WorldWideScience

Sample records for high-voltage electrical burn

  1. High-voltage electrical burns due to copper theft - Case series.

    Science.gov (United States)

    Braga, M J; Oliveira, I; Egipto, P; Silva, A

    2016-03-31

    Electrical burns are among the most devastating trauma inflicted on the human body. These burns have a higher morbidity, length of stay and a much higher risk of amputation than any other type of burn. Electrical burns affect mostly young, working males because they are more frequently the result of a work accident. However, possibly due to the worldwide economic crisis, we are experiencing a new phenomenon: the theft of high-voltage copper wiring.

  2. High-voltage electrical burns due to copper theft – Case series

    Science.gov (United States)

    Braga, M.J.; Oliveira, I.; Egipto, P.; Silva, A.

    2016-01-01

    Summary Electrical burns are among the most devastating trauma inflicted on the human body. These burns have a higher morbidity, length of stay and a much higher risk of amputation than any other type of burn. Electrical burns affect mostly young, working males because they are more frequently the result of a work accident. However, possibly due to the worldwide economic crisis, we are experiencing a new phenomenon: the theft of high-voltage copper wiring. PMID:27857650

  3. Analysis of predictor factors of limb amputation in patients with high-voltage electrical burns

    Directory of Open Access Journals (Sweden)

    Guillermo García Álvarez

    2015-09-01

    Full Text Available Background: Limb amputation is considered one of the most devastating consequences of electrical injury. Any factors that correlate with the degree of muscle damage can be used to predict the necessity of limb amputation. The aim of this study was to determine the factors that can be used to predict limb amputation in high-voltage electrically injured patients. Methods: Eighty-two high-voltage electrically injured patients were admitted to the Department of Plastic and Reconstructive Surgery and Burns of National Arzobispo Loayza Hospital on a 5 year period. A retrospective analysis of the possible related risk factors between amputation and non-amputation patients was performed. Results: A total of 68 patients were enrolled for analysis. Thirteen patients underwent limb amputations. Multivariate analysis of the risk factors between amputation and non-amputation groups showed statistical significance for first 24 hour creatine kinase-isoenzyme MB (CKMB level. A serum CK-MB level above 14,955 U/L predicted high risk of limb amputation with high specificity (84% and sensitivity (77%. Only one patient with a remarkable decrease of creatine kinase (CPKt and CK-MB levels after fasciotomy avoided a major limb amputation. Conclusion: Our results suggest that CPK-MB level is an independent factor for prediction of limb amputation in patients with high-voltage electrical burns. We suggest that the addition of CPK-MB evaluation to clinical symptom screening may be a valuable method for early detection of muscle damage.

  4. Pyogenic Arthritis of the Ankle Joint Following a High-Voltage Electrical Burn in the Lower Extremity: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kuk Seon; Lee, Gyung Kyu; Kang, Ik Won; Hwang, Dae Hyun; Lee, Eil Seong; Min, Seon Jung; Han, You Mie [Dept. of Radiology, Hangang Scared Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of); Lee, Eil Seong [Dept.of Radiology, Gyeongju Hospital, Dongguk University College of Medicine, Gyeongju (Korea, Republic of)

    2011-04-15

    A high-voltage electrical burn caused extensive deep muscle injuries beneath a relatively small skin wound at the contact point. Hidden, undetected deep muscle injuries have a tendency for progressive tissue necrosis, which can lead to major amputations or sepsis. The radiologic features of this rare, sometimes life-threatening injury have occasionally been described in the literature. However, to the best of our knowledge, there have been no reports on a case of pyogenic arthritis of the ankle joint following a high-voltage electrical burn involving the lower extremity. We report a case of the pyogenic arthritis of the ankle joint following a high-voltage electrical burn involving the lower extremity.

  5. Analysis of predictor factors of limb amputation in patients with high-voltage electrical burns

    OpenAIRE

    2015-01-01

    Background: Limb amputation is considered one of the most devastating consequences of electrical injury. Any factors that correlate with the degree of muscle damage can be used to predict the necessity of limb amputation. The aim of this study was to determine the factors that can be used to predict limb amputation in high-voltage electrically injured patients. Methods: Eighty-two high-voltage electrically injured patients were admitted to the Department of Plastic and Reconstructive Surg...

  6. Review of Adult Electrical Burn Injury Outcomes Worldwide: An Analysis of Low-Voltage vs High-Voltage Electrical Injury.

    Science.gov (United States)

    Shih, Jessica G; Shahrokhi, Shahriar; Jeschke, Marc G

    The aims of this article are to review low-voltage vs high-voltage electrical burn complications in adults and to identify novel areas that are not recognized to improve outcomes. An extensive literature search on electrical burn injuries was performed using OVID MEDLINE, PubMed, and EMBASE databases from 1946 to 2015. Studies relating to outcomes of electrical injury in the adult population (≥18 years of age) were included in the study. Forty-one single-institution publications with a total of 5485 electrical injury patients were identified and included in the present study. Fourty-four percent of these patients were low-voltage injuries (LVIs), 38.3% high-voltage injuries (HVIs), and 43.7% with voltage not otherwise specified. Forty-four percentage of studies did not characterize outcomes according to LHIs vs HVIs. Reported outcomes include surgical, medical, posttraumatic, and others (long-term/psychological/rehabilitative), all of which report greater incidence rates in HVI than in LVI. Only two studies report on psychological outcomes such as posttraumatic stress disorder. Mortality rates from electrical injuries are 2.6% in LVI, 5.2% in HVI, and 3.7% in not otherwise specified. Coroner's reports revealed a ratio of 2.4:1 for deaths caused by LVI compared with HVI. HVIs lead to greater morbidity and mortality than LVIs. However, the results of the coroner's reports suggest that immediate mortality from LVI may be underestimated. Furthermore, on the basis of this analysis, we conclude that the majority of studies report electrical injury outcomes; however, the majority of them do not analyze complications by low vs high voltage and often lack long-term psychological and rehabilitation outcomes after electrical injury indicating that a variety of central aspects are not being evaluated or assessed.

  7. MR imaging findings of high-voltage electrical burns in the upper extremities: correlation with angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gyung Kyu; Kang, Ik Won; Hwang, Dae Hyun; Min, Seon Jung; Han, You Mi (Dept. of Radiology, Hallym Univ. College of Medicine, Hangang Sacred Heart Hospital, Seoul (Korea, Republic of)); Suh, Kyung Jin (Dept. of Radiology, Dongguk Univ. College of Medicine, Gyeongju Hospital, Gyeongju (Korea, Republic of)), email: kyungjin.suh@gmail.com; Choi, Min Ho (Dept. of Internal Medicine, Hallym Univ. College of Medicine, Hangang Sacred Heart Hospital, Seoul (Korea, Republic of))

    2011-02-15

    Background: A high-voltage electrical burn is often associated with deep muscle injuries. Hidden, undetected deep muscle injuries have a tendency for progressive tissue necrosis, and this can lead to major amputations or sepsis. MRI has excellent soft tissue contrast and it may aid in differentiating the areas of viable deep muscle from the areas of non-viable deep muscle. Purpose: To describe the MR imaging findings of a high-voltage electrical burn in the upper extremity with emphasis on the usefulness of the gadolinium-enhanced MRI and to compare the MR imaging findings with angiography. Material and Methods: We retrospectively reviewed the imaging studies of six patients with high-voltage electrical burns who underwent both MRI and angiography at the burn center of our hospital from January 2005 to December 2009. The imaging features were evaluated for the involved locations, the MR signal intensity of the affected muscles, the MR enhancement pattern, the involved arteries and the angiographic findings (classified as normal, sluggish flow, stenosis or occlusion) of the angiography of the upper extremity. We assessed the relationship between the MR imaging findings and the angiographic findings. Results: The signal intensities of affected muscles were isointense or of slightly high signal intensity as compared with the adjacent unaffected skeletal muscle on the T1-weighted MR images. Affected muscles showed heterogenous high signal intensity relative to the adjacent unaffected skeletal muscle on the T2- weighted images. The gadolinium-enhanced T1-weighted images showed diffuse inhomogeneous enhancement or peripheral rim enhancement of the affected muscles. The angiographic findings of the arterial injuries showed complete occlusion in three patients, severe stenosis in two patients and sluggish flow in one patient. Of these, the five patients with complete occlusion or severe stenosis on angiography showed non-perfused and non-viable areas of edematous muscle on

  8. MRI findings of the brain in high-voltage electrical burn patient: case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Cheung Sook; Hong, Sung Hwan; Lee, Myung Joon; Cho, Seong Whi; Lee, Eil Seong; Kang, Ik Won [Hallym University College of Medicine, Seoul (Korea, Republic of)

    2003-05-01

    We report the delayed sequelae arising in a case of electrical injury, reviewing the literature on the subject and focusing on the MRI findings of the brain. A 23-year-old male suffered burns to the left parietal scalp, both feet, and the anterior chest wall. Neurological symptoms and MRI abnormalities appeared 14 days after the insult and continued for about three months. T1-weight MR images demonstrated homogeneous hypointensity, while T2-weighted images depicted hyperintense finger-like projections. Contrast-enhanced T1-weighted images demonstrated strong band-like enhancement, indicating meningeal hyperemia. Follow-up MR imaging showed that the lesion had disappeared, indicating that the cerebral edema and meaningeal hyperemia were reversible.

  9. Bilateral Lower Limb Amputations in a Nigerian Child Following High-Voltage Electrical Burns Injury: A Case Report

    OpenAIRE

    Dim, EM; Amanari, OC; Nottidge, TE; Inyang, UC; Nwashindi, A

    2013-01-01

    Abstract The human body conducts electricity very well. Direct contact with electric current can be lethal. The passage of electric current through the body is capable of producing a wide spectrum of injuries, including serious damage to the heart, brain, skin and muscles. Naked high-voltage electric cables negligently abandoned in residential, commercial and industrial areas are a recipe for disaster. This is a case report of a 5-year girl child who had bilateral lower limb gangrene followin...

  10. High voltage electricity installations a planning perspective

    CERN Document Server

    Jay, Stephen Andrew

    2006-01-01

    The presence of high voltage power lines has provoked widespread concern for many years. High Voltage Electricity Installations presents an in-depth study of policy surrounding the planning of high voltage installations, discussing the manner in which they are percieved by the public, and the associated environmental issues. An analysis of these concerns, along with the geographical, environmental and political influences that shape their expression, is presented. Investigates local planning policy in an area of the energy sector that is of highly topical environmental and public concern Cover

  11. High voltage and electrical insulation engineering

    CERN Document Server

    Arora, Ravindra

    2011-01-01

    "The book is written for students as well as for teachers and researchers in the field of High Voltage and Insulation Engineering. It is based on the advance level courses conducted at TU Dresden, Germany and Indian Institute of Technology Kanpur, India. The book has a novel approach describing the fundamental concept of field dependent behavior of dielectrics subjected to high voltage. There is no other book in the field of high voltage engineering following this new approach in describing the behavior of dielectrics. The contents begin with the description of fundamental terminology in the subject of high voltage engineering. It is followed by the classification of electric fields and the techniques of field estimation. Performance of gaseous, liquid and solid dielectrics under different field conditions is described in the subsequent chapters. Separate chapters on vacuum as insulation and the lightning phenomenon are included"--

  12. Early treatment of high-voltage electric burn wound in the limbs%四肢高压电烧伤创面的早期处理

    Institute of Scientific and Technical Information of China (English)

    沈余明; 胡骁骅; 宓惠茹; 于东宁; 覃风均; 陈辉; 王浩; 张国安

    2011-01-01

    Objective To summarize the experience of early treatment of high-voltage electric burn wounds in the limbs. Methods Fifty-four patients (50 males and 4 females,aged from 10 to 56 years) with high-voltage electric burn wounds in 97 limbs (67 upper limbs and 30 lower limbs) were hospitalized in our burn wards from January 2003 to December 2010. A total of 119 burn wounds in wrist-forearm,forearm-elbow-upper arm,shoulder-axillary region,ankle-foot,lower leg,around the knee,thigh-inguinal region were treated with incision for decompression within 10 days after burn. Under the premise of relatively stable systemic condition of the patients,certain surgical operations were performed as follows. (1) Sixteen limbs with 16 wounds were amputated,among them forearm amputation was performed for 5 upper limbs with necrosis,with preservation of elbow joints,and the residual wounds of the elbow and upper arm were repaired with pedicled latissimus dorsi musculo-cutaneous flaps;1 upper limb with upper arm amputated,with preservation of shoulder joint,was repaired with pedicled latissimus dorsi musculo-cutaneous flap. (2) Ninety-five wounds were covered with various tissue flaps with abundant blood supply after early debridement,in which 3 brachial arteries,1 vein,1 brachial artery and vein were reconstructed in 5 wrist wounds,artery reconstruction was performed in elbow wound of 1 case with injured brachial artery. (3) Eight wounds were treated with free skin grafting. Wound healing conditions were observed and followed up. Results Wounds in 16 limbs healed after amputation and repair. Blood supply and (or) venous return of hands were restored in 5 wrist wounds after vessel reconstruction. After artery reconstruction,abundant blood supply was observed in 1 case with injured brachial artery and amputation was avoided. Necrosis occurred in distal parts of tissue flaps in 5 wounds after grafting,in which 2 wounds healed after removal of necrotic tissue followed by closure with suture

  13. HIGH VOLTAGE SAFETY MANAGEMENT SYSTEM OF ELECTRIC VEHICLE

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    In order to improve the drivability and energy efficiency of electric vehicle (EV), more and more batteries are connected in series with high voltage which makes it necessary to monitor the electric parameters of high voltage system (HVS) to ensure the high voltage safety. A high voltage safety management system is developed to solve this critical issue. Several key electric parameters including pre-charge, contact resistance, insulation resistance and remaining capacity are monitored and analyzed based on the presented equivalent models. An electronic unit called high voltage safety controller is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated and the on-line electric parameters monitor strategy is discussed. The real vehicle experiment results indicate that the high voltage safety management system designed is suitable for EV application.

  14. Electrical system architecture having high voltage bus

    Science.gov (United States)

    Hoff, Brian Douglas [East Peoria, IL; Akasam, Sivaprasad [Peoria, IL

    2011-03-22

    An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

  15. [Fatal electric arc accidents due to high voltage].

    Science.gov (United States)

    Strauch, Hansjürg; Wirth, Ingo

    2004-01-01

    The frequency of electric arc accidents has been successfully reduced owing to preventive measures taken by the professional association. However, the risk of accidents has continued to exist in private setting. Three fatal electric arc accidents caused by high voltage are reported with reference to the autopsy findings.

  16. Electric Insulation Detection Method for High-voltage Insulators

    Directory of Open Access Journals (Sweden)

    Wang Jiajun

    2013-07-01

    Full Text Available The principle of partial discharge detection is that through partial bridged discharge under high voltage electric field, it detects the inner air-filled cavity of high-voltage insulators. And it is a nondestructive detection method based on discharge magnitude to judge the insulation quality. The detecting system that adopts the partial discharge detection is more rigorous than testing system for electricity products, which must have small discharge capacity and higher sensitivity. This paper describes the principles of partial discharge detection and analysis insulation detection.

  17. [Transient high frequency nodal rhythm after a high voltage electric shock. Report of one case].

    Science.gov (United States)

    Supervía, August; Del Baño, Francisco; Aguirre, Alfons; Membrilla, Estela

    2013-09-01

    Electrical shock can cause a direct myocardial damage and different types of arrhythmias, which are uncommon and occur more often when there is a high voltage exposure. We report a 19-year-old male that received a high voltage shock, falling thereafter from an altitude of four meters. On admission to the emergency room, he had second and third degree burns in the right hand and the left thigh. The electrocardiogram showed a nodal rhythm of 72 beats per minute. After four hours of monitoring, sinus rhythm returned spontaneously.

  18. Influence of high-voltage electric burn on the microcirculation of heart in rabbit%高压电烧伤对兔心脏微循环的影响

    Institute of Scientific and Technical Information of China (English)

    张庆富; 周慧敏; 王车江; 邵洪波

    2012-01-01

    Objective To study the influence of high-voltage electric burn on the microcirculation of heart in rabbit. Methods One-hundred and twenty New Zealand rabbits of clean grade were divided into control group (C) and electric burn group (EB) according to the random number table,with 60 rabbits in each group.Rabbits in EB group were subjected to high-vohage electric burn ( the electrical current flow into the left foreleg at the lateral side of proximal end and out from the corresponding site of the right hind leg) with voltage regulator and experimental transformer.Rabbits in C group were sham injured with the same devices without electrification.At 15 minutes before injury,and 5 minutes,1,2,4,8 hour (s) post injury ( PIM or PIH ),ten rabbits in each group were chosen to examine the cardiac apex microcirculation hemoperfusion (CAMH) with laser Doppler hemoperfusion image instrument.The morphologic changes of microvessels of left ventricular wall tissues of 2 rabbits from each of the 10 rabbits collected at above-mentioned time points were observed with light microscope and transmission electron microscope.Auricular vein blood of rabbit was harvested at above-mentioned time points for the determination of aspartate amino transferase ( AST),lactate dehydrogenase ( LDH ),hydroxybutyrate dehydrogenase ( HBDH ),creatine kinase ( CK),and creatine kinase isozyme MB (CK-MB) by full-automatic biochemical analyzer.Data were processed with two-factor analysis of variance and LSD test. Results ( 1 ) The differences between C group and EB group in detection results were statistically significant,with F values from 425.991 to 3046.834,P values all below 0.01.Only the data within EB group were comparable.(2) At PIM 5,the CAMH value of rabbits in EB group was (1.96 ±0.09) V,which was lower than that at 15 minutes before injury [(4.34±0.35) V,P < 0.01 ].The CAMH value of rabbits in EB group was increased at PIH 1 [ (3.43 ± 0.30) V ],and then it showed a tendency of decrease.(3

  19. Static Electricity as Part of Electromagnetic Environment on High-Voltage Electrical Substation

    Directory of Open Access Journals (Sweden)

    M. Fursanov

    2012-01-01

    Full Text Available Causes of occurrences electrostatic discharges (ESD on high-voltage electric substation were investigated and dependences values ESD’s on parameters interaction structures, humidity of air were found. Experimental research values ESD’s on high-voltage electric substation and in man-made conditions was fulfilled. Uncertainty measurement’s was taken into consideration by research results analyze. Matching with research of other authors was made. Danger ESD’s for electric devises was established.

  20. Pattern of high voltage electrical injuries in the Kashmir valley: a 10-year single centre experience.

    Science.gov (United States)

    Kasana, R A; Baba, P U F; Wani, A H

    2016-12-31

    The objective was to study the clinical profile of high voltage electrical injuries in Kashmir, and various prevention and safety measures to bring down the incidence of such injuries in the future. All patients (176) with high voltage electrical injuries reporting to our centre from January 2001 to December 2010 were included in the study. The most common age group was 20-40 years, with mean age of 29.77 ± 8.98 years. Incidence was higher among the rural population (68.75%) than in urban areas (31.25%), and in the winter months. Electricians comprised 47.16% of victims. The most common mode of injury was touching a live wire directly or indirectly, and was seen in 63.64% of victims. Average total body surface burned was 15.27 ± 10.15 percent. Right upper limb was most commonly involved (64.20% of patients). Compartment syndrome was seen in 40.34% of patients, and fasciotomies on all the affected limbs saved around half of them. An average of 3.91 surgical procedures per patient were performed. Around one-third of the victims required major amputations. Reconstructive procedures were required in 49.43% of patients. Average hospital stay was 26.81 days. Average mortality rate was 2.27%. High voltage electrical injuries are not uncommon in the Kashmir Valley, and electrical workers are at higher risk. The incidence of high voltage injuries would not be so high if the workers were properly trained, hazards of high-tension lines were explained and the use of safety equipment was made mandatory.

  1. MATHEMATICAL MODEL OF HYBRID ELECTRIC VEHICLE HIGH-VOLTAGE BATTERY IDENTIFICATION

    Directory of Open Access Journals (Sweden)

    S. Serikov

    2010-01-01

    Full Text Available The mathematical model of hybrid electric vehicle NiMH high-voltage battery is obtained. This model allows to explore the interaction of vehicle tractive electric drive and high-voltage battery at the electric motive power motion and in the process of recuperation of braking kinetic energy.

  2. Review of the Dynamics of Coalescence and Demulsification by High-Voltage Pulsed Electric Fields

    OpenAIRE

    Ye Peng; Tao Liu; Haifeng Gong; Xianming Zhang

    2016-01-01

    The coalescence of droplets in oil can be implemented rapidly by high-voltage pulse electric field, which is an effective demulsification dehydration technological method. At present, it is widely believed that the main reason of pulse electric field promoting droplets coalescence is the dipole coalescence and oscillation coalescence in pulse electric field, and the optimal coalescence pulse electric field parameters exist. Around the above content, the dynamics of high-voltage pulse electric...

  3. Evaluation of the effectiveness of neurofeedback in the reduction of Posttraumatic stress disorder (PTSD) in a patient following high-voltage electric shock with the use of ERPs

    OpenAIRE

    Anna Chrapusta; Maria Pąchalska; Magdalena Wilk-Frańczuk; Małgorzata Starczyńska; Juri D. Kropotov

    2015-01-01

    Background. The aim of our research was an evaluation of the effectiveness of neurofeedback in reducing the symptoms of Post-trauma stress disorder (PTSD), which had developed as a result of a high-voltage electric burn to the head. Quantitative EEG (QEEG) and Event related potentials (ERPs) were utilised in the evaluation. Case study. A 21-year-old patient, experienced 4[sup]th[/sup] degree burns to his head as a result of a high-voltage electric burn. The patient was repeatedly opera...

  4. A Novel Series Connected Batteries State of High Voltage Safety Monitor System for Electric Vehicle Application

    Directory of Open Access Journals (Sweden)

    Qiang Jiaxi

    2013-01-01

    Full Text Available Batteries, as the main or assistant power source of EV (Electric Vehicle, are usually connected in series with high voltage to improve the drivability and energy efficiency. Today, more and more batteries are connected in series with high voltage, if there is any fault in high voltage system (HVS, the consequence is serious and dangerous. Therefore, it is necessary to monitor the electric parameters of HVS to ensure the high voltage safety and protect personal safety. In this study, a high voltage safety monitor system is developed to solve this critical issue. Four key electric parameters including precharge, contact resistance, insulation resistance, and remaining capacity are monitored and analyzed based on the equivalent models presented in this study. The high voltage safety controller which integrates the equivalent models and control strategy is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated, and the online electric parameters monitor strategy is analyzed and discussed. The test results indicate that the high voltage safety monitor system designed in this paper is suitable for EV application.

  5. Review of the Dynamics of Coalescence and Demulsification by High-Voltage Pulsed Electric Fields

    Directory of Open Access Journals (Sweden)

    Ye Peng

    2016-01-01

    Full Text Available The coalescence of droplets in oil can be implemented rapidly by high-voltage pulse electric field, which is an effective demulsification dehydration technological method. At present, it is widely believed that the main reason of pulse electric field promoting droplets coalescence is the dipole coalescence and oscillation coalescence in pulse electric field, and the optimal coalescence pulse electric field parameters exist. Around the above content, the dynamics of high-voltage pulse electric field promoting the coalescence of emulsified droplets is studied by researchers domestically and abroad. By review, the progress of high-voltage pulse electric field demulsification technology can get a better understanding, which has an effect of throwing a sprat to catch a whale on promoting the industrial application.

  6. Pulsed high voltage electric discharge disinfection of microbially contaminated liquids.

    Science.gov (United States)

    Anpilov, A M; Barkhudarov, E M; Christofi, N; Kop'ev, V A; Kossyi, I A; Taktakishvili, M I; Zadiraka, Y

    2002-01-01

    To examine the use of a novel multielectrode slipping surface discharge (SSD) treatment system, capable of pulsed plasma discharge directly in water, in killing micro-organisms. Potable water containing Escherichia coli and somatic coliphages was treated with pulsed electric discharges generated by the SSD. The SSD system was highly efficient in the microbial disinfection of water with a low energy utilization (eta approximately 10-4 kW h l-1). The SSD treatment was effective in the destruction of E. coli and its coliphages through the generation of u.v. radiation, ozone and free radicals. The non-thermal treatment method can be used for the eradication of micro-organisms in a range of contaminated liquids, including milk, negating the use of pasteurization. The method utilizes multipoint electric discharges capable of treating large volumes of liquid under static and flowing regimes.

  7. [Accident risk perception in high-voltage electrical maintenance workers].

    Science.gov (United States)

    Micheli, M; Zanaletti, W; Giorgi, I; Argentero, P; Candura, S M

    2006-01-01

    Promoting safety at work represents a fundamental task for achieving improvement in the quality of working life and preventing accidental injuries at work. Nevertheless, over the last few decades injuries at work have continued to constitute a significant problem. The aim of this study was to examine accident risk perception in a sample of 45 subjects employed in the electricity sector and to relate their risk perception to personality characteristics, cognitive functioning, and personal and professional history. The instruments used were: "Cognitive Behavioral Assessment 2.0", the "Workplace safety questionnaire" (an Italian questionnaire on safety at work), and a battery of neuropsychological tests. Findings show that electricity (current variability) was perceived as the most serious risk factor, while the most frequent perceived risk factors for accidents were accidental falls, cuts and bruises. The subjects of our sample showed a good awareness of risk perception, and good mood response and augmented psychophysiological activation during accidental injuries.

  8. Study of seismic response and vibration control of High voltage electrical equipment damper based on TMD

    Science.gov (United States)

    Liu, Chuncheng; Wang, Chongyang; Mao, Long; Zha, Chuanming

    2016-11-01

    Substation high voltage electrical equipment such as mutual inductor, circuit interrupter, disconnecting switch, etc., has played a key role in maintaining the normal operation of the power system. When the earthquake disaster, the electrical equipment of the porcelain in the transformer substation is the most easily to damage, causing great economic losses. In this paper, using the method of numerical analysis, the establishment of a typical high voltage electrical equipment of three dimensional finite element model, to study the seismic response of a typical SF6 circuit breaker, at the same time, analysis and contrast the installation ring tuned mass damper (TMD damper for short), by changing the damper damping coefficient and the mass block, install annular TMD vibration control effect is studied. The results of the study for guiding the seismic design of high voltage electrical equipment to provide valuable reference.

  9. Self-Healable Electrical Insulation for High Voltage Applications

    Science.gov (United States)

    Williams, Tiffany S.

    2017-01-01

    Polymeric aircraft electrical insulation normally degrades by partial discharge with increasing voltage, which causes excessive localized Joule heating in the material and ultimately leads to dielectric failure of the insulator through thermal breakdown. Developing self-healing insulation could be a viable option to mitigate permanent mechanical degradation, thus increasing the longevity of the insulation. Instead of relying on catalyst and monomer-filled microcapsules to crack, flow, and cure at the damaged sites described in well-published mechanisms, establishment of ionic crosslinks could allow for multiple healing events to occur with the added benefit of achieving full recovery strength under certain thermal environments. This could be possible if the operating temperature of the insulator is the same as or close to the temperature where ionic crosslinks are formed. Surlyn, a commercial material with ionic crosslinks, was investigated as a candidate self-healing insulator based off prior demonstrations of self-healing behavior. Thin films of varying thicknesses were investigated and the effects of thickness on the dielectric strength were evaluated and compared to representative polymer insulators. The effects of thermal conditioning on the recovery strength and healing were observed as a function of time following dielectric breakdown. Moisture absorption was also studied to determine if moisture absorption rates in Surlyn were lower than that of common polyimides.

  10. The Thawing Characteristic of Frozen Tofu under High-Voltage Alternating Electric Field

    Directory of Open Access Journals (Sweden)

    Shilong Deng

    2017-01-01

    Full Text Available To systematically and comprehensively investigate the high voltage alternating electric field (HVAEF thawing processing, we investigated the high-voltage electric field thawing characteristic of the frozen tofu at different voltages for alternating current (AC. The thawing time, thawing loss of frozen tofu, and specific energy consumption (SEC of HVEF system were measured. Seven different mathematical models were then compared to simulate thawing time curves based on root mean square error, reduced mean square of deviation, and modeling efficiency. The results showed that the thawing rate of frozen tofu was notably greater in the high-voltage electric field system when compared to control. Both Linear and Quadratic models were the best mathematical models. Therefore, this work presents a facile and effective strategy for experimentally and theoretically determining the HVAEF thawing properties of frozen tofu.

  11. Effects of High-voltage Pulse Electric Field Treatment on the Structure Stability of Konjac Glucomannan

    Institute of Scientific and Technical Information of China (English)

    YAO Min-Na; FAN Lin-Lin; LIU Ya-Nan; CHEN Qing-Ai; ZENG Yuan; JIAN Wen-Jie; PANG Jie

    2011-01-01

    Structures of KGM treated in two high-voltage pulse electric fields were characterized by infrared spectroscopy,Raman spectroscopy,X-ray diffraction and so on.The results showed that intermolecular hydrogen bonding interactions of KGM were reduced after being treated with high-voltage pulse electric field,but there was no significant effect on its fiber chain form and thermal characteristics.Results of the study can provide a useful reference for further study on the structure and property of KGM,and especially can provide theoretical basis for the effect of physical field on the foodstuff deep processing related to KGM.

  12. Insulation co-ordination in high-voltage electric power systems

    CERN Document Server

    Diesendorf, W

    2015-01-01

    Insulation Co-ordination in High-Voltage Electric Power Systems deals with the methods of insulation needed in different circumstances. The book covers topics such as overvoltages and lightning surges; disruptive discharge and withstand voltages; self-restoring and non-self-restoring insulation; lightning overvoltages on transmission lines; and the attenuation and distortion of lightning surges. Also covered in the book are topics such as the switching surge designs of transmission lines, as well as the insulation coordination of high-voltage stations. The text is recommended for electrical en

  13. High voltage bus and auxiliary heater control system for an electric or hybrid vehicle

    Science.gov (United States)

    Murty, Balarama Vempaty

    2000-01-01

    A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

  14. The effects of high-voltage pulse electric discharges on ion adsorption on activated carbons

    Science.gov (United States)

    Gafurov, M. M.; Sveshnikova, D. A.; Larin, S. V.; Rabadanov, K. Sh.; Shabanova, Z. E.; Yusupova, A. A.; Ramazanov, A. Sh.

    2008-07-01

    The effects of high-voltage pulse electric discharges (HPED) on sorption of boron and sulfate ions on activated carbons of different kinds (KM-2, BAU, DAK) were investigated. The effect of HPED activation on the sorption characteristics of the systems was found to be similar to the temperature effect.

  15. Study of Energy Losses in High-Voltage Induction Motor Electric Drive

    Directory of Open Access Journals (Sweden)

    Svilen Rachev

    2016-10-01

    Full Text Available The dynamic behavior during operation of the high-voltage induction motor electric drive has been studied by means of mathematical model developed. The purpose is to draw out more clearly picture of operation of high-voltage induction motor drives. The system of differential equations has been transformed and solved using suitable software. As a result the values of the energy losses components in the induction motor have been obtained according to different values of supply voltage and factor of inertia. Some of the study results have been presented graphically. An analysis has been made and conclusions from the results obtained have been done.

  16. An Analysis of Magnetic Field Environment Near High-Voltage Power Lines and Contact Wires of Electric Railways

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Image method is used in this paper to calculate the value of magnetic field near high-voltage transmission lines and electric railways. Areas in which the magnetic field is less than 0.002 Gauss are given and the magnetic pollution of high-voltage power transmission lines and electric railways is discussed

  17. Analysis of electric field control methods for foil coils in high-voltage linear actuators

    Directory of Open Access Journals (Sweden)

    Beek T.A. van

    2015-12-01

    Full Text Available This paper describes multiple electric field control methods for foil coils in high-voltage coreless linear actuators and their sensitivity to misalignment. The investigated field control methods consist of resistive, refractive, capacitive and geometrical solutions for mitigating electric stress at edges and corners of foil coils. These field control methods are evaluated using 2-D boundary element and finite element methods. A comparison is presented between the field control methods and their ability to mitigate electric stress in coreless linear actuators. Furthermore, the sensitivity to misalignment of the field control methods is investigated.

  18. CT findings of the brain damages resulting from the high voltage electric injuries

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Eun; Kim, Young Keun; Shim, Hyang Yi; Lee, Shin Hyung; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    1994-02-15

    The purpose of this study is to evaluate the CT features and pathogenesis of the electric brain injuries. We reviewed the CT scans of 3 patients injured by high-voltage electricity. We evaluated the findings early and delayed periods in each patients. The early CT findings were diffuse brain edema, scalp swelling, and focal hemorrhagic contusion. The findings of delayed period were cerebral infarction, pneumocephalus, brain abscess, and pneumatocele. CT was useful to correlate the pathogenesis and variable features of electric brain injuries.

  19. Removal of phenol by activated alumina bed in pulsed high-voltage electric field

    Institute of Scientific and Technical Information of China (English)

    ZHU Li-nan; MA Jun; YANG Shi-dong

    2007-01-01

    A new process for removing the pollutants in aqueous solution-activated alumina bed in pulsed high-voltage electric field was investigated for the removal of phenol under different conditions. The experimental results indicated the increase in removal rate with increasing applied voltage, increasing pH value of the solution, aeration, and adding Fe2+. The removal rate of phenol could reach 72.1 % when air aeration flow rate was 1200 ml/min, and 88.2 % when 0.05 mmol/L Fe2+ was added into the solution under the conditions of applied voltage 25 kV, initial phenol concentration of 5 mg/L, and initial pH value 5.5. The addition of sodium carbonate reduced the phenol removal rate. In the pulsed high-voltage electric field, local discharge occurred at the surface of activated alumina, which promoted phenol degradation in the thin water film. At the same time, the space-time distribution of gas-liquid phases was more uniform and the contact areas of the activated species generated from the discharge and the pollutant molecules were much wider due to the effect of the activated alumina bed. The synthetical effects of the pulsed high-voltage electric field and the activated alumina particles accelerated phenol degradation.

  20. Electric eels use high-voltage to track fast-moving prey.

    Science.gov (United States)

    Catania, Kenneth C

    2015-10-20

    Electric eels (Electrophorus electricus) are legendary for their ability to incapacitate fish, humans, and horses with hundreds of volts of electricity. The function of this output as a weapon has been obvious for centuries but its potential role for electroreception has been overlooked. Here it is shown that electric eels use high-voltage simultaneously as a weapon and for precise and rapid electrolocation of fast-moving prey and conductors. Their speed, accuracy, and high-frequency pulse rate are reminiscent of bats using a 'terminal feeding buzz' to track insects. Eel's exhibit 'sensory conflict' when mechanosensory and electrosensory cues are separated, striking first toward mechanosensory cues and later toward conductors. Strikes initiated in the absence of conductors are aborted. In addition to providing new insights into the evolution of strongly electric fish and showing electric eels to be far more sophisticated than previously described, these findings reveal a trait with markedly dichotomous functions.

  1. Electrical burns: Highlights from a 5-year retrospective analysis.

    Science.gov (United States)

    Kurt, Alper; Yıldırım, Kamil; Yağmur, Çağlayan; Kelahmetoğlu, Osman; Aslan, Ozan; Gümüş, Murat; Güneren, Ethem

    2016-05-01

    Electrical burns are the third most common cause of burn injuries, after scald and flame burns. In spite of decreasing mortality rates as advancements are made in treatment modalities and medical equipment, significant complications and socioeconomic consequences still accompany electrical burns. Analyzed in the present study were data from patients hospitalized for electrical burns between 2008 and 2012 in the Samsun Training and Research Hospital, the only burn care center in the Black Sea region of Turkey. Data from 94 patients (84 males, 10 females) hospitalized for electrical burns between 2008 and 2012 were retrospectively evaluated. Patient age, gender, occupation, presence of coexisting trauma, burn degree, burned percentage of total body surface area (TBSA), voltage of the electric current (low or high), medical cost (per day and total), and infection rates were analyzed. Mean patient age was 26.4±13.2 years. Ten patients were female (10.6%) and 84 were male (89.4%). High-voltage burns were sustained by 47 patients (50%) and low-voltage burns by 42 (44.7%); the remaining 5 were flash burns. Mean burned TBSA was 21.8±19.8% in high-voltage injuries and 11.9±6.9% in low-voltage injuries. Seven patients had accompanying soft tissue lacerations, major bone fractures, or epidural hematomas. Findings of infection were encountered in 31 patients (32.9%), and appropriate treatments were initiated according to culture results. Mean duration of hospitalization was 21.3±19.8 days in patients with high-voltage burns and 8.6±6.2 days in patients with low-voltage burns. Mean hospital stay was 2.5-fold longer, and total medical costs were 4-fold higher in patients with high-voltage burns. Young adult males who were injured in industrial accidents constituted the majority of high-voltage burn patients. Incidence of these injuries may be reduced by improvements in training regarding the safe use of electrical devices, and correct installation and safe maintenance of

  2. CLINICAL STUDY OF ELECTRICAL BURNS AMONG ALL BURNS CASES- 3 YEARS’ EXPERIENCE

    Directory of Open Access Journals (Sweden)

    Nagabathula Durga Prasad

    2017-08-01

    Full Text Available BACKGROUND With the advances in technology, electrical injuries are becoming more common and are the leading cause of work-related traumatic death. One third of all electrical traumas and most high-voltage injuries are job related and more than 50% of these injuries result from power line contact. The management of the major burn injury represents a significant challenge to every member of the burns team. Most of electrical burns present with gangrene of toes and limbs with eschar over body parts. Their presentation is mostly due to contact with high-voltage electricity at their work places. MATERIALS AND METHODS A retrospective study was made to study the clinico-social profile of patients suffering electric burns admitted into Department of General Surgery. RESULTS 92 cases were evaluated and studied. Majority of patients developed gangrene of limbs and toes. Amputations and skin grafting was done. Most patients who suffered electric burns were males of age group 21 to 40 years. All cases are accidental and mostly occurred at work places. Most electric burns are high-voltage based and caused deep burns. Major complications like acute renal failure and septicaemia were encountered. Most of them suffered 16 to 30% burns. Most commonly isolated organism from wounds is pseudomonas. Most of them suffered a hospital stay of 1 to 2 months. CONCLUSION Electric burns are a burden to the society. Prevention is the best way to deal with them. Electricity-based employees have to be trained properly regarding safety measures to be taken. General education of public regarding safety measures can prevent electrical burn injuries.

  3. Study on Miniaturized UHF Antennas for Partial Discharge Detection in High-Voltage Electrical Equipment.

    Science.gov (United States)

    Liu, Jingcun; Zhang, Guogang; Dong, Jinlong; Wang, Jianhua

    2015-11-20

    Detecting partial discharge (PD) is an effective way to evaluate the condition of high-voltage electrical equipment insulation. The UHF detection method has attracted attention due to its high sensitivity, strong interference resistance, and ability to locate PDs. In this paper, a miniaturized equiangular spiral antenna (ESA) for UHF detection that uses a printed circuit board is proposed. I-shaped, L-shaped, and C-shaped microstrip baluns were designed to match the impedance between the ESA and coaxial cable and were verified by a vector network analyzer. For comparison, three other types of UHF antenna were also designed: A microstrip patch antenna, a microstrip slot antenna, and a printed dipole antenna. Their antenna factors were calibrated in a uniform electric field of different frequencies modulated in a gigahertz transverse electromagnetic cell. We performed comparison experiments on PD signal detection using an artificial defect model based on the international IEC 60270 standard. We also conducted time-delay test experiments on the ESA sensor to locate a PD source. It was found that the proposed ESA sensor meets PD signal detection requirements. The sensor's compact size makes it suitable for internal installation in high-voltage electrical equipment.

  4. Study on Miniaturized UHF Antennas for Partial Discharge Detection in High-Voltage Electrical Equipment

    Directory of Open Access Journals (Sweden)

    Jingcun Liu

    2015-11-01

    Full Text Available Detecting partial discharge (PD is an effective way to evaluate the condition of high-voltage electrical equipment insulation. The UHF detection method has attracted attention due to its high sensitivity, strong interference resistance, and ability to locate PDs. In this paper, a miniaturized equiangular spiral antenna (ESA for UHF detection that uses a printed circuit board is proposed. I-shaped, L-shaped, and C-shaped microstrip baluns were designed to match the impedance between the ESA and coaxial cable and were verified by a vector network analyzer. For comparison, three other types of UHF antenna were also designed: A microstrip patch antenna, a microstrip slot antenna, and a printed dipole antenna. Their antenna factors were calibrated in a uniform electric field of different frequencies modulated in a gigahertz transverse electromagnetic cell. We performed comparison experiments on PD signal detection using an artificial defect model based on the international IEC 60270 standard. We also conducted time-delay test experiments on the ESA sensor to locate a PD source. It was found that the proposed ESA sensor meets PD signal detection requirements. The sensor’s compact size makes it suitable for internal installation in high-voltage electrical equipment.

  5. Electrical conduction mechanism in bulk ceramic insulators at high voltages until dielectric breakdown

    Science.gov (United States)

    Neusel, C.; Jelitto, H.; Schneider, G. A.

    2015-04-01

    In order to develop and verify a dielectric breakdown model for bulk insulators thicker than 100 μm, the knowledge of the dominating conduction mechanism at high electric fields, or respectively voltages, is necessary. The dielectric breakdown is the electrical failure of an insulator. In some existing breakdown models, ohmic conduction is assumed as dominating conduction mechanism. For verification, the dominating dc conduction mechanism of bulk insulators at room temperature was investigated by applying high voltages up to 70 kV to the insulator until dielectric breakdown occurs. Four conduction models, namely, ohmic, space charge limited, Schottky, and Poole-Frenkel conduction, were employed to identify the dominating conduction mechanism. Comparing the calculated permittivities from the Schottky and Poole-Frenkel coefficients with experimentally measured permittivity, Schottky and Poole-Frenkel conduction can be excluded as dominating conduction mechanism. Based on the current density voltage characteristics (J-V-curve) and the thickness-dependence of the current density, space charge limited conduction (SCLC) was identified to be the dominating conduction mechanism at high voltages leading to dielectric breakdown. As a consequence, breakdown models based on ohmic conduction are not appropriate to explain the breakdown of the investigated bulk insulators. Furthermore, the electrical failure of the examined bulk insulators can only be described correctly by a breakdown model which includes SCLC as conduction mechanism.

  6. Numerical simulation of high voltage electric pulse comminution of phosphate ore

    Institute of Scientific and Technical Information of China (English)

    Razavian Seyed Mohammad; Rezai Bahram; Irannajad Mehdi; Ravanji Mohammad Hasan

    2015-01-01

    Numerical simulation of the electrical field distribution helps in-depth understanding of the mechanisms behind the responses and the benefits of the high voltage pulse comminution. The COMSOL Multiphysics package was used to numerically simulate the effect of ore compositions in this study. Regarding phos-phate ore particles shape and composition, the effects of mineral composition, particle size, particle shape and electrodes distance were investigated on the electrical field intensity and distribution. The results show that the induced electrical field is significantly dependent on the electrical properties of minerals, the feed particle size and the location of conductive minerals in ores. The angle of material contact sur-face with the discharge electrode is also an important factor in the intensity of electrical field. Moreover, it is found that the specific liberation effect at the disintegration of phosphate ore by electrical pulses is due to the locality of the electrical field at the interface of mineral components of the phosphate ore aggregates with different permittivities. However, the intensity of the electrical field increases with shar-pening the contact angle. Besides, the electrical discharge in the samples is converted to the elec-trohydraulic discharge across the surrounding water by changing the distance between the discharge electrode and sample surface.

  7. Increase in the scattering of electric field lines in a new high voltage SOI MESFET

    Science.gov (United States)

    Anvarifard, Mohammad K.

    2016-09-01

    This paper illustrates a new efficient technique to enhance the critical features of a silicon-on-insulator metal-semiconductor field-effect transistor (SOI MESFET) applied in high voltage applications. The structure we proposed utilizes a new method to scatter the electric field lines along the channel region. Realization of two trenches with different materials, which a trench is created in the channel region and the other one is created in the buried oxide, helps the proposed structure to improve the breakdown voltage, driving current, drain-source conductance, minimum noise figure, unilateral power gain and output power density. Exploring the obtained results, the proposed structure has superior electrical performance in comparison to the conventional structure.

  8. Technological Aspects: High Voltage

    CERN Document Server

    Faircloth, D C

    2013-01-01

    This paper covers the theory and technological aspects of high-voltage design for ion sources. Electric field strengths are critical to understanding high-voltage breakdown. The equations governing electric fields and the techniques to solve them are discussed. The fundamental physics of high-voltage breakdown and electrical discharges are outlined. Different types of electrical discharges are catalogued and their behaviour in environments ranging from air to vacuum are detailed. The importance of surfaces is discussed. The principles of designing electrodes and insulators are introduced. The use of high-voltage platforms and their relation to system design are discussed. The use of commercially available high-voltage technology such as connectors, feedthroughs and cables are considered. Different power supply technologies and their procurement are briefly outlined. High-voltage safety, electric shocks and system design rules are covered.

  9. Bilateral maculopathy following electrical burn: case report

    Directory of Open Access Journals (Sweden)

    Leandro Dario Faustino

    Full Text Available CONTEXT: Electrical burns are an important etiology in dealing with patients suffering from burns. In situations of extensive deep lesions of multiple organs and systems affecting young and economically active people, there is a need for expensive multidisciplinary treatment, with a high socioeconomic cost for the community. Among the permanent injuries that explain this high cost, eye injuries stand out, since they are widely disabling. Although rare, lesions of the posterior segment of the eye are associated with higher incidence of major sequelae, and thus deserve special attention for dissemination and discussion of the few cases observed.CASE REPORT: The authors report the case of a patient who suffered high-voltage electrical burns and presented bilateral maculopathy, which evolved with a need for a surgical approach to repair retinal detachment and permanent low visual acuity.CONCLUSION: This report highlights the rarity of the etiology of maculopathy and the need for campaigns for prevention not only of burns in general, but also especially of electrical burns.

  10. Potential therapeutic mechanism of extremely low-frequency high-voltage electric fields in cells.

    Science.gov (United States)

    Kim, Ka-Eun; Park, Soon-Kwon; Nam, Sang-Yun; Han, Tae-Jong; Cho, Il-Young

    2016-05-18

    The aim of this survey was to provide background theory based on previous research to elucidate the potential pathway by which medical devices using extremely low-frequency high-voltage electric fields (ELF-HVEF) exert therapeutic effects on the human body, and to increase understanding of the AC high-voltage electrotherapeutic apparatus for consumers and suppliers of the relevant devices. Our review revealed that an ELF field as weak as 1-10 μ V/m can induce diverse alterations of membrane proteins such as transporters and channel proteins, including changes in Ca + + binding to a specific site of the cell surface, changes in ion (e.g., Ca + + ) influx or efflux, and alterations in the ligand-receptor interaction. These alterations then induce cytoplasmic responses within cells (Ca + + , cAMP, kinases, etc.) that can have impacts on cell growth, differentiation, and other functional properties by promoting the synthesis of macromolecules. Moreover, increased cytoplasmic Ca + + involves calmodulin-dependent signaling and consequent Ca + + /calmodulin-dependent stimulation of nitric oxide synthesis. This event in turn induces the nitric oxide-cGMP-protein kinase G pathway, which may be an essential factor in the observed physiological and therapeutic responses.

  11. A Complex Permittivity Based Sensor for the Electrical Characterization of High-Voltage Transformer Oils

    Directory of Open Access Journals (Sweden)

    Panayota Vassiliou

    2005-05-01

    Full Text Available This work investigates the use of a specially designed cylindrical metal cell, inorder to obtain complex permittivity and tanδ data of highly insulating High Voltage (HVtransformer oil samples. The data are obtained at a wide range of frequencies and operationtemperatures to demonstrate the polarization phenomena and the thermally stimulatedeffects. Such complex permittivity measurements may be utilized as a criterion for theservice life prediction of oil field electrical equipment (OFEE. Therefore, by one set ofmeasurements on a small oil volume, data may be provided on the impending termination,or continuation of the transformer oil service life. The oil incorporating cell, attached to theappropriate measuring units, could be described as a complex permittivity sensor. In thiswork, the acquired dielectric data from a great number of operating distribution networkpower transformers were correlated to corresponding physicochemical ones to demonstratethe future potential employment of the proposed measuring technique.

  12. The design, construction, and operation of long-distance high-voltage electricity transmission technologies.

    Energy Technology Data Exchange (ETDEWEB)

    Molburg, J. C.; Kavicky, J. A.; Picel, K. C.

    2008-03-03

    This report focuses on transmission lines, which operate at voltages of 115 kV and higher. Currently, the highest voltage lines comprising the North American power grid are at 765 kV. The grid is the network of transmission lines that interconnect most large power plants on the North American continent. One transmission line at this high voltage was built near Chicago as part of the interconnection for three large nuclear power plants southwest of the city. Lines at this voltage also serve markets in New York and New England, also very high demand regions. The large power transfers along the West Coast are generally at 230 or 500 kV. Just as there are practical limits to centralization of power production, there are practical limits to increasing line voltage. As voltage increases, the height of the supporting towers, the size of the insulators, the distance between conductors on a tower, and even the width of the right-of-way (ROW) required increase. These design features safely isolate the electric power, which has an increasing tendency to arc to ground as the voltage (or electrical potential) increases. In addition, very high voltages (345 kV and above) are subject to corona losses. These losses are a result of ionization of the atmosphere, and can amount to several megawatts of wasted power. Furthermore, they are a local nuisance to radio transmission and can produce a noticeable hum. Centralized power production has advantages of economies of scale and special resource availability (for instance, hydro resources), but centralized power requires long-distance transfers of power both to reach customers and to provide interconnections for reliability. Long distances are most economically served at high voltages, which require large-scale equipment and impose a substantial footprint on the corridors through which power passes. The most visible components of the transmission system are the conductors that provide paths for the power and the towers that keep these

  13. BEHAVIOUR OF BACKFILL MATERIALS FOR ELECTRICAL GROUNDING SYSTEMS UNDER HIGH VOLTAGE CONDITIONS

    Directory of Open Access Journals (Sweden)

    S. C. LIM

    2015-06-01

    Full Text Available Backfill materials like Bentonite and cement are effective in lowering grounding resistance of electrodes for a considerable period. During lightning, switching impulses and earth fault occurrences in medium and high voltage networks, the grounding system needs to handle extremely high currents either for a short duration or prolonged period respectively. This paper investigates the behaviour of bentonite, cement and sand under impulse and alternating high voltage (50Hz conditions. Fulguritic-formation was observed in all materials under alternating high voltage. The findings reveal that performance of grounding systems under high voltage conditions may significantly change from the outcomes anticipated at design stage.

  14. High voltage engineering

    CERN Document Server

    Rizk, Farouk AM

    2014-01-01

    Inspired by a new revival of worldwide interest in extra-high-voltage (EHV) and ultra-high-voltage (UHV) transmission, High Voltage Engineering merges the latest research with the extensive experience of the best in the field to deliver a comprehensive treatment of electrical insulation systems for the next generation of utility engineers and electric power professionals. The book offers extensive coverage of the physical basis of high-voltage engineering, from insulation stress and strength to lightning attachment and protection and beyond. Presenting information critical to the design, selec

  15. Valorisation of grape pomace by the extraction of phenolic antioxidants: Application of high voltage electrical discharges.

    Science.gov (United States)

    Boussetta, N; Vorobiev, E; Deloison, V; Pochez, F; Falcimaigne-Cordin, A; Lanoisellé, J-L

    2011-09-15

    The aim of this study was to optimise the electrically assisted extraction in order to obtain grape pomace extracts with high polyphenols content, which would be potentially interesting for applications as natural antioxidants. High voltage electrical discharges (HVED) were applied for intensification of the extraction. The effects of the energy input, the electrodes distance gap and the liquid-to-solid ratio were studied. Diffusion was then carried out in different mixtures of water and ethanol for one hour at 20, 30, 40 and 60°C. The most efficient extraction was (i) an HVED pre-treatment at 80kJ/kg with an electrodes distance of 5mm in a liquid-to-solid ratio of 5 followed by (ii) a diffusion with 30% ethanol in water at 60°C for 30min. The highest total polyphenols content reached 2.8±0.4gGAE/100gDM with a corresponding antioxidant activity of 66.8±3.1gTEAC/kgDM. The polyphenols extraction rate increased with temperature in accordance to an Arrhenius type of relationship: activation energy of 21.5±1.1kJ/mol for HVED treated systems against 0.5±0.2kJ/mol for untreated ones.

  16. Analysis on electrical characteristics of high-voltage GaN-based light-emitting diodes

    Institute of Scientific and Technical Information of China (English)

    Guo Wei-Ling; Yan Wei-Wei; Zhu Yan-Xu; Liu Jian-Peng; Ding Yan; Cui De-Sheng; Wu Guo-Qing

    2012-01-01

    In order to investigate their electrical characteristics,high-voltage light-emitting-diodes (HV-LEDs) each containing four cells in series are fabricated.The electrical parameters including varying voltage and parasitic effect are studied.It is shown that the ideality factors (IFs) of the HV-LEDs with different numbers of cells are 1.6,3.4,4.7,and 6.4.IF increases linearly with the number of cells increasing.Moreover,the performance of the HV-LED with failure cells is examined.The analysis indicates that the failure cell has a parallel resistance which induces the leakage of the failure cell.The series resistance of the failure cell is 76.8 Ω,while that of the normal cell is 21.3 Ω.The scanning electron microscope (SEM) image indicates that different metal layers do not contact well.It is hard to deposit the metal layers in the deep isolation trenches.The fabrication process of HV-LEDs needs to be optimized.

  17. Effects of High-Voltage Electrical Stimulation in Improving the Viability of Musculocutaneous Flaps in Rats.

    Science.gov (United States)

    Neves, Lais Mara Siqueira das; Guirro, Elaine Caldeira de Oliveira; Albuquerque, Fernanda Luiza de Almeida; Marcolino, Alexandre Marcio

    2016-10-01

    The musculocutaneous flap of the transverse rectus abdominis muscle is a technique used for breast reconstruction, and one of the complications of this procedure is tissue necrosis. The objective of the study is to determine the effect of high-voltage electrical stimulation (HVES) in the transverse rectus abdominis muscle flap in rats. Fourteen rats underwent surgery for obtaining the flap. The rats were distributed into 2 homogeneous groups: group 1 underwent both surgery and the use of HVES, whereas group 2 underwent just the surgery (control). Electrical stimulation was applied immediately after surgery and for 2 consecutive days. The percentage of necrotic area was analyzed using the Image J software, and blood flow was assessed by infrared thermography in different regions of the flap, divided into 4 zones according to the proximity of the pedicle of the inferior epigastric artery. The results were analyzed using a Student t test, where group 1 experienced a necrotic area of 26.2%, and group 2 had an area of 54.5%. Regarding the temperature, the 2 groups showed increase in the minimum and maximum temperature on the fourth postoperative day. The HVES appeared to have a positive influence on the viability of the flap.

  18. Electrical burns in sports fishing: a case report.

    Science.gov (United States)

    Valença-Filipe, R; Egipto, P; Horta, R; Braga, J M; Costa, J; Silva, A

    2014-11-01

    Electrical burns are among the most devastating types of burns, with wide-ranging injuries. They can sometimes occur in the context of fishing, usually involving high voltages. The authors present the case of a 59-year-old-man who suffered a sports accident during a fishing competition, with the formation of an electrical arc due to proximity of the fishing rod and high voltage cables. He presented burns affecting 3% of TBSA, third degree deep burns on trunk and left hand; no signs of cardiac injury. He was admitted to our Burn Unit for monitoring, care dressing and surgical treatment; complete wound healing was achieved after 24 days. Due to its relatively small share among burns, published data on electrical injuries and fishing remain scarce, and differ in patient collectives due to infrastructural or environmental differences. The authors are not aware of published specific reports on electrical burns in sports fishing practice, like the case here presented. The authors want to alert for potential medical, social and economic consequences of this type of sports accidents that could be entirely avoidable with some preventive measures.

  19. Environmental justice: a contrary finding for the case of high-voltage electric power transmission lines.

    Science.gov (United States)

    Wartenberg, Daniel; Greenberg, Michael R; Harris, Gerald

    2010-05-01

    Environmental justice is the consideration of whether minority and/or lower-income residents in a geographic area are likely to have disproportionately higher exposures to environmental toxins than those living elsewhere. Such situations have been identified for a variety of factors, such as air pollution, hazardous waste, water quality, noise, residential crowding, and housing quality. This study investigates the application of this concept to high-voltage electric power transmission lines (HVTL), which some perceive as a health risk because of the magnetic fields they generate, and also as esthetically unpleasing. We mapped all 345 kV and higher voltage HVTL in New York State and extracted and summarized proximate US Census sociodemographic and housing characteristic data into four categories on the basis of distances from HVTL. Contrary to our expectation, people living within 2000 ft from HVTL were more likely to be exposed to magnetic fields, white, of higher income, more educated and home owners, than those living farther away, particularly in urban areas. Possible explanations for these patterns include the desire for the open space created by the rights-of-way, the preference for new homes/subdivisions that are often located near HVTL, and moving closer to HVTL before EMFs were considered a risk. This study suggests that environmental justice may not apply to all environmental risk factors and that one must be cautious in generalizing. In addition, it shows the utility of geographical information system methodology for summarizing information from extremely large populations, often a challenge in epidemiology.

  20. Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines

    Directory of Open Access Journals (Sweden)

    Wafa Tourab

    2016-06-01

    Conclusion: We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.

  1. Project resumes: biological effects from electric fields associated with high-voltage transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-01-01

    Abstracts of research projects are presented in the following areas: measurements and special facilities; cellular and subcellular studies; physiology; behavior; environmental effects; modeling, scaling and dosimetry; and high voltage direct current. (ACR)

  2. AN ASSESSMENT OF HIGH-VOLTAGE DC ELECTRICAL POWER IN AIRCRAFT ELECTRICAL SYSTEMS.

    Science.gov (United States)

    If the presently installed three-phase ac transmission system on aircraft were replaced by a higher voltage dc ( HVDC ) transmission using a ground...from one- to two-thirds of the total electrical system weight. HVDC may have some disadvantages such as higher short-circuit currents, some increase in

  3. High voltage electric potentials to enhance brain-derived neurotrophic factor levels in the brain.

    Science.gov (United States)

    Yanamoto, Hiroji; Nakajo, Yukako; Kataoka, Hiroharu; Iihara, Koji

    2013-01-01

    Development of a safe method to increase brain-derived neurotrophic factor (BDNF) levels in the brain is expected to enhance learning and memory, induce tolerance to cerebral infarction or tolerance to depressive state, improve glucose metabolism, and suppress appetite and body weight. We have shown that repetitive applications of high-voltage electric potential (HELP) to the body increase BDNF levels in the brain, improving learning and memory in mice. Here, we investigated the effects of HELP treatment for a chronic period on the BDNF levels in the mouse brain, and on body weight in mice and humans. Adult mice were exposed to 3.1 or 5.4 kV HELP (on the body), 5 h a day for 24 weeks, and BDNF levels in the brain and alterations in body weight were analyzed. Humans [age, 53.2 ± 15.5 years old; BMI, 27.8 ± 5.6 (mean ± SD, n = 6)] were exposed to 3.9 kV HELP (on the body) for 1 h a day, continuing for 33 months (2.8 years) under the monitor of body weight. In mice, the HELP application elevated BDNF levels in the brain at least temporarily, affecting body weight in a voltage- and time-dependent manner. In humans, the HELP treatment reduced body weight compared to the pretreated initial values without any aversive effects (p BDNF, and 5.4 kV HELP was considered as excessive. HELP with an appropriate voltage can be utilized to increase BDNF levels in the brain for a prolonged period. We anticipate further investigations to clarify the effect of the optimal-leveled HELP therapy on memory disturbances, neurological deficits after stroke, depression, diabetes, obesity and metabolic syndrome.

  4. Evaluation of the effectiveness of neurofeedback in the reduction of Posttraumatic stress disorder (PTSD in a patient following high-voltage electric shock with the use of ERPs

    Directory of Open Access Journals (Sweden)

    Anna Chrapusta

    2015-09-01

    Full Text Available Background. The aim of our research was an evaluation of the effectiveness of neurofeedback in reducing the symptoms of Post-trauma stress disorder (PTSD, which had developed as a result of a high-voltage electric burn to the head. Quantitative EEG (QEEG and Event related potentials (ERPs were utilised in the evaluation. Case study. A 21-year-old patient, experienced 4[sup]th[/sup] degree burns to his head as a result of a high-voltage electric burn. The patient was repeatedly operated on and despite the severity of the injuries was to recover. However the patient complained of flashbacks, difficulties with sleeping as well as an inability to continue work in his given profession. Specialist tests were to show the presence within him of PTSD. As a result of which the patient was provided with neurofeedback therapy. The effectiveness of this therapy in the reduction (eradication of the symptoms of PTSD were evaluated through the utilisation of qantitative eeg (Qeeg and event related potentials (ERPs. Results. It was found that in the first examination that ERPs display the most significant deviations from the reference in the two components: (1 the one component is generated within the cingulate cortex. The pattern of its deviation from the norms is similar to that found in a group of OCD patients. In contrast to healthy subjects the component repeats itself twice; (2 the second component is generated in the medial prefrontal cortex. Its pattern (neuromarker is similar to that found in PTSD patients. There is a delay in the late part of the component, which probably reflects the flashbacks. In the second examination, after neurofeedback training, the ERPs were similar to the norm. The patient returned to work. Conclusions. Chronic PTSD developed within the patient as a result of a high-voltage electric burn. The application of a method of therapy (neurofeedback resulted in the withdrawal of the syndrome symptoms. ERPs in a GO/NOGO task can be

  5. The effect of high voltage, high frequency pulsed electric field on slain ovine cortical bone.

    Science.gov (United States)

    Asgarifar, Hajarossadat; Oloyede, Adekunle; Zare, Firuz

    2014-04-01

    High power, high frequency pulsed electric fields known as pulsed power (PP) has been applied recently in biology and medicine. However, little attention has been paid to investigate the application of pulse power in musculoskeletal system and its possible effect on functional behavior and biomechanical properties of bone tissue. This paper presents the first research investigating whether or not PP can be applied safely on bone tissue as a stimuli and what will be the possible effect of these signals on the characteristics of cortical bone by comparing the mechanical properties of this type of bone pre and post expose to PP and in comparison with the control samples. A positive buck-boost converter was applied to generate adjustable high voltage, high frequency pulses (up to 500 V and 10 kHz). The functional behavior of bone in response to pulse power excitation was elucidated by applying compressive loading until failure. The stiffness, failure stress (strength) and the total fracture energy (bone toughness) were determined as a measure of the main bone characteristics. Furthermore, an ultrasonic technique was applied to determine and comprise bone elasticity before and after pulse power stimulation. The elastic property of cortical bone samples appeared to remain unchanged following exposure to pulse power excitation for all three orthogonal directions obtained from ultrasonic technique and similarly from the compression test. Nevertheless, the compressive strength and toughness of bone samples were increased when they were exposed to 66 h of high power pulsed electromagnetic field compared to the control samples. As the toughness and the strength of the cortical bone tissue are directly associated with the quality and integrity of the collagen matrix whereas its stiffness is primarily related to bone mineral content these overall results may address that although, the pulse power stimulation can influence the arrangement or the quality of the collagen network

  6. Automatic Distance Monitoring System of Contact Connections in High Voltage Equipment of Electric Power Lines

    Directory of Open Access Journals (Sweden)

    M. Diachenko

    2013-01-01

    Full Text Available The developed automatic distance monitoring system of contact connections in high voltage equipment is based on technology of sensor circuits. The paper shows application of control methodology for contact connections in accordance with time rate of conductor temperature changes and contact connection and also direct measurement of transient resistance.

  7. THE EFFECT OF LIGHTNING ON HIGH VOLTAGE ELECTRICAL SUBSTATIONS’ LOW VOLTAGE SYSTEMS

    Directory of Open Access Journals (Sweden)

    M. I. Fursanov

    2016-01-01

    Full Text Available The article presents the results of studies of the effects of lightning on low voltage systems of high voltage electrical substations with outdoor switchgears of 110 kV. The topicality of research is associated with a wide spreading of such substations as well as with a high reliability requirements of their work and, also, with their widespread distribution and high probability of lightning strikes to the substation or around it. The highest probable and the most dangerous effects of lightning on low voltage systems of a substation are determined on the basis of critical review and special literature analysis and, also, of systematization of practical information that had been collected during the survey of operating substations. Adequate physical models were developed for the list of hazardous effects based on physical processes of lightning. A model of each effect was studied on the basis of the sensitivity theory. The accuracy and adequacy of the models were verified by means of comparison of calculation results for the models under investigation with the results of calculations fulfilled in accordance with specialized programs, as well as from practical or theoretical data obtained by other authors. The factors that had been included in the models were studied and were defined in accordance with their nature (natural or artificial, the range of possible values in a substation was determined; the coefficients of elasticity were calculated. The obtained results enable to ascertain the contribution of the factor in the effect of lightning and the ability to control the factor. The relationship between the factors and the effects of lightning are shown as graphs. For practical application the information, obtained as the result of the research, was organized in the form of checklists that can be applied when collecting baseline information to develop the lightning protection of the substation, to examine the existing lightning protection, to

  8. Session 4: Heterogeneous catalysts formation under high-voltage electric discharge

    Energy Technology Data Exchange (ETDEWEB)

    Kuzmina, R.I.; Sevostyanov, V.P.; Ivanova, Y.V.; Dogadina, N.V.; Rakitin, S.A. [Saratov State Univ. (Russian Federation)

    2004-07-01

    Energetic and environmental problems of today place heavy demands on both technologies of motor fuels production and exhaust gases cleaning. In this connection, main technological processes of petrochemistry and environmental catalysis require high-efficient and selective catalysts. The essence of EHB is short-time (1-2 {mu}sec) intense impact on an object to be processed that takes place under high-voltage pulse electric discharge in condensed matter. This paper is devoted to formation of aluminum-platinum-copper catalysts of hydrocarbons reforming and aluminum-platinum-nickel catalysts of redox cleaning of exhausted gases. In both cases catalyst formation takes place under EHB in steep media where catalyst carrier is set in. EHB treatment is fulfilled under discharge voltage 25-30 kV and variable electrode gap in the range from 1 to 30 mm. Under the treatment, 'carrier + steep solution' system is exposed to the number of acting factors, namely ultraviolet, cavitation and percussion waves, electric and magnetic influences. In our research, EHB was imposed to heterogeneous system of 2.5% Cu/Al{sub 2}O{sub 3} and water solution of H{sub 2}PtCl{sub 6}. It is shown that EHB catalyst provides yield of the target product (benzene) at a level of about 64 % (w.) under 550 C in comparison of 30.8 % (w.) level provided by traditional Cu,Pt/Al{sub 2}O{sub 3} catalyst. It is necessary to note change of n-hexane conversion mechanism in presence of aluminum-platinum-copper catalyst (EHB). Catalysate contains nearly no products of C5-dehydrocyclization (C5-DHC) whereas their yield reaches 20 % (w.) for traditional catalysts under similar conditions (550 C). This fact points to formation of aromatic hydrocarbons from n-paraffins by direct C6-dehydrocyclization omitting C5-dehydrocyclization and isomerization. EHB catalyst is characterized by drop in hydrocracking reaction output that increases selectivity of n-hexane reforming in aromatization. In order to find out EHB

  9. Design of 154 kV Extra-High-Voltage Prototype SF6 Bushing for Superconducting Electric Power Applications

    Science.gov (United States)

    Koo, Ja-yoon; Seong, Jae-gyu; Hwang, Jae-sang; Lee, Bang-wook; Lee, Sang-hwa

    2012-09-01

    One of the critical components to be developed for high-voltage superconducting devices, such as superconducting transformers, cables, and fault current limiters, is a high-voltage bushing to supply a high current to devices without insulation difficulties in cryogenic environments. Unfortunately, suitable bushings for high-temperature-superconductivity (HTS) equipment have not been fully developed to address cryogenic insulation issues. As a fundamental step towards developing the optimum design of the 154 kV prototype SF6 bushing of HTS devices, the puncture and creepage breakdown voltages of glass-fiber-reinforced-plastic (GFRP) were analyzed with a variety of configurations of electrodes and gap distances in the insulation material. And design factors of high-voltage cryogenic bushings were obtained from the result of tests. Finally, the withstand voltage tests of manufacturing a 154 kV extra-high-voltage (EHV) prototype bushing has been performed. Consequently, we verified the insulation level of the newly designed 154 kV EHV cryogenic prototype bushings for superconducting electric power applications.

  10. High voltage test techniques

    CERN Document Server

    Kind, Dieter

    2001-01-01

    The second edition of High Voltage Test Techniques has been completely revised. The present revision takes into account the latest international developments in High Voltage and Measurement technology, making it an essential reference for engineers in the testing field.High Voltage Technology belongs to the traditional area of Electrical Engineering. However, this is not to say that the area has stood still. New insulating materials, computing methods and voltage levels repeatedly pose new problems or open up methods of solution; electromagnetic compatibility (EMC) or components and systems al

  11. A Novel Electrical Insulating Material for 275 kV High-Voltage HTS Cable with Low Dielectric Loss

    Science.gov (United States)

    Hayakawa, N.; Nishimachi, S.; Maruyama, O.; Ohkuma, T.; Liu, J.; Yagi, M.

    2014-05-01

    In the case of high temperature superconducting (HTS) power transmission cables at high voltage operation, the electrical insulation technique in consideration of the dielectric loss reduction becomes crucial. In this paper, we focused on a Tyvek/polyethylene (PE) sheet, instead of the conventional polypropylene laminated paper (PPLP). We obtained the dielectric characteristics (epsilonr, tanδ) and partial discharge inception strength (PDIE) of PPLP, Tyvek and Tyvek/PE. We pointed out that the dielectric loss of 275 kV HTS cable with Tyvek/PE insulation will be reduced to 21 % of that with PPLP, and the total electrical loss including the AC loss will be reduced to 41 %.

  12. The Effect of Current-Limiting Reactors on the Tripping of Short Circuits in High-Voltage Electrical Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Volkov, M. S.; Gusev, Yu. P., E-mail: GusevYP@mpei.ru; Monakov, Yu. V.; Cho, Gvan Chun [National Research University “Moscow Power Engineering Institute,” (Russian Federation)

    2016-01-15

    The insertion of current-limiting reactors into electrical equipment operating at a voltage of 110 and 220 kV produces a change in the parameters of the transient recovery voltages at the contacts of the circuit breakers for disconnecting short circuits, which could be the reason for the increase in the duration of the short circuit, damage to the electrical equipment and losses in the power system. The results of mathematical modeling of the transients, caused by tripping of the short circuit in a reactive electric power transmission line are presented, and data are given on the negative effect of a current-limiting resistor on the rate of increase and peak value of the transient recovery voltages. Methods of ensuring the standard requirements imposed on the parameters of the transient recovery voltages when using current-limiting reactors in the high-voltage electrical equipment of power plants and substations are proposed and analyzed.

  13. Impact of pulsed-electric field and high-voltage electrical discharges on red wine microbial stabilization and quality characteristics.

    Science.gov (United States)

    Delsart, C; Grimi, N; Boussetta, N; Miot Sertier, C; Ghidossi, R; Vorobiev, E; Mietton Peuchot, M

    2016-01-01

    In this study, pulsed-electric fields (PEF) and high-voltage electrical discharges (HVED) are proposed as new techniques for the microbial stabilization of red wines before bottling. The efficiency of the treatment was then evaluated. PEF and HVED-treatments have been applied to wine for the inactivation of Oenococcus oeni CRBO 9304, O. oeni CRBO 0608, Pediococcus parvulus CRBO 2.6 and Brettanomyces bruxellensis CB28. Different treatment times (1, 2, 4, 6, 8 and 10 ms) were used at 20 kV cm(-1) for the PEF treatments and at 40 kV for the HVED treatments, which correspond to applied energies from 80 to 800 kJ l(-1) . The effects of the treatments on the microbial inactivation rate and on various characteristics of red wines (phenolic composition, chromatic characteristics and physico-chemical parameters) were measured. The application of PEF or HVED treatments on red wine allowed the inactivation of alteration yeasts (B. bruxellensis CB28) and bacteria (O. oeni CRBO 9304, O. oeni CRBO 0608 and P. parvulus CRBO 2.6). The electric discharges at 40 kV were less effective than the PEF even after 10 ms of treatments. Indeed, 4 ms of PEF treatment at 20 kV cm(-1) were sufficient to inactivate all micro-organisms present in the wines. Also, the use of PEF had no negative impact on the composition of wines compared to the HVED treatments. Contrary to PEF, the phenolics compounds were degraded after the HVED treatment and the physico-chemical composition of wine were modified with HVED. PEF technology seems to be an interesting alternative to stabilize microbiologically wines before bottling and without modifying their composition. This process offers many advantages for winemakers: no chemical inputs, low energy consumption (320 kJ l(-1) ), fast (treatment time of 4 ms) and athermal (ΔT ≈ 10°C). © 2015 The Society for Applied Microbiology.

  14. PAIN RELIFE DURING LABOR: EFFICACY OF SKIN ELECTRICAL STIMULATION (TENS, INTERFERENTIAL, HIGH VOLTAGE

    Directory of Open Access Journals (Sweden)

    Z SHAHSHAHAN

    2001-09-01

    Full Text Available Introduction. Pain during labor is a physiologic pain cause anxity in mothers.There are many procedures to make labor painless in mothers. This study compare some of these methods. Methods. The study was carried out as a double blinded clinical trial on 149 pregnant women who refered to the Beheshti hospital (affiliated to IUMSHSduring 1998 to 2001 with labor pain. The term gravid women were divided randomly to five group. Control group (30 Cases,Placebo group (30 Cases, TENS (30 Cases, High voltage (26 Cases and Interferential (30 Cases.Pain level was measured with modified Mc Gill and Visual Analog Scale (VAS questionnaire at 4, 6, 8 and 10 Cm cervical dilation. Results. Difference was seen between TENS with placebo & control (P<0.05. The average time of active phase was significantly shorter (40-85 minute in Interferential group in comparison with other groups. Discussion. This is probably an indication of augmentation of contraction and may be this kind of wave could be used in abnormal uterine contraction and abnormal progress of labor.

  15. Electrical discharges under high voltage on surface of Silica-Nickel ceramic composites

    Energy Technology Data Exchange (ETDEWEB)

    Jankowiak, A.; Blanchart, P. [Groupement d' Etude des Materiaux Heterogenes (GEMH), ENSCI, 87065 Limoges (France)

    2004-12-01

    Strong electrical breakdowns on surface of Silica-Nickel cermets are obtained under pulsed electric field. The electric field is significantly lower than for breakdowns at a similar air gap under the same atmosphere pressure. This hot plasma-like process can be used for gas or liquid ignition. Processes follow the Paschen's and the Fowler-Nordheim's laws at surface micro-protrusions, when the current percolates through the composite material. (Abstract Copyright [2004], Wiley Periodicals, Inc.)

  16. Proposal and Development of a High Voltage Variable Frequency Alternating Current Power System for Hybrid Electric Aircraft

    Science.gov (United States)

    Sadey, David J.; Taylor, Linda M.; Beach, Raymond F.

    2017-01-01

    The development of ultra-efficient commercial vehicles and the transition to low-carbon emission propulsion are seen as strategic thrust paths within NASA Aeronautics. A critical enabler to these paths comes in the form of hybrid electric propulsion systems. For megawatt-class systems, the best power system topology for these hybrid electric propulsion systems is debatable. Current proposals within NASA and the Aero community suggest using a combination of alternating current (AC) and direct current (DC) for power generation, transmission, and distribution. This paper proposes an alternative to the current thought model through the use of a primarily high voltage AC power system, supported by the Convergent Aeronautics Solutions (CAS) Project. This system relies heavily on the use of doubly-fed induction machines (DFIMs), which provide high power densities, minimal power conversion, and variable speed operation. The paper presents background on the activity along with the system architecture, development status, and preliminary results.

  17. The Electrostatic Wind Energy Converter: electrical performance of a high voltage prototype

    NARCIS (Netherlands)

    Djairam, D.

    2008-01-01

    Wind energy is converted to electrical energy by letting the wind move charged particles against the direction of an electric field. The advantage of this type of conversion is that no rotational movement, which occurs in conventional wind turbines, is required. An electrostatic wind energy

  18. Biological effects from electric fields associated with high voltage transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    1983-11-01

    Efforts during the past year by the US Department of Energy and the Electric Power Research Institute-funded laboratories to investigate the biological effects from electric fields are described in resume form. Investigations generally have been summarized with objectives, accomplishments of the past year, and some indication of projected studies.

  19. Cardiac thrombus developing after an accidental high-voltage electric shock in a child.

    Science.gov (United States)

    Akın, Alper; Bilici, Meki; Demir, Fikri; Gözü Pirinççioğlu, Ayfer; Yavuz, Celal

    2015-01-01

    Electric shock is a condition that may affect various organ systems and potentially cause death. Cardiac findings vary from asymptomatic mild injury to fatal myocardial involvement. Herein we present a five-year-old boy with a cardiac thrombus developing after an accidental electrical shock. Cardiac arrhythmias and evidence of ischemia have been reported after electric shock; we were, however, unable to identify an earlier case report of intracardiac thrombosis related to electric shock. Findings such as elevated cardiac enzymes and systolic dysfunction, which indicate myocardial damage following electric shock, were present in our patient. We think that the cardiac thrombus might have resulted from the myocardial damage and the slowed intracardiac blood flow related to systolic dysfunction. As the thrombus was thought to have been formed through known mechanisms, it was treated traditionally. However, further data regarding the etiology and management of such thrombi is needed.

  20. Electrical and structural R&D activities on high voltage dc solid insulator in vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Pilan, N., E-mail: nicola.pilan@igi.cnr.it [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Marcuzzi, D.; Rizzolo, A.; Grando, L.; Gambetta, G. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Rosa, S. Dalla [Umicore – Italbras S.p.A., Strada del Balsego, n.6, 36100 Vicenza (Italy); Kraemer, V.; Quirmbach, T. [FRIATEC Ceramics Division, Steinzeugstrasse 50, 68229 Mannheim (Germany); Chitarin, G. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Gobbo, R.; Pesavento, G. [DII, Università di Padova, v. Gradenigo 6/A, I-35131 Padova (Italy); De Lorenzi, A.; Lotto, L.; Rizzieri, R.; Fincato, M.; Romanato, L.; Trevisan, L.; Cervaro, V.; Franchin, L. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy)

    2015-10-15

    Highlights: • A thorough R&D activity on the MITICA post insulator prototypes is being carried out. • The design has been numerically verified considering both mechanical and electrical aspects. • Experimental validation has been started, with positive results in both involved fields. • Alternative design solutions thickness have been proposed and successfully tested. - Abstract: This paper describes the R&D work performed in support of the design of the alumina insulators for the MITICA Neutral Beam Injector. The ceramic insulators are critical elements, both from the structural and electrical point of view, of the 1 MV electrostatic accelerator of the MITICA injector, as they are required to sustain both the mechanical loads due to the cantilevered weight of the ion source and the high electric field between the accelerator grids. This paper presents the results of numerical simulations and experimental tests on prototypes that have been carried out to validate the insulator design under realistic operating conditions.

  1. Mineral Liberation of Magnetite-Precipitated Copper Slag Obtained via Molten Oxidation by Using High-Voltage Electrical Pulses

    Science.gov (United States)

    Fan, Yong; Shibata, Etsuro; Iizuka, Atsushi; Nakamura, Takashi

    2016-10-01

    Our proposed method, i.e., a controlled molten oxidation process under 1 vol pct oxygen, leads to selective precipitation of magnetite in a copper smelter slag for downstream iron separation. In the present study, the preroasted magnetite precipitated copper slag was treated via magnetite liberation, which was realized by using high-voltage electrical pulses. The mineral distribution was determined by using a laser microscope and its image analysis; and it revealed that the 100- µm under-sieve product contains approximately 70 pct of liberated mineral particles. The study affirms the positive outcome of using this new technology for comminution to obtain micrometer-scale particles that yield monominerals via selective liberation. Using magnetic separation, iron was capable of finally separating into high- and low-iron-bearing concentrate and tailing that can be used in specific applications.

  2. Microstructure Investigation of 13Cr-2Mo ODS Steel Components Obtained by High Voltage Electric Discharge Compaction Technique

    Directory of Open Access Journals (Sweden)

    Igor Bogachev

    2015-11-01

    Full Text Available Refractory oxide dispersion strengthened 13Cr-2Mo steel powder was successfully consolidated to near theoretical density using high voltage electric discharge compaction. Cylindrical samples with relative density from 90% to 97% and dimensions of 10 mm in diameter and 10–15 mm in height were obtained. Consolidation conditions such as pressure and voltage were varied in some ranges to determine the optimal compaction regime. Three different concentrations of yttria were used to identify its effect on the properties of the samples. It is shown that the utilized ultra-rapid consolidation process in combination with high transmitted energy allows obtaining high density compacts, retaining the initial structure with minimal grain growth. The experimental results indicate some heterogeneity of the structure which may occur in the external layers of the tested samples due to various thermal and electromagnetic in-processing effects. The choice of the optimal parameters of the consolidation enables obtaining samples of acceptable quality.

  3. The Usefulness of Bone Scan in Electric Burns

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyung; So, Yong Seon; Kweon, Ki Hyeon; Han, Sang Woong; Kim, Seok Hwan; Kim, Jong Soon; Han, Seung Soo [Hanil Hospital, Seoul (Korea, Republic of)

    1996-03-15

    Bone scan is known to be an effective tool for observing the state of soft tissues and bones of electric burn patients. It is also used for observing the progress of patients after debridement or skin graft as well as determining to amputate specific body parts. To evaluate bone scan's role in electric burn, we analyzed bone scan 37 patients with electric burn. Among the 37 patients, 8 of 37 were injured in low voltage and 29 of them in high voltage. 27 patients received the electrical input through the hand, 6 through the scalp, 2 through the shoulder, 1 through the left chest wall and 1 through the left inguinal area. Among 29 patients received high voltage, 22 patients had the electrical output through the foot, 3 through the hand, 2 through the shoulder, 1 through the buttock and 1 through the left chest wall. Bone scans revealed cellulitis in 37 patients with 47 sites, osteomyelitis in 15 patients with 15 sites and bone defects in 4 patients with 4 sites. In 4 patients with skin graft or skin flap, follow up bone scan showed improvements of bony uptake in preoperatively bony defect area and all of them were healed without complication There were 2 cases in which uptake increased in the myocardium, 1 in the liver and 6 in the kidney, however, scrum calcium level, EKG, cardiac enzyme, liver and renal function tests were normal. In conclusion, bone scans are helpful in the assessment of injury sites after electrical insult and in differential diagnosis of cellulitis and osteomyelitis. It is also useful tool of assessment after skin graft or skin flap, however, it should be further evaluated about internal organ damage.

  4. Design and Experiments of the High Voltage Pulsed Electric Fields Sterilization System

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xihai; FANG Junlong; SHEN Weizheng

    2008-01-01

    This experiment designed the pulsed electric fields (PEF) of high intensity of 100 kV. cml sterilization system. Fluorescent pseudomonas as target cell was operated 180 s in the PEF. By observing the difference of the bacteria before and after the disposal by TEM, it is found that the cell wails of the treated bacteria were broken. Irreversible perforations were formed on the cell membrane. The cell inclusions and cell fragments were leaked. The cell died as a result. The results showed that the PEF sterilization system designed can be used for liquid food sterilization experiments.

  5. High-voltage Pulsed Electric Field in.Food Industry%食品高压脉冲电场杀菌技术

    Institute of Scientific and Technical Information of China (English)

    袁丽佳; 何博; 姜彬; 尤涛

    2011-01-01

    High-voltage pulsed electric field is one of the most popular methods in food process. The mechanism of high-voltage pulsed electric field, the device of high-vo]tage pulsed electric field , and the application of it are introduced.%高压脉冲电场(high-voltage pulsed electric field,HPEF)杀菌技术是目前国际上最热门的食品加工技术之一,本文介绍了高压脉冲电场杀菌技术的基本机理,杀菌装置,以及对该技术在食品加工中应用的介绍。

  6. Simple flaps for reconstruction of pediatric scalp defects after electrical burn

    Institute of Scientific and Technical Information of China (English)

    Mohamed Makboul; Mohamed Abdel-Rahim

    2013-01-01

    Objective:To analyze the management of high-voltage electrical burn injury of the scalp in our hospital.Methods:This study involved 10 patients who suffered from high-voltage electrical burn injury of the scalp.Scalp reconstruction was done by different modalities according to the size and location of the defect.Results:Complete flap viability was achieved in all the cases.We had one case of gapped wound which was managed only by dressing.Widening of the scar was found in 2 cases.Conclusion:Rotation,advancement and transposition scalp flaps are used for reconstructing scalp defects caused by electrical burn.The choice of ideal flaps for reconstruction depends upon the size and site of scalp defect.

  7. Sulfone-carbonate ternary electrolyte with further increased capacity retention and burn resistance for high voltage lithium ion batteries

    Science.gov (United States)

    Xue, Leigang; Lee, Seung-Yul; Zhao, Zuofeng; Angell, C. Austen

    2015-11-01

    Safety and high energy density are the two focus issues for current lithium ion batteries. For safety, it has been demonstrated that sulfone electrolytes are much less flammable than the prevailing all-carbonate type, and they are also promising for high voltage batteries due to the high oxidization resistance. However, the high melting points and viscosities greatly restricted their application. Based on our previous work on use of fluidity-enhancing cosolvents to make binary sulfone-carbonate electrolytes, we report here a three-component system that is more conductive and should be even less flammable while additionally having better low temperature stability. The conductivity-viscosity relations have been determined for this electrolyte and are comparable to those of the "standard" carbonate electrolyte. The additional component also produces much improved capacity retention for the LiNi0.5Mn1.5O4 cathode. As with carbonate electrolytes, increase of temperature to 55 °C leads to rapid capacity decrease during cycling, but the capacity loss is due to the salt, not the solvent. The high discharge capacity observed at 25 °C when LiBF4 replaces LiPF6, is fully retained at 55 °C.

  8. New Breakdown Electric Field Calculation for SF6 High Voltage Circuit Breaker Applications

    Institute of Scientific and Technical Information of China (English)

    Ph.ROBIN-JOUAN; M.YOUSFI

    2007-01-01

    The critical electric fields of hot SF6 are calculated including both electron and ion kinetics in wide ranges of temperature and pressure,namely from 300 K up to 4000 K and 2 atmospheres up to 32 atmospheres respectively.Based on solving a multi-term electron Boltzmann equation the calculations use improved electron-gas collision cross sections for twelve SF6 dissociation products with a particular emphasis on the electron-vibrating molecule interactions.The ion kinetics is also considered and its role on the critical field becomes non negligible as the temperature is above 2000 K.These critical fields are then used in hydrodynamics simulations which correctly predict the circuit breaker behaviours observed in the case of breaking tests.

  9. Investigations of the electrical breakdown properties of insulator materials used in high voltage vacuum diodes

    Energy Technology Data Exchange (ETDEWEB)

    Shurter, R.P.; Carlson, R.L.; Melton, J.G.

    1993-08-01

    The Injector for the proposed Dual-Axis Radiographic Hydrodynamic Testing (DARHT) Facility at Los Alamos utilizes a monolithic insulator deployed in a radial configuration. The 1.83-m-diam {times} 25.4-cm-thick insulator with embedded grading rings separates the output oil transmission line from the vacuum vessel that contains the re-entrant anode and cathode assemblies. Although much work has been done by the pulse power community in studying surface flash-over of insulating materials used in both axial and radial configurations, dendrite growth at the roots of grading rings embedded in materials suitable for very large insulators is less well characterized. Degradation of several acrylic insulators has been observed in the form of dendrites growing at the roots of the grading rings for large numbers (100`s) of pulses on the prototype DARHT Injector and other machines using similar radial geometries. In a few cases, these dendrites have led to catastrophic bulk breakdown of the acrylic between two grading rings making the insulator a costly loss. Insulating materials under investigation are acrylic (Lucite), epoxy (Furane), and cross-linked polystyrene (Rexolite); each of these materials has its own particular mechanical and electrical merits. All of these materials have been cast and machined into the required large size for the Injector. Test methods and the results of investigations into the breakdown strength of various interface geometries and the susceptibility of these materials to dendrite growth are reported.

  10. Electrical Power Supply to Offshore Oil Installations by High Voltage Direct Current Transmission

    Energy Technology Data Exchange (ETDEWEB)

    Myhre, Joergen Chr.

    2001-07-01

    This study was initiated to investigate if it could be feasible to supply offshore oil installations in the North Sea with electrical power from land. A prestudy of alternative converter topologies indicated that the most promising solution would be to investigate a conventional system with reduced synchronous compensator rating. The study starts with a summary of the state of power supply to offshore installations today, and a short review of classical HVDC transmission. It goes on to analyse how a passive network without sources influences the inverter. The transmission, with its current controlled rectifier and large inductance, is simulated as a current source. Under these circumstances the analysis shows that the network frequency has to adapt in order to keep the active and reactive power balance until the controllers are able to react. The concept of firing angle for a thyristor is limited in a system with variable frequency, the actual control parameter is the firing delay time. Sensitivity analysis showed some astonishing consequences. The frequency rises both by an increase in the active and in the reactive load. The voltage falls by an increase in the active load, but rises by an increase in the inductive load. Two different control principles for the system of inverter, synchronous compensator and load are defined. The first takes the reference for the firing delay time from the fundamental voltage at the point of common coupling. The second takes the reference for the firing delay time from the simulated EMF of the synchronous compensator. Of these, the second is the more stable and should be chosen as the basis for a possible control system. Two simulation tools are applied. The first is a quasi-phasor model running on Matlab with Simulink. The other is a time domain model in KREAN. The time domain model is primarily used for the verification of the quasi-phasor model, and shows that quasi-phasors is still a valuable tool for making a quick analysis

  11. Electrical burns of the abdomen

    Directory of Open Access Journals (Sweden)

    Rakesh Kumar Srivastava

    2013-01-01

    Full Text Available A 35-year-old male farmer came in contact with 11,000 volts high tension electric wire and sustained full thickness burn wounds over scapula, upper limb and anterior abdominal wall along with perforation of the intestine. Patient was initially managed conservatively in general surgery ward and was referred to us after 3 days with necrosis of the burned skin and muscles over the shoulder and abdomen. Patient was initially managed conservatively and then thorough debridement of the necrotic skin over the left shoulder and upper arm was done and the area was split skin grafted. Patient developed enterocutaneous fistula, which healed over a period of 8 weeks. The granulating wound over the abdomen was also skin grafted and patient was discharged after 18 days. About 4 months, after the discharge patient presented with ventral hernia. Repair of ventral hernia by synthetic mesh application and reconstruction of the abdominal wall with a free tensor fascia lata flap was done over the mesh, but the flap failed. Then after debridement two random pattern transposition skin flaps, one from the right upper and another from the left lower abdomen were transposed over the abdominal wound and donor area was skin grafted. Patient was discharged after 17 days.

  12. High voltage energy storage system design for a parallel-through-the-road plug-in hybrid electric vehicle

    Science.gov (United States)

    Belt, Bryan Whitney D.

    A parallel-through-the-road (PTTR) plug-in hybrid electric vehicle (PHEV) pairs an engine powering the front wheels of a vehicle with an electric motor powering the rear wheels. This arrangement gives the flexibility of being able to operate the vehicle in an all-electric mode, an all biodiesel mode, or a combination of both to create maximum power. For this work, a 1.7 L CIDI engine running on biodiesel will be the engine being used and a 103 kW Magna motor will power the rear wheels. In order to power the motor, a high voltage (HV) energy storage system (ESS) needs to be designed and integrated into the vehicle. The goal for the mechanical design of the ESS is to create a structure that will enclose all of the batteries and battery control modules to protect them from environmental factors such as dirt and water as well as to prevent them from becoming dislodged in the event of a collision. The enclosure will also serve as a means to protect the consumer from the dangers of HV. The mechanical design also entailed designing a cooling system that will keep the batteries operating in an acceptable temperature range while they are charging and discharging. The electrical design focused on designing a HV system that could adequately supply enough current flow to each component to meet the peak loading condition yet be able to disconnect should a fault occur to prevent component damage. The system was also designed with safety in mind. Controllers will constantly be monitoring both the HV and LV systems to make sure that each is isolated from the other. Should a controller detect a problem, it will disconnect the HV system. The electrical system will have a high voltage interlock loop (HVIL). The HVIL will be a continuous LV circuit that passes through every HV connector and various switches, so that, if a connector is unplugged or a switch is flipped, the circuit will open. A controller will be monitoring the HVIL for LV. Should it not detect LV, the controller will

  13. Duration of Electrically Induced Atrial Fibrillation Is Augmented by High Voltage of Stimulus with Higher Blood Pressure in Hypertensive Rats

    Directory of Open Access Journals (Sweden)

    Tomomi Nagayama

    2014-01-01

    Full Text Available Objective. Many previous clinical studies have suggested that atrial fibrillation (AF is closely associated with hypertension. However, the benefits of antihypertensive therapy on AF are still inconsistent, and it is necessary to explore the factors augmenting AF in hypertensive rats. The aim of the present study was to investigate the correlation between arterial pressure or voltage stimulus and to the duration of electrically induced AF in normotensive or hypertensive rats. Methods. AF was reproducibly induced by transesophageal atrial burst pacing in spontaneously hypertensive rats (SHR and Wistar-Kyoto rats (WKY. We did the burst pacing at high (20 V or low (5 V voltage. Results. Duration of AF did not correlate with systolic blood pressure (SBP and stimulus voltage in WKY. However, only in SHR, duration of AF with high stimulus voltage significantly correlated with SBP and was significantly longer in high than in low voltage stimulus. Discussion and Conclusion. Duration of AF is augmented by high voltage stimulus with higher blood pressure in SHR.

  14. Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines

    OpenAIRE

    Tourab, Wafa; Babouri, Abdesselam

    2015-01-01

    Background This work presents an experimental and modeling study of the electromagnetic environment in the vicinity of a high voltage substation located in eastern Algeria (Annaba city) specified with a very high population density. The effects of electromagnetic fields emanating from the coupled multi-lines high voltage power systems (MLHV) on the health of the workers and people living in proximity of substations has been analyzed. Methods Experimental Measurements for the Multi-lines power...

  15. Nanosecond pulsed electric fields (nsPEFs) low cost generator design using power MOSFET and Cockcroft-Walton multiplier circuit as high voltage DC source

    Science.gov (United States)

    Sulaeman, M. Y.; Widita, R.

    2014-09-01

    Purpose: Non-ionizing radiation therapy for cancer using pulsed electric field with high intensity field has become an interesting field new research topic. A new method using nanosecond pulsed electric fields (nsPEFs) offers a novel means to treat cancer. Not like the conventional electroporation, nsPEFs able to create nanopores in all membranes of the cell, including membrane in cell organelles, like mitochondria and nucleus. NsPEFs will promote cell death in several cell types, including cancer cell by apoptosis mechanism. NsPEFs will use pulse with intensity of electric field higher than conventional electroporation, between 20-100 kV/cm and with shorter duration of pulse than conventional electroporation. NsPEFs requires a generator to produce high voltage pulse and to achieve high intensity electric field with proper pulse width. However, manufacturing cost for creating generator that generates a high voltage with short duration for nsPEFs purposes is highly expensive. Hence, the aim of this research is to obtain the low cost generator design that is able to produce a high voltage pulse with nanosecond width and will be used for nsPEFs purposes. Method: Cockcroft-Walton multiplier circuit will boost the input of 220 volt AC into high voltage DC around 1500 volt and it will be combined by a series of power MOSFET as a fast switch to obtain a high voltage with nanosecond pulse width. The motivation using Cockcroft-Walton multiplier is to acquire a low-cost high voltage DC generator; it will use capacitors and diodes arranged like a step. Power MOSFET connected in series is used as voltage divider to share the high voltage in order not to damage them. Results: This design is expected to acquire a low-cost generator that can achieve the high voltage pulse in amount of -1.5 kV with falltime 3 ns and risetime 15 ns into a 50Ω load that will be used for nsPEFs purposes. Further detailed on the circuit design will be explained at presentation.

  16. Nanosecond pulsed electric fields (nsPEFs) low cost generator design using power MOSFET and Cockcroft-Walton multiplier circuit as high voltage DC source

    Energy Technology Data Exchange (ETDEWEB)

    Sulaeman, M. Y.; Widita, R. [Department of Physics, Nuclear Physics and Biophysics Research Division, Faculty of Mathematics and Natural Science, Institut Teknologi Bandung, Bandung (Indonesia)

    2014-09-30

    Purpose: Non-ionizing radiation therapy for cancer using pulsed electric field with high intensity field has become an interesting field new research topic. A new method using nanosecond pulsed electric fields (nsPEFs) offers a novel means to treat cancer. Not like the conventional electroporation, nsPEFs able to create nanopores in all membranes of the cell, including membrane in cell organelles, like mitochondria and nucleus. NsPEFs will promote cell death in several cell types, including cancer cell by apoptosis mechanism. NsPEFs will use pulse with intensity of electric field higher than conventional electroporation, between 20–100 kV/cm and with shorter duration of pulse than conventional electroporation. NsPEFs requires a generator to produce high voltage pulse and to achieve high intensity electric field with proper pulse width. However, manufacturing cost for creating generator that generates a high voltage with short duration for nsPEFs purposes is highly expensive. Hence, the aim of this research is to obtain the low cost generator design that is able to produce a high voltage pulse with nanosecond width and will be used for nsPEFs purposes. Method: Cockcroft-Walton multiplier circuit will boost the input of 220 volt AC into high voltage DC around 1500 volt and it will be combined by a series of power MOSFET as a fast switch to obtain a high voltage with nanosecond pulse width. The motivation using Cockcroft-Walton multiplier is to acquire a low-cost high voltage DC generator; it will use capacitors and diodes arranged like a step. Power MOSFET connected in series is used as voltage divider to share the high voltage in order not to damage them. Results: This design is expected to acquire a low-cost generator that can achieve the high voltage pulse in amount of −1.5 kV with falltime 3 ns and risetime 15 ns into a 50Ω load that will be used for nsPEFs purposes. Further detailed on the circuit design will be explained at presentation.

  17. High Voltage Seismic Generator

    Science.gov (United States)

    Bogacz, Adrian; Pala, Damian; Knafel, Marcin

    2015-04-01

    This contribution describes the preliminary result of annual cooperation of three student research groups from AGH UST in Krakow, Poland. The aim of this cooperation was to develop and construct a high voltage seismic wave generator. Constructed device uses a high-energy electrical discharge to generate seismic wave in ground. This type of device can be applied in several different methods of seismic measurement, but because of its limited power it is mainly dedicated for engineering geophysics. The source operates on a basic physical principles. The energy is stored in capacitor bank, which is charged by two stage low to high voltage converter. Stored energy is then released in very short time through high voltage thyristor in spark gap. The whole appliance is powered from li-ion battery and controlled by ATmega microcontroller. It is possible to construct larger and more powerful device. In this contribution the structure of device with technical specifications is resented. As a part of the investigation the prototype was built and series of experiments conducted. System parameter was measured, on this basis specification of elements for the final device were chosen. First stage of the project was successful. It was possible to efficiently generate seismic waves with constructed device. Then the field test was conducted. Spark gap wasplaced in shallowborehole(0.5 m) filled with salt water. Geophones were placed on the ground in straight line. The comparison of signal registered with hammer source and sparker source was made. The results of the test measurements are presented and discussed. Analysis of the collected data shows that characteristic of generated seismic signal is very promising, thus confirms possibility of practical application of the new high voltage generator. The biggest advantage of presented device after signal characteristics is its size which is 0.5 x 0.25 x 0.2 m and weight approximately 7 kg. This features with small li-ion battery makes

  18. 'Sabbath' electric plate burn: a ritual hazard.

    Science.gov (United States)

    Benmeir, P; Sagi, A; Rosenberg, L; Picard, E; Ben Yakar, Y

    1989-02-01

    This report describes the burns caused by an electric hot plate which is used by orthodox Jews for keeping food and liquids warm during the Sabbath (Saturday). An illustrative case is presented and the preventable aspects of this particular burn are discussed.

  19. Automatic System for the D.C. High Voltage Qualification of the Superconducting Electrical Circuits of the LHC Machine

    CERN Document Server

    Bozzini, D; Russenschuck, Stephan; Bednarek, M; Jurkiewicz, P; Kotarba, A; Ludwin, J; Olek, S

    2008-01-01

    A d.c. high voltage test system has been developed to verify automatically the insulation resistance of the powering circuits of the LHC. In the most complex case, up to 72 circuits share the same volume inside cryogenic lines. Each circuit can have an insulation fault versus any other circuit or versus ground. The system is able to connect up to 80 circuits and apply a voltage up to 2 kV D.C. The leakage current flowing through each circuit is measured within a range of 1 nA to 1.6 mA. The matrix of measurements allows characterizing the paths taken by the currents and locating weak points of the insulation between circuits. The system is composed of a D.C. voltage source and a data acquisition card. The card is able to measure with precision currents and voltages and to drive up to 5 high voltage switching modules offering 16 channels each. A LabVIEW application controls the system for an automatic and safe operation. This paper describes the hardware and software design, the testing methodology and the res...

  20. 高强脉冲电场与臭氧联用降解壳聚糖%Degradation of chitosan by high voltage pulsed electric field and ozone

    Institute of Scientific and Technical Information of China (English)

    罗文波; 唐超; 曾新安; 于淑娟

    2013-01-01

    The vigorous oxidation ability of ozone and the high energy input of pulsed electric field were utilized to degrade the macromolecular chitosan to oligochitosan. The degradation rate was up to 98. 5% after the combined treatment of high voltage pulsed electric field and ozone for 30 minutes in acetic acid homogeneous phase. Three experiment schemes of individual and combined treatments of high voltage pulsed electric field and ozone were designed the results showed that the efficiency of combined treatment was higher than that of single treatments, so the combination of high voltage pulsed electric field and ozone had high synergistic effect. By infrared spectrum analysis, the structure of degraded chitosan was not changed compared to the initial chitosan.%利用臭氧的强氧化性和电场的高能量降解大分子壳聚糖为壳寡糖.在乙酸均相体系中,高强脉冲电场与臭氧联用处理壳聚糖30min时,壳聚糖的降解率达到98.5%.设计了脉冲电场、臭氧单独处理和电场与臭氧联用处理3种实验方案,结果表明:电场与臭氧联用的处理效率要高于分别处理效率,电场与臭氧联用具有协同作用.经红外光谱分析,降解产物与原料壳聚糖结构基本一致.

  1. Brain hemorrhage after electrical burn injury: Case report and probable mechanism

    Science.gov (United States)

    Axayacalt, Gutierrez Aceves Guillermo; Alejandro, Ceja Espinosa; Marcos, Rios Alanis; Inocencio, Ruiz Flores Milton; Alfredo, Herrera Gonzalez Jose

    2016-01-01

    Background: High-voltage electric injury may induce lesion in different organs. In addition to the local tissue damage, electrical injuries may lead to neurological deficits, musculoskeletal damage, and cardiovascular injury. Severe vascular damage may occur making the blood vessels involved prone to thrombosis and spontaneous rupture. Case Description: Here, we present the case of a 39-year-old male who suffered an electrical burn with high tension wire causing intracranial bleeding. He presented with an electrical burn in the parietal area (entry zone) and the left forearm (exit zone). The head tomography scan revealed an intraparenchimatous bleeding in the left parietal area. In this case, the electric way was the scalp, cranial bone, blood vessels and brain, upper limb muscle, and skin. The damage was different according to the dielectric property in each tissue. The injury was in the scalp, cerebral blood vessel, skeletal muscle, and upper limb skin. The main damage was in brain’s blood vessels because of the dielectric and geometric features that lead to bleeding, high temperature, and gas delivering. Conclusion: This is a report of a patient with an electric brain injury that can be useful to elucidate the behavior of the high voltage electrical current flow into the nervous system. PMID:27904757

  2. Compact, Lightweight, High Voltage Propellant Isolators Project

    Data.gov (United States)

    National Aeronautics and Space Administration — TA&T, Inc. proposes an enabling fabrication process for high voltage isolators required in high power solar electric and nuclear electric propulsion (SEP and...

  3. Compact, Lightweight, High Voltage Propellant Isolators Project

    Data.gov (United States)

    National Aeronautics and Space Administration — TA&T, Inc. proposes an enabling fabrication process for high voltage isolators required in high power solar electric and nuclear electric propulsion (SEP and...

  4. High-voltage engineering and testing

    CERN Document Server

    Ryan, Hugh M

    2013-01-01

    This 3rd edition of High Voltage Engineering Testing describes strategic developments in the field and reflects on how they can best be managed. All the key components of high voltage and distribution systems are covered including electric power networks, UHV and HV. Distribution systems including HVDC and power electronic systems are also considered.

  5. Analysis of the Mechanisms Determining the Thermal and Electrical Properties of Epoxy Nanocomposites for High Voltage Applications

    NARCIS (Netherlands)

    Tsekmes, I.A.

    2016-01-01

    The addition of microsized fillers to polymers, in order to tailor their properties, has been extensively used in many industrial applications since the 1960s. The same approach applies to the field of electrical insulation. Epoxy resin is a widely used polymer in the electrical power sector, but it

  6. Analysis of the Mechanisms Determining the Thermal and Electrical Properties of Epoxy Nanocomposites for High Voltage Applications

    NARCIS (Netherlands)

    Tsekmes, I.A.

    2016-01-01

    The addition of microsized fillers to polymers, in order to tailor their properties, has been extensively used in many industrial applications since the 1960s. The same approach applies to the field of electrical insulation. Epoxy resin is a widely used polymer in the electrical power sector, but it

  7. Development of a Novel Bidirectional DC/DC Converter Topology with High Voltage Conversion Ratio for Electric Vehicles and DC-Microgrids

    Directory of Open Access Journals (Sweden)

    Ching-Ming Lai

    2016-05-01

    Full Text Available The main objective of this paper was to study a bidirectional direct current to direct current converter (BDC topology with a high voltage conversion ratio for electric vehicle (EV batteries connected to a dc-microgrid system. In this study, an unregulated level converter (ULC cascaded with a two-phase interleaved buck-boost charge-pump converter (IBCPC is introduced to achieve a high conversion ratio with a simpler control circuit. In discharge state, the topology acts as a two-stage voltage-doubler boost converter to achieve high step-up conversion ratio (48 V to 385 V. In charge state, the converter acts as two cascaded voltage-divider buck converters to achieve high voltage step-down conversion ratio (385 V to 48 V. The features, operation principles, steady-state analysis, simulation and experimental results are made to verify the performance of the studied novel BDC. Finally, a 500 W rating prototype system is constructed for verifying the validity of the operation principle. Experimental results show that highest efficiencies of 96% and 95% can be achieved, respectively, in charge and discharge states.

  8. INFLUENCE OF RARE-EARTH DOPING ON THE ELECTRICAL PROPERTIES OF HIGH VOLTAGE GRADIENT ZnO VARISTORS

    Directory of Open Access Journals (Sweden)

    LEI KE

    2013-03-01

    Full Text Available The influence of rare-earth doping on the electrical properties of ZnO varistors was investigated. In a lower doping region, the electrical properties were greatly improved with the increase of rare-earth contents. The highest voltage gradient value of 1968.0 V/mm was obtained with a rare-earth concentration of 0.06 mol. %. The microstructure of samples with different amounts of rare-earth oxides was examined and the notable decrease of grain size was identified as the origin for the increased voltage gradient. The doped rare-earth oxides dissolved at the grain boundaries and the excessive doping reduced the voltage across the single grain/grain boundary from 2.72 V to 0.91 V. The poor electrical properties in a higher doping region resulted from the degeneration of grain boundaries and the decrease of block density.

  9. INFLUENCE OF RARE-EARTH DOPING ON THE ELECTRICAL PROPERTIES OF HIGH VOLTAGE GRADIENT ZnO VARISTORS

    OpenAIRE

    2013-01-01

    The influence of rare-earth doping on the electrical properties of ZnO varistors was investigated. In a lower doping region, the electrical properties were greatly improved with the increase of rare-earth contents. The highest voltage gradient value of 1968.0 V/mm was obtained with a rare-earth concentration of 0.06 mol. %. The microstructure of samples with different amounts of rare-earth oxides was examined and the notable decrease of grain size was identified as the origin for the increase...

  10. Effects of high voltage electrical stimulation on the rate of pH decline, meat quality and color stability in chilled beef carcasses

    Institute of Scientific and Technical Information of China (English)

    Ehsan Gharib Mombeni; Manoochehr Gharib Mombeini; Lucas Chaves Figueiredo; Debora Testoni Dias

    2013-01-01

    Objective:To determine the effects of high voltage electrical stimulation (HVES, 800 Voltage) on rapid decreases in pH values and improvements in meat quality. Methods:A total of 50 beef carcasses were applied, divided into two groups, one as a control and another for HVES. Meat quality was evaluated based on M. longissimus dorsi by examining pH and temperature levels at 1, 2, 5, 10 and 24 h, while color stability was examined seven days after slaughter. Results:HVES decreased the pH values of the meat and accelerated rigor mortis (P Conclusion:the HVES had positive effects on meat quality and color stability, in contrast to undesirable consumer preferences.

  11. New Approach for High-Voltage Electrical Double-Layer Capacitors Using Vertical Graphene Nanowalls with and without Nitrogen Doping.

    Science.gov (United States)

    Chi, Yu-Wen; Hu, Chi-Chang; Shen, Hsiao-Hsuan; Huang, Kun-Ping

    2016-09-14

    Integrating various devices to achieve high-performance energy storage systems to satisfy various demands in modern societies become more and more important. Electrical double-layer capacitors (EDLCs), one kind of the electrochemical capacitors, generally provide the merits of high charge-discharge rates, extremely long cycle life, and high efficiency in electricity capture/storage, leading to a desirable device of electricity management from portable electronics to hybrid vehicles or even smart grid application. However, the low cell voltage (2.5-2.7 V in organic liquid electrolytes) of EDLCs lacks the direct combination of Li-ion batteries (LIBs) and EDLCs for creating new functions in future applications without considering the issue of a relatively low energy density. Here we propose a guideline, "choosing a matching pair of electrode materials and electrolytes", to effectively extend the cell voltage of EDLCs according to three general strategies. Based on the new strategy proposed in this work, materials with an inert surface enable to tolerate a wider potential window in commercially available organic electrolytes in comparison with activated carbons (ACs). The binder-free, vertically grown graphene nanowalls (GNW) and nitrogen-doped GNW (NGNW) electrodes respectively provide good examples for extending the upper potential limit of a positive electrode of EDLCs from 0.1 to 1.5 V (vs Ag/AgNO3) as well as the lower potential limit of a negative electrode of EDLCs from -2.0 V to ca. -2.5 V in 1 M TEABF4/PC (propylene carbonate) compared to ACs. This newly designed asymmetric EDLC exhibits a cell voltage of 4 V, specific energy of 52 Wh kg(-1) (ca. a device energy density of 13 Wh kg(-1)), and specific power of 8 kW kg(-1) and ca. 100% retention after 10,000 cycles charge-discharge, reducing the series number of EDLCs to enlarge the module voltage and opening the possibility for directly combining EDLCs and LIBs in advanced applications.

  12. High- voltage Pulsed Electric Field Sterilization Equipment and Flow Control%高压脉冲电场灭菌设备及其流量控制

    Institute of Scientific and Technical Information of China (English)

    林荣华; 李伟光

    2012-01-01

    In order to optimize the sterilization effect of high-voltage pulsed electric field sterilization equipment, this paper analyzes its function according the tactors of the enfluence on the system, designs the overall structure and PLC-based flow control system by the way of frequency control of motor speed, describes the structure and principle of high-voltage pulse generator and the theory and realization of the flow control based on frequency control as well as the realization of communication between inverters and PLC with RS-485. The result shows that the equipment is able to control and adjust key process parameters well, comtro the flow by a simple and reliable way, and achieve high effective and fast sterilization.%为优化高压脉冲电场灭菌设备的灭菌效果,根据其影响因素进行了系统功能需求分析,设计了设备的总体架构,采用变频调速的方法,设计了基于PLC的流量控制系统.简述了高压脉冲发生器的结构及原理,重点介绍了基于变频调速的流量控制原理与实现,变频器与PLC的RS - 485通信的实现.实验表明,设备实现了关键工艺参数可调可控,运行效果良好,简单可靠地实现了流量的控制,实现了快速高效灭菌.

  13. Burns

    Science.gov (United States)

    A burn is damage to your body's tissues caused by heat, chemicals, electricity, sunlight, or radiation. Scalds from hot ... and gases are the most common causes of burns. Another kind is an inhalation injury, caused by ...

  14. High voltage pulse generator

    Science.gov (United States)

    Fasching, George E.

    1977-03-08

    An improved high-voltage pulse generator has been provided which is especially useful in ultrasonic testing of rock core samples. An N number of capacitors are charged in parallel to V volts and at the proper instance are coupled in series to produce a high-voltage pulse of N times V volts. Rapid switching of the capacitors from the paralleled charging configuration to the series discharging configuration is accomplished by using silicon-controlled rectifiers which are chain self-triggered following the initial triggering of a first one of the rectifiers connected between the first and second of the plurality of charging capacitors. A timing and triggering circuit is provided to properly synchronize triggering pulses to the first SCR at a time when the charging voltage is not being applied to the parallel-connected charging capacitors. Alternate circuits are provided for controlling the application of the charging voltage from a charging circuit to be applied to the parallel capacitors which provides a selection of at least two different intervals in which the charging voltage is turned "off" to allow the SCR's connecting the capacitors in series to turn "off" before recharging begins. The high-voltage pulse-generating circuit including the N capacitors and corresponding SCR's which connect the capacitors in series when triggered "on" further includes diodes and series-connected inductors between the parallel-connected charging capacitors which allow sufficiently fast charging of the capacitors for a high pulse repetition rate and yet allow considerable control of the decay time of the high-voltage pulses from the pulse-generating circuit.

  15. High voltage engineering fundamentals

    CERN Document Server

    Kuffel, E; Hammond, P

    1984-01-01

    Provides a comprehensive treatment of high voltage engineering fundamentals at the introductory and intermediate levels. It covers: techniques used for generation and measurement of high direct, alternating and surge voltages for general application in industrial testing and selected special examples found in basic research; analytical and numerical calculation of electrostatic fields in simple practical insulation system; basic ionisation and decay processes in gases and breakdown mechanisms of gaseous, liquid and solid dielectrics; partial discharges and modern discharge detectors; and over

  16. High-voltage picoamperemeter

    Energy Technology Data Exchange (ETDEWEB)

    Bugl, Andrea; Ball, Markus; Boehmer, Michael; Doerheim, Sverre; Hoenle, Andreas; Konorov, Igor [Technische Universitaet Muenchen, Garching (Germany); Ketzer, Bernhard [Technische Universitaet Muenchen, Garching (Germany); Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany)

    2014-07-01

    Current measurements in the nano- and picoampere region on high voltage are an important tool to understand charge transfer processes in micropattern gas detectors like the Gas Electron Multiplier (GEM). They are currently used to e.g. optimize the field configuration in a multi-GEM stack to be used in the ALICE TPC after the upgrade of the experiment during the 2nd long shutdown of the LHC. Devices which allow measurements down to 1pA at high voltage up to 6 kV have been developed at TU Muenchen. They are based on analog current measurements via the voltage drop over a switchable shunt. A microcontroller collects 128 digital ADC values and calculates their mean and standard deviation. This information is sent with a wireless transmitting unit to a computer and stored in a root file. A nearly unlimited number of devices can be operated simultaneously and read out by a single receiver. The results can also be displayed on a LCD directly at the device. Battery operation and the wireless readout are important to protect the user from any contact to high voltage. The principle of the device is explained, and systematic studies of their properties are shown.

  17. 高压脉冲电场灭菌方法研究概况%Research on the High-voltage Pulsed Electric Field Sterilization Method

    Institute of Scientific and Technical Information of China (English)

    陈新梅; 李莹; 陈新华

    2014-01-01

    The high-voltage pulsed electric field (PEF) sterilization has significant advantages such as a short process-ing time,low energy consumption,small temperature rise,high sterilization rate and not affecting the effective components of drugs,and so on. Based on the review of the mechanism of PEF sterilization,sterilization devices and the possible influ-encing factors,and the comparison of other sterilization methods,the evaluation of the PEF sterilization method was made and the existing problems and commercial prospects in the fields of food and pharmaceuticals were discussed.%高压脉冲电场灭菌具有处理时间短、耗能低、升温小、灭菌率高、不影响药物的有效成分等显著优点,本文通过对高压脉冲电场灭菌作用机理、灭菌装置、可能的影响因素总结及与其他灭菌方式的比较,对高压脉冲电场灭菌方式进行评价,并探讨其现存问题及在食品、药品领域的应用前景。

  18. Recycling ``in situ`` of dielectric oil of electric transformer of medium and high voltage; Reciclaje ``in situ`` y ``en carga`` del aceite dielectrico de los transformadores electricos de media y alta tension

    Energy Technology Data Exchange (ETDEWEB)

    Solis, A.

    1997-06-01

    The author describes the process followed by the company to control the quality of every type of oil from electric transformer of medium and high voltage polluted because of its use. The pollutants contained in the dielectric liquid are eliminated or minimize through the following treatments: conditioning-reconditioning-regeneration. (Author) 6 refs.

  19. A randomized, double-blind, sham-controlled study of static electric field therapy by high voltage alternating current for active rheumatoid arthritis.

    Science.gov (United States)

    Naito, Yuji; Yamaguchi, Shinnichi; Mori, Yasuhiro; Nakajima, Kouji; Hashimoto, Sanshiro; Tomaru, Masakazu; Satoh, Yoshihiko; Hitomi, Yuji; Karita, Masakazu; Hiwatashi, Tomoaki; Kawahito, Yutaka; Yoshikawa, Toshikazu

    2013-07-01

    Static electric field therapy by high voltage alternating current (EF-HVAC) is a traditional complementary Japanese medicine used for headache, shoulder stiffness, chronic constipation and insomnia. Open-label studies and clinical experience in Japan have suggested that this electric field therapy is safe and effective in treating chronic arthritis. We evaluated the efficacy of EF-HVAC therapy in a randomized, double-blinded, sham-controlled trial in patients with active rheumatoid arthritis (RA) in community-based general physician centers. Thirty patients fulfilling American College of Rheumatology (ACR) criteria for RA were treated with EF-HVAC therapy with the LEGACIS PLUS System (COCOROCA Corp., Tokyo, Japan) or sham therapy for 12 weeks and followed for 4 weeks without treatment. The disease activity score 28 (DAS28-CRP), visual analogue scale for pain (VAS), modified health assessment questionnaire (MHAQ), and inflammatory parameters were used as the outcome variable. Twenty four patients (n = 12 in each group) were analyzed by a per protocol analysis. Although a significant reduction in DAS28-CRP was observed in EF-HVAC group at 8 and 12 weeks compared to before treatment, there were no significant differences in DAS28-CRP scores during treatment between two groups. The scale of VAS was also significantly decreased by the treatment with EF-HVAC compared to before treatment, in addition, the scale of VAS in EF-HVAC group was significantly lower than sham group at 8 and 12 weeks. Changes in another parameters including MHAQ were not significant between before and after treatment, or by all comparative study between two groups. There were no adverse events related the treatment. In conclusion, the EF-HVAC therapy has a beneficial effect on the improvement to subjective pain of RA.

  20. Development of High - voltage Pulse - transmission Electric Cable for Plasma Drill%等离子体钻机高压脉冲传输电缆的研制

    Institute of Scientific and Technical Information of China (English)

    季念迎; 裴彦良; 闫克平; 刘晨光; 章志成

    2012-01-01

    设计了等离子钻机高压脉冲传输电缆的结构,讨论了高压绝缘层的设计及材料选择.在此基础上,开展了高压脉冲传输电缆的绝缘阻抗和波阻抗测试实验.实验测试结果表明,所研制的传输电缆具有较高的绝缘性能和较小的波阻抗,可基本满足等离子体钻机的需要.%The structure of the high - voltage pulse - transmission electric cable was designed. The design of high - voltage insulation layer and the insulation material were discussed. Based on what mentioned above, the insulating resistance and the wave resistance tests of the high - voltage pulse - transmission electric cable were carried out. The test results show that the high - voltage pulse - transmission electric cable has good insulating property and little wave resistance, which meets the challenges of the plasma drill.

  1. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  2. Effect of high-voltage electrical stimulation on the albumin and histamine serum concentrations, edema, and pain in acute joint inflammation of rats

    Directory of Open Access Journals (Sweden)

    Maria C. Sandoval

    2015-04-01

    Full Text Available BACKGROUND: The mechanism by which high-voltage electrical stimulation (HVPC acts on edema reduction is unknown. OBJECTIVE: To assess the effect of HVPC with negative polarity (- applied to the ankle of rats with acute joint inflammation. METHOD: Sixty-four rats were divided into four groups (n=16: inflamed+HVPC(-, 0.03 mL application of ι-carrageenan (3% to the tibiotarsal joint plus HVPC(-; inflamed+HVPC placebo, carrageenan application and HVPC placebo; normal+HVPC(-, HVPC application(-; and normal control, no intervention. The HVPC(- 100 Hz at a submotor level was applied daily for 45 min on three consecutive days. The variables were pain, hind-foot volume, and serum histamine and albumin assessed before and during the 48 hours following inflammation. The variables were compared using the t test, one-way ANOVA, nested ANOVA for repeated measures, and the post hoc Bonferroni test. Analysis of covariance was applied to adjust the effects of HVPC(- by measurements of pain, inflammation, albumin, and histamine at 24 h, and the final weight was compared to the other groups. The significance level was set at p0.05. Albumin was reduced in the groups that received the intervention, but there was no differences between them. There was only a 24 hour increase in histamine with the normal+HVPC(- (p=0.0001 and inflamed+HVPC placebo groups (p=0.01 compared to the normal control group. CONCLUSIONS: The results of the present study suggest that HVPC(- with the parameters employed did not reduce pain or edema and did not change serum albumin or histamine levels,, which indicates the inability of this resource to have a positive effect when treating treat acute joint inflammation.

  3. High-voltage test and measuring techniques

    CERN Document Server

    Hauschild, Wolfgang

    2014-01-01

    It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  4. MRI study of acute high-voltage electric injury in forearm muscle%前臂肌群急性高压电击伤的MRI研究

    Institute of Scientific and Technical Information of China (English)

    舒锦尔; 盛三兰; 卢金花; 蒋春景; 仇旭光; 李惠民

    2001-01-01

    目的 分析前臂肌群急性高压电击伤的MRI表现,并探讨其临床意义。方法 9例 17只急性高压电击伤的前臂均于72 h内行术前MRI检查,并作病理对照。7例14只前臂并行增强扫描。结果 9例 17只前臂均于MRI检查后立即行筋膜切开扩创术。单纯扩创者6例 11只前臂,MRI表现主要为前群肌肉的损伤,范围较小,呈等T1、长T2信号;后群肌肉损伤较分散,无一定规律,损伤程度较轻,病灶近端增强后和T2WI均示边界锐利,呈刀尖样改变;其中4例8只做了增强扫描,见显著异常强化(Ⅰ型信号),术中电灼刺激相应肌肉有收缩,但较正常减弱,病理见不同程度坏死;在增强4例8只前臂中,有1个移行区者6只,有2个移行区者2只,各移行区边界均较清楚。扩创后截肢者3例 6只前臂,MRI表现为弥漫性前后群肌的损伤,呈混合信号,前臂近端以Ⅰ型信号为主,远端大片呈等T1、长T2或短T2信号,且无明显异常强化(Ⅱ、Ⅲ型信号),术中电灼刺激相应肌肉,未见明确收缩,病理提示几乎完全坏死。所有截肢前臂均有2个移行区,边界不清,第2移行区均呈花边状强化。结论 前臂肌群急性高压电击伤MRI表现为3种信号模式,与病理有明确对应关系,有助于临床处理及预后判断。%Objective To investigate the features of MR imaging of acute high-voltage electric injury in forearm muscle. Methods Nine patients (17 forearms, 8 males and 1 female, 15~36 years of age) with clinically and pathological proved acute high-voltage electric injury were studied on MRI retrospectively. MRI studies were obtained within 72 hours on Siemens 1.0 T MR scanner. 2 forearms were examined with body coil, and 15 with head coil. The severe area was placed as near as possible to the isocenter in the magnet and was used as the center of the MR imaging acquisition. Spin-echo T1 weighted images

  5. An unusual electrical burn caused by alkaline batteries

    Directory of Open Access Journals (Sweden)

    Tyng-Luen Roan

    2015-02-01

    Full Text Available Electrical burns caused by low-voltage batteries are rarely reported. We recently encountered a male patient who suffered from a superficial second-degree burn over his left elbow and back. The total body surface area of the burn was estimated to be 6%. After interviewing the patient, the cause was suspected to be related to the explosion of a music player on the left-side of his waist, carried on his belt while he was painting a bathroom wall. Elevated creatine kinase levels and hematuria indicated rhabdomyolysis and suggested an electrical burn. Initial treatment was done in the burn intensive care unit with fluid challenge and wound care. The creatine kinase level decreased gradually and the hematuria was gone after 4 days in the intensive care unit. He was then transferred to the general ward for further wound management and discharged from our burn center after a total of 11 days without surgical intervention.

  6. High voltage load resistor array

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, Monty Ray [Smithfield, VA

    2005-01-18

    A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

  7. Clinical management of electrical burns in the developing world: a case of electrical burn injury left untreated leading to amputation.

    Science.gov (United States)

    Choong, Marcus; Chy, Delia; Guevarra, Jerric R; Ross, Allen G

    2017-02-15

    We discuss the case of a 26-year-old male patient from Northern Samar, the Philippines who was left without essential health services after the amputation of all four limbs following a high voltage (20 000 volts) injury in Metro Manila in 2011. Local health services in the developing world are faced with enormous challenges in providing first-line care for burn patients. The cost of maintaining a burn unit, finding suitable qualified staff, and appropriate referral mechanisms are only some of the challenges faced. Once a patient is discharged from hospital they face more obstacles in obtaining artificial limbs, physiotherapy and access to mental health services. Disability pensions are non-existent thus patients place a considerable lifelong burden on their families. 2017 BMJ Publishing Group Ltd.

  8. High-tension Electrical Burns: Report of Two Cases

    OpenAIRE

    Abbas, A.D.; Dabkana, T.M.; Tahir, C.; Naaya, H.U.

    2009-01-01

    High-tension electrical burns are a rare but devastating form of injury. The objective of this case report is to bring to the fore the severity of this rare form of injury and highlight the benefits of active surgical management of such a condition. We report the cases of two patients who were managed for high-tension electrical burns and highlight the main features of their presentation and management. Both patients needed urgent resuscitation and subsequent multiple amputations and disartic...

  9. Study of High Voltage AC Underground Cable Systems

    DEFF Research Database (Denmark)

    da Silva, Filipe Miguel Faria; Bak, Claus Leth; Wiechowski, Wojciech T.

    2010-01-01

    High-Voltage cables are starting to be more often used to transmit electric energy at high-voltage levels, introducing in the electric grid phenomena that are uncommon when using Overhead Lines. Under the phenomena worthy of special attention are those related with the cable energisation and deen...

  10. 高压脉冲电场对微生物的灭活作用研究进展%Research Progress in the Effect of High-voltage Pulsed Electric Field on Microorganism Inactivation

    Institute of Scientific and Technical Information of China (English)

    陈新梅; 薛文静; 赵元

    2016-01-01

    Objective:To review the inactivation effect of high-voltage pulsed electric field on microorganism to provid theoretical basis for the further research and sterilization application of high-voltage pulsed electric field. Methods:The combination of high-volt-age pulse electric field, microbiology and pulse electric field as the keywords, the research results of high-voltage pulsed electric field on microbial inactivation in PubMed, CNKI, VIP Chinese journal full text database and Wanfang database during 2010 and 2015 were retrieved, summarized and reviewed. Results:As a non-thermal sterilization technology, high-voltage pulsed electric field not only had the characteristics of short sterilization time, narrow increasing extent of temperature and low energy consumption, but also could keep the original flavor of food. Conclusion:With the development of related technology, high-voltage pulsed electric field is expected to re-alize industrialization.%目的::综述高压脉冲电场对微生物的灭活作用,为进一步研究和应用高压脉冲电场灭菌提供理论基础。方法:以“高压脉冲电场”、“微生物”、“Pulse Electric Field”等组合为关键词,检索2010~2015年PubMed、中国知网、维普中文期刊全文数据库、万方数据库中有关高压脉冲电场对微生物的灭活作用的研究成果,进行总结和综述。结果:高压脉冲电场作为一种非热灭菌技术,不仅具有灭菌时间短、升温幅度小、耗能少的特点,还能保持食品原有风味不变。结论:随着相关技术的发展,高压脉冲电场有望实现产业化。

  11. Long-living plasmoids generation by high-voltage discharge through thin conducting layers

    CERN Document Server

    Pirozerski, A L

    2006-01-01

    A new type of pulse high voltage electric discharge through a thin conducting layer on the surface of glass plate has been investigated. The afterglow plasma of this discharge forms quasi-spherical object with a lifetime about 0.2-0.3 s. Electric properties of the objects were studied by electric probe method. Measurements of plasma radiation spectra kinetics at visible and near ultraviolet spectral ranges have been carried out. Comparative analysis of the physical properties of the plasmoids appearing in this discharges and of ones generated via thin metal wires burning is given. Possible mechanism of the plasma metastability are discussed.

  12. Development of a Remote Insulation Test Device for High-Voltage Electrical Motors%一种远程高压电机绝缘测试装置的开发研究

    Institute of Scientific and Technical Information of China (English)

    何锁侠; 佟洪明; 肖骥; 李开寒

    2014-01-01

    介绍了一种远程高压电机绝缘测试装置。根据系统需求,独自研发了一种加入了RS-485通信模块和控制模块的新一代电子式电阻表。基于西门子S7-200型PLC对高压电机绝缘监测设备、高压继电器、机械抓进行控制。建立了触摸屏、PLC、绝缘检测仪之间的通讯,实现了高压电机绝缘的远程测量功能。通过运用本装置,提高了高压电机绝缘检测的自动化水平,降低了设备维修频率,并保障了工人的人身安全。%A remote insulation test device for high -voltage electrical motors is introduced. To meet system requirement, a new -generation electronic insulation tester incorporating RS -485 communication module and control module was independently developed. Based on Siemens S7-200 PLC the system can control high-voltage motor insulation monitoring devices, high voltage relays and mechanical grips. Communication between the touch screen, PLC and insulation tester was established, realizing remote insulation measurement for high voltage motors. The device improves the automation level of high-voltage motor insulation test, reduces the frequency of equipment maintenance and ensures personal safety.

  13. 高压脉冲电参数对果蔬介电特性的影响机理分析%Influence Mechanism of High-voltage Pulsed Electric Parameters on Dielectric Properties of Fruits and Vegetables

    Institute of Scientific and Technical Information of China (English)

    马飞宇; 郭玉明

    2013-01-01

    The high voltage pulse electric field pretreatment can improve the freeze-drying rate of fruits and vegetables and reduce energy consumption .But when researching fruit and vegetable dielectric property about the changes of on -line monitoring freeze-dried moisture content ,high-voltage pulsed electric field should be considered the influence of electri-cal parameter on dielectric properties of fruit and vegetable .In the cellular level , high-voltage pulsed electric fields effects fruits and vegetables , analyzing the influence of electric parameters on dielectric properties of fruit and vegetable . For equivalent circuit model of fruits and vegetables biological tissue , electrical parameters influence on dielectric proper-ties of fruit and vegetable , such as fruit and vegetable equivalent capacitance and equivalent impedance , which were summarized and analyzed about mechanism to provide a reference on high voltage pulse electric field pretreatment fruit and vegetable processing parameters optimization .%高压脉冲电场预处理果蔬可以提高果蔬冻干速率、降低能耗。但研究运用果蔬介电特性在线监测冻干水分变化时,需要考虑高压脉冲电场电参数对果蔬介电特性的影响。为此,针对高压脉冲电场作用果蔬细胞层面,分析了电参数对果蔬介电特性的影响,对果蔬生物组织等效电路模型和电参数对果蔬等效电容、等效阻抗等介电特性的影响等方面进行了综述分析及机理分析,为高压脉冲电场预处理果蔬工艺参数优化提供了参考。

  14. Factors affecting mortality among victims of electrical burns.

    Science.gov (United States)

    Tiryaki, Çağrı; Haksal, Mustafa Celalettin; Yazıcıoğlu, Murat Burç; Çiftçi, Ali; Esen, Osman; Turgut, Hamdi Taner; Yıldırım, Abdullah; Güven, Murat

    2017-05-01

    The aim of this study was to determine the factors affecting mortality rate among patients with an electrical burn. A total of 115 patients admitted to the emergency department and hospitalized in the Burn Treatment Center or Intensive Care Unit (ICU) due to the electrical burn, were included in the study. A total of 115 patients (4 female and 111 male) with a mean age of 32.88±12.87 years were included in the study. The mean hospitalization period was 25.03±20.50 days, and the mean total body surface area burned (% TBSA) was 22.83±15.54%. Among those patients, 9 (8.5%) expired, and the remaining 106 were discharged after treatment. In a logistic regression analysis, TBSA >20% (p=0.02, OR: 11.7, CI: 1.38-99.16); ICU requirement (p=0.005, OR: 1.28, CI: 1.08-1.58); erythrocyte transfusion requirement (p=0.02, OR: 12.48, CI: 1.44-107.83); fresh frozen plasma (FFP) requirement (p=0.03, OR: 10.23, CI: 1.18-88.17); albumin requirement (p=0.02, OR: 12.60, CI: 1.44-109.85); admission serum albumin level patients with electrical burns. In clinical practice, defining a mortality risk analyzer using these factors may be helpful in the management of patients with electrical burns. Additional, more comprehensive studies are required to define the risk factors for mortality and long-term morbidities in patients with electrical burns.

  15. Electrical engineering. High and very high voltage substations. Metal envelope insulated substations; Genie electrique. Postes a haute et tres haute tensions. Poste sous enveloppe metallique (PSEM)

    Energy Technology Data Exchange (ETDEWEB)

    Taillebois, J.P. [Centre National d' Expertise Reseaux du Gestionnaire du Reseau de Transport d' Electricite (France)

    2001-02-01

    Metal envelope substations with pressurized sulfur hexafluoride (SF{sub 6}) allow to considerably reduce the insulation distances between the different components of high and very-high voltage substations (phases, ground, switches and circuit breakers), thus leading to compact power systems with reduced dimensions. This article presents the technical characteristics of metal envelope substations: design parameters and dimensioning, specific constraints, safety, technological solutions, characteristic values, diagnosis and monitoring methods, use of metal envelope substations in power distribution systems, perspectives of evolution. (J.S.)

  16. 红外辐射测温技术在煤矿高压电器检测中的应用%Infrared radiation thermometry techniques in the coal high voltage electrical detection

    Institute of Scientific and Technical Information of China (English)

    王兴举; 黄宗建; 李进曌

    2014-01-01

    Infraredradiation thermometry techniques have real-time,convenient and non-destructive,which is widely used in electrical products,temperature detection,especially in high-voltage electrical equipment due to coal mining complex run construction environment,conventional means is difficult to accurately measure the temperature changes,and infrared radiation thermometry can quickly and accurately measure high voltage electrical coal mines.This article from the infrared radiation thermometry in the coal high voltage electrical temperature measurement standpoint,focusing on the formation mechanism of the infrared radiation thermometry,testing methods and testing techniques to note,as the actual production process to provide a reliable theoretical basis.%红外辐射测温技术具备了实时、便捷以及非破坏性等特点,广泛用于电器产品温度的检测中,特别是煤矿高压电器设备由于复杂的运行施工环境,常规手段很难准确的测量温度的变化,而红外辐射测温能够迅速准确的对煤矿高压电器进行测量。本文主要从红外辐射测温技术在煤矿高压电器温度的测量方面出发,重点研究了红外辐射测温的形成机理、测试手段以及需要注意的测试技巧,为生产实际过程中提供一个可靠的理论依据。

  17. Modular High Voltage Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    Newell, Matthew R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-18

    The goal of this project is to develop a modular high voltage power supply that will meet the needs of safeguards applications and provide a modular plug and play supply for use with standard electronic racks.

  18. High-voltage test and measuring techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hauschild, Wolfgang; Lemke, Eberhard

    2014-04-01

    Reflects the unit of both HV testing and measuring technique. Intended as an ''application guide'' for the relevant IEC standards. Refers also to future trends in HV testing and measuring technique. With numerous illustrations. It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  19. Isolated Fast High-Voltage Switching Circuit

    Science.gov (United States)

    Rizzi, Anthony

    1992-01-01

    Electrically isolated switching circuit supplies pulses at potentials up to 6.5 kV and currents up to 6.5 A, lasting as long as few microseconds. Turn-on time about 40 ns; turn-off time about 3 microseconds. Electrically isolated from control circuitry by means of fiber-optic signal coupling and isolated power supply. Electrical isolation protects both technician and equipment. This and similar circuits useful in such industrial and scientific applications as high-voltage, high-frequency test equipment; electrostatic-discharge test equipment; plasma-laboratory instrumentation; spark chambers; and electromagnetic-interference test equipment.

  20. Comparative studies on extraction of laminarin by high voltage pulsed electric fields and traditional method%高压脉冲电场和传统热水法提取海带多糖的比较研究

    Institute of Scientific and Technical Information of China (English)

    刘航; 冯立强; 刘兴江

    2016-01-01

    Orthogonal tests are carried out to determine optimal laminarin extraction technologies by the high voltage pulsed electric fields and the traditional hot water method.The mechanism of the high voltage pulsed electric fields is preliminarily discussed.The optimal conditions of traditional method are:1∶50 of material-liquid ratio,60 ℃ of extraction temperature and 40 minutes of extraction time.The optimal conditions of high voltage pulsed electric fields are:1 ∶ 30 of material-liquid ratio,20 minutes of pulse time,10 kV of electric field intensity and 50 Hz of pulse frequency.Compared with traditional hot water extraction method,the extraction time is shortened by 50% and the extraction ratio is increased by 45% for high voltage pulsed electric field method.%利用正交试验确定了高压电脉冲电场和传统热水法提取海带多糖的方法的最佳工艺,并对2种工艺进行了比较,初步探讨高压脉冲的作用机理.结果表明,传统热水法提取海带多糖的最佳工艺为:海带粉与去离子水的料液比为1∶50,提取温度为60℃,提取时间为40 min.高压脉冲电场的最佳工艺为:海带粉与去离子水的料液比为1∶30,脉冲时间为20 min,脉冲电压为10 kV,脉冲频率为50 Hz.提取时间仅为传统热水法时间的1/2,海带多糖提取率比传统热水法提高45%.

  1. High Voltage Design Guide. Volume V. Spacecraft

    Science.gov (United States)

    1983-01-01

    connector are soldered, with the possible exception of very high voltage points. Even then rudimentary connectors such as that shown In figura 13 ar used...addition, large stresses will be imposed on the struc- tural (high resistance) member. This conductor movement will flex and stretch the conductors, placing...materials used for airplane systems provided they meet the electrical, chemical, and mechanical characteristic requirements imposed by the design

  2. Experimental validation of prototype high voltage bushing

    Science.gov (United States)

    Shah, Sejal; Tyagi, H.; Sharma, D.; Parmar, D.; M. N., Vishnudev; Joshi, K.; Patel, K.; Yadav, A.; Patel, R.; Bandyopadhyay, M.; Rotti, C.; Chakraborty, A.

    2017-08-01

    Prototype High voltage bushing (PHVB) is a scaled down configuration of DNB High Voltage Bushing (HVB) of ITER. It is designed for operation at 50 kV DC to ensure operational performance and thereby confirming the design configuration of DNB HVB. Two concentric insulators viz. Ceramic and Fiber reinforced polymer (FRP) rings are used as double layered vacuum boundary for 50 kV isolation between grounded and high voltage flanges. Stress shields are designed for smooth electric field distribution. During ceramic to Kovar brazing, spilling cannot be controlled which may lead to high localized electrostatic stress. To understand spilling phenomenon and precise stress calculation, quantitative analysis was performed using Scanning Electron Microscopy (SEM) of brazed sample and similar configuration modeled while performing the Finite Element (FE) analysis. FE analysis of PHVB is performed to find out electrical stresses on different areas of PHVB and are maintained similar to DNB HV Bushing. With this configuration, the experiment is performed considering ITER like vacuum and electrical parameters. Initial HV test is performed by temporary vacuum sealing arrangements using gaskets/O-rings at both ends in order to achieve desired vacuum and keep the system maintainable. During validation test, 50 kV voltage withstand is performed for one hour. Voltage withstand test for 60 kV DC (20% higher rated voltage) have also been performed without any breakdown. Successful operation of PHVB confirms the design of DNB HV Bushing. In this paper, configuration of PHVB with experimental validation data is presented.

  3. [Electrical flash burns, about 33 cases. A 10-year retrospective study. Epidemiology, treatment and prevention].

    Science.gov (United States)

    Carloni, R; Pechevy, L; Quignon, R; Yassine, A-H; Forme, N; Zakine, G

    2015-04-01

    The electric flash burns are a common cause of accident at workplace, especially among electricians. The aim of this study is to determine the parts of the body most often burned by the flash, to define the usual course and finally to give some simple rules of care and prevention. This is a retrospective, observational and descriptive study including all patients treated at the University Hospital of Tours for electrical flash burns between 1 January 2003 and 01 January 2013. A collection of medical and socio-economic data was achieved. We present 3 cases of patients hospitalized in our department. Thirty-three patients were included. In our series, all hospitalized patients were men. The average age was 43.2years (range 18 to 82years). In 81% of cases, the burn was due to a low voltage source, in 19% of cases to a high voltage source. It was an accident at workplace for 71% of patients, of whom 67% were electricians. The average total burned area was 9,52% (from 1.5% to 24%). The main locations included the face (86%), upper limbs (86%) and hands (86%). Medical treatment has healed 95% of patients. A surgical procedure was required in 5% of cases. A post-traumatic stress was found in 41% of patients. Outpatient treatment was performed in 36% of cases. Flash burns remain a common cause of hospitalization. Screening for hearing and eye disorders, a post-traumatic stress, as well as the prescription of early physiotherapy for burned hands are important components of their management. Following simple rules of prevention would limit their morbidity. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  4. Design of sewage treatment system based on high-voltage pulsed electric field technology%基于高压脉冲电场技术的污水处理系统研究设计

    Institute of Scientific and Technical Information of China (English)

    李唐; 王亚伟; 赵振良; 尤丽华

    2013-01-01

    针对污水处理厂剩余污泥含水率高,达到70%-80%,不利于进一步处理的问题,根据污水成分及其处理工艺特点,提出了一种基于高压脉冲电场技术的污水处理的方法.本文从理论上系统地阐述了高压脉冲电场处理装置的研制,设计了低成本高压脉冲电源,最高电压10 kV,最大电流50A,并且能方便的调节电场参数.%Contrary to the problem that the high moisture content of the excess sludge of the sewage treatment plant, up to 70% to 80% , the paper proposed a sewage treatment method based on the high-voltage pulse electric field (HPEF) technology, according to the composition of sewage and the feature of its treatment technology.The paper systematically expounded of how to design a pulsed electric field theoretically,and design a low-cost high-voltage pulse power supply with the peak impulse voltage 10 kV and impulse current to 50 A, which also can easily adjust the electric field parameters.

  5. 30 CFR 75.511 - Low-, medium-, or high-voltage distribution circuits and equipment; repair.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Low-, medium-, or high-voltage distribution... Electrical Equipment-General § 75.511 Low-, medium-, or high-voltage distribution circuits and equipment; repair. No electrical work shall be performed on low-, medium-, or high-voltage distribution circuits or...

  6. System for instrumenting and manipulating apparatuses in high voltage

    Science.gov (United States)

    Jordan, Kevin

    2016-06-07

    A system for energizing, operating and manipulating apparatuses in high voltage systems. The system uses a dielectric gas such as SF.sub.6 as a driving power supply for a pneumatic motor which ultimately charges a battery or other energy storage device. The stored energy can then be used for instrumentation equipment, or to power any electrical equipment, in the high voltage deck. The accompanying method provides for the use of the SF6 system for operating an electrical device in a high-voltage environment.

  7. Portable High Voltage Impulse Generator

    Directory of Open Access Journals (Sweden)

    S. Gómez

    2011-07-01

    Full Text Available This paper presents a portable high voltage impulse generator which was designed and built with insulation up to 20 kV. This design was based on previous work in which simulation software for standard waves was developed. Commercial components and low-cost components were used in this work; however, these particular elements are not generally used for high voltage applications. The impulse generators used in industry and laboratories are usually expensive; they are built to withstand extra high voltage and they are big, making them impossible to transport. The proposed generator is portable, thereby allowing tests to be made on devices that cannot be moved from their location. The results obtained with the proposed impulse generator were satisfactory in terms of time and waveforms compared to other commercial impulse generators and the standard impulse wave simulator.

  8. Radiatively heated high voltage pyroelectric crystal pulser

    Energy Technology Data Exchange (ETDEWEB)

    Antolak, A.J., E-mail: antolak@sandia.gov [Sandia National Laboratories, Livermore, CA 94550 (United States); Chen, A.X. [Sandia National Laboratories, Livermore, CA 94550 (United States); Leung, K.-N. [Sandia National Laboratories, Livermore, CA 94550 (United States); Nuclear Engineering Department, University of California, Berkeley (United States); Morse, D.H.; Raber, T.N. [Sandia National Laboratories, Livermore, CA 94550 (United States)

    2014-01-21

    Thin lithium tantalate pyroelectric crystals in a multi-stage pulser were heated by quartz lamps during their charging phase to generate high voltage pulses. The charging voltage was determined empirically based on the measured breakdown voltage in air and verified by the induced breakdown voltage of an external high voltage power supply. A four-stage pyroelectric crystal device generated pulse discharges of up to 86 kV using both quartz lamps (radiative) and thermoelectric (conductive) heating. Approximately 50 mJ of electrical energy was harvested from the crystals when radiatively heated in air, and up to 720 mJ was produced when the crystals were submerged in a dielectric fluid. It is anticipated that joule-level pulse discharges could be obtained by employing additional stages and optimizing the heating configuration.

  9. Numerical evaluation of currents induced in a worker by ELF non-uniform electric fields in high voltage substations and comparison with experimental results.

    Science.gov (United States)

    Tarao, Hiroo; Korpinen, Leena H; Kuisti, Harri A; Hayashi, Noriyuki; Elovaara, Jarmo A; Isaka, Katsuo

    2013-01-01

    An ungrounded human, such as a substation worker, receives contact currents when touching a grounded object in electric fields. In this article, contact currents and internal electric fields induced in the human when exposed to non-uniform electric fields at 50 Hz are numerically calculated. This is done using a realistic human model standing at a distance of 0.1-0.5 m from the grounded conductive object. We found that the relationship between the external electric field strength and the contact current obtained by calculation is in good agreement with previous measurements. Calculated results show that the contact currents largely depend on the distance, and that the induced electric fields in the tissues are proportional to the contact current regardless of the non-uniformity of the external electric field. Therefore, it is concluded that the contact current, rather than the spatial average of the external electric field, is more suitable for evaluating electric field dosimetry of tissues. The maximum induced electric field appears in the spinal cord in the central nervous system tissues, with the induced electric field in the spinal cord approaching the basic restriction (100 mV/m) of the new 2010 International Commission on Non-Ionizing Radiation Protection guidelines for occupational exposure, if the contact current is 0.5 mA. Copyright © 2012 Wiley Periodicals, Inc.

  10. Bone and joint changes following electrical burn: plain radiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Uk Jung; Lee, Eil Seong; Shim, Ya Seong; Kim, Seon Bok; Lee, Shin Ho; Jung, Hae Kyoung; Hwang, Dae Hyun; Kang, Ik Won [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1998-10-01

    To evaluate the plain radiographic findings of bone and joint changes following electrical burn. This study involved 19 patients with 27 bone and joints regions which had suffered electrical injury. The most common input and output sites were, respectively, the hand(7/14) and foot (6/10). Three other sites were involved. Four cases involved osteomyelitis, and in four, amputation was performed. We observed bone and joint changes, changes following osteomyelitis and changes in the amputation stump. We analyzed the difference between input and output changes, and when this was interesting, the average time of onset was assessed. In bone and joint changes following electrical burn, the most frequent radiographic finding was joint contracture(n=3D16). Other findings included osteolysis(n=3D8), articular abnormalites (n=3D6), periostitis(n=3D5), fracture(n=3D5), acro-osteolysis(n=3D2), and heterotopic bone formation(n=3D2). In cases involving osteomyelitis(n=3D4), aggravation of underlying bone changes was noted. In electrical burn, various changes were noted in bone and joints, and input injury was more severe than that of output.=20.

  11. [Electrical burns in children. 3 years of case histories].

    Science.gov (United States)

    Caneira, E; Serafim, Z; Duarte, R; Leal, M J

    1996-01-01

    The Burn Unit of Dona Estefânia Hospital admitted a total of 454 patients from January 1992 to January 1995, 24 of these patients suffered from electric shock. Of these 24 patients 3 suffered burns in the mouth, 15 in one or both hands and 6 multiple burns. In 19 patients the burns were up to 1%. A description is made of 5 cases, male children between the ages of 9 and 13 years, which were deemed severe. The incidents occurred outdoors with different voltages and in activities considered of ludic or experimental nature: two on the roof of a house, two with railway cables and one with an electrical cable in a port zone. The burnt areas vary between 4% and 70%, all of them 2nd and 3rd degree, with hospitalization lasting from 36 to 116 days. In addition to early and coordinated medical and rehabilitative treatment, according to individual needs, a description is also made of the cutaneous sequelae (deforming cicatrices, bridles), neurologic and psychologic sequelae, with emphasis on a patient who underwent amputation of the lower left leg and 4th and 5th ranges of the right foot. It was concluded that measures should be taken in education and legislation to prevent these accidents. Relevance is given to the need for a multidisciplinary team and specialized center for the treatment of these patients.

  12. Non-isolated DC-AC converter with high voltage gain for autonomous systems of electric power; Conversor CC-CA nao isolado com alto ganho de tensao para aplicacao em sistemas autonomos de energia eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, George Cajazeiras [Centro Federal de Educacao Tecnologica do Ceara (CEFET/CE), Fortaleza, CE (Brazil); Torrico-Bascope, Rene P. [Universidade Federal do Ceara (PPGEE/UFC), Fortaleza, CE (Brazil). Programa de Pos Graduacao em Engenharia Eletrica; Borges Neto, Manuel Rangel [Centro Federal de Educacao Tecnologica de Petrolina (CEFET-PET), PE (Brazil)

    2008-07-01

    A non-isolated DC-AC converter with high voltage gain with two output sinusoidal voltage - 110 V and 220 V - and frequency 60 Hz for application in autonomous systems of electric power is proposed in this work. This topology consists of a boost converter with high voltage gain, based on three-state switching cell combined with a double half bridge inverter. This configuration type the size and the cost are reduced and the efficiency is gotten better, due to the reduced number of switches. The converters that compose this topology operate with high frequency, reducing the volume of the magnetic materials. can be mention as important characteristics: the voltage stress across the switches of the boost converter are low, due they be naturally clamped by one output filter capacitor, which allows the utilization of switches with lower conduction resistances, and the waveforms of the output voltage of the double half bridge inverter supplies for the load it is sinusoidal and it possesses low harmonic content. (author)

  13. The principle of elaboration of the relay protection against short circuits between the closely placed phases of high voltage electrical line

    Directory of Open Access Journals (Sweden)

    Kiorsak M.

    2015-12-01

    Full Text Available The article is devoted to the elaboration of the principle of relay protection against short circuits between the closely placed phases of higher voltage electrical line with self-compensation, based on the six phase’s symmetrical components. It is shown that the unsymmetrical short circuits between the closely placed phases are characterized by appearance of zero and tertiary sequences of symmetrical components. This fact can be used to choose them for relay protection. The electrical basic circuits and formulas for calculation of the passive parameters of zero and tertiary filters of currents (voltages are done. It is presented the structural-functional basic circuit scheme for relay protection against short circuits between the closely placed phases of higher voltage electrical line with self-compensation.

  14. History of high-voltage ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Singer, E.

    In principle, the feldspar porcelain used for making tableware way back in the 18th century already would have been good enough for electrical purposes, especially for making high-voltage insulators. Thus, further advances in that sector were made for reasons of economy and better process engineering. This would include things like improving the material's green workability. Then, in 1918, Gilchrist and Klinefelter called attention to property changes in the raw materials triangle kaolinquartz-feldspar. Additional glass matrix increases the finished material's dielectric strength, while a larger share of kaolin improves its heat resistance, and a mixture of quartz and feldspar adds more strength.

  15. Living and Working Safely Around High-Voltage Power Lines.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    2001-06-01

    High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

  16. Advances in high voltage engineering

    CERN Document Server

    Haddad, A

    2005-01-01

    This book addresses the very latest research and development issues in high voltage technology and is intended as a reference source for researchers and students in the field, specifically covering developments throughout the past decade. This unique blend of expert authors and comprehensive subject coverage means that this book is ideally suited as a reference source for engineers and academics in the field for years to come.

  17. High Voltage Pulse Testing Survey.

    Science.gov (United States)

    1985-10-01

    Cryogenic 23 E. Liquids 26 F. Solids 28 1. Polyethylene 28 2. Cross-Linked Polyethylene ( XLPE ) 29 3. Polyimide and Polyvenylchloride (PVC) 31 VI Benefits 35 A...Strength of XLPE Cables 29 vii * 4" I PROGRAM OBJECTIVES The Pulse Test Survey summarizes government, industry, and technical reports on high voltage pulse...system of silicone oil on a XLPE (cross-linked polyethylene) spacer tends to lower the impulse breakdown by approximately 10 percent. The negative impulse

  18. TRANSISTOR HIGH VOLTAGE POWER SUPPLY

    Science.gov (United States)

    Driver, G.E.

    1958-07-15

    High voltage, direct current power supplies are described for use with battery powered nuclear detection equipment. The particular advantages of the power supply described, are increased efficiency and reduced size and welght brought about by the use of transistors in the circuit. An important feature resides tn the employment of a pair of transistors in an alternatefiring oscillator circuit having a coupling transformer and other circuit components which are used for interconnecting the various electrodes of the transistors.

  19. Cooling of electrically insulated high voltage electrodes down to 30 mK Kühlung von elektrisch isolierten Hochspannungselektroden bis 30 mK

    CERN Document Server

    Eisel, Thomas; Bremer, J

    2011-01-01

    The Antimatter Experiment: Gravity, Interferometry, Spectroscopy (AEGIS) at the European Organization for Nuclear Research (CERN) is an experiment investigating the influence of earth’s gravitational force upon antimatter. To perform precise measurements the antimatter needs to be cooled to a temperature of 100 mK. This will be done in a Penning trap, formed by several electrodes, which are charged with several kV and have to be individually electrically insulated. The trap is thermally linked to a mixing chamber of a 3He-4He dilution refrigerator. Two link designs are examined, the Rod design and the Sandwich design. The Rod design electrically connects a single electrode with a heat exchanger, immersed in the helium of the mixing chamber, by a copper pin. An alumina ring and the helium electrically insulate the Rod design. The Sandwich uses an electrically insulating sapphire plate sandwiched between the electrode and the mixing chamber. Indium layers on the sapphire plate are applied to improve the ther...

  20. High Voltage in Noble Liquids for High Energy Physics

    Energy Technology Data Exchange (ETDEWEB)

    Rebel, B. [Fermilab; Bernard, E. [Yale U.; Faham, C. H. [LBL, Berkeley; Ito, T. M. [Los Alamos; Lundberg, B. [Maryland U.; Messina, M. [Columbia U.; Monrabal, F. [Valencia U., IFIC; Pereverzev, S. P. [LLNL, Livermore; Resnati, F. [Zurich, ETH; Rowson, P. C. [SLAC; Soderberg, M. [Fermilab; Strauss, T. [Bern U.; Tomas, A. [Imperial Coll., London; Va' vra, J. [SLAC; Wang, H. [UCLA

    2014-08-22

    A workshop was held at Fermilab November 8-9, 2013 to discuss the challenges of using high voltage in noble liquids. The participants spanned the fields of neutrino, dark matter, and electric dipole moment physics. All presentations at the workshop were made in plenary sessions. This document summarizes the experiences and lessons learned from experiments in these fields at developing high voltage systems in noble liquids.

  1. Photon type ultraviolet detection management system in the application of high voltage electrical equipment%光子型紫外检测管理系统在高压电气设备的应用

    Institute of Scientific and Technical Information of China (English)

    黄荣辉; 张宏钊; 姚森敬; 向阳; 段生鹏

    2016-01-01

    With the continuous expansion of grid, power load requirements are constantly improve, the corresponding preventive maintenance requirements and continuously improve. Electrical equipment work in atmospheric environment, with the loss of the insulation performance, can produce corona discharge phenomenon, electrochemical corrosion in the equipment surface, its long time effect on will pose a threat to the safe operation of lines or equipment. At the same time, the abnormal of corona discharge of small discharge phenomenon and the early signs of failure part defects. Electrical equipment in the process of discharge, the radiation of ultraviolet photons outward. Quantitative detection of corona discharge intensity can be used to indirectly assess the status of the equipment operation, real-time control of electric power equipment running status. Photon type ultraviolet imaging system was applied to high voltage electrical equipment inspection work, can make the high voltage electrical equipment maintenance staff to find loopholes, and help the maintenance staff on-site maintenance, has the very good application value.%随着电网规模的不断扩大,电力负荷要求的也不断提高,相应预防性维护的要求也不断提高。电气设备在大气环境下工作,随着绝缘性能的降低,会产生电晕放电现象,使设备表面发生电化学腐蚀,其长时间作用对线路或设备的安全运行会造成威胁。同时,异常的电晕放电发生的微弱放电现象又是部分缺陷故障的早期征兆。电气设备在放电过程中,会向外辐射大量紫外光子。可以利用定量检测电晕放电强度来间接评估运行设备的状况,实时掌握电力设备的运行状态。将光子型紫外成像管理系统应用于高压电气设备的检测工作当中,可使高压电气设备检修工作人员及时发现设备漏洞,并帮助检修工作人员进行现场维修,具有很好的应用价值。

  2. The high voltage homopolar generator

    Science.gov (United States)

    Price, J. H.; Gully, J. H.; Driga, M. D.

    1986-11-01

    System and component design features of proposed high voltage homopolar generator (HVHPG) are described. The system is to have an open circuit voltage of 500 V, a peak output current of 500 kA, 3.25 MJ of stored inertial energy and possess an average magnetic-flux density of 5 T. Stator assembly components are discussed, including the stator, mount structure, hydrostatic bearings, main and motoring brushgears and rotor. Planned operational procedures such as monitoring the rotor to full speed and operation with a superconducting field coil are delineated.

  3. 高压脉冲电场静态处理室的研制%Developing on the Static Chamber of High-Voltage Pulsed Electric Field

    Institute of Scientific and Technical Information of China (English)

    平雪良; 刘翠; 杨瑞金; 赵伟

    2010-01-01

    高压脉冲电场(Pulsed Electric Field, PEF)是一项极具前景的食品非热杀菌技术,其处理关键部件--处理室直接影响杀菌效果.作者设计了电场分布均匀、处理物料容量可调、安全可靠的PEF处理室,应用该PEF处理室对接种大肠杆菌的液蛋进行杀菌,当电场强度为34.2 kV/cm处理时间为400 μs时,原样品菌体浓度为106~107 cfu/mL,大肠杆菌细菌数量降低了约5.05个对数,从而说明作者设计的静态处理室是可行的,可以进行杀菌钝酶等相关机理研究.

  4. Effect of profile and size of isolation trench on the optical and electrical performance of GaN-based high-voltage LEDs

    Science.gov (United States)

    Zhou, Shengjun; Zheng, Chenju; Lv, Jiajiang; Liu, Yingce; Yuan, Shu; Liu, Sheng; Ding, Han

    2016-03-01

    Four types of HV-LEDs with different isolation trench width were presented. The isolation trench with an oblique angle of 45.6° was obtained using a combination of Cl2/BCl3 plasma chemistry and a thermally reflowed photoresist mask layer, enabling conformal metal lines coverage across the isolation trench. The effect of isolation trench width on the optical and electrical characteristics of HV LEDs was also investigated. A quantitative model was developed to analyze light coupling propagation phenomenon occurring within HV LEDs. The suppression of light coupling propagation among adjacent LED cells was achieved by extending isolation trench width from 3.81 μm to 12.30 μm, which improved light extraction efficiency and thus increased light output power of HV LEDs. However, the significantly increasing loss of MQW active region area, which was caused by further extending isolation trench width from 12.30 μm to 40.49 μm, decreased light output power of HV LEDs.

  5. [Analysis of microRNA expression profile in serum of patients with electrical burn or thermal burn].

    Science.gov (United States)

    Ruan, Q F; Jiang, M J; Ye, Z Q; Zhao, C L; Xie, W G

    2017-01-20

    Objective: To explore the differential expression of microRNAs in the serum among patients with electrical burn or thermal burn and healthy persons and to explore the significance. Methods: In this study we included three patients with electrical burn and three patients with thermal burn, conforming to the inclusion criteria and hospitalized in our burn ward from June to August 2015, and three healthy adult volunteers. Their serum samples were separated from whole blood and divided into electrical burn group, thermal burn group, and normal control group. Total RNA was extracted from their serum samples using Trizol method. The differentially expressed microRNAs (with differential ratio larger than or equal to 2.000, less than or equal to 0.500) among the three groups were screened by microRNA chip technique. Then cluster and Venn diagram analysis of the differentially expressed microRNAs were performed. Enrichment analysis of Kyoto encyclopedia of genes and genomes (KEGG) signaling pathway was performed on the distinctly changed microRNAs (with differential ratio larger than or equal to 5.000, less than or equal to 0.500). Results: There were 220 differentially expressed microRNAs among serum of the three groups. MicroRNA expression profiles in serum of electrical burn and thermal burn groups were different from that in serum of normal control group. Compared with those in serum of normal control group, the expressions of 59 microRNAs changed more than 2.000 times in serum of electrical burn group, with 50 up-regulated microRNAs and 9 down-regulated microRNAs; the expressions of 40 microRNAs changed more than 2.000 times in serum of thermal burn group, with 21 up-regulated microRNAs and 19 down-regulated microRNAs. Compared with those in serum of thermal burn group, the expressions of 167 microRNAs changed more than 2.000 times in serum of electrical burn group. There were 17 exclusively expressed microRNAs in serum of thermal burn group and 26 exclusively

  6. 碳纤维复合涂层在高压脉冲电场下的杀菌性能研究%Research on Bactericidal Properties of Carbon Fiber Composite Coatings in High-voltage Pulse Electric Field

    Institute of Scientific and Technical Information of China (English)

    杨鹏鹏; 吴进怡; 柴柯; 林海强; 宋春蕾

    2015-01-01

    ABSTRACT:Objective To explore the inhibition effects and mechanism of high-voltage pulsed electric field ( HPEF) in marine environment on microbial fouling. Methods Carbon fiber / epoxy composite anti-corrosion coating was prepared by brushing meth-od, and the effects of the carbon fiber length and content on the dielectric properties and surface energy of the composite coating as well as the bactericidal performance of the carbon fiber composite coating in high-voltage pulsed electric field. Results The results showed that the carbon fiber length and content were the main factors affecting the dielectric properties of the composite coating un-der high frequency. With the increase of electric field intensity and frequency within the set range, the sterilization rate of the coat-ing obviously increased, while with the increase of duty cycle, the sterilization rate of the coating first increased and then decreased and finally tended to be stable. When the duty cycle was 0. 5, the maximum sterilization rate of 99. 8% was reached. Conclusion The composite coating with a doping content of 0. 1% 5 mm carbon fiber had excellent dielectric properties. High-voltage pulsed e-lectric field had a good killing effect on bacteria and the sterilization rate of the coating could reach 99. 97%.%目的:研究海洋环境下高压脉冲电场对微生物污损的抑制效果和机理。方法采用刷涂法制备碳纤维/环氧防腐涂料复合涂层,研究碳纤维长度和含量对复合涂层的介电性能和表面能的影响以及碳纤维复合涂层在高压脉冲电场作用下的杀菌性能。结果高频电场下,碳纤维长度和含量是影响复合涂层介电性能的主要因素,随着电场强度、频率在设定范围内增加,涂层的杀菌率显著增大;而随占空比的增大,涂层的杀菌率呈先增后减最后趋于平缓的趋势,占空比为0.5时涂层的杀菌率最高达99.8%。结论掺杂0.1%(质量分数)5 mm碳纤维的

  7. Advanced High Voltage Power Device Concepts

    CERN Document Server

    Baliga, B Jayant

    2012-01-01

    Advanced High Voltage Power Device Concepts describes devices utilized in power transmission and distribution equipment, and for very high power motor control in electric trains and steel-mills. Since these devices must be capable of supporting more than 5000-volts in the blocking mode, this books covers operation of devices rated at 5,000-V, 10,000-V and 20,000-V. Advanced concepts (the MCT, the BRT, and the EST) that enable MOS-gated control of power thyristor structures are described and analyzed in detail. In addition, detailed analyses of the silicon IGBT, as well as the silicon carbide MOSFET and IGBT, are provided for comparison purposes. Throughout the book, analytical models are generated to give a better understanding of the physics of operation for all the structures. This book provides readers with: The first comprehensive treatment of high voltage (over 5000-volts) power devices suitable for the power distribution, traction, and motor-control markets;  Analytical formulations for all the device ...

  8. F级高压电机环保型VPI整浸绝缘结构研究%Environmental-friendly VPI Insulation Structure of Grade F High Voltage Electric Motor

    Institute of Scientific and Technical Information of China (English)

    刘晨阳; 尹默

    2012-01-01

    针对国内普通高压电机(6 kV以上)绝缘结构配套的无溶剂绝缘漆在绕组制造过程中产生大量污染环境的挥发性气体,绝缘结构单边绝缘厚度较厚,浪费能源等缺点,采用两家公司生产的绝缘漆进行实验分析,研制出一种新型绝缘结构.结果表明:该新型绝缘结构性价比高,每年能节约可观的电能,还可减少2万多吨CO2排放量.%In view of the disadvantages that the solvent-free insulating varnish for domestic common high voltage electric motor(6 kV) generates large amount of volatile gas during winding process, the structure insulation layer is thick and energy waste, a new insulation structure was developed based on analysis of insulating varnishes. The results show that the insulation structure has a high performance-price ratio, which can save considerable electric energy every year and reduce the emission of CO2 for more than 20, 000 tons/year.

  9. High Voltage Power Transmission for Wind Energy

    Science.gov (United States)

    Kim, Young il

    The high wind speeds and wide available area at sea have recently increased the interests on offshore wind farms in the U.S.A. As offshore wind farms become larger and are placed further from the shore, the power transmission to the onshore grid becomes a key feature. Power transmission of the offshore wind farm, in which good wind conditions and a larger installation area than an onshore site are available, requires the use of submarine cable systems. Therefore, an underground power cable system requires unique design and installation challenges not found in the overhead power cable environment. This paper presents analysis about the benefit and drawbacks of three different transmission solutions: HVAC, LCC/VSC HVDC in the grid connecting offshore wind farms and also analyzed the electrical characteristics of underground cables. In particular, loss of HV (High Voltage) subsea power of the transmission cables was evaluated by the Brakelmann's theory, taking into account the distributions of current and temperature.

  10. High-voltage electrical stimulation for the management of stage III and IV pressure ulcers among adults with spinal cord injury: demonstration of its utility for recalcitrant wounds below the level of injury.

    Science.gov (United States)

    Recio, Albert C; Felter, Cara E; Schneider, Anna Corrine; McDonald, John W

    2012-01-01

    patients with spinal cord injury (SCI) have many factors that are associated with pressure ulcer formation, including paralysis, loss of sensation, poor nutrition, anemia, and skin maceration related to incontinence. Treatment of these ulcers involves relieving pressure, improving nutrition and skin hygiene, treating infections, removing necrotic tissues, and applying the appropriate dressings. However, some cases are not responsive to the above treatment. Electrical stimulation (ES) is thought to enhance soft tissue healing through promotion of protein synthesis, inhibition of bacterial growth, facilitation of epithelial tissue migration, improvement of blood flow, and tensile strength. This data is mainly based on evidence from animal studies and very few rigorously controlled studies conducted in humans. To demonstrate the effectiveness of ES in the treatment of recalcitrant pressure ulcers. Retrospective case series describing the care of adults with SCI and recalcitrant pressure ulcers. ES was applied directly into the wound bed: 60 minutes per session, 3-5 times per week; with an intensity of 100 milliamperes and a frequency of 100 pulses per second. Polarity was negative initially and was switched weekly. The amplitude and wave form were maintained throughout. The long-standing (11-14 months) pressure ulcers were completely healed after 7 to 22 weeks of treatment with high-voltage ES. This case series demonstrates the effectiveness of ES for enhanced healing of Stage III-IV ulcers otherwise unresponsive to standard wound care. Further study is needed to identify the most effective protocol for ES therapy in the treatment of recalcitrant pressure ulcers.

  11. 高压电力计量系统故障诊断与应用研究%The Fault Diagnosis and Applied Research of High Voltage Electric Power Metering System

    Institute of Scientific and Technical Information of China (English)

    王娟; 张瑾

    2013-01-01

    提出了一种新的应用于高压电力计量系统的电流互感器一次侧短路的故障检测方法.首先,通过理论分析得出网络阻抗与电流互感器一次侧短路之间的密切关系.其次,设计故障检测方法,对故障信号进行分析和研究.最后得出了一种在实际应用中可行的方案.%A new fault detection method of short circuit of the primary side of TA applied to high voltage electric power metering system is proposed.Firstly,through theory analysis the close relationship between network impedance and short circuit of the primary side of TA are obtained.Secondly,the method of fault detection to research and analyze the fault signal is designed.Lastly,a plan is obtained that is feasible in practical application.

  12. V法铸造在高压电器铝筒体生产上的应用%Application of V Method Casting in High Voltage Electric Apparatus Aluminum Cylinder Production

    Institute of Scientific and Technical Information of China (English)

    王赏; 谷喜秀

    2014-01-01

    Introduction was made to that the high voltage electrical apparatus large-sized aluminum cylinder was produced by using V method casting technology , melting in medium frequency induction oven plus fining oven and adopting bottom pouring open type double pouring path pouring system. Analysis was made to the impacts of different technological parameters on casting aluminum cylinder. Batch production test verification has passed, which provides technical support for using V method to cast aluminum cylin-der in the future.%介绍了利用V法铸造工艺,使用中频感应炉加精炼炉熔炼,采用底注开放式双浇道的浇注系统,来生产高压电器大型铝筒体,分析了不同工艺参数对铸造铝筒体的影响。通过批量生产试验验证,为今后使用V法铸造生产铝筒体提供了技术支持。

  13. High voltage switches having one or more floating conductor layers

    Energy Technology Data Exchange (ETDEWEB)

    Werne, Roger W.; Sampayan, Stephen; Harris, John Richardson

    2015-11-24

    This patent document discloses high voltage switches that include one or more electrically floating conductor layers that are isolated from one another in the dielectric medium between the top and bottom switch electrodes. The presence of the one or more electrically floating conductor layers between the top and bottom switch electrodes allow the dielectric medium between the top and bottom switch electrodes to exhibit a higher breakdown voltage than the breakdown voltage when the one or more electrically floating conductor layers are not present between the top and bottom switch electrodes. This increased breakdown voltage in the presence of one or more electrically floating conductor layers in a dielectric medium enables the switch to supply a higher voltage for various high voltage circuits and electric systems.

  14. New energy management circuit applied in electric self-power supply over high voltage side%新型高压侧自供电电源设计与研究

    Institute of Scientific and Technical Information of China (English)

    李衍川; 江和

    2014-01-01

    分析了高压电场能量收集的原理,建立静电场耦合分布电容模型,并通过实验证明了模型的参考价值。随后,分析使用整流桥电路进行能量管理时的最佳功率点,并从增大超级电容充电电流的角度,设计了一种新型的管理电路,即同步电荷提取电路,以获得最佳的能量存储能力。结果证明存在一个最佳占空比使得收集的能量最大化,从而缩短无线节点在线监测工作周期。%The theory of energy harvested from the high voltage is analyzed, and then the corresponding model of coupling capacitance derived from static electric field is built, and several experiments are conducted to study whether the model is valuable. Then, according to what the result reveals, the optimal power point is found out when energy is managed by rectifier circuit. The value of charged current to super capacitor is used as the judge-ment whether the circuit system has the best storage performance. In that respect, management circuit is improved as a technology called Synchronous Electric Charge Extract, because the rectifier circuit can’ t perform as good as it is under ultrahigh voltage. It turns out that there is an optimal duty to maximize the energy harvested, so that the energy harvester can scavenge much more energy to cancellout the power loss. As a result, online monitoring period could be shortened greatly.

  15. Intense neutron source: high-voltage power supply specifications

    Energy Technology Data Exchange (ETDEWEB)

    Riedel, A.A.

    1980-08-01

    This report explains the need for and sets forth the electrical, mechanical and safety specifications for a high-voltage power supply to be used with the intense neutron source. It contains sufficient information for a supplier to bid on such a power supply.

  16. Space charge accumulation in polymeric high voltage DC cable systems

    NARCIS (Netherlands)

    Bodega, R.

    2006-01-01

    One of the intrinsic properties of the polymeric high voltage (HV) direct current (DC) cable insulation is the accumulation of electrostatic charges. Accumulated charges distort the initial Laplacian distribution of the electric field, leading to a local field enhancement that may cause insulation d

  17. An optical remote controlled high voltage dome for electron microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Ruan, S. [The Enrico Fermi Institute, The University of Chicago, Chicago, Illinois 60637 (United States); Kapp, O.H. [The Department of Radiology and the Enrico Fermi Institute, The University of Chicago, Chicago, Illinois 60637 (United States)

    1995-08-01

    A low cost high voltage dome has been completed for an electron microscope with a thermal emission tip as electron source. Two fibers are used to provide communication across the high electrical field zone between the computer and the dome. This system provides a reliable method to operate the dome circuitry (floating at high voltage) and ensures the safety of both the computer system and the operator. Because of the application of ``dummy`` serial data transfer, the least number of fibers and associated components are used, providing a relatively low-cost solution to this problem. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  18. Temperature Stabilized Characterization of High Voltage Power Supplies

    CERN Document Server

    Krarup, Ole

    2017-01-01

    High precision measurements of the masses of nuclear ions in the ISOLTRAP experiment relies on an MR-ToF. A major source of noise and drift is the instability of the high voltage power supplies employed. Electrical noise and temperature changes can broaden peaks in time-of-flight spectra and shift the position of peaks between runs. In this report we investigate how the noise and drift of high-voltage power supplies can be characterized. Results indicate that analog power supplies generally have better relative stability than digitally controlled ones, and that the high temperature coefficients of all power supplies merit efforts to stabilize them.

  19. Reliability and Characterization of High Voltage Power Capacitors

    Science.gov (United States)

    2014-03-01

    ix LIST OF FIGURES Figure 1.   System level overview of IPC EVCS (from [3]). ..............................................2   Figure 2...permittivity EVCS electric vehicle charging system GPIB general-purpose interface bus GW giga-watt HVST high voltage stress test IV current voltage...Power Converter (IPC). This converter is being used for the Electric Vehicle Charging Station ( EVCS ), currently being investigated and installed in

  20. Application of Double Elbow-bar Upsetting and Shape-forming Technique to Production of High-voltage Electrical Product%双肘杆镦锻成形工艺的应用

    Institute of Scientific and Technical Information of China (English)

    武泾元; 高励学

    2013-01-01

    高压电气产品中,活塞杆和接头类零件属于关键零件,且应用较多,这类零件属于长轴类带法兰件,目前,采用的加工方式是用棒料直接加工成形,材料利用率低,工艺性差.笔者分析了活塞杆和接头类零件的形状特点,认为采用双肘杆镦锻工艺制坯,解决了材料浪费问题,降低了零件制造成本,提高了零件抗拉强度.阐述了双肘杆镦锻模具设计、成形工艺、热处理工艺等方面的内容.%Piston rods and connector-type parts are critical parts in high-voltage electrical products. These parts belong to' long axis with flange' class, and the existing shape-forming process is of directly machining bar with low material utilization and efficiency. In this paper, shape features of the piston rods and connector-type parts are analyzed, and double elbow-bar upsetting technique is suggested to save material, shorten processing time, reduce manufacturing costs and increase tensile intensity of the parts. Moreover, the design of double elbow-bar upsetting mold, the molding process, and the heat treatment are discussed.

  1. Treatment and follow-up results of children with electrical burn who observed in burn intensive care unit

    Directory of Open Access Journals (Sweden)

    Çiğdem Aliosmanoğlu

    2011-06-01

    Full Text Available Electrical burns are infrequent relative to other injuries, but they are associated with high morbidity and mortality. The aim of this study was to assess management and follow-up results of pediatric patients’ who observed in intensive care unit and also review the precautions for preventing electrical burns.Materials and methods: Totally 22 patients aged under 17 years who were observed in the burn intensive care unit of Şanlıurfa Education and Research Hospital during the period between July 2009-October 2010. Cases were investigated retrospectively. The patients’ age, gender, total burn surface area, length of stay in hospital, musculo-skeletal system complication, cardiovascular system complication, kidney damage and attempts were recorded.Results: Of the 22 cases, 19 (86.3% were male and 3 (13.7% were female. The mean age of the patients was 11.5 years. In 10 (45.4% children burns were occurred in workplace and working area and 12 (54.6% were occurred in the home environment. Depth of burns were third degree in 10 (45.4% children and second degree in 12 (54.6%. The mean percentage of burn surface area was 25.9%. The mean length of stay in hospital was 17 days. Debridement and grafting were performed to 12 (54.6% cases and 10 (45.4% children were treated with dressings. No patient had increased creatinine kinase levels, oliguria, myoglobuinuria and arrhythmia. The mean hospitalization time was 17 days.Conclusion: Nearly half of patients underwent debridement plus grafting. None of our patients developed renal failure other severe system dysfunction.

  2. Optimization of condition for improving sorghum seed vigor by high voltage electric field%优化高压电场处理提高高粱种子活力

    Institute of Scientific and Technical Information of China (English)

    胡建芳; 陈建中; 王玉国; 杜慧玲

    2015-01-01

    为了探讨高压电场处理对高粱种子萌发活力的影响,以晋杂122#高粱种子为试材,采用种子发芽试验、生物化学分析及二次通用旋转组合设计相结合的方法,研究电场强度和处理时间对高粱种子的活力指数和内源赤霉素(gibberellin,GA)含量的影响,通过建模分析,寻求高压电场处理条件的优化方案。结果表明:不同高压电场(high voltage electric field,HVEF)处理对高粱种子活力指数和内源GA含量影响均达到显著水平(P<0.05);二因素对高粱种子的活力指数和内源GA含量影响效应顺序为电场强度>处理时间;电场强度和处理时间对高粱种子活力指数和内源GA含量影响有阈值效应;二因素耦合效应对高粱种子的活力指数的影响呈现负交互效应,对内源 GA 含量的影响表现出正交互效应,且交互效应显著(P<0.05),二因素交互作用对内源GA含量影响大于对种子活力的影响;经模型寻优,同时满足活力指数≥14.25、内源GA质量分数≥11.55 ng/g的优化方案为:电场强度485.53~605.38 kV/m,处理时间31.41~48.99 min,在此基础上,进一步确定优化条件为:电场强度500 kV/m,处理时间36 min,经试验验证,高粱种子活力指数和内源GA质量分数理论值15.50、14.92 ng/g,与实测值(15.38±0.18)、(14.85±0.13)ng/g基本一致,进一步验证了方案的可靠性。研究结果为高压电场技术处理种子在农业生产中的应用提供理论依据。%Physical agricultural technique that plant seeds are treated by high voltage electric field (HVEF) is a kind of simple method and has characteristics of high efficiency, short processing time, low power and no pollution, etc, which has become a hot research subject in agriculture field. However, the researches of sorghum seeds treated with HVEF haven’t been under way. Some researches suggest that the features of biotic

  3. Advances in high voltage insulation and arc interruption in SF6 and vacuum

    CERN Document Server

    Maller, V N

    1982-01-01

    Advances in High Voltage Insulation and Arc Interruption in SF6 and Vacuum deals with high voltage breakdown and arc extinction in sulfur hexafluoride (SF6) and high vacuum, with special emphasis on the application of these insulating media in high voltage power apparatus and devices. The design and developmental aspects of various high voltage power apparatus using SF6 and high vacuum are highlighted. This book is comprised of eight chapters and opens with a discussion on electrical discharges in SF6 and high vacuum, along with the properties and handling of SF6 gas. The following chapters fo

  4. 30 CFR 56.12071 - Movement or operation of equipment near high-voltage power lines.

    Science.gov (United States)

    2010-07-01

    ...-voltage power lines. 56.12071 Section 56.12071 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... NONMETAL MINES Electricity § 56.12071 Movement or operation of equipment near high-voltage power lines. When equipment must be moved or operated near energized high-voltage powerlines (other than...

  5. High Voltage Applications of Explosively Formed Fuses

    Science.gov (United States)

    Tasker, D. G.; Goforth, J. H.; Fowler, C. M.; Herrera, D. H.; King, J. C.; Lopez, E. A.; Martinez, E. C.; Oona, H.; Marsh, S. P.; Reinovsky, R. E.; Stokes, J.; Tabaka, L. J.; Torres, D. T.; Sena, F. C.; Kiuttu, G.; Degnan, J.

    2004-11-01

    At Los Alamos, we have primarily applied Explosively Formed Fuse (EFF) techniques to high current systems. In these systems, the EFF has interrupted currents from 19-25 MA, thus diverting the current to low inductance loads. The transferred current magnitude is determined by the ratio of storage inductance to load inductance and, with dynamic loads, the current has ranged from 12-20 MA. In a system with 18 MJ stored energy, the switch operates at a power of up to 6 TW. We are now investigating the use of the EFF technique to apply high voltages to high impedance loads in systems that are more compact. In these systems we are exploring circuits with EFF lengths from 43-100 cm, which have storage inductances large enough to apply 300-500 kV across high impedance loads. Experimental results and design considerations are presented. Using cylindrical EFF switches of 10 cm diameter and 43 cm length, currents of approximately 3 MA were interrupted producing ~200 kV. This indicates the switch had an effective resistance of ~100 mΩ where 150-200 mΩ was expected. To understand the lower performance, several parameters were studied including electrical conduction through the explosive products; current density; explosive initiation; insulator type and conductor thickness. The results show a number of interesting features, most notably that the primary mechanism of switch operation is mechanical and not electrical fusing of the conductor. Switches opening on a 1-10 μs time scale with resistances starting at 50 μΩ and increasing to perhaps 1 Ω now seem possible to construct using explosive charges as small as a few pounds.

  6. Properties of Polymer Composites Used in High-Voltage Applications

    Directory of Open Access Journals (Sweden)

    Ilona Pleşa

    2016-04-01

    Full Text Available The present review article represents a comprehensive study on polymer micro/nanocomposites that are used in high-voltage applications. Particular focus is on the structure-property relationship of composite materials used in power engineering, by exploiting fundamental theory as well as numerical/analytical models and the influence of material design on electrical, mechanical and thermal properties. In addition to describing the scientific development of micro/nanocomposites electrical features desired in power engineering, the study is mainly focused on the electrical properties of insulating materials, particularly cross-linked polyethylene (XLPE and epoxy resins, unfilled and filled with different types of filler. Polymer micro/nanocomposites based on XLPE and epoxy resins are usually used as insulating systems for high-voltage applications, such as: cables, generators, motors, cast resin dry-type transformers, etc. Furthermore, this paper includes ample discussions regarding the advantages and disadvantages resulting in the electrical, mechanical and thermal properties by the addition of micro- and nanofillers into the base polymer. The study goals are to determine the impact of filler size, type and distribution of the particles into the polymer matrix on the electrical, mechanical and thermal properties of the polymer micro/nanocomposites compared to the neat polymer and traditionally materials used as insulation systems in high-voltage engineering. Properties such as electrical conductivity, relative permittivity, dielectric losses, partial discharges, erosion resistance, space charge behavior, electric breakdown, tracking and electrical tree resistance, thermal conductivity, tensile strength and modulus, elongation at break of micro- and nanocomposites based on epoxy resin and XLPE are analyzed. Finally, it was concluded that the use of polymer micro/nanocomposites in electrical engineering is very promising and further research work

  7. Computer Controlled High Precise,High Voltage Pules Generator

    Institute of Scientific and Technical Information of China (English)

    但果; 邹积岩; 丛吉远; 董恩源

    2003-01-01

    High precise, high voltage pulse generator made up of high-power IGBT and pulse transformers controlled by a computer are described. A simple main circuit topology employed in this pulse generator can reduce the cost meanwhile it still meets special requirements for pulsed electric fields (PEFs) in food process. The pulse generator utilizes a complex programmable logic device (CPLD) to generate trigger signals. Pulse-frequency, pulse-width and pulse-number are controlled via RS232 bus by a computer. The high voltage pulse generator well suits to the application for fluid food non-thermal effect in pulsed electric fields, for it can increase and decrease by the step length 1.

  8. Cardiac stimulation with high voltage discharge from stun guns.

    Science.gov (United States)

    Nanthakumar, Kumaraswamy; Massé, Stephane; Umapathy, Karthikeyan; Dorian, Paul; Sevaptsidis, Elias; Waxman, Menashe

    2008-05-20

    The ability of an electrical discharge to stimulate the heart depends on the duration of the pulse, the voltage and the current density that reaches the heart. Stun guns deliver very short electrical pulses with minimal amount of current at high voltages. We discuss external stimulation of the heart by high voltage discharges and review studies that have evaluated the potential of stun guns to stimulate cardiac muscle. Despite theoretical analyses and animal studies which suggest that stun guns cannot and do not affect the heart, 3 independent investigators have shown cardiac stimulation by stun guns. Additional research studies involving people are needed to resolve the conflicting theoretical and experimental findings and to aid in the design of stun guns that are unable to stimulate the heart.

  9. Ultra-compact Marx-type high-voltage generator

    Science.gov (United States)

    Goerz, David A.; Wilson, Michael J.

    2000-01-01

    An ultra-compact Marx-type high-voltage generator includes individual high-performance components that are closely coupled and integrated into an extremely compact assembly. In one embodiment, a repetitively-switched, ultra-compact Marx generator includes low-profile, annular-shaped, high-voltage, ceramic capacitors with contoured edges and coplanar extended electrodes used for primary energy storage; low-profile, low-inductance, high-voltage, pressurized gas switches with compact gas envelopes suitably designed to be integrated with the annular capacitors; feed-forward, high-voltage, ceramic capacitors attached across successive switch-capacitor-switch stages to couple the necessary energy forward to sufficiently overvoltage the spark gap of the next in-line switch; optimally shaped electrodes and insulator surfaces to reduce electric field stresses in the weakest regions where dissimilar materials meet, and to spread the fields more evenly throughout the dielectric materials, allowing them to operate closer to their intrinsic breakdown levels; and uses manufacturing and assembly methods to integrate the capacitors and switches into stages that can be arranged into a low-profile Marx generator.

  10. 高压输电线环境电磁场暴露健康效应的原初作用%Primary Reaction for the Environmental Electric and Magnetic Fields Exposure Around High Voltage Transmission Line on Health Effects

    Institute of Scientific and Technical Information of China (English)

    王琴; 苏海峰; 包家立; 李宇波; 朱朝阳

    2013-01-01

    高压输电线环境电磁场暴露健康效应的原初作用机制是阐述电磁健康的环节,是制修订我国环境电磁标准的重要基础.为此,对220 kV的高压输电线环境电磁场进行了现场监测,将SD大鼠海马神经元暴露在瑞士IT'IS系统中,观察胞内活性氧自由基(ROS)、钙离子(Ca2+)和线粒体膜电位(MMP)对磁感应强度为0.1 mT、0.5mT和1.0 mT的极低频电磁场的生物响应.研究结果表明:环境电场强度≤1 kV/rn,磁场磁感应强度≤1.5 μT;神经元胞内活性氧自由基、钙离子、线粒体膜电位对磁感应强度≥0.1 mT的磁场有生物反应.因此,电场能量密度和磁场能量密度可作为电磁健康效应的评价参数;ROS是电磁因果链原初作用中连接物理和生物解释的一个重要标志物;足够强度的电磁场才能对健康产生影响,笼统说“电磁场对健康有影响”会误导公众.%We measured an environment electric and magnetic fields around 220 kV high voltage transmission line, and observed some responses of reactive oxygen species (ROS) , calcium (Ca2+ ) , and the mitochondrial membrane potential(MMP) in the hippocampus neurons from SD rat exposed to 0. 1 mT, 0. 5 mT and 1. 0 mT extremely low frequency electromagnetic fields in IT' IS system. Results show that the environment electric field is not more than 1 kV/m and the magnetic field is not more than 1. 5 μT, and there are some ROS, Ca2+ , MMP responses in the neurons to magnetic field no less than 0. 1 mT. So the electromagnetic energy may be an electromagnetic parameter for evaluation of health effects. ROS is a marker of electromagnetic health effects for physical explanation and a biological explanation. Only enough strength electromagnetic fields can affect health.

  11. Pattern of burn injury in hang-glider pilots.

    Science.gov (United States)

    Campbell, D C; Nano, T; Pegg, S P

    1996-06-01

    High-voltage electrical injury has been well documented in a number of situations, such as the occupational hazard of linesmen and construction workers, and in the context of overhead railway power lines. Two cases of hang-glider pilots contacting 11,000-volt power lines have recently been treated in the Royal Brisbane Hospital Burns Unit. They demonstrate an interesting pattern of injury, not described in current burns literature, involving both hand and lower abdominal burns. Both patients sustained full-thickness patches of burn injury, with underlying muscle damage and peripheral neurological injury. This distribution of injury seems to be closely related to the design of the hang glider.

  12. Fatal and non-fatal burn injuries with electrical weapons and explosive fumes.

    Science.gov (United States)

    Kroll, Mark W; Ritter, Mollie B; Williams, Howard E

    2017-08-01

    While generally reducing morbidity and mortality, electrical weapons have risks associated with their usage, including eye injuries and falls. With the presence of explosive fumes or fuels there also exists the possibility of burn injury. We searched for cases of fatal and non-fatal major burns with TASER(®) electrical weapon usage where there was a possibility that the weapon ignited the explosion. We confirmed 6 cases of fatal burn injury and 4 cases of major non-fatal burns out of 3.17 million field uses. The mean age was 35.5 ± 9.7 years which is consistent with the typical arrest-related death. Moderate, minor, and noninjurious fires - typically due to a cigarette lighters in a pocket, petrol, recreational inhalants, or body spray were also noted. The use of electrical weapons presents a small but real risk of death from fatal burn injury. It also presents a small risk of major non-fatal burn injury. The ignition of petrol fumes dominates these cases of major fatal and nonfatal burns. Copyright © 2017 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  13. Efeito da estimulação elétrica de alta voltagem catódica sobre a dor em mulheres com DTM Effect of cathodal high-voltage electrical stimulation on pain in women with TMD

    Directory of Open Access Journals (Sweden)

    Natalia C. M. C. Gomes

    2012-02-01

    Full Text Available CONTEXTUALIZAÇÃO: A dor é o principal sintoma dos pacientes com disfunção temporomandibular (DTM. OBJETIVO: Avaliar o efeito da estimulação elétrica de alta voltagem catódica (EEAV sobre a intensidade da dor em mulheres com DTM. MÉTODOS: Participaram do estudo 20 mulheres (24,25±8,90 anos com DTM, divididas em grupo experimental (GE n=10, no qual as mulheres receberam dez aplicações de EEAV, e grupo placebo (GP n=10, no qual foi aplicada a EEAV, porém com o aparelho desligado. Para seleção da amostra, utilizou-se o critério de diagnóstico em pesquisa para DTM (RDC/TMD e, para avaliação da dor, utilizou-se a Escala Visual Analógica (EVA aplicada antes do início do tratamento (pré-tratamento e após a décima aplicação da EEAV (pós-tratamento. Os dados foram analisados pelos testes Wilcoxon das ordens assinaladas e Mann-Whitney. RESULTADOS: As dez aplicações de EEAV promoveram redução da intensidade da dor no GE (p=0,01; no GP, não se observou diferença significativa (p=0,20. Comparando-se os grupos após a aplicação da EEAV, não se notou diferença (p=0,65. CONCLUSÃO: A EEAV catódica é efetiva para redução da dor em mulheres com DTM. Registro de Ensaio Clinico RBR-4bk94x.BACKGROUND: Pain is the main symptom of patients with temporomandibular disorder (TMD. OBJECTIVE: To evaluate the effect of cathodal high-voltage electrical stimulation (HVES on pain intensity in women with TMD. METHODS: Twenty women with TMD (24.25±8.90 years old participated in the study. They were divided into experimental group (EG, n=10, which received 10 applications of HVES, and placebo group (PG, n=10, which received sham treatment with disconnected HVES equipment. For the sample selection, we used the Research Diagnostic Criteria for Temporomandibular Disorder (RDC/TMD. Pain level was evaluated using a visual analog scale (VAS applied prior to and after the tenth application of HVES. Data were analyzed using the Wilcoxon signed

  14. Electric field selective optical data storage using persistent spectral hole burning

    Science.gov (United States)

    Bogner, U.; Beck, K.; Maier, Max

    1985-03-01

    The electric field domain is used as a storage dimension in optical data storage by persistent spectral hole burning. The memory locations in the electric field domain are addressed with the voltage applied to the sample consisting of the amorphous polymer polyvinyl-butyral doped with the dye 9-amino acridine. The information is written by burning spectral holes at different electric field strengths with a HeCd laser and read by detecting the presence or absence of holes with weak laser intensity.

  15. Correlation of renal complications with extent and progression of tissue damage in electrical burns

    Directory of Open Access Journals (Sweden)

    Chauhan D

    2004-01-01

    Full Text Available Electrical injuries due to high-tension voltage (>1000 volts cause destruction at the point of contact with massive necrosis of deeper structures such as muscles, vessels and nerves. Rhabdomyolysis due to massive breakdown of skeletal muscles may lead to acute renal failure secondary to myoglobinuria. The study was undertaken to observe the correlation of renal complications with extent and progression of tissue damage in high-tension voltage electrical burns. Renal biochemical parameters as predictors of acute renal failure were also studied. Thirty two patients of high tension voltage electrical burn injuries presenting during one year period 1-1-2001 to 31-12-2001 were studied. Low-tension voltage electrical injuries (< 1000 volts mimic thermal burns were excluded from the study. The electrical wound assessment and the renal biochemical parameters were done daily for the first seven days and then on alternate days for another seven days. Assessment of progression of wounds and correlation with the renal biochemical parameters was done. Patients who died following electrical burns were subjected to autopsy and histopathological examination of both kidneys. Out of the thirty-two patients, six (18.75% went into acute renal failure. Five out of these six patients died because of renal failure (mortality rate 83.33%. There was definite progression of electric burn wounds. There was no correlation between progression of electrical burn wounds and acute renal failure. Serum creatinine was found to be the most important biochemical parameter as a prognostic indicator of acute renal failure.

  16. Eradication of multidrug-resistant A. baumannii in burn wounds by antiseptic pulsed electric field.

    Science.gov (United States)

    Golberg, Alexander; Broelsch, G Felix; Vecchio, Daniela; Khan, Saiqa; Hamblin, Michael R; Austen, William G; Sheridan, Robert L; Yarmush, Martin L

    2014-06-01

    Emerging bacterial resistance to multiple drugs is an increasing problem in burn wound management. New non-pharmacologic interventions are needed for burn wound disinfection. Here we report on a novel physical method for disinfection: antiseptic pulsed electric field (PEF) applied externally to the infected burns. In a mice model, we show that PEF can reduce the load of multidrug resistant Acinetobacter baumannii present in a full thickness burn wound by more than four orders of magnitude, as detected by bioluminescence imaging. Furthermore, using a finite element numerical model, we demonstrate that PEF provides non-thermal, homogeneous, full thickness treatment for the burn wound, thus, overcoming the limitation of treatment depth for many topical antimicrobials. These modeling tools and our in vivo results will be extremely useful for further translation of the PEF technology to the clinical setting, as they provide the essential elements for planning of electrode design and treatment protocol.

  17. [Preclinical treatment of severe burn trauma due to an electric arc on an overhead railway cable].

    Science.gov (United States)

    Spelten, O; Wetsch, W A; Hinkelbein, J

    2013-09-01

    Severe burns due to electrical accidents occur rarely in Germany but represent a challenge for emergency physicians and their team. Apart from extensive burns cardiac arrhythmia, neurological damage caused by electric current and osseous injury corresponding to the trauma mechanism are also common. It is important to perform a survey of the pattern of injuries and treat acute life-threatening conditions immediately in the field. Furthermore, specific conditions related to burns must be considered, e.g. fluid resuscitation, thermal management and analgesia. In addition, a correct strategy for further medical care in an appropriate hospital is essential. Exemplified by this case guidelines for the treatment of severe burns and typical pitfalls are presented.

  18. The Dynamic Fracture Process in Rocks Under High-Voltage Pulse Fragmentation

    Science.gov (United States)

    Cho, Sang Ho; Cheong, Sang Sun; Yokota, Mitsuhiro; Kaneko, Katsuhiko

    2016-10-01

    High-voltage pulse technology has been applied to rock excavation, liberation of microfossils, drilling of rocks, oil and water stimulation, cleaning castings, and recycling products like concrete and electrical appliances. In the field of rock mechanics, research interest has focused on the use of high-voltage pulse technology for drilling and cutting rocks over the past several decades. In the use of high-voltage pulse technology for drilling and cutting rocks, it is important to understand the fragmentation mechanism in rocks subjected to high-voltage discharge pulses to improve the effectiveness of drilling and cutting technologies. The process of drilling rocks using high-voltage discharge is employed because it generates electrical breakdown inside the rocks between the anode and cathode. In this study, seven rock types and a cement paste were electrically fractured using high-voltage pulse discharge to investigate their dielectric breakdown properties. The dielectric breakdown strengths of the samples were compared with their physical and mechanical properties. The samples with dielectric fractured were scanned using a high-resolution X-ray computed tomography system to observe the fracture formation associated with mineral constituents. The fracture patterns of the rock samples were analyzed using numerical simulation for high-voltage pulse-induced fragmentation that adopts the surface traction and internal body force conditions.

  19. Burns

    Science.gov (United States)

    To help prevent burns: Install smoke alarms in your home. Check and change batteries regularly. Teach children about fire safety and the danger of matches and fireworks. Keep children from climbing on top of a stove ...

  20. The VELO High Voltage System Control Software

    CERN Document Server

    Rakotomiaramanana, B; Eklund, L; De Capua, S

    2010-01-01

    This note describes the VELO high voltage control software. The implementation of its structure as a PVSS Finite State Machine is emphasized. The main error conditions that may occur during operation is also discussed. The VELO HV software conforms to the specification of the VELO.

  1. Characterisation of the VELO High Voltage System

    CERN Document Server

    Rakotomiaramanana, B; Eklund, L

    2008-01-01

    The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; vercation of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence th...

  2. Characterisation of the VELO High Voltage System

    CERN Document Server

    Rakotomiaramanana, B; Parkes, C; Eklund, L

    2008-01-01

    The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; verification of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence...

  3. Modeling of long High Voltage AC Underground

    DEFF Research Database (Denmark)

    Gudmundsdottir, Unnur Stella; Bak, Claus Leth; Wiechowski, W. T.

    2010-01-01

    This paper presents the work and findings of a PhD project focused on accurate high frequency modelling of long High Voltage AC Underground cables. The project is cooperation between Aalborg University and Energinet.dk. The objective of the project is to investigate the accuracy of most up to date...

  4. An Inexpensive Source of High Voltage

    Science.gov (United States)

    Saraiva, Carlos

    2012-01-01

    As a physics teacher I like recycling old apparatus and using them for demonstrations in my classes. In physics laboratories in schools, sources of high voltage include induction coils or electronic systems that can be bought from companies that sell lab equipment. But these sources can be very expensive. In this article, I will explain how you…

  5. 14,000 volt electrical injury to bilateral upper extremities: a case report.

    Science.gov (United States)

    Lee, J; Sinno, H; Perkins, A; Tahiri, Y; Luc, M

    2011-06-01

    Electrical burns are among the most devastating of burn injuries. High voltage electrical injuries result in extensive deep tissue damage and are associated with multiple complications, long term morbidity, and a high mortality rate. We describe the case of a 47 year-old electric company linesman who suffered a high voltage electrical injury (HVEI) of 14,000 volts to bilateral hands and wrists managed by the Division of Plastic and Reconstructive Surgery at the McGill University Health Center in Montreal, Quebec, Canada. His management included multiple operative procedures, including escharotomies, fasciotomies, serial debridements, and bilateral pedicle groin flaps, and amputation of his left hand.

  6. Bottlenecks reduction using superconductors in high voltage transmission lines

    Directory of Open Access Journals (Sweden)

    Daloub Labib

    2016-01-01

    Full Text Available Energy flow bottlenecks in high voltage transmission lines known as congestions are one of the challenges facing power utilities in fast developing countries. Bottlenecks occur in selected power lines when transmission systems are operated at or beyond their transfer limits. In these cases, congestions result in preventing new power supply contracts, infeasibility in existing contracts, price spike and market power abuse. The “Superconductor Technology” in electric power transmission cables has been used as a solution to solve the problem of bottlenecks in energy transmission at high voltage underground cables and overhead lines. The increase in demand on power generation and transmission happening due to fast development and linked to the intensive usage of transmission network in certain points, which in turn, lead to often frequent congestion in getting the required power across to where it is needed. In this paper, a bottleneck in high voltage double overhead transmission line with Aluminum Conductor Steel Reinforced was modeled using conductor parameters and replaced by Gap-Type Superconductor to assess the benefit of upgrading to higher temperature superconductor and obtain higher current carrying capacity. This proved to reduce the high loading of traditional aluminum conductors and allow more power transfer over the line using superconductor within the same existing right-of-way, steel towers, insulators and fittings, thus reducing the upgrade cost of building new lines.

  7. Health problems from radiation of high-voltage facilities

    Directory of Open Access Journals (Sweden)

    Hossein Ali Yousefi Rizi

    2013-01-01

    Full Text Available Aims: The aim of this study was to survey the health problems caused by exposure to high-voltage facility radiation. Materials and Methods: Sampling included workers exposed to electromagnetic fields at high-voltage facilities. The strength of the electric and magnetic fields was determined by a field meter. A questionnaire was used to evaluate the prevalence of subjective and psychological symptoms. Statistical descriptive used and data analyzed by a Student′s t-tests. Results: This study indicates that increased symptoms among the exposed workers including depression, anxiety, hostility, paranoia, inter-sensitivity, and obsession-compulsion. Some of the self-reported symptoms were, headache (53.5%, fatigue (35.6%, difficulties in concentration (32.5%, vertigo/dizziness (30.4%, attention disorders (28.8%, nervousness (28.1%, and palpitations (14.7%. A significant relationship was observed between the exposure to the electromagnetic field and psychological symptoms (P < 0.05. Conclusion: Radiation of high-voltage facilities probably increased the risk of mental disorders and intensified them in susceptible workers, especially depression. This finding confirmed the results obtained in provocative studies that indicated an increase in the risk of psychological symptoms, which was put forth by several investigators Observation of occupational health and other control measures play an important role in decreasing the symptoms.

  8. Development and application of pulsed electric field instrument with extremely low frequency and high-voltage for biological effects%极低频高压脉冲电场生物学效应仪的设计与应用

    Institute of Scientific and Technical Information of China (English)

    杨运经; 习岗; 张社奇; 刘锴; 张晓辉

    2012-01-01

    In order to carry out the study of biological effects on extremely low frequency high-voltage pulsed electric field, a pulsed electric field generator based on potential fluctuation in plant was designed. The system can produce high-voltage pulse with extremely low frequency, wide pulse width and steep front. The amplitude of voltage is adjustable from 6 to 20 kV and the pulse frequency is adjustable from 0.1 to 15 Hz. Using the pulsed electric field with 100 kV/m, 1 Hz and 80 ms pulse width to treat germinating mung beans and maize seeds,_the results indicated that the shoot length, root length and root number of mung beans and maize were significantly promoted. It was illustrated that the extremely low frequency high-voltage pulsed electric field based on potential fluctuations in plant had a significant biological effects. This paper laid the foundation for further study of biological effect on extremely low-frequency high-voltage pulsed electric field.%为开展极低频高压脉冲电场生物学效应的研究,设计了基于植物本征电位波动的极低频高压脉冲电场生物学效应仪,该系统可以产生幅值高压在6~20 kV、输出频率在0.1~15 Hz范围内数字式可调的极低频、宽脉宽、上升前沿陡的高压脉冲.用100 kV/m、1 Hz、80 ms脉宽的极低频高压脉冲电场处理萌发中的绿豆和玉米种子,发现极低频高压脉冲电场对绿豆和玉米种子的发芽和生长具有较强的促进作用,说明基于植物电位波动的极低频高压脉冲电场具有明显的生物学效应,研究结果可为极低频高压脉冲电场生物学效应的深入研究提供参考.

  9. 高压电场对钠钙硅酸盐玻璃风化性能的影响%Influences of the Imposed High Voltage Electric Field on the Weathering Properties of Soda-lime Silicate Glass

    Institute of Scientific and Technical Information of China (English)

    王洪成; 刘启明

    2009-01-01

    The soda-lime silicate float gIass is imposed to high voltage electrostatic field at the annealing temperature range of the ghss.The in fluences of the leakage current intensity,processing temperature and time on the ehnical stabilityofgLassan.der high-voltage electrostatic field are researched.The use of chemical titration analysis tested alkali of glass surface to research the hydrolytic resistance of glass.The glass samples accelerated weathering tests are carried out using constant temperature and humidity chamber,and the glass microscope morphology after weathering is observed by metallographic microscope XJZ-6.The experimental results show that when leakage current strength is lower than l50μA/cm~2,with increase of the high voltage elec trostatic field,the chemical stability(hydrolytic resistance)of the glass surface near the cahode surface(air side)increases,and litde change is found in that of the side(tin permeability surface).%在玻璃退火温度范围内,对钠钙硅酸盐平板玻璃施加高压电场.研究了高压电场下处理温度、时间、电场强度及泄露电流对玻璃化学稳定性的影响.利用化学滴定法测试了玻璃表面析碱量,研究了玻璃的耐水性.利用恒温恒湿箱进行了加速风化实验,采用XJZ-6型金相显微镜观察玻璃样品风化后的形貌.实验表明,泄露电流强度不大于150 μA/cm~2,高压电场提高正极附近玻璃表面(空气面)的化学稳定性,同时负极附近玻璃表面(渗锡面)的化学稳定性变化不大.

  10. 30 CFR 75.804 - Underground high-voltage cables.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground high-voltage cables. 75.804 Section... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.804 Underground high-voltage cables. (a) Underground high-voltage cables used in resistance...

  11. 30 CFR 77.810 - High-voltage equipment; grounding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage equipment; grounding. 77.810... COAL MINES Surface High-Voltage Distribution § 77.810 High-voltage equipment; grounding. Frames, supporting structures, and enclosures of stationary, portable, or mobile high-voltage equipment shall...

  12. High voltage source control on FODS

    Science.gov (United States)

    Patalakha, D. I.; Kalinin, A. Yu; Kulagin, N. V.

    2017-01-01

    The implementation of the high voltage power supply control system (HVPSCS) for experimental setup FODS (FOcusing Doublearmed Spectrometer) at accelerator U-70 of the Federal State Budgetary Institution State Research Center Of Russia Institute for High Energy Physics of the National Research Centre “Kurchatov Institute” (hereinafter referred to as IHEP) or for the test bench of the detector components is considered. The required set of hardware is defined and the appropriate software to operate HVPSCS is written in C/C++ codes. The date acquisition (DAQ) system [1] makes automatic control on HVPSCS for data taking run. It allows to get the dependence of appropriate detector parameters on the high voltage supply values and choose its optimal values for FODS detectors. The test run results of HVPSCS are presented.

  13. A prototype of a high-voltage platform for the KRION ion source

    Science.gov (United States)

    Alexandrov, V. S.; Donets, E. E.; Konnov, G. I.; Kosukhin, V. V.; Sidorova, V. O.; Sidorov, A. I.; Shvetsov, V. S.; Trubnikov, G. V.

    2014-09-01

    A high-voltage platform that has been developed for the KRION ion source is described. The platform design concept is explained. The calculations that have been performed of the influence of the design and materials on the source magnetic field make it possible to define a range of materials suitable for manufacturing the platform. The major components of the high-voltage platform, such as a high-voltage power supplier, and decoupling insulators of the high-voltage power source, and the main and supplementary platforms, are chosen and described. It is determined that, to exclude electric breakdowns and corona discharges, one should use an electrically shielded channel with a cryocooler and power supplies for the KRION-source coupling cables.

  14. Improved Lifetime High Voltage Switch Electrode.

    Science.gov (United States)

    2014-09-26

    capabilities of spark switches (e.g., saturable magnetic reactors, ignitions, and high power vacuum tubes), none has the combined high voltage, high...series impedance of the switch . Additionally, the eroded material may be deposited on internal insulators , thereby inducing pretriggering and erratic...of dry air, a typical spark switch insulating gas. -7- ENERGETIC IONS FROM ION IMPLANTER 0 0 0 0 -0 0 00000 0 0 oSUBSTRATE 0 - 0 o 0 SAMPLE= ’ 0• 0 U 0

  15. A high voltage programmable ramp generator

    Science.gov (United States)

    Upadhyay, J.; Joshi, M. J.; Deshpande, P. P.; Sharma, M. L.; Navathe, C. P.

    2008-05-01

    In this paper, a ramp generator with programmable slope is presented. It consists of a high voltage step generator, followed by integrator. The capacitor and inductor in the integrator are designed such that they can be varied by a microcontroller. This circuit generates two bipolar ramps with fastest speed <1ns and provides continuous speed variation from 6to30ns for a ramp of 500V. This is being developed as a part of automated streak camera for deflection of electron beam.

  16. High voltage testing for the MAJORANA DEMONSTRATOR

    Energy Technology Data Exchange (ETDEWEB)

    Abgrall, N. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Arnquist, I.J. [Pacific Northwest National Laboratory, Richland, WA (United States); Avignone, F.T. [Department of Physics and Astronomy, University of South Carolina, Columbia, SC (United States); Oak Ridge National Laboratory, Oak Ridge, TN (United States); Barabash, A.S. [National Research Center “Kurchatov Institute” Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Bertrand, F.E. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Bradley, A.W. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Brudanin, V. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Busch, M. [Department of Physics, Duke University, Durham, NC (United States); Triangle Universities Nuclear Laboratory, Durham, NC (United States); Buuck, M. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA (United States); Byram, D. [Department of Physics, University of South Dakota, Vermillion, SD (United States); Caldwell, A.S. [South Dakota School of Mines and Technology, Rapid City, SD (United States); Chan, Y-D. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Christofferson, C.D. [South Dakota School of Mines and Technology, Rapid City, SD (United States); Chu, P.-H. [Los Alamos National Laboratory, Los Alamos, NM (United States); Cuesta, C., E-mail: ccuesta@uw.edu [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA (United States); Detwiler, J.A.; Doe, P.J. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA (United States); and others

    2016-07-01

    The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in {sup 76}Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA DEMONSTRATOR. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA DEMONSTRATOR was characterized and the micro-discharge effects during the MAJORANA DEMONSTRATOR commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

  17. High voltage testing for the MAJORANA Demonstrator

    CERN Document Server

    Abgrall, N; Avignone, F T; Barabash, A S; Bertrand, F E; Bradley, A W; Brudanin, V; Busch, M; Buuck, M; Byram, D; Caldwell, A S; Chan, Y-D; Christofferson, C D; Chu, P -H; Cuesta, C; Detwiler, J A; Doe, P J; Dunagan, C; Efremenko, Yu; Ejiri, H; Elliott, S R; Fu, Z; Galindo-Uribarri, A; Giovanetti, G K; Goett, J; Green, M P; Gruszko, J; Guinn, I S; Guiseppe, V E; Henning, R; Hoppe, E W; Howard, S; Howe, M A; Jasinski, B R; Keeter, K J; Kidd, M F; Konovalov, S I; Kouzes, R T; LaFerriere, B D; Leon, J; Li, A; MacMullin, J; Martin, R D; Massarczyk, R; Meijer, S J; Mertens, S; Orrell, J L; O'Shaughnessy, C; Poon, A W P; Radford, D C; Rager, J; Rielage, K; Robertson, R G H; Romero-Romero, E; Shanks, B; Shirchenko, M; Snyder, N; Suriano, A M; Tedeschi, D; Thompson, A; Ton, K T; Trimble, J E; Varner, R L; Vasilyev, S; Vetter, K; Vorren, K; White, B R; Wilkerson, J F; Wiseman, C; Xu, W; Yakushev, E; Yu, C -H; Yumatov, V

    2016-01-01

    The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA Demonstrator. This eff?ect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including diff?erent improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA Demonstrator was characterized and the micro-discharge eff?ects during the MAJORANA Demonstrator commissioning phase were studied. A stable c...

  18. High voltage testing for the MAJORANA DEMONSTRATOR

    Science.gov (United States)

    Abgrall, N.; Arnquist, I. J.; Avignone, F. T.; Barabash, A. S.; Bertrand, F. E.; Bradley, A. W.; Brudanin, V.; Busch, M.; Buuck, M.; Byram, D.; Caldwell, A. S.; Chan, Y.-D.; Christofferson, C. D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Doe, P. J.; Dunagan, C.; Efremenko, Yu.; Ejiri, H.; Elliott, S. R.; Fu, Z.; Galindo-Uribarri, A.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Henning, R.; Hoppe, E. W.; Howard, S.; Howe, M. A.; Jasinski, B. R.; Keeter, K. J.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; LaFerriere, B. D.; Leon, J.; Li, A.; MacMullin, J.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Orrell, J. L.; O'Shaughnessy, C.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Rielage, K.; Robertson, R. G. H.; Romero-Romero, E.; Shanks, B.; Shirchenko, M.; Snyder, N.; Suriano, A. M.; Tedeschi, D.; Thompson, A.; Ton, K. T.; Trimble, J. E.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C.-H.; Yumatov, V.

    2016-07-01

    The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA DEMONSTRATOR. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA DEMONSTRATOR was characterized and the micro-discharge effects during the MAJORANA DEMONSTRATOR commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

  19. High voltage testing for the Majorana Demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Abgrall, N.; Arnquist, Isaac J.; Avignone, F. T.; Barabash, A.; Bertrand, F.; Bradley, A. W.; Brudanin, V.; Busch, Matthew; Buuck, M.; Byram, D.; Caldwell, A. S.; Chan, Yuen-Dat; Christofferson, C. D.; Chu, Pamela M.; Cuesta, C.; Detwiler, Jason A.; Doe, P. J.; Dunagan, C.; Efremenko, Yuri; Ejiri, H.; Elliott, S. R.; Fu, Z.; Galindo-Uribarri, A.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guinn, I.; Guiseppe, V. E.; Henning, R.; Hoppe, Eric W.; Howard, S.; Howe, M. A.; Jasinski, B. R.; Keeter, K.; Kidd, M. F.; Konovalov, S.; Kouzes, Richard T.; Laferriere, Brian D.; Leon, Jonathan D.; Li, Alexander D.; MacMullin, J.; Martin, R. D.; Massarcyk, R.; Meijer, S. J.; Mertens, S.; Orrell, John L.; O' Shaughnessy, C.; Poon, Alan W.; Radford, D. C.; Rager, J.; Rielage, Keith; Robertson, R. G. H.; Romero Romo, M.; Shanks, B.; Shirchenko, M.; Snyder, N.; Suriano, Anne-Marie E.; Tedeschi, D.; Thompson, Andrew; Ton, K. T.; Trimble, J. E.; Varner, R. L.; Vasilyev, Sergey; Vetter, Kai; Vorren, Kris R.; White, Brandon R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, Chang-Hong; Yumatov, V.

    2016-07-01

    The Majorana Collaboration is constructing theMajorana Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of theMajorana Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the Majorana Demonstrator was characterized and the micro-discharge effects during theMajorana Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

  20. Study of the interaction between space plasma and high voltage solar array

    OpenAIRE

    Iwasa, Minoru; TANAKA, KOJI; Sasaki, Susumu; ODAWARA, OSAMU; 岩佐 稔; 田中 孝治; 佐々木 進; 小田原 修

    2006-01-01

    We are studying the problems associated with high voltage power systems in space. Especially we are interested in the potential distribution of the solar array that is resistant to the electrical discharge. We have carried out experiment on the interaction between the space plasma and the high voltage solar array. An array of electrodes distributed on a dielectric material was used to simulate the inter-connectors of the solar array panel in space environment. One of major concerns in the usa...

  1. Study of the plasma interference with high voltage electrode array for space power application

    OpenAIRE

    Iwasa, Minoru; TANAKA, KOJI; Sasaki, Susumu; ODAWARA, OSAMU; 岩佐 稔; 田中 孝治; 佐々木 進; 小田原 修

    2005-01-01

    We are studying the problems associated with high voltage power systems in space. Especially we are interested in the potential distribution of the solar array that is resistant to the electrical discharge. We have carried out experiments on the interaction between the high voltage solar array and the ambient plasma. In the experiment, an array of electrodes distributed on the insulation panel was used to simulate the inter-connectors of the solar array. An electrode array without the insulat...

  2. Finite Element Based Optimal Design Approach for High Voltage Pulse Transformers

    CERN Document Server

    Aguglia, D; Viarouge, P; Cros, J

    2014-01-01

    This paper presents an optimal design methodology of monolithic high voltage pulse transformers based on the direct 2D FEA identification of the electrical equivalent circuit parameters. This method is applied to the preliminary optimal design of the monolithic high voltage pulse transformer for the future CLIC modulators under study at CERN. The feasibility of such a transformer with tight specifications is demonstrated. The predicted performances obtained with the direct 2D FEA optimization process is validated by 3D FEA simulation.

  3. 极低频高压脉冲电场对萌发玉米种子超弱发光的影响%Effect of Extremely Low Frequency High-voltage Pulsed Electric Field on Ultra-weak Luminescence of Corns during Germination

    Institute of Scientific and Technical Information of China (English)

    习岗; 刘锴; 杨运经; 高宇

    2013-01-01

    生物超弱发光是来自细胞的电磁信号,在揭示电磁生物学效应的机理研究中具有重要作用.为了研究极低频脉冲电场生物学效应及其机理,采用基于玉米细胞电位波动频率的1 Hz极低频高压脉冲电场处理萌发玉米种子,结果发现玉米种子的萌发过程明显加快,根长和芽长均有显著增长.对萌发种子的自发发光和延迟发光的测量结果显示,1 Hz极低频高压脉冲电场对萌发过程中玉米种子的自发发光和延迟发光积分强度都有明显的促进作用,表明1 Hz极低频高压脉冲电场加速了玉米种子萌发过程中的DNA合成和细胞代谢.%Biological ultra-weak luminescence is an electromagnetic signal from cells,which plays an important role in revealing the mechanism of electromagnetic biological effects.In order to study the biological effects and mechanism of extremely low frequency pulsed electric field,1 Hz extremely low frequency high-voltage pulsed electric field based on the potential fluctuation frequency of corn cells was used to treat the corns during germination.The results showed that the germination process of corns was accelerated obviously and both the shoot length and root length of germinating corns were significantly longer than the control.Through the measurement and analysis of spontaneous luminescence and delayed luminescence on corns during germination,it was found that the spontaneous luminescence and delayed luminescence integral intensity of germinating corn were significantly increased under the action of 1 Hz extremely low frequency high-voltage pulsed electric field,which indicated that this specific pulsed electric field promoted the DNA synthesis and cell metabolism of the corns during germination.The coupled resonance of pulsed electric field and cell electric field in corn seeds may be the cause of biological effects of the extremely low frequency high-voltage pulsed electric field.

  4. Design of Plasma Generator Driven by High-frequency High-voltage Power Supply

    Directory of Open Access Journals (Sweden)

    C. Yong-Nong

    2013-03-01

    Full Text Available In this research, a high-frequency high-voltage power supply designed for plasma generator is presented. The powersupply mainly consists of a series resonant converter with a high-frequency high-voltage boost transformer. Due to theindispensable high-voltage inheritance in the operation of plasma generator, the analysis of transformer needconsidering not only winding resistance, leakage inductance, magnetizing inductance, and core-loss resistance, butalso parasitic capacitance resulted from the insulation wrappings on the high-voltage side. This research exhibits asimple approach to measuring equivalent circuit parameters of the high-frequency, high-voltage transformer with straycapacitance being introduced into the conventional modeling. The proposed modeling scheme provides not only aprecise measurement procedure but also effective design information for series-load resonant converter. The plasmadischarging plate is designed as part of the electric circuit in the series load-resonant converter and the circuit modelof the plasma discharging plate is also conducted as well. Thus, the overall model of the high-voltage plasmagenerator is built and the designing procedures for appropriate selections of the corresponding resonant-circuitparameters can be established. Finally, a high-voltage plasma generator with 220V, 60Hz, and 1kW input, along witha 22 kHz and over 8kV output, is realized and implemented.

  5. Toe Tissue Transfer for Reconstruction of Damaged Digits due to Electrical Burns

    Directory of Open Access Journals (Sweden)

    Hyung-Do Kim

    2012-03-01

    Full Text Available Background Electrical burns are one of the most devastating types of injuries, and can becharacterized by the conduction of electric current through the deeper soft tissue such asvessels, nerves, muscles, and bones. For that reason, the extent of an electric burn is veryfrequently underestimated on initial impression.Methods From July 1999 to June 2006, we performed 15 cases of toe tissue transfer for thereconstruction of finger defects caused by electrical burns. We performed preoperative rangeof motion exercise, early excision, and coverage of the digital defect with toe tissue transfer.Results We obtained satisfactory results in both functional and aesthetic aspects in all 15cases without specific complications. Static two-point discrimination results in the transferredtoe cases ranged from 8 to 11 mm, with an average of 9.5 mm. The mean range of motionof the transferred toe was 20° to 36° in the distal interphalangeal joint, 16° to 45° in theproximal interphalangeal joint, and 15° to 35° in the metacarpophalangeal joint. All of thepatients were relatively satisfied with the function and appearance of their new digits.Conclusions The strategic management of electrical injury to the hands can be both challengingand complex. Because the optimal surgical method is free tissue transfer, maintenance ofvascular integrity among various physiological changes works as a determining factor for thepostoperative outcome following the reconstruction.

  6. Maintenance Optimization of High Voltage Substation Model

    Directory of Open Access Journals (Sweden)

    Jan Gala

    2008-01-01

    Full Text Available The real system from practice is selected for optimization purpose in this paper. We describe the real scheme of a high voltage (HV substation in different work states. Model scheme of the HV substation 22 kV is demonstrated within the paper. The scheme serves as input model scheme for the maintenance optimization. The input reliability and cost parameters of all components are given: the preventive and corrective maintenance costs, the actual maintenance period (being optimized, the failure rate and mean time to repair - MTTR.

  7. High voltage generator circuit with low power and high efficiency applied in EEPROM

    Institute of Scientific and Technical Information of China (English)

    Liu Yan; Zhang Shilin; Zhao Yiqiang

    2012-01-01

    This paper presents a low power and high efficiency high voltage generator circuit embedded in electrically erasable programmable read-only memory (EEPROM).The low power is minimized by a capacitance divider circuit and a regulator circuit using the controlling clock switch technique.The high efficiency is dependent on the zero threshold voltage (Vth) MOSFET and the charge transfer switch (CTS) charge pump.The proposed high voltage generator circuit has been implemented in a 0.35μm EEPROM CMOS process.Measured results show that the proposed high voltage generator circuit has a low power consumption of about 150.48 μW and a higher pumping efficiency (83.3%) than previously reported circuits.This high voltage generator circuit can also be widely used in low-power flash devices due to its high efficiency and low power dissipation.

  8. US and CT of the Liver after Electric Shock.

    Science.gov (United States)

    Sofić, Amela; Bešlić, Nermina; Efendić, Alma; Čarovac, Aladin; Šabanović, Jusuf; Jahić, Elma; Bukvić, Melika; Krakonja, Fikreta; Kupusović, Jana

    2016-01-01

    Liver injuries caused by high voltage electricity are rare and result in high mortality and morbidity. They are produced by the resistance to the passage of electrical current through the tissue, which creates heat that leads to coagulation necrosis and rupture of the cell membrane. We present a case of an electrical injury to the liver, diagnosed by ultrasound and CT in a 39-year-old man who presented with skin burns on his right hand and right hemiabdomen. Injuries occurred after the contact with 220 kV high voltage electricity.

  9. High voltage pulse generator. [Patent application

    Science.gov (United States)

    Fasching, G.E.

    1975-06-12

    An improved high-voltage pulse generator is described which is especially useful in ultrasonic testing of rock core samples. An N number of capacitors are charged in parallel to V volts and at the proper instance are coupled in series to produce a high-voltage pulse of N times V volts. Rapid switching of the capacitors from the paralleled charging configuration to the series discharging configuration is accomplished by using silicon-controlled rectifiers which are chain self-triggered following the initial triggering of the first rectifier connected between the first and second capacitors. A timing and triggering circuit is provided to properly synchronize triggering pulses to the first SCR at a time when the charging voltage is not being applied to the parallel-connected charging capacitors. The output voltage can be readily increased by adding additional charging networks. The circuit allows the peak level of the output to be easily varied over a wide range by using a variable autotransformer in the charging circuit.

  10. Safe epoxy encapsulant for high voltage magnetics

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, R.O.; Archer, W.E.

    1998-01-01

    This paper describes the use of Formula 456, an aliphatic amine cured epoxy for impregnating coils and high voltage transformers. Sandia has evaluated a number of MDA-free epoxy encapsulants which relied on either anhydride or other aromatic amine curing agents. The use of aliphatic amine curing agents was more recently evaluated and has resulted in the definition of Formula 456 resin. Methylene dianiline (MDA) has been used for more than 20 years as the curing agent for various epoxy formulations throughout the Department of Energy and much of industry. Sandia National Laboratories began the process of replacing MDA with other formulations because of regulations imposed by OSHA on the use of MDA. OSHA has regulated MDA because it is a suspect carcinogen. Typically the elimination of OSHA-regulated materials provides a rare opportunity to qualify new formulations in a range of demanding applications. It was important to take full advantage of that opportunity, although the associated materials qualification effort was costly. Small high voltage transformers are one of those demanding applications. The successful implementation of the new formulation for high reliability transformers will be described. The test results that demonstrate the parts are qualified for use in DOE weapon systems will be presented.

  11. Optimal planning of high voltage distribution substations

    Institute of Scientific and Technical Information of China (English)

    YU Yixin; YAN Xuefei; ZHANG Yongwu

    2007-01-01

    Aimed at solving the problem of optimal planning for high voltage distribution substations,an efficient method is put forward.The method divides the problem into two sub-problems:source locating and combinational optimization.The algorithm of allocating and locating alternatively (ALA) is widely used to deal with the source locating problem,but it is dependent on the initial location to a large degree.Thus,some modifications were made to the ALA algorithm,which could greatly improve the quality of solutions.In addition,considering the non-convex and nonconcave nature of the sub-problem of combinational optimization,the branch-and-bound technique was adopted to obtain or approximate a global optimal solution.To improve the efficiency of the branch-and-bound technique,some heuristic principles were proposed to cut those branches that may generate a global optimization solution with low probability.Examples show that the proposed algorithm meets the requirement of engineering and it is an effective approach to rapidly solve the problem of optimal planning for high voltage distribution substations.

  12. High-Voltage, Asymmetric-Waveform Generator

    Science.gov (United States)

    Beegle, Luther W.; Duong, Tuan A.; Duong, Vu A.; Kanik, Isik

    2008-01-01

    The shapes of waveforms generated by commercially available analytical separation devices, such as some types of mass spectrometers and differential mobility spectrometers are, in general, inadequate and result in resolution degradation in output spectra. A waveform generator was designed that would be able to circumvent these shortcomings. It is capable of generating an asymmetric waveform, having a peak amplitude as large as 2 kV and frequency of several megahertz, which can be applied to a capacitive load. In the original intended application, the capacitive load would consist of the drift plates in a differential-mobility spectrometer. The main advantage to be gained by developing the proposed generator is that the shape of the waveform is made nearly optimum for various analytical devices requiring asymmetric-waveform such as differential-mobility spectrometers. In addition, this waveform generator could easily be adjusted to modify the waveform in accordance with changed operational requirements for differential-mobility spectrometers. The capacitive nature of the load is an important consideration in the design of the proposed waveform generator. For example, the design provision for shaping the output waveform is based partly on the principle that (1) the potential (V) on a capacitor is given by V=q/C, where C is the capacitance and q is the charge stored in the capacitor; and, hence (2) the rate of increase or decrease of the potential is similarly proportional to the charging or discharging current. The proposed waveform generator would comprise four functional blocks: a sine-wave generator, a buffer, a voltage shifter, and a high-voltage switch (see Figure 1). The sine-wave generator would include a pair of operational amplifiers in a feedback configuration, the parameters of which would be chosen to obtain a sinusoidal timing signal of the desired frequency. The buffer would introduce a slight delay (approximately equal to 20 ns) but would otherwise

  13. Management Standardization for SF6 Gas in High-Voltage Electric Devices to Improve Equipment Operation Performance%规范高压电器中SF6气体的管理,提高设备运行效能

    Institute of Scientific and Technical Information of China (English)

    汪小红

    2014-01-01

    由于SF6气体具有良好绝缘、灭弧的特性,广泛应用于电力行业的高压电气设备中,因此SF6气体各个方面的管理能否达到使用要求、SF6高压电器能否达到应有的使用性能至关重要。做好SF6气体各个方面的管理可减少对环境的污染和破坏,避免给人们的身体健康带来不利影响。%With high insulation and arc extinguishing properties, SF6 gas has been widely applied in high voltage electric equipment, thus it is extremely important whether the comprehensive management of SF6 gas can meet requirement and SF6 high voltage devices can reach required operation performance. Good management of SF6 gas in every aspect can reduce pollution and impact to the environment and prevent harms to human health.

  14. Treatment Experience on 5 Cases of Electrical Burns, Electrical Contact with the Depth of the Burn%5例电击伤、电接触深度烧伤治疗体会

    Institute of Scientific and Technical Information of China (English)

    李辉武

    2013-01-01

      目的探讨电击伤、电接触深度烧伤后的治疗方法和临床体会。方法对我科收治的5例电击伤、电接触深度烧伤患者,采取早期切削痂植皮以及皮瓣移植治疗。结果电击伤患者普遍恢复较快,没有出现感染的情况,而且创面恢复也较快。结论电击伤、电接触深度烧伤患者,采取早期切削痂植皮以及皮瓣移植减轻患者的疼痛时间,而且安全性好,有利于患者的早日康复。%Objective To investigate the electrical burns, electrical contact treatment and clinical experience in deep burns. Methods 5 cases of electrical injury in our hospital, electrical contact depth of burn patients take the early cutting eschar and flap transplantation therapy. Results The patients with electrical burns patients’ generally faster recovery, no infection, and wound recovery were faster. Conclusion Electrical burns, electrical contact depth of burn patients take the early cutting eschar and flap graft to relieve the patient's pain, and security, and is conducive to the patient's speedy recovery.

  15. High Voltage Operation of Helical Pulseline Structures for Ion Acceleration

    CERN Document Server

    Waldron, William; Reginato, Lou

    2005-01-01

    The basic concept for the acceleration of heavy ions using a helical pulseline requires the launching of a high voltage traveling wave with a waveform determined by the beam transport physics in order to maintain stability and acceleration.* This waveform is applied to the front of the helix, creating over the region of the ion bunch a constant axial acceleration electric field that travels down the line in synchronism with the ions. Several methods of driving the helix have been considered. Presently, the best method of generating the waveform and also maintaining the high voltage integrity appears to be a transformer primary loosely coupled to the front of the helix, generating the desired waveform and achieving a voltage step-up from primary to secondary (the helix). This can reduce the drive voltage that must be brought into the helix enclosure through the feedthroughs by factors of 5 or more. The accelerating gradient is limited by the voltage holding of the vacuum insulator, and the material and helix g...

  16. Programmable high voltage power supply with regulation confined to the high voltage section

    Science.gov (United States)

    Castell, Karen D. (Inventor); Ruitberg, Arthur P. (Inventor)

    1994-01-01

    A high voltage power supply in a dc-dc converter configuration includes a pre-regulator which filters and regulates the dc input and drives an oscillator which applies, in turn, a low voltage ac signal to the low side of a step-up high voltage transformer. The high voltage side of the transformer drives a voltage multiplier which provides a stepped up dc voltage to an output filter. The output voltage is sensed by a feedback network which then controls a regulator. Both the input and output of the regulator are on the high voltage side, avoiding isolation problems. The regulator furnishes a portion of the drive to the voltage multiplier, avoiding having a regulator in series with the load with its attendant, relatively high power losses. This power supply is highly regulated, has low power consumption, a low parts count and may be manufactured at low cost. The power supply has a programmability feature that allows for the selection of a large range of output voltages.

  17. Plasma response to transient high voltage pulses

    Indian Academy of Sciences (India)

    S Kar; S Mukherjee

    2013-07-01

    This review reports on plasma response to transient high voltage pulses in a low pressure unmagnetized plasma. Mainly, the experiments are reviewed, when a disc electrode (metallic and dielectric) is biased pulsed negative or positive. The main aim is to review the electron loss in plasmas and particle balance during the negative pulse electrode biasing, when the applied pulse width is less than the ion plasma period. Though the applied pulse width is less than the ion plasma period, ion rarefaction waves are excited. The solitary electron holes are reviewed for positive pulsed bias to the electrode. Also the excitation of waves (solitary electron and ion holes) is reviewed for a metallic electrode covered by a dielectric material. The wave excitation during and after the pulse withdrawal, excitation and propagation characteristics of various electrostatic plasma waves are reviewed here.

  18. RICH High Voltages & PDF Analysis @ LHCb

    CERN Multimedia

    Fanchini, E

    2009-01-01

    In the LHCb experiment an important issue is the identification of the hadrons of the final states of the B mesons decays. Two RICH subdetectors are devoted to this task, and the Hybrid Photon Detectors (HPDs) are the photodetectors used to detect Cherenkov light. In this poster there is a description of how the very high voltage (-18 KV) supply stability used to power the HPDs is monitored. It is also presented the basics of a study which can be done with the first collision data: the analysis of the dimuons from the Drell-Yan process. This process is well known and the acceptance of the LHCb detector in terms of pseudorapidity will be very useful to improve the knowledge of the proton structure functions or, alternatively, try to estimate the luminosity from it.

  19. Planar multijunction high voltage solar cells

    Science.gov (United States)

    Evans, J. C., Jr.; Chai, A. T.; Goradia, C.

    1980-01-01

    Technical considerations, preliminary results, and fabrication details are discussed for a family of high-voltage planar multi-junction (PMJ) solar cells which combine the attractive features of planar cells with conventional or interdigitated back contacts and the vertical multijunction (VMJ) solar cell. The PMJ solar cell is internally divided into many voltage-generating regions, called unit cells, which are internally connected in series. The key to obtaining reasonable performance from this device was the separation of top surface field regions over each active unit cell. Using existing solar cell fabricating methods, output voltages in excess of 20 volts per linear centimeter are possible. Analysis of the new device is complex, and numerous geometries are being studied which should provide substantial benefits in both normal sunlight usage as well as with concentrators.

  20. An interleaved structure for a high-voltage planar transformer for a Travelling-wave Tube

    DEFF Research Database (Denmark)

    Zhao, Bin; Wang, Gang; Hurley, William G.;

    2016-01-01

    Fully interleaved structure can significantly reduce leakage inductance in transformers, However, it is hard to apply them into high-voltage applications due to the electric insulation. In this paper, a partially interleaved structure that is suitable for high-voltage high frequency applications...... is proposed to reduce leakage inductance and the insulation’s thickness is adjusted to optimize the electric isolation. In addition, the resistance and parasitic capacitance are investigated. With this method, a planar transformer used for a Travelling-Wave Tube Amplifier (TWTA) is designed. Calculations...

  1. Thoracic Duct Chylous Fistula Following Severe Electric Injury Combined with Sulfuric Acid Burns: A Case Report

    Science.gov (United States)

    Chang, Fei; Cheng, Dasheng; Qian, Mingyuan; Lu, Wei; Li, Huatao; Tang, Hongtai; Xia, Zhaofan

    2016-01-01

    Patient: Male, 32 Final Diagnosis: Thoracic duct chylous fistula Symptoms: Fistula Medication: — Clinical Procedure: A boneless muscle flap transplantatio Specialty: — Objective: Rare disease Background: As patients with thoracic duct injuries often suffer from severe local soft tissue defects, integrated surgical treatment is needed to achieve damage repair and wound closure. However, thoracic duct chylous fistula is rare in burn patients, although it typically involves severe soft tissue damage in the neck or chest. Case Report: A 32-year-old male patient fell after accidentally contacting an electric current (380 V) and knocked over a barrel of sulfuric acid. The sulfuric acid continuously poured onto his left neck and chest, causing combined electrical and sulfuric acid burn injuries to his anterior and posterior torso, and various parts of his limbs (25% of his total body surface area). During treatment, chylous fistula developed in the left clavicular region, which we diagnosed as thoracic duct chylous fistula. We used diet control, intravenous nutritional support, and continuous somatostatin to reduce the chylous fistula output, and hydrophilic silver ion-containing dressings for wound coverage. A boneless muscle flap was used to seal the left clavicular cavity, and, integrated, these led to resolution of the chylous fistula. Conclusions: Patients with severe electric or chemical burns in the neck or chest may be complicated with thoracic duct injuries. Although conservative treatment can control chylous fistula, wound cavity filling using a muscle flap is an effective approach for wound healing. PMID:27725628

  2. 高压电场对植物电特性的影响及促进光合作用的室内试验%Laboratory test on effects of high voltage electricity on electrostatic properties and promoting photosynthesis of plants

    Institute of Scientific and Technical Information of China (English)

    朱世秋; 张琳雪; 陈周; 徐艳; 王梦迪; 闫建河; 刘滨疆

    2016-01-01

    The photosynthesis and growth of plants are affected by many environment factors such as temperature, humidity, light, carbon dioxide (CO2)concentration, electrical field and magnetic field. In this paper the effects of high voltage electricity on the photosynthesis of plants are studied experimentally. Two boxes A and B which have positive or negative high voltage electricity are used. Plants can be grown in the garden pot with electricity, and electrical sources are fixed inside the bottom of the boxes. On the top of box a LED (light-emitting diode) bulb is settled as photosynthesis light. We use red light in these experiments. Another box C with no electricity is used for contrast research. First, the static-electrical parameters such as capacitance and current of living tissue of pepper tree leaves are measured while the plants are cultivated with high static-electricity in the boxes. Experimental results show no matter which positive or negative electricity is added on the plants, the capacitances at different points of leaves are lowed by about 0.01 nF, and the currents at different points of plants increase by 1.00-2.00μA. A high electrical field of several kilovolts per meter is created at the edges of leaves and branches while the plants are cultivated with high voltage electricity. In order to study how the photosynthesis of plants is affected by positive or negative electricity, the CO2 concentrations in the closed boxes A, B and C are measured during the same cultivation time, respectively. The results show that the CO2 concentration in the box B where plants are charged negatively decreases the most. In the experiment of green pineapple the decrease rate of CO2 concentration is 2μL/(L·min) in A box, 2.35μL/(L·min) in B box and 1.2μL/(L·min) in C box. In the experiment of golden diamond tree the decrease rate of CO2 concentration is 0.3μL/(L·min) in A box, 0.98μL/(L·min) in B box and 0.12μL/(L·min) in C box, respectively. In the experiments

  3. High Voltage Tests in the LUX-ZEPLIN System Test

    Science.gov (United States)

    Whitis, Thomas; Lux-Zeplin Collaboration

    2016-03-01

    The LUX-ZEPLIN (LZ) project is a dark matter direct detection experiment using liquid xenon. The detector is a time projection chamber (TPC) requiring the establishment of a large electric field inside of the detector in order to drift ionization electrons. Historically, many xenon TPC designs have been unable to reach their design fields due to light production and breakdown. The LZ System Test is scaled so that with a cathode voltage of -50 kV, it will have the fields that will be seen in the LZ detector at -100 kV. It will use a fully instrumented but scaled-down version of the LZ TPC design with a vessel set and gas system designed for quick turnaround, allowing for iterative modifications to the TPC prototype and instrumentation. This talk will present results from the high voltage tests performed during the first runs of the LZ System Test.

  4. High voltage direct current modelling in optimal power flows

    Energy Technology Data Exchange (ETDEWEB)

    Ambriz-Perez, H. [Comision Federal de Electricidad, Mexico, Unidad de Ingenieria Especializada, Rio Rodano No. 14 - Piso 10, Sala 1002, Col. Cuauhtemoc, C.P. 06598, Mexico, D.F. (Mexico); Acha, E. [Department of Electronics and Electrical Engineering, University of Glasgow, Glasgow G128LT, Scotland (United Kingdom); Fuerte-Esquivel, C.R. [Faculty of Electrical Engineering, Universidad Michoacana de San Nicolas de Hidalgo, Morelia 58030, Michoacan (Mexico)

    2008-03-15

    Two-terminal high voltage direct current (HVDC) transmission links are in operation throughout the world. They are key elements in electrical power networks; their representation is oversimplified or ignored in most power system studies. This is particularly the case in Optima Power Flow (OPF) studies. Hence, an OPF program has been extended to incorporate HVDC links, taking due account of overlapping and power transfer control characteristics. This is a new development in Newton Optimal Power Flows, where the converter equations are included directly in the matrix W. The method is indeed a unified one since the solution vector is extended to accommodate the DC variables. The HVDC link model correctly takes into account the relevant DC limit variables. The impact of HVDC links on OPF studies is illustrated by numeric examples, which includes a 5-node system, the AEP 14-node and a 166-node system. (author)

  5. Propylene based systems for high voltage cable insulation applications

    Energy Technology Data Exchange (ETDEWEB)

    Hosier, I L; Vaughan, A S; Swingler, S G [ECS, University of Southampton, Highfield, Southampton, SO17 1BJ (United Kingdom); Cozzarini, L, E-mail: ILH@ecs.soton.ac.u [DMRN, University of Trieste, Via Valerio 6A, 34127 Trieste (Italy)

    2009-08-01

    Crosslinked polyethylene (XLPE) remains the material of choice for extruded high voltage cables, possessing excellent thermo-mechanical and electrical properties. However, it is not easily recyclable posing questions as to its long term sustainability. Whilst both polyethylene and polypropylene are widely recycled and provide excellent dielectric properties, polypropylene has significantly better mechanical integrity at high temperatures than polyethylene. However, while isotactic polypropylene is too stiff at room temperature for incorporation into a cable system, previous studies by the authors have indicated that this limitation can be overcome by using a propylene-ethylene copolymer. Whilst these previous studies considered unrelated systems, the current study aims to quantify the usefulness of a series of related random propylene-ethylene co-polymers and assesses their potential for replacing XLPE.

  6. High voltage magnetic pulse generation using capacitor discharge technique

    Directory of Open Access Journals (Sweden)

    M. Rezal

    2014-12-01

    Full Text Available A high voltage magnetic pulse is designed by applying an electrical pulse to the coil. Capacitor banks are developed to generate the pulse current. Switching circuit consisting of Double Pole Double Throw (DPDT switches, thyristor, and triggering circuit is developed and tested. The coil current is measured using a Hall-effect current sensor. The magnetic pulse generated is measured and tabulated in a graph. Simulation using Finite Element Method Magnetics (FEMM is done to compare the results obtained between experiment and simulation. Results show that increasing the capacitance of the capacitor bank will increase the output voltage. This technology can be applied to areas such as medical equipment, measurement instrument, and military equipment.

  7. Environmental and biotechnological applications of high-voltage pulsed discharges in water

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Masayuki [Department of Chemical and Environmental Engineering, Gunma University 1-5-1 Tenjin, Kiryu, Gunma 376-8515 (Japan)], E-mail: mxsato@cee.gunma-u.ac.jp

    2008-05-01

    A high-voltage pulse has wide application in fields such as chemistry, physics and biology and their combinations. The high-voltage pulse forms two kinds of physical processes in water, namely (a) a pulsed electric field (PEF) in the parallel electrode configuration and (b) plasma generation by a pulsed discharge in the water phase with a concentrated electric field. The PEF can be used for inactivation of bacteria in liquid foods as a non-thermal process, and the underwater plasma is applicable not only for the decomposition of organic materials in water but also for biological treatment of wastewater. These discharge states are controlled mainly by the applied pulse voltage and the electrode shape. Some examples of environmental and biotechnological applications of a high-voltage pulse are reviewed.

  8. Plasma Interaction with International Space Station High Voltage Solar Arrays

    Science.gov (United States)

    Heard, John W.

    2002-01-01

    The International Space Station (ISS) is presently being assembled in low-earth orbit (LEO) operating high voltage solar arrays (-160 V max, -140 V typical with respect to the ambient atmosphere). At the station's present altitude, there exists substantial ambient plasma that can interact with the solar arrays. The biasing of an object to an electric potential immersed in plasma creates a plasma "sheath" or non-equilibrium plasma around the object to mask out the electric fields. A positively biased object can collect electrons from the plasma sheath and the sheath will draw a current from the surrounding plasma. This parasitic current can enter the solar cells and effectively "short out" the potential across the cells, reducing the power that can be generated by the panels. Predictions of collected current based on previous high voltage experiments (SAMPIE (Solar Array Module Plasma Interactions Experiment), PASP+ (Photovoltaic Array Space Power) were on the order of amperes of current. However, present measurements of parasitic current are on the order of several milliamperes, and the current collection mainly occurs during an "eclipse exit" event, i.e., when the space station comes out of darkness. This collection also has a time scale, t approx. 1000 s, that is much slower than any known plasma interaction time scales. The reason for the discrepancy between predictions and present electron collection is not understood and is under investigation by the PCU (Plasma Contactor Unit) "Tiger" team. This paper will examine the potential structure within and around the solar arrays, and the possible causes and reasons for the electron collection of the array.

  9. Biological and Agricultural Studies on Application of Discharge Plasma and Electromagnetic Fields 4. Destruction of Weeds by High Voltage Discharge

    Science.gov (United States)

    Mizuno, Akira

    In an attempt to replace chemicals for weed control, high voltage spark discharge has been applied. With the application of high voltage, discharge takes place, and current flows through the stem and root. Microscopic observation indicates that cells are damaged. The electrical resistance of the damage plant’s stems and roots decreased significantly. Several different types of apparatus were constructed, and field test results show the effectiveness of electrical discharge for weed control.

  10. [Pulmonary lesion in electric injury: report of a case].

    Science.gov (United States)

    Goldenberg, D C; Bringel, R W; Fontana, C; Teixeira, T L; de Almeida, P C; de Faria, J C; Ferreira, M C

    1996-01-01

    Major electrical injuries constitute approximately 5% of all admissions to Burn Units. Visceral complications are associated with a high mortality rate. The most common visceral lesions associated to electric burns are cardiac lesions. Pulmonary compromise is rare, if compared to inhalation injuries in termical burns. Although, when the entry or exit ports are the toracic wall, pleural effusion, hemotorax and pneumonitis may occur. A rare case of high-voltage electrical injury with massive pulmonary lesion is presented, regarding to clinical course and roentgenographic patterns.

  11. 浅析高压电动机振动值与电能质量之间的联系%Analysis of the relationship between high voltage motor vibration and electric power quality

    Institute of Scientific and Technical Information of China (English)

    冀杰

    2011-01-01

    In order to locate the reason of abnormal motor vibration when the motor is runing, the electric power quality analysis was investigated.After an academic explanation and analysis of actual testing data, the primary conclusion that abnormal motor vibration was caused by the unbalanced incoming current was established.Lastly through simple calculation and comparison, the experimental results show that the unbalanced electric source voltage is one of the direct factor leading the abnormal motor vibration.%为探讨高压电动机在运行时出现的电机本体振动值偏高问题的原因,将电能质量技术应用到电动机振动分析中.通过理论简析和实测数据建立了电流不平衡性与电机振动值之间的关系,提出电动机进线电流不平衡是迫使其振动值偏大的重要原因.实测数据分析结果表明,外电源进线电压不平衡是引起电机振动值偏大的直接原因之一.

  12. Design of an Actinide Burning, Lead-Bismuth Cooled Reactor That Produces Low Cost Electricity

    Energy Technology Data Exchange (ETDEWEB)

    C. Davis; S. Herring; P. MacDonald; K. McCarthy; V. Shah; K. Weaver (INEEL); J. Buongiorno; R. Ballinger; K. Doyoung; M. Driscoll; P. Hejzler; M. Kazimi; N. Todreas (MIT)

    1999-07-01

    The purpose of this project is to investigate the suitability of lead-bismuth cooled fast reactors for producing low-cost electricity as well as for actinide burning. The goal is to identify and analyze the key technical issues in core neutronics, materials, thermal-hydraulics, fuels, and economics associated with the development of this reactor concept. The choice of lead-bismuth for the reactor coolant is an actinide burning fast reactor offers enhanced safety and reliability. The advantages of lead-bismuth over sodium as a coolant are related to the following material characteristics: chemical inertness with air and water; higher atomic number; lower vapor pressure at operating temperatures; and higher boiling temperature. Given the status of the field, it was agreed that the focus of this investigation in the first two years will be on the assessment of approaches to optimize core and plant arrangements in order to provide maximum safety and economic potential in this type of reactor.

  13. Study of protection devices against the effects of electric discharges inside a very high voltage generator: the Vivitron accelerator; Etude de dispositifs de protection contre les effets des decharges electriques au sein d`un generateur de tres haute tension: l`accelerateur Vivitron

    Energy Technology Data Exchange (ETDEWEB)

    Nolot, E.

    1996-10-31

    The Vivitron tandem is a large electrostatic accelerator comprising a Van de Graaff generator designed to reach terminal voltages of around 30 MV. The machine is limited at rather lower nominal voltages (about 20 MV) due to the sensitivity of the insulating column structure to transient overvoltages. These are induced by electrical discharges in compressed SF{sub 6}. This thesis first aims at analysing the fundamental reasons of electrical discharges in order to limit the probability of their occurrence. Then we simulate the transient overvoltages induced and present some improvements which may lead to a stable behaviour of the Vivitron at nominal voltages higher than 20 MV. Initially we deduce discharge onset voltages and actual breakdown field limitations in the different gap geometries from analysis of possible breakdown mechanisms in compressed SF{sub 6}. In a second part, some electrical characteristics of the insulating column structure are measured at high voltage. Fast rising oscillating waves induced by sparking in the Vivitron, along with the associated energies,are determined in the third part. The last part deals with new surge protections of the insulating column structure. Spark gaps with precise onset voltage and optimized shielding electrodes are discussed. ZnO-based varistors designed for operation at very high fields have also been developed in order to reduce transient overvoltage values. (author). 122 refs.

  14. Analysis of the Interphase on Carbon Black Formed in High Voltage Batteries

    DEFF Research Database (Denmark)

    Younesi, Reza; Christiansen, Ane Sælland; Scipioni, Roberto

    2015-01-01

    Carbon black (CB) additives commonly used to increase the electrical conductivity of electrodes in Li-ion batteries are generally believed to be electrochemically inert additives in cathodes. Decomposition of electrolyte in the surface region of CB in Li-ion cells at high voltages up to 4.9 V...

  15. Using Expert Systems in Evaluation of the State of High Voltage Machine Insulation Systems

    Directory of Open Access Journals (Sweden)

    K. Záliš

    2000-01-01

    Full Text Available Expert systems are used for evaluating the actual state and future behavior of insulating systems of high voltage electrical machines and equipment. Several rule-based expert systems have been developed in cooperation with top diagnostic workplaces in the Czech Republic for this purpose. The IZOLEX expert system evaluates diagnostic measurement data from commonly used offline diagnostic methods for the diagnostic of high voltage insulation of rotating machines, non-rotating machines and insulating oils. The CVEX expert system evaluates the discharge activity on high voltage electrical machines and equipment by means of an off-line measurement. The CVEXON expert system is for evaluating the discharge activity by on-line measurement, and the ALTONEX expert system is the expert system for on-line monitoring of rotating machines. These developed expert systems are also used for educating students (in bachelor, master and post-graduate studies and in courses which are organized for practicing engineers and technicians and for specialists in the electrical power engineering branch. A complex project has recently been set up to evaluate the measurement of partial discharges. Two parallel expert systems for evaluating partial dischatge activity on high voltage electrical machines will work at the same time in this complex evaluating system.

  16. Understanding and Improving High Voltage Vacuum Insulators for Microsecond Pulses

    Energy Technology Data Exchange (ETDEWEB)

    Javedani, J B; Goerz, D A; Houck, T L; Lauer, E J; Speer, R D; Tully, L K; Vogtlin, G E; White, A D

    2007-03-05

    High voltage insulation is one of the main areas of pulsed power research and development, and dielectric breakdown is usually the limiting factor in attaining the highest possible performance in pulsed power devices. For many applications the delivery of pulsed power into a vacuum region is the most critical aspect of operation. The surface of an insulator exposed to vacuum can fail electrically at an applied field more than an order or magnitude below the bulk dielectric strength of the insulator. This mode of breakdown, called surface flashover, imposes serious limitations on the power flow into a vacuum region. This is especially troublesome for applications where high voltage conditioning of the insulator and electrodes is not practical and for applications where relatively long pulses, on the order of several microseconds, are required. The goal of this project is to establish a sound fundamental understanding of the mechanisms that lead to surface flashover, and then evaluate the most promising techniques to improve vacuum insulators and enable high voltage operation at stress levels near the intrinsic bulk breakdown limits of the material. The approach we proposed and followed was to develop this understanding through a combination of theoretical and computation methods coupled with experiments to validate and quantify expected behaviors. In this report we summarize our modeling and simulation efforts, theoretical studies, and experimental investigations. The computational work began by exploring the limits of commercially available codes and demonstrating methods to examine field enhancements and defect mechanisms at microscopic levels. Plasma simulations with particle codes used in conjunction with circuit models of the experimental apparatus enabled comparisons with experimental measurements. The large scale plasma (LSP) particle-in-cell (PIC) code was run on multiprocessor platforms and used to simulate expanding plasma conditions in vacuum gap regions

  17. Modular high voltage power supply for chemical analysis

    Science.gov (United States)

    Stamps, James F.; Yee, Daniel D.

    2008-07-15

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  18. High Voltage, Fast-Switching Module for Active Control of Magnetic Fields and Edge Plasma Currents

    Science.gov (United States)

    Ziemba, Timothy; Miller, Kenneth; Prager, James; Slobodov, Ilia

    2016-10-01

    Fast, reliable, real-time control of plasma is critical to the success of magnetic fusion science. High voltage and current supplies are needed to mitigate instabilities in all experiments as well as disruption events in large scale tokamaks for steady-state operation. Silicon carbide (SiC) MOSFETs offer many advantages over IGBTs including lower drive energy requirements, lower conduction and switching losses, and higher switching frequency capabilities; however, these devices are limited to 1.2-1.7 kV devices. As fusion enters the long-pulse and burning plasma eras, efficiency of power switching will be important. Eagle Harbor Technologies (EHT), Inc. developing a high voltage SiC MOSFET module that operates at 10 kV. This switch module utilizes EHT gate drive technology, which has demonstrated the ability to increase SiC MOSFET switching efficiency. The module will allow more rapid development of high voltage switching power supplies at lower cost necessary for the next generation of fast plasma feedback and control. EHT is partnering with the High Beta Tokamak group at Columbia to develop detailed high voltage module specifications, to ensure that the final product meets the needs of the fusion science community.

  19. Investigation Of The High-Voltage Discharge On The Surface Of Gas-Liquid System

    Science.gov (United States)

    Nguyen-Kuok, Shi; Morgunov, Aleksandr; Malakhov, Yury; Korotkikh, Ivan

    2016-09-01

    This paper describes an experimental setup for study of physical processes in the high-voltage discharge on the surface of gas-liquid system at atmospheric pressure. Measurements of electrical and optical characteristics of the high-voltage discharge in gas, at the surface of the gas-liquid system and in the electrolyte are obtained. The parameters of the high-voltage discharge and the conditions for its stable operation are presented. Investigations with various electrolytes and cathode assemblies of various materials and sizes were carried out. The installation can be used for the processing and recycling of industrial and chemical liquid waste. Professor of Laboratory of Plasma Physics, National Research University MPEI, Krasnokazarmennya Str.14, 111250, Moscow, Russia.

  20. High voltage transmission lines studies with the use of artificial intelligence

    Energy Technology Data Exchange (ETDEWEB)

    Ekonomou, L. [A.S.PE.T.E. - School of Pedagogical and Technological Education, Department of Electrical Engineering Educators, N. Heraklion, 141 21 Athens (Greece)

    2009-12-15

    The paper presents an alternative approach for the studies of high voltage transmission lines based on artificial intelligence and more specifically artificial neural networks (ANNs). In contrast to the existing conventional-analytical techniques and simulations which are using in the calculations empirical and/or approximating equations, this approach is based only on actual field data and actual measurements. The proposed approach is applied on high voltage transmission lines in order to calculate the lightning outages, on grounding systems in order to assess the grounding resistance and on high voltage transmission lines' polluted insulators in order to estimate the critical flashover voltage. The obtained results are very close to the actual ones for all three case studies, something which clearly implies that the ANN approach is well working and has an acceptable accuracy, constituting an additional tool of electric engineers. (author)

  1. Evaluation of high temperature dielectric films for high voltage power electronic applications

    Science.gov (United States)

    Suthar, J. L.; Laghari, J. R.

    1992-01-01

    Three high temperature films, polyimide, Teflon perfluoroalkoxy and poly-P-xylene, were evaluated for possible use in high voltage power electronic applications, such as in high energy density capacitors, cables and microelectronic circuits. The dielectric properties, including permittivity and dielectric loss, were obtained in the frequency range of 50 Hz to 100 kHz at temperatures up to 200 C. The dielectric strengths at 60 Hz were determined as a function of temperature to 250 C. Confocal laser microscopy was performed to diagnose for voids and microimperfections within the film structure. The results obtained indicate that all films evaluated are capable of maintaining their high voltage properties, with minimal degradation, at temperatures up to 200 C. However, above 200 C, they lose some of their electrical properties. These films may therefore become viable candidates for high voltage power electronic applications at high temperatures.

  2. CFD Simulation of Transonic Flow in High-Voltage Circuit Breaker

    Directory of Open Access Journals (Sweden)

    Xiangyang Ye

    2012-01-01

    Full Text Available A high-voltage circuit breaker is an indispensable piece of equipment in the electric transmission and distribution systems. Transonic flow typically occurs inside breaking chamber during the current interruption, which determines the insulating characteristics of gas. Therefore, accurate compressible flow simulations are required to improve the prediction of the breakdown voltages in various test duties of high-voltage circuit breakers. In this work, investigation of the impact of the solvers on the prediction capability of the breakdown voltages in capacitive switching is presented. For this purpose, a number of compressible nozzle flow validation cases have been presented. The investigation is then further extended for a real high-voltage circuit breaker geometry. The correlation between the flow prediction accuracy and the breakdown voltage prediction capability is identified.

  3. Assessment of electrical burn injury using structured illumination in an in-vivo electrical injury model

    Science.gov (United States)

    Nguyen, Thu T. A.; Basiri, Ali; Shupp, J. W.; Moffatt, L. T.; Jordan, M. H.; Jeng, J. C.; Leto, E.; Ramella-Roman, J. C.

    2011-03-01

    Electrical injury is a devastating and hard to treat clinical lesion. Fully understanding the pathophysiology of electrical trauma is still a challenge for clinicians and scientists. Further elucidating the natural history of this form of tissue injury could be helpful in improving limb salvage and offering stage-appropriate therapy. Multi-spectral imaging technique is a non-invasive technology that can be used to determine optical properties of tissues in and adjacent to injury. Images at different wavelengths can provide essential information related to the pathophysiological condition of the tissue. To promote the applicability of this technique in medical diagnosis, we built a complete experimental model of electrical injury. In this model, electrical injuries were created by a reliable high-tension shock system at preset voltage or current. A thermal camera recorded the change of skin temperature during the electrical shock. Then, a high-resolution spectral imaging system based on structured illumination was used to capture images for post analysis to extrapolate optical properties of the tissue. To test accuracy, this imaging system was calibrated by using a set of epoxy phantoms with known optical properties. In this paper, the results of experiments conducted on rats and discussions on the systemic changes in tissue optical properties before and after electrical shock are presented.

  4. High Voltage Dielectrophoretic and Magnetophoretic Hybrid Integrated Circuit / Microfluidic Chip

    Science.gov (United States)

    Issadore, David; Franke, Thomas; Brown, Keith A.; Hunt, Thomas P.; Westervelt, Robert M.

    2010-01-01

    A hybrid integrated circuit (IC) / microfluidic chip is presented that independently and simultaneously traps and moves microscopic objects suspended in fluid using both electric and magnetic fields. This hybrid chip controls the location of dielectric objects, such as living cells and drops of fluid, on a 60 × 61 array of pixels that are 30 × 38 μm2 in size, each of which can be individually addressed with a 50 V peak-to-peak, DC to 10 MHz radio frequency voltage. These high voltage pixels produce electric fields above the chip’s surface with a magnitude , resulting in strong dielectrophoresis (DEP) forces . Underneath the array of DEP pixels there is a magnetic matrix that consists of two perpendicular sets of 60 metal wires running across the chip. Each wire can be sourced with 120 mA to trap and move magnetically susceptible objects using magnetophoresis (MP). The DEP pixel array and magnetic matrix can be used simultaneously to apply forces to microscopic objects, such as living cells or lipid vesicles, that are tagged with magnetic nanoparticles. The capabilities of the hybrid IC / microfluidic chip demonstrated in this paper provide important building blocks for a platform for biological and chemical applications. PMID:20625468

  5. Dielectric insulation and high-voltage issues

    CERN Document Server

    Tommasini, D

    2010-01-01

    Electrical faults are in most cases dramatic events for magnets, due to the large stored energy which is potentially available to be dissipated at the fault location. After a reminder of the principles of electrostatics in Section 1, the basic mechanisms of conduction and breakdown in dielectrics are summarized in Section 2. Section 3 introduces the types and function of the electrical insulation in magnets, and Section 4 its relevant failure mechanisms. Section 5 deals with ageing and, finally, Section 6 gives some principles for testing. Though the School specifically dealt with warm magnets, for completeness some principles of dielectric insulation for superconducting accelerator magnets are briefly summarized in a dedicated appendix.

  6. A High-Voltage Level Tolerant Transistor Circuit

    NARCIS (Netherlands)

    Annema, Anne Johan; Geelen, Godefridus Johannes Gertrudis Maria

    2001-01-01

    A high-voltage level tolerant transistor circuit, comprising a plurality of cascoded transistors, including a first transistor (T1) operatively connected to a high-voltage level node (3) and a second transistor (T2) operatively connected to a low-voltage level node (2). The first transistor (T1) con

  7. Electrical conductivity of a methane-air burning plasma under the action of weak electric fields

    Science.gov (United States)

    Colonna, G.; Pietanza, L. D.; D'Angola, A.; Laricchiuta, A.; Di Vita, A.

    2017-02-01

    This paper focuses on the calculation of the electrical conductivity of a methane-air flame in the presence of weak electric fields, solving the Boltzmann equation for free electrons self-consistently coupled with chemical kinetics. The chemical model GRI-Mech 3.0 has been completed with chemi-ionization reactions to model ionization in the absence of fields, and a database of cross sections for electron-impact-induced processes to account for reactions and transitions activated in the flame during discharge. The dependence of plasma properties on the frequency of an oscillating field has been studied under different pressure and gas temperature conditions. Fitting expressions of the electrical conductivity as a function of gas temperature and methane consumption are provided for different operational conditions in the Ansaldo Energia burner.

  8. Optically initiated silicon carbide high voltage switch

    Science.gov (United States)

    Caporaso, George J.; Sampayan, Stephen E.; Sullivan, James S.; Sanders; David M.

    2011-02-22

    An improved photoconductive switch having a SiC or other wide band gap substrate material, such as GaAs and field-grading liners composed of preferably SiN formed on the substrate adjacent the electrode perimeters or adjacent the substrate perimeters for grading the electric fields.

  9. Multiple High Voltage Pulse Stressing of Polymer Thick Film Resistors

    Directory of Open Access Journals (Sweden)

    Busi Rambabu

    2014-01-01

    Full Text Available The purpose of this paper is to study high voltage interactions in polymer thick film resistors, namely, polyvinyl chloride- (PVC- graphite thick film resistors, and their applications in universal trimming of these resistors. High voltages in the form of impulses for various pulse durations and with different amplitudes have been applied to polymer thick film resistors and we observed the variation of resistance of these resistors with high voltages. It has been found that the resistance of polymer thick film resistors decreases in the case of higher resistivity materials and the resistance of polymer thick film resistor increases in the case of lower resistivity materials when high voltage impulses are applied to them. It has been also found that multiple high voltage pulse (MHVP stressing can be used to trim the polymer thick film resistors either upwards or downwards.

  10. Analytical calculations of anode plasma position in high-voltage discharge range in case of auxiliary discharge firing

    OpenAIRE

    Melnyk, Igor V.; Tugay, S. B.

    2012-01-01

    We consider the mathematical model of triode high-voltage glow discharge range in case of auxiliary discharge firing. On a basis of analysis of elementary processes of charged particles interaction in a discharge range we obtain analytical relation, which allows to obtain the anode plasma position with regard to the cathode. Obtained results can be used for analysis of analysis of energy balance in a discharge range and self-maintained electron-ion optics of high voltage glow discharge electr...

  11. High-Voltage Solid Polymer Batteries for Electric Drive Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Eitouni, Hany; Yang, Jin; Pratt, Russell; Wang, Xiao; Grape, Ulrik

    2014-09-29

    The purpose of this project was for Seeo to develop a high energy lithium based technology with targets of over 500 Wh/l and 325 Wh/kg. Seeo would leverage the work already achieved with its unique proprietary solid polymer DryLyteTM technology in cells which had a specific energy density of 220 Wh/kg. The development work was focused on establishing a dual electrolyte system, coated cathode particle techniques, various types of additives, and different conductive salts. The program had a duration of three years, with Seeo delivering the final cells at the end of 2014 for evaluation by a DOE laboratory.

  12. A diagnostic system for high-voltage electrical components

    Energy Technology Data Exchange (ETDEWEB)

    Masetti, C.

    1988-10-01

    This paper presents an example, indicating system logic and architecture, of a centralized diagnostic system for a modern substation. Detail are provided of the part relevant to the most important functions and operations required: measurements and transduction; local signal transmission, data acquisition and possible display; remote signal transmission; central processing, interpretation and decision-making. The diagnostic system in this case was designed to control a number of power transformers of a utility or large industrial user operating on a regional scale: the example can be extended in a modular way to include also the monitoring of other components (GIS, circuit breakers, arresters, etc.), or of more stations of a larger national network. The diagnostic system envisaged is thus flexible, with respect to the different functions required to solve, and modular, so that it can be integrated and expanded gradually as one pleases.

  13. Proximity effects of high voltage electric power transmission lines on ...

    African Journals Online (AJOL)

    Yomi

    2010-08-18

    Aug 18, 2010 ... were observed on seed germination, seedling growth, agronomic traits and seed yield .... Stimulation of regeneration by magnetic field in soybean (Glycine max L. Merrill) tissue cultures, J. Cell Mol. Biol. 2: 113-119. Balouchi ...

  14. On-line Monitoring System based on Vibration Signal of High Voltage Circuit Breaker

    Directory of Open Access Journals (Sweden)

    Chao Fu

    2014-04-01

    Full Text Available High voltage circuit breaker is one of the most important switch apparatus in electrical power system. It play a role in the switch control, which can be used to switch the operating mode during normal operation (the equipment run or quit. In order to ensure the normal operation of the grid, it can be removed quickly when a malfunction on the device or circuit. Real-time online monitoring of high voltage circuit breaker can understand the running status, master the operation characteristics and its tend of development. As early as possible find the potential faults then take preventive measures timely, so as to ensure the reliable operation of power system. Online monitoring of high voltage circuit breakers can reduce the premature or unnecessary maintenance and maintenance cost, improve pertinence of the maintenance firstly. Secondly, it can improve the life of the switching device and improve the reliability of electric power system significantly. In this paper, on-line monitoring system based on vibration signal of high voltage circuit breaker is presented

  15. Current Analysis and Modification Measures of High Voltage Synchronous Motor Shaft%高压同步电机轴电流分析及改装措施

    Institute of Scientific and Technical Information of China (English)

    侯江继

    2014-01-01

    通过现场高压同步电机与焦炉气压缩机轴瓦烧损的故障处理,分析了轴电流产生的原因及电机和焦炉气压缩机滑动轴瓦的危害,并提出防止电机产生轴电流电腐蚀的有效措施。%Through the fault processing of the burned field high voltage synchronous motor and coke oven gas compressor, this paper analyzes the cause of the shaft current and its hazard on motor and coke oven gas compressor sliding bearing, and puts forward some effective measures to prevent the motor shaft current electric corrosion.

  16. LED-Based High-Voltage Lines Warning System

    Directory of Open Access Journals (Sweden)

    Eldar MUSA

    2013-04-01

    Full Text Available LED-based system, running with the current of high-voltage lines and converting the current flowing through the line into the light by using a toroid transformer, has been developed. The transformer’s primary winding is constituted by the high voltage power line. Toroidal core consists of two equal parts and the secondary windings are evenly placed on these two parts. The system is mounted on the high-voltage lines as a clamp. The secondary winding ends are connected in series by the connector on the clamp. LEDs are supplied by the voltage at the ends of secondary. Current flowing through highvoltage transmission lines is converted to voltage by the toroidal transformer and the light emitting LEDs are supplied with this voltage. The theory of the conversion of the current flowing through the line into the light is given. The system, running with the current of the line and converting the current into the light, has been developed. System has many application areas such as warning high voltage lines (warning winches to not hinder the high-voltage lines when working under the lines, warning planes to not touch the high-voltage lines, remote measurement of high-voltage line currents, and local illumination of the line area

  17. New perspectives in vacuum high voltage insulation. II. Gas desorption

    CERN Document Server

    Diamond, W T

    1998-01-01

    An examination has been made of gas desorption from unbaked electrodes of copper, niobium, aluminum, and titanium subjected to high voltage in vacuum. It has been shown that the gas is composed of water vapor, carbon monoxide, and carbon dioxide, the usual components of vacuum outgassing, plus an increased yield of hydrogen and light hydrocarbons. The gas desorption was driven by anode conditioning as the voltage was increased between the electrodes. The gas is often desorbed as microdischarges-pulses of a few to hundreds of microseconds-and less frequently in a more continuous manner without the obvious pulsed structure characteristic of microdischarge activity. The quantity of gas released was equivalent to many monolayers and consisted mostly of neutral molecules with an ionic component of a few percent. A very significant observation was that the gas desorption was more dependent on the total voltage between the electrodes than on the electric field. It was not triggered by field-emitted electrons but oft...

  18. High Voltage Breakdown Levels in Various EPC Potting Materials

    Science.gov (United States)

    Komm, David S.

    2006-01-01

    This viewgraph presentation reviews exploration activities at JPL into various potting materials. Since high power space-borne microwave transmitters invariably use a vacuum tube as a final power amplifier, and this tube requires high electrode voltages for operation. The associated high voltage insulation typically represents a significant fraction of the mass of the transmitter. Since mass is always a premium resource on board spacecraft, we have been investigating materials with the potential to reduce the mass required for our applications here at JPL. This paper describes electrical breakdown results obtained with various potting materials. Conathane EN-11 (polyurethane) is the traditional HVPS encapsulant at JPL, but due to temperature limitations and durability issues it was deemed inappropriate for the particular application (i.e., CloudSat radar). The choices for the best available materials were epoxies, or silicones. Epoxies are too rigid, and were deemed inadvisable. Two silicones were further investigated (i.e.,ASTM E595- 93e2: GE RTV566(R) and Dow Corning 93-500X(R), another compound was considered (i.e., DC material, Sylgard 184(R)). "Loading" (adding filler materials) the potting compound will frequently alter the final material properties. Powdered alumina and borosilicate glass known as "microballoons" were investigated as possible loading materials. The testing of the materials is described. Each of the two loading materials offers advantages and disadvantages. The advantages and disadvantages are described.

  19. Modeling of High-voltage Breakdown in Helium

    Science.gov (United States)

    Xu, Liang; Khrabrov, Alexander; Kaganovich, Igor; Sommerer, Timothy

    2016-09-01

    We investigate the breakdown in extremely high reduced electric fields (E/N) between parallel-plate electrodes in helium. The left branch of the Paschen curve in the voltage range of 20-350kV and inter-electrode gap range of 0.5-3.5cm is studied analytically and with Monte-Carlo/PIC simulations. The model incorporates electron, ion, and fast neutral species whose energy-dependent anisotropic scattering, as well as backscattering at the electrodes, is carefully taken into account. Our model demonstrates that (1) anisotropic scattering is indispensable for producing reliable results at such high voltage and (2) due to the heavy species backscattered at cathode, breakdown can occur even without electron- and ion-induced ionization of the background gas. Fast atoms dominate in the breakdown process more and more as the applied voltage is increased, due to their increasing ionization cross-section and to the copious flux of energetic fast atoms generated in charge-exchange collisions.

  20. Impact of Solar Array Designs on High Voltage Operations

    Science.gov (United States)

    Brandhorst, Henry W., Jr.; Ferguson, Dale; Piszczor, Mike; ONeill, Mark

    2006-01-01

    As power levels of advanced spacecraft climb above 25 kW, higher solar array operating voltages become attractive. Even in today s satellites, operating spacecraft buses at 100 V and above has led to arcing in GEO communications satellites, so the issue of spacecraft charging and solar array arcing remains a design problem. In addition, micrometeoroid impacts on all of these arrays can also lead to arcing if the spacecraft is at an elevated potential. For example, tests on space station hardware disclosed arcing at 75V on anodized A1 structures that were struck with hypervelocity particles in Low Earth Orbit (LEO) plasmas. Thus an understanding of these effects is necessary to design reliable high voltage solar arrays of the future, especially in light of the Vision for Space Exploration of NASA. In the future, large GEO communication satellites, lunar bases, solar electric propulsion missions, high power communication systems around Mars can lead to power levels well above 100 kW. As noted above, it will be essential to increase operating voltages of the solar arrays well above 80 V to keep the mass of cabling needed to carry the high currents to an acceptable level. Thus, the purpose of this paper is to discuss various solar array approaches, to discuss the results of testing them at high voltages, in the presence of simulated space plasma and under hypervelocity impact. Three different types of arrays will be considered. One will be a planar array using thin film cells, the second will use planar single or multijunction cells and the last will use the Stretched Lens Array (SLA - 8-fold concentration). Each of these has different approaches for protection from the space environment. The thin film cell based arrays have minimal covering due to their inherent radiation tolerance, conventional GaAs and multijunction cells have the traditional cerium-doped microsheet glasses (of appropriate thickness) that are usually attached with Dow Corning DC 93-500 silicone

  1. Formation of Ca3SiO5 prepared by electric and microwave burning

    Institute of Scientific and Technical Information of China (English)

    Kai Wang; Shizong Long; Caixia Yan

    2008-01-01

    A new method of sintering Ca3SiO5 by the combination of conventional and microwave heating methods was studied. The influence of transitional metal oxides such as Fe2O3, Cr2O3, MnO2, and V2O5 used as the additive of microwave absorption on the mi- crowave-promoted burning of Ca3SiO5 was investigated. The experimental results indicate that the new burning technique is capable of promoting the sintering of Ca3SiO5. At 1200-1300℃ in an electric furnace, Ca3SiO5 can be obtained only when the sample is heat- ed in a microwave for 110-240 s, and the free lime content is below 40wt%. Based on the experiments, Fe2O3, Cr2O3, MnO2, and V2O5 can enhance microwave sintering. Amongst them, Cr2O3 is the most effective. The characteristic of the X-ray diffraction peaks of Ca3SiO5 is similar to those of standard Ca3SiO5, but the peaks are wider.

  2. Electricity and fishing - a dangerous mix.

    Science.gov (United States)

    Fodor, Lucian; Bota, Ioan O; Abbas, Yusuf; Fodor, Marius; Ciuce, Constantin

    2011-05-01

    The advent of fishing rods made of carbon fiber and graphite rods has greatly increased the risks of electrical injuries associated with fishing. The braided fishing lines and metal hooks put the fishermen at risk for electrical injuries. We review our burn center's experience with electrical injuries related to fishing activities during the last four years. We retrospectively collected data on patients with electrical burns related to fishing activities between January 2006, when our burns unit was established, and December 2009. Eight patients with electrical burns were admitted during this period of time, five who sustained the injury while fishing, due to contact of the fishing rod with overhead high-voltage cables and three who were injured during illegal fishing, using electricity to stun the fish. The total burn surface area ranged from 0.5% to 70%. Three of the patients sustained fourth degree burns, while the rest had second and third degree burns. One patient underwent scapulohumeral disarticulation and an above-knee amputation. Two patients had fingers and toes amputated. Latissimus dorsi and anterolateral thigh flaps were used to cover the defects in two cases. Local flaps were employed in other two cases to cover the tissue defects. Two patients died. Fishing-related burns and illegal fishing can lead to serious injuries and death. Copyright © 2010 Elsevier Ltd and ISBI. All rights reserved.

  3. Trends of high-voltage technology at the CIGRE 2002; Trends der Hochspannungstechnik: Berichte von der CIGRE 2002

    Energy Technology Data Exchange (ETDEWEB)

    Bohn, T.; Degen, W.; Eckholz, K.; Glaunsinger, W.; Hussels, D.; Kirchesch, P.; Kirchner, M.; Lips, P.; Schwinne, M.; Slupinski, A.

    2002-12-01

    Meeting with the following topics: Study Committees, Rotating Electrical Machines, Transformers, High Voltage Equipment, Insulated Cables, Overhead Lines, Substations, HVDC and Power Electronics, Protections and Automations, System Development and Economics, System Control and Operation, System Environmental Performance, System Technical Performance, Electricity Markets and Regulation, Distribution Systems and Dispersed Generation, Materials and Emerging Technologies, Information Systems and Telecommunications. (orig.)

  4. High-voltage air-core pulse transformers

    Energy Technology Data Exchange (ETDEWEB)

    Rohwein, G. J.

    1981-01-01

    General types of air core pulse transformers designed for high voltage pulse generation and energy transfer applications are discussed with special emphasis on pulse charging systems which operate up to the multi-megavolt range. The design, operation, dielectric materials, and performance are described. It is concluded that high voltage air core pulse transformers are best suited to applications outside the normal ranges of conventional magnetic core transformers. In general these include charge transfer at high power levels and fast pulse generation with comparatively low energy. When properly designed and constructed, they are capable of delivering high energy transfer efficiency and have demonstrated superior high voltage endurance. The principal disadvantage of high voltage air core transformers is that they are not generally available from commercial sources. Consequently, the potential user must become thoroughly familiar with all aspects of design, fabrication and system application before he can produce a high performance transformer system. (LCL)

  5. Simulation Model solves exact the Enigma named Generating high Voltages and high Frequencies by Tesla Coil

    Directory of Open Access Journals (Sweden)

    Simo Janjanin

    2016-11-01

    Full Text Available Simulation model of Tesla coil has been successfully completed, and has been verified the procedure and functioning. The literature and documentation for the model were taken from the rich sources, especially the copies of Tesla patents. The oscillating system‟s electrical scheme consists of the voltage supply 220/50 Hz, Fe transformer, capacitor and belonging chosen electrical components, the air gap in the primary Tesla coil (air transformer and spark gap in the exit of the coil. The investigation of the oscillating process Tesla coil‟s system using the simulation model in MATLAB & SIMULINK have given the exact solution the enigma named the generating high voltage and high frequency the Tesla‟s coil. The inductance voltage from the spark current in the primary (coil with its high voltage impulse excites the oscillating series circuit Ce-L3-R3 on the secondary of the air transformer to its own damped oscillations

  6. Tests of industrial ethylene-propylene rubber high voltage cable for cryogenic use

    CERN Document Server

    Balhan, B; Goddard, B; Muratori, G; Otwinowski, S; Rieubland, Jean Michel; Wang, H; CERN. Geneva. SPS and LEP Division

    1999-01-01

    At the beginning of 1999 UCLA has received a prototype High Voltage Cryogenic Cable supplied fee of charge by Pirelli. The cable is intended for more than ten years of service at 100 kV D.C. and liquid argon temperature. Thecable uses an all welded construction, whichi is axially tight and free of ionizable voids. The cable was submitted to a number of mechanical and electrical tests as described below.

  7. Interaction between High-Voltage Cathode Materials and Ionic Liquids for Novel Li-Ion Batteries

    OpenAIRE

    2012-01-01

    The fast-growing market on electronic portable devices is possibly due to the development of Li-ion batteries. Besides, such batteries are the most promising candidates as energy storage media in (hybrid) electric vehicles, in the near future. However, improvements on electrochemical performances and on safety need to be achieved. With respect to energy density, positive electrodes with a high voltage vs. Li/Li+ are favourable, provided they are stable against the rest of the battery material...

  8. HIGH VOLTAGE SMALL – SIZED ALTERNATIVE CURRENT RESISTIVE DIVIDERS FROM MICROWIRE

    Directory of Open Access Journals (Sweden)

    Berzan V.P.

    2011-04-01

    Full Text Available The paper discusses the design parameters and characteristics of the new product, the resistive voltage divider produced from microwire for measuring high-voltage alternating current. Resistive dividers are designed for use in AC circuits and power-frequency electric traction network traffic. Dividers have smaller mass-dimensional size compared with the measuring voltage transformers and higher accuracy class 0.2 at a fixed frequency.

  9. Transmission Lines or Poles, Electric, Electricity Transmission Lines; electran; Major above ground high voltage electrical transmission lines as shown on USGS 7.5 minute topo quads and/or as confirmed through identification of visible right of way cuts on digital orthophotgraphy., Published in 2001, 1:4800 (1in=400ft) scale, State of Rhode Island and Providence Plantations.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Transmission Lines or Poles, Electric dataset, published at 1:4800 (1in=400ft) scale, was produced all or in part from Orthoimagery information as of 2001. It...

  10. The Experimental Study of Water Chain Formation and Dissipation in High-Frequency and High-Voltage Pulsed Electric Field%高频高压脉冲电场作用下水链形成与消散行为的实验研究1

    Institute of Scientific and Technical Information of China (English)

    李彬; 孙治谦; 王振波; 金有海

    2015-01-01

    In order toinvestigate the mechanism of water chains’ formation and dissipation during the process of electric coalescence in oil further, micro-experiment was carried out to study the patterns of water chains’ formation and dissipation in high-frequency and high-voltage pulsed electric field. There are two patterns of water chains’ formation in W/O emulsions under experimental conditions. Due to the high polarization force in high electricfield, the single droplet breaks up in the middle part to form water chains with length of more than 1000mm. In addition, the membrane of droplets can be broken-down by electrostaticforce in high-frequency and high-voltage pulsed electric field and coalesces to water chains with length of around 268μm. There are also two patterns of water chains’ dissipation in W/O emulsions. Water chains’ own droplets are polarized in high-frequency and high-voltage pulsed electric field, and coalesce when electrostatic stress is higher than interfacial tension. The water chain with length of 51μm and average diameter of 8.8μm coalesces to a 16μm droplet, while the water chain with length of 204μm and average diameter of 20μm coalesces to a water chain with length of 68μm and average diameter of 33μm. When outside droplets touch with droplets of water chains’ end, the charge neutralization occurs, and the charge distribution changes, which leads to water chains’ coalescence dissipation. The outside droplet with diameter of 26μm coalesces with the water chain with length of 37μm and average diameter of 9.3μm to a 30μm droplet, while the outside droplet with diameter of 35μm coalesces with the water chain with length of 259μm and average diameter of 39μm to a water chain with length of 210μm and average diameter of 50μm.%为深入探究原油乳状液静电聚结破乳过程中水链形成、消散行为机理,对高频高压脉冲电场作用下水链形成与消散行为进行显微实验研究,得到乳状液

  11. Optimization of high voltage pulsed electric field on extraction of the total saponins of Gymnema sylvestre by response surface methodology%响应面法优化高压脉冲电场提取匙羹藤总皂苷

    Institute of Scientific and Technical Information of China (English)

    孙建华; 韦泽沼; 刘斌; 廖丹葵; 陈晓光; 童张法

    2011-01-01

    The total saponins of Gymnema sylvestre has been discovered to have hypoglycemic activity. In this study, the total saponins of Gymnema sylvestre was extracted by high voltage pulsed electric field. Single factor examination and response surface analysis experiments were used to investigate the effects of electric field intensity, pulse frequency, extraction time on the extraction of the total saponins of Gymnema sylvestre. The results showed that the optimal process parameters for this method were: material to liquid ratio of 1: 20, the electric field intensity of 16.0 kV/cm, pulse frequency of 30 Hz, and extraction time of 1.2 h. The optimized total saponins extraction yield was 88.74%. A predictive polynomial quadratic equation model was developed by solving the quadratic equation and analyzing the response surface plots. The predicted values were in good agreement with the experimental results.%匙羹藤总皂苷具有降血糖等活性.采用高压脉冲电场辅助提取匙羹藤总皂苷,以匙羹藤总皂苷提取率为指标,在单因素实验基础上采用响应曲面法考察了高压脉冲电场强度、脉冲频率和提取时间对匙羹藤总皂苷提取率的影响,得到提取匙羹藤总皂苷最优工艺条件为:料液比为1∶20,电场强度为16.0 kV/cm,脉冲频率30 Hz,提取时间为1.2 h,此时总皂苷提取率为88.74%.通过回归方程求解和响应曲面分析,得到了二次多项式提取回归模型,经验证实验值与模型预测值拟合性良好.

  12. Unlikely Combination of Experiments With a Novel High-Voltage CIGS Photovoltaic Array: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    del Cueto, J. A.; Sekulic, B. R.

    2006-05-01

    A new high-voltage array comprising bipolar strings of copper indium gallium diselenide (CIGS) photovoltaic (PV) modules was inaugurated in 2005. It is equipped with a unique combination of tests, which likely have never before been deployed simultaneously within a single array: full current-voltage (I-V) traces, high-voltage leakage current measurements, and peak-power tracking or temporal stepped-bias profiling. The array nominally produces 1 kW power at 1 sun. The array's electrical characteristics are continuously monitored and controlled with a programmable electronic load interfaced to a data acquisition system (DAS), that also records solar and meteorological data. The modules are mounted with their frames electrically isolated from earth ground, in order to facilitate measurement of the leakage currents that arise between the high voltage bias developed in the series-connected cells and modules and their mounting frames. Because the DAS can perform stepped biasing of the array as a function of time, synchronous detection of the leakage current data with alternating bias is available. Leakage current data and their dependence on temperature and voltage are investigated. Array power data are analyzed across a wide range of varying illuminations and temperatures from the I-V traces. Array performance is also analyzed from an energy output perspective using peak-power tracking data.

  13. Challenges for High Voltage Testing of UHV Equipment

    Institute of Scientific and Technical Information of China (English)

    Ernst Gockenbach

    2011-01-01

    The increase of voltage level for AC and DC transmission systems requires some changes in the high voltage testing for Ultra High Voltage (UHV) equipment. After a short description of the coordination work in the standard- ization bodies the requirements for UHV equipment are mentioned. The main points concerning high voltage testing of UHV equipment are the impulse shape of standard lightning impulse voltage, the evaluation of the test voltage for impulses with oscillations or overshoot near the peak and the time parameter of switching impulses. The linearity check of the measuring devices, the proximity effect, the wet tests and the atmospheric correction factors are further points to be discussed concerning testing of UHV equipment.

  14. High Voltage Bi-directional Flyback Converter for Capacitive Actuator

    DEFF Research Database (Denmark)

    Thummala, Prasanth; Zhang, Zhe; Andersen, Michael A. E.

    2013-01-01

    This paper presents a high voltage DC-DC converter topology for bi-directional energy transfer between a low voltage DC source and a high voltage capacitive load. The topology is a bi-directional flyback converter with variable switching frequency control during the charge mode, and constant...... switching frequency control during the discharge mode. The converter is capable of charging the capacitive load from 24 V DC source to 2.5 kV, and discharges it to 0 V. The flyback converter has been analyzed in detail during both charge and discharge modes, by considering all the parasitic elements...... in the converter, including the most dominating parameters of the high voltage transformer viz., self-capacitance and leakage inductance. The specific capacitive load for this converter is a dielectric electro active polymer (DEAP) actuator, which can be used as an effective replacement for conventional actuators...

  15. High-voltage live cleaning robot design based on security

    Institute of Scientific and Technical Information of China (English)

    XIE Xiao-peng; XIA Hong-wei; YANG Ru-qing

    2005-01-01

    High-Voltage Live Cleaning Robot works in a hot-line environment (220 kV/330 kV), and so the safety of its application and equipment is most important. In terms of safety, the designs of robot mechanism and control system have been discussed, and the test data are given regarding the control system of a model machine. The model machine of a high-voltage live cleaning robot can satisfy the needs of basic cleaning in common conditions. From manual operation to automation, the cleaning efficiency is improved. The robot can decrease the amount of work, and guarantee security. Among high-voltage live cleaning equipment in China, the cleaning robot is advanced in automation and intelligence.

  16. Optical sensing in high voltage transmission lines using power over fiber and free space optics

    Science.gov (United States)

    Rosolem, João Batista; Bassan, Fabio Renato; Penze, Rivael Strobel; Leonardi, Ariovaldo Antonio; Fracarolli, João Paulo Vicentini; Floridia, Claudio

    2015-12-01

    In this work we propose the use of power over fiber (PoF) and free space optics (FSO) techniques to powering and receive signals from an electrical current sensor placed at high voltage potential using a pair of optical collimators. The technique evaluation was performed in a laboratorial prototype using 62.5/125 μm multimode fiber to study the sensitivity of the optical alignment and the influence of the collimation process in the sensing system wavelengths: data communication (1310 nm) and powering (830 nm). The collimators were installed in a rigid electric insulator in order to maintain the stability of transmission.

  17. Distally based split vastus lateralis myocutaneous flap for reconstruction of post electrical injury defects around knee joint

    Directory of Open Access Journals (Sweden)

    Manish Zade

    2016-11-01

    Conclusions: This new flap is a reliable option for extensive soft tissue defects around knee secondary to high voltage electric burns where free flap is challenging due to deeper location of recipient vessels and damage due to burn injury. Donor area in upper thigh remains hidden and is with no functional deficit. [Int J Res Med Sci 2016; 4(11.000: 4701-4704

  18. 30 CFR 77.807-1 - High-voltage powerlines; clearances above ground.

    Science.gov (United States)

    2010-07-01

    ... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.807-1 High-voltage powerlines; clearances above ground. High-voltage powerlines located above driveways, haulageways, and railroad tracks...

  19. Epidemiology and outcome of burns: early experience at the country's first national burns centre.

    Science.gov (United States)

    Iqbal, Tariq; Saaiq, Muhammad; Ali, Zahid

    2013-03-01

    This study aims to document the epidemiologic pattern and outcome of burn injuries in the country's first national burn centre. This case series study was conducted over a 2-year period at Burns Care Centre (BCC), Pakistan Institute of Medical Sciences (PIMS), Islamabad. The study included all burn injury patients who primarily presented to and were managed at the centre. Those patients who presented more than 24 h after injury or those who were initially managed at some other hospital were excluded from the study. Initial assessment and diagnosis was made by thorough history, physical examination and necessary investigations. Patients with major burns, high voltage electric burns and those needing any surgical interventions were admitted for indoor management. Patients with minor burns were discharged home after necessary emergency management, home medication and follow-up advice. The sociodemographic profile of the patients, site of sustaining burn injury, type and extent (total body surface area (TBSA), skin thickness involved and associated inhalational injury) of burn and outcome in terms of survival or mortality, etc., were all recorded on a proforma. The data were subjected to statistical analysis. Out of a total of 13,295 patients, there were 7503 (56.43%) males and 5792 (43.56%) females. The mean age for adults was 33.63±10.76 years and for children it was 6.71±3.47 years. The household environment constituted the commonest site of burns (68%). Among all age groups and both genders, scalds were the commonest burns (42.48%), followed by flame burns (39%) and electrical burns (9.96%). The affected mean TBSA was 10.64±11.45% overall, while for the hospitalised subset of patients the mean TBSA was 38.04±15.18%. Most of the burns were partial thickness (67%). Inhalation injury was found among 149 (1.12%) patients. Most of the burns were non-intentional and only 96 (0.72%) were intentional. A total of 1405 patients (10.58%) were admitted while the remainder

  20. Characteristics and Breakdown Behaviors of Polysilicon Resistors for High Voltage Applications

    Directory of Open Access Journals (Sweden)

    Xiao-Yu Tang

    2015-01-01

    Full Text Available With the rapid development of the power integrated circuit technology, polysilicon resistors have been widely used not only in traditional CMOS circuits, but also in the high voltage applications. However, there have been few detailed reports about the polysilicon resistors’ characteristics, like voltage and temperature coefficients and breakdown behaviors which are critical parameters of high voltage applications. In this study, we experimentally find that the resistance of the polysilicon resistor with a relatively low doping concentration shows negative voltage and temperature coefficients, while that of the polysilicon resistor with a high doping concentration has positive voltage and temperature coefficients. Moreover, from the experimental results of breakdown voltages of the polysilicon resistors, it could be deduced that the breakdown of polysilicon resistors is thermally rather than electrically induced. We also proposed to add an N-type well underneath the oxide to increase the breakdown voltage in the vertical direction when the substrate is P-type doped.

  1. High-voltage integrated transmitting circuit with differential driving for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Færch, Kjartan Ullitz

    2016-01-01

    In this paper, a high-voltage integrated differential transmitting circuit for capacitive micromachined ultrasonic transducers (CMUTs) used in portable ultrasound scanners is presented. Due to its application, area and power consumption are critical and need to be minimized. The circuitry...... is designed and implemented in AMS 0.35 μ m high-voltage process. Measurements are performed on the fabricated integrated circuit in order to assess its performance. The transmitting circuit consists of a low-voltage control logic, pulse-triggered level shifters and a differential output stage that generates...... pulses at differential voltage levels of 60, 80 and 100 V, a frequency up to 5 MHz and a measured driving strength of 2.03 V/ns with the CMUT electrical model connected. The total on-chip area occupied by the transmitting circuit is 0.18 mm2 and the power consumption at the ultrasound scanner operation...

  2. DEVELOPMENT OF HIGH-VOLTAGE HIGH-FREQUENCY POWER SUPPLY FOR OZONE GENERATION

    Directory of Open Access Journals (Sweden)

    NACERA HAMMADI

    2016-05-01

    Full Text Available A high-voltage high-frequency power supply for ozone generation is presented in this paper. Ozone generation is intended to be used in air and in water disinfection. A power stage consisting of a single-phase full bridge inverter for regulating the output power, a current push-pull inverter (driver and a control circuit are described and analyzed. This laboratory build power supply using a high voltage ferrite transformer and a PIC microcontroller was employed to energize a dielectric barrier discharge (DBD ozone generator. The inverter working on the basis of control strategy is of simple structure and has a variation range of the working frequency in order to obtain the optimal frequency value. The experimental results concerning electrical characterization and water treatment using a cylindrical DBD ozone generator supplied by this power supply are given in the end.

  3. Daikin Advanced Lithium Ion Battery Technology – High Voltage Electrolyte - REVISED

    Energy Technology Data Exchange (ETDEWEB)

    Sunstrom, Joseph [Daikin America, Inc., Orangeburg, NY (United States); Hendershot, Ron E. [Daikin America, Inc., Orangeburg, NY (United States)

    2017-03-06

    An evaluation of high voltage electrolytes which contain fluorochemicals as solvents/additive has been completed with the objective of formulating a safe, stable electrolyte capable of operation to 4.6 V. Stable cycle performance has been demonstrated in LiNi1/3Mn1/3Co1/3O2 (NMC111)/graphite cells to 4.5 V. The ability to operate at high voltage results in significant energy density gain (>30%) which would manifest as longer battery life resulting in higher range for electric vehicles. Alternatively, a higher energy density battery can be made smaller without sacrificing existing energy. In addition, the fluorinated electrolytes examined showed better safety performance when tested in abuse conditions. The results are promising for future advanced battery development for vehicles as well as other applications.

  4. DC high voltage to drive helium plasma jet comprised of repetitive streamer breakdowns

    CERN Document Server

    Wang, Xingxing

    2016-01-01

    This paper demonstrates and studies helium atmospheric pressure plasma jet comprised of series of repetitive streamer breakdowns, which is driven by a pure DC high voltage (auto-oscillations). Repetition frequency of the breakdowns is governed by the geometry of discharge electrodes/surroundings and gas flow rate. Each next streamer is initiated when the electric field on the anode tip recovers after the previous breakdown and reaches the breakdown threshold value of about 2.5 kV/cm. Repetition frequency of the streamer breakdowns excited using this principle can be simply tuned by reconfiguring the discharge electrode geometry. This custom-designed type of the helium plasma jet, which operates on the DC high voltage and is comprised of the series of the repetitive streamer breakdowns at frequency about 13 kHz, is demonstrated.

  5. The monitoring results of electromagnetic radiation of 110-kV high-voltage lines in one urban location in Chongqing P.R. China.

    Science.gov (United States)

    Qin, Qi-Zhong; Chen, Yu; Fu, Ting-Ting; Ding, Li; Han, Ling-Li; Li, Jian-Chao

    2012-03-01

    To understand electromagnetic radiation field strength and its influencing factors of certain 110-kV high-voltage lines in one urban area of Chongqing by measuring 110-kV high-voltage line's electromagnetic radiation level. According to the methodology as determined by the National Hygienic Standards, we selected certain adjacent residential buildings, high-voltage lines along a specific street and selected different distances around its vertical projection point as monitoring points. The levels of electromagnetic radiations were measured respectively. In this investigation within the frequency of 5-1,000 Hz both the electric field strength and magnetic field strength of each monitoring sites were lower than the public exposure standards as determined by the International Commission on Non-Ionizing Radiation Protection. However, the electrical field strength on the roof adjacent to the high-voltage lines was significantly higher than that as measured on the other floors in the same buildings (p electromagnetic radiation measurements of different monitoring points, under the same high-voltage lines, showed the location which is nearer the high-voltage line maintain a consistently higher level of radiation than the more distant locations (p Electromagnetic radiation generated by high-voltage lines decreases proportionally to the distance from the lines. The buildings can to some extent shield (or absorb) the electric fields generated by high-voltage lines nearby. The electromagnetic radiation intensity near high-voltage lines may be mitigated or intensified by the manner in which the high-voltage lines are set up, and it merits attention for the potential impact on human health.

  6. Integrated reconfigurable high-voltage transmitting circuit for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Jørgensen, Ivan Harald Holger

    2015-01-01

    In this paper a high-voltage transmitting circuit aimed for capacitive micromachined ultrasonic transducers (CMUTs) used in scanners for medical applications is designed and implemented in a 0.35 μm high-voltage CMOS process. The transmitting circuit is reconfigurable externally making it able...... performance. The design occupies an on-chip area of 0.938 mm2 and the power consumption of a 128-element transmitting circuit array that would be used in an portable ultrasound scanner is found to be a maximum of 181 mW....

  7. Integrated reconfigurable high-voltage transmitting circuit for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Jørgensen, Ivan Harald Holger;

    2015-01-01

    In this paper a high-voltage transmitting circuit aimed for capacitive micromachined ultrasonic transducers (CMUTs) used in scanners for medical applications is designed and implemented in a 0.35 μm high-voltage CMOS process. The transmitting circuit is reconfigurable externally making it able...... performance. The design occupies an on-chip area of 0.938 mm2 and the power consumption of a 128-element transmitting circuit array that would be used in an portable ultrasound scanner is found to be a maximum of 181 mW....

  8. Integrated differential high-voltage transmitting circuit for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Farch, Kjartan

    2015-01-01

    In this paper an integrated differential high-voltage transmitting circuit for capacitive micromachined ultrasonic transducers (CMUTs) used in portable ultrasound scanners is designed and implemented in a 0.35 μm high-voltage process. Measurements are performed on the integrated circuit in order...... to assess its performance. The circuit generates pulses at differential voltage levels of 60V, 80V and 100 V, a frequency up to 5MHz and a measured driving strength of 1.75 V/ns with the CMUT connected. The total on-chip area occupied by the transmitting circuit is 0.18 mm2 and the power consumption...

  9. High voltage pulsed cable design: a practical example

    Energy Technology Data Exchange (ETDEWEB)

    Kewish, R.W. Jr.; Boicourt, G.P.

    1979-01-01

    The design of optimum high voltage pulse cable is difficult because very little emperical data are available on performance in pulsed applications. This paper follows the design and testing of one high voltage pulse cable, 40/100 trigger cable. The design was based on an unproven theory and the impressive outcome lends support to the theory. The theory is outlined and it is shown that there exists an inductance which gives a cable of minimum size for a given maximum stress. Test results on cable manufactured according to the design are presented and compared with the test results on the cable that 40/100 replaces.

  10. High voltage switch triggered by a laser-photocathode subsystem

    Science.gov (United States)

    Chen, Ping; Lundquist, Martin L.; Yu, David U. L.

    2013-01-08

    A spark gap switch for controlling the output of a high voltage pulse from a high voltage source, for example, a capacitor bank or a pulse forming network, to an external load such as a high gradient electron gun, laser, pulsed power accelerator or wide band radar. The combination of a UV laser and a high vacuum quartz cell, in which a photocathode and an anode are installed, is utilized as triggering devices to switch the spark gap from a non-conducting state to a conducting state with low delay and low jitter.

  11. Mobile Electric Power Technologies for the Army of the Future: Engines, Power Source, and Electrical Aspects

    Science.gov (United States)

    1988-01-01

    developed across the beta"-alumina barrier forces electrons to flow to the porous electrode surface through the load , producing electrical work...Engines Not Generally Available on a Commercial Basis 72 Steady- Flow Combustion Engines Capable of Burning JP-8 75 Direct Energy Conversion 77 Nuclear...off thyristor HAEMP High altitude electromagnetic pulse HMMWV High Mobility Multipurpose Wheeled Vehicle xv HVDC High-voltage direct current IC

  12. Feasibility Study of Supercritical Light Water Cooled Fast Reactors for Actinide Burning and Electric Power Production

    Energy Technology Data Exchange (ETDEWEB)

    Mac Donald, Philip Elsworth; Buongiorno, Jacopo; Davis, Cliff Bybee; Weaver, Kevan Dean

    2002-01-01

    The use of supercritical temperature and pressure light water as the coolant in a direct-cycle nuclear reactor offers potential for considerable plant simplification and consequent capital and O&M cost reduction compared with current light water reactor (LWR) designs. Also, given the thermodynamic conditions of the coolant at the core outlet (i.e. temperature and pressure beyond the water critical point), very high thermal efficiencies of the power conversion cycle are possible (i.e. up to 46%). Because no change of phase occurs in the core, the need for steam separators and dryers as well as for BWR-type recirculation pumps is eliminated, which, for a given reactor power, results in a substantially shorter reactor vessel than the current BWRs. Furthermore, in a direct cycle the steam generators are not needed. If a tight fuel rod lattice is adopted, it is possible to significantly reduce the neutron moderation and attain fast neutron energy spectrum conditions. In this project a supercritical water reactor concept with a simple, blanket-free, pancake-shaped core will be developed. This type of core can make use of either fertile or fertile-free fuel and retain the hard spectrum to effectively burn plutonium and minor actinides from LWR spent fuel while efficiently generating electricity.

  13. On-chip High-Voltage Generator Design

    CERN Document Server

    Tanzawa, Toru

    2013-01-01

    This book describes high-voltage generator design with switched-capacitor multiplier techniques.  The author provides various design techniques for switched-capacitor on-chip high-voltage generators, including charge pump circuits, regulators, level shifters, references, and oscillators.  Readers will see these techniques applied to system design in order to address the challenge of how the on-chip high-voltage generator is designed for Flash memories, LCD drivers, and other semiconductor devices to optimize the entire circuit area and power efficiency with a low voltage supply, while minimizing the cost.   ·         Shows readers how to design charge pump circuits with lower voltage operation, higher power efficiency, and smaller circuit area; ·         Describes comprehensive circuits and systems design of on-chip high-voltage generators; ·         Covers all the component circuit blocks, including charge pumps, pump regulators, level shifters, oscillators, and references.

  14. Optical Spectra of the High Voltage Erosive Water Discharge

    CERN Document Server

    Pirozerski, A L

    2008-01-01

    In the present paper kinetics of emission spectra of the high voltage erosive water discharge at near ultraviolet and visible spectral ranges has been investigated. Obtained results show a similarity of physical properties of this discharge (and of corresponding plasmoids) to that of some other types of erosional discharges which also result in the formation of dust-gas fireballs.

  15. Measurements for validation of high voltage underground cable modelling

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Gudmundsdottir, Unnur Stella; Wiechowski, Wojciech Tomasz

    2009-01-01

    This paper discusses studies concerning cable modelling for long high voltage AC cable lines. In investigating the possibilities of using long cables instead of overhead lines, the simulation results must be trustworthy. Therefore a model validation is of great importance. This paper describes...

  16. COTS Li-Ion Cells in High Voltage Batteries

    Science.gov (United States)

    Davies, Francis; Darcy, Eric; Jeevarajan, Judy; Cowles, Phil

    2003-01-01

    Testing at NASA JSC and COMDEV shows that Commercial Off the Shelf (COTS) Li Ion cells can not be used in high voltage batteries safely without considering the voltage stresses that may be put on the protective devices in them during failure modes.

  17. Modeling of skin cooling, blood flow, and optical properties in wounds created by electrical shock

    Science.gov (United States)

    Nguyen, Thu T. A.; Shupp, Jeffrey W.; Moffatt, Lauren T.; Jordan, Marion H.; Jeng, James C.; Ramella-Roman, Jessica C.

    2012-02-01

    High voltage electrical injuries may lead to irreversible tissue damage or even death. Research on tissue injury following high voltage shock is needed and may yield stage-appropriate therapy to reduce amputation rate. One of the mechanisms by which electricity damages tissue is through Joule heating, with subsequent protein denaturation. Previous studies have shown that blood flow had a significant effect on the cooling rate of heated subcutaneous tissue. To assess the thermal damage in tissue, this study focused on monitoring changes of temperature and optical properties of skin next to high voltage wounds. The burns were created between left fore limb and right hind limb extremities of adult male Sprague-Dawley rats by a 1000VDC delivery shock system. A thermal camera was utilized to record temperature variation during the exposure. The experimental results were then validated using a thermal-electric finite element model (FEM).

  18. Concept design of the high voltage transmission system for the collider tunnel

    Science.gov (United States)

    Norman, L. S.

    1992-03-01

    In order to provide electrical service to the Superconducting Super Collider Laboratory (SSCL) 54-mile-circumference collider of 125 MVA at 69 kV or 155 MVA at 138 kV of distributed power, it must be demonstrated that the concept design for a high-voltage transmission system can meet the distribution requirements of the collider electrical system with its cryogenic system's large motor loads and its pulsed power technical systems. It is a practical design, safe for operating personnel and cost-effective. The normal high-voltage transmission techniques of overhead and underground around the 54-mile collider tunnel could not be applied because of technical and physical constraints, or was environmentally unacceptable. The approach taken to solve these problems is the installation of 69-kV or 138-kV exposed solid dielectric transmission cable inside the collider tunnel with the superconducting magnets, cryogenic piping, electrical medium, and low-voltage distribution systems, and electronic/instrumentation wiring systems. This mixed-use approach has never been attempted in a collider tunnel. Research into all aspects of the engineering and installation problems and consultation with transmission cable manufacturers, electrical utilities, and European entities with similar installations--such as the Channel Tunnel--demonstrate that the concept design is feasible and practical. This paper presents a history of the evolution of the concept design. Design studies are underway to determine the system configuration and voltages. Included in this report are tunnel transmission cable system considerations and evaluation of solid dielectric high-voltage cable design.

  19. Arcing and discharges in high-voltage subsystems of Space Station

    Science.gov (United States)

    Singh, N.

    1988-01-01

    Arcing and other types of electrical discharges are likely to occur in high-voltage subsystems of the Space Station. Results from ground and space experiments on the arcing of solar cell arrays are briefly reviewed, showing that the arcing occurs when the conducting interconnects in the arrays are at negative potential above a threshold, which decreases with the increasing plasma density. Furthermore, above the threshold voltages the arcing rate increases with the plasma density. At the expected operating voltages (approximately 200 V) in the solar array for the space station, arcing is expected to occur even in the ambient ionospheric plasma. If the ionization of the contaminants increases the plasma density near the high-voltage systems, the adverse effects of arcing on the solar arrays and the space station are likely to be enhanced, In addition to arcing other discharge processes are likely to occur in high-voltage subsystems. For example, Paschen discharge is likely to occur when the neutral density N sub n greater that 10 to the 12th cu cm, the corresponding neutral pressure P greater than 3 x 10 to the -5 Torr.

  20. High-Voltage Electroporation of Bacteria: Genetic Transformation of Campylobacter jejuni with Plasmid DNA

    Science.gov (United States)

    Miller, Jeff F.; Dower, William J.; Tompkins, Lucy S.

    1988-02-01

    Electroporation permits the uptake of DNA by mammalian cells and plant protoplasts because it induces transient permeability of the cell membrane. We investigated the utility of high-voltage electroporation as a method for genetic transformation of intact bacterial cells by using the enteric pathogen Campylobacter jejuni as a model system. This report demonstrates that the application of high-voltage discharges to bacterial cells permits genetic transformation. Our method involves exposure of a Campylobacter cell suspension to a high-voltage exponential decay discharge (5-13 kV/cm) for a brief period of time (resistance-capacitance time constant = 2.4-26 msec) in the presence of plasmid DNA. Electrical transformation of C. jejuni results in frequencies as high as 1.2 × 106 transformants per μ g of DNA. We have investigated the effects of pulse amplitude and duration, cell growth conditions, divalent cations, and DNA concentration on the efficiency of transformation. Transformants of C. jejuni obtained by electroporation contained structurally intact plasmid molecules. In addition, evidence is presented that indicates that C. jejuni possesses DNA restriction and modification systems. The use of electroporation as a method for transforming other bacterial species and guidelines for its implementation are also discussed.

  1. A Fiber-Optic Sensor for Acoustic Emission Detection in a High Voltage Cable System

    Directory of Open Access Journals (Sweden)

    Tongzhi Zhang

    2016-11-01

    Full Text Available We have proposed and demonstrated a Michelson interferometer-based fiber sensor for detecting acoustic emission generated from the partial discharge (PD of the accessories of a high-voltage cable system. The developed sensor head is integrated with a compact and relatively high sensitivity cylindrical elastomer. Such a sensor has a broadband frequency response and a relatively high sensitivity in a harsh environment under a high-voltage electric field. The design and fabrication of the sensor head integrated with the cylindrical elastomer is described, and a series of experiments was conducted to evaluate the sensing performance. The experimental results demonstrate that the sensitivity of our developed sensor for acoustic detection of partial discharges is 1.7 rad / ( m ⋅ Pa . A high frequency response up to 150 kHz is achieved. Moreover, the relatively high sensitivity for the detection of PD is verified in both the laboratory environment and gas insulated switchgear. The obtained results show the great potential application of a Michelson interferometer-based fiber sensor integrated with a cylindrical elastomer for in-situ monitoring high-voltage cable accessories for safety work.

  2. A Fiber-Optic Sensor for Acoustic Emission Detection in a High Voltage Cable System.

    Science.gov (United States)

    Zhang, Tongzhi; Pang, Fufei; Liu, Huanhuan; Cheng, Jiajing; Lv, Longbao; Zhang, Xiaobei; Chen, Na; Wang, Tingyun

    2016-11-30

    We have proposed and demonstrated a Michelson interferometer-based fiber sensor for detecting acoustic emission generated from the partial discharge (PD) of the accessories of a high-voltage cable system. The developed sensor head is integrated with a compact and relatively high sensitivity cylindrical elastomer. Such a sensor has a broadband frequency response and a relatively high sensitivity in a harsh environment under a high-voltage electric field. The design and fabrication of the sensor head integrated with the cylindrical elastomer is described, and a series of experiments was conducted to evaluate the sensing performance. The experimental results demonstrate that the sensitivity of our developed sensor for acoustic detection of partial discharges is 1.7 rad / ( m ⋅ Pa ) . A high frequency response up to 150 kHz is achieved. Moreover, the relatively high sensitivity for the detection of PD is verified in both the laboratory environment and gas insulated switchgear. The obtained results show the great potential application of a Michelson interferometer-based fiber sensor integrated with a cylindrical elastomer for in-situ monitoring high-voltage cable accessories for safety work.

  3. Reliability and Power Quality Evaluation of High-Voltage Supplied Customer

    Science.gov (United States)

    Yoshino, Jun; Kita, Hiroyuki; Tanaka, Eiichi; Hasegawa, Jun; Kubo, Hiroshi; Yonaga, Shigeru

    Recently, a number of electric consumers have concerned about the reliability of electricity to be served. For example, some consumers need the electricity with a higher reliability by the automation of manufacturing processes. On the other hand, some consumers need the electricity of a cheaper price even if the reliability becomes a little worse. Under such circumstances, it is necessary that power suppliers evaluate the needs of every consumers precisely and propose the most desirable measures for meeting their requirements. This paper develops a tool to analyze the reliability for high-voltage supplied consumers quantitatively. Further, this paper presents a method for evaluating the outage cost of consumers to help them choose the most appropriate measures for maintaining the reliability. The proposed method applies the fuzzy reasoning approach. The validity of the proposed method is ascertained through some numerical simulations.

  4. 30 CFR 75.822 - Underground high-voltage longwall cables.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground high-voltage longwall cables. 75... MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution High-Voltage Longwalls § 75.822 Underground high-voltage longwall cables. In addition to the high...

  5. 30 CFR 18.53 - High-voltage longwall mining systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage longwall mining systems. 18.53... and Design Requirements § 18.53 High-voltage longwall mining systems. (a) In each high-voltage motor-starter enclosure, with the exception of a controller on a high-voltage shearer, the disconnect...

  6. 30 CFR 77.802 - Protection of high-voltage circuits; neutral grounding resistors; disconnecting devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection of high-voltage circuits; neutral... AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.802 Protection of high-voltage circuits; neutral grounding resistors; disconnecting devices. High-voltage...

  7. 30 CFR 75.810 - High-voltage trailing cables; splices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage trailing cables; splices. 75.810... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.810 High-voltage trailing cables; splices. In the case of high-voltage cables used as...

  8. 30 CFR 75.812-2 - High-voltage power centers and transformers; record of examination.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage power centers and transformers... High-Voltage Distribution § 75.812-2 High-voltage power centers and transformers; record of examination... record shall be kept in a book approved by the Secretary. High-Voltage Longwalls Source: 67 FR 11001,...

  9. 30 CFR 77.804 - High-voltage trailing cables; minimum design requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage trailing cables; minimum design... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.804 High-voltage trailing cables; minimum design requirements. (a) High-voltage trailing cables used in resistance grounded systems shall...

  10. 30 CFR 77.800 - High-voltage circuits; circuit breakers.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage circuits; circuit breakers. 77.800... COAL MINES Surface High-Voltage Distribution § 77.800 High-voltage circuits; circuit breakers. High-voltage circuits supplying power to portable or mobile equipment shall be protected by suitable...

  11. Effect of high-voltage impulse current on the structure and function of rabbit heart

    Directory of Open Access Journals (Sweden)

    Xin-ping XU

    2011-06-01

    Full Text Available Objective To explore the effect of high-voltage impulse current(HVIC on the structure and function of rabbit heart.Methods Sixty healthy male rabbits were involved in present study and divided into 6 groups randomly(n=10.The rabbits were then shocked using a high-voltage pulse generator with current intensity of 0,50,100,150,250 and 500mA(pulse width 100μs,duration 5s respectively.The heart rate and electrocardiogram(ECG of rabbits were detected before and 0,1,3,7,14 and 28 days after the electric shock.Moreover,the myocardial tissue of rabbits was obtained immediately and 28 days after shock to observe the pathological changes.Results Immediately after electric shock of 50 to 500mA,the heart rate of rabbit increased by different degree,and the ECG showed arrhythmia,myocardial ischemia,atrial fibrillation and atrioventricular block,and the changes recovered gradually one day later.The pathological observation showed cell swelling,separation of myofibril and sarcoplasmic condensation of Purkinje fibers immediately after electric shock of 50 to 500mA,and the changes recovered 28 days after shock.The cardiac injuries aggravated with the increasing of current intensity,especially when it exceeded 150mA,and the recovery time prolonged.Conclusion High-voltage impulse current may induce recoverable injuries on heart structure and function,and the damage effect shows a correlation with the current intensity.

  12. An atmospheric pressure plasma source driven by a train of monopolar high voltage pulses superimposed to a dc voltage

    OpenAIRE

    Stoican, O.S.

    2011-01-01

    Abstract An atmospheric pressure plasma source supplied by an electrical circuit consisting of two voltage sources in parallel connection is reported. One of them is a low-power self-oscillating flyback converter which produces negative voltage pulses with an amplitude of several kilovolts. The high voltage pulses are necessary to ignite an electrical discharge between the electrodes at atmospheric pressure. An additional dc source delivering several hundreds of volts at a few hund...

  13. Planar LTCC transformers for high voltage flyback converters: Part II.

    Energy Technology Data Exchange (ETDEWEB)

    Schofield, Daryl (NASCENTechnology, Inc., Watertown, SD); Schare, Joshua M., Ph.D.; Slama, George (NASCENTechnology, Inc., Watertown, SD); Abel, David (NASCENTechnology, Inc., Watertown, SD)

    2009-02-01

    This paper is a continuation of the work presented in SAND2007-2591 'Planar LTCC Transformers for High Voltage Flyback Converters'. The designs in that SAND report were all based on a ferrite tape/dielectric paste system originally developed by NASCENTechnoloy, Inc, who collaborated in the design and manufacturing of the planar LTCC flyback converters. The output/volume requirements were targeted to DoD application for hard target/mini fuzing at around 1500 V for reasonable primary peak currents. High voltages could be obtained but with considerable higher current. Work had begun on higher voltage systems and is where this report begins. Limits in material properties and processing capabilities show that the state-of-the-art has limited our practical output voltage from such a small part volume. In other words, the technology is currently limited within the allowable funding and interest.

  14. A Review of High Voltage Drive Amplifiers for Capacitive Actuators

    DEFF Research Database (Denmark)

    Huang, Lina; Zhang, Zhe; Andersen, Michael A. E.

    2012-01-01

    This paper gives an overview of the high voltage amplifiers, which are used to drive capacitive actuators. The amplifiers for both piezoelectric and DEAP (dielectric electroactive polymer) actuator are discussed. The suitable topologies for driving capacitive actuators are illustrated in detail, ......, including linear as well as switched mode amplifiers. In the past much attention has been paid on the driver for piezoelectric actuator. As DEAP is a type of new material, there is not much literature reference for it.......This paper gives an overview of the high voltage amplifiers, which are used to drive capacitive actuators. The amplifiers for both piezoelectric and DEAP (dielectric electroactive polymer) actuator are discussed. The suitable topologies for driving capacitive actuators are illustrated in detail...

  15. Connection for transfer of Liquid Nitrogen from High Voltage to ground potential

    DEFF Research Database (Denmark)

    Rasmussen, Claus Nygaard; Hansen, Finn; Willén, Dag

    2001-01-01

    In order to operate a superconducting cable conductor it must be kept at a cryogenic temperature (e.g. using liquid nitrogen). The superconducting cable conductor is at high voltage and the cooling equipment is kept at ground potential. This requires a thermally insulating connection that is also...... strength. However, samples of ExpancelÒ (polymer foam) have recently proved to withstand large electrical fields at room temperature as well as at cryogenic temperatures. In this work, two prototype devices have been tested with respect to the partial discharge inception voltage, thermal insulation...

  16. Optical fiber sensor of partial discharges in High Voltage DC experiments

    Science.gov (United States)

    Búa-Núñez, I.; Azcárraga-Ramos, C. G.; Posada-Román, J. E.; Garcia-Souto, J. A.

    2014-05-01

    A setup simulating High Voltage DC (HVDC) transformers barriers was developed to demonstrate the effectiveness of an optical fiber (OF) sensor in detecting partial discharges (PD) under these peculiar conditions. Different PD detection techniques were compared: electrical methods, and acoustic methods. Standard piezoelectric sensors (R15i-AST) and the above mentioned OF sensors were used for acoustic detection. The OF sensor was able to detect PD acoustically with a sensitivity better than the other detection methods. The multichannel instrumentation system was tested in real HVDC conditions with the aim of analyzing the behavior of the insulation (mineral oil/pressboard).

  17. Observation of hard radiations in a laboratory atmospheric high-voltage discharge

    CERN Document Server

    Agafonov, A V; Chubenko, A P; Oginov, A V; Rodionov, A A; Rusetskiy, A S; Ryabov, V A; Shepetov, A L; Shpakov, K V

    2016-01-01

    The new results concerning neutron emission detection from a laboratory high-voltage discharge in the air are presented. Data were obtained with a combination of plastic scintillation detectors and $^3$He filled counters of thermal neutrons. Strong dependence of the hard x-ray and neutron radiation appearance on the field strength near electrodes, which is determined by their form, was found. We have revealed a more sophisticated temporal structure of the neutron bursts observed during of electric discharge. This may indicate different mechanisms for generating penetrating radiation at the time formation and development of the atmospheric discharge.

  18. Summary of transient high-voltage calculations for the FRX-C experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kewish, R.W. Jr.; Rej, D.J.

    1982-06-01

    Calculations of the electrical circuit equations are performed over a wide range of parameters corresponding to the FRX-C field-reversed THETA-pinch experiment at Los Alamos. Without any plasma or external damping, serious voltage doubling and quadrupling of the main capacitor bank charge voltage are observed. These oscillating high voltages are found to be adequately suppressed by the strategic placement of external snubber circuitry. On the other hand, no doubling of the THETA-pinch preionization bank charge voltage is found. Calculations of the equations for the z-pinch preionization circuit are also performed.

  19. The interaction of high voltage systems with the environments of the moon and Mars

    Science.gov (United States)

    Hillard, G. B.; Kolecki, Joseph C.

    1993-01-01

    An evaluation is made of the consequences of the interaction of high-voltage spacecraft systems designed for use in orbit or on the lunar and Martian surfaces with such environmental components as electrically charged dust, low pressure atmospheres, ionospheric plasmas and neutral gas species, and chemically reactive species. An account is given of plausible means for obtaining the requisite data and developing priorities for the study of each of the identified interactions. Attention is given to the computational tools whose development is required for the simulation and quantification of risk factors for the various likely interactions.

  20. An Optoelectronic High-voltage Probe for Measuring Impulse Voltage Distribution of HVDC Converter Valve

    Institute of Scientific and Technical Information of China (English)

    方志; 邱毓昌

    2007-01-01

    A high-voltage optoelectronic probe is developed for measuring impulse voltage distribution along thyristor units in the HVDC converter valve. The dimension of the resistive voltage divider is optimized by means of numerical compttation of electric field. A pulse frequency modulation (PFM) mode is adopted for the data transmission link because of its immunity to high-intensity electromagnetic interference. Experimental results indicate that the linearity deviation for the whole measuring system is within ± 0.15 %, and therefore it can meet requirements specified by IEC60700-1.

  1. High voltage series resonant inverter ion engine screen supply. [SCR series resonant inverter for space applications

    Science.gov (United States)

    Biess, J. J.; Inouye, L. Y.; Shank, J. H.

    1974-01-01

    A high-voltage, high-power LC series resonant inverter using SCRs has been developed for an Ion Engine Power Processor. The inverter operates within 200-400Vdc with a maximum output power of 2.5kW. The inverter control logic, the screen supply electrical and mechanical characteristics, the efficiency and losses in power components, regulation on the dual feedback principle, the SCR waveforms and the component weight are analyzed. Efficiency of 90.5% and weight density of 4.1kg/kW are obtained.

  2. A New Phase-Shifted Cascade High Voltage Inverter

    Institute of Scientific and Technical Information of China (English)

    Lau Eng Tin

    2005-01-01

    This paper presents a unique novel design of the phase-shifted cascade high voltage inverter. Thehigh voltage inverter utilizes fewer power switches and supplies a balance load. The usage of phase shifttransformer and phase shifting SPWM ensures that input and output harmonic wave content is low and outputvoltage change (du/dt) has a low rate, meeting all the requirements of the power authorities. The most out-standing feature is the energy saving with very fast cost recovery.

  3. Laser-triggered high-voltage plasma switching with diffractive optics.

    Science.gov (United States)

    Ekberg, M; Sunesson, A; Bergkvist, M; Gustavsson, A; Isberg, J; Bernhoff, H; Skytt, P; Bengtsson, J; Hård, S; Larsson, M

    2001-06-01

    High-power lasers can be used to induce ionization of gases and thereby enable rapid triggering of electrical discharge devices, potentially faster than any devices based on mechanical or solid-state switching. With diffractive optical elements (DOEs) the laser light can conveniently be directed to positions within the gas so that an electrical discharge between two high-voltage electrodes is triggered reliably and rapidly. Here we report on two different types of DOE used for creating an electrical discharge in pure argon for potential high-voltage applications. One is the diffractive equivalent of a conventional axicon that yields an extended, and continuous, high-intensity focal region between the electrodes. The other is a multiple-focal-distance kinoform--a DOE that is designed to produce a linear array of 20 discrete foci, with high peak intensities, between the electrodes. We show that DOEs enable efficient, rapid switching and may provide increased flexibility in the design of novel electrode configurations.

  4. Qualification High Voltage Testing of Short Triax HTS Cables in the Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    James, David Randy [ORNL; Sauers, Isidor [ORNL; Ellis, Alvin R [ORNL; Tuncer, Enis [ORNL; Gouge, Michael J [ORNL; Demko, Jonathan A [ORNL; Duckworth, Robert C [ORNL; Rey, Christopher M [ORNL

    2009-01-01

    In order to qualify the electrical insulation design of future HTS cables installed in the electric grid, a number of high voltage qualification tests are generally performed in the laboratory on either single-phase model cables and/or actual three-phase cable samples. Prior to installation of the 200-m Triax HTS cable at the American Electric Power Bixby substation near Columbus, Ohio, in September, 2006, such tests were conducted on both single-phase model cables made at ORNL and tri-axial cable sections cut off from cable made on a production run. The three-phase tri-axial design provides some specific testing challenges since the ground shield and three phases are concentric about a central former with each phase separated by dielectric tape insulation immersed in liquid nitrogen. The samples were successfully tested and qualified for partial discharge inception, AC withstand, and lightning impulse where voltage is applied to one phase with the other phases grounded. In addition one of the phase pairs was tested for dc withstand as a ldquoworst caserdquo scenario to simulate the effect of VLF (Very Low Frequency) tests on the actual cable installed at the Bixby site. The model and prototype cables will be described and the high voltage test results summarized.

  5. Advances in high voltage power switching with GTOs

    Energy Technology Data Exchange (ETDEWEB)

    Podlesak, T.F. (US Army Electronic Technology and Devices Lab., Fort Monmouth, NJ (US)); McMurray, J.A. (Vitronics, Eatontown, NJ (US)); Carter, J.L.

    1990-12-01

    The control of high voltage at high power, particularly opening switches, has been difficult in the past. Using gate turnoff thyristors (GTOs) arranged in series enables large currents to be switched at high voltage. A high voltage opening switch has been successfully demonstrated in our laboratory. This switch uses GTOs in series and successfully operates at voltages higher than the rated voltage of the individual devices. It is believed that this is the first time this has been successfully demonstrated, in that GTOs have been operated in series before, but always in a manner as to not exceed the voltage capability of the individual devices. In short, the devices have not worked together, sharing the voltage, but one device has been operated using several backup devices. Of particular interest is how well the individual devices share the voltage applied to them. Equal voltage sharing between devices is absolutely essential, in order to not exceed the voltage rating of any of the devices in the series chain. This is accomplished at high (microsecond) switching speeds. Thus, the system is useful for high frequency applications as well as high power, making for a flexible circuit system element. This paper reports on this demonstration system that is rated at 5 KV and uses 1 KV devices. A larger 24 KV system is under design and will use 4.5 KV devices. In order to design the 24 KV switch, the safe operating area of the large devices must be known thoroughly.

  6. New perspectives in vacuum high voltage insulation. I. The transition to field emission

    CERN Document Server

    Diamond, W T

    1998-01-01

    Vacuum high-voltage insulation has been investigated for many years. Typically, electrical breakdown occurs between two broad-area electrodes at electric fields 100-1000 times lower than the breakdown field (about 5000 MV/m) between a well-prepared point cathode and a broad-area anode. Explanations of the large differences remain unsatisfactory, usually evoking field emission from small projections on the cathode that are subject to higher peak fields. The field emission then produces secondary effects that lead to breakdown. This article provides a significant resolution to this long standing problem. Field emission is not present at all fields, but typically starts after some process occurs at the cathode surface. Three effects have been identified that produce the transition to field emission: work function changes; mechanical changes produced by the strong electrical forces on the electrode surfaces; and gas desorption from the anode with sufficient density to support an avalanche discharge. Material adso...

  7. Measurement of Electrical Conductivity for a Biomass Fire

    Directory of Open Access Journals (Sweden)

    Mal Heron

    2008-08-01

    Full Text Available A controlled fire burner was constructed where various natural vegetation species could be used as fuel. The burner was equipped with thermocouples to measure fuel surface temperature and used as a cavity for microwaves with a laboratory quality 2- port vector network analyzer to determine electrical conductivity from S-parameters. Electrical conductivity for vegetation material flames is important for numerical prediction of flashover in high voltage power transmission faults research. Vegetation fires that burn under high voltage transmission lines reduce flashover voltage by increasing air electrical conductivity and temperature. Analyzer determined electrical conductivity ranged from 0.0058 - 0.0079 mho/m for a fire with a maximum temperature of 1240 K.

  8. Spatial and temporal instabilities in high voltage power devices

    Energy Technology Data Exchange (ETDEWEB)

    Milady, Saeed

    2010-01-29

    Dynamic avalanche can occur during the turn-off process of high voltage bipolar devices, e.g. IGBTs and p{sup +}n{sup -}n{sup +} power diodes, that may result in spatial instabilities of the homogeneous current density distribution across the device and the formation of current filaments. Filaments may cause the destruction of the device, mainly because of the high local temperatures. The first part of this work is dedicated to the current filament behavior. The positive feedback mechanisms caused by the transient current flow through the gate capacitance of an IGBT operating under short circuit conditions may result in oscillations and temporal instabilities of the IGBT current. The oscillations may cause electromagnetic interference (EMI). Furthermore, the positive feedback mechanism may accelerate the over-heating of the device and result in a thermal run-away. This is the subject of the second part of this work. In the first part of this work using the device simulation results of power diodes the underlying physical mechanisms of the filament dynamic is investigated. Simulation results of diode structures with evenly distributed doping inhomogeneities show that, the filament motion gets smoother as the distance between the inhomogeneities decreases. Hopping to faraway inhomogeneities turns into the hopping to neighboring ones and finally a smooth motion. In homogeneous structures the slow inhibitory effect of the electron-hole plasma extraction and the fast activation, due to hole current flowing along the filament, result in a smooth filament motion. An analytical model for the filament velocity under isothermal conditions is presented that can reproduce the simulation data satisfactorily. The influence of the boundary conditions on the filament behavior is discussed. The positive beveled edge termination prohibits a long stay of the filament at the edge reducing the risk of filament pinning. Self-heating effects may turn the initially electrically triggered

  9. Large-Scale Electrochemical Energy Storage in High Voltage Grids: Overview of the Italian Experience

    Directory of Open Access Journals (Sweden)

    Roberto Benato

    2017-01-01

    Full Text Available This paper offers a wide overview on the large-scale electrochemical energy projects installed in the high voltage Italian grid. Detailed descriptions of energy (charge/discharge times of about 8 h and power intensive (charge/discharge times ranging from 0.5 h to 4 h installations are presented with some insights into the authorization procedures, safety features, and ancillary services. These different charge/discharge times reflect the different operation uses inside the electric grid. Energy intensive storage aims at decoupling generation and utilization since, in the southern part of Italy, there has been a great growth of wind farms: these areas are characterized by a surplus of generation with respect to load absorption and to the net transport capacity of the 150 kV high voltage backbones. Power intensive storage aims at providing ancillary services inside the electric grid as primary and secondary frequency regulation, synthetic rotational inertia, and further functionalities. The return on experience of Italian installations will be able to play a key role also for other countries and other transmission system operators.

  10. Reliability analysis for the 220 kV Libyan high voltage communication system

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, O.S.A.; AlAthram, A.Y. [General Electric Company of Libya (Libyan Arab Jamahiriya). Development Dept.

    2007-07-01

    Electric utilities are expanding their networks to include fiber-optic communications, which offer high capacity with reliable performance at low cost. Fiber-optic networks offer a feasible technical solution for leasing excess capacity. They can be readily deployed under a wide range of network configurations and can be upgraded rapidly. This study evaluated the reliability index for the communication network of Libya's 220 kV high voltage subsystem operated by the General Electric Company of Libya (GECOL). The schematic diagrams of the communication networks were presented for both power line carriers and fiber optics networks. A reliability analysis for the two communication networks was performed through the existing communication equipment. The reliability values revealed that the fiber optics system has several advantages such as a large bandwidth for high quality data transmission; immunity to electromagnetic interference; low attenuation which allows for extended cable transmission; ability to be used in dangerous environments; a higher degree of security; and, a high capacity through existing conduits due to its light weight and small diameter. However, it was noted that although fiber optic communications may be more reliable and provide the clearest signal, the powerline communication (PLC) system has more redundancy, particularly in the case of outdoor components where the PLC has more power line to carry the signals, while the fiber optic communications depend only on the earthing wire of the high voltage transmission line. 4 refs., 8 tabs., 6 figs.

  11. 我国电烧伤治疗的成就与挑战%Achievements and challenge of treatment of electric burn over the past 50 years in China

    Institute of Scientific and Technical Information of China (English)

    孙永华

    2008-01-01

    The electric burn is a kind of special injury, in which the injured areas are not big, but deep tissues and organs are often injured, resulting in higher rates of mortality and amputation than thermal injury. In the process of management, besides the treatment for systemic and pathologic changes, wound repair is also emphasized for restoration of function. In the past 50 years, ten thound patients with electric burn were cured in our country, including hundreds of severe electric burn patients with extensive injury. Lots of operative regimes for electric burn were developed, and the scope of experimental research was broadening. As aresult, six monographs concerning electric burns were published. However, clinical management of severe electric burn to give a satisfactory result is still difficult, therefore further indepth research is necessary, especially in the field of the use of artificial skin, vessels, nerves, muscular tendon, etc. from gene and tissue engineering to improve quality of wound repair.

  12. Enhanced Model of Nonlinear Spiral High Voltage Divider

    Directory of Open Access Journals (Sweden)

    V. Panko

    2015-04-01

    Full Text Available This paper deals with the enhanced accurate DC and RF model of nonlinear spiral polysilicon voltage divider. The high resistance polysilicon divider is a sensing part of the high voltage start-up MOSFET transistor that can operate up to 700 V. This paper presents the structure of a proposed model, implemented voltage, frequency and temperature dependency, and scalability. A special attention is paid to the ability of the created model to cover the mismatch and influence of a variation of process parameters on the device characteristics. Finally, the comparison of measured data vs. simulation is presented in order to confirm the model validity and a typical application is demonstrated.

  13. Hazard classification assessment for the High Voltage Initiator

    Energy Technology Data Exchange (ETDEWEB)

    Cogan, J.D.

    1994-04-19

    An investigation was conducted to determine whether the High Voltage Initiator (Sandia p number 395710; Navy NAVSEA No. 6237177) could be assigned a Department of Transportation (DOT) hazard classification of ``IGNITERS, 1.4G, UN0325`` under Code of Federal Regulations, 49 CFR 173.101, when packaged per Mound drawing NXB911442. A hazard classification test was performed, and the test data led to a recommended hazard classification of ``IGNITERS, 1.4G, UN0325,`` based on guidance outlined in DOE Order 1540.2 and 49 CFR 173.56.

  14. The Application of Gastrocnemius Flap in Severe Electrical Burns of the Knees%腓肠肌肌瓣在修复严重膝部电烧伤中的应用

    Institute of Scientific and Technical Information of China (English)

    朱维平; 陈国华; 赵琳

    2003-01-01

    Objective To investigate the repairing methods of severe electrical burns of the knees. Methods 10pateints with severe electrical burns of the knees were enrolled in this study. After local debridement, gastrocnemius flap and netskin graft immediately. Results The entire flap survived very well with satisfactory results. Conclusion Early debridementfollowed by gastrocnemius flap and net skin graft could be simple, safe and reliable treatment strategies in the patients withsevere electrical burns of the knees.

  15. Effect of a combined continuous and intermittent transcutaneous electrical nerve stimulation on pain perception of burn patients evaluated by visual analog scale: a pilot study

    Science.gov (United States)

    Pérez-Ruvalcaba, Irma; Sánchez-Hernández, Viridiana; Mercado-Sesma, Arieh R

    2015-01-01

    Aim The aim of this study was to assess the effect of continuous and intermittent electrical transcutaneous nerve stimulation on the perception of pain in patients with burns of different types. Materials and methods A pilot study was conducted in 14 patients (age 30.9±7.5 years) with second- and third-degree burns of different types. The burn types included electrical, fire/flame, and chemical. All patients received continuous and intermittent electrical transcutaneous nerve stimulation sessions three times per week for 4 weeks. Each session had a duration of 30 minutes. A pair of electrodes were placed around the burn. The primary efficacy endpoint was the perception of pain assessed by a visual analog scale at baseline and at the 30th day. Results A significant reduction of pain perception was reported (8.0±1.7 vs 1.0±0.5; P=0.027) by all patients after electrical stimulation therapy. There were no reports of adverse events during the intervention period. Conclusion Electrical stimulation could be a potential nonpharmacological therapeutic option for pain management in burn patients. PMID:26719723

  16. Paediatric ICU burns in Finland 1994-2004.

    Science.gov (United States)

    Papp, Anthony; Rytkönen, Tanja; Koljonen, Virve; Vuola, Jyrki

    2008-05-01

    The paediatric burn population requiring intensive care in Finland has never been examined before. The aim of this study was firstly to determine the aetiology, incidence and prognosis of paediatric burns requiring intensive care in Finland and secondly to compare the possible differences between the two national burn centres. All burn patients' charts were retrospectively reviewed in two national burn centres from an 11-year-period. Patients whose ICU stay was more than 48h, were included. Forty-five children who were hospitalized in the two burn centres during the study period met the inclusion criteria. They represent 2.4% (45/1898) of all burns victims hospitalized in these burn centres during that time giving an incidence of 0.1/100,000 per year in Finland. The median age was 5 years, every third patient was 0-2 years old and 75.6% were male. Most burns were scalds (42.2%), which caused all burns (100%) in age group 0-2 years. Flame burns were most frequent (83%) in the age group 6-10 years. In the 11-16 years old patients, high voltage/electric burns caused 50% of all burns and flame the other 50%. The overall median TBSA in all burns was 26%. The median (range) hospital stay was 12 days (2-193) (0.88 days/% burned) and the median (range) ICU days was 7 (2-64) (0.29 days/%). Intubation and respirator therapy was needed in 31 (46%) patients. There were no patients who needed haemofiltration or haemodialysis and no mortality. Only six patients (13%) were treated conservatively and 39 (87%) surgically. Dressing changes under general anaesthesia were preferred in Helsinki (37 times) and especially in the paediatric hospital (32 times) compared to Kuopio (7 times). Allografts were used only in Helsinki in 4 patients whereas artificial skin was used only in Kuopio in 15 patients. The overall cost of care was very similar in both centres being 1292-1425 euros per hospital day. There were some small differences between the two burn centres in treatment policies. Most

  17. EXPERIENCE IN TREATING SECONDARY SYSTEMIC MYCOTIC INFECTION AFTER SEVERE BURNS ASSOCIATED WITH ELECTRIC INJURY

    Institute of Scientific and Technical Information of China (English)

    谢卫兴; 李秀芝

    1995-01-01

    One patient with wound surface sepsis caused by secondary pyocyanic infection after extensive burns associated with visceral injuries (peptic ulcer hemorrhage, renal insufficiency and hepatic dysfunction) and generalized candidiasis albicans was cured after anti-infection treatment with proper antibiotics, removal of the infected focus, and effective anti-fungal drugs.

  18. 电灼伤的神经系统损伤%Nervous system injury of electrical burn

    Institute of Scientific and Technical Information of China (English)

    吴远; 李光勤

    2014-01-01

    因日常生活用电越来越广泛,电灼伤的发生率逐渐上升,具有较高的致死率和致残率。神经系统损伤是电灼伤常见的并发症,主要包括周围神经系统损伤、中枢神经系统损伤。周围神经系统损伤较多见,支配区出现无力、感觉异常、感觉缺失、神经痛、反射性交感神经营养不良症等;中枢神经系统损伤包括脊髓损伤和脑神经损伤,主要表现为电休克和各种神经系统后遗症。早期出现的神经系统损伤往往能被认识并加以治疗,而晚期出现的神经系统损伤常得不到重视。%With more use of electricity in daily life,the incidence rate of electrical burn is rising gradually,and electri-cal burn has higher mortality and disability.Nervous system injury is the common complication of electric burn and mainly includes the peripheral nervous system injury and central nervous system injury.The peripheral nervous system injury is more common,and it appears weakness,paresthesia,loss of sensation,neuralgia,reflex sympathetic dystrophy in control area and so on;the central nervous system injury mainly includes the brain and spinal cord injury,mainly for electrical shock and a variety of neurologic sequelae.The early emergence of nervous system injury can often be recog-nized and treated,the late emergence of nervous system injury can often be neglected.

  19. High Voltage Performance of the Beam Screen of the LHC Injection Kicker Magnets

    CERN Document Server

    Barnes, MJ; Bregliozzi, G; Calatroni, S; Costa Pinto, P; Day, H; Ducimetière, L; Kramer, T; Namora, V; Mertens, V; Taborelli, M

    2014-01-01

    The LHC injection kicker magnets include beam screens to shield the ferrite yokes against wakefields resulting from the high intensity beam. The screening is provided by conductors lodged in the inner wall of a ceramic support tube. The design of the beam screen has been upgraded to overcome limitations and permit LHC operation with increasingly higher bunch intensity and short bunch lengths: the new design also significantly reduces the electric field associated with the screen conductors, decreasing the probability of electrical breakdown. The high voltage conditioning process for the upgraded kicker magnets is presented and discussed. In addition a test setup has been utilized to study flashover, on the inner wall of the ceramic tube, as a function of both applied voltage and vacuum pressure: results from the test setup are presented.

  20. Numerical simulation of corona-induced vibration of high voltage conductor

    Institute of Scientific and Technical Information of China (English)

    A. GOURBI; M. BRAHAMI; A. TILMATINE; P. PIROTTE

    2009-01-01

    When it rains, electric power transmission lines start vibrating due to corona effect. This type of vibration is known as "corona-induced vibration". The aim of this paper is to elaborate a mathematical model for numerical simulation of the corona-induced vibration, with consid-eration of the influence of the magnitude and the polarity of the electric field on the conductor surface. Finite element method was employed to develop the numerical model,and the finite difference method was used for the time discretisation. The moment of application of the corona-induced force is evaluated using the resultant vertical force applied to a water drop, suspended under a high voltage conductor. Some experimental results of other authors are exploited to evaluate the precision of the simulation and the validation of numerical results.

  1. Electronic Current Transducer (ECT) for high voltage dc lines

    Science.gov (United States)

    Houston, J. M.; Peters, P. H., Jr.; Summerayes, H. R., Jr.; Carlson, G. J.; Itani, A. M.

    1980-02-01

    The development of a bipolar electronic current transducer (ECT) for measuring the current in a high voltage dc (HVDC) power line at line potential is discussed. The design and construction of a free standing ECT for use on a 400 kV line having a nominal line current of 2000 A is described. Line current is measured by a 0.0001 ohm shunt whose voltage output is sampled by a 14 bit digital data link. The high voltage interface between line and ground is traversed by optical fibers which carry digital light signals as far as 300 m to a control room where the digital signal is converted back to an analog representation of the shunt voltage. Two redundant electronic and optical data links are used in the prototype. Power to operate digital and optical electronics and temperature controlling heaters at the line is supplied by a resistively and capacitively graded 10 stage cascade of ferrite core transformers located inside the hollow, SF6 filled, porcelain support insulator. The cascade is driven by a silicon controlled rectifier inverter which supplies about 100 W of power at 30 kHz.

  2. Pollution Maintenance Techniques in Coastal High Voltage Installations

    Directory of Open Access Journals (Sweden)

    E. Pyrgioti

    2011-02-01

    Full Text Available Pollution of outdoor high voltage insulators is a common problem for utilities, with a considerable impact to power system reliability. In an effort to prevent possible flashovers due to pollution, many methods have been applied, aiming to improve the insulation performance, either by suppressing the formation of surface conductivity or by increasing the possible insulation level. In the case of substations, the selection of the appropriate technique is complex due to certain issues correlated to the nature of the installation. In this paper, several techniques usually implemented by utilities, are investigated based on the experienced gained in the case of Crete, a Greek island in southern Europe, where due to the coastal development of the power system, the majority of high voltage installations are exposed to intense marine pollution. The technique of coating insulators with Room Temperature Vulcanized Silicone Rubber (RTV SIR has proved rather efficient and therefore is presented extendedly. Correlation of the material behaviour with environmental conditions is discussed and results from long term monitoring, including environmental parameters and leakage current measurements, in a 150 kV Substation are presented. It is shown that RTV SIR coatings have remarkably suppressed surface activity and that porcelain insulators exhibit different activity period when coated.

  3. A compact, all solid-state LC high voltage generator.

    Science.gov (United States)

    Fan, Xuliang; Liu, Jinliang

    2013-06-01

    LC generator is widely applied in the field of high voltage generation technology. A compact and all solid-state LC high voltage generator based on saturable pulse transformer is proposed in this paper. First, working principle of the generator is presented. Theoretical analysis and circuit simulation are used to verify the design of the generator. Experimental studies of the proposed LC generator with two-stage main energy storage capacitors are carried out. And the results show that the proposed LC generator operates as expected. When the isolation inductance is 27 μH, the output voltage is 1.9 times larger than the charging voltage on single capacitor. The multiplication of voltages is achieved. On the condition that the primary energy storage capacitor is charged to 857 V, the output voltage of the generator can reach to 59.5 kV. The step-up ratio is nearly 69. When self breakdown gas gap switch is used as main switch, the rise time of the voltage pulse on load resistor is 8.7 ns. It means that the series-wound inductance in the discharging circuit is very small in this system. This generator can be employed in two different applications.

  4. Increasing the efficiency of teaching the topic "Burns, frostbites, electric traumas" by means of modern educational technology

    Directory of Open Access Journals (Sweden)

    Nor N.N.

    2013-12-01

    Full Text Available The main objective of the work is to test and implement modern interactive methods in the field of medical education, namely the method of cooperative groups into the educational process of the Department of General Surgery of SI "DMA MH" and to determine its efficacy by the example of class on the topic "Burns, frostbites, electrical trauma. Diagnosis, first aid, medical treatment”. The method is used to find similarities in different patterns of giving medical care to patients with burns, frostbites and electric trauma. Learning activity is divided into three stages. Stage 1: the teacher divides the students into four groups and gives a task to each group. Stage 2: each group announces the results and presents them in the standardized format. After the discussion the proper decision on the common features of the first aid, treatment, and the algorithm of action is made. Stage 3: the groups share results of the previous clinical experience, sum up, solve situational tasks and tests of level III. The method of co-operative groups allows to increase the motivation of students in the learning process, causes more efficient and thorough acquiring of the material, promotes development of clinical thinking, develops the urge towards collaboration and collective responsibility, favors the development of positive personal qualities of a future professional doctor.

  5. Growth and Characterization of Single Crystalline Bi4Ge3O12 Fibers for Electrooptic High Voltage Sensors

    Directory of Open Access Journals (Sweden)

    Stephan Wildermuth

    2013-01-01

    Full Text Available The micro-pulling-down technique for crystalline fiber growth is employed to grow fibers and thin rods of bismuth germanate, Bi4Ge3O12 (BGO, for use in electrooptic high voltage sensors. The motivation is the growth of fibers that are considerably longer than the typical lengths (100–250 mm that are achieved by more conventional growth techniques like the Czochralski technique. At a given voltage (several hundred kilovolts in high voltage substation applications longer sensors result in lower electric field strengths and therefore more compact and simpler electric insulation. BGO samples with lengths up to 850 mm and thicknesses from 300 μm to 3 mm were grown. Particular challenges in the growth of BGO fibers are addressed. The relevant optical properties of the fibers are characterized, and the electrooptic response is investigated at voltages up to .

  6. Design of load-to-failure tests of high-voltage insulation breaks for ITER's cryogenic network

    CERN Document Server

    Langeslag, S A E; Aviles Santillana, I; Sgobba, S; Foussat, A

    2015-01-01

    The development of new generation superconducting magnets for fusion research, such as the ITER experiment, is largely based on coils wound with so-called cable-in-conduit conductors. The concept of the cable-in-conduit conductor is based on a direct cooling principle, by supercritical helium, flowing through the central region of the conductor, in close contact with the superconducting strands. Consequently, a direct connection exists between the electrically grounded helium coolant supply line and the highly energised magnet windings. Various insulated regions, constructed out of high-voltage insulation breaks, are put in place to isolate sectors with different electrical potential. In addition to high voltages and significant internal helium pressure, the insulation breaks will experience various mechanical forces resulting from differential thermal contraction phenomena and electro-magnetic loads. Special test equipment was designed, prepared and employed to assess the mechanical reliability of the insul...

  7. Effect of a combined continuous and intermittent transcutaneous electrical nerve stimulation on pain perception of burn patients evaluated by visual analog scale: a pilot study

    Directory of Open Access Journals (Sweden)

    Pérez-Ruvalcaba I

    2015-12-01

    Full Text Available Irma Pérez-Ruvalcaba,1 Viridiana Sánchez-Hernández,1 Arieh R Mercado-Sesma2,3 1Burn Unit, Hospital de Especialidades, Centro Médico Nacional de Occidente, Mexican Institute of Social Security, 2Health Sciences Department, Centro Universitario de Tonalá, University of Guadalajara, Guadalajara, Mexico; 3Diabetes sin Complicaciones, Zapopan, Mexico Aim: The aim of this study was to assess the effect of continuous and intermittent electrical transcutaneous nerve stimulation on the perception of pain in patients with burns of different types. Materials and methods: A pilot study was conducted in 14 patients (age 30.9±7.5 years with second- and third-degree burns of different types. The burn types included electrical, fire/flame, and chemical. All patients received continuous and intermittent electrical transcutaneous nerve stimulation sessions three times per week for 4 weeks. Each session had a duration of 30 minutes. A pair of electrodes were placed around the burn. The primary efficacy endpoint was the perception of pain assessed by a visual analog scale at baseline and at the 30th day. Results: A significant reduction of pain perception was reported (8.0±1.7 vs 1.0±0.5; P=0.027 by all patients after electrical stimulation therapy. There were no reports of adverse events during the intervention period. Conclusion: Electrical stimulation could be a potential nonpharmacological therapeutic option for pain management in burn patients. Keywords: TENS, burn pain, pain management, electrotherapy

  8. Laboratory Investigation on Lightning Flashes to High Voltage Transmission Lines%Laboratory Investigation on Lightning Flashes to High Voltage Transmission Lines

    Institute of Scientific and Technical Information of China (English)

    Thongchai Disyadej; Stanislaw Grzybowski

    2011-01-01

    This paper presents an investigation on the attractive width of high voltage transmission lines to lightning strikes. In order to design the optimal lightning protection, the estimated number of lightning flashes on the line, which is based on its attractive width, needs to be determined. The investigation was performed using experiments with model tests at the Mississippi State University High Voltage Laboratory. For laboratory experiments, a total of 2,100 negative and positive switching impulse voltages were applied to transmission line models from a conducting rod, which represented a lightning downward leader. Different tested models of transmission lines on a scale of 1:100 were used. The effects of overhead ground wires, phase conductors, tower structures, and the magnitude and polarity of lightning strokes were also studied. The attractive width increased gradually with the height of overhead ground wires and towers as well as the magnitude of the lightning stroke current. Impulse polarity had an impact on the at- tractive width, and the attractive width for negative polarity was larger than that {or positive polarity. The taller tower had more effect on flash distribution to transmission lines than the shorter one. The experimental results agree with the actual transmission line observations published in literature. The new expressions for the attractive width of transmission lines, based on the experimental results, were established. The accurate estimation of the attractive width can help electric power utilities plan transmission systems reliably and economically. The detailed description of the back- ground problem, proposed method, experimental results, and analysis are presented in this paper.

  9. High Voltage EEE Parts for EMA/EHA Applications on Manned Launch Vehicles

    Science.gov (United States)

    Griffin, Trent; Young, David

    2011-01-01

    The objective of this paper is an assessment of high voltage electronic components required for high horsepower electric thrust vector control (TVC) systems for human spaceflight launch critical application. The scope consists of creating of a database of available Grade 1 electrical, electronic and electromechanical (EEE) parts suited to this application, a qualification path for potential non-Grade 1 EEE parts that could be used in these designs, and pathfinder testing to validate aspects of the proposed qualification plan. Advances in the state of the art in high power electric power systems enable high horsepower electric actuators, such as the electromechnical actuator (EMA) and the electro-hydrostatic actuator (EHA), to be used in launch vehicle TVC systems, dramaticly reducing weight, complexity and operating costs. Designs typically use high voltage insulated gate bipolar transistors (HV-IGBT). However, no Grade 1 HV-IGBT exists and it is unlikely that market factors alone will produce such high quality parts. Furthermore, the perception of risk, the lack of qualification methodoloy, the absence of manned space flight heritage and other barriers impede the adoption of commercial grade parts onto the critical path. The method of approach is to identify high voltage electronic component types and key parameters for parts currently used in high horsepower EMA/EHA applications, to search for higher quality substitutes and custom manufacturers, to create a database for these parts, and then to explore ways to qualify these parts for use in human spaceflight launch critical application, including grossly derating and possibly treating hybrid parts as modules. This effort is ongoing, but results thus far include identification of over 60 HV-IGBT from four manufacturers, including some with a high reliability process flow. Voltage ranges for HV-IGBT have been identified, as has screening tests used to characterize HV-IGBT. BSI BS ISO 21350 Space systems Off

  10. Assessment of Human Exposure to Magnetic Field from Overhead High Voltage Transmission Lines in a City in South Western Nigeria

    OpenAIRE

    Ponnle Akinlolu; Adedeji Kazeem

    2015-01-01

    The increase in electricity consumption, population, and land use has now forced high voltage transmission lines (HVTLs) either to pass or be installed around or through urban cities. This increases the level of human exposure to electromagnetic field radiation as this field produced around the HVTLs extends outwards covering some distance. This may cause a number of health hazards. It is even dangerous to a human who touch any metallic object in proximity of the HVTL, as it may have an appre...

  11. Electromagnetic compatibility between secondary and high voltage circuits; Compatibilidade eletromagnetica entre circuitos secundarios e de alta tensao

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Mario Fabiano [Pontificia Univ. Catolica de Minas Gerais, Belo Horizonte, MG (Brazil)

    1997-11-01

    Electromagnetic fields generated by high voltage circuits may affect the performance of sensible loads in an electric power substation. In order to reduce such interferences, and guarantee the adequate performance of the equipment, this work proposes some measures which may be applied to the project during the installation phase, such as the equalization of high frequency power, and the utilization of protective equipment as well as the integration of grounding systems 9 refs., 3 figs.

  12. Impact of high energy electron irradiation on high voltage Ni/4H-SiC Schottky diodes

    Science.gov (United States)

    Kozlovski, V. V.; Lebedev, A. A.; Levinshtein, M. E.; Rumyantsev, S. L.; Palmour, J. W.

    2017-02-01

    We report the results of the high energy (0.9 MeV) electron irradiation impact on the electrical properties of high voltage Ni/4H-SiC Schottky diodes. Within the range of the irradiation dose from 0.2 × 1016 cm-2 to 7 × 1016 cm-2, electron irradiation led to 6 orders of magnitude increase in the base resistance, appearance of slow relaxation processes at pico-ampere current range, and increase in the ideality factor.

  13. 30 CFR 77.704-1 - Work on high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Work on high-voltage lines. 77.704-1 Section 77... MINES Grounding § 77.704-1 Work on high-voltage lines. (a) No high-voltage line shall be regarded as... provided in § 77.103) that such high-voltage line has been deenergized and grounded. Such qualified...

  14. Assessment of Electromagnetic Fields around High Voltage Power Supply in Hamadan Hospital Wards

    Directory of Open Access Journals (Sweden)

    Nima Rostampour

    2012-10-01

    Full Text Available Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 Background and Objectives: Biological effects of non-ionizing radiation on the body of living organisms have been studied by researchers in recent years. High Voltage medical equipments are one of the sources generating electromagnetic fields. The electromagnetic field intensity of the medical equipment installed at Hamadan hospitals and the potential hazards were investigated. The main purpose of this study was to determine the intensity of the electromagnetic field around high voltage power supplies in radiology ward of the Hamadan hospitals. Materials and Methods: This was a cross-sectional study and we investigated the electromagnetic fields intensity around high voltage power supplies at Hamadan hospital wards. All measurements were performed using a calibrated Tesla-meter (HI-3603. The measurements were conducted at a range of distances varying from 25 cm to 3 m around the supporting high voltage power supply. Results: We found that the maximum intensity of the magnetic and electric fields at a distance of less than 1 m around the high voltage power supply was 29.625±5.738 mGauss and 25.17±0.92 V/m respectively, which is less than the safe amounts recommended by the ICNIRP for occupational exposure (5000 mG and 10000 V/m and even for public exposure (1000 mG and and 5000 V/m. The minimum intensity of EM fields for a less than 3 m distance was found to be 0.1±0.005 mGauss, which relates to a CT-scanner system installed at Farshchian hospital. Among the whole equipments evaluated in the current survey, the most intense magnetic and electric field was found to be for imaging technician office, which was 3.050±0.004 mGauss and 128.88±0.05 V/m respectively; it is lower than the tolerances recommended by the ICNIRP. Conclusion: According to our results, it seems that the EM field occupational exposure for radiation workers working at Hamadan hospitals does not exceed

  15. 30 CFR 75.705-1 - Work on high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Work on high-voltage lines. 75.705-1 Section 75... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.705-1 Work on high-voltage lines. (a) Section 75.705 specifically prohibits work on energized high-voltage lines underground;...

  16. 30 CFR 77.807-3 - Movement of equipment; minimum distance from high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... high-voltage lines. 77.807-3 Section 77.807-3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.807-3 Movement of equipment; minimum distance from high-voltage lines. When any part of any equipment operated on the surface of...

  17. 30 CFR 75.705-2 - Repairs to energized surface high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Repairs to energized surface high-voltage lines... Repairs to energized surface high-voltage lines. An energized high-voltage surface line may be repaired... on power circuits with a phase-to-phase nominal voltage no greater than 15,000 volts; (3)...

  18. 30 CFR 75.705-10 - Tying into energized high-voltage surface circuits.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tying into energized high-voltage surface....705-10 Tying into energized high-voltage surface circuits. If the work of forming an additional circuit by tying into an energized high-voltage surface line is performed from the ground, any...

  19. 21 CFR 892.1700 - Diagnostic x-ray high voltage generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic x-ray high voltage generator. 892.1700... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1700 Diagnostic x-ray high voltage generator. (a) Identification. A diagnostic x-ray high voltage generator is a device that is intended...

  20. 30 CFR 77.704-2 - Repairs to energized high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Repairs to energized high-voltage lines. 77.704... UNDERGROUND COAL MINES Grounding § 77.704-2 Repairs to energized high-voltage lines. An energized high-voltage... repairs will be performed on power circuits with a phase-to-phase nominal voltage no greater than...

  1. 30 CFR 75.811 - High-voltage underground equipment; grounding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage underground equipment; grounding... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.811 High-voltage underground equipment; grounding. Frames, supporting structures...

  2. 30 CFR 77.704-10 - Tying into energized high-voltage surface circuits.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tying into energized high-voltage surface... AREAS OF UNDERGROUND COAL MINES Grounding § 77.704-10 Tying into energized high-voltage surface circuits. If the work of forming an additional circuit by tying into an energized high-voltage surface line...

  3. 30 CFR 75.800 - High-voltage circuits; circuit breakers.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage circuits; circuit breakers. 75.800... § 75.800 High-voltage circuits; circuit breakers. High-voltage circuits entering the underground area of any coal mine shall be protected by suitable circuit breakers of adequate interrupting...

  4. Surface dynamics of amorphous polymers used for high-voltage insulators.

    Science.gov (United States)

    Shemella, Philip T; Laino, Teodoro; Fritz, Oliver; Curioni, Alessandro

    2011-11-24

    Amorphous siloxane polymers are the backbone of high-voltage insulation materials. The natural hydrophobicity of their surface is a necessary property for avoiding leakage currents and dielectric breakdown. As these surfaces are exposed to the environment, electrical discharges or strong mechanical impact can temporarily destroy their water-repellent properties. After such events, however, a self-healing process sets in and restores the original hydrophobicity within some hours. In the present study, we investigate possible mechanisms of this restoration process. Using large-scale, all-atom molecular dynamics simulations, we show that molecules on the material surface have augmented motion that allows them to rearrange with a net polarization. The overall surface region has a net orientation that contributes to hydrophobicity, and charged groups that are placed at the surface migrate inward, away from the vacuum interface and into the bulk-like region. Our simulations provide insight into the mechanisms for hydrophobic self-recovery that repair material strength and functionality and suggest material compositions for future high-voltage insulators.

  5. Design issues of the High Voltage platform and feedthrough for the ITER NBI Ion Source

    Energy Technology Data Exchange (ETDEWEB)

    Boldrin, M. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy)], E-mail: marco.boldrin@igi.cnr.it; Palma, M. Dalla; Milani, F. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy)

    2009-06-15

    In the ITER heating Neutral Beam Injector (NBI), a High Voltage air-insulated platform (named High Voltage Deck, HVD) will be installed to host the Ion Source and Extractor Power supply system and associated diagnostics referred to -1 MV DC potential. All power and control cables are routed from the HVD via a feedthrough (HV bushing) to the gas insulated transmission line which feeds the Injector. The paper focuses on insulation and mechanical issues for both HVD and HV bushing which are very special components, far from the present industrial standards as far as voltage (-1 MV DC) and dimensions are concerned. For this purpose, a preliminary design of the HVD has been carried out as concerns the mechanical structure and external shield. Then, the structure has been verified with a seismic analysis applying the seismic load excitation specified for the ITER construction site (Cadarache) and carrying out verifications according to relevant international standards. As regards the HV bushing design, proposals for the complex inner conductor structure and for interfaces to the HVD and transmission line are outlined; alternative installation layouts (aside or underneath the HVD) are compared from both mechanical and electrical points of view.

  6. Job Grading Standard for Electrician (High Voltage) WG-2810.

    Science.gov (United States)

    Civil Service Commission, Washington, DC. Bureau of Policies and Standards.

    The standard covers nonsupervisory work involved in installation, test, repair, and maintenance of electric power plant and/or overhead and underground primary electrical distribution systems. These jobs require knowledge and application of electrical principles, procedures, materials, and safety standards governing work on electrical systems…

  7. High Voltage Installation of PS Linac 1 Preinjector

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    The high-voltage installation of the linac 1 preinjector in its house-sized Faraday cage. Originally driven by a 520 kV Cockcroft-Walton generator, at the time of this picture the HV came from a 520 kV SAMES generator. The column in the front carries a capacitor. The cubicle in the right background is the electronics platform (see 7403120). The round structure at left houses the ion source, from where the protons (and sometimes other ions), electrostatically accelerated to 520 keV, enter the Alvarez structure of linac 1, to be accelerated to 50 MeV. Jean-Luc Vallet is busy with servicing the installation. See also 7403064X, 7403066X.

  8. Digital measurement system for the LHC klystron high voltage modulator.

    CERN Document Server

    Mikkelsen, Anders

    Accelerating voltage in the Large Hadron Collider (LHC) is created by a means of 16 superconducting standing wave RF cavities, each fed by a 400MHz/300kW continuous wave klystron amplifier. Part of the upgrade program for the LHC long shutdown one is to replace the obsolete analogue current and voltage measurement circuitry located in the high voltage bunkers by a new, digital system, using ADCs and optical fibres. A digital measurement card is implemented and integrated into the current HV modulator oil tank (floating at -58kV) and interfaced to the existing digital VME boards collecting the data for several klystrons at the ground potential. Measured signals are stored for the logging, diagnostics and post-mortem analysis purposes.

  9. Evolution of recrystallization textures in high voltage aluminum capacitor foils

    Institute of Scientific and Technical Information of China (English)

    刘楚明; 张新明; 周鸿章; 陈志永; 邓运来; 周卓平

    2001-01-01

    The evolution of recrystallization textures in high voltage aluminum capacitor foils which are produced with a high level of cold reduction was tracked by analysis of microstructure and crystallographic texture. The results show that the deformation textures are mainly composed of S-orientation, Cu-orientation and a little Bs-orientation. During the low temperature stages of final annealing, the iron precipitates first along the sub-grain boundaries, and the Fe concentration in the matrix becomes low. Then, the cube grains nucleate preferably into the sub-grains. At high temperature stages, the cube nuclei can grow preferably because of their 40°〈111〉 orientation relationship to the S orientation, the main component of the rolling texture. Finally, the cube texture is sharply strong and the R orientation is very weak in the foils.

  10. High-voltage, low-inductance gas switch

    Science.gov (United States)

    Gruner, Frederick R.; Stygar, William A.

    2016-03-22

    A low-inductance, air-insulated gas switch uses a de-enhanced annular trigger ring disposed between two opposing high voltage electrodes. The switch is DC chargeable to 200 kilovolts or more, triggerable, has low jitter (5 ns or less), has pre-fire and no-fire rates of no more than one in 10,000 shots, and has a lifetime of greater than 100,000 shots. Importantly, the switch also has a low inductance (less than 60 nH) and the ability to conduct currents with less than 100 ns rise times. The switch can be used with linear transformer drives or other pulsed-power systems.

  11. Planar LTCC transformers for high voltage flyback converters.

    Energy Technology Data Exchange (ETDEWEB)

    Schofield, Daryl (NASCENT Technology Inc. , Watertown, SD); Schare, Joshua M.; Glass, Sarah Jill; Roesler, Alexander William; Ewsuk, Kevin Gregory; Slama, George (NASCENT Technology Inc. , Watertown, SD); Abel, Dave (NASCENT Technology Inc. , Watertown, SD)

    2007-06-01

    This paper discusses the design and use of low-temperature (850 C to 950 C) co-fired ceramic (LTCC) planar magnetic flyback transformers for applications that require conversion of a low voltage to high voltage (> 100V) with significant volumetric constraints. Measured performance and modeling results for multiple designs showed that the LTCC flyback transformer design and construction imposes serious limitations on the achievable coupling and significantly impacts the transformer performance and output voltage. This paper discusses the impact of various design factors that can provide improved performance by increasing transformer coupling and output voltage. The experiments performed on prototype units demonstrated LTCC transformer designs capable of greater than 2 kV output. Finally, the work investigated the effect of the LTCC microstructure on transformer insulation. Although this paper focuses on generating voltages in the kV range, the experimental characterization and discussion presented in this work applies to designs requiring lower voltage.

  12. An ultra-low noise, high-voltage piezo driver

    CERN Document Server

    Pisenti, N C; Reschovsky, B J; Barker, D S; Campbell, G K

    2016-01-01

    We present an ultra-low noise, high-voltage driver suited for use with piezoelectric actuators and other low-current applications. The architecture uses a flyback switching regulator to generate up to 250V in our current design, with an output of 1 kV or more possible with small modifications. A high slew-rate op-amp suppresses the residual switching noise, yielding a total RMS noise of $\\approx 100\\mu$V (1 Hz--100 kHz). A low-voltage ($\\pm 10$V), high bandwidth signal can be summed with unity gain directly onto the output, making the driver well-suited for closed-loop feedback applications. Digital control enables both repeatable setpoints and sophisticated control logic, and the circuit consumes less than 150mA at $\\pm 15$V.

  13. High-Voltage, Low-Power BNC Feedthrough Terminator

    Science.gov (United States)

    Bearden, Douglas

    2012-01-01

    This innovation is a high-voltage, lowpower BNC (Bayonet Neill-Concelman) feedthrough that enables the user to terminate an instrumentation cable properly while connected to a high voltage, without the use of a voltage divider. This feedthrough is low power, which will not load the source, and will properly terminate the instrumentation cable to the instrumentation, even if the cable impedance is not constant. The Space Shuttle Program had a requirement to measure voltage transients on the orbiter bus through the Ground Lightning Measurement System (GLMS). This measurement has a bandwidth requirement of 1 MHz. The GLMS voltage measurement is connected to the orbiter through a DC panel. The DC panel is connected to the bus through a nonuniform cable that is approximately 75 ft (approximately equal to 23 m) long. A 15-ft (approximately equal to 5-m), 50-ohm triaxial cable is connected between the DC panel and the digitizer. Based on calculations and simulations, cable resonances and reflections due to mismatched impedances of the cable connecting the orbiter bus and the digitizer causes the output not to reflect accurately what is on the bus. A voltage divider at the DC panel, and terminating the 50-ohm cable properly, would eliminate this issue. Due to implementation issues, an alternative design was needed to terminate the cable properly without the use of a voltage divider. Analysis shows how the cable resonances and reflections due to the mismatched impedances of the cable connecting the orbiter bus and the digitizer causes the output not to reflect accurately what is on the bus. After simulating a dampening circuit located at the digitizer, simulations were performed to show how the cable resonances were dampened and the accuracy was improved significantly. Test cables built to verify simulations were accurate. Since the dampening circuit is low power, it can be packaged in a BNC feedthrough.

  14. Covering sleeves can shield the high-voltage coils from lead chatter in an integrated bipolar ICD lead.

    Science.gov (United States)

    Cooper, Joshua M; Sauer, William H; Garcia, Fermin C; Krautkramer, Michael J; Verdino, Ralph J

    2007-02-01

    Integrated bipolar implantable cardioverter-defibrillator (ICD) leads use the distal high-voltage coil as both the ventricular sensing anode and the distal shocking electrode. Mechanical interactions between the distal ICD coil and other intracardiac leads have been reported to result in electrical oversensing and inappropriate ICD therapies. We sought to determine whether covering sleeves over the high-voltage coils of an integrated bipolar ICD lead could prevent sensed artefact from mechanical lead interactions. Endotak Reliance 0157 and Endotak Reliance-G 0185 leads, the latter with expanded polytetrafluoroethylene (ePTFE) sleeves covering the high-voltage coils, were connected to ICD generators and the leads were submerged in saline. Device programmers were used to communicate with the ICD generators, providing real-time electrogram recording throughout testing. A series of mechanical interactions were performed with the ICD leads, including sliding and striking each distal coil against metal and non-metal components of other ICD and pacemaker leads. All direct metal-metal interactions resulted in sensed electrical artefact, including interactions between the bare ICD coil and another bare ICD coil or metal pacemaker ring. Identical mechanical interactions where metal-metal contact was prevented due to an interposed ePTFE covering sleeve were electrically silent with no sensed artefact. A covering sleeve over the distal high-voltage coil of an integrated bipolar ICD lead can mechanically shield the lead from metal-metal interactions, which might otherwise result in sensed artefact and inappropriate ICD therapies or withholding of pacing output. This finding has implications for lead selection when a new ICD lead is to be implanted adjacent to abandoned intracardiac leads or lead fragments.

  15. Long term outcome and follow up of electrical injury

    Institute of Scientific and Technical Information of China (English)

    Hamid Karimi; Mahnoush Momeni; Mahtab Vasigh

    2015-01-01

    Objective: To evaluate the outcome of electrical burn on a patient's life performance and the disability induced by this type of injury.Methods:This study is a prospective 6 years descriptive study. The injured patients admitted to our center between 2006 and 2008 were followed for 6 years to estimate the ability of their life and job performance after the injury.Results:In the patients, 96.8% were male. The mean age of patients was 27.9 years. 73.9% of those injuries were occupational injuries. 86.5% were pure electrical injuries. 81% of patients went back to their previous job within a 5-6 year period. Only 5% had the ability to perform their usual daily activities-these patients needed financial support from family, insurance companies and government. Unfortunately 6.3% were totally disabled and needed complete help even for their minor natural needs. These patients are young and probably have a long-term life expectancy and would have a huge financial impact on the government and society. The mean length of hospital stay was 17.7 d. The mean total body surface area burned was 13.3%±11.5%. We could see an association between high voltage burns and falling down (P=0.005). High voltage burns needed longer periods away from work (197 d) in comparison with low voltage injuries (145.8 d) (P=0.003). Conclusions: High voltage electrical burns are severe, needing more flap repairs and/or amputations and cause longer periods away from work.

  16. TCAD simulations of High-Voltage-CMOS Pixel structures for the CLIC vertex detector

    CERN Document Server

    Buckland, Matthew Daniel

    2016-01-01

    The requirements for precision physics and the experimental conditions at CLIC result in stringent constraints for the vertex detector. Capacitively coupled active pixel sensors with 25 μm pitch implemented in a commercial 180 nm High-Voltage CMOS (HV-CMOS) process are currently under study as a candidate technology for the CLIC vertex detector. Laboratory calibration measurements and beam tests with prototypes are complemented by detailed TCAD and electronic circuit simulations, aiming for a comprehensive understanding of the signal formation in the HV-CMOS sensors and subsequent readout stages. In this note 2D and 3D TCAD simulation results of the prototype sensor, the Capacitively Coupled Pixel Detector version three (CCPDv3), will be presented. These include the electric field distribution, leakage current, well capacitance, transient response to minimum ionising particles and charge-collection.

  17. Initiation of vacuum insulator surface high-voltage flashover with electrons produced by laser illumination

    Science.gov (United States)

    Krasik, Ya. E.; Leopold, J. G.

    2015-08-01

    In this paper, experiments are described in which cylindrical vacuum insulator samples and samples inclined at 45° relative to the cathode were stressed by microsecond timescale high-voltage pulses and illuminated by focused UV laser beam pulses. In these experiments, we were able to distinguish between flashover initiated by the laser producing only photo-electrons and when plasma is formed. It was shown that flashover is predominantly initiated near the cathode triple junction. Even dense plasma formed near the anode triple junction does not necessarily lead to vacuum surface flashover. The experimental results directly confirm our conjecture that insulator surface breakdown can be avoided by preventing its initiation [J. G. Leopold et al., Phys. Rev. ST Accel. Beams 10, 060401 (2007)] and complement our previous experimental results [J. Z. Gleizer et al., IEEE Trans. Dielectr. Electr. Insul. 21, 2394 (2014) and J. Z. Gleizer et al., J. Appl. Phys. 117, 073301 (2015)].

  18. Initiation of vacuum insulator surface high-voltage flashover with electrons produced by laser illumination

    Energy Technology Data Exchange (ETDEWEB)

    Krasik, Ya. E.; Leopold, J. G. [Physics Department, Technion, Haifa 32000 (Israel)

    2015-08-15

    In this paper, experiments are described in which cylindrical vacuum insulator samples and samples inclined at 45° relative to the cathode were stressed by microsecond timescale high-voltage pulses and illuminated by focused UV laser beam pulses. In these experiments, we were able to distinguish between flashover initiated by the laser producing only photo-electrons and when plasma is formed. It was shown that flashover is predominantly initiated near the cathode triple junction. Even dense plasma formed near the anode triple junction does not necessarily lead to vacuum surface flashover. The experimental results directly confirm our conjecture that insulator surface breakdown can be avoided by preventing its initiation [J. G. Leopold et al., Phys. Rev. ST Accel. Beams 10, 060401 (2007)] and complement our previous experimental results [J. Z. Gleizer et al., IEEE Trans. Dielectr. Electr. Insul. 21, 2394 (2014) and J. Z. Gleizer et al., J. Appl. Phys. 117, 073301 (2015)].

  19. SOFT-SWITCHED HIGH STEP-UP DC-DC CONVERTER WITH HIGH VOLTAGE GAIN

    Directory of Open Access Journals (Sweden)

    J.C. PAUL IMMANUEL

    2013-04-01

    Full Text Available This paper presents a new design of soft switched high step-up dc-dc converter with high voltage gain which is suitable for high power applications such as Uninterruptible Power System (UPS, Photo Voltaic system and hybrid electric vehicles. The emergence of this front-end converter is to improve the shape of active input current given to the system. This converter proposes Soft-Switching technique to achieve ZVS turn on of active switches and ZCS turn off of diodes using Lr - Cr resonance in the auxiliary circuit. Therefore reduces the switching losses. Comparatively the voltage conversion ratio of this converter is higher when compared with the ordinary boost converter. Hence the voltage gain of this converter is also higher. A simulation platform is created using MATLAB which illustrates the ZVS and ZCS operation of the switches and diodes. Open loop and closed loop controlled converter systems are modelled and simulated.

  20. High voltage power supplies for ITER RF heating and current drive systems

    Energy Technology Data Exchange (ETDEWEB)

    Gassmann, T., E-mail: thibault.gassmann@iter.org [ITER Organization, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Arambhadiya, B.; Beaumont, B. [ITER Organization, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Baruah, U.K. [Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar 382428 (India); Bonicelli, T. [Fusion For Energy, C/3 Josep Pla 2, Torres Diagonal Litoral-B3, E-08019 Barcelona (Spain); Darbos, C.; Purohit, D.; Decamps, H. [ITER Organization, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Albajar, F. [Fusion For Energy, C/3 Josep Pla 2, Torres Diagonal Litoral-B3, E-08019 Barcelona (Spain); Gandini, F.; Henderson, M.; Kazarian, F.; Lamalle, P.U.; Omori, T. [ITER Organization, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Parmar, D.; Patel, A. [Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar 382428 (India); Rathi, D. [ITER Organization, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Singh, N.P. [Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar 382428 (India)

    2011-10-15

    The RF heating and current drive (H and CD) systems to be installed for the ITER fusion machine are the electron cyclotron (EC), ion cyclotron (IC) and, although not in the first phase of the project, lower hybrid (LH). These systems require high voltage, high current power supplies (HVPS) in CW operation. These HVPS should deliver around 50 MW electrical power to each of the RF H and CD systems with stringent requirements in terms of accuracy, voltage ripple, response time, turn off time and fault energy. The PSM (Pulse Step Modulation) technology has demonstrated over the past 20 years its ability to fulfill these requirements in many industrial facilities and other fusion reactors and has therefore been chosen as reference design for the IC and EC HVPS systems. This paper describes the technical specifications, including interfaces, the resulting constraints on the design, the conceptual design proposed for ITER EC and IC HVPS systems and the current status.

  1. Experimental modeling of high-voltage corona discharge using design of experiments

    Institute of Scientific and Technical Information of China (English)

    Rezzouga M; Tilmatine A; Gouri R; Medics K; Dascalescu L

    2007-01-01

    Many studies,both experimental and numerical,were devoted to the electric current of corona discharge and some mathematical models were proposed to express it.As it depends on several parameters,it is difficult to find a theoretical or an experimental formula,which considers all the factors.So we opted for the methodology of experimental designs,also called Tagushi's methodology,which represents a powerful tool generally employed when the process has many factors to consider.The objective of this paper is to model current using this experimental methodology.The factors considered were geometrical factors (interelectrode interval,surface of the grounded plane electrode,curvature radius of the point electrode),climatic factors (temperature and relative humidity),and applied high voltage.Results of experiments made it possible to obtain mathematical models and to analyse the interactions between all factors.

  2. Electrooptic Methods for Measurement of Small DC Currents at High Voltage Level

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Beatty, Neville; Skilbreid, Asbjørn Ottar

    1989-01-01

    . The measuring methods can be used both for development and supervision of electrical insulating systems. For DC measurements a system wherein the voltage is applied (across the Pockels cell) not directly but via an electrooptic circuit was developed. This circuit periodically inverts the polarity of the voltage...... fibre to an electrooptic converter. Second, by use of an electronic circuit the measured signal can be converted into a modulated frequency form for transmission along an optical fibre. These systems are described, measurement results are presented and improvements to be made in the future are outlined...... across the cell, effectively applying a square wave voltage with amplitude equal to the DC voltage to be measured. The switching circuit is based around two high voltage transistors TA, TB, with the Pockels cell electrodes being each connected to one of the transistor collectors. The transistor...

  3. High Voltage Li-Ion Battery Using Exfoliated Graphite/Graphene Nanosheets Anode.

    Science.gov (United States)

    Agostini, Marco; Brutti, Sergio; Hassoun, Jusef

    2016-05-04

    The achievement of a new generation of lithium-ion battery, suitable for a continuously growing consumer electronic and sustainable electric vehicle markets, requires the development of new, low-cost, and highly performing materials. Herein, we propose a new and efficient lithium-ion battery obtained by coupling exfoliated graphite/graphene nanosheets (EGNs) anode and high-voltage, spinel-structure cathode. The anode shows a capacity exceeding by 40% that ascribed to commercial graphite in lithium half-cell, at very high C-rate, due to its particular structure and morphology as demonstrated by X-ray diffraction (XRD), Raman spectroscopy, scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The Li-ion battery reveals excellent efficiency and cycle life, extending up to 150 cycles, as well as an estimated practical energy density of about 260 Wh kg(-1), that is, a value well exceeding the one associated with the present-state Li-ion battery.

  4. High-voltage cable insulation online monitoring in coal mine based on pattern recognition

    Science.gov (United States)

    Zhao, Yongmei; Li, Junfeng; Wu, Lingjie; Wang, Yanwen

    2017-03-01

    The single-phase grounding fault is the main electrical fault types of the mine power grid. A new cable insulation online monitoring based on pattern recognition is proposed, in case single-phase grounding fault in coal mine. Firstly, using the pattern recognition method, the insulation state of the cable is divided into three types: "good insulation" and "insulation decline symmetrically" and "insulation decline asymmetrically". Then the cables with "insulation decline asymmetrically" can be further analysed and calculated and its insulation parameter value can be determined. The algorithm is simulated and verified. Simulation result shows that: The zero-sequence voltage and each phase voltage and the zero-sequence current of each cable are taken in the coal mine high-voltage system, and the insulation parameter value of each cable can be calculated accurately by using the pattern recognition method.

  5. Frequency-Domain Maximum-Likelihood Estimation of High-Voltage Pulse Transformer Model Parameters

    CERN Document Server

    Aguglia, D

    2014-01-01

    This paper presents an offline frequency-domain nonlinear and stochastic identification method for equivalent model parameter estimation of high-voltage pulse transformers. Such kinds of transformers are widely used in the pulsed-power domain, and the difficulty in deriving pulsed-power converter optimal control strategies is directly linked to the accuracy of the equivalent circuit parameters. These components require models which take into account electric fields energies represented by stray capacitance in the equivalent circuit. These capacitive elements must be accurately identified, since they greatly influence the general converter performances. A nonlinear frequency-based identification method, based on maximum-likelihood estimation, is presented, and a sensitivity analysis of the best experimental test to be considered is carried out. The procedure takes into account magnetic saturation and skin effects occurring in the windings during the frequency tests. The presented method is validated by experim...

  6. Quantum Mechanical Analysis of GaN Nanowire Transistor for High Voltage Applications

    Directory of Open Access Journals (Sweden)

    Neel Chatterjee

    2016-12-01

    Full Text Available The paper presents the quantum mechanical analysis of Gallium Nitride nanowire transistor. The effect of high k gate dielectric and different gate metals on the electrical characteristics of the device is studied. Nanowire width has been reduced to have a proper control on the device characteristics at reduced gate length. A high value of drain current is obtained at gate length of 10 nm and nanowire radius equal to 10 nm, is obtained. Also high voltage operation of the device upto 40 volts has been shown. A flatter transconductance curve is obtained which shows the linearity of the device. The results obtained are comparable with the experimental and simulated data reported in literature

  7. The world's first high voltage GaN-on-Diamond power semiconductor devices

    Science.gov (United States)

    Baltynov, Turar; Unni, Vineet; Narayanan, E. M. Sankara

    2016-11-01

    This paper presents the detailed fabrication method and extensive electrical characterisation results of the first-ever demonstrated high voltage GaN power semiconductor devices on CVD Diamond substrate. Fabricated circular GaN-on-Diamond HEMTs with gate-to-drain drift length of 17 μm and source field plate length of 3 μm show an off-state breakdown voltage of ∼1100 V. Temperature characterisation of capacitance-voltage characteristics and on-state characteristics provides insight on the temperature dependence of key parameters such as threshold voltage, 2DEG sheet carrier concentration, specific on-state resistance, and drain saturation current in the fabricated devices.

  8. Manufacture and mechanical characterisation of high voltage insulation for superconducting busbars - (Part 1) Materials selection and development

    Science.gov (United States)

    Clayton, N.; Crouchen, M.; Devred, A.; Evans, D.; Gung, C.-Y.; Lathwell, I.

    2017-04-01

    It is planned that the high voltage electrical insulation on the ITER feeder busbars will consist of interleaved layers of epoxy resin pre-impregnated glass tapes ('pre-preg') and polyimide. In addition to its electrical insulation function, the busbar insulation must have adequate mechanical properties to sustain the loads imposed on it during ITER magnet operation. This paper reports an investigation into suitable materials to manufacture the high voltage insulation for the ITER superconducting busbars and pipework. An R&D programme was undertaken in order to identify suitable pre-preg and polyimide materials from a range of suppliers. Pre-preg materials were obtained from 3 suppliers and used with Kapton HN, to make mouldings using the desired insulation architecture. Two main processing routes for pre-pregs have been investigated, namely vacuum bag processing (out of autoclave processing) and processing using a material with a high coefficient of thermal expansion (silicone rubber), to apply the compaction pressure on the insulation. Insulation should have adequate mechanical properties to cope with the stresses induced by the operating environment and a low void content necessary in a high voltage application. The quality of the mouldings was assessed by mechanical testing at 77 K and by the measurement of the void content.

  9. Fault detection on the Large Hadron Collider at CERN: design, simulation and realization of a High Voltage Pulse Generator

    CERN Document Server

    Cavicchioli, C; Biagi, E; Bozzini, D

    2007-01-01

    This project was developed inside the Quality Assurance Plan (ELQA) of the LHC. The superconducting circuits of the collider show a great complexity concerning the control system, because of various reasons: the tunnel is placed around 50 to 175 m underground, the circuits work at temperatures of 1.9 K, all the structure should be perfectly aligned and the electronic part has considerable dimensions. To maximize the running time of the collider, it is necessary to develop methods for the diagnostic of defects and for the precise localization of the segment of the accelerator that contains the fault. From my studies it emerged that a possible way to localize electrical faults in the LHC superconducting circuits is to combine the use of time domain reflectometry methods and high voltage pulses. Therefore, I have designed and realized a high voltage pulse generator that will be an important instrument for the fault location among the accelerator.

  10. First test of a high voltage feedthrough for liquid Argon TPCs connected to a 300 kV power supply

    CERN Document Server

    Cantini, C; Bueno, L Molina; Murphy, S; Radics, B; Regenfus, C; Rigaut, Y-A; Rubbia, A; Sergiampietri, F; Viant, T; Wu, S

    2016-01-01

    Voltages above a hundred kilo-volt will be required to generate the drift field of future very large liquid Argon Time Projection Chambers. The most delicate component is the feedthrough whose role is to safely deliver the very high voltage to the cathode through the thick insulating walls of the cryostat without compromising the purity of the argon inside. This requires a feedthrough that is typically meters long and carefully designed to be vacuum tight and have small heat input. Furthermore, all materials should be carefully chosen to allow operation in cryogenic conditions. In addition, electric fields in liquid argon should be kept below a threshold to reduce risks of discharges. The combination of all above requirements represents significant challenges from the design and manufacturing perspective. In this paper, we report on the successful operation of a feedthrough satisfying all the above requirements. The details of the feedthrough design and its manufacturing steps are provided. Very high voltages...

  11. High voltage systems (tube-type microwave)/low voltage system (solid-state microwave) power distribution

    Science.gov (United States)

    Nussberger, A. A.; Woodcock, G. R.

    1980-01-01

    SPS satellite power distribution systems are described. The reference Satellite Power System (SPS) concept utilizes high-voltage klystrons to convert the onboard satellite power from dc to RF for transmission to the ground receiving station. The solar array generates this required high voltage and the power is delivered to the klystrons through a power distribution subsystem. An array switching of solar cell submodules is used to maintain bus voltage regulation. Individual klystron dc voltage conversion is performed by centralized converters. The on-board data processing system performs the necessary switching of submodules to maintain voltage regulation. Electrical power output from the solar panels is fed via switch gears into feeder buses and then into main distribution buses to the antenna. Power also is distributed to batteries so that critical functions can be provided through solar eclipses.

  12. A new analytical model of high voltage silicon on insulator (SOI) thin film devices

    Institute of Scientific and Technical Information of China (English)

    Hu Sheng-Dong; Zhang Bo; Li Zhao-Ji

    2009-01-01

    A new analytical model of high voltage silicon on insulator (SOI) thin film devices is proposed, and a formula of silicon critical electric field is derived as a function of silicon film thickness by solving a 2D Poisson equation from an effective ionization rate, with a threshold energy taken into account for electron multiplying. Unlike a conventional silicon critical electric field that is constant and independent of silicon film thickness, the proposed silicon critical electric field increases sharply with silicon film thickness decreasing especially in the case of thin films, and can come to 141 V/μm at a film thickness of 0.1 μm which is much larger than the normal value of about 30 V/μm. From the proposed formula of silicon critical electric field, the expressions of dielectric layer electric field and vertical breakdown voltage (VB,V) are obtained. Based on the model, an ultra thin film can be used to enhance dielectric layer electric field and so increase vertical breakdown voltage for SOI devices because of its high silicon critical electric field, and with a dielectric layer thickness of 2 μm the vertical breakdown voltages reach 852 and 300V for the silicon film thicknesses of 0.1 and 5μm, respectively. In addition, a relation between dielectric layer thickness and silicon film thickness is obtained, indicating a minimum vertical breakdown voltage that should be avoided when an SOI device is designed. 2D simulated results and some experimental results are in good agreement with analytical results.

  13. An Underappreciated Radiation Hazard from High Voltage Electrodes in Vacuum

    CERN Document Server

    West, Adam; DeMille, David; West, Elizabeth; Panda, Cristian; Doyle, John; Gabrielse, Gerald; Kryskow, Adam; Mitchell, Corinne

    2016-01-01

    The use of high voltage (HV) electrodes in vacuum is commonplace in physics laboratories. In such systems, it has long been known that electron emission from an HV cathode can lead to bremsstrahlung X-rays; indeed, this is the basic principle behind the operation of standard X-ray sources. However, in laboratory setups where X-ray production is not the goal and no electron source is deliberately introduced, field-emitted electrons accelerated by HV can produce X-rays as an unintended hazardous byproduct. Both the level of hazard and the safe operating regimes for HV vacuum electrode systems are not widely appreciated, at least in university laboratories. A reinforced awareness of the radiation hazards associated with vacuum HV setups would be beneficial. We present a case study of a HV vacuum electrode device operated in a university atomic physics laboratory. We describe the characterisation of the observed X-ray radiation, its relation to the observed leakage current in the device, the steps taken to contai...

  14. High-Capacity, High-Voltage Composite Oxide Cathode Materials

    Science.gov (United States)

    Hagh, Nader M.

    2015-01-01

    This SBIR project integrates theoretical and experimental work to enable a new generation of high-capacity, high-voltage cathode materials that will lead to high-performance, robust energy storage systems. At low operating temperatures, commercially available electrode materials for lithium-ion (Li-ion) batteries do not meet energy and power requirements for NASA's planned exploration activities. NEI Corporation, in partnership with the University of California, San Diego, has developed layered composite cathode materials that increase power and energy densities at temperatures as low as 0 degC and considerably reduce the overall volume and weight of battery packs. In Phase I of the project, through innovations in the structure and morphology of composite electrode particles, the partners successfully demonstrated an energy density exceeding 1,000 Wh/kg at 4 V at room temperature. In Phase II, the team enhanced the kinetics of Li-ion transport and electronic conductivity at 0 degC. An important feature of the composite cathode is that it has at least two components that are structurally integrated. The layered material is electrochemically inactive; however, upon structural integration with a spinel material, the layered material can be electrochemically activated and deliver a large amount of energy with stable cycling.

  15. High-voltage pulsed generator for dynamic fragmentation of rocks.

    Science.gov (United States)

    Kovalchuk, B M; Kharlov, A V; Vizir, V A; Kumpyak, V V; Zorin, V B; Kiselev, V N

    2010-10-01

    A portable high-voltage (HV) pulsed generator has been designed for rock fragmentation experiments. The generator can be used also for other technological applications. The installation consists of low voltage block, HV block, coaxial transmission line, fragmentation chamber, and control system block. Low voltage block of the generator, consisting of a primary capacitor bank (300 μF) and a thyristor switch, stores pulse energy and transfers it to the HV block. The primary capacitor bank stores energy of 600 J at the maximum charging voltage of 2 kV. HV block includes HV pulsed step up transformer, HV capacitive storage, and two electrode gas switch. The following technical parameters of the generator were achieved: output voltage up to 300 kV, voltage rise time of ∼50 ns, current amplitude of ∼6 kA with the 40 Ω active load, and ∼20 kA in a rock fragmentation regime (with discharge in a rock-water mixture). Typical operation regime is a burst of 1000 pulses with a frequency of 10 Hz. The operation process can be controlled within a wide range of parameters. The entire installation (generator, transmission line, treatment chamber, and measuring probes) is designed like a continuous Faraday's cage (complete shielding) to exclude external electromagnetic perturbations.

  16. An Underappreciated Radiation Hazard from High Voltage Electrodes in Vacuum.

    Science.gov (United States)

    West, Adam D; Lasner, Zack; DeMille, David; West, Elizabeth P; Panda, Cristian D; Doyle, John M; Gabrielse, Gerald; Kryskow, Adam; Mitchell, Corinne

    2017-01-01

    The use of high voltage (HV) electrodes in vacuum is commonplace in physics laboratories. In such systems, it has long been known that electron emission from an HV cathode can lead to bremsstrahlung x rays; indeed, this is the basic principle behind the operation of standard x-ray sources. However, in laboratory setups where x-ray production is not the goal and no electron source is deliberately introduced, field-emitted electrons accelerated by HV can produce x rays as an unintended hazardous byproduct. Both the level of hazard and the safe operating regimes for HV vacuum electrode systems are not widely appreciated, at least in university laboratories. A reinforced awareness of the radiation hazards associated with vacuum HV setups would be beneficial. The authors present a case study of a HV vacuum electrode device operated in a university atomic physics laboratory. They describe the characterization of the observed x-ray radiation, its relation to the observed leakage current in the device, the steps taken to contain and mitigate the radiation hazard, and suggested safety guidelines.

  17. High Voltage Coaxial Vacuum Gap Breakdown for Pulsed Power Liners

    Science.gov (United States)

    Cordaro, Samuel; Bott-Suzuki, Simon; Caballero Bendixsen, Luis Sebastian

    2015-11-01

    The dynamics of Magnetized Liner Inertial Fusion (MagLIF)1, are presently under detailed study at Sandia National Laboratories. Alongside this, a comprehensive analysis of the influence of the specific liner design geometry in the MagLIF system on liner initiation is underway in the academic community. Recent work at UC San Diego utilizes a high voltage pulsed system (25kV, 150ns) to analyze the vacuum breakdown stage of liner implosion. Such experimental analyses are geared towards determining how the azimuthal symmetry of coaxial gap breakdown affect plasma initiation within the liner. The final aim of the experimental analysis is to assess to what scale symmetry remains important at high (MV) voltages. An analysis of the above will utilize plasma self-emission via optical MCP, current measurements, voltage measurements near the gap, exact location of breakdown via 2D b-dot probe triangulation, as well as measuring the evolution of the B-field along the length of the liner via b-dot array. Results will be discussed along with analytical calculations of breakdown mechanisms

  18. A high-voltage rechargeable magnesium-sodium hybrid battery

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yifei; An, Qinyou; Cheng, Yingwen; Liang, Yanliang; Ren, Yang; Sun, Cheng-Jun; Dong, Hui; Tang, Zhongjia; Li, Guosheng; Yao, Yan

    2017-04-01

    Growing global demand of safe and low-cost energy storage technology triggers strong interests in novel battery concepts beyond state-of-art Li-ion batteries. Here we report a high-voltage rechargeable Mg–Na hybrid battery featuring dendrite-free deposition of Mg anode and Na-intercalation cathode as a low-cost and safe alternative to Li-ion batteries for large-scale energy storage. A prototype device using a Na3V2(PO4)3 cathode, a Mg anode, and a Mg–Na dual salt electrolyte exhibits the highest voltage (2.60 V vs. Mg) and best rate performance (86% capacity retention at 10C rate) among reported hybrid batteries. Synchrotron radiation-based X-ray absorption near edge structure (XANES), atomic-pair distribution function (PDF), and high-resolution X-ray diffraction (HRXRD) studies reveal the chemical environment and structural change of Na3V2(PO4)3 cathode during the Na ion insertion/deinsertion process. XANES study shows a clear reversible shift of vanadium K-edge and HRXRD and PDF studies reveal a reversible two-phase transformation and V–O bond length change during cycling. The energy density of the hybrid cell could be further improved by developing electrolytes with a higher salt concentration and wider electrochemical window. This work represents a significant step forward for practical safe and low-cost hybrid batteries.

  19. Experimental Study of Electromagnetic Environment in the Vicinity of High Voltage Lines

    Directory of Open Access Journals (Sweden)

    Wafa Tourab

    2011-01-01

    Full Text Available Problem statement: Several studies have investigated the impact of electromagnetic field generated by high voltage power lines on environment. The evaluation of electric and magnetic field quantities are of paramount interest in the characterization of electromagnetic environment of the proposed line. The purpose of this study was to analyze the behavior of electromagnetic fields generated by power lines in an area of strong population. Approach: The method applied in this study was gradual; examined the effects of different couplings between the different neighboring lines on behavior of electric and magnetic fields. Later, these lines will be used as a source of disturbance applied to the auditory implants EMC. Results: The implications of experimental results were also compared and discussed with new standard. Conclusion: The maximum intensities of electric and magnetic fields measured for the circuit of three lines close to each other, within the El-HADJAR substation were significantly lower than the ICNIRP reference levels for occupational and no occupational exposures.

  20. Novel high-voltage power lateral MOSFET with adaptive buried electrodes

    Institute of Scientific and Technical Information of China (English)

    Zhang Wen-Tong; Wu Li-Juan; Qiao Ming; Luo Xiao-Rong; Zhang Bo; Li Zhao-Ji

    2012-01-01

    A new high-voltage and low-specific on-resistance (Ron,sp) adaptive buried electrode (ABE) silicon-on-insulator (SOI) power lateral MOSFET and its analytical model of the electric fields are proposed.The MOSFET features are that the electrodes are in the buried oxide (BOX) layer,the negative drain voltage Vd is divided into many partial voltages and the output to the electrodes is in the buried oxide layer and the potentials on the electrodes change linearly from the drain to the source.Because the interface silicon layer potentials are lower than the neighboring electrode potentials,the electronic potential wells are formed above the electrode regions,and the hole poteutial wells are formed in the spacing of two neighbouring electrode regions.The interface hole concentration is much higher than the electron concentration through designing the buried layer electrode potentials.Based on the interface charge enhanced dielectric layer field theory,the electric field strength in the buried layer is enhanced.The vertical electric field EI and the breakdown voltage (BV) of ABE SOI are 545 V/μm and -587 V in the 50 μm long drift region and the 1 tm thick dielectric layer,and a low Ron,sp is obtained.Furthermore,the structure also alleviates the self-heating effect (SHE).The analytical model matches the simulation results.

  1. JV Task 126 - Mercury Control Technologies for Electric Utilities Burning Bituminous Coal

    Energy Technology Data Exchange (ETDEWEB)

    Jason Laumb; John Kay; Michael Jones; Brandon Pavlish; Nicholas Lentz; Donald McCollor; Kevin Galbreath

    2009-03-29

    The EERC developed an applied research consortium project to test cost-effective mercury (Hg) control technologies for utilities burning bituminous coals. The project goal was to test innovative Hg control technologies that have the potential to reduce Hg emissions from bituminous coal-fired power plants by {ge}90% at costs of one-half to three-quarters of current estimates for activated carbon injection (ACI). Hg control technology evaluations were performed using the EERC's combustion test facility (CTF). The CTF was fired on pulverized bituminous coals at 550,000 Btu/hr (580 MJ/hr). The CTF was configured with the following air pollution control devices (APCDs): selective catalytic reduction (SCR) unit, electrostatic precipitator (ESP), and wet flue gas desulfurization system (WFDS). The Hg control technologies investigated as part of this project included ACI (three Norit Americas, Inc., and eleven Envergex sorbents), elemental mercury (Hg{sup 0}) oxidation catalysts (i.e., the noble metals in Hitachi Zosen, Cormetech, and Hitachi SCR catalysts), sorbent enhancement additives (SEAs) (a proprietary EERC additive, trona, and limestone), and blending with a Powder River Basin (PRB) subbituminous coal. These Hg control technologies were evaluated separately, and many were also tested in combination.

  2. Survey of high voltage electron microscopy worldwide in 1998.

    Energy Technology Data Exchange (ETDEWEB)

    Allen, C. W.

    1998-03-05

    High voltage TEMs were introduced commercially thirty years ago, with the installations of 500 kV Hitachi instruments at the Universities of Nagoya and Tokyo. Since that time 53 commercial instruments, having maximum accelerating potentials of 0.5-3.5 MV, will have been delivered by the end of 1998. Table 1 summarizes the sites and some information regarding those HVEMS which are available in 1998. This corrects, updates and expands an earlier report of this sort [2]. There have been three commercial HVEM manufacturers: AEI (UK), Hitachi and JEOL (Japan). The proportion of the total number of HVEMS produced by each manufacturer is similar to that reflected in Table 1: AEI and Kratos/AEI (12), Hitachi (20) and JEOL (21). The term Kratos/AEI refers to instruments delivered after the takeover of AEI by Grates in the late 1970's. In Table 1 only maximum accelerating potentials are listed, which is generally also the design value for which the resolution for imaging was optimized. It is important to realize that in many applications, especially those studying irradiation effects, much lower voltages may be employed somewhat routinely to minimize atom displacements by the incident electron beam during analysis. These minimum values range from 100 kV for the AEI and Kratos/AEI instruments to typically 400 kV for the current generation of atomic resolution instruments, the latter being well above the thresholds for displacement in light elements such as Al and Si and for displacement of anions in many ceramic materials such as the high Tc superconductors, for example. An additional potential problem is electron-induced sputtering and differential sputtering (unequal sputtering rates in multicomponent materials), especially when accurate elemental microanalysis is being attempted. These same issues may arise for intermediate voltage TEMs as well, of course.

  3. High voltage, low inductance hydrogen thyratron study program

    Science.gov (United States)

    Caristi, R. F.; Turnquist, D.

    1981-01-01

    The second phase of a multi-phase program of research and development to gain the information necessary to fabricate a high voltage, low inductance hydrogen thyratron switch has now been completed. The thyratron is to be capable of switching tens of kiloamperes within tens of nanoseconds at voltage levels as high as 250 kV. To achieve low inductance, the thyratron is operated within a close-fitting coaxial current return. Both the tube and the return are made physically short, and the tube is designed such that the discharge is constrained to flow principally at the outer reaches of the device. A technique has been developed for modelling various types of box grids and then using computer-generated field plots to aid in the specifics of grid design. This model has been used to generate a comprehensive set of theoretical relations that are useful to determine the anode dissipation to be expected. Experimental results are described and discussed. Included are the ceramic test results, holdoff vs. time on charge and gas pressure, stage voltage addition, operation at high pulse repetition rates, current rise time as a function of gas pressure, and the triggering characteristics of multi-stage, box-grid tubes. Finally, the design of an intermediate experimental tube is discussed at length. This tube is expected to have an inductance less than 50 nH and to operate at 150 kV. Its design is based on both the theoretical and experimental results obtained during this phase of the research program. The overall conclusion is that a hydrogen thyratron capable of achieving the program's objectives is a feasible proposition.

  4. DC buffering and floating current for a high voltage IMB application

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, J. L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-08-01

    An interface technique for the latest generation of the Impedance Measurement Box (IMB) has been conceived to enable measurement of impedance spectra for battery modules up to 300V. A 300V capable or higher IMB is an enabling technology for in-situ diagnostics within electric vehicle charging stations or battery back-ups within power distribution sub-stations. It is possible that the existing IMB can be adapted via a 300V interface module to a test battery with voltage significantly greater than 50V. Recently a new concept was conceived for the calibration, algorithm and electronics of the IMB. That algorithm and calibration for that concept have been physically validated. The principal feature of the new electronics is the floating current source excitation of the battery under test. The single ended current excitation of the battery under test, used in the 50V IMB, requires that the negative terminal of the test battery must be the analog ground for the IMB. The new floating current technique allows the test battery to be fully high impedance isolated for a measurement. That isolation will improve IMB noise immunity and enable interrogation of cells internal to a battery module. All these techniques still use the same rapid concept for impedance measurement with the IMB. The purpose of this disclosure is to provide an overview of the analytical validation for three concepts to interface the floating current excitation to a high voltage battery. Recursive simulation models were used in different test scenarios to validate the various new concepts. The analysis will show that it is possible to interface the floating signal current to obtain an impedance measurement on a high voltage test battery. Additionally, the analysis will investigate stress seen by electronics while testing a 300V battery.

  5. Hardware and software system for monitoring oil pump operation in power high-voltage transformers

    Directory of Open Access Journals (Sweden)

    Михайло Дмитрович Дяченко

    2017-07-01

    Full Text Available The article considers the basic prerequisites for the creation of an automated monitoring system for oil pumps of high-voltage transformers. This is due to the fact that the long operation of oil pumps results in deterioration and destruction of bearings, rubbing of the rotor, breakage and damage to the impeller, leakage, etc., which inevitably causes a significant decrease in the insulating properties of the transformer oil and leads to expenditures for its further recovery. False triggerings of gas protection sometimes occur. Continuous operation of the electric motor also requires additional equipment to protect the motor itself from various emergency situations, such as a short in the stator winding, a housing breakdown, an incomplete phase mode, etc. The use of stationary systems provides: diagnosing defects at an early stage of their development, increasing the reliability and longevity of the equipment components, increasing the overhaul period, decreasing the number of emergency stops, and adjusting the schedule of preventative maintenance. The basic principles of identification of the damaged part of the oil pump are given, the hardware and algorithmic solutions are considered in the work. The full-scale tests of the model sample on the power transformer of the high-voltage substation confirmed the assumption of the possibility of detecting the damaged unit separating it from the rest connected in one mechanical structure. A detailed analysis of the operation of each of the units is carried out by means of the general substation switchboard and displayed as graphs, diagrams and text messages. When the limit values of vibration are reached, faults in the operation of the unit are detected, the overlimit current values, a warning alarm is activated, and the command to disconnect the damaged unit is issued. The optimal solution for the organization of the information collection system using the principle of sensor networks, but combined

  6. Development of high-voltage pulse generator with variable amplitude and duration

    Science.gov (United States)

    Upadhyay, J.; Sharma, M. L.; Ahuja, Aakash B.; Navathe, C. P.

    2014-06-01

    A high voltage pulse generator with variable amplitude (100-3000 V) and duration (100-2000 μs) has been designed and developed. The variable duration pulse has been generated by adopting a simple and novel technique of varying the turn off delay time of a high voltage Metal Oxide Semiconductor Field Effect Transistor (MOSFET) based switch by varying external gate resistance. The pulse amplitude is made variable by adjusting biasing supply of the high voltage switch. The high voltage switch has been developed using a MOSFET based stack of 3 kV rating with switching time of 7 ns.

  7. Installation and cosmic ray test of the high voltage system of the BESⅢdrift chamber

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    After examination of the designed high voltage power supply system of the BESⅢ drift chamber in the beam test of the full length prototype of drift chamber,a full system covering all the channels of high voltage was installed.The system's training and the high voltage value adjustment were carried out in the cosmic ray test of the BESⅢ drift chamber.The cosmic ray test for the full system and its final installation on the BESⅢ drift chamber were reported.The full system of high voltage power supply works stably and reliably.

  8. Method and system for a gas tube-based current source high voltage direct current transmission system

    Energy Technology Data Exchange (ETDEWEB)

    She, Xu; Chokhawala, Rahul Shantilal; Bray, James William; Sommerer, Timothy John; Zhou, Rui; Zhang, Di

    2017-08-29

    A high-voltage direct-current (HVDC) transmission system includes an alternating current (AC) electrical source and a power converter channel that includes an AC-DC converter electrically coupled to the electrical source and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and the DC-AC inverter each include a plurality of legs that includes at least one switching device. The power converter channel further includes a commutating circuit communicatively coupled to one or more switching devices. The commutating circuit is configured to "switch on" one of the switching devices during a first portion of a cycle of the H-bridge switching circuits and "switch off" the switching device during a second portion of the cycle of the first and second H-bridge switching circuits.

  9. Correction, Calculation and Experimental Adjustment of Burner, Destined for Burning Methane in Electric Field

    OpenAIRE

    Pavel KLAUS; Tomčík, Petr; Kulhánek, Jiří

    2011-01-01

    In this paper was solved modification of combustion burner for experimental exam of methane combustion in the electric field with high intensity voltage. The burner was originally designed for the combustion stack gas. The burner must have been necessary adjusted, because the mixture of stack gas and air was replaced by mixture of methane and oxygen. The fundamental requirement is to adjust the height of the flame that may reach a maximum of height 100 mm. This height was re-quired because th...

  10. Ionizing potential waves and high-voltage breakdown streamers.

    Science.gov (United States)

    Albright, N. W.; Tidman, D. A.

    1972-01-01

    The structure of ionizing potential waves driven by a strong electric field in a dense gas is discussed. Negative breakdown waves are found to propagate with a velocity proportional to the electric field normal to the wavefront. This causes a curved ionizing potential wavefront to focus down into a filamentary structure, and may provide the reason why breakdown in dense gases propagates in the form of a narrow leader streamer instead of a broad wavefront.

  11. The thermal regime around buried submarine high-voltage cables

    Science.gov (United States)

    Emeana, C. J.; Hughes, T. J.; Dix, J. K.; Gernon, T. M.; Henstock, T. J.; Thompson, C. E. L.; Pilgrim, J. A.

    2016-08-01

    The expansion of offshore renewable energy infrastructure and the need for trans-continental shelf power transmission require the use of submarine high-voltage (HV) cables. These cables have maximum operating surface temperatures of up to 70 °C and are typically buried 1-2 m beneath the seabed, within the wide range of substrates found on the continental shelf. However, the heat flow pattern and potential effects on the sedimentary environments around such anomalously high heat sources in the near-surface sediments are poorly understood. We present temperature measurements from a 2-D laboratory experiment representing a buried submarine HV cable, and identify the thermal regimes generated within typical unconsolidated shelf sediments—coarse silt, fine sand and very coarse sand. We used a large (2 × 2.5 m2) tank filled with water-saturated spherical glass beads (ballotini) and instrumented with a buried heat source and 120 thermocouples to measure the time-dependent 2-D temperature distributions. The observed and corresponding Finite Element Method simulations of the steady state heat flow regimes and normalized radial temperature distributions were assessed. Our results show that the heat transfer and thus temperature fields generated from submarine HV cables buried within a range of sediments are highly variable. Coarse silts are shown to be purely conductive, producing temperature increases of >10 °C up to 40 cm from the source of 60 °C above ambient; fine sands demonstrate a transition from conductive to convective heat transfer between cf. 20 and 36 °C above ambient, with >10 °C heat increases occurring over a metre from the source of 55 °C above ambient; and very coarse sands exhibit dominantly convective heat transfer even at very low (cf. 7 °C) operating temperatures and reaching temperatures of up to 18 °C above ambient at a metre from the source at surface temperatures of only 18 °C. These findings are important for the surrounding near

  12. Low-profile high-voltage compact gas switch

    Energy Technology Data Exchange (ETDEWEB)

    Goerz, D.A.; Wilson, M.J.; Speer, R.D.

    1997-06-30

    This paper discusses the development and testing of a low-profile, high-voltage, spark-gap switch designed to be closely coupled with other components into an integrated high-energy pulsed-power source. The switch is designed to operate at 100 kV using SF6 gas pressurized to less than 0.7 MPa. The volume of the switch cavity region is less than 1.5 cm3, and the field stress along the gas-dielectric interface is as high as 130 kV/cm. The dielectric switch body has a low profile that is only I -cm tall at its greatest extent and nominally 2-mm thick over most of its area. This design achieves a very low inductance of less than 5 nH, but results in field stresses exceeding 500 kV/cm in the dielectric material. Field modeling was done to determine the appropriate shape for the highly stressed insulator and electrodes, and special manufacturing techniques were employed to mitigate the usual mechanisms that induce breakdown and failure in solid dielectrics. Static breakdown tests verified that the switch operates satisfactorily at 100 kV levels. The unit has been characterized with different shaped electrodes having nominal gap spacings of 2.0, 2.5, and 3.0 mm. The relationship between self-break voltage and operating pressure agrees well with published data on gas properties, accounting for the field enhancements of the electrode shapes being used. Capacitor discharge tests in a low inductance test fixture exhibited peak currents up to 25 kA with characteristic frequencies of the ringdown circuit ranging from 10 to 20 MHz. The ringdown waveforms and scaling of measured parameters agree well with circuit modeling of the switch and test fixture. Repetitive operation has been demonstrated at moderate rep-rates up to 15 Hz, limited by the power supply being used. Preliminary tests to evaluate lifetime of the compact switch assembly have been encouraging. In one case, after more than 7,000 high-current ringdown tests with approximately 30 C of total charge transferred, the

  13. High-Voltage-Input Level Translator Using Standard CMOS

    Science.gov (United States)

    Yager, Jeremy A.; Mojarradi, Mohammad M.; Vo, Tuan A.; Blalock, Benjamin J.

    2011-01-01

    proposed integrated circuit would translate (1) a pair of input signals having a low differential potential and a possibly high common-mode potential into (2) a pair of output signals having the same low differential potential and a low common-mode potential. As used here, "low" and "high" refer to potentials that are, respectively, below or above the nominal supply potential (3.3 V) at which standard complementary metal oxide/semiconductor (CMOS) integrated circuits are designed to operate. The input common-mode potential could lie between 0 and 10 V; the output common-mode potential would be 2 V. This translation would make it possible to process the pair of signals by use of standard 3.3-V CMOS analog and/or mixed-signal (analog and digital) circuitry on the same integrated-circuit chip. A schematic of the circuit is shown in the figure. Standard 3.3-V CMOS circuitry cannot withstand input potentials greater than about 4 V. However, there are many applications that involve low-differential-potential, high-common-mode-potential input signal pairs and in which standard 3.3-V CMOS circuitry, which is relatively inexpensive, would be the most appropriate circuitry for performing other functions on the integrated-circuit chip that handles the high-potential input signals. Thus, there is a need to combine high-voltage input circuitry with standard low-voltage CMOS circuitry on the same integrated-circuit chip. The proposed circuit would satisfy this need. In the proposed circuit, the input signals would be coupled into both a level-shifting pair and a common-mode-sensing pair of CMOS transistors. The output of the level-shifting pair would be fed as input to a differential pair of transistors. The resulting differential current output would pass through six standoff transistors to be mirrored into an output branch by four heterojunction bipolar transistors. The mirrored differential current would be converted back to potential by a pair of diode-connected transistors

  14. Hybrid electric vehicle power management system

    Energy Technology Data Exchange (ETDEWEB)

    Bissontz, Jay E.

    2015-08-25

    Level voltage levels/states of charge are maintained among a plurality of high voltage DC electrical storage devices/traction battery packs that are arrayed in series to support operation of a hybrid electric vehicle drive train. Each high voltage DC electrical storage device supports a high voltage power bus, to which at least one controllable load is connected, and at least a first lower voltage level electrical distribution system. The rate of power transfer from the high voltage DC electrical storage devices to the at least first lower voltage electrical distribution system is controlled by DC-DC converters.

  15. EFFECTS OF ELECTROMAGNETIC FIELDS ON HEMATOPOISIS SYSTEM: STUDY ON WORKERS AT HIGH- VOLTAGE SUBSTATIONS

    Directory of Open Access Journals (Sweden)

    H.A YOUSEFI

    2001-06-01

    Full Text Available Introduction: The goal of this study was to evaluate the relationship between occupational exposure to extremely low frequency (ELF electromagnetic fields and risk of Hematological changes among workers at High- voltage substations. This is a case - control study. In the present study 79 worker exposed to electromagetic fields (EMFs were compared to 50 control subjects who were not occupationaly exposed to EMFs. Methods: To measurement the levels of exposure to Lf electric and magnetic fields the strength of electric and magnetic field was determined by Dosimetric method. Worker"s blood samples were collected and analyzed for identification of leukemia and other abnormalities. Questionnaire and physical examination were used to study the effects of ELF fields on worker"s health. Measurements showed a high strength of ELF fields at the work places i.e. Results: Mean value of RBC and Hematocrit decreased significantly among exposed workers compared to controls (P < 0.05, but MCV, MCH and MCHC increased. The value of Neutrophiles increased but Lymphocytes decreased significantly among workers considering their workhistory (P < 0.05. Discussion: Moreover, tow leukemics (ALL, AML and ten hypocromic anemias were found. In conclusion study groups are similar in personal characteristics, the difference in RBC, MCV, MCH has to attributed to ELF fields.

  16. Degradation of High Voltage Polymeric Insulators in Arid Desert's Simulated Environmental Conditions

    Directory of Open Access Journals (Sweden)

    Yasin Khan

    2009-01-01

    Full Text Available Problem statement: High Voltage (HV polymeric insulators are replacing ceramic insulator commonly used for HV outdoor networks due to their ease of handling, reliability and cost. However, their long term performance and reliability are major concerns to power utilities. Approach: To investigate their performance in arid desert's conditions, two types of HV composite insulators were aged as per International Electrochemical Commission (IEC standard-61109. Additional test samples were subjected to accelerated aging conditions simulating the actual Ultraviolet (UV radiation intensity and temperature in the inland desert. Results: This study described the experimental results of the effects of thermo electric stress and UV radiations on the polymeric insulators aged under two conditions i.e., as per IEC standard and modified IEC standard that simulates the inland arid desert. The tests results after the artificial accelerated aging indicated that the dielectric response of thermoplastic insulators under the tested thermo-electric cum UV-irradiations outperforms Silicone rubber insulators.Conclusion: From the obtained results it will be easy to assess the performance and suitability of composite insulators for their applications in arid desert environments.

  17. High voltage bulk GaN-based photoconductive switches for pulsed power applications

    Science.gov (United States)

    Leach, J. H.; Metzger, R.; Preble, E. A.; Evans, K. R.

    2013-03-01

    Switches are at the heart of all pulsed power and directed energy systems, which find utility in a number of applications. At present, those applications requiring the highest power levels tend to employ spark-gap switches, but these suffer from relatively high delay-times (~10-8 sec), significant jitter (variation in delay time), and large size. That said, optically-triggered GaN-based photoconductive semiconductor switches (PCSS) offer a suitably small form factor and are a cost-effective, versatile solution in which delay times and jitter can be extremely short. Furthermore, the optical control of the switch means that they are electrically isolated from the environment and from any other system circuitry, making them immune from electrical noise, eliminating the potential for inadvertent switch triggering. Our recent work shows great promise to extend high-voltage GaN-based extrinsic PCSS state-of-the-art performance in terms of subnanosecond response times, low on-resistance, high current carrying capacity and high blocking voltages. We discuss our recent results in this work.

  18. Mixed Electronic and Ionic Conductor-Coated Cathode Material for High-Voltage Lithium Ion Battery.

    Science.gov (United States)

    Shim, Jae-Hyun; Han, Jung-Min; Lee, Joon-Hyung; Lee, Sanghun

    2016-05-18

    A lithium ionic conductor, Li1.3Al0.3Ti1.7(PO4)3 (LATP), is introduced as a coating material on the surface of Mg-doped LiCoO2 to improve electrochemical performances for high-voltage (4.5 V) lithium ion batteries. Structure, morphology, elemental distribution, and electrical properties of the materials are thoroughly characterized by SEM, TEM, EELS, EDS, and C-AFM. The coating layer is electrically conductive with the aid of Mg ions which are used as a dopant for the active materials; therefore, this mixed electronic ionic conductor strongly enhances the electrochemical performances of initial capacity, cycling property, and rate capability. The LATP coating layer also demonstrates very promising applicability for 4.4 V prismatic full cells with graphite anode, which correspond to the 4.5 V half-cells with lithium anode. The 2900 mA h full cells show 85% of capacity retention after 500 cycles and more than 60% after 700 cycles.

  19. A novel high-voltage device structure with an N+ ring in substrate and the breakdown voltage model

    Institute of Scientific and Technical Information of China (English)

    Li Qi; Zhu Jinluan; Wang Weidong; Yue Hongwei; Jin Liangnian

    2011-01-01

    A novel high-voltage device structure with a floating heavily doped N+ ring embedded in the substrate is reported,which is called FR LDMOS.When the N+ ring is introduced in the device substrate,the electric field peak of the main junction is reduced due to the transfer of the voltage from the main junction to the N+ ring junction,and the vertical breakdown characteristic is improved significantly.Based on the Poisson equation of cylindrical coordinates,a breakdown voltage model is developed.The numerical results indicate that the breakdown voltage of the proposed device is increased by 56% in comparison to conventional LDMOS.

  20. LIFE MANAGEMENT OF ASSET FROM HIGH VOLTAGE SUBSTATION

    Directory of Open Access Journals (Sweden)

    Sorina COSTINAŞ

    2010-11-01

    Full Text Available Companies have to reinvent continuously their business model. Maintenance can play a key role in the long-term profitability of a company. In Romania, especially since the liberalization of the energy market, the electrical companies are forced to identify and coordinate a lot of processes and to promote competitivity. It is necessary to work safety and be environmentally responsible in order to achieve electrical substations obiectives. In this paper will be presented maintenance strategy (replacement, upgrade or repair and informational aspects of decisional process (technical, financial, social politic, legal and risk aspects. Proposed methodology regarding the maintenance of electrical substation will be focused in how to improve the decisions for improving asset maintenance performance through ISO 9001/14001.

  1. A consistent approach to estimate the breakdown voltage of high voltage electrodes under positive switching impulses

    Science.gov (United States)

    Arevalo, L.; Wu, D.; Jacobson, B.

    2013-08-01

    The main propose of this paper is to present a physical model of long air gap electrical discharges under positive switching impulses. The development and progression of discharges in long air gaps are attributable to two intertwined physical phenomena, namely, the leader channel and the streamer zone. Experimental studies have been used to develop empirical and physical models capable to represent the streamer zone and the leader channel. The empirical ones have led to improvements in the electrical design of high voltage apparatus and insulation distances, but they cannot take into account factors associated with fundamental physics and/or the behavior of materials. The physical models have been used to describe and understand the discharge phenomena of laboratory and lightning discharges. However, because of the complex simulations necessary to reproduce real cases, they are not in widespread use in the engineering of practical applications. Hence, the aim of the work presented here is to develop a model based on physics of the discharge capable to validate and complement the existing engineering models. The model presented here proposes a new geometrical approximation for the representation of the streamer and the calculation of the accumulated electrical charge. The model considers a variable streamer region that changes with the temporal and spatial variations of the electric field. The leader channel is modeled using the non local thermo-equilibrium equations. Furthermore, statistical delays before the inception of the first corona, and random distributions to represent the tortuous nature of the path taken by the leader channel were included based on the behavior observed in experimental tests, with the intention of ensuring the discharge behaved in a realistic manner. For comparison purposes, two different gap configurations were simulated. A reasonable agreement was found between the physical model and the experimental test results.

  2. Numerical modeling of high-voltage circuit breaker arcs and their interraction with the power system

    Science.gov (United States)

    Orama, Lionel R.

    In this work the interaction between series connected gas and vacuum circuit breaker arcs has been studied. The breakdown phenomena in vacuum interrupters during the post arc current period have been of special interest. Numerical models of gas and vacuum arcs were developed in the form of black box models. Especially, the vacuum post arc model was implemented by combining the existing transition model with an ion density function and expressions for the breakdown mechanisms. The test series studied reflect that for electric fields on the order of 10sp7V/m over the anode, the breakdown of the vacuum gap can result from a combination of both thermal and electrical stresses. For a particular vacuum device, the vacuum model helps to find the interruption limits of the electric field and power density over the anode. The series connection of gas and vacuum interrupters always performs better than the single gas device. Moreover, to take advantage of the good characteristics of both devices, the time between the current zero crossing in each interrupter can be changed. This current zero synchronization is controlled by changing the capacitance in parallel to the gas device. This gas/vacuum interrupter is suitable for interruption of very stressful short circuits in which the product of the dI/dt before current zero and the dV/dt after current zero is very high. Also, a single SF6 interrupter can be replaced by an air circuit breaker of the same voltage rating in series with a vacuum device without compromising the good performance of the SF6 device. Conceptually, a series connected vacuum device can be used for high voltage applications with equal distribution of electrical stresses between the individual interrupters. The equalization can be made by a sequential opening of the individual contact pairs, beginning with the interruptors that are closer to ground potential. This could eliminate the use of grading capacitors.

  3. 30 CFR 75.802 - Protection of high-voltage circuits extending underground.

    Science.gov (United States)

    2010-07-01

    ... underground. 75.802 Section 75.802 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.802 Protection of high-voltage circuits extending underground. (a) Except as...

  4. 76 FR 70721 - Voltage Coordination on High Voltage Grids; Notice of Staff Workshop

    Science.gov (United States)

    2011-11-15

    ... Energy Regulatory Commission Voltage Coordination on High Voltage Grids; Notice of Staff Workshop Take notice that the Federal Energy Regulatory Commission will hold a Workshop on Voltage Coordination on High Voltage Grids on Thursday, December 1, 2011 from 9 a.m. to 4:30 p.m. This staff-led workshop will be...

  5. 30 CFR 57.12071 - Movement or operation of equipment near high-voltage powerlines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Movement or operation of equipment near high-voltage powerlines. 57.12071 Section 57.12071 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION...-voltage powerlines. When equipment must be moved or operated near energized high-voltage powerlines...

  6. 30 CFR 77.807-2 - Booms and masts; minimum distance from high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ...-voltage lines. 77.807-2 Section 77.807-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.807-2 Booms and masts; minimum distance from high-voltage lines. The booms and masts of equipment operated on the surface of...

  7. Debugging on High-voltage Power Supply,Focusing Power Supply and Magnetic Field Power Supply

    Institute of Scientific and Technical Information of China (English)

    TU; Rui

    2015-01-01

    High-voltage power supply,focusing power supply and magnetic field power supply are the main parts of the power supply system of the EMIS(Electro-Magnetic Isotope Separator)supplying the ion source.In 2015,a high-voltage power supply,power supply for focusing and

  8. High-voltage, short-risetime pulse generator based on a ferrite pulse sharpener

    Energy Technology Data Exchange (ETDEWEB)

    Seddon, N.; Thornton, E.

    1988-11-01

    A high-voltage, short-risetime pulse generator is described. The generator consists of a Marx bank, which produces an initial high-voltage pulse, and a ferrite pulse sharpener that reduces the risetime of the pulse. The generator delivers 70-kV, 350-ps risetime pulses into a 50-..cap omega.. load.

  9. [Design of a high-voltage insulation testing system of X-ray high frequency generators].

    Science.gov (United States)

    Huang, Yong; Mo, Guo-Ming; Wang, Yan; Wang, Hong-Zhi; Yu, Jie-Ying; Dai, Shu-Guang

    2007-09-01

    In this paper, we analyze the transformer of X-ray high-voltage high-frequency generators and, have designed and implemented a high-voltage insulation testing system for its oil tank using full-bridge series resonant soft switching PFM DC-DC converter.

  10. First high-voltage measurements using Ca{sup +} ions at the ALIVE experiment

    Energy Technology Data Exchange (ETDEWEB)

    König, K., E-mail: kkoenig@ikp.tu-darmstadt.de [Technische Universität Darmstadt, Institut für Kernphysik (Germany); Geppert, Ch. [Universität Mainz, Institut für Kernchemie (Germany); Krämer, J.; Maaß, B. [Technische Universität Darmstadt, Institut für Kernphysik (Germany); Otten, E. W. [Universität Mainz, Institut für Physik (Germany); Ratajczyk, T.; Nörtershäuser, W. [Technische Universität Darmstadt, Institut für Kernphysik (Germany)

    2017-11-15

    Many physics experiments depend on accurate high-voltage measurements to determine for example the exact retardation potential of an electron spectrometer as in the KATRIN experiment or the acceleration voltage of the ions at ISOL facilities. Until now only precision high-voltage dividers can be used to measure voltages up to 65 kV with an accuracy of 1 ppm. However, these dividers need frequent calibration and cross-checking and the direct traceability is not given. In this article we will describe the status of an experiment which aims to measure high voltages using collinear laser spectroscopy and which has the potential to provide a high-voltage standard and hence, a calibration source for precision high-voltage dividers on the 1 ppm level.

  11. Consideration and research of high voltage insulation strategy for ITER Feeder busbar joint

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xiongyi [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Song, Yuntao, E-mail: songyt@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Zheng, Jinxing; Yu, Xiaowu; Xiao, Weiwu; Gao, Daming; Tao, Yuming; Wang, Chunyu [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Gung, Chen-yu; Clayton, Nicholas [ITER IO, Tokamak Department, Magnet Division, 13067 St. Paul lez Durance (France); Niu, Erwu [China International Nuclear Fusion Energy Program Execution, Beijing 100086 (China); Chen, Yonghua; Mitcell, Neil [ITER IO, Tokamak Department, Magnet Division, 13067 St. Paul lez Durance (France)

    2013-10-15

    Highlights: • Several rounds insulation trials for ITER Feeder joint were carried out in ASIPP. • Wet-winding, VPI were practiced and attempt for the best impregnation strategy. • Improvement of wet-winding technology with vacuum assistance was realized. • To supplement the electrical test, DR technology was explored for insulation quality inspection. -- Abstract: The ITER Feeder busbar joint is an important component which connects different sections of busbar which run from the high temperature superconducting current leads to the magnet terminals. High voltage insulated bus bar sections will be assembled onto the feeder support structure (called the containment duct), and the joints between sections will be made in situ. The high voltage insulation over the joint is the final step to complete the insulation of the whole bus bar system, and its quality is key to achieving the required electrical performance of the system. The final joint has a complex external configuration with an irregular structure in places, which makes it difficult for the application of the insulation. The limited access in the Feeder and the complex joint external structure make the implementation of the joint insulation hard to solve. The Feeder group at ASIPP has carried out significant R and D for the joint insulation, involving research on the selection of materials, the design of the insulation structure, the curing technology and the quality inspection method. After many rounds of manufacturing and testing, the insulation strategy for the Feeder joint will focus on the so-called “wet-winding” technology. Despite the fact that this process has some intrinsic disadvantages, it is more appropriate for the joint structure compared to other methods. The sub-suppliers to ASIPP have chosen this impregnation method for the feeder qualification activities based on guidance from ASIPP. This paper describes the research procedure of the ITER Feeder busbar joint insulation

  12. Design of an Actinide-Burning, Lead or Lead-Bismuth Cooled Reactor that Produces Low-Cost Electricity

    Energy Technology Data Exchange (ETDEWEB)

    Mac Donald, Philip Elsworth; Weaver, Kevan Dean; Davis, Cliff Bybee; MIT folks

    2000-07-01

    The purpose of this Idaho National Engineering and Environmental Laboratory (INEEL) and Massachusetts Institute of Technology (MIT) University Research Consortium (URC) project is to investigate the suitability of lead or lead-bismuth cooled fast reactors for producing low-cost electricity as well as for actinide burning. The goal is to identify and analyze the key technical issues in core neutronics, materials, thermal-hydraulics, fuels, and economics associated with the development of this reactor concept. Work has been accomplished in four major areas of research: core neutronic design, material compatibility, plant engineering, and coolant activation. In the area of core neutronic design, the reactivity vs. burnup and discharge isotopics of both non-fertile and fertile fuels were evaluated. An innovative core for pure actinide burning that uses streaming, fertile-free fuel assemblies was studied in depth. This particular core exhibits excellent reactivity performance upon coolant voiding, even for voids that occur in the core center, and has a transuranic (TRU) destruction rate that is comparable to the proposed accelerator transmutation of waste (ATW) facility. These studies suggest that a core can be designed to achieve a long life while maintaining safety and minimizing waste. In the area of material compatibility studies, an experimental apparatus for the investigation of the flow-assisted dissolution and precipitation (corrosion) of potential fuel cladding and structural materials has been designed and built at the INEEL. The INEEL forced-convection corrosion cell consists of a small heated vessel with a shroud and gas flow system. The corrosion cell is being used to test steel that is commercially available in the United States to temperatures above 650°C. Progress in plant engineering was made for two reactor concepts, one utilizing an indirect cycle with heat exchangers and the other utilizing a direct-contact steam cycle. The evaluation of the

  13. How to manage burns in primary care.

    OpenAIRE

    Waitzman, A. A.; Neligan, P C

    1993-01-01

    Burns are common injuries; more than 200,000 occur in Canada annually. Nearly all burn injuries can be managed on on outpatient basis. Appropriate treatment depends on burn depth, extent, and location. Special types of burns, such as chemical, tar, and electrical injuries, need specific management strategies. Prevention through education is important to reduce the incidence of burns.

  14. On the Anomalous Weight Losses of High Voltage Symmetrical Capacitors

    CERN Document Server

    Porcelli, Elio B

    2015-01-01

    In this work, we analyzed an anomalous effect verified from symmetrical capacitor devices, working in very high electric potentials. The mastery of that effect could mean in the future the possible substitution of propulsion technology based on fuels by single electrical propulsion systems. From experimental measurements, we detected small variations of the device inertia that cannot be associated with known interactions, so that the raised force apparently has not been completely elucidated by current theories. We measured such variations within an accurate range and we proposed that the experimental results can be explained by relations like Clausius-Mossotti one, in order to quantify the dipole forces that appear in the devices. The values of the weight losses in the capacitors were calculated by means of the theoretical proposal and indicated good agreement with our experimental measurements for 7kV and with many other experimental works.

  15. A new high voltage SOILDMOS with triple RESURF structure

    Institute of Scientific and Technical Information of China (English)

    Hu Xiarong; Zhang Bo; Luo Xiaorong; Yao Guoliang; Chen Xi; Li Zhaoji

    2011-01-01

    A novel triple RESURF (T-resurf) SOILDMOS structure is proposed.This structure has a P-type buried layer.Firstly,the depletion layer can extend on both sides of the P-buried layer,serving as a triple RESURF and leading to a high drift doping and a low on-resistance.Secondly,at a high doping concentration of the drift region,the P-layer can reduce high bulk electric field in the drift region and enhance the vertical electric field at the drain side,which results in uniform bulk electric field distributions and an enhanced BV.The proposed structure is used in SOI devices for the first time.The T-resurf SOILDMOS with BV =315 V is obtained by simulation on a 6 μm-thick SOI layer over a 2 μm-thick buried oxide layer,and its Rsp is reduced from 16.5 to 13.8 mΩ.cm2 in comparison with the double RESURF (D-resurf) SOILDMOS.When the thickness of the SOI layer increases,T-resurf SOILDMOS displays a more obvious effect on the enhancement of BV2/Ron.It reduces Rsp by 25% in 400 V SOILDMOS and by 38% in 550 V SOI LDMOS compared with the D-resurf structure.

  16. Economics of pediatric burns.

    Science.gov (United States)

    Bass, Michael J; Phillips, Linda G

    2008-07-01

    Sustaining a burn injury sets in motion a cycle of pain, disfigurement, and a search for survival. In pediatric burns, the injury extends to the parents where fear, ignorance, and helplessness forever change their lives. Pediatric burn injuries are caused by fire, hot liquids, clothing irons, hair curlers, caustic substances like drain cleaner, the grounding of an electrical source, and exposure to radiation. Efficiency in the delivery of pediatric burn care is critical. Maximizing resource utilization means continual self-evaluation and economic analysis of therapeutic modalities. Griffiths et al found that most childhood burns are due to scalds, which can be treated for $1061 per percent burn. Paddock et al reduced the cost of treating superficial pediatric burns and reduced the length of stay in hospital using silver-impregnated gauze over traditional methods. Barrett et al found improved cosmesis of skin grafts using cultured epithelial autografts but at a substantially increased cost. Corpron et al showed that pediatric burn units that treat burns >10% total body surface area and operative treatment of pediatric burns regardless of size generate positive revenue. There is a paucity of evidentiary pediatric burn economic data. More research is needed to address areas of pediatric burn care inefficiency. Improving knowledge of cost in all health care endeavors will create competition and drive down expenditures.

  17. Investigating the burning characteristics of electric cables used in the nuclear power plant by way of 3-D transient FDS code

    Energy Technology Data Exchange (ETDEWEB)

    Ferng, Y.M., E-mail: ymferng@ess.nthu.edu.t [Department of Engineering and System Science, Institute of Nuclear Engineering and Science, National Tsing Hua University, 101, Sec. 2. Kuang-Fu Rd., Hsinchu 30013, Taiwan (China); Liu, C.H. [Department of Engineering and System Science, Institute of Nuclear Engineering and Science, National Tsing Hua University, 101, Sec. 2. Kuang-Fu Rd., Hsinchu 30013, Taiwan (China)

    2011-01-15

    Burning characteristics of electrical cables are one of the key parameters for the fire hazard assessment of nuclear power plants (NPPs) since the cables are the essential sources of fire in the plants. A three-dimensional (3-D) transient computational fluid dynamics (CFD) code{sub F}DS is adopted in this paper to simulate these characteristics related to the cable burning. Being one of the NRC licensing fire codes, the FDS includes the thermal-hydraulic equations, the turbulence model and the chemical combustion model, etc. In order to assess the CFD fire models used in this code, a burning test using the control cable with the outer jacket of polyvinylchloride (PVC) and the inner insulation of cross-linked polyethylene (XLPE) is conducted. The measured parameters associated with the burning characteristics include the heat release rate (HRR), O{sub 2} depletion, and CO and CO{sub 2} production, etc. Except the amount of O{sub 2} consumption, the predicted transient behaviors of other parameters can reproduce the measured data. Based on the chemical combustion model in the FDS code, this discrepancy may be essentially resulted from the default value of hydrogen fraction (H{sub frac}) contained in the soot since the soot yield for the burning of PVC material is high enough that the uncertainty in the H{sub frac} value has a prominent effect on the amount of O{sub 2} consumption. This explanation can be confirmed by a benchmark calculation for simulating a burning test with the polymethylmethacrylate (PMMA) fuel of low-soot yield. The present simulation works can provide the useful information for the plant staff or the researcher as they would perform the fire hazard analysis in the NPPs using the FDS code.

  18. Jasmonic acid accumulation and systemic photosynthetic and electrical changes in locally burned wild type tomato, ABA-deficient sitiens mutants and sitiens pre-treated by ABA.

    Science.gov (United States)

    Hlavinka, Jan; Nožková-Hlaváčková, Vladimíra; Floková, Kristýna; Novák, Ondřej; Nauš, Jan

    2012-05-01

    Burning the terminal leaflet of younger tomato (Lycopersicon esculentum Mill.) leaf caused local and systemic changes in the surface electrical potential (SEP) and gas exchange (GE) parameters. The local and systemic accumulation of endogenous abscisic acid (ABA) and jasmonic acid (JA) was measured 85 min after burning. The experiments were conducted with wild type (WT) plants, ABA-deficient mutant sitiens (SIT) and ABA pre-treated SIT plants (SITA). First changes in SEP were detected within 1.5 min after burning and were followed by a decrease in GE parameters within 3-6 min in WT, SIT and SITA plants. GE and SEP time courses of SIT were different and wave amplitudes of SEP of SIT were lower compared to WT and SITA. ABA content in WT and SITA control plants was similar and substantially higher compared to SIT, JA content was similar among WT, SIT and SITA. While changes in the ABA content in systemic leaves have not been recorded after burning, the systemic JA content was substantially increased in WT and more in SIT and SITA. The results suggest that ABA content governs the systemic reaction of GE and the SEP shape upon local burning. ABA, JA and SEP participate in triggering the GE reaction. The ABA shortage in the SIT in the reaction to burning is partly compensated by an enhanced JA accumulation. This JA compensation is maintained even in SIT endogenously supplied with ABA. A correlation between the systemic JA content and changes in GE parameters or SEP was not found.

  19. Burn Pits

    Science.gov (United States)

    ... Enter ZIP code here Enter ZIP code here Burn Pits Burn Pits Registry Studies Photo: U.S. Department ... the health of deployed Veterans. Health effects from burn pit smoke Toxins in burn pit smoke may ...

  20. Burn Institute

    Science.gov (United States)

    ... Now Help keep local seniors safe from fire! Burn Survivor Support If you are reading this, chances ... year – a burn injury. Learn more Fire and Burn Prevention Each year, the Burn Institute provides fire ...

  1. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a second of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last six years. The main core of the results are obtained by PhD students...... researching electrical engineering topics related to using underground cables for power transmission at EHV level and including the 420 kV level. The research topics were laid down by ET/AAU and Energinet.dk in the DANPAC (DANish Power systems with Ac Cables) research project. The main topics are discussed...

  2. Dual design resistor for high voltage conditioning and transmission lines

    Science.gov (United States)

    Siggins, Timothy Lynn [Newport News, VA; Murray, Charles W [Hayes, VA; Walker, Richard L [Norfolk, VA

    2007-01-23

    A dual resistor for eliminating the requirement for two different value resistors. The dual resistor includes a conditioning resistor at a high resistance value and a run resistor at a low resistance value. The run resistor can travel inside the conditioning resistor. The run resistor is capable of being advanced by a drive assembly until an electrical path is completed through the run resistor thereby shorting out the conditioning resistor and allowing the lower resistance run resistor to take over as the current carrier.

  3. Bilateral Electrical Cataract: A Case Report

    Directory of Open Access Journals (Sweden)

    Selçuk Sızmaz

    2011-06-01

    Full Text Available To present a rare complication, such as bilateral cataracts, in a man who sustained a high-voltage electrical injury. A 35- year-old man was admitted with a complaint of decrease in visual acuity. He had a history of a contact with a power line carrying 30.000 volts of electricity while working at a construction site. Examination at a burn center revealed second-degree facial, neck and left foot burns. One month later, the patient underwent amputation of fourth and fifth toes of his left foot. During the next 6 months, he noted decreasing vision in both eyes. Ocular examination 1 year after the accident revealed that the patient’s visual acuity had deteriorated to 1/10 in both eyes. The cornea on the left eye showed superficial punctate opacities. The lenses in both eyes had anterior subcapsular cortical lens opacities and posterior subcapsular opacities. Uncomplicated bilateral phacoemulsification surgery with intraocular lens implantation was performed and the patient’s visual acuity returned to 10/10 in both eyes. We noted that the fundus remained normal in both eyes. Electrical cataracts are still a serious potential complication that may occur after electrical injury. Awareness of this by burn team members is important for providing optimal treatment to those who have suffered an electrical injury. (Turk J Ophthalmol 2011; 41: 197-9

  4. Design of load-to-failure tests of high-voltage insulation breaks for ITER's cryogenic network

    Science.gov (United States)

    Langeslag, S. A. E.; Rodriguez Castro, E.; Aviles Santillana, I.; Sgobba, S.; Foussat, A.

    2015-12-01

    The development of new generation superconducting magnets for fusion research, such as the ITER experiment, is largely based on coils wound with so-called cable-in-conduit conductors. The concept of the cable-in-conduit conductor is based on a direct cooling principle, by supercritical helium, flowing through the central region of the conductor, in close contact with the superconducting strands. Consequently, a direct connection exists between the electrically grounded helium coolant supply line and the highly energised magnet windings. Various insulated regions, constructed out of high-voltage insulation breaks, are put in place to isolate sectors with different electrical potential. In addition to high voltages and significant internal helium pressure, the insulation breaks will experience various mechanical forces resulting from differential thermal contraction phenomena and electro-magnetic loads. Special test equipment was designed, prepared and employed to assess the mechanical reliability of the insulation breaks. A binary test setup is proposed, where mechanical failure is assumed when leak rate of gaseous helium exceeds 10-9·Pa·m3/s. The test consists of a load-to-failure insulation break charging, in tension, while immersed in liquid nitrogen at the temperature of 77 K. Leak tightness during the test is monitored by measuring the leak rate of the gaseous helium, directly surrounding the insulation break, with respect to the existing vacuum inside the insulation break. The experimental setup is proven effective, and various insulation breaks performed beyond expectations.

  5. Electron Emission from Ferroelectric/Antiferroelectric Cathodes Excited by Short High-Voltage Pulses

    CERN Document Server

    Benedek, G; Handerek, J; Riege, H

    1997-01-01

    Un-prepoled Lead Zirconate Titanate Lanthanum doped-PLZT ferroelectric cathodes have emitted intense current pulses under the action of a high voltage pulse of typically 8 kV/cm for PLZT of 8/65/35 composition and 25 kV/cm for PLZT of 4/95/5 composition. In the experiments described in this paper, the exciting electric field applied to the sample is directed from the rear surface towards the emitting surface. The resulting emission is due to an initial field emission from the metal of the grid deposited over the emitting surface with the consequent plasma formation and the switching of ferroelectric domains. These electrons may be emitted directly form the crystal or from the plasma. This emission requires the material in ferroelectric phase. In fact, PLZT cathodes of the 8/65/35 type, that is with high Titanium content, showing ferroelectric-paraelectric phase sequence, emit at room temperature, while PLZT cathodes of the 4/95/5 type, that is with low Titanium content, having antiferro-ferro-paraelectric pha...

  6. Testing to Investigate Stress-LifetimeCharacteristics of High Voltage Printed Circuit Boards

    Science.gov (United States)

    El Korashy, Oliver; Franke, Andreas; Gollor, Matthias

    2014-08-01

    Printed circuit boards (PCBs) are typically used in all electronic equipment, including those conditioning or controlling high voltage (HV) for space satellite applications. With the use of new subsystems that require higher voltages (generally several hundred volts up to tens of kV), stress-lifetime issues are becoming more complex. In order to allow compact design and cost efficient production of HV modules, there is an increasing demand to improve the design of PCBs with encapsulation or conformal coating at higher voltages.Within a PCB there are a number of electrical field interfaces each of which can have individual stress- lifetime characteristics, and the influence of environmental aging should also be considered, which means a large number of sample types should be tested to gain experimental evidence to define the margin for each interface. This paper demonstrates a method to test multiple samples at a fixed DC voltage stress until the event of a breakdown, and presents test results from 6 single-sided encapsulated PCB samples.

  7. Comparative study of high voltage bushing designs suitable for apparatus containing cryogenic helium gas

    Science.gov (United States)

    Rodrigo, H.; Graber, L.; Kwag, D. S.; Crook, D. G.; Trociewitz, B.

    2013-10-01

    The high voltage bushing forms a critical part of any termination on cables, transformers and other power system devices. Cryogenic entities such as superconducting cables or fault current limiters add more complexity to the design of the bushing. Even more complex are bushings designed for superconducting devices which are cooled by high pressure helium gas. When looking for a bushing suitable for dielectric cable tests in a helium gas cryostat no appropriate device could be found that fulfilled the criterion regarding partial discharge inception voltage level. Therefore we decided to design and manufacture a bushing in-house. In the present work we describe the dielectric tests and operational experience on three types of bushings: One was a modified commercially available ceramics feed through which we adopted for our special need. The second bushing was made of an epoxy resin, with an embedded copper squirrel cage arrangement at the flange, extending down about 30 cm into the cold end of the bushing. This feature reduced the electric field on the surface of the bushing to a negligible value. The third bushing was based on a hollow body consisting of glass fiber reinforced polymer and stainless steel filled with liquid nitrogen. The measurements showed that the dielectric quality of all three bushings exceeded the requirements for the intended purpose. The partial discharge (PD) data from these studies will be used for the design and fabrication of a cable termination for a specialized application on board a US Navy ship.

  8. Effect of high voltage atmospheric cold plasma on white grape juice quality.

    Science.gov (United States)

    Pankaj, Shashi Kishor; Wan, Zifan; Colonna, William; Keener, Kevin M

    2017-09-01

    This study focuses on the effects of novel, non-thermal high voltage atmospheric cold plasma (HVACP) processing on the quality of grape juice. A quality-based comparison of cold plasma treatment with thermal pasteurization treatment of white grape juice was done. HVACP treatment of grape juice at 80 kV for 4 min resulted in a 7.4 log10 CFU mL(-1) reduction in Saccharomyces cerevisiae without any significant (P > 0.05) change in pH, acidity and electrical conductivity of the juice. An increase in non-enzymatic browning was observed, but total color difference was very low and within acceptable limits. Spectrophotometric measurements showed a decrease in total phenolics, total flavonoids, DPPH free radical scavenging and antioxidant capacity, but they were found to be comparable to those resulting from thermal pasteurization. An increase in total flavonols was observed after HVACP treatments. HVACP treatment of white grape juice at 80 kV for 2 min was found to be comparable to thermal pasteurization in all analyzed quality attributes. HVACP has shown the potential to be used as an alternative to thermal treatment of white grape juice. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  9. Mechanism of formation of subnanosecond current front in high-voltage pulse open discharge

    Science.gov (United States)

    Schweigert, I. V.; Alexandrov, A. L.; Zakrevsky, Dm. E.; Bokhan, P. A.

    2014-11-01

    The mechanism of subnanosecond current front rise observed previously in the experiment in high-voltage pulse open discharge in helium is studied in kinetic particle-in-cell simulations. The Boltzmann equations for electrons, ions, and fast atoms are solved self-consistently with the Poisson equations for the electrical potential. The partial contributions to the secondary electron emission from the ions, fast atoms, photons, and electrons, bombarding the electrode, are calculated. In simulations, as in the experiment, the discharge glows between two symmetrical cathodes and the anode grid in the midplane at P =6 Torr and the applied voltage of 20 kV. The electron avalanche development is considered for two experimental situations during the last stage of breakdown: (i) with constant voltage and (ii) with decreasing voltage. For case (i), the subnanosecond current front rise is set by photons from the collisional excitation transfer reactions. For the case (ii), the energetic electrons swamp the cathode during voltage drop and provide the secondary electron emission for the subnanosecond current rise, observed in the experiment.

  10. Proposed high voltage power supply for the ITER relevant lower hybrid current drive system

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, P.K., E-mail: pramod@ipr.res.in [Institute for Plasma Research, Bhat, Gandhinagar, Gujarat (India); Kazarian, F.; Garibaldi, P.; Gassman, T. [ITER Organization, CS 90 046, 13067 Saint-Paul-Les-Durance (France); Artaud, J.F. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Bae, Y.S. [National Fusion Research Institute, Daejeon (Korea, Republic of); Belo, J. [Associacao Euratom-IST, Centro de Fusao Nuclear, Lisboa (Portugal); Berger-By, G.; Bernard, J.M.; Cara, Ph. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Cardinali, A.; Castaldo, C.; Ceccuzzi, S.; Cesario, R. [Associazione Euratom-ENEA sulla Fusione, CR Frascati, Rome (Italy); Decker, J.; Delpech, L.; Ekedahl, A.; Garcia, J.; Goniche, M.; Guilhem, D. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France)

    2011-10-15

    In the framework of the EFDA task HCD-08-03-01, the ITER lower hybrid current drive (LHCD) system design has been reviewed. The system aims to generate 24 MW of RF power at 5 GHz, of which 20 MW would be coupled to the plasmas. The present state of the art does not allow envisaging a unitary output of the klystrons exceeding 500 kW, so the project is based on 48 klystron units, leaving some margin when the transmission lines losses are taken into account. A high voltage power supply (HVPS), required to operate the klystrons, is proposed. A single HVPS would be used to feed and operate four klystrons in parallel configuration. Based on the above considerations, it is proposed to design and develop twelve HVPS, based on pulse step modulator (PSM) technology, each rated for 90 kV/90 A. This paper describes in details, the typical electrical requirements and the conceptual design of the proposed HVPS for the ITER LHCD system.

  11. An Ultra-Compact Marx-Type High-Voltage Generator

    Energy Technology Data Exchange (ETDEWEB)

    Goerz, D; Ferriera, T; Nelson, D; Speer, R; Wilson, M

    2001-06-15

    This paper discusses the design of an ultra-compact, Marx-type, high-voltage generator. This system incorporates high-performance components that are closely coupled and integrated into an extremely compact assembly. Low profile, custom ceramic capacitors with coplanar extended electrodes provide primary energy storage. Low-inductance, spark-gap switches incorporate miniature gas cavities imbedded within the central region of the annular shaped capacitors, with very thin dielectric sections separating the energy storage capacitors. Carefully shaped electrodes and insulator surfaces are used throughout to minimize field enhancements, reduce fields at triple-point regions, and enable operation at stress levels closer to the intrinsic breakdown limits of the dielectric materials. Specially shaped resistors and inductors are used for charging and isolation during operation. Forward-coupling ceramic capacitors are connected across successive switch-capacitor-switch stages to assist in switching. Pressurized SF, gas is used for electrical insulation in the spark-gap switches and throughout the unit. The pressure housing is constructed entirely of dielectric materials, with segments that interlock with the low-profile switch bodies to provide an integrated support structure for all of the components. This ultra-compact Marx generator employs a modular design that can be sized as needed for a particular application. Units have been assembled with 4, 10, and 30 stages and operated at levels up to 100 kV per stage.

  12. Power Improvement of Transmission Line Using High Voltage Direct Current (Hvdc Transmission System

    Directory of Open Access Journals (Sweden)

    Lasisi, H

    2016-08-01

    Full Text Available The use of long EHV (Extremely High Voltage ac lines for the transmission of electrical energy increases the line reactance and susceptance which limits the thermal loadings on the line in order to keep sufficient margin against transient instability. With the scheme proposed in this paper, it is possible to load the lines very close to their limit with zero reactance and susceptance. The conductors are allowed to carry usual ac along with dc superimposed on it. The added dc power flow does not cause any transient instability. The scheme comprises a twelve-pulse bridge rectifier, dc-links, pulse width modulated (PSW-voltage sourced inverter (VSI and converter transformers. The master current controller is used to implement the scheme which senses ac current and regulates the dc current orders for converters online such that conductor current never exceeds its thermal limit. This paper gives the feasibility of converting a double circuit ac line into composite ac–dc power transmission line given the advantage of stability improvement, damping oscillations, voltage stabilization and reactive power compensation for ac weak buses. Simulation and experimental studies using MATLAB (Matrix Laboratory are carried out for the coordinated control as well as independent control of ac and dc power transmissions.

  13. Diagnostics and testing of high voltage cable systems

    Energy Technology Data Exchange (ETDEWEB)

    Hyvoenen, P.; Oyegoke, B.; Aro, M.

    2003-07-01

    Reliability demands on electricity generation and distribution are increasing. Power utilities have faced new challenges due to liberalisation of electricity markets, increasing authors regulation and new claims for compensation of unexpected power shut downs. As a result power utilities have to concentrate more on asset management to reduce costs, to postpone investments, to optimise technical management keeping at the same time reliability and power quality at high level. Nowadays it is important to do right things at right place at right time. Maintenance strategy is changing from predictive or repairing maintenance to the condition based maintenance (CBM). Success of CBM depends partly on how good and reliable tools are available to determine condition of electrical apparatus. Cables have been used in electricity distribution since beginning of 20th century. Oldest still in use cables in Finland has been installed late 1940's. Nowadays almost all new distribution systems in urban areas are done using cables. Wide variety of cables are in use. Knowledge of condition and history of cables is not so well documented. Professional skill to install cable systems is disappearing due to outsourcing of maintenance groups. There is a worry about increasing amount of after installation faults due to loosing of professional skills to install cable systems. Wide variety of cable insulation systems and large variety in ages of cables still in use will place hard challenges for cable condition assessment. Earlier studies showed that measurement of insulation resistance is almost only diagnostic measurement performed to cable systems. Knowledge and experience of new diagnostic method is not so widely distributed. Based on previous project, dielectric response (DR) measurement and partial discharge (PD) measurement seemed to be most promising tools for the condition assessment of cable systems. Increased moisture content in oil-paper insulated cable or water trees in

  14. A novel high voltage start up circuit for an integrated switched mode power supply

    Energy Technology Data Exchange (ETDEWEB)

    Hu Hao; Chen Xingbi, E-mail: huhao21@uestc.edu.c [State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu 610054 (China)

    2010-09-15

    A novel high voltage start up circuit for providing an initial bias voltage to an integrated switched mode power supply (SMPS) is presented. An enhanced mode VDMOS transistor, the gate of which is biased by a floating p-island, is used to provide start up current and sustain high voltage. An NMOS transistor having a high source to ground breakdown voltage is included to extend the bias voltage range to the SMPS. Simulation results indicate that the high voltage start up circuit can start and restart as designed. The proposed structure is believed to be more energy saving and cost-effective compared with other solutions. (semiconductor devices)

  15. SEMICONDUCTOR DEVICES: A novel high voltage start up circuit for an integrated switched mode power supply

    Science.gov (United States)

    Hao, Hu; Xingbi, Chen

    2010-09-01

    A novel high voltage start up circuit for providing an initial bias voltage to an integrated switched mode power supply (SMPS) is presented. An enhanced mode VDMOS transistor, the gate of which is biased by a floating p-island, is used to provide start up current and sustain high voltage. An NMOS transistor having a high source to ground breakdown voltage is included to extend the bias voltage range to the SMPS. Simulation results indicate that the high voltage start up circuit can start and restart as designed. The proposed structure is believed to be more energy saving and cost-effective compared with other solutions.

  16. The 100 kV Faraday cage (High Voltage Deck) for the SPIDER experiment

    Energy Technology Data Exchange (ETDEWEB)

    Boldrin, Marco, E-mail: marco.boldrin@igi.cnr.it [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete S.p.A.), Corso Stati Uniti 4, 35127 Padova (Italy); Grando, Luca; Pesce, Alberto; Recchia, Mauro; Toigo, Vanni [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete S.p.A.), Corso Stati Uniti 4, 35127 Padova (Italy); Gutierrez, Daniel; Simon, Muriel [Fusion for Energy, c/o Josep Pla 2, 08019 Barcelona (Spain); Faoro, Giovanni; Guion, Andrea; Maggiora, Edoardo; Pedron, Diego [COELME – Costruzioni Elettromeccaniche S.p.A., via G. Galilei no. 1/2, 30036 S. Maria di Sala, Venezia (Italy); Roman, Anita [Studio di Ingegneria RS s.r.l., Viale dell’Arcella 1, 35153 Padova (Italy); Decamps, Hans [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2015-10-15

    Highlights: • A 100 keV experiment is under construction to optimize ITER NBI Ion Source. • The Ion Source Power Supplies are hosted inside a wide −100 kVdc Faraday cage (HVD). • The paper reports on the design solutions of the HVD. • Electrostatic and electromagnetic analyses are presented. • Procurement activities status is reported. - Abstract: In order to optimize the design and operation of the Ion Source for the ITER Neutral Beam Injector (NBI), a dedicated 100 keV Ion Source, identified as Source for the Production of Ions of Deuterium Extracted from RF plasma (SPIDER), is under construction in the Neutral Beam Test Facility, at the Consorzio RFX premises, in Padua, Italy. The Ion Source, polarized at −112 kVdc voltage, will produce negative ions (Deuterium D{sup −} or Hydrogen H{sup −}) which, extracted from the Plasma Grid with an extraction voltage up to 12 keV, are accelerated up to 100 keV by the 100 kVdc Power Supply (100 kV PS). The required Ion Source and the Extraction Power Supplies (ISEPS) system and the associated diagnostics are hosted inside a High Voltage Deck (HVD), a −100 kVdc air-insulated Faraday cage. These power supplies and various diagnostics and control equipment are connected to the Ion Source by means of a High Voltage Transmission Line (TL). The HVD (procurement started mid 2013; delivery on site in the second half of 2014) will consist of a wide structure (13 m (L) × 11 m (W) × 5 m (H)), designed to support the weight of the ISEPS components, mounted on supporting insulators and clad with a conductive metal sheet in order to reduce the electromagnetic interference (EMI). The paper reports on the design solutions of the HVD focusing on insulation, mechanical, thermal and EMI issues. The details of the main HVD interfaces with the TL and with insulating transformer are also described. Finite Element (FE) analyses have been performed, on the one hand, to verify the configuration from the electrostatic point of

  17. High voltage MOSFET devices and methods of making the devices

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Sujit; Matocha, Kevin; Chatty, Kiran

    2015-12-15

    A SiC MOSFET device having low specific on resistance is described. The device has N+, P-well and JFET regions extended in one direction (Y-direction) and P+ and source contacts extended in an orthogonal direction (X-direction). The polysilicon gate of the device covers the JFET region and is terminated over the P-well region to minimize electric field at the polysilicon gate edge. In use, current flows vertically from the drain contact at the bottom of the structure into the JFET region and then laterally in the X direction through the accumulation region and through the MOSFET channels into the adjacent N+ region. The current flowing out of the channel then flows along the N+ region in the Y-direction and is collected by the source contacts and the final metal. Methods of making the device are also described.

  18. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a first of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last 6 years. The main core of the results are obtained by PhD students research......This paper is a first of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last 6 years. The main core of the results are obtained by PhD students...... researching electrical engineering topics related to using underground cables for power transmission at EHV level and including the 420 kV level. The research topics were laid down by ET/AAU and Energinet.dk in the DANPAC (DANish Power systems with AC Cables) research project. The main topics are discussed...

  19. High-voltage atmospheric breakdown across intervening rutile dielectrics.

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, Kenneth Martin; Simpson, Sean; Coats, Rebecca Sue; Jorgenson, Roy Eberhardt; Hjalmarson, Harold Paul; Pasik, Michael Francis

    2013-09-01

    This report documents work conducted in FY13 on electrical discharge experiments performed to develop predictive computational models of the fundamental processes of surface breakdown in the vicinity of high-permittivity material interfaces. Further, experiments were conducted to determine if free carrier electrons could be excited into the conduction band thus lowering the effective breakdown voltage when UV photons (4.66 eV) from a high energy pulsed laser were incident on the rutile sample. This report documents the numerical approach, the experimental setup, and summarizes the data and simulations. Lastly, it describes the path forward and challenges that must be overcome in order to improve future experiments for characterizing the breakdown behavior for rutile.

  20. Effect of extremely low frequency electromagnetic field exposure on sleep quality in high voltage substations.

    Science.gov (United States)

    Barsam, Tayebeh; Monazzam, Mohammad Reza; Haghdoost, Ali Akbar; Ghotbi, Mohammad Reza; Dehghan, Somayeh Farhang

    2012-11-30

    This study aims to investigate the effect of extremely low frequency electromagnetic fields exposure on sleep quality in high voltage substations (132, 230 and 400 KV) in Kerman city and the suburbs. For this purpose, the electric field intensity and magnetic flux density were measured in different parts of substations, and then the occupational exposure was estimated by averaging electric field intensity and magnetic flux density in a shift work. The cases comprised 67 workers who had been exposed to electromagnetic fields in age range of 24-57 and the controls were 110 persons the age ranged 24-50 years. Sleep quality of both groups was evaluated by the Pittsburgh Sleep Quality Index questionnaire (PSQI). Finally, these data were subjected to statistical analysis. The results indicated that 90.5% of cases and 85.3% of controls had the poor quality sleep according to PSQI (P-value=0.615). Total sleep quality score mean for the case and control groups were 10.22 ± 3.4 and 9.74 ± 3.62 (P-value=0.415) ,respectively. Meantime to fall asleep for cases(35.68 ± 26.25 min) was significantly higher than for controls (28.89 ± 20.18 min) (P-value=0.002). Cases had average sleep duration of 5.49 ± 1.31 hours, which was lower ascompared with control subjects (5.90 ± 1.67hours). Although there was a higher percentage for the case group with poor sleep quality than the control group, but no statistically significant difference was observed.

  1. Effect of extremely low frequency electromagnetic field exposure on sleep quality in high voltage substations

    Directory of Open Access Journals (Sweden)

    Barsam Tayebeh

    2012-11-01

    Full Text Available Abstract This study aims to investigate the effect of extremely low frequency electromagnetic fields exposure on sleep quality in high voltage substations (132, 230 and 400 KV in Kerman city and the suburbs. For this purpose, the electric field intensity and magnetic flux density were measured in different parts of substations, and then the occupational exposure was estimated by averaging electric field intensity and magnetic flux density in a shift work. The cases comprised 67 workers who had been exposed to electromagnetic fields in age range of 24–57 and the controls were 110 persons the age ranged 24–50 years. Sleep quality of both groups was evaluated by the Pittsburgh Sleep Quality Index questionnaire (PSQI. Finally, these data were subjected to statistical analysis. The results indicated that 90.5% of cases and 85.3% of controls had the poor quality sleep according to PSQI (P-value=0.615. Total sleep quality score mean for the case and control groups were 10.22 ± 3.4 and 9.74 ± 3.62 (P-value=0.415 ,respectively. Meantime to fall asleep for cases(35.68 ± 26.25 min was significantly higher than for controls (28.89 ± 20.18 min (P-value=0.002. Cases had average sleep duration of 5.49 ± 1.31 hours, which was lower ascompared with control subjects (5.90 ± 1.67hours. Although there was a higher percentage for the case group with poor sleep quality than the control group, but no statistically significant difference was observed.

  2. Method and system for a gas tube switch-based voltage source high voltage direct current transmission system

    Energy Technology Data Exchange (ETDEWEB)

    She, Xu; Chokhawala, Rahul Shantilal; Zhou, Rui; Zhang, Di; Sommerer, Timothy John; Bray, James William

    2016-12-13

    A voltage source converter based high-voltage direct-current (HVDC) transmission system includes a voltage source converter (VSC)-based power converter channel. The VSC-based power converter channel includes an AC-DC converter and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and a DC-AC inverter include at least one gas tube switching device coupled in electrical anti-parallel with a respective gas tube diode. The VSC-based power converter channel includes a commutating circuit communicatively coupled to one or more of the at least one gas tube switching devices. The commutating circuit is configured to "switch on" a respective one of the one or more gas tube switching devices during a first portion of an operational cycle and "switch off" the respective one of the one or more gas tube switching devices during a second portion of the operational cycle.

  3. Burn Injuries: Burn Depth, Physiopathology and Type of Burns

    Directory of Open Access Journals (Sweden)

    Kemalettin Koltka

    2011-07-01

    Full Text Available A significant burn injury is a serious and mortal event. The most important threat to life is hypovolemic shock with complex pathophysiologic mechanisms. Burn depth is classified as first, second, or third degree. Local inflammatory response results a vasodilatation and an increase in vascular permeability. A burn injury is a three dimensional ischemic wound. Zone of coagulation is the zone with maximum damage. Zone of stasis consists of damaged but viable tissues, the tissue is salvageable. In zone of hyperemia tissue perfusion is increased. At the beginning, cardiac output falls and systemic vascular resistance increases; cardiac performance improves as hypovolemia is corrected with fluid resuscitation. While cardiac output increases systemic vascular resistance falls below normal values and a hypermetabolic state develops. Pulmonary vascular resistance increases immediately after thermal injury and this is more prolonged. To avoid secondary pulmonary complications, the smallest resuscitation volume of fluids that maintains adequate tissue perfusion should be given. Changes parallel to the cardiovascular response develop in other organ systems. The reasons of burn injury can be thermal, electrical, chemical or radiation. It is important to know the exact mechanism of burn injury because of different therapies for a specific cause. In this review information about burn depth, local and systemic responses to burn injury and major causes of burn injury are presented. (Journal of the Turkish Society Intensive Care 2011; 9 Suppl:1-6

  4. Preparation methodology and possible treatments for improved ceramics for high voltage vacuum applications

    CERN Document Server

    Tan, J

    1998-01-01

    The flashover characteristics of an insulator bridged high voltage vacuum gap can play an important role in the overall performance of a high voltage device, for example in the extreme environments of high energy particle accelerators. The detailed preparation of the insulators is, at present, governed by the commercial production methods and by standard bulk cleaning processes, which for a particular application may be far from optimum. The influence of the mechanical preparation, thermal history and particular cleaning technique have been investigated for commercially available alumina samples, with measurement of surface characteristics by scanning electron microscopy and laser diffraction, measurement of the secondary electron emission curve and analysis of the high voltage performance with the possibility of applied fields up to 200kV/cm. The results of the different measurements are discussed in the overall context of the problems encountered in the full sized high voltage devices, and suggestions are m...

  5. HIGH VOLTAGE ENVIRONMENTAL APPLICATIONS, INC.ELECTRON BEAM TECHNOLOGY - INNOVATIVE TECHNOLOGY EVALUATION REPORT

    Science.gov (United States)

    This report evaluates a high-voltage electron beam (E-beam) technology's ability to destroy volatile organic compounds (VOCs) and other contaminants present in liquid wastes. Specifically, this report discusses performance and economic data from a Superfund Innovative Technology...

  6. Circuits protection against interferences in high voltage substations; Protecao de circuitos contra interferencias em subestacoes

    Energy Technology Data Exchange (ETDEWEB)

    Hamada, Massayuki [Consultas e Aplicacoes de Engenharia Eletrica Ltda. (CAEEL) (Brazil)

    1989-12-01

    This paper makes a brief analysis of the different phenomena which may cause electromagnetic interference in high voltage substations and suggests adequate solutions to the problem according to the different events that may occur. 5 refs., 1 fig.

  7. Automatic Functional Step-up System in High-Voltage Installation

    Institute of Scientific and Technical Information of China (English)

    陈方泉; 严一白; 宋进; 林财兴

    2004-01-01

    This article describes automatic functional step-up systems in high-voltage installation, with emphases on functional process of step-up and step-down, two-circuit control and elimination of tip burr voltage.

  8. Unique Power Dense, Configurable, Robust, High-Voltage Power Supplies Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Princeton Power will develop and deliver three small, lightweight 50 W high-voltage power supplies that have a configurable output voltage range from 500 to 50 kVDC....

  9. Evaluation of Epoxy Nanocomposites for High Voltage Insulation

    Science.gov (United States)

    Iyer, Ganpathy

    Polymeric materials containing nanometer (nm) size particles are being introduced to provide compact shapes for low and medium voltage insulation equipment. The nanocomposites may provide superior electrical performance when compared with those available currently, such as lower dielectric losses and increased dielectric strength, tracking and erosion resistance, and surface hydrophobicity. All of the above mentioned benefits can be achieved at a lower filler concentration (resistance tests were conducted over 500 hours to monitor degradation in the samples due to corona. These tests revealed improvements in partial discharge endurance of nanocomposite samples. These improvements could not be adequately explained using a macroscopic quantity such as thermal conductivity. Thermo gravimetric analysis (TGA) showed higher weight loss initiation temperatures for nanofilled samples which is in agreement with the corona resistance experimental results. Theoretical models have also been developed in this work to complement the results of the corona resistance experiment and the TGA analysis. Degradation model was developed to map the erosion path using Dijkstra's shortest path algorithm. A thermal model was developed to calculate the localized temperature distribution in the micro and nano-filled samples using the PDE toolbox in MATLAB. Both the models highlight the fact that improvement in nanocomposites is not limited to the filler concentrations that were tested experimentally.

  10. Results of the 2015 testbeam of a 180 nm AMS High-Voltage CMOS sensor prototype

    CERN Document Server

    Benoit, M; de Mendizabal, J. Bilbao; Chen, H; Chen, K; Di Bello, F.A; Ferrere, D; Golling, T; Gonzalez-Sevilla, S; Iacobucci, G; Lanni, F; Liu, H; Meng, L; Miucci, A; Muenstermann, D; Nessi, M; Peric, I; Rimoldi, M; Ristic, B; Pinto, M. Vicente Barrero; Vossebeld, J; Weber, M; Wu, W; Xu, L

    2016-01-01

    Active pixel sensors based on the High-Voltage CMOS technology are being investigated as a viable option for the future pixel tracker of the ATLAS experiment at the High-Luminosity LHC. This paper reports on the testbeam measurements performed at the H8 beamline of the CERN Super Proton Synchrotron on a High-Voltage CMOS sensor prototype produced in 180 nm AMS technology. Results in terms of tracking efficiency and timing performance, for different threshold and bias conditions, are shown.

  11. Program-Controlled High Voltage Module in Active Voltage Dividers(AVD) for MPGD

    CERN Document Server

    Ginting, Muhammad Fadhil

    2016-01-01

    Micro Pattern Gas Detectors (MPGD) applications are rapidly developing and became an important part of upgrades for the LHC detectors. RD51/CERN have worked on Active Voltage Divider (AVD) technology for multistage MPGDs, One of the next developments for the AVD is to design and integrate high voltage module in a single box. The Program-Controlled High Voltage Module, part of one AIDA2020 project, has been successfully designed and developed, and can be integrated in AVD design.

  12. Process engineering of high voltage alginate encapsulation of mesenchymal stem cells

    Energy Technology Data Exchange (ETDEWEB)

    Gryshkov, Oleksandr, E-mail: gryshkov@imp.uni-hannover.de [Institute for Multiphase Processes, Leibniz University Hannover, D-30167 Hannover (Germany); Pogozhykh, Denys, E-mail: pogozhykh@imp.uni-hannover.de [Institute for Multiphase Processes, Leibniz University Hannover, D-30167 Hannover (Germany); Zernetsch, Holger, E-mail: zernetsch@imp.uni-hannover.de [Institute for Multiphase Processes, Leibniz University Hannover, D-30167 Hannover (Germany); Hofmann, Nicola, E-mail: hofmann@imp.uni-hannover.de [Institute for Multiphase Processes, Leibniz University Hannover, D-30167 Hannover (Germany); Mueller, Thomas, E-mail: mueller.thomas@mh-hannover.de [Institute for Transfusion Medicine, Medical School Hannover, D-30625 Hannover (Germany); Glasmacher, Birgit, E-mail: glasmacher@imp.uni-hannover.de [Institute for Multiphase Processes, Leibniz University Hannover, D-30167 Hannover (Germany)

    2014-03-01

    Encapsulation of stem cells in alginate beads is promising as a sophisticated drug delivery system in treatment of a wide range of acute and chronic diseases. However, common use of air flow encapsulation of cells in alginate beads fails to produce beads with narrow size distribution, intact spherical structure and controllable sizes that can be scaled up. Here we show that high voltage encapsulation (≥ 15 kV) can be used to reproducibly generate spherical alginate beads (200–400 μm) with narrow size distribution (± 5–7%) in a controlled manner under optimized process parameters. Flow rate of alginate solution ranged from 0.5 to 10 ml/h allowed producing alginate beads with a size of 320 and 350 μm respectively, suggesting that this approach can be scaled up. Moreover, we found that applied voltages (15–25 kV) did not alter the viability and proliferation of encapsulated mesenchymal stem cells post-encapsulation and cryopreservation as compared to air flow. We are the first who employed a comparative analysis of electro-spraying and air flow encapsulation to study the effect of high voltage on alginate encapsulated cells. This report provides background in application of high voltage to encapsulate living cells for further medical purposes. Long-term comparison and work on alginate–cell interaction within these structures will be forthcoming. - Highlights: • High voltage alginate encapsulation of mesenchymal stem cells (MSCs) was designed. • Reproducible and spherical alginate beads were generated via high voltage. • Air flow encapsulation was utilized as a comparative approach to high voltage. • High voltage did not alter the viability and proliferation of encapsulated MSCs. • High voltage encapsulation can be scaled up and applied in cell-based therapy.

  13. Capacitance of High-Voltage Coaxial Cable in Plasma Immersion Ion Implantation

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Plasma immersion ion implantation (PIII) is an excellent technique for the surface modification of complex-shaped components. Owing to pulsed operation mode of the high voltage and large slew rate, the capacitance on the high-voltage coaxial cable can be detrimental to the processand cannot be ignored. In fact, a significant portion of the rise-time/fall-time of the implantation voltage pulse and big initial current can be attributed to the coaxial cable.

  14. High-voltage, high-current, solid-state closing switch

    Energy Technology Data Exchange (ETDEWEB)

    Focia, Ronald Jeffrey

    2017-08-22

    A high-voltage, high-current, solid-state closing switch uses a field-effect transistor (e.g., a MOSFET) to trigger a high-voltage stack of thyristors. The switch can have a high hold-off voltage, high current carrying capacity, and high time-rate-of-change of current, di/dt. The fast closing switch can be used in pulsed power applications.

  15. An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.

    Energy Technology Data Exchange (ETDEWEB)

    Litzenberger, Wayne; Lava, Val

    1994-08-01

    References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

  16. 30 CFR 75.803 - Fail safe ground check circuits on high-voltage resistance grounded systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe ground check circuits on high-voltage resistance grounded systems. 75.803 Section 75.803 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... High-Voltage Distribution § 75.803 Fail safe ground check circuits on high-voltage resistance...

  17. A Low Input Current and Wide Conversion Ratio Buck Regulator with 75% Efficiency for High-Voltage Triboelectric Nanogenerators

    Science.gov (United States)

    Luo, Li-Chuan; Bao, De-Chun; Yu, Wu-Qi; Zhang, Zhao-Hua; Ren, Tian-Ling

    2016-01-01

    It is meaningful to research the Triboelectric Nanogenerators (TENG), which can create electricity anywhere and anytime. There are many researches on the structures and materials of TENG to explain the phenomenon that the maximum voltage is stable and the current is increasing. The output voltage of the TENG is high about 180-400 V, and the output current is small about 39 μA, which the electronic devices directly integration of TENG with Li-ion batteries will result in huge energy loss due to the ultrahigh TENG impedance. A novel interface circuit with the high-voltage buck regulator for TENG is introduced firstly in this paper. The interface circuit can transfer the output signal of the TENG into the signal fit to a lithium ion battery. Through the circuit of the buck regulator, the average output voltage is about 4.0 V and the average output current is about 1.12 mA. Further, the reliability and availability for the lithium ion battery and the circuit are discussed. The interface circuit is simulated using the Cadence software and verified through PCB experiment. The buck regulator can achieve 75% efficiency for the High-Voltage TENG. This will lead to a research hot and industrialization applications.

  18. Tesla’s high voltage and high frequency generators with oscillatory circuits

    Directory of Open Access Journals (Sweden)

    Cvetić Jovan M.

    2016-01-01

    Full Text Available The principles that represent the basics of the work of the high voltage and high frequency generator with oscillating circuits will be discussed. Until 1891, Tesla made and used mechanical generators with a large number of extruded poles for the frequencies up to about 20 kHz. The first electric generators based on a new principle of a weakly coupled oscillatory circuits he used for the wireless signal transmission, for the study of the discharges in vacuum tubes, the wireless energy transmission, for the production of the cathode rays, that is x-rays and other experiments. Aiming to transfer the signals and the energy to any point of the surface of the Earth, in the late of 19th century, he had discovered and later patented a new type of high frequency generator called a magnifying transmitter. He used it to examine the propagation of electromagnetic waves over the surface of the Earth in experiments in Colorado Springs in the period 1899-1900. Tesla observed the formation of standing electromagnetic waves on the surface of the Earth by measuring radiated electric field from distant lightning thunderstorm. He got the idea to generate the similar radiation to produce the standing waves. On the one hand, signal transmission, i.e. communication at great distances would be possible and on the other hand, with more powerful and with at least three magnifying transmitters the wireless transmission of energy without conductors at any point of the Earth surface could also be achieved. The discovery of the standing waves on the surface of the Earth and the invention of the magnifying transmitter he claimed his greatest inventions. Less than two years later, at the end of 1901, he designed and started to build a much stronger magnifying transmitter on Long Island near New York City (the Wardenclyffe tower wishing to become a world telecommunication center. During the tower construction, he elaborated the plans for an even stronger transmitter based on

  19. The importance of a multidisciplinary approach in the treatment of mutilating electrical injury: a case study.

    Science.gov (United States)

    Lipový, B; Rihová, H; Kaloudová, Y; Suchánek, I; Gregorová, N; Hokynková, A; Jelínková, Z; Agalarev, V

    2010-01-01

    Electrical burns are not ranked among the most frequent type of injuries, but they have the most devastating potential of all thermal injuries and often cause lifelong stigmatization. Those primarily affected are young males: work injuries predominate. An electrical burn is a specific nosological unit that has multiple acute and chronic abnormal manifestations. In this study we describe the case of a young man who suffered an electrical injury after contact with a high-voltage line (22,000 volts) while paragliding. This contact was followed by a 10 m fall. In our work we present the need for multidisciplinary cooperation along with the opportunities, problems and risks that accompany the treatment of this type of injury.

  20. A Four-Phase High Voltage Conversion Ratio Bidirectional DC-DC Converter for Battery Applications

    Directory of Open Access Journals (Sweden)

    Li-Kun Xue

    2015-06-01

    Full Text Available This study presents a four-phase interleaved high voltage conversion ratio bidirectional DC-DC converter circuit based on coupled inductors and switched capacitors, which can eliminate the defects of conventional high voltage conversion ratio bidirectional DC-DC converters in terms of high-voltage/current stress, less efficiency and low-power limitation. Parallel channels are used to reduce current stress at the low-voltage side and series connected switched capacitors are used to enlarge voltage conversion ratio, reduce voltage stress and achieve auto current sharing. This paper proposes the operation principle, feature analysis and optimization design considerations. On this basis the objectives of high voltage conversion ratio, low voltage/current stress, high power density, high efficiency and high-power applications can be achieved. Some experimental results based on a 500 W prototype converter (24 V to 48 V at low-voltage side, 400 V at high-voltage side are given to verify the theoretical analysis and the effectiveness of the proposed converter.