6 (13.0%) disease progression. Thus, about a half of the patients showed complete or partial remission, and of these patients, 14 (67%) showed response after a single MSD administration and 6 (29%) showed response after the second dose of MSD administrations. Twenty-nine patients (63%) experienced transient cytopenia after therapy, and recovered spontaneously with the exception of one. MSD administration is an effective method even in the patients who failed to be treated by conventional fixed dose therapy. MSD therapy of I-131 can be considered in the patients who failed by fixed dose therapy

  10. Radiation doses in buildings containing coal

    International Nuclear Information System (INIS)

    Somlai, J.; Kanyar, B.; Nenyei, A.; Nemeth, Z.; Nemeth, Cs.

    2001-01-01

    Using coal-slag with high concentration of 226 Ra as building material could result excess dose of people living in these dwellings. The gamma dose rate, the radon concentration and the radionuclide concentration of built-in slags were measured in kindergartens, schools and homes of three towns (Ajka, Tatabanya, Varpalota). The absorbed dose rates exceeded significantly the world average (80 nGy/h) and the annual dose reached 3-4 mSv in some cases. The dose coming from radon is significant in the case of slags, which did not originate from power plants but from smaller stoves and furnaces because in these cases the burning temperature is lower, so the radon emanation is higher. The dose in the latter cases could reach 10-20 mSv/year. (author)

  11. Intermediate doses of rituximab used as adjuvant therapy in refractory pemphigus

    Directory of Open Access Journals (Sweden)

    Pradnya J Londhe

    2014-01-01

    Full Text Available Background: Rituximab, a monoclonal anti-CD20 antibody, has been used with encouraging results in pemphigus. We describe herein refractory cases of pemphigus vulgaris (n = 23 and pemphigus foliaceus (n = 1 treated with rituximab in addition to steroids and immunosuppressants. Aims: To assess the response to treatment, the duration of clinical remission, serology of the response and adverse effects of rituximab in pemphigus patients. Methods: We recorded observations of 24 patients with pemphigus having either refractory disease in spite of high dose of steroids and immunosuppressants, corticosteroid-dependent disease, strong contraindications to corticosteroids, or severe disease. The patients were treated with infusions of one injection per week for three consecutive weeks of 375 mg of rituximab per m 2 of body-surface area. One similar infusion was repeated after 3 months of 3 rd dose. We observed the clinical outcome after 6 months of 3 rd dose of rituximab and looked for complete healing of cutaneous and mucosal lesions (complete remission. Observations: After follow-up of 7-24 months, five patients showed only partial improvement while 19 of 24 patients had a complete remission 3 months after rituximab. Of these 19 patients, 12 patients achieved complete remission and are off all systemic therapy, and the rest are continuing with no or low dose of steroids with immunosuppressants. Two patients relapsed after initial improvement; one was given moderate dose of oral steroids and immunosuppressant and the other was given repeat single dose of rituximab to control relapse. Conclusion: Rituximab is able to induce a prolonged clinical remission in pemphigus after a single course of four infusions. The high cost and limited knowledge of long term adverse effects are limitations to the use of this biologic agent.

  12. The IR obstruction to UV completion for Dante’s Inferno model with higher-dimensional gauge theory origin

    Energy Technology Data Exchange (ETDEWEB)

    Furuuchi, Kazuyuki [Manipal Centre for Natural Sciences, Manipal University,Manipal, Karnataka 576104 (India); Koyama, Yoji [National Center for Theoretical Sciences, National Tsing-Hua University,Hsinchu 30013, Taiwan R.O.C. (China)

    2016-06-21

    We continue our investigation of large field inflation models obtained from higher-dimensional gauge theories, initiated in our previous study http://dx.doi.org/10.1088/1475-7516/2015/02/031. We focus on Dante’s Inferno model which was the most preferred model in our previous analysis. We point out the relevance of the IR obstruction to UV completion, which constrains the form of the potential of the massive vector field, under the current observational upper bound on the tensor to scalar ratio. We also show that in simple examples of the potential arising from DBI action of a D5-brane and that of an NS5-brane that the inflation takes place in the field range which is within the convergence radius of the Taylor expansion. This is in contrast to the well known examples of axion monodromy inflation where inflaton takes place outside the convergence radius of the Taylor expansion. This difference arises from the very essence of Dante’s Inferno model that the effective inflaton potential is stretched in the inflaton field direction compared with the potential for the original field.

  13. The IR obstruction to UV completion for Dante’s Inferno model with higher-dimensional gauge theory origin

    International Nuclear Information System (INIS)

    Furuuchi, Kazuyuki; Koyama, Yoji

    2016-01-01

    We continue our investigation of large field inflation models obtained from higher-dimensional gauge theories, initiated in our previous study http://dx.doi.org/10.1088/1475-7516/2015/02/031. We focus on Dante’s Inferno model which was the most preferred model in our previous analysis. We point out the relevance of the IR obstruction to UV completion, which constrains the form of the potential of the massive vector field, under the current observational upper bound on the tensor to scalar ratio. We also show that in simple examples of the potential arising from DBI action of a D5-brane and that of an NS5-brane that the inflation takes place in the field range which is within the convergence radius of the Taylor expansion. This is in contrast to the well known examples of axion monodromy inflation where inflaton takes place outside the convergence radius of the Taylor expansion. This difference arises from the very essence of Dante’s Inferno model that the effective inflaton potential is stretched in the inflaton field direction compared with the potential for the original field.

  14. Maximum tolerated dose in a phase I trial on adaptive dose painting by numbers for head and neck cancer

    International Nuclear Information System (INIS)

    Madani, Indira; Duprez, Fréderic; Boterberg, Tom; Van de Wiele, Christophe; Bonte, Katrien; Deron, Philippe; De Gersem, Werner; Coghe, Marc; De Neve, Wilfried

    2011-01-01

    Purpose: To determine the maximum tolerated dose (MTD) in a phase I trial on adaptive dose-painting-by-numbers (DPBN) for non-metastatic head and neck cancer. Materials and methods: Adaptive intensity-modulated radiotherapy was based on voxel intensity of pre-treatment and per-treatment [ 18 F]fluoro-2-deoxy-D-glucose positron emission tomography ( 18 F-FDG-PET) scans. Dose was escalated to a median total dose of 80.9 Gy in the high-dose clinical target volume (dose level I) and 85.9 Gy in the gross tumor volume (dose level II). The MTD would be reached, if ⩾33% of patients developed any grade ⩾4 toxicity (DLT) up to 3 months follow-up. Results: Between February 2007 and August 2009, seven patients at dose level I and 14 at dose level II were treated. All patients completed treatment without interruption. At a median follow-up for surviving patients of 38 (dose level I) and 22 months (dose level II) there was no grade ⩾4 toxicity during treatment and follow-up but six cases of mucosal ulcers at latency of 4–10 months, of which five (36%) were observed at dose level II. Mucosal ulcers healed spontaneously in four patients. Conclusions: Considering late mucosal ulcers as DLT, the MTD of a median dose of 80.9 Gy has been reached in our trial.

  15. Higher-Than-Conventional Radiation Doses in Localized Prostate Cancer Treatment: A Meta-analysis of Randomized, Controlled Trials

    International Nuclear Information System (INIS)

    Viani, Gustavo Arruda; Stefano, Eduardo Jose; Afonso, Sergio Luis

    2009-01-01

    Purpose: To determine in a meta-analysis whether the outcomes in men with localized prostate cancer treated with high-dose radiotherapy (HDRT) are better than those in men treated with conventional-dose radiotherapy (CDRT), by quantifying the effect of the total dose of radiotherapy on biochemical control (BC). Methods and Materials: The MEDLINE, EMBASE, CANCERLIT, and Cochrane Library databases, as well as the proceedings of annual meetings, were systematically searched to identify randomized, controlled studies comparing HDRT with CDRT for localized prostate cancer. To evaluate the dose-response relationship, we conducted a meta-regression analysis of BC ratios by means of weighted linear regression. Results: Seven RCTs with a total patient population of 2812 were identified that met the study criteria. Pooled results from these RCTs showed a significant reduction in the incidence of biochemical failure in those patients with prostate cancer treated with HDRT (p 2 gastrointestinal toxicity after HDRT than after CDRT. In the subgroup analysis, patients classified as being at low (p = 0.007), intermediate (p < 0.0001), and high risk (p < 0.0001) of biochemical failure all showed a benefit from HDRT. The meta-regression analysis also detected a linear correlation between the total dose of radiotherapy and biochemical failure (BC = -67.3 + [1.8 x radiotherapy total dose in Gy]; p = 0.04). Conclusions: Our meta-analysis showed that HDRT is superior to CDRT in preventing biochemical failure in low-, intermediate-, and high-risk prostate cancer patients, suggesting that this should be offered as a treatment for all patients, regardless of their risk status.

  16. External beam radiotherapy for painful osseous metastases: pooled data dose response analysis

    International Nuclear Information System (INIS)

    Ben-Josef, Edgar; Shamsa, Falah; Youssef, Emad; Porter, Arthur T.

    1999-01-01

    Purpose: Although the effectiveness of external beam irradiation in palliation of pain from osseous metastases is well established, the optimal fractionation schedule has not been determined. Clinical studies to date have failed to demonstrate an advantage for higher doses. To further address this issue, we conducted a pooled dose response analysis using data from published Phase III clinical trials. Methods and Materials: Complete response (CR) was used as an endpoint because it was felt to be least susceptible to inconsistencies in assessment.The biological effective dose (BED) was calculated for each schedule using the linear-quadratic model and an α/β of 10. Using SAS version 6.12, the data were fitted using a weighted linear regression, a logistic model, and the spline technique. Finally, BED was categorized, and odds ratios for each level were calculated. Results: CR was assessed early and late in 383 and 1,007 patients, respectively. Linear regression on the early-response data yielded a poor fit and a nonsignificant dose coefficient. With the late-response data, there was an excellent fit (R-square = 0.842) and a highly significant dose coefficient (p = 0.0002). Fitting early CR to a logistic model, we could not establish a significant dose response relationship. However, with the late-response data there was an excellent fit and the dose coefficient was significantly different from zero (0.017 ± 0.00524; p = 0.0012). Application of the spline technique or removal of an outlier resulted in an improved fit (p 0.048 and p = 0.0001, respectively). Using BED of < 14.4 Gy as a reference level, the odds ratios for late CR were 2.29-3.32 (BED of 19.5-51.4 Gy, respectively). Conclusion: Our results demonstrate a clear dose-response for pain relief. Further testing of high intensity regiments is warranted

  17. Occupational radiation dose in Indonesia 1981-1986

    International Nuclear Information System (INIS)

    Hiswara, E.; Ismono, A.

    1993-01-01

    Occupational radiation dose in Indonesia 1981-1986. This paper presents the occupational radiation dose in Indonesia during the period of 1981-1986. The highest collective dose accurated in 1983 was calculated to be 2.68 man-Sv, with the maximum mean dose per worker, who received dose more than zero, was around 11.07 mSv in the same year. In 1985, a relative collective dose from medical occupations of 1.88 man mSv for 10 6 population was estimated based on its total collective dose of 0.31 man-mSv. The total number of workers who received annual collective dose less than 5 mSv varied from 97.0% in 1981 to 99.5% in 1986. As a group, the industrial occupations has considerably higher risk in receiving a dose than others. (authors). 11 refs., 7 tabs

  18. Skin and gonadal dose reduction during hip radiography of the bull

    International Nuclear Information System (INIS)

    Wood, A.K.W.; Blockey, deB.; Reynolds, K.M.; Leith, I.S.; Burns, P.A.

    1979-01-01

    Radiology is being used to an increasing extent in the clinical diagnosis of hip lameness in bulls. Consequent gonadal doses may have important implications in later breeding programmes. Skin and gonadal doses were recorded during hip radiography of 18 bulls. An additional 0.13 mm copper filtration reduced skin dose by more than one third, but had no effect on gonadal dose. The average radiation dose to the gonads was approximately halved by completely surrounding the scrotum with lead sheeting 0.95 mm in thickness. (author)

  19. Mammography-oncogenecity at low doses

    International Nuclear Information System (INIS)

    Heyes, G J; Mill, A J; Charles, M W

    2009-01-01

    Controversy exists regarding the biological effectiveness of low energy x-rays used for mammography breast screening. Recent radiobiology studies have provided compelling evidence that these low energy x-rays may be 4.42 ± 2.02 times more effective in causing mutational damage than higher energy x-rays. These data include a study involving in vitro irradiation of a human cell line using a mammography x-ray source and a high energy source which matches the spectrum of radiation observed in survivors from the Hiroshima atomic bomb. Current radiation risk estimates rely heavily on data from the atomic bomb survivors, and a direct comparison between the diagnostic energies used in the UK breast screening programme and those used for risk estimates can now be made. Evidence highlighting the increase in relative biological effectiveness (RBE) of mammography x-rays to a range of x-ray energies implies that the risks of radiation-induced breast cancers for mammography x-rays are potentially underestimated by a factor of four. A pooled analysis of three measurements gives a maximal RBE (for malignant transformation of human cells in vitro) of 4.02 ± 0.72 for 29 kVp (peak accelerating voltage) x-rays compared to high energy electrons and higher energy x-rays. For the majority of women in the UK NHS breast screening programme, it is shown that the benefit safely exceeds the risk of possible cancer induction even when this higher biological effectiveness factor is applied. The risk/benefit analysis, however, implies the need for caution for women screened under the age of 50, and particularly for those with a family history (and therefore a likely genetic susceptibility) of breast cancer. In vitro radiobiological data are generally acquired at high doses, and there are different extrapolation mechanisms to the low doses seen clinically. Recent low dose in vitro data have indicated a potential suppressive effect at very low dose rates and doses. Whilst mammography is a low

  20. Process control and dosimetry applied to establish a relation between reference dose measurements and actual dose distribution

    Energy Technology Data Exchange (ETDEWEB)

    Ehlerman, D A.E. [Institute of Process Engineering, Federal Research Centre for Nutrition, Karlsruhe (Germany)

    2001-03-01

    The availability of the first commercial dose level indicator prompted attempts to verify radiation absorbed dose to items under quarantine control (e.g. for insect disinfestation) by some indicator attached to these items. Samples of the new commercial dose level indicators were tested for their metrological properties using gamma and electron irradiation. The devices are suitable for the intended purpose and the subjective judgement whether the threshold dose was surpassed is possible in a reliable manner. The subjective judgements are completely backed by the instrumental results. Consequently, a prototype reader was developed; first tests were successful. The value of dose level indicators and the implications of its use for food or quarantine inspection depends on a link between dose measured (indicated) at the position of such indicator and the characteristic parameters of the frequency distribution of dose throughout the product load i.e. a box or a container or a whole batch of multiple units. Therefore, studies into variability and statistical properties of dose distributions obtained under a range of commercial situations were undertaken. Gamma processing at a commercial multipurpose contract irradiator, electron processing and bremsstrahlung applications at a largescale research facility were included; products were apples, potatoes, wheat, maize, pistachio. Studies revealed that still more detailed information on irradiation geometries are needed in order to render meaningful information from dose label indicators. (author)

  1. Process control and dosimetry applied to establish a relation between reference dose measurements and actual dose distribution

    International Nuclear Information System (INIS)

    Ehlerman, D.A.E.

    2001-01-01

    The availability of the first commercial dose level indicator prompted attempts to verify radiation absorbed dose to items under quarantine control (e.g. for insect disinfestation) by some indicator attached to these items. Samples of the new commercial dose level indicators were tested for their metrological properties using gamma and electron irradiation. The devices are suitable for the intended purpose and the subjective judgement whether the threshold dose was surpassed is possible in a reliable manner. The subjective judgements are completely backed by the instrumental results. Consequently, a prototype reader was developed; first tests were successful. The value of dose level indicators and the implications of its use for food or quarantine inspection depends on a link between dose measured (indicated) at the position of such indicator and the characteristic parameters of the frequency distribution of dose throughout the product load i.e. a box or a container or a whole batch of multiple units. Therefore, studies into variability and statistical properties of dose distributions obtained under a range of commercial situations were undertaken. Gamma processing at a commercial multipurpose contract irradiator, electron processing and bremsstrahlung applications at a largescale research facility were included; products were apples, potatoes, wheat, maize, pistachio. Studies revealed that still more detailed information on irradiation geometries are needed in order to render meaningful information from dose label indicators. (author)

  2. Dose calculation for photon-emitting brachytherapy sources with average energy higher than 50 keV: report of the AAPM and ESTRO.

    Science.gov (United States)

    Perez-Calatayud, Jose; Ballester, Facundo; Das, Rupak K; Dewerd, Larry A; Ibbott, Geoffrey S; Meigooni, Ali S; Ouhib, Zoubir; Rivard, Mark J; Sloboda, Ron S; Williamson, Jeffrey F

    2012-05-01

    Recommendations of the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO) on dose calculations for high-energy (average energy higher than 50 keV) photon-emitting brachytherapy sources are presented, including the physical characteristics of specific (192)Ir, (137)Cs, and (60)Co source models. This report has been prepared by the High Energy Brachytherapy Source Dosimetry (HEBD) Working Group. This report includes considerations in the application of the TG-43U1 formalism to high-energy photon-emitting sources with particular attention to phantom size effects, interpolation accuracy dependence on dose calculation grid size, and dosimetry parameter dependence on source active length. Consensus datasets for commercially available high-energy photon sources are provided, along with recommended methods for evaluating these datasets. Recommendations on dosimetry characterization methods, mainly using experimental procedures and Monte Carlo, are established and discussed. Also included are methodological recommendations on detector choice, detector energy response characterization and phantom materials, and measurement specification methodology. Uncertainty analyses are discussed and recommendations for high-energy sources without consensus datasets are given. Recommended consensus datasets for high-energy sources have been derived for sources that were commercially available as of January 2010. Data are presented according to the AAPM TG-43U1 formalism, with modified interpolation and extrapolation techniques of the AAPM TG-43U1S1 report for the 2D anisotropy function and radial dose function.

  3. Low-dose prophylactic craniospinal radiotherapy for intracranial germinoma

    International Nuclear Information System (INIS)

    Schoenfeld, Gordon O.; Amdur, Robert J.; Schmalfuss, Ilona M.; Morris, Christopher G.; Keole, Sameer R.; Mendenhall, William M.; Marcus, Robert B.

    2006-01-01

    Purpose: To report outcomes of patients with localized intracranial germinoma treated with low-dose craniospinal irradiation (CSI) followed by a boost to the ventricular system and primary site. Methods and Materials: Thirty-one patients had pathologically confirmed intracranial germinoma and no spine metastases. Low-dose CSI was administered in 29 patients: usually 21 Gy of CSI, 9.0 Gy of ventricular boost, and a 19.5-Gy tumor boost, all at 1.5 Gy per fraction. Our neuroradiologist recorded three-dimensional tumor size on magnetic resonance images before, during, and after radiotherapy. Results: With a median follow-up of 7.0 years, 29 of 31 patients (94%) are disease free. One failure had nongerminomatous histology; the initial diagnosis was a sampling error. Of 3 patients who did not receive CSI, 1 died. No patient developed myelopathy, visual deficits, dementia, or skeletal growth problems. In locally controlled patients, tumor response according to magnetic resonance scan was nearly complete within 6 months after radiotherapy. Conclusions: Radiotherapy alone with low-dose prophylactic CSI cures almost all patients with localized intracranial germinoma. Complications are rare when the daily dose of radiotherapy is limited to 1.5 Gy and the total CSI dose to 21 Gy. Patients without a near-complete response to radiotherapy should undergo resection to rule out a nongerminomatous element

  4. Methods of bone marrow dose calculation

    International Nuclear Information System (INIS)

    Taboaco, R.C.

    1982-02-01

    Several methods of bone marrow dose calculation for photon irradiation were analised. After a critical analysis, the author proposes the adoption, by the Instituto de Radioprotecao e Dosimetria/CNEN, of Rosenstein's method for dose calculations in Radiodiagnostic examinations and Kramer's method in case of occupational irradiation. It was verified by Eckerman and Simpson that for monoenergetic gamma emitters uniformly distributed within the bone mineral of the skeleton the dose in the bone surface can be several times higher than dose in skeleton. In this way, is also proposed the Calculation of tissue-air ratios for bone surfaces in some irradiation geometries and photon energies to be included in the Rosenstein's method for organ dose calculation in Radiodiagnostic examinations. (Author) [pt

  5. The irradiation tolerance dose of the proximal vagina

    International Nuclear Information System (INIS)

    Au, Samuel P.; Grigsby, Perry W.

    2003-01-01

    Purpose: The purpose of this investigation was to determine the irradiation tolerance level and complication rates of the proximal vagina to combined external irradiation and low dose rate (LDR) brachytherapy. Also, the mucosal tolerance for fractionated high dose rate (HDR) brachytherapy is further projected based on the biological equivalent dose (BED) of LDR for an acceptable complication rate. Materials and methods: Two hundred seventy-four patients with stages I-IV cervical carcinoma treated with irradiation therapy alone from 1987 to 1997 were retrospectively reviewed for radiation-associated late sequelae of the proximal vagina. All patients received LDR brachytherapy and 95% also received external pelvic irradiation. Follow-up ranged from 15 to 126 months (median, 43 months). The proximal vagina mucosa dose from a single ovoid (single source) or from both ovoids plus the tandem (all sources), together with the external irradiation dose, were used to derive the probability of a complication using the maximum likelihood logistic regression technique. The BED based on the linear-quadratic model was used to compute the corresponding tolerance levels for LDR or HDR brachytherapy. Results: Grades 1 and 2 complications occurred in 10.6% of patients and Grade 3 complications occurred in 3.6%. There were no Grade 4 complications. Complications occurred from 3 to 71 months (median, 7 months) after completion of irradiation, with over 60% occurring in the first year. By logistic regression analysis, both the mucosal dose from a single ovoid or that from all sources, combined with the external irradiation dose, demonstrate a statistically significant fit to the dose response complication curves (both with P=0.016). The single source dose was highly correlated with the all source dose with a cross-correlation coefficient 0.93. The all source dose was approximately 1.4 times the single source dose. Over the LDR brachytherapy dose rate range, the complication rate was

  6. Employee dose reduction at British Nuclear Fuels plc

    International Nuclear Information System (INIS)

    Fishwick, A.H.; Finlayson, J.L.; James, R.D.

    1992-01-01

    Average work force doses in uranium fuel fabrication plants are a small percentage (about 6 % or 3 mSv pa) of UK regulatory limits. In uranium metal casting, and uranium oxide production plants, doses are somewhat higher than the average. Dose reduction methods have, however, resulted in these being reduced to 20 %, or less, of the same limit. Major future investment should reduce doses in oxide production plants to about the current average level. (author)

  7. SU-E-T-611: Photon and Neutron Peripheral Dose Ratio for Low (6 MV) and High (15 MV) Energy for Treatment Selection

    Energy Technology Data Exchange (ETDEWEB)

    Irazola, L; Sanchez-Doblado, F [Departamento de Fisiologia Medica y Biofisica, Universidad de Seville (Spain); Servicio de Radiofisica, Hospital Universitario Virgen Macarena, Seville (Spain); Terron, J; Ortiz-Seidel, M [Servicio de Radiofisica, Hospital Universitario Virgen Macarena, Seville (Spain); Departamento de Fisiologia Medica y Biofisica, Universidad de Seville (Spain); Sanchez-Nieto, B [Instituto de Fisica, Pontificia Universidad Catolica de Chile, Santiago (Chile)

    2015-06-15

    Purpose: Differences between radiotherapy techniques and energies, can offer improvements in tumor coverage and organs at risk preservation. However, a more complete decision should include peripheral doses delivered to the patient. The purpose of this work is the balance of photon and neutron peripheral doses for a prostate case solved with 6 different treatment modalities. Methods: Inverse and Forward IMRT and 3D-CRT in 6 and 15 MV for a Siemens Primus linac, using the same CT data set and contours. The methodology described in [1], was used with the TNRD thermal neutron detector [2] for neutron peripheral dose estimation at 7 relevant organs (colon, esophagus, stomach, liver, lung, thyroid and skin). Photon doses were estimated for these organs by terms of the algorithm proposed in [3]. Plans were optimized with the same restrictions and limited to 30 segments in the Inverse case. Results: A similar photon peripheral dose was found comparing 6 and 15 MV cases with slightly higher values of (1.9 ± 1.6) % in mean, for the 6 MV cases. Neutron presence when using 15 MV, represents an increase in peripheral dose of (18 ± 17) % in average. Due to the higher number of MU used in Inverse IMRT, an increasing of (22 ± 3) % in neutron dose is found related to Forward and 3D-CRT plans. This corresponds to photon doses within 44 and 255 mSv along the organs, for a dose prescription of 68 Gy at the isocenter. Conclusion: Neutron and photon peripheral doses for a prostate treatment planified in 6 different techniques have been analyzed. 6 MV plans are slightly more demanding in terms of photon peripheral doses. Inverse technique in 15 MV has Result to be the most demanding one in terms of total peripheral doses, including neutrons and photons.

  8. Estimation of Absorbed Dose in Occlusal Radiography

    International Nuclear Information System (INIS)

    Yoo, Young Ah; Choi, Karp Shick; Lee, Sang Han

    1990-01-01

    The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-210 Head and Neck Section R, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70 Kvp and 15 mA, 1/4 second (8 inch cone ) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In Mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  9. The D1 method: career dose estimation from a combination of historical monitoring data and a single year's dose data

    International Nuclear Information System (INIS)

    Sont, W.N.

    1995-01-01

    A method is introduced to estimate career doses from a combination of historical monitoring data and a single year's dose data. This method, called D1 eliminates the bias arising from incorporating historical dose data from times when occupational doses were generally much higher than they are today. Doses calculated by this method are still conditional on the preservation of the status quo in the effectiveness of radiation protection. The method takes into account the variation of the annual dose, and of the probability of being monitored, with the time elapsed since the start of a career. It also allows for the calculation of a standard error of the projected career dose. Results from recent Canadian dose data are presented. (author)

  10. Increasing Completion Rate of an M4 Emergency Medicine Student End-of-Shift Evaluation Using a Mobile Electronic Platform and Real-Time Completion

    Directory of Open Access Journals (Sweden)

    Matthew C. Tews

    2016-06-01

    Full Text Available Introduction: Medical students on an emergency medicine rotation are traditionally evaluated at the end of each shift with paper-based forms, and data are often missing due to forms not being turned in or completed. Because students’ grades depend on these evaluations, change was needed to increase form rate of return. We analyzed a new electronic evaluation form and modified completion process to determine if it would increase the completion rate without altering how faculty scored student performance. Methods: During fall 2013, 29 faculty completed paper N=339 evaluations consisting of seven competencies for 33 students. In fall 2014, an electronic evaluation form with the same competencies was designed using an electronic platform and completed N=319 times by 27 faculty using 25 students’ electronic devices. Feedback checkboxes were added to facilitate collection of common comments. Data was analyzed with IBM® SPSS® 21.0 using multi-factor analysis of variance with the students’ global rating (GR as an outcome. Inter-item reliability was determined with Cronbach alpha. Results: There was a significantly higher completion rate (p=0.001 of 98% electronic vs. 69% paper forms, lower (p=0.001 missed GR rate (1% electronic. vs 12% paper, and higher mean scores (p=0.001 for the GR with the electronic (7.0±1.1 vs. paper (6.8±1.2 form. Feedback checkboxes were completed on every form. The inter-item reliability for electronic and paper forms was each alpha=0.95. Conclusion: The use of a new electronic form and modified completion process for evaluating students at the end of shift demonstrated a higher faculty completion rate, a lower missed data rate, a higher global rating and consistent collection of common feedback. The use of the electronic form and the process for obtaining the information made our end-of-shift evaluation process for students more reliable and provided more accurate, up-to-date information for student feedback and when

  11. Method to stimulate dose gradient in liquid media

    International Nuclear Information System (INIS)

    Scarlat, F.

    1993-01-01

    The depth absorbed dose from electrons with energy higher than 10 MeV shows a distribution with a big-percentage absorbed dose at the entrance surface and a small dose gradient. This is due to the big distance between the virtual focus and irradiated liquid medium. In order to stimulate dose gradient and decrease the surface dose, this paper presents a method for obtaining the second focus by means of a magnetostatic planar wiggler. Preliminary calculations indicated that the absorbed dose rate increases two-three times at the reference plane in the irradiated liquid medium. (Author)

  12. A comprehensive comparative study of the pre-dose effect for three quartz crystals of different origin

    International Nuclear Information System (INIS)

    Kitis, G.; Pagonis, V.; Chen, R.; Polymeris, G.

    2006-01-01

    The study of the thermoluminescence (TL) sensitivity of quartz due to heat and irradiation treatments is of importance in dating and retrospective dosimetry. A comprehensive comparative study of the pre-dose effect was carried out for three types of quartz of different origin. Complete TL vs. dose and sensitivity S vs. pre-dose curves were obtained for the dose range of 0.1 < D < 400 Gy. Additional complete sensitivity vs. pre-dose curves were obtained for samples which underwent a combined pre-dose irradiation and a subsequent heat treatment to 500 deg. C. Although the TL vs. dose curves showed very different behaviours, the sensitivity vs. pre-dose curves showed several common characteristics. The sensitivity vs. pre-dose curves showed abrupt changes ∼10 Gy. The sensitivity after a combined pre-dose irradiation and heat treatment to 500 deg. C showed a very gradual change in the whole dose range studied. These results are explained qualitatively by using the modified Zimmerman model for quartz. (authors)

  13. A practical approach to determine dose metrics for nanomaterials.

    Science.gov (United States)

    Delmaar, Christiaan J E; Peijnenburg, Willie J G M; Oomen, Agnes G; Chen, Jingwen; de Jong, Wim H; Sips, Adriënne J A M; Wang, Zhuang; Park, Margriet V D Z

    2015-05-01

    Traditionally, administered mass is used to describe doses of conventional chemical substances in toxicity studies. For deriving toxic doses of nanomaterials, mass and chemical composition alone may not adequately describe the dose, because particles with the same chemical composition can have completely different toxic mass doses depending on properties such as particle size. Other dose metrics such as particle number, volume, or surface area have been suggested, but consensus is lacking. The discussion regarding the most adequate dose metric for nanomaterials clearly needs a systematic, unbiased approach to determine the most appropriate dose metric for nanomaterials. In the present study, the authors propose such an approach and apply it to results from in vitro and in vivo experiments with silver and silica nanomaterials. The proposed approach is shown to provide a convenient tool to systematically investigate and interpret dose metrics of nanomaterials. Recommendations for study designs aimed at investigating dose metrics are provided. © 2015 SETAC.

  14. Complete heart block in a 9 year old girl caused by borreliosis.

    Science.gov (United States)

    Gildein, H P; Günther, S; Mocellin, R

    1993-01-01

    A complete atrioventricular block was seen in a nine year old girl in whom an infection with Borrelia burgdorferi was confirmed by serological testing. There were no other symptoms or cutaneous manifestations of the disease. Though a rash on the right ear was later recalled by her parents. The patient was treated with high dose penicillin and orciprenaline was given intermittently. The complete heart block disappeared within four days. PMID:8038006

  15. Influence of radiation dose on positive surgical margins in women undergoing breast conservation therapy

    International Nuclear Information System (INIS)

    DiBiase, Steven J.; Komarnicky, Lydia T.; Heron, Dwight E.; Schwartz, Gordon F.; Mansfield, Carl M.

    2002-01-01

    Purpose: Positive surgical margins adversely influence local tumor control in breast conservation therapy (BCT). However, reports have conflicted regarding whether an increased radiation dose can overcome this poor prognostic factor. In this study, we evaluated the influence of an increased radiation dose on tumor control in women with positive surgical margins undergoing BCT. Methods and Materials: Between 1978 and 1994, 733 women with pathologic Stage I-II breast cancer and known surgical margin status were treated at Thomas Jefferson University Hospital with BCT. Of these 733 patients, 641 women had a minimal tumor bed dose of 60 Gy and had documentation of their margin status; 509 had negative surgical margins, and 132 had positive surgical margins before definitive radiotherapy. Complete gross excision of the tumor and axillary lymph node sampling was obtained in all patients. The median radiation dose to the primary site was 65.0 Gy (range 60-76). Of the women with positive margins (n=132), the influence of higher doses of radiotherapy was evaluated. The median follow-up time was 52 months. Results: The local tumor control rate for patients with negative margins at 5 and 10 years was 94% and 88%, respectively, compared with 85% and 67%, respectively, for those women with positive margins (p=0.001). The disease-free survival rate for the negative margin group at 5 and 10 years was 91% and 82%, respectively, compared with 76% and 71%, respectively, for the positive margin group (p = 0.001). The overall survival rate of women with negative margins at 5 and 10 years was 95% and 90%, respectively. By comparison, for women with positive surgical margins, the overall survival rate at 5 and 10 years was 86% and 79%, respectively (p=0.008). A comparison of the positive and negative margin groups revealed that an increased radiation dose (whether entered as a dichotomous or a continuous variable) >65.0 Gy did not improve local tumor control (p=0.776). On Cox

  16. High-dose irradiation of food

    International Nuclear Information System (INIS)

    Diehl, J.F.

    1999-01-01

    Studies performed on behalf of the International Project on Food Irradiation in the period from 1971 until 1980 resulted in the concluding statement that ''.the irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard; hence, toxicological testing of foods so treated is no longer required.'' Since then, licenses for food irradiation have been restricted to this maximum dose in any country applying this technology. Further testing programmes have been carried out investigating the wholesomeness or hazards of high-dose irradiation, but there has been little demand so far by the food industry for licensing of high-dose irradiation, as there is only a small range of products whose irradiation at higher doses offers advantages for given, intended use. These include eg. spices, dried herbs, meat products in flexible pouch packagings for astronauts, or patients with immune deficiencies. (orig./CB) [de

  17. Labour cost of radiation dose

    International Nuclear Information System (INIS)

    Cook, A.; Lockett, L.E.

    1978-01-01

    In order to optimise capital expenditure on measures to protect workers against radiation it would be useful to have a means to measure radiation dose in money terms. Because labour has to be employed to perform radiation work there must be some relationship between the wages paid and the doses received. Where the next increment of radiation dose requires additional labour to be recruited the cost will at least equal the cost of the extra labour employed. This paper examines some of the factors which affect the variability of the labour cost of radiation dose and notes that for 'in-plant' exposures the current cost per rem appears to be significantly higher than values quoted in ICRP Publication 22. An example is given showing how this concept may be used to determine the capital it is worth spending on installed plant to prevent regular increments of radiation dose to workers. (author)

  18. Dose profile of a dental facilities

    International Nuclear Information System (INIS)

    Silva Borges, D. da; Lava, D.D.; Moreira, M. de L.; Ferreira Guimaraes, A.C.; Silva, L. Fernandes da

    2015-01-01

    The determination of the dose profile is important to classify the level of danger which the individuals are exposed (considering their positioning) in dental facilities. From this, this paper aims to present a methodology capable of mapping the dose within dental rooms in three dimensions. The methodology used for dose mapping in conjunction with techniques for calculating shielding for dental facilities, provided by the National Council on Radiation Protection and Measurements (NCRP), form a complete system able to generate meaningful data on the safety of occupationally Exposed Individuals (IOEs) and of the public. As the dose is strongly dependent on the distance, the estimated value of the initial dose was made in the isocenter of the source. This value was adopted because the model of dose calculus tends to infinity when it is desired to analyze points very close of the source. The model of room to be presented, as a case of illustration of the methodology, was arbitrarily constructed to generate better understanding of the problem. Its inclusion in the calculus was made through discretizations performed with the aid of high-performance computers. This discretizations allowed the obtain of dose values for an infinitesimal distance after the start point. (authors)

  19. [Correction of the combined vitamin deficiency in growing rats fed fiber enriched diets with different doses of vitamins].

    Science.gov (United States)

    Beketova, N A; Kodentsova, V M; Vrzhesinskaia, O A; Kosheleva, O V; Pereverzeva, O G; Sokol'nikov, A A; Aksenov, I V

    2014-01-01

    The effect of 5% dietary wheat bran (WB) on the correction of combined vitamin deficiency by two doses of vitamins (physiological and enhanced) has been analyzed using a rat model (8 groups, n = 8/group). Vitamin deficiency in male weanling Wistar rats (58.1 ± 0.5 g) was induced by 5-fold reduction of vitamin mixture amount in the feed and complete vitamin E, B1 and B2 exclusion from the mixture for 30 days, then deficit was corrected within 5 days. Rats from control group were fed a complete semisynthetic diet containing microcrystalline cellulose 2%. Vitamin deficient diet for 35 days resulted in reduced (p vitamin A in the liver by 25 fold, vitamin E and B1--2.0-2.3 fold, vitamin B2--by 40%, 25(OH)D blood plasma concentration--by 21% compared with the control. Feed consumption of the animals treated with vitamin deficient diet and WB was higher by 43% than in rats with vitamin deficit. Their rate of weight occupied the intermediate position between the rates of weight in deficit and in control animals, and they could not serve a full control to evaluate the WB impact on vitamin sufficiency. After filling the vitamin diet content to an adequate level vitamin E liver content was fully restored. To restore vitamins B1 and B2 liver level higher doses of vitamins (120-160% of adequate content) were required, and to restore the reduced levels of vitamin A in rat liver even 2-fold increased dose of vitamin A was insufficient. The diet enrichment with WB had no effect on vitamin B1 and B2 liver content, regardless of the amount of vitamins in the diet. Adding fiber to the diet of animals adequately provided with vitamins resulted in significantly 1,3-fold increase of 25(OH)D blood plasma concentration and a slight but significant decrease of α-tocopherol liver level by 16% as compared to rats not receiving WB. The enrichment of rat diet with dietary fibers worsened restoration of the reduced vitamin E status not only by filling vitamin content in the diet to an

  20. Immunogenicity to poliovirus type 2 following two doses of fractional intradermal inactivated poliovirus vaccine: A novel dose sparing immunization schedule.

    Science.gov (United States)

    Anand, Abhijeet; Molodecky, Natalie A; Pallansch, Mark A; Sutter, Roland W

    2017-05-19

    The polio eradication endgame strategic plan calls for the sequential removal of Sabin poliovirus serotypes from the trivalent oral poliovirus vaccine (tOPV), starting with type 2, and the introduction of ≥1 dose of inactivated poliovirus vaccine (IPV), to maintain an immunity base against poliovirus type 2. The global removal of oral poliovirus type 2 was successfully implemented in May 2016. However, IPV supply constraints has prevented introduction in 21 countries and led to complete stock-out in >20 countries. We conducted a literature review and contacted corresponding authors of recent studies with fractional-dose IPV (fIPV), one-fifth of intramuscular dose administered intradermally, to conduct additional type 2 immunogenicity analyses of two fIPV doses compared with one full-dose IPV. Four studies were identified that assessed immunogenicity of two fIPV doses compared to one full-dose IPV. Two fractional doses are more immunogenic than 1 full-dose, with type 2 seroconversion rates improving between absolute 19-42% (median: 37%, pvaccine compared to one full-dose IPV. In response to the current IPV shortage, a schedule of two fIPV doses at ages 6 and 14weekshas been endorsed by technical oversight committees and has been introduced in some affected countries. Copyright © 2017. Published by Elsevier Ltd.

  1. Optimizing bevacizumab dosing in glioblastoma: less is more.

    Science.gov (United States)

    Ajlan, Abdulrazag; Thomas, Piia; Albakr, Abdulrahman; Nagpal, Seema; Recht, Lawrence

    2017-10-01

    Compared to traditional chemotherapies, where dose limiting toxicities represent the maximum possible dose, monoclonal antibody therapies are used at doses well below maximum tolerated dose. However, there has been little effort to ascertain whether there is a submaximal dose at which the efficacy/complication ratio is maximized. Thus, despite the general practice of using Bevacizumab (BEV) at dosages of 10 mg/kg every other week for glioma patients, there has not been much prior work examining whether the relatively high complication rates reported with this agent can be decreased by lowering the dose without impairing efficacy. We assessed charts from 80 patients who received BEV for glioblastoma to survey the incidence of complications relative to BEV dose. All patients were treated with standard upfront chemoradiation. The toxicity was graded based on the NCI CTCAE, version 4.03. The rate of BEV serious related adverse events was 12.5% (n = 10/80). There were no serious adverse events (≥grade 3) when the administered dose was (<3 mg/kg/week), compared to a 21% incidence in those who received higher doses (≥3 mg/kg/week) (P < 0.01). Importantly, the three patient deaths attributable to BEV administration occurred in patients receiving higher doses. Patients who received lower doses also had a better survival rate, although this did not reach statistical significance [median OS 39 for low dose group vs. 17.3 for high dose group (P = 0.07)]. Lower rates of serious BEV related toxicities are noted when lower dosages are used without diminishing positive clinical impact. Further work aimed at optimizing BEV dosage is justified.

  2. Measured dose to ovaries and testes from Hodgkin's fields and determination of genetically significant dose

    International Nuclear Information System (INIS)

    Niroomand-Rad, A.; Cumberlin, R.

    1993-01-01

    The purpose of this study was to determine the genetically significant dose from therapeutic radiation exposure with Hodgkin's fields by estimating the doses to ovaries and testes. Phantom measurements were performed to verify estimated doses to ovaries and testes from Hodgkin's fields. Thermoluminescent LiF dosimeters (TLD-100) of 1 x 3 x 3 mm 3 dimensions were embedded in phantoms and exposed to standard mantle and paraaortic fields using Co-60, 4 MV, 6 MV, and 10 MV photon beams. The results show that measured doses to ovaries and testes are about two to five times higher than the corresponding graphically estimated doses for Co-60 and 4 MVX photon beams as depicted in ICRP publication 44. In addition, the measured doses to ovaries and testes are about 30% to 65% lower for 10 MV photon beams than for their corresponding Co-60 photon beams. The genetically significant dose from Hodgkin's treatment (less than 0.01 mSv) adds about 4% to the genetically significant dose contribution to medical procedures and adds less than 1% to the genetically significant dose from all sources. Therefore, the consequence to society is considered to be very small. The consequences for the individual patient are, likewise, small. 28 refs., 3 figs., 5 tabs

  3. A practical and transferable methodology for dose estimation in irradiated spices based on thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    D'Oca, M.C.; Bartolotta, A.; Cammilleri, C.; Giuffrida, S.; Parlato, A.; Di Stefano, V.

    2008-01-01

    Full text: Among the industrial applications of ionizing radiation, the treatment of food for preservation purposes is a worldwide recognized tool, provided that proper and validated identification methods are available and used. The thermoluminescence (TL) dosimetry is the physical method validated by the European Committee for Standardization for food from which silicate minerals can be isolated, such as spices and aromatic herbs. The aim of this work was to set up a reasonably simple procedure, alternative to the recommended one, for the identification of irradiated spices and to estimate at the same time the original dose in the irradiated product, using TL and the additive dose method, even after months storage. We have already shown that the additive dose method can be applied with TL dosimetry, if the TL response of the silicate specimen after extraction is always added to the response after each irradiation; the applied added doses were higher than 1 kGy, that can however give saturation problems. The new proposed methodology makes use of added doses lower than 600 Gy; the entire process can be completed within few hours and a linear fit can be utilized. The method was applied to the silicates extracted from oregano samples soon after the radiation treatment (original dose: 2 - 3 - 5 kGy), and after one year storage at room conditions in the dark (original dose: 1-2 kGy). The procedure allows the identification of irradiated samples, without any false positive, together with an estimation of the dose range

  4. Dose distribution calculation for in-vivo X-ray fluorescence scanning

    International Nuclear Information System (INIS)

    Figueroa, R. G.; Lozano, E.; Valente, M.

    2013-01-01

    In-vivo X-ray fluorescence constitutes a useful and accurate technique, worldwide established for constituent elementary distribution assessment. Actually, concentration distributions of arbitrary user-selected elements can be achieved along sample surface with the aim of identifying and simultaneously quantifying every constituent element. The method is based on the use of a collimated X-ray beam reaching the sample. However, one common drawback for considering the application of this technique for routine clinical examinations was the lack of information about associated dose delivery. This work presents a complete study of the dose distribution resulting from an in-vivo X-ray fluorescence scanning for quantifying biohazard materials on human hands. Absorbed dose has been estimated by means of dosimetric models specifically developed to this aim. In addition, complete dose distributions have been obtained by means of full radiation transport calculations in based on stochastic Monte Carlo techniques. A dedicated subroutine has been developed using the Penelope 2008 main code also integrated with dedicated programs -Mat Lab supported- for 3 dimensional dose distribution visualization. The obtained results show very good agreement between approximate analytical models and full descriptions by means of Monte Carlo simulations. (Author)

  5. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    International Nuclear Information System (INIS)

    Morishima, Hiroshige; Koga, Taeko; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-01-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  6. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    Energy Technology Data Exchange (ETDEWEB)

    Morishima, Hiroshige; Koga, Taeko [Kinki Univ., Higashi-Osaka, Osaka (Japan). Atomic Energy Research Inst.; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-10-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  7. Fractionated total body irradiation and autologous bone marrow transplantation in dogs: Hemopoietic recovery after various marrow cell doses

    International Nuclear Information System (INIS)

    Bodenburger, U.; Kolb, H.J.; Thierfelder, S.; Netzel, B.; Schaeffer, E.; Kolb, H.

    1980-01-01

    Hemopoietic recovery was studied in dogs given 2400 R fractionated total body irradiation within one week and graded doses of cryopreserved autologous bone marrow. Complete hemopoietic recovery including histology was observed after this dose and sufficient doses of marrow cells. Doses of more than 5.5 x 10 7 mononuclear marrow cells/kg body weight were sufficient for complete recovery in all dogs, 1.5 to 5.5 x 10 7 cells/kg were effective in some of the dogs and less than 1.5 x 10 7 cells/kg were insufficient for complete recovery. Similarly, more than 30000 CFUsub(c)/kg body weight were required for hemopoietic recovery. The optimal marrow cell dose which has been defined as the minimal dose required for the earliest possible recovery of leukocyte and platelet counts was 7-8 x 10 7 mononuclear marrow cells/kg body weight. It has been concluded that fractionated total body irradiation with 2400 R dose not require greater doses of marrow cells for hemopoietic reconstitution than lower single doses and that the hemopoietic microenvironment is not persistently disturbed after this dose. (author)

  8. Effect of low-dose versus higher-dose antenatal iron supplementation on child health outcomes at 36 months of age in Viet Nam: longitudinal follow-up of a cluster randomised controlled trial.

    Science.gov (United States)

    Hanieh, Sarah; Ha, Tran T; Simpson, Julie A; Braat, Sabine; Thuy, Tran T; Tran, Thach D; King, Janet; Tuan, Tran; Fisher, Jane; Biggs, Beverley-Ann

    2017-01-01

    Intermittent iron-folic acid supplementation (IFA) is currently recommended for pregnant women in populations where anaemia prevalence among pregnant women is Viet Nam among children of 36 months of age, born to women previously enrolled in a cluster randomised controlled trial of antenatal micronutrient supplementation (daily IFA (60 mg elemental iron) vs twice-weekly IFA (60 mg elemental iron) vs twice-weekly multiple micronutrient (MMN) supplementation (60 mg elemental iron)). Primary outcomes were height-for-age z-scores (HAZ), according to WHO growth standards and cognitive composite scores (Bayley Scales of Infant and Toddler Development, third edition) at 36 months of age. A total of 1017 children born to mothers enrolled in the cluster randomised trial were assessed at 36 months of age. Adjusted mean differences (MDs) in HAZ were -0.14 (95% CI -0.28 to -0.01) and -0.15 (95% CI -0.29 to -0.01) in children born to mothers who received twice-weekly IFA or MMN compared with those who received daily IFA. Children born to mothers who received twice-weekly MMN had lower composite motor scores compared with those who received daily IFA (MD -2.07, 95% CI -4.11 to -0.03). There were no differences in composite cognitive scores in the twice-weekly compared with daily regimens. Low-dose antenatal IFA supplementation (120 mg elemental iron per week) resulted in lower HAZ and motor composite scores in children compared with higher-dose antenatal IFA supplementation (420 mg elemental iron per week). This highlights the importance of adequate iron stores during pregnancy and the need for careful monitoring when lower-dose antenatal iron regimens are used. Australia New Zealand Clinical Trials Registry: 12610000944033.

  9. Lateral rectal shielding reduces late rectal morbidity after high dose three-dimensional conformal radiation therapy for clinically localized prostate cancer: further evidence for a dose effect

    Energy Technology Data Exchange (ETDEWEB)

    Lee, W Robert; Hanks, Gerald E; Hanlon, Alexandra; Schultheiss, Timothy E

    1995-07-01

    Purpose: Using conventional treatment methods for the treatment of clinically localized prostate cancer central axis doses must be limited to 65-70 Gy to prevent significant damage to nearby normal tissues. A fundamental hypothesis of three-dimensional conformal radiation therapy (3DCRT) is that, by defining the target organ(s) accurately in three dimensions, it is possible to deliver higher doses to the target without a significant increase in normal tissue complications. This study examines whether this hypothesis holds true and whether a simple modification of treatment technique can reduce the incidence of late rectal morbidity in patients with prostate cancer treated with 3DCRT to minimum planning target volume (PTV) doses of 71-75 Gy. Materials and Methods: 257 patients with clinically localized prostate cancer completed 3DCRT by December 31, 1993 and received a minimum PTV dose of 71-75 Gy. The median follow-up time was 22 months (range 4-67 months) and 98% of patients had followup of longer than 12 months. The calculated dose at the center of the prostate was <74 Gy in 19 patients, 74-76 Gy in 206 patients and >76 Gy in 32 patients. Late rectal morbidity was graded according to the LENT scoring system. Eighty-eight consecutive patients were treated with a rectal block added to the lateral fields. In these patients the posterior margin from the prostate to the block edge was reduced from the standard 15 mm to 7.5 mm for the final 10 Gy which reduced the dose to portions of the anterior rectal wall by approximately 4-5 Gy. Estimates of rates for rectal morbidity were determined by Kaplan-Meier actuarial analyses. Differences in morbidity percentages were evaluated by the Pearson chi square test. Results: Grade 2-3 rectal morbidity developed in 46 of 257 patients (18%) and in the majority of cases consisted of rectal bleeding. No patient has developed grade 4 or 5 rectal morbidity. The actuarial rate of grade 2-3 morbidity is 22% at 24 months and the median

  10. A study on gamma dose rate in Seoul (I)

    International Nuclear Information System (INIS)

    Kim, You Hyun; Kim, Chang Kyun; Choi, Jong Hak; Kim, Jeong Min

    2001-01-01

    This study was conducted to find out gamma dose rate in Seoul, from January to December in 2000, and the following results were achieved : The annual gamma dose rate in Seoul was 17.24 μR/hr as average. The annual gamma dose rate in subway of Seoul was 14.96 μR/hr as average. The highest annual gamma dose rate was Dong-daemon ku. Annual gamma dose rate in Seoul was higher autumn than winter

  11. Radiobiological responses for two cell lines following continuous low dose-rate (CLDR) and pulsed dose rate (PDR) brachytherapy

    International Nuclear Information System (INIS)

    Hanisch, Per Henrik; Furre, Torbjoern; Olsen, Dag Rune; Pettersen, Erik O.

    2007-01-01

    The iso-effective irradiation of continuous low-dose-rate (CLDR) irradiation was compared with that of various schedules of pulsed dose rate (PDR) irradiation for cells of two established human lines, T-47D and NHIK 3025. Complete single-dose response curves were obtained for determination of parameters α and β by fitting of the linear quadratic formula. Sublethal damage repair constants μ and T 1/2 were determined by split-dose recovery experiments. On basis of the acquired parameters of each cell type the relative effectiveness of the two regimens of irradiation (CLDR and PDR) was calculated by use of Fowler's radiobiological model for iso-effect irradiation for repeated fractions of dose delivered at medium dose rates. For both cell types the predicted and observed relative effectiveness was compared at low and high iso-effect levels. The results indicate that the effect of PDR irradiation predicted by Fowler's model is equal to that of CLDR irradiation for both small and large doses with T-47D cells. With NHIK 3025 cells PDR irradiation induces a larger effect than predicted by the model for small doses, while it induces the predicted effect for high doses. The underlying cause of this difference is unclear, but cell-cycle parameters, like G2-accumulation is tested and found to be the same for the two cell lines

  12. Daptomycin versus linezolid for the treatment of vancomycin-resistant enterococcal bacteraemia: implications of daptomycin dose.

    Science.gov (United States)

    Chuang, Y-C; Lin, H-Y; Chen, P-Y; Lin, C-Y; Wang, J-T; Chang, S-C

    2016-10-01

    Treatment options for vancomycin-resistant enterococci (VRE) bloodstream infection are limited. Studies comparing daptomycin or linezolid in treating VRE bloodstream infection have conflicting results and suggest daptomycin underdosing. The responses to different daptomycin doses have not been studied. We conducted a multicentre prospective cohort study to compare linezolid and daptomycin (≥6 mg/kg) for the treatment of VRE bloodstream infection. The primary outcome was 14-day mortality. We used multivariate logistic regression analysis for outcome analysis and a generalized additive model for dose-dependent response estimation. Two hundred twelve patients were included (daptomycin, n = 141; linezolid, n = 71). All-cause 14-day mortality was higher in the daptomycin group (36.9% vs. 21.1%; p 0.03). After adjusting for confounders in logistic regression, mortality was lower in the linezolid group (adjusted odds ratio (aOR), 0.45; 95% confidence interval (CI), 0.21-0.96; p 0.04). The generalized additive model showed that higher-dose daptomycin (≥9 mg/kg) was associated with better survival than lower-dose daptomycin (6-9 mg/kg). Logistic regression showed that linezolid (aOR, 0.36; 95% CI, 0.17-0.79; p 0.01) and higher-dose daptomycin (aOR, 0.26; 95% CI, 0.09-0.74; p 0.01) independently predicted lower mortality compared to lower-dose daptomycin. Linezolid was not superior to higher-dose daptomycin in terms of mortality (aOR, 1.40; 95% CI, 0.45-4.37; p 0.57). Higher-dose daptomycin had lower mortality than lower-dose daptomycin. Despite higher mortality for lower-dose daptomycin than linezolid, linezolid conferred no survival benefit compared to higher-dose daptomycin. Our findings suggest that the recommended daptomycin dose is suboptimal for treating VRE bacteraemia. Copyright © 2016. Published by Elsevier Ltd.

  13. Managing patient dose in digital radiology

    International Nuclear Information System (INIS)

    2014-01-01

    Digital techniques have the potential to improve the practice of radiology but they also risk the overuse of radiation. The main advantages of digital imaging, i.e. wide dynamic range, post processing, multiple viewing options, and electronic transfer and archiving possibilities, are clear but overexposures can occur without an adverse impact on image quality. In conventional radiography, excessive exposure produces a black film. In digital systems, good images are obtained for a large range of doses. It is very easy to obtain (and delete) images with digital fluoroscopy systems, and there may be a tendency to obtain more images than necessary. In digital radiology, higher patient dose usually means improved image quality, so a tendency to use higher patient doses than necessary could occur. Different medical imaging tasks require different levels of image quality, and doses that have no additional benefit for the clinical purpose should be avoided. Image quality can be compromised by inappropriate levels of data compression and/or post processing techniques. All these new challenges should be part of the optimisation process and should be included in clinical and technical protocols. Local diagnostic reference levels should be re-evaluated for digital imaging, and patient dose parameters should be displayed at the operator console. Frequent patient dose audits should occur when digital techniques are introduced. Training in the management of image quality and patient dose in digital radiology is necessary. Digital radiology will involve new regulations and invoke new challenges for practitioners. As digital images are easier to obtain and transmit, the justification criteria should be reinforced. Commissioning of digital systems should involve clinical specialists, medical physicists, and radiographers to ensure that imaging capability and radiation dose management are integrated. Quality control requires new procedures and protocols (visualisation, transmission

  14. Comparison of doses, before and after remedial action

    International Nuclear Information System (INIS)

    Wallo, A. III

    1988-01-01

    The Division of Facility and Site Decommissioning Projects at DOE-Headquarters is evaluating potential doses from vicinity properties before and after remedial action at several sites using the RESRAD computer code. A preliminary review was completed for nineteen Colonie vicinity properties. This review indicated potential doses before remedial action at these sites ranged from about 43 to 2 mrem/year and after remediation between 5 and 0 mrem/year. These estimates indicate the conservatism in the DOE-derived soil decontamination remedial action. Following remedial action, the potential doses are on the order of those being considered to be below regulatory concern by EPA and NRC. The estimates made for these sites are still conservative due to the method used to determine the source term. More realistic assessments of source terms are anticipate dot significantly affect the after-remedial-action doses, possibly lowering them all to below 1 mrem/year. This evaluation is being refined with more realistic estimates of the source term, for all of the Colonie vicinity properties. Once the Colonie vicinity properties are completed, at least three other sites will be evaluated. It is hoped that this information will provide added confidence in the remedial action guidelines and more general acceptance of the guidelines by the EPA and others

  15. Thermoluminescent dosimeters for low dose X-ray measurements

    International Nuclear Information System (INIS)

    Del Sol Fernández, S.; García-Salcedo, R.; Sánchez-Guzmán, D.; Ramírez-Rodríguez, G.; Gaona, E.; León-Alfaro, M.A. de; Rivera-Montalvo, T.

    2016-01-01

    The response of TLD-100, CaSO_4:Dy and LiF:Mg,Cu,P for a range of X-ray low dose was measured. For calibration, the TLDs were arranged at the center of the X-ray field. The dose output of the X-ray machine was determined using an ACCU-Gold. All dosimeters were exposed at the available air kerma values of 14.69 mGy within a field 10×10 cm"2 at 80 cm of SSD. Results of LiF:Mg,Cu,P X-ray irradiated showed 4.8 times higher sensitivity than TLD-100. Meanwhile, TL response of CaSO_4:Dy exposed at the same dose was 5.6 time higher than TLD-100. Experimental results show for low dose X-ray measurements a better linearity for LiF:Mg,Cu,P compared with that of TLD-100. CaSO_4:Dy showed a linearity from 0.1 to 60 mGy - Highlights: • Low dose X-ray doses for personal dosimetry were measured. • Radiation dose (µGy ) for environmental dosimetry were determined. • Scattering radiation dose were measured by TLDs. • Linearity of pair TLD system was successful in the range of microgray. • Pair TLDs composed by CaSO_4:Dy and by LiF:Mg,Cu,P. is suggested for clinical dosimetry.

  16. Demonstration of brachytherapy boost dose-response relationships in glioblastoma multiforme

    International Nuclear Information System (INIS)

    Sneed, Penny K.; Lamborn, Kathleen R.; Larson, David A.; Prados, Michael D.; Malec, Mary K.; McDermott, Michael W.; Weaver, Keith A.; Phillips, Theodore L.; Wara, William M.; Gutin, Philip H.

    1996-01-01

    Purpose: To evaluate brachytherapy dose-response relationships in adults with glioblastoma undergoing temporary 125 I implant boost after external beam radiotherapy. Methods and Materials: Since June 1987, orthogonal radiographs using a fiducial marker box have been used to verify brain implant source positions and generate dose-volume histograms at the University of California, San Francisco. For adults who underwent brachytherapy boost for glioblastoma from June 1987 through December 1992, tumor volumes were reoutlined to ensure consistency and dose-volume histograms were recalculated. Univariate and multivariate analyses of various patient and treatment parameters were performed evaluating for influence of dose on freedom from local failure (FFLF) and actuarial survival. Results: Of 102 implant boosts, 5 were excluded because computer plans were unavailable. For the remaining 97 patients, analyses with adjustment for known prognostic factors (age, KPS, extent of initial surgical resection) and prognostic factors identified on univariate testing (adjuvant chemotherapy) showed that higher minimum brachytherapy tumor dose was strongly associated with improved FFLF (p = 0.001). A quadratic relationship was found between total biological effective dose and survival, with a trend toward optimal survival probability at 47 Gy minimum brachytherapy tumor dose (corresponding to about 65 Gy to 95% of the tumor volume); survival decreased with lower or higher doses. Two patients expired and one requires hospice care because of brain necrosis after brachytherapy doses > 63 Gy to 95% of the tumor volume with 60 Gy to > 18 cm 3 of normal brain. Conclusion: Although higher minimum brachytherapy tumor dose was strongly associated with better local control, a brachytherapy boost dose > 50-60 Gy may result in life-threatening necrosis. We recommend careful conformation of the prescription isodose line to the contrast enhancing tumor volume, delivery of a minimum brachytherapy

  17. Sustained availability of trimethoprim in drinking water to achieve higher plasma sulphonamide-trimethoprim antibacterial activity in broilers.

    Science.gov (United States)

    Sumano, H; Hernandez, L; Gutierrez, L; Bernad-Bernad, M J

    2005-02-01

    (1) In order to make trimethoprim (TMP) available to broilers throughout the day, a sustained release formulation (SRF) of the drug in the form of granules was added to the water tank that supplies drinking water. (2) Broilers were initially dosed with sulphachloropiridazine-TMP (SCP-TMP 5:1) and then further medicated throughout the day, achieving in the end a dose of 30 mg/kg each of SCP and TMP (group A). Group B received a preparation with the same dose of SCP and TMP (1:1) as group A, but administered as a single dose without the SRF of TMP. Group C received the customary SCP-TMP 5:1 preparation (30 and 6 mg/kg, respectively). Water tanks were completely consumed in 3 to 4 h. (3) Broilers were bled at different times and concentration of antibacterial activity in serum determined by correlating the composite antibacterial activity of SCP and TMP with actual concentrations of these drugs by means of a microbiological agar diffusion assay. (4) Time vs serum concentrations of activity were higher in group B; the increments in the maximum serum concentration for group B over groups A and C being 39 and 67%, respectively. (5) However, the sustained concentration of activity over time, measured as the area under the cu)rve, was highest in group A. Group B had higher values for area under the curve than group C. (6) An additional dose of TMP to achieve 30 mg/kg of both SCP and TMP improves the serum concentration of this combination over the customary 5:1 proportion. The best values for sustaining antibacterial activity were obtained using a 1:1 ratio as in group A. The use of a SRF as in group A may translate into better clinical results.

  18. Radiation Therapy for Bone Metastases from Hepatocellular Carcinoma: Effect of Radiation Dose Escalation

    International Nuclear Information System (INIS)

    Kim, Tae Gyu; Park, Hee Chul; Lim, Do Hoon

    2011-01-01

    To evaluate the extent of pain response and objective response to palliative radiotherapy (RT) for bone metastases from hepatocellular carcinoma according to RT dose. From January 2007 to June 2010, palliative RT was conducted for 103 patients (223 sites) with bone metastases from hepatocellular carcinoma. Treatment sites were divided into the high RT dose and low RT dose groups by biologically effective dose (BED) of 39 Gy10. Pain responses were evaluated using the numeric rating scale. Pain scores before and after RT were compared and categorized into 'Decreased', 'No change' and 'increased'. Radiological objective responses were categorized into complete response, partial response, stable disease and progression using modified RECIST (Response Evaluation Criteria In Solid Tumors) criteria; the factors predicting patients' survival were analyzed. The median follow-up period was 6 months (range, 0 to 46 months), and the radiologic responses existed in 67 RT sites (66.3%) and 44 sites (89.8%) in the high and low RT dose group, respectively. A dose-response relationship was found in relation to RT dose (p=0.02). Pain responses were 75% and 65% in the high and low RT dose groups, respectively. However, no statistical difference in pain response was found between the two groups (p=0.24). There were no differences in the toxicity profiles between the high and low RT dose groups. Median survival from the time of bone metastases diagnosis was 11 months (range, 0 to 46 months). The Child-Pugh classification at the time of palliative RT was the only significant predictive factor for patient survival after RT. Median survival time was 14 months under Child-Pugh A and 2 months under Child-Pugh B and C. The rate of radiologic objective response was higher in the high RT dose group. Palliative RT with a high dose would provide an improvement in patient quality of life through enhanced tumor response, especially in patients with proper liver function.

  19. Optimal bladder filling during high-dose-rate intracavitary brachytherapy for cervical cancer: a dosimetric study

    Directory of Open Access Journals (Sweden)

    Umesh Mahantshetty

    2017-04-01

    Full Text Available Purpose: The aim of this study is to compare 3D dose volume histogram (DVH parameters of bladder and other organs at risk with different bladder filling protocol during high-dose-rate intracavitary brachytherapy (HDR-ICBT in cervical cancer, and to find optimized bladder volume. Material and methods : This dosimetric study was completed with 21 patients who underwent HDR-ICBT with computed tomography/magnetic resonance compatible applicator as a routine treatment. Computed tomography planning was done for each patient with bladder emptied (series 1, after 50 ml (series 2, and 100 ml (series 3 bladder filling with a saline infusion through the bladder catheter. Contouring was done on the Eclipse Planning System. 7 Gy to point A was prescribed with the standard loading patterns. Various 3D DVH parameters including 0.1 cc, 1 cc, 2 cc doses and mean doses to the OAR’s were noted. Paired t-test was performed. Results : The mean (± SD bladder volume was 64.5 (± 25 cc, 116.2 (± 28 cc, and 172.9 (± 29 cc, for series 1, 2, and 3, respectively. The 0.1 cm 3 ,1 cm 3 , 2 cm 3 mean bladder doses for series 1, series 2, and series 3 were 9.28 ± 2.27 Gy, 7.38 ± 1.72 Gy, 6.58 ± 1.58 Gy; 9.39 ± 2.28 Gy, 7.85 ± 1.85 Gy, 7.05 ± 1.59 Gy, and 10.09 ± 2.46 Gy, 8.33 ± 1.75 Gy, 7.6 ± 1.55 Gy, respectively. However, there was a trend towards higher bladder doses in series 3. Similarly, for small bowel dose 0.1 cm 3 , 1 cm 3 , and 2 cm 3 in series 1, 2, and 3 were 5.44 ± 2.2 Gy, 4.41 ± 1.84 Gy, 4 ± 1.69 Gy; 4.57 ± 2.89 Gy, 3.78 ± 2.21 Gy, 3.35 ± 2.02 Gy, and 4.09 ± 2.38 Gy, 3.26 ± 1.8 Gy, 3.05 ± 1.58 Gy. Significant increase in small bowel dose in empty bladder (series 1 compared to full bladder (series 3 (p = 0.03 was noted. However, the rectal and sigmoid doses were not significantly affected with either series. Conclusions : Bladder filling protocol with 50 ml and 100 ml was well tolerated and achieved a reasonably reproducible bladder volume

  20. Dose-volume effects in the rat cervical spinal cord after proton irradiation

    International Nuclear Information System (INIS)

    Bijl, Hendrik P.; Vuijk, Peter van; Coppes, Rob P.; Schippers, Jacobus M.; Konings, Antonius W.T.; Kogel, Albert J. van der

    2002-01-01

    Purpose: To estimate dose-volume effects in the rat cervical spinal cord with protons. Methods and Materials: Wistar rats were irradiated on the cervical spinal cord with a single fraction of unmodulated protons (150-190 MeV) using the shoot through method, which employs the plateau of the depth-dose profile rather than the Bragg peak. Four different lengths of the spinal cord (2, 4, 8, and 20 mm) were irradiated with variable doses. The endpoint for estimating dose-volume effects was paralysis of fore or hind limbs. Results: The results obtained with a high-precision proton beam showed a marginal increase of ED 50 when decreasing the irradiated cord length from 20 mm (ED 50 = 20.4 Gy) to 8 mm (ED 50 = 24.9 Gy), but a steep increase in ED 50 when further decreasing the length to 4 mm (ED 50 = 53.7 Gy) and 2 mm (ED 50 = 87.8 Gy). These results generally confirm data obtained previously in a limited series with 4-6-MV photons, and for the first time it was possible to construct complete dose-response curves down to lengths of 2 mm. At higher ED 50 values and shorter lengths irradiated, the latent period to paralysis decreased from 125 to 60 days. Conclusions: Irradiation of variable lengths of rat cervical spinal cord with protons showed steeply increasing ED 50 values for lengths of less than 8 mm. These results suggest the presence of a critical migration distance of 2-3 mm for cells involved in regeneration processes

  1. Thymocyte apoptosis in response to low-dose radiation

    International Nuclear Information System (INIS)

    Shu-Zheng, Liu; Ying-Chun, Zhang; Ying, Mu; Xu, Su; Jian-Xiang, Liu

    1996-01-01

    Thymocyte apoptosis was assessed by counting apoptotic bodies with flow cytometry (FCM) and measuring DNA fragmentation with fluorescence spectrophotometry (FSP). J-shaped dose-response curves were obtained after both whole-body irradiation (WBI) of mice and in vitro irradiation of EL4 cells with doses ranging from 0.025 to 4 Gy X-rays. There was a significant reduction of apoptosis rate to below control level with doses within 0.2 Gy, and a dose-dependent increase in apoptosis with doses above 0.5 Gy. When thymocytes were cultured 24 h after WBI with 75 mGy X-rays in complete RPMI 1640 medium, a reduction in apoptosis was observed in the course of incubation for 72 h, and the presence of Con A in the medium accentuated this reduction in a dose- and time-dependent manner. The implications of these observations and the possible molecular mechanisms for future studies are proposed

  2. Survey of computed tomography doses in head and chest protocols; Levantamento de doses em tomografia computadorizada em protocolos de cranio e torax

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Giordana Salvi de; Froner, Ana Paula Pastre; Silva, Ana Maria Marques da, E-mail: giordana.souza@acad.pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil). Faculdade de Fisica. Nucleo de Pesquisa em Imagens Medicas

    2016-07-01

    Surveys of dose estimates from different medical imaging modalities highlight significant variations between health care facilities for the same examination and similar patient groups. To ensure that doses are optimized, diagnostic reference levels (DRL) must be determined, allowing the identification of procedures that are out of optimal standards. The aim of this study is to present a retrospective survey of dose indicators in head and chest CT scans, in terms of Dose-Length Product (DLP) and effective dose for adult and pediatric patients, comparing them with DRL in the literature. The study was performed with data from 293 patients submitted to computed tomography of the skull and 146 of the thorax, divided into age groups (0⊣ 1; 1⊣ 5; 5⊣ 10; 10⊣ 15; >15. For head, DLP third percentiles and effective doses are mostly higher than DRL in literature, mainly for children from 10⊣15 years (800 mGy.cm; 3,3 mSv) and 5⊣ 10 years (969 mGy.cm; 2,6 mSv). For thorax examination, although DLP are close to the DRL in literature, high variability is revealed, and the effective doses are higher for all ages. In conclusion, the survey of dose indicators in computed tomography examinations and their comparison with DRL constitute an important tool for the optimization of doses in patients. (author)

  3. Analysis of CT radiation dose based on radiation-dose-structured reports

    International Nuclear Information System (INIS)

    Wang Weipeng; Zhang Yi; Zhang Menglong; Zhang Dapeng; Song Shaojuan

    2014-01-01

    Objective: To analyse the CT radiation dose statistically using the standardized radiation-dose-structured report (RDSR) of digital imaging and communications in medicine (DICOM). Methods: Using the self-designed software, 1230 RDSR files about CT examination were obtained searching on the picture archiving and communication system (PACS). The patient dose database was established by combination of the extracted relevant information with the scanned sites. The patients were divided into adult group (over 10 years) and child groups (0-1 year, 1-5 years, 5-10 years) according to the age. The average volume CT dose index (CTDI vol ) and dose length product (DLP) of all scans were recorded respectively, and then the effective dose (E) was estimated. The DLP value at 75% quantile was calculated and compared with the diagnostic reference level (DRL). Results: In adult group, CTDI vol and DLP values were moderately and positively correlated (r = 0.41), the highest E was observed in upper abdominal enhanced scan, and the DLP value at 75% quantile was 60% higher than DRL. In child group, their CTDI vol in group of 5-10 years was greater than that in groups of 0-1 and 1-5 years (t = 2.42, 2.04, P < 0.05); the DLP value was slightly and positively correlated with the age (r = 0.16), while E was moderately and negatively correlated with the age (r = -0.48). Conclusions: It is a simple and efficient method to use RDSR to obtain the radiation doses of patients. With the popularization of the new equipment and the application of regionalized medical platform, RDSR would become the main tool for the dosimetric level surveying and individual dose recording. (authors)

  4. Warfarin Dosing Algorithms Underpredict Dose Requirements in Patients Requiring ≥7 mg Daily: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Saffian, S M; Duffull, S B; Wright, Dfb

    2017-08-01

    There is preliminary evidence to suggest that some published warfarin dosing algorithms produce biased maintenance dose predictions in patients who require higher than average doses. We conducted a meta-analysis of warfarin dosing algorithms to determine if there exists a systematic under- or overprediction of dose requirements for patients requiring ≥7 mg/day across published algorithms. Medline and Embase databases were searched up to September 2015. We quantified the proportion of over- and underpredicted doses in patients whose observed maintenance dose was ≥7 mg/day. The meta-analysis included 47 evaluations of 22 different warfarin dosing algorithms from 16 studies. The meta-analysis included data from 1,492 patients who required warfarin doses of ≥7 mg/day. All 22 algorithms were found to underpredict warfarin dosing requirements in patients who required ≥7 mg/day by an average of 2.3 mg/day with a pooled estimate of underpredicted doses of 92.3% (95% confidence interval 90.3-94.1, I 2 = 24%). © 2017 American Society for Clinical Pharmacology and Therapeutics.

  5. Occupational dose assessment in interventional cardiology in Serbia

    International Nuclear Information System (INIS)

    Kaljevic, J.; Ciraj-Bjelac, O.; Stankovic, J.; Arandjic, D.; Bozovic, P.; Antic, V.

    2016-01-01

    The objective of this work is to assess the occupational dose in interventional cardiology in a large hospital in Belgrade, Serbia. A double-dosimetry method was applied for the estimation of whole-body dose, using thermoluminescent dosemeters, calibrated in terms of the personal dose equivalent H p (10). Besides the double-dosimetry method, eye dose was also estimated by means of measuring ambient dose equivalent, H*(10), and doses per procedure were reported. Doses were assessed for 13 physicians, 6 nurses and 10 radiographers, for 2 consequent years. The maximum annual effective dose assessed was 4.3, 2.1 and 1.3 mSv for physicians, nurses and radiographers, respectively. The maximum doses recorded by the dosemeter worn at the collar level (over the apron) were 16.8, 11.9 and 4.5 mSv, respectively. This value was used for the eye lens dose assessment. Estimated doses are in accordance with or higher than annual dose limits for the occupational exposure. (authors)

  6. Investigation of percentage depth dose and dose rate dependence of PAGAT polymer gel dosimeter for photon beams using MRI technique

    International Nuclear Information System (INIS)

    Azadbakht, B.; Hadad, K.; Zahmatkesh, M. H.

    2010-01-01

    In this work, the investigation of the normoxic Pagan polymer-gel dosimeter percentage depth dose and it's dose rate dependence has been made. Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylene-bis-acrylamide(bis), 4.5% acrylamide, 5% gelatine, 5 m M tetrakis (hydroxymethyl) phosphonium chloride, 0.01 m M hydroquinone and 86% HPLC(Water). Irradiation of vials was performed using photon beams of Co-60 therapy unit and an Elec ta linear accelerator. Gel dosimeters were imaged in a Siemens Symphony 1.5 Tesla clinical MRI scanner using a head coil. Post-manufacture irradiation and post imaging times were both selected to be 1 day. For determining the percentage depth dose of the Pagan gel it was found that at the depth of 21 cm, the percentage depth dose for 1.25 MeV γ-ray photons of 60 Co and for 4,6 and 18 MV x-ray photons of Elec ta linear accelerator, are 48%, 52%, 57.3% and 59.73%, respectively. Thus, in the case of the higher energy photon beams, a higher dose can he delivered. to deep-seated tumors. The dose rate dependence of percentage depth dose was studied for 6 MV x-ray photons with the use of dose rates of 80, 160, 240, 320, 400 and 480 c Gy/min. No trend in polymer-gel dosimeter 1/T 2 dependence was found on the mean dose rate and energy for the photon beams.

  7. Individual radiation doses. Annual report 1995

    International Nuclear Information System (INIS)

    Bergman, L.

    1995-05-01

    During the year we measured whole body doses on 10226 bearers, distributed as follows: 0-0,5 mSv on 8816 persons, 0,6-1,0 mSv on 693 persons, 1,1-5,0 on 678 persons, >5 mSv on 39 persons. At higher dose than 4 mSv/4 weeks, the reason to the irradiation will be investigated. 2 figs, 2 tabs

  8. Performances of Dose Measurement of Commercial Electronic Dosimeters using Geiger Muller Tube and PIN Diode

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Hyunjun; Kim, Chankyu; Kim, Yewon; Kim, Giyoon; Cho, Gyuseong [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2014-05-15

    There are two categories in personal dosimeters, one is passive type dosimeter such as TLD (thermoluminescence dosimeter) and the other is active type dosimeter such as electronic dosimeter can show radiation dose immediately while TLD needs long time to readout its data by heating process. For improving the reliability of measuring dose for any energy of radiations, electronic dosimeter uses energy filter by metal packaging its detector using aluminum or copper, but measured dose of electronic dosimeter with energy filter cannot be completely compensated in wide radiation energy region. So, in this paper, we confirmed the accuracy of dose measurement of two types of commercial EPDs using Geiger Muller tube and PIN diode with CsI(Tl) scintillator in three different energy of radiation field. The experiment results for Cs-137 was almost similar with calculation value in the results of both electronic dosimeters, but, the other experiment values with Na-22 and Co-60 had higher error comparing with Cs-137. These results were caused by optimization of their energy filters. The optimization was depending on its thickness of energy filter. So, the electronic dosimeters have to optimizing the energy filter for increasing the accuracy of dose measurement or the electronic dosimeter using PIN diode with CsI(Tl) scintillator uses the multi-channel discriminator for using its energy information.

  9. Ir-192 HDR transit dose and radial dose function determination using alanine/EPR dosimetry

    International Nuclear Information System (INIS)

    Calcina, Carmen S Guzman; Almeida, Adelaide de; Rocha, Jose R Oliveira; Abrego, Felipe Chen; Baffa, Oswaldo

    2005-01-01

    Source positioning close to the tumour in high dose rate (HDR) brachytherapy is not instantaneous. An increment of dose will be delivered during the movement of the source in the trajectory to its static position. This increment is the transit dose, often not taken into account in brachytherapeutic treatment planning. The transit dose depends on the prescribed dose, number of treatment fractions, velocity and activity of the source. Combining all these factors, the transit dose can be 5% higher than the prescribed absorbed dose value (Sang-Hyun and Muller-Runkel, 1994 Phys. Med. Biol. 39 1181-8, Nath et al 1995 Med. Phys. 22 209-34). However, it cannot exceed this percentage (Nath et al 1995). In this work, we use the alanine-EPR (electron paramagnetic resonance) dosimetric system using analysis of the first derivative of the signal. The transit dose was evaluated for an HDR system and is consistent with that already presented for TLD dosimeters (Bastin et al 1993 Int. J. Radiat. Oncol. Biol. Phys. 26 695-702). Also using the same dosimetric system, the radial dose function, used to evaluate the geometric dose degradation around the source, was determined and its behaviour agrees better with those obtained by Monte Carlo simulations (Nath et al 1995, Williamson and Nath 1991 Med. Phys. 18 434-48, Ballester et al 1997 Med. Phys. 24 1221-8, Ballester et al 2001 Phys. Med. Biol. 46 N79-90) than with TLD measurements (Nath et al 1990 Med. Phys. 17 1032-40)

  10. Dose-ranging pharmacokinetics of colistin methanesulphonate (CMS) and colistin in rats following single intravenous CMS doses.

    Science.gov (United States)

    Marchand, Sandrine; Lamarche, Isabelle; Gobin, Patrice; Couet, William

    2010-08-01

    The aim of this study was to evaluate the effect of colistin methanesulphonate (CMS) dose on CMS and colistin pharmacokinetics in rats. Three rats per group received an intravenous bolus of CMS at a dose of 5, 15, 30, 60 or 120 mg/kg. Arterial blood samples were drawn at 0, 5, 15, 30, 60, 90, 120, 150 and 180 min. CMS and colistin plasma concentrations were determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The pharmacokinetic parameters of CMS and colistin were calculated by non-compartmental analysis. Linear relationships were observed between CMS and colistin AUCs to infinity and CMS doses, as well as between CMS and colistin C(max) and CMS doses. CMS and colistin pharmacokinetics were linear for a range of colistin concentrations covering the range of values encountered and recommended in patients even during treatment with higher doses.

  11. Oral sodium phenylbutyrate in patients with recurrent malignant gliomas: a dose escalation and pharmacologic study.

    Science.gov (United States)

    Phuphanich, Surasak; Baker, Sharyn D; Grossman, Stuart A; Carson, Kathryn A; Gilbert, Mark R; Fisher, Joy D; Carducci, Michael A

    2005-04-01

    We determined the maximum tolerated dose (MTD), toxicity profile, pharmacokinetic parameters, and preliminary efficacy data of oral sodium phenylbutyrate (PB) in patients with recurrent malignant gliomas. Twenty-three patients with supratentorial recurrent malignant gliomas were enrolled on this dose escalation trial. Four dose levels of PB were studied: 9, 18, 27, and 36 g/day. Data were collected to assess toxicity, response, survival, and pharmacokinetics. All PB doses of 9, 18, and 27 g/day were well tolerated. At 36 g/day, two of four patients developed dose-limiting grade 3 fatigue and somnolence. At the MTD of 27 g/day, one of seven patients developed reversible grade 3 somnolence. Median survival from time of study entry was 5.4 months. One patient had a complete response for five years, and no partial responses were noted, which yielded an overall response rate of 5%. Plasma concentrations of 706, 818, 1225, and 1605 muM were achieved with doses of 9, 18, 27, and 36 g/day, respectively. The mean value for PB clearance in this patient population was 22 liters/h, which is significantly higher than the 16 liters/h reported in patients with other malignancies who were not receiving P450 enzyme-inducing anticonvulsant drugs (P = 0.038). This study defines the MTD and recommended phase 2 dose of PB at 27 g/day for heavily pretreated patients with recurrent gliomas. The pharmacology of PB appears to be affected by concomitant administration of P450-inducing anticonvulsants.

  12. Low, fixed dose defibrotide in management of hepatic veno-occlusive disease post stem cell transplantation.

    Science.gov (United States)

    Bagal, Bhausaheb; Chandrasekharan, Arun; Chougle, Aliya; Khattry, Navin

    2018-03-01

    Hepatic veno-occlusive disease (VOD) is well recognized potentially serious regimen-related toxicity seen after stem cell transplantation. Severe VOD is associated with poor long-term outcomes with very high mortality. Besides supportive care, only defibrotide has been found to be effective in the management of VOD. The recommended dose of defibrotide is 25mg/kg/d but there has been no classical dose finding study done for this drug. A higher dose of defibrotide is associated with increased risk of bleeding and this drug is prohibitively expensive. We report our experience of using fixed low dose of defibrotide in patients with VOD. We retrospectively evaluated 511 patients who underwent stem cell transplant at our center from November 2007 and December 2015. All patients received ursodeoxycholic acid as VOD prophylaxis. Modified Seattle criterion was used for diagnosis and severity grading of VOD. Patients developing VOD were initially treated with furosemide and adequate analgesia. Defibrotide was started within 12 to 24 hours of diagnosis of VOD. All adult patients received defibrotide at a fixed dose of 200mg twice daily while two children were given dose of 100mg and 50mg twice daily. Nine (1.7%) of our patients developed VOD. Daily dose of defibrotide ranged from 5mg/kg/d to 20mg/kg/d till resolution of VOD. All patients had complete resolution of VOD. None of our patients required ventilator support or dialysis. No episodes of bleeding were observed. No dose response relationship was observed between defibrotide dose and time to resolution of VOD. Low fixed dose defibrotide initiated early seems to be effective and safe in treatment of VOD. This is relevant in a resource limited setting and warrants prospective evaluation. Copyright © 2017 King Faisal Specialist Hospital & Research Centre. Published by Elsevier B.V. All rights reserved.

  13. Radiation dose to the lens and cataract formation

    International Nuclear Information System (INIS)

    Henk, J.M.; Whitelocke, R.A.F.; Warrington, A.P.; Bessell, E.M.

    1993-01-01

    The purpose of this work was to determine the radiation tolerance of the lens of the eye and the incidence of radiation-induced lens changes in patients treated by fractionated supervoltage radiation therapy for orbital tumors. Forty patients treated for orbital lymphoma and pseudotumor with tumor doses of 20--40 Gy were studied. The lens was partly shielded using lead cylinders in most cases. The dose to the germinative zone of the lens was estimated by measurements in a tissue equivalent phantom using both film densitometry and thermoluminescent dosimetry. Opthalmological examination was performed at 6 monthly intervals after treatment. The lead shield was found to reduce the dose to the germinative zone of the lens to between 36--50% of the tumor dose for Cobalt beam therapy, and to between 11--18% for 5 MeV x-rays. Consequently, the lens doses were in the range 4.5--30 Gy in 10--20 fractions. Lens opacities first appeared from between 3 and 9 years after irradiation. Impairment of visual acuity ensued in 74% of the patients who developed lens opacities. The incidence of lens changes was strongly dose-related. None was seen after doses of 5 Gy or lower, whereas doses of 16.5 Gy or higher were all followed by lens opacities which impaired visual acuity. The largest number of patients received a maximum lens dose of 15 Gy; in this group the actuarial incidence of lens opacities at 8 years was 57% with visual impairment in 38%. The adult lens can tolerate a total dose of 5 Gy during a fractionated course of supervoltage radiation therapy without showing any changes. Doses of 16.5 Gy or higher will almost invariably lead to visual impairment. The dose which causes a 50% probability of visual impairment is approximately 15 Gy. 10 refs., 4 figs., 1 tab

  14. Radiation Dose from Voiding Cystourethrography (VCUG) Examination in Children

    International Nuclear Information System (INIS)

    Siriwiladluk, T.; Krisanachinda, A.

    2012-01-01

    Introduction: The purpose of this study is to determine entrance skin dose (ESD) from fluoroscopy and radiography procedures in voiding cystourethrography (VCUG) studies of pediatric patients by dose-area product (DAP) recording. Methods: Radiation doses received by 70 patients underwent VCUG procedures were determined by the DAP Meter, Wellh?fer Dosimetrie GmbH, Germany) directly coupled to the x-ray tube window (Philips Omni Diagnost Eleva) and an electrometer connected to a computer for data collection. The study revealed the radiation dose for VCUG and the baseline data on the entrance skin dose, ESD, dose area-product (DAP) and the effective dose, E, to establish local reference dose levels for VCUG in pediatric patients. Results: The mean(minimum-maximum) ESD, DAP and the effective dose of pediatric patients in 4 age ranges were 3.41(1-9) mGy, 46.58 (21.90-158.90) cGycm 2 and 0.10(0.05-0.33) mSv for 0- 1 years, 6.80(2-16) mGy, 115.55 (20.70-258.70)cGycm 2 and 0.24(0.04-0.54) mSv for >1-5 years, 11.76 (3-23) mGy, 292.28 (88.90-593.50)cGycm 2 and 0.61(0.19-1.25) mSv for >5-10 years, and 20.50(10-42) mGy, 575.98(255.60-1247.80) cGycm 2 and 1.12(0.54-2.62) mSv for >10-15 years respectively. Discussion: The dose levels for VCUG as recommended by the national reference doses (NRDs) of UK are classified at patient age of 0-1 years, 90 cGy.cm 2 , >1-5 years, 110 cGy.cm 2 , >5-10 years, 210 cGy.cm 2 and >10-15 years, 470 cGy.cm 2 respectively. Conclusions: The mean DAP of pediatric patients were higher than the dose level as recommended by NRD at the age range >1-5, >5-10 and >10-15 years. The limitation in this study was the non uniform in the number of patients at the higher age. Attempts could be made to lower the radiation dose to avoid the higher risk of developing radiation-induced cancer in children. (author)

  15. Safety and pharmacodynamics of venetoclax (ABT-199) in a randomized single and multiple ascending dose study in women with systemic lupus erythematosus.

    Science.gov (United States)

    Lu, P; Fleischmann, R; Curtis, C; Ignatenko, S; Clarke, S H; Desai, M; Wong, S L; Grebe, K M; Black, K; Zeng, J; Stolzenbach, J; Medema, J K

    2018-02-01

    Objective The anti-apoptotic protein B-cell lymphoma 2 (Bcl-2) may contribute to the pathogenesis of systemic lupus erythematosus. The safety, tolerability, and pharmacodynamics of the selective Bcl-2 inhibitor venetoclax (ABT-199) were assessed in women with systemic lupus erythematosus. Methods A phase 1, double-blind, randomized, placebo controlled study evaluated single ascending doses (10, 30, 90, 180, 300, and 500 mg) and multiple ascending doses (2 cycles; 30, 60, 120, 240, 400, and 600 mg for 1 week, and then 3 weeks off per cycle) of orally administered venetoclax. Eligible participants were aged 18-65 years with a diagnosis of systemic lupus erythematosus for 6 months or more receiving stable therapy for systemic lupus erythematosus (which could have included corticosteroids and/or stable antimalarials). Results All patients (48/48) completed the single ascending dose, 25 continued into the multiple ascending dose, and 44/50 completed the multiple ascending dose; two of the withdrawals (venetoclax 60 mg and 600 mg cohorts) were due to adverse events. Adverse event incidences were slightly higher in the venetoclax groups compared with the placebo groups, with no dose dependence. There were no serious adverse events with venetoclax. The most common adverse events were headache, nausea, and fatigue. Venetoclax 600 mg multiple ascending dose treatment depleted total lymphocytes and B cells by approximately 50% and 80%, respectively. Naive, switched memory, and memory B-cell subsets enriched in autoreactive B cells exhibited dose-dependent reduction of up to approximately 80%. There were no consistent or marked changes in neutrophils, natural killer cells, hemoglobin, or platelets. Conclusions Venetoclax was generally well tolerated in women with systemic lupus erythematosus and reduced total lymphocytes and disease-relevant subsets of antigen-experienced B cells. Registration ClinicalTrials.gov: NCT01686555.

  16. Effects of low priming dose irradiation on cell cycle arrest of HepG2 cells caused by high dose irradiation

    International Nuclear Information System (INIS)

    Xia Jingguang; Jin Xiaodong; Chinese Academy of Sciences, Beijing; Li Wenjian; Wang Jufang; Guo Chuanling; Gao Qingxiang

    2005-01-01

    Human hepatoma cells hepG2 were irradiated twice by 60 Co γ-rays with a priming dose of 5 cGy and a higher dose of 3 Gy performed 4h or 8h after the low dose irradiation. Effects of the priming dose irradiation on cell cycle arrest caused by high dose were examined with flow cytometry. Cells in G 2 /M phase accumulated temporarily after the 5 cGy irradiation, and proliferation of tumor cells was promoted significantly by the low dose irradiation. After the 3 Gy irradiation, G 2 phase arrest occurred, and S phase delayed temporally. In comparison with 3 kGy irradiation only, the priming dose delivered 4h prior to the high dose irradiation facilitated accumulation of hepG2 cells in G 2 /M phase, whereas the priming dose delivered 8h prior to the high dose irradiation helped the cells to overcome G 2 arrest. It was concluded that effects of the priming dose treatment on cell cycle arrest caused by high dose irradiation were dependent on time interval between the two irradiations. (authors)

  17. A study on seasonal variations of indoor gamma dose in Bangladesh

    International Nuclear Information System (INIS)

    Miah, M. Idrish

    2005-01-01

    Monthly variation of gamma dose rate measured in indoor air of buildings of Bangladesh was found to vary cosinusoidally through a period of 1 year. Significant seasonal variations were observed. Maximum dose rate, however, was observed in January and a minimum in July. Dose rate in January was 32% higher than the annual average, whereas dose rate in July was 50% lower. Seasonally varied ventilation and air exchange rates of the houses might play an important role in the observed variation. The average reduction with respect to winter dose was 59% in summer. Because of lower ventilation and air exchange rates between indoor and outdoor atmosphere, it is expected that the indoor dose rate would be higher in basements than that of upper floors. Monthly dose rate was also found to be influenced by the meteorological conditions. Correlations between dose rate and temperature (r 2 =0.85), rainfall (r=-0.83) and atmospheric pressure (r=0.92) were obtained, but no significant correlation (r=-0.45) was seen between dose rate and humidity. The results show that the seasonal variations of indoor dose rates should be taken into account to estimate annual effective dose equivalent. (author)

  18. Missed doses of oral antihyperglycemic medications in US adults with type 2 diabetes mellitus: prevalence and self-reported reasons.

    Science.gov (United States)

    Vietri, Jeffrey T; Wlodarczyk, Catherine S; Lorenzo, Rose; Rajpathak, Swapnil

    2016-09-01

    Adherence to antihyperglycemic medication is thought to be suboptimal, but the proportion of patients missing doses, the number of doses missed, and reasons for missing are not well described. This survey was conducted to estimate the prevalence of and reasons for missed doses of oral antihyperglycemic medications among US adults with type 2 diabetes mellitus, and to explore associations between missed doses and health outcomes. The study was a cross-sectional patient survey. Respondents were contacted via a commercial survey panel and completed an on-line questionnaire via the Internet. Respondents provided information about their use of oral antihyperglycemic medications including doses missed in the prior 4 weeks, personal characteristics, and health outcomes. Weights were calculated to project the prevalence to the US adult population with type 2 diabetes mellitus. Outcomes were compared according to number of doses missed in the past 4 weeks using bivariate statistics and generalized linear models. Approximately 30% of adult patients with type 2 diabetes mellitus reported missing or reducing ≥1 dose of oral antihyperglycemic medication in the prior 4 weeks. Accidental missing was more commonly reported than purposeful skipping, with forgetting the most commonly reported reason. The timing of missed doses suggested respondents had also forgotten about doses missed, so the prevalence of missed doses is likely higher than reported. Outcomes were poorer among those who reported missing three or more doses in the prior 4 weeks. A substantial number of US adults with type 2 diabetes mellitus miss doses of their oral antihyperglycemic medications.

  19. Determination of the secondary energy from the electron beam with a flattening foil by computer. Percentage depth dose curve fitting using the specific higher order polynomial

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, H [Kyushu Univ., Beppu, Oita (Japan). Inst. of Balneotherapeutics

    1980-09-01

    A computer program written in FORTRAN is described for determining the secondary energy of the electron beam which passed through a flattening foil, using a time-sharing computer service. The procedure of this program is first to fit the specific higher order polynomial to the measured percentage depth dose curve. Next, the practical range is evaluated by the point of intersection R of the line tangent to the fitted curve at the inflection point P and the given dose E, as shown in Fig. 2. Finally, the secondary energy corresponded to the determined practical range can be obtained by the experimental equation (2.1) between the practial range R (g/cm/sup 2/) and the electron energy T (MeV). A graph for the fitted polynomial with the inflection points and the practical range can be plotted on a teletype machine by request of user. In order to estimate the shapes of percentage depth dose curves correspond to the electron beams of different energies, we tried to find some specific functional relationships between each coefficient of the fitted seventh-degree equation and the incident electron energies. However, exact relationships could not be obtained for irreguarity among these coefficients.

  20. Neuropsychological function in adults after high dose fractionated radiation therapy of skull base tumors

    International Nuclear Information System (INIS)

    Glosser, Guila; McManus, Pat; Munzenrider, John; Austin-Seymour, Mary; Fullerton, Barbara; Adams, Judy; Urie, Marcia M.

    1997-01-01

    Purpose: To evaluate the long term effects of high dose fractionated radiation therapy on brain functioning prospectively in adults without primary brain tumors. Methods and Materials: Seventeen patients with histologically confirmed chordomas and low grade chondrosarcomas of the skull base were evaluated with neuropsychological measures of intelligence, language, memory, attention, motor function and mood following surgical resection/biopsy of the tumor prior to irradiation, and then at about 6 months, 2 years and 4 years following completion of treatment. None received chemotherapy. Results: In the patients without tumor recurrence or radiation necrosis, there were no indications of adverse effects on cognitive functioning in the post-acute through the late stages after brain irradiation. Even in patients who received doses of radiation up to 66 Cobalt Gy equivalent through nondiseased (temporal lobe) brain tissue, memory and cognitive functioning remained stable for up to 5 years after treatment. A mild decline in psycho-motor speed was seen in more than half of the patients, and motor slowing was related to higher radiation doses in midline and temporal lobe brain structures. Conclusion: Results suggest that in adults, tolerance for focused radiation is relatively high in cortical brain structures

  1. 8-MOP PUVA for psoriasis: a comparison of a minimal phototoxic dose-based regimen with a skin-type approach

    Energy Technology Data Exchange (ETDEWEB)

    Collins, P.; Wainwright, N.J.; Amorim, I.; Lakshmipathi, T.; Ferguson, J. [Ninewells Hospital and Medical School, Dundee (United Kingdom)

    1996-08-01

    Two ultraviolet A (UVA) regimens for oral 8-methoxypsoralen (8-MOP) photochemotherapy (PUVA) for moderate/severe chronic plaque psoriasis using a half-body study technique were compared. Each patient received both regimens. A higher-dose regimen based on minimal phototoxic dose (MPD) with percentage incremental increases was given to one-half of the body. The other half received a lower dose regimen based on skin type with fixed incremental UVA increases. Patients were treated twice weekly. Symmetrical plaques were scored to determine the rate of resolution with each regimen. In addition, the number of treatments, cumulative UVA dose and number of days in treatment to achieve overall clearance were recorded. Patients were reviewed monthly for one year to record remission data. Thirty-three patients completed the study. Both regimens were effective and well tolerated. With the MPD-based approach, number of exposures was significantly less for patients with skin types I and II but not III. Although the cumulative UVA dose was higher with the MPD regimen for all skin types studied, the reduced number of exposures required for clearance for skin types I and II but not III, combined with the security of individualized MPD testing, has practical attractions. MPD testing also identified five patients who required an increased psoralen dose and six patients who required a reduction of the initial UVA dose with the skin type regimen. Forty-two percent were still clear 1 year after treatment and there was no significant difference in the number of days in remission between the regimens for those whose psoriasis had recurred. The reduction in the number of exposures required for clearance with the MPD-based regimen may be safer and more cost effective in the long term. (author).

  2. Variable effects of high-dose adrenaline relative to standard-dose adrenaline on resuscitation outcomes according to cardiac arrest duration.

    Science.gov (United States)

    Jeung, Kyung Woon; Ryu, Hyun Ho; Song, Kyung Hwan; Lee, Byung Kook; Lee, Hyoung Youn; Heo, Tag; Min, Yong Il

    2011-07-01

    Adjustment of adrenaline (epinephrine) dosage according to cardiac arrest (CA) duration, rather than administering the same dose, may theoretically improve resuscitation outcomes. We evaluated variable effects of high-dose adrenaline (HDA) relative to standard-dose adrenaline (SDA) on resuscitation outcomes according to CA duration. Twenty-eight male domestic pigs were randomised to the following 4 groups according to the dosage of adrenaline (SDA 0.02 mg/kg vs. HDA 0.2mg/kg) and duration of CA before beginning cardiopulmonary resuscitation (CPR): 6 min SDA, 6 min HDA, 13 min SDA, or 13 min HDA. After the predetermined duration of untreated ventricular fibrillation, CPR was provided. All animals in the 6 min SDA, 6 min HDA, and 13 min HDA groups were successfully resuscitated, while only 4 of 7 pigs in the 13 min SDA group were successfully resuscitated (p=0.043). HDA groups showed higher right atrial pressure, more frequent ventricular ectopic beats, higher blood glucose, higher troponin-I, and more severe metabolic acidosis than SDA groups. Animals of 13 min groups showed more severe metabolic acidosis and higher troponin-I than animals of 6 min groups. All successfully resuscitated animals, except two animals in the 13 min HDA group, survived for 7 days (p=0.121). Neurologic deficit score was not affected by the dose of adrenaline. HDA showed benefit in achieving restoration of spontaneous circulation in 13 min CA, when compared with 6 min CA. However, this benefit did not translate into improved long-term survival or neurologic outcome. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  3. Sun-Induced Changes in Stratum Corneum Function Are Gender and Dose Dependent in a Chinese Population

    Science.gov (United States)

    Liu, Z.; Fluhr, J.W.; Song, S.P.; Sun, Z.; Wang, H.; Shi, Y.J.; Elias, P.M.; Man, M.-Q.

    2010-01-01

    Previous studies have demonstrated that UVB radiation changes the epidermal permeability barrier and stratum corneum (SC) hydration. It is well known that sun exposure causes erythema, sunburn and melanoma. However, whether daily sun exposure alters SC integrity and epidermal permeability barrier function is largely unknown, especially in Chinese subjects. In the present study, we assess the SC integrity, SC hydration and epidermal permeability barrier function following various doses of sun exposure. A total of 258 subjects (124 males and 134 females) aged 18–50 years were enrolled. A multifunctional skin physiology monitor (Courage & Khazaka MPA5) was used to measure SC hydration and transepidermal water loss (TEWL) on the forearms. In males, basal TEWL was higher with higher doses of sun exposure than with lower doses and control, whereas in females, basal TEWL was higher with lower doses of sun exposure than with higher doses and control. In the group with higher doses of sun exposure, TEWL in females was significantly lower than that in males. The barrier recovery was faster in females than in males in both control and lower-dose groups. In both males and females, barrier recovery was delayed with higher doses of sun exposure. In males, sun exposure did not alter SC hydration, while in females SC hydration was lower with lower doses of sun exposure as compared with control and higher doses of sun exposure. These results demonstrated that sun-induced changes in SC function and SC hydration vary with gender and the extent of sun exposure. PMID:20571289

  4. Sugammadex ED90 dose to reverse the rocuronium neuromuscular blockade in obese patients

    Directory of Open Access Journals (Sweden)

    MAURO PRADO DA SILVA

    Full Text Available ABSTRACT Objective: to determine the ED90 (minimum effective dose in 90% of patients of sugammadex for the reversal of rocuronium-induced moderate neuromuscular blockade (NMB in patients with grade III obesity undergoing bariatric surgery. Methods: we conducted a prospective study with the biased coin up-and-down sequential design. We chosen the following doses: 2.0mg/Kg, 2.2mg/Kg, 2.4mg/Kg, 2.6mg/Kg, 2.8mg/Kg. The complete reversal of rocuronium-induced NMB considered a T4/T1 ratio ≥0.9 as measured by TOF. After induction of general anesthesia and calibration of the peripheral nerve stimulator and accelerometer, we injected rocuronium 0.6mg/kg. We administered propofol and remifentanil by continuous infusion, and intermittent boluses of rocuronium throughout the procedure. Results: we evaluated 31 patients, of whom 26 had displayed successful reversal of the NMB with sugammadex, and failure in five. The mean time to complete moderate NMB reversal was 213 seconds (172-300, median 25-75%. The ED90 of sugammadex calculated by regression was 2.39mg/kg, with a 95% confidence interval of 2.27-2.46 mg/kg. Conclusion: the ED90 of sugammadex in patients with grade III obesity or higher was 2.39mg/kg.

  5. Estimation of pneumonitis risk in three-dimensional treatment planning using dose-volume histogram analysis

    International Nuclear Information System (INIS)

    Oetzel, Dieter; Schraube, Peter; Hensley, Frank; Sroka-Perez, Gabriele; Menke, Markus; Flentje, Michael

    1995-01-01

    Purpose: Investigations to study correlations between the estimations of biophysical models in three dimensional (3D) treatment planning and clinical observations are scarce. The development of clinically symptomatic pneumonitis in the radiotherapy of thoracic malignomas was chosen to test the predictive power of Lyman's normal tissue complication probability (NTCP) model for the assessment of side effects for nonuniform irradiation. Methods and Materials: In a retrospective analysis individual computed-tomography-based 3D dose distributions of a random sample of (46(20)) patients with lung/esophageal cancer were reconstructed. All patients received tumor doses between 50 and 60 Gy in a conventional treatment schedule. Biological isoeffective dose-volume histograms (DVHs) were used for the calculation of complication probabilities after applying Lyman's and Kutcher's DVH-reduction algorithm. Lung dose statistics were performed for single lung (involved ipsilateral and contralateral) and for the lung as a paired organ. Results: In the lung cancer group, about 20% of the patients (9 out of 46) developed pneumonitis 3-12 (median 7.5) weeks after completion of radiotherapy. For the majority of these lung cancer patients, the involved ipsilateral lung received a much higher dose than the contralateral lung, and the pneumonitis patients had on average a higher lung exposure with a doubling of the predicted complication risk (38% vs. 20%). The lower lung exposure for the esophagus patients resulted in a mean lung dose of 13.2 Gy (lung cancer: 20.5 Gy) averaged over all patients in correlation with an almost zero complication risk and only one observed case of pneumonitis (1 out of 20). To compare the pneumonitis risk estimations with observed complication rates, the patients were ranked into bins of mean ipsilateral lung dose. Particularly, in the bins with the highest patient numbers, a good correlation was achieved. Agreement was not reached for the lung functioning as

  6. Dose calculation system for remotely supporting radiotherapy

    International Nuclear Information System (INIS)

    Saito, K.; Kunieda, E.; Narita, Y.; Kimura, H.; Hirai, M.; Deloar, H. M.; Kaneko, K.; Ozaki, M.; Fujisaki, T.; Myojoyama, A.; Saitoh, H.

    2005-01-01

    The dose calculation system IMAGINE is being developed keeping in mind remotely supporting external radiation therapy using photon beams. The system is expected to provide an accurate picture of the dose distribution in a patient body, using a Monte Carlo calculation that employs precise models of the patient body and irradiation head. The dose calculation will be performed utilising super-parallel computing at the dose calculation centre, which is equipped with the ITBL computer, and the calculated results will be transferred through a network. The system is intended to support the quality assurance of current, widely carried out radiotherapy and, further, to promote the prevalence of advanced radiotherapy. Prototypes of the modules constituting the system have already been constructed and used to obtain basic data that are necessary in order to decide on the concrete design of the system. The final system will be completed in 2007. (authors)

  7. Effect of High-Dose vs Standard-Dose Wintertime Vitamin D Supplementation on Viral Upper Respiratory Tract Infections in Young Healthy Children.

    Science.gov (United States)

    Aglipay, Mary; Birken, Catherine S; Parkin, Patricia C; Loeb, Mark B; Thorpe, Kevin; Chen, Yang; Laupacis, Andreas; Mamdani, Muhammad; Macarthur, Colin; Hoch, Jeffrey S; Mazzulli, Tony; Maguire, Jonathon L

    2017-07-18

    Epidemiological studies support a link between low 25-hydroxyvitamin D levels and a higher risk of viral upper respiratory tract infections. However, whether winter supplementation of vitamin D reduces the risk among children is unknown. To determine whether high-dose vs standard-dose vitamin D supplementation reduces the incidence of wintertime upper respiratory tract infections in young children. A randomized clinical trial was conducted during the winter months between September 13, 2011, and June 30, 2015, among children aged 1 through 5 years enrolled in TARGet Kids!, a multisite primary care practice-based research network in Toronto, Ontario, Canada. Three hundred forty-nine participants were randomized to receive 2000 IU/d of vitamin D oral supplementation (high-dose group) vs 354 participants who were randomized to receive 400 IU/d (standard-dose group) for a minimum of 4 months between September and May. The primary outcome was the number of laboratory-confirmed viral upper respiratory tract infections based on parent-collected nasal swabs over the winter months. Secondary outcomes included the number of influenza infections, noninfluenza infections, parent-reported upper respiratory tract illnesses, time to first upper respiratory tract infection, and serum 25-hydroxyvitamin D levels at study termination. Among 703 participants who were randomized (mean age, 2.7 years, 57.7% boys), 699 (99.4%) completed the trial. The mean number of laboratory-confirmed upper respiratory tract infections per child was 1.05 (95% CI, 0.91-1.19) for the high-dose group and 1.03 (95% CI, 0.90-1.16) for the standard-dose group, for a between-group difference of 0.02 (95% CI, -0.17 to 0.21) per child. There was no statistically significant difference in number of laboratory-confirmed infections between groups (incidence rate ratio [RR], 0.97; 95% CI, 0.80-1.16). There was also no significant difference in the median time to the first laboratory-confirmed infection: 3.95 months

  8. Homing regularity of different doses bone marrow transplantation in allogeneic hosts

    International Nuclear Information System (INIS)

    Sun Suping; Cai Jianming; Xiang Yingsong; Zhao Fang; Huang Dingde; Gao Jianguo; Yang Rujun

    2001-01-01

    Objective: To explore the homing regularity of different doses of bone marrow cell transplantation. Method: An allogeneic mouse model was used. The homing status of different dose groups from the first day to the forth day after transplantation were observed. Results: The rate of positive cells in bone marrow and spleen: differences among four groups was not significant. The rate of positive cells of third day was highest among four days (P<0.01). A phenomenon that homing-mobilization-re-homing could be observed. The homing efficiency: low dose groups were higher than that high dose groups (P<0.01). Conclusion: The homing efficiency of low dose groups is higher than that of the high dose groups in certain range, the routine method of transplanting a large quantities cells by a single injection may be an waste

  9. Posttreatment visual acuity in patients treated with episcleral plaque therapy for choroidal melanomas: dose and dose rate effects

    International Nuclear Information System (INIS)

    Jones, Robert; Gore, Elizabeth; Mieler, William; Murray, Kevin; Gillin, Michael; Albano, Katherine; Erickson, Beth

    2002-01-01

    Purpose: To determine the relationship between the long-term visual function and the dose and dose rates delivered to critical ocular structures in patients with choroidal melanoma treated with 125 I episcleral plaque radiotherapy. Methods and Materials: From 1987 to 1994, 63 patients underwent 125 I episcleral plaque (Collaborative Ocular Melanoma Study [COMS] design) application for the treatment of choroidal melanoma. The mean tumor height was 4.5 mm (range 1.7-8.3). Doses and dose rates at the tumor apex, macula, and optic disc were calculated. Forty-three records were scored to assess whether a decrease in visual acuity of >2 lines on a standard Snellen eye chart had occurred. Patient age and the presence of hypertension or diabetes were noted. Statistical analysis was performed to assess both the rate at which visual decline had occurred and the presence of significant factors that had contributed to this decline. Results: With a median follow-up of 36 months, the 3-year actuarial survival rate was 93.6%. The 3-year actuarial local control rate was 86.9%. The median time to visual loss after therapy was 18.7 months. The 3-year actuarial rate of visual preservation was 40.5%. Multivariate analysis demonstrated higher macula dose rates (p=0.003) to forecast visual decline. Macula dose rates of 111±11.1 cGy/h were associated with a 50% risk of significant visual loss. Conclusion: Patients in our series treated with 125 I plaque brachytherapy for choroidal melanoma experienced favorable tumor control, but with a measurable incidence of visual decline. Higher dose rates to the macula correlated strongly with poorer posttreatment visual outcome. This information may be valuable in selecting the optimal dose rates to treat choroidal melanomas and to predict the risk of visual decline

  10. Effect of dose and dose rate of gamma radiation on catalytic activity of catalase

    International Nuclear Information System (INIS)

    Vaclav Cuba; Tereza Pavelkova; Viliam Mucka

    2010-01-01

    Catalytic activity of gamma irradiated catalase from bovine liver was studied for hydrogen peroxide decomposition at constant temperature and pressure. The measurement was performed at temperatures 27, 32, 37, 42 and 47 deg C. Solutions containing 1 and 0.01 g dm -3 of catalase in phosphate buffer were used for the study. Repeatability of both sample preparation and kinetics measurement was experimentally verified. Rate constants of the reaction were determined for all temperatures and the activation energy was evaluated from Arrhenius plot. Gamma irradiation was performed using 60 Co radionuclide source Gammacell 220 at two different dose rates 5.5 and 70 Gy h -1 , with doses ranging from 10 to 1000 Gy. The observed reaction of irradiated and non-irradiated catalase with hydrogen peroxide is of the first order. Irradiation significantly decreases catalytic activity of catalase, but the activation energy does not depend markedly on the dose. The effect of irradiation is more significant at higher dose rate. (author)

  11. Thermal neutron dose calculation in synovium membrane for BNCS

    International Nuclear Information System (INIS)

    Abdalla, Khalid; Naqvi, A.A.; Maalej, N.; El-Shahat, B.

    2006-01-01

    A D(d,n) reaction based setup has been optimized for Boron Neutron Capture Synovectomy (BNCS). The polyethylene moderator and graphite reflector sizes were optimized to deliver the highest ratio of thermal to fast neutron yield. The neutron dose was calculated at various depths in a knee phantom loaded with boron to determine therapeutic ratios of synovium dose/skin dose and synovium dose/bone dose. Normalized to same boron loading in synovium, the values of the therapeutic ratios obtained in the present study are 12-30 times higher than the published values. (author)

  12. Choline PET based dose-painting in prostate cancer - Modelling of dose effects

    International Nuclear Information System (INIS)

    Niyazi, Maximilian; Bartenstein, Peter; Belka, Claus; Ganswindt, Ute

    2010-01-01

    assumption of high detection rates and low initial TCP values the TCP gain has been shown to be relevant. Based on the employed assumptions, specific dose escalation to choline PET positive areas within the prostate may increase the local control rates. Due to the lack of exact PET sensitivity and prostate α/β parameter, no firm conclusions can be made. Small variations may completely abrogate the clinical benefit of a SIB based on choline PET imaging

  13. On-site gamma dose rates at the Andreeva Bay shore technical base, northwest Russia.

    Science.gov (United States)

    Reistad, O; Dowdall, M; Standring, W J F; Selnaes, Ø G; Hustveit, S; Steinhusen, F; Sørlie, A

    2008-07-01

    The spent nuclear fuel (SNF) and radioactive waste (RAW) storage facility at Andreeva Bay shore technical base (STB) is one of the largest and most hazardous nuclear legacy sites in northwest Russia. Originally commissioned in the 1960s the facility now stores large amounts of SNF and RAW associated with the Russian Northern Fleet of nuclear powered submarines. The objective of the present study was to map ambient gamma dose rates throughout the facility, in particular at a number of specific sites where SNF and RAW are stored. The data presented here are taken from a Norwegian-Russian collaboration enabling the first publication in the scientific literature of the complete survey of on-site dose rates. Results indicate that elevated gamma dose rates are found primarily at discrete sites within the facility; maximum dose rates of up to 1000 microSv/h close to the ground (0.1m) and up to 3000 microSv/h at 1m above ground were recorded, higher doses at the 1m height being indicative primarily of the presence of contaminated equipment as opposed to ground contamination. Highest dose rates were measured at sites located in the immediate vicinity of buildings used for storing SNF and sites associated with storage of solid and liquid radioactive wastes. Elevated dose rates were also observed near the former channel of a small brook that became heavily contaminated as a result of radioactive leaks from the SNF storage at Building 5 starting in 1982. Isolated patches of elevated dose rates were also observed throughout the STB. A second paper detailing the radioactive soil contamination at the site is published in this issue of Journal of Environmental Radioactivity.

  14. Radiation tolerance of the spinal cord previously-damaged by tumor operation: long term neurological improvement and time-dose-volume relationships after irradiation of intraspinal gliomas

    International Nuclear Information System (INIS)

    Kopelson, G.

    1982-01-01

    Of 26 patients with intramedullary spinal cord gliomas (9 astrocytomas, 5 glioblastomas, 12 ependymomas) seen at the Massachusetts General Hospital from 1962-1980, 24 were irradiated (21 initially and 3 after post-surgical recurrence). Those 19 patients who survived at least 1 year after completion of irradiation were evaluated for post-irradiation neurological changes.No patient developed radiation myelopathy. Return to a permanently and completely normal neurological status occured for 33/51 (65%) of pre-irradiation neurological deficits. The major cause of post-irradiation neurological deterioration was tumor recurrence. Although 18/19 patients had their thoracic or lumbar spinal cords irradiated, each with field sizes greater than 10 cm, spinal cord doses approaching, equalling, or occasionally exceeding various definitions of spinal cord tolerance were tolerated well without evidence of radiation myelopathy. Spinal cords of patients with intramedullary gliomas, often with major neurological deficits prior to irradiation, may be treated safely to doses approaching or equalling spinal cord tolerance levels. These doses are expected to locally control most ependymomas and astrocytomas without an increased radiation myelopathy. Caution should be observed if doses higher than this are contemplated in an attempt to cure glioblastoma, because the 5% tolerance level of the damaged spinal remains to be defined

  15. Management of patient dose in radiology in the UK

    International Nuclear Information System (INIS)

    Martin, C. J.

    2011-01-01

    Programmes to manage patient dose in radiology are becoming a higher priority as the number of imaging examinations and the proportion of higher dose computed tomography (CT) and complex interventional procedures all continue to rise. Such programmes have a number of components and their implementation in UK hospitals, which have been developing such programmes over two decades, is described. As part of any programme to manage patient doses, elements should be in place for both justification and optimisation. The system for justification needs to be robust in order to minimise the number of unnecessary procedures and requires the provision of training in radiation protection for medical and other staff to ensure that they understand the risks. Optimisation of X-ray techniques requires performance tests on equipment at installation and regularly thereafter, linked to surveys of patient doses. Confirming the performance of the available options on fluoroscopy and CT equipment is essential and the information obtained should be available to radiographers and radiologists, so they can make informed choices in developing imaging protocols. Patient doses should be compared with diagnostic reference levels set in terms of measured dose quantities to allow the identification of equipment that is giving higher doses. Taking the next step of analysing results to determine the reasons for high doses is crucial and requires a link with the equipment performance tests and an understanding of the underlying physics. Medical physics services play an important role at the hub of the dose management programme for carrying out tests, organising surveys, making recommendations on optimisation strategies and training other staff in radiation protection, performance testing and dose reduction. Programmes for management of patient doses in UK hospitals were first set up in the late 1980's by medical physicists and have been developed since that time to keep pace with the developments in

  16. Assessment of dose in thyroid and salivary glands in dental radiology using thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Mantuano, Natalia de O.; Silva, Ademir X. da; Correa, Samanda C.A.

    2011-01-01

    Radiobiological and epidemiological studies have provided evidence of risk of salivary and thyroid glands tumors incidence associated with oral radiology. Based on these studies, the tissue weighting factors were reviewed by the International Commission on Radiological Protection (ICRP) in 2007. The main objective of the present work is to estimate the absorbed dose on thyroid and salivary glands (parotid, submandibular and sublingual), during a complete periapical examination. The complete periapical examination was simulated using a Spectro 70X Seletronic X-ray dental equipment on an Alderson Rando phantom with Harshaw LiF:Mg,Ti thermoluminescent dosemeters (TLD100). A PTW DIADOS dosimetric system was used for calibration. The TLD100 were inserted into the phantom slices corresponding to the organs of interest. During a complete periapical examination, the highest evaluated mean absorbed dose was 4.9 mGy in the right submandibular gland and the lowest one of 1.5 mGy in the left thyroid lobe. Entrance surface doses ranged from 2.1 to 2.6 mGy, measured, respectively, for the techniques of upper left molar and lower right molar. When compared with the diagnostic reference levels (DRL), the entrance surface doses values were lower than the DRLs recommended in Brazilian current legislation. However, the dosimetric results show the need of optimization for complete periapical examination to minimize patient exposure. Measurements were performed without the use of thyroid protectors. The use of this device is certainly an easy and simple method of dose reduction. (author)

  17. Assessment of dose in thyroid and salivary glands in dental radiology using thermoluminescent dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Mantuano, Natalia de O.; Silva, Ademir X. da [Instituto Alberto Luiz Coimbra de Pos-Graduacao e Pesquisa em Engenharia (PEN/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear; Canevaro, Luca V.; Mauricio, Claudia Lucia P. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ) Rio de Janeiro, RJ (Brazil); Correa, Samanda C.A., E-mail: scorrea@cnen.gov.b [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    Radiobiological and epidemiological studies have provided evidence of risk of salivary and thyroid glands tumors incidence associated with oral radiology. Based on these studies, the tissue weighting factors were reviewed by the International Commission on Radiological Protection (ICRP) in 2007. The main objective of the present work is to estimate the absorbed dose on thyroid and salivary glands (parotid, submandibular and sublingual), during a complete periapical examination. The complete periapical examination was simulated using a Spectro 70X Seletronic X-ray dental equipment on an Alderson Rando phantom with Harshaw LiF:Mg,Ti thermoluminescent dosemeters (TLD100). A PTW DIADOS dosimetric system was used for calibration. The TLD100 were inserted into the phantom slices corresponding to the organs of interest. During a complete periapical examination, the highest evaluated mean absorbed dose was 4.9 mGy in the right submandibular gland and the lowest one of 1.5 mGy in the left thyroid lobe. Entrance surface doses ranged from 2.1 to 2.6 mGy, measured, respectively, for the techniques of upper left molar and lower right molar. When compared with the diagnostic reference levels (DRL), the entrance surface doses values were lower than the DRLs recommended in Brazilian current legislation. However, the dosimetric results show the need of optimization for complete periapical examination to minimize patient exposure. Measurements were performed without the use of thyroid protectors. The use of this device is certainly an easy and simple method of dose reduction. (author)

  18. Urochloa ruziziensis responses to sources and doses of urea

    Directory of Open Access Journals (Sweden)

    João E. S. Lima

    2016-05-01

    Full Text Available ABSTRACT The use of products that promote reduction of nitrogen (N losses from the urea fertilizer can contribute to increasing its use efficiency in forage grasses. This study aimed to evaluate the effects of N sources and doses on the growth of Urochloa ruziziensis. The experiment was carried out in the growing season of 2007/2008 in Santo Antônio de Goiás-GO, in a Brazilian Oxisol. A completely randomized block was used, with four replicates in a factorial scheme, corresponding to two N sources (conventional urea and urea with urease inhibitor and five N doses (0, 50, 100, 200 and 300 kg ha-1, divided into equal applications in five periods (Nov 14 to Dec 13, Dec 14 to Jan 12, Jan 13 to Feb 11 - rainy season, Mar 24 to Apr 22 and Jul 10 to Aug 08 - dry season. The effects of the treatments were evaluated for: shoot dry matter, tiller density, total N content in the leaves and relative chlorophyll content. N fertilizer sources did not affect the evaluated variables; however, N fertilization allowed linear increases in all variables with higher values during the rainy period. The relative chlorophyll content in U. ruziziensis had positive correlation with its dry matter productivity.

  19. Dose response relationship for unstable-type chromosome aberration rate of spleen cells from mice continuously exposed to low-dose-rate gamma-rays

    International Nuclear Information System (INIS)

    Tanaka, Kimio; Khoda, Atsushi; Ichinohe, Kazuaki; Oghiso, Yoichi

    2007-01-01

    It has been reported that people who are chronically exposed to radiation such as nuclear facility workers and medical radiologists have slightly higher incidences of chromosome aberrations than non-exposed people. However, chronological changes of chromosome aberration rates related to accumulated doses and dose-rates for low dose-rate radiation exposures have not been well studied. Precise analyses of human populations are quite limited because confounding factors influence the results. For this reason, animal experiments are important for analyses. Mice were continuously exposed to gamma-rays at 400 mGy/22 hr/day for 10 days, 20 mGy/22 hr/day for about 400 days, and 1 mGy/22 hr/day for about 615 days under SPF conditions. Chronological changes of unstable-type chromosome aberration rates of spleen cells were observed along with accumulated doses at the middle dose rate and the two low-dose rates by conventional Giemsa-staining method. Aberrations such as dicentric chromosome, ring chromosome and fragment increased in a two-phase manner within 0-1.2 Gy and 2-8 Gy at 20 mGy/22 hr/day. They slightly increased up to 0.5 Gy at 1 mGy/22 hr/day. Aberration rates for 1, 2, 8 Gy at the 20 mGy/22 hr/day and for 0.5 Gy at 1 mGy/22 hr/day were 5.1, 9.6, 13.9 and 2.2 times higher than those of age-matched, non-irradiated control mice, respectively. Chromosome aberration rates at 400 mGy/22 hr/day were 2.7 times higher than that of 20 mGy/22 hr/day for the same total dose of 1.2 Gy. The results that unstable-type chromosome aberrations increased with accumulated dose of the low-dose rate radiation will be important to establish biological dosimetry for people who are chronically exposed to radiation. (author)

  20. Late biological effects of ionizing radiation as influenced by dose, dose rate, age at exposure, and genetic sensitivity to neoplastic transformation

    International Nuclear Information System (INIS)

    Spalding, J.F.; Prine, J.R.; Tietjen, G.L.

    1978-01-01

    A most comprehensive investigation is in progress at the Los Alamos Scientific Laboratory to study the late biological effects of whole-body exposure to gamma irradiation as they may be influenced by total dose, dose rate, age at exposure, and genetic background. Strain C57B1/6J mice of four age groups (newborn, 2, 6, and 15 months) were given five doses (20, 60, 180, 540, and 1620 rad) of gamma rays, with each dose being delivered at six dose rates (0.7, 2.1, 6.3, 18.9, 56.7 rad/day and 25 rad/min). Forty to sixty mice were used in each of the approximately 110 dose/dose-rate and age combinations. The study was done in two replications with an equal number of mice per replication. Strain RF/J mice were used in a companion study to investigate the influence of genetic background on the type and magnitude of effect. Results of the first and second replications of the 15-month-old age group and data on the influence of genetic background on biological response have been completed, and the results show no significant life shortening within the dose and dose-rate range used

  1. Comparison of a low dose polyethylene glycol electrolyte solution with lactulose for treatment of chronic constipation.

    Science.gov (United States)

    Attar, A; Lémann, M; Ferguson, A; Halphen, M; Boutron, M C; Flourié, B; Alix, E; Salmeron, M; Guillemot, F; Chaussade, S; Ménard, A M; Moreau, J; Naudin, G; Barthet, M

    1999-02-01

    Polyethylene glycol (PEG) 3350 is a non-absorbable, non-metabolised osmotic agent used in lavage solutions for gut cleansing. To compare the efficacy of PEG and lactulose in chronic constipation. A total of 115 patients with chronic constipation entered a multicentre, randomised, comparative trial. They initially received two sachets containing either PEG (13 g/sachet) or lactulose (10 g/sachet) and were given an option to change the dose to one or three sachets/day, depending on response. Ninety nine patients completed the trial. After four weeks, patients in the PEG group (n=50) had a higher number of stools and a lower median daily score for straining at stool than patients in the lactulose group (n=49). Overall improvement was greater in the PEG group. Clinical tolerance was similar in the two groups, but flatus was less frequently reported in the PEG group. The mean number of liquid stools was higher in the PEG group but the difference was significant only for the first two weeks. There were no serious adverse events and no significant change in laboratory tests in either group. At the end of the study, the number of sachets used by the patients was 1.6 (0.7)/day in the PEG group and 2.1 (0.7)/day in the lactulose group. Sixty one patients completed a further two months open study of one to three sachets PEG daily; there was no loss of efficacy and no serious toxicity. Low dose PEG 3350 was more effective than lactulose and better tolerated.

  2. Radiation therapy in the management of symptomatic bone metastases: the effect of total dose and histology on pain relief and response duration

    International Nuclear Information System (INIS)

    Arcangeli, Giorgio; Giovinazzo, Giuseppe; Saracino, Biancamaria; D'Angelo, Luciano; Giannarelli, Diana; Arcangeli, Giancarlo; Micheli, Adriana

    1998-01-01

    the several ranges of total dose delivered to the painful metastases, with 81%, 65%, and 46% complete relief rates in the 40-46 Gy, 30-36 Gy (p 0.03), and 8-28 Gy (p = 0.0001) dose ranges respectively. A straight correlation between total dose and complete pain relief was confirmed by the curve calculated by the logistic model which shows that doses of 30 Gy or more are necessary to achieve complete pain relief in 70% or more of bone metastases. This correlation holds also for the duration of pain control, as shown by the actuarial analysis of time to pain progression. Multivariate analyses, with complete pain relief and time to pain progression as endpoints show a highly significant effect of radiation dose (p = 0.0007) and performance status (p = 0.003), with lower rates of complete pain relief and shorter time to pain progression observed after smaller radiation total doses or higher Eastern Cooperative Oncology Group (ECOG) scores. Conclusion: Although single-dose or short course irradiation is an attractive treatment in reducing the number of multiple visits to radiotherapy departments for patients with painful bone metastases, it is nevertheless clear that aggressive protracted treatments seem to offer significant advantages especially for patients in whom the expected life span is not short

  3. Estimate of ovarian dose and entrance skin dose in uterine artery embolization procedures

    International Nuclear Information System (INIS)

    Silva, Marcia C.; Nasser, Felipe; Affonso, Breno B.; Araujo Junior, Raimundo T.; Zlotnik, Eduardo; Messina, Marcos L.; Baracat, Edmund C.

    2010-01-01

    The goal of this study was to estimate the ovarian dose and entrance skin dose (ESD) of patients who underwent uterine artery embolization (UAE) procedure. To achieve this, 49 UAE procedures were accompanied where the parameters of image acquisition were recorded for the calculation of the DEP from the output of the X-ray tube. The estimation of the ovarian dose was carried out by the insertion of a vaginal probe containing 3 TLD's. The obtained values were compared with the results of other authors and a higher value of ovarian dose (28,97 cGy) and ESD (403,57 cGy) was found in this work. Analysis of the results allowed to observe that this result was obtained mainly as a result of the high number of arteriography series and the frames/second rates employed. Following on from these observations, the protocol of EMUT was altered reducing the frames/seg rate from 2 to 1. Efforts with a view to reducing the number of arteriography series also became part of the next proceedings. (author)

  4. Surface dose measurements and comparison of unflattened and flattened photon beams

    Directory of Open Access Journals (Sweden)

    Ashokkumar Sigamani

    2016-01-01

    Full Text Available The purpose of this study was to evaluate the central axis dose in the build-up region and the surface dose of a 6 MV and 10 MV flattened photon beam (FB and flattening filter free (FFF therapeutic photon beam for different square field sizes (FSs for a Varian Truebeam linear accelerator using parallel-plate ionization chamber and Gafchromic film. Knowledge of dosimetric characteristics in the build-up region and surface dose of the FFF is essential for clinical care. The dose measurements were also obtained empirically using two different commonly used dosimeters: a p-type photon semiconductor dosimeter and a cylindrical ionization chamber. Surface dose increased linearly with FS for both FB and FFF photon beams. The surface dose values of FFF were higher than the FB FSs. The measured surface dose clearly increases with increasing FS. The FFF beams have a modestly higher surface dose in the build-up region than the FB. The dependence of source to skin distance (SSD is less significant in FFF beams when compared to the flattened beams at extended SSDs.

  5. Low-dose strontium stimulates osteogenesis but high-dose doses cause apoptosis in human adipose-derived stem cells via regulation of the ERK1/2 signaling pathway.

    Science.gov (United States)

    Aimaiti, Abudousaimi; Maimaitiyiming, Asihaerjiang; Boyong, Xu; Aji, Kaisaier; Li, Cao; Cui, Lei

    2017-12-19

    Strontium is a widely used anti-osteoporotic agent due to its dual effects on inhibiting bone resorption and stimulating bone formation. Thus, we studied the dose response of strontium on osteo-inductive efficiency in human adipose-derived stem cells (hASCs). Qualitative alkaline phosphatase (ALP) staining, quantitative ALP activity, Alizarin Red staining, real-time polymerase chain reaction and Western blot were used to investigate the in vitro effects of a range of strontium concentrations on hASC osteogenesis and associated signaling pathways. In vitro work revealed that strontium (25-500 μM) promoted osteogenic differentiation of hASCs according to ALP activity, extracellular calcium deposition, and expression of osteogenic genes such as runt-related transcription factor 2, ALP, collagen-1, and osteocalcin. However, osteogenic differentiation of hASCs was significantly inhibited with higher doses of strontium (1000-3000 μM). These latter doses of strontium promoted apoptosis, and phosphorylation of ERK1/2 signaling was increased and accompanied by the downregulation of Bcl-2 and increased phosphorylation of BAX. The inhibition of ERK1/2 decreased apoptosis in hASCs. Lower concentrations of strontium facilitate osteogenic differentiation of hASCs up to a point; higher doses cause apoptosis of hASCs, with activation of the ERK1/2 signaling pathway contributing to this process.

  6. Assessment of radioactive residues arising from radiolabel instability in a multiple dose tissue distribution study in rats

    International Nuclear Information System (INIS)

    Slatter, J.G.; Sams, J.P.; Easter, J.A.

    2003-01-01

    Our study objectives were to quantitatively determine the effect of radiolabel instability on terminal phase radioactive tissue residues in a multiple dose tissue distribution study, to quantitatively compare tissue residue artifacts (non drug-related radioactivity) from two chemically-distinct radiolabel locations, and to conduct a definitive multiple dose tissue distribution study using the better of the two radiolabeled compounds. We compared the excretion and tissue distribution in rats of [ 14 C]linezolid, radiolabeled in two different locations, after 7 consecutive once daily [ 14 C] oral doses. The radiolabels were in the acetamide (two carbon) and oxazolidinone (isolated carbon) functional groups. Terminal phase tissue residue and excretion data were compared to data from rats dosed orally with [ 14 C]sodium acetate. Drug-related radioactivity was excreted rapidly over 24 h. After a single dose, the acetamide and oxazolidinone radiolabel sites both gave 3% of dose as exhaled 14 CO 2 . After 7 daily [ 14 C] oral doses, terminal phase radioactive tissue residues were higher from the acetamide radiolabel, relative to the oxazolidinone radiolabel, and were primarily not drug-related. In the definitive tissue distribution study, low concentrations of drug-related radioactivity in skin and thyroid were observed. We conclude that although small amounts of radiolabel instability do not significantly affect single dose tissue radioactivity C max and area under the curve (AUC), artifacts arising from radiolabel instability can prolong the apparent terminal phase half life and complicate study data interpretation. When possible, it is always preferable to use a completely stable radiolabel site. (author)

  7. Assessment of radioactive residues arising from radiolabel instability in a multiple dose tissue distribution study in rats

    Energy Technology Data Exchange (ETDEWEB)

    Slatter, J.G. [Pharmacia Corp., Peapack, NJ (United States); Sams, J.P.; Easter, J.A. [Pharmacia Corp., Kalamazoo, MI (United States)] [and others

    2003-05-01

    Our study objectives were to quantitatively determine the effect of radiolabel instability on terminal phase radioactive tissue residues in a multiple dose tissue distribution study, to quantitatively compare tissue residue artifacts (non drug-related radioactivity) from two chemically-distinct radiolabel locations, and to conduct a definitive multiple dose tissue distribution study using the better of the two radiolabeled compounds. We compared the excretion and tissue distribution in rats of [{sup 14}C]linezolid, radiolabeled in two different locations, after 7 consecutive once daily [{sup 14}C] oral doses. The radiolabels were in the acetamide (two carbon) and oxazolidinone (isolated carbon) functional groups. Terminal phase tissue residue and excretion data were compared to data from rats dosed orally with [{sup 14}C]sodium acetate. Drug-related radioactivity was excreted rapidly over 24 h. After a single dose, the acetamide and oxazolidinone radiolabel sites both gave 3% of dose as exhaled {sup 14}CO{sub 2}. After 7 daily [{sup 14}C] oral doses, terminal phase radioactive tissue residues were higher from the acetamide radiolabel, relative to the oxazolidinone radiolabel, and were primarily not drug-related. In the definitive tissue distribution study, low concentrations of drug-related radioactivity in skin and thyroid were observed. We conclude that although small amounts of radiolabel instability do not significantly affect single dose tissue radioactivity C{sub max} and area under the curve (AUC), artifacts arising from radiolabel instability can prolong the apparent terminal phase half life and complicate study data interpretation. When possible, it is always preferable to use a completely stable radiolabel site. (author)

  8. Radiation doses in endoscopic interventional procedures

    International Nuclear Information System (INIS)

    Tsapaki, V.; Paraskeva, K.; Mathou, N.; Aggelogiannopoulou, P.; Triantopoulou, C.; Karagianis, J.; Giannakopoulos, A.; Paspatis, G.; Voudoukis, E.; Athanasopoulos, N.; Lydakis, I.; Scotiniotis, H.; Georgopoulos, P.; Finou, P.; Kadiloru, E.

    2012-01-01

    Purpose: Extensive literature exists on patient radiation doses in various interventional procedures. This does not stand for endoscopic retrograde cholangiopancreatography (ERCP) where the literature is very limited. This study compares patient dose during ERCP procedures performed with different types of X-ray systems. Methods and Materials: Four hospitals participated in the study with the following X-ray systems: A) X-ray conventional system (X-ray tube over table), 137 pts, B) X-ray conventional system (X-ray tube under table), 114 pts, C) C-arm system, 79 pts, and D) angiography system, 57 pts. A single experienced endoscopist performed the ERCP in each hospital. Kerma Area Product (KAP), fluoroscopy time (T) and total number of X-ray films (F) were collected. Results: Median patient dose was 6.2 Gy.cm 2 (0.02-130.2 Gy.cm 2 ). Medium linear correlation between KAP and T (0.6) and F (0.4) were observed. Patient doses were 33 % higher than the reference value in UK (4.15 Gy.cm 2 with a sample of 6089 patients). Median KAP for each hospital was: A) 3.1, B) 9.2, C) 3.9 and D) 6.2 Gy.cm 2 . Median T was: A) 2.6, B) 4.1, C) 2.8 and D) 3.4 min. Median F was: A) 2, B) 7, C) 2 and D) 2 films. Conclusion: Patient radiation dose during ERCP depends on: a) fluoroscopy time and films taken, b) the type of the X-ray system used, with the C arm and the conventional over the couch systems carrying the lower patient radiation dose and the angiography system the higher. (authors)

  9. Determination of crossed gamma doses for garlic improvement (Allium Sativum)

    International Nuclear Information System (INIS)

    Perez Talavera, S.; Labrada, A.; Savin, V.

    1991-01-01

    The determination of four Cuban varieties of garlic was made so as to optimized the use of ionizing radiations in Cuba to breed vegetatively propagated crops such as garlic. The dose-effect regresion equation characterizing the radioinhibition zone of each crop was presented. We used a criteria to select the irradiation dose to be used in mutation breeding techniques based on obtaining height variability in the productive indicators, a survival and a number of garlic cloves high enough to allow and adequate reproduction of M1 plants. It was verified that this small inhibitor doses of radiations produced a higher percentage of good variability than the medium and high doses. With the use of small inhibitor doses (GR10-GR20) on the Guadalupe-15 garlic variety, 65 variety plants were obtained., 93.7% out of this number is higher than the control in the indicators considered

  10. Dose assessment in pediatric computerized tomography; Avaliacao de doses em tomografia computadorizada pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Vilarinho, Luisa Maria Auredine Lima

    2004-07-01

    The objective of this work was the evaluation of radiation doses in paediatric computed tomography scans, considering the high doses usually involved and the absence of any previous evaluation in Brazil. Dose values were determined for skull and abdomen examinations, for different age ranges, by using the radiographic techniques routinely used in the clinical centers investigated. Measurements were done using pencil shape ionization chambers inserted in polymethylmethacrylate (PMMA) phantoms. These were compact phantoms of different diameters were specially designed and constructed for this work, which simulate different age ranges. Comparison of results with published values showed that doses were lower than the diagnostic reference levels established to adults exams by the European Commission. Nevertheless, doses in paediatric phantoms were higher than those obtained in adult phantoms. The paediatric dose values obtained in Hospitals A and B were lower than the reference level (DRL) adopted by SHIMPTON for different age ranges. In the range 0 - 0.5 year (neonatal), the values of DLP in Hospital B were 94 por cent superior to the DRL For the 10 years old children the values of CTDI{sub w} obtained were inferior in 89 por cent for skull and 83 por cent for abdomen examinations, compared to the values published by SHRIMPTON and WALL. Our measured CTDI{sub w} values were inferior to the values presented for SHRIMPTON and HUDA, for all the age ranges and types of examinations. It was observed that the normalized dose descriptors values in children in the neonatal range were always superior to the values of doses for the adult patient. In abdomen examinations, the difference was approximately 90% for the effective dose (E) and of 57%.for CTDI{sub w} . (author)

  11. Oral sodium phenylbutyrate in patients with recurrent malignant gliomas: A dose escalation and pharmacologic study1

    Science.gov (United States)

    Phuphanich, Surasak; Baker, Sharyn D.; Grossman, Stuart A.; Carson, Kathryn A.; Gilbert, Mark R.; Fisher, Joy D.; Carducci, Michael A.

    2005-01-01

    We determined the maximum tolerated dose (MTD), toxicity profile, pharmacokinetic parameters, and preliminary efficacy data of oral sodium phenylbutyrate (PB) in patients with recurrent malignant gliomas. Twenty-three patients with supratentorial recurrent malignant gliomas were enrolled on this dose escalation trial. Four dose levels of PB were studied: 9, 18, 27, and 36 g/day. Data were collected to assess toxicity, response, survival, and pharmacokinetics. All PB doses of 9, 18, and 27 g/day were well tolerated. At 36 g/day, two of four patients developed dose-limiting grade 3 fatigue and somnolence. At the MTD of 27 g/day, one of seven patients developed reversible grade 3 somnolence. Median survival from time of study entry was 5.4 months. One patient had a complete response for five years, and no partial responses were noted, which yielded an overall response rate of 5%. Plasma concentrations of 706, 818, 1225, and 1605 μM were achieved with doses of 9, 18, 27, and 36 g/day, respectively. The mean value for PB clearance in this patient population was 22 liters/h, which is significantly higher than the 16 liters/h reported in patients with other malignancies who were not receiving P450 enzyme–inducing anticonvulsant drugs (P = 0.038). This study defines the MTD and recommended phase 2 dose of PB at 27 g/day for heavily pretreated patients with recurrent gliomas. The pharmacology of PB appears to be affected by concomitant administration of P450-inducing anticonvulsants. PMID:15831235

  12. Matrix completion by deep matrix factorization.

    Science.gov (United States)

    Fan, Jicong; Cheng, Jieyu

    2018-02-01

    Conventional methods of matrix completion are linear methods that are not effective in handling data of nonlinear structures. Recently a few researchers attempted to incorporate nonlinear techniques into matrix completion but there still exists considerable limitations. In this paper, a novel method called deep matrix factorization (DMF) is proposed for nonlinear matrix completion. Different from conventional matrix completion methods that are based on linear latent variable models, DMF is on the basis of a nonlinear latent variable model. DMF is formulated as a deep-structure neural network, in which the inputs are the low-dimensional unknown latent variables and the outputs are the partially observed variables. In DMF, the inputs and the parameters of the multilayer neural network are simultaneously optimized to minimize the reconstruction errors for the observed entries. Then the missing entries can be readily recovered by propagating the latent variables to the output layer. DMF is compared with state-of-the-art methods of linear and nonlinear matrix completion in the tasks of toy matrix completion, image inpainting and collaborative filtering. The experimental results verify that DMF is able to provide higher matrix completion accuracy than existing methods do and DMF is applicable to large matrices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Higher English for CFE

    CERN Document Server

    Bridges, Ann; Mitchell, John

    2015-01-01

    A brand new edition of the former Higher English: Close Reading , completely revised and updated for the new Higher element (Reading for Understanding, Analysis and Evaluation) - worth 30% of marks in the final exam!. We are working with SQA to secure endorsement for this title. Written by two highly experienced authors this book shows you how to practice for the Reading for Understanding, Analysis and Evaluation section of the new Higher English exam. This book introduces the terms and concepts that lie behind success and offers guidance on the interpretation of questions and targeting answer

  14. A phase I study of dose-escalated chemoradiation with accelerated intensity modulated radiotherapy in locally advanced head and neck cancer

    International Nuclear Information System (INIS)

    Guerrero Urbano, Teresa; Clark, Catharine H.; Hansen, Vibeke N.; Adams, Elizabeth J.; A'Hern, Roger; Miles, Elizabeth A.; McNair, Helen; Bidmead, Margaret; Warrington, Alan P.; Dearnaley, David P.; Harrington, Kevin J.; Nutting, Christopher M.

    2007-01-01

    Background and purpose: Intensity modulated radiotherapy (IMRT) allows the delivery of higher and more homogeneous radiation dose to head and neck tumours. This study aims to determine the safety of dose-escalated chemo-IMRT for larynx preservation in locally advanced head and neck cancer. Methods: Patients with T2-4, N1-3, M0 squamous cell carcinoma of the larynx or hypopharynx were treated with a simultaneous-boost IMRT. Two radiation dose levels (DL) were tested: In DL 1, 63 Gy/28F was delivered to primary tumour and involved nodes and 51.8 Gy/28F to elective nodes. In DL 2, the doses were 67.2 Gy/28F and 56 Gy/28F, respectively, representing a 9% dose escalation for the primary. All patients received 2 cycles of neoadjuvant cisplatin and 5-fluorouracil, and concomitant cisplatin. Acute (NCICTCv.2.0) and late toxicity (RTOG and modified LENTSOM) were collected. Results: Thirty patients were entered, 15 in each dose level. All patients completed the treatment schedule. In DL 1, the incidences of acute G3 toxicities were 27% (pain), 20% (radiation dermatitis), 0% (xerostomia) and 67% required gastrostomy tubes. For DL 2 the corresponding incidences were 40%, 20%, 7%, and 87%. G3 dysphagia and pain persisted longer in DL 2. With regard to mucositis, a prolonged healing time for DL 2 was found, with prevalence of G2 of 58% in week 10. No acute grade 4 toxicity was observed. At 6 months, 1 patient in DL 2 had G3 late toxicity (dysphagia). No dose limiting toxicity was found. Complete response rates were 80% in DL 1, and 87% in DL 2. Conclusion: Moderately accelerated chemo-IMRT is safe and feasible with good compliance and acceptable acute toxicity. Dose escalation was possible without a significant difference in acute toxicity. Longer follow-up is required to determine the incidence of late radiation toxicities, and tumour control rates

  15. Determination of effective dose of antimalarial from Cassia ...

    African Journals Online (AJOL)

    However, further investigation is required to determine an effective dose of the administered extract for a higher inhibitory effect and increasing effectiveness of the extract. Material and Methods: To determine the effective dose of ethanol extract of C. spectabilis leaves, a "4-day suppressive test"of Peter was performed with ...

  16. Response of human and rabbit lymphocytes to low doses of X-rays

    International Nuclear Information System (INIS)

    Fabry, L.

    1982-01-01

    The response of human and rabbit lymphocytes to low doses of X-rays was studied by the yields of dicentrics in first division metaphases. For both species, the dose-response curve was best fitted to the linear-quadratic model with a linear component predominating up to 67 and 42 rad respectively for man and rabbit. A calibration curve (5-400 rad) was obtained by combining the present results on man with previous data at higher doses. On the other hand, it appears that, at low doses, the radiosentivity of human lymphocytes is significantly higher than that of rabbit lymphocytes [fr

  17. Estimation of dose from chromosome aberration rate

    International Nuclear Information System (INIS)

    Li Deping

    1990-01-01

    The methods and skills of evaluating dose from correctly scored shromsome aberration rate are presented, and supplemented with corresponding BASIC computer code. The possibility and preventive measures of excessive probability of missing score of the aberrations in some of the current routine score methods are discussed. The use of dose-effect relationship with exposure time correction factor G in evaluating doses and their confidence intervals, dose estimation in mixed n-γ exposure, and identification of high by nonuniform acute exposure to low LET radiation and its dose estimation are discussed in more detail. The difference of estimated dose due to whether the interaction between subleisoms produced by n and γ have been taken into account is examined. In fitting the standard dose-aberration rate curve, proper weighing of experiment points and comparison with commonly accepted values are emphasised, and the coefficient of variation σ y √y of the aberration rate y as a function of dose and exposure time is given. In appendix I and II, the dose-aberration rate formula is derived from dual action theory, and the time variation of subleisom is illustrated and in appendix III, the estimation of dose from scores of two different types of aberrations (of other related score) is illustrated. Two computer codes are given in appendix IV, one is a simple code, the other a complete code, including the fitting of standard curve. the skills of using compressed data storage, and the production of simulated 'data ' for testing the curve fitting procedure are also given

  18. Patient doses in digital cardiac imaging

    International Nuclear Information System (INIS)

    Huda, W.; Ogden, K.M.; Roskopf, M.L.; Phadke, K.

    2001-01-01

    In this pilot study, we obtained estimates of entrance skin doses and the corresponding effective doses to patients undergoing digital cardiac imaging procedures on a GE Advantx LC/LP Plus system. Data were obtained for six patients undergoing diagnostic examinations and six patients who had interventional procedures. For each patient examination, radiographic techniques for fluoroscopic and digital cine imaging were recorded, together with the irradiation geometry. The projection with the highest exposure resulted in an average skin dose of 0.64 ± 0.41 Gy (maximum of 1.6 Gy). The average patient skin doses taking into account overlapping projections was 1.1 ± 0.8 Gy (maximum of 3.0 Gy). The exposure area product (EAP) incident on the patient was converted into the energy imparted to the patient and the corresponding effective dose. The average patient effective dose was 28 ± 14 mSv (maximum 62 mSv), with the resultant average fatal cancer risk estimated to be of the order of 8x10 -3 . Average doses for interventional procedures in cardiac imaging are higher than those associated with diagnostic examinations by approximately 50%. (author)

  19. Assessment of inhalation dose sensitivity by physicochemical properties of airborne particulates containing naturally occurring radioactive materials

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Si Young; Choi, Cheol Kyu; Kim, Yong Geon; Choi, Won Chul; Kim, Kwang Pyo [Kyung Hee University, Seoul (Korea, Republic of)

    2015-12-15

    Facilities processing raw materials containing naturally occurring radioactive materials (NORM) may give rise to enhanced radiation dose to workers due to chronic inhalation of airborne particulates. Internal radiation dose due to particulate inhalation varies depending on particulate properties, including size, shape, density, and absorption type. The objective of the present study was to assess inhalation dose sensitivity to physicochemical properties of airborne particulates. Committed effective doses to workers resulting from inhalation of airborne particulates were calculated based on International Commission on Radiological Protection 66 human respiratory tract model. Inhalation dose generally increased with decreasing particulate size. Committed effective doses due to inhalation of 0.01μm sized particulates were higher than doses due to 100μm sized particulates by factors of about 100 and 50 for {sup 238}U and {sup 230}Th, respectively. Inhalation dose increased with decreasing shape factor. Shape factors of 1 and 2 resulted in dose difference by about 18 %. Inhalation dose increased with particulate mass density. Particulate mass densities of 11 g·cm{sup -3} and 0.7 g·cm{sup -3} resulted in dose difference by about 60 %. For {sup 238}U, inhalation doses were higher for absorption type of S, M, and F in that sequence. Committed effective dose for absorption type S of {sup 238}U was about 9 times higher than dose for absorption F. For {sup 230}Th, inhalation doses were higher for absorption type of F, M, and S in that sequence. Committed effective dose for absorption type F of {sup 230}Th was about 16 times higher than dose for absorption S. Consequently, use of default values for particulate properties without consideration of site specific physiochemical properties may potentially skew radiation dose estimates to unrealistic values up to 1-2 orders of magnitude. For this reason, it is highly recommended to consider site specific working materials and

  20. LDR brachytherapy: can low dose rate hypersensitivity from the "inverse" dose rate effect cause excessive cell killing to peripherial connective tissues and organs?

    Science.gov (United States)

    Leonard, B E; Lucas, A C

    2009-02-01

    Examined here are the possible effects of the "inverse" dose rate effect (IDRE) on low dose rate (LDR) brachytherapy. The hyper-radiosensitivity and induced radioresistance (HRS/IRR) effect benefits cell killing in radiotherapy, and IDRE and HRS/IRR seem to be generated from the same radioprotective mechanisms. We have computed the IDRE excess cell killing experienced in LDR brachytherapy using permanent seed implants. We conclude, firstly, that IDRE is a dose rate-dependent manifestation of HRS/IRR. Secondly, the presence of HRS/IRR or IDRE in a cell species or tissue must be determined by direct dose-response measurements. Thirdly, a reasonable estimate is that 50-80% of human adjoining connective and organ tissues experience IDRE from permanent implanted LDR brachytherapy. If IDRE occurs for tissues at point A for cervical cancer, the excess cell killing will be about a factor of 3.5-4.0 if the initial dose rate is 50-70 cGy h(-1). It is greater for adjacent tissues at lower dose rates and higher for lower initial dose rates at point A. Finally, higher post-treatment complications are observed in LDR brachytherapy, often for unknown reasons. Some of these are probably a result of IDRE excess cell killing. Measurements of IDRE need be performed for connective and adjacent organ tissues, i.e. bladder, rectum, urinary tract and small bowels. The measured dose rate-dependent dose responses should extended to tissues and organs remain above IDRE thresholds).

  1. Predictors of Participation and Completion in a Workplace Education Program.

    Science.gov (United States)

    Smith, Paula Sue; White, Bonnie Roe

    1997-01-01

    Responses from 351 employee participants in a workplace education program (218 completers) indicated they were mostly white, female high school graduates ages 26 to 35. Women with Test of Adult Basic Education math scores below 5.0 were less likely to complete. Those who completed higher grades in school were more likely to participate. (SK)

  2. Transatlantic Comparison of CT Radiation Doses in the Era of Radiation Dose-Tracking Software.

    Science.gov (United States)

    Parakh, Anushri; Euler, Andre; Szucs-Farkas, Zsolt; Schindera, Sebastian T

    2017-12-01

    The purpose of this study is to compare diagnostic reference levels from a local European CT dose registry, using radiation-tracking software from a large patient sample, with preexisting European and North American diagnostic reference levels. Data (n = 43,761 CT scans obtained over the course of 2 years) for the European local CT dose registry were obtained from eight CT scanners at six institutions. Means, medians, and interquartile ranges of volumetric CT dose index (CTDI vol ), dose-length product (DLP), size-specific dose estimate, and effective dose values for CT examinations of the head, paranasal sinuses, thorax, pulmonary angiogram, abdomen-pelvis, renal-colic, thorax-abdomen-pelvis, and thoracoabdominal angiogram were obtained using radiation-tracking software. Metrics from this registry were compared with diagnostic reference levels from Canada and California (published in 2015), the American College of Radiology (ACR) dose index registry (2015), and national diagnostic reference levels from local CT dose registries in Switzerland (2010), the United Kingdom (2011), and Portugal (2015). Our local registry had a lower 75th percentile CTDI vol for all protocols than did the individual internationally sourced data. Compared with our study, the ACR dose index registry had higher 75th percentile CTDI vol values by 55% for head, 240% for thorax, 28% for abdomen-pelvis, 42% for thorax-abdomen-pelvis, 128% for pulmonary angiogram, 138% for renal-colic, and 58% for paranasal sinus studies. Our local registry had lower diagnostic reference level values than did existing European and North American diagnostic reference levels. Automated radiation-tracking software could be used to establish and update existing diagnostic reference levels because they are capable of analyzing large datasets meaningfully.

  3. Transferases activity in blood plasma of chickens hatched from eggs irradiated during incubation by low dose gamma rays

    International Nuclear Information System (INIS)

    Kraljevic, P.; Vilic, M.; Miljanic, S.; Simpraga, M.

    2005-01-01

    In our earlier studies chickens hatched from eggs irradiated with 0.15 Gy gamma rays before incubation showed a significantly higher growth than controls during the fattening period (1-42 days). The activity of aspartate-aminotransferase (AST), alanine-aminotransferase (ALT) and plasma glucose in the same chickens were also significantly higher. These results suggested that low-dose gamma-radiation stimulated certain metabolic processes in chickens hatched from eggs irradiated before incubation. The goal of this study was to determine the effects of low-dose ionising radiation on AST and ALT activity in the blood plasma of chickens hatched from eggs irradiated during incubation. The eggs of heavy breeding chickens (Avian, line 34) were exposed to 0.15 Gy of gamma-radiation (6 0C o) on the seventh day of incubation, i.e. at the time when the organogenesis in chickens is completed. The control group of chickens hatched from non-irradiated eggs. All other conditions were the same for both groups. After hatching, blood samples were taken from the wing vein on days 1, 3, 5, 7, 10, 20, 32 and 42. The activity of both enzymes was determined spectrophotometrically using Boehringer Mannheim GmbH optimised kits. On day 10, AST and ALT activity were significantly higher in the blood plasma of chickens hatched from irradiated eggs, but it significantly dropped for both enzymes on day 20. Our results indicate that exposure of eggs to low-dose gamma-radiation on the seventh day of incubation affects AST and ALT activity in the blood plasma of chickens hatched from irradiated eggs. However, this effect is somewhat different from the effects of egg exposure to low-dose gamma radiation before incubation.(author)

  4. The crooked shall be made straight: dose response relationships for carcinogenesis

    International Nuclear Information System (INIS)

    Hall, E.J.

    2003-01-01

    Estimates of radiation-induced malignancies come principally from the A-bomb survivors and from medically exposed individuals, including second cancers in radiotherapy patients. The A-bomb survivors show an excess incidence of carcinomas which is linear with dose from about 10 cGy to 2.5 Gy. Above and below this dose range, there is considerable uncertainty concerning the shape of the dose response relationship. These two dose ranges will be discussed separately. Low dose extrapolations ICRP and NCRP suggest that cancer risks at doses lower than those at which direct epidemiological observations are possible should be obtained by a linear extrapolation from higher doses. This is labeled a 'prudent and conservative' assumption but is a subject of considerable controversy. Two factors, the existence of radiosensitive subgroups in the human population (such as AT heterozygotes), and the demonstration of a Bystander effect both exaggerate the consequences of small doses of radiation and imply that a linear extrapolation from high doses would underestimate low dose risks. High dose extrapolations In the context of radiotherapy, some normal tissues receive 70 Gy, while a larger volume receives a lower dose, but still far higher than the range for which data are available from the A-bomb survivors. The question is, what is the dose response for carcinogenesis in the range 10 to 70 Gy? At one extreme, it might be expected that the risk of inducing cancer would fall off rapidly at higher does due to cell killing. The other extreme possibility is that the risk of solid tumors levels off by about 10 Gy, but does not decline thereafter. For a few cancers, data are available from 2 Gy in A-bomb survivors to 70 Gy in radiotherapy patients, and it appears that the relative risk does not vary with dose. This implies that the volume of tissue irradiated is more important than the maximum dose. This result has far reaching implications for new technologies such as IMRT, which

  5. Occupational radiation doses during interventional procedures

    International Nuclear Information System (INIS)

    Nuraeni, N; Hiswara, E; Kartikasari, D; Waris, A; Haryanto, F

    2016-01-01

    Digital subtraction angiography (DSA) is a type of fluoroscopy technique used in interventional radiology to clearly visualize blood vessels in a bony or dense soft tissue environment. The use of DSA procedures has been increased quite significantly in the Radiology departments in various cities in Indonesia. Various reports showed that both patients and medical staff received a noticeable radiation dose during the course of this procedure. A study had been carried out to measure these doses among interventionalist, nurse and radiographer. The results show that the interventionalist and the nurse, who stood quite close to the X-ray beams compared with the radiographer, received radiation higher than the others. The results also showed that the radiation dose received by medical staff were var depending upon the duration and their position against the X-ray beams. Compared tothe dose limits, however, the radiation dose received by all these three medical staff were still lower than the limits. (paper)

  6. High-dose metoclopramide + lorazepam versus low-dose metoclopramide + lorazepam + dehydrobenzperidol in the treatment of cisplatin-induced nausea and vomiting

    DEFF Research Database (Denmark)

    Herrstedt, Jørn; Hannibal, J; Hallas, Jesper

    1991-01-01

    In a randomized double-blind, cross-over trial of 34 patients receiving cisplatin-based chemotherapy (20-100 mg/m2), the antiemetic effect of high-dose metoclopramide (HDM) (10 mg/kg iv. loading dose + 7 hours continuous infusion) + lorazepam (L) (2.5 mg x 4 po) was compared with low......-dose metoclopramide (LDM) (70 mg) + L (2.5 mg x 2 po) + dehydrobenzperidol (5 mg x 2 im). Among the 29 patients who completed the cross-over, HDM significantly reduced the number of vomiting episodes (p = 0.002) and the degree of nausea (p = 0.004). Seventeen patients preferred the HDM and 4 the LDM regimen (p = 0.......01). Sedation was seen in all but 1 patient, and was graded as severe in 6 patients receiving the HDM and in 2 patients receiving the LDM regimen. No extrapyramidal adverse reactions were seen. We conclude that high-dose metoclopramide + lorazepam is a safe antiemetic regimen and significantly superior to low...

  7. Dose specification for radiation therapy: dose to water or dose to medium?

    International Nuclear Information System (INIS)

    Ma, C-M; Li Jinsheng

    2011-01-01

    The Monte Carlo method enables accurate dose calculation for radiation therapy treatment planning and has been implemented in some commercial treatment planning systems. Unlike conventional dose calculation algorithms that provide patient dose information in terms of dose to water with variable electron density, the Monte Carlo method calculates the energy deposition in different media and expresses dose to a medium. This paper discusses the differences in dose calculated using water with different electron densities and that calculated for different biological media and the clinical issues on dose specification including dose prescription and plan evaluation using dose to water and dose to medium. We will demonstrate that conventional photon dose calculation algorithms compute doses similar to those simulated by Monte Carlo using water with different electron densities, which are close (<4% differences) to doses to media but significantly different (up to 11%) from doses to water converted from doses to media following American Association of Physicists in Medicine (AAPM) Task Group 105 recommendations. Our results suggest that for consistency with previous radiation therapy experience Monte Carlo photon algorithms report dose to medium for radiotherapy dose prescription, treatment plan evaluation and treatment outcome analysis.

  8. Cranial CT with adaptive statistical iterative reconstruction: improved image quality with concomitant radiation dose reduction.

    Science.gov (United States)

    Rapalino, O; Kamalian, Shervin; Kamalian, Shahmir; Payabvash, S; Souza, L C S; Zhang, D; Mukta, J; Sahani, D V; Lev, M H; Pomerantz, S R

    2012-04-01

    To safeguard patient health, there is great interest in CT radiation-dose reduction. The purpose of this study was to evaluate the impact of an iterative-reconstruction algorithm, ASIR, on image-quality measures in reduced-dose head CT scans for adult patients. Using a 64-section scanner, we analyzed 100 reduced-dose adult head CT scans at 6 predefined levels of ASIR blended with FBP reconstruction. These scans were compared with 50 CT scans previously obtained at a higher routine dose without ASIR reconstruction. SNR and CNR were computed from Hounsfield unit measurements of normal GM and WM of brain parenchyma. A blinded qualitative analysis was performed in 10 lower-dose CT datasets compared with higher-dose ones without ASIR. Phantom data analysis was also performed. Lower-dose scans without ASIR had significantly lower mean GM and WM SNR (P = .003) and similar GM-WM CNR values compared with higher routine-dose scans. However, at ASIR levels of 20%-40%, there was no statistically significant difference in SNR, and at ASIR levels of ≥60%, the SNR values of the reduced-dose scans were significantly higher (P ASIR levels of ≥40% (P ASIR levels ≥60% (P ASIR in adult head CT scans reduces image noise and increases low-contrast resolution, while allowing lower radiation doses without affecting spatial resolution.

  9. Propofol dose and incidence of dreaming during sedation.

    Science.gov (United States)

    Eer, Audrey Singyi; Padmanabhan, Usha; Leslie, Kate

    2009-10-01

    Dreaming is commonly reported after propofol-based sedation. We measured the incidence of dreaming and bispectral index (BIS) values in colonoscopy patients sedated with combinations of propofol, midazolam and fentanyl. Two hundred patients presenting for elective outpatient colonoscopy were sedated with combinations of propofol, midazolam and fentanyl. BIS was monitored throughout the procedure. Patients were interviewed immediately after they emerged from sedation. The primary end point was a report of dreaming during sedation. Ninety-seven patients were administered propofol alone, 44 were administered propofol and fentanyl, 16 were administered propofol and midazolam and 43 were administered propofol, midazolam and fentanyl. Dreaming was reported by 19% of patients. Dreamers received higher doses of propofol and had lower BIS values during sedation. Age of 50 years or less, preoperative quality of recovery score of less than 14, higher home dream recall, propofol dose of more than 300 mg and time to Observers' Assessment of Alertness/Sedation score equalling 5 of 8 min or less were independent predictors of dreaming. Dreaming during sedation is associated with higher propofol dose and lower BIS values.

  10. Structural changes in mammalian cell DNA induced by low-dose x-ray damage and subsequent postirradiation incubation in the presence and absence of caffeine

    International Nuclear Information System (INIS)

    Wun, K.L.W.; Shafer, R.H.

    1982-01-01

    DNA damage and postirradiation incubation effects from X-ray doses of 30-2000 rad delivered to rat 9L cells in vitro were detemined by viscoelastic analysis of neutral (pH 7) cell lysates. Damage studies showed first an increase in the principal viscoelastic retardation time, T, with increasing dose, followed by a decrease, with the maximum retardation time occurring at 1000 rad. Also, the variation of retardation time with increasing postirradiation incubation time at 37 0 C was determined. At doses greater than 50 rad, this variation was quite complicated; e.g., following 100 rad, the retardation time showed a minimum followed by a maximum as a function of incubation time. All doses showed an initial return of T to close to control values at early times. Following 50 rad, control viscoelastic behavior was recovered in 1 hr. For doses of 100 rad and higher, 5 hr or more were required for complete return to control behavior has determined by both the value of T and the viscoelastic response to a probe dose of 200 rad immediately prior to lysis. These results are analyzed in terms of the dependence of the principal retardation time T on DNA molecular weight and conformation. Evidence is discussed indicating that the observed changes in T during postirradiation incubation reflect repair of DNA damage. Postirradiation incubation in the presence of 0.5 mM caffeine appeared to result in an inhibition of repair. In this case, both 30- and 50-rad doses required 5 hr for complete recovery of control behavior and showed the minimum and maximum in the T vs incubation time curve observed for incubation in the absence of caffeine following a dose of 100 rad

  11. Radiation doses to patients from x-ray examinations - development from 2005 to 2008

    International Nuclear Information System (INIS)

    Leitz, Wolfram; Almen, Anja

    2010-04-01

    Data has been compiled and analyzed and compared with the earlier reports. Radiation doses were tested for possible links with various parameters (eg type of x-ray equipment, image recording systems, different technique factors). In conventional x-ray examinations radiation doses were, for equipment with direct digital image receivers, in average 30% lower than for those with photo plates. Mammography doses were, with one exception, the same for all types of equipment and video receivers. The CT-examinations had a small trend for higher doses for new equipment as compared to earlier. Use of exposure automation did not affect radiation doses. Compared with 2006, the doses of conventional surveys decreased by an average of 21%. One third of this dose reduction can be attributed the introduction of direct digital system whose use grew by about 30%. Most of the dose reduction can be attributed to the actions carried out to lower the dose of the reference level. Doses for the CT scan showed only a weak downwards trend. Mammography Doses decreased by an average of just over 10% a large part dependent on increased number of Sectra equipment. The system of diagnostic reference levels have again shown to have positive influence on the radiation level at the x-ray examinations, this is most pronounced for conventional radiography. There is still a large potential for dose reduction, and a measure to achieve this is to reduce the current reference levels. Very few diagnostic Standard doses are higher than the reference level. A reduction of the reference levels corresponding to the third quartile of dose distribution could lead further dose decrease of 10-20%. The corresponding reduction in dose should be done also for the DT and mammograms when lowering the reference level, there are few standard doses higher than the current reference levels

  12. A prospective, open-label study of low-dose total skin electron beam therapy in mycosis fungoides

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Specht, Lena; Skovgaard, Gunhild L

    2008-01-01

    causes and did not complete treatment. Acute side effects included desquamation, xerosis, and erythema of the skin. No severe side effects were observed. CONCLUSION: Low-dose total skin electron beam therapy can induce complete and partial responses in Stage IB-II mycosis fungoides; however, the duration......PURPOSE: To determine the effect of low-dose (4 Gy) total skin electron beam therapy as a second-line treatment of Stage IB-II mycosis fungoides in a prospective, open-label study. METHODS AND MATERIALS: Ten patients (6 men, 4 women, average age 68.7 years [range, 55-82 years......]) with histopathologically confirmed mycosis fungoides T2-T4 N0-N1 M0 who did not achieve complete remission or relapsed within 4 months after treatment with psoralen plus ultraviolet-A were included. Treatment consisted of low-dose total skin electron beam therapy administered at a total skin dose of 4 Gy given in 4...

  13. Completeness in Hybrid Type Theory

    DEFF Research Database (Denmark)

    Areces, Carlos; Blackburn, Patrick Rowan; Huertas, Antonia

    2014-01-01

    We show that basic hybridization (adding nominals and @ operators) makes it possible to give straightforward Henkin-style completeness proofs even when the modal logic being hybridized is higher-order. The key ideas are to add nominals as expressions of type t, and to extend to arbitrary types th......-style intensional models; we build, as simply as we can, hybrid logicover Henkin’s logic...

  14. In vitro and in vivo effects of low dose HTO contamination modulated by dose rate

    International Nuclear Information System (INIS)

    Petcu, I.; Savu, D.; Moisoi, N.; Koeteles, G.J.

    1997-01-01

    The experiment performed in vitro intended to examine whether an adaptive response could be elicited on lymphocytes by low-level contamination of whole blood with tritiated water and if the modification of the dose rate has any influence on it. Lymphocytes pre-exposed to 3 HOH (0.2 - 6.6 MBq/ml) and subsequently irradiated with I Gy γ-rays showed micronuclei frequency significantly lower (40% - 45%) than the expected member (sum of the yields induced by 3 HOH and γ-rays separately). The degree of the radioresistance induced by HTO pre-treatments became higher with decreasing dose-rate for a rather similar total adapting dose. In vivo, the aim of the study was to investigate if different dose rates are inducing modulation of the lipid peroxidation level and of the thymidine uptake in different tissues of animals contaminated by HTO ingestion. The total doses varied between 5 and 20 cGy and were delivered as chronic (100 days) or acute contamination (5 days). It was observed that only doses about 20 cGy caused a dose-rate dependent increase of the lipid peroxidation level in the tissues of small intestine, kidney and spleen. Both chronic and acute contamination did produce reduced incorporation of thymidine in the cells of bone marrow. The most effective decrease of thymidine uptake was induced by the acute contamination in the lower dose domain (approx. 5 cGy). Our hypothesis is that in this dose domain the modification of thymidine uptake could be due to changes at the level of membrane transport. (author)

  15. Harderian Gland Tumorigenesis: Low-Dose and LET Response

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Polly Y. [SRI International, Menlo Park, CA (United States). Biosciences Div.; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Life Sciences Div.; Cucinotta, Francis A. [Univ. of Nevada, Las Vegas, NV (United States). Dept. of Health Physics and Diagnostic Sciences; Bjornstad, Kathleen A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Life Sciences Div.; Bakke, James [SRI International, Menlo Park, CA (United States). Biosciences Div.; Rosen, Chris J. [SRI International, Menlo Park, CA (United States). Biosciences Div.; Du, Nicholas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Life Sciences Div.; Fairchild, David G. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Life Sciences Div.; Cacao, Eliedonna [Univ. of Nevada, Las Vegas, NV (United States). Dept. of Health Physics and Diagnostic Sciences; Blakely, Eleanor A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Life Sciences Div.

    2016-04-19

    Increased cancer risk remains a primary concern for travel into deep space and may preclude manned missions to Mars due to large uncertainties that currently exist in estimating cancer risk from the spectrum of radiations found in space with the very limited available human epidemiological radiation-induced cancer data. Existing data on human risk of cancer from X-ray and gamma-ray exposure must be scaled to the many types and fluences of radiations found in space using radiation quality factors and dose-rate modification factors, and assuming linearity of response since the shapes of the dose responses at low doses below 100 mSv are unknown. The goal of this work was to reduce uncertainties in the relative biological effect (RBE) and linear energy transfer (LET) relationship for space-relevant doses of charged-particle radiation-induced carcinogenesis. The historical data from the studies of Fry et al. and Alpen et al. for Harderian gland (HG) tumors in the female CB6F1 strain of mouse represent the most complete set of experimental observations, including dose dependence, available on a specific radiation-induced tumor in an experimental animal using heavy ion beams that are found in the cosmic radiation spectrum. However, these data lack complete information on low-dose responses below 0.1 Gy, and for chronic low-dose-rate exposures, and there are gaps in the LET region between 25 and 190 keV/μm. In this study, we used the historical HG tumorigenesis data as reference, and obtained HG tumor data for 260 MeV/u silicon (LET ~70 keV/μm) and 1,000 MeV/u titanium (LET ~100 keV/μm) to fill existing gaps of data in this LET range to improve our understanding of the dose-response curve at low doses, to test for deviations from linearity and to provide RBE estimates. Animals were also exposed to five daily fractions of 0.026 or 0.052 Gy of 1,000 MeV/u titanium ions to simulate chronic exposure, and HG tumorigenesis from this fractionated study were compared to the

  16. Contralateral breast doses measured by film dosimetry: tangential techniques and an optimized IMRT technique

    International Nuclear Information System (INIS)

    Saur, S; Frengen, J; Fjellsboe, L M B; Lindmo, T

    2009-01-01

    The contralateral breast (CLB) doses for three tangential techniques were characterized by using a female thorax phantom and GafChromic EBT film. Dose calculations by the pencil beam and collapsed cone algorithms were included for comparison. The film dosimetry reveals a highly inhomogeneous dose distribution within the CLB, and skin doses due to the medial fields that are several times higher than the interior dose. These phenomena are not correctly reproduced by the calculation algorithms. All tangential techniques were found to give a mean CLB dose of approximately 0.5 Gy. All wedged fields resulted in higher CLB doses than the corresponding open fields, and the lateral open fields resulted in higher CLB doses than the medial open fields. More than a twofold increase in the mean CLB dose from the medial open field was observed for a 90 deg. change of the collimator orientation. Replacing the physical wedge with a virtual wedge reduced the mean dose to the CLB by 35% and 16% for the medial and lateral fields, respectively. Lead shielding reduced the skin dose for a tangential technique by approximately 50%, but the mean CLB dose was only reduced by approximately 11%. Finally, a technique based on open medial fields in combination with several IMRT fields is proposed as a technique for minimizing the CLB dose. With and without lead shielding, the mean CLB dose using this technique was found to be 0.20 and 0.27 Gy, respectively.

  17. Advanced prostate cancer: the results of a randomized comparative trial of high dose irradiation boosting with conformal protons compared with conventional dose irradiation using photons alone

    Energy Technology Data Exchange (ETDEWEB)

    Shipley, William U; Verhey, Lynn J; Munzenrider, John E; Suit, Herman D; Urie, Marcia M; McManus, Patricia L; Young, Robert H; Shipley, Jenot W; Zietman, Anthony L; Biggs, Peter J; Heney, Niall M; Goitein, Michael

    1995-04-30

    Purpose: Following a thorough Phase I/II study, we evaluated by a Phase III trial high versus conventional dose external beam irradiation as mono-therapy for patients with Stage T3-T4 prostate cancer. Patient outcome following standard dose radiotherapy or following a 12.5% increase in total dose to 75.6 Cobalt Gray Equivalent (CGE) using a conformal perineal proton boost was compared for local tumor control, disease-free survival, and overall survival. Methods and Materials: Stage T3-T4, Nx, N0-2, M0 patients received 50.4 Gy by four-field photons and were randomized to receive either an additional 25.2 CGE by conformal protons (arm 1--the high dose arm, 103 patients, total dose 75.6 CGE) or an additional 16.8 Gy by photons (arm 2--the conventional dose arm, 99 patients, total dose 67.2 Gy). Actuarial overall survival (OS), disease-specific survival (DSS), total recurrence-free survival (TRFS), (clinically free, prostate specific antigen (PSA) less than 4ng/ml and a negative prostate rebiopsy, done in 38 patients without evidence of disease) and local control (digital rectal exam and rebiopsy negative) were evaluated. Results: The protocol completion rate was 90% for arm 1 and 97% for arm 2. With a median follow-up of 61 months (range 3 to 139 months) 135 patients are alive and 67 have died, 20 from causes other than prostate cancer. We found no significant differences in OS, DSS, TRFS or local control between the two arms. Among those completing randomized treatment (93 in arm 1 and 96 in arm 2), the local control at 5 and 8 years for arm 1 is 92% and 77%, respectively and is 80% and 60%, respectively for arm 2 (p = .089) and there are no significant differences in OS, DSS, and TRFS. The local control for the 57 patients with poorly differentiated (Gleason 4 or 5 of 5) tumors at 5 and 8 years for arm 1 is 94% and 84% and is 64% and 19% on arm 2 (p 0.0014). In patients whose digital rectal exam had normalized following treatment and underwent prostate rebiopsy

  18. Advanced prostate cancer: the results of a randomized comparative trial of high dose irradiation boosting with conformal protons compared with conventional dose irradiation using photons alone

    International Nuclear Information System (INIS)

    Shipley, William U.; Verhey, Lynn J.; Munzenrider, John E.; Suit, Herman D.; Urie, Marcia M.; McManus, Patricia L.; Young, Robert H.; Shipley, Jenot W.; Zietman, Anthony L.; Biggs, Peter J.; Heney, Niall M.; Goitein, Michael

    1995-01-01

    Purpose: Following a thorough Phase I/II study, we evaluated by a Phase III trial high versus conventional dose external beam irradiation as mono-therapy for patients with Stage T3-T4 prostate cancer. Patient outcome following standard dose radiotherapy or following a 12.5% increase in total dose to 75.6 Cobalt Gray Equivalent (CGE) using a conformal perineal proton boost was compared for local tumor control, disease-free survival, and overall survival. Methods and Materials: Stage T3-T4, Nx, N0-2, M0 patients received 50.4 Gy by four-field photons and were randomized to receive either an additional 25.2 CGE by conformal protons (arm 1--the high dose arm, 103 patients, total dose 75.6 CGE) or an additional 16.8 Gy by photons (arm 2--the conventional dose arm, 99 patients, total dose 67.2 Gy). Actuarial overall survival (OS), disease-specific survival (DSS), total recurrence-free survival (TRFS), (clinically free, prostate specific antigen (PSA) less than 4ng/ml and a negative prostate rebiopsy, done in 38 patients without evidence of disease) and local control (digital rectal exam and rebiopsy negative) were evaluated. Results: The protocol completion rate was 90% for arm 1 and 97% for arm 2. With a median follow-up of 61 months (range 3 to 139 months) 135 patients are alive and 67 have died, 20 from causes other than prostate cancer. We found no significant differences in OS, DSS, TRFS or local control between the two arms. Among those completing randomized treatment (93 in arm 1 and 96 in arm 2), the local control at 5 and 8 years for arm 1 is 92% and 77%, respectively and is 80% and 60%, respectively for arm 2 (p = .089) and there are no significant differences in OS, DSS, and TRFS. The local control for the 57 patients with poorly differentiated (Gleason 4 or 5 of 5) tumors at 5 and 8 years for arm 1 is 94% and 84% and is 64% and 19% on arm 2 (p 0.0014). In patients whose digital rectal exam had normalized following treatment and underwent prostate rebiopsy

  19. Experiences of occupational dose reduction at the Fugen nuclear power station

    International Nuclear Information System (INIS)

    Suzuki, Kazuya; Nakao, Hiromi; Naoi, Yohsuke; Takei, Hiroaki

    1992-01-01

    Occupational radiation dose has been effectively suppressed by efforts against both internal and external exposure in the Fugen nuclear power station. The tritium internal dose is completely suppressed by developments of high sensitivity tritium monitors with hollow fiber radon filters, comfortable tritium protection suits, and established working procedure for equipment maintenance of the heavy water system. The internal occupational dose has been suppressed to a negligible level comparing to the external dose. The external occupational dose had increased with dose rates of the primary cooling system. Establishment of radiation work procedure for maintenance works and development of chemical decontamination has been effectively saving the external occupational dose. The chemical decontaminations carried out in 1989 and 1991 are the first applications to the whole primary cooling system of operating power stations in Japan. This paper describes these efforts and effects on occupational dose reduction in Fugen. (author)

  20. Influence of Genotype on Warfarin Maintenance Dose Predictions Produced Using a Bayesian Dose Individualization Tool.

    Science.gov (United States)

    Saffian, Shamin M; Duffull, Stephen B; Roberts, Rebecca L; Tait, Robert C; Black, Leanne; Lund, Kirstin A; Thomson, Alison H; Wright, Daniel F B

    2016-12-01

    A previously established Bayesian dosing tool for warfarin was found to produce biased maintenance dose predictions. In this study, we aimed (1) to determine whether the biased warfarin dose predictions previously observed could be replicated in a new cohort of patients from 2 different clinical settings, (2) to explore the influence of CYP2C9 and VKORC1 genotype on predictive performance of the Bayesian dosing tool, and (3) to determine whether the previous population used to develop the kinetic-pharmacodynamic model underpinning the Bayesian dosing tool was sufficiently different from the test (posterior) population to account for the biased dose predictions. The warfarin maintenance doses for 140 patients were predicted using the dosing tool and compared with the observed maintenance dose. The impact of genotype was assessed by predicting maintenance doses with prior parameter values known to be altered by genetic variability (eg, EC50 for VKORC1 genotype). The prior population was evaluated by fitting the published kinetic-pharmacodynamic model, which underpins the Bayesian tool, to the observed data using NONMEM and comparing the model parameter estimates with published values. The Bayesian tool produced positively biased dose predictions in the new cohort of patients (mean prediction error [95% confidence interval]; 0.32 mg/d [0.14-0.5]). The bias was only observed in patients requiring ≥7 mg/d. The direction and magnitude of the observed bias was not influenced by genotype. The prior model provided a good fit to our data, which suggests that the bias was not caused by different prior and posterior populations. Maintenance doses for patients requiring ≥7 mg/d were overpredicted. The bias was not due to the influence of genotype nor was it related to differences between the prior and posterior populations. There is a need for a more mechanistic model that captures warfarin dose-response relationship at higher warfarin doses.

  1. Curcumin upregulates S100 expression and improves regeneration of the sciatic nerve following its complete amputation in mice

    Directory of Open Access Journals (Sweden)

    Guo-min Liu

    2016-01-01

    Full Text Available The repair of peripheral nerve injury after complete amputation is difficult, and even with anastomosis, the rapid recovery of nerve function remains challenging. Curcumin, extracted from plants of the genus Curcuma, has been shown to have anti-oxidant and anti-inflammatory properties and to improve sciatic nerve crush injury in rats. Here, we determined whether curcumin had neuroprotective effects following complete peripheral nerve amputation injury. BALB/c mice underwent complete sciatic nerve amputation, followed by an immediate epineurium anastomosis. Mice were intragastrically administered curcumin at doses of 40 (high, 20 (moderate, and 10 mg/kg/d (low for 1 week. We found that myelin in the mice of the high- and moderate-dose curcumin groups appeared with regular shape, uniform thickness, clear boundary, and little hyperplasia surrounding the myelin. High and moderate doses of curcumin markedly improved both action potential amplitude of the sciatic nerves and the conduction velocity of the corresponding motor neurons, and upregulated mRNA and protein expression of S100, a marker for Schwann cell proliferation, in L4–6 spinal cord segments. These results suggest that curcumin is effective in promoting the repair of complete sciatic nerve amputation injury and that the underlying mechanism may be associated with upregulation of S100 expression.

  2. Low and moderate doses of caffeine late in exercise improve performance in trained cyclists.

    Science.gov (United States)

    Talanian, Jason L; Spriet, Lawrence L

    2016-08-01

    The aim of the present study was to assess if low and moderate doses of caffeine delivered in a carbohydrate-electrolyte solution (CES) late in exercise improved time-trial (TT) performance. Fifteen (11 male, 4 female) cyclists (age, 22.5 ± 0.9 years; body mass, 69.3 ± 2.6 kg; peak oxygen consumption, 64.6 ± 1.9 mL·min(-1)·kg(-1)) completed 4 double-blinded randomized trials. Subjects completed 120 min of cycling at ∼60% peak oxygen consumption with 5 interspersed 120-s intervals at ∼82% peak oxygen consumption, immediately followed by 40-s intervals at 50 W. Following 80 min of cycling, subjects either ingested a 6% CES (PL), a CES with 100 mg (low dose, 1.5 ± 0.1 mg·kg body mass(-1)) of caffeine (CAF1), or a CES with 200 mg (moderate dose, 2.9 ± 0.1 mg·kg body mass(-1)) of caffeine (CAF2). Following the 120-min cycling challenge, cyclists completed a 6-kJ·kg body mass(-1) TT. There was no difference between respiratory, heart rate, glucose, free fatty acid, body mass, hematocrit, or urine specific gravity measurements between treatments. The CAF2 (26:36 ± 0:22 min:s) TT was completed faster than CAF1 (27:36 ± 0:32 min:s, p caffeine delivered late in exercise improved TT performance over the PL trial and the moderate dose (CAF2) improved performance to a greater extent than the low dose (CAF1).

  3. On higher derivative gravity

    International Nuclear Information System (INIS)

    Accioly, A.J.

    1987-01-01

    A possible classical route conducting towards a general relativity theory with higher-derivatives starting, in a sense, from first principles, is analysed. A completely causal vacuum solution with the symmetries of the Goedel universe is obtained in the framework of this higher-derivative gravity. This very peculiar and rare result is the first known vcuum solution of the fourth-order gravity theory that is not a solution of the corresponding Einstein's equations.(Author) [pt

  4. A Randomized Dose-Ranging Study of Neuropeptide Y in Patients with Posttraumatic Stress Disorder.

    Science.gov (United States)

    Sayed, Sehrish; Van Dam, Nicholas T; Horn, Sarah R; Kautz, Marin M; Parides, Michael; Costi, Sara; Collins, Katherine A; Iacoviello, Brian; Iosifescu, Dan V; Mathé, Aleksander A; Southwick, Steven M; Feder, Adriana; Charney, Dennis S; Murrough, James W

    2018-01-01

    Anxiety and trauma-related disorders are among the most prevalent and disabling medical conditions in the United States, and posttraumatic stress disorder in particular exacts a tremendous public health toll. We examined the tolerability and anxiolytic efficacy of neuropeptide Y administered via an intranasal route in patients with posttraumatic stress disorder. Twenty-six individuals were randomized in a cross-over, single ascending dose study into 1 of 5 cohorts: 1.4 mg (n=3), 2.8 mg (n=6), 4.6 mg (n=5), 6.8 mg (n=6), and 9.6 mg (n=6). Each individual was dosed with neuropeptide Y or placebo on separate treatment days 1 week apart in random order under double-blind conditions. Assessments were conducted at baseline and following a trauma script symptom provocation procedure subsequent to dosing. Occurrence of adverse events represented the primary tolerability outcome. The difference between treatment conditions on anxiety as measured by the Beck Anxiety Inventory and the State-Trait Anxiety Inventory immediately following the trauma script represented efficacy outcomes. Twenty-four individuals completed both treatment days. Neuropeptide Y was well tolerated up to and including the highest dose. There was a significant interaction between treatment and dose; higher doses of neuropeptide Y were associated with a greater treatment effect, favoring neuropeptide Y over placebo on Beck Anxiety Inventory score (F1,20=4.95, P=.038). There was no significant interaction for State-Trait Anxiety Inventory score. Our study suggests that a single dose of neuropeptide Y is well tolerated up to 9.6 mg and may be associated with anxiolytic effects. Future studies exploring the safety and efficacy of neuropeptide Y in stress-related disorders are warranted. The reported study is registered at: http://clinicaltrials.gov (ID: NCT01533519). © The Author(s) 2017. Published by Oxford University Press on behalf of CINP.

  5. Characteristics of repair following very low doses

    International Nuclear Information System (INIS)

    Braby, L.A.; Metting, N.F.; Nelson, J.M.

    1987-01-01

    The effects of ionizing radiation on living systems being with the physical processes of energy deposition and develop through many stages of chemical reaction and biological response. The modeling effort attempts to organize the available data and theories of all of these stages into self-consistent models that can be compared and tested. In some cases, important differences among models result in only small differences in cell survival within the ranges of dose and dose rate that are normally investigated. To overcome this limitation, new ways of irradiating cells at extremes of dose rate, or ways of evaluating the effects of very small doses, are developed. Mathematical modeling and cellular studies complement each other. It has recently been found that some mechanisms are not adequate to account for the interaction of dose and repair time as they affect the reproductive survival of plateau-phase Chinese hamster ovary (CHO) cells. Repair of radiation-induced cellular damage plays a central role in the survival of cells exposed to doses of 1 Gy or more. This repair is responsible for the dose rate, split-dose and delayed plating effect and can be evaluated. Because split-dose and dose-rate experiments involve repair during irradiation and delayed plating experiments involve repair after irradiation is completed, it was originally thought that different repair processes were involved. It is now clear that this is not necessarily the case. Appropriately designed models can account for observed effects at conventional doses (1 Gy or more) whether they assume all damage is lethal unless repaired or some damage is innocuous unless it interacts with additional damage. The fact that the survival following a plating delay is always less than the survival following immediate plating at low doses indicates that the damage produced is probably not potentially lethal

  6. Effect of low-dose atropine administration on dobutamine dose requirement in horses anesthetized with detomidine and halothane.

    Science.gov (United States)

    Weil, A B; Keegan, R D; Greene, S A

    1997-12-01

    To determine whether a low dose of atropine is associated with decreased requirement for cardiovascular supportive treatment in horses given detomidine prior to maintenance of general anesthesia with halothane. 3 groups of 10 healthy horses. Detomidine (20 micrograms/kg of body weight, i.m.) was administered to all 30 horses. Then, 10 horses received atropine (0.006 mg/kg, i.v.) 1 hour after detomidine administration, 10 horses received atropine (0.012 mg/kg, i.m.) at the time of detomidine administration, and 10 horses served as a control group. Heart rate was measured prior to detomidine administration and at fixed intervals throughout anesthesia. The dobutamine infusion rate necessary to maintain mean arterial blood pressure between 70 and 80 mm of Hg was recorded. Systemic blood pressures, end-tidal halothane, end-tidal CO2, and arterial blood gas tensions were measured at fixed intervals. Mean heart rate was higher among horses receiving atropine i.v. or i.m., compared with that in control horses. Horses that received atropine i.v. had higher systemic arterial blood pressure and required a lower dobutamine infusion rate than did horses of the other groups. Detomidine-treated, halothane-anesthetized horses given atropine i.v. required less dobutamine, compared with horses receiving or not receiving atropine i.m. Complications, such as colic and dysrhythmias, from use of higher doses of atropine, were not observed at this lower dose of atropine. i.v. administration of a low dose of atropine prior to induction of general anesthesia may result in improved blood pressure in horses that have received detomidine before anesthesia with halothane.

  7. Nonrandomized study comparing the effects of preoperative radiotherapy and daily administration of low-dose cisplatin with those radiotherapy alone for oral cancer

    International Nuclear Information System (INIS)

    Kurita, Hiroshi; Azegami, Takuya; Kobayashi, Hirokazu; Kurashina, Kenji; Tanaka, Kouichi; Kotani, Akira; Oguchi, Masahiko; Tamura, Minoru.

    1997-01-01

    The purpose of this study was to compare the effect of preoperative radiotherapy and daily administration of low-dose cisplatin with those of radiotherapy alone for oral cancer. Ten patients underwent preoperative radiotherapy of 30 to 40 Gy with concomitant daily administration of low-dose cisplatin (5 mg/body or 5 mg/m 2 ). Ten patients received external radiotherapy alone. The locoregional response rates (complete response and partial response) did not differ significantly between the two groups (80% for combined therapy and 60% for radiotherapy alone). On histopathologic evaluation of surgical specimens, however, the combined-therapy group (80%) had a higher response rate than did the radiotherapy-alone group (10%; p<0.01). We conclude that daily administration of low-dose cisplatin enhances the efficacy of radiotherapy against primary tumors. We also suggested that combined therapy may be beneficial as an initial treatment for oral cancer before a planned operation. (author)

  8. X-raying with low dose irradiation

    International Nuclear Information System (INIS)

    Malevich, E.E.; Kisel, E.M.; Shpita, I.D.; Lazovsky, A.S.

    2001-01-01

    with higher frequency of a pulsation the share of unproductive radiation is higher. At x-raying controlled by the grid pulses are generated by the x-ray tube with the grid control. The grid, located between the cathode and the anode, passes the electron cloud without the expenses of time for dispersal and attenuation. It gives sharply outlined, rectangular x-ray pulses with homogeneous quality of radiation. Function GC F -x-raying controlled by the grid - enables to receive precisely outlined contours of moving objects: a heart, a gullet, - and also to carry out examination of the children without information loss during simultaneous dose decrease. Besides the image remains precise even during the movement of the electron-optical converter. Owing to radiation parameters adjustment during the examination the effect of the lighted image is eliminated. X-raying devices Easy Diagnose and Diagnose-76 'Philips' are equipped with the system of digital x-ray image processing besides they are completed with the x-ray tube with Grid Controlled Fluoroscopy that allows to carry out pulse x-raying with number of pulses 2, 3, 6 and 12 per a second. So, with 12 pulses per second the irradiation dose in comparison with continuous radiation decreases on 40%. The examinations of a chest, gullet, stomach and thick gut were carried out at the frequency of 12 and 6 pulses per second. In the hospital of the Ministry of Internal Affairs where device Easy Diagnose is established, at examinations of a gastro enteric path (stomach x-raying, irrigoscopy) usually pulse x-raying is used with frequency 12 pulses per second. It allows significantly reduce the beam load on a patient. The calculation of beam loads on a patient was carried out on the basis of exposition dose level at the beam input in the body of a patient (entrance dose). The way is applied for especially exact calculations, as definitions of effective doses on separate organs and all body are difficult. The irradiation dose is in

  9. Dose-response curves from incomplete data

    International Nuclear Information System (INIS)

    Groer, P.G.

    1978-01-01

    Frequently many different responses occur in populations (animal or human) exposed to ionizing radiation. To obtain a dose-response curve, the exposed population is first divided into sub-groups whose members received the same radiation dose. To estimate the response, the fraction of subjects in each sub-group that showed the particular response of interest is determined. These fractions are plotted against dose to give the dose-response curve. This procedure of plotting the fractions versus the radiation dose is not the correct way to estimate the time distribution for a particular response at the different dose levels. Other observed responses competed for the individuals in the exposed population and therefore prevented manifestation of the complete information on the response-time distribution for one specific response. Such data are called incomplete in the statistical literature. A procedure is described which uses the by now classical Kaplan-Meier estimator, to establish dose-response curves from incomplete data under the assumption that the different observed responses are statistically independent. It is demonstrated that there is insufficient information in the observed survival functions to estimate the time distribution for one particular response if the assumption of independence is dropped. In addition, it is not possible to determine from the data (i.e. type of response and when it occurred) whether or not the different response-time distributions are independent. However, it is possible to give sharp bounds between which the response has to lie. This implies that for incomplete data, only a 'dose-response band' can be established if independence of the competing responses cannot be assumed. Examples are given using actual data to illustrate the estimation procedures

  10. A Monte Carlo Study of dose enhancement according to the enhancement agents

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hoon; Kim, Chang Soo [Dept. of Radiological Science, College of Health Sciences, Catholic University of Pusan, Busan (Korea, Republic of); Hwang, Chul Hwan [Dept. of Radiation Oncology, Pusan National University Hospital, Busan (Korea, Republic of)

    2017-03-15

    Dose enhancement effects at megavoltage (MV) X and γ-ray energies, and the effects of different energy levels on incident energy, dose enhancement agents, and concentrations were analyzed using Monte Carlo simulations. Gold, gadolinium, Iodine, and iron oxide (Fe2O3) were compared as dose enhancement agents. For incident energy, 4, 6, 10 and 15 MV X-ray spectra produced by a linear accelerator and a Co60 γ-ray were used. The dose enhancement factor (DEF) was calculated using an ICRU Slab phantom for concentrations of 7, 18, and 30 mg/g. The DEF was higher at higher concentrations of dose enhancement agents and at lower incident energies. The calculated DEF ranged from 1.035 to 1.079, and dose enhancement effects were highest for iron oxide, followed by iodine, gadolinium, and gold. Thus, this study contributes to improving the therapeutic ratio by delivering larger doses of radiation to tumor volume, and provides data to support further in vivo and in vitro studies.

  11. Efficacy of Low-dose (2 millicurie) versus Standard-dose (4 millicurie) Radioiodine Treatment for Cats with Mild-to-Moderate Hyperthyroidism.

    Science.gov (United States)

    Lucy, J M; Peterson, M E; Randolph, J F; Scrivani, P V; Rishniw, M; Davignon, D L; Thompson, M S; Scarlett, J M

    2017-03-01

    Radioiodine ( 131 I) is effective treatment for hyperthyroidism in cats, but optimal dose to restore euthyroidism without inducing hypothyroidism is unclear. Treatment-induced hypothyroidism can lead to azotemia and reduced duration of survival. To compare efficacy and short-term outcomes of low-dose 131 I versus higher, standard-dose 131 I as treatment for hyperthyroidism. A total of 189 client-owned cats undergoing 131 I treatment for mild-to-moderate hyperthyroidism (serum T 4 ≥ 4.0 μg/dL and hyperthyroidism, overt hypothyroidism (low T 4 , high TSH), subclinical hypothyroidism (normal T 4 , high TSH), and azotemia. There was no significant difference in prevalence of cats with persistent hyperthyroidism between standard- and low-dose treatment groups at 3 (0% versus 5.3%; P = .34) and 6 (0% versus 3.3%; P = .51) months. Overt (18% versus 1%; P = .0005) or subclinical (46% versus 21%; P = .004) hypothyroidism was more common in cats at 6 months after standard-dose 131 I. No difference in incidence of azotemia existed between groups, but cats treated with standard-dose 131 I had higher creatinine concentrations (P effective for cats with mild-to-moderate hyperthyroidism, as evidenced by a cure rate of >95% with reduced frequency of iatrogenic hypothyroidism and azotemia. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  12. Asthma Control Can Be Maintained after Fixed-Dose, Budesonide/Formoterol Combination Inhaler Therapy is Stepped Down from Medium to Low Dose

    Directory of Open Access Journals (Sweden)

    Masayuki Hojo

    2013-01-01

    Conclusions: If complete control of asthma, not only of clinical symptoms but also airway inflammation, is achieved by 3-6 months of fixed-dose budesonide/formoterol 4 puffs/day, it should be possible to safely perform step-down to 2 puffs/day.

  13. The limiting dose rate and its importance in radiation protection

    International Nuclear Information System (INIS)

    Bakkiam, D.; Sonwani, Swetha; Arul Ananthakumar, A.; Mohankumar, Mary N.

    2012-01-01

    The concept of defining a low dose of ionizing radiation still remains unclear. Before attempting to define a low dose, it is more important to define a low-dose rate since effects at low dose-rates are different from those observed at higher dose-rates. Hence, it follows that low dose-rates rather than a low dose is an important criteria to determine radio-biological effects and risk factors i.e. stochastic health effects. Chromosomal aberrations induced by ionizing radiations are well fitted by quadratic model Y= áD + âD 2 + C with the linear coefficient of dose predominating for high LET radiations and low doses of low LET. At higher doses and dose rates of sparsely ionizing radiation, break pairs produced by inter-track action leads to the formation of exchange type aberrations and is dependent on dose rate. Whereas at lower doses and dose rates, intra-track action produces break pairs and resulting aberrations are in direct proportion to absorbed dose and independent of dose rate. The dose rate at which inter-track ceases to be observable and where intra-track action effectively becomes the sole contributor of lesion-pair formation is referred to as limiting dose rate (LDR). Once the LDR is reached further reduction in dose rates will not affect the slope of DR since breaks produced by independent charged particle tracks are widely separated in time to interact with each other for aberration yield. This linear dependency is also noticed for acute exposures at very low doses. Existing reports emphasizes the existence of LDR likely to be e6.3cGyh -1 . However no systematic studies have been conducted so far to determine LDR. In the present investigation DR curves were constructed for the dose rates 0.002 and 0.003 Gy/min and to define LDR at which a coefficient approaches zero. Extrapolation of limiting low dose rate data can be used to predict low dose effects regardless of dose rate and its definition ought to serve as a useful index for studies pertaining

  14. Work plan for the Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    1989-12-01

    The primary objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation doses that populations could have received from nuclear operations at the Hanford Site since 1944, with descriptions of uncertainties inherent in such estimates. The secondary objective is to make project records--information that HEDR staff members used to estimate radiation doses--available to the public. Preliminary dose estimates for a limited geographic area and time period, certain radionuclides, and certain populations are planned to be available in 1990; complete results are planned to be reported in 1993. Project reports and references used in the reports are available to the public in the DOE Public Reading Room in Richland, Washington. Project progress is documented in monthly reports, which are also available to the public in the DOE Public Reading Room.

  15. Personal dosimetry statistics and specifics of low dose evaluation

    International Nuclear Information System (INIS)

    Avila, R.E.; Gómez Salinas, R.A.; Oyarzún Cortés, C.H.

    2015-01-01

    The dose statistics of a personal dosimetry service, considering 35,000+ readings, display a sharp peak at low dose (below 0.5 mSv) with skewness to higher values. A measure of the dispersion is that approximately 65% of the doses fall below the average plus 2 standard deviations, an observation which may prove helpful to radiation protection agencies. Categorizing the doses by the concomitant use of a finger ring dosimeter, that skewness is larger in the whole body, and ring dosimeters. The use of Harshaw 5500 readers at high gain leads to frequent values of the glow curve that are judged to be spurious, i.e. values not belonging to the roughly normal noise over the curve. A statistical criterion is shown for identifying those anomalous values, and replacing them with the local behavior, as fit by a cubic polynomial. As a result, the doses above 0.05 mSv which are affected by more than 2% comprise over 10% of the data base. The low dose peak of the statistics, above, has focused our attention on the evaluation of LiF(Mg,Ti) dosimeters exposed at low dose, and read with Harshaw 5500 readers. The standard linear procedure, via an overall reader calibration factor, is observed to fail at low dose, in detailed calibrations from 0.02 mSv to 1 Sv. A significant improvement is achieved by a piecewise polynomials calibration curve. A cubic, at low dose is matched, at ∼10 mSv, in value and first derivative, to a linear dependence at higher doses. This improvement is particularly noticeable below 2 mSv, where over 60% of the evaluated dosimeters are found. (author)

  16. Mammography at reduced doses: present performance and future possibilities

    International Nuclear Information System (INIS)

    Muntz, E.P.; Wilkinson, E.; George, F.W.

    1980-01-01

    Reduced dose mammography is assessed with the aid of very recent work. It is concluded that there are technical and clinical reasons for believing that the reduced dose systems and their interpreters should perform more effectively than their predecessors. Review of known technologic achievements suggests a possible 6 to 7 reduction factor from present screen-film mammography dose levels without sacficifing image quality. Reasonable estimates of representative doses presently achieved by both xeroradiography and screen-film systems are given. The screen-film value is about 3 times higher than some previous

  17. Estimating Effective Dose of Radiation From Pediatric Cardiac CT Angiography Using a 64-MDCT Scanner: New Conversion Factors Relating Dose-Length Product to Effective Dose.

    Science.gov (United States)

    Trattner, Sigal; Chelliah, Anjali; Prinsen, Peter; Ruzal-Shapiro, Carrie B; Xu, Yanping; Jambawalikar, Sachin; Amurao, Maxwell; Einstein, Andrew J

    2017-03-01

    The purpose of this study is to determine the conversion factors that enable accurate estimation of the effective dose (ED) used for cardiac 64-MDCT angiography performed for children. Anthropomorphic phantoms representative of 1- and 10-year-old children, with 50 metal oxide semiconductor field-effect transistor dosimeters placed in organs, underwent scanning performed using a 64-MDCT scanner with different routine clinical cardiac scan modes and x-ray tube potentials. Organ doses were used to calculate the ED on the basis of weighting factors published in 1991 in International Commission on Radiological Protection (ICRP) publication 60 and in 2007 in ICRP publication 103. The EDs and the scanner-reported dose-length products were used to determine conversion factors for each scan mode. The effect of infant heart rate on the ED and the conversion factors was also assessed. The mean conversion factors calculated using the current definition of ED that appeared in ICRP publication 103 were as follows: 0.099 mSv · mGy -1 · cm -1 , for the 1-year-old phantom, and 0.049 mSv · mGy -1 · cm -1 , for the 10-year-old phantom. These conversion factors were a mean of 37% higher than the corresponding conversion factors calculated using the older definition of ED that appeared in ICRP publication 60. Varying the heart rate did not influence the ED or the conversion factors. Conversion factors determined using the definition of ED in ICRP publication 103 and cardiac, rather than chest, scan coverage suggest that the radiation doses that children receive from cardiac CT performed using a contemporary 64-MDCT scanner are higher than the radiation doses previously reported when older chest conversion factors were used. Additional up-to-date pediatric cardiac CT conversion factors are required for use with other contemporary CT scanners and patients of different age ranges.

  18. Cancer radiotherapy based on femtosecond IR laser-beam filamentation yielding ultra-high dose rates and zero entrance dose.

    Science.gov (United States)

    Meesat, Ridthee; Belmouaddine, Hakim; Allard, Jean-François; Tanguay-Renaud, Catherine; Lemay, Rosalie; Brastaviceanu, Tiberius; Tremblay, Luc; Paquette, Benoit; Wagner, J Richard; Jay-Gerin, Jean-Paul; Lepage, Martin; Huels, Michael A; Houde, Daniel

    2012-09-18

    Since the invention of cancer radiotherapy, its primary goal has been to maximize lethal radiation doses to the tumor volume while keeping the dose to surrounding healthy tissues at zero. Sadly, conventional radiation sources (γ or X rays, electrons) used for decades, including multiple or modulated beams, inevitably deposit the majority of their dose in front or behind the tumor, thus damaging healthy tissue and causing secondary cancers years after treatment. Even the most recent pioneering advances in costly proton or carbon ion therapies can not completely avoid dose buildup in front of the tumor volume. Here we show that this ultimate goal of radiotherapy is yet within our reach: Using intense ultra-short infrared laser pulses we can now deposit a very large energy dose at unprecedented microscopic dose rates (up to 10(11) Gy/s) deep inside an adjustable, well-controlled macroscopic volume, without any dose deposit in front or behind the target volume. Our infrared laser pulses produce high density avalanches of low energy electrons via laser filamentation, a phenomenon that results in a spatial energy density and temporal dose rate that both exceed by orders of magnitude any values previously reported even for the most intense clinical radiotherapy systems. Moreover, we show that (i) the type of final damage and its mechanisms in aqueous media, at the molecular and biomolecular level, is comparable to that of conventional ionizing radiation, and (ii) at the tumor tissue level in an animal cancer model, the laser irradiation method shows clear therapeutic benefits.

  19. Patient dose audit of the most frequent radiographic examinations and the proposed local diagnostic reference levels in southwestern Nigeria: Imperative for dose optimisation

    Directory of Open Access Journals (Sweden)

    N.N. Jibiri

    2016-07-01

    Full Text Available Diagnostic reference levels (DRLs is a veritable tool for dose optimisation and patient protection in diagnostic radiology. However, it is essential to have information on the local situation especially in a large hospital with several units or a cluster of healthcare centres within a geographical region with several X-ray units. In the present study, entrance surface doses (ESDs were measured in twelve (12 healthcare centres consisting of 15 radiological units using thermoluminescent dosimeters (TLDs. Seven radiological procedures such as; chest PA, abdomen AP, pelvis AP, lumbar spine AP, skull AP, knee AP, and hand AP frequently carried out in Nigeria were included in the study, and their local diagnostic reference levels (LDRLs were determined. The values of the determined LDRLs were compared with established NDRLs in UK, US, Slovenia, Italy and Brazil. The LDRLs determined in the two groups (healthcare centres studied ranged from 1.78 to 3.01, 2.71 to 2.84, 2.11 to 3.79, 3.93 to 8.79, 1.06 to 1.73 and 1.10 to 1.44 mGy for chest PA, pelvis AP, lumbar spine AP, skull AP, knee AP and hand AP respectively. Large variations were found among the X-ray units studied even within the same centre. Entrance surface doses obtained in pelvis AP and lumbar spine AP in both GROUP A and were found to be lower than the NRPB-HPA 2010 review for UK, while in all other five examinations, value of the measured entrance surface dose (ESD are higher than the doses reported in the UK review. The relative higher doses found in the study are attributable to higher tube load (mAs used and indicative of the need for dose optimisation in Nigerian radiological practice.

  20. Research on dose setting for radiation sterilization of medical device

    International Nuclear Information System (INIS)

    Zhang Tongcheng; Liu Qingfang; Zhong Hongliang; Mi Zhisu; Wang Chunlei; Jiang Jianping

    2002-01-01

    Objective: To establish the radiation sterilization dose for medical devices using data of bioburden on the medical device. Methods: Firstly determination of recovery ratio and correction coefficient of the microbiological test method was used according to ISO11737 standard, then determination of bioburden on the products, finally the dose setting was completed based on the Method 1 in ISO11137 standard. Results: Fifteen kinds of medical devices were tested. Bioburden range was from 8.6-97271.2 CFU/device, recovery ration range 54.6%-100%, correction co-efficiency range 1.00-1.83, D 10 distribution from 1.40 to 2.82 kGy, verification dose (dose at SAL = 10 -2 ) range 5.1-17.6 kGy and sterilization dose (dose at SAL 10 -6 ) range 17.5-32.5 kGy. Conclusion: One hundred samples of each kind of product were exposed to the pre-determined verification dose and then the sterility test was performed. Each sterility test showed positive number was not greater than two. This indicated that the sterilization dose established for each kind of product was statistically acceptable

  1. Expectations and final evaluation of complete dentures by patients, dentist and dental technician.

    Science.gov (United States)

    Marachlioglou, C R M Z; Dos Santos, J F F; Cunha, V P P; Marchini, Leonardo

    2010-07-01

    There is a poor association between the dentist's evaluation of denture quality and patients' satisfaction with their dentures. Possible differences between dental professionals and patients' expectations might help explain differences in outcome evaluations. This study compared scores given by a dentist, a dental technician and patients for their expectations before and their final evaluation after complete dentures treatment. Twenty completely edentulous patients, a prosthodontist and a dental technician provided scores for the expected aesthetic and functional results of their dentures based on a visual analogue scale at baseline. Post-treatment completion ratings were given after adjustments, by dentist and patients. The dental technician provided post-treatment completion ratings after completing the dentures. The patients had higher expectations than the dental technician and the dentist perceived for both aesthetic and function (P < 0.001). The patients also presented higher post-treatment completion ratings than the dental professionals perceived for final aesthetics (P = 0.016, Kendall's W = 0.207) and function (P = 0.002, Kendall's W = 0.303). Only the dentist presented a statistically significant difference between expectations (lower) and final (higher) outcomes for aesthetics (P = 0.017) and function (P = 0.003). There was no correlation between expectations and post-treatment completion ratings according to the patients' age. There was also no correlation between the patients' gender and expectation scores. Patients presented higher expectations regarding their dentures than dental professionals. The dentist believed that dentures would bring fewer benefits than patients did, but his perception of denture benefits post-treatment was significantly higher than his expectations.

  2. Low-Dose Radioactive Iodine Destroys Thyroid Tissue Left after Surgery

    Science.gov (United States)

    A low dose of radioactive iodine given after surgery for thyroid cancer destroyed (ablated) residual thyroid tissue as effectively as a higher dose, with fewer side effects and less exposure to radiation, according to two randomized controlled trials.

  3. Defibrotide for the treatment of severe hepatic veno-occlusive disease and multiorgan failure after stem cell transplantation: a multicenter, randomized, dose-finding trial.

    Science.gov (United States)

    Richardson, Paul G; Soiffer, Robert J; Antin, Joseph H; Uno, Hajime; Jin, Zhezhen; Kurtzberg, Joanne; Martin, Paul L; Steinbach, Gideon; Murray, Karen F; Vogelsang, Georgia B; Chen, Allen R; Krishnan, Amrita; Kernan, Nancy A; Avigan, David E; Spitzer, Thomas R; Shulman, Howard M; Di Salvo, Donald N; Revta, Carolyn; Warren, Diane; Momtaz, Parisa; Bradwin, Gary; Wei, L J; Iacobelli, Massimo; McDonald, George B; Guinan, Eva C

    2010-07-01

    Therapeutic options for severe hepatic veno-occlusive disease (VOD) are limited and outcomes are dismal, but early phase I/II studies have suggested promising activity and acceptable toxicity using the novel polydisperse oligonucleotide defibrotide. This randomized phase II dose-finding trial determined the efficacy of defibrotide in patients with severe VOD following hematopoietic stem cell transplantation (HSCT) and identified an appropriate dose for future trials. Adult and pediatric patients received either lower-dose (arm A: 25 mg/kg/day; n = 75) or higher-dose (arm B: 40 mg/kg/day; n = 74) i.v. defibrotide administered in divided doses every 6 hours for > or =14 days or until complete response, VOD progression, or any unacceptable toxicity occurred. Overall complete response and day +100 post-HSCT survival rates were 46% and 42%, respectively, with no significant difference between treatment arms. The incidence of treatment-related adverse events was low (8% overall; 7% in arm A, 10% in arm B); there was no significant difference in the overall rate of adverse events between treatment arms. Early stabilization or decreased bilirubin was associated with better response and day +100 survival, and decreased plasminogen activator inhibitor type 1 (PAI-1) during treatment was associated with better outcome; changes were similar in both treatment arms. Defibrotide 25 or 40 mg/kg/day also appears effective in treating severe VOD following HSCT. In the absence of any differences in activity, toxicity or changes in PAI-1 level, defibrotide 25 mg/kg/day was selected for ongoing phase III trials in VOD.

  4. Pediatric patient and staff dose measurements in barium meal fluoroscopic procedures

    Science.gov (United States)

    Filipov, D.; Schelin, H. R.; Denyak, V.; Paschuk, S. A.; Porto, L. E.; Ledesma, J. A.; Nascimento, E. X.; Legnani, A.; Andrade, M. E. A.; Khoury, H. J.

    2015-11-01

    This study investigates patient and staff dose measurements in pediatric barium meal series fluoroscopic procedures. It aims to analyze radiographic techniques, measure the air kerma-area product (PKA), and estimate the staff's eye lens, thyroid and hands equivalent doses. The procedures of 41 patients were studied, and PKA values were calculated using LiF:Mg,Ti thermoluminescent dosimeters (TLDs) positioned at the center of the patient's upper chest. Furthermore, LiF:Mg,Cu,P TLDs were used to estimate the equivalent doses. The results showed a discrepancy in the radiographic techniques when compared to the European Commission recommendations. Half of the results of the analyzed literature presented lower PKA and dose reference level values than the present study. The staff's equivalent doses strongly depends on the distance from the beam. A 55-cm distance can be considered satisfactory. However, a distance decrease of ~20% leads to, at least, two times higher equivalent doses. For eye lenses this dose is significantly greater than the annual limit set by the International Commission on Radiological Protection. In addition, the occupational doses were found to be much higher than in the literature. Changing the used radiographic techniques to the ones recommended by the European Communities, it is expected to achieve lower PKA values ​​and occupational doses.

  5. Dose profile variation with voltage in head CT scans using radiochromic films

    Science.gov (United States)

    Mourão, A. P.; Alonso, T. C.; DaSilva, T. A.

    2014-02-01

    The voltage source used in an X-ray tube is an important part of defining the generated beam spectrum energy profile. The X-ray spectrum energy defines the X-ray beam absorption as well as the characteristics of the energy deposition in an irradiated object. Although CT scanners allow one to choose between four different voltage values, most of them employ a voltage of 120 kV in their scanning protocols, regardless of the patient characteristics. Based on this fact, this work investigated the deposited dose in a polymethyl methacrylate (PMMA) cylindrical head phantom. The entire volume was irradiated twice. Two CT scanning protocols were used with two different voltage values: 100 and 120 kV. The phantom volume was irradiated, and radiochromic films were employed to record dose profiles. Measurements were conducted with a calibrated pencil ionization chamber, which was positioned in the center and in four peripheral bores of the head PMMA phantom, to calibrate the radiochromic films. The central slice was then irradiated. This procedure allowed us to find the conversion factors necessary to obtain dose values recorded in the films. The data obtained allowed us to observe the dose variation profile inside the phantom head as well as in the peripheral and central regions. The peripheral region showed higher dose values than those of the central region for scans using both voltage values: approximately 31% higher for scanning with 120 kV and 25% higher with 100 kV. Doses recorded with the highest voltage are significantly higher, approximately 50% higher in the peripheral region and 40% higher in the central region. A longitudinal variation could be observed, and the maximum dose was recorded at the peripheral region, at the midpoint of the longitudinal axis. The obtained results will most likely contribute to the dissemination of proper procedure as well as to optimize dosimetry and tests of quality control in CT because the choice of protocols with different voltage

  6. Peripheral dose outside applicators in electron beams

    International Nuclear Information System (INIS)

    Chow, James C L; Grigorov, Grigor N

    2006-01-01

    The peripheral dose outside the applicators in electron beams was studied using a Varian 21 EX linear accelerator. To measure the peripheral dose profiles and point doses for the applicator, a solid water phantom was used with calibrated Kodak TL films. Peak dose spot was observed in the 4 MeV beam outside the applicator. The peripheral dose peak was very small in the 6 MeV beam and was ignorable at higher energies. Using the 10 x 10 cm 2 cutout and applicator, the dose peak for the 4 MeV beam was about 12 cm away from the field central beam axis (CAX) and the peripheral dose profiles did not change with depths measured at 0.2, 0.5 and 1 cm. The peripheral doses and profiles were further measured by varying the angle of obliquity, cutout and applicator size for the 4 MeV beam. The local peak dose was increased with about 3% per degree angle of obliquity, and was about 1% of the prescribed dose (angle of obliquity equals zero) at 1 cm depth in the phantom using the 10 x 10 cm 2 cutout and applicator. The peak dose position was also shifted 7 mm towards the CAX when the angle of obliquity was increased from 0 to 15 deg. (note)

  7. Radiation tolerance of the cervical spinal cord: incidence and dose-volume relationship of symptomatic and asymptomatic late effects following high dose irradiation of paraspinal tumors

    International Nuclear Information System (INIS)

    Liu, Mitchell C.C.; Munzenrider, John E.; Finkelstein, Dianne; Liebsch, Norbert; Adams, Judy; Hug, Eugen B.

    1997-01-01

    Purpose: Low grade chordomas and chondrosarcomas require high radiation doses for effective, lasting tumor control. Fractionated, 3-D planned, conformal proton radiation therapy has been used for lesions along the base of skull and spine to deliver high target doses, while respecting constraints of critical, normal tissues. In this study, we sought to determine the incidence of myelopathy after high dose radiotherapy to the cervical spine and investigated the influence of various treatment parameters, including dose-volume relationship. Methods and Materials: Between December 1980 and March 1996, 78 patients were treated at the Massachusetts General Hospital and Harvard Cyclotron Laboratory for primary or recurrent chordomas and chondrosarcomas of the cervical spine using combined proton and photon radiation therapy. In general, the tumor dose given was between 64.5 to 79.2 CGE (Cobalt Gray Equivalent). The guidelines for maximum permissible doses to spinal cord were: ≤ 64 CGE to the spinal cord surface and ≤ 53 CGE to the spinal cord center. Dose volume histograms of the spinal cord were analyzed to investigate a possible dose and volume relationship. Results: With a mean follow-up period of 46.6 months (range: 3 - 157 months), 4 of 78 patients (5.1%) developed high-grade (RTOG Grade 3 and 4) late toxicity: 3 patients (3.8%) experienced sensory deficits without motor deficits, none had any limitations of daily activities. One patient (1.2%) developed motor deficit with loss of motor function of one upper extremity. The only patient, who developed permanent motor damage had received additional prior radiation treatment and therefore received a cumulative spinal cord dose higher than the treatment guidelines. No patient treated within the guidelines experienced any motor impairment. Six patients (7.7%) experienced transient Lhermitt's syndrome and 1 patient (1.2%) developed asymptomatic radiographic MR findings only. Time to onset of symptoms of radiographic

  8. Indoor radon levels and inhalation doses in dwellings near the some sites of Himachal Pradesh, India

    International Nuclear Information System (INIS)

    Bajwa, B.S.; Singh, S.; Virk, H.S.

    2005-01-01

    In view of the fact that radon and its daughters are a major source of natural radiation exposure, the measurement of radon concentration levels in dwellings has assumed ever-increasing importance. Keeping this in view, the indoor radon level measurements were carried out in the dwellings of different villages known to be located in the vicinity of uranium-mineralized pockets of Hamirpur district, Himachal Pradesh. Track-etch technique, a passive method using the Solid State Nuclear Track Detectors (SSNTDs), LR-115 type II, was utilized for these measurements. An attempt has been made to assess the levels of the indoor radon in the dwellings and inhalation dose rates of the population living in these villages. The radon concentrations were found to be varying with seasonal changes, building materials and mode of construction of houses. The radon concentrations were found to be higher in houses made from local sandstone and with mud floor in comparison to the houses having cemented brick floors. The annual indoor radon concentration and thus annual effective dose in most of the dwellings of these villages is certainly quite higher and even in some of the dwellings it even exceeds the upper limit of the proposed action level of ICRP, 1993. The inhalation dose rates in dwellings of these villages located in the vicinity of uranium mineralized pockets of Hamirpur district, Himachal Pradesh have been found to be quite higher than dose rate in the dwellings in the Amritsar city, Punjab, which is located in a completely uranium free zone. The radon survey in the dwellings of these villages has also been carried out using the Alpha-Guard technique, which is based on the pulse ionization chamber. The indoor radon concentration levels measured using the active technique of Alpha Guard have been found to be quite different from those measured in these dwellings by the passive technique of SSNTDs; indicating the importance of the SSNTDs in the long-term integrated measurement

  9. Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography.

    Science.gov (United States)

    Trattner, Sigal; Halliburton, Sandra; Thompson, Carla M; Xu, Yanping; Chelliah, Anjali; Jambawalikar, Sachin R; Peng, Boyu; Peters, M Robert; Jacobs, Jill E; Ghesani, Munir; Jang, James J; Al-Khalidi, Hussein; Einstein, Andrew J

    2018-01-01

    This study sought to determine updated conversion factors (k-factors) that would enable accurate estimation of radiation effective dose (ED) for coronary computed tomography angiography (CTA) and calcium scoring performed on 12 contemporary scanner models and current clinical cardiac protocols and to compare these methods to the standard chest k-factor of 0.014 mSv·mGy -1 cm -1 . Accurate estimation of ED from cardiac CT scans is essential to meaningfully compare the benefits and risks of different cardiac imaging strategies and optimize test and protocol selection. Presently, ED from cardiac CT is generally estimated by multiplying a scanner-reported parameter, the dose-length product, by a k-factor which was determined for noncardiac chest CT, using single-slice scanners and a superseded definition of ED. Metal-oxide-semiconductor field-effect transistor radiation detectors were positioned in organs of anthropomorphic phantoms, which were scanned using all cardiac protocols, 120 clinical protocols in total, on 12 CT scanners representing the spectrum of scanners from 5 manufacturers (GE, Hitachi, Philips, Siemens, Toshiba). Organ doses were determined for each protocol, and ED was calculated as defined in International Commission on Radiological Protection Publication 103. Effective doses and scanner-reported dose-length products were used to determine k-factors for each scanner model and protocol. k-Factors averaged 0.026 mSv·mGy -1 cm -1 (95% confidence interval: 0.0258 to 0.0266) and ranged between 0.020 and 0.035 mSv·mGy -1 cm -1 . The standard chest k-factor underestimates ED by an average of 46%, ranging from 30% to 60%, depending on scanner, mode, and tube potential. Factors were higher for prospective axial versus retrospective helical scan modes, calcium scoring versus coronary CTA, and higher (100 to 120 kV) versus lower (80 kV) tube potential and varied among scanner models (range of average k-factors: 0.0229 to 0.0277 mSv·mGy -1 cm -1 ). Cardiac k

  10. An inter-hospital comparison of patient dose based on clinical indications

    International Nuclear Information System (INIS)

    Teeuwisse, W.; Geleijns, J.; Veldkamp, W.

    2007-01-01

    Patient dose is usually estimated for a single radiographic projection or computed tomography (CT) series. In this study, patient dose was calculated for predefined clinical indications (24 radiography, 11 CT). Members of the radiology staff of each of 11 hospitals were trained in dose measurement and calculation techniques. Based on clinical indications participants decided on imaging protocols and calculated cumulative effective dose for a complete examination. Effective dose ranged from <1 μSv to 0.6 mSv for examinations with radiographs and from 0.2 to 12 mSv for CT scans. Differences in the imaging protocols contributedd to a substantial variation in patient dose. For mammography, average glandular dose (AGD) was estimated for 32-, 53- and 90-mm compressed breast thicknesses, with a median value of 0.74, 1.74 and 3.40 mGy, respectively. The results presented here demonstrate that a pragmatic choice of dosimetry methods enables local staff to estimate effective dose. The inclusion of imaging protocols in the dose surveys provided a broader view on the variations in patient dose between hospitals. (orig.)

  11. Correlation between the single, high dose of ingested baclofen and clinical symptoms

    Directory of Open Access Journals (Sweden)

    Jacek Sein Anand

    2017-12-01

    There is a statistically significant correlation between the dose of ingested baclofen and the presence of acute respiratory failure, and duration of mechanical ventilation. Patients who have taken a single dose of baclofen of 200 mg, or higher, should be managed in centres able to provide continuous monitoring of life functions. Those with a higher level of a single dose of baclofen ingestion (>500 mg, should be hospitalized in a Toxicology Unit or Intensive Care Unit able to provide airway support and mechanical ventilation.

  12. Relative safety profiles of high dose statin regimens

    Directory of Open Access Journals (Sweden)

    Carlos Escobar

    2008-06-01

    Full Text Available Carlos Escobar, Rocio Echarri, Vivencio BarriosDepartment of Cardiology, Hospital Ramón y Cajal, Madrid, SpainAbstract: Recent clinical trials recommend achieving a low-density lipoprotein cholesterol level of <100 mg/dl in high-risk and <70 mg/dl in very high risk patients. To attain these goals, however, many patients will need statins at high doses. The most frequent side effects related to the use of statins, myopathy, rhabdomyolysis, and increased levels of transaminases, are unusual. Although low and moderate doses show a favourable profile, there is concern about the tolerability of higher doses. During recent years, numerous trials to analyze the efficacy and tolerability of high doses of statins have been published. This paper updates the published data on the safety of statins at high doses.Keywords: statins, high doses, tolerability, liver, muscle

  13. Prostate cancer: Doses and volumes of radiotherapy

    International Nuclear Information System (INIS)

    Hennequin, C.; Rivera, S.; Quero, L.; Latorzeff, I.

    2010-01-01

    Radiotherapy is nowadays a major therapeutic option in prostate cancer. Technological improvements allowed dose escalation without increasing late toxicity. Some randomized trials have shown that dose escalation decreases the biochemical failure rate, without any benefit in survival with the present follow-up. However, some studies indicate that the distant metastases rate is also decreased. Most of these studies have been done without hormonal treatment, and the role of dose escalation in case of long-term androgen deprivation is unknown. The target volume encompassed the whole gland: however, complete or partial focal treatment of the prostate can be done with sophisticated IMRT technique and must be evaluated. Proximal part of the seminal vesicles must be included in the target volumes. The role of nodal irradiation is another debate, but it could be logically proposed for the unfavourable group. (authors)

  14. Outdoor γ-ray dose rate in Mutsu city and environmental factors affecting outdoor γ-ray dose rate in IES

    International Nuclear Information System (INIS)

    Iyogi, Takashi; Hisamatsu, Shun'ichi; Inaba, Jiro

    2001-01-01

    Previously, we surveyed outdoor γ-ray dose rates throughout Aomori Prefecture from 1992 to 1995, and found a mean annual dose rate of 28 nGy h -1 . Relatively high dose rates were also observed in several areas (municipalities) of the survey locations. In this study, we examined the detailed distribution of the γ-ray dose rate in one such high dose rate area, Mutsu City. Glass dosemeters were used for the monitoring of cumulative γ-ray dose rate at 10 locations in the city. The dose rate from each radioactive nuclide in the ground at the monitoring locations was measured by using an in situ γ-ray spectrometer with a Ge detector. The results obtained with the glass dosemeters showed that the γ-ray dose rates in Mutsu City varied from 17 to 32 nGy h -1 . Although the dose rates were almost the same as the mean dose in Aomori Prefecture (1992-1995), the rates were lower than other high dose rate areas which had already been measured. The in situ γ-ray spectrometry revealed that these relatively high dose rates were mainly caused by 40 K and Th series radionuclides in the local ground. The effect of meteorological conditions on the γ-ray dose rate was studied at a monitoring station in the IES site. The dose rate was continuously recorded by a DBM NaI(Tl) scintillation detector system. The mean dose rate obtained when precipitation was sensed was 26 nGy h -1 and higher than when no precipitation was sensed (24 nGy h -1 ). (author)

  15. Comparison between dose values specified at the ICRU reference point and the mean dose to the planning target volume

    International Nuclear Information System (INIS)

    Kukoowicz, Pawel F.; Mijnheer, Bernard J.

    1997-01-01

    Background and purpose: To compare dose values specified at the reference point, as recommended by the International Commission on Radiation Units and Measurements, ICRU, and the mean dose to the planning target volume, PTV. Material and methods: CT-based dose calculations were performed with a 3-D treatment planning system for 6 series of patients treated for bladder, brain, breast, lung, oropharynx and parotid gland tumour. All patients were arbitrarily chosen from a set of previously treated patients irradiated with a two- or three-field technique using customised blocks. Appropriate wedge angles and beam weights were chosen to make the dose distribution as homogeneous as possible. Results: The dose at the ICRU reference point was generally higher than the mean dose to the PTV. The difference between the ICRU reference dose and the mean dose to the PTV for an individual patient was less than 3% in 88% of cases and less than 2% in 72% of the cases. The differences were larger in those patients where the dose distribution is significantly influenced by the presence of lungs or air gaps. For each series of patients the mean difference between the ICRU reference dose and the mean dose to the PTV was calculated. The difference between these two values never exceeded 2%. Because not all planning systems are able to calculate the mean dose to the PTV, the concept of the mean central dose, the mean of the dose values at the centre of the PTV in each CT slice, has been introduced. The mean central dose was also calculated for the same patients and was closer to the mean dose to the PTV than the ICRU reference dose. Conclusion: The mean dose to the PTV is well estimated by either the ICRU reference dose or the mean central dose for a variety of treatment techniques for common types of cancer

  16. Safety and efficacy of low-dose isotretinoin in the treatment of moderate to severe acne vulgaris

    Directory of Open Access Journals (Sweden)

    Parinitha K Rao

    2014-01-01

    Full Text Available Background: Isotretinoin is indicated for moderate to severe cases of acne which are unresponsive to conventional therapy. The classical recommended dose is 0.5 to 1.0 mg/kg/day. As the side effects are dose related, low-dose isotretinoin therapy for acne is an attractive option; however, but little data exists on the safety and efficacy of this strategy. Materials and Methods: In this prospective, non-comparative study, 50 participants, both male and female, having moderate to severe acne vulgaris were enrolled and treated with isotretinoin at a dose of 20 mg/day (approximately 0.3-0.4 mg/kg/day, for a period of 3 months. Participants were evaluated by means of clinical and laboratory investigations before starting isotretinoin. Investigations were repeated at the end of the first and third months following completion of treatment, and participants were followed up for 6 months to look for any relapse. Results: At the end of the treatment, very good results were observed in 90% of participants. Cheilitis was the most common among the side effects observed and was seen in 98% of the participants. One participant developed vitiligo as a side effect, which is a new finding, and has not reported in literature before. Elevated serum lipid levels were observed in 6% of the participants, and relapse occurred in 4% of the participants over a 6 month follow up period. Conclusion: Three months of treatment with low-dose isotretinoin (20 mg/day was found to be effective in the treatment of moderate to severe acne vulgaris, with a low incidence of serious side effects. This dose also was more economical than the higher doses.

  17. Acoustic neuromas: single dose vs fractionated therapy

    Energy Technology Data Exchange (ETDEWEB)

    Fuss, M; Debus, J; Lohr, F; Engenhart-Cabillic, R; Wannenmacher, M

    1997-07-01

    patients (18%) in the RS group, none of them requiring therapy, but none in the FT group. Hearing impairment improved in 1 case (RS) and 4 cases (FT). Complete hearing loss was diagnosed in 1 case in the FT group but in 3 cases in the RS group (all these patients were treated with 16 Gy or more). One temporary facial nerve weakness was found after FT. Among the RS group treated with {>=}16 Gy, 4 permanent facial nerve lesions were observed with complete facial nerve paresis in 2 patients. Improvement of vertigo or tinnitus was found in 1 patient after FT and in 3 patients treated with RS. If radiosurgical doses were <15 Gy, no severe side effects were observed. Among this group, 6 patients (54%) showed a significant reduction of preexisting neurological dysfunction. Conclusion: Radiosurgical treatment of small acoustic neuromas with doses <15 Gy prescribed to a volume <10 ccm results in excellent tumor control with no relevant toxicity. For fractionated therapy, results are comparable, even if the tumor volume exceeded 10 ccm. Single dose treatment with doses >15 Gy may cause higher toxicity. Fractionated conformal radiotherapy offers effective tumor control and low morbidity especially after contralateral neurosurgical resection of an acoustic neuroma with consecutive hearing loss and/or facial paresis.

  18. Assessment of population external irradiation doses with consideration of Rospotrebnadzor bodies equipment for monitoring of photon radiation dose

    Directory of Open Access Journals (Sweden)

    I. P. Stamat

    2016-01-01

    Full Text Available This paper provides review of equipment and methodology for measurement of photon radiation dose; analysis of possible reasons for considerable deviation between the Russian Federation population annual effective external irradiation doses and the relevant average global value. Data on Rospotrebnadzor bodies dosimetry equipment used for measurement of gamma radiation dose are collected and systematized. Over 60 kinds of dosimeters are used for monitoring of population external irradiation doses. Most of dosimeters used in the country have gas-discharge detectors (Geiger-Mueller counters, minor biochemical annunciators, etc. which have higher total values of own background level and of space radiation response than the modern dosimeters with scintillation detectors. This feature of dosimeters is apparently one of most plausible reasons of a bit overstating assessment of population external irradiation doses. The options for specification of population external irradiation doses assessment are: correction of gamma radiation dose measurement results with consideration of dosimeters own background level and space radiation response, introduction of more up-to-date dosimeters with scintillation detectors, etc. The most promising direction of research in verification of population external irradiation doses assessment is account of dosimetry equipment.

  19. Effects of Wine by-Products on Growth Performance, Complete Blood Count and Total Antioxidant Status in Broilers

    Directory of Open Access Journals (Sweden)

    SM Pascariu

    Full Text Available ABSTRACT This study aimed to investigate the effect of whole grape pomace (GP, grape seed (GS and grape pomace polyphenolic extract (GPEP on growth performance, total antioxidant status (TAS and complete blood count (CBC of 40-day-old chicks (hybrid Cobb 500. A total of 432 unsexed one-day-old chicks were divided into six groups: control (CON and five experimental groups, 10 g/kg GP, 20 g/kg GP, 5 g/kg GS, 10 g/kg GS and 15 mL/L GPEP. The results showed a higher increase in growing rate in 5 g/kg GS group, from the first week of the chicks’ life throughout their growth, the average body weight of the chicks being significantly higher (p0.05 at 40 days of age. As a conclusion, the amount of 5 g/kg seeds, 10 g/kg and 20 g/kg pomace, can be added to the diet of the broilers, the dose of 5 g/kg seeds in the diet offering advantages in growing rate and feed valorization in weight gain.

  20. Implication of fractionated dose exposures in therapeutic gain

    International Nuclear Information System (INIS)

    Kim, Hye-Jin; Lee, Min-Ho; Kim, Eun-Hee

    2016-01-01

    Radiation therapy pursues killing tumor cells while sparing normal cells from the radiation exposure. Stereotactic radiosurgery (SRS) is a cancer treatment modality that delivers a high dose in a single operation. This high-dose single operation shortens the treatment course, but can increase the risk of normal cell damage. Normal cell damage can be reduced by employing multi-directional exposures for an increasing number of isocenters. In this study, we investigated whether therapeutic benefits would be expected by employing new dose fractionation patterns at a high-dose single operation. The conventional single-dose operation in brain tumor radiosurgery is performed by delivering fractionated uniform doses. According to Figs. 2 and 3, the conventional radiosurgery might have obtained some therapeutic benefit by employing the fractionated uniform-dose exposures instead of a single-dose exposure. We suggest that further therapeutic gain be expected by employing the fractionated radiation exposures in an increasing dose pattern. Until ensuring our suggestion, the significance in gain of cell surviving should be verified for all three dose patterns with both normal and tumor cells. The investigation whether normal and tumor cells show the same responses to the fractionated dose exposures at lower and higher than 15 Gy of total dose is also reserved for future work

  1. Morphological changes induced by different doses of gamma irradiation in garlic sprouts

    Energy Technology Data Exchange (ETDEWEB)

    Pellegrini, C.N. E-mail: pellegri@criba.edu.ar; Croci, C.A.; Orioli, G.A

    2000-03-01

    The objective of this work was to evaluate the effects of different doses of gamma rays applied in dormancy and post-dormancy on garlic bulbs in relation with some morphophysiological parameters. High (commercial) doses cause the complete inhibition of sprouting and mitosis (due to nuclear aberrations). Relatively low doses show no effects on bulbs but doses of 10 Gy applied in post-dormancy reduce sprouting and stop mitosis. This inhibition becomes noticeable from 150 days post-harvest onwards. Exogenous growth regulators can reverse these effects. Results may reinforce the good practice of radioinhibition processes in garlic. (author)0.

  2. Low dose iodine-131 therapy in solitary toxic thyroid nodules

    International Nuclear Information System (INIS)

    Prakash, Rajeev

    1999-01-01

    Forty patients with solitary hyperfunctioning thyroid nodules were treated with relatively low dose radioiodine therapy, 131 I doses were calculated taking into account thyroid mass and radioiodine kinetics to deliver 100 μCi/g of estimated nodule weight corrected for uptake. Patients remaining persistently hyperthyroid at four months after the initial therapy were retreated with a similarly calculated dose. Cure of the hyperthyroid state was achieved in all patients, total administered dose in individual cases ranging from 3-17 mCi. 28 of the 40 patients required a single therapy dose. 36 patients were euthyroid after a 4.5 year mean follow-up period. Four cases developed post therapy hypothyroidism requiring replacement therapy. Nodules regressed completely in nine cases following 131 I treatment, with partial regression in size in 19 patients. Control of hyperthyroid state in cases of solitary toxic thyroid nodules can be satisfactorily achieved using relatively low dose radioiodine therapy with low incidence of post therapy hypothyroidism. (author)

  3. Dose tracking and dose auditing in a comprehensive computed tomography dose-reduction program.

    Science.gov (United States)

    Duong, Phuong-Anh; Little, Brent P

    2014-08-01

    Implementation of a comprehensive computed tomography (CT) radiation dose-reduction program is a complex undertaking, requiring an assessment of baseline doses, an understanding of dose-saving techniques, and an ongoing appraisal of results. We describe the role of dose tracking in planning and executing a dose-reduction program and discuss the use of the American College of Radiology CT Dose Index Registry at our institution. We review the basics of dose-related CT scan parameters, the components of the dose report, and the dose-reduction techniques, showing how an understanding of each technique is important in effective auditing of "outlier" doses identified by dose tracking. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Optimized Dose Distribution of Gammamed Plus Vaginal Cylinders

    International Nuclear Information System (INIS)

    Supe, Sanjay S.; Bijina, T.K.; Varatharaj, C.; Shwetha, B.; Arunkumar, T.; Sathiyan, S.; Ganesh, K.M.; Ravikumar, M.

    2009-01-01

    points were higher for the apex model compared with the non-apex model. Mean doses to the optimization points for both the cylinder models and all the cylinder diameters were 6 Gy, matching with the prescription dose of 6 Gy. Iterative optimization routine resulted in the highest dose to apex point and dome points. The mean dose for optimization point was 6.01 Gy for iterative optimization and was much higher than 5.74 Gy for geometric and equal times routines. Step size of 1 cm gave the highest dose to the apex point. This step size was superior in terms of mean dose to optimization points. Selection of dose optimization points for the derivation of optimized dose distributions for vaginal cylinders affects the dose distributions

  5. Genetic efficiency of low-dose chronic irradiation in mammals and fish

    International Nuclear Information System (INIS)

    Goncharova, R.; Ryabokon, N.; Smolich, I.; Slukvin, A.

    2001-01-01

    -linear functions. Thus, we found genetic effects of chronic irradiation in the range of extremely low doses, from close to background and up to 10 cGy. The observed effects are not expected from high dose experiments known from scientific literature. Therefore comparative analysis of genetic efficiency of low dose chronic irradiation and higher doses of acute irradiation was carried out For this purpose linear regression models of dose-effect curves were used for micronucleated erythrocytes in bone marrow of bank voles exposed to chronically irradiation in radiocontaminated sites in natural environment (2.4 and 41.2 micro Gy/day, 0.04 and 0.68 cGy for populations) and to acute gamma-irradiation in laboratory conditions (Cs 137 sources, 5.4 R/min, 10-100 cGy). Comparison of genetic efficiency was made by three approaches: extrapolation, regression line slopes and doubling doses. When we applied extrapolation method, we found (hat the doses of acute irradiation should be much more higher, about 13.1 and 20.9 cGy, than doses of chronic irradiation (0.04 and 0.68 cGy) in order to induce the mutation frequencies, which were observed in chronically irradiated populations. As known, regression line slope or coefficient b in linear dose-effect equation means the induced mutation rate per unit dose. When we compared the regression line slopes, we revealed that the slope values for chronic exposure exceeded slopes for acute irradiation. We found also that the doubling doses of chronic low-LET exposure varied from 0.1 to approximately 2 cGy. This time the doubling doses of acute irradiation were in the range of 5 - 20 cGy. The above facts indicate higher efficiency of low dose chronic irradiation in comparison with the higher doses of acute one. Are there other data about a higher efficiency of small doses? Yes. One of them, the most important, is the data of Radiation Effect Research Foundation. They published that The Excessive Relative Risk for cancer mortality in people per Sv was the

  6. Dose assessment for Greifswald and Cadarache

    International Nuclear Information System (INIS)

    Raskob, W.

    1996-07-01

    Probabilistic dose assessments for accidental atmospheric releases of tritium and activation products as well as releases under normal operation conditions were performed for the sites of Greifswald, Germany, and Cadarache, France. Additionally, aquatic releases were considered for both sites. No country specific rules were applied and the input parameters were adapted as far as possible to those used within former ITER studies to have a better comparison to site independent dose assessments performed in the frame of ITER. The main goal was to complete the generic data base with site specific values. The agreement between the results from the ITER study on atmospheric releases and the two sites are rather good for tritium, whereas the ITER reference dose values for the activation product releases are often lower, than the maximum doses for Greifswald and Cadarache. However, the percentile values fit better to the deterministic approach of ITER. Within all scenarios, the consequences of aquatic releases are in nearly all cases smaller than those from comparable releases to the atmosphere (HTO and steel). This rule is only broken once in case of accidental releases of activated steel from Cadarache. However, the uncertainties associated with the aquatic assessments are rather high and a better data base is needed to obtain more realistic and thus more reliable dose values. (orig.) [de

  7. Higher dose intra-arterial milrinone and intra-arterial combined milrinone-nimodipine infusion as a rescue therapy for refractory cerebral vasospasm.

    Science.gov (United States)

    Duman, Enes; Karakoç, Fatma; Pinar, H Ulas; Dogan, Rafi; Fırat, Ali; Yıldırım, Erkan

    2017-12-01

    Background Cerebral vasospasm (CV) is a major cause of delayed morbidity and mortality in patients with subarachnoid hemorrhage (SAH). Various cerebral protectants have been tested in patients with aneurysmal SAH. We aimed to research the success rate of treatment of CV via intra-arterial milrinone injection and aggressive pharmacological therapy for refractory CV. Methods A total of 25 consecutive patients who received intra-arterial milrinone and nimodipine treatment for CV following SAH between 2014 and 2017 were included in the study. Patients who underwent surgical clipping were excluded. Refractory vasospasm was defined as patients with CV refractory to therapies requiring ≥3 endovascular interventions. Overall, six patients had refractory CV. Long-term neurological outcome was assessed 6-18 months after SAH using a modified Rankin score and Barthel index. Results The median modified Rankin scores were 1 (min: 0, max: 3) and Barthel index scores were 85 (min: 70, max: 100) From each vasospastic territory maximal 10-16 mg milrinone was given to patients; a maximum of 24 mg milrinone was given to each patient in a session and a maximum of 42 mg milrinone was given to a patient in a day. Both milrinone and nimodipine were given to three patients. There was a large vessel diameter increase after milrinone and nimodipine injections. No patient died due to CV; only one patient had motor dysfunction on the right lower extremity. Conclusion Higher doses of milrinone can be used effectively to control refractory CV. For exceptional patients with refractory CV, high dose intra-arterial nimodipine and milrinone infusion can be used as a rescue therapy.

  8. Endobronchial valves in severe emphysematous patients: CT evaluation of lung fissures completeness, treatment radiological response and quantitative emphysema analysis

    Energy Technology Data Exchange (ETDEWEB)

    Koenigkam-Santos, Marcel, E-mail: marcelk46@yahoo.com.br, E-mail: marcelk46@usp.b [Universidade de Sao Paulo (HCFMRP/USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas da Faculdade de Medicina; Paula, Wagner Diniz de [University of Brasilia (UnB), DF (Brazil). Brasilia University Hospital; Gompelmann, Daniela [University of Heidelberg (Germany). Department of Pneumology and Respiratory Medicine of the Chest Clinic (Thoraxklinik); Kauczor, Hans-Ulrich [University of Heidelberg (Germany). Department of Diagnostic and Interventional Radiology; Heussel, Claus Peter; Puderbach, Michael [University of Heidelberg (Germany). Department of Diagnostic and Interventional Radiology with Nuclear Medicine of the Chest Clinic (Thoraxklinik)

    2013-01-15

    Objective: To evaluate lung fissures completeness, post-treatment radiological response and quantitative CT analysis (QCTA) in a population of severe emphysematous patients submitted to endobronchial valves (EBV) implantation. Materials and Methods: Multi-detectors CT exams of 29 patients were studied, using thin-section low dose protocol without contrast. Two radiologists retrospectively reviewed all images in consensus; fissures completeness was estimated in 5% increments and post-EBV radiological response (target lobe atelectasis/volume loss) was evaluated. QCTA was performed in pre and post-treatment scans using a fully automated software. Results: CT response was present in 16/29 patients. In the negative CT response group, all 13 patients presented incomplete fissures, and mean oblique fissures completeness was 72.8%, against 88.3% in the other group. QCTA most significant results showed a reduced post-treatment total lung volume (LV) (mean 542 ml), reduced EBV-submitted LV (700 ml) and reduced emphysema volume (331.4 ml) in the positive response group, which also showed improved functional tests. Conclusion: EBV benefit is most likely in patients who have complete interlobar fissures and develop lobar atelectasis. In patients with no radiological response we observed a higher prevalence of incomplete fissures and a greater degree of incompleteness. The fully automated QCTA detected the post-treatment alterations, especially in the treated lung analysis. (author)

  9. Estimates of effective dose in adult CT examinations

    International Nuclear Information System (INIS)

    Mohamed, Mustafa Awad Elhaj.

    2015-12-01

    The goal of study was to estimate effective dose (E) in adult CT examinations for Toshiba X64 slice using CT. Exp version 2.5 software in Sudan. Using of CT in medical diagnosis delivers radiation doses to patients that are higher than those from other radiological procedures. lack of optimized protocols could be an additional source of increased dose in developing countries. In order to achieve these objectives, data of CT-scanner has been collected from three hospitals ( ANH, ZSH and MMH). Data collected included equipment information and scan parameters for individual patients, who were used to asses. 300 adult patients underwent head, chest, abdomen-pelvis and peivis CT examinations. The CT1_w , CTD1_vol, DLP, patient effective dos and organ doses were estimated, using CT exposure parameters and CT Exp version 2.5 software. A large variation of mean effective dose and organ doses among hospitals was observed for similar CT examinations. These variations largely originated from different CT scanning protocols used in different hospitals and scan length. The mean effective dose in this study in the Brain, PNS, Chest, pulmonary, Abdomen-pelvis, Pelvis, KUB and CTU were 3.2 mSv, 2.6 mSv, 18.9 mSv 17.6 mSv 27.1 mSv, 11.2 mSv, 9.6 mSv and 23.7 mSv respectively, and organ equivalent, doses presented in this study in this study for the eye lens (for head), lungs and thymus ( for chest) , liver, kidney and small intest ( for abdomen t-pelvis), bladder, uterus and gonads ( for pelvis), were 62.9 mSv, 39.5 mSv, 34.1 mSv, 53.9 mSv, 52.6 mSv, 58.1 mSv, 37 mSv, and 34.6 mSv, respectively. These values were mostly comparable to and slightly higher than the values of effective doses reported from similar studies the United Kingdom, Tanzania, Australia, Canada and Sudan. It was concluded that patient effective dose and organ doses could be substantially minimized through careful selection of scanning parameters based on clinical indications of study, patient size, and body

  10. Dose-dependent interaction between gemfibrozil and repaglinide in humans: strong inhibition of CYP2C8 with subtherapeutic gemfibrozil doses.

    Science.gov (United States)

    Honkalammi, Johanna; Niemi, Mikko; Neuvonen, Pertti J; Backman, Janne T

    2011-10-01

    Gemfibrozil 1-O-β-glucuronide inactivates CYP2C8 irreversibly. We investigated the effect of gemfibrozil dose on CYP2C8 activity in humans using repaglinide as a probe drug. In a randomized, five-phase crossover study, 10 healthy volunteers ingested 0.25 mg of repaglinide 1 h after different doses of gemfibrozil or placebo. Concentrations of plasma repaglinide, gemfibrozil, their metabolites, and blood glucose were measured. A single gemfibrozil dose of 30, 100, 300, and 900 mg increased the area under the concentration-time curve of repaglinide 1.8-, 4.5-, 6.7-, and 8.3-fold (P Gemfibrozil pharmacokinetics was characterized by a slightly more than dose-proportional increase in the area under the curve of gemfibrozil and its glucuronide. The gemfibrozil-repaglinide interaction could be mainly explained by gemfibrozil 1-O-β-glucuronide concentration-dependent, mechanism-based inhibition of CYP2C8, with a minor contribution by competitive inhibition of organic anion-transporting polypeptide 1B1 at the highest gemfibrozil dose. The findings are consistent with ∼50% inhibition of CYP2C8 already with a single 30-mg dose of gemfibrozil and >95% inhibition with 900 mg. In clinical drug-drug interaction studies, a single 900-mg dose of gemfibrozil can be used to achieve nearly complete inactivation of CYP2C8.

  11. Integral dose and evaluation of irradiated tissue volume

    International Nuclear Information System (INIS)

    Sivachenko, T.P.; Kalina, V.K.; Belous, A.K.; Gaevskij, V.I.

    1984-01-01

    Two parameters having potentialities of radiotherapy planning improvement are under consideration. One of these two parameters in an integral dose. An efficiency of application of special tables for integral dose estimation is noted. These tables were developed by the Kiev Physician Improvement Institute and the Cybernetics Institute of the Ukrainian SSR Academy of Science. The meaning of the term of ''irradiated tissue volume'' is specified, and the method of calculation of the irradiated tissue effective mass is considered. It is possible to evaluate with higher accuracy tolerance doses taking into account the irradiated mass

  12. Comparison of the two different standard flux-to-dose rate conversion factors

    International Nuclear Information System (INIS)

    Metghalchi, M.; Ashrafi, R.

    1983-01-01

    A very useful and simple way of obtaining the dose rate associated with neutron or photon fluxes is to multiply these fluxes by the appropriate flux-to-dose rate conversion factors. Two basic standard flux-to-dose rate conversion factors. are being used in all over the world, those recommended by the International Commission on Radiation Protection (ICRP) and the American National Standars (ANS). The purpose of this paper is to compare these two standard with each other. The comparison proved that the dose rate associated with a specific neutron flux, obtained by the ANS flux-to-dose rate conversion factors is usually higher than those calculated by the ICRP's conversion factors. Whereas in the case of the photon, in all energies, the difference between the dose rates obtained by these two standard flux-to-dose rate conversion factors are noticeable, and the ANS results are higher than the ICRP ones. So, it should be noted that for a specific neutron or photon flux the dose rate obtained by the ANS flux-to-dose rate conversion factors are more conservative than those obtained by the ICRP's. Therefore, in order to establish a more reasonable new standard flux-to-dose rate conversion factors, more work should be done. (author)

  13. Timely immunization completion among children in Vietnam from 2000 to 2011: a multilevel analysis of individual and contextual factors

    Directory of Open Access Journals (Sweden)

    Dao Thi Minh An

    2016-02-01

    Full Text Available Background: Since the beginning of 2014, there have been nearly 6,000 confirmed measles cases in northern Vietnam. Of these, more than 86% had neither been immunized nor was their vaccination status confirmed. Objective: To establish the likelihood that children under five in Vietnam had ‘timely immunization completion’ (2000–2011 and identify factors that account for variations in timely immunization completion. Design: Secondary data from the Multiple Indicator Cluster Survey (MICS, which sampled women aged 15–49 from the 1999 Vietnamese Population and Housing Census frame, were analyzed. Multilevel analysis using Poisson regression was undertaken. Results: Proportions of children under five who had timely immunization completion were low, especially for HBV dose 2 and HBV dose 3, which decreased between 2000 and 2011. Among seven vaccines used in the National Expanded Program of Immunization (EPI in 2000, 2006, and 2011, measles dose 1 had the highest timely immunization completion at 65.3%, 66.7%, and 73.6%, respectively, and hepatitis B dose 1 had the lowest at 17.5%, 19.3%, and 45.5%, respectively. Timely immunization completion was less common among children whose mothers had relatively less household wealth, were from ethnic minorities, lived in rural areas, and had less education. At the community level, the child's region of residence was the main predictor of timely immunization completion, and the availability of hospital delivery and community prenatal care in the local community were also determinants. Conclusion: The EPI should include ‘timely immunization completion’ as a quality indicator. There should also be greater focus and targeting in rural areas, and among women who have relatively low education, belong to minority groups, and have less household wealth. Further research on this topic using multilevel analysis is needed to better understand how these factors interact.

  14. Late biological effects of ionizing radiation as influenced by dose, dose rate, age at exposure and genetic sensitivity to neoplastic transformation

    International Nuclear Information System (INIS)

    Spalding, J.F.; Prine, J.R.; Tietjen, G.L.

    1978-01-01

    A most comprehensive investigation is in progress at the Los Alamos Scientific Laboratory to study the late biological effects of whole-body exposure to gamma irradiation as they may be influenced by total dose, dose rate, age at exposure and genetic background. Strain C57B1/6J mice of four age groups (newborn, 2, 6 and l5 months) were given five doses (20, 60, 180, 540, and 1620 rads) of gamma rays, with each dose being delivered at six dose rates (0.7, 2.1, 6.3, 18.9, 56.7 rads/day and 25 rads/min). Forty to sixty mice were used in each of the approximately 119 dose/dose-rate and age combinations. The study was done in two replications with an equal number of mice per replicaton. Strain RF/J mice were used in a companion study to investigate the influence of genetic background on the type and magnitude of effect. Results of the first and second replications of the l5-month-old age group and data on the influence of genetic background on biological response have been completed, and the results show no significant life shortening within the dose and dose-rate range used. It was also concluded that radiaton-induced neoplastic transformaton was significantly greater in mice with a known genetic sensitivity to neoplastic disease than in mammals which do not normally have a significant incidence of tumours. (author)

  15. Increasing the dose of television advertising in a national antismoking media campaign: results from a randomised field trial.

    Science.gov (United States)

    McAfee, Tim; Davis, Kevin C; Shafer, Paul; Patel, Deesha; Alexander, Robert; Bunnell, Rebecca

    2017-01-01

    While antismoking media campaigns have demonstrated effectiveness, less is known about the country-level effects of increased media dosing. The 2012 US Tips From Former Smokers (Tips) campaign generated approximately 1.6 million quit attempts overall; however, the specific dose-response from the campaign was only assessed by self-report. Assess the impact of higher ad exposure during the 2013 Tips campaign on quit-related behaviours and intentions, campaign awareness, communication about campaign, and disease knowledge. A 3-month national media buy was supplemented within 67 (of 190) randomly selected local media markets. Higher-dose markets received media buys 3 times that of standard-dose markets. We compared outcomes of interest using data collected via web-based surveys from nationally representative, address-based probability samples of 5733 cigarette smokers and 2843 non-smokers. In higher-dose markets, 87.2% of smokers and 83.9% of non-smokers recalled television campaign exposure versus 75.0% of smokers and 73.9% of non-smokers in standard-dose markets. Among smokers overall, the relative quit attempt rate was 11% higher in higher-dose markets (38.8% vs 34.9%; pmedia campaign compared standard and higher doses by randomisation of local media markets. Results demonstrate the effectiveness of a higher dose for engaging non-smokers and further increasing quit attempts among smokers, especially African-Americans. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Peripheral dose measurement for CyberKnife radiosurgery with upgraded linac shielding

    International Nuclear Information System (INIS)

    Chuang, Cynthia F.; Larson, David A.; Zytkovicz, Andrea; Smith, Vernon; Petti, Paula L.

    2008-01-01

    The authors investigated the peripheral dose reduction for CyberKnife radiosurgery treatments after the installation of a linac shielding upgrade. As in a previous investigation, the authors considered two treatment plans, one for a hypothetical target in the brain and another for a target in the thorax, delivered to an anthropomorphic phantom. The results of the prior investigation showed that the CyberKnife delivered significantly higher peripheral doses than comparable model C Gamma Knife or IMRT treatments. Current measurements, after the linac shielding upgrade, demonstrate that the additional shielding decreased the peripheral dose, expressed as a percentage of the delivered monitor units (MU), by a maximum of 59%. The dose reduction was greatest for cranial-caudal distances from the field edge less than 30 cm, and at these distances, the CyberKnife peripheral dose, expressed as a percentage of the delivered MU, is now comparable to that measured for the other treatment modalities in our previous investigation. For distances between 30 and 70 cm from the field edge, the additional shielding reduced the peripheral dose by between 20% and 55%. At these distances, the CyberKnife peripheral dose remains higher than doses measured in our previous study for the model C Gamma Knife and IMRT

  17. Cytogenetic Low-Dose Hyperradiosensitivity Is Observed in Human Peripheral Blood Lymphocytes

    Energy Technology Data Exchange (ETDEWEB)

    Seth, Isheeta [Department of Biological Sciences, Wayne State University, Detroit, Michigan (United States); Joiner, Michael C. [Department of Radiation Oncology, Wayne State University, Detroit, Michigan (United States); Tucker, James D., E-mail: jtucker@biology.biosci.wayne.edu [Department of Biological Sciences, Wayne State University, Detroit, Michigan (United States)

    2015-01-01

    Purpose: The shape of the ionizing radiation response curve at very low doses has been the subject of considerable debate. Linear-no-threshold (LNT) models are widely used to estimate risks associated with low-dose exposures. However, the low-dose hyperradiosensitivity (HRS) phenomenon, in which cells are especially sensitive at low doses but then show increased radioresistance at higher doses, provides evidence of nonlinearity in the low-dose region. HRS is more prominent in the G2 phase of the cell cycle than in the G0/G1 or S phases. Here we provide the first cytogenetic mechanistic evidence of low-dose HRS in human peripheral blood lymphocytes using structural chromosomal aberrations. Methods and Materials: Human peripheral blood lymphocytes from 2 normal healthy female donors were acutely exposed to cobalt 60 γ rays in either G0 or G2 using closely spaced doses ranging from 0 to 1.5 Gy. Structural chromosomal aberrations were enumerated, and the slopes of the regression lines at low doses (0-0.4 Gy) were compared with doses of 0.5 Gy and above. Results: HRS was clearly evident in both donors for cells irradiated in G2. No HRS was observed in cells irradiated in G0. The radiation effect per unit dose was 2.5- to 3.5-fold higher for doses ≤0.4 Gy than for doses >0.5 Gy. Conclusions: These data provide the first cytogenetic evidence for the existence of HRS in human cells irradiated in G2 and suggest that LNT models may not always be optimal for making radiation risk assessments at low doses.

  18. Combination of High-Dose Methylprednisolone and Defibrotide for Veno-Occlusive Disease in Pediatric Hematopoietic Stem Cell Transplant Recipients.

    Science.gov (United States)

    Gloude, Nicholas J; Jodele, Sonata; Teusink-Cross, Ashley; Grimley, Michael; Davies, Stella M; Lane, Adam; Myers, Kasiani C

    2018-01-01

    Veno-occlusive disease (VOD) is a serious complication of hematopoietic stem cell transplant (HSCT), with high mortality in severe cases and until recently very limited therapeutic options consisting largely of supportive care. Defibrotide was recently approved in the United States for the treatment of severe VOD in patients with renal or pulmonary dysfunction after HSCT. Our group previously published on the use of high-dose methylprednisolone (500 mg/m 2 per dose every 12 hours for 6 doses) in patients with VOD, showing good success. A small subset of these individuals were also treated with defibrotide, but additional studies using the combination of high-dose methylprednisolone and defibrotide for the treatment of VOD are lacking. We present a single-institution retrospective chart review of 15 HSCT patients with VOD treated with the combination of high-dose methylprednisolone and defibrotide. VOD developed at a median of 17 days post-HSCT, and combination therapy was initiated within 1 day of VOD diagnosis. Twelve of 15 patients (80%) had multiorgan failure. Our single-center experience using both high-dose methylprednisolone and defibrotide showed a day +100 survival rate of 73% and an overall VOD complete resolution rate of 66.7%, higher than the rates reported in the recent literature using defibrotide alone (40% to 50% day +100 overall survival). These data suggest that the combination of high-dose steroids and defibrotide may be superior to defibrotide alone and warrant further investigation. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  19. Reappraisal of the reference dose distribution in the UNSCEAR 1977 report

    International Nuclear Information System (INIS)

    Kumazawa, Shigeru

    2008-01-01

    This paper provides the update of the reference dose distribution proposed by G.A.M. Web and D. Beninson in Annex E to the UNSCEAR 1977 Report. To demonstrate compliance with regulatory obligations regarding doses to individuals, they defined it with the following properties: 1) The distribution of annual doses is log-normal; 2) The mean of the annual dose distribution is 5 m Gy (10% of the ICRP 1977 dose limit); 3) The proportion of workers exceeding 50 m Gy is 0.1%. The concept of the reference dose distribution is still important to understand the inherent variation of individual doses to workers controlled by source-related and individual-related efforts of best dose reduction. In the commercial nuclear power plant, the dose distribution becomes the more apart from the log-normal due to the stronger ALARA efforts and the revised dose limits. The monitored workers show about 1 m Sv of annual mean and far less than 0.1% of workers above 20 m Sv. The updated models of dose distribution consist of log-normal (no feedback on dose X) ln(X)∼N(μ,σ 2 ), hybrid log-normal (feedback on higher X by ρ) hyb(ρX)=ρX+ln(ρX)∼N(μ,σ 2 ), hybrid S B (feedback on higher dose quotient X/(D-X) not close to D by ρ) hyb[ρX/(D.X)]∼N(μ,σ 2 ) and Johnson's S B (limit to D) ln[X/(D-X)]∼N(μ,σ 2 ). These models afford interpreting the degree of dose control including dose constraint/limit to the reference distribution. Some of distributions are examined to characterize the variation of doses to members of the public with uncertainty. (author)

  20. Clinical value of CARE dose 4D technique in decreasing CT scanning dose of adult chest

    International Nuclear Information System (INIS)

    Wu Aiqin; Zheng Wenlong; Xu Chongyong; Fang Bidong; Ge Wen

    2011-01-01

    Objective: To investigate the value of CARE Dose 4D technique in decreasing radiation dose and improving image quality of multi-slice spiral CT in adult chest scanning. Methods: 100 patients of chest CT scanning were equally divided into study group and control group randomly. CARE Dose 4D Technique was used in study group. Effective mAs value, volume CT dose index (CTDI vol ) and dose length product (DLP) were displayed automatically in machine while chest scanning; those values and actual mAs value of every image were recorded respectively. The image quality at apex of lung, lower edge of aorta arch, middle area of left atrium and base of lung on every image of 400 images was judged and classified as three level (excellent, good, poor) by two deputy chief physicians with double blind method, the image noise at corresponding parts was measured. Results: While setting 80 mAs for quality reference mAs, the effective mAs value in study group most decreased 44 mAs than control group with an average decrease of 9.60 (12.0%), CTDI vol with 4.75 mGy with an average decrease of 0.95 mCy (11.0%), DLP 99.50% in study group, with 98.0% in control group. But it was higher at apex of lung and base of lung, lower at middle area of left atrium, and similar at lower edge of aorta arch in study group than contrast group. The image noise were lower at apex of lung and base of lung in study group than control group (t =6.299 and 2.332, all P<0.05), higher at middle area of left atrium in study group than control group (t=3.078, P<0.05) and similar at lower edge of aorta arch in study group than control group (t=1.191, P>0.05). Conclusions: CARE Dose 4D technique provides a function regulated mAs real-time on line, it not only raises utilization rate of radiation and decreases radiation dose, but also promises and increases image quality in chest CT scanning, and has some clinical significance. (authors)

  1. Evaluation of occupational and patient radiation doses in orthopedic surgery

    International Nuclear Information System (INIS)

    Sulieman, A.; Alzimami, K.; Habeeballa, B.; Osman, H.; Abdelaziz, I.; Sassi, S.A.; Sam, A.K.

    2015-01-01

    This study intends to measure the radiation dose to patients and staff during (i) Dynamic Hip Screw (DHS) and (ii) Dynamic Cannula Screw (DCS) and to evaluate entrance surface Air kerma (ESAK) dose and organ doses and effective doses. Calibrated Thermoluminescence dosimeters (TLD-GR200A) were used. The mean patients’ doses were 0.46 mGy and 0.07 mGy for DHS and DCS procedures, respectively. The mean staff doses at the thyroid and chest were 4.69 mGy and 1.21 mGy per procedure. The mean organ and effective dose for patients and staff were higher in DHS compared to DCS. Orthopedic surgeons were exposed to unnecessary radiation doses due to the lack of protection measures. The radiation dose per hip procedure is within the safety limit and less than the previous studies

  2. A study of different dose calculation methods and the impact on the dose evaluation protocol in lung stereotactic radiation therapy

    International Nuclear Information System (INIS)

    Takada, Takahiro; Furuya, Tomohisa; Ozawa, Shuichi; Ito, Kana; Kurokawa, Chie; Karasawa, Kumiko; Miura, Kohei

    2008-01-01

    AAA (analytical anisotropic algorithm) dose calculation, which shows a better performance for heterogeneity correction, was tested for lung stereotactic radiation therapy (SBRT) in comparison to conventional PBC (pencil beam convolution method) to evaluate its impact on tumor dose parameters. Eleven lung SBRT patients who were treated with photon 4 MV beams in our department between April 2003 and February 2007 were reviewed. Clinical target volume (CTV) was delineated including the spicula region on planning CT images. Planning target volume (PTV) was defined by adding the internal target volume (ITV) and set-up margin (SM) of 5 mm from CTV, and then an multileaf collimator (MLC) penumbra margin of another 5 mm was also added. Six-port non-coplanar beams were employed, and a total prescribed dose of 48 Gy was defined at the isocenter point with four fractions. The entire treatment for an individual patient was completed within 8 days. Under the same prescribed dose, calculated dose distribution, dose volume histogram (DVH), and tumor dose parameters were compared between two dose calculation methods. In addition, the fractionated prescription dose was repeatedly scaled until the monitor units (MUs) calculated by AAA reached a level of MUs nearly identical to those achieved by PBC. AAA resulted in significantly less D95 (irradiation dose that included 95% volume of PTV) and minimal dose in PTV compared to PBC. After rescaling of each MU for each beam in the AAA plan, there was no revision of the isocenter of the prescribed dose required. However, when the PTV volume was less than 20 cc, a 4% lower prescription resulted in nearly identical MUs between AAA and PBC. The prescribed dose in AAA should be the same as that in PBC, if the dose is administered at the isocenter point. However, planners should compare DVHs and dose distributions between AAA and PBC for a small lung tumor with a PTV volume less than approximately 20 cc. (author)

  3. Dose painting by contours versus dose painting by numbers for stage II/III lung cancer: Practical implications of using a broad or sharp brush

    International Nuclear Information System (INIS)

    Meijer, Gert; Steenhuijsen, Jacco; Bal, Matthieu; De Jaeger, Katrien; Schuring, Danny; Theuws, Jacqueline

    2011-01-01

    Purpose: Local recurrence rates are high in patients with locally advanced NSCLC treated with 60 to 66 Gy in 2 Gy fractions. It is hypothesised that boosting volumes with high SUV on the pre-treatment FDG-PET scan potentially increases local control while maintaining acceptable toxicity levels. We compared two approaches: threshold-based dose painting by contours (DPBC) with voxel-based dose painting by numbers (DPBN). Materials and methods: Two dose painted plans were generated for 10 stage II/III NSCLC patients with 66 Gy at 2-Gy fractions to the entire PTV and a boost dose to the high SUV areas within the primary GTV. DPBC aims for a uniform boost dose at the volume encompassing the SUV 50%-region (GTV boost ). DPBN aims for a linear relationship between the boost dose to a voxel and the underlying SUV. For both approaches the boost dose was escalated up to 130 Gy (in 33 fractions) or until the dose limiting constraint of an organ at risk was met. Results: For three patients (with relatively small peripheral tumours) the dose within the GTV could be boosted to 130 Gy using both strategies. For the remaining patients the boost dose was confined by a critical structure (mediastinal structures in six patients, lungs in one patient). In general the amount of large brush DPBC boosting is limited whenever the GTV boost is close to any serial risk organ. In contrast, small brush DPBN inherently boosts at a voxel-by-voxel basis allowing significant higher dose values to high SUV voxels more distant from the organs at risk. We found that the biological SUV gradients are reasonably congruent with the dose gradients that standard linear accelerators can deliver. Conclusions: Both large brush DPBC and sharp brush DPBN techniques can be used to considerably boost the dose to the FDG avid regions. However, significantly higher boost levels can be obtained using sharp brush DPBN although sometimes at the cost of a less increased dose to the low SUV regions.

  4. Patient dose assessment in different diagnostic procedures in nuclear medicine

    International Nuclear Information System (INIS)

    Sena, E. de; Bejar, M.J.; Berenguer, R.; Ruano, R.; Tamayo, P.

    2001-01-01

    Effective doses have been estimated for 314 patients under diagnostic procedures in a Nuclear Medicine Department using data reported in ICRP-80 and RIDIC (Radiation Internal Dose Information Center). Data on administered activity, radiopharmaceutical and administration route, age and sex of the patients have been collected. Doses in the most exposed critical organ for every protocol, doses in uterus, doses in fetus versus the stage of pregnancy (in case the female patient was pregnant) and doses for nursing infants have been also estimated. Ga-67 studies give the highest effective doses per protocol followed by cardiac SPECT procedures using Tl-201 chloride. Ga-67 studies also give the highest absorbed doses in uterus. Due to not administering different activities, depending on height and weight of adults, women receive doses about 20% higher than men. This would be a practice to modify in the future in order to optimise doses. (author)

  5. Patient dose assessment in different diagnostic procedures in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Sena, E de; Bejar, M J; Berenguer, R [Servicio de Radiofisica y Proteccion Radiologica, Salamanca (Spain); Ruano, R; Tamayo, P [Servicio de Medicina Nuclear, Hospital Universitario de Salamanca (Spain)

    2001-03-01

    Effective doses have been estimated for 314 patients under diagnostic procedures in a Nuclear Medicine Department using data reported in ICRP-80 and RIDIC (Radiation Internal Dose Information Center). Data on administered activity, radiopharmaceutical and administration route, age and sex of the patients have been collected. Doses in the most exposed critical organ for every protocol, doses in uterus, doses in fetus versus the stage of pregnancy (in case the female patient was pregnant) and doses for nursing infants have been also estimated. Ga-67 studies give the highest effective doses per protocol followed by cardiac SPECT procedures using Tl-201 chloride. Ga-67 studies also give the highest absorbed doses in uterus. Due to not administering different activities, depending on height and weight of adults, women receive doses about 20% higher than men. This would be a practice to modify in the future in order to optimise doses. (author)

  6. Radiation doses from computed tomography in Australia

    International Nuclear Information System (INIS)

    Thomson, J.E.M.; Tingey, D.R.C.

    1997-11-01

    Recent surveys in various countries have shown that computed tomography (CT) is a significant and growing contributor to the radiation dose from diagnostic radiology. Australia, with 332 CT scanners (18 per million people), is well endowed with CT equipment compared to European countries (6 to 13 per million people). Only Japan, with 8500 units (78 per million people), has a significantly higher proportion of CT scanners. In view of this, a survey of CT facilities, frequency of examinations, techniques and patient doses has been performed in Australia. It is estimated that there are 1 million CT examinations in Australia each year, resulting in a collective effective dose of 7000 Sv and a per caput dose of 0.39 mSv. This per caput dose is much larger than found in earlier studies in the UK and New Zealand but is less than 0.48 mSv in Japan. Using the ICRP risk factors, radiation doses from CT could be inducing about 280 fatal cancers per year in Australia. CT is therefore a significant, if not the major, single contributor to radiation doses and possible risk from diagnostic radiology. (authors)

  7. Dose rate effects of low-LET ionizing radiation on fish cells

    Energy Technology Data Exchange (ETDEWEB)

    Vo, Nguyen T.K. [McMaster University, Radiation Sciences Program, School of Graduate and Postdoctoral Studies, Hamilton, ON (Canada); Seymour, Colin B.; Mothersill, Carmel E. [McMaster University, Radiation Sciences Program, School of Graduate and Postdoctoral Studies, Hamilton, ON (Canada); McMaster University, Department of Biology, Hamilton, ON (Canada)

    2017-11-15

    Radiobiological responses of a highly clonogenic fish cell line, eelB, to low-LET ionizing radiation and effects of dose rates were studied. In acute exposure to 0.1-12 Gy of gamma rays, eelB's cell survival curve displayed a linear-quadratic (LQ) relationship. In the LQ model, α, β, and α/β ratio were 0.0024, 0.037, and 0.065, respectively; for the first time that these values were reported for fish cells. In the multi-target model, n, D{sub o}, and D{sub q} values were determined to be 4.42, 2.16, and 3.21 Gy, respectively, and were the smallest among fish cell lines being examined to date. The mitochondrial potential response to gamma radiation in eelB cells was at least biphasic: mitochondria hyperpolarized 2 h and then depolarized 5 h post-irradiation. Upon receiving gamma rays with a total dose of 5 Gy, dose rates (ranging between 83 and 1366 mGy/min) had different effects on the clonogenic survival but not the mitochondrial potential. The clonogenic survival was significantly higher at the lowest dose rate of 83 mGy/min than at the other higher dose rates. Upon continuous irradiation with beta particles from tritium at 0.5, 5, 50, and 500 mGy/day for 7 days, mitochondria significantly depolarized at the three higher dose rates. Clearly, dose rates had differential effects on the clonogenic survival of and mitochondrial membrane potential in fish cells. (orig.)

  8. An Hourly Dose-Escalation Desensitization Protocol for Aspirin-Exacerbated Respiratory Disease.

    Science.gov (United States)

    Chen, Justin R; Buchmiller, Brett L; Khan, David A

    2015-01-01

    Aspirin desensitization followed by maintenance therapy effectively improves symptom control in patients with aspirin exacerbated respiratory disease (AERD). The majority of current desensitization protocols use 3-hour dosing intervals and often require 2 to 3 days to complete. We evaluated hourly dose escalations in a subset of patients with chronic rhinosinusitis, nasal polyps, and asthma who historically reacted to aspirin within 1 hour or were avoiding aspirin with the goal of developing a safe and efficient desensitization protocol. Fifty-seven aspirin desensitizations were performed under the hourly protocol. All patients had refractory nasal polyposis as an indication for aspirin desensitization. The clinical characteristics of each subject were analyzed in relation to aspects of his or her reactions during the procedure. Ninety-eight percent of study patients were successfully treated under the hourly protocol, including those with a history of severe reactions and intubation. None required further medication than is available in an outpatient allergy clinic. A total of 96% of reactors recorded a bronchial or naso-ocular reaction within 1 hour of the preceding dose. Of the total patients on this protocol, 40% were able to complete the procedure in a single day, and 60% within 2 days. Patients with AERD who have a history of symptoms less than 1 hour after aspirin exposure can be safely desensitized with a 1-hour dose-escalation protocol that can often be completed in a single day. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  9. Hardness, function, emotional well-being, satisfaction and the overall sexual experience in men using 100-mg fixed-dose or flexible-dose sildenafil citrate.

    Science.gov (United States)

    Ströberg, P; Kaminetsky, J C; Park, N C; Goldfischer, E R; Creanga, D L; Stecher, V J

    2010-01-01

    The prescribing information for sildenafil citrate (VIAGRA, Pfizer, New York, NY, USA) recommends flexible dosing (50 mg initially, adjusted to 100 or 25 mg based on effectiveness and tolerability) in most men with erectile dysfunction (ED). In many men, however, 100 mg may be the most appropriate initial dose because it would reduce the need for titration and could prevent discouragement and treatment abandonment should 50 mg be insufficient. Results of two previously published double-blind, placebo-controlled sildenafil trials of similar design except for a fixed-dose vs flexible-dose regimen were analyzed. Relative to the flexible-dose, approximately one-third more men were satisfied with an initial and fixed dose of 100 mg. In addition, tolerability was similar, and improvements from baseline in outcomes on validated, ED-specific, patient-reported questionnaires were either similar (erectile function and the percentage of completely hard and fully rigid erections) or greater (emotional well-being and the overall sexual experience). The similarity in outcomes is not surprising given that almost 90% of the men in the flexible-dose trial titrated to 100 mg after 2 weeks. These data suggest prescription of an initial dose of 100 mg for men with ED, except in those for whom it is inappropriate.

  10. Doses to nurses by the technetium-99m, in private and public sector

    International Nuclear Information System (INIS)

    Bied, J.Ch.; Philippon, B.

    1999-01-01

    The global body dose due to the technetium is 1.2 and 1.9 mSv for the two nurses of the private sector. In the public sector, the level reached by the personnel is 0.75 mSv for the global body dose, and the only technetium (global body dose 1.4 and 2.1 mSv for the private sector, 0.95 for the public sector and for the whole of radiations measured by the O.P.R.I. film dosemeter. The doses received at the fingers level present higher levels in the private sector. But these values, 15.2 and 10.7 mSv by month, that is to say 180 mSv by year are the 2/5 of the maximum permissible value. The two persons of the private sector received whole body doses, higher that the doses of the public sector. These doses are about 1.2 to 1.9 these ones received in the public sector. (N.C.)

  11. Ambient neutron dose equivalent outside concrete vault rooms for 15 and 18 MV radiotherapy accelerators

    International Nuclear Information System (INIS)

    Martinez-ovalle, S. A.; Barquero, R.; Gomez-ros, J. M.; Lallena, A. M.

    2012-01-01

    In this work, the ambient dose equivalent, H*(10), due to neutrons outside three bunkers that house a 15- and a 18-MV Varian Clinac 2100C/D and a 15-MV Elekta Inor clinical linacs, has been calculated. The Monte Carlo code MCNPX (v. 2.5) has been used to simulate the neutron production and transport. The complete geometries including linacs and full installations have been built up according to the specifications of the manufacturers and the planes provided by the corresponding medical physical services of the hospitals where the three linacs operate. Two of these installations, those lodging the Varian linacs, have an entrance door to the bunker while the other one does not, although it has a maze with two bends. Various treatment orientations were simulated in order to establish plausible annual equivalent doses. Specifically anterior-posterior, posterior-anterior, left lateral, right lateral orientations and an additional one with the gantry rotated 30 deg. have been studied. Significant dose rates have been found only behind the walls and the door of the bunker, near the entrance and the console, with a maximum of 12 μSv h -1 . Dose rates per year have been calculated assuming a conservative workload for the three facilities. The higher dose rates in the corresponding control areas were 799 μSv y -1 , in the case of the facility which operates the 15-MV Clinac, 159 μSv y -1 , for that with the 15-MV Elekta, and 21 μSv y -1 for the facility housing the 18-MV Varian. A comparison with measurements performed in similar installations has been carried out and a reasonable agreement has been found. The results obtained indicate that the neutron contamination does not increase the doses above the legal limits and does not produce a significant enhancement of the dose equivalent calculated. When doses are below the detection limits provided by the measuring devices available today, MCNPX simulation provides an useful method to evaluate neutron dose equivalents

  12. Radioactivities (dose rates) of rocks in Japan

    International Nuclear Information System (INIS)

    Matsuda, Hideharu; Minato, Susumu

    1995-01-01

    The radioactive distribution (radiation doses) of major rocks in Japan was monitored to clarify the factors influencing terrestrial gamma-ray absorbed dose rates. The rock samples were reduced to powder and analyzed by well-type NaI(Tl) scintillation detector and pulse height analyzer. Terrestrial gamma-ray dose rates were estimated in terms of gamma radiation dose rate 1 m above the ground. The radioactivity concentration was highest in acidic rock which contains much SiO 2 among igneous rock, followed by neutral rock, basic rock, and ultrabasic rock. The radioactive concentration was 30-40% lower in acidic and clastic rocks than those of the world average concentration. Higher radioactive concentration was observed in soils than the parent rocks of sedimentary rock and metamorphic rock. The gamma radiation dose rate was in proportion to the radioactive concentration of the rocks. To clarify the radioactive effect in the change course of rocks into soils, comparative measurement of outcrop and soil radioactive concentrations is important. (S.Y.)

  13. Online 3D EPID-based dose verification: Proof of concept

    Energy Technology Data Exchange (ETDEWEB)

    Spreeuw, Hanno; Rozendaal, Roel, E-mail: r.rozendaal@nki.nl; Olaciregui-Ruiz, Igor; González, Patrick; Mans, Anton; Mijnheer, Ben [Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam 1066 CX (Netherlands); Herk, Marcel van [University of Manchester, Manchester Academic Health Science Centre, The Christie NHS Foundation Trust, Manchester M20 4BX (United Kingdom)

    2016-07-15

    Purpose: Delivery errors during radiotherapy may lead to medical harm and reduced life expectancy for patients. Such serious incidents can be avoided by performing dose verification online, i.e., while the patient is being irradiated, creating the possibility of halting the linac in case of a large overdosage or underdosage. The offline EPID-based 3D in vivo dosimetry system clinically employed at our institute is in principle suited for online treatment verification, provided the system is able to complete 3D dose reconstruction and verification within 420 ms, the present acquisition time of a single EPID frame. It is the aim of this study to show that our EPID-based dosimetry system can be made fast enough to achieve online 3D in vivo dose verification. Methods: The current dose verification system was sped up in two ways. First, a new software package was developed to perform all computations that are not dependent on portal image acquisition separately, thus removing the need for doing these calculations in real time. Second, the 3D dose reconstruction algorithm was sped up via a new, multithreaded implementation. Dose verification was implemented by comparing planned with reconstructed 3D dose distributions delivered to two regions in a patient: the target volume and the nontarget volume receiving at least 10 cGy. In both volumes, the mean dose is compared, while in the nontarget volume, the near-maximum dose (D2) is compared as well. The real-time dosimetry system was tested by irradiating an anthropomorphic phantom with three VMAT plans: a 6 MV head-and-neck treatment plan, a 10 MV rectum treatment plan, and a 10 MV prostate treatment plan. In all plans, two types of serious delivery errors were introduced. The functionality of automatically halting the linac was also implemented and tested. Results: The precomputation time per treatment was ∼180 s/treatment arc, depending on gantry angle resolution. The complete processing of a single portal frame

  14. Online 3D EPID-based dose verification: Proof of concept

    International Nuclear Information System (INIS)

    Spreeuw, Hanno; Rozendaal, Roel; Olaciregui-Ruiz, Igor; González, Patrick; Mans, Anton; Mijnheer, Ben; Herk, Marcel van

    2016-01-01

    Purpose: Delivery errors during radiotherapy may lead to medical harm and reduced life expectancy for patients. Such serious incidents can be avoided by performing dose verification online, i.e., while the patient is being irradiated, creating the possibility of halting the linac in case of a large overdosage or underdosage. The offline EPID-based 3D in vivo dosimetry system clinically employed at our institute is in principle suited for online treatment verification, provided the system is able to complete 3D dose reconstruction and verification within 420 ms, the present acquisition time of a single EPID frame. It is the aim of this study to show that our EPID-based dosimetry system can be made fast enough to achieve online 3D in vivo dose verification. Methods: The current dose verification system was sped up in two ways. First, a new software package was developed to perform all computations that are not dependent on portal image acquisition separately, thus removing the need for doing these calculations in real time. Second, the 3D dose reconstruction algorithm was sped up via a new, multithreaded implementation. Dose verification was implemented by comparing planned with reconstructed 3D dose distributions delivered to two regions in a patient: the target volume and the nontarget volume receiving at least 10 cGy. In both volumes, the mean dose is compared, while in the nontarget volume, the near-maximum dose (D2) is compared as well. The real-time dosimetry system was tested by irradiating an anthropomorphic phantom with three VMAT plans: a 6 MV head-and-neck treatment plan, a 10 MV rectum treatment plan, and a 10 MV prostate treatment plan. In all plans, two types of serious delivery errors were introduced. The functionality of automatically halting the linac was also implemented and tested. Results: The precomputation time per treatment was ∼180 s/treatment arc, depending on gantry angle resolution. The complete processing of a single portal frame

  15. Online 3D EPID-based dose verification: Proof of concept.

    Science.gov (United States)

    Spreeuw, Hanno; Rozendaal, Roel; Olaciregui-Ruiz, Igor; González, Patrick; Mans, Anton; Mijnheer, Ben; van Herk, Marcel

    2016-07-01

    Delivery errors during radiotherapy may lead to medical harm and reduced life expectancy for patients. Such serious incidents can be avoided by performing dose verification online, i.e., while the patient is being irradiated, creating the possibility of halting the linac in case of a large overdosage or underdosage. The offline EPID-based 3D in vivo dosimetry system clinically employed at our institute is in principle suited for online treatment verification, provided the system is able to complete 3D dose reconstruction and verification within 420 ms, the present acquisition time of a single EPID frame. It is the aim of this study to show that our EPID-based dosimetry system can be made fast enough to achieve online 3D in vivo dose verification. The current dose verification system was sped up in two ways. First, a new software package was developed to perform all computations that are not dependent on portal image acquisition separately, thus removing the need for doing these calculations in real time. Second, the 3D dose reconstruction algorithm was sped up via a new, multithreaded implementation. Dose verification was implemented by comparing planned with reconstructed 3D dose distributions delivered to two regions in a patient: the target volume and the nontarget volume receiving at least 10 cGy. In both volumes, the mean dose is compared, while in the nontarget volume, the near-maximum dose (D2) is compared as well. The real-time dosimetry system was tested by irradiating an anthropomorphic phantom with three VMAT plans: a 6 MV head-and-neck treatment plan, a 10 MV rectum treatment plan, and a 10 MV prostate treatment plan. In all plans, two types of serious delivery errors were introduced. The functionality of automatically halting the linac was also implemented and tested. The precomputation time per treatment was ∼180 s/treatment arc, depending on gantry angle resolution. The complete processing of a single portal frame, including dose verification, took

  16. Size-specific dose estimate (SSDE) provides a simple method to calculate organ dose for pediatric CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Bria M.; Brady, Samuel L., E-mail: samuel.brady@stjude.org; Kaufman, Robert A. [Department of Radiological Sciences, St Jude Children' s Research Hospital, Memphis, Tennessee 38105 (United States); Mirro, Amy E. [Department of Biomedical Engineering, Washington University, St Louis, Missouri 63130 (United States)

    2014-07-15

    previously published pediatric patient doses that accounted for patient size in their dose calculation, and was found to agree in the chest to better than an average of 5% (27.6/26.2) and in the abdominopelvic region to better than 2% (73.4/75.0). Conclusions: For organs fully covered within the scan volume, the average correlation of SSDE and organ absolute dose was found to be better than ±10%. In addition, this study provides a complete list of organ dose correlation factors (CF{sub SSDE}{sup organ}) for the chest and abdominopelvic regions, and describes a simple methodology to estimate individual pediatric patient organ dose based on patient SSDE.

  17. Effective doses to family members of patients treated with radioiodine-131

    International Nuclear Information System (INIS)

    Kocovska, M Zdraveska; Vaskova, O; Majstorov, V; Kuzmanovska, S; Gjorceva, D Pop; Jokic, V Spasic

    2011-01-01

    The purpose of this study was to evaluate the effective dose to family members of thyroid cancer and hyperthyroid patients treated with radioiodine-131, and also to compare the results with dose constraints proposed by the International Commission of Radiological Protection (ICRP) and the Basic Safety Standards (BSS) of the International Atomic Energy Agency (IAEA). For the estimation of the effective doses, sixty family members of sixty patients, treated with radioiodine-131, and thermoluminiscent dosimeters (Model TLD 100) were used. Thyroid cancer patients were hospitalized for three days, while hyperthyroid patients were treated on out-patient basis. The family members wore TLD in front of the torso for seven days. The radiation doses to family members of thyroid cancer patients were well below the recommended dose constraint of 1 mSv. The mean value of effective dose was 0.21 mSv (min 0.02 - max 0.51 mSv). Effective doses, higher than 1 mSv, were detected for 11 family members of hyperthyroid patients. The mean value of effective dose of family members of hyperthyroid patients was 0.87 mSv (min 0.12 - max 6.79). The estimated effective doses to family members of hyperthyroid patients were higher than the effective doses to family members of thyroid carcinoma patients. These findings may be considered when establishing new national guidelines concerning radiation protection and release of patients after a treatment with radioiodine therapy.

  18. Uncertainty and power at low levels of incurred radiation dose

    International Nuclear Information System (INIS)

    Wilson, M; Jackson, D

    2005-01-01

    It is common practice when calculating dose to exposed populations to average the variables that go into the dose calculation (e.g. environmental concentrations, air kerma, consumption rates, occupancy rates). This approach is simple and can be useful where data are obtained over different periods (weekly, monthly, quarterly), where samples may be bulked for some analyses but not others and where gaps in the data are present. However, such an approach does not yield information on the degree of uncertainty around the average dose calculated. An alternative approach is to estimate the dose to each individual and to obtain an average from this data set, which can then also be used to derive a measure of uncertainty around the central dose estimate. In this study, we demonstrate the variability in dose estimates using a hypothetical data set and consider the implications for sample size to achieve fixed confidence or resolving power. We recommend calculating the dose to every individual sampled, in order both to obtain the average dose and to estimate its variability. We argue that it is best practice to obtain information as complete as possible from the available sample of individuals

  19. Low dose rate and high dose rate intracavitary treatment for cervical cancer

    International Nuclear Information System (INIS)

    Hareyama, Masato; Oouchi, Atsushi; Shidou, Mitsuo

    1997-01-01

    From 1984 through 1993, 144 previous untreated patients with carcinoma of uterine cervix were treated with either low dose rate 137 Cs therapy (LDR) or high dose rate 60 Co therapy (HDR). The local failure rates for more than 2-years for the primary lesions were 11.8% (8 of 63 patients) for LDR and 18.0% (11 of 61 patients). Rectal complication rates were significantly lower for HDR versus LDR (14.3% VS. 32.8%. p<0.01). Also, bladder complication rates were significantly lower for HDR versus LDR (0% VS. 10.4%, p<0.005). Treatment results in term of local control were equivalent for HDR and LDR treatment. However, the incidence of complications was higher for the LDR group than for the HDR group. (author)

  20. Algorithm for assessment of mean annual gonad dose and genetically significant dose from the data of personal dosimetry

    International Nuclear Information System (INIS)

    Tomasevic, M.; Radovanovic, R.

    1986-01-01

    During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author)

  1. Low dose ionizing radiation exposure and cardiovascular disease mortality: cohort study based on Canadian national dose registry of radiation workers

    International Nuclear Information System (INIS)

    Zielinski, J. M.; Band, P. R.; Ashmore, P. J.; Jiang, H.; Shilnikova, N. S.; Tait, V. K.; Krewski, D.

    2009-01-01

    The purpose of our study was to assess the risk of cardiovascular disease (CVD) mortality in a Canadian cohort of 337 397 individuals (169 256 men and 168 141 women) occupationally exposed to ionizing radiation and included in the National Dose Registry (NDR) of Canada. Material and Methods: Exposure to high doses of ionizing radiation, such as those received during radiotherapy, leads to increased risk of cardiovascular diseases. The emerging evidence of excess risk of CVDs after exposure to doses well below those previously considered as safe warrants epidemiological studies of populations exposed to low levels of ionizing radiation. In the present study, the cohort consisted of employees at nuclear power stations (nuclear workers) as well as medical, dental and industrial workers. The mean whole body radiation dose was 8.6 mSv for men and 1.2 mSv for women. Results: During the study period (1951 - 1995), as many as 3 533 deaths from cardiovascular diseases have been identified (3 018 among men and 515 among women). In the cohort, CVD mortality was significantly lower than in the general population of Canada. The cohort showed a significant dose response both among men and women. Risk estimates of CVD mortality in the NDR cohort, when expressed as excess relative risk per unit dose, were higher than those in most other occupational cohorts and higher than in the studies of Japanese atomic bomb survivors. Conclusions: The study has demonstrated a strong positive association between radiation dose and the risk of CVD mortality. Caution needs to be exercised when interpreting these results, due to the potential bias introduced by dosimetry uncertainties, the possible record linkage errors, and especially by the lack of adjustment for non-radiation risk factors. (authors)

  2. Maxine: A spreadsheet for estimating dose from chronic atmospheric radioactive releases

    Energy Technology Data Exchange (ETDEWEB)

    Jannik, Tim [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Bell, Evaleigh [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Dixon, Kenneth [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-07-24

    MAXINE is an EXCEL© spreadsheet, which is used to estimate dose to individuals for routine and accidental atmospheric releases of radioactive materials. MAXINE does not contain an atmospheric dispersion model, but rather doses are estimated using air and ground concentrations as input. Minimal input is required to run the program and site specific parameters are used when possible. Complete code description, verification of models, and user’s manual have been included.

  3. Non-linear dose-response of aluminium hydroxide adjuvant particles: Selective low dose neurotoxicity

    International Nuclear Information System (INIS)

    Crépeaux, Guillemette; Eidi, Housam; David, Marie-Odile; Baba-Amer, Yasmine; Tzavara, Eleni; Giros, Bruno; Authier, François-Jérôme; Exley, Christopher; Shaw, Christopher A.; Cadusseau, Josette

    2017-01-01

    Aluminium (Al) oxyhydroxide (Alhydrogel ® ), the main adjuvant licensed for human and animal vaccines, consists of primary nanoparticles that spontaneously agglomerate. Concerns about its safety emerged following recognition of its unexpectedly long-lasting biopersistence within immune cells in some individuals, and reports of chronic fatigue syndrome, cognitive dysfunction, myalgia, dysautonomia and autoimmune/inflammatory features temporally linked to multiple Al-containing vaccine administrations. Mouse experiments have documented its capture and slow transportation by monocyte-lineage cells from the injected muscle to lymphoid organs and eventually the brain. The present study aimed at evaluating mouse brain function and Al concentration 180 days after injection of various doses of Alhydrogel ® (200, 400 and 800 μg Al/kg of body weight) in the tibialis anterior muscle in adult female CD1 mice. Cognitive and motor performances were assessed by 8 validated tests, microglial activation by Iba-1 immunohistochemistry, and Al level by graphite furnace atomic absorption spectroscopy. An unusual neuro-toxicological pattern limited to a low dose of Alhydrogel ® was observed. Neurobehavioural changes, including decreased activity levels and altered anxiety-like behaviour, were observed compared to controls in animals exposed to 200 μg Al/kg but not at 400 and 800 μg Al/kg. Consistently, microglial number appeared increased in the ventral forebrain of the 200 μg Al/kg group. Cerebral Al levels were selectively increased in animals exposed to the lowest dose, while muscle granulomas had almost Completely disappeared at 6 months in these animals. We conclude that Alhydrogel ® injected at low dose in mouse muscle may selectively induce long-term Al cerebral accumulation and neurotoxic effects. To explain this unexpected result, an avenue that could be explored in the future relates to the adjuvant size since the injected suspensions corresponding to the lowest dose

  4. Who Is Missing from Higher Education?

    Science.gov (United States)

    Gorard, Stephen

    2008-01-01

    This paper discusses the difficulties of establishing a clear count of UK higher education students in terms of the categories used for widening participation, such as occupational background or ethnicity. Using some of the best and most complete data available, such as the annual figures from the Higher Education Statistics Agency, the paper then…

  5. Erectile dysfunction after prostate three-dimensional conformal radiation therapy. Correlation with the dose to the penile bulb

    International Nuclear Information System (INIS)

    Magli, A.; Ceschia, T.; Titone, F.; Parisi, G.; Fongione, S.; Giangreco, M.; Crespi, M.; Negri, A.; De Giorgi, G.

    2012-01-01

    Purpose: Erectile dysfunction is associated with all the common treatment options for prostate cancer. The aim of this research was to evaluate the relationship between erectile function and radiation dose to the penile bulb (PB) and other proximal penile structures in men receiving conformal radiotherapy (CRT) without hormonal therapy (HT) for prostate cancer, whose sexual function was known before treatment. Patients and methods: The study included 19 patients treated with 3D-CRT for localized prostate cancer at our department, who were self-reported to be potent before treatment, had not received HT, and had complete follow-up data available. Our evaluation was based on the International Index of Erectile Function (IIEF-5). Dose-volume histograms (DVHs) were used to evaluate the dose to the PB. Statistical analysis was performed with an unconditional logistic regression model. Results: All patients reported change in potency after radiation. Eight patients (42%) remained potent but showed a decrease of 1 or 2 levels of potency, as defined by the IIEF-5 questionnaire (reduced potency group), while 11 patients (58%) reported a change of higher levels and revealed a severe erectile dysfunction after 2 years (impotence group). Multivariate analysis of morphological and dosimetric variables yielded significance for the mean dose (p = 0.05 with an odds ratio of 1.14 and 95% CI 1-1.30). Patients receiving a mean dose of less than 50 Gy to the PB appear to have a much greater likelihood of maintaining potency. Conclusion: Our data suggest a possible existence of a dose-volume correlation between the dose applied to the PB and radiation-induced impotence. (orig.)

  6. Erectile dysfunction after prostate three-dimensional conformal radiation therapy. Correlation with the dose to the penile bulb

    Energy Technology Data Exchange (ETDEWEB)

    Magli, A.; Ceschia, T.; Titone, F.; Parisi, G.; Fongione, S. [University Hospital Udine (Italy). Dept. of Radiation Oncology; Giangreco, M. [Udine Univ. (Italy). Hygiene and Epidemiology Inst.; Crespi, M.; Negri, A. [University Hospital Udine (Italy). Dept. of Medical Physics; De Giorgi, G. [University Hospital Udine (Italy). Dept. of Urology

    2012-11-15

    Purpose: Erectile dysfunction is associated with all the common treatment options for prostate cancer. The aim of this research was to evaluate the relationship between erectile function and radiation dose to the penile bulb (PB) and other proximal penile structures in men receiving conformal radiotherapy (CRT) without hormonal therapy (HT) for prostate cancer, whose sexual function was known before treatment. Patients and methods: The study included 19 patients treated with 3D-CRT for localized prostate cancer at our department, who were self-reported to be potent before treatment, had not received HT, and had complete follow-up data available. Our evaluation was based on the International Index of Erectile Function (IIEF-5). Dose-volume histograms (DVHs) were used to evaluate the dose to the PB. Statistical analysis was performed with an unconditional logistic regression model. Results: All patients reported change in potency after radiation. Eight patients (42%) remained potent but showed a decrease of 1 or 2 levels of potency, as defined by the IIEF-5 questionnaire (reduced potency group), while 11 patients (58%) reported a change of higher levels and revealed a severe erectile dysfunction after 2 years (impotence group). Multivariate analysis of morphological and dosimetric variables yielded significance for the mean dose (p = 0.05 with an odds ratio of 1.14 and 95% CI 1-1.30). Patients receiving a mean dose of less than 50 Gy to the PB appear to have a much greater likelihood of maintaining potency. Conclusion: Our data suggest a possible existence of a dose-volume correlation between the dose applied to the PB and radiation-induced impotence. (orig.)

  7. Dose rate constants for new dose quantities

    International Nuclear Information System (INIS)

    Tschurlovits, M.; Daverda, G.; Leitner, A.

    1992-01-01

    Conceptual changes and new quantities made is necessary to reassess dose rate quantities. Calculations of the dose rate constant were done for air kerma, ambient dose equivalent and directional dose equivalent. The number of radionuclides is more than 200. The threshold energy is selected as 20 keV for the dose equivalent constants. The dose rate constant for the photon equivalent dose as used mainly in German speaking countries as a temporary quantity is also included. (Author)

  8. Dose profile in computed tomography chest scan; Perfil de dose em varredura de torax em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruno B., E-mail: bbo@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Pos-graduacao em Ciencias e Tecnologia das Radiacoes, Minerais e Materiais; Mourao, Arnaldo P. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET/MG), Belo Horizonte, MG (Brazil); Alonso, Thessa C.; Silva, Teogenes A. da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2010-07-01

    For the optimization of the patient dose in computed tomography (CT), the Brazilian legislation only established the diagnostic reference levels (DRL's) in terms of Multiple Scan Average Dose (MSAD) in a typical adult as a parameter of quality control of CT scanners. Conformity to the DRL's can be verified by measuring the dose distribution in CT scans and MSAD determination. An analysis of the quality of CT scans of the metropolitan region of Belo Horizonte is necessary by conducting pertinent tests to the study that are presented in the ANVISA (National Agency of Sanitary Vigilance) Guide. The purpose of this study is to investigate, in a chest scan, the variation of dose in CT. To measure the dose profile are used lithium fluoride thermoluminescent dosimeters (TLD-100 Rod) distributed in cylinders positioned in peripheral and central regions of a phantom of polymethylmethacrylate (PMMA). The data obtained allow us to observe the variation of the dose profile inside the phantom. The peripheral region shows higher dose values than the central region. The longitudinal variation can be observed and the maximum dose was recorded at the edges of the phantom (41,58{+-}5,10) mGy at the midpoint of the longitudinal axis. The results will contribute to disseminate the proper procedure and optimize the dosimetry and the tests of quality control in CT, as well as make a critical analysis of the DRL's. (author)

  9. Dosimetric accuracy at low monitor unit setting in electron beams at different dose rates

    International Nuclear Information System (INIS)

    Ravikumar, M.; Ravichandran, R.; Supe, Sanjay S.; Sharma, Anil K.

    1999-01-01

    As electron beam with low monitor unit (LMU) settings are used in some dosimetric studies, better understanding of accuracy in dose delivery at LMU setting is necessary. The dose measurements were carried out with 0.6 cm 3 farmer type ion chamber at d max in a polystyrene phantom. Measurements at different MUs show that the dose linearity ratio (DLR) increases as the MU setting decreases below 20 MU and DLRs are found to increase when the incident electron beams have higher energies. The increase in DLR is minimum for low dose rate setting for all five electron beam energies (6, 9, 12, 16 and 20 MeV). As the variation in dose delivery is machine-specific, a detailed study should be conducted before the low MU setting is implemented. Since errors in dose delivery are high at higher dose rates, low dose rate may be better at low MU unit setting. (author)

  10. Analysis of occupational doses of workers on the dose registry of the Federal Radiation Protection Service in 2000 and 2001

    International Nuclear Information System (INIS)

    Ogundare, F.O.; Balogun, F.A.

    2003-01-01

    In 2000 and 2001 about 279 and 221 radiation workers, respectively, were monitored by the Federal Radiation Protection Service, University of Ibadan, in Nigeria. The distribution of the occupational doses shows that the majority of workers received doses below 4 mSv in each of the two years. The radiation workers in the two years are classified into two occupational categories: medicine and industry. The mean annual effective doses, collective doses and the collective dose distribution ratios for workers in each category and the entire monitored workers were calculated. The mean annual effective doses were compared with their corresponding worldwide values quoted by UNSCEAR. In each of the two years, a few workers in industry received doses higher than 50 mSv. The collective dose distribution ratio was found to be about 0.49, which is very close to the highest value of 0.5 in the range of values considered by UNSCEAR as normal for this parameter. This suggests that extra measures have to be taken, particularly in industry, to ensure that the proportion of workers at risk does not go outside this normal range. The occupational doses were also modelled by both the log-normal and Weibull distributions. Both distributions were found to describe the data in almost the same way. (author)

  11. Distributions of neutron and gamma doses in phantom under a mixed field

    International Nuclear Information System (INIS)

    Beraud-Sudreau, E.

    1982-06-01

    A calculation program, based on Monte Carlo method, allowed to estimate the absorbed doses relatives to the reactor primary radiation, in a water cubic phantom and in cylindrical phantoms modelized from tissue compositions. This calculation is a theoretical approach of gamma and neutron dose gradient study in an animal phantom. PIN junction dosimetric characteristics have been studied experimentally. Air and water phantom radiation doses measured by PIN junction and lithium 7 fluoride, in reactor field have been compared to doses given by dosimetry classical techniques as tissue equivalent plastic and aluminium ionization chambers. Dosimeter responses have been employed to evaluate neutron and gamma doses in plastinaut (tissue equivalent plastic) and animal (piglet). Dose repartition in the piglet bone medulla has been also determined. This work has been completed by comparisons with Doerschell, Dousset and Brown results and by neutron dose calculations; the dose distribution related to lineic energy transfer in Auxier phantom has been also calculated [fr

  12. Effective dose and organ doses estimation taking tube current modulation into account with a commercial software package

    International Nuclear Information System (INIS)

    Lopez-Rendon, X.; Bosmans, H.; Zanca, F.; Oyen, R.

    2015-01-01

    To evaluate the effect of including tube current modulation (TCM) versus using the average mAs in estimating organ and effective dose (E) using commercial software. Forty adult patients (24 females, 16 males) with normal BMI underwent chest/abdomen computed tomography (CT) performed with TCM at 120 kVp, reference mAs of 110 (chest) and 200 (abdomen). Doses to fully irradiated organs (breasts, lungs, stomach, liver and ovaries) and E were calculated using two versions of a dosimetry software: v.2.0, which uses the average mAs, and v.2.2, which accounts for TCM by implementing a gender-specific mAs profile. Student's t-test was used to assess statistically significant differences between organ doses calculated with the two versions. A statistically significant difference (p < 0.001) was found for E on chest and abdomen CT, with E being lower by 4.2 % when TCM is considered. Similarly, organ doses were also significantly lower (p < 0.001): 13.7 % for breasts, 7.3 % for lungs, 9.1 % for the liver and 8.5 % for the stomach. Only the dose to the ovaries was higher with TCM (11.5 %). When TCM is used, for the stylized phantom, the doses to lungs, breasts, stomach and liver decreased while the dose to the ovaries increased. (orig.)

  13. Proceedings of an international workshop on historic dose experience and dose reduction (ALARA) at nuclear power plants

    International Nuclear Information System (INIS)

    Horan, J.R.; Baum, J.W.; Dionne, B.J.

    1985-06-01

    Dose reduction data and experience from 28 foreign and 10 US nuclear power plants was examined to determine causes for the wide variations in occupational dose from country to country. Major topics discussed were: steam generator and refueling maintenance problems; utility and supplier ALARA programs; effectiveness of dose-reduction modifications; attitudes and training; current and future dose-reduction research. While many parameters contribute to differences of occupational doses between plants from different nations, it is clear that most US plants have higher collective dose equivalent per reactor per megawatt-year than most other countries, even for plants of similar size and age. Worldwide, Finnish and Swedish plants, both PWR and BWR, have achieved the lowest values. Major factors which contribute to low doses include: (1) minimization of cobalt in primary system components exposed to water; (2) careful plant design, layout and component segregation and shielding; (3) plant standardization; (4) selection of components and systems for increased reliability; (5) management interest and commitment; (6) minimum number of workers and in-depth worker training; (7) careful control of primary system oxygen and pH; (8) good primary system water purity to minimize corrosion product formation; (9) use of special tools and robotics; (10) decontamination and passivation of primary systems and components; and (11) extent of backfitting and mandated inspections

  14. Effective dose and organ doses estimation taking tube current modulation into account with a commercial software package

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Rendon, X. [KU Leuven, Department of Imaging and Pathology, Division of Medical Physics and Quality Assessment, Herestraat 49, box 7003, Leuven (Belgium); Bosmans, H.; Zanca, F. [KU Leuven, Department of Imaging and Pathology, Division of Medical Physics and Quality Assessment, Herestraat 49, box 7003, Leuven (Belgium); University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Oyen, R. [University Hospitals Leuven, Department of Radiology, Leuven (Belgium)

    2015-07-15

    To evaluate the effect of including tube current modulation (TCM) versus using the average mAs in estimating organ and effective dose (E) using commercial software. Forty adult patients (24 females, 16 males) with normal BMI underwent chest/abdomen computed tomography (CT) performed with TCM at 120 kVp, reference mAs of 110 (chest) and 200 (abdomen). Doses to fully irradiated organs (breasts, lungs, stomach, liver and ovaries) and E were calculated using two versions of a dosimetry software: v.2.0, which uses the average mAs, and v.2.2, which accounts for TCM by implementing a gender-specific mAs profile. Student's t-test was used to assess statistically significant differences between organ doses calculated with the two versions. A statistically significant difference (p < 0.001) was found for E on chest and abdomen CT, with E being lower by 4.2 % when TCM is considered. Similarly, organ doses were also significantly lower (p < 0.001): 13.7 % for breasts, 7.3 % for lungs, 9.1 % for the liver and 8.5 % for the stomach. Only the dose to the ovaries was higher with TCM (11.5 %). When TCM is used, for the stylized phantom, the doses to lungs, breasts, stomach and liver decreased while the dose to the ovaries increased. (orig.)

  15. A users guide to the POPDOS program for evaluating collective doses

    International Nuclear Information System (INIS)

    Henning, M.J.

    1975-09-01

    A complete description is given of the input data needed to use the computer program POPDOS for estimating doses in England and Wales following atmospheric releases of radioactivity. Details are given of the Job Control Language used for normal execution of the program. A complete test case is included to facilitate program transfer to other computers. POPDOS is written in Fortran IV (level H) and is compiled under OPT = 2, using ASP3 on the IBM 370/168 computer. A list of subroutines and their functions is given together with a tabulation of the major dimensioned variables. Finally there is a description of the procedure by which a collective dose surface can be generated using the CALCOMP plotting facilities. (author)

  16. Predicting Drug Court Treatment Completion Using the MMPI-2-RF

    Science.gov (United States)

    Mattson, Curtis; Powers, Bradley; Halfaker, Dale; Akeson, Steven; Ben-Porath, Yossef

    2012-01-01

    We examined the ability of the Minnesota Multiphasic Personality Inventory-2 Restructured Form (MMPI-2-RF; Ben-Porath & Tellegen, 2008) substantive scales to predict Drug Court treatment completion in a sample of individuals identified as being at risk for failure to complete the program. Higher scores on MMPI-2-RF scales…

  17. Small dose multi-fractionation therapy, its radiobiological aspects and clinics

    International Nuclear Information System (INIS)

    Iwai, Hiroshi; Katagiri, Shiro; Furuhata, Akihiko; Fukusi, Itsuhisa

    1979-01-01

    Recent radiobiological data reveal that cell killings by small dose fractionation are almost due to nonrepairable damage with low oxygen enhancement ratio. Then, Small dose multi-fractionation method suggests a higher therapeutic-ratio than that in conventional high dose fractionated irradiation. Using these data of radiobiology, intermittent irradiations three times a day, four hours interval, with 60 - 80 rads for multi-fractionation, with high total doses of 7,200 - 7,500 rads/6.5 - 7 weeks mainly on bladder, laryngeal and esophageal tumour are applied. The results obtained are slightly improved. (author)

  18. An effective dose of ketamine for eliminating pain during injection of propofol: a dose response study.

    Science.gov (United States)

    Wang, M; Wang, Q; Yu, Y Y; Wang, W S

    2013-09-01

    Ketamine can completely eliminate pain associated with propofol injection. However, the effective dose of ketamine to eliminate propofol injection pain has not been determined. The purpose of this study was to determine the effective dose of ketamine needed to eliminate pain in 50% and 95% of patients (ED50 and ED95, respectively) during propofol injections. This study was conducted in a double-blinded fashion and included 50 patients scheduled for elective gynecological laparoscopy under general anesthesia. The initial dose of ketamine used in the first patient was 0.25mg/kg. The dosing modifications were in increments or decrements of 0.025 mg/kg. Ketamine was administered 15 seconds before injecting propofol (2.5mg/kg), which was injected at a rate of 1mL/s. Patients were asked to rate their pain during propofol injection every 5s econds using a 0-3 pain scale. The highest pain score was recorded. The ED50, ED95 and 95% confidence intervals (CI) were determined by probit analyses. The dose of ketamine ranged from 0.175 to 0.275 mg/kg. The ED50 and ED95 of ketamine for eliminating pain during propofol injection were 0.227 mg/kg and 0.283 mg/kg, respectively (95%CI: 0.211-0.243 mg/kg and 0.26-0.364 mg/kg, respectively). Ketamine at an approximate dose of 0.3mg/kg was effective in eliminating pain during propofol injection. Copyright © 2013 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  19. Fractional dosing of yellow fever vaccine to extend supply: a modelling study.

    Science.gov (United States)

    Wu, Joseph T; Peak, Corey M; Leung, Gabriel M; Lipsitch, Marc

    2016-12-10

    The ongoing yellow fever epidemic in Angola strains the global vaccine supply, prompting WHO to adopt dose sparing for its vaccination campaign in Kinshasa, Democratic Republic of the Congo, in July-August, 2016. Although a 5-fold fractional-dose vaccine is similar to standard-dose vaccine in safety and immunogenicity, efficacy is untested. There is an urgent need to ensure the robustness of fractional-dose vaccination by elucidation of the conditions under which dose fractionation would reduce transmission. We estimate the effective reproductive number for yellow fever in Angola using disease natural history and case report data. With simple mathematical models of yellow fever transmission, we calculate the infection attack rate (the proportion of population infected over the course of an epidemic) with various levels of transmissibility and 5-fold fractional-dose vaccine efficacy for two vaccination scenarios, ie, random vaccination in a hypothetical population that is completely susceptible, and the Kinshasa vaccination campaign in July-August, 2016, with different age cutoff for fractional-dose vaccines. We estimate the effective reproductive number early in the Angola outbreak was between 5·2 and 7·1. If vaccine action is all-or-nothing (ie, a proportion of vaccine recipients receive complete protection [VE] and the remainder receive no protection), n-fold fractionation can greatly reduce infection attack rate as long as VE exceeds 1/n. This benefit threshold becomes more stringent if vaccine action is leaky (ie, the susceptibility of each vaccine recipient is reduced by a factor that is equal to the vaccine efficacy). The age cutoff for fractional-dose vaccines chosen by WHO for the Kinshasa vaccination campaign (2 years) provides the largest reduction in infection attack rate if the efficacy of 5-fold fractional-dose vaccines exceeds 20%. Dose fractionation is an effective strategy for reduction of the infection attack rate that would be robust with a

  20. Fractional Dosing of Yellow Fever Vaccine to Extend Supply: A Modeling Study

    Science.gov (United States)

    Peak, Corey M.; Leung, Gabriel M.

    2016-01-01

    Background The ongoing yellow fever (YF) epidemic in Angola strains the global vaccine supply, prompting WHO to adopt dose sparing for its vaccination campaign in Kinshasa in July–August 2016. Although a 5-fold fractional-dose vaccine is similar to standard-dose vaccine in safety and immunogenicity, efficacy is untested. There is an urgent need to ensure the robustness of fractional-dose vaccination by elucidating the conditions under which dose fractionation would reduce transmission. Methods We estimate the effective reproductive number for YF in Angola using disease natural history and case report data. With simple mathematical models of YF transmission, we calculate the infection attack rate (IAR, the proportion of population infected over the course of an epidemic) under varying levels of transmissibility and five-fold fractional-dose vaccine efficacy for two vaccination scenarios: (i) random vaccination in a hypothetical population that is completely susceptible; (ii) the Kinshasa vaccination campaign in July–August 2016 with different age cutoff for fractional-dose vaccines. Findings We estimate the effective reproductive number early in the Angola outbreak was between 5·2 and 7·1. If vaccine action is all-or-nothing (i.e. a proportion VE of vaccinees receives complete and the remainder receive no protection), n-fold fractionation can dramatically reduce IAR as long as efficacy VE exceeds 1/n. This benefit threshold becomes more stringent if vaccine action is leaky (i.e. the susceptibility of each vaccinee is reduced by a factor that is equal to the vaccine efficacy VE). The age cutoff for fractional-dose vaccines chosen by the WHO for the Kinshasa vaccination campaign (namely, 2 years) provides the largest reduction in IAR if the efficacy of five-fold fractional-dose vaccines exceeds 20%. Interpretation Dose fractionation is a very effective strategy for reducing infection attack rate that would be robust with a large margin for error in case

  1. An evaluation of total disintegration time for three different doses of sublingual fentanyl tablets in patients with breakthrough pain.

    Science.gov (United States)

    Nalamachu, Srinivas

    2013-12-01

    Breakthrough pain is common among patients with cancer and presents challenges to effective pain management. Breakthrough pain is characterized by rapid onset, severe intensity, and duration typically lasting disintegration time of three different doses of sublingual fentanyl tablets in opioid-tolerant patients. This was a single-center, non-randomized, open-label study. Opioid-tolerant adult patients (N = 30) with chronic pain were assigned to one of three dose groups and self-administered a single 100, 200, or 300 μg sublingual fentanyl tablet (Abstral(®), Galena Biopharma, Portland, OR, USA). Time to complete disintegration was measured by each patient with a stopwatch and independently verified by study personnel. Disintegration time (mean ± SD) for sublingual fentanyl tablets (all doses) was 88.2 ± 55.1 s. Mean disintegration times tended to be slightly longer for the 200 μg (96.7 ± 57.9 s) and 300 μg doses (98.6 ± 64.8 s) compared to the 100 μg dose (69.5 ± 40.5 s). Differences were not statistically significant. Disintegration time was not significantly different between men and women and was not affected by age. Sublingual fentanyl tablets dissolved rapidly (average time <2 min) in all patients, with the higher doses taking slightly more time to dissolve.

  2. High dose rate (HDR) and low dose rate (LDR) interstitial irradiation (IRT) of the rat spinal cord

    International Nuclear Information System (INIS)

    Pop, Lucas A.M.; Plas, Mirjam van der; Skwarchuk, Mark W.; Hanssen, Alex E.J.; Kogel, Albert J. van der

    1997-01-01

    Purpose: To describe a newly developed technique to study radiation tolerance of rat spinal cord to continuous interstitial irradiation (IRT) at different dose rates. Material and methods: Two parallel catheters are inserted just laterally on each side of the vertebral bodies from the level of Th 10 to L 4 . These catheters are afterloaded with two 192 Ir wires of 4 cm length each (activity 1-2.3 mCi/cm) for the low dose rate (LDR) IRT or connected to the HDR micro-Selectron for the high dose rate (HDR) IRT. Spinal cord target volume is located at the level of Th 12 -L 2 . Due to the rapid dose fall-off around the implanted sources, a dose inhomogeneity across the spinal cord thickness is obtained in the dorso-ventral direction. Using the 100% reference dose (rate) at the ventral side of the spinal cord to prescribe the dose, experiments have been carried out to obtain complete dose response curves at average dose rates of 0.49, 0.96 and 120 Gy/h. Paralysis of the hind-legs after 5-6 months and histopathological examination of the spinal cord of each irradiated rat are used as experimental endpoints. Results: The histopathological damage seen after irradiation is clearly reflected the inhomogeneous dose distribution around the implanted catheters, with the damage predominantly located in the dorsal tract of the cord or dorsal roots. With each reduction in average dose rate, spinal cord radiation tolerance is significantly increased. When the dose is prescribed at the 100% reference dose rate, the ED 50 (induction of paresis in 50% of the animals) for the HDR-IRT is 17.3 Gy. If the average dose rate is reduced from 120 Gy/h to 0.96 or 0.49 Gy/h, a 2.9- or 4.7-fold increase in the ED 50 values to 50.3 Gy and 80.9 Gy is observed; for the dose prescribed at the 150% reference dose rate (dorsal side of cord) ED 50 values are 26.0, 75.5 and 121.4 Gy, respectively. Using different types of analysis and in dependence of the dose prescription and reference dose rate, the

  3. The Legalization of Higher Education

    Science.gov (United States)

    Badke, Lara K.

    2017-01-01

    A complete discussion of intellectual property (IP), faculty rights, and the public good requires a thorough framing of higher education's legal context, from which the rise of legalistic criteria (or legalization) and current IP regime have grown.

  4. Studies on adaptive response of lymphocyte transformation induced by low-dose irradiation

    International Nuclear Information System (INIS)

    Du Zeji; Su Liaoyuan; Tian Hailin; Zou Huawei

    1995-10-01

    Human peripheral blood lymphocytes stimulated by mitogen in vitro for 24 h were exposed to low-dose γ-ray irradiation (0.5∼4.0 cGy, adaptive dose). They showed an adaptive response to the inhibition of 3 H-TdR incorporation by subsequent higher acute doses of γ-ray (challenge dose). At the interval of 24 h between adaptive dose and challenge dose, the strongest adaptive response induced by low-dose irradiation was found. It is also found that the response induced by 1.0 cGy of adaptive dose was more obvious than that by other doses and that 3.0 Gy of challenge dose produced the strongest adaptive response. As the challenge doses increased, the adaptive response reduced. (2 figs., 2 tabs.)

  5. High-dose contrast-enhanced MRI in multiple sclerosis

    International Nuclear Information System (INIS)

    Koudriavtseva, T.; Pozzilli, C.; Di Biasi, C.; Iannilli, M.; Trasimeni, G.; Gasperini, C.; Argentino, C.; Gualdi, G.F.

    1996-01-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs

  6. High-dose contrast-enhanced MRI in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Koudriavtseva, T. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Pozzilli, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Di Biasi, C. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Iannilli, M. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Trasimeni, G. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Gasperini, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Argentino, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Gualdi, G.F. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy)

    1996-05-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs.

  7. Sodium phenylbutyrate in Huntington's disease: a dose-finding study.

    Science.gov (United States)

    Hogarth, Penelope; Lovrecic, Luca; Krainc, Dimitri

    2007-10-15

    Transcriptional dysregulation in Huntington's disease (HD) is mediated in part by aberrant patterns of histone acetylation. We performed a dose-finding study in human HD of sodium phenylbutyrate (SPB), a histone deacetylase inhibitor that ameliorates the HD phenotype in animal models. We used a dose-escalation/de-escalation design, using prespecified toxicity criteria and standard clinical and laboratory safety measures. The maximum tolerated dose was 15 g/day. At higher doses, toxicity included vomiting, lightheadedness, confusion, and gait instability. We saw no significant laboratory or electrocardiographic abnormalities. Gene expression changes in blood suggested an inverse dose-response. In conclusion, SPB at 12 to 15 g/day appears to be safe and well-tolerated in human HD. 2007 Movement Disorder Society

  8. Comparison of scatter doses from a multislice and a single slice CT scanner

    International Nuclear Information System (INIS)

    Burrage, J. W.; Causer, D. A.

    2006-01-01

    During shielding calculations for a new multislice CT (MSCT) scanner it was found that the manufacturer's data indicated significantly higher external scatter doses than would be generated for a single slice CT (SSCT). Even allowing for increased beam width, the manufacturer's data indicated that the scatter dose per scan was higher by a factor of about 3 to 4. The magnitude of the discrepancy was contrary to expectations and also contrary to a statement by the UK ImPACT group, which indicated that when beam width is taken into account, the scatter doses should be similar. The matter was investigated by comparing scatter doses from an SSCT and an MSCT. Scatter measurements were performed at three points using a standard perspex CTDI phantom, and CT dose indices were also measured to compare scanner output. MSCT measurements were performed with a 40 mm wide beam, SSCT measurements with a 10 mm wide beam. A film badge survey was also performed after the installation of the MSCT scanner to assess the adequacy of lead shielding in the room. It was found that the scatter doses from the MSCT were lower than indicated by the manufacturer's data. MSCT scatter doses were approximately 4 times higher than those from the SSCT, consistent with expectations due to beam width differences. The CT dose indices were similar, and the film badge survey indicated that the existing shielding, which had been adequate for the SSCT, was also adequate for the MSCT

  9. [Evaluation of Organ Dose Estimation from Indices of CT Dose Using Dose Index Registry].

    Science.gov (United States)

    Iriuchijima, Akiko; Fukushima, Yasuhiro; Ogura, Akio

    Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, dedicated software is too expensive for small scale hospitals. Not every hospital can estimate organ dose with dedicated software. The purpose of this study was to evaluate the simple method of organ dose estimation using some common indices of CT dose. The Monte Carlo simulation software Radimetrics (Bayer) was used for calculating organ dose and analysis relationship between indices of CT dose and organ dose. Multidetector CT scanners were compared with those from two manufactures (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). Using stored patient data from Radimetrics, the relationships between indices of CT dose and organ dose were indicated as each formula for estimating organ dose. The accuracy of estimation method of organ dose was compared with the results of Monte Carlo simulation using the Bland-Altman plots. In the results, SSDE was the feasible index for estimation organ dose in almost organs because it reflected each patient size. The differences of organ dose between estimation and simulation were within 23%. In conclusion, our estimation method of organ dose using indices of CT dose is convenient for clinical with accuracy.

  10. Research of z-axis geometric dose efficiency in multi-detector computed tomography

    International Nuclear Information System (INIS)

    Kim, You Hyun; Kim, Moon Chan

    2006-01-01

    With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for

  11. Iodine-129 Dose in LLW Disposal Facility Performance Assessments

    International Nuclear Information System (INIS)

    Wilhite, E.L.

    1999-01-01

    Iodine-129 has the lowest Performance Assessment derived inventory limit in SRS disposal facilities. Because iodine is concentrated in the body to one organ, the thyroid, it has been thought that dilution with stable iodine would reduce the dose effects of 129I.Examination of the dose model used to establish the Dose conversion factor for 129I shows that, at the levels considered in performance assessments of low-level waste disposal facilities, the calculated 129I dose already accounts for ingestion of stable iodine. At higher than normal iodine ingestion rates, the uptake of iodine by the thyroid itself decrease, which effectively cancels out the isotopic dilution effect

  12. Prediction of late rectal complication following high-dose-rate intracavitary brachytherapy in cancer of the uterine cervix

    International Nuclear Information System (INIS)

    Lee, Jeung Eun; Huh, Seung Jae; Park, Won; Lim, Do Hoon; Ahn, Yong Chan

    2003-01-01

    Although high-dose-rate intracavitary radiotherapy (HDR ICR) has been used in the treatment of cervical cancer, the potential for increased risk of late complication, most commonly in the rectum, is a major concern. We have previously reported on 136 patients treated with HDR brachytherapy between 1995 and 1999. The purpose of this study is to upgrade the previous data and confirm the correlation between late rectal complication and rectal dose in cervix cancer patients treated with HDR ICR. A retrospective analysis was performed for 222 patients with cervix cancer who were treated for curative intent with extemal beam radiotherapy (EBRT) and HDR ICR from July 1995 to December 2001. The median dose of EBRT was 50.4 (30.6-56.4) Gy with a daily fraction size 1.8 Gy. A total of six fractions of HDR ICR were given twice weekly with fraction size of 4 (3-5.5) Gy to A point by Iridium-192 source. The rectal dose was calculated at the rectal reference point using the barium contrast criteria in vivo measurement of the rectal dose was performed with thermoluminescent dosimeter (TLD) during HDR ICR. The median follow-up period was 39 months, ranging from 6 to 90 months. Twenty-one patients (9.5%) experienced late rectal bleeding, from 3 to 44 months (median, 13 months) after the completion of RT. The calculated rectal doses were not different between the patients with rectal bleeding and those without, but the measured rectal doses were higher in the complicated patients. The differences of the measured ICR rectal fractional dose, ICR total rectal dose, and total rectal biologically equivalent dose (BED) were statistically significant. When the measured ICR total rectal dose was beyond 16 Gy, when the ratio of the measured rectal dose to A point dose was beyond 70%, or when the measured rectal BED was over 110 GY 3 , a high possibility of late rectal complication was found. Late rectal complication was closely correlated with measured rectal dose by in vivo dosimetry using

  13. A 3-lever discrimination procedure reveals differences in the subjective effects of low and high doses of MDMA.

    Science.gov (United States)

    Harper, David N; Langen, Anna-Lena; Schenk, Susan

    2014-01-01

    Drug discrimination studies have suggested that the subjective effects of low doses of (±)3,4-methylenedioxymethamphetamine (MDMA) are readily differentiated from those of d-amphetamine (AMPH) and that the discriminative stimulus properties are mediated by serotonergic and dopaminergic mechanisms, respectively. Previous studies, however, have primarily examined responses to doses that do not produce substantial increases in extracellular dopamine. The present study determined whether doses of MDMA that produce increases in synaptic dopamine would also produce subjective effects that were more like AMPH and were sensitive to pharmacological manipulation of D1-like receptors. A three-lever drug discrimination paradigm was used. Rats were trained to respond on different levers following saline, AMPH (0.5mg/kg, IP) or MDMA (1.5mg/kg, IP) injections. Generalization curves were generated for a range of different doses of both drugs and the effect of the D1-like antagonist, SCH23390 on the discriminative stimulus effects of different doses of MDMA was determined. Rats accurately discriminated MDMA, AMPH and saline. Low doses of MDMA produced almost exclusive responding on the MDMA lever but at doses of 3.0mg/kg MDMA or higher, responding shifted to the AMPH lever. The AMPH response produced by higher doses of MDMA was attenuated by pretreatment with SCH23390. The data suggest that low doses and higher doses of MDMA produce distinct discriminative stimuli. The shift to AMPH-like responding following administration of higher doses of MDMA, and the decrease in this response following administration of SCH23390 suggests a dopaminergic component to the subjective experience of MDMA at higher doses. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Bronchodilator Efficacy of Single Doses of Indacaterol in Japanese Patients with COPD: A Randomised, Double-Blind, Placebo-Controlled Trial

    Directory of Open Access Journals (Sweden)

    Motokazu Kato

    Full Text Available ABSTRACT: Background: Indacaterol is an investigational, novel, inhaled once-daily ultra-long-acting beta-2 agonist for the treatment of chronic obstructive pulmonary disease (COPD. This study evaluated the 24-h bronchodilatory efficacy and safety of indacaterol in Japanese patients with COPD. Methods: This Phase-II, randomised, placebo-controlled, crossover study comprised four double-blind, single-dose treatment periods (washout between periods: 14-28 days. Japanese patients aged 40-75 years with moderate-to-severe COPD were randomised to receive single doses of indacaterol (150, 300, or 600 μg or placebo via a single-dose dry-powder inhaler. Efficacy (primary endpoint: standardised FEV1AUC22-24h and safety were assessed for 24 h post-dose in each treatment period. Results: Of the 50 patients randomised (92% male; mean age, 67.2 years, 45 completed the study. Standardised FEV1AUC22-24h was significantly higher for all indacaterol doses as compared with placebo, with clinically relevant differences of 130, 160, and 170 mL for 150, 300, and 600 μg, respectively (P < 0.001. The improvement in FEV1 was seen as early as 5 min post-dose with indacaterol and sustained for 24 h (P < 0.001 vs placebo at all time points. All indacaterol doses were well tolerated and showed no clinically meaningful effect on pulse rate, blood pressure, QTc interval, and laboratory parameters when compared with placebo. Conclusions: In the Japanese COPD population studied, single doses of indacaterol (150, 300, and 600 μg provided sustained 24-h bronchodilation, with onset of action within 5 min post-dose. All doses were well tolerated. These results are consistent with data from Caucasian populations. KEY WORDS: beta2-agonists, bronchodilator, COPD, efficacy, indacaterol

  15. Higher physics for CFE with answers

    CERN Document Server

    Chambers, Paul; Moore, Ian

    2013-01-01

    The only new textbook appropriate for all new Higher Physics syllabus requirements from 2012 onwards Higher Physics for CfE provides complete coverage of the latest SQA syllabus for the Revised Higher (for examination 2012 onwards), and is also tailored specifically to the extended requirements, teaching approaches and syllabus outlines detailed in the Higher revisions for Curriculum for Excellence. Each section of the book matches a unit of the CfE syllabus; each chapter corresponds to a content area. The text is composed of three units: Our Dynamic Universe, Particles and Waves, and Electric

  16. Risks to health from radiation at low dose rates

    International Nuclear Information System (INIS)

    Gentner, N.E.; Osborne, R.V.

    1997-01-01

    Our focus is on whether, using a balance-of-evidence approach, it is possible to say that at a low enough dose, or at a sufficiently low dose rate, radiation risk reduces to zero in a population. We conclude that insufficient evidence exists at present to support such a conclusion. In part this reflects statistical limitations at low doses, and in part (although mechanisms unquestionably exist to protect us against much of the damage induced by ionizing radiation) the biological heterogeneity of human populations, which means these mechanisms do not act in all members of the population at all times. If it is going to be possible to demonstrate that low doses are less dangerous than we presently assume, the evidence, paradoxically, will likely come from studies of higher dose and dose rate scenarios than are encountered occupationally. (author)

  17. Radiation dose to the patient in radionuclide studies

    International Nuclear Information System (INIS)

    Roedler, H.D.

    1981-01-01

    In medical radionuclide studies, the radiation risk has to be considered in addition to the general risk of administering a pharmaceutical. As radiation exposure is an essential factor in radiation risk estimation, some aspects of internal dose calculation, including radiation risk assessments, are treated. The formalism of current internal dose calculation is presented. The input data, especially the residence time and the absorbed dose per transformation, their origin and accuracy are discussed. Results of internal dose calculations for the ten most frequently used radionuclide studies are presented as somatically effective dose equivalents. The accuracy of internal dose calculation is treated in detail by considering the biokinetics of the radiopharmaceutical, the phantoms used for dose calculations, the absorbed dose per transformation, the administered activity, and the transfer of the dose, calculated for a phantom, to the patient. The internal dose calculated for a reference phantom may be assumed to be in accordance with the actual patient dose within a range described by a factor of about two to three. Finally, risk estimates for nuclear medicine procedures are quantified, being generally of sixth order. The radiation risk from the radioiodine test is comparably higher, but probably lower than calculated according to the UNSCEAR risk coefficients. However, further studies are needed to confirm these preliminary results and to improve the quantification of the radiation risk from the medical use of radionuclides. (author)

  18. Approximate distribution of dose among foetal organs for radioiodine uptake via placenta transfer

    Science.gov (United States)

    Millard, R. K.; Saunders, M.; Palmer, A. M.; Preece, A. W.

    2001-11-01

    Absorbed radiation doses to internal foetal organs were calculated according to the medical internal radiation dose (MIRD) technique in this study. Anthropomorphic phantoms of the pregnant female as in MIRDOSE3 enabled estimation of absorbed dose to the whole foetus at two stages of gestation. Some foetal organ self-doses could have been estimated by invoking simple spherical models for thyroid, liver, etc, but we investigated the use of the MIRDOSE3 new-born phantom as a surrogate for the stage 3 foetus, scaled to be compatible with total foetal body mean absorbed dose/cumulated activity. We illustrate the method for obtaining approximate dose distribution in the foetus near term following intake of 1 MBq of 123I, 124I, 125I or 131I as sodium iodide by the mother using in vivo biodistribution data examples from a good model of placenta transfer. Doses to the foetal thyroid of up to 1.85 Gy MBq-1 were predicted from the 131I uptake data. Activity in the foetal thyroid was the largest contributor to absorbed dose in the foetal body, brain, heart and thymus. Average total doses to the whole foetus ranged from 0.16 to 1.2 mGy MBq-1 for stages 1 and 3 of pregnancy using the MIRDOSE3 program, and were considerably higher than those predicted from the maternal contributions alone. Doses to the foetal thymus and stomach were similar, around 2-3 mGy MBq-1. Some foetal organ doses from the radioiodides were ten times higher than to the corresponding organs of the mother, and up to 100 times higher to the thyroid. The fraction of activity uptakes in foetal organs were distributed similarly to the maternal ones.

  19. Approximate distribution of dose among foetal organs for radioiodine uptake via placenta transfer

    Energy Technology Data Exchange (ETDEWEB)

    Millard, R.K. [Medical Physics Research Centre, Bristol Oncology Centre, Bristol (United Kingdom)]. E-mail: rkmillard_69@yahoo.co.uk; Saunders, M.; Palmer, A.M.; Preece, A.W. [Medical Physics Research Centre, Bristol Oncology Centre, Bristol (United Kingdom)

    2001-11-01

    Absorbed radiation doses to internal foetal organs were calculated according to the medical internal radiation dose (MIRD) technique in this study. Anthropomorphic phantoms of the pregnant female as in MIRDOSE3 enabled estimation of absorbed dose to the whole foetus at two stages of gestation. Some foetal organ self-doses could have been estimated by invoking simple spherical models for thyroid, liver, etc, but we investigated the use of the MIRDOSE3 new-born phantom as a surrogate for the stage 3 foetus, scaled to be compatible with total foetal body mean absorbed dose/cumulated activity. We illustrate the method for obtaining approximate dose distribution in the foetus near term following intake of 1 MBq of {sup 123}I, {sup 124}I, {sup 125}I or {sup 131}I as sodium iodide by the mother using in vivo biodistribution data examples from a good model of placenta transfer. Doses to the foetal thyroid of up to 1.85 Gy MBq{sup -1} were predicted from the {sup 131}I uptake data. Activity in the foetal thyroid was the largest contributor to absorbed dose in the foetal body, brain, heart and thymus. Average total doses to the whole foetus ranged from 0.16 to 1.2 mGy MBq{sup -1} for stages 1 and 3 of pregnancy using the MIRDOSE3 program, and were considerably higher than those predicted from the maternal contributions alone. Doses to the foetal thymus and stomach were similar, around 2-3 mGy MBq{sup -1}. Some foetal organ doses from the radioiodides were ten times higher than to the corresponding organs of the mother, and up to 100 times higher to the thyroid. The fraction of activity uptakes in foetal organs were distributed similarly to the maternal ones. (author)

  20. Dosing of traces of oxygenated water by polarography

    International Nuclear Information System (INIS)

    Faure, A.M.; Malterre, J.

    1960-01-01

    As dosing oxygenated water by using polarography has been envisaged within the framework of water purity controls for the Melusine pile, the objective of the authors is here to see whether the polarographic method could be satisfying for routine analyses, and would result in a higher dosing sensitivity. They describe the polarography principle, indicate devices which are used, specify and comment conditions under which polarography is performed [fr

  1. Higher-derivative Lee-Wick unification

    International Nuclear Information System (INIS)

    Carone, Christopher D.

    2009-01-01

    We consider gauge coupling unification in Lee-Wick extensions of the Standard Model that include higher-derivative quadratic terms beyond the minimally required set. We determine how the beta functions are modified when some Standard Model particles have two Lee-Wick partners. We show that gauge coupling unification can be achieved in such models without requiring the introduction of additional fields in the higher-derivative theory and we comment on possible ultraviolet completions.

  2. Time and dose-related changes in the thickness of pig skin after irradiation with single doses of 90Sr/90Y β-rays

    International Nuclear Information System (INIS)

    Rezvani, M.; Hamlet, R.; Hopewell, J.W.; Sieber, V.K.

    1994-01-01

    Time-related changes in pig skin thickness have been evaluated using a non-invasive ultrasound technique after exposure to a range of single doses of 90 Sr/ 90 Yr β-rays. The reduction in relative skin thickness developed in two distinct phases: the first was between 12 and 20 weeks postirradiation. No further changes were then seen until 52 weeks postirradiation when a second phase of skin thinning was observed. This was complete after 76 weeks and no further changes in relative skin thickness were seen in the maximum follow up period of 129 weeks. The timings of these phases of damage were independent of the radiation dose, however, the severity of both phases of radiation-induced skin thinning were dose related. (Author)

  3. Radiation dose to procedural personnel and patients from an X-ray volume imaging system

    International Nuclear Information System (INIS)

    Paul, Jijo; Mbalisike, Emmanuel C.; Vogl, Thomas J.

    2013-01-01

    To evaluate the radiation dose received by procedural personnel and patients from an X-ray volume imaging (XVI) system during interventional procedures. Forty patients were examined using catheter angiography (group A), digital subtraction angiography (group B) and cone-beam CT (CBCT, group C). Doses to procedural personnel (using thermo-luminescent dosimeters, TLDs) and patients were estimated. Image quality and lesion delineation were assessed using objective and subjective methods. Shapiro-Wilk, two-sided Student's t and Wilcoxon matched-pairs tests were used to test statistical significance. Doses (milligrays) measured in the hands and left knee of the interventionist were higher than those in an assistant physician (P < 0.05). Doses (dose-area product and skin entry dose) were lower in group A and higher in C compared with other groups; moreover, comparison among the groups were significant (all P = 0.0001). Subjective and objective lesion delineation showed significant results (all P < 0.05) among the tumour types considered. Image quality estimation showed the opposite results for objective and subjective analysis. More doses were obtained for hands of the procedural personnel compared to other anatomical regions measured. Catheter angiography showed lower dose compared with other imaging groups examined. Lesion delineation was clearly possible using CBCT. Objective and subjective analysis showed the opposite results regarding image quality because of higher noise levels and artefacts. (orig.)

  4. Pulsed Dose Rate (PDR - BT) brachytherapy in treatment of breast cancer

    International Nuclear Information System (INIS)

    Skowronek, J.

    2007-01-01

    Breast conserving surgery (BCS) and radiotherapy (EBRT) of the conserved breast became widely accepted in the last decades for the treatment of early invasive breast cancer. The standard technique of RT after breast conservation is to treat the whole breast up to a total dose of 45 to 50 Gy. Initially brachytherapy for breast cancer was used in addition of external radiation to boost a portion of the breast to higher doses. However, over the past 10 years, the application of brachytherapy in breast cancer has changed. In early stage breast cancer, research has shown that the area that requires radiation treatment to prevent the cancer from returning is the breast tissue that surrounds the area where the initial cancer was removed. Because this typically includes only a part of the breast, brachytherapy is now being used to treat the targeted portion of the breast and as a result allows accelerated delivery of the radiation dose so that treatment is completed in four to five days. Another indications for PDR - BT as a part of treatment in locally advanced breast cancer or as a palliative treatment are discussed in the paper, too. Preliminary results with PDR - BT boost technique are promising. However, more experience and longer follow-up are required to define whether these methods might improve local tumor control for breast cancer patients. In this article the current status, indications, technical aspects and published results of PDR brachytherapy (PDR - BT) in breast cancer treatment are reviewed. (author)

  5. p-MOSFET total dose dosimeter

    Science.gov (United States)

    Buehler, Martin G. (Inventor); Blaes, Brent R. (Inventor)

    1994-01-01

    A p-MOSFET total dose dosimeter where the gate voltage is proportional to the incident radiation dose. It is configured in an n-WELL of a p-BODY substrate. It is operated in the saturation region which is ensured by connecting the gate to the drain. The n-well is connected to zero bias. Current flow from source to drain, rather than from peripheral leakage, is ensured by configuring the device as an edgeless MOSFET where the source completely surrounds the drain. The drain junction is the only junction not connected to zero bias. The MOSFET is connected as part of the feedback loop of an operational amplifier. The operational amplifier holds the drain current fixed at a level which minimizes temperature dependence and also fixes the drain voltage. The sensitivity to radiation is made maximum by operating the MOSFET in the OFF state during radiation soak.

  6. Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques

    International Nuclear Information System (INIS)

    Tricarico, Francesco; Hlavacek, Anthony M.; Schoepf, U.J.; Ebersberger, Ullrich; Nance, John W.; Vliegenthart, Rozemarijn; Cho, Young Jun; Spears, J.R.; Secchi, Francesco; Savino, Giancarlo; Marano, Riccardo; Bonomo, Lorenzo; Schoenberg, Stefan O.; Apfaltrer, Paul

    2013-01-01

    To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P < 0.001), while SNR and CNR were higher (P < 0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P < 0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P < 0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. (orig.)

  7. Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Tricarico, Francesco [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Catholic University of the Sacred Heart, ' ' A. Gemelli' ' Hospital, Department of Bioimaging and Radiological Sciences, Rome (Italy); Hlavacek, Anthony M. [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Children' s Hospital, Medical University of South Carolina, Division of Pediatric Cardiology, Charleston, SC (United States); Schoepf, U.J. [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Children' s Hospital, Medical University of South Carolina, Division of Pediatric Cardiology, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Ebersberger, Ullrich [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Heart Centre Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich (Germany); Nance, John W. [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Johns Hopkins Hospital, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Vliegenthart, Rozemarijn [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); University Medical Centre Groningen/University of Groningen, Centre for Medical Imaging - North East Netherlands, Department of Radiology, Groningen (Netherlands); Cho, Young Jun [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Konyang University School of Medicine, Department of Radiology, Daejeon (Korea, Republic of); Spears, J.R. [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Secchi, Francesco [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Milan School of Medicine IRCCS Policlinico San Donato, Department of Medical and Surgical Sciences, Radiology Unit, Milan (Italy); Savino, Giancarlo; Marano, Riccardo; Bonomo, Lorenzo [Catholic University of the Sacred Heart, ' ' A. Gemelli' ' Hospital, Department of Bioimaging and Radiological Sciences, Rome (Italy); Schoenberg, Stefan O. [University Medical Centre Mannheim, Medical Faculty Mannheim - Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, Mannheim (Germany); Apfaltrer, Paul [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); University Medical Centre Mannheim, Medical Faculty Mannheim - Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, Mannheim (Germany)

    2013-05-15

    To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P < 0.001), while SNR and CNR were higher (P < 0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P < 0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P < 0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. (orig.)

  8. The impact of postimplant edema on the urethral dose in prostate brachytherapy

    International Nuclear Information System (INIS)

    Waterman, Frank M.; Dicker, Adam P.

    2000-01-01

    Purpose: The objective of this work is to determine the effect of timing of the postimplant CT scan on the assessment of the urethral dose. Methods and Materials: A preimplant CT scan and two postimplant CT scans were obtained on 50 patients who received I-125 prostate seed implants. The first postimplant CT scan was obtained on the day of the implant; the second usually 4 to 9 weeks later (mean: 46 no. +-no. 23 days; range: 27-135 days). The urethra was localized in each postimplant CT scan and a dose-volume histogram (DVH) of the urethral dose was compiled from each CT study. The relative decrease in the prostate volume between the first and second postimplant CT scans was determined by contouring the prostate in each CT scan. Results: The prostate volume decreased by 27 no. +-no. 9% (mean no. +-no. SD) between the first and second postimplant CT scans. As a result, the averaged urethral dose derived from the second CT scan was about 30% higher. In terms of dose, the D 10 , D 25 , D 50 , D 75 , and D 90 urethral doses derived from the second CT scan were 90 no. +-no. 56 Gy, 81 no. +-no. 49 Gy, 67 no. +-no. 42 Gy, 49 no. +-no. 44 Gy, and 40 no. +-no. 46 Gy higher, respectively. The increase in the urethral dose is correlated with the decrease in the prostate volume (R = 0.57, no. rhono. 10 dose derived from the CT scans obtained at 46 no. +-no. 23 days postimplant was 90 no. +-no. 56 Gy higher than that derived from the CT scans obtained on the day of the implant. Because of this large difference, the timing of the postimplant CT scan needs to be specified when specifying dose thresholds for urethral morbidity

  9. Dose-response relationship of γ-ray-induced reciprocal translocations at low doses in spermatogonia of the crab-eating monkey (Macaca fascicularis)

    International Nuclear Information System (INIS)

    Matsuda, Yoichi; Tobari, Izuo; Yamagiwa, Junji; Utsugi, Toyoko; Okamoto, Masanori; Nakai, Sayaka

    1985-01-01

    The yield of translocations induced by acute γ-irradiation at low doses in the crab-eating monkey's (Macaca fascicularis) spermatogonia was examined. Over the low dose range from 0 to 1 Gy, the dose-response relationship for translocation yield was a linear one. To estimate the sensitivity to the induction of translocations in the crab-eating monkey's spermatogonia, the slope of the regression line was compared with those in other mammalian species. Consequently, over the low dose range below 1 Gy, the sensitivity of the crab-eating monkey's spermatogonia to translocation induction was similar to several mammalian species, the mouse, Chinese hamster, and the rabbit, but significantly higher than that of the rhesus monkey and lower than that of the marmoset. (Auth.)

  10. Effect of weekly high-dose vitamin D3 supplementation on serum cholecalciferol concentrations in pregnant women.

    Science.gov (United States)

    Dimitris, Michelle C; Perumal, Nandita; Craig-Barnes, Hayley A; Leadley, Michael; Mahmud, Abdullah A; Baqui, Abdullah H; Roth, Daniel E

    2016-04-01

    Vitamin D status is conventionally defined by the serum concentration of 25-hydroxyvitamin D. However, it has been proposed that the serum cholecalciferol concentration (D3) also determines functional vitamin D sufficiency. The objective of this study was to describe the effect of weekly high-dose vitamin D3 supplementation on inter-dose serum D3 in pregnant women. We conducted a sub-study of a completed randomized double-blind placebo-controlled trial of vitamin D3 (35,000 IU/week) supplementation in late pregnancy (AViDD trial) in Dhaka, Bangladesh. This study included pregnant women enrolled at 26-29 weeks gestation who fully adhered to the prenatal supplement intervention for ≥8 consecutive weeks and for whom serum samples were available for D3 analysis (n=65). Serum D3 was uniformly low at enrolment. Mean D3 increased and was maximal at 1 day after vitamin D dose administration (152.09nmol/L, SD 25.11nmol/L) and remained significantly higher in VitD vs. Pl at 7 days (29.59nmol/L vs. 1.92nmol/L, p=0.007). Daily average of the group mean D3 during the week following dosing was 66.97nmol/L in VitD versus 2.13nmol/L in Pl. In conclusion, serum D3 remained significantly elevated throughout the week following ≥8 consecutive weekly doses of 35,000 IU D3 in pregnant women. However, the clinically significant minimum threshold of serum D3 remains to be established. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Patient-related factors determining geometry of intracavitary applicators and pelvic dose distribution during cervical cancer brachytherapy

    International Nuclear Information System (INIS)

    Senkus-Konefka, Elzbieta; Kobierska, Anna; Jassem, Jacek; Badzio, Andrezej

    1997-01-01

    Purpose: The aim of this study was to assess retrospectively the influence of the size of cervical cancer brachytherapy applicators (ovoids and uterine tandems) on pelvic dose distribution and to analyze the impact of various patient-and disease-related factors on applicators' geometry and on dose distribution in particular applications. Methods and Materials: The subject of this study were 356 cervical cancer patients treated with Selectron LDR as a part of their radical radiotherapy. Analyzed factors included patient age, weight, number of vaginal deliveries, and disease stage. Results: The use of larger vaginal applicators resulted in lower bladder and rectum doses and in higher point B doses (all p < 0.0001); longer uterine tandems produced lower rectum doses and higher point B doses (both p < 0.0001). Increasing patient age and disease stage resulted in a decreased frequency of use of large ovoids (both p < 0.0001) and of long tandems (age: p = 0.0069, stage: p = 0.004). As a result, higher doses to bladder (age: p < 0.0001, stage: p = 0.017) and rectum (age: p = 0.037, stage: p = 0.011) were observed. Increasing age also resulted in lower point B doses (p < 0.0001). Increasing patient weight correlated with less frequent use of long tandems (p = 0.0015) and with higher bladder doses (p = 0.04). Higher number of vaginal deliveries was related to the increase in the use of long tandems (p = 0.002); in patients who had had at least one vaginal delivery, point B doses were significantly higher (p = 0.0059). In multivariate analysis ovoid size and uterine tandem length were dependent on patient age (respectively: p < 0.001 and p = 0.001), disease stage (respectively: p = 0.003 and p = 0.008) and on the number of vaginal deliveries (respectively: p = 0.07 and p 0.008). Doses to critical organs and to points B were dependent on patient age (respectively: p < 0.001, p = 0.011, and p < 0.001) and on disease stage (respectively: p < 0.001, p = 0.004, and p = 0

  12. Results of comparative assessment of US and foreign nuclear power plant dose experience and dose reduction programs

    International Nuclear Information System (INIS)

    Baum, J.W.; Horan, J.R.; Dionne, B.J.

    1985-01-01

    The objectives of this study were to determine how collective dose equivalents at US nuclear power plants compare to those of other technically advanced countries, and to evaluate factors that contribute to the differences. Fifty Health Physicists and nuclear engineers from 10 countries met at BNL May 29 - June 1, 1984 to exchange information and hold discussions on ''Historical Dose Experience and Dose Reduction (ALARA) at Nuclear Power Plants''. Results of evaluation of data from this meeting and other data from recent publications are summarized. Based on data evaluated to date it is clear that US plants have higher collective dose equivalents per reactor and per MW-yr generated than most other countries. Factors which contribute to low doses include: 1) minimization of cobalt in primary system components exposed to water, 2) careful control of primary system oxygen and pH, 3) good primary system water purity to minimize corrosion product formation, 4) careful plant design, layout and component segregation and shielding, 5) management interest and commitment, 6) minimum number of workers and in-depth worker training, 7) use of special tools, and 8) plant standardization

  13. Haloperidol dose combined with dexamethasone for PONV prophylaxis in high-risk patients undergoing gynecological laparoscopic surgery: a prospective, randomized, double-blind, dose-response and placebo-controlled study.

    Science.gov (United States)

    Joo, Jin; Park, Yong Gyu; Baek, Jungwon; Moon, Young Eun

    2015-07-08

    Low-dose haloperidol is known to be effective for the prevention of postoperative nausea and vomiting (PONV). However, precise dose-response studies have not been completed, especially in patients at high risk for PONV who require combination therapy. This study sought to identify which dose of haloperidol 1mg or 2mg could be combined with dexamethasone without adverse effects in high-risk patients undergoing gynecological laparoscopic surgery. Female adults (n = 150) with three established PONV risk factors based on Apfel's score were randomized into one of three study groups. At the end of anesthesia, groups H0, H1, and H2 were given intravenous (IV) saline, haloperidol 1 mg, and haloperidol 2 mg, respectively. All patients were given dexamethasone 5 mg during the induction of anesthesia. The overall early (0-2 h) and late (2-24 h) incidences of nausea, vomiting, rescue anti-emetic administration, pain, and adverse effects (cardiac arrhythmias and extrapyramidal effects) were assessed postoperatively. The sedation score was recorded in the postanesthesia care unit (PACU). The total incidence of PONV over 24 h was significantly lower in groups H1 (29 %) and H2 (24 %) than in group H0 (54 %; P = 0.003), but there was no significant difference between groups H1 and H2. In the PACU, group H2 had a higher sedation score than groups H1 and H0 (P haloperidol was equally effective as 2 mg in terms of preventing PONV with the less sedative effect. ClinicalTrials.gov ( NCT01639599 ).

  14. Hardness, function, emotional well-being, satisfaction and the overall sexual experience in men using 100-mg fixed-dose or flexible-dose sildenafil citrate

    Science.gov (United States)

    Ströberg, P; Kaminetsky, J C; Park, N C; Goldfischer, E R; Creanga, D L; Stecher, V J

    2010-01-01

    The prescribing information for sildenafil citrate (VIAGRA, Pfizer, New York, NY, USA) recommends flexible dosing (50 mg initially, adjusted to 100 or 25 mg based on effectiveness and tolerability) in most men with erectile dysfunction (ED). In many men, however, 100 mg may be the most appropriate initial dose because it would reduce the need for titration and could prevent discouragement and treatment abandonment should 50 mg be insufficient. Results of two previously published double-blind, placebo-controlled sildenafil trials of similar design except for a fixed-dose vs flexible-dose regimen were analyzed. Relative to the flexible-dose, approximately one-third more men were satisfied with an initial and fixed dose of 100 mg. In addition, tolerability was similar, and improvements from baseline in outcomes on validated, ED-specific, patient-reported questionnaires were either similar (erectile function and the percentage of completely hard and fully rigid erections) or greater (emotional well-being and the overall sexual experience). The similarity in outcomes is not surprising given that almost 90% of the men in the flexible-dose trial titrated to 100 mg after 2 weeks. These data suggest prescription of an initial dose of 100 mg for men with ED, except in those for whom it is inappropriate. PMID:20596083

  15. Radiation oncology: what can we achieve by optimized dose delivery?

    International Nuclear Information System (INIS)

    Lawrence, T.

    2003-01-01

    Spectacular technical advances have marked the last twenty years in radiation oncology. This revolution began with CT-based planning which was followed by 3D conformal therapy. The latter approach produced two important capabilities. The most obvious was that tumors could be viewed in their true location with respect to normal tissues and treated with beams that were not in the axial plane. A second equally important advance was the development of 3D planning tools such as dose volume histograms. These tools permitted quantitative comparison of treatment plans and have supported the development of models relating normal tissue irradiation to the risk of complication. The '3D hypothesis' - that 3D treatment planning would permit higher doses of radiation to be safely delivered-has been proven. Dose escalation studies have been successfully conducted in the lung (= 100 Gy), liver (= 90 Gy), brain (= 90 Gy), and prostate (= 78 Gy). Prospective phase II and phase III trials suggest improved outcome using these higher doses for tumors in the liver and prostate compared to doses considered acceptable in the 2D era. The next technical revolution is underway, with advances in '4D' radiotherapy (accounting fully for organ motion) and in intensity-modulated radiation therapy (IMRT) to further improve the conformality and accuracy of treatment. Proton therapy will improve dose distributions still further. These improved dose distributions can be combined with more accurate tumor delineation provided by functional imaging to offer the potential for additional dose escalation without toxicity and for improved tumor control. These developments permit us to ask if we are approaching the limits of dose optimization and how (if?) research in radiation delivery should proceed

  16. Linear optical absorption response of poly(vinylidene fluoride - trifluoroethylene) copolymers to high gamma dose

    International Nuclear Information System (INIS)

    Medeiros, Adriana S.

    2009-01-01

    decrease in the size and crystalline order of the crystallites for increasing gamma doses. The copolymer becomes completely amorphous for dose higher than 1.0 MGy. The results of this investigation points out that the P(VDF-TrFE) copolymer is a good candidate for use in high dose gamma dosimetry applications for doses ranging from 0.1 to 750 kGy. (author)

  17. Effect of low doses of gamma radiation of Co-60 (radio-hormesis) in tomato seeds; Efeitos de baixas doses de radiacao gama do Co-60 (radio-hormesis) em sementes de tomate

    Energy Technology Data Exchange (ETDEWEB)

    Wiendl, Toni Andreas

    2010-07-01

    Tomato seeds of the Gladiador hybrid were exposed to gamma radiation of Co-60 with the following doses: 0; 2,5; 5; 7,5; 10; 12,5; 15 e 20 Gy. Analysis were performed on germination, seedlings height to cotyledon, seedling total height, seedling fresh and dry weight, plant height, stalk diameter at the root beginning, fresh and dry weight of the 5{sup th} leaf, number of green fruits with diameter higher than 3 cm, number of green, half ripen and ripen fruits, total number of fruits, Brix and pH of fruits, average fruit weight and fruit total production. A variety of stimulation effects were observed on the different plant developing stages. The greatest stimulus for production was observed in the 10 Gy dose. The highest seedling average height and plant average height were observed for the 7,5 Gy dose. The biggest number of green fruits with diameter higher than 3 cm occurred for the 12,5 and 15 Gy treatments. Irradiation also stimulated a higher total number of fruits in all doses, having advantage the 10 Gy dose which produced 88% more fruits than control as well as 86% more weight production. The fruits pH acidified significantly in a dose of 12,5 Gy and higher. Production increased in all treatments comparing to control and the highest stimulus for production observed was for the 10, 12,5 and 15 Gy. The use of low gamma radiation doses of Co-60 applied as pre-sowing treatment in the seeds, efficiently stimulated the development of plants and the tomato production. (author)

  18. Correlates of Human Papillomavirus (HPV) vaccination initiation and completion among 18-26 year olds in the United States.

    Science.gov (United States)

    Adjei Boakye, Eric; Lew, Daphne; Muthukrishnan, Meera; Tobo, Betelihem B; Rohde, Rebecca L; Varvares, Mark A; Osazuwa-Peters, Nosayaba

    2018-04-30

    To examine correlates of HPV vaccination uptake in a nationally representative sample of 18-26-year-old adults. Young adults aged 18-26 years were identified from the 2014 and 2015 National Health Interview Survey (n = 7588). Survey-weighted multivariable logistic regression models estimated sociodemographic factors associated with HPV vaccine initiation (≥1 dose) and completion (≥3 doses). Approximately 27% of study participants had initiated the HPV vaccine and 16% had completed the HPV vaccine. Participants were less likely to initiate the vaccine if they were men [(adjusted odds ratio) 0.19; (95% confidence interval) 0.16-0.23], had a high school diploma (0.40; 0.31-0.52) or less (0.46; 0.32-0.64) vs. college graduates, and were born outside the United States (0.52; 0.40-0.69). But, participants were more likely to initiate the HPV if they visited the doctor's office 1-5 times (2.09; 1.56-2.81), or ≥ 6 times (1.86; 1.48-2.34) within the last 12 months vs. no visits. Odds of completing HPV vaccine uptake followed the same pattern as initiation. And after stratifying the study population by gender and foreign-born status, these variables remained statistically significant. In our nationally representative study, only one out of six 18-26 year olds completed the required vaccine doses. Men, individuals with high school or less education, and those born outside the United States were less likely to initiate and complete the HPV vaccination. Our findings suggest that it may be useful to develop targeted interventions to promote HPV vaccination among those in the catch-up age range.

  19. Effective doses to family members of patients treated with radioiodine 131

    International Nuclear Information System (INIS)

    Kocovska, Marina Zdravevska; Ristevska, Svetlana Micevska; Nikolovski, Sasho; Jokic, Vesna Spasic

    2010-01-01

    The purpose of this study was to evaluate the effective dose to family members of thyroid cancer and hyperthyroid patients treated with radioiodine 131; also to compare the results with dose constraints proposed by International Commission of Radiological Protection (ICRP) and Basic Safety Standards (BSS) of the International Atomic Energy Agency (IAEA). Material and methods: for estimation of effective doses at sixty family members of thirty thyroid cancer and thirty hyperthyroid patients treated with radioiodine 131, the thermoluminescent dosimeters, Model TLD 100, were used. Thyroid cancer patients were hospitalized for three days, while hyperthyroid patients were treated on out-patient basis. The family members wore thermoluminescent dosimeter in front of the torso for seven days. Results: The radiation doses to family members of thyroid cancer patients were well below recommended dose constraint of 1 mSv. The mean value of effective dose was 0.21 mSv (min 0.02 - max 0.51 mSv). Effective doses, higher than 1 mSv, were detected at 11 family members of hyperthyroid patients.. The mean value of effective dose at family members of hyperthyroid patients was 0.87 mSv (min 0.12 - max 6.79) Conclusion: After three days of hospitalization and detailed given oral and written instruction, thyroid carcinoma patients maintain not to exceed the proposed dose limits. Hyperthyroid patients present a greater radiation hazard than thyroid carcinoma patients. The estimated effective doses were higher than the effective doses at family members of thyroid carcinoma patients. These findings may be considered when establishing new national guidelines concerning radiation protection and release of patients after a treatment with radioiodine therapy.(Author)

  20. Dose evaluation of TPS according to treatment sites in IMRT

    International Nuclear Information System (INIS)

    Kim, Jin Man; Kim, Jong Sik; Hong, Chae Seon; Park, Ju Young; Park, Su Yeon; Ju, Sang Gyu

    2013-01-01

    This study executed therapy plans on prostate cancer (homogeneous density area) and lung cancer (non-homogeneous density area) using radiation treatment planning systems such as Pinnacle 3 (version 9.2, Philips Medical Systems, USA) and Eclipse (version 10.0, Varian Medical Systems, USA) in order to quantify the difference between dose calculation according to density in IMRT. The subjects were prostate cancer patients (n=5) and lung cancer patients (n=5) who had therapies in our hospital. Identical constraints and optimization process according to the Protocol were administered on the subjects. For the therapy plan of prostate cancer patients, 10 MV and 7Beam were used and 2.5 Gy was prescribed in 28 fx to make 70 Gy in total. For lung cancer patients, 6 MV and 6Beam were used and 2 Gy was prescribed in 33 fx to make 66 Gy in total. Through two therapy planning systems, maximum dose, average dose, and minimum dose of OAR (Organ at Risk) of CTV, PTV and around tumor were investigated. In prostate cancer, both therapy planning systems showed within 2% change of dose of CTV and PTV and normal organs (Bladder, Both femur and Rectum out) near the tumor satisfied the dose constraints. In lung cancer, CTV and PTV showed less than 2% changes in dose and normal organs (Esophagus, Spinal cord and Both lungs) satisfied dose restrictions. However, the minimum dose of Eclipse therapy plan was 1.9% higher in CTV and 3.5% higher in PTV, and in case of both lungs there was 3.0% difference at V5 Gy. Each TPS according to the density satisfied dose limits of our hospital proving the clinical accuracy. It is considered more accurate and precise therapy plan can be made if studies on treatment planning for diverse parts and the application of such TPS are made