WorldWideScience

Sample records for high-voltage sf6 auto-expansion

  1. Simulation of the Process of Arc Energy-Effect in High Voltage Auto-Expansion SF6 Circuit Breaker

    International Nuclear Information System (INIS)

    Rong Mingzhe; Yang Qian; Fan Chunduo

    2005-01-01

    A new magnetic hydro-dynamics (MHD) model of arc in H.V. auto-expansion SF 6 circuit breaker that takes into consideration nozzle ablation due to both radiation and thermal conduction is presented in this paper. The effect of PTFE (polytetrafluorethylene) vapor is considered in the mass, momentum and energy conservation equations of the constructed model. Then, the gas flow fields with and without conduction considered are simulated. By comparing the aforementioned two results, it is indicated that the arc's maximal temperature with conduction considered is 90 percent of that without considering conduction

  2. Advances in high voltage insulation and arc interruption in SF6 and vacuum

    CERN Document Server

    Maller, V N

    1982-01-01

    Advances in High Voltage Insulation and Arc Interruption in SF6 and Vacuum deals with high voltage breakdown and arc extinction in sulfur hexafluoride (SF6) and high vacuum, with special emphasis on the application of these insulating media in high voltage power apparatus and devices. The design and developmental aspects of various high voltage power apparatus using SF6 and high vacuum are highlighted. This book is comprised of eight chapters and opens with a discussion on electrical discharges in SF6 and high vacuum, along with the properties and handling of SF6 gas. The following chapters fo

  3. Breakdown Voltage of CF3CHCl2 gas an Alternative to SF6 Gas using HV Test and Bonding Energy Methods

    Science.gov (United States)

    Juliandhy, Tedy; Haryono, T.; Suharyanto; Perdana, Indra

    2018-04-01

    For more than two decades of Sulphur Hexafluoride (SF6) gases is used as a gas insulation in high voltage equipment especially in substations. In addition to getting an advantage as an insulating gas. SF6 gas is recognized as one of the greenhouse effect gases that cause global warming. Under the Kyoto Protocol, SF6 gas is one of those gases whose use is restricted and gradually reduced to the presence of a replacement gas for SF6 gas. One of the alternative gas alternatives which have the potential of replacing SF6 gas as an insulating gas in Gas Insulated Switchgear (GIS) equipment in the substation is Dichlorotrifluoroethane (CF3CHCl2) gas. The purpose of this paper is to enable a comparison of breakdown voltage with high voltage test and method of calculating Bonding energy to Dichlorotrifluoroethane gas as substitute gas for SF6 gas. At 0.1 bar gas pressure obtained an average breakdown voltage of 18.68 kV / mm at 25oC chamber temperature and has the highest breakdown voltage at 50oC with a breakdown voltage of 19.56 kV / mm. The CF3CHCl2 gas has great potential as an insulating gas because it has more insulation ability high of SF6 gas, and is part of the gas recommended under the Kyoto Protocol. Gas CF3CHCl2 has the capacity to double the value of electronegativity greater than SF6 gas as a major requirement of gas isolation and has a value of Global Warming Potential (GWP) and Ozone Depleting lower than from SF6 gas.

  4. Interaction of intense electromagnetic fields with SF6 molecules and clusters in supersonic expansion

    International Nuclear Information System (INIS)

    Airoldi, V.J.T.

    1987-01-01

    A method of measuring SF 6 cluster formation and inhibition in pulsed supersonic expansion in the presence of intense electromagnetic radiation is presented. The characterization of the expansion of SF 6 molecules was done and, the extension of the collision region was determined. An improved unidimensional theory of supersonic expansion showed good agreement with the experimental results. The spectra of multiphoton absorption of SF 6 molecules in supersonic jet and the average energy absorved by each molecule were determined. The absorption spectra of molecule in the collision region present absorption maxima different from those obtained in the collisionless region. The results, if compared with the literature data, show good agreement, with a small difference in the spetra corresponding to the collisionless region. This difference was observed, for the first time in the multiphoton absorption and is attribuited to cluster formation in the jet. A new technique for measuring cluster formation in the supersonic jet, based on determination of the spatial distribution of the energy of molecules in the jet after passing through a skimmer located in the collision region is shown. The inhibition of cluster formation, due to the incidence of intense electromagnetic radiation from a CO 2 -TEA pulsed laser in the initial collision region of the jet, causes a second expansion in the skimmer. The results obtained show that this method can lead to a new isotope separation process. All the parts of the experimental set up, for example, high vacuum system, pulsed valve and pyroelectric detector, were developed and constructed specially for the experiment. (Author) [pt

  5. Abatement cost of SF6 emissions from medium voltage switchgear. Validation of recent studies for the European Commission

    Energy Technology Data Exchange (ETDEWEB)

    Benner, J.; Van Lieshout, M.; Croezen, H.

    2012-05-15

    Sulphur hexafluoride (SF6) is a gas with applications including use as an insulator and switching medium in medium voltage (MV) switchgear. While having certain unique properties, it is also a greenhouse gas, with a 22,800 times greater impact than CO2 and an atmospheric lifetime of over 3,000 years. Although the use of SF6 in MV switchgear can be avoided, according to recent studies for the European Commission, the abatement costs are high. This study validates the calculated cost levels as well as the general feasibility of determining a fixed cost figure for this purpose. This analysis yields a result which differs from the earlier studies, particularly with respect to the cost aspect, but also in other areas. CE Delft concludes that for the majority of applications cost-effective SF6-free options are available, leading to abatement costs for the use of SF6 in MV switchgear that range from - 40 to 0 euro/tCO2 eq., for all types of switchgear, with voltage levels below 25 kV and situated on relatively dry locations.

  6. Electrochemical and Infrared Absorption Spectroscopy Detection of SF6 Decomposition Products

    OpenAIRE

    Dong, Ming; Zhang, Chongxing; Ren, Ming; Albarracín, Ricardo; Ye, Rixin

    2017-01-01

    Sulfur hexafluoride (SF6) gas-insulated electrical equipment is widely used in high-voltage (HV) and extra-high-voltage (EHV) power systems. Partial discharge (PD) and local heating can occur in the electrical equipment because of insulation faults, which results in SF6 decomposition and ultimately generates several types of decomposition products. These SF6 decomposition products can be qualitatively and quantitatively detected with relevant detection methods, and such detection contributes ...

  7. Design of auto-control high-voltage control system of pulsed neutron generator

    International Nuclear Information System (INIS)

    Lv Juntao

    2008-01-01

    It is difficult to produce multiple anode controlling time sequences under different logging mode for the high-voltage control system of the conventional pulsed neutron generator. It is also difficult realize sequential control among anode high-voltage, filament power supply and target voltage to make neutron yield stable. To these problems, an auto-control high-voltage system of neutron pulsed generator was designed. It not only can achieve anode high-voltage double blast time sequences, which can measure multiple neutron blast time sequences such as Σ, activated spectrum, etc. under inelastic scattering mode, but also can realize neutron generator real-time measurement of multi-state parameters and auto-control such as target voltage pulse width modulation (PWM), filament current, anode current, etc., there by it can produce stable neutron yield and realize stable and accurate measurement of the pulsed neutron full spectral loging tool. (authors)

  8. Prediction of breakdown voltages in novel gases for high voltage insulation

    International Nuclear Information System (INIS)

    Koch, M.

    2015-01-01

    This thesis submitted to the Swiss Federal Institute of Technology ETH in Zurich examines the use of sulphur hexafluoride (SF_6) and similar gases as important insulation media for high voltage equipment. Due to its superior insulation properties, SF_6 is widely used in gas-insulated switchgear. However, the gas also has a very high global warming potential and the content of SF_6 in the atmosphere is constantly increasing. The search for new insulation gases using classical breakdown experiments is discussed. A model for SF_6 based on the stepped leader model is described. This calculates the breakdown voltages in arbitrary electrode configurations and under standard voltage waveforms. Thus, the thesis provides a method for the prediction of breakdown voltages of arbitrary field configurations under standard voltage waveforms for gases with electron-attaching properties. With this, further gases can be characterized for usage as high voltage insulation media

  9. Prediction of breakdown voltages in novel gases for high voltage insulation

    Energy Technology Data Exchange (ETDEWEB)

    Koch, M.

    2015-07-01

    This thesis submitted to the Swiss Federal Institute of Technology ETH in Zurich examines the use of sulphur hexafluoride (SF{sub 6}) and similar gases as important insulation media for high voltage equipment. Due to its superior insulation properties, SF{sub 6} is widely used in gas-insulated switchgear. However, the gas also has a very high global warming potential and the content of SF{sub 6} in the atmosphere is constantly increasing. The search for new insulation gases using classical breakdown experiments is discussed. A model for SF{sub 6} based on the stepped leader model is described. This calculates the breakdown voltages in arbitrary electrode configurations and under standard voltage waveforms. Thus, the thesis provides a method for the prediction of breakdown voltages of arbitrary field configurations under standard voltage waveforms for gases with electron-attaching properties. With this, further gases can be characterized for usage as high voltage insulation media.

  10. Preliminary comparison of MP sparking characteristics for SF6 insulating gas mixtures and pure SF6

    International Nuclear Information System (INIS)

    Lindgren, R.; Wegner, H.E.

    1978-01-01

    Operation of the Brookhaven MP-7 tandem Van de Graaff accelerator with pure SF 6 insulating gas is described. Sparking and terminal voltage were monitored and are compared for operation with a mixture of SF 6 , N 2 , CO 2 and O 2 . The accelerator was found to be more difficult to operate with pure SF 6

  11. Thermophysical and radiation properties of high-temperature C4F8-CO2 mixtures to replace SF6 in high-voltage circuit breakers

    Science.gov (United States)

    Zhong, Linlin; Cressault, Yann; Teulet, Philippe

    2018-03-01

    C4F8-CO2 mixtures are one of the potential substitutes to SF6 in high-voltage circuit breakers. However, the arc quenching ability of C4F8-CO2 mixtures is still unknown. In order to provide the necessary basic data for the further investigation of arc quenching performance, the compositions, thermodynamic properties, transport coefficients, and net emission coefficients (NEC) of various C4F8-CO2 mixtures are calculated at temperatures of 300-30 000 K in this work. The thermodynamic properties are presented as the product of mass density and specific heat, i.e., ρCp. The transport coefficients include electrical conductivity, viscosity, and thermal conductivity. The atomic and molecular radiation are both taken into account in the calculation of NEC. The comparison of the properties between SF6 and C4F8-CO2 mixtures is also discussed to find their differences. The results of compositions show that C4F8-CO2 mixtures have a distinctive advantage over other alternative gases e.g., CF3I and C3F8, because the dissociative product (i.e., C4F6) of C4F8 at low temperatures has a very high dielectric strength. This is good for an arc quenching medium to endure the arc recovery phase. Compared with SF6, C4F8-CO2 mixtures present lower ρCp at temperatures below 2800 K and larger thermal conductivity above 2800 K. Based on the position of peaks in thermal conductivity, we predict that the cooling of C4F8-CO2 arc will be slowed down at higher temperatures than that of SF6 arc. It is also found that the mixing of CO2 shows slight effects on the electrical conductivity and NEC of C4F8-CO2 mixtures.

  12. An optical sensors for monitoring SF6 dissociation in a corona discharge

    International Nuclear Information System (INIS)

    Irawan, R.; Scelsi, G.B.; Woolsey, G.A.

    1999-01-01

    Sulphur hexafluoride (SF 6 ) is a chemically inert gas (Schumb, 1947) and has high dielectric strength, 3 times greater than air (Morrison and Robins, 1994). In high voltage systems, it is used both as a dielectric and an arc-quenching medium. An electrical breakdown event such as a partial discharge (corona) or arc will dissociate SF 6 into sulphur fluorides, sulphur and fluorine. In a contaminant-free environment, the dissociation products recombine back to SF 6 after extinction of the electrical discharge. Otherwise, some of the products will react with contaminants such as water vapour and oxygen, and with the metal surfaces and electrodes of the discharge chamber, to produce by-products including gaseous sulphur oxyfluorides and solid by-products (Van Brunt, 1985; Griffin et al, 1990 and Vukovic, 1997). As a consequence, a reduction in SF 6 concentration takes place, and the insulating efficiency of the system is degraded. If the SF 6 is not renewed, failure of the high voltage system is likely to eventually occur. One method of monitoring a system is to look for the presence of partial discharges, using techniques such as ultrasonic wave detection (Auckland et al, 1996) or fluorescent plastic fibre (Kurosawa et al., 1997). More directly, the integrity of the SF 6 may be examined using techniques such as mass spectrometry, gas chromatography-mass spectrometry and Fourier Transform Infra-Red Spectroscopy. Such techniques, however, are bulky and require gas samples to be extracted, and so they are unsuited to field use. Since SF 6 insulating systems involve high voltages and a high level of electromagnetic interference, direct in-situ optical monitoring appears to provide the best approach. This paper describes the development of such an optical sensing technique, specifically for continuous monitoring of SF 6 degradation in partial or corona discharges

  13. Electrochemical and Infrared Absorption Spectroscopy Detection of SF6 Decomposition Products

    Directory of Open Access Journals (Sweden)

    Ming Dong

    2017-11-01

    Full Text Available Sulfur hexafluoride (SF6 gas-insulated electrical equipment is widely used in high-voltage (HV and extra-high-voltage (EHV power systems. Partial discharge (PD and local heating can occur in the electrical equipment because of insulation faults, which results in SF6 decomposition and ultimately generates several types of decomposition products. These SF6 decomposition products can be qualitatively and quantitatively detected with relevant detection methods, and such detection contributes to diagnosing the internal faults and evaluating the security risks of the equipment. At present, multiple detection methods exist for analyzing the SF6 decomposition products, and electrochemical sensing (ES and infrared (IR spectroscopy are well suited for application in online detection. In this study, the combination of ES with IR spectroscopy is used to detect SF6 gas decomposition. First, the characteristics of these two detection methods are studied, and the data analysis matrix is established. Then, a qualitative and quantitative analysis ES-IR model is established by adopting a two-step approach. A SF6 decomposition detector is designed and manufactured by combining an electrochemical sensor and IR spectroscopy technology. The detector is used to detect SF6 gas decomposition and is verified to reliably and accurately detect the gas components and concentrations.

  14. Electrochemical and Infrared Absorption Spectroscopy Detection of SF6 Decomposition Products

    Science.gov (United States)

    Dong, Ming; Ren, Ming; Ye, Rixin

    2017-01-01

    Sulfur hexafluoride (SF6) gas-insulated electrical equipment is widely used in high-voltage (HV) and extra-high-voltage (EHV) power systems. Partial discharge (PD) and local heating can occur in the electrical equipment because of insulation faults, which results in SF6 decomposition and ultimately generates several types of decomposition products. These SF6 decomposition products can be qualitatively and quantitatively detected with relevant detection methods, and such detection contributes to diagnosing the internal faults and evaluating the security risks of the equipment. At present, multiple detection methods exist for analyzing the SF6 decomposition products, and electrochemical sensing (ES) and infrared (IR) spectroscopy are well suited for application in online detection. In this study, the combination of ES with IR spectroscopy is used to detect SF6 gas decomposition. First, the characteristics of these two detection methods are studied, and the data analysis matrix is established. Then, a qualitative and quantitative analysis ES-IR model is established by adopting a two-step approach. A SF6 decomposition detector is designed and manufactured by combining an electrochemical sensor and IR spectroscopy technology. The detector is used to detect SF6 gas decomposition and is verified to reliably and accurately detect the gas components and concentrations. PMID:29140268

  15. Electron Transport Coefficients and Effective Ionization Coefficients in SF6-O2 and SF6-Air Mixtures Using Boltzmann Analysis

    Science.gov (United States)

    Wei, Linsheng; Xu, Min; Yuan, Dingkun; Zhang, Yafang; Hu, Zhaoji; Tan, Zhihong

    2014-10-01

    The electron drift velocity, electron energy distribution function (EEDF), density-normalized effective ionization coefficient and density-normalized longitudinal diffusion velocity are calculated in SF6-O2 and SF6-Air mixtures. The experimental results from a pulsed Townsend discharge are plotted for comparison with the numerical results. The reduced field strength varies from 40 Td to 500 Td (1 Townsend=10-17 V·cm2) and the SF6 concentration ranges from 10% to 100%. A Boltzmann equation associated with the two-term spherical harmonic expansion approximation is utilized to gain the swarm parameters in steady-state Townsend. Results show that the accuracy of the Boltzmann solution with a two-term expansion in calculating the electron drift velocity, electron energy distribution function, and density-normalized effective ionization coefficient is acceptable. The effective ionization coefficient presents a distinct relationship with the SF6 content in the mixtures. Moreover, the E/Ncr values in SF6-Air mixtures are higher than those in SF6-O2 mixtures and the calculated value E/Ncr in SF6-O2 and SF6-Air mixtures is lower than the measured value in SF6-N2. Parametric studies conducted on these parameters using the Boltzmann analysis offer substantial insight into the plasma physics, as well as a basis to explore the ozone generation process.

  16. Supershort avalanche electron beam in SF6 and krypton

    Science.gov (United States)

    Zhang, Cheng; Tarasenko, Victor F.; Gu, Jianwei; Baksht, Evgeni Kh.; Beloplotov, Dmitry V.; Burachenko, Alexander G.; Yan, Ping; Lomaev, Mikhail I.; Shao, Tao

    2016-03-01

    Runaway electrons play an important role in the avalanche formation in nanosecond- and subnanosecond- pulse discharges. In this paper, characteristics of a supershort avalanche electron beam (SAEB) generated at the subnanosecond and nanosecond breakdown in sulfur hexafluoride (SF6 ) in an inhomogeneous electric field were studied. One pulser operated at negative polarity with voltage pulse amplitude of ˜130 kV and rise time of 0.3 ns. The other pulser operated at negative polarity with voltage pulse amplitude of 70 kV and rise time of ˜1.6 ns . SAEB parameters in SF6 are compared with those obtained in krypton (Kr), nitrogen (N2 ), air, and mixtures of SF6 with krypton or nitrogen. Experimental results showed that SAEB currents appeared during the rise-time of the voltage pulse for both pulsers. Moreover, amplitudes of the SAEB current in SF6 and Kr approximately ranged from several to tens of milliamps at atmospheric pressure, which were smaller than those in N2 and air (ranging from hundreds of milliamps to several amperes). Furthermore, the concentration of SF6 additive could significantly reduce the SAEB current in N2-SF6 mixture, but it slightly affected the SAEB current in Kr -SF6 mixture because of the atomic/molecular ionization cross section of the gas had a much greater impact on the SAEB current rather than the electronegativity.

  17. Supershort avalanche electron beam in SF_{6} and krypton

    Directory of Open Access Journals (Sweden)

    Cheng Zhang (章程

    2016-03-01

    Full Text Available Runaway electrons play an important role in the avalanche formation in nanosecond- and subnanosecond- pulse discharges. In this paper, characteristics of a supershort avalanche electron beam (SAEB generated at the subnanosecond and nanosecond breakdown in sulfur hexafluoride (SF_{6} in an inhomogeneous electric field were studied. One pulser operated at negative polarity with voltage pulse amplitude of ∼130  kV and rise time of 0.3 ns. The other pulser operated at negative polarity with voltage pulse amplitude of 70 kV and rise time of ∼1.6  ns. SAEB parameters in SF_{6} are compared with those obtained in krypton (Kr, nitrogen (N_{2}, air, and mixtures of SF_{6} with krypton or nitrogen. Experimental results showed that SAEB currents appeared during the rise-time of the voltage pulse for both pulsers. Moreover, amplitudes of the SAEB current in SF_{6} and Kr approximately ranged from several to tens of milliamps at atmospheric pressure, which were smaller than those in N_{2} and air (ranging from hundreds of milliamps to several amperes. Furthermore, the concentration of SF_{6} additive could significantly reduce the SAEB current in N_{2}-SF_{6} mixture, but it slightly affected the SAEB current in Kr-SF_{6} mixture because of the atomic/molecular ionization cross section of the gas had a much greater impact on the SAEB current rather than the electronegativity.

  18. A comparison between spectra of runaway electron beams in SF6 and air

    International Nuclear Information System (INIS)

    Zhang, Cheng; Wang, Ruexue; Yan, Ping; Shao, Tao; Tarasenko, Victor; Gu, Jianwei; Baksht, Evgenii

    2015-01-01

    Runaway electron (RAE) with extremely high-energy plays important role on the avalanche propagation, streamer formation, and ionization waves in nanosecond-pulse discharges. In this paper, the generation of a supershort avalanche electron beam (SAEB) in SF 6 and air in an inhomogeneous electric field is investigated. A VPG-30-200 generator with a pulse rise time of ∼1.6 ns and a full width at half maximum of 3–5 ns is used to produce RAE beams. The SAEBs in SF 6 and air are measured by using aluminum foils with different thicknesses. Furthermore, the SAEB spectra in SF 6 and air at pressures of 7.5 Torr, 75 Torr, and 750 Torr are compared. The results showed that amplitude of RAE beam current generated at the breakdown in SF 6 was approximately an order of magnitude less than that in air. The energy of SAEB in air was not smaller than that in SF 6 in nanosecond-pulse discharges under otherwise equal conditions. Moreover, the difference between the maximum energy of the electron distributions in air and SF 6 decreased when the rise time of the voltage pulse increased. It was because the difference between the breakdown voltages in air and SF 6 decreased when the rise time of the voltage pulse increased

  19. A comparison between spectra of runaway electron beams in SF6 and air

    Science.gov (United States)

    Zhang, Cheng; Tarasenko, Victor; Gu, Jianwei; Baksht, Evgenii; Wang, Ruexue; Yan, Ping; Shao, Tao

    2015-12-01

    Runaway electron (RAE) with extremely high-energy plays important role on the avalanche propagation, streamer formation, and ionization waves in nanosecond-pulse discharges. In this paper, the generation of a supershort avalanche electron beam (SAEB) in SF6 and air in an inhomogeneous electric field is investigated. A VPG-30-200 generator with a pulse rise time of ˜1.6 ns and a full width at half maximum of 3-5 ns is used to produce RAE beams. The SAEBs in SF6 and air are measured by using aluminum foils with different thicknesses. Furthermore, the SAEB spectra in SF6 and air at pressures of 7.5 Torr, 75 Torr, and 750 Torr are compared. The results showed that amplitude of RAE beam current generated at the breakdown in SF6 was approximately an order of magnitude less than that in air. The energy of SAEB in air was not smaller than that in SF6 in nanosecond-pulse discharges under otherwise equal conditions. Moreover, the difference between the maximum energy of the electron distributions in air and SF6 decreased when the rise time of the voltage pulse increased. It was because the difference between the breakdown voltages in air and SF6 decreased when the rise time of the voltage pulse increased.

  20. A comparison between spectra of runaway electron beams in SF{sub 6} and air

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Cheng; Wang, Ruexue; Yan, Ping; Shao, Tao, E-mail: st@mail.iee.ac.cn [Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100190 (China); Key Laboratory of Power Electronics and Electric Drive, Chinese Academy of Sciences, Beijing 100190 (China); Tarasenko, Victor [Institute of High Current Electronics, 2/3 Akademichesky Ave., Tomsk 634055 (Russian Federation); National Research Tomsk State University, 36 Lenin Ave., Tomsk 634050 (Russian Federation); Gu, Jianwei [Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100190 (China); Baksht, Evgenii [Institute of High Current Electronics, 2/3 Akademichesky Ave., Tomsk 634055 (Russian Federation)

    2015-12-15

    Runaway electron (RAE) with extremely high-energy plays important role on the avalanche propagation, streamer formation, and ionization waves in nanosecond-pulse discharges. In this paper, the generation of a supershort avalanche electron beam (SAEB) in SF{sub 6} and air in an inhomogeneous electric field is investigated. A VPG-30-200 generator with a pulse rise time of ∼1.6 ns and a full width at half maximum of 3–5 ns is used to produce RAE beams. The SAEBs in SF{sub 6} and air are measured by using aluminum foils with different thicknesses. Furthermore, the SAEB spectra in SF{sub 6} and air at pressures of 7.5 Torr, 75 Torr, and 750 Torr are compared. The results showed that amplitude of RAE beam current generated at the breakdown in SF{sub 6} was approximately an order of magnitude less than that in air. The energy of SAEB in air was not smaller than that in SF{sub 6} in nanosecond-pulse discharges under otherwise equal conditions. Moreover, the difference between the maximum energy of the electron distributions in air and SF{sub 6} decreased when the rise time of the voltage pulse increased. It was because the difference between the breakdown voltages in air and SF{sub 6} decreased when the rise time of the voltage pulse increased.

  1. Abnormal polarity effect in nanosecond-pulse breakdown of SF6 and nitrogen

    International Nuclear Information System (INIS)

    Shao, Tao; Tarasenko, Victor F.; Zhang, Cheng; Beloplotov, Dmitry S.; Yang, Wenjin; Lomaev, Mikhail I.; Zhou, Zhongsheng; Sorokin, Dmitry A.; Yan, Ping

    2014-01-01

    The breakdown of gas gaps in an inhomogeneous electric field at subnanosecond and nanosecond voltage pulse rise times are studied, and the famous polarity effect in point-to-plane gaps is investigated. It is shown that at a voltage pulse rise time of ∼0.5 ns, the inversion of polarity effect takes place not only in electronegative gases such as SF 6 , but also occurs in electropositive nitrogen. The inversion of polarity effect is related to a delay of electron emission from the plane cathode on arrival of the ionization wave front anode to the cathode. It is found that with a voltage pulse rise time of ∼0.5 ns, the inversion of polarity effect occurs at SF 6 and SF 6 –N 2 pressures of 0.25 MPa and lower, and with a voltage pulse rise time of 15 ns, at a SF 6 pressure lower than 0.12 MPa.

  2. AUTO-EXPANSIVE FLOW

    Science.gov (United States)

    Physics suggests that the interplay of momentum, continuity, and geometry in outward radial flow must produce density and concomitant pressure reductions. In other words, this flow is intrinsically auto-expansive. It has been proposed that this process is the key to understanding...

  3. Two-temperature transport coefficients of SF6–N2 plasma

    International Nuclear Information System (INIS)

    Yang, Fei; Chen, Zhexin; Wu, Yi; Rong, Mingzhe; Wang, Chunlin; Guo, Anxiang; Liu, Zirui

    2015-01-01

    Sulfur hexafluoride (SF 6 ) is widely adopted in electric power industry, especially in high-voltage circuit breakers and gas-insulated switchgear. However, the use of SF 6 is limited by its high liquidation temperature and high global warming potential. Recently, research shows SF 6 –N 2 mixture, which shows environmental friendliness and good electrical properties, may be a feasible substitute for pure SF 6 . This paper is devoted to the calculation of and transport coefficients of SF 6 –N 2 mixture under both LTE (local thermodynamic equilibrium) and non-LTE condition. The two–temperature mass action law was used to determine the composition. The transport coefficients were calculated by classical Chapman–Enskog method simplified by Devoto. The thermophysical properties are presented for electron temperatures of 300–40 000 K, ratios of electron to heavy species temperature of 1–10 and N 2 mole fraction of 0%–100% at atmospheric pressure. The ionization processes under both LTE and non-LTE have been discussed. The results show that deviations from local thermodynamic equilibrium significantly affect the properties of SF 6 –N 2 plasma, especially before the plasma is fully ionized. The different influence of N 2 on properties for SF 6 –N 2 plasma in and out of LTE has been found. The results will serve as reliable reference data for computational simulation of the behavior of SF 6 –N 2 plasmas

  4. SF6-alternative gases for application in gas-insulated switchgear

    Science.gov (United States)

    Li, Xingwen; Zhao, Hu; Murphy, Anthony B.

    2018-04-01

    The environmental problems caused by greenhouse gases have received unprecedented attention. Sulfur hexafluoride (SF6), which is the preferred gas for use in gas-insulated switchgear (circuit breakers, disconnect switches, etc. for high-voltage electrical circuits), has a very high global warming potential, and there is a large international effort to find alternative gases. Recently, this effort has made important progress, with promising alternative gases being identified and tested. An overview, in particular the current state of the art, of the study of SF6-alternative gases is presented in the paper. The review focuses on the application of the SF6-alternative gases in gas-insulated switchgear, with detailed analysis of calculations and measurements of their basic physical properties, dielectric strengths, and arc-quenching capabilities. Finally, a discussion of and perspectives on current research and future research directions are presented.

  5. Present and future environmental ''problems'' with SF6 and other fluorinated gases

    International Nuclear Information System (INIS)

    Brunt, R.J. Van

    1996-01-01

    Sulfur hexafluoride (SF 6 ) is widely used as an insulating and arc interrupting gas in high-voltage systems and has found application in plasma processing of materials. However, SF 6 is known to decompose in electrical discharges to form toxic and corrosive gaseous compounds such as SOF 4 , SOF 2 , SO 2 F 2 , and HF. Of particular concern are the species S 2 F 10 and S 2 O 2 F 10 that are known to be highly toxic and to be formed in corona, spark, and arc discharges in high-pressure SF 6 . The conditions under which these byproducts are formed, the methods for removal, and the possible hazards that they present are reviewed. Sulfur hexafluoride is also an efficient absorber of infrared radiation and is estimated to have a global warning potential that is 2.5 x 10 4 times greater than that of CO 2 . Methods that have been proposed to control the use of SF 6 and reduce the rate of its release into the atmosphere will be examined. The advantages, disadvantages, and likely problems with finding technically feasible and environmentally acceptable replacements for SF 6 will be discussed

  6. Two-temperature transport coefficients of SF{sub 6}–N{sub 2} plasma

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Fei; Chen, Zhexin; Wu, Yi, E-mail: wuyic51@mail.xjtu.edu.cn; Rong, Mingzhe; Wang, Chunlin [State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi' an Jiaotong University, Xi' an 710049 (China); Guo, Anxiang; Liu, Zirui [Electric Power Research Institute of State Grid Shaanxi Electric Power Company, Xian (China)

    2015-10-15

    Sulfur hexafluoride (SF{sub 6}) is widely adopted in electric power industry, especially in high-voltage circuit breakers and gas-insulated switchgear. However, the use of SF{sub 6} is limited by its high liquidation temperature and high global warming potential. Recently, research shows SF{sub 6}–N{sub 2} mixture, which shows environmental friendliness and good electrical properties, may be a feasible substitute for pure SF{sub 6}. This paper is devoted to the calculation of and transport coefficients of SF{sub 6}–N{sub 2} mixture under both LTE (local thermodynamic equilibrium) and non-LTE condition. The two–temperature mass action law was used to determine the composition. The transport coefficients were calculated by classical Chapman–Enskog method simplified by Devoto. The thermophysical properties are presented for electron temperatures of 300–40 000 K, ratios of electron to heavy species temperature of 1–10 and N{sub 2} mole fraction of 0%–100% at atmospheric pressure. The ionization processes under both LTE and non-LTE have been discussed. The results show that deviations from local thermodynamic equilibrium significantly affect the properties of SF{sub 6}–N{sub 2} plasma, especially before the plasma is fully ionized. The different influence of N{sub 2} on properties for SF{sub 6}–N{sub 2} plasma in and out of LTE has been found. The results will serve as reliable reference data for computational simulation of the behavior of SF{sub 6}–N{sub 2} plasmas.

  7. Screening test of relays used under pressurized sulfur hexafluoride (SF6)

    International Nuclear Information System (INIS)

    Kutsukake, Kenichi; Matsuda, Makoto; Hanashima, Susumu; Obara, Kenjiro

    2008-01-01

    Many measurement and control devices inside of a high voltage terminal of the JAEA-Tokai tandem accelerator are operated under pressurized sulfur hexafluoride gas (SF 6 ) of 0.5 MPa. This screening test has been carried out to select a relay, which is usable under the pressurized SF 6 for turn on and off a large current of the devices, from commercial relays used in the atmospheric condition. Four kinds of relays were tested: electromechanical relay (EMR), magnet contactor (MAG), solid-state relay (SSR) and hybrid relay (HYB). Temperature and appearance changes of the relay were collected as measurement items. In addition, a reason of contact trouble of the relays was considered from the results of qualitative elementary analysis and observation of the contact surface using the EDS (energy-dispersive X-ray spectroscopy) and the SEM (scanning electron microscope). As a result, the EMR and the MAG showed irregular contact in spite of input voltage and electric current had fed to an operational coil of the relay normally. It is caused by the sulfide or fluoride compounds, which were formed by chemical reaction between metals and sulfur or hydrogen fluoride due to dissociation of SF 6 in electric arcs. On the other hand, the performance of the SSR and the HYB is better than the EMR and the MAG, and it was found that these relays are available in the pressurized SF 6 of 0.5MPa in spite of the standard specification. (author)

  8. Dielectric properties for SF6 and SF6 mixtures predicted from basic data

    International Nuclear Information System (INIS)

    Kline, L.E.; Davies, D.K.; Chen, C.L.; Chantry, P.J.

    1979-01-01

    We have calculated α and eta, the ionization and attachment coefficients, and (E/N) *, the limiting breakdown electric-field--to--gas-density ratio, in SF 6 and SF 6 mixtures by numerically solving the Boltzmann equation for the electron energy distribution. The calculations require a knowledge of several electron collision cross sections. Published momentum transfer and ionization cross sections for SF 6 were used. We measured various attachment cross sections for SF 6 using electron-beam techniques with mass spectrometric ion detection. We determined a total cross section for electronic excitation of SF 6 by comparing the predicted values of α, eta, and (E/N) * with our measured values obtained from spatial current growth experiments in SF 6 in uniform fields over an extended range of E/N. With this self-consistent set of SF 6 cross sections, together with published He and N 2 cross sections, it was then possible to predict the dielectric properties of SF 6 -He and SF 6 -N 2 mixtures. Published experimental values of α for the SF 6 -He mixtures lie between the values of α calculated with and without ionization of SF 6 by excited He atoms. Published experimental values of (E/N) * agree with our calculations to within 5% in both the SF 6 -He and the SF 6 -N 2 mixtures

  9. Electron-transport, ionization, attachment, and dissociation coefficients in SF6 and its mixtures

    International Nuclear Information System (INIS)

    Phelps, A.V.; Van Brunt, R.J.

    1988-01-01

    An improved set of electron-collision cross sections is derived for SF 6 and used to calculate transport, ionization, attachment, and dissociation coefficients for pure SF 6 and mixtures of SF 6 with N 2 , O 2 , and Ne. The SF 6 cross sections differ from previously published sets primarily at very low and high electron energies. At energies below 0.03 eV the attachment cross section is adjusted to fit recent electron swarm experiments, while the elastic momentum transfer cross section is increased to the theoretical limit. At high energies an allowance is made for the excitation of highly excited levels as observed in electron beam experiments. The cross-section sets used for the admixed gases have previously been published. Electron kinetic energy distributions computed from numerical solutions of the electron-transport (Boltzmann) equation using the two-term, spherical harmonic expansion approximation were used to obtain electron-transport and reaction coefficients as functions of E/N and the fractional concentration of SF 6 . Here E is the electric field strength and N is the gas number density. Attachment rate data for low concentrations of SF 6 in N 2 are used to test the attachment cross sections. Particular attention is given to the calculation of transport and reaction coefficients at the critical E/N = (E/N)/sub c/ at which the ionization and attachment rates are equal

  10. Conceptual design of pulsed high voltage and high precision power supply for a cyclotron auto-resonance maser (CARM) for plasma heating

    International Nuclear Information System (INIS)

    Zito, Pietro; Maffia, Giuseppe; Lampasi, Alessandro

    2015-01-01

    Highlights: • ENEA started a project to develop a cyclotron auto-resonance maser (CARM). • This facility requires an advanced pulsed high voltage power supply (HVPS). • The conceptual design answers to the performances requested for CARM HVPS. • The pulse transformer parameters were estimated according to IEEE standards. • PWM PID-based controller has been optimized to follow very fast rectangular pulses. - Abstract: Due to the high electron temperature during the plasma burning, both a higher power (>1 MW) and a higher frequency (up to 300 GHz) are required for plasma heating in future fusion experiments like DEMO. For this task, ENEA started a project to develop a cyclotron auto-resonance maser (CARM) able to produce an electron radiation in synchronism with the electromagnetic field and to transfer the electron beam kinetic energy to the plasma. This facility requires an advanced pulsed high voltage power supply (HVPS) with the following technical characteristics: variable output voltage up to 700 kV; variable pulse length in the range 5–50 μs; overshoot < 2%; rise time < 1 μs; voltage accuracy (including drop, ripple and stability) <0.1%. This paper describes the conceptual design and the technical solutions adopted to achieve the performance requested for the CARM HVPS.

  11. Conceptual design of pulsed high voltage and high precision power supply for a cyclotron auto-resonance maser (CARM) for plasma heating

    Energy Technology Data Exchange (ETDEWEB)

    Zito, Pietro, E-mail: pietro.zito@enea.it; Maffia, Giuseppe; Lampasi, Alessandro

    2015-10-15

    Highlights: • ENEA started a project to develop a cyclotron auto-resonance maser (CARM). • This facility requires an advanced pulsed high voltage power supply (HVPS). • The conceptual design answers to the performances requested for CARM HVPS. • The pulse transformer parameters were estimated according to IEEE standards. • PWM PID-based controller has been optimized to follow very fast rectangular pulses. - Abstract: Due to the high electron temperature during the plasma burning, both a higher power (>1 MW) and a higher frequency (up to 300 GHz) are required for plasma heating in future fusion experiments like DEMO. For this task, ENEA started a project to develop a cyclotron auto-resonance maser (CARM) able to produce an electron radiation in synchronism with the electromagnetic field and to transfer the electron beam kinetic energy to the plasma. This facility requires an advanced pulsed high voltage power supply (HVPS) with the following technical characteristics: variable output voltage up to 700 kV; variable pulse length in the range 5–50 μs; overshoot < 2%; rise time < 1 μs; voltage accuracy (including drop, ripple and stability) <0.1%. This paper describes the conceptual design and the technical solutions adopted to achieve the performance requested for the CARM HVPS.

  12. A Novel Approach to Power Circuit Breaker Design for Replacement of SF6

    Directory of Open Access Journals (Sweden)

    D. J. Telfer

    2004-01-01

    Full Text Available This contribution explores the role of PTFE ablation in enhancing current interruption for various background gases in high voltage circuit breakers. An assessment of the current interruption capability has been made in terms of the arcing duration and the contact gap length at which critical arc extinction is achieved. These observations are supported by measurements of the magnitude of extinction and re-ignition voltage peaks. Most previous and other current experimental work on gas filled circuit breaker design follows conventional wisdom in investigating arcing behaviours at elevated gas pressures (usually up to 6 bar. But in this work we concentrate on the effects of using low gas pressures (less than 1 bar in the presence of a close-fitting shield of ablatant polymer material (PTFE that surrounds the electrode assembly of an experimental high power circuit breaker. We demonstrate that for several different gases, arc extinction capability compares well under these conditions with SF6, suggesting that SF6 could be replaced entirely in this novel system by more environmentally friendly gases. Moreover, the critical contact gap lengths at extinction are only slightly greater than when using SF6 at 6 bar. Weight loss measurements from the ablatant shield suggest that a chemical puffer action is the most likely mechanism for achieving the observed arc extinctions in this system.

  13. Dielectric properties for SF6 and SF6 mixtures predicted from basic data

    International Nuclear Information System (INIS)

    Kline, L.E.; Davies, D.K.; Chen, C.L.; Chantry, P.J.

    1978-01-01

    α and eta, the ionization and attachment coefficients, and (E/N)*, the limiting breakdown electric field-to-gas density ratio, in SF 6 and SF 6 mixtures were calculated by numerically solving the Boltzmann equation for the electron energy distribution. The calculations require a knowledge of several electron collision cross sections. Published momentum transfer and ionization cross sections for SF 6 were used. Various attachment cross sections for SF 6 were measured by using electron beam techniques with mass spectrometric ion detection. A total cross section for electronic excitation of SF 6 was determined by comparing the predicted values of α, eta, and (E/N)* with measured values obtained from spatial current growth experiments in SF 6 in uniform fields over an extended range of E/N. With this self-consistent set of SF 6 cross sections, together with published He cross sections, it was then possible to predict the dielectric properties of SF 6 --He mixtures. Published experimental values of α for these mixtures lie between the values of α calculated with and without ionization of SF 6 by excited He atoms. Published experimental values of (E/N)* agree with the calculations to within 5%. 11 figures

  14. Decomposition of Potent Greenhouse Gases SF6, CF4 and SF5CF3 by Dielectric Barrier Discharge

    International Nuclear Information System (INIS)

    Zhang Renxi; Wang Jingting; Cao Xu; Hou Huiqi

    2016-01-01

    For their distinguished global warming potential (GWP100) and long atmosphere lifespan, CF 4 , SF 6 and SF 5 CF 3 were significant in the field of greenhouse gas research. The details of discharging character and the optimal parameter were discussed by using a Dielectric Barrier Discharge (DBD) reactor to decompose these potent greenhouse gases in this work. The results showed that SF 6 could be decomposed by 92% under the conditions of 5 min resident time and 3000 V applied voltage with the partial pressure of 2.0 kPa, 28.2 kPa, and 1.8 kPa for SF 6 , air and water vapor, respectively. 0.4 kPa CF 4 could be decomposed by 98.2% for 4 min resident time with 30 kPa Ar added. The decomposition of SF 5 CF 3 was much more effective than that of SF 6 and CF 4 and moreover, 1.3 kPa SF 5 CF 3 , discharged with 30 kPa O 2 , Ar and air, could not be detected when the resident time was 80 s, 40 s, and 120 s, respectively. All the results indicated that DBD was a feasible technique for the abatement of potent greenhouse gases. (paper)

  15. Numaerical simulation of a SF6 circuit-breaker arc

    International Nuclear Information System (INIS)

    Vergne, P.J.; Gonzalez, J.J.; Gleizes, A.

    1995-01-01

    The design and the validation of high-voltage circuit breaker require more and more physical models which take into account complex phenomenae. We present here a numerical simulation of an SF 6 arc established in a simplified geometry of a circuit breaker prototype. Our study deals specially with the turbulent flow, the boundary conditions of the arc roots on the electrodes, the influence of the electromagnetic strengths and the radiative transfer. The results concern a stationary state with fixed geometry and current intensity (I=2000 A)

  16. Negative corona current pulses in argon and in mixture argon with SF6

    International Nuclear Information System (INIS)

    Zahoranova, A.; Zahoran, M.; Bucek, A.; Cernak, M.; Bosko, J.

    2004-01-01

    Waveforms of the first negative current pulses in a short negative point-to plane gap in pure argon and argon with SF 6 admixture have been investigated with a nanosecond time resolution at a gas pressure 50 kPa as a function of applied gap voltage and content of SF 6 in the mixture. We have made an attempt to explain the differences in the discharge development in pure argon and in argon with admixture of SF 6 based on the observed changes of the pulse shape. The experimental results obtained will be discussed in context with existing computer simulation models (Authors)

  17. SF6 and the greenhouse effect

    International Nuclear Information System (INIS)

    Gjaerde, Anne Cathrine; Rein, Asgaut; Hegerberg, Rolf; Kulsetaas, John

    1997-01-01

    The gas SF 6 (sulfur hexafluoride) is much used as an insulation medium in electric switchgear and breakers. However, there has been some recent concern about the possible contribution of SF 6 to the global greenhouse effect. This report presents some collected facts about SF 6 emission. The concentration of SF 6 in the atmosphere is very low and will probably remain so until the end of the next century. Hence the contribution of SF 6 to the greenhouse effect is negligible. Most of the SF 6 emission comes from the magnesium and aluminium industries. In 1993, SF 6 emission from switchgear in the Norwegian distribution grid corresponded to only 0.2 per million of the CO 2 emission in Norway. But the quantity of SF 6 accumulated in electric switchgear is considerable. However, losing it to the atmosphere can be avoided by using recirculation or destruction systems for SF 6 in connection with maintenance and replacement of components. Norwegian climate policy aims at taking measures against SF 6 and other climate gases on a par with CO 2 . Taxation measures have been suggested for SF 6 . Atmospheric SF 6 does not influence the ozone layer. 3 refs., 8 figs

  18. High speed auto-charging system for condenser bank

    International Nuclear Information System (INIS)

    Mizuno, Yasunori; Bito, Fumio; Fujita, Kazuhiko; Sometani, Taro

    1987-01-01

    A current-control type high-speed charging system, which is intended for auto-charging of the condenser bank, is developed. Moreover, the system can also serve to compensate the current leakage from the condenser bank so that the charged voltage can be kept constant. The system consists of a sequence circuit, a charging current control circuit (or auto-charging circuit) and a charging circuit. The auto-charging circuit is characterized by the use of a triac to control the current. The current, controlled by the circuit, is supplied to the condenser bank through a step-up transformer and voltage doubler rectifier circuit. It is demonstrated that the use of the high-speed auto-charging circuit can largely decrease the required charging time, compared to constant voltage charging. In addition, the compensation function is shown to serve effectively for maintaining a constant voltage after the completion of charging. The required charging time is decreases as the charging current increases. The maximum charging current is decided by the rating of the traic and the current rating of the rectifier diode in the secondary circuit. Major components of these circuits have decreased impedances to minimize the effect of noise, so that the possibility of an accident can be eliminated. Other various improvements are made in the grounding circuit and the charging protection circuit in order to ensure safety. (Nogami, K.)

  19. High voltage performance of BARC-TIFR Pelletron Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Surendran, P.; Ansari, Q.N.; Nair, J.P., E-mail: surendra@tifr.res.in [Nuclear Physics Division, Bhabha Atomic Research Centre, Mumbai (India); and others

    2014-07-01

    The 14 UD Pelletron Accelerator at TIFR, Mumbai is operational since its inception in 1988. It was decided to impart enough time for high voltage conditioning to achieve higher operational voltage. Prior to this, comprehensive works such as replacing all the sputter ion pumps and Titanium sublimation pumps across the accelerator tube with new or refurbished ones and replacement of Alumina balls in the SF{sub 6} drier with fresh balls were carried out. High voltage conditioning of each module was done. Further conditioning of two modules at a time in overlapping mode improved the terminal voltage. As a result of this rigorous conditioning Terminal voltage of 12.6 MV was achieved and beam has been delivered to users at 12 MV terminal. Details of this effort will be presented in this paper. (author)

  20. High voltage performance of BARC-TIFR Pelletron Accelerator

    International Nuclear Information System (INIS)

    Surendran, P.; Ansari, Q.N.; Nair, J.P.

    2014-01-01

    The 14 UD Pelletron Accelerator at TIFR, Mumbai is operational since its inception in 1988. It was decided to impart enough time for high voltage conditioning to achieve higher operational voltage. Prior to this, comprehensive works such as replacing all the sputter ion pumps and Titanium sublimation pumps across the accelerator tube with new or refurbished ones and replacement of Alumina balls in the SF_6 drier with fresh balls were carried out. High voltage conditioning of each module was done. Further conditioning of two modules at a time in overlapping mode improved the terminal voltage. As a result of this rigorous conditioning Terminal voltage of 12.6 MV was achieved and beam has been delivered to users at 12 MV terminal. Details of this effort will be presented in this paper. (author)

  1. Dynamics of infrared multiphonon dissociation of SF6 by molecular beam method

    International Nuclear Information System (INIS)

    Grant, E.R.; Coggiola, M.J.; Lee, Y.T.; Schulz, P.A.; Shen, Y.R.

    1977-01-01

    A crossed molecular beam apparatus has been adapted to study the dynamics of excitation and dissociation of polyatomic molecules in intense IR laser fields. Initial experiments have involved the study of the dissociation of SF 6 by CO 2 laser radiation at 10.6 μm. A molecular beam of SF 6 was formed by supersonic expansion using three stages of differential pumping. A grating tuned pulsed CO 2 TEA laser was used as the excitation source. The laser beam was focused by a 25 cm focal length ZnSe lens, and crossed the molecular beam near its focal point. The fragments produced by multiphonon dissociation of SF 6 within the small interaction region were detected as a function of recoil angle and velocity. (Auth.)

  2. Comprehensive Study of SF_6/O_2 Plasma Etching for Mc-Silicon Solar Cells

    International Nuclear Information System (INIS)

    Li Tao; Zhou Chun-Lan; Wang Wen-Jing

    2016-01-01

    The mask-free SF_6/O_2 plasma etching technique is used to produce surface texturization of mc-silicon solar cells for efficient light trapping in this work. The SEM images and mc-silicon etching rate show the influence of plasma power, SF_6/O_2 flow ratios and etching time on textured surface. With the acidic-texturing samples as a reference, the reflection and IQE spectra are obtained under different experimental conditions. The IQE spectrum measurement shows an evident increase in the visible and infrared responses. By using the optimized plasma power, SF_6/O_2 flow ratios and etching time, the optimal efficiency of 15.7% on 50 × 50 mm"2 reactive ion etching textured mc-silicon silicon solar cells is achieved, mostly due to the improvement in the short-circuit current density. The corresponding open-circuit voltage, short-circuit current density and fill factor are 611 mV, 33.6 mA/cm"2, 76.5%, respectively. It is believed that such a low-cost and high-performance texturization process is promising for large-scale industrial silicon solar cell manufacturing. (paper)

  3. Theoretical study of OCCHCN as a potential alternative insulation gas for SF6

    Directory of Open Access Journals (Sweden)

    Zhiguo Chen

    2017-01-01

    Full Text Available Cyanoketene (OCCHCN has been reported as a potential alternative insulation gas for SF6 in Patent US0135817. Stationary point equilibrium geometries on the ground state have been optimized at the B3LYP/6-311+G(d,p level, and the harmonic vibration frequencies are calculated at the same level. The HOMO-LUMO energy gaps (Eg, ionization potentials (IP, and electron affinities (EA of the studied molecules are obtained. The minimum energy path (MEP is obtained by the intrinsic reaction coordinate (IRC theory, and the energetic information is further refined by QCISD(T (single-point method. The results show that OCCHCN can be used as SF6 alternative insulation gas in high voltage equipment according to potential energy surface analysis. As the isomerization and the cleavage reactions potential barriers are lower than the Eg and IP values, resulting in OCCHCN is not easy to be ionized and excited.

  4. Two-temperature thermodynamic and transport properties of SF6–Cu plasmas

    International Nuclear Information System (INIS)

    Wu, Yi; Chen, Zhexin; Yang, Fei; Rong, Mingzhe; Sun, Hao; Cressault, Yann; Murphy, Anthony B; Guo, Anxiang; Liu, Zirui

    2015-01-01

    SF 6 and Cu are widely adopted in electrical equipment as a dielectric medium and for conductive components, respectively. SF 6 –Cu plasmas are frequently formed, particularly in high-voltage circuit breaker arcs and fault current arcs, due to erosion of the Cu components. In this paper, calculated values of the thermodynamic and transport properties of plasmas in SF 6 –Cu mixtures are presented for both thermal equilibrium and non-equilibrium conditions. The composition is determined by the two-temperature Saha equation and Guldberg–Waage equation in the form derived by van de Sanden. The composition and the thermodynamic properties are evaluated through a classical statistical mechanics approach. For the transport coefficients, the simplified Chapman–Enskog method developed by Devoto, which decouples the electrons and heavy species, has been applied using the most recent collision integrals. The thermodynamic and transport properties are calculated for different electron temperatures (300–40 000 K), ratios of electron to heavy-species temperature (1–10), pressures (0.1–10 atm) and copper molar proportions (0–50%). It is found that deviations from thermal equilibrium strongly affect the thermodynamic and transport properties of the SF 6 –Cu plasmas. Further, the presence of copper has different effects on some of the properties for plasmas in and out of thermal equilibrium. The main reason for these changes is that dissociation reactions are delayed for non-thermal equilibrium plasmas, which in turn influences the ionization reactions that occur. (paper)

  5. Parametric investigation on the effect of nitrogen to reduce SF6 content in spark gap

    Science.gov (United States)

    Raj, Avinash; Khaidir, Nur; Ishak, Sanuri; Ghani, Basri Abdul; Chakrabarty, Chandan; Permal, Navitharshaani; Ahmad, Harizan

    2017-03-01

    Almost all the MV and HV switchgears used by power utilities for interrupting faults are Sulphur Hexaflouride SF6 gas circuit breakers as this gas has the best dielectric properties to quench the onset of an arc in the event of fault. However due to strong dissociating properties of this gas when in contact with air that can release fluorine into the atmosphere, the Kyoto protocol has mandated to reduce the usage of SF6 in the future. SF6 is a greenhouse gas and it's about 3000 more severe than CO2. And that's the reason for replacing this gas. A close match in the quenching properties to SF6 that is now being intensively researched is nitrogen N2. This gas is considered to be an inert gas, and its release into the atmosphere has no harmful effects (except for asphyxiation - which can be easily handled with awareness). As the need for a replacement of SF6 becomes critical in the near future, the urgency to find the right gas is immediate. Hence the proposed work in this paper is to make a comprehensive parametric investigation of N2 gas in vacuum spark-gap. The spark-gap is chosen due to flexibility in changing the gap distance and easily be housed in vacuum. The parameters to be investigated are pure N2 and N2/ SF6 mix. The settling-time of the electrical break-down voltage and current are measured using voltage probe and Pearson probe. This time is paramount as it determines the speed of breaking the circuit. A faster breaking time ensures the safety of other HV equipment in the circuit. A comparative study between the various parameters will be conducted to obtain the best recipe (gas mix and gap distance) that gives the shortest settling time the breakdown using N2/ SF6/Mixture gas was successfully conducted and a Paschen curve has been established.

  6. Optimizing the switching time for 400 kV SF6 circuit breakers

    Science.gov (United States)

    Ciulica, D.

    2018-01-01

    This paper presents real-time voltage and current analysis for optimizing the wave switching point of the circuit breaker SF6. Circuit Breaker plays an important role in power systems. It provides protection for equipment in embedded stations in transport networks. SF6 Circuit Breaker is very important equipment in Power Systems, which is used for up to 400 kV due to its excellent performance. The controlled switching is used to eliminate transient modes and electrodynamic and dielectric charges in the network at manual switching of capacitor, shunt reactors and power transformers. These effects reduce the reliability and lifetime of the equipment installed on the network, or may lead to erroneous protection.

  7. The development of high-voltage repetitive low-jitter corona stabilized triggered switch

    Science.gov (United States)

    Geng, Jiuyuan; Yang, Jianhua; Cheng, Xinbing; Yang, Xiao; Chen, Rong

    2018-04-01

    The high-power switch plays an important part in a pulse power system. With the trend of pulse power technology toward modularization, miniaturization, and accuracy control, higher requirements on electrical trigger and jitter of the switch have been put forward. A high-power low-jitter corona-stabilized triggered switch (CSTS) is designed in this paper. This kind of CSTS is based on corona stabilized mechanism, and it can be used as a main switch of an intense electron-beam accelerator (IEBA). Its main feature was the use of an annular trigger electrode instead of a traditional needle-like trigger electrode, taking main and side trigger rings to fix the discharging channels and using SF6/N2 gas mixture as its operation gas. In this paper, the strength of the local field enhancement was changed by a trigger electrode protrusion length Dp. The differences of self-breakdown voltage and its stability, delay time jitter, trigger requirements, and operation range of the switch were compared. Then the effect of different SF6/N2 mixture ratio on switch performance was explored. The experimental results show that when the SF6 is 15% with the pressure of 0.2 MPa, the hold-off voltage of the switch is 551 kV, the operating range is 46.4%-93.5% of the self-breakdown voltage, the jitter is 0.57 ns, and the minimum trigger voltage requirement is 55.8% of the peak. At present, the CSTS has been successfully applied to an IEBA for long time operation.

  8. EPA's SF6 Emission Reduction Partnership: Maximizing the Benefits of SF6 Emission Reductions for Electric Utilities

    National Research Council Canada - National Science Library

    Blackman, Jerome; Kantamaneni, Ravi

    2004-01-01

    .... Under ideal conditions, SF6 would remain contained within transmission equipment. In reality, however, SF6 is inadvertently emitted into the atmosphere as leaks develop during various stages of the equipment's life cycle...

  9. Analysis of the characteristics of DC nozzle arcs in air and guidance for the search of SF6 replacement gas

    Science.gov (United States)

    Liu, J.; Zhang, Q.; Yan, J. D.; Zhong, J.; Fang, M. T. C.

    2016-11-01

    It is shown that the arc model based on laminar flow cannot predict satisfactorily the voltage of an air arc burning in a supersonic nozzle. The Prandtl mixing length model (PML) and a modified k-epsilon turbulence model (MKE) are used to introduce turbulence enhanced momentum and energy transport. Arc voltages predicted by these two turbulence models are in good agreement with experiments at the stagnation pressure (P 0) of 10 bar. The predicted arc voltages by MKE for P 0  =  13 bar and 7 bar are in better agreement with experiments than those predicted by PML. MKE is therefore a preferred turbulence model for an air nozzle arc. There are two peaks in ρC P of air at 4000 K and 7000 K due, respectively, to the dissociation of oxygen and that of nitrogen. These peaks produce corresponding peaks in turbulent thermal conductivity, which results in very broad radial temperature profile and a large arc radius. Thus, turbulence indirectly enhances axial enthalpy transport, which becomes the dominant energy transport process for the overall energy balance of the arc column at high currents. When the current reduces, turbulent thermal conduction gradually becomes dominant. The temperature dependence of ρC P has a decisive influence on the radial temperature profile of a turbulent arc, thus the thermal interruption capability of a gas. Comparison between ρC P for air and SF6 shows that ρC P for SF6 has peaks below 4000 K. This renders a distinctive arc core and a small arc radius for turbulent SF6, thus superior arc quenching capability. It is suggested, for the first time, that ρC P provides guidance for the search of a replacement switching gas for SF6.

  10. The Application of Auto-Disturbance Rejection Control Optimized by Least Squares Support Vector Machines Method and Time-Frequency Representation in Voltage Source Converter-High Voltage Direct Current System.

    Science.gov (United States)

    Liu, Ying-Pei; Liang, Hai-Ping; Gao, Zhong-Ke

    2015-01-01

    In order to improve the performance of voltage source converter-high voltage direct current (VSC-HVDC) system, we propose an improved auto-disturbance rejection control (ADRC) method based on least squares support vector machines (LSSVM) in the rectifier side. Firstly, we deduce the high frequency transient mathematical model of VSC-HVDC system. Then we investigate the ADRC and LSSVM principles. We ignore the tracking differentiator in the ADRC controller aiming to improve the system dynamic response speed. On this basis, we derive the mathematical model of ADRC controller optimized by LSSVM for direct current voltage loop. Finally we carry out simulations to verify the feasibility and effectiveness of our proposed control method. In addition, we employ the time-frequency representation methods, i.e., Wigner-Ville distribution (WVD) and adaptive optimal kernel (AOK) time-frequency representation, to demonstrate our proposed method performs better than the traditional method from the perspective of energy distribution in time and frequency plane.

  11. The Application of Auto-Disturbance Rejection Control Optimized by Least Squares Support Vector Machines Method and Time-Frequency Representation in Voltage Source Converter-High Voltage Direct Current System.

    Directory of Open Access Journals (Sweden)

    Ying-Pei Liu

    Full Text Available In order to improve the performance of voltage source converter-high voltage direct current (VSC-HVDC system, we propose an improved auto-disturbance rejection control (ADRC method based on least squares support vector machines (LSSVM in the rectifier side. Firstly, we deduce the high frequency transient mathematical model of VSC-HVDC system. Then we investigate the ADRC and LSSVM principles. We ignore the tracking differentiator in the ADRC controller aiming to improve the system dynamic response speed. On this basis, we derive the mathematical model of ADRC controller optimized by LSSVM for direct current voltage loop. Finally we carry out simulations to verify the feasibility and effectiveness of our proposed control method. In addition, we employ the time-frequency representation methods, i.e., Wigner-Ville distribution (WVD and adaptive optimal kernel (AOK time-frequency representation, to demonstrate our proposed method performs better than the traditional method from the perspective of energy distribution in time and frequency plane.

  12. Uv laser triggering of high-voltage gas switches

    International Nuclear Information System (INIS)

    Woodworth, J.R.; Frost, C.A.; Green, T.A.

    1982-01-01

    Two different techniques are discussed for uv laser triggering of high-voltage gas switches using a KrF laser (248 nm) to create an ionized channel through the dielectric gas in a spark gap. One technique uses an uv laser to induce breakdown in SF 6 . For this technique, we present data that demonstrate a 1-sigma jitter of +- 150 ps for a 0.5-MV switch at 80% of its self-breakdown voltage using a low-divergence KrF laser. The other scheme uses additives to the normal dielectric gas, such as tripropylamine, which are selected to undergo resonant two-step ionization in the uv laser field

  13. Leak detection of SF6 gas pressure vessel safety devices at BARC-TIFR Pelletron accelerator

    International Nuclear Information System (INIS)

    Ninawe, N.G.; Sharma, S.C.; Nair, J.P.; Sparrow, H.; Bolar, P.C.; Gudekar, P.V.; Mahapatra, S.; Vishwakarma, R.S.; Ramjilal; Matkar, U.V.; Gore, J.A.; Gupta, A.K.

    2015-01-01

    Pelletron accelerator is in operation since last more than 26 years. To achieve desired voltage gradient SF6 gas of about 20 tons is used to have 75-80 psig pressure in main accelerator tank. During accelerator tank maintenance gas is transferred to four storage tanks, kept in open space in the vicinity of sea. Recently refurbishment and retrofitting of four storage tanks was carried out which includes the installation of new drift space, rupture disc assembly, relief valves and manual valves along with civil and painting work. All components to be installed were tested for high pressure. Helium gas sniffer technique was used to check micro leaks for new joints for all components before installing for storage tanks. Subsequently, the tanks were tested up to 90 psig SF6 gradually in succession. No pressure drop was observed in storage tanks. This work was carried out as per recommendation of the then particle accelerator committee (PASC). (author)

  14. Influence of condensed species on thermo-physical properties of LTE and non-LTE SF6-Cu mixture

    Science.gov (United States)

    Chen, Zhexin; Wu, Yi; Yang, Fei; Sun, Hao; Rong, Mingzhe; Wang, Chunlin

    2017-10-01

    SF6-Cu mixture is frequently formed in high-voltage circuit breakers due to the electrode erosion and metal vapor diffusion. During the interruption process, the multiphase effect and deviation from local thermal equilibrium (non-LTE assumption) can both affect the thermo-physical of the arc plasma and further influence the performance of circuit breaker. In this paper, thermo-physical properties, namely composition, thermodynamic properties and transport coefficients are calculated for multiphase SF6-Cu mixture with and without LTE assumption. The composition is confirmed by combining classical two-temperature mass action law with phase equilibrium condition deduced from second law of thermodynamics. The thermodynamic properties and transport coefficients are calculated using the multiphase composition result. The influence of condensed species on thermo-physical properties is discussed at different temperature, pressure (0.1-10 atm), non-equilibrium degrees (1-10), and copper molar proportions (0-50%). It is found that the multiphase effect has significant influence on specific enthalpy, specific heat and heavy species thermal conductivity in both LTE and non-LTE SF6-Cu system. This paper provides a more accurate database for computational fluid dynamic calculation.

  15. Electron scattering cross sections for SF6 and SF5CF3 at intermediate and high energies (100-10000 eV)

    International Nuclear Information System (INIS)

    Limao-Vieira, P.; Blanco, F.; Oller, J.C.; Munoz, A.; Perez, J.M.; Vinodkumar, M.; Garcia, G.; Mason, N.J.

    2005-01-01

    A modified experimental apparatus with improved angular resolution and stability has been used to measure the total electron scattering cross sections for SF 6 and SF 5 CF 3 in the energy range of 100-5000 eV. A detailed analysis of the experimental error sources is provided. The experimental results are compared with integral elastic and inelastic cross sections calculated using the independent atom model approximation and a modified single-center additivity rule for electron energies ranging from 1 to 10,000 eV. The accuracy of these approximations method is discussed through a comparison with the experimental results. Previous cross-sectional data for SF 6 are compared with the present theoretical and experimental results. For SF 5 CF 3 , we present the first electron scattering cross-sectional data for the 100-10,000 eV energy range, as well as the first empirical determination of the molecular polarizability

  16. Influence of condensed species on thermo-physical properties of LTE and non-LTE SF6–Cu mixture

    International Nuclear Information System (INIS)

    Chen, Zhexin; Wu, Yi; Yang, Fei; Sun, Hao; Rong, Mingzhe; Wang, Chunlin

    2017-01-01

    SF 6 –Cu mixture is frequently formed in high-voltage circuit breakers due to the electrode erosion and metal vapor diffusion. During the interruption process, the multiphase effect and deviation from local thermal equilibrium (non-LTE assumption) can both affect the thermo-physical of the arc plasma and further influence the performance of circuit breaker. In this paper, thermo-physical properties, namely composition, thermodynamic properties and transport coefficients are calculated for multiphase SF 6 –Cu mixture with and without LTE assumption. The composition is confirmed by combining classical two-temperature mass action law with phase equilibrium condition deduced from second law of thermodynamics. The thermodynamic properties and transport coefficients are calculated using the multiphase composition result. The influence of condensed species on thermo-physical properties is discussed at different temperature, pressure (0.1–10 atm), non-equilibrium degrees (1–10), and copper molar proportions (0–50%). It is found that the multiphase effect has significant influence on specific enthalpy, specific heat and heavy species thermal conductivity in both LTE and non-LTE SF 6 –Cu system. This paper provides a more accurate database for computational fluid dynamic calculation. (paper)

  17. Laser excitation of SF6: spectroscopy and coherent pulse propagation effects

    International Nuclear Information System (INIS)

    Cantrell, C.D.; Makarov, A.A.; Louisell, W.H.

    1978-01-01

    Recent theoretical studies of coherent propagation effects in SF 6 and other polyatomic molecules are summarized beginning with an account of relevant aspects of the high-resolution spectroscopy of the ν 3 band of SF 6 . A laser pulse propagating in a molecular gas can acquire new frequencies which were not initially present in the pulse, and, in fact, a wave is coherently generated at the frequency of every molecular transition accessible from the initial molecular energy levels. The possible consequences of coherent generation of sidebands for the multiple-photon excitation of SF 6 and other polyatomic molecules are discussed

  18. Controlled auto-ignition characteristics of methane-air mixture in a rapid intake compression and expansion machine

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Gyubaek; Jeong, Dongsoo [Engine Research Team, Eco-Machinery Research Division, Korea Institute of Machinery and Materials, 104 Sinseongno, Yuseong-gu, Daejeon 305-701 (Korea); Moon, Gunfeel [Department of Clean Environmental system, University of Science and Technology, 52 Eoeun-dong, Yuseong-gu, Daejeon (Korea); Bae, Choongsik [Engine Laboratory, Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, 373-1 GuSeong-Dong, Yuseong-Gu, Daejeon 305-701 (Korea)

    2010-10-15

    The characteristics of controlled auto-ignition (CAI) were investigated with a methane-air mixture and simulated residual gas, that represents internal exhaust gas recirculation (IEGR). Supply systems were additionally installed on the conventional rapid compression machine (RCM), and this modified machine - a rapid intake compression and expansion machine (RICEM) - was able to simulate an intake stroke for the evaluation of controlled auto-ignition with fuel-air mixture. The fuel-air mixture and the simulated residual gas were introduced separately into the combustion chamber through the spool valves. Various IEGR rates and temperatures of the IEGR gas were tested. The initial reaction and the development in controlled auto-ignition combustion were compared with spark-ignited combustion by visualization with a high-speed digital camera. Under the controlled auto-ignition operation, multi-point ignition and faster combustion were observed. With increasing the temperature of IEGR gas, the auto-ignition timing was advanced and burning duration was shortened. The higher rate of IEGR had the same effects on the combustion of the controlled auto-ignition. However, this trend was reversed with more than 47 per cent of IEGR. (author)

  19. Statistical characteristics of transient enclosure voltage in ultra-high-voltage gas-insulated switchgear

    Science.gov (United States)

    Cai, Yuanji; Guan, Yonggang; Liu, Weidong

    2017-06-01

    Transient enclosure voltage (TEV), which is a phenomenon induced by the inner dielectric breakdown of SF6 during disconnector operations in a gas-insulated switchgear (GIS), may cause issues relating to shock hazard and electromagnetic interference to secondary equipment. This is a critical factor regarding the electromagnetic compatibility of ultra-high-voltage (UHV) substations. In this paper, the statistical characteristics of TEV at UHV level are collected from field experiments, and are analyzed and compared to those from a repeated strike process. The TEV waveforms during disconnector operations are recorded by a self-developed measurement system first. Then, statistical characteristics, such as the pulse number, duration of pulses, frequency components, magnitude and single pulse duration, are extracted. The transmission line theory is introduced to analyze the TEV and is validated by the experimental results. Finally, the relationship between the TEV and the repeated strike process is analyzed. This proves that the pulse voltage of the TEV is proportional to the corresponding breakdown voltage. The results contribute to the definition of the standard testing waveform of the TEV, and can aid the protection of electronic devices in substations by minimizing the threat of this phenomenon.

  20. A novel method to decompose two potent greenhouse gases: Photoreduction of SF6 and SF5CF3 in the presence of propene

    International Nuclear Information System (INIS)

    Huang Li; Shen Yan; Dong Wenbo; Zhang Renxi; Zhang Jianliang; Hou Huiqi

    2008-01-01

    SF 5 CF 3 and SF 6 are the most effective greenhouse gases on a per molecule basis in the atmosphere. Original laboratory trial for photoreduction of them by use of propene as a reactant was performed to develop a novel technique to destroy them. The highly reductive radicals produced during the photolysis of propene at 184.9 nm, such as ·CH 3 , ·C 2 H 3 , and ·C 3 H 5 , could efficiently decompose SF 6 and SF 5 CF 3 to CH 4 , elemental sulfur and trace amounts of fluorinated organic compounds. It was further demonstrated that the destruction and removal efficiency (DRE) of SF 5 X (X represented F or CF 3 ) was highly dependent on the initial propene-to-SF 5 X ratio. The addition of certain amounts of oxygen and water vapor not only enhanced the DRE but avoided the generation of deposits. In both systems, employment nitrogen as dilution gas lessened the DRE slightly. Given the advantage of less toxic products, the technique might contribute to SF 5 X remediation

  1. Effects of SF$_{6}$ on the avalanche mode operation of a real-sized double-gap resistive plate chamber for the Compact Muon Solenoid experiment

    CERN Document Server

    Ahn Sung Hwan; Hong, B; Hong, S J; Ito, M; Kim, B I; Kim, J H; Kim, Y J; Kim, Y U; Koo, D G; Lee, H W; Lee, K B; Lee, K S; Lee, S J; Lim, J K; Moon, D H; Nam, S K; Park, S; Park, W J; Rhee, J T; Ryu, M S; Shim, H H; Sim, K S; Kang, T I

    2005-01-01

    We present the design and the test, results for a real-sized prototype resistive plate chamber by using cosmic-ray muons for the forward region of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC). In particular, we investigate the effects of adding SF/sub 6/ to the gas mixture for the avalanche mode operation of a resistive plate chamber. A small fraction of SF/sub 6/ is very effective in suppressing streamer signals in a resistive plate chamber. The shapes of the muon detection efficiency and the muon cluster size remain similar, but are shifted to higher operating voltage by SF/sub 6/. The noise cluster rate and size are not influenced by SF/sub 6/.

  2. Photodegradation of SF6 on polyisoprene surface: Implication on elimination of toxic byproducts

    International Nuclear Information System (INIS)

    Song Xiaoxiao; Liu Xingang; Ye Zhaolian; He Jincong; Zhang Renxi; Hou, Huiqi

    2009-01-01

    Photodegradation of SF 6 was performed on the surface of polyisoprene (PI) based on a brand new mechanism of 'controlled release of radicals'. Effective decomposition of SF 6 (60% of SF 6 was degraded in 4 h) was achieved due to the highly reductive radicals (mainly allylic radicals and excited C=C bond) which were generated from the photolysis of PI. No toxic fluoride was detected by FT-IR. The PI irradiated for 200 h in SF 6 circumstance was examined by XPS to be doped with fluorine and sulfur. Fouling due to photoinitiated polymerization on UV lamp was avoided because the radicals were released slowly. Photolysis of SF 6 in pure argon with the presence of irradiated PI showed kinetics of pseudo-first-order reaction and the degradation rate constant was 5.16 x 10 -5 s -1 . Factors which may affect the photolysis process such as introduction of O 2 and H 2 O were also examined.

  3. Theoretical investigation of the decay of an SF6 gas-blast arc using a two-temperature hydrodynamic model

    International Nuclear Information System (INIS)

    Wang Weizong; Rong Mingzhe; Yan, Joseph D; Spencer, Joseph W; Murphy, Anthony B

    2013-01-01

    The behaviour of a decaying SF 6 arc, which is representative of the approach to the final current-zero state of switching arcs in a high-voltage circuit breaker, is theoretically investigated by a two-temperature hydrodynamic model, taking into account the possible departure of the plasma state from local thermodynamic equilibrium (LTE). The model couples the plasma flow with electromagnetic fields in a self-consistent manner. The electrons and heavy species are assumed to have different temperatures. The species composition, thermodynamic properties and transport coefficients of the plasma under non-LTE conditions are calculated from fundamental theory. The model is then applied to a two-dimensional axisymmetric SF 6 arc burning in a supersonic nozzle under well-controlled conditions; for this configuration, experimental results are available for comparison. The effect of turbulence is considered using the Prandtl mixing-length model. The edge absorption of the radiation emitted by the arc core is taken into account by a modified net emission coefficient approach. The complete set of conservation equations is discretized and solved using the finite volume method. The evolution of electron and heavy-particle temperatures and the total arc resistance, along with other physical quantities, is carefully analysed and compared with those of the LTE case. It is demonstrated that the electron and heavy-particle temperature diverge at all times in the plasma-cold-flow interaction region, in which strong gas flow exists, and further in the transient current-zero period, in which case the collision energy exchange is ineffective. This study quantitatively analyses the energy exchange mechanisms between electrons and heavy particles in the high-pressure supersonic SF 6 arcs and provides the foundation for further theoretical investigation of transient SF 6 arc behaviour as the current ramps down to zero in gas-blast circuit breakers.

  4. Measurement of the figure of merit M for 1-C3F6/SF6 mixtures

    DEFF Research Database (Denmark)

    Christensen, Jørn Erik Berril; McAllister, Iain Wilson

    1997-01-01

    High precision measurements of the linear part of the Paschen curve are reported for 1-C3F6/SF6 mixtures. From these measurements, values for the pressure-reduced limiting electric field strength (E/p)lim and the associated figure of merit M are derived. These two parameters can be used to charac......High precision measurements of the linear part of the Paschen curve are reported for 1-C3F6/SF6 mixtures. From these measurements, values for the pressure-reduced limiting electric field strength (E/p)lim and the associated figure of merit M are derived. These two parameters can be used...

  5. Measurement ot the switching over-voltages at the disconnection of the high voltage shunt reactors in the Romanian power system

    Energy Technology Data Exchange (ETDEWEB)

    Stroica, Paul Constantin; Merfu, Ion; Stroica, Mihail; Merfu, Marius; Cojocaru, Florian; Stefan, Dinu; Cojocaru, Mihai

    2010-09-15

    The paper presents the measurements of the switching over-voltages made in the Romanian Power System, at the 400/220/110 kV Urechesti substation at the disconnection of a 400 kV, 100 MVAr shunt reactor type DFAL, Siemens, Germany, in 3 consecutive versions. The first one is for shunt reactor controlled by live-tank oil circuit breaker, the second one is for shunt reactor controlled by SF6 circuit breaker, and the third one is for shunt reactor controlled by SF6 circuit breaker and synchronize device.

  6. Expansion of the high-voltage direct current transmission systems; Netzausbau mit Hochspannungs-Gleichstrom-Uebertragung

    Energy Technology Data Exchange (ETDEWEB)

    Spahic, Ervin; Benz, Thomas; Goerner, Raphael; Sass, Florian [ABB AG, Mannheim (Germany)

    2012-12-15

    In September 2010 the German federal government announced its energy concept for an environmentally friendly, reliable and affordable energy supply. This concept describes a ''path into the era of renewable energy'' up to the year 2050, with electricity production from photovoltaics and wind power taking centre stage. Since the expansion of renewable energy production is mainly taking place in the North (wind power) and the South (PV), this poses a great challenge to the electricity networks. It necessitates the expansion of power transmission systems, notably for transporting electricity generated by wind power in the North to the consumer centres in Western and Southern Germany. However, progress to this end has been very slow. For this reason a technical question now presents itself, namely whether high-voltage direct current technology could possibly offer a solution to the electricity transport problems associated with the energy turnaround.

  7. Electronic Current Transducer (ECT) for high voltage dc lines

    Science.gov (United States)

    Houston, J. M.; Peters, P. H., Jr.; Summerayes, H. R., Jr.; Carlson, G. J.; Itani, A. M.

    1980-02-01

    The development of a bipolar electronic current transducer (ECT) for measuring the current in a high voltage dc (HVDC) power line at line potential is discussed. The design and construction of a free standing ECT for use on a 400 kV line having a nominal line current of 2000 A is described. Line current is measured by a 0.0001 ohm shunt whose voltage output is sampled by a 14 bit digital data link. The high voltage interface between line and ground is traversed by optical fibers which carry digital light signals as far as 300 m to a control room where the digital signal is converted back to an analog representation of the shunt voltage. Two redundant electronic and optical data links are used in the prototype. Power to operate digital and optical electronics and temperature controlling heaters at the line is supplied by a resistively and capacitively graded 10 stage cascade of ferrite core transformers located inside the hollow, SF6 filled, porcelain support insulator. The cascade is driven by a silicon controlled rectifier inverter which supplies about 100 W of power at 30 kHz.

  8. Micro controller application as x-ray machine's high voltage controller

    International Nuclear Information System (INIS)

    Wiranto Budi Santoso; Beny Syawaludin

    2010-01-01

    The micro controller application as x-ray machine's high voltage controller has been carried out. The purpose of this micro controller application is to give an accurate high voltage supply to the x-ray tube so that the x ray machine could produce the result as expected. The micro controller based X-ray machine's high voltage controller receives an input voltage from the keypad. This input value is displayed in the LCD (Liquid Crystal Display) screen. Then micro controller uses this input data to drive the stepper motor. The stepper motor adjusts the high voltage auto transformer's output according to the input value. The micro controller is programmed using BASCOM-B051 compiler. The test results show that the stepper motor could rotate according to an input value. (author)

  9. Study of protection devices against the effects of electric discharges inside a very high voltage generator: the Vivitron accelerator

    International Nuclear Information System (INIS)

    Nolot, E.

    1996-01-01

    The Vivitron tandem is a large electrostatic accelerator comprising a Van de Graaff generator designed to reach terminal voltages of around 30 MV. The machine is limited at rather lower nominal voltages (about 20 MV) due to the sensitivity of the insulating column structure to transient overvoltages. These are induced by electrical discharges in compressed SF 6 . This thesis first aims at analysing the fundamental reasons of electrical discharges in order to limit the probability of their occurrence. Then we simulate the transient overvoltages induced and present some improvements which may lead to a stable behaviour of the Vivitron at nominal voltages higher than 20 MV. Initially we deduce discharge onset voltages and actual breakdown field limitations in the different gap geometries from analysis of possible breakdown mechanisms in compressed SF 6 . In a second part, some electrical characteristics of the insulating column structure are measured at high voltage. Fast rising oscillating waves induced by sparking in the Vivitron, along with the associated energies,are determined in the third part. The last part deals with new surge protections of the insulating column structure. Spark gaps with precise onset voltage and optimized shielding electrodes are discussed. ZnO-based varistors designed for operation at very high fields have also been developed in order to reduce transient overvoltage values. (author)

  10. Technical and economic evaluation of voltage level in transmission network expansion planning using GA

    International Nuclear Information System (INIS)

    Jalilzadeh, S.; Kazemi, A.; Shayeghi, H.; Madavi, M.

    2008-01-01

    Transmission network expansion planning is an important part of power system planning. Its task is to determine an optimal network configuration according to load growth. It determines where, when and how many new transmission lines should be installed. Up to now, various methods have been presented to solve the static transmission network expansion planning (STNEP) problem, but in all of these methods, the STNEP problem has been solved regardless of voltage level of the lines. In this paper, due to different voltage levels in the transmission network, which cause different annual losses, STNEP has been studied considering the voltage level of the transmission lines and the network loss using the genetic algorithm (GA). Finally, the proposed idea has been examined on Garvers 6 bus network. The results show that considering the loss in a network with different voltage levels decreases the operational costs considerably, and the network satisfies the requirement of delivering electric power more safely and reliably to load centers

  11. Self-focusing in SF6

    International Nuclear Information System (INIS)

    Ackerhalt, J.R.; Galbraith, H.W.

    1981-01-01

    It is shown by explicit calculation of previously published quasicontinuum model that the molecular susceptibility rapidly approaches zero as higher excited states of the molecule become populated. Hence the overtones of the ν 3 -pumped mode are totally responsible for the self focusing effects in SF 6 . The ν 3 ladder contribution to the susceptibility is calculated. The vibrational model is a classical triply degenerate anharmonic oscillator in the Cartesian basis with the anharmonicity parameters chosen to be consistent with the latest spectroscopic analysis of the 3ν 3 overtone spectrum. The rotational structure is represented by a distribution of these oscillators where the distribution is chosen to correspond to the spectrum of the ν 3 fundamental. Good agreement is found with the 300 0 in self-focusing data of Nowak and Ham at CO 2 P(28), P(20) and P(10) in SF 6

  12. Development of large high-voltage pressure insulators for the Princeton TFTR [Tokamak Fusion Test Reactor] flexible transmission lines

    International Nuclear Information System (INIS)

    Scalise, D.T.; Fong, E.; Haughian, J.; Prechter, R.

    1986-10-01

    Specially formulated insulator materials with improved strength and high-voltage properties were developed and used for critical components of the flexible transmission lines to the TFTR neutral beam ion sources. These critical components are plates which support central conductors as they exit the high-voltage power supply and enter the ion source enclosure. Each plate acts both as a high-voltage insulator and as a pressure barrier to the SF 6 insulating gas. The original plate was made of commercial glass-epoxy laminate which limited the plate voltage capacity. The newly developed insulator is made of specially-formulated cycloalphatic Di-epoxide whose isotropic properties exhibit increased arc resistance. It is cast in one piece with skirts which greatly increase the breakdown voltage. This paper discusses the design, fabrication and testing of the new insulator

  13. Emissions from SF6 appliances in Norway. Additional report No. 2

    International Nuclear Information System (INIS)

    Gjarede, Anne Cathrine

    1999-01-01

    The report presents facts regarding the Norwegian SF 6 emissions and the significance for the Norwegian climatic gas accounts in order to evaluate whether 12-24 kV SF 6 appliances are environmentally acceptable. Estimations show that emissions from such equipment contribute with about 0.2 % of the total Norwegian CO 2 emissions in 1993. The SF 6 which is stored in electric appliances, may either be recycled or decomposed to more environmentally acceptable end products. The report concludes that the contribution to the greenhouse effects from SF 6 appliances is minimal

  14. Laser Spectroscopy on Ozone Destruction by SF6 Decomposed Products

    OpenAIRE

    北嶋, 巌; 村上, 和幸; 田中, 淳一; 岡井, 善四郎

    2002-01-01

    This paper reports on the identification of the SF6 decomposed products and the possibility of the ozone destruction by it. SF6 gas absorbs very strongly the 10.6μm P branch of C02 laser beam,so that the trace detection under ppb will be easily performed by the laser photo-acoustic method. We observed a new absorption spectra within the 9.6μm P branch resulted from the decomposed molecules after 2 hours 1 Hz-pulsed discharge of SF6 gas. As a resu1t ofthe gas chromatograph, it will be assumed ...

  15. Effect of the percentage of SF sub 6 (100%-10%-5%) on the decomposition of SF sub 6 -N sub 2 mixtures under negative dc coronas in the presence of water vapour or oxygen

    CERN Document Server

    Díaz, J; Casanovas, J

    2003-01-01

    Low SF sub 6 content SF sub 6 -N sub 2 mixtures have recently been proposed as a replacement for pure SF sub 6 in the insulation of gas insulated lines (GIL). Among the areas of investigation of such gas mixtures, their electrical decomposition under corona discharges must be studied considering the possible occurrence of such stress in GIL. This paper presents data concerning the decomposition of high-pressure SF sub 6 -N sub 2 (5 : 95) mixtures (400 kPa) submitted to negative dc coronas in the absence or presence of 0.3% H sub 2 O or 0.3% O sub 2. The chemical stability of these mixtures is compared with that of SF sub 6 -N sub 2 (10 : 90) mixtures or undiluted SF sub 6 investigated in the same conditions in a previous paper. The corona discharges were generated with a point-to-plane set-up and the gaseous by-products were assayed by gas chromatography at the end of each run carried out over a range of transported charge covering 0-13 C. The following by-products were detected and assayed: SOF sub 4 , SO su...

  16. Electric Field and Current Density Performance Analysis of Sf6, C4f8 and CO2 Gases As An Insulation

    Science.gov (United States)

    Mazli, Ahmad Danial Ahmad; Jamail, Nor Akmal Mohd; Azlin Othman, Nordiana

    2017-08-01

    SF6 gases are not only widely used as an insulating component in electric power industry but also as an arc extinguishing performance in high voltage (HV) gas-insulated circuit breaker (GCB). SF6 gases is generally used in the production of semiconductor materials and devices. Though these gasses is widely used in many application, the presences of temperature hotspot in the insulations may affect the insulation characteristics particularly electric field and current density. Therefore, it is important to determine the relationship between electric field and current density of gasses used in the insulator in the presence of hotspot. In this paper, three types of gases in particular Sulphur Hexafluoride (SF6), Octafluorocylobutane (C4F8), and Carbon Dioxide (CO2) was used in the insulator for gas insulation with the presence of two hotspots. These two hotspost were detected by referring the rising temperature in the insulator which are 1000 and 2000 Kelvin temperature for hotspot 1 and hotspot 2, respectively. From the simulation results, it can be concluded that Sulphur Hexafluoride (SF6) is the best choice for gas insulation since it had the lowest current density and electric field compared to Octafluorocylobutane (C4F8), and Carbon Dioxide (CO2). It is observed that the maximum current density and electric field for SF6 during normal condition are 358.94 × 103 V/m and 0.643 × 109 A/m2, respectively. Meanwhile, during temperature rising at hotspot 1 and hotspot 2, SF6 also had lowest current density and electric field compared to the other gasses where the results for Emax and Jmax at hotspot 1 are 322.34 × 103 V/m and 1.934 × 109 A/m2, respectively; While, Emax and Jmax at hotspot 2 are 259.77× 103 V/m and 2.824 × 109 A/m2. The results of this analysis can be used to find the best choices of gas that can be used in the insulator.

  17. Study on SF6 trace experiment in Lianyungang Nuclear Power Plant

    International Nuclear Information System (INIS)

    Hu Erbang; Yan Jiangyu; Zhang Yongyi; Wen Lianzhong

    2001-01-01

    10 times SF 6 trace experiments were successfully performed in August 1997 on a very complex terrain of Lianyungang Nuclear Power Plant in order to obtain plume trajectory and diffusion parameters. SF 6 is released from the top of a tower of 100 m. The sample points are arranged not only on the sample lines but also on the areas near residences. About 50 samples are obtained in each SF 6 trace experiment. The samples of SF 6 are analysed by the GC-ECD method. The weather stability is 5 times C and D stabilities respectively if using P-G method or 10 times D stabilities if using ΔT-U method. A least-square method is adopted to obtain the diffusion parameters from diffusion equation. Meanwhile the effect on the diffusion parameters from sampling time is measured based on the above SF 6 trace experiment

  18. Low energy electron attachment to SF6 in N2, Ar, and Xe buffer gases

    International Nuclear Information System (INIS)

    Hunter, S.R.; Carter, J.G.; Christophorou, L.G.

    1989-01-01

    The electron attachment rate constants k/sub a/ for SF 6 have been measured in dilute mixtures of SF 6 in high pressure (>1 atm) N 2 , Ar, and Xe buffer gases at room temperature (T≅300 K) over a wide E/N range (electric field strength to gas number density ratio), corresponding to mean electron energies from near thermal electron energies (≅0.04 eV) to ≅4.3 eV. Particular attention has been paid to the effects of space charge distortion, molecular impurities, and changes in the electron energy distribution function on the measured electron attachment rate constant values at the lower E/N values in these mixtures. The present measured thermal electron attachment rate constants in SF 6 /N 2 and SF 6 /Xe gas mixtures are in excellent agreement with recent accurate measurements of these parameters in several SF 6 /buffer gas mixtures. At higher values, the present SF 6 /N 2 measurements are in fair agreement with previous measurements, while no previous measurements using Ar and Xe buffer gases have been published. These measurements have been used in numerical two term, spherical harmonic Boltzmann equation analyses of the electron motion in these gas mixtures to obtain the low energy ( 6 . The present derived electron attachment cross sections are compared with recently measured and derived nondissociative and dissociative electron attachment cross sections for SF 6

  19. Experimental study on the influence of radiation on high-voltage insulation gases

    International Nuclear Information System (INIS)

    Fujiwara, Yukio; Inoue, Takashi; Miyamoto, Kenji; Miyamoto, Naoki; Ohara, Yoshihiro; Okumura, Yoshikazu; Watanabe, Kazuhiro

    1999-12-01

    In a neutral beam injection (NBI) system for next generation tokamaks such as International Thermonuclear Experimental Reactor (ITER), insulation gas around a beam source will be irradiated with neutrons and gamma rays from the reactor. It is necessary to evaluate the influence of the radiation on the insulation gas for the engineering design of the ITER-NBI system. In the present paper, the influence of the 60 Co gamma rays on air, SF 6 , C 2 F 6 , CO 2 , and mixing gas of air and SF 6 was studied. Ionization current and voltage-holding characteristics of the gases were measured for an absorbed dose rate of 0.45 Gy/s using parallel disk electrodes whose diameter is 130 mm. Saturation current proved to increase linearly with a gap length between the electrodes, gas pressure, an absorbed dose rate, and molecular weight of the gases. Voltage-holding capability was degraded by about 10 %; the degree of the degradation did not depend on the absorbed dose rate. Dissociative products of SF 6 by the irradiation were also analyzed with a quadrupole mass spectrometer. News peaks that did not exist before irradiation appeared at the m/e of 48, 64, 67, 83, 86, 102, and 105 after irradiation. The amount of the dissociative products turned out to be saturated at a higher absorbed dose. (author)

  20. Research on technology of online gas chromatograph for SF6 decomposition products

    Science.gov (United States)

    Li, L.; Fan, X. P.; Zhou, Y. Y.; Tang, N.; Zou, Z. L.; Liu, M. Z.; Huang, G. J.

    2017-12-01

    Sulfur hexafluoride (SF6) decomposition products were qualitatively and quantitatively analyzed by several gas chromatographs in the laboratory. Test conditions and methods were selected and optimized to minimize and eliminate the SF6’ influences on detection of other trace components. The effective separation and detection of selected characteristic gases were achieved. And by comparison among different types of gas chromatograph, it was found that GPTR-S101 can effectively separate and detect SF6 decomposition products and has best the best detection limit and sensitivity. On the basis of GPTR-S101, online gas chromatograph for SF6decomposition products (GPTR-S201) was developed. It lays the foundation for further online monitoring and diagnosis of SF6.

  1. Ground-based FTIR retrievals of SF6 on Reunion Island

    Directory of Open Access Journals (Sweden)

    M. Zhou

    2018-02-01

    Full Text Available SF6 total columns were successfully retrieved from FTIR (Fourier transform infrared measurements (Saint Denis and Maïdo on Reunion Island (21° S, 55° E between 2004 and 2016 using the SFIT4 algorithm: the retrieval strategy and the error budget were presented. The FTIR SF6 retrieval has independent information in only one individual layer, covering the whole of the troposphere and the lower stratosphere. The trend in SF6 was analysed based on the FTIR-retrieved dry-air column-averaged mole fractions (XSF6 on Reunion Island, the in situ measurements at America Samoa (SMO and the collocated satellite measurements (Michelson Interferometer for Passive Atmospheric Sounding, MIPAS, and Atmospheric Chemistry Experiment Fourier Transform Spectrometer, ACE-FTS in the southern tropics. The SF6 annual growth rate from FTIR retrievals is 0.265 ± 0.013 pptv year−1 for 2004–2016, which is slightly weaker than that from the SMO in situ measurements (0.285 ± 0.002 pptv year−1 for the same time period. The SF6 trend in the troposphere from MIPAS and ACE-FTS observations is also close to the ones from the FTIR retrievals and the SMO in situ measurements.

  2. Ground-based FTIR retrievals of SF6 on Reunion Island

    Science.gov (United States)

    Zhou, Minqiang; Langerock, Bavo; Vigouroux, Corinne; Wang, Pucai; Hermans, Christian; Stiller, Gabriele; Walker, Kaley A.; Dutton, Geoff; Mahieu, Emmanuel; De Mazière, Martine

    2018-02-01

    SF6 total columns were successfully retrieved from FTIR (Fourier transform infrared) measurements (Saint Denis and Maïdo) on Reunion Island (21° S, 55° E) between 2004 and 2016 using the SFIT4 algorithm: the retrieval strategy and the error budget were presented. The FTIR SF6 retrieval has independent information in only one individual layer, covering the whole of the troposphere and the lower stratosphere. The trend in SF6 was analysed based on the FTIR-retrieved dry-air column-averaged mole fractions (XSF6) on Reunion Island, the in situ measurements at America Samoa (SMO) and the collocated satellite measurements (Michelson Interferometer for Passive Atmospheric Sounding, MIPAS, and Atmospheric Chemistry Experiment Fourier Transform Spectrometer, ACE-FTS) in the southern tropics. The SF6 annual growth rate from FTIR retrievals is 0.265 ± 0.013 pptv year-1 for 2004-2016, which is slightly weaker than that from the SMO in situ measurements (0.285 ± 0.002 pptv year-1) for the same time period. The SF6 trend in the troposphere from MIPAS and ACE-FTS observations is also close to the ones from the FTIR retrievals and the SMO in situ measurements.

  3. Efficient removal of sulfur hexafluoride (SF6) through reacting with recycled electroplating sludge.

    Science.gov (United States)

    Zhang, Jia; Zhou, Ji Zhi; Liu, Qiang; Qian, Guangren; Xu, Zhi Ping

    2013-06-18

    This paper reports that recycled electroplating sludge is able to efficiently remove greenhouse gas sulfur hexafluoride (SF6). The removal process involves various reactions of SF6 with the recycled sludge. Remarkably, the sludge completely removed SF6 at a capacity of 1.10 mmol/g (SF6/sludge) at 600 °C. More importantly, the evolved gases were SO2, SiF4, and a limited amount of HF, with no toxic SOF4, SO2F2, or SF4 being detected. These generated gases can be readily captured and removed by NaOH solution. The reacted solids were further found to be various metal fluorides, thus revealing that SF6 removal takes place by reacting with various metal oxides and silicate in the sludge. Moreover, the kinetic investigation revealed that the SF6 reaction with the sludge is a first-order chemically controlled process. This research thus demonstrates that the waste electroplating sludge can be potentially used as an effective removal agent for one of the notorious greenhouse gases, SF6.

  4. A microcontroller application as X-ray machine's high voltage controller

    International Nuclear Information System (INIS)

    Wiranto Budi Santoso; Beny Syawaludin

    2010-01-01

    A micro controller application as x-ray machine's high voltage controller has been carried out. The purpose of this micro controller application is to give an accurate high voltage supply to the x-ray tube so that the x-ray machine could produce the result as expected. The micro controller based X-ray machine's high voltage controller receives an input voltage from the keypad. This input value is displayed in the LCD (Liquid Crystal Display) screen. Then micro controller uses this input data to drive a stepper motor. The stepper motor adjusts the high voltage auto transformer's output according to the input value. The micro controller is programmed using BASCOM-8051 compiler. The test results show that the stepper motor could rotate according to an input value (author)

  5. Validation of the SF-6D Health State Utilities Measure in Lower Extremity Sarcoma

    Directory of Open Access Journals (Sweden)

    Kenneth R. Gundle

    2014-01-01

    Full Text Available Aim. Health state utilities measures are preference-weighted patient-reported outcome (PRO instruments that facilitate comparative effectiveness research. One such measure, the SF-6D, is generated from the Short Form 36 (SF-36. This report describes a psychometric evaluation of the SF-6D in a cross-sectional population of lower extremity sarcoma patients. Methods. Patients with lower extremity sarcoma from a prospective database who had completed the SF-36 and Toronto Extremity Salvage Score (TESS were eligible for inclusion. Computed SF-6D health states were given preference weights based on a prior valuation. The primary outcome was correlation between the SF-6D and TESS. Results. In 63 pairs of surveys in a lower extremity sarcoma population, the mean preference-weighted SF-6D score was 0.59 (95% CI 0.4–0.81. The distribution of SF-6D scores approximated a normal curve (skewness = 0.11. There was a positive correlation between the SF-6D and TESS (r=0.75, P<0.01. Respondents who reported walking aid use had lower SF-6D scores (0.53 versus 0.61, P=0.03. Five respondents underwent amputation, with lower SF-6D scores that approached significance (0.48 versus 0.6, P=0.06. Conclusions. The SF-6D health state utilities measure demonstrated convergent validity without evidence of ceiling or floor effects. The SF-6D is a health state utilities measure suitable for further research in sarcoma patients.

  6. Breakdown characteristics of SF6/N2 in severely non-uniform electric fields at low temperatures

    Science.gov (United States)

    Wang, Y.; Gao, Z. W.; Li, G. X.; Zhu, X. C.; Yu, C. L.; Liang, J. Q.; Li, L.

    2018-01-01

    SF6 has good electrical insulating properties, which is widely used as an insulating medium of GIS, GIL and other electrical equipment. However, the reliability of electrical equipments´ insulated gas is greatly challenged in cold areas, since SF6 more readily liquefies. To solve the problem, SF6 can be mixed with N2 to maintain the insulating properties, and reduce its liquefaction temperature. Such practice has certain application prospect. In this paper, a breakdown experimental platform was built to study the insulating property of SF6/N2 at low temperature, wherein the temperature of the platform can be adjusted. A severely non-uniform electric field was generated by a rod-plate electrode. The breakdown characteristics of SF6/N2 with different mixing proportions at low pressures and low temperatures were measured. The result showed that the mixed gas was not liquefied within the temperature range. Temperature had insignificant influence on the insulating property thereof. The result in the paper has certain guiding significance for applying SF6/N2 mixed gas in high latitude areas.

  7. A Four-Phase High Voltage Conversion Ratio Bidirectional DC-DC Converter for Battery Applications

    Directory of Open Access Journals (Sweden)

    Li-Kun Xue

    2015-06-01

    Full Text Available This study presents a four-phase interleaved high voltage conversion ratio bidirectional DC-DC converter circuit based on coupled inductors and switched capacitors, which can eliminate the defects of conventional high voltage conversion ratio bidirectional DC-DC converters in terms of high-voltage/current stress, less efficiency and low-power limitation. Parallel channels are used to reduce current stress at the low-voltage side and series connected switched capacitors are used to enlarge voltage conversion ratio, reduce voltage stress and achieve auto current sharing. This paper proposes the operation principle, feature analysis and optimization design considerations. On this basis the objectives of high voltage conversion ratio, low voltage/current stress, high power density, high efficiency and high-power applications can be achieved. Some experimental results based on a 500 W prototype converter (24 V to 48 V at low-voltage side, 400 V at high-voltage side are given to verify the theoretical analysis and the effectiveness of the proposed converter.

  8. Unchained Melody: Revisiting the Estimation of SF-6D Values

    Science.gov (United States)

    Craig, Benjamin M.

    2015-01-01

    Purpose In the original SF-6D valuation study, the analytical design inherited conventions that detrimentally affected its ability to predict values on a quality-adjusted life year (QALY) scale. Our objective is to estimate UK values for SF-6D states using the original data and multi-attribute utility (MAU) regression after addressing its limitations and to compare the revised SF-6D and EQ-5D value predictions. Methods Using the unaltered data (611 respondents, 3503 SG responses), the parameters of the original MAU model were re-estimated under 3 alternative error specifications, known as the instant, episodic, and angular random utility models. Value predictions on a QALY scale were compared to EQ-5D3L predictions using the 1996 Health Survey for England. Results Contrary to the original results, the revised SF-6D value predictions range below 0 QALYs (i.e., worse than death) and agree largely with EQ-5D predictions after adjusting for scale. Although a QALY is defined as a year in optimal health, the SF-6D sets a higher standard for optimal health than the EQ-5D-3L; therefore, it has larger units on a QALY scale by construction (20.9% more). Conclusions Much of the debate in health valuation has focused on differences between preference elicitation tasks, sampling, and instruments. After correcting errant econometric practices and adjusting for differences in QALY scale between the EQ-5D and SF-6D values, the revised predictions demonstrate convergent validity, making them more suitable for UK economic evaluations compared to original estimates. PMID:26359242

  9. 250 kV 6 mA compact Cockcroft-Walton high-voltage power supply

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Zhan-Wen; Su, Xiao-Dong; Wei, Zhen; Huang, Zhi-Wu; Miao, Tian-You; Su, Tong-Ling [School of Nuclear Science and Technology, Lanzhou University, Lanzhou 730000 (China); Lu, Xiao-Long; Wang, Jun-Run; Yao, Ze-En, E-mail: zeyao@lzu.edu.cn [School of Nuclear Science and Technology, Lanzhou University, Lanzhou 730000 (China); Engineering Research Center for Neutron Application, Ministry of Education, Lanzhou University, Lanzhou 730000 (China)

    2016-08-15

    A compact power supply system for a compact neutron generator has been developed. A 4-stage symmetrical Cockcroft-Walton circuit is adopted to produce 250 kV direct current high-voltage. A 2-stage 280 kV isolation transformer system is used to drive the ion source power supply. For a compact structure, safety, and reliability during the operation, the Cockcroft-Walton circuit and the isolation transformer system are enclosed in an epoxy vessel containing the transformer oil whose size is about ∅350 mm × 766 mm. Test results indicate that the maximum output voltage of the power supply is 282 kV, and the stability of the output voltage is better than 0.63% when the high voltage power supply is operated at 250 kV, 6.9 mA with the input voltage varying ±10%.

  10. Angular dependence of etch rates in the etching of poly-Si and fluorocarbon polymer using SF6, C4F8, and O2 plasmas

    International Nuclear Information System (INIS)

    Min, Jae-Ho; Lee, Gyeo-Re; Lee, Jin-Kwan; Moon, Sang Heup; Kim, Chang-Koo

    2004-01-01

    The dependences of etch rates on the angle of ions incident on the substrate surface in four plasma/substrate systems that constitute the advanced Bosch process were investigated using a Faraday cage designed for the accurate control of the ion-incident angle. The four systems, established by combining discharge gases and substrates, were a SF 6 /poly-Si, a SF 6 /fluorocarbon polymer, an O 2 /fluorocarbon polymer, and a C 4 F 8 /Si. In the case of SF 6 /poly-Si, the normalized etch rates (NERs), defined as the etch rates normalized by the rate on the horizontal surface, were higher at all angles than values predicted from the cosine of the ion-incident angle. This characteristic curve shape was independent of changes in process variables including the source power and bias voltage. Contrary to the earlier case, the NERs for the O 2 /polymer decreased and eventually reached much lower values than the cosine values at angles between 30 deg. and 70 deg. when the source power was increased and the bias voltage was decreased. On the other hand, the NERs for the SF 6 /polymer showed a weak dependence on the process variables. In the case of C 4 F 8 /Si, which is used in the Bosch process for depositing a fluorocarbon layer on the substrate surface, the deposition rate varied with the ion incident angle, showing an S-shaped curve. These characteristic deposition rate curves, which were highly dependent on the process conditions, could be divided into four distinct regions: a Si sputtering region, an ion-suppressed polymer deposition region, an ion-enhanced polymer deposition region, and an ion-free polymer deposition region. Based on the earlier characteristic angular dependences of the etch (or deposition) rates in the individual systems, ideal process conditions for obtaining an anisotropic etch profile in the advanced Bosch process are proposed

  11. Fabrication of SiC nanopillars by inductively coupled SF6/O2 plasma etching

    International Nuclear Information System (INIS)

    Choi, J H; Bano, E; Latu-Romain, L; Dhalluin, F; Chevolleau, T; Baron, T

    2012-01-01

    In this paper, we demonstrate a top-down fabrication technique for nanometre scale silicon carbide (SiC) pillars using inductively coupled plasma etching. A set of experiments in SF 6 -based plasma was carried out in order to realize high aspect ratio SiC nanopillars. The etched SiC nanopillars using a small circular mask pattern (115 nm diameter) show high aspect ratio (7.4) with a height of 2.2 µm at an optimum bias voltage (300 V) and pressure (6 mTorr). Under the optimal etching conditions using a large circular mask pattern with 370 nm diameter, the obtained SiC nanopillars exhibit high anisotropy features (6.4) with a large etch depth (>7 µm). The etch characteristic of the SiC nanopillars under these conditions shows a high etch rate (550 nm min -1 ) and a high selectivity (over 60 for Ni). We also studied the etch profile of the SiC nanopillars and mask evolution over the etching time. As the mask pattern size shrinks in nanoscale, vertical and lateral mask erosion plays a crucial role in the etch profile of the SiC nanopillars. Long etching process makes the pillars appear with a hexagonal shape, coming from the crystallographic structure of α-SiC. It is found that the feature of pillars depends not only on the etching process parameters, but also on the crystallographic structure of the SiC phase. (paper)

  12. A Study of Parameters Related to the Etch Rate for a Dry Etch Process Using NF3/O2 and SF6/O2

    Directory of Open Access Journals (Sweden)

    Seon-Geun Oh

    2014-01-01

    Full Text Available The characteristics of the dry etching of SiNx:H thin films for display devices using SF6/O2 and NF3/O2 were investigated using a dual-frequency capacitively coupled plasma reactive ion etching (CCP-RIE system. The investigation was carried out by varying the RF power ratio (13.56 MHz/2 MHz, pressure, and gas flow ratio. For the SiNx:H film, the etch rates obtained using NF3/O2 were higher than those obtained using SF6/O2 under various process conditions. The relationships between the etch rates and the usual monitoring parameters—the optical emission spectroscopy (OES intensity of atomic fluorine (685.1 nm and 702.89 nm and the voltages VH and VL—were investigated. The OES intensity data indicated a correlation between the bulk plasma density and the atomic fluorine density. The etch rate was proportional to the product of the OES intensity of atomic fluorine (I(F and the square root of the voltages (Vh+Vl on the assumption that the velocity of the reactive fluorine was proportional to the square root of the voltages.

  13. Lens subluxation after plasmin and SF6 injections in rabbit eyes.

    Directory of Open Access Journals (Sweden)

    Wei-Chi Wu

    Full Text Available To investigate the rate of lens subluxation following plasmin and/or SF6 injections in eyes, and whether a subsequent elevated level of vascular endothelial growth factor (VEGF and vitreous tap would aggravate subluxation.Four groups of rabbits were used. Group 1 received an intravitreal injection (IVI of plasmin and SF6 in the right eye; group 2 received an IVI of plasmin in the right eye; group 3 received an IVI of SF6 in the right eye; and group 4 received an IVI of balanced salt solution in the right eye. After treatment, IVIs of VEGF were given and vitreous tap was performed three times, followed by clinical observation of lens subluxation and scanning electronic microscope evaluation of the zonular fibers.After IVIs of plasmin and SF6, and VEGF and vitreous tap had been performed one to three times, lens subluxation was noted in 0%, 43%, 71%, 71%, and 86% of the eyes in group 1. After IVIs of plasmin, VEGF, and vitreous tap had been performed one to three times, lens subluxation was noted in 11%, 22%, 44%, 44%, and 67% of the eyes in group 2. The eyes in group 3 and 4 did not show signs of lens subluxation after VEGF IVIs and vitreous tap. Histology confirmed zonular fiber damage in the eyes treated with plasmin.The incidence of lens subluxation increased following plasmin injections in the eyes, and this was aggravated by the subsequent high VEGF level in the eyes and vitreous tapping. Zonular fibers were disrupted following plasmin treatment. These effects should be kept in mind when using plasmin enzymes in patients with vitreoretinal abnormalities.

  14. Interlaboratory comparison of SF6-determinations used within the framework of tracer releases

    International Nuclear Information System (INIS)

    Vanderborght, B.

    1985-01-01

    An international intercomparison exercise, for determination of trace amounts of SF 6 in air was set up, to make interchange of experimental results or common tracer experiments possible between European laboratories. SCK, Belgium made 6 SF 6 samples in the 10 ppt to 10 ppb range. Samples were analyzed by CEN (F), CERL (UK), JRC (I), KEMA (NL), LHW (NL), NILU (N), APL (DK), WDB (FRG) and SCK (B). Very good agreement was obtained between SCK, CERL, APL and NILU. LHW and KEMA obtained systematically lower results than those four laboratories; the problem might originate in manufacturing of mother samples under high pressure. CEN and WDB work in a higher concentration range and their analysis of trace amounts is less accurate. JRC samples were contaminated and accuracy of their analysis cannot be evaluated. SF 6 samples in PVC plastic bags are not stable enough over long periods, especially with ambient temperature higher than 30 0 C. Transport of samples in plastic bags over long distances is not advisable when transport conditions cannot be well controlled

  15. Time-resolved output spectrum from a hydrogen fluoride laser using mixtures of SF6 and HI

    International Nuclear Information System (INIS)

    Greiner, N.R.

    1975-01-01

    The time-resolved spectrum from a transverse-discharge hydrogen fluoride (HF) laser using a mixture of SF 6 and HI is reported. Because this spectrum matches that from a high-pressure H 2 -F 2 laser, and because the SF 6 -HI mixture is chemically stable, this laser should be a suitable and convenient source for probing H 2 -F 2 amplifiers

  16. Dual-harmonic auto voltage control for the rapid cycling synchrotron of the Japan Proton Accelerator Research Complex

    Directory of Open Access Journals (Sweden)

    Fumihiko Tamura

    2008-07-01

    Full Text Available The dual-harmonic operation, in which the accelerating cavities are driven by the superposition of the fundamental and the second harmonic rf voltage, is useful for acceleration of the ultrahigh intensity proton beam in the rapid cycling synchrotron (RCS of Japan Proton Accelerator Research Complex (J-PARC. However, the precise and fast voltage control of the harmonics is necessary to realize the dual-harmonic acceleration. We developed the dual-harmonic auto voltage control system for the J-PARC RCS. We describe details of the design and the implementation. Various tests of the system are performed with the RCS rf system. Also, a preliminary beam test has been done. We report the test results.

  17. Construct validity of SF-6D health state utility values in an employed population.

    Science.gov (United States)

    Baxter, Siyan; Sanderson, Kristy; Venn, Alison; Otahal, Petr; Palmer, Andrew J

    2015-04-01

    Health utility values permit cost utility analysis in workplace health promotion; however, utility measures of working populations have not been validated. To investigate construct validity of SF-6D health utility in a public service workforce. SF-12v2 Health Survey was administered to 3,408 randomly selected public service employees in Australia in 2010. SF-12 scores were converted to SF-6D health utility values. Associations and correlates of SF-6D with health, socio-demographic and work characteristics [comorbidities, body mass index (BMI), Kessler-10 psychological distress (K10), education, salary, effort-reward imbalance (ERI), absenteeism] were explored. Ceiling effects were analysed. Nationally representative employee SF-6D values from the Household, Income and Labour Dynamics in Australia (HILDA) survey (n = 11,234) were compared. All analyses were stratified by sex. Mean (SE) age was 45.7 (0.35) males; 44.5 (0.22) females. Females represented 72 % of the sample. Mean (SE) health utility 0.792 (0.004); 0.771 (0.003) was higher in males. SF-6D demonstrated both a significant inverse association (p negative correlations (female; male) with K10 (r = -0.63; r = -0.66), comorbidity count (r = -0.40; r = -0.33), ERI (r = -0.37; r = -0.34) and absenteeism (p imbalance and absenteeism are negatively associated with employee health. SF-6D is a valid measure of perceived health states in working populations.

  18. SF6 laser remote sensing by CO2 laser DIAL lidar

    International Nuclear Information System (INIS)

    Parvin, P.; Basam, Z.; Zamanipour, Z.; Kariminezhad, H.; Boyook, N.; Borna, F.; Azari, T.; Eshragi, N.; Ataran, A.; Ghods Ahmad Zadeh, R.

    2004-01-01

    A DIAL system using tunable CO 2 laser has been demonstrated practically for remote sensing of SF 6 components in Mashad Shahid Motahhari Research Complex. Non toxic components of SF 6 as a rare isotope is studied to calibrate the lidar function in several conditions. The whole system enables us to detect ppm amounts of chemical gases as well as pollutants and poisonous species

  19. The project of autocontrol for CAEN high voltage systems in high energy physics experiments

    International Nuclear Information System (INIS)

    Qian Sen; Wang Zhimin; Chinese Academy of Sciences, Beijing; Cai Xiao; Wang Yifang; Zhang Jiawen; Yang Changgen

    2008-01-01

    Based on TCP/IP network communication techniques, CAMAC Bus Technology, PCI Bus Technology and RS232 Serial Communication Technique, we developed and established a serial of software in Linux or Win32 system to auto control these high voltage systems made by CAEN Company, which are always used in high energy physics experiments. The operator can use this software to control and monitor the system independently, or encapsulate it into the DAQ system to control the test system and acquire data synchronously and high-efficaciously. (authors)

  20. In Situ Measurements of Sulfur Hexafluoride (SF6) and age of air from NH sources during the Atmospheric Tomography (ATom) global airborne survey

    Science.gov (United States)

    Elkins, J. W.; Moore, F. L.; Hintsa, E. J.; Ray, E. A.; Dutton, G. S.; Nance, J. D.; Hall, B. D.; Dlugokencky, E. J.; Sweeney, C.; Montzka, S. A.; Newman, P. A.

    2017-12-01

    Atmospheric SF6 is an excellent tracer of atmospheric transport in the troposphere, because of its long lifetime (850 years), mostly northern hemispheric (NH) emissions (95%), and high atmospheric growth rate ( 4%/yr.). The gas is used in the distribution of electrical power, because it is an excellent insulator. It is primarily released through its use (leaking and refilling) in high voltage power transformers. Two NOAA/GMD airborne, in situ gas chromatographs (GCs), PAN and other Trace Hydrohalocarbons ExpeRiment (PANTHER) and UAS Chromatograph for Atmospheric Trace Species (UCATS), operated on the first two circuits of the Atmospheric Tomography Mission (ATom-1 & ATom-2). Both instruments measure nitrous oxide (N2O) and sulfur hexafluoride (SF6) once every 70 seconds using a very sensitive electron capture detector (ECD). We combined both measurements into one data set for analysis of twice the amount of data, since both instruments are comparable and used the same gas standards. The main purpose of ATom is to study the influence of air quality on climate during the four seasons, where two seasons are completed so far. The altitude-latitude cross sections of SF6 mixing ratios during the ATom-1 (left) shows sources are mostly located in the NH ( 95%). The upper troposphere shows inter-hemispheric mixing. The polar stratosphere shows older air that is mixed with air from the mesospheric sink. Using the procedure described by Waugh et al., (2013) [JGR-Atmos. 10.1002/jgrd.50189] and a recent growth rate of 0.32 ppt yr-1, we have calculated the mean age of each SF6 measurement from its source at ground level in the NH (lat. range of 30-50°N). The contours of age (right) are in agreement with the mean inter-hemispheric exchange time (τNS) of 1.2 yr and higher ages in the polar stratosphere (2.5-3.0 yr).

  1. TM6SF2 and MAC30, new enzyme homologues in sterol metabolism and common metabolic disease.

    Directory of Open Access Journals (Sweden)

    Luis eSanchez-Pulido

    2014-12-01

    Full Text Available Carriers of the Glu167Lys coding variant in the TM6SF2 gene have recently been identified as being more susceptible to non-alcoholic fatty liver disease (NAFLD, yet exhibit lower levels of circulating lipids and hence are protected against cardiovascular disease. Despite the physiological importance of these observations, the molecular function of TM6SF2 remains unknown, and no sequence similarity with functionally characterised proteins has been identified. In order to trace its evolutionary history and to identify functional domains, we embarked on a computational protein sequence analysis of TM6SF2. We identified a new domain, the EXPERA domain, which is conserved among TM6SF, MAC30/TMEM97 and EBP (D8,D7 sterol isomerase protein families. EBP mutations are the cause of chondrodysplasia punctata 2 X-linked dominant (CDPX2, also known as Conradi-Hünermann-Happle syndrome, a defective cholesterol biosynthesis disorder. Our analysis of evolutionary conservation among EXPERA domain-containing families and the previously suggested catalytic mechanism for the EBP enzyme, indicate that TM6SF and MAC30/TMEM97 families are both highly likely to possess, as for the EBP family, catalytic activity as sterol isomerases. This unexpected prediction of enzymatic functions for TM6SF and MAC30/TMEM97 is important because it now permits detailed experiments to investigate the function of these key proteins in various human pathologies, from cardiovascular disease to cancer.

  2. Spot auto-focusing and spot auto-stigmation methods with high-definition auto-correlation function in high-resolution TEM.

    Science.gov (United States)

    Isakozawa, Shigeto; Fuse, Taishi; Amano, Junpei; Baba, Norio

    2018-04-01

    As alternatives to the diffractogram-based method in high-resolution transmission electron microscopy, a spot auto-focusing (AF) method and a spot auto-stigmation (AS) method are presented with a unique high-definition auto-correlation function (HD-ACF). The HD-ACF clearly resolves the ACF central peak region in small amorphous-thin-film images, reflecting the phase contrast transfer function. At a 300-k magnification for a 120-kV transmission electron microscope, the smallest areas used are 64 × 64 pixels (~3 nm2) for the AF and 256 × 256 pixels for the AS. A useful advantage of these methods is that the AF function has an allowable accuracy even for a low s/n (~1.0) image. A reference database on the defocus dependency of the HD-ACF by the pre-acquisition of through-focus amorphous-thin-film images must be prepared to use these methods. This can be very beneficial because the specimens are not limited to approximations of weak phase objects but can be extended to objects outside such approximations.

  3. Power-MOSFET Voltage Regulator

    Science.gov (United States)

    Miller, W. N.; Gray, O. E.

    1982-01-01

    Ninety-six parallel MOSFET devices with two-stage feedback circuit form a high-current dc voltage regulator that also acts as fully-on solid-state switch when fuel-cell out-put falls below regulated voltage. Ripple voltage is less than 20 mV, transient recovery time is less than 50 ms. Parallel MOSFET's act as high-current dc regulator and switch. Regulator can be used wherever large direct currents must be controlled. Can be applied to inverters, industrial furnaces photovoltaic solar generators, dc motors, and electric autos.

  4. Mechanism for negative corona current pulse in CO sub 2 -SF sub 6 mixtures

    CERN Document Server

    Zahoranova, A; Simor, M; Cernak, M

    2003-01-01

    Current waveforms of first negative corona pulses have been measured in CO sub 2 -SF sub 6 mixtures over a pressure range extending from 6.65 to 50 kPa and various overvoltages. Effects of changing cathode secondary electron emission were studied using a copper cathode coated by CuI and graphite. For a given set of experimental conditions it is concluded that in the mixtures containing up to 30% of SF sub 6 the negative corona pulse is associated with the formation of a cathode-directed streamer-like ionizing wave in the immediate vicinity of the cathode. This is in contrast to the discharge behaviour in air-SF sub 6 and N sub 2 -SF sub 6 mixtures, where in similar conditions the discharge develops according to a multi-avalanche Townsend mechanism. (rapid communication)

  5. Innovation of High Voltage Supply Adjustment Device on Diagnostic X-Ray Machine

    International Nuclear Information System (INIS)

    Sujatno; Wiranto Budi Santoso

    2010-01-01

    Innovation of high voltage supply adjustment device on diagnostic x-ray machine has been carried out. The innovation is conducted by utilizing an electronic circuit as a high voltage adjustment device. Usually a diagnostic x-ray machine utilizes a transformer or an auto-transformer as a high voltage supply adjustment device. A high power diagnostic x-ray machine needs a high power transformer which has big physical dimension. Therefore a box control where the transformer is located has to have big physical dimension. Besides, the price of the transformer is expensive and hardly found in local markets. In this innovation, the transformer is replaced by an electronic circuit. The main component of the electronic circuit is Triac BTA-40. As adjustment device, the triac is controlled by a variable resistor which is coupled by a stepper motor. A step movement of stepper motor varies a value of resistor. The resistor value determines the triac gate voltage. Furthermore the triac will open according to the value of electrical current flowing to the gate. When the gate is open, electrical voltage and current will flow from cathode to anode of the triac. The value of these electrical voltage and current depend on gate open condition. Then this triac output voltage is feed to diagnostic x-ray machine high voltage supply. Therefore the high voltage value of diagnostic x-ray machine is adjusted by the output voltage of the electronic circuit. By using this electronic circuit, the physical dimension of diagnostic x-ray machine box control and the price of the equipment can be reduced. (author)

  6. Electron drift velocity in SF{sub 6} in strong electric fields determined from rf breakdown curves

    Energy Technology Data Exchange (ETDEWEB)

    Lisovskiy, V; Yegorenkov, V [Department of Physics and Technology, Kharkov National University, Svobody sq.4, Kharkov 61077 (Ukraine); Booth, J-P [Laboratoire de Physique des Plasmas, Ecole Polytechnique, Palaiseau 91128 (France); Landry, K [Unaxis Displays Division France SAS, 5, Rue Leon Blum, Palaiseau 91120 (France); Douai, D [Physical Sciences Division, Institute for Magnetic Fusion Research, CEA Centre de Cadarache, F-13108 Saint Paul lez Durance Cedex (France); Cassagne, V, E-mail: lisovskiy@yahoo.co [Developpement Photovoltaique Couches Minces, Total, 2, place Jean Millier, La Defense 6, 92400 Courbevoie (France)

    2010-09-29

    This paper presents measurements of the electron drift velocity V{sub dr} in SF{sub 6} gas for high reduced electric fields (E/N = 330-5655 Td (1 Td = 10{sup -17} V cm{sup 2})). The drift velocities were obtained using the method of Lisovskiy and Yegorenkov (1998 J. Phys. D: Appl. Phys. 31 3349) based on the determination of the pressure and voltage of the turning points of rf capacitive discharge breakdown curves for a range of electrode spacings. The V{sub dr} values thus obtained were in good agreement with those calculated from the cross-sections of Phelps and Van Brunt (1988 J. Appl. Phys. 64 4269) using the BOLSIG code. The validity of the Lisovskiy-Yegorenkov method is discussed and we show that it is applicable over the entire E/N range where rf discharge ignition at breakdown occurs for rf frequencies of 13.56 MHz or above.

  7. Arc modelling in SF6 circuit breakers

    International Nuclear Information System (INIS)

    Verite, J.C.; Boucher, T.; Comte, A.; Delalondre, C.; Robin-Jouan, P.; Serres, E.; Texier, V.; Barrault, M.; Chevrier, P.; Fievet, C.

    1995-06-01

    The paper presents the work done by an operator, EDF and two manufacturers to improve the physical models and numerical methods used to simulate the behavior of the plasma and cold gas around it in a breaking chamber of the HV SF6 circuit breaker, during the high-current phase. This work concerns flow phenomena, in particular incorporating compressibility and the study of turbulence, the coupling between these flow phenomena and electromagnetic phenomena, and finally, radiation - which plays an essential role in energy transfer during the high-current phase. For this latter aspect, emission but also absorption were proven to play a major role, and the two were introduced into the models. The paper presents the models developed and the results obtained with them for simulation of two circuit breaker mock-ups (a double-pressure circuit breaker mock-up and a self-expanding and rotating arc circuit breaker mock-up). (author)

  8. Effect of duration of the pause single-phase auto-reclosing on electro-power transmission capacitance

    Directory of Open Access Journals (Sweden)

    Krasil'nikova Tatyana

    2017-01-01

    Full Text Available This paper discusses the problem associated with accidents in the aerial line (AL ultra-high voltage (UHV due to its big length. In lines with a voltage of 500-1150 kV the overwhelming proportion of trips (98% is caused by single-phase short circuit (SPSC. A substantial portion (70% single-phase short circuits is erratic arc accidents which can be successfully eliminated in a high-speed auto-reclosing (HSAR or single-phase auto-reclosing (SPAR. Success single-phase auto-reclosing (SPAR at liquidation by single-phase short circuit (SPSC, on the one hand, is determined by the characteristics of the secondary arc current, and on the other hand the effectiveness of ways to reduce secondary arc current and recovery voltage development. The minimum dead time, at a HSAR it is usually taken as 0.5 s., at single-phase autoreclosing (SPAR it depends on the current value of the arc support is in the range of 0.5-3.0 s. The article shows high efficiency of use single-phase auto reclosing (SPAR at liquidation SPSC in a single-chain AL voltage of 500 kV, the dependence of the bandwidth of transmission in maintaining the dynamic stability from the length of the pause SPAR.

  9. Effects of SF6 plasma treatment on the properties of InGaZnO thin films

    Science.gov (United States)

    Choi, Jinsung; Bae, Byung Seong; Yun, Eui-Jung

    2018-03-01

    The effects of sulfur hexafluoride (SF6) plasma on the properties of amorphous InGaZnO (a-IGZO) thin films were examined. The properties of the a-IGZO thin films were characterized by Hall effect measurement, dynamic secondary ion mass spectroscopy (SIMS), and X-ray photoelectron spectroscopy (XPS). The IGZO thin films treated with SF6 plasma before annealing had a very high resistance mainly owing to the inclusion of S into the film surface, as evidenced by SIMS profiles. On the other hand, the samples treated with SF6 plasma after annealing showed better electrical properties with a Hall mobility of 10 cm2/(V·s) than the untreated samples or the samples SF6 plasma-treated before annealing. This was attributed to the increase in the number of oxygen vacancy defects in the a-IGZO thin films owing to the enhanced out-diffusion of O to the ambient and the increase in the number of F-related donor defects originating from the incorporation of a much larger amount of F than of S into the film surface, which were confirmed by XPS and SIMS.

  10. Mechanical strength and hydrophobicity of cotton fabric after SF6 plasma treatment

    International Nuclear Information System (INIS)

    Kamlangkla, K.; Paosawatyanyong, B.; Pavarajarn, V.; Hodak, Jose H.; Hodak, Satreerat K.

    2010-01-01

    Surface treatments to tailor fabric properties are in high demand by the modern garment industry. We studied the effect of radio-frequency inductively coupled SF 6 plasma on the surface characteristics of cotton fabric. The duration of the treatment and the SF 6 pressure were varied systematically. We measured the hydrophobicity of treated cotton as a function of storage time and washing cycles. We used the weight loss (%) along with the etching rate, the tensile strength, the morphology changes and the hydrophobicity of the fabric as observables after treatments with different plasma conditions. The weight loss remains below 1% but it significantly increases when the treatment time is longer than 5 min. Substantial changes in the surface morphology of the fiber are concomitant with the increased etching rate and increased weight loss with measurable consequences in their mechanical characteristics. The measured water absorption time reaches the maximum of 210 min when the SF 6 pressure is higher than 0.3 Torr. The water contact angle (149 deg.) and the absorption time (210 min) of cotton treated with extreme conditions appear to be durable as long as the fabric is not washed. X-ray photoelectron spectroscopy analysis reveals that the water absorption time of the fabric follows the same increasing trend as the fluorine/carbon ratio at the fabric surface and atom density of fluorine measured by Ar actinometer.

  11. Wideband Electrostatic Vibration Energy Harvester (e-VEH) Having a Low Start-Up Voltage Employing a High-Voltage Integrated Interface

    International Nuclear Information System (INIS)

    Dudka, A; Galayko, D; Basset, P; Cottone, F; Blokhina, E

    2013-01-01

    This paper reports on an electrostatic Vibration Energy Harvester (e-VEH) system, for which the energy conversion process is initiated with a low bias voltage and is compatible with wideband stochastic external vibrations. The system employs the auto-synchronous conditioning circuit topology with the use of a novel dedicated integrated low-power high-voltage switch that is needed to connect the charge pump and flyback – two main parts of the used conditioning circuit. The proposed switch is designed and implemented in AMS035HV CMOS technology. Thanks to the proposed switch device, which is driven with a low-voltage ground-referenced logic, the e-VEH system may operate within a large voltage range, from a pre-charge low voltage up to several tens volts. With such a high-voltage e-VEH operation, it is possible to obtain a strong mechanical coupling and a high rate of vibration energy conversion. The used transducer/resonator device is fabricated with a batch-processed MEMS technology. When excited with stochastic vibrations having an acceleration level of 0.8 g rms distributed in the band 110–170 Hz, up to 0.75 μW of net electrical power has been harvested with our system. This work presents an important milestone in the challenge of designing a fully integrated smart conditioning interface for the capacitive e-VEHs

  12. Multi-Port High Voltage Gain Modular Power Converter for Offshore Wind Farms

    Directory of Open Access Journals (Sweden)

    Sen Song

    2018-06-01

    Full Text Available In high voltage direct current (HVDC power transmission of offshore wind power systems, DC/DC converters are applied to transfer power from wind generators to HVDC terminals, and they play a crucial role in providing a high voltage gain, high efficiency, and high fault tolerance. This paper introduces an innovative multi-port DC/DC converter with multiple modules connected in a scalable matrix configuration, presenting an ultra-high voltage step-up ratio and low voltage/current rating of components simultaneously. Additionally, thanks to the adoption of active clamping current-fed push–pull (CFPP converters as sub-modules (SMs, soft-switching is obtained for all power switches, and the currents of series-connected CFPP converters are auto-balanced, which significantly reduce switching losses and control complexity. Furthermore, owing to the expandable matrix structure, the output voltage and power of a modular converter can be controlled by those of a single SM, or by adjusting the column and row numbers of the matrix. High control flexibility improves fault tolerance. Moreover, due to the flexible control, the proposed converter can transfer power directly from multiple ports to HVDC terminals without bus cable. In this paper, the design of the proposed converter is introduced, and its functions are illustrated by simulation results.

  13. Evaluation of SF6-alternative gas C5-PFK based on arc extinguishing performance and electric strength

    Science.gov (United States)

    Wu, Yi; Wang, Chunlin; Sun, Hao; Rong, Mingzhe; Murphy, Anthony Bruce; Li, Tianwei; Zhong, Jianying; Chen, Zhexin; Yang, Fei; Niu, Chunpin

    2017-09-01

    C5-PFK (C5-perfluoroketone, C5F10O) is under wide consideration as an environmentally-friendly alternative gas to SF6 in high-voltage applications, because of its superior insulation performance. The aim of this work is to study theoretically the arc extinguishing performance and electric strength of C5-PFK. The arc extinguishing performance of C5-PFK was evaluated by analyzing and comparing the thermophysical properties of C5-PFK, SF6, CF4, CO2 and N2 plasmas. It was difficult to obtain the species formed in C5-PFK plasmas because of the complex C5-PFK molecular decomposition process. In this work, the decomposition process of C5-PFK and the related species were analyzed by the bond energy analysis method. For the species for which parameters such as the partition function and the enthalpy of formation were not available, computational chemistry methods were used to obtain the required data. The collision integrals were calculated using the phenomenological potential model. Using these results, the local thermodynamic equilibrium composition at temperatures from 300 to 30 000 K at 1-10 atm of pure C5-PFK was calculated by the method of minimization of the Gibbs free energy, and the corresponding transport coefficients were calculated by Chapman-Enskog method. Through the comparison of the thermophysical properties, it was found that C5-PFK had similar characteristics to SF6, with large peaks in specific heat below 4500 K, indicating potentially good thermal interruption capability. However, the specific heat peak at 7000 K corresponding to CO decomposition may detract from the thermal interruption capability. Specific heat peaks at higher temperatures are associated with the breaking of double or triple bonds, and should be avoided if possible in the new alternative gases. The electric strength of C5-PFK was assessed using the molecular electrostatic potential, which can be accurately calculated or measured, and gives strong insights into important

  14. Transmission of power at high voltages

    Energy Technology Data Exchange (ETDEWEB)

    Lane, F J

    1963-01-01

    High voltage transmission is considered to be concerned with circuits and systems operating at or above 132 kV. While the general examination is concerned with ac transmission, dc systems are also included. The choice of voltage for a system will usually involve hazardous assessments of the future requirements of industry, commerce and a changing population. Experience suggests that, if the estimated economic difference between two voltages is not significant, there is good reason to choose the higher voltage, as this will make the better provision for unexpected future expansion. Two principal functions served by transmission circuits in a supply system are: (a) the transportation of energy in bulk from the generator to the reception point in the distribution system; and (b) the interconnection and integration of the generating plant and associated loads. These functions are considered and various types of system are discussed in terms of practicability, viability, quality and continuity of supply. Future developments requiring transmission voltages up to 750 kV will raise many problems which are in the main empirical. Examples are given of the type of problem envisaged and it is suggested that these can only be partially solved by theory and model operation.

  15. A 600kV 15mA Cockcroft-Walton high-voltage power supply with high stability and low-ripple voltage

    International Nuclear Information System (INIS)

    Su Tongling; Zhang Yimin; Chen Shangwen; Liu Yantong; Lv Huiyi; Liu Jiangtao

    2006-01-01

    A Cockcroft-Walton high-voltage power supply with high stability and low-ripple voltage has been developed. This power supply has been operated in a ns pulse neutron generator. The maximum non-load voltage is 600kV while the working voltage and load current are 550kV and 15mA, respectively. The tested results indicate that when the power supply is operated at 300kV, 6.7mA and the input voltage varies +/-10%, the long-term stability of the output voltage is S=(0.300-1.006)x10 -3 . The ripple voltage is δU P-P =6.2V at 300kV, 6.8-8.3mA and the ratio of δU P-P to the output voltage V H is δU P-P /V H =2.1x10 -5

  16. SF12: Stata module to alidate sf12 input and calculate sf12 version 2 t scores

    DEFF Research Database (Denmark)

    2015-01-01

    sf12 takes 12 variables in correct order (i1 i2a i2b i3a i3b i4a i4b i5 i6a i6b i6c i7), validate the variables with respect to sf12 requirements. Only rows that are correct are used for calculating the sf12 t scores....

  17. Stability of high current diode under 100-nanosecond-pulse voltage

    International Nuclear Information System (INIS)

    Lai Dingguo; Qiu Aici; Zhang Yongmin; Huang Jianjun; Ren Shuqing; Yang Li

    2012-01-01

    Stability of high current diode under pulse voltage with 80 ns and 34 ns rise time was studied on the flash Ⅱ accelerator. Influence of rise time of diode voltage on startup time and cathode emission uniformity and repeatability of diode impedance was analyzed by comparing the experimental results with numerically simulated results, and the influence mechanism was discussed. The startup time of diode increases with the increasing of rise time of voltage, and the repeatability of diode impedance decreases. Discal plane cathode is prone to emit rays intensely in the center area, the time that plasma covers the surface of the cathode increases and the shielding effect has more impact on cathode emission according to the increase of rise time. Local intense emission on the cathode increases expansion speed of plasma and reduces the effective emission area. The stability of characteristic impedance of diode under a pulse voltage with slow rise time is decreased by the combined action of expansion speed of plasma and the effective emission area. (authors)

  18. High Current, Low Voltage Power Converter [20kA, 6V] LHC Converter Prototype

    CERN Document Server

    Jørgensen, H E; Dupaquier, A; Fernqvist, G

    1998-01-01

    The superconducting LHC accelerator requires high currents (~12.5kA) and relatively low voltages (~10 V) for its magnets. The need to install the power converters underground is the driving force for reduced volume and high efficiency. Moreover, the LHC machine will require a very high level of performance from the power converters, particularly in terms of DC stability, dynamic response and also in matters of EMC. To meet these requirements soft-switching techniques will be used. This paper describes the development of a [20kA,6V] power converter intended as a stable high-current source for D CCT calibration and an evaluation prototype for the future LHC converters. The converter is made with a modular concept with five current sources [4kA,6V] in parallel. The 4kA sources are built as plu g-in modules: a diode rectifier on the AC mains with a damped L-C passive filter, a Zero Voltage Switching inverter working at 20 kHz and an output stage (high frequency transformers, Schottky rectifi ers and output filter...

  19. Mechanical strength and hydrophobicity of cotton fabric after SF{sub 6} plasma treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kamlangkla, K. [Nanoscience and Nanotechnology Program, Center of Innovative Nanotechnology, Chulalongkorn University, Bangkok 10330 (Thailand); Paosawatyanyong, B. [Department of Physics, Faculty of Science, Chulalongkorn University, and ThEP Center, Commission on Higher Education, Bangkok 10330 (Thailand); Pavarajarn, V. [Department of Chemical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok 10330 (Thailand); Hodak, Jose H. [Department of Physics, Faculty of Science, Mahidol University, Bangkok 10400 (Thailand); Hodak, Satreerat K., E-mail: Satreerat.H@Chula.ac.th [Department of Physics, Faculty of Science, Chulalongkorn University, and ThEP Center, Commission on Higher Education, Bangkok 10330 (Thailand)

    2010-08-01

    Surface treatments to tailor fabric properties are in high demand by the modern garment industry. We studied the effect of radio-frequency inductively coupled SF{sub 6} plasma on the surface characteristics of cotton fabric. The duration of the treatment and the SF{sub 6} pressure were varied systematically. We measured the hydrophobicity of treated cotton as a function of storage time and washing cycles. We used the weight loss (%) along with the etching rate, the tensile strength, the morphology changes and the hydrophobicity of the fabric as observables after treatments with different plasma conditions. The weight loss remains below 1% but it significantly increases when the treatment time is longer than 5 min. Substantial changes in the surface morphology of the fiber are concomitant with the increased etching rate and increased weight loss with measurable consequences in their mechanical characteristics. The measured water absorption time reaches the maximum of 210 min when the SF{sub 6} pressure is higher than 0.3 Torr. The water contact angle (149 deg.) and the absorption time (210 min) of cotton treated with extreme conditions appear to be durable as long as the fabric is not washed. X-ray photoelectron spectroscopy analysis reveals that the water absorption time of the fabric follows the same increasing trend as the fluorine/carbon ratio at the fabric surface and atom density of fluorine measured by Ar actinometer.

  20. Research on AutoCAD secondary development and function expansion based on VBA technology

    Science.gov (United States)

    Zhang, Runmei; Gu, Yehuan

    2017-06-01

    AutoCAD is the most widely used drawing tool among the similar design drawing products. In the process of drawing different types of design drawings of the same product, there are a lot of repetitive and single work contents. The traditional manual method uses a drawing software AutoCAD drawing graphics with low efficiency, high error rate and high input cost shortcomings and many more. In order to solve these problems, the design of the parametric drawing system of the hot-rolled I-beam (steel beam) cross-section is completed by using the VBA secondary development tool and the Access database software with large-capacity storage data, and the analysis of the functional extension of the plane drawing and the parametric drawing design in this paper. For the secondary development of AutoCAD functions, the system drawing work will be simplified and work efficiency also has been greatly improved. This introduction of parametric design of AutoCAD drawing system to promote the industrial mass production and related industries economic growth rate similar to the standard I-beam hot-rolled products.

  1. Relaxation effects in ionic mobility and cluster formation: negative ions in SF6 at high pressures

    International Nuclear Information System (INIS)

    Juarez, A M; De Urquijo, J; Hinojosa, G; Hernandez-Avila, J L; Basurto, E

    2010-01-01

    The relaxation effects of the ionic mobility and the formation of negative-ion clusters in SF 6 are studied in this work. For this purpose, we have measured the mobility of negative ions in SF 6 over the pressure range 100-800 Torr at a fixed value of density-normalized electric field, E/N, of 20 Td (1 Townsend = 10 -17 V cm 2 ). The data obtained show a clear dependence of the negative-ion drift velocity on drift distance. It is observed that the drift velocity (mobility) reaches a steady-state value only for drift distances above 2 cm, over the studied pressure range. In addition to this, we have observed that the ionic mobility depends strongly on the gas pressure. An explanation of this dependence of the ionic mobility on gas pressure is given in terms of a negative-ion clustering formation process. It was found that the assumption of a linear dependence of the cluster ion mass on pressure provides a satisfactory explanation for the observed mobilities.

  2. Prediction on dielectric strength and boiling point of gaseous molecules for replacement of SF6.

    Science.gov (United States)

    Yu, Xiaojuan; Hou, Hua; Wang, Baoshan

    2017-04-15

    Developing the environment-friendly insulation gases to replace sulfur hexafluoride (SF 6 ) has attracted considerable experimental and theoretical attentions but without success. A computational methodology was presented herein for prediction on dielectric strength and boiling point of arbitrary gaseous molecules in the purpose of molecular design and screening. New structure-activity relationship (SAR) models have been established by combining the density-dependent properties of the electrostatic potential surface, including surface area and the statistical variance of the surface potentials, with the molecular properties including polarizability, electronegativity, and hardness. All the descriptors in the SAR models were calculated using density functional theory. The substitution effect of SF 6 by various functional groups was studied systematically. It was found that CF 3 is the most effective functional group to improve the dielectric strength due to the large surface area and polarizability. However, all the substitutes exhibit higher boiling points than SF 6 because the molecular hardness decreases. The balance between E r and T b could be achieved by minimizing the local polarity of the molecules. SF 5 CN and SF 5 CFO were found to be the potent candidates to replace SF 6 in view of their large dielectric strengths and low boiling points. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. High-voltage picoamperemeter

    Energy Technology Data Exchange (ETDEWEB)

    Bugl, Andrea; Ball, Markus; Boehmer, Michael; Doerheim, Sverre; Hoenle, Andreas; Konorov, Igor [Technische Universitaet Muenchen, Garching (Germany); Ketzer, Bernhard [Technische Universitaet Muenchen, Garching (Germany); Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany)

    2014-07-01

    Current measurements in the nano- and picoampere region on high voltage are an important tool to understand charge transfer processes in micropattern gas detectors like the Gas Electron Multiplier (GEM). They are currently used to e.g. optimize the field configuration in a multi-GEM stack to be used in the ALICE TPC after the upgrade of the experiment during the 2nd long shutdown of the LHC. Devices which allow measurements down to 1pA at high voltage up to 6 kV have been developed at TU Muenchen. They are based on analog current measurements via the voltage drop over a switchable shunt. A microcontroller collects 128 digital ADC values and calculates their mean and standard deviation. This information is sent with a wireless transmitting unit to a computer and stored in a root file. A nearly unlimited number of devices can be operated simultaneously and read out by a single receiver. The results can also be displayed on a LCD directly at the device. Battery operation and the wireless readout are important to protect the user from any contact to high voltage. The principle of the device is explained, and systematic studies of their properties are shown.

  4. SF6 ventilation study at Agnew Lake Mines, Ontario

    International Nuclear Information System (INIS)

    1979-03-01

    In September 1978, James F. MacLaren Limited was awarded a contract by the Canada Centre for Mineral and Energy Technology (CANMET) to undertake a ventilation study at an underground uranium mine using sulphur hexafluoride (SF 6 ) as a tracer gas. The mine selected for the study was that of Agnew Lake Mines Limited in Northern Ontario. This is a relatively new mine with the combined mine/mill facilities first operational in mid-1977. Uranium is recovered from broken ore by in-situ leaching. The ventilation study was divided into two phases. A laboratory study was undertaken to develop a practical sampling technique, provide an evaluation of the logistics of long range sample transport and develop a laboratory analytical technique. Field programmes demonstrated the SF 6 tracer gas technique for mine ventilation trouble-shooting with the intent of providing information which will lead to more efficient use of existing mine ventilation capacity. This report outlines the findings of the laboratory study and the two field programmes

  5. Transport mechanisms for synoptic, seasonal and interannual SF6 variations and "age" of air in troposphere

    Directory of Open Access Journals (Sweden)

    K. Miyazaki

    2009-02-01

    Full Text Available We use an atmospheric general circulation model (AGCM driven chemistry-transport model (ACTM to simulate the evolution of sulfur hexafluoride (SF6 in the troposphere. The model results are compared with continuous measurements at 6 sites over 71° N–90° S. These comparisons demonstrate that the ACTM simulations lie within the measurement uncertainty over the analysis period (1999–2006 and capture salient features of synoptic, seasonal and interannual SF6 variability. To understand transport timescales of SF6 within the troposphere, transport times of air parcels from the surface to different regions of the troposphere ("age" are estimated from a simulation of an idealized tracer. The age estimation error and its sensitivity to the selection of reanalysis meteorology for ACTM nudging or the tracer transport by deep cumulus convection as represented in the model are discussed. Monthly-mean, 2-box model exchange times (τex are calculated from both the observed and simulated SF6 time series at the 6 observing sites and show favorable agreement, suggesting that the ACTM adequately represents large-scale interhemispheric transport. The simulated SF6 variability is further investigated through decomposition of the mixing ratio time-tendency into advective, convective, and vertical diffusive components. The transport component analysis illustrates the role of each process in SF6 synoptic variability at the site level and provides insight into the seasonality of τex.

  6. Test of Blanc's law for negative ion mobility in mixtures of SF6 with N2, O2 and air

    International Nuclear Information System (INIS)

    Hinojosa, G; Urquijo, J de

    2003-01-01

    We have measured the mobility of negative ion species drifting in mixtures of SF 6 with N 2 , O 2 and air. The pulsed Townsend experiment was used for this purpose. The conditions of the experiment, high pressures and low values of the reduced electric field, E/N, ensured that the majority species drifting in the gap was SF 6 - , to which the present mobilities are ascribed. The extrapolated, zero field mobilities for several mixture compositions were used to test them successfully with Blanc's law. Moreover, the measured zero field SF 6 - mobilities in air could also be explained in terms of the measured mobilities for this ionic species in N 2 and O 2

  7. Arc modelling in SF{sub 6} circuit breakers

    Energy Technology Data Exchange (ETDEWEB)

    Verite, J.C. [Electricite de France, Clamart (France). Derection des Etudes et Recherches; Boucher, T.; Comte, A. [Electricite de France, Moret sur Loing (France). Direction des Etudes et Recherches; Delalondre, C. [Electricite de France, Chatou (France). Direction des Etudes et Recherches; Robin-Jouan, P.; Serres, E.; Texier, V. [GEC Alsthom, Villeurbanne (France). Direction Technique Haute et Moyenne Tension; Barrault, M.; Chevrier, P.; Fievet, C. [CEA Centre d`Etudes Nucleaires de Grenoble, 38 (France). Merlin Gerin

    1995-06-01

    The paper presents the work done by an operator, EDF and two manufacturers to improve the physical models and numerical methods used to simulate the behavior of the plasma and cold gas around it in a breaking chamber of the HV SF6 circuit breaker, during the high-current phase. This work concerns flow phenomena, in particular incorporating compressibility and the study of turbulence, the coupling between these flow phenomena and electromagnetic phenomena, and finally, radiation - which plays an essential role in energy transfer during the high-current phase. For this latter aspect, emission but also absorption were proven to play a major role, and the two were introduced into the models. The paper presents the models developed and the results obtained with them for simulation of two circuit breaker mock-ups (a double-pressure circuit breaker mock-up and a self-expanding and rotating arc circuit breaker mock-up). (author) 10 refs.

  8. Verification of the sputter-generated {sup 32}SF{sub n}{sup −} (n = 1–6) anions by accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mane, R.G.; Surendran, P. [Nuclear Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Kumar, Sanjay [Physics Department, Agra College Agra, Agra 282002 (India); Nair, J.P.; Yadav, M.L. [Nuclear Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Hemalatha, M. [UM-DAE Centre for Excellence in Basic Sciences, Mumbai 400098 (India); Thomas, R.G.; Mahata, K. [Nuclear Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Kailas, S. [UM-DAE Centre for Excellence in Basic Sciences, Mumbai 400098 (India); Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India); Gupta, A.K., E-mail: anit@tifr.res.in [Nuclear Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2016-01-01

    Recently, we have performed systematic Secondary Ion Mass Spectrometry (SIMS) measurements at our ion source test set up and have demonstrated that gas phase {sup 32}SF{sub n}{sup −} (n = 1–6) anions for all size ‘n’ can be readily generated from a variety of surfaces undergoing Cs{sup +} ion sputtering in the presence of high purity SF{sub 6} gas by employing the gas spray-cesium sputter technique. In our SIMS measurements, the isotopic yield ratio {sup 34}SF{sub n}{sup −}/{sup 32}SF{sub n}{sup −} (n = 1–6) was found to be close to its natural abundance but not for all size ‘n’. In order to gain further insight into the constituents of these molecular anions, ultra sensitive Accelerator Mass Spectrometry (AMS) measurements were conducted with the most abundant {sup 32}SF{sub n}{sup −} (n = 1–6) anions, at BARC-TIFR 14 UD Pelletron accelerator. The results from these measurements are discussed in this paper.

  9. High voltage systems

    International Nuclear Information System (INIS)

    Martin, M.

    1991-01-01

    Industrial processes usually require electrical power. This power is used to drive motors, to heat materials, or in electrochemical processes. Often the power requirements of a plant require the electric power to be delivered at high voltage. In this paper high voltage is considered any voltage over 600 V. This voltage could be as high as 138,000 V for some very large facilities. The characteristics of this voltage and the enormous amounts of power being transmitted necessitate special safety considerations. Safety must be considered during the four activities associated with a high voltage electrical system. These activities are: Design; Installation; Operation; and Maintenance

  10. The effect of SF6 addition in a Cl2/Ar inductively coupled plasma for deep titanium etching

    Science.gov (United States)

    Laudrel, E.; Tillocher, T.; Meric, Y.; Lefaucheux, P.; Boutaud, B.; Dussart, R.

    2018-05-01

    Titanium is a material of interest for the biomedical field and more particularly for body implantable devices. Titanium deep etching by plasma was carried out in an inductively coupled plasma with a chlorine-based chemistry for the fabrication of titanium-based microdevices. Bulk titanium etch rate was first studied in Cl2/Ar plasma mixture versus the source power and the self-bias voltage. The plasma was characterized by Langmuir probe and by optical emission spectroscopy. The addition of SF6 in the plasma mixture was investigated. Titanium etch rate was optimized and reached a value of 2.4 µm · min-1. The nickel hard mask selectivity was also enhanced. The etched titanium surface roughness was reduced significantly.

  11. Impact of 10% SF6 Gas Compared to 100% Air Tamponade in Descemet's Membrane Endothelial Keratoplasty.

    Science.gov (United States)

    Rickmann, Annekatrin; Szurman, Peter; Jung, Sacha; Boden, Karl Thomas; Wahl, Silke; Haus, Arno; Boden, Katrin; Januschowski, Kai

    2018-04-01

    To compare the clinical outcomes following Descemet's membrane endothelial keratoplasty (DMEK) with 100% air tamponade versus 10% sulfur hexafluoride (SF 6 ) tamponade. Retrospective analysis of 108 consecutive DMEK cases subdivided by anterior chamber tamponade with 54 eyes receiving 10% SF 6 and 54 eyes receiving 100% air injection. A post-hoc matched analysis revealed no statistically significant differences between the groups. The main outcome measurements were the complication rate, including intra- and postoperative complications and graft detachment rate requiring re-bubbling. Clinical outcome included best-corrected visual acuity (BCVA), endothelial cell count (ECC), and central corneal thickness (CCT) measured 1, 3, and 6 months after DMEK surgery. The graft detachment rate with consecutive re-bubbling was 18.5% in the air group and 22.2% in the SF 6 group (p = 0.2). Remaining small peripheral graft detachments with a clear cornea occurred more often in the 100% air group (air: 22.2%; 12/54, 6/12 inferior compared to SF 6 : 7.4%; 4/54, 2/4 inferior; p = 0.06). The primary graft failure rate was comparable between the two groups. No complete graft detachment occurred. Outcome results for BCVA, ECC, and CCT at all follow-up time points were comparable between the two groups. The clinical outcomes (including re-bubbling rate, primary graft failure rate, and endothelial cell loss) were comparable with 100% air versus 10% SF 6 tamponade, whereas other studies suggest that a higher SF 6 concentration (20%) may result in a lower re-bubbling rate.

  12. Modification in existing SF6 gas handling system at 14UD BARC-TIFR Pelletron Accelerator, Mumbai

    International Nuclear Information System (INIS)

    Ninawe, N.G.; Gupta, S.K.; Ramjilal; Sparrow, Hillary; Sharma, S.C.; Bhagwat, P.V.; Salvi, S.B.

    2003-01-01

    BARC-TIFR 14 UD Pelletron Accelerator facility at TIFR, Mumbai is operational since inception 1989. The accelerator is housed inside a pressure vessel of 6 metre diameter, 25 metre long and 525m 3 volume. The accelerator tank is pressurized with SF 6 at 80 to 100 psig in order to achieve 14MV. The inventory of SF 6 gas is about 18,000 Kg (approximately) at 80 psig. SF 6 gas can be transported from Accelerator tank to storage tank using gas handling system, which consists of oil free compressor, vacuum pump, dust filters, oil filters, dryers etc

  13. The relationship between SF-6D utility scores and lifestyle factors across three life stages: evidence from the Australian Longitudinal Study on Women's Health.

    Science.gov (United States)

    Kanesarajah, Jeeva; Waller, Michael; Whitty, Jennifer A; Mishra, Gita D

    2017-06-01

    To investigate how SF-6D utility scores change with age between generations of women and to quantify the relationship of SF-6D with lifestyle factors across life stages. Up to seven waves of self-reported, longitudinal data were drawn for the 1973-1978 (young, N = 13772), 1946-1951 (mid-age, N = 12792), 1921-1926 (older, N = 9972) cohorts from the Australian Longitudinal Study on Women's Health. Mixed effects models were employed for analysis. Young and mid-age women had similar average SF-6D scores at baseline (0.63-0.64), which remained consistent over the 16-year period. However, older women had lower scores at baseline at 0.57 which steadily declined over 15 years. Across cohorts, low education attainment, greater difficulty in managing income, obesity, physical inactivity, heavy smoking, no alcohol consumption, and increasing stress levels were associated with lower SF-6D scores. The magnitude of effect varied between cohorts. SF-6D scores were lower amongst young women with high-risk drinking behaviours than low-risk drinkers. Mid-age women, who were underweight, never married, or underwent surgical menopause also reported lower SF-6D scores. Older women who lived in remote areas, who were ex-smokers, or were underweight, reported lower SF-6D scores. The SF-6D utility score is sensitive to differences in lifestyle factors across adult life stages. Gradual loss of physical functioning may explain the steady decline in health for older women. Key factors associated with SF-6D include physical activity, body mass index, menopause status, smoking, alcohol use, and stress. Factors associated with poorer SF-6D scores vary in type and magnitude at different life stages.

  14. Amorphous hydrogenated carbon films treated by SF{sub 6} plasma

    Energy Technology Data Exchange (ETDEWEB)

    Marins, N M S; Mota, R P; Santos, D C R; Honda, R Y; Kayama, M E; Kostov, K G; Algatti, M A [Laboratorio de Plasma, Faculdade de Engenharia, UNESP, Av. Dr. Ariberto Pereira da Cunha-333, 12516-410, Guaratingueta, SP (Brazil); Cruz, N C; Rangel, E C, E-mail: nazir@feg.unesp.b [Laboratorio de Plasmas Tecnologicos, Unidade Diferenciada Sorocaba/Ipero, UNESP, Av. Tres de Marco-511, 18085-180, Sorocaba, SP (Brazil)

    2009-05-01

    This work was performed to verify the chemical structure, mechanical and hydrophilic properties of amorphous hydrogenated carbon films prepared by plasma enhanced chemical vapor deposition, using acetylene/argon mixture as monomer. Films were prepared in a cylindrical quartz reactor, fed by 13.56 MHz radiofrequency. The films were grown during 5 min, for power varying from 25 to 125 W at a fixed pressure of 9.5 Pa. After deposition, all samples were treated by SF{sub 6} plasma with the aim of changing their hydrophilic character. Film chemical structure investigated by Raman spectroscopy, revealed the increase of sp{sup 3} hybridized carbon bonds as the plasma power increases. Hardness measurements performed by the nanoindentation technique showed an improvement from 5 GPa to 14 GPa following the increase discharge power. The untreated films presented a hydrophilic character, which slightly diminished after SF{sub 6} plasma treatment.

  15. Development of high voltage surge limiting resistor for protection of HV multiplier of 3 MeV DC accelerator

    International Nuclear Information System (INIS)

    Dewangan, S.; Sharma, D.K.; Bakhtsingh, R.I.

    2013-01-01

    A 3MeV, 10mA DC electron beam accelerator is in commissioning stages at EBC, Kharghar, Navi Mumbai. The accelerating potential of -3MV is generated by a Parallel Coupled Voltage Multiplier (PCVM) scheme using 74 stages of HV rectifier stacks in the 6 kg/cm 2 SF6 gas environment. The HV surges of order of 600kV, 42kA, 10ns is estimated across the rectifier stacks during sparking in the multiplier column. To limit the surge current and protect the rectifier diodes, a non inductive thick film surge limiting resistor (SLR) and protective spark gap is designed and developed. The rectifier stacks with surge limiting resistors at both the ends and protective spark gap in parallel has been successfully tested in simulated surge condition at an impulse voltage of 212kVp, 150ns FWHM and surge energy of 200J, 10ms, 20kV at 6kg/cm 2 SF6 gas environment and found satisfactorily. Subsequently the HV multiplier was installed with this surge protection scheme and is being tested at 1.2 MeV level. This paper describes the design features and test results of the non-inductive surge limiting resistor. (author)

  16. Apparatus with a cooled X-ray source and a high voltage generator

    Energy Technology Data Exchange (ETDEWEB)

    1977-02-01

    Apparatus, especially for a dental application, with an X-ray source and a high voltage generator, whereby the X-ray source and a high voltage generator are contained in a housing, which is filled with a coolant medium, characterised by the housing being divided into two chambers, whereby the X-ray source is in the first chamber and the high voltage generator is in the second chamber and between the chambers a dividing wall is placed for the screening of the X-ray irradiation from the first chamber from the second, whereby at least one of the walls of the second chamber is elastic to accommodate the expansion of the coolant medium.

  17. Passive Q-switching in CW-CO2 laser with SF6 as an intracavity saturable absorber

    International Nuclear Information System (INIS)

    Al-Hawat, Sh.

    2007-10-01

    A passive Q-switching was applied to a tunable CW CO 2 laser with output power about 3.5 W using SF 6 as a saturable absorber inside the cavity. The Q-Switching phenomenon was studied ( pulse shape, pulse duration, repetition rate and conditions of its generation ) at the spectral lines of 10P(10), 10P(26), 10P(28) and 10P(30) from the branch of 10P of CO 2 laser. These lines had a weak absorption in relation to other lines of this branch, under SF 6 pressure till 0.5 mbar. To control the behaviour of such phenomenon, the gases He and Xe were added separately to SF 6 . It was observed that the Q-switching phenomenon was depended on the added gas pressure of Xe and He, through the repetitive rate of pulses , duration and energy of generated laser pulse. A computational program was written to calculate the Q-switching pulses parameters under similar conditions as those applied in the case of SF 6 +He mixture. A comparison was made with the experimental data , not so big discrepancies were observed between them. In addition to that, absorption coefficients of SF 6 were determined in two cases: the first one when the absorption cell was located outside the laser cavity, and the second one when the cell was located inside the cavity. On the basis of obtained coefficients the absorption cross sections of SF 6 were found and compared with NIST database.(author)

  18. Estimating health state utility values for comorbid health conditions using SF-6D data.

    Science.gov (United States)

    Ara, Roberta; Brazier, John

    2011-01-01

    When health state utility values for comorbid health conditions are not available, data from cohorts with single conditions are used to estimate scores. The methods used can produce very different results and there is currently no consensus on which is the most appropriate approach. The objective of the current study was to compare the accuracy of five different methods within the same dataset. Data collected during five Welsh Health Surveys were subgrouped by health status. Mean short-form 6 dimension (SF-6D) scores for cohorts with a specific health condition were used to estimate mean SF-6D scores for cohorts with comorbid conditions using the additive, multiplicative, and minimum methods, the adjusted decrement estimator (ADE), and a linear regression model. The mean SF-6D for subgroups with comorbid health conditions ranged from 0.4648 to 0.6068. The linear model produced the most accurate scores for the comorbid health conditions with 88% of values accurate to within the minimum important difference for the SF-6D. The additive and minimum methods underestimated or overestimated the actual SF-6D scores respectively. The multiplicative and ADE methods both underestimated the majority of scores. However, both methods performed better when estimating scores smaller than 0.50. Although the range in actual health state utility values (HSUVs) was relatively small, our data covered the lower end of the index and the majority of previous research has involved actual HSUVs at the upper end of possible ranges. Although the linear model gave the most accurate results in our data, additional research is required to validate our findings. Copyright © 2011 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  19. Ion and electron swarm studies of relevance to plasma processing: positive ion-molecule and electron-molecule studies of SF6 and derivatives

    International Nuclear Information System (INIS)

    Atterbury, C.; Kennedy, R.A.; Critchley, A.D.J.; Mayhew, C.A.

    2002-01-01

    Many sequential and parallel chemical reactions involving charged species occur in a plasma. Data needed to model plasma's chemical and physical environment includes cross-section, rate coefficients, and product ion distribution of electron-molecule and ion-molecule processes. Such reactions are studied by our group away from the complexity of the plasma environment, with experimental techniques that allow us to concentrate on a single process, where usually only one or two species are involved. A molecule commonly used in plasma etching applications is SF 6 1,2 . We have performed a series of positive ion-molecule and electron attachment studies on SF 6 and related molecules, including SeF 6 , TeF 6 (i.e. XF 6 molecules), SF 5 CF 3 and SF 5 Cl (i.e. SF 5 X molecules) 3- (. The studies of ion reactions with and electron attachment to SF 6 and physically similar molecules are of value when seeking to understand the ion and electron chemistry occurring in SF 6 containing plasma. The result of these studies are presented in this poster. Ion-molecule reactions. Rate coefficients and ion product branching ratios have been determined with the Selected Ion Flow Tube (SIFT) at room temperature (300 K) for reactions of SF 5 X with the following twenty-two cations; Ne + , F + , Ar + , N 2 + , N + , CO + , CO 2 + , O + , N 2 O + , O 2 + , SF 4 + , CF 2 + , SF + , SF 2 + , NO 2 + , SF 5 + , NO + , CF + , CF 3 + , SF 3 + , and H 3 O + (listed in order of decreasing recombination energy). SF 2 + , NO 2 + , NO + , SF 3 + , and H 3 O + are found to be unreacted with both SF 5 CF 3 and SF 5 Cl. The majority of the other reactions proceed with rate coefficients that are close to the capture value. Those found to occur at rates significantly less than the capture mechanism value re the reactions of O 2 + , SF + , SF 5 + , and CF 3 + with SF 5 CF 3 , and SF 4 + and SF 5 + with SF 5 Cl. Several distinction processes are observed among the large number of reactions studied, including

  20. High voltage engineering

    CERN Document Server

    Rizk, Farouk AM

    2014-01-01

    Inspired by a new revival of worldwide interest in extra-high-voltage (EHV) and ultra-high-voltage (UHV) transmission, High Voltage Engineering merges the latest research with the extensive experience of the best in the field to deliver a comprehensive treatment of electrical insulation systems for the next generation of utility engineers and electric power professionals. The book offers extensive coverage of the physical basis of high-voltage engineering, from insulation stress and strength to lightning attachment and protection and beyond. Presenting information critical to the design, selec

  1. Leader propagation in uniform background fields in SF6

    International Nuclear Information System (INIS)

    Seeger, M; Niemeyer, L; Bujotzek, M

    2009-01-01

    The breakdown mechanism of compressed SF 6 in gas insulation is known to be controlled by stepped leader propagation. This process is still not well understood in uniform and weakly non-uniform background fields with small electrode protrusions, such as particles or surface roughness. In a previous publication an investigation of partial discharges and breakdown in uniform background fields that focused on streamer and leader inception mechanisms was presented (Seeger et al 2008 J. Phys. D: Appl. Phys. 41 185204). In this paper we present for the first time a physical leader propagation model that consistently describes the observed phenomena in uniform background fields in SF 6 . The model explains two different types of leader breakdown; these can be associated with the precursor and the stem mechanisms. It also yields the parameters of stepped leader propagation, which include step lengths, associated step charges, step times and fields and temperatures in the leader channel. Further, it explains the features of arrested leaders in uniform background fields. The model predicts the range of parameters under which arrested and breakdown leaders occur in good agreement with the experimental data.

  2. Predicting SF-6D utility scores from the Oswestry disability index and numeric rating scales for back and leg pain.

    Science.gov (United States)

    Carreon, Leah Y; Glassman, Steven D; McDonough, Christine M; Rampersaud, Raja; Berven, Sigurd; Shainline, Michael

    2009-09-01

    Cross-sectional cohort. The purpose of this study is to provide a model to allow estimation of utility from the Short Form (SF)-6D using data from the Oswestry Disability Index (ODI), Back Pain Numeric Rating Scale (BPNRS), and the Leg Pain Numeric Rating Scale (LPNRS). Cost-utility analysis provides important information about the relative value of interventions and requires a measure of utility not often available from clinical trial data. The ODI and numeric rating scales for back (BPNRS) and leg pain (LPNRS), are widely used disease-specific measures for health-related quality of life in patients with lumbar degenerative disorders. The purpose of this study is to provide a model to allow estimation of utility from the SF-6D using data from the ODI, BPNRS, and the LPNRS. SF-36, ODI, BPNRS, and LPNRS were prospectively collected before surgery, at 12 and 24 months after surgery in 2640 patients undergoing lumbar fusion for degenerative disorders. Spearman correlation coefficients for paired observations from multiple time points between ODI, BPNRS, and LPNRS, and SF-6D utility scores were determined. Regression modeling was done to compute the SF-6D score from the ODI, BPNRS, and LPNRS. Using a separate, independent dataset of 2174 patients in which actual SF-6D and ODI scores were available, the SF-6D was estimated for each subject and compared to their actual SF-6D. In the development sample, the mean age was 52.5 +/- 15 years and 34% were male. In the validation sample, the mean age was 52.9 +/- 14.2 years and 44% were male. Correlations between the SF-6D and the ODI, BPNRS, and LPNRS were statistically significant (P < 0.0001) with correlation coefficients of 0.82, 0.78, and 0.72, respectively. The regression equation using ODI, BPNRS,and LPNRS to predict SF-6D had an R of 0.69 and a root mean square error of 0.076. The model using ODI alone had an R of 0.67 and a root mean square error of 0.078. The correlation coefficient between the observed and estimated

  3. Study of protection devices against the effects of electric discharges inside a very high voltage generator: the Vivitron accelerator; Etude de dispositifs de protection contre les effets des decharges electriques au sein d`un generateur de tres haute tension: l`accelerateur Vivitron

    Energy Technology Data Exchange (ETDEWEB)

    Nolot, E

    1996-10-31

    The Vivitron tandem is a large electrostatic accelerator comprising a Van de Graaff generator designed to reach terminal voltages of around 30 MV. The machine is limited at rather lower nominal voltages (about 20 MV) due to the sensitivity of the insulating column structure to transient overvoltages. These are induced by electrical discharges in compressed SF{sub 6}. This thesis first aims at analysing the fundamental reasons of electrical discharges in order to limit the probability of their occurrence. Then we simulate the transient overvoltages induced and present some improvements which may lead to a stable behaviour of the Vivitron at nominal voltages higher than 20 MV. Initially we deduce discharge onset voltages and actual breakdown field limitations in the different gap geometries from analysis of possible breakdown mechanisms in compressed SF{sub 6}. In a second part, some electrical characteristics of the insulating column structure are measured at high voltage. Fast rising oscillating waves induced by sparking in the Vivitron, along with the associated energies,are determined in the third part. The last part deals with new surge protections of the insulating column structure. Spark gaps with precise onset voltage and optimized shielding electrodes are discussed. ZnO-based varistors designed for operation at very high fields have also been developed in order to reduce transient overvoltage values. (author). 122 refs.

  4. SF6 gas insulated power substations. Effects of fast transients (VFT) on the equipment and adjacent equipment of the Itaipu Binacional SF6 insulated power substations; Subestaciones aisladas a gas SF6. Efectos de los transitorios rapidos (VFT's) sobre equipos y equipos adyacentes de las SE's SF6 de Itaipu Binacional

    Energy Technology Data Exchange (ETDEWEB)

    Santacruz Martinez, Miguel [Usina Hidroelectrica de Itaipu, Assuncao (Paraguay)]. E-mail: santcruz@itaipu.gov.py

    2001-07-01

    With the operation starting of the S F6 gas substations in high voltage systems occurs a new form of overvoltage presently known as Very Fast Transients. This paper aims the phenomenon characterization, defining the origins and the behaviour of the electric systems, and briefly presents the damages caused by the phenomenon on the equipment and adjacent equipment of S F6 gas insulated substations of the Itaipu Binacional, mainly on the power transformers and oil/S F6 isolators of the step-up transformers. These equipment was modified or are been modified as a consequence of the this overvoltage effects.

  5. Ozone depleting substances and gases HFCs, PFCs and SF{sub 6}. Consumption and emissions 2003; Ozonlagsnedbrydende stoffer og drivhusgasserne HFC'er PFC'er og SF6. Forbrug og emissioner 2003

    Energy Technology Data Exchange (ETDEWEB)

    Sander Poulsen, T.

    2005-07-01

    The evaluation includes a calculation of actual emissions of HFCs, PFCs and SF{sub 6} in Denmark. In this calculation of actual emissions, the release from stock of greenhouse gases in products has been taken into account, and adjustments have been made for imports and exports of the greenhouse gases in products. The evaluation has partly been prepared to enable Denmark to fulfil its international obligations to provide information within this area, and partly to follow the trend in consumption and emissions of HFCs, PFCs and SF{sub 6}. (BA)

  6. Exome-wide association study identifies a TM6SF2 variant that confers susceptibility to nonalcoholic fatty liver disease

    DEFF Research Database (Denmark)

    Kozlitina, Julia; Smagris, Eriks; Stender, Stefan

    2014-01-01

    Nonalcoholic fatty liver disease (NAFLD) is the most common form of liver disease. To elucidate the molecular basis of NAFLD, we performed an exome-wide association study of liver fat content. Three variants were associated with higher liver fat levels at the exome-wide significance level of 3.......6 × 10(-7): two in PNPLA3, an established locus for NAFLD, and one (encoding p.Glu167Lys) in TM6SF2, a gene of unknown function. The TM6SF2 variant encoding p.Glu167Lys was also associated with higher circulating levels of alanine transaminase, a marker of liver injury, and with lower levels of low...... knockdown of Tm6sf2 in mice increased liver triglyceride content by threefold and decreased very-low-density lipoprotein (VLDL) secretion by 50%. Taken together, these data indicate that TM6SF2 activity is required for normal VLDL secretion and that impaired TM6SF2 function causally contributes to NAFLD....

  7. Molecular bonding in SF6 measured by elastic electron scattering

    International Nuclear Information System (INIS)

    Miller, J.D.; Fink, M.

    1992-01-01

    Elastic differential cross-section measurements of gaseous SF 6 were made with 30 keV electrons in the range of 0.25 bohrs -1 ≤s≤10 bohrs -1 . Structural parameters derived in this study closely matched those found in an earlier total (elastic plus inelastic) scattering investigation. Multiple-scattering effects were incorporated in the structural refinement. The discrepancies between the independent atom model and the measured differential cross section reproduce earlier total scattering results for momentum transfers of greater than 5 bohrs -1 . By extending the measurements to smaller s values, a closer examination of a Hartree--Fock calculation for SF 6 was possible. It was found that the difference curve obtained from the Hartree--Fock calculation matched the experimental data in this region. A more quantitative analysis was performed using the analytic expressions of Bonham and Fink to compute moments of the molecular charge distribution from the differential cross-section data. Comparison of these results with similar fits to the Hartree--Fock calculation confirmed the good agreement between the Hartree--Fock calculation and the current elastic data

  8. Determining Health-Related Quality-of-Life Outcomes Using the SF-6D Following Total Hip Arthroplasty.

    Science.gov (United States)

    Elmallah, Randa K; Chughtai, Morad; Adib, Farshad; Bozic, Kevin J; Kurtz, Steven M; Mont, Michael A

    2017-03-15

    Following total hip arthroplasty, patients' perception of their postoperative improvement and health plays a large role in satisfaction with and success of the surgical procedure. The Short Form-6D (SF-6D) is a health-related quality-of-life measure that assigns numerical value to the perception of patients' own health. The purpose was to determine SF-6D values of patients after total hip arthroplasty, to determine whether score changes were clinically relevant, and to compare these with postoperative functional improvements. We evaluated 188 patients who underwent primary total hip arthroplasty at 7 institutions and who had a mean age of 69 years (range, 47 to 88 years) and a mean body mass index of 28.8 kg/m (range, 19.8 to 38.9 kg/m). The SF-6D values were obtained from patients' SF-36 scores, and clinical relevance of value changes was determined using effect size. Using previous research, effect sizes were considered small between 0.2 and 0.5, moderate between 0.6 to 0.8, and large at >0.8. Clinical correlation was assessed using the Lower-Extremity Activity Scale and Harris hip scores. Patients were assessed preoperatively and postoperatively at 6 months and 1, 2, 3, and 5 years. The SF-6D scores improved from preoperatively and achieved significance (p < 0.05) at all points. The effect size demonstrated good clinical relevance up to the latest follow-up: 1.27 at 6 months, 1.30 at 1 year, 1.07 at 2 years, 1.08 at 3 years, and 1.05 at 5 years. The Lower-Extremity Activity Scale improved at all follow-up points from preoperatively to 1.8 at 6 months, 2.0 at 1 year, 1.8 at 2 years, 1.5 at 3 years, and 1.6 points at 5 years. The Harris hip score improved to 38 points at 6 months, 40 points at 1 year, 38 points at 2 years, 39 points at 3 years, and 41 points at 5 years postoperatively. The improvements in the Lower-Extremity Activity Scale and the Harris hip score significantly positively correlated (p < 0.01) with the SF-6D scores at all time points. SF-6D scores

  9. Technological Aspects: High Voltage

    CERN Document Server

    Faircloth, D.C.

    2013-12-16

    This paper covers the theory and technological aspects of high-voltage design for ion sources. Electric field strengths are critical to understanding high-voltage breakdown. The equations governing electric fields and the techniques to solve them are discussed. The fundamental physics of high-voltage breakdown and electrical discharges are outlined. Different types of electrical discharges are catalogued and their behaviour in environments ranging from air to vacuum are detailed. The importance of surfaces is discussed. The principles of designing electrodes and insulators are introduced. The use of high-voltage platforms and their relation to system design are discussed. The use of commercially available high-voltage technology such as connectors, feedthroughs and cables are considered. Different power supply technologies and their procurement are briefly outlined. High-voltage safety, electric shocks and system design rules are covered.

  10. Light-induced lattice expansion leads to high-efficiency perovskite solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, Hsinhan; Asadpour, Reza; Blancon, Jean-Christophe; Stoumpos, Constantinos C.; Durand, Olivier; Strzalka, Joseph W.; Chen, Bo; Verduzco, Rafael; Ajayan, Pulickel M.; Tretiak, Sergei; Even, Jacky; Alam, Muhammad Ashraf; Kanatzidis, Mercouri G.; Nie, Wanyi; Mohite, Aditya D.

    2018-04-05

    Hybrid-perovskite based high-performance optoelectronic devices and clues from their operation has led to the realization that light-induced structural dynamics play a vital role on their physical properties, device performance and stability. Here, we report that continuous light illumination leads to a uniform lattice expansion in hybrid perovskite thin-films, which is critical for obtaining high-efficiency photovoltaic devices. Correlated, in-situ structural and device characterizations reveal that light-induced lattice expansion significantly benefits the performances of a mixed-cation pure-halide planar device, boosting the power conversion efficiency from 18.5% to 20.5%. This is a direct consequence of the relaxation of local lattice strains during lattice expansion, which results in the reduction of the energetic barriers at the perovskite/contact interfaces in devices, thus improving the open circuit voltage and fill factor. The light-induced lattice expansion stabilizes these high-efficiency photovoltaic devices under continuous operation of full-spectrum 1-Sun illumination for over 1500 hours. One Sentence Summary: Light-induced lattice expansion improves crystallinity, relaxes lattice strain, which enhances photovoltaic performance in hybrid perovskite device.

  11. BOREAS TGB-1 NSA SF6 Chamber Flux Data

    Science.gov (United States)

    Crill, Patrick; Varner, Ruth K.; Hall, Forrest G. (Editor); Conrad, Sara K. (Editor)

    2000-01-01

    The BOREAS TGB-1 team made several chamber and tower measurements of trace gases at sites in the BOREAS NSA. This data set contains sulfur hexafluoride (SF6) dark chamber flux measurements at the NSA-OJP and NSA-YJP sites from 16-May through 13-Sep-1994. Gas samples were extracted approximately every 7 days from dark chambers and analyzed at the NSA lab facility. The data are provided in tabular ASCII files.

  12. Low-profile high-voltage compact gas switch

    International Nuclear Information System (INIS)

    Goerz, D.A.; Wilson, M.J.; Speer, R.D.

    1997-01-01

    This paper discusses the development and testing of a low-profile, high-voltage, spark-gap switch designed to be closely coupled with other components into an integrated high-energy pulsed-power source. The switch is designed to operate at 100 kV using SF6 gas pressurized to less than 0.7 MPa. The volume of the switch cavity region is less than 1.5 cm3, and the field stress along the gas-dielectric interface is as high as 130 kV/cm. The dielectric switch body has a low profile that is only I -cm tall at its greatest extent and nominally 2-mm thick over most of its area. This design achieves a very low inductance of less than 5 nH, but results in field stresses exceeding 500 kV/cm in the dielectric material. Field modeling was done to determine the appropriate shape for the highly stressed insulator and electrodes, and special manufacturing techniques were employed to mitigate the usual mechanisms that induce breakdown and failure in solid dielectrics. Static breakdown tests verified that the switch operates satisfactorily at 100 kV levels. The unit has been characterized with different shaped electrodes having nominal gap spacings of 2.0, 2.5, and 3.0 mm. The relationship between self-break voltage and operating pressure agrees well with published data on gas properties, accounting for the field enhancements of the electrode shapes being used. Capacitor discharge tests in a low inductance test fixture exhibited peak currents up to 25 kA with characteristic frequencies of the ringdown circuit ranging from 10 to 20 MHz. The ringdown waveforms and scaling of measured parameters agree well with circuit modeling of the switch and test fixture. Repetitive operation has been demonstrated at moderate rep-rates up to 15 Hz, limited by the power supply being used. Preliminary tests to evaluate lifetime of the compact switch assembly have been encouraging. In one case, after more than 7,000 high-current ringdown tests with approximately 30 C of total charge transferred, the

  13. Global distribution of mean age of stratospheric air from MIPAS SF6 measurements

    Directory of Open Access Journals (Sweden)

    H. Fischer

    2008-02-01

    Full Text Available Global distributions of profiles of sulphur hexafluoride (SF6 have been retrieved from limb emission spectra recorded by the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS on Envisat covering the period September 2002 to March 2004. Individual SF6 profiles have a precision of 0.5 pptv below 25 km altitude and a vertical resolution of 4–6 km up to 35 km altitude. These data have been validated versus in situ observations obtained during balloon flights of a cryogenic whole-air sampler. For the tropical troposphere a trend of 0.230±0.008 pptv/yr has been derived from the MIPAS data, which is in excellent agreement with the trend from ground-based flask and in situ measurements from the National Oceanic and Atmospheric Administration Earth System Research Laboratory, Global Monitoring Division. For the data set currently available, based on at least three days of data per month, monthly 5° latitude mean values have a 1σ standard error of 1%. From the global SF6 distributions, global daily and monthly distributions of the apparent mean age of air are inferred by application of the tropical tropospheric trend derived from MIPAS data. The inferred mean ages are provided for the full globe up to 90° N/S, and have a 1σ standard error of 0.25 yr. They range between 0 (near the tropical tropopause and 7 years (except for situations of mesospheric intrusions and agree well with earlier observations. The seasonal variation of the mean age of stratospheric air indicates episodes of severe intrusion of mesospheric air during each Northern and Southern polar winter observed, long-lasting remnants of old, subsided polar winter air over the spring and summer poles, and a rather short period of mixing with midlatitude air and/or upward transport during fall in October/November (NH and April/May (SH, respectively, with small latitudinal gradients, immediately before the new polar vortex starts to form. The mean age distributions further

  14. Structural evolution of the P22-like phages: Comparison of Sf6 and P22 procapsid and virion architectures

    Energy Technology Data Exchange (ETDEWEB)

    Parent, Kristin N. [University of California, San Diego, Department of Chemistry and Biochemistry, La Jolla, CA 92093 (United States); Gilcrease, Eddie B. [University of Utah School of Medicine, Division of Microbiology and Immunology, Department of Pathology, Salt Lake City, UT 84112 (United States); Casjens, Sherwood R., E-mail: sherwood.casjens@path.utah.edu [University of Utah School of Medicine, Division of Microbiology and Immunology, Department of Pathology, Salt Lake City, UT 84112 (United States); Baker, Timothy S., E-mail: tsb@ucsd.edu [University of California, San Diego, Department of Chemistry and Biochemistry, La Jolla, CA 92093 (United States); University of California, San Diego, Division of Biological Sciences, La Jolla, CA 92093 (United States)

    2012-06-05

    Coat proteins of tailed, dsDNA phages and in herpesviruses include a conserved core similar to the bacteriophage HK97 subunit. This core is often embellished with other domains such as the telokin Ig-like domain of phage P22. Eighty-six P22-like phages and prophages with sequenced genomes share a similar set of virion assembly genes and, based on comparisons of twelve viral assembly proteins (structural and assembly/packaging chaperones), these phages are classified into three groups (P22-like, Sf6-like, and CUS-3-like). We used cryo-electron microscopy and 3D image reconstruction to determine the structures of Sf6 procapsids and virions ({approx} 7 A resolution), and the structure of the entire, asymmetric Sf6 virion (16-A resolution). The Sf6 coat protein is similar to that of P22 yet it has differences in the telokin domain and in its overall quaternary organization. Thermal stability and agarose gel experiments show that Sf6 virions are slightly less stable than those of P22. Finally, bacterial host outer membrane proteins A and C were identified in lipid vesicles that co-purify with Sf6 particles, but are not components of the capsid.

  15. Technological Aspects: High Voltage

    International Nuclear Information System (INIS)

    Faircloth, D C

    2013-01-01

    This paper covers the theory and technological aspects of high-voltage design for ion sources. Electric field strengths are critical to understanding high-voltage breakdown. The equations governing electric fields and the techniques to solve them are discussed. The fundamental physics of high-voltage breakdown and electrical discharges are outlined. Different types of electrical discharges are catalogued and their behaviour in environments ranging from air to vacuum are detailed. The importance of surfaces is discussed. The principles of designing electrodes and insulators are introduced. The use of high-voltage platforms and their relation to system design are discussed. The use of commercially available high-voltage technology such as connectors, feedthroughs and cables are considered. Different power supply technologies and their procurement are briefly outlined. High-voltage safety, electric shocks and system design rules are covered. (author)

  16. Early Stages of Pulsed-Laser Growth of Silicon Microcolumns and Microcones in Air and SF6

    International Nuclear Information System (INIS)

    Fowlkes, J.D.; Lowndes, D.H.; Pedraza, A.J.

    1999-01-01

    Dense arrays of high-aspect-ratio silicon microcolumns and microcones are formed by cumulative nanosecond pulsed excimer laser irradiation of single-crystal silicon in oxidizing atmospheres such as air and SF 6 . Growth of such surface microstructures requires a redeposition model and also involves elements of self-organization. The shape of the microstructures, i.e. straight columns vs steeply sloping cones and connecting walls, is governed by the type and concentration of the oxidizing species, e.g. oxygen vs fluorine. Growth is believed to occur by a catalyst-free VLS (vapor-liquid-solid) mechanism that involves repetitive melting of the tips of the columns/cones and deposition there of the ablated flux of Si-containing vapor. Results are presented of a new investigation of how such different final microstructures as microcolumns or microcones joined by walls nucleate and develop. The changes in silicon surface morphology were systematically determined and compared as the number of pulsed KrF (248 nm) laser shots was increased from 25 to several thousand in both air and SF 6 . The experiments in air and SF 6 reveal significant differences in initial surface cracking and pattern formation. Consequently, local protrusions are first produced and column or cone/wall growth is initiated by different processes and at different rates. Differences in the spatial organization of column or cone/wall growth also are apparent

  17. Ultraviolet differential optical absorption spectrometry: quantitative analysis of the CS2 produced by SF6 decomposition

    International Nuclear Information System (INIS)

    Zhang, Xiaoxing; Zhou, Hong; Cui, Zhaolun; Xiao, Song; Tang, Ju; Chen, Chuan; Li, Xin

    2017-01-01

    The occurrence of partial discharge or partial overthermal fault in sulfur hexafluoride (SF 6 )-insulated electrical equipment frequently causes SF 6 and solid insulation materials to decompose into various products. One of the most characteristic products of this process is carbon disulfide (CS 2 ). The internal fault type and severity of the fault in the insulation equipment can be detected through the accurate quantitative detection of CS 2 . A device for simultaneously determining and quantifying gaseous CS 2 via ultraviolet differential optical absorption spectrometry is developed in this study. A Sym14 wavelet transform and fast Fourier transform (FFT) are applied to process the spectral data of the feature regions, namely 190 nm to 210 nm. The concentration of CS 2 is determined, and the detection limit of the developed device is identified. A good linear relationship is observed between the characteristic peaks of FFT and the concentration of CS 2 after the operational parameters are optimized. Along the light path at 600 mm, the average detection limit for CS 2 is 8.65 ppb based on three times the standard deviation of the system noises. The proposed device, which exhibits high sensitivity and effective cost, addresses the urgent demand for the monitoring and diagnosis of SF 6 -insulated electrical equipment via online detection of trace CS 2 . (paper)

  18. Analysis, simulation and control of electromagnetic transients in gas insulated substations in SF6 by means of grounding grid; Analisis, simulacion y control de transitorios electromagneticos en subestaciones aisladas en SF6 por medio de redes de tierra

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Martinez, Gaston

    2007-12-15

    The use of SF6 substations is actually an extensive practice in industrial countries. Some of they replace conventional air substations and the others are new designs in the range of 34.5 kV to 1000 kV. During the switching events in a GIS substation, very fast transients overvoltage may appear and originate faults, malfunctions in the electronic and control equipment, besides the risk by electrical discharge in the personnel who are working in the substation. These overvoltage are produced by the collapse of the electric field on GIS terminals during switching events originating Very Fast Transient Overvoltage (VFTO) and the increase of the Transient Enclosure Voltage (TEV). This investigation is focused on diminishing the magnitude of the VFTO and TEV by designing and redesigning grounding grids for gas insulated substations in SF6. The objective of this work is to design a grounding grid for an air substation and redesign it for a GIS substation. The computer simulation uses a detailed model of the substation in SF6 interconnected with an aerial grounding grid and by adding methodologically grounding rods, the VFTO and TEV within the GIS are reduced. The results of the computer simulation show that the designed grounding grid allows considerably diminishing the magnitude of the VFTO; nevertheless this design doesn't appropriately attenuate the TEV magnitude. [Spanish] Hoy en dia, el uso de subestaciones GIS se ha generalizado. Algunas reemplazan a las subestaciones aereas y otras son de nueva creacion y se instalan en tensiones de 34.5kV hasta 1000 kV. Durante las operaciones de maniobra de la subestacion GIS, se presentan sobretensiones transitorias ultra rapidas que pueden dar origen a diversas fallas, a un malfuncionamiento del equipo electronico y de control asi como el riesgo por descarga electrica al personal que labora en la subestacion. Estas sobretensiones se producen debido al colapso del campo electrico en terminales del interruptor ante

  19. Light-induced lattice expansion leads to high-efficiency perovskite solar cells

    Science.gov (United States)

    Tsai, Hsinhan; Asadpour, Reza; Blancon, Jean-Christophe; Stoumpos, Constantinos C.; Durand, Olivier; Strzalka, Joseph W.; Chen, Bo; Verduzco, Rafael; Ajayan, Pulickel M.; Tretiak, Sergei; Even, Jacky; Alam, Muhammad Ashraf; Kanatzidis, Mercouri G.; Nie, Wanyi; Mohite, Aditya D.

    2018-04-01

    Light-induced structural dynamics plays a vital role in the physical properties, device performance, and stability of hybrid perovskite–based optoelectronic devices. We report that continuous light illumination leads to a uniform lattice expansion in hybrid perovskite thin films, which is critical for obtaining high-efficiency photovoltaic devices. Correlated, in situ structural and device characterizations reveal that light-induced lattice expansion benefits the performances of a mixed-cation pure-halide planar device, boosting the power conversion efficiency from 18.5 to 20.5%. The lattice expansion leads to the relaxation of local lattice strain, which lowers the energetic barriers at the perovskite-contact interfaces, thus improving the open circuit voltage and fill factor. The light-induced lattice expansion did not compromise the stability of these high-efficiency photovoltaic devices under continuous operation at full-spectrum 1-sun (100 milliwatts per square centimeter) illumination for more than 1500 hours.

  20. Understanding the relationship between the EQ-5D, SF-6D, HAQ and disease activity in inflammatory arthritis.

    LENUS (Irish Health Repository)

    Adams, Roisin

    2012-02-01

    BACKGROUND: The growth of economic analyses and in particular cost-utility analyses (CUA), which use the QALY as a measure of outcome, has heightened the interest in the methodologies used to calculate the QALY. The EQ-5D has produced quite different utility values from that of the SF-6D. This article seeks to understand these differences using a cohort of patients with inflammatory arthritis. OBJECTIVE: To examine the relationship between the disease-specific measure, Health Assessment Questionnaire (HAQ) disability index (DI) and the preference-based measures, SF-6D, EQ-5D and European League Against Arthritis (EULAR) Disease Activity Score (DAS) in patients with rheumatoid arthritis (RA) and psoriatic arthritis (PsA). METHODS: Patients with RA and PsA (n = 504) attending a tertiary rheumatology referral centre completed the HAQ, SF-6D and the EQ-5D before starting biological therapy and again 12 months later. The SF-36 was converted into a utility using the preference-based SF-6D. Clinical outcomes such as the DAS, joint counts and laboratory measures were also recorded. We calculated single index utility scores from the preference-based instruments using UK population norms. We used regression analysis to derive a mapping function and calculated utility scores from the HAQDI and the DAS 28. RESULTS: The mean utility observed at baseline for RA was 0.43 for the EQ-5D and 0.54 for the SF-6D and for PsA was 0.49 for the EQ-5D and 0.57 for the SF-6D. The utility gain demonstrated by the EQ-5D was over twice that of the SF-6D. The EQ-5D scored 17% of the RA group as less than 0 (state defined as worse than death); 7% of this group remained less than 0 at follow-up. The distribution of the utility estimates was similar for both RA and PsA. CONCLUSIONS: Our findings draw attention to the impact of states worse than death on the overall distribution for the EQ-5D derived utilities and how these impact on its use in practice. EQ-5D-derived QALY changes are over twice

  1. Electron attachment to the SF{sub 6} molecule

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, B. M., E-mail: bmsmirnov@gmail.com; Kosarim, A. V. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2015-09-15

    Various models for transition between electron and nuclear subsystems are compared in the case of electron attachment to the SF{sub 6} molecule. Experimental data, including the cross section of electron attachment to this molecule as a function of the electron energy and vibrational temperature, the rate constants of this process in swarm experiments, and the rates of the chemionization process involving Rydberg atoms and the SF{sub 6} molecule, are collected and treated. Based on the data and on the resonant character of electron capture into an autodetachment ion state in accordance with the Breit–Wigner formula, we find that intersection of the molecule and negative ion electron terms proceeds above the potential well bottom of the molecule with the barrier height 0.05–0.1 eV, and the transition between these electron terms has both the tunnel and abovebarrier character. The limit of small electron energies e for the electron attachment cross section at room vibrational temperature takes place at ε ≪ 2 meV, while in the range 2 meV ≪ ε ≪ 80 meV, the cross section is inversely proportional to ε. In considering the attachment process as a result of the interaction between the electron and vibrational degrees of freedom, we find the coupling factor f between them to be f = aT at low vibrational temperatures T with a ≈ 3 × 10{sup −4} K{sup −1}. The coupling factor is independent of the temperature at T > 400 K.

  2. Validation and comparison of EuroQoL-5 dimension (EQ-5D) and Short Form-6 dimension (SF-6D) among stable angina patients.

    Science.gov (United States)

    Wu, Jing; Han, Yuerong; Zhao, Fei-Li; Zhou, Jin; Chen, Zhijun; Sun, He

    2014-10-25

    Several preference-based health-related quality of life (HRQoL) instruments have been published and widely used in different populations. However no consensus has emerged regarding the most appropriate instrument in therapeutic area of stable angina. This study compared and validated the psychometric properties of two generic preference-based instruments, the EQ-5D and SF-6D, among Chinese stable angina patients. Convergent validity of the EQ-5D and SF-6D was examined with eight a priori hypotheses from stable angina patients in conjunction with Seattle Angina Questionnaire (SAQ). Responsiveness was compared using the effect size (ES), relative efficiency (RE) and receiver operating characteristic (ROC) curves. Agreement between the EQ-5D and SF-6D was tested using intra-class correlation coefficient (ICC) and Bland-Altman plot. Factors affecting utility difference were explored with multiple linear regression analysis. In 411 patients (mean age 68.08 ± 11.35), mean utility scores (SD) were 0.78 (0.15) for the EQ-5D and 0.68 (0.12) for the SF-6D. Validity was demonstrated by the moderate to strong correlation coefficients (Range: 0.368-0.594, Pstable-angina-specific health status than the EQ-5D (ES: 0.426 to 1.126). RE suggested that the SF-6D (RE: 44.8 to 177.8%) was more efficient than the EQ-5D except for physical function. Poor agreement between them was observed with ICC (0.448, Pstable angina patients. The SF-6D may be a more effective tool with lower ceiling effect and greater sensitivity. Further study is needed to compare other properties, such as reliability and longitudinal response.

  3. Suppressing voltage transients in high voltage power supplies

    International Nuclear Information System (INIS)

    Lickel, K.F.; Stonebank, R.

    1979-01-01

    A high voltage power supply for an X-ray tubes includes voltage adjusting means, a high voltage transformer, switch means connected to make and interrupt the primary current of the transformer, and over-voltage suppression means to suppress the voltage transient produced when the current is switched on. In order to reduce the power losses in the suppression means, an impedance is connected in the transformer primary circuit on operation of the switch means and is subsequently short-circuited by a switch controlled by a timer after a period which is automatically adjusted to the duration of the transient overvoltage. (U.K.)

  4. High-voltage power supply of ND6 portable dose rate meter

    International Nuclear Information System (INIS)

    Wang Shaling

    2001-01-01

    Portable dose rate meter needs to be equipped with a set of high-voltage power supply which is supplied by batteries and has characteristic of high quality, low energy expense and small size. The author introduces application conditions and performance guide line

  5. High Voltage Homemade Capacitor Charger for Plasma Focus System

    International Nuclear Information System (INIS)

    Abdul Halim Baijan; Azaman Ahmad; Rokiah Mohd Sabri; Siti Aiasah Hashim; Mohd Rizal Md Chulan; Wah, L.K.; Azhar Ahmad; Rosli Che Ros; Mohd Faiz Mohd Zin

    2015-01-01

    A high voltage capacitor charger has been designed and built to replace a high voltage charger type General Atomics CCDs Power Supply which was damaged. The fabrication design was using materials which were easily available in the local market. Among the main components of the high-voltage charger is a transformer for neon lights, variable transformer rated 0 - 240 V 1 KVA, and 240 V transformer isolator. The results of experiments that have been conducted shows that a homemade capacitor charger was able to charge high voltage capacitors up to the required voltage of which was 12 kV. However the time taken for charging is quite long, up to more than 6 minutes. (author)

  6. Vivitron 1995, transient voltage simulation, high voltage insulator tests, electric field calculation

    International Nuclear Information System (INIS)

    Frick, G.; Osswald, F.; Heusch, B.

    1996-01-01

    Preliminary investigations showed clearly that, because of the discrete electrode structure of the Vivitron, important overvoltage leading to insulator damage can appear in case of a spark. The first high voltage tests showed damage connected with such events. This fact leads to a severe voltage limitation. This work describes, at first, studies made to understand the effects of transients and the associated over-voltage appearing in the Vivitron. Then we present the high voltage tests made with full size Vivitron components using the CN 6 MV machine as a pilot machine. Extensive field calculations were made. These involve simulations of static stresses and transient overvoltages, on insulating boards and electrodes. This work gave us the solutions for arrangements and modifications in the machine. After application, the Vivitron runs now without any sparks and damage at 20 MV. In the same manner, we tested column insulators of a new design and so we will find out how to get to higher voltages. Electric field calculation around the tie bars connecting the discrete electrodes together showed field enhancements when the voltages applied on the discrete electrodes are not equally distributed. This fact is one of the sources of discharges and voltage limitations. A scenario of a spark event is described and indications are given how to proceed towards higher voltages, in the 30 MV range. (orig.)

  7. Function and horizontal transfer of the small terminase subunit of the tailed bacteriophage Sf6 DNA packaging nanomotor

    Science.gov (United States)

    Leavitt, Justin C.; Gilcrease, Eddie B.; Wilson, Kassandra; Casjens, Sherwood R.

    2013-01-01

    Bacteriophage Sf6 DNA packaging series initiate at many locations across a 2 kbp region. Our in vivo studies that show that Sf6 small terminase subunit (TerS) protein recognizes a specific packaging (pac) site near the center of this region, that this site lies within the portion of the Sf6 gene that encodes the DNA-binding domain of TerS protein, that this domain of the TerS protein is responsible for the imprecision in Sf6 packaging initiation, and that the DNA-binding domain of TerS must be covalently attached to the domain that interacts with the rest of the packaging motor. The TerS DNA-binding domain is self-contained in that it apparently does not interact closely with the rest of the motor and it binds to a recognition site that lies within the DNA that encodes the domain. This arrangement has allowed the horizontal exchange of terS genes among phages to be very successful. PMID:23562538

  8. Particle contamination in gas-insulated systems: new control methods and optimum SF6/N2 mixtures

    International Nuclear Information System (INIS)

    Pace, M.O.; Adcock, J.L.; Christophorou, L.G.

    1984-01-01

    The feasibilities of two new separate techniques to control particle contamination in practical gas-insulated sytems were tested in a small-scale concentric cylinder geometry. In one technique an insulating coating was first formed on the particles in a contaminated system by low-pressure discharges in appropriate gases such as 1-C 3 F 6 and c-C 4 F 8 . When SF 6 was subsequently introduced into the same system at practical pressure as the operating insulation, the considerable harm ordinarily caused by particles was found to be eliminated. The nature of the coating formed also on the electrodes in this process was studied, with the conclusion that the observed benefits were primarily due to coating on particles, not on electrodes. In the second technique the particles, moved randomly by electrical stress, struck and adhered to the surface of a tacky insulating solid material; they were subsequently encapsulated in a melt-resolidify cycle without electrical stress. This trapping technique was also found to eliminate the harmful effects of particles in SF 6 at practical pressure. A technique for producing a trapping material with temperature characteristics appropriate for practical apparatus was devised. The effect of particle contamination on the dielectric strength of SF 6 /N 2 mixtures was studied as a function of total pressure and percentage of each gas. Optimum total pressure (approx. 6 atm) and optimum percentages (60% SF 6 /40% N 2 ) were observed in breakdown tests in particle-contaminated concentric cylinder geometry

  9. The investigation of a compact auto-connected wire-wrapped pulsed transformer.

    Science.gov (United States)

    Wang, Yuwei; Zhang, Jiande; Chen, Dongqun; Cao, Shengguang; Li, Da; Zhang, Tianyang

    2012-05-01

    For the power conditioning circuit used to deliver power efficiently from flux compression generator (FCG) to the load with high impedance, an air-cored and wire-wrapped transformer convenient in coaxial connection to the other parts is investigated. To reduce the size and enhance the performance, an auto-connection is adopted. A fast and simple model is used to calculate the electrical parameters of the transformer. To evaluate the high voltage capability, the voltages across turns and the electric field distribution in the transformer are investigated. The calculated and the measured electrical parameters of the transformer show good agreements. And the safe operating voltage is predicted to exceed 500 kV. In the preliminary experiments, the transformer is tested in a power conditioning circuit with a capacitive power supply. It is demonstrated that the output voltage of the transformer reaches -342 kV under the input voltage of -81 kV.

  10. High voltage test techniques

    CERN Document Server

    Kind, Dieter

    2001-01-01

    The second edition of High Voltage Test Techniques has been completely revised. The present revision takes into account the latest international developments in High Voltage and Measurement technology, making it an essential reference for engineers in the testing field.High Voltage Technology belongs to the traditional area of Electrical Engineering. However, this is not to say that the area has stood still. New insulating materials, computing methods and voltage levels repeatedly pose new problems or open up methods of solution; electromagnetic compatibility (EMC) or components and systems al

  11. Anisotropic etching of silicon for application in micro machine using plasma of SF6/CH4/O2/Ar and SF6/CF4/O2/Ar

    International Nuclear Information System (INIS)

    Reyes B, C.; Moshkalyov, S.A.; Swart, J.W.

    2004-01-01

    We investigated the reactive ion etching of silicon using SF 6 /CH 4 (CF 4 )/O 2 /Ar gas mixtures containing fluorine for MEMS applications. Etch rates and anisotropy of etch profiles were examined as a function of gas composition, material of electrode, and RF power. Etch depths were measured using a profilometers, and etch profiles were analyzed by scanning electron microscope. As a mask material, an aluminium film deposited by evaporation, was used. High anisotropy of etching of 0.95 was achieved at etch depths up to 20-30 micrometers and etch rates of approximately 0.3-0.6 μm/min. Highly anisotropic etching is based on a mechanism that enhance the ion bombarding and protects the sidewalls due to polymerization and/or oxidation mechanisms in order to avoid the lateral etch. However, under the anisotropic etching conditions, considerable damages of the etched surfaces (roughness formation), were observed. After etching experiments, wet / dry cleaning procedures were applied to remove surface residues resulting from the reactive ion etching and to improve the etched surface morphology. (Author)

  12. Substitutes for potent green house gases. HFCs, PFCs and SF{sub 6}. Status report

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, P.H. [Dansk Teknologisk Institut (Denmark)

    1997-12-31

    CFCs (halogenated chlorofluorocarbons), HCFCs (hydrochlorofluorocarbons), HFCs (hydrofluorocarbons), PFCs (fluorocarbons) and SF{sub 6} (sulphur hexafluoride) are all artificial substances which were not to be found in nature until recently. In 1995 the Danish consumption of HFC substances was approximately 740 tonnes, where the corresponding amount of SF{sub 6} was about 17 tonnes. If the entire amount of these substances was released to to the atmosphere, the resulting impact would correspond to an increased emission of greenhouse gases, corresponding to approximately 1.5 million tonnes of CO{sub 2}. HFC substances would account for 73%, SF{sub 6} with 25% and PFC for 1%. This corresponds to approximately 2.6% of the Danish CO{sub 2} emission (nearly 60 million tonnes per year). This corresponds to about half of the aimed 6% reduction of CO{sub 2} emission attained by introduction of mandatory green taxes on CO{sub 2}. According to experience from the CFC programme it is possible to recover some CFC and send it to controlled destruction. From 1993 to 1996 the refrigeration industry, for instance, has returned a total amount of 163 tonnes of CFC refrigerant through the KMO organization (Koelebranchens Miljoe Ordning). Most of this has been destroyed and a small amount has been purified and recycled afterwards. Similarly, it is likely to believe that some HFC refrigerant will be returned through the KMO organization. (au) 11 refs., also published in Danish

  13. Elimination of particle effects in SF/sub 6/ insulated transmission systems. First quarterly report

    Energy Technology Data Exchange (ETDEWEB)

    Dale, S.J.

    1979-01-01

    The purpose of this program is to develop methods and equipment to eliminate the adverse effect of particle contamination in SF/sub 6/-insulated transmission (CGIT) systems, so that the excellent dielectric properties of SF/sub 6/ can be fully exploited. Presently, CGIT systems are operated at about 10% of the dielectric strength capability of the SF/sub 6/ gas. The program includes theoretical and experimental evaluation of concepts, optimization and verification studies in CGIT systems, and reliability analysis, documentation of designs and economic analysis. Progress is now being made on evaluating alternative conductor and sheath designs to minimize the effect of particles. Materials for solid insulation is being investigated for the same purpose; the effort is presently concentrated on obtaining reliable quantitative measurement techniques of electrostatic properties. Computer calculation of particle trap configurations are being made to determine the optimum trap configurations. A novel particle trapping technique is being using adhesive materials. Manufacture and field control technique studies has commenced with a study of mechanical vibration techniques. An experimental test chamber consisting of a 9 m (30 foot) long 145 kV bus has been designed. This system will be used in testing of particle control concepts and in migration and optimization studies.

  14. Development of high voltage PEEK wire with radiation-resistance and cryogenic characteristics

    International Nuclear Information System (INIS)

    Fujita, T.; Hirata, T.; Araki, S.; Ohara, H.; Nishimura, H.

    1989-01-01

    High voltage electric wires insulated with highly-refined polyetheretherketone (PEEK) have been developed for the wiring in fusion reactors, where the wire is required to withstand high voltage under high vacuum up to 10 -5 Torr. The PEEK wires having the advantages of PEEK resin including superior radiation resistance and cryogenic characteristics are usable over a wide range of temperature and in radiation fields. The results of withstand voltage tests proved that the PEEK wires exceeding 0.8 mm in insulation thickness withstand such specified high voltage conditions as 24 kV for 1 minutes by 10 times and 6.6 kV for 110 hours. The results also revealed that the withstand voltage is improved by providing a jacket layer over the insulation and decreased by periodical voltage charge, by bending of the specimen and by water in the conductor. This paper deal with the withstand voltage test results under varied conditions of the PEEK wires. (author)

  15. Reliability of supply of switchgear for auxiliary low voltage in substations extra high voltage to high voltage

    Directory of Open Access Journals (Sweden)

    Perić Dragoslav M.

    2015-01-01

    Full Text Available Switchgear for auxiliary low voltage in substations (SS of extra high voltages (EHV to high voltage (HV - SS EHV/HV kV/kV is of special interest for the functioning of these important SS, as it provides a supply for system of protection and other vital functions of SS. The article addresses several characteristic examples involving MV lines with varying degrees of independence of their supply, and the possible application of direct transformation EHV/LV through special voltage transformers. Auxiliary sources such as inverters and diesel generators, which have limited power and expensive energy, are also used for the supply of switchgear for auxiliary low voltage. Corresponding reliability indices are calculated for all examples including mean expected annual engagement of diesel generators. The applicability of certain solutions of switchgear for auxiliary low voltage SS EHV/HV, taking into account their reliability, feasibility and cost-effectiveness is analyzed too. In particular, the analysis of applications of direct transformation EHV/LV for supply of switchgear for auxiliary low voltage, for both new and existing SS EHV/HV.

  16. Decomposition of SF6-R134a effluents by RF plasma

    International Nuclear Information System (INIS)

    Joshi, Avinash V.

    2012-01-01

    The efficiency of recovery achieved by open or closed loop extraction of RPC exhaust gases is in the range of 90-95% under optimum conditions. For a large detector setup operating on one volume change per day basis, a 5% loss amounts to discharging 50 kg of R134a and 0.5 kg of SF 6 into atmosphere every day. The emissions are equivalent to create nearly 50 000 m 3 of carbon dioxide daily. The gas emissions need to be completely converted to safer compounds. The gases such as R134a and SF 6 are stable compounds. In order to decompose these, the mixture is first activated by adding of 50% oxygen and 2% argon and under typical RF plasma conditions of 13.56 MHz, 1 Torr pressure and 0.2 W/cm 2 power density. The chemical reaction takes place on the surface of a silicon electrode. The product of the reaction is mainly SiF 4 (gas), which is further hydrolyzed to form HF solution and silicon hydroxide sludge. More than 90% of the effluent gas mixture can be effectively removed by this method.

  17. Temporal change of SF6 age in spring during rainstorms in a forested headwater catchment, Fukushima, Japan

    Science.gov (United States)

    Sakakibara, Koichi; Tsujimura, Maki; Onda, Yuichi; Iwagami, Sho; Sato, Yutaro; Nagano, Kosuke

    2017-04-01

    Time variant water age in catchments can fundamentally describe catchment function, controlling rainfall-runoff generation, groundwater flow pathway, and water storage. We observed sulfur hexafluoride concentration in the stream and groundwater with 1 - 2 hours interval during rainstorm events in order to reveal temporal variations of rainfall-runoff water age. Target's spring is perennial in a forested headwater catchment with an area of 0.045 square km, Fukushima, Japan. The observed hydrological data and tracer data of water in the catchment (stable isotopic compositions, inorganic solute concentrations) were used for clarifying rainfall-runoff processes related to water age variances. The storm hydrograph and groundwater table clearly responded to rainfall especially with more than 30 mm per day throughout the monitoring period (May 2015 - October 2016). Large variations of SF6 age in spring ranging from zero to 14 years were found in the short period during rainstorms. In particular, the SF6 age in spring was evidently old when the runoff was over 2 mm per day. At the high runoff condition, the SF6 age in spring positively correlated with discharge rate: the spring age became older as the discharge rate increased. With regard to spatial distributions of SF6 age in groundwater, the old groundwater age (9 - 13 years) in the shallow subsurface area along the valley was confirmed after heavy rainfall. This groundwater age was similar age to the deep groundwater at no-rainfall conditions. In addition, inorganic solute concentrations such as chloride ion, sodium ion, and silica in spring water showed dominant levels in the deep and ridge groundwater. All facts suggest that the old groundwater, stored in the ridge or deeper subsurface area, replaced the shallow groundwater in the vicinity of the spring due to heavy rainfall, then it contributed to the spring discharge. Therefore, rainstorm events play important roles as triggers for discharging older water stored in

  18. The greenhouse gases HFCs, PFCs and SF{sub 6}, Danish consumption and emissions, 2007

    Energy Technology Data Exchange (ETDEWEB)

    Sander Poulsen, T.; Bode, I.

    2009-07-01

    The objective of this project was to determine the Danish consumption and actual emissions of HFCs, PFCs, and SF{sub 6} for 2007. Further, if methodology changes are made in connection to the work on 2007 data, the data for previous years are considered and updated accordingly. The emission calculation is made in accordance with the IPCC guidelines and following the method employed in previous year calculation. The methodology includes calculation of the actual emissions of HFCs, PFCs, and SF{sub 6}. In this calculation of actual emissions, the release from stock of greenhouse gases in products has been taken into account, and adjustments have been made for imports and exports of the greenhouse gases in products. Specific emission factors are presented. (ln)

  19. Rapid and selective expansion of nonclonotypic T cells in regulatory T cell-deficient, foreign antigen-specific TCR-transgenic scurfy mice: antigen-dependent expansion and TCR analysis.

    Science.gov (United States)

    Sharma, Rahul; Ju, Angela Chiao-Ying; Kung, John T; Fu, Shu Man; Ju, Shyr-Te

    2008-11-15

    Foreign Ag-specific TCR-transgenic (Tg) mice contain a small fraction of T cells bearing the endogenous Vbeta and Valpha chains as well as a population expressing an intermediate level of Tg TCR. Importantly, these minor nonclonotypic populations contain > or = 99% of the CD4(+)Foxp3(+) regulatory T cells (Treg) and, despite low overall Treg expression, peripheral tolerance is maintained. In the OT-II TCR (OVA-specific, Vbeta5(high)Valpha2(high)) Tg scurfy (Sf) mice (OT-II Sf) that lack Treg, nonclonotypic T cells markedly expanded in the periphery but not in the thymus. Expanded T cells expressed memory/effector phenotype and were enriched in blood and inflamed lungs. In contrast, Vbeta5(high)Valpha2(high) clonotypic T cells were not expanded, displayed the naive phenotype, and found mainly in the lymph nodes. Importantly, Vbeta5(neg) T cells were able to transfer multiorgan inflammation in Rag1(-/-) recipients. T cells bearing dual TCR (dual Vbeta or dual Valpha) were demonstrated frequently in the Vbeta5(int) and Valpha2(int) populations. Our study demonstrated that in the absence of Treg, the lack of peripheral expansion of clonotypic T cells is due to the absence of its high-affinity Ag OVA. Thus, the rapid expansion of nonclonotypic T cells in OT-II Sf mice must require Ag (self and foreign) with sufficient affinity. Our study has implications with respect to the roles of Ag and dual TCR in the selection and regulation of Treg and Treg-controlled Ag-dependent T cell expansion in TCR Tg and TCR Tg Sf mice, respectively.

  20. A high-voltage equipment (high voltage supply, high voltage pulse generators, resonant charging inductance, synchro-instruments for gyrotron frequency measurements) for plasma applications

    International Nuclear Information System (INIS)

    Spassov, Velin

    1996-01-01

    This document reports my activities as visitor-professor at the Gyrotron Project - INPE Plasma Laboratory. The main objective of my activities was designing, construction and testing a suitable high-voltage pulse generator for plasma applications, and efforts were concentrated on the following points: Design of high-voltage resonant power supply with tunable output (0 - 50 kV) for line-type high voltage pulse generator; design of line-type pulse generator (4 microseconds pulse duration, 0 - 25 kV tunable voltage) for non linear loads such as a gyrotron and P III reactor; design of resonant charging inductance for resonant line-type pulse generator, and design of high resolution synchro instrument for gyrotron frequency measurement. (author)

  1. The Design and Characterization of a Prototype Wideband Voltage Sensor Based on a Resistive Divider.

    Science.gov (United States)

    Garnacho, Fernando; Khamlichi, Abderrahim; Rovira, Jorge

    2017-11-17

    The most important advantage of voltage dividers over traditional voltage transformers is that voltage dividers do not have an iron core with non-linear hysteresis characteristics. The voltage dividers have a linear behavior with respect to over-voltages and a flat frequency response larger frequency range. The weak point of a voltage divider is the influence of external high-voltage (HV) and earth parts in its vicinity. Electrical fields arising from high voltages in neighboring phases and from ground conductors and structures are one of their main sources for systematic measurement errors. This paper describes a shielding voltage divider for a 24 kV medium voltage network insulated in SF6 composed of two resistive-capacitive dividers, one integrated within the other, achieving a flat frequency response up to 10 kHz for ratio error and up to 5 kHz for phase displacement error. The metal shielding improves its immunity against electric and magnetic fields. The characterization performed on the built-in voltage sensor shows an accuracy class of 0.2 for a frequency range from 20 Hz to 5 kHz and a class of 0.5 for 1 Hz up to 20 Hz. A low temperature effect is also achieved for operation conditions of MV power grids.

  2. Inactivation of Tm6sf2, a Gene Defective in Fatty Liver Disease, Impairs Lipidation but Not Secretion of Very Low Density Lipoproteins.

    Science.gov (United States)

    Smagris, Eriks; Gilyard, Shenise; BasuRay, Soumik; Cohen, Jonathan C; Hobbs, Helen H

    2016-05-13

    A missense mutation (E167K) in TM6SF2 (transmembrane 6 superfamily member 2), a polytopic protein of unknown function, is associated with the full spectrum of fatty liver disease. To investigate the role of TM6SF2 in hepatic triglyceride (TG) metabolism, we inactivated the gene in mice. Chronic inactivation of Tm6sf2 in mice is associated with hepatic steatosis, hypocholesterolemia, and transaminitis, thus recapitulating the phenotype observed in humans. No dietary challenge was required to elicit the phenotype. Immunocytochemical and cell fractionation studies revealed that TM6SF2 was present in the endoplasmic reticulum and Golgi complex, whereas the excess neutral lipids in the Tm6sf2(-/-) mice were located in lipid droplets. Plasma VLDL-TG levels were reduced in the KO animals due to a 3-fold decrease in VLDL-TG secretion rate without any associated reduction in hepatic apoB secretion. Both VLDL particle size and plasma cholesterol levels were significantly reduced in KO mice. Despite levels of TM6SF2 protein being 10-fold higher in the small intestine than in the liver, dietary lipid absorption was only modestly reduced in the KO mice. Our data, taken together, reveal that TM6SF2 is required to mobilize neutral lipids for VLDL assembly but is not required for secretion of apoB-containing lipoproteins. Despite TM6SF2 being located in the endoplasmic reticulum and Golgi complex, the lipids that accumulate in its absence reside in lipid droplets. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  3. Thermal re-ignition processes of switching arcs with various gas-blast using voltage application highly controlled by powersemiconductors

    Science.gov (United States)

    Nakano, Tomoyuki; Tanaka, Yasunori; Murai, K.; Uesugi, Y.; Ishijima, T.; Tomita, K.; Suzuki, K.; Shinkai, T.

    2018-05-01

    This paper focuses on a fundamental experimental approach to thermal arc re-ignition processes in a variety of gas flows in a nozzle. Using power semiconductor switches in the experimental system, the arc current and the voltage applied to the arc were controlled with precise timing. With this system, residual arcs were created in decaying phase under free recovery conditions; arc re-ignition was then intentionally instigated by application of artificial voltage—i.e. quasi-transient recovery voltage—to study the arc behaviour in both decaying and re-ignition phases. In this study, SF6, CO2, N2, O2, air and Ar arcs were intentionally re-ignited by quasi-TRV application at 20 μs delay time from initiation of free recovery condition. Through these experiments, the electron density at the nozzle throat was measured using a laser Thomson scattering method together with high speed video camera observation during the re-ignition process. Temporal variations in the electron density from the arc decaying to re-ignition phases were successfully obtained for each gas-blast arc at the nozzle throat. In addition, initial dielectric recovery properties of SF6, CO2, air and Ar arcs were measured under the same conditions. These data will be useful in the fundamental elucidation of thermal arc re-ignition processes.

  4. A global model for SF6 plasmas coupling reaction kinetics in the gas phase and on the surface of the reactor walls

    International Nuclear Information System (INIS)

    Kokkoris, George; Panagiotopoulos, Apostolos; Gogolides, Evangelos; Goodyear, Andy; Cooke, Mike

    2009-01-01

    Gas phase and reactor wall-surface kinetics are coupled in a global model for SF 6 plasmas. A complete set of gas phase and surface reactions is formulated. The rate coefficients of the electron impact reactions are based on pertinent cross section data from the literature, which are integrated over a Druyvesteyn electron energy distribution function. The rate coefficients of the surface reactions are adjustable parameters and are calculated by fitting the model to experimental data from an inductively coupled plasma reactor, i.e. F atom density and pressure change after the ignition of the discharge. The model predicts that SF 6 , F, F 2 and SF 4 are the dominant neutral species while SF 5 + and F - are the dominant ions. The fit sheds light on the interaction between the gas phase and the reactor walls. A loss mechanism for SF x radicals by deposition of a fluoro-sulfur film on the reactor walls is needed to predict the experimental data. It is found that there is a net production of SF 5 , F 2 and SF 6 , and a net consumption of F, SF 3 and SF 4 on the reactor walls. Surface reactions as well as reactions between neutral species in the gas phase are found to be important sources and sinks of the neutral species.

  5. Adsorption behaviour of SF6 decomposed species onto Pd4-decorated single-walled CNT: a DFT study

    Science.gov (United States)

    Cui, Hao; Zhang, Xiaoxing; Zhang, Jun; Tang, Ju

    2018-07-01

    Metal nanocluster decorated single-walled carbon nanotubes (SWCNT) with improved adsorption behaviour towards gaseous molecules compared with intrinsic ones, have been widely accepted as a workable media for gas interaction due to their strong catalysis. In this work, Pd4 cluster is determined as a catalytic centre to theoretically study the adsorption property of Pd4-decorated SWCNT upon SF6 decomposed species. Results indicate that Pd4-SWCNT possessing good responses and sensitivities towards three composed species of SF6 could realise selective detection for them according to the different conductivity changes resulting from the varying adsorption ability. The response of Pd4-SWCNT upon three molecules in order is SOF2 > H2S > SO2, and the conductivity of the proposed material is about to increase in SOF2 and H2S systems, while declining in SO2 system. Such conclusions would be helpful for experimentalists to explore novel SWCNT-based sensors in evaluating the operating state of SF6 insulation devices.

  6. High-voltage, high-current, solid-state closing switch

    Science.gov (United States)

    Focia, Ronald Jeffrey

    2017-08-22

    A high-voltage, high-current, solid-state closing switch uses a field-effect transistor (e.g., a MOSFET) to trigger a high-voltage stack of thyristors. The switch can have a high hold-off voltage, high current carrying capacity, and high time-rate-of-change of current, di/dt. The fast closing switch can be used in pulsed power applications.

  7. Validation and comparison of EuroQoL-5 dimension (EQ-5D) and Short Form-6 dimension (SF-6D) among stable angina patients

    OpenAIRE

    Wu, Jing; Han, Yuerong; Zhao, Fei-Li; Zhou, Jin; Chen, Zhijun; Sun, He

    2014-01-01

    Objectives Several preference-based health-related quality of life (HRQoL) instruments have been published and widely used in different populations. However no consensus has emerged regarding the most appropriate instrument in therapeutic area of stable angina. This study compared and validated the psychometric properties of two generic preference-based instruments, the EQ-5D and SF-6D, among Chinese stable angina patients. Methods Convergent validity of the EQ-5D and SF-6D was examined with ...

  8. Design and fabrication of resonator-quantum well infrared photodetector for SF6 gas sensor application

    Science.gov (United States)

    Sun, Jason; Choi, Kwong-Kit; DeCuir, Eric; Olver, Kimberley; Fu, Richard

    2017-07-01

    The infrared absorption of SF6 gas is narrowband and peaks at 10.6 μm. This narrowband absorption posts a stringent requirement on the corresponding sensors as they need to collect enough signal from this limited spectral bandwidth to maintain a high sensitivity. Resonator-quantum well infrared photodetectors (R-QWIPs) are the next generation of QWIP detectors that use resonances to increase the quantum efficiency for more efficient signal collection. Since the resonant approach is applicable to narrowband as well as broadband, it is particularly suitable for this application. We designed and fabricated R-QWIPs for SF6 gas detection. To achieve the expected performance, the detector geometry must be produced according to precise specifications. In particular, the height of the diffractive elements and the thickness of the active resonator must be uniform, and accurately realized to within 0.05 μm. Additionally, the substrates of the detectors must be completely removed to prevent the escape of unabsorbed light in the detectors. To achieve these specifications, two optimized inductively coupled plasma etching processes were developed. Due to submicron detector feature sizes and overlay tolerance, we used an advanced semiconductor material lithography stepper instead of a contact mask aligner to pattern wafers. Using these etching techniques and tool, we have fabricated focal plane arrays with 30-μm pixel pitch and 320×256 format. The initial test revealed promising results.

  9. Gas transport below artificial recharge ponds: insights from dissolved noble gases and a dual gas (SF6 and 3He) tracer experiment.

    Science.gov (United States)

    Clark, Jordan F; Hudson, G Bryant; Avisar, Dror

    2005-06-01

    A dual gas tracer experiment using sulfur hexafluoride (SF6) and an isotope of helium (3He) and measurements of dissolved noble gases was performed at the El Rio spreading grounds to examine gas transport and trapped air below an artificial recharge pond with a very high recharge rate (approximately 4 m day(-1)). Noble gas concentrations in the groundwater were greater than in surface water due to excess air formation showing that trapped air exists below the pond. Breakthrough curves of SF6 and 3He at two nearby production wells were very similar and suggest that nonequilibrium gas transfer was occurring between the percolating water and the trapped air. At one well screened between 50 and 90 m below ground, both tracers were detected after 5 days and reached a maximum at approximately 24 days. Despite the potential dilution caused by mixing within the production well, the maximum concentration was approximately 25% of the mean pond concentration. More than 50% of the SF6 recharged was recovered by the production wells during the 18 month long experiment. Our results demonstrate that at artificial recharge sites with high infiltration rates and moderately deep water tables, transport times between recharge locations and wells determined with gas tracer experiments are reliable.

  10. 48 CFR 53.301-18 - SF 18 (Rev. 6/95), Request for Quotations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false SF 18 (Rev. 6/95), Request for Quotations. 53.301-18 Section 53.301-18 Federal Acquisition Regulations System FEDERAL ACQUISITION... for Quotations. EC01MY91.002 [60 FR 34763, July 3, 1995] ...

  11. High voltage research (breakdown strengths of gaseous and liquid insulators). Semiannual report, April 1--September 30, 1977

    Energy Technology Data Exchange (ETDEWEB)

    Christophorou, L. G.; James, D. R.; Pai, R. Y.; Mathis, R. A.; Pace, M. O.; Bouldin, D. W.; Christodoulides, A. A.; Chan, C. C.

    1977-11-01

    Direct current breakdown strength measurements on a large number of multicomponent gas mixtures at low (approximately less than 1 atm) and high (approximately less than 5 atm) pressures led to the discovery of many gas mixtures of electron-attaching gases and strongly electron-attaching gases with N/sub 2/ and C/sub 3/F/sub 8/ which are superior to SF/sub 6/. Of special significance are mixtures containing C/sub 4/F/sub 6/ (perfluoro-2-butyne). The breakdown strength of one such mixture (20 percent C/sub 4/F/sub 6/ to 80 percent SF/sub 6/) is approximately 30 percent higher than pure SF/sub 6/ under identical conditions, both at low (approximately 0.7 atm) and high (4.6 atm) pressures. Perfluorocyclohexene (C/sub 6/F/sub 10/) and C/sub 5/F/sub 8/ (perfluorocyclopentene) were found at low pressure (approximately 0.2 atm) to be, respectively, approximately 2.1 and 2.2 times better than SF/sub 6/ under comparable conditions; they both have a potential as additives in gas mixtures. The effect of the inelastic electron scattering properties of a gas via negative ion resonances in the low-energy range (1 to approximately 4 eV) on the breakdown strength has been demonstrated for H/sub 2/, N/sub 2/, and CO and binary mixtures of these with SF/sub 6/ and C/sub 4/F/sub 6/ (perfluoro-2-butyne). The construction of a new high pressure (to approximately 11 atm), variable temperature (-50/sup 0/C to + 150/sup 0/C) apparatus has been completed and a practical test facility utilizing cylindrical electrode geometries has been put into operation; the first results on the latter apparatus were on SF/sub 6/-N/sub 2/ and c-C/sub 4/F/sub 8/--N/sub 2/ mixtures. Studies of environmental effects of dielectric gases via their electron-impact-induced decompositions and analysis of their breakdown products have begun using mass spectrometry and gas chromatography; C/sub 4/F/sub 6/ (perfluoro-2-butyne) seems to be resistant to electron-impact-induced decomposition indicating long

  12. Genome-wide identification of SF1 and SF2 helicases from archaea.

    Science.gov (United States)

    Chamieh, Hala; Ibrahim, Hiba; Kozah, Juliana

    2016-01-15

    Archaea microorganisms have long been used as model organisms for the study of protein molecular machines. Archaeal proteins are particularly appealing to study since archaea, even though prokaryotic, possess eukaryotic-like cellular processes. Super Family I (SF1) and Super Family II (SF2) helicase families have been studied in many model organisms, little is known about their presence and distribution in archaea. We performed an exhaustive search of homologs of SF1 and SF2 helicase proteins in 95 complete archaeal genomes. In the present study, we identified the complete sets of SF1 and SF2 helicases in archaea. Comparative analysis between archaea, human and the bacteria E. coli SF1 and SF2 helicases, resulted in the identification of seven helicase families conserved among representatives of the domains of life. This analysis suggests that these helicase families are highly conserved throughout evolution. We highlight the conserved motifs of each family and characteristic domains of the detected families. Distribution of SF1/SF2 families show that Ski2-like, Lhr, Sfth and Rad3-like helicases are ubiquitous among archaeal genomes while the other families are specific to certain archaeal groups. We also report the presence of a novel SF2 helicase specific to archaea domain named Archaea Specific Helicase (ASH). Phylogenetic analysis indicated that ASH has evolved in Euryarchaeota and is evolutionary related to the Ski2-like family with specific characteristic domains. Our study provides the first exhaustive analysis of SF1 and SF2 helicases from archaea. It expands the variety of SF1 and SF2 archaeal helicases known to exist to date and provides a starting point for new biochemical and genetic studies needed to validate their biological functions. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. CMOS-compatible high-voltage integrated circuits

    Energy Technology Data Exchange (ETDEWEB)

    Parpia, Z

    1988-01-01

    Considerable savings in cost and development time can be achieved if high-voltage ICs (HVICs) are fabricated in an existing low-voltage process. In this thesis, the feasibility of fabricating HVICs in a standard CMOS process is investigated. The high-voltage capabilities of an existing 5-{mu}m CMOS process are first studied. High-voltage n- and p-channel transistors with breakdown voltages of 50 and 190 V, respectively, were fabricated without any modifications to the process under consideration. SPICE models for these transistors are developed, and their accuracy verified by comparison with experimental results. In addition, the effect of the interconnect metallization on the high-voltage performance of these devices is also examined. Polysilicon field plates are found to be effective in preventing premature interconnect induced breakdown in these devices. A novel high-voltage transistor structure, the insulated base transistor (IBT), based on a merged MOS-bipolar concept, is proposed and implemented. In order to enhance the high-voltage device capabilities, an improved CMOS-compatible HVIC process using junction isolation is developed.

  14. High voltage research (breakdown strengths of gaseous and liquid insulators). Semiannual report, October 1, 1977--March 31, 1978

    International Nuclear Information System (INIS)

    Christophorou, L.G.; James, D.R.; Pai, R.Y.; Mathis, R.A.; Sauers, I.; Pace, M.O.; Bouldin, D.W.; Christodoulides, A.A.; Chan, C.C.

    1978-06-01

    The work on gas mixtures is focused on combinations of gases consisting of strongly electron-attaching components and one or more electron slowing-down components. Hypotheses based on the positions of electronically excited states are borne out experimentally in the low pressure ( 6 . Although the ionization cross section for Ar is very much greater than that for Ne, Ar is a superior buffer gas. A theoretical discussion is given which describes the relation between the dielectric strength of a gas to its physical parameters including the electron attachment cross section, the ionization cross section, the ionization potential, and the electron energy distribution function. Also discussed is the importance of perfluorination in hydrocarbons to effect an increase in the electron attachment cross section and electron affinity and a decrease in the ionization cross section, and hence an increase in dielectric strength. Attachment rates were measured as a function of the mean electron energy for a comprehensive list of perfluorocarbons. Breakdown voltages were determined for SF 6 and for SF 6 (20%)/N 2 (80%) as a function of temperature from -15 0 C to 85 0 C. Environmental aspects of gas dielectrics pertaining to gas decomposition and toxicity were studied

  15. Temporary over voltages in the high voltage networks

    International Nuclear Information System (INIS)

    Vukelja, Petar; Naumov, Radomir; Mrvic, Jovan; Minovski, Risto

    2001-01-01

    The paper treats the temporary over voltages that may arise in the high voltage networks as a result of: ground faults, loss of load, loss of one or two phases and switching operation. Based on the analysis, the measures for their limitation are proposed. (Original)

  16. Deep Learning Algorithm for Auto-Delineation of High-Risk Oropharyngeal Clinical Target Volumes With Built-In Dice Similarity Coefficient Parameter Optimization Function.

    Science.gov (United States)

    Cardenas, Carlos E; McCarroll, Rachel E; Court, Laurence E; Elgohari, Baher A; Elhalawani, Hesham; Fuller, Clifton D; Kamal, Mona J; Meheissen, Mohamed A M; Mohamed, Abdallah S R; Rao, Arvind; Williams, Bowman; Wong, Andrew; Yang, Jinzhong; Aristophanous, Michalis

    2018-06-01

    Automating and standardizing the contouring of clinical target volumes (CTVs) can reduce interphysician variability, which is one of the largest sources of uncertainty in head and neck radiation therapy. In addition to using uniform margin expansions to auto-delineate high-risk CTVs, very little work has been performed to provide patient- and disease-specific high-risk CTVs. The aim of the present study was to develop a deep neural network for the auto-delineation of high-risk CTVs. Fifty-two oropharyngeal cancer patients were selected for the present study. All patients were treated at The University of Texas MD Anderson Cancer Center from January 2006 to August 2010 and had previously contoured gross tumor volumes and CTVs. We developed a deep learning algorithm using deep auto-encoders to identify physician contouring patterns at our institution. These models use distance map information from surrounding anatomic structures and the gross tumor volume as input parameters and conduct voxel-based classification to identify voxels that are part of the high-risk CTV. In addition, we developed a novel probability threshold selection function, based on the Dice similarity coefficient (DSC), to improve the generalization of the predicted volumes. The DSC-based function is implemented during an inner cross-validation loop, and probability thresholds are selected a priori during model parameter optimization. We performed a volumetric comparison between the predicted and manually contoured volumes to assess our model. The predicted volumes had a median DSC value of 0.81 (range 0.62-0.90), median mean surface distance of 2.8 mm (range 1.6-5.5), and median 95th Hausdorff distance of 7.5 mm (range 4.7-17.9) when comparing our predicted high-risk CTVs with the physician manual contours. These predicted high-risk CTVs provided close agreement to the ground-truth compared with current interobserver variability. The predicted contours could be implemented clinically, with only

  17. Application of high voltage electric field (HVEF) drying technology in potato chips

    International Nuclear Information System (INIS)

    Bai, Yaxiang; Shi, Hua; Yang, Yaxin

    2013-01-01

    In order to improve the drying efficiency and qualities of vegetable by high voltage electric field (HVEF), potato chips as a representative of vegetable was dried using a high voltage electric drying systems at 20°C. The shrinkage rate, water absorption and rehydration ratio of dried potato chips were measured. The results indicated that the drying rate of potato chips was significantly improved in the high voltage electric drying systems. The shrinkage rate of potato chips dried by high voltage electric field was 1.1% lower than that by oven drying method. And the rehydration rate of high voltage electric field was 24.6% higher than that by oven drying method. High voltage electric field drying is very advantageous and can be used as a substitute for traditional drying method.

  18. The modelling of an SF6 arc in a supersonic nozzle: II. Current zero behaviour of the nozzle arc

    International Nuclear Information System (INIS)

    Zhang, Q; Liu, J; Yan, J D; Fang, M T C

    2016-01-01

    The present work (part II) forms the second part of an investigation into the behaviour of SF 6 nozzle arc. It is concerned with the aerodynamic and electrical behaviour of a transient nozzle arc under a current ramp specified by a rate of current decay (d i /d t ) before current zero and a voltage ramp (d V /d t ) after current zero. The five flow models used in part I [1] for cold gas flow and DC nozzle arcs have been applied to study the transient arc at three stagnation pressures ( P 0 ) and two values of d i /d t for the current ramp, representing a wide range of arcing conditions. An analysis of the physical mechanisms encompassed in each flow model is given with an emphasis on the adequacy of a particular model in describing the rapidly varying arc around current zero. The critical rate of rise of recovery voltage (RRRV) is found computationally and compared with test results of Benenson et al [2]. For transient nozzle arcs, the RRRV is proportional to the square of P 0 , rather than to the square root of P 0 for DC nozzle arcs. The physical mechanisms responsible for the strong dependence of RRRV on P 0 have been investigated. The relative merits of the flow models employed are discussed. (paper)

  19. Co-intercalation of Mg(2+) and Na(+) in Na(0.69)Fe2(CN)6 as a High-Voltage Cathode for Magnesium Batteries.

    Science.gov (United States)

    Kim, Dong-Min; Kim, Youngjin; Arumugam, Durairaj; Woo, Sang Won; Jo, Yong Nam; Park, Min-Sik; Kim, Young-Jun; Choi, Nam-Soon; Lee, Kyu Tae

    2016-04-06

    Thanks to the advantages of low cost and good safety, magnesium metal batteries get the limelight as substituent for lithium ion batteries. However, the energy density of state-of-the-art magnesium batteries is not high enough because of their low operating potential; thus, it is necessary to improve the energy density by developing new high-voltage cathode materials. In this study, nanosized Berlin green Fe2(CN)6 and Prussian blue Na(0.69)Fe2(CN)6 are compared as high-voltage cathode materials for magnesium batteries. Interestingly, while Mg(2+) ions cannot be intercalated in Fe2(CN)6, Na(0.69)Fe2(CN)6 shows reversible intercalation and deintercalation of Mg(2+) ions, although they have the same crystal structure except for the presence of Na(+) ions. This phenomenon is attributed to the fact that Mg(2+) ions are more stable in Na(+)-containing Na(0.69)Fe2(CN)6 than in Na(+)-free Fe2(CN)6, indicating Na(+) ions in Na(0.69)Fe2(CN)6 plays a crucial role in stabilizing Mg(2+) ions. Na(0.69)Fe2(CN)6 delivers reversible capacity of approximately 70 mA h g(-1) at 3.0 V vs Mg/Mg(2+) and shows stable cycle performance over 35 cycles. Therefore, Prussian blue analogues are promising structures for high-voltage cathode materials in Mg batteries. Furthermore, this co-intercalation effect suggests new avenues for the development of cathode materials in hybrid magnesium batteries that use both Mg(2+) and Na(+) ions as charge carriers.

  20. Transient voltage sharing in series-coupled high voltage switches

    Directory of Open Access Journals (Sweden)

    Editorial Office

    1992-07-01

    Full Text Available For switching voltages in excess of the maximum blocking voltage of a switching element (for example, thyristor, MOSFET or bipolar transistor such elements are often coupled in series - and additional circuitry has to be provided to ensure equal voltage sharing. Between each such series element and system ground there is a certain parasitic capacitance that may draw a significant current during high-speed voltage transients. The "open" switch is modelled as a ladder network. Analy­sis reveals an exponential progression in the distribution of the applied voltage across the elements. Overstressing thus oc­curs in some of the elements at levels of the total voltage that are significantly below the design value. This difficulty is overcome by grading the voltage sharing circuitry, coupled in parallel with each element, in a prescribed manner, as set out here.

  1. Assessment of Eco-friendly Gases for Electrical Insulation to Replace the Most Potent Industrial Greenhouse Gas SF6.

    Science.gov (United States)

    Rabie, Mohamed; Franck, Christian M

    2018-01-16

    Gases for electrical insulation are essential for the operation of electric power equipment. This Review gives a brief history of gaseous insulation that involved the emergence of the most potent industrial greenhouse gas known today, namely sulfur hexafluoride. SF 6 paved the way to space-saving equipment for the transmission and distribution of electrical energy. Its ever-rising usage in the electrical grid also played a decisive role in the continuous increase of atmospheric SF 6 abundance over the last decades. This Review broadly covers the environmental concerns related to SF 6 emissions and assesses the latest generation of eco-friendly replacement gases. They offer great potential for reducing greenhouse gas emissions from electrical equipment but at the same time involve technical trade-offs. The rumors of one or the other being superior seem premature, in particular because of the lack of dielectric, environmental, and chemical information for these relatively novel compounds and their dissociation products during operation.

  2. Complications among colorectal cancer survivors: SF-6D preference-weighted quality of life scores.

    Science.gov (United States)

    Hornbrook, Mark C; Wendel, Christopher S; Coons, Stephen Joel; Grant, Marcia; Herrinton, Lisa J; Mohler, M Jane; Baldwin, Carol M; McMullen, Carmit K; Green, Sylvan B; Altschuler, Andrea; Rawl, Susan M; Krouse, Robert S

    2011-03-01

    Societal preference-weighted health-related quality of life (HRQOL) scores enable comparing multidimensional health states across diseases and treatments for research and policy. To assess the effects of living with a permanent intestinal stoma, compared with a major bowel resection, among colorectal cancer (CRC) survivors. Cross-sectional multivariate linear regression analysis to explain preference-weighted HRQOL scores. In all, 640 CRC survivors (≥ 5 years) from 3 group model health maintenance organizations; ostomates and nonostomates with colorectal resections for CRC were matched on gender, age (± 5 years), time since diagnosis, and tumor site (rectum vs. colon). SF-6D scoring system was applied to Medical Outcomes Study Short Form-36 version 2 (SF-36v2); City of Hope Quality of Life-Ostomy; and Charlson-Deyo comorbidity index. Survey of CRC survivors linked to respondents' clinical data extracted from health maintenance organization files. Response rate was 52%. Ostomates and nonostomates had similar sociodemographic characteristics. Mean SF-6D score was 0.69 for ostomates, compared with 0.73 for nonostomates (P ostomy after other factors were taken into account. Surgical complications, comorbidities, and metastatic disease lowered the preference-weighted HRQOL of CRC survivors with and without ostomies. Further research to understand and reduce late complications from CRC surgeries as well as associated depression is warranted.

  3. Investigating Characteristics of N2, CO2 and CF3I in Contrast to High Current Arcs in Circuit Breakers to Choose a Suitable Substitute for SF6

    Directory of Open Access Journals (Sweden)

    V. Abbasi

    2017-09-01

    Full Text Available Specific and sensitive operation of circuit breakers makes an individual position for them in power networks. Circuit breakers are at the central gravity of variations and execution operations. Therefore, an optimum operation is the main reason to investigate about new gases to be used in MV and HV circuit breakers instead of SF6. The arc process has enormous complexity because of hydrodynamic and electromagnetic combination equations, and that is the exact reason why most of the previous simulations were processed in two-dimension analysis. But, in this paper a three-dimension simulation with sufficient results has been fully discussed. Different evaluations on the other gases have taken under study in order to find a suitable substitute instead of SF6 gas, which can also bring an optimum operation for the breakers and can be even friendly with the environment. The simulations have been carried out based on the finite element method (FEM and magneto-hydrodynamic equations. A three-dimension model under the transient state has been chosen in the simulations to find a feasible substitute for SF6 gas. The main factors of the analysis are threefold as follows: arc temperature on the different regions, the cooling ability and arc resistance. CO2, CF3I and N2 are nominated to substitute the SF6 gas and their effects on cooling ability, nozzle evaporation, contacts erosion and arc resistance will be discussed.

  4. Bipolar High-Voltage, Long-Duration Pulsed Radiofrequency Improves Pain Relief in Postherpetic Neuralgia.

    Science.gov (United States)

    Wan, Cheng-Fu; Liu, Yan; Dong, Dao-Song; Zhao, Lin; Xi, Qi; Yu, Xue; Cui, Wen-Yao; Wang, Qiu-Shi; Song, Tao

    2016-07-01

    Postherpetic neuralgia (PHN) is often refractory to existing treatments. Treatment of the dorsal root ganglion (DRG) using monopolar pulsed radiofrequency (PRF), which is a non- or minimally neurodestructive technique, is not efficacious in all patients. This study aimed to determine the safety and clinical efficacy of bipolar high-voltage, long-duration PRF on the DRG in PHN patients. Self before-after controlled clinical trial. Department of Pain Medicine, the First Affiliated Hospital of China Medical University. Ninety patients diagnosed with PHN for > 3months were included. Bipolar high-voltage, long-duration PRF at 42°C for 900 seconds was applied after the induction of paresthesias covered the regions of hyperalgesic skin. The therapeutic effects were evaluated using a visual analog scale (VAS) and the 36-item Short Form health survey (SF-36) before treatment and one, 4, 8, and 12 weeks after PRF. The VAS scores at one, 4, 8, and 12 weeks after PRF treatment were significantly lower than before treatment (P DRG is an effective and safe therapeutic alternative for PHN patients. This treatment could improve the quality of life of PHN patients. NO ChiCTR-OCS-14005461.

  5. Computer applications: Automatic control system for high-voltage accelerator

    International Nuclear Information System (INIS)

    Bryukhanov, A.N.; Komissarov, P.Yu.; Lapin, V.V.; Latushkin, S.T.. Fomenko, D.E.; Yudin, L.I.

    1992-01-01

    An automatic control system for a high-voltage electrostatic accelerator with an accelerating potential of up to 500 kV is described. The electronic apparatus on the high-voltage platform is controlled and monitored by means of a fiber-optic data-exchange system. The system is based on CAMAC modules that are controlled by a microprocessor crate controller. Data on accelerator operation are represented and control instructions are issued by means of an alphanumeric terminal. 8 refs., 6 figs

  6. Mathematical model of three winding auto transformer

    International Nuclear Information System (INIS)

    Volcko, V.; Eleschova, Z.; Belan, A.; Janiga, P.

    2012-01-01

    This article deals with the design of mathematical model of three-winding auto transformer for steady state analyses. The article is focused on model simplicity for the purposes of the use in complex transmission systems and authenticity of the model taking into account different types of step-voltage regulator. (Authors)

  7. High voltage research (breakdown strengths of gaseous and liquid insulators). Semiannual report, October 1, 1977--March 31, 1978. [Summaries of research activities at Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Christophorou, L.G.; James, D.R.; Pai, R.Y.; Mathis, R.A.; Sauers, I.; Pace, M.O.; Bouldin, D.W.; Christodoulides, A.A.; Chan, C.C.

    1978-06-01

    The work on gas mixtures is focused on combinations of gases consisting of strongly electron-attaching components and one or more electron slowing-down components. Hypotheses based on the positions of electronically excited states are borne out experimentally in the low pressure (<1000 torr) breakdown measurements. The high pressure work shows dramatically the importance of the electron scattering cross section on breakdown strength by comparing Ar with Ne as single gases and in mixtures with SF/sub 6/. Although the ionization cross section for Ar is very much greater than that for Ne, Ar is a superior buffer gas. A theoretical discussion is given which describes the relation between the dielectric strength of a gas to its physical parameters including the electron attachment cross section, the ionization cross section, the ionization potential, and the electron energy distribution function. Also discussed is the importance of perfluorination in hydrocarbons to effect an increase in the electron attachment cross section and electron affinity and a decrease in the ionization cross section, and hence an increase in dielectric strength. Attachment rates were measured as a function of the mean electron energy for a comprehensive list of perfluorocarbons. Breakdown voltages were determined for SF/sub 6/ and for SF/sub 6/ (20%)/N/sub 2/(80%) as a function of temperature from -15/sup 0/C to 85/sup 0/C. Environmental aspects of gas dielectrics pertaining to gas decomposition and toxicity were studied.

  8. LED-Based High-Voltage Lines Warning System

    Directory of Open Access Journals (Sweden)

    Eldar MUSA

    2013-04-01

    Full Text Available LED-based system, running with the current of high-voltage lines and converting the current flowing through the line into the light by using a toroid transformer, has been developed. The transformer’s primary winding is constituted by the high voltage power line. Toroidal core consists of two equal parts and the secondary windings are evenly placed on these two parts. The system is mounted on the high-voltage lines as a clamp. The secondary winding ends are connected in series by the connector on the clamp. LEDs are supplied by the voltage at the ends of secondary. Current flowing through highvoltage transmission lines is converted to voltage by the toroidal transformer and the light emitting LEDs are supplied with this voltage. The theory of the conversion of the current flowing through the line into the light is given. The system, running with the current of the line and converting the current into the light, has been developed. System has many application areas such as warning high voltage lines (warning winches to not hinder the high-voltage lines when working under the lines, warning planes to not touch the high-voltage lines, remote measurement of high-voltage line currents, and local illumination of the line area

  9. Optimum injection and combustion for gaseous fuel engine : characteristics of hydrogen auto-ignition phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, T.; Mikami, S.; Senda, J.; Fujimoto, H. [Doshisha Univ. (Japan). Dept. of Mechanical Engineering; Nakatani, K. [Fuji Heavy Industries Ltd. (Japan); Tokunaga, Y. [Kawasaki Heavy Industries Ltd. (Japan)

    2002-07-01

    A study was conducted in which the auto-ignition characteristics of hydrogen were examined in order to determine which factors dominate auto-ignition delay of hydrogen jets. Experiments were performed in a rapid compression/expansion machine in order to study the effects of ambient gas density and oxygen concentration on the auto-ignition delays. The focus of research was on an inert gas circulation type cogeneration system to apply hydrogen to a medium-sized diesel engine. Freedom of fuel-oxidizer mixing, ignition and combustion in the system could be achieved for stable combustion, high thermal efficiency, and zero emission. The study also involved chemical analysis using a detailed hydrogen reaction model that could simulate auto-ignition delays under various temperature, pressures, equivalence ratio, and dilution. It is shown that auto-ignition delays of hydrogen jets are very dependent on the ambient gas temperature and less dependent on its density and oxygen concentration. Temperature and hydrogen concentrations have significant impacts on the production and consumption rates of H{sub 2}O{sub 2} and OH radicals. 21 refs., 1 tab., 10 figs.

  10. 76 FR 70721 - Voltage Coordination on High Voltage Grids; Notice of Staff Workshop

    Science.gov (United States)

    2011-11-15

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD12-5-000] Voltage Coordination on High Voltage Grids; Notice of Staff Workshop Take notice that the Federal Energy Regulatory Commission will hold a Workshop on Voltage Coordination on High Voltage Grids on Thursday, December 1, 2011...

  11. Accelerator System Development at High Voltage Engineering

    International Nuclear Information System (INIS)

    Klein, M. G.; Gottdang, A.; Haitsma, R. G.; Mous, D. J. W.

    2009-01-01

    Throughout the years, HVE has continuously extended the capabilities of its accelerator systems to meet the rising demands from a diverse field of applications, among which are deep level ion implantation, micro-machining, neutron production for biomedical research, isotope production or accelerator mass spectrometry. Characteristic for HVE accelerators is the coaxial construction of the all solid state power supply around the acceleration tubes. With the use of solid state technology, the accelerators feature high stability and very low ripple. Terminal voltages range from 1 to 6 MV for HVE Singletrons and Tandetrons. The high-current versions of these accelerators can provide ion beams with powers of several kW. In the last years, several systems have been built with terminal voltages of 1.25 MV, 2 MV and 5 MV. Recently, the first system based on a 6 MV Tandetron has passed the factory tests. In this paper we describe the characteristics of the HVE accelerator systems and present as example recent systems.

  12. Multigroup Approximation of Radiation Transfer in SF6 Arc Plasmas

    Directory of Open Access Journals (Sweden)

    Milada Bartlova

    2013-01-01

    Full Text Available The first order of the method of spherical harmonics (P1-approximation has been used to evaluate the radiation properties of arc plasmas of various mixtures of SF6 and PTFE ((C2F4n, polytetrafluoroethylene in the temperature range (1000 ÷ 35 000 K and pressures from 0.5 to 5 MPa. Calculations have been performed for isothermal cylindrical plasma of various radii (0.01 ÷ 10 cm. The frequency dependence of the absorption coefficients has been handled using the Planck and Rosseland averaging methods for several frequency intervals. Results obtained using various means calculated for different choices of frequency intervals are discussed.

  13. Compact high voltage, high peak power, high frequency transformer for converter type modulator applications.

    Science.gov (United States)

    Reghu, T; Mandloi, V; Shrivastava, Purushottam

    2016-04-01

    The design and development of a compact high voltage, high peak power, high frequency transformer for a converter type modulator of klystron amplifiers is presented. The transformer has been designed to operate at a frequency of 20 kHz and at a flux swing of ±0.6 T. Iron (Fe) based nanocrystalline material has been selected as a core for the construction of the transformer. The transformer employs a specially designed solid Teflon bobbin having 120 kV insulation for winding the high voltage secondary windings. The flux swing of the core has been experimentally found by plotting the hysteresis loop at actual operating conditions. Based on the design, a prototype transformer has been built which is per se a unique combination of high voltage, high frequency, and peak power specifications. The transformer was able to provide 58 kV (pk-pk) at the secondary with a peak power handling capability of 700 kVA. The transformation ratio was 1:17. The performance of the transformer is also presented and discussed.

  14. System for high-voltage control detectors with large number photomultipliers

    International Nuclear Information System (INIS)

    Donskov, S.V.; Kachanov, V.A.; Mikhajlov, Yu.V.

    1985-01-01

    A simple and inexpensive on-line system for hihg-voltage control which is designed for detectors with a large number of photomultipliers is developed and manufactured. It has been developed for the GAMC type hodoscopic electromagnetic calorimeters, comprising up to 4 thousand photomultipliers. High voltage variation is performed by a high-speed potentiometer which is rotated by a microengine. Block-diagrams of computer control electronics are presented. The high-voltage control system has been used for five years in the IHEP and CERN accelerator experiments. The operation experience has shown that it is quite simple and convenient in operation. In case of about 6 thousand controlled channels in both experiments no potentiometer and microengines failures were observed

  15. Refurbishment and retrofitting of SF6 gas storage tanks of the pelletron accelerator

    International Nuclear Information System (INIS)

    Reddy, G.R.; Datar, V.M.; Parulekar, Y.M.

    2015-01-01

    The BARC-TIFR Pelletron Accelerator Facility has completed more than twenty six years of successful round-the-clock operation, serving diverse users from institutions within and outside DAE. The main accelerating structure and associated subsystems are housed in the accelerator tank under SF 6 gas medium. During maintenance of the accelerator, the SF 6 gas present in the accelerator tank is transferred in the four storage tanks located on the terrace of the building open to outside environment. These four storage tanks (with ∼ 1/4th of the main tank volume each) are ∼ 4.27 m in diameter and ∼ 10 m in height each and are supported on RCC ring beams which are monolithically connected with the RCC structure below. Over the years, the anchor bolts and the base plates of support structure of storage tanks were found corroded and the foundation RCC ring beam indicated a few corrosion cracks. Health assessment of relevant structures and components were carried out. Considering the limitations of existing anchorage and also giving due considerations for reparability and replaceability, a new anchorage system was designed. The entire refurbishment and retrofitting works pertaining to the four SF 6 gas storage tanks was executed in a time bound manner to comply with the then PASC (Particle Accelerator Safety Committee) recommendations successfully, without disrupting the operations of the round-the-clock running Pelletron Accelerator facility. In addition, the thickness measurements for the storage tanks were performed. The relief valves and rupture disc assemblies across the storage tanks were replaced and reinstalled after introducing appropriate manual valves as suggested by the PASC. A new test set up was fabricated to perform pneumatic testing at the recommended pressure off-line for these relief valves and rupture disc assemblies prior to reinstallation. This paper describes the comprehensive rehabilitation and retrofitting procedures that were carried out at the

  16. On-site voltage measurement with capacitive sensors on high voltage systems

    NARCIS (Netherlands)

    Wu, L.; Wouters, P.A.A.F.; Heesch, van E.J.M.; Steennis, E.F.

    2011-01-01

    In Extra/High-Voltage (EHV/HV) power systems, over-voltages occur e.g. due to transients or resonances. At places where no conventional voltage measurement devices can be installed, on-site measurement of these occurrences requires preferably non intrusive sensors, which can be installed with little

  17. Mechanical strength and hydrophobicity of cotton fabric after SF6 plasma treatment

    Science.gov (United States)

    Kamlangkla, K.; Paosawatyanyong, B.; Pavarajarn, V.; Hodak, Jose H.; Hodak, Satreerat K.

    2010-08-01

    Surface treatments to tailor fabric properties are in high demand by the modern garment industry. We studied the effect of radio-frequency inductively coupled SF plasma on the surface characteristics of cotton fabric. The duration of the treatment and the SF pressure were varied systematically. We measured the hydrophobicity of treated cotton as a function of storage time and washing cycles. We used the weight loss (%) along with the etching rate, the tensile strength, the morphology changes and the hydrophobicity of the fabric as observables after treatments with different plasma conditions. The weight loss remains below 1% but it significantly increases when the treatment time is longer than 5 min. Substantial changes in the surface morphology of the fiber are concomitant with the increased etching rate and increased weight loss with measurable consequences in their mechanical characteristics. The measured water absorption time reaches the maximum of 210 min when the SF pressure is higher than 0.3 Torr. The water contact angle ( 149°) and the absorption time (210 min) of cotton treated with extreme conditions appear to be durable as long as the fabric is not washed. X-ray photoelectron spectroscopy analysis reveals that the water absorption time of the fabric follows the same increasing trend as the fluorine/carbon ratio at the fabric surface and atom density of fluorine measured by Ar actinometer.

  18. 41 CFR 304-6.5 - What guidelines must we follow when using the Standard Form (SF) 326?

    Science.gov (United States)

    2010-07-01

    ... REQUIREMENTS 6-PAYMENT GUIDELINES Reports § 304-6.5 What guidelines must we follow when using the Standard Form... 41 Public Contracts and Property Management 4 2010-07-01 2010-07-01 false What guidelines must we follow when using the Standard Form (SF) 326? 304-6.5 Section 304-6.5 Public Contracts and Property...

  19. Ionization smoke detectors - the high-voltage issues

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Production of high-voltage ionization smoke detectors ceased in 1978 following the development of lower voltage models which used much smaller amounts of radioactive material. Despite this fact, thousands of high-voltage detectors are still in use today in many large UK companies. The major users argue that there is no reason to stop using their detectors if they are still fit for their purpose - many could last for another 15 to 20 years if properly maintained. But pressure has been mounting on businesses to replace all their high-voltage detectors with new low-voltage models within the next couple of years. This could place a huge financial burden on the companies concerned, with costs possibly running into millions of pounds. Traditionally, the major detector installers offered cleaning and maintenance services for high-voltage detectors to their customers but these have now been withdrawn. The installers give no clear reasons for this decision except that the detectors are outmoded and should be disposed of as soon as possible. Most users would agree that conversion to low-voltage types is inevitable but their main worry is the financial strain of replacing all their detectors - and associated equipment - in one go. They would prefer to phase out their high-voltage detectors in stages over a number of years to spread the costs of conversion. The problems of maintenance is discussed. A dual voltage fire alarm panel which allows the high-voltage detectors to be phased out is mentioned. (Author)

  20. High-frequency high-voltage high-power DC-to-DC converters

    Science.gov (United States)

    Wilson, T. G.; Owen, H. A.; Wilson, P. M.

    1982-09-01

    A simple analysis of the current and voltage waveshapes associated with the power transistor and the power diode in an example current-or-voltage step-up (buck-boost) converter is presented. The purpose of the analysis is to provide an overview of the problems and design trade-offs which must be addressed as high-power high-voltage converters are operated at switching frequencies in the range of 100 kHz and beyond. Although the analysis focuses on the current-or-voltage step-up converter as the vehicle for discussion, the basic principles presented are applicable to other converter topologies as well.

  1. High voltage engineering fundamentals

    CERN Document Server

    Kuffel, E; Hammond, P

    1984-01-01

    Provides a comprehensive treatment of high voltage engineering fundamentals at the introductory and intermediate levels. It covers: techniques used for generation and measurement of high direct, alternating and surge voltages for general application in industrial testing and selected special examples found in basic research; analytical and numerical calculation of electrostatic fields in simple practical insulation system; basic ionisation and decay processes in gases and breakdown mechanisms of gaseous, liquid and solid dielectrics; partial discharges and modern discharge detectors; and over

  2. A Head-to-Head Comparison of UK SF-6D and Thai and UK EQ-5D-5L Value Sets in Thai Patients with Chronic Diseases.

    Science.gov (United States)

    Sakthong, Phantipa; Munpan, Wipaporn

    2017-10-01

    Little was known about the head-to-head comparison of psychometric properties between SF-6D and EQ-5D-5L or the different value sets of EQ-5D-5L. Therefore, this study set out to compare the psychometric properties including agreement, convergent, and known-group validity between the SF-6D and the EQ-5D-5L using the real value sets from Thailand and the UK in patients with chronic diseases. 356 adults taking a medication for at least 3 months were identified from a university hospital in Bangkok, Thailand, between July 2014 and March 2015. Agreement was assessed by intraclass correlation coefficients (ICCs) and Bland-Altman plots. Convergent validity was evaluated using Spearman's rank correlation coefficients between SF-6D and EQ-5D-5L and EQ-VAS and SF-12v2. For known-groups validity, the Mann-Whitney U test and Kruskal-Wallis test were used to examine the associations between SF-6D and EQ-5D-5L and patient characteristics. Agreements between the SF-6D and the EQ-5D-5L using Thai and UK value sets were fair, with ICCs of 0.45 and 0.49, respectively. Bland-Altman plots showed that the majority of the SF-6D index scores were lower than the EQ-5D-5L index scores. Both the EQ-5D-5L value sets were more related to the EQ-VAS and physical health, while the SF-6D was more associated with mental health. Both EQ-5D-5L value sets were more sensitive than the SF-6D in discriminating patients with different levels of more known groups except for adverse drug reactions. The SF-6D and both EQ-5D-5L value sets appeared to be valid but sensitive to different outcomes in Thai patients with chronic diseases.

  3. The multielectron character of the S 2p → 4e{sub g} shape resonance in the SF{sub 6} molecule studied via detection of soft X-ray emission and neutral high-Rydberg fragments

    Energy Technology Data Exchange (ETDEWEB)

    Kivimäki, A., E-mail: kivimaki@iom.cnr.it [CNR—Istituto Officina dei Materiali (IOM), Laboratorio TASC, 34149 Trieste (Italy); Coreno, M. [CNR—Istituto di Struttura della Materia (ISM), Basovizza Area Science Park, 34149 Trieste (Italy); Miotti, P.; Frassetto, F.; Poletto, L. [CNR—Istituto di Fotonica e Nanotecnologie (IFN), via Trasea 7, 35131 Padova (Italy); Stråhlman, C. [MAX IV Laboratory, Lund University, P.O. Box 118, 22100 Lund (Sweden); Simone, M. de [CNR—Istituto Officina dei Materiali (IOM), Laboratorio TASC, 34149 Trieste (Italy); Richter, R. [Elettra-Sincrotrone Trieste, Area Science Park Basovizza, 34149 Trieste (Italy)

    2016-05-15

    Highlights: • The soft X-ray emission spectrum of SF{sub 6} changes at the S 2p → 4e{sub g} shape resonance. • The emission band around 172 eV indicates the population of the 6a{sub 1g} orbital. • Shake-up processes accompanying S 2p ionization can explain the new emissions. • Field ionization of neutral high Rydberg (HR) fragments reveals F and S atoms. • The yield of neutral HR fragments increases at the S 2p → 4e{sub g} shape resonance. - Abstract: We have studied the nature of the S 2p → 4e{sub g} shape resonance in the SF{sub 6} molecule by performing two different experiments. Soft X-ray emission spectra measured at the 4e{sub g} shape resonance reveal features that do not originate from the S 2p{sup −1} states. One of the features can be assigned to the 6a{sub 1g} → S 2p transition. The 6a{sub 1g} orbital, which is empty in the molecular ground state, can be populated either in core–valence double excitations or in S 2p shake-up transitions. Both these channels are considered. We have also studied the fragmentation of SF{sub 6} molecule after the decay of the S 2p core-hole states by observing neutral fragments in high-Rydberg states, where an electron occupies an orbital with n ≥ 20 (n is the principal quantum number). Such neutral fragments become, in relative terms, more abundant at the S 2p → 4e{sub g} shape resonance with respect to the S 2p → 2t{sub 2g} shape resonance, which is a pure one-electron phenomenon.

  4. 30 CFR 75.804 - Underground high-voltage cables.

    Science.gov (United States)

    2010-07-01

    ... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.804 Underground high-voltage cables. (a) Underground high-voltage cables used in resistance... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground high-voltage cables. 75.804 Section...

  5. Ozone depleting substances and greenhouse gases HFCs, PFCs and SF{sub 6} consumption and emissions; Ozonlagsnedbrydende stoffer og drivhusgasserne HFC'er, PFC'er og SF{sub 6}. Forbrug og emissioner 2002

    Energy Technology Data Exchange (ETDEWEB)

    Sander Poulsen, T. [Planmiljoe, Veksoe Sjaelland (Denmark)

    2004-07-01

    The aim of the project is to map the 2002 Danish consumption of produced ozone depleting substances and the consumption and actual emission of the greenhouse gases HFCs, PFCs and SF{sub 6}. The inventory is performed, partly according to the guidelines recommended by IPCC (Intergovernmental Panel on Climate Change), and partly according to the method that has been used for previous mappings. The mapping is done partly in order to meet Denmark's international commitments to report and partly in order to monitor how the consumption of ozone depleting substances and the emissions of greenhouse gases develop. The mapping of ozone depleting substances includes the net consumption, meaning the amount of the imported raw materials in bulk or in drums minus any re-export of the substances in the form of raw materials. Mapping of the actual emissions of HFCs, PFCs and SF{sub 6} is done in continuation of previous greenhouse gas inventories. The inventory process is continuously improving due to development of international approved guidelines (IPCC) and the production of increasingly detailed data. (BA)

  6. Series asymmetric supercapacitors based on free-standing inner-connection electrodes for high energy density and high output voltage

    Science.gov (United States)

    Tao, Jiayou; Liu, Nishuang; Rao, Jiangyu; Ding, Longwei; Al Bahrani, Majid Raissan; Li, Luying; Su, Jun; Gao, Yihua

    2014-11-01

    Asymmetric supercapacitors (ASCs) based on free-standing membranes with high energy density and high output voltage are reported. MnO2 nanowire/carbon nanotube (CNT) composites and MoO3 nanobelt/CNT composites are selected as the anode and the cathode materials of the devices, respectively. The ASC has a high volumetric capacitance of 50.2 F cm-3 at a scan rate of 2 mV s-1 and a high operation voltage window of 2.0 V. Especially, after a middle layer with an inner-connection structure was inserted between the anode and the cathode, the output voltage of the whole device can achieve 4.0 V. The full cell of series ASCs (SASC) with an inner-connection middle layer has a high energy density of 28.6 mW h cm-3 at a power density of 261.4 mW cm-3, and exhibits excellent cycling performance of 99.6% capacitance retention over 10 000 cycles. This strategy of designing the hybridized structure for SASCs provides a promising route for next-generation SCs with high energy density and high output voltage.Asymmetric supercapacitors (ASCs) based on free-standing membranes with high energy density and high output voltage are reported. MnO2 nanowire/carbon nanotube (CNT) composites and MoO3 nanobelt/CNT composites are selected as the anode and the cathode materials of the devices, respectively. The ASC has a high volumetric capacitance of 50.2 F cm-3 at a scan rate of 2 mV s-1 and a high operation voltage window of 2.0 V. Especially, after a middle layer with an inner-connection structure was inserted between the anode and the cathode, the output voltage of the whole device can achieve 4.0 V. The full cell of series ASCs (SASC) with an inner-connection middle layer has a high energy density of 28.6 mW h cm-3 at a power density of 261.4 mW cm-3, and exhibits excellent cycling performance of 99.6% capacitance retention over 10 000 cycles. This strategy of designing the hybridized structure for SASCs provides a promising route for next-generation SCs with high energy density and high

  7. High-voltage engineering and testing

    CERN Document Server

    Ryan, Hugh M

    2013-01-01

    This 3rd edition of High Voltage Engineering Testing describes strategic developments in the field and reflects on how they can best be managed. All the key components of high voltage and distribution systems are covered including electric power networks, UHV and HV. Distribution systems including HVDC and power electronic systems are also considered.

  8. Modular high voltage power supply for chemical analysis

    Science.gov (United States)

    Stamps, James F [Livermore, CA; Yee, Daniel D [Dublin, CA

    2008-07-15

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  9. High density plasma via hole etching in SiC

    International Nuclear Information System (INIS)

    Cho, H.; Lee, K.P.; Leerungnawarat, P.; Chu, S.N.G.; Ren, F.; Pearton, S.J.; Zetterling, C.-M.

    2001-01-01

    Throughwafer vias up to 100 μm deep were formed in 4H-SiC substrates by inductively coupled plasma etching with SF 6 /O 2 at a controlled rate of ∼0.6 μm min-1 and use of Al masks. Selectivities of >50 for SiC over Al were achieved. Electrical (capacitance-voltage: current-voltage) and chemical (Auger electron spectroscopy) analysis techniques showed that the etching produced only minor changes in reverse breakdown voltage, Schottky barrier height, and near surface stoichiometry of the SiC and had high selectivity over common frontside metallization. The SiC etch rate was a strong function of the incident ion energy during plasma exposure. This process is attractive for power SiC transistors intended for high current, high temperature applications and also for SiC micromachining

  10. Influence of the meteorological parameters on CFCs and SF6 concentration in the air of Krakow, Poland

    Science.gov (United States)

    Bielewski, Jarosław; Najman, Joanna; Śliwka, Ireneusz; Bartyzel, Jakub; Rosiek, Janusz

    2013-04-01

    key words: gas chromatography, trace gases, CFCs and SF6 measurements in urban area. Halogenated compounds (chlorofluorocarbons-CFCs), both natural and industrial, so-called freons, currently exist as trace gases in the entire human environment. The CFCs cause ozone depletion in the stratosphere. Moreover CFCs and SF6 take part in intensification of the greenhouse effect. The decisions of the Vienna Convention (1985) and of the Montreal Protocol (1987) limited the world production level of CFCs in the year 1989 at least 35% after 2004, 90% after 2015 and total reduction after year 2030. On account of international agreements, the measurements of CFCs and SF6 in air were started. Measurement "clean" stations were situated at places outside of urban areas influence and gathered on world program - AGAGE (Advanced Global Atmospheric Gases Experiment). One of these stations is Mace Head (Ireland, 53o N, 10o W), which participates in AGAGE since 1987 [1] and in European InGOS (Integrated non-CO2 Greenhouse gas Observing System) program since 2011. Similar research is also conducted in Central Europe, in urban area of Krakow (Poland, 50o N, 19o E) since 1997. The work discusses results from 15 years of concentration measurements (in the years 1997-2012) of selected halocarbons and SF6 in Krakow. To obtain concentrations of measured compounds the mathematical procedure has been used, where concentrations were calculated using a five points Lagrange's interpolation method. Using temporary measurement data were determined daily arithmetic means and their standard deviations. Based on these data, efficiency of Montreal Protocol legislation, implemented in Poland (The Journal of Laws No. 52) could be assessed [2]. Additionally cut-off filtration method was used to estimate trend of the base line of individual air pollutant. Rejected exceedances of base lines were corelated with meteorological characteristics of Krakow region to evaluate possible sources of pollution. The

  11. High voltage designing of 300.000 Volt

    International Nuclear Information System (INIS)

    Hutapea, Sumihar.

    1978-01-01

    Some methods of designing a.c and d.c high voltage supplies are discussed. A high voltage supply for the Gama Research Centre accelerator is designed using transistor pulse generators. High voltage transformers being made using radio transistor ferrits as a core are also discussed. (author)

  12. Assessment of Factors Related to Auto-PEEP.

    Science.gov (United States)

    Natalini, Giuseppe; Tuzzo, Daniele; Rosano, Antonio; Testa, Marco; Grazioli, Michele; Pennestrì, Vincenzo; Amodeo, Guido; Marsilia, Paolo F; Tinnirello, Andrea; Berruto, Francesco; Fiorillo, Marialinda; Filippini, Matteo; Peratoner, Alberto; Minelli, Cosetta; Bernardini, Achille

    2016-02-01

    Previous physiological studies have identified factors that are involved in auto-PEEP generation. In our study, we examined how much auto-PEEP is generated from factors that are involved in its development. One hundred eighty-six subjects undergoing controlled mechanical ventilation with persistent expiratory flow at the beginning of each inspiration were enrolled in the study. Volume-controlled continuous mandatory ventilation with PEEP of 0 cm H2O was applied while maintaining the ventilator setting as chosen by the attending physician. End-expiratory and end-inspiratory airway occlusion maneuvers were performed to calculate respiratory mechanics, and tidal flow limitation was assessed by a maneuver of manual compression of the abdomen. The variable with the strongest effect on auto-PEEP was flow limitation, which was associated with an increase of 2.4 cm H2O in auto-PEEP values. Moreover, auto-PEEP values were directly related to resistance of the respiratory system and body mass index and inversely related to expiratory time/time constant. Variables that were associated with the breathing pattern (tidal volume, frequency minute ventilation, and expiratory time) did not show any relationship with auto-PEEP values. The risk of auto-PEEP ≥5 cm H2O was increased by flow limitation (adjusted odds ratio 17; 95% CI: 6-56.2), expiratory time/time constant ratio 15 cm H2O/L s (3; 1.3-6.9), age >65 y (2.8; 1.2-6.5), and body mass index >26 kg/m(2) (2.6; 1.1-6.1). Flow limitation, expiratory time/time constant, resistance of the respiratory system, and obesity are the most important variables that affect auto-PEEP values. Frequency expiratory time, tidal volume, and minute ventilation were not independently associated with auto-PEEP. Therapeutic strategies aimed at reducing auto-PEEP and its adverse effects should be primarily oriented to the variables that mainly affect auto-PEEP values. Copyright © 2016 by Daedalus Enterprises.

  13. The thermal expansion of a highly crystalline hexagonal BC2N compound synthesized under high temperature and pressure

    International Nuclear Information System (INIS)

    Wu Qinghua; Liu Zhongyuan; Hu Qianku; Li Hui; He Julong; Yu Dongli; Li Dongchun; Tian Yongjun

    2006-01-01

    The thermal expansion has been investigated for a highly crystalline hexagonal BC 2 N compound synthesized by the compression of a turbostratic B-C-N precursor with iron catalyst at the high temperature of 1500 deg. C and the high pressure of 5.5 GPa. The thermal expansion in the c direction is large and linear with an expansion coefficient of 35.86 x 10 -6 K -1 up to 1000 deg. C, while in the basal plane, the a dimension displays a slight linear contraction up to 750 deg. C with a contraction coefficient of -8.76 x 10 -7 K -1 , but above 750 deg. C a linear expansion is observed with a larger expansion coefficient of 1.52 x 10 -6 K -1

  14. 30 CFR 75.813 - High-voltage longwalls; scope.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage longwalls; scope. 75.813 Section... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution High-Voltage Longwalls § 75.813 High-voltage longwalls; scope. Sections 75.814 through 75.822 of this...

  15. The host outer membrane proteins OmpA and OmpC are associated with the Shigella phage Sf6 virion

    International Nuclear Information System (INIS)

    Zhao Haiyan; Sequeira, Reuben D.; Galeva, Nadezhda A.; Tang Liang

    2011-01-01

    Assembly of dsDNA bacteriophage is a precisely programmed process. Potential roles of host cell components in phage assembly haven't been well understood. It was previously reported that two unidentified proteins were present in bacteriophage Sf6 virion (Casjens et al, 2004, J.Mol.Biol. 339, 379-394, Fig. 2A). Using tandem mass spectrometry, we have identified the two proteins as outer membrane proteins (OMPs) OmpA and OmpC from its host Shigella flexneri. The transmission electron cryo-microscopy structure of Sf6 shows significant density at specific sites at the phage capsid inner surface. This density fit well with the characteristic beta-barrel domains of OMPs, thus may be due to the two host proteins. Locations of this density suggest a role in Sf6 morphogenesis reminiscent of phage-encoded cementing proteins. These data indicate a new, OMP-related phage:host linkage, adding to previous knowledge that some lambdoid bacteriophage genomes contain OmpC-like genes that express phage-encoded porins in the lysogenic state.

  16. 6th International Symposium on Thermal Expansion

    CERN Document Server

    1978-01-01

    This 6th International Symposium on Thermal Expansion, the first outside the USA, was held on August 29-31, 1977 at the Gull Harbour Resort on Hecla Island, Manitoba, Canada. Symposium Chairman was Ian D. Peggs, Atomic Energy of Canada Limited, and our continuing sponsor was CINDAS/Purdue University. We made considerable efforts to broaden the base this year to include more users of expansion data but with little success. We were successful, however, in establishing a session on liquids, an area which is receiving more attention as a logical extension to the high-speed thermophysical property measurements on materials at temperatures close to their melting points. The Symposium had good international representation but the overall attendance was, disappointingly, relatively low. Neverthe­ less, this enhanced the informal atmosphere throughout the meeting with a resultant frank exchange of information and ideas which all attendees appreciated. A totally new item this year was the presentation of a bursary to ...

  17. Development of an amorphous surge blocker for a high voltage acceleration power supply of the neutral beam injectors

    International Nuclear Information System (INIS)

    Mizuno, Makoto; Ohara, Yoshihiro; Watanabe, Kazuhiro; Ozaki, Akira.

    1993-10-01

    An amorphous surge blocker for a high voltage acceleration power supply for the neutral beam injectors has been developed. Since the saturation magnetic flux density of the amorphous core is higher than that of the ferrite core, the surge blocker made of amorphous cores can be reduced in size appreciably compared to the conventional ferrite surge blocker. A 350 kV, 0.05 volt-second amorphous surge blocker was designed, fabricated and tested. The amorphous core was made by winding an amorphous tape with a film for the layer insulation and was heat-treated to recover the magnetic characteristics. The core is molded by epoxy resin and installed in a FRP insulator tube filled with SF 6 gas for the insulation. The volt-second measured was higher than the designed value and the electrical breakdown along the cores and between layers was not observed. This test result shows that the amorphous surge blocker is applicable for a dc acceleration power supply for high energy neutral beam injectors. (author)

  18. Age dating and flow path evaluation of groundwater by SF6 and microbe in the foot of Mt. Fuji, central Japan

    Science.gov (United States)

    Yamamoto, Chisato; Tsujimura, Maki; Kato, Kenji; Nagaosa, Kazuyo; Sakakibara, Koichi; Umei, Yohei; Ohara, Kazuma

    2016-04-01

    A variety of industries are developed at the foot of volcanic mountains in Japan and the groundwater is major source for industrial activity in those regions. The age of groundwater has been estimated to be from 10 to 30 years in Mt. Fuji regions by using 36Cl and 3H. However, the age has not been evaluated using SF6 with higher time resolution in these regions. Also, the total number of prokaryotes shows a specific value in each spring water, suggesting different path and age of the groundwater. Therefore, we aim to estimate residence time and the groundwater flow in three dimensions using the multi-tracers approach; CFCs, SF6, the total number of prokaryotes, the stable isotopes of oxygen-18, deuterium. We collected totally 25 spring water samples in Mt. Fuji and analyzed concentration of inorganic ions, the stable isotopes of oxygen-18, deuterium, CFCs, SF6. The apparent age of the spring water was estimated to be ranging from 4 to 19 years at the foot of Mt. Fuji. These results are reasonable as considering the existed age data by36Cl (Tosaki, 2008) in this region. The spring water with younger age tends to show higher total number of prokaryotes, suggesting that the groundwater flows dominantly through the shallow and young lava with the higher total number of prokaryotes, leads to younger age. Focusing on a specific spring water, the seasonal change of SF6 and total number of prokaryotes were monitored. The spring water showed a younger age and higher total number of prokaryotes during the high water flow season, whereas it showed an older age and lower total number of prokaryotes. Therefore, the total number of prokaryotes shows a good negative correlation with the residence time of the spring/ groundwater in space and time. This shows a possibility that the total number of prokaryotes could be a useful tracer of groundwater for time and space in the three dimensions information.

  19. High-voltage pulsed life of multistressed polypropylene capacitor dielectric

    International Nuclear Information System (INIS)

    Laghari, J.R.

    1992-01-01

    High-voltage polypropylene capacitors were aged under singular as well as simultaneous multiple stresses (electrical, thermal, and radiation) at the University of Buffalo's 2 MW thermal nuclear reactor. These stresses were combined neutron-gamma radiation with a total dose of 1.6 x 10 6 rad, electrical stress at 40 V rms /μm, and thermal stress at 90 degrees C. After exposure, the polypropylene dielectric was tested for life (number of pulses to fail) under high-voltage high-repetition-rate (100 pps) pulses. Pulsed life data were also compared with ac life data. Results show that radiation stress causes the most degradation in life, either acting alone or in combination with other stresses. The largest reduction in life occurs when polypropylene is aged under simultaneous multiple stresses (electrical, thermal, and radiation). In this paper, it is shown that pulsed life can be equivalently compared with ac life

  20. Absolute elastic cross sections for electron scattering from SF6

    International Nuclear Information System (INIS)

    Gulley, R.J.; Uhlmann, L.J.; Dedman, C.J.; Buckman, S.J.; Cho, H.; Trantham, K.W.

    2000-01-01

    Full text: Absolute differential cross sections for vibrationally elastic scattering of electrons from sulphur hexafluoride (SF 6 ) have been measured at fixed angles of 60 deg, 90 deg and 120 deg over the energy range of 5 to 15 eV, and also at 11 fixed energies between 2.7 and 75 eV for scattering angles between 10 deg and 180 deg. These measurements employ the magnetic angle-changing technique of Read and Channing in combination with the relative flow technique to obtain absolute elastic scattering cross sections at backward angles (135 deg to 180 deg) for incident energies below 15 eV. The results reveal some substantial differences with several previous determinations and a reasonably good level of agreement with a recent close coupling calculation

  1. Effect of Fibroblast Growth Factor 2 on Equine Synovial Fluid Chondroprogenitor Expansion and Chondrogenesis

    Directory of Open Access Journals (Sweden)

    Marta Bianchessi

    2016-01-01

    Full Text Available Mesenchymal stem cells have been identified in the synovial fluid of several species. This study was conducted to characterize chondroprogenitor (CP cells in equine synovial fluid (SF and to determine the effect of fibroblast growth factor 2 (FGF-2 on SF-CP monolayer proliferation and subsequent chondrogenesis. We hypothesized that FGF-2 would stimulate SF-CP proliferation and postexpansion chondrogenesis. SF aspirates were collected from adult equine joints. Colony-forming unit (CFU assays were performed during primary cultures. At first passage, SF-cells were seeded at low density, with or without FGF-2. Following monolayer expansion and serial immunophenotyping, cells were transferred to chondrogenic pellet cultures. Pellets were analyzed for chondrogenic mRNA expression and cartilage matrix secretion. There was a mean of 59.2 CFU/mL of SF. FGF-2 increased the number of population doublings during two monolayer passages and halved the population doubling times. FGF-2 did not alter the immunophenotype of SF-CPs during monolayer expansion, nor did FGF-2 compromise chondrogenesis. Hypertrophic phenotypic markers were not expressed in control or FGF-2 groups. FGF-2 did prevent the development of a “fibroblastic” cell layer around pellet periphery. FGF-2 significantly accelerates in vitro SF-CP expansion, the major hurdle to clinical application of this cell population, without detrimentally affecting subsequent chondrogenic capacity.

  2. Computer controlled high voltage system

    Energy Technology Data Exchange (ETDEWEB)

    Kunov, B; Georgiev, G; Dimitrov, L [and others

    1996-12-31

    A multichannel computer controlled high-voltage power supply system is developed. The basic technical parameters of the system are: output voltage -100-3000 V, output current - 0-3 mA, maximum number of channels in one crate - 78. 3 refs.

  3. A single gas chromatograph for accurate atmospheric mixing ratio measurements of CO2, CH4, N2O, SF6 and CO

    NARCIS (Netherlands)

    van der Laan, S.; Neubert, R. E. M.; Meijer, H. A. J.; Simpson, W.R.

    2009-01-01

    We present an adapted gas chromatograph capable of measuring simultaneously and semi-continuously the atmospheric mixing ratios of the greenhouse gases CO2, CH4, N2O and SF6 and the trace gas CO with high precision and long-term stability. The novelty of our design is that all species are measured

  4. Ozone-depleting substances and the greenhouse gases HFCs, PFCs and SF{sub 6}. Danish consumption and emissions, 2005

    Energy Technology Data Exchange (ETDEWEB)

    Sander Poulsen, T. [PlanMiljoe (Denmark)

    2007-06-15

    An evaluation of Danish consumption and emissions of ozone-depleting substances and industrial greenhouse gases has been carried out in continuation of previous evaluations, partly to fulfil Denmark's international obligations to provide information within this area and partly to follow the trend in consumption of ozone-depleting substances as well as the consumption and emissions of HFCs, PFCs and SF{sub 6}. The evaluation includes a calculation of actual emissions of HFCs, PFCs, and SF{sub 6} for 2006. In this calculation the release from stock of greenhouse gases in products has been taken into account, and adjustments have been made for imports and exports of the greenhouse gases in products. (BA)

  5. High voltage distributions in RPCs

    International Nuclear Information System (INIS)

    Inoue, Y.; Muranishi, Y.; Nakamura, M.; Nakano, E.; Takahashi, T.; Teramoto, Y.

    1996-01-01

    High voltage distributions on the inner surfaces of RPCs electrodes were calculated by using a two-dimensional resistor network model. The calculated result shows that the surface resistivity of the electrodes should be high, compared to their volume resistivity, to get a uniform high voltage over the surface. Our model predicts that the rate capabilities of RPCs should be inversely proportional to the thickness of the electrodes if the ratio of surface-to-volume resistivity is low. (orig.)

  6. An Improved SF6 System for the FXR Induction Linac Blumlein Switches

    International Nuclear Information System (INIS)

    DeHope, W; Kihara, R; Griffin, K L; Ong, M; Ross, T

    2007-01-01

    The now-mature FXR (Flash X-Ray) radiographic facility at Lawrence Livermore National Laboratory will be briefly described with emphasis on its pulsed power system. The heart of each accelerating cell's pulse forming Blumlein is it's sulfur hexafluoride-based triggered closing switch. FXR's recent upgrade to a recirculating SF 6 gas reclamation system will be described and the resulting accelerator performance and reliability improvements documented. This was accompanied by a detailed switch breakdown study on FXR's Test Stand and the recent analysis of the resulting statistics will be shown

  7. High-voltage CMOS detectors

    International Nuclear Information System (INIS)

    Ehrler, F.; Blanco, R.; Leys, R.; Perić, I.

    2016-01-01

    High-voltage CMOS (HVCMOS) pixel sensors are depleted active pixel sensors implemented in standard commercial CMOS processes. The sensor element is the n-well/p-substrate diode. The sensor electronics are entirely placed inside the n-well which is at the same time used as the charge collection electrode. High voltage is used to deplete the part of the substrate around the n-well. HVCMOS sensors allow implementation of complex in-pixel electronics. This, together with fast signal collection, allows a good time resolution, which is required for particle tracking in high energy physics. HVCMOS sensors will be used in Mu3e experiment at PSI and are considered as an option for both ATLAS and CLIC (CERN). Radiation tolerance and time walk compensation have been tested and results are presented. - Highlights: • High-voltage CMOS sensors will be used in Mu3e experiment at PSI (Switzerland). • HVCMOS sensors are considered as an option for ATLAS (LHC/CERN) and CLIC (CERN). • Efficiency of more than 95% (99%) has been measured with (un-)irradiated chips. • The time resolution measured in the beam tests is nearly 100 ns. • We plan to improve time resolution and efficiency by using high-resistive substrate.

  8. High-voltage CMOS detectors

    Energy Technology Data Exchange (ETDEWEB)

    Ehrler, F., E-mail: felix.ehrler@student.kit.edu; Blanco, R.; Leys, R.; Perić, I.

    2016-07-11

    High-voltage CMOS (HVCMOS) pixel sensors are depleted active pixel sensors implemented in standard commercial CMOS processes. The sensor element is the n-well/p-substrate diode. The sensor electronics are entirely placed inside the n-well which is at the same time used as the charge collection electrode. High voltage is used to deplete the part of the substrate around the n-well. HVCMOS sensors allow implementation of complex in-pixel electronics. This, together with fast signal collection, allows a good time resolution, which is required for particle tracking in high energy physics. HVCMOS sensors will be used in Mu3e experiment at PSI and are considered as an option for both ATLAS and CLIC (CERN). Radiation tolerance and time walk compensation have been tested and results are presented. - Highlights: • High-voltage CMOS sensors will be used in Mu3e experiment at PSI (Switzerland). • HVCMOS sensors are considered as an option for ATLAS (LHC/CERN) and CLIC (CERN). • Efficiency of more than 95% (99%) has been measured with (un-)irradiated chips. • The time resolution measured in the beam tests is nearly 100 ns. • We plan to improve time resolution and efficiency by using high-resistive substrate.

  9. Linear thermal expansion measurements on silicon from 6 to 340 K

    International Nuclear Information System (INIS)

    Lyon, K.G.; Salinger, G.L.; Swenson, C.A.; White, G.K.

    1977-01-01

    Linear thermal expansion measurements have been carried out from 6 to 340 K on a high-purity silicon sample using a linear absolute capacitance dilatometer. The accuracy of the measurements varies from +- 0.01 x 10 -8 K -1 at the lowest temperatures to +- 0.1 x 10 -8 K -1 or 0.1%, whichever is greater, near room temperature, and is sufficient to establish silicon as a thermal expansion standard for these temperatures. The agreement with previous data is satisfactory at low temperatures and excellent above room temperature where laser-interferometry data of comparable accuracy exist. Thermal expansions calculated from ultrasonic and heat-capacity data are preferred below 13 K where experimental problems occurred

  10. Thermal expansion studies of ThW2O8 and UWO6

    International Nuclear Information System (INIS)

    Keskar, Meera; Krishnan, K.; Sali, S.K.

    2014-01-01

    Thorium and uranium oxysalts with hexavalent cations of elements of VI th group of the periodic table are important from mineralogical, environmental and technological points of view. Several molybdates and tungstates of uranium and thorium are known to have similar structural and thermo-physical properties. Earlier, thermal expansion behavior of ThMo 2 O 8 and UMoO 6 were reported from our laboratory. In the present work, thermal expansion behavior of ThW 2 O 8 and UWO 6 studied under vacuum from ambient to 1000 and 800℃, respectively using high temperature X-ray diffraction (HTXRD) technique is reported

  11. High voltage high brightness electron accelerators with MITL voltage adder coupled to foilless diodes

    International Nuclear Information System (INIS)

    Mazarakis, M.G.; Poukey, J.W.; Frost, C.A.; Shope, S.L.; Halbleib, J.A.; Turman, B.N.

    1993-01-01

    During the last ten years the authors have extensively studied the physics and operation of magnetically-immersed electron foilless diodes. Most of these sources were utilized as injectors to high current, high energy linear induction accelerators such as those of the RADLAC family. Recently they have experimentally and theoretically demonstrated that foilless diodes can be successfully coupled to self-magnetically insulated transmission line voltage adders to produce very small high brightness, high definition (no halo) electron beams. The RADLAC/SMILE experience opened the path to a new approach in high brightness, high energy induction accelerators. There is no beam drifting through the device. The voltage addition occurs in a center conductor, and the beam is created at the high voltage end in an applied magnetic field diode. This work was motivated by the remarkable success of the HERMES-III accelerator and the need to produce small radius, high energy, high current electron beams for air propagation studies and flash x-ray radiography. In this paper they present experimental results compared with analytical and numerical simulations in addition to design examples of devices that can produce multikiloamp electron beams of as high as 100 MV energies and radii as small as 1 mm

  12. A High-Voltage Level Tolerant Transistor Circuit

    NARCIS (Netherlands)

    Annema, Anne J.; Geelen, Godefridus Johannes Gertrudis Maria

    2001-01-01

    A high-voltage level tolerant transistor circuit, comprising a plurality of cascoded transistors, including a first transistor (T1) operatively connected to a high-voltage level node (3) and a second transistor (T2) operatively connected to a low-voltage level node (2). The first transistor (T1)

  13. Low-temperature thermal expansion of pure and inert gas-doped fullerite C sub 6 sub 0

    CERN Document Server

    Aleksandrovskii, A N; Eselson, V B; Gavrilko, V G; Manzhelii, V G; Udovidchenko, B G; Bakai, A S; Gadd, G E; Moricca, S; Sundqvist, B

    2003-01-01

    The low temperature (2-24 K) thermal expansion of pure (single-crystal and polycrystalline) C sub 6 sub 0 and polycrystalline C sub 6 sub 0 intercalated with He, Ne, Ar, and Kr has been investigated using the high-resolution capacitance dilatometer. The investigation of the time dependence of the sample length variations DELTA L(t) on heating by DELTA T shows that the thermal expansion is determined by the sum of positive and negative contributions, which have different relaxation times. The negative thermal expansion usually prevails at helium temperatures. The positive expansion is connected with the phonon thermalization of the system. The negative expansion is caused by reorientation of the C sub 6 sub 0 molecules. It is assumed that the reorientation is of a quantum character. The inert gas impurities affect the reorientation of the C6 sub sub 0 molecules very strongly, especially at liquid helium temperatures. A temperature hysteresis of the thermal expansion coefficient of Kr- and He-C sub 6 sub 0 solu...

  14. Comparison of Sulfur Hexafluoride (SF6) and Air Tamponade in Noniridectomized Descemet Membrane Endothelial Keratoplasty.

    Science.gov (United States)

    Einan-Lifshitz, Adi; Sorkin, Nir; Boutin, Tanguy; Showail, Mahmood; Borovik, Armand; Jamshidi, Farzad; Chan, Clara C; Rootman, David S

    2018-03-01

    To compare the efficacy and safety of 20% sulfur hexafluoride gas (SF6) and air tamponade in patients who underwent noniridectomized Descemet membrane endothelial keratoplasty (DMEK). A retrospective chart review of patients who underwent DMEK with either air or SF6 tamponade: 41 eyes received air tamponade (group 1) and 41 received SF6 tamponade (group 2). Best spectacle-corrected visual acuity, endothelial cell density, and complications including graft detachment and elevated intraocular pressure were compared. The mean follow-up time was 8 ± 4 months in group 1 and 3 ± 2 months in group 2. Mean best spectacle-corrected visual acuity improved from 1.12 ± 0.88 to 0.64 ± 0.78 logarithm of the minimum angle of resolution (logMAR) in group 1 (P = 0.009) and from 1.00 ± 0.78 to 0.62 ± 0.53 logMAR in group 2 (P = 0.006). The graft detachment rate was 39% (16 eyes) in group 1 and 42% (17 eyes) in group 2 (P = 0.822). The rate of graft detachment larger than one third of the graft area was 17% in group 1 and 20% in group 2 (P = 0.775). Rebubbling was performed in 26.8% and 20% of eyes in group 1 and 2, respectively (P = 0.43). Average endothelial cell loss was 32% in group 1 and 33% in group 2 (P = 0.83). In the immediate postoperative period, elevated intraocular pressure was observed in 2 eyes (5%) in group 1 and in 4 eyes (10%) in group 2 (P = 0.4). There was 1 primary graft failure in each group. Use of air with it being readily available and short acting is a good method of Descemet membrane tamponade in noniridectomized DMEK.

  15. Advances in high voltage power switching with GTOs

    International Nuclear Information System (INIS)

    Podlesak, T.F.

    1990-01-01

    The control of high voltage at high power, particularly opening switches, has been difficult in the past. Using gate turnoff thyristors (GTOs) arranged in series enables large currents to be switched at high voltage. The authors report a high voltage opening switch has been successfully demonstrated. This switch uses GTOs in series and successfully operates at voltages higher than the rated voltage of the individual devices. It is believed that this is the first time this has been successfully demonstrated, in that GTOs have been operated in series before, but always in a manner as to not exceed the voltage capability of the individual devices. In short, the devices have not worked together, sharing the voltage, but one device has been operated using several backup devices. Of particular interest is how well the individual devices share the voltage applied to them. Equal voltage sharing between devices is absolutely essential, in order to not exceed the voltage rating of any of the devices in the series chain. This is accomplished at high (microsecond) switching speeds. Thus, the system is useful for high frequency applications as well as high power, making for a flexible circuit system element. This demonstration system is rated at 5 KV and uses 1 KV devices. A larger 24 KV system is under design and will use 4.5 KV devices. In order to design the 24 KV switch, the safe operating area of the large devices must be known thoroughly

  16. [Auto-immune disorders as a possible cause of neuropsychiatric syndromes].

    Science.gov (United States)

    Martinez-Martinez, P; Molenaar, P C; Losen, M; Hoffmann, C; Stevens, J; de Witte, L D; van Amelsvoort, T; van Os, J; Rutten, B P F

    2015-01-01

    Changes that occur in the behaviour of voltage-gated ion channels and ligand-gated receptor channels due to gene mutations or auto-immune attack are the cause of channelopathies in the central and peripheral nervous system. Although the relation between molecular channel defects and clinical symptoms has been explained in the case of many neuromuscular channelopathies, the pathophysiology of auto-immunity in neuropsychiatric syndromes is still unclear. To review recent findings regarding neuronal auto-immune reactions in severe neuropsychiatric syndromes. Using PubMed, we consulted the literature published between 1990 and August 2014 relating to the occurrence of auto-immune antibodies in severe and persistent neuropsychiatric syndromes. Auto-antibodies have only limited access to the central nervous system, but if they do enter the system they can, in some cases, cause disease. We discuss recent findings regarding the occurrence of auto-antibodies against ligand-activated receptor channels and potassium channels in neuropsychiatric and neurological syndromes, including schizophrenia and limbic encephalitis. Although the occurrence of several auto-antibodies in schizophrenia has been confirmed, there is still no proof of a causal relationship in the syndrome. We still have no evidence of the prevalence of auto-immunity in neuropsychiatric syndromes. The discovery that an antibody against an ion channel is associated with some neuropsychiatric disorders may mean that in future it will be possible to treat patients by means of immunosuppression, which could lead to an improvement in a patient's cognitive abilities.

  17. Transport coefficients of liquid CF4 and SF6 computed by molecular dynamics using polycenter Lennard-Jones potentials

    International Nuclear Information System (INIS)

    Hoheisel, C.

    1989-01-01

    For several liquid states of CF 4 and SF 6 , the shear and the bulk viscosity as well as the thermal conductivity were determined by equilibrium molecular dynamics (MD) calculations. Lennard-Jones four- and six-center pair potentials were applied, and the method of constraints were chosen for the MD. The computed Green-Kubo integrands show a steep time decay, and no particular longtime behavior occurs. The molecule number dependence of the results is found to be small, and 3 x 10 5 integration steps allow an accuracy of about 10% for the shear viscosity and the thermal conductivity coefficient. Comparison with experimental data shows a fair agreement for CF 4 , while for SF 6 the transport coefficients fall below the experimental ones by about 30%

  18. High frequency relay protection channels on super high voltage lines

    Energy Technology Data Exchange (ETDEWEB)

    Mikutskii, G V

    1964-08-01

    General aspects of high voltage transmission line design are discussed. The relationships between line voltage and length and line dimensions and power losses are explained. Electrical interference in the line is classified under three headings: interference under normal operating conditions, interference due to insulation faults, and interference due to variations in operating conditions of the high-voltage network.

  19. An asymmetric MOSFET-C band-pass filter with on-chip charge pump auto-tuning

    International Nuclear Information System (INIS)

    Chen Fangxiong; Ma Heping; Jia Hailong; Shi Yin; Lin Min; Dai, Forster

    2009-01-01

    An asymmetric MOSFET-C band-pass filter (BPF) with on chip charge pump auto-tuning is presented. It is implemented in UMC (United Manufacturing Corporation) 0.18 μm CMOS process technology. The filter system with auto-tuning uses a master-slave technique for continuous tuning in which the charge pump outputs 2.663 V, much higher than the power supply voltage, to improve the linearity of the filter. The main filter with third order low-pass and second order high-pass properties is an asymmetric band-pass filter with bandwidth of 2.730-5.340 MHz. The in-band third order harmonic input intercept point (IIP3) is 16.621 dBm, with 50 Ω as the source impedance. The input referred noise is about 47.455 μV rms . The main filter dissipates 3.528 mW while the auto-tuning system dissipates 2.412 mW from a 1.8 V power supply. The filter with the auto-tuning system occupies 0.592 mm 2 and it can be utilized in GPS (global positioning system) and Bluetooth systems. (semiconductor integrated circuits)

  20. An asymmetric MOSFET-C band-pass filter with on-chip charge pump auto-tuning

    Energy Technology Data Exchange (ETDEWEB)

    Chen Fangxiong; Ma Heping; Jia Hailong; Shi Yin [Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083 (China); Lin Min [Suzhou-CAS Semiconductors Integrated Technology Research Center, Suzhou 215021 (China); Dai, Forster, E-mail: fxchen@semi.ac.c [Department of Electrical and Computer Engineering, Auburn University, AL 36849 (United States)

    2009-08-15

    An asymmetric MOSFET-C band-pass filter (BPF) with on chip charge pump auto-tuning is presented. It is implemented in UMC (United Manufacturing Corporation) 0.18 {mu}m CMOS process technology. The filter system with auto-tuning uses a master-slave technique for continuous tuning in which the charge pump outputs 2.663 V, much higher than the power supply voltage, to improve the linearity of the filter. The main filter with third order low-pass and second order high-pass properties is an asymmetric band-pass filter with bandwidth of 2.730-5.340 MHz. The in-band third order harmonic input intercept point (IIP3) is 16.621 dBm, with 50 {Omega} as the source impedance. The input referred noise is about 47.455 {mu}V{sub rms}. The main filter dissipates 3.528 mW while the auto-tuning system dissipates 2.412 mW from a 1.8 V power supply. The filter with the auto-tuning system occupies 0.592 mm{sup 2} and it can be utilized in GPS (global positioning system) and Bluetooth systems. (semiconductor integrated circuits)

  1. The Signal Detection and Control Circuit Design for Confocal Auto-Focus System

    OpenAIRE

    Yin Liu; Jin Yu; Zeqiang Mo

    2016-01-01

    Based on the demands of Confocal Auto-Focus system, the implementation method of signal measurement circuit and control circuit is given. Using the high performance instrumental amplifier AD620BN, low noise precision FET Op amplifier AD795JRZ and ultralow offset voltage Op amplifier OP07EP, a signal measurement circuit used to converse the two differential light intensity signal to electric signal is designed. And a control circuit which takes MCU MSP430F149 as core processes the former signa...

  2. Camera system considerations for geomorphic applications of SfM photogrammetry

    Science.gov (United States)

    Mosbrucker, Adam; Major, Jon J.; Spicer, Kurt R.; Pitlick, John

    2017-01-01

    The availability of high-resolution, multi-temporal, remotely sensed topographic data is revolutionizing geomorphic analysis. Three-dimensional topographic point measurements acquired from structure-from-motion (SfM) photogrammetry have been shown to be highly accurate and cost-effective compared to laser-based alternatives in some environments. Use of consumer-grade digital cameras to generate terrain models and derivatives is becoming prevalent within the geomorphic community despite the details of these instruments being largely overlooked in current SfM literature. This article is protected by copyright. All rights reserved.A practical discussion of camera system selection, configuration, and image acquisition is presented. The hypothesis that optimizing source imagery can increase digital terrain model (DTM) accuracy is tested by evaluating accuracies of four SfM datasets conducted over multiple years of a gravel bed river floodplain using independent ground check points with the purpose of comparing morphological sediment budgets computed from SfM- and lidar-derived DTMs. Case study results are compared to existing SfM validation studies in an attempt to deconstruct the principle components of an SfM error budget. This article is protected by copyright. All rights reserved.Greater information capacity of source imagery was found to increase pixel matching quality, which produced 8 times greater point density and 6 times greater accuracy. When propagated through volumetric change analysis, individual DTM accuracy (6–37 cm) was sufficient to detect moderate geomorphic change (order 100,000 m3) on an unvegetated fluvial surface; change detection determined from repeat lidar and SfM surveys differed by about 10%. Simple camera selection criteria increased accuracy by 64%; configuration settings or image post-processing techniques increased point density by 5–25% and decreased processing time by 10–30%. This article is protected by copyright. All rights

  3. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based......, and remote power generation for light towers, camper vans, boats, beacons, and buoys etc. A review of current state-of-the-art is presented. The best performing converters achieve moderately high peak efficiencies at high input voltage and medium power level. However, system dimensioning and cost are often...

  4. s-wave threshold in electron attachment - Observations and cross sections in CCl4 and SF6 at ultralow electron energies

    Science.gov (United States)

    Chutjian, A.; Alajajian, S. H.

    1985-01-01

    The threshold photoionization method was used to study low-energy electron attachment phenomena in and cross sections of CCl4 and SF6 compounds, which have applications in the design of gaseous dielectrics and diffuse discharge opening switches. Measurements were made at electron energies from below threshold to 140 meV at resolutions of 6 and 8 meV. A narrow resolution-limited structure was observed in electron attachment to CCl4 and SF6 at electron energies below 10 meV, which is attributed to the divergence of the attachment cross section in the limit epsilon, l approaches zero. The results are compared with experimental collisional-ionization results, electron-swarm unfolded cross sections, and earlier threshold photoionization data.

  5. A Sepic Type Switched Mode Power Supply System For Battery Charging In An Electric Tricycle Auto-Rickshaw

    Directory of Open Access Journals (Sweden)

    Kureve

    2017-08-01

    Full Text Available This paper analyzes the plug-in electric tricycle Auto rickshaw battery charging system using a non-isolated DC-DC SEPIC converter which operates as a switched mode power supply SMPS. The control of dc voltage output is by varying the gating pulses duty cycle of the switch in the dc-dc converter using PID controller based PWM technique. The 60 V 30 A DC-DC SEPIC converter is designed to provide non-inverting voltage buck from the rectified AC mains for charging deep cycle battery bank in an electric auto rickshaw. The charger system is implemented using MATLABSimulink.

  6. Enhanced electrochemical performance of LiNi0.6Co0.2Mn0.2O2 cathode at high cutoff voltage by modifying electrode/electrolyte interface with lithium metasilicate

    International Nuclear Information System (INIS)

    Fu, Jiale; Mu, Daobin; Wu, Borong; Bi, Jiaying; Liu, Xiaojiang; Peng, Yiyuan; Li, Yiqing; Wu, Feng

    2017-01-01

    Highlights: •The electrochemical properties of the LiNi 0.6 Co 0.2 Mn 0.2 O 2 cathode are investigated at high voltage of 4.6 V. •The Li 2 SiO 3 suppresses the decomposition of LiPF 6 and carbonate solvents. •Li 2 SiO 3 helpfully retards the transition metal dissolution by consuming HF. •The enhanced electrochemical properties of the LiNi 0.6 Co 0.2 Mn 0.2 O 2 cathode mixed with Li 2 SiO 3 . -- Abstract: Developing high-voltage Li ion batteries (LIBs) is an important trend to meet the requirement of high energy density battery. However, high voltage will cause a series of problems harming the cycle performance of LIBs at the same time. This work is to investigate the effect of inorganic substance Li 2 SiO 3 on the electrochemical performance of LiNi 0.6 Co 0.2 Mn 0.2 O 2 (NCM622) cathode at high cutoff voltage of 4.6 V. XRD result shows that the structure of NCM622 cathode material is not affected by mixing Li 2 SiO 3 . However, XPS and EIS tests indicate that Li 2 SiO 3 has an evident influence on suppressing the decomposition of LiPF 6 and carbonate solvents at high voltage, reducing interfacial solid film impedance and modifying electrode/electrolyte interface. In addition, Li 2 SiO 3 retards the transition metal dissolution by consuming HF. Therefore, it enhances the electrochemical properties of the NCM622 cathode significantly. The highest discharge capacity increases to 191.7 mA h g -1 by mixing Li 2 SiO 3 , compared with the value of 180 mA h g -1 in the case of NCM622 cathode. The NCM622 electrode mixed with Li 2 SiO 3 also exhibits a better capacity retention of 73.4% after 200 cycles and a high rate capability at 20C with the value of 89 mA h g -1 , in contrast with 62.2% and 31 mA h g -1 attained in the NCM622 cathode.

  7. Deep reactive ion etching of 4H-SiC via cyclic SF6/O2 segments

    International Nuclear Information System (INIS)

    Luna, Lunet E; Tadjer, Marko J; Anderson, Travis J; Imhoff, Eugene A; Hobart, Karl D; Kub, Fritz J

    2017-01-01

    Cycles of inductively coupled SF 6 /O 2 plasma with low (9%) and high (90%) oxygen content etch segments are used to produce up to 46.6 µ m-deep trenches with 5.5 µ m-wide openings in single-crystalline 4H-SiC substrates. The low oxygen content segment serves to etch deep in SiC whereas the high oxygen content segment serves to etch SiC at a slower rate, targeting carbon-rich residues on the surface as the combination of carbon-rich and fluorinated residues impact sidewall profile. The cycles work in concert to etch past 30 µ m at an etch rate of ∼0.26 µ m min −1 near room temperature, while maintaining close to vertical sidewalls, high aspect ratio, and high mask selectivity. In addition, power ramps during the low oxygen content segment is used to produce a 1:1 ratio of mask opening to trench bottom width. The effect of process parameters such as cycle time and backside substrate cooling on etch depth and micromasking of the electroplated nickel etch mask are investigated. (paper)

  8. High voltage electricity installations a planning perspective

    CERN Document Server

    Jay, Stephen Andrew

    2006-01-01

    The presence of high voltage power lines has provoked widespread concern for many years. High Voltage Electricity Installations presents an in-depth study of policy surrounding the planning of high voltage installations, discussing the manner in which they are percieved by the public, and the associated environmental issues. An analysis of these concerns, along with the geographical, environmental and political influences that shape their expression, is presented. Investigates local planning policy in an area of the energy sector that is of highly topical environmental and public concern Cover

  9. Surface interactions involved in flashover with high density electronegative gases.

    Energy Technology Data Exchange (ETDEWEB)

    Hodge, Keith Conquest; Warne, Larry Kevin; Jorgenson, Roy Eberhardt; Wallace, Zachariah Red; Lehr, Jane Marie

    2010-01-01

    This report examines the interactions involved with flashover along a surface in high density electronegative gases. The focus is on fast ionization processes rather than the later time ionic drift or thermalization of the discharge. A kinetic simulation of the gas and surface is used to examine electron multiplication and includes gas collision, excitation and ionization, and attachment processes, gas photoionization and surface photoemission processes, as well as surface attachment. These rates are then used in a 1.5D fluid ionization wave (streamer) model to study streamer propagation with and without the surface in air and in SF6. The 1.5D model therefore includes rates for all these processes. To get a better estimate for the behavior of the radius we have studied radial expansion of the streamer in air and in SF6. The focus of the modeling is on voltage and field level changes (with and without a surface) rather than secondary effects, such as, velocities or changes in discharge path. An experiment has been set up to carry out measurements of threshold voltages, streamer velocities, and other discharge characteristics. This setup includes both electrical and photographic diagnostics (streak and framing cameras). We have observed little change in critical field levels (where avalanche multiplication sets in) in the gas alone versus with the surface. Comparisons between model calculations and experimental measurements are in agreement with this. We have examined streamer sustaining fields (field which maintains ionization wave propagation) in the gas and on the surface. Agreement of the gas levels with available literature is good and agreement between experiment and calculation is good also. Model calculations do not indicate much difference between the gas alone versus the surface levels. Experiments have identified differences in velocity between streamers on the surface and in the gas alone (the surface values being larger).

  10. The eGo grid model: An open source approach towards a model of German high and extra-high voltage power grids

    Science.gov (United States)

    Mueller, Ulf Philipp; Wienholt, Lukas; Kleinhans, David; Cussmann, Ilka; Bunke, Wolf-Dieter; Pleßmann, Guido; Wendiggensen, Jochen

    2018-02-01

    There are several power grid modelling approaches suitable for simulations in the field of power grid planning. The restrictive policies of grid operators, regulators and research institutes concerning their original data and models lead to an increased interest in open source approaches of grid models based on open data. By including all voltage levels between 60 kV (high voltage) and 380kV (extra high voltage), we dissolve the common distinction between transmission and distribution grid in energy system models and utilize a single, integrated model instead. An open data set for primarily Germany, which can be used for non-linear, linear and linear-optimal power flow methods, was developed. This data set consists of an electrically parameterised grid topology as well as allocated generation and demand characteristics for present and future scenarios at high spatial and temporal resolution. The usability of the grid model was demonstrated by the performance of exemplary power flow optimizations. Based on a marginal cost driven power plant dispatch, being subject to grid restrictions, congested power lines were identified. Continuous validation of the model is nescessary in order to reliably model storage and grid expansion in progressing research.

  11. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based...

  12. Asymptotic expansions for high-contrast elliptic equations

    KAUST Repository

    Calo, Victor M.; Efendiev, Yalchin R.; Galvis, Juan

    2014-01-01

    In this paper, we present a high-order expansion for elliptic equations in high-contrast media. The background conductivity is taken to be one and we assume the medium contains high (or low) conductivity inclusions. We derive an asymptotic expansion with respect to the contrast and provide a procedure to compute the terms in the expansion. The computation of the expansion does not depend on the contrast which is important for simulations. The latter allows avoiding increased mesh resolution around high conductivity features. This work is partly motivated by our earlier work in [Domain decomposition preconditioners for multiscale flows in high-contrast media, Multiscale Model Simul. 8 (2010) 1461-1483] where we design efficient numerical procedures for solving high-contrast problems. These multiscale approaches require local solutions and our proposed high-order expansion can be used to approximate these local solutions inexpensively. In the case of a large-number of inclusions, the proposed analysis can help to design localization techniques for computing the terms in the expansion. In the paper, we present a rigorous analysis of the proposed high-order expansion and estimate the remainder of it. We consider both high-and low-conductivity inclusions. © 2014 World Scientific Publishing Company.

  13. Asymptotic expansions for high-contrast elliptic equations

    KAUST Repository

    Calo, Victor M.

    2014-03-01

    In this paper, we present a high-order expansion for elliptic equations in high-contrast media. The background conductivity is taken to be one and we assume the medium contains high (or low) conductivity inclusions. We derive an asymptotic expansion with respect to the contrast and provide a procedure to compute the terms in the expansion. The computation of the expansion does not depend on the contrast which is important for simulations. The latter allows avoiding increased mesh resolution around high conductivity features. This work is partly motivated by our earlier work in [Domain decomposition preconditioners for multiscale flows in high-contrast media, Multiscale Model Simul. 8 (2010) 1461-1483] where we design efficient numerical procedures for solving high-contrast problems. These multiscale approaches require local solutions and our proposed high-order expansion can be used to approximate these local solutions inexpensively. In the case of a large-number of inclusions, the proposed analysis can help to design localization techniques for computing the terms in the expansion. In the paper, we present a rigorous analysis of the proposed high-order expansion and estimate the remainder of it. We consider both high-and low-conductivity inclusions. © 2014 World Scientific Publishing Company.

  14. High Voltage Seismic Generator

    Science.gov (United States)

    Bogacz, Adrian; Pala, Damian; Knafel, Marcin

    2015-04-01

    This contribution describes the preliminary result of annual cooperation of three student research groups from AGH UST in Krakow, Poland. The aim of this cooperation was to develop and construct a high voltage seismic wave generator. Constructed device uses a high-energy electrical discharge to generate seismic wave in ground. This type of device can be applied in several different methods of seismic measurement, but because of its limited power it is mainly dedicated for engineering geophysics. The source operates on a basic physical principles. The energy is stored in capacitor bank, which is charged by two stage low to high voltage converter. Stored energy is then released in very short time through high voltage thyristor in spark gap. The whole appliance is powered from li-ion battery and controlled by ATmega microcontroller. It is possible to construct larger and more powerful device. In this contribution the structure of device with technical specifications is resented. As a part of the investigation the prototype was built and series of experiments conducted. System parameter was measured, on this basis specification of elements for the final device were chosen. First stage of the project was successful. It was possible to efficiently generate seismic waves with constructed device. Then the field test was conducted. Spark gap wasplaced in shallowborehole(0.5 m) filled with salt water. Geophones were placed on the ground in straight line. The comparison of signal registered with hammer source and sparker source was made. The results of the test measurements are presented and discussed. Analysis of the collected data shows that characteristic of generated seismic signal is very promising, thus confirms possibility of practical application of the new high voltage generator. The biggest advantage of presented device after signal characteristics is its size which is 0.5 x 0.25 x 0.2 m and weight approximately 7 kg. This features with small li-ion battery makes

  15. SEMICONDUCTOR INTEGRATED CIRCUITS: An asymmetric MOSFET-C band-pass filter with on-chip charge pump auto-tuning

    Science.gov (United States)

    Fangxiong, Chen; Min, Lin; Heping, Ma; Hailong, Jia; Yin, Shi; Forster, Dai

    2009-08-01

    An asymmetric MOSFET-C band-pass filter (BPF) with on chip charge pump auto-tuning is presented. It is implemented in UMC (United Manufacturing Corporation) 0.18 μm CMOS process technology. The filter system with auto-tuning uses a master-slave technique for continuous tuning in which the charge pump outputs 2.663 V, much higher than the power supply voltage, to improve the linearity of the filter. The main filter with third order low-pass and second order high-pass properties is an asymmetric band-pass filter with bandwidth of 2.730-5.340 MHz. The in-band third order harmonic input intercept point (IIP3) is 16.621 dBm, with 50 Ω as the source impedance. The input referred noise is about 47.455 μVrms. The main filter dissipates 3.528 mW while the auto-tuning system dissipates 2.412 mW from a 1.8 V power supply. The filter with the auto-tuning system occupies 0.592 mm2 and it can be utilized in GPS (global positioning system) and Bluetooth systems.

  16. Voltage generators of high voltage high power accelerators

    International Nuclear Information System (INIS)

    Svinin, M.P.

    1981-01-01

    High voltage electron accelerators are widely used in modern radiation installations for industrial purposes. In the near future further increasing of their power may be effected, which enables to raise the efficiency of the radiation processes known and to master new power-consuming production in industry. Improvement of HV generators by increasing their power and efficiency is one of many scientific and engineering aspects the successful solution of which provides further development of these accelerators and their technical parameters. The subject is discussed in detail. (author)

  17. Neuroprotective effect of interleukin-6 regulation of voltage-gated Na+ channels of cortical neurons is time- and dose-dependent

    Directory of Open Access Journals (Sweden)

    Wei Xia

    2015-01-01

    Full Text Available Interleukin-6 has been shown to be involved in nerve injury and nerve regeneration, but the effects of long-term administration of high concentrations of interleukin-6 on neurons in the central nervous system is poorly understood. This study investigated the effects of 24 hour exposure of interleukin-6 on cortical neurons at various concentrations (0.1, 1, 5 and 10 ng/mL and the effects of 10 ng/mL interleukin-6 exposure to cortical neurons for various durations (2, 4, 8, 24 and 48 hours by studying voltage-gated Na + channels using a patch-clamp technique. Voltage-clamp recording results demonstrated that interleukin-6 suppressed Na + currents through its receptor in a time- and dose-dependent manner, but did not alter voltage-dependent activation and inactivation. Current-clamp recording results were consistent with voltage-clamp recording results. Interleukin-6 reduced the action potential amplitude of cortical neurons, but did not change the action potential threshold. The regulation of voltage-gated Na + channels in rat cortical neurons by interleukin-6 is time- and dose-dependent.

  18. Comparison of the SF6D, the EQ5D, and the oswestry disability index in patients with chronic low back pain and degenerative disc disease.

    Science.gov (United States)

    Johnsen, Lars G; Hellum, Christian; Nygaard, Oystein P; Storheim, Kjersti; Brox, Jens I; Rossvoll, Ivar; Leivseth, Gunnar; Grotle, Margreth

    2013-04-26

    The need for cost effectiveness analyses in randomized controlled trials that compare treatment options is increasing. The selection of the optimal utility measure is important, and a central question is whether the two most commonly used indexes - the EuroQuol 5D (EQ5D) and the Short Form 6D (SF6D) - can be used interchangeably. The aim of the present study was to compare change scores of the EQ5D and SF6D utility indexes in terms of some important measurement properties. The psychometric properties of the two utility indexes were compared to a disease-specific instrument, the Oswestry Disability Index (ODI), in the setting of a randomized controlled trial for degenerative disc disease. In a randomized controlled multicentre trial, 172 patients who had experienced low back pain for an average of 6 years were randomized to either treatment with an intensive back rehabilitation program or surgery to insert disc prostheses. Patients filled out the ODI, EQ5D, and SF-36 at baseline and two-year follow up. The utility indexes was compared with respect to measurement error, structural validity, criterion validity, responsiveness, and interpretability according to the COSMIN taxonomy. At follow up, 113 patients had change score values for all three instruments. The SF6D had better similarity with the disease-specific instrument (ODI) regarding sensitivity, specificity, and responsiveness. Measurement error was lower for the SF6D (0.056) compared to the EQ5D (0.155). The minimal important change score value was 0.031 for SF6D and 0.173 for EQ5D. The minimal detectable change score value at a 95% confidence level were 0.157 for SF6D and 0.429 for EQ5D, and the difference in mean change score values (SD) between them was 0.23 (0.29) and so exceeded the clinical significant change score value for both instruments. Analysis of psychometric properties indicated that the indexes are unidimensional when considered separately, but that they do not exactly measure the same

  19. [High voltage accidents, characteristics and treatment].

    Science.gov (United States)

    Hülsbergen-Krüger, S; Pitzler, D; Partecke, B D

    1995-04-01

    High-voltage injuries cause localised entrance and exit burns, extensive arc, flame and flash burns and, even more dangerous, necrosis of the underlying muscles on the pathway of the current through the body. Therefore it should be recognized that the ensuing disease is more like a crush injury than a thermal burn. The extent of injury cannot be judged by the percentage and depth of the skin burn. Diagnostic fasciotomies, radical debridement, and in many cases early amputation are necessary to prevent life-threatening complications. Over a period of 10 years, 43 patients with high-voltage injuries have been treated at the Hamburg Burn Center, 36 of them in primary care. Common causes of injury were accidents in railway areas (28%), using portable aluminium ladders near overhead power lines (9.3%), and working on electrical equipment (30.2%). Six of the primary care patients died (16.6%), and 34.9% had an amputation of one or more extremities. Nearly all patients underwent several debridement and split-skin graft procedures. In 30% of cases additional free and pedicled flaps were needed to cover soft tissue defects. Ten patients (23.3%) sustained fractures and other injuries from falls, seven (16.3%) of them severe polytrauma. Initial cardiac arrhythmics were diagnosed in 16.6% of the primarily treated patients. Thirty per cent of our patients had neurological complications such as peripheral paresis, tetraplegia and paraplegia, 20.7% of these caused solely by the electric current.

  20. Voltage-dependent gating in a "voltage sensor-less" ion channel.

    Directory of Open Access Journals (Sweden)

    Harley T Kurata

    2010-02-01

    Full Text Available The voltage sensitivity of voltage-gated cation channels is primarily attributed to conformational changes of a four transmembrane segment voltage-sensing domain, conserved across many levels of biological complexity. We have identified a remarkable point mutation that confers significant voltage dependence to Kir6.2, a ligand-gated channel that lacks any canonical voltage-sensing domain. Similar to voltage-dependent Kv channels, the Kir6.2[L157E] mutant exhibits time-dependent activation upon membrane depolarization, resulting in an outwardly rectifying current-voltage relationship. This voltage dependence is convergent with the intrinsic ligand-dependent gating mechanisms of Kir6.2, since increasing the membrane PIP2 content saturates Po and eliminates voltage dependence, whereas voltage activation is more dramatic when channel Po is reduced by application of ATP or poly-lysine. These experiments thus demonstrate an inherent voltage dependence of gating in a "ligand-gated" K+ channel, and thereby provide a new view of voltage-dependent gating mechanisms in ion channels. Most interestingly, the voltage- and ligand-dependent gating of Kir6.2[L157E] is highly sensitive to intracellular [K+], indicating an interaction between ion permeation and gating. While these two key features of channel function are classically dealt with separately, the results provide a framework for understanding their interaction, which is likely to be a general, if latent, feature of the superfamily of cation channels.

  1. The sensing mechanism of N-doped SWCNTs toward SF6 decomposition products: A first-principle study

    Science.gov (United States)

    Gui, Yingang; Tang, Chao; Zhou, Qu; Xu, Lingna; Zhao, Zhongyong; Zhang, Xiaoxing

    2018-05-01

    In order to monitor the insulation status of SF6-insulated equipment on-line, SOF2 and SO2F2, two typical decomposition products of SF6 under electric discharge condition, are chosen as the target gases to evaluate the type and severity of discharge. In this work, single N atom doping method is adopted to improve the gas sensitivity of single wall carbon nanotubes to SOF2 and SO2F2. Single and double gas molecules adsorptions are considered to completely analyze the adsorption properties of N-doped single wall carbon nanotubes. Calculation results show that N atom doping enhances the surface activity of carbon nanotubes. When gas molecules physically adsorbed on N-doped single wall carbon nanotubes, the weak interaction between gas molecules and N-doped single wall carbon nanotubes nearly not changes the electrical property according to analysis of the density of states and molecular orbitals. While the chemisorption between gas molecules and N-doped single wall carbon nanotubes distinctly decreases the conductivity of adsorption system.

  2. High-voltage pulsed generator for dynamic fragmentation of rocks.

    Science.gov (United States)

    Kovalchuk, B M; Kharlov, A V; Vizir, V A; Kumpyak, V V; Zorin, V B; Kiselev, V N

    2010-10-01

    A portable high-voltage (HV) pulsed generator has been designed for rock fragmentation experiments. The generator can be used also for other technological applications. The installation consists of low voltage block, HV block, coaxial transmission line, fragmentation chamber, and control system block. Low voltage block of the generator, consisting of a primary capacitor bank (300 μF) and a thyristor switch, stores pulse energy and transfers it to the HV block. The primary capacitor bank stores energy of 600 J at the maximum charging voltage of 2 kV. HV block includes HV pulsed step up transformer, HV capacitive storage, and two electrode gas switch. The following technical parameters of the generator were achieved: output voltage up to 300 kV, voltage rise time of ∼50 ns, current amplitude of ∼6 kA with the 40 Ω active load, and ∼20 kA in a rock fragmentation regime (with discharge in a rock-water mixture). Typical operation regime is a burst of 1000 pulses with a frequency of 10 Hz. The operation process can be controlled within a wide range of parameters. The entire installation (generator, transmission line, treatment chamber, and measuring probes) is designed like a continuous Faraday's cage (complete shielding) to exclude external electromagnetic perturbations.

  3. High-voltage pulsed generator for dynamic fragmentation of rocks

    Science.gov (United States)

    Kovalchuk, B. M.; Kharlov, A. V.; Vizir, V. A.; Kumpyak, V. V.; Zorin, V. B.; Kiselev, V. N.

    2010-10-01

    A portable high-voltage (HV) pulsed generator has been designed for rock fragmentation experiments. The generator can be used also for other technological applications. The installation consists of low voltage block, HV block, coaxial transmission line, fragmentation chamber, and control system block. Low voltage block of the generator, consisting of a primary capacitor bank (300 μF) and a thyristor switch, stores pulse energy and transfers it to the HV block. The primary capacitor bank stores energy of 600 J at the maximum charging voltage of 2 kV. HV block includes HV pulsed step up transformer, HV capacitive storage, and two electrode gas switch. The following technical parameters of the generator were achieved: output voltage up to 300 kV, voltage rise time of ˜50 ns, current amplitude of ˜6 kA with the 40 Ω active load, and ˜20 kA in a rock fragmentation regime (with discharge in a rock-water mixture). Typical operation regime is a burst of 1000 pulses with a frequency of 10 Hz. The operation process can be controlled within a wide range of parameters. The entire installation (generator, transmission line, treatment chamber, and measuring probes) is designed like a continuous Faraday's cage (complete shielding) to exclude external electromagnetic perturbations.

  4. Physicochemical assessment criteria for high-voltage pulse capacitors

    Energy Technology Data Exchange (ETDEWEB)

    Darian, L. A., E-mail: LDarian@rambler.ru; Lam, L. Kh. [National Research University, Moscow Power Engineering Institute (Russian Federation)

    2016-12-15

    In the paper, the applicability of decomposition products of internal insulation of high-voltage pulse capacitors is considered (aging is the reason for decomposition products of internal insulation). Decomposition products of internal insulation of high-voltage pulse capacitors can be used to evaluate their quality when in operation and in service. There have been three generations of markers of aging of insulation as in the case with power transformers. The area of applicability of markers of aging of insulation for power transformers has been studied and the area can be extended to high-voltage pulse capacitors. The research reveals that there is a correlation between the components and quantities of markers of aging of the first generation (gaseous decomposition products of insulation) dissolved in insulating liquid and the remaining life of high-voltage pulse capacitors. The application of markers of aging to evaluate the remaining service life of high-voltage pulse capacitor is a promising direction of research, because the design of high-voltage pulse capacitors keeps stability of markers of aging of insulation in high-voltage pulse capacitors. It is necessary to continue gathering statistical data concerning development of markers of aging of the first generation. One should also carry out research aimed at estimation of the remaining life of capacitors using markers of the second and the third generation.

  5. Physicochemical assessment criteria for high-voltage pulse capacitors

    International Nuclear Information System (INIS)

    Darian, L. A.; Lam, L. Kh.

    2016-01-01

    In the paper, the applicability of decomposition products of internal insulation of high-voltage pulse capacitors is considered (aging is the reason for decomposition products of internal insulation). Decomposition products of internal insulation of high-voltage pulse capacitors can be used to evaluate their quality when in operation and in service. There have been three generations of markers of aging of insulation as in the case with power transformers. The area of applicability of markers of aging of insulation for power transformers has been studied and the area can be extended to high-voltage pulse capacitors. The research reveals that there is a correlation between the components and quantities of markers of aging of the first generation (gaseous decomposition products of insulation) dissolved in insulating liquid and the remaining life of high-voltage pulse capacitors. The application of markers of aging to evaluate the remaining service life of high-voltage pulse capacitor is a promising direction of research, because the design of high-voltage pulse capacitors keeps stability of markers of aging of insulation in high-voltage pulse capacitors. It is necessary to continue gathering statistical data concerning development of markers of aging of the first generation. One should also carry out research aimed at estimation of the remaining life of capacitors using markers of the second and the third generation.

  6. Myocarditis in auto-immune or auto-inflammatory diseases.

    Science.gov (United States)

    Comarmond, Cloé; Cacoub, Patrice

    2017-08-01

    Myocarditis is a major cause of heart disease in young patients and a common precursor of heart failure due to dilated cardiomyopathy. Some auto-immune and/or auto-inflammatory diseases may be accompanied by myocarditis, such as sarcoidosis, Behçet's disease, eosinophilic granulomatosis with polyangiitis, myositis, and systemic lupus erythematosus. However, data concerning myocarditis in such auto-immune and/or auto-inflammatory diseases are sparse. New therapeutic strategies should better target the modulation of the immune system, depending on the phase of the disease and the type of underlying auto-immune and/or auto-inflammatory disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Time isolation high-voltage impulse generator

    International Nuclear Information System (INIS)

    Chodorow, A.M.

    1975-01-01

    Lewis' high-voltage impulse generator is analyzed in greater detail, demonstrating that voltage between adjacent nodes can be equalized by proper selection of parasitic impedances. This permits improved TEM mode propagation to a matched load, with more faithful source waveform preservation

  8. Superconcentrated electrolytes for a high-voltage lithium-ion battery

    Science.gov (United States)

    Wang, Jianhui; Yamada, Yuki; Sodeyama, Keitaro; Chiang, Ching Hua; Tateyama, Yoshitaka; Yamada, Atsuo

    2016-01-01

    Finding a viable electrolyte for next-generation 5 V-class lithium-ion batteries is of primary importance. A long-standing obstacle has been metal-ion dissolution at high voltages. The LiPF6 salt in conventional electrolytes is chemically unstable, which accelerates transition metal dissolution of the electrode material, yet beneficially suppresses oxidative dissolution of the aluminium current collector; replacing LiPF6 with more stable lithium salts may diminish transition metal dissolution but unfortunately encounters severe aluminium oxidation. Here we report an electrolyte design that can solve this dilemma. By mixing a stable lithium salt LiN(SO2F)2 with dimethyl carbonate solvent at extremely high concentrations, we obtain an unusual liquid showing a three-dimensional network of anions and solvent molecules that coordinate strongly to Li+ ions. This simple formulation of superconcentrated LiN(SO2F)2/dimethyl carbonate electrolyte inhibits the dissolution of both aluminium and transition metal at around 5 V, and realizes a high-voltage LiNi0.5Mn1.5O4/graphite battery that exhibits excellent cycling durability, high rate capability and enhanced safety. PMID:27354162

  9. Bimodal cell death induced by high radiation doses in the radioresistant sf9 insect cell line

    International Nuclear Information System (INIS)

    Chandna, S.

    2003-01-01

    Full text: This study was conducted to investigate the mode(s) of cell death induced by high radiation doses in the highly radioresistant Sf9 insect ovarian cell line. Methods: Cells were exposed to γ-radiation doses 200Gy and 500Gy, harvested at various time intervals (6h-72h) following irradiation, and subjected to cell morphology assay, DNA agarose gel electrophoresis, single cell gel electrophoresis (SCGE; comet assay) and Annexin-V labeling for the detection of membrane phosphatidylserine externalization. Cell morphology was assessed in cells entrapped and fixed in agarose gel directly from the cell suspension, thus preventing the possible loss of fragments/ apoptotic bodies. Surviving fraction of Sf9 cells was 0.01 at 200Gy and 98%) undergoing extensive DNA fragmentation at 500Gy, whereas the frequency of cells with DNA fragmentation was considerably less (∼12%) at 200Gy. Conclusions: While the mode of cell death at 200Gy seems to be different from typical apoptosis, a dose of 500Gy induced bimodal cell death, with typical apoptotic as well as the atypical cell death observed at 200Gy

  10. [PSYCHOTHERAPEUTIC INTERVENTIONS IN PATIENTS WITH AUTO-AGGRESSIVE BEHAVIOR DURING THE FIRST PSYCHOTIC EPISODE].

    Science.gov (United States)

    Mudrenko, I; Potapov, A; Sotnikov, D; Kolenko, O; Kmyta, A

    2017-09-01

    In this article the formation of psychopathological predictors auto-aggressive behavior in patients with a first psychotic episode were identified, which became "targets" in the framework of a comprehensive emergency suicide assistance to conduct the crisis psychotherapy. The work was done on the basis of the Sumy regional psychoneurologic dispensary, where 100 patients with a first psychotic episode were examined: 52 of them (core group) had suicidal symptoms and 48 (control group) had not. According to the test results of severity of auto-aggressive predictors (pre-suicidal syndrome) to clinicopsychopathological predictors of auto-aggressive behavior include: the narrowing of the cognitive function (p≤0,001), the avoidance of interpersonal contact (r≤0,001), the presence of affective (p≤0,001) and vegetative (p≤0,01) violations, the autoaggression of moderate severity (p≤0,001) and impulsivity (p≤0,001). Patients of the core group with the auto-aggressive behavior (n=58) completed a course of a crisis psychotherapy comprising the stages of crisis support, crisis intervention and increase the adaptation layer. After a psychotherapy course levels of aggression (6,45±0,41), auto-aggression (of 9,68±0,67), disorders in the affective sphere (18,58±0,66) and impulsivity (of 4,23±0,30) decreased, which was manifested in increasing tolerance to emotional stress factors, control over their emotions and reduce their affective valence (p≤0,001). The expansion of interpersonal interaction, the increase of patients social activity, the blood relationships establishment (of 9,23±0,40) was observed.

  11. Detecting Faults In High-Voltage Transformers

    Science.gov (United States)

    Blow, Raymond K.

    1988-01-01

    Simple fixture quickly shows whether high-voltage transformer has excessive voids in dielectric materials and whether high-voltage lead wires too close to transformer case. Fixture is "go/no-go" indicator; corona appears if transformer contains such faults. Nests in wire mesh supported by cap of clear epoxy. If transformer has defects, blue glow of corona appears in mesh and is seen through cap.

  12. Development of intense high-energy noble gas ion beams from in-terminal ion injector of tandem accelerator using an ECR ion source

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, M., E-mail: matsuda.makoto@jaea.go.jp [Japan Atomic Energy Agency (JAEA), Tokai Research and Development Center, 2-4 Shirakata-shirane, Tokai, Naka, Ibaraki 319-1195 (Japan); Nakanoya, T.; Hanashima, S.; Takeuchi, S. [Japan Atomic Energy Agency (JAEA), Tokai Research and Development Center, 2-4 Shirakata-shirane, Tokai, Naka, Ibaraki 319-1195 (Japan)

    2011-10-21

    An ECRIS-based heavy ion injector was constructed in the high-voltage terminal of JAEA-Tokai Tandem Accelerator to develop new beam species of highly charged noble gas ions. This work was associated with a lot of development to operate the ion source on the 20UR Pelletron high voltage terminal in high pressure SF{sub 6} gas environment. Highly charged ions of N, O, Ne, Ar, Kr and Xe have been accelerated satisfactorily. Operating data integrated during many years long beam delivery service are summarized.

  13. AutoCAD 2008 and AutoCAD LT 2008 Bible

    CERN Document Server

    Finkelstein, Ellen

    2011-01-01

    "Whether you're new to AutoCAD or a veteran, you will undoubtedly find this book to be an excellent resource."-- Abhi Singh, AutoCAD Product Manager, Autodesk, Inc.Here's the book that makes AutoCAD approachableEven the people at Autodesk look to Ellen Finkelstein for AutoCAD training, so who better to teach you about AutoCAD 2008? This comprehensive guide brings veterans up to speed on AutoCAD updates and takes novices from the basics to programming in AutoLISP(r) and VBA. Every feature is covered in a logical order, and with the Quick Start chapter, you'll be creating drawings on your very f

  14. Nested high voltage generator/particle accelerator

    International Nuclear Information System (INIS)

    Adler, R.J.

    1992-01-01

    This patent describes a modular high voltage particle accelerator having an emission axis and an emission end, the accelerator. It comprises: a plurality of high voltage generators in nested adjacency to form a nested stack, each the generator comprising a cup-like housing having a base and a tubular sleeve extending from the base, a primary transformer winding encircling the nested stack; a secondary transformer winding between each adjacent pair of housings, magnetically linked to the primary transformer winding through the gaps; a power supply respective to each of the secondary windings converting alternating voltage from its respective secondary winding to d.c. voltage, the housings at the emission end forming a hollow throat for particle acceleration, a vacuum seal at the emission end of the throat which enables the throat to be evacuated; a particle source in the thrond power means to energize the primary transformer winding

  15. Discussion - a high voltage DC generator

    International Nuclear Information System (INIS)

    Bhagwat, P.V.; Singh, Jagir; Hattangadi, V.A.

    1993-01-01

    One of the requirements for a high power ion source is a high voltage, high current DC generator. The high voltage, high current generator, DISCATRON, presently under development in our laboratory is a rotating disc type electrostatic generator similar in design to the one reported by A. Isoya et al. (1985). It is compact and rugged electrostatic DC generator based on the principle of induction charging by pellet chains used in the pelletron accelerator. It is, basically, a constant-current device with little stored energy, so that, in case of a breakdown, damage to the equipment connected to the output terminals is minimal. Since the present generator is only a proto-type, meant for a study of the practical difficulties that would be encountered in its manufacture, the output voltage and current specified has been kept quite modest viz., 300 kV at 500 μA, maximum. Some results of the preliminary tests carried out with this generator are described. (author). 4 figs

  16. High voltage investigations for ITER coils

    International Nuclear Information System (INIS)

    Fink, S.; Fietz, W.H.

    2006-01-01

    The superconducting ITER magnets will be excited with high voltage during operation and fast discharge. Because the coils are complex systems the internal voltage distribution can differ to a large extent from the ideal linear voltage distribution. In case of fast excitations internal voltages between conductor and radial plate of a TF coil can be even higher than the terminal voltage of 3.5 kV to ground which appears during a fast discharge without a fault. Hence the determination of the transient voltage distribution is important for a proper insulation co-ordination and will provide a necessary basis for the verification of the individual insulation design and the choice of test voltages and waveforms. Especially the extent of internal overvoltages in case of failures, e. g. malfunction of discharge units and / or arcing is of special interest. Transient calculations for the ITER TF coil system have been performed for fast discharge and fault scenarios to define test voltages for ITER TF. The conductor and radial plate insulation of the ITER TF Model Coil were exposed at room temperature to test voltages derived from the results from these calculations. Breakdown appeared during the highest AC voltage step. A fault scenario for the TF fast discharge system is presented where one fault triggers a second fault, leading to considerable voltage stress. In addition a FEM model of Poloidal Field Coil 3 for the determination of the parameters of a detailed network model is presented in order to prepare detailed investigations of the transient voltage behaviour of the PF coils. (author)

  17. The "11K" gene family members sf68, sf95 and sf138 modulate transmissibility and insecticidal properties of Spodoptera frugiperda multiple nucleopolyhedrovirus.

    Science.gov (United States)

    Beperet, Inés; Simón, Oihane; Williams, Trevor; López-Ferber, Miguel; Caballero, Primitivo

    2015-05-01

    The "11K" gene family is notable for having homologs in both baculoviruses and entomopoxviruses and is classified as either type 145 or type 150, according to their similarity with the ac145 or ac150 genes of Autographa californica multiple nucleopolyhedrovirus (AcMNPV). One homolog of ac145 (sf138) and two homologs of ac150 (sf68 and sf95) are present in Spodoptera frugiperda multiple nucleopolyhedrovirus (SfMNPV). Recombinant bacmids lacking sf68, sf95 or sf138 (Sf68null, Sf95null and Sf138null, respectively) and the respective repair bacmids were generated from a bacmid comprising the complete virus genome. Occlusion bodies (OBs) of the Sf138null virus were ∼15-fold less orally infective to insects, which was attributed to a 100-fold reduction in ODV infectious titer. Inoculation of insects with Sf138null OBs in mixtures with an optical brightener failed to restore the pathogenicity of Sf138null OBs to that of the parental virus, indicating that the effects of sf138 deletion on OB pathogenicity were unlikely to involve an interaction with the gut peritrophic matrix. In contrast, deletion of sf68 and sf95 resulted in a slower speed-of-kill by 9h, and a concurrent increase in the yield of OBs. Phylogenetic analysis indicated that sf68 and sf95 were not generated after a duplication event of an ancestral gene homologous to the ac150 gene. We conclude that type 145 genes modulate the primary infection process of the virus, whereas type 150 genes appear to have a role in spreading systemic infection within the insect. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. High Voltage in Noble Liquids for High Energy Physics

    Energy Technology Data Exchange (ETDEWEB)

    Rebel, B. [Fermilab; Bernard, E. [Yale U.; Faham, C. H. [LBL, Berkeley; Ito, T. M. [Los Alamos; Lundberg, B. [Maryland U.; Messina, M. [Columbia U.; Monrabal, F. [Valencia U., IFIC; Pereverzev, S. P. [LLNL, Livermore; Resnati, F. [Zurich, ETH; Rowson, P. C. [SLAC; Soderberg, M. [Fermilab; Strauss, T. [Bern U.; Tomas, A. [Imperial Coll., London; Va' vra, J. [SLAC; Wang, H. [UCLA

    2014-08-22

    A workshop was held at Fermilab November 8-9, 2013 to discuss the challenges of using high voltage in noble liquids. The participants spanned the fields of neutrino, dark matter, and electric dipole moment physics. All presentations at the workshop were made in plenary sessions. This document summarizes the experiences and lessons learned from experiments in these fields at developing high voltage systems in noble liquids.

  19. Auto-regenerative TL dating with zircon inclusions from fired materials

    International Nuclear Information System (INIS)

    Templer, R.H.; Smith, B.W.

    1988-01-01

    In this paper it is shown that it is possible to date fired material using zircon inclusions. The effects of zoning and anomalous fading are overcome using an auto-regenerative dating procedure. The high radioactivity of the grains gives a measurable self-induced TL (thermoluminescence) signal within a few months. Comparison of this ''auto-regenerated'' TL with the natural TL (which has accumulated since the firing) yields the age of the material. A sensitive TL reader capable of recording the auto-regenerated signal after 6 months is also described, and the results of age determinations on a number of known age samples are presented. (author)

  20. High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs

    Science.gov (United States)

    Shimer, Daniel W.; Lange, Arnold C.

    1995-01-01

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

  1. High voltage dc--dc converter with dynamic voltage regulation and decoupling during load-generated arcs

    Science.gov (United States)

    Shimer, D.W.; Lange, A.C.

    1995-05-23

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.

  2. Avulsion research using flume experiments and highly accurate and temporal-rich SfM datasets

    Science.gov (United States)

    Javernick, L.; Bertoldi, W.; Vitti, A.

    2017-12-01

    SfM's ability to produce high-quality, large-scale digital elevation models (DEMs) of complicated and rapidly evolving systems has made it a valuable technique for low-budget researchers and practitioners. While SfM has provided valuable datasets that capture single-flood event DEMs, there is an increasing scientific need to capture higher temporal resolution datasets that can quantify the evolutionary processes instead of pre- and post-flood snapshots. However, flood events' dangerous field conditions and image matching challenges (e.g. wind, rain) prevent quality SfM-image acquisition. Conversely, flume experiments offer opportunities to document flood events, but achieving consistent and accurate DEMs to detect subtle changes in dry and inundated areas remains a challenge for SfM (e.g. parabolic error signatures).This research aimed at investigating the impact of naturally occurring and manipulated avulsions on braided river morphology and on the encroachment of floodplain vegetation, using laboratory experiments. This required DEMs with millimeter accuracy and precision and at a temporal resolution to capture the processes. SfM was chosen as it offered the most practical method. Through redundant local network design and a meticulous ground control point (GCP) survey with a Leica Total Station in red laser configuration (reported 2 mm accuracy), the SfM residual errors compared to separate ground truthing data produced mean errors of 1.5 mm (accuracy) and standard deviations of 1.4 mm (precision) without parabolic error signatures. Lighting conditions in the flume were limited to uniform, oblique, and filtered LED strips, which removed glint and thus improved bed elevation mean errors to 4 mm, but errors were further reduced by means of an open source software for refraction correction. The obtained datasets have provided the ability to quantify how small flood events with avulsion can have similar morphologic and vegetation impacts as large flood events

  3. Séminaire de l'enseignement technique : Forum AutoCAD 2006 et AutoCAD Mechanical 2006 - French version only

    CERN Multimedia

    Davide Vitè

    2005-01-01

    Jeudi 17 novembre 2005 de 14:30 à 16:30 - Training Centre Auditorium Forum AutoCAD 2006 et AutoCAD Mechanical 2006 CADSCHOOL, CH-1207 GENEVE, Suisse Ce nouveau séminaire de l'Enseignement technique, organisé en forme de forum et en collabora- tion avec TS-MME et notre entreprise partenaire en formation, sera consacré à la présentation de la nouvelle version d'AutoCAD, AutoCAD 2006 et AutoCAD Mechanical 2006, disponible au CERN. Au programme : Présentation d'AutoCAD Mechanical 2006 Améliorations par rapport à AutoCAD Mechanical 6 Power Pack Questions - Réponses Langue: Français. Séminaire libre, sans inscription. Organisateurs: Manfred Mayer / TS-MME / 74499 ; Davide Vitè / HR-PMD / 75141 Pour plus d'information, veuillez SVP visiter les pages des Séminaires de l'Enseignement Technique à l'adresse http://www.cern.ch/TechnicalTraining/special/TTseminars.asp . ENSEIGNEMENT TECHNIQUE TECHNICAL TRAINING technical.training@cern.ch

  4. Properties and etching rates of negative ions in inductively coupled plasmas and dc discharges produced in Ar/SF6

    International Nuclear Information System (INIS)

    Draghici, M.; Stamate, E.

    2010-01-01

    Negative ion production is investigated in a chamber with transversal magnetic filter operated in dc or inductively coupled plasma (ICP) modes in Ar/SF 6 gas mixtures. Plasma parameters are evaluated by mass spectrometry and Langmuir probe for different discharge conditions. The density ratio of negative ion to electron exceeded 300 in dc mode while it was below 100 in the ICP mode. The possibility to apply a large positive bias to an electrode without affecting the plasma potential and the transition from a negative sheath to anodic glow are also investigated. The etching rates by positive and negative ions are evaluated on silicon substrate for different Ar/SF 6 gas ratios. The etching rate by negative ions was with less than 5% smaller than that by positive ions.

  5. Properties and etching rates of negative ions in inductively coupled plasmas and dc discharges produced in Ar/SF6

    DEFF Research Database (Denmark)

    Draghici, Mihai; Stamate, Eugen

    2010-01-01

    of negative ion to electron exceeded 300 in dc mode while it was below 100 in the ICP mode. The possibility to apply a large positive bias to an electrode without affecting the plasma potential and the transition from a negative sheath to anodic glow are also investigated. The etching rates by positive...... and negative ions are evaluated on silicon substrate for different Ar/SF6 gas ratios. The etching rate by negative ions was with less than 5% smaller than that by positive ions.......Negative ion production is investigated in a chamber with transversal magnetic filter operated in dc or inductively coupled plasma (ICP) modes in Ar/SF6 gas mixtures. Plasma parameters are evaluated by mass spectrometry and Langmuir probe for different discharge conditions. The density ratio...

  6. High voltage pulse generator. [Patent application

    Science.gov (United States)

    Fasching, G.E.

    1975-06-12

    An improved high-voltage pulse generator is described which is especially useful in ultrasonic testing of rock core samples. An N number of capacitors are charged in parallel to V volts and at the proper instance are coupled in series to produce a high-voltage pulse of N times V volts. Rapid switching of the capacitors from the paralleled charging configuration to the series discharging configuration is accomplished by using silicon-controlled rectifiers which are chain self-triggered following the initial triggering of the first rectifier connected between the first and second capacitors. A timing and triggering circuit is provided to properly synchronize triggering pulses to the first SCR at a time when the charging voltage is not being applied to the parallel-connected charging capacitors. The output voltage can be readily increased by adding additional charging networks. The circuit allows the peak level of the output to be easily varied over a wide range by using a variable autotransformer in the charging circuit.

  7. Application of multiple tracers (SF6 and chloride) to identify the transport by characteristics of contaminant at two separate contaminated sites

    Science.gov (United States)

    Lee, K. K.; Lee, S. S.; Kim, H. H.; Koh, E. H.; Kim, M. O.; Lee, K.; Kim, H. J.

    2016-12-01

    Multiple tracers were applied for source and pathway detection at two different sites. CO2 gas injected in the subsurface for a shallow-depth CO2 injection and leak test can be regarded as a potential contaminant source. Therefore, it is necessary to identify the migration pattern of CO2 gas. Also, at a DNAPL contaminated site, it is important to figure out the characteristics of plume evolution from the source zone. In this study, multiple tracers (SF6 and chloride) were used to evaluate the applicability of volatile and non-volatile tracers and to identify the characteristics of contaminant transport at each CO2 injection and leak test site and DNAPL contaminated site. Firstly, at the CO2 test site, multiple tracers were used to perform the single well push-drift-pull tracer test at total 3 specific depth zones. As results of tests, volatile and non-volatile tracers showed different mass recovery percentage. Most of chloride mass was recovered but less than half of SF6 mass was recovered due to volatile property. This means that only gaseous SF6 leak out to unsaturated zone. However, breakthrough curves of both tracers indicated similar peak time, effective porosity, and regional groundwater velocity. Also, at both contaminated sites, natural gradient tracer tests were performed with multiple tracers. With the results of natural gradient tracer test, it was possible to confirm the applicability of multiple tracers and to understand the contaminant transport in highly heterogeneous aquifer systems through the long-term monitoring of tracers. Acknowledgement: financial support was provided by the R&D Project on Environmental Management of Geologic CO2 Storage)" from the KEITI (Project Number: 2014001810003) and Korea Ministry of Environment as "The GAIA project (2014000540010)".

  8. Auto-ignition of lubricating oil working at high pressures in a compressor for an air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chul Jin; Choi, Hyo Hyun [Department of Mechanical Engineering, Sejong University, Seoul 143-747 (Korea, Republic of); Sohn, Chae Hoon, E-mail: chsohn@sejong.ac.kr [Department of Mechanical Engineering, Sejong University, Seoul 143-747 (Korea, Republic of)

    2011-01-15

    Auto-ignition of lubricating oil working in a compressor for an air conditioner is studied experimentally. The adopted lubricating oil is an unknown mixture with multi-components and known to have flash point temperature of 170 deg. C. First, its auto-ignition temperature is measured 365 deg. C at atmospheric pressure. The lubricating oil works under high-pressure condition up to 30 atm and it is heated and cooled down repeatedly. Accordingly, auto-ignition temperatures or flammable limits of lubricating oil are required at high pressures with respect to fire safety. Because there is not a standard test method for the purpose, a new ignition-test method is proposed in this study and thereby, auto-ignition temperatures are measured over the pressure range below 30 atm. The measured temperatures range from 215 deg. C to 255 deg. C and they strongly depend on pressure of gas mixture consisting of oil vapor, nitrogen, and oxygen. They are close to flash point temperature and the lubricating oil can be hazardous when it works for high-pressure operating condition and abundant air flows into a compressor.

  9. Auto-ignition of lubricating oil working at high pressures in a compressor for an air conditioner

    International Nuclear Information System (INIS)

    Kim, Chul Jin; Choi, Hyo Hyun; Sohn, Chae Hoon

    2011-01-01

    Auto-ignition of lubricating oil working in a compressor for an air conditioner is studied experimentally. The adopted lubricating oil is an unknown mixture with multi-components and known to have flash point temperature of 170 deg. C. First, its auto-ignition temperature is measured 365 deg. C at atmospheric pressure. The lubricating oil works under high-pressure condition up to 30 atm and it is heated and cooled down repeatedly. Accordingly, auto-ignition temperatures or flammable limits of lubricating oil are required at high pressures with respect to fire safety. Because there is not a standard test method for the purpose, a new ignition-test method is proposed in this study and thereby, auto-ignition temperatures are measured over the pressure range below 30 atm. The measured temperatures range from 215 deg. C to 255 deg. C and they strongly depend on pressure of gas mixture consisting of oil vapor, nitrogen, and oxygen. They are close to flash point temperature and the lubricating oil can be hazardous when it works for high-pressure operating condition and abundant air flows into a compressor.

  10. A high-speed bioelectrical impedance spectroscopy system based on the digital auto-balancing bridge method

    International Nuclear Information System (INIS)

    Li, Nan; Xu, Hui; Zhou, Zhou; Wang, Wei; Qiao, Guofeng; Li, David D-U

    2013-01-01

    A novel bioelectrical impedance spectroscopy system based on the digital auto-balancing bridge method improved from the conventional analogue auto-balancing method is presented for bioelectrical impedance measurements. The hardware of the proposed system consists of a reference source, a null detector, a variable source, a field programmable gate array, a clock generator, a flash and a USB controller. Software implemented in the field programmable gate array includes three major blocks: clock management, peripheral control and digital signal processing. The principle and realization of the least-mean-squares-based digital auto-balancing algorithm is introduced in detail. The performances of our system were examined by comparing with a commercial impedance analyzer. The results reveal that the proposed system has high speed (less than 3.5 ms per measurement) and high accuracy in the frequency range of 1 kHz–10 MHz. Compared with the commercial instrument based on the traditional analogue auto-balancing method, our system shows advantages in measurement speed, compactness and flexibility, making it suitable for various bioelectrical impedance measurement applications. (paper)

  11. Abortive replication of Bombyx mori nucleopolyhedrovirus in Sf9 and High Five cells: Defective nuclear transport of the virions

    International Nuclear Information System (INIS)

    Katou, Yasuhiro; Ikeda, Motoko; Kobayashi, Michihiro

    2006-01-01

    Despite close genetic relationship, Bombyx mori nucleopolyhedrovirus (BmNPV) and Autographa californica multicapsid NPV (AcMNPV) display a distinct host range property. Here, BmNPV replication was examined in Sf9 and High Five cells that were nonproductive for BmNPV infection but supported high titers of AcMNPV replication. Recombinant BmNPV, vBm/gfp/lac, containing bm-ie1 promoter-driven egfp showed that few Sf9 and High Five cells infected with vBm/gfp/lac expressed EGFP, while large proportion of EGFP-expressing cells was observed when transfected with vBm/gfp/lac DNA. Immunocytochemical analysis showed that BmNPV was not imported into the nucleus of these two cell lines, while recombinant BmNPV, vBmΔ64/ac-gp64 possessing AcMNPV gp64 was imported into the nucleus, yielding progeny virions in High Five cells, but not Sf9 cells. These results indicate that the defective nuclear import of infected virions due to insufficient BmNPV GP64 function is involved in the restricted BmNPV replication in Sf9 and High Five cells

  12. The Mounting process and dielectric tests of the Parque Caballero armored substation in SF6(220 Kv); Montaje y pruebas dielectricas de la estacion blindada en gas SF6 (220 kV) 'Parque Caballero'

    Energy Technology Data Exchange (ETDEWEB)

    Decoud, Carlos; Bobadilla, Alberto [ANDE - Administracion Nacional de Electricidad, Assuncion (Paraguay)

    2001-07-01

    This document approaches the aspects referring to the mounting and also dielectric tests for the Parque Caballero armored substation in SF6. This type of installation represents a innovation regarding substations in urban centres. The most relevant items in relation to the mounting process are shown in a summarized way, as well as the aspects related to dielectric tests executed during the substation commissioning.

  13. AutoCAD 2014 and AutoCAD LT 2014

    CERN Document Server

    Gladfelter, Donnie

    2013-01-01

    A step-by-step tutorial introduction to AutoCAD As the only book to teach AutoCAD using a continuous tutorial which allows you to follow along sequentially or jump in at any exercise by downloading the drawing files, this Autodesk Official Press book is ideal for the AutoCAD novice. Industry expert and AutoCAD guru Donnie Gladfelter walks you through the powerful features of AutoCAD, provides you with a solid foundation of the basics, and shares the latest industry standards and techniques. The hands-on tutorial project inspired by real-world workflows that runs throughout the book

  14. Thermodynamic and transport properties of two-temperature SF6 plasmas

    International Nuclear Information System (INIS)

    Wang Weizong; Rong Mingzhe; Wu Yi; Spencer, Joseph W.; Yan, Joseph D.; Mei, DanHua

    2012-01-01

    This paper deals with thermodynamic and transport properties of SF 6 plasmas in a two-temperature model for both thermal equilibrium and non-equilibrium conditions. The species composition and thermodynamic properties are numerically determined using the two-temperature Saha equation and Guldberg-Waage equation according to deviation of van de Sanden et al. Transport properties including diffusion coefficient, viscosity, thermal conductivity, and electrical conductivity are calculated with most recent collision interaction potentials by adopting Devoto’s electron and heavy particle decoupling approach but expanded to the third-order approximation (second-order for viscosity) in the frame of Chapman–Enskog method. The results are computed for various values of pressures from 0.1 atm to 10 atm and ratios of the electron temperature to the heavy particle temperature from 1 to 20 with electron temperature range from 300 to 40 000 K. In the local thermodynamic equilibrium regime, results are compared with available results of previously published studies.

  15. Dating of young groundwater using tritium and gaseous tracers (SF6, SF5CF3, CFC-12, H-1301): case study from southern Poland

    Science.gov (United States)

    Rozanski, Kazimierz; Bartyzel, Jakub; Dulinski, Marek; Kuc, Tadeusz; Sliwka, Ireneusz; Mochalski, Pawel; Kania, Jaroslaw; Witczak, Stanislaw

    2013-04-01

    was employed. Apart of well-established tracers such as SF6 and CFC-12, also other trace gases present in the atmosphere (SF5CF3 and H-1301) were tested as age indicators of young groundwater. Time series of tracer concentrations in the sampled boreholes were interpreted with the aid of lumped-parameter models. In parallel, the arrival times of tracers to the selected wells were calculated with the aid of 3D flow and transport model available for the studied groundwater system and compared with the RTD functions obtained from lumped-parameter modeling. Acknowledgements. Partial financial support of this work through GENESIS project (http:/www.thegenesisproject.eu) funded by the European Commission 7FP contract 226536 and through the funds from the Polish Ministry of Science and High Education (projects Nr. N N525 362637 and 11.11.220.01) is kindly acknowledged.

  16. 76 FR 72203 - Voltage Coordination on High Voltage Grids; Notice of Reliability Workshop Agenda

    Science.gov (United States)

    2011-11-22

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD12-5-000] Voltage Coordination on High Voltage Grids; Notice of Reliability Workshop Agenda As announced in the Notice of Staff..., from 9 a.m. to 4:30 p.m. to explore the interaction between voltage control, reliability, and economic...

  17. Improvements on high voltage capacity and high temperature performances of Si-based Schottky potential barrier diode

    International Nuclear Information System (INIS)

    Wang Yongshun; Rui Li; Adnan Ghaffar; Wang Zaixing; Liu Chunjuan

    2015-01-01

    In order to improve the reverse voltage capacity and low junction temperature characteristics of the traditional silicon-based Schottky diode, a Schottky diode with high reverse voltage capacity and high junction temperature was fabricated using ion implantation, NiPt60 sputtering, silicide-forming and other major technologies on an N-type silicon epitaxial layer of 10.6–11.4 μm and (2.2–2.4) × 10 15 cm −3 doping concentration. The measurement results show that the junction temperature of the Schottky diode fabricated can reach 175 °C, that is 50 °C higher than that of the traditional one; the reverse voltage capacity V R can reach 112 V, that is 80 V higher than that of the traditional one; the leakage current is only 2 μA and the forward conduction voltage drop is V F = 0.71 V at forward current I F = 3 A. (semiconductor devices)

  18. High Voltage GaN Schottky Rectifiers

    Energy Technology Data Exchange (ETDEWEB)

    CAO,X.A.; CHO,H.; CHU,S.N.G.; CHUO,C.-C.; CHYI,J.-I.; DANG,G.T.; HAN,JUNG; LEE,C.-M.; PEARTON,S.J.; REN,F.; WILSON,R.G.; ZHANG,A.P.

    1999-10-25

    Mesa and planar GaN Schottky diode rectifiers with reverse breakdown voltages (V{sub RB}) up to 550V and >2000V, respectively, have been fabricated. The on-state resistance, R{sub ON}, was 6m{Omega}{center_dot} cm{sup 2} and 0.8{Omega}cm{sup 2}, respectively, producing figure-of-merit values for (V{sub RB}){sup 2}/R{sub ON} in the range 5-48 MW{center_dot}cm{sup -2}. At low biases the reverse leakage current was proportional to the size of the rectifying contact perimeter, while at high biases the current was proportional to the area of this contact. These results suggest that at low reverse biases, the leakage is dominated by the surface component, while at higher biases the bulk component dominates. On-state voltages were 3.5V for the 550V diodes and {ge}15 for the 2kV diodes. Reverse recovery times were <0.2{micro}sec for devices switched from a forward current density of {approx}500A{center_dot}cm{sup -2} to a reverse bias of 100V.

  19. 30 CFR 77.704-1 - Work on high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Work on high-voltage lines. 77.704-1 Section 77... MINES Grounding § 77.704-1 Work on high-voltage lines. (a) No high-voltage line shall be regarded as... provided in § 77.103) that such high-voltage line has been deenergized and grounded. Such qualified person...

  20. A novel on-chip high to low voltage power conversion circuit

    International Nuclear Information System (INIS)

    Wang Hui; Wang Songlin; Mou Zaixin; Guo Baolong; Lai Xinquan; Ye Qiang; Li Xianrui

    2009-01-01

    A novel power supply transform technique for high voltage IC based on the TSMC 0.6 μm BCD process is achieved. An adjustable bandgap voltage reference is presented which is different from the traditional power supply transform technique. It can be used as an internal power supply for high voltage IC by using the push-pull output stage to enhance its load capability. High-order temperature compensated circuit is designed to ensure the precision of the reference. Only 0.01 mm 2 area is occupied using this novel power supply technique. Compared with traditional technique, 50% of the area is saved, 40% quiescent power loss is decreased, and the temperature coefficient of the reference is only 4.48 ppm/deg. C. Compared with the traditional LDO (low dropout) regulator, this power conversion architecture does not need external output capacitance and decreases the chip-pin and external components, so the PCB area and design cost are also decreased. The testing results show that this circuit works well.

  1. A novel on-chip high to low voltage power conversion circuit

    Energy Technology Data Exchange (ETDEWEB)

    Wang Hui; Wang Songlin; Mou Zaixin; Guo Baolong [Institute of Mechano-electronic Engineering, Xidian University, Xi' an 71007 (China); Lai Xinquan; Ye Qiang; Li Xianrui, E-mail: whui94@126.co [Institute of Electronic CAD, Xidian University, Xi' an 710071 (China)

    2009-03-15

    A novel power supply transform technique for high voltage IC based on the TSMC 0.6 mum BCD process is achieved. An adjustable bandgap voltage reference is presented which is different from the traditional power supply transform technique. It can be used as an internal power supply for high voltage IC by using the push-pull output stage to enhance its load capability. High-order temperature compensated circuit is designed to ensure the precision of the reference. Only 0.01 mm{sup 2} area is occupied using this novel power supply technique. Compared with traditional technique, 50% of the area is saved, 40% quiescent power loss is decreased, and the temperature coefficient of the reference is only 4.48 ppm/deg. C. Compared with the traditional LDO (low dropout) regulator, this power conversion architecture does not need external output capacitance and decreases the chip-pin and external components, so the PCB area and design cost are also decreased. The testing results show that this circuit works well.

  2. The Design of Nanosecond Fast-switch Pulsed High Voltage Power Supply Based on Solid-state

    International Nuclear Information System (INIS)

    Chen Wenguang; Chen Wei; Rao Yihua

    2009-01-01

    The high voltage pulsed power supply is applied in the experiment of the nuclear science widely. It main consist of DC high-voltage power supply (HVPS) and pulse modulator. The high-frequency series-resonant inverter technology and IGBT series technology are used to design the HVPS and the modulator, respectively. The main circuit, control circuit, high voltage transformer and solid-state switch are illuminated in the paper. The apparatus can operate at a maximum output voltage of 6 kilovolt, which can be modulated single pulse and also be modulated by series pulse. A prototype is fabricated and tested, experimental results show that the pulsed power supply is well-designed and rising edge time to meet the nsclass; it can achieve the requirement of rapid modulation. (authors)

  3. Novel Interleaved Converter with Extra-High Voltage Gain to Process Low-Voltage Renewable-Energy Generation

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2016-10-01

    Full Text Available This paper presents a novel interleaved converter (NIC with extra-high voltage gain to process the power of low-voltage renewable-energy generators such as photovoltaic (PV panel, wind turbine, and fuel cells. The NIC can boost a low input voltage to a much higher voltage level to inject renewable energy to DC bus for grid applications. Since the NIC has two circuit branches in parallel at frond end to share input current, it is suitable for high power applications. In addition, the NIC is controlled in an interleaving pattern, which has the advantages that the NIC has lower input current ripple, and the frequency of the ripple is twice the switching frequency. Two coupled inductors and two switched capacitors are incorporated to achieve a much higher voltage gain than conventional high step-up converters. The proposed NIC has intrinsic features such as leakage energy totally recycling and low voltage stress on power semiconductor. Thorough theoretical analysis and key parameter design are presented in this paper. A prototype is built for practical measurements to validate the proposed NIC.

  4. Comprehensive Auto CAD

    International Nuclear Information System (INIS)

    Jang, Taekju

    1993-06-01

    This book starts introduction of conception, application system, software for CAD, function of Auto CAD, kinds and function of Auto CAD files. It deals with starting of Auto CAD, dialogue box and Auto CAD interface, utility command, 2D drawing command, check command, control system, dimension, hatching command, layer command, block, 3D drawing, plotting and printing, auto CAD and application of data, supply program of auto CAD, AME and region modeler, EDLIN, script optimization of Auto CAD and composition on demand.

  5. PERI auto-tuning

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, D H; Williams, S [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Chame, J; Chen, C; Hall, M [USC/ISI, Marina del Rey, CA 90292 (United States); Dongarra, J; Moore, S; Seymour, K; You, H [University of Tennessee, Knoxville, TN 37996 (United States); Hollingsworth, J K; Tiwari, A [University of Maryland, College Park, MD 20742 (United States); Hovland, P; Shin, J [Argonne National Laboratory, Argonne, IL 60439 (United States)], E-mail: mhall@isi.edu

    2008-07-15

    The enormous and growing complexity of today's high-end systems has increased the already significant challenges of obtaining high performance on equally complex scientific applications. Application scientists are faced with a daunting challenge in tuning their codes to exploit performance-enhancing architectural features. The Performance Engineering Research Institute (PERI) is working toward the goal of automating portions of the performance tuning process. This paper describes PERI's overall strategy for auto-tuning tools and recent progress in both building auto-tuning tools and demonstrating their success on kernels, some taken from large-scale applications.

  6. Séminaire de l'enseignement technique : Forum AutoCAD 2006 et AutoCAD Mechanical 2006

    - French version only

    CERN Multimedia

    Davide Vitè

    2005-01-01

    Jeudi 17 novembre 2005 de 14:30 à 16:30 - Training Centre Auditorium, Bât 593 Forum AutoCAD 2006 et AutoCAD Mechanical 2006 CADSCHOOL, CH-1207 GENEVE, Suisse Ce nouveau séminaire de l'Enseignement technique, organisé en forme de forum et en collaboration avec TS-MME et notre entreprise partenaire en formation, sera consacré à la présentation de la nouvelle version d'AutoCAD, AutoCAD 2006 et AutoCAD Mechanical 2006, disponible au CERN. Au programme : Présentation d'AutoCAD Mechanical 2006 Améliorations par rapport à AutoCAD Mechanical 6 Power Pack Questions - Réponses Langue: Français. Séminaire libre, sans inscription. Organisateurs: Manfred Mayer / TS-MME / 74499 ; Davide Vitè / HR-PMD / 75141 Pour plus d'information, veuillez SVP visiter les pages des Séminaires de l'Enseignement Technique à l'adresse http://www.cern.ch/TechnicalTraining/special/TTseminars.asp . ENSEIGNEMENT TECHNIQUE TECHNICAL TRAINING technical.training@cern.ch

  7. Complete low power controller for high voltage power systems

    International Nuclear Information System (INIS)

    Sumner, R.; Blanar, G.

    1997-01-01

    The MHV100 is a custom CMOS integrated circuit, developed for the AMS experiment. It provides complete control for a single channel high voltage (HV) generator and integrates all the required digital communications, D to A and A to D converters, the analog feedback loop and output drivers. This chip has been designed for use in both distributed high voltage systems or for low cost single channel high voltage systems. The output voltage and current range is determined by the external components

  8. E-beam high voltage switching power supply

    Science.gov (United States)

    Shimer, Daniel W.; Lange, Arnold C.

    1997-01-01

    A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

  9. E-beam high voltage switching power supply

    International Nuclear Information System (INIS)

    Shimer, D.W.; Lange, A.C.

    1997-01-01

    A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360 degree/n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load. 7 figs

  10. PC-based control of a high-voltage injector

    International Nuclear Information System (INIS)

    Constantin, F.

    1998-01-01

    The stability of high voltage injectors is one of the major problems in any accelerator system. Most of the troubles encountered in the normal operation of an accelerator are connected with the ion source and associated high voltage platforms, regardless of the source or high voltage generator type. The quality of the ion beam injected in the accelerator strongly depends on the power supplies used in the injector and on the ability to control the non-electrical parameters (gas-flow, temperature, etc.). A wide used method in controlling is based on optical links between high-voltage platform and computer, the adjustments being more or less automated. Although the method mentioned above can be still useful in injector control, a different approach is presented in this work, i.e., the computer itself is placed inside the high-voltage terminal. Only one optical link is still necessary to connect this computer with an user-friendly host at ground potential. Requirements: - varying and monitoring the filament current; - gas flow control in the ion source; - reading the vacuum values; - current and voltage control for the anodic, magnet, extraction, suppression and lens' sources. Even in the high voltage terminal there are compartments with different voltages regardless the floating ground. In our injector the extraction voltage is applied on the top of the ion source including the filament and the anodic voltage. The extraction voltage is of maximum 30 kV. In this situation a second optical link is required to transfer the control for the anodic and magnet source power supply assuming the dedicated computer on the floating ground. One PC is placed inside the high voltage terminal and one PC outside the injector. The optical link (more precisely two optical wires) connects the serial ports. The inside computer is equipped with two multipurpose ADC/DAC and digital I/O card. They permit to read or output DC levels ranging between 0 to 10 volts or TTL signals. The filament

  11. High voltage generator circuit with low power and high efficiency applied in EEPROM

    International Nuclear Information System (INIS)

    Liu Yan; Zhang Shilin; Zhao Yiqiang

    2012-01-01

    This paper presents a low power and high efficiency high voltage generator circuit embedded in electrically erasable programmable read-only memory (EEPROM). The low power is minimized by a capacitance divider circuit and a regulator circuit using the controlling clock switch technique. The high efficiency is dependent on the zero threshold voltage (V th ) MOSFET and the charge transfer switch (CTS) charge pump. The proposed high voltage generator circuit has been implemented in a 0.35 μm EEPROM CMOS process. Measured results show that the proposed high voltage generator circuit has a low power consumption of about 150.48 μW and a higher pumping efficiency (83.3%) than previously reported circuits. This high voltage generator circuit can also be widely used in low-power flash devices due to its high efficiency and low power dissipation. (semiconductor integrated circuits)

  12. Suppression of the high-frequency disturbances in low-voltage circuits caused by disconnector operation in high-voltage open-air substations

    Energy Technology Data Exchange (ETDEWEB)

    Savic, M.S.

    1986-07-01

    The switching off and on of small capacitive currents charging busbar capacitances, connection conductors and open circuit breakers with disconnectors causes high-frequency transients in high-voltage networks. In low voltage circuits, these transient processes induce dangerous overvoltages for the electronic equipment in the substation. A modified construction of the disconnector with a damping resistor was investigated. Digital simulation of the transient process in a high-voltage network during the arcing period between the disconnector contacts with and without damping resistor were performed. A significant decrease of the arcing duration and the decrease of the electromagnetic field magnitude in the vicinity of the operating disconnector were noticed. In the low voltage circuit protected with the surge arrester, the overvoltage magnitude was not affected by the damping resistor due to the arrester protection effect.

  13. Experimental validation of prototype high voltage bushing

    Science.gov (United States)

    Shah, Sejal; Tyagi, H.; Sharma, D.; Parmar, D.; M. N., Vishnudev; Joshi, K.; Patel, K.; Yadav, A.; Patel, R.; Bandyopadhyay, M.; Rotti, C.; Chakraborty, A.

    2017-08-01

    Prototype High voltage bushing (PHVB) is a scaled down configuration of DNB High Voltage Bushing (HVB) of ITER. It is designed for operation at 50 kV DC to ensure operational performance and thereby confirming the design configuration of DNB HVB. Two concentric insulators viz. Ceramic and Fiber reinforced polymer (FRP) rings are used as double layered vacuum boundary for 50 kV isolation between grounded and high voltage flanges. Stress shields are designed for smooth electric field distribution. During ceramic to Kovar brazing, spilling cannot be controlled which may lead to high localized electrostatic stress. To understand spilling phenomenon and precise stress calculation, quantitative analysis was performed using Scanning Electron Microscopy (SEM) of brazed sample and similar configuration modeled while performing the Finite Element (FE) analysis. FE analysis of PHVB is performed to find out electrical stresses on different areas of PHVB and are maintained similar to DNB HV Bushing. With this configuration, the experiment is performed considering ITER like vacuum and electrical parameters. Initial HV test is performed by temporary vacuum sealing arrangements using gaskets/O-rings at both ends in order to achieve desired vacuum and keep the system maintainable. During validation test, 50 kV voltage withstand is performed for one hour. Voltage withstand test for 60 kV DC (20% higher rated voltage) have also been performed without any breakdown. Successful operation of PHVB confirms the design of DNB HV Bushing. In this paper, configuration of PHVB with experimental validation data is presented.

  14. Adsorption of SF6 decomposed gas on anatase (101) and (001) surfaces with oxygen defect: A density functional theory study

    Science.gov (United States)

    Zhang, Xiaoxing; Chen, Qinchuan; Tang, Ju; Hu, Weihua; Zhang, Jinbin

    2014-01-01

    The detection of partial discharge by analyzing the components of SF6 gas in gas-insulated switchgears is important to the diagnosis and assessment of the operational state of power equipment. A gas sensor based on anatase TiO2 is used to detect decomposed gases in SF6. In this paper, first-principle density functional theory calculations are adopted to analyze the adsorption of SO2, SOF2, and SO2F2, the primary decomposition by-products of SF6 under partial discharge, on anatase (101) and (001) surfaces. Simulation results show that the perfect anatase (001) surface has a stronger interaction with the three gases than that of anatase (101), and both surfaces are more sensitive and selective to SO2 than to SOF2 and SO2F2. The selection of a defect surface to SO2, SOF2, and SO2F2 differs from that of a perfect surface. This theoretical result is corroborated by the sensing experiment using a TiO2 nanotube array (TNTA) gas sensor. The calculated values are analyzed to explain the results of the Pt-doped TNTA gas sensor sensing experiment. The results imply that the deposited Pt nanoparticles on the surface increase the active sites of the surface and the gas molecules may decompose upon adsorption on the active sites. PMID:24755845

  15. 30 CFR 75.811 - High-voltage underground equipment; grounding.

    Science.gov (United States)

    2010-07-01

    ...-voltage equipment supplying power to such equipment receiving power from resistance grounded systems shall... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage underground equipment; grounding... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage...

  16. AutoCAD / AutoCAD LT 2014 fundamentals metric

    CERN Document Server

    ASCENT center for technical knowledge

    2014-01-01

    The objective of AutoCAD/AutoCAD LT 2014 Fundamentals is to enable students to create a basic 2D drawing in the AutoCAD software. Even at this fundamental level, the AutoCAD software is one of the most sophisticated computer applications that you are likely to encounter. Therefore learning to use it can be challenging. To make the process easier and provide flexibility for instructors and students, the training guide is divided into two parts that can be taken independently.

  17. Auto-ignition of lubricating oil working at high pressures in a compressor for an air conditioner.

    Science.gov (United States)

    Kim, Chul Jin; Choi, Hyo Hyun; Sohn, Chae Hoon

    2011-01-15

    Auto-ignition of lubricating oil working in a compressor for an air conditioner is studied experimentally. The adopted lubricating oil is an unknown mixture with multi-components and known to have flash point temperature of 170 °C. First, its auto-ignition temperature is measured 365 °C at atmospheric pressure. The lubricating oil works under high-pressure condition up to 30 atm and it is heated and cooled down repeatedly. Accordingly, auto-ignition temperatures or flammable limits of lubricating oil are required at high pressures with respect to fire safety. Because there is not a standard test method for the purpose, a new ignition-test method is proposed in this study and thereby, auto-ignition temperatures are measured over the pressure range below 30 atm. The measured temperatures range from 215 °C to 255 °C and they strongly depend on pressure of gas mixture consisting of oil vapor, nitrogen, and oxygen. They are close to flash point temperature and the lubricating oil can be hazardous when it works for high-pressure operating condition and abundant air flows into a compressor. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. Improvement the Capacity of Cockcroft-Walton High Voltage Source from 300 kV/20 mA to 500 kV/20 mA for Accelerating Voltage of Electron Beam Machine

    International Nuclear Information System (INIS)

    Suprapto; Djasiman

    2002-01-01

    The improvement capacity of Cockcroft-Walton high voltage source from 300 kV/20 mA to 500 kV/mA has been carrying out. To improve the capacity of high voltage source was done by means of increasing the stage number of voltage multiplier from 11 to 18 and its output voltage measuring resistance. Each stage of voltage multiplier consists of 2 capacitors and 2 circuits of high voltage diode. This voltage multiplier is constructed using main components of high voltage capacitor and high voltage diode each of 0.22 μF/50 kV and UF 5408 respectively. To avoid stray discharge and corona it was provided with high voltage electrode and corona ring. The test result indicated that the output voltage obtained from 16 stages was 350 kV according to operating condition of 25 MΩ resistive load and first stage voltage of 28.5 kV with oscillator frequency of 24 Hz. That condition requires anode voltage and current of 5.5 kV and 2.5 A respectively. The no load test for 16 stages indicates 400 kV of output voltage and 28.5 kV first stage voltage. Efficiency of high voltage source was 48 % at 6.75 kW of output power. The expected test of 500 kV with 18 stages of voltage multiplier can not be carried out because of some restrictive of loading system. From the test result can be predicted that the output voltage of 500 kV with 18 stages of voltage multiplier requires 31.2 kV of first stage voltage. Then the expected high voltage source of Cockcroft-Walton is capable as accelerating voltage source for Electron Beam Machine with energy of 500 kV. (author)

  19. Measurement of the electron attachment rates for SF6 and C7F14 at Te=0.2 eV in a magnetized Q machine plasma

    International Nuclear Information System (INIS)

    Merlino, Robert L.; Kim, Su-Hyun

    2008-01-01

    Electron attachment rates for SF 6 and C 7 F 14 were measured in a magnetized Q machine plasma at an electron temperature of 0.2±0.02 eV and with neutral gas pressures of P∼10 -4 Torr. The rate constants for attachment to SF 6 and C 7 F 14 were (7.6±2.0)x10 -8 and (2.2±0.9)x10 -7 cm 3 s -1 , respectively.

  20. Simulation and Experimental Study of Arc Column Expansion After Ignition in Low-Voltage Circuit Breakers

    Institute of Scientific and Technical Information of China (English)

    MA Qiang; RONG Mingzhe; WU Yi; XU Tiejun; SUN Zhiqiang

    2008-01-01

    The dynamicprocess of arc pressure and corresponding arc column expansion, which is the main feature after arc ignition and has a significant effect on the breaking behaviour of low -voltage circuit breakers, is studied. By constructing a three dimensional mathematical model of air arc plasma and adopting the Control Volume Method, the parameters of arc plasma including temperature and pressure axe obtained. The variations of pressure field and temperature field with time are simulated. The result indicates that there are six stages for the process of arc column expansion according to the variation of pressure in arc chamber. In the first stage, the maximal pressure locates in the region close to cathode, and in the second stage the maximal pressure shifts to the region close to the anode. In the third stage, the pressure difference between the middle of arc column and the ambient gas is very large, so the arc column begins to expand apparently. In the fourth stage, the pressure wave propagates towards both ends and the maximal pressure appears at the two ends when the pressure wave reaches both sidewalls. In the fifth stage, the pressure wave is reflected and collides in the middle of the arc chamber. In the last stage, the propagation and reflection of pressure wave will repeat several times until a steady burning state is reached. In addition, the experimental results of arc column expansion, corresponding to the arc pressure variation, are presented to verify the simulation results.

  1. High-voltage nanosecond pulse shaper

    International Nuclear Information System (INIS)

    Kapishnikov, N.K.; Muratov, V.M.; Shatanov, A.A.

    1987-01-01

    A high-voltage pulse shaper with an output of up to 250 kV, a base duration of ∼ 10 nsec, and a repetition frequency of 50 pulses/sec is described. The described high-voltage nanosecond pulse shaper is designed for one-orbit extraction of an electron beam from a betatron. A diagram of the pulse shaper, which employs a single-stage generator is shown. The shaping element is a low-inductance capacitor bank of series-parallel KVI-3 (2200 pF at 10 kV) or K15-10 (4700 pF at 31.5 kV) disk ceramic capacitors. Four capacitors are connected in parallel and up to 25 are connected in series

  2. Design of high voltage power supply of miniature X-ray tube based on resonant Royer

    International Nuclear Information System (INIS)

    Liu Xiyao; Zeng Guoqiang; Tan Chengjun; Luo Qun; Gong Chunhui; Huang Rui

    2013-01-01

    Background: In recent years, X rays are widely used in various fields. With the rapid development of national economy, the demand of high quality, high reliability, and high stability miniature X-ray tube has grown rapidly. As an important core component of miniature X-ray tube, high voltage power supply has attracted wide attention. Purpose: To match miniature, the high voltage power supply should be small, lightweight, good quality, etc. Based on the basic performance requirements of existing micro-X-ray tube high voltage power supply, this paper designs an output from 0 to -30 kV adjustable miniature X-ray tube voltage DC power supply. Compared to half-bridge and full-bridge switching-mode power supply, its driving circuit is simple. With working on the linear condition, it has no switching noise. Methods: The main circuit makes use of DC power supply to provide the energy. The resonant Royer circuit supplies sine wave which drives to the high frequency transformer's primary winding with resultant sine-like high voltage appearing across the secondary winding. Then, the voltage doubling rectifying circuit would achieve further boost. In the regulator circuit, a feedback control resonant transistor base current is adopted. In order to insulate air, a silicone rubber is used for high pressure part packaging, and the output voltage is measured by the dividing voltage below -5 kV. Results: The stability of circuit is better than 0.2%/6 h and the percent of the output ripple voltage is less than 0.3%. Keeping the output voltage constant, the output current can reach 57 μA by changing the size of load resistor. This high voltage power supply based on resonant Royer can meet the requirement of miniature X-ray tube. Conclusions: The circuit can satisfy low noise, low ripple, low power and high voltage regulator power supply design. However, its efficiency is not high enough because of the linear condition. In the next design, to further reduce power consumption, we

  3. Analysis of the Sensitivity of K-Type Molecular Sieve-Deposited MWNTs for the Detection of SF6 Decomposition Gases under Partial Discharge

    Science.gov (United States)

    Zhang, Xiaoxing; Li, Xin; Luo, Chenchen; Dong, Xingchen; Zhou, Lei

    2015-01-01

    Sulfur hexafluoride (SF6) is widely utilized in gas-insulated switchgear (GIS). However, part of SF6 decomposes into different components under partial discharge (PD) conditions. Previous research has shown that the gas responses of intrinsic and 4 Å-type molecular sieve-deposited multi-wall carbon nanotubes (MWNTs) to SOF2 and SO2F2, two important decomposition components of SF6, are not obvious. In this study, a K-type molecular sieve-deposited MWNTs sensor was developed. Its gas response characteristics and the influence of the mixture ratios of gases on the gas-sensing properties were studied. The results showed that, for sensors with gas mixture ratios of 5:1, 10:1, and 20:1, the resistance change rate increased by nearly 13.0% after SOF2 adsorption, almost 10 times that of MWNTs sensors, while the sensors’ resistance change rate with a mixture ratio of 10:1 reached 17.3% after SO2F2 adsorption, nearly nine times that of intrinsic MWNT sensors. Besides, a good linear relationship was observed between concentration of decomposition components and the resistance change rate of sensors. PMID:26569245

  4. Analysis of the Sensitivity of K-Type Molecular Sieve-Deposited MWNTs for the Detection of SF6 Decomposition Gases under Partial Discharge

    Directory of Open Access Journals (Sweden)

    Xiaoxing Zhang

    2015-11-01

    Full Text Available Sulfur hexafluoride (SF6 is widely utilized in gas-insulated switchgear (GIS. However, part of SF6 decomposes into different components under partial discharge (PD conditions. Previous research has shown that the gas responses of intrinsic and 4 Å-type molecular sieve-deposited multi-wall carbon nanotubes (MWNTs to SOF2 and SO2F2, two important decomposition components of SF6, are not obvious. In this study, a K-type molecular sieve-deposited MWNTs sensor was developed. Its gas response characteristics and the influence of the mixture ratios of gases on the gas-sensing properties were studied. The results showed that, for sensors with gas mixture ratios of 5:1, 10:1, and 20:1, the resistance change rate increased by nearly 13.0% after SOF2 adsorption, almost 10 times that of MWNTs sensors, while the sensors’ resistance change rate with a mixture ratio of 10:1 reached 17.3% after SO2F2 adsorption, nearly nine times that of intrinsic MWNT sensors. Besides, a good linear relationship was observed between concentration of decomposition components and the resistance change rate of sensors.

  5. Transport coefficients of liquid CF4 and SF6 computed by molecular dynamics using polycenter Lennard-Jones potentials

    Science.gov (United States)

    Hoheisel, C.

    1989-01-01

    For several liquid states of CF4 and SF4, the shear and the bulk viscosity as well as the thermal conductivity were determined by equilibrium molecular dynamics (MD) calculations. Lennard-Jones four- and six-center pair potentials were applied, and the method of constraints was chosen for the MD. The computed Green-Kubo integrands show a steep time decay, and no particular longtime behavior occurs. The molecule number dependence of the results is found to be small, and 3×105 integration steps allow an accuracy of about 10% for the shear viscosity and the thermal conductivity coefficient. Comparison with experimental data shows a fair agreement for CF4, while for SF6 the transport coefficients fall below the experimental ones by about 30%.

  6. Near-critical density filling of the SF6 fluid cell for the ALI-R-DECLIC experiment in weightlessness

    Science.gov (United States)

    Lecoutre, C.; Marre, S.; Garrabos, Y.; Beysens, D.; Hahn, I.

    2018-05-01

    Analyses of ground-based experiments on near-critical fluids to precisely determine their density can be hampered by several effects, especially the density stratification of the sample, the liquid wetting behavior at the cell walls, and a possible singular curvature of the "rectilinear" diameter of the density coexisting curve. For the latter effect, theoretical efforts have been made to understand the amplitude and shape of the critical hook of the density diameter, which depart from predictions from the so-called ideal lattice-gas model of the uniaxial 3D-Ising universality class. In order to optimize the observation of these subtle effects on the position and shape of the liquid-vapor meniscus in the particular case of SF6, we have designed and filled a cell that is highly symmetrized with respect to any median plane of the total fluid volume. In such a viewed quasi-perfect symmetrical fluid volume, the precise detection of the meniscus position and shape for different orientations of the cell with respect to the Earth's gravity acceleration field becomes a sensitive probe to estimate the cell mean density filling and to test the singular diameter effects. After integration of this cell in the ALI-R insert, we take benefit of the high optical and thermal performances of the DECLIC Engineering Model. Here we present the sensitive imaging method providing the precise ground-based SF6 benchmark data. From these data analysis it is found that the temperature dependence of the meniscus position does not reflect the expected critical hook in the rectilinear density diameter. Therefore the off-density criticality of the cell is accurately estimated, before near future experiments using the same ALI-R insert in the DECLIC facility already on-board the International Space Station.

  7. Comparison of the Multiattribute Utility Instruments EQ-5D and SF-6D in a Europe-Wide Population-Based Cohort of Patients with Inflammatory Bowel Disease 10 Years after Diagnosis.

    Science.gov (United States)

    Huppertz-Hauss, Gert; Aas, Eline; Lie Høivik, Marte; Langholz, Ebbe; Odes, Selwyn; Småstuen, Milada; Stockbrugger, Reinhold; Hoff, Geir; Moum, Bjørn; Bernklev, Tomm

    2016-01-01

    Background. The treatment of chronic inflammatory bowel disease (IBD) is costly, and limited resources call for analyses of the cost effectiveness of therapeutic interventions. The present study evaluated the equivalency of the Short Form 6D (SF-6D) and the Euro QoL (EQ-5D), two preference-based HRQoL instruments that are broadly used in cost-effectiveness analyses, in an unselected IBD patient population. Methods. IBD patients from seven European countries were invited to a follow-up visit ten years after their initial diagnosis. Clinical and demographic data were assessed, and the Short Form 36 (SF-36) was employed. Utility scores were obtained by calculating the SF-6D index values from the SF-36 data for comparison with the scores obtained with the EQ-5D questionnaire. Results. The SF-6D and EQ-5D provided good sensitivities for detecting disease activity-dependent utility differences. However, the single-measure intraclass correlation coefficient was 0.58, and the Bland-Altman plot indicated numerous values beyond the limits of agreement. Conclusions. There was poor agreement between the measures retrieved from the EQ-5D and the SF-6D utility instruments. Although both instruments may provide good sensitivity for the detection of disease activity-dependent utility differences, the instruments cannot be used interchangeably. Cost-utility analyses performed with only one utility instrument must be interpreted with caution.

  8. SF{sub 6} decomposition and layer formation due to excimer laser photoablation of SiO{sub 2} surface at gas-solid system

    Energy Technology Data Exchange (ETDEWEB)

    Sajad, Batool [Physics Department, Amirkabir University, PO Box 15875-4413, Tehran (Iran, Islamic Republic of); Parvin, Parviz [Physics Department, Amirkabir University, PO Box 15875-4413, Tehran (Iran, Islamic Republic of); Bassam, Mohamad Amin [Excimer Laser Lab, Emam Hussain University, PO Box 16575-4347, Tehrann (Iran, Islamic Republic of)

    2004-12-21

    In this work, the effect of an excimer laser has been studied for presenting a method for SF{sub 6} decomposition and simultaneous formation of a SiF{sub 2} layer on amorphous SiO{sub 2}. Though the excimer laser did not establish a gas phase photodissociation, we have shown that UV photoablation leads strongly to molecular decomposition in the SF{sub 6}-SiO{sub 2} system. Moreover, the dependence of the decomposition process on the exposure parameters such as the wavelength and intensity as well as the gas pressure and the focal point distance from the gas-solid interface has been investigated.

  9. High Voltage Resistive Divider Based on Cast Microwire in Glass Insulation on 6–24 kV Alternating Current of Commercial Frequency.

    Directory of Open Access Journals (Sweden)

    Juravleov A.

    2008-12-01

    Full Text Available It is presented the analysis and description of the construction of the high voltage resistive divider on the base of cast microwire in glass insulation on 6–24 kV alternating current of commercial frequency. It is presented the procedure of compensation of frequency error during the process of fabrication of divides and results of tests of the sample model of the divider as well.

  10. Ozone-depleting substances and the greenhouse gases HFCs, PFCs and SF{sub 6}. Danish consumption and emissions, 2006

    Energy Technology Data Exchange (ETDEWEB)

    Sander Poulsen, T. (PlanMiljoe (Denmark))

    2007-07-01

    The objective of this project was to map the 2006 consumption of newly produced industrial ozone-depleting substances and the consumption and actual emissions of HFCs, PFCs, and SF{sub 6}. The evaluation was made in accordance with the IPCC guidelines and following the method employed in previous evaluations. (BA)

  11. PV source based high voltage gain current fed converter

    Science.gov (United States)

    Saha, Soumya; Poddar, Sahityika; Chimonyo, Kudzai B.; Arunkumar, G.; Elangovan, D.

    2017-11-01

    This work involves designing and simulation of a PV source based high voltage gain, current fed converter. It deals with an isolated DC-DC converter which utilizes boost converter topology. The proposed converter is capable of high voltage gain and above all have very high efficiency levels as proved by the simulation results. The project intends to produce an output of 800 V dc from a 48 V dc input. The simulation results obtained from PSIM application interface were used to analyze the performance of the proposed converter. Transformer used in the circuit steps up the voltage as well as to provide electrical isolation between the low voltage and high voltage side. Since the converter involves high switching frequency of 100 kHz, ultrafast recovery diodes are employed in the circuitry. The major application of the project is for future modeling of solar powered electric hybrid cars.

  12. Theoretical and experimental studies of N and SF2 reaction

    International Nuclear Information System (INIS)

    Yu Shuqin; Zhou Xiaoguo

    2000-02-01

    In this paper, free radical reaction of N+SF 2 induced by dc discharge in N 2 and SF 6 system was examined. Although the NS + (m/z = 46) ion signals were detected, NS + is not the spectral carrier from obtained REMPI spectra analysis. Ab initio quantum calculation shows that NSF is the main product of N + SF 2 . It is confirmed from this calculation that NS + obtained in experiment was produced by multiphoton ionization and dissociation of NSF which is real product of N + SF 2 reaction. (author)

  13. 30 CFR 77.804 - High-voltage trailing cables; minimum design requirements.

    Science.gov (United States)

    2010-07-01

    ... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.804 High-voltage trailing cables; minimum design requirements. (a) High-voltage trailing cables used in resistance grounded systems shall be... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage trailing cables; minimum design...

  14. A single gas chromatograph for accurate atmospheric mixing ratio measurements of CO2, CH4, N2O, SF6 and CO

    Directory of Open Access Journals (Sweden)

    H. A. J. Meijer

    2009-09-01

    Full Text Available We present an adapted gas chromatograph capable of measuring simultaneously and semi-continuously the atmospheric mixing ratios of the greenhouse gases CO2, CH4, N2O and SF6 and the trace gas CO with high precision and long-term stability. The novelty of our design is that all species are measured with only one device, making it a very cost-efficient system. No time lags are introduced between the measured mixing ratios. The system is designed to operate fully autonomously which makes it ideal for measurements at remote and unmanned stations. Only a small amount of sample air is needed, which makes this system also highly suitable for flask air measurements. In principle, only two reference cylinders are needed for daily operation and only one calibration per year against international WMO standards is sufficient to obtain high measurement precision and accuracy. The system described in this paper is in use since May 2006 at our atmospheric measurement site Lutjewad near Groningen, The Netherlands at 6°21´ E, 53°24´N, 1 m a.s.l. Results show the long-term stability of the system. Observed measurement precisions at our remote research station Lutjewad were: ±0.04 ppm for CO2, ±0.8 ppb for CH4, ±0.8 ppb for CO, ±0.3 ppb for N2O, and ±0.1 ppt for SF6. The ambient mixing ratios of all measured species as observed at station Lutjewad for the period of May 2007 to August 2008 are presented as well.

  15. AutoCAD 2015 and AutoCAD LT 2015 bible

    CERN Document Server

    Finkelstein, Ellen

    2014-01-01

    The perfect reference for all AutoCAD users AutoCAD 2015 and AutoCAD LT 2015 Bible is the book you want to have close at hand to answer those day-to-day questions about this industry-leading software. Author and Autodesk University instructor Ellen Finkelstein guides readers through AutoCAD 2015 and AutoCAD LT 2015 with clear, easy-to-understand instruction and hands-on tutorials that allow even total beginners to create a design on their very first day. Although simple and fundamental enough to be used by those new to CAD, the book is so comprehensive that even Autodesk power u

  16. AutoCAD 2012 and AutoCAD LT 2012 Bible

    CERN Document Server

    Finkelstein, Ellen

    2011-01-01

    The latest version of this perennial favorite, in-depth, reference-tutorial This top-selling book has been updated by AutoCAD guru and author Ellen Finkelstein to provide you with the very latest coverage of both AutoCAD 2012 and AutoCAD LT 2012. It begins with a Quick Start tutorial, so you start creating right away. From there, the book covers so much in-depth material on AutoCAD that it is said that even Autodesk employees keep this comprehensive book at their desks. A DVD is included that features before-and-after drawings of all the tutorials and plenty of great examples from AutoCAD prof

  17. The high voltage homopolar generator

    Science.gov (United States)

    Price, J. H.; Gully, J. H.; Driga, M. D.

    1986-11-01

    System and component design features of proposed high voltage homopolar generator (HVHPG) are described. The system is to have an open circuit voltage of 500 V, a peak output current of 500 kA, 3.25 MJ of stored inertial energy and possess an average magnetic-flux density of 5 T. Stator assembly components are discussed, including the stator, mount structure, hydrostatic bearings, main and motoring brushgears and rotor. Planned operational procedures such as monitoring the rotor to full speed and operation with a superconducting field coil are delineated.

  18. A new VME based high voltage power supply for large experiments

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, S.C.; Angstadt, R.D.; Droege, T.F.; Johnson, M.E.; MacKinnon, B.A.; McNulty, S.E.; Shea, M.F.; Thompson, R.N.; Watson, M.M. (Fermi National Accelerator Lab., Batavia, IL (United States)); Franzini, P. (Columbia Univ., New York, NY (United States)); Jones, A.A. (Superconducting Super Collider Lab., Dallas, TX (United States)); Lopez, M.L. (La Plata Univ. Nacional (Argentina)); Wimpenny, S.J.; Yang, M.J

    1991-11-01

    A new VME based high voltage power supply has been developed for the D{O} experiment at Fermilab. There are three types of supplies delivering up to {plus minus}5.6 kV at 1.0 mA or +2.0 kV at 3.0 mA with a set accuracy of 1.5 V and extremely low voltage ripples. Complete computer control has allowed many special features to be developed for the supply, including user-defined control land monitor groups, variable ramp rates, and advanced histogram and graphic functions. 3 refs.

  19. A new VME based high voltage power supply for large experiments

    International Nuclear Information System (INIS)

    Ahn, S.C.; Angstadt, R.D.; Droege, T.F.; Johnson, M.E.; MacKinnon, B.A.; McNulty, S.E.; Shea, M.F.; Thompson, R.N.; Watson, M.M.; Franzini, P.; Jones, A.A.; Lopez, M.L.; Wimpenny, S.J.; Yang, M.J.

    1991-11-01

    A new VME based high voltage power supply has been developed for the D OE experiment at Fermilab. There are three types of supplies delivering up to ±5.6 kV at 1.0 mA or +2.0 kV at 3.0 mA with a set accuracy of 1.5 V and extremely low voltage ripples. Complete computer control has allowed many special features to be developed for the supply, including user-defined control land monitor groups, variable ramp rates, and advanced histogram and graphic functions. 3 refs

  20. Auto Detection For High Level Water Content For Oil Well

    Science.gov (United States)

    Janier, Josefina Barnachea; Jumaludin, Zainul Arifin B.

    2010-06-01

    Auto detection of high level water content for oil well is a system that measures the percentage of water in crude oil. This paper aims to discuss an auto detection system for measuring the content of water level in crude oil which is applicable for offshore and onshore oil operations. Data regarding water level content from wells can be determined by using automation thus, well with high water level can be determined immediately whether to be closed or not from operations. Theoretically the system measures the percentage of two- fluid mixture where the fluids have different electrical conductivities which are water and crude oil. The system made use of grid sensor which is a grid pattern like of horizontal and vertical wires. When water occupies the space at the intersection of vertical and horizontal wires, an electrical signal is detected which proved that water completed the circuit path in the system. The electrical signals are counted whereas the percentage of water is determined from the total electrical signals detected over electrical signals provided. Simulation of the system using the MultiSIM showed that the system provided the desired result.

  1. CF3SF5 : a ‘super’ greenhouse gas

    OpenAIRE

    Tuckett, R. P.

    2008-01-01

    One molecule of the anthropogenic pollutant trifluoromethyl sulphur pentafluoride (CF\\(_3\\)SF\\(_5\\)), an adduct of the CF\\(_3\\) and SF\\(_5\\) free radicals, causes more global warming than one molecule of any other greenhouse gas yet detected in the Earth’s atmosphere. That is, it has the highest per molecule radiative forcing of any greenhouse pollutant, and the value of its global warming potential is only exceeded by that of SF\\(_6\\). First, the greenhouse effect is described, the propertie...

  2. Voltage Balancing Method on Expert System for 51-Level MMC in High Voltage Direct Current Transmission

    Directory of Open Access Journals (Sweden)

    Yong Chen

    2016-01-01

    Full Text Available The Modular Multilevel Converters (MMC have been a spotlight for the high voltage and high power transmission systems. In the VSC-HVDC (High Voltage Direct Current based on Voltage Source Converter transmission system, the energy of DC link is stored in the distributed capacitors, and the difference of capacitors in parameters and charge rates causes capacitor voltage balance which affects the safety and stability of HVDC system. A method of MMC based on the expert system for reducing the frequency of the submodules (SMs of the IGBT switching frequency is proposed. Firstly, MMC with 51 levels for HVDC is designed. Secondly, the nearest level control (NLC for 51-level MMC is introduced. Thirdly, a modified capacitor voltage balancing method based on expert system for MMC-based HVDC transmission system is proposed. Finally, a simulation platform for 51-level Modular Multilevel Converter is constructed by using MATLAB/SIMULINK. The results indicate that the strategy proposed reduces the switching frequency on the premise of keeping submodule voltage basically identical, which greatly reduces the power losses for MMC-HVDC system.

  3. Solid-state high voltage modulator and its application to rf source high voltage power supplies

    International Nuclear Information System (INIS)

    Tooker, J.F.; Huynh, P.; Street, R.W.

    2009-01-01

    A solid-state high voltage modulator is described in which series-connected insulated-gate bipolar transistors (IGBTs) are switched at a fixed frequency by a pulse width modulation (PWM) regulator, that adjusts the pulse width to control the voltage out of an inductor-capacitor filter network. General Atomics proposed the HV power supply (HVPS) topology of multiple IGBT modulators connected to a common HVdc source for the large number of 1 MW klystrons in the linear accelerator of the Accelerator Production of Tritium project. The switching of 24 IGBTs to obtain 20 kVdc at 20 A for short pulses was successfully demonstrated. This effort was incorporated into the design of a -70 kV, 80 A, IGBT modulator, and in a short-pulse test 12 IGBTs regulated -5 kV at 50 A under PWM control. These two tests confirm the practicality of solid-state IGBT modulators to regulate high voltage at reasonable currents. Tokamaks such as ITER require large rf heating and current drive systems with multiple rf sources. A HVPS topology is presented that readily adapts to the three rf heating systems on ITER. To take advantage of the known economy of scale for power conversion equipment, a single HVdc source feeds multiple rf sources. The large power conversion equipment, which is located outside, converts the incoming utility line voltage directly to the HVdc needed for the class of rf sources connected to it, to further reduce cost. The HVdc feeds a set of IGBT modulators, one for each rf source, to independently control the voltage applied to each source, maximizing operational flexibility. Only the modulators are indoors, close to the rf sources, minimizing the use of costly near-tokamak floor space.

  4. High voltage capacitor design and the determination of solid dielectric voltage breakdown

    International Nuclear Information System (INIS)

    Hutapea, S.

    1976-01-01

    The value of the external field intensity serves as an electrical insulating material and is a physical characteristic of the substance. Capacitor discharge in the dielectric medium are experimentally investigated. The high voltage power supply and other instrument needed are briefly discussed. Capacitors with working voltage of 30.000 volt and the plastic being used for dielectrics in the capacitors are also discussed. (author)

  5. Brakes. Auto Mechanics Curriculum Guide. Module 6. Instructor's Guide.

    Science.gov (United States)

    Allain, Robert

    This module is the sixth of nine modules in the competency-based Missouri Auto Mechanics Curriculum Guide. Eight units cover: introduction to automotive brake systems; disc and drum brake system components and how they operate; properties of brake fluid and procedures for bleeding the brake system; diagnosing and determining needed repairs on…

  6. Calibration of the precision high voltage dividers of the KATRIN experiment

    Energy Technology Data Exchange (ETDEWEB)

    Rest, Oliver [Institut fuer Kernphysik, Westfaelische Wilhelms-Universitaet Muenster (Germany); Collaboration: KATRIN-Collaboration

    2016-07-01

    The KATRIN (KArlsruhe TRItium Neutrino) experiment will measure the endpoint region of the tritium β decay spectrum to determine the neutrino mass with a sensitivity of 200 meV/c{sup 2}. To achieve this sub-eV sensitivity the energy of the decay electrons will be analyzed using a MAC-E type spectrometer. The retarding potential of the MAC-E-filter (up to -35 kV) has to be monitored with a relative precision of 3 . 10{sup -6}. For this purpose the potential will be measured directly via two custom made precision high voltage dividers, which were developed and constructed in cooperation with the Physikalisch-Technische Bundesanstalt Braunschweig. In order to determine the absolute values and the stability of the scale factors of the voltage dividers, regular calibration measurements are essential. Such measurements have been performed during the last years using several different methods. The poster gives an overview of the methods and results of the calibration of the precision high voltage dividers.

  7. Compositions, thermodynamic properties, and transport coefficients of high-temperature C5F10O mixed with CO2 and O2 as substitutes for SF6 to reduce global warming potential

    OpenAIRE

    Linlin Zhong; Mingzhe Rong; Xiaohua Wang; Junhui Wu; Guiquan Han; Guohui Han; Yanhui Lu; Aijun Yang; Yi Wu

    2017-01-01

    C5F10O has recently been found to be a very promising alternative to SF6. This paper is devoted to the investigation of compositions, thermodynamic properties, and transport coefficients of high-temperature C5F10O mixed with CO2 and O2. Firstly, the partition functions and enthalpies of formation for a few molecules (CxFy and CxFyO) which are likely to exist in the mixtures, are calculated based on the G4(MP2) theory. The isomers of the above molecules are selected according to their Gibbs en...

  8. Design status and procurement activities of the High Voltage Deck 1 and Bushing for the ITER Neutral Beam Injector

    International Nuclear Information System (INIS)

    Boldrin, Marco; De Lorenzi, Antonio; Decamps, Hans; Grando, Luca; Simon, Muriel; Toigo, Vanni

    2013-01-01

    Highlights: ► ITER Neutral Beam Injector includes several non-standard components. ► The design status of the −1 MV dc HVD1 and Bushing is described. ► The paper reports also on the integrated layout of the two components. ► Preliminary electrostatic and thermal analyses are presented. ► Procurement activities are outlined. -- Abstract: The ITER Neutral Beam Injector (NBI) power supply system includes several non-standard components, whose ratings go beyond the present industrial practice. Two of these items, to be procured by Fusion for Energy, are: 1.A −1 MV dc air-insulated Faraday cage, called High Voltage Deck 1 (HVD1), hosting the Ion Source and Extractor Power Supplies (ISEPS) and the associated diagnostics. 2.A −1 MV dc feedthrough, called HVD1-TL Bushing, aimed at connecting the HVD1 to the gas (SF 6 ) insulated Transmission Line (TL), containing inside its High Voltage (HV) conductor all ISEPS power and control cables coming from the HVD1 to be connected to the NBI Ion Source services. The paper deals with the status of the design of the HVD1 and HVD1-TL Bushing, focusing on insulation, mechanical and thermal issues as well as on their integration with the other components of the power supply system. In particular, the insulation issue of the integrated system has been addressed by means of an electrostatic Finite Element (FE) analysis whilst a FE thermal simulation has been carried out to assess the impact of the dissipation of the proposed design of the inner conductors (ISEPS conductors) not actively cooled. Finally, the paper describes the status of procurement strategy and execution

  9. Comparison of the Multiattribute Utility Instruments EQ-5D and SF-6D in a Europe-Wide Population-Based Cohort of Patients with Inflammatory Bowel Disease 10 Years after Diagnosis

    Directory of Open Access Journals (Sweden)

    Gert Huppertz-Hauss

    2016-01-01

    Full Text Available Background. The treatment of chronic inflammatory bowel disease (IBD is costly, and limited resources call for analyses of the cost effectiveness of therapeutic interventions. The present study evaluated the equivalency of the Short Form 6D (SF-6D and the Euro QoL (EQ-5D, two preference-based HRQoL instruments that are broadly used in cost-effectiveness analyses, in an unselected IBD patient population. Methods. IBD patients from seven European countries were invited to a follow-up visit ten years after their initial diagnosis. Clinical and demographic data were assessed, and the Short Form 36 (SF-36 was employed. Utility scores were obtained by calculating the SF-6D index values from the SF-36 data for comparison with the scores obtained with the EQ-5D questionnaire. Results. The SF-6D and EQ-5D provided good sensitivities for detecting disease activity-dependent utility differences. However, the single-measure intraclass correlation coefficient was 0.58, and the Bland-Altman plot indicated numerous values beyond the limits of agreement. Conclusions. There was poor agreement between the measures retrieved from the EQ-5D and the SF-6D utility instruments. Although both instruments may provide good sensitivity for the detection of disease activity-dependent utility differences, the instruments cannot be used interchangeably. Cost-utility analyses performed with only one utility instrument must be interpreted with caution.

  10. [Trial digitalization of analog-data obtained from the AutoAnalyzer].

    Science.gov (United States)

    Omori, S

    2000-10-01

    The AutoAnalzer(Basic Model) manufactured on Technicon corporation was a very useful instrument for clinical laboratory automation, but it was necessary to convert the data obtained from the instrument to digital values used the chart reader. This was very troublesome and there was apprehension that there would be errors in A-D conversion. We tried converting data obtained from the AutoAnalzer to a digital value by on-line connection of the instruments with minicomputers(LINC-8 and FACOM-R). The output of the recorder was converted to voltage(0 to 100 V) using a potentiometer, quantitated(0 to 1.000) by the A-D converter attached to LINC-8, and processed by the minicomputer. The control-box was an experimental device mainly designed for the convenience of users. The functions of the control-box were designated analytical items, No. of A-D converters, start and stop of the AutoAnalzer operation to the minicomputer. Employing the control-box, a technician operated this system freely, without direct computer operation. We established a generally satisfactory system for clinical laboratory automation using the minicomputer.

  11. 30 CFR 77.807-1 - High-voltage powerlines; clearances above ground.

    Science.gov (United States)

    2010-07-01

    ... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.807-1 High-voltage powerlines; clearances above ground. High-voltage powerlines located above driveways, haulageways, and railroad tracks...

  12. Design and Implementation of a High Efficiency, Low Component Voltage Stress, Single-Switch High Step-Up Voltage Converter for Vehicular Green Energy Systems

    Directory of Open Access Journals (Sweden)

    Yu-En Wu

    2016-09-01

    Full Text Available In this study, a novel, non-isolated, cascade-type, single-switch, high step-up DC/DC converter was developed for green energy systems. An integrated coupled inductor and voltage lift circuit were applied to simplify the converter structure and satisfy the requirements of high efficiency and high voltage gain ratios. In addition, the proposed structure is controllable with a single switch, which effectively reduces the circuit cost and simplifies the control circuit. With the leakage inductor energy recovery function and active voltage clamp characteristics being present, the circuit yields optimizable conversion efficiency and low component voltage stress. After the operating principles of the proposed structure and characteristics of a steady-state circuit were analyzed, a converter prototype with 450 W, 40 V of input voltage, 400 V of output voltage, and 95% operating efficiency was fabricated. The Renesas MCU RX62T was employed to control the circuits. Experimental results were analyzed to validate the feasibility and effectiveness of the proposed system.

  13. High-voltage test and measuring techniques

    CERN Document Server

    Hauschild, Wolfgang

    2014-01-01

    It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  14. Design and Implementation of a High-Voltage Generator with Output Voltage Control for Vehicle ER Shock-Absorber Applications

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2013-01-01

    Full Text Available A self-oscillating high-voltage generator is proposed to supply voltage for a suspension system in order to control the damping force of an electrorheological (ER fluid shock absorber. By controlling the output voltage level of the generator, the damping force in the ER fluid shock absorber can be adjusted immediately. The shock absorber is part of the suspension system. The high-voltage generator drives a power transistor based on self-excited oscillation, which converts dc to ac. A high-frequency transformer with high turns ratio is used to increase the voltage. In addition, the system uses the car battery as dc power supply. By regulating the duty cycle of the main switch in the buck converter, the output voltage of the buck converter can be linearly adjusted so as to obtain a specific high voltage for ER. The driving system is self-excited; that is, no additional external driving circuit is required. Thus, it reduces cost and simplifies system structure. A prototype version of the actual product is studied to measure and evaluate the key waveforms. The feasibility of the proposed system is verified based on experimental results.

  15. IBM-PC based high voltage controller [Paper No.: L7

    International Nuclear Information System (INIS)

    Mondal, N.K.; Kalmani, S.D.

    1993-01-01

    A simple IBM-PC/XT based high voltage controller is designed for C.A.E.N. high voltage supply unit, which is being used for testing the prototype detector for future accelerator experiment. The high voltage output of the supply unit can be remotely programmed. The V-set Lemo connectors at the rear panel provides the remote control facility. Similarly V-mon and I-mon can be used for remotely monitoring the voltage set and the current drawn from the supply unit. The controller described here sets the high voltage through V-set and monitors the voltage set, through V-mon at a pre-determined time interval. The monitoring is a background job and is done as an interrupt service routine of IRQ3. A simple menu driven software package used is written in Q-Basic and MASM. (author). 1 fig

  16. Solid State High Voltage Supply for EB and X-Ray Generators

    Czech Academy of Sciences Publication Activity Database

    Zobač, Martin; Vlček, Ivan

    2009-01-01

    Roč. 44, 5-6 (2009), s. 73-75 ISSN 0861-4717 R&D Projects: GA AV ČR KAN300100702 Institutional research plan: CEZ:AV0Z20650511 Keywords : high voltage supply * electron beam generator * x-ray generator Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  17. Optical control system for high-voltage terminals

    International Nuclear Information System (INIS)

    Bicek, J.J.

    1978-01-01

    An optical control system for the control of devices in the terminal of an electrostatic accelerator includes a laser that is modulated by a series of preselected codes produced by an encoder. A photodiode receiver is placed in the laser beam at the high-voltage terminal of an electrostatic accelerator. A decoder connected to the photodiode decodes the signals to provide control impulses for a plurality of devices at the high voltage of the terminal

  18. AutoCAD platform customization user interface, AutoLISP, VBA, and beyond

    CERN Document Server

    Ambrosius, Lee

    2015-01-01

    Take control of AutoCAD to boost the speed, quality, and precision of your work Senior drafters and savvy users are increasingly taking AutoCAD customization out of the hands of system administrators, and taking control of their own workflow. In AutoCAD Platform Customization, Autodesk customization guru Lee Ambrosius walks you through a multitude of customization options using detailed tutorials and real-world examples applicable to AutoCAD, AutoCAD LT, Civil 3D, Plant 3D, and other programs built on the AutoCAD platform. By unleashing the full power of the software, you'll simplify and str

  19. TiN coated aluminum electrodes for DC high voltage electron guns

    International Nuclear Information System (INIS)

    Mamun, Md Abdullah A.; Elmustafa, Abdelmageed A.; Taus, Rhys; Forman, Eric; Poelker, Matthew

    2015-01-01

    Preparing electrodes made of metals like stainless steel, for use inside DC high voltage electron guns, is a labor-intensive and time-consuming process. In this paper, the authors report the exceptional high voltage performance of aluminum electrodes coated with hard titanium nitride (TiN). The aluminum electrodes were comparatively easy to manufacture and required only hours of mechanical polishing using silicon carbide paper, prior to coating with TiN by a commercial vendor. The high voltage performance of three TiN-coated aluminum electrodes, before and after gas conditioning with helium, was compared to that of bare aluminum electrodes, and electrodes manufactured from titanium alloy (Ti-6Al-4V). Following gas conditioning, each TiN-coated aluminum electrode reached −225 kV bias voltage while generating less than 100 pA of field emission (<10 pA) using a 40 mm cathode/anode gap, corresponding to field strength of 13.7 MV/m. Smaller gaps were studied to evaluate electrode performance at higher field strength with the best performing TiN-coated aluminum electrode reaching ∼22.5 MV/m with field emission less than 100 pA. These results were comparable to those obtained from our best-performing electrodes manufactured from stainless steel, titanium alloy and niobium, as reported in references cited below. The TiN coating provided a very smooth surface and with mechanical properties of the coating (hardness and modulus) superior to those of stainless steel, titanium-alloy, and niobium electrodes. These features likely contributed to the improved high voltage performance of the TiN-coated aluminum electrodes

  20. High-voltage pulse generator for electron gun power supply

    International Nuclear Information System (INIS)

    Korenev, S.A.; Enchevich, I.B.; Mikhov, M.K.

    1987-01-01

    High-voltage pulse generator with combined capacitive and inductive energy storages for electron gun power supply is described. Hydrogen thyratron set in a short magnetic lense is a current breaker. Times of current interruption in thyratrons are in the range from 100 to 300 ns. With 1 kV charging voltage of capacitive energy storage 25 kV voltage pulse is obtained in the load. The given high-voltage pulse generator was used for supply of an electron gun generating 10-30 keV low-energy electron beam

  1. 21 CFR 892.1700 - Diagnostic x-ray high voltage generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic x-ray high voltage generator. 892.1700... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1700 Diagnostic x-ray high voltage generator. (a) Identification. A diagnostic x-ray high voltage generator is a device that is intended to...

  2. 30 CFR 75.705-1 - Work on high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Work on high-voltage lines. 75.705-1 Section 75... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.705-1 Work on high-voltage lines. (a) Section 75.705 specifically prohibits work on energized high-voltage lines underground; (b...

  3. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.; Abdelghany, Mohamed A.; Elsayed, Mohannad Yomn; Elshurafa, Amro M; Salama, Khaled N.

    2014-01-01

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  4. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  5. A Comparison of SF-36 and SF-12 Composite Scores and Subsequent Hospitalization and Mortality Risks in Long-Term Dialysis Patients

    Science.gov (United States)

    Xu, Jianglin; Lin, Shu-Fang; Dean, Sandie Guerra; Lazarus, J. Michael; Hakim, Raymond M.

    2010-01-01

    Background and objectives: The Short Form 12 (SF-12) has not been validated for long-term dialysis patients. The study compared physical and mental component summary (PCS/MCS) scores from the SF-36 with those from the embedded SF-12 in a national cohort of dialysis patients. Design, setting, participants, & measurements: All 44,395 patients who had scorable SF-36 and SF-12 from January 1, 2006, to December 31, 2006, and were treated at Fresenius Medical Care, North America facilities were included. Death and first hospitalization were followed for up to 1 year from the date of survey. Correlation and agreement were obtained between PCS-36 and PCS-12 and MCS-36 and MCS-12; then Cox models were constructed to compare associated hazard ratios (HRs) between them. Results: Physical and mental dimensions both exhibited excellent intraclass correlation coefficients of 0.94. Each incremental point for both PCS-12 and PCS-36 was associated with a 2.4% lower adjusted HR of death and 0.4% decline in HR for first hospitalization (both P < 0.0001). Corresponding improvement in HR of death for each MCS point was 1.2% for MCS-12 and 1.3% for MCS-36, whereas both had similar 0.6% lower HR for hospitalization per point (all P < 0.0001). Conclusions: The use of the SF-12 alone or as part of a larger survey is valid in dialysis patients. Composite scores from the SF-12 and SF-36 have similar prognostic association with death and hospitalization risk. Prospective longitudinal studies of SF-12 surveys that consider responsiveness to specific clinical, situational, and interventional changes are needed in this population. PMID:20019120

  6. Modular High Voltage Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    Newell, Matthew R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-18

    The goal of this project is to develop a modular high voltage power supply that will meet the needs of safeguards applications and provide a modular plug and play supply for use with standard electronic racks.

  7. A compact 100 kV high voltage glycol capacitor.

    Science.gov (United States)

    Wang, Langning; Liu, Jinliang; Feng, Jiahuai

    2015-01-01

    A high voltage capacitor is described in this paper. The capacitor uses glycerol as energy storage medium, has a large capacitance close to 1 nF, can hold off voltages of up to 100 kV for μs charging time. Allowing for low inductance, the capacitor electrode is designed as coaxial structure, which is different from the common structure of the ceramic capacitor. With a steady capacitance at different frequencies and a high hold-off voltage of up to 100 kV, the glycol capacitor design provides a potential substitute for the ceramic capacitors in pulse-forming network modulator to generate high voltage pulses with a width longer than 100 ns.

  8. 30 CFR 77.704-2 - Repairs to energized high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Repairs to energized high-voltage lines. 77.704... UNDERGROUND COAL MINES Grounding § 77.704-2 Repairs to energized high-voltage lines. An energized high-voltage... repairs will be performed on power circuits with a phase-to-phase nominal voltage no greater than 15,000...

  9. High-voltage electrode optimization towards uniform surface treatment by a pulsed volume discharge

    International Nuclear Information System (INIS)

    Ponomarev, A V; Pedos, M S; Scherbinin, S V; Mamontov, Y I; Ponomarev, S V

    2015-01-01

    In this study, the shape and material of the high-voltage electrode of an atmospheric pressure plasma generation system were optimised. The research was performed with the goal of achieving maximum uniformity of plasma treatment of the surface of the low-voltage electrode with a diameter of 100 mm. In order to generate low-temperature plasma with the volume of roughly 1 cubic decimetre, a pulsed volume discharge was used initiated with a corona discharge. The uniformity of the plasma in the region of the low-voltage electrode was assessed using a system for measuring the distribution of discharge current density. The system's low-voltage electrode - collector - was a disc of 100 mm in diameter, the conducting surface of which was divided into 64 radially located segments of equal surface area. The current at each segment was registered by a high-speed measuring system controlled by an ARM™-based 32-bit microcontroller. To facilitate the interpretation of results obtained, a computer program was developed to visualise the results. The program provides a 3D image of the current density distribution on the surface of the low-voltage electrode. Based on the results obtained an optimum shape for a high-voltage electrode was determined. Uniformity of the distribution of discharge current density in relation to distance between electrodes was studied. It was proven that the level of non-uniformity of current density distribution depends on the size of the gap between electrodes. Experiments indicated that it is advantageous to use graphite felt VGN-6 (Russian abbreviation) as the material of the high-voltage electrode's emitting surface. (paper)

  10. Large Magnetoresistance at High Bias Voltage in Double-layer Organic Spin Valves

    Science.gov (United States)

    Subedi, R. C.; Liang, S. H.; Geng, R.; Zhang, Q. T.; Lou, L.; Wang, J.; Han, X. F.; Nguyen, T. D.

    We report studies of magnetoresistance (MR) in double-layer organic spin valves (DOSV) using tris (8-hydroxyquinolinato) aluminum (Alq3) spacers. The device exhibits three distinct resistance levels depending on the relative magnetizations of the ferromagnetic electrodes. We observed a much weaker bias voltage dependence of MR in the device compared to that in the conventional organic spin valve (OSV). The MR magnitude reduces by the factor of two at 0.7 V bias voltage in the DOSV compared to 0.02 V in the conventional OSV. Remarkably, the MR magnitude reaches 0.3% at 6 V bias in the DOSVs, the largest MR response ever reported in OSVs at this bias. Our finding may have a significant impact on achieving high efficient bipolar OSVs strictly performed at high voltages. University of Georgia start-up fund, Ministry of Education, Singapore, National Natural Science Foundation of China.

  11. Multiple High Voltage Pulse Stressing of Polymer Thick Film Resistors

    Directory of Open Access Journals (Sweden)

    Busi Rambabu

    2014-01-01

    Full Text Available The purpose of this paper is to study high voltage interactions in polymer thick film resistors, namely, polyvinyl chloride- (PVC- graphite thick film resistors, and their applications in universal trimming of these resistors. High voltages in the form of impulses for various pulse durations and with different amplitudes have been applied to polymer thick film resistors and we observed the variation of resistance of these resistors with high voltages. It has been found that the resistance of polymer thick film resistors decreases in the case of higher resistivity materials and the resistance of polymer thick film resistor increases in the case of lower resistivity materials when high voltage impulses are applied to them. It has been also found that multiple high voltage pulse (MHVP stressing can be used to trim the polymer thick film resistors either upwards or downwards.

  12. Low cost photomultiplier high-voltage readout system

    International Nuclear Information System (INIS)

    Oxoby, G.J.; Kunz, P.F.

    1976-10-01

    The Large Aperture Solenoid Spectrometer (LASS) at Stanford Linear Accelerator Center (SLAC) requires monitoring over 300 voltages. This data is recorded on magnetic tapes along with the event data. It must also be displayed so that operators can easily monitor and adjust the voltages. A low-cost high-voltage readout system has been implemented to offer stand-alone digital readout capability as well as fast data transfer to a host computer. The system is flexible enough to permit use of a DVM or ADC and commercially available analogue multiplexers

  13. Design & Fabrication of a High-Voltage Photovoltaic Cell

    Energy Technology Data Exchange (ETDEWEB)

    Felder, Jennifer; /North Carolina State U. /SLAC

    2012-09-05

    Silicon photovoltaic (PV) cells are alternative energy sources that are important in sustainable power generation. Currently, applications of PV cells are limited by the low output voltage and somewhat low efficiency of such devices. In light of this fact, this project investigates the possibility of fabricating high-voltage PV cells on float-zone silicon wafers having output voltages ranging from 50 V to 2000 V. Three designs with different geometries of diffusion layers were simulated and compared in terms of metal coverage, recombination, built-in potential, and conduction current density. One design was then chosen and optimized to be implemented in the final device design. The results of the simulation serve as a feasibility test for the design concept and provide supportive evidence of the effectiveness of silicon PV cells as high-voltage power supplies.

  14. Does the expansion of German high voltage power supply system imply health risks?; Geht vom Ausbau elektrischer Hochspannungsleitungen eine Gefahr fuer die menschliche Gesundheit aus?

    Energy Technology Data Exchange (ETDEWEB)

    Kappos, Andreas D.

    2016-07-01

    The decision of the German parliament to gradually close down nuclear power plants mainly located in the south of Germany and to support wind farms in the North Sea mud flats as the dominant regenerative energy source requires the strengthening and enlargement of the power supply system with the installation of new long distance high voltage power lines. The legally fixed dimension and formality of the actual planning process are discussed as well as the legal regulations for the protection of human health. Guided by the assessment of IARC a ''possible'' carcinogenic effect of low frequency electromagnetic fields on people living in the vicinity of high voltage power lines has to be considered. Therefore from a preventive viewpoint the minimal distance of 400 m between newly planned high voltage power lines and human settlements required by law seem justified.

  15. Phonons and colossal thermal expansion behavior of Ag3Co(CN)6 and Ag3Fe(CN)6.

    Science.gov (United States)

    Mittal, R; Zbiri, M; Schober, H; Achary, S N; Tyagi, A K; Chaplot, S L

    2012-12-19

    Recently colossal volume thermal expansion has been observed in the framework compounds Ag(3)Co(CN)(6) and Ag(3)Fe(CN)(6). We have measured phonon spectra using neutron time-of-flight spectroscopy as a function of temperature and pressure. Ab initio calculations were carried out for the sake of analysis and interpretation. Bonding is found to be very similar in the two compounds. At ambient pressure, modes in the intermediate frequency part of the vibrational spectra in the Co compound are shifted slightly to higher energies as compared to the Fe compound. The temperature dependence of the phonon spectra gives evidence for a large explicit anharmonic contribution to the total anharmonicity for low-energy modes below 5 meV. We have found that modes are mainly affected by the change in size of the unit cell, which in turn changes the bond lengths and vibrational frequencies. Thermal expansion has been calculated via the volume dependence of phonon spectra. Our analysis indicates that Ag phonon modes within the energy range 2-5 meV are strongly anharmonic and major contributors to thermal expansion in both systems. The application of pressure hardens the low-energy part of the phonon spectra involving Ag vibrations and confirms the highly anharmonic nature of these modes.

  16. Integrated differential high-voltage transmitting circuit for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Farch, Kjartan

    2015-01-01

    In this paper an integrated differential high-voltage transmitting circuit for capacitive micromachined ultrasonic transducers (CMUTs) used in portable ultrasound scanners is designed and implemented in a 0.35 μm high-voltage process. Measurements are performed on the integrated circuit in order...... to assess its performance. The circuit generates pulses at differential voltage levels of 60V, 80V and 100 V, a frequency up to 5MHz and a measured driving strength of 1.75 V/ns with the CMUT connected. The total on-chip area occupied by the transmitting circuit is 0.18 mm2 and the power consumption...

  17. High-voltage pulse generator synchronous with LINAC

    International Nuclear Information System (INIS)

    Muto, M.; Hiratsuka, Yoshio; Niimura, Nobuo

    1974-01-01

    High-voltage pulse generator (H.V. Flip-Flop) No.2, an improved type of No.1, is described, which is used in the structural analysis of transient phenomena in materials through the neutron TOF with a Linac. The method of producing positive and negative high-voltage pulses synchronous with the Linac is identical with that in No.1. However, No.2 has outstanding features as follows: (1) The rise time of output pulses is reduced to 0.3 msec, due to the improvement of switching circuit and the winding of a step-up transformer; (2) The widths of positive and negative pulses are variable up to maximum 8 and 16 frames, respectively (One frame = 10 msec); (3) The distribution of TOF signals from a BF 3 counter to a time analyzer is possible even in the negative voltage duration. The panel is provided with the switches for choosing pulse width and the frame for analysis, as well as the dials for setting positive/negative pulse voltage values and the respective indicating meters. (Mori, K)

  18. Electrochemical Properties of the LiNi0.6Co0.2Mn0.2O2 Cathode Material Modified by Lithium Tungstate under High Voltage.

    Science.gov (United States)

    Fu, Jiale; Mu, Daobin; Wu, Borong; Bi, Jiaying; Cui, Hui; Yang, Hao; Wu, Hanfeng; Wu, Feng

    2018-05-31

    An amount (5 wt %) of lithium tungstate (Li 2 WO 4 ) as an additive significantly improves the cycle and rate performances of the LiNi 0.6 Co 0.2 Mn 0.2 O 2 electrode at the cutoff voltage of 4.6 V. The 5 wt % Li 2 WO 4 -mixed LiNi 0.6 Co 0.2 Mn 0.2 O 2 electrode delivers a reversible capacity of 199.2 mA h g -1 and keeps 73.1% capacity for 200 cycles at 1 C. It retains 67.4% capacity after 200 cycles at 2 C and delivers a discharge capacity of 167.3 mA h g -1 at 10 C, while those of the pristine electrode are only 44.7% and 87.5 mA h g -1 , respectively. It is shown that the structure of the LiNi 0.6 Co 0.2 Mn 0.2 O 2 cathode material is not affected by mixing Li 2 WO 4 . The introduced Li 2 WO 4 effectively restrains the LiPF 6 and carbonate solvent decomposition by consuming PF 5 at high cutoff voltage, forming a stable cathode/electrolyte interface film with low resistance.

  19. Streamer propagation velocity to anode and to cathode in He, Xe, N2 and SF6

    International Nuclear Information System (INIS)

    Yakovlenko, S.I.

    2004-01-01

    One studied mechanism of ionization propagation in a solid gas associated with propagation of background electrons in heterogenous electric field. The mentioned mechanism does not depend on the sign of field projection on ionization propagation direction. One derived analytical expression for ionization front rate. The mentioned expression conforms well with numerical calculations. Dependence of wave ionization front rate as a function of a field intensity on boundary of streamer for He, Xe, N 2 and SF 6 is tabulated [ru

  20. 30 CFR 18.54 - High-voltage continuous mining machines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage continuous mining machines. 18.54... and Design Requirements § 18.54 High-voltage continuous mining machines. (a) Separation of high... ground. (e) Onboard ungrounded, three-phase power circuit. A continuous mining machine designed with an...

  1. High-voltage many-pulses generator with inductive energy store and fuse

    International Nuclear Information System (INIS)

    Kovalev, V.P.; Diyankov, V.S.; Kormilitsin, A.I.; Lavrent'ev, B.N.

    1996-01-01

    The high-voltage generator with inductive energy store and fuses as opening switch that generate series of powerful pulses is considered. This generator differs from the ordinary generator with inductive store by the cross-section of the series copper wires. The parameters of the wires are chosen based on empirical relations. The generation principle was tested on the two high-voltage generators with characteristic impedance 2.2 ohm, 4 ohm and with output voltages of 140 kV and 420 kV, respectively. Copper wires 0.1 to 0.23 mm in diameter were used. Series of 2 to 5 pulses of 100 to 300 ns duration, 400 to 1000 kV amplitude and 1 - 10 GW power were obtained. Pulses can be both the same and different. Two successive bremsstrahlung radiation pulses were obtain on the EMIR-M and IGUR-3 devices. Series power megavolt pulses can be generated with a power exceeding 10 11 W, pulse duration of 10 -3 to 10 -6 s, and time interval between them 10 -7 to 10 -5 s. (author). 4 figs., 2 refs

  2. High magnetic field measurement utilizing Faraday rotation in SF11 glass in simplified diagnostics.

    Science.gov (United States)

    Dey, Premananda; Shukla, Rohit; Venkateswarlu, D

    2017-04-01

    With the commercialization of powerful solid-state lasers as pointer lasers, it is becoming simpler nowadays for the launch and free-space reception of polarized light for polarimetric applications. Additionally, because of the high power of such laser diodes, the alignment of the received light on the small sensor area of a photo-diode with a high bandwidth response is also greatly simplified. A plastic sheet polarizer taken from spectacles of 3D television (commercially available) is simply implemented as an analyzer before the photo-receiver. SF11 glass is used as a magneto-optic modulating medium for the measurement of the magnetic field. A magnetic field of magnitude more than 8 Tesla, generated by a solenoid has been measured using this simple assembly. The measured Verdet constant of 12.46 rad/T-m is obtained at the wavelength of 672 nm for the SF11 glass. The complete measurement system is a cost-effective solution.

  3. Intracellular distribution of TM4SF1 and internalization of TM4SF1-antibody complex in vascular endothelial cells

    International Nuclear Information System (INIS)

    Sciuto, Tracey E.; Merley, Anne; Lin, Chi-Iou; Richardson, Douglas; Liu, Yu; Li, Dan; Dvorak, Ann M.; Dvorak, Harold F.; Jaminet, Shou-Ching S.

    2015-01-01

    Transmembrane-4 L-six family member-1 (TM4SF1) is a small plasma membrane-associated glycoprotein that is highly and selectively expressed on the plasma membranes of tumor cells, cultured endothelial cells, and, in vivo, on tumor-associated endothelium. Immunofluorescence microscopy also demonstrated TM4SF1 in cytoplasm and, tentatively, within nuclei. With monoclonal antibody 8G4, and the finer resolution afforded by immuno-nanogold transmission electron microscopy, we now demonstrate TM4SF1 in uncoated cytoplasmic vesicles, nuclear pores and nucleoplasm. Because of its prominent surface location on tumor cells and tumor-associated endothelium, TM4SF1 has potential as a dual therapeutic target using an antibody drug conjugate (ADC) approach. For ADC to be successful, antibodies reacting with cell surface antigens must be internalized for delivery of associated toxins to intracellular targets. We now report that 8G4 is efficiently taken up into cultured endothelial cells by uncoated vesicles in a dynamin-dependent, clathrin-independent manner. It is then transported along microtubules through the cytoplasm and passes through nuclear pores into the nucleus. These findings validate TM4SF1 as an attractive candidate for cancer therapy with antibody-bound toxins that have the capacity to react with either cytoplasmic or nuclear targets in tumor cells or tumor-associated vascular endothelium. - Highlights: • Anti-TM4SF1 antibody 8G4 was efficiently taken up by cultured endothelial cells. • TM4SF1–8G4 internalization is dynamin-dependent but clathrin-independent. • TM4SF1–8G4 complexes internalize along microtubules to reach the perinuclear region. • Internalized TM4SF1–8G4 complexes pass through nuclear pores into the nucleus. • TM4SF1 is an attractive candidate for ADC cancer therapy

  4. Intracellular distribution of TM4SF1 and internalization of TM4SF1-antibody complex in vascular endothelial cells

    Energy Technology Data Exchange (ETDEWEB)

    Sciuto, Tracey E.; Merley, Anne; Lin, Chi-Iou [Center for Vascular Biology Research and Department of Pathology, Beth Israel Deaconess Medical Center and Harvard Medical School (United States); Richardson, Douglas [Department of Molecular and Cellular Biology, Harvard University (United States); Liu, Yu [Department of Pharmacology, Shanxi Medical University, Xinjiannanlu 56, Shanxi Province, Taiyuan 030001 (China); Li, Dan; Dvorak, Ann M. [Center for Vascular Biology Research and Department of Pathology, Beth Israel Deaconess Medical Center and Harvard Medical School (United States); Dvorak, Harold F., E-mail: hdvorak@bidmc.harvard.edu [Center for Vascular Biology Research and Department of Pathology, Beth Israel Deaconess Medical Center and Harvard Medical School (United States); Jaminet, Shou-Ching S., E-mail: sjaminet@bidmc.harvard.edu [Center for Vascular Biology Research and Department of Pathology, Beth Israel Deaconess Medical Center and Harvard Medical School (United States)

    2015-09-25

    Transmembrane-4 L-six family member-1 (TM4SF1) is a small plasma membrane-associated glycoprotein that is highly and selectively expressed on the plasma membranes of tumor cells, cultured endothelial cells, and, in vivo, on tumor-associated endothelium. Immunofluorescence microscopy also demonstrated TM4SF1 in cytoplasm and, tentatively, within nuclei. With monoclonal antibody 8G4, and the finer resolution afforded by immuno-nanogold transmission electron microscopy, we now demonstrate TM4SF1 in uncoated cytoplasmic vesicles, nuclear pores and nucleoplasm. Because of its prominent surface location on tumor cells and tumor-associated endothelium, TM4SF1 has potential as a dual therapeutic target using an antibody drug conjugate (ADC) approach. For ADC to be successful, antibodies reacting with cell surface antigens must be internalized for delivery of associated toxins to intracellular targets. We now report that 8G4 is efficiently taken up into cultured endothelial cells by uncoated vesicles in a dynamin-dependent, clathrin-independent manner. It is then transported along microtubules through the cytoplasm and passes through nuclear pores into the nucleus. These findings validate TM4SF1 as an attractive candidate for cancer therapy with antibody-bound toxins that have the capacity to react with either cytoplasmic or nuclear targets in tumor cells or tumor-associated vascular endothelium. - Highlights: • Anti-TM4SF1 antibody 8G4 was efficiently taken up by cultured endothelial cells. • TM4SF1–8G4 internalization is dynamin-dependent but clathrin-independent. • TM4SF1–8G4 complexes internalize along microtubules to reach the perinuclear region. • Internalized TM4SF1–8G4 complexes pass through nuclear pores into the nucleus. • TM4SF1 is an attractive candidate for ADC cancer therapy.

  5. High-Voltage, Low-Power BNC Feedthrough Terminator

    Science.gov (United States)

    Bearden, Douglas

    2012-01-01

    This innovation is a high-voltage, lowpower BNC (Bayonet Neill-Concelman) feedthrough that enables the user to terminate an instrumentation cable properly while connected to a high voltage, without the use of a voltage divider. This feedthrough is low power, which will not load the source, and will properly terminate the instrumentation cable to the instrumentation, even if the cable impedance is not constant. The Space Shuttle Program had a requirement to measure voltage transients on the orbiter bus through the Ground Lightning Measurement System (GLMS). This measurement has a bandwidth requirement of 1 MHz. The GLMS voltage measurement is connected to the orbiter through a DC panel. The DC panel is connected to the bus through a nonuniform cable that is approximately 75 ft (approximately equal to 23 m) long. A 15-ft (approximately equal to 5-m), 50-ohm triaxial cable is connected between the DC panel and the digitizer. Based on calculations and simulations, cable resonances and reflections due to mismatched impedances of the cable connecting the orbiter bus and the digitizer causes the output not to reflect accurately what is on the bus. A voltage divider at the DC panel, and terminating the 50-ohm cable properly, would eliminate this issue. Due to implementation issues, an alternative design was needed to terminate the cable properly without the use of a voltage divider. Analysis shows how the cable resonances and reflections due to the mismatched impedances of the cable connecting the orbiter bus and the digitizer causes the output not to reflect accurately what is on the bus. After simulating a dampening circuit located at the digitizer, simulations were performed to show how the cable resonances were dampened and the accuracy was improved significantly. Test cables built to verify simulations were accurate. Since the dampening circuit is low power, it can be packaged in a BNC feedthrough.

  6. High-Capacity Cathode Material with High Voltage for Li-Ion Batteries.

    Science.gov (United States)

    Shi, Ji-Lei; Xiao, Dong-Dong; Ge, Mingyuan; Yu, Xiqian; Chu, Yong; Huang, Xiaojing; Zhang, Xu-Dong; Yin, Ya-Xia; Yang, Xiao-Qing; Guo, Yu-Guo; Gu, Lin; Wan, Li-Jun

    2018-03-01

    Electrochemical energy storage devices with a high energy density are an important technology in modern society, especially for electric vehicles. The most effective approach to improve the energy density of batteries is to search for high-capacity electrode materials. According to the concept of energy quality, a high-voltage battery delivers a highly useful energy, thus providing a new insight to improve energy density. Based on this concept, a novel and successful strategy to increase the energy density and energy quality by increasing the discharge voltage of cathode materials and preserving high capacity is proposed. The proposal is realized in high-capacity Li-rich cathode materials. The average discharge voltage is increased from 3.5 to 3.8 V by increasing the nickel content and applying a simple after-treatment, and the specific energy is improved from 912 to 1033 Wh kg -1 . The current work provides an insightful universal principle for developing, designing, and screening electrode materials for high energy density and energy quality. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Second auto-SCT for treatment of relapsed multiple myeloma.

    Science.gov (United States)

    Gonsalves, W I; Gertz, M A; Lacy, M Q; Dispenzieri, A; Hayman, S R; Buadi, F K; Dingli, D; Hogan, W J; Kumar, S K

    2013-04-01

    High-dose therapy and auto-SCT remain integral in the initial treatment of multiple myeloma (MM), and are increasingly being applied for management of relapsed disease. We examined the outcomes in 98 patients undergoing salvage auto-SCT (auto-SCT2) for relapsed MM after receiving an initial transplant (auto-SCT1) between 1994 and 2009. The median age at auto-SCT2 was 60 years (range: 35-74). The median time between auto-SCT1 and auto-SCT2 was 46 months (range: 10-130). Treatment-related mortality was seen in 4%. The median PFS from auto-SCT2 was 10.3 (95% confidence interval (CI): 7-14) months and the median OS from auto-SCT2 was 33 months (95% CI: 28-51). In a multivariable analysis, shorter time to progression (TTP) after auto-SCT1, not achieving a CR after auto-SCT2, higher number of treatment regimens before auto-SCT2 and a higher plasma cell labeling index at auto-SCT2 predicted for shorter PFS. However, only a shorter TTP after auto-SCT1 predicted for a shorter OS post auto-SCT2. Hence, auto-SCT2 is an effective and feasible therapeutic option for MM patients relapsing after other treatments, especially in patients who had a TTP of at least 12 months after their auto-SCT1.

  8. [Fast separation and analysis of water-soluble vitamins in spinach by capillary electrophoresis with high voltage].

    Science.gov (United States)

    Hu, Xiaoqin; You, Huiyan

    2009-11-01

    In capillary electrophoresis, 0-40 kV (even higher) voltage can be reached by a connecting double-model high voltage power supply. In the article, water-soluble vitamins, VB1, VB2, VB6, VC, calcium D-pantothenate, D-biotin, nicotinic acid and folic acid in vegetable, were separated by using the high voltage power supply under the condition of electrolyte water solution as running buffer. The separation conditions, such as voltage, the concentration of buffer and pH value etc. , were optimized during the experiments. The results showed that eight water-soluble vitamins could be baseline separated in 2.2 min at 40 kV applied voltage, 25 mmol/L sodium tetraborate buffer solution (pH 8.8). The water-soluble vitamins in spinach were quantified and the results were satisfied. The linear correlation coefficients of the water-soluble vitamins ranged from 0.9981 to 0.9999. The detection limits ranged from 0.2 to 0.3 mg/L. The average recoveries ranged from 88.0% to 100.6% with the relative standard deviations (RSD) range of 1.15%-4.13% for the spinach samples.

  9. First high-voltage measurements using Ca{sup +} ions at the ALIVE experiment

    Energy Technology Data Exchange (ETDEWEB)

    König, K., E-mail: kkoenig@ikp.tu-darmstadt.de [Technische Universität Darmstadt, Institut für Kernphysik (Germany); Geppert, Ch. [Universität Mainz, Institut für Kernchemie (Germany); Krämer, J.; Maaß, B. [Technische Universität Darmstadt, Institut für Kernphysik (Germany); Otten, E. W. [Universität Mainz, Institut für Physik (Germany); Ratajczyk, T.; Nörtershäuser, W. [Technische Universität Darmstadt, Institut für Kernphysik (Germany)

    2017-11-15

    Many physics experiments depend on accurate high-voltage measurements to determine for example the exact retardation potential of an electron spectrometer as in the KATRIN experiment or the acceleration voltage of the ions at ISOL facilities. Until now only precision high-voltage dividers can be used to measure voltages up to 65 kV with an accuracy of 1 ppm. However, these dividers need frequent calibration and cross-checking and the direct traceability is not given. In this article we will describe the status of an experiment which aims to measure high voltages using collinear laser spectroscopy and which has the potential to provide a high-voltage standard and hence, a calibration source for precision high-voltage dividers on the 1 ppm level.

  10. High voltage holding in the negative ion sources with cesium deposition

    Energy Technology Data Exchange (ETDEWEB)

    Belchenko, Yu.; Abdrashitov, G.; Ivanov, A.; Sanin, A.; Sotnikov, O., E-mail: O.Z.Sotnikov@inp.nsk.su [Budker Institute of Nuclear Physics, Siberian Branch of Russian Academy of Sciences, Novosibirsk (Russian Federation)

    2016-02-15

    High voltage holding of the large surface-plasma negative ion source with cesium deposition was studied. It was found that heating of ion-optical system electrodes to temperature >100 °C facilitates the source conditioning by high voltage pulses in vacuum and by beam shots. The procedure of electrode conditioning and the data on high-voltage holding in the negative ion source with small cesium seed are described. The mechanism of high voltage holding improvement by depletion of cesium coverage is discussed.

  11. Daikin Advanced Lithium Ion Battery Technology – High Voltage Electrolyte - REVISED

    Energy Technology Data Exchange (ETDEWEB)

    Sunstrom, Joseph [Daikin America, Inc., Orangeburg, NY (United States); Hendershot, Ron E. [Daikin America, Inc., Orangeburg, NY (United States)

    2017-03-06

    An evaluation of high voltage electrolytes which contain fluorochemicals as solvents/additive has been completed with the objective of formulating a safe, stable electrolyte capable of operation to 4.6 V. Stable cycle performance has been demonstrated in LiNi1/3Mn1/3Co1/3O2 (NMC111)/graphite cells to 4.5 V. The ability to operate at high voltage results in significant energy density gain (>30%) which would manifest as longer battery life resulting in higher range for electric vehicles. Alternatively, a higher energy density battery can be made smaller without sacrificing existing energy. In addition, the fluorinated electrolytes examined showed better safety performance when tested in abuse conditions. The results are promising for future advanced battery development for vehicles as well as other applications.

  12. High voltage switches having one or more floating conductor layers

    Science.gov (United States)

    Werne, Roger W.; Sampayan, Stephen; Harris, John Richardson

    2015-11-24

    This patent document discloses high voltage switches that include one or more electrically floating conductor layers that are isolated from one another in the dielectric medium between the top and bottom switch electrodes. The presence of the one or more electrically floating conductor layers between the top and bottom switch electrodes allow the dielectric medium between the top and bottom switch electrodes to exhibit a higher breakdown voltage than the breakdown voltage when the one or more electrically floating conductor layers are not present between the top and bottom switch electrodes. This increased breakdown voltage in the presence of one or more electrically floating conductor layers in a dielectric medium enables the switch to supply a higher voltage for various high voltage circuits and electric systems.

  13. Design status and procurement activities of the High Voltage Deck 1 and Bushing for the ITER Neutral Beam Injector

    Energy Technology Data Exchange (ETDEWEB)

    Boldrin, Marco, E-mail: marco.boldrin@igi.cnr.it [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); De Lorenzi, Antonio [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Decamps, Hans [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Grando, Luca [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Simon, Muriel [Fusion For Energy, c/ Josep Pla 2, 08019 Barcelona (Spain); Toigo, Vanni [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy)

    2013-10-15

    Highlights: ► ITER Neutral Beam Injector includes several non-standard components. ► The design status of the −1 MV{sub dc} HVD1 and Bushing is described. ► The paper reports also on the integrated layout of the two components. ► Preliminary electrostatic and thermal analyses are presented. ► Procurement activities are outlined. -- Abstract: The ITER Neutral Beam Injector (NBI) power supply system includes several non-standard components, whose ratings go beyond the present industrial practice. Two of these items, to be procured by Fusion for Energy, are: 1.A −1 MV{sub dc} air-insulated Faraday cage, called High Voltage Deck 1 (HVD1), hosting the Ion Source and Extractor Power Supplies (ISEPS) and the associated diagnostics. 2.A −1 MV{sub dc} feedthrough, called HVD1-TL Bushing, aimed at connecting the HVD1 to the gas (SF{sub 6}) insulated Transmission Line (TL), containing inside its High Voltage (HV) conductor all ISEPS power and control cables coming from the HVD1 to be connected to the NBI Ion Source services. The paper deals with the status of the design of the HVD1 and HVD1-TL Bushing, focusing on insulation, mechanical and thermal issues as well as on their integration with the other components of the power supply system. In particular, the insulation issue of the integrated system has been addressed by means of an electrostatic Finite Element (FE) analysis whilst a FE thermal simulation has been carried out to assess the impact of the dissipation of the proposed design of the inner conductors (ISEPS conductors) not actively cooled. Finally, the paper describes the status of procurement strategy and execution.

  14. Inactivation of Gram-Negative Bacteria by Low-Pressure RF Remote Plasma Excited in N2-O2 Mixture and SF6 Gases

    Directory of Open Access Journals (Sweden)

    Ayman Al-Mariri

    2013-12-01

    Full Text Available The role of low-pressure RF plasma in the inactivation of Escherichia coli O157, Klebsiella pneumoniae, Proteus mirabilis, and Enterobacter sakazakii using N2-O2 and SF6 gases was assessed. 1×109 colony-forming units (CFUs of each bacterial isolate were placed on three polymer foils. The effects of pressure, power, distance from the source, and exposure time to plasma gases were optimized. The best conditions to inactivate the four bacteria were a 91%N2-9%O2 mixture and a 30-minute exposure time. SF6 gas was more efficient for all the tested isolates in as much as the treatment time was reduced to only three minutes. Therefore, low-pressure plasma could be used to sterilize heat and/or moisture-sensitive medical instruments.

  15. A compact, all solid-state LC high voltage generator.

    Science.gov (United States)

    Fan, Xuliang; Liu, Jinliang

    2013-06-01

    LC generator is widely applied in the field of high voltage generation technology. A compact and all solid-state LC high voltage generator based on saturable pulse transformer is proposed in this paper. First, working principle of the generator is presented. Theoretical analysis and circuit simulation are used to verify the design of the generator. Experimental studies of the proposed LC generator with two-stage main energy storage capacitors are carried out. And the results show that the proposed LC generator operates as expected. When the isolation inductance is 27 μH, the output voltage is 1.9 times larger than the charging voltage on single capacitor. The multiplication of voltages is achieved. On the condition that the primary energy storage capacitor is charged to 857 V, the output voltage of the generator can reach to 59.5 kV. The step-up ratio is nearly 69. When self breakdown gas gap switch is used as main switch, the rise time of the voltage pulse on load resistor is 8.7 ns. It means that the series-wound inductance in the discharging circuit is very small in this system. This generator can be employed in two different applications.

  16. Recycling potential for low voltage and high voltage high rupturing capacity fuse links.

    Science.gov (United States)

    Psomopoulos, Constantinos S; Barkas, Dimitrios A; Kaminaris, Stavros D; Ioannidis, George C; Karagiannopoulos, Panagiotis

    2017-12-01

    Low voltage and high voltage high-rupturing-capacity fuse links are used in LV and HV installations respectively, protecting mainly the LV and HV electricity distribution and transportation networks. The Waste Electrical and Electronic Equipment Directive (2002/96/EC) for "Waste of electrical and electronic equipment" is the main related legislation and as it concerns electrical and electronic equipment, it includes electric fuses. Although, the fuse links consist of recyclable materials, only small scale actions have been implemented for their recycling around Europe. This work presents the possibilities for material recovery from this specialized industrial waste for which there are only limited volume data. Furthermore, in order to present the huge possibilities and environmental benefits, it presents the potential for recycling of HRC fuses used by the Public Power Corporation of Greece, which is the major consumer for the country, but one of the smallest ones in Europe and globally, emphasizing in this way in the issue. According to the obtained results, fuse recycling could contribute to the effort for minimize the impacts on the environment through materials recovery and reduction of the wastes' volume disposed of in landfills. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Thermal expansion and lattice parameters of shaped metal deposited Ti-6Al-4V

    Energy Technology Data Exchange (ETDEWEB)

    Swarnakar, Akhilesh Kumar; Van der Biest, Omer [Katholieke Universiteit Leuven, MTM, Kasteelpark Arenberg 44, 3001 Leuven (Belgium); Baufeld, Bernd, E-mail: b.baufeld@sheffield.ac.uk [Katholieke Universiteit Leuven, MTM, Kasteelpark Arenberg 44, 3001 Leuven (Belgium)

    2011-02-10

    Research highlights: > Measurement of thermal expansion and of the lattice parameters of Ti-6Al-4V fabricated by shaped metal deposition up to 1100 {sup o}C. > The observation of alpha to beta transformation not reflected in the expansion but in the contraction curve is explained by non-equilibrium alpha phase of the SMD material. > Denuding of the {alpha} phase and enrichment of the {beta} phase of Vanadium due to high temperature experiments. > The unit cell volumes derived from lattice parameters measured by X-ray diffraction are at room temperature larger for the {alpha} than for the {beta} phase. With increasing temperature the unit cell volume of the {beta} phase increases stronger than the one of the {alpha} phase resulting in a similar unit cell volume at the {beta} transus temperature. - Abstract: Thermal expansion and lattice parameters are investigated up to 1100 deg. C for Ti-6Al-4V components, fabricated by shaped metal deposition. This is a novel additive layer manufacturing technique where near net-shape components are built by tungsten inert gas welding. The as-fabricated SMD Ti-6Al-4V components exhibit a constant coefficient of thermal expansion of 1.17 x 10{sup -5} K{sup -1} during heating up to 1100 {sup o}C, not reflecting the {alpha} to {beta} phase transformation. During cooling a stalling of the contraction is observed starting at the {beta} transus temperature. These high temperature experiments denude the {alpha} phase of V and enrich the {beta} phase. The development of the lattice parameters in dependence on temperature are observed with high temperature X-ray diffraction. The unit cell volumes derived from these parameters are at room temperature larger for the {alpha} than for the {beta} phase. With increasing temperature the unit cell volume of the {beta} phase increases stronger than the one of the {alpha} phase resulting in a similar unit cell volume at the {beta} transus temperature. These observations are interpreted as an

  18. Characterization of a pulsed mode high voltage power supply for nuclear detectors

    International Nuclear Information System (INIS)

    Ghazali, A B; Ahmad, T S; Abdullah, N A

    2013-01-01

    This paper discusses the characterization of a pulsed mode high voltage power supply (HVPS) using LT1073 chip. The pulsed modulated signal generated from this chip is amplified using a step-up ferrite core transformer of 1:20 turn ratio and then further multiplied and converted into DC high voltage output using a diode-capacitor arrangement. The circuit is powered by a 9V alkaline battery but regulated at 5V supply. It was found that the output for this setup is 520V, 87 μA with 10% load regulation. This output is suitable to operate a pancake-type GM detector, typically model LND 7317 where the plateau is from 475V to 675V. It was also found that when a β-source with intensity of 120 cps is used, the power consumption of the circuit is 5 V, 10.1 mA only. When the battery was left 'on' for 40 hours continuously, the battery's voltage has dropped to 6.9V, meaning that the 5V supply as well as 520V output is still maintained. It is noted that the minimum output voltage of 475V has reached when the regulated supply has reduced to 4.6V and consequently the 9V battery dropped to 6.5V, and this had happened after approximately 3 days of continuous operation. The power efficiency for this circuitry was found to be 89.5%. This result has far better in performance since the commercial portable equipment of this type has normally specified that not less than 8 hours continuous operation only. On the circuit design for this power supply, it was found that the enveloped frequency is 133 Hz with approximately 50% duty cycle. The modulated frequency during 'on' state was found to be 256 KHz in which the majority of power consumption is required.

  19. 30 CFR 18.53 - High-voltage longwall mining systems.

    Science.gov (United States)

    2010-07-01

    ...-starter enclosure, with the exception of a controller on a high-voltage shearer, the disconnect device...) shielding between the primary and secondary windings. The shielding must be connected to equipment ground by... with a disconnect device installed to deenergize all high-voltage power conductors extending from the...

  20. Correlations between transmembrane 4 L6 family member 5 (TM4SF5, CD151, and CD63 in liver fibrotic phenotypes and hepatic migration and invasive capacities.

    Directory of Open Access Journals (Sweden)

    Minkyung Kang

    Full Text Available Transmembrane 4 L6 family member 5 (TM4SF5 is overexpressed during CCl4-mediated murine liver fibrosis and in human hepatocellular carcinomas. The tetraspanins form tetraspanin-enriched microdomains (TEMs consisting of large membrane protein complexes on the cell surface. Thus, TM4SF5 may be involved in the signal coordination that controls liver malignancy. We investigated the relationship between TM4SF5-positive TEMs with liver fibrosis and tumorigenesis, using normal Chang hepatocytes that lack TM4SF5 expression and chronically TGFβ1-treated Chang cells that express TM4SF5. TM4SF5 expression is positively correlated with tumorigenic CD151 expression, but is negatively correlated with tumor-suppressive CD63 expression in mouse fibrotic and human hepatic carcinoma tissues, indicating cooperative roles of the tetraspanins in liver malignancies. Although CD151 did not control the expression of TM4SF5, TM4SF5 appeared to control the expression levels of CD151 and CD63. TM4SF5 interacted with CD151, and caused the internalization of CD63 from the cell surface into late lysosomal membranes, presumably leading to terminating the tumor-suppressive functions of CD63. TM4SF5 could overcome the tumorigenic effects of CD151, especially cell migration and extracellular matrix (ECM-degradation. Taken together, TM4SF5 appears to play a role in liver malignancy by controlling the levels of tetraspanins on the cell surface, and could provide a promising therapeutic target for the treatment of liver malignancies.

  1. Square-Wave Voltage Injection Algorithm for PMSM Position Sensorless Control With High Robustness to Voltage Errors

    DEFF Research Database (Denmark)

    Ni, Ronggang; Xu, Dianguo; Blaabjerg, Frede

    2017-01-01

    relationship with the magnetic field distortion. Position estimation errors caused by higher order harmonic inductances and voltage harmonics generated by the SVPWM are also discussed. Both simulations and experiments are carried out based on a commercial PMSM to verify the superiority of the proposed method......Rotor position estimated with high-frequency (HF) voltage injection methods can be distorted by voltage errors due to inverter nonlinearities, motor resistance, and rotational voltage drops, etc. This paper proposes an improved HF square-wave voltage injection algorithm, which is robust to voltage...... errors without any compensations meanwhile has less fluctuation in the position estimation error. The average position estimation error is investigated based on the analysis of phase harmonic inductances, and deduced in the form of the phase shift of the second-order harmonic inductances to derive its...

  2. 30 CFR 75.705-2 - Repairs to energized surface high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Repairs to energized surface high-voltage lines... Repairs to energized surface high-voltage lines. An energized high-voltage surface line may be repaired... on power circuits with a phase-to-phase nominal voltage no greater than 15,000 volts; (3) Such...

  3. Planning aspects of ac extra high voltage lines

    Energy Technology Data Exchange (ETDEWEB)

    Engelhardt, H

    1964-01-01

    The technical points arising in any project for application of higher voltages on power grids in Europe are discussed. The cost aspects of two alternative ways of extending the voltage level of existing systems are discussed in detail. The short-circuit current in a high-power system with isolated or grounded neutral point and its relation to the mode of grounding is examined. For a transmission distance of 200 kVm, operating cost for each kWh transmitted are shown on curves for voltages of 220, 380 and 700 kV against transmitted energy. This shows that for any rated voltage there is a range of energy values which can be transmitted economically. Factors to be considered in maintaining, selecting or rejecting transformers and switchgear of other systems for higher voltage purposes are mentioned.

  4. Insulation co-ordination in high-voltage electric power systems

    CERN Document Server

    Diesendorf, W

    2015-01-01

    Insulation Co-ordination in High-Voltage Electric Power Systems deals with the methods of insulation needed in different circumstances. The book covers topics such as overvoltages and lightning surges; disruptive discharge and withstand voltages; self-restoring and non-self-restoring insulation; lightning overvoltages on transmission lines; and the attenuation and distortion of lightning surges. Also covered in the book are topics such as the switching surge designs of transmission lines, as well as the insulation coordination of high-voltage stations. The text is recommended for electrical en

  5. Reducing methods of patients exposed dose using auto exposure control system in digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Seong Gyu [Dept. of Diagnostic Radiology, Dong A University Medical Center, Busan (Korea, Republic of)

    2013-06-15

    This study was carried out to reduce patient dose through focus-detector distance, kilovoltage, and a combination of copper filters. In the C, L-spine lateral, Skull AP views were obtained by making changes of 60-100 kV in tube voltage and of 100-200 cm in focus-detector distance and by adding a copper filter when using an auto exposure control device in the digital radiography equipment. The incident dose showed 90 kV, 0.3 mmCu in C-spine lateral with 0.06 mGy under the condition of 200 cm; 100 kV, 0.3 mmCu with 0.40 mGy under the condition of 200 cm and 90 kV 0.3 mmCu in Skull AP with the lowest value of 0.24 mGy under the condition of 140 cm. It was observed that entrance surface dose decreased the most when was increased by 150 cm, 70 kV (C-spine lateral), 81 kV (L-spine lateral). It was also found out that as the between the focus-detector increased in the expansion of the video decreased but the difference was not significant when the distance was 180 cm or more. Skull AP showed the most reduction in the entrance surface dose when the tube voltage was changed by 80 kV, 0.1 mmCu, and 120 cm. Therefore, when using the automatic exposure control device, it is recommended to use the highest tube voltage if possible and to increase focus-detector distance at least by 150-200 cm in wall and 120-140 cm in table in consideration of the radiotechnologist's physical conditions, and to combine 0.1-0.3 mmCu and higher filters. It is thus expected to reduce patient dose by avoiding distortion of images and reducing the entrance surface dose.

  6. Analysis of transistor and snubber turn-off dynamics in high-frequency high-voltage high-power converters

    Science.gov (United States)

    Wilson, P. M.; Wilson, T. G.; Owen, H. A., Jr.

    Dc to dc converters which operate reliably and efficiently at switching frequencies high enough to effect substantial reductions in the size and weight of converter energy storage elements are studied. A two winding current or voltage stepup (buck boost) dc-to-dc converter power stage submodule designed to operate in the 2.5-kW range, with an input voltage range of 110 to 180 V dc, and an output voltage of 250 V dc is emphasized. In order to assess the limitations of present day component and circuit technologies, a design goal switching frequency of 10 kHz was maintained. The converter design requirements represent a unique combination of high frequency, high voltage, and high power operation. The turn off dynamics of the primary circuit power switching transistor and its associated turn off snubber circuitry are investigated.

  7. A phase II study of V-BEAM as conditioning regimen before second auto-SCT for multiple myeloma.

    Science.gov (United States)

    Wang, T-F; Fiala, M A; Cashen, A F; Uy, G L; Abboud, C N; Fletcher, T; Wu, N; Westervelt, P; DiPersio, J F; Stockerl-Goldstein, K E; Vij, R

    2014-11-01

    High-dose melphalan has been the standard conditioning regimen for auto-SCT in multiple myeloma (MM) for decades. A more effective conditioning regimen may induce deeper responses and longer remission duration. It is especially needed in the setting of second auto-SCT, which rarely achieves comparable results with the first auto-SCT using the same conditioning regimen. Here we conducted a phase II study to investigate the efficacy and safety of a conditioning regimen V-BEAM (bortezomib-BEAM) before second auto-SCT for multiple myeloma. Ten patients were enrolled from September 2012 to May 2013. The CR rate at day +100 after auto-SCT was 75%; all except for one patient remained in remission after a median follow-up of 6 months. Three patients developed Clostridium difficile infection. Two patients died within the first 30 days of auto-SCT from neutropenic colitis and overwhelming sepsis, respectively. Due to the high rate of morbidity and mortality, the study was terminated after 10 patients. In summary, although the conditioning regimen V-BEAM before second auto-SCT for MM provided promising responses, it was associated with unexpected treatment-related toxicity and should not be investigated further without modifications.

  8. Ground potential rise on the high voltage substation during lightning strike measurement and simulation results

    Energy Technology Data Exchange (ETDEWEB)

    Wiater, Jaroslaw [Bialystok Technical University (Poland). Electrical Dept.], E-mail: jaroslawwiater@we.pb.edu.pl

    2007-07-01

    This paper will present a ground potential rise (GPR) measurement results. All measurements were made during normal work of the real high voltage substation and according a special procedure developed for this occasion. This procedure does not influence on the protection relays and ensures a proper work of the substation even for 6 kV surges. During measurements current and voltage surges were produced by the impulse generator - UCS 500M6B. Measurement results are compared to simulation results performed in CDEGS software for the same initial conditions. (author)

  9. Quantitative studies of transfer in vivo of low density, Sf 12-60, and Sf 60-400 lipoproteins between plasma and arterial intima in humans

    International Nuclear Information System (INIS)

    Shaikh, M.; Wootton, R.; Nordestgaard, B.G.; Baskerville, P.; Lumley, J.S.; La Ville, A.E.; Quiney, J.; Lewis, B.

    1991-01-01

    To assess the potential of various plasma lipoprotein classes to contribute to the lipid content of the arterial intima, influx and efflux of these plasma lipoprotein fractions into and from the intima of human carotid arteries were measured in vivo. While low density lipoprotein (LDL) is known to transfer from plasma into the arterial wall, there is less information on the atherogenic potential of lipoproteins of intermediate density (Sf 12-60) or of very low density (Sf 60-400). Aliquots of the same lipoprotein (LDL, Sf 12-60 lipoprotein particles, or Sf 60-400 lipoprotein particles) iodinated with iodine-125 and iodine-131 were injected intravenously 18-29 hours and 3-6 hours, respectively, before elective surgical removal of atheromatous arterial tissue, and the intimal clearance of lipoproteins, lipoprotein influx, and fractional loss of newly entered lipoproteins were calculated. Intimal clearance of Sf 60-400 particles was not detectable (less than 0.3 microliter x hr-1 x cm-2), whereas the average value for both LDL and Sf 12-60 lipoprotein particles was 0.9 microliter x hr-1 x cm-2. Since the fractional loss of newly entered LDL and Sf 12-60 lipoprotein particles was also similar, the results suggest similar modes of entry and exit for these two particles. However, due to lower plasma concentrations of Sf 12-60 lipoproteins as compared with LDL, the mass influx of cholesterol in the Sf 12-60 particles was on the order of one 10th of that in LDL, and that of apolipoprotein B was about one 20th

  10. High Input Voltage, Silicon Carbide Power Processing Unit Performance Demonstration

    Science.gov (United States)

    Bozak, Karin E.; Pinero, Luis R.; Scheidegger, Robert J.; Aulisio, Michael V.; Gonzalez, Marcelo C.; Birchenough, Arthur G.

    2015-01-01

    A silicon carbide brassboard power processing unit has been developed by the NASA Glenn Research Center in Cleveland, Ohio. The power processing unit operates from two sources: a nominal 300 Volt high voltage input bus and a nominal 28 Volt low voltage input bus. The design of the power processing unit includes four low voltage, low power auxiliary supplies, and two parallel 7.5 kilowatt (kW) discharge power supplies that are capable of providing up to 15 kilowatts of total power at 300 to 500 Volts (V) to the thruster. Additionally, the unit contains a housekeeping supply, high voltage input filter, low voltage input filter, and master control board, such that the complete brassboard unit is capable of operating a 12.5 kilowatt Hall effect thruster. The performance of the unit was characterized under both ambient and thermal vacuum test conditions, and the results demonstrate exceptional performance with full power efficiencies exceeding 97%. The unit was also tested with a 12.5kW Hall effect thruster to verify compatibility and output filter specifications. With space-qualified silicon carbide or similar high voltage, high efficiency power devices, this would provide a design solution to address the need for high power electric propulsion systems.

  11. THREE-DIMENSIONAL OBSERVATIONS ON THICK BIOLOGICAL SPECIMENS BY HIGH VOLTAGE ELECTRON MICROSCOPY

    Directory of Open Access Journals (Sweden)

    Tetsuji Nagata

    2011-05-01

    Full Text Available Thick biological specimens prepared as whole mount cultured cells or thick sections from embedded tissues were stained with histochemical reactions, such as thiamine pyrophosphatase, glucose-6-phosphatase, cytochrome oxidase, acid phosphatase, DAB reactions and radioautography, to observe 3-D ultrastructures of cell organelles producing stereo-pairs by high voltage electron microscopy at accerelating voltages of 400-1000 kV. The organelles demonstrated were Golgi apparatus, endoplasmic reticulum, mitochondria, lysosomes, peroxisomes, pinocytotic vesicles and incorporations of radioactive compounds. As the results, those cell organelles were observed 3- dimensionally and the relative relationships between these organelles were demonstrated.

  12. Evaluation of stratospheric age of air from CF4, C2F6, C3F8, CHF3, HFC-125, HFC-227ea and SF6; implications for the calculations of halocarbon lifetimes, fractional release factors and ozone depletion potentials

    Science.gov (United States)

    Leedham Elvidge, Emma; Bönisch, Harald; Brenninkmeijer, Carl A. M.; Engel, Andreas; Fraser, Paul J.; Gallacher, Eileen; Langenfelds, Ray; Mühle, Jens; Oram, David E.; Ray, Eric A.; Ridley, Anna R.; Röckmann, Thomas; Sturges, William T.; Weiss, Ray F.; Laube, Johannes C.

    2018-03-01

    In a changing climate, potential stratospheric circulation changes require long-term monitoring. Stratospheric trace gas measurements are often used as a proxy for stratospheric circulation changes via the mean age of air values derived from them. In this study, we investigated five potential age of air tracers - the perfluorocarbons CF4, C2F6 and C3F8 and the hydrofluorocarbons CHF3 (HFC-23) and HFC-125 - and compare them to the traditional tracer SF6 and a (relatively) shorter-lived species, HFC-227ea. A detailed uncertainty analysis was performed on mean ages derived from these new tracers to allow us to confidently compare their efficacy as age tracers to the existing tracer, SF6. Our results showed that uncertainties associated with the mean age derived from these new age tracers are similar to those derived from SF6, suggesting that these alternative compounds are suitable in this respect for use as age tracers. Independent verification of the suitability of these age tracers is provided by a comparison between samples analysed at the University of East Anglia and the Scripps Institution of Oceanography. All five tracers give younger mean ages than SF6, a discrepancy that increases with increasing mean age. Our findings qualitatively support recent work that suggests that the stratospheric lifetime of SF6 is significantly less than the previous estimate of 3200 years. The impact of these younger mean ages on three policy-relevant parameters - stratospheric lifetimes, fractional release factors (FRFs) and ozone depletion potentials - is investigated in combination with a recently improved methodology to calculate FRFs. Updates to previous estimations for these parameters are provided.

  13. A low knee voltage and high breakdown voltage of 4H-SiC TSBS employing poly-Si/Ni Schottky scheme

    Science.gov (United States)

    Kim, Dong Young; Seok, Ogyun; Park, Himchan; Bahng, Wook; Kim, Hyoung Woo; Park, Ki Cheol

    2018-02-01

    We report a low knee voltage and high breakdown voltage 4H-SiC TSBS employing poly-Si/Ni dual Schottky contacts. A knee voltage was significantly improved from 0.75 to 0.48 V by utilizing an alternative low work-function material of poly-Si as an anode electrode. Also, reverse breakdown voltage was successfully improved from 901 to 1154 V due to a shrunk low-work-function Schottky region by a proposed self-align etching process between poly-Si and SiC. SiC TSBS with poly-Si/Ni dual Schottky scheme is a suitable structure for high-efficiency rectification and high-voltage blocking operation.

  14. X-ray spectral meter of high voltages for X-ray apparatuses

    International Nuclear Information System (INIS)

    Zubkov, I.P.; Larchikov, Yu.V.

    1993-01-01

    Design of the X-ray spectral meter of high voltages (XRSMHV) for medical X-ray apparatuses permitting to conduct the voltage measurements without connection to current circuits. The XRSMHV consists of two main units: the detector unit based on semiconductor detector and the LP4900B multichannel analyzer (Afora, Finland). The XRSMYV was tested using the pilot plant based on RUM-20 X-ray diagnostic apparatus with high-voltage regulator. It was shown that the developed XRSMHV could be certify in the range of high constant voltages form 40 up to 120 kV with the basic relative error limits ±0.15%. The XRSMHV is used at present as the reference means for calibration of high-voltage medical X-ray equipment

  15. An implantable neurostimulator with an integrated high-voltage inductive power-recovery frontend

    International Nuclear Information System (INIS)

    Wang Yuan; Zhang Xu; Liu Ming; Li Peng; Chen Hongda

    2014-01-01

    This paper present a highly-integrated neurostimulator with an on-chip inductive power-recovery frontend and high-voltage stimulus generator. In particular, the power-recovery frontend includes a high-voltage full-wave rectifier (up to 100 V AC input), high-voltage series regulators (24/5 V outputs) and a linear regulator (1.8/3.3 V output) with bandgap voltage reference. With the high voltage output of the series regulator, the proposed neurostimulator could deliver a considerably large current in high electrode-tissue contact impedance. This neurostimulator has been fabricated in a CSMC 1 μm 5/40/700 V BCD process and the total silicon area including pads is 5.8 mm 2 . Preliminary tests are successful as the neurostimulator shows good stability under a 13.56 MHz AC supply. Compared to previously reported works, our design has advantages of a wide induced voltage range (26–100 V), high output voltage (up to 24 V) and high-level integration, which are suitable for implantable neurostimulators. (semiconductor integrated circuits)

  16. High voltage diagnostics on electrical insulation of supersonducting magnets

    International Nuclear Information System (INIS)

    Irmisch, M.

    1995-12-01

    The high voltage (HV) performance of superconducting magnets of large dimensions, e.g. as needed in fusion reactors, is a challange in the field of high voltage technology, i.e. especially in the field of cryogenic high voltage components and with respect to questions of HV insulation diagnostics at low temperature. By using the development of POLO - a superconducting prototype coil of a tokamak poloidal field coil - as an example, this work deals with special problems of how to get use of conventional HV test techniques for diagnostics under special cryogenic boundary conditions. As a first approach to gain experience in the field of phase resolved partial discharge (PRPD) measurements during operation of a superconductive coil, the POLO coil was subject to several high voltage tests. Compared with DC insulation resistance measurements and capacitive impulse voltage discharges to the coil, the AC PD measurements have been the only way to observe special characteristics of the electrical insulation with respect to the cooling down of the coil from 300 K to 4.2 K. The PRPD measurement technique thereby has proofed as a suitable diagnostic tool. This work can serve as basic data to be comparable within further projects of electrical insulation diagnostics at cryogenic temperatures. (orig.)

  17. Simplifying the free-radical polymerization of styrene : microwave-assisted high-temperature auto polymerizations

    NARCIS (Netherlands)

    Erdmenger, T.; Becer, C.R.; Hoogenboom, R.; Schubert, U.S.

    2009-01-01

    We have investigated the combination of the thermally auto-initiated free radical polymn. of styrene and pptn. polymn. in order to develop a fast and environmentally friendly approach to produce polystyrene. To achieve high reaction temps. in a short period of time, microwave irradn. was utilized as

  18. Precision High-Voltage DC Dividers and Their Calibration

    Czech Academy of Sciences Publication Activity Database

    Dragounová, Naděžda

    2005-01-01

    Roč. 54, č. 5 (2005), s. 1911-1915 ISSN 0018-9456 R&D Projects: GA AV ČR KSK1048102; GA ČR GA202/03/0889 Keywords : calibration * dc voltage * high voltage (HV) Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.665, year: 2005

  19. A HIGH CURRENT, HIGH VOLTAGE SOLID-STATE PULSE GENERATOR FOR THE NIF PLASMA ELECTRODE POCKELS CELL

    International Nuclear Information System (INIS)

    Arnold, P A; Barbosa, F; Cook, E G; Hickman, B C; Akana, G L; Brooksby, C A

    2007-01-01

    A high current, high voltage, all solid-state pulse modulator has been developed for use in the Plasma Electrode Pockels Cell (PEPC) subsystem in the National Ignition Facility. The MOSFET-switched pulse generator, designed to be a more capable plug-in replacement for the thyratron-switched units currently deployed in NIF, offers unprecedented capabilities including burst-mode operation, pulse width agility and a steady-state pulse repetition frequency exceeding 1 Hz. Capable of delivering requisite fast risetime, 17 kV flattop pulses into a 6 (Omega) load, the pulser employs a modular architecture characteristic of the inductive adder technology, pioneered at LLNL for use in acceleration applications, which keeps primary voltages low (and well within the capabilities of existing FET technology), reduces fabrication costs and is amenable to rapid assembly and quick field repairs

  20. Process engineering of high voltage alginate encapsulation of mesenchymal stem cells

    International Nuclear Information System (INIS)

    Gryshkov, Oleksandr; Pogozhykh, Denys; Zernetsch, Holger; Hofmann, Nicola; Mueller, Thomas; Glasmacher, Birgit

    2014-01-01

    Encapsulation of stem cells in alginate beads is promising as a sophisticated drug delivery system in treatment of a wide range of acute and chronic diseases. However, common use of air flow encapsulation of cells in alginate beads fails to produce beads with narrow size distribution, intact spherical structure and controllable sizes that can be scaled up. Here we show that high voltage encapsulation (≥ 15 kV) can be used to reproducibly generate spherical alginate beads (200–400 μm) with narrow size distribution (± 5–7%) in a controlled manner under optimized process parameters. Flow rate of alginate solution ranged from 0.5 to 10 ml/h allowed producing alginate beads with a size of 320 and 350 μm respectively, suggesting that this approach can be scaled up. Moreover, we found that applied voltages (15–25 kV) did not alter the viability and proliferation of encapsulated mesenchymal stem cells post-encapsulation and cryopreservation as compared to air flow. We are the first who employed a comparative analysis of electro-spraying and air flow encapsulation to study the effect of high voltage on alginate encapsulated cells. This report provides background in application of high voltage to encapsulate living cells for further medical purposes. Long-term comparison and work on alginate–cell interaction within these structures will be forthcoming. - Highlights: • High voltage alginate encapsulation of mesenchymal stem cells (MSCs) was designed. • Reproducible and spherical alginate beads were generated via high voltage. • Air flow encapsulation was utilized as a comparative approach to high voltage. • High voltage did not alter the viability and proliferation of encapsulated MSCs. • High voltage encapsulation can be scaled up and applied in cell-based therapy

  1. High-voltage many-pulses generator with inductive energy store and fuse

    Energy Technology Data Exchange (ETDEWEB)

    Kovalev, V P; Diyankov, V S; Kormilitsin, A I; Lavrent` ev, B N [All-Russian Research Inst. of Technical Physics, Snezhinsk (Russian Federation)

    1997-12-31

    The high-voltage generator with inductive energy store and fuses as opening switch that generate series of powerful pulses is considered. This generator differs from the ordinary generator with inductive store by the cross-section of the series copper wires. The parameters of the wires are chosen based on empirical relations. The generation principle was tested on the two high-voltage generators with characteristic impedance 2.2 ohm, 4 ohm and with output voltages of 140 kV and 420 kV, respectively. Copper wires 0.1 to 0.23 mm in diameter were used. Series of 2 to 5 pulses of 100 to 300 ns duration, 400 to 1000 kV amplitude and 1 - 10 GW power were obtained. Pulses can be both the same and different. Two successive bremsstrahlung radiation pulses were obtain on the EMIR-M and IGUR-3 devices. Series power megavolt pulses can be generated with a power exceeding 10{sup 11} W, pulse duration of 10{sup -3} to 10{sup -6} s, and time interval between them 10{sup -7} to 10{sup -5} s. (author). 4 figs., 2 refs.

  2. High voltage power network construction

    CERN Document Server

    Harker, Keith

    2018-01-01

    This book examines the key requirements, considerations, complexities and constraints relevant to the task of high voltage power network construction, from design, finance, contracts and project management to installation and commissioning, with the aim of providing an overview of the holistic end to end construction task in a single volume.

  3. High Bandwidth Zero Voltage Injection Method for Sensorless Control of PMSM

    DEFF Research Database (Denmark)

    Ge, Xie; Lu, Kaiyuan; Kumar, Dwivedi Sanjeet

    2014-01-01

    High frequency signal injection is widely used in PMSM sensorless control system for low speed operations. The conventional voltage injection method often needs filters to obtain particular harmonic component in order to estimate the rotor position; or it requires several voltage pulses to be inj......High frequency signal injection is widely used in PMSM sensorless control system for low speed operations. The conventional voltage injection method often needs filters to obtain particular harmonic component in order to estimate the rotor position; or it requires several voltage pulses...... in a fast current regulation performance. Injection of zero voltage also minimizes the inverter voltage error effects caused by the dead-time....

  4. Auto-inducing media for uniform isotope labeling of proteins with 15N, 13C and 2H

    International Nuclear Information System (INIS)

    Guthertz, Nicolas; Klopp, Julia; Winterhalter, Aurélie; Fernández, César; Gossert, Alvar D.

    2015-01-01

    Auto-inducing media for protein expression offer many advantages like robust reproducibility, high yields of soluble protein and much reduced workload. Here, an auto-inducing medium for uniform isotope labelling of proteins with 15 N, 13 C and/or 2 H in E. coli is presented. So far, auto-inducing media have not found widespread application in the NMR field, because of the prohibitively high cost of labeled lactose, which is an essential ingredient of such media. Here, we propose using lactose that is only selectively labeled on the glucose moiety. It can be synthesized from inexpensive and readily available substrates: labeled glucose and unlabeled activated galactose. With this approach, uniformly isotope labeled proteins were expressed in unattended auto-inducing cultures with incorporation of 13 C, 15 N of 96.6 % and 2 H, 15 N of 98.8 %. With the present protocol, the NMR community could profit from the many advantages that auto-inducing media offer

  5. Characteristics and Breakdown Behaviors of Polysilicon Resistors for High Voltage Applications

    Directory of Open Access Journals (Sweden)

    Xiao-Yu Tang

    2015-01-01

    Full Text Available With the rapid development of the power integrated circuit technology, polysilicon resistors have been widely used not only in traditional CMOS circuits, but also in the high voltage applications. However, there have been few detailed reports about the polysilicon resistors’ characteristics, like voltage and temperature coefficients and breakdown behaviors which are critical parameters of high voltage applications. In this study, we experimentally find that the resistance of the polysilicon resistor with a relatively low doping concentration shows negative voltage and temperature coefficients, while that of the polysilicon resistor with a high doping concentration has positive voltage and temperature coefficients. Moreover, from the experimental results of breakdown voltages of the polysilicon resistors, it could be deduced that the breakdown of polysilicon resistors is thermally rather than electrically induced. We also proposed to add an N-type well underneath the oxide to increase the breakdown voltage in the vertical direction when the substrate is P-type doped.

  6. Digitally Programmable High-Q Voltage Mode Universal Filter

    Directory of Open Access Journals (Sweden)

    D. Singh

    2013-12-01

    Full Text Available A new low-voltage low-power CMOS current feedback amplifier (CFA is presented in this paper. This is used to realize a novel digitally programmable CFA (DPCFA using transistor arrays and MOS switches. The proposed realizations nearly allow rail-to-rail swing capability at all the ports. Class-AB output stage ensures low power dissipation and high current drive capability. The proposed CFA/ DPCFA operates at supply voltage of ±0.75 V and exhibits bandwidth better than 95 MHz. An application of the DPCFA to realize a novel voltage mode high-Q digitally programmable universal filter (UF is given. Performances of all the proposed circuits are verified by PSPICE simulation using TSMC 0.25μm technology parameters.

  7. Thermal expansion behaviour of high performance PEEK matrix composites

    International Nuclear Information System (INIS)

    Goyal, R K; Mulik, U P; Tiwari, A N; Negi, Y S

    2008-01-01

    The thermal expansion behaviour of high performance poly(ether-ether-ketone) (PEEK) composites reinforced with micro- (8 μm) and nano- (39 nm) sized Al 2 O 3 particles was studied. The distribution of Al 2 O 3 in the PEEK matrix was studied by scanning electron microscopy and transmission electron microscopy. The coefficient of thermal expansion (CTE) was reduced from 58 x 10 -6 deg. C -1 for pure PEEK to 22 x 10 -6 deg. C -1 at 43 vol% micro-Al 2 O 3 and to 23 x 10 -6 deg. C -1 at 12 vol% nano-Al 2 O 3 composites. For a given volume fraction, nano-Al 2 O 3 particles are more effective in reducing the CTE of composites than that of micro-Al 2 O 3 particles. This may be attributed to the much higher interfacial area or volume of nanocomposites than that of microcomposites. The upper limit and lower limit of the Schapery model separately fit closely the CTE of the micro- and nano-composites, respectively. Other models such as the rule of mixture and Kerner and Turner models were also correlated with the data

  8. Auto Safety

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Auto Safety KidsHealth / For Parents / Auto Safety What's in this ... by teaching some basic rules. Importance of Child Safety Seats Using a child safety seat (car seat) ...

  9. Evaluation of the high-voltage high-frequency transformer insulating materials for satellites

    International Nuclear Information System (INIS)

    Kurita, Hiroshi; Hasegawa, Taketoshi; Hirasawa, Eiichi; Gonai, Toshio; Ohsuga, Hiroyuki.

    1987-01-01

    Environment resistance evaluation was made of the insulating materials of impregnated injection type for high-voltage high-frequency transformers mounted in satellites. (1) The stress occurring in the impregnated injection type resin is small in silicon resin and urethane resin and large in epoxy resin. (2) The dielectric characteristic at high frequency is good in silicone resin. In epoxy resin, when the transformer is operated at high temperature, its thermal runaway may take place. (3) The radiation deterioration at 1 Mrad - 10 Mrad is slight in urethane resin. (4) The degassing is not good in silicone resin. (5) The adhesive power is good in urethane resin. (6) From the above results, in silicone resin there is problem in degassing and adhesive power. In epoxy resin there is problem in stress and dielectric characteristic. (Mori, K.)

  10. 30 CFR 75.802 - Protection of high-voltage circuits extending underground.

    Science.gov (United States)

    2010-07-01

    ...-Voltage Distribution § 75.802 Protection of high-voltage circuits extending underground. (a) Except as... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection of high-voltage circuits extending... which shall be grounded through a suitable resistor at the source transformers, and a grounding circuit...

  11. Copper wire theft and high voltage electrical burns

    OpenAIRE

    Francis, Eamon C; Shelley, Odhran P

    2014-01-01

    High voltage electrical burns are uncommon. However in the midst of our economic recession we are noticing an increasing number of these injuries. Copper wire is a valuable commodity with physical properties as an excellent conductor of electricity making it both ubiquitous in society and prized on the black market. We present two consecutive cases referred to the National Burns Unit who sustained life threatening injuries from the alleged theft of high voltage copper wire and its omnipresenc...

  12. Mechanism of formation of subnanosecond current front in high-voltage pulse open discharge

    Science.gov (United States)

    Schweigert, I. V.; Alexandrov, A. L.; Zakrevsky, Dm. E.; Bokhan, P. A.

    2014-11-01

    The mechanism of subnanosecond current front rise observed previously in the experiment in high-voltage pulse open discharge in helium is studied in kinetic particle-in-cell simulations. The Boltzmann equations for electrons, ions, and fast atoms are solved self-consistently with the Poisson equations for the electrical potential. The partial contributions to the secondary electron emission from the ions, fast atoms, photons, and electrons, bombarding the electrode, are calculated. In simulations, as in the experiment, the discharge glows between two symmetrical cathodes and the anode grid in the midplane at P =6 Torr and the applied voltage of 20 kV. The electron avalanche development is considered for two experimental situations during the last stage of breakdown: (i) with constant voltage and (ii) with decreasing voltage. For case (i), the subnanosecond current front rise is set by photons from the collisional excitation transfer reactions. For the case (ii), the energetic electrons swamp the cathode during voltage drop and provide the secondary electron emission for the subnanosecond current rise, observed in the experiment.

  13. An Integrated Chip High-Voltage Power Receiver for Wireless Biomedical Implants

    Directory of Open Access Journals (Sweden)

    Vijith Vijayakumaran Nair

    2015-06-01

    Full Text Available In near-field wireless-powered biomedical implants, the receiver voltage largely overrides the compliance of low-voltage power receiver systems. To limit the induced voltage, generally, low-voltage topologies utilize limiter circuits, voltage clippers or shunt regulators, which are power-inefficient methods. In order to overcome the voltage limitation and improve power efficiency, we propose an integrated chip high-voltage power receiver based on the step down approach. The topology accommodates voltages as high as 30 V and comprises a high-voltage semi-active rectifier, a voltage reference generator and a series regulator. Further, a battery management circuit that enables safe and reliable implant battery charging based on analog control is proposed and realized. The power receiver is fabricated in 0.35-μm high-voltage Bipolar-CMOS-DMOStechnology based on the LOCOS0.35-μm CMOS process. Measurement results indicate 83.5% power conversion efficiency for a rectifier at 2.1 mA load current. The low drop-out regulator based on the current buffer compensation and buffer impedance attenuation scheme operates with low quiescent current, reduces the power consumption and provides good stability. The topology also provides good power supply rejection, which is adequate for the design application. Measurement results indicate regulator output of 4 ± 0.03 V for input from 5 to 30 V and 10 ± 0.05 V output for input from 11 to 30 V with load current 0.01–100 mA. The charger circuit manages the charging of the Li-ion battery through all if the typical stages of the Li-ion battery charging profile.

  14. Experimental investigation of linear thermal expansion of pyrolytic graphite at high temperatures

    Science.gov (United States)

    Senchenko, V. N.; Belikov, R. S.

    2017-11-01

    Using the previously described [1] experimental setup for investigation of the thermophysical properties of refractory materials under high pressure and temperature a few experiments with pyrolytic graphite were carried out. The density of the material was equal to 2.18 g/cm3. Experimental data on the linear thermal expansion in the perpendicular and parallel to the basal plane direction were obtained. Thermal expansion in the perpendicular to the basal plane direction during the heating from room temperature up to the melting point was 16.4 ± 1.6%. The results obtained allow calculating the density of pyrolytic graphite in the wide range of high temperatures up to the melting point.

  15. AutoCAD 2015 and AutoCAD LT 2015 essentials

    CERN Document Server

    Onstott, Scott

    2014-01-01

    Step-by-step instructions for the AutoCAD fundamentals AutoCAD 2015 Essentials contains 400 pages of full-color, comprehensive instruction on the world's top drafting and architecture software. This 2015 edition features architectural, manufacturing, and landscape architecture examples. And like previous editions, the detailed guide introduces core concepts using interactive tutorials and open-ended projects, which can be completed in any order, thanks to downloadable data sets (an especially useful feature for students and professionals studying for Autodesk AutoCAD certification). Unlike man

  16. Design and development of high voltage and high frequency center tapped transformer for HVDC test generator

    International Nuclear Information System (INIS)

    Thaker, Urmil; Saurabh Kumar; Amal, S.; Baruah, U.K.; Bhatt, Animesh

    2015-01-01

    A High Voltage center tapped transformer for high frequency application had been designed, fabricated, and tested. It was designed as a part of 200 kV HVDC Test Generator. The High Frequency operation of transformer increases power density. Therefore it is possible to reduce power supply volume. The step up ratio in High Voltage transformer is limited due to stray capacitance and leakage inductance. The limit was overcome by winding multi secondary outputs. Switching frequency of transformer was 15.8 kHz. Input and output voltages of transformer were 270V and 16.5kV-0V-16.5kV respectively. Power rating of transformer is 7kVA. High Voltage transformer with various winding and core arrangement was fabricated to check variation in electrical characteristics. The transformer used a ferrite core (E Type) and nylon insulated primary and secondary bobbins. Two set of E-E geometry cores had been stacked in order to achieve the estimated core volume. Compared with traditional high voltage transformer, this transformer had good thermal behavior, good line insulation properties and a high power density. In this poster, design procedures, development stages and test results of high voltage and high frequency transformer are presented. Results of various parameters such as transformer loss, temperature rise, insulation properties, impedance of primary and secondary winding, and voltage regulation are discussed. (author)

  17. Stepwise expansion of the bacteriophage ϕ6 procapsid: possible packaging intermediates.

    Science.gov (United States)

    Nemecek, Daniel; Cheng, Naiqian; Qiao, Jian; Mindich, Leonard; Steven, Alasdair C; Heymann, J Bernard

    2011-11-25

    The initial assembly product of bacteriophage ϕ6, the procapsid, undergoes major structural transformation during the sequential packaging of its three segments of single-stranded RNA. The procapsid, a compact icosahedrally symmetric particle with deeply recessed vertices, expands to the spherical mature capsid, increasing the volume available to accommodate the genome by 2.5-fold. It has been proposed that expansion and packaging are linked, with each stage in expansion presenting a binding site for a particular RNA segment. To investigate procapsid transformability, we induced expansion by acidification, heating, and elevated salt concentration. Cryo-electron microscopy reconstructions after all three treatments yielded the same partially expanded particle. Analysis by cryo-electron tomography showed that all vertices of a given capsid were either in a compact or an expanded state, indicating a highly cooperative transition. To benchmark the mature capsid, we analyzed filled (in vivo packaged) capsids. When these particles were induced to release their RNA, they reverted to the same intermediate state as expanded procapsids (intermediate 1) or to a second, further expanded state (intermediate 2). This partial reversibility of expansion suggests that the mature spherical capsid conformation is obtained only when sufficient outward pressure is exerted by packaged RNA. The observation of two intermediates is consistent with the proposed three-step packaging process. The model is further supported by the observation that a mutant capable of packaging the second RNA segment without previously packaging the first segment has enhanced susceptibility for switching spontaneously from the procapsid to the first intermediate state. Published by Elsevier Ltd.

  18. Advanced High Voltage Power Device Concepts

    CERN Document Server

    Baliga, B Jayant

    2012-01-01

    Advanced High Voltage Power Device Concepts describes devices utilized in power transmission and distribution equipment, and for very high power motor control in electric trains and steel-mills. Since these devices must be capable of supporting more than 5000-volts in the blocking mode, this books covers operation of devices rated at 5,000-V, 10,000-V and 20,000-V. Advanced concepts (the MCT, the BRT, and the EST) that enable MOS-gated control of power thyristor structures are described and analyzed in detail. In addition, detailed analyses of the silicon IGBT, as well as the silicon carbide MOSFET and IGBT, are provided for comparison purposes. Throughout the book, analytical models are generated to give a better understanding of the physics of operation for all the structures. This book provides readers with: The first comprehensive treatment of high voltage (over 5000-volts) power devices suitable for the power distribution, traction, and motor-control markets;  Analytical formulations for all the device ...

  19. Borate electrolyte additives for high voltage lithium nickel manganese oxide electrode: A comparative study

    International Nuclear Information System (INIS)

    Chen, Zhiting; Wang, Cun; Xing, Lidan; Wang, Xianshu; Tu, Wenqiang; Zhu, Yunmin; Li, Weishan

    2017-01-01

    Highlights: •TMB and TEB effective improve the cyclic stability of LNMO at high voltage. •The performance of LNMO with TMB-containing electrolyte is superior to that of TEB. •LNMO shows catalytic effect on the oxidation reaction of TEB. •The film generated in TMB shows better ability on suppressing LNMO shedding than TEB. -- Abstract: Trimethyl borate (TMB) and triethyl borate (TEB) are used as film-forming electrolyte additives for high voltage Lithium nickel manganese oxide (LNMO) cathode. DFT calculation and initial charge curve of LNMO reveal that the oxidation activity of TEB is higher than that of TMB. Addition of 2% TMB and 2% TEB effectively improve the capacity retention of high voltage LNMO from 23.4% to 85.3% and 72.6% after 600 cycles, respectively. The film generated in TMB-containing electrolyte shows better ability on suppressing the LNMO shedding in comparison with that of TEB, resulting in higher capacity retention of LNMO in TMB-containing electrolyte at high voltage. The superior performance of LNMO with TMB-containing electrolyte should be ascribed to its less intense film-forming reaction which generates a denser protective surface film on LNMO surface. However, why LNMO shows catalyzation effect on TEB oxidation but not on TMB is unclear, which needs further intensive investigation.

  20. Auto Body Welding 2 (Course Outline), Automotive Body Repair and Refinishing 1: 9033.04.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    The 90-hour course is a foundation quinmester course in welding for the auto body repairman. The outline consists of seven blocks of instruction (orientation, 6 hours; auto body oxyacetylene welding, 10 hours; electric arc welding equipment, 6 hours; auto body electric arc welding, 8 hours; position welding, 40 hours; electric spot welders, 16…

  1. Copper wire theft and high voltage electrical burns.

    Science.gov (United States)

    Francis, Eamon C; Shelley, Odhran P

    2014-01-01

    High voltage electrical burns are uncommon. However in the midst of our economic recession we are noticing an increasing number of these injuries. Copper wire is a valuable commodity with physical properties as an excellent conductor of electricity making it both ubiquitous in society and prized on the black market. We present two consecutive cases referred to the National Burns Unit who sustained life threatening injuries from the alleged theft of high voltage copper wire and its omnipresence on an international scale.

  2. Asymptotic expansions for high-contrast linear elasticity

    KAUST Repository

    Poveda, Leonardo A.; Huepo, Sebastian; Calo, Victor M.; Galvis, Juan

    2015-01-01

    We study linear elasticity problems with high contrast in the coefficients using asymptotic limits recently introduced. We derive an asymptotic expansion to solve heterogeneous elasticity problems in terms of the contrast in the coefficients. We study the convergence of the expansion in the H1 norm. © 2015 Elsevier B.V.

  3. Asymptotic expansions for high-contrast linear elasticity

    KAUST Repository

    Poveda, Leonardo A.

    2015-03-01

    We study linear elasticity problems with high contrast in the coefficients using asymptotic limits recently introduced. We derive an asymptotic expansion to solve heterogeneous elasticity problems in terms of the contrast in the coefficients. We study the convergence of the expansion in the H1 norm. © 2015 Elsevier B.V.

  4. MOSFET-based high voltage short pulse generator for ultrasonic transducer excitation

    Science.gov (United States)

    Hidayat, Darmawan; Setianto, Syafei, Nendi Suhendi; Wibawa, Bambang Mukti

    2018-02-01

    This paper presents the generation of a high-voltage short pulse for the excitation of high frequency ultrasonic transducers. This is highly required in the purpose of various ultrasonic-based evaluations, particularly when high resolution measurement is necessary. A high voltage (+760 V) DC voltage source was pulsated by an ultrafast switching MOSFET which was driven by a pulse generator circuit consisting of an astable multivibrator, a one-shot multivibrator with Schmitt trigger input and a high current MOSFET driver. The generated pulses excited a 200-kHz and a 1-MHz ultrasonic transducers and tested in the transmission mode propagation to evaluate the performances of the generated pulse. The test results showed the generator were able to produce negative spike pulses up to -760 V voltage with the shortest time-width of 107.1 nanosecond. The transmission-received ultrasonic waves show frequency oscillation at 200 and 961 kHz and their amplitudes varied with the voltage of excitation pulse. These results conclude that the developed pulse generator is applicable to excite transducer for the generation of high frequency ultrasonic waves.

  5. Temperature Stabilized Characterization of High Voltage Power Supplies

    CERN Document Server

    Krarup, Ole

    2017-01-01

    High precision measurements of the masses of nuclear ions in the ISOLTRAP experiment relies on an MR-ToF. A major source of noise and drift is the instability of the high voltage power supplies employed. Electrical noise and temperature changes can broaden peaks in time-of-flight spectra and shift the position of peaks between runs. In this report we investigate how the noise and drift of high-voltage power supplies can be characterized. Results indicate that analog power supplies generally have better relative stability than digitally controlled ones, and that the high temperature coefficients of all power supplies merit efforts to stabilize them.

  6. pVT-Second Virial Coefficients B(T ), Viscosity η(T ), and Self-Diffusion ρD(T) of the Gases: BF3, CF4, SiF4, CCl4, SiCl4, SF6, MoF6, WF6, UF6, C(CH3)4, and Si(CH3)4 Determined by Means of an Isotropic Temperature-Dependent Potential

    Science.gov (United States)

    Zarkova, L.; Hohm, U.

    2002-03-01

    We present results on self-consistent calculations of second pVT-virial coefficients B(T), viscosity data η(T), and diffusion coefficients ρD(T) for eleven heavy globular gases: boron trifluoride (BF3), carbon tetrafluoride (CF4), silicon tetrafluoride (SiF4), carbon tetrachloride (CCl4), silicon tetrachloride (SiCl4), sulfur hexafluoride (SF6), molybdenum hexafluoride (MoF6), tungsten hexafluoride (WF6), uranium hexafluoride (UF6), tetramethyl methane (C(CH3)4, TMM), and tetramethyl silane (Si(CH3)4, TMS). The calculations are performed mainly in the temperature range between 200 and 900 K by means of isotropic n-6 potentials with temperature-dependent separation rm(T) and potential well depth ɛ(T). The potential parameters at T=0 K (ɛ, rm, n) and the enlargement of the first level radii δ are obtained solving an ill-posed problem of minimizing the squared deviations between experimental and calculated values normalized to their relative experimental error. The temperature dependence of the potential is obtained as a result of the influence of vibrational excitation on binary interactions. This concept of the isotropic temperature-dependent potential (ITDP) is presented in detail where gaseous SF6 will serve as an example. The ITDP is subsequently applied to all other gases. This approach and the main part of the results presented here have already been published during 1996-2000. However, in some cases the data are upgraded due to the recently improved software (CF4, SF6) and newly found experimental data (CF4, SiF4, CCl4, SF6).

  7. Voltage regulator for generator

    Energy Technology Data Exchange (ETDEWEB)

    Naoi, K

    1989-01-17

    It is an object of this invention to provide a voltage regulator for a generator charging a battery, wherein even if the ambient temperature at the voltage regulator rises abnormally high, possible thermal breakage of the semiconductor elements constituting the voltage regulator can be avoided. A feature of this invention is that the semiconductor elements can be protected from thermal breakage, even at an abnormal ambient temperature rise at the voltage regulator for the battery charging generator, by controlling a maximum conduction ratio of a power transistor in the voltage regulator in accordance with the temperature at the voltage regulator. This is achieved through a switching device connected in series to the field coil of the generator and adapted to be controlled in accordance with an output voltage of the generator and the ambient temperature at the voltage regulator. 6 figs.

  8. A High Voltage Swing 1.9 GHz PA in Standard CMOS

    NARCIS (Netherlands)

    Aartsen, W.A.J.; Annema, Anne J.; Nauta, Bram

    2002-01-01

    A circuit technique for RF power amplifiers that reliably handle voltage peaks well above the nominal supply voltage is presented. To achieve this high-voltage tolerance the circuit implements switched-cascode transistors that yield reliable operation for voltages up to 7V at RF frequencies in a

  9. High voltage series protection of neutral injectors with crossed-field tubes

    International Nuclear Information System (INIS)

    Hofmann, G.A.; Thomas, D.G.

    1976-01-01

    High voltage neutral beam injectors for fusion machines require either parallel or series protection schemes to limit fault currents in case of arcing to safe levels. The protection device is usually located between the high voltage supply and beam injector and either crowbars (parallel protection) or disconnects (series protection) the high voltage supply when a fault occurs. Because of its isolating property, series protection is preferred. The Hughes crossed-field tube is uniquely suited for series protection schemes. The tube can conduct 40 A continuously upon application of voltage (approximately 300 V) and a static magnetic field (approximately 100 G). It is also capable of interrupting currents of 1000 A within 10 μs and withstand voltage of more than 120 kV. Experiments were performed to simulate the duty of a crossed-field tube as a series protection element in a neutral injector circuit under fault conditions. Results of on-switching tests under high and low voltage and interruption of fault currents are presented. An example of a possible protection circuit with crossed-field tubes is discussed

  10. High-voltage pixel sensors for ATLAS upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Perić, I., E-mail: ivan.peric@ziti.uni-heidelberg.de [Heidelberg University, Institute of Computer Engineering, Mannheim (Germany); Kreidl, C.; Fischer, P. [Heidelberg University, Institute of Computer Engineering, Mannheim (Germany); Bompard, F.; Breugnon, P.; Clemens, J.-C.; Fougeron, D.; Liu, J.; Pangaud, P.; Rozanov, A.; Barbero, M. [CPPM, Marseille (France); Feigl, S.; Capeans, M.; Ferrere, D.; Pernegger, H.; Ristic, B. [CERN, Geneve (Switzerland); Muenstermann, D.; Gonzalez Sevilla, S.; La Rosa, A.; Miucci, A. [University of Geneve (Switzerland); and others

    2014-11-21

    The high-voltage (HV-) CMOS pixel sensors offer several good properties: a fast charge collection by drift, the possibility to implement relatively complex CMOS in-pixel electronics and the compatibility with commercial processes. The sensor element is a deep n-well diode in a p-type substrate. The n-well contains CMOS pixel electronics. The main charge collection mechanism is drift in a shallow, high field region, which leads to a fast charge collection and a high radiation tolerance. We are currently evaluating the use of the high-voltage detectors implemented in 180 nm HV-CMOS technology for the high-luminosity ATLAS upgrade. Our approach is replacing the existing pixel and strip sensors with the CMOS sensors while keeping the presently used readout ASICs. By intelligence we mean the ability of the sensor to recognize a particle hit and generate the address information. In this way we could benefit from the advantages of the HV sensor technology such as lower cost, lower mass, lower operating voltage, smaller pitch, smaller clusters at high incidence angles. Additionally we expect to achieve a radiation hardness necessary for ATLAS upgrade. In order to test the concept, we have designed two HV-CMOS prototypes that can be readout in two ways: using pixel and strip readout chips. In the case of the pixel readout, the connection between HV-CMOS sensor and the readout ASIC can be established capacitively.

  11. Empiric auto-titrating CPAP in people with suspected obstructive sleep apnea.

    Science.gov (United States)

    Drummond, Fitzgerald; Doelken, Peter; Ahmed, Qanta A; Gilbert, Gregory E; Strange, Charlie; Herpel, Laura; Frye, Michael D

    2010-04-15

    Efficient diagnosis and treatment of obstructive sleep apnea (OSA) can be difficult because of time delays imposed by clinic visits and serial overnight polysomnography. In some cases, it may be desirable to initiate treatment for suspected OSA prior to polysomnography. Our objective was to compare the improvement of daytime sleepiness and sleep-related quality of life of patients with high clinical likelihood of having OSA who were randomly assigned to receive empiric auto-titrating continuous positive airway pressure (CPAP) while awaiting polysomnogram versus current usual care. Serial patients referred for overnight polysomnography who had high clinical likelihood of having OSA were randomly assigned to usual care or immediate initiation of auto-titrating CPAP. Epworth Sleepiness Scale (ESS) scores and the Functional Outcomes of Sleep Questionnaire (FOSQ) scores were obtained at baseline, 1 month after randomization, and again after initiation of fixed CPAP in control subjects and after the sleep study in auto-CPAP patients. One hundred nine patients were randomized. Baseline demographics, daytime sleepiness, and sleep-related quality of life scores were similar between groups. One-month ESS and FOSQ scores were improved in the group empirically treated with auto-titrating CPAP. ESS scores improved in the first month by a mean of -3.2 (confidence interval -1.6 to -4.8, p life in a cohort of patients awaiting polysomnography who had a high pretest probability of having OSA. Additional studies are needed to evaluate the applicability of empiric treatment to other populations.

  12. High-voltage short-fall pulse generator

    International Nuclear Information System (INIS)

    Dolbilov, G.V.; Fateev, A.A.; Petrov, V.A.

    1986-01-01

    Powerful high-voltage pulses with short fall times and relatively low afterpulse amplitude are required for the deflection systems of accelerators. A generator is described that provides, into a 75-ohm load, a voltage pulse of up to 100 kV with a fall time of less than 1 nsec and a relative afterpulse amplitude of less than or equal to 15%. The generator employs a short-circuited ferrite-filled line in which shock waves are formed. A magnetic section is used to increase power. The switch is a TGI1-2500/50 thyratron. The main causes of afterpulses and methods for reducing their amplitude are examined

  13. Auto-Baecklund Transformation and Analytic Solutions of (2+1)-Dimensional Boussinesq Equation

    International Nuclear Information System (INIS)

    Liu Guanting

    2008-01-01

    Using the truncated Painleve expansion, symbolic computation, and direct integration technique, we study analytic solutions of (2+1)-dimensional Boussinesq equation. An auto-Baecklund transformation and a number of exact solutions of this equation have been found. The set of solutions include solitary wave solutions, solitoff solutions, and periodic solutions in terms of elliptic Jacobi functions and Weierstrass wp function. Some of them are novel.

  14. Copper wire theft and high voltage electrical burns

    Science.gov (United States)

    Francis, Eamon C; Shelley, Odhran P

    2014-01-01

    High voltage electrical burns are uncommon. However in the midst of our economic recession we are noticing an increasing number of these injuries. Copper wire is a valuable commodity with physical properties as an excellent conductor of electricity making it both ubiquitous in society and prized on the black market. We present two consecutive cases referred to the National Burns Unit who sustained life threatening injuries from the alleged theft of high voltage copper wire and its omnipresence on an international scale. PMID:25356371

  15. Microparticles in high-voltage accelerator tubes

    International Nuclear Information System (INIS)

    Griffith, G.L.; Eastham, D.A.

    1979-01-01

    Microparticles with radii greater than 2 μm have been observed in a high voltage vacuum accelerator tube. The charge acquired by most of the particles is similar to the contact charging of a conducting sphere on a plane. (author)

  16. Study of weld quality real-time monitoring system for auto-body assembly

    Science.gov (United States)

    Xu, Jun; Li, Yong-Bing; Chen, Guan-Long

    2005-12-01

    Resistance spot welding (RSW) is widely used for the auto-body assembly in automotive industry. But RSW suffers from a major problem of inconsistent quality from weld to weld. The major problem is the complexity of the basic process that may involve material coatings, electrode force, electrode wear, fit up, etc. Therefore weld quality assurance is still a big challenge and goal. Electrode displacement has proved to be a particularly useful signal which correlates well with weld quality. This paper introduces a novel auto-body spot weld quality monitoring system which uses electrode displacement as the quality parameter. This system chooses the latest laser displacement sensor with high resolution to measure the real-time electrode displacement. It solves the interference problem of sensor mounting by designing special fixture, and can be successfully applied on the portable welding machine. It is capable of evaluating weld quality and making diagnosis of process variations such as surface asperities, shunting, worn electrode and weld expansion with real-time electrode displacement. As proved by application in the workshop, the monitoring system has good stability and reliability, and is qualified for monitoring weld quality in process.

  17. Thermal expansion studies on Inconel-600[reg] by high temperature X-ray diffraction

    International Nuclear Information System (INIS)

    Raju, S.; Sivasubramanian, K.; Divakar, R.; Panneerselvam, G.; Banerjee, A.; Mohandas, E.; Antony, M.P.

    2004-01-01

    The lattice thermal expansion characteristics of Inconel-600[reg] have been studied by high temperature X-ray diffraction (HT-XRD) technique in the temperature range 298-1200 K. Altogether four experimental runs were conducted on thin foils of about 75-100 μm thickness. The diffraction profiles have been accurately calibrated to offset the shift in 2θ values introduced by sample buckling at elevated temperatures. The corrected lattice parameter data have been used to estimate the instantaneous and mean linear thermal expansion coefficients as a function of temperature. The thermal expansion values estimated in the present study show a fair degree of agreement with other existing dilatometer based bulk thermal expansion estimates. The lattice parameter for this alloy at 300 K is found to be 0.3549(1) nm. The mean linear thermal expansivity is found to be 11.4 x 10 -6 K -1

  18. Snit: SF frem, NA og EL under spærregrænsen

    DEFF Research Database (Denmark)

    Thomsen, Søren Risbjerg

    2008-01-01

    NYHED: SF fortsætter fremgangen, mens såvel NA som EL er røget under spærregrænsen i det nye vejede snit af meningsmålinger. Udgivelsesdato: 6. januar......NYHED: SF fortsætter fremgangen, mens såvel NA som EL er røget under spærregrænsen i det nye vejede snit af meningsmålinger. Udgivelsesdato: 6. januar...

  19. High voltage and high specific capacity dual intercalating electrode Li-ion batteries

    Science.gov (United States)

    West, William C. (Inventor); Blanco, Mario (Inventor)

    2010-01-01

    The present invention provides high capacity and high voltage Li-ion batteries that have a carbonaceous cathode and a nonaqueous electrolyte solution comprising LiF salt and an anion receptor that binds the fluoride ion. The batteries can comprise dual intercalating electrode Li ion batteries. Methods of the present invention use a cathode and electrode pair, wherein each of the electrodes reversibly intercalate ions provided by a LiF salt to make a high voltage and high specific capacity dual intercalating electrode Li-ion battery. The present methods and systems provide high-capacity batteries particularly useful in powering devices where minimizing battery mass is important.

  20. An inverted-geometry, high voltage polarized electron gun with UHV load lock

    International Nuclear Information System (INIS)

    Breidenbach, M.; Foss, M.; Hodgson, J.; Kulikov, A.; Odian, A.; Putallaz, G.; Rogers, H.; Schindler, R.; Skarpaas, K.; Zolotorev, M.

    1994-01-01

    The design of a high voltage electron source with a GaAs photocathode and a load lock system is described. The inverted high voltage structure of the gun permits a compact and simple design. Test results demonstrate that the load lock system provides a reliable way to achieve high quantum efficiency of the photocathode in a high voltage device. ((orig.))

  1. Integrated reconfigurable high-voltage transmitting circuit for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Jørgensen, Ivan Harald Holger

    2015-01-01

    In this paper a high-voltage transmitting circuit aimed for capacitive micromachined ultrasonic transducers (CMUTs) used in scanners for medical applications is designed and implemented in a 0.35 μm high-voltage CMOS process. The transmitting circuit is reconfigurable externally making it able...... to drive a wide variety of CMUTs. The transmitting circuit can generate several pulse shapes with voltages up to 100 V, maximum pulse range of 50 V, frequencies up to 5 MHz and different driving slew rates. Measurements are performed on the circuit in order to assess its functionality and power consumption...... performance. The design occupies an on-chip area of 0.938 mm2 and the power consumption of a 128-element transmitting circuit array that would be used in an portable ultrasound scanner is found to be a maximum of 181 mW....

  2. Correlated physical and mental health summary scores for the SF-36 and SF-12 Health Survey, V.1

    Directory of Open Access Journals (Sweden)

    Cunningham William E

    2007-09-01

    Full Text Available Abstract Background The SF-36 and SF-12 summary scores were derived using an uncorrelated (orthogonal factor solution. We estimate SF-36 and SF-12 summary scores using a correlated (oblique physical and mental health factor model. Methods We administered the SF-36 to 7,093 patients who received medical care from an independent association of 48 physician groups in the western United States. Correlated physical health (PCSc and mental health (MCSc scores were constructed by multiplying each SF-36 scale z-score by its respective scoring coefficient from the obliquely rotated two factor solution. PCSc-12 and MCSc-12 scores were estimated using an approach similar to the one used to derive the original SF-12 summary scores. Results The estimated correlation between SF-36 PCSc and MCSc scores was 0.62. There were far fewer negative factor scoring coefficients for the oblique factor solution compared to the factor scoring coefficients produced by the standard orthogonal factor solution. Similar results were found for PCSc-12, and MCSc-12 summary scores. Conclusion Correlated physical and mental health summary scores for the SF-36 and SF-12 derived from an obliquely rotated factor solution should be used along with the uncorrelated summary scores. The new scoring algorithm can reduce inconsistent results between the SF-36 scale scores and physical and mental health summary scores reported in some prior studies. (Subscripts C = correlated and UC = uncorrelated

  3. Optimal design of a high accuracy photoelectric auto-collimator based on position sensitive detector

    Science.gov (United States)

    Yan, Pei-pei; Yang, Yong-qing; She, Wen-ji; Liu, Kai; Jiang, Kai; Duan, Jing; Shan, Qiusha

    2018-02-01

    A kind of high accuracy Photo-electric auto-collimator based on PSD was designed. The integral structure composed of light source, optical lens group, Position Sensitive Detector (PSD) sensor, and its hardware and software processing system constituted. Telephoto objective optical type is chosen during the designing process, which effectively reduces the length, weight and volume of the optical system, as well as develops simulation-based design and analysis of the auto-collimator optical system. The technical indicators of auto-collimator presented by this paper are: measuring resolution less than 0.05″; a field of view is 2ω=0.4° × 0.4° measuring range is +/-5' error of whole range measurement is less than 0.2″. Measuring distance is 10m, which are applicable to minor-angle precise measuring environment. Aberration analysis indicates that the MTF close to the diffraction limit, the spot in the spot diagram is much smaller than the Airy disk. The total length of the telephoto lens is only 450mm by the design of the optical machine structure optimization. The autocollimator's dimension get compact obviously under the condition of the image quality is guaranteed.

  4. Improved performance of the microbial electrolysis desalination and chemical-production cell with enlarged anode and high applied voltages.

    Science.gov (United States)

    Ye, Bo; Luo, Haiping; Lu, Yaobin; Liu, Guangli; Zhang, Renduo; Li, Xiao

    2017-11-01

    The aim of this study was to improve performance of the microbial electrolysis desalination and chemical-production cell (MEDCC) using enlarged anode and high applied voltages. MEDCCs with anode lengths of 9 and 48cm (i.e., the 9cm-anode MEDCC and 48cm-anode MEDCC, respectively) were tested under different voltages (1.2-3.0V). Our results demonstrated for the first time that the MEDCC could maintain high performance even under the applied voltage higher than that for water dissociation (i.e., 1.8V). Under the applied voltage of 2.5V, the maximum current density in the 48cm-anode MEDCC reached 32.8±2.6A/m 2 , which is one of the highest current densities reported so far in the bioelectrochemical system (BES). The relative abundance of Geobacter was changed along the anode length. Our results show the great potential of the BES with enlarged anode and high applied voltages. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. The research of high voltage switchgear detecting unit

    Science.gov (United States)

    Ji, Tong; Xie, Wei; Wang, Xiaoqing; Zhang, Jinbo

    2017-07-01

    In order to understand the status of the high voltage switch in the whole life circle, you must monitor the mechanical and electrical parameters that affect device health. So this paper gives a new high voltage switchgear detecting unit based on ARM technology. It can measure closing-opening mechanical wave, storage motor current wave and contactor temperature to judge the device’s health status. When something goes wrong, it can be on alert and give some advice. The practice showed that it can meet the requirements of circuit breaker mechanical properties temperature online detection.

  6. High-voltage direct-current circuit breakers

    International Nuclear Information System (INIS)

    Yoshioka, Y.; Hirasawa, K.

    1991-01-01

    This paper reports that in 1954 the first high-voltage direct-current (HVDC) transmission system was put into operation between Gotland and the mainland of Sweden. Its system voltage and capacity were 100 kV and 20 MW, respectively. Since then many HVDC transmission systems have been planned, constructed, or commissioned in more than 30 places worldwide, and their total capacity is close to 40 GW. Most systems commissioned to date are two-terminal schemes, and HVDC breakers are not yet used in the high-potential main circuit of those systems, because the system is expected to perform well using only converter/inverter control even at a fault stage of the transmission line. However, even in a two-terminal scheme there are not a few merits in using an HVDC breaker when the system has two parallel transmission lines, that is, when it is a double-circuit system

  7. Thermal Expansion of Vitrified Blood Vessels Permeated with DP6 and Synthetic Ice Modulators

    Science.gov (United States)

    Eisenberg, David P.; Taylor, Michael J.; Jimenez-Rios, Jorge L.; Rabin, Yoed

    2014-01-01

    This study provides thermal expansion data for blood vessels permeated with the cryoprotective cocktail DP6, when combined with selected synthetic ice modulators (SIMs): 12% polyethylene glycol 400, 6% 1,3-cyclohexanediol, and 6% 2,3-butanediol. The general classification of SIMs includes molecules that modulate ice nucleation and growth, or possess properties of stabilizing the amorphous state, by virtue of their chemical structure and at concentrations that are not explained on a purely colligative basis. The current study is part of an ongoing effort to characterize thermo-mechanical effects on structural integrity of cryopreserved materials, where thermal expansion is the driving mechanism to thermo-mechanical stress. This study focuses on the lower part of the cryogenic temperature range, where the cryoprotective agent (CPA) behaves as a solid for all practical applications. By combining results obtained in the current study with literature data on the thermal expansion in the upper part of the cryogenic temperature range, unified thermal expansion curves are presented. PMID:24769313

  8. High voltage switch triggered by a laser-photocathode subsystem

    Science.gov (United States)

    Chen, Ping; Lundquist, Martin L.; Yu, David U. L.

    2013-01-08

    A spark gap switch for controlling the output of a high voltage pulse from a high voltage source, for example, a capacitor bank or a pulse forming network, to an external load such as a high gradient electron gun, laser, pulsed power accelerator or wide band radar. The combination of a UV laser and a high vacuum quartz cell, in which a photocathode and an anode are installed, is utilized as triggering devices to switch the spark gap from a non-conducting state to a conducting state with low delay and low jitter.

  9. Are decisions using cost-utility analyses robust to choice of SF-36/SF-12 preference-based algorithm?

    Directory of Open Access Journals (Sweden)

    Walton Surrey M

    2005-03-01

    Full Text Available Abstract Background Cost utility analysis (CUA using SF-36/SF-12 data has been facilitated by the development of several preference-based algorithms. The purpose of this study was to illustrate how decision-making could be affected by the choice of preference-based algorithms for the SF-36 and SF-12, and provide some guidance on selecting an appropriate algorithm. Methods Two sets of data were used: (1 a clinical trial of adult asthma patients; and (2 a longitudinal study of post-stroke patients. Incremental costs were assumed to be $2000 per year over standard treatment, and QALY gains realized over a 1-year period. Ten published algorithms were identified, denoted by first author: Brazier (SF-36, Brazier (SF-12, Shmueli, Fryback, Lundberg, Nichol, Franks (3 algorithms, and Lawrence. Incremental cost-utility ratios (ICURs for each algorithm, stated in dollars per quality-adjusted life year ($/QALY, were ranked and compared between datasets. Results In the asthma patients, estimated ICURs ranged from Lawrence's SF-12 algorithm at $30,769/QALY (95% CI: 26,316 to 36,697 to Brazier's SF-36 algorithm at $63,492/QALY (95% CI: 48,780 to 83,333. ICURs for the stroke cohort varied slightly more dramatically. The MEPS-based algorithm by Franks et al. provided the lowest ICUR at $27,972/QALY (95% CI: 20,942 to 41,667. The Fryback and Shmueli algorithms provided ICURs that were greater than $50,000/QALY and did not have confidence intervals that overlapped with most of the other algorithms. The ICUR-based ranking of algorithms was strongly correlated between the asthma and stroke datasets (r = 0.60. Conclusion SF-36/SF-12 preference-based algorithms produced a wide range of ICURs that could potentially lead to different reimbursement decisions. Brazier's SF-36 and SF-12 algorithms have a strong methodological and theoretical basis and tended to generate relatively higher ICUR estimates, considerations that support a preference for these algorithms over the

  10. BEHAVIOUR OF BACKFILL MATERIALS FOR ELECTRICAL GROUNDING SYSTEMS UNDER HIGH VOLTAGE CONDITIONS

    Directory of Open Access Journals (Sweden)

    S. C. LIM

    2015-06-01

    Full Text Available Backfill materials like Bentonite and cement are effective in lowering grounding resistance of electrodes for a considerable period. During lightning, switching impulses and earth fault occurrences in medium and high voltage networks, the grounding system needs to handle extremely high currents either for a short duration or prolonged period respectively. This paper investigates the behaviour of bentonite, cement and sand under impulse and alternating high voltage (50Hz conditions. Fulguritic-formation was observed in all materials under alternating high voltage. The findings reveal that performance of grounding systems under high voltage conditions may significantly change from the outcomes anticipated at design stage.

  11. Non-sparking anodization process of AZ91D magnesium alloy under low AC voltage

    International Nuclear Information System (INIS)

    Li, Weiping; Li, Wen; Zhu, Liqun; Liu, Huicong; Wang, Xiaofang

    2013-01-01

    Highlights: ► Four different processes appear on magnesium alloys with applied voltage increase. ► Non-sparking film formation process occurred in the range of 6–10 V AC. ► The film was composed of Mg 2 SiO 4 with a stable growth rate in 30 min. ► Film growth was a balance of electrochemical dissolution and chemical deposition. -- Abstract: Anodization is widely recognized as one of the most important surface treatments for magnesium alloys. However, since high voltage oxidation films are limited in some applications due to porosity and brittleness, it is worthwhile to explore the non-sparking oxidizing process. In this work, AZ91D was electrochemically anodized at different AC voltages in an electrolyte containing 120 g/L NaOH and 80 g/L Na 2 SiO 3 ·9H 2 O. The effects of voltage on the surface morphology, composition and reaction process, especially the non-sparking discharge anodic film formation process, were investigated. The results showed that four different processes would appear according to the applied voltage variation from 6 V to 40 V, and that the non-sparking film formation process occurred in the range of 6–10 V. The film formed on the AZ91D surface under 10 V AC was mainly composed of Mg 2 SiO 4 with a lamellar structure. The horizontal and vertical expansion of the lamellar structure resulted in the formation of a multi-layered structure with a stable, linear growth rate for 30 min. The non-sparking film formation process can be considered to be the result of a balance of electrochemical dissolution and chemical deposition reaction

  12. 75 FR 20918 - High-Voltage Continuous Mining Machine Standard for Underground Coal Mines

    Science.gov (United States)

    2010-04-22

    ... DEPARTMENT OF LABOR Mine Safety and Health Administration 30 CFR Parts 18 and 75 RIN 1219-AB34 High-Voltage Continuous Mining Machine Standard for Underground Coal Mines Correction In rule document 2010-7309 beginning on page 17529 in the issue of Tuesday, April 6, 2010, make the following correction...

  13. ARCPHdb: A comprehensive protein database for SF1 and SF2 helicase from archaea.

    Science.gov (United States)

    Moukhtar, Mirna; Chaar, Wafi; Abdel-Razzak, Ziad; Khalil, Mohamad; Taha, Samir; Chamieh, Hala

    2017-01-01

    Superfamily 1 and Superfamily 2 helicases, two of the largest helicase protein families, play vital roles in many biological processes including replication, transcription and translation. Study of helicase proteins in the model microorganisms of archaea have largely contributed to the understanding of their function, architecture and assembly. Based on a large phylogenomics approach, we have identified and classified all SF1 and SF2 protein families in ninety five sequenced archaea genomes. Here we developed an online webserver linked to a specialized protein database named ARCPHdb to provide access for SF1 and SF2 helicase families from archaea. ARCPHdb was implemented using MySQL relational database. Web interfaces were developed using Netbeans. Data were stored according to UniProt accession numbers, NCBI Ref Seq ID, PDB IDs and Entrez Databases. A user-friendly interactive web interface has been developed to browse, search and download archaeal helicase protein sequences, their available 3D structure models, and related documentation available in the literature provided by ARCPHdb. The database provides direct links to matching external databases. The ARCPHdb is the first online database to compile all protein information on SF1 and SF2 helicase from archaea in one platform. This database provides essential resource information for all researchers interested in the field. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. High frequency breakdown voltage

    International Nuclear Information System (INIS)

    Chu, Thanh Duy.

    1992-03-01

    This report contains information about the effect of frequency on the breakdown voltage of an air gap at standard pressure and temperature, 76 mm Hg and O degrees C, respectively. The frequencies of interest are 47 MHz and 60 MHz. Additionally, the breakdown in vacuum is briefly considered. The breakdown mechanism is explained on the basis of collision and ionization. The presence of the positive ions produced by ionization enhances the field in the gap, and thus determines the breakdown. When a low-frequency voltage is applied across the gap, the breakdown mechanism is the same as that caused by the DC or static voltage. However, when the frequency exceeds the first critical value f c , the positive ions are trapped in the gap, increasing the field considerably. This makes the breakdown occur earlier; in other words, the breakdown voltage is lowered. As the frequency increases two decades or more, the second critical frequency, f ce , is reached. This time the electrons start being trapped in the gap. Those electrons that travel multiple times across the gap before reaching the positive electrode result in an enormous number of electrons and positive ions being present in the gap. The result is a further decrease of the breakdown voltage. However, increasing the frequency does not decrease the breakdown voltage correspondingly. In fact, the associated breakdown field intensity is almost constant (about 29 kV/cm).The reason is that the recombination rate increases and counterbalances the production rate, thus reducing the effect of the positive ions' concentration in the gap. The theory of collision and ionization does not apply to the breakdown in vacuum. It seems that the breakdown in vacuum is primarily determined by the irregularities on the surfaces of the electrodes. Therefore, the effect of frequency on the breakdown, if any, is of secondary importance

  15. PROMIS PF CAT Outperforms the ODI and SF-36 Physical Function Domain in Spine Patients.

    Science.gov (United States)

    Brodke, Darrel S; Goz, Vadim; Voss, Maren W; Lawrence, Brandon D; Spiker, William Ryan; Hung, Man

    2017-06-15

    The Oswestry Disability Index v2.0 (ODI), SF36 Physical Function Domain (SF-36 PFD), and PROMIS Physical Function CAT v1.2 (PF CAT) questionnaires were prospectively collected from 1607 patients complaining of back or leg pain, visiting a university-based spine clinic. All questionnaires were collected electronically, using a tablet computer. The aim of this study was to compare the psychometric properties of the PROMIS PF CAT with the ODI and SF36 Physical Function Domain in the same patient population. Evidence-based decision-making is improved by using high-quality patient-reported outcomes measures. Prior studies have revealed the shortcomings of the ODI and SF36, commonly used in spine patients. The PROMIS Network has developed measures with excellent psychometric properties. The Physical Function domain, delivered by Computerized Adaptive Testing (PF CAT), performs well in the spine patient population, though to-date direct comparisons with common measures have not been performed. Standard Rasch analysis was performed to directly compare the psychometrics of the PF CAT, ODI, and SF36 PFD. Spearman correlations were computed to examine the correlations of the three instruments. Time required for administration was also recorded. One thousand six hundred seven patients were administered all assessments. The time required to answer all items in the PF CAT, ODI, and SF-36 PFD was 44, 169, and 99 seconds. The ceiling and floor effects were excellent for the PF CAT (0.81%, 3.86%), while the ceiling effects were marginal and floor effects quite poor for the ODI (6.91% and 44.24%) and SF-36 PFD (5.97% and 23.65%). All instruments significantly correlated with each other. The PROMIS PF CAT outperforms the ODI and SF-36 PFD in the spine patient population and is highly correlated. It has better coverage, while taking less time to administer with fewer questions to answer. 2.

  16. High voltage calibration of the TANSY-KM5 neutron detectors

    International Nuclear Information System (INIS)

    Grosshoeg, G.; Belle, P. van; Wilson, D.

    1996-11-01

    We have developed a procedure for the high voltage calibration of the TANSY neutron detectors. The procedure is based on the work done during the construction of the spectrometer. A program is written for the measurement of the sensitivity of the neutron detectors as a function of the high voltage. The data are transferred to a PC for evaluation. We use a Cobalt source for the calibration. With the PC the voltage corresponding to the effective Compton edge is found. The voltage settings for the neutron detectors are calculated and stored in a file suitable for input to a program that is used to control the instrument. A measurement is reported that shows that the reproducibility of the measurement is good. 4 refs

  17. Lithium-Ion Electrolytes with Improved Safety Tolerance to High Voltage Systems

    Science.gov (United States)

    Smart, Marshall C. (Inventor); Bugga, Ratnakumar V. (Inventor); Prakash, Surya G. (Inventor); Krause, Frederick C. (Inventor)

    2015-01-01

    The invention discloses various embodiments of electrolytes for use in lithium-ion batteries, the electrolytes having improved safety and the ability to operate with high capacity anodes and high voltage cathodes. In one embodiment there is provided an electrolyte for use in a lithium-ion battery comprising an anode and a high voltage cathode. The electrolyte has a mixture of a cyclic carbonate of ethylene carbonate (EC) or mono-fluoroethylene carbonate (FEC) co-solvent, ethyl methyl carbonate (EMC), a flame retardant additive, a lithium salt, and an electrolyte additive that improves compatibility and performance of the lithium-ion battery with a high voltage cathode. The lithium-ion battery is charged to a voltage in a range of from about 2.0 V (Volts) to about 5.0 V (Volts).

  18. Thermal and Hygric Expansion of High Performance Concrete

    Directory of Open Access Journals (Sweden)

    J. Toman

    2001-01-01

    Full Text Available The linear thermal expansion coefficient of two types of high performance concrete was measured in the temperature range from 20 °C to 1000 °C, and the linear hygric expansion coefficient was determined in the moisture range from dry material to saturation water content. Comparative methods were applied for measurements of both coefficients. The experimental results show that both the effect of temperature on the values of linear thermal expansion coefficients and the effect of moisture on the values of linear hygric expansion coefficients are very significant and cannot be neglected in practical applications.

  19. Advances in high voltage engineering

    CERN Document Server

    Haddad, A

    2005-01-01

    This book addresses the very latest research and development issues in high voltage technology and is intended as a reference source for researchers and students in the field, specifically covering developments throughout the past decade. This unique blend of expert authors and comprehensive subject coverage means that this book is ideally suited as a reference source for engineers and academics in the field for years to come.

  20. Compact, Lightweight, High Voltage Propellant Isolators, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — TA&T, Inc. proposes an enabling fabrication process for high voltage isolators required in high power solar electric and nuclear electric propulsion (SEP and...