WorldWideScience

Sample records for high-resolution gamma-spectrometry nepreryvnyj

  1. Laboratory of High resolution gamma spectrometry

    International Nuclear Information System (INIS)

    Mendez G, A.; Giber F, J.; Rivas C, I.; Reyes A, B.

    1992-01-01

    The Department of Nuclear Experimentation of the Nuclear Systems Management requests the collaboration of the Engineering unit for the supervision of the execution of the work of the High resolution Gamma spectrometry and low bottom laboratory, using the hut of the sub critic reactor of the Nuclear Center of Mexico. This laboratory has the purpose of determining the activity of special materials irradiated in nuclear power plants. In this report the architecture development, concepts, materials and diagrams for the realization of this type of work are presented. (Author)

  2. Laboratory of High resolution gamma spectrometry; Laboratorio de espectrometria gamma de alta resolucion

    Energy Technology Data Exchange (ETDEWEB)

    Mendez G, A.; Giber F, J.; Rivas C, I.; Reyes A, B

    1992-01-15

    The Department of Nuclear Experimentation of the Nuclear Systems Management requests the collaboration of the Engineering unit for the supervision of the execution of the work of the High resolution Gamma spectrometry and low bottom laboratory, using the hut of the sub critic reactor of the Nuclear Center of Mexico. This laboratory has the purpose of determining the activity of special materials irradiated in nuclear power plants. In this report the architecture development, concepts, materials and diagrams for the realization of this type of work are presented. (Author)

  3. Burn-Up Determination by High Resolution Gamma Spectrometry: Fission Product Migration Studies

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, R S; Blackadder, W H; Ronqvist, N

    1967-04-15

    The migration of solid fission products, in particular caesium and ruthenium, in high temperature oxide fuel can create a severe problem during the application of non-destructive burn-up methods employing gamma spectrometry, since caesium-137 is otherwise the most convenient long-lived burn-up monitor and ruthenium-106 can be used to distinguish between fissions in U-235 and Pu-239. As part of an experimental programme to develop burn-up methods, gamma scanning experiments have been performed on slices of irradiated UO{sub 2} pellets using a lithium-drifted germanium detector. The usefulness of the technique for migration studies has been demonstrated by comparing the fission product distribution curves across the specimen diameters with the microstructure of the specimens after polishing and etching.

  4. Use of a Shielded High Resolution Gamma Spectrometry System to Segregate LLW from Contact Handleable ILW Containing Plutonium - 13046

    Energy Technology Data Exchange (ETDEWEB)

    Lester, Rosemary; Wilkins, Colin [Canberra UK Ltd, Unit 1 B528.1, Harwell Science Campus, Oxfordshire OX11 0DF (United Kingdom); Chard, Patrick [Canberra UK Ltd, Forss Business and Technology park, Thurso, Caithness KW14 7UZ (United Kingdom); Jaederstroem, Henrik; LeBlanc, Paul; Mowry, Rick [Canberra Industries, Inc., 800 Research Parkway, Meriden, Connecticut, 06450 (United States); MacDonald, Sanders; Gunn, William [Dounreay Site Restoration Limited, Dounreay, Thurso, Caithness, KW14 7TZ (United Kingdom)

    2013-07-01

    Dounreay Site Restoration Limited (DSRL) have a number of drums of solid waste that may contain Plutonium Contaminated Material. These are currently categorised as Contact Handleable Intermediate Level Waste (CHILW). A significant fraction of these drums potentially contain waste that is in the Low Level Waste (LLW) category. A Canberra Q2 shielded high resolution gamma spectrometry system is being used to quantify the total activity of drums that are potentially in the LLW category in order to segregate those that do contain LLW from CHILW drums and thus to minimise the total volume of waste in the higher category. Am-241 is being used as an indicator of the presence of plutonium in the waste from its strong 59.54 keV gamma-ray; a knowledge of the different waste streams from which the material originates allows a pessimistic waste 'fingerprint' to be used in order to determine an upper limit to the activities of the weak and non-gamma-emitting plutonium and associated radionuclides. This paper describes the main features of the high resolution gamma spectrometry system being used by DSRL to perform the segregation of CHILW and LLW and how it was configured and calibrated using the Canberra In-Situ Object Counting System (ISOCS). It also describes how potential LLW drums are selected for assay and how the system uses the existing waste stream fingerprint information to determine a reliable upper limit for the total activity present in each measured drum. Results from the initial on-site commissioning trials and the first measurements of waste drums using the new monitor are presented. (authors)

  5. Cooperation on Improved Isotopic Identification and Analysis Software for Portable, Electrically Cooled High-Resolution Gamma Spectrometry Systems Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Dreyer, Jonathan G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wang, Tzu-Fang [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Vo, Duc T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Funk, Pierre F. [Inst. for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses (France); Weber, Anne-Laure [Inst. for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses (France)

    2017-07-20

    Under a 2006 agreement between the Department of Energy (DOE) of the United States of America and the Institut de Radioprotection et de Sûreté Nucléaire (IRSN) of France, the National Nuclear Security Administration (NNSA) within DOE and IRSN initiated a collaboration to improve isotopic identification and analysis of nuclear material [i.e., plutonium (Pu) and uranium (U)]. The specific aim of the collaborative project was to develop new versions of two types of isotopic identification and analysis software: (1) the fixed-energy response-function analysis for multiple energies (FRAM) codes and (2) multi-group analysis (MGA) codes. The project is entitled Action Sheet 4 – Cooperation on Improved Isotopic Identification and Analysis Software for Portable, Electrically Cooled, High-Resolution Gamma Spectrometry Systems (Action Sheet 4). FRAM and MGA/U235HI are software codes used to analyze isotopic ratios of U and Pu. FRAM is an application that uses parameter sets for the analysis of U or Pu. MGA and U235HI are two separate applications that analyze Pu or U, respectively. They have traditionally been used by safeguards practitioners to analyze gamma spectra acquired with high-resolution gamma spectrometry (HRGS) systems that are cooled by liquid nitrogen. However, it was discovered that these analysis programs were not as accurate when used on spectra acquired with a newer generation of more portable, electrically cooled HRGS (ECHRGS) systems. In response to this need, DOE/NNSA and IRSN collaborated to update the FRAM and U235HI codes to improve their performance with newer ECHRGS systems. Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL) performed this work for DOE/NNSA.

  6. Determination of Pu isotopic composition and 241Am by high resolution gamma spectrometry on solid samples

    International Nuclear Information System (INIS)

    Sarkar, Arnab; Paul, Sumana; Aggarwal, Suresh K.; Tomar, Bhupendra S.

    2011-08-01

    The present report gives a detailed account of the development of non-destructive assay technique using high resolution gamma-ray spectrometry (HRGS) for determination of plutonium (Pu) isotopic composition and the 241 Am content in solid Pu samples. Energy range 120-420 keV was used in this study. The methodology involves in situ relative efficiency calibration during the measurement process itself, to reduce the errors and increase the reliability of the method. Twenty solid Pu samples of power reactor and research reactor grade were analyzed by this method and the results were compared with those obtained by thermal ionization mass spectrometry. The accuracy of the final results depends strongly upon the accuracy of the available nuclear data (decay constant, gamma abundance etc.). MATLAB based programme was written to perform the analysis. A counting time of 4 hour was chosen for achieving good statistics on the results for samples having 100-200 mg of Pu. The attainable accuracy is found to be 0.5-1% for the fissile isotopes ( 239 Pu + 241 Pu) and 5-10% for 241 Am content. (author)

  7. Advanced Collimators for Verification of the Pu Isotopic Composition in Fresh Fuel by High Resolution Gamma Spectrometry

    International Nuclear Information System (INIS)

    Lebrun, Alain; Berlizov, Andriy

    2013-06-01

    IAEA verification of the nuclear material contained in fresh nuclear fuel assemblies is usually based on neutron coincidence counting (NCC). In the case of uranium fuel, active NCC provides the total content of uranium-235 per unit of length which, combined with active length verification, fully supports the verification. In the case of plutonium fuel, passive NCC provides the plutonium-240 equivalent content which needs to be associated with a measurement of the isotopic composition and active length measurement to complete the verification. Plutonium isotopic composition is verified by high resolution gamma spectrometry (HRGS) applied on fresh fuel assemblies assuming all fuel rods are fabricated from the same plutonium batch. For particular verifications when such an assumption cannot be reasonably made, there is a need to optimize the HRGS measurement so that contributions of internal rods to the recorded spectrum are maximized, thus providing equally strong verification of the internal fuel rods. This paper reports on simulation work carried out to design special collimators aimed at reducing the relative contribution of external fuel rods while enhancing the signal recorded from internal rods. Both cases of square lattices (e.g. 17x17 pressurized water reactor (PWR) fuel) and hexagonal compact lattices (e.g. BN800 fast neutron reactor (FNR) fuel) have been addressed. In the case of PWR lattices, the relatively large optical path to internal pins compensates for low plutonium concentrations and the large size of the fuel assemblies. A special collimator based on multiple, asymmetrical, vertical slots allows recording a spectrum from internal rods only when needed. In the FNR case, the triangular lattice is much more compact and the optical path to internal rods is very narrow. However, higher plutonium concentration and use of high energy ranges allow the verification of internal rods to be significantly strengthened. Encouraging results from the simulation

  8. Nuclear energy - Waste-packages activity measurement - Part.1: high-resolution gamma spectrometry in integral mode with open geometry

    International Nuclear Information System (INIS)

    2004-01-01

    ISO 14850:2004 describes a procedure for measurements of gamma-emitting radionuclide activity in homogeneous objects such as unconditioned waste (including process waste, dismantling waste, etc.), waste conditioned in various matrices (bitumen, hydraulic binder, thermosetting resins, etc.), notably in the form of 100 L, 200 L, 400 L or 800 L drums, and test specimens or samples, (vitrified waste), and waste packaged in a container, notably technological waste. It also specifies the calibration of the gamma spectrometry chain. The gamma energies used generally range from 0,05 MeV to 3 MeV. (authors)

  9. Determination of the detection limit and decision threshold for ionizing radiation measurements. Part 3: Fundamentals and application to counting measurements by high resolution gamma spectrometry, without the influence of sample treatment

    International Nuclear Information System (INIS)

    2000-01-01

    This part of ISO 11929 addresses the field of ionizing radiation measurements in which events (in particular pulses) are counted by high resolution gamma spectrometry registrating a pulse-heights distribution (acquisition of a multichannel spectrum), for example on samples. It considers exclusively the random character of radioactive decay and of pulse counting and ignores all other influences (e.g. arising from sample treatment, weighing, enrichment or the instability of the test setup). It assumes that the distance of neighbouring peaks of gamma lines is not smaller than four times the full width half maximum (FWHM) of gamma line and that the background near to gamma line is nearly a straight line. Otherwise ISO 11929-1 or ISO 11929-2 should be used. ISO 11929 consists of the following parts, under the general title Determination of the detection limit and decision threshold for ionizing radiation measurements: Part 1: Fundamentals and application to counting measurements without the influence of sample treatment; Part 2: Fundamentals and application to counting measurements with the influence of sample treatment; Part 3: Fundamentals and application to counting measurements by high resolution gamma spectrometry, without the influence of sample treatment; Part 4: Fundamentals and application to measurements by use of linear scale analogue ratemeters, without the influence of sample treatment. This part of ISO 11929 was prepared in parallel with other International Standards prepared by WG2 (now WG 17): ISO 11932:1996, Activity measurements of solid materials considered for recycling, re-use or disposal as nonradioactive waste, and ISO 11929-1, ISO 11929-2 and ISO 11929-4, and is, consequently, complementary to these documents

  10. Reactor gamma spectrometry: status

    International Nuclear Information System (INIS)

    Gold, R.; Kaiser, B.J.

    1979-01-01

    Current work is described for Compton Recoil Gamma-Ray Spectrometry including developments in experimental technique as well as recent reactor spectrometry measurements. The current status of the method is described concerning gamma spectromoetry probe design and response characteristics. Emphasis is given to gamma spectrometry work in US LWR and BR programs. Gamma spectrometry in BR environments are outlined by focussing on start-up plans for the Fast Test Reactor (FTR). Gamma spectrometry results are presented for a LWR pressure vessel mockup in the Poolside Critical Assembly (PCA) at Oak Ridge National Laboratory

  11. Automatic gamma spectrometry analytical apparatus

    International Nuclear Information System (INIS)

    Lamargot, J.-P.; Wanin, Maurice.

    1980-01-01

    This invention falls within the area of quantitative or semi-quantitative analysis by gamma spectrometry and particularly refers to a device for bringing the samples into the counting position. The purpose of this invention is precisely to provide an automatic apparatus specifically adapted to the analysis of hard gamma radiations. To this effect, the invention relates to a gamma spectrometry analytical device comprising a lead containment, a detector of which the sensitive part is located inside the containment and additionally comprising a transfer system for bringing the analyzed samples in succession to a counting position inside the containment above the detector. A feed compartment enables the samples to be brought in turn one by one on to the transfer system through a duct connecting the compartment to the transfer system. Sequential systems for the coordinated forward feed of the samples in the compartment and the transfer system complete this device [fr

  12. Urban gamma spectrometry. Report 2

    Energy Technology Data Exchange (ETDEWEB)

    Aage, H.K. (Technical Univ. of Denmark, Kgs. Lyngby (Denmark)); Kuukankorpi, S.; Moring, M.; Smolander, P.; Toivonen, H. (Radiation and Nuclear Safety Authority, Helsinki (Finland))

    2009-06-15

    Urban gamma spectrometry has been given only minor attention with the focus being on rural gamma spectrometry. However, in recent years the Nordic emergency management authorities have turned focus towards border control and lost or stolen sources. Gamma spectra measured in urban areas are characterized by a wide variety of spectrum shapes and very fast changes in environmental background. In 2004 a Danish CGS (Carborne Gamma Spectrometry) survey took place in Copenhagen. It was found that gamma spectrometry in urban areas is far more complicated to interpret than had previously been thought and a new method 'Fitting with Spectral Components', FSC, based on NASVD, was tested with some success. In Finland, a database 'LINSSI' has been developed for spectral data management. In CGS search mode a 'peak hypothesis test' is applied to the measured spectra. This system was tested during the Helsinki 2005 Athletics World Championship and it provides fast and reliable automated alarms for intermediate and high level signals. In Sweden mobile detector systems are used for border controls and problems are encountered when making measurement in harbour, container areas. The methods for handling data and for interpretation of urban gamma spectrometry measurements were compared and tested on the same data sets from Copenhagen and Helsinki. Software tools were developed for converting data between the Finnish LINSSI database and the binary file formats used in Denmark and Sweden. The Processing methods used at DTU and STUK have different goals. The ASSS and FSC methods are designed to optimize the overall detection capability of the system, while sacrificing speed, usability and to a certain level robustness. These methods cannot always be used for real time analysis. The Peak Significance method is designed to give robust alarms in real time, while sacrificing some of the detection capability. Thus these methods are not interchangeable, but rather

  13. Urban gamma spectrometry. Report 2

    International Nuclear Information System (INIS)

    Aage, H.K.; Kuukankorpi, S.; Moring, M.; Smolander, P.; Toivonen, H.

    2009-06-01

    Urban gamma spectrometry has been given only minor attention with the focus being on rural gamma spectrometry. However, in recent years the Nordic emergency management authorities have turned focus towards border control and lost or stolen sources. Gamma spectra measured in urban areas are characterized by a wide variety of spectrum shapes and very fast changes in environmental background. In 2004 a Danish CGS (Carborne Gamma Spectrometry) survey took place in Copenhagen. It was found that gamma spectrometry in urban areas is far more complicated to interpret than had previously been thought and a new method 'Fitting with Spectral Components', FSC, based on NASVD, was tested with some success. In Finland, a database 'LINSSI' has been developed for spectral data management. In CGS search mode a 'peak hypothesis test' is applied to the measured spectra. This system was tested during the Helsinki 2005 Athletics World Championship and it provides fast and reliable automated alarms for intermediate and high level signals. In Sweden mobile detector systems are used for border controls and problems are encountered when making measurement in harbour, container areas. The methods for handling data and for interpretation of urban gamma spectrometry measurements were compared and tested on the same data sets from Copenhagen and Helsinki. Software tools were developed for converting data between the Finnish LINSSI database and the binary file formats used in Denmark and Sweden. The Processing methods used at DTU and STUK have different goals. The ASSS and FSC methods are designed to optimize the overall detection capability of the system, while sacrificing speed, usability and to a certain level robustness. These methods cannot always be used for real time analysis. The Peak Significance method is designed to give robust alarms in real time, while sacrificing some of the detection capability. Thus these methods are not interchangeable, but rather complementary. An ideal system

  14. Calibration of the High Resolution Gamma Spectrometry Detection Systems from the Environmental Radioactivity Unit and Radiological Surveillance (ARU and RV); Calibracion de los Sistemas Detectores de Espectrometria Gamma de Alta Resolucion de la Unidad de Radiactividad Ambiental y Vigilancia Radiologica (URA y VR)

    Energy Technology Data Exchange (ETDEWEB)

    Suarez-Navarro, J. A.; Gasco, C.; Arana, M.; Suanez, A.

    2012-11-01

    In accordance with international regulations and with the quality criteria imposed by the internal quality system of the laboratory of gamma spectrometry, which belongs to the Unit of Environmental Radioactivity and Radiation Monitoring (URA y VR), it is necessary to perform a periodic calibration of the measurement systems of gamma spectrometry. The equipment calibration carries with the need for the preparation of the geometries of measurement and calibration in energy and in efficiencies. This report reflects the procedures for the preparation of the wide range of geometries available in the laboratory, as well as the different calibrations performed with those geometries in almost all the laboratory gamma detectors using the CANBERRA software Genie 2k. (Author) 9 refs.

  15. Determination of uranium and thorium using gamma spectrometry: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Olivares, D.M.M.; Koch, E.S.; Manso Guevara, M.V.; Garcia Velasco, F., E-mail: diango.mo87@gmail.com [Universidade Estadual de Santa Cruz (UNESC), Ilhéus, BA (Brazil)

    2017-07-01

    This paper presents the results of a pilot experiment aimed at standardizing procedures for the CPqCTR/UESC Gamma Spectrometry Laboratory (LEG) for the quantification of natural radioactive elements in solid environmental samples. The concentrations of {sup 238}U, {sup 232}Th and {sup 40}K in two sediment matrix belonging to the Caetité region were determined, by using the absolute method with uncertainties about 5%. The results were obtained using gamma spectrometry with a high-resolution p-type HPGe detector. As a closure, the absorbed dose, radium equivalent activity and the annual effective dose were calculated. (author)

  16. Determination of uranium and thorium using gamma spectrometry: a pilot study

    Science.gov (United States)

    Olivares, D. M. M.; Koch, E. S.; Guevara, M. V. M.; Velasco, F. G.

    2018-03-01

    This paper presents the results of a pilot experiment aimed at standardizing procedures for the CPqCTR/UESC Gamma Spectrometry Laboratory (LEG) for the quantification of natural radioactive elements in solid environmental samples. The concentrations of 238U, 232Th and 40K in two sediment matrix belonging to the Caetité region were determined, by using the absolute method with uncertainties about 5%. The results were obtained using gamma spectrometry with a high-resolution p-type HPGe detector. As a closure, the absorbed dose, radium equivalent activity and the annual effective dose were calculated.

  17. Nuclear energy. Waste-packages activity measurement. Part. 1: high-resolution gamma spectrometry in integral mode with open geometry; ISO 14850-1: 2004. Energie nucleaire -- Mesurage de l'activite de colis de dechets. Partie 1: Spectrometrie gamma haute resolution en mode integral et geometrie ouverte

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    ISO 14850:2004 describes a procedure for measurements of gamma-emitting radionuclide activity in homogeneous objects such as unconditioned waste (including process waste, dismantling waste, etc.), waste conditioned in various matrices (bitumen, hydraulic binder, thermosetting resins, etc.), notably in the form of 100 L, 200 L, 400 L or 800 L drums, and test specimens or samples, (vitrified waste), and waste packaged in a container, notably technological waste. It also specifies the calibration of the gamma spectrometry chain. The gamma energies used generally range from 0,05 MeV to 3 MeV.

  18. Nuclear energy - Waste-packages activity measurement - Part.1: high-resolution gamma spectrometry in integral mode with open geometry; ISO 14850-1:2004. Energie nucleaire - Mesurage de l'activite de colis de dechets - Partie 1: spectrometrie gamma haute resolution en mode integral et geometrie ouverte

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    ISO 14850:2004 describes a procedure for measurements of gamma-emitting radionuclide activity in homogeneous objects such as unconditioned waste (including process waste, dismantling waste, etc.), waste conditioned in various matrices (bitumen, hydraulic binder, thermosetting resins, etc.), notably in the form of 100 L, 200 L, 400 L or 800 L drums, and test specimens or samples, (vitrified waste), and waste packaged in a container, notably technological waste. It also specifies the calibration of the gamma spectrometry chain. The gamma energies used generally range from 0,05 MeV to 3 MeV. (authors)

  19. Urban gamma spectrometry. Report 1

    International Nuclear Information System (INIS)

    Aage, H.K.; Kuukankorpi, S.; Moring, M.; Smolander, P.; Toivonen, H.

    2009-06-01

    This report contains the present status and results for the NKS UGS-project per 1 June 2006 for NKS partners DTU, Denmark, and STUK, Finland. The Danish and Finnish CGS (Carborne Gamma Spectrometry) systems are not of similar types. The Danish CGS system(s) only make use of one NaI(Tl) detector whereas the Finnish CGS system consists of several detectors, NaI(Tl) and HPGe both and as an additional feature the Finnish detectors have position dependent different fields of view. Furthermore, the Finnish system is equipped with an air sampling system. In terms of operation, the Danish detector is located on the rooftop where as the Finnish detectors are located inside the vehicle. The Finnish and the Danish team use different methods for data processing. STUK uses a hypothesis test method to get robust real time alarms (within 10 seconds) when significant peaks from a previously defined set of nuclides are detected. An alarm for a significantly elevated total pulse rate is sent if none of the predefined nuclides is identified. All data are stored to the LINSSI database, which facilitates easy data retrieval for post processing. DEMA/DTU bases their calculations on full spectrum fitting using NASVD and the Danish software NucSpec. Source signals are found from spectrum fitting residuals or from stripping of energy windows - either by the standard 4-windows method or by a measurement based method where stripping factors for any window of interest can be derived from the measurements themselves. A thorough description of the two systems and data processing methods (including mathematics) are described in this report. For the Danish methods of data processing some comparisons have been made, but no final conclusion has been reached yet. Raw urban data has been investigated along with urban data sets to which source signals have been added and searched for. For the Finnish method calibration plots of the minimum detection limits for two different detector types have been

  20. Urban gamma spectrometry. Report 1

    Energy Technology Data Exchange (ETDEWEB)

    Aage, H K [Technical Univ. of Denmark, Kgs. Lyngby (Denmark); Kuukankorpi, S; Moring, M; Smolander, P; Toivonen, H [Radiation and Nuclear Safety Authority, Helsinki (Finland)

    2009-06-15

    This report contains the present status and results for the NKS UGS-project per 1 June 2006 for NKS partners DTU, Denmark, and STUK, Finland. The Danish and Finnish CGS (Carborne Gamma Spectrometry) systems are not of similar types. The Danish CGS system(s) only make use of one NaI(Tl) detector whereas the Finnish CGS system consists of several detectors, NaI(Tl) and HPGe both and as an additional feature the Finnish detectors have position dependent different fields of view. Furthermore, the Finnish system is equipped with an air sampling system. In terms of operation, the Danish detector is located on the rooftop where as the Finnish detectors are located inside the vehicle. The Finnish and the Danish team use different methods for data processing. STUK uses a hypothesis test method to get robust real time alarms (within 10 seconds) when significant peaks from a previously defined set of nuclides are detected. An alarm for a significantly elevated total pulse rate is sent if none of the predefined nuclides is identified. All data are stored to the LINSSI database, which facilitates easy data retrieval for post processing. DEMA/DTU bases their calculations on full spectrum fitting using NASVD and the Danish software NucSpec. Source signals are found from spectrum fitting residuals or from stripping of energy windows - either by the standard 4-windows method or by a measurement based method where stripping factors for any window of interest can be derived from the measurements themselves. A thorough description of the two systems and data processing methods (including mathematics) are described in this report. For the Danish methods of data processing some comparisons have been made, but no final conclusion has been reached yet. Raw urban data has been investigated along with urban data sets to which source signals have been added and searched for. For the Finnish method calibration plots of the minimum detection limits for two different detector types have been

  1. An automatic sample changer for gamma spectrometry

    International Nuclear Information System (INIS)

    Andrews, D.J.

    1984-01-01

    An automatic sample changer for gamma spectrometry is described which is designed for large-volume, low radioactivity environmental samples of various sizes up to maximum dimensions 100 mm diameter x 60 mm high. The sample changer is suitable for use with most existing gamma spectrometry systems which utilize GeLi or NaI detectors in vertical mode, in conjunction with a pulse height analyzer having auto-cycle and suitable data output facilities; it is linked to a Nuclear Data ND 6620 computer-based analysis system. (U.K.)

  2. Application of gamma spectrometry survey and discussion on data processing

    International Nuclear Information System (INIS)

    Li Ji'an; He Jianguo

    2008-01-01

    This paper analyzed and discussed the different opinions about the measured parameters of gamma spectrometry data, introduced the effect of gamma spectrometry survey to the search for sandstone type uranium deposit. The author believes that it is very necessary to perform some ground gamma spectrometry survey and enforce the development and application of airborne radiometric data so as to carry out the role of gamma spectrometry in the exploration of sandstone type uranium deposit. (authors)

  3. Performance of gamma spectrometry counting system

    International Nuclear Information System (INIS)

    Yii Mei Wo; Maziah Mahmud

    2007-01-01

    Gamma spectrometry counting system widely used as tool to measure qualitative and quantitative gamma-ray emitters in a sample. Container size, sample to detector distance, sample volume are well known factors that affecting the quality of measurement. However, factor such as the age of the system was not been reported. Therefore, the objective of this study is to find out how the age factor affecting the quality of the measurement. From this study, it is found that when the age of the system increased, the system tends to have higher lower limit of detection and poorer linearity showing that age factor do affecting the quality of measurement. (Author)

  4. In situ gamma spectrometry development for site mapping

    International Nuclear Information System (INIS)

    Panza, F.

    2012-01-01

    The high-resolution gamma spectrometry currently provides a powerful analytical tool for performing environmental measurements. In the context of radiological characterization of a site (natural or artificial radioactivity) and for the dismantling of nuclear installations, mapping of radionuclides is an important asset. The idea is to move a HPGe spectrometer to study the site and from nuclear and position data, to identify, to locate and to quantify the radionuclides present in the soil. The development of this tool follows an intercomparison (ISIS 2007) where an intervention/crisis exercise showed the limits of current tools. The main part of this research project has focused on mapping of nuclear data. Knowledge of the parameters of an in situ spectrum helped to create a simulator, modeling the response of a spectrometer moving over contaminated soil. The simulator itself helped to develop algorithms for mapping and to test them in extreme situations and not realizable. A large part of this research leads to the creation of a viable prototype providing real-time information concerning the identity and locality as possible radionuclides. The work performed on the deconvolution of data can make in post processing a map of the activity of radionuclide soil but also an indication of the depth distribution of the source. The prototype named OSCAR was tested on contaminated sites (Switzerland and Japan) and the results are in agreement with reference measurements. (author)

  5. Natural radioactivity in iron and steel materials by low-level gamma spectrometry

    International Nuclear Information System (INIS)

    Tanase, G.; Tanase, Maria

    2003-01-01

    High resolution low-level gamma spectrometry was applied to perform a radioactivity measurement in iron and steel raw materials (coal, coke, iron ore, pellets, manganese ore, limestone, dolomite), auxiliary materials (scorialite, oxide of Ti, bentonite), and some related final products (cast iron, slag, blast-furnace, flue dust) involved in iron making processing. We control the activity of materials in various kinds of samples and we investigate for transfer of radioactivity during the blast-furnace process. Artificial radioisotopes are rarely encountered. (authors)

  6. Characterization of Uranium-Bearing Material by Passive Non-Destructive Gamma Spectrometry

    International Nuclear Information System (INIS)

    Lakosi, L.; Zsigrai, J.; Nguyen, C.T.

    2009-01-01

    Characterization of nuclear materials is equally important in nuclear safeguards (inventory verification) and in nuclear security (revealing illicit trafficking). Analysis of materials is a key issue in both fields. Natural (NU), depleted (DU), low-enriched (LEU), and high-enriched uranium (HEU) samples were analysed by high resolution gamma spectrometry (HRGS). Isotopic composition and total U-content of reactor fuel pellets and powder were determined. A unique HRGS method was developed for the first time for determining the production date of the material of unknown origin. Identifying reprocessed uranium proved to be possible by HRGS as well.

  7. Composite mapping experiences in airborne gamma spectrometry

    International Nuclear Information System (INIS)

    Bucher, B.

    2014-01-01

    During an international intercomparison exercise of airborne gamma spectrometry held in Switzerland 2007 teams from Germany, France and Switzerland were proving their capabilities. One of the tasks was the composite mapping of an area around Basel. Each team was mainly covering the part of its own country at its own flying procedures. They delivered the evaluated data in a data format agreed in advance. The quantities to be delivered were also defined in advance. Nevertheless, during the process to put the data together a few questions raised: Which dose rate was meant? Had the dose rate to be delivered with or without cosmic contribution? Activity per dry or wet mass? Which coordinate system was used? Finally, the data could be put together in one map. For working procedures in case of an emergency, quantities of interest and exchange data format have to be defined in advance. But the procedures have also to be proved regularly. (author)

  8. Composite mapping experiences in airborne gamma spectrometry.

    Science.gov (United States)

    Bucher, B

    2014-08-01

    During an international intercomparison exercise of airborne gamma spectrometry held in Switzerland 2007 teams from Germany, France and Switzerland were proving their capabilities. One of the tasks was the composite mapping of an area around Basel. Each team was mainly covering the part of its own country at its own flying procedures. They delivered the evaluated data in a data format agreed in advance. The quantities to be delivered were also defined in advance. Nevertheless, during the process to put the data together a few questions raised: Which dose rate was meant? Had the dose rate to be delivered with or without cosmic contribution? Activity per dry or wet mass? Which coordinate system was used? Finally, the data could be put together in one map. For working procedures in case of an emergency, quantities of interest and exchange data format have to be defined in advance. But the procedures have also to be proved regularly. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Measurement of natural radioactivity: Calibration and performance of a high-resolution gamma spectrometry facility

    DEFF Research Database (Denmark)

    Murray, A. S.; Helsted, L. M.; Autzen, M.

    2018-01-01

    Murray et al. (2015) described an international inter-comparison of dose rate measurements undertaken using a homogenised beach ridge sand from Jutland, Denmark. The measured concentrations for 226Ra, 232Th and 40K from different laboratories varied considerably, with relative standard deviations...... of 26% (n=8), 59% (n=23) and 15% (n=23), respectively. In contrast, the relative standard deviations observed internally within our laboratory were 9%, 11% and 7%, respectively (n=20), and in addition our mean values were consistent with the global 40K mean, but significantly different from the 232Th...... mean. These problems in both accuracy and precision have led us to examine both the long term performance of our analytical facility, and its calibration. Our approach to the preparation of new absolute 238U, 232Th and 40K standards is outlined and tested against international standards. We also report...

  10. Burn-Up Determination by High Resolution Gamma Spectrometry: Axial and Diametral Scanning Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, R S; Blackadder, W H; Ronqvist, N

    1967-02-15

    In the gamma spectrometric determination of burn-up the use of a single fission product as a monitor of the specimen fission rate is subject to errors caused by activity saturation or, in certain cases, fission product migration. Results are presented of experiments in which all the resolvable gamma peaks in the fission product spectrum have been used to calculate the fission rate; these results form a pattern which reflect errors in the literature values of the gamma branching ratios, fission yields etc., and also represent a series of empirical correction factors. Axial and diametral scanning experiments on a long-irradiated low-enrichment fuel element are also described and demonstrate that it is possible to differentiate between fissions in U-235 and in Pu-239 respectively by means of the ratios of the Ru-106 activity to the activities of the other fission products.

  11. High resolution gamma spectrometry of size-separated soils from high background areas of Kerala

    International Nuclear Information System (INIS)

    Menon, M.R.; Sadasivan, S.; Nambi, K.S.V.

    1992-01-01

    Soil samples from a high background area of Kerala were analysed for their natural radionuclide content and distribution with particle size. The samples exhibited inhomogeneity in activity distribution. The smaller size particles had higher activity. The open air dose estimates are also presented. (author). 5 refs., 2 tabs

  12. Neutron activation analysis of high purity silver using high resolution gamma-spectrometry

    International Nuclear Information System (INIS)

    Gilbert, E.N.; Veriovkin, G.V.; Botchkaryov, B.N.; Godovikov, A.A.; Zhavoronkov, V.Ya.; Mikhailov, V.A.

    1975-01-01

    A method of neutron activation determination of microimpurities in high purity silver has been developed. For matrix activity separation the extraction of silver by dibuthylsulfide /DBS/ was employed. The purification coefficient was 10 8 after triple extraction. To study the behaviour of microimpurities in the extraction procedure and to determine their chemical yields some tracer experiments were undertaken with radionuclides of Na, Se, Fe, Co, Cu, As, Sc, Te, Zr, Hf, Mo, W, Cd, In, Sb, La, Ce, Eu, Ta, Re, Ir, Ru. All the elements studied were found to remain in the aqueous phase up to 96-99% after triple extraction with DBS. To estimate the accuracy of the method and to study the mutual influence of the elements in the sample in various relative amounts on the accuracy of the analysis, a number of experiments of ''added-found'' type was performed and the results were treated statistically. In these experiments model mixtures of 30 nuclides were analysed after triple DBS extraction. The t-criterion values for the confidence interval at P=0.95 show the absence of systematic errors. Variation coefficient values do not exceed 15%. Using Ge/Li/ detector it was possible to determine 30 elements simultaneously in silver samples. (T.G.)

  13. Gamma spectrometry for chronology of recent sediments

    International Nuclear Information System (INIS)

    Pittauerova, Daniela

    2013-01-01

    This thesis deals with several aspects of gamma spectrometric analysis of natural and artificial isotopes in sediments and their use as tracers for qualification and quantification of accumulation and mixing processes in different aquatic environments. Sediment cores from three distinct areas including terrigenous sediments deposited on the continental slope off NW Africa, deep sea sediments off Sumba Island and five stations from the Gulf of Eilat in the Red Sea area were measured and interpreted within this dissertation. The main concern in gamma spectrometry of voluminous environmental samples is a reliable efficiency calibration. This is specially relevant for the analysis of low energy gamma emitters (<100 keV). 210 Pb, an important isotopic tracer to cover the period of the last century, is one of them. Within this work mathematical efficiency calibration was applied using a commercial software package. A series of validation tests was performed and evaluated for point and voluminous samples. When using 210 Pb as a tracer it is necessary to determine its excess portion, which is not supported by ingrowth from the parent nuclide 226 Ra. Its analysis is mostly performed via short lived daughter isotopes that follow after the intermediate gaseous member 222 Rn. Preventing the escape of radon from the sample is a critical step before analysis due to a negative effect of supported 210 Pb underestimation on the chronology, which was also documented in this thesis. Time series registering ingrowth of 214 Pb and 214 Bi towards radioactive equilibrium with 226 Ra in different containers were evaluated for analyses of 226 Ra. Direct analyses of 226 Ra was compared to its detection via daughter products. A method for aligning parallel radionuclide depth profiles was described and applied successfully in two case studies from the continental slope off NW Africa and off Sumba Island, Indonesia. This is primarily important when combined profiles obtained from short

  14. Gamma spectrometry for chronology of recent sediments

    Energy Technology Data Exchange (ETDEWEB)

    Pittauerova, Daniela

    2013-12-17

    This thesis deals with several aspects of gamma spectrometric analysis of natural and artificial isotopes in sediments and their use as tracers for qualification and quantification of accumulation and mixing processes in different aquatic environments. Sediment cores from three distinct areas including terrigenous sediments deposited on the continental slope off NW Africa, deep sea sediments off Sumba Island and five stations from the Gulf of Eilat in the Red Sea area were measured and interpreted within this dissertation. The main concern in gamma spectrometry of voluminous environmental samples is a reliable efficiency calibration. This is specially relevant for the analysis of low energy gamma emitters (<100 keV). {sup 210}Pb, an important isotopic tracer to cover the period of the last century, is one of them. Within this work mathematical efficiency calibration was applied using a commercial software package. A series of validation tests was performed and evaluated for point and voluminous samples. When using {sup 210}Pb as a tracer it is necessary to determine its excess portion, which is not supported by ingrowth from the parent nuclide {sup 226}Ra. Its analysis is mostly performed via short lived daughter isotopes that follow after the intermediate gaseous member {sup 222}Rn. Preventing the escape of radon from the sample is a critical step before analysis due to a negative effect of supported {sup 210}Pb underestimation on the chronology, which was also documented in this thesis. Time series registering ingrowth of {sup 214}Pb and {sup 214}Bi towards radioactive equilibrium with {sup 226}Ra in different containers were evaluated for analyses of {sup 226}Ra. Direct analyses of {sup 226}Ra was compared to its detection via daughter products. A method for aligning parallel radionuclide depth profiles was described and applied successfully in two case studies from the continental slope off NW Africa and off Sumba Island, Indonesia. This is primarily important

  15. The Utilization of Background Spectrum to Calibrate Gamma Spectrometry

    International Nuclear Information System (INIS)

    Mahrouka, M. M.; Mutawa, A. M.

    2004-01-01

    Many developed countries have very poor reference standards to calibrate their nuclear instrumentations or may find some difficulties to obtain a reference standard. In this work a simple way for Gamma spectrometry calibration was developed. The method depends on one reference point and additional points from the background. The two derived equations were applied to the analyses of radioactive nuclides in soil and liquid samples prepared by IAEA laboratories through AL MERA Project. The results showed the precision of the methodology used, as well as, the possibility of using some points in the background spectrum as a replacement for reference standards of Gamma spectrometry calibration. (authors)

  16. Methodology for determination of activity of radionuclides by gamma spectrometry

    International Nuclear Information System (INIS)

    Fragoso, Maria da Conceicao de Farias; Oliveira, Victor Rogerio S. de; Oliveira, Mercia L.; Lima, Fernando Roberto de Andrade

    2014-01-01

    Due to the growth in the number of procedures that make use of the positron emission tomography (PET), there is a need for standard solutions for the calibration of the systems used for the measurement of the PET radiopharmaceutical (activimeter) in radiopharmacies and in nuclear medicine services. Among the existing alternatives for the standardization of radioactive sources, the method known as gamma spectrometry is widely used for short-lived radionuclides. The purpose of this study was to implement the methodology for standardization of the 18 F solutions by gamma spectrometry at the Regional Center for Nuclear Sciences of the Northeast (CRCN-NE/CNEN-NE), Brazil. (author)

  17. Evaluation of gamma-spectrometry equipment for on-site inspection

    International Nuclear Information System (INIS)

    Burnett, J.L.; Milbrath, B.D.; Mueller, W.F.

    2017-01-01

    An On-site Inspection (OSI) is an important component of the verification regime of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), with the objective of gathering evidence of a possible Treaty violation. This includes the use of gamma-spectrometry equipment to identify 17 particulate radionuclides that are indicative of a nuclear explosion. This research provides an evaluation of high- (germanium), medium- (cadmium zinc telluride) and low-resolution (sodium iodide and lanthanum bromide) detectors using modelled radionuclide signatures from a nuclear explosion and Monte Carlo simulations of a detector response. The complex radionuclide signatures are shown to only be distinguishable using a high-resolution system for 1 week and 1 year post-detonation cases. (author)

  18. Determination of uranium-235 by differential gamma spectrometry

    International Nuclear Information System (INIS)

    Suner, A.A.; La Gamma de Batistoni, A.M.G.; Botbol, J.

    1974-12-01

    A method for the determination of U-235 contained in solutions of uranium, by gamma spectrometry with Ge(Li) detector is described. Ra-226 is coprecipitated in BaSO 4 . The activity at 186 keV is measured, substracted by the corresponding of a standard. The detection limit is 1% of increment of U-235 over the standard. (author)

  19. The determination and use of radionuclide background in gamma spectrometry

    International Nuclear Information System (INIS)

    Zimmer, W.H.

    1986-01-01

    Background is the major component of gross photon peak area. Therefore, net area, nuclide activity, counting uncertainty, and limits of detection calculations are no better than the calculation of background. In this study, background in gamma spectrometry is explored in several of its aspects. Means are presented to reduce background. Standard practices are presented to be used in the acquisition of valid, relevant background data. Unified standard calculations with examples are presented in the use of background data to determine net count and counting uncertainty. L. A. Currie's latest calculations of Lower Limits of Detection (1) (LLD) as they apply to gamma spectrometry are reviewed. Finally, Maximum Undetected Activity (MUA), LLD, and Critical Level (CL) concepts and calculations are compared in sample spectra

  20. Collection and preparation of samples for gamma spectrometry

    International Nuclear Information System (INIS)

    Pan Jingquan

    1994-01-01

    The paper presents the basic principles of sample collection and preparation: setting up unified sampling program, methods and procedures, sample packing, transportation and storage, determination of sample quantity, sample pretreatment and preparation of samples to be analysed, etc. for gamma spectrometry. And the paper also describes briefly the main methods and special issues of sampling and preparation for the same environmental and biological samples, such as, air, water, grass, soil and foods

  1. Gamma spectrometry analysis of fertilizers used in Costa Rica

    International Nuclear Information System (INIS)

    Loria, L.G.; Jimenez, R.; Badilla, M.

    2002-01-01

    Using the low level gamma spectrometry technique, the specific activity of natural and artificial isotopes present in national consumption fertilizers, supplied by local dealers, was quantified. The most outstanding isotope found in some of the fertilizers is U 235 , with an specific activity higher than the expected in this kind of product, which might mean that this isotope comes from imported raw material. (Author) [es

  2. Design and fabrication of shielding for gamma spectrometry

    International Nuclear Information System (INIS)

    Mariano H, E.

    1991-05-01

    To have a system of gamma spectrometry in the Radiological Mobile Unit No. 1 (UMOR-1) was designed and manufactured an armor-plating appropriate to this, to make analysis of radioactive samples in place in the event of a radiological emergency, besides being able to give support to the Management of Radiological Safety, and even to give service of sample analysis of other Institutions. (Author)

  3. In-pile gamma spectrometry and irradiation control at Osiris

    International Nuclear Information System (INIS)

    Farny, G.; Destot, M.; Corre, J.; Texier, D.; Faugere, J.L.; Mouchnino, M.

    1975-01-01

    A new gamma spectrometry facility is available near Osiris reactor core, at Saclay. This device enables nuclear fuels to be examined in loops or capsules all along their irradiation, a few minutes being sufficient to transfer the fuel from the irradiation place to the measurement bench. So, spacelike and timelike history of a lot of fission products, especially short-lived radionuclides, can be observed. Using such in-pile spectrometry device, of original design, allows to avoid radioactive decay corrections and the risks of any information less. Performance of the device is given together with some preliminary results and their interpretation [fr

  4. High Resolution Elevation Contours

    Data.gov (United States)

    Minnesota Department of Natural Resources — This dataset contains contours generated from high resolution data sources such as LiDAR. Generally speaking this data is 2 foot or less contour interval.

  5. Use of gamma spectrometry for analysis of three reference materials

    International Nuclear Information System (INIS)

    Kinova, L.

    2004-01-01

    All reference materials (Reference material A: weight = 49.23 g; Reference material B: weight = 36.08 g; Reference material C: weight = 26.18 g) were packed in 50 cm 3 polypropylene vials, sealed and measured consecutively three times at intervals of the average of 25 days. Low background gamma spectrometry system: HPGe detector with high energy resolution (FWHM for 1332 KeV of Co-60 is 1.9 KeV, Relative counting efficiency for the same energy is 21 %) was used. Results: All materials are of low activity and must be measured for a long time.The highest specific activity of a man-made radionuclides Cs-137 and Am-241 is in the material A. An instrumentally measurable activity of Pb-210 also can be observed in this material. Medium values are in the material B. The reference material C according to the specific activity seems to be a low natural radioactivity material with highest activity of natural nuclides Th-232 and Pa-234 (progeny of U-238). Conclusions: Gamma spectrometry is an useful tool for initial measurement of materials with low radioactivity. Such measurements give an orientation for the nuclides content and approximate activity in the material for the following radiochemical determinations

  6. Detection of 210Pb in the lungs of smokers by in-vivo gamma spectrometry

    International Nuclear Information System (INIS)

    Berger, C.D.; Lane, B.H.

    1982-09-01

    Since mainstream smoke is highly enriched in 210 Pb, alpha radiation from inhaled cigarette smoke particles has been proposed as a cancer-producing agent in cigarette smokers. 210 Po and 210 Pb have been observed in tobacco, cigarette smoke and in the lungs of smokers. Since 210 Pb is highly enriched in mainstream smoke, there have been estimates of yearly excesses of 210 Pb in the lungs of one-pack-a-day smokers of 3 to 10 pCi (0.11 to 0.37 Bq). The ORNL Whole Body Counter was used to verify this estimate by the methodology of high-resolution, in vivo gamma spectrometry. Measurements were made on 113 adult male non-radiation workers who have either smoked at least one pack of cigarettes per day for at least five years, or have never smoked cigarettes. An analysis-of-variance table was generated based on the Pb-ratio for each individual which revealed that there was no statistically significant increase in the amount of 210 Pb in the lungs of smokers over those of non-smokers. Sources of error are also discussed

  7. Cosmic veto gamma-spectrometry for Comprehensive Nuclear-Test-Ban Treaty samples

    International Nuclear Information System (INIS)

    Burnett, J.L.; Davies, A.V.

    2014-01-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a global network of monitoring stations that perform high-resolution gamma-spectrometry on air filter samples for the identification of 85 radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a novel cosmic veto gamma-spectrometer has been developed to improve the sensitivity of station measurements, providing a mean background reduction of 80.8% with mean MDA improvements of 45.6%. The CTBT laboratory requirement for a 140 Ba MDA is achievable after 1.5 days counting compared to 5–7 days using conventional systems. The system consists of plastic scintillation plates that detect coincident cosmic-ray interactions within an HPGe gamma-spectrometer using the Canberra Lynx TM multi-channel analyser. The detector is remotely configurable using a TCP/IP interface and requires no dedicated coincidence electronics. It would be especially useful in preventing false-positives at remote station locations (e.g. Halley, Antarctica) where sample transfer to certified laboratories is logistically difficult. The improved sensitivity has been demonstrated for a CTBT air filter sample collected after the Fukushima incident

  8. Cosmic veto gamma-spectrometry for Comprehensive Nuclear-Test-Ban Treaty samples

    Science.gov (United States)

    Burnett, J. L.; Davies, A. V.

    2014-05-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a global network of monitoring stations that perform high-resolution gamma-spectrometry on air filter samples for the identification of 85 radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a novel cosmic veto gamma-spectrometer has been developed to improve the sensitivity of station measurements, providing a mean background reduction of 80.8% with mean MDA improvements of 45.6%. The CTBT laboratory requirement for a 140Ba MDA is achievable after 1.5 days counting compared to 5-7 days using conventional systems. The system consists of plastic scintillation plates that detect coincident cosmic-ray interactions within an HPGe gamma-spectrometer using the Canberra LynxTM multi-channel analyser. The detector is remotely configurable using a TCP/IP interface and requires no dedicated coincidence electronics. It would be especially useful in preventing false-positives at remote station locations (e.g. Halley, Antarctica) where sample transfer to certified laboratories is logistically difficult. The improved sensitivity has been demonstrated for a CTBT air filter sample collected after the Fukushima incident.

  9. Cosmic veto gamma-spectrometry for Comprehensive Nuclear-Test-Ban Treaty samples

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, J.L., E-mail: jonathan.burnett@awe.co.uk; Davies, A.V.

    2014-05-21

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a global network of monitoring stations that perform high-resolution gamma-spectrometry on air filter samples for the identification of 85 radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a novel cosmic veto gamma-spectrometer has been developed to improve the sensitivity of station measurements, providing a mean background reduction of 80.8% with mean MDA improvements of 45.6%. The CTBT laboratory requirement for a {sup 140}Ba MDA is achievable after 1.5 days counting compared to 5–7 days using conventional systems. The system consists of plastic scintillation plates that detect coincident cosmic-ray interactions within an HPGe gamma-spectrometer using the Canberra Lynx{sup TM} multi-channel analyser. The detector is remotely configurable using a TCP/IP interface and requires no dedicated coincidence electronics. It would be especially useful in preventing false-positives at remote station locations (e.g. Halley, Antarctica) where sample transfer to certified laboratories is logistically difficult. The improved sensitivity has been demonstrated for a CTBT air filter sample collected after the Fukushima incident.

  10. Detection of /sup 210/Pb in the lungs of smokers by in-vivo gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Berger, C.D.; Lane, B.H.

    1982-09-01

    Since mainstream smoke is highly enriched in /sup 210/Pb, alpha radiation from inhaled cigarette smoke particles has been proposed as a cancer-producing agent in cigarette smokers. /sup 210/Po and /sup 210/Pb have been observed in tobacco, cigarette smoke and in the lungs of smokers. Since /sup 210/Pb is highly enriched in mainstream smoke, there have been estimates of yearly excesses of /sup 210/Pb in the lungs of one-pack-a-day smokers of 3 to 10 pCi (0.11 to 0.37 Bq). The ORNL Whole Body Counter was used to verify this estimate by the methodology of high-resolution, in vivo gamma spectrometry. Measurements were made on 113 adult male non-radiation workers who have either smoked at least one pack of cigarettes per day for at least five years, or have never smoked cigarettes. An analysis-of-variance table was generated based on the Pb-ratio for each individual which revealed that there was no statistically significant increase in the amount of /sup 210/Pb in the lungs of smokers over those of non-smokers. Sources of error are also discussed.

  11. High resolution solar observations

    International Nuclear Information System (INIS)

    Title, A.

    1985-01-01

    Currently there is a world-wide effort to develop optical technology required for large diffraction limited telescopes that must operate with high optical fluxes. These developments can be used to significantly improve high resolution solar telescopes both on the ground and in space. When looking at the problem of high resolution observations it is essential to keep in mind that a diffraction limited telescope is an interferometer. Even a 30 cm aperture telescope, which is small for high resolution observations, is a big interferometer. Meter class and above diffraction limited telescopes can be expected to be very unforgiving of inattention to details. Unfortunately, even when an earth based telescope has perfect optics there are still problems with the quality of its optical path. The optical path includes not only the interior of the telescope, but also the immediate interface between the telescope and the atmosphere, and finally the atmosphere itself

  12. Radioactivity Measurement in the Detergent Products by Gamma Spectrometry

    International Nuclear Information System (INIS)

    Ksouri, Abir

    2009-01-01

    Our study focuses on the evaluation of the level of radioactivity in the detergents. We have determined the specific activities of gamma emitting radionuclides belonging to the natural families of uranium, thorium and potassium using gamma spectrometry. The activities of radionuclides ( 235 U, 238U , 226 Ra, 232 Th, 40K) and their descendants are below the minimum detectable activity for dishwasher products, soaps, bleaches and shampoos, whereas they are found to levels considered very low (between 0,2 and 13 Bq/kg on average) in the products washes linens. These values are always lower than those of raw materials, what is explained by the conservation of radioactive material throughout the manufacturing process. The effective dose due to external exposure estimated below the regulatory standard recommended (<1 mSv / year), allows us to show that detergent products are not contaminated by radioactivity, are healthy and do not have harmful radiological impact on the consumer.

  13. Characterization of radioactive orphan sources by gamma spectrometry

    International Nuclear Information System (INIS)

    Cruz W, H.

    2013-01-01

    The sealed radioactive sources are widely applicable in industry. They must have a permanent control and must be registered with the Technical Office of the National Authority (OTAN). However, at times it has identified the presence of abandoned sealed sources unknown to the owner. These sources are called 'orphan sources'. Of course these sources represent a high potential risk because accidents can trigger dire consequences depending on your activity and chemical form in which it presents the radioisotope. This paper describes the process and the actions taken to characterize two orphan radioactive sources from the smelter a Aceros Arequipa. For characterization we used a gamma spectrometry system using a detector NaI(Tl) 3″ x 3″ with a multichannel analyzer Nucleus PCA-II. The radioisotope identified was cesium - 137 ( 137 Cs) in both cases. Fortunately, the sources maintained their integrity would otherwise have generated significant pollution considering the chemical form of the radioisotope and easy dispersion. (author)

  14. Correction for decay during counting in gamma spectrometry

    International Nuclear Information System (INIS)

    Nir-El, Y.

    2013-01-01

    A basic result in gamma spectrometry is the count rate of a relevant peak. Correction for decay during counting and expressing the count rate at the beginning of the measurement can be done by a multiplicative factor that is derived from integrating the count rate over time. The counting time substituted in this factor must be the live time, whereas the use of the real-time is an error that underestimates the count rate by about the dead-time (DT) (in percentage). This error of underestimation of the count rate is corroborated in the measurement of a nuclide with a high DT. The present methodology is not applicable in systems that include a zero DT correction function. (authors)

  15. Use of gamma spectrometry for studying fuel plates

    International Nuclear Information System (INIS)

    Carteret, Y.; Schley, R.; Simonet, G.

    1979-01-01

    The programme of experimental irradiation performed at the CEA on the CARAMEL plate fuel was followed by gamma spectrometry, jointly with other techniques. The qualitative study of the distribution of fission products constitutes a source of information on the behavior of the fuel (temperature and structure) and enables its utilization limits to be predicted. The quantitative determination of short and long half life fission products makes it possible to calculate the specific power and specific burn-up. Carried out periodically, it is a means of checking the values obtained by the continuous measurement of cladding temperature, directly linked to the specific burn-up. At the end of irradiation, the results are compared against those achieved by neodymium analysis. The study of the change in gadolinium, a burnable poison, is an application of this technique [fr

  16. Determination of Natural Radioactivity in Building Materials with Gamma Spectrometry

    International Nuclear Information System (INIS)

    Turki, Faten

    2010-01-01

    In the setting of this work, the natural radioactivity of building materials used in Tunisia has been measured by gamma spectrometry. These products have been ground and dried at 100 degree for 12 h. Then, they have been homogenized, weighed and finally conditioned during 23 days in order to reach the radioactive equilibrium. The measures' results proved that all building materials studied except bauxite and the ESC clay, possess doses lower than the acceptable limit (1 mSv.an-1). However, the possibility of reinforcement of the natural radioactivity in some industry of building can exist. To insure that the cement, the most used in the world, don't present any radiological risk on the workers' health, a survey has been made in the factory - les Ciments de Bizerte - about its manufacture's process. The results of this survey showed that this product can be considered like a healthy product.

  17. Gammastic: towards a pseudo-gamma spectrometry in plastic scintillators

    International Nuclear Information System (INIS)

    Hamel, Matthieu; Dehe-Pittance, Chrystele; Coulon, Romain; Carrel, Frederick; Pillot, Philippe; Barat, Eric; Dautremer, Thomas; Montagu, Thierry; Normand, Stephane

    2013-06-01

    War against CBRN-E threats needs to continuously develop sensors with improved detection efficiency. More particularly, this topic concerns the NR controls for homeland security. A first analysis requires indeed a fast gamma spectrometry so as to detect potential special nuclear materials (SNM). To this aim, plastic scintillators could represent the best alternative for the production of large-scale, low-cost radiation portal monitors to be deployed on boarders, tolls, etc. Although they are known to be highly sensitive to gamma rays, due to their poor resolution, information relative to the nature of the SNM is tricky. Thus, only the Compton edge is obtained after interaction, and no information of the photoelectric peak is observed. This project concerns new developments on a possible pseudo-gamma spectrometry performed with plastic scintillators. This project is articulated on a combination of two developments: - The design of new materials most suitable for recovering the photoelectric peak after gamma interaction with the scintillator. This work concerns mainly plastic scintillators loading with heavy elements, such as lead or bismuth. - The analysis of the resulting signal with smart algorithms. This work is thus a pluri-disciplinary work performed at CEA LIST and embeds 4 main disciplines: MCNPX simulations (simulated spectra), chemistry of materials (preparation of various plastic scintillators with different properties), instrumentation (lab experiments) and smart algorithms. Really impressive results were obtained with the unfolding of simulated spectra at various energies (from 241 Am to 60 Co) and an innovative approach was proposed to counter-balance the quenching effect of luminescence by heavy elements in plastic scintillators. (authors)

  18. High resolution data acquisition

    Science.gov (United States)

    Thornton, Glenn W.; Fuller, Kenneth R.

    1993-01-01

    A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock (38) pulse train (37) and analog circuitry (44) for generating a triangular wave (46) synchronously with the pulse train (37). The triangular wave (46) has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter (18, 32) forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter (26) counts the clock pulse train (37) during the interval to form a gross event interval time. A computer (52) then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.

  19. ANL high resolution injector

    International Nuclear Information System (INIS)

    Minehara, E.; Kutschera, W.; Hartog, P.D.; Billquist, P.

    1985-01-01

    The ANL (Argonne National Laboratory) high-resolution injector has been installed to obtain higher mass resolution and higher preacceleration, and to utilize effectively the full mass range of ATLAS (Argonne Tandem Linac Accelerator System). Preliminary results of the first beam test are reported briefly. The design and performance, in particular a high-mass-resolution magnet with aberration compensation, are discussed. 7 refs., 5 figs., 2 tabs

  20. Ultra high resolution tomography

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, W.S.

    1994-11-15

    Recent work and results on ultra high resolution three dimensional imaging with soft x-rays will be presented. This work is aimed at determining microscopic three dimensional structure of biological and material specimens. Three dimensional reconstructed images of a microscopic test object will be presented; the reconstruction has a resolution on the order of 1000 A in all three dimensions. Preliminary work with biological samples will also be shown, and the experimental and numerical methods used will be discussed.

  1. High resolution (transformers.

    Science.gov (United States)

    Garcia-Souto, Jose A; Lamela-Rivera, Horacio

    2006-10-16

    A novel fiber-optic interferometric sensor is presented for vibrations measurements and analysis. In this approach, it is shown applied to the vibrations of electrical structures within power transformers. A main feature of the sensor is that an unambiguous optical phase measurement is performed using the direct detection of the interferometer output, without external modulation, for a more compact and stable implementation. High resolution of the interferometric measurement is obtained with this technique (transformers are also highlighted.

  2. Quantitative radiological characterization of waste. Integration of gamma spectrometry and passive/active neutron assay

    Energy Technology Data Exchange (ETDEWEB)

    Simone, Gianluca; Mauro, Egidio; Gagliardi, Filippo; Gorello, Edoardo [Nucleco S.p.A., Rome (Italy)

    2016-06-15

    The radiological characterization of drums through Non-Destructive Assay (NDA) techniques commonly relies on gamma spectrometry. This paper introduces the procedure developed in Nucleco for the NDA radiological characterization of drums when the presence of Special Nuclear Material (SNM) is expected/observed. The procedure is based on the integration of a gamma spectrometry in SGS mode (Segmented Gamma Scanner) and a passive/active neutron assay. The application of this procedure is discussed on a real case of drums. The extension of the integration procedure to other gamma spectrometry systems is also discussed.

  3. PEAKS: Computer code for solving partly overlapped photopeak in gamma spectrometry

    International Nuclear Information System (INIS)

    Jerez Vergueria, Sergio; Jerez Vergueria, Pablo

    1996-01-01

    The paper describes the main elements of the code according to purposes and contents. The PEAKS code is a useful tool of comfortable and easy handling for solving, partly overlapped photopeak in gamma spectrometry with NaI(Ti) detector

  4. Fission products control by gamma spectrometry in purex process solutions

    International Nuclear Information System (INIS)

    Goncalves, Maria Augusta

    1982-01-01

    This paper deals with a radiometric method for fission products analysisby gamma spectrometry. This method will be applied for fission productscontrol at the irradiated material processing facility, under construction inthe Instituto de Pesquisas Energeticas e Nucleares, SP, Brazil. Countinggeometry was defined taking into account the activities of process solutionsto be analysed, the remotely operated aliquotation device of analytical celland the available detection system. Natural and 19,91% enriched uraniumsamples were irradiated at IEAR-1 reactor in order to simulate thecomposition of Purex process solutions. After a short decay time, the sampleswere dissolved with HNO 3 and then, conditioned in standard flasks withdefined geometry. The spectra were obtained by a Ge(Li) semiconductordetector and analysed by the GELIGAM software system, losing a floppy-diskconnected to a PDP-11/05 computer. Libraries were prepared and calibrationswere made with standard sources to fit the programs to the analysis offission products in irradiated uranium solutions. It was possible to choosethe best program to be used in routine analysis with the obtained data.(author)

  5. Embedded gamma spectrometry: new algorithms for spectral analysis

    International Nuclear Information System (INIS)

    Martin-Burtart, Nicolas

    2012-01-01

    Airborne gamma spectrometry was first used for mining prospecting. Three main families were looked for: K-40, U-238 and Th-232. The Chernobyl accident acted as a trigger and for the last fifteen years, a lot of new systems have been developed for intervention in case of nuclear accident or environmental purposes. Depending on their uses, new algorithms were developed, mainly for medium or high energy signal extraction. These spectral regions are characteristics of natural emissions (K-40, U-238 and Th-232 decay chains) and fissions products (mainly Cs-137 and Co-60). Below 400 keV, where special nuclear materials emit, these methods can still be used but are greatly imprecise. A new algorithm called 2-windows (extended to 3), was developed. It allows an accurate extraction, taking the flight altitude into account to minimize false detection. Watching radioactive materials traffic appeared with homeland security policy a few years ago. This particular use of dedicated sensors require a new type of algorithms. Before, one algorithm was very efficient for a particular nuclide or spectral region. Now, we need algorithm able to detect an anomaly wherever it is and whatever it is: industrial, medical or SNM. This work identified two families of methods working under these circumstances. Finally, anomalies have to be identified. IAEA recommend to watch around 30 radionuclides. A brand new identification algorithm was developed, using several rays per element and avoiding identifications conflicts. (author) [fr

  6. Inventory control through gamma spectrometry at the enriched uranium laboratory

    International Nuclear Information System (INIS)

    Vicens, H.E.; Korob, R.O.; Goldschmidt, A.E.

    1987-01-01

    The enriched uranium laboratory processes alternatively uranium 90% and 20% enriched in U-235. The control of the isotopic composition of lots is made through mass spectrometry. In the laboratory operation wastes of both enrichments are generated and the recovery is performed with a time delay. To strengthen the administrative controls, avoid errors related to personnel replacement and/or deferred operations, it seemed suitable to adjust the gamma spectrometry as a fast, simple and available method to determine the enrichment. The laboratory work includes a wet and a dry process. The waste recovery necessarily involves the handling of liquid samples. For this reason, it was decided to determine the calibration curve for uranyl nitrate samples of fixed concentration and geometry. The samples were prepared from material purified through double precipitation of uranium peroxide and subsequent ignition to U 3 O 8 in platinum crucible, in tubular oven during 8 hours at 720 deg C. The preparation of samples, the measurement description, the discussion of results and the analysis of errors due to the presence of insoluble material and concentration changes are included. (Author)

  7. A Field Test of the New Portable Gamma Spectrometry System

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Jung-Ki; Park, Uk Ryang; Park, Seunghoon; Chung, Heejun; Kwak, Sung-Woo [Korea Institute of Nuclear Non-proliferation and Control, Daejeon (Korea, Republic of); Kim, Yongkwn [NuCare Medical Systems, Inc., Incheon (Korea, Republic of)

    2015-10-15

    In order to perform a field test of the system, the measurement of U-235 enrichment for nuclear fuel pellets was conducted along with the IAEA Physical Inventory Verification (PIV) inspection at the KEPCO Nuclear Fuel (KNF). The enrichment value of U-235 was calculated based on the total counts of the 185.7 keV photopeak and compared with the reference line, drawn by certified sources. The goal of this study is to experimentally evaluate the system performance of the developed system. In this study, the new portable gamma spectrometry system showed a good linearity (R{sup 2}=1) but overestimated the enrichment values than IAEA inspection device. It could be caused by the stability of the new system since it found, right after this measurement, that the accuracy of the system gradually increases and becomes stable over time. Further steps will optimize the design parameter based on these results and repeat measurement with the same samples under the same environment.

  8. Burn-up measurements coupling gamma spectrometry and neutron measurement

    Energy Technology Data Exchange (ETDEWEB)

    Toubon, H.; Pin, P. [AREVA/CANBERRA, 1 rue des Herons, 78182 St Quentin-en-Yvelines Cedex (France); Lebrun, A. [IAEA, Wagramer Strasse 5, PO Box 100, Vienna (Austria); Oriol, L.; Saurel, N. [CEA Cadarache, 13108 Saint Paul Lez Durance Cedex (France); Gain, T. [AREVA/COGEMA Reprocessing Business Unit, La Hague, 50444 Beaumont Hague Cedex (France)

    2006-07-01

    The need to apply for burn-up credit arises with the increase of the initial enrichment of nuclear fuel. When burn-up credit is used in criticality safety studies, it is often necessary to confirm it by measurement. For the last 10 years, CANBERRA has manufactured the PYTHON system for such measurements. However, the method used in the PYTHON itself uses certain reactor data to arrive at burn-up estimates. Based on R and D led by CEA and COGEMA in the framework of burn-up measurement for burn-up credit and safeguards applications, CANBERRA is developing the next generation of burn-up measurement device. This new product, named SMOPY, is able to measure burn-up of any kind of irradiated fuel assembly with a combination of gamma spectrometry and passive neutron measurements. The measurement data is used as input to the CESAR depletion code, which has been developed and qualified by CEA and COGEMA for burn-up credit determinations. In this paper, we explain the complementary nature of the gamma and neutron measurements. In addition, we draw on our previous experience from PYTHON system and from COGEMA La Hague to show what types of evaluations are required to qualify the SMOPY system, to estimate its uncertainties, and to detect discrepancies in the fuel data given by the reactor plant to characterize the irradiated fuel assembly. (authors)

  9. Fisson product control by gamma spectrometry in Purex process solutions

    International Nuclear Information System (INIS)

    Goncalves, Maria A.; Matsuda, H.T.

    1982-01-01

    A radiometric method for fission product analysis by gamma spectrometry, to be applied for fission product control at an irradiated material processing facility, is described. Counting geometry was defined taking into account the activities of process solutions to be analysed, the remotely operated aliquotation device of the analytical cell and the available detection system. Natural and 19,91% enriched uranium samples were irradiated in order to simulate the composition of Purex process solutions. After a short decay time the samples were dissolved with HNO 3 and then conditioned in standard flasks with defined geometry. The spectra were obtained by a Ge(Li) semiconductor detector and analysed by the GELIGAM software system, using a floppy-disk connected to a PDP-11/05 computer. Libraries were prepared and calibrations were made with standard sources to fit the analysis of fission products in irradiated uranium solutions. It was possible to choose the best program to be used in routine analysis with the obtained data. (Author) [pt

  10. Burn-up measurements coupling gamma spectrometry and neutron measurement

    International Nuclear Information System (INIS)

    Toubon, H.; Pin, P.; Lebrun, A.; Oriol, L.; Saurel, N.; Gain, T.

    2006-01-01

    The need to apply for burn-up credit arises with the increase of the initial enrichment of nuclear fuel. When burn-up credit is used in criticality safety studies, it is often necessary to confirm it by measurement. For the last 10 years, CANBERRA has manufactured the PYTHON system for such measurements. However, the method used in the PYTHON itself uses certain reactor data to arrive at burn-up estimates. Based on R and D led by CEA and COGEMA in the framework of burn-up measurement for burn-up credit and safeguards applications, CANBERRA is developing the next generation of burn-up measurement device. This new product, named SMOPY, is able to measure burn-up of any kind of irradiated fuel assembly with a combination of gamma spectrometry and passive neutron measurements. The measurement data is used as input to the CESAR depletion code, which has been developed and qualified by CEA and COGEMA for burn-up credit determinations. In this paper, we explain the complementary nature of the gamma and neutron measurements. In addition, we draw on our previous experience from PYTHON system and from COGEMA La Hague to show what types of evaluations are required to qualify the SMOPY system, to estimate its uncertainties, and to detect discrepancies in the fuel data given by the reactor plant to characterize the irradiated fuel assembly. (authors)

  11. An analysis of the potassium concentrations of soft drinks by HPGe gamma spectrometry

    International Nuclear Information System (INIS)

    Guillermo Espinosa; Jose-Ignacio Golzarri; Ilsa Hernandez-Ibinarriaga

    2009-01-01

    Potassium, in a variety of compounds, occurs in abundance in the Earth's crust, and is an essential nutrient for human health. A naturally occurring radioactive isotope of potassium, 40 K, is found in the food and water that we consume. This paper presents the results of a gamma spectrometry analysis of the 40 K concentrations of a selection of commercial soft drinks. The 40 K concentrations are used to calculate the overall potassium concentrations. The analysis was carried out using a hyper-pure germanium (HPGe) detector with Ortec R ASPEC-927 multichannel analyzer module and GammaVision R software. This system was chosen for its high resolution and automatic data processing. The carbonated soft drinks (sodas) Coca-Cola R , Coca-Cola Light R (sold as Diet Coke R in the USA and other countries), Coca-Cola Zero R , Pepsi R , Pepsi Light R , Pepsi Max R , Big Cola R , Lulu-Cola R , Manzana Lift R , Sprite R and Fanta R and the mineral waters Ciel R and Penafiel R were analyzed. These brands are all international registered trademarks. The products analyzed were manufactured and bottled in Mexico. The results show a great variety of potassium concentrations in the different soft drinks analyzed (from 128.0 to 1113.1 mg/L). The concentration of potassium in the sodas, in conjunction with the amounts drank by one person in a year (180 L/year), are high enough to warrant consideration by public health authorities and by people to whom high potassium intakes pose a risk. (author)

  12. High resolution ultrasonic densitometer

    International Nuclear Information System (INIS)

    Dress, W.B.

    1983-01-01

    The velocity of torsional stress pulses in an ultrasonic waveguide of non-circular cross section is affected by the temperature and density of the surrounding medium. Measurement of the transit times of acoustic echoes from the ends of a sensor section are interpreted as level, density, and temperature of the fluid environment surrounding that section. This paper examines methods of making these measurements to obtain high resolution, temperature-corrected absolute and relative density and level determinations of the fluid. Possible applications include on-line process monitoring, a hand-held density probe for battery charge state indication, and precise inventory control for such diverse fluids as uranium salt solutions in accountability storage and gasoline in service station storage tanks

  13. Mapping of contaminated sites using mobile gamma spectrometry: Marcassin system

    International Nuclear Information System (INIS)

    Panza, F.; Demongeot, S.; Crosland, E.; Foissard, B.

    2015-01-01

    Document available in abstract form only. Full text of publication follows: As part of the development of a tool for use in a nuclear emergency, post-accident situations and contaminated sites, the Institute for Radiation Protection and Nuclear Safety (IRSN) has designed an instrument for mapping natural and artificial radioactivity in soil using in situ gamma spectrometry. The development of this mobile system is based on various studies initiated by IRSN. The tool, named MARCASSIN (Moyen Autoporteur pour la Realisation de Cartographies de l'Activite Sur Sites contamINes, or automotive resource for mapping radioactivity at contaminated sites), has already been used to characterise various types of sites: contaminated soil (Fukushima), old open-pit mines (centre of France) and environmental sites (Paris region). Mounted on a quad-type vehicle, the instrument is composed of a spectrometer, a radiation meter and a global positioning system. Using coordinates and nuclear data, results are given in the form of mapping indicating type of radionuclides, radioactivity level, dose rate and contamination distribution in real-time. To improve detection level above sites where radioactivity levels are low, the system also is capable of processing data. Two of these methods are as follows: the first, 're-meshing', improves the estimate of soil radioactivity by increasing measurement statistics. The results agree with the reference values (soil samples measured in the laboratory), even for normal environmental levels of radioactivity. The second method, for which a patent is pending, is based on a deconvolution of mapping data. Re-processing deducts the impulse response of MARCASSIN from the radiation flux measurements in order to restore the value sought, which is the soil emission rate by radiological energy or activity. A theoretical example demonstrates the possibilities of this method. (authors)

  14. Emergency response exercise of laboratories equipped with gamma spectrometry

    International Nuclear Information System (INIS)

    Mala, H.; Jezkova, T.; Rulik, P.; Beckova, V. et al.

    2014-01-01

    Seven laboratories equipped with semiconductor gamma spectrometry (HPGe detectors) are currently included in the Radiation Monitoring Network (RMN) in the Czech Republic. These laboratories have more than 30 spectrometric chains and approximately 20 'experts' and 70 'users' who would guarantee measurements during the radiological emergency (RE). The emergency exercise was carried out in 5 of them in 2014 (in 4 of them also in 2013). The aim was to test repeatedly their capacity in existing technical facilities and with current staff in the event of a RE and identify problems (bottlenecks) in the whole process from receipt of samples to entering the results into the central database of RMN. Duration of the exercise was 12 hours, due to the shortage of staff; work in one 12-hour shift is presumed during a RE, which the laboratories should be able to provide for 14 days. These exercise samples covered a wide range of commodities that would probably come to the laboratories during the RE (aerosol filters, sorbents for sorption of gaseous forms of iodine, fallout, surface and drinking waters, food chain components and soils). Some of the samples were previously spiked with 85 Sr, 88 Y and 40 K (in the exercise these nuclides represented actual contamination that would occur in RE); liquid samples were spiked with 85 Sr and 88 Y and bulk materials with 40 K.During the exercise almost 800 samples were analysed; in addition, the automatic gamma counter (GA) in Prague laboratory measured other 90 samples automatically during the night (samples were prepared during the day-shift). On the basis of the results the total measuring capacity of the laboratories of RMN CR was estimated at about 1300 samples per day. (authors)

  15. Analysis of burnt nuclear fuel elements by gamma-spectrometry

    International Nuclear Information System (INIS)

    Lammer, M.

    1978-01-01

    Gamma-spectrometry allows a non-destructive determination of the fission and activation product content of spent nuclear fuel. The concentration of some of these products depends significantly on the so-called fuel parameters which describe the irradiation history and the fuel composition. The use of these dependences for deriving ''unknown fuel parameters'' from measured fission product activities is investigated in this work. Relevant application fields are burnup determination, fuel testing and inspections within the nuclear materials safeguards programme. The present thesis investigates how these dependences can be used to derive unknown fuel parameters. The possibilities and basic limitations of deriving information from a measured gamma spectrum are considered on principle. The main conclusion is that only ratios of fission product activities allow the development of an interpretation method which is generally applicable to all types of fuel from different reactors. The dependence of activity ratios on cooling time, irradiation time, integrated and final neutron flux, fuel composition, as well as fission and breeding rates are then investigated and presented graphically in a way suitable for applicaton. These relationships can be used for the analysis of spent fuel, and the detailed procedures, which depend on the applicaton field, are worked out in this work. In order to test the interpretation methods, samples of nuclear fuel have been irradiated and the gamma spectra analysed. The methods developed in this work can be applied successfully to the analysis of burnt fuel in the frame of fuel testing programmes and to safeguards verification purposes. If however, apart from a gamma spectrum, no information on the investigated fuel is available, the above-mentioned parameters can be derived with low accuracy only. (author)

  16. GammaSem Proceedings - A Nordic seminar for users of gamma spectrometry

    International Nuclear Information System (INIS)

    Nunez, P.; Klemola, S.; Nielsen, Sven P.; Palsson, S.E.; Israelson, C.

    2010-03-01

    The project GammaSem was proposed to provide a forum for discussions and sharing of information on practical issues concerning gamma spectrometry and to establish a network of users of gamma spectrometry in the Nordic countries, thereby strengthening the collaboration and improving all participants' competence in practical gamma spectrometry. The seminars' focus was practical challenges met by the users themselves, rather than theoretical matters. Scientists and users of gamma spectrometry from all five Nordic countries were invited to the seminar, as well as scientist from the Baltic countries. A total of 75 people participated; representing 34 different universities, commercial companies, research institutes and also all Nordic authorities. During the seminar several key issues for follow-up were identified and working groups for addressing the identified problems were established. The working groups were: 1) Uncertainties and detections of limits 2) True summing coincidence 3) Monte Carlo simulations and efficiency transfer 4) Absorption (density corrections and geometries) 5) Mobile gamma spectrometry systems 6) Nuclear forensics (on special samples and special parts of the spectra). The identified topics will form the basis for the agenda of the next seminar in 2010. There, the different working groups will be invited to present their ideas/solutions to the relevant problems. (author)

  17. GammaSem Proceedings - A Nordic seminar for users of gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Nunez, P. (ed.) (Institute for Energy Technology (IFE) (Norway)); Klemola, S. (Radiation and Nuclear Safety Authority (STUK) (Finland)); Nielsen, Sven P. (Technical Univ. of Denmark, Risoe National Lab. for Sustainable Energy. Roskilde (Denmark)); Palsson, S.E. (Icelandic Radiation Safety Authority (IS)); Israelson, C. (National Institute of Radiation Protection (Denmark))

    2010-03-15

    The project GammaSem was proposed to provide a forum for discussions and sharing of information on practical issues concerning gamma spectrometry and to establish a network of users of gamma spectrometry in the Nordic countries, thereby strengthening the collaboration and improving all participants' competence in practical gamma spectrometry. The seminars' focus was practical challenges met by the users themselves, rather than theoretical matters. Scientists and users of gamma spectrometry from all five Nordic countries were invited to the seminar, as well as scientist from the Baltic countries. A total of 75 people participated; representing 34 different universities, commercial companies, research institutes and also all Nordic authorities. During the seminar several key issues for follow-up were identified and working groups for addressing the identified problems were established. The working groups were: 1) Uncertainties and detections of limits 2) True summing coincidence 3) Monte Carlo simulations and efficiency transfer 4) Absorption (density corrections and geometries) 5) Mobile gamma spectrometry systems 6) Nuclear forensics (on special samples and special parts of the spectra). The identified topics will form the basis for the agenda of the next seminar in 2010. There, the different working groups will be invited to present their ideas/solutions to the relevant problems. (author)

  18. Initial Gamma Spectrometry Examination of the AGR-3/4 Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Harp, Jason M.; Demkowicz, Paul A.; Stempien, John D.

    2016-11-01

    The initial results from gamma spectrometry examination of the different components from the combined third and fourth US Advanced Gas Reactor Fuel Development TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail particles surrounded by two graphitic diffusion rings (inner and outer) and a graphite sink were irradiated in the Idaho National Laboratory’s Advanced Test Reactor. Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. Additionally, inner and outer rings were also examined by gamma spectrometry both to evaluate the fission product inventory and the distribution of gamma-emitting fission products within the rings using gamma emission computed tomography. The cesium inventory of the scanned rings compares acceptably well with the expected inventory from fission product transport modeling. The inventory of the graphite fission product sinks is also being evaluated by gamma spectrometry.

  19. Sodium fast reactor power monitoring using gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Coulon, R.; Normand, S.; Barbot, L.; Domenech, T.; Kondrasovs, V.; Corre, G.; Frelin, A.M. [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, CEA - Saclay DRT/LIST/DETECS/SSTM, Batiment 516 - P.C. no 72, Gif sur Yvette, F-91191 (France); Montagu, T.; Dautremer, T.; Barat, E. [CEA, LIST, Laboratoire Processus Stochastiques et Spectres (France); Ban, G. [ENSICAEN (France)

    2009-06-15

    This work deals with the use of high flux gamma spectrometry to monitor the fourth generation of sodium fast reactor (SFR) power. The simulation study part of this work has shown that power monitoring in a short time response and with a good accuracy is possible. An experimental test is under preparation at the French SFR Phenix experimental reactor to validate simulation studies. First, physical calculations have been done to correlate gamma activity to the released thermal power. Gamma emitter production rate in the reactor core was calculated with technical and nuclear data as the sodium velocity, the atomic densities, Phenix neutron spectrum and incident neutron cross-sections of reactions producing gamma emitters. A thermal hydraulic transfer function was used for modeling primary sodium flow in our calculations. For the power monitoring problematic, use of a short decay period gamma emitter will allow to have a very fast response system without cumulative effect. We have determined that the best tagging agent is 20F which emits 1634 keV energy photons with a decay period of 11 s. The gamma spectrum was determined by flux point and a pulse high tally MCNP5.1.40 simulation and shown the possibility to measure the signal of this radionuclide. The experiment will be set during the reactor 'end life testing'. The Delayed Neutron Detection (DND) room has been chosen as the best available location on Phenix reactor to measure this kind of radionuclide due to a short transit time from reactor core to measurement sample. This location is optimum for global power measurement because homogenized sampling in the reactor hot pool. The main spectrometer is composed of a coaxial high purity germanium diode (HPGe) coupled with a transistor reset preamplifier. The HPGe diode signal will be processed by the Adonis digital signal processing due to high flux and fast activity measurement. Post-processing softwares will be used to limit statistical problems of the

  20. GammaSem Proceedings. A Nordic seminar for users of gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Straalberg, E. (ed.) (Institute for Energy Technolgy (Norway)); Berg, K. (National Institute of Radiation Protection (Denmark)); Dowdall, M. (Norwegian Radiation Protection Authority (Norway)) (and others)

    2010-11-15

    The project GammaSem was proposed to the NKS in 2008. The aim of the project was to arrange two seminars for users of gamma spectrometry, in 2009 and 2010. The seminars were meant to provide a forum for discussions and sharing of information on practical issues concerning gamma spectrometry and initiate a network of gamma spectrometry users in the Nordic countries. Such a Nordic network should strengthen the collaboration between laboratories and improve all participants' competence in practical gamma spectrometry. Both seminars' focus was practical challenges met by the users themselves, rather than theoretical matters. Scientists and users of gamma spectrometry from all five Nordic countries were invited to the seminar, as well as scientist from the Baltic countries. A total of 65 people signed up for GammaSem 2010; representing 30 different universities, commercial companies, research institutes and authorities. The working group concept as presented at last year's GammaSem, has not worked out as intended. The reason for this is probably because most of the laboratories that signed up to join the working groups, signed up because they wanted to learn more about the different subjects. In combination with the fact that no funding was made available for the working groups, it was difficult to establish goals on what to achieve. None of the working groups applied for funding from the NKS (or elsewhere) to establish separate projects. There is a big need for more cooperation and for training within the field of gamma spectrometry. This fact has been proved through these two seminars, both by the many different topics that have been discussed, but also by the huge interest for participating in the suggested series of workshop. The GammaSem seminars have thus provided a much welcomed starting point for a broader Nordic collaboration. (Author)

  1. GammaSem Proceedings. A Nordic seminar for users of gamma spectrometry

    International Nuclear Information System (INIS)

    Straelberg, E.; Berg, K.; Dowdall, M.

    2010-11-01

    The project GammaSem was proposed to the NKS in 2008. The aim of the project was to arrange two seminars for users of gamma spectrometry, in 2009 and 2010. The seminars were meant to provide a forum for discussions and sharing of information on practical issues concerning gamma spectrometry and initiate a network of gamma spectrometry users in the Nordic countries. Such a Nordic network should strengthen the collaboration between laboratories and improve all participants' competence in practical gamma spectrometry. Both seminars' focus was practical challenges met by the users themselves, rather than theoretical matters. Scientists and users of gamma spectrometry from all five Nordic countries were invited to the seminar, as well as scientist from the Baltic countries. A total of 65 people signed up for GammaSem 2010; representing 30 different universities, commercial companies, research institutes and authorities. The working group concept as presented at last year's GammaSem, has not worked out as intended. The reason for this is probably because most of the laboratories that signed up to join the working groups, signed up because they wanted to learn more about the different subjects. In combination with the fact that no funding was made available for the working groups, it was difficult to establish goals on what to achieve. None of the working groups applied for funding from the NKS (or elsewhere) to establish separate projects. There is a big need for more cooperation and for training within the field of gamma spectrometry. This fact has been proved through these two seminars, both by the many different topics that have been discussed, but also by the huge interest for participating in the suggested series of workshop. The GammaSem seminars have thus provided a much welcomed starting point for a broader Nordic collaboration. (Author)

  2. Airborne gamma spectrometry - towards integration of European operational capability

    International Nuclear Information System (INIS)

    Toivonen, H.

    2003-01-01

    Full text: A nuclear threat can take several forms. The fallout from nuclear weapons or from an accident in a nuclear power reactor may contaminate a large area (>>100,000 km 2 ) whereas the dispersion of single sources, either accidentally or deliberately (dirty bomb), contaminates a much smaller area, perhaps only a few thousand square kilometres or less. Airborne gamma spectrometry (AGS) plays an important role in providing detailed information an the dispersion of radioactive materials. AGS using a fixed-wing or a rotary-wing aircraft is at its best in fallout mapping and in searching for orphan sources. Plume tracking could be a third application but is very complex, and there is a risk of vehicle contamination, which would deteriorate mission capability in the later phases of an accident. Because of obvious advantages, unmanned aerial vehicles could be used to monitor the release rate at the site of an accident and perhaps the plume itself. The aim of the present paper is to discuss ways to utilize existing European airborne monitoring capabilities for multilateral assistance in an accident and to give some thoughts to how an integrated system could be developed to take into account various national measuring strategies. In a large-scale accident, it is to be expected that the European countries use their radiological resources to map their own territory. It is realistic to think of assistance by transferring equipment and staff to another country only in accident scenarios where a country or countries with essential AGS capability would not have been affected by the fallout. Various AGS survey results can be fused only if a common platform for data exchange is available. Formats and protocols have been developed for special cases (ECCOMAGS, Nuclear Fission Safety, 4 th and 5 th Framework Programmes) but there are no universal solutions applicable to different situations and Instruments. The hardware and software among the European AGS teams are tailor

  3. Emergency response exercise of laboratories equipped with gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mala, Helena; Rulik, Petr; Jezkova, Tereza; Beckova, Vera [National Radiation Protection Institute (SURO), 140 00 Praha 28 (Czech Republic)

    2014-07-01

    At present 7 laboratories equipped with semiconductor gamma spectrometry (HPGe detectors) are included in the Radiation Monitoring Network (RMN) in the Czech Republic. These laboratories have 31 spectrometric chains and approximately 20 'experts' and 70 'users' who would guarantee measurements during a radiological emergency (RE). The stress exercise (a load test) was carried out in 4 of them. The aim was to test their measuring capacity in existing technical facilities and staff in the event of a RE and identify problems (bottlenecks) in the whole process from receipt of samples to entering the results into the central database of RMN. Duration of the exercise was 8 to 14 hours. Due to lack of staff, work in one 12-hour shift during a RE is presumed, which the laboratories should be able to provide for 14 days. Exercise samples covered a wide range of commodities that would probably come to the laboratories during RE (aerosol filters, adsorbed gaseous forms of iodine, fallout, surface and drinking waters, food chain components and soils). Some of the samples were previously spiked with {sup 85}Sr, {sup 88}Y and {sup 40}K (these nuclides represented actual nuclides that would occur in RE); soil samples contained higher values of {sup 137}Cs activity originating from the Chernobyl accident. Almost 40 employees took part in the exercise and measurements were carried out at 18 spectrometric chains. An automatic gamma counter which allows automatic operation of two HPGe detectors including the analysis of the spectra with a storage for up to 180 sample containers was operating in one of the laboratories involved in the exercise. The procedures in individual laboratories varied slightly depending on the staff and laboratory space available. During the exercise about 700 samples were evaluated; in addition, gamma-automat measured other 80 samples in the 'night shift'. 700 samples, this means 40 samples per a spectrometric chain or, from

  4. A comparative study of 232Th and 238U activity estimation in soil samples by gamma spectrometry and neutron activation analysis technique

    International Nuclear Information System (INIS)

    Anilkumar, Rekha; Anilkumar, S.; Narayani, K.; Babu, D.A.R.; Sharma, D.N.

    2012-01-01

    Neutron activation analysis (NAA) is a well-established analytical technique. It has many advantages as compared to the other commonly used techniques. NAA can be performed in a variety of ways depending on the element, its activity level in the sample, interference from the sample matrix and other elements, etc. This technique is used to get high analytical sensitivity and low detection limits (ppm to ppb). The high sensitivity is due to the irradiation at high neutron flux available from the research reactors and the activity measurement is done using high resolution HPGe detectors. In this paper, the activity estimation of soil samples using neutron activation and direct gamma spectrometry methods are compared. Even though the weights of samples considered and samples preparation methods are different for these two methods, the estimated activity values are comparable. (author)

  5. Methods for the analysis of the overlapped peaks in analytical gamma-spectrometry

    International Nuclear Information System (INIS)

    Sterlinski, S.; Wasek, M.

    1989-01-01

    A new simple method for the quantitative analysis of the doublet peaks in Ge(Li) or HPGe gamma-spectrometry is presented. No assumptions on the shape of the peaks in gamma-ray spectra being measured are required. Special feature of the method proposed is its usefulness for the analysis of closed doublets. 7 refs., 6 figs. (author)

  6. Spent fuel scanning using the gamma spectrometry bench at Osiris. Power and burnup determination

    International Nuclear Information System (INIS)

    Cerles, J.-M.; Simonet, Genevieve.

    1976-01-01

    The Saclay Nuclear Research Center is provided with an original gamma spectrometry facility located inside the pool of the Osiris reactor. It is intended for the gamma scanning of fuel elements irradiated in Osiris or elements of any other origin. The principal characteristics of this facility are given. Special emphasis is put on its [fr

  7. The first results of measurements in military hospital laboratory for gamma spectrometry analysis

    International Nuclear Information System (INIS)

    Jankovic, Lj.; Pantelic, G.; Misovic, M.

    1997-01-01

    In this paper we present the basic features of the equipment for gamma spectrometry analysis and the first measurements results of the 134 Cs and 137 Cs activities. Gamma spectrum is measured using HP GE Detector. The obtained results show low level activities of the 134 Cs and 137 Cs in the environment. (author)

  8. Some aspects related to the high performance in gamma spectrometry

    International Nuclear Information System (INIS)

    Vieru, Gheorghe; Mihaiu, Ramona; Nistor, Viorica

    2010-01-01

    Full text: Gamma spectroscopy is the science (or art) of identification and/or quantification of radionuclides through gamma-ray energy spectrum analysis. It is a recognized technique, well illustrated by the following examples: environmental radioactivity monitoring, health physics personnel monitoring, reactor corrosion monitoring, nuclear materials safeguards and homeland security, as well as nuclear forensics, materials testing, nuclear medicine and radiopharmaceuticals, and industrial process monitoring. Within the Reliability and Testing Laboratory of INR Pitesti there is now available such a detector of high performance that includes all aspects related to cooling, signal processing (with a high resolution) and the dedicated software applications. At the present time, taking into account the 'nuclear renaissance' the new experimental testing laboratories require complete set-up rather than laboratories having a mixture of the old equipment. The paper presents the mechanically cooled HPGe spectrometers with an undergoing rapid evolution, which eliminate traditional intensive liquid nitrogen management. Also, there are described the digital signal processing virtually by eliminating system drift, and, at the same time, requiring recalibrations much less frequently. Another important aspect presented is related to the software applications, which cover a broad spectrum of nuclear measurement techniques. (authors)

  9. Berkeley High-Resolution Ball

    International Nuclear Information System (INIS)

    Diamond, R.M.

    1984-10-01

    Criteria for a high-resolution γ-ray system are discussed. Desirable properties are high resolution, good response function, and moderate solid angle so as to achieve not only double- but triple-coincidences with good statistics. The Berkeley High-Resolution Ball involved the first use of bismuth germanate (BGO) for anti-Compton shield for Ge detectors. The resulting compact shield permitted rather close packing of 21 detectors around a target. In addition, a small central BGO ball gives the total γ-ray energy and multiplicity, as well as the angular pattern of the γ rays. The 21-detector array is nearly complete, and the central ball has been designed, but not yet constructed. First results taken with 9 detector modules are shown for the nucleus 156 Er. The complex decay scheme indicates a transition from collective rotation (prolate shape) to single- particle states (possibly oblate) near spin 30 h, and has other interesting features

  10. Calibration of an air monitor prototype for a radiation surveillance network based on gamma spectrometry

    International Nuclear Information System (INIS)

    Baeza, A.; Caballero, J.M.; Corbacho, J.Á.; Ontalba-Salamanca, M.Á.; Vasco, J.

    2014-01-01

    The objective of this work is to present the improvements that have been made in quasi-real-time air radioactivity concentration monitors which were initially based on overall activity determinations, by incorporating gamma spectrometry into the current prototype. To this end it was necessary to develop a careful efficiency calibration procedure for both the particulate and the gaseous fractions of the air being sampled. The work also reports the values of the minimum detectable activity calculated for different isotopes and acquisition times. - Highlights: • Deficiencies of a commercial air monitoring system are detailed. • Gamma spectrometry introduction is the basis of the new prototype. • Efficiency calibration procedure is described for aerosol and gaseous fractions. • MDA is evaluated for different isotopes and acquisition times

  11. Homogenization of food samples for gamma spectrometry using tetramethylammonium hydroxide and enzymatic digestion

    International Nuclear Information System (INIS)

    Kimi Nishikawa; Abdul Bari; Abdul Jabbar Khan; Xin Li; Traci Menia; Semkow, T.M.

    2017-01-01

    We have developed a method of food sample preparation for gamma spectrometry involving the use of tetramethylammonium hydroxide (TMAH) and/or enzymes such as α-amylase or cellulase for sample homogenization. We demonstrated the effectiveness of this method using food matrices spiked with "6"0Co, "1"3"1I, "1"3"4","1"3"7Cs, and "2"4"1Am radionuclides, homogenized with TMAH (mixed salad, parmesan cheese, and ground beef); enzymes (α-amylase for bread, and cellulase for baked beans); or α-amylase followed by TMAH (cheeseburgers). Procedures were developed which are best compromises between the degree of homogenization, accuracy, speed, and minimizing laboratory equipment contamination. Based on calculated sample biases and z-scores, our results suggest that homogenization using TMAH and enzymes would be a useful method of sample preparation for gamma spectrometry samples during radiological emergencies. (author)

  12. Time sequence determination of parent–daughter radionuclides using gamma-spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, J. L.; Britton, R. E.; Abrecht, D. G.; Davies, A. V.

    2017-05-06

    The acquisition of time-stamped list (TLIST) data provides additional information useful to gamma-spectrometry analysis. A novel technique is described that uses non-linear least-squares fitting and the Levenberg-Marquardt algorithm to simultaneously determine parent-daughter atoms from time sequence measurements of only the daughter radionuclide. This has been demonstrated for the radioactive decay of short-lived radon progeny (214Pb/214Bi, 212Pb/212Bi) described using the Bateman first-order differential equation. The calculated atoms are in excellent agreement with measured atoms, with a difference of 1.3 – 4.8% for parent atoms and 2.4% - 10.4% for daughter atoms. Measurements are also reported with reduced uncertainty. The technique has potential to redefine gamma-spectrometry analysis.

  13. Design and fabrication of shielding for gamma spectrometry; Diseno y fabricacion de blindaje para espectrometria gamma

    Energy Technology Data Exchange (ETDEWEB)

    Mariano H, E

    1991-05-15

    To have a system of gamma spectrometry in the Radiological Mobile Unit No. 1 (UMOR-1) was designed and manufactured an armor-plating appropriate to this, to make analysis of radioactive samples in place in the event of a radiological emergency, besides being able to give support to the Management of Radiological Safety, and even to give service of sample analysis of other Institutions. (Author)

  14. Mass determination of U-233 and Pu-239 by gamma spectrometry technique

    International Nuclear Information System (INIS)

    Moraes, M.A.P.V. de; Pugliesi, R.

    1988-09-01

    The gamma spectrometry technique has been used for masses determinations of uranium-233 and plutonium-239, granted by AERE-HARWELL. A high purity Ge semicondutor detector was used and the total efficiency curve was obtained for the counting system in the energy range 13 KeV to 135 KeV. The calculated values for the masses compared with that obtained by means of gravimetry technique. (author) [pt

  15. The gamma spectrometry a powerful tool for irradiated fuel and fission products release studies

    International Nuclear Information System (INIS)

    Pontillon, Y.; Roure, C.; Lacroix, B.; Martella, T.; Ducros, G.; Ravel, S.; Gleizes, B.

    2003-01-01

    Over the last decades, due to the potentially severe consequences of a nuclear incident and/or accident for surrounding populations as well as the environment, international safety authorities launched R and D programs in support of general policy on exploitation of nuclear energy. This increasing interest enabled starting of many research programs in CEA and particularly in Nuclear Energy Directorate (DEN). Most of them are devoted to (i) the source term of fission products (including gas) and actinides released from PWR fuel samples in normal or accident conditions, (ii) burn-up determination, (iii) isotopic repartition... by quantitative gamma spectrometry. In this context, the Department of Fuel Studies (DEC), part of the DEN, has acquired considerable experience in this field of research. In order to attain the required capabilities, specific technical facilities set up in shielded hot cells at the CEA-Grenoble and CEA-Cadarache have been developed. In particular, the researchers of the Department have developed several gamma scanning benches and a set of two thermal treatment devices, including the so-called 'VERCORS facility'. These devices are associated to on line quantitative gamma spectrometry, in order to measure emitted gas and fission products (FPs). The greatest asset of such installations is to ensure a high analytical experiments rate, and as a consequence to make parametrical approach of planned studies easier. The first part of the present communication focuses, on the one hand, on the peculiar aspects of the gamma spectrometry applied on irradiated fuel, mad on the other hand, on the technical aspect of the different facilities (i.e. quantitative gamma spectrometry apparatus and corresponding 'home made' software). The last part is devoted to the results which can be obtained with such installation. In particular, it will be explained how experimental programs on FPs and gas release in normal and/or accidental conditions can be conducted

  16. Design of an automatic sample changer for the measurement of neutron flux by gamma spectrometry

    International Nuclear Information System (INIS)

    Gago, Javier; Bruna, Ruben; Baltuano, Oscar; Montoya, Eduardo; Descreaux, Killian

    2014-01-01

    This paper presents calculus, selection and components design for the construction of an automatic system in order to measure neutron flux in a working nuclear reactor by the gamma spectrometry technique using samples irradiated on the RP-10 nucleus. This system will perform the measurement of interchanging 100 samples in a programed and automatic way, reducing operation time by the user and obtaining more accurate measures. (authors).

  17. Uranium Enrichment Determination of the InSTEC Sub Critical Ensemble Fuel by Gamma Spectrometry

    International Nuclear Information System (INIS)

    Borrell Munnoz, Jose L.; LopezPino, Neivy; Diaz Rizo, Oscar; D'Alessandro Rodriguez, Katia; Padilla Cabal, Fatima; Arbelo Penna, Yunieski; Garcia Rios, Aczel R.; Quintas Munn, Ernesto L.; Casanova Diaz, Amaya O.

    2009-01-01

    Low background gamma spectrometry was applied to analyze the uranium enrichment of the nuclear fuel used in the InSTEC Sub Critical ensemble. The enrichment was calculated by two variants: an absolute method using the Monte Carlo method to simulated detector volumetric efficiency, and an iterative procedure without using standard sources. The results confirm that the nuclear fuel of the ensemble is natural uranium without any additional degree of enrichment. (author)

  18. High resolution metric imaging payload

    Science.gov (United States)

    Delclaud, Y.

    2017-11-01

    Alcatel Space Industries has become Europe's leader in the field of high and very high resolution optical payloads, in the frame work of earth observation system able to provide military government with metric images from space. This leadership allowed ALCATEL to propose for the export market, within a French collaboration frame, a complete space based system for metric observation.

  19. Application of fussy mathematics to the data processing of surface gamma spectrometry for gold exploration

    International Nuclear Information System (INIS)

    Huang Zheming.

    1990-01-01

    This paper introduces a new method by applying fuzzy mathematics to the data processing of uranium thorium and potassium, these data were detected from surface gamma spectrometry in the field and can be used to make quantitative interpretation for delineating gold mineralization in the favourable area. This method provides a rapid means for expanding and tracing gold deposits or occurrences and for prospecting gold deposits of the same kind and also provides an effective means for engineering design in uncovering exploration. It is of high efficiency, low cost and worth popularizing. It can be also used to look for other metallic and nonmetallic ore deposits

  20. Source term estimation based on in-situ gamma spectrometry using a high purity germanium detector

    International Nuclear Information System (INIS)

    Pauly, J.; Rojas-Palma, C.; Sohier, A.

    1997-06-01

    An alternative method to reconstruct the source term of a nuclear accident is proposed. The technique discussed here involves the use of in-situ gamma spectrometry. The validation of the applied methodology has been possible through the monitoring of routine releases of Ar-41 originating at a Belgian site from an air cooled graphite research reactor. This technique provides a quick nuclide specific decomposition of the source term and therefore will be have an enormous potential if implemented in nuclear emergency preparedness and radiological assessments of nuclear accidents during the early phase

  1. Results of the 1988 interlaboratory comparison on the gamma spectrometry of dried whey

    International Nuclear Information System (INIS)

    Wiechen, A.; Tait, D.; Bundesanstalt fuer Milchforschung, Kiel

    1988-01-01

    Following the accident in Chernobyl in 1986 the number of units available for monitoring radioactivity, mainly gamma spectrometers, has been increased considerably in the Federal Republic of Germany. Furthermore, new legislation requires that all official monitoring laboratories verify the quality of their analytical technique by participating in interlaboratory comparison studies organized by Federal institutions. Such a study was therefore organized in March 1988. 86 laboratories collaborated on the gamma-spectrometry analysis of the radionuclides Cs-137, Cs-134 and K-40 in dried whey. This paper describes the statistical evaluation of the 144 sets of data received. The results of the study were surprisingly good. (orig./DG) [de

  2. A study for natural radioactivity levels in some soil samples using gamma spectrometry

    International Nuclear Information System (INIS)

    Mohamed, Yousif Hassab El Rasoul

    1997-05-01

    The purpose of this study was to investigate a few selected soil samples and to study their natural radioactivity using gamma spectrometry. The first sample was a rock phosphate from Nuba mountains region which is being considered as a low cost fertilizer. Another sample came from Miri lake area (Nuba mountains) which is known to have elevated natural radioactivity level. The other four samples came from different other regions in Sudan for comparison. The idea was to identify the radioactive nuclides present in these soil samples, to trace their sources and to determine the activity present in them. (Author)

  3. Study of different filtering techniques applied to spectra from airborne gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Wilhelm, Emilien; Gutierrez, Sebastien; Reboli, Anne; Menard, Stephanie; Nourreddine, Abdel-Mjid [Commissariat a l' Energie Atomique et aux energies alternatives - CEA, DAM, DIF F-91297 Arpajon (France); Arbor, Nicolas [Institut Pluridisciplinaire Hubert Curien, UMR 7178 Universite de Strasbourg-CNRS, 23 rue du Loess, BP 28, F-67037 Strasbourg Cedex 2 (France)

    2015-07-01

    One of the features of spectra obtained by airborne gamma spectrometry is low counting statistics due to the short acquisition time (1 s) and the large source-detector distance (40 m). It leads to considerable uncertainty in radionuclide identification and determination of their respective activities from the windows method recommended by the IAEA, especially for low-level radioactivity. The present work compares the results obtained with filters in terms of errors of the filtered spectra with the window method and over the whole gamma energy range. The results are used to determine which filtering technique is the most suitable in combination with some method for total stripping of the spectrum. (authors)

  4. Overview of gamma spectrometry measurement devices developed by ENVINET a.s

    International Nuclear Information System (INIS)

    Sidlova, V.; Slama, L.; Holecek, V.; Chaloupkova, H.

    2008-01-01

    This paper demonstrates the development and usage of the devices designed for non- destructive radiological characterization of radioactive waste. All ..systems are based on gamma-spectrometry and are divided into two categories - stable and mobile. Stable ones involve only measurement in fixed detector - package configuration. They are used for assessment of packaged waste, mainly in drums. Mobile ones are flexible and allow measurement of a wide range of objects from various positions and can be also transported to arbitrary location. The calibration of such systems is performed by means of appropriate software which allows computation of full-energy peak efficiency in various configurations. (authors)

  5. Results from an interlaboratory exercise on the determination of plutonium isotopic ratios by gamma spectrometry

    International Nuclear Information System (INIS)

    Ottmar, H.

    1981-07-01

    Results form interlaboratory comparison measurements on the determination of plutonium isotopic ratios by gamma spectrometry, organized by the ESARDA Working Group on Techniques and Standards for Nondestructive Analysis, are presented and discussed. Nine laboratories from nine countries or international organizations participated in the intercomparison exercise, which included both laboratories' own measurements on the plutonium isotopic reference materials NBS-SRM 946, 947, 948 and comparison analyses of gamma spectra from these materials distributed to the participating laboratories. Results from the intercomparison analyses have been used to reevaluate some gamma branching intensity ratios required for plutonium isotopic ratio measurements. (orig.) [de

  6. The central gamma spectrometry laboratory of the GSF Institute of Radiation Protection

    International Nuclear Information System (INIS)

    Ruckerbauer, F.; Dietl, F.; Winkler, R.

    1997-01-01

    Since the middle of 1995 the WG Radioecology is operating the central gamma spectrometry laboratory of the GSF-Institute of Radiation Protection. The main scope of the laboratory is the gamma spectrometric analysis of samples within the research program of the institute and within joint programs with other institutes of the GSF research center. In the present report set-up and technical data of the measuring equipment, the central operating and data evaluation system and measures for quality assurance are described. At that time 18 semiconductor detectors are available for gamma spectrometric sample analysis which is standardized with respect to operation, evaluation algorithms, nuclide data, data safety and documentation. (orig.) [de

  7. Measuring the radium quartet (228Ra, 226Ra, 224Ra, 223Ra) in seawater samples using gamma spectrometry

    International Nuclear Information System (INIS)

    Beek, P. van; Souhaut, M.; Reyss, J.-L.

    2010-01-01

    Radium isotopes are widely used in marine studies (eg. to trace water masses, to quantify mixing processes or to study submarine groundwater discharge). While 228 Ra and 226 Ra are usually measured using gamma spectrometry, short-lived Ra isotopes ( 224 Ra and 223 Ra) are usually measured using a Radium Delayed Coincidence Counter (RaDeCC). Here we show that the four radium isotopes can be analyzed using gamma spectrometry. We report 226 Ra, 228 Ra, 224 Ra, 223 Ra activities measured using low-background gamma spectrometry in standard samples, in water samples collected in the vicinity of our laboratory (La Palme and Vaccares lagoons, France) but also in seawater samples collected in the plume of the Amazon river, off French Guyana (AMANDES project). The 223 Ra and 224 Ra activities determined in these samples using gamma spectrometry were compared to the activities determined using RaDeCC. Activities determined using the two techniques are in good agreement. Uncertainties associated with the 224 Ra activities are similar for the two techniques. RaDeCC is more sensitive for the detection of low 223 Ra activities. Gamma spectrometry thus constitutes an alternate method for the determination of short-lived Ra isotopes.

  8. Burn-Up Determination by High Resolution Gamma Spectrometry: Spectra from Slightly-Irradiated Uranium and Plutonium between 400-830 keV

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, R S; Ronqvist, N

    1966-08-15

    Previously published studies of the short-cooled fission product spectra of irradiated uranium have been severely restricted by the poor energy resolution of the sodium iodide detectors used. In this report are presented fission product spectra of irradiated uranium and plutonium obtained by means of a lithium-drifted germanium detector. The resolved gamma peaks have been assigned to various fission products by correlation of measured energy and half-life values with published data. By simultaneous study of the spectra of two irradiated mixtures of plutonium and uranium, the possibility of using the activities of Ru-103 and Ru-106 as a measure of the relative fission rate in U-235 and Pu-239 has been briefly examined.

  9. Burn-Up Determination by High Resolution Gamma Spectrometry: Spectra from Slightly-Irradiated Uranium and Plutonium between 400-830 keV

    International Nuclear Information System (INIS)

    Forsyth, R.S.; Ronqvist, N.

    1966-08-01

    Previously published studies of the short-cooled fission product spectra of irradiated uranium have been severely restricted by the poor energy resolution of the sodium iodide detectors used. In this report are presented fission product spectra of irradiated uranium and plutonium obtained by means of a lithium-drifted germanium detector. The resolved gamma peaks have been assigned to various fission products by correlation of measured energy and half-life values with published data. By simultaneous study of the spectra of two irradiated mixtures of plutonium and uranium, the possibility of using the activities of Ru-103 and Ru-106 as a measure of the relative fission rate in U-235 and Pu-239 has been briefly examined

  10. High-resolution ultrasonic spectroscopy

    Directory of Open Access Journals (Sweden)

    V. Buckin

    2018-03-01

    Full Text Available High-resolution ultrasonic spectroscopy (HR-US is an analytical technique for direct and non-destructive monitoring of molecular and micro-structural transformations in liquids and semi-solid materials. It is based on precision measurements of ultrasonic velocity and attenuation in analysed samples. The application areas of HR-US in research, product development, and quality and process control include analysis of conformational transitions of polymers, ligand binding, molecular self-assembly and aggregation, crystallisation, gelation, characterisation of phase transitions and phase diagrams, and monitoring of chemical and biochemical reactions. The technique does not require optical markers or optical transparency. The HR-US measurements can be performed in small sample volumes (down to droplet size, over broad temperature range, at ambient and elevated pressures, and in various measuring regimes such as automatic temperature ramps, titrations and measurements in flow.

  11. High Resolution Thermometry for EXACT

    Science.gov (United States)

    Panek, J. S.; Nash, A. E.; Larson, M.; Mulders, N.

    2000-01-01

    High Resolution Thermometers (HRTs) based on SQUID detection of the magnetization of a paramagnetic salt or a metal alloy has been commonly used for sub-nano Kelvin temperature resolution in low temperature physics experiments. The main applications to date have been for temperature ranges near the lambda point of He-4 (2.177 K). These thermometers made use of materials such as Cu(NH4)2Br4 *2H2O, GdCl3, or PdFe. None of these materials are suitable for EXACT, which will explore the region of the He-3/He-4 tricritical point at 0.87 K. The experiment requirements and properties of several candidate paramagnetic materials will be presented, as well as preliminary test results.

  12. High resolution tomographic instrument development

    International Nuclear Information System (INIS)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational

  13. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  14. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  15. Determination of 226Ra by gamma spectrometry: study of packaging vial of sample for analysis

    International Nuclear Information System (INIS)

    Carneiro, Andre Cavalcanti

    2015-01-01

    Determination of radioactivity levels of 226 Ra by gamma spectrometry in a sample is based on measurements of 214 Pb and 214 Bi, daughters of 222 Rn. Because radon is a gas, it can leak from the sample vial or accumulate on the upper empty it. If the vial has any crack, there will be loss of gas, which will cause error in determining the 226 Ra concentration. One possible cause of cracks in the vials, that houses standards and samples, is the radiolysis action in the vial material, usually a polymer. As the demand 226 Ra analysis in different matrices (geological samples, food, plants, etc.) is increasing, it was decided to study some polymer vials available on the market, to verify the feasibility to be used when is applied the analysis method using gamma spectrometry. Four types of polymer vials have been studied. The radiation doses in walls of the vials caused by natural radionuclides present in the sample were simulated using gamma irradiation. Tests, such as compressive strength test and tightness, were applied to the irradiated and non-irradiated vials. First, to verify the effect of radiolysis on the vial material and also if there was 222 Rn diffusion in their walls. These preliminary results pointed out that the acrylic vials are the best option of packaging samples for analysis. This study should be repeated in a larger number of samples for a better evaluation. (author)

  16. Determination of 7BE in soil sample by gamma spectrometry for erosion researchs

    International Nuclear Information System (INIS)

    Esquivel, Alexander D.; Kastner, Geraldo F.; Amaral, Angela M.; Monteiro, Roberto Pellacani G.; Moreira, Rubens M.

    2015-01-01

    Cosmogenic 7 Be is a natural radiotracer produced in the stratosphere and troposphere and reached to the Earth surface via wet and dry fallout and hence its measurement for research of erosion in soils is very significant. The 7 Be radio analyse based on gamma spectrometry technique has been a routine methodology for decades and although is the reference procedure is not free of analytical interference. 7 Be is a β-γ emitting radionuclide (Eγ = 477.59 keV, T½ = 53.12d) and depending on the chemical profile of the soil its determination is susceptible to 228 Ac (E γ = 478.40 keV, T½ = 6.15h) interference. The aim of this work was to establish an analytical protocol for the 7 Be determination in soil samples from Juatuba-Mg region in different sampling periods of dry and rainy seasons for erosion studies and to establish some methodologies for evaluating and correcting the interference level of 228 Ac in the 7 Be activity measurements by gamma spectrometry. (author)

  17. Results from the first national in-situ gamma spectrometry survey of the United Kingdom

    International Nuclear Information System (INIS)

    Tyler, A.

    2004-01-01

    In-situ gamma spectrometry was introduced for the first time as part of a national soil and herbage pollution survey of the United Kingdom (UK) in 2002. The aim of introducing the in-situ approach was to evaluate its potential for replacing the conventional soil sampling approach in environmental monitoring. A total of 138 points were measured across the whole of the UK on a 50 km grid, encompassing a complete spectrum of soil types, geology (providing a range of natural radioactive backgrounds) and anthropogenic radioactivity (primarily derived from atmospheric weapons testing and Chernobyl fallout). Ten calibration sites were set up to derive an in-situ calibration from spatially distributed sampling points, designed to match the spatial response of the in-situ detector at 1 m above the ground. The importance of variations in the vertical activity distributions of 137 Cs on the in-situ detector calibration was verified and the advantages and disadvantages of implementing a forward scattering type approach for real time in-situ correction was evaluated. The accuracy of the in-situ calibrations was evaluated for the remaining 128 sites by independent comparison with soil core derived estimates of specific activity concentrations and inventories of a range of natural and anthropogenic gamma emitting radionuclides. Air kerma measurements were also derived from the in-situ gamma spectrometry measurements and compared with conventional GM tube derived estimates. (authors)

  18. Decision Threshold and Detection Limit in Spectrometric Measurements. Part 1: Application to Gamma Spectrometry

    International Nuclear Information System (INIS)

    Perez, C.; Gasco, C.; Lopez, M. A.

    2010-01-01

    This report summarised the author's lecture of the advanced gamma spectrometry course organised by CIEMAT. The characteristic limits determination in gamma spectrometry generally is obtained through the programming that the trade marks offers to the client with the objective of the automatic calculation of the activity concentrations existing in a sample. In this report, the examples shown in the ISO 11929 standard are compared to the programming realised by Genie 2k for determining characteristic limits. The main difference of both is located in the uncertainty calculations due to the efficiency calibration that is considered by ISO and not by Genie 2K. Through implementation in the software developed by trade marks will be possible to introduce this uncertainty and to assimilate to the calculation done by ISO 11929. In the second part of this report will be analyzed the more complicated samples of this application as counting in a whole body counter (following ISO-28218 about Performance Criteria for radio bioassay), multiplet, overlapping, addition of several peaks for obtaining the activity concentration, etc. (Author) 19 refs.

  19. Study on the Effects of Sample Density on Gamma Spectrometry System Measurement Efficiency at Radiochemistry and Environment Laboratory

    International Nuclear Information System (INIS)

    Wo, Y.M.; Dainee Nor Fardzila Ahmad Tugi; Khairul Nizam Razali

    2015-01-01

    The effects of sample density on the measurement efficiency of the gamma spectrometry system were studied by using four sets multi nuclide standard sources of various densities between 0.3 - 1.4 g/ ml. The study was conducted on seven unit 25 % coaxial HPGe detector gamma spectrometry systems in Radiochemistry and Environment Laboratory (RAS). Difference on efficiency against gamma emitting radionuclides energy and measurement systems were compared and discussed. Correction factor for self absorption caused by difference in sample matrix density of the gamma systems were estimated. The correction factors are to be used in quantification of radionuclides concentration in various densities of service and research samples in RAS. (author)

  20. A rapid dissolution procedure to aid initial nuclear forensics investigations of chemically refractory compounds and particles prior to gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Reading, David G., E-mail: d.reading@noc.soton.ac.uk [GAU-Radioanalytical Laboratories, Ocean and Earth Science, University of Southampton, National Oceanography Centre, European Way, Southampton SO14 3ZH (United Kingdom); Croudace, Ian W.; Warwick, Phillip E. [GAU-Radioanalytical Laboratories, Ocean and Earth Science, University of Southampton, National Oceanography Centre, European Way, Southampton SO14 3ZH (United Kingdom); Britton, Richard [AWE plc, Aldermaston, Reading, Berkshire, RG7 4PR (United Kingdom)

    2015-11-05

    A rapid and effective preparative procedure has been evaluated for the accurate determination of low-energy (40–200 keV) gamma-emitting radionuclides ({sup 210}Pb, {sup 234}Th, {sup 226}Ra, {sup 235}U) in uranium ores and uranium ore concentrates (UOCs) using high-resolution gamma ray spectrometry. The measurement of low-energy gamma photons is complicated in heterogeneous samples containing high-density mineral phases and in such situations activity concentrations will be underestimated. This is because attenuation corrections, calculated based on sample mean density, do not properly correct where dense grains are dispersed within a less dense matrix (analogous to a nugget effect). The current method overcomes these problems using a lithium tetraborate fusion that readily dissolves all components including high-density, self-attenuating minerals/compounds. This is the ideal method for dissolving complex, non-volatile components in soils, rocks, mineral concentrates, and other materials where density reduction is required. Lithium borate fusion avoids the need for theoretical efficiency corrections or measurement of matrix matched calibration standards. The resulting homogeneous quenched glass produced can be quickly dissolved in nitric acid producing low-density solutions that can be counted by gamma spectrometry. The effectiveness of the technique is demonstrated using uranium-bearing Certified Reference Materials and provides accurate activity concentration determinations compared to the underestimated activity concentrations derived from direct measurements of a bulk sample. The procedure offers an effective solution for initial nuclear forensic studies where complex refractory minerals or matrices exist. It is also significantly faster, safer and simpler than alternative approaches. - Highlights: • Low energy gamma photons (<200 keV) are attenuated in U-bearing compounds. • Corrections based on bulk density do not yield accurate activity

  1. The metrological activity determination of 238 U and 230 Th by gamma spectrometry to industrial fuel-cycle application

    International Nuclear Information System (INIS)

    Almeida M, M.C. de; Delgado, J.U.; Poledna, R.

    2006-01-01

    This work describes the difficulty for determining the activity of 238 U and 230 Th using gamma spectrometry due to the low gamma-ray emission probabilities of 92 and 67 keV, and, mainly, the associated high uncertainties about 13 and 11%, respectively. 230 Th is a 238 U daughter and it is product from uranium mills and refineries. 230 Th decays to 226 Ra and this decay has to be measured because these radionuclides are not in secular equilibrium with their daughter products, besides the gamma-energies have high uncertainties in the emission probabilities. These radionuclides, mostly 238 U, are important in the nuclear fuel-cycle, since the mining of uranium ore, where the nominal isotopic content of natural uranium is 99.27% of 238 U, until the irradiated fuel reprocessing, where this isotope, a fertile material, is recovered to be used again. The uranium and thorium are considered safeguarded nuclear materials and the metrology tries to calibrate and standardize these materials to improve the activity determination techniques applied in different fuel-cycle scopes. The essential characteristics of the safeguarded materials are low gamma energies (less than 100 keV) and emission probabilities but with high uncertainties. In this way, the metrology can contribute to homeland security defense against illicit nuclear trafficking with the identification and quantification of the safeguarded radionuclides such as uranium and thorium, using specific gamma window energy and high resolution planar or coaxial germanium detector. The efficiency curve is obtained from the reference source spectrum considering the photopeak areas corresponding the standard activities. This curve depends on radiation energy, sample geometry, photon attenuation (sample absorption and material absorption between sample-detector), dead time and sample-detector position. The metrological activity determinations of 238 U solid sources, and of 230 Th, in solution (5 ml flask), were performed using

  2. High-Resolution Mass Spectrometers

    Science.gov (United States)

    Marshall, Alan G.; Hendrickson, Christopher L.

    2008-07-01

    Over the past decade, mass spectrometry has been revolutionized by access to instruments of increasingly high mass-resolving power. For small molecules up to ˜400 Da (e.g., drugs, metabolites, and various natural organic mixtures ranging from foods to petroleum), it is possible to determine elemental compositions (CcHhNnOoSsPp…) of thousands of chemical components simultaneously from accurate mass measurements (the same can be done up to 1000 Da if additional information is included). At higher mass, it becomes possible to identify proteins (including posttranslational modifications) from proteolytic peptides, as well as lipids, glycoconjugates, and other biological components. At even higher mass (˜100,000 Da or higher), it is possible to characterize posttranslational modifications of intact proteins and to map the binding surfaces of large biomolecule complexes. Here we review the principles and techniques of the highest-resolution analytical mass spectrometers (time-of-flight and Fourier transform ion cyclotron resonance and orbitrap mass analyzers) and describe some representative high-resolution applications.

  3. Demonstrating the European capability for airborne gamma spectrometry: results from the eccomags exercise

    International Nuclear Information System (INIS)

    Sanderson, D.C.W.

    2003-01-01

    Full text: Airborne gamma spectrometry has emerged over recent years as an important means for mapping deposited activity and dose-rates in the environment. Its importance to emergency response has been increasingly recognised in defining contaminated areas at rates of measurement and spatial density which simply cannot be matched using ground based methods. In Europe the practical capability for AGS has developed markedly over the period since the Chernobyl accident, and significant progress towards cooperation between AGS teams, and convergence of methodology has been made, largely as the result of work conducted with support from the Commission under Frameworks IV and V. As an important part of the ECCOMAGS project an international comparison was undertaken in SW Scotland in 2002 to evaluate the performance of AGS teams in comparison with established groundbased methods. The work included a composite mapping task whereby different AGS teams recorded data over adjacent areas, to demonstrate the potential for collective actions in emergency response. More than 70,000 observations were made from a 90x40 km area during a 3 day period by several European teams, and compiled within days to produce regional scale maps for 137-Cs contamination and environmental gamma dose-rates. In three disjoint common areas AGS and ground based observations were taken. The ground based work was split for practical reasons into two phases; a pre-characterization stage to define calibration sites, and a second stage where sampling of additional sites was undertake synchronously with the exercise to provide the basis for blind intercomparison with AGS. More than 800 laboratory gamma spectrometry measurements were taken in support of this activity, which in combination with in-situ gamma spectrometry and instrumental dose-rate measurements were used to define the ground-based estimates of 137-Cs activity per unit area and dose-rate. AGS for the common areas, included points for ground

  4. Results and comments on the gamma spectrometry examinations carried out on PWR and fast neutron fuel elements

    International Nuclear Information System (INIS)

    Pineira, Thomas; Mouchnino, Michel; Juste, Guy; Vignesoult, Nicole.

    1980-05-01

    The gamma spectrometry analyses on the fuel elements of PWR and fast neutron systems have experienced a significant growth in the CEA. This nondestructive, quick, inexpensive and quantitative method, seems to us particularly advantageous for qualifying the behavior of fuel under irradiation. However, in order to use it to the maximum, it must have reached a high degree of automation and the interpretation of the results must be the outcome of a coherent team that includes gamma spectrometry and fuel element specialists, since the growth of hot cell gamma spectrometry involves the processing of a considerable number of data upon which the quality of the results depends (large number of spectra per pencil analyzed, dimension of the 2000 or 4000 channel spectra, number of lines studied, etc.). Therefore the need to make the most of the information and, in particular, to present the results in a form suitable for direct processing in a minimum response time, requires a highly automated system. Further, the more specific results of gamma spectrometry correlated to the metallurgical results obtained in the laboratories should contribute efficiently to obtaining major information [fr

  5. Two low-level gamma spectrometry systems of the IAEA Safeguards Analytical Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Parus, J L [IAEA, SAL, Vienna (Austria); Raab, W [IAEA, SAL, Vienna (Austria); Donohue, D [IAEA, SAL, Vienna (Austria); Jansta, V [IAEA, SAL, Vienna (Austria); Kierzek, J [IAEA, SAL, Vienna (Austria)

    1997-03-01

    A gamma spectrometry system designed for the measurement of samples with low and medium radioactivity (activity from a few to about 10{sup 4} Bq in the energy range from 25 to 2700 keV) has been installed at the IAEA Safeguards Analytical Laboratory in Seibersdorf. The system consists of 3 low level detectors: (1) n-type coaxial Ge with 42.4% relative efficiency, 1.85 keV FWHM at 1.33 MeV (2) planar Ge with 2000 mm{sup 2} area and 20 mm thickness, 562 eV FWHM at 122 keV (3) NaI(Tl) annulus of 25.4 cm diameter and 25.4 cm height, hole diameter 90 mm. (orig./DG)

  6. Evaluation of the natural radioactivity using thermoluminescence, gamma spectrometry and neutron activation techniques

    International Nuclear Information System (INIS)

    Fausto, A.M.; Otsubo, S.M.; Paes, W.S.; Yoshimura, E.M.; Okuno, E.; Hiodo, F.; Marques, L.S.; Alcala, A.L.

    1996-01-01

    The evaluation of the radiation dose in the living species due to the natural radioactivity is the main objective of this paper. The region that had been monitored was Intrusive Suite of Itu near to Sao Paulo city. Lateral[and depth distributions of natural radioactivity of the soil were determined using the techniques of thermoluminescence gamma spectrometry and neutron[activation. From the concentration in the soil of K-40 and radioactive elements of U and Th series experimentally determined, the dose due to gamma rays in air at 1 m from the soil was evaluated and the results compared with the direct dose measured with the portable rate-meter. (authors). 11 refs., 3 figs

  7. Dating the age of a recent nuclear event by gamma-spectrometry

    International Nuclear Information System (INIS)

    Nir-El, Y.

    2006-01-01

    The age of a recent, i.e., fresh, nuclear event can be determined by measuring the activity of short-lived parent and daughter fission products. The event studied was a short irradiation, of a small sample of uranium, in a nuclear reactor. Two clocks were investigated, 92 Sr- 92 Y and 135 I- 135 Xe. Measurements of the source by gamma-spectrometry yielded very good agreement between true and measured ages. The upper and lower age limits of applicability for the clocks in question were defined. The half-life of 92 Sr was found 2.635±0.008 hours and of 135 I 6.65±0.04 hours. (author)

  8. Determination of Th and U by neutron activation for gamma spectrometry calibration in situ

    International Nuclear Information System (INIS)

    Nava M, F.; Rios M, C.; Mireles G, F.; Saucedo A, S.; Davila R, I.; Pinedo, J. L.; Landsberger, S.

    2012-10-01

    Using the analysis by neutron activation to determine the profile of the thorium and uranium concentration calibration factors were obtained for their use in the gamma spectrometry in situ. Three sites were selected (San Ramon, Villa de Cos y la Zacatecana) and the analysis by activation was development in the Laboratory of Nuclear Engineering Teaching of the Texas University in Austin with the nuclear reactor Ut-TRIGA. Starting from the gamma spectra in situ, the areas of normalized photo-pick of the radioisotopes were: 208 Tl and 228 Ac for the thorium series and 214 Pb and 214 Bi for the uranium series. The averages of the factors found in units of (cpm/Bq/Kg) are of 105.63±8.32 and 75.87±4.61 for the thorium and uranium, respectively. (Author)

  9. Determination of {sup 126}Sn half-life from ICP-MS and gamma spectrometry measurements

    Energy Technology Data Exchange (ETDEWEB)

    Bienvenu, P.; Arnal, N.; Comte, J. [CEA Cadarache DEN/DEC/SA3C/LARC, Paul Lez Durance (France); Ferreux, L.; Lepy, M.C.; Be, M.M. [CEA Saclay LIST LNE/LNHB, Gif sur Yvette (France); Andreoletti, G. [AREVA Cogema SL/UP2-800, Beaumont Hague (France)

    2009-07-01

    A new value of {sup 126}Sn half-life was determined by combination of inductively coupled plasma-mass spectrometry (ICP-MS) and gamma spectrometry measurements on purified sample solutions collected from nuclear fuel reprocessing. {sup 126}Sn was isolated through dissolution of fission product precipitates and liquid-liquid extraction with N-benzoyl-N-phenyl-hydroxylamine (BPHA). The abundance of {sup 126}Sn atoms together with the absence of interfering species in the analysed solutions made it possible to measure both mass concentration and nuclide activity with high precision and accuracy. This led to a {sup 126}Sn half-life value of 1.980 (57) x 10{sup 5} a. (orig.)

  10. Validation of Cs-137 measurement in food samples using gamma spectrometry system

    International Nuclear Information System (INIS)

    Yii Mei Wo; Kamarozaman Ishak

    2005-01-01

    Cs-137 was found to be one of major radionuclide contaminant present in foods consumed by human. In some countries, regulations required consumption foods moving in international trade to be scanned for caesium (Cs-134 and Cs-137) to ensure it does not exceeding the maximum permissible level. This is to ensure that the intake of such foods will not accumulate radionuclide until the significant level inside the human body. Gamma Spectrometry System was used to perform the measurement of caesium isotopes, because it was one of the easiest methods to be performed. This measuring method must be validated for several parameters include specificity, precision (repeatability), bias (accuracy), linearity, range, detection limit, robustness and ruggedness in order to ensure it is fit for the purpose. This paper would summarise how these parameters were fulfilled for this analytical method using several types certified reference materials. The same validated method would be considered workable on Cs-134 as well. (Author)

  11. Comparative study of the gamma spectrometry method performance in different measurement geometries

    International Nuclear Information System (INIS)

    Diaconescu, C.; Ichim, C.; Bujoreanu, L.; Florea, I.

    2013-01-01

    This paper presents the results obtained by gamma spectrometry on aqueous liquid waste sample using different measurement geometries. A liquid waste sample with known gamma emitters content was measured in three different geometries in order to assess the influence of the geometry on the final results. To obtain low measurement errors, gamma spectrometer was calibrated using a calibration standard with the same physical and chemical characteristics as the sample to be measured. Since the calibration was performed with the source at contact with HPGe detector, the waste sample was also measured, for all the three geometries, at the detector contact. The influence of the measurement geometry on the results was evaluated by computing the relative errors. The measurements performed using three different geometries (250 ml plastic vial, Sarpagan box and 24 ml Tricarb vial) showed that all these geometries may be used to quantify the activity of gamma emitters in different type of radioactive waste. (authors)

  12. Study of the parabolic-spherical shape on the energy resolution in gamma spectrometry

    International Nuclear Information System (INIS)

    Silva, Joao Carlos Pereira da

    1997-01-01

    In gamma spectrometry, the energy resolution is an important parameter. This parameter measures the capability of the system to separate two photopeaks that are together. Scintillation systems have various factors that affect the energy resolution: energy deposition, light emission, light collection and electric signal processing. Light collection depended on the mechanisms of light transport until light strikes on the photocathode. In this trajectory the light losses energy by attenuation and refractions on the surfaces. In order to minimize these effects, a parabolic-spherical shape is proposed. The energy resolutions of hemispherical and parabolic-spherical shapes were measured. The results show a better resolution for the new shape, about 33% for Compton edge due to a 137 Cs radioactive source. (author)

  13. The use of difference spectra with a filtered rolling average background in mobile gamma spectrometry measurements

    International Nuclear Information System (INIS)

    Cresswell, A.J.; Sanderson, D.C.W.

    2009-01-01

    The use of difference spectra, with a filtering of a rolling average background, as a variation of the more common rainbow plots to aid in the visual identification of radiation anomalies in mobile gamma spectrometry systems is presented. This method requires minimal assumptions about the radiation environment, and is not computationally intensive. Some case studies are presented to illustrate the method. It is shown that difference spectra produced in this manner can improve signal to background, estimate shielding or mass depth using scattered spectral components, and locate point sources. This approach could be a useful addition to the methods available for locating point sources and mapping dispersed activity in real time. Further possible developments of the procedure utilising more intelligent filters and spatial averaging of the background are identified.

  14. Programmer for automatic gamma spectrometry; Ordonnateur de sequence pour spectrometrie gamma automatique

    Energy Technology Data Exchange (ETDEWEB)

    Romanetti, R [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1968-04-01

    With this apparatus, which is constructed of logical integrated circuits, it is possible both to synchronize an automatic gamma spectrometry assembly and to record the spectra on punched cards. An IBM terminal will make it possible with the help of analysis by the least squares method and by a direct dialogue with an IBM 360 computer to obtain analytical results almost instantaneously. (author) [French] Cet appareil, realise en circuits integres logiques, permet d'une part de synchroniser un ensemble automatique de spectrometrie gamma et d'autre part d'enregistrer les spectres sur cartes perforees. Un terminal IBM permettra, a l'aide d'un programme d'analyse par la methode des moindres carres et par un dialogue direct avec un ordinateur IBM 360, de disposer presque intanstanement des resultats des analyses. (auteur)

  15. Optimization of measurement geometries used by the C.I.R. 'Gamma Spectrometry' working group

    International Nuclear Information System (INIS)

    Escarieux, M.

    1979-01-01

    The choice of measurement geometry is closely tied to the objective sought in gamma quantitative analysis which consists in identifying the radionuclides present in a sample and in determining the voluminal quantities. The too low efficiency of the detector and the levels of activity sought make it necessary to place the sample in contact with the casing of the detector and select a sample geometry suited to the measurement. In point of fact this choice is often determined by other criteria, availability of the container for example, and this leads the laboratories taking part in the 'Gamma Spectrometry' Working Group of the Comite d'Instrumentation de Radioprotection to adopt joint gamma measurement geometries [fr

  16. Determination of the self-attenuation correction factor for environmental samples analysis in gamma spectrometry

    International Nuclear Information System (INIS)

    Santos, Talita O.; Rocha, Zildete; Knupp, Eliana A.N.; Kastner, Geraldo F.; Oliveira, Arno H. de; Oliveira, Arno H. de

    2015-01-01

    Gamma spectrometry technique has been used in order to obtain the activity concentrations of natural and artificial radionuclides in environmental samples of different origins, compositions and densities. These samples characteristics may influence the calibration condition by the self-attenuation effect. The sample density has been considered the most important factor. For reliable results, it is necessary to determine self-attenuation correction factor which has been subject of great interest due to its effect on activity concentration. In this context, the aim of this work is to show the calibration process considering the correction by self-attenuation in the evaluation of the concentration of each radionuclide to a gamma HPGEe detector spectrometry system. (author)

  17. The use of gamma spectrometry in mapping alteration zones in Olkiluoto

    International Nuclear Information System (INIS)

    Ojala, J.V.; Turunen, P.; Eilu, P.; Julkunen, A.; Gehoer, S.

    2007-08-01

    In the Olkiluoto site, a detailed gammaspectrometry log from the drill hole OL-KR27 was used to estimate the concentrations of K, Th and U. The gamma spectrometry results, lithological variations, and kaolinite and illite alteration visually mapped from the drill hole were compared. The result indicate that the Th/K ratio correlates best with lithology and that, in most cases, the changes in the ratio indicate lithological contacts and rising or falling trends of Th/K ratio with some peaks have some correlation with the kaolinite-illite alteration. From the result it is suggested that that very variable Th/K ratio is a reasonably good indicator of alteration zones even in the migmatic gneiss area in the Olkiluoto site. (orig.)

  18. Validation of Am-241 measurement in ion chamber type smoke detector by using gamma spectrometry system

    International Nuclear Information System (INIS)

    Yii Mei Wo; Khairul Nizam Razali

    2005-01-01

    Smoke detectors are useful devices in modern days that able to save many lives. Even though, the use of ion chamber type smoke detector (usually contain Americium-241) was exempted in Malaysia, but the trading of this device was controlled by regulation, under the Atomic Energy Licensing Act (Act 304). The activity of the Am-241 can be measured by using the Gamma Spectrometry System since it was much easier, compared to Alpha Spectrometry System. To do so, the system was first need to be calibrated using the standard reference source to find the efficiency of the germanium detector. The method used for the measurement was first validated for several relevant parameters, which include specificity, precision (repeatability), bias (accuracy), linearity, working range, detection limit, robustness and ruggedness to ensure it was fit for the purpose. The measured Am-241 activity inside the smoke detector will be reported together with a reasonable expanded uncertainty arise from the measurement. (Author)

  19. Fully automated gamma spectrometry gauge observing possible radioactive contamination of melting-shop samples

    International Nuclear Information System (INIS)

    Kroos, J.; Westkaemper, G.; Stein, J.

    1999-01-01

    At Salzgitter AG, several monitoring systems have been installed to check the scrap transport by rail and by car. At the moment, the scrap transport by ship is reloaded onto wagons for monitoring afterwards. In the future, a detection system will be mounted onto a crane for a direct check on scrap upon the departure of ship. Furthermore, at Salzgitter AG Central Chemical Laboratory, a fully automated gamma spectrometry gauge is installed in order to observe a possible radioactive contamination of the products. The gamma spectrometer is integrated into the automated OE spectrometry line for testing melting shop samples after performing the OE spectrometry. With this technique the specific activity of selected nuclides and dose rate will be determined. The activity observation is part of the release procedure. The corresponding measurement data are stored in a database for quality management reasons. (author)

  20. Low-energy X-ray and gamma spectrometry using silicon photodiodes

    International Nuclear Information System (INIS)

    Silva, Iran Jose Oliveira da

    2000-08-01

    The use of semiconductor detectors for radiation detection has increased in recent years due to advantages they present in comparison to other types of detectors. As the working principle of commercially available photodiodes is similar to the semiconductor detector, this study was carried out to evaluate the use of Si photodiodes for low energy x-ray and gamma spectrometry. The photodiodes investigated were SFH-205, SFH-206, BPW-34 and XRA-50 which have the following characteristics: active area of 0,07 cm 2 and 0,25 cm 2 , thickness of the depletion ranging from 100 to 200 μm and junction capacitance of 72 pF. The photodiode was polarized with a reverse bias and connected to a charge sensitive pre-amplifier, followed by a amplifier and multichannel pulse analyzer. Standard radiation source used in this experiment were 241 Am, 109 Cd, 57 Co and 133 Ba. The X-ray fluorescence of lead and silver were also measured through K- and L-lines. All the measurements were made with the photodiodes at room temperature.The results show that the responses of the photodiodes very linear by the x-ray energy and that the energy resolution in FWHM varied between 1.9 keV and 4.4 keV for peaks corresponding to 11.9 keV to 59 keV. The BPW-34 showed the best energy resolution and the lower dark current. The full-energy peak efficiency was also determined and it was observed that the peak efficiency decreases rapidly above 50 keV. The resolution and efficiency are similar to the values obtained with other semiconductor detectors, evidencing that the photodiodes used in that study can be used as a good performance detector for low energy X-ray and gamma spectrometry. (author)

  1. High-resolution intravital microscopy.

    Directory of Open Access Journals (Sweden)

    Volker Andresen

    Full Text Available Cellular communication constitutes a fundamental mechanism of life, for instance by permitting transfer of information through synapses in the nervous system and by leading to activation of cells during the course of immune responses. Monitoring cell-cell interactions within living adult organisms is crucial in order to draw conclusions on their behavior with respect to the fate of cells, tissues and organs. Until now, there is no technology available that enables dynamic imaging deep within the tissue of living adult organisms at sub-cellular resolution, i.e. detection at the level of few protein molecules. Here we present a novel approach called multi-beam striped-illumination which applies for the first time the principle and advantages of structured-illumination, spatial modulation of the excitation pattern, to laser-scanning-microscopy. We use this approach in two-photon-microscopy--the most adequate optical deep-tissue imaging-technique. As compared to standard two-photon-microscopy, it achieves significant contrast enhancement and up to 3-fold improved axial resolution (optical sectioning while photobleaching, photodamage and acquisition speed are similar. Its imaging depth is comparable to multifocal two-photon-microscopy and only slightly less than in standard single-beam two-photon-microscopy. Precisely, our studies within mouse lymph nodes demonstrated 216% improved axial and 23% improved lateral resolutions at a depth of 80 µm below the surface. Thus, we are for the first time able to visualize the dynamic interactions between B cells and immune complex deposits on follicular dendritic cells within germinal centers (GCs of live mice. These interactions play a decisive role in the process of clonal selection, leading to affinity maturation of the humoral immune response. This novel high-resolution intravital microscopy method has a huge potential for numerous applications in neurosciences, immunology, cancer research and

  2. High-Resolution Intravital Microscopy

    Science.gov (United States)

    Andresen, Volker; Pollok, Karolin; Rinnenthal, Jan-Leo; Oehme, Laura; Günther, Robert; Spiecker, Heinrich; Radbruch, Helena; Gerhard, Jenny; Sporbert, Anje; Cseresnyes, Zoltan; Hauser, Anja E.; Niesner, Raluca

    2012-01-01

    Cellular communication constitutes a fundamental mechanism of life, for instance by permitting transfer of information through synapses in the nervous system and by leading to activation of cells during the course of immune responses. Monitoring cell-cell interactions within living adult organisms is crucial in order to draw conclusions on their behavior with respect to the fate of cells, tissues and organs. Until now, there is no technology available that enables dynamic imaging deep within the tissue of living adult organisms at sub-cellular resolution, i.e. detection at the level of few protein molecules. Here we present a novel approach called multi-beam striped-illumination which applies for the first time the principle and advantages of structured-illumination, spatial modulation of the excitation pattern, to laser-scanning-microscopy. We use this approach in two-photon-microscopy - the most adequate optical deep-tissue imaging-technique. As compared to standard two-photon-microscopy, it achieves significant contrast enhancement and up to 3-fold improved axial resolution (optical sectioning) while photobleaching, photodamage and acquisition speed are similar. Its imaging depth is comparable to multifocal two-photon-microscopy and only slightly less than in standard single-beam two-photon-microscopy. Precisely, our studies within mouse lymph nodes demonstrated 216% improved axial and 23% improved lateral resolutions at a depth of 80 µm below the surface. Thus, we are for the first time able to visualize the dynamic interactions between B cells and immune complex deposits on follicular dendritic cells within germinal centers (GCs) of live mice. These interactions play a decisive role in the process of clonal selection, leading to affinity maturation of the humoral immune response. This novel high-resolution intravital microscopy method has a huge potential for numerous applications in neurosciences, immunology, cancer research and developmental biology

  3. Section on High Resolution Optical Imaging (HROI)

    Data.gov (United States)

    Federal Laboratory Consortium — The Section on High Resolution Optical Imaging (HROI) develops novel technologies for studying biological processes at unprecedented speed and resolution. Research...

  4. Development of AMS high resolution injector system

    International Nuclear Information System (INIS)

    Bao Yiwen; Guan Xialing; Hu Yueming

    2008-01-01

    The Beijing HI-13 tandem accelerator AMS high resolution injector system was developed. The high resolution energy achromatic system consists of an electrostatic analyzer and a magnetic analyzer, which mass resolution can reach 600 and transmission is better than 80%. (authors)

  5. Assessment of calibration parameters for an aerial gamma spectrometry system using Monte-Carlo technique

    International Nuclear Information System (INIS)

    Srinivasan, P.; Raman, Anand; Sharma, D.N.

    2009-01-01

    Aerial gamma spectrometry is a very effective method for quickly surveying a large area, which might get contaminated following a nuclear accident, or due to nuclear weapon fallout. The technique not only helps in identifying the contaminating radionuclide but also in assessing the magnitude and the extent of contamination. These two factors are of importance for the authorities to quickly plan and execute effective counter measures and controls if required. The development of Airborne gamma ray spectrometry systems have been reported by different institutions. The application of these systems have been reported by different authors. Radiation Safety Systems Division of the Bhabha Atomic Research Centre has developed an Aerial Gamma Spectrometry System (AGSS) and the surveying methodology. For an online assessment of the contamination levels, it is essential to calibrate the system (AGSS) either flying it over a known contaminated area or over a simulated contaminated surface by deploying sealed sources on the ground. AGSS has been calibrated for different detectors in aerial exercises using such simulated contamination on the ground. The calibration methodology essentially needs net photo-peak counts in selected energy windows to finally arrive at the Air to Ground Correlation Factors at selected flight parameters such as altitude, speed of flight and the time interval at which each spectrum is acquired. This paper describes the methodology to predict all the necessary parameters like photon fluence at various altitudes, the photo-peak counts in different energy windows, Air to Ground Correlation Factors(AGCF), the dose rate at any height due to air scattered gamma ray photons etc. These parameters are predicted for a given source deployment matrix, detector and altitude of flying using the Monte-Carlo code MCNP (Monte Carlo Neutron and Photon Transport Code.CCC-200, RSIC, ORNL, Tennessee, USA). A methodology to generate the completely folded gamma ray count

  6. Efficiency transfer using the GEANT4 code of CERN for HPGe gamma spectrometry

    International Nuclear Information System (INIS)

    Chagren, S.; Tekaya, M.Ben; Reguigui, N.; Gharbi, F.

    2016-01-01

    In this work we apply the GEANT4 code of CERN to calculate the peak efficiency in High Pure Germanium (HPGe) gamma spectrometry using three different procedures. The first is a direct calculation. The second corresponds to the usual case of efficiency transfer between two different configurations at constant emission energy assuming a reference point detection configuration and the third, a new procedure, consists on the transfer of the peak efficiency between two detection configurations emitting the gamma ray in different energies assuming a “virtual” reference point detection configuration. No pre-optimization of the detector geometrical characteristics was performed before the transfer to test the ability of the efficiency transfer to reduce the effect of the ignorance on their real magnitude on the quality of the transferred efficiency. The obtained and measured efficiencies were found in good agreement for the two investigated methods of efficiency transfer. The obtained agreement proves that Monte Carlo method and especially the GEANT4 code constitute an efficient tool to obtain accurate detection efficiency values. The second investigated efficiency transfer procedure is useful to calibrate the HPGe gamma detector for any emission energy value for a voluminous source using one point source detection efficiency emitting in a different energy as a reference efficiency. The calculations preformed in this work were applied to the measurement exercise of the EUROMET428 project. A measurement exercise where an evaluation of the full energy peak efficiencies in the energy range 60–2000 keV for a typical coaxial p-type HpGe detector and several types of source configuration: point sources located at various distances from the detector and a cylindrical box containing three matrices was performed. - Highlights: • The GEANT4 code of CERN has been used to transfer the peak efficiency from point to points and voluminous detection configurations in HPGe gamma

  7. A Comparison between HPGe and NaI(Tl) detectors performance for gamma-spectrometry of low level measurement

    International Nuclear Information System (INIS)

    Poursiamy, N. H.; Tajikahmadi, H.; Mirshojaei, S. F.

    2005-01-01

    According to progressive usage of nuclear technology, it's important to prevent the contamination of the environment by man-made radioisotopes and exposures of human being. Radioisotopes can enter the human body by inhalation and ingestion which are the most important ways to internal exposures. Measurement of radiation level in foodstuff is one of the most important parameters in environmental safety which is performed according to constitution and standard tests in most countries such as Iran. Gamma spectrometry is carried out by NaI(Tl) and HPGe detector systems for foodstuffs. In this research operation of HPGe and NaI(Tl) detectors in gamma spectrometry with a standard radioactive source are investigated and compared. Also the result of NaI superiority in foodstuff radiation measurement given

  8. Metrological characterization of the numerical system Adonis for gamma spectrometry; Caracterisation metrologique du systeme de spectrometrie gamma numerique Adonis

    Energy Technology Data Exchange (ETDEWEB)

    Plagnard, J.; Morel, J.; Tran Tuan, A

    2005-07-01

    In gamma spectrometry, new acquisition systems based on digital processing of the signals are now available on the market. In order to determine their performances at high count rates, The CEA-LNHB (Commissariat a l'Energie Atomique - Laboratoire National Henri Becquerel) has tested several of these equipments.. These tests have clearly shown that the performances announced by the manufacturers were generally not met. At this point, it was interesting to include in these tests, the system ADONIS (Atelier de Developpement Numerique pour l'Instrumentation en Spectrometrie), which is the new gamma spectrometry system, developed by the CEA-SIAR (Service d'Instrumentation et d'Application des Rayonnements). (authors)

  9. Extraction of gold and mercury from sea water with bismuth diethyldithiocarbamate prior to neutron activation-. gamma. -spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yu, J.C.; Lo, J.M.; Wai, C.M. (Idaho Univ. Moscow (USA). Dept. of Chemistry)

    1983-11-01

    Gold and mercury in sea water can be selectively extracted by bismuth diethyldithiocarbamate into chloroform at pH <= 1. The matrix species and many other trace elements in the system are effectively removed during extraction. When neutron activation-..gamma..-spectrometry is used, the detection limits for gold and mercury are 0.001 and 0.01 ..mu..g l/sup -1/, respectively. The relative precision is 9% for gold and 13% for mercury.

  10. Development and calibration automatic equipment's measuring in real time of the environmental radioactivity by gamma spectrometry

    International Nuclear Information System (INIS)

    Casanovas, R.; Morant, J. J.; Salvado, M.

    2013-01-01

    In this paper, we describe the general aspects of the implementation of gamma spectrometry in water, as well as the development of two measuring devices based on this technique: aerosol monitor (RARM-F) and a monitor direct measurement (RARMD2) , both patent applications. Furthermore, they described in detail the aspects of calibration of equipment, which has been made by combining experimental measurements with Monte Carlo simulations. (Author)

  11. Determination Performance Of Gamma Spectrometry Co-Axial HPGE Detector In Radiochemistry And Environment Group, Nuclear Malaysia

    International Nuclear Information System (INIS)

    Mei-Woo, Y.

    2014-01-01

    Gamma Spectrometry System is used to measure qualitatively and quantitatively a gamma emitting radionuclide. The accuracy of the measurement very much depends on the performance specifications of the HPGe detectors. From this study it found that all the seven co-axial HPGe detectors in Radiochemistry and Environment Group, Nuclear Malaysia are in good working conditions base on the verification of performance specifications namely Resolution, Peak Shape, Peak-to-Compton ratio and Relative Efficiency against the warranted value from the manufacturers. (author)

  12. Survey of the 137Cs contamination in Belgium by in-situ gamma spectrometry, a decade after the Chernobyl accident.

    Science.gov (United States)

    Uyttenhove, J; Pommé, S; Van Waeyenberge, B; Hardeman, F; Buysse, J; Culot, J P

    1997-10-01

    The residual radiocesium concentration, nearly 10 y after the Chernobyl accident, is measured at different sites on the Belgian territory by means of in-situ gamma-spectrometry. A possible link between the rainfall at the beginning of May 1986 and the actual cesium concentration is investigated. The radiological impact of this contamination, even in the most affected regions in the Ardennes, is very small (<6 microSv y(-1)).

  13. Application of high resolution x-ray spectrometry preceded by neutron activation for elemental analysis of soil samples

    International Nuclear Information System (INIS)

    Hernandez Rivero, A.; Capote Rodriguez, G.; Padilla Alvarez, R.; Herrera Peraza, E.

    1997-01-01

    Utilization of High Resolution X-Ray Spectrometry preceded by activation of the samples by irradiation with neutron fluxes (NAA-RX) is a relatively modern trend in application of nuclear techniques. This method may complement advantageously the usual Neutron Activation Analysis by means of Gamma Spectrometry (NAA-G). In this work results obtained by the application of NAA-RX for non-destructive analysis of Cuban soil samples are discussed. The samples were irradiated with reactor neutron fluxes and the induced characteristic X-rays were measured by using Si(Li)-detector. Concentrations of Fe, Zn and Eu as determined by NAA-RX are compared with both NAA-G and XRF data. For the elaboration of X-Ray and Gamma Spectra the computer programs AXIL and ACTAN were used respectively. (author) [es

  14. Application of high resolution x-ray spectrometry preceded by neutron activation for elemental analysis of soil samples

    International Nuclear Information System (INIS)

    Hernandez Rivero, A.; Capote Rodriguez, G.; Herrera Peraza, E.

    1996-01-01

    Utilization of High Resolution X-Ray Spectrometry preceded by activation of the samples by irradiation with neutron fluxes (NAA R X) is a relatively modern trend in application of nuclear techniques. This method may complement advantageously the usual Neutron Activation Analysis by means of Gamma Spectrometry (NAA-G) In this work results obtained by the application of NAA-RX for non-destructive analysis of Cuban soil samples are discussed. The samples were irradiated with reactor neutron fluxes and the induced characteristic X-rays were measured by using Si(li)-detector. Concentrations of Fe, Zn and Eu as determined by NAA-RX are compared with both NAA-G and XRF data. For the elaboration of X-ray and Gamma Spectra the computer programs AXIL and ACTAN were used respectively

  15. Determination of burnup for IEAR-1 fuel elements by non destructive method of gamma spectrometry

    International Nuclear Information System (INIS)

    Madi Filho, T.; Holland, L.

    1982-01-01

    Burnup determination, by non-destructive gamma spectrometry of spent fuel with high and low activity of IEAR-1 reactor, using Cs-137 as burnup monitor, were done. To measure the Cs-137 distribution in these elements a Ge(Li) detector, with volume equal to 73,7 cm 3 , in two measurement systems with defined geometry and good colimation, was used. The IEA-14 taken from the core about 20 years ago, presents a gamma spectra due to Cs-137. The IEA-80, with cooling time approximately to 5 years, shows a more complex gamma spectrum due to other fission products still found in significant quantities. The IEA-14 measures were done in a measurement system used outside the reactor pool (S.I.), being the global efficiency of this system obtained by using a plane, calibrated and extense Ag-110 m source. Detailed measures of gamma transmission, using Cs-137 as a calibrated and punctiforme source, showed the high homogenity of the fuel plates. (E.G.) [pt

  16. Characterization of radioactive orphan sources by gamma spectrometry; Caracterizacion de fuentes huerfanas radiactivas por espectrometria gamma

    Energy Technology Data Exchange (ETDEWEB)

    Cruz W, H., E-mail: wcruz@ipen.gob.pe [Instituto Peruano de Energia Nuclear (PGRR/IPEN), Lima (Peru). Planta de Gestion de Residuos Radiactivos

    2013-07-01

    The sealed radioactive sources are widely applicable in industry. They must have a permanent control and must be registered with the Technical Office of the National Authority (OTAN). However, at times it has identified the presence of abandoned sealed sources unknown to the owner. These sources are called 'orphan sources'. Of course these sources represent a high potential risk because accidents can trigger dire consequences depending on your activity and chemical form in which it presents the radioisotope. This paper describes the process and the actions taken to characterize two orphan radioactive sources from the smelter a Aceros Arequipa. For characterization we used a gamma spectrometry system using a detector NaI(Tl) 3″ x 3″ with a multichannel analyzer Nucleus PCA-II. The radioisotope identified was cesium - 137 ({sup 137}Cs) in both cases. Fortunately, the sources maintained their integrity would otherwise have generated significant pollution considering the chemical form of the radioisotope and easy dispersion. (author)

  17. Gamma Spectrometry Analysis of Different Brands of Cement used in Nigeria

    International Nuclear Information System (INIS)

    Olarinoye, I.O.; Baba-Kutigi, A.N.; Sharifat, I.; Kolo, M.T.

    2014-01-01

    The natural radionuclide content of common brands of cement consumed in Nigeria is presented in this work. Samples of 9 brands of grey ordinary Portland cement (OPC) and 5 brands of white cement were collected and analyzed for their radiological content by gamma spectrometry using a 7.6 x 7.6 NaI(TI) detector. The total average content of 226 Ra, 232 Th and 40 k for all the cement brand samples were 38.1, 27.9 and 301.1 Bq/kg respectively and are lower when compared to the world average (50, 50 and 500 Bq/Kg) in building materials. The evaluated radium equivalent activities, external and internal indices were lower than the recommended safe limit and are comparable with result from similar studies concluded in other countries. The evaluation mean gonadal dose of equivalents of two cement brand samples were found to be higher than the world average in soil while others are less than the world average in soil.

  18. Burn-up measurements of spent fuel using gamma spectrometry technique

    International Nuclear Information System (INIS)

    Pereda, C.; Henriquez, C.; Klein, J.; Medel, J.

    2005-01-01

    Burn-up results obtained for HEU (45% of 235 U) fuel assemblies of the RECH-1 Research Reactor using gamma spectrometry technique are presented. The spectra were got from an in-pool facility built in the reactor to be mainly used to measure the burnup of irradiated fuel assemblies with short cooling time, where 95 Zr is being evaluated as possible fission monitor. A program to measure all spent fuel assemblies of the RECH-1 reactor was initiated in the frame of the Regional Project RLA/4/018: 'Management of Spent Fuel from Research Reactors'. The results presented here were obtained from HEU spent fuel assemblies with cooling time greater than 100 days and 137 Cs was used as fission monitor. The efficiency of the in-pool system was determined using a slightly burnt experimental fuel assembly, which has one fuel plate (one of the outer plates) and the rest are dummy plates. An average burn-up of 2.8% of 235 U was previously measured for the experimental fuel assembly utilizing a facility installed in a hot cell and 137 Cs was used as monitor. (author)

  19. Critical review of gamma spectrometry detection approaches for in-plant surface deposition monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Gregorich, Carola [Nuclear Fuels and Chemistry at the Electric Power Research Institute, Palo Alto, CA 94304, (United States)

    2015-07-01

    Surface deposition of activated corrosion product on oxide layers of light-water reactor primary system components is the primary source for ex-core radiation fields and personnel radiation exposure. Understanding the deposition mechanism and what factors influence the deposition and release behaviors are crucial for developing effective radiation field reduction measures. One of the available tools to assess the surface deposition is in-plant gamma spectrometry, which has been performed for several decades using either sodium iodide (NaI) or high-purity germanium (HPGe) detectors. Lately, the much more mobile cadmium-zinc-telluride (CZT) detectors are increasingly employed by stations because of their ease in use and handling. However, all of these gamma detectors face the same challenges; namely large-geometry samples of inconsistent sample compositions and sometimes gaps in the information necessary to establish proper efficiency calibrations. This paper reviews current measurements and efficiency calibration approaches taken in the industry. The validity of the measurement results and the feasibility of the data's use in understanding source term behavior is examined. Suggestions are made for the development of a more robust deposit characterization and radiation field monitoring program. (authors)

  20. The {sup 124}Sb activity standardization by gamma spectrometry for medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, M.C.M. de, E-mail: marcandida@yahoo.com.b [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes, Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear (SEMRA/LNMRI/IRD/CNEN), Av. Salvador Allende s/n, Recreio, Rio de Janeiro, RJ, CEP 22780-160 (Brazil); Iwahara, A.; Delgado, J.U.; Poledna, R.; Silva, R.L. da [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes, Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear (SEMRA/LNMRI/IRD/CNEN), Av. Salvador Allende s/n, Recreio, Rio de Janeiro, RJ, CEP 22780-160 (Brazil)

    2010-07-21

    This work describes a metrological activity determination of {sup 124}Sb, which can be used as radiotracer, applying gamma spectrometry methods with hyper pure germanium detector and efficiency curves. This isotope with good activity and high radionuclidic purity is employed in the form of meglumine antimoniate (Glucantime) or sodium stibogluconate (Pentostam) to treat leishmaniasis. {sup 124}Sb is also applied in animal organ distribution studies to solve some questions in pharmacology. {sup 124}Sb decays by {beta}-emission and it produces several photons (X and gamma rays) with energy varying from 27 to 2700 keV. Efficiency curves to measure point {sup 124}Sb solid sources were obtained from a {sup 166m}Ho standard that is a multi-gamma reference source. These curves depend on radiation energy, sample geometry, photon attenuation, dead time and sample-detector position. Results for activity determination of {sup 124}Sb samples using efficiency curves and a high purity coaxial germanium detector were consistent in different counting geometries. Also uncertainties of about 2% (k=2) were obtained.

  1. Report of the Department of Energy, Office of Environmental Management, Gamma Spectrometry Data Validation Program

    International Nuclear Information System (INIS)

    Decker, K.; Sanderson, C.G.; Greenlaw, P.

    1996-11-01

    This report represents the results of analyses received on or before August 15, 1996 for the first annual Gamma Spectrometry Data Validation Program (May 1996) designed to assess the capability of DOE laboratories and DOE contractors in performing routine gamma spectra analyses. Data reduction of gamma spectra are normally performed with computer codes supplied by commercial manufacturers or are developed in house. Earlier evaluations of commercial codes gave spurious results for complex spectrum. A calibration spectrum, a background spectrum and three sample spectra of increasing complexity were included for each format. The calibration spectrum contained nuclides covering the energy range from 59.5 keV to 1836 keV. The first two samples contained fallout nuclides with halflives of over 30 days. Naturally occurring nuclides were also present. The third sample contained both short and long lived fission product nuclides. The participants were asked to report values and uncertainties as Becquerel per sample with no decay correction. Sixteen software packages were evaluated. In general, the results do not appear to be dependent on the software used. Based on the control limits established for the Program for the three sample spectra, 62%, 63% and 53%, respectively, of the reported results were evaluated as acceptable

  2. Detection and evaluation of uranium in different minerals by gamma spectrometry and laser induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    Sergani, F.M.; Khedr, M.A.; Harith, M.A.; El Mongy, S.A.

    2004-01-01

    Analysis, detection and evaluation of source nuclear materials (e.g. uranium) in different minerals by sensitive techniques are a vital objective for uranium exploration, nuclear materials extraction, processing and verification. In this work, uranium in different geological formations was determined using gamma spectrometry and laser induced breakdown spectroscopy (LIBS). The investigated samples were collected from different regions distributed all over Egypt. The samples were then prepared for non-destructive analysis. A hyper pure germanium detector was used to measure the emitted gamma rays of uranium and its daughters in the samples. The concentrations of uranium in ppm (μg/g) in the investigated samples are given and discussed in this work. The highest uranium concentration (4354.9 ppm) was found in uranophane samples of Gattar rocks. In Laser induced breakdown spectroscopy (LIBS) technique, plasma was formed by irradiating the rock surface with focused Q-switched Nd:Yag laser pulses of 7 ns pulse duration at the fundamental wavelength (1064 nm). Atoms and ions originating from the rock surface are excited and ionized in the laser produced hot plasma (∝10 000 K). The plasma emission spectral line is characteristic of the elements present in the plasma and allows identification of the uranium in the uranophane mineral. The strong atomic line at 424.2 nm is used for the qualitative identification of uranium. It can be mentioned that the elevated levels of uranium in some of the investigated uranophane samples are of great economic feasibility to be extracted. (orig.)

  3. Development and application of portable mobile gamma spectrometry system (PMGSS) for realtime online radiological assessment

    International Nuclear Information System (INIS)

    Patil, S.S.; Padmanabhan, N.; Sharma, R.; Singh, R.; Pradeepkumar, K.S.

    2008-01-01

    A state of art mobile monitoring system is a prime requirement to combat the challenging radiological situations. In the event of any radiological/nuclear Emergencies an effective, realistic methodology of radiological measurements is an asset. In this context, a highly sensitive real-time online mobile monitoring system having features and provision to display the important parameters will be an essential tool in the course of radiological impact assessment. This paper, describes the efforts that has been made towards providing a useful Portable Mobile Gamma Spectrometry System (PMGSS) and developing applications so as to enhance its usefulness in quick radiological impact assessment and to initiate the proper countermeasures during any Nuclear/Radiological emergency situation in public domain. The system uses a NaI(Tl) detector, a global positioning system (GPS) and a laptop PC for storage, analysis and graphical representation of the acquired data. PMGSS is a highly sensitive, portable and reliable radiation monitoring equipment with capability of qualitative and quick estimation of the radioisotopes. The system was used for the mobile radiological mapping of Bangalore and Mumbai city and demonstrated its capability for use in environmental radiation monitoring during any radiological emergency requirement the results of which are presented here. (abstract)

  4. Calibration of a Gamma Spectrometry System Used for the Determination of Cs-137 in Spanish Soils

    International Nuclear Information System (INIS)

    Barreraa, M.; Romero, M. L.; Valino, F.

    2008-01-01

    The document describes the methodology used at CIEMAT in order to determine, by gamma spectrometry, the background levels of the radionuclide Cs-137 in soils of the Spanish peninsular territory. the work is a part of an extensive research project developed jointly by the University of the Basque Country (UPV-EHU) and the CIEMAT, endellite Content and migration of radiocaesium and radiostrontium in Spanish soils, which is funded by the Plan I+D of the Spanish Nuclear Security Council (CSN). The objective of the project is to establish the reference levels of man-made radionuclides in Spanish soils, with respect to which the evaluation of a possible posterior accidental release of radioactive material could be appraised. The activity concentration of the fission products Cs-137 has been determined in 34 soil cores extracted from representative Spanish soils type zones. This publication describes the experimental system employed, its calibration, the particular conditions applied to perform the measurements, as well as the experimental validation of the methodology. The activity profiles and inventories of the radioactive element so obtained are also presented. The estimation of the background Cs-137 reference levels, will provide a basis for later applications as the study of the spatial distribution in the region, the determination of the correlation between the deposited activity and the meteorological conditions, or the calculation of the specific migration parameters of the radioactive elements in Mediterranean conditions. (Author) 15 refs

  5. Study of principle error sources in gamma spectrometry. Application to cross sections measurement

    International Nuclear Information System (INIS)

    Majah, M. Ibn.

    1985-01-01

    The principle error sources in gamma spectrometry have been studied in purpose to measure cross sections with great precision. Three error sources have been studied: dead time and pile up which depend on counting rate, and coincidence effect that depends on the disintegration scheme of the radionuclide in question. A constant frequency pulse generator has been used to correct the counting loss due to dead time and pile up in cases of long and short disintegration periods. The loss due to coincidence effect can reach 25% and over, depending on the disintegration scheme and on the distance source-detector. After establishing the correction formula and verifying its validity for four examples: iron 56, scandium 48, antimony 120 and gold 196 m, an application has been done by measuring cross sections of nuclear reactions that lead to long disintegration periods which need short distance source-detector counting and thus correcting the loss due to dead time effect, pile up and coincidence effect. 16 refs., 45 figs., 25 tabs. (author)

  6. In-situ-gamma-spectrometry intercomparison exercise in Salzburg, Austria, September 26-30, 1994

    International Nuclear Information System (INIS)

    Steger, F.; Lettner, H.; Andrasi, A.

    1996-06-01

    In-situ gamma spectrometry has become a useful method to assess the nuclide concentration of artificial and natural gamma-emitters in the soil. With such measurements it is possible to calculate the activity concentration in soil and also the nuclide specific exposure rates 1 m above ground. For the quality assurance of the measurements periodically intercomparison exercises are essential. To meet this requirement exercises were organised in different European countries since 1989. The last exercise in September 1994 was organised in Salzburg / Austria. The participation of 24 measurement teams from all over Europe emphasises the importance of the intercomparison. Salzburg was selected because the Province of Salzburg / Austria was among the heaviest contaminated region outside the former USSR by the Chernobyl fallout. Two different typical sites were selected for the measurements: Site 1 was inside the urban area of Salzburg on intensively used agricultural land which had not been disturbed since the fallout. This site is representative for intensively used agricultural regions in the Province of Salzburg. Site 2 was in the mountainous region of the Tauern on elevated altitude of approx. 1700 m. This site represents the soil and contamination conditions of the Alpine region. Both sites differ significantly in terms of different soil distribution and contents of natural and artificial radionuclides. Results of the intercomparison exercise are presented. (author)

  7. High resolution sequence stratigraphy in China

    International Nuclear Information System (INIS)

    Zhang Shangfeng; Zhang Changmin; Yin Yanshi; Yin Taiju

    2008-01-01

    Since high resolution sequence stratigraphy was introduced into China by DENG Hong-wen in 1995, it has been experienced two development stages in China which are the beginning stage of theory research and development of theory research and application, and the stage of theoretical maturity and widely application that is going into. It is proved by practices that high resolution sequence stratigraphy plays more and more important roles in the exploration and development of oil and gas in Chinese continental oil-bearing basin and the research field spreads to the exploration of coal mine, uranium mine and other strata deposits. However, the theory of high resolution sequence stratigraphy still has some shortages, it should be improved in many aspects. The authors point out that high resolution sequence stratigraphy should be characterized quantitatively and modelized by computer techniques. (authors)

  8. High resolution CT of the chest

    Energy Technology Data Exchange (ETDEWEB)

    Barneveld Binkhuysen, F H [Eemland Hospital (Netherlands), Dept. of Radiology

    1996-12-31

    Compared to conventional CT high resolution CT (HRCT) shows several extra anatomical structures which might effect both diagnosis and therapy. The extra anatomical structures were discussed briefly in this article. (18 refs.).

  9. High-resolution spectrometer at PEP

    International Nuclear Information System (INIS)

    Weiss, J.M.; HRS Collaboration.

    1982-01-01

    A description is presented of the High Resolution Spectrometer experiment (PEP-12) now running at PEP. The advanced capabilities of the detector are demonstrated with first physics results expected in the coming months

  10. Structure of high-resolution NMR spectra

    CERN Document Server

    Corio, PL

    2012-01-01

    Structure of High-Resolution NMR Spectra provides the principles, theories, and mathematical and physical concepts of high-resolution nuclear magnetic resonance spectra.The book presents the elementary theory of magnetic resonance; the quantum mechanical theory of angular momentum; the general theory of steady state spectra; and multiple quantum transitions, double resonance and spin echo experiments.Physicists, chemists, and researchers will find the book a valuable reference text.

  11. Airborne gamma spectrometry measurements in the context of the exercise ARM02

    International Nuclear Information System (INIS)

    Bucher, B.; Rybach, L.; Schwarz, G.; Baerlocher, C.

    2003-05-01

    The international exercise under the European Union project ECCOMAGS (European Coordination and Calibration of Mobile and Airborne Gamma Spectrometry) stood in the centre of the yearly airborne gamma spectrometry measurement flights which were carried out in the time of 27 -31 May 2002. The exercise was held in Southwest Scotland in the region of Dumfries and Galloway. Unfortunately due to difficulties with flight approvals for military aircrafts data could be taken in the exercise area only on the flight back to Switzerland. Immediately after returning to Switzerland the regular measurements around the nuclear power plants Beznau (KKB) and Leibstadt (KKL), around the intermediate storage facilities for radioactive waste (ZWILAG) and around the research facility Paul Scherrer Institute were performed. The flights took place in the context of the exercise ARM02 and were lead by the Swiss National Emergency Operations Centre (NAZ). Unfortunately just a few measurements in the common intercalibration areas could be taken on the flight back from the international exercise. Nevertheless comparisons of the results with those of other European teams could be made. These comparisons proved the good calibration of our equipment. On the flight back measurements were also carried out at great altitude above the sea. This data allowed to determine very well the background of the aircraft and the cosmic stripping ratios. In the context of the regular measurements in the environs of the nuclear facilities in Switzerland the areas around the nuclear power plants Beznau and Leibstadt and around the nuclear research facility Paul Scherrer Institute were measured. The results were very similar to the results of earlier measurements in the last years. The nuclear power plant Beznau couldn't be recognised on the activity maps. But the nuclear power plant Leibstadt could be identified by its direct radiation which is specific for this type of reactor (BWR). At the site of the Paul

  12. Efficiency transfer using the GEANT4 code of CERN for HPGe gamma spectrometry.

    Science.gov (United States)

    Chagren, S; Tekaya, M Ben; Reguigui, N; Gharbi, F

    2016-01-01

    In this work we apply the GEANT4 code of CERN to calculate the peak efficiency in High Pure Germanium (HPGe) gamma spectrometry using three different procedures. The first is a direct calculation. The second corresponds to the usual case of efficiency transfer between two different configurations at constant emission energy assuming a reference point detection configuration and the third, a new procedure, consists on the transfer of the peak efficiency between two detection configurations emitting the gamma ray in different energies assuming a "virtual" reference point detection configuration. No pre-optimization of the detector geometrical characteristics was performed before the transfer to test the ability of the efficiency transfer to reduce the effect of the ignorance on their real magnitude on the quality of the transferred efficiency. The obtained and measured efficiencies were found in good agreement for the two investigated methods of efficiency transfer. The obtained agreement proves that Monte Carlo method and especially the GEANT4 code constitute an efficient tool to obtain accurate detection efficiency values. The second investigated efficiency transfer procedure is useful to calibrate the HPGe gamma detector for any emission energy value for a voluminous source using one point source detection efficiency emitting in a different energy as a reference efficiency. The calculations preformed in this work were applied to the measurement exercise of the EUROMET428 project. A measurement exercise where an evaluation of the full energy peak efficiencies in the energy range 60-2000 keV for a typical coaxial p-type HpGe detector and several types of source configuration: point sources located at various distances from the detector and a cylindrical box containing three matrices was performed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. A simple gamma spectrometry method for evaluating the burnup of MTR-type HEU fuel elements

    Energy Technology Data Exchange (ETDEWEB)

    Makmal, T. [The Unit of Nuclear Engineering, Ben-Gurion University of The Negev, Beer-Sheva 84105 (Israel); Nuclear Physics and Engineering Division, Soreq Nuclear Research Center, Yavne 81800 (Israel); Aviv, O. [Radiation Safety Division, Soreq Nuclear Research Center, Yavne 81800 (Israel); Gilad, E., E-mail: gilade@bgu.ac.il [The Unit of Nuclear Engineering, Ben-Gurion University of The Negev, Beer-Sheva 84105 (Israel)

    2016-10-21

    A simple method for the evaluation of the burnup of a materials testing reactor (MTR) fuel element by gamma spectrometry is presented. The method was applied to a highly enriched uranium MTR nuclear fuel element that was irradiated in a 5 MW pool-type research reactor for a total period of 34 years. The experimental approach is based on in-situ measurements of the MTR fuel element in the reactor pool by a portable high-purity germanium detector located in a gamma cell. To corroborate the method, analytical calculations (based on the irradiation history of the fuel element) and computer simulations using a dedicated fuel cycle burnup code ORIGEN2 were performed. The burnup of the MTR fuel element was found to be 52.4±8.8%, which is in good agreement with the analytical calculations and the computer simulations. The method presented here is suitable for research reactors with either a regular or an irregular irradiation regime and for reactors with limited infrastructure and/or resources. In addition, its simplicity and the enhanced safety it confers may render this method suitable for IAEA inspectors in fuel element burnup assessments during on-site inspections. - Highlights: • Simple, inexpensive, safe and flexible experimental setup that can be quickly deployed. • Experimental results are thoroughly corroborated against ORIGEN2 burnup code. • Experimental uncertainty of 9% and 5% deviation between measurements and simulations. • Very high burnup MTR fuel element is examined, with 60% depletion of {sup 235}U. • Impact of highly irregular irradiation regime on burnup evaluation is studied.

  14. Natural and artificial nuclides in Salesópolis reservoir by gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Paulo S.C.; Semmler, Renato; Zahn, Guilherme S.; Rocha, Flávio R.; Damatto, Sandra R.; Fávaro, Déborah I.T., E-mail: pscsilva@ipen.br, E-mail: rsemmler@ipen.br, E-mail: gzahn@ipen.br, E-mail: flavio@baquara.com, E-mail: damatto@ipen.br, E-mail: defavaro@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    Natural radioactivity is ubiquitous in the environment mainly due to the presence of the nuclides from the uranium and thorium series and {sup 40}K. Although in the South Hemisphere nuclear tests have been fewer in number than that in the North, artificial radionuclides can also be found spread at ground level. In this study, the activity concentrations of natural nuclides from the uranium and thorium series, {sup 40}K and the artificial {sup 137}Cs were determined in a sediment core with 42 cm depth collected in the middle of the Salesópolis reservoir, located in the Metropolitan Region of São Paulo city (SPMR). The Usina Parque Rio Tietê reservoir belongs to the Alto do Tietê system for the capture, storage and treatment of water for SPMR. Therefore, the quality of the water and sediments of this dam is of great importance. The activity concentrations were measured by gamma spectrometry. Samples were measured and saved at regular intervals at a maximum of 160 000 seconds. The gross area were determined for each peak and plotted against time and the counting rate was obtained by the slope of the curve. Background and reference materials were also counted and treated in the same way. Results showed that {sup 226}Ra varied from 45 to 116 Bq kg{sup -1}; {sup 228}Ra, from 80 to 165 Bq kg{sup -1}; {sup 40}K, from 155 to 1 187 Bq kg{sup -1} and {sup 137}Cs varied from 0.3 to 7 Bq kg{sup -1}. The methodology applied for determining low levels of {sup 137}Cs in sediment proved to be efficient and reproducible. (author)

  15. Natural and artificial nuclides in Salesópolis reservoir by gamma spectrometry

    International Nuclear Information System (INIS)

    Silva, Paulo S.C.; Semmler, Renato; Zahn, Guilherme S.; Rocha, Flávio R.; Damatto, Sandra R.; Fávaro, Déborah I.T.

    2017-01-01

    Natural radioactivity is ubiquitous in the environment mainly due to the presence of the nuclides from the uranium and thorium series and 40 K. Although in the South Hemisphere nuclear tests have been fewer in number than that in the North, artificial radionuclides can also be found spread at ground level. In this study, the activity concentrations of natural nuclides from the uranium and thorium series, 40 K and the artificial 137 Cs were determined in a sediment core with 42 cm depth collected in the middle of the Salesópolis reservoir, located in the Metropolitan Region of São Paulo city (SPMR). The Usina Parque Rio Tietê reservoir belongs to the Alto do Tietê system for the capture, storage and treatment of water for SPMR. Therefore, the quality of the water and sediments of this dam is of great importance. The activity concentrations were measured by gamma spectrometry. Samples were measured and saved at regular intervals at a maximum of 160 000 seconds. The gross area were determined for each peak and plotted against time and the counting rate was obtained by the slope of the curve. Background and reference materials were also counted and treated in the same way. Results showed that 226 Ra varied from 45 to 116 Bq kg -1 ; 228 Ra, from 80 to 165 Bq kg -1 ; 40 K, from 155 to 1 187 Bq kg -1 and 137 Cs varied from 0.3 to 7 Bq kg -1 . The methodology applied for determining low levels of 137 Cs in sediment proved to be efficient and reproducible. (author)

  16. Study on the natural radioactivity from the region of Presidente Figueiredo (AM), Brazil, using gamma spectrometry

    International Nuclear Information System (INIS)

    Da Silva, Jose Ribamar Silveira

    1999-01-01

    A gamma spectrometry profile was carried out along BR174 highway, that crosses some lithostratigraphic units of the North portion of the Sedimentary Basin of Amazon. Measurements in situ were realized in 116 points, 1 km apart, using a GAD-6 gamma-spectrometer and samples of rocks and soils were collected in geologically representative points, for gamma measurements using a shielded detector of NaI(Tl) available in the Nuclear Geophysics Laboratory of IAG/USP. The criterion used for evaluating the reliability degree of the concentration values of eU (ppm), eTh (ppm) and %K was to establish mathematically detection limits, for all measurement points. Every these points had been located using GPS with accuracy of 50 m to become possible a future detailed study. The purpose of matching portable gamma spectrometer and laboratory determinations was to compare the 2 techniques, using the criterion of detectability limits, and to verify the influence of 222 Rn atmospheric radioactive gas in field measurements. In the case of portable detector, it allows fast measurements and the sensor 'sees' a big volume of material (rock, soil...), that makes it more representative. In some situations where atmospheric phenomena of thermal inversion occurs, measurement can be affected by the 222 Rn cosmic background. Presence of radon daughter elements, associated with aerosols, in this tropical environment (high values of temperature and humidity), where the speed of the wind that could exhaust this gas is practically zero. It is observed that the values of concentration in the some points, got with these 2 techniques, have the same trend, and the stretches where peaks of concentration of K also occur and U and Th are associated with the presence of granite out corps, great boulders, and clay soils from weathering of these rocks. (author)

  17. Gamma spectrometry and chemical characterization of bioactive glass seeds with Holmium-166 for oncological implants

    International Nuclear Information System (INIS)

    Valente, Eduardo S.

    2009-01-01

    Bioactive glass seeds synthesized by the sol-gel technique with Si:Ho:Ca composition with natural holmium incorporated were irradiated in the TRIGA type nuclear reactor IPR-R1 at 100kW, in the central thimble where the thermal neutron flux is 2.8x10 12 n/cm 2 .s and the epithermal neutron flux is 2.6 X 10 11 n/cm 2 .s . After an 8 hour irradiation time, with an induced activity close to 110MBq/seed, a set of seeds was submitted to Gamma Spectrometry Analysis in a counting system with an HPGe detector, ORTEC electronic instrumentation and a Camberra Multichannel Analyser, to determine all radionuclides present on the sample as well as its individual activities. Special attention was paid on the discrimination of Si, 40 Ca, 44 Ca, C and Ho as the other expected elements like 48 Ca, 2 H and 18 O were present in traces or have very short half-lives. The second sample was submitted to Plasma spectrometry to determine the 166 Ho concentration in weight. The third sample was submitted to an X-ray spectrometry in a JEOL-JXA-8900RL equipment to determine its qualitative chemical composition, in order to evaluate impurities and nominal composition. It was determined that most of the activity, after decaying of short half-life elements, was due to 166 Ho present on the sample, with a well characterized β and gamma spectra. The homogeneity of the seeds was tested on the X-ray spectrometry, and verified that there is no discrepancy in composition from distinct seeds or in a same seed. The results are relevant on the investigation of the viability of producing 166 Ho radioactive seeds for oncological implants. (author)

  18. A high resolution portable spectroscopy system

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Vaidya, P.P.; Paulson, M.; Bhatnagar, P.V.; Pande, S.S.; Padmini, S.

    2003-01-01

    Full text: This paper describes the system details of a High Resolution Portable Spectroscopy System (HRPSS) developed at Electronics Division, BARC. The system can be used for laboratory class, high-resolution nuclear spectroscopy applications. The HRPSS consists of a specially designed compact NIM bin, with built-in power supplies, accommodating a low power, high resolution MCA, and on-board embedded computer for spectrum building and communication. A NIM based spectroscopy amplifier and a HV module for detector bias are integrated (plug-in) in the bin. The system communicates with a host PC via a serial link. Along-with a laptop PC, and a portable HP-Ge detector, the HRPSS offers a laboratory class performance for portable applications

  19. High-resolution multi-slice PET

    International Nuclear Information System (INIS)

    Yasillo, N.J.; Chintu Chen; Ordonez, C.E.; Kapp, O.H.; Sosnowski, J.; Beck, R.N.

    1992-01-01

    This report evaluates the progress to test the feasibility and to initiate the design of a high resolution multi-slice PET system. The following specific areas were evaluated: detector development and testing; electronics configuration and design; mechanical design; and system simulation. The design and construction of a multiple-slice, high-resolution positron tomograph will provide substantial improvements in the accuracy and reproducibility of measurements of the distribution of activity concentrations in the brain. The range of functional brain research and our understanding of local brain function will be greatly extended when the development of this instrumentation is completed

  20. HPGe detectors long time behaviour in high-resolution γ spectrometry

    International Nuclear Information System (INIS)

    Sajo-Bohus, L.; Rosso, D.; Sajo Castelli, A.M.; Napoli, D.R.; Fioretto, E.; Menegazzo, R.; Barros, H.; Ur, C.A.; Palacios, D.; Liendo, J.

    2011-01-01

    A large set of data on long term performance of n-type HPGe detectors used in GASP, EUROBALL and CLARA γ spectrometers, as well as environmental measurements have been collected over two decades. In this paper a detailed statistical analysis of this data is given and detector long term behaviour is provided to the scientific community. We include failure, failure mode, repair frequency, repair outcome and its influence in the energy efficiency and energy resolution. A remarkable result is that the life span distribution is exponential. A detector's failure is a memory-less process, where a previous failure does not influence the upcoming one. Repaired spectrometers result in high reliability with deep implications in the management of large scale high-resolution gamma spectrometry related projects. Findings show that on average, detectors initial counting efficiency is slightly lower (∼2%) than that reported by the manufacturers and the repair process (including annealing) does not affect significantly the energy efficiency, even after a long period of use. Repaired detector energy resolution statistics show that the probability, that a repaired detector will be at least as good as it was originally, is more than 3/4.

  1. High resolution simultaneous measurements of airborne radionuclides in the pan-Japan sea area

    International Nuclear Information System (INIS)

    Yamaguchi, Y.; Abe, T.; Murata, Y.M.; Manikandan, N.; Tanaka, K.; Komura, K.

    2006-01-01

    By the use of ultra low background Ge detectors at Ogoya Underground Laboratory (OUL), it became possible to detect extremely low levels of environmental radionuclides. In this study, we tried to measure high resolution simultaneous measurements of airborne radionuclides at three monitoring points, i.e., 1) Low Level Radioactivity Laboratory (LLRL 40m asl) in Nomi City as the regular monitoring point, 2) Hegura Island Located 50 km from Noto Peninsula in the Sea of Japan to investigate the influence of Asian continent or mainland of Japan, and 3) Shishiku Plateau (640m asl) located about 8 km from LLRL to know vertical difference. Pb-210 and Be-7 were measured nondestructively by ultra low background gamma spectrometry at OUL, Po-210 by alpha spectrometry using Si detectors after the chemical treatment. Various interesting results on the concentrations and variation patterns of airborne radionuclides were obtained, particularly, during drastic meteorological changes such as the passage of typhoon, snow fall and so on. We have been analyzing the influence of the arrival of yellow sand occurred in this spring. (author)

  2. Neutron induced gamma spectrometry for on-line compositional analysis in coal conversion and fluidized-bed combustion plants

    International Nuclear Information System (INIS)

    Herzenberg, C.L.; O'Fallon, N.M.; Yarlagadda, B.S.; Doering, R.W.; Cohn, C.E.; Porges, K.G.; Duffey, D.

    1977-01-01

    Nuclear techniques involving relatively penetrating radiation may offer the possibility of non-invasive, continuous on-line instrumental monitoring which is representative of the full process stream. Prompt gamma rays following neutron capture are particularly attractive because the penetrating power of the neutrons and the, typically several MeV, capture gammas makes possible interrogation of material within a pipe. We are evaluating neutron capture gamma techniques for this application, both for elemental composition monitoring and for mass-flow measurement purposes, and this paper will present some recent work on composition analysis by neutron induced gamma spectrometry

  3. Uranium series radioactive disequilibria study using gamma spectrometry with low energy and application to the dating in geology

    International Nuclear Information System (INIS)

    Khoukhi, T. El.

    1992-01-01

    In this work, the gamma spectrometry with low energy has been used with the help of Ge high purity planar detector, and the means and limits of this spectrometry in the applications to the dating in geology has been studied. A geological sample taken from the moroccan phosphatic deposit of Gantour, having a secondary mineralization wealth of uranium has principally been studied in application. In addition, physical models of uranium genesis have been elaborated in the course of this work in order to interpret the achieved results. 60 figs., 18 tabs., 53 refs. (F.M.)

  4. Execution of a cooperative test by means of 'in-situ-gamma spectrometry' using HP-germanium detectors

    International Nuclear Information System (INIS)

    Steger, F.; Lovranich, E.; Urbanich, E.; Streit, S.

    1995-06-01

    A cooperative test was carried out in Salzburg, Austria, in order to determine the activity of Cs-137 and other radio nuclides from the Tschernobyl fallout 1986 and from tests of nuclear weapons in the 1960s. 24 groups from 9 countries of Europe took part. The measurements were performed by means of gamma spectrometry using HP-germanium detectors. Most of the groups had excellent results. The groups became acquainted with each other. The personal contact makes it possible to get information quickly in case of accidents of nuclear power stations in the neighbourhood of Austria

  5. Measuring the radium quartet ({sup 228}Ra, {sup 226}Ra, {sup 224}Ra, {sup 223}Ra) in seawater samples using gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Beek, P. van, E-mail: vanbeek@legos.obs-mip.f [LEGOS, Laboratoire d' Etudes en Geophysique et Oceanographie Spatiales (CNRS/CNES/IRD/UPS), Observatoire Midi Pyrenees, 14 Avenue Edouard Belin, 31400 Toulouse (France); Souhaut, M. [LEGOS, Laboratoire d' Etudes en Geophysique et Oceanographie Spatiales (CNRS/CNES/IRD/UPS), Observatoire Midi Pyrenees, 14 Avenue Edouard Belin, 31400 Toulouse (France); Reyss, J.-L. [LSCE, Laboratoire des Sciences du Climat et de l' Environnement (CNRS/CEA/UVSQ), Avenue de la Terrasse, 91198 Gif-sur-Yvette (France)

    2010-07-15

    Radium isotopes are widely used in marine studies (eg. to trace water masses, to quantify mixing processes or to study submarine groundwater discharge). While {sup 228}Ra and {sup 226}Ra are usually measured using gamma spectrometry, short-lived Ra isotopes ({sup 224}Ra and {sup 223}Ra) are usually measured using a Radium Delayed Coincidence Counter (RaDeCC). Here we show that the four radium isotopes can be analyzed using gamma spectrometry. We report {sup 226}Ra, {sup 228}Ra, {sup 224}Ra, {sup 223}Ra activities measured using low-background gamma spectrometry in standard samples, in water samples collected in the vicinity of our laboratory (La Palme and Vaccares lagoons, France) but also in seawater samples collected in the plume of the Amazon river, off French Guyana (AMANDES project). The {sup 223}Ra and {sup 224}Ra activities determined in these samples using gamma spectrometry were compared to the activities determined using RaDeCC. Activities determined using the two techniques are in good agreement. Uncertainties associated with the {sup 224}Ra activities are similar for the two techniques. RaDeCC is more sensitive for the detection of low {sup 223}Ra activities. Gamma spectrometry thus constitutes an alternate method for the determination of short-lived Ra isotopes.

  6. Determination of low-level Radium isotope activities in fresh waters by gamma spectrometry

    International Nuclear Information System (INIS)

    Molina Porras, Arnold; Condomines, Michel; Seidel, Jean Luc

    2017-01-01

    A new portable sampling system was developed to extract Radium isotopes from large volumes (up to 300 L) of fresh surface- and ground-waters of low Ra-activities (<5 mBq/L). Ra is quantitatively adsorbed on a small amount (6.5 g) of MnO_2-coated acrylic fibers, which are then dried and burned at 600 °C in the laboratory. The resulting Mn-oxide powder (about 2 cm"3 when compacted) is then analyzed through gamma-ray spectrometry which allows measurement of the whole Ra quartet ("2"2"6Ra, "2"2"8Ra, "2"2"4Ra and "2"2"3Ra) in a single counting of a few days. The usual relative standard combined uncertainties (1σ) are 2–3% for "2"2"6Ra, "2"2"8Ra and "2"2"4Ra; and less than 10% for "2"2"3Ra. This method was applied to the analysis of Ra in karstic waters of the Lez aquifer, and surface- and ground-waters of the upper and middle Vidourle watershed (South of France). The analyzed waters have relatively low "2"2"6Ra activities (1–4 mBq/L) in both cases, regardless of the contrasted geology (Mesozoic limestone vs crystalline Variscan basement), but clearly distinct ("2"2"8Ra/"2"2"6Ra) ratios in agreement with the differences in Th/U ratios of the two drained areas. Short-lived Ra isotopes ("2"2"4Ra and "2"2"3Ra) appear to be mainly influenced by near-surface desorption/recoil processes for most of the sampling sites. - Highlights: • New portable system for sampling fresh- and ground-waters of low Ra activities. • Simultaneous measurement of all four radium isotopes through gamma-spectrometry. • Relative uncertainties are 2% to 3% for "2"2"6Ra, "2"2"8Ra and "2"2"4Ra; and <10 % for "2"2"3Ra. • ("2"2"8Ra/"2"2"6Ra) ratios are valuable tracers of water origin in karstic aquifers.

  7. Statistical signal processing for gamma spectrometry: application for a pileup correction method

    International Nuclear Information System (INIS)

    Trigano, T.

    2005-12-01

    The main objective of gamma spectrometry is to characterize the radioactive elements of an unknown source by studying the energy of the emitted photons. When a photon interacts with a detector, its energy is converted into an electrical pulse. The histogram obtained by collecting the energies can be used to identify radioactive elements and measure their activity. However, at high counting rates, perturbations which are due to the stochastic aspect of the temporal signal can cripple the identification of the radioactive elements. More specifically, since the detector has a finite resolution, close arrival times of photons which can be modeled as an homogeneous Poisson process cause pile-ups of individual pulses. This phenomenon distorts energy spectra by introducing multiple fake spikes and prolonging artificially the Compton continuum, which can mask spikes of low intensity. The objective of this thesis is to correct the distortion caused by the pile-up phenomenon in the energy spectra. Since the shape of photonic pulses depends on many physical parameters, we consider this problem in a nonparametric framework. By introducing an adapted model based on two marked point processes, we establish a nonlinear relation between the probability measure associated to the observations and the probability density function we wish to estimate. This relation is derived both for continuous and for discrete time signals, and therefore can be used on a large set of detectors and from an analog or digital point of view. It also provides a framework to this problem, which can be considered as a problem of nonlinear density deconvolution and nonparametric density estimation from indirect measurements. Using these considerations, we propose an estimator obtained by direct inversion. We show that this estimator is consistent and almost achieves the usual rate of convergence obtained in classical nonparametric density estimation in the L 2 sense. We have applied our method to a set of

  8. High resolution Neutron and Synchrotron Powder Diffraction

    International Nuclear Information System (INIS)

    Hewat, A.W.

    1986-01-01

    The use of high-resolution powder diffraction has grown rapidly in the past years, with the development of Rietveld (1967) methods of data analysis and new high-resolution diffractometers and multidetectors. The number of publications in this area has increased from a handful per year until 1973 to 150 per year in 1984, with a ten-year total of over 1000. These papers cover a wide area of solid state-chemistry, physics and materials science, and have been grouped under 20 subject headings, ranging from catalysts to zeolites, and from battery electrode materials to pre-stressed superconducting wires. In 1985 two new high-resolution diffractometers are being commissioned, one at the SNS laboratory near Oxford, and one at the ILL in Grenoble. In different ways these machines represent perhaps the ultimate that can be achieved with neutrons and will permit refinement of complex structures with about 250 parameters and unit cell volumes of about 2500 Angstrom/sp3/. The new European Synchotron Facility will complement the Grenoble neutron diffractometers, and extend the role of high-resolution powder diffraction to the direct solution of crystal structures, pioneered in Sweden

  9. High resolution CT in diffuse lung disease

    International Nuclear Information System (INIS)

    Webb, W.R.

    1995-01-01

    High resolution CT (computerized tomography) was discussed in detail. The conclusions were HRCT is able to define lung anatomy at the secondary lobular level and define a variety of abnormalities in patients with diffuse lung diseases. Evidence from numerous studies indicates that HRCT can play a major role in the assessment of diffuse infiltrative lung disease and is indicate clinically (95 refs.)

  10. Classification of high resolution satellite images

    OpenAIRE

    Karlsson, Anders

    2003-01-01

    In this thesis the Support Vector Machine (SVM)is applied on classification of high resolution satellite images. Sveral different measures for classification, including texture mesasures, 1st order statistics, and simple contextual information were evaluated. Additionnally, the image was segmented, using an enhanced watershed method, in order to improve the classification accuracy.

  11. High resolution CT in diffuse lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Webb, W R [California Univ., San Francisco, CA (United States). Dept. of Radiology

    1996-12-31

    High resolution CT (computerized tomography) was discussed in detail. The conclusions were HRCT is able to define lung anatomy at the secondary lobular level and define a variety of abnormalities in patients with diffuse lung diseases. Evidence from numerous studies indicates that HRCT can play a major role in the assessment of diffuse infiltrative lung disease and is indicate clinically (95 refs.).

  12. High-resolution clean-sc

    NARCIS (Netherlands)

    Sijtsma, P.; Snellen, M.

    2016-01-01

    In this paper a high-resolution extension of CLEAN-SC is proposed: HR-CLEAN-SC. Where CLEAN-SC uses peak sources in “dirty maps” to define so-called source components, HR-CLEAN-SC takes advantage of the fact that source components can likewise be derived from points at some distance from the peak,

  13. A High-Resolution Stopwatch for Cents

    Science.gov (United States)

    Gingl, Z.; Kopasz, K.

    2011-01-01

    A very low-cost, easy-to-make stopwatch is presented to support various experiments in mechanics. The high-resolution stopwatch is based on two photodetectors connected directly to the microphone input of a sound card. Dedicated free open-source software has been developed and made available to download. The efficiency is demonstrated by a free…

  14. Planning for shallow high resolution seismic surveys

    CSIR Research Space (South Africa)

    Fourie, CJS

    2008-11-01

    Full Text Available of the input wave. This information can be used in conjunction with this spreadsheet to aid the geophysicist in designing shallow high resolution seismic surveys to achieve maximum resolution and penetration. This Excel spreadsheet is available free from...

  15. High-Resolution Fast-Neutron Spectrometry for Arms Control and Treaty Verification

    Energy Technology Data Exchange (ETDEWEB)

    David L. Chichester; James T. Johnson; Edward H. Seabury

    2012-07-01

    Many nondestructive nuclear analysis techniques have been developed to support the measurement needs of arms control and treaty verification, including gross photon and neutron counting, low- and high-resolution gamma spectrometry, time-correlated neutron measurements, and photon and neutron imaging. One notable measurement technique that has not been extensively studied to date for these applications is high-resolution fast-neutron spectrometry (HRFNS). Applied for arms control and treaty verification, HRFNS has the potential to serve as a complimentary measurement approach to these other techniques by providing a means to either qualitatively or quantitatively determine the composition and thickness of non-nuclear materials surrounding neutron-emitting materials. The technique uses the normally-occurring neutrons present in arms control and treaty verification objects of interest as an internal source of neutrons for performing active-interrogation transmission measurements. Most low-Z nuclei of interest for arms control and treaty verification, including 9Be, 12C, 14N, and 16O, possess fast-neutron resonance features in their absorption cross sections in the 0.5- to 5-MeV energy range. Measuring the selective removal of source neutrons over this energy range, assuming for example a fission-spectrum starting distribution, may be used to estimate the stoichiometric composition of intervening materials between the neutron source and detector. At a simpler level, determination of the emitted fast-neutron spectrum may be used for fingerprinting 'known' assemblies for later use in template-matching tests. As with photon spectrometry, automated analysis of fast-neutron spectra may be performed to support decision making and reporting systems protected behind information barriers. This paper will report recent work at Idaho National Laboratory to explore the feasibility of using HRFNS for arms control and treaty verification applications, including simulations

  16. Integrated evaluation of the geology, aero gamma spectrometry and aero magnetometry of the Sul-Riograndense Shield, southernmost Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, Leo A.; Savian, Jairo F., E-mail: leo.hartmann@ufrgs.br [Universidade Federal do Rio Grande do Sul (UFRS), Porto Alegre, RS (Brazil). Instituto de Geociencias; Lopes, William R. [Servico Geologico do Brasil (CPRM), Porto Alegre, RS (Brazil). Gerencia de Geologia e Mineracao

    2016-03-15

    An integrated evaluation of geology, aero gamma spectrometry and aero magnetometry of the Sul-Riograndense Shield is permitted by the advanced stage of understanding of the geology and geochronology of the southern Brazilian Shield and a 2010 airborne geophysical survey. Gamma rays are registered from the rocks near the surface and thus describe the distribution of major units in the shield, such as the Pelotas batholith, the juvenile São Gabriel terrane, the granulite-amphibolite facies Taquarembo terrane and the numerous granite intrusions in the foreland. Major structures are also observed, e.g., the Dorsal de Cangucu shear. Magnetic signals register near surface crustal compositions (analytic signal) and total crust composition (total magnetic signal), so their variation as measured indicates either shallow or whole crustal structures. The Cacapava shear is outstanding on the images as is the magnetic low along the N-S central portion of the shield. These integrated observations lead to the deepening of the understanding of the largest and even detailed structures of the Sul-Riograndense Shield, some to be correlated to field geology in future studies. Most significant is the presence of different provinces and their limits depending on the method used for data acquisition - geology, aero gamma spectrometry or aero magnetometry. (author)

  17. Smartphone microendoscopy for high resolution fluorescence imaging

    Directory of Open Access Journals (Sweden)

    Xiangqian Hong

    2016-09-01

    Full Text Available High resolution optical endoscopes are increasingly used in diagnosis of various medical conditions of internal organs, such as the cervix and gastrointestinal (GI tracts, but they are too expensive for use in resource-poor settings. On the other hand, smartphones with high resolution cameras and Internet access have become more affordable, enabling them to diffuse into most rural areas and developing countries in the past decade. In this paper, we describe a smartphone microendoscope that can take fluorescence images with a spatial resolution of 3.1 μm. Images collected from ex vivo, in vitro and in vivo samples using the device are also presented. The compact and cost-effective smartphone microendoscope may be envisaged as a powerful tool for detecting pre-cancerous lesions of internal organs in low and middle-income countries (LMICs.

  18. High resolution NMR theory and chemical applications

    CERN Document Server

    Becker, Edwin D

    2012-01-01

    High Resolution NMR: Theory and Chemical Applications discusses the principles and theory of nuclear magnetic resonance and how this concept is used in the chemical sciences. This book is written at an intermediate level, with mathematics used to augment verbal descriptions of the phenomena. This text pays attention to developing and interrelating four approaches - the steady state energy levels, the rotating vector picture, the density matrix, and the product operator formalism. The style of this book is based on the assumption that the reader has an acquaintance with the general principles of quantum mechanics, but no extensive background in quantum theory or proficiency in mathematics is required. This book begins with a description of the basic physics, together with a brief account of the historical development of the field. It looks at the study of NMR in liquids, including high resolution NMR in the solid state and the principles of NMR imaging and localized spectroscopy. This book is intended to assis...

  19. High resolution NMR theory and chemical applications

    CERN Document Server

    Becker, Edwin D

    1999-01-01

    High Resolution NMR provides a broad treatment of the principles and theory of nuclear magnetic resonance (NMR) as it is used in the chemical sciences. It is written at an "intermediate" level, with mathematics used to augment, rather than replace, clear verbal descriptions of the phenomena. The book is intended to allow a graduate student, advanced undergraduate, or researcher to understand NMR at a fundamental level, and to see illustrations of the applications of NMR to the determination of the structure of small organic molecules and macromolecules, including proteins. Emphasis is on the study of NMR in liquids, but the treatment also includes high resolution NMR in the solid state and the principles of NMR imaging and localized spectroscopy. Careful attention is given to developing and interrelating four approaches - steady state energy levels, the rotating vector picture, the density matrix, and the product operator formalism. The presentation is based on the assumption that the reader has an acquaintan...

  20. High resolution imaging of boron carbide microstructures

    International Nuclear Information System (INIS)

    MacKinnon, I.D.R.; Aselage, T.; Van Deusen, S.B.

    1986-01-01

    Two samples of boron carbide have been examined using high resolution transmission electron microscopy (HRTEM). A hot-pressed B 13 C 2 sample shows a high density of variable width twins normal to (10*1). Subtle shifts or offsets of lattice fringes along the twin plane and normal to approx.(10*5) were also observed. A B 4 C powder showed little evidence of stacking disorder in crystalline regions

  1. High-Resolution MRI in Rectal Cancer

    International Nuclear Information System (INIS)

    Dieguez, Adriana

    2010-01-01

    High-resolution MRI is the best method of assessing the relation of the rectal tumor with the potential circumferential resection margin (CRM). Therefore it is currently considered the method of choice for local staging of rectal cancer. The primary surgery of rectal cancer is total mesorectal excision (TME), which plane of dissection is formed by the mesorectal fascia surrounding mesorectal fat and rectum. This fascia will determine the circumferential margin of resection. At the same time, high resolution MRI allows adequate pre-operative identification of important prognostic risk factors, improving the selection and indication of therapy for each patient. This information includes, besides the circumferential margin of resection, tumor and lymph node staging, extramural vascular invasion and the description of lower rectal tumors. All these should be described in detail in the report, being part of the discussion in the multidisciplinary team, the place where the decisions involving the patient with rectal cancer will take place. The aim of this study is to provide the information necessary to understand the use of high resolution MRI in the identification of prognostic risk factors in rectal cancer. The technical requirements and standardized report for this study will be describe, as well as the anatomical landmarks of importance for the total mesorectal excision (TME), as we have said is the surgery of choice for rectal cancer. (authors) [es

  2. Ultra-high resolution protein crystallography

    International Nuclear Information System (INIS)

    Takeda, Kazuki; Hirano, Yu; Miki, Kunio

    2010-01-01

    Many protein structures have been determined by X-ray crystallography and deposited with the Protein Data Bank. However, these structures at usual resolution (1.5< d<3.0 A) are insufficient in their precision and quantity for elucidating the molecular mechanism of protein functions directly from structural information. Several studies at ultra-high resolution (d<0.8 A) have been performed with synchrotron radiation in the last decade. The highest resolution of the protein crystals was achieved at 0.54 A resolution for a small protein, crambin. In such high resolution crystals, almost all of hydrogen atoms of proteins and some hydrogen atoms of bound water molecules are experimentally observed. In addition, outer-shell electrons of proteins can be analyzed by the multipole refinement procedure. However, the influence of X-rays should be precisely estimated in order to derive meaningful information from the crystallographic results. In this review, we summarize refinement procedures, current status and perspectives for ultra high resolution protein crystallography. (author)

  3. Methodology for determination of activity of radionuclides by gamma spectrometry; Metodologia para determinacao da atividade de radionuclideos por sistema de espectrometria gama

    Energy Technology Data Exchange (ETDEWEB)

    Fragoso, Maria da Conceicao de Farias; Oliveira, Victor Rogerio S. de; Oliveira, Mercia L.; Lima, Fernando Roberto de Andrade, E-mail: mariacc05@gmail.com [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-NE), Recife, PE (Brazil)

    2014-07-01

    Due to the growth in the number of procedures that make use of the positron emission tomography (PET), there is a need for standard solutions for the calibration of the systems used for the measurement of the PET radiopharmaceutical (activimeter) in radiopharmacies and in nuclear medicine services. Among the existing alternatives for the standardization of radioactive sources, the method known as gamma spectrometry is widely used for short-lived radionuclides. The purpose of this study was to implement the methodology for standardization of the {sup 18}F solutions by gamma spectrometry at the Regional Center for Nuclear Sciences of the Northeast (CRCN-NE/CNEN-NE), Brazil. (author)

  4. The metrological activity determination of {sup 238} U and {sup 230} Th by gamma spectrometry to industrial fuel-cycle application

    Energy Technology Data Exchange (ETDEWEB)

    Almeida M, M.C. de; Delgado, J.U.; Poledna, R. [Instituto de Radioprotecao e Dosimetria- IRD/SEMRA, CNEN, Av. Salvador Allende s/n, Recreio, CEP 22780-160, Rio de Janeiro (Brazil)]. e-mail: marcandida@yahoo.com.br

    2006-07-01

    This work describes the difficulty for determining the activity of {sup 238} U and {sup 230} Th using gamma spectrometry due to the low gamma-ray emission probabilities of 92 and 67 keV, and, mainly, the associated high uncertainties about 13 and 11%, respectively. {sup 230} Th is a {sup 238} U daughter and it is product from uranium mills and refineries. {sup 230} Th decays to {sup 226} Ra and this decay has to be measured because these radionuclides are not in secular equilibrium with their daughter products, besides the gamma-energies have high uncertainties in the emission probabilities. These radionuclides, mostly {sup 238} U, are important in the nuclear fuel-cycle, since the mining of uranium ore, where the nominal isotopic content of natural uranium is 99.27% of {sup 238} U, until the irradiated fuel reprocessing, where this isotope, a fertile material, is recovered to be used again. The uranium and thorium are considered safeguarded nuclear materials and the metrology tries to calibrate and standardize these materials to improve the activity determination techniques applied in different fuel-cycle scopes. The essential characteristics of the safeguarded materials are low gamma energies (less than 100 keV) and emission probabilities but with high uncertainties. In this way, the metrology can contribute to homeland security defense against illicit nuclear trafficking with the identification and quantification of the safeguarded radionuclides such as uranium and thorium, using specific gamma window energy and high resolution planar or coaxial germanium detector. The efficiency curve is obtained from the reference source spectrum considering the photopeak areas corresponding the standard activities. This curve depends on radiation energy, sample geometry, photon attenuation (sample absorption and material absorption between sample-detector), dead time and sample-detector position. The metrological activity determinations of {sup 238} U solid sources, and of

  5. Remote and continuous gamma spectrometry for environmental radiation protection: A review of potential applications

    International Nuclear Information System (INIS)

    Put, Ph. V.; Debauche, A.; Lacroix, J-P.; Lellis, C. D.; Delecaut, G.

    2006-01-01

    The first nuclear metrology tools for surface water surveillance have been designed in the early 80's. The detection systems were based on the use of a NaI(Tl) detector connected to two Single Channel Analyzers (SCA). The detector was placed in a shielded vessel fed with the water to be analysed through a pump. The analysis was rudimentary. The systems were suffering the inherent temperature drift from the detector. For this reasons the system required frequent maintenance for the mechanical parts and the detection system calibration. The sensitivity of the system was about 10-100 Bq/l, which make it useful for monitoring accidental releases from base nuclear installations. Technical evolutions in the fields of computer sciences and telecommunication have allowed the IRE to develop an original instrument able to detect and to quantify very small radioactivity increase in surface water. The system is based on a NaI(Tl) detector connected to a multi-channel analyzer. The detection system is now directly placed in the medium to survey. The analysis is performed using gamma spectrometry technique. In this way the detector temperature drift is compensated thanks to a special algorithm, the spectral analysis permits to discriminate natural and artificial radioactivity and the detection system is much more sensitive. The design of the detection system without pump make feasible to feed it with solar energy and consequently to install it in any aquatic environment (sea, lake ...). The need for regular maintenance is reduced considerably. This system has been successfully implemented in sea and river waters. The system stability is unique for NaI(Tl) based detection system. The detection limit has been considerably lowered - for 1 37Cs in seawater - containing 12 Bq/l of 4 0K - it is in the range 0.13-0.22 Bq/l for a 2-hours measurement, while it is in the range 0.65-0.85 Bq/l for a 2-hours counting time in river water. The reported detection limit in river water is higher

  6. High resolution, high speed ultrahigh vacuum microscopy

    International Nuclear Information System (INIS)

    Poppa, Helmut

    2004-01-01

    The history and future of transmission electron microscopy (TEM) is discussed as it refers to the eventual development of instruments and techniques applicable to the real time in situ investigation of surface processes with high resolution. To reach this objective, it was necessary to transform conventional high resolution instruments so that an ultrahigh vacuum (UHV) environment at the sample site was created, that access to the sample by various in situ sample modification procedures was provided, and that in situ sample exchanges with other integrated surface analytical systems became possible. Furthermore, high resolution image acquisition systems had to be developed to take advantage of the high speed imaging capabilities of projection imaging microscopes. These changes to conventional electron microscopy and its uses were slowly realized in a few international laboratories over a period of almost 40 years by a relatively small number of researchers crucially interested in advancing the state of the art of electron microscopy and its applications to diverse areas of interest; often concentrating on the nucleation, growth, and properties of thin films on well defined material surfaces. A part of this review is dedicated to the recognition of the major contributions to surface and thin film science by these pioneers. Finally, some of the important current developments in aberration corrected electron optics and eventual adaptations to in situ UHV microscopy are discussed. As a result of all the path breaking developments that have led to today's highly sophisticated UHV-TEM systems, integrated fundamental studies are now possible that combine many traditional surface science approaches. Combined investigations to date have involved in situ and ex situ surface microscopies such as scanning tunneling microscopy/atomic force microscopy, scanning Auger microscopy, and photoemission electron microscopy, and area-integrating techniques such as x-ray photoelectron

  7. USGS High Resolution Orthoimagery Collection - Historical - National Geospatial Data Asset (NGDA) High Resolution Orthoimagery

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — USGS high resolution orthorectified images from The National Map combine the image characteristics of an aerial photograph with the geometric qualities of a map. An...

  8. Determination of activity by gamma spectrometry of radionuclides present in drums of residues generated in nuclear centrals

    International Nuclear Information System (INIS)

    Aguiar, J.C.; Fernandez, J.

    2006-01-01

    The generation of radioactive residuals in nuclear centrals as CNA I (Atucha I Nuclear Central) and CNE (Embalse Nuclear Central) makes that the measurement of those radionuclides has been a previous stage to the waste management. A method used in those nuclear centrals it is the gamma spectrometry with HPGe detectors, previous to the immobilization of the residual in a cemented matrix, with this the contact with the external agents and its possible dispersion to the atmosphere in the short term is avoided. The ARN (Nuclear Regulatory Authority) of Argentina it carries out periodically intercomparisons and evaluations of the measurement and procedures systems used in the nuclear power stations for the correct measurement and determination of activity of radioactive residuals by gamma spectrometry. In this work an independent method of measurement is exposed to the nuclear power stations. To determine the activity of the residuals by gamma spectrometry deposited in drums, it is required of the precise knowledge of the efficiency curve for such geometry and matrix. Due to the RNA doesn't have a pattern of these characteristics, a mathematical model has been used to obtain this efficiency curve. For it, it is necessary to determine previously: 1) the geometric efficiency or solid angle sustained by the source-detector system (drum-detector) applying a mathematical model described in this work. 2) To estimate the auto-attenuation factor that present the photons in the cemented matrix, these calculations are carried out with a simple equation and its are verified with the Micro Shield 6.10 program. The container commonly used by these nuclear power stations its are drums for 220 liters constructed with SAE 1010 steel and with a thickness of 0.127 cm, with an approximate weight 7.73 Kg., internal diameter of 57.1 cm, and height: 87 cm. The results obtained until the moment register a discrepancy from 5 to 10% with relationship to the measurements carried out by the

  9. High resolution extremity CT for biomechanics modeling

    International Nuclear Information System (INIS)

    Ashby, A.E.; Brand, H.; Hollerbach, K.; Logan, C.M.; Martz, H.E.

    1995-01-01

    With the advent of ever more powerful computing and finite element analysis (FEA) capabilities, the bone and joint geometry detail available from either commercial surface definitions or from medical CT scans is inadequate. For dynamic FEA modeling of joints, precise articular contours are necessary to get appropriate contact definition. In this project, a fresh cadaver extremity was suspended in parafin in a lucite cylinder and then scanned with an industrial CT system to generate a high resolution data set for use in biomechanics modeling

  10. Ultra-high resolution coded wavefront sensor

    KAUST Repository

    Wang, Congli

    2017-06-08

    Wavefront sensors and more general phase retrieval methods have recently attracted a lot of attention in a host of application domains, ranging from astronomy to scientific imaging and microscopy. In this paper, we introduce a new class of sensor, the Coded Wavefront Sensor, which provides high spatio-temporal resolution using a simple masked sensor under white light illumination. Specifically, we demonstrate megapixel spatial resolution and phase accuracy better than 0.1 wavelengths at reconstruction rates of 50 Hz or more, thus opening up many new applications from high-resolution adaptive optics to real-time phase retrieval in microscopy.

  11. High resolution extremity CT for biomechanics modeling

    Energy Technology Data Exchange (ETDEWEB)

    Ashby, A.E.; Brand, H.; Hollerbach, K.; Logan, C.M.; Martz, H.E.

    1995-09-23

    With the advent of ever more powerful computing and finite element analysis (FEA) capabilities, the bone and joint geometry detail available from either commercial surface definitions or from medical CT scans is inadequate. For dynamic FEA modeling of joints, precise articular contours are necessary to get appropriate contact definition. In this project, a fresh cadaver extremity was suspended in parafin in a lucite cylinder and then scanned with an industrial CT system to generate a high resolution data set for use in biomechanics modeling.

  12. High-resolution computer-aided moire

    Science.gov (United States)

    Sciammarella, Cesar A.; Bhat, Gopalakrishna K.

    1991-12-01

    This paper presents a high resolution computer assisted moire technique for the measurement of displacements and strains at the microscopic level. The detection of micro-displacements using a moire grid and the problem associated with the recovery of displacement field from the sampled values of the grid intensity are discussed. A two dimensional Fourier transform method for the extraction of displacements from the image of the moire grid is outlined. An example of application of the technique to the measurement of strains and stresses in the vicinity of the crack tip in a compact tension specimen is given.

  13. SPIRAL2/DESIR high resolution mass separator

    Energy Technology Data Exchange (ETDEWEB)

    Kurtukian-Nieto, T., E-mail: kurtukia@cenbg.in2p3.fr [Centre d’Études Nucléaires de Bordeaux Gradignan, Université Bordeaux 1-CNRS/IN2P3, BP 120, F-33175 Gradignan Cedex (France); Baartman, R. [TRIUMF, 4004 Wesbrook Mall, Vancouver B.C., V6T 2A3 (Canada); Blank, B.; Chiron, T. [Centre d’Études Nucléaires de Bordeaux Gradignan, Université Bordeaux 1-CNRS/IN2P3, BP 120, F-33175 Gradignan Cedex (France); Davids, C. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Delalee, F. [Centre d’Études Nucléaires de Bordeaux Gradignan, Université Bordeaux 1-CNRS/IN2P3, BP 120, F-33175 Gradignan Cedex (France); Duval, M. [GANIL, CEA/DSM-CNRS/IN2P3, Bd Henri Becquerel, BP 55027, F-14076 Caen Cedex 5 (France); El Abbeir, S.; Fournier, A. [Centre d’Études Nucléaires de Bordeaux Gradignan, Université Bordeaux 1-CNRS/IN2P3, BP 120, F-33175 Gradignan Cedex (France); Lunney, D. [CSNSM-IN2P3-CNRS, Université de Paris Sud, F-91405 Orsay (France); Méot, F. [BNL, Upton, Long Island, New York (United States); Serani, L. [Centre d’Études Nucléaires de Bordeaux Gradignan, Université Bordeaux 1-CNRS/IN2P3, BP 120, F-33175 Gradignan Cedex (France); Stodel, M.-H.; Varenne, F. [GANIL, CEA/DSM-CNRS/IN2P3, Bd Henri Becquerel, BP 55027, F-14076 Caen Cedex 5 (France); and others

    2013-12-15

    DESIR is the low-energy part of the SPIRAL2 ISOL facility under construction at GANIL. DESIR includes a high-resolution mass separator (HRS) with a designed resolving power m/Δm of 31,000 for a 1 π-mm-mrad beam emittance, obtained using a high-intensity beam cooling device. The proposed design consists of two 90-degree magnetic dipoles, complemented by electrostatic quadrupoles, sextupoles, and a multipole, arranged in a symmetric configuration to minimize aberrations. A detailed description of the design and results of extensive simulations are given.

  14. High resolution neutron spectroscopy for helium isotopes

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; Klages, H.O.; Schmalz, G.; Haesner, B.H.; Kecskemeti, J.; Schwarz, P.; Wilczynski, J.

    1992-01-01

    A high resolution fast neutron time-of-flight spectrometer is described, neutron time-of-flight spectra are taken using a specially designed TDC in connection to an on-line computer. The high time-of-flight resolution of 5 ps/m enabled the study of the total cross section of 4 He for neutrons near the 3/2 + resonance in the 5 He nucleus. The resonance parameters were determined by a single level Breit-Winger fit to the data. (orig.)

  15. Limiting liability via high resolution image processing

    Energy Technology Data Exchange (ETDEWEB)

    Greenwade, L.E.; Overlin, T.K.

    1996-12-31

    The utilization of high resolution image processing allows forensic analysts and visualization scientists to assist detectives by enhancing field photographs, and by providing the tools and training to increase the quality and usability of field photos. Through the use of digitized photographs and computerized enhancement software, field evidence can be obtained and processed as `evidence ready`, even in poor lighting and shadowed conditions or darkened rooms. These images, which are most often unusable when taken with standard camera equipment, can be shot in the worst of photographic condition and be processed as usable evidence. Visualization scientists have taken the use of digital photographic image processing and moved the process of crime scene photos into the technology age. The use of high resolution technology will assist law enforcement in making better use of crime scene photography and positive identification of prints. Valuable court room and investigation time can be saved and better served by this accurate, performance based process. Inconclusive evidence does not lead to convictions. Enhancement of the photographic capability helps solve one major problem with crime scene photos, that if taken with standard equipment and without the benefit of enhancement software would be inconclusive, thus allowing guilty parties to be set free due to lack of evidence.

  16. High-Resolution Scintimammography: A Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Rachel F. Brem; Joelle M. Schoonjans; Douglas A. Kieper; Stan Majewski; Steven Goodman; Cahid Civelek

    2002-07-01

    This study evaluated a novel high-resolution breast-specific gamma camera (HRBGC) for the detection of suggestive breast lesions. Methods: Fifty patients (with 58 breast lesions) for whom a scintimammogram was clinically indicated were prospectively evaluated with a general-purpose gamma camera and a novel HRBGC prototype. The results of conventional and high-resolution nuclear studies were prospectively classified as negative (normal or benign) or positive (suggestive or malignant) by 2 radiologists who were unaware of the mammographic and histologic results. All of the included lesions were confirmed by pathology. Results: There were 30 benign and 28 malignant lesions. The sensitivity for detection of breast cancer was 64.3% (18/28) with the conventional camera and 78.6% (22/28) with the HRBGC. The specificity with both systems was 93.3% (28/30). For the 18 nonpalpable lesions, sensitivity was 55.5% (10/18) and 72.2% (13/18) with the general-purpose camera and the HRBGC, respectively. For lesions 1 cm, 7 of 15 were detected with the general-purpose camera and 10 of 15 with the HRBGC. Four lesions (median size, 8.5 mm) were detected only with the HRBGC and were missed by the conventional camera. Conclusion: Evaluation of indeterminate breast lesions with an HRBGC results in improved sensitivity for the detection of cancer, with greater improvement shown for nonpalpable and 1-cm lesions.

  17. High resolution studies of barium Rydberg states

    International Nuclear Information System (INIS)

    Eliel, E.R.

    1982-01-01

    The subtle structure of Rydberg states of barium with orbital angular momentum 0, 1, 2 and 3 is investigated. Some aspects of atomic theory for a configuration with two valence electrons are reviewed. The Multi Channel Quantum Defect Theory (MQDT) is concisely introduced as a convenient way to describe interactions between Rydberg series. Three high-resolution UV studies are presented. The first two, presenting results on a transition in indium and europium serve as an illustration of the frequency doubling technique. The third study is of hyperfine structure and isotope shifts in low-lying p states in Sr and Ba. An extensive study of the 6snp and 6snf Rydberg states of barium is presented with particular emphasis on the 6snf states. It is shown that the level structure cannot be fully explained with the model introduced earlier. Rather an effective two-body spin-orbit interaction has to be introduced to account for the observed splittings, illustrating that high resolution studies on Rydberg states offer an unique opportunity to determine the importance of such effects. Finally, the 6sns and 6snd series are considered. The hyperfine induced isotope shift in the simple excitation spectra to 6sns 1 S 0 is discussed and attention is paid to series perturbers. It is shown that level mixing parameters can easily be extracted from the experimental data. (Auth.)

  18. Principles of high resolution NMR in solids

    CERN Document Server

    Mehring, Michael

    1983-01-01

    The field of Nuclear Magnetic Resonance (NMR) has developed at a fascinating pace during the last decade. It always has been an extremely valuable tool to the organic chemist by supplying molecular "finger print" spectra at the atomic level. Unfortunately the high resolution achievable in liquid solutions could not be obtained in solids and physicists and physical chemists had to live with unresolved lines open to a wealth of curve fitting procedures and a vast amount of speculations. High resolution NMR in solids seemed to be a paradoxon. Broad structure­ less lines are usually encountered when dealing with NMR in solids. Only with the recent advent of mUltiple pulse, magic angle, cross-polarization, two-dimen­ sional and multiple-quantum spectroscopy and other techniques during the last decade it became possible to resolve finer details of nuclear spin interactions in solids. I have felt that graduate students, researchers and others beginning to get involved with these techniques needed a book which trea...

  19. High-Resolution PET Detector. Final report

    International Nuclear Information System (INIS)

    Karp, Joel

    2014-01-01

    The objective of this project was to develop an understanding of the limits of performance for a high resolution PET detector using an approach based on continuous scintillation crystals rather than pixelated crystals. The overall goal was to design a high-resolution detector, which requires both high spatial resolution and high sensitivity for 511 keV gammas. Continuous scintillation detectors (Anger cameras) have been used extensively for both single-photon and PET scanners, however, these instruments were based on NaI(Tl) scintillators using relatively large, individual photo-multipliers. In this project we investigated the potential of this type of detector technology to achieve higher spatial resolution through the use of improved scintillator materials and photo-sensors, and modification of the detector surface to optimize the light response function.We achieved an average spatial resolution of 3-mm for a 25-mm thick, LYSO continuous detector using a maximum likelihood position algorithm and shallow slots cut into the entrance surface

  20. Use of wavelet based iterative filtering to improve denoising of spectral information for in-vivo gamma spectrometry

    International Nuclear Information System (INIS)

    Paul, Sabyasachi; Sarkar, P.K.

    2012-05-01

    The characterization of radionuclide in the in-vivo monitoring analysis using gamma spectrometry poses difficulty due to very low activity level in biological systems. The large statistical fluctuations often make identification of characteristic gammas from radionuclides highly uncertain, particularly when interferences from progenies are also present. A new wavelet based noise filtering methodology has been developed for better detection of gamma peaks while analyzing noisy spectrometric data. This sequential, iterative filtering method uses the wavelet multi-resolution approach for the noise rejection and inverse transform after soft thresholding over the generated coefficients. Analyses of in-vivo monitoring data of 235 U and 238 U have been carried out using this method without disturbing the peak position and amplitude while achieving a threefold improvement in the signal to noise ratio, compared to the original measured spectrum. When compared with other data filtering techniques, the wavelet based method shows better results. (author)

  1. Medium-term experiences with in-situ gamma-spectrometry of the primary loop transport processes at Paks NPP

    International Nuclear Information System (INIS)

    Raics, P.; Sztaricskai, T.; Szabo, J.; Szegedi, S.

    2001-01-01

    Surface activity of 15 corrosion/erosion and fission products was determined by in-situ gamma-spectrometry for 2-2 locations on the hot and cold legs of each loop, respectively. Gamma-dosimetry in the assay points was performed. Activity profiles of ion exchange columns were analyzed. Combined measurements along the steam generators completed the characterization of the primary circuits. Most of this technique was regularly included into all maintenance periods. Data evaluation was performed for the surface contaminations as well as coolant activities and reactor operation features for years 1985-2001. Trends and tendencies were investigated in the time behavior of the specific activities. Asymmetry in the surface contamination at the primary loop points, cold-leg activity inversion, water chemistry effects, isotope selectivity were observed. Correlations in different parameters have been calculated and analyzed. (R.P.)

  2. Validation by theoretical approach to the experimental estimation of efficiency for gamma spectrometry of gas in 100 ml standard flask

    International Nuclear Information System (INIS)

    Mohan, V.; Chudalayandi, K.; Sundaram, M.; Krishnamony, S.

    1996-01-01

    Estimation of gaseous activity forms an important component of air monitoring at Madras Atomic Power Station (MAPS). The gases of importance are argon 41 an air activation product and fission product noble gas xenon 133. For estimating the concentration, the experimental method is used in which a grab sample is collected in a 100 ml volumetric standard flask. The activity of gas is then computed by gamma spectrometry using a predetermined efficiency estimated experimentally. An attempt is made using theoretical approach to validate the experimental method of efficiency estimation. Two analytical models named relative flux model and absolute activity model were developed independently of each other. Attention is focussed on the efficiencies for 41 Ar and 133 Xe. Results show that the present method of sampling and analysis using 100 ml volumetric flask is adequate and acceptable. (author). 5 refs., 2 tabs

  3. Study pf apatite accurrence from Gaviao and Serra de Jacabina gold deposit by scintillometry and gamma spectrometry

    International Nuclear Information System (INIS)

    Barreto, P.T.

    1974-01-01

    This work presents the results of radiogeologic reconnaissance in the Cenozoic, Mesozoic and Pre-Cambrian formations, localized between Salvador and Miguel Calmon, and of the radiogeologic detail study from areas of the radioactive anomalies: Gaviao in the Riacho do Lacuipe and Canavieira Mine, in the Jacobina, Bahia States Scintilometry and gamma spectrometry results make possible to conclude by the association, in the Gaviao's apatite mineralization with throrium and the gold of the Serra de Corrego's conglamerate with uranium, make possible in the both case, orient the Search and the mining by scintilometry. The petrographic study and the radiactivity elements dispersion, suggest a sedimentary primary origin to the regional metamorphic rocks. In the Canavieiras mine was evident the stratigraphic control of the gold, associated to uranium and pirite in the conglomerates. (C.D.G.) [pt

  4. High Resolution Powder Diffraction and Structure Determination

    International Nuclear Information System (INIS)

    Cox, D. E.

    1999-01-01

    It is clear that high-resolution synchrotrons X-ray powder diffraction is a very powerful and convenient tool for material characterization and structure determination. Most investigations to date have been carried out under ambient conditions and have focused on structure solution and refinement. The application of high-resolution techniques to increasingly complex structures will certainly represent an important part of future studies, and it has been seen how ab initio solution of structures with perhaps 100 atoms in the asymmetric unit is within the realms of possibility. However, the ease with which temperature-dependence measurements can be made combined with improvements in the technology of position-sensitive detectors will undoubtedly stimulate precise in situ structural studies of phase transitions and related phenomena. One challenge in this area will be to develop high-resolution techniques for ultra-high pressure investigations in diamond anvil cells. This will require highly focused beams and very precise collimation in front of the cell down to dimensions of 50 (micro)m or less. Anomalous scattering offers many interesting possibilities as well. As a means of enhancing scattering contrast it has applications not only to the determination of cation distribution in mixed systems such as the superconducting oxides discussed in Section 9.5.3, but also to the location of specific cations in partially occupied sites, such as the extra-framework positions in zeolites, for example. Another possible application is to provide phasing information for ab initio structure solution. Finally, the precise determination of f as a function of energy through an absorption edge can provide useful information about cation oxidation states, particularly in conjunction with XANES data. In contrast to many experiments at a synchrotron facility, powder diffraction is a relatively simple and user-friendly technique, and most of the procedures and software for data analysis

  5. High resolution CT of the lung

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Harumi (Kyoto Univ. (Japan). Faculty of Medicine)

    1991-02-01

    The emergence of computed tomography (CT) in the early 1970s has greatly contributed to diagnostic radiology. The brain was the first organ examined with CT, followed by the abdomen. For the chest, CT has also come into use shortly after the introduction in the examination of the thoracic cavity and mediastinum. CT techniques were, however, of limited significance in the evaluation of pulmonary diseases, especially diffuse pulmonary diseases. High-resolution CT (HRCT) has been introduced in clinical investigations of the lung field. This article is designed to present chest radiographic and conventional tomographic interpretations and to introduce findings of HRCT corresponding to the same shadows, with a summation of the significance of HRCT and issues of diagnostic imaging. Materials outlined are tuberculosis, pneumoconiosis, bronchopneumonia, mycoplasma pneumonia, lymphangitic carcinomatosis, sarcoidosis, diffuse panbronchiolitis, interstitial pneumonia, and pulmonary emphysema. Finally, an overview of basic investigations evolved from HRCT is given. (N.K.) 140 refs.

  6. Constructing a WISE High Resolution Galaxy Atlas

    Science.gov (United States)

    Jarrett, T. H.; Masci, F.; Tsai, C. W.; Petty, S.; Cluver, M.; Assef, Roberto J.; Benford, D.; Blain, A.; Bridge, C.; Donoso, E.; hide

    2012-01-01

    After eight months of continuous observations, the Wide-field Infrared Survey Explorer (WISE) mapped the entire sky at 3.4 micron, 4.6 micron, 12 micron, and 22 micron. We have begun a dedicated WISE High Resolution Galaxy Atlas project to fully characterize large, nearby galaxies and produce a legacy image atlas and source catalog. Here we summarize the deconvolution techniques used to significantly improve the spatial resolution of WISE imaging, specifically designed to study the internal anatomy of nearby galaxies. As a case study, we present results for the galaxy NGC 1566, comparing the WISE enhanced-resolution image processing to that of Spitzer, Galaxy Evolution Explorer, and ground-based imaging. This is the first paper in a two-part series; results for a larger sample of nearby galaxies are presented in the second paper.

  7. A high resolution jet analysis for LEP

    International Nuclear Information System (INIS)

    Hariri, S.

    1992-11-01

    A high resolution multijet analysis of hadronic events produced in e + e - annihilation at a C.M.S. energy of 91.2 GeV is described. Hadronic events produced in e + e - annihilations are generated using the Monte Carlo program JETSET7.3 with its two options: Matrix Element (M.E.) and Parton Showers (P.S.). The shower option is used with its default parameter values while the M.E. option is used with an invariant mass cut Y CUT =0.01 instead of 0.02. This choice ensures a better continuity in the evolution of the event shape variables. (K.A.) 3 refs.; 26 figs.; 1 tab

  8. High Resolution Displays Using NCAP Liquid Crystals

    Science.gov (United States)

    Macknick, A. Brian; Jones, Phil; White, Larry

    1989-07-01

    Nematic curvilinear aligned phase (NCAP) liquid crystals have been found useful for high information content video displays. NCAP materials are liquid crystals which have been encapsulated in a polymer matrix and which have a light transmission which is variable with applied electric fields. Because NCAP materials do not require polarizers, their on-state transmission is substantially better than twisted nematic cells. All dimensional tolerances are locked in during the encapsulation process and hence there are no critical sealing or spacing issues. By controlling the polymer/liquid crystal morphology, switching speeds of NCAP materials have been significantly improved over twisted nematic systems. Recent work has combined active matrix addressing with NCAP materials. Active matrices, such as thin film transistors, have given displays of high resolution. The paper will discuss the advantages of NCAP materials specifically designed for operation at video rates on transistor arrays; applications for both backlit and projection displays will be discussed.

  9. High resolution VUV facility at INDUS-1

    International Nuclear Information System (INIS)

    Krishnamurty, G.; Saraswathy, P.; Rao, P.M.R.; Mishra, A.P.; Kartha, V.B.

    1993-01-01

    Synchrotron radiation (SR) generated in the electron storage rings is an unique source for the study of atomic and molecular spectroscopy especially in the vacuum ultra violet region. Realizing the potential of this light source, efforts are in progress to develop a beamline facility at INDUS-1 to carry out high resolution atomic and molecular spectroscopy. This beam line consists of a fore-optic which is a combination of three cylindrical mirrors. The mirrors are so chosen that SR beam having a 60 mrad (horizontal) x 6 mrad (vertical) divergence is focussed onto a slit of a 6.65 metre off-plane spectrometer in Eagle Mount equipped with horizontal slit and vertical dispersion. The design of the various components of the beam line is completed. It is decided to build the spectrometer as per the requirements of the user community. Details of the various aspects of the beam line will be presented. (author). 3 figs

  10. High-resolution CT of airway reactivity

    International Nuclear Information System (INIS)

    Herold, C.J.; Brown, R.H.; Hirshman, C.A.; Mitzner, W.; Zerhouni, E.A.

    1990-01-01

    Assessment of airway reactivity has generally been limited to experimental nonimaging models. This authors of this paper used high-resolution CT (HRCT) to evaluate airway reactivity and to calculate airway resistance (Raw) compared with lung resistance (RL). Ten anesthetized and ventilated dogs were investigated with HRCT (10 contiguous 2-mm sections through the lower lung lobes) during control state, following aerosol histamine challenge, and following posthistamine hyperinflation. The HRCT scans were digitized, and areas of 10 airways per dog (diameter, 1-10 mm) were measured with a computer edging process. Changes in airway area and Raw (calculated by 1/[area] 2 ) were measured. RL was assessed separately, following the same protocol. Data were analyzed by use of a paired t-test with significance at p < .05

  11. High resolution crystal calorimetry at LHC

    International Nuclear Information System (INIS)

    Schneegans, M.; Ferrere, D.; Lebeau, M.; Vivargent, M.

    1991-01-01

    The search for Higgs bosons above Lep200 reach could be one of the main tasks of the future pp and ee colliders. In the intermediate mass region, and in particular in the range 80-140 GeV/c 2 , only the 2-photon decay mode of a Higgs produced inclusively or in association with a W, gives a good chance of observation. A 'dedicated' very high resolution calorimeter with photon angle reconstruction and pion identification capability should detect a Higgs signal with high probability. A crystal calorimeter can be considered as a conservative approach to such a detector, since a large design and operation experience already exists. The extensive R and D needed for finding a dense, fast and radiation hard crystal, is under way. Guide-lines for designing an optimum calorimeter for LHC are discussed and preliminary configurations are given. (author) 7 refs., 3 figs., 2 tabs

  12. High resolution tomography using analog coding

    International Nuclear Information System (INIS)

    Brownell, G.L.; Burnham, C.A.; Chesler, D.A.

    1985-01-01

    As part of a 30-year program in the development of positron instrumentation, the authors have developed a high resolution bismuth germanate (BGO) ring tomography (PCR) employing 360 detectors and 90 photomultiplier tubes for one plane. The detectors are shaped as trapezoid and are 4 mm wide at the front end. When assembled, they form an essentially continuous cylindrical detector. Light from a scintillation in the detector is viewed through a cylindrical light pipe by the photomultiplier tubes. By use of an analog coding scheme, the detector emitting light is identified from the phototube signals. In effect, each phototube can identify four crystals. PCR is designed as a static device and does not use interpolative motion. This results in considerable advantage when performing dynamic studies. PCR is the positron tomography analog of the γ-camera widely used in nuclear medicine

  13. High-resolution CT of otosclerosis

    International Nuclear Information System (INIS)

    Dewen, Yang; Kodama, Takao; Tono, Tetsuya; Ochiai, Reiji; Kiyomizu, Kensuke; Suzuki, Yukiko; Yano, Takanori; Watanabe, Katsushi

    1997-01-01

    High-resolution CT (HRCT) scans of thirty-two patients (60 ears) with the clinical diagnosis of fenestral otosclerosis were evaluated retrospectively. HRCT was performed with 1-mm-thick targeted sections and 1-mm (36 ears) or 0.5-mm (10 ears) intervals in the semiaxial projection. Seven patients (14 ears) underwent helical scanning with a 1-mm slice thickness and 1-mm/sec table speed. Forty-five ears (75%) were found to have one or more otospongiotic or otosclerotic foci on HRCT. In most instances (30 ears), the otospongiotic foci were found in the region of the fissula ante fenestram. No significant correlations between CT findings and air conduction threshold were observed. We found a significant relationship between lesions of the labyrinthine capsule and sensorineural hearing loss. We conclude that HRCT is a valuable modality for diagnosing otosclerosis, especially when otospongiotic focus is detected. (author)

  14. High resolution CT in pulmonary sarcoidosis

    International Nuclear Information System (INIS)

    Spina, Juan C.; Curros, Marisela L.; Gomez, M.; Gonzalez, A.; Chacon, Carolina; Guerendiain, G.

    2000-01-01

    Objectives: To establish the particular advantages of High Resolution CT (HRCT) for the diagnosis of pulmonary sarcoidosis. Material and Methods: A series of fourteen patients, (4 men and 10 women; mean age 44,5 years) with thoracic sarcoidosis. All patients were studied using HRCT and diagnosis was confirmed for each case. Confidence intervals were obtained for different disease manifestations. Results: The most common findings were: lymph node enlargement (n=14 patients), pulmonary nodules (n=13), thickening of septa (n=6), peribronquial vascular thickening (n=5) pulmonary pseudo mass (n=5) and signs of fibrosis (n=4). The stage most commonly observed was stage II. It is worth noting that no cases of pleural effusion or cavitations of pulmonary lesions were observed. Conclusions: In this series, confidence interval overlapping for lymph node enlargement, single pulmonary nodules and septum thickening, allows to infer that their presence in a young adult, with few clinical symptoms, forces to rule out first the possibility of sarcoidosis. (author)

  15. Improved methods for high resolution electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, J.R.

    1987-04-01

    Existing methods of making support films for high resolution transmission electron microscopy are investigated and novel methods are developed. Existing methods of fabricating fenestrated, metal reinforced specimen supports (microgrids) are evaluated for their potential to reduce beam induced movement of monolamellar crystals of C/sub 44/H/sub 90/ paraffin supported on thin carbon films. Improved methods of producing hydrophobic carbon films by vacuum evaporation, and improved methods of depositing well ordered monolamellar paraffin crystals on carbon films are developed. A novel technique for vacuum evaporation of metals is described which is used to reinforce microgrids. A technique is also developed to bond thin carbon films to microgrids with a polymer bonding agent. Unique biochemical methods are described to accomplish site specific covalent modification of membrane proteins. Protocols are given which covalently convert the carboxy terminus of papain cleaved bacteriorhodopsin to a free thiol. 53 refs., 19 figs., 1 tab.

  16. High resolution infrared spectroscopy of symbiotic stars

    International Nuclear Information System (INIS)

    Bensammar, S.

    1989-01-01

    We report here very early results of high resolution (5x10 3 - 4x10 4 ) infrared spectroscopy (1 - 2.5 μm) of different symbiotic stars (T CrB, RW Hya, CI Cyg, PU Vul) observed with the Fourier Transform Spectrometer of the 3.60m Canada France Hawaii Telescope. These stars are usually considered as interacting binaries and only little details are known about the nature of their cool component. CO absorption lines are detected for the four stars. Very different profiles of hydrogen Brackett γ and helium 10830 A lines are shown for CI Cyg observed at different phases, while Pu Vul shows very intense emission lines

  17. GRANULOMETRIC MAPS FROM HIGH RESOLUTION SATELLITE IMAGES

    Directory of Open Access Journals (Sweden)

    Catherine Mering

    2011-05-01

    Full Text Available A new method of land cover mapping from satellite images using granulometric analysis is presented here. Discontinuous landscapes such as steppian bushes of semi arid regions and recently growing urban settlements are especially concerned by this study. Spatial organisations of the land cover are quantified by means of the size distribution analysis of the land cover units extracted from high resolution remotely sensed images. A granulometric map is built by automatic classification of every pixel of the image according to the granulometric density inside a sliding neighbourhood. Granulometric mapping brings some advantages over traditional thematic mapping by remote sensing by focusing on fine spatial events and small changes in one peculiar category of the landscape.

  18. Integrated High Resolution Monitoring of Mediterranean vegetation

    Science.gov (United States)

    Cesaraccio, Carla; Piga, Alessandra; Ventura, Andrea; Arca, Angelo; Duce, Pierpaolo; Mereu, Simone

    2017-04-01

    The study of the vegetation features in a complex and highly vulnerable ecosystems, such as Mediterranean maquis, leads to the need of using continuous monitoring systems at high spatial and temporal resolution, for a better interpretation of the mechanisms of phenological and eco-physiological processes. Near-surface remote sensing techniques are used to quantify, at high temporal resolution, and with a certain degree of spatial integration, the seasonal variations of the surface optical and radiometric properties. In recent decades, the design and implementation of global monitoring networks involved the use of non-destructive and/or cheaper approaches such as (i) continuous surface fluxes measurement stations, (ii) phenological observation networks, and (iii) measurement of temporal and spatial variations of the vegetation spectral properties. In this work preliminary results from the ECO-SCALE (Integrated High Resolution Monitoring of Mediterranean vegetation) project are reported. The project was manly aimed to develop an integrated system for environmental monitoring based on digital photography, hyperspectral radiometry , and micrometeorological techniques during three years of experimentation (2013-2016) in a Mediterranean site of Italy (Capo Caccia, Alghero). The main results concerned the analysis of chromatic coordinates indices from digital images, to characterized the phenological patterns for typical shrubland species, determining start and duration of the growing season, and the physiological status in relation to different environmental drought conditions; then the seasonal patterns of canopy phenology, was compared to NEE (Net Ecosystem Exchange) patterns, showing similarities. However, maximum values of NEE and ER (Ecosystem respiration), and short term variation, seemed mainly tuned by inter annual pattern of meteorological variables, in particular of temperature recorded in the months preceding the vegetation green-up. Finally, green signals

  19. High-Resolution Integrated Optical System

    Science.gov (United States)

    Prakapenka, V. B.; Goncharov, A. F.; Holtgrewe, N.; Greenberg, E.

    2017-12-01

    Raman and optical spectroscopy in-situ at extreme high pressure and temperature conditions relevant to the planets' deep interior is a versatile tool for characterization of wide range of properties of minerals essential for understanding the structure, composition, and evolution of terrestrial and giant planets. Optical methods, greatly complementing X-ray diffraction and spectroscopy techniques, become crucial when dealing with light elements. Study of vibrational and optical properties of minerals and volatiles, was a topic of many research efforts in past decades. A great deal of information on the materials properties under extreme pressure and temperature has been acquired including that related to structural phase changes, electronic transitions, and chemical transformations. These provide an important insight into physical and chemical states of planetary interiors (e.g. nature of deep reservoirs) and their dynamics including heat and mass transport (e.g. deep carbon cycle). Optical and vibrational spectroscopy can be also very instrumental for elucidating the nature of the materials molten states such as those related to the Earth's volatiles (CO2, CH4, H2O), aqueous fluids and silicate melts, planetary ices (H2O, CH4, NH3), noble gases, and H2. The optical spectroscopy study performed concomitantly with X-ray diffraction and spectroscopy measurements at the GSECARS beamlines on the same sample and at the same P-T conditions would greatly enhance the quality of this research and, moreover, will provide unique new information on chemical state of matter. The advanced high-resolution user-friendly integrated optical system is currently under construction and expected to be completed by 2018. In our conceptual design we have implemented Raman spectroscopy with five excitation wavelengths (266, 473, 532, 660, 946 nm), confocal imaging, double sided IR laser heating combined with high temperature Raman (including coherent anti-Stokes Raman scattering) and

  20. An analysis of nuclear fuel burnup in the AGR-1 TRISO fuel experiment using gamma spectrometry, mass spectrometry, and computational simulation techniques

    International Nuclear Information System (INIS)

    Harp, Jason M.; Demkowicz, Paul A.; Winston, Philip L.; Sterbentz, James W.

    2014-01-01

    Highlights: • The burnup of irradiated AGR-1 TRISO fuel was analyzed using gamma spectrometry. • The burnup of irradiated AGR-1 TRISO fuel was also analyzed using mass spectrometry. • Agreement between experimental results and neutron physics simulations was excellent. - Abstract: AGR-1 was the first in a series of experiments designed to test US TRISO fuel under high temperature gas-cooled reactor irradiation conditions. This experiment was irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) and is currently undergoing post-irradiation examination (PIE) at INL and Oak Ridge National Laboratory. One component of the AGR-1 PIE is the experimental evaluation of the burnup of the fuel by two separate techniques. Gamma spectrometry was used to non-destructively evaluate the burnup of all 72 of the TRISO fuel compacts that comprised the AGR-1 experiment. Two methods for evaluating burnup by gamma spectrometry were developed, one based on the Cs-137 activity and the other based on the ratio of Cs-134 and Cs-137 activities. Burnup values determined from both methods compared well with the values predicted from simulations. The highest measured burnup was 20.1% FIMA (fissions per initial heavy metal atom) for the direct method and 20.0% FIMA for the ratio method (compared to 19.56% FIMA from simulations). An advantage of the ratio method is that the burnup of the cylindrical fuel compacts can be determined in small (2.5 mm) axial increments and an axial burnup profile can be produced. Destructive chemical analysis by inductively coupled mass spectrometry (ICP-MS) was then performed on selected compacts that were representative of the expected range of fuel burnups in the experiment to compare with the burnup values determined by gamma spectrometry. The compacts analyzed by mass spectrometry had a burnup range of 19.3% FIMA to 10.7% FIMA. The mass spectrometry evaluation of burnup for the four compacts agreed well with the gamma

  1. Dynamic high resolution imaging of rats

    International Nuclear Information System (INIS)

    Miyaoka, R.S.; Lewellen, T.K.; Bice, A.N.

    1990-01-01

    A positron emission tomography with the sensitivity and resolution to do dynamic imaging of rats would be an invaluable tool for biological researchers. In this paper, the authors determine the biological criteria for dynamic positron emission imaging of rats. To be useful, 3 mm isotropic resolution and 2-3 second time binning were necessary characteristics for such a dedicated tomograph. A single plane in which two objects of interest could be imaged simultaneously was considered acceptable. Multi-layered detector designs were evaluated as a possible solution to the dynamic imaging and high resolution imaging requirements. The University of Washington photon history generator was used to generate data to investigate a tomograph's sensitivity to true, scattered and random coincidences for varying detector ring diameters. Intrinsic spatial uniformity advantages of multi-layered detector designs over conventional detector designs were investigated using a Monte Carlo program. As a result, a modular three layered detector prototype is being developed. A module will consist of a layer of five 3.5 mm wide crystals and two layers of six 2.5 mm wide crystals. The authors believe adequate sampling can be achieved with a stationary detector system using these modules. Economical crystal decoding strategies have been investigated and simulations have been run to investigate optimum light channeling methods for block decoding strategies. An analog block decoding method has been proposed and will be experimentally evaluated to determine whether it can provide the desired performance

  2. High resolution computed tomography of positron emitters

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.; Cahoon, J.L.; Huesman, R.H.; Jackson, H.G.

    1976-10-01

    High resolution computed transaxial radionuclide tomography has been performed on phantoms containing positron-emitting isotopes. The imaging system consisted of two opposing groups of eight NaI(Tl) crystals 8 mm x 30 mm x 50 mm deep and the phantoms were rotated to measure coincident events along 8960 projection integrals as they would be measured by a 280-crystal ring system now under construction. The spatial resolution in the reconstructed images is 7.5 mm FWHM at the center of the ring and approximately 11 mm FWHM at a radius of 10 cm. We present measurements of imaging and background rates under various operating conditions. Based on these measurements, the full 280-crystal system will image 10,000 events per sec with 400 μCi in a section 1 cm thick and 20 cm in diameter. We show that 1.5 million events are sufficient to reliably image 3.5-mm hot spots with 14-mm center-to-center spacing and isolated 9-mm diameter cold spots in phantoms 15 to 20 cm in diameter

  3. High speed, High resolution terahertz spectrometers

    International Nuclear Information System (INIS)

    Kim, Youngchan; Yee, Dae Su; Yi, Miwoo; Ahn, Jaewook

    2008-01-01

    A variety of sources and methods have been developed for terahertz spectroscopy during almost two decades. Terahertz time domain spectroscopy (THz TDS)has attracted particular attention as a basic measurement method in the fields of THz science and technology. Recently, asynchronous optical sampling (AOS)THz TDS has been demonstrated, featuring rapid data acquisition and a high spectral resolution. Also, terahertz frequency comb spectroscopy (TFCS)possesses attractive features for high precision terahertz spectroscopy. In this presentation, we report on these two types of terahertz spectrometer. Our high speed, high resolution terahertz spectrometer is demonstrated using two mode locked femtosecond lasers with slightly different repetition frequencies without a mechanical delay stage. The repetition frequencies of the two femtosecond lasers are stabilized by use of two phase locked loops sharing the same reference oscillator. The time resolution of our terahertz spectrometer is measured using the cross correlation method to be 270 fs. AOS THz TDS is presented in Fig. 1, which shows a time domain waveform rapidly acquired on a 10ns time window. The inset shows a zoom into the signal with 100ps time window. The spectrum obtained by the fast Fourier Transformation (FFT)of the time domain waveform has a frequency resolution of 100MHz. The dependence of the signal to noise ratio (SNR)on the measurement time is also investigated

  4. High resolution CT of temporal bone trauma

    International Nuclear Information System (INIS)

    Youn, Eun Kyung

    1986-01-01

    Radiographic studies of the temporal bone following head trauma are indicated when there is cerebrospinal fluid otorrhea or rhinorrhoea, hearing loss, or facial nerve paralysis. Plain radiography displays only 17-30% of temporal bone fractures and pluridirectional tomography is both difficult to perform, particularly in the acutely ill patient, and less satisfactory for the demonstration of fine fractures. Consequently, high resolution CT is the imaging method of choice for the investigation of suspected temporal bone trauma and allows special resolution of fine bony detail comparable to that attainable by conventional tomography. Eight cases of temporal bone trauma examined at Korea General Hospital April 1985 through May 1986. The results were as follows: Seven patients (87%) suffered longitudinal fractures. In 6 patients who had purely conductive hearing loss, CT revealed various ossicular chain abnormality. In one patient who had neuro sensory hearing loss, CT demonstrated intract ossicular with a fracture nearing lateral wall of the lateral semicircular canal. In one patient who had mixed hearing loss, CT showed complex fracture.

  5. High resolution SETI: Experiences and prospects

    Science.gov (United States)

    Horowitz, Paul; Clubok, Ken

    Megachannel spectroscopy with sub-Hertz resolution constitutes an attractive strategy for a microwave search for extraterrestrial intelligence (SETI), assuming the transmission of a narrowband radiofrequency beacon. Such resolution matches the properties of the interstellar medium, and the necessary Doppler corrections provide a high degree of interference rejection. We have constructed a frequency-agile receiver with an FFT-based 8 megachannel digital spectrum analyzer, on-line signal recognition, and multithreshold archiving. We are using it to conduct a meridian transit search of the northern sky at the Harvard-Smithsonian 26-m antenna, with a second identical system scheduled to begin observations in Argentina this month. Successive 400 kHz spectra, at 0.05 Hz resolution, are searched for features characteristic of an intentional narrowband beacon transmission. These spectra are centered on guessable frequencies (such as λ21 cm), referenced successively to the local standard of rest, the galactic barycenter, and the cosmic blackbody rest frame. This search has rejected interference admirably, but is greatly limited both in total frequency coverage and sensitivity to signals other than carriers. We summarize five years of high resolution SETI at Harvard, in the context of answering the questions "How useful is narrowband SETI, how serious are its limitations, what can be done to circumvent them, and in what direction should SETI evolve?" Increasingly powerful signal processing hardware, combined with ever-higher memory densities, are particularly relevant, permitting the construction of compact and affordable gigachannel spectrum analyzers covering hundreds of megahertz of instantaneous bandwidth.

  6. High-resolution CCD imaging alternatives

    Science.gov (United States)

    Brown, D. L.; Acker, D. E.

    1992-08-01

    High resolution CCD color cameras have recently stimulated the interest of a large number of potential end-users for a wide range of practical applications. Real-time High Definition Television (HDTV) systems are now being used or considered for use in applications ranging from entertainment program origination through digital image storage to medical and scientific research. HDTV generation of electronic images offers significant cost and time-saving advantages over the use of film in such applications. Further in still image systems electronic image capture is faster and more efficient than conventional image scanners. The CCD still camera can capture 3-dimensional objects into the computing environment directly without having to shoot a picture on film develop it and then scan the image into a computer. 2. EXTENDING CCD TECHNOLOGY BEYOND BROADCAST Most standard production CCD sensor chips are made for broadcast-compatible systems. One popular CCD and the basis for this discussion offers arrays of roughly 750 x 580 picture elements (pixels) or a total array of approximately 435 pixels (see Fig. 1). FOR. A has developed a technique to increase the number of available pixels for a given image compared to that produced by the standard CCD itself. Using an inter-lined CCD with an overall spatial structure several times larger than the photo-sensitive sensor areas each of the CCD sensors is shifted in two dimensions in order to fill in spatial gaps between adjacent sensors.

  7. High resolution simultaneous measurements of airborne radionuclides

    International Nuclear Information System (INIS)

    Abe, T.; Yamaguchi, Y.; Tanaka, K.; Komura, K.

    2006-01-01

    High resolution (2-3 hrs) simultaneous measurements of airborne radionuclides, 212 Pb, 210 Pb and 7 Be, have been performed by using extremely low background Ge detectors at Ogoya Underground Laboratory. We have measured above radionuclides at three monitoring points viz, 1) Low Level Radioactivity Laboratory (LLRL) Kanazawa University, 2) Shishiku Plateau (640 m MSL) located about 8 km from LLRL to investigate vertical difference of activity levels, and 3) Hegura Island (10 m MSL) located about 50 km from Noto Peninsula in the Sea of Japan to evaluate the influences of Asian continent or mainland of Japan on the variation to the activity levels. Variations of short-lived 212 Pb concentration showed noticeable time lags between at LLRL and at Shishiku Plateau. These time lags might be caused by change of height of a planetary boundary layer. On the contrary, variations of long-lived 210 Pb and 7 Be showed simultaneity at three locations because of homogeneity of these concentrations all over the area. (author)

  8. High-resolution X-ray television and high-resolution video recorders

    International Nuclear Information System (INIS)

    Haendle, J.; Horbaschek, H.; Alexandrescu, M.

    1977-01-01

    The improved transmission properties of the high-resolution X-ray television chain described here make it possible to transmit more information per television image. The resolution in the fluoroscopic image, which is visually determined, depends on the dose rate and the inertia of the television pick-up tube. This connection is discussed. In the last few years, video recorders have been increasingly used in X-ray diagnostics. The video recorder is a further quality-limiting element in X-ray television. The development of function patterns of high-resolution magnetic video recorders shows that this quality drop may be largely overcome. The influence of electrical band width and number of lines on the resolution in the X-ray television image stored is explained in more detail. (orig.) [de

  9. Processing method for high resolution monochromator

    International Nuclear Information System (INIS)

    Kiriyama, Koji; Mitsui, Takaya

    2006-12-01

    A processing method for high resolution monochromator (HRM) has been developed at Japanese Atomic Energy Agency/Quantum Beam Science Directorate/Synchrotron Radiation Research unit at SPring-8. For manufacturing a HRM, a sophisticated slicing machine and X-ray diffractometer have been installed for shaping a crystal ingot and orienting precisely the surface of a crystal ingot, respectively. The specification of the slicing machine is following; Maximum size of a diamond blade is φ 350mm in diameter, φ 38.1mm in the spindle diameter, and 2mm in thickness. A large crystal such as an ingot with 100mm in diameter, 200mm in length can be cut. Thin crystal samples such as a wafer can be also cut using by another sample holder. Working distance of a main shaft with the direction perpendicular to working table in the machine is 350mm at maximum. Smallest resolution of the main shaft with directions of front-and-back and top-and-bottom are 0.001mm read by a digital encoder. 2mm/min can set for cutting samples in the forward direction. For orienting crystal faces relative to the blade direction adjustment, a one-circle goniometer and 2-circle segment are equipped on the working table in the machine. A rotation and a tilt of the stage can be done by manual operation. Digital encoder in a turn stage is furnished and has angle resolution of less than 0.01 degrees. In addition, a hand drill as a supporting device for detailed processing of crystal is prepared. Then, an ideal crystal face can be cut from crystal samples within an accuracy of about 0.01 degrees. By installation of these devices, a high energy resolution monochromator crystal for inelastic x-ray scattering and a beam collimator are got in hand and are expected to be used for nanotechnology studies. (author)

  10. Zeolites - a high resolution electron microscopy study

    International Nuclear Information System (INIS)

    Alfredsson, V.

    1994-10-01

    High resolution transmission electron microscopy (HRTEM) has been used to investigate a number of zeolites (EMT, FAU, LTL, MFI and MOR) and a member of the mesoporous M41S family. The electron optical artefact, manifested as a dark spot in the projected centre of the large zeolite channels, caused by insufficient transfer of certain reflections in the objective lens has been explained. The artefact severely hinders observation of materials confined in the zeolite channels and cavities. It is shown how to circumvent the artefact problem and how to image confined materials in spite of disturbance caused by the artefact. Image processing by means of a Wiener filter has been applied for removal of the artefact. The detailed surface structure of FAU has been investigated. Comparison of experimental micrographs with images simulated using different surface models indicates that the surface can be terminated in different ways depending on synthesis methods. The dealuminated form of FAU (USY) is covered by an amorphous region. Platinum incorporated in FAU has a preponderance to aggregate in the (111) twin planes, probably due to a local difference in cage structure with more spacious cages. It is shown that platinum is intra-zeolitic as opposed to being located on the external surface of the zeolite crystal. This could be deduced from tomography of ultra-thin sections among observations. HRTEM studies of the mesoporous MCM-41 show that the pores have a hexagonal shape and also supports the mechanistic model proposed which involves a cooperative formation of a mesophase including the silicate species as well as the surfactant. 66 refs, 24 figs

  11. High-resolution downscaling for hydrological management

    Science.gov (United States)

    Ulbrich, Uwe; Rust, Henning; Meredith, Edmund; Kpogo-Nuwoklo, Komlan; Vagenas, Christos

    2017-04-01

    Hydrological modellers and water managers require high-resolution climate data to model regional hydrologies and how these may respond to future changes in the large-scale climate. The ability to successfully model such changes and, by extension, critical infrastructure planning is often impeded by a lack of suitable climate data. This typically takes the form of too-coarse data from climate models, which are not sufficiently detailed in either space or time to be able to support water management decisions and hydrological research. BINGO (Bringing INnovation in onGOing water management; ) aims to bridge the gap between the needs of hydrological modellers and planners, and the currently available range of climate data, with the overarching aim of providing adaptation strategies for climate change-related challenges. Producing the kilometre- and sub-daily-scale climate data needed by hydrologists through continuous simulations is generally computationally infeasible. To circumvent this hurdle, we adopt a two-pronged approach involving (1) selective dynamical downscaling and (2) conditional stochastic weather generators, with the former presented here. We take an event-based approach to downscaling in order to achieve the kilometre-scale input needed by hydrological modellers. Computational expenses are minimized by identifying extremal weather patterns for each BINGO research site in lower-resolution simulations and then only downscaling to the kilometre-scale (convection permitting) those events during which such patterns occur. Here we (1) outline the methodology behind the selection of the events, and (2) compare the modelled precipitation distribution and variability (preconditioned on the extremal weather patterns) with that found in observations.

  12. Toward high-resolution optoelectronic retinal prosthesis

    Science.gov (United States)

    Palanker, Daniel; Huie, Philip; Vankov, Alexander; Asher, Alon; Baccus, Steven

    2005-04-01

    It has been already demonstrated that electrical stimulation of retina can produce visual percepts in blind patients suffering from macular degeneration and retinitis pigmentosa. Current retinal implants provide very low resolution (just a few electrodes), while several thousand pixels are required for functional restoration of sight. We present a design of the optoelectronic retinal prosthetic system that can activate a retinal stimulating array with pixel density up to 2,500 pix/mm2 (geometrically corresponding to a visual acuity of 20/80), and allows for natural eye scanning rather than scanning with a head-mounted camera. The system operates similarly to "virtual reality" imaging devices used in military and medical applications. An image from a video camera is projected by a goggle-mounted infrared LED-LCD display onto the retina, activating an array of powered photodiodes in the retinal implant. Such a system provides a broad field of vision by allowing for natural eye scanning. The goggles are transparent to visible light, thus allowing for simultaneous utilization of remaining natural vision along with prosthetic stimulation. Optical control of the implant allows for simple adjustment of image processing algorithms and for learning. A major prerequisite for high resolution stimulation is the proximity of neural cells to the stimulation sites. This can be achieved with sub-retinal implants constructed in a manner that directs migration of retinal cells to target areas. Two basic implant geometries are described: perforated membranes and protruding electrode arrays. Possibility of the tactile neural stimulation is also examined.

  13. High-resolution phylogenetic microbial community profiling

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Esther; Coleman-Derr, Devin; Bowman, Brett; Schwientek, Patrick; Clum, Alicia; Copeland, Alex; Ciobanu, Doina; Cheng, Jan-Fang; Gies, Esther; Hallam, Steve; Tringe, Susannah; Woyke, Tanja

    2014-03-17

    The representation of bacterial and archaeal genome sequences is strongly biased towards cultivated organisms, which belong to merely four phylogenetic groups. Functional information and inter-phylum level relationships are still largely underexplored for candidate phyla, which are often referred to as microbial dark matter. Furthermore, a large portion of the 16S rRNA gene records in the GenBank database are labeled as environmental samples and unclassified, which is in part due to low read accuracy, potential chimeric sequences produced during PCR amplifications and the low resolution of short amplicons. In order to improve the phylogenetic classification of novel species and advance our knowledge of the ecosystem function of uncultivated microorganisms, high-throughput full length 16S rRNA gene sequencing methodologies with reduced biases are needed. We evaluated the performance of PacBio single-molecule real-time (SMRT) sequencing in high-resolution phylogenetic microbial community profiling. For this purpose, we compared PacBio and Illumina metagenomic shotgun and 16S rRNA gene sequencing of a mock community as well as of an environmental sample from Sakinaw Lake, British Columbia. Sakinaw Lake is known to contain a large age of microbial species from candidate phyla. Sequencing results show that community structure based on PacBio shotgun and 16S rRNA gene sequences is highly similar in both the mock and the environmental communities. Resolution power and community representation accuracy from SMRT sequencing data appeared to be independent of GC content of microbial genomes and was higher when compared to Illumina-based metagenome shotgun and 16S rRNA gene (iTag) sequences, e.g. full-length sequencing resolved all 23 OTUs in the mock community, while iTags did not resolve closely related species. SMRT sequencing hence offers various potential benefits when characterizing uncharted microbial communities.

  14. Comparison of SensL and Hamamatsu 4×4 channel SiPM arrays in gamma spectrometry with scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Grodzicka-Kobylka, M., E-mail: m.grodzicka@ncbj.gov.pl; Szczesniak, T.; Moszyński, M.

    2017-06-01

    The market of Silicon Photomultipliers (SiPMs) consists of many manufacturers that produce their detectors in different technology. Hamamatsu (Japan) and SensL (Ireland) seems to be the most popular companies that produce large SiPM arrays. The aim of this work is characterization and comparison of 4×4 channel SiPM arrays produced by these two producers. Both of the tested SiPMs are made in through-silicon via (TSV) technology, consist of 16, 3×3 mm avalanche photodiode (APD) cells and have fill factor slightly above 60%. The largest difference is a single APD cell size and hence total number of APD cells (55,424 for Hamamatsu, 76,640 for SensL). In the case of SensL SiPM, its spectral response characteristics is shifted slightly toward shorter wavelengths with maximum at 420 nm (450 nm for Hamamatsu). The presented measurements cover selection of the SiPM optimum operating voltage (in respect to energy resolution), verification of the excess noise factor and check of the linearity characteristics. Moreover, the gamma spectrometry with LSO, BGO and CsI:Tl scintillators together with pulse characteristics for these crystals (rise time and fall time) is reported, as well as temperature dependence. The presented measurements show better performance of the SensL array comparing to the Hamamatsu detector.

  15. Field GE gamma spectrometry for on site measurements of some parameters characterizing radon-222 exhalation rates from soils and covers

    International Nuclear Information System (INIS)

    Zettwoog, P.; Kobal, I.; Pineau, J.F.

    1997-01-01

    We describe a new method based on differential gamma spectrometry for on site determination of some of the parameters which are relevant for the production of radon 222 in soil gas and its transfer from soil to indoor and outdoor atmospheres. This method is investigated in the context of a 3-year Slovenian-French cooperation programme, the PROTEUS project. We are currently using a germanium detector of 100 cm 3 . The height of the 20 deg. C collimated detector above the soil surface is from 1.5 to 3 m when using a tripod. This arrangement provides results which are representative of soil areas ranging from 1 to 4 square metres. Routine measurements would require larger detector volumes. The main objective is to provide technology and methodology for an efficient mapping of zones with potential for being the source of a high level of indoor radon, eliminating the need for soil sampling followed by laboratory analysis. The feasibility of an airborne mapping laboratory flying at low altitude will be investigated. Another objective is the rapid measurement of radon profiles across covers used to reduce exhalation rates from the surface of a pile of tailings, with characterisation of the influence of humidity content of the top layer. Airborne survey would allow for measuring exhalations from surfaces of slurries not otherwise accessible. (author)

  16. Measurement of radionuclide activities of uranium-238 series in soil samples by gamma spectrometry: case of Vinaninkarena

    International Nuclear Information System (INIS)

    Randrianantenaina, F.R.

    2017-01-01

    The aim of this work is to determine the activity level of radionuclides of uranium-238 series. Eight soil samples are collected at Rural Commune of Vinaninkarena. After obtaining secular equilibrium, these samples have been measured using gamma spectrometry system in the Nuclear Analyses and Techniques Department of INSTN-Madagascar, with HPGe detector (30 % relative efficiency) and a Genie 2000 software. Activities obtained vary from (78±2)Bq.kg -1 to (49 231 ± 415)Bq.kg -1 . Among these eight samples, three activity levels are shown. Low activity is an activity which has value lower or equal to (89±3)Bq.kg -1 . Average activity is an activity which has value between (186± 1)Bq.kg -1 and (1049 ±7)Bq.kg -1 . And high activity is an activity which has value higher or equal to (14501±209)Bq.kg -1 . According to UNSCEAR 2000, these value are all higher than the world average value which is 35 Bq.kg -1 .It is due to the localities of sampling points. The variation of the activity level depends on radionuclide concentration of uranium-238 series in the soil. [fr

  17. Iodine 129 measurements by gamma spectrometry in biological samples. Results in seaweeds (Fucus serratus et laminaria digitata)

    International Nuclear Information System (INIS)

    Maro, D.; Hebert, D.; Gandon, R.; Solier, L.

    1999-01-01

    A iodine selective radiochemistry method was developed to measure 129 I(period 1,57 x 10 10 7 years) by gamma spectrometry in biological samples. This method avoids using neutron activation analysis or accelerator mass spectrometry. The method is based on iodine extraction from samples in order to obtain an aqueous matrix with no attenuation agent except 127 I(stable isotope). The parallel determination of 127 I allows to correct 129 I measurements for self attenuation and also monitor seasonal changes in iodine metabolism in biological species. Measurements were performed in two seaweed species (Fucus serratus and Laminaria digitata) samples in the area of La Hague reprocessing plant discharge between January and February 1997). Samples from stations close to the point of release (Goury and Herquemoulin), showed 129 I activities around 60 Bq kg -1 dry weight in Fucus serratus and around 300 Bq kg -1 dry weight in Laminaria digitata. 300 km away from the realize point, 129 I activities were 10 Bq kg -1 dry weight in Fucus serratus and 171 Bq kg -1 dry weight in Laminaria digitata. 127 I concentrations were between 547 and 1,232 mg kg -1 dry weight in Fucus serratus and between 6,624 and 14,296 mg kg -1 dry weight in Laminaria digitata. (authors)

  18. Constrains in gamma spectrometry analysis of fallout 137Cs in coastal marine environment of Arabian sea in India

    International Nuclear Information System (INIS)

    Sartandel, S.J.; Jha, S.K.; Puranik, V.D.

    2012-01-01

    In this study, an accurate faster gamma spectrometry method for measuring the low level activity concentrations of 137 Cs using in situ pre-concentration technique on copper ferrocyanide cartridge was standardized. Due to unavailability of reference standard in the copper ferrocyanide matrix, efficiency calibration curves were plotted using RGU and RGTh reference standards. To harmonize the difference in density of standard and sample the required density correction factors for photo peak efficiency were generated. The in situ pre-concentration technique followed by gamma-ray spectrometry was applied for activity determination in surface seawater from eight locations in the coastal marine environment of Arabian Sea. The mean activity concentration of 137 Cs ranged between 0.71 and 0.91 Bq/m 3 . Higher activity concentrations were observed at location with latitude, longitude of 21.6 deg N, 69.57 deg E as compared to concentration observed at location with latitude, longitude 16.98 deg N, 73.25 deg E. The observed concentrations were found to be in range of data reported in Asia-Pacific Marine radioactive database (ASPARMARD). The results will fill up the gaps in the existing database. The generated data will be useful for monitoring fresh input of anthropogenic radionuclide into coastal marine environment for post Fukushima environmental assessment. (author)

  19. A comparative study of 232Th and 238U activity estimation in soil samples by gamma spectrometry and Neutron Activation Analysis (NAA) technique

    International Nuclear Information System (INIS)

    Rekha, A.K.; Anilkumar, S.; Narayani, K.; Babu, D.A.R.

    2012-01-01

    Radioactivity in the environment is mainly due to the naturally occurring radionuclides like uranium, thorium with their daughter products and potassium. Even though Gamma spectrometry is the most commonly used non destructive method for the quantification of these naturally occurring radionuclides, Neutron Activation Analysis (NAA), a well established analytical technique, can also be used. But the NAA technique is a time consuming process and needs proper standards, proper sample preparation etc. In this paper, the 232 Th and 238 U activity estimated using gamma ray spectrometry and NAA technique are compared. In the case of direct gamma spectrometry method, the samples were analysed after sealing in a 250 ml container. Whereas for the NAA, about 300 mg of each sample, after irradiation were subjected to gamma spectrometry. The 238 U and 232 Th activities (in Bq/kg) in samples were estimated after the proper efficiency correction and were compared. The estimated activities by these two methods are in good agreement. The variation in 238 U and 232 Th activity values are within ± 15% which are acceptable for environmental samples

  20. HIGH RESOLUTION AIRBORNE SHALLOW WATER MAPPING

    Directory of Open Access Journals (Sweden)

    F. Steinbacher

    2012-07-01

    Full Text Available In order to meet the requirements of the European Water Framework Directive (EU-WFD, authorities face the problem of repeatedly performing area-wide surveying of all kinds of inland waters. Especially for mid-sized or small rivers this is a considerable challenge imposing insurmountable logistical efforts and costs. It is therefore investigated if large-scale surveying of a river system on an operational basis is feasible by employing airborne hydrographic laser scanning. In cooperation with the Bavarian Water Authority (WWA Weilheim a pilot project was initiated by the Unit of Hydraulic Engineering at the University of Innsbruck and RIEGL Laser Measurement Systems exploiting the possibilities of a new LIDAR measurement system with high spatial resolution and high measurement rate to capture about 70 km of riverbed and foreland for the river Loisach in Bavaria/Germany and the estuary and parts of the shoreline (about 40km in length of lake Ammersee. The entire area surveyed was referenced to classic terrestrial cross-section surveys with the aim to derive products for the monitoring and managing needs of the inland water bodies forced by the EU-WFD. The survey was performed in July 2011 by helicopter and airplane and took 3 days in total. In addition, high resolution areal images were taken to provide an optical reference, offering a wide range of possibilities on further research, monitoring, and managing responsibilities. The operating altitude was about 500 m to maintain eye-safety, even for the aided eye, the airspeed was about 55 kts for the helicopter and 75 kts for the aircraft. The helicopter was used in the alpine regions while the fixed wing aircraft was used in the plains and the urban area, using appropriate scan rates to receive evenly distributed point clouds. The resulting point density ranged from 10 to 25 points per square meter. By carefully selecting days with optimum water quality, satisfactory penetration down to the river

  1. High Resolution Airborne Shallow Water Mapping

    Science.gov (United States)

    Steinbacher, F.; Pfennigbauer, M.; Aufleger, M.; Ullrich, A.

    2012-07-01

    In order to meet the requirements of the European Water Framework Directive (EU-WFD), authorities face the problem of repeatedly performing area-wide surveying of all kinds of inland waters. Especially for mid-sized or small rivers this is a considerable challenge imposing insurmountable logistical efforts and costs. It is therefore investigated if large-scale surveying of a river system on an operational basis is feasible by employing airborne hydrographic laser scanning. In cooperation with the Bavarian Water Authority (WWA Weilheim) a pilot project was initiated by the Unit of Hydraulic Engineering at the University of Innsbruck and RIEGL Laser Measurement Systems exploiting the possibilities of a new LIDAR measurement system with high spatial resolution and high measurement rate to capture about 70 km of riverbed and foreland for the river Loisach in Bavaria/Germany and the estuary and parts of the shoreline (about 40km in length) of lake Ammersee. The entire area surveyed was referenced to classic terrestrial cross-section surveys with the aim to derive products for the monitoring and managing needs of the inland water bodies forced by the EU-WFD. The survey was performed in July 2011 by helicopter and airplane and took 3 days in total. In addition, high resolution areal images were taken to provide an optical reference, offering a wide range of possibilities on further research, monitoring, and managing responsibilities. The operating altitude was about 500 m to maintain eye-safety, even for the aided eye, the airspeed was about 55 kts for the helicopter and 75 kts for the aircraft. The helicopter was used in the alpine regions while the fixed wing aircraft was used in the plains and the urban area, using appropriate scan rates to receive evenly distributed point clouds. The resulting point density ranged from 10 to 25 points per square meter. By carefully selecting days with optimum water quality, satisfactory penetration down to the river bed was achieved

  2. High resolution time integration for SN radiation transport

    International Nuclear Information System (INIS)

    Thoreson, Greg; McClarren, Ryan G.; Chang, Jae H.

    2009-01-01

    First-order, second-order, and high resolution time discretization schemes are implemented and studied for the discrete ordinates (S N ) equations. The high resolution method employs a rate of convergence better than first-order, but also suppresses artificial oscillations introduced by second-order schemes in hyperbolic partial differential equations. The high resolution method achieves these properties by nonlinearly adapting the time stencil to use a first-order method in regions where oscillations could be created. We employ a quasi-linear solution scheme to solve the nonlinear equations that arise from the high resolution method. All three methods were compared for accuracy and convergence rates. For non-absorbing problems, both second-order and high resolution converged to the same solution as the first-order with better convergence rates. High resolution is more accurate than first-order and matches or exceeds the second-order method

  3. A high resolution solar atlas for fluorescence calculations

    Science.gov (United States)

    Hearn, M. F.; Ohlmacher, J. T.; Schleicher, D. G.

    1983-01-01

    The characteristics required of a solar atlas to be used for studying the fluorescence process in comets are examined. Several sources of low resolution data were combined to provide an absolutely calibrated spectrum from 2250 A to 7000A. Three different sources of high resolution data were also used to cover this same spectral range. The low resolution data were then used to put each high resolution spectrum on an absolute scale. The three high resolution spectra were then combined in their overlap regions to produce a single, absolutely calibrated high resolution spectrum over the entire spectral range.

  4. High resolution time integration for Sn radiation transport

    International Nuclear Information System (INIS)

    Thoreson, Greg; McClarren, Ryan G.; Chang, Jae H.

    2008-01-01

    First order, second order and high resolution time discretization schemes are implemented and studied for the S n equations. The high resolution method employs a rate of convergence better than first order, but also suppresses artificial oscillations introduced by second order schemes in hyperbolic differential equations. All three methods were compared for accuracy and convergence rates. For non-absorbing problems, both second order and high resolution converged to the same solution as the first order with better convergence rates. High resolution is more accurate than first order and matches or exceeds the second order method. (authors)

  5. Airborne gamma spectrometry measurements in the context of the exercise ARM02; Aeroradiometrische Messungen im Rahmen der Uebung ARM02

    Energy Technology Data Exchange (ETDEWEB)

    Bucher, B.; Rybach, L. [ETH Zuerich (Switzerland); Schwarz, G. [Swiss Nuclear Safety Authority, Villigen (Switzerland); Baerlocher, C. [ETH Zuerich (Switzerland)

    2003-05-01

    The international exercise under the European Union project ECCOMAGS (European Coordination and Calibration of Mobile and Airborne Gamma Spectrometry) stood in the centre of the yearly airborne gamma spectrometry measurement flights which were carried out in the time of 27 -31 May 2002. The exercise was held in Southwest Scotland in the region of Dumfries and Galloway. Unfortunately due to difficulties with flight approvals for military aircrafts data could be taken in the exercise area only on the flight back to Switzerland. Immediately after returning to Switzerland the regular measurements around the nuclear power plants Beznau (KKB) and Leibstadt (KKL), around the intermediate storage facilities for radioactive waste (ZWILAG) and around the research facility Paul Scherrer Institute were performed. The flights took place in the context of the exercise ARM02 and were lead by the Swiss National Emergency Operations Centre (NAZ). Unfortunately just a few measurements in the common intercalibration areas could be taken on the flight back from the international exercise. Nevertheless comparisons of the results with those of other European teams could be made. These comparisons proved the good calibration of our equipment. On the flight back measurements were also carried out at great altitude above the sea. This data allowed to determine very well the background of the aircraft and the cosmic stripping ratios. In the context of the regular measurements in the environs of the nuclear facilities in Switzerland the areas around the nuclear power plants Beznau and Leibstadt and around the nuclear research facility Paul Scherrer Institute were measured. The results were very similar to the results of earlier measurements in the last years. The nuclear power plant Beznau couldn't be recognised on the activity maps. But the nuclear power plant Leibstadt could be identified by its direct radiation which is specific for this type of reactor (BWR). At the site of the Paul

  6. Scalable Algorithms for Large High-Resolution Terrain Data

    DEFF Research Database (Denmark)

    Mølhave, Thomas; Agarwal, Pankaj K.; Arge, Lars Allan

    2010-01-01

    In this paper we demonstrate that the technology required to perform typical GIS computations on very large high-resolution terrain models has matured enough to be ready for use by practitioners. We also demonstrate the impact that high-resolution data has on common problems. To our knowledge, so...

  7. High-resolution X-ray diffraction studies of multilayers

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Hornstrup, Allan; Schnopper, H. W.

    1988-01-01

    High-resolution X-ray diffraction studies of the perfection of state-of-the-art multilayers are presented. Data were obtained using a triple-axis perfect-crystal X-ray diffractometer. Measurements reveal large-scale figure errors in the substrate. A high-resolution triple-axis set up is required...

  8. Achieving sensitive, high-resolution laser spectroscopy at CRIS

    Energy Technology Data Exchange (ETDEWEB)

    Groote, R. P. de [Instituut voor Kern- en Stralingsfysica, KU Leuven (Belgium); Lynch, K. M., E-mail: kara.marie.lynch@cern.ch [EP Department, CERN, ISOLDE (Switzerland); Wilkins, S. G. [The University of Manchester, School of Physics and Astronomy (United Kingdom); Collaboration: the CRIS collaboration

    2017-11-15

    The Collinear Resonance Ionization Spectroscopy (CRIS) experiment, located at the ISOLDE facility, has recently performed high-resolution laser spectroscopy, with linewidths down to 20 MHz. In this article, we present the modifications to the beam line and the newly-installed laser systems that have made sensitive, high-resolution measurements possible. Highlights of recent experimental campaigns are presented.

  9. High resolution UV spectroscopy and laser-focused nanofabrication

    NARCIS (Netherlands)

    Myszkiewicz, G.

    2005-01-01

    This thesis combines two at first glance different techniques: High Resolution Laser Induced Fluorescence Spectroscopy (LIF) of small aromatic molecules and Laser Focusing of atoms for Nanofabrication. The thesis starts with the introduction to the high resolution LIF technique of small aromatic

  10. High resolution NMR spectroscopy of synthetic polymers in bulk

    International Nuclear Information System (INIS)

    Komorski, R.A.

    1986-01-01

    The contents of this book are: Overview of high-resolution NMR of solid polymers; High-resolution NMR of glassy amorphous polymers; Carbon-13 solid-state NMR of semicrystalline polymers; Conformational analysis of polymers of solid-state NMR; High-resolution NMR studies of oriented polymers; High-resolution solid-state NMR of protons in polymers; and Deuterium NMR of solid polymers. This work brings together the various approaches for high-resolution NMR studies of bulk polymers into one volume. Heavy emphasis is, of course, given to 13C NMR studies both above and below Tg. Standard high-power pulse and wide-line techniques are not covered

  11. The advantage of using the henry straight line in {gamma} spectrometry (1963); Interet de l'utilisation de la droite de henry en spectrometrie {gamma} (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Jockey, [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The Henry construction is a convenient way to interpret the total absorption peaks in gamma spectrometry by exploiting their statistical significance. It is so possible to determine graphically, and accurately, such values as: - position of the peak - resolution, etc. The main practical applications are considered. (author) [French] La construction de la droite de Henry fournit un moyen commode d'interpreter les pics d'absorption totale en spectrometrie gamma en exploitant leur signification statistique, il est ainsi possible de determiner graphiquement, avec precision, des notions telles que: - position du pic - resolution, etc. Les principales applications pratiques sont envisagees. (auteur)

  12. Theoretical determination of gamma spectrometry systems efficiency based on probability functions. Application to self-attenuation correction factors

    Energy Technology Data Exchange (ETDEWEB)

    Barrera, Manuel, E-mail: manuel.barrera@uca.es [Escuela Superior de Ingeniería, University of Cadiz, Avda, Universidad de Cadiz 10, 11519 Puerto Real, Cadiz (Spain); Suarez-Llorens, Alfonso [Facultad de Ciencias, University of Cadiz, Avda, Rep. Saharaui s/n, 11510 Puerto Real, Cadiz (Spain); Casas-Ruiz, Melquiades; Alonso, José J.; Vidal, Juan [CEIMAR, University of Cadiz, Avda, Rep. Saharaui s/n, 11510 Puerto Real, Cádiz (Spain)

    2017-05-11

    A generic theoretical methodology for the calculation of the efficiency of gamma spectrometry systems is introduced in this work. The procedure is valid for any type of source and detector and can be applied to determine the full energy peak and the total efficiency of any source-detector system. The methodology is based on the idea of underlying probability of detection, which describes the physical model for the detection of the gamma radiation at the particular studied situation. This probability depends explicitly on the direction of the gamma radiation, allowing the use of this dependence the development of more realistic and complex models than the traditional models based on the point source integration. The probability function that has to be employed in practice must reproduce the relevant characteristics of the detection process occurring at the particular studied situation. Once the probability is defined, the efficiency calculations can be performed in general by using numerical methods. Monte Carlo integration procedure is especially useful to perform the calculations when complex probability functions are used. The methodology can be used for the direct determination of the efficiency and also for the calculation of corrections that require this determination of the efficiency, as it is the case of coincidence summing, geometric or self-attenuation corrections. In particular, we have applied the procedure to obtain some of the classical self-attenuation correction factors usually employed to correct for the sample attenuation of cylindrical geometry sources. The methodology clarifies the theoretical basis and approximations associated to each factor, by making explicit the probability which is generally hidden and implicit to each model. It has been shown that most of these self-attenuation correction factors can be derived by using a common underlying probability, having this probability a growing level of complexity as it reproduces more precisely

  13. Gamma spectrometry; level schemes

    International Nuclear Information System (INIS)

    Blachot, J.; Bocquet, J.P.; Monnand, E.; Schussler, F.

    1977-01-01

    The research presented dealt with: a new beta emitter, isomer of 131 Sn; the 136 I levels fed through the radioactive decay of 136 Te (20.9s); the A=145 chain (β decay of Ba, La and Ce, and level schemes for 145 La, 145 Ce, 145 Pr); the A=47 chain (La and Ce, β decay, and the level schemes of 147 Ce and 147 Pr) [fr

  14. Gamma spectrometry today

    International Nuclear Information System (INIS)

    Hemingway, J.

    1990-01-01

    This paper reviews the important advances in gamma spectroscopy made in recent years. Improvements in detectors and other components and the addition of on-line computer control systems is discussed. (UK)

  15. A Forward-Looking High-Resolution GPR System

    National Research Council Canada - National Science Library

    Kositsky, Joel; Milanfar, Peyman

    1999-01-01

    A high-resolution ground penetrating radar (GPR) system was designed to help define the optimal radar parameters needed for the efficient standoff detection of buried and surface-laid antitank mines...

  16. High-resolution seismic wave propagation using local time stepping

    KAUST Repository

    Peter, Daniel; Rietmann, Max; Galvez, Percy; Ampuero, Jean Paul

    2017-01-01

    High-resolution seismic wave simulations often require local refinements in numerical meshes to accurately capture e.g. steep topography or complex fault geometry. Together with explicit time schemes, this dramatically reduces the global time step

  17. Impact of high resolution land surface initialization in Indian summer ...

    Indian Academy of Sciences (India)

    The direct impact of high resolution land surface initialization on the forecast bias in a regional climate model in recent years ... surface initialization using a regional climate model. ...... ization of the snow field in a cloud model; J. Clim. Appl.

  18. Textural Segmentation of High-Resolution Sidescan Sonar Images

    National Research Council Canada - National Science Library

    Kalcic, Maria; Bibee, Dale

    1995-01-01

    .... The high resolution of the 455 kHz sonar imagery also provides much information about the surficial bottom sediments, however their acoustic scattering properties are not well understood at high frequencies...

  19. NOAA High-Resolution Sea Surface Temperature (SST) Analysis Products

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This archive covers two high resolution sea surface temperature (SST) analysis products developed using an optimum interpolation (OI) technique. The analyses have a...

  20. Hurricane Satellite (HURSAT) from Advanced Very High Resolution Radiometer (AVHRR)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Huricane Satellite (HURSAT)-Advanced Very High Resolution Radiometer (AVHRR) is used to extend the HURSAT data set such that appling the Objective Dvorak technique...

  1. NanoComposite Polymers for High Resolution Near Infrared Detectors

    Data.gov (United States)

    National Aeronautics and Space Administration — Develop nanocomposite materials with tuned refractive index in the near infra red spectral range as an index-matched immersion lens for high resolution infra-red...

  2. Methodology of high-resolution photography for mural condition database

    Science.gov (United States)

    Higuchi, R.; Suzuki, T.; Shibata, M.; Taniguchi, Y.

    2015-08-01

    Digital documentation is one of the most useful techniques to record the condition of cultural heritage. Recently, high-resolution images become increasingly useful because it is possible to show general views of mural paintings and also detailed mural conditions in a single image. As mural paintings are damaged by environmental stresses, it is necessary to record the details of painting condition on high-resolution base maps. Unfortunately, the cost of high-resolution photography and the difficulty of operating its instruments and software have commonly been an impediment for researchers and conservators. However, the recent development of graphic software makes its operation simpler and less expensive. In this paper, we suggest a new approach to make digital heritage inventories without special instruments, based on our recent our research project in Üzümlü church in Cappadocia, Turkey. This method enables us to achieve a high-resolution image database with low costs, short time, and limited human resources.

  3. High resolution integral holography using Fourier ptychographic approach.

    Science.gov (United States)

    Li, Zhaohui; Zhang, Jianqi; Wang, Xiaorui; Liu, Delian

    2014-12-29

    An innovative approach is proposed for calculating high resolution computer generated integral holograms by using the Fourier Ptychographic (FP) algorithm. The approach initializes a high resolution complex hologram with a random guess, and then stitches together low resolution multi-view images, synthesized from the elemental images captured by integral imaging (II), to recover the high resolution hologram through an iterative retrieval with FP constrains. This paper begins with an analysis of the principle of hologram synthesis from multi-projections, followed by an accurate determination of the constrains required in the Fourier ptychographic integral-holography (FPIH). Next, the procedure of the approach is described in detail. Finally, optical reconstructions are performed and the results are demonstrated. Theoretical analysis and experiments show that our proposed approach can reconstruct 3D scenes with high resolution.

  4. High-resolution MRI in detecting subareolar breast abscess.

    Science.gov (United States)

    Fu, Peifen; Kurihara, Yasuyuki; Kanemaki, Yoshihide; Okamoto, Kyoko; Nakajima, Yasuo; Fukuda, Mamoru; Maeda, Ichiro

    2007-06-01

    Because subareolar breast abscess has a high recurrence rate, a more effective imaging technique is needed to comprehensively visualize the lesions and guide surgery. We performed a high-resolution MRI technique using a microscopy coil to reveal the characteristics and extent of subareolar breast abscess. High-resolution MRI has potential diagnostic value in subareolar breast abscess. This technique can be used to guide surgery with the aim of reducing the recurrence rate.

  5. High-resolution esophageal pressure topography for esophageal motility disorders

    OpenAIRE

    Hashem Fakhre Yaseri; Gholamreza Hamsi; Tayeb Ramim

    2016-01-01

    Background: High-resolution manometer (HRM) of the esophagus has become the main diagnostic test in the evaluation of esophageal motility disorders. The development of high-resolution manometry catheters and software displays of manometry recordings in color-coded pressure plots have changed the diagnostic assessment of esophageal disease. The first step of the Chicago classification described abnormal esophagogastric junction deglutitive relaxation. The latest classification system, proposed...

  6. Volumetric expiratory high-resolution CT of the lung

    International Nuclear Information System (INIS)

    Nishino, Mizuki; Hatabu, Hiroto

    2004-01-01

    We developed a volumetric expiratory high-resolution CT (HRCT) protocol that provides combined inspiratory and expiratory volumetric imaging of the lung without increasing radiation exposure, and conducted a preliminary feasibility assessment of this protocol to evaluate diffuse lung disease with small airway abnormalities. The volumetric expiratory high-resolution CT increased the detectability of the conducting airway to the areas of air trapping (P<0.0001), and added significant information about extent and distribution of air trapping (P<0.0001)

  7. Developing Visual Editors for High-Resolution Haptic Patterns

    DEFF Research Database (Denmark)

    Cuartielles, David; Göransson, Andreas; Olsson, Tony

    2012-01-01

    In this article we give an overview of our iterative work in developing visual editors for creating high resolution haptic patterns to be used in wearable, haptic feedback devices. During the past four years we have found the need to address the question of how to represent, construct and edit high...... resolution haptic patterns so that they translate naturally to the user’s haptic experience. To solve this question we have developed and tested several visual editors...

  8. Application of gamma spectrometry technique in combination with weighing for material balance taking in the production of highly enriched U-A1 fuel

    International Nuclear Information System (INIS)

    Serin, P.A.

    1975-07-01

    The purpose of this project is to obtain the data on material balance for a batch of highly enriched U-Al alloys (used in the NRX and NRU reactors) during production of fuel, using gamma spectrometry (mainly the 186 KeV photopeak) and weighing, and to determine operational data of the Agency's single channel stabilized spectrometer (SAM-1) for measurement of the product typical for the production of highly enriched U-Al fuel (U-Al billets, fuel elements, scrap). The data collected indicates that gamma spectrometry using the single channel stabilized spectrometer is a valid non-destructive method of determining quantitatively U-235 content of U-Al alloy in the form of cast billets or extruded fuel elements providing that adequate standards are available. An accuracy of better than + 1% relative can be obtained using a simple jig to provide reproducible counting geometry. Count rates should be kept well below the saturation level of the detector and counter, preferably by a lead collimator in front of the detector. This non-destructive method is not easily applicable to scrap because of the inability to maintain constant geometry and to prepare standards closely similar in size and shape to the samples

  9. EMODnet High Resolution Seabed Mapping - further developing a high resolution digital bathymetry for European seas

    Science.gov (United States)

    Schaap, D.; Schmitt, T.

    2017-12-01

    Access to marine data is a key issue for the EU Marine Strategy Framework Directive and the EU Marine Knowledge 2020 agenda and includes the European Marine Observation and Data Network (EMODnet) initiative. EMODnet aims at assembling European marine data, data products and metadata from diverse sources in a uniform way. The EMODnet Bathymetry project has developed Digital Terrain Models (DTM) for the European seas. These have been produced from survey and aggregated data sets that are indexed with metadata by adopting the SeaDataNet Catalogue services. SeaDataNet is a network of major oceanographic data centres around the European seas that manage, operate and further develop a pan-European infrastructure for marine and ocean data management. The latest EMODnet Bathymetry DTM release has a grid resolution of 1/8 arcminute and covers all European sea regions. Use has been made of circa 7800 gathered survey datasets and composite DTMs. Catalogues and the EMODnet DTM are published at the dedicated EMODnet Bathymetry portal including a versatile DTM viewing and downloading service. End December 2016 the Bathymetry project has been succeeded by EMODnet High Resolution Seabed Mapping (HRSM). This continues gathering of bathymetric in-situ data sets with extra efforts for near coastal waters and coastal zones. In addition Satellite Derived Bathymetry data are included to fill gaps in coverage of the coastal zones. The extra data and composite DTMs will increase the coverage of the European seas and its coastlines, and provide input for producing an EMODnet DTM with a common resolution of 1/16 arc minutes. The Bathymetry Viewing and Download service will be upgraded to provide a multi-resolution map and including 3D viewing. The higher resolution DTMs will also be used to determine best-estimates of the European coastline for a range of tidal levels (HAT, MHW, MSL, Chart Datum, LAT), thereby making use of a tidal model for Europe. Extra challenges will be `moving to the

  10. A method for generating high resolution satellite image time series

    Science.gov (United States)

    Guo, Tao

    2014-10-01

    There is an increasing demand for satellite remote sensing data with both high spatial and temporal resolution in many applications. But it still is a challenge to simultaneously improve spatial resolution and temporal frequency due to the technical limits of current satellite observation systems. To this end, much R&D efforts have been ongoing for years and lead to some successes roughly in two aspects, one includes super resolution, pan-sharpen etc. methods which can effectively enhance the spatial resolution and generate good visual effects, but hardly preserve spectral signatures and result in inadequate analytical value, on the other hand, time interpolation is a straight forward method to increase temporal frequency, however it increase little informative contents in fact. In this paper we presented a novel method to simulate high resolution time series data by combing low resolution time series data and a very small number of high resolution data only. Our method starts with a pair of high and low resolution data set, and then a spatial registration is done by introducing LDA model to map high and low resolution pixels correspondingly. Afterwards, temporal change information is captured through a comparison of low resolution time series data, and then projected onto the high resolution data plane and assigned to each high resolution pixel according to the predefined temporal change patterns of each type of ground objects. Finally the simulated high resolution data is generated. A preliminary experiment shows that our method can simulate a high resolution data with a reasonable accuracy. The contribution of our method is to enable timely monitoring of temporal changes through analysis of time sequence of low resolution images only, and usage of costly high resolution data can be reduces as much as possible, and it presents a highly effective way to build up an economically operational monitoring solution for agriculture, forest, land use investigation

  11. Selection and optimization of spectrometric amplifiers for gamma spectrometry: part II - linearity, live time correction factors and software

    International Nuclear Information System (INIS)

    Moraes, Marco Antonio Proenca Vieira de; Pugliesi, Reinaldo

    1996-01-01

    The objective of the present work was to establish simple criteria to choose the best combination of electronic modules to achieve an adequate high resolution gamma spectrometer. Linearity, live time correction factors and softwares of a gamma spectrometric system composed by a Hp Ge detector have been studied by using several kinds of spectrometric amplifiers: Canberra 2021, Canberra 2025, Ortec 673 and Tennelec 244 and the MCA cards Ortec and Nucleus. The results showed low values of integral non-linearity for all spectrometric amplifiers connected to the Ortec and Nucleus boards. The MCA card should be able to correct amplifier dead time for 17 kcps count rates. (author)

  12. High resolution manometry findings in patients with esophageal epiphrenic diverticula.

    Science.gov (United States)

    Vicentine, Fernando P P; Herbella, Fernando A M; Silva, Luciana C; Patti, Marco G

    2011-12-01

    The pathophysiology of esophageal epiphrenic diverticula is still uncertain even though a concomitant motility disorder is found in the majority of patients in different series. High resolution manometry may allow detection of motor abnormalities in a higher number of patients with esophageal epiphrenic diverticula compared with conventional manometry. This study aims to evaluate the high resolution manometry findings in patients with esophageal epiphrenic diverticula. Nine individuals (mean age 63 ± 10 years, 4 females) with esophageal epiphrenic diverticula underwent high resolution manometry. A single diverticulum was observed in eight patients and multiple diverticula in one. Visual analysis of conventional tracings and color pressure plots for identification of segmental abnormalities was performed by two researchers experienced in high resolution manometry. Upper esophageal sphincter was normal in all patients. Esophageal body was abnormal in eight patients; lower esophageal sphincter was abnormal in seven patients. Named esophageal motility disorders were found in seven patients: achalasia in six, diffuse esophageal spasm in one. In one patient, a segmental hypercontractile zone was noticed with pressure of 196 mm Hg. High resolution manometry demonstrated motor abnormalities in all patients with esophageal epiphrenic diverticula.

  13. Compact and high-resolution optical orbital angular momentum sorter

    Directory of Open Access Journals (Sweden)

    Chenhao Wan

    2017-03-01

    Full Text Available A compact and high-resolution optical orbital angular momentum (OAM sorter is proposed and demonstrated. The sorter comprises a quadratic fan-out mapper and a dual-phase corrector positioned in the pupil plane and the Fourier plane, respectively. The optical system is greatly simplified compared to previous demonstrations of OAM sorting, and the performance in resolution and efficiency is maintained. A folded configuration is set up using a single reflective spatial light modulator (SLM to demonstrate the validity of the scheme. The two phase elements are implemented on the left and right halves of the SLM and connected by a right-angle prism. Experimental results demonstrate the high resolution of the compact OAM sorter, and the current limit in efficiency can be overcome by replacing with transmissive SLMs and removing the beam splitters. This novel scheme paves the way for the miniaturization and integration of high-resolution OAM sorters.

  14. High-resolution SPECT for small-animal imaging

    International Nuclear Information System (INIS)

    Qi Yujin

    2006-01-01

    This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency. (authors)

  15. High-resolution spectroscopy of gases for industrial applications

    DEFF Research Database (Denmark)

    Fateev, Alexander; Clausen, Sønnik

    High-resolution spectroscopy of gases is a powerful technique which has various fundamental and practical applications: in situ simultaneous measurements of gas temperature and gas composition, radiative transfer modeling, validation of existing and developing of new databases and etc. Existing...... databases (e.g. HITRAN, HITEMP or CDSD) can normally be used for absorption spectra calculations at limited temperature/pressure ranges. Therefore experimental measurements of absorption/transmission spectra gases (e.g. CO2, H2O or SO2) at high-resolution and elevated temperatures are essential both...... for analysis of complex experimental data and further development of the databases. High-temperature gas cell facilities available at DTU Chemical Engineering are presented and described. The gas cells and high-resolution spectrometers allow us to perform high-quality reference measurements of gases relevant...

  16. High resolution analysis of temporal variation of airborne radionuclides

    International Nuclear Information System (INIS)

    Komura, K.; Yamaguchi, Y.; Manikandan, M.; Murata, Y.; Iida, T.; Moriizumi, J.

    2004-01-01

    One of the application of ultra low-background gamma spectrometry, we tried to measure temporal variation of airborne radionuclides at intervals of 1 to few hours in extreme case. Airborne radionuclides were collected on a filter paper made of quartz fiber at the Low Level Radioactivity Laboratory (LLRL), Kanazawa Univ. in Tatsunokuchi (since Nov. 2002), Hegra Island located 50 km from Noto peninsula (since Apr. 2003) to investigate influence of Asian continent and Shishiku plateau at 640 m above sea to know vertical difference (since Sep., 2003). Pb-210, Pb-212 and Be-7 were measured nondestructively by ultra low background Ge detectors in Ogoya Underground Laboratory (270 meter water Concentration of Rn-222 was monitored 1 hour intervals and wind direction and speed were recorded 10 min or 2 min intervals (Hegra Is.) as support data in data analyses. In the regular monitoring, sampling was made at 1-2 day (LLRL and Shishiku) or 1 week intervals (Hegra) to know daily and seasonal variations and similarity or difference between sampling locations. When drastic meteorological change, such as passage of front or typhoon, occurrence of inversion layer and snow fall etc., short sampling at 1-2 hours of intervals was conducted to find the corrlation with meteorological factors at single point or 2 points simultaneously. As a results, it was found that concentrations of Pb-210, Po-210, Pb-212 and Be-7 were found to vary very quickly in a short time (see Figure below) due mainly to horizontal or vertical mixing of air-masses. (authors)

  17. 1024 matrix image reconstruction: usefulness in high resolution chest CT

    International Nuclear Information System (INIS)

    Jeong, Sun Young; Chung, Myung Jin; Chong, Se Min; Sung, Yon Mi; Lee, Kyung Soo

    2006-01-01

    We tried to evaluate whether high resolution chest CT with a 1,024 matrix has a significant advantage in image quality compared to a 512 matrix. Each set of 512 and 1024 matrix high resolution chest CT scans with both 0.625 mm and 1.25 mm slice thickness were obtained from 26 patients. Seventy locations that contained twenty-four low density lesions without sharp boundary such as emphysema, and forty-six sharp linear densities such as linear fibrosis were selected; these were randomly displayed on a five mega pixel LCD monitor. All the images were masked for information concerning the matrix size and slice thickness. Two chest radiologists scored the image quality of each ar rowed lesion as follows: (1) undistinguishable, (2) poorly distinguishable, (3) fairly distinguishable, (4) well visible and (5) excellently visible. The scores were compared from the aspects of matrix size, slice thickness and the different observers by using ANOVA tests. The average and standard deviation of image quality were 3.09 (± .92) for the 0.625 mm x 512 matrix, 3.16 (± .84) for the 0.625 mm x 1024 matrix, 2.49 (± 1.02) for the 1.25 mm x 512 matrix, and 2.35 (± 1.02) for the 1.25 mm x 1024 matrix, respectively. The image quality on both matrices of the high resolution chest CT scans with a 0.625 mm slice thickness was significantly better than that on the 1.25 mm slice thickness (ρ < 0.001). However, the image quality on the 1024 matrix high resolution chest CT scans was not significantly different from that on the 512 matrix high resolution chest CT scans (ρ = 0.678). The interobserver variation between the two observers was not significant (ρ = 0.691). We think that 1024 matrix image reconstruction for high resolution chest CT may not be clinical useful

  18. Reproducible high-resolution multispectral image acquisition in dermatology

    Science.gov (United States)

    Duliu, Alexandru; Gardiazabal, José; Lasser, Tobias; Navab, Nassir

    2015-07-01

    Multispectral image acquisitions are increasingly popular in dermatology, due to their improved spectral resolution which enables better tissue discrimination. Most applications however focus on restricted regions of interest, imaging only small lesions. In this work we present and discuss an imaging framework for high-resolution multispectral imaging on large regions of interest.

  19. Dye laser light for high-resolution classical photography

    International Nuclear Information System (INIS)

    Geissler, K.K.

    1982-01-01

    The test run with the bubble chamber HOLEBC in October 1981 offered the opportunity of checking the usefulness of de-speckled dye laser light for illumination purposes in high-resolution classical dark field photography of small bubble chambers. (orig./HSI)

  20. High-resolution seismic imaging of the Sohagpur Gondwana basin ...

    Indian Academy of Sciences (India)

    The quality of the high-resolution seismic data depends mainly on the data ..... metric rift geometry. Based on the .... Biswas S K 2003 Regional tectonic framework of the .... Sheth H C, Ray J S, Ray R, Vanderkluysen L, Mahoney J. J, Kumar A ...

  1. Pulmonary Gaucher's disease: high-resolution computed tomographic features

    International Nuclear Information System (INIS)

    Tunaci, A.; Berkmen, Y.M.; Goekmen, E.

    1995-01-01

    CT findings in pulmonary Gaucher's disease have not been previously reported. Chest radiograph of a patient with pulmonary involvement in type I Gaucher's disease proven by biopsy showed linear and reticulo-nodular opacities. High-resolution CT demonstrated thickening of the interlobular septa and between four and six small nodules within secondary lobules, probably each corresponding to an acinus. (orig.)

  2. High resolution techniques using scanning proton microprobe (SPM)

    International Nuclear Information System (INIS)

    Cholewa, M.; Saint, A.; Prawer, S.; Laird, J.S.; Legge, G.J.F.; Bardos, R.A.; Moorhead, G.F.; Taylor, G.N.; Stuart, S.A.; Howard, J.

    1994-01-01

    The very high resolution (down to 50 nm) achieved with low beam currents (fA) in a scanning ion microprobe have lead to many nondestructive techniques of microanalysis. This paper discusses recent developments and applications in the use of 3-D STIM (scanning transmission ion microscopy) Tomography, channeling STIM and IBIC (ion beam induced charge). (orig.)

  3. Structure Identification in High-Resolution Transmission Electron Microscopic Images

    DEFF Research Database (Denmark)

    Vestergaard, Jacob Schack; Kling, Jens; Dahl, Anders Bjorholm

    2014-01-01

    A connection between microscopic structure and macroscopic properties is expected for almost all material systems. High-resolution transmission electron microscopy is a technique offering insight into the atomic structure, but the analysis of large image series can be time consuming. The present ...

  4. Duchenne muscular dystrophy: High-resolution melting curve ...

    African Journals Online (AJOL)

    Duchenne muscular dystrophy: High-resolution melting curve analysis as an affordable diagnostic mutation scanning tool in a South African cohort. ... Genetic screening for D/BMD in South Africa currently includes multiple ligase-dependent probe amplification (MLPA) for exonic deletions and duplications and linkage ...

  5. Role of land state in a high resolution mesoscale model

    Indian Academy of Sciences (India)

    ... Proceedings – Mathematical Sciences · Resonance – Journal of Science ... Land surface characteristics; high resolution mesoscale model; Uttarakhand ... to predict realistic location, timing, amount,intensity and distribution of rainfall ... region embedded within two low pressure centers over Arabian Seaand Bay of Bengal.

  6. A high resolution powder diffractometer using focusing optics

    Indian Academy of Sciences (India)

    E-mail: siruguri@csr.ernet.in. Abstract. In this paper, we describe the design, construction and performance of a new high resolution neutron powder diffractometer that has been installed at the Dhruva reactor, Trombay, India. The instrument employs novel design concepts like the use of bent, perfect crystal monochromator ...

  7. Application of high resolution SNP arrays in patients with congenital ...

    Indian Academy of Sciences (India)

    clinical experience in implementing whole-genome high-resolution SNP arrays to investigate 33 patients with syndromic and .... Online Mendelian Inheritance in Man database (OMIM, ..... of damaged mitochondria through either autophagy or mito- ..... malformations: associations with maternal and infant character- istics in a ...

  8. Workshop on high-resolution, large-acceptance spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Zeidman, B. (ed.)

    1981-01-01

    The purpose of the Workshop on High-Resolution, Large-Acceptance Spectrometers was to provide a means for exchange of information among those actively engaged in the design and construction of these new spectrometers. Thirty-seven papers were prepared for the data base.

  9. Yeast expression proteomics by high-resolution mass spectrometry

    DEFF Research Database (Denmark)

    Walther, Tobias C; Olsen, Jesper Velgaard; Mann, Matthias

    2010-01-01

    -translational controls contribute majorly to regulation of protein abundance, for example in heat shock stress response. The development of new sample preparation methods, high-resolution mass spectrometry and novel bioinfomatic tools close this gap and allow the global quantitation of the yeast proteome under different...

  10. High resolution satellite imagery : from spies to pipeline management

    Energy Technology Data Exchange (ETDEWEB)

    Adam, S. [Canadian Geomatic Solutions Ltd., Calgary, AB (Canada); Farrell, M. [TransCanada Transmission, Calgary, AB (Canada)

    2000-07-01

    The launch of Space Imaging's IKONOS satellite in September 1999 has opened the door for corridor applications. The technology has been successfully implemented by TransCanada PipeLines in mapping over 1500 km of their mainline. IKONOS is the world's first commercial high resolution satellite which collects data at 1-meter black/white and 4-meter multi-spectral. Its use is regulated by the U.S. government. It is the best source of high resolution satellite image data. Other sources include the Indian Space Agency's IRS-1 C/D satellite and the Russian SPIN-2 which provides less reliable coverage. In addition, two more high resolution satellites may be launched this year to provide imagery every day of the year. IKONOS scenes as narrow as 5 km can be purchased. TransCanada conducted a pilot study to determine if high resolution satellite imagery is as effective as ortho-photos for identifying population structures within a buffer of TransCanada's east line right-of-way. The study examined three unique segments where residential, commercial, industrial and public features were compared. It was determined that IKONOS imagery is as good as digital ortho-photos for updating structures from low to very high density areas. The satellite imagery was also logistically easier than ortho-photos to acquire. This will be even more evident when the IKONOS image archives begins to grow. 4 tabs., 3 figs.

  11. Novel techniques in VUV high-resolution spectroscopy

    NARCIS (Netherlands)

    Ubachs, W.M.G.; Salumbides, E.J.; Eikema, K.S.E.; de Oliveira, N.; Nahon, L.

    2014-01-01

    Novel VUV sources and techniques for VUV spectroscopy are reviewed. Laser-based VUV sources have been developed via non-linear upconversion of laser pulses in the nanosecond (ns), the picosecond (ps), and femtosecond (fs) domain, and are applied in high-resolution gas phase spectroscopic studies.

  12. High resolution X-ray diffraction studies on unirradiated

    Indian Academy of Sciences (India)

    High-resolution X-ray diffraction technique, employing a three-crystal monochromator–collimator combination is used to study the irradiation induced defects in flux grown Sr-hexaferrite crystals irradiated with 50 MeV Li3+ ion beams at room temperature with a fluence value of 1 × 1014 ions/cm2. The diffraction curves of the ...

  13. High resolution STEM of quantum dots and quantum wires

    DEFF Research Database (Denmark)

    Kadkhodazadeh, Shima

    2013-01-01

    This article reviews the application of high resolution scanning transmission electron microscopy (STEM) to semiconductor quantum dots (QDs) and quantum wires (QWRs). Different imaging and analytical techniques in STEM are introduced and key examples of their application to QDs and QWRs...

  14. Pattern of interstitial lung disease detected by high resolution ...

    African Journals Online (AJOL)

    Background: Diffuse lung diseases constitute a major cause of morbidity and mortality worldwide. High Resolution Computed Tomography (HRCT) is the recommended imaging technique in the diagnosis, assessment and followup of these diseases. Objectives: To describe the pattern of HRCT findings in patients with ...

  15. A multi-channel high-resolution time recorder system

    International Nuclear Information System (INIS)

    Zhang Lingyun; Yang Xiaojun; Song Kezhu; Wang Yanfang

    2004-01-01

    This paper introduces a multi-channel and high-speed time recorder system, which was originally designed to work in the experiments of quantum cryptography research. The novelty of the system is that all the hardware logic is performed by only one FPGA. The system can achieve several desirable features, such as simplicity, high resolution and high processing speed. (authors)

  16. Remote parallel rendering for high-resolution tiled display walls

    KAUST Repository

    Nachbaur, Daniel

    2014-11-01

    © 2014 IEEE. We present a complete, robust and simple to use hardware and software stack delivering remote parallel rendering of complex geometrical and volumetric models to high resolution tiled display walls in a production environment. We describe the setup and configuration, present preliminary benchmarks showing interactive framerates, and describe our contributions for a seamless integration of all the software components.

  17. Remote parallel rendering for high-resolution tiled display walls

    KAUST Repository

    Nachbaur, Daniel; Dumusc, Raphael; Bilgili, Ahmet; Hernando, Juan; Eilemann, Stefan

    2014-01-01

    © 2014 IEEE. We present a complete, robust and simple to use hardware and software stack delivering remote parallel rendering of complex geometrical and volumetric models to high resolution tiled display walls in a production environment. We describe the setup and configuration, present preliminary benchmarks showing interactive framerates, and describe our contributions for a seamless integration of all the software components.

  18. Human enamel structure studied by high resolution electron microscopy

    International Nuclear Information System (INIS)

    Wen, S.L.

    1989-01-01

    Human enamel structural features are characterized by high resolution electron microscopy. The human enamel consists of polycrystals with a structure similar to Ca10(PO4)6(OH)2. This article describes the structural features of human enamel crystal at atomic and nanometer level. Besides the structural description, a great number of high resolution images are included. Research into the carious process in human enamel is very important for human beings. This article firstly describes the initiation of caries in enamel crystal at atomic and unit-cell level and secondly describes the further steps of caries with structural and chemical demineralization. The demineralization in fact, is the origin of caries in human enamel. The remineralization of carious areas in human enamel has drawn more and more attention as its potential application is realized. This process has been revealed by high resolution electron microscopy in detail in this article. On the other hand, the radiation effects on the structure of human enamel are also characterized by high resolution electron microscopy. In order to reveal this phenomenon clearly, a great number of electron micrographs have been shown, and a physical mechanism is proposed. 26 references

  19. High resolution and high speed positron emission tomography data acquisition

    International Nuclear Information System (INIS)

    Burgiss, S.G.; Byars, L.G.; Jones, W.F.; Casey, M.E.

    1986-01-01

    High resolution positron emission tomography (PET) requires many detectors. Thus, data collection systems for PET must have high data rates, wide data paths, and large memories to histogram the events. This design uses the VMEbus to cost effectively provide these features. It provides for several modes of operation including real time sorting, list mode data storage, and replay of stored list mode data

  20. High resolution wind turbine wake measurements with a scanning lidar

    DEFF Research Database (Denmark)

    Herges, T. G.; Maniaci, D. C.; Naughton, B. T.

    2017-01-01

    High-resolution lidar wake measurements are part of an ongoing field campaign being conducted at the Scaled Wind Farm Technology facility by Sandia National Laboratories and the National Renewable Energy Laboratory using a customized scanning lidar from the Technical University of Denmark. One...

  1. High resolution mid-infrared spectroscopy based on frequency upconversion

    DEFF Research Database (Denmark)

    Dam, Jeppe Seidelin; Hu, Qi; Tidemand-Lichtenberg, Peter

    2013-01-01

    signals can be analyzed. The obtainable frequency resolution is usually in the nm range where sub nm resolution is preferred in many applications, like gas spectroscopy. In this work we demonstrate how to obtain sub nm resolution when using upconversion. In the presented realization one object point...... high resolution spectral performance by observing emission from hot water vapor in a butane gas burner....

  2. Systematic high-resolution assessment of global hydropower potential

    NARCIS (Netherlands)

    Hoes, Olivier A C; Meijer, Lourens J J; Van Der Ent, Ruud J.|info:eu-repo/dai/nl/364164794; Van De Giesen, Nick C.

    2017-01-01

    Population growth, increasing energy demand and the depletion of fossil fuel reserves necessitate a search for sustainable alternatives for electricity generation. Hydropower could replace a large part of the contribution of gas and oil to the present energy mix. However, previous high-resolution

  3. High-Resolution Geologic Mapping of Martian Terraced Fan Deposits

    Science.gov (United States)

    Wolak, J. M.; Patterson, A. B.; Smith, S. D.; Robbins, N. N.

    2018-06-01

    This abstract documents our initial progress (year 1) mapping terraced fan features on Mars. Our objective is to investigate the role of fluids during fan formation and produce the first high-resolution geologic map (1:18k) of a terraced fan.

  4. Natural activity in Hudson River estuary samples and their influence on the detection limits for gamma emitting radionuclides using NaI gamma spectrometry

    International Nuclear Information System (INIS)

    Wrenn, M.E.; Jinks, S.M.; Hairr, L.M.; Paschoa, A.S.; Lentsch, J.W.

    1972-01-01

    Sources of natural radioactivity in Hudson River Estuary are described. The technique of analysis for gamma spectrometry of environmental samples is presented and its pros and cons discussed. The distribution of natural radioactivity in water, biota and sediment was reported as well as the role played by the vertical distribution of cesium-137 in sediments as an indicator of the rate of sedimentation. The effect of the presence of natural radionuclides on the detection limits of man-made nuclides in the Hudson River environment is thoroughly examined. The results obtained with a 4-in. sodium iodide well crystal housed in a low background mercury shielding compare favorably with a more sophisticated Ge(Li) system which uses anticoincidence, as far as the analysis of environmental samples is concerned. (U.S.)

  5. High energy resolution and high count rate gamma spectrometry measurement of primary coolant of generation 4 sodium-cooled fast reactor

    International Nuclear Information System (INIS)

    Coulon, R.

    2010-01-01

    Sodium-cooled Fast Reactors are under development for the fourth generation of nuclear reactor. Breeders reactors could gives solutions for the need of energy and the preservation of uranium resources. An other purpose is the radioactive wastes production reduction by transmutation and the control of non-proliferation using a closed-cycle. These thesis shows safety and profit advantages that could be obtained by a new generation of gamma spectrometry system for SFR. Now, the high count rate abilities, allow us to study new methods of accurate power measurement and fast clad failure detection. Simulations have been done and an experimental test has been performed at the French Phenix SFR of the CEA Marcoule showing promising results for these new measurements. (author) [fr

  6. Burnup determination of power reactor fuel elements by gamma spectrometry; Determination par spectrometrie {gamma} du taux d'irradiation des elements combustibles des reacteurs de puissance

    Energy Technology Data Exchange (ETDEWEB)

    Robin, M; Jastrzeb, M; Boisliveau, S; Boyer, R; Vidal, R [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    This report describes a method for determining by {gamma} spectrometry the burn up and the specific power of fuel elements irradiated in power reactors. The energy spectrum of {gamma} rays emitted by fission products is measured by means of a simple equipment using a sodium iodide detector and a multichannel analyzer. In order to extract from the spectrum a quantity proportional to the burn up, it is necessary to: - isolate an activity specific of one emitter,- give the same importance to fissions in uranium and plutonium - take into account the radioactive decay during and after irradiation. One hundred fuel elements were studied and burn up values obtained by {gamma} spectrometry are compared to results given by chemical analyses. Preliminary measurements show that the accuracy of the results is greatly increased by the use of a germanium detector, due to its good resolution. (authors) [French] Ce rapport expose une methode de determination par spectrometrie {gamma} du taux d'irradiation et de la puissance specifique des elements combustibles irradies dans les reacteurs de puissance. Une installation simple utilisant un detecteur d'iodure de sodium et un selecteur multicanaux mesure le spectre en energie du rayonnement {gamma} emis par les produits de fission. Afin d'extraire du spectre une quantite proportionnelle au taux de combustion, il faut: - isoler une activite specifique a un emetteur, - donner la meme importance aux fissions survenues dans l'uranium et le plutonium, - prendre en compte la decroissance radioactive pendant et apres l'irradiation. Les mesures ont porte sur une centaine d'elements combustibles et les taux de combustion obtenus par spectrometrie {gamma} sont compares aux resultats des analyses chimiques. Des mesures preliminaires montrent que l'utilisation d'un detecteur de germanium augmente considerablement la precision des resultats, en raison de son excellente resolution. (auteurs)

  7. In situ gamma spectrometry aspects of an European intercomparison of national networks used to provide early warning of a nuclear accident

    International Nuclear Information System (INIS)

    Gurriaran, R.; Lemercier, M.; Bouisset, P.; Cagnat, X.; Saez-Vergara, J. C.; Tyler, A. N.

    2006-01-01

    In 2002, the EURADOS Working Group on Environmental Monitoring organised the second European intercomparison exercise of national network systems used to provide early warning in case of a nuclear accident. The aim of the exercise is to ensure consistent and comparable results reported by different countries during a nuclear accident, hence avoiding that the dose rate measurements reported present steps at national borders due to different calibrations or different measurement quantities being used. The exercise studied the response of the detectors to different situations: Free field site, a flat area covered with grass. The detectors where in presence of environmental radiation and point sources. Radioactive plume simulator. An incident was simulated by gradually increasing the ambient dose rate by values up to 50% of the normal value. Cosmic radiation site. A platform installed in the middle of a lake permitted to study the response of detectors to cosmic rays in the absence of other components. Ultra low background laboratory (UDO). Situated at 925 m in a salt mine this unique facility has a very low ambient dose (<1 nSv/h) and permitted the study of the response of detectors to collimated beams, in the absence of other components. The exercise was focused on the systems that continuously monitor the ambient dose rate but a novelty in the 2002 intercomparison was the participation of in situ gamma spectrometry teams. This presentation will focus on the in situ gamma spectrometry aspects: The interest of having the energy spectra information in order to discriminate the different contributors to the ambient dose, and the work that has been done in order to ensure an agreement between the dosimetry aspects and the spectrometry results

  8. Low-energy X-ray and gamma spectrometry using silicon photodiodes; Espectrometria de raios X e gama de baixa energia utilizando fotodiodos de silicio

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Iran Jose Oliveira da

    2000-08-01

    The use of semiconductor detectors for radiation detection has increased in recent years due to advantages they present in comparison to other types of detectors. As the working principle of commercially available photodiodes is similar to the semiconductor detector, this study was carried out to evaluate the use of Si photodiodes for low energy x-ray and gamma spectrometry. The photodiodes investigated were SFH-205, SFH-206, BPW-34 and XRA-50 which have the following characteristics: active area of 0,07 cm{sup 2} and 0,25 cm{sup 2}, thickness of the depletion ranging from 100 to 200 {mu}m and junction capacitance of 72 pF. The photodiode was polarized with a reverse bias and connected to a charge sensitive pre-amplifier, followed by a amplifier and multichannel pulse analyzer. Standard radiation source used in this experiment were {sup 241} Am, {sup 109} Cd, {sup 57} Co and {sup 133} Ba. The X-ray fluorescence of lead and silver were also measured through K- and L-lines. All the measurements were made with the photodiodes at room temperature.The results show that the responses of the photodiodes very linear by the x-ray energy and that the energy resolution in FWHM varied between 1.9 keV and 4.4 keV for peaks corresponding to 11.9 keV to 59 keV. The BPW-34 showed the best energy resolution and the lower dark current. The full-energy peak efficiency was also determined and it was observed that the peak efficiency decreases rapidly above 50 keV. The resolution and efficiency are similar to the values obtained with other semiconductor detectors, evidencing that the photodiodes used in that study can be used as a good performance detector for low energy X-ray and gamma spectrometry. (author)

  9. High-resolution axial MR imaging of tibial stress injuries

    Directory of Open Access Journals (Sweden)

    Mammoto Takeo

    2012-05-01

    Full Text Available Abstract Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries.

  10. High-resolution axial MR imaging of tibial stress injuries

    Science.gov (United States)

    2012-01-01

    Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries. PMID:22574840

  11. High-resolution structure of the native histone octamer

    International Nuclear Information System (INIS)

    Wood, Christopher M.; Nicholson, James M.; Lambert, Stanley J.; Chantalat, Laurent; Reynolds, Colin D.; Baldwin, John P.

    2005-01-01

    The high-resolution (1.90 Å) model of the native histone octamer allows structural comparisons to be made with the nucleosome-core particle, along with an identification of a likely core-histone binding site. Crystals of native histone octamers (H2A–H2B)–(H4–H3)–(H3′–H4′)–(H2B′–H2A′) from chick erythrocytes in 2 M KCl, 1.35 M potassium phosphate pH 6.9 diffract X-rays to 1.90 Å resolution, yielding a structure with an R work value of 18.7% and an R free of 22.2%. The crystal space group is P6 5 , the asymmetric unit of which contains one complete octamer. This high-resolution model of the histone-core octamer allows further insight into intermolecular interactions, including water molecules, that dock the histone dimers to the tetramer in the nucleosome-core particle and have relevance to nucleosome remodelling. The three key areas analysed are the H2A′–H3–H4 molecular cluster (also H2A–H3′–H4′), the H4–H2B′ interaction (also H4′–H2B) and the H2A′–H4 β-sheet interaction (also H2A–H4′). The latter of these three regions is important to nucleosome remodelling by RNA polymerase II, as it is shown to be a likely core-histone binding site, and its disruption creates an instability in the nucleosome-core particle. A majority of the water molecules in the high-resolution octamer have positions that correlate to similar positions in the high-resolution nucleosome-core particle structure, suggesting that the high-resolution octamer model can be used for comparative studies with the high-resolution nucleosome-core particle

  12. High resolution color imagery for orthomaps and remote sensing

    Energy Technology Data Exchange (ETDEWEB)

    Fricker, Peter [Leica Geosystems GIS and Mapping, LLC (Switzerland); Gallo, M. Guillermo [Leica Geosystems GIS and Mapping, LLC (United States)

    2005-07-01

    The ADS40 Airborne Digital Pushbroom Sensor is currently the only commercial sensor capable of acquiring color and false color strip images in the low decimeter range at the same high resolution as the black and white stereo images. This high resolution of 12,000 pixels across the entire swath and 100% forward overlap in the image strips result in high quality DSM's, True Ortho's and at the same time allow unbiased remote sensing applications due to color strip images unchanged by pan-sharpening. The paper gives details on how the pushbroom sensor achieves these seemingly difficult technical challenges. It describes how a variety of mapping applications benefit from this sensor, a sensor which acts as a satellite pushbroom sensor within the airborne environment. (author)

  13. Ring artifact correction for high-resolution micro CT

    International Nuclear Information System (INIS)

    Kyriakou, Yiannis; Prell, Daniel; Kalender, Willi A

    2009-01-01

    In high-resolution micro CT using flat detectors (FD), imperfect or defect detector elements may cause concentric-ring artifacts due to their continuous over- or underestimation of attenuation values, which often disturb image quality. We here present a dedicated image-based ring artifact correction method for high-resolution micro CT, based on median filtering of the reconstructed image and working on a transformed version of the reconstructed images in polar coordinates. This post-processing method reduced ring artifacts in the reconstructed images and improved image quality for phantom and in in vivo scans. Noise and artifacts were reduced both in transversal and in multi-planar reformations along the longitudinal axis. (note)

  14. High resolution spectroscopy in solids by nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Bonagamba, T.J.

    1991-07-01

    The nuclear magnetic resonance (NMR) techniques for High Resolution Spectroscopy in Solids are described. Also the construction project of a partially home made spectrometer and its applications in the characterization of solid samples are shown in detail. The high resolution spectrometer used is implemented with the double resonance multiple pulses sequences and magic angle spinning (MAS) and can be used with solid and liquid samples. The maximum spinning frequency for the MAS experiment is in excess of 5 Khz, the double resonance sequences can be performed with any type of nucleus, in the variable temperature operating range with nitrogen gas: -120 0 C to +160 0 C, and is fully controlled by a Macintosh IIci microcomputer. (author)

  15. High resolution radar satellite imagery analysis for safeguards applications

    Energy Technology Data Exchange (ETDEWEB)

    Minet, Christian; Eineder, Michael [German Aerospace Center, Remote Sensing Technology Institute, Department of SAR Signal Processing, Wessling, (Germany); Rezniczek, Arnold [UBA GmbH, Herzogenrath, (Germany); Niemeyer, Irmgard [Forschungszentrum Juelich, Institue of Energy and Climate Research, IEK-6: Nuclear Waste Management and Reactor Safety, Juelich, (Germany)

    2011-12-15

    For monitoring nuclear sites, the use of Synthetic Aperture Radar (SAR) imagery shows essential promises. Unlike optical remote sensing instruments, radar sensors operate under almost all weather conditions and independently of the sunlight, i.e. time of the day. Such technical specifications are required both for continuous and for ad-hoc, timed surveillance tasks. With Cosmo-Skymed, TerraSARX and Radarsat-2, high-resolution SAR imagery with a spatial resolution up to 1m has recently become available. Our work therefore aims to investigate the potential of high-resolution TerraSAR data for nuclear monitoring. This paper focuses on exploiting amplitude of a single acquisition, assessing amplitude changes and phase differences between two acquisitions, and PS-InSAR processing of an image stack.

  16. High resolution reservoir geological modelling using outcrop information

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Changmin; Lin Kexiang; Liu Huaibo [Jianghan Petroleum Institute, Hubei (China)] [and others

    1997-08-01

    This is China`s first case study of high resolution reservoir geological modelling using outcrop information. The key of the modelling process is to build a prototype model and using the model as a geological knowledge bank. Outcrop information used in geological modelling including seven aspects: (1) Determining the reservoir framework pattern by sedimentary depositional system and facies analysis; (2) Horizontal correlation based on the lower and higher stand duration of the paleo-lake level; (3) Determining the model`s direction based on the paleocurrent statistics; (4) Estimating the sandbody communication by photomosaic and profiles; (6) Estimating reservoir properties distribution within sandbody by lithofacies analysis; and (7) Building the reservoir model in sandbody scale by architectural element analysis and 3-D sampling. A high resolution reservoir geological model of Youshashan oil field has been built by using this method.

  17. High resolution spectroscopy in the microwave and far infrared

    Science.gov (United States)

    Pickett, Herbert M.

    1990-01-01

    High resolution rotational spectroscopy has long been central to remote sensing techniques in atmospheric sciences and astronomy. As such, laboratory measurements must supply the required data to make direct interpretation of data for instruments which sense atmospheres using rotational spectra. Spectral measurements in the microwave and far infrared regions are also very powerful tools when combined with infrared measurements for characterizing the rotational structure of vibrational spectra. In the past decade new techniques were developed which have pushed high resolution spectroscopy into the wavelength region between 25 micrometers and 2 mm. Techniques to be described include: (1) harmonic generation of microwave sources, (2) infrared laser difference frequency generation, (3) laser sideband generation, and (4) ultrahigh resolution interferometers.

  18. High-resolution observation by double-biprism electron holography

    International Nuclear Information System (INIS)

    Harada, Ken; Tonomura, Akira; Matsuda, Tsuyoshi; Akashi, Tetsuya; Togawa, Yoshihiko

    2004-01-01

    High-resolution electron holography has been achieved by using a double-biprism interferometer implemented on a 1 MV field emission electron microscope. The interferometer was installed behind the first magnifying lens to narrow carrier fringes and thus enabled complete separation of sideband Fourier spectrum from center band in reconstruction process. Holograms of Au fine particles and single-crystalline thin films with the finest fringe spacing of 4.2 pm were recorded and reconstructed. The overall holography system including the reconstruction process performed well for holograms in which carrier fringes had a spacing of around 10 pm. High-resolution lattice images of the amplitude and phase were clearly reconstructed without mixing of the center band and sideband information. Additionally, entire holograms were recorded without Fresnel fringes normally generated by the filament electrode of the biprism, and the holograms were thus reconstructed without the artifacts caused by Fresnel fringes

  19. Automated data processing of high-resolution mass spectra

    DEFF Research Database (Denmark)

    Hansen, Michael Adsetts Edberg; Smedsgaard, Jørn

    of the massive amounts of data. We present an automated data processing method to quantitatively compare large numbers of spectra from the analysis of complex mixtures, exploiting the full quality of high-resolution mass spectra. By projecting all detected ions - within defined intervals on both the time...... infusion of crude extracts into the source taking advantage of the high sensitivity, high mass resolution and accuracy and the limited fragmentation. Unfortunately, there has not been a comparable development in the data processing techniques to fully exploit gain in high resolution and accuracy...... infusion analyses of crude extract to find the relationship between species from several species terverticillate Penicillium, and also that the ions responsible for the segregation can be identified. Furthermore the process can automate the process of detecting unique species and unique metabolites....

  20. Towards high-resolution positron emission tomography for small volumes

    International Nuclear Information System (INIS)

    McKee, B.T.A.

    1982-01-01

    Some arguments are made regarding the medical usefulness of high spatial resolution in positron imaging, even if limited to small imaged volumes. Then the intrinsic limitations to spatial resolution in positron imaging are discussed. The project to build a small-volume, high resolution animal research prototype (SHARP) positron imaging system is described. The components of the system, particularly the detectors, are presented and brief mention is made of data acquisition and image reconstruction methods. Finally, some preliminary imaging results are presented; a pair of isolated point sources and 18 F in the bones of a rabbit. Although the detector system is not fully completed, these first results indicate that the goals of high sensitivity and high resolution (4 mm) have been realized. (Auth.)

  1. High-resolution investigations of edge effects in neutron imaging

    International Nuclear Information System (INIS)

    Strobl, M.; Kardjilov, N.; Hilger, A.; Kuehne, G.; Frei, G.; Manke, I.

    2009-01-01

    Edge enhancement is the main effect measured by the so-called inline or propagation-based neutron phase contrast imaging method. The effect has originally been explained by diffraction, and high spatial coherence has been claimed to be a necessary precondition. However, edge enhancement has also been found in conventional imaging with high resolution. In such cases the effects can produce artefacts and hinder quantification. In this letter the edge effects at cylindrical shaped samples and long straight edges have been studied in detail. The enhancement can be explained by refraction and total reflection. Using high-resolution imaging, where spatial resolutions better than 50 μm could be achieved, refraction and total reflection peaks - similar to diffraction patterns - could be separated and distinguished.

  2. SRS station 16.3: high-resolution applications

    CERN Document Server

    Murphy, B M; Golshan, M; Moore, M; Reid, J; Kowalski, G

    2001-01-01

    Station 16.3 is a high-resolution X-ray diffraction beamline at Daresbury Laboratory Synchrotron Radiation Source. The data presented demonstrate the high-resolution available on the station utilising the recently commissioned four-reflection Si 1 1 1 monochromator and three-reflection Si 1 1 1 analyser. For comparison, a reciprocal space map of the two-bounce Si 1 1 1 monochromator and two-bounce analyser is also shown. Operation of the station is illustrated with examples for silicon, and for diamond. Lattice parameter variations were measured with accuracies in the part per million range and lattice tilts at the arc second level (DuMond, Phys. Rev. 52 (1937) 872).

  3. High-resolution nuclear magnetic resonance studies of proteins.

    Science.gov (United States)

    Jonas, Jiri

    2002-03-25

    The combination of advanced high-resolution nuclear magnetic resonance (NMR) techniques with high-pressure capability represents a powerful experimental tool in studies of protein folding. This review is organized as follows: after a general introduction of high-pressure, high-resolution NMR spectroscopy of proteins, the experimental part deals with instrumentation. The main section of the review is devoted to NMR studies of reversible pressure unfolding of proteins with special emphasis on pressure-assisted cold denaturation and the detection of folding intermediates. Recent studies investigating local perturbations in proteins and the experiments following the effects of point mutations on pressure stability of proteins are also discussed. Ribonuclease A, lysozyme, ubiquitin, apomyoglobin, alpha-lactalbumin and troponin C were the model proteins investigated.

  4. Turbine component casting core with high resolution region

    Science.gov (United States)

    Kamel, Ahmed; Merrill, Gary B.

    2014-08-26

    A hollow turbine engine component with complex internal features can include a first region and a second, high resolution region. The first region can be defined by a first ceramic core piece formed by any conventional process, such as by injection molding or transfer molding. The second region can be defined by a second ceramic core piece formed separately by a method effective to produce high resolution features, such as tomo lithographic molding. The first core piece and the second core piece can be joined by interlocking engagement that once subjected to an intermediate thermal heat treatment process thermally deform to form a three dimensional interlocking joint between the first and second core pieces by allowing thermal creep to irreversibly interlock the first and second core pieces together such that the joint becomes physically locked together providing joint stability through thermal processing.

  5. Precision crystal alignment for high-resolution electron microscope imaging

    International Nuclear Information System (INIS)

    Wood, G.J.; Beeching, M.J.

    1990-01-01

    One of the more difficult tasks involved in obtaining quality high-resolution electron micrographs is the precise alignment of a specimen into the required zone. The current accepted procedure, which involves changing to diffraction mode and searching for symmetric point diffraction pattern, is insensitive to small amounts of misalignment and at best qualitative. On-line analysis of the fourier space representation of the image, both for determining and correcting crystal tilt, is investigated. 8 refs., 42 figs

  6. A high resolution large dynamic range TDC circuit implementation

    International Nuclear Information System (INIS)

    Lei Wuhu; Liu Songqiu; Ye Weiguo; Han Hui; Li Pengyu

    2003-01-01

    Time measurement technology is usually used in nuclear experimentation. There are many methods of time measurement. The implementation method of Time to Digital Conversion (TDC) by means of electronic is a classical technology. The range and resolution of TDC is different according with different usage. A wide range and high resolution TDC circuit, including its theory and implementation way, is introduced in this paper. The test result is also given. (authors)

  7. A high resolution large dynamic range TDC circuit implementation

    International Nuclear Information System (INIS)

    Lei Wuhu; Liu Songqiu; Li Pengyu; Han Hui; Ye Yanlin

    2005-01-01

    Time measurement technology is usually used in nuclear experimentation. There are many methods of time measurement. The implementation method of Time to Digital Conversion (TDC) by means of electronics is a classical technology. The range and resolution of TDC is different according with different usage. A wide range and high resolution TDC circuit, including its theory and implementation way, is introduced in this paper. The test result is also given. (authors)

  8. Constraining Stochastic Parametrisation Schemes Using High-Resolution Model Simulations

    Science.gov (United States)

    Christensen, H. M.; Dawson, A.; Palmer, T.

    2017-12-01

    Stochastic parametrisations are used in weather and climate models as a physically motivated way to represent model error due to unresolved processes. Designing new stochastic schemes has been the target of much innovative research over the last decade. While a focus has been on developing physically motivated approaches, many successful stochastic parametrisation schemes are very simple, such as the European Centre for Medium-Range Weather Forecasts (ECMWF) multiplicative scheme `Stochastically Perturbed Parametrisation Tendencies' (SPPT). The SPPT scheme improves the skill of probabilistic weather and seasonal forecasts, and so is widely used. However, little work has focused on assessing the physical basis of the SPPT scheme. We address this matter by using high-resolution model simulations to explicitly measure the `error' in the parametrised tendency that SPPT seeks to represent. The high resolution simulations are first coarse-grained to the desired forecast model resolution before they are used to produce initial conditions and forcing data needed to drive the ECMWF Single Column Model (SCM). By comparing SCM forecast tendencies with the evolution of the high resolution model, we can measure the `error' in the forecast tendencies. In this way, we provide justification for the multiplicative nature of SPPT, and for the temporal and spatial scales of the stochastic perturbations. However, we also identify issues with the SPPT scheme. It is therefore hoped these measurements will improve both holistic and process based approaches to stochastic parametrisation. Figure caption: Instantaneous snapshot of the optimal SPPT stochastic perturbation, derived by comparing high-resolution simulations with a low resolution forecast model.

  9. High-Resolution Imaging of Colliding and Merging Galaxies

    Science.gov (United States)

    Whitmore, Brad

    1991-07-01

    We propose to obtain high-resolution images, using the WF/PC, of two colliding and merging galaxies (i.e., NGC 4038/4039 = "The Antennae" and NGC 7252 ="Atoms-for-Peace Galaxy". Our goal is to use HST to make critical observations of each object in order to gain a better understanding of the various phases of the merger process. Our primary objective is to determine whether globular clusters are formed during mergers\\?

  10. PROFIL-360 high resolution steam generator tube profilometry system

    International Nuclear Information System (INIS)

    Glass, S.W.

    1985-01-01

    A high-resolution profilometry system, PROFIL 360, has been developed to assess the condition of steam generator tubes and rapidly produce the data to evaluate the potential for developing in-service leaks. The probe has an electromechanical sensor in a rotating head. This technique has been demonstrated in the field, saving tubes that would have been plugged with the go-gauge criterion and indicating plugging other high-risk candidates that might otherwise not have been removed from service

  11. Profil-360 high resolution steam generator tube profilometry system

    International Nuclear Information System (INIS)

    Glass, S.W.

    1985-01-01

    A high-resolution profilometry system, PROFIL 360, has been developed to assess the condition of steam generator tubes and rapidly produce the data to evaluate the potential for developing in-service leaks. The probe has an electromechanical sensor in a rotating head. This technique has been demonstrated in the field, saving tubes that would have been plugged with the go-gauge criterion and indicating plugging other high-risk candidates that might otherwise not have been removed from service

  12. Tuberculous otitis media: findings on high-resolution CT

    International Nuclear Information System (INIS)

    Lungenschmid, D.; Buchberger, W.; Schoen, G.; Schoepf, R.; Mihatsch, T.; Birbamer, G.; Wicke, K.

    1993-01-01

    We describe two cases of tuberculous otitis media studied with high-resolution computed tomography (CT). Findings included extensive soft tissue densities with fluid levels in the tympanic cavity, the antrum, the mastoid and petrous air cells. Multifocal bony erosions and reactive bone sclerosis were seen as well. CT proved valuable for planning therapy by accurately displaying the involvement of the various structures of the middle and inner ear. However, the specific nature of the disease could only be presumed. (orig.)

  13. Environmental high resolution electron microscopy and applications to chemical science

    OpenAIRE

    Boyes, Edward; Gai, Pratibha

    2017-01-01

    An environmental cell high resolution electron microscope (EHREM) has been developed for in situ studies of dynamic chemical reactions on the atomic scale. It allows access to metastable intermediate phases of catalysts and to sequences of reversible microstructural and chemical development associated with the activation, deactivation and poisoning of a catalyst. Materials transported through air can be restored or recreated and samples damaged, e.g. by dehydration, by the usual vacuum enviro...

  14. Creating the High-Resolution Settlement Layer - lessons learned

    Science.gov (United States)

    Gros, A.

    2017-12-01

    Facebook publishes the High-resolution Settlement Layer (HRSL: https://ciesin.columbia.edu/data/hrsl/) in collaboration with Columbia University's CIESIN institute and the World Bank. So far, data for 13 countries have been published over the past nine months. HRSL data for Burkina Faso, Ghana, Haiti, Ivory Coast, Madagascar, Malawi, Mexico, The Philippines, Rwanda, South Africa, Sri Lanka, Thailand, and Uganda are available for download. We will present a status update and report on lessons learned.

  15. High-resolution spectroscopy of gases for industrial applications

    OpenAIRE

    Fateev, Alexander; Clausen, Sønnik

    2012-01-01

    High-resolution spectroscopy of gases is a powerful technique which has various fundamental and practical applications: in situ simultaneous measurements of gas temperature and gas composition, radiative transfer modeling, validation of existing and developing of new databases and etc. Existing databases (e.g. HITRAN, HITEMP or CDSD) can normally be used for absorption spectra calculations at limited temperature/pressure ranges. Therefore experimental measurements of absorption/transmission s...

  16. High resolution atomic spectra of rare earths : progress report

    International Nuclear Information System (INIS)

    Saksena, G.D.; Ahmad, S.A.

    1976-01-01

    High resolution studies of atomic spectra of neodymium and gadolinium are being carried out on a recording Fabry-Perot spectrometer. The present progress report concerns work done on new assignments as well as confirmation of recently assigned electronic configurations and evaluation of isotope shifts of energy levels which have been possible from the isotope shift data obtained for several transitions of NdI, NdII and GdI, GdII respectively. (author)

  17. High-resolution CT of lesions of the optic nerve

    International Nuclear Information System (INIS)

    Peyster, R.G.; Hoover, E.D.; Hershey, B.L.; Haskin, M.E.

    1983-01-01

    The optic nerves are well demonstrated by high-resolution computed tomography. Involvement of the optic nerve by optic gliomas and optic nerve sheath meningiomas is well known. However, nonneoplastic processes such as increased intracranial pressure, optic neuritis, Grave ophthalmopathy, and orbital pseudotumor may also alter the appearance of the optic nerve/sheath on computed tomography. Certain clinical and computed tomographic features permit distinction of these nonneoplastic tumefactions from tumors

  18. Detectors for high resolution dynamic positron emission tomography

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.; Huesman, R.H.

    1985-01-01

    Tomography is the technique of producing a photographic image of an opaque specimen by transmitting a beam of x-rays or gamma rays through the specimen onto an adjacent photographic film. The image results from variations in thickness, density, and chemical composition, of the specimen. This technique is used to study the metabolism of the human brain. This article examines the design of equipment used for high resolution dynamic positron emission tomography. 27 references, 5 figures, 3 tables

  19. High-Resolution Esophageal Manometry: A Time Motion Study

    Directory of Open Access Journals (Sweden)

    Daniel C Sadowski

    2008-01-01

    Full Text Available INTRODUCTION: High-resolution manometry (HRM of the esophagus is a new technique that provides a more precise assessment of esophageal motility than conventional techniques. Because HRM measures pressure events along the entire length of the esophagus simultaneously, clinical procedure time should be shorter because less catheter manipulation is required. According to manufacturer advertising, the new HRM system is more accurate and up to 50% faster than conventional methods.

  20. High Resolution Mass Spectrometry of Polyfluorinated Polyether-Based Formulation

    DEFF Research Database (Denmark)

    Dimzon, Ian Ken; Trier, Xenia; Frömel, Tobias

    2016-01-01

    High resolution mass spectrometry (HRMS) was successfully applied to elucidate the structure of a polyfluorinated polyether (PFPE)-based formulation. The mass spectrum generated from direct injection into the MS was examined by identifying the different repeating units manually and with the aid o......-fluorinated polymers. The information from MS is essential in studying the physico-chemical properties of PFPEs and can help in assessing the risks they pose to the environment and to human health. Graphical Abstract ᅟ....

  1. Chronic pneumonitis of infancy: high-resolution CT findings

    International Nuclear Information System (INIS)

    Olsen, Oeystein E.; Owens, Catherine M.; Sebire, Neil J.; Jaffe, Adam

    2004-01-01

    Chronic pneumonitis of infancy (CPI) is a very rare entity. We report the chest radiography and high-resolution CT (HRCT) findings in an infant with histopathologically confirmed CPI. The child was admitted for intensive care 18 h after birth and died at 39 days of age. On HRCT there was diffuse ground-glass change, interlobular septal thickening and discrete centrilobular nodules. An accurate diagnosis is crucial for correct management; however, several entities with the same HRCT findings are recognized. (orig.)

  2. Acute pulmonary injury: high-resolution CT and histopathological spectrum

    Science.gov (United States)

    Obadina, E T; Torrealba, J M

    2013-01-01

    Acute lung injury usually causes hypoxaemic respiratory failure and acute respiratory distress syndrome (ARDS). Although diffuse alveolar damage is the hallmark of ARDS, other histopathological patterns of injury, such as acute and fibrinoid organising pneumonia, can be associated with acute respiratory failure. Acute eosinophilic pneumonia can also cause acute hypoxaemic respiratory failure and mimic ARDS. This pictorial essay reviews the high-resolution CT findings of acute lung injury and the correlative histopathological findings. PMID:23659926

  3. Aspects of pulmonary histiocytosis X on high resolution computed tomography

    International Nuclear Information System (INIS)

    Costa, N.S.S.; Castro Lessa Angela, M.T. de; Angelo Junior, J.R.L.; Silva, F.M.D.; Kavakama, J.; Carvalho, C.R.R. de; Cerri, G.G.

    1995-01-01

    Pulmonary histiocytosis X is a disease that occurs in young adults and presents with nodules and cysts, mainly in upper lobes, with consequent pulmonary fibrosis. These pulmonary changes are virtually pathognomonic findings on high resolution computed tomography, that allows estimate the area of the lung involved and distinguish histiocytosis X from other disorders that also produces nodules and cysts. (author). 10 refs, 2 tabs, 6 figs

  4. Concept for a new high resolution high intensity diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Stuhr, U [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A concept of a new time-of-flight powder-diffractometer for a thermal neutral beam tube at SINQ is presented. The design of the instrument optimises the contradictory conditions of high intensity and high resolution. The high intensity is achieved by using many neutron pulses simultaneously. By analysing the time-angle-pattern of the detected neutrons an assignment of the neutrons to a single pulse is possible. (author) 3 figs., tab., refs.

  5. COST EFFECTIVE AND HIGH RESOLUTION SUBSURFACE CHARACTERIZATION USING HYDRAULIC TOMOGRAPHY

    Science.gov (United States)

    2017-08-01

    objective of this project is to provide the DoD and its remediation contractors with the HT technology for delineating the spatial distribution of...STATEMENT Approved for public release; distribution is unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT Hydraulic Tomography ( HT ) is a high-resolution...performance of subsurface remedial actions at environmental sites. The good technical performance and cost-effectiveness of HT have been demonstrated in

  6. High resolution solar soft X-ray spectrometer

    International Nuclear Information System (INIS)

    Zhang Fei; Wang Huanyu; Peng Wenxi; Liang Xiaohua; Zhang Chunlei; Cao Xuelei; Jiang Weichun; Zhang Jiayu; Cui Xingzhu

    2012-01-01

    A high resolution solar soft X-ray spectrometer (SOX) payload onboard a satellite is developed. A silicon drift detector (SDD) is adopted as the detector of the SOX spectrometer. The spectrometer consists of the detectors and their readout electronics, a data acquisition unit and a payload data handling unit. A ground test system is also developed to test SOX. The test results show that the design goals of the spectrometer system have been achieved. (authors)

  7. High-Resolution Wind Measurements for Offshore Wind Energy Development

    Science.gov (United States)

    Nghiem, Son V.; Neumann, Gregory

    2011-01-01

    A mathematical transform, called the Rosette Transform, together with a new method, called the Dense Sampling Method, have been developed. The Rosette Transform is invented to apply to both the mean part and the fluctuating part of a targeted radar signature using the Dense Sampling Method to construct the data in a high-resolution grid at 1-km posting for wind measurements over water surfaces such as oceans or lakes.

  8. Pneumonia: high-resolution CT findings in 114 patients

    Energy Technology Data Exchange (ETDEWEB)

    Reittner, Pia [Department of Radiology, Vancouver Hospital and Health Sciences Center, 855 W. 12th Ave., Vancouver, BC (Canada); Department of Radiology, Karl Franzens University and University Hospital Graz, Auenbruggerplatz 9, 8036 Graz (Austria); Ward, Suzanne; Heyneman, Laura; Mueller, Nestor L. [Department of Radiology, Vancouver Hospital and Health Sciences Center, 855 W. 12th Ave., Vancouver, BC (Canada); Johkoh, Takeshi [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0825 (Japan)

    2003-03-01

    The objective of the present study was to assess the high-resolution CT appearances of different types of pneumonia. The high-resolution CT scans obtained in 114 patients (58 immunocompetent, 59 immunocompromised) with bacterial, Mycoplasma pneumoniae, viral, fungal, and Pneumocystis carinii pneumonias were analyzed retrospectively by two independent observers for presence, pattern, and distribution of abnormalities. Areas of air-space consolidation were not detected in patients with viral pneumonia and were less frequently seen in patients with Pneumocystis carinii pneumonia (2 of 22 patients, 9%) than in bacterial (30 of 35, 85%), Mycoplasma pneumoniae (22 of 28, 79%), and fungal pneumonias (15 of 20, 75%; p<0.01). There was no significant difference in the prevalence or distribution of consolidation between bacterial, Mycoplasma pneumoniae, and fungal pneumonias. Extensive symmetric bilateral areas of ground-glass attenuation were present in 21 of 22 (95%) patients with Pneumocystis carinii pneumonia and were not seen in other pneumonias except in association with areas of consolidation and nodules. Centrilobular nodules were present less commonly in bacterial pneumonia (6 of 35 patients, 17%) than in Mycoplasma pneumoniae (24 of 28, 96%), viral (7 of 9, 78%), or fungal (12 of 20, 92%) pneumonia (p<0.01). Except for Pneumocystis carinii pneumonia and Mycoplasma pneumoniae pneumonia, which often have a characteristic appearance, high-resolution CT is of limited value in the differential diagnosis of the various types of infective pneumonia. (orig.)

  9. High-resolution CT findings in Streptococcus milleri pulmonary infection

    International Nuclear Information System (INIS)

    Okada, F.; Ono, A.; Ando, Y.; Nakayama, T.; Ishii, H.; Hiramatsu, K.; Sato, H.; Kira, A.; Otabe, M.; Mori, H.

    2013-01-01

    Aim: To assess pulmonary high-resolution computed tomography (CT) findings in patients with acute Streptococcus milleri pulmonary infection. Materials and methods: Sixty consecutive patients with acute S. milleri pneumonia who had undergone high-resolution CT chest examinations between January 2004 and March 2010 were retrospectively identified. Twenty-seven patients with concurrent infections were excluded. The final study group comprised 33 patients (25 men, 8 women; aged 20–88 years, mean 63.1 years) with S. milleri infection. The patients' clinical findings were assessed. Parenchymal abnormalities, enlarged lymph nodes, and pleural effusion were evaluated on high-resolution CT. Results: Underlying conditions included malignancy (n = 15), a smoking habit (n = 11), and diabetes mellitus (n = 8). CT images of all patients showed abnormal findings, including ground-glass opacity (n = 24), bronchial wall thickening (n = 23), consolidation (n = 17), and cavities (n = 7). Pleural effusion was found in 18 patients, and complex pleural effusions were found in seven patients. Conclusion: Pulmonary infection caused by S. milleri was observed mostly in male patients with underlying conditions such as malignancy or a smoking habit. The CT findings in patients with S. milleri consisted mainly of ground-glass opacity, bronchial wall thickening, pleural effusions, and cavities

  10. Adaptive optics with pupil tracking for high resolution retinal imaging.

    Science.gov (United States)

    Sahin, Betul; Lamory, Barbara; Levecq, Xavier; Harms, Fabrice; Dainty, Chris

    2012-02-01

    Adaptive optics, when integrated into retinal imaging systems, compensates for rapidly changing ocular aberrations in real time and results in improved high resolution images that reveal the photoreceptor mosaic. Imaging the retina at high resolution has numerous potential medical applications, and yet for the development of commercial products that can be used in the clinic, the complexity and high cost of the present research systems have to be addressed. We present a new method to control the deformable mirror in real time based on pupil tracking measurements which uses the default camera for the alignment of the eye in the retinal imaging system and requires no extra cost or hardware. We also present the first experiments done with a compact adaptive optics flood illumination fundus camera where it was possible to compensate for the higher order aberrations of a moving model eye and in vivo in real time based on pupil tracking measurements, without the real time contribution of a wavefront sensor. As an outcome of this research, we showed that pupil tracking can be effectively used as a low cost and practical adaptive optics tool for high resolution retinal imaging because eye movements constitute an important part of the ocular wavefront dynamics.

  11. The high resolution shear wave seismic reflection technique

    International Nuclear Information System (INIS)

    Johnson, W.J.; Clark, J.C.

    1991-04-01

    This report presents the state-of-the-art of the high resolution S-wave reflection technique. Published and unpublished literature has been reviewed and discussions have been held with experts. Result is to confirm that the proposed theoretical and practical basis for identifying aquifer systems using both P- and S-wave reflections is sound. Knowledge of S-wave velocity and P-wave velocity is a powerful tool for assessing the fluid characteristics of subsurface layers. Material properties and lateral changes in material properties such as change from clay to sand, can be inferred from careful dual evaluation of P and S-wave records. The high resolution S-wave reflection technique has seen its greatest application to date as part of geotechnical studies for building foundations in the Far East. Information from this type of study has been evaluated and will be incorporated in field studies. In particular, useful information regarding S-wave sources, noise suppression and recording procedures will be incorporated within the field studies. Case histories indicate that the best type of site for demonstrating the power of the high resolution S-wave technique will be in unconsolidated soil without excessive structural complexities. More complex sites can form the basis for subsequent research after the basic principles of the technique can be established under relatively uncomplicated conditions

  12. Pneumonia: high-resolution CT findings in 114 patients

    International Nuclear Information System (INIS)

    Reittner, Pia; Ward, Suzanne; Heyneman, Laura; Mueller, Nestor L.; Johkoh, Takeshi

    2003-01-01

    The objective of the present study was to assess the high-resolution CT appearances of different types of pneumonia. The high-resolution CT scans obtained in 114 patients (58 immunocompetent, 59 immunocompromised) with bacterial, Mycoplasma pneumoniae, viral, fungal, and Pneumocystis carinii pneumonias were analyzed retrospectively by two independent observers for presence, pattern, and distribution of abnormalities. Areas of air-space consolidation were not detected in patients with viral pneumonia and were less frequently seen in patients with Pneumocystis carinii pneumonia (2 of 22 patients, 9%) than in bacterial (30 of 35, 85%), Mycoplasma pneumoniae (22 of 28, 79%), and fungal pneumonias (15 of 20, 75%; p<0.01). There was no significant difference in the prevalence or distribution of consolidation between bacterial, Mycoplasma pneumoniae, and fungal pneumonias. Extensive symmetric bilateral areas of ground-glass attenuation were present in 21 of 22 (95%) patients with Pneumocystis carinii pneumonia and were not seen in other pneumonias except in association with areas of consolidation and nodules. Centrilobular nodules were present less commonly in bacterial pneumonia (6 of 35 patients, 17%) than in Mycoplasma pneumoniae (24 of 28, 96%), viral (7 of 9, 78%), or fungal (12 of 20, 92%) pneumonia (p<0.01). Except for Pneumocystis carinii pneumonia and Mycoplasma pneumoniae pneumonia, which often have a characteristic appearance, high-resolution CT is of limited value in the differential diagnosis of the various types of infective pneumonia. (orig.)

  13. The demonstration of the auditory ossicles by high resolution CT

    International Nuclear Information System (INIS)

    Lloyd, G.A.S.; Boulay, G.H. du; Phelps, P.D.; Pullicino, P.

    1979-01-01

    The high resolution CT scanning system introduced by EMI in 1978 has added a new dimension to computerised tomography in otology. The apparatus used for this study was an EMI CT 5005 body scanner adapted for head and neck scanning and incorporating a high resolution facility. The latter has proved most advantageous in areas of relatively high differential absorption, so that its application to the demonstration of abnormalities in the petrous temporal bone, and in particular middle ear disease, has been very rewarding. Traumatic ossicular disruptions may now be demonstrated and the high contrast of CT often shows them better than conventional hypocycloidal tomography. The stapes is also better visualised and congenital abnormalities of its superstructure have been recorded. These studies have been achieved with a very acceptable level of radiation to the eye, lens and cornea and the technique is clearly a rival to conventional pluridirectional tomography in the assessment of the petrous temporal bone. With further design improvements high resolution CT could completely replace existing techniques. (orig.) [de

  14. Progress in high-resolution x-ray holographic microscopy

    International Nuclear Information System (INIS)

    Jacobsen, C.; Kirz, J.; Howells, M.; McQuaid, K.; Rothman, S.; Feder, R.; Sayre, D.

    1987-07-01

    Among the various types of x-ray microscopes that have been demonstrated, the holographic microscope has had the largest gap between promise and performance. The difficulties of fabricating x-ray optical elements have led some to view holography as the most attractive method for obtaining the ultimate in high resolution x-ray micrographs; however, we know of no investigations prior to 1987 that clearly demonstrated submicron resolution in reconstructed images. Previous efforts suffered from problems such as limited resolution and dynamic range in the recording media, low coherent x-ray flux, and aberrations and diffraction limits in visible light reconstruction. We have addressed the recording limitations through the use of an undulator x-ray source and high-resolution photoresist recording media. For improved results in the readout and reconstruction steps, we have employed metal shadowing and transmission electron microscopy, along with numerical reconstruction techniques. We believe that this approach will allow holography to emerge as a practical method of high-resolution x-ray microscopy. 30 refs., 4 figs

  15. Toward high-resolution NMR spectroscopy of microscopic liquid samples

    Energy Technology Data Exchange (ETDEWEB)

    Butler, Mark C.; Mehta, Hardeep S.; Chen, Ying; Reardon, Patrick N.; Renslow, Ryan S.; Khbeis, Michael; Irish, Duane; Mueller, Karl T.

    2017-01-01

    A longstanding limitation of high-resolution NMR spectroscopy is the requirement for samples to have macroscopic dimensions. Commercial probes, for example, are designed for volumes of at least 5 mL, in spite of decades of work directed toward the goal of miniaturization. Progress in miniaturizing inductive detectors has been limited by a perceived need to meet two technical requirements: (1) minimal separation between the sample and the detector, which is essential for sensitivity, and (2) near-perfect magnetic-field homogeneity at the sample, which is typically needed for spectral resolution. The first of these requirements is real, but the second can be relaxed, as we demonstrate here. By using pulse sequences that yield high-resolution spectra in an inhomogeneous field, we eliminate the need for near-perfect field homogeneity and the accompanying requirement for susceptibility matching of microfabricated detector components. With this requirement removed, typical imperfections in microfabricated components can be tolerated, and detector dimensions can be matched to those of the sample, even for samples of volume << 5 uL. Pulse sequences that are robust to field inhomogeneity thus enable small-volume detection with optimal sensitivity. We illustrate the potential of this approach to miniaturization by presenting spectra acquired with a flat-wire detector that can easily be scaled to subnanoliter volumes. In particular, we report high-resolution NMR spectroscopy of an alanine sample of volume 500 pL.

  16. Progress in high-resolution x-ray holographic microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, C.; Kirz, J.; Howells, M.; McQuaid, K.; Rothman, S.; Feder, R.; Sayre, D.

    1987-07-01

    Among the various types of x-ray microscopes that have been demonstrated, the holographic microscope has had the largest gap between promise and performance. The difficulties of fabricating x-ray optical elements have led some to view holography as the most attractive method for obtaining the ultimate in high resolution x-ray micrographs; however, we know of no investigations prior to 1987 that clearly demonstrated submicron resolution in reconstructed images. Previous efforts suffered from problems such as limited resolution and dynamic range in the recording media, low coherent x-ray flux, and aberrations and diffraction limits in visible light reconstruction. We have addressed the recording limitations through the use of an undulator x-ray source and high-resolution photoresist recording media. For improved results in the readout and reconstruction steps, we have employed metal shadowing and transmission electron microscopy, along with numerical reconstruction techniques. We believe that this approach will allow holography to emerge as a practical method of high-resolution x-ray microscopy. 30 refs., 4 figs.

  17. High resolution solar observations from first principles to applications

    Science.gov (United States)

    Verdoni, Angelo P.

    2009-10-01

    The expression "high-resolution observations" in Solar Physics refers to the spatial, temporal and spectral domains in their entirety. High-resolution observations of solar fine structure are a necessity to answer many of the intriguing questions related to solar activity. However, a researcher building instruments for high-resolution observations has to cope with the fact that these three domains often have diametrically opposed boundary conditions. Many factors have to be considered in the design of a successful instrument. Modern post-focus instruments are more closely linked with the solar telescopes that they serve than in past. In principle, the quest for high-resolution observations already starts with the selection of the observatory site. The site survey of the Advanced Technology Solar Telescope (ATST) under the stewardship of the National Solar Observatory (NSO) has identified Big Bear Solar Observatory (BBSO) as one of the best sites for solar observations. In a first step, the seeing characteristics at BBSO based on the data collected for the ATST site survey are described. The analysis will aid in the scheduling of high-resolution observations at BBSO as well as provide useful information concerning the design and implementation of a thermal control system for the New Solar Telescope (NST). NST is an off-axis open-structure Gregorian-style telescope with a 1.6 m aperture. NST will be housed in a newly constructed 5/8-sphere ventilated dome. With optics exposed to the surrounding air, NST's open-structure design makes it particularly vulnerable to the effects of enclosure-related seeing. In an effort to mitigate these effects, the initial design of a thermal control system for the NST dome is presented. The goal is to remediate thermal related seeing effects present within the dome interior. The THermal Control System (THCS) is an essential component for the open-telescope design of NST to work. Following these tasks, a calibration routine for the

  18. A subspace approach to high-resolution spectroscopic imaging.

    Science.gov (United States)

    Lam, Fan; Liang, Zhi-Pei

    2014-04-01

    To accelerate spectroscopic imaging using sparse sampling of (k,t)-space and subspace (or low-rank) modeling to enable high-resolution metabolic imaging with good signal-to-noise ratio. The proposed method, called SPectroscopic Imaging by exploiting spatiospectral CorrElation, exploits a unique property known as partial separability of spectroscopic signals. This property indicates that high-dimensional spectroscopic signals reside in a very low-dimensional subspace and enables special data acquisition and image reconstruction strategies to be used to obtain high-resolution spatiospectral distributions with good signal-to-noise ratio. More specifically, a hybrid chemical shift imaging/echo-planar spectroscopic imaging pulse sequence is proposed for sparse sampling of (k,t)-space, and a low-rank model-based algorithm is proposed for subspace estimation and image reconstruction from sparse data with the capability to incorporate prior information and field inhomogeneity correction. The performance of the proposed method has been evaluated using both computer simulations and phantom studies, which produced very encouraging results. For two-dimensional spectroscopic imaging experiments on a metabolite phantom, a factor of 10 acceleration was achieved with a minimal loss in signal-to-noise ratio compared to the long chemical shift imaging experiments and with a significant gain in signal-to-noise ratio compared to the accelerated echo-planar spectroscopic imaging experiments. The proposed method, SPectroscopic Imaging by exploiting spatiospectral CorrElation, is able to significantly accelerate spectroscopic imaging experiments, making high-resolution metabolic imaging possible. Copyright © 2014 Wiley Periodicals, Inc.

  19. Landslide detection using very high-resolution satellite imageries

    Science.gov (United States)

    Suga, Yuzo; Konishi, Tomohisa

    2012-10-01

    The heavy rain induced by the 12th typhoon caused landslide disaster at Kii Peninsula in the middle part of Japan. We propose a quick response method for landslide disaster mapping using very high resolution (VHR) satellite imageries. Especially, Synthetic Aperture Radar (SAR) is effective because it has the capability of all weather and day/night observation. In this study, multi-temporal COSMO-SkyMed imageries were used to detect the landslide areas. It was difficult to detect the landslide areas using only backscatter change pattern derived from pre- and post-disaster COSMOSkyMed imageries. Thus, the authors adopted a correlation analysis which the moving window was selected for the correlation coefficient calculation. Low value of the correlation coefficient reflects land cover change between pre- and post-disaster imageries. This analysis is effective for the detection of landslides using SAR data. The detected landslide areas were compared with the area detected by EROS-B high resolution optical image. In addition, we have developed 3D viewing system for geospatial visualizing of the damaged area using these satellite image data with digital elevation model. The 3D viewing system has the performance of geographic measurement with respect to elevation height, area and volume calculation, and cross section drawing including landscape viewing and image layer construction using a mobile personal computer with interactive operation. As the result, it was verified that a quick response for the detection of landslide disaster at the initial stage could be effectively performed using optical and SAR very high resolution satellite data by means of 3D viewing system.

  20. Proceedings of the workshop on high resolution computed microtomography (CMT)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-02-01

    The purpose of the workshop was to determine the status of the field, to define instrumental and computational requirements, and to establish minimum specifications required by possible users. The most important message sent by implementers was the remainder that CMT is a tool. It solves a wide spectrum of scientific problems and is complementary to other microscopy techniques, with certain important advantages that the other methods do not have. High-resolution CMT can be used non-invasively and non-destructively to study a variety of hierarchical three-dimensional microstructures, which in turn control body function. X-ray computed microtomography can also be used at the frontiers of physics, in the study of granular systems, for example. With high-resolution CMT, for example, three-dimensional pore geometries and topologies of soils and rocks can be obtained readily and implemented directly in transport models. In turn, these geometries can be used to calculate fundamental physical properties, such as permeability and electrical conductivity, from first principles. Clearly, use of the high-resolution CMT technique will contribute tremendously to the advancement of current R and D technologies in the production, transport, storage, and utilization of oil and natural gas. It can also be applied to problems related to environmental pollution, particularly to spilling and seepage of hazardous chemicals into the Earth's subsurface. Applications to energy and environmental problems will be far-ranging and may soon extend to disciplines such as materials science--where the method can be used in the manufacture of porous ceramics, filament-resin composites, and microelectronics components--and to biomedicine, where it could be used to design biocompatible materials such as artificial bones, contact lenses, or medication-releasing implants. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  1. High Resolution Thz and FIR Spectroscopy of SOCl_2

    Science.gov (United States)

    Martin-Drumel, M. A.; Cuisset, A.; Sadovskii, D. A.; Mouret, G.; Hindle, F.; Pirali, O.

    2013-06-01

    Thionyl chloride (SOCl_2) is an extremely powerful oxidant widely used in industrial processes and playing a role in the chemistry of the atmosphere. In addition, it has a molecular configuration similar to that of phosgene (COCl_2), and is therefore of particular interest for security and defense applications. Low resolution vibrational spectra of gas phase SOCl_2 as well as high resolution pure rotational transitions up to 25 GHz have previously been investigated. To date no high resolution data are reported at frequencies higher than 25 GHz. We have investigated the THz absorption spectrum of SOCl_2 in the spectral region 70-650 GHz using a frequency multiplier chain coupled to a 1 m long single path cell containing a pressure of about 15 μbar. At the time of the writing, about 8000 pure rotational transitions of SO^{35}Cl_2 with highest J and K_a values of 110 and 50 respectively have been assigned on the spectrum. We have also recorded the high resolution FIR spectra of SOCl_2 in the spectral range 50-700 wn using synchrotron radiation at the AILES beamline of SOLEIL facility. A White-type cell aligned with an absorption path length of 150 m has been used to record, at a resolution of 0.001 wn, two spectra at pressures of 5 and 56 μbar of SOCl_2. On these spectra all FIR modes of SOCl_2 are observed (ν_2 to ν_6) and present a resolved rotational structure. Their analysis is in progress. T. J. Johnson et al., J. Phys. Chem. A 107, 6183 (2003) D. E. Martz and R. T. Lagemann, J. Chem. Phys. 22,1193 (1954) H. S. P. Müller and M. C. L. Gerry, J. Chem. Soc. Faraday Trans. 90, 3473 (1994)

  2. Geological survey by high resolution electrical survey on granite areas

    International Nuclear Information System (INIS)

    Sugimoto, Yoshihiro; Yamada, Naoyuki

    2002-03-01

    As an Integral part of the geological survey in 'The study of the regions ground water flow system' that we are carrying out with Tono Geoscience Center, we proved the relation between the uncontinuation structure such as lineament in the base rock and resistivity structure (resistivity distribution), for the purpose of that confirms the efficacy of the high resolution electrical survey as geological survey, we carried out high resolution electrical survey on granite area. We obtained the following result, by the comparison of resistivity distribution with established geological survey, lineament analysis and investigative drilling. 1. The resistivity structure of this survey area is almost able to classify it into the following four range. 1) the low resistivity range of 50-800 Ωm, 2) The resistivity range like the middle of 200-2000 Ωm, 3) The high resistivity range of 2000 Ωm over, 4) The low resistivity range of depth of the survey line 400-550 section. 2. The low resistivity range of 4) that correspond with the established geological data is not admitted. 3. It was confirmed that resistivity structure almost correspond to geological structure by the comparison with the established data. 4. The small-scale low resistivity area is admitted in the point equivalent to the lineament position of established. 5. We carried out it with the simulation method about the low resistivity range of 4). As a result, it understood that it has the possibility that the narrow ratio low resistivity area is shown as the wide ratio resistivity range in the analysis section. In the survey in this time, it is conceivable that the resistivity distribution with the possibility of the unhomogeneous and uncontinuation structure of the base rock is being shown conspicuously, the efficacy of the high resolution resistivity survey as geological survey on granite was shown. (author)

  3. High-resolution ultrasonography in assessing temporomandibular joint disc position.

    Science.gov (United States)

    Talmaceanu, Daniel; Lenghel, Lavinia Manuela; Bolog, Nicolae; Popa Stanila, Roxana; Buduru, Smaranda; Leucuta, Daniel Corneliu; Rotar, Horatiu; Baciut, Mihaela; Baciut, Grigore

    2018-02-04

    The purpose of this study was to determine the diagnostic value of high-resolution ultrasonography (US) in temporomandibular joint (TMJ) disc displacements. A number of 74 patients (148 TMJs) with signs and symptoms of TMJ disorders, according to the Research Diagnostic Criteria for Temporomandibular Disorders, were included in this study. All patients received US and magnetic resonance imaging (MRI) of both TMJs 1 to 5 days after the clinical examination. MRI examinations were performed using 1.5 T MRI equipment (Siemens Avanto, Siemens, Erlangen). Ultrasonographic examination was performed on a Hitachi EUB 8500 (Hitachi Medical Corp., Tokyo, Japan) scanner with L 54 M6.5-13 MHz linear transducer. MRI depicted 68 (45.95%) normal joints, 47 (31.76%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 34 (22.97%) with degenerative changes. US detected 78 (52.7%) normal joints, 37 (25%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 21 (14.19%) with degenerative changes. Compared to MRI, US showed a sensitivity of 93.1%, specificity of 87.88%, accuracy of 90.32%, a positive predictive value of 87.1% and a negative predictive value of 93.55% for overall diagnosis of disc displacement. The Youden index was 0.81. Based on our results, high-resolution ultrasonography showed high sensitivity, specificity and accuracy in the diagnosis of TMJ disc displacement. It could be a valuable imaging technique in assessing TMJ disc position. The diagnostic value of high-resolution ultrasonography depends strictly on the examiner's skills and on the equipment used.

  4. On temporal correlations in high-resolution frequency counting

    OpenAIRE

    Dunker, Tim; Hauglin, Harald; Rønningen, Ole Petter

    2016-01-01

    We analyze noise properties of time series of frequency data from different counting modes of a Keysight 53230A frequency counter. We use a 10 MHz reference signal from a passive hydrogen maser connected via phase-stable Huber+Suhner Sucoflex 104 cables to the reference and input connectors of the counter. We find that the high resolution gap-free (CONT) frequency counting process imposes long-term correlations in the output data, resulting in a modified Allan deviation that is characteristic...

  5. High Resolution Spectrometer (HRS) particle-identification system

    International Nuclear Information System (INIS)

    Pratt, J.C.; Spencer, J.E.; Whitten, C.A.

    1977-08-01

    The functions of the particle-identification system (PIDS) designed for the High Resolution Spectrometer facility (HRS) at LAMPF are described, together with the mechanical layout, counter hardware, and associated electronics. The system was designed for easy use and to be applicable to currently proposed experiments at HRS. The several strobe signals that can be generated correspond to different event types or characteristics, and logic configuration and timing can be remotely controlled by computer. Concepts of discrete pattern recognition and multidimensional, analog pulse discrimination are used to distinguish between different event types

  6. Computing with high-resolution upwind schemes for hyperbolic equations

    International Nuclear Information System (INIS)

    Chakravarthy, S.R.; Osher, S.; California Univ., Los Angeles)

    1985-01-01

    Computational aspects of modern high-resolution upwind finite-difference schemes for hyperbolic systems of conservation laws are examined. An operational unification is demonstrated for constructing a wide class of flux-difference-split and flux-split schemes based on the design principles underlying total variation diminishing (TVD) schemes. Consideration is also given to TVD scheme design by preprocessing, the extension of preprocessing and postprocessing approaches to general control volumes, the removal of expansion shocks and glitches, relaxation methods for implicit TVD schemes, and a new family of high-accuracy TVD schemes. 21 references

  7. Achieving High Resolution Timer Events in Virtualized Environment.

    Science.gov (United States)

    Adamczyk, Blazej; Chydzinski, Andrzej

    2015-01-01

    Virtual Machine Monitors (VMM) have become popular in different application areas. Some applications may require to generate the timer events with high resolution and precision. This however may be challenging due to the complexity of VMMs. In this paper we focus on the timer functionality provided by five different VMMs-Xen, KVM, Qemu, VirtualBox and VMWare. Firstly, we evaluate resolutions and precisions of their timer events. Apparently, provided resolutions and precisions are far too low for some applications (e.g. networking applications with the quality of service). Then, using Xen virtualization we demonstrate the improved timer design that greatly enhances both the resolution and precision of achieved timer events.

  8. Free radicals. High-resolution spectroscopy and molecular structure

    International Nuclear Information System (INIS)

    Hirota, E.

    1983-01-01

    High-resolution, high-sensitivity spectroscopy using CW laser and microwave sources has been applied to free radicals and transient molecules to establish their existence and to explore their properties in detail. The radicals studied were mainly generated by discharge-induced reactions. A few molecules are used as typical examples to illustrate the results so far obtained. The molecular and electronic structures of free radicals, intramolecular motions of large amplitudes in some labile molecules, and metastable electronic states of carbenes are given special emphasis. The significance of the present spectroscopic results in other related fields such as astronomy and atmospheric chemistry is stressed. 4 figures, 3 tables

  9. High resolution spectroscopy of six new extreme helium stars

    Science.gov (United States)

    Heber, U.; Jones, G.; Drilling, J. S.

    1986-01-01

    High resolution spectra of six newly discovered extreme helium stars are presented. LSS 5121 is shown to be a spectroscopical twin of the hot extreme helium star HD 160641. A preliminary LTE analysis of LSS 3184 yielded an effective temperature of 22,000 K and a surface gravity of log g = 3.2. Four stars form a new subgroup, classified by sharp-lined He I spectra and pronounced O II spectra, and it is conjectured that these lie close to the Eddington limit. The whole group of extreme helium stars apparently is inhomogeneous with respect to luminosity to mass ratio and chemical composition.

  10. High resolution laser spectroscopy as a diagnostic tool in beams

    International Nuclear Information System (INIS)

    Bergmann, K.; Hefter, U.; Hering, P.

    1977-01-01

    The combination of high resolution laser spectroscopy with the technique of molecular beams allows a very detailed beam research since molecules or atoms in specific quantum states can be sampled yielding previously unavailable sources of data. In these experiments a Na/Na 2 beam emerges from a 0.2 mm nozzle and is collimated by a 2 mm wide slit 50 cm downstream. To probe the molecules a single mode Ar + -laser was used which can be tuned within the gain profile of the laser line (8 GHz) to several transitions between specific levels in the ground state and second electronically excited state of the Na 2 molecule. (Auth.)

  11. High resolution skin colorimetry, strain mapping and mechanobiology.

    Science.gov (United States)

    Devillers, C; Piérard-Franchimont, C; Schreder, A; Docquier, V; Piérard, G E

    2010-08-01

    Skin colours are notoriously different between individuals. They are governed by ethnicities and phototypes, and further influenced by a variety of factors including photoexposures and sustained mechanical stress. Indeed, mechanobiology is a feature affecting the epidermal melanization. High-resolution epiluminescence colorimetry helps in deciphering the effects of forces generated by Langer's lines or relaxed skin tension lines on the melanocyte activity. The same procedure shows a prominent laddering pattern of melanization in striae distensae contrasting with the regular honeycomb pattern in the surrounding skin.

  12. Diesel characterization by high-resolution mass spectrometry - gas chromatography

    International Nuclear Information System (INIS)

    Baldrich, C.A

    1998-01-01

    High-resolution mass spectrometry-gas chromatography is combined with the HC22 method in order to obtain detailed information about the chemical composition of diesel and the distribution of different compound types in terms of its final boiling temperature from a single analysis. The total time elapsed from sample injection and signal processing to obtain final results is 90 minutes. This fact makes this methodology a new and very important tool for the decision making process concerning the most suitable final boiling temperature and the type of treatment of the product in order to obtain diesel that fulfills the international standards. The consistency and repeatability of the experimental results are demonstrated

  13. New detector developments for high resolution positron emission tomography

    International Nuclear Information System (INIS)

    Ziegler, S.I.; Pichler, B.; Lorenz, E.

    1998-01-01

    The strength of quantitative, functional imaging using positron emission tomography, specially in small animals, is limited due to the spatial resolution. Therefore, various tomograph designs employing new scintillators, light sensors, or coincidence electronic are investigated to improve resolution without losses in sensitivity. Luminous scintillators with short light decay time in combination with novel readout schemes using photomultipliers or semiconductor detectors are currently tested by several groups and are implemented in tomographs for small animals. This review summarises the state of development in high resolution positron emission tomography with a detailed description of a system incorporating avalanche photodiode arrays and small scintillation crystals. (orig.) [de

  14. High resolution upgrade of the ATF damping ring BPM system

    International Nuclear Information System (INIS)

    Terunuma, N.; Urakawa, J.; Frisch, J.; May, J.; McCormick, D.; Nelson, J.; Seryi, A.; Smith, T.; Woodley, M.; Briegel, C.; Dysert, R.

    2008-01-01

    A beam position monitor (BPM) upgrade at the KEK Accelerator Test Facility (ATF) damping ring has been accomplished in its first stage, carried out by a KEK/FNAL/SLAC collaboration under the umbrella of the global ILC R and D effort. The upgrade consists of a high resolution, high reproducibility read-out system, based on analog and digital downconversion techniques, digital signal processing, and also tests a new automatic gain error correction schema. The technical concept and realization, as well as preliminary results of beam studies are presented

  15. High-resolution neutron-diffraction measurements to 8 kbar

    Science.gov (United States)

    Bull, C. L.; Fortes, A. D.; Ridley, C. J.; Wood, I. G.; Dobson, D. P.; Funnell, N. P.; Gibbs, A. S.; Goodway, C. M.; Sadykov, R.; Knight, K. S.

    2017-10-01

    We describe the capability to measure high-resolution neutron powder diffraction data to a pressure of at least 8 kbar. We have used the HRPD instrument at the ISIS neutron source and a piston-cylinder design of pressure cell machined from a null-scattering titanium zirconium alloy. Data were collected under hydrostatic conditions from an elpasolite perovskite La?NiMnO?; by virtue of a thinner cell wall on the incident-beam side of the cell, it was possible to obtain data in the instrument's highest resolution back-scattering detector banks up to a maximum pressure of 8.5 kbar.

  16. Diagnosis of cholesteatoma by high resolution computed tomography

    International Nuclear Information System (INIS)

    Kakitsubata, Yousuke; Kakitsubata, Sachiko; Ogata, Noboru; Asada, Keiko; Watanabe, Katsushi; Tohno, Tetsuya; Makino, Kohji

    1988-01-01

    Three normal volunteers and 57 patients with cholesteatoma were examined by high resolution computed tomography. Serial sections were made through the temporal bone at the nasaly inclined position of 30 degree to the orbitomeatal line (semiaxial plane ; SAP). The findings of temporal bone structures in normal subjects were evaluated in SAP and axial plane (OM). Although the both planes showed good visualization, SAP showed both the eustachian tube and tympanic cavity in one slice. In cholesteatoma soft tissue masses in the tympanic cavity, mastoid air cells and Eustachian tube were demonstrated clearly by SAP. (author)

  17. High resolution Moessbauer spectroscopy with 67Zn in metallic systems

    International Nuclear Information System (INIS)

    Potzel, W.

    1985-01-01

    Moessbauer experiments on metallic systems are described where the high resolution 93.3 keV resonance in 67 Zn is used. In the first part, the Cu-Zn alloy system is investigated and the high energy resolution of this Moessbauer transition is employed to determine small changes of the s-electron density at the 67 Zn nucleus when the Zn concentration is changed. In the second part, Zn metal is taken as an example to demonstrate that the 93.3 keV transition is also extremely sensitive to small changes of lattice dynamical effects. 7 refs., 18 figs. (author)

  18. Evaluation of high-resolution CT after tympanoplasty

    International Nuclear Information System (INIS)

    Torizuka, T.; Hayakawa, K.; Sato, Y.; Tanaka, F.; Okuno, Y.

    1991-01-01

    This paper reports on the condition of the middle ear cavity following tympanoplasty which is always of great interest to radiologists and otosurgeons. This study consisted of 21 patients who had various types of tympanoplasty (types I-IV) for chronic otitis media and cholesteatoma by using high-resolution CT (HRCT). HRCT following tympanoplasty was a valuable method for assessing the middle ear aeration and the state of ossicular reconstruction, including stapes prosthesis, although in some cases of soft-tissue mass in the middle ear it was necessary to correlate with clinical findings in order to differentiate between granulation and recurrence

  19. High resolution X-ray spectroscopy of thermal plasmas

    International Nuclear Information System (INIS)

    Canizares, C.R.

    1990-01-01

    This paper concentrates on reviewing highlights of the Focal Plane Crystal Spectrometer (FPCS) results on thermal plasmas, particularly supernova remnants (SNRs) and clusters of galaxies from the Einstein observatory. During Einstein's short but happy life, we made over 400 observations with the FPCS of 40 different objects. Three quarters of these were objects in which the emission was primarily from optically thin thermal plasma, primarily supernova remnants (SNRs) and clusters of galaxies. Thermal plasmas provide an excellent illustration of how spectral data, particularly high resolution spectral data, can be an important tool for probing the physical properties of astrophysical objects. (author)

  20. High-resolution CT of lymphoid interstitial pneumonia

    International Nuclear Information System (INIS)

    Vilgrain, V.; Frija, J.; Yana, C.; Couderc, L.J.; David, M.; Clauvel, J.P.; Laval-Jeantet, M.

    1989-01-01

    Three patients with lymphoid interstitial pneumonia (two HIV 1+ patients with chronic lymphadenopathic syndromes and one with a not-characterized autoimmune disease) have been studied with high-resolution computed tomography (HR-CT). This technique reveals septal lines, small reticulonodular opacities, polyhedral micronodular opacities, 'ground-glass' opacities and a dense, subpleural, curved broken line in one patient. The lesions dominate in the bases of the lungs. They are not characteristic for lymphoid interstitial pneumonia. If a patient presents with a chronic lymphadenopathic syndrome, the diagnosis of an opportunistic infection should not be automatically made, since the syndrome can be caused by lymphoid interstitial pneumonia [fr

  1. Intercalibration of the ZEUS high resolution and backing calorimeters

    International Nuclear Information System (INIS)

    Abramowicz, H.; Czyrkowski, H.; Derlicki, A.; Krzyzanowski, M.; Kudla, I.; Kusmierz, W.; Nowak, R.J.; Pawlak, J.M.; Rajca, A.; Stopczynski, A.; Walczak, R.; Zarnecki, A.F.; Kowalski, T.Z.

    1991-07-01

    We have studied the combined performance of two calorimeters, the high resolution uranium-scintillator prototype of the ZEUS forward calorimeter (FCAL), followed by a prototype of the coarser ZEUS backing calorimeter (BAC), made out of thick iron plates interleaved with planes of aluminium proportional chambers. The test results, obtained in an exposure of the calorimeter system to a hadron test beam at the CERN-SPS, show that the backing calorimeter does fulfil its role of recognizing the energy leaking out of the FCAL calorimeter. The measurement of this energy is feasible, if an appropriate calibration of the BAC calorimeter is performed. (orig.)

  2. High-resolution seismic wave propagation using local time stepping

    KAUST Repository

    Peter, Daniel

    2017-03-13

    High-resolution seismic wave simulations often require local refinements in numerical meshes to accurately capture e.g. steep topography or complex fault geometry. Together with explicit time schemes, this dramatically reduces the global time step size for ground-motion simulations due to numerical stability conditions. To alleviate this problem, local time stepping (LTS) algorithms allow an explicit time stepping scheme to adapt the time step to the element size, allowing nearoptimal time steps everywhere in the mesh. This can potentially lead to significantly faster simulation runtimes.

  3. High resolution resistivity measurements at the Down Ampney research site

    International Nuclear Information System (INIS)

    Hallam, J.R.; Jackson, P.D.; Rainsbury, M.; Raines, M.

    1991-01-01

    A new high resolution resistivity surveying method is described for fault detection and characterisation. The resolution is shown to be significantly higher than conventional apparent resistivity profiling when applied to geological discontinuities such as faults. Nominal fault locations have been determined to an accuracy of 0.5 m, as proven by drilling. Two dimensional profiling and image enhancement of the resulting 2-D data set indicated the possibility of subsidiary fractures and/or lateral changes within the clay to clay' fault zone. The increased resolution allows greater confidence to be placed on both the fault detection and lateral perturbations derived from processed resistance and resistivity images. (Author)

  4. High resolution SPM imaging of organic molecules with functionalized tips

    Czech Academy of Sciences Publication Activity Database

    Jelínek, Pavel

    2017-01-01

    Roč. 29, č. 34 (2017), 1-18, č. článku 343002. ISSN 0953-8984 R&D Projects: GA MŠk LM2015087; GA MŠk 8E15B010; GA ČR(CZ) GC14-16963J Grant - others:AV ČR(CZ) Praemium Academiae Institutional support: RVO:68378271 Keywords : atomic- force microscopy * scanning tunneling microscope * on-surface synthesis * single-molecule * AFM * STM * high resolution * molecules * surfaces Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 2.649, year: 2016

  5. High-resolution x-ray photoemission spectra of silver

    DEFF Research Database (Denmark)

    Barrie, A.; Christensen, N. E.

    1976-01-01

    An electron spectrometer fitted with an x-ray monochromator for Al Kα1,2 radiation (1486.6 eV) has been used to record high-resolution x-ray photoelectron spectra for the 4d valence band as well as the 3d spin doublet in silver. The core-level spectrum has a line shape that can be described...... successfully in terms of the many-body theory of Mahan, Nozières, and De Dominicis. The 4d spectrum agrees well with predictions based on a relativistic-augmented-plane-wave band-structure calculation....

  6. Intercalibration of the ZEUS high resolution and backing calorimeters

    International Nuclear Information System (INIS)

    Abramowicz, H.; Czyrkowski, H.; Derlicki, A.; Krzyzanowski, M.; Kudla, I.; Kusmierz, W.; Nowak, R.J.; Pawlak, J.M.; Rajca, A.; Stopczynski, A.; Walczak, R.; Zarnecki, A.F.; Kowalski, T.Z.

    1992-01-01

    We have studied the combined performance of two calorimeters, the high resolution uranium-scintillator prototype of the ZEUS forward calorimeter (FCAL), followed by a prototype of the coarser ZEUS backing calorimeter (BAC), made out of thick iron plates interleaved with planes of aluminium proportional chambers. The test results, obtained in an exposure of the calorimeter system to a hadron test beam at the CERN SPS, show that the backing calorimeter does fulfil its role of recognizing the energy leaking out of the FCAL calorimeter. The measurement of this energy is feasible, if an appropriate calibration of the BAC calorimeter is performed. (orig.)

  7. Clickstream data yields high-resolution maps of science

    Energy Technology Data Exchange (ETDEWEB)

    Bollen, Johan [Los Alamos National Laboratory; Van De Sompel, Herbert [Los Alamos National Laboratory; Hagberg, Aric [Los Alamos National Laboratory; Bettencourt, Luis [Los Alamos National Laboratory; Chute, Ryan [Los Alamos National Laboratory; Rodriguez, Marko A [Los Alamos National Laboratory; Balakireva, Lyudmila [Los Alamos National Laboratory

    2009-01-01

    Intricate maps of science have been created from citation data to visualize the structure of scientific activity. However, most scientific publications are now accessed online. Scholarly web portals record detailed log data at a scale that exceeds the number of all existing citations combined. Such log data is recorded immediately upon publication and keeps track of the sequences of user requests (clickstreams) that are issued by a variety of users across many different domains. Given these advantagees of log datasets over citation data, we investigate whether they can produce high-resolution, more current maps of science.

  8. High resolution X-ray spectroscopy in light antiprotonic atoms

    CERN Document Server

    Borchert, G L; Augsburger, M A; Castelli, C M; Chatellard, D; Egger, J P; El-Khoury, P; Elble, M; Gorke, H; Gotta, D; Hauser, P R; Indelicato, P J; Kirch, K; Lenz, S; Nelms, N; Rashid, K; Schult, O W B; Siems, T; Simons, L M

    2000-01-01

    At the LEAR facility, CERN, antiprotonic L alpha transitions in light elements have been investigated with a focussing crystal spectrometer. The high resolution of the experiment allowed for the first time to resolve in pH/pH the 2/sup 3/P/sub 0/ state from the close-lying states 2/sup 3/P/sub 2/, 2/sup 1/P/sub 1/, and 2/sup 3/P /sub 1/. In pD the corresponding transitions were found to be more than an order of magnitude broader. To a large extent the results for pH support the meson exchange model. (15 refs).

  9. High resolution multiplexed functional imaging in live embryos (Conference Presentation)

    Science.gov (United States)

    Xu, Dongli; Zhou, Weibin; Peng, Leilei

    2017-02-01

    Fourier multiplexed fluorescence lifetime imaging (FmFLIM) scanning laser optical tomography (FmFLIM-SLOT) combines FmFLIM and Scanning laser optical tomography (SLOT) to perform multiplexed 3D FLIM imaging of live embryos. The system had demonstrate multiplexed functional imaging of zebrafish embryos genetically express Foster Resonant Energy Transfer (FRET) sensors. However, previous system has a 20 micron resolution because the focused Gaussian beam diverges quickly from the focused plane, makes it difficult to achieve high resolution imaging over a long projection depth. Here, we present a high-resolution FmFLIM-SLOT system with achromatic Bessel beam, which achieves 3 micron resolution in 3D deep tissue imaging. In Bessel-FmFLIM-SLOT, multiple laser excitation lines are firstly intensity modulated by a Michelson interferometer with a spinning polygon mirror optical delay line, which enables Fourier multiplexed multi-channel lifetime measurements. Then, a spatial light modulator and a prism are used to transform the modulated Gaussian laser beam to an achromatic Bessel beam. The achromatic Bessel beam scans across the whole specimen with equal angular intervals as sample rotated. After tomography reconstruction and the frequency domain lifetime analysis method, both the 3D intensity and lifetime image of multiple excitation-emission can be obtained. Using Bessel-FmFLIM-SLOT system, we performed cellular-resolution FLIM tomography imaging of live zebrafish embryo. Genetically expressed FRET sensors in these embryo will allow non-invasive observation of multiple biochemical processes in vivo.

  10. Development of a metallic magnetic calorimeter for high resolution spectroscopy

    International Nuclear Information System (INIS)

    Linck, M.

    2007-01-01

    In this thesis the development of a metallic magnetic calorimeter for high resolution detection of single x-ray quanta is described. The detector consists of an X-ray absorber and a paramagnetic temperature sensor. The raise in temperature of the paramagnetic sensor due to the absorption of a single X-ray is measured by the change in magnetization of the sensor using a low-noise SQUID magnetometer. The thermodynamic properties of the detector can be described by a theoretical model based on a mean field approximation. This allows for an optimization of the detector design with respect to signal size. The maximal archivable energy resolution is limited by thermodynamic energy fluctuations between absorber, heat bath and thermometer. An interesting field of application for a metallic magnetic calorimeter is X-ray astronomy and the investigation of X-ray emitting objects. Through high-resolution X-ray spectroscopy it is possible to obtain information about physical processes of even far distant objects. The magnetic calorimeter that was developed in this thesis has a metallic absorber with a quantum efficiency of 98% at 6 keV. The energy resolution of the magnetic calorimeter is EFWHM=2.7 eV at 5.9 keV. The deviation of the detector response from a linear behavior of the detector is only 0.8% at 5.9 keV. (orig.)

  11. Methylation-Sensitive High Resolution Melting (MS-HRM).

    Science.gov (United States)

    Hussmann, Dianna; Hansen, Lise Lotte

    2018-01-01

    Methylation-Sensitive High Resolution Melting (MS-HRM) is an in-tube, PCR-based method to detect methylation levels at specific loci of interest. A unique primer design facilitates a high sensitivity of the assays enabling detection of down to 0.1-1% methylated alleles in an unmethylated background.Primers for MS-HRM assays are designed to be complementary to the methylated allele, and a specific annealing temperature enables these primers to anneal both to the methylated and the unmethylated alleles thereby increasing the sensitivity of the assays. Bisulfite treatment of the DNA prior to performing MS-HRM ensures a different base composition between methylated and unmethylated DNA, which is used to separate the resulting amplicons by high resolution melting.The high sensitivity of MS-HRM has proven useful for detecting cancer biomarkers in a noninvasive manner in urine from bladder cancer patients, in stool from colorectal cancer patients, and in buccal mucosa from breast cancer patients. MS-HRM is a fast method to diagnose imprinted diseases and to clinically validate results from whole-epigenome studies. The ability to detect few copies of methylated DNA makes MS-HRM a key player in the quest for establishing links between environmental exposure, epigenetic changes, and disease.

  12. High resolution tsunami inversion for 2010 Chile earthquake

    Directory of Open Access Journals (Sweden)

    T.-R. Wu

    2011-12-01

    Full Text Available We investigate the feasibility of inverting high-resolution vertical seafloor displacement from tsunami waveforms. An inversion method named "SUTIM" (small unit tsunami inversion method is developed to meet this goal. In addition to utilizing the conventional least-square inversion, this paper also enhances the inversion resolution by Grid-Shifting method. A smooth constraint is adopted to gain stability. After a series of validation and performance tests, SUTIM is used to study the 2010 Chile earthquake. Based upon data quality and azimuthal distribution, we select tsunami waveforms from 6 GLOSS stations and 1 DART buoy record. In total, 157 sub-faults are utilized for the high-resolution inversion. The resolution reaches 10 sub-faults per wavelength. The result is compared with the distribution of the aftershocks and waveforms at each gauge location with very good agreement. The inversion result shows that the source profile features a non-uniform distribution of the seafloor displacement. The highly elevated vertical seafloor is mainly concentrated in two areas: one is located in the northern part of the epicentre, between 34° S and 36° S; the other is in the southern part, between 37° S and 38° S.

  13. Exogenous lipoid pneumonia: high-resolution CT findings

    International Nuclear Information System (INIS)

    Lee, J.S.; Song, K.S.; Lim, T.H.; Im, J.G.; Seo, J.B.

    1999-01-01

    The aim of this study was to assess high-resolution computed tomography (HRCT) findings of exogenous lipoid pneumonia. High-resolution computed tomography was obtained in 25 patients with proven exogenous lipoid pneumonia resulting from aspiration of squalene (derived from shark liver oil). Diagnosis was based on biopsy (n = 9), bronchoalveolar lavage (n = 8), or sputum cytology and clinical findings (n = 8). The clinical history of taking squalene was confirmed in all patients. The CT findings were classified into three patterns: diffuse ground-glass opacity, consolidation, and interstitial abnormalities. Distribution of the abnormalities, duration of taking squalene, predisposing factors for aspiration, and route of administration were analyzed. Ten patients showed diffuse ground-glass opacity pattern. Seven of 10 patients had predisposing conditions such as unconsciousness, pharyngeal dysmotility, or motor disturbances, and 6 patients had a recent history of taking large amount of squalene through nasal route. Seven patients who had consolidation pattern had a history of taking squalene for several months and did not have any predisposing factor. All of the 5 patients who had a pattern of interstitial abnormalities had a history of taking squalene longer than 1 year and showed segmental distribution of interstitial thickening with interposing ground-glass opacities. Three patients simultaneously had two different patterns at different lobes of the lung. The HRCT findings of lipoid pneumonia are ground-glass opacities, consolidation, and interstitial abnormalities. These HRCT findings with appropriate inquiries could be useful for diagnosis of exogeneous lipoid pneumonia. (orig.)

  14. Quantitative analysis of cholesteatoma using high resolution computed tomography

    International Nuclear Information System (INIS)

    Kikuchi, Shigeru; Yamasoba, Tatsuya; Iinuma, Toshitaka.

    1992-01-01

    Seventy-three cases of adult cholesteatoma, including 52 cases of pars flaccida type cholesteatoma and 21 of pars tensa type cholesteatoma, were examined using high resolution computed tomography, in both axial (lateral semicircular canal plane) and coronal sections (cochlear, vestibular and antral plane). These cases were classified into two subtypes according to the presence of extension of cholesteatoma into the antrum. Sixty cases of chronic otitis media with central perforation (COM) were also examined as controls. Various locations of the middle ear cavity were measured in terms of size in comparison with pars flaccida type cholesteatoma, pars tensa type cholesteatoma and COM. The width of the attic was significantly larger in both pars flaccida type and pars tensa type cholesteatoma than in COM. With pars flaccida type cholesteatoma there was a significantly larger distance between the malleus and lateral wall of the attic than with COM. In contrast, the distance between the malleus and medial wall of the attic was significantly larger with pars tensa type cholesteatoma than with COM. With cholesteatoma extending into the antrum, regardless of the type of cholesteatoma, there were significantly larger distances than with COM at the following sites: the width and height of the aditus ad antrum, and the width, height and anterior-posterior diameter of the antrum. However, these distances were not significantly different between cholesteatoma without extension into the antrum and COM. The hitherto demonstrated qualitative impressions of bone destruction in cholesteatoma were quantitatively verified in detail using high resolution computed tomography. (author)

  15. Characterization of ceramic archaeological by high resolution X ray microtomography

    International Nuclear Information System (INIS)

    Machado, Alessandra C.; Freitas, Renato; Calza, Cristiane F.; Lopes, Ricardo T.; Lima, Inaya; Carvalho, Daniele D.; Gaspar, Maria D.

    2013-01-01

    Characterization of ceramic fragments is a very important area of research in art and archeometry area because it enables a greater understanding of how ancient civilizations behave and what were their traditions and customs. Petrography and chemical analyses are commonly used, but these techniques are destructive, which is not interesting for this type of sample. Through the exchange of multidisciplinary scientific knowledge and new partnerships, high resolution X-ray microtomography has been introduced in archaeological area as a great possibility of 3D inspection in a non-destructive way. The goal of this work is to investigate the internal microstructures of four samples of archeological ceramic, from the Archaeological Site of Macacu - RJ. The X-ray microtomography were performed in a high resolution setup, and can be used to infer the nature of organic temper even with all plant remains completely burnt out during the firing process and also to ensure the homogeneity of samples envisaged for geochemical analyses, especially with respect to the distribution of chemically diverse fabric compounds. In this way this study intends to contribute to our understanding of the archaeological and historical formations of this region. (author)

  16. Characterization of ceramic archaeological by high resolution X ray microtomography

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Alessandra C.; Freitas, Renato; Calza, Cristiane F.; Lopes, Ricardo T.; Lima, Inaya, E-mail: alecastro@lin.ufrj.br [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentacao Nuclear; Carvalho, Daniele D.; Gaspar, Maria D. [Museu Nacional (MN/UFRJ), RJ (Brazil). Centro de Tecnologia

    2013-07-01

    Characterization of ceramic fragments is a very important area of research in art and archeometry area because it enables a greater understanding of how ancient civilizations behave and what were their traditions and customs. Petrography and chemical analyses are commonly used, but these techniques are destructive, which is not interesting for this type of sample. Through the exchange of multidisciplinary scientific knowledge and new partnerships, high resolution X-ray microtomography has been introduced in archaeological area as a great possibility of 3D inspection in a non-destructive way. The goal of this work is to investigate the internal microstructures of four samples of archeological ceramic, from the Archaeological Site of Macacu - RJ. The X-ray microtomography were performed in a high resolution setup, and can be used to infer the nature of organic temper even with all plant remains completely burnt out during the firing process and also to ensure the homogeneity of samples envisaged for geochemical analyses, especially with respect to the distribution of chemically diverse fabric compounds. In this way this study intends to contribute to our understanding of the archaeological and historical formations of this region. (author)

  17. MR-Venography Using High Resolution True-FISP

    Energy Technology Data Exchange (ETDEWEB)

    Spuentrup, E. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Beth Israel Deaconess Medical Center, Boston, MA (United States). Dept. of Medicine; Harvard Medical School, Boston, MA (United States); Buecker, A.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Stuber, M. [Beth Israel Deaconess Medical Center, Boston, MA (United States). Dept. of Medicine; Harvard Medical School, Boston, MA (United States); Philips Med. Syst., Best (Netherlands)

    2001-08-01

    A new fast MR-venography approach using a high resolution True-FISP imaging sequence was investigated in 20 patients suffering from 23 deep vein thromboses. Diagnosis was proven by X-ray venography, CT or ultrasound examination. The presented technique allowed for clear thrombus visualization with a high contrast to the surrounding blood pool even in calf veins. Acquisition time was less than 10 minutes for imaging the pelvis and the legs. No contrast media was needed. The presented high resolution True-FISP MR-veography is a promising non-invasive, fast MR-venography approach for detection of deep venous thrombosis. (orig.) [German] Eine neue schnelle, oertlich hochaufgeloeste MR-Phlebographietechnik mit einer axialen True-FISP Bildgebungssequenz wurde an 20 Patienten mit 23 nach-gewiesenen tiefen Beinvenenthrombosen untersucht. Die Befunde wurden mit einer konventionellen Roentgenphlebographie, einer CT oder einer Sonographie gesichert. Die vorgestellte Technik erlaubte in allen Faellen eine Thrombusdarstellung mit hohem Kontrast zum umgebenden venoesen Blut, wobei aufgrund der hohen Ortsaufloesung auch die Unterschenkelvenen beurteilt werden konnten. Die Datenaufnahmezeit zur Untersuchung des Beckens und der Beine betrug weniger als 10 Minuten. Kontrastmittel wurde nicht benoetigt. Die vorgestellte MR-Phlebographietechnik unter Verwendung einer oertlich hochauf-geloesten True-FISP Sequenz ist eine neue, vielversprechende, nicht-invasive Technik zur Diagnostik der tiefen Bein- und Beckenvenenthrombose. (orig.)

  18. High-resolution electron microscopy of advanced materials

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, T.E.; Kung, H.H.; Sickafus, K.E.; Gray, G.T. III; Field, R.D.; Smith, J.F. [Los Alamos National Lab., NM (United States). Materials Science and Technology Div.

    1997-11-01

    This final report chronicles a three-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The High-Resolution Electron Microscopy Facility has doubled in size and tripled in quality since the beginning of the three-year period. The facility now includes a field-emission scanning electron microscope, a 100 kV field-emission scanning transmission electron microscope (FE-STEM), a 300 kV field-emission high-resolution transmission electron microscope (FE-HRTEM), and a 300 kV analytical transmission electron microscope. A new orientation imaging microscope is being installed. X-ray energy dispersive spectrometers for chemical analysis are available on all four microscopes; parallel electron energy loss spectrometers are operational on the FE-STEM and FE-HRTEM. These systems enable evaluation of local atomic bonding, as well as chemical composition in nanometer-scale regions. The FE-HRTEM has a point-to-point resolution of 1.6 {angstrom}, but the resolution can be pushed to its information limit of 1 {angstrom} by computer reconstruction of a focal series of images. HRTEM has been used to image the atomic structure of defects such as dislocations, grain boundaries, and interfaces in a variety of materials from superconductors and ferroelectrics to structural ceramics and intermetallics.

  19. Pulmonary leukemic involvement: high-resolution computed tomography evaluation

    International Nuclear Information System (INIS)

    Oliveira, Ana Paola de; Marchiori, Edson; Souza Junior, Arthur Soares

    2004-01-01

    Objective: To evaluate the role of high-resolution computed tomography (HRCT) in patients with leukemia and pulmonary symptoms, to establish the main patterns and to correlate them with the etiology. Materials and Methods: This is a retrospective study of the HRCT of 15 patients with leukemia and pulmonary symptoms. The examinations were performed using a spatial high-resolution protocol and were analyzed by two independent radiologists. Results: The main HRCT patterns found were ground-glass opacity (n=11), consolidation (n=9), airspace nodules (n=3), septal thickening (n=3), tree-in-bud pattern (n=3), and pleural effusion (n=3). Pulmonary infection was the most common finding seen in 12 patients: bacterial pneumonia (n=6), fungal infection (n = 4), pulmonary tuberculosis (n=1) and viral infection (n=1). Leukemic pleural infiltration (n=1), lymphoma (n=1) and pulmonary hemorrhage (n=1) were detected in the other three patients. Conclusion: HRCT is an important tool that may suggest the cause of lung involvement, its extension and in some cases to guide invasive procedures in patients with leukemia. (author)

  20. Peculiar velocity effects in high-resolution microwave background experiments

    International Nuclear Information System (INIS)

    Challinor, Anthony; Leeuwen, Floor van

    2002-01-01

    We investigate the impact of peculiar velocity effects due to the motion of the solar system relative to the cosmic microwave background (CMB) on high resolution CMB experiments. It is well known that on the largest angular scales the combined effects of Doppler shifts and aberration are important; the lowest Legendre multipoles of total intensity receive power from the large CMB monopole in transforming from the CMB frame. On small angular scales aberration dominates and is shown here to lead to significant distortions of the total intensity and polarization multipoles in transforming from the rest frame of the CMB to the frame of the solar system. We provide convenient analytic results for the distortions as series expansions in the relative velocity of the two frames, but at the highest resolutions a numerical quadrature is required. Although many of the high resolution multipoles themselves are severely distorted by the frame transformations, we show that their statistical properties distort by only an insignificant amount. Therefore, the cosmological parameter estimation is insensitive to the transformation from the CMB frame (where theoretical predictions are calculated) to the rest frame of the experiment

  1. Image thresholding in the high resolution target movement monitor

    Science.gov (United States)

    Moss, Randy H.; Watkins, Steve E.; Jones, Tristan H.; Apel, Derek B.; Bairineni, Deepti

    2009-03-01

    Image thresholding in the High Resolution Target Movement Monitor (HRTMM) is examined. The HRTMM was developed at the Missouri University of Science and Technology to detect and measure wall movements in underground mines to help reduce fatality and injury rates. The system detects the movement of a target with sub-millimeter accuracy based on the images of one or more laser dots projected on the target and viewed by a high-resolution camera. The relative position of the centroid of the laser dot (determined by software using thresholding concepts) in the images is the key factor in detecting the target movement. Prior versions of the HRTMM set the image threshold based on a manual, visual examination of the images. This work systematically examines the effect of varying threshold on the calculated centroid position and describes an algorithm for determining a threshold setting. First, the thresholding effects on the centroid position are determined for a stationary target. Plots of the centroid positions as a function of varying thresholds are obtained to identify clusters of thresholds for which the centroid position does not change for stationary targets. Second, the target is moved away from the camera in sub-millimeter increments and several images are obtained at each position and analyzed as a function of centroid position, target movement and varying threshold values. With this approach, the HRTMM can accommodate images in batch mode without the need for manual intervention. The capability for the HRTMM to provide automated, continuous monitoring of wall movement is enhanced.

  2. A high resolution pneumatic stepping actuator for harsh reactor environments

    Science.gov (United States)

    Tippetts, Thomas B.; Evans, Paul S.; Riffle, George K.

    1993-01-01

    A reactivity control actuator for a high-power density nuclear propulsion reactor must be installed in close proximity to the reactor core. The energy input from radiation to the actuator structure could exceed hundreds of W/cc unless low-cross section, low-absorptivity materials are chosen. Also, for post-test handling and subsequent storage, materials should not be used that are activated into long half-life isotopes. Pneumatic actuators can be constructed from various reactor-compatible materials, but conventional pneumatic piston actuators generally lack the stiffness required for high resolution reactivity control unless electrical position sensors and compensated electronic control systems are used. To overcome these limitations, a pneumatic actuator is under development that positions an output shaft in response to a series of pneumatic pulses, comprising a pneumatic analog of an electrical stepping motor. The pneumatic pulses are generated remotely, beyond the strong radiation environment, and transmitted to the actuator through tubing. The mechanically simple actuator uses a nutating gear harmonic drive to convert motion of small pistons directly to high-resolution angular motion of the output shaft. The digital nature of this actuator is suitable for various reactor control algorithms but is especially compatible with the three bean salad algorithm discussed by Ball et al. (1991).

  3. Evaluation of a high resolution silicon PET insert module

    Energy Technology Data Exchange (ETDEWEB)

    Grkovski, Milan, E-mail: milan.grkovski@ijs.si [Jožef Stefan Institute, Ljubljana (Slovenia); Memorial Sloan Kettering Cancer Center, New York, NY (United States); Brzezinski, Karol [IFIC/CSIC, Valencia (Spain); Cindro, Vladimir [Jožef Stefan Institute, Ljubljana (Slovenia); Clinthorne, Neal H. [University of Michigan, Ann Arbor, MI (United States); Kagan, Harris [Ohio State University, Columbus, OH (United States); Lacasta, Carlos [IFIC/CSIC, Valencia (Spain); Mikuž, Marko [Jožef Stefan Institute, Ljubljana (Slovenia); Solaz, Carles [IFIC/CSIC, Valencia (Spain); Studen, Andrej [Jožef Stefan Institute, Ljubljana (Slovenia); Weilhammer, Peter [Ohio State University, Columbus, OH (United States); Žontar, Dejan [Jožef Stefan Institute, Ljubljana (Slovenia)

    2015-07-11

    Conventional PET systems can be augmented with additional detectors placed in close proximity of the region of interest. We developed a high resolution PET insert module to evaluate the added benefit of such a combination. The insert module consists of two back-to-back 1 mm thick silicon sensors, each segmented into 1040 1 mm{sup 2} pads arranged in a 40 by 26 array. A set of 16 VATAGP7.1 ASICs and a custom assembled data acquisition board were used to read out the signal from the insert module. Data were acquired in slice (2D) geometry with a Jaszczak phantom (rod diameters of 1.2–4.8 mm) filled with {sup 18}F-FDG and the images were reconstructed with ML-EM method. Both data with full and limited angular coverage from the insert module were considered and three types of coincidence events were combined. The ratio of high-resolution data that substantially improves quality of the reconstructed image for the region near the surface of the insert module was estimated to be about 4%. Results from our previous studies suggest that such ratio could be achieved at a moderate technological expense by using an equivalent of two insert modules (an effective sensor thickness of 4 mm)

  4. The development of high resolution silicon x-ray microcalorimeters

    Science.gov (United States)

    Porter, F. S.; Kelley, R. L.; Kilbourne, C. A.

    2005-12-01

    Recently we have produced x-ray microcalorimeters with resolving powers approaching 2000 at 5.9 keV using a spare XRS microcalorimeter array. We attached 400 um square, 8 um thick HgTe absorbers using a variety of attachment methods to an XRS array and ran the detector array at temperatures between 40 and 60 mK. The best results were for absorbers attached using the standard XRS absorber-pixel thermal isolation scheme utilizing SU8 polymer tubes. In this scenario we achieved a resolution of 3.2 eV FWHM at 5.9 keV. Substituting a silicon spacer for the SU8 tubes also yielded sub-4eV results. In contrast, absorbers attached directly to the thermistor produced significant position dependence and thus degraded resolution. Finally, we tested standard 640um-square XRS detectors at reduced bias power at 50mK and achieved a resolution of 3.7eV, a 50% improvement over the XRS flight instrument. Implanted silicon microcalorimeters are a mature flight-qualified technology that still has a substantial phase space for future development. We will discuss these new high resolution results, the various absorber attachment schemes, planned future improvements, and, finally, their relevance to future high resolution x-ray spectrometers including Constellation-X.

  5. High resolution muon computed tomography at neutrino beam facilities

    International Nuclear Information System (INIS)

    Suerfu, B.; Tully, C.G.

    2016-01-01

    X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pion decay pipe at a neutrino beam facility and what can be achieved for momentum resolution in a muon spectrometer. Such an imaging system can be applied in archaeology, art history, engineering, material identification and whenever there is a need to image inside a transportable object constructed of dense materials

  6. An original acquisition chain for the TOHR High Resolution Tomograph

    International Nuclear Information System (INIS)

    Pinot, Laurent

    1999-01-01

    The framework of this work is part of a new approach of emission tomography adapted to small animals. The principle of our tomographic system TOHR (French acronym for High Resolution Tomograph) is based on the use of large solid angle and high resolution focusing collimators each mounted in front of a detection module of high efficiency. With a first-generation acquisition chain we were able to characterize TOHR, however, to take fully advantage of the TOHR possibilities, a completely new acquisition scheme had to be designed. This system, being the main topic of this work, makes use of temporal information. The detection of a particle that entered the detector is translated into temporal logical signals. These signals pass into a time coding circuitry and the coded results are transferred in a digital processor. According to the initial terms of delivery, the developed acquisition chain steers the detection of events dependent on the deposited energy and time of arrival. The latter is done by coincidence measurements. All elements are mounted on a special board included into a PC unit and a dedicated program controls the whole system. First experiments showed up the interest of the new acquisition unit for other application in physics or medical imaging

  7. High resolution tsunami inversion for 2010 Chile earthquake

    Science.gov (United States)

    Wu, T.-R.; Ho, T.-C.

    2011-12-01

    We investigate the feasibility of inverting high-resolution vertical seafloor displacement from tsunami waveforms. An inversion method named "SUTIM" (small unit tsunami inversion method) is developed to meet this goal. In addition to utilizing the conventional least-square inversion, this paper also enhances the inversion resolution by Grid-Shifting method. A smooth constraint is adopted to gain stability. After a series of validation and performance tests, SUTIM is used to study the 2010 Chile earthquake. Based upon data quality and azimuthal distribution, we select tsunami waveforms from 6 GLOSS stations and 1 DART buoy record. In total, 157 sub-faults are utilized for the high-resolution inversion. The resolution reaches 10 sub-faults per wavelength. The result is compared with the distribution of the aftershocks and waveforms at each gauge location with very good agreement. The inversion result shows that the source profile features a non-uniform distribution of the seafloor displacement. The highly elevated vertical seafloor is mainly concentrated in two areas: one is located in the northern part of the epicentre, between 34° S and 36° S; the other is in the southern part, between 37° S and 38° S.

  8. High resolution and simultaneous monitoring of airborne radionuclides

    International Nuclear Information System (INIS)

    Abe, T.; Yamaguchi, Y.; Muguntha Manikandan, N.; Komura, K.

    2005-01-01

    By using 11 extremely low background Ge detectors at Ogoya Underground Laboratory, it became possible to investigate temporal variations of airborne 212 Pb (T 1/2 =10.6 h) along with 210 Pb and 7 Be with order of magnitude higher time resolution. Then, we have measured airborne nuclides at three monitoring points, (1) roof of our laboratory (LLRL; 40 m ASL), (2) Shinshiku Plateau (640 m ASL) located about 8 km from LLRL as a comparison of vertical distribution, and (3) Hegura Island (10 m ASL) at about 50 km from Wajima located north of Noto Peninsula facing on the Sea of Japan (about 180 km to the north-northeast of LLRL), to investigate influence of Asian continent. Airborne nuclides were collected by high volume air samplers at intervals of a few hours at either two or three points simultaneously. In the same manner, high resolution monitoring was carried out also at the time of passage of typhoon and cold front. In this study, we observed drastic temporal variations of airborne radionuclides and correlations of multiple monitoring points. The results indicate that high resolution and simultaneous monitoring is very useful to understand dynamic state of variations of airborne nuclides due to short and long-term air-mass movement. (author)

  9. High-Resolution Electronics: Spontaneous Patterning of High-Resolution Electronics via Parallel Vacuum Ultraviolet (Adv. Mater. 31/2016).

    Science.gov (United States)

    Liu, Xuying; Kanehara, Masayuki; Liu, Chuan; Sakamoto, Kenji; Yasuda, Takeshi; Takeya, Jun; Minari, Takeo

    2016-08-01

    On page 6568, T. Minari and co-workers describe spontaneous patterning based on the parallel vacuum ultraviolet (PVUV) technique, enabling the homogeneous integration of complex, high-resolution electronic circuits, even on large-scale, flexible, transparent substrates. Irradiation of PVUV to the hydrophobic polymer surface precisely renders the selected surface into highly wettable regions with sharply defined boundaries, which spontaneously guides a metal nanoparticle ink into a series of circuit lines and gaps with the widths down to a resolution of 1 μm. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Analysis of the gamma spectrometry {sup 210}Pb radioisotope in river bottom sediments of the hydrographic sub-basins around the UTM-Caldas

    Energy Technology Data Exchange (ETDEWEB)

    Dutra, Pedro H.; Carvalho Filho, Carlos A.; Moreira, Rubens M.; Menezes, Maria Angela B.C.; Oliveira, Aline F.G. de, E-mail: pedrohenrique.dutra@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Silva, Nivaldo C., E-mail: ncsilva@cnen.gov.br [Comissao Nacional de Energia Nuclear (LAPOC/CNEN-MG), Pocos de Caldas, MG (Brazil). Laboratorio de Pocos de Caldas; Viana, Valquiria F.L., E-mail: valquiria.flviana@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Instituto de Ciencias Biologicas

    2015-07-01

    The uranium mine of Caldas, currently named Ore Treatment Unit (UTM-Caldas), is sited at the Pocos de Caldas Plateau (Minas Gerais State) and was the first uranium mineral-industrial complex in Brazil. It has been installed since 1982 and now it is under decommissioning process. Taking into account the potential sources of contamination and the assessment of the impact of the mine, based on the presence of radionuclides from the radioactive decay series of natural {sup 238}U, the aim of the article is to present the distribution of {sup 210}Pb in the stream bottom sediments of the study area that consists of the Taquari watershed, sub-divided by its three major sub-basins: Consulta stream, Soberbo stream and Taquari river. The radionuclide activity concentrations were measured in sediment samples that were collected in twelve collecting points, during four sampling campaigns, carried out in the dry and rainy seasons of 2010 and 2011. The results of the {sup 210}Pb concentration activity were obtained by gamma spectrometry performed in both high and low energy CANBERRA detectors. The results point out that the UTM-Caldas is influencing on the bottom sediment distribution of {sup 210}Pb activity in its neighborhood. However, a more detailed study should be done in order to identify if there is another source of {sup 210}Pb in the study area, such as a geogenic anomaly, that may contributing to the local increment of {sup 210}Pb activity. (author)

  11. Measurement of radon concentration in water by means of {alpha}, {gamma} spectrometry. Radon concentration in ground and spring water in Hiroshima Prefecture

    Energy Technology Data Exchange (ETDEWEB)

    Shizuma, Kiyoshi [Hiroshima Univ. (Japan)

    1997-02-01

    Radon ({sup 222}Rn, T{sub 1/2}=3.8235{+-}0.0003d) is {alpha}-ray releasing nuclide, so that it can not be detected by {gamma}-ray measurement. But, the daughter nuclides {sup 214}Pb (T{sub 1/2}=26.8 min) and {sup 214}Bi (T{sub 1/2}=19.9 min) release {gamma}-ray, accordingly they are measured by Ge detector. Their radioactive equilibrium is kept in the closed vessel, because their half-lives are shorter than that of radon. We developed a measurement method of radon concentration by means of {gamma}-spectrometry. We applied this method to catch radon in the atmosphere by active carbon. The same principle can be applied to radon in water. Radon concentrations in the ground water were measured in 22 points in the Higashi-Hiroshima city and 82 points in the Hiroshima prefecture. The efficiencies of {gamma}-ray were determined. The radon concentration showed between 11 and 459 Bq/l and the average was 123 Bq/l. The high concentration of radon was distributed in the spring of granitic layer and higher concentration of radon were observed in the ground water of fault. (S.Y.)

  12. Analysis of the gamma spectrometry 210Pb radioisotope in river bottom sediments of the hydrographic sub-basins around the UTM-Caldas

    International Nuclear Information System (INIS)

    Dutra, Pedro H.; Carvalho Filho, Carlos A.; Moreira, Rubens M.; Menezes, Maria Angela B.C.; Oliveira, Aline F.G. de; Silva, Nivaldo C.; Viana, Valquiria F.L.

    2015-01-01

    The uranium mine of Caldas, currently named Ore Treatment Unit (UTM-Caldas), is sited at the Pocos de Caldas Plateau (Minas Gerais State) and was the first uranium mineral-industrial complex in Brazil. It has been installed since 1982 and now it is under decommissioning process. Taking into account the potential sources of contamination and the assessment of the impact of the mine, based on the presence of radionuclides from the radioactive decay series of natural 238 U, the aim of the article is to present the distribution of 210 Pb in the stream bottom sediments of the study area that consists of the Taquari watershed, sub-divided by its three major sub-basins: Consulta stream, Soberbo stream and Taquari river. The radionuclide activity concentrations were measured in sediment samples that were collected in twelve collecting points, during four sampling campaigns, carried out in the dry and rainy seasons of 2010 and 2011. The results of the 210 Pb concentration activity were obtained by gamma spectrometry performed in both high and low energy CANBERRA detectors. The results point out that the UTM-Caldas is influencing on the bottom sediment distribution of 210 Pb activity in its neighborhood. However, a more detailed study should be done in order to identify if there is another source of 210 Pb in the study area, such as a geogenic anomaly, that may contributing to the local increment of 210 Pb activity. (author)

  13. Determination of radium isotopes in environmental samples by gamma spectrometry, liquid scintillation counting and alpha spectrometry: a review of analytical methodology

    International Nuclear Information System (INIS)

    Jia, Guogang; Jia, Jing

    2012-01-01

    Radium (Ra) isotopes are important from the viewpoints of radiation protection and environmental protection. Their high toxicity has stimulated the continuing interest in methodology research for determination of Ra isotopes in various media. In this paper, the three most routinely used analytical techniques for Ra isotope determination in biological and environmental samples, i.e. low-background γ-spectrometry, liquid scintillation counting and α-spectrometry, were reviewed, with emphasis on new methodological developments in sample preparation, preconcentration, separation, purification, source preparation and measurement techniques. The accuracy, selectivity, traceability, applicability and minimum detectable activity (MDA) of the three techniques were discussed. It was concluded that the MDA (0.1 mBq L −1 ) of the α-spectrometry technique coupled with chemical separation is about two orders of magnitude lower than that of low-background HPGe γ-spectrometry and LSC techniques. Therefore, when maximum sensitivity is required, the α-spectrometry technique remains the first choice. - Highlights: ► A review is made for determination of Ra isotopes in environmental samples. ► Gamma spectrometry, LSC and a-spectrometry are the main concerned radiometric approach. ► Sample preparation, preconcentration, separation and source preparation are discussed. ► The methods can analyse air, water, seawater, soil, sediment and foodstuffs samples. ► Some new data obtained recently from our laboratory for Ra method study are included.

  14. High resolution modelling of extreme precipitation events in urban areas

    Science.gov (United States)

    Siemerink, Martijn; Volp, Nicolette; Schuurmans, Wytze; Deckers, Dave

    2015-04-01

    The present day society needs to adjust to the effects of climate change. More extreme weather conditions are expected, which can lead to longer periods of drought, but also to more extreme precipitation events. Urban water systems are not designed for such extreme events. Most sewer systems are not able to drain the excessive storm water, causing urban flooding. This leads to high economic damage. In order to take appropriate measures against extreme urban storms, detailed knowledge about the behaviour of the urban water system above and below the streets is required. To investigate the behaviour of urban water systems during extreme precipitation events new assessment tools are necessary. These tools should provide a detailed and integral description of the flow in the full domain of overland runoff, sewer flow, surface water flow and groundwater flow. We developed a new assessment tool, called 3Di, which provides detailed insight in the urban water system. This tool is based on a new numerical methodology that can accurately deal with the interaction between overland runoff, sewer flow and surface water flow. A one-dimensional model for the sewer system and open channel flow is fully coupled to a two-dimensional depth-averaged model that simulates the overland flow. The tool uses a subgrid-based approach in order to take high resolution information of the sewer system and of the terrain into account [1, 2]. The combination of using the high resolution information and the subgrid based approach results in an accurate and efficient modelling tool. It is now possible to simulate entire urban water systems using extreme high resolution (0.5m x 0.5m) terrain data in combination with a detailed sewer and surface water network representation. The new tool has been tested in several Dutch cities, such as Rotterdam, Amsterdam and The Hague. We will present the results of an extreme precipitation event in the city of Schiedam (The Netherlands). This city deals with

  15. High resolution remote sensing of water surface patterns

    Science.gov (United States)

    Woodget, A.; Visser, F.; Maddock, I.; Carbonneau, P.

    2012-12-01

    The assessment of in-stream habitat availability within fluvial environments in the UK traditionally includes the mapping of patterns which appear on the surface of the water, known as 'surface flow types' (SFTs). The UK's River Habitat Survey identifies ten key SFTs, including categories such as rippled flow, upwelling, broken standing waves and smooth flow. SFTs result from the interaction between the underlying channel morphology, water depth and velocity and reflect the local flow hydraulics. It has been shown that SFTs can be both biologically and hydraulically distinct. SFT mapping is usually conducted from the river banks where estimates of spatial coverage are made by eye. This approach is affected by user subjectivity and inaccuracies in the spatial extent of mapped units. Remote sensing and specifically the recent developments in unmanned aerial systems (UAS) may now offer an alternative approach for SFT mapping, with the capability for rapid and repeatable collection of very high resolution imagery from low altitudes, under bespoke flight conditions. This PhD research is aimed at investigating the mapping of SFTs using high resolution optical imagery (less than 10cm) collected from a helicopter-based UAS flown at low altitudes (less than 100m). This paper presents the initial findings from a series of structured experiments on the River Arrow, a small lowland river in Warwickshire, UK. These experiments investigate the potential for mapping SFTs from still and video imagery of different spatial resolutions collected at different flying altitudes and from different viewing angles (i.e. vertical and oblique). Imagery is processed using 3D mosaicking software to create orthophotos and digital elevation models (DEM). The types of image analysis which are tested include a simple, manual visual assessment undertaken in a GIS environment, based on the high resolution optical imagery. In addition, an object-based image analysis approach which makes use of the

  16. A PICTORIAL PRESENTATION OF ESOPHAGEAL HIGH RESOLUTION MANOMETRY CURRENT PARAMETERS.

    Science.gov (United States)

    Lafraia, Fernanda M; Herbella, Fernando A M; Kalluf, Julia R; Patti, Marco G

    2017-01-01

    High resolution manometry is the current technology used to the study of esophageal motility and is replacing conventional manometry in important centers for esophageal motility with parameters used on esophageal motility, following the Chicago Classification. This classification unifies high resolution manometry interpretation and classifies esophageal disorders. This review shows, in a pictorial presentation, the new parameters established by the Chicago Classification, version 3.0, aimed to allow an easy comprehension and interpretation of high resolution manometry. Esophageal manometries performed by the authors were reviewed to select illustrative tracings representing Chicago Classification parameters. The parameters are: Esophagogastric Morphology, that classifies this junction according to its physiology and anatomy; Integrated Relaxation Pressure, that measures the lower esophageal sphincter relaxation; Distal Contractile Integral, that evaluates the contraction vigor of each wave; and, Distal Latency, that measures the peristalsis velocity from the beginning of the swallow to the epiphrenic ampulla. Clinical applications of these new concepts is still under evaluation. Mostrar, de forma pictórica, os novos parâmetros compilados na versão 3.0 da Classificação de Chicago, buscando facilitar a compreensão e interpretação da manometria de alta resolução. Foram revistas as manometrias da casuística dos autores e selecionados os traçados representativos dos parâmetros da Classificação de Chicago. Entre os parâmetros apresentados foram considerados a Morfologia da Transição Gastroesofágica, que classifica o segmento de acordo com sua fisiologia e anatomia; a Integral da Pressão de Relaxamento, que mede o relaxamento do esfíncter esofagiano inferior; a Integral Contrátil Distal, que avalia o vigor contrátil da onda peristáltica; e, a Latência Distal, que mede o tempo da peristalse, desde o início da deglutição até a ampola epifr

  17. Quantifying and containing the curse of high resolution coronal imaging

    Directory of Open Access Journals (Sweden)

    V. Delouille

    2008-10-01

    Full Text Available Future missions such as Solar Orbiter (SO, InterHelioprobe, or Solar Probe aim at approaching the Sun closer than ever before, with on board some high resolution imagers (HRI having a subsecond cadence and a pixel area of about (80 km2 at the Sun during perihelion. In order to guarantee their scientific success, it is necessary to evaluate if the photon counts available at these resolution and cadence will provide a sufficient signal-to-noise ratio (SNR. For example, if the inhomogeneities in the Quiet Sun emission prevail at higher resolution, one may hope to locally have more photon counts than in the case of a uniform source. It is relevant to quantify how inhomogeneous the quiet corona will be for a pixel pitch that is about 20 times smaller than in the case of SoHO/EIT, and 5 times smaller than TRACE. We perform a first step in this direction by analyzing and characterizing the spatial intermittency of Quiet Sun images thanks to a multifractal analysis. We identify the parameters that specify the scale-invariance behavior. This identification allows next to select a family of multifractal processes, namely the Compound Poisson Cascades, that can synthesize artificial images having some of the scale-invariance properties observed on the recorded images. The prevalence of self-similarity in Quiet Sun coronal images makes it relevant to study the ratio between the SNR present at SoHO/EIT images and in coarsened images. SoHO/EIT images thus play the role of "high resolution" images, whereas the "low-resolution" coarsened images are rebinned so as to simulate a smaller angular resolution and/or a larger distance to the Sun. For a fixed difference in angular resolution and in Spacecraft-Sun distance, we determine the proportion of pixels having a SNR preserved at high resolution given a particular increase in effective area. If scale-invariance continues to prevail at smaller scales, the conclusion reached with SoHO/EIT images can be transposed

  18. A high-resolution Fourier Transform Spectrometer for planetary spectroscopy

    Science.gov (United States)

    Cruikshank, D. P.; Sinton, W. M.

    1973-01-01

    The employment of a high-resolution Fourier Transform Spectrometer (FTS) is described for planetary and other astronomical spectroscopy in conjunction with the 88-inch telescope at Mauna Kea Observatory. The FTS system is designed for a broad range of uses, including double-beam laboratory spectroscopy, infrared gas chromatography, and nuclear magnetic resonance spectroscopy. The data system is well-suited to astronomical applications because of its great speed in acquiring and transforming data, and because of the enormous storage capability of the magnetic tape unit supplied with the system. The basic instrument is outlined 2nd some of the initial results from the first attempted use on the Mauna Kea 88-inch telescope are reported.

  19. High Resolution Energetic X-ray Imager (HREXI)

    Science.gov (United States)

    Grindlay, Jonathan

    We propose to design and build the first imaging hard X-ray detector system that incorporates 3D stacking of closely packed detector readouts in finely-spaced imaging arrays with their required data processing and control electronics. In virtually all imaging astronomical detectors, detector readout is done with flex connectors or connections that are not vertical but rather horizontal , requiring loss of focal plane area. For high resolution pixel detectors needed for high speed event-based X-ray imaging, from low energy applications (CMOS) with focusing X-ray telescopes, to hard X-ray applications with pixelated CZT for large area coded aperture telescopes, this new detector development offers great promise. We propose to extend our previous and current APRA supported ProtoEXIST program that has developed the first large area imaging CZT detectors and demonstrated their astrophysical capabilities on two successful balloon flight to a next generation High Resolution Energetic X-ray Imager (HREXI), which would incorporate microvia technology for the first time to connect the readout ASIC on each CZT crystal directly to its control and data processing system. This 3-dimensional stacking of detector and readout/control system means that large area (>2m2) imaging detector planes for a High Resolution Wide-field hard X-ray telescope can be built with initially greatly reduced detector gaps and ultimately with no gaps. This increases detector area, efficiency, and simplicity of detector integration. Thus higher sensitivity wide-field imagers will be possible at lower cost. HREXI will enable a post-Swift NASA mission such as the EREXS concept proposed to PCOS to be conducted as a future MIDEX mission. This mission would conduct a high resolution (<2 arcmin) , broad band (5 200 keV) hard X-ray survey of black holes on all scales with ~10X higher sensitivity than Swift. In the current era of Time Domain Astrophysics, such a survey capability, in conjunction with a n

  20. Unattented mode monitoring of high resolution gamma-ray spectra

    International Nuclear Information System (INIS)

    Smith, B.G.R.; Van Dyck, P.; Debraix, P.

    1991-01-01

    An Isotope Monitoring System (IMS) for unattended spectrum acquisition is described. This consists of a simple low cost flexible software package running on a Compaq 80386 and controlling up to 4 Canberra Packard System 100 multi-channel analyzer (MCA) cards. The IMS permits the independent configuration of each of the 4 MCA cards for different monitoring cycles and for different spectrum acquisition cycles each being based upon different trigger criteria. In this way IMS is able to automatically identify events, time tag them, and acquire and store valid spectra corresponding to those event. An additional feature of IMS permits to run a Multigroup Analysis (MGA) software package for the determination of plutonium isotopic compositions in batch mode. One particular application is discussed which consists of 4 high resolution gamma-ray detector systems connected together to the IMS for unattended spectrum acquisition. The off-line batch mode analysis of the spectra using MGA is also discussed

  1. High-resolution method for evolving complex interface networks

    Science.gov (United States)

    Pan, Shucheng; Hu, Xiangyu Y.; Adams, Nikolaus A.

    2018-04-01

    In this paper we describe a high-resolution transport formulation of the regional level-set approach for an improved prediction of the evolution of complex interface networks. The novelty of this method is twofold: (i) construction of local level sets and reconstruction of a global level set, (ii) local transport of the interface network by employing high-order spatial discretization schemes for improved representation of complex topologies. Various numerical test cases of multi-region flow problems, including triple-point advection, single vortex flow, mean curvature flow, normal driven flow, dry foam dynamics and shock-bubble interaction show that the method is accurate and suitable for a wide range of complex interface-network evolutions. Its overall computational cost is comparable to the Semi-Lagrangian regional level-set method while the prediction accuracy is significantly improved. The approach thus offers a viable alternative to previous interface-network level-set method.

  2. High resolution ultrasound and photoacoustic imaging of single cells

    Directory of Open Access Journals (Sweden)

    Eric M. Strohm

    2016-03-01

    Full Text Available High resolution ultrasound and photoacoustic images of stained neutrophils, lymphocytes and monocytes from a blood smear were acquired using a combined acoustic/photoacoustic microscope. Photoacoustic images were created using a pulsed 532 nm laser that was coupled to a single mode fiber to produce output wavelengths from 532 nm to 620 nm via stimulated Raman scattering. The excitation wavelength was selected using optical filters and focused onto the sample using a 20× objective. A 1000 MHz transducer was co-aligned with the laser spot and used for ultrasound and photoacoustic images, enabling micrometer resolution with both modalities. The different cell types could be easily identified due to variations in contrast within the acoustic and photoacoustic images. This technique provides a new way of probing leukocyte structure with potential applications towards detecting cellular abnormalities and diseased cells at the single cell level.

  3. HIGH-RESOLUTION ATMOSPHERIC ENSEMBLE MODELING AT SRNL

    Energy Technology Data Exchange (ETDEWEB)

    Buckley, R.; Werth, D.; Chiswell, S.; Etherton, B.

    2011-05-10

    The High-Resolution Mid-Atlantic Forecasting Ensemble (HME) is a federated effort to improve operational forecasts related to precipitation, convection and boundary layer evolution, and fire weather utilizing data and computing resources from a diverse group of cooperating institutions in order to create a mesoscale ensemble from independent members. Collaborating organizations involved in the project include universities, National Weather Service offices, and national laboratories, including the Savannah River National Laboratory (SRNL). The ensemble system is produced from an overlapping numerical weather prediction model domain and parameter subsets provided by each contributing member. The coordination, synthesis, and dissemination of the ensemble information are performed by the Renaissance Computing Institute (RENCI) at the University of North Carolina-Chapel Hill. This paper discusses background related to the HME effort, SRNL participation, and example results available from the RENCI website.

  4. Precision Viticulture from Multitemporal, Multispectral Very High Resolution Satellite Data

    Science.gov (United States)

    Kandylakis, Z.; Karantzalos, K.

    2016-06-01

    In order to exploit efficiently very high resolution satellite multispectral data for precision agriculture applications, validated methodologies should be established which link the observed reflectance spectra with certain crop/plant/fruit biophysical and biochemical quality parameters. To this end, based on concurrent satellite and field campaigns during the veraison period, satellite and in-situ data were collected, along with several grape samples, at specific locations during the harvesting period. These data were collected for a period of three years in two viticultural areas in Northern Greece. After the required data pre-processing, canopy reflectance observations, through the combination of several vegetation indices were correlated with the quantitative results from the grape/must analysis of grape sampling. Results appear quite promising, indicating that certain key quality parameters (like brix levels, total phenolic content, brix to total acidity, anthocyanin levels) which describe the oenological potential, phenolic composition and chromatic characteristics can be efficiently estimated from the satellite data.

  5. High-Resolution Characterization of UMo Alloy Microstructure

    Energy Technology Data Exchange (ETDEWEB)

    Devaraj, Arun [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kovarik, Libor [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Joshi, Vineet V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jana, Saumyadeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Manandhar, Sandeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Arey, Bruce W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-30

    This report highlights the capabilities and procedure for high-resolution characterization of UMo fuels in PNNL. Uranium-molybdenum (UMo) fuel processing steps, from casting to forming final fuel, directly affect the microstructure of the fuel, which in turn dictates the in-reactor performance of the fuel under irradiation. In order to understand the influence of processing on UMo microstructure, microstructure characterization techniques are necessary. Higher-resolution characterization techniques like transmission electron microscopy (TEM) and atom probe tomography (APT) are needed to interrogate the details of the microstructure. The findings from TEM and APT are also directly beneficial for developing predictive multiscale modeling tools that can predict the microstructure as a function of process parameters. This report provides background on focused-ion-beam–based TEM and APT sample preparation, TEM and APT analysis procedures, and the unique information achievable through such advanced characterization capabilities for UMo fuels, from a fuel fabrication capability viewpoint.

  6. THE HIGH-RESOLUTION INFRARED SPECTRUM OF HCl{sup +}

    Energy Technology Data Exchange (ETDEWEB)

    Doménech, J. L.; Herrero, V. J.; Tanarro, I. [Molecular Physics Department, Instituto de Estructura de la Materia (IEM-CSIC), Serrano 123, E-28006 Madrid (Spain); Drouin, B. J. [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109-8099 (United States); Cernicharo, J., E-mail: jl.domenech@csic.es [Molecular Astrophysics Group, Instituto de Ciencia de Materiales de Madrid (ICMM-CSIC), Sor Juana Inés de la Cruz 3, Cantoblanco, E-28049 Madrid (Spain)

    2016-12-20

    The chloroniumyl cation, HCl{sup +}, has been recently identified in space from Herschel 's spectra. A joint analysis of extensive vis-UV spectroscopy emission data together with a few high-resolution and high-accuracy millimeter-wave data provided the necessary rest frequencies to support the astronomical identification. Nevertheless, the analysis did not include any infrared (IR) vibration–rotation data. Furthermore, with the end of the Herschel mission, IR observations from the ground may be one of the few available means to further study this ion in space. In this work, we provide a set of accurate rovibrational transition wavenumbers, as well as a new and improved global fit of vis-UV, IR, and millimeter-wave spectroscopy laboratory data, that will aid in future studies of this molecule.

  7. Measuring large-scale social networks with high resolution.

    Directory of Open Access Journals (Sweden)

    Arkadiusz Stopczynski

    Full Text Available This paper describes the deployment of a large-scale study designed to measure human interactions across a variety of communication channels, with high temporal resolution and spanning multiple years-the Copenhagen Networks Study. Specifically, we collect data on face-to-face interactions, telecommunication, social networks, location, and background information (personality, demographics, health, politics for a densely connected population of 1000 individuals, using state-of-the-art smartphones as social sensors. Here we provide an overview of the related work and describe the motivation and research agenda driving the study. Additionally, the paper details the data-types measured, and the technical infrastructure in terms of both backend and phone software, as well as an outline of the deployment procedures. We document the participant privacy procedures and their underlying principles. The paper is concluded with early results from data analysis, illustrating the importance of multi-channel high-resolution approach to data collection.

  8. Application of the Oslo method to high resolution gamma spectra

    Science.gov (United States)

    Simon, A.; Guttormsen, M.; Larsen, A. C.; Beausang, C. W.; Humby, P.

    2015-10-01

    Hauser-Feshbach statistical model is a widely used tool for calculation of the reaction cross section, in particular for astrophysical processes. The HF model requires as an input an optical potential, gamma-strength function (GSF) and level density (LD) to properly model the statistical properties of the nucleus. The Oslo method is a well established technique to extract GSFs and LDs from experimental data, typically used for gamma-spectra obtained with scintillation detectors. Here, the first application of the Oslo method to high-resolution data obtained using the Ge detectors of the STARLITER setup at TAMU is discussed. The GSFs and LDs extracted from (p,d) and (p,t) reactions on 152154 ,Sm targets will be presented.

  9. Highly sensitive high resolution Raman spectroscopy using resonant ionization methods

    International Nuclear Information System (INIS)

    Owyoung, A.; Esherick, P.

    1984-05-01

    In recent years, the introduction of stimulated Raman methods has offered orders of magnitude improvement in spectral resolving power for gas phase Raman studies. Nevertheless, the inherent weakness of the Raman process suggests the need for significantly more sensitive techniques in Raman spectroscopy. In this we describe a new approach to this problem. Our new technique, which we call ionization-detected stimulated Raman spectroscopy (IDSRS), combines high-resolution SRS with highly-sensitive resonant laser ionization to achieve an increase in sensitivity of over three orders of magnitude. The excitation/detection process involves three sequential steps: (1) population of a vibrationally excited state via stimulated Raman pumping; (2) selective ionization of the vibrationally excited molecule with a tunable uv source; and (3) collection of the ionized species at biased electrodes where they are detected as current in an external circuit

  10. High resolution computed tomography of the middle ear

    International Nuclear Information System (INIS)

    Ikeda, Katsuhisa; Sakurai, Tokio; Saijo, Shigeru; Kobayashi, Toshimitsu

    1983-01-01

    High resolution computed tomography was performed in 57 cases with various middle ear diseases (chronic otitis media, otitis media with effusion, acute otitis media and atelectasis). Although further improvement in detectability is necessary in order to discriminate each type of the soft tissue lesions, CT is the most useful method currently available in detecting the small structures and soft tissue lesions of the middle ear. In particular, the lesions at the tympanic isthmus and tympanic fold could very clearly be detected only by CT. In acute otitis media, lesions usually started in the attic and spread to the mastoid air cells. In otitis media with effusion, the soft tissue shadow was ovserved in the attic and mastoid air cell. CT is valuable in diagnosis, evaluation of the treatment and prognosis, and analysis of pathophysiology in the middle ear diseases. (author)

  11. High resolution X-ray tomography for stationary multiphase flows

    International Nuclear Information System (INIS)

    Schmitz, D.; Reinecke, N.; Petritsch, G.; Mewes, D.

    1998-01-01

    The high resolution which can be obtained by computer assisted tomography is used to investigate the liquid distribution and void fraction in random and structured packing. With a spatial resolution of 0.4x0.4mm 2 it is possible even to detect thin liquid films on structured packings. The experimental set-up consists of a custom-built second generation tomograph. The imaged object consists of a column filled with either a random ceramic packing of spheres or a structured metal packing. The liquid and void fraction distribution in random and structured packings with a quiescent gaseous phase is visualized. The water/air system is used. The liquid distributor consists of a perforated plate. The experimental hold-up values averaged over the column cross-section are in good agreement with empirical equations. (author)

  12. Fast iterative segmentation of high resolution medical images

    International Nuclear Information System (INIS)

    Hebert, T.J.

    1996-01-01

    Various applications in positron emission tomography (PET), single photon emission computed tomography (SPECT) and magnetic resonance imaging (MRI) require segmentation of 20 to 60 high resolution images of size 256x256 pixels in 3-9 seconds per image. This places particular constraints on the design of image segmentation algorithms. This paper examines the trade-offs in segmenting images based on fitting a density function to the pixel intensities using curve-fitting versus the maximum likelihood method. A quantized data representation is proposed and the EM algorithm for fitting a finite mixture density function to the quantized representation for an image is derived. A Monte Carlo evaluation of mean estimation error and classification error showed that the resulting quantized EM algorithm dramatically reduces the required computation time without loss of accuracy

  13. High resolution capacitance detection circuit for rotor micro-gyroscope

    Directory of Open Access Journals (Sweden)

    Ming-Yuan Ren

    2014-03-01

    Full Text Available Conventional methods for rotor position detection of micro-gyroscopes include common exciting electrodes (single frequency and common sensing electrodes (frequency multiplex, but they have encountered some problems. So we present a high resolution and low noise pick-off circuit for micro-gyroscopes which utilizes the time multiplex method. The detecting circuit adopts a continuous-time current sensing circuit for capacitance measurement, and its noise analysis of the charge amplifier is introduced. The equivalent output noise power spectral density of phase-sensitive demodulation is 120 nV/Hz1/2. Tests revealed that the whole circuitry has a relative capacitance resolution of 1 × 10−8.

  14. Automated high-resolution NMR with a sample changer

    International Nuclear Information System (INIS)

    Wade, C.G.; Johnson, R.D.; Philson, S.B.; Strouse, J.; McEnroe, F.J.

    1989-01-01

    Within the past two years, it has become possible to obtain high-resolution NMR spectra using automated commercial instrumentation. Software control of all spectrometer functions has reduced most of the tedious manual operations to typing a few computer commands or even making selections from a menu. Addition of an automatic sample changer is the next natural step in improving efficiency and sample throughput; it has a significant (and even unexpected) impact on how NMR laboratories are run and how it is taught. Such an instrument makes even sophisticated experiments routine, so that people with no previous exposure to NMR can run these experiments after a training session of an hour or less. This A/C Interface examines the impact of such instrumentation on both the academic and the industrial laboratory

  15. DETECTION OF BARCHAN DUNES IN HIGH RESOLUTION SATELLITE IMAGES

    Directory of Open Access Journals (Sweden)

    M. A. Azzaoui

    2016-06-01

    Full Text Available Barchan dunes are the fastest moving sand dunes in the desert. We developed a process to detect barchans dunes on High resolution satellite images. It consisted of three steps, we first enhanced the image using histogram equalization and noise reduction filters. Then, the second step proceeds to eliminate the parts of the image having a texture different from that of the barchans dunes. Using supervised learning, we tested a coarse to fine textural analysis based on Kolomogorov Smirnov test and Youden’s J-statistic on co-occurrence matrix. As an output we obtained a mask that we used in the next step to reduce the search area. In the third step we used a gliding window on the mask and check SURF features with SVM to get barchans dunes candidates. Detected barchans dunes were considered as the fusion of overlapping candidates. The results of this approach were very satisfying in processing time and precision.

  16. High resolution computed tomography of the post partum pituitary gland

    International Nuclear Information System (INIS)

    Hinshaw, D.B.; Hasso, A.N.; Thompson, J.R.; Davidson, B.J.

    1984-01-01

    Eight volunteer post partum female patients were examined with high resolution computed tomography during the week immediately after delivery. All patients received high dose (40-70 gm) intravenous iodine contrast administration. The scans were examined for pituitary gland height, shape and homogeneity. All of the patients had enlarged glands by the traditional standards (i.e. gland height of 8 mm or greater). The diaphragma sellae in every call bulged upward with a convex domed appearance. The glands were generally inhomogeneous. One gland had a 4 mm focal well defined area of decreased attenuation. Two patients who were studied again months later had glands which had returned to ''normal'' size. The enlarged, upwardly convex pituitary gland appears to be typical and normal for the recently post partum period. (orig.)

  17. High-resolution sonography in carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Solbiati, L.; De Pra, L.; Rizzatto, G.; Derchi, L.E.

    1986-01-01

    Carpal tunnel syndrome, caused by the compression on the median nerve under the transverse carpal ligament, has multiple causes and clinical presentations. One hundred eighteen patients with carpal tunnel sydrome underwent high-resolution US which demonstrated unpalpable cystic masses in 25 patients (lobulated stalked synovial cysts in 19 and retrotendinous cysts in six, all confirmed at surgery), and diffuse thickening and decreased echogenicity of the tendon sheaths in 87 patients, suggesting tenosynovitis (confirmed at surgery in 64). In six patients simple encasement of muscle bellies in the carpal tunnel was shown. US can delineate the cause of carpal tunnel syndrome, suggest the need for surgery, and aid the surgeon in locating the lesion to be removed

  18. Feasibility tests of a high resolution sampling radial drift chamber

    International Nuclear Information System (INIS)

    Huth, J.

    1985-01-01

    The design concept and results of feasibility tests for a vertex detector intended for use in the TPC-PEP4/9 experiment are presented. The detector is based on a slow radial drift in dimethyl ether. High resolution localization of the avalanches at the sense wire is accomplished with nearby pickup wires and the utilization of waveform sampling electronics. The avalanche angular coordinate measurements, combined with knowledge of the electric field distribution and drift velocity permit reconstruction of the trajectory using essentially all track information. Measurements with a test chamber constructed to study characteristics of avalanche localization indicate that the recoverable track information in one centimeter of dimethyl ether at 1.5 atm is equivalent to 30 measurements of 40 μm accuracy. (orig.)

  19. Sparse Representation Denoising for Radar High Resolution Range Profiling

    Directory of Open Access Journals (Sweden)

    Min Li

    2014-01-01

    Full Text Available Radar high resolution range profile has attracted considerable attention in radar automatic target recognition. In practice, radar return is usually contaminated by noise, which results in profile distortion and recognition performance degradation. To deal with this problem, in this paper, a novel denoising method based on sparse representation is proposed to remove the Gaussian white additive noise. The return is sparsely described in the Fourier redundant dictionary and the denoising problem is described as a sparse representation model. Noise level of the return, which is crucial to the denoising performance but often unknown, is estimated by performing subspace method on the sliding subsequence correlation matrix. Sliding window process enables noise level estimation using only one observation sequence, not only guaranteeing estimation efficiency but also avoiding the influence of profile time-shift sensitivity. Experimental results show that the proposed method can effectively improve the signal-to-noise ratio of the return, leading to a high-quality profile.

  20. Neutron spin echo and high resolution inelastic spectroscopy

    International Nuclear Information System (INIS)

    Mezei, F.; Hungarian Academy of Sciences, Budapest. Central Research Inst. for Physics)

    1982-01-01

    The principles of neutrons spin echo (NSE) technique are considered. It is shown that the basis of NSE principle is a single step measurement of the change of the neutron velocity in the scattering process. The backscattering soectroscopy and the NSE techniques are compared. The NSF spectrometer is described. It is shown that 0.5 MeV energy resolution achieved in the NSE experiment is about 40 times superior to those achieved by the other techniques. The NSE technique has the unique feature that provides high resolution in neutron energy change independently of the monochromatization of the beam. The NSE instrument not only covers a wider dynamic range on a pulsed source that on a continuous one, but also collects data more efficiently

  1. High-resolution electron microscopy and its applications.

    Science.gov (United States)

    Li, F H

    1987-12-01

    A review of research on high-resolution electron microscopy (HREM) carried out at the Institute of Physics, the Chinese Academy of Sciences, is presented. Apart from the direct observation of crystal and quasicrystal defects for some alloys, oxides, minerals, etc., and the structure determination for some minute crystals, an approximate image-contrast theory named pseudo-weak-phase object approximation (PWPOA), which shows the image contrast change with crystal thickness, is described. Within the framework of PWPOA, the image contrast of lithium ions in the crystal of R-Li2Ti3O7 has been observed. The usefulness of diffraction analysis techniques such as the direct method and Patterson method in HREM is discussed. Image deconvolution and resolution enhancement for weak-phase objects by use of the direct method are illustrated. In addition, preliminary results of image restoration for thick crystals are given.

  2. High resolution CT in children with cystic fibrosis

    International Nuclear Information System (INIS)

    Stiglbauer, R.; Schurawitzki, H.; Eichler, I.; Goetz, M.

    1992-01-01

    High resolution CT (HRCT) was performed in 24 children (median age 57.9 months) suffering from cystic fibrosis (CF). In 23 patients (one examination unacceptable because of motion artifacts) the most frequent finding was bronchial wall thickening, shown in 21 patients (91%), followed by bronchiectasis in 15 patients (65%). Less frequent findings were mucus plugging and patchy consolidations, which could be demonstrated in 11 patients each (48%). Findings were classified using a CT scoring system and including only irreversible pulmonary changes; a statistically significant correlation with lung function tests could be established. HRCT to date seems to be the most valuable method to determine extent and severity of lung involvement in children with CF and should therefore be routinely used for the staging of this disease. (orig.)

  3. Chromatic Modulator for High Resolution CCD or APS Devices

    Science.gov (United States)

    Hartley, Frank T. (Inventor); Hull, Anthony B. (Inventor)

    2003-01-01

    A system for providing high-resolution color separation in electronic imaging. Comb drives controllably oscillate a red-green-blue (RGB) color strip filter system (or otherwise) over an electronic imaging system such as a charge-coupled device (CCD) or active pixel sensor (APS). The color filter is modulated over the imaging array at a rate three or more times the frame rate of the imaging array. In so doing, the underlying active imaging elements are then able to detect separate color-separated images, which are then combined to provide a color-accurate frame which is then recorded as the representation of the recorded image. High pixel resolution is maintained. Registration is obtained between the color strip filter and the underlying imaging array through the use of electrostatic comb drives in conjunction with a spring suspension system.

  4. Porous silicon phantoms for high-resolution scintillation imaging

    Energy Technology Data Exchange (ETDEWEB)

    Di Francia, G. [Portici Research Centre, ENEA, Via Vecchio Macello, 80055 Portici, Naples (Italy); Scafe, R. [Casaccia Research Centre, ENEA, 00060 S.Maria di Galeria, Rome (Italy)]. E-mail: scafe@casaccia.enea.it; De Vincentis, G. [Department of Radiological Sciences, University of Rome ' La Sapienza' , V.le Regina Elena, 324, 00161 Rome (Italy); La Ferrara, V. [Portici Research Centre, ENEA, Via Vecchio Macello, 80055 Portici, Naples (Italy); Iurlaro, G. [Casaccia Research Centre, ENEA, 00060 S.Maria di Galeria, Rome (Italy); Nasti, I. [Portici Research Centre, ENEA, Via Vecchio Macello, 80055 Portici, Naples (Italy); Montani, L. [Casaccia Research Centre, ENEA, 00060 S.Maria di Galeria, Rome (Italy); Pellegrini, R. [Department of Experimental Medicine, University of Rome ' La Sapienza' , V.le Regina Elena, 324, 00161 Rome (Italy); Betti, M. [Department of Experimental Medicine, University of Rome ' La Sapienza' , V.le Regina Elena, 324, 00161 Rome (Italy); Martucciello, N. [Portici Research Centre, ENEA, Via Vecchio Macello, 80055 Portici, Naples (Italy); Pani, R. [Department of Experimental Medicine, University of Rome ' La Sapienza' , V.le Regina Elena, 324, 00161 Rome (Italy)

    2006-12-20

    High resolution radionuclide imaging requires phantoms with precise geometries and known activities using either Anger cameras equipped with pinhole collimators or dedicated small animal devices. Porous silicon samples, having areas of different shape and size, can be made and loaded with a radioactive material, obtaining: (a) precise radio-emitting figures corresponding to the porous areas geometry (b) a radioactivity of each figure depending on the pore's specifications, and (c) the same emission energy to be used in true exams. To this aim a sample with porous circular areas has been made and loaded with a {sup 99m}TcO{sub 4} {sup -} solution. Imaging has been obtained using both general purpose and pinhole collimators. This first sample shows some defects that are analyzed and discussed.

  5. High-resolution 3-T MR neurography of peroneal neuropathy

    International Nuclear Information System (INIS)

    Chhabra, Avneesh; Faridian-Aragh, Neda; Chalian, Majid; Soldatos, Theodoros; Thawait, Shrey K.; Williams, Eric H.; Andreisek, Gustav

    2012-01-01

    The common peroneal nerve (CPN), a major terminal branch of the sciatic nerve, can be subject to a variety of pathologies, which may affect the nerve at any level from the lumbar plexus to its distal branches. Although the diagnosis of peripheral neuropathy is traditionally based on a patient's clinical findings and electrodiagnostic tests, magnetic resonance neurography (MRN) is gaining an increasing role in the definition of the type, site, and extent of peripheral nerve disorders. Current high-field MR scanners enable high-resolution and excellent soft-tissue contrast imaging of peripheral nerves. In the lower extremities, MR neurography has been employed in the demonstration of the anatomy and pathology of the CPN, as well as in the detection of associated secondary muscle denervation changes. This article reviews the normal appearance of the CPN as well as typical pathologies and abnormal findings at 3.0-T MR neurography of the lower extremity. (orig.)

  6. Meniscus tears of the knee: Postarthrogram high resolution CT

    International Nuclear Information System (INIS)

    Kim, Jae Hyoung; Do, Young Soo; You, Jin Jong; Gong, Jae Chul; Kim, Hyung Jin; Chung, Sung Hoon

    1990-01-01

    Thirty-eight knees with clinically suspected meniscal tears were examined with high resolution computed tomography(HRCT) immediately following double contrast arthrography. All subsequently underwent arthroscopy. The findings of postarthrogram HRCT and arthroscopy were compared to evaluated the usefulness of postarthrogram HRCT in diagnosis of the meniscal tears. The sensitivity, specificity and accuracy of HRCT were 96.2%. 83.3% and 92.1% respectively. The anatomic details of the meniscal tears were clearly visible on the HRCT scans. Sagittal and coronal reformation views well visualized the horizontal tears and the relationship of torn meniscal fragments, and well differential the peripheral tears from the synovial recess. Our result indicate that postarthrogram HRCT not only is a sensitive and effective method for the detection and characterization of the meniscal tears, but also provides arthroscopists with the appropriate surgical plans

  7. Quantitative high-resolution genomic analysis of single cancer cells.

    Science.gov (United States)

    Hannemann, Juliane; Meyer-Staeckling, Sönke; Kemming, Dirk; Alpers, Iris; Joosse, Simon A; Pospisil, Heike; Kurtz, Stefan; Görndt, Jennifer; Püschel, Klaus; Riethdorf, Sabine; Pantel, Klaus; Brandt, Burkhard

    2011-01-01

    During cancer progression, specific genomic aberrations arise that can determine the scope of the disease and can be used as predictive or prognostic markers. The detection of specific gene amplifications or deletions in single blood-borne or disseminated tumour cells that may give rise to the development of metastases is of great clinical interest but technically challenging. In this study, we present a method for quantitative high-resolution genomic analysis of single cells. Cells were isolated under permanent microscopic control followed by high-fidelity whole genome amplification and subsequent analyses by fine tiling array-CGH and qPCR. The assay was applied to single breast cancer cells to analyze the chromosomal region centred by the therapeutical relevant EGFR gene. This method allows precise quantitative analysis of copy number variations in single cell diagnostics.

  8. Quantitative high-resolution genomic analysis of single cancer cells.

    Directory of Open Access Journals (Sweden)

    Juliane Hannemann

    Full Text Available During cancer progression, specific genomic aberrations arise that can determine the scope of the disease and can be used as predictive or prognostic markers. The detection of specific gene amplifications or deletions in single blood-borne or disseminated tumour cells that may give rise to the development of metastases is of great clinical interest but technically challenging. In this study, we present a method for quantitative high-resolution genomic analysis of single cells. Cells were isolated under permanent microscopic control followed by high-fidelity whole genome amplification and subsequent analyses by fine tiling array-CGH and qPCR. The assay was applied to single breast cancer cells to analyze the chromosomal region centred by the therapeutical relevant EGFR gene. This method allows precise quantitative analysis of copy number variations in single cell diagnostics.

  9. High-resolution spectrum of the Galactic center

    Science.gov (United States)

    Mahoney, W. A.; Ling, J. C.; Wheaton, W. A.

    1993-01-01

    Recent observations of the Galactic center region indicate the presence of a narrow gamma-ray line feature at 170 keV, and theoretical speculations suggest it may result from Compton backscattering of the 511 keV annihilation radiation. The high-resolution gamma-ray spectrometer on HEAO 3 observed the Galactic center in the fall of 1979 and in the spring of 1980. In view of the recent developments, the HEAO data were re-examined to search for this new feature and to look for possible correlations with the 511 keV line emisison. No evidence for such Compton backscattered radiation was found and the derived upper limits for emission in a line feature near 170 keV were well below previously reported fluxes, indicating possible time variability.

  10. The inelastic contribution to high resolution images of defects

    International Nuclear Information System (INIS)

    Krivanek, O.L.; Ahn, C.C.; Wood, G.J.

    1990-01-01

    The importance of the contribution due to inelastically scattered electrons to unfiltered HREM images is examined, with emphasis on imaging of defects in semiconductors. Whenever the low energy loss spectrum contains sharp peaks, the contribution is not featureless. At specimen thickness of a few tens of nm, it may change the image appearance in a major way. The strongest effect occurs in high resolution, medium voltage (200 to 500 kV) electron microscope images of defects at focus values minimizing the contrast of the elastic image in low Z materials such as Al and Si. In higher Z materials or those with no sharp 'plasmons', the contribution is small. 23 refs., 8 figs

  11. High-Resolution Reciprocal Space Mapping for Characterizing Deformation Structures

    DEFF Research Database (Denmark)

    Pantleon, Wolfgang; Wejdemann, Christian; Jakobsen, Bo

    2014-01-01

    With high-angular resolution three-dimensional X-ray diffraction (3DXRD), quantitative information is gained about dislocation structures in individual grains in the bulk of a macroscopic specimen by acquiring reciprocal space maps. In high-resolution 3D reciprocal space maps of tensile......-deformed copper, individual, almost dislocation-free subgrains are identified from high-intensity peaks and distinguished by their unique combination of orientation and elastic strain; dislocation walls manifest themselves as a smooth cloud of lower intensity. The elastic strain shows only minor variations within...... dynamics is followed in situ during varying loading conditions by reciprocal space mapping: during uninterrupted tensile deformation, formation of subgrains is observed concurrently with broadening of Bragg reflections shortly after the onset of plastic deformation. When the traction is terminated, stress...

  12. Paracoccidioidomycosis: High-resolution computed tomography-pathologic correlation

    International Nuclear Information System (INIS)

    Marchiori, Edson; Valiante, Paulo Marcos; Mano, Claudia Mauro; Zanetti, Glaucia; Escuissato, Dante L.; Souza, Arthur Soares; Capone, Domenico

    2011-01-01

    Objective: The purpose of this study was to describe the high-resolution computed tomography (HRCT) features of pulmonary paracoccidioidomycosis and to correlate them with pathologic findings. Methods: The study included 23 adult patients with pulmonary paracoccidioidomycosis. All patients had undergone HRCT, and the images were retrospectively analyzed by two chest radiologists, who reached decisions by consensus. An experienced lung pathologist reviewed all pathological specimens. The HRCT findings were correlated with histopathologic data. Results: The predominant HRCT findings included areas of ground-glass opacities, nodules, interlobular septal thickening, airspace consolidation, cavitation, and fibrosis. The main pathological features consisted of alveolar and interlobular septal inflammatory infiltration, granulomas, alveolar exudate, cavitation secondary to necrosis, and fibrosis. Conclusion: Paracoccidioidomycosis can present different tomography patterns, which can involve both the interstitium and the airspace. These abnormalities can be pathologically correlated with inflammatory infiltration, granulomatous reaction, and fibrosis.

  13. High resolution imaging of tunnels by magnetic resonance neurography

    Energy Technology Data Exchange (ETDEWEB)

    Subhawong, Ty K.; Thawait, Shrey K.; Machado, Antonio J.; Carrino, John A.; Chhabra, Avneesh [Johns Hopkins Hospital, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Wang, Kenneth C. [Baltimore VA Medical Center, Department of Radiology, Baltimore, MD (United States); Williams, Eric H. [Dellon Institute for Peripheral Nerve Surgery, Towson, MD (United States); Hashemi, Shahreyar Shar [Johns Hopkins Hospital, Division of Plastic and Reconstructive Surgery, Baltimore, MD (United States)

    2012-01-15

    Peripheral nerves often traverse confined fibro-osseous and fibro-muscular tunnels in the extremities, where they are particularly vulnerable to entrapment and compressive neuropathy. This gives rise to various tunnel syndromes, characterized by distinct patterns of muscular weakness and sensory deficits. This article focuses on several upper and lower extremity tunnels, in which direct visualization of the normal and abnormal nerve in question is possible with high resolution 3T MR neurography (MRN). MRN can also serve as a useful adjunct to clinical and electrophysiologic exams by discriminating adhesive lesions (perineural scar) from compressive lesions (such as tumor, ganglion, hypertrophic callous, or anomalous muscles) responsible for symptoms, thereby guiding appropriate treatment. (orig.)

  14. High-resolution 3-T MR neurography of peroneal neuropathy

    Energy Technology Data Exchange (ETDEWEB)

    Chhabra, Avneesh; Faridian-Aragh, Neda; Chalian, Majid; Soldatos, Theodoros; Thawait, Shrey K. [Johns Hopkins Hospital, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Williams, Eric H. [Johns Hopkins Hospital, Department of Plastic Surgery, Baltimore, MD (United States); Dellon Institute for Peripheral Nerve Surgery, Baltimore, MD (United States); Andreisek, Gustav [University Hospital Zurich, Institute for Diagnostic Radiology, Department of Medical Radiology, Zurich (Switzerland)

    2012-03-15

    The common peroneal nerve (CPN), a major terminal branch of the sciatic nerve, can be subject to a variety of pathologies, which may affect the nerve at any level from the lumbar plexus to its distal branches. Although the diagnosis of peripheral neuropathy is traditionally based on a patient's clinical findings and electrodiagnostic tests, magnetic resonance neurography (MRN) is gaining an increasing role in the definition of the type, site, and extent of peripheral nerve disorders. Current high-field MR scanners enable high-resolution and excellent soft-tissue contrast imaging of peripheral nerves. In the lower extremities, MR neurography has been employed in the demonstration of the anatomy and pathology of the CPN, as well as in the detection of associated secondary muscle denervation changes. This article reviews the normal appearance of the CPN as well as typical pathologies and abnormal findings at 3.0-T MR neurography of the lower extremity. (orig.)

  15. High resolution imaging of tunnels by magnetic resonance neurography

    International Nuclear Information System (INIS)

    Subhawong, Ty K.; Thawait, Shrey K.; Machado, Antonio J.; Carrino, John A.; Chhabra, Avneesh; Wang, Kenneth C.; Williams, Eric H.; Hashemi, Shahreyar Shar

    2012-01-01

    Peripheral nerves often traverse confined fibro-osseous and fibro-muscular tunnels in the extremities, where they are particularly vulnerable to entrapment and compressive neuropathy. This gives rise to various tunnel syndromes, characterized by distinct patterns of muscular weakness and sensory deficits. This article focuses on several upper and lower extremity tunnels, in which direct visualization of the normal and abnormal nerve in question is possible with high resolution 3T MR neurography (MRN). MRN can also serve as a useful adjunct to clinical and electrophysiologic exams by discriminating adhesive lesions (perineural scar) from compressive lesions (such as tumor, ganglion, hypertrophic callous, or anomalous muscles) responsible for symptoms, thereby guiding appropriate treatment. (orig.)

  16. High resolution photoelectron spectroscopy of clusters of Group V elements

    International Nuclear Information System (INIS)

    Wang, Lai-sheng; Niu, B.; Lee, Y.T.; Shirley, D.A.

    1989-07-01

    High resolution HeI (580 angstrom) photoelectron spectra of As 2 , As 4 , and P 4 were obtained with a newly-built high temperature molecular beam source. Vibrational structure was resolved in the photoelectron spectra of the three cluster species. The Jahn-Teller effect is discussed for the 2 E and 2 T 2 states of P 4 + and As 4 + . As a result of the Jahn-Teller effect, the 2 E state splits into two bands, and the 2 T 2 state splits into three bands, in combination with the spin-orbit effect. It was observed that the ν 2 normal vibrational mode was involved in the vibronic interaction of the 2 E state, while both the ν 2 and ν 3 modes were active in the 2 T 2 state. 26 refs., 5 figs., 3 tabs

  17. Chandra High Resolution Imaging of NGC 1365 and NGC 4151

    Science.gov (United States)

    Wang, Junfeng; Fabbiano, G.; Elvis, M.; Risaliti, G.; Karovska, M.; Zezas, A.; Mazzarella, J. M.; Lord, S.; Howell, J. H.; Mundell, C. G.

    2010-07-01

    We present Chandra high resolution imaging of the circumnuclear regions of two nearby active galaxies, namely the starburst/AGN composite Seyfert 1.8 NGC 1365 and the archetypal Seyfert 1 NGC 4151. In NGC 1365, the X-ray morphology shows a biconical soft X-ray-emission region extending ~5 kpc in projection from the nucleus, coincident with the optical high-excitation outflows. Chandra HRC imaging of the NGC 4151 nucleus resolves X-ray emission from the 4 arcsec radio jet and the narrow line region (NLR) clouds. Our results demonstrate the unique power of spatially resolved spectroscopy with Chandra, and support previous claims that frequent jet-ISM interaction may explain why jets in Seyfert galaxies appear small, slow, and thermally dominated.

  18. High resolution ultrastructure imaging of fractures in human dental tissues

    Directory of Open Access Journals (Sweden)

    Tan Sui

    2014-01-01

    Full Text Available Human dental hard tissues are dentine, cementum, and enamel. These are hydrated mineralised composite tissues with a hierarchical structure and versatile thermo-mechanical properties. The hierarchical structure of dentine and enamel was imaged by transmission electron microscopy (TEM of samples prepared by focused ion beam (FIB milling. High resolution TEM was carried out in the vicinity of a crack tip in dentine. An intricate “random weave” pattern of hydroxyapatile crystallites was observed and this provided a possible explanation for toughening of the mineralized dentine tissue at the nano-scale. The results reported here provide the basis for improved understanding of the relationship between the multi-scale nature and the mechanical properties of hierarchically structured biomaterials, and will also be useful for the development of better prosthetic and dental restorative materials.

  19. A high resolution gridded ionization chamber for nuclear spectroscopy

    International Nuclear Information System (INIS)

    Vitale, E.R.

    1988-01-01

    This paper describes some techniques used in the design of high resolution gridded ionisation chambers for measurements of absolute activity of radionuclides. Details of the geometry of the system and its electrodes are presented; their shape and the spacing between the grid wire was studied with the help of an electrolytic tank. The experimental spectra obtained with an Am 241 source using Ar + 10% methane as a flow gas show a total resolution of 39,07 KeV in very good agreement with the best results available in the literature. An application of the methods developed was used in the design ans construction of a proportional counter provided with three sequential grids disposed in such a way that the pulses from the first stage had their amplitude multiplied by the two further stages. Multiplication factors of the order of 10 sup(3) were obtained but higher values are expected. (author)

  20. Evaluation of Esophageal Motor Function With High-resolution Manometry

    Science.gov (United States)

    2013-01-01

    For several decades esophageal manometry has been the test of choice to evaluate disorders of esophageal motor function. The recent introduction of high-resolution manometry for the study of esophageal motor function simplified performance of esophageal manometry, and revealed previously unidentified patterns of normal and abnormal esophageal motor function. Presentation of pressure data as color contour plots or esophageal pressure topography led to the development of new tools for analyzing and classifying esophageal motor patterns. The current standard and still developing approach to do this is the Chicago classification. While this methodical approach is improving our diagnosis of esophageal motor disorders, it currently does not address all motor abnormalities. We will explore the Chicago classification and disorders that it does not address. PMID:23875094

  1. High resolution imaging of surface patterns of single bacterial cells

    International Nuclear Information System (INIS)

    Greif, Dominik; Wesner, Daniel; Regtmeier, Jan; Anselmetti, Dario

    2010-01-01

    We systematically studied the origin of surface patterns observed on single Sinorhizobium meliloti bacterial cells by comparing the complementary techniques atomic force microscopy (AFM) and scanning electron microscopy (SEM). Conditions ranged from living bacteria in liquid to fixed bacteria in high vacuum. Stepwise, we applied different sample modifications (fixation, drying, metal coating, etc.) and characterized the observed surface patterns. A detailed analysis revealed that the surface structure with wrinkled protrusions in SEM images were not generated de novo but most likely evolved from similar and naturally present structures on the surface of living bacteria. The influence of osmotic stress to the surface structure of living cells was evaluated and also the contribution of exopolysaccharide and lipopolysaccharide (LPS) by imaging two mutant strains of the bacterium under native conditions. AFM images of living bacteria in culture medium exhibited surface structures of the size of single proteins emphasizing the usefulness of AFM for high resolution cell imaging.

  2. Bayesian Peptide Peak Detection for High Resolution TOF Mass Spectrometry.

    Science.gov (United States)

    Zhang, Jianqiu; Zhou, Xiaobo; Wang, Honghui; Suffredini, Anthony; Zhang, Lin; Huang, Yufei; Wong, Stephen

    2010-11-01

    In this paper, we address the issue of peptide ion peak detection for high resolution time-of-flight (TOF) mass spectrometry (MS) data. A novel Bayesian peptide ion peak detection method is proposed for TOF data with resolution of 10 000-15 000 full width at half-maximum (FWHW). MS spectra exhibit distinct characteristics at this resolution, which are captured in a novel parametric model. Based on the proposed parametric model, a Bayesian peak detection algorithm based on Markov chain Monte Carlo (MCMC) sampling is developed. The proposed algorithm is tested on both simulated and real datasets. The results show a significant improvement in detection performance over a commonly employed method. The results also agree with expert's visual inspection. Moreover, better detection consistency is achieved across MS datasets from patients with identical pathological condition.

  3. High-resolution imaging of solar system objects

    International Nuclear Information System (INIS)

    Goldberg, B.A.

    1988-01-01

    The strategy of this investigation has been to develop new high-resolution imaging capabilities and to apply them to extended observing programs. These programs have included Io's neutral sodium cloud and comets. The Io observing program was carried out at Table Mountain Observatory (1976 to 1981), providing a framework interpreting Voyager measurements of the Io torus, and serving as an important reference for studying asymmetries and time variabilities in the Jovian magnetosphere. Comet observations made with the 3.6 m Canada-France-Hawaii Telescope and 1.6 m AMOS telescope (1984 to 1987) provide basis for studying early coma development in Halley, the kinematics of its nucleus, and the internal and external structure of the nucleus. Images of GZ from the ICE encounter period form the basis for unique comparisons with in situ magnetic field and dust impact measurements to determine the ion tail and dust coma structure, respectively

  4. Polystyrene negative resist for high-resolution electron beam lithography

    Directory of Open Access Journals (Sweden)

    Ma Siqi

    2011-01-01

    Full Text Available Abstract We studied the exposure behavior of low molecular weight polystyrene as a negative tone electron beam lithography (EBL resist, with the goal of finding the ultimate achievable resolution. It demonstrated fairly well-defined patterning of a 20-nm period line array and a 15-nm period dot array, which are the densest patterns ever achieved using organic EBL resists. Such dense patterns can be achieved both at 20 and 5 keV beam energies using different developers. In addition to its ultra-high resolution capability, polystyrene is a simple and low-cost resist with easy process control and practically unlimited shelf life. It is also considerably more resistant to dry etching than PMMA. With a low sensitivity, it would find applications where negative resist is desired and throughput is not a major concern.

  5. Performance of a high resolution cavity beam position monitor system

    Science.gov (United States)

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Pete; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Honda, Yosuke; Kolomensky, Yury; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; Thomson, Mark; Urakawa, Junji; Vogel, Vladimir; Ward, David; White, Glen

    2007-07-01

    It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than 1 nm. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 μrad over a dynamic range of approximately ±20 μm.

  6. Validation of {sup 226}Ra, {sup 228}Ra and {sup 210}Pb measurements in soil and sediment samples through high resolution gamma ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Danila Carrijo da Silva; Silva, Nivaldo Carlos da; Bonifacio, Rodrigo Leandro; Guerrero, Eder Tadeu Zenun [Comissao Nacional de Energia Nuclear (LAPOC/CNEN-MG), Pocos de Caldas, MG (Brazil). Laboratorio de Pocos de Caldas

    2013-07-01

    Radionuclides found in ore extraction waste materials are a great source of concern regarding public health and environmental safety. One technique to determine the concentration of substances is high resolution gamma ray spectrometry using HPGe. Validating a measurement technique is essential to warrant high levels of quality to any scientific work. The Laboratory of Pocos de Caldas of the Brazilian Commission for Nuclear Energy partakes into a Quality Management System project, seeking Accreditation under ISO/IEC 17025 through the validation of techniques of chemical and radiometric analysis of environmental samples from water, soil and sediment. The focus of the Radon Laboratory at LAPOC is validation of Ra-226, Ra-228 and Pb-210 concentration determinations in soil and sediment through a gamma spectrometer system. The stages of this validation process included sample reception and preparation, detector calibration and sample analyses. Dried samples were sealed in metallic containers and analyzed after radioactive equilibrium between Ra-226 and daughters Pb-214 and Bi-214. Gamma spectrometry was performed using CANBERRA HPGe detector and gamma spectrum software Genie 2000. The photo peaks used for Ra-226 determination were 609 keV and 1020 keV of Bi-214 and 351 keV of Pb-214. For the Ra-228 determination a photopeak of 911 keV was used from its short half-life daughter Ac-228 (T1/2 = 6.12 h). For Pb-210, the photopeak of 46.5 keV was used, which, due to the low energy, self-absorption correction was needed. Parameters such as precision, bias/accuracy, linearity, detection limit and uncertainty were evaluated for that purpose. The results have pointed to satisfying results. (author)

  7. Validation of 226Ra, 228Ra and 210Pb measurements in soil and sediment samples through high resolution gamma ray spectrometry

    International Nuclear Information System (INIS)

    Dias, Danila Carrijo da Silva; Silva, Nivaldo Carlos da; Bonifacio, Rodrigo Leandro; Guerrero, Eder Tadeu Zenun

    2013-01-01

    Radionuclides found in ore extraction waste materials are a great source of concern regarding public health and environmental safety. One technique to determine the concentration of substances is high resolution gamma ray spectrometry using HPGe. Validating a measurement technique is essential to warrant high levels of quality to any scientific work. The Laboratory of Pocos de Caldas of the Brazilian Commission for Nuclear Energy partakes into a Quality Management System project, seeking Accreditation under ISO/IEC 17025 through the validation of techniques of chemical and radiometric analysis of environmental samples from water, soil and sediment. The focus of the Radon Laboratory at LAPOC is validation of Ra-226, Ra-228 and Pb-210 concentration determinations in soil and sediment through a gamma spectrometer system. The stages of this validation process included sample reception and preparation, detector calibration and sample analyses. Dried samples were sealed in metallic containers and analyzed after radioactive equilibrium between Ra-226 and daughters Pb-214 and Bi-214. Gamma spectrometry was performed using CANBERRA HPGe detector and gamma spectrum software Genie 2000. The photo peaks used for Ra-226 determination were 609 keV and 1020 keV of Bi-214 and 351 keV of Pb-214. For the Ra-228 determination a photopeak of 911 keV was used from its short half-life daughter Ac-228 (T1/2 = 6.12 h). For Pb-210, the photopeak of 46.5 keV was used, which, due to the low energy, self-absorption correction was needed. Parameters such as precision, bias/accuracy, linearity, detection limit and uncertainty were evaluated for that purpose. The results have pointed to satisfying results. (author)

  8. High resolution 3D imaging of synchrotron generated microbeams

    Energy Technology Data Exchange (ETDEWEB)

    Gagliardi, Frank M., E-mail: frank.gagliardi@wbrc.org.au [Alfred Health Radiation Oncology, The Alfred, Melbourne, Victoria 3004, Australia and School of Medical Sciences, RMIT University, Bundoora, Victoria 3083 (Australia); Cornelius, Iwan [Imaging and Medical Beamline, Australian Synchrotron, Clayton, Victoria 3168, Australia and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales 2500 (Australia); Blencowe, Anton [Division of Health Sciences, School of Pharmacy and Medical Sciences, The University of South Australia, Adelaide, South Australia 5000, Australia and Division of Information Technology, Engineering and the Environment, Mawson Institute, University of South Australia, Mawson Lakes, South Australia 5095 (Australia); Franich, Rick D. [School of Applied Sciences and Health Innovations Research Institute, RMIT University, Melbourne, Victoria 3000 (Australia); Geso, Moshi [School of Medical Sciences, RMIT University, Bundoora, Victoria 3083 (Australia)

    2015-12-15

    Purpose: Microbeam radiation therapy (MRT) techniques are under investigation at synchrotrons worldwide. Favourable outcomes from animal and cell culture studies have proven the efficacy of MRT. The aim of MRT researchers currently is to progress to human clinical trials in the near future. The purpose of this study was to demonstrate the high resolution and 3D imaging of synchrotron generated microbeams in PRESAGE® dosimeters using laser fluorescence confocal microscopy. Methods: Water equivalent PRESAGE® dosimeters were fabricated and irradiated with microbeams on the Imaging and Medical Beamline at the Australian Synchrotron. Microbeam arrays comprised of microbeams 25–50 μm wide with 200 or 400 μm peak-to-peak spacing were delivered as single, cross-fire, multidirectional, and interspersed arrays. Imaging of the dosimeters was performed using a NIKON A1 laser fluorescence confocal microscope. Results: The spatial fractionation of the MRT beams was clearly visible in 2D and up to 9 mm in depth. Individual microbeams were easily resolved with the full width at half maximum of microbeams measured on images with resolutions of as low as 0.09 μm/pixel. Profiles obtained demonstrated the change of the peak-to-valley dose ratio for interspersed MRT microbeam arrays and subtle variations in the sample positioning by the sample stage goniometer were measured. Conclusions: Laser fluorescence confocal microscopy of MRT irradiated PRESAGE® dosimeters has been validated in this study as a high resolution imaging tool for the independent spatial and geometrical verification of MRT beam delivery.

  9. Evaluation of a High-Resolution Regional Reanalysis for Europe

    Science.gov (United States)

    Ohlwein, C.; Wahl, S.; Keller, J. D.; Bollmeyer, C.

    2014-12-01

    Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. The regional reanalysis for Europe matches the domain of the CORDEX EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km) and comprises the assimilation of observational data using the existing nudging scheme of COSMO complemented by a special soil moisture analysis with boundary conditions provided by ERA-Interim data. The reanalysis data set covers 6 years (2007-2012) and is currently extended to 16 years. Extensive evaluation of the reanalysis is performed using independent observations with special emphasis on precipitation and high-impact weather situations indicating a better representation of small scale variability. Further, the evaluation shows an added value of the regional reanalysis with respect to the forcing ERA Interim reanalysis and compared to a pure high-resolution dynamical downscaling approach without data assimilation.

  10. The high-resolution regional reanalysis COSMO-REA6

    Science.gov (United States)

    Ohlwein, C.

    2016-12-01

    Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. The regional reanalysis for Europe matches the domain of the CORDEX EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km) and comprises the assimilation of observational data using the existing nudging scheme of COSMO complemented by a special soil moisture analysis with boundary conditions provided by ERA-Interim data. The reanalysis data set covers the past 20 years. Extensive evaluation of the reanalysis is performed using independent observations with special emphasis on precipitation and high-impact weather situations indicating a better representation of small scale variability. Further, the evaluation shows an added value of the regional reanalysis with respect to the forcing ERA Interim reanalysis and compared to a pure high-resolution dynamical downscaling approach without data assimilation.

  11. A High-resolution Reanalysis for the European CORDEX Region

    Science.gov (United States)

    Bentzien, Sabrina; Bollmeyer, Christoph; Crewell, Susanne; Friederichs, Petra; Hense, Andreas; Keller, Jan; Keune, Jessica; Kneifel, Stefan; Ohlwein, Christian; Pscheidt, Ieda; Redl, Stephanie; Steinke, Sandra

    2014-05-01

    A High-resolution Reanalysis for the European CORDEX Region Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. The work presented here focuses on the regional reanalysis for Europe with a domain matching the CORDEX-EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km). The COSMO reanalysis system comprises the assimilation of observational data using the existing nudging scheme of COSMO and is complemented by a special soil moisture analysis and boundary conditions given by ERA-interim data. The reanalysis data set currently covers 6 years (2007-2012). The evaluation of the reanalyses is done using independent observations with special emphasis on precipitation and high-impact weather situations. The development and evaluation of the COSMO-based reanalysis for the CORDEX-Euro domain can be seen as a preparation for joint European activities on the development of an ensemble system of regional reanalyses for Europe.

  12. A high-resolution regional reanalysis for Europe

    Science.gov (United States)

    Ohlwein, C.

    2015-12-01

    Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. The regional reanalysis for Europe matches the domain of the CORDEX EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km) and comprises the assimilation of observational data using the existing nudging scheme of COSMO complemented by a special soil moisture analysis with boundary conditions provided by ERA-Interim data. The reanalysis data set covers the past 20 years. Extensive evaluation of the reanalysis is performed using independent observations with special emphasis on precipitation and high-impact weather situations indicating a better representation of small scale variability. Further, the evaluation shows an added value of the regional reanalysis with respect to the forcing ERA Interim reanalysis and compared to a pure high-resolution dynamical downscaling approach without data assimilation.

  13. High-resolution RCMs as pioneers for future GCMs

    Science.gov (United States)

    Schar, C.; Ban, N.; Arteaga, A.; Charpilloz, C.; Di Girolamo, S.; Fuhrer, O.; Hoefler, T.; Leutwyler, D.; Lüthi, D.; Piaget, N.; Ruedisuehli, S.; Schlemmer, L.; Schulthess, T. C.; Wernli, H.

    2017-12-01

    Currently large efforts are underway to refine the horizontal resolution of global and regional climate models to O(1 km), with the intent to represent convective clouds explicitly rather than using semi-empirical parameterizations. This refinement will move the governing equations closer to first principles and is expected to reduce the uncertainties of climate models. High resolution is particularly attractive in order to better represent critical cloud feedback processes (e.g. related to global climate sensitivity and extratropical summer convection) and extreme events (such as heavy precipitation events, floods, and hurricanes). The presentation will be illustrated using decade-long simulations at 2 km horizontal grid spacing, some of these covering the European continent on a computational mesh with 1536x1536x60 grid points. To accomplish such simulations, use is made of emerging heterogeneous supercomputing architectures, using a version of the COSMO limited-area weather and climate model that is able to run entirely on GPUs. Results show that kilometer-scale resolution dramatically improves the simulation of precipitation in terms of the diurnal cycle and short-term extremes. The modeling framework is used to address changes of precipitation scaling with climate change. It is argued that already today, modern supercomputers would in principle enable global atmospheric convection-resolving climate simulations, provided appropriately refactored codes were available, and provided solutions were found to cope with the rapidly growing output volume. A discussion will be provided of key challenges affecting the design of future high-resolution climate models. It is suggested that km-scale RCMs should be exploited to pioneer this terrain, at a time when GCMs are not yet available at such resolutions. Areas of interest include the development of new parameterization schemes adequate for km-scale resolution, the exploration of new validation methodologies and data

  14. A high-resolution multimode digital microscope system.

    Science.gov (United States)

    Salmon, Edward D; Shaw, Sidney L; Waters, Jennifer C; Waterman-Storer, Clare M; Maddox, Paul S; Yeh, Elaine; Bloom, Kerry

    2013-01-01

    This chapter describes the development of a high-resolution, multimode digital imaging system based on a wide-field epifluorescent and transmitted light microscope, and a cooled charge-coupled device (CCD) camera. The three main parts of this imaging system are Nikon FXA microscope, Hamamatsu C4880 cooled CCD camera, and MetaMorph digital imaging system. This chapter presents various design criteria for the instrument and describes the major features of the microscope components-the cooled CCD camera and the MetaMorph digital imaging system. The Nikon FXA upright microscope can produce high resolution images for both epifluorescent and transmitted light illumination without switching the objective or moving the specimen. The functional aspects of the microscope set-up can be considered in terms of the imaging optics, the epi-illumination optics, the transillumination optics, the focus control, and the vibration isolation table. This instrument is somewhat specialized for microtubule and mitosis studies, and it is also applicable to a variety of problems in cellular imaging, including tracking proteins fused to the green fluorescent protein in live cells. The instrument is also valuable for correlating the assembly dynamics of individual cytoplasmic microtubules (labeled by conjugating X-rhodamine to tubulin) with the dynamics of membranes of the endoplasmic reticulum (labeled with DiOC6) and the dynamics of the cell cortex (by differential interference contrast) in migrating vertebrate epithelial cells. This imaging system also plays an important role in the analysis of mitotic mutants in the powerful yeast genetic system Saccharomyces cerevisiae. Copyright © 1998 Elsevier Inc. All rights reserved.

  15. Enhancing GIS Capabilities for High Resolution Earth Science Grids

    Science.gov (United States)

    Koziol, B. W.; Oehmke, R.; Li, P.; O'Kuinghttons, R.; Theurich, G.; DeLuca, C.

    2017-12-01

    Applications for high performance GIS will continue to increase as Earth system models pursue more realistic representations of Earth system processes. Finer spatial resolution model input and output, unstructured or irregular modeling grids, data assimilation, and regional coordinate systems present novel challenges for GIS frameworks operating in the Earth system modeling domain. This presentation provides an overview of two GIS-driven applications that combine high performance software with big geospatial datasets to produce value-added tools for the modeling and geoscientific community. First, a large-scale interpolation experiment using National Hydrography Dataset (NHD) catchments, a high resolution rectilinear CONUS grid, and the Earth System Modeling Framework's (ESMF) conservative interpolation capability will be described. ESMF is a parallel, high-performance software toolkit that provides capabilities (e.g. interpolation) for building and coupling Earth science applications. ESMF is developed primarily by the NOAA Environmental Software Infrastructure and Interoperability (NESII) group. The purpose of this experiment was to test and demonstrate the utility of high performance scientific software in traditional GIS domains. Special attention will be paid to the nuanced requirements for dealing with high resolution, unstructured grids in scientific data formats. Second, a chunked interpolation application using ESMF and OpenClimateGIS (OCGIS) will demonstrate how spatial subsetting can virtually remove computing resource ceilings for very high spatial resolution interpolation operations. OCGIS is a NESII-developed Python software package designed for the geospatial manipulation of high-dimensional scientific datasets. An overview of the data processing workflow, why a chunked approach is required, and how the application could be adapted to meet operational requirements will be discussed here. In addition, we'll provide a general overview of OCGIS

  16. COMPARATIVE ASSESSMENT OF VERY HIGH RESOLUTION SATELLITE AND AERIAL ORTHOIMAGERY

    Directory of Open Access Journals (Sweden)

    P. Agrafiotis

    2015-03-01

    Full Text Available This paper aims to assess the accuracy and radiometric quality of orthorectified high resolution satellite imagery from Pleiades-1B satellites through a comparative evaluation of their quantitative and qualitative properties. A Pleiades-B1 stereopair of high resolution images taken in 2013, two adjacent GeoEye-1 stereopairs from 2011 and aerial orthomosaic (LSO provided by NCMA S.A (Hellenic Cadastre from 2007 have been used for the comparison tests. As control dataset orthomosaic from aerial imagery provided also by NCMA S.A (0.25m GSD from 2012 was selected. The process for DSM and orthoimage production was performed using commercial digital photogrammetric workstations. The two resulting orthoimages and the aerial orthomosaic (LSO were relatively and absolutely evaluated for their quantitative and qualitative properties. Test measurements were performed using the same check points in order to establish their accuracy both as far as the single point coordinates as well as their distances are concerned. Check points were distributed according to JRC Guidelines for Best Practice and Quality Checking of Ortho Imagery and NSSDA standards while areas with different terrain relief and land cover were also included. The tests performed were based also on JRC and NSSDA accuracy standards. Finally, tests were carried out in order to assess the radiometric quality of the orthoimagery. The results are presented with a statistical analysis and they are evaluated in order to present the merits and demerits of the imaging sensors involved for orthoimage production. The results also serve for a critical approach for the usability and cost efficiency of satellite imagery for the production of Large Scale Orthophotos.

  17. High resolution micro ultrasonic machining for trimming 3D microstructures

    International Nuclear Information System (INIS)

    Viswanath, Anupam; Li, Tao; Gianchandani, Yogesh

    2014-01-01

    This paper reports on the evaluation of a high resolution micro ultrasonic machining (HR-µUSM) process suitable for post fabrication trimming of complex 3D microstructures made from fused silica. Unlike conventional USM, the HR-µUSM process aims for low machining rates, providing high resolution and high surface quality. The machining rate is reduced by keeping the micro-tool tip at a fixed distance from the workpiece and vibrating it at a small amplitude. The surface roughness is improved by an appropriate selection of abrasive particles. Fluidic modeling is performed to study interaction among the vibrating micro-tool tip, workpiece, and the slurry. Using 304 stainless steel (SS304) tool tips of 50 µm diameter, the machining performance of the HR-µUSM process is characterized on flat fused silica substrates. The depths and surface finish of machined features are evaluated as functions of slurry concentrations, separation between the micro-tool and workpiece, and machining time. Under the selected conditions, the HR-µUSM process achieves machining rates as low as 10 nm s −1  averaged over the first minute of machining of a flat virgin sample. This corresponds to a mass removal rate of ≈20 ng min −1 . The average surface roughness, S a , achieved is as low as 30 nm. Analytical and numerical modeling are used to explain the typical profile of the machined features as well as machining rates. The process is used to demonstrate trimming of hemispherical 3D shells made of fused silica. (paper)

  18. High resolution 3D imaging of synchrotron generated microbeams

    International Nuclear Information System (INIS)

    Gagliardi, Frank M.; Cornelius, Iwan; Blencowe, Anton; Franich, Rick D.; Geso, Moshi

    2015-01-01

    Purpose: Microbeam radiation therapy (MRT) techniques are under investigation at synchrotrons worldwide. Favourable outcomes from animal and cell culture studies have proven the efficacy of MRT. The aim of MRT researchers currently is to progress to human clinical trials in the near future. The purpose of this study was to demonstrate the high resolution and 3D imaging of synchrotron generated microbeams in PRESAGE® dosimeters using laser fluorescence confocal microscopy. Methods: Water equivalent PRESAGE® dosimeters were fabricated and irradiated with microbeams on the Imaging and Medical Beamline at the Australian Synchrotron. Microbeam arrays comprised of microbeams 25–50 μm wide with 200 or 400 μm peak-to-peak spacing were delivered as single, cross-fire, multidirectional, and interspersed arrays. Imaging of the dosimeters was performed using a NIKON A1 laser fluorescence confocal microscope. Results: The spatial fractionation of the MRT beams was clearly visible in 2D and up to 9 mm in depth. Individual microbeams were easily resolved with the full width at half maximum of microbeams measured on images with resolutions of as low as 0.09 μm/pixel. Profiles obtained demonstrated the change of the peak-to-valley dose ratio for interspersed MRT microbeam arrays and subtle variations in the sample positioning by the sample stage goniometer were measured. Conclusions: Laser fluorescence confocal microscopy of MRT irradiated PRESAGE® dosimeters has been validated in this study as a high resolution imaging tool for the independent spatial and geometrical verification of MRT beam delivery

  19. High resolution microphotonic needle for endoscopic imaging (Conference Presentation)

    Science.gov (United States)

    Tadayon, Mohammad Amin; Mohanty, Aseema; Roberts, Samantha P.; Barbosa, Felippe; Lipson, Michal

    2017-02-01

    GRIN (Graded index) lens have revolutionized micro endoscopy enabling deep tissue imaging with high resolution. The challenges of traditional GRIN lenses are their large size (when compared with the field of view) and their limited resolution. This is because of the relatively weak NA in standard graded index lenses. Here we introduce a novel micro-needle platform for endoscopy with much higher resolution than traditional GRIN lenses and a FOV that corresponds to the whole cross section of the needle. The platform is based on polymeric (SU-8) waveguide integrated with a microlens micro fabricated on a silicon substrate using a unique molding process. Due to the high index of refraction of the material the NA of the needle is much higher than traditional GRIN lenses. We tested the probe in a fluorescent dye solution (19.6 µM Alexa Flour 647 solution) and measured a numerical aperture of 0.25, focal length of about 175 µm and minimal spot size of about 1.6 µm. We show that the platform can image a sample with the field of view corresponding to the cross sectional area of the waveguide (80x100 µm2). The waveguide size can in principle be modified to vary size of the imaging field of view. This demonstration, combined with our previous work demonstrating our ability to implant the high NA needle in a live animal, shows that the proposed system can be used for deep tissue imaging with very high resolution and high field of view.

  20. Strengthening IAEA safeguards using high-resolution commercial satellite imagery

    International Nuclear Information System (INIS)

    Zhang Hui

    2001-01-01

    Full text: In May 1997, the IAEA Board of Governors adopted the Additional Safeguards Protocol to improve its ability to detect the undeclared production of fissile material. This new strengthened safeguards system has opened the door for the IAEA to use of all types of information, including the potential use of commercial satellite imagery. We have therefore been investigating the feasibility of strengthening IAEA safeguards using commercial satellite imagery. Based on our analysis on a number of one-meter resolution IKONOS satellite images of military nuclear production facilities at nuclear states including Russia, China, India, Pakistan and Israel, we found that the new high-resolution commercial satellite imagery would play a new and valuable role in strengthening IAEA safeguards. Since 1999, images with a resolution of one meter have been available commercially from Space Imaging's IKONOS satellite. One-meter images from other companies are expected to enter the market soon. Although still an order of magnitude less capable than military imaging satellites, the capabilities of these new high-resolution commercial satellites are good enough to detect and identify the major visible characteristics of nuclear production facilities and sites. Unlike the classified spy satellite photos limited to few countries, the commercial satellite imagery is commercially available to anyone who wants to purchase it. Therefore, the new commercial satellite open a new chance that each state, international organizations, and non-governmental groups could use the commercial images to play a more proactive role in monitoring the nuclear activities in related countries and verifying the compliance of non-proliferation agreements. This could help galvanize support for intensified efforts to slow the pace of nuclear proliferation. To produce fissile materials (plutonium and highly enriched uranium) for weapons, a country would operate dedicated plutonium-production reactors and the