WorldWideScience

Sample records for higher detection limit

  1. Material limitations on the detection limit in refractometry.

    Science.gov (United States)

    Skafte-Pedersen, Peder; Nunes, Pedro S; Xiao, Sanshui; Mortensen, Niels Asger

    2009-01-01

    We discuss the detection limit for refractometric sensors relying on high-Q optical cavities and show that the ultimate classical detection limit is given by min {Δn} ≳ η, with n + iη being the complex refractive index of the material under refractometric investigation. Taking finite Q factors and filling fractions into account, the detection limit declines. As an example we discuss the fundamental limits of silicon-based high-Q resonators, such as photonic crystal resonators, for sensing in a bio-liquid environment, such as a water buffer. In the transparency window (λ ≳ 1100 nm) of silicon the detection limit becomes almost independent on the filling fraction, while in the visible, the detection limit depends strongly on the filling fraction because the silicon absorbs strongly.

  2. Material Limitations on the Detection Limit in Refractometry

    Directory of Open Access Journals (Sweden)

    Niels Asger Mortensen

    2009-10-01

    Full Text Available We discuss the detection limit for refractometric sensors relying on high-Q optical cavities and show that the ultimate classical detection limit is given by min {Δn} ≳ η with n + iη being the complex refractive index of the material under refractometric investigation. Taking finite Q factors and filling fractions into account, the detection limit declines. As an example we discuss the fundamental limits of silicon-based high-Q resonators, such as photonic crystal resonators, for sensing in a bio-liquid environment, such as a water buffer. In the transparency window (λ ≳ 1100 nm of silicon the detection limit becomes almost independent on the filling fraction, while in the visible, the detection limit depends strongly on the filling fraction because the silicon absorbs strongly.

  3. Determination of detection limits for a VPD ICPMS method of analysis; Determination des limites de detection d'une methode d'analyse VPD ICPMS

    Energy Technology Data Exchange (ETDEWEB)

    Badard, M.; Veillerot, M

    2007-07-01

    This training course report presents the different methods of detection and quantifying of metallic impurities in semiconductors. One of the most precise technique is the collection of metal impurities by vapor phase decomposition (VPD) followed by their analysis by ICPMS (inductively coupled plasma mass spectrometry). The study shows the importance of detection limits in the domain of chemical analysis and the way to determine them for the ICPMS analysis. The results found on detection limits are excellent. Even if the detection limits reached with ICPMS performed after manual or automatic VPD are much higher than detection limits of ICPMS alone, this method remains one of the most sensible for ultra-traces analysis. (J.S.)

  4. Material Limitations on the Detection Limit in Refractometry

    OpenAIRE

    Skafte-Pedersen, Peder; Nunes, Pedro S.; Xiao, Sanshui; Mortensen, Niels Asger

    2009-01-01

    We discuss the detection limit for refractometric sensors relying on high-Q optical cavities and show that the ultimate classical detection limit is given by min {Δn} ≳ η with n + iη being the complex refractive index of the material under refractometric investigation. Taking finite Q factors and filling fractions into account, the detection limit declines. As an example we discuss the fundamental limits of silicon-based high-Q resonators, such as photonic crystal resonators, for sensing in a...

  5. Determination of detection limits for a VPD ICPMS method of analysis

    International Nuclear Information System (INIS)

    Badard, M.; Veillerot, M.

    2007-01-01

    This training course report presents the different methods of detection and quantifying of metallic impurities in semiconductors. One of the most precise technique is the collection of metal impurities by vapor phase decomposition (VPD) followed by their analysis by ICPMS (inductively coupled plasma mass spectrometry). The study shows the importance of detection limits in the domain of chemical analysis and the way to determine them for the ICPMS analysis. The results found on detection limits are excellent. Even if the detection limits reached with ICPMS performed after manual or automatic VPD are much higher than detection limits of ICPMS alone, this method remains one of the most sensible for ultra-traces analysis. (J.S.)

  6. Material limitations on the detection limit in refractometry

    DEFF Research Database (Denmark)

    Skafte-Pedersen, Peder; Nunes, Pedro; Xiao, Sanshui

    2009-01-01

    We discuss the detection limit for refractometric sensors relying on high-Q optical cavities and show that the ultimate classical detection limit is given by min {Δn} ≳ η with n + iη being the complex refractive index of the material under refractometric investigation. Taking finite Q factors and...

  7. Confirmation of identity and detection limit in neutron activation analysis

    International Nuclear Information System (INIS)

    Yustina Tri Handayani; Slamet Wiyuniati; Tulisna

    2010-01-01

    Neutron Activation Analysis (NAA) based on neutron capture by nuclides. Of the various possibilities of radionuclides that occur, radionuclides and gamma radiation which provides the identity of the element were analyzed and the best sensitivity should be determined. Confirmation for elements in sediment samples was done theoretically and experimentally. The result of confirmation shows that Al, V, Cr K, Na, Ca and Zn were analyzed based on radionuclides of Al-28, V-52, Cr-51 , K-42, Na-24, Ca-48, Zn-65. Elements of Mg, Mn, Fe, Co were analyzed based on radionuclides of Mg-27, Mn-56, Fe-59, Co-60 through peak which the highest value of combined probability of radiation emission and efficiency. Cu can be analyzed through Cu-64 or Cu-66, but the second is more sensitive. Detection limit is determined at a certain measurement conditions carried out by a laboratory. Detection limit in the NAA is determined based on the Compton continue area by Curie method. The detection limit of Al, V, Ca, Mg, Mn, As, K, Na, Mg, Ce, Co, Cr, Fe, La, Sc, and Zn in sediment samples are 240, 27, 4750, 2600, 21, 3.3 , 75, 1.4, 1.8, 0.5, 2.7, 29, 1, 0.05, and 37 ppm. Analysis of Cu in sediments which concentrations of 98.6 ppm, Cu-66 is not detected. Tests using pure standard solutions of Cu obtained detection limit of 0.12 µg, or 7.9 ppm in samples of 15 mg. In general, the detection limit obtained was higher than the detection limit of the reference, it was caused by the differences in the sample matrix and analytical conditions. (author)

  8. Limits of detection and decision. Part 4

    International Nuclear Information System (INIS)

    Voigtman, E.

    2008-01-01

    Probability density functions (PDFs) have been derived for a number of commonly used limit of detection definitions, including several variants of the Relative Standard Deviation of the Background-Background Equivalent Concentration (RSDB-BEC) method, for a simple linear chemical measurement system (CMS) having homoscedastic, Gaussian measurement noise and using ordinary least squares (OLS) processing. All of these detection limit definitions serve as both decision and detection limits, thereby implicitly resulting in 50% rates of Type 2 errors. It has been demonstrated that these are closely related to Currie decision limits, if the coverage factor, k, is properly defined, and that all of the PDFs are scaled reciprocals of noncentral t variates. All of the detection limits have well-defined upper and lower limits, thereby resulting in finite moments and confidence limits, and the problem of estimating the noncentrality parameter has been addressed. As in Parts 1-3, extensive Monte Carlo simulations were performed and all the simulation results were found to be in excellent agreement with the derived theoretical expressions. Specific recommendations for harmonization of detection limit methodology have also been made

  9. Practical low dose limits for passive personal dosemeters and the implications for uncertainties close to the limit of detection

    International Nuclear Information System (INIS)

    Gilvin, P. J.; Perks, C. A.

    2011-01-01

    Recent years have seen the increasing use of passive dosemeters that have high sensitivities and, in laboratory conditions, detection limits of <10 μSv. However, in real operational use the detection limits will be markedly higher, because a large fraction of the accrued dose will be due to natural background, and this must be subtracted in order to obtain the desired occupational dose. No matter how well known the natural background is, the measurement uncertainty on doses of a few tens of microsieverts will be large. Individual monitoring services need to recognise this and manage the expectations of their clients by providing sufficient information. (authors)

  10. Detection limit calculations for different total reflection techniques

    International Nuclear Information System (INIS)

    Sanchez, H.J.

    2000-01-01

    In this work, theoretical calculations of detection limits for different total-reflection techniques are presented.. Calculations include grazing incidence (TXRF) and gracing exit (GEXRF) conditions. These calculations are compared with detection limits obtained for conventional x-ray fluorescence (XRF). In order to compute detection limits the Shiraiwa and Fujino's model to calculate x-ray fluorescence intensities was used. This model made certain assumptions and approximations to achieve the calculations, specially in the case of the geometrical conditions of the sample, and the incident and takeoff beams. Nevertheless the calculated data of detection limits for conventional XRF and total-reflection XRF show a good agreement with previous results. The model proposed here allows to analyze the different sources of background and the influence of the excitation geometry, which contribute to the understanding of the physical processes involved in the XRF analysis by total reflection. Finally, a comparison between detection limits in total-reflection analysis at grazing incidence and at grazing exit is carried out. Here a good agreement with the theoretical predictions of the reversibility principle is found, showing that detection limits are similar for both techniques. (author)

  11. Activation analysis. Detection limits

    International Nuclear Information System (INIS)

    Revel, G.

    1999-01-01

    Numerical data and limits of detection related to the four irradiation modes, often used in activation analysis (reactor neutrons, 14 MeV neutrons, photon gamma and charged particles) are presented here. The technical presentation of the activation analysis is detailed in the paper P 2565 of Techniques de l'Ingenieur. (A.L.B.)

  12. APPLYING MARKETING TO HIGHER EDUCATION: SCOPE AND LIMITS

    OpenAIRE

    Luminiţa NICOLESCU

    2009-01-01

    This paper focuses on applying marketing concepts to the higher education sector. It starts by shortly reviewing some of the main marketing concepts and continues with an overview of how such marketing concepts can be relevantly used for the higher education sector. The extent and limits in their application are identified and dicussed and the paper also suggests which of the marketing ideas are already highly used in higher education and which ones still have to be developed.

  13. Establishment of limits of detection and decision

    International Nuclear Information System (INIS)

    Mende, O.; Michel, R.

    1995-01-01

    The purpose of this project was to develop and test procedures to establish limits of decision and detection for spectrometric nuclear radiation measurements. Beside the determination of the limits of application of DIN 25482 part 2 and 5 - both primarily suitable for high resoluted spectra areas -the statistical model was expanded in such a way that henceforth blanks and influences of sample treatment can also be taken into account; the corresponding procedures to calculate the limits of decision and detection have a high precision. Additional procedures of calculation were developed to take the special characteristics of the analysis of complex spectra areas into account. (orig.) [de

  14. Working with Detection Limits in X-Ray and Nuclear Spectrometry

    International Nuclear Information System (INIS)

    Van Espen, P.

    2003-01-01

    Full Text: Detection limits are important in many measurement procedures. Especially in analytical work we often need to take a decision about the presence or absence of a compound, or we need to guarantee that or instrument can detect the compound. Especially in regulatory work the concept of detection limits plays a crucial role. Data acquisition in x-ray and gamma-ray spectrometry is done by counting events for a preset time; hence the fluctuations in the observed spectra are governed by Poisson (counting) statistics. This makes the calculation of detection limits in principle very easy. However it is observed that there exists a great deal of confusion concerning the definition(s) and especially concerning the practical calculation and reporting of detection limits. In this contribution a simple but rigorous treatment of the concept of detection limits will be given, emphasizing on aspects such as a-priori and a-posterior i limits and on the effect of sample blank and instrumental blank in the calculation of the true detection limit. The problem of near zero background as observed in e.g. total reflection x-ray fluorescence analysis (T-XRF) and some low level counting applications will also be discussed. In this case Poisson statistics might not be applicable, affecting the decision limits with respect to the presence of absence of a signal. Finally handling data sets that contain detection limit values next to normal measured values, the so called problem of missing data will be discussed. Some suggestions to deal with this frequently occurring situation will be given

  15. Limits of qualitative detection and quantitative determination

    International Nuclear Information System (INIS)

    Curie, L.A.

    1976-01-01

    The fact that one can find a series of disagreeing and limiting definitions of the detection limit leads to the reinvestigation of the problems of signal detection and signal processing in analytical and nuclear chemistry. Three cut-off levels were fixed: Lsub(C) - the net signal level (sensitivity of the equipment), above which an observed signal can be reliably recognized as 'detected'; Lsub(D) - the 'true' net signal level, from which one can a priori expect a detection; Lsub(Q) - the level at which the measuring accuracy is sufficient for quantitative determination. Exact definition equations as well as a series of working formulae are given for the general analytical case and for the investigation of radioactivity. As it is assumed that the radioactivity of the Poisson distribution is determined, it is dealt with in such a manner that precise limits can be derived for short-lived and long-lived radionuclides with or without disturbance. The fundamentals are made clear by simple examples for spectrophotometry and radioactivity and by a complicated example for activation analysis in which one must choose between alternative nuclear reactions. (orig./LH) [de

  16. On the lower of limit detection of radiometric systems

    International Nuclear Information System (INIS)

    Kamburov, H.; Boneva, S.

    1983-01-01

    The existing definitions of the quantity Asub(min), the lower detection limit, introduced as a characteristic of the sensitivity of radiometric systems are reviewed. A convenient way is found for comparing the different definitions by showing that each definition is connected with a specific value of the probability a of Type I error. The detection limits are calculated for a normal and Poisson distributions of the measured quantities. A criterion is proposed for the applicability of the normal distiribution to the problem of determining the lower detection limit

  17. Limits of Tumor Detectability in Nuclear Medicine and PET

    Directory of Open Access Journals (Sweden)

    Yusuf Emre Erdi

    2012-04-01

    Full Text Available Objective: Nuclear medicine is becoming increasingly important in the early detection of malignancy. The advantage of nuclear medicine over other imaging modalities is the high sensitivity of the gamma camera. Nuclear medicine counting equipment has the capability of detecting levels of radioactivity which exceed background levels by as little as 2.4 to 1. This translates to only a few hundred counts per minute on a regular gamma camera or as few as 3 counts per minute when using coincidence detection on a positron emission tomography (PET camera. Material and Methods: We have experimentally measured the limits of detectability using a set of hollow spheres in a Jaszczak phantom at various tumor-to-background ratios. Imaging modalities for this work were (1 planar, (2 SPECT, (3 PET, and (4 planar camera with coincidence detection capability (MCD. Results: When there is no background (infinite contrast activity present, the detectability of tumors is similar for PET and planar imaging. With the presence of the background activity , PET can detect objects in an order of magnitude smaller in size than that can be seen by conventional planar imaging especially in the typical clinical low (3:1 T/B ratios. The detection capability of the MCD camera lies between a conventional nuclear medicine (planar / SPECT scans and the detection capability of a dedicated PET scanner Conclusion: Among nuclear medicine’s armamentarium, PET is the closest modality to CT or MR imaging in terms of limits of detection. Modern clinical PET scanners have a resolution limit of 4 mm, corresponding to the detection of tumors with a volume of 0.2 ml (7 mm diameter in 5:1 T/B ratio. It is also possible to obtain better resolution limits with dedicated brain and animal scanners. The future holds promise in development of new detector materials, improved camera design, and new reconstruction algorithms which will improve sensitivity, resolution, contrast, and thereby further

  18. Method to Solve the Problem of the Radioactivity Detection in Environmental Samples. Characteristic Limits

    International Nuclear Information System (INIS)

    Gasco, C.; Martinez, M.; Heras, M.

    2009-01-01

    The problem of the detection or when the radioactivity can be considered as higher than the background using different measurement techniques has been the objective of several statistical studies and controversies. The detection limit and the critical limit were studied by Currie in year 1968 and used by radiochemistry laboratories considering different ways of calculation that introduced confusion and not correct implementations. In the last few years, and due to the increasing number of standardization processes on the field of radioactivity and accreditation, several international institutions have chosen to unify the criteria for using common determination of detection limits. The most used methods are those developed by MARLAP and International Standard Organization ISO (Standard-11929). In this report are summarised both standards doing a comparative study and giving some examples of how to apply these limits. In same cases, little differences in the uncertainty calculation have been observed but the final results have been concordant. A deeply study of these standards can be done consulting the web page of the American Labs that developed MARLAP or buying the original ISO standard ISO-11929 recently approved (2009). (Author) 17 refs

  19. Search times and probability of detection in time-limited search

    Science.gov (United States)

    Wilson, David; Devitt, Nicole; Maurer, Tana

    2005-05-01

    When modeling the search and target acquisition process, probability of detection as a function of time is important to war games and physical entity simulations. Recent US Army RDECOM CERDEC Night Vision and Electronics Sensor Directorate modeling of search and detection has focused on time-limited search. Developing the relationship between detection probability and time of search as a differential equation is explored. One of the parameters in the current formula for probability of detection in time-limited search corresponds to the mean time to detect in time-unlimited search. However, the mean time to detect in time-limited search is shorter than the mean time to detect in time-unlimited search and the relationship between them is a mathematical relationship between these two mean times. This simple relationship is derived.

  20. Higher-order harmonics of general limited diffraction Bessel beams

    International Nuclear Information System (INIS)

    Ding De-Sheng; Huang Jin-Huang

    2016-01-01

    In this paper, we extensively study the higher-order harmonic generation of the general limited diffraction m -th-order Bessel beam. The analysis is based on successive approximations of the Khokhlov–Zabolotskaya–Kuznetsov (KZK) equation. Asymptotic expansions are presented for higher-order harmonic Bessel beams in near and far fields. The validity of asymptotic approximation is also analyzed. The higher-order harmonic of the Bessel beam with the lowest zero-order is taken as a special example. (special topic)

  1. Methodologies for the practical determination and use of method detection limits

    International Nuclear Information System (INIS)

    Rucker, T.L.

    1995-01-01

    Method detection limits have often been misunderstood and misused. The basic definitions developed by Lloyd Currie and others have been combined with assumptions that are inappropriate for many types of radiochemical analyses. A partical way for determining detection limits based on Currie's basic definition is presented that removes the reliance on assumptions and that accounts for the total measurement uncertainty. Examples of proper and improper use of detection limits are also presented, including detection limits reported by commercial software for gamma spectroscopy and neutron activation analyses. (author) 6 refs.; 2 figs

  2. No evidence for an item limit in change detection.

    Directory of Open Access Journals (Sweden)

    Shaiyan Keshvari

    Full Text Available Change detection is a classic paradigm that has been used for decades to argue that working memory can hold no more than a fixed number of items ("item-limit models". Recent findings force us to consider the alternative view that working memory is limited by the precision in stimulus encoding, with mean precision decreasing with increasing set size ("continuous-resource models". Most previous studies that used the change detection paradigm have ignored effects of limited encoding precision by using highly discriminable stimuli and only large changes. We conducted two change detection experiments (orientation and color in which change magnitudes were drawn from a wide range, including small changes. In a rigorous comparison of five models, we found no evidence of an item limit. Instead, human change detection performance was best explained by a continuous-resource model in which encoding precision is variable across items and trials even at a given set size. This model accounts for comparison errors in a principled, probabilistic manner. Our findings sharply challenge the theoretical basis for most neural studies of working memory capacity.

  3. Importance of the lower limit of detection in radiological safety

    International Nuclear Information System (INIS)

    Rafael Terol T.; Hermenegildo Maldonado M.

    1991-01-01

    The concept of the Lower Limit of Detection (LLD) it contributes in the solution of some problems related with the radiological safety, such as the realization of the tests of flight of the sealed radioactive sources; the determination of radioisotopes in environmental samples; the estimate of present radionuclides in polluted foods; in general, the detection of small quantities of radioactive materials present in materials of use or consumption by part of the man in his daily life; as the one Lower Limit of Detection is related with topics of statistics, in this work a small review of them is made, it was superficially discussed the mensuration problems related with the establishment of the Lower Limit of Detection

  4. Higher-Order Cyclostationarity Detection for Spectrum Sensing

    Directory of Open Access Journals (Sweden)

    Julien Renard

    2010-01-01

    Full Text Available Recent years have shown a growing interest in the concept of Cognitive Radios (CRs, able to access portions of the electromagnetic spectrum in an opportunistic operating way. Such systems require efficient detectors able to work in low Signal-to-Noise Ratio (SNR environments, with little or no information about the signals they are trying to detect. Energy detectors are widely used to perform such blind detection tasks, but quickly reach the so-called SNR wall below which detection becomes impossible Tandra (2005. Cyclostationarity detectors are an interesting alternative to energy detectors, as they exploit hidden periodicities present in man-made signals, but absent in noise. Such detectors use quadratic transformations of the signals to extract the hidden sine-waves. While most of the literature focuses on the second-order transformations of the signals, we investigate the potential of higher-order transformations of the signals. Using the theory of Higher-Order Cyclostationarity (HOCS, we derive a fourth-order detector that performs similarly to the second-order ones to detect linearly modulated signals, at SNR around 0 dB, which may be used if the signals of interest do not exhibit second-order cyclostationarity. More generally this paper reviews the relevant aspects of the cyclostationary and HOCS theory, and shows their potential for spectrum sensing.

  5. Higher-order harmonics of general limited diffraction Bessel beams

    Science.gov (United States)

    Ding, De-Sheng; Huang, Jin-Huang

    2016-12-01

    In this paper, we extensively study the higher-order harmonic generation of the general limited diffraction m-th-order Bessel beam. The analysis is based on successive approximations of the Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation. Asymptotic expansions are presented for higher-order harmonic Bessel beams in near and far fields. The validity of asymptotic approximation is also analyzed. The higher-order harmonic of the Bessel beam with the lowest zero-order is taken as a special example. Project supported by the National Natural Science Foundation of China (Grant Nos. 11074038 and 11374051).

  6. Gravitational wave detection using laser interferometry beyond the standard quantum limit

    Science.gov (United States)

    Heurs, M.

    2018-05-01

    Interferometric gravitational wave detectors (such as advanced LIGO) employ high-power solid-state lasers to maximize their detection sensitivity and hence their reach into the universe. These sophisticated light sources are ultra-stabilized with regard to output power, emission frequency and beam geometry; this is crucial to obtain low detector noise. However, even when all laser noise is reduced as far as technically possible, unavoidable quantum noise of the laser still remains. This is a consequence of the Heisenberg Uncertainty Principle, the basis of quantum mechanics: in this case, it is fundamentally impossible to simultaneously reduce both the phase noise and the amplitude noise of a laser to arbitrarily low levels. This fact manifests in the detector noise budget as two distinct noise sources-photon shot noise and quantum radiation pressure noise-which together form a lower boundary for current-day gravitational wave detector sensitivities, the standard quantum limit of interferometry. To overcome this limit, various techniques are being proposed, among them different uses of non-classical light and alternative interferometer topologies. This article explains how quantum noise enters and manifests in an interferometric gravitational wave detector, and gives an overview of some of the schemes proposed to overcome this seemingly fundamental limitation, all aimed at the goal of higher gravitational wave event detection rates. This article is part of a discussion meeting issue `The promises of gravitational-wave astronomy'.

  7. Stochastic fluctuations and the detectability limit of network communities.

    Science.gov (United States)

    Floretta, Lucio; Liechti, Jonas; Flammini, Alessandro; De Los Rios, Paolo

    2013-12-01

    We have analyzed the detectability limits of network communities in the framework of the popular Girvan and Newman benchmark. By carefully taking into account the inevitable stochastic fluctuations that affect the construction of each and every instance of the benchmark, we come to the conclusion that the native, putative partition of the network is completely lost even before the in-degree/out-degree ratio becomes equal to that of a structureless Erdös-Rényi network. We develop a simple iterative scheme, analytically well described by an infinite branching process, to provide an estimate of the true detectability limit. Using various algorithms based on modularity optimization, we show that all of them behave (semiquantitatively) in the same way, with the same functional form of the detectability threshold as a function of the network parameters. Because the same behavior has also been found by further modularity-optimization methods and for methods based on different heuristics implementations, we conclude that indeed a correct definition of the detectability limit must take into account the stochastic fluctuations of the network construction.

  8. Pushing the limits of NAA. Accuracy, uncertainty and detection limits

    International Nuclear Information System (INIS)

    Greenberg, R.R.

    2008-01-01

    This paper describes some highlights from the author's efforts to improve neutron activation analysis (NAA) detection limits through development and optimization of radiochemical separations, as well as to improve the overall accuracy of NAA measurements by identifying, quantifying and reducing measurement biases and uncertainties. Efforts to demonstrate the metrological basis of NAA, and to establish it as a 'Primary Method of Measurement' will be discussed. (author)

  9. Wavelet-based higher-order neural networks for mine detection in thermal IR imagery

    Science.gov (United States)

    Baertlein, Brian A.; Liao, Wen-Jiao

    2000-08-01

    An image processing technique is described for the detection of miens in RI imagery. The proposed technique is based on a third-order neural network, which processes the output of a wavelet packet transform. The technique is inherently invariant to changes in signature position, rotation and scaling. The well-known memory limitations that arise with higher-order neural networks are addressed by (1) the data compression capabilities of wavelet packets, (2) protections of the image data into a space of similar triangles, and (3) quantization of that 'triangle space'. Using these techniques, image chips of size 28 by 28, which would require 0(109) neural net weights, are processed by a network having 0(102) weights. ROC curves are presented for mine detection in real and simulated imagery.

  10. What value, detection limits

    International Nuclear Information System (INIS)

    Currie, L.A.

    1986-01-01

    Specific approaches and applications of LLD's to nuclear and ''nuclear-related'' measurements are presented in connection with work undertaken for the U.S. Nuclear Regulatory Commission and the International Atomic Energy Agency. In this work, special attention was given to assumptions and potential error sources, as well as to different types of analysis. For the former, the authors considered random and systematic error associated with the blank and the calibration and sample preparation processes, as well as issues relating to the nature of the random error distributions. Analysis types considered included continuous monitoring, ''simple counting'' involving scalar quantities, and spectrum fitting involving data vectors. The investigation of data matrices and multivariate analysis is also described. The most important conclusions derived from this study are: that there is a significant lack of communication and compatibility resulting from diverse terminology and conceptual bases - including no-basis ''ad hoc'' definitions; that the distinction between detection decisions and detection limits is frequently lost sight of; and that quite erroneous LOD estimates follow from inadequate consideration of the actual variability of the blank, and systematic error associated with the blank, the calibration-recovery factor, matrix effects, and ''black box'' data reduction models

  11. The limit of detection for explosives in spectroscopic differential reflectometry

    Science.gov (United States)

    Dubroca, Thierry; Vishwanathan, Karthik; Hummel, Rolf E.

    2011-05-01

    In the wake of recent terrorist attacks, such as the 2008 Mumbai hotel explosion or the December 25th 2009 "underwear bomber", our group has developed a technique (US patent #7368292) to apply differential reflection spectroscopy to detect traces of explosives. Briefly, light (200-500 nm) is shone on a surface such as a piece of luggage at an airport. Upon reflection, the light is collected with a spectrometer combined with a CCD camera. A computer processes the data and produces in turn a differential reflection spectrum involving two adjacent areas of the surface. This differential technique is highly sensitive and provides spectroscopic data of explosives. As an example, 2,4,6, trinitrotoluene (TNT) displays strong and distinct features in differential reflectograms near 420 nm. Similar, but distinctly different features are observed for other explosives. One of the most important criteria for explosive detection techniques is the limit of detection. This limit is defined as the amount of explosive material necessary to produce a signal to noise ratio of three. We present here, a method to evaluate the limit of detection of our technique. Finally, we present our sample preparation method and experimental set-up specifically developed to measure the limit of detection for our technology. This results in a limit ranging from 100 nano-grams to 50 micro-grams depending on the method and the set-up parameters used, such as the detector-sample distance.

  12. Detection of colloidal silver chloride near solubility limit

    Science.gov (United States)

    Putri, K. Y.; Adawiah, R.

    2018-03-01

    Detection of nanoparticles in solution has been made possible by several means; one of them is laser-induced breakdown detection (LIBD). LIBD is able to distinguish colloids of various sizes and concentrations. This technique has been used in several solubility studies. In this study, the formation of colloids in a mixed system of silver nitrate and sodium chloride was observed by acoustic LIBD. Silver chloride has low solubility limit, therefore LIBD measurement is appropriate. Silver and chloride solutions with equal concentrations, set at below and above the solubility of silver chloride as the expected solid product, were mixed and the resulting colloids were observed. The result of LIBD measurement showed that larger particles were present as more silver and chloride introduced. However, once the concentrations exceeded the solubility limit of silver chloride, the detected particle size seemed to be decreasing, hence suggested the occurrence of coprecipitation process. This phenomenon indicated that the ability of LIBD to detect even small changes in colloid amounts might be a useful tool in study on formation and stability of colloids, i.e. to confirm whether nanoparticles synthesis has been successfully performed and whether the system is stable or not.

  13. South African legislation on limiting private and foreign higher ...

    African Journals Online (AJOL)

    A number of the amendments were aimed at limiting the operations of private and foreign higher education institutions in South Africa. Good arguments exist for the ... The article introduces a link to the concept of globalisation by indicating how global financial markets impact on developing countries. It then explores the ...

  14. Enhancement of laser-induced breakdown spectroscopy (LIBS) Detection limit using a low-pressure and short-pulse laser-induced plasma process.

    Science.gov (United States)

    Wang, Zhen Zhen; Deguchi, Yoshihiro; Kuwahara, Masakazu; Yan, Jun Jie; Liu, Ji Ping

    2013-11-01

    Laser-induced breakdown spectroscopy (LIBS) technology is an appealing technique compared with many other types of elemental analysis because of the fast response, high sensitivity, real-time, and noncontact features. One of the challenging targets of LIBS is the enhancement of the detection limit. In this study, the detection limit of gas-phase LIBS analysis has been improved by controlling the pressure and laser pulse width. In order to verify this method, low-pressure gas plasma was induced using nanosecond and picosecond lasers. The method was applied to the detection of Hg. The emission intensity ratio of the Hg atom to NO (IHg/INO) was analyzed to evaluate the LIBS detection limit because the NO emission (interference signal) was formed during the plasma generation and cooling process of N2 and O2 in the air. It was demonstrated that the enhancement of IHg/INO arose by decreasing the pressure to a few kilopascals, and the IHg/INO of the picosecond breakdown was always much higher than that of the nanosecond breakdown at low buffer gas pressure. Enhancement of IHg/INO increased more than 10 times at 700 Pa using picosecond laser with 35 ps pulse width. The detection limit was enhanced to 0.03 ppm (parts per million). We also saw that the spectra from the center and edge parts of plasma showed different features. Comparing the central spectra with the edge spectra, IHg/INO of the edge spectra was higher than that of the central spectra using the picosecond laser breakdown process.

  15. Impact of sensor detection limits on protecting water distribution systems from contamination events

    International Nuclear Information System (INIS)

    McKenna, Sean Andrew; Hart, David Blaine; Yarrington, Lane

    2006-01-01

    Real-time water quality sensors are becoming commonplace in water distribution systems. However, field deployable, contaminant-specific sensors are still in the development stage. As development proceeds, the necessary operating parameters of these sensors must be determined to protect consumers from accidental and malevolent contamination events. This objective can be quantified in several different ways including minimization of: the time necessary to detect a contamination event, the population exposed to contaminated water, the extent of the contamination within the network, and others. We examine the ability of a sensor set to meet these objectives as a function of both the detection limit of the sensors and the number of sensors in the network. A moderately sized distribution network is used as an example and different sized sets of randomly placed sensors are considered. For each combination of a certain number of sensors and a detection limit, the mean values of the different objectives across multiple random sensor placements are calculated. The tradeoff between the necessary detection limit in a sensor and the number of sensors is evaluated. Results show that for the example problem examined here, a sensor detection limit of 0.01 of the average source concentration is adequate for maximum protection. Detection of events is dependent on the detection limit of the sensors, but for those events that are detected, the values of the performance measures are not a function of the sensor detection limit. The results of replacing a single sensor in a network with a sensor having a much lower detection limit show that while this replacement can improve results, the majority of the additional events detected had performance measures of relatively low consequence.

  16. Censoring approach to the detection limits in X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Pajek, M.; Kubala-Kukus, A.

    2004-01-01

    We demonstrate that the effect of detection limits in the X-ray fluorescence analysis (XRF), which limits the determination of very low concentrations of trace elements and results in appearance of the so-called 'nondetects', can be accounted for using the statistical concept of censoring. More precisely, the results of such measurements can be viewed as the left random censored data, which can further be analyzed using the Kaplan-Meier method correcting the data for the presence of nondetects. Using this approach, the results of measured, detection limit censored concentrations can be interpreted in a nonparametric manner including the correction for the nondetects, i.e. the measurements in which the concentrations were found to be below the actual detection limits. Moreover, using the Monte Carlo simulation technique we show that by using the Kaplan-Meier approach the corrected mean concentrations for a population of the samples can be estimated within a few percent uncertainties with respect of the simulated, uncensored data. This practically means that the final uncertainties of estimated mean values are limited in fact by the number of studied samples and not by the correction procedure itself. The discussed random-left censoring approach was applied to analyze the XRF detection-limit-censored concentration measurements of trace elements in biomedical samples

  17. Importance of the lower limit of detection in radiological safety; Importancia del limite inferior de deteccion en seguridad radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Rafael, Terol T; Hermenegildo, Maldonado M [Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico)

    1991-07-01

    The concept of the Lower Limit of Detection (LLD) it contributes in the solution of some problems related with the radiological safety, such as the realization of the tests of flight of the sealed radioactive sources; the determination of radioisotopes in environmental samples; the estimate of present radionuclides in polluted foods; in general, the detection of small quantities of radioactive materials present in materials of use or consumption by part of the man in his daily life; as the one Lower Limit of Detection is related with topics of statistics, in this work a small review of them is made, it was superficially discussed the mensuration problems related with the establishment of the Lower Limit of Detection.

  18. Calculation of the detection limit in radiation measurements with systematic uncertainties

    International Nuclear Information System (INIS)

    Kirkpatrick, J.M.; Russ, W.; Venkataraman, R.; Young, B.M.

    2015-01-01

    The detection limit (L D ) or Minimum Detectable Activity (MDA) is an a priori evaluation of assay sensitivity intended to quantify the suitability of an instrument or measurement arrangement for the needs of a given application. Traditional approaches as pioneered by Currie rely on Gaussian approximations to yield simple, closed-form solutions, and neglect the effects of systematic uncertainties in the instrument calibration. These approximations are applicable over a wide range of applications, but are of limited use in low-count applications, when high confidence values are required, or when systematic uncertainties are significant. One proposed modification to the Currie formulation attempts account for systematic uncertainties within a Gaussian framework. We have previously shown that this approach results in an approximation formula that works best only for small values of the relative systematic uncertainty, for which the modification of Currie's method is the least necessary, and that it significantly overestimates the detection limit or gives infinite or otherwise non-physical results for larger systematic uncertainties where such a correction would be the most useful. We have developed an alternative approach for calculating detection limits based on realistic statistical modeling of the counting distributions which accurately represents statistical and systematic uncertainties. Instead of a closed form solution, numerical and iterative methods are used to evaluate the result. Accurate detection limits can be obtained by this method for the general case

  19. Direct Detection Electron Energy-Loss Spectroscopy: A Method to Push the Limits of Resolution and Sensitivity.

    Science.gov (United States)

    Hart, James L; Lang, Andrew C; Leff, Asher C; Longo, Paolo; Trevor, Colin; Twesten, Ray D; Taheri, Mitra L

    2017-08-15

    In many cases, electron counting with direct detection sensors offers improved resolution, lower noise, and higher pixel density compared to conventional, indirect detection sensors for electron microscopy applications. Direct detection technology has previously been utilized, with great success, for imaging and diffraction, but potential advantages for spectroscopy remain unexplored. Here we compare the performance of a direct detection sensor operated in counting mode and an indirect detection sensor (scintillator/fiber-optic/CCD) for electron energy-loss spectroscopy. Clear improvements in measured detective quantum efficiency and combined energy resolution/energy field-of-view are offered by counting mode direct detection, showing promise for efficient spectrum imaging, low-dose mapping of beam-sensitive specimens, trace element analysis, and time-resolved spectroscopy. Despite the limited counting rate imposed by the readout electronics, we show that both core-loss and low-loss spectral acquisition are practical. These developments will benefit biologists, chemists, physicists, and materials scientists alike.

  20. Detection limits of antimicrobials in ewe milk by delvotest photometric measurements.

    Science.gov (United States)

    Althaus, R L; Torres, A; Montero, A; Balasch, S; Molina, M P

    2003-02-01

    The Delvotest method detection limits per manufacturer's instructions at a fixed reading time of 3 h for 24 antimicrobial agents were determined in ewe milk by photometric measurement. For each drug, eight concentrations were tested on 20 ewe milk samples from individual ewes. Detection limits, determined by means of logistic regression models, were (microg/kg): 3, amoxycillin; 2, ampicillin; 18, cloxacillin; 1, penicillin "G"; 34, cefadroxil; 430, cephalosporin "C"; 40, cephalexin; 20, cefoperazone; 33, Ceftiofur; 18, cefuroxime; 6100, streptomycin; 1200, gentamycin; 2600, neomycin; 830, erythromycin; 100, tylosin; 180, doxycycline; 320, oxytetracycline; 590, tetracycline; 88, sulfadiazine; 44, sulfamethoxazole; 140, sulfametoxypyridazine; 48, sulfaquinoxaline; 12,000, chloramphenicol; and 290, trimethoprim. Whereas the beta-lactam antibiotics, sulphonamides, and tylosin were detected by Delvotest method at levels equal to those of maximum residue limits, its sensitivity needs to be enhanced to detect aminoglycosides, tetracyclines, streptomycin, chloramphenicol, and trimethoprim residues in ewe milk or to develop an integrated residue detection system for ewe milk with different sensitive microorganisms for each group of antiinfectious agents.

  1. Limiter discriminator detection of M-ary FSK signals

    Science.gov (United States)

    Fonseka, John P.

    1990-10-01

    The performance of limiter discriminator detection of M-ary FSK signals is analyzed at arbitrary modulation indices. It is shown that the error rate performance of limiter discriminator detection can be significantly improved by increasing the modulation index above 1/M. The optimum modulation index that minimizes the overall error probability is determined for the cases M = 2, 4 and 8. The analysis is carried out for wideband and bandlimited channels with Gaussian and second-order Butterworth filters. It is shown that the optimum modulation index depends on the signal/noise ratio (SNR), in a wideband channel, and on both SNR and time-bandwidth product in a bandlimited channel. Finally, it is shown that the optimum sampling instance in presence of a nonzero phase IF filter can be approximately determined by using only the worst case symbol pattern.

  2. Realistic limitations of detecting planets around young active stars

    Directory of Open Access Journals (Sweden)

    Pinfield D.

    2013-04-01

    Full Text Available Current planet hunting methods using the radial velocity method are limited to observing middle-aged main-sequence stars where the signatures of stellar activity are much less than on young stars that have just arrived on the main-sequence. In this work we apply our knowledge from the surface imaging of these young stars to place realistic limitations on the possibility of detecting orbiting planets. In general we find that the magnitude of the stellar jitter is directly proportional to the stellar vsini. For G and K dwarfs, we find that it is possible, for models with high stellar activity and low stellar vsini, to be able to detect a 1 MJupiter mass planet within 50 epochs of observations and for the M dwarfs it is possible to detect a habitable zone Earth-like planet in 10s of observational epochs.

  3. Correction to the count-rate detection limit and sample/blank time-allocation methods

    International Nuclear Information System (INIS)

    Alvarez, Joseph L.

    2013-01-01

    A common form of count-rate detection limits contains a propagation of uncertainty error. This error originated in methods to minimize uncertainty in the subtraction of the blank counts from the gross sample counts by allocation of blank and sample counting times. Correct uncertainty propagation showed that the time allocation equations have no solution. This publication presents the correct form of count-rate detection limits. -- Highlights: •The paper demonstrated a proper method of propagating uncertainty of count rate differences. •The standard count-rate detection limits were in error. •Count-time allocation methods for minimum uncertainty were in error. •The paper presented the correct form of the count-rate detection limit. •The paper discussed the confusion between count-rate uncertainty and count uncertainty

  4. Theoretical detection limit of PIXE analysis using 20 MeV proton beams

    Science.gov (United States)

    Ishii, Keizo; Hitomi, Keitaro

    2018-02-01

    Particle-induced X-ray emission (PIXE) analysis is usually performed using proton beams with energies in the range 2∼3 MeV because at these energies, the detection limit is low. The detection limit of PIXE analysis depends on the X-ray production cross-section, the continuous background of the PIXE spectrum and the experimental parameters such as the beam currents and the solid angle and detector efficiency of X-ray detector. Though the continuous background increases as the projectile energy increases, the cross-section of the X-ray increases as well. Therefore, the detection limit of high energy proton PIXE is not expected to increase significantly. We calculated the cross sections of continuous X-rays produced in several bremsstrahlung processes and estimated the detection limit of a 20 MeV proton PIXE analysis by modelling the Compton tail of the γ-rays produced in the nuclear reactions, and the escape effect on the secondary electron bremsstrahlung. We found that the Compton tail does not affect the detection limit when a thin X-ray detector is used, but the secondary electron bremsstrahlung escape effect does have an impact. We also confirmed that the detection limit of the PIXE analysis, when used with 4 μm polyethylene backing film and an integrated beam current of 1 μC, is 0.4∼2.0 ppm for proton energies in the range 10∼30 MeV and elements with Z = 16-90. This result demonstrates the usefulness of several 10 MeV cyclotrons for performing PIXE analysis. Cyclotrons with these properties are currently installed in positron emission tomography (PET) centers.

  5. Method to Solve the Problem of the Radioactivity Detection in Environmental Samples. Characteristic Limits; Metodos para la Resolucion del Problema de la Detecfcion de Radiactividad en Muestras Ambientales. Limites Caracteristicos

    Energy Technology Data Exchange (ETDEWEB)

    Gasco, C.; Martinez, M.; Heras, M.

    2009-07-21

    The problem of the detection or when the radioactivity can be considered as higher than the background using different measurement techniques has been the objective of several statistical studies and controversies. The detection limit and the critical limit were studied by Currie in year 1968 and used by radiochemistry laboratories considering different ways of calculation that introduced confusion and not correct implementations. In the last few years, and due to the increasing number of standardization processes on the field of radioactivity and accreditation, several international institutions have chosen to unify the criteria for using common determination of detection limits. The most used methods are those developed by MARLAP and International Standard Organization ISO (Standard-11929). In this report are summarised both standards doing a comparative study and giving some examples of how to apply these limits. In same cases, little differences in the uncertainty calculation have been observed but the final results have been concordant. A deeply study of these standards can be done consulting the web page of the American Labs that developed MARLAP or buying the original ISO standard ISO-11929 recently approved (2009). (Author) 17 refs.

  6. Censoring: a new approach for detection limits in total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Pajek, M.; Kubala-Kukus, A.; Braziewicz, J.

    2004-01-01

    It is shown that the detection limits in the total-reflection X-ray fluorescence (TXRF), which restrict quantification of very low concentrations of trace elements in the samples, can be accounted for using the statistical concept of censoring. We demonstrate that the incomplete TXRF measurements containing the so-called 'nondetects', i.e. the non-measured concentrations falling below the detection limits and represented by the estimated detection limit values, can be viewed as the left random-censored data, which can be further analyzed using the Kaplan-Meier (KM) method correcting for nondetects. Within this approach, which uses the Kaplan-Meier product-limit estimator to obtain the cumulative distribution function corrected for the nondetects, the mean value and median of the detection limit censored concentrations can be estimated in a non-parametric way. The Monte Carlo simulations performed show that the Kaplan-Meier approach yields highly accurate estimates for the mean and median concentrations, being within a few percent with respect to the simulated, uncensored data. This means that the uncertainties of KM estimated mean value and median are limited in fact only by the number of studied samples and not by the applied correction procedure for nondetects itself. On the other hand, it is observed that, in case when the concentration of a given element is not measured in all the samples, simple approaches to estimate a mean concentration value from the data yield erroneous, systematically biased results. The discussed random-left censoring approach was applied to analyze the TXRF detection-limit-censored concentration measurements of trace elements in biomedical samples. We emphasize that the Kaplan-Meier approach allows one to estimate the mean concentrations being substantially below the mean level of detection limits. Consequently, this approach gives a new access to lower the effective detection limits for TXRF method, which is of prime interest for

  7. Accuracy, precision, and lower detection limits (a deficit reduction approach)

    International Nuclear Information System (INIS)

    Bishop, C.T.

    1993-01-01

    The evaluation of the accuracy, precision and lower detection limits of the determination of trace radionuclides in environmental samples can become quite sophisticated and time consuming. This in turn could add significant cost to the analyses being performed. In the present method, a open-quotes deficit reduction approachclose quotes has been taken to keep costs low, but at the same time provide defensible data. In order to measure the accuracy of a particular method, reference samples are measured over the time period that the actual samples are being analyzed. Using a Lotus spreadsheet, data are compiled and an average accuracy is computed. If pairs of reference samples are analyzed, then precision can also be evaluated from the duplicate data sets. The standard deviation can be calculated if the reference concentrations of the duplicates are all in the same general range. Laboratory blanks are used to estimate the lower detection limits. The lower detection limit is calculated as 4.65 times the standard deviation of a set of blank determinations made over a given period of time. A Lotus spreadsheet is again used to compile data and LDLs over different periods of time can be compared

  8. Prediction of the limit of detection of an optical resonant reflection biosensor.

    Science.gov (United States)

    Hong, Jongcheol; Kim, Kyung-Hyun; Shin, Jae-Heon; Huh, Chul; Sung, Gun Yong

    2007-07-09

    A prediction of the limit of detection of an optical resonant reflection biosensor is presented. An optical resonant reflection biosensor using a guided-mode resonance filter is one of the most promising label-free optical immunosensors due to a sharp reflectance peak and a high sensitivity to the changes of optical path length. We have simulated this type of biosensor using rigorous coupled wave theory to calculate the limit of detection of the thickness of the target protein layer. Theoretically, our biosensor has an estimated ability to detect thickness change approximately the size of typical antigen proteins. We have also investigated the effects of the absorption and divergence of the incident light on the detection ability of the biosensor.

  9. Improvement in Limit of Detection of Enzymatic Biogas Sensor Utilizing Chromatography Paper for Breath Analysis.

    Science.gov (United States)

    Motooka, Masanobu; Uno, Shigeyasu

    2018-02-02

    Breath analysis is considered to be an effective method for point-of-care diagnosis due to its noninvasiveness, quickness and simplicity. Gas sensors for breath analysis require detection of low-concentration substances. In this paper, we propose that reduction of the background current improves the limit of detection of enzymatic biogas sensors utilizing chromatography paper. After clarifying the cause of the background current, we reduced the background current by improving the fabrication process of the sensors utilizing paper. Finally, we evaluated the limit of detection of the sensor with the sample vapor of ethanol gas. The experiment showed about a 50% reduction of the limit of detection compared to previously-reported sensor. This result presents the possibility of the sensor being applied in diagnosis, such as for diabetes, by further lowering the limit of detection.

  10. Determining the lower limit of detection for personnel dosimetry systems

    International Nuclear Information System (INIS)

    Roberson, P.L.; Carlson, R.D.

    1992-01-01

    A simple method for determining the lower limit of detection (LLD) for personnel dosimetry systems is described. The method relies on the definition of a critical level and a detection level. The critical level is the signal level above which a result has a small probability of being due to a fluctuation of the background. All results below the critical level should not be reported as an indication of a positive result. The detection level is the net signal level (i.e., dose received) above which there is a high confidence that a true reading will be detected and reported as a qualitatively positive result. The detection level may be identified as the LLD. A simple formula is derived to allow the calculation of the LLD under various conditions. This type of formula is being used by the Department of Energy Laboratory Accreditation Program (DOELAP) for personnel dosimetry. Participants in either the National Voluntary Laboratory Accreditation Program (NVLAP) for personnel dosimetry or DOELAP can use performance test results along with a measurement of background levels to estimate the LLDs for their dosimetry system. As long as they maintain their dosimetry system such that the LLDs are less than half the lower limit of the NVLAP or DOELAP test exposure ranges, dosimetry laboratories can avoid testing failures due to poor performance at very low exposures

  11. How low can the detection limit go with VPD-TXRF

    International Nuclear Information System (INIS)

    Wang, J.; Balazs, M.; Pianetta, P.; Baur, K.; Brennan, S.; Boone, T.; Rosamilia, J.

    2000-01-01

    The detection limit for synchrotron radiation total reflection x-ray fluorescence (TXRF) that can routinely be achieved for transition metals is about 8E7 atoms/cm 2 for a standard 1000 second counting time. This high sensitivity can be further improved by using a pre-concentration process such as vapor phase decomposition (VPD). The sensitivity enhancement of VPD-TXRF over TXRF is usually estimated from the ratio of the total wafer surface area to the instrumental sampling area on the wafer. For example, a 200 mm wafer with a 5 mm edge exclusion has a total surface area of 283.5 cm 2 . Assuming a sampling area of 0.126 cm 2 for the TXRF instrument at the Stanford Synchrotron Radiation Laboratory (SSRL) the gain in sensitivity for the VPD-TXRF technique will be 1 : 2250. This means, theoretically, that the TXRF detection limit of 8E7 atoms/cm 2 could be further reduced to 3.6 E4 atoms/cm 2 by applying this technique. During the VPD process, the contaminants on the wafer surface will be collected into a single droplet and dried on the wafer surface for TXRF analysis. However, impurities in the UPW (ultra pure water), chemicals or from handling cannot be ignored. Our investigation of wafers subjected, to different cleaning processes has revealed that background signals on the dry spot could arise from the VPD process itself. Therefore, the baseline determined by the purity of the UPW and starting chemicals limits the detection limits of VPD-SR-TXRF. (author)

  12. Visualizing the Limits of Low Vision in Detecting Natural Image Features

    NARCIS (Netherlands)

    Hogervorst, M.A.; Damme, W.J.M. van

    2008-01-01

    Purpose. The purpose of our study was to develop a tool to visualize the limitations posed by visual impairments in detecting small and low-contrast elements in natural images. This visualization tool incorporates existing models of several aspects of visual perception, such as the band-limited

  13. Minimum detection limit and spatial resolution of thin-sample field-emission electron probe microanalysis

    International Nuclear Information System (INIS)

    Kubo, Yugo; Hamada, Kotaro; Urano, Akira

    2013-01-01

    The minimum detection limit and spatial resolution for a thinned semiconductor sample were determined by electron probe microanalysis (EPMA) using a Schottky field emission (FE) electron gun and wavelength dispersive X-ray spectrometry. Comparison of the FE-EPMA results with those obtained using energy dispersive X-ray spectrometry in conjunction with scanning transmission electron microscopy, confirmed that FE-EPMA is largely superior in terms of detection sensitivity. Thin-sample FE-EPMA is demonstrated as a very effective method for high resolution, high sensitivity analysis in a laboratory environment because a high probe current and high signal-to-noise ratio can be achieved. - Highlights: • Minimum detection limit and spatial resolution determined for FE-EPMA. • Detection sensitivity of FE-EPMA greatly superior to that of STEM-EDX. • Minimum detection limit and spatial resolution controllable by probe current

  14. Calculation of risk-based detection limits for radionuclides in the liquid effluents from Korean nuclear power plants

    International Nuclear Information System (INIS)

    Cheong, Jae Hak

    2017-01-01

    In order to review if present detection limits of radionuclides in liquid effluent from nuclear power plants are effective enough to warrant compliance with regulatory discharge limits, a risk-based approach is developed to derive a new detection limit for each radionuclide based on radiological criteria. Equations and adjustment factors are also proposed to discriminate the validity of the detection limits for multiple radionuclides in the liquid effluent with or without consideration of the nuclide composition. From case studies to three nuclear power plants in Korea with actual operation data from 2006 to 2015, the present detection limits have turned out to be effective for Hanul Unit 1 but may not be sensitive enough for Kori Unit 1 (8 out of 14 radionuclides) and Wolsong Unit 1 (9 out of 42 radionuclides). However, it is shown that the present detection limits for the latter two nuclear power plants can be justified, if credit is given to the radionuclide composition. Otherwise, consideration should be given to adjustment of the present detection limits. The risk-based approach of this study can be used to determine the validity of established detection limits of a specific nuclear power plant. (author)

  15. Gold nanoparticle-based low limit of detection Love wave biosensor for carcinoembryonic antigens.

    Science.gov (United States)

    Li, Shuangming; Wan, Ying; Su, Yan; Fan, Chunhai; Bhethanabotla, Venkat R

    2017-09-15

    In this work, a Love wave biosensing platform is described for detecting cancer-related biomarker carcinoembryonic antigen (CEA). An ST 90°-X quartz Love wave device with a layer of SiO 2 waveguide was combined with gold nanoparticles (Au NPs) to amplify the mass loading effect of the acoustic wave sensor to achieve a limit of detection of 37pg/mL. The strategy involves modifying the Au NPs with anti-CEA antibody conjugates to form nanoprobes in a sandwich immunoassay. The unamplified detection limit of the Love wave biosensor is 9.4ng/mL. This 2-3 order of magnitude reduction in the limit of detection brings the SAW platform into the range useful for clinical diagnosis. Measurement electronics and microfluidics are easily constructed for acoustic wave biosensors, such as the Love wave device described here, allowing for robust platforms for point of care applications for cancer biomarkers in general. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Detection limit of 238U by gamma spectrometry

    International Nuclear Information System (INIS)

    Tartaglione, A.; Blostein, J.; Mayer, R

    2004-01-01

    The detection limit of 238 U was determined by gamma spectra measurements of a depleted uranium sample using four NaI(Tl) scintillators in a compact arrangement.The sample was shielded with 5 and 10 cm of lead.Two different methods for data processing were used and compared.It was established that an appropriate array of 40 detectors could establish the presence of 220 g of this material in only 5 minutes [es

  17. Recommendations regarding higher axlemass limits for axles fitted with wide base tyres

    CSIR Research Space (South Africa)

    Roux, MP

    2011-01-01

    Full Text Available This paper presents the results of an investigation into possible higher axle mass limits for axles and axle units fitted with wide base tyres, i.e. tyres with nominal section widths of 385 mm, 425 mm and 445 mm, by comparing the road wear caused...

  18. Improved detection limit in rapid detection of human enterovirus 71 and coxsackievirus A16 by a novel reverse transcription-isothermal multiple-self-matching-initiated amplification assay.

    Science.gov (United States)

    Ding, Xiong; Nie, Kai; Shi, Lei; Zhang, Yong; Guan, Li; Zhang, Dan; Qi, Shunxiang; Ma, Xuejun

    2014-06-01

    Rapid detection of human enterovirus 71 (EV71) and coxsackievirus A16 (CVA16) is important in the early phase of hand-foot-and-mouth disease (HFMD). In this study, we developed and evaluated a novel reverse transcription-isothermal multiple-self-matching-initiated amplification (RT-IMSA) assay for the rapid detection of EV71 and CVA16 by use of reverse transcriptase, together with a strand displacement DNA polymerase. Real-time RT-IMSA assays using a turbidimeter and visual RT-IMSA assays to detect EV71 and CVA16 were established and completed in 1 h, and the reported corresponding real-time reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assays targeting the same regions of the VP1 gene were adopted as parallel tests. Through testing VP1 RNAs transcribed in vitro, the real-time RT-IMSA assays exhibited better linearity of quantification, with R(2) values of 0.952 (for EV71) and 0.967 (for CVA16), than the real-time RT-LAMP assays, which had R(2) values of 0.803 (for EV71) and 0.904 (for CVA16). Additionally, the detection limits of the real-time RT-IMSA assays (approximately 937 for EV71 and 67 for CVA16 copies/reaction) were higher than those of real-time RT-LAMP assays (approximately 3,266 for EV71 and 430 for CVA16 copies/reaction), and similar results were observed in the visual RT-IMSA assays. The new approaches also possess high specificities for the corresponding targets, with no cross-reactivity observed. In clinical assessment, compared to commercial reverse transcription-quantitative PCR (qRT-PCR) kits, the diagnostic sensitivities of the real-time RT-IMSA assays (96.4% for EV71 and 94.6% for CVA16) were higher than those of the real-time RT-LAMP assays (91.1% for EV71 and 90.8% for CVA16). The visual RT-IMSA assays also exhibited the same results. In conclusion, this proof-of-concept study suggests that the novel RT-IMSA assay is superior to the RT-LAMP assay in terms of detection limit and has the potential to rapidly detect EV71

  19. Determination and Interpretation of Characteristic Limits for Radioactivity Measurements: Decision Threshhold, Detection Limit and Limits of the Confidence Interval

    International Nuclear Information System (INIS)

    2017-01-01

    Since 2004, the environment programme of the IAEA has included activities aimed at developing a set of procedures for analytical measurements of radionuclides in food and the environment. Reliable, comparable and fit for purpose results are essential for any analytical measurement. Guidelines and national and international standards for laboratory practices to fulfil quality assurance requirements are extremely important when performing such measurements. The guidelines and standards should be comprehensive, clearly formulated and readily available to both the analyst and the customer. ISO 11929:2010 is the international standard on the determination of the characteristic limits (decision threshold, detection limit and limits of the confidence interval) for measuring ionizing radiation. For nuclear analytical laboratories involved in the measurement of radioactivity in food and the environment, robust determination of the characteristic limits of radioanalytical techniques is essential with regard to national and international regulations on permitted levels of radioactivity. However, characteristic limits defined in ISO 11929:2010 are complex, and the correct application of the standard in laboratories requires a full understanding of various concepts. This publication provides additional information to Member States in the understanding of the terminology, definitions and concepts in ISO 11929:2010, thus facilitating its implementation in Member State laboratories.

  20. Weighted Polynomial Approximation for Automated Detection of Inspiratory Flow Limitation

    Directory of Open Access Journals (Sweden)

    Sheng-Cheng Huang

    2017-01-01

    Full Text Available Inspiratory flow limitation (IFL is a critical symptom of sleep breathing disorders. A characteristic flattened flow-time curve indicates the presence of highest resistance flow limitation. This study involved investigating a real-time algorithm for detecting IFL during sleep. Three categories of inspiratory flow shape were collected from previous studies for use as a development set. Of these, 16 cases were labeled as non-IFL and 78 as IFL which were further categorized into minor level (20 cases and severe level (58 cases of obstruction. In this study, algorithms using polynomial functions were proposed for extracting the features of IFL. Methods using first- to third-order polynomial approximations were applied to calculate the fitting curve to obtain the mean absolute error. The proposed algorithm is described by the weighted third-order (w.3rd-order polynomial function. For validation, a total of 1,093 inspiratory breaths were acquired as a test set. The accuracy levels of the classifications produced by the presented feature detection methods were analyzed, and the performance levels were compared using a misclassification cobweb. According to the results, the algorithm using the w.3rd-order polynomial approximation achieved an accuracy of 94.14% for IFL classification. We concluded that this algorithm achieved effective automatic IFL detection during sleep.

  1. Aerosol quantification with the Aerodyne Aerosol Mass Spectrometer: detection limits and ionizer background effects

    Directory of Open Access Journals (Sweden)

    S. Borrmann

    2009-02-01

    Full Text Available Systematic laboratory experiments were performed to investigate quantification of various species with two versions of the Aerodyne Aerosol Mass Spectrometer, a Quadrupole Aerosol Mass Spectrometer (Q-AMS and a compact Time-of-Flight Aerosol Mass Spectrometer (c-ToF-AMS. Here we present a new method to continuously determine the detection limits of the AMS analyzers during regular measurements, yielding detection limit (DL information under various measurement conditions. Minimum detection limits range from 0.03 μg m−3 (nitrate, sulfate, and chloride up to 0.5 μg m−3 (organics for the Q-AMS. Those of the c-ToF-AMS are found between 0.003 μg m−3 (nitrate, sulfate and 0.03 μg m−3 (ammonium, organics. The DL values found for the c-ToF-AMS were ~10 times lower than those of the Q-AMS, mainly due to differences in ion duty cycle. Effects causing an increase of the detection limits include long-term instrument contamination, measurement of high aerosol mass concentrations and short-term instrument history. The self-cleaning processes which reduce the instrument background after measurement of large aerosol concentrations as well as the influences of increased instrument background on mass concentration measurements are discussed. Finally, improvement of detection limits by extension of averaging time intervals, selected or reduced ion monitoring, and variation of particle-to-background measurement ratio are investigated.

  2. Limit cycles via higher order perturbations for some piecewise differential systems

    Science.gov (United States)

    Buzzi, Claudio A.; Lima, Maurício Firmino Silva; Torregrosa, Joan

    2018-05-01

    A classical perturbation problem is the polynomial perturbation of the harmonic oscillator, (x‧ ,y‧) =(- y + εf(x , y , ε) , x + εg(x , y , ε)) . In this paper we study the limit cycles that bifurcate from the period annulus via piecewise polynomial perturbations in two zones separated by a straight line. We prove that, for polynomial perturbations of degree n , no more than Nn - 1 limit cycles appear up to a study of order N. We also show that this upper bound is reached for orders one and two. Moreover, we study this problem in some classes of piecewise Liénard differential systems providing better upper bounds for higher order perturbation in ε, showing also when they are reached. The Poincaré-Pontryagin-Melnikov theory is the main technique used to prove all the results.

  3. Including Below Detection Limit Samples in Post Decommissioning Soil Sample Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hwan; Yim, Man Sung [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    To meet the required standards the site owner has to show that the soil at the facility has been sufficiently cleaned up. To do this one must know the contamination of the soil at the site prior to clean up. This involves sampling that soil to identify the degree of contamination. However there is a technical difficulty in determining how much decontamination should be done. The problem arises when measured samples are below the detection limit. Regulatory guidelines for site reuse after decommissioning are commonly challenged because the majority of the activity in the soil at or below the limit of detection. Using additional statistical analyses of contaminated soil after decommissioning is expected to have the following advantages: a better and more reliable probabilistic exposure assessment, better economics (lower project costs) and improved communication with the public. This research will develop an approach that defines an acceptable method for demonstrating compliance of decommissioned NPP sites and validates that compliance. Soil samples from NPP often contain censored data. Conventional methods for dealing with censored data sets are statistically biased and limited in their usefulness.

  4. Detection limit for rate fluctuations in inhomogeneous Poisson processes

    Science.gov (United States)

    Shintani, Toshiaki; Shinomoto, Shigeru

    2012-04-01

    Estimations of an underlying rate from data points are inevitably disturbed by the irregular occurrence of events. Proper estimation methods are designed to avoid overfitting by discounting the irregular occurrence of data, and to determine a constant rate from irregular data derived from a constant probability distribution. However, it can occur that rapid or small fluctuations in the underlying density are undetectable when the data are sparse. For an estimation method, the maximum degree of undetectable rate fluctuations is uniquely determined as a phase transition, when considering an infinitely long series of events drawn from a fluctuating density. In this study, we analytically examine an optimized histogram and a Bayesian rate estimator with respect to their detectability of rate fluctuation, and determine whether their detectable-undetectable phase transition points are given by an identical formula defining a degree of fluctuation in an underlying rate. In addition, we numerically examine the variational Bayes hidden Markov model in its detectability of rate fluctuation, and determine whether the numerically obtained transition point is comparable to those of the other two methods. Such consistency among these three principled methods suggests the presence of a theoretical limit for detecting rate fluctuations.

  5. Detection limit for rate fluctuations in inhomogeneous Poisson processes.

    Science.gov (United States)

    Shintani, Toshiaki; Shinomoto, Shigeru

    2012-04-01

    Estimations of an underlying rate from data points are inevitably disturbed by the irregular occurrence of events. Proper estimation methods are designed to avoid overfitting by discounting the irregular occurrence of data, and to determine a constant rate from irregular data derived from a constant probability distribution. However, it can occur that rapid or small fluctuations in the underlying density are undetectable when the data are sparse. For an estimation method, the maximum degree of undetectable rate fluctuations is uniquely determined as a phase transition, when considering an infinitely long series of events drawn from a fluctuating density. In this study, we analytically examine an optimized histogram and a Bayesian rate estimator with respect to their detectability of rate fluctuation, and determine whether their detectable-undetectable phase transition points are given by an identical formula defining a degree of fluctuation in an underlying rate. In addition, we numerically examine the variational Bayes hidden Markov model in its detectability of rate fluctuation, and determine whether the numerically obtained transition point is comparable to those of the other two methods. Such consistency among these three principled methods suggests the presence of a theoretical limit for detecting rate fluctuations.

  6. Improved detection limits for phthalates by selective solid-phase micro-extraction

    KAUST Repository

    Zia, Asif I.; Afsarimanesh, Nasrin; Xie, Li; Nag, Anindya; Al-Bahadly, I. H.; Yu, P. L.; Kosel, Jü rgen

    2016-01-01

    Presented research reports on an improved method and enhanced limits of detection for phthalates; a hazardous additive used in the production of plastics by solid-phase micro-extraction (SPME) polymer in comparison to molecularly imprinted solid

  7. Fabrication of Stretchable Copper Coated Carbon Nanotube Conductor for Non-Enzymatic Glucose Detection Electrode with Low Detection Limit and Selectivity

    Directory of Open Access Journals (Sweden)

    Dawei Jiang

    2018-03-01

    Full Text Available The increasing demand for wearable glucose sensing has stimulated growing interest in stretchable electrodes. The development of the electrode materials having large stretchability, low detection limit, and good selectivity is the key component for constructing high performance wearable glucose sensors. In this work, we presented fabrication of stretchable conductor based on the copper coated carbon nanotube sheath-core fiber, and its application as non-enzymatic electrode for glucose detection with high stretchability, low detection limit, and selectivity. The sheath-core fiber was fabricated by coating copper coated carbon nanotube on a pre-stretched rubber fiber core followed by release of pre-stretch, which had a hierarchically buckled structure. It showed a small resistance change as low as 27% as strain increasing from 0% to 500% strain, and a low resistance of 0.4 Ω·cm−1 at strain of 500%. This electrode showed linear glucose concentration detection in the range between 0.05 mM and 5 mM and good selectivity against sucrose, lactic acid, uric acid, acrylic acid in phosphate buffer saline solution, and showed stable signal in high salt concentration. The limit of detection (LOD was 0.05 mM, for the range of 0.05–5 mM, the sensitivity is 46 mA·M−1. This electrode can withstand large strain of up to 60% with negligible influence on its performance.

  8. The detection limits of antimicrobial agents in cow's milk by a simple Yoghurt Culture Test.

    Science.gov (United States)

    Mohsenzadeh, M; Bahrainipour, A

    2008-09-15

    The aim of this study was to study performance of Yoghurt Culture Test (YCT) in the detection of antimicrobial residues in milk. For this purpose, the sensitivity of YCT for 15 antibiotics were determined. For each drug, 8 concentrations were tested. The detection limits of YCT at 2.5 h and 4 h incubation were determined (microg kg(-1)): 15 and 37.5, penicillin G; 4 and 5, ampicillin; 5 and 7.5, amoxycillin; 100 and 200, cephalexin; 80 and 100, cefazoline; 100 and 200, oxytetracycline; 500 and 100, chlortetracycline; 100 and 200, tetracycline; 150 and 200, doxycycline; 200 and 400, sulphadimidine; 500 and 1000, gentamycin; 1000 and 1500, spectinomycin; 400 and 500, erythromycin; 50 and 100, tylosin; 5000 and 10000, chloramphenicol. The YCT detection limits at 2.5 h incubation for ampicillin, cephalexin, tetracycline, oxytetracycline and tylosin are similar to those obtained as Maximum Residue Limit (MRL) according to Regulation 2377/90 EEC as set out by the European Union. In addition the detection limits of YCT for some antibiotics were lower than some of microbial inhibitor test.

  9. Limited interlaboratory comparison of Schmallenberg virus antibody detection in serum samples

    DEFF Research Database (Denmark)

    van der Poel, W. H. M.; Cay, B.; Zientara, S.

    2014-01-01

    Eight veterinary institutes in seven different countries in Europe participated in a limited interlaboratory comparison trial to evaluate laboratory performances of Schmallenberg virus (SBV) antibody detection in serum. Seven different sheep sera and three different cattle sera were circulated, a...

  10. Detection limits for nanoparticles in solution with classical turbidity spectra

    Science.gov (United States)

    Le Blevennec, G.

    2013-09-01

    Detection of nanoparticles in solution is required to manage safety and environmental problems. Spectral transmission turbidity method has now been known for a long time. It is derived from the Mie Theory and can be applied to any number of spheres, randomly distributed and separated by large distance compared to wavelength. Here, we describe a method for determination of size, distribution and concentration of nanoparticles in solution using UV-Vis transmission measurements. The method combines Mie and Beer Lambert computation integrated in a best fit approximation. In a first step, a validation of the approach is completed on silver nanoparticles solution. Verification of results is realized with Transmission Electronic Microscopy measurements for size distribution and an Inductively Coupled Plasma Mass Spectrometry for concentration. In view of the good agreement obtained, a second step of work focuses on how to manage the concentration to be the most accurate on the size distribution. Those efficient conditions are determined by simple computation. As we are dealing with nanoparticles, one of the key points is to know what the size limits reachable are with that kind of approach based on classical electromagnetism. In taking into account the transmission spectrometer accuracy limit we determine for several types of materials, metals, dielectrics, semiconductors the particle size limit detectable by such a turbidity method. These surprising results are situated at the quantum physics frontier.

  11. Improvement of detection limits of PIXE by substrate signal reduction

    International Nuclear Information System (INIS)

    Beaulieu, S.; Nejedly, Z.; Campbell, J.L.; Edwards, G.C.; Dias, G.M.

    2002-01-01

    Limits of detection (LODs) for aerosol samples collected using PIXE International cascade impactors, were improved approximately 50% after reducing the cross-sectional area of the analytical beam based on results obtained from microscope photographs of aerosol deposits. Improvements in LODs were most noticeable for selected elements collected on the smaller stages of the impactor (stages 1-3)

  12. Calculation of the detection limits for radionuclides identified in gamma-ray spectra based on post-processing peak analysis results.

    Science.gov (United States)

    Korun, M; Vodenik, B; Zorko, B

    2018-03-01

    A new method for calculating the detection limits of gamma-ray spectrometry measurements is presented. The method is applicable for gamma-ray emitters, irrespective of the influences of the peaked background, the origin of the background and the overlap with other peaks. It offers the opportunity for multi-gamma-ray emitters to calculate the common detection limit, corresponding to more peaks. The detection limit is calculated by approximating the dependence of the uncertainty in the indication on its value with a second-order polynomial. In this approach the relation between the input quantities and the detection limit are described by an explicit expression and can be easy investigated. The detection limit is calculated from the data usually provided by the reports of peak-analyzing programs: the peak areas and their uncertainties. As a result, the need to use individual channel contents for calculating the detection limit is bypassed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Signal detection without finite-energy limits to quantum resolution

    OpenAIRE

    Luis Aina, Alfredo

    2013-01-01

    We show that there are extremely simple signal detection schemes where the finiteness of energy resources places no limit on the resolution. On the contrary, larger resolution can be obtained with lower energy. To this end the generator of the signal-dependent transformation encoding the signal information on the probe state must be different from the energy. We show that the larger the deviation of the probe state from being the minimum-uncertainty state, the better the resolution.

  14. In vitro bioassays for detecting dioxin-like activity--application potentials and limits of detection, a review.

    Science.gov (United States)

    Eichbaum, Kathrin; Brinkmann, Markus; Buchinger, Sebastian; Reifferscheid, Georg; Hecker, Markus; Giesy, John P; Engwall, Magnus; van Bavel, Bert; Hollert, Henner

    2014-07-15

    Use of in vitro assays as screening tool to characterize contamination of a variety of environmental matrices has become an increasingly popular and powerful toolbox in the field of environmental toxicology. While bioassays cannot entirely substitute analytical methods such as gas chromatography-mass spectrometry (GC-MS), the increasing improvement of cell lines and standardization of bioassay procedures enhance their utility as bioanalytical pre-screening tests prior to more targeted chemical analytical investigations. Dioxin-receptor-based assays provide a holistic characterization of exposure to dioxin-like compounds (DLCs) by integrating their overall toxic potential, including potentials of unknown DLCs not detectable via e.g. GC-MS. Hence, they provide important additional information with respect to environmental risk assessment of DLCs. This review summarizes different in vitro bioassay applications for detection of DLCs and considers the comparability of bioassay and chemical analytically derived toxicity equivalents (TEQs) of different approaches and various matrices. These range from complex samples such as sediments through single reference to compound mixtures. A summary of bioassay derived detection limits (LODs) showed a number of current bioassays to be equally sensitive as chemical methodologies, but moreover revealed that most of the bioanalytical studies conducted to date did not report their LODs, which represents a limitation with regard to low potency samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Predictive inference for best linear combination of biomarkers subject to limits of detection.

    Science.gov (United States)

    Coolen-Maturi, Tahani

    2017-08-15

    Measuring the accuracy of diagnostic tests is crucial in many application areas including medicine, machine learning and credit scoring. The receiver operating characteristic (ROC) curve is a useful tool to assess the ability of a diagnostic test to discriminate between two classes or groups. In practice, multiple diagnostic tests or biomarkers are combined to improve diagnostic accuracy. Often, biomarker measurements are undetectable either below or above the so-called limits of detection (LoD). In this paper, nonparametric predictive inference (NPI) for best linear combination of two or more biomarkers subject to limits of detection is presented. NPI is a frequentist statistical method that is explicitly aimed at using few modelling assumptions, enabled through the use of lower and upper probabilities to quantify uncertainty. The NPI lower and upper bounds for the ROC curve subject to limits of detection are derived, where the objective function to maximize is the area under the ROC curve. In addition, the paper discusses the effect of restriction on the linear combination's coefficients on the analysis. Examples are provided to illustrate the proposed method. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Decreasing of the detection limit for gamma-ray Spectrometry with the influence of sample treatment

    International Nuclear Information System (INIS)

    Karami, M.; Sadighzadeh, A.; Asgharizadeh, F.; Sardari, D.; Tavassoli, A.; Arbabi, A.; Hochaghani, O.

    2009-01-01

    Full text: In this study the ash method has been applied for environmental sample treatment in order to decrease of the detection limit in gamma-ray spectrometry for low level radioactivity measurements. Detection limit in gamma ray spectrometry is the smallest expectation value of the net counting rate that can be detected on given probabilities. The environmental test samples have been changed into ash using a suitable oven. The heating were made under controlled temperature to avoid the escape of some radionuclides such as radiocaesium. The ash samples were measured by high resolution gamma-ray spectrometry system. (author)

  17. 40 CFR Appendix B to Part 136 - Definition and Procedure for the Determination of the Method Detection Limit-Revision 1.11

    Science.gov (United States)

    2010-07-01

    ... calculated method detection limit. To insure that the estimate of the method detection limit is a good...) where: MDL = the method detection limit t(n-1,1- α=.99) = the students' t value appropriate for a 99... Determination of the Method Detection Limit-Revision 1.11 B Appendix B to Part 136 Protection of Environment...

  18. Limits of detection of americium-241 in air

    International Nuclear Information System (INIS)

    Bereznai, T.

    1995-01-01

    Seven semiconductor detectors with various characteristics (type, form, size, etc.) were tested and compared in gamma-spectrometric assays for Am-241 aerosols in air. The problem at hand (determining a low activity or attaining a set detection limit (approx. 2 mBq/m 3 ) as soon as possible after sampling) was solved best by a large-volume n-type detector with a Be-window. In addition to the detector parameters commonly used (energy resolution and effectiveness), the peak-to-background ratio and the background counting rate at the gamma-energy of the nuclide to be determined are important criteria influencing the choice of equipment. (orig.) [de

  19. Detection and grading of dAVF: prospects and limitations of 3T MRI.

    Science.gov (United States)

    Bink, Andrea; Berkefeld, Joachim; Wagner, Marlies; You, Se-Jong; Ackermann, Hanns; Lorenz, Matthias W; Senft, Christian; du Mesnil de Rochemont, Richard

    2012-02-01

    DSA is currently the criterion standard for the assessment of dural arteriovenous fistulas (dAVF). Recently, evolving MRA techniques have emerged as a non-invasive alternative. The aim of this study is to assess the value of 3 T MRI in detecting and describing dAVF and to determine whether MRI can replace DSA as diagnostic procedure. A total of 19 patients with dAVF and 19 without dAVF underwent the same MRI protocol, including 3D time-of-flight MRA and time-resolved contrast-enhanced MRA. The images were evaluated retrospectively by three independent readers with different levels of experience blinded to clinical information. The readers assessed the presence, the site, the venous drainage and the feeders of dAVF. Sensitivity, specificity, accuracy, intertechnique and interobserver agreements were calculated. DAVF can be detected with high sensitivity, specificity and accuracy by experienced and also by less experienced readers. However, MRI has limitations when used for grading and evaluation of the angioarchitecture of the dAVF. Different experience, the limited resolution of MRI and its inability to selectively display arteries were the reasons for these limitations. With MRI dAVF can be detected reliably. Nevertheless, at present MRI can not fully replace DSA, especially for treatment planning.

  20. Bayesian-statistical decision threshold, detection limit, and confidence interval in nuclear radiation measurement

    International Nuclear Information System (INIS)

    Weise, K.

    1998-01-01

    When a contribution of a particular nuclear radiation is to be detected, for instance, a spectral line of interest for some purpose of radiation protection, and quantities and their uncertainties must be taken into account which, such as influence quantities, cannot be determined by repeated measurements or by counting nuclear radiation events, then conventional statistics of event frequencies is not sufficient for defining the decision threshold, the detection limit, and the limits of a confidence interval. These characteristic limits are therefore redefined on the basis of Bayesian statistics for a wider applicability and in such a way that the usual practice remains as far as possible unaffected. The principle of maximum entropy is applied to establish probability distributions from available information. Quantiles of these distributions are used for defining the characteristic limits. But such a distribution must not be interpreted as a distribution of event frequencies such as the Poisson distribution. It rather expresses the actual state of incomplete knowledge of a physical quantity. The different definitions and interpretations and their quantitative consequences are presented and discussed with two examples. The new approach provides a theoretical basis for the DIN 25482-10 standard presently in preparation for general applications of the characteristic limits. (orig.) [de

  1. Detection limits of intraoperative near infrared imaging for tumor resection.

    Science.gov (United States)

    Thurber, Greg M; Figueiredo, Jose-Luiz; Weissleder, Ralph

    2010-12-01

    The application of fluorescent molecular imaging to surgical oncology is a developing field with the potential to reduce morbidity and mortality. However, the detection thresholds and other requirements for successful intervention remain poorly understood. Here we modeled and experimentally validated depth and size of detection of tumor deposits, trade-offs in coverage and resolution of areas of interest, and required pharmacokinetics of probes based on differing levels of tumor target presentation. Three orthotopic tumor models were imaged by widefield epifluorescence and confocal microscopes, and the experimental results were compared with pharmacokinetic models and light scattering simulations to determine detection thresholds. Widefield epifluorescence imaging can provide sufficient contrast to visualize tumor margins and detect tumor deposits 3-5  mm deep based on labeled monoclonal antibodies at low objective magnification. At higher magnification, surface tumor deposits at cellular resolution are detectable at TBR ratios achieved with highly expressed antigens. A widefield illumination system with the capability for macroscopic surveying and microscopic imaging provides the greatest utility for varying surgical goals. These results have implications for system and agent designs, which ultimately should aid complete resection in most surgical beds and provide real-time feedback to obtain clean margins. © 2010 Wiley-Liss, Inc.

  2. Limits of detection in instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Guinn, V.P.

    1990-01-01

    Lower limits of detection (LLODs), frequently referred to simply as limits of detection and abbreviated as LODs, often appear in the literature of analytical chemistry - for numerous different methods of elemental and/or molecular analysis. In this chapter, one particular method of quantitative elemental analysis, that of instrumental neutron activation analysis (INAA), is the subject discussed, with reference to LODs. Particularly in the literature of neutron activation analysis (NAA), many tables of 'interference-free' NAA LODs are available. Not all of these are of much use, because (1) for many the definition used for LOD is not clear, or reasonable, (2) for many, the analysis conditions used are not clearly specified, and (3) for many, the analysis conditions used are specified, but not very practicable for most laboratories. For NAA work, such tables of interference-free LODs are, in any case, only applicable to samples in which, at the time of counting, only one radionuclide is present to any significant extent in the activated sample. It is important to note that tables of INAA LODs, per se, do not exist - since the LOD for a given element, under stated analysis conditions, can vary by orders of magnitude, depending on the elemental composition of the matrix in which it is present. For any given element, its INAA LOD will always be as large as, and usually much larger than, its tabulated 'interference-free' NAA LOD - how much larger depending upon the elemental composition of the matrix in which it is present. As discussed in this chapter, however, an INAA computer program exists that can calculate realistic INAA LODs for any elements of interest, in any kind of specified sample matrix, under any given set of analysis conditions

  3. Determination of hydrogen peroxide in water by chemiluminescence detection, (1). Flow injection type hydrogen peroxide detection system

    International Nuclear Information System (INIS)

    Yamashiro, Naoya; Uchida, Shunsuke; Satoh, Yoshiyuki; Morishima, Yusuke; Yokoyama, Hiroaki; Satoh, Tomonori; Sugama, Junichi; Yamada, Rie

    2004-01-01

    A flow injection type hydrogen peroxide detection system with a sub-ppb detection limit has been developed to determine hydrogen peroxide concentration in water sampled from a high temperature, high pressure hydrogen peroxide water loop. The hydrogen peroxide detector is based on luminol chemiluminescence spectroscopy. A small amount of sample water (20 μl) is mixed with a reagent mixture, an aqueous solution of luminol and Co 2+ catalyst, in a mixing cell which is installed just upstream from the detection cell. The optimum values for pH and the concentrations of luminol and Co 2+ ion have been determined to ensure a lower detectable limit and a higher reproducibility. The photocurrent detected by the detection system is expressed by a linear function of the hydrogen peroxide concentration in the region of lower concentration ([H 2 O 2 ] 2 O 2 ] in the region of higher concentration ([H 2 O 2 ] > 10 ppb). The luminous intensity of luminol chemiluminescence is the highest when pH of the reagent mixture is 11.0. Optimization of the major parameters gives the lowest detectable limit of 0.3 ppb. (author)

  4. The advantage of higher-order theory of mind in the game of limited bidding

    NARCIS (Netherlands)

    De Weerd, H.; Verheij, B.; van Eijck, J.; Verbrugge, L. C.

    2011-01-01

    Higher-order theory of mind is the ability to recursively model mental states of other agents. It is known that adults in general can reason adequately at the second order (covering attributions like "Alice knows that Bob knows that she wrote a novel under pseudonym"), but there are cognitive limits

  5. The detection of higher-order acoustic transitions is reflected in the N1 ERP.

    Science.gov (United States)

    Weise, Annekathrin; Schröger, Erich; Horváth, János

    2018-01-30

    The auditory system features various types of dedicated change detectors enabling the rapid parsing of auditory stimulation into distinct events. The activity of such detectors is reflected by the N1 ERP. Interestingly, certain acoustic transitions show an asymmetric N1 elicitation pattern: whereas first-order transitions (e.g., a change from a segment of constant frequency to a frequency glide [c-to-g change]) elicit N1, higher-order transitions (e.g., glide-to-constant [g-to-c] changes) do not. Consensus attributes this asymmetry to the absence of any available sensory mechanism that is able to rapidly detect higher-order changes. In contrast, our study provides compelling evidence for such a mechanism. We collected electrophysiological and behavioral data in a transient-detection paradigm. In each condition, a random (50%-50%) sequence of two types of tones occurred, which did or did not contain a transition (e.g., c-to-g and constant stimuli or g-to-c and glide tones). Additionally, the rate of pitch change of the glide varied (i.e., 10 vs. 40 semitones per second) in order to increase the number of responding neural assemblies. The rate manipulation modulated transient ERPs and behavioral detection performance for g-to-c transitions much stronger than for c-to-g transitions. The topographic and tomographic analyses suggest that the N1 response to c-to-g and also to g-to-c transitions emerged from the superior temporal gyrus. This strongly supports a sensory mechanism that allows the fast detection of higher-order changes. © 2018 Society for Psychophysiological Research.

  6. Investigation of a gamma sensitive Ge-detector with Marinelligeometry. Determination of the detection limits

    International Nuclear Information System (INIS)

    Moricz, P.

    1984-01-01

    Different Marinelli geometries have been compared with a 180 ml standard plastic breaker geometry as a reference. The results show that the Marinelli geometries are the best. E.g. the detection limit with a Marinelli geometry of 0.5 l is only half compared with the limit when the standard geometry is used. (Edv)

  7. Characteristics of right-sided colonic neoplasia and colonoscopy barriers limiting their early detection and prognosis: a review of the literature.

    Science.gov (United States)

    Fischbach, Wolfgang; Elsome, Rory; Amlani, Bharat

    2018-06-05

    Colonoscopy provides less protection from colorectal cancer in the right colon than the left. Areas covered: This review examines patient outcomes and colonoscopy success rates to identify factors that limit the protective effect of colonoscopy in the right colon. The MEDLINE and Embase databases were searched for literature from 2000 onwards, on the long-term outcomes and differences in screening practice between the right and left colon. In total, 12 systematic reviews (including nine meta-analyses) and 44 primary data records were included. Differences in patient outcomes and colonoscopy practice were identified between the right and left colon, suggesting that several factors, many of which disproportionally affect the right colon, impact lesion detection rates. Shorter withdrawal times reduce detection rates, while longer times significantly increase detection; mostly of adenomas in the right colon. Colonoscope attachments often only show a significant improvement in detection rates in the right colon, suggesting detection is more challenging due to visibility of the right colonic mucosa. Higher bowel cleansing grades significantly improve detection rates in the right colon compared to the left. Expert commentary: These findings confirm the need for continued improvement of colonoscopy effectiveness, and obligatory quality assessment, overall and especially in the right colon.

  8. Towards improving the detection limit of electron paramagnetic resonance (EPR) dosimetry of drywall (wallboard)

    Energy Technology Data Exchange (ETDEWEB)

    Mistry, R.; Thompson, J.W. [Dept. of Medical Physics and Applied Radiation Sciences, McMaster Univ., Hamilton, Ontario (Canada); Rink, W.J. [School of Geography and Earth Sciences, McMaster Univ., Hamilton, Ontario (Canada); Boreham, D. [Dept. of Medical Physics and Applied Radiation Sciences, McMaster Univ., Hamilton, Ontario (Canada)

    2009-07-01

    The intensity of the electron paramagnetic resonance (EPR) line corresponding to the carbonate free radical (CO{sub 3}{sup -}) in gypsum (CaSO{sub 4}{center_dot}2H{sub 2}O) drywall was previously shown to be proportional to absorbed dose. Heating irradiated drywall reduces the radiosensitive signal of the CO{sub 3}{sup -} radical. The response of the CO{sub 3}{sup -} EPR line to heat treatments is being studied in order to determine a background for an arbitrary drywall sample. Ultimately this is expected to improve the precision of dose measurements with drywall and to reduce the detection limit. Controlled heating of irradiated drywall was performed at temperatures between 50{sup o}C and 100{sup o}C. Although higher temperatures reduce the radiosensitive signal rapidly, the non-radiosensitive EPR signals are affected dramatically as well, presumably due to a phrase change from gypsum to plaster of Paris to anhydrite. (author)

  9. CpG Oligonucleotide and Interleukin 2 stimulation enables higher cytogenetic abnormality detection rates than 12-o-tetradecanolyphorbol-13-acetate in Asian patients with B-cell chronic lymphocytic leukemia (B-CLL).

    Science.gov (United States)

    Liaw, Fiona Pui San; Lau, Lai Ching; Lim, Alvin Soon Tiong; Lim, Tse Hui; Lee, Geok Yee; Tien, Sim Leng

    2014-12-01

    The present study was designed to compare abnormality detection rates using DSP30 + IL2 and 12-O-Tetradecanoylphorbol-13-acetate (TPA) in Asian patients with B-CLL. Hematological specimens from 47 patients (29 newly diagnosed, 18 relapsed) were established as 72 h-DSP30 + IL2 and TPA cultures. Standard methods were employed to identify clonal aberrations by conventional cytogenetics (CC). The B-CLL fluorescence in situ hybridization (FISH) panel comprised ATM, CEP12, D13S25, and TP53 probes. DSP30 + IL2 cultures had a higher chromosomal abnormality detection rate (67 %) compared to TPA (44 %, p 0.05). Thirteen cases with abnormalities were found exclusively in DSP30 + IL2 cultures compared to one found solely in TPA cultures. DSP30 + IL2 cultures were comparable to the FISH panel in detecting 11q-, +12 and 17p- but not 13q-. It also has a predilection for 11q- bearing leukemic cells compared to TPA. FISH had a higher abnormality detection rate (84.1 %) compared to CC (66.0 %) with borderline significance (p = 0.051), albeit limited by its coverage. In conclusion, DSP30 + IL2 showed a higher abnormality detection rate. However, FISH is indispensable to circumvent low mitotic indices and detect subtle abnormalities.

  10. Using a higher criticism statistic to detect modest effects in a genome-wide study of rheumatoid arthritis

    Science.gov (United States)

    2009-01-01

    In high-dimensional studies such as genome-wide association studies, the correction for multiple testing in order to control total type I error results in decreased power to detect modest effects. We present a new analytical approach based on the higher criticism statistic that allows identification of the presence of modest effects. We apply our method to the genome-wide study of rheumatoid arthritis provided in the Genetic Analysis Workshop 16 Problem 1 data set. There is evidence for unknown bias in this study that could be explained by the presence of undetected modest effects. We compared the asymptotic and empirical thresholds for the higher criticism statistic. Using the asymptotic threshold we detected the presence of modest effects genome-wide. We also detected modest effects using 90th percentile of the empirical null distribution as a threshold; however, there is no such evidence when the 95th and 99th percentiles were used. While the higher criticism method suggests that there is some evidence for modest effects, interpreting individual single-nucleotide polymorphisms with significant higher criticism statistics is of undermined value. The goal of higher criticism is to alert the researcher that genetic effects remain to be discovered and to promote the use of more targeted and powerful studies to detect the remaining effects. PMID:20018032

  11. Trace element analysis by EPMA in geosciences: detection limit, precision and accuracy

    Science.gov (United States)

    Batanova, V. G.; Sobolev, A. V.; Magnin, V.

    2018-01-01

    Use of the electron probe microanalyser (EPMA) for trace element analysis has increased over the last decade, mainly because of improved stability of spectrometers and the electron column when operated at high probe current; development of new large-area crystal monochromators and ultra-high count rate spectrometers; full integration of energy-dispersive / wavelength-dispersive X-ray spectrometry (EDS/WDS) signals; and the development of powerful software packages. For phases that are stable under a dense electron beam, the detection limit and precision can be decreased to the ppm level by using high acceleration voltage and beam current combined with long counting time. Data on 10 elements (Na, Al, P, Ca, Ti, Cr, Mn, Co, Ni, Zn) in olivine obtained on a JEOL JXA-8230 microprobe with tungsten filament show that the detection limit decreases proportionally to the square root of counting time and probe current. For all elements equal or heavier than phosphorus (Z = 15), the detection limit decreases with increasing accelerating voltage. The analytical precision for minor and trace elements analysed in olivine at 25 kV accelerating voltage and 900 nA beam current is 4 - 18 ppm (2 standard deviations of repeated measurements of the olivine reference sample) and is similar to the detection limit of corresponding elements. To analyse trace elements accurately requires careful estimation of background, and consideration of sample damage under the beam and secondary fluorescence from phase boundaries. The development and use of matrix reference samples with well-characterised trace elements of interest is important for monitoring and improving of the accuracy. An evaluation of the accuracy of trace element analyses in olivine has been made by comparing EPMA data for new reference samples with data obtained by different in-situ and bulk analytical methods in six different laboratories worldwide. For all elements, the measured concentrations in the olivine reference sample

  12. Application of Statistical Methods to Activation Analytical Results near the Limit of Detection

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Wanscher, B.

    1978-01-01

    Reporting actual numbers instead of upper limits for analytical results at or below the detection limit may produce reliable data when these numbers are subjected to appropriate statistical processing. Particularly in radiometric methods, such as activation analysis, where individual standard...... deviations of analytical results may be estimated, improved discrimination may be based on the Analysis of Precision. Actual experimental results from a study of the concentrations of arsenic in human skin demonstrate the power of this principle....

  13. TXRF 'measurements' of concentration distribution below the detection limit

    International Nuclear Information System (INIS)

    Kubala-Kukus, A.; Banas, D.; Braziewicz, J.; Majewska, U.; Mrowczynski, S.; Pajek, M.

    2000-01-01

    We demonstrate that a shape of the concentration distribution of the element in a set of samples, as measured by the TXRF method, can be determined even for the concentrations below the detection limit (DL). This can be done, when the measurements reporting the concentration below DL level are included properly in the analysis of the results. The method developed for such correction is presented and discussed. It is demonstrated that this correction is particularly important when the studied concentrations are close to the DL level of the method, which is a common case for TXRF. In the paper a precision of the developed correction is discussed in details, by using the results of numerical simulations of experiments for different concentration distributions and number of performed measurements. It is demonstrated that the factor, which limits the accuracy of the correction, is the number of measurements, not the correction procedure itself. The applicability and importance of the developed correction is demonstrated for routine TXRF analysis of different types of samples of bio-medical interest. (author)

  14. Investigation on feasibility and detection limits for determination of coating film thickness by neutron activation analysis

    International Nuclear Information System (INIS)

    Yao Maoying; Xu Jiayun; Zhang Dida; Yang Zunyong; Yao Zhenqiang; Wang Mingqiu; Gao Dangzhong

    2010-01-01

    A method for the determination of coating film thickness by neutron activation was proposed in this paper. After Au, Al and Cu et al.films were activated with a Am-Be neutron source, the characteristic γ-rays emitted by the activated nuclides in the films were counted with a HPGe γ spectrometer. The detection limits of film thickness by using a nuclear reactor neutron source were deduced on the basis of the γ-ray counts and the Monte-Carlo simulated detection efficiencies. The possible detection limits are typically 4-5 orders of magnitude better than those by fluorescent X-ray method, which is currently widely used to determine coating film thickness. (authors)

  15. Discuss the technology for decrease the detection limit of NaI(Tl) gamma spectrometer

    International Nuclear Information System (INIS)

    Guo Xiaobin; Qu Guopu; Liu Zhiying; Wang Hongyan; Wang Lieming

    2011-01-01

    The radioelement species is complex and quantity is few after nuclear explosion, thus it is hard to tell the difference when using the Nal (TI) Gamma spectrometer detection due to several kinds of the peak of nuclide overlapped in the scattering region. So there is a high demand for spectrometer stability, energy resolution, solution spectrum and minimum detective activity. The paper analysed the influenced factors to Nal (TI) Gamma spectrometer and the measures of detection limit decrease by experiments and MCNP simulation, which proposed the methods to reduce background through shielding in order to improve minimum detective activity. The experiment shows that choosing reasonable shielding can reduce the background effectively and improve the spectrometer low level radioactive detect ability. (authors)

  16. Variation in the limit-of-detection of the ProSpecT Campylobacter microplate enzyme immunoassay in stools spiked with emerging Campylobacter species.

    Science.gov (United States)

    Bojanić, Krunoslav; Midwinter, Anne Camilla; Marshall, Jonathan Craig; Rogers, Lynn Elizabeth; Biggs, Patrick Jon; Acke, Els

    2016-08-01

    Campylobacter enteritis in humans is primarily associated with C. jejuni/coli infection. The impact of other Campylobacter spp. is likely to be underestimated due to the bias of culture methods towards Campylobacter jejuni/coli diagnosis. Stool antigen tests are becoming increasingly popular and appear generally less species-specific. A review of independent studies of the ProSpecT® Campylobacter Microplate enzyme immunoassay (EIA) developed for C. jejuni/coli showed comparable diagnostic results to culture methods but the examination of non-jejuni/coli Campylobacter spp. was limited and the limit-of-detection (LOD), where reported, varied between studies. This study investigated LOD of EIA for Campylobacter upsaliensis, Campylobacter hyointestinalis and Campylobacter helveticus spiked in human stools. Multiple stools and Campylobacter isolates were used in three different concentrations (10(4)-10(9)CFU/ml) to reflect sample heterogeneity. All Campylobacter species evaluated were detectable by EIA. Multivariate analysis showed LOD varied between Campylobacter spp. and faecal consistency as fixed effects and individual faecal samples as random effects. EIA showed excellent performance in replicate testing for both within and between batches of reagents, in agreement between visual and spectrophotometric reading of results, and returned no discordance between the bacterial concentrations within independent dilution test runs (positive results with lower but not higher concentrations). This study shows how limitations in experimental procedures lead to an overestimation of consistency and uniformity of LOD for EIA that may not hold under routine use in diagnostic laboratories. Benefits and limitations for clinical practice and the influence on estimates of performance characteristics from detection of multiple Campylobacter spp. by EIA are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Evaluation of a single-item screening question to detect limited health literacy in peritoneal dialysis patients.

    Science.gov (United States)

    Jain, Deepika; Sheth, Heena; Bender, Filitsa H; Weisbord, Steven D; Green, Jamie A

    2014-01-01

    Studies have shown that a single-item question might be useful in identifying patients with limited health literacy. However, the utility of the approach has not been studied in patients receiving maintenance peritoneal dialysis (PD). We assessed health literacy in a cohort of 31 PD patients by administering the Rapid Estimate of Adult Literacy in Medicine (REALM) and a single-item health literacy (SHL) screening question "How confident are you filling out medical forms by yourself?" (Extremely, Quite a bit, Somewhat, A little bit, or Not at all). To determine the accuracy of the single-item question for detecting limited health literacy, we performed sensitivity and specificity analyses of the SHL and plotted the area under the receiver operating characteristic (AUROC) curve using the REALM as a reference standard. Using a cut-off of "Somewhat" or less confident, the sensitivity of the SHL for detecting limited health literacy was 80%, and the specificity was 88%. The positive likelihood ratio was 6.9. The SHL had an AUROC of 0.79 (95% confidence interval: 0.52 to 1.00). Our results show that the SHL could be effective in detecting limited health literacy in PD patients.

  18. RCRA materials analysis by laser-induced breakdown spectroscopy: Detection limits in soils

    International Nuclear Information System (INIS)

    Koskelo, A.; Cremers, D.A.

    1994-01-01

    The goal of the Technical Task Plan (TTP) that this report supports is research, development, testing and evaluation of a portable analyzer for RCRA and other metals. The instrumentation to be built will be used for field-screening of soils. Data quality is expected to be suitable for this purpose. The data presented in this report were acquired to demonstrate the detection limits for laser-induced breakdown spectroscopy (LIBS) of soils using instrument parameters suitable for fieldable instrumentation. The data are not expected to be the best achievable with the high pulse energies available in laboratory lasers. The report presents work to date on the detection limits for several elements in soils using LIBS. The elements targeted in the Technical Task Plan are antimony, arsenic, beryllium, cadmium, chromium, lead, selenium, and zirconium. Data for these elements are presented in this report. Also included are other data of interest to potential customers for the portable LIBS apparatus. These data are for barium, mercury, cesium and strontium. Data for uranium and thorium will be acquired during the tasks geared toward mixed waste characterization

  19. Power-limited low-thrust trajectory optimization with operation point detection

    Science.gov (United States)

    Chi, Zhemin; Li, Haiyang; Jiang, Fanghua; Li, Junfeng

    2018-06-01

    The power-limited solar electric propulsion system is considered more practical in mission design. An accurate mathematical model of the propulsion system, based on experimental data of the power generation system, is used in this paper. An indirect method is used to deal with the time-optimal and fuel-optimal control problems, in which the solar electric propulsion system is described using a finite number of operation points, which are characterized by different pairs of thruster input power. In order to guarantee the integral accuracy for the discrete power-limited problem, a power operation detection technique is embedded in the fourth-order Runge-Kutta algorithm with fixed step. Moreover, the logarithmic homotopy method and normalization technique are employed to overcome the difficulties caused by using indirect methods. Three numerical simulations with actual propulsion systems are given to substantiate the feasibility and efficiency of the proposed method.

  20. STATISTICAL METHODS FOR ENVIRONMENTAL APPLICATIONS USING DATA SETS WITH BELOW DETECTION LIMIT OBSERVATIONS AS INCORPORTED IN PROUCL 4.0

    Science.gov (United States)

    Nondetect (ND) or below detection limit (BDL) results cannot be measured accurately, and, therefore, are reported as less than certain detection limit (DL) values. However, since the presence of some contaminants (e.g., dioxin) in environmental media may pose a threat to human he...

  1. CARIES DETECTION WITH LASER FLUORESCENCE DEVICES. LIMITATIONS OF THEIR USE

    Directory of Open Access Journals (Sweden)

    Andreas Spaveras

    2017-03-01

    Data synthesis: DD and DDPen are useful devices for caries detection on the occlusal tooth surfaces. Their main advantages are the very high reproducibility of measurements (>0.90, the ease of handling and the quantification and monitoring capacity. Their main limitations are the relatively low specificity for enamel lesions, the necessity of unstained surfaces and absence of plaque and pastes during measurements and the absence of a universal, clinically functional calibration value (COV. Conclusion: Further studies are required for more reliable data analysis and clinical interpretation of the relevant results.

  2. Proposal for a methodology for the determination of the Detection Limit: Case of bulks detector for the Chlorothalonil

    International Nuclear Information System (INIS)

    Gonzalez G, J.; Parra M, C.M.; Romero R, R.M.

    1998-01-01

    As it usually found in the literature, the Lower Detection Limit for an analytical method is obtained by means of a simple statistical exercise whose value is seldom attained in practice. For this reason a method was designed for achieving a Practical Lower Detection Limit for the lowest concentration of the compound that could be detected, S= 2 R, with a probability of at least, 0.90. A methodological design was formulated to get a Practical Lower Detection Limit that is not timed consuming for the analyst. It is presented using an example and, additionally its benefits are discussed versus the unattainable values that are obtained by the traditional use of the standard deviation of a series of measurements of the compound at concentrations near zero, which is then multiplied by the t student for a one tailed test for n-1 degrees of freedom

  3. Higher-order harmonics of limited diffraction Bessel beams

    Science.gov (United States)

    Ding; Lu

    2000-03-01

    We investigate theoretically the nonlinear propagation of the limited diffraction Bessel beam in nonlinear media, under the successive approximation of the KZK equation. The result shows that the nth-order harmonic of the Bessel beam, like its fundamental component, is radially limited diffracting, and that the main beamwidth of the nth-order harmonic is exactly 1/n times that of the fundamental.

  4. Detection limits should be a thing of the past in gamma-ray spectrometry in general as well as in neutron activation analysis

    NARCIS (Netherlands)

    Blaauw, Menno

    2016-01-01

    In gamma-ray spectrometry with high-resolution detectors, full-energy peaks are often to be detected by a peak-search algorithm, with a threshold for detection. Detection limits can be derived from this. Detection limits are often computed along with measured activities or concentrations. When an

  5. Optimising Mycobacterium tuberculosis detection in resource limited settings.

    Science.gov (United States)

    Alfred, Nwofor; Lovette, Lawson; Aliyu, Gambo; Olusegun, Obasanya; Meshak, Panwal; Jilang, Tunkat; Iwakun, Mosunmola; Nnamdi, Emenyonu; Olubunmi, Onuoha; Dakum, Patrick; Abimiku, Alash'le

    2014-03-03

    The light-emitting diode (LED) fluorescence microscopy has made acid-fast bacilli (AFB) detection faster and efficient although its optimal performance in resource-limited settings is still being studied. We assessed the optimal performances of light and fluorescence microscopy in routine conditions of a resource-limited setting and evaluated the digestion time for sputum samples for maximum yield of positive cultures. Cross-sectional study. Facility-based involving samples of routine patients receiving tuberculosis treatment and care from the main tuberculosis case referral centre in northern Nigeria. The study included 450 sputum samples from 150 new patients with clinical diagnosis of pulmonary tuberculosis. The 450 samples were pooled into 150 specimens, examined independently with mercury vapour lamp (FM), LED CysCope (CY) and Primo Star iLED (PiLED) fluorescence microscopies, and with the Ziehl-Neelsen (ZN) microscopy to assess the performance of each technique compared with liquid culture. The cultured specimens were decontaminated with BD Mycoprep (4% NaOH-1% NLAC and 2.9% sodium citrate) for 10, 15 and 20 min before incubation in Mycobacterium growth incubator tube (MGIT) system and growth examined for acid-fast bacilli (AFB). Of the 150 specimens examined by direct microscopy: 44 (29%), 60 (40%), 49 (33%) and 64 (43%) were AFB positive by ZN, FM, CY and iLED microscopy, respectively. Digestion of sputum samples for 10, 15 and 20 min yielded mycobacterial growth in 72 (48%), 81 (54%) and 68 (45%) of the digested samples, respectively, after incubation in the MGIT system. In routine laboratory conditions of a resource-limited setting, our study has demonstrated the superiority of fluorescence microscopy over the conventional ZN technique. Digestion of sputum samples for 15 min yielded more positive cultures.

  6. Estimation of the limit of detection with a bootstrap-derived standard error by a partly non-parametric approach. Application to HPLC drug assays

    DEFF Research Database (Denmark)

    Linnet, Kristian

    2005-01-01

    Bootstrap, HPLC, limit of blank, limit of detection, non-parametric statistics, type I and II errors......Bootstrap, HPLC, limit of blank, limit of detection, non-parametric statistics, type I and II errors...

  7. Detection limits for real-time source water monitoring using indigenous freshwater microalgae

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Jr, Miguel [ORNL; Greenbaum, Elias [ORNL

    2009-01-01

    This research identified toxin detection limits using the variable fluorescence of naturally occurring microalgae in source drinking water for five chemical toxins with different molecular structures and modes of toxicity. The five chemicals investigated were atrazine, Diuron, paraquat, methyl parathion, and potassium cyanide. Absolute threshold sensitivities of the algae for detection of the toxins in unmodified source drinking water were measured. Differential kinetics between the rate of action of the toxins and natural changes in algal physiology, such as diurnal photoinhibition, are significant enough that effects of the toxin can be detected and distinguished from the natural variance. This is true even for physiologically impaired algae where diminished photosynthetic capacity may arise from uncontrollable external factors such as nutrient starvation. Photoinhibition induced by high levels of solar radiation is a predictable and reversible phenomenon that can be dealt with using a period of dark adaption of 30 minutes or more.

  8. Limits of 2D-TCA in detecting BOLD responses to epileptic activity.

    Science.gov (United States)

    Khatamian, Yasha Borna; Fahoum, Firas; Gotman, Jean

    2011-05-01

    Two-dimensional temporal clustering analysis (2D-TCA) is a relatively new functional MRI (fMRI) based technique that breaks blood oxygen level dependent activity into separate components based on timing and has shown potential for localizing epileptic activity independently of electroencephalography (EEG). 2D-TCA has only been applied to detect epileptic activity in a few studies and its limits in detecting activity of various forms (i.e. activation size, amplitude, and frequency) have not been investigated. This study evaluated 2D-TCA's ability to detect various forms of both simulated epileptic activity and EEG-fMRI activity detected in patients. When applied to simulated data, 2D-TCA consistently detected activity in 6min runs containing 5 spikes/run, 10 spikes/run, and one 5s long event with hemodynamic response function amplitudes of at least 1.5%, 1.25%, and 1% above baseline respectively. When applied to patient data, while detection of interictal spikes was inconsistent, 2D-TCA consistently produced results similar to those obtained by EEG-fMRI when at least 2 prolonged interictal events (a few seconds each) occurred during the run. However, even for such cases it was determined that 2D-TCA can only be used to validate localization by other means or to create hypotheses as to where activity may occur, as it also detects changes not caused by epileptic activity. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Detection Limits for Spectro-fluorometry: A Case Study in the Region of Finstersee, Canton Zug, Northern Switzerland

    Science.gov (United States)

    Otz, M. H.; Otz, H. K.; Keller, P.

    2002-05-01

    Synthetic fluorescent dyes, applied below the visual detection limit (< 0.1 mg/L), have been used as tracers of ground water flow paths since the beginning of the 1950s. Since 1965, we have used spectro-fluorometers with photomultipliers to measure low concentrations of fluorescent dyes in ground water in Switzerland. In collaboration with the Engineering Geology Department of the ETH, we have separated uranine at 0.1 ng/L and Na-naphtionate at 1 ng/L from background fluorescence of spring water in the Finstersee region. These values are 10-100 times lower than postulated detection limits in the literature. The use of low dye concentrations prevents a study region from being contaminated by increased background levels due to remnant dye within the aquifer, thereby leaving the region available for future dye tracing studies. Lower detection limits also can solve particular hydraulic problems where conventional methods fail and enhance the possibility for using artificial dyes in environmentally sensitive aquifer settings.

  10. Matrix effect on the detection limit and accuracy in total reflection X-ray fluorescence analysis of trace elements in environmental and biological samples

    International Nuclear Information System (INIS)

    Karjou, J.

    2007-01-01

    The effect of matrix contents on the detection limit of total reflection X-ray fluorescence analysis was experimentally investigated using a set of multielement standard solutions (500 ng/mL of each element) in variable concentrations of NH 4 NO 3 . It was found that high matrix concentration, i.e. 0.1-10% NH 4 NO 3 , had a strong effect on the detection limits for all investigated elements, whereas no effect was observed at lower matrix concentration, i.e. 0-0.1% NH 4 NO 3 . The effect of soil and blood sample masses on the detection limit was also studied. The results showed decreasing the detection limit (in concentration unit, μg/g) with increasing the sample mass. However, the detection limit increased (in mass unit, ng) with increasing sample mass. The optimal blood sample mass of ca. 200 μg was sufficient to improve the detection limit of Se determination by total reflection X-ray fluorescence. The capability of total reflection X-ray fluorescence to analyze different kinds of samples was discussed with respect to the accuracy and detection limits based on certified and reference materials. Direct analysis of unknown water samples from several sources was also presented in this work

  11. Detection limits of Legionella pneumophila in environmental samples after co-culture with Acanthamoeba polyphaga

    Science.gov (United States)

    2013-01-01

    Background The efficiency of recovery and the detection limit of Legionella after co-culture with Acanthamoeba polyphaga are not known and so far no investigations have been carried out to determine the efficiency of the recovery of Legionella spp. by co-culture and compare it with that of conventional culturing methods. This study aimed to assess the detection limits of co-culture compared to culture for Legionella pneumophila in compost and air samples. Compost and air samples were spiked with known concentrations of L. pneumophila. Direct culturing and co-culture with amoebae were used in parallel to isolate L. pneumophila and recovery standard curves for both methods were produced for each sample. Results The co-culture proved to be more sensitive than the reference method, detecting 102-103 L. pneumophila cells in 1 g of spiked compost or 1 m3 of spiked air, as compared to 105-106 cells in 1 g of spiked compost and 1 m3 of spiked air. Conclusions Co-culture with amoebae is a useful, sensitive and reliable technique to enrich L. pneumophila in environmental samples that contain only low amounts of bacterial cells. PMID:23442526

  12. The Impact of Including Below Detection Limit Samples in Post Decommissioning Soil Sample Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hwan; Yim, Man-Sung [KAIST, Daejeon (Korea, Republic of)

    2016-10-15

    To meet the required standards the site owner has to show that the soil at the facility has been sufficiently cleaned up. To do this one must know the contamination of the soil at the site prior to clean up. This involves sampling that soil to identify the degree of contamination. However there is a technical difficulty in determining how much decontamination should be done. The problem arises when measured samples are below the detection limit. Regulatory guidelines for site reuse after decommissioning are commonly challenged because the majority of the activity in the soil at or below the limit of detection. Using additional statistical analyses of contaminated soil after decommissioning is expected to have the following advantages: a better and more reliable probabilistic exposure assessment, better economics (lower project costs) and improved communication with the public. This research will develop an approach that defines an acceptable method for demonstrating compliance of decommissioned NPP sites and validates that compliance. Soil samples from NPP often contain censored data. Conventional methods for dealing with censored data sets are statistically biased and limited in their usefulness. In this research, additional methods are performed using real data from a monazite manufacturing factory.

  13. Hotspot detection using image pattern recognition based on higher-order local auto-correlation

    Science.gov (United States)

    Maeda, Shimon; Matsunawa, Tetsuaki; Ogawa, Ryuji; Ichikawa, Hirotaka; Takahata, Kazuhiro; Miyairi, Masahiro; Kotani, Toshiya; Nojima, Shigeki; Tanaka, Satoshi; Nakagawa, Kei; Saito, Tamaki; Mimotogi, Shoji; Inoue, Soichi; Nosato, Hirokazu; Sakanashi, Hidenori; Kobayashi, Takumi; Murakawa, Masahiro; Higuchi, Tetsuya; Takahashi, Eiichi; Otsu, Nobuyuki

    2011-04-01

    Below 40nm design node, systematic variation due to lithography must be taken into consideration during the early stage of design. So far, litho-aware design using lithography simulation models has been widely applied to assure that designs are printed on silicon without any error. However, the lithography simulation approach is very time consuming, and under time-to-market pressure, repetitive redesign by this approach may result in the missing of the market window. This paper proposes a fast hotspot detection support method by flexible and intelligent vision system image pattern recognition based on Higher-Order Local Autocorrelation. Our method learns the geometrical properties of the given design data without any defects as normal patterns, and automatically detects the design patterns with hotspots from the test data as abnormal patterns. The Higher-Order Local Autocorrelation method can extract features from the graphic image of design pattern, and computational cost of the extraction is constant regardless of the number of design pattern polygons. This approach can reduce turnaround time (TAT) dramatically only on 1CPU, compared with the conventional simulation-based approach, and by distributed processing, this has proven to deliver linear scalability with each additional CPU.

  14. Thermal ionization mass spectrometry (TIMS) of actinides: Pushing the limits of accuracy and detection

    Energy Technology Data Exchange (ETDEWEB)

    Buerger, Stefan; Boulyga, Sergei; Cunningham, Alan; Klose, Dilani; Koepf, Andreas; Poths, Jane [Safeguards Analytical Laboratory, International Atomic Energy Agency, Vienna (Austria); Richter, Stephan [Institute for Reference Materials and Measurements, JRC-EU, Geel (Belgium)

    2010-07-01

    New method developments in multi-collector thermal ionization mass spectrometry (MC-TIMS) for actinide isotope ratio analysis to improve accuracy and limits of detection will be presented. With respect to limits of detection, results on improving work function using various carbon additives will be reviewed and presented as well as developments in cavity ion source (as compared to standard flat ribbon filament ion source) for femto- and attogram levels of uranium, plutonium, and americium. With respect to accuracy, results on isotope ratio measurements of isotopes of uranium (relative accuracy of 0.3% to 0.01%) are presented with an example being U-234-Th-230 age-dating (NBL CRM 112-A). In this context, the importance of traceability (to the S.I. units) and the use of (certified) reference materials are emphasized. The focus of this presentation is on applications to nuclear safeguards / forensics.

  15. Flexible Modeling of Survival Data with Covariates Subject to Detection Limits via Multiple Imputation.

    Science.gov (United States)

    Bernhardt, Paul W; Wang, Huixia Judy; Zhang, Daowen

    2014-01-01

    Models for survival data generally assume that covariates are fully observed. However, in medical studies it is not uncommon for biomarkers to be censored at known detection limits. A computationally-efficient multiple imputation procedure for modeling survival data with covariates subject to detection limits is proposed. This procedure is developed in the context of an accelerated failure time model with a flexible seminonparametric error distribution. The consistency and asymptotic normality of the multiple imputation estimator are established and a consistent variance estimator is provided. An iterative version of the proposed multiple imputation algorithm that approximates the EM algorithm for maximum likelihood is also suggested. Simulation studies demonstrate that the proposed multiple imputation methods work well while alternative methods lead to estimates that are either biased or more variable. The proposed methods are applied to analyze the dataset from a recently-conducted GenIMS study.

  16. Evaluation on the detection limit of blood hemoglobin using photolepthysmography based on path-length optimization

    Science.gov (United States)

    Sun, Di; Guo, Chao; Zhang, Ziyang; Han, Tongshuai; Liu, Jin

    2016-10-01

    The blood hemoglobin concentration's (BHC) measurement using Photoplethysmography (PPG), which gets blood absorption to near infrared light from the instantaneous pulse of transmitted light intensity, has not been applied to the clinical use due to the non-enough precision. The main challenge might be caused of the non-enough stable pulse signal when it's very weak and it often varies in different human bodies or in the same body with different physiological states. We evaluated the detection limit of BHC using PPG as the measurement precision level, which can be considered as a best precision result because we got the relative stable subject's pulse signals recorded by using a spectrometer with high signal-to-noise ratio (SNR) level, which is about 30000:1 in short term. Moreover, we optimized the used pathlength using the theory based on optimum pathlength to get a better sensitivity to the absorption variation in blood. The best detection limit was evaluated as about 1 g/L for BHC, and the best SNR of pulse for in vivo measurement was about 2000:1 at 1130 and 1250 nm. Meanwhile, we conclude that the SNR of pulse signal should be better than 400:1 when the required detection limit is set to 5 g/L. Our result would be a good reference to the BHC measurement to get a desired BHC measurement precision of real application.

  17. Limits on surface gravities of Kepler planet-candidate host stars from non-detection of solar-like oscillations

    Energy Technology Data Exchange (ETDEWEB)

    Campante, T. L.; Chaplin, W. J.; Handberg, R.; Miglio, A.; Davies, G. R.; Elsworth, Y. P. [School of Physics and Astronomy, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Lund, M. N.; Arentoft, T.; Christensen-Dalsgaard, J.; Karoff, C.; Kjeldsen, H.; Lundkvist, M. [Stellar Astrophysics Centre (SAC), Department of Physics and Astronomy, Aarhus University, Ny Munkegade 120, DK-8000 Aarhus C (Denmark); Huber, D. [NASA Ames Research Center, MS 244-30, Moffett Field, CA 94035 (United States); Hekker, S. [Astronomical Institute, " Anton Pannekoek," University of Amsterdam, Amsterdam (Netherlands); García, R. A. [Laboratoire AIM, CEA/DSM-CNRS-Université Paris Diderot (France); IRFU/SAp, Centre de Saclay, F-91191 Gif-sur-Yvette Cedex (France); Corsaro, E. [Instituut voor Sterrenkunde, KU Leuven, Celestijnenlaan 200D, B-3001 Leuven (Belgium); Basu, S. [Department of Astronomy, Yale University, New Haven, CT 06520 (United States); Bedding, T. R. [Sydney Institute for Astronomy, School of Physics, University of Sydney, Sydney (Australia); Gilliland, R. L. [Center for Exoplanets and Habitable Worlds, The Pennsylvania State University, University Park, PA 16802 (United States); Kawaler, S. D., E-mail: campante@bison.ph.bham.ac.uk [Department of Physics and Astronomy, Iowa State University, Ames, IA 50011 (United States); and others

    2014-03-10

    We present a novel method for estimating lower-limit surface gravities (log g) of Kepler targets whose data do not allow the detection of solar-like oscillations. The method is tested using an ensemble of solar-type stars observed in the context of the Kepler Asteroseismic Science Consortium. We then proceed to estimate lower-limit log g for a cohort of Kepler solar-type planet-candidate host stars with no detected oscillations. Limits on fundamental stellar properties, as provided by this work, are likely to be useful in the characterization of the corresponding candidate planetary systems. Furthermore, an important byproduct of the current work is the confirmation that amplitudes of solar-like oscillations are suppressed in stars with increased levels of surface magnetic activity.

  18. Detection Limits for Nanoscale Biosensors

    National Research Council Canada - National Science Library

    Sheehan, Paul E; Whitman, Lloyd J

    2005-01-01

    We examine through analytical calculations and finite element simulations how the detection efficiency of disk and wire-like biosensors in unmixed fluids varies with size from the micrometer to nanometer scales...

  19. Invasive Acer negundo outperforms native species in non-limiting resource environments due to its higher phenotypic plasticity.

    Science.gov (United States)

    Porté, Annabel J; Lamarque, Laurent J; Lortie, Christopher J; Michalet, Richard; Delzon, Sylvain

    2011-11-24

    To identify the determinants of invasiveness, comparisons of traits of invasive and native species are commonly performed. Invasiveness is generally linked to higher values of reproductive, physiological and growth-related traits of the invasives relative to the natives in the introduced range. Phenotypic plasticity of these traits has also been cited to increase the success of invasive species but has been little studied in invasive tree species. In a greenhouse experiment, we compared ecophysiological traits between an invasive species to Europe, Acer negundo, and early- and late-successional co-occurring native species, under different light, nutrient availability and disturbance regimes. We also compared species of the same species groups in situ, in riparian forests. Under non-limiting resources, A. negundo seedlings showed higher growth rates than the native species. However, A. negundo displayed equivalent or lower photosynthetic capacities and nitrogen content per unit leaf area compared to the native species; these findings were observed both on the seedlings in the greenhouse experiment and on adult trees in situ. These physiological traits were mostly conservative along the different light, nutrient and disturbance environments. Overall, under non-limiting light and nutrient conditions, specific leaf area and total leaf area of A. negundo were substantially larger. The invasive species presented a higher plasticity in allocation to foliage and therefore in growth with increasing nutrient and light availability relative to the native species. The higher level of plasticity of the invasive species in foliage allocation in response to light and nutrient availability induced a better growth in non-limiting resource environments. These results give us more elements on the invasiveness of A. negundo and suggest that such behaviour could explain the ability of A. negundo to outperform native tree species, contributes to its spread in European resource

  20. Picomolar detection limits with current-polarized Pb2+ ion-selective membranes.

    Science.gov (United States)

    Pergel, E; Gyurcsányi, R E; Tóth, K; Lindner, E

    2001-09-01

    Minor ion fluxes across ion-selective membranes bias submicromolar activity measurements with conventional ion-selective electrodes. When ion fluxes are balanced, the lower limit of detection is expected to be dramatically improved. As proof of principle, the flux of lead ions across an ETH 5435 ionophore-based lead-selective membrane was gradually compensated by applying a few nanoamperes of galvanostatic current. When the opposite ion fluxes were matched, and the undesirable leaching of primary ions was eliminated, Nernstian response down to 3 x 10(-12) M was achieved.

  1. The study on the lidar's detection limit for Iodine Gas

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong-lyul; Baik, Seung-Hoon; Park, Seung-Kyu; Park, Nak-Gyu; Ahn, Yong-Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    A powerful and reliable tool for range-resolved remote sensing of gas concentrations that has proven its capabilities in a variety of studies is the differential absorption lidar (DIAL). Differential absorption lidar (DIAL) is frequently used for atmospheric gas monitoring to detect impurities such as nitrogen dioxide, sulfur dioxide, iodine, and ozone. DIAL can measure air pollutant concentrations with a high spatial resolution by adopting two laser systems with different degrees of absorption between the two different wavelengths. The absorption of the reference wavelength is very weak, while the absorption of the other wavelength is very strong. In this paper, we measured the limit of detection capability of our designed DIAL system. The DIAL measurements were performed using a target iodine cell in the laboratory. We confirmed that the concentration of iodine gas ratio increased after the laser passed through the iodine cell. The system of DIAL(Differential Absorption Lidar) was effective to detect the iodine gas. We obtained the signals from the iodine target cell and the lidar signal from the iodine target cell was proportional to frequency locking ratios.

  2. First direct detection limits on sub-GeV dark matter from XENON10.

    Science.gov (United States)

    Essig, Rouven; Manalaysay, Aaron; Mardon, Jeremy; Sorensen, Peter; Volansky, Tomer

    2012-07-13

    The first direct detection limits on dark matter in the MeV to GeV mass range are presented, using XENON10 data. Such light dark matter can scatter with electrons, causing ionization of atoms in a detector target material and leading to single- or few-electron events. We use 15  kg day of data acquired in 2006 to set limits on the dark-matter-electron scattering cross section. The strongest bound is obtained at 100 MeV where σ(e)dark-matter masses between 20 MeV and 1 GeV are bounded by σ(e)dark-matter candidates with masses well below the GeV scale.

  3. The ground fault detection system for the Tore Supra toroidal pump limiter

    International Nuclear Information System (INIS)

    Zunino, K.; Cara, P.; Fejoz, P.; Hourtoule, J.; Loarer, T.; Pomaro, N.; Santagiustina, A.; Spuig, P.; Villecroze, F.

    2003-01-01

    The toroidal pump limiter (TPL) of Tore Supra is electrically insulated from the vacuum-vessel, to allow its polarization at a voltage of up to 1 kV. In order to monitor continuously the integrity of the TPL electrical insulation, an electronic diagnostic system called TPL ground fault detection system (GFDS) has been developed. The paper will report on the design and the operation experience of the GFD system and on the evolution of the TPL grounding

  4. Physiological techniques for detecting expiratory flow limitation during tidal breathing

    Directory of Open Access Journals (Sweden)

    N.G. Koulouris

    2011-09-01

    Full Text Available Patients with severe chronic obstructive pulmonary disease (COPD often exhale along the same flow–volume curve during quiet breathing as they do during the forced expiratory vital capacity manoeuvre, and this has been taken as an indicator of expiratory flow limitation at rest (EFLT. Therefore, EFLT, namely attainment of maximal expiratory flow during tidal expiration, occurs when an increase in transpulmonary pressure causes no increase in expiratory flow. EFLT leads to small airway injury and promotes dynamic pulmonary hyperinflation, with concurrent dyspnoea and exercise limitation. In fact, EFLT occurs commonly in COPD patients (mainly in Global Initiative for Chronic Obstructive Lung Disease III and IV stage, in whom the latter symptoms are common, but is not exclusive to COPD, since it can also be detected in other pulmonary and nonpulmonary diseases like asthma, acute respiratory distress syndrome, heart failure and obesity, etc. The existing up to date physiological techniques of assessing EFLT are reviewed in the present work. Among the currently available techniques, the negative expiratory pressure has been validated in a wide variety of settings and disorders. Consequently, it should be regarded as a simple, noninvasive, practical and accurate new technique.

  5. Diamond-based electrochemical aptasensor realizing a femtomolar detection limit of bisphenol A.

    Science.gov (United States)

    Ma, Yibo; Liu, Junsong; Li, Hongdong

    2017-06-15

    In this study, we designed and fabricated an electrochemical impedance aptasensor based on Au nanoparticles (Au-NPs) coated boron-doped diamond (BDD) modified with aptamers, and 6-mercapto-1-hexanol (MCH) for the detection of bisphenol A (BPA). The constructed BPA aptasensor exhibits good linearity from 1.0×10 -14 to 1.0×10 -9 molL -1 . The detection limitation of 7.2×10 -15 molL -1 was achieved, which can be attributed to the synergistic effect of combining BDD with Au-NPs, aptamers, and MCH. The examine results of BPA traces in Tris-HCl buffer and in milk, UV spectra of aptamer/BPA and interference test revealed that the novel aptasensors are of high sensitivity, specificity, stability and repeatability, which could be promising in practical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Improved sensitivity and limit-of-detection of lateral flow devices using spatial constrictions of the flow-path.

    Science.gov (United States)

    Katis, Ioannis N; He, Peijun J W; Eason, Robert W; Sones, Collin L

    2018-05-03

    We report on the use of a laser-direct write (LDW) technique that allows the fabrication of lateral flow devices with enhanced sensitivity and limit of detection. This manufacturing technique comprises the dispensing of a liquid photopolymer at specific regions of a nitrocellulose membrane and its subsequent photopolymerisation to create impermeable walls inside the volume of the membrane. These polymerised structures are intentionally designed to create fluidic channels which are constricted over a specific length that spans the test zone within which the sample interacts with pre-deposited reagents. Experiments were conducted to show how these constrictions alter the fluid flow rate and the test zone area within the constricted channel geometries. The slower flow rate and smaller test zone area result in the increased sensitivity and lowered limit of detection for these devices. We have quantified these via the improved performance of a C-Reactive Protein (CRP) sandwich assay on our lateral flow devices with constricted flow paths which demonstrate an improvement in its sensitivity by 62x and in its limit of detection by 30x when compared to a standard lateral flow CRP device. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  7. Limit of detection for the determination of Pt in biological material by RNAA using electrolytic separation of gold

    International Nuclear Information System (INIS)

    Xilei, L.; Heydorn, K.; Rietz, B.

    1992-01-01

    Neutron activation analysis based on the 199 Au indicator for platinum requires the separation of gold at high radiochemical purity. The limit of detection is strongly affected by the presence of gold; with a gold content of 50 pg/g, irradiating for 5 days at 5*10 13 n/cm 2 is needed to achieve a limit of detection of approximately 30 pg/g. In this case the nuclear interference from gold will exceeded the level of platium by several orders of magnitude and has to be determined with exceedingly high precision. Preliminary results for SRM 1577 Bovine Liver with 95% yield gave consistent results for Au, but Pt could not be detected. (author) 23 refs.; 3 figs.; 4 tabs

  8. Detection limits of pollutants in water for PGNAA using Am-Be source

    International Nuclear Information System (INIS)

    Khelifi, R.; Amokrane, A.; Bode, P.

    2007-01-01

    A basic PGNAA facility with an Am-Be neutron source is described to analyze the pollutants in water. The properties of neutron flux were determined by MCNP calculations. In order to determine the efficiency curve of a HPGe detector, the prompt-gamma rays from chlorine were used and an exponential curve was fitted. The detection limits for typical water sample are also estimated using the statistical fluctuations of the background level in the areas of recorded the prompt-gamma spectrum

  9. Enhanced detection of gametocytes by magnetic deposition microscopy predicts higher potential for Plasmodium falciparum transmission

    Directory of Open Access Journals (Sweden)

    Zborowski Maciej

    2008-04-01

    Full Text Available Abstract Background Aggregated haemozoin crystals within malaria-infected erythrocytes confer susceptibility of parasitized cells to a magnetic field. Here the utility of this method for diagnosis of human malaria is evaluated in a malaria-endemic region of Papua New Guinea (PNG. Methods and findings Individuals with Plasmodium falciparum malaria symptoms (n = 55 provided samples for conventional blood smear (CBS and magnetic deposition microscopy (MDM diagnosis. Standard Giemsa staining and light microscopy was performed to evaluate all preparations. Plasmodium falciparum parasitaemia observed on MDM slides was consistently higher than parasitaemia observed by (CBS for ring (CBS = 2.6 vs. MDM = 3.4%; t-test P-value = 0.13, trophozoite (CBS = 0.5 vs. MDM = 1.6%; t-test P-value = 0.01, schizont (CBS = 0.003 vs. MDM = 0.1%; t-test P-value = 0.08 and gametocyte (CBS = 0.001 vs. MDM = 0.4%; t-test P-value = 0.0002 parasitaemias. Gametocyte prevalence determined by CBS compared to MDM increased from 7.3% to 45%, respectively. Conclusion MDM increased detection sensitivity of P. falciparum-infected, haemozoin-containing erythrocytes from infected humans while maintaining detection of ring-stage parasites. Gametocyte prevalence five-fold higher than observed by CBS suggests higher malaria transmission potential in PNG endemic sites compared to previous estimates.

  10. ROBUST ESTIMATION OF MEAN AND VARIANCE USING ENVIRONMENTAL DATA SETS WITH BELOW DETECTION LIMIT OBSERVATIONS

    Science.gov (United States)

    Scientists, especially environmental scientists often encounter trace level concentrations that are typically reported as less than a certain limit of detection, L. Type 1, left-censored data arise when certain low values lying below L are ignored or unknown as they cannot be mea...

  11. Detecting terrestrial nutrient limitation: a global meta-analysis of foliar nutrient concentrations after fertilization

    Directory of Open Access Journals (Sweden)

    Rebecca eOstertag

    2016-03-01

    Full Text Available Examining foliar nutrient concentrations after fertilization provides an alternative method for detecting nutrient limitation of ecosystems, which is logistically simpler to measure than biomass change. We present a meta-analysis of response ratios of foliar nitrogen and phosphorus (RRN, RRP after addition of fertilizer of nitrogen (N, phosphorus (P, or the two elements in combination, in relation to climate, ecosystem type, life form, family, and methodological factors. Results support other meta-analyses using biomass, and demonstrate there is strong evidence for nutrient limitation in natural communities. However, because N fertilization experiments greatly outnumber P fertilization trials, it is difficult to discern the absolute importance of N vs. P vs. co-limitation across ecosystems. Despite these caveats, it is striking that results did not follow conventional wisdom that temperate ecosystems are N-limited and tropical ones are P-limited. In addition, the use of ratios of N-to-P rather than response ratios also are a useful index of nutrient limitation, but due to large overlap in values, there are unlikely to be universal cutoff values for delimiting N vs. P limitation. Differences in RRN and RRP were most significant across ecosystem types, plant families, life forms, and between competitive environments, but not across climatic variables.

  12. Analysis of detection limit to time-resolved coherent anti-Stokes Raman scattering nanoscopy

    International Nuclear Information System (INIS)

    Liu Wei; Liu Shuang-Long; Chen Dan-Ni; Niu Han-Ben

    2014-01-01

    In the implementation of CARS nanoscopy, signal strength decreases with focal volume size decreasing. A crucial problem that remains to be solved is whether the reduced signal generated in the suppressed focal volume can be detected. Here reported is a theoretical analysis of detection limit (DL) to time-resolved CARS (T-CARS) nanoscopy based on our proposed additional probe-beam-induced phonon depletion (APIPD) method for the low concentration samples. In order to acquire a detailed shot-noise limited signal-to-noise (SNR) and the involved parameters to evaluate DL, the T-CARS process is described with full quantum theory to estimate the extreme power density levels of the pump and Stokes beams determined by saturation behavior of coherent phonons, which are both actually on the order of ∼ 10 9 W/cm 2 . When the pump and Stokes intensities reach such values and the total intensity of the excitation beams arrives at a maximum tolerable by most biological samples in a certain suppressed focal volume (40-nm suppressed focal scale in APIPD method), the DL correspondingly varies with exposure time, for example, DL values are 10 3 and 10 2 when exposure times are 20 ms and 200 ms respectively. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  13. Use of environmental TLD data at a nuclear power station to estimate detection limits for radiation exposure due to station operation

    International Nuclear Information System (INIS)

    Lang, E.; Hardeman, J.; Kahn, B.

    1987-01-01

    The environmental radiation monitoring network maintained by the Georgia Department of Natural Resources at the Hatch Nuclear Plant, Baxley, GA, was used to determine the variability in measured background exposures in order to estimate the detection limits for radiation due to station operation. Data were obtained from LiF thermoluminescent dosimeters (TLDs) exposed in sets of four at 46 locations for 16 consecutive quarters from 1982 to 1985. The average exposure for 695 values was 11.8 microC kg-1 y-1 (mR/quarter). At individual locations, the averages of quarterly exposures ranged from 9.3 to 14.3 microC kg-1 y-1 and had standard deviations from 0.8 to 2.2 microC kg-1 y-1 with a typical standard deviation of 1.5 microC kg-1 y-1. The standard deviation due to reading the TLDs and subtracting the transit plus storage exposure, estimated as 0.4 microC kg-1 y-1, contributed only a small fraction of the uncertainty of the mean background; the greater contribution is from temporal fluctuations. There is a spatial pattern of higher background along the Altamaha River but no distinct seasonal pattern. The observation that exposure values at most locations rose and fell in unison suggested a calculational model that adjusts the average exposure level at a location by an increment determined each quarter at control locations. This model reduced the standard deviation for a predicted quarterly background exposure to 0.9 microC kg-1 y-1, with a range of 0.5 to 1.3 microC kg-1 y-1. If the standard deviation of the net value is multiplied by an error probability constant of 3.3 (type I and II errors not greater than 5%), the detection limits range from 2 to 5 microC kg-1 y-1 at the individual locations, with an average of 3 microC kg-1 y-1. This approach or two similar ones described earlier are recommended for improving the detection limit where needed

  14. New limits on the detection of a composition-dependent macroscopic force

    International Nuclear Information System (INIS)

    Boynton, P.; Aronson, S.

    1990-01-01

    We report here on a continuing experimental search for a macroscopic, composition dependent force coupling to ordinary matter. Within the phenomenological framework commonly employed -- a Yukawa representation of the interaction potential, and composition specified as some linear combination of baryon and lepton numbers -- the Index 3 experiment sets the most stringent upper limits yet on the interaction strength for coupling from B-2L to B-L, and for an interaction range from 200 m to 10 km. It is also the first null result to conflict with the marginal detection reported for the Index 1 experiment for all relevant values of the composition and range parameters

  15. Molecular techniques for detection and identification of pathogens in food: advantages and limitations

    OpenAIRE

    Palomino-Camargo, Carolina; Instituto de Ciencia y Tecnología de Alimentos, Facultad de Ciencias, Universidad Central de Venezuela. Caracas, Venezuela. Magíster en Ciencia y Tecnología de los Alimentos licenciada en Biología; González-Muñoz, Yuniesky; Instituto de Ciencia y Tecnología de Alimentos, Facultad de Ciencias, Universidad Central de Venezuela. Caracas, Venezuela. Ministerio del Poder Popular para la Alimentación. Caracas, Venezuela. licenciado en Ciencias de los Alimentos.

    2014-01-01

    Foodborne diseases, caused by pathogenic microorganisms, are a major public health problem worldwide. Microbiological methods commonly used in the detection of these foodborne pathogens are laborious and time consuming. This situation, coupled with the demand for immediate results and with technological advances, has led to the development of a wide range of rapid methods in recent decades. On this basis, this review describes the advantages and limitations of the main molecular methods used ...

  16. Evaluation of the limits of visual detection of image misregistration in a brain fluorine-18 fluorodeoxyglucose PET-MRI study

    International Nuclear Information System (INIS)

    Wong, J.C.H.; Studholme, C.; Hawkes, D.J.; Maisey, M.N.

    1997-01-01

    In routine clinical work, registration accuracy is assessed by visual inspection. However, the accuracy of visual assessment of registration has not been evaluated. This study establishes the limits of visual detection of misregistration in a registered brain fluorine-18 fluorodeoxyglucose positron emission tomography to magnetic resonance image volume. The ''best'' registered image volume was obtained by automatic registration using mutual information optimization. Translational movements by 1 mm, 2 mm, 3 mm and 4 mm, and rotational movements by 1 , 2 , 3 and 4 in the positive and negative directions in the x- (lateral), y- (anterior-posterior) and z- (axial) axes were introduced to this standard. These 48 images plus six ''best'' registered images were presented in random sequence to five observers for visual categorization of registration accuracy. No observer detected a definite misregistration in the ''best'' registered image. Evaluation for inter-observer variation using observer pairings showed a high percentage of agreement in assigned categories for both translational and rotational misregistrations. Assessment of the limits of detection of misregistration showed that a 2-mm translational misregistration was detectable by all observers in the x- and y-axes and 3-mm translational misregistration in the z-axis. With rotational misregistrations, rotation around the z-axis was detectable by all at 2 rotation whereas rotation around the y-axis was detected at 3-4 . Rotation around the x-axis was not symmetric with a positive rotation being identified at 2 whereas negative rotation was detected by all only at 4 . Therefore, visual analysis appears to be a sensitive and practical means to assess image misregistration accuracy. The awareness of the limits of visual detection of misregistration will lead to increase care when evaluating registration quality in both research and clinical settings. (orig.). With 6 figs., 3 tabs

  17. Analysis of uncertainties and detection limits for the double measurement method of {sup 90}Sr and {sup 89}Sr

    Energy Technology Data Exchange (ETDEWEB)

    Herranz, M., E-mail: m.herranz@ehu.es [Department of Nuclear Engineering and Fluid Mechanics, University of the Basque Country (UPV/EHU), Alameda de Urquijo s/n 48013 Bilbao (Spain); Idoeta, R.; Legarda, F. [Department of Nuclear Engineering and Fluid Mechanics, University of the Basque Country (UPV/EHU), Alameda de Urquijo s/n 48013 Bilbao (Spain)

    2011-08-15

    The determination process of the {sup 90}Sr and {sup 89}Sr contents in a sample, although it involves their radiochemical isolation, results always in a complex measurement process due to the interferences among their respective beta emissions and also among those of the daughter of {sup 90}Sr, {sup 90}Y, a beta emitter as well. In this paper, the process consisting in a double measurement method after the Sr radiochemical isolation is analyzed, developing the formulae to obtain activity concentrations, uncertainties and detection limits. A study of the trend of uncertainties and detection limits as function of the time in which the first measurement since the isolation is done, the delay between the two measurements and the activity concentration of each strontium isotope in the sample is carried out as well. Results show that with a very precise determination of the times involved in the whole process (isolation, measurement and duration of measurements) this method permits a reliable assessment of both strontium radioisotopes. The quicker the first measurement since the isolation is done and the longer the delay between measurements is chosen, the lower are the detection limits and the uncertainties of the activities obtained. - Highlights: > The double measurement method for {sup 90}Sr and {sup 89}Sr determination is analysed. > Uncertainties and detection limits are determined and their dependences studied. > Proposals for the optimization of the method are given.

  18. Lower limit of detection: definition and elaboration of a proposed position for radiological effluent and environmental measurements

    International Nuclear Information System (INIS)

    Currie, L.A.

    1984-09-01

    A manual is provided to define and illustrate a proposed use of the Lower Limit of Detection (LLD) for Radiological Effluent and Environmental Measurements. The manual contains a review of information regarding LLD practices gained from site visits; a review of the literature and a summary of basic principles underlying the concept of detection in Nuclear and Analytical Chemistry; a detailed presentation of the application of LLD principles to a range of problem categories (simple counting to multinuclide spectroscopy), including derivations, equations, and numerical examples; and a brief examination of related issues such as reference samples, numerical quality control, and instrumental limitations. An appendix contains a summary of notation and terminology, a bibliography, and worked-out examples. 100 references, 10 figures, 7 tables

  19. Amorphous semiconductors for particle detection: Physical and technical limits and possibilities

    International Nuclear Information System (INIS)

    Equer, B.; Karar, A.

    1989-01-01

    Amorphous silicon is used, at an industrial level, in at least three different fields of application: photovoltaic cells, flat TV screens and line scanners for image processing. In the last two cases, thin film transistors (TFT) are produced with the same technology. Particle detection with amorphous silicon has been demonstrated, but present performances are limited to ionizing particles. In this paper, we discuss the physical basis of amorphous semiconductors and the possible future development that can be expected on the basis of the existing technology. It is concluded that substitution of amorphous for crystalline silicon brings no clear advantage, if possible at all. Positive assets are to be found in using specific properties of thin layers: large area structures like arrays of photodiodes with associated readout are in the state of the art; vertical structures alternating layers of differently doped materials and/or of different semiconductors can be produced by the same technique. The development of large area pixel detectors is technically feasible but requires a very large effort. A joint development effort with industries involved in X-ray detection and 2D photodetectors might be the most appropriate solution. (orig.)

  20. Structural damage detection using higher-order finite elements and a scanning laser vibrometer

    Science.gov (United States)

    Jin, Si

    In contrast to conventional non-destructive evaluation methods, dynamics-based damage detection methods are capable of rapid integrity evaluation of large structures and have received considerable attention from aerospace, mechanical, and civil engineering communities in recent years. However, the identifiable damage size using dynamics-based methods is determined by the number of sensors used, level of measurement noise, accuracy of structural models, and signal processing techniques. In this thesis we study dynamics of structures with damage and then derive and experimentally verify new model-independent structural damage detection methods that can locate small damage to structures. To find sensitive damage detection parameters we develop a higher-order beam element that enforces the continuity of displacements, slopes, bending moments, and shear forces at all nodes, and a higher-order rectangular plate element that enforces the continuity of displacements, slopes, and bending and twisting moments at all nodes. These two elements are used to study the dynamics of beams and plates. Results show that high-order spatial derivatives of high-frequency modes are important sensitive parameters that can locate small structural damage. Unfortunately the most powerful and popular structural modeling technique, the finite element method, is not accurate in predicting high-frequency responses. Hence, a model-independent method using dynamic responses obtained from high density measurements is concluded to be the best approach. To increase measurement density and reduce noise a Polytec PI PSV-200 scanning laser vibrometer is used to provide non-contact, dense, and accurate measurements of structural vibration velocities. To avoid the use of structural models and to extract sensitive detection parameters from experimental data, a brand-new structural damage detection method named BED (Boundary-Effect Detection) is developed for pinpointing damage locations using Operational

  1. A novel dNTP-limited PCR and HRM assay to detect Williams-Beuren syndrome.

    Science.gov (United States)

    Zhang, Lichen; Zhang, Xiaoqing; You, Guoling; Yu, Yongguo; Fu, Qihua

    2018-06-01

    Williams-Beuren syndrome (WBS) is caused by a microdeletion of chromosome arm 7q11.23. A rapid and inexpensive genotyping method to detect microdeletion on 7q11.23 needs to be developed for the diagnosis of WBS. This study describes the development of a new type of molecular diagnosis method to detect microdeletion on 7q11.23 based upon high-resolution melting (HRM). Four genes on 7q11.23 were selected as the target genes for the deletion genotyping. dNTP-limited duplex PCR was used to amplify the reference gene, CFTR, and one of the four genes respectively on 7q11.23. An HRM assay was performed on the PCR products, and the height ratio of the negative derivative peaks between the target gene and reference gene was employed to analyze the copy number variation of the target region. A new genotyping method for detecting 7q11.23 deletion was developed based upon dNTP-limited PCR and HRM, which cost only 96 min. Samples from 15 WBS patients and 12 healthy individuals were genotyped by this method in a blinded fashion, and the sensitivity and specificity was 100% (95% CI, 0.80-1, and 95% CI, 0.75-1, respectively) which was proved by CytoScan HD array. The HRM assay we developed is an rapid, inexpensive, and highly accurate method for genotyping 7q11.23 deletion. It is potentially useful in the clinical diagnosis of WBS. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Neutron activation analysis detection limits using 252Cf sources

    International Nuclear Information System (INIS)

    DiPrete, D.P.; Sigg, R.A.

    2000-01-01

    The Savannah River Technology Center (SRTC) developed a neutron activation analysis (NAA) facility several decades ago using low-flux 252 Cf neutron sources. Through this time, the facility has addressed areas of applied interest in managing the Savannah River Site (SRS). Some applications are unique because of the site's operating history and its chemical-processing facilities. Because sensitivity needs for many applications are not severe, they can be accomplished using an ∼6-mg 252 Cf NAA facility. The SRTC 252 Cf facility continues to support applied research programs at SRTC as well as other SRS programs for environmental and waste management customers. Samples analyzed by NAA include organic compounds, metal alloys, sediments, site process solutions, and many other materials. Numerous radiochemical analyses also rely on the facility for production of short-lived tracers, yielding by activation of carriers and small-scale isotope production for separation methods testing. These applications are more fully reviewed in Ref. 1. Although the flux [approximately2 x 10 7 n/cm 2 ·s] is low relative to reactor facilities, more than 40 elements can be detected at low and sub-part-per-million levels. Detection limits provided by the facility are adequate for many analytical projects. Other multielement analysis methods, particularly inductively coupled plasma atomic emission and inductively coupled plasma mass spectrometry, can now provide sensitivities on dissolved samples that are often better than those available by NAA using low-flux isotopic sources. Because NAA allows analysis of bulk samples, (a) it is a more cost-effective choice when its sensitivity is adequate than methods that require digestion and (b) it eliminates uncertainties that can be introduced by digestion processes

  3. A program for the a priori evaluation of detection limits in instrumental neutron activation analysis using a SLOWPOKE II reactor

    International Nuclear Information System (INIS)

    Galinier, J.L.; Zikovsky, L.

    1982-01-01

    A program that permits the a priori calculation of detection limits in monoelemental matrices, adapted to instrumental neutron activation analysis using a SLOWPOKE II reactor, is described. A simplified model of the gamma spectra is proposed. Products of (n,p) and (n,α) reactions induced by the fast components of the neutron flux that accompanies the thermal flux at the level of internal irradiation sites in the reactor have been included in the list of interfering radionuclides. The program calculates in a systematic way the detection limits of 66 elements in an equal number of matrices using 153 intermediary radionuclides. Experimental checks carried out with silicon (for short lifetimes) and aluminum and magnesium (for intermediate lifetimes) show satisfactory agreement with the calculations. These results show in particular the importance of the contribution of the (n,p) and (n,α) reactions in the a priori evaluation of detection limits with a SLOWPOKE type reactor [fr

  4. Re-evaluation of groundwater monitoring data for glyphosate and bentazone by taking detection limits into account

    DEFF Research Database (Denmark)

    Hansen, Claus Toni; Ritz, Christian; Gerhard, Daniel

    2015-01-01

    .e. samples with concentrations below the detection limit, as left-censored observations. The median calculated pesticide concentrations are shown to be reduced 10(4) to 10(5) fold for two representative herbicides (glyphosate and bentazone) relative to the median concentrations based upon observations above...

  5. Quantifying Efficacy and Limits of Unmanned Aerial Vehicle (UAV Technology for Weed Seedling Detection as Affected by Sensor Resolution

    Directory of Open Access Journals (Sweden)

    José M. Peña

    2015-03-01

    Full Text Available In order to optimize the application of herbicides in weed-crop systems, accurate and timely weed maps of the crop-field are required. In this context, this investigation quantified the efficacy and limitations of remote images collected with an unmanned aerial vehicle (UAV for early detection of weed seedlings. The ability to discriminate weeds was significantly affected by the imagery spectral (type of camera, spatial (flight altitude and temporal (the date of the study resolutions. The colour-infrared images captured at 40 m and 50 days after sowing (date 2, when plants had 5–6 true leaves, had the highest weed detection accuracy (up to 91%. At this flight altitude, the images captured before date 2 had slightly better results than the images captured later. However, this trend changed in the visible-light images captured at 60 m and higher, which had notably better results on date 3 (57 days after sowing because of the larger size of the weed plants. Our results showed the requirements on spectral and spatial resolutions needed to generate a suitable weed map early in the growing season, as well as the best moment for the UAV image acquisition, with the ultimate objective of applying site-specific weed management operations.

  6. Quantifying efficacy and limits of unmanned aerial vehicle (UAV) technology for weed seedling detection as affected by sensor resolution.

    Science.gov (United States)

    Peña, José M; Torres-Sánchez, Jorge; Serrano-Pérez, Angélica; de Castro, Ana I; López-Granados, Francisca

    2015-03-06

    In order to optimize the application of herbicides in weed-crop systems, accurate and timely weed maps of the crop-field are required. In this context, this investigation quantified the efficacy and limitations of remote images collected with an unmanned aerial vehicle (UAV) for early detection of weed seedlings. The ability to discriminate weeds was significantly affected by the imagery spectral (type of camera), spatial (flight altitude) and temporal (the date of the study) resolutions. The colour-infrared images captured at 40 m and 50 days after sowing (date 2), when plants had 5-6 true leaves, had the highest weed detection accuracy (up to 91%). At this flight altitude, the images captured before date 2 had slightly better results than the images captured later. However, this trend changed in the visible-light images captured at 60 m and higher, which had notably better results on date 3 (57 days after sowing) because of the larger size of the weed plants. Our results showed the requirements on spectral and spatial resolutions needed to generate a suitable weed map early in the growing season, as well as the best moment for the UAV image acquisition, with the ultimate objective of applying site-specific weed management operations.

  7. On the definition of the detection limit for non-selective determination of low activities

    International Nuclear Information System (INIS)

    Tschurlovits, M.

    1977-01-01

    Based on the latest published results, a detection limit which is easy to use in practical work without intensive consideration of counting statistics, is presented. The primary application of the given definition is the determination of gross activity. In the definition the error of the second kind as well as one-sided boundedness of the normal distribution are included. The results are given in graphical form. (orig.) [de

  8. Internal Dosimetry Monitoring- Detection Limits for a Selected Set of Radionuclides and Their Translation Into Committed Effective Dose

    International Nuclear Information System (INIS)

    Brandl, A.; Hrnecek, E.; Steger, F.

    2004-01-01

    To harmonize the practice of internal dosimetry monitoring across the country, the Austrian Standards Institute is currently drafting a new set of standards which are concerned with occupational incorporation monitoring of individuals handling non-sealed radioactive material. This set of standards is expected to consist of three parts discussing the general necessity and frequency, the requirements for monitoring institutions, and the determination and rigorous calculation of committed effective dose after incorporation of radioactive material, respectively. Considerations of the requirements for routine monitoring laboratories have led to an evaluation of the detection limits for routine monitoring equipment. For a selected set of radionuclides, these detection limits are investigated in detail. The main emphasis is placed on the decay chains of naturally occurring radionuclides showing some significant potential for being out of equilibrium due to chemical processes in certain mining industries. The radionuclides considered in this paper are 226Ra, 228Ra, 228Th, 232Th, 234U, 235U, and 238U. Given the routine monitoring intervals of the Austrian Standard, these detection limits are translated into information on committed effective dose. This paper investigates whether routine monitoring equipment is sufficient to ensure compliance with EC directive 96/29/Euratom for this selected set of radionuclides. (Author) 9 refs

  9. Comparison of detection limits in environmental analysis--is it possible? An approach on quality assurance in the lower working range by verification.

    Science.gov (United States)

    Geiss, S; Einax, J W

    2001-07-01

    Detection limit, reporting limit and limit of quantitation are analytical parameters which describe the power of analytical methods. These parameters are used for internal quality assurance and externally for competing, especially in the case of trace analysis in environmental compartments. The wide variety of possibilities for computing or obtaining these measures in literature and in legislative rules makes any comparison difficult. Additionally, a host of terms have been used within the analytical community to describe detection and quantitation capabilities. Without trying to create an order for the variety of terms, this paper is aimed at providing a practical proposal for answering the main questions for the analysts concerning quality measures above. These main questions and related parameters were explained and graphically demonstrated. Estimation and verification of these parameters are the two steps to get real measures. A rule for a practical verification is given in a table, where the analyst can read out what to measure, what to estimate and which criteria have to be fulfilled. In this manner verified parameters detection limit, reporting limit and limit of quantitation now are comparable and the analyst himself is responsible to the unambiguity and reliability of these measures.

  10. Improved detection limits for electrospray ionization on a magnetic sector mass spectrometer by using an array detector.

    Science.gov (United States)

    Cody, R B; Tamura, J; Finch, J W; Musselman, B D

    1994-03-01

    Array detection was compared with point detection for solutions of hen egg-white lysozyme, equine myoglobin, and ubiquitin analyzed by electrospray ionization with a magnetic sector mass spectrometer. The detection limits for samples analyzed by using the array detector system were at least 10 times lower than could be achieved by using a point detector on the same mass spectrometer. The minimum detectable quantity of protein corresponded to a signal-to-background ratio of approximately 2∶1 for a 500 amol/μL solution of hen egg-white lysozyme. However, the ultimate practical sample concentrations appeared to be in the 10-100 fmol/μL range for the analysis of dilute solutions of relatively pure proteins or simple mixtures.

  11. DETERMINATION OF LIMIT DETECTION OF THE ELEMENTS N, P, K, Si, Al, Fe, Cu, Cd, WITH FAST NEUTRON ACTIVATION USING NEUTRON GENERATOR

    Directory of Open Access Journals (Sweden)

    Sunardi Sunardi

    2010-06-01

    Full Text Available Determination of limit detection of the elements N, P, K, Si, Al, Fe, Cu, Cd, with fast neutron activation using neutron generator has been done.  Samples prepared from SRM 2704, N, P, K elements from MERCK, Cu, Cd, Al from activation foil made in San Carlos, weighted and packed for certain weight then iradiated during 30 minutes with 14 MeV fast neutron using the neutron generator and then counted with gamma spectrometry (accuspec.  At this research condition of neutron generator was set at current 1 mA that produced neutron flux about 5,47.107 n/cm2.s and  experimental result shown that the limit detection for the elements N, P, K, Si, Al, Fe, Cu, Cd are  2,44 ppm, 1,88 ppm, 2,15 ppm, 1,44 ppm, 1,26 ppm, 1,35 ppm, 1,05 ppm, 2,99 ppm, respectively.  The data  indicate that the limit detection or sensitivity of appliance of neutron generator to analyze the element is very good, which is feasible to get accreditation AANC laboratory using neutron generator.   Keywords: limit detection, AANC, neutron generator

  12. Low-Cost Resonant Cavity Raman Gas Probe for Multi-Gas Detection

    Science.gov (United States)

    Thorstensen, J.; Haugholt, K. H.; Ferber, A.; Bakke, K. A. H.; Tschudi, J.

    2014-12-01

    Raman based gas sensing can be attractive in several industrial applications, due to its multi-gas sensing capabilities and its ability to detect O_2 and N_2. In this article, we have built a Raman gas probe, based on low-cost components, which has shown an estimated detection limit of 0.5 % for 30 second measurements of N_2 and O_2. While this detection limit is higher than that of commercially available equipment, our estimated component cost is approximately one tenth of the price of commercially available equipment. The use of a resonant Fabry-Pérot cavity increases the scattered signal, and hence the sensitivity, by a factor of 50. The cavity is kept in resonance using a piezo-actuated mirror and a photodiode in a feedback loop. The system described in this article was made with minimum-cost components to demonstrate the low-cost principle. However, it is possible to decrease the detection limit using a higher-powered (but still low-cost) laser and improving the collection optics. By applying these improvements, the detection limit and estimated measurement precision will be sufficient for e.g. the monitoring of input gases in combustion processes, such as e.g. (bio-)gas power plants. In these processes, knowledge about gas compositions with 0.1 % (absolute) precision can help regulate and optimize process conditions. The system has the potential to provide a low-cost, industrial Raman sensor that is optimized for specific gas-detection applications.

  13. Generalized linear mixed model for binary outcomes when covariates are subject to measurement errors and detection limits.

    Science.gov (United States)

    Xie, Xianhong; Xue, Xiaonan; Strickler, Howard D

    2018-01-15

    Longitudinal measurement of biomarkers is important in determining risk factors for binary endpoints such as infection or disease. However, biomarkers are subject to measurement error, and some are also subject to left-censoring due to a lower limit of detection. Statistical methods to address these issues are few. We herein propose a generalized linear mixed model and estimate the model parameters using the Monte Carlo Newton-Raphson (MCNR) method. Inferences regarding the parameters are made by applying Louis's method and the delta method. Simulation studies were conducted to compare the proposed MCNR method with existing methods including the maximum likelihood (ML) method and the ad hoc approach of replacing the left-censored values with half of the detection limit (HDL). The results showed that the performance of the MCNR method is superior to ML and HDL with respect to the empirical standard error, as well as the coverage probability for the 95% confidence interval. The HDL method uses an incorrect imputation method, and the computation is constrained by the number of quadrature points; while the ML method also suffers from the constrain for the number of quadrature points, the MCNR method does not have this limitation and approximates the likelihood function better than the other methods. The improvement of the MCNR method is further illustrated with real-world data from a longitudinal study of local cervicovaginal HIV viral load and its effects on oncogenic HPV detection in HIV-positive women. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Applying ISO 11929:2010 Standard to detection limit calculation in least-squares based multi-nuclide gamma-ray spectrum evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kanisch, G., E-mail: guenter.kanisch@hanse.net

    2017-05-21

    The concepts of ISO 11929 (2010) are applied to evaluation of radionuclide activities from more complex multi-nuclide gamma-ray spectra. From net peak areas estimated by peak fitting, activities and their standard uncertainties are calculated by weighted linear least-squares method with an additional step, where uncertainties of the design matrix elements are taken into account. A numerical treatment of the standard's uncertainty function, based on ISO 11929 Annex C.5, leads to a procedure for deriving decision threshold and detection limit values. The methods shown allow resolving interferences between radionuclide activities also in case of calculating detection limits where they can improve the latter by including more than one gamma line per radionuclide. The co'mmon single nuclide weighted mean is extended to an interference-corrected (generalized) weighted mean, which, combined with the least-squares method, allows faster detection limit calculations. In addition, a new grouped uncertainty budget was inferred, which for each radionuclide gives uncertainty budgets from seven main variables, such as net count rates, peak efficiencies, gamma emission intensities and others; grouping refers to summation over lists of peaks per radionuclide.

  15. Analysis of background components in Ge-spectrometry and their influence on detection limits

    Energy Technology Data Exchange (ETDEWEB)

    Heusser, G [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany)

    1997-03-01

    In low radioactivity measurements the system own background of the spectrometer is, besides the counting efficiency, the limiting factor for the achievable sensitivity. Since the latter is mostly fixed, background reduction is the only way to gain sensitivity, although it is inversely proportional only to the square root of the background rate but directly proportional to the counting efficiency. A thorough understanding of the background sources and their quantitative contribution helps to choose the most adequate suppression method in order to reach a certain required level of detection limit. For Ge-spectrometry the background can be reduced by 5 to 6 orders of magnitude compared to the unshielded case applying state-of-the-art techniques. This reduction factor holds for the continuous background spectrum as well as for the line background as demonstrated for a Ge detector of the Heidelberg-Moscow double beta decay experiment. (orig./DG)

  16. WE-H-207A-09: Theoretical Limits to Molecular Biomarker Detection Using Magnetic Nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, J [Dartmouth-Hitchcock Medical Center, Lebanon, NH (United States); Geisel School of Medicine, Dartmouth College, Hanover, NH (United States)

    2016-06-15

    Purpose: Estimate the limits of molecular biomarker detection using magnetic nanoparticle methods like in vivo ELISA. Methods: Magnetic nanoparticles in an alternating magnetic field produce a magnetization that can be detected at exceedingly low levels because the signal at the harmonic frequencies is uniquely produced by the nanoparticles. Because the magnetization can also be used to characterize the nanoparticle rotational freedom, the bound state can be found. If the nanoparticles are coated with molecules that bind the desired biomarker, the rotational freedom reflects the biomarker concentration. The irreducible noise limit is the thermal noise or Johnson noise of the tissue and the contrast that can be measured must be larger than that limit. The contrast produced is a function of the applied field and depends strongly on nanoparticle volume. We have estimated the contrast using a Langevin function of a single composite variable to approximate the full stochastic Langevin equation for nanoparticle dynamics. Results: The thermal noise for a bandwidth reasonable for spectroscopy suggests mid zeptomolar (10–21) to low attomolar (10–18) concentrations can be measured in a volume that is 10cm in scale. The suggested sensitivity is far below the physiologically concentrations of almost all critical biomarkers including cytokines (picomolar), hormones (nanomolar) and heat shock proteins. Conclusion: The sensitivity of in vivo ELISA concentration measurements should be sufficient to measure physiological concentrations of critical biomarkers like cytokines in vivo. Further the sensitivity should be sufficient to measure concentrations of other biomarkers that are six to eight orders of magnitude lower in concentration than immune signaling molecules like cytokines. NIH - 1U54CA151662-01 Department of Radiology.

  17. Lower detectable limit of sulfur by fast neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Shani, G; Cohen, D [Ben-Gurion Univ. of the Negev, Beersheba (Israel). Dept. of Nuclear Engineering

    1976-07-01

    For the purpose of air pollution research, the possibility of fast neutron activation analysis of sulfur was investigated. The only reaction that can be used for this purpose is S/sup 34/(n, p)P/sup 34/. A rabbit system was installed, synchronized with a 150 kV D-T neutron generator and an electronic analysing system. The whole system was operated so that the sample was irradiated for 10 sec and the 2.13 MeV ..gamma..-ray was counted for 10 sec. 5 samples were prepared containing sulfur from 0.5 to 0.1 g. Each measurement lasted 30 min and the activity was plotted as a function of sulfur weight. The relative error is increased very much when the amount of sulfur is below 0.1 g. This is what sets the lower detectable limit. Collection of more than 0.1 g of sulfur even during a long collection time means a very high SO/sub 2/ concentration in the air.

  18. Evaluation of MidIR fibre optic reflectance: Detection limit, reproducibility and binary mixture discrimination

    Science.gov (United States)

    Sessa, Clarimma; Bagán, Héctor; García, José Francisco

    2013-11-01

    MidIR fibre optic reflectance (MidIR-FORS) is a promising analytical technique in the field of science conservation, especially because it is non-destructive. Another advantage of MidIR-FORS is that the obtained information is representative, as a large amount of spectral data can be collected. Although the technique has a high potential and is almost routinely applied, its quality parameters have not been thoroughly studied in the specific application of analysis of artistic materials. The objective of this study is to evaluate the instrumental capabilities of MidIR-FORS for the analysis of artwork materials in terms of detection limit, reproducibility, and mixture characterisation. The study has been focused on oil easel painting and several paints of known composition have been analysed. Paint layers include blue pigments not only because of their important role along art history, but also because their physical and spectroscopic characteristics allow a better evaluation of the MidIR-FORS capabilities. The results of the analysis indicate that MidIR-FORS supplies a signal affected by different factors, such as the optical, morphological and physical properties of the surface, in addition to the composition of materials analysed. Consequently, the detection limits established are relatively high for artistic objects (Prussian blue - PB 2.1-6.5%; Phthalocyanine blue - Pht 6.3-10.2%; synthetic Ultramarine blue - UM 12.1%) and may therefore lead to an incomplete description of the artwork. Reproducibility of the technique over time and across surface has been determined. The results show that the major sources of dispersion are the heterogeneity of the pigments distribution, physical features, and band shape distortions. The total dispersion is around 4% for the most intense bands (oil) and increases up to 26% when weak or overlapped bands are considered (PB, Pht, UM). The application of different pre-treatments (cutoff of fibres absorption, Savizky-Golay smoothing

  19. Cs2AgBiBr6 single-crystal X-ray detectors with a low detection limit

    Science.gov (United States)

    Pan, Weicheng; Wu, Haodi; Luo, Jiajun; Deng, Zhenzhou; Ge, Cong; Chen, Chao; Jiang, Xiaowei; Yin, Wan-Jian; Niu, Guangda; Zhu, Lujun; Yin, Lixiao; Zhou, Ying; Xie, Qingguo; Ke, Xiaoxing; Sui, Manling; Tang, Jiang

    2017-11-01

    Sensitive X-ray detection is crucial for medical diagnosis, industrial inspection and scientific research. The recently described hybrid lead halide perovskites have demonstrated low-cost fabrication and outstanding performance for direct X-ray detection, but they all contain toxic Pb in a soluble form. Here, we report sensitive X-ray detectors using solution-processed double perovskite Cs2AgBiBr6 single crystals. Through thermal annealing and surface treatment, we largely eliminate Ag+/Bi3+ disordering and improve the crystal resistivity, resulting in a detector with a minimum detectable dose rate as low as 59.7 nGyair s-1, comparable to the latest record of 0.036 μGyair s-1 using CH3NH3PbBr3 single crystals. Suppressed ion migration in Cs2AgBiBr6 permits relatively large external bias, guaranteeing efficient charge collection without a substantial increase in noise current and thus enabling the low detection limit.

  20. Investigation of detection limits for diffuse optical tomography systems: II. Analysis of slab and cup geometry for breast imaging.

    Science.gov (United States)

    Ziegler, Ronny; Brendel, Bernhard; Rinneberg, Herbert; Nielsen, Tim

    2009-01-21

    Using a statistical (chi-square) test on simulated data and a realistic noise model derived from the system's hardware we study the performance of diffuse optical tomography systems for fluorescence imaging. We compare the predicted smallest size of detectable lesions at various positions in slab and cup geometry and model how detection sensitivity depends on breast compression and lesion fluorescence contrast. Our investigation shows that lesion detection is limited by relative noise in slab geometry and by absolute noise in cup geometry.

  1. Limit of detection of a fiber optics gyroscope using a super luminescent radiation source

    International Nuclear Information System (INIS)

    Sandoval R, G.E.; Nikolaev, V.A.

    2003-01-01

    The main objective of this work is to establish the dependence of characteristics of the fiber optics gyroscope (FOG) with respect to the parameters of the super luminescent emission source based on doped optical fiber with rare earth elements (Super luminescent Fiber Source, SFS), argument the pumping rate election of the SFS to obtain characteristics limits of the FOG sensibility. By using this type of emission source in the FOG is recommend to use the rate when the direction of the pumping signal coincide with the super luminescent signal. The most results are the proposition and argumentation of the SFS election as emission source to be use in the FOG of the phase type. Such a decision allow to increase the characteristics of the FOG sensibility in comparison with the use of luminescent source of semiconductors emission which are extensively used in the present time. The use of emission source of the SFS type allow to come closer to the threshold of the obtained sensibility limit (detection limit) which is determined with the shot noise. (Author)

  2. Limit of detection of a fiber optics gyroscope using a super luminescent radiation source

    CERN Document Server

    Sandoval, G E

    2003-01-01

    The main objective of this work is to establish the dependence of characteristics of the fiber optics gyroscope (FOG) with respect to the parameters of the super luminescent emission source based on doped optical fiber with rare earth elements (Super luminescent Fiber Source, SFS), argument the pumping rate election of the SFS to obtain characteristics limits of the FOG sensibility. By using this type of emission source in the FOG is recommend to use the rate when the direction of the pumping signal coincide with the super luminescent signal. The most results are the proposition and argumentation of the SFS election as emission source to be use in the FOG of the phase type. Such a decision allow to increase the characteristics of the FOG sensibility in comparison with the use of luminescent source of semiconductors emission which are extensively used in the present time. The use of emission source of the SFS type allow to come closer to the threshold of the obtained sensibility limit (detection limit) which i...

  3. Radioactivity analyses and detection limit problems of environmental surveillance at a gas-cooled reactor

    International Nuclear Information System (INIS)

    Johnson, J.E.; Johnson, J.A.

    1988-01-01

    The lower limit of detection (LLD) values required by the USNRC for nuclear power facilities are often difficult to attain even using state of the art detection systems, e.g. the required LLD for I-131 in air is 70 fCi/m 3 . For a gas-cooled reactor where I-131 has never been observed in effluents, occasional false positive values occur due to: Counting statistics using high resolution Ge(Li) detectors, contamination from nuclear medicine releases and spectrum analysis systematic error. Statistically negative concentration values are often observed. These measurements must be included in the estimation of true mean values. For this and other reasons, the frequency distributions of this and other reasons, the frequency distributions of measured values appear to be log-normal. Difficulties in stating the true means and standard deviations are discussed for these situations

  4. Limited copy number-high resolution melting (LCN-HRM) enables the detection and identification by sequencing of low level mutations in cancer biopsies.

    Science.gov (United States)

    Do, Hongdo; Dobrovic, Alexander

    2009-10-08

    Mutation detection in clinical tumour samples is challenging when the proportion of tumour cells, and thus mutant alleles, is low. The limited sensitivity of conventional sequencing necessitates the adoption of more sensitive approaches. High resolution melting (HRM) is more sensitive than sequencing but identification of the mutation is desirable, particularly when it is important to discriminate false positives due to PCR errors or template degradation from true mutations.We thus developed limited copy number - high resolution melting (LCN-HRM) which applies limiting dilution to HRM. Multiple replicate reactions with a limited number of target sequences per reaction allow low level mutations to be detected. The dilutions used (based on Ct values) are chosen such that mutations, if present, can be detected by the direct sequencing of amplicons with aberrant melting patterns. Using cell lines heterozygous for mutations, we found that the mutations were not readily detected when they comprised 10% of total alleles (20% tumour cells) by sequencing, whereas they were readily detectable at 5% total alleles by standard HRM. LCN-HRM allowed these mutations to be identified by direct sequencing of those positive reactions.LCN-HRM was then used to review formalin-fixed paraffin-embedded (FFPE) clinical samples showing discordant findings between sequencing and HRM for KRAS exon 2 and EGFR exons 19 and 21. Both true mutations present at low levels and sequence changes due to artefacts were detected by LCN-HRM. The use of high fidelity polymerases showed that the majority of the artefacts were derived from the damaged template rather than replication errors during amplification. LCN-HRM bridges the sensitivity gap between HRM and sequencing and is effective in distinguishing between artefacts and true mutations.

  5. Determining the 95% limit of detection for waterborne pathogen analyses from primary concentration to qPCR

    Science.gov (United States)

    Stokdyk, Joel P.; Firnstahl, Aaron; Spencer, Susan K.; Burch, Tucker R; Borchardt, Mark A.

    2016-01-01

    The limit of detection (LOD) for qPCR-based analyses is not consistently defined or determined in studies on waterborne pathogens. Moreover, the LODs reported often reflect the qPCR assay alone rather than the entire sample process. Our objective was to develop an approach to determine the 95% LOD (lowest concentration at which 95% of positive samples are detected) for the entire process of waterborne pathogen detection. We began by spiking the lowest concentration that was consistently positive at the qPCR step (based on its standard curve) into each procedural step working backwards (i.e., extraction, secondary concentration, primary concentration), which established a concentration that was detectable following losses of the pathogen from processing. Using the fraction of positive replicates (n = 10) at this concentration, we selected and analyzed a second, and then third, concentration. If the fraction of positive replicates equaled 1 or 0 for two concentrations, we selected another. We calculated the LOD using probit analysis. To demonstrate our approach we determined the 95% LOD for Salmonella enterica serovar Typhimurium, adenovirus 41, and vaccine-derived poliovirus Sabin 3, which were 11, 12, and 6 genomic copies (gc) per reaction (rxn), respectively (equivalent to 1.3, 1.5, and 4.0 gc L−1 assuming the 1500 L tap-water sample volume prescribed in EPA Method 1615). This approach limited the number of analyses required and was amenable to testing multiple genetic targets simultaneously (i.e., spiking a single sample with multiple microorganisms). An LOD determined this way can facilitate study design, guide the number of required technical replicates, aid method evaluation, and inform data interpretation.

  6. Poor glycemic control of diabetes mellitus is associated with higher risk of prostate cancer detection in a biopsy population.

    Directory of Open Access Journals (Sweden)

    Juhyun Park

    Full Text Available To evaluate the impact of glycemic control of diabetes mellitus (DM on prostate cancer detection in a biopsy population.We retrospectively reviewed the records of 1,368 men who underwent prostate biopsy at our institution. We divided our biopsy population into three groups according to their history of DM, and their Hemoglobin A1c (HbA1c level: a no-DM (DM- group; a good glycemic control (DM+GC group (HbA1c <6.5%; and a poor glycemic control (DM+PC group (HbA1c ≥6.5%. For sub-analyses, the DM+PC group was divided into a moderately poor glycemic control (DM+mPC group (6.5≤ HbA1c <7.5% and a severely poor glycemic control (DM+sPC group (HbA1c ≥7.5%.Among 1,368 men, 338 (24.7% had a history of DM, and 393 (28.7% had a positive biopsy. There was a significant difference in prostatic specific antigen density (PSAD (P = 0.037 and the frequency of abnormal DRE findings (P = 0.031 among three groups. The occurrence rate of overall prostate cancer (P<0.001 and high-grade prostate cancer (P = 0.016 also presented with a significantly difference. In the multivariate analysis, the DM+PC group was significantly associated with a higher rate of overall prostate cancer detection in biopsy subjects compared to the DM- group (OR = 2.313, P = 0.001 but the DM+PC group was not associated with a higher rate of high-grade (Gleason score ≥7 diseases detected during the biopsy (OR = 1.297, P = 0.376. However, in subgroup analysis, DM+sPC group was significantly related to a higher risk of high-grade diseases compared to the DM- group (OR = 2.446, P = 0.048.Poor glycemic control of DM was associated with a higher risk of prostate cancer detection, including high-grade disease, in the biopsy population.

  7. Effects of Kapton Sample Cell Windows on the Detection Limit of Smectite: Implications for CheMin on the Mars Science Laboratory Mission

    Science.gov (United States)

    Achilles, C. N.; Ming, Douglas W.; Morris, R. V.; Blake, D. F.

    2012-01-01

    The CheMin instrument on the Mars Science Laboratory (MSL) rover Curiosity is an X-ray diffraction (XRD) and X-ray fluorescence (XRF) instrument capable of providing the mineralogical and chemical compositions of rocks and soils on the surface of Mars. CheMin uses a microfocus X-ray tube with a Co target, transmission geometry, and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D XRD patterns and energy-dispersive X-ray histograms from powdered samples. CheMin has two different window materials used for sample cells -- Mylar and Kapton. Instrument details are provided elsewhere. Fe/Mg-smectite (e.g., nontronite) has been identified in Gale Crater, the MSL future landing site, by CRISM spectra. While large quantities of phyllosilicate minerals will be easily detected by CheMin, it is important to establish detection limits of such phases to understand capabilities and limitations of the instrument. A previous study indicated that the (001) peak of smectite at 15 Ang was detectable in a mixture of 1 wt.% smectite with olivine when Mylar is the window material for the sample cell. Complications arise when Kapton is the window material because Kapton itself also has a diffraction peak near 15 Ang (6.8 deg 2 Theta). This study presents results of mineral mixtures of smectite and olivine to determine smectite detection limits for Kapton sample cells. Because the intensity and position of the smectite (001) peak depends on the hydration state, we also analyzed mixtures with "hydrated" and "dehydrated"h smectite to examine the effects of hydration state on detection limits.

  8. Improved detection limit for {sup 59}Ni using the technique of accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Persson, Per; Erlandsson, Bengt; Hellborg, Ragnar; Kiisk, Madis; Larsson, Ragnar; Skog, Goeran; Stenstroem, Kristina [Lund Univ. (Sweden). Dept. of Nuclear Physics

    2002-11-01

    59 Ni is produced by neutron activation in the stainless steel close to the core of a nuclear reactor. To be able to classify the different parts of the reactor with respect to their content of long-lived radionuclides before final storage it is important to measure the 59 Ni level. Accelerator mass spectrometry is an ultra-sensitive method for counting atoms, suitable for 59 Ni measurements. Improvements in the reduction of the background and in the chemical reduction of cobalt, the interfering isobar, have been made. This chemical purification is essential when using small tandem accelerators, <3 MV, combined with the detection of characteristic projectile X-rays. These improvements have lowered the detection limit for 59 Ni by a factor of twenty compared with the first value reported for the Lund AMS facility. Material from the Swedish nuclear industry has been analysed and examples of the results are presented.

  9. Electrochemical Detection with Preconcentration: Nitroenergetic Contaminants

    Directory of Open Access Journals (Sweden)

    Brandy J. Johnson

    2014-06-01

    Full Text Available This effort evaluated the potential of two prototype devices for enhanced electrochemical detection of 2,4,6-trinitrotoluene (TNT and dinitrotoluene (DNT following preconcentration using an organosilicate sorbent. The bench-scale prototype provides adsorption of the targets from aqueous solution followed by elution in a mixture of methanol and potassium chloride (KCl. Following elution, the eluant is diluted using an aqueous KCl solution to provide sufficient electrolyte for electrochemical analysis. Concentrations of methanol greater than 50% were detrimental to sensor performance and lifetime. Calibration of the electrochemical sensor was completed and results of electrochemical analysis were compared to those of HPLC analysis over a range of concentrations and in varied matrices. TNT detection was found to be consistent and detection limits were improved from 200 ppb to 3 ppb depending on the sample volume utilized. DNT detection showed higher variability and significantly greater false response rates. On the basis of these results, a second, more advanced, prototype was developed and utilized in limited field trials with the intention of moving the technology toward in situ applications.

  10. Nanotechnology for Early Cancer Detection

    Directory of Open Access Journals (Sweden)

    Joon Won Park

    2010-01-01

    Full Text Available Vast numbers of studies and developments in the nanotechnology area have been conducted and many nanomaterials have been utilized to detect cancers at early stages. Nanomaterials have unique physical, optical and electrical properties that have proven to be very useful in sensing. Quantum dots, gold nanoparticles, magnetic nanoparticles, carbon nanotubes, gold nanowires and many other materials have been developed over the years, alongside the discovery of a wide range of biomarkers to lower the detection limit of cancer biomarkers. Proteins, antibody fragments, DNA fragments, and RNA fragments are the base of cancer biomarkers and have been used as targets in cancer detection and monitoring. It is highly anticipated that in the near future, we might be able to detect cancer at a very early stage, providing a much higher chance of treatment.

  11. Thermal background noise limitations

    Science.gov (United States)

    Gulkis, S.

    1982-01-01

    Modern detection systems are increasingly limited in sensitivity by the background thermal photons which enter the receiving system. Expressions for the fluctuations of detected thermal radiation are derived. Incoherent and heterodyne detection processes are considered. References to the subject of photon detection statistics are given.

  12. Detection limits in the chromatographic element trace analysis - quantitative TLC, HPLC and GC with the example of beryllium acetylacetonate

    International Nuclear Information System (INIS)

    Schwedt, G.

    1981-01-01

    Chromatographic analyses of beryllium acetylacetonate are carried out in synthetic solutions within the nano- and picogram range of beryllium. For thin-layer chromatography (TLC) normal and silanized silica gel is used, for high-performance liquid chromatography (HPLC) silica gel of 7 μm particles, for gas chromatography (GC) silicone SE-30 as stationary phase. Visual evaluation and remission measurements in TLC, UV-254 nm absorption measurements in HPLC and measurements with a FID in GC are employed for the determination of the calibration curves. A calibration curve through the origin and a detection limit of 150 pg Be determinable form are received by HPLC only. For trace analyses by GC a new definition of a detection limit for the evaluation of substance peaks on a solvent tailing is suggested. (orig.) [de

  13. Estimation of the limit of detection in semiconductor gas sensors through linearized calibration models.

    Science.gov (United States)

    Burgués, Javier; Jiménez-Soto, Juan Manuel; Marco, Santiago

    2018-07-12

    The limit of detection (LOD) is a key figure of merit in chemical sensing. However, the estimation of this figure of merit is hindered by the non-linear calibration curve characteristic of semiconductor gas sensor technologies such as, metal oxide (MOX), gasFETs or thermoelectric sensors. Additionally, chemical sensors suffer from cross-sensitivities and temporal stability problems. The application of the International Union of Pure and Applied Chemistry (IUPAC) recommendations for univariate LOD estimation in non-linear semiconductor gas sensors is not straightforward due to the strong statistical requirements of the IUPAC methodology (linearity, homoscedasticity, normality). Here, we propose a methodological approach to LOD estimation through linearized calibration models. As an example, the methodology is applied to the detection of low concentrations of carbon monoxide using MOX gas sensors in a scenario where the main source of error is the presence of uncontrolled levels of humidity. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. The value and limitation thallium scintigraphy in the detection of coronary artery disease

    International Nuclear Information System (INIS)

    Khan, A.; Rehman, A.; Amin, W.; Khan, Z.A.; Ahmed, S.A.

    1986-01-01

    In this study we randomly selected 45 patients whose coronary angiograms were abnormal i.e. showing triple, double and single vessel disease out of a pool of 80 patients who had undergone stress thallium imaging and coronary angiography during the one year. Majority of these patients were males, their ages ranged between 34-54 years. Resting ECG's were normal in 25 patients, 15 patients had suffered inferior myocardial infraction and 5 had sustained anterior myocardial infraction in the past. Coronary angiography revealed triple vessel disease in 20 patients, double vessel disease in 15, and single vessel coronary artery disease in 10. We analysed their coronary angiograms and compared them with the scintigraphic finding. It is concluded that although thallium scanning has high sensitivity for detection of coronary artery disease in general, it has only moderate sensitivity for detection of stenosis in individual coronary arteries. In this study thallium scan identified 75% of RCA lesions, 66% of LAD lesions and 38% of circumflex lesions. The sensitivity is much higher in single vessel coronary artery disease. (author)

  15. Higher dimensional time-energy entanglement

    International Nuclear Information System (INIS)

    Richart, Daniel Lampert

    2014-01-01

    Judging by the compelling number of innovations based on taming quantum mechanical effects, such as the development of transistors and lasers, further research in this field promises to tackle further technological challenges in the years to come. This statement gains even more importance in the information processing scenario. Here, the growing data generation and the correspondingly higher need for more efficient computational resources and secure high bandwidth networks are central problems which need to be tackled. In this sense, the required CPU minituarization makes the design of structures at atomic levels inevitable, as foreseen by Moore's law. From these perspectives, it is necessary to concentrate further research efforts into controlling and manipulating quantum mechanical systems. This enables for example to encode quantum superposition states to tackle problems which are computationally NP hard and which therefore cannot be solved efficiently by classical computers. The only limitation affecting these solutions is the low scalability of existing quantum systems. Similarly, quantum communication schemes are devised to certify the secure transmission of quantum information, but are still limited by a low transmission bandwidth. This thesis follows the guideline defined by these research projects and aims to further increase the scalability of the quantum mechanical systems required to perform these tasks. The method used here is to encode quantum states into photons generated by spontaneous parametric down-conversion (SPDC). An intrinsic limitation of photons is that the scalability of quantum information schemes employing them is limited by the low detection efficiency of commercial single photon detectors. This is addressed by encoding higher dimensional quantum states into two photons, increasing the scalability of the scheme in comparison to multi-photon states. Further on, the encoding of quantum information into the emission-time degree of

  16. Higher dimensional time-energy entanglement

    Energy Technology Data Exchange (ETDEWEB)

    Richart, Daniel Lampert

    2014-07-08

    Judging by the compelling number of innovations based on taming quantum mechanical effects, such as the development of transistors and lasers, further research in this field promises to tackle further technological challenges in the years to come. This statement gains even more importance in the information processing scenario. Here, the growing data generation and the correspondingly higher need for more efficient computational resources and secure high bandwidth networks are central problems which need to be tackled. In this sense, the required CPU minituarization makes the design of structures at atomic levels inevitable, as foreseen by Moore's law. From these perspectives, it is necessary to concentrate further research efforts into controlling and manipulating quantum mechanical systems. This enables for example to encode quantum superposition states to tackle problems which are computationally NP hard and which therefore cannot be solved efficiently by classical computers. The only limitation affecting these solutions is the low scalability of existing quantum systems. Similarly, quantum communication schemes are devised to certify the secure transmission of quantum information, but are still limited by a low transmission bandwidth. This thesis follows the guideline defined by these research projects and aims to further increase the scalability of the quantum mechanical systems required to perform these tasks. The method used here is to encode quantum states into photons generated by spontaneous parametric down-conversion (SPDC). An intrinsic limitation of photons is that the scalability of quantum information schemes employing them is limited by the low detection efficiency of commercial single photon detectors. This is addressed by encoding higher dimensional quantum states into two photons, increasing the scalability of the scheme in comparison to multi-photon states. Further on, the encoding of quantum information into the emission-time degree of

  17. Experimental Demonstration of Higher Precision Weak-Value-Based Metrology Using Power Recycling

    Science.gov (United States)

    Wang, Yi-Tao; Tang, Jian-Shun; Hu, Gang; Wang, Jian; Yu, Shang; Zhou, Zong-Quan; Cheng, Ze-Di; Xu, Jin-Shi; Fang, Sen-Zhi; Wu, Qing-Lin; Li, Chuan-Feng; Guo, Guang-Can

    2016-12-01

    The weak-value-based metrology is very promising and has attracted a lot of attention in recent years because of its remarkable ability in signal amplification. However, it is suggested that the upper limit of the precision of this metrology cannot exceed that of classical metrology because of the low sample size caused by the probe loss during postselection. Nevertheless, a recent proposal shows that this probe loss can be reduced by the power-recycling technique, and thus enhance the precision of weak-value-based metrology. Here we experimentally realize the power-recycled interferometric weak-value-based beam-deflection measurement and obtain the amplitude of the detected signal and white noise by discrete Fourier transform. Our results show that the detected signal can be strengthened by power recycling, and the power-recycled weak-value-based signal-to-noise ratio can surpass the upper limit of the classical scheme, corresponding to the shot-noise limit. This work sheds light on higher precision metrology and explores the real advantage of the weak-value-based metrology over classical metrology.

  18. Installation of high-resolution ERDA in UTTAC at the University of Tsukuba: Determination of the energy resolution and the detection limit for hydrogen

    Energy Technology Data Exchange (ETDEWEB)

    Sekiba, D., E-mail: sekiba@tac.tsukuba.ac.jp [Institute of Applied Physics, University of Tsukuba, Tennodai 1-1-1, Tsukuba, Ibaraki 305-8573 (Japan); University of Tsukuba, Tandem Accelerator Complex (UTTAC), Tennodai 1-1-1, Tsukuba, Ibaraki 305-8577 (Japan); Chito, K.; Harayama, I. [Institute of Applied Physics, University of Tsukuba, Tennodai 1-1-1, Tsukuba, Ibaraki 305-8573 (Japan); Watahiki, Y.; Ishii, S. [University of Tsukuba, Tandem Accelerator Complex (UTTAC), Tennodai 1-1-1, Tsukuba, Ibaraki 305-8577 (Japan); Ozeki, K. [Department of Mechanical Engineering, Ibaraki University, Nakanarusawa 4-12-1, Hitachi, Ibaraki 316-8511 (Japan)

    2017-06-15

    A newly developed high-resolution elastic recoil detection analysis (HERDA) system installed at the 1 MV Tandetron in UTTAC at the University of Tsukuba is introduced. The effective solid angle of detector, energy resolution and detection limit for hydrogen are, for the first time, determined quantitatively by the measurements on an a-C:H (and D) film deposited on a Si substrate. In the case of a 500 keV {sup 16}O{sup +} as the incident beam, an energy resolution of ∼0.45 keV and a detection limit of ∼3.8 × 10{sup 20} atoms/cm{sup 3} (∼0.18 at.%) with a data acquisition time of ∼310 s are derived.

  19. Current limitations and challenges in nanowaste detection, characterisation and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Part, Florian; Zecha, Gudrun [Department of Water-Atmosphere-Environment, University of Natural Resources and Life Sciences, Institute of Waste Management, Muthgasse 107, 1190 Vienna (Austria); Causon, Tim [Department of Chemistry, Division of Analytical Chemistry, University of Natural Resources and Life Sciences, Muthgasse 18, 1190 Vienna (Austria); Sinner, Eva-Kathrin [Department of Nanobiotechnology, Institute for Synthetic Bioarchitectures, University of Natural Resources and Life Sciences, Muthgasse 11/II, 1190 Vienna (Austria); Huber-Humer, Marion, E-mail: marion.huber-humer@boku.ac.at [Department of Water-Atmosphere-Environment, University of Natural Resources and Life Sciences, Institute of Waste Management, Muthgasse 107, 1190 Vienna (Austria)

    2015-09-15

    Highlights: • First review on detection of nanomaterials in complex waste samples. • Focus on nanoparticles in solid, liquid and gaseous waste samples. • Summary of current applicable methods for nanowaste detection and characterisation. • Limitations and challenges of characterisation of nanoparticles in waste. - Abstract: Engineered nanomaterials (ENMs) are already extensively used in diverse consumer products. Along the life cycle of a nano-enabled product, ENMs can be released and subsequently accumulate in the environment. Material flow models also indicate that a variety of ENMs may accumulate in waste streams. Therefore, a new type of waste, so-called nanowaste, is generated when end-of-life ENMs and nano-enabled products are disposed of. In terms of the precautionary principle, environmental monitoring of end-of-life ENMs is crucial to allow assessment of the potential impact of nanowaste on our ecosystem. Trace analysis and quantification of nanoparticulate species is very challenging because of the variety of ENM types that are used in products and low concentrations of nanowaste expected in complex environmental media. In the framework of this paper, challenges in nanowaste characterisation and appropriate analytical techniques which can be applied to nanowaste analysis are summarised. Recent case studies focussing on the characterisation of ENMs in waste streams are discussed. Most studies aim to investigate the fate of nanowaste during incineration, particularly considering aerosol measurements; whereas, detailed studies focusing on the potential release of nanowaste during waste recycling processes are currently not available. In terms of suitable analytical methods, separation techniques coupled to spectrometry-based methods are promising tools to detect nanowaste and determine particle size distribution in liquid waste samples. Standardised leaching protocols can be applied to generate soluble fractions stemming from solid wastes, while

  20. Intrinsic spatial resolution limitations due to differences between positron emission position and annihilation detection localization

    International Nuclear Information System (INIS)

    Perez, Pedro; Malano, Francisco; Valente, Mauro

    2012-01-01

    Since its successful implementation for clinical diagnostic, positron emission tomography (PET) represents the most promising medical imaging technique. The recent major growth of PET imaging is mainly due to its ability to trace the biologic pathways of different compounds in the patient's body, assuming the patient can be labeled with some PET isotope. Regardless of the type of isotope, the PET imaging method is based on the detection of two 511-keV gamma photons being emitted in opposite directions, with almost 180 deg between them, as a consequence of electron-positron annihilation. Therefore, this imaging method is intrinsically limited by random uncertainties in spatial resolutions, related with differences between the actual position of positron emission and the location of the detected annihilation. This study presents an approach with the Monte Carlo method to analyze the influence of this effect on different isotopes of potential implementation in PET. (author)

  1. Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits

    Directory of Open Access Journals (Sweden)

    Peeyush Sahay

    2009-10-01

    Full Text Available Breath analysis, a promising new field of medicine and medical instrumentation, potentially offers noninvasive, real-time, and point-of-care (POC disease diagnostics and metabolic status monitoring. Numerous breath biomarkers have been detected and quantified so far by using the GC-MS technique. Recent advances in laser spectroscopic techniques and laser sources have driven breath analysis to new heights, moving from laboratory research to commercial reality. Laser spectroscopic detection techniques not only have high-sensitivity and high-selectivity, as equivalently offered by the MS-based techniques, but also have the advantageous features of near real-time response, low instrument costs, and POC function. Of the approximately 35 established breath biomarkers, such as acetone, ammonia, carbon dioxide, ethane, methane, and nitric oxide, 14 species in exhaled human breath have been analyzed by high-sensitivity laser spectroscopic techniques, namely, tunable diode laser absorption spectroscopy (TDLAS, cavity ringdown spectroscopy (CRDS, integrated cavity output spectroscopy (ICOS, cavity enhanced absorption spectroscopy (CEAS, cavity leak-out spectroscopy (CALOS, photoacoustic spectroscopy (PAS, quartz-enhanced photoacoustic spectroscopy (QEPAS, and optical frequency comb cavity-enhanced absorption spectroscopy (OFC-CEAS. Spectral fingerprints of the measured biomarkers span from the UV to the mid-IR spectral regions and the detection limits achieved by the laser techniques range from parts per million to parts per billion levels. Sensors using the laser spectroscopic techniques for a few breath biomarkers, e.g., carbon dioxide, nitric oxide, etc. are commercially available. This review presents an update on the latest developments in laser-based breath analysis.

  2. 3D versus 2D Systematic Transrectal Ultrasound-Guided Prostate Biopsy: Higher Cancer Detection Rate in Clinical Practice

    Directory of Open Access Journals (Sweden)

    Alexandre Peltier

    2013-01-01

    Full Text Available Objectives. To compare prostate cancer detection rates of extended 2D versus 3D biopsies and to further assess the clinical impact of this method in day-to-day practice. Methods. We analyzed the data of a cohort of 220 consecutive patients with no prior history of prostate cancer who underwent an initial prostate biopsy in daily practice due to an abnormal PSA and/or DRE using, respectively, the classical 2D and the new 3D systems. All the biopsies were done by a single experienced operator using the same standardized protocol. Results. There was no significant difference in terms of age, total PSA, or prostate volume between the two groups. However, cancer detection rate was significantly higher using the 3D versus the 2D system, 50% versus 34% (P<0.05. There was no statistically significant difference while comparing the 2 groups in term of nonsignificant cancer detection. Conclusion. There is reasonable evidence demonstrating the superiority of the 3D-guided biopsies in detecting prostate cancers that would have been missed using the 2D extended protocol.

  3. Potentials and Limitations of Real-Time Elastography for Prostate Cancer Detection: A Whole-Mount Step Section Analysis

    Directory of Open Access Journals (Sweden)

    Daniel Junker

    2012-01-01

    Full Text Available Objectives. To evaluate prostate cancer (PCa detection rates of real-time elastography (RTE in dependence of tumor size, tumor volume, localization and histological type. Materials and Methods. Thirdy-nine patients with biopsy proven PCa underwent RTE before radical prostatectomy (RPE to assess prostate tissue elasticity, and hard lesions were considered suspicious for PCa. After RPE, the prostates were prepared as whole-mount step sections and were compared with imaging findings for analyzing PCa detection rates. Results. RTE detected 6/62 cancer lesions with a maximum diameter of 0–5 mm (9.7%, 10/37 with a maximum diameter of 6–10 mm (27%, 24/34 with a maximum diameter of 11–20 20 mm (70.6%, 14/14 with a maximum diameter of >20 mm (100% and 40/48 with a volume ≥0.2 cm3 (83.3%. Regarding cancer lesions with a volume ≥ 0.2 cm³ there was a significant difference in PCa detection rates between Gleason scores with predominant Gleason pattern 3 compared to those with predominant Gleason pattern 4 or 5 (75% versus 100%; P=0.028. Conclusions. RTE is able to detect PCa of significant tumor volume and of predominant Gleason pattern 4 or 5 with high confidence, but is of limited value in the detection of small cancer lesions.

  4. Comparison of sensitivities and detection limits between direct excitation and secondary excitation modes in energy dispersive x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Artz, B.E.; Short, M.A.

    1976-01-01

    A comparison was made between the direct tube excitation mode and the secondary target excitation mode using a Kevex 0810 energy dispersive x-ray fluorescence system. Relative sensitivities and detection limits were determined with two system configurations. The first configuration used a standard, high power, x-ray fluorescence tube to directly excite the specimen. Several x-ray tubes, including chromium, molybdenum, and tungsten, both filtered and not filtered, were employed. The second configuration consisted of using the x-ray tube to excite a secondary target which in turn excited the specimen. Appropriate targets were compared to the direct excitation results. Relative sensitivities and detection limits were determined for K-series lines for elements from magnesium to barium contained in a low atomic number matrix and in a high atomic number matrix

  5. Collaborative study of a qualitative TLC-method for detection of antioxidants (BHA, BHT, gallates and NDGA) in food

    DEFF Research Database (Denmark)

    Guldborg, Merethe

    1981-01-01

    -proposed method, and an official French method. After extraction, the compounds are detected by TLC. Being a qualitative method the probability of obtaining correct results is a measure of the goodness of the method, and the study examines the influence on the probability of the following 3 factors: type...... of antioxidant, type of food, and concentration of antioxidant. From the study is was concluded that the method worked quite well for BHA, with a detection limit about 15 mg/kg, whereas it worked badly for BHT, the detection limit being higher than 30 mg/kg. For the gallates and NDGA the detection limit was 30...

  6. Scheme for efficient extraction of low-frequency signal beyond the quantum limit by frequency-shift detection.

    Science.gov (United States)

    Yang, R G; Zhang, J; Zhai, Z H; Zhai, S Q; Liu, K; Gao, J R

    2015-08-10

    Low-frequency (Hz~kHz) squeezing is very important in many schemes of quantum precision measurement. But it is more difficult than that at megahertz-frequency because of the introduction of laser low-frequency technical noise. In this paper, we propose a scheme to obtain a low-frequency signal beyond the quantum limit from the frequency comb in a non-degenerate frequency and degenerate polarization optical parametric amplifier (NOPA) operating below threshold with type I phase matching by frequency-shift detection. Low-frequency squeezing immune to laser technical noise is obtained by a detection system with a local beam of two-frequency intense laser. Furthermore, the low-frequency squeezing can be used for phase measurement in Mach-Zehnder interferometer, and the signal-to-noise ratio (SNR) can be enhanced greatly.

  7. Experimental study to optimize time resolution and detection limit of online 222Rn-in-water measurements

    International Nuclear Information System (INIS)

    Just, G.; Freyer, K.; Treutler, H.C.; Philipsborn, H. von

    2001-01-01

    The possibility to detect short-term variations of the activity concentration of 222 Rn in water by online monitoring with temporal resolutions of a few minutes and a lower limit of detection of about 1 Bq/l enhances the applicability of such measurements. New applications would be possible in the field of hydro-geology in which Rn is used as tracer gas, the monitoring of pumping procedures, for the study of exchange processes during groundwater sampling and for various applications with geophysical effects. A suitable, simple method is the measuring principle proposed by Surbeck (Fribourg) some years ago which is based on the separation of air and water by a diffusion membrane. Process parameters enhancing the time resolution of the method as well as the efficiency of different radon detectors have been studied. (orig.) [de

  8. Effect of sample matrix composition on INAA sample weights, measurement precisions, limits of detection, and optimum conditions

    International Nuclear Information System (INIS)

    Guinn, V.P.; Nakazawa, L.; Leslie, J.

    1984-01-01

    The instrumental neutron activation analysis (INAA) Advance Prediction Computer Program (APCP) is extremely useful in guiding one to optimum subsequent experimental analyses of samples of all types of matrices. By taking into account the contributions to the cumulative Compton-continuum levels from all significant induced gamma-emitting radionuclides, it provides good INAA advance estimates of detectable photopeaks, measurement precisions, concentration lower limits of detection (LOD's) and optimum irradiation/decay/counting conditions - as well as of the very important maximum allowable sample size for each set of conditions calculated. The usefulness and importance of the four output parameters cited in the title are discussed using the INAA APCP outputs for NBS SRM-1632 Coal as the example

  9. Is interstellar detection of higher members of the linear radicals CnCH and CnN feasible?

    Science.gov (United States)

    Pauzat, F.; Ellinger, Y.; Mclean, A. D.

    1991-01-01

    Rotational constants and dipole moments for linear-chain radicals CnCH and CnN are estimated using a combinatiaon of ab initio molecular orbital calculations and observed data on the starting members of the series. CnCH with n = 0-5 have been observed by radioastronomy in carbon-rich interstellar clouds; higher members of the series have 2Pi ground states with large dipole moments and are strong candidates for observation. CN and C3N have also been observed by radioastronomy; higher members of the series, with the possible exception of C5N, have 2Pi ground states with near-zero dipole moments making their interstellar detection hopeless under present observational conditions. C5N can be a strong candidate only if it has a 2Sigma ground state, and best computations so far indicate that this is not the case.

  10. Left ventricular time volume curve analysis in the detection of limited ischaemic heart disease

    International Nuclear Information System (INIS)

    Liechtenstein, M.; Blanchett, W.; Andrews, J.; Hunt, D.

    1982-01-01

    The aim of the study was to determine whether limited coronary artery disease (CAD) could be accurately detected using the Cardiac Gated Blood Pool (CGBP) scan with exercise. Regional left ventricular time volume curves (RLTVD) were generated from 52 studies (46 patients: 22 normals, 24 abnormals). The parameters assessed both globally and regionally and at rest (R) and exercise (Ex) were: (1) the ejection fraction (EF) (2) the change in ejection fraction from R to Ex (δEF) (3) an early contraction index (ECI) (4) a maximal emptying index (DR) and (5) a maximal refilling index (AR). After careful analysis of these parameters it was decided that our diagnostic criteria would rely on the following: (1) the EF at R and Ex (2) the δ EF (3) the ECI at Ex (4) the AR at Ex This study showed that both the sensitivity and the specificity of the CGBP scan can be improved considerably with the inclusion of RLTVC from the levels obtained when the EF parameters alone are considered. It is possible with this technique to accurately diagnose limited CAD. (Author)

  11. Doppler Radar Vital Signs Detection Method Based on Higher Order Cyclostationary.

    Science.gov (United States)

    Yu, Zhibin; Zhao, Duo; Zhang, Zhiqiang

    2017-12-26

    Due to the non-contact nature, using Doppler radar sensors to detect vital signs such as heart and respiration rates of a human subject is getting more and more attention. However, the related detection-method research meets lots of challenges due to electromagnetic interferences, clutter and random motion interferences. In this paper, a novel third-order cyclic cummulant (TOCC) detection method, which is insensitive to Gaussian interference and non-cyclic signals, is proposed to investigate the heart and respiration rate based on continuous wave Doppler radars. The k -th order cyclostationary properties of the radar signal with hidden periodicities and random motions are analyzed. The third-order cyclostationary detection theory of the heart and respiration rate is studied. Experimental results show that the third-order cyclostationary approach has better estimation accuracy for detecting the vital signs from the received radar signal under low SNR, strong clutter noise and random motion interferences.

  12. Improved detection limits for phthalates by selective solid-phase micro-extraction

    KAUST Repository

    Zia, Asif I.

    2016-03-30

    Presented research reports on an improved method and enhanced limits of detection for phthalates; a hazardous additive used in the production of plastics by solid-phase micro-extraction (SPME) polymer in comparison to molecularly imprinted solid-phase extraction (MISPE) polymer. The polymers were functionalized on an interdigital capacitive sensor for selective binding of phthalate molecules from a complex mixture of chemicals. Both polymers owned predetermined selectivity by formation of valuable molecular recognition sites for Bis (2-ethylhexyl) phthalate (DEHP). Polymers were immobilized on planar electrochemical sensor fabricated on a single crystal silicon substrate with 500 nm sputtered gold electrodes fabricated using MEMS fabrication techniques. Impedance spectra were obtained using electrochemical impedance spectroscopy (EIS) to determine sample conductance for evaluation of phthalate concentration in the spiked sample solutions with various phthalate concentrations. Experimental results revealed that the ability of SPME polymer to adsorb target molecules on the sensing surface is better than that of MISPE polymer for phthalates in the sensing system. Testing the extracted samples using high performance liquid chromatography with photodiode array detectors validated the results.

  13. The value and limitations of contrast-enhanced transrectal ultrasonography for the detection of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Han-Xue, E-mail: zhaohx861@163.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Xia, Chun-Xia, E-mail: star9901482@163.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Yin, Hong-Xia, E-mail: hongxia_yin79@yahoo.com.cn [Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Guo, Ning, E-mail: ningguo99@sina.com.cn [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Zhu, Qiang, E-mail: qzhutrhos@gmail.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China)

    2013-11-01

    Objectives: To evaluate the role of contrast-enhanced transrectal ultrasonography (CE-TRUS) for detecting prostate carcinoma. Methods: Sixty-five patients with elevated serum prostate-specific antigen (PSA) and/or abnormal digital rectal examination (DRE) were assessed using transrectal ultrasound (TRUS) and CE-TRUS. In all the patients, CE-TRUS was performed with intravenous injection of contrast agent (SonoVue, 2.4 ml) before biopsy. The cancer detection rates of the two techniques were compared. False-positive and false-negative findings related to CE-TRUS were analyzed in comparison to the pathological results of biopsy or radical prostatectomy. The targeted biopsy to abnormal CE-TRUS areas was also compared to systematic biopsy. Results: Prostate cancer was detected in 29 of the 65 patients. CE-TRUS showed rapid focal enhancement or asymmetric vessels of peripheral zones in 28 patients; 23 of them had prostate cancer. CE-TRUS had 79.3% sensitivity, compared to 65.5% of TRUS (P < 0.05). There were five false-positive and six false-negative findings from CE-TRUS. Benign prostate hyperplasia, and acute and chronic prostatitis were important causes related to the false-positive results of CE-TRUS. Prostate cancer originating from the transition zone or peripheral zone with lower PSA levels, small-size foci, and moderately or well-differentiated tumor was missed by CE-TRUS. The cancer detection rate of targeted biopsy (75%, 33/44 cores) was significantly higher than one of systematic biopsy (48.2%, 162/336) in those 28 cases (P < 0.05). In addition, no significant correlation was found between the cancer detection rate with CE-TRUS and serum PSA levels. Conclusion: CE-TRUS may improve the detection rate of prostate cancer through targeted biopsy of contrast-enhanced abnormalities. Our findings indicate that systematic biopsies should not be eliminated on the basis of false-positive and false-negative findings related to CE-TRUS.

  14. 40 CFR Appendix C to Part 425 - Definition and Procedure for the Determination of the Method Detection Limit 1

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Definition and Procedure for the Determination of the Method Detection Limit 1 C Appendix C to Part 425 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE...

  15. Confocal laser-induced fluorescence detector for narrow capillary system with yoctomole limit of detection.

    Science.gov (United States)

    Weaver, Mitchell T; Lynch, Kyle B; Zhu, Zaifang; Chen, Huang; Lu, Joann J; Pu, Qiaosheng; Liu, Shaorong

    2017-04-01

    Laser-induced fluorescence (LIF) detectors for low-micrometer and sub-micrometer capillary on-column detection are not commercially available. In this paper, we describe in details how to construct a confocal LIF detector to address this issue. We characterize the detector by determining its limit of detection (LOD), linear dynamic range (LDR) and background signal drift; a very low LOD (~70 fluorescein molecules or 12 yoctomole fluorescein), a wide LDR (greater than 3 orders of magnitude) and a small background signal drift (~1.2-fold of the root mean square noise) are obtained. For detecting analytes inside a low-micrometer and sub-micrometer capillary, proper alignment is essential. We present a simple protocol to align the capillary with the optical system and use the position-lock capability of a translation stage to fix the capillary in position during the experiment. To demonstrate the feasibility of using this detector for narrow capillary systems, we build a 2-μm-i.d. capillary flow injection analysis (FIA) system using the newly developed LIF prototype as a detector and obtain an FIA LOD of 14 zeptomole fluorescein. We also separate a DNA ladder sample by bare narrow capillary - hydrodynamic chromatography and use the LIF prototype to monitor the resolved DNA fragments. We obtain not only well-resolved peaks but also the quantitative information of all DNA fragments. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Study of higher hydrocarbon production during ethylacetylene pyrolysis using laser-generated vacuum-ultraviolet photoionization detection

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, J.; Pfefferle, L. (Yale Univ., New Haven, CT (USA))

    1990-04-19

    Higher hydrocarbon formation during the pyrolysis of ethylacetylene in a microjet reactor was studied by vacuum-ultraviolet photoionization time-of-flight mass spectrometry. At the wavelength employed, this ionization technique allows for the simultaneous detection of both stable and intermediate polyatomic species with ionization potentials below 10.49 eV, including most hydrocarbons with two or more carbon atoms. Minimal fragmentation simplifies the determination of parent species and allows identification of probable reaction pathways involving hydrocarbon radicals as well as stable species. The pyrolysis of ethylacetylene was carried out in the fast-flow microjet reactor (residence times 1-2 ms) at temperatures from 300 to 1,600 K.

  17. Is interstellar detection of higher members of the linear radicals CnCH and CnN feasible?

    International Nuclear Information System (INIS)

    Pauzat, F.; Ellinger, Y.; Mclean, A.D.

    1991-01-01

    Rotational constants and dipole moments for linear-chain radicals CnCH and CnN are estimated using a combinatiaon of ab initio molecular orbital calculations and observed data on the starting members of the series. CnCH with n = 0-5 have been observed by radioastronomy in carbon-rich interstellar clouds; higher members of the series have 2Pi ground states with large dipole moments and are strong candidates for observation. CN and C3N have also been observed by radioastronomy; higher members of the series, with the possible exception of C5N, have 2Pi ground states with near-zero dipole moments making their interstellar detection hopeless under present observational conditions. C5N can be a strong candidate only if it has a 2Sigma ground state, and best computations so far indicate that this is not the case. 20 refs

  18. Limited magnetic resonance imaging of the lumbar spine has high sensitivity for detection of acute fractures, infection, and malignancy

    International Nuclear Information System (INIS)

    Wang, Benjamin; Fintelmann, Florian J.; Kamath, Ravi S.; Kattapuram, Susan V.; Rosenthal, Daniel I.

    2016-01-01

    The objective of this study is to determine how a limited protocol MR examination compares to a full conventional MR examination for the detection of non-degenerative pathology such as acute fracture, infection, and malignancy. A sample of 349 non-contrast MR exams was selected retrospectively containing a 3:1:1:1 distribution of negative/degenerative change only, acute fracture, infection, and malignancy. This resulted in an even distribution of pathology and non-pathology. A limited protocol MR exam was simulated by extracting T1-weighted sagittal and T2-weighted fat-saturated (or STIR) sagittal sequences from each exam and submitting them for blinded review by two experienced musculoskeletal radiologists. The exams were evaluated for the presence or absence of non-degenerative pathology. Interpretation of the limited exam was compared to the original report of the full examination. If either reader disagreed with the original report, the case was submitted for an unblinded adjudication process with the participation of a third musculoskeletal radiologist to establish a consensus diagnosis. There were five false negatives for a sensitivity of 96.9 % for the limited protocol MR exam. Infection in the psoas, paraspinal muscles, and sacroiliac joint, as well as acute fractures in transverse processes and sacrum were missed by one or more readers. No cases of malignancy were missed. Overall diagnostic accuracy was 96.0 % (335/349). MR imaging of the lumbar spine limited to sagittal T1-weighted and sagittal T2 fat-saturated (or STIR) sequences has high sensitivity for the detection of acute fracture, infection, or malignancy compared to a conventional MR examination. (orig.)

  19. Limited magnetic resonance imaging of the lumbar spine has high sensitivity for detection of acute fractures, infection, and malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Benjamin; Fintelmann, Florian J.; Kamath, Ravi S.; Kattapuram, Susan V.; Rosenthal, Daniel I. [Massachusetts General Hospital, Department of Radiology, Boston, MA (United States)

    2016-12-15

    The objective of this study is to determine how a limited protocol MR examination compares to a full conventional MR examination for the detection of non-degenerative pathology such as acute fracture, infection, and malignancy. A sample of 349 non-contrast MR exams was selected retrospectively containing a 3:1:1:1 distribution of negative/degenerative change only, acute fracture, infection, and malignancy. This resulted in an even distribution of pathology and non-pathology. A limited protocol MR exam was simulated by extracting T1-weighted sagittal and T2-weighted fat-saturated (or STIR) sagittal sequences from each exam and submitting them for blinded review by two experienced musculoskeletal radiologists. The exams were evaluated for the presence or absence of non-degenerative pathology. Interpretation of the limited exam was compared to the original report of the full examination. If either reader disagreed with the original report, the case was submitted for an unblinded adjudication process with the participation of a third musculoskeletal radiologist to establish a consensus diagnosis. There were five false negatives for a sensitivity of 96.9 % for the limited protocol MR exam. Infection in the psoas, paraspinal muscles, and sacroiliac joint, as well as acute fractures in transverse processes and sacrum were missed by one or more readers. No cases of malignancy were missed. Overall diagnostic accuracy was 96.0 % (335/349). MR imaging of the lumbar spine limited to sagittal T1-weighted and sagittal T2 fat-saturated (or STIR) sequences has high sensitivity for the detection of acute fracture, infection, or malignancy compared to a conventional MR examination. (orig.)

  20. Colorimetric detection of cholesterol based on enzyme modified gold nanoparticles

    Science.gov (United States)

    Nirala, Narsingh R.; Saxena, Preeti S.; Srivastava, Anchal

    2018-02-01

    We develop a simple colorimetric method for determination of free cholesterol in aqueous solution based on functionalized gold nanoparticles with cholesterol oxidase. Functionalized gold nanoparticles interact with free cholesterol to produce H2O2 in proportion to the level of cholesterol visually is being detected. The quenching in optical properties and agglomeration of functionalized gold nanoparticles play a key role in cholesterol sensing due to the electron accepting property of H2O2. While the lower ranges of cholesterol (lower detection limit i.e. 0.2 mg/dL) can be effectively detected using fluorescence study, the absorption study attests evident visual color change which becomes effective for detection of higher ranges of cholesterol (lower detection limit i.e. 19 mg/dL). The shades of red gradually change to blue/purple as the level of cholesterol detected (as evident at 100 mg/dL) using unaided eye without the use of expensive instruments. The potential of the proposed method to be applied in the field is shown by the proposed cholesterol measuring color wheel.

  1. Heat-flow and temperature control in Tian–Calvet microcalorimeters: toward higher detection limits

    International Nuclear Information System (INIS)

    Vilchiz-Bravo, L E; Pacheco-Vega, A; Handy, B E

    2010-01-01

    Strategies based on the principle of heat flow and temperature control were implemented, and experimentally tested, to increase the sensitivity of a Tian–Calvet microcalorimeter for measuring heats of adsorption. Here, both heat-flow and temperature control schemes were explored to diminish heater-induced thermal variations within the heat sink element, hence obtaining less noise in the baseline signal. PID controllers were implemented within a closed-loop system to perform the control actions in a calorimetric setup. The experimental results demonstrate that the heat flow control strategy provided a better baseline stability when compared to the temperature control. The effects on the results stemming from the type of power supply used were also investigated

  2. Potential and limits of Raman spectroscopy for carotenoid detection in microorganisms: implications for astrobiology

    Science.gov (United States)

    Jehlička, Jan; Edwards, Howell G. M.; Osterrothová, Kateřina; Novotná, Julie; Nedbalová, Linda; Kopecký, Jiří; Němec, Ivan; Oren, Aharon

    2014-01-01

    In this paper, it is demonstrated how Raman spectroscopy can be used to detect different carotenoids as possible biomarkers in various groups of microorganisms. The question which arose from previous studies concerns the level of unambiguity of discriminating carotenoids using common Raman microspectrometers. A series of laboratory-grown microorganisms of different taxonomic affiliation was investigated, such as halophilic heterotrophic bacteria, cyanobacteria, the anoxygenic phototrophs, the non-halophilic heterotrophs as well as eukaryotes (Ochrophyta, Rhodophyta and Chlorophyta). The data presented show that Raman spectroscopy is a suitable tool to assess the presence of carotenoids of these organisms in cultures. Comparison is made with the high-performance liquid chromatography approach of analysing pigments in extracts. Direct measurements on cultures provide fast and reliable identification of the pigments. Some of the carotenoids studied are proposed as tracers for halophiles, in contrast with others which can be considered as biomarkers of other genera. The limits of application of Raman spectroscopy are discussed for a few cases where the current Raman spectroscopic approach does not allow discriminating structurally very similar carotenoids. The database reported can be used for applications in geobiology and exobiology for the detection of pigment signals in natural settings. PMID:25368348

  3. Composite Estimation for Single-Index Models with Responses Subject to Detection Limits

    KAUST Repository

    Tang, Yanlin; Wang, Huixia Judy; Liang, Hua

    2017-01-01

    We propose a semiparametric estimator for single-index models with censored responses due to detection limits. In the presence of left censoring, the mean function cannot be identified without any parametric distributional assumptions, but the quantile function is still identifiable at upper quantile levels. To avoid parametric distributional assumption, we propose to fit censored quantile regression and combine information across quantile levels to estimate the unknown smooth link function and the index parameter. Under some regularity conditions, we show that the estimated link function achieves the non-parametric optimal convergence rate, and the estimated index parameter is asymptotically normal. The simulation study shows that the proposed estimator is competitive with the omniscient least squares estimator based on the latent uncensored responses for data with normal errors but much more efficient for heavy-tailed data under light and moderate censoring. The practical value of the proposed method is demonstrated through the analysis of a human immunodeficiency virus antibody data set.

  4. Composite Estimation for Single-Index Models with Responses Subject to Detection Limits

    KAUST Repository

    Tang, Yanlin

    2017-11-03

    We propose a semiparametric estimator for single-index models with censored responses due to detection limits. In the presence of left censoring, the mean function cannot be identified without any parametric distributional assumptions, but the quantile function is still identifiable at upper quantile levels. To avoid parametric distributional assumption, we propose to fit censored quantile regression and combine information across quantile levels to estimate the unknown smooth link function and the index parameter. Under some regularity conditions, we show that the estimated link function achieves the non-parametric optimal convergence rate, and the estimated index parameter is asymptotically normal. The simulation study shows that the proposed estimator is competitive with the omniscient least squares estimator based on the latent uncensored responses for data with normal errors but much more efficient for heavy-tailed data under light and moderate censoring. The practical value of the proposed method is demonstrated through the analysis of a human immunodeficiency virus antibody data set.

  5. Detection limits for radioanalytical counting techniques

    International Nuclear Information System (INIS)

    Hartwell, J.K.

    1975-06-01

    In low-level radioanalysis it is usually necessary to test the sample net counts against some ''Critical Level'' in order to determine if a given result indicates detection. This is an interpretive review of the work by Nicholson (1963), Currie (1968) and Gilbert (1974). Nicholson's evaluation of three different computational formulas for estimation of the ''Critical Level'' is discussed. The details of Nicholson's evaluation are presented along with a basic discussion of the testing procedures used. Recommendations are presented for calculation of confidence intervals, for reporting of analytical results, and for extension of the derived formula to more complex cases such as multiple background counts, multiple use of a single background count, and gamma spectrometric analysis

  6. Assessment of detection limits of fiber-optic distributed temperature sensing for detection of illicit connections

    NARCIS (Netherlands)

    Nienhuis, J.; De Haan, C.; Langeveld, J.G.; Klootwijk, M.; Clemens, F.H.L.R.

    2012-01-01

    Distributed Temperature Sensing (DTS) with fiber-optic cables is a powerful tool to detect illicit connections in storm sewer systems. High frequency temperature measurements along the in-sewer cable create a detailed representation of temperature anomalies due to illicit discharges. The detection

  7. Systematic optimization of multiplex zymography protocol to detect active cathepsins K, L, S, and V in healthy and diseased tissue: compromise among limits of detection, reduced time, and resources.

    Science.gov (United States)

    Dumas, Jerald E; Platt, Manu O

    2013-07-01

    Cysteine cathepsins are a family of proteases identified in cancer, atherosclerosis, osteoporosis, arthritis, and a number of other diseases. As this number continues to rise, so does the need for low cost, broad use quantitative assays to detect their activity and can be translated to the clinic in the hospital or in low resource settings. Multiplex cathepsin zymography is one such assay that detects subnanomolar levels of active cathepsins K, L, S, and V in cell or tissue preparations observed as clear bands of proteolytic activity after gelatin substrate SDS-PAGE with conditions optimal for cathepsin renaturing and activity. Densitometric analysis of the zymogram provides quantitative information from this low cost assay. After systematic modifications to optimize cathepsin zymography, we describe reduced electrophoresis time from 2 h to 10 min, incubation assay time from overnight to 4 h, and reduced minimal tissue protein necessary while maintaining sensitive detection limits; an evaluation of the pros and cons of each modification is also included. We further describe image acquisition by Smartphone camera, export to Matlab, and densitometric analysis code to quantify and report cathepsin activity, adding portability and replacing large scale, darkbox imaging equipment that could be cost prohibitive in limited resource settings.

  8. Systematic optimization of multiplex zymography protocol to detect active cathepsins K, L, S, and V in healthy and diseased tissue: compromise between limits of detection, reduced time, and resources

    Science.gov (United States)

    Dumas, Jerald E.; Platt, Manu O.

    2013-01-01

    Cysteine cathepsins are a family of proteases identified in cancer, atherosclerosis, osteoporosis, arthritis and a number of other diseases. As this number continues to rise, so does the need for low cost, broad use quantitative assays to detect their activity and can be translated to the clinic in the hospital or in low resource settings. Multiplex cathepsin zymography is one such assay that detects subnanomolar levels of active cathepsins K, L, S, and V in cell or tissue preparations observed as cleared bands of proteolytic activity after gelatin substrate SDS-PAGE with conditions optimal for cathepsin renaturing and activity. Densitometric analysis of the zymogram provides quantitative information from this low cost assay. After systematic modifications to optimize cathepsin zymography, we describe reduced electrophoresis time from 2 hours to 10 minutes, incubation assay time from overnight to 4 hours, and reduced minimal tissue protein necessary while maintaining sensitive detection limits; an evaluation of the pros and cons of each modification is also included. We further describe image acquisition by smartphone camera, export to Matlab, and densitometric analysis code to quantify and report cathepsin activity, adding portability and replacing large scale, darkbox imaging equipment that could be cost prohibitive in limited resource settings. PMID:23532386

  9. DNA isolation protocols affect the detection limit of PCR approaches of bacteria in samples from the human gastrointestinal tract

    NARCIS (Netherlands)

    Zoetendal, E.G.; Ben-Amor, K.; Akkermans, A.D.L.; Abee, T.; Vos, de W.M.

    2001-01-01

    A major concern in molecular ecological studies is the lysis efficiency of different bacteria in a complex ecosystem. We used a PCR-based 16S rDNA approach to determine the effect of two DNA isolation protocols (i.e. the bead beating and Triton-X100 method) on the detection limit of seven

  10. ON COMPUTING UPPER LIMITS TO SOURCE INTENSITIES

    International Nuclear Information System (INIS)

    Kashyap, Vinay L.; Siemiginowska, Aneta; Van Dyk, David A.; Xu Jin; Connors, Alanna; Freeman, Peter E.; Zezas, Andreas

    2010-01-01

    A common problem in astrophysics is determining how bright a source could be and still not be detected in an observation. Despite the simplicity with which the problem can be stated, the solution involves complicated statistical issues that require careful analysis. In contrast to the more familiar confidence bound, this concept has never been formally analyzed, leading to a great variety of often ad hoc solutions. Here we formulate and describe the problem in a self-consistent manner. Detection significance is usually defined by the acceptable proportion of false positives (background fluctuations that are claimed as detections, or Type I error), and we invoke the complementary concept of false negatives (real sources that go undetected, or Type II error), based on the statistical power of a test, to compute an upper limit to the detectable source intensity. To determine the minimum intensity that a source must have for it to be detected, we first define a detection threshold and then compute the probabilities of detecting sources of various intensities at the given threshold. The intensity that corresponds to the specified Type II error probability defines that minimum intensity and is identified as the upper limit. Thus, an upper limit is a characteristic of the detection procedure rather than the strength of any particular source. It should not be confused with confidence intervals or other estimates of source intensity. This is particularly important given the large number of catalogs that are being generated from increasingly sensitive surveys. We discuss, with examples, the differences between these upper limits and confidence bounds. Both measures are useful quantities that should be reported in order to extract the most science from catalogs, though they answer different statistical questions: an upper bound describes an inference range on the source intensity, while an upper limit calibrates the detection process. We provide a recipe for computing upper

  11. Computer-aided detection and automated CT volumetry of pulmonary nodules

    International Nuclear Information System (INIS)

    Marten, Katharina; Engelke, Christoph

    2007-01-01

    With use of multislice computed tomography (MSCT), small pulmonary nodules are being detected in vast numbers, constituting the majority of all noncalcified lung nodules. Although the prevalence of lung cancers among such lesions in lung cancer screening populations is low, their isolation may contribute to increased patient survival. Computer-aided diagnosis (CAD) has emerged as a diverse set of diagnostic tools to handle the large number of images in MSCT datasets and most importantly, includes automated detection and volumetry of pulmonary nodules. Current CAD systems can significantly enhance experienced radiologists' performance and outweigh human limitations in identifying small lesions and manually measuring their diameters, augment observer consistency in the interpretation of such examinations and may thus help to detect significantly higher rates of early malignomas and give more precise estimates on chemotherapy response than can radiologists alone. In this review, we give an overview of current CAD in lung nodule detection and volumetry and discuss their relative merits and limitations. (orig.)

  12. Bureaucracy and Its Limits: Accountability and Rationality in Higher Education

    Science.gov (United States)

    Murphy, Mark

    2009-01-01

    Alongside debates concerning managerialism, marketisation and performativity, the question of accountability in higher education has come to the fore in recent commentary. Discussion of the subject has tended to be divided into two distinct camps. On the one hand, there are strong calls for more accountability to the public purse--a desire to…

  13. Photoinduced triplet-state electron transfer of platinum porphyrin: a one-step direct method for sensing iodide with an unprecedented detection limit

    KAUST Repository

    Masih, Dilshad; Aly, Shawkat Mohammede; Alarousu, Erkki; Mohammed, Omar F.

    2015-01-01

    previously unattained detection limit of 1 × 10−12 M) and economical method for the determination of iodide. To fully understand the reaction mechanism responsible for the phosphorescence quenching process, we have employed cutting-edge time-resolved laser

  14. Development of sandwich-form biosensor to detect Mycobacterium tuberculosis complex in clinical sputum specimens.

    Science.gov (United States)

    Shojaei, Taha Roodbar; Mohd Salleh, Mohamad Amran; Tabatabaei, Meisam; Ekrami, Alireza; Motallebi, Roya; Rahmani-Cherati, Tavoos; Hajalilou, Abdollah; Jorfi, Raheleh

    2014-01-01

    Mycobacterium tuberculosis, the causing agent of tuberculosis, comes second only after HIV on the list of infectious agents slaughtering many worldwide. Due to the limitations behind the conventional detection methods, it is therefore critical to develop new sensitive sensing systems capable of quick detection of the infectious agent. In the present study, the surface modified cadmium-telluride quantum dots and gold nanoparticles conjunct with two specific oligonucleotides against early secretory antigenic target 6 were used to develop a sandwich-form fluorescence resonance energy transfer-based biosensor to detect M. tuberculosis complex and differentiate M. tuberculosis and M. bovis Bacille Calmette-Guerin simultaneously. The sensitivity and specificity of the newly developed biosensor were 94.2% and 86.6%, respectively, while the sensitivity and specificity of polymerase chain reaction and nested polymerase chain reaction were considerably lower, 74.2%, 73.3% and 82.8%, 80%, respectively. The detection limits of the sandwich-form fluorescence resonance energy transfer-based biosensor were far lower (10 fg) than those of the polymerase chain reaction and nested polymerase chain reaction (100 fg). Although the cost of the developed nanobiosensor was slightly higher than those of the polymerase chain reaction-based techniques, its unique advantages in terms of turnaround time, higher sensitivity and specificity, as well as a 10-fold lower detection limit would clearly recommend this test as a more appropriate and cost-effective tool for large scale operations. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  15. Detection of irradiated frozen foods

    International Nuclear Information System (INIS)

    Miyahara, Makoto; Toyota, Masatake; Saito, Yukio

    1999-01-01

    To detect irradiated foods, ESR method is most frequently used, but its application is limited to a very narrow range of foods. So, the authors have attempted to introduce ortho-tyrosine method in this area. In this study, the possibility that ortho-tyrosine may be generated during analysis was examined and the results were compared with those obtained by other detection methods. The production of ortho-tyrosine by γ-ray was demonstrated to be due to secondary effects of the irradiation. The lower limit of this method was thought to be in a range, 0.1 - 0.2 kGy in consideration of individual difference depending on the method of processing, measurement, etc. The specificity and sensitivity of ortho-tyrosine method were remarkably improved compared with other methods. Realization of automatic analysis resulted to exclude the analytical difficulties due to labeling. However, the sensitivity of ESR method was much higher than that of ortho-tyrosine method. The present results show that further improvement of ortho-tyrosine method is necessary for practical application. (M.N.)

  16. Sensitivities and detection limits of X-ray fluorescence analysis with a 10 mCi241Am source

    International Nuclear Information System (INIS)

    Wundt, K.; Janghorbani, M.; Starke, K.

    1976-01-01

    Seven trace elements ranging from chromium to barium were preconcentrated on Amberlite IR-120 cation exchange paper and determined in an energy dispersive X-ray fluorescence system using a 10 mCi 241 Am source. Sensitivities were experimentally determined and checked with theoretically calculated values. The detection limits are compared with elemental levels present in typical surface waters and those allowed in drinking water. Appropriate conclusions as to feasibility of such a system for environmental monitoring are drawn. (orig.) [de

  17. The Use and Abuse of Limits of Detection in Environmental Analytical Chemistry

    Directory of Open Access Journals (Sweden)

    Richard J. C. Brown

    2008-01-01

    Full Text Available The limit of detection (LoD serves as an important method performance measure that is useful for the comparison of measurement techniques and the assessment of likely signal to noise performance, especially in environmental analytical chemistry. However, the LoD is only truly related to the precision characteristics of the analytical instrument employed for the analysis and the content of analyte in the blank sample. This article discusses how other criteria, such as sampling volume, can serve to distort the quoted LoD artificially and make comparison between various analytical methods inequitable. In order to compare LoDs between methods properly, it is necessary to state clearly all of the input parameters relating to the measurements that have been used in the calculation of the LoD. Additionally, the article discusses that the use of LoDs in contexts other than the comparison of the attributes of analytical methods, in particular when reporting analytical results, may be confusing, less informative than quoting the actual result with an accompanying statement of uncertainty, and may act to bias descriptive statistics.

  18. Lower limits of spin detection efficiency for two-parameter two-qubit (TPTQ) states with non-ideal ferromagnetic detectors

    Science.gov (United States)

    Majd, Nayereh; Ghasemi, Zahra

    2016-10-01

    We have investigated a TPTQ state as an input state of a non-ideal ferromagnetic detectors. Minimal spin polarization required to demonstrate spin entanglement according to entanglement witness and CHSH inequality with respect to (w.r.t.) their two free parameters have been found, and we have numerically shown that the entanglement witness is less stringent than the direct tests of Bell's inequality in the form of CHSH in the entangled limits of its free parameters. In addition, the lower limits of spin detection efficiency fulfilling secure cryptographic key against eavesdropping have been derived. Finally, we have considered TPTQ state as an output of spin decoherence channel and the region of ballistic transmission time w.r.t. spin relaxation time and spin dephasing time has been found.

  19. Determination of limits for smallest detectable and largest subcritical leakage cracks in piping systems

    International Nuclear Information System (INIS)

    Bieselt, R.; Wolf, M.

    1995-01-01

    Nuclear power plant piping systems - those still in their original as-built condition as well as upgraded designs - are subject to safety analysis. In order to limit the consequences of postulated piping failures, the basic safety concept incorporating rupture preclusion criteria is applied to specific high-energy piping systems. Leak-before-break analyses are also conducted within the framework of this concept. These analyses serve to determine the potential consequences of jet and reaction forces due to maximum subcritical leakage cracks while also establishing the minimum crack sizes that would be reliably detectable by the leakage rates resulting from these cracks. The boundary conditions for these analyses are not clearly defined. Using various examples as a basis, this paper presents and discusses how the leak-before-break concept can be applied. (orig.)

  20. Quantum Limits of Space-to-Ground Optical Communications

    Science.gov (United States)

    Hemmati, H.; Dolinar, S.

    2012-01-01

    For a pure loss channel, the ultimate capacity can be achieved with classical coherent states (i.e., ideal laser light): (1) Capacity-achieving receiver (measurement) is yet to be determined. (2) Heterodyne detection approaches the ultimate capacity at high mean photon numbers. (3) Photon-counting approaches the ultimate capacity at low mean photon numbers. A number of current technology limits drive the achievable performance of free-space communication links. Approaching fundamental limits in the bandwidth-limited regime: (1) Heterodyne detection with high-order coherent-state modulation approaches ultimate limits. SOA improvements to laser phase noise, adaptive optics systems for atmospheric transmission would help. (2) High-order intensity modulation and photon-counting can approach heterodyne detection within approximately a factor of 2. This may have advantages over coherent detection in the presence of turbulence. Approaching fundamental limits in the photon-limited regime (1) Low-duty cycle binary coherent-state modulation (OOK, PPM) approaches ultimate limits. SOA improvements to laser extinction ratio, receiver dark noise, jitter, and blocking would help. (2) In some link geometries (near field links) number-state transmission could improve over coherent-state transmission

  1. Coincidence detection of single-photon responses in the inner retina at the sensitivity limit of vision.

    Science.gov (United States)

    Ala-Laurila, Petri; Rieke, Fred

    2014-12-15

    Vision in starlight relies on our ability to detect single absorbed photons. Indeed, the sensitivity of dark-adapted vision approaches limits set by the quantal nature of light. This sensitivity requires neural mechanisms that selectively transmit quantal responses and suppress noise. Such mechanisms face an inevitable tradeoff because signal and noise cannot be perfectly separated, and rejecting noise also means rejecting signal. We report measurements of single-photon responses in the output signals of the primate retina. We find that visual signals arising from a few absorbed photons are read out fundamentally differently by primate On and Off parasol ganglion cells, key retinal output neurons. Off parasol cells respond linearly to near-threshold flashes, retaining sensitivity to each absorbed photon but maintaining a high level of noise. On parasol cells respond nonlinearly due to thresholding of their excitatory synaptic inputs. This nonlinearity reduces neural noise but also limits information about single-photon absorptions. The long-standing idea that information about each photon absorption is available for behavior at the sensitivity limit of vision is not universally true across retinal outputs. More generally, our work shows how a neural circuit balances the competing needs for sensitivity and noise rejection. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Fault diagnosis and refrigerant leak detection in vapour compression refrigeration systems

    Energy Technology Data Exchange (ETDEWEB)

    Tassou, S.A.; Grace, I.N. [Brunel University, Uxbridge (United Kingdom). Department of Mechanical Engineering

    2005-08-01

    The environmental impact of refrigeration systems can be reduced by operation at higher efficiency and reduction of refrigerant leakage. Refrigerant loss contributes both directly and indirectly to global warming through inefficient system operation, increased power consumption and greenhouse gas emissions and higher maintenance costs. Existing sensor-based leak detection methods are limited by the inability to detect gradual leakage and the need for careful sensor location. There is a requirement for a real-time performance monitoring approach to leak detection and fault diagnosis which overcomes these disadvantages. This paper reports on the development of a fault diagnosis and refrigerant leak detection system based on artificial intelligence and real-time performance monitoring. The system has been used successfully to distinguish between faulty and fault free operation, steady-state and transient operation, leakage and over charge conditions. Work currently underway is aimed at testing additional fault conditions and establishing further rules to distinguish between these patterns. (author)

  3. Limits to the Fraction of High-energy Photon Emitting Gamma-Ray Bursts

    Science.gov (United States)

    Akerlof, Carl W.; Zheng, WeiKang

    2013-02-01

    After almost four years of operation, the two instruments on board the Fermi Gamma-ray Space Telescope have shown that the number of gamma-ray bursts (GRBs) with high-energy photon emission above 100 MeV cannot exceed roughly 9% of the total number of all such events, at least at the present detection limits. In a recent paper, we found that GRBs with photons detected in the Large Area Telescope have a surprisingly broad distribution with respect to the observed event photon number. Extrapolation of our empirical fit to numbers of photons below our previous detection limit suggests that the overall rate of such low flux events could be estimated by standard image co-adding techniques. In this case, we have taken advantage of the excellent angular resolution of the Swift mission to provide accurate reference points for 79 GRB events which have eluded any previous correlations with high-energy photons. We find a small but significant signal in the co-added field. Guided by the extrapolated power-law fit previously obtained for the number distribution of GRBs with higher fluxes, the data suggest that only a small fraction of GRBs are sources of high-energy photons.

  4. LIMITS TO THE FRACTION OF HIGH-ENERGY PHOTON EMITTING GAMMA-RAY BURSTS

    International Nuclear Information System (INIS)

    Akerlof, Carl W.; Zheng, WeiKang

    2013-01-01

    After almost four years of operation, the two instruments on board the Fermi Gamma-ray Space Telescope have shown that the number of gamma-ray bursts (GRBs) with high-energy photon emission above 100 MeV cannot exceed roughly 9% of the total number of all such events, at least at the present detection limits. In a recent paper, we found that GRBs with photons detected in the Large Area Telescope have a surprisingly broad distribution with respect to the observed event photon number. Extrapolation of our empirical fit to numbers of photons below our previous detection limit suggests that the overall rate of such low flux events could be estimated by standard image co-adding techniques. In this case, we have taken advantage of the excellent angular resolution of the Swift mission to provide accurate reference points for 79 GRB events which have eluded any previous correlations with high-energy photons. We find a small but significant signal in the co-added field. Guided by the extrapolated power-law fit previously obtained for the number distribution of GRBs with higher fluxes, the data suggest that only a small fraction of GRBs are sources of high-energy photons.

  5. Detecting position using ARKit II: generating position-time graphs in real-time and further information on limitations of ARKit

    Science.gov (United States)

    Dilek, Ufuk; Erol, Mustafa

    2018-05-01

    ARKit is a framework which allows developers to create augmented reality apps for the iPhone and iPad. In a previous study, we had shown that it could be used to detect position in educational physics experiments and emphasized that the ability to provide position data in real-time was one of the prominent features of this newly emerging technology. In this study, we demonstrate an example of how real-time data acquisition can be employed in educational settings, report some of the limitations of ARKit and how we have overcome these limitations. By means of ARKit or a similar framework, ordinary mobile devices can be adapted for use in microcomputer-based lab activities.

  6. Higher-order amplitude squeezing of photons propagating through a semiconductor

    International Nuclear Information System (INIS)

    Nguyen Ba An.

    1996-12-01

    Photon amplitude K th power squeezing is studied when the coherent photon propagates through a semiconductor containing the exciton. If the exciton is prepared initially in a coherent state, the photon may become amplitude K th power squeezed. It is shown that, in the short-time limit, the photon squeezing in the P direction does not appear at all while that in the X direction is possible for all the amplitude power K. In the latter case, the amount of squeezing is larger for higher power K. Dependences on all the system parameters as well as on the output light detection moment are investigated in detail. (author). 14 refs, 8 figs

  7. Environmental analysis of higher brominated diphenyl ethers and decabromodiphenyl ethane.

    Science.gov (United States)

    Kierkegaard, Amelie; Sellström, Ulla; McLachlan, Michael S

    2009-01-16

    Methods for environmental analysis of higher brominated diphenyl ethers (PBDEs), in particular decabromodiphenyl ether (BDE209), and the recently discovered environmental contaminant decabromodiphenyl ethane (deBDethane) are reviewed. The extensive literature on analysis of BDE209 has identified several critical issues, including contamination of the sample, degradation of the analyte during sample preparation and GC analysis, and the selection of appropriate detection methods and surrogate standards. The limited experience with the analysis of deBDethane suggests that there are many commonalities with BDE209. The experience garnered from the analysis of BDE209 over the last 15 years will greatly facilitate progress in the analysis of deBDethane.

  8. Comparison of approximate formulas for decision levels and detection limits for paired counting with the exact results

    International Nuclear Information System (INIS)

    Potter, W.E.

    2005-01-01

    The exact probability density function for paired counting can be expressed in terms of modified Bessel functions of integral order when the expected blank count is known. Exact decision levels and detection limits can be computed in a straightforward manner. For many applications perturbing half-integer corrections to Gaussian distributions yields satisfactory results for decision levels. When there is concern about the uncertainty for the expected value of the blank count, a way to bound the errors of both types using confidence intervals for the expected blank count is discussed. (author)

  9. An experimental study on damage detection of structures using a timber beam

    International Nuclear Information System (INIS)

    Choi, Fook Choon; Li, Jianchun; Samali, Bijan; Crews, Keith

    2007-01-01

    Using vibration methods for the damage detection and structural health monitoring in bridge structures is rapidly developing. However, very little work has so far been reported on timber bridges. This paper intends to address such shortcomings by experimental investigation on a timber beam using a vibration based method to detect damage. A promising damage detection algorithm based on modal strain energy was adopted and modified to locate/evaluate damage. A laboratory investigation was conducted on a timber beam inflicted with various damage scenarios using modal tests. The modal parameters obtained from the undamaged and damaged state of the test beam were used in the computation of damage index, were then applied using a damage detection algorithm utilising modal strain energy and a statistical approach to detect location of damage. A mode shape reconstruction technique was used to enhance the capability of the damage detection algorithm with limited number of sensors. The test results and analysis show that location of damage can be accurately identified with limited sensors. The modified method is less dependent on the number of modes selected and can detect damage with a higher degree of confidence

  10. Current limiter circuit system

    Science.gov (United States)

    Witcher, Joseph Brandon; Bredemann, Michael V.

    2017-09-05

    An apparatus comprising a steady state sensing circuit, a switching circuit, and a detection circuit. The steady state sensing circuit is connected to a first, a second and a third node. The first node is connected to a first device, the second node is connected to a second device, and the steady state sensing circuit causes a scaled current to flow at the third node. The scaled current is proportional to a voltage difference between the first and second node. The switching circuit limits an amount of current that flows between the first and second device. The detection circuit is connected to the third node and the switching circuit. The detection circuit monitors the scaled current at the third node and controls the switching circuit to limit the amount of the current that flows between the first and second device when the scaled current is greater than a desired level.

  11. Memory and innovation in the spaces of higher education. The contribution of the architectural limit

    Directory of Open Access Journals (Sweden)

    Pablo Campos Calvo-Sotelo

    2016-03-01

    Full Text Available The current panorama of Higher Education recommends to carry out a review of the space/time places where teaching/learning processes are hosted. The spatial consequences derived from the innovation in teaching demand the incorporation of new academic places, alternative to the traditional typology of the classroom, in order to optimize the integral formation of the student —the ultimate mission of Universities—. The historical and obsolete architectural design of the classroom, as a rigid space/time container, must start a process of de-materialization, in such a way that it fosters more versatile learning methods, that can be activated in any time and place. To accomplish such a goal, more creative ambits must be generated, adapted to a modern understanding of the idea of learning, which must abandon its old-fashion passive and static format, in order to be transformed into a dynamic modality, closed to the student and committed to him. Innovation regarding the architectural configuration is directly connected tothe nature and transformation of the architectural limits which embrace and give shape to those places where formation occurs. The current demand of diversification and flexibility in learning areas must be satisfied by means of a correct articulation between the internal space of the classroom and its direct surrounding context, together with its social and cultural environment. Spatial and visual continuity generate new atmospheres that increase the quality of the teaching/learning processes. The new course of Higher Education needs a proactive review of the space/time dimensions of the traditional classroom, associated to the paradigm shift affecting modalities of teaching/learning, with the aim of generating new opportunities of innovation in Universities.

  12. Annoyance, detection and recognition of wind turbine noise.

    Science.gov (United States)

    Van Renterghem, Timothy; Bockstael, Annelies; De Weirt, Valentine; Botteldooren, Dick

    2013-07-01

    Annoyance, recognition and detection of noise from a single wind turbine were studied by means of a two-stage listening experiment with 50 participants with normal hearing abilities. In-situ recordings made at close distance from a 1.8-MW wind turbine operating at 22 rpm were mixed with road traffic noise, and processed to simulate indoor sound pressure levels at LAeq 40 dBA. In a first part, where people were unaware of the true purpose of the experiment, samples were played during a quiet leisure activity. Under these conditions, pure wind turbine noise gave very similar annoyance ratings as unmixed highway noise at the same equivalent level, while annoyance by local road traffic noise was significantly higher. In a second experiment, listeners were asked to identify the sample containing wind turbine noise in a paired comparison test. The detection limit of wind turbine noise in presence of highway noise was estimated to be as low as a signal-to-noise ratio of -23 dBA. When mixed with local road traffic, such a detection limit could not be determined. These findings support that noticing the sound could be an important aspect of wind turbine noise annoyance at the low equivalent levels typically observed indoors in practice. Participants that easily recognized wind-turbine(-like) sounds could detect wind turbine noise better when submersed in road traffic noise. Recognition of wind turbine sounds is also linked to higher annoyance. Awareness of the source is therefore a relevant aspect of wind turbine noise perception which is consistent with previous research. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Physics of detecting torsion and placing limits on its effects

    International Nuclear Information System (INIS)

    Stoeger, W.R.

    1985-01-01

    The essential principles of torsion-detection physics are presented, and an evaluation is conducted of several conceivable types of experiments and observations for actually detecting torsion fields, reemphasizing also the evident impossibility of successfully searching for its manifestations among cosmological relics. In particular, a polarized body, with net intrinsic (fundamental-particle) spin, is essential for detecting a torsion field. One which possesses only orbital angular momentum - rotation - or an unpolarized intrinsic spin density will not feel torsion. The fundamental problem in searching for such fields is the extremely small basic unit of the coupling or interaction energy between the torsion field and spin. The best way of maximizing the total interaction energy is to increase the spin density of the source sigma-s and at the same time the spin number SD of the detector. 15 references

  14. Detection Limit of Smectite by Chemin IV Laboratory Instrument: Preliminary Implications for Chemin on the Mars Science Laboratory Mission

    Science.gov (United States)

    Archilles, Cherie; Ming, D. W.; Morris, R. V.; Blake, D. F.

    2011-01-01

    The CheMin instrument on the Mars Science Laboratory (MSL) is an miniature X-ray diffraction (XRD) and X-ray fluorescence (XRF) instrument capable of detecting the mineralogical and elemental compositions of rocks, outcrops and soils on the surface of Mars. CheMin uses a microfocus-source Co X-ray tube, a transmission sample cell, and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D XRD patterns and energy-dispersive X-ray histograms from powdered samples. CRISM and OMEGA have identified the presence of phyllosilicates at several locations on Mars including the four candidate MSL landing sites. The objective of this study was to conduct preliminary studies to determine the CheMin detection limit of smectite in a smectite/olivine mixed mineral system.

  15. The use of a European coinage alloy to compare the detection limits of mobile XRF systems. A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Cesareo, R. [Struttura Dipartimentale di Matematica e Fisica, Universita di Sassari, Sassari (Italy); Ferretti, M. [CNR-Istituto per le Tecnologie Applicate ai Beni Culturali, Rome (Italy); Gigante, G.E. [Dipartimento di Fisica, Universita di Roma ' La Sapienza' , Rome (Italy); Guida, G. [Laboratorio di Chimica, Istituto Centrale per il Restauro, Rome (Italy); Moioli, P. [Unita Tecnico-Scientifica Materiali e Nuove Tecnologie, ENEA, Rome (Italy); Ridolfi, S. [Ars Mensurae, Rome (Italy); Roldan Garcia, C. [Unidad de Arqueometria, Instituto de Ciencia de Materiales, Universidad de Valencia, Valencia (Spain)

    2007-05-15

    The investigation of archaeological and historical materials makes use of techniques that, though borrowed from other fields of research and industrial production, frequently have to be 're-invented' because of peculiar characteristics of the analysed objects. Artistic relevance, limited movability, compositional and structural heterogeneity radically change the experimental approach and often require ad hoc designed equipment. These considerations also apply to x-ray fluorescence, especially regarding mobile systems. The extensive development and use of mobile spectrometers has produced an extremely diversified context and created the need for common criteria to evaluate their performances as well as the advisability of a survey on the existing equipment. This paper shows the feasibility of such an idea through a demonstrative survey that was carried out among users of different mobile x-ray fluorescence spectrometry (XRF) systems in the areas of Rome, Italy and Valencia, Spain. The experimental protocol was based on measuring spectrometer detection limits with the single standard method. The standard was the 50 Euro-cent coin, whose alloy is made of 89% Cu, 5% Al, 5% Zn, 1% Sn; the large spread of the European currency guarantees maximum availability. The experimental data show that the use of different x-ray tubes and detectors results in detection limits that may differ from each other by a factor of 6 for Zn and almost 100 for Sn; despite the large number of variables that in principle affect the performance, it was observed that the high voltage of the x-ray tube is the most important parameter. (authors)

  16. A quantitative method for determining a representative detection limit of the forensic luminol test for latent bloodstains.

    Science.gov (United States)

    Cassidy, Brianna M; Lu, Zhenyu; Martin, Jennifer P; Tazik, Shawna K; Kellogg, Katie W; DeJong, Stephanie A; Belliveau, Elle O; Kilgore, Katherine E; Ervin, Samantha M; Meece-Rayle, Mackenzie; Abraham, Alyssa M; Myrick, Michael L; Morgan, Stephen L

    2017-09-01

    The luminol test has been used for over 60 years by forensic investigators for presumptive identification of blood and visualization of blood splatter patterns. Multiple studies have estimated the limit of detection (LD) for bloodstains when luminol is employed, with results ranging from 100× to 5,000,000× dilute. However, these studies typically have not identified and controlled important experimental variables which may affect the luminol LD for bloodstains. Without control of experimental parameters in the laboratory, variables which affect the potential of presumptive bloodstain test methods remain largely unknown, and comparisons required to establish new, more powerful detection methods are simply impossible. We have developed a quantitative method to determine the relationship between the amount of blood present and its reaction with luminol by measuring, under controlled conditions, the resulting chemiluminescent intensity with a video camera, combined with processing of the digital intensity data. The method resulted in an estimated LD for bloodstains on cotton fabric at ∼200,000× diluted blood with a specific luminol formulation. Although luminol is the focus of this study, the experimental protocol used could be modified to study effects of variables using other blood detection reagents. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Mlifdect: Android Malware Detection Based on Parallel Machine Learning and Information Fusion

    Directory of Open Access Journals (Sweden)

    Xin Wang

    2017-01-01

    Full Text Available In recent years, Android malware has continued to grow at an alarming rate. More recent malicious apps’ employing highly sophisticated detection avoidance techniques makes the traditional machine learning based malware detection methods far less effective. More specifically, they cannot cope with various types of Android malware and have limitation in detection by utilizing a single classification algorithm. To address this limitation, we propose a novel approach in this paper that leverages parallel machine learning and information fusion techniques for better Android malware detection, which is named Mlifdect. To implement this approach, we first extract eight types of features from static analysis on Android apps and build two kinds of feature sets after feature selection. Then, a parallel machine learning detection model is developed for speeding up the process of classification. Finally, we investigate the probability analysis based and Dempster-Shafer theory based information fusion approaches which can effectively obtain the detection results. To validate our method, other state-of-the-art detection works are selected for comparison with real-world Android apps. The experimental results demonstrate that Mlifdect is capable of achieving higher detection accuracy as well as a remarkable run-time efficiency compared to the existing malware detection solutions.

  18. The detection and stabilisation of limit cycle for deterministic finite automata

    Science.gov (United States)

    Han, Xiaoguang; Chen, Zengqiang; Liu, Zhongxin; Zhang, Qing

    2018-04-01

    In this paper, the topological structure properties of deterministic finite automata (DFA), under the framework of the semi-tensor product of matrices, are investigated. First, the dynamics of DFA are converted into a new algebraic form as a discrete-time linear system by means of Boolean algebra. Using this algebraic description, the approach of calculating the limit cycles of different lengths is given. Second, we present two fundamental concepts, namely, domain of attraction of limit cycle and prereachability set. Based on the prereachability set, an explicit solution of calculating domain of attraction of a limit cycle is completely characterised. Third, we define the globally attractive limit cycle, and then the necessary and sufficient condition for verifying whether all state trajectories of a DFA enter a given limit cycle in a finite number of transitions is given. Fourth, the problem of whether a DFA can be stabilised to a limit cycle by the state feedback controller is discussed. Criteria for limit cycle-stabilisation are established. All state feedback controllers which implement the minimal length trajectories from each state to the limit cycle are obtained by using the proposed algorithm. Finally, an illustrative example is presented to show the theoretical results.

  19. Shot-Noise Limited Time-Encoded Raman Spectroscopy

    Directory of Open Access Journals (Sweden)

    Sebastian Karpf

    2017-01-01

    Full Text Available Raman scattering, an inelastic scattering mechanism, provides information about molecular excitation energies and can be used to identify chemical compounds. Albeit being a powerful analysis tool, especially for label-free biomedical imaging with molecular contrast, it suffers from inherently low signal levels. This practical limitation can be overcome by nonlinear enhancement techniques like stimulated Raman scattering (SRS. In SRS, an additional light source stimulates the Raman scattering process. This can lead to orders of magnitude increase in signal levels and hence faster acquisition in biomedical imaging. However, achieving a broad spectral coverage in SRS is technically challenging and the signal is no longer background-free, as either stimulated Raman gain (SRG or loss (SRL is measured, turning a sensitivity limit into a dynamic range limit. Thus, the signal has to be isolated from the laser background light, requiring elaborate methods for minimizing detection noise. Here, we analyze the detection sensitivity of a shot-noise limited broadband stimulated time-encoded Raman (TICO-Raman system in detail. In time-encoded Raman, a wavelength-swept Fourier domain mode locking (FDML laser covers a broad range of Raman transition energies while allowing a dual-balanced detection for lowering the detection noise to the fundamental shot-noise limit.

  20. Assessment of a New Lower-Cost Real-Time PCR Assay for Detection of High-Risk Human Papillomavirus: Useful for Cervical Screening in Limited-Resource Settings?

    Science.gov (United States)

    Fokom Domgue, Joel; Schiffman, Mark; Wentzensen, Nicolas H; Gage, Julia C; Castle, Philip E; Raine-Bennett, Tina R; Fetterman, Barbara; Lorey, Thomas; Poitras, Nancy E; Befano, Brian; Xie, Yi; Miachon, Lais S; Dean, Michael

    2017-08-01

    Inexpensive and easy-to-perform human papillomavirus (HPV) tests are needed for primary cervical cancer screening in lower-resource regions. In a convenience sample of 516 residual exfoliative cervical specimens from the Kaiser Permanente Northern California and U.S. National Cancer Institute Persistence and Progression Study, we assessed the agreement and clinical performance of a simple, inexpensive real-time PCR assay for the detection of 13 carcinogenic HPV types (the H13 assay; Hybribio, Hong Kong) that is marketed in limited-resource settings compared to previous testing by the Hybrid Capture 2 assay (HC2; Qiagen, Germantown, MD) and the Onclarity assay (BD Diagnostics, Sparks, MD). The test set was chosen to include many HPV-positive specimens. The reference standard was a combination of HC2 and Onclarity results for HPV detection and histologic diagnosis of controls (less than cervical intraepithelial neoplasia grade 2 [higher [CIN2+]) for disease status. In this enriched convenience sample, H13 tested positive for 94.4% of the 108 HC2- and Onclarity-positive CIN2+ specimens and negative for 88.2% of the 51 HC2- and Onclarity-negative limited-resource settings. Copyright © 2017 American Society for Microbiology.

  1. The Montreal Cognitive Assessment is superior to the Mini-Mental State Examination in detecting patients at higher risk of dementia.

    Science.gov (United States)

    Dong, YanHong; Lee, Wah Yean; Basri, Nur Adilah; Collinson, Simon Lowes; Merchant, Reshma A; Venketasubramanian, Narayanaswamy; Chen, Christopher Li-Hsian

    2012-11-01

    To examine the discriminant validity of the Montreal Cognitive Assessment (MoCA) and the Mini-Mental State Examination (MMSE) in detecting patients with cognitive impairment at higher risk for dementia at a memory clinic setting. Memory clinic patients were administered the MoCA, MMSE, and a comprehensive formal neuropsychological battery. Mild cognitive impairment (MCI) subtypes were dichotomized into two groups: single domain-MCI (sd-MCI) and multiple domain-MCI (md-MCI). Area under the receiver operating characteristic curve (ROC) analysis was used to compare the discriminatory ability of the MoCA and the MMSE. Two hundred thirty patients were recruited, of which 136 (59.1%) were diagnosed with dementia, 61 (26.5%) with MCI, and 33 (14.3%) with no cognitive impairment (NCI). The majority of MCI patients had md-MCI (n = 36, 59%). The MoCA had significantly larger AUCs than the MMSE in discriminating md-MCI from the lower risk group for incident dementia (NCI and sd-MCI) [MoCA 0.92 (95% CI, 0.86-0.98) vs. MMSE 0.84 (95% CI, 0.75-0.92), p = 0.02). At their optimal cut-off points, the MoCA (19/20) remained superior to the MMSE (23/24) in detecting md-MCI [sensitivity: 0.83 vs. 0.72; specificity: 0.86 vs. 0.83; PPV: 0.79 vs. 0.72; NPV: 0.89 vs. 0.83; correctly classified: 85.1% vs. 78.7%]. The MoCA is superior to the MMSE in the detection of patients with cognitive impairment at higher risk for incident dementia at a memory clinic setting.

  2. DETECTING ALIEN LIMIT CYCLES NEAR A HAMILTONIAN 2-SADDLE CYCLE

    OpenAIRE

    LUCA, Stijn; DUMORTIER, Freddy; Caubergh, M.; Roussarie, R.

    2009-01-01

    This paper aims at providing and example of a cubic Hamiltonian 2-saddle cycle that after bifurcation can give rise to an alien limit cycle; this is a limit cycle that is not controlled by a zero of the related Abelian integral. To guarantee the existence of an alien limit cycle one can verify generic conditions on the Abelian integral and on the transition map associated to the connections of the 2-saddle cycle. In this paper, a general method is developed to compute the first and second der...

  3. Does parallel item content on WOMAC's Pain and Function Subscales limit its ability to detect change in functional status?

    Directory of Open Access Journals (Sweden)

    Kennedy Deborah M

    2004-06-01

    Full Text Available Abstract Background Although the Western Ontario and McMaster University Osteoarthritis Index (WOMAC is considered the leading outcome measure for patients with osteoarthritis of the lower extremity, recent work has challenged its factorial validity and the physical function subscale's ability to detect valid change when pain and function display different profiles of change. This study examined the etiology of the WOMAC's physical function subscale's limited ability to detect change in the presence of discordant changes for pain and function. We hypothesized that the duplication of some items on the WOMAC's pain and function subscales contributed to this shortcoming. Methods Two eight-item physical function scales were abstracted from the WOMAC's 17-item physical function subscale: one contained activities and themes that were duplicated on the pain subscale (SIMILAR-8; the other version avoided overlapping activities (DISSIMILAR-8. Factorial validity of the shortened measures was assessed on 310 patients awaiting hip or knee arthroplasty. The shortened measures' abilities to detect change were examined on a sample of 104 patients following primary hip or knee arthroplasty. The WOMAC and three performance measures that included activity specific pain assessments – 40 m walk test, stair test, and timed-up-and-go test – were administered preoperatively, within 16 days of hip or knee arthroplasty, and at an interval of greater than 20 days following the first post-surgical assessment. Standardized response means were used to quantify change. Results The SIMILAR-8 did not demonstrate factorial validity; however, the factorial structure of the DISSIMILAR-8 was supported. The time to complete the performance measures more than doubled between the preoperative and first postoperative assessments supporting the theory that lower extremity functional status diminished over this interval. The DISSIMILAR-8 detected this deterioration in functional

  4. Limit of detection of a fiber optics gyroscope using a super luminescent radiation source; Limite de deteccion de un giroscopio de fibra optica usando una fuente de radiacion superluminiscente

    Energy Technology Data Exchange (ETDEWEB)

    Sandoval R, G.E. [Laboratorio de Optica Aplicada, Centro de Ciencias Aplicadas y Desarrollo Tecnologico, Universidad Nacional Autonoma de Mexico, Apartado Postal 70-186, 04510 Mexico D.F. (Mexico); Nikolaev, V.A. [Departamento de Optica y Radiofisica Cuantica, Universidad Estatal de Telecomunicaciones de San Petersburgo, M.A. Bonch-Bruyevich, Kanal Moika 61, Saint Petersburg 191186, (Russian Federation)

    2003-07-01

    The main objective of this work is to establish the dependence of characteristics of the fiber optics gyroscope (FOG) with respect to the parameters of the super luminescent emission source based on doped optical fiber with rare earth elements (Super luminescent Fiber Source, SFS), argument the pumping rate election of the SFS to obtain characteristics limits of the FOG sensibility. By using this type of emission source in the FOG is recommend to use the rate when the direction of the pumping signal coincide with the super luminescent signal. The most results are the proposition and argumentation of the SFS election as emission source to be use in the FOG of the phase type. Such a decision allow to increase the characteristics of the FOG sensibility in comparison with the use of luminescent source of semiconductors emission which are extensively used in the present time. The use of emission source of the SFS type allow to come closer to the threshold of the obtained sensibility limit (detection limit) which is determined with the shot noise. (Author)

  5. Limited irrigation research and infrared thermometry for detecting water stress

    Science.gov (United States)

    The USDA-ARS Limited Irrigation Research Farm, located outside of Greeley Colorado, is an experiment evaluating management perspectives of limited irrigation water. An overview of the farm systems is shown, including drip irrigation systems, water budgeting, and experimental design, as well as preli...

  6. The effect of laser ablation parameters on optical limiting properties of silver nanoparticles

    Science.gov (United States)

    Gursoy, Irmak; Yaglioglu, Halime Gul

    2017-09-01

    This paper presents the effect of laser ablation parameters on optical limiting properties of silver nanoparticles. The current applications of lasers such as range finding, guidance, detection, illumination and designation have increased the potential of damaging optical imaging systems or eyes temporary or permanently. The applications of lasers introduce risks for sensors or eyes, when laser power is higher than damage threshold of the detection system. There are some ways to protect these systems such as neutral density (nd) filters, shutters, etc. However, these limiters reduce the total amount of light that gets into the system. Also, response time of these limiters may not be fast enough to prevent damage and cause precipitation in performance due to deprivation of transmission or contrast. Therefore, optical limiting filters are needed that is transparent for low laser intensities and limit or block the high laser intensities. Metal nanoparticles are good candidates for such optical limiting filters for ns pulsed lasers or CW lasers due to their high damage thresholds. In this study we investigated the optical limiting performances of silver nanoparticles produced by laser ablation technique. A high purity silver target immersed in pure water was ablated with a Nd:YAG nanosecond laser at 532 nm. The effect of altering laser power and ablation time on laser ablation efficiency of nanoparticles was investigated experimentally and optimum values were specified. Open aperture Zscan experiment was used to investigate the effect of laser ablation parameters on the optical limiting performances of silver nanoparticles in pure water. It was found that longer ablation time decreases the optical limiting threshold. These results are useful for silver nanoparticles solutions to obtain high performance optical limiters.

  7. Temporal modulation transfer functions in cochlear implantees using a method that limits overall loudness cues

    Science.gov (United States)

    Fraser, Matthew; McKay, Colette M.

    2012-01-01

    Temporal modulation transfer functions (TMTFs) were measured for six users of cochlear implants, using different carrier rates and levels. Unlike most previous studies investigating modulation detection, the experimental design limited potential effects of overall loudness cues. Psychometric functions (percent correct discrimination of modulated from unmodulated stimuli versus modulation depth) were obtained. For each modulation depth, each modulated stimulus was loudness balanced to the unmodulated reference stimulus, and level jitter was applied in the discrimination task. The loudness-balance data showed that the modulated stimuli were louder than the unmodulated reference stimuli with the same average current, thus confirming the need to limit loudness cues when measuring modulation detection. TMTFs measured in this way had a low-pass characteristic, with a cut-off frequency (at comfortably loud levels) similar to that for normal-hearing listeners. A reduction in level caused degradation in modulation detection efficiency and a lower-cut-off frequency (i.e. poorer temporal resolution). An increase in carrier rate also led to a degradation in modulation detection efficiency, but only at lower levels or higher modulation frequencies. When detection thresholds were expressed as a proportion of dynamic range, there was no effect of carrier rate for the lowest modulation frequency (50 Hz) at either level. PMID:22146425

  8. Astrophysical limitations to the identification of dark matter: Indirect neutrino signals vis-a-vis direct detection recoil rates

    International Nuclear Information System (INIS)

    Serpico, Pasquale D.; Bertone, Gianfranco

    2010-01-01

    A convincing identification of dark matter (DM) particles can probably be achieved only through a combined analysis of different detections strategies, which provides an effective way of removing degeneracies in the parameter space of DM models. In practice, however, this program is made complicated by the fact that different strategies depend on different physical quantities, or on the same quantities but in a different way, making the treatment of systematic errors rather tricky. We discuss here the uncertainties on the recoil rate in direct-detection experiments and on the muon rate induced by neutrinos from dark matter annihilations in the Sun, and we show that, contrarily to the local DM density or overall cross section scale, irreducible astrophysical uncertainties affect the two rates in a different fashion, therefore limiting our ability to reconstruct the parameters of the dark matter particles. By varying within their respective errors astrophysical parameters such as the escape velocity and the velocity dispersion of dark matter particles, we show that the uncertainty on the relative strength of the neutrino and direct-detection signal is as large as a factor of 2 for typical values of the parameters, but can be even larger in some circumstances.

  9. Higher-Order Statistics for the Detection of Small Objects in a Noisy Background Application on Sonar Imaging

    Directory of Open Access Journals (Sweden)

    M. Amate

    2007-01-01

    Full Text Available An original algorithm for the detection of small objects in a noisy background is proposed. Its application to underwater objects detection by sonar imaging is addressed. This new method is based on the use of higher-order statistics (HOS that are locally estimated on the images. The proposed algorithm is divided into two steps. In a first step, HOS (skewness and kurtosis are estimated locally using a square sliding computation window. Small deterministic objects have different statistical properties from the background they are thus highlighted. The influence of the signal-to-noise ratio (SNR on the results is studied in the case of Gaussian noise. Mathematical expressions of the estimators and of the expected performances are derived and are experimentally confirmed. In a second step, the results are focused by a matched filter using a theoretical model. This enables the precise localization of the regions of interest. The proposed method generalizes to other statistical distributions and we derive the theoretical expressions of the HOS estimators in the case of a Weibull distribution (both when only noise is present or when a small deterministic object is present within the filtering window. This enables the application of the proposed technique to the processing of synthetic aperture sonar data containing underwater mines whose echoes have to be detected and located. Results on real data sets are presented and quantitatively evaluated using receiver operating characteristic (ROC curves.

  10. Reconstruction of the limit cycles by the delays method; Reconstruccion de ciclos limite por el metodo de los retardos

    Energy Technology Data Exchange (ETDEWEB)

    Castillo D, R.; Ortiz V, J. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Calleros M, G. [CFE, CNLV, Alto Lucero, Veracruz (Mexico)]. e-mail: rcd@nuclear.inin.mx

    2003-07-01

    The boiling water reactors (BWRs) are designed for usually to operate in a stable-lineal regime. In a limit cycle the behavior of the one system is no lineal-stable. In a BWR, instabilities of nuclear- thermohydraulics nature can take the reactor to a limit cycle. The limit cycles should to be avoided since the oscillations of power can cause thermal fatigue to the fuel and/or shroud. In this work the employment of the delays method is analyzed for its application in the detection of limit cycles in a nuclear power plant. The foundations of the method and it application to power signals to different operation conditions are presented. The analyzed signals are: to steady state, nuclear-thermohydraulic instability, a non linear transitory and, finally, failure of a controller plant . Among the main results it was found that the delays method can be applied to detect limit cycles in the power monitors of the BWR reactors. It was also found that the first zero of the autocorrelation function is an appropriate approach to select the delay in the detection of limit cycles, for the analyzed cases. (Author)

  11. Partial Least Squares Calibration Modeling Towards the Multivariate Limit of Detection for Enriched Isotopic Mixtures via Laser Ablation Molecular Isotopic Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Candace [Florida Agriculture & Mechanic Univ.; Profeta, Luisa [Alakai Defense Systems, Inc.; Akpovo, Codjo [Florida Agriculture & Mechanic Univ.; Stowe, Ashley [Y-12 National Security Complex, Oak Ridge, TN (United States); Johnson, Lewis [Florida Agriculture & Mechanic Univ.

    2017-10-09

    The psuedo univariate limit of detection was calculated to compare to the multivariate interval. ompared with results from the psuedounivariate LOD, the multivariate LOD includes other factors (i.e. signal uncertainties) and the reveals the significance in creating models that not only use the analyte’s emission line but also its entire molecular spectra.

  12. Detection limits of absorbed dose of ionizing radiation in molluscan shells as determined by e.p.r. spectroscopy

    International Nuclear Information System (INIS)

    Stachowicz, W.; Michalik, J.; Burlinska, G.; Sadlo, J.; Dziedzic-Goclawska, A.; Ostrowski, K.

    1995-01-01

    The exposure of waters to ionizing radiation from radionuclides imprisoned in dumped nuclear waste containers, freed in nuclear submarine accidents or released in underwater magma eruptions are difficult to be evaluated by conventional radiometric methods. Ionizing radiation evokes stable paramagnetic centers in crystalline lattice of mineral components in bone skeletons of mammals and fishes as well as in exoskeletons of mollusca. They give rise in e.p.r. to specific, extremely stable signals which are proposed to be applied as indicators of radiation exposure levels. In the present study the e.p.r. detection limits of the dose of ionizing radiation absorbed in shells of fresh water and marine mollusca (selected species) have been estimated. It has been found that with fresh water mollusca the dose of 1-2 Gy can be detected, while the sea water mollusca by one order of magnitude lower, i.e. about 0.1 Gy. (author)

  13. Chlorine-trapped CVD bilayer graphene for resistive pressure sensor with high detection limit and high sensitivity

    Science.gov (United States)

    Phuong Pham, Viet; Triet Nguyen, Minh; Park, Jin Woo; Kwak, Sung Soo; Nguyen, Dieu Hien Thi; Kyeom Mun, Mu; Danh Phan, Hoang; San Kim, Doo; Kim, Ki Hyun; Lee, Nae-Eung; Yeom, Geun Young

    2017-06-01

    Pressure sensing is one of the key functions for smart electronics. Considerably more effort is required to achieve the fabrication of pressure sensors that can imitate and overcome the sophisticated pressure sensing characteristics in nature and industry, especially in the innovation of materials and structures. Almost all of the pressure sensors reported until now have a high sensitivity at a low-pressure detection limit (type chlorine trap doping in the channel graphene with chlorine radicals without damaging the graphene. This work indicates that the ZGClG channel used for the pressure sensing device could also provide a simple and essential sensing platform for chemical-, medical-, and biological-sensing for future smart electronics.

  14. Detection of adulterated commercial Spanish beeswax.

    Science.gov (United States)

    Serra Bonvehi, J; Orantes Bermejo, F J

    2012-05-01

    The physical and chemical parameters (melting point and saponification number), and the fraction of hydrocarbons, monoesters, acids and alcohols have been determined in 90 samples of Spanish commercial beeswax from Apis mellifera L. The adulteration with paraffins of different melting point, cow tallow, stearic acid, and carnauba wax were determined by HTGC-FID/MS detection, and the research was focussed mainly on paraffins and microcrystallines waxes. In general, the added adulterant can be identified by the presence of non-naturally beeswax components, and by the differences of values of selected components between pure and adulterated beeswax. The detection limits were determined using pure and adulterated beeswax with different amounts of added waxes (5%, 10%, 20% and 30%). Percentages higher than 1-5% of each adulterant can be detected in the mixtures. Paraffin waxes were confirmed in 33 of the 90 samples analysed at concentrations between 5% and 30%. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Ultrahigh sensitivity made simple: nanoplasmonic label-free biosensing with an extremely low limit-of-detection for bacterial and cancer diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Chen, S; Svedendahl, M; Kaell, M; Gunnarsson, L; Dmitriev, A, E-mail: alexd@chalmers.s [Department of Applied Physics, Chalmers University of Technology, 41296 Goeteborg (Sweden)

    2009-10-28

    We present a simple and robust scheme for biosensing with an ultralow limit-of-detection down to several pg cm{sup -2} (or several tens of attomoles cm{sup -2}) based on optical label-free biodetection with localized surface plasmon resonances. The scheme utilizes cost-effective optical components and comprises a white light source, a properly functionalized sensor surface enclosed in a simple fluidics chip, and a spectral analyzer. The sensor surface is produced by a bottom-up nanofabrication technique with hole mask colloidal lithography. Despite its simplicity, the method is able to reliably detect protein-protein binding events at low picomolar and femtomolar concentrations, which is exemplified by the label-free detection of the extracellular adherence protein (EAP) found on the outer surface of the bacterium Staphylococcus aureus and of prostate-specific antigen (PSA), which is believed to be a prostate cancer marker. These experiments pave the way towards an ultra-sensitive yet compact biodetection platform for point-of-care diagnostics applications.

  16. Detection of 70 kDa heat shock protein in the saliva of dairy cows.

    Science.gov (United States)

    Lamy, Elsa; Jurkovich, Viktor; Rodrigues, Lénia; Geraldo, Ana; Cachucho, Liliana; Silva, Flávio; Matos, Catarina; Capela E Silva, Fernando; Pinheiro, Cristina; Könyves, László; Bakony, Mikolt; Pereira, Alfredo

    2017-08-01

    This Research Communication describes, for the first time, the detection of HSP70 in saliva of dairy cows. Thermal stress is a major environmental stress that limits animal growth, metabolism, and productivity. The cellular response to heat stress involves the synthesis of heat shock proteins (HSPs), presumably to protect the functional stability of cells at increasing temperatures. HSP70 has been found to be present in cattle blood serum and may also be present in other secretory fluids, such as saliva, as already observed in humans. The aim of this study was to detect heat shock protein HSP70 in bovine saliva. Saliva samples were taken from higher- (n = 5) and lower milk producing (n = 5) Holstein-Friesian cows in summer and in winter for the detection of HSP70. HSP70 concentrations were assayed using the ELISA technique. Salivary HSP70 concentrations ranged from 0·524 to 12·174 ng/ml in cows. Higher salivary HSP70 concentrations were significantly associated with higher milk production and higher environmental temperature, but not with rectal temperature.

  17. Limits on fast radio bursts at 145 MHz with ARTEMIS, a real-time software backend

    Science.gov (United States)

    Karastergiou, A.; Chennamangalam, J.; Armour, W.; Williams, C.; Mort, B.; Dulwich, F.; Salvini, S.; Magro, A.; Roberts, S.; Serylak, M.; Doo, A.; Bilous, A. V.; Breton, R. P.; Falcke, H.; Grießmeier, J.-M.; Hessels, J. W. T.; Keane, E. F.; Kondratiev, V. I.; Kramer, M.; van Leeuwen, J.; Noutsos, A.; Osłowski, S.; Sobey, C.; Stappers, B. W.; Weltevrede, P.

    2015-09-01

    Fast radio bursts (FRBs) are millisecond radio signals that exhibit dispersion larger than what the Galactic electron density can account for. We have conducted a 1446 h survey for FRBs at 145 MHz, covering a total of 4193 deg2 on the sky. We used the UK station of the low frequency array (LOFAR) radio telescope - the Rawlings Array - accompanied for a majority of the time by the LOFAR station at Nançay, observing the same fields at the same frequency. Our real-time search backend, Advanced Radio Transient Event Monitor and Identification System - ARTEMIS, utilizes graphics processing units to search for pulses with dispersion measures up to 320 cm-3 pc. Previous derived FRB rates from surveys around 1.4 GHz, and favoured FRB interpretations, motivated this survey, despite all previous detections occurring at higher dispersion measures. We detected no new FRBs above a signal-to-noise threshold of 10, leading to the most stringent upper limit yet on the FRB event rate at these frequencies: 29 sky-1 d-1 for five ms-duration pulses above 62 Jy. The non-detection could be due to scatter-broadening, limitations on the volume and time searched, or the shape of FRB flux density spectra. Assuming the latter and that FRBs are standard candles, the non-detection is compatible with the published FRB sky rate, if their spectra follow a power law with frequency (∝ να), with α ≳ +0.1, demonstrating a marked difference from pulsar spectra. Our results suggest that surveys at higher frequencies, including the low frequency component of the Square Kilometre Array, will have better chances to detect, estimate rates and understand the origin and properties of FRBs.

  18. The attendance of women in mammographic early detection programme and the results of the observation of the breast glands condition. 1. The attendance of higher schools female employees in mammography examination

    International Nuclear Information System (INIS)

    Romejko, M.; Kleszczewska, J.; Liszek, A.; Tarlowska, L.; Wronkowski, Z.

    1993-01-01

    The aim of the first part of this work is to assess the attendance in the early detection (mammography) in female employees of Warsaw-based higher schools aged 40-69. During the 4.5 year period (1985-1989) 1325 female employees of higher schools (23.5% of the schools' total employment) turned up to the Female Cancer Prevention Center of The Higher Schools' Medical Center (ZOZ) in Warsaw. Observation of this group continued until June 30, 1992. Majority of the women (56.5%) showed up only once, 21.7% came twice, and 21.8% at least three times. Out of the 1021 women (77% of all the examined female employees) who showed no symptoms in the first test, only 37% came again for the second checkup. Out of the 305 women who had changes detected in their X-ray images, 66% turned up for the second test. 23 women (1.7%) had suspicious mammography results or typical cancer symptoms in the first test. The present work shows that the reason of the insufficient attendance of higher schools' female employees in early detection programs need to be investigated and that a more efficient early detection system must be developed. (author)

  19. Sodium outleakage detection

    International Nuclear Information System (INIS)

    Casselman, C.

    1979-01-01

    Effective detection of outleakage from sodium facilities permits timely intervention capable of limiting the consequences of such leakage. Two types of detection systems are described: local and overall detection. The use of two independent systems in sodium facilities is recommended. (author)

  20. Opportunistic mammography screening provides effective detection rates in a limited resource healthcare system.

    Science.gov (United States)

    Teh, Yew-Ching; Tan, Gie-Hooi; Taib, Nur Aishah; Rahmat, Kartini; Westerhout, Caroline Judy; Fadzli, Farhana; See, Mee-Hoong; Jamaris, Suniza; Yip, Cheng-Har

    2015-05-15

    Breast cancer is the leading cause of cancer deaths in women world-wide. In low and middle income countries, where there are no population-based mammographic screening programmes, late presentation is common, and because of inadequate access to optimal treatment, survival rates are poor. Mammographic screening is well-studied in high-income countries in western populations, and because it has been shown to reduce breast cancer mortality, it has become part of the healthcare systems in such countries. However the performance of mammographic screening in a developing country is largely unknown. This study aims to evaluate the performance of mammographic screening in Malaysia, a middle income country, and to compare the stage and surgical treatment of screen-detected and symptomatic breast cancer. A retrospective review of 2510 mammograms performed from Jan to Dec 2010 in a tertiary medical centre is carried out. The three groups identified are the routine (opportunistic) screening group, the targeted (high risk) screening group and the diagnostic group. The performance indicators of each group is calculated, and stage at presentation and treatment between the screening and diagnostic group is analyzed. The cancer detection rate in the opportunistic screening group, targeted screening group, and the symptomatic group is 0.5 %, 1.25 % and 26 % respectively. The proportion of ductal carcinoma in situ is 23.1 % in the two screening groups compared to only 2.5 % in the diagnostic group. Among the opportunistic screening group, the cancer detection rate was 0.2 % in women below 50 years old compared to 0.65 % in women 50 years and above. The performance indicators are within international standards. Early-staged breast cancer (Stage 0-2) were 84.6 % in the screening groups compared to 61.1 % in the diagnostic group. From the results, in a setting with resource constraints, targeted screening of high risk individuals will give a higher yield, and if more resources are

  1. Investment Management in Higher Education Institutions

    Directory of Open Access Journals (Sweden)

    Jelena Stankevičienė

    2015-05-01

    Full Text Available Recently, the higher education sector faces a series of changes, such as increased competition, globalization, limited funding. Limited funding does not reveal the full potential of the higher education, too little funding restricts research performance, diminishes the quality of higher education, worsen the conditions for learning and this has important implications for sustainable value creation. The article explores relationship between education, sustainability and financial indicators in order to evaluate the situation and advancement in the European countries, applied multi-criteria evaluation method MULTIMOORA. This method aims to prove that the more encourage investment in higher education and research, the more sustainable the state is and creates sustainable value. The results revealed that the more financially stronger and stable country is, the better position by assessing both the scientific and the sustainability indicators. Financially stable country can give higher investment in education, to promote the conduct of research, create conditions for the formation of high-quality R&D, to prepare highly qualified specialists.

  2. Evaluation of uncertainty and detection limits in radioactivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Herranz, M. [Universidad del Pais Vasco/Euskal Herriko Unibertsitatea, Escuela Tecnica Superior de Ingenieria de Bilbao, Alda. Urquijo, s/n, 48013 Bilbao (Spain); Idoeta, R. [Universidad del Pais Vasco/Euskal Herriko Unibertsitatea, Escuela Tecnica Superior de Ingenieria de Bilbao, Alda. Urquijo, s/n, 48013 Bilbao (Spain)], E-mail: raquel.idoeta@ehu.es; Legarda, F. [Universidad del Pais Vasco/Euskal Herriko Unibertsitatea, Escuela Tecnica Superior de Ingenieria de Bilbao, Alda. Urquijo, s/n, 48013 Bilbao (Spain)

    2008-10-01

    The uncertainty associated with the assessment of the radioactive content of any sample depends on the net counting rate registered during the measuring process and on the different weighting factors needed to transform this counting rate into activity, activity per unit mass or activity concentration. This work analyses the standard uncertainties in these weighting factors as well as their contribution to the uncertainty in the activity reported for three typical determinations for environmental radioactivity measurements in the laboratory. It also studies the corresponding characteristic limits and their dependence on the standard uncertainty related to those weighting factors, offering an analysis of the effectiveness of the simplified characteristic limits as evaluated by various measuring software and laboratories.

  3. Evaluation of uncertainty and detection limits in radioactivity measurements

    International Nuclear Information System (INIS)

    Herranz, M.; Idoeta, R.; Legarda, F.

    2008-01-01

    The uncertainty associated with the assessment of the radioactive content of any sample depends on the net counting rate registered during the measuring process and on the different weighting factors needed to transform this counting rate into activity, activity per unit mass or activity concentration. This work analyses the standard uncertainties in these weighting factors as well as their contribution to the uncertainty in the activity reported for three typical determinations for environmental radioactivity measurements in the laboratory. It also studies the corresponding characteristic limits and their dependence on the standard uncertainty related to those weighting factors, offering an analysis of the effectiveness of the simplified characteristic limits as evaluated by various measuring software and laboratories

  4. A LIMIT ON THE NUMBER OF ISOLATED NEUTRON STARS DETECTED IN THE ROSAT ALL-SKY-SURVEY BRIGHT SOURCE CATALOG

    International Nuclear Information System (INIS)

    Turner, Monica L.; Rutledge, Robert E.; Letcavage, Ryan; Shevchuk, Andrew S. H.; Fox, Derek B.

    2010-01-01

    Using new and archival observations made with the Swift satellite and other facilities, we examine 147 X-ray sources selected from the ROSAT All-Sky-Survey Bright Source Catalog (RASS/BSC) to produce a new limit on the number of isolated neutron stars (INSs) in the RASS/BSC, the most constraining such limit to date. Independent of X-ray spectrum and variability, the number of INSs is ≤48 (90% confidence). Restricting attention to soft (kT eff < 200 eV), non-variable X-ray sources-as in a previous study-yields an all-sky limit of ≤31 INSs. In the course of our analysis, we identify five new high-quality INS candidates for targeted follow-up observations. A future all-sky X-ray survey with eROSITA, or another mission with similar capabilities, can be expected to increase the detected population of X-ray-discovered INSs from the 8-50 in the BSC, to (for a disk population) 240-1500, which will enable a more detailed study of neutron star population models.

  5. Limitations of Human Visual Working Memory

    OpenAIRE

    Wesenick, Maria-Barbara

    2004-01-01

    The present empirical study investigates limitations of human visual working memory (VWM). The experiments of the present work involve the experimental paradigm of change detection using simple geometrical objects in the form of rectangles of different colour, length, and orientation. It can be shown, that a limited performance in the temporary storage of visual information has multiple sources. Limitations of VWM can be attributed to a limited capacity or a limited duration, but also to limi...

  6. Detection of carcinoembryonic antigen using functional magnetic and fluorescent nanoparticles in magnetic separators

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, H. Y., E-mail: annetsai@csmu.edu.tw [Chung Shan Medical University, Department of Applied Chemistry (China); Chang, C. Y.; Li, Y. C.; Chu, W. C.; Viswanathan, K.; Bor Fuh, C., E-mail: cbfuh@ncnu.edu.tw [National Chi Nan University, Department of Applied Chemistry (China)

    2011-06-15

    We combined a sandwich immunoassay, anti-CEA/CEA/anti-CEA, with functional magnetic ({approx}80 nm) and fluorescent ({approx}180 nm) nanoparticles in magnetic separators to demonstrate a detection method for carcinoembryonic antigen (CEA). Determination of CEA in serum can be used in clinical diagnosis and monitoring of tumor-related diseases. The CEA concentrations in samples were deduced and determined based on the reference plot using the measured fluorescent intensity of sandwich nanoparticles from the sample. The linear range of CEA detection was from 18 ng/mL to 1.8 pg/mL. The detection limit of CEA was 1.8 pg/mL. In comparison with most other detection methods, this method had advantages of lower detection limit and wider linear range. The recovery was higher than 94%. The CEA concentrations of two serum samples were determined to be 9.0 and 55 ng/mL, which differed by 6.7% (9.6 ng/mL) and 9.1% (50 ng/mL) from the measurements of enzyme-linked immunosorbent assay (ELISA), respectively. The analysis time can be reduced to one third of ELISA. This method has good potential for other biomarker detections and biochemical applications.

  7. [A cell-based detection of ciguatoxin using sodium fluorescence probe].

    Science.gov (United States)

    Yuan, Jian-hui; Yang, Hui; Tang, Huan-wen; Huang, Wei; Xu, Xin-yun; Liu, Jian-jun; Ke, Yue-bin; Cheng, Jin-quan; Zhuang, Zhi-xiong

    2011-04-01

    To establish a cell-based detection method of ciguatoxin using fluorescence assay. Mouse neuroblastoma N-2A cells were exposed to ouabain and veratridine and different concentrations of standard ciguatoxin samples (P-CTX-1) to establish the curvilinear relationship between the toxin dosage and fluorescence intensity using the sodium fluorescence probe CoroNaTM Green. The toxicity curvilinear relationship was also generated between the toxin dosage and cell survival using CCK-8 method. Based on these standard curves, the presence of ciguatoxin was detected in 33 samples of deep-sea coral fish. A correlation was found between the detection results of cell-based fluorescence assay and cytotoxicity assay, whose detection limit reached 103 g/ml and 1012 g/ml, respectively. The cell-based fluorescent assay sensitivity showed a higher sensitivity than cytotoxicity assay with a 2-4 h reduction of the detection time. The cell-based fluorescent assay can quickly and sensitively detect ciguatoxin and may serve as a good option for preliminary screening of the toxin.

  8. Ultrasensitive norovirus detection using DNA aptasensor technology.

    Directory of Open Access Journals (Sweden)

    Amanda Giamberardino

    Full Text Available DNA aptamers were developed against murine norovirus (MNV using SELEX (Systematic Evolution of Ligands by EXponential enrichment. Nine rounds of SELEX led to the discovery of AG3, a promising aptamer with very high affinity for MNV as well as for lab-synthesized capsids of a common human norovirus (HuNoV outbreak strain (GII.3. Using fluorescence anisotropy, AG3 was found to bind with MNV with affinity in the low picomolar range. The aptamer could cross-react with HuNoV though it was selected against MNV. As compared to a non-specific DNA control sequence, the norovirus-binding affinity of AG3 was about a million-fold higher. In further tests, the aptamer also showed nearly a million-fold higher affinity for the noroviruses than for the feline calicivirus (FCV, a virus similar in size and structure to noroviruses. AG3 was incorporated into a simple electrochemical sensor using a gold nanoparticle-modified screen-printed carbon electrode (GNPs-SPCE. The aptasensor could detect MNV with a limit of detection of approximately 180 virus particles, for possible on-site applications. The lead aptamer candidate and the aptasensor platform show promise for the rapid detection and identification of noroviruses in environmental and clinical samples.

  9. Performance limitations at ISABELLE

    International Nuclear Information System (INIS)

    Keil, E.

    1975-01-01

    The transverse stability of coasting beams in the planned ISABELLE storage rings was studied. The beam--beam tune shift limitation at 0.005 can be avoided, and a computer simulation seems to show 0.005 is a pessimistic limit. For beams of reasonable smoothness on the edge, the actual limit should be somewhat higher. Some coupling effects due to the beam--beam interaction are also examined

  10. Exploiting Higher Order and Multi-modal Features for 3D Object Detection

    DEFF Research Database (Denmark)

    Kiforenko, Lilita

    that describe object visual appearance such as shape, colour, texture etc. This thesis focuses on robust object detection and pose estimation of rigid objects using 3D information. The thesis main contributions are novel feature descriptors together with object detection and pose estimation algorithms....... The initial work introduces a feature descriptor that uses edge categorisation in combination with a local multi-modal histogram descriptor in order to detect objects with little or no texture or surface variation. The comparison is performed with a state-of-the-art method, which is outperformed...... of the methods work well for one type of objects in a specific scenario, in another scenario or with different objects they might fail, therefore more robust solutions are required. The typical problem solution is the design of robust feature descriptors, where feature descriptors contain information...

  11. Estimation of the detection limit of an experimental model of tritium storage bed designed for 'in-situ' accountability

    International Nuclear Information System (INIS)

    Bulubasa, Gheorghe; Bidica, Nicolae; Stefanescu, Ioan; Bucur, Ciprian; Deaconu, Mariea

    2009-01-01

    During the water detritiation process most of the tritium inventory is transferred from water into the gaseous phase, then it is further enriched and finally extracted and safely stored. The control of tritium inventory is an acute issue from several points of view: - Financially - tritium is an expensive material; - Safeguard - tritium is considered as nuclear material of strategic importance; - Safety - tritium is a radioactive material: requirements for documented safety analysis report (to ensure strict limits on the total tritium allowed) and for evaluation of accident consequences associated with that inventory. Large amounts of tritium can be stored, in a very safely manner, as metal tritides. A bench-scale experiment of a tritium storage bed with integrated system for in-situ tritium inventory accountancy was designed and developed at ICSI Rm. Valcea. The calibration curve and the detection limit for this experimental model of tritium storage bed were determined. The experimental results are presented in this paper. (authors)

  12. Currie detection limits in gamma-ray spectroscopy

    International Nuclear Information System (INIS)

    Geer, L.-E. de

    2004-01-01

    Currie Hypothesis testing is applied to gamma-ray spectral data, where an optimum part of the peak is used and the background is considered well known from nearby channels. With this, the risk of making Type I errors is about 100 times lower than commonly assumed. A programme, PeakMaker, produces random peaks with given characteristics on the screen and calculations are done to facilitate a full use of Poisson statistics in spectrum analyses. Short technical note summary: The Currie decision limit concept applied to spectral data is reinterpreted, which gives better consistency between the selected error risk and the observed error rates. A PeakMaker program is described and the few count problem is analyzed

  13. Surface modification of alignment layer by ultraviolet irradiation to dramatically improve the detection limit of liquid-crystal-based immunoassay for the cancer biomarker CA125.

    Science.gov (United States)

    Su, Hui-Wen; Lee, Mon-Juan; Lee, Wei

    2015-05-01

    Liquid crystal (LC)-based biosensing has attracted much attention in recent years. We focus on improving the detection limit of LC-based immunoassay techniques by surface modification of the surfactant alignment layer consisting of dimethyloctadecyl[3-(trimethoxysilyl)propyl]ammonium chloride (DMOAP). The cancer biomarker CA125 was detected with an array of anti-CA125 antibodies immobilized on the ultraviolet (UV)-modified DMOAP monolayer. Compared with a pristine counterpart, UV irradiation enhanced the binding affinity of the CA125 antibody and reproducibility of immunodetection in which a detection limit of 0.01 ng∕ml for the cancer biomarker CA125 was achieved. Additionally, the optical texture observed under a crossed polarized microscope was correlated with the analyte concentration. In a proof-of-concept experiment using CA125-spiked human serum as the analyte, specific binding between the CA125 antigen and the anti-CA125 antibody resulted in a distinct and concentration-dependent optical response despite the high background caused by nonspecific binding of other biomolecules in the human serum. Results from this study indicate that UVmodification of the alignment layer, as well as detection with LCs of large birefringence, contributes to the enhanced performance of the label-free LC-based immunodetection, which may be considered a promising alternative to conventional label-based methods.

  14. Detection limits of nuclear radiation and radioactivity measurements. Digital, non-selective measurements on untreated specimens. Draft. Nachweisgrenzen bei Kernstrahlungs- und Radioaktivitaetsmessungen. Digitale, nichtselektive Messungen ohne Probenbehandlung. Entwurf

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    The standard applies to nuclear radiation measurements where the number of pulses is recorded directly, considering exclusively the statistical character of radioactive decay and pulse counting, with the measuring time being short with regard to the half-life of radionuclides, and instrument dead-times being neglectible. The standard is intended to define suitable characteristics allowing an evaluation of detection efficiency. Two criteria are explained for given error probabilities: the sensitivity limit which allows a decision to be made as to whether the pulses recorded include values contributed by the sample; the detection limit which permits an evaluation of the measuring method in terms of suitability to the measuring goals. (orig./HP).

  15. Improvement of detection limits in the annular 241Am radioisotope-excited X-ray fluorescence analysis for minor elements of environmental sample

    International Nuclear Information System (INIS)

    Thai My Phe; Ngo Quang Huy; Nguyen Van Suc; Tran Van Luyen; Nguyen Van Mai; Dao Van Hoang; Trinh Thi Bich

    2003-01-01

    The improvement of limit detection to elements Pb, Sr, Zr, Nd, and Ba in mud samples is presented. Two ways for reducing background radiation are: 1/ choosing the optimum γ-ray-excited X-ray assembly such as scattering angle (θ), filter for primary beam, excited holder, collimator for fluorescent lines, etc; 2/ using the chemical separation method to remove major composition for matrix reduction. (NHA)

  16. Detection of alpha-fetoprotein in magnetic immunoassay of thin channels using biofunctional nanoparticles

    Science.gov (United States)

    Tsai, H. Y.; Gao, B. Z.; Yang, S. F.; Li, C. S.; Fuh, C. Bor

    2014-01-01

    This paper presents the use of fluorescent biofunctional nanoparticles (10-30 nm) to detect alpha-fetoprotein (AFP) in a thin-channel magnetic immunoassay. We used an AFP model biomarker and s-shaped deposition zones to test the proposed detection method. The results show that the detection using fluorescent biofunctional nanoparticle has a higher throughput than that of functional microparticle used in previous experiments on affinity reactions. The proposed method takes about 3 min (versus 150 min of previous method) to detect 100 samples. The proposed method is useful for screening biomarkers in clinical applications, and can reduce the run time for sandwich immunoassays to less than 20 min. The detection limits (0.06 pg/ml) and linear ranges (0.068 pg/ml-0.68 ng/ml) of AFP using fluorescent biofunctional nanoparticles are the same as those of using functional microparticles within experimental errors. This detection limit is substantially lower and the linear range is considerably wider than those of enzyme-linked immunosorbent assay (ELISA) and other methods in sandwich immunoassay methods. The differences between this method and an ELISA in AFP measurements of serum samples were less than 12 %. The proposed method provides simple, fast, and sensitive detection with a high throughput for biomarkers.

  17. Breast scintigraphy today: indications and limitations

    International Nuclear Information System (INIS)

    Schillaci, Orazio; Buscombe, John R.

    2004-01-01

    Breast carcinoma is the most common neoplasm found among women in the Western world. Mammography (MM) is the most widely used diagnostic imaging method for screening and diagnosing breast cancer. However, despite technical improvements in recent years, MM has known diagnostic limits; consequently not all breast carcinomas are identified on mammograms, especially if the breast is dense, there is a breast prosthesis or the patient has previously undergone radiation, surgery or biopsy. In addition, the mammographic images of benign and malignant lesions can be similar. Therefore, abnormalities detected on MM frequently result in negative biopsies. Scintimammography (SM) is the functional imaging study of the breast using primarily the radiopharmaceuticals 99m Tc-sestamibi and 99m Tc-tetrofosmin. The main advantage of SM is that its functional basis makes this technique a useful complement to MM. SM resolves some of the main limitations of MM as it is not affected by changes in breast morphology. Several single-site and multi-centre studies have demonstrated that SM has an improved specificity compared with MM, because it is better able to distinguish malignant from benign breast lesions. Interestingly, except in smaller lesions, a higher sensitivity has been recorded for SM than for MM in most of these studies as well. Adjunctive use of SM when MM is equivocal can reduce the number of unnecessary breast biopsies and identify previously unexpected sites of breast cancer. SM appears unaffected by the anatomical changes seen following chemotherapy and radiotherapy, and so this technique can be particularly useful in monitoring the treatment of breast cancer patients, especially when breast-conserving treatment is given. The main limitation to SM has been the sub-optimal resolution of the standard Anger gamma camera, which makes it difficult to detect lesions of less than 10 mm; however, the development of high-resolution breast-dedicated gamma cameras may offer

  18. Breast scintigraphy today: indications and limitations

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio [Department of Biopathology and Diagnostic Imaging, University ' ' Tor Vergata' ' , Rome (Italy); Buscombe, John R. [Department of Nuclear Medicine, Royal Free Hospital, London (United Kingdom)

    2004-06-01

    Breast carcinoma is the most common neoplasm found among women in the Western world. Mammography (MM) is the most widely used diagnostic imaging method for screening and diagnosing breast cancer. However, despite technical improvements in recent years, MM has known diagnostic limits; consequently not all breast carcinomas are identified on mammograms, especially if the breast is dense, there is a breast prosthesis or the patient has previously undergone radiation, surgery or biopsy. In addition, the mammographic images of benign and malignant lesions can be similar. Therefore, abnormalities detected on MM frequently result in negative biopsies. Scintimammography (SM) is the functional imaging study of the breast using primarily the radiopharmaceuticals {sup 99m}Tc-sestamibi and {sup 99m}Tc-tetrofosmin. The main advantage of SM is that its functional basis makes this technique a useful complement to MM. SM resolves some of the main limitations of MM as it is not affected by changes in breast morphology. Several single-site and multi-centre studies have demonstrated that SM has an improved specificity compared with MM, because it is better able to distinguish malignant from benign breast lesions. Interestingly, except in smaller lesions, a higher sensitivity has been recorded for SM than for MM in most of these studies as well. Adjunctive use of SM when MM is equivocal can reduce the number of unnecessary breast biopsies and identify previously unexpected sites of breast cancer. SM appears unaffected by the anatomical changes seen following chemotherapy and radiotherapy, and so this technique can be particularly useful in monitoring the treatment of breast cancer patients, especially when breast-conserving treatment is given. The main limitation to SM has been the sub-optimal resolution of the standard Anger gamma camera, which makes it difficult to detect lesions of less than 10 mm; however, the development of high-resolution breast-dedicated gamma cameras may offer

  19. Work-related stress in midlife is associated with higher number of mobility limitation in older age-results from the FLAME study.

    Science.gov (United States)

    Kulmala, Jenni; Hinrichs, Timo; Törmäkangas, Timo; von Bonsdorff, Mikaela B; von Bonsdorff, Monika E; Nygård, Clas-Håkan; Klockars, Matti; Seitsamo, Jorma; Ilmarinen, Juhani; Rantanen, Taina

    2014-01-01

    The aim of this study is to investigate whether work-related stress symptoms in midlife are associated with a number of mobility limitations during three decades from midlife to late life. Data for the study come from the Finnish Longitudinal Study of Municipal Employees (FLAME). The study includes a total of 5429 public sector employees aged 44-58 years at baseline who had information available on work-related stress symptoms in 1981 and 1985 and mobility limitation score during the subsequent 28-year follow-up. Four midlife work-related stress profiles were identified: negative reactions to work and depressiveness, perceived decrease in cognition, sleep disturbances, and somatic symptoms. People with a high number of stress symptoms in 1981 and 1985 were categorized as having constant stress. The number of self-reported mobility limitations was computed based on an eight-item list of mobility tasks presented to the participants in 1992, 1997, and 2009. Data were analyzed using joint Poisson regression models. The study showed that depending on the stress profile, persons suffering from constant stress in midlife had a higher risk of 30-70 % for having one more mobility limitation during the following 28 years compared to persons without stress after adjusting for mortality, several lifestyle factors, and chronic conditions. A less pronounced risk increase (20-40 %) was observed for persons with occasional symptoms. The study suggests that effective interventions aiming to reduce work-related stress should focus on both primary and secondary prevention.

  20. The physics of detecting torsion and placing limits on its effects

    International Nuclear Information System (INIS)

    Stoeger, W.R.

    1985-01-01

    The essential principles of torsion-detection physics are presented and several conceivable types of experiments and observations for actually detecting torsion fields are evaluated reemphasizing also the evident impossibility of successfully searching for its manifestations among cosmological relics. In particular, a polarized body, with net intrinsic (fundamental-particle) spin, is essential for detecting a torsion field. One which possesses only orbital angular momentum-rotation-or an unpolarized intrinsic spin density will not feel torsion. The fundamental problem in searching for such fields is the extremely small basic unit of the coupling or interaction energy between the torsion field and spin, epsilonapprox.(8πG'/c 2 )(h 2 /4). The best way of maximizing the total interaction energy is to increase the spin density of the source σ 5 and, at the same time the ''spin number'' Ssub(D) of the detector. (author)

  1. 'Intelligent' triggering methodology for improved detectability of wavelength modulation diode laser absorption spectrometry applied to window-equipped graphite furnaces

    International Nuclear Information System (INIS)

    Gustafsson, Joergen; Axner, Ove

    2003-01-01

    The wavelength modulation-diode laser absorption spectrometry (WM-DLAS) technique experiences a limited detectability when window-equipped sample compartments are used because of multiple reflections between components in the optical system (so-called etalon effects). The problem is particularly severe when the technique is used with a window-equipped graphite furnace (GF) as atomizer since the heating of the furnace induces drifts of the thickness of the windows and thereby also of the background signals. This paper presents a new detection methodology for WM-DLAS applied to a window-equipped GF in which the influence of the background signals from the windows is significantly reduced. The new technique, which is based upon a finding that the WM-DLAS background signals from a window-equipped GF are reproducible over a considerable period of time, consists of a novel 'intelligent' triggering procedure in which the GF is triggered at a user-chosen 'position' in the reproducible drift-cycle of the WM-DLAS background signal. The new methodology makes also use of 'higher-than-normal' detection harmonics, i.e. 4f or 6f, since these previously have shown to have a higher signal-to-background ratio than 2f-detection when the background signals originates from thin etalons. The results show that this new combined background-drift-reducing methodology improves the limit of detection of the WM-DLAS technique used with a window-equipped GF by several orders of magnitude as compared to ordinary 2f-detection, resulting in a limit of detection for a window-equipped GF that is similar to that of an open GF

  2. Establishing the behavioural limits for countershaded camouflage.

    Science.gov (United States)

    Penacchio, Olivier; Harris, Julie M; Lovell, P George

    2017-10-20

    Countershading is a ubiquitous patterning of animals whereby the side that typically faces the highest illumination is darker. When tuned to specific lighting conditions and body orientation with respect to the light field, countershading minimizes the gradient of light the body reflects by counterbalancing shadowing due to illumination, and has therefore classically been thought of as an adaptation for visual camouflage. However, whether and how crypsis degrades when body orientation with respect to the light field is non-optimal has never been studied. We tested the behavioural limits on body orientation for countershading to deliver effective visual camouflage. We asked human participants to detect a countershaded target in a simulated three-dimensional environment. The target was optimally coloured for crypsis in a reference orientation and was displayed at different orientations. Search performance dramatically improved for deviations beyond 15 degrees. Detection time was significantly shorter and accuracy significantly higher than when the target orientation matched the countershading pattern. This work demonstrates the importance of maintaining body orientation appropriate for the displayed camouflage pattern, suggesting a possible selective pressure for animals to orient themselves appropriately to enhance crypsis.

  3. Augmented Reality for Real-Time Detection and Interpretation of Colorimetric Signals Generated by Paper-Based Biosensors.

    Science.gov (United States)

    Russell, Steven M; Doménech-Sánchez, Antonio; de la Rica, Roberto

    2017-06-23

    Colorimetric tests are becoming increasingly popular in point-of-need analyses due to the possibility of detecting the signal with the naked eye, which eliminates the utilization of bulky and costly instruments only available in laboratories. However, colorimetric tests may be interpreted incorrectly by nonspecialists due to disparities in color perception or a lack of training. Here we solve this issue with a method that not only detects colorimetric signals but also interprets them so that the test outcome is understandable for anyone. It consists of an augmented reality (AR) app that uses a camera to detect the colored signals generated by a nanoparticle-based immunoassay, and that yields a warning symbol or message when the concentration of analyte is higher than a certain threshold. The proposed method detected the model analyte mouse IgG with a limit of detection of 0.3 μg mL -1 , which was comparable to the limit of detection afforded by classical densitometry performed with a nonportable device. When adapted to the detection of E. coli, the app always yielded a "hazard" warning symbol when the concentration of E. coli in the sample was above the infective dose (10 6 cfu mL -1 or higher). The proposed method could help nonspecialists make a decision about drinking from a potentially contaminated water source by yielding an unambiguous message that is easily understood by anyone. The widespread availability of smartphones along with the inexpensive paper test that requires no enzymes to generate the signal makes the proposed assay promising for analyses in remote locations and developing countries.

  4. Current State of the Art: Management of Higher Risk Myelodysplastic Syndromes.

    Science.gov (United States)

    Komrokji, Rami S

    2016-08-01

    The higher risk myelodysplastic syndrome (MDS) patients, defined by the International Prognostic Scoring System (IPSS) as intermediate-2 or high-risk groups, compromise a third of MDS patients who have an expected survival of less than 1.5 years. Our ability to better define higher risk MDS improved with the proposal of new clinical risk models such as the revised IPSS and by integration of molecular data, including somatic gene mutations. Allogeneic hematopoietic stem-cell transplantation (AHSCT) remains the only curative option. In higher risk MDS patients, proceeding early with AHSCT is associated with maximum survival gain. The decision to pursue AHSCT is individualized according to disease risk, comorbidities, and functional status. The role of therapy before AHSCT remains controversial, and the role of post-AHSCT maintenance is evolving. Hypomethylating agents are the only medications that alter the natural history of the disease. Azacitidine is the only drug reported to improve overall survival in higher risk MDS patients. Appropriate use and assessment of response is key for assuring patients benefit of such limited options. Treatment after failure of hypomethylating agents is an unmet need. The role of detectable somatic gene mutations in prognosis and tailoring therapy continue to emerge. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Three Decades of Implementation Research in Higher Education: Limitations and Prospects of Theory Development

    Science.gov (United States)

    Kohoutek, Jan

    2013-01-01

    The article adopts a comparative approach to review three periods of theory development in research into higher education policy implementation. Given the conceptual affinity between Cerych and Sabatier's 1986 seminal study into higher education policy implementation and public policy implementation theory, the field of public policy is chosen for…

  6. Statistical data treatment of environmental radiological measurements extracted by the CSN and submitted to a lower limit of detection

    International Nuclear Information System (INIS)

    Felipe, A.; Martin, M.; Valdes, T.

    1992-01-01

    The quantification of radiological environmental contamination is usually carried out by mean of sample measurements around the emission points. These data are submitted to the so called Lower Limit of Detection which makes data to be statistically censored. The following topics have been included in our work: (a) Correction of mean values of the radiological contamination levels by the estimation of its distribution. (b) Development of the computer programs to carry out the former correction of estimators. (c) Estimation of the existing correlation among the different types of measurements. (author)

  7. Optimizing detectability

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    HPLC is useful for trace and ultratrace analyses of a variety of compounds. For most applications, HPLC is useful for determinations in the nanogram-to-microgram range; however, detection limits of a picogram or less have been demonstrated in certain cases. These determinations require state-of-the-art capability; several examples of such determinations are provided in this chapter. As mentioned before, to detect and/or analyze low quantities of a given analyte at submicrogram or ultratrace levels, it is necessary to optimize the whole separation system, including the quantity and type of sample, sample preparation, HPLC equipment, chromatographic conditions (including column), choice of detector, and quantitation techniques. A limited discussion is provided here for optimization based on theoretical considerations, chromatographic conditions, detector selection, and miscellaneous approaches to detectability optimization. 59 refs

  8. Accounting for detectability in fish distribution models: an approach based on time-to-first-detection

    Directory of Open Access Journals (Sweden)

    Mário Ferreira

    2015-12-01

    Full Text Available Imperfect detection (i.e., failure to detect a species when the species is present is increasingly recognized as an important source of uncertainty and bias in species distribution modeling. Although methods have been developed to solve this problem by explicitly incorporating variation in detectability in the modeling procedure, their use in freshwater systems remains limited. This is probably because most methods imply repeated sampling (≥ 2 of each location within a short time frame, which may be impractical or too expensive in most studies. Here we explore a novel approach to control for detectability based on the time-to-first-detection, which requires only a single sampling occasion and so may find more general applicability in freshwaters. The approach uses a Bayesian framework to combine conventional occupancy modeling with techniques borrowed from parametric survival analysis, jointly modeling factors affecting the probability of occupancy and the time required to detect a species. To illustrate the method, we modeled large scale factors (elevation, stream order and precipitation affecting the distribution of six fish species in a catchment located in north-eastern Portugal, while accounting for factors potentially affecting detectability at sampling points (stream depth and width. Species detectability was most influenced by depth and to lesser extent by stream width and tended to increase over time for most species. Occupancy was consistently affected by stream order, elevation and annual precipitation. These species presented a widespread distribution with higher uncertainty in tributaries and upper stream reaches. This approach can be used to estimate sampling efficiency and provide a practical framework to incorporate variations in the detection rate in fish distribution models.

  9. Upper limits to the detection of ammonia from protoplanetary disks around HL Tauri and L1551-IRS 5

    Science.gov (United States)

    Gomez, Jose F.; Torrelles, Jose M.; Ho, Paul T. P.; Rodriguez, Luis F.; Canto, Jorge

    1993-01-01

    We present NH3(1, 1) and (2, 2) observations of the young stellar sources HL Tau and L1551-IRS 5 using the VLA in its B-configuration, which provides an angular resolution of about 0.4 arcsec (about 50 AU at 140 pc) at 1.3 cm wavelength. Our goal was to detect and resolve circumstellar molecular disks with radius of the order of 100 AU around these two sources. No ammonia emission was detected toward either of them. The 3-sigma levels were 2.7 mJy/beam and 3.9 mJy/beam for HL Tau and L1551-IRS 5, respectively, with a velocity resolution of about 5 km/s. With this nondetection, we estimate upper limits to the mass of the proposed protoplanetary molecular disks (within a radius of 10 AU from the central stars) on the order of 0.02/(X(NH3)/10 exp -8) solar mass for HL Tau and 0.1/(X(NH3)/10 exp -8) solar mass for L1551-IRS 5.

  10. Detection sensitivity of laser-induced breakdown spectroscopy for Cr II in liquid samples

    International Nuclear Information System (INIS)

    Rai, Nilesh K.; Rai, Awadhesh K.; Kumar, Akshaya; Thakur, Surya N.

    2008-01-01

    The performance of laser-induced breakdown spectroscopy (LIBS) has been evaluated for detection of toxic metals such as Cr in water. Pure aqueous solutions (unitary matrix) with variable Cr concentration were used to construct calibration curves and to estimate the LIBS limit of detection (LOD). The calibration curves for Cr in a binary matrix (Cr plus Cd) and a tertiary matrix (Cr plus Cd and Co) were used to evaluate the matrix effect on the LOD. The LOD for Cr was found to be 1.1, 1.5, and 2.0 ppm (parts in 10 6 ) in a unitary, binary, and tertiary matrix, respectively. Once calibrated, the system was utilized for the detection and quantification of the Cr in tannery wastewater collected from different locations in the industrial area of Kanpur, India, where Cr concentrations were determined to be far higher than the U.S. Environmental Protection Agency safe drinking water limit of 0.05 ppm

  11. External and internal limitations in amplitude-modulation processing

    DEFF Research Database (Denmark)

    Ewert, Stephan; Dau, Torsten

    2004-01-01

    Three experiments are presented to explore the relative role of "external" signal variability and "internal" resolution limitations of the auditory system in the detection and discrimination of amplitude modulations (AM). In the first experiment, AM-depth discrimination performance was determined......-filterbank models. The predictions revealed that AM-depth discrimination and AM detection are limited by a combination of the external signal variability and an internal "Weber-fraction" noise process....

  12. Possibilities for decreasing detection limits of analytical methods for determination of transformation products of unsymmetrical dimethylhydrazine in environmental samples

    Directory of Open Access Journals (Sweden)

    Bulat Kenessov

    2015-12-01

    Full Text Available Most rockets of middle and heavy class launched from Kazakhstan, Russia, China and other countries still use highly toxic unsymmetrical dimethylhydrazine (UDMH as a liquid propellant. Study of migration, distribution and accumulation of UDMH transformation products in environment and human health impact assessment of space rocket activity are currently complicated due to the absence of analytical methods allowing detection of trace concentrations of these compounds in analyzed samples. This paper reviews methods and approaches, which can be applied for development of such methods. Detection limits at a part-per-trillion (ppt level may be achieved using most selective and sensitive methods based on gas or liquid chromatography in combination of tandem or high-resolution mass spectrometry. In addition, 1000-fold concentration of samples or integrated sample preparation methods, e.g., dynamic headspace extraction, are required. Special attention during development and application of such methods must be paid to purity of laboratory air, reagents, glassware and analytical instruments.

  13. Protein biomarkers on tissue as imaged via MALDI mass spectrometry: A systematic approach to study the limits of detection.

    Science.gov (United States)

    van de Ven, Stephanie M W Y; Bemis, Kyle D; Lau, Kenneth; Adusumilli, Ravali; Kota, Uma; Stolowitz, Mark; Vitek, Olga; Mallick, Parag; Gambhir, Sanjiv S

    2016-06-01

    MALDI mass spectrometry imaging (MSI) is emerging as a tool for protein and peptide imaging across tissue sections. Despite extensive study, there does not yet exist a baseline study evaluating the potential capabilities for this technique to detect diverse proteins in tissue sections. In this study, we developed a systematic approach for characterizing MALDI-MSI workflows in terms of limits of detection, coefficients of variation, spatial resolution, and the identification of endogenous tissue proteins. Our goal was to quantify these figures of merit for a number of different proteins and peptides, in order to gain more insight in the feasibility of protein biomarker discovery efforts using this technique. Control proteins and peptides were deposited in serial dilutions on thinly sectioned mouse xenograft tissue. Using our experimental setup, coefficients of variation were biomarkers and a new benchmarking strategy that can be used for comparing diverse MALDI-MSI workflows. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. High gain gas microstrip detectors for soft x-ray detection

    International Nuclear Information System (INIS)

    Bateman, J.; Barlow, R.; Derbyshire, G.

    2001-01-01

    This report describes development work in which systematic changes in the pitch of the electrode pattern of a Gas Microstrip Detector are explored in the search for higher avalanche gains and enhanced stability. With the cathode width set to half of the pitch, gas gains of >50 000 are comfortably attainable with low detector noise so that x-rays can potentially be detected down to the limit of a single x-ray-produced photoelectron. (author)

  15. Limiting characteristics of the superconducting fault current limiter applied to the neutral line of conventional transformer

    International Nuclear Information System (INIS)

    Im, I.G.; Choi, H.S.; Jung, B.I.

    2013-01-01

    Highlights: •Fault current limiter was used a high-speed interrupter. •High-speed interrupter was operated to bypass to the current limiter line. •The size of the fault current was limited to about 80% after the fault occurred. •The fault current was limited quickly within a half-cycle after the fault occurred. -- Abstract: The increased electricity demands influenced by the recent industrial development make the electric power distribution system more comprehensive, and the risks are high to cause failures to steady state electric line due to the extended range of fault at the time of fault occurrence. Also, the high performance and the high precision electric appliances that sensitive to switching surge and fault current expose vulnerability of reduced life span and increased fault occurrence ratio. Therefore, this thesis analyzed the fault limiting characteristics by the fault types by applying the superconducting fault current limiter to the neutral line of the transformer in order to reduce the fault currents that flow such high performance appliances. A current transformer (CT) that detects the fault current in the simulated power distribution system, a switching control system that is self-developed and a transformer are used in constructing a circuit. When a fault occurs, the initial fault current is restricted by the superconducting fault current limiter and simultaneously detours the fault current by operating the SCR contact of the switching control system through the detection by CT. This thesis analyzed the limiting characteristics of the superconducting fault current limiter that are applied to the neutral line of the transformer by the fault types

  16. Limiting characteristics of the superconducting fault current limiter applied to the neutral line of conventional transformer

    Energy Technology Data Exchange (ETDEWEB)

    Im, I.G., E-mail: asiligo@gmail.com; Choi, H.S., E-mail: hyosang@chosun.ac.kr; Jung, B.I.

    2013-11-15

    Highlights: •Fault current limiter was used a high-speed interrupter. •High-speed interrupter was operated to bypass to the current limiter line. •The size of the fault current was limited to about 80% after the fault occurred. •The fault current was limited quickly within a half-cycle after the fault occurred. -- Abstract: The increased electricity demands influenced by the recent industrial development make the electric power distribution system more comprehensive, and the risks are high to cause failures to steady state electric line due to the extended range of fault at the time of fault occurrence. Also, the high performance and the high precision electric appliances that sensitive to switching surge and fault current expose vulnerability of reduced life span and increased fault occurrence ratio. Therefore, this thesis analyzed the fault limiting characteristics by the fault types by applying the superconducting fault current limiter to the neutral line of the transformer in order to reduce the fault currents that flow such high performance appliances. A current transformer (CT) that detects the fault current in the simulated power distribution system, a switching control system that is self-developed and a transformer are used in constructing a circuit. When a fault occurs, the initial fault current is restricted by the superconducting fault current limiter and simultaneously detours the fault current by operating the SCR contact of the switching control system through the detection by CT. This thesis analyzed the limiting characteristics of the superconducting fault current limiter that are applied to the neutral line of the transformer by the fault types.

  17. A comparison of the sensitivities of detection of Plasmodium falciparum gametocytes by magnetic fractionation, thick blood film microscopy, and RT-PCR

    Directory of Open Access Journals (Sweden)

    St-Pierre Tim G

    2009-05-01

    Full Text Available Abstract Background The magnetic properties of Plasmodium-infected erythrocytes have been exploited for different clinical and research purposes. A recent study in a rural clinical setting in Papua New Guinea has demonstrated that Plasmodium falciparum gametocyte detection is facilitated by magnetic deposition microscopy but no study has yet determined the relative sensitivity and limit of detection of a magnetic fractionation technique. The present study compares the detection limit and sensitivity of a technique based on the use of commercially available magnetic fractionation columns with those for thick blood film microscopy and reverse transcriptase polymerase chain reaction (RT-PCR methods. Methods Gametocyte detection in six series of dilutions of cultured P. falciparum parasites with known gametocytaemia was conducted using magnetic fractionation, thick blood film, and RT-PCR techniques. Results The preparations obtained by the magnetic fractionation method were of thin film quality allowing easy gametocyte identification by light microscopy. Magnetic fractionation had a higher sensitivity and approximately two orders of magnitude better limit of detection than thick blood film microscopy. Gametocytes were also more readily detectable on the magnetically fractionated preparations. Magnetic fractionation had a similar limit of detection to that of RT-PCR. Conclusion Magnetic fractionation is a highly sensitive and convenient method for gametocyte detection in comparison with the standard thick blood film and RT-PCR methods, and could readily be adapted to field application.

  18. Detection limit improvements forecasted at CTBTO IMS radionuclide stations based on size separation of aerosols by aerodynamic diameter

    International Nuclear Information System (INIS)

    Biegalski, S.; Ezekoye, O.A.; Pena, J.M.; Waye, S.; Pickering, M.

    2008-01-01

    Studies show that aerosols with natural activity have an aerodynamic diameter in the range of 0.1 to 1 μm. In contrast, nuclear explosions generally produce radioactive aerosols with aerodynamic diameters less than 0.1 μm and greater than 1 μm. These differences in aerosol sizes are quite fortuitous because they allow aerosol aerodynamic diameter to be utilized as a physical property to separate aerosols of natural origin from those produced in a nuclear explosion. Data collected in Austin, TX and at U.S. CTBT IMS radionuclide stations have been utilized to forecast detection limit improvements possible given an aerosol size separation capability. (author)

  19. Investigation of the limitations of the highly pixilated CdZnTe detector for PET applications.

    Science.gov (United States)

    Komarov, Sergey; Yin, Yongzhi; Wu, Heyu; Wen, Jie; Krawczynski, Henric; Meng, Ling-Jian; Tai, Yuan-Chuan

    2012-11-21

    We are investigating the feasibility of a high resolution positron emission tomography (PET) insert device based on the CdZnTe detector with 350 µm anode pixel pitch to be integrated into a conventional animal PET scanner to improve its image resolution. In this paper, we have used a simplified version of the multi pixel CdZnTe planar detector, 5 mm thick with 9 anode pixels only. This simplified 9 anode pixel structure makes it possible to carry out experiments without a complete application-specific integrated circuits readout system that is still under development. Special attention was paid to the double pixel (or charge sharing) detections. The following characteristics were obtained in experiment: energy resolution full-width-at-half-maximum (FWHM) is 7% for single pixel and 9% for double pixel photoelectric detections of 511 keV gammas; timing resolution (FWHM) from the anode signals is 30 ns for single pixel and 35 ns for double pixel detections (for photoelectric interactions only the corresponding values are 20 and 25 ns); position resolution is 350 µm in x,y-plane and ∼0.4 mm in depth-of-interaction. The experimental measurements were accompanied by Monte Carlo (MC) simulations to find a limitation imposed by spatial charge distribution. Results from MC simulations suggest the limitation of the intrinsic spatial resolution of the CdZnTe detector for 511 keV photoelectric interactions is 170 µm. The interpixel interpolation cannot recover the resolution beyond the limit mentioned above for photoelectric interactions. However, it is possible to achieve higher spatial resolution using interpolation for Compton scattered events. Energy and timing resolution of the proposed 350 µm anode pixel pitch detector is no better than 0.6% FWHM at 511 keV, and 2 ns FWHM, respectively. These MC results should be used as a guide to understand the performance limits of the pixelated CdZnTe detector due to the underlying detection processes, with the understanding of

  20. Quantile regression for the statistical analysis of immunological data with many non-detects.

    Science.gov (United States)

    Eilers, Paul H C; Röder, Esther; Savelkoul, Huub F J; van Wijk, Roy Gerth

    2012-07-07

    Immunological parameters are hard to measure. A well-known problem is the occurrence of values below the detection limit, the non-detects. Non-detects are a nuisance, because classical statistical analyses, like ANOVA and regression, cannot be applied. The more advanced statistical techniques currently available for the analysis of datasets with non-detects can only be used if a small percentage of the data are non-detects. Quantile regression, a generalization of percentiles to regression models, models the median or higher percentiles and tolerates very high numbers of non-detects. We present a non-technical introduction and illustrate it with an implementation to real data from a clinical trial. We show that by using quantile regression, groups can be compared and that meaningful linear trends can be computed, even if more than half of the data consists of non-detects. Quantile regression is a valuable addition to the statistical methods that can be used for the analysis of immunological datasets with non-detects.

  1. On the limitations introduced by energy spread in elastic recoil detection analysis

    International Nuclear Information System (INIS)

    Szilagyi, E.

    2001-01-01

    Improvements in experimental techniques have led to monolayer depth resolution in heavy ion elastic recoil detection analysis (HI-ERDA). Evaluation of the spectra, however, is not trivial. The spectra, using even the best experimental set-up, are subject to finite energy resolution of both extrinsic and intrinsic origin. A proper account for energy spread is necessary to extract the correct depth profile from the measured spectra. With calculation of the correct energy (or depth) resolution of a given method, one can decide in advance whether or not the method will resolve details of interest in the depth profile. To achieve the best depth resolution, it is also possible to find optimum parameters for the experiments. The limitations introduced by the energy spread effects are discussed. An example for simulation is shown for high energy resolution HI-ERDA measurements. Satisfactory agreement between the simulated and the measured HI-ERDA spectra taken by 60 MeV 127 I 23+ ions on highly oriented pyrolythic graphite (HOPG) sample is found, in spite of the non-equilibrium charge state of the recoils and the difference in the stopping powers caused by the given charge state of the incident ion and the recoil, which are not taken into account. To achieve more precise data evaluation these effects should be included in simulation codes, or all the subspectra corresponding to different recoils charge states should be measured and summed

  2. On the limitations introduced by energy spread in elastic recoil detection analysis

    Energy Technology Data Exchange (ETDEWEB)

    Szilagyi, E. E-mail: szilagyi@rmki.kfki.hu

    2001-07-01

    Improvements in experimental techniques have led to monolayer depth resolution in heavy ion elastic recoil detection analysis (HI-ERDA). Evaluation of the spectra, however, is not trivial. The spectra, using even the best experimental set-up, are subject to finite energy resolution of both extrinsic and intrinsic origin. A proper account for energy spread is necessary to extract the correct depth profile from the measured spectra. With calculation of the correct energy (or depth) resolution of a given method, one can decide in advance whether or not the method will resolve details of interest in the depth profile. To achieve the best depth resolution, it is also possible to find optimum parameters for the experiments. The limitations introduced by the energy spread effects are discussed. An example for simulation is shown for high energy resolution HI-ERDA measurements. Satisfactory agreement between the simulated and the measured HI-ERDA spectra taken by 60 MeV {sup 127}I{sup 23+} ions on highly oriented pyrolythic graphite (HOPG) sample is found, in spite of the non-equilibrium charge state of the recoils and the difference in the stopping powers caused by the given charge state of the incident ion and the recoil, which are not taken into account. To achieve more precise data evaluation these effects should be included in simulation codes, or all the subspectra corresponding to different recoils charge states should be measured and summed.

  3. Limited scleroderma and early detection of visceral changes

    International Nuclear Information System (INIS)

    Kalyuzhnaya, L.D.; Potsibina, V.V.; Stychinskaya, L.P.; Turik, N.V.

    1989-01-01

    The state of liver, kidneys, osteoarticular apparatus at the early stages of development of limited scleroderma and with the exclusion of visceral changes on the basis of clinical-laboratory studies is investigated. 11 patients with scleroderma in the age of 7-18 years were examined. Osteoscintigraphy with 99m TC-phosphone and dynamic scintigraphy of kidneys without additional introduction of RF, and hepatocholecyctoscintigraphy with 99m tc-HIPA of the patients were realized. The conclusion is made that radionuclide investigation methods permit to reveal various visceral changes, which are not recognizable by clinical methods

  4. Detection of maximum loadability limits and weak buses using Chaotic PSO considering security constraints

    International Nuclear Information System (INIS)

    Acharjee, P.; Mallick, S.; Thakur, S.S.; Ghoshal, S.P.

    2011-01-01

    Highlights: → The unique cost function is derived considering practical Security Constraints. → New innovative formulae of PSO parameters are developed for better performance. → The inclusion and implementation of chaos in PSO technique is original and unique. → Weak buses are identified where FACTS devices can be implemented. → The CPSO technique gives the best performance for all the IEEE standard test systems. - Abstract: In the current research chaotic search is used with the optimization technique for solving non-linear complicated power system problems because Chaos can overcome the local optima problem of optimization technique. Power system problem, more specifically voltage stability, is one of the practical examples of non-linear, complex, convex problems. Smart grid, restructured energy system and socio-economic development fetch various uncertain events in power systems and the level of uncertainty increases to a great extent day by day. In this context, analysis of voltage stability is essential. The efficient method to assess the voltage stability is maximum loadability limit (MLL). MLL problem is formulated as a maximization problem considering practical security constraints (SCs). Detection of weak buses is also important for the analysis of power system stability. Both MLL and weak buses are identified by PSO methods and FACTS devices can be applied to the detected weak buses for the improvement of stability. Three particle swarm optimization (PSO) techniques namely General PSO (GPSO), Adaptive PSO (APSO) and Chaotic PSO (CPSO) are presented for the comparative study with obtaining MLL and weak buses under different SCs. In APSO method, PSO-parameters are made adaptive with the problem and chaos is incorporated in CPSO method to obtain reliable convergence and better performances. All three methods are applied on standard IEEE 14 bus, 30 bus, 57 bus and 118 bus test systems to show their comparative computing effectiveness and

  5. The Generalized Higher Criticism for Testing SNP-Set Effects in Genetic Association Studies

    Science.gov (United States)

    Barnett, Ian; Mukherjee, Rajarshi; Lin, Xihong

    2017-01-01

    It is of substantial interest to study the effects of genes, genetic pathways, and networks on the risk of complex diseases. These genetic constructs each contain multiple SNPs, which are often correlated and function jointly, and might be large in number. However, only a sparse subset of SNPs in a genetic construct is generally associated with the disease of interest. In this article, we propose the generalized higher criticism (GHC) to test for the association between an SNP set and a disease outcome. The higher criticism is a test traditionally used in high-dimensional signal detection settings when marginal test statistics are independent and the number of parameters is very large. However, these assumptions do not always hold in genetic association studies, due to linkage disequilibrium among SNPs and the finite number of SNPs in an SNP set in each genetic construct. The proposed GHC overcomes the limitations of the higher criticism by allowing for arbitrary correlation structures among the SNPs in an SNP-set, while performing accurate analytic p-value calculations for any finite number of SNPs in the SNP-set. We obtain the detection boundary of the GHC test. We compared empirically using simulations the power of the GHC method with existing SNP-set tests over a range of genetic regions with varied correlation structures and signal sparsity. We apply the proposed methods to analyze the CGEM breast cancer genome-wide association study. Supplementary materials for this article are available online. PMID:28736464

  6. Reconstruction of the limit cycles by the delays method

    International Nuclear Information System (INIS)

    Castillo D, R.; Ortiz V, J.; Calleros M, G.

    2003-01-01

    The boiling water reactors (BWRs) are designed for usually to operate in a stable-lineal regime. In a limit cycle the behavior of the one system is no lineal-stable. In a BWR, instabilities of nuclear- thermohydraulics nature can take the reactor to a limit cycle. The limit cycles should to be avoided since the oscillations of power can cause thermal fatigue to the fuel and/or shroud. In this work the employment of the delays method is analyzed for its application in the detection of limit cycles in a nuclear power plant. The foundations of the method and it application to power signals to different operation conditions are presented. The analyzed signals are: to steady state, nuclear-thermohydraulic instability, a non linear transitory and, finally, failure of a controller plant . Among the main results it was found that the delays method can be applied to detect limit cycles in the power monitors of the BWR reactors. It was also found that the first zero of the autocorrelation function is an appropriate approach to select the delay in the detection of limit cycles, for the analyzed cases. (Author)

  7. Fuel Class Higher Alcohols

    KAUST Repository

    Sarathy, Mani

    2016-08-17

    This chapter focuses on the production and combustion of alcohol fuels with four or more carbon atoms, which we classify as higher alcohols. It assesses the feasibility of utilizing various C4-C8 alcohols as fuels for internal combustion engines. Utilizing higher-molecular-weight alcohols as fuels requires careful analysis of their fuel properties. ASTM standards provide fuel property requirements for spark-ignition (SI) and compression-ignition (CI) engines such as the stability, lubricity, viscosity, and cold filter plugging point (CFPP) properties of blends of higher alcohols. Important combustion properties that are studied include laminar and turbulent flame speeds, flame blowout/extinction limits, ignition delay under various mixing conditions, and gas-phase and particulate emissions. The chapter focuses on the combustion of higher alcohols in reciprocating SI and CI engines and discusses higher alcohol performance in SI and CI engines. Finally, the chapter identifies the sources, production pathways, and technologies currently being pursued for production of some fuels, including n-butanol, iso-butanol, and n-octanol.

  8. Time-limited optimal dynamics beyond the Quantum Speed Limit

    DEFF Research Database (Denmark)

    Gajdacz, Miroslav; Das, Kunal K.; Arlt, Jan

    2015-01-01

    The quantum speed limit sets the minimum time required to transfer a quantum system completely into a given target state. At shorter times the higher operation speed has to be paid with a loss of fidelity. Here we quantify the trade-off between the fidelity and the duration in a system driven......-off expressed in terms of the direct Hilbert velocity provides a robust prediction of the quantum speed limit and allows to adapt the control optimization such that it yields a predefined fidelity. The results are verified numerically in a multilevel system with a constrained Hamiltonian, and a classification...

  9. Molecularly imprinted fluorescent probe based on FRET for selective and sensitive detection of doxorubicin

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhifeng, E-mail: 897061147@qq.com [College of Chemistry and Materials Science, Hengyang Normal University, Key Laboratory of Functional Organometallic Materials of Hunan Province University, Hengyang 421008 (China); Deng, Peihong; Li, Junhua [College of Chemistry and Materials Science, Hengyang Normal University, Key Laboratory of Functional Organometallic Materials of Hunan Province University, Hengyang 421008 (China); Xu, Li [Department of Applied Chemistry, College of Materials and Energy, South China Agricultural University, Guangzhou 510642 (China); Tang, Siping [College of Chemistry and Materials Science, Hengyang Normal University, Key Laboratory of Functional Organometallic Materials of Hunan Province University, Hengyang 421008 (China)

    2017-04-15

    Highlights: • FRET-based molecularly imprinted probe for detection of doxorubicin was prepared. • The detection limit of the probe was 13.8 nM for doxorubicin. • The FRET-based probe had a higher selectivity for the template than ordinary MIMs. - Abstract: In this work, a new type of fluorescent probe for detection of doxorubicin has been constructed by the combined use of fluorescence resonance energy transfer (FRET) technology and molecular imprinting technique (MIT). Using doxorubicin as the template, the molecularly imprinted polymer thin layer was fabricated on the surfaces of carbon dot (CD) modified silica by sol-gel polymerization. The excitation energy of the fluorescent donor (CDs) could be transferred to the fluorescent acceptor (doxorubicin). The FRET based fluorescent probe demonstrated high sensitivity and selectivity for doxorubicin. The detection limit was 13.8 nM. The fluorescent probe was successfully applied for detecting doxorubicin in doxorubicin-spiked plasmas with a recovery of 96.8–103.8%, a relative standard deviation (RSD) of 1.3–2.8%. The strategy for construction of FRET-based molecularly imprinted materials developed in this work is very promising for analytical applications.

  10. Unobtrusive Deception Detection

    NARCIS (Netherlands)

    Elkins, Aaron; Zafeiriou, Stefanos; Pantic, Maja; Burgoon, Judee; Calvo, Rafael; D' Mello, Sidney; Gratch, Jonathan; Kappas, Arvid

    In response to national security needs and human deception detection limitations paired with advances in sensor and computing technology research into automated deception detection has increased in recent years. These technologies rely on psychological and communication theories of deception to

  11. Rapid Detection of Microorganisms Based on Active and Passive Modes of QCM

    Directory of Open Access Journals (Sweden)

    Zdeněk Farka

    2014-12-01

    Full Text Available Label-free immunosensors are well suited for detection of microorganisms because of their fast response and reasonable sensitivity comparable to infection doses of common pathogens. Active (lever oscillator and frequency counter and passive (impedance analyzer modes of quartz crystal microbalance (QCM were used and compared for rapid detection of three strains of E. coli. Different approaches for antibody immobilization were compared, the immobilization of reduced antibody using Sulfo‑SMCC was most effective achieving the limit of detection (LOD 8 × 104 CFU·mL−1 in 10 min. For the passive mode, software evaluating impedance characteristics in real-time was developed and used. Almost the same results were achieved using both active and passive modes confirming that the sensor properties are not limited by the frequency evaluation method but mainly by affinity of the antibody. Furthermore, reference measurements were done using surface plasmon resonance. Effect of condition of cells on signal was observed showing that cells ruptured by ultrasonication provided slightly higher signal changes than intact microbes.

  12. Compact quantum dot-antibody conjugates for FRET immunoassays with subnanomolar detection limits

    Science.gov (United States)

    Mattera, Lucia; Bhuckory, Shashi; Wegner, K. David; Qiu, Xue; Agnese, Fabio; Lincheneau, Christophe; Senden, Tim; Djurado, David; Charbonnière, Loïc J.; Hildebrandt, Niko; Reiss, Peter

    2016-05-01

    A novel two-step approach for quantum dot (QD) functionalization and bioconjugation is presented, which yields ultra-compact, stable, and highly luminescent antibody-QD conjugates suitable for use in FRET immunoassays. Hydrophobic InPZnS/ZnSe/ZnS (emission wavelength: 530 nm), CdSe/ZnS (605 nm), and CdSeTe/ZnS (705 nm) QDs were surface functionalized with zwitterionic penicillamine, enabling aqueous phase transfer under conservation of the photoluminescence properties. Post-functionalization with a heterobifunctional crosslinker, containing a lipoic acid group and a maleimide function, enabled the subsequent coupling to sulfhydryl groups of proteins. This was demonstrated by QD conjugation with fragmented antibodies (F(ab)). The obtained F(ab)-QD conjugates range among the smallest antibody-functionalized nanoprobes ever reported, with a hydrodynamic diameter coating for FRET could be demonstrated by an 6.2 and 2.5 fold improvement of the limit of detection (LOD) for PSA compared to commercially available hydrophilic QDs emitting at 605 and 705 nm, respectively. While the commercial QDs contain identical inorganic cores responsible for their fluorescence, they are coated with a comparably thick amphiphilic polymer layer leading to much larger hydrodynamic diameters (>26 nm without biomolecules). The LODs of 0.8 and 3.7 ng mL-1 obtained in 50 μL serum samples are below the clinical cut-off level of PSA (4 ng mL-1) and demonstrate their direct applicability in clinical diagnostics.A novel two-step approach for quantum dot (QD) functionalization and bioconjugation is presented, which yields ultra-compact, stable, and highly luminescent antibody-QD conjugates suitable for use in FRET immunoassays. Hydrophobic InPZnS/ZnSe/ZnS (emission wavelength: 530 nm), CdSe/ZnS (605 nm), and CdSeTe/ZnS (705 nm) QDs were surface functionalized with zwitterionic penicillamine, enabling aqueous phase transfer under conservation of the photoluminescence properties. Post

  13. Technical Note: The single particle soot photometer fails to reliably detect PALAS soot nanoparticles

    Directory of Open Access Journals (Sweden)

    M. Gysel

    2012-12-01

    density. By contrast, the BC mass per primary particle mainly determines whether fractal-like particles with low fractal dimension and very small primary particles are detectable, while their total BC mass has only a minor influence. This effect shifts the lower detection limit to much higher BC mass, or makes them completely undetectable. Consequently, care has to be taken when using the SP2 in applications dealing with loosely packed particles that have very small primary particles as building blocks.

  14. Retrospective observation on contribution and limitations of screening for breast cancer with mammography in Korea: detection rate of breast cancer and incidence rate of interval cancer of the breast.

    Science.gov (United States)

    Lee, Kunsei; Kim, Hyeongsu; Lee, Jung Hyun; Jeong, Hyoseon; Shin, Soon Ae; Han, Taehwa; Seo, Young Lan; Yoo, Youngbum; Nam, Sang Eun; Park, Jong Heon; Park, Yoo Mi

    2016-11-18

    The purpose of this study was to determine the benefits and limitations of screening for breast cancer using mammography. Descriptive design with follow-up was used in the study. Data from breast cancer screening and health insurance claim data were used. The study population consisted of all participants in breast cancer screening from 2009 to 2014. Crude detection rate, positive predictive value and sensitivity and specificity of breast cancer screening and, incidence rate of interval cancer of the breast were calculated. The crude detection rate of breast cancer screening per 100,000 participants increased from 126.3 in 2009 to 182.1 in 2014. The positive predictive value of breast cancer screening per 100,000 positives increased from 741.2 in 2009 to 1,367.9 in 2014. The incidence rate of interval cancer of the breast per 100,000 negatives increased from 51.7 in 2009 to 76.3 in 2014. The sensitivities of screening for breast cancer were 74.6% in 2009 and 75.1% in 2014 and the specificities were 83.1% in 2009 and 85.7% in 2014. To increase the detection rate of breast cancer by breast cancer screening using mammography, the participation rate should be higher and an environment where accurate mammography and reading can be performed and reinforcement of quality control are required. To reduce the incidence rate of interval cancer of the breast, it will be necessary to educate women after their 20s to perform self-examination of the breast once a month regardless of participation in screening for breast cancer.

  15. Sandwiched gold/PNIPAm/gold microstructures for smart plasmonics application: towards the high detection limit and Raman quantitative measurements.

    Science.gov (United States)

    Elashnikov, R; Mares, D; Podzimek, T; Švorčík, V; Lyutakov, O

    2017-08-07

    A smart plasmonic sensor, comprising a layer of a stimuli-responsive polymer sandwiched between two gold layers, is reported. As a stimuli-responsive material, a monolayer of poly(N-isopropylacrylamide) (PNIPAm) crosslinked globules is used. A quasi-periodic structure of the top gold layer facilitates efficient excitation and serves as a support for plasmon excitation and propagation. The intermediate layer of PNIPAm efficiently entraps targeted molecules from solutions. The sensor structure was optimized for efficient light focusing in the "active" PNIPAm layer. The optimization was based on the time-resolved finite-element simulations, which take into account the thickness of gold layers, size of PNIPAm globules and Raman excitation wavelength (780 nm). The prepared structures were characterized using SEM, AFM, UV-Vis refractometry and goniometry. Additional AFM scans were performed in water at two temperatures corresponding to the collapsed and swollen PNIPAm states. The Raman measurements demonstrate a high detection limit and perfect reproducibility of the Raman scattering signal for the prepared sensor. In addition, the use of created SERS structures for the detection of relevant molecules in the medical, biological and safety fields was demonstrated.

  16. SISGR: Room Temperature Single-Molecule Detection and Imaging by Stimulated Emission Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Xiaoliang Sunney [Harvard Univ., Cambridge, MA (United States). Dept. of Chemistry and Chemical Biology

    2017-03-13

    Single-molecule spectroscopy has made considerable impact on many disciplines including chemistry, physics, and biology. To date, most single-molecule spectroscopy work is accomplished by detecting fluorescence. On the other hand, many naturally occurring chromophores, such as retinal, hemoglobin and cytochromes, do not have detectable fluorescence. There is an emerging need for single-molecule spectroscopy techniques that do not require fluorescence. In the last proposal period, we have successfully demonstrated stimulated emission microscopy, single molecule absorption, and stimulated Raman microscopy based on a high-frequency modulation transfer technique. These first-of-a- kind new spectroscopy/microscopy methods tremendously improved our ability to observe molecules that fluorescence weakly, even to the limit of single molecule detection for absorption measurement. All of these methods employ two laser beams: one (pump beam) excites a single molecule to a real or virtual excited state, and the other (probe beam) monitors the absorption/emission property of the single. We extract the intensity change of the probe beam with high sensitivity by implementing a high-frequency phase-sensitive detection scheme, which offers orders of magnitude improvement in detection sensitivity over direct absorption/emission measurement. However, single molecule detection based on fluorescence or absorption is fundamentally limited due to their broad spectral response. It is important to explore other avenues in single molecule detection and imaging which provides higher molecular specificity for studying a wide variety of heterogeneous chemical and biological systems. This proposal aimed to achieve single-molecule detection sensitivity with near resonance stimulated Raman scattering (SRS) microscopy. SRS microscopy was developed in our lab as a powerful technique for imaging heterogeneous samples based on their intrinsic vibrational contrasts, which provides much higher molecular

  17. REANALYSIS OF F-STATISTIC GRAVITATIONAL-WAVE SEARCHES WITH THE HIGHER CRITICISM STATISTIC

    International Nuclear Information System (INIS)

    Bennett, M. F.; Melatos, A.; Delaigle, A.; Hall, P.

    2013-01-01

    We propose a new method of gravitational-wave detection using a modified form of higher criticism, a statistical technique introduced by Donoho and Jin. Higher criticism is designed to detect a group of sparse, weak sources, none of which are strong enough to be reliably estimated or detected individually. We apply higher criticism as a second-pass method to synthetic F-statistic and C-statistic data for a monochromatic periodic source in a binary system and quantify the improvement relative to the first-pass methods. We find that higher criticism on C-statistic data is more sensitive by ∼6% than the C-statistic alone under optimal conditions (i.e., binary orbit known exactly) and the relative advantage increases as the error in the orbital parameters increases. Higher criticism is robust even when the source is not monochromatic (e.g., phase-wandering in an accreting system). Applying higher criticism to a phase-wandering source over multiple time intervals gives a ∼> 30% increase in detectability with few assumptions about the frequency evolution. By contrast, in all-sky searches for unknown periodic sources, which are dominated by the brightest source, second-pass higher criticism does not provide any benefits over a first-pass search.

  18. Free transfer, limited mobility: A decade of higher education reform in Egypt and Morocco

    OpenAIRE

    Florian Kohstall

    2012-01-01

    This article aims to demonstrate how countries with a relative low performance in higher education like Egypt and Morocco, are informed and worked by the forces of internationalization in this domain. It compares the path of university reforms in both countries over the last decade, from their emergence on the agenda to their implementation. Through the lenses of a public policy approach it illustrates how higher education is subject to a complex negotiation process between international orga...

  19. Monitoring of Non-Ferrous Wear Debris in Hydraulic Oil by Detecting the Equivalent Resistance of Inductive Sensors

    Directory of Open Access Journals (Sweden)

    Lin Zeng

    2018-03-01

    Full Text Available Wear debris in hydraulic oil contains important information on the operation of equipment, which is important for condition monitoring and fault diagnosis in mechanical equipment. A micro inductive sensor based on the inductive coulter principle is presented in this work. It consists of a straight micro-channel and a 3-D solenoid coil wound on the micro-channel. Instead of detecting the inductance change of the inductive sensor, the equivalent resistance change of the inductive sensor is detected for non-ferrous particle (copper particle monitoring. The simulation results show that the resistance change rate caused by the presence of copper particles is greater than the inductance change rate. Copper particles with sizes ranging from 48 μm to 150 μm were used in the experiment, and the experimental results are in good agreement with the simulation results. By detecting the inductive change of the micro inductive sensor, the detection limit of the copper particles only reaches 70 μm. However, the detection limit can be improved to 48 μm by detecting the equivalent resistance of the inductive sensor. The equivalent resistance method was demonstrated to have a higher detection accuracy than conventional inductive detection methods for non-ferrous particle detection in hydraulic oil.

  20. Rapid Methods for the Detection of Foodborne Bacterial Pathogens: Principles, Applications, Advantages and Limitations

    Directory of Open Access Journals (Sweden)

    Law eJodi Woan-Fei

    2015-01-01

    Full Text Available The incidence of foodborne diseases has increased over the years and resulted in major public health problem globally. Foodborne pathogens can be found in various foods and it is important to detect foodborne pathogens to provide safe food supply and to prevent foodborne diseases. The conventional methods used to detect foodborne pathogen are time consuming and laborious. Hence, a variety of methods have been developed for rapid detection of foodborne pathogens as it is required in many food analyses. Rapid detection methods can be categorized into nucleic acid-based, biosensor-based and immunological-based methods. This review emphasizes on the principles and application of recent rapid methods for the detection of foodborne bacterial pathogens. Detection methods included are simple polymerase chain reaction (PCR, multiplex PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA, loop-mediated isothermal amplification (LAMP and oligonucleotide DNA microarray which classified as nucleic acid-based methods; optical, electrochemical and mass-based biosensors which classified as biosensor-based methods; enzyme-linked immunosorbent assay (ELISA and lateral flow immunoassay which classified as immunological-based methods. In general, rapid detection methods are generally time-efficient, sensitive, specific and labor-saving. The developments of rapid detection methods are vital in prevention and treatment of foodborne diseases.

  1. Limit of detection in the presence of instrumental and non-instrumental errors: study of the possible sources of error and application to the analysis of 41 elements at trace levels by inductively coupled plasma-mass spectrometry technique

    International Nuclear Information System (INIS)

    Badocco, Denis; Lavagnini, Irma; Mondin, Andrea; Tapparo, Andrea; Pastore, Paolo

    2015-01-01

    In this paper the detection limit was estimated when signals were affected by two error contributions, namely instrumental errors and operational-non-instrumental errors. The detection limit was theoretically obtained following the hypothesis testing schema implemented with the calibration curve methodology. The experimental calibration design was based on J standards measured I times with non-instrumental errors affecting each standard systematically but randomly among the J levels. A two-component variance regression was performed to determine the calibration curve and to define the detection limit in these conditions. The detection limit values obtained from the calibration at trace levels of 41 elements by ICP-MS resulted larger than those obtainable from a one component variance regression. The role of the reagent impurities on the instrumental errors was ascertained and taken into account. Environmental pollution was studied as source of non-instrumental errors. The environmental pollution role was evaluated by Principal Component Analysis technique (PCA) applied to a series of nine calibrations performed in fourteen months. The influence of the seasonality of the environmental pollution on the detection limit was evidenced for many elements usually present in the urban air particulate. The obtained results clearly indicated the need of using the two-component variance regression approach for the calibration of all the elements usually present in the environment at significant concentration levels. - Highlights: • Limit of detection was obtained considering a two variance component regression. • Calibration data may be affected by instrumental and operational conditions errors. • Calibration model was applied to determine 41 elements at trace level by ICP-MS. • Non instrumental errors were evidenced by PCA analysis

  2. Multielement detection limits and sample nebulization efficiencies of an improved ultrasonic nebulizer and a conventional pneumatic nebulizer in inductively coupled plasma-atomic emission spectrometry

    International Nuclear Information System (INIS)

    Olson, K.W.; Haas, W.J. Jr.; Fassel, V.A.

    1977-01-01

    Two important aspects of the analytical performance of a newly developed ultrasonic nebulizer and a specially designed pneumatic nebulizer have been compared for use in inductively coupled plasma--atomic emission spectroscopy (ICP-AES). The ultrasonic nebulizer, when combined with a conventional aerosol desolvation apparatus, provided an order of magnitude or more improvement in simultaneous multielement detection limits as compared to those obtained when the pneumatic nebulizer was used either with or without desolvation. Application of a novel method for direct measurement of the overall efficiency of nebulization to the two systems showed that an approximately tenfold greater rate of sample delivery to the plasma torch was primarily responsible for the superior detection limits afforded by the ultrasonic nebulizer. A unique feature of the ultrasonic nebulizer described is the protection against chemical attack which is achieved by completely enclosing the transducer in an acoustically coupled borosilicate glass cylinder. Direct sample introduction, convenient sample change, and rapid cleanout are other important characteristics of the system which make it an attractive alternate to pneumatic nebulizer systems

  3. Conceptualizing and Assessing Higher-Order Thinking in Reading

    Science.gov (United States)

    Afflerbach, Peter; Cho, Byeong-Young; Kim, Jong-Yun

    2015-01-01

    Students engage in higher-order thinking as they read complex texts and perform complex reading-related tasks. However, the most consequential assessments, high-stakes tests, are currently limited in providing information about students' higher-order thinking. In this article, we describe higher-order thinking in relation to reading. We provide a…

  4. Older Adults' Motivation to Learn in Higher Education

    Science.gov (United States)

    Lin, Yi-Yin

    2011-01-01

    A limited amount of literature has discussed older adults in formal education, especially their motivations to learn in higher education. This study aims to understand older adults' learning in the context of higher education. Specifically, this study argues that higher education can function as a stimulating learning environment that helps older…

  5. Photoinduced triplet-state electron transfer of platinum porphyrin: a one-step direct method for sensing iodide with an unprecedented detection limit

    KAUST Repository

    Masih, Dilshad

    2015-02-05

    Here, we report for the first time a one-step direct method for sensing halides in aqueous solution using phosphorescence quenching of platinum-cationic porphyrin. This method offers an easy, rapid, environmentally friendly, ultra-sensitive (with a previously unattained detection limit of 1 × 10−12 M) and economical method for the determination of iodide. To fully understand the reaction mechanism responsible for the phosphorescence quenching process, we have employed cutting-edge time-resolved laser spectroscopy with broadband capabilities.

  6. Performance of blue-yellow screening test for antimicrobial detection in ovine milk.

    Science.gov (United States)

    Linage, B; Gonzalo, C; Carriedo, J A; Asensio, J A; Blanco, M A; De La Fuente, L F; San Primitivo, F

    2007-12-01

    Drug residues in milk are important because of public health and industrial implications. The detection limits of 25 antimicrobial agents were determined by the blue-yellow screening method in ovine milk. For each drug, 8 concentrations were tested on 20 ovine milk samples from individual ewes in midlactation. Detection limits determined by means of logistic regression were below European Union maximum residue limits (EU-MRL) for penicillin G (3 to 4 microg/kg), ceftiofur (96 to 107 microg/kg), framycetin (720 to 781 microg/kg), neomycin (915 to 1,084 microg/kg), and tylosin (44 to 51 microg/kg). Detection limits for ampicillin (5 to 6 microg/kg), cloxacillin (33 to 42 microg/kg), cefoperazone (73 to 82 microg/kg), cefalexin (160 to 202 microg/kg), gentamycin (355 to 382 microg/kg), streptomycin (3,063 to 3,593 microg/kg), tilmicosin (109 to 131 microg/kg), erythromycin (444 to 522 microg/kg), spyramicin (1,106 to 1,346 microg/kg), sulfadimethoxine (101 to 119 microg/kg), sulfathiazole (122 to 151 microg/kg), sulfamethazine (309 to 328 microg/kg), sulfanilamide (1,750 to 2,674 microg/kg), tetracycline (233 to 257 microg/kg), oxytetracycline (398 to 501 microg/kg), doxycycline (323 to 419 microg/kg), chlortetracycline (3,331 to 3,989 microg/kg), danofloxacin (4.7 to 5.5 mg/kg), enrofloxacin (41 to 46 mg/kg), and flumequin (63 to 71 mg/kg) were higher than the EU-MRL. Although the blue-yellow method showed improved sensitivity compared with other tests studied in ovine milk, the performance of screening methods for detecting antimicrobial agents in milk of this species should be improved.

  7. Conducting electrospun fibres with polyanionic grafts as highly selective, label-free, electrochemical biosensor with a low detection limit for non-Hodgkin lymphoma gene.

    Science.gov (United States)

    Kerr-Phillips, Thomas E; Aydemir, Nihan; Chan, Eddie Wai Chi; Barker, David; Malmström, Jenny; Plesse, Cedric; Travas-Sejdic, Jadranka

    2018-02-15

    A highly selective, label-free sensor for the non-Hodgkin lymphoma gene, with an aM detection limit, utilizing electrochemical impedance spectroscopy (EIS) is presented. The sensor consists of a conducting electrospun fibre mat, surface-grafted with poly(acrylic acid) (PAA) brushes and a conducting polymer sensing element with covalently attached oligonucleotide probes. The sensor was fabricated from electrospun NBR rubber, embedded with poly(3,4-ethylenedioxythiophene) (PEDOT), followed by grafting poly(acrylic acid) brushes and then electrochemically polymerizing a conducting polymer monomer with ssDNA probe sequence pre-attached. The resulting non-Hodgkin lymphoma gene sensor showed a detection limit of 1aM (1 × 10 -18 mol/L), more than 400 folds lower compared to a thin-film analogue. The sensor presented extraordinary selectivity, with only 1%, 2.7% and 4.6% of the signal recorded for the fully non-complimentary, T-A and G-C base mismatch oligonucleotide sequences, respectively. We suggest that such greatly enhanced selectivity is due to the presence of negatively charged carboxylic acid moieties from PAA grafts that electrostatically repel the non-complementary and mismatch DNA sequences, overcoming the non-specific binding. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. The solar-flare infrared continuum: observational techniques and upper limits

    International Nuclear Information System (INIS)

    Hudson, H.S.

    1975-01-01

    Exploratory observations at 20μ and 350 μ have determined detection thresholds for solar flares in these wavelengths. In the 20μ range solar atmospheric fluctuations (the 'temperature field') set the basic limits on flare detectability at approximately 5K; at 350μ the extinction in the Earth's atmosphere provides the basic limitation of approximately 30 K. These thresholds are low enough for the successful detection of several infrared-emitting components of large flares. Limited observing time and lack of solar activity have prevented observations of large flares up to the present, but the techniques promise to be extremely useful in the future. The upper limits obtained thus far, for subflares, indicate that the thickness of the Hα flare region does not exceed approximately 10 km. This result confirms the conclusion of Suemoto and Hiei (1959) regarding the small effective thickness of the Hα-emitting regions in solar flares. (Auth.)

  9. Diagnostic accuracy of the detection of bone change using panoramic TMJ projection. Comparative study with limited cone-beam CT

    International Nuclear Information System (INIS)

    Araki, Kazuyuki; Okano, Tomohiro; Kataoka, Ryuta; Honda, Kazuya; Endo, Atsushi; Kaneko, Norikazu; Funahashi, Itsuo

    2008-01-01

    Panoramic temporoman joint (TMJ) projection is one of the alternative methods of conventional radiography, such as transcranial projection, for diagnosing temporomandibular joint disorder. There have been a few reports describing the diagnostic ability of this method. We evaluated the diagnostic accuracy of detecting bone change with panoramic TMJ projection. Fifty TMJs in 25 patients were examined. All TMJs were examined by panoramic TMJ projection (Hyper XF) and limited cone-beam CT (3D Accuitomo FPD; 3DX). Two observers evaluated the presence of bone change in the TMJ region using panoramic TMJ projection. One other observer evaluated the limited cone-beam CT for the presence and the pattern of bone changes in the TMJ region as the gold standard. Panoramic TMJ findings were evaluated with regard to sensitivity, specificity, and accuracy. Sensitivity, specificity and accuracy of the panoramic TMJ projection were 0.86, 0.76, and 0.82, respectively. These results and those of previous reports on other radiographic methods for TMJ suggest that panoramic TMJ projection is a useful method of screening for bone change due to TMJ disorder. (author)

  10. Memory detection 2.0: The first web-based memory detection test

    NARCIS (Netherlands)

    Kleinberg, B.; Verschuere, B.

    2015-01-01

    There is accumulating evidence that reaction times (RTs) can be used to detect recognition of critical (e.g., crime) information. A limitation of this research base is its reliance upon small samples (average n = 24), and indications of publication bias. To advance RT-based memory detection, we

  11. Electrochemical Detection in Stacked Paper Networks.

    Science.gov (United States)

    Liu, Xiyuan; Lillehoj, Peter B

    2015-08-01

    Paper-based electrochemical biosensors are a promising technology that enables rapid, quantitative measurements on an inexpensive platform. However, the control of liquids in paper networks is generally limited to a single sample delivery step. Here, we propose a simple method to automate the loading and delivery of liquid samples to sensing electrodes on paper networks by stacking multiple layers of paper. Using these stacked paper devices (SPDs), we demonstrate a unique strategy to fully immerse planar electrodes by aqueous liquids via capillary flow. Amperometric measurements of xanthine oxidase revealed that electrochemical sensors on four-layer SPDs generated detection signals up to 75% higher compared with those on single-layer paper devices. Furthermore, measurements could be performed with minimal user involvement and completed within 30 min. Due to its simplicity, enhanced automation, and capability for quantitative measurements, stacked paper electrochemical biosensors can be useful tools for point-of-care testing in resource-limited settings. © 2015 Society for Laboratory Automation and Screening.

  12. Long range surface plasmon resonance with ultra-high penetration depth for self-referenced sensing and ultra-low detection limit using diverging beam approach

    Energy Technology Data Exchange (ETDEWEB)

    Isaacs, Sivan, E-mail: sivan.isaacs@gmail.com; Abdulhalim, Ibrahim [Department of Electro-Optical Engineering and TheIlse Katz Institute for Nanoscale Science and Technology, Ben Gurion University of the Negev, Beer Sheva 84105 (Israel); NEW CREATE Programme, School of Materials Science and Engineering, 1 CREATE Way, Research Wing, #02-06/08, Singapore 138602 (Singapore)

    2015-05-11

    Using an insulator-metal-insulator structure with dielectric having refractive index (RI) larger than the analyte, long range surface plasmon (SP) resonance exhibiting ultra-high penetration depth is demonstrated for sensing applications of large bioentities at wavelengths in the visible range. Based on the diverging beam approach in Kretschmann-Raether configuration, one of the SP resonances is shown to shift in response to changes in the analyte RI while the other is fixed; thus, it can be used as a built in reference. The combination of the high sensitivity, high penetration depth and self-reference using the diverging beam approach in which a dark line is detected of the high sensitivity, high penetration depth, self-reference, and the diverging beam approach in which a dark line is detected using large number of camera pixels with a smart algorithm for sub-pixel resolution, a sensor with ultra-low detection limit is demonstrated suitable for large bioentities.

  13. Methodology applied by the Petroleum, Natural Gas and Bio fuels National Agency for detection of cartels - their limits and perspectives; Metodology adotada pela Agencia Nacional do Petroleo, Gas Natural e Biocombustiveis para detectecao de carteis - seus limites e perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Pedra, Douglas Pereira; Sales, Orlando de Araujo Vilela; Baran, Patricia Huguenin; Paiva, Rodrigo Milao de [Agencia Nacional do Petroleo, Gas Natural e Biocombustiveis (ANP), Rio de Janeiro, RJ (Brazil). Regulacao de Petroleo, seus Derivados, Alcool Combustivel e Gas Natural; Bicalho, Lucia Maria de Oliveira Navegantes [Universidade Federal do Rio de Janeiro (PPE/COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Programa de Planejamento Energetico

    2010-07-01

    This paper presents the present methodology used by the Defense Competition Coordination of the Petroleum National Agency for detection of vestiges of cartels in the Brazilian fuel market, their limits, in view of the instruments presently at the disposal of the Agency and perspectives of modification from the eventual availability of new instruments.

  14. NSSEFF Designing New Higher Temperature Superconductors

    Science.gov (United States)

    2017-04-13

    AFRL-AFOSR-VA-TR-2017-0083 NSSEFF - DESIGINING NEW HIGHER TEMPERATURE SUPERCONDUCTORS Meigan Aronson THE RESEARCH FOUNDATION OF STATE UNIVERSITY OF...2015 4. TITLE AND SUBTITLE NSSEFF - DESIGINING NEW HIGHER TEMPERATURE SUPERCONDUCTORS 5a.  CONTRACT NUMBER 5b.  GRANT NUMBER FA9550-10-1-0191 5c...materials, identifying the most promising candidates. 15. SUBJECT TERMS TEMPERATURE, SUPERCONDUCTOR 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF

  15. Evaluation of a microbiological indicator test for antibiotic detection in ewe and goat milk.

    Science.gov (United States)

    Comunian, R; Paba, A; Dupré, I; Daga, E S; Scintu, M F

    2010-12-01

    Antibiotics are widely used for therapeutic and prophylactic purposes in dairy animals. The presence of residual antibiotics in milk could cause potentially serious problems in human health and have technological implication in the manufacturing of dairy products. The aim of this study was to evaluate Delvotest Accelerator (DSM Food Specialties, Delft, the Netherlands), a new system for a fully automated microbial test to detect antibiotic residues in ewe and goat milk. Forty-three samples of raw, whole, refrigerated bulk-tank milk samples (22 of ewe milk and 21 of goat milk) were analyzed during the whole lactation period. Four concentrations of 4 antibiotics were diluted in milk: penicillin G at 1, 2, 3, and 4 μg/L; sulfadiazine at 25, 50, 100, and 200 μg/L; tetracycline at 50, 100, 200, and 400 μg/L; and gentamicin at 25, 50, 100, and 200 μg/L. The detection limit of the Delvotest Accelerator was calculated as the range of antibiotic concentrations within which 95% of positive result lie. The range of detection limit of penicillin G and sulfadiazine was easily detected by Delvotest Accelerator at or below the European Union maximum residue limits, both for ewe and goat milk samples. In contrast, the system showed a lower ability to detect tetracycline and gentamicin both for ewe and goat milk samples. Very low percentages of false-positive outcomes were obtained. Lactation phase did not seem to be a crucial factor affecting the ability of the Delvotest Accelerator to detect spiked milk samples. A higher detection ability was observed for goat milk samples compared with ewe milk samples. A negative correlation between the percentage of positive milk samples detected and milk fat, protein, and lactose contents was observed for gentamicin only. Copyright © 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  16. Detection and identification of extra virgin olive oil adulteration by GC-MS combined with chemometrics.

    Science.gov (United States)

    Yang, Yang; Ferro, Miguel Duarte; Cavaco, Isabel; Liang, Yizeng

    2013-04-17

    In this study, an analytical method for the detection and identification of extra virgin olive oil adulteration with four types of oils (corn, peanut, rapeseed, and sunflower oils) was proposed. The variables under evaluation included 22 fatty acids and 6 other significant parameters (the ratio of linoleic/linolenic acid, oleic/linoleic acid, total saturated fatty acids (SFAs), polyunsaturated fatty acids (PUFAs), monounsaturated fatty acids (MUFAs), MUFAs/PUFAs). Univariate analyses followed by multivariate analyses were applied to the adulteration investigation. As a result, the univariate analyses demonstrated that higher contents of eicosanoic acid, docosanoic acid, tetracosanoic acid, and SFAs were the peculiarities of peanut adulteration and higher levels of linolenic acid, 11-eicosenoic acid, erucic acid, and nervonic acid the characteristics of rapeseed adulteration. Then, PLS-LDA made the detection of adulteration effective with a 1% detection limit and 90% prediction ability; a Monte Carlo tree identified the type of adulteration with 85% prediction ability.

  17. Detection and quantification limits: basic concepts, international harmonization, and outstanding ('low-level') issues

    International Nuclear Information System (INIS)

    Currie, L.A.

    2004-01-01

    A brief review is given of concepts, basic definitions, and terminology for metrological detection and quantification capabilities, representing harmonized recommendations and norms of the International Union of Pure and Applied Chemistry (IUPAC) and the International Organization for Standardization (ISO), respectively. Treatment of the (low-level) blank and variance function are discussed in some detail, together with special problems arising with detection decisions and the reporting of low-level data. Key references to the international documents follow, as well as specialized references addressing very low-level counting data, skewed environmental blank distributions, and multiple and multivariate detection decisions

  18. The limitations on organic detection in Mars-like soils by thermal volatilization-gas chromatography-MS and their implications for the Viking results.

    Science.gov (United States)

    Navarro-González, Rafael; Navarro, Karina F; de la Rosa, José; Iñiguez, Enrique; Molina, Paola; Miranda, Luis D; Morales, Pedro; Cienfuegos, Edith; Coll, Patrice; Raulin, François; Amils, Ricardo; McKay, Christopher P

    2006-10-31

    The failure of Viking Lander thermal volatilization (TV) (without or with thermal degradation)-gas chromatography (GC)-MS experiments to detect organics suggests chemical rather than biological interpretations for the reactivity of the martian soil. Here, we report that TV-GC-MS may be blind to low levels of organics on Mars. A comparison between TV-GC-MS and total organics has been conducted for a variety of Mars analog soils. In the Antarctic Dry Valleys and the Atacama and Libyan Deserts we find 10-90 mug of refractory or graphitic carbon per gram of soil, which would have been undetectable by the Viking TV-GC-MS. In iron-containing soils (jarosites from Rio Tinto and Panoche Valley) and the Mars simulant (palogonite), oxidation of the organic material to carbon dioxide (CO(2)) by iron oxides and/or their salts drastically attenuates the detection of organics. The release of 50-700 ppm of CO(2) by TV-GC-MS in the Viking analysis may indicate that an oxidation of organic material took place. Therefore, the martian surface could have several orders of magnitude more organics than the stated Viking detection limit. Because of the simplicity of sample handling, TV-GC-MS is still considered the standard method for organic detection on future Mars missions. We suggest that the design of future organic instruments for Mars should include other methods to be able to detect extinct and/or extant life.

  19. The limitations on organic detection in Mars-like soils by thermal volatilization–gas chromatography–MS and their implications for the Viking results

    Science.gov (United States)

    Navarro-González, Rafael; Navarro, Karina F.; de la Rosa, José; Iñiguez, Enrique; Molina, Paola; Miranda, Luis D.; Morales, Pedro; Cienfuegos, Edith; Coll, Patrice; Raulin, François; Amils, Ricardo; McKay, Christopher P.

    2006-01-01

    The failure of Viking Lander thermal volatilization (TV) (without or with thermal degradation)–gas chromatography (GC)–MS experiments to detect organics suggests chemical rather than biological interpretations for the reactivity of the martian soil. Here, we report that TV–GC–MS may be blind to low levels of organics on Mars. A comparison between TV–GC–MS and total organics has been conducted for a variety of Mars analog soils. In the Antarctic Dry Valleys and the Atacama and Libyan Deserts we find 10–90 μg of refractory or graphitic carbon per gram of soil, which would have been undetectable by the Viking TV–GC–MS. In iron-containing soils (jarosites from Rio Tinto and Panoche Valley) and the Mars simulant (palogonite), oxidation of the organic material to carbon dioxide (CO2) by iron oxides and/or their salts drastically attenuates the detection of organics. The release of 50–700 ppm of CO2 by TV–GC–MS in the Viking analysis may indicate that an oxidation of organic material took place. Therefore, the martian surface could have several orders of magnitude more organics than the stated Viking detection limit. Because of the simplicity of sample handling, TV–GC–MS is still considered the standard method for organic detection on future Mars missions. We suggest that the design of future organic instruments for Mars should include other methods to be able to detect extinct and/or extant life. PMID:17060639

  20. Improvement in limit of detection in particle induced X-ray emission by means of rise time and pulse shape discrimination

    Energy Technology Data Exchange (ETDEWEB)

    Papp, Tibor E-mail: tibpapp@netscape.nettibpapp@yahoo.ca; Lakatos, Tamas; Nejedly, Zdenek; Campbell, John L

    2002-04-01

    A digital signal processor, based upon high-rate sampling of the preamplifier output, and equipped with rise time and pulse shape discrimination, has been tested in three situations. This processor provided significant improvement of particle induced X-ray emission and X-ray fluorescence detection limits over the state of the art analog processors, depending on the energy and intensity distribution of the X-ray spectra. Additionally it had a superior performance when measurements were performed in an environment of large electronic noise and in large nuclear background environment. It has also improved the reduction of several artifacts in X-ray spectra.

  1. Nondestructive materials evaluation and imaging by higher harmonics

    International Nuclear Information System (INIS)

    Kawashima, Koichiro

    2012-01-01

    Nondestructive detection of material anormalities, degradation and tight cracks, in which the acoustic impedance mismatch is low, is rather difficult by conventional ultrasonic testing. A novel nonlinear ultrasonic technique, in particular, higher harmonic technique, utilizes the waveform distortion, which results from the interaction between anormalities and large amplitude tone-burst waves. This technique is not affected by acoustic impedance mismatch, therefore, it has possibility to detect such anormalities, degradation and tight cracks. A novel higher harmonic imaging technique is proposed and applied to detect and visualize local plastic deformation of SUS 304 plates, plastic zone in front of crack tip, weld bond contour of carbon steel, small inclusions in ODS steel fuel tubes, pitting damage of SUS 316 plates in mercury, shallow fatigue cracks of SUS 316 plates introduced by thermal fatigue, and inter-granular stress corrosion cracking, IGSCC, in welded plates simulated safe-ends for bonding dissimilar metals. (author)

  2. Gas chromatography with flame photometric detection of 31 organophosphorus pesticide residues in Alpinia oxyphylla dried fruits.

    Science.gov (United States)

    Zhao, Xiangsheng; Kong, Weijun; Wei, Jianhe; Yang, Meihua

    2014-11-01

    A simple, rapid and effective gas chromatography-flame photometric detection method was established for simultaneous multi-component determination of 31 organophosphorus pesticides (OPPs) residues in Alpinia oxyphylla, which is widely consumed as a traditional medicine and food in China. Sample preparation was completed in a single step without any clean-up procedure. All pesticides expressed good linear relationships between 0.004 and 1.0 μg/mL with correlation coefficients higher than 0.9973. The method gave satisfactory recoveries for most pesticides. The limits of detection varied from 1 to 10 ng/mL, and the limits of quantification (LOQs) were between 4 and 30 ng/mL. The proposed method was successfully applied to 55 commercial samples purchased from five different areas. Five pesticide residues were detected in four (7.27%) samples. The positive samples were confirmed by gas chromatography with tandem mass spectrometry (GC-MS/MS). Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Detecting gravitational waves from precessing binaries of spinning compact objects: Adiabatic limit

    International Nuclear Information System (INIS)

    Buonanno, Alessandra; Chen Yanbei; Vallisneri, Michele

    2003-01-01

    Black-hole (BH) binaries with single-BH masses m=(5-20)M · , moving on quasicircular orbits, are among the most promising sources for first-generation ground-based gravitational-wave (GW) detectors. Until now, the development of data-analysis techniques to detect GWs from these sources has been focused mostly on nonspinning BHs. The data-analysis problem for the spinning case is complicated by the necessity to model the precession-induced modulations of the GW signal, and by the large number of parameters needed to characterize the system, including the initial directions of the spins, and the position and orientation of the binary with respect to the GW detector. In this paper we consider binaries of maximally spinning BHs, and we work in the adiabatic-inspiral regime to build families of modulated detection templates that (i) are functions of very few physical and phenomenological parameters, (ii) model remarkably well the dynamical and precessional effects on the GW signal, with fitting factors on average > or approx. 0.97, (iii) but, however, might require increasing the detection thresholds, offsetting at least partially the gains in the fitting factors. Our detection-template families are quite promising also for the case of neutron-star-black-hole binaries, with fitting factors on average ≅0.93. For these binaries we also suggest (but do not test) a further template family, which would produce essentially exact waveforms written directly in terms of the physical spin parameters

  4. Detection Limits Of The 125I Air Sampler ''RIS125''

    International Nuclear Information System (INIS)

    Belaish, I.; Levinson, S.; German, U.; Kravchik, T.

    1999-01-01

    A system for 125 I monitoring in air (RIS-125) was designed and manufactured at NRCN. The main features of the system are described elsewhere. The system can monitor 125 I air contamination in gaseous and aerosol forms. An air monitoring system should have a fast response and the lowest available Minimum Detectable Activity (MDA). The present work presents the characteristic MDA values of the system

  5. Optimization and characterization of condensation nucleation light scattering detection coupled with supercritical fluid chromatography

    Science.gov (United States)

    Yang, Shaoping

    This dissertation is an investigation of two aspects of coupling condensation nucleation light scattering detection (CNLSD) with supercritical fluid chromatography (SFC). In the first part, it was demonstrated that CNLSD was compatible with packed column SFC using either pure CO2 or organic solvent modified CO2 as mobile phases. Factors which were expected to affect the interface between SFC and CNLSD were optimized for the detector to reach low detection limits. With SFC using pure CO2 as mobile phase, the detection limit of CNLSD with SFC was observed to be at low nanogram levels, which was at the same level of flame ionization detection (FID) coupled with SFC. For SFC using modified CO2 as mobile phase, detection limits at the picogram level were observed for CNLSD at optimal conditions, which were at least ten times lower than those reached by evaporative light scattering detection. In the second part, particle size distributions of aerosols produced from rapid expansion of supercritical solutions were measured with a scanning mobility particle sizer. The effect of the factors, which were investigated in the first part for their effects on signal intensities and signal to noise ratios (S/N), on particle size distributions (PSDs) of both analyte and background were investigated. Whenever possible, both particle sizes and particle number obtained from PSDs were used to explain the optimization results. In general, PSD data support the observations made in the first part. The detection limits of CNLSD obtained were much higher than predicted. PSDs did not provide direct explanation of this problem. The amount of analyte deposited in the transport tubing, evaporated to gas phase, and condensed to form particles was determined experimentally. Almost no analyte was found in the gas phase. Less than 3% was found in the particle forms. The vast majority of analyte was lost in the transport tubing, especially in the short distance after supercritical fluid expansion. A

  6. Calculating exclusion limits for weakly interacting massive particle direct detection experiments without background subtraction

    International Nuclear Information System (INIS)

    Green, Anne M.

    2002-01-01

    Competitive limits on the weakly interacting massive particle (WIMP) spin-independent scattering cross section are currently being produced by 76 Ge detectors originally designed to search for neutrinoless double beta decay, such as the Heidelberg-Moscow and IGEX experiments. In the absence of background subtraction, limits on the WIMP interaction cross section are set by calculating the upper confidence limit on the theoretical event rate, given the observed event rate. The standard analysis technique involves calculating the 90% upper confidence limit on the number of events in each bin, and excluding any set of parameters (WIMP mass and cross section) which produces a theoretical event rate for any bin which exceeds the 90% upper confidence limit on the event rate for that bin. We show that, if there is more than one energy bin, this produces exclusion limits that are actually at a lower degree of confidence than 90%, and are hence erroneously tight. We formulate criteria which produce true 90% confidence exclusion limits in these circumstances, including calculating the individual bin confidence limit for which the overall probability that no bins exceed this confidence limit is 90% and calculating the 90% minimum confidence limit on the number of bins which exceed their individual bin 90% confidence limits. We then compare the limits on the WIMP cross section produced by these criteria with those found using the standard technique, using data from the Heidelberg-Moscow and IGEX experiments

  7. Digital Holographic Microscopy, a Method for Detection of Microorganisms in Plume Samples from Enceladus and Other Icy Worlds.

    Science.gov (United States)

    Bedrossian, Manuel; Lindensmith, Chris; Nadeau, Jay L

    2017-09-01

    Detection of extant microbial life on Earth and elsewhere in the Solar System requires the ability to identify and enumerate micrometer-scale, essentially featureless cells. On Earth, bacteria are usually enumerated by culture plating or epifluorescence microscopy. Culture plates require long incubation times and can only count culturable strains, and epifluorescence microscopy requires extensive staining and concentration of the sample and instrumentation that is not readily miniaturized for space. Digital holographic microscopy (DHM) represents an alternative technique with no moving parts and higher throughput than traditional microscopy, making it potentially useful in space for detection of extant microorganisms provided that sufficient numbers of cells can be collected. Because sample collection is expected to be the limiting factor for space missions, especially to outer planets, it is important to quantify the limits of detection of any proposed technique for extant life detection. Here we use both laboratory and field samples to measure the limits of detection of an off-axis digital holographic microscope (DHM). A statistical model is used to estimate any instrument's probability of detection at various bacterial concentrations based on the optical performance characteristics of the instrument, as well as estimate the confidence interval of detection. This statistical model agrees well with the limit of detection of 10 3 cells/mL that was found experimentally with laboratory samples. In environmental samples, active cells were immediately evident at concentrations of 10 4 cells/mL. Published estimates of cell densities for Enceladus plumes yield up to 10 4 cells/mL, which are well within the off-axis DHM's limits of detection to confidence intervals greater than or equal to 95%, assuming sufficient sample volumes can be collected. The quantitative phase imaging provided by DHM allowed minerals to be distinguished from cells. Off-axis DHM's ability for

  8. Advantages and Limitations of Androgen Receptor-Based Methods for Detecting Anabolic Androgenic Steroid Abuse as Performance Enhancing Drugs

    Science.gov (United States)

    Bailey, Kathy; Yazdi, Tahmineh; Masharani, Umesh; Tyrrell, Blake; Butch, Anthony; Schaufele, Fred

    2016-01-01

    Testosterone (T) and related androgens are performance enhancing drugs (PEDs) abused by some athletes to gain competitive advantage. To monitor unauthorized androgen abuse, doping control programs use mass spectrometry (MS) to detect androgens, synthetic anabolic-androgenic steroids (AASs) and their metabolites in an athlete’s urine. AASs of unknown composition will not be detected by these procedures. Since AASs achieve their anabolic effects by activating the Androgen Receptor (AR), cell-based bioassays that measure the effect of a urine sample on AR activity are under investigation as complementary, pan-androgen detection methods. We evaluated an AR BioAssay as a monitor for androgen activity in urine pre-treated with glucuronidase, which releases T from the inactive T-glucuronide that predominates in urine. AR BioAssay activity levels were expressed as ‘T-equivalent’ concentrations by comparison to a T dose response curve. The T-equivalent concentrations of androgens in the urine of hypogonadal participants supplemented with T (in whom all androgenic activity should arise from T) were quantitatively identical to the T measurements conducted by MS at the UCLA Olympic Analytical Laboratory (0.96 ± 0.22). All 17 AASs studied were active in the AR BioAssay; other steroids were inactive. 12 metabolites of 10 commonly abused AASs, which are used for MS monitoring of AAS doping because of their prolonged presence in urine, had reduced or no AR BioAssay activity. Thus, the AR BioAssay can accurately and inexpensively monitor T, but its ability to monitor urinary AASs will be limited to a period immediately following doping in which the active AASs remain intact. PMID:26998755

  9. Advantages and Limitations of Androgen Receptor-Based Methods for Detecting Anabolic Androgenic Steroid Abuse as Performance Enhancing Drugs.

    Science.gov (United States)

    Bailey, Kathy; Yazdi, Tahmineh; Masharani, Umesh; Tyrrell, Blake; Butch, Anthony; Schaufele, Fred

    2016-01-01

    Testosterone (T) and related androgens are performance enhancing drugs (PEDs) abused by some athletes to gain competitive advantage. To monitor unauthorized androgen abuse, doping control programs use mass spectrometry (MS) to detect androgens, synthetic anabolic-androgenic steroids (AASs) and their metabolites in an athlete's urine. AASs of unknown composition will not be detected by these procedures. Since AASs achieve their anabolic effects by activating the Androgen Receptor (AR), cell-based bioassays that measure the effect of a urine sample on AR activity are under investigation as complementary, pan-androgen detection methods. We evaluated an AR BioAssay as a monitor for androgen activity in urine pre-treated with glucuronidase, which releases T from the inactive T-glucuronide that predominates in urine. AR BioAssay activity levels were expressed as 'T-equivalent' concentrations by comparison to a T dose response curve. The T-equivalent concentrations of androgens in the urine of hypogonadal participants supplemented with T (in whom all androgenic activity should arise from T) were quantitatively identical to the T measurements conducted by MS at the UCLA Olympic Analytical Laboratory (0.96 ± 0.22). All 17 AASs studied were active in the AR BioAssay; other steroids were inactive. 12 metabolites of 10 commonly abused AASs, which are used for MS monitoring of AAS doping because of their prolonged presence in urine, had reduced or no AR BioAssay activity. Thus, the AR BioAssay can accurately and inexpensively monitor T, but its ability to monitor urinary AASs will be limited to a period immediately following doping in which the active AASs remain intact.

  10. Biosensor technology for the detection of illegal drugs II: antibody development and detection techniques

    Science.gov (United States)

    Hilpert, Reinhold; Bauer, Christian; Binder, Florian; Grol, Michael; Hallermayer, Klaus; Josel, Hans-Peter; Klein, Christian; Maier, Josef; Makower, Alexander; Oberpriller, Helmut; Ritter, Josef

    1994-10-01

    In a joint project of Deutsche Aerospace, Boehringer Mannheim and the University of Potsdam portable devices for the detection of illegal drugs, based on biosensor technology, are being developed. The concept enrichment of the drug from the gas phase and detection by immunological means. This publication covers the development of specific antibodies and various detection procedures. Antibodies with a high affinity for cocaine have been developed with the aid of specially synthesized immunogens. A competitive detection procedure with biosensors based on optical grating couplers and applying particulate labels has been established, showing a lower detection limit of 10-10 mol/l for cocaine. Additionally, a combination of a displacement-immunoreactor and an enzymatically amplified electrode was investigated, which at present still suffers from insufficient sensitivity of the immunoreactor. An alternative, fleece-matrix based test procedure, where enrichment and detection steps are integrated in a single unit, is promising in terms of simplicity and sensitivity. A simple swab-test for the detection of cocaine at surfaces has been developed, which has a lower detection limit of about 10 ng and which can be performed within one minute.

  11. Enhanced dopamine detection sensitivity by PEDOT/graphene oxide coating on in vivo carbon fiber electrodes.

    Science.gov (United States)

    Taylor, I Mitch; Robbins, Elaine M; Catt, Kasey A; Cody, Patrick A; Happe, Cassandra L; Cui, Xinyan Tracy

    2017-03-15

    Dopamine (DA) is a monoamine neurotransmitter responsible for regulating a variety of vital life functions. In vivo detection of DA poses a challenge due to the low concentration and high speed of physiological signaling. Fast scan cyclic voltammetry at carbon fiber microelectrodes (CFEs) is an effective method to monitor real-time in vivo DA signaling, however the sensitivity is somewhat limited. Electrodeposition of poly(3,4-ethylene dioxythiophene) (PEDOT)/graphene oxide (GO) onto the CFE surface is shown to increase the sensitivity and lower the limit of detection for DA compared to bare CFEs. Thicker PEDOT/GO coatings demonstrate higher sensitivities for DA, but display the negative drawback of slow adsorption and electron transfer kinetics. The moderate thickness resulting from 25 s electrodeposition of PEDOT/GO produces the optimal electrode, exhibiting an 880% increase in sensitivity, a 50% decrease in limit of detection and minimally altered electrode kinetics. PEDOT/GO coated electrodes rapidly and robustly detect DA, both in solution and in the rat dorsal striatum. This increase in DA sensitivity is likely due to increasing the electrode surface area with a PEDOT/GO coating and improved adsorption of DA's oxidation product (DA-o-quinone). Increasing DA sensitivity without compromising electrode kinetics is expected to significantly improve our understanding of the DA function in vivo. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. First Limit on the Direct Detection of Lightly Ionizing Particles for Electric Charge as Low as e /1000 with the Majorana Demonstrator

    Science.gov (United States)

    Alvis, S. I.; Arnquist, I. J.; Avignone, F. T.; Barabash, A. S.; Barton, C. J.; Bertrand, F. E.; Brudanin, V.; Busch, M.; Buuck, M.; Caldwell, T. S.; Chan, Y.-D.; Christofferson, C. D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Dunagan, C.; Efremenko, Yu.; Ejiri, H.; Elliott, S. R.; Gilliss, T.; Giovanetti, G. K.; Green, M. P.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Haufe, C. R.; Hehn, L.; Henning, R.; Hoppe, E. W.; Howe, M. A.; Konovalov, S. I.; Kouzes, R. T.; Lopez, A. M.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Myslik, J.; O'Shaughnessy, C.; Othman, G.; Pettus, W.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Reine, A. L.; Rielage, K.; Robertson, R. G. H.; Ruof, N. W.; Shanks, B.; Shirchenko, M.; Suriano, A. M.; Tedeschi, D.; Varner, R. L.; Vasilyev, S.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C.-H.; Yumatov, V.; Zhitnikov, I.; Zhu, B. X.; Majorana Collaboration

    2018-05-01

    The Majorana Demonstrator is an ultralow-background experiment searching for neutrinoless double-beta decay in 76Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. Free, relativistic, lightly ionizing particles with an electrical charge less than e are forbidden by the standard model but predicted by some of its extensions. If such particles exist, they might be detected in the Majorana Demonstrator by searching for multiple-detector events with individual-detector energy depositions down to 1 keV. This search is background-free, and no candidate events have been found in 285 days of data taking. New direct-detection limits are set for the flux of lightly ionizing particles for charges as low as e /1000 .

  13. Statistical methods for assays with limits of detection: Serum bile acid as a differentiator between patients with normal colons, adenomas, and colorectal cancer

    Directory of Open Access Journals (Sweden)

    Bonnie LaFleur

    2011-01-01

    Full Text Available In analytic chemistry a detection limit (DL is the lowest measurable amount of an analyte that can be distinguished from a blank; many biomedical measurement technologies exhibit this property. From a statistical perspective, these data present inferential challenges because instead of precise measures, one only has information that the value is somewhere between 0 and the DL (below detection limit, BDL. Substitution of BDL values, with 0 or the DL can lead to biased parameter estimates and a loss of statistical power. Statistical methods that make adjustments when dealing with these types of data, often called left-censored data, are available in many commercial statistical packages. Despite this availability, the use of these methods is still not widespread in biomedical literature. We have reviewed the statistical approaches of dealing with BDL values, and used simulations to examine the performance of the commonly used substitution methods and the most widely available statistical methods. We have illustrated these methods using a study undertaken at the Vanderbilt-Ingram Cancer Center, to examine the serum bile acid levels in patients with colorectal cancer and adenoma. We have found that the modern methods for BDL values identify disease-related differences that are often missed, with statistically naive approaches.

  14. Intelligent Flamefinder Detection and Alert System (IFDAS), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Current hydrogen flame detection systems exhibit shortcomings ranging from limited detection range, to localization inaccuracy, limited sensitivity, false alarms,...

  15. SERS activity with tenfold detection limit optimization on a type of nanoporous AAO-based complex multilayer substrate

    Science.gov (United States)

    Sui, Chaofan; Wang, Kaige; Wang, Shuang; Ren, Junying; Bai, Xiaohong; Bai, Jintao

    2016-03-01

    Most of SERS applications are constricted by heterogeneous hotspots and aggregates of nanostructure, which result in low sensitivity and poor reproducibility of characteristic signals. This work intends to introduce SERS properties of a type of SERS-active substrate, Au-CuCl2-AAO, which is innovatively developed on a porous anodic alumina oxide (AAO) template. Spectral measuring results of Rhodamine 6G (R6G) on this substrate optimized by controlling morphology and gold thickness showed that enhancement factor (2.30 × 107) and detection limit (10-10 M) were both improved and represented better performance than its template AAO. Homogenous hot spots across the region of interest were achieved by scanning SERS intensity distribution for the band at 1505 cm-1 in 5 × 5 μm2 area. Furthermore, the promising SERS activity of the flower-patterned substrate was theoretically explained through simulation of the electromagnetic field distribution. In addition, this SERS substrate is proposed for applications within the field of chemical and biochemical analyses.Most of SERS applications are constricted by heterogeneous hotspots and aggregates of nanostructure, which result in low sensitivity and poor reproducibility of characteristic signals. This work intends to introduce SERS properties of a type of SERS-active substrate, Au-CuCl2-AAO, which is innovatively developed on a porous anodic alumina oxide (AAO) template. Spectral measuring results of Rhodamine 6G (R6G) on this substrate optimized by controlling morphology and gold thickness showed that enhancement factor (2.30 × 107) and detection limit (10-10 M) were both improved and represented better performance than its template AAO. Homogenous hot spots across the region of interest were achieved by scanning SERS intensity distribution for the band at 1505 cm-1 in 5 × 5 μm2 area. Furthermore, the promising SERS activity of the flower-patterned substrate was theoretically explained through simulation of the

  16. A course of higher mathematics

    CERN Document Server

    Smirnov, Vladimir Ivanovich; Lohwater, A J

    1964-01-01

    A Course of Higher Mathematics, I: Elementary Calculus is a five-volume course of higher mathematics used by mathematicians, physicists, and engineers in the U.S.S.R. This volume deals with calculus and principles of mathematical analysis including topics on functions of single and multiple variables. The functional relationships, theory of limits, and the concept of differentiation, whether as theories and applications, are discussed. This book also examines the applications of differential calculus to geometry. For example, the equations to determine the differential of arc or the parameter

  17. Assessing Cyberbullying in Higher Education

    Science.gov (United States)

    Kamali, Ali

    2015-01-01

    This project aims to expose information educators to various aspects of cyberbullying for the purpose of policy development in an environment of higher education. The preponderance of nation-wide research on cyberbullying is concentrated on adolescents; such efforts in college campuses are limited to individual endeavors. Cyberbullying research on…

  18. Novel Voltage limiting concept for avalance breakdown protection

    NARCIS (Netherlands)

    Ruijs, L.C.H.; Bezooijen, van A.; Mahmoudi, R.; Roermund, van A.H.M.

    2006-01-01

    Destructive over-voltage breakdown of cellular phone power transistors is prevented by using a new voltage-limiting concept. The output voltage is detected by an avalanche-based detector, and limited by decreasing the output power when needed. The voltage detector contains a low voltage bipolar NPN

  19. Fiscal Stress: Worldwide Trends in Higher Education Finance

    NARCIS (Netherlands)

    Vossensteyn, Johan J.

    2004-01-01

    While higher education is regarded of high priority in boosting economic development, public budgets to sustain expansion of higher education systems remain limited around the globe. In practice, this situation of fiscal stress creates an impetus for governments to develop various strategies to meet

  20. ICG-assisted blood vessel detection during stereotactic neurosurgery: simulation study on excitation power limitations due to thermal effects in human brain tissue.

    Science.gov (United States)

    Rühm, Adrian; Göbel, Werner; Sroka, Ronald; Stepp, Herbert

    2014-09-01

    Intraoperative blood vessel detection based on intraluminal indocyanin-green (ICG) would allow to minimize the risk of blood vessel perforation during stereotactic brain tumor biopsy. For a fiber-based approach compatible with clinical conditions, the maximum tolerable excitation light power was derived from simulations of the thermal heat load on the tissue. Using the simulation software LITCIT, the temperature distribution in human brain tissue was calculated as a function of time for realistic single-fiber probes (0.72mm active diameter, numerical aperture 0.35, optional focusing to 0.29mm diameter) and for the optimum ICG excitation wavelength of 785nm. The asymptotic maximum temperature in the simulated tissue region was derived for different radiant fluxes at the distal fiber end. Worst case values were assumed for all other parameters. In addition to homogeneous (normal and tumor) brain tissue with homogeneous blood perfusion, models with localized extra blood vessels incorporated ahead of the distal fiber end were investigated. If one demands that destruction of normal brain tissue must be excluded by limiting the tissue heating to 42°C, then the radiant flux at the distal fiber end must be limited to 33mW with and 43mW without focusing. When considering extra blood vessels of 0.1mm diameter incorporated into homogeneously perfused brain tissue, the tolerable radiant flux is reduced to 22mW with and 32mW without focusing. The threshold value according to legal laser safety regulations for human skin tissue is 28.5mW. For the envisaged modality of blood vessel detection, light power limits for an application-relevant fiber configuration were determined and found to be roughly consistent with present legal regulations for skin tissue. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Limited communication capacity unveils strategies for human interaction

    Science.gov (United States)

    Miritello, Giovanna; Lara, Rubén; Cebrian, Manuel; Moro, Esteban

    2013-06-01

    Connectivity is the key process that characterizes the structural and functional properties of social networks. However, the bursty activity of dyadic interactions may hinder the discrimination of inactive ties from large interevent times in active ones. We develop a principled method to detect tie de-activation and apply it to a large longitudinal, cross-sectional communication dataset (~19 months, ~20 million people). Contrary to the perception of ever-growing connectivity, we observe that individuals exhibit a finite communication capacity, which limits the number of ties they can maintain active in time. On average men display higher capacity than women, and this capacity decreases for both genders over their lifespan. Separating communication capacity from activity reveals a diverse range of tie activation strategies, from stable to exploratory. This allows us to draw novel relationships between individual strategies for human interaction and the evolution of social networks at global scale.

  2. A label-free aptamer-fluorophore assembly for rapid and specific detection of cocaine in biofluids.

    Science.gov (United States)

    Roncancio, Daniel; Yu, Haixiang; Xu, Xiaowen; Wu, Shuo; Liu, Ran; Debord, Joshua; Lou, Xinhui; Xiao, Yi

    2014-11-18

    We report a rapid and specific aptamer-based method for one-step cocaine detection with minimal reagent requirements. The feasibility of aptamer-based detection has been demonstrated with sensors that operate via target-induced conformational change mechanisms, but these have generally exhibited limited target sensitivity. We have discovered that the cocaine-binding aptamer MNS-4.1 can also bind the fluorescent molecule 2-amino-5,6,7-trimethyl-1,8-naphthyridine (ATMND) and thereby quench its fluorescence. We subsequently introduced sequence changes into MNS-4.1 to engineer a new cocaine-binding aptamer (38-GC) that exhibits higher affinity to both ligands, with reduced background signal and increased signal gain. Using this aptamer, we have developed a new sensor platform that relies on the cocaine-mediated displacement of ATMND from 38-GC as a result of competitive binding. We demonstrate that our sensor can detect cocaine within seconds at concentrations as low as 200 nM, which is 50-fold lower than existing assays based on target-induced conformational change. More importantly, our assay achieves successful cocaine detection in body fluids, with a limit of detection of 10.4, 18.4, and 36 μM in undiluted saliva, urine, and serum samples, respectively.

  3. Limits and signatures of relativistic spaceflight

    Science.gov (United States)

    Yurtsever, Ulvi; Wilkinson, Steven

    2018-01-01

    While special relativity imposes an absolute speed limit at the speed of light, our Universe is not empty Minkowski spacetime. The constituents that fill the interstellar/intergalactic vacuum, including the cosmic microwave background photons, impose a lower speed limit on any object travelling at relativistic velocities. Scattering of cosmic microwave photons from an ultra-relativistic object may create radiation with a characteristic signature allowing the detection of such objects at large distances.

  4. A real-time PCR assay for the detection of atypical strains of Chlamydiaceae from pigeons.

    Directory of Open Access Journals (Sweden)

    Aleksandar Zocevic

    Full Text Available Recent evidence of the occurrence of atypical Chlamydiaceae strains in pigeons, different from the established Chlamydiaceae, requires the development of a specific and rapid detection tool to investigate their prevalence and significance. Here is described a new real-time PCR assay that allows specific detection of atypical Chlamydiaceae from pigeons. The assay has been used to assess the dissemination of these strains in field samples collected from Parisian pigeon populations in 2009. The results suggest a limited dissemination compared to the usually higher prevalence of Chlamydia psittaci that is the main species associated with avian chlamydiosis.

  5. Evaluation of a manual DNA extraction protocol and an isothermal amplification assay for detecting HIV-1 DNA from dried blood spots for use in resource-limited settings.

    Science.gov (United States)

    Jordan, Jeanne A; Ibe, Christine O; Moore, Miranda S; Host, Christel; Simon, Gary L

    2012-05-01

    In resource-limited settings (RLS) dried blood spots (DBS) are collected on infants and transported through provincial laboratories to a central facility where HIV-1 DNA PCR testing is performed using specialized equipment. Implementing a simpler approach not requiring such equipment or skilled personnel could allow the more numerous provincial laboratories to offer testing, improving turn-around-time to identify and treat infected infants sooner. Assess performances of a manual DNA extraction method and helicase-dependent amplification (HDA) assay for detecting HIV-1 DNA from DBS. 60 HIV-1 infected adults were enrolled, blood samples taken and DBS made. DBS extracts were assessed for DNA concentration and beta globin amplification using PCR and melt-curve analysis. These same extracts were then tested for HIV-1 DNA using HDA and compared to results generated by PCR and pyrosequencing. Finally, HDA limit of detection (LOD) studies were performed using DBS extracts prepared with known numbers of 8E5 cells. The manual extraction protocol consistently yielded high concentrations of amplifiable DNA from DBS. LOD assessment demonstrated HDA detected ∼470 copies/ml of HIV-1 DNA extracts in 4/4 replicates. No statistical difference was found using the McNemar's test when comparing HDA to PCR for detecting HIV-1 DNA from DBS. Using just a magnet, heat block and pipettes, the manual extraction protocol and HDA assay detected HIV-1 DNA from DBS at levels that would be useful for early infant diagnosis. Next steps will include assessing HDA for non-B HIV-1 subtypes recognition and comparison to Roche HIV-1 DNA v1.5 PCR assay. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. ZEPLIN-II limits on WIMP-nucelon interactions

    International Nuclear Information System (INIS)

    Alner, G. J.; Bungau, C.; Camanzi, B.; Durkin, T.; Edwards, B.; Lewin, J. D.; Luescher, R.; Preece, R. M.; Smith, N. J. T.; Smith, P. F.; Sumner, T. J.; Thorne, C.; Araujo, H. M.; Bewick, A.; Davidge, D.; Dawson, J.; Howard, A. S.; Jones, W. G.; Joshi, M.; Lebedenko, V. N.

    2009-01-01

    ZEPLIN II is a two-phase xenon detector designed to detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs). Following the first 31-day underground run in Boulby Mine, UK, the collaboration published dark matter limits in January 2007; the first such limits using two-phase xenon technology. We outline the key detector design, performance and results here.

  7. Use of an Electronic Tongue to Detect Geosmin in Distilled Water

    Science.gov (United States)

    Braga, Guilherme S.; Paterno, Leonardo G.; Fonseca, Fernando J.

    2011-11-01

    An electronic tongue (ET) system consisting of conducting polymer sensors was employed to detect geosmin (GSM) in distilled water. GSM is a tainting compound and known to cause undesirable tastes and odors in water and aquaculture farming. Diluted solutions of GSM were prepared in distilled water at different concentrations. The electrical response (capacitance) of the sensors was analyzed using principal analysis component (PCA). The data obtained were separated into different clusters indicating a good sensibility of the ET system to this compound in distilled water. The ET showed signal saturation for concentrations higher than 300 ng.L-1. So far, the detection limit of our system is 25 ng.L-1. Nevertheless, close grouping between repeated tests indicated that the ET system response is reproducible.

  8. Limits to magnetic resonance microscopy

    International Nuclear Information System (INIS)

    Glover, Paul; Mansfield, Peter

    2002-01-01

    The last quarter of the twentieth century saw the development of magnetic resonance imaging (MRI) grow from a laboratory demonstration to a multi-billion dollar worldwide industry. There is a clinical body scanner in almost every hospital of the developed nations. The field of magnetic resonance microscopy (MRM), after mostly being abandoned by researchers in the first decade of MRI, has become an established branch of the science. This paper reviews the development of MRM over the last decade with an emphasis on the current state of the art. The fundamental principles of imaging and signal detection are examined to determine the physical principles which limit the available resolution. The limits are discussed with reference to liquid, solid and gas phase microscopy. In each area, the novel approaches employed by researchers to push back the limits of resolution are discussed. Although the limits to resolution are well known, the developments and applications of MRM have not reached their limit. (author)

  9. Risk stratification and detection of new colorectal neoplasms after colorectal cancer screening with faecal occult blood test

    DEFF Research Database (Denmark)

    Bjerrum, Andreas; Milter, Maya Christel; Andersen, Ole

    2015-01-01

    BACKGROUND: Limited data exist on adenoma surveillance as recommended in the European guidelines for quality assurance in colorectal cancer (CRC) screening and diagnosis after faecal occult blood test (FOBT) screening. OBJECTIVE: To assess the European guidelines for adenoma surveillance after CRC...... of CRC was higher in risk group C than A (RR 5.20, 95% confidence interval: 0.63-42.58), but not statistically significant. In risk group C, half of new advanced adenomas were detected within the first year and four of nine CRC were detected within 3 years. CONCLUSION: Risk stratification of adenoma...

  10. DETERMINATION OF LIMIT DETECTION OF THE ELEMENTS N, P, K, Si, Al, Fe, Cu, Cd, WITH FAST NEUTRON ACTIVATION USING NEUTRON GENERATOR

    OpenAIRE

    Sunardi, Sunardi; Muryono, Muryono

    2010-01-01

    Determination of limit detection of the elements N, P, K, Si, Al, Fe, Cu, Cd, with fast neutron activation using neutron generator has been done.  Samples prepared from SRM 2704, N, P, K elements from MERCK, Cu, Cd, Al from activation foil made in San Carlos, weighted and packed for certain weight then iradiated during 30 minutes with 14 MeV fast neutron using the neutron generator and then counted with gamma spectrometry (accuspec).  At this research condition of neutron generator was set at...

  11. South African Journal of Higher Education - Vol 16, No 1 (2002)

    African Journals Online (AJOL)

    Guest Editorial: Globalisation and higher education restructuring in South Africa: ... South African legislation on limiting private and foreign higher education: ... Globalising and internationalising the higher education sector: challenges and ...

  12. Limit of detection and threshold for positivity of the Centers for Disease Control and Prevention assay for factor VIII inhibitors.

    Science.gov (United States)

    Miller, C H; Boylan, B; Shapiro, A D; Lentz, S R; Wicklund, B M

    2017-10-01

    Essentials Immunologic methods detect factor VIII (FVIII) antibodies in some inhibitor-negative specimens. Specimens were tested by modified Nijmegen-Bethesda assay (NBA) and fluorescence immunoassay. The NBA with preanalytical heat inactivation detects FVIII inhibitors down to 0.2 NBU. IgG 4 frequency validates the established threshold for positivity of ≥ 0.5 NBU for this NBA. Background The Bethesda assay for measurement of factor VIII inhibitors called for quantification of positive inhibitors by using dilutions producing 25-75% residual activity (RA), corresponding to 0.4-2.0 Bethesda units, with the use of 'more sensitive methods' for samples with RA closer to 100% being recommended. The Nijmegen modification (Nijmegen-Bethesda assay [NBA]) changed the reagents used but not these calculations. Some specimens negative by the NBA have been shown to have FVIII antibodies detectable with sensitive immunologic methods. Objective To examine the performance at very low inhibitor titers of the Centers for Disease Control and Prevention (CDC)-modified NBA (CDC-NBA), which includes preanalytic heat inactivation to liberate bound anti-FVIII antibodies. Methods Specimens with known inhibitors were tested with the CDC-NBA. IgG 4 anti-FVIII antibodies were measured by fluorescence immunoassay (FLI). Results Diluted inhibitors showed linearity below 0.4 Nijmegen-Bethesda units (NBU). With four statistical methods, the limit of detection of the CDC-NBA was determined to be 0.2 NBU. IgG 4 anti-FVIII antibodies, which correlate most strongly with functional inhibitors, were present at rates above the background rate of healthy controls in specimens with titers ≥ 0.2 NBU and showed an increase in frequency from 14.3% at 0.4 NBU to 67% at the established threshold for positivity of 0.5 NBU. Conclusions The CDC-NBA can detect inhibitors down to 0.2 NBU. The FLI, which is more sensitive, demonstrates anti-FVIII IgG 4 in some patients with negative (NBA, supporting the need for

  13. A diffusion-limited reaction model for self-propagating Al/Pt multilayers with quench limits

    Science.gov (United States)

    Kittell, D. E.; Yarrington, C. D.; Hobbs, M. L.; Abere, M. J.; Adams, D. P.

    2018-04-01

    A diffusion-limited reaction model was calibrated for Al/Pt multilayers ignited on oxidized silicon, sapphire, and tungsten substrates, as well as for some Al/Pt multilayers ignited as free-standing foils. The model was implemented in a finite element analysis code and used to match experimental burn front velocity data collected from several years of testing at Sandia National Laboratories. Moreover, both the simulations and experiments reveal well-defined quench limits in the total Al + Pt layer (i.e., bilayer) thickness. At these limits, the heat generated from atomic diffusion is insufficient to support a self-propagating wave front on top of the substrates. Quench limits for reactive multilayers are seldom reported and are found to depend on the thermal properties of the individual layers. Here, the diffusion-limited reaction model is generalized to allow for temperature- and composition-dependent material properties, phase change, and anisotropic thermal conductivity. Utilizing this increase in model fidelity, excellent overall agreement is shown between the simulations and experimental results with a single calibrated parameter set. However, the burn front velocities of Al/Pt multilayers ignited on tungsten substrates are over-predicted. Possible sources of error are discussed and a higher activation energy (from 41.9 kJ/mol.at. to 47.5 kJ/mol.at.) is shown to bring the simulations into agreement with the velocity data observed on tungsten substrates. This higher activation energy suggests an inhibited diffusion mechanism present at lower heating rates.

  14. Evaluation of uncertainty and detection limits in 210Pb and 210Po measurement in water by alpha spectrometry using 210Po spontaneous deposition onto a silver disk

    International Nuclear Information System (INIS)

    Fernández, Pedro L.; Gómez, José; Ródenas, Carmen

    2012-01-01

    An easy and accurate method for the determination of 210 Pb and 210 Po in water using 210 Po spontaneous deposition onto a silver disk is proposed and assessed for its detection capabilities according to the ISO Guide for the expression of uncertainty in measurement (GUM) and ISO Standard 11929-7 concerning the evaluation of the characteristic limits for ionizing radiation measurements. The method makes no assumption on the initial values of the activity concentrations of 210 Pb, 210 Bi and 210 Po in the sample to be analyzed, and is based on the alpha spectrometric measurement of 210 Po in two different aliquots: the first one measured five weeks after the sampling date to ensure radioactive equilibrium between 210 Pb and 210 Bi and the second after a sufficient time for the ingrowth of 210 Po from 210 Pb to be significant. As shown, for a recommended time interval of seven months between 210 Po measurements, the applicability of the proposed method is limited to water samples with a 226 Ra to 210 Pb activity ratio C Ra /C Pb ≤4, as usual in natural waters. Using sample and background counting times of 24 h and 240 h, respectively, the detection limit of the activity concentration of each radionuclide at the sampling time for a 1 L sample typically varies between 0.7 and 16 mBq L −1 for 210 Pb in water samples with an initial activity of 210 Po in the range 0–200 mBq L −1 , and between 0.6 and 8.5 mBq L −1 for 210 Po in water samples with an initial activity of 210 Pb in the same range. - Highlights: ► 210 Pb and 210 Po measurement in water by 210 Po spontaneous deposition onto silver disks. ► 210 Pb and 210 Po determination based on 210 Po measurement in two different aliquots. ► Evaluation of characteristic limits in radioactivity measurements using ISO 11929-7. ► 10 Pb - 210 Po detection limits decrease with time elapsed between 210 Po measurements.

  15. Does the Adoption of Plagiarism-Detection Software in Higher Education Reduce Plagiarism?

    Science.gov (United States)

    Youmans, Robert J.

    2011-01-01

    In two studies, students at California State University, Northridge wrote papers that were checked for plagiarism using plagiarism-detection software. In the first study, half of the students in two classes were randomly selected and told by the professor that their term papers would be scanned for plagiarism using the software. Students in the…

  16. Using rapid-scan EPR to improve the detection limit of quantitative EPR by more than one order of magnitude.

    Science.gov (United States)

    Möser, J; Lips, K; Tseytlin, M; Eaton, G R; Eaton, S S; Schnegg, A

    2017-08-01

    X-band rapid-scan EPR was implemented on a commercially available Bruker ELEXSYS E580 spectrometer. Room temperature rapid-scan and continuous-wave EPR spectra were recorded for amorphous silicon powder samples. By comparing the resulting signal intensities the feasibility of performing quantitative rapid-scan EPR is demonstrated. For different hydrogenated amorphous silicon samples, rapid-scan EPR results in signal-to-noise improvements by factors between 10 and 50. Rapid-scan EPR is thus capable of improving the detection limit of quantitative EPR by at least one order of magnitude. In addition, we provide a recipe for setting up and calibrating a conventional pulsed and continuous-wave EPR spectrometer for rapid-scan EPR. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Trichodesmium’s strategies to alleviate phosphorus limitation in the future acidified oceans.

    Science.gov (United States)

    Spungin, Dina; Berman-Frank, Ilana; Levitan, Orly

    2014-06-01

    Global warming may exacerbate inorganic nutrient limitation, including phosphorus (P), in the surface waters of tropical oceans that are home to extensive blooms of the marine diazotrophic cyanobacterium, Trichodesmium. We examined the combined effects of P limitation and pCO(2), forecast under ocean acidification scenarios, on Trichodesmium erythraeum IMS101 cultures. We measured nitrogen acquisition,glutamine synthetase activity, C uptake rates, intracellular Adenosine Triphosphate (ATP) concentration and the pool sizes of related key proteins. Here, we present data supporting the idea that cellular energy re-allocation enables the higher growth and N(2) fixation rates detected in Trichodesmium cultured under high pCO(2). This is reflected in altered protein abundance and metabolic pools. Also modified are particulate organic carbon and nitrogen production rates,enzymatic activities, and cellular ATP concentrations. We suggest that adjusting these cellular pathways to changing environmental conditions enables Trichodesmium to compensate for low P availability and to thrive in acidified oceans. Moreover, elevated pCO(2) could provide Trichodesmium with a competitive dominance that would extend its niche, particularly in P-limited regions of the tropical and subtropical oceans.

  18. Non-destructive micro-X-ray diffraction analysis of painted artefacts: Determination of detection limits for the chromium oxide-zinc oxide matrix

    International Nuclear Information System (INIS)

    Nel, P.; Lau, D.; Hay, D.; Wright, N.

    2006-01-01

    The development of micro-X-ray diffraction (micro-XRD) enables non-destructive, in situ analysis of crystalline pigments on artworks and archaeological objects. Pigments with X-ray diffraction patterns with large peak intensities may complicate the identification of other components with lower absorption coefficients, especially if present in low concentrations in the paint sample. Investigation of this issue involved: (1) micro-XRD examination and analysis of the amorphous and crystalline phases of fifteen pigment films and (2) micro-XRD examination and semi-quantitative analysis of various chromium oxide-zinc oxide mixtures, which established detection limits as low as 5 ± 2%

  19. Free transfer, limited mobility: A decade of higher education reform in Egypt and Morocco

    Directory of Open Access Journals (Sweden)

    Florian Kohstall

    2012-07-01

    Full Text Available This article aims to demonstrate how countries with a relative low performance in higher education like Egypt and Morocco, are informed and worked by the forces of internationalization in this domain. It compares the path of university reforms in both countries over the last decade, from their emergence on the agenda to their implementation. Through the lenses of a public policy approach it illustrates how higher education is subject to a complex negotiation process between international organizations and domestic policy-makers. The transfer of international models like grant-based funding and the Bologna process has become the driving force of these reforms. But when imposed through a top-down approach these models do not necessarily bring about the outcome they might have promised. They rather illustrate an example of distorted internationalization.

  20. The Cu-MOF-199/single-walled carbon nanotubes modified electrode for simultaneous determination of hydroquinone and catechol with extended linear ranges and lower detection limits

    International Nuclear Information System (INIS)

    Zhou, Jian; Li, Xi; Yang, Linlin; Yan, Songlin; Wang, Mengmeng; Cheng, Dan; Chen, Qi; Dong, Yulin; Liu, Peng; Cai, Weiquan; Zhang, Chaocan

    2015-01-01

    A novel electrochemical sensor based on Cu-MOF-199 [Cu-MOF-199 = Cu 3 (BTC) 2 (BTC = 1,3,5-benzenetricarboxylicacid)] and SWCNTs (single-walled carbon nanotubes) was fabricated for the simultaneous determination of hydroquinone (HQ) and catechol (CT). The modification procedure was carried out through casting SWCNTs on the bare glassy carbon electrode (GCE) and followed by the electrodeposition of Cu-MOF-199 on the SWCNTs modified electrode. Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) were performed to characterize the electrochemical performance and surface characteristics of the as-prepared sensor. The composite electrode exhibited an excellent electrocatalytic activity with increased electrochemical signals towards the oxidation of HQ and CT, owing to the synergistic effect of SWCNTs and Cu-MOF-199. Under the optimized condition, the linear response range were from 0.1 to 1453 μmol L −1 (R HQ  = 0.9999) for HQ and 0.1–1150 μmol L −1 (R CT  = 0.9990) for CT. The detection limits for HQ and CT were as low as 0.08 and 0.1 μmol L −1 , respectively. Moreover, the modified electrode presented the good reproducibility and the excellent anti-interference performance. The analytical performance of the developed sensor for the simultaneous detection of HQ and CT had been evaluated in practical samples with satisfying results. - Highlights: • Cu-MOF-199/SWCNTs/GCE was facilely fabricated by the electrodeposition on SWCNTs/GCE. • An electrochemical sensor for detecting HQ and CT was constructed based on this modified electrode. • The proposed electrochemical sensor showed an extended linear range and lower detection limits. • The proposed electrochemical sensor had an excellent stability and reproducibility.

  1. A need for standardization in drinking water analysis – an investigation of DNA extraction procedure, primer choice and detection limit of 16S rRNA amplicon sequencing

    DEFF Research Database (Denmark)

    Brandt, Jakob; Nielsen, Per Halkjær; Albertsen, Mads

    have been made to illuminate the effects specifically related to bacterial communities in drinking water. In this study, we investigated the impact of the DNA extraction and primer choice on the observed community structure, and we also estimated the detection limit of the 16S rRNA amplicon sequencing...

  2. Supervised detection of exoplanets in high-contrast imaging sequences

    Science.gov (United States)

    Gomez Gonzalez, C. A.; Absil, O.; Van Droogenbroeck, M.

    2018-06-01

    Context. Post-processing algorithms play a key role in pushing the detection limits of high-contrast imaging (HCI) instruments. State-of-the-art image processing approaches for HCI enable the production of science-ready images relying on unsupervised learning techniques, such as low-rank approximations, for generating a model point spread function (PSF) and subtracting the residual starlight and speckle noise. Aims: In order to maximize the detection rate of HCI instruments and survey campaigns, advanced algorithms with higher sensitivities to faint companions are needed, especially for the speckle-dominated innermost region of the images. Methods: We propose a reformulation of the exoplanet detection task (for ADI sequences) that builds on well-established machine learning techniques to take HCI post-processing from an unsupervised to a supervised learning context. In this new framework, we present algorithmic solutions using two different discriminative models: SODIRF (random forests) and SODINN (neural networks). We test these algorithms on real ADI datasets from VLT/NACO and VLT/SPHERE HCI instruments. We then assess their performances by injecting fake companions and using receiver operating characteristic analysis. This is done in comparison with state-of-the-art ADI algorithms, such as ADI principal component analysis (ADI-PCA). Results: This study shows the improved sensitivity versus specificity trade-off of the proposed supervised detection approach. At the diffraction limit, SODINN improves the true positive rate by a factor ranging from 2 to 10 (depending on the dataset and angular separation) with respect to ADI-PCA when working at the same false-positive level. Conclusions: The proposed supervised detection framework outperforms state-of-the-art techniques in the task of discriminating planet signal from speckles. In addition, it offers the possibility of re-processing existing HCI databases to maximize their scientific return and potentially improve

  3. A Game Theoretic Fault Detection Filter

    Science.gov (United States)

    Chung, Walter H.; Speyer, Jason L.

    1995-01-01

    The fault detection process is modelled as a disturbance attenuation problem. The solution to this problem is found via differential game theory, leading to an H(sub infinity) filter which bounds the transmission of all exogenous signals save the fault to be detected. For a general class of linear systems which includes some time-varying systems, it is shown that this transmission bound can be taken to zero by simultaneously bringing the sensor noise weighting to zero. Thus, in the limit, a complete transmission block can he achieved, making the game filter into a fault detection filter. When we specialize this result to time-invariant system, it is found that the detection filter attained in the limit is identical to the well known Beard-Jones Fault Detection Filter. That is, all fault inputs other than the one to be detected (the "nuisance faults") are restricted to an invariant subspace which is unobservable to a projection on the output. For time-invariant systems, it is also shown that in the limit, the order of the state-space and the game filter can be reduced by factoring out the invariant subspace. The result is a lower dimensional filter which can observe only the fault to be detected. A reduced-order filter can also he generated for time-varying systems, though the computational overhead may be intensive. An example given at the end of the paper demonstrates the effectiveness of the filter as a tool for fault detection and identification.

  4. Attempts to lower the detection limits of heavy metals in standardized grass cultures by using alternative growth substrates

    International Nuclear Information System (INIS)

    Winter, A.; Mueller, P.; Wagner, G.

    1992-01-01

    In addition to the use of standardized grass cultures (cf. VDI 3792) within the framework of an effect cadastre, grass cultures were tested on two non-contaminated substrates with nutrient solution in the greenhouse and in the open land during different exposure cycles. The results: As compared to the standard cultures on standardized soil, the cultures have the same or a better growth performance and better dry resistance on the artificial substrates; the blind values and the refore the detection limits in particular for cadmium are by far lower; four-week exposure periods with a two-week overlap have an improved information yield for the same amount of work throughout the investigation period as compared to a two-week exposure. Recommendations are derived from the results for a simplified application of the grass culture method in practice. (orig.) [de

  5. Ultrafast electron microscopy integrated with a direct electron detection camera.

    Science.gov (United States)

    Lee, Young Min; Kim, Young Jae; Kim, Ye-Jin; Kwon, Oh-Hoon

    2017-07-01

    In the past decade, we have witnessed the rapid growth of the field of ultrafast electron microscopy (UEM), which provides intuitive means to watch atomic and molecular motions of matter. Yet, because of the limited current of the pulsed electron beam resulting from space-charge effects, observations have been mainly made to periodic motions of the crystalline structure of hundreds of nanometers or higher by stroboscopic imaging at high repetition rates. Here, we develop an advanced UEM with robust capabilities for circumventing the present limitations by integrating a direct electron detection camera for the first time which allows for imaging at low repetition rates. This approach is expected to promote UEM to a more powerful platform to visualize molecular and collective motions and dissect fundamental physical, chemical, and materials phenomena in space and time.

  6. Higher-Spin Triplet Fields and String Theory

    Directory of Open Access Journals (Sweden)

    D. Sorokin

    2010-01-01

    Full Text Available We review basic properties of reducible higher-spin multiplets, called triplets, and demonstrate how they naturally appear as part of the spectrum of String Field Theory in the tensionless limit. We show how in the frame-like formulation the triplet fields are endowed with the geometrical meaning of being components of higher-spin vielbeins and connections and present actions describing their free dynamics.

  7. Remote detection of electronic devices

    Science.gov (United States)

    Judd, Stephen L [Los Alamos, NM; Fortgang, Clifford M [Los Alamos, NM; Guenther, David C [Los Alamos, NM

    2012-09-25

    An apparatus and method for detecting solid-state electronic devices are described. Non-linear junction detection techniques are combined with spread-spectrum encoding and cross correlation to increase the range and sensitivity of the non-linear junction detection and to permit the determination of the distances of the detected electronics. Nonlinear elements are detected by transmitting a signal at a chosen frequency and detecting higher harmonic signals that are returned from responding devices.

  8. Landscape genetics and limiting factors

    Science.gov (United States)

    Samuel A. Cushman; Andrew J. Shirk; Erin L. Landguth

    2013-01-01

    Population connectivity is mediated by the movement of organisms or propagules through landscapes. However, little is known about how variation in the pattern of landscape mosaics affects the detectability of landscape genetic relationships. The goal of this paper is to explore the impacts of limiting factors on landscape genetic processes using simulation...

  9. Large scale surveys suggest limited mercury availability in tropical north Queensland (Australia)

    International Nuclear Information System (INIS)

    Jardine, Timothy D.; Halliday, Ian A.; Howley, Christina; Sinnamon, Vivian; Bunn, Stuart E.

    2012-01-01

    Little is known about the threat of mercury (Hg) to consumers in food webs of Australia's wet–dry tropics. This is despite high concentrations in similar biomes elsewhere and a recent history of gold mining that could lead to a high degree of exposure for biota. We analysed Hg in water, sediments, invertebrates and fishes in rivers and estuaries of north Queensland, Australia to determine its availability and biomagnification in food webs. Concentrations in water and sediments were low relative to other regions of Hg concern, with only four of 138 water samples and five of 60 sediment samples above detection limits of 0.1 μg L −1 and 0.1 μg g −1 , respectively. Concentrations of Hg in fishes and invertebrates from riverine and wetland food webs were well below international consumption guidelines, including those in piscivorous fishes, likely due to low baseline concentrations and limited rates of biomagnification (average slope of log Hg vs. δ 15 N = 0.08). A large fish species of recreational, commercial, and cultural importance (the barramundi, Lates calcarifer), had low concentrations that were below consumption guidelines. Observed variation in Hg concentrations in this species was primarily explained by age and foraging location (floodplain vs. coastal), with floodplain feeders having higher Hg concentrations than those foraging at sea. These analyses suggest that there is a limited threat of Hg exposure for fish-eating consumers in this region. - Highlights: ► Hg concentrations in freshwaters and sediments of north Queensland were low. ► Biomagnification of Hg through riverine food webs was limited. ► Barramundi, a predatory fish, had low concentrations meaning low risk for consumers. ► Floodplain-feeding barramundi had higher Hg concentrations than coastal feeders.

  10. Sensitive detection of chlorine in iron oxide by single pulse and dual pulse laser-induced breakdown spectroscopy

    Science.gov (United States)

    Pedarnig, J. D.; Haslinger, M. J.; Bodea, M. A.; Huber, N.; Wolfmeir, H.; Heitz, J.

    2014-11-01

    The halogen chlorine is hard to detect in laser-induced breakdown spectroscopy (LIBS) mainly due to its high excited state energies of 9.2 and 10.4 eV for the most intense emission lines at 134.72 nm and 837.59 nm, respectively. We report on sensitive detection of Cl in industrial iron oxide Fe2O3 powder by single-pulse (SP) and dual-pulse (DP) LIBS measurements in the near infrared range in air. In compacted powder measured by SP excitation (Nd:YAG laser, 532 nm) Cl was detected with limit of detection LOD = 440 ppm and limit of quantitation LOQ = 720 ppm. Orthogonal DP LIBS was studied on pressed Fe2O3 pellets and Fe3O4 ceramics. The transmission of laser-induced plasma for orthogonal Nd:YAG 1064 nm and ArF 193 nm laser pulses showed a significant dependence on interpulse delay time (ipd) and laser wavelength (λL). The UV pulses (λL = 193 nm) were moderately absorbed in the plasma and the Cl I emission line intensity was enhanced while IR pulses (λL = 1064 nm) were not absorbed and Cl signals were not enhanced at ipd = 3 μs. The UV laser enhancement of Cl signals is attributed to the much higher signal/background ratio for orthogonal DP excitation compared to SP excitation and to the increased plasma temperature and electron number density. This enabled measurement at a very short delay time of td ≥ 0.1 μs with respect to the re-excitation pulse and detection of the very rapidly decaying Cl emission with higher efficiency.

  11. A reduced graphene oxide based electrochemical biosensor for tyrosine detection

    Science.gov (United States)

    Wei, Junhua; Qiu, Jingjing; Li, Li; Ren, Liqiang; Zhang, Xianwen; Chaudhuri, Jharna; Wang, Shiren

    2012-08-01

    In this paper, a ‘green’ and safe hydrothermal method has been used to reduce graphene oxide and produce hemin modified graphene nanosheet (HGN) based electrochemical biosensors for the determination of l-tyrosine levels. The as-fabricated HGN biosensors were characterized by UV-visible absorption spectra, fluorescence spectra, Fourier transform infrared spectroscopy (FTIR) spectra and thermogravimetric analysis (TGA). The experimental results indicated that hemin was successfully immobilized on the reduced graphene oxide nanosheet (rGO) through π-π interaction. TEM images and EDX results further confirmed the attachment of hemin on the rGO nanosheet. Cyclic voltammetry tests were carried out for the bare glass carbon electrode (GCE), the rGO electrode (rGO/GCE), and the hemin-rGO electrode (HGN/GCE). The HGN/GCE based biosensor exhibits a tyrosine detection linear range from 5 × 10-7 M to 2 × 10-5 M with a detection limitation of 7.5 × 10-8 M at a signal-to-noise ratio of 3. The sensitivity of this biosensor is 133 times higher than that of the bare GCE. In comparison with other works, electroactive biosensors are easily fabricated, easily controlled and cost-effective. Moreover, the hemin-rGO based biosensors demonstrate higher stability, a broader detection linear range and better detection sensitivity. Study of the oxidation scheme reveals that the rGO enhances the electron transfer between the electrode and the hemin, and the existence of hemin groups effectively electrocatalyzes the oxidation of tyrosine. This study contributes to a widespread clinical application of nanomaterial based biosensor devices with a broader detection linear range, improved stability, enhanced sensitivity and reduced costs.

  12. Evaluation of a technique for the intraoperative detection of a radiolabelled monoclonal antibody against colorectal cancer

    International Nuclear Information System (INIS)

    Waddington, W.A.; Todd-Pokropek, A.; Short, M.D.; Davidson, B.R.; Boulos, P.B.; Middlesex Hospital, London

    1991-01-01

    Occult tumour deposits may be localised at operation with a radiation detecting probe following the administration of a radiolabelled monoclonal antibody (MoAb) recognising a tumour-associated antigen. We have recently evaluated the clinical usefulness of this technique in detecting primary colorectal tumours targetted with an indium-111 MoAb. In the present study the physical characteristics of the two detector systems used were investigated; a sodium iodide [NaI(Tl)] scintilation detector and a cadmium telluride (CdTe) semiconductor probe. Limitations of the technique in use have been examined by testing the statistical significance of tumour detecting using an abdominal phantom based on the currently available clinical biodistribution data for tumour uptake of radiolabelled MoAbs. The effect of tumour volume, antibody uptake, collimation and counting conditions was examined. Results indicate that tumours of 10-ml volume may be detected with the NaI(Tl) probe at the lowest levels of radiolabelled antibody uptake currently reported in the literature but that at higher published levels, lesions as small as 1 ml may be identified with both detector systems. Detector sensitivity and limited antibody specificity restrict the usefulness of the technique, although moderate improvements in tumour uptake may allow the detection of tumour deposits not clinically apparent. The statistical significance criterion used for this study could be an accurate and reliable indicator for tumour detection in vivo. (orig.)

  13. Development of a loop-mediated isothermal amplification assay for detection of Trichomonas vaginalis.

    Science.gov (United States)

    Reyes, John Carlo B; Solon, Juan Antonio A; Rivera, Windell L

    2014-07-01

    A loop-mediated isothermal amplification (LAMP) assay targeting the 2-kbp repeated DNA species-specific sequence was developed for detection of Trichomonas vaginalis, the causative agent of trichomoniasis. The analytical sensitivity and specificity of the LAMP assay were evaluated using pooled genital swab and urine specimens, respectively, spiked with T. vaginalis trophozoites. Genital secretion and urine did not inhibit the detection of the parasite. The sensitivity of the LAMP was 10-1000 times higher than the PCR performed. The detection limit of LAMP was 1 trichomonad for both spiked genital swab and urine specimens. Also, LAMP did not exhibit cross-reactivity with closely-related trichomonads, Trichomonas tenax and Pentatrichomonas hominis, and other enteric and urogenital microorganisms, Entamoeba histolytica, Candida albicans, Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus. This is the first report of a LAMP assay for the detection of T. vaginalis and has prospective application for rapid diagnosis and control of trichomoniasis. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Electrical impedance scanning as a new imaging modality in breast cancer detection - a short review of clinical value on breast application, limitations and perspectives

    International Nuclear Information System (INIS)

    Malich, A.; Boehm, T.; Facius, M.; Kleinteich, I.; Fleck, M.; Sauner, D.; Anderson, R.; Kaiser, W.A.

    2003-01-01

    Objective. Cancer cells exhibit altered local dielectric properties compared to normal cells, measurable as different electrical conductance and capacitance using electrical impedance scanning (EIS). Therefore, active biocompatible current is applied to the patient for calculation of both parameters taking into account frequency, voltage and current flow. Subjects and methods. 240 women with 280 sonographically and/or mammographically suspicious findings were examined using EIS. All lesions were histologically proven. A lesion was scored as positive, when a focal increased conductance and/or capacitance was measurable using EIS. The lesion was visible as a bright area in a 256 grey-scale computer output. Due to system limitations patients having a pacemaker or pregnant had to be excluded from the study. Results. 91/113 malignant and 108/167 benign lesions were correctly identified using EIS (80.5% sensitivity, 64.7% specificity). NPV and PPV of 83.1% and 60.7% were observed, respectively. Accuracy was 0.73. A wide range of factors can induce false positive results, although by an experienced observer a number of these findings can be detected such as scars, skin alterations, contact artefacts, air bubbles and naevi, hairs and interfering bone. Based upon visibility on ultrasound (194 lesions visible, 86 not visible) significant differences in the detection rate occurred. Histology-dependent detectability rate varied significantly with lowest rate in CIS-cases (50%). Specificity values varied histology-depending, too; probably depending on the rate of proliferation between 75% (inflammatory lesions) and papillomata (50%). Best detectability was observed in malignant lesions with a size between 20 and 30 mm. Further possible applications will be discussed regarding the currently available literature (lymph nodes, salivary glands, mathematical and animal based models). Conclusion. EIS appears to be a promising new additional technology providing a rather high

  15. Probe-Specific Procedure to Estimate Sensitivity and Detection Limits for 19F Magnetic Resonance Imaging.

    Directory of Open Access Journals (Sweden)

    Alexander J Taylor

    Full Text Available Due to low fluorine background signal in vivo, 19F is a good marker to study the fate of exogenous molecules by magnetic resonance imaging (MRI using equilibrium nuclear spin polarization schemes. Since 19F MRI applications require high sensitivity, it can be important to assess experimental feasibility during the design stage already by estimating the minimum detectable fluorine concentration. Here we propose a simple method for the calibration of MRI hardware, providing sensitivity estimates for a given scanner and coil configuration. An experimental "calibration factor" to account for variations in coil configuration and hardware set-up is specified. Once it has been determined in a calibration experiment, the sensitivity of an experiment or, alternatively, the minimum number of required spins or the minimum marker concentration can be estimated without the need for a pilot experiment. The definition of this calibration factor is derived based on standard equations for the sensitivity in magnetic resonance, yet the method is not restricted by the limited validity of these equations, since additional instrument-dependent factors are implicitly included during calibration. The method is demonstrated using MR spectroscopy and imaging experiments with different 19F samples, both paramagnetically and susceptibility broadened, to approximate a range of realistic environments.

  16. Probe-Specific Procedure to Estimate Sensitivity and Detection Limits for 19F Magnetic Resonance Imaging.

    Science.gov (United States)

    Taylor, Alexander J; Granwehr, Josef; Lesbats, Clémentine; Krupa, James L; Six, Joseph S; Pavlovskaya, Galina E; Thomas, Neil R; Auer, Dorothee P; Meersmann, Thomas; Faas, Henryk M

    2016-01-01

    Due to low fluorine background signal in vivo, 19F is a good marker to study the fate of exogenous molecules by magnetic resonance imaging (MRI) using equilibrium nuclear spin polarization schemes. Since 19F MRI applications require high sensitivity, it can be important to assess experimental feasibility during the design stage already by estimating the minimum detectable fluorine concentration. Here we propose a simple method for the calibration of MRI hardware, providing sensitivity estimates for a given scanner and coil configuration. An experimental "calibration factor" to account for variations in coil configuration and hardware set-up is specified. Once it has been determined in a calibration experiment, the sensitivity of an experiment or, alternatively, the minimum number of required spins or the minimum marker concentration can be estimated without the need for a pilot experiment. The definition of this calibration factor is derived based on standard equations for the sensitivity in magnetic resonance, yet the method is not restricted by the limited validity of these equations, since additional instrument-dependent factors are implicitly included during calibration. The method is demonstrated using MR spectroscopy and imaging experiments with different 19F samples, both paramagnetically and susceptibility broadened, to approximate a range of realistic environments.

  17. Limits in feature-based attention to multiple colors.

    Science.gov (United States)

    Liu, Taosheng; Jigo, Michael

    2017-11-01

    Attention to a feature enhances the sensory representation of that feature. Although much has been learned about the properties of attentional modulation when attending to a single feature, the effectiveness of attending to multiple features is not well understood. We investigated this question in a series of experiments using a color-detection task while varying the number of attended colors in a cueing paradigm. Observers were shown either a single cue, two cues, or no cue (baseline) before detecting a coherent color target. We measured detection threshold by varying the coherence level of the target. Compared to the baseline condition, we found consistent facilitation of detection performance in the one-cue and two-cue conditions, but performance in the two-cue condition was lower than that in the one-cue condition. In the final experiment, we presented a 50% valid cue to emulate the situation in which observers were only able to attend a single color in the two-cue condition, and found equivalent detection thresholds with the standard two-cue condition. These results indicate a limit in attending to two colors and further imply that observers could effectively attend a single color at a time. Such a limit is likely due to an inability to maintain multiple active attentional templates for colors.

  18. Determination of chromium(VI) in water by PIXE analysis using ion exchange paper. Limit of detection and interference by coexisting anions

    International Nuclear Information System (INIS)

    Thomyasirigul, Sureerat; Fukuda, Hitoshi; Hasegawa, Jun; Oguri, Yoshiyuki

    2009-01-01

    Concerning the PIXE analysis of Cr(VI) in water using ion-exchange filters, the limit of detection (LOD) and the influence of matrix anions were investigated. In order to look for the experimental condition for obtaining the minimum LOD, we measured the Cr-Kα X-ray counts and background counts under the Kα X-ray peak as a function of the incident proton energy and the thickness of the Mylar absorber foil in front of the detector. To investigate the interference by coexisting anions, each of PO 4 3- , SO 4 2- , NO 3 - , Cl - , and F - ions and Cr(VI) ions were mixed in aqueous solutions and adsorbed on DE81-DEAE cellulose paper, a weakly basic anion exchanger with diethylaminoethyl functional groups. Then the filter samples were measured by PIXE using 2.5 MeV proton beams. We obtained a LOD of 0.16 μg or 8 ppb for 20 mL samples at a proton energy of 2.5 MeV and a Mylar film thickness of 50 or 100 μm. The experimental results on the mixed solutions indicated that NO 3 - , Cl - , and F - as coexisting ions didn't interfere significantly with determination of a 50 μg/L Cr(VI) concentration for 40 mL total solution volume, despite the total amount of anions was about 90% of ion exchange capacity of a filter. On the other hand, slight interferences by PO 4 3- ions were observed. However, under the same condition, we found that if the total amount of SO 4 2- ions was higher than 20% of ion exchange capacity, they induced significant interferences in determining Cr(VI). (author)

  19. Testing the discrimination and detection limits of WorldView-2 imagery on a challenging invasive plant target

    Science.gov (United States)

    Robinson, T. P.; Wardell-Johnson, G. W.; Pracilio, G.; Brown, C.; Corner, R.; van Klinken, R. D.

    2016-02-01

    Invasive plants pose significant threats to biodiversity and ecosystem function globally, leading to costly monitoring and management effort. While remote sensing promises cost-effective, robust and repeatable monitoring tools to support intervention, it has been largely restricted to airborne platforms that have higher spatial and spectral resolutions, but which lack the coverage and versatility of satellite-based platforms. This study tests the ability of the WorldView-2 (WV2) eight-band satellite sensor for detecting the invasive shrub mesquite (Prosopis spp.) in the north-west Pilbara region of Australia. Detectability was challenged by the target taxa being largely defoliated by a leaf-tying biological control agent (Gelechiidae: Evippe sp. #1) and the presence of other shrubs and trees. Variable importance in the projection (VIP) scores identified bands offering greatest capacity for discrimination were those covering the near-infrared, red, and red-edge wavelengths. Wavelengths between 400 nm and 630 nm (coastal blue, blue, green, yellow) were not useful for species level discrimination in this case. Classification accuracy was tested on three band sets (simulated standard multispectral, all bands, and bands with VIP scores ≥1). Overall accuracies were comparable amongst all band-sets (Kappa = 0.71-0.77). However, mesquite omission rates were unacceptably high (21.3%) when using all eight bands relative to the simulated standard multispectral band-set (9.5%) and the band-set informed by VIP scores (11.9%). An incremental cover evaluation on the latter identified most omissions to be for objects high mapping accuracy of objects >16 m2 allows application for mapping mesquite shrubs and coalesced stands, the former not previously possible, even with 3 m resolution hyperspectral imagery. WV2 imagery offers excellent portability potential for detecting other species where spectral/spatial resolution or coverage has been an impediment. New generation satellite

  20. Carbon Nanotube Biosensors for Space Molecule Detection and Clinical Molecular Diagnostics

    Science.gov (United States)

    Han, Jie

    2001-01-01

    Both space molecule detection and clinical molecule diagnostics need to develop ultra sensitive biosensors for detection of less than attomole molecules such as amino acids for DNA. However all the electrode sensor systems including those fabricated from the existing carbon nanotubes, have a background level of nA (nanoAmp). This has limited DNA or other molecule detection to nA level or molecules whose concentration is, much higher than attomole level. A program has been created by NASA and NCI (National Cancer Institute) to exploit the possibility of carbon nanotube based biosensors to solve this problem for both's interest. In this talk, I will present our effort on the evaluation and novel design of carbon nanotubes as electrode biosensors with strategies to minimize background currents while maximizing signal intensity.The fabrication of nanotube electrode arrays, immobilization of molecular probes on nanotube electrodes and in vitro biosensor testing will also be discussed.

  1. The Limits of Accountability.

    Science.gov (United States)

    Bailey, Stephen K.

    This discussion, presented at the Regent's Trustees' Conference, February 1973, reviews the limits of accountability in higher education. Managerial efficiency is suggested to assist in eliminating educational and financial waste. This, however, is the secondary concept emphasized. The primary emphasis indicates the legitimacy of the claims that a…

  2. AMS detection of actinides at high mass separation

    Energy Technology Data Exchange (ETDEWEB)

    Steier, Peter; Lachner, Johannes; Priller, Alfred; Winkler, Stephan; Golser, Robin [University of Vienna, Faculty of Physics, Vienna (Austria); Eigl, Rosmarie [Hiroshima University, Earth and Planetary Systems Science, Hiroshima (Japan); Quinto, Francesca [Institut fuer Nukleare Entsorgung, KIT, Eggenstein-Leopoldshafen (Germany); Sakaguchi, Aya [University of Tsukuba, Center for Research in Isotopes and Environmental Dynamics, Tsukuba (Japan)

    2015-07-01

    AMS is the mass spectrometric method with the highest abundance sensitivity, which is a prerequisite for measurement of the long-lived radioisotope {sup 236}U (t{sub 1/2}=23.4 million years). The most successful application so far is oceanography, since anthropogenic {sup 236}U is present in the world oceans at {sup 236}U:{sup 238}U from 10{sup -11} to 10{sup -8}. We have explored methods to increase the sensitivity and thus to reduce the water volume required to 1 L or less, which significantly reduces the sampling effort. High sensitivity is also necessary to address the expected typical natural isotopic ratios on the order {sup 236}U:{sup 238}U = 10{sup -13}, with potential applications in geology. With a second 90 analyzer magnet and a new Time-of-Flight beam line, VERA is robust against chemical impurities in the background, which e.g. allows measuring Pu isotopes directly in a uranium matrix. This simplifies chemical sample preparation for actinide detection, and may illustrate why AMS reaches lower detection limits than other mass spectrometric methods with nominally higher detection efficiency.

  3. Work and Leisure in Higher Education

    Science.gov (United States)

    Harris, David

    2012-01-01

    Higher education is commonly described as offering combinations of work and leisure, but the implied relationship is often limited. Different conceptions of leisure, especially leisure as pleasurable experience, raise new possibilities for seeing academic activity itself as leisure in several important senses. The importance of identifying…

  4. Changes in respiratory function impairment following the treatment of severe pulmonary tuberculosis - limitations for the underlying COPD detection.

    Science.gov (United States)

    Radovic, Milan; Ristic, Lidija; Ciric, Zorica; Dinic-Radovic, Violeta; Stankovic, Ivana; Pejcic, Tatjana; Rancic, Milan; Bogdanovic, Dragan

    2016-01-01

    During the treatment phase of active pulmonary tuberculosis (PTB), respiratory function impairment is usually restrictive. This may become obstructive, as a PTB-associated airflow obstruction (AFO) or as a later manifestation of underlying COPD. The aim of the study was to examine the potential causes and risks for AFO development in PTB by exploring the aspects of spirometry limitations and clinical implications for the underlying COPD detection, taking into account various confounding factors. Prospective, nest case-control study on 40 new cases of PTB with initial restrictive respiratory function impairment, diagnosed and treated according to the directly observed treatment short course (DOTS) strategy. From all observed patients, 37.5% of them developed AFO upon the completion of PTB treatment, with significantly increased average of forced vital capacity (%) (Ppulmonary tuberculosis lesions (OR 1.01-1.05 for 95% CI; P=0.02) and sputum conversion rate on culture (OR 1.02-1.68 for 95% CI; P=0.04) as the most significant predictors for the risk of AFO development. AFO upon PTB treatment is a common manifestation of underlying COPD, which mostly occurs later, during the reparative processes in active PTB, even in the absence of major risk factors, such as cigarette smoking and biomass fuel dust exposure. Initial spirometry testing in patients with active PTB is not a sufficient and accurate approach in the detection of underlying COPD, which may lead to their further potential health deterioration.

  5. Limitations and Strengths of the Fourier Transform Method to Detect Accelerating Targets

    National Research Council Canada - National Science Library

    Thayaparan, Thayananthan

    2000-01-01

    .... In using a Pulse Doppler Radar to detect a non-accelerating target in additive white Gaussian noise and to estimate its radial velocity, the Fourier method provides an output signal-to-noise ratio (SNR...

  6. Detection in superheated water chromatography

    International Nuclear Information System (INIS)

    Chienthavorn, O.

    1999-11-01

    Superheated water has been used successfully as an eluent in liquid chromatography and has been coupled to various modes of detection, ultraviolet (UV), fluorescence, and nuclear magnetic resonance spectroscopy (NMR) and mass spectrometry (MS). A number of compounds were examined on poly(styrene-divinylbenzene) (PS-DVB), polybutadiene (PBD), and octadecylsilyl bonded silica (ODS) column with isothermal and temperature programmes. The PS-DVB column was mostly used throughout the project as it was the most stable. Not only pure water could serve as superheated water mobile phase; inorganic buffered water and ion-pairing reagent with a concentration of 1-3 mM of the buffer and reagent were also exploited. It was shown that the pH could be controlled during the separation without salt precipitation and the separations followed a conventional reversed-phase HPLC method. Results from fluorescence detection showed good separation of a series of vitamins, such as pyridoxine, riboflavin, thiamine, and some analgesics. The relationship of riboflavin using the detection was linear and the detection limit was seven times higher than that of a conventional method. Simultaneous separation and identification using superheated water chromatography-NMR was demonstrated. With using a stop flow method, NMR spectra of model drugs, namely barbiturates, paracetamol, caffeine and phenacetin were obtained and the results agreed with reference spectra, confirming a perfect separation. A demonstration to obtain COSY spectrum of salicylamide was also performed. The method was expanded to the coupling of superheated water LC to NMR-MS. Results from the hyphenated detection method showed that deuteration and degradation happened in the superheated water conditions. The methyl group hydrogens of pyrimidine ring of sulfonamide and thiamine were exchanged with deuterium. Thiamine was decomposed to 4-methyl-5-thiazoleethanol and both were deuterated under the conditions. (author)

  7. Optimising the design of gas microstrip detectors for soft x-ray detection

    International Nuclear Information System (INIS)

    Bateman, J.; Barlow, R.; Derbyshire, G.

    2001-01-01

    This report describes development work in which systematic changes in the electrode pattern of a Gas Microstrip Detector are explored in the search for higher avalanche gains and enhanced stability. It is found that the width of the cathode structure is the main determinant of the detector stability. With the correct cathode width, gas gains of >50 000 are comfortably attainable with low detector noise so that x-rays can potentially be detected down to the limit of a single x-ray-produced photoelectron. (author)

  8. Integrating reaction and analysis: investigation of higher-order reactions by cryogenic trapping

    Directory of Open Access Journals (Sweden)

    Skrollan Stockinger

    2013-09-01

    Full Text Available A new approach for the investigation of a higher-order reaction by on-column reaction gas chromatography is presented. The reaction and the analytical separation are combined in a single experiment to investigate the Diels–Alder reaction of benzenediazonium-2-carboxylate as a benzyne precursor with various anthracene derivatives, i.e. anthracene, 9-bromoanthracene, 9-anthracenecarboxaldehyde and 9-anthracenemethanol. To overcome limitations of short reaction contact times at elevated temperatures a novel experimental setup was developed involving a cooling trap to achieve focusing and mixing of the reactants at a defined spot in a fused-silica capillary. This trap functions as a reactor within the separation column in the oven of a gas chromatograph. The reactants are sequentially injected to avoid undefined mixing in the injection port. An experimental protocol was developed with optimized injection intervals and cooling times to achieve sufficient conversions at short reaction times. Reaction products were rapidly identified by mass spectrometric detection. This new approach represents a practical procedure to investigate higher-order reactions at an analytical level and it simultaneously provides valuable information for the optimization of the reaction conditions.

  9. Determination of bisphenol A in human serum by high-performance liquid chromatography with multi-electrode electrochemical detection.

    Science.gov (United States)

    Inoue, K; Kato, K; Yoshimura, Y; Makino, T; Nakazawa, H

    2000-11-10

    A simple and sensitive method using high-performance liquid chromatography with multi-electrode electrochemical detection (HPLC-ED) including a coulometric array of four electrochemical sensors has been developed for the determination of bisphenol A in water and human serum. For good separation and detection of bisphenol A, a CAPCELL PAK UG 120 C18 reversed-phase column and a mobile phase consisting of 0.3% phosphoric acid-acetonitrile (60:40) were used. The detection limit obtained by the HPLC-ED method was 0.01 ng/ml (0.5 pg), which was more than 3000-times higher than the detection limit obtained by the ultraviolet (UV) method, and more than 200-times higher than the detection limit obtained by the fluorescence (FL) method. Bisphenol A in water and serum samples was pretreated by solid-phase extraction (SPE) after removing possible contamination derived from a plastic SPE cartridges and water used for the pretreatment. A trace amount (ND approximately 0.013 ng/ml) of bisphenol A was detected from the parts of cartridges (filtration column, sorbent bed and frits) by extraction with methanol, and it was completely removed by washing with at least 15 ml of methanol in the operation process. The concentrations of bisphenol A in tap water and Milli-Q-purified water were found to be 0.01 and 0.02 ng/ml, respectively. For that reason, bisphenol A-free water was made to trap bisphenol A in water using an Empore disk. In every pretreatment, SPE methods using bisphenol A-free water and washing with 15 ml of methanol were done in water and serum samples. The yields obtained from the recovery tests using water to which 0.5 or 0.05 ng/ml of bisphenol A was added were 83.8 to 98.2%, and the RSDs were 3.4 to 6.1%, respectively. The yields obtained from the recovery tests by OASIS HLB using serum to which 1.0 ng/ml or 0.1 ng/ml of bisphenol A was added were 79.0% and 87.3%, and the RSDs were 5.1% and 13.5%, respectively. The limits of quantification in water and serum sample

  10. Direct immobilization of antibodies on Zn-doped Fe_3O_4 nanoclusters for detection of pathogenic bacteria

    International Nuclear Information System (INIS)

    Pal, Monalisa; Lee, Sanghee; Kwon, Donghoon; Hwang, Jeongin; Lee, Hyeonjeong; Hwang, Seokyung; Jeon, Sangmin

    2017-01-01

    Zinc-doped magnetic nanoclusters (Zn-MNCs) were synthesized and used to detect pathogenic bacteria in milk. Hydrothermally synthesized Zn-MNCs exhibited stronger magnetic properties than pure MNCs, which facilitated the magnetic separation from the sample using a permanent magnet. The presence of accessible Zn sites allows the direct immobilization of half-fragmented antibodies over Zn-MNCs through strong Zn−S bonds and prevents the tedious multiple steps of molecular functionalization or coating with costly noble metals prior to conjugation with an antibody. After the capture and magnetic separation of Salmonella in milk using the antibody-functionalized Zn-MNCs, the concentration of bacteria was determined with a portable ATP luminometer and the detection limit was found to be 10 CFU/mL. - Highlights: • Zn-doped Fe_3O_4 nanoclusters (Zn-MNCs) were synthesized by hydrothermal method. • Antibodies were directly immobilized over Zn-MNCs through strong Zn–S_t_h_i_o_l bonds. • Higher magnetization of Zn-MNCs than pure MNCs facilitates the magnetic separation. • Detection limit of pathogenic bacteria in milk was found to be 10 cfu/mL. • Cost effective, sensitive and selective detection of bacteria.

  11. Photoacoustic Imaging in Oxygen Detection

    Directory of Open Access Journals (Sweden)

    Fei Cao

    2017-12-01

    Full Text Available Oxygen level, including blood oxygen saturation (sO2 and tissue oxygen partial pressure (pO2, are crucial physiological parameters in life science. This paper reviews the importance of these two parameters and the detection methods for them, focusing on the application of photoacoustic imaging in this scenario. sO2 is traditionally detected with optical spectra-based methods, and has recently been proven uniquely efficient by using photoacoustic methods. pO2, on the other hand, is typically detected by PET, MRI, or pure optical approaches, yet with limited spatial resolution, imaging frame rate, or penetration depth. Great potential has also been demonstrated by employing photoacoustic imaging to overcome the existing limitations of the aforementioned techniques.

  12. Water Exchange Produces Significantly Higher Adenoma Detection Rate Than Water Immersion: Pooled Data From 2 Multisite Randomized Controlled Trials.

    Science.gov (United States)

    Leung, Felix W; Koo, Malcolm; Cadoni, Sergio; Falt, Premysl; Hsieh, Yu-Hsi; Amato, Arnaldo; Erriu, Matteo; Fojtik, Petr; Gallittu, Paolo; Hu, Chi-Tan; Leung, Joseph W; Liggi, Mauro; Paggi, Silvia; Radaelli, Franco; Rondonotti, Emanuele; Smajstrla, Vit; Tseng, Chih-Wei; Urban, Ondrej

    2018-03-02

    To test the hypothesis that water exchange (WE) significantly increases adenoma detection rates (ADR) compared with water immersion (WI). Low ADR was linked to increased risk for interval colorectal cancers and related deaths. Two recent randomized controlled trials of head-to-head comparison of WE, WI, and traditional air insufflation (AI) each showed that WE achieved significantly higher ADR than AI, but not WI. The data were pooled from these 2 studies to test the above hypothesis. Two trials (5 sites, 14 colonoscopists) that randomized 1875 patients 1:1:1 to AI, WI, or WE were pooled and analyzed with ADR as the primary outcome. The ADR of AI (39.5%) and WI (42.4%) were comparable, significantly lower than that of WE (49.6%) (vs. AI P=0.001; vs. WI P=0.033). WE insertion time was 3 minutes longer than that of AI (Prate (vs. AI) of the >10 mm advanced adenomas. Right colon combined advanced and sessile serrated ADR of AI (3.4%) and WI (5%) were comparable and were significantly lower than that of WE (8.5%) (vs. AI P<0.001; vs. WI P=0.039). Compared with AI and WI, the superior ADR of WE offsets the drawback of a significantly longer insertion time. For quality improvement focused on increasing adenoma detection, WE is preferred over WI. The hypothesis that WE could lower the risk of interval colorectal cancers and related deaths should be tested.

  13. Efficient Bisphenol-A detection based on the ternary metal oxide (TMO) composite by electrochemical approaches

    International Nuclear Information System (INIS)

    Ahmed, Jahir; Rahman, Mohammed M.; Siddiquey, Iqbal A.; Asiri, Abdullah M.; Hasnat, Mohammad A.

    2017-01-01

    Highlights: •Ternary metal oxides (TMO) composites prepared by wet-chemical method. •Highly sensitive and selective Bisphenol A (BPA) sensor by I–V method. •Ultra-low detection limit was obtained by 3N/S. •Real environmental samples were analyzed. •Health care and environmental safety -- Abstract: A facile wet chemical method in basic medium was used to synthesis the ternary metal oxides (TMO; ZnO.CoO.FeO) composites at low temperature. The calcined TMO was characterized by FESEM, EDS, UV/vis., FTIR spectroscopy, EIS, and XRD systematically. Glassy carbon electrode (GCE) was modified with the TMO using 5% Nafion at room conditions. The resultant electrode was used for selective detection of Bisphenol-A (BPA) using cyclic voltammetry (CV). It was observed that the TMO electrode exhibited an excellent sensitivity (3.28 μAμM −1 cm −2 ), low detection limit (LOD: 1.2 ± 0.1 nM; S/N = 3), higher stability, very good repeatability, and reproducibility. In diagnostic exploration, a linear calibration plot was obtained for a wide range of concentration of BPA (LDR: 0.80 to 7.20 μM; r 2 : 0.99). This method represents an efficient way of sensitive sensor development for the detection of toxic and carcinogenic phenolic compounds.

  14. Electrochemical Microsensors for the Detection of Cadmium(II and Lead(II Ions in Plants

    Directory of Open Access Journals (Sweden)

    Olga Krystofova

    2010-05-01

    Full Text Available Routine determination of trace metals in complex media is still a difficult task for many analytical instruments. The aim of this work was to compare three electro-chemical instruments [a standard potentiostat (Autolab, a commercially available miniaturized potentiostat (PalmSens and a homemade micropotentiostat] for easy-to-use and sensitive determination of cadmium(II and lead(II ions. The lowest detection limits (hundreds of pM for both metals was achieved by using of the standard potentiostat, followed by the miniaturized potentiostat (tens of nM and the homemade instrument (hundreds of nM. Nevertheless, all potentiostats were sensitive enough to evaluate contamination of the environment, because the environmental limits for both metals are higher than detection limits of the instruments. Further, we tested all used potentiostats and working electrodes on analysis of environmental samples (rainwater, flour and plant extract with artificially added cadmium(II and lead(II. Based on the similar results obtained for all potentiostats we choose a homemade instrument with a carbon tip working electrode for our subsequent environmental experiments, in which we analyzed maize and sunflower seedlings and rainwater obtained from various sites in the Czech Republic.

  15. Limitations to depth resolution in high-energy, heavy-ion elastic recoil detection analysis

    International Nuclear Information System (INIS)

    Elliman, R.G.; Palmer, G.R.; Ophel, T.R.; Timmers, H.

    1998-01-01

    The depth resolution of heavy-ion elastic recoil detection analysis was examined for Al and Co thin films ranging in thickness from 100 to 400 nm. Measurements were performed with 154 MeV Au ions as the incident beam, and recoils were detected using a gas ionisation detector. Energy spectra were extracted for the Al and Co recoils and the depth resolution determined as a function of film thickness from the width of the high- and low- energy edges. These results were compared with theoretical estimates calculated using the computer program DEPTH. (authors)

  16. Detections and Sensitive Upper Limits for Methane and Related Trace Gases on Mars during 2003-2014, and planned extensions in 2016

    Science.gov (United States)

    Mumma, Michael J.; Villanueva, Geronimo L.; Novak, Robert E.

    2015-11-01

    Five groups report methane detections on Mars; all results suggest local release and high temporal variability [1-7]. Our team searched for CH4 on many dates and seasons and detected it on several dates [1, 9, 10]. TLS (Curiosity rover) reported methane upper limits [6], and then detections [7] that were consistent in size with earlier reports and that also showed rapid modulation of CH4 abundance.[8] argued that absorption features assigned to Mars 12CH4 by [1] might instead be weak lines of terrestrial 13CH4. If not properly removed, terrestrial 13CH4 signatures would appear on the blue wing of terrestrial 12CH4 even when Mars is red-shifted - but they do not (Fig. S6 of [1]), demonstrating that terrestrial signatures were correctly removed. [9] demonstrated that including the dependence of δ13CH4 with altitude did not affect the residual features, nor did taking δ13CH4 as zero. Were δ13CH4 important, its omission would have overemphasized the depth of 13CH4 terrestrial absorption, introducing emission features in the residual spectra [1]. However, the residual features are seen in absorption, establishing their origin as non-terrestrial - [8] now agrees with this view.We later reported results for multiple organic gases (CH4, CH3OH, H2CO, C2H6, C2H2, C2H4), hydroperoxyl (HO2), three nitriles (N2O, NH3, HCN) and two chlorinated species (HCl, CH3Cl) [9]. Most of these species cannot be detected with current space assets, owing to instrumental limitations (e.g., spectral resolving power). However, the high resolution infrared spectrometers (NOMAD, ACS) on ExoMars 2016 (Trace Gas Orbiter) will begin measurements in late 2016. In solar occultation, TGO sensitivities will far exceed prior capabilities.We published detailed hemispheric maps of H2O and HDO on Mars, inferring the size of a lost early ocean [10]. In 2016, we plan to acquire 3-D spatial maps of HDO and H2O with ALMA, and improved maps of organics with iSHELL/NASA-IRTF.References: [1] Mumma et al. Sci09

  17. Group-focused morality is associated with limited conflict detection and resolution capacity: Neuroanatomical evidence.

    Science.gov (United States)

    Nash, Kyle; Baumgartner, Thomas; Knoch, Daria

    2017-02-01

    Group-focused moral foundations (GMFs) - moral values that help protect the group's welfare - sharply divide conservatives from liberals and religiously devout from non-believers. However, there is little evidence about what drives this divide. Moral foundations theory and the model of motivated social cognition both associate group-focused moral foundations with differences in conflict detection and resolution capacity, but in opposing directions. Individual differences in conflict detection and resolution implicate specific neuroanatomical differences. Examining neuroanatomy thus affords an objective and non-biased opportunity to contrast these influential theories. Here, we report that increased adherence to group-focused moral foundations was strongly associated (whole-brain corrected) with reduced gray matter volume in key regions of the conflict detection and resolution system (anterior cingulate cortex and lateral prefrontal cortex). Because reduced gray matter is reliably associated with reduced neural and cognitive capacity, these findings support the idea outlined in the model of motivated social cognition that belief in group-focused moral values is associated with reduced conflict detection and resolution capacity. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Improvement of the qualitative and quantitative detection of simultaneously present fluorescent tracers by systematic sample treatment

    International Nuclear Information System (INIS)

    Behrens, H.

    1982-01-01

    The selective instrumental detection of individual fluorescent tracers in mixtures containing further fluorescent dyes is limited by spectral interferences. Therefore additional separations or other suitable procedures have to be included into the analytic technique. With the method described below, the respective tracer to be detected remains with its initial concentration in the sample and is analysed under the appropriate conditions, whereas the interfering tracers are separated or suppressed. The techniques applied for this base on the facts that 1) the fluorescence intensity of the tracers varies differently when the pH-value changes; 2) the tracers show different absorption behaviour and 3) they provide different degrees of light sensitivity. The procedures permit for example to detect uranin when eosin is present in a higher concentration or to detect eosin when amidorhodamin G is present. (orig.) [de

  19. Towards Sustainable Internationalisation of Higher Education

    Science.gov (United States)

    Ilieva, Roumiana; Beck, Kumari; Waterstone, Bonnie

    2014-01-01

    This article engages with the question: what does the internationalisation of higher education in times of globalisation sustain and what should it sustain? We first consider, through literature on globalisation and Stier's ("Glob Soc Educ" 2(1):1-28, 2004) work, limitations of currently prevalent perspectives on…

  20. Probabilistic pipe fracture evaluations for leak-rate-detection applications

    International Nuclear Information System (INIS)

    Rahman, S.; Ghadiali, N.; Paul, D.; Wilkowski, G.

    1995-04-01

    Regulatory Guide 1.45, open-quotes Reactor Coolant Pressure Boundary Leakage Detection Systems,close quotes was published by the U.S. Nuclear Regulatory Commission (NRC) in May 1973, and provides guidance on leak detection methods and system requirements for Light Water Reactors. Additionally, leak detection limits are specified in plant Technical Specifications and are different for Boiling Water Reactors (BWRs) and Pressurized Water Reactors (PWRs). These leak detection limits are also used in leak-before-break evaluations performed in accordance with Draft Standard Review Plan, Section 3.6.3, open-quotes Leak Before Break Evaluation Proceduresclose quotes where a margin of 10 on the leak detection limit is used in determining the crack size considered in subsequent fracture analyses. This study was requested by the NRC to: (1) evaluate the conditional failure probability for BWR and PWR piping for pipes that were leaking at the allowable leak detection limit, and (2) evaluate the margin of 10 to determine if it was unnecessarily large. A probabilistic approach was undertaken to conduct fracture evaluations of circumferentially cracked pipes for leak-rate-detection applications. Sixteen nuclear piping systems in BWR and PWR plants were analyzed to evaluate conditional failure probability and effects of crack-morphology variability on the current margins used in leak rate detection for leak-before-break

  1. The Need and Potential of Biosensors to Detect Dioxins and Dioxin-Like Polychlorinated Biphenyls along the Milk, Eggs and Meat Food Chain

    Directory of Open Access Journals (Sweden)

    Aize Kijlstra

    2011-12-01

    Full Text Available Dioxins and dioxin-like polychlorinated biphenyls (DL-PCBs are hazardous toxic, ubiquitous and persistent chemical compounds, which can enter the food chain and accumulate up to higher trophic levels. Their determination requires sophisticated methods, expensive facilities and instruments, well-trained personnel and expensive chemical reagents. Ideally, real-time monitoring using rapid detection methods should be applied to detect possible contamination along the food chain in order to prevent human exposure. Sensor technology may be promising in this respect. This review gives the state of the art for detecting possible contamination with dioxins and DL-PCBs along the food chain of animal-source foods. The main detection methods applied (i.e., high resolution gas-chromatography combined with high resolution mass-spectrometry (HRGC/HRMS and the chemical activated luciferase gene expression method (CALUX bioassay, each have their limitations. Biosensors for detecting dioxins and related compounds, although still under development, show potential to overcome these limitations. Immunosensors and biomimetic-based biosensors potentially offer increased selectivity and sensitivity for dioxin and DL-PCB detection, while whole cell-based biosensors present interpretable biological results. The main shortcoming of current biosensors, however, is their detection level: this may be insufficient as limits for dioxins and DL-PCBs for food and feedstuffs are in pg per gram level. In addition, these contaminants are normally present in fat, a difficult matrix for biosensor detection. Therefore, simple and efficient extraction and clean-up procedures are required which may enable biosensors to detect dioxins and DL-PCBs contamination along the food chain.

  2. The Need and Potential of Biosensors to Detect Dioxins and Dioxin-Like Polychlorinated Biphenyls along the Milk, Eggs and Meat Food Chain

    Science.gov (United States)

    Chobtang, Jeerasak; de Boer, Imke J. M.; Hoogenboom, Ron L. A. P.; Haasnoot, Willem; Kijlstra, Aize; Meerburg, Bastiaan G.

    2011-01-01

    Dioxins and dioxin-like polychlorinated biphenyls (DL-PCBs) are hazardous toxic, ubiquitous and persistent chemical compounds, which can enter the food chain and accumulate up to higher trophic levels. Their determination requires sophisticated methods, expensive facilities and instruments, well-trained personnel and expensive chemical reagents. Ideally, real-time monitoring using rapid detection methods should be applied to detect possible contamination along the food chain in order to prevent human exposure. Sensor technology may be promising in this respect. This review gives the state of the art for detecting possible contamination with dioxins and DL-PCBs along the food chain of animal-source foods. The main detection methods applied (i.e., high resolution gas-chromatography combined with high resolution mass-spectrometry (HRGC/HRMS) and the chemical activated luciferase gene expression method (CALUX bioassay)), each have their limitations. Biosensors for detecting dioxins and related compounds, although still under development, show potential to overcome these limitations. Immunosensors and biomimetic-based biosensors potentially offer increased selectivity and sensitivity for dioxin and DL-PCB detection, while whole cell-based biosensors present interpretable biological results. The main shortcoming of current biosensors, however, is their detection level: this may be insufficient as limits for dioxins and DL-PCBs for food and feedstuffs are in pg per gram level. In addition, these contaminants are normally present in fat, a difficult matrix for biosensor detection. Therefore, simple and efficient extraction and clean-up procedures are required which may enable biosensors to detect dioxins and DL-PCBs contamination along the food chain. PMID:22247688

  3. The need and potential of biosensors to detect dioxins and dioxin-like polychlorinated biphenyls along the milk, eggs and meat food chain.

    Science.gov (United States)

    Chobtang, Jeerasak; de Boer, Imke J M; Hoogenboom, Ron L A P; Haasnoot, Willem; Kijlstra, Aize; Meerburg, Bastiaan G

    2011-01-01

    Dioxins and dioxin-like polychlorinated biphenyls (DL-PCBs) are hazardous toxic, ubiquitous and persistent chemical compounds, which can enter the food chain and accumulate up to higher trophic levels. Their determination requires sophisticated methods, expensive facilities and instruments, well-trained personnel and expensive chemical reagents. Ideally, real-time monitoring using rapid detection methods should be applied to detect possible contamination along the food chain in order to prevent human exposure. Sensor technology may be promising in this respect. This review gives the state of the art for detecting possible contamination with dioxins and DL-PCBs along the food chain of animal-source foods. The main detection methods applied (i.e., high resolution gas-chromatography combined with high resolution mass-spectrometry (HRGC/HRMS) and the chemical activated luciferase gene expression method (CALUX bioassay)), each have their limitations. Biosensors for detecting dioxins and related compounds, although still under development, show potential to overcome these limitations. Immunosensors and biomimetic-based biosensors potentially offer increased selectivity and sensitivity for dioxin and DL-PCB detection, while whole cell-based biosensors present interpretable biological results. The main shortcoming of current biosensors, however, is their detection level: this may be insufficient as limits for dioxins and DL-PCBs for food and feedstuffs are in pg per gram level. In addition, these contaminants are normally present in fat, a difficult matrix for biosensor detection. Therefore, simple and efficient extraction and clean-up procedures are required which may enable biosensors to detect dioxins and DL-PCBs contamination along the food chain.

  4. Ultrafast electron microscopy integrated with a direct electron detection camera

    Directory of Open Access Journals (Sweden)

    Young Min Lee

    2017-07-01

    Full Text Available In the past decade, we have witnessed the rapid growth of the field of ultrafast electron microscopy (UEM, which provides intuitive means to watch atomic and molecular motions of matter. Yet, because of the limited current of the pulsed electron beam resulting from space-charge effects, observations have been mainly made to periodic motions of the crystalline structure of hundreds of nanometers or higher by stroboscopic imaging at high repetition rates. Here, we develop an advanced UEM with robust capabilities for circumventing the present limitations by integrating a direct electron detection camera for the first time which allows for imaging at low repetition rates. This approach is expected to promote UEM to a more powerful platform to visualize molecular and collective motions and dissect fundamental physical, chemical, and materials phenomena in space and time.

  5. Inherent Limitations in Mid-Wave and Long-Wave-IR Upconversion Detector

    DEFF Research Database (Denmark)

    Barh, Ajanta; Tseng, Yu-Pei; Pedersen, Christian

    2017-01-01

    Inherent limitations in terms of optical losses, selection of nonlinear crystal(s), detection efficiency and pumping conditions in mid-wave (3-5 µm) and long-wave (8-12 µm) infrared frequency upconversion modules are investigated in this paper.......Inherent limitations in terms of optical losses, selection of nonlinear crystal(s), detection efficiency and pumping conditions in mid-wave (3-5 µm) and long-wave (8-12 µm) infrared frequency upconversion modules are investigated in this paper....

  6. Aptamer Based Microsphere Biosensor for Thrombin Detection

    Directory of Open Access Journals (Sweden)

    Xudong Fan

    2006-08-01

    Full Text Available We have developed an optical microsphere resonator biosensor using aptamer asreceptor for the measurement of the important biomolecule thrombin. The sphere surface ismodified with anti-thrombin aptamer, which has excellent binding affinity and selectivityfor thrombin. Binding of the thrombin at the sphere surface is monitored by the spectralposition of the microsphere’s whispering gallery mode resonances. A detection limit on theorder of 1 NIH Unit/mL is demonstrated. Control experiments with non-aptameroligonucleotide and BSA are also carried out to confirm the specific binding betweenaptamer and thrombin. We expect that this demonstration will lead to the development ofhighly sensitive biomarker sensors based on aptamer with lower cost and higher throughputthan current technology.

  7. Minimum Detectable Activity for Tomographic Gamma Scanning System

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Ram [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Smith, Susan [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Kirkpatrick, J. M. [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Croft, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographic Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each “view” is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities

  8. Spatial Outlier Detection of CO2 Monitoring Data Based on Spatial Local Outlier Factor

    Directory of Open Access Journals (Sweden)

    Liu Xin

    2015-12-01

    Full Text Available Spatial local outlier factor (SLOF algorithm was adopted in this study for spatial outlier detection because of the limitations of the traditional static threshold detection. Based on the spatial characteristics of CO2 monitoring data obtained in the carbon capture and storage (CCS project, the K-Nearest Neighbour (KNN graph was constructed using the latitude and longitude information of the monitoring points to identify the spatial neighbourhood of the monitoring points. Then SLOF was adopted to calculate the outlier degrees of the monitoring points and the 3σ rule was employed to identify the spatial outlier. Finally, the selection of K value was analysed and the optimal one was selected. The results show that, compared with the static threshold method, the proposed algorithm has a higher detection precision. It can overcome the shortcomings of the static threshold method and improve the accuracy and diversity of local outlier detection, which provides a reliable reference for the safety assessment and warning of CCS monitoring.

  9. Biotin-Streptavidin Competition Mediates Sensitive Detection of Biomolecules in Enzyme Linked Immunosorbent Assay.

    Science.gov (United States)

    Lakshmipriya, Thangavel; Gopinath, Subash C B; Tang, Thean-Hock

    2016-01-01

    Enzyme Linked Immunosorbent Assay (ELISA) is the gold standard assay for detecting and identifying biomolecules using antibodies as the probe. Improving ELISA is crucial for detecting disease-causing agents and facilitating diagnosis at the early stages of disease. Biotinylated antibody and streptavidin-conjugated horse radish peroxide (streptavidin-HRP) often are used with ELISA to enhance the detection of various kinds of targets. In the present study, we used a competition-based strategy in which we pre-mixed free biotin with streptavidin-HRP to generate high-performance system, as free biotin occupies some of the biotin binding sites on streptavidin, thereby providing more chances for streptavidin-HRP to bind with biotinylated antibody. ESAT-6, which is a protein secreted early during tuberculosis infection, was used as the model target. We found that 8 fM of free biotin mixed with streptavidin-HRP anchored the higher detection level of ESAT-6 by four-fold compared with detection without free biotin (only streptavidin-HRP), and the limit of detection of the new method was 250 pM. These results suggest that biotin-streptavidin competition can be used to improve the diagnosis of analytes in other types of sensors.

  10. Photorespiration and carbon limitation determine productivity in temperate seagrasses.

    Science.gov (United States)

    Buapet, Pimchanok; Rasmusson, Lina M; Gullström, Martin; Björk, Mats

    2013-01-01

    The gross primary productivity of two seagrasses, Zostera marina and Ruppia maritima, and one green macroalga, Ulva intestinalis, was assessed in laboratory and field experiments to determine whether the photorespiratory pathway operates at a substantial level in these macrophytes and to what extent it is enhanced by naturally occurring shifts in dissolved inorganic carbon (DIC) and O2 in dense vegetation. To achieve these conditions in laboratory experiments, seawater was incubated with U. intestinalis in light to obtain a range of higher pH and O2 levels and lower DIC levels. Gross photosynthetic O2 evolution was then measured in this pretreated seawater (pH, 7.8-9.8; high to low DIC:O2 ratio) at both natural and low O2 concentrations (adjusted by N2 bubbling). The presence of photorespiration was indicated by a lower gross O2 evolution rate under natural O2 conditions than when O2 was reduced. In all three macrophytes, gross photosynthetic rates were negatively affected by higher pH and lower DIC. However, while both seagrasses exhibited significant photorespiratory activity at increasing pH values, the macroalga U. intestinalis exhibited no such activity. Rates of seagrass photosynthesis were then assessed in seawater collected from the natural habitats (i.e., shallow bays characterized by high macrophyte cover and by low DIC and high pH during daytime) and compared with open baymouth water conditions (where seawater DIC is in equilibrium with air, normal DIC, and pH). The gross photosynthetic rates of both seagrasses were significantly higher when incubated in the baymouth water, indicating that these grasses can be significantly carbon limited in shallow bays. Photorespiration was also detected in both seagrasses under shallow bay water conditions. Our findings indicate that natural carbon limitations caused by high community photosynthesis can enhance photorespiration and cause a significant decline in seagrass primary production in shallow waters.

  11. Photorespiration and carbon limitation determine productivity in temperate seagrasses.

    Directory of Open Access Journals (Sweden)

    Pimchanok Buapet

    Full Text Available The gross primary productivity of two seagrasses, Zostera marina and Ruppia maritima, and one green macroalga, Ulva intestinalis, was assessed in laboratory and field experiments to determine whether the photorespiratory pathway operates at a substantial level in these macrophytes and to what extent it is enhanced by naturally occurring shifts in dissolved inorganic carbon (DIC and O2 in dense vegetation. To achieve these conditions in laboratory experiments, seawater was incubated with U. intestinalis in light to obtain a range of higher pH and O2 levels and lower DIC levels. Gross photosynthetic O2 evolution was then measured in this pretreated seawater (pH, 7.8-9.8; high to low DIC:O2 ratio at both natural and low O2 concentrations (adjusted by N2 bubbling. The presence of photorespiration was indicated by a lower gross O2 evolution rate under natural O2 conditions than when O2 was reduced. In all three macrophytes, gross photosynthetic rates were negatively affected by higher pH and lower DIC. However, while both seagrasses exhibited significant photorespiratory activity at increasing pH values, the macroalga U. intestinalis exhibited no such activity. Rates of seagrass photosynthesis were then assessed in seawater collected from the natural habitats (i.e., shallow bays characterized by high macrophyte cover and by low DIC and high pH during daytime and compared with open baymouth water conditions (where seawater DIC is in equilibrium with air, normal DIC, and pH. The gross photosynthetic rates of both seagrasses were significantly higher when incubated in the baymouth water, indicating that these grasses can be significantly carbon limited in shallow bays. Photorespiration was also detected in both seagrasses under shallow bay water conditions. Our findings indicate that natural carbon limitations caused by high community photosynthesis can enhance photorespiration and cause a significant decline in seagrass primary production in shallow

  12. Upper limits from counting experiments with multiple pipelines

    International Nuclear Information System (INIS)

    Sutton, Patrick J

    2009-01-01

    In counting experiments, one can set an upper limit on the rate of a Poisson process based on a count of the number of events observed due to the process. In some experiments, one makes several counts of the number of events, using different instruments, different event detection algorithms or observations over multiple time intervals. We demonstrate how to generalize the classical frequentist upper limit calculation to the case where multiple counts of events are made over one or more time intervals using several (not necessarily independent) procedures. We show how different choices of the rank ordering of possible outcomes in the space of counts correspond to applying different levels of significance to the various measurements. We propose an ordering that is matched to the sensitivity of the different measurement procedures and show that in typical cases it gives stronger upper limits than other choices. As an example, we show how this method can be applied to searches for gravitational-wave bursts, where multiple burst-detection algorithms analyse the same data set, and demonstrate how a single combined upper limit can be set on the gravitational-wave burst rate.

  13. Optical detection of ultrasound from optically rough surfaces using a custom CMOS sensor

    International Nuclear Information System (INIS)

    Achamfuo-Yeboah, S O; Light, R A; Sharpies, S D

    2015-01-01

    The optical detection of ultrasound from optically rough surfaces is severely limited when using a conventional interferometric or optical beam deflection (OBD) setup because the detected light is speckled. This means that complicated and expensive setups are required to detect ultrasound optically on rough surfaces. We present a CMOS integrated circuit that can detect laser ultrasound in the presence of speckle. The detector circuit is based on the simple knife edge detector. It is self-adapting and is fast, inxepensive, compact and robust. The CMOS circuit is implemented as a widefield array of 32×32 pixels. At each pixel the received light is compared with an adjacent pixel in order to determine the local light gradient. The result of this comparison is stored and used to connect each pixel to the positive or negative gradient output as appropriate (similar to a balanced knife edge detector). The perturbation of the surface due to ultrasound preserves the speckle distribution whilst deflecting it. The spatial disturbance of the speckle pattern due to the ultrasound is detected by considering each pair of pixels as a knife edge detector. The sensor can adapt itself to match the received optical speckle pattern in less than 0.1 μs, and then detect the ultrasound within 0.5 μs of adaptation. This makes it possible to repeatedly detect ultrasound from optically rough surfaces very quickly. The detector is capable of independent operation controlled by a local microcontroller, or it may be connected to a computer for more sophisticated configuration and control. We present the theory of its operation and discuss results validating the concept and operation of the device. We also present preliminary results from an improved design which grants a higher bandwidth, allowing for optical detection of higher frequency ultrasound

  14. On the gravitational seesaw in higher-derivative gravity

    Energy Technology Data Exchange (ETDEWEB)

    Accioly, Antonio; Giacchini, Breno L. [Centro Brasileiro de Pesquisas Fisicas, Rio de Janeiro, RJ (Brazil); Shapiro, Ilya L. [Universidade Federal de Juiz de Fora, Departamento de Fisica, ICE, Juiz de Fora, MG (Brazil); Tomsk State Pedagogical University, Tomsk (Russian Federation); Tomsk State University, Tomsk (Russian Federation)

    2017-08-15

    Local gravitational theories with more than four derivatives are superrenormalizable. They also may be unitary in the Lee-Wick sense. Thus it is relevant to study the low-energy properties of these theories, especially to identify observables which might be useful for experimental detection of higher derivatives. Using an analogy with the neutrino physics, we explore the possibility of a gravitational seesaw mechanism in which several dimensional parameters of the same order of magnitude produce a hierarchy in the masses of propagating particles. Such a mechanism could make a relatively light degree of freedom detectable in low-energy laboratory and astrophysical observations, such as torsion-balance experiments and the bending of light. We demonstrate that such a seesaw mechanism in the six- and more-derivative theories is unable to reduce the lightest mass more than in the simplest four-derivative model. Adding more derivatives to the four-derivative action of gravity makes heavier masses even greater, while the lightest massive ghost is not strongly affected. This fact is favorable for protecting the theory from instabilities but makes the experimental detection of higher derivatives more difficult. (orig.)

  15. Quarry detection monitoring wells completion report WP-166

    International Nuclear Information System (INIS)

    1991-09-01

    The purpose of this report is to document the activities undertaken during implementation of Work Package 166, Quarry Detection Monitoring Wells, for the Weldon Spring Site Remedial action project, Weldon Spring, Missouri. The subcontract specifications should be consulted for specific details regarding this work effort. Analytical parameters for soil samples collected for all but one borehole were analyzed for uranium, thorium, cyanide, nitroaromatics, and all Hazardous Substance List parameters including volatiles, semivolatiles, pesticides, polychlorinated biphenyls (PCBs) and metals. No soil samples were collected at other borehole as per specifications. With Z exceptions, uranium results for all boreholes sampled were at background levels. Nitroaromatics and cyanide were not detected in any of the samples collected. Volatile and semivolatile organics were not detected in the soil samples collected from the boreholes, with the exception of common lab contaminants such as methylene chloride, toluene, acetone, and pathalates. All metals results were either within their natural background ranges or below the detection limit of the instrument. PCB's were not detected within any of the boreholes. Pesticides detected (aldrin and methoxychlor) at one borehole near the surface may be attributed to previous spraying of pesticides on the highway right-of-way. In conclusion, the analytical results show that only uranium was detected in significant quantities; all other results were below the detection limit, very near the detection limit, or within natural background ranges. 1 fig

  16. Matrix-Matching as an Improvement Strategy for the Detection of Pesticide Residues.

    Science.gov (United States)

    Giacinti, Géraldine; Raynaud, Christine; Capblancq, Sophie; Simon, Valérie

    2016-05-01

    More than 90% of the pesticides residues in apples are located in the peel. We developed a gas chromatography/ion trap tandem mass spectrometry method for investigating all detectable residues in the peel of 3 apple varieties. Sample preparation is based on the use of the Quick Easy Cheap Effective Rugged and Safe method on the whole fruit, the flesh, and the peel. Pesticide residues were quantified with solvent-matched and matrix-matched standards, by spiking apple sample extracts. Matrix effects dependent on the type of extract (fruit, flesh, or peel) and the apple variety were detected. The best data processing methods involved normalizing matrix effect rates by matrix-matched internal/external calibration. Boscalid, captan, chlorpyrifos, fludioxonil, and pyraclostrobin were the most frequently detected pesticides. However, their concentrations in the whole fruit were below European maximum residue levels. Despite negative matrix effects, the residues in peel were detected at concentrations up to 10 times higher than those in whole fruits. Consequently, other pesticide residues present at concentrations below the limit of quantification in the whole fruit were detected in the peel. © 2016 Institute of Food Technologists®

  17. Detection of dechallenge in spontaneous reporting systems: a comparison of Bayes methods.

    Science.gov (United States)

    Banu, A Bazila; Alias Balamurugan, S Appavu; Thirumalaikolundusubramanian, Ponniah

    2014-01-01

    Dechallenge is a response observed for the reduction or disappearance of adverse drug reactions (ADR) on withdrawal of a drug from a patient. Currently available algorithms to detect dechallenge have limitations. Hence, there is a need to compare available new methods. To detect dechallenge in Spontaneous Reporting Systems, data-mining algorithms like Naive Bayes and Improved Naive Bayes were applied for comparing the performance of the algorithms in terms of accuracy and error. Analyzing the factors of dechallenge like outcome and disease category will help medical practitioners and pharmaceutical industries to determine the reasons for dechallenge in order to take essential steps toward drug safety. Adverse drug reactions of the year 2011 and 2012 were downloaded from the United States Food and Drug Administration's database. The outcome of classification algorithms showed that Improved Naive Bayes algorithm outperformed Naive Bayes with accuracy of 90.11% and error of 9.8% in detecting the dechallenge. Detecting dechallenge for unknown samples are essential for proper prescription. To overcome the issues exposed by Naive Bayes algorithm, Improved Naive Bayes algorithm can be used to detect dechallenge in terms of higher accuracy and minimal error.

  18. Derivatizations for improved detection of alcohols by gas chromatography and photoionization detection (GC-PID)

    International Nuclear Information System (INIS)

    Krull, I.S.; Swartz, M.; Driscoll, J.N.

    1984-01-01

    Pentafluorophenyldimethylsilyl chloride (flophemesyl chloride, Fl) is a well known derivatization reagent for improved electron capture detection (ECD) in gas chromatography (GC)(GC-ECD), but it has never been utilized for improved detectability and sensitivity in GC-photoionization detection (GC-PID). A wide variety of flophemesyl alcohol derivatives have been used in order to show a new approach for realizing greatly reduced minimum detection limits (MDL) of virtually all alcohol derivatives in GC-PID analysis. This particular derivatization approach is inexpensive and easy to apply, leading to quantitative or near 100% conversion of the starting alcohols to the expected flophemesyl ethers (silyl ethers). Detection limits can be lowered by 2-3 orders of magnitude for such derivatives when compared with the starting alcohols, along with calibration plots that are linear over 5-7 orders of magnitude. Specific GC conditions have been developed for many flophemesyl derivatives, in all cases using packed columns. Both ECD and PID relative response factors (RRFs) and normalized RRFs have been determined, and such ratios can now be used for improved analytic identification from complex sample matrices, where appropriate. 28 references, 2 figures, 5 tables

  19. Simplified dark matter models with charged mediators: prospects for direct detection

    Energy Technology Data Exchange (ETDEWEB)

    Sandick, Pearl; Sinha, Kuver; Teng, Fei [Department of Physics and Astronomy, University of Utah,Salt Lake City, UT 84112 (United States)

    2016-10-05

    We consider direct detection prospects for a class of simplified models of fermionic dark matter (DM) coupled to left and right-handed Standard Model fermions via two charged scalar mediators with arbitrary mixing angle α. DM interactions with the nucleus are mediated by higher electromagnetic moments, which, for Majorana DM, is the anapole moment. After giving a full analytic calculation of the anapole moment, including its α dependence, and matching with limits in the literature, we compute the DM-nucleon scattering cross-section and show the LUX and future LZ constraints on the parameter space of these models. We then compare these results with constraints coming from Fermi-LAT continuum and line searches. Results in the supersymmetric limit of these simplified models are provided in all cases. We find that future direct detection experiments will be able to probe most of the parameter space of these models for O(100−200) GeV DM and lightest mediator mass ≲O(5%) larger than the DM mass. The direct detection prospects dwindle for larger DM mass and larger mass gap between the DM and the lightest mediator mass, although appreciable regions are still probed for O(200) GeV DM and lightest mediator mass ≲O(20%) larger than the DM mass. The direct detection bounds are also attenuated near certain “blind spots' in the parameter space, where the anapole moment is severely suppressed due to cancellation of different terms. We carefully study these blind spots and the associated Fermi-LAT signals in these regions.

  20. Multiple soft limits of cosmological correlation functions

    International Nuclear Information System (INIS)

    Joyce, Austin; Khoury, Justin; Simonović, Marko

    2015-01-01

    We derive novel identities satisfied by inflationary correlation functions in the limit where two external momenta are taken to be small. We derive these statements in two ways: using background-wave arguments and as Ward identities following from the fixed-time path integral. Interestingly, these identities allow us to constrain some of the O(q 2 ) components of the soft limit, in contrast to their single-soft analogues. We provide several nontrivial checks of our identities both in the context of resonant non-Gaussianities and in small sound speed models. Additionally, we extend the relation at lowest order in external momenta to arbitrarily many soft legs, and comment on the many-soft extension at higher orders in the soft momentum. Finally, we consider how higher soft limits lead to identities satisfied by correlation functions in large-scale structure

  1. Fluorescent QDs-polystyrene composite nanospheres for highly efficient and rapid protein antigen detection

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Changhua; Mao, Mao [Henan University, Key Laboratory for Special Functional Materials of the Ministry of Education (China); Yuan, Hang [Tsinghua University, Life Science Division, Graduate School at Shenzhen (China); Shen, Huaibin [Henan University, Key Laboratory for Special Functional Materials of the Ministry of Education (China); Wu, Feng; Ma, Lan, E-mail: malan@sz.tsinghua.edu.cn [Tsinghua University, Life Science Division, Graduate School at Shenzhen (China); Li, Lin Song, E-mail: lsli@henu.edu.cn [Henan University, Key Laboratory for Special Functional Materials of the Ministry of Education (China)

    2013-09-15

    In this paper, high-quality carboxyl-functionalized fluorescent (red, green, and blue emitting) nanospheres (46-103 nm) consisting of hydrophobic quantum dots (QDs) and polystyrene were prepared by a miniemulsion polymerization approach. This miniemulsion polymerization approach induced a homogeneous distribution and high aqueous-phase transport efficiency of fluorescent QDs in composite nanospheres, which proved the success of our encoding QDs strategy. The obtained fluorescent nanospheres exhibited high stability in aqueous solution under a wide range of pH, different salt concentrations, PBS buffer, and thermal treatment at 80 Degree-Sign C. Based on the red emitting composite nanosphere, we performed fluorescent lateral flow immunoassay (LFIA) strips for high-sensitivity and rapid alpha-fetal protein detection. The detection limit reached 0.1 ng/mL, which was 200 times higher than commercial colloidal gold-labeled LFIA strips, and it reached similar detection level in enzyme-linked immunosorbent assay kit.

  2. Mover Position Detection for PMTLM Based on Linear Hall Sensors through EKF Processing.

    Science.gov (United States)

    Yan, Leyang; Zhang, Hui; Ye, Peiqing

    2017-04-06

    Accurate mover position is vital for a permanent magnet tubular linear motor (PMTLM) control system. In this paper, two linear Hall sensors are utilized to detect the mover position. However, Hall sensor signals contain third-order harmonics, creating errors in mover position detection. To filter out the third-order harmonics, a signal processing method based on the extended Kalman filter (EKF) is presented. The limitation of conventional processing method is first analyzed, and then EKF is adopted to detect the mover position. In the EKF model, the amplitude of the fundamental component and the percentage of the harmonic component are taken as state variables, and they can be estimated based solely on the measured sensor signals. Then, the harmonic component can be calculated and eliminated. The proposed method has the advantages of faster convergence, better stability and higher accuracy. Finally, experimental results validate the effectiveness and superiority of the proposed method.

  3. Memory detection 2.0: the first web-based memory detection test.

    Science.gov (United States)

    Kleinberg, Bennett; Verschuere, Bruno

    2015-01-01

    There is accumulating evidence that reaction times (RTs) can be used to detect recognition of critical (e.g., crime) information. A limitation of this research base is its reliance upon small samples (average n = 24), and indications of publication bias. To advance RT-based memory detection, we report upon the development of the first web-based memory detection test. Participants in this research (Study1: n = 255; Study2: n = 262) tried to hide 2 high salient (birthday, country of origin) and 2 low salient (favourite colour, favourite animal) autobiographical details. RTs allowed to detect concealed autobiographical information, and this, as predicted, more successfully so than error rates, and for high salient than for low salient items. While much remains to be learned, memory detection 2.0 seems to offer an interesting new platform to efficiently and validly conduct RT-based memory detection research.

  4. Memory detection 2.0: the first web-based memory detection test.

    Directory of Open Access Journals (Sweden)

    Bennett Kleinberg

    Full Text Available There is accumulating evidence that reaction times (RTs can be used to detect recognition of critical (e.g., crime information. A limitation of this research base is its reliance upon small samples (average n = 24, and indications of publication bias. To advance RT-based memory detection, we report upon the development of the first web-based memory detection test. Participants in this research (Study1: n = 255; Study2: n = 262 tried to hide 2 high salient (birthday, country of origin and 2 low salient (favourite colour, favourite animal autobiographical details. RTs allowed to detect concealed autobiographical information, and this, as predicted, more successfully so than error rates, and for high salient than for low salient items. While much remains to be learned, memory detection 2.0 seems to offer an interesting new platform to efficiently and validly conduct RT-based memory detection research.

  5. Epigenetics of drought-induced trans-generational plasticity: consequences for range limit development

    Science.gov (United States)

    Alsdurf, Jacob; Anderson, Cynthia; Siemens, David H.

    2016-01-01

    Genetic variation gives plants the potential to adapt to stressful environments that often exist beyond their geographic range limits. However, various genetic, physiological or developmental constraints might prevent the process of adaptation. Alternatively, environmentally induced epigenetic changes might sustain populations for several generations in stressful areas across range boundaries, but previous work on Boechera stricta, an upland mustard closely related to Arabidopsis, documented a drought-induced trans-generational plastic trade-off that could contribute to range limit development. Offspring of parents who were drought treated had higher drought tolerance, but lower levels of glucosinolate toxins. Both drought tolerance and defence are thought to be needed to expand the range to lower elevations. Here, we used methylation-sensitive amplified fragment length polymorphisms to determine whether environmentally induced DNA methylation and thus epigenetics could be a mechanism involved in the observed trans-generational plastic trade-off. We compared 110 offspring from the same self-fertilizing lineages whose parents were exposed to experimental drought stress treatments in the laboratory. Using three primer combinations, 643 polymorphic epi-loci were detected. Discriminant function analysis (DFA) on the amount of methylation detected resulted in significant combinations of epi-loci that distinguished the parent drought treatments in the offspring. Principal component (PC) and univariate association analyses also detected the significant differences, even after controlling for lineage, planting flat, developmental differences and multiple testing. Univariate tests also indicated significant associations between the amount of methylation and drought tolerance or glucosinolate toxin concentration. One epi-locus that was implicated in DFA, PC and univariate association analysis may be directly involved in the trade-off because increased methylation at this

  6. Epigenetics of drought-induced trans-generational plasticity: consequences for range limit development.

    Science.gov (United States)

    Alsdurf, Jacob; Anderson, Cynthia; Siemens, David H

    2015-12-18

    Genetic variation gives plants the potential to adapt to stressful environments that often exist beyond their geographic range limits. However, various genetic, physiological or developmental constraints might prevent the process of adaptation. Alternatively, environmentally induced epigenetic changes might sustain populations for several generations in stressful areas across range boundaries, but previous work on Boechera stricta, an upland mustard closely related to Arabidopsis, documented a drought-induced trans-generational plastic trade-off that could contribute to range limit development. Offspring of parents who were drought treated had higher drought tolerance, but lower levels of glucosinolate toxins. Both drought tolerance and defence are thought to be needed to expand the range to lower elevations. Here, we used methylation-sensitive amplified fragment length polymorphisms to determine whether environmentally induced DNA methylation and thus epigenetics could be a mechanism involved in the observed trans-generational plastic trade-off. We compared 110 offspring from the same self-fertilizing lineages whose parents were exposed to experimental drought stress treatments in the laboratory. Using three primer combinations, 643 polymorphic epi-loci were detected. Discriminant function analysis (DFA) on the amount of methylation detected resulted in significant combinations of epi-loci that distinguished the parent drought treatments in the offspring. Principal component (PC) and univariate association analyses also detected the significant differences, even after controlling for lineage, planting flat, developmental differences and multiple testing. Univariate tests also indicated significant associations between the amount of methylation and drought tolerance or glucosinolate toxin concentration. One epi-locus that was implicated in DFA, PC and univariate association analysis may be directly involved in the trade-off because increased methylation at this

  7. Conformal bootstrap with slightly broken higher spin symmetry

    Energy Technology Data Exchange (ETDEWEB)

    Alday, Luis F. [Mathematical Institute, University of Oxford,Andrew Wiles Building, Radcliffe Observatory Quarter,Woodstock Road, Oxford, OX2 6GG (United Kingdom); Zhiboedov, Alexander [Center for the Fundamental Laws of Nature,Harvard University, Cambridge, MA 02138 (United States)

    2016-06-16

    We consider conformal field theories with slightly broken higher spin symmetry in arbitrary spacetime dimensions. We analyze the crossing equation in the double light-cone limit and solve for the anomalous dimensions of higher spin currents γ{sub s} with large spin s. The result depends on the symmetries and the spectrum of the unperturbed conformal field theory. We reproduce all known results and make further predictions. In particular we make a prediction for the anomalous dimensions of higher spin currents in the 3d Ising model.

  8. Validity and limitations of the Nidek NT-4000 non-contact tonometer: a clinical study.

    Science.gov (United States)

    Regine, Federico; Scuderi, Gian Luca; Cesareo, Massimo; Ricci, Federico; Cedrone, Claudio; Nucci, Carlo

    2006-01-01

    Using Goldmann applanation tonometry (GAT) as a gold standard, we evaluated the accuracy of Nidek NT-4000 pneumotonometry (NPT) in adults without corneal disease. Bland and Altman analysis of serial intra-ocular pressures (IOPs) measured with NPT and GAT in 10 healthy subjects revealed that the repeatability coefficients for the two methods were similar. NPT, GAT and ultrasonic pachymetry were then performed in 100 patients. Bland and Altman analysis showed that NPT yielded significantly higher readings than GAT [mean biases for right and left eye measurements were 1.37 mmHg (95% limits of agreement: -3.02-5.76) and 1.17 mmHg (95% limits of agreement: -2.76-5.11) respectively] and was more affected by corneal thickness variations. For detection of IOPs > or =21 mmHg, NPT displayed very high sensitivity (0.90) and good specificity (0.95). NPT may be useful in screening and clinical settings but borderline-high IOP readings should be confirmed with GAT.

  9. Physicochemical properties determining the detection probability of tryptic peptides in Fourier transform mass spectrometry. A correlation study

    DEFF Research Database (Denmark)

    Nielsen, Michael L; Savitski, Mikhail M; Kjeldsen, Frank

    2004-01-01

    Sequence verification and mapping of posttranslational modifications require nearly 100% sequence coverage in the "bottom-up" protein analysis. Even in favorable cases, routine liquid chromatography-mass spectrometry detects from protein digests peptides covering 50-90% of the sequence. Here we...... investigated the reasons for limited peptide detection, considering various physicochemical aspects of peptide behavior in liquid chromatography-Fourier transform mass spectrometry (LC-FTMS). No overall correlation was found between the detection probability and peptide mass. In agreement with literature data...... between pI and signal response. An explanation of this paradoxal behavior was found through the observation that more acidic tryptic peptide lengths tend to be longer. Longer peptides tend to acquire higher average charge state in positive mode electrospray ionization than more basic but shorter...

  10. Method of detecting a failed fuel

    International Nuclear Information System (INIS)

    Utamura, Motoaki; Urata, Megumi; Uchida, Shunsuke.

    1976-01-01

    Object: To improve detection accuracy of a failed fuel by eliminating a coolant temperature distribution in a fuel assembly. Structure: A failed fuel is detected from contents of nuclear fission products in a coolant by shutting off an upper portion of a fuel assembly provided in the coolant and by sampling the coolant in the fuel assembly. Temperature distribution in the fuel assembly is eliminated, by injecting the higher temperature coolant than that of the coolant inside and outside the fuel assembly when sampling, and thereby replacing the existing coolant in the fuel assembly for the higher temperature coolant. The failed fuel is detected from contents of the fission products existing in the coolant, by sampling the higher temperature coolant of the fuel assembly after a temperature passed. (Moriyama, K.)

  11. Invariant functionals in higher-spin theory

    Directory of Open Access Journals (Sweden)

    M.A. Vasiliev

    2017-03-01

    Full Text Available A new construction for gauge invariant functionals in the nonlinear higher-spin theory is proposed. Being supported by differential forms closed by virtue of the higher-spin equations, invariant functionals are associated with central elements of the higher-spin algebra. In the on-shell AdS4 higher-spin theory we identify a four-form conjectured to represent the generating functional for 3d boundary correlators and a two-form argued to support charges for black hole solutions. Two actions for 3d boundary conformal higher-spin theory are associated with the two parity-invariant higher-spin models in AdS4. The peculiarity of the spinorial formulation of the on-shell AdS3 higher-spin theory, where the invariant functional is supported by a two-form, is conjectured to be related to the holomorphic factorization at the boundary. The nonlinear part of the star-product function F⁎(B(x in the higher-spin equations is argued to lead to divergencies in the boundary limit representing singularities at coinciding boundary space–time points of the factors of B(x, which can be regularized by the point splitting. An interpretation of the RG flow in terms of proposed construction is briefly discussed.

  12. One-step synthesis of Ag@PANI nanocomposites and their application to detection of mercury

    International Nuclear Information System (INIS)

    Wang, Xiufang; Shen, Yuhua; Xie, Anjian; Chen, Shaohua

    2013-01-01

    The Ag@Polyaniline (PANI) core–shell nanoparticles were successfully synthesized by one-step radiation of sunlight method using silver nitrate as the oxidant for aniline without any additives or templates. The Ag@PANI core–shell nanocomposites were used as active surface enhanced Raman scattering (SERS) nanoprobes for the detection of some heavy metal ions, such as Pb 2+ , Cu 2+ Hg 2+ , Cd 2+ , and so on, which is based upon the Raman intensity response of PANI to metal ions. It turns out that the nanoprobes represent a rather high selectivity for Hg 2+ detection. It is also important that the detection limit of Hg 2+ concentration is ca. 1 × 10 −12 M in this system, due to the great sensitivity of SERS nanoprobes. The developed nanoprobes could have potential applications in highly sensitive chemical, environmental and biological analysis, as well as medical detection. - Highlights: • The Ag@PANI nanocomposites are fabricated by a simple synthetic route. • Nanocomposites are utilized directly as SERS nanosensors without being additionally functionalized. • Higher selectivity and ultrasensitive sensitivity for Hg 2+ ions detection

  13. Detection methods for legionellae. Possibilities and limitations of detection methods; Niet alle detectiemethoden geschikt voor legionellagroei. Mogelijkheden en beperkingen detectiemethoden

    Energy Technology Data Exchange (ETDEWEB)

    Scheffer, W.

    2011-06-15

    This article provides an overview of existing and new methods for detecting legionella in water. It offers insight in the characteristics and applications of existing and new detection methods. However, it is impossible to assess the value of alternative methods at the moment. That will require additional research. [Dutch] Een overzicht is gemaakt van bestaande en nieuwe methoden om legionella in water aan te tonen. Daarmee wordt inzicht verkregen in de kenmerken en toepassingsmogelijkheden van bestaande en nieuwe detectiemethoden. De waarde van alternatieve methoden in een installatie kan echter nog niet worden beoordeeld. Daarvoor is nader onderzoek nodig.

  14. Evaluation of high yielding soybean germplasm under water limitation.

    Science.gov (United States)

    Prince, Silvas J; Murphy, Mackensie; Mutava, Raymond N; Zhang, Zhengzhi; Nguyen, Na; Kim, Yoon Ha; Pathan, Safiullah M; Shannon, Grover J; Valliyodan, Babu; Nguyen, Henry T

    2016-05-01

    Limited information is available for soybean root traits and their plasticity under drought stress. To date, no studies have focused on examining diverse soybean germplasm for regulation of shoot and root response under water limited conditions across varying soil types. In this study, 17 genetically diverse soybean germplasm lines were selected to study root response to water limited conditions in clay (trial 1) and sandy soil (trial 2) in two target environments. Physiological data on shoot traits was measured at multiple crop stages ranging from early vegetative to pod filling. The phenotypic root traits, and biomass accumulation data are collected at pod filling stage. In trial 1, the number of lateral roots and forks were positively correlated with plot yield under water limitation and in trial 2, lateral root thickness was positively correlated with the hill plot yield. Plant Introduction (PI) 578477A and 088444 were found to have higher later root number and forks in clay soil with higher yield under water limitation. In sandy soil, PI458020 was found to have a thicker lateral root system and higher yield under water limitation. The genotypes identified in this study could be used to enhance drought tolerance of elite soybean cultivars through improved root traits specific to target environments. © 2015 Institute of Botany, Chinese Academy of Sciences.

  15. Quality assurance of nuclear analytical techniques based on Bayesian characteristic limits

    International Nuclear Information System (INIS)

    Michel, R.

    2000-01-01

    Based on Bayesian statistics, characteristic limits such as decision threshold, detection limit and confidence limits can be calculated taking into account all sources of experimental uncertainties. This approach separates the complete evaluation of a measurement according to the ISO Guide to the Expression of Uncertainty in Measurement from the determination of the characteristic limits. Using the principle of maximum entropy the characteristic limits are determined from the complete standard uncertainty of the measurand. (author)

  16. Detection circuit for gamma-ray burst

    International Nuclear Information System (INIS)

    Murakami, Hiroyuki; Yamagami, Takamasa; Mori, Kunishiro; Uchiyama, Sadayuki.

    1982-01-01

    A new gamma-ray burst detection system is described. The system was developed as an environmental monitor of an accelerator, and can be used as the burst detection system. The system detects the arrival time of burst. The difference between the arrival times detected at different places will give information on the burst source. The frequency of detecting false burst was estimated, and the detection limit under the estimated frequency of false burst was also calculated. Decision whether the signal is false or true burst was made by the statistical treatment. (Kato, T.)

  17. Detection of the circulating antigen 14-3-3 protein of Schistosoma japonicum by time-resolved fluoroimmunoassay in rabbits

    Directory of Open Access Journals (Sweden)

    Wang Jie

    2011-05-01

    Full Text Available Abstract Background Schistosomiasis remains a major public health concern that afflicts millions of people worldwide. Low levels of Schistosoma infection require more sensitive diagnostic methods. In this study, a time-resolved fluoroimmunoassay (TRFIA was developed for detecting the signal transduction protein 14-3-3, a circulating antigen of Schistosoma japonicum. Results The detection limit of 14-3-3-TRFIA was 0.78 ng/ml, with a linear measurement range from 0.78 to 800 ng/ml. The average intra-assay and inter-assay variability of this TRFIA was 8.9% and 12.2% respectively, and the mean recovery rate ranged from 92.1% to 115.5%. Within the first 21 days post-infection in rabbits, the positive rates of the 14-3-3-TRFIA were distinctly higher compared to ELISA. All these findings illustrate that 14-3-3-TRFIA has a higher detection efficacy and is a good early diagnostic method for active Schistosoma infection. Conclusions A sandwich TRFIA for detecting the circulating antigen 14-3-3 of S. japonicum has been developed, and has demonstrated to be a good potential diagnostic method for schistosomiasis.

  18. Detection of dopamine neurotransmission in 'real time'

    Directory of Open Access Journals (Sweden)

    Rajendra D Badgaiyan

    2013-07-01

    Full Text Available Current imaging techniques have limited ability to detect neurotransmitters released during brain processing. It is a critical limitation because neurotransmitters have significant control over the brain activity. In this context, recent development of single-scan dynamic molecular imaging technique is important because it allows detection, mapping, and measurement of dopamine released in the brain during task performance. The technique exploits the competition between endogenously released dopamine and its receptor ligand for occupancy of receptor sites. Dopamine released during task performance is detected by dynamically measuring concentration of intravenously injected radiolabeled ligand using a positron emission tomography camera. Based on the ligand concentration, values of receptor kinetic parameters are estimated. These estimates allow detection of dopamine released in the human brain during task performance.

  19. Spreadsheet design and validation for characteristic limits determination in gross alpha and beta measurement

    International Nuclear Information System (INIS)

    Prado, Rodrigo G.P. do; Dalmazio, Ilza

    2013-01-01

    The identification and detection of ionizing radiation are essential requisites of radiation protection. Gross alpha and beta measurements are widely applied as a screening method in radiological characterization, environmental monitoring and industrial applications. As in any other analytical technique, test performance depends on the quality of instrumental measurements and reliability of calculations. Characteristic limits refer to three specific statistics, namely, decision threshold, detection limit and confidence interval, which are fundamental to ensuring the quality of determinations. This work describes a way to calculate characteristic limits for measurements of gross alpha and beta activity applying spreadsheets. The approach used for determination of decision threshold, detection limit and limits of the confidence interval, the mathematical expressions of measurands and uncertainty followed standards guidelines. A succinct overview of this approach and examples are presented and spreadsheets were validated using specific software. Furthermore, these spreadsheets could be used as tool to instruct beginner users of methods for ionizing radiation measurements. (author)

  20. System for detecting and limiting electrical ground faults within electrical devices

    International Nuclear Information System (INIS)

    Gaubatz, D.C.

    1990-01-01

    This paper discusses, in a nuclear power plant of a variety wherein a reactor is provided including a reactor vessel retaining a liquid metal coolant, a reactor core and an electromagnetic pump having inductive windings insulatively retained within the electrically conductive wall of an enclosure, the method for controlling electrical ground fault current between a the inductive winding and the walls. It comprises providing an electrically isolated power source by inductive coupling with the plant power supply; rectifying the power source to provide an isolated d.c. power source; providing an inverter powered from the isolated d.c. power source under the control of the plant control system for selectively energizing the inductive windings; providing a fault control conductor electrically connected with the pump enclosure wall and extending as an electrical return for ground fault current to the inverter; and providing an electrical resistance between the conductor and the isolated inverter having an impedance selected to limit the fault current below a predetermined value limiting arc damage at any the electrical ground fault location

  1. Physiological Limits along an Elevational Gradient in a Radiation of Montane Ground Beetles.

    Science.gov (United States)

    Slatyer, Rachel A; Schoville, Sean D

    2016-01-01

    A central challenge in ecology and biogeography is to determine the extent to which physiological constraints govern the geographic ranges of species along environmental gradients. This study tests the hypothesis that temperature and desiccation tolerance are associated with the elevational ranges of 12 ground beetle species (genus Nebria) occurring on Mt. Rainier, Washington, U.S.A. Species from higher elevations did not have greater cold tolerance limits than lower-elevation species (all species ranged from -3.5 to -4.1°C), despite a steep decline in minimum temperature with elevation. Although heat tolerance limits varied among species (from 32.0 to 37.0°C), this variation was not generally associated with the relative elevational range of a species. Temperature gradients and acute thermal tolerance do not support the hypothesis that physiological constraints drive species turnover with elevation. Measurements of intraspecific variation in thermal tolerance limits were not significant for individuals taken at different elevations on Mt. Rainier, or from other mountains in Washington and Oregon. Desiccation resistance was also not associated with a species' elevational distribution. Our combined results contrast with previously-detected latitudinal gradients in acute physiological limits among insects and suggest that other processes such as chronic thermal stress or biotic interactions might be more important in constraining elevational distributions in this system.

  2. Development of Loop-Mediated Isothermal Amplification for Detection of Leifsonia xyli subsp. xyli in Sugarcane

    Directory of Open Access Journals (Sweden)

    Jing Liu

    2013-01-01

    Full Text Available Ratoon stunt, caused by the xylem-limited coryneform bacterium Leifsonia xyli subsp. xyli (Lxx, is a deep bacteriosis and prevalent in most of sugarcane-producing countries. Based on loop-mediated isothermal amplification (LAMP, we developed a method for detecting Lxx. The major advantages of the LAMP method are visual judgment by color and time saving with only 60 min for identification of Lxx and without the need for costly PCR apparatus and gel scanner. In the present study, positive and negative samples detected by the LAMP method were clearly distinguishable. When total DNA extracted from internode juice was used as the template, the sensitivity of LAMP was 10 times higher than that of the conventional PCR detection. The LAMP assay is a highly specific, rapid, and sensitive method for the diagnosis of ratoon stunt caused by Lxx in sugarcane. This is the first report of LAMP-based assay for the detection of Lxx in sugarcane.

  3. Higher spin gauge theory on fuzzy \\boldsymbol {S^4_N}

    Science.gov (United States)

    Sperling, Marcus; Steinacker, Harold C.

    2018-02-01

    We examine in detail the higher spin fields which arise on the basic fuzzy sphere S^4N in the semi-classical limit. The space of functions can be identified with functions on classical S 4 taking values in a higher spin algebra associated to \

  4. Long-term follow-up of the TIPS early detection in psychosis study

    DEFF Research Database (Denmark)

    Simonsen, Erik; Hegelstad, Wenche ten Welden; Larsen, Tor Ketil

    2012-01-01

    ill patients dropping out of the study in the usual-detection area. Except for higher levels of excitative symptoms in the early-detection area, there were no symptom differences between the groups. Early-detection recovery rates were higher largely because of higher employment rates for patients...

  5. Asymptotic Expansions for Higher-Order Scalar Difference Equations

    Directory of Open Access Journals (Sweden)

    Pituk Mihály

    2007-01-01

    Full Text Available We give an asymptotic expansion of the solutions of higher-order Poincaré difference equation in terms of the characteristic solutions of the limiting equation. As a consequence, we obtain an asymptotic description of the solutions approaching a hyperbolic equilibrium of a higher-order nonlinear difference equation with sufficiently smooth nonlinearity. The proof is based on the inversion formula for the z -transform and the residue theorem.

  6. An improved electrochemiluminescence polymerase chain reaction method for highly sensitive detection of plant viruses

    International Nuclear Information System (INIS)

    Tang Yabing; Xing Da; Zhu Debin; Liu Jinfeng

    2007-01-01

    Recently, we have reported an electrochemiluminescence polymerase chain reaction (ECL-PCR) method for detection of genetically modified organisms. The ECL-PCR method was further improved in the current study by introducing a multi-purpose nucleic acid sequence that was specific to the tris(bipyridine) ruthenium (TBR) labeled probe, into the 5' terminal of the primers. The method was applied to detect plant viruses. Conserved sequence of the plant viruses was amplified by PCR. The product was hybridized with a biotin labeled probe and a TBR labeled probe. The hybridization product was separated by streptavidin-coated magnetic beads, and detected by measuring the ECL signals of the TBR labeled. Under the optimized conditions, the experiment results show that the detection limit is 50 fmol of PCR products, and the signal-to-noise ratio is in excess of 14.6. The method was used to detect banana streak virus, banana bunchy top virus, and papaya leaf curl virus. The experiment results show that this method could reliably identity viruses infected plant samples. The improved ECL-PCR approach has higher sensitivity and lower cost than previous approach. It can effectively detect the plant viruses with simplicity, stability, and high sensitivity

  7. Higher than expected NOx emission from trucks may affect attainability of NO2 limit values in the Netherlands

    NARCIS (Netherlands)

    Velders, G.J.M.; Geilenkirchen, G.P.; Lange, R. de

    2011-01-01

    In past years, the European limit value for average annual NO2 concentration has been exceeded in city streets and along motorways in the Netherlands. By 2015 the limit value must be adhered to in the Netherlands. Although the total road length for which exceedance is likely is expected to decrease

  8. Integrated Circuits for Rapid Sample Processing and Electrochemical Detection of Biomarkers

    Science.gov (United States)

    Besant, Justin

    The trade-off between speed and sensitivity of detection is a fundamental challenge in the design of point-of-care diagnostics. As the relevant molecules in many diseases exist natively at extremely low levels, many gold-standard diagnostic tests are designed with high sensitivity at the expense of long incubations needed to amplify the target analytes. The central aim of this thesis is to design new strategies to detect biologically relevant analytes with both high speed and sensitivity. The response time of a biosensor is limited by the ability of the target analyte to accumulate to detectable levels at the sensor surface. We overcome this limitation by designing a range of integrated devices to optimize the flux of the analyte to the sensor by increasing the effective analyte concentration, shortening the required diffusion distance, and confining the analyte in close proximity to the sensor. We couple these devices with novel ultrasensitive electrochemical transduction strategies to convert rare analytes into a detectable signal. We showcase the clinical utility of these approaches with several applications including cancer diagnosis, bacterial identification, and antibiotic susceptibility profiling. We design and optimize a device to isolate rare cancer cells from the bloodstream with near 100% efficiency and 10 000-fold specificity. We analyse pathogen specific nucleic acids by lysing bacteria in close proximity to an electrochemical sensor and find that this approach has 10-fold higher sensitivity than standard lysis in bulk solution. We design an electronic chip to readout the antibiotic susceptibility profile with an hour-long incubation by concentrating bacteria into nanoliter chambers with integrated electrodes. Finally, we report a strategy for ultrasensitive visual readout of nucleic acids as low as 100 fM within 10 minutes using an amplification cascade. The strategies presented could guide the development of fast, sensitive and low-cost diagnostics

  9. Direct immobilization of antibodies on Zn-doped Fe{sub 3}O{sub 4} nanoclusters for detection of pathogenic bacteria

    Energy Technology Data Exchange (ETDEWEB)

    Pal, Monalisa; Lee, Sanghee; Kwon, Donghoon; Hwang, Jeongin; Lee, Hyeonjeong; Hwang, Seokyung; Jeon, Sangmin, E-mail: jeons@postech.ac.kr

    2017-02-01

    Zinc-doped magnetic nanoclusters (Zn-MNCs) were synthesized and used to detect pathogenic bacteria in milk. Hydrothermally synthesized Zn-MNCs exhibited stronger magnetic properties than pure MNCs, which facilitated the magnetic separation from the sample using a permanent magnet. The presence of accessible Zn sites allows the direct immobilization of half-fragmented antibodies over Zn-MNCs through strong Zn−S bonds and prevents the tedious multiple steps of molecular functionalization or coating with costly noble metals prior to conjugation with an antibody. After the capture and magnetic separation of Salmonella in milk using the antibody-functionalized Zn-MNCs, the concentration of bacteria was determined with a portable ATP luminometer and the detection limit was found to be 10 CFU/mL. - Highlights: • Zn-doped Fe{sub 3}O{sub 4} nanoclusters (Zn-MNCs) were synthesized by hydrothermal method. • Antibodies were directly immobilized over Zn-MNCs through strong Zn–S{sub thiol} bonds. • Higher magnetization of Zn-MNCs than pure MNCs facilitates the magnetic separation. • Detection limit of pathogenic bacteria in milk was found to be 10 cfu/mL. • Cost effective, sensitive and selective detection of bacteria.

  10. Higher-spin algebras, holography and flat space

    Energy Technology Data Exchange (ETDEWEB)

    Sleight, C. [Max-Planck-Institut für Physik (Werner-Heisenberg-Institut),Föhringer Ring 6, D-80805 Munich (Germany); Université Libre de Bruxelles and International Solvay Institutes,ULB-Campus Plaine CP231, 1050 Brussels (Belgium); Taronna, M. [Université Libre de Bruxelles and International Solvay Institutes,ULB-Campus Plaine CP231, 1050 Brussels (Belgium)

    2017-02-20

    In this article we study the higher-spin algebra behind the type-A cubic couplings recently extracted from the free O(N) model in generic dimensions, demonstrating that they coincide with the known structure constants for the unique higher-spin algebra in generic dimensions. This provides an explicit check of the holographic reconstruction and of the duality between higher-spin theories and the free O(N) model in generic dimensions, generalising the result of Giombi and Yin in AdS{sub 4}. For completeness, we also address the same problem in the flat space for the cubic couplings derived by Metsaev in 1991, which are recovered from the flat limit of the AdS type-A cubic couplings. We observe that both flat and AdS{sub 4} higher-spin Lorentz subalgebras coincide, hinting towards the existence of a full higher-spin symmetry behind the flat-space cubic couplings of Metsaev.

  11. Improving cyberbullying detection with user context

    NARCIS (Netherlands)

    Dadvar, M.; Trieschnigg, Rudolf Berend; Ordelman, Roeland J.F.; de Jong, Franciska M.G.

    The negative consequences of cyberbullying are becoming more alarming every day and technical solutions that allow for taking appropriate action by means of automated detection are still very limited. Up until now, studies on cyberbullying detection have focused on individual comments only,

  12. Microcystin Detection Characteristics of Fluorescence Immunochromatography and High Performance Liquid Chromatography

    International Nuclear Information System (INIS)

    Pyo, Dong Jin; Park, Geun Young; Choi, Jong Chon; Oh, Chang Suk

    2005-01-01

    Different detection characteristics of fluorescence immunochromatography method and high performance liquid chromatography (HPLC) method for the analysis of cyanobacterial toxins were studied. In particular, low and high limits of detection, detection time and reproducibility and detectable microcystin species were compared when fluorescence immunochromatography method and high performance liquid chromatography method were applied for the detection of microcystin (MC), a cyclic peptide toxin of the freshwater cyanobacterium Microcystis aeruginosa. A Fluorescence immunochromatography assay system has the unique advantages of short detection time and low detection limit, and high performance liquid chromatography detection method has the strong advantage of individual quantifications of several species of microcystins

  13. Detection of actinides and rare earths in natural matrices with the AGLAE new, high sensitivity detection set-up

    Science.gov (United States)

    Zucchiatti, Alessandro; Alonso, Ursula; Lemasson, Quentin; Missana, Tiziana; Moignard, Brice; Pacheco, Claire; Pichon, Laurent; Camarena de la Mora, Sandra

    2014-08-01

    A series of granite samples (Grimsel and Äspö) enriched by sorption with natU (10-3 M, 10-4 M, 10-5 M in solution) and La (10-3 M, 10-4 M in solution) has been scanned by PIXE over a surface of 1920 × 1920 mm2 together with non-enriched Grimsel and Äspö granites and a glass standard. An assessment of minimum detection limits, MDL's, for several elements has been performed with the use of standard materials. Due to mapping and the high sensitivity of the new AGLAE detection system, U levels around 30 ppm can be detected from the whole PIXE spectrum (one low energy detector and four summed filtered detectors) while U reach grains, inhomogeneously distributed over the surface can be clearly identified through the multi elemental maps and analyzed separately. Even the nominally enriched samples have La levels below the MDL, probably because precipitation of the element (and not adsorption) mostly took place, and precipitates were eliminated after surface cleaning carried out before PIXE analyses. A multi detector system that implies a PIXE detection solid angle much wider than in any other similar set-up (a factor of 2-5); a higher events selectivity, given by the possibility of filtering individually up to 4 PIXE detectors; a double RBS detector, the new Ion Beam Induced Luminescence (IBIL) spectrometry and gamma spectrometry. Full mapping capability in air, assisted by a powerful event by event reconstruction software. These features allow lower Minimum Detection Limits (MDL) which are highly beneficial to the analysis of cultural heritage objects, meaning generally a reduction of irradiation time. Paintings will then be studied without any damage to the pigments that have color change tendencies which is a major drawback of the previous system. Alternatively they could allow an increase in information collected at equal time, particularly considering the detector's fast response and therefore the potential for high beam currents when sample damage can be

  14. Effects of capacity limits, memory loss, and sound type in change deafness.

    Science.gov (United States)

    Gregg, Melissa K; Irsik, Vanessa C; Snyder, Joel S

    2017-11-01

    Change deafness, the inability to notice changes to auditory scenes, has the potential to provide insights about sound perception in busy situations typical of everyday life. We determined the extent to which change deafness to sounds is due to the capacity of processing multiple sounds and the loss of memory for sounds over time. We also determined whether these processing limitations work differently for varying types of sounds within a scene. Auditory scenes composed of naturalistic sounds, spectrally dynamic unrecognizable sounds, tones, and noise rhythms were presented in a change-detection task. On each trial, two scenes were presented that were same or different. We manipulated the number of sounds within each scene to measure memory capacity and the silent interval between scenes to measure memory loss. For all sounds, change detection was worse as scene size increased, demonstrating the importance of capacity limits. Change detection to the natural sounds did not deteriorate much as the interval between scenes increased up to 2,000 ms, but it did deteriorate substantially with longer intervals. For artificial sounds, in contrast, change-detection performance suffered even for very short intervals. The results suggest that change detection is generally limited by capacity, regardless of sound type, but that auditory memory is more enduring for sounds with naturalistic acoustic structures.

  15. [Role of MRI for detection and characterization of pulmonary nodules].

    Science.gov (United States)

    Sommer, G; Koenigkam-Santos, M; Biederer, J; Puderbach, M

    2014-05-01

    Due to physical and technical limitations, magnetic resonance imaging (MRI) has hitherto played only a minor role in image-based diagnostics of the lungs. However, as a consequence of important methodological developments during recent years, MRI has developed into a technically mature and clinically well-proven method for specific pulmonary questions. The purpose of this article is to provide an overview on the currently available sequences and techniques for assessment of pulmonary nodules and analyzes the clinical significance according to the current literature. The main focus is on the detection of lung metastases, the detection of primary pulmonary malignancies in high-risk individuals and the differentiation between pulmonary nodules of benign and malignant character. The MRI technique has a sensitivity of approximately 80 % for detection of malignant pulmonary nodules compared to the reference standard low-dose computed tomography (CT) and is thus somewhat inferior to CT. Advantages of MRI on the other hand are a higher specificity in differentiating malignant and benign pulmonary nodules and the absence of ionizing radiation exposure. A systematic use of MRI as a primary tool for detection and characterization of pulmonary nodules is currently not recommended due to insufficient data. The diagnostic potential of MRI for early detection and staging of malignant pulmonary diseases, however, seems promising. Therefore, further evaluation of MRI as a secondary imaging modality in clinical trials is highly warranted.

  16. Improved limits and portability over currently employed cadmium monitoring systems through preconcentration for detection by way of micro-/nanofluidic mechanisms

    Science.gov (United States)

    Wach, Paul

    concentrate Cd at an initial concentration of 0.5 mol/m3, which is nearly half the limit of commercially available technology. Additionally, this preconcentration mechanism was demonstrated to potentially advance its capabilities by attaching channels in series or parallel to further preconcentrate for improved detection. Finally, measurement of extremely low concentrations of Cd is possible due to differences seen in the concentration distribution profiles once steady-state is reached.

  17. Levels of cyclic-2,3-diphosphoglycerate in Methanobacterium thermoautotrophicum during phosphate limitation.

    OpenAIRE

    Seely, R J; Fahrney, D E

    1984-01-01

    Batch-grown Methanobacterium thermoautotrophicum cells grew nonexponentially in the absence of exogenous Pi until intracellular cyclic-2,3-diphosphoglycerate (cyclic DPG) had fallen below 2 mumol/g (dry weight), the limit of detection. Growth resumed immediately upon transfer to medium containing Pi Cyclic DPG levels were also below detection in Pi-limited chemostat cultures operating at a dilution rate of 0.173 h-1 (4-h doubling time), with reservoir Pi concentrations below 200 microM. At th...

  18. Higher-order asymptotic homogenization of periodic materials with low scale separation

    NARCIS (Netherlands)

    Ameen, M.M.; Peerlings, R.H.J.; Geers, M.G.D

    2016-01-01

    In this work, we investigate the limits of classical homogenization theories pertaining to homogenization of periodic linear elastic composite materials at low scale separations and demonstrate the effectiveness of higher-order periodic homogenization in alleviating this limitation. Classical

  19. The use of light-based (optical) detection systems as adjuncts in the detection of oral cancer and oral potentially malignant disorders: a systematic review.

    Science.gov (United States)

    Rashid, A; Warnakulasuriya, S

    2015-05-01

    In recent decades, optical techniques utilising the principles of chemiluminescence and tissue autofluorescence have emerged to facilitate the early detection of any oral mucosal changes suspicious of cancer. To evaluate the effectiveness of devices that utilise the principles of chemiluminescence and tissue autofluorescence as adjuncts in the detection of oral cancer and oral potentially malignant disorders (OPMDs). A systematic review of the published literature to evaluate the effectiveness of the ViziLite(®) and ViziLite(®) Plus with toluidine blue, MicroLux™/DL and the VELscope™ as aids in the detection of oral cancer and OPMDs. Twenty-five primary studies published between 2004 and 2013 satisfied our criteria for selection - 13 utilised chemiluminescence and 12 tissue autofluorescence. Some had utilised both study methods on the same population. Chemiluminescence shows good sensitivity at detecting any OPMDs and oral cancer. However, it preferentially detects leukoplakia and may fail to spot red patches. The additive use of toluidine blue may improve specificity. Tissue autofluorescence is sensitive at detecting white, red and white and red patches, and the area of fluorescence visualisation loss (FVL) often extends beyond the clinically visible lesion. However, in addition to OPMDs, VELScope may detect erythematous lesions of benign inflammation resulting in false-positive test results. There is limited evidence for their use in primary care, and these tools are better suited to specialist clinics in which there is a higher prevalence of disease and where experienced clinicians may better discriminate between benign and malignant lesions. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Quantifying environmental limiting factors on tree cover using geospatial data.

    Science.gov (United States)

    Greenberg, Jonathan A; Santos, Maria J; Dobrowski, Solomon Z; Vanderbilt, Vern C; Ustin, Susan L

    2015-01-01

    Environmental limiting factors (ELFs) are the thresholds that determine the maximum or minimum biological response for a given suite of environmental conditions. We asked the following questions: 1) Can we detect ELFs on percent tree cover across the eastern slopes of the Lake Tahoe Basin, NV? 2) How are the ELFs distributed spatially? 3) To what extent are unmeasured environmental factors limiting tree cover? ELFs are difficult to quantify as they require significant sample sizes. We addressed this by using geospatial data over a relatively large spatial extent, where the wall-to-wall sampling ensures the inclusion of rare data points which define the minimum or maximum response to environmental factors. We tested mean temperature, minimum temperature, potential evapotranspiration (PET) and PET minus precipitation (PET-P) as potential limiting factors on percent tree cover. We found that the study area showed system-wide limitations on tree cover, and each of the factors showed evidence of being limiting on tree cover. However, only 1.2% of the total area appeared to be limited by the four (4) environmental factors, suggesting other unmeasured factors are limiting much of the tree cover in the study area. Where sites were near their theoretical maximum, non-forest sites (tree cover demand, and closed-canopy forests were not limited by any particular environmental factor. The detection of ELFs is necessary in order to fully understand the width of limitations that species experience within their geographic range.

  1. Feature-fused SSD: fast detection for small objects

    Science.gov (United States)

    Cao, Guimei; Xie, Xuemei; Yang, Wenzhe; Liao, Quan; Shi, Guangming; Wu, Jinjian

    2018-04-01

    Small objects detection is a challenging task in computer vision due to its limited resolution and information. In order to solve this problem, the majority of existing methods sacrifice speed for improvement in accuracy. In this paper, we aim to detect small objects at a fast speed, using the best object detector Single Shot Multibox Detector (SSD) with respect to accuracy-vs-speed trade-off as base architecture. We propose a multi-level feature fusion method for introducing contextual information in SSD, in order to improve the accuracy for small objects. In detailed fusion operation, we design two feature fusion modules, concatenation module and element-sum module, different in the way of adding contextual information. Experimental results show that these two fusion modules obtain higher mAP on PASCAL VOC2007 than baseline SSD by 1.6 and 1.7 points respectively, especially with 2-3 points improvement on some small objects categories. The testing speed of them is 43 and 40 FPS respectively, superior to the state of the art Deconvolutional single shot detector (DSSD) by 29.4 and 26.4 FPS.

  2. Statistical Angular Resolution Limit for Ultrawideband MIMO Noise Radar

    Directory of Open Access Journals (Sweden)

    Xiaoli Zhou

    2015-01-01

    Full Text Available The two-dimensional angular resolution limit (ARL of elevation and azimuth for MIMO radar with ultrawideband (UWB noise waveforms is investigated using statistical resolution theory. First, the signal model of monostatic UWB MIMO noise radar is established in a 3D reference frame. Then, the statistical angular resolution limits (SARLs of two closely spaced targets are derived using the detection-theoretic and estimation-theoretic approaches, respectively. The detection-theoretic approach is based on the generalized likelihood ratio test (GLRT with given probabilities of false alarm and detection, while the estimation-theoretic approach is based on Smith’s criterion which involves the Cramér-Rao lower bound (CRLB. Furthermore, the relationship between the two approaches is presented, and the factors affecting the SARL, that is, detection parameters, transmit waveforms, array geometry, signal-to-noise ratio (SNR, and parameters of target (i.e., radar cross section (RCS and direction, are analyzed. Compared with the conventional radar resolution theory defined by the ambiguity function, the SARL reflects the practical resolution ability of radar and can provide an optimization criterion for radar system design.

  3. Convolutional neural network features based change detection in satellite images

    Science.gov (United States)

    Mohammed El Amin, Arabi; Liu, Qingjie; Wang, Yunhong

    2016-07-01

    With the popular use of high resolution remote sensing (HRRS) satellite images, a huge research efforts have been placed on change detection (CD) problem. An effective feature selection method can significantly boost the final result. While hand-designed features have proven difficulties to design features that effectively capture high and mid-level representations, the recent developments in machine learning (Deep Learning) omit this problem by learning hierarchical representation in an unsupervised manner directly from data without human intervention. In this letter, we propose approaching the change detection problem from a feature learning perspective. A novel deep Convolutional Neural Networks (CNN) features based HR satellite images change detection method is proposed. The main guideline is to produce a change detection map directly from two images using a pretrained CNN. This method can omit the limited performance of hand-crafted features. Firstly, CNN features are extracted through different convolutional layers. Then, a concatenation step is evaluated after an normalization step, resulting in a unique higher dimensional feature map. Finally, a change map was computed using pixel-wise Euclidean distance. Our method has been validated on real bitemporal HRRS satellite images according to qualitative and quantitative analyses. The results obtained confirm the interest of the proposed method.

  4. Characterization of the nasal and oral microbiota of detection dogs.

    Directory of Open Access Journals (Sweden)

    Anitha Isaiah

    Full Text Available Little is known about physiological factors that affect the sense of olfaction in dogs. The objectives of this study were to describe the canine nasal and oral microbiota in detection dogs. We sought to determine the bacterial composition of the nasal and oral microbiota of a diverse population of detection canines. Nasal and oral swabs were collected from healthy dogs (n = 81 from four locations-Alabama, Georgia, California, and Texas. Nasal and oral swabs were also collected from a second cohort of detection canines belonging to three different detection job categories: explosive detection dogs (SP-E; n = 22, patrol and narcotics detection dogs (P-NDD; n = 15, and vapor wake dogs (VWD-E; n = 9. To understand if the nasal and oral microbiota of detection canines were variable, sample collection was repeated after 7 weeks in a subset of dogs. DNA was extracted from the swabs and used for 454-pyrosequencing of the16S rRNA genes. Nasal samples had a significantly lower diversity than oral samples (P<0.01. Actinobacteria and Proteobacteria were higher in nasal samples, while Bacteroidetes, Firmicutes, Fusobacteria, and Tenericutes were higher in oral samples. Bacterial diversity was not significantly different based on the detection job. No significant difference in beta diversity was observed in the nasal samples based on the detection job. In oral samples, however, ANOSIM suggested a significant difference in bacterial communities based on job category albeit with a small effect size (R = 0.1079, P = 0.02. Analysis of the composition of bacterial communities using LEfSe showed that within the nasal samples, Cardiobacterium and Riemerella were higher in VWD-E dogs, and Sphingobacterium was higher in the P-NDD group. In the oral samples Enterococcus and Capnocytophaga were higher in the P-NDD group. Gemella and Aggregatibacter were higher in S-PE, and Pigmentiphaga, Chryseobacterium, Parabacteroides amongst others were higher within the VWD-E group

  5. Characterization of the nasal and oral microbiota of detection dogs.

    Science.gov (United States)

    Isaiah, Anitha; Hoffmann, Aline Rodrigues; Kelley, Russ; Mundell, Paul; Steiner, Jörg M; Suchodolski, Jan S

    2017-01-01

    Little is known about physiological factors that affect the sense of olfaction in dogs. The objectives of this study were to describe the canine nasal and oral microbiota in detection dogs. We sought to determine the bacterial composition of the nasal and oral microbiota of a diverse population of detection canines. Nasal and oral swabs were collected from healthy dogs (n = 81) from four locations-Alabama, Georgia, California, and Texas. Nasal and oral swabs were also collected from a second cohort of detection canines belonging to three different detection job categories: explosive detection dogs (SP-E; n = 22), patrol and narcotics detection dogs (P-NDD; n = 15), and vapor wake dogs (VWD-E; n = 9). To understand if the nasal and oral microbiota of detection canines were variable, sample collection was repeated after 7 weeks in a subset of dogs. DNA was extracted from the swabs and used for 454-pyrosequencing of the16S rRNA genes. Nasal samples had a significantly lower diversity than oral samples (P<0.01). Actinobacteria and Proteobacteria were higher in nasal samples, while Bacteroidetes, Firmicutes, Fusobacteria, and Tenericutes were higher in oral samples. Bacterial diversity was not significantly different based on the detection job. No significant difference in beta diversity was observed in the nasal samples based on the detection job. In oral samples, however, ANOSIM suggested a significant difference in bacterial communities based on job category albeit with a small effect size (R = 0.1079, P = 0.02). Analysis of the composition of bacterial communities using LEfSe showed that within the nasal samples, Cardiobacterium and Riemerella were higher in VWD-E dogs, and Sphingobacterium was higher in the P-NDD group. In the oral samples Enterococcus and Capnocytophaga were higher in the P-NDD group. Gemella and Aggregatibacter were higher in S-PE, and Pigmentiphaga, Chryseobacterium, Parabacteroides amongst others were higher within the VWD-E group. Our initial

  6. Fusion of Heterogeneous Intrusion Detection Systems for Network Attack Detection

    Directory of Open Access Journals (Sweden)

    Jayakumar Kaliappan

    2015-01-01

    Full Text Available An intrusion detection system (IDS helps to identify different types of attacks in general, and the detection rate will be higher for some specific category of attacks. This paper is designed on the idea that each IDS is efficient in detecting a specific type of attack. In proposed Multiple IDS Unit (MIU, there are five IDS units, and each IDS follows a unique algorithm to detect attacks. The feature selection is done with the help of genetic algorithm. The selected features of the input traffic are passed on to the MIU for processing. The decision from each IDS is termed as local decision. The fusion unit inside the MIU processes all the local decisions with the help of majority voting rule and makes the final decision. The proposed system shows a very good improvement in detection rate and reduces the false alarm rate.

  7. Restriction Cascade Exponential Amplification (RCEA) assay with an attomolar detection limit: a novel, highly specific, isothermal alternative to qPCR.

    Science.gov (United States)

    Ghindilis, Andrey L; Smith, Maria W; Simon, Holly M; Seoudi, Ihab A; Yazvenko, Nina S; Murray, Iain A; Fu, Xiaoqing; Smith, Kenneth; Jen-Jacobson, Linda; Xu, Shuang-Yong

    2015-01-13

    An alternative to qPCR was developed for nucleic acid assays, involving signal rather than target amplification. The new technology, Restriction Cascade Exponential Amplification (RCEA), relies on specific cleavage of probe-target hybrids by restriction endonucleases (REase). Two mutant REases for amplification (Ramp), S17C BamHI and K249C EcoRI, were conjugated to oligonucleotides, and immobilized on a solid surface. The signal generation was based on: (i) hybridization of a target DNA to a Ramp-oligonucleotide probe conjugate, followed by (ii) specific cleavage of the probe-target hybrid using a non-immobilized recognition REase. The amount of Ramp released into solution upon cleavage was proportionate to the DNA target amount. Signal amplification was achieved through catalysis, by the free Ramp, of a restriction cascade containing additional oligonucleotide-conjugated Ramp and horseradish peroxidase (HRP). Colorimetric quantification of free HRP indicated that the RCEA achieved a detection limit of 10 aM (10(-17) M) target concentration, or approximately 200 molecules, comparable to the sensitivity of qPCR-based assays. The RCEA assay had high specificity, it was insensitive to non-specific binding, and detected target sequences in the presence of foreign DNA. RCEA is an inexpensive isothermal assay that allows coupling of the restriction cascade signal amplification with any DNA target of interest.

  8. Evaluation of the odd-even effect in limits of detection for electron microprobe analysis of natural minerals

    International Nuclear Information System (INIS)

    Verma, Surendra P.; Pandarinath, Kailasa; Velasco-Tapia, Fernando; Rodriguez-Rios, Rodolfo

    2009-01-01

    Limit of detection (LOD), being a fundamental quality parameter for analytical techniques, has been recently investigated and a systematic behavior has been observed for most odd-even element pairs for many techniques. However, to the best of our knowledge very few LOD data are available in published literature for electron microprobe analysis; these consist of three papers, two being on rare-earth elements and the third covering a large number of elements of atomic number between 21 and 92. These data confirm the systematic behavior of LODs for many odd-even pairs. To initiate to full this gap, we determined LODs for several major rock-forming chemical elements from Na to Fe with atomic numbers between 11 and 26, during the microprobe analysis of common minerals (olivine, plagioclase, pyroxene, amphibole, quartz, and opaques) in volcanic rocks. The odd-even effect of nuclear stability seems to be present in LOD data for most odd-even pairs investigated. Nevertheless, the experimental strategy concerning the reference materials, calibration procedure, and blank measurements, should be substantially modified to better evaluate the systematic behavior of LOD values in microprobe analysis.

  9. Evaluation of the odd-even effect in limits of detection for electron microprobe analysis of natural minerals

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Surendra P., E-mail: spv@cie.unam.mx [Departamento de Sistemas Energeticos, Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Priv. Xochicalco s/no., Col Centro, A.P. 34, Temixco, Mor. 62580 (Mexico); Pandarinath, Kailasa [Departamento de Sistemas Energeticos, Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Priv. Xochicalco s/no., Col Centro, A.P. 34, Temixco, Mor. 62580 (Mexico); Velasco-Tapia, Fernando [Facultad de Ciencias de la Tierra, Universidad Autonoma de Nuevo Leon, Carretera Linares-Cerro Prieto km. 8, Linares, N.L. 67700 (Mexico); Rodriguez-Rios, Rodolfo [Facultad de Ingenieria e Instituto de Geologia, Universidad Autonoma de San Luis Potosi, Av. Dr. Manuel Nava No. 8, Zona Universitaria, San Luis Potosi, S.L.P. 78240 (Mexico)

    2009-04-13

    Limit of detection (LOD), being a fundamental quality parameter for analytical techniques, has been recently investigated and a systematic behavior has been observed for most odd-even element pairs for many techniques. However, to the best of our knowledge very few LOD data are available in published literature for electron microprobe analysis; these consist of three papers, two being on rare-earth elements and the third covering a large number of elements of atomic number between 21 and 92. These data confirm the systematic behavior of LODs for many odd-even pairs. To initiate to full this gap, we determined LODs for several major rock-forming chemical elements from Na to Fe with atomic numbers between 11 and 26, during the microprobe analysis of common minerals (olivine, plagioclase, pyroxene, amphibole, quartz, and opaques) in volcanic rocks. The odd-even effect of nuclear stability seems to be present in LOD data for most odd-even pairs investigated. Nevertheless, the experimental strategy concerning the reference materials, calibration procedure, and blank measurements, should be substantially modified to better evaluate the systematic behavior of LOD values in microprobe analysis.

  10. Morpholinoethanesulfonic acid-based buffer system for improved detection limit and stability of the fluoride ion selective electrode

    International Nuclear Information System (INIS)

    Fouskaki, M.; Sotiropoulou, S.; Koci, M.; Chaniotakis, N.A.

    2002-01-01

    The zwitterionic morpholinoethanesulfonic acid (MES) is used as the basis for the development of a new total ionic strength adjustor buffer system for improving the analytical characteristics of fluoride sensor. Impedance analysis, atomic force microscopy (AFM) and dissolution studies of the LaF 3 crystal, together with the potential stability and sensor sensitivity over time have aided in the elucidation of the processes that take place at the surface of the LaF 3 crystal, that seem to determine the sensor behaviour. Even though AFM analysis shows that both buffers used (MES or acetate) cause a similar increase in surface roughness, the data from the other studies suggest that in the first case there is a reversible ion exchange process at the interface, while in the second case this process is irreversible, leading to fast poisoning of the crystal surface. The use of 0.5 M MES and NaCl buffer adjusted to pH 5.50 allows for the continuous operation of the sensor under flow injection analysis conditions for at least 5 days with sensitivity of 60 mV per decade [F - ], detection limit of 2.1x10 -7 M [F - ] and fast response time

  11. Asymptotic Expansions for Higher-Order Scalar Difference Equations

    Directory of Open Access Journals (Sweden)

    Ravi P. Agarwal

    2007-04-01

    Full Text Available We give an asymptotic expansion of the solutions of higher-order Poincaré difference equation in terms of the characteristic solutions of the limiting equation. As a consequence, we obtain an asymptotic description of the solutions approaching a hyperbolic equilibrium of a higher-order nonlinear difference equation with sufficiently smooth nonlinearity. The proof is based on the inversion formula for the z -transform and the residue theorem.

  12. Improved Bi film wrapped single walled carbon nanotubes for ultrasensitive electrochemical detection of trace Cr(VI)

    International Nuclear Information System (INIS)

    Ouyang, Ruizhuo; Zhang, Wangyao; Zhou, Shilin; Xue, Zi-Ling; Xu, Lina; Gu, Yingying; Miao, Yuqing

    2013-01-01

    Highlights: • Electrostatic interaction improves the quality of Bi deposition. • The designed Bi/SWNTs/GCE shows many advantages over Bi/GCE toward Cr VI detection. • The Bi/SWNTs/GCE exhibits good analyzing behavior with pretty low detection limit. • The fabricated sensor is better of reproducibility, repeatability and life time. • River samples were successfully analyzed using current sensor for Cr VI detection. -- Abstract: We report here the successful fabrication of an improved Bi film wrapped single walled carbon nanotubes modified glassy carbon electrode (Bi/SWNTs/GCE) as a highly sensitive platform for ultratrace Cr(VI) detection through catalytic adsorptive cathodic stripping voltammetry (AdCSV). The introduction of negatively charged SWNTs extraordinarily decreased the size of Bi particles to nanoscale due to electrostatic interaction which made Bi(III) cations easily attracted onto the surface of SWNTs in good order, leading to higher quality of Bi film deposition. The obtained Bi/SWNTs composite was well characterized with electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), the static water contact angle and the voltammetric measurements. The results demonstrate the improvements in the quality of Bi film deposited on the surface of SWNTs such as faster speed of electron transfer, more uniform and smoother morphology, better hydrophilicity and higher stripping signal. Using diethylene triaminepentaacetic acid (DTPA) as complexing ligand, the fabricated electrode displays a well-defined and highly sensitive peak for the reduction of Cr(III)–DTPA complex at −1.06 V (vs. Ag/AgCl) with a linear concentration range of 0–25 nM and a fairly low detection limit of 0.036 nM. No interference was found in the presence of coexisting ions, and good recoveries were achieved for the analysis of a river sample. In comparison to previous approaches using Bi film modified GCE, the newly designed electrode exhibits better

  13. Single Nanoparticle Detection Using Optical Microcavities.

    Science.gov (United States)

    Zhi, Yanyan; Yu, Xiao-Chong; Gong, Qihuang; Yang, Lan; Xiao, Yun-Feng

    2017-03-01

    Detection of nanoscale objects is highly desirable in various fields such as early-stage disease diagnosis, environmental monitoring and homeland security. Optical microcavity sensors are renowned for ultrahigh sensitivities due to strongly enhanced light-matter interaction. This review focuses on single nanoparticle detection using optical whispering gallery microcavities and photonic crystal microcavities, both of which have been developing rapidly over the past few years. The reactive and dissipative sensing methods, characterized by light-analyte interactions, are explained explicitly. The sensitivity and the detection limit are essentially determined by the cavity properties, and are limited by the various noise sources in the measurements. On the one hand, recent advances include significant sensitivity enhancement using techniques to construct novel microcavity structures with reduced mode volumes, to localize the mode field, or to introduce optical gain. On the other hand, researchers attempt to lower the detection limit by improving the spectral resolution, which can be implemented by suppressing the experimental noises. We also review the methods of achieving a better temporal resolution by employing mode locking techniques or cavity ring up spectroscopy. In conclusion, outlooks on the possible ways to implement microcavity-based sensing devices and potential applications are provided. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Computer-aided detection of pulmonary nodules: influence of nodule characteristics on detection performance

    International Nuclear Information System (INIS)

    Marten, K.; Engelke, C.; Seyfarth, T.; Grillhoesl, A.; Obenauer, S.; Rummeny, E.J.

    2005-01-01

    AIM: To evaluate prospectively the influence of pulmonary nodule characteristics on detection performances of a computer-aided diagnosis (CAD) tool and experienced chest radiologists using multislice CT (MSCT). MATERIALS AND METHODS: MSCT scans of 20 consecutive patients were evaluated by a CAD system and two independent chest radiologists for presence of pulmonary nodules. Nodule size, position, margin, matrix characteristics, vascular and pleural attachments and reader confidence were recorded and data compared with an independent standard of reference. Statistical analysis for predictors influencing nodule detection or reader performance included chi-squared, retrograde stepwise conditional logistic regression with odds ratios and nodule detection proportion estimates (DPE), and ROC analysis. RESULTS: For 135 nodules, detection rates for CAD and readers were 76.3, 52.6 and 52.6%, respectively; false-positive rates were 0.55, 0.25 and 0.15 per examination, respectively. In consensus with CAD the reader detection rate increased to 93.3%, and the false-positive rate dropped to 0.1/scan. DPEs for nodules ≤5 mm were significantly higher for ICAD than for the readers (p<0.05). Absence of vascular attachment was the only significant predictor of nodule detection by CAD (p=0.0006-0.008). There were no predictors of nodule detection for reader consensus with CAD. In contrast, vascular attachment predicted nodule detection by the readers (p=0.0001-0.003). Reader sensitivity was higher for nodules with vascular attachment than for unattached nodules (sensitivities 0.768 and 0.369; 95% confidence intervals=0.651-0.861 and 0.253-0.498, respectively). CONCLUSION: CAD increases nodule detection rates, decreases false-positive rates and compensates for deficient reader performance in detection of smallest lesions and of nodules without vascular attachment

  15. Combining satellite-based fire observations and ground-based lightning detections to identify lightning fires across the conterminous USA

    Science.gov (United States)

    Bar-Massada, A.; Hawbaker, T.J.; Stewart, S.I.; Radeloff, V.C.

    2012-01-01

    Lightning fires are a common natural disturbance in North America, and account for the largest proportion of the area burned by wildfires each year. Yet, the spatiotemporal patterns of lightning fires in the conterminous US are not well understood due to limitations of existing fire databases. Our goal here was to develop and test an algorithm that combined MODIS fire detections with lightning detections from the National Lightning Detection Network to identify lightning fires across the conterminous US from 2000 to 2008. The algorithm searches for spatiotemporal conjunctions of MODIS fire clusters and NLDN detected lightning strikes, given a spatiotemporal lag between lightning strike and fire ignition. The algorithm revealed distinctive spatial patterns of lightning fires in the conterminous US While a sensitivity analysis revealed that the algorithm is highly sensitive to the two thresholds that are used to determine conjunction, the density of fires it detected was moderately correlated with ground based fire records. When only fires larger than 0.4 km2 were considered, correlations were higher and the root-mean-square error between datasets was less than five fires per 625 km2 for the entire study period. Our algorithm is thus suitable for detecting broad scale spatial patterns of lightning fire occurrence, and especially lightning fire hotspots, but has limited detection capability of smaller fires because these cannot be consistently detected by MODIS. These results may enhance our understanding of large scale patterns of lightning fire activity, and can be used to identify the broad scale factors controlling fire occurrence.

  16. Limitations of Using IL-17A and IFN-γ-Induced Protein 10 to Detect Bovine Tuberculosis

    Science.gov (United States)

    Xin, Ting; Gao, Xintao; Yang, Hongjun; Li, Pingjun; Liang, Qianqian; Hou, Shaohua; Sui, Xiukun; Guo, Xiaoyu; Yuan, Weifeng; Zhu, Hongfei; Ding, Jiabo; Jia, Hong

    2018-01-01

    Bovine tuberculosis (bTB) is primarily caused by infection with Mycobacterium bovis, which belongs to the Mycobacterium tuberculosis complex. The airborne route is considered the most common for transmission of M. bovis, and more than 15% of cattle with bTB shed the Mycobacterium, which can be detect by nested PCR to amplify mycobacterial mpb70 from a nasal swab from a cow. To screen for cytokines fostering early and accurate detection of bTB, peripheral blood mononuclear cells were isolated from naturally M. bovis-infected, experimentally M. bovis 68002-infected, and uninfected cattle, then these cells were stimulated by PPD-B, CFP-10-ESAT-6 (CE), or phosphate-buffered saline (PBS) for 6 h. The levels of interferon gamma (IFN-γ), IFN-γ-induced protein 10 (IP-10), IL-6, IL-12, IL-17A, and tumor necrosis factor alpha mRNA were measured using real-time PCR. To explore the cytokines associated with different periods of M. bovis infection, cattle were divided into three groups: PCR-positive, PCR-negative, and uninfected using the tuberculin skin test, CFP-10/ESAT-6/TB10.4 protein cocktail-based skin test, IFN-γ release assay (IGRA), CFP-10/ESAT-6 (CE)-based IGRA, and nested PCR. The expression of IP-10, IL-17A, and IFN-γ proteins induced by PPD-B, CE, or PBS was detected by ELISA. The results showed that levels of PPD-B-stimulated IL-17A and IP-10 (mRNA and protein), and CE-induced IP-10 (mRNA and protein) were significantly higher in cattle naturally or experimentally infected with M. bovis than in those that were uninfected. The levels of PPD-B- or CE-induced IL-17A and IP-10 (protein) could be used to differentiate M. bovis-infected calves from uninfected ones for 6 to 30 weeks post-infection, whereas PPD-B- and CE-induced IP-10 and IL-17A mRNA expression could be used to differentiate M. bovis-infected calves from uninfected ones between 6 and 58 weeks post-infection. However, CE-induced IL-17A (protein) was not a reliable indicator of M. bovis infection

  17. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    International Nuclear Information System (INIS)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng

    2014-01-01

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β 2 -agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β 2 -agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β 2 -agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β 2 -agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL −1 , with the detection limits of 0.20 and 0.040 ng mL −1 (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β 2 -agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety

  18. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng, E-mail: fuzf@swu.edu.cn

    2014-08-11

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β{sub 2}-agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β{sub 2}-agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β{sub 2}-agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β{sub 2}-agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL{sup −1}, with the detection limits of 0.20 and 0.040 ng mL{sup −1} (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β{sub 2}-agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety.

  19. Clinical Application of Picodroplet Digital PCR Technology for Rapid Detection of EGFR T790M in Next-Generation Sequencing Libraries and DNA from Limited Tumor Samples.

    Science.gov (United States)

    Borsu, Laetitia; Intrieri, Julie; Thampi, Linta; Yu, Helena; Riely, Gregory; Nafa, Khedoudja; Chandramohan, Raghu; Ladanyi, Marc; Arcila, Maria E

    2016-11-01

    Although next-generation sequencing (NGS) is a robust technology for comprehensive assessment of EGFR-mutant lung adenocarcinomas with acquired resistance to tyrosine kinase inhibitors, it may not provide sufficiently rapid and sensitive detection of the EGFR T790M mutation, the most clinically relevant resistance biomarker. Here, we describe a digital PCR (dPCR) assay for rapid T790M detection on aliquots of NGS libraries prepared for comprehensive profiling, fully maximizing broad genomic analysis on limited samples. Tumor DNAs from patients with EGFR-mutant lung adenocarcinomas and acquired resistance to epidermal growth factor receptor inhibitors were prepared for Memorial Sloan-Kettering-Integrated Mutation Profiling of Actionable Cancer Targets sequencing, a hybrid capture-based assay interrogating 410 cancer-related genes. Precapture library aliquots were used for rapid EGFR T790M testing by dPCR, and results were compared with NGS and locked nucleic acid-PCR Sanger sequencing (reference high sensitivity method). Seventy resistance samples showed 99% concordance with the reference high sensitivity method in accuracy studies. Input as low as 2.5 ng provided a sensitivity of 1% and improved further with increasing DNA input. dPCR on libraries required less DNA and showed better performance than direct genomic DNA. dPCR on NGS libraries is a robust and rapid approach to EGFR T790M testing, allowing most economical utilization of limited material for comprehensive assessment. The same assay can also be performed directly on any limited DNA source and cell-free DNA. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  20. Diazonium-based impedimetric aptasensor for the rapid label-free detection of Salmonella typhimurium in food sample.

    Science.gov (United States)

    Bagheryan, Zahra; Raoof, Jahan-Bakhsh; Golabi, Mohsen; Turner, Anthony P F; Beni, Valerio

    2016-06-15

    Fast and accurate detection of microorganisms is of key importance in clinical analysis and in food and water quality monitoring. Salmonella typhimurium is responsible for about a third of all cases of foodborne diseases and consequently, its fast detection is of great importance for ensuring the safety of foodstuffs. We report the development of a label-free impedimetric aptamer-based biosensor for S. typhimurium detection. The aptamer biosensor was fabricated by grafting a diazonium-supporting layer onto screen-printed carbon electrodes (SPEs), via electrochemical or chemical approaches, followed by chemical immobilisation of aminated-aptamer. FTIR-ATR, contact angle and electrochemical measurements were used to monitor the fabrication process. Results showed that electrochemical immobilisation of the diazonium-grafting layer allowed the formation of a denser aptamer layer, which resulted in higher sensitivity. The developed aptamer-biosensor responded linearly, on a logarithm scale, over the concentration range 1 × 10(1) to 1 × 10(8)CFU mL(-1), with a limit of quantification (LOQ) of 1 × 10(1) CFU mL(-1) and a limit of detection (LOD) of 6 CFU mL(-1). Selectivity studies showed that the aptamer biosensor could discriminate S. typhimurium from 6 other model bacteria strains. Finally, recovery studies demonstrated its suitability for the detection of S. typhimurium in spiked (1 × 10(2), 1 × 10(4) and 1 × 10(6) CFU mL(-1)) apple juice samples. Copyright © 2016 Elsevier B.V. All rights reserved.