WorldWideScience

Sample records for high-resolution computerized tomography

  1. Diagnostic performance comparison of the Chartis System and high-resolution computerized tomography fissure analysis for planning endoscopic lung volume reduction

    NARCIS (Netherlands)

    Gompelmann, Daniela; Eberhardt, Ralf; Slebos, Dirk-Jan; Brown, Matthew S.; Abtin, Fereidoun; Kim, Hyun J.; Holmes-Higgin, Debby; Radhakrishnan, Sri; Herth, Felix J. F.; Goldin, Jonathan

    Background and objective Endobronchial valve (EBV) therapy is optimized in patients who demonstrate little or no collateral ventilation (CV). The accuracy of the Chartis System and visual assessment of high-resolution computerized tomography (HRCT) fissure completeness by a core radiology laboratory

  2. Ultra high resolution tomography

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, W.S.

    1994-11-15

    Recent work and results on ultra high resolution three dimensional imaging with soft x-rays will be presented. This work is aimed at determining microscopic three dimensional structure of biological and material specimens. Three dimensional reconstructed images of a microscopic test object will be presented; the reconstruction has a resolution on the order of 1000 A in all three dimensions. Preliminary work with biological samples will also be shown, and the experimental and numerical methods used will be discussed.

  3. Bronchial asthma: correlation of high resolution computerized tomography findings with clinical data; Asma bronquica: correlacao de achados em tomografia computadorizada de alta resolucao com dados clinicos

    Energy Technology Data Exchange (ETDEWEB)

    Mogami, Roberto [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Servico de Radiologia; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Kirk, Kennedy; Capone, Domenico [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Servico de Pneumologia; Daltro, Pedro [Instituto Fernandes Figueira, Rio de Janeiro, RJ (Brazil). Servico de Radiologia

    1999-04-01

    In this work we did a sectional study of 31 asthmatic patients with several levels of disease severity, which were submitted to high resolution computed tomography of the thorax and spirometry, between the months of July, 1995 and August, 1997. The tomographic findings were correlated with the clinical classification of the patients and the most frequent tomographic findings were bronchial wall thickening, bronchial dilatation, air trapping, centrilobular opacities, cicatricial linear shadows, mucoid impaction, emphysema and atelectasis. In asthmatic patients of long duration we observed small airway disease and irreversible lesions as the predominant findings. In smoking patients there was no high frequency of emphysema. (author)

  4. High-resolution neutron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Mikerov, V.I. [P.N. Lebedev Physical Inst., RAN, Moscow (Russian Federation); Zhitnik, I.A. [P.N. Lebedev Physical Inst., RAN, Moscow (Russian Federation); Ignat`ev, A.P. [P.N. Lebedev Physical Inst., RAN, Moscow (Russian Federation); Isakov, A.I. [P.N. Lebedev Physical Inst., RAN, Moscow (Russian Federation); Korneev, V.V. [P.N. Lebedev Physical Inst., RAN, Moscow (Russian Federation); Krutov, V.V. [P.N. Lebedev Physical Inst., RAN, Moscow (Russian Federation); Kuzin, S.V. [P.N. Lebedev Physical Inst., RAN, Moscow (Russian Federation); Oparin, S.N. [P.N. Lebedev Physical Inst., RAN, Moscow (Russian Federation); Pertsov, A.A. [P.N. Lebedev Physical Inst., RAN, Moscow (Russian Federation); Podolyak, E.R. [P.N. Lebedev Physical Inst., RAN, Moscow (Russian Federation); Sobel`man, I.I. [P.N. Lebedev Physical Inst., RAN, Moscow (Russian Federation); Tindo, I.P. [P.N. Lebedev Physical Inst., RAN, Moscow (Russian Federation); Tukarev, B.A. [P.N. Lebedev Physical Inst., RAN, Moscow (Russian Federation)

    1995-12-31

    A neutron tomography technique with a coordinate resolution of several tens of micrometers has been developed. Our results indicate that the technique resolves details with dimensions less than 100 {mu}m and measures a linear attenuation of less than {approx} 0.1 cm{sup -1}. Tomograms can be reconstructed using incomplete data. Limits on the resolution of the restored pattern are analyzed, and ways to improve the sensitivity of the technique are discussed. (orig.).

  5. High resolution, MRI-based, segmented, computerized head phantom

    Energy Technology Data Exchange (ETDEWEB)

    Zubal, I.G.; Harrell, C.R.; Smith, E.O.; Smith, A.L.; Krischlunas, P. [Yale Univ., New Haven, CT (United States). Dept. of Diagnostic Radiology

    1999-01-01

    The authors have created a high-resolution software phantom of the human brain which is applicable to voxel-based radiation transport calculations yielding nuclear medicine simulated images and/or internal dose estimates. A software head phantom was created from 124 transverse MRI images of a healthy normal individual. The transverse T2 slices, recorded in a 256x256 matrix from a GE Signa 2 scanner, have isotropic voxel dimensions of 1.5 mm and were manually segmented by the clinical staff. Each voxel of the phantom contains one of 62 index numbers designating anatomical, neurological, and taxonomical structures. The result is stored as a 256x256x128 byte array. Internal volumes compare favorably to those described in the ICRP Reference Man. The computerized array represents a high resolution model of a typical human brain and serves as a voxel-based anthropomorphic head phantom suitable for computer-based modeling and simulation calculations. It offers an improved realism over previous mathematically described software brain phantoms, and creates a reference standard for comparing results of newly emerging voxel-based computations. Such voxel-based computations lead the way to developing diagnostic and dosimetry calculations which can utilize patient-specific diagnostic images. However, such individualized approaches lack fast, automatic segmentation schemes for routine use; therefore, the high resolution, typical head geometry gives the most realistic patient model currently available.

  6. Clinical evaluation of a high-resolution new peripheral quantitative computerized tomography (pQCT) scanner for the bone densitometry at the lower limbs

    Science.gov (United States)

    Braun, M. J.; Meta, M. D.; Schneider, P.; Reiners, Chr

    1998-08-01

    Precision, long-term stability, linearity and accuracy of the x-ray peripheral quantitative computerized tomographic (pQCT) bone scanner XCT 3000 (Norland-Stratec Medical Sys.) were evaluated using the European Forearm Phantom (EFP). In vivo measurements were assessed using a standardized procedure at the distal femur and the distal tibia. In the patient-scan mode, the spatial resolution of the system was lp/mm as measured at the 10% level of the modulation transfer function (MTF). The contrast-detail diagram (CDD) yielded a minimal difference in attenuation coefficient (AC) of 0.07 at an object size of 0.5 mm. The effective dose for humans was calculated to be less than 1.5 Sv per scan. Short-term precision in vivo was expressed as root mean square standard deviation of paired measurements of 20 healthy volunteers (%). At the distal femur total volumetric density (ToD) and total cross-sectional area (ToA) were found to be less sensitive to positioning errors than at the distal tibia. Structural parameters like the polar cross-sectional moment of inertia or the polar cross-sectional moment of resistance showed a good short-term precision at the distal femur ( and 1.4%). The relation between the two skeletal sites with respect to or showed a high coefficient of determination ( and 0.74).

  7. Computerized ionospheric tomography

    Energy Technology Data Exchange (ETDEWEB)

    Austen, J.R.; Raymund, T.D.; Klobuchar, J.A.; Stalker, J.; Liu, C.H.

    1990-05-03

    In this paper the background of computerized tomography (CT) and its application to the ionosphere is reviewed. CT techniques, using only total electron content (TEC) data, can be used to reconstruct a two-dimensional image of the electron density in the ionosphere. The limitations of this technique are discussed and examples showing the limitations and capabilities are presented. Simulation results for two applications are presented: imaging the high latitude trough, and the correction of tracking radar range rate errors. Some possible extensions of the technique are presented.

  8. High-resolution nuclear magnetic resonance imaging and single photon emission computerized tomography--cerebral blood flow in a case of pure sensory stroke and mild dementia owing to subcortical arteriosclerotic encephalopathy (Binswanger's disease)

    DEFF Research Database (Denmark)

    De Chiara, S; Lassen, N A; Andersen, A R

    1987-01-01

    involving visiospatial apraxia; this pointed to decreased function of the right parietal cortex, which was structurally intact on CT and NMRI. Single photon emission computerized tomography by Xenon-133 injection and by hexamethyl-propyleneamine-oxim labeled with Technetium-99m showed asymmetric...

  9. High resolution IVEM tomography of biological specimens

    Energy Technology Data Exchange (ETDEWEB)

    Sedat, J.W.; Agard, D.A. [Univ. of California, San Francisco, CA (United States)

    1997-02-01

    Electron tomography is a powerful tool for elucidating the three-dimensional architecture of large biological complexes and subcellular organelles. The introduction of intermediate voltage electron microscopes further extended the technique by providing the means to examine very large and non-symmetrical subcellular organelles, at resolutions beyond what would be possible using light microscopy. Recent studies using electron tomography on a variety of cellular organelles and assemblies such as centrosomes, kinetochores, and chromatin have clearly demonstrated the power of this technique for obtaining 3D structural information on non-symmetric cell components. When combined with biochemical and molecular observations, these 3D reconstructions have provided significant new insights into biological function.

  10. Optical diffraction tomography for high resolution live cell imaging

    Science.gov (United States)

    Sung, Yongjin; Choi, Wonshik; Fang-Yen, Christopher; Badizadegan, Kamran; Dasari, Ramachandra R.; Feld, Michael S.

    2009-01-01

    We report the experimental implementation of optical diffraction tomography for quantitative 3D mapping of refractive index in live biological cells. Using a heterodyne Mach-Zehnder interferometer, we record complex field images of light transmitted through a sample with varying directions of illumination. To quantitatively reconstruct the 3D map of complex refractive index in live cells, we apply optical diffraction tomography based on the Rytov approximation. In this way, the effect of diffraction is taken into account in the reconstruction process and diffraction-free high resolution 3D images are obtained throughout the entire sample volume. The quantitative refractive index map can potentially serve as an intrinsic assay to provide the molecular concentrations without the addition of exogenous agents and also to provide a method for studying the light scattering properties of single cells. PMID:19129896

  11. Quantitative analysis of cholesteatoma using high resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Shigeru; Yamasoba, Tatsuya (Kameda General Hospital, Chiba (Japan)); Iinuma, Toshitaka

    1992-05-01

    Seventy-three cases of adult cholesteatoma, including 52 cases of pars flaccida type cholesteatoma and 21 of pars tensa type cholesteatoma, were examined using high resolution computed tomography, in both axial (lateral semicircular canal plane) and coronal sections (cochlear, vestibular and antral plane). These cases were classified into two subtypes according to the presence of extension of cholesteatoma into the antrum. Sixty cases of chronic otitis media with central perforation (COM) were also examined as controls. Various locations of the middle ear cavity were measured in terms of size in comparison with pars flaccida type cholesteatoma, pars tensa type cholesteatoma and COM. The width of the attic was significantly larger in both pars flaccida type and pars tensa type cholesteatoma than in COM. With pars flaccida type cholesteatoma there was a significantly larger distance between the malleus and lateral wall of the attic than with COM. In contrast, the distance between the malleus and medial wall of the attic was significantly larger with pars tensa type cholesteatoma than with COM. With cholesteatoma extending into the antrum, regardless of the type of cholesteatoma, there were significantly larger distances than with COM at the following sites: the width and height of the aditus ad antrum, and the width, height and anterior-posterior diameter of the antrum. However, these distances were not significantly different between cholesteatoma without extension into the antrum and COM. The hitherto demonstrated qualitative impressions of bone destruction in cholesteatoma were quantitatively verified in detail using high resolution computed tomography. (author).

  12. Tuberculose pulmonar: achados na tomografia computadorizada de alta resolução do tórax em pacientes com doença em atividade comprovada bacteriologicamente Pulmonary tuberculosis: findings on high resolution computerized tomography of active disease on patients with bacteriological confirmation

    Directory of Open Access Journals (Sweden)

    CRISTIANE ALÓ CAMPOS

    2002-01-01

    Full Text Available Objetivo: Descrever os achados em pacientes com tuberculose pulmonar em atividade na tomografia computadorizada de alta resolução e o padrão de distribuição das lesões pelo parênquima pulmonar. Casuística e método: Foram analisadas retrospectivamente as tomografias de alta resolução de 42 pacientes com diagnóstico bacteriológico de tuberculose pulmonar ou forte suspeita clínica, com posterior confirmação bacteriológica. Resultados: Os principais sinais sugestivos de atividade encontrados foram nódulos do espaço aéreo (83%, nódulos centrolobulares (74%, aspecto de árvore em brotamento (67%, cavitações (67%, espessamento das paredes brônquicas (55%, consolidações (48%, opacidade em vidro fosco (21%, e espessamento do interstício pulmonar (9%. Conclusão: A tomografia computadorizada de alta resolução do tórax pode sugerir fortemente atividade da doença, sendo particularmente útil nos pacientes com baciloscopias negativas e/ou radiografias indeterminadas, permitindo a instituição de tratamento adequado, antes mesmo do crescimento da micobactéria em meio de cultura.Background: The aim of this study was to describe the signs of active tuberculosis in patients submitted to high resolution computerized tomography and the distribution of lesions along the pulmonary parenchyma. Material and methods: The high resolution CTs performed on 42 patients with tuberculosis either bacteriologically diagnosed or clinical suspected and later confirmed by bacteriological tests were studied. Results: The signs of disease activity observed were airspace nodule (83%, centrilobular nodule (74%, tree-in-bud pattern (67%, cavitations (67%, bronchial thickening (55%, parenchymal consolidations (48%, ground glass opacity (21% and thickening of the inter and intralobular septa (9%. Conclusion: High resolution computed tomography can be strongly suggestive of disease activity, is particularly helpful in patients with negative smear and

  13. Diagnostic value of high resolutional computed tomography of spine

    Energy Technology Data Exchange (ETDEWEB)

    Yang, S. M.; Im, S. K.; Sohn, M. H.; Lim, K. Y.; Kim, J. K.; Choi, K. C. [Jeonbug National University College of Medicine, Seoul (Korea, Republic of)

    1984-03-15

    Non-enhanced high resolution computed tomography provide clear visualization of soft tissue in the canal and bony details of spine, particularly of the lumbar spine. We observed 70 cases of spine CT using GE CT/T 8800 scanner during the period from Dec. 1982 to Sep. 1983 at Jeonbug National University Hospital. The results were as follows: 1. The sex distribution of cases were 55 males and 15 females : age was from 17 years to 67 years; sites were 11 cervical spine, 5 thoracic spine and 54 lumbosacral spine. 2. CT diagnosis showed 44 cases of lumbar disc herniation, 7 cases of degenerative disease, 3 cases of spine fracture and each 1 cases of cord tumor, metastatic tumor, spontaneous epidural hemorrhage, epidural abscess, spine tbc., meningocele with diastematomyelia. 3. Sites of herniated nucleus pulposus were 34 cases (59.6%) between L4-5 interspace and 20 cases (35.1%) between L5-S1 interspace. 13 cases (29.5%) of lumbar disc herniation disclosed multiple lesions. Location of herniation were central type in 28 cases(49.1%), right-central type in 12 cases(21.2%), left-central type in 11 cases (19.2%) and far lateral type in 6 cases(10.5%). 4. CT findings of herniated nucleus pulposus were as follows : focal protrusion of posterior disc margin and obliteration of anterior epidural fat in all cases, dural sac indentation in 26 cases(45.6%), soft tissue mass in epidural fat in 21 cases(36.8%), displacement or compression of nerve root sheath in 12 cases(21%). 5. Multiplanar reformatted images and Blink mode provide more effective evaluation about definite level and longitudinal dimension of lesion, such as obscure disc herniation, spine fracture, cord tumor and epidural abscess. 6. Non-enhanced and enhanced high resolutional computed tomography were effectively useful in demonstrating compression or displacement of spinal cord and nerve root, examing congenital anomaly such as meningocele and primary or metastatic spinal lesions.

  14. High-resolution multimodal clinical multiphoton tomography of skin

    Science.gov (United States)

    König, Karsten

    2011-03-01

    This review focuses on multimodal multiphoton tomography based on near infrared femtosecond lasers. Clinical multiphoton tomographs for 3D high-resolution in vivo imaging have been placed into the market several years ago. The second generation of this Prism-Award winning High-Tech skin imaging tool (MPTflex) was introduced in 2010. The same year, the world's first clinical CARS studies have been performed with a hybrid multimodal multiphoton tomograph. In particular, non-fluorescent lipids and water as well as mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen has been imaged with submicron resolution in patients suffering from psoriasis. Further multimodal approaches include the combination of multiphoton tomographs with low-resolution wide-field systems such as ultrasound, optoacoustical, OCT, and dermoscopy systems. Multiphoton tomographs are currently employed in Australia, Japan, the US, and in several European countries for early diagnosis of skin cancer, optimization of treatment strategies, and cosmetic research including long-term testing of sunscreen nanoparticles as well as anti-aging products.

  15. High resolution functional photoacoustic tomography of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiaoqi; Yao, Lei; Xi, Lei; Jiang, Huabei, E-mail: hjiang@bme.ufl.edu [Department of Biomedical Engineering, University of Florida, Gainesville, Florida 32611 (United States); Heldermon, Coy D. [Department of Medicine, University of Florida, Gainesville, Florida 32611 (United States)

    2015-09-15

    Purpose: To evaluate the feasibility of functional photoacoustic tomography (fPAT) for high resolution detection and characterization of breast cancer and to demonstrate for the first time quantitative hemoglobin concentration and oxygen saturation images of breasts that were formed with model-based reconstruction of tomographic photoacoustic data. Methods: The study was HIPAA compliant and was approved by the university institutional review board. Written informed consents were obtained from all the participants. Ten cases, including six cancer and four healthy (mean age = 50 yr; age range = 41–66 yr), were examined. Functional images of breast tissue including absolute total hemoglobin concentration (Hb{sub T}) and oxygen saturation (StO{sub 2}%) were obtained by fPAT and cross validated with magnetic resonance imaging (MRI) readings and/or histopathology. Results: Hb{sub T} and StO{sub 2}% maps from all six pathology-confirmed cancer cases (60%) show clear detection of tumor, while MR images indicate clear detection of tumor for five of six cancer cases; one small tumor was read as near-complete-resolution by MRI. The average Hb{sub T} and StO{sub 2}% value of suspicious lesion area for the cancer cases was 61.6 ± 18.9 μM/l and 67.5% ± 5.2% compared to 25.6 ± 7.4 μM/l and 65.2% ± 3.8% for background normal tissue. Conclusions: fPAT has the potential to be a significant add-on in breast cancer detection and characterization as it provides submillimeter resolution functional images of breast lesions.

  16. Accelerated high-resolution photoacoustic tomography via compressed sensing.

    Science.gov (United States)

    Arridge, Simon; Beard, Paul; Betcke, Marta; Cox, Ben; Huynh, Nam; Lucka, Felix; Ogunlade, Olumide; Zhang, Edward

    2016-12-21

    Current 3D photoacoustic tomography (PAT) systems offer either high image quality or high frame rates but are not able to deliver high spatial and temporal resolution simultaneously, which limits their ability to image dynamic processes in living tissue (4D PAT). A particular example is the planar Fabry-Pérot (FP) photoacoustic scanner, which yields high-resolution 3D images but takes several minutes to sequentially map the incident photoacoustic field on the 2D sensor plane, point-by-point. However, as the spatio-temporal complexity of many absorbing tissue structures is rather low, the data recorded in such a conventional, regularly sampled fashion is often highly redundant. We demonstrate that combining model-based, variational image reconstruction methods using spatial sparsity constraints with the development of novel PAT acquisition systems capable of sub-sampling the acoustic wave field can dramatically increase the acquisition speed while maintaining a good spatial resolution: first, we describe and model two general spatial sub-sampling schemes. Then, we discuss how to implement them using the FP interferometer and demonstrate the potential of these novel compressed sensing PAT devices through simulated data from a realistic numerical phantom and through measured data from a dynamic experimental phantom as well as from in vivo experiments. Our results show that images with good spatial resolution and contrast can be obtained from highly sub-sampled PAT data if variational image reconstruction techniques that describe the tissues structures with suitable sparsity-constraints are used. In particular, we examine the use of total variation (TV) regularization enhanced by Bregman iterations. These novel reconstruction strategies offer new opportunities to dramatically increase the acquisition speed of photoacoustic scanners that employ point-by-point sequential scanning as well as reducing the channel count of parallelized schemes that use detector arrays.

  17. Accelerated high-resolution photoacoustic tomography via compressed sensing

    Science.gov (United States)

    Arridge, Simon; Beard, Paul; Betcke, Marta; Cox, Ben; Huynh, Nam; Lucka, Felix; Ogunlade, Olumide; Zhang, Edward

    2016-12-01

    Current 3D photoacoustic tomography (PAT) systems offer either high image quality or high frame rates but are not able to deliver high spatial and temporal resolution simultaneously, which limits their ability to image dynamic processes in living tissue (4D PAT). A particular example is the planar Fabry-Pérot (FP) photoacoustic scanner, which yields high-resolution 3D images but takes several minutes to sequentially map the incident photoacoustic field on the 2D sensor plane, point-by-point. However, as the spatio-temporal complexity of many absorbing tissue structures is rather low, the data recorded in such a conventional, regularly sampled fashion is often highly redundant. We demonstrate that combining model-based, variational image reconstruction methods using spatial sparsity constraints with the development of novel PAT acquisition systems capable of sub-sampling the acoustic wave field can dramatically increase the acquisition speed while maintaining a good spatial resolution: first, we describe and model two general spatial sub-sampling schemes. Then, we discuss how to implement them using the FP interferometer and demonstrate the potential of these novel compressed sensing PAT devices through simulated data from a realistic numerical phantom and through measured data from a dynamic experimental phantom as well as from in vivo experiments. Our results show that images with good spatial resolution and contrast can be obtained from highly sub-sampled PAT data if variational image reconstruction techniques that describe the tissues structures with suitable sparsity-constraints are used. In particular, we examine the use of total variation (TV) regularization enhanced by Bregman iterations. These novel reconstruction strategies offer new opportunities to dramatically increase the acquisition speed of photoacoustic scanners that employ point-by-point sequential scanning as well as reducing the channel count of parallelized schemes that use detector arrays.

  18. COMPARISON OF HIGH RESOLUTION PERIPHERAL QUANTITATIVE COMPTERIZED TOMOGRAPHY (HR-pQCT) WITH DUAL ENERGY X-RAY ABSORPTIOMETRY (DXA) FOR MEASURING BONE MINERAL DENSITY (BMD)

    OpenAIRE

    Colt, E; Akram, M.; Pi Sunyer, FX

    2016-01-01

    OBJECTIVE was to compare the measurement of areal bone mineral density (aBMD) by dual energy X-ray absorptiometry (DXA) with the measurement of volumetric bone mineral density (vBMD) by high resolution peripheral computerised tomography(HR-pQCT) in subjects with a wide range of body mass indices (BMI). SUBJECTS We scanned the arms and legs of 49 premenopausal women, aged 21-45, with BMI from 18.5-46.5, by high resolution peripheral computerized tomography (HR-pQCT) and found that there was a ...

  19. Spectral domain optical coherence tomography - Ultra-high speed, ultra-high resolution ophthalmic imaging

    NARCIS (Netherlands)

    Chen, T.; Cense, B.; Pierce, M. C.; Nassif, N. A.; Park, B. H.; Yun, S. H.; White, B.; Bouma, B. E.; Tearney, G. J.; de Boer, J.F.

    2005-01-01

    Objective: To introduce a new ophthalmic optical coherence tomography technology that allows unprecedented simultaneous ultra-high speed and ultra-high resolution. Methods: Using a superluminescent diode source, a clinically viable ultra-high speed, ultra-high resolution spectral domain optical

  20. Bronchiolitis obliterans following exposure to sulfur mustard: chest high resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ghanei, Mostafa E-mail: m.ghanei@bmsu.ac.ir; Mokhtari, Majid; Mohammad, Mehdi Mir; Aslani, Jafar

    2004-11-01

    Background: Pulmonary complications are known to occur in over half of the patients exposed to sulfur mustard (SM). Chemical weapons of mass destruction (WMD) including SM were used by Iraq during Iran-Iraq war between 1983 and 1989. We undertook this study to evaluate the chest high resolution computerized tomography (HRCT) as a diagnostic tool in patients with documented exposure to SM and chronic respiratory symptoms. Method: The medical records of 155 patients exposed to SM during Iran-Iraq war and suffered respiratory complications were reviewed. Chest HRCTs of these patients were examined. Ten healthy controls with no history of exposure to HD were matched for age, gender, and chest HRCT protocol applied. Results: Fifty chest HRCTs of these patients were randomly selected for this study. The most frequent findings were; air trapping 38 (76%), bronchiectasis 37 (74%), mosaic parenchymal attenuation (MPA) 36 (72%), irregular and dilated major airways 33 (66%) bronchial wall thickening (BWT) 45 (90%), and interlobular septal wall thickening (SWT) 13 (26%), respectively. Air trapping in one patient (10%) was the only positive finding in the control group. Conclusions: Chest HRCT findings of bronchiectasis, air trapping, MPA, SWT, and BWT were seen in our patients 15 years after exposure to HD. These findings suggest the diagnosis of bronchiolitis obliterans (BO). We did not encounter chest HRCT features consistent with pulmonary fibrosis.

  1. [Recurrence of rectal cancer in computerized tomography].

    Science.gov (United States)

    Kuckein, D

    1981-04-01

    In contrast to conventional methods of x-ray diagnosis, recurrence of a rectum carcinoma may be visualized directly by means of computerized tomography. CT criteria of a tumor relapse are discussed. Based on own cases, it is shown that the method is usually employed too late. CT as follow-up examination should be used as a routine procedure in order to establish an early diagnosis of tumor recurrence.

  2. High-resolution computed tomography and histopathological findings in hypersensitivity pneumonitis: a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Pedro Paulo Teixeira e Silva; Moreira, Marise Amaral Reboucas; Silva, Daniela Graner Schuwartz Tannus; Moreira, Maria Auxiliadora do Carmo [Universidade Federal de Goias (UFG), Goiania, GO (Brazil); Gama, Roberta Rodrigues Monteiro da [Hospital do Cancer de Barretos, Barretos, SP (Brazil); Sugita, Denis Masashi, E-mail: pedroptstorres@yahoo.com.br [Anapolis Unievangelica, Anapolis, GO (Brazil)

    2016-03-15

    Hypersensitivity pneumonitis is a diffuse interstitial and granulomatous lung disease caused by the inhalation of any one of a number of antigens. The objective of this study was to illustrate the spectrum of abnormalities in high-resolution computed tomography and histopathological findings related to hypersensitivity pneumonitis. We retrospectively evaluated patients who had been diagnosed with hypersensitivity pneumonitis (on the basis of clinical-radiological or clinical-radiological-pathological correlations) and had undergone lung biopsy. Hypersensitivity pneumonitis is clinically divided into acute, subacute, and chronic forms; high-resolution computed tomography findings correlate with the time of exposure; and the two occasionally overlap. In the subacute form, centrilobular micronodules, ground glass opacities, and air trapping are characteristic high-resolution computed tomography findings, whereas histopathology shows lymphocytic inflammatory infiltrates, bronchiolitis, variable degrees of organizing pneumonia, and giant cells. In the chronic form, high-resolution computed tomography shows traction bronchiectasis, honeycombing, and lung fibrosis, the last also being seen in the biopsy sample. A definitive diagnosis of hypersensitivity pneumonitis can be made only through a multidisciplinary approach, by correlating clinical findings, exposure history, high-resolution computed tomography findings, and lung biopsy findings. (author)

  3. Very High Resolution SAR Tomography via Compressive Sensing

    Science.gov (United States)

    Zhu, Xiao Xiang; Bamler, Richard

    2010-03-01

    By using multi-pass SAR acquisitions, SAR tomography (TomoSAR) extends the synthetic aperture principle into the elevation direction for 3-D imaging. Since the orbits of modern space-borne SAR systems, like TerraSAR-X, are tightly controlled, the elevation resolution (depending on the elevation aperture size) is at least an order of magnitude lower than in range and azimuth. Hence, super- resolution algorithms are desired. The high anisotropic 3- D resolution element renders the signals sparse in elevation. This property suggests using compressive sensing (CS) methods. The paper presents the theory of 4- D (i.e. space-time) CS TomoSAR and compares it with classical tomographic methods. Super-resolution properties and point localization accuracies are demonstrated using simulations and real data. A CS reconstruction of a building complex from TerraSAR-X spotlight data is presented. In addition, the model based time warp method for differential tomographic non-linear motion monitoring is proposed and validated by reconstructing seasonal motion (caused by thermal expansion) of a building complex.

  4. High-resolution full-field spatial coherence gated optical tomography using monochromatic light source

    Science.gov (United States)

    Srivastava, Vishal; Nandy, Sreyankar; Singh Mehta, Dalip

    2013-09-01

    We demonstrate dispersion free, high-resolution full-field spatial coherence gated optical tomography using spatially incoherent monochromatic light source. Spatial coherence properties of light source were synthesized by means of combining a static diffuser and vibrating multi mode fiber bundle. Due to low spatial coherence of light source, the axial resolution of the system was achieved similar to that of conventional optical coherence tomography which utilizes low temporal coherence. Experimental results of fringe visibility versus optical path difference are presented for varying numerical apertures objective lenses. High resolution optically sectioned images of multilayer onion skin, and red blood cells are presented.

  5. High-resolution PET [Positron Emission Tomography] for Medical Science Studies

    Science.gov (United States)

    Budinger, T. F.; Derenzo, S. E.; Huesman, R. H.; Jagust, W. J.; Valk, P. E.

    1989-09-01

    One of the unexpected fruits of basic physics research and the computer revolution is the noninvasive imaging power available to today's physician. Technologies that were strictly the province of research scientists only a decade or two ago now serve as the foundations for such standard diagnostic tools as x-ray computer tomography (CT), magnetic resonance imaging (MRI), magnetic resonance spectroscopy (MRS), ultrasound, single photon emission computed tomography (SPECT), and positron emission tomography (PET). Furthermore, prompted by the needs of both the practicing physician and the clinical researcher, efforts to improve these technologies continue. This booklet endeavors to describe the advantages of achieving high resolution in PET imaging.

  6. Refinement procedure for the image alignment in high-resolution electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Houben, L., E-mail: l.houben@fz-juelich.de [Peter Gruenberg Institute and Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons (ER-C), Research Centre Juelich, 52425 Juelich (Germany); Bar Sadan, M. [Peter Gruenberg Institute and Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons (ER-C), Research Centre Juelich, 52425 Juelich (Germany)

    2011-08-15

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. -- Highlights: {yields} Alignment procedure for electron tomography based on iterative tomogram contrast optimisation. {yields} Marker-free, independent of object, little user interaction. {yields} Accuracy competitive with fiducial marker methods and suited for high-resolution tomography.

  7. Lipoid pneumonia in adults: findings on high-resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. of Radiology]. E-mail: edmarchiori@gmail.com; Zanetti, Glaucia [Faculdade de Medicina de Petropolis, RJ (Brazil); Escuissato, Dante L. [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil); Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil); Araujo Neto, Cesar [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil); Nobre, Luiz Felipe [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil); Irion, Klaus L. [The Cardiothoracic Centre NHS Trust, Liverpool (United Kingdom); Rodrigues, Rosana [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Hospital Universitario Clementino Fraga Filho (HUCFF); Mancano, Alexandre Dias [Hospital Regional de Taguatinga, Brasilia, DF (Brazil); Capone, Domenico [Universidade Estadual do Rio de Janeiro (UERJ), RJ (Brazil); Fialho, Suzane Mansur [Centro Nuclear da Guanabara, Rio de Janeiro, RJ (Brazil); Souza, Carolina Althoff [University of Ottawa (Canada)

    2007-09-15

    Objective: The present study was aimed at describing the findings on high-resolution computed tomography in patients with exogenous lipoid pneumonia secondary to mineral oil aspiration. Materials and methods: Eight adult patients - four men and four women - with mean age of 69.4 years were studied. All of the patients were users of mineral oil for treating intestinal constipation. High-resolution computed tomography studies of these patients were blindly evaluated by two radiologists. Results: Air-space consolidation with areas of fat density and crazy paving pattern were the most frequent findings. The lesions were bilateral in six cases and unilateral in two. Conclusion: Air-space consolidation with areas of fat density, associated with a clinical history of mineral oil ingestion virtually indicates a diagnosis of exogenous lipoid pneumonia. (author)

  8. High resolution computed tomography of the inferior alveolar and lingual nerves

    Energy Technology Data Exchange (ETDEWEB)

    Feifel, H. (Dept. of Oral and Maxillofacial Surgery, Katharinenhospital, Stuttgart (Germany)); Riediger, D. (Dept. of Oral and Maxillofacial Surgery, Katharinenhospital, Stuttgart (Germany)); Gustorf-Aeckerle, R. (Dept. of Neuroradiology, Katharinenhospital, Stuttgart (Germany))

    1994-04-01

    Coronal and axial high resolution computed tomography of the mandible extends facilities in dentoalveolar surgery. Preoperatively the relationship between the mandibular canal and the roots of deeply displaced third molars can be determined precisely. After surgical removal of lower wisdom teeth iatrogenic defects of the lingual cortical bone can be detected. The additional information obtained when compared with conventional radiographs is demonstrated in case descriptions. Indications for this technique, radiation exposure and implications for surgery are discussed. (orig.)

  9. Single-Photon Emission Computerized Tomography (SPECT in Neuropsychiatry: A Review

    Directory of Open Access Journals (Sweden)

    B. K. Puri

    1992-01-01

    Full Text Available Cranial single-photon emission computerized tomography (SPECT or SPET can now give regional cerebral blood flow images with a resolution approaching that of positron emission tomography (PET. In this paper, the use of high resolution SPECT neuroimaging in neuropsychiatric disorders, including Alzheimer's disease, multi-infarct dementia, Pick's disease, progressive supranuclear palsy, Korsakoff's psychosis, Creutzfeld-Jakob disease, Parkinson's disease, Huntington's disease, schizophrenia, mood disorders, obsessive–compulsive disorder, HIV infection and AIDS is reviewed. Finally, further potential research and clinical uses, based on ligand studies, are outlined.

  10. Significance of computerized tomography and nasal cytology in the ...

    African Journals Online (AJOL)

    Significance of computerized tomography and nasal cytology in the diagnosis of rhinosinusitis among asthmatic children. Karima Abdel Khalik, Laila AG Hegazy, Hassan A Wahba, Laila A Abdurrahman, Sahar SA Zaki ...

  11. Radation distribution in head & thorax computerized tomography

    Directory of Open Access Journals (Sweden)

    Mohammad Mahdavi

    2014-05-01

    Full Text Available Background: Determination of the exposure levels in the computerized tomography (CT practices is necessary to define the respected national reference levels, quality control of CT centers and the risk assessment for radiation induced cancers. Material and Methods: On the basis of this necessity, the radiation exposure distribution due to common CT practices has been investigated at Razi Hospital CT center in Rasht using tissue-equivalent phantoms and the thermoluminescent dosimeters (TLD. The Head and Thorax phantoms were used with the standard dimensions incorporating holes at the center and edges for TLD placement. Dosimetry was carried out using LiF Mg, Cu, P small chips due to their relatively tissue equivalence, high sensitivity convenient annealing procedure and the non-complex glow curve. Results: Results showed that CTDI for Head is 52.85 mGy and for Body is 68.15mGy. CTDLW for Head is 13.67 mGy and for Body is 16.94mGy . Conclusion: In comparison with other radiographical procedures, patient absorbed doses in CT imaging are usually very high. Content of dose is increased by increase of mAs.

  12. Study on forefoot by computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Machida, Eiichi (Nihon Univ., Tokyo. School of Medicine)

    1983-10-01

    Computerized tomography (CT) was used to study coronary sections of the forefoot in both normal and abnormal human feet. CT images of the transverse arches at the metatarsal head, middle and base of the shaft were classified into five patterns. In the pattern most commonly found in normal feet, the second metatarsus appeared elevated above the other metatarsal bones at all points, and there was a gradual and even reduction in elevation from the second to the fifth metatarsal. In cases of hallux valgus, however, a variety of deformities were noted in the arc of the second to fifth metatarsals, particularly at the head. The rotation of the first metatarsus and shift of the sesamoids were measured from CT images at the head of the first metatarsus. In hallux valgus, both the rotation and the sesamoid shift appeared to have a wider angle than in the case of normal feet. In normal feet, the differences between the rotation of the first metatarsus and shift of the sesamoids were relatively small, whereas in hallux valgus there was a much greater degree of variation. Furthermore, while normal feet the variation in rotation of the first metatarsus and sesamoid shift both tended to be either great or small, in hallux valgus a large degree of sesamoid shift was sometimes found in combination with a small degree of rotation of the first metatarsus.

  13. High-resolution PET (positron emission tomography) for medical science studies

    Energy Technology Data Exchange (ETDEWEB)

    Budinger, T.F.; Derenzo, S.E.; Huesman, R.H.; Jagust, W.J.; Valk, P.E. (Lawrence Berkeley Lab., CA (USA))

    1989-09-01

    One of the unexpected fruits of basic physics research and the computer revolution is the noninvasive imaging power available to today's physician. Technologies that were strictly the province of research scientists only a decade or two ago now serve as the foundations for such standard diagnostic tools as x-ray computer tomography (CT), magnetic resonance imaging (MRI), magnetic resonance spectroscopy (MRS), ultrasound, single photon emission computed tomography (SPECT), and positron emission tomography (PET). Furthermore, prompted by the needs of both the practicing physician and the clinical researcher, efforts to improve these technologies continue. This booklet endeavors to describe the advantages of achieving high resolution in PET imaging. 6 refs., 21 figs.

  14. Compact high-resolution gamma-ray computed tomography system for multiphase flow studies.

    Science.gov (United States)

    Bieberle, A; Nehring, H; Berger, R; Arlit, M; Härting, H-U; Schubert, M; Hampel, U

    2013-03-01

    In this paper, a compact high-resolution gamma-ray Computed Tomography (CompaCT) measurement system for multiphase flow studies and tomographic imaging of technical objects is presented. Its compact and robust design makes it particularly suitable for studies on industrial facilities and outdoor applications. Special care has been given to thermal ruggedness, shock resistance, and radiation protection. Main components of the system are a collimated (137)Cs isotopic source, a thermally stabilised modular high-resolution gamma-ray detector arc with 112 scintillation detector elements, and a transportable rotary unit. The CompaCT allows full CT scans of objects with a diameter of up to 130 mm and can be operated with any tilting angle from 0° (horizontal) to 90° (vertical).

  15. A study with high resolution computed tomography of bone destruction in cholesteatoma

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Shigeru; Yamaso, Tatsuya; Higo, Ryusaburo (Kameda General Hospital, Kamogawa, Chiba (Japan)); Senba, Tetsuo; Iinuma, Yoshitaka

    1992-07-01

    The modes and incidences of bone destruction in the middle ear cholesteatoma were evaluated by high resolution computed tomography, comparing with chronic otitis media with central perforation (COM) as control. The head of the malleus, the body and long process of the incus were more markedly destroyed in cholesteatoma than in COM with statistical significance. With the further extension of cholesteatoma into the antrum, the tegmen of the aditus ad antrum, the lateral semicircular canal, the handle of the malleus and the Korner's septum were involved in bone destruction. (author).

  16. Pulmonary complications of crack cocaine use: high-resolution computed tomography of the chest

    Energy Technology Data Exchange (ETDEWEB)

    Mancano, Alexandre [Taguatinga Regional Hospital, Taguatinga, DF (Brazil). Medical Residency in Radiology and Diagnostic Imaging; Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. of Radiology]. E-mail: edmarchiori@bol.com.br; Zanetti, Glaucia [Faculdade de Medicina de Petropolis (FMP), RJ (Brazil). School of Medicine; Escuissato, Dante Luiz [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Radiology; Duarte, Beatriz Cunha; Apolinario, Lourenco de Araujo [Radiologia Anchieta, Taguatinga, DF (Brazil)

    2008-05-15

    Here, we report high-resolution computed tomography (HRCT) findings in a patient who developed sudden hemoptysis, dyspnea and chest pain after smoking crack cocaine. Chest X-rays showed consolidations, primarily in the upper lobes, and HRCT scans showed ground glass attenuation opacities, consolidations and air-space nodules. A follow-up CT, after drug use discontinuation and administration of corticosteroids, showed partial resolution of pulmonary lesions and the appearance of cavitations. Clinical, imaging and laboratory findings led to a diagnosis of 'crack lung'. (author)

  17. Phenotyping of chronic obstructive pulmonary disease using the modified Bhalla scoring system for high-resolution computed tomography

    National Research Council Canada - National Science Library

    Tulek, Baykal; Kivrak, Ali Sami; Ozbek, Seda; Kanat, Fikret; Suerdem, Mecit

    2013-01-01

    .... To characterize the phenotypes of COPD according to high-resolution computed tomography (HRCT) findings; and to correlate HRCT scores obtained using the modified Bhalla scoring system with clinical and physiological indicators of systemic inflammation...

  18. Comparison of three-dimensional optical coherence tomography and high resolution photography for art conservation studies.

    Science.gov (United States)

    Adler, Desmond C; Stenger, Jens; Gorczynska, Iwona; Lie, Henry; Hensick, Teri; Spronk, Ron; Wolohojian, Stephan; Khandekar, Narayan; Jiang, James Y; Barry, Scott; Cable, Alex E; Huber, Robert; Fujimoto, James G

    2007-11-26

    Gold punchwork and underdrawing in Renaissance panel paintings are analyzed using both three-dimensional swept source / Fourier domain optical coherence tomography (3D-OCT) and high resolution digital photography. 3D-OCT can generate en face images with micrometer-scale resolutions at arbitrary sectioning depths, rejecting out-of-plane light by coherence gating. Therefore 3D-OCT is well suited for analyzing artwork where a surface layer obscures details of interest. 3D-OCT also enables cross-sectional imaging and quantitative measurement of 3D features such as punch depth, which is beneficial for analyzing the tools and techniques used to create works of art. High volumetric imaging speeds are enabled by the use of a Fourier domain mode locked (FDML) laser as the 3D-OCT light source. High resolution infrared (IR) digital photography is shown to be particularly useful for the analysis of underdrawing, where the materials used for the underdrawing and paint layers have significantly different IR absrption properties. In general, 3D-OCT provides a more flexible and comprehensive analysis of artwork than high resolution photography, but also requires more complex instrumentation and data analysis.

  19. Diagnosis of ocular surface lesions using ultra-high-resolution optical coherence tomography.

    Science.gov (United States)

    Shousha, Mohamed Abou; Karp, Carol L; Canto, Ana Paula; Hodson, Kelly; Oellers, Patrick; Kao, Andrew A; Bielory, Brett; Matthews, Jared; Dubovy, Sander R; Perez, Victor L; Wang, Jianhua

    2013-05-01

    To assess the use of ultra-high-resolution (UHR) optical coherence tomography (OCT) in the diagnosis of ocular surface lesions. Prospective, noncomparative, interventional case series. Fifty-four eyes of 53 consecutive patients with biopsy-proven ocular surface lesions: 8 primary acquired melanosis lesions, 5 amelanotic melanoma lesions, 2 nevi, 19 ocular surface squamous neoplasia lesions, 1 histiocytosis lesion, 6 conjunctival lymphoma lesions, 2 conjunctival amyloidosis lesions, and 11 pterygia lesions. Ultra-high-resolution OCT imaging of the ocular surface lesions. Clinical course and photographs, UHR OCT image, and histopathologic findings. Ultra-high-resolution OCT images of all examined ocular surface lesions showed close correlation with the obtained histopathologic specimens. When clinical differential diagnosis of ocular surface lesions was broad, UHR OCT images provided optical signs indicating a more specific diagnosis and management. In cases of amelanotic melanoma, conjunctival amyloidosis, and primary histiocytosis and in 1 case of ocular surface squamous neoplasia, UHR OCT was instrumental in guiding the diagnosis. In those cases, UHR OCT suggested that the presumed clinical diagnosis was incorrect and favored a diagnosis that later was confirmed by histopathologic examination. Correlations between UHR OCT and histopathologic findings confirm that UHR OCT is an adjunctive diagnostic method that can provide a noninvasive means to help guide diagnosis and management of ocular surface lesions. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. In situ visualization of tears on contact lens using ultra high resolution optical coherence tomography.

    Science.gov (United States)

    Wang, Jianhua; Jiao, Shuliang; Ruggeri, Marco; Shousha, Mohamed Abou; Shousha, Mohammed Abou; Chen, Qi

    2009-03-01

    To demonstrate the capability of directly visualizing the tear film on contact lenses using optical coherence tomography (OCT). Six eyes of three healthy subjects wearing PureVision and ACUVUE Advance soft and Boston RGP hard contact lenses were imaged with a custom built, high speed, ultra-high resolution spectral domain optical coherence tomograph. Refresh Liquigel was used to demonstrate the effect of artificial tears on the tear film. Ultra high resolution images of the pre- and post-lens films were directly visualized when each lens was inserted onto the eye. After the instillation of artificial tears during lens wear, the tear film was thicker. The post-lens tear film underneath the lens edge was clearly shown. Interactions between the lens edges and the ocular surface were obtained for each of the lens types and base curves. With a contrast enhancement agent, tear menisci on the contact lenses around the upper and lower eyelids were highlighted. With hard contact lenses, the tear film was visualized clearly and changed after a blink when the lens was pulled up by the lid. Ultra-high resolution OCT is a potentially promising technique for imaging tears around contact lenses. This successful demonstration of in situ post-lens tear film imaging suggests that OCT could open a new era in studying tear dynamics during contact lens wear. The novel method may lead to new ways of evaluating contact lens fitting.

  1. Development of sealed sample containers and high resolution micro-tomography

    Energy Technology Data Exchange (ETDEWEB)

    Uesugi, Kentaro, E-mail: ueken@spring8.or.jp; Takeuchi, Akihisa; Suzuki, Yoshio [Japan synchrotron radiation research institute, JASRI/SPring-8 Kouto 1-1-1, Sayo, Hyogo 679-5198 Japan (Japan); Uesugi, Masayuki [Japan Aerospace Exploration Agency (ISAS/JAXA), Sagamihara, Kanagawa 252-5210 (Japan); Hamada, Hiroshi [NTT Advanced technology Corporation, Atsugi, Kanagawa 243-0124 (Japan)

    2016-01-28

    A sample container and a high resolution micro-tomography system have been developed at BL47XU at SPring-8. The container is made of a SiN membrane in a shape of truncated pyramid, which makes it possible to exclude oxygen and moisture in the air. The sample rotation stage for tomography is set downward to keep the sample in the container without any glue. The spatial resolution and field of view are 300 nm and 110 μm using a Fresnel zone plate objective with an outermost zone width of 100 nm at 8 keV, respectively. The scan time is about 20 minutes for 1800 projections. A 3-D image of an asteroid particle was successfully obtained without adhesive and contamination.

  2. Primary graft dysfunction; possible evaluation by high resolution computed tomography, and suggestions for a scoring system

    DEFF Research Database (Denmark)

    Belmaati, Esther; Jensen, Claus; Kofoed, Klaus F

    2009-01-01

    We have reviewed and discussed current knowledge on existing scoring systems regarding high resolution computed tomography (HRCT) images for the assessment of primary graft dysfunction (PGD) after lung transplantation. Adult respiratory distress syndrome (ARDS) has been more widely studied...... performed on patients with cystic fibrosis (CF). Sensitivity of HRCT for the detection of parenchymal changes is superior to other imaging methods. High levels of reproducibility are achievable amongst observers who score HRCT lung images. Development of standardized criteria that specify the inclusion......, and reproducibility of these systems were discussed. Lastly, the future perspectives for 64-multi-slice computed tomography (MSCT) in relation to PGD were discussed. Few studies on scoring systems of lung tissue by HRCT in ARDS patients and idiopathic pulmonary fibrosis (IPF) patients were found. Most studies were...

  3. Imaging the slab structure in the Alpine region by high-resolution P-wave tomography

    Science.gov (United States)

    Guillot, Stéphane; Zhao, Liang; Paul, Anne; Malusà, Marco G.; Xu, Xiaobing; Zheng, Tianyu; Solarino, stefano; Schwartz, Stéphane; Dumont, Thierry; Salimbeni, Simone; Aubert, Coralie; Pondrelli, Silvia; Wang, Qingchen; Zhu, Rixiang

    2017-04-01

    Based upon a finite-frequency inversion of traveltimes, we computed a new high-resolution tomography model using P-wave data from 527 broadband seismic stations, both from permanent networks and temporary experiments (Zhao et al., 2016). This model provides an improved image of the slab structure in the Alpine region, and fundamental pin-points for the analysis of Cenozoic magmatism, (U)HP metamorphism and Alpine topography. Our results document the lateral continuity of the European slab from the Western to the Central Alps, and the down-dip slab continuity beneath the Central Alps, ruling out the hypothesis of slab breakoff to explain Cenozoic Alpine magmatism. A low velocity anomaly is observed in the upper mantle beneath the core of the Western Alps, pointing to dynamic topography effects (Malusà et al., this meeting). A NE-dipping Adriatic slab, consistent with Dinaric subduction, is possibly observed beneath the Eastern Alps, whereas the laterally continuous Adriatic slab of the Northern Apennines shows major gaps at the boundary with the Southern Apennines, and becomes near vertical in the Alps-Apennines transition zone. Tear faults accommodating opposite-dipping subductions during Alpine convergence may represent reactivated lithospheric faults inherited from Tethyan extension. Our results suggest that the interpretations of previous tomography results that include successive slab breakoffs along the Alpine-Zagros-Himalaya orogenic belt might be proficiently reconsidered. Malusà M.G. et alii (2017) On the potential asthenospheric linkage between Apenninic slab rollback and Alpine topographic uplift: insights from P wave tomography and seismic anisotropy analysis. EGU 2017. Zhao L. et alii (2016), Continuity of the Alpine slab unraveled by high-resolution P wave tomography. J. Geophys. Res., doi:10.1002/2016JB013310.

  4. Clinical, High Resolution Computed Tomography and Pulmonary Function in Sulphur Mustard Victims

    Directory of Open Access Journals (Sweden)

    Javad Moghimi

    2012-09-01

    Full Text Available We aimed to evaluate clinical, high resolution computed tomography (HRCT and pulmonary function test (PFT findings after 18-23 years of exposure in veterans of sulphur mustard (SM exposure. We performed a cross-sectional study of 106 patients. Inclusion criteria were 1: documented exposure to SM as confirmed by toxicological analysis of their urine and vesicular fluid after exposure 2: single exposure to SM that cause skin blisters and subsequent transient or permanent sequel. Cigarette smoking and pre-exposure lung diseases were of exclusion criteria. After taking history and thorough respiratory examination, patients underwent high resolution computed tomography and spirometry. Clinical diagnoses were made considering the findings. More than 85% of the patients were complaining of dyspnea and cough. Obstructive pattern (56.6% was main finding in spirometry followed by restrictive and normal patterns. HRCT revealed air trapping (65.09% and mosaic parenchymal attenuation patterns (58.49% as most common results. Established diagnoses mainly were chronic obstructive pulmonary disease (COPD (54.71%, bronchiolitis obliterans (27.35% and asthmatic bronchitis (8.49%. There were not any significant association between the clinical findings and results of PFT and HRCT imaging and also between PFT and HRCT findings (P-values were more than 0.05. Considering debilitating and progressive nature of the respiratory complications of SM exposure, attempts are needed for appropriate diagnosis and treatment.

  5. Quantitative 3D high resolution transmission ultrasound tomography: creating clinically relevant images (Conference Presentation)

    Science.gov (United States)

    Wiskin, James; Klock, John; Iuanow, Elaine; Borup, Dave T.; Terry, Robin; Malik, Bilal H.; Lenox, Mark

    2017-03-01

    There has been a great deal of research into ultrasound tomography for breast imaging over the past 35 years. Few successful attempts have been made to reconstruct high-resolution images using transmission ultrasound. To this end, advances have been made in 2D and 3D algorithms that utilize either time of arrival or full wave data to reconstruct images with high spatial and contrast resolution suitable for clinical interpretation. The highest resolution and quantitative accuracy result from inverse scattering applied to full wave data in 3D. However, this has been prohibitively computationally expensive, meaning that full inverse scattering ultrasound tomography has not been considered clinically viable. Here we show the results of applying a nonlinear inverse scattering algorithm to 3D data in a clinically useful time frame. This method yields Quantitative Transmission (QT) ultrasound images with high spatial and contrast resolution. We reconstruct sound speeds for various 2D and 3D phantoms and verify these values with independent measurements. The data are fully 3D as is the reconstruction algorithm, with no 2D approximations. We show that 2D reconstruction algorithms can introduce artifacts into the QT breast image which are avoided by using a full 3D algorithm and data. We show high resolution gross and microscopic anatomic correlations comparing cadaveric breast QT images with MRI to establish imaging capability and accuracy. Finally, we show reconstructions of data from volunteers, as well as an objective visual grading analysis to confirm clinical imaging capability and accuracy.

  6. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brun, E., E-mail: emmanuel.brun@esrf.fr [European Synchrotron Radiation Facility (ESRF), Grenoble 380000, France and Department of Physics, Ludwig-Maximilians University, Garching 85748 (Germany); Grandl, S.; Sztrókay-Gaul, A.; Gasilov, S. [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Barbone, G. [Department of Physics, Harvard University, Cambridge, Massachusetts 02138 (United States); Mittone, A.; Coan, P. [Department of Physics, Ludwig-Maximilians University, Garching 85748, Germany and Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Bravin, A. [European Synchrotron Radiation Facility (ESRF), Grenoble 380000 (France)

    2014-11-01

    Purpose: Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. Methods: The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure’s possible applications. Results: A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. Conclusions: The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  7. Brochopulmonary dysplasia: New high resolution computed tomography scorting system and correlation between the high resolution computed tomography score and clinical severity

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sumi; Kim, Woo Sun; Cheon, Jung Eun; Kim, Han Suk; Lee, Whal; Jung, Ah Young; Kim, In One; Choi, Jung Hwan [Seoul National University College of Medicine, Seoul (KR)

    2013-04-15

    To develop an high resolution computed tomography (HRCT) scoring system for the assessment of bronchopulmonary dysplasia (BPD) and determine its usefulness as compared with the chest radiographic score. Forty-two very low-birth-weight preterm infants with BPD (25 male, 17 female) were prospectively evaluated with HRCT performed at the mean age of 39.1-week postmenstrual age. Clinical severity of BPD was categorized as mild, moderate or severe. The HRCT score (0-36) of each patient was the sum of the number of bronchopulmonary segments with 1) hyperaeration and 2) parenchymal lesions (linear lesions, segmental atelectasis, consolidation and architectural distortion), respectively. We compared the HRCT scores with the chest radiographic scores (the Toce system) in terms of correlation with clinical severity. The HRCT score had good interobserver (r = 0.969, p < 0.001) and intraobserver (r = 0.986, p < 0.001) reproducibility. The HRCT score showed better correlation (r = 0.646, p < 0.001) with the clinical severity of BPD than the chest radiographic score (r = 0.410, p = 0.007). The hyperaeration score showed better correlation (r = 0.738, p < 0.001) with the clinical severity of BPD than the parenchymal score (r = 0.523, p < 0.001). We have developed a new HRCT scoring system for BPD based on the quantitative evaluation of pulmonary abnormalities of BPD consisting of the hyperaeration score and the parenchymal score. The HRCT score shows better correlation with the clinical severity of BPD than the radiographic score.

  8. High Resolution X-ray Computed Tomography: An Emerging Tool for Small Animal Cancer Research

    Directory of Open Access Journals (Sweden)

    Michael J. Paulus

    2000-01-01

    Full Text Available Dedicated high-resolution small animal imaging systems have recently emerged as important new tools for cancer research. These new imaging systems permit researchers to noninvasively screen animals for mutations or pathologies and to monitor disease progression and response to therapy. One imaging modality, X-ray microcomputed tomography (microCT shows promise as a cost-effective means for detecting and characterizing soft-tissue structures, skeletal abnormalities, and tumors in live animals. MicroCT systems provide highresolution images (typically 50 microns or less, rapid data acquisition (typically 5 to 30 minutes, excellent sensitivity to skeletal tissue and good sensitivity to soft tissue, particularly when contrast-enhancing media are employed. The development of microCT technology for small animal imaging is reviewed, and key considerations for designing small animal microCT imaging protocols are summarized. Recent studies on mouse prostate, lung and bone tumor models are overviewed.

  9. Compressive Sensing in High-resolution 3D SAR Tomography of Urban Scenarios

    Directory of Open Access Journals (Sweden)

    Liao Ming-sheng

    2015-04-01

    Full Text Available In modern high resolution SAR data, due to the intrinsic side-looking geometry of SAR sensors, layover and foreshortening issues inevitably arise, especially in dense urban areas. SAR tomography provides a new way of overcoming these problems by exploiting the back-scattering property for each pixel. However, traditional non-parametric spectral estimators, e.g. Truncated Singular Value Decomposition (TSVD, are limited by their poor elevation resolution, which is not comparable to the azimuth and slant-range resolution. In this paper, the Compressive Sensing (CS approach using Basis Pursuit (BP and TWo-step Iterative Shrinkage/Thresholding (TWIST are introduced. Experimental studies with real spotlight-mode TerraSAR-X dataset are carried out using both BP and TWIST, to demonstrate the merits of compressive sensing approaches in terms of robustness, computational efficiency, and super-resolution capability.

  10. Ultra-high resolution optical coherence tomography for encapsulation quality inspection

    KAUST Repository

    Czajkowski, Jakub

    2011-08-28

    We present the application of ultra-high resolution optical coherence tomography (UHR-OCT) in evaluation of thin, protective films used in printed electronics. Two types of sample were investigated: microscopy glass and organic field effect transistor (OFET) structure. Samples were coated with thin (1-3 μm) layer of parylene C polymer. Measurements were done using experimental UHR-OCT device based on a Kerr-lens mode locked Ti: sapphire femtosecond laser, photonic crystal fibre and modified, free-space Michelson interferometer. Submicron resolution offered by the UHR-OCT system applied in the study enables registration of both interfaces of the thin encapsulation layer. Complete, volumetric characterisation of protective layers is presented, demonstrating possibility to use OCT for encapsulation quality inspection. © Springer-Verlag 2011.

  11. Applied x-ray computed tomography with high resolution in paleontology using laboratory and synchrotron sources

    Science.gov (United States)

    Bidola, Pidassa; Pacheco, Mirian L. A. F.; Stockmar, Marco K.; Achterhold, Klaus; Pfeiffer, Franz; Beckmann, Felix; Tafforeau, Paul; Herzen, Julia

    2014-09-01

    X-ray computed tomography (CT) has become an established technique in the biomedical imaging or materials science research. Its ability to non-destructively provide high-resolution images of samples makes it attractive for diverse fields of research especially the paleontology. Exceptionally, the Precambrian is a geological time of rocks deposition containing several fossilized early animals, which still need to be investigated in order to predict the origin and evolution of early life. Corumbella werneri is one of those fossils skeletonized in Corumbá (Brazil). Here, we present a study on selected specimens of Corumbella werneri using absorption-based contrast imaging at diverse tomographic setups. We investigated the potential of conventional laboratory-based device and synchrotron radiation sources to visualize internal structures of the fossils. The obtained results are discussed as well as the encountered limitations of those setups.

  12. Phase contrast enhanced high resolution X-ray imaging and tomography of soft tissue

    Energy Technology Data Exchange (ETDEWEB)

    Jakubek, Jan [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Granja, Carlos [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic)]. E-mail: carlos.granja@utef.cvut.cz; Dammer, Jiri [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Hanus, Robert [Institute of Organic Chemistry and Biochemistry, Academy of Sciences, CZ-166 10 Prague 6 (Czech Republic); Holy, Tomas [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Pospisil, Stanislav [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Tykva, Richard [Institute of Organic Chemistry and Biochemistry, Academy of Sciences, CZ-166 10 Prague 6 (Czech Republic); Uher, Josef [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Vykydal, Zdenek [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic)

    2007-02-01

    A tabletop system for digital high resolution and high sensitivity X-ray micro-radiography has been developed for small-animal and soft-tissue imaging. The system is based on a micro-focus X-ray tube and the semiconductor hybrid position sensitive Medipix2 pixel detector. Transmission radiography imaging, conventionally based only on absorption, is enhanced by exploiting phase-shift effects induced in the X-ray beam traversing the sample. Phase contrast imaging is realized by object edge enhancement. DAQ is done by a novel fully integrated USB-based readout with online image generation. Improved signal reconstruction techniques make use of advanced statistical data analysis, enhanced beam hardening correction and direct thickness calibration of individual pixels. 2D and 3D micro-tomography images of several biological samples demonstrate the applicability of the system for biological and medical purposes including in-vivo and time dependent physiological studies in the life sciences.

  13. High-resolution computed tomography of cholesteatoma of the middle ear. CT, otological, and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Kiyoshi; Fukusumi, Akio; Okudera, Toshio; Kato, Toshihiko; Soda, Toyoji

    1988-08-01

    The high-resolution computed tomography (CT) appearances of 72 consecutive cases (92 ears) of chronic otomastoiditis were reviewed. The cholesteatomas were verified surgically and/or otologically in 35 of these 92 ears. Discussion was made with special emphasis on the differential diagnosis of cholesteatoma of the middle ear from the non-cholesteatoma otitis media. The CT findings suggestive of cholesteatoma were as follows: the definitive findings was of a soft-tissue opacity filling Purssak's space, with a medial displacement of the malleus and the incus; the possible findings were 1) a bony erosion of the wall of the middle ear cavity, 2) a partial or complete disappearance of the malleus and/or the incus, and 3) an opacification of Purssak's space and the superomedial aspect of the external auditory meatus.

  14. High-resolution computed tomography findings in eight patients with hantavirus pulmonary syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Diego de Lacerda; Hochhegger, Bruno; Souza Junior, Arthur Soares; Zanetti, Glaucia; Escuissato, Dante Luiz; Meirelles, Gustavo de Souza Portes; Funari, Marcelo Buarque de Gusmao; Marchiori, Edson, E-mail: edmarchiori@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Santa Casa de Porto Alegre, Porto Alegre, RS (Brazil); Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil); Ultra X, Sao Jose do Rio Preto, SP (Brazil); Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil); Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); Grupo Fleury, Sao Paulo, SP (Brazil); Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Faculdade de Medicina

    2017-05-15

    Objective: The purpose of this study was to describe the high-resolution computed tomography (HRCT) findings in patients with hantavirus pulmonary syndrome (HPS). Materials and Methods: We retrospectively reviewed HRCT findings from eight cases of HPS. All patients were men, aged 19-70 (mean, 41.7) years. Diagnoses were established by serological test (enzyme-linked immunosorbent assay) in all patients. Two chest radiologists analyzed the images and reached decisions by consensus. Results: The predominant HRCT findings were ground-glass opacities (GGOs) and smooth inter- and intralobular septal thickening, found in all eight cases; however, the crazy-paving pattern was found in only three cases. Pleural effusion and peribronchovascular thickening were observed in five patients. The abnormalities were bilateral in all patients. Conclusion: The predominant HRCT findings in patients with HPS were GGOs and smooth inter- and intralobular septal thickening, which probably correlate with the histopathologic findings of pulmonary edema. (author)

  15. Ultra-high resolution Fourier domain optical coherence tomography for old master paintings.

    Science.gov (United States)

    Cheung, C S; Spring, M; Liang, H

    2015-04-20

    In the last 10 years, Optical Coherence Tomography (OCT) has been successfully applied to art conservation, history and archaeology. OCT has the potential to become a routine non-invasive tool in museums allowing cross-section imaging anywhere on an intact object where there are no other methods of obtaining subsurface information. While current commercial OCTs have shown potential in this field, they are still limited in depth resolution (> 4 μm in paint and varnish) compared to conventional microscopic examination of sampled paint cross-sections (~1 μm). An ultra-high resolution fiber-based Fourier domain optical coherence tomography system with a constant axial resolution of 1.2 μm in varnish or paint throughout a depth range of 1.5 mm has been developed. While Fourier domain OCT of similar resolution has been demonstrated recently, the sensitivity roll-off of some of these systems are still significant. In contrast, this current system achieved a sensitivity roll-off that is less than 2 dB over a 1.2 mm depth range with an incident power of ~1 mW on the sample. The high resolution and sensitivity of the system makes it convenient to image thin varnish and glaze layers with unprecedented contrast. The non-invasive 'virtual' cross-section images obtained with the system show the thin varnish layers with similar resolution in the depth direction but superior clarity in the layer interfaces when compared with conventional optical microscope images of actual paint sample cross-sections obtained micro-destructively.

  16. Computerized tomography and angiography - competing processes in liver diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Wunschik, F.; Luetgemeier, J.; Hoerst, M.

    1981-02-01

    In the diagnostics of liver diseases, computerized tomography is a valuable method. It is particularly superior to angiography in detecting cysts, parasitosis and abscesses. Angiography however is better for known solid tumours regarding differencial diagnosis. Both methods supplement each other in the tumour and bile ducts diagnostics.

  17. Measurement of ciliary beat frequency using ultra-high resolution optical coherence tomography

    Science.gov (United States)

    Chen, Jason J.; Jing, Joseph C.; Su, Erica; Badger, Christopher; Coughlan, Carolyn A.; Chen, Zhongping; Wong, Brian J. F.

    2016-02-01

    Ciliated epithelial cells populate up to 80% of the surface area of the human airway and are responsible for mucociliary transport, which is the key protective mechanism that provides the first line of defense in the respiratory tract. Cilia beat in a rhythmic pattern and may be easily affected by allergens, pollutants, and pathogens, altering ciliary beat frequency (CBF) subsequently. Diseases including cystic fibrosis, chronic obstructive pulmonary disease, and primary ciliary dyskinesia may also decrease CBF. CBF is therefore a critical component of respiratory health. The current clinical method of measuring CBF is phase-contrast microscopy, which involves a tissue biopsy obtained via brushing of the nasal cavity. While this method is minimally invasive, the tissue sample must be oriented to display its profile view, making the visualization of a single layer of cilia challenging. In addition, the conventional method requires subjective analysis of CBF, e.g., manually counting by visual inspection. On the contrary, optical coherence tomography (OCT) has been used to study the retina in ophthalmology as well as vasculature in cardiology, and offers higher resolution than conventional computed tomography and magnetic resonance imaging. Based on this technology, our lab specifically developed an ultra-high resolution OCT system to image the microstructure of the ciliated epithelial cells. Doppler analysis was also performed to determine CBF. Lastly, we also developed a program that utilizes fast Fourier transform to determine CBF under phase-contrast microscopy, providing a more objective method compared to the current method.

  18. High-resolution computed tomography findings in pulmonary paracoccidioidomycosis; Paracoccidioidomicose pulmonar - aspectos na tomografia computadorizada de alta resolucao

    Energy Technology Data Exchange (ETDEWEB)

    Muniz, Maria Angelica Soares; Magnago, Marcelo; Moreira, Luiza Beatriz Melo [Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil). Servico de Radiologia; Marchiori, Edson; Almeida Junior, Jose Guiomar de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@zipmail.com.br

    2002-06-01

    Pulmonary disease in paracoccidioidomycosis is very common and in some cases can be the sole manifestation of the disease. We studied the findings observed in 30 patients with pulmonary paracoccidioidomycosis submitted to high-resolution computed tomography in order to determine the most frequent findings, presentation patterns and distribution of paracoccidioidomycosis lesions in the lungs. The most frequent findings observed in high-resolution computed tomography were: interlobular septal thickening (96.7%), ground-glass opacities (66.7%), nodules (60%), irregular air-space enlargement (56.7%), bronchial wall thickening (46.7%), pleural thickening (36.7%), tracheal dilatation (33.3%), architectural distortion (30%), air-space consolidation (30%), parenchymal bands (23.3%), intralobular reticulate (13.3%) and hilar interstitial thickening (10%). Chest X-ray allow limited evaluation of diffuse pulmonary diseases, and hence high-resolution computed tomography is an essential method for studying patients with pulmonary paracoccidioidomycosis. (author)

  19. Morphological analysis of the vestibular aqueduct by computerized tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Sergio Ricardo [Morphology and Genetics Department, Sao Paulo Federal University-Paulista Medical School, Disciplina de Anatomia Descritiva e Topografica, Rua Botucatu, 740-Edificio Leitao da Cunha, CEP 04023-900, Vila Clementino, Sao Paulo (Brazil)]. E-mail: sergioanat.morf@epm.br; Smith, Ricardo Luiz [Morphology and Genetics Department, Sao Paulo Federal University-Paulista Medical School, Disciplina de Anatomia Descritiva e Topografica, Rua Botucatu, 740-Edificio Leitao da Cunha, CEP 04023-900, Vila Clementino, Sao Paulo (Brazil); Isotani, Sadao [Institute of Physics, University of Sao Paulo, Sao Paulo (Brazil); Alonso, Luis Garcia [Morphology and Genetics Department, Sao Paulo Federal University-Paulista Medical School, Disciplina de Anatomia Descritiva e Topografica, Rua Botucatu, 740-Edificio Leitao da Cunha, CEP 04023-900, Vila Clementino, Sao Paulo (Brazil); Anadao, Carlos Augusto [Otorhinolaryngology Department, Sao Paulo Federal University-Paulista Medical School, Sao Paulo (Brazil); Prates, Jose Carlos [Morphology and Genetics Department, Sao Paulo Federal University-Paulista Medical School, Disciplina de Anatomia Descritiva e Topografica, Rua Botucatu, 740-Edificio Leitao da Cunha, CEP 04023-900, Vila Clementino, Sao Paulo (Brazil); Lederman, Henrique Manoel [Image Diagnosis Department, Sao Paulo Federal University-Paulista Medical School, Sao Paulo (Brazil)

    2007-01-15

    Objective: In the last two decades, advances in the computerized tomography (CT) field revise the internal and medium ear evaluation. Therefore, the aim of this study is to analyze the morphology and morphometric aspects of the vestibular aqueduct on the basis of computerized tomography images (CTI). Material and method: Computerized tomography images of vestibular aqueducts were acquired from patients (n = 110) with an age range of 1-92 years. Thereafter, from the vestibular aqueducts images a morphometric analysis was performed. Through a computerized image processing system, the vestibular aqueduct measurements comprised of its area, external opening, length and the distance from the vestibular aqueduct to the internal acoustic meatus. Results: The morphology of the vestibular aqueduct may be funnel-shaped, filiform or tubular and the respective proportions were found to be at 44%, 33% and 22% in children and 21.7%, 53.3% and 25% in adults. The morphometric data showed to be of 4.86 mm{sup 2} of area, 2.24 mm of the external opening, 4.73 mm of length and 11.88 mm of the distance from the vestibular aqueduct to the internal acoustic meatus, in children, and in adults it was of 4.93 mm{sup 2}, 2.09 mm, 4.44 mm, and 11.35 mm, respectively. Conclusions: Computerized tomography showed that the vestibular aqueduct presents high morphological variability. The morphometric analysis showed that the differences found between groups of children and adults or between groups of both genders were not statistically significant.

  20. Persistent asthma in adults: comparison of high resolution computed tomography of the lungs after one year of follow-up

    Directory of Open Access Journals (Sweden)

    Cukier Alberto

    2001-01-01

    Full Text Available OBJECTIVE: The aims of this study were to evaluate the role of high resolution computed tomography of the torax in detecting abnormalities in chronic asthmatic patients and to determine the behavior of these lesions after at least one year. METHOD: Fourteen persistent asthmatic patients with a mean forced expiratory volume in 1-second that was 63% of predicted and a mean forced expiratory volume in 1-second /forced vital capacity of 60% had two high resolution computed tomographys separated by an interval of at least one year. RESULTS: All 14 patients had abnormalities on both scans. The most common abnormality was bronchial wall thickening, which was present in all patients on both computed tomographys. Bronchiectasis was suggested on the first computed tomography in 5 of the 14 (36% patients, but on follow-up, the bronchial dilatation had disappeared in 2 and diminished in a third. Only one patient had any emphysematous changes; a minimal persistent area of paraseptal emphysema was present on both scans. In 3 patients, a "mosaic" appearance was observed on the first scan, and this persisted on the follow-up computed tomography. Two patients had persistent areas of mucoid impaction. In a third patient, mucus plugging was detected only on the second computed tomography. CONCLUSIONS: We conclude that there are many abnormalities on the high resolution computed tomography of patients with persistent asthma. Changes suggestive of bronchiectasis, namely bronchial dilatation, frequently resolve spontaneously. Therefore, the diagnosis of bronchiectasis by high resolution computed tomography in asthmatic patients must be made with caution, since bronchial dilatation can be reversible or can represent false dilatation. Nonsmoking chronic asthmatic subjects in this study had no evidence of centrilobular or panacinar emphysema.

  1. Persistent asthma in adults: comparison of high resolution computed tomography of the lungs after one year of follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Cukier, Alberto; Stelmach, Rafael; Kavakama, Jorge Issamu; Terra Filho, Mario; Vargas, Francisco [Sao Paulo Univ., SP (Brazil). Instituto do Coracao (InCor). Div. de Doencas Respiratorias

    2001-06-01

    The aims of this study were to evaluate the role of high resolution computed tomography of the thorax in detecting abnormalities in chronic asthmatic patients and to determine the behavior of these lesions after at least one year. Fourteen persistent asthmatic patients with a mean forced expiratory volume in 1-second that was 63% of predicted and a mean forced expiratory volume in 1-second /forced vital capacity of 60% had two high resolution computed tomography separated by an interval of at least one year. All 14 patients had abnormalities on both scans. The most common abnormality was bronchial wall thickening, which was present in all patients on both computed tomography. Bronchiectasis was suggested on the first computed tomography in 5 of the 14 (36%) patients, but on follow-up, the bronchial dilatation had disappeared in 2 and diminished in a third. Only one patient had any emphysematous changes; a minimal persistent area of para septal emphysema was present on both scans. In 3 patients, a 'mosaic' appearance was observed on the first scan, and this persisted on the follow-up computed tomography. Two patients had persistent areas of mucoid impaction. In a third patient, mucus plugging was detected only on the second computed tomography. We conclude that there are many abnormalities on the high resolution computed tomography of patients with persistent asthma. Changes suggestive of bronchiectasis, namely bronchial dilatation, frequently resolve spontaneously. Therefore, the diagnosis of bronchiectasis by high resolution computed tomography in asthmatic patients must be made with caution, since bronchial dilatation can be reversible or can represent false dilatation. Non smoking chronic asthmatic subjects in this study had no evidence of centrilobular or panacinar emphysema. (author)

  2. Optimization of linear-wavenumber spectrometer for high-resolution spectral domain optical coherence tomography

    Science.gov (United States)

    Wu, Tong; Sun, Shuaishuai; Wang, Xuhui; Zhang, Haiyan; He, Chongjun; Wang, Jiming; Gu, Xiaorong; Liu, Youwen

    2017-12-01

    Nonlinear detection of the spectral interferograms in wavenumber (k) space degrades the depth-dependent signal sensitivity in conventional linear-in- λ spectrometer based spectral domain optical coherence tomography (SDOCT). Linear- k spectrometer enables high sensitivity SDOCT imaging without the need of resampling the digitized non-linear-in- k data. Here we report an effective optimization method for linear- k spectrometer used in a high-resolution SDOCT system. The design parameters of the linear- k spectrometer, including the material of the dispersive prism, the prism vertex angle, and the rotation angle between the grating and prism, are optimized through the numerical simulation of the spectral interference signal. As guided by the optimization results, we constructed the linear- k spectrometer based SDOCT system and evaluated its imaging performances. The axial resolution of the system can be maintained to be higher than 9 . 1 μm throughout the imaging depth range of 2.42 mm. The sensitivity was experimentally measured to be 91 dB with - 6 dB roll-off within the depth range of 1.2 mm.

  3. Metastatic pulmonary calcification: high-resolution computed tomography findings in 23 cases

    Energy Technology Data Exchange (ETDEWEB)

    Belem, Luciana Camara; Souza, Carolina A.; Souza Junior, Arthur Soares; Escuissato, Dante Luiz; Hochhegger, Bruno; Nobre, Luiz Felipe; Rodrigues, Rosana Souza; Gomes, Antonio Carlos Portugal; Silva, Claudio S.; Guimaraes, Marcos Duarte; Zanetti, Glaucia; Marchiori, Edson, E-mail: edmarchiori@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Ottawa Hospital Research Institute, University of Ottawa, (Canada); Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil); Ultra X, Sao Jose do Rio Preto, SP (Brazil); Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil); Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), Porto Alegre, RS (Brazil); Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil). Hospital Universitario

    2017-07-15

    Objective: The aim of this study was to evaluate the high-resolution computed tomography (HRCT) findings in patients diagnosed with metastatic pulmonary calcification (MPC). Materials and Methods: We retrospectively reviewed the HRCT findings from 23 cases of MPC [14 men, 9 women; mean age, 54.3 (range, 26-89) years]. The patients were examined between 2000 and 2014 in nine tertiary hospitals in Brazil, Chile, and Canada. Diagnoses were established by histopathologic study in 18 patients and clinical-radiological correlation in 5 patients. Two chest radiologists analyzed the images and reached decisions by consensus. Results: The predominant HRCT findings were centrilobular ground-glass nodules (n = 14; 60.9%), consolidation with high attenuation (n = 10; 43.5%), small dense nodules (n = 9; 39.1%), peripheral reticular opacities associated with small calcified nodules (n = 5; 21.7%), and ground-glass opacities without centrilobular ground-glass nodular opacity (n = 5; 21.7%). Vascular calcification within the chest wall was found in four cases and pleural effusion was observed in five cases. The abnormalities were bilateral in 21 cases. Conclusion: MPC manifested with three main patterns on HRCT, most commonly centrilobular ground-glass nodules, often containing calcifications, followed by dense consolidation and small solid nodules, most of which were calcified. We also described another pattern of peripheral reticular opacities associated with small calcified nodules. These findings should suggest the diagnosis of MPC in the setting of hypercalcemia. (author)

  4. Implementation of a cryo-electron tomography tilt-scheme optimized for high resolution subtomogram averaging.

    Science.gov (United States)

    Hagen, Wim J H; Wan, William; Briggs, John A G

    2017-02-01

    Cryo-electron tomography (cryoET) allows 3D structural information to be obtained from cells and other biological samples in their close-to-native state. In combination with subtomogram averaging, detailed structures of repeating features can be resolved. CryoET data is collected as a series of images of the sample from different tilt angles; this is performed by physically rotating the sample in the microscope between each image. The angles at which the images are collected, and the order in which they are collected, together are called the tilt-scheme. Here we describe a "dose-symmetric tilt-scheme" that begins at low tilt and then alternates between increasingly positive and negative tilts. This tilt-scheme maximizes the amount of high-resolution information maintained in the tomogram for subsequent subtomogram averaging, and may also be advantageous for other applications. We describe implementation of the tilt-scheme in combination with further data-collection refinements including setting thresholds on acceptable drift and improving focus accuracy. Requirements for microscope set-up are introduced, and a macro is provided which automates the application of the tilt-scheme within SerialEM. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  5. Diagnosis of Ocular Surface Lesions Using Ultra-High Resolution Optical Coherence Tomography

    Science.gov (United States)

    Shousha, Mohamed Abou; Karp, Carol L.; Canto, Ana Paula; Hodson, Kelly; Oellers, Patrick; Kao, Andrew A.; Bielory, Brett; Matthews, Jared; Dubovy, Sander R.; Perez, Victor L.; Wang, Jianhua

    2012-01-01

    Purpose To assess the use of ultra high resolution optical coherence tomography (UHR-OCT) in the diagnosis of ocular surface lesions. Design Prospective, non-comparative, interventional case series. Participants Fifty four eyes of 53 consecutive patients with biopsy proven ocular surface lesions; 8 primary acquired melanosis, 5 amelanotic melanoma, 2 nevi, 19 ocular surface squamous neoplasia, 1 histiocytosis, 6 conjunctival lymphoma, 2 conjunctival amyloidosis, and 11 pterygia. Intervention UHR-OCT imaging of the ocular surface lesions. Main Outcome Measures Clinical course and photographs, UHR-OCT image and histopathological findings. Results UHR-OCT images of all examined ocular surface lesions showed close correlation with the obtained histopathological specimens. When clinical differential diagnosis of ocular surface lesions was broad, UHR-OCT images provided optical signs that guided towards a more specific diagnosis and management. In cases of amelanotic melanoma, conjunctival amyloidosis, and primary histiocytosis and in one case of ocular surface squamous neoplasia, UHR-OCT was instrumental in guiding the diagnosis. In those cases, UHR-OCT suggested that the presumed clinical diagnosis was incorrect and favored a diagnosis which was later confirmed by histopathological examination. Conclusions Correlations between UHR-OCT and histopathology confirm that UHR-OCT is an adjunctive diagnostic modality that can provide a non-invasive means to help and guide diagnosis and management of ocular surface lesions. PMID:23347984

  6. Preoperative Diagnosis of Extraglandular Invasion of Thyroid Papillary Carcinoma: High Resolution Sonography versus Multidetector Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yoon Jung; Hong, Hyun Pyo; Kwag, Hyon Joo; Kook, Shin Ho; Yun, Ji Sup; Kim, Dong Hoon [Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2009-03-15

    To compare the diagnostic efficacy of high-resolution sonography (HRS) and multidetector computed tomography (MDCT) in determining the presence of extraglandular invasion of thyroid papillary cancer and to define ultrasound (US) features of perithyroidal invasion that correlate with histopathological findings. We prospectively evaluated extracapsular invasion in 177 thyroid cancer patients using both HRS and MDCT. Receiver operating characteristics (ROC) were assessed with a four-point confidence scale (0 = no extracapsular invasion:1 = possible invasion:2 = probable invasion:3 = definite invasion) by two reviewers for each imaging modality. Sensitivity, specificity, and accuracy were analyzed for each modality, along with interobserver variability. MDCT had a mean area under the ROC curve larger than that of HRS (HRS = 0.733, MDCT = 0.807, p < 0.05). HRS and MDCT were significantly different with regard to diagnostic sensitivity, specificity, and accuracy for extrathyroidal extension (p < 0.05: HRS = 75.7%, 66.1%, and 69.8%, respectively: MDCT = 86.7%,69.7%, and 76%, respectively). Interobserver reliability was greater for MDCT than for HRS (kappa value, 0.861 versus 0.429). The cutoff value used in HRS for estimating the status of perithyroidal invasion was 2. Conclusion: HRS may be useful for preoperative investigation of thyroid papillary carcinoma extension, but it was inferior to MDCT because of lower diagnostic accuracy and lower interobserver reliability

  7. Region-of-interest cone beam computed tomography (ROI CBCT) with a high resolution CMOS detector

    Science.gov (United States)

    Jain, A.; Takemoto, H.; Silver, M. D.; Nagesh, S. V. S.; Ionita, C. N.; Bednarek, D. R.; Rudin, S.

    2015-03-01

    Cone beam computed tomography (CBCT) systems with rotational gantries that have standard flat panel detectors (FPD) are widely used for the 3D rendering of vascular structures using Feldkamp cone beam reconstruction algorithms. One of the inherent limitations of these systems is limited resolution (report on region-of-interest (ROI) CBCT with a high resolution CMOS detector (75 μm pixels, 600 μm HR-CsI) mounted with motorized detector changer on a commercial FPD-based C-arm angiography gantry (194 μm pixels, 600 μm HL-CsI). A cylindrical CT phantom and neuro stents were imaged with both detectors. For each detector a total of 209 images were acquired in a rotational protocol. The technique parameters chosen for the FPD by the imaging system were used for the CMOS detector. The anti-scatter grid was removed and the incident scatter was kept the same for both detectors with identical collimator settings. The FPD images were reconstructed for the 10 cm x10 cm FOV and the CMOS images were reconstructed for a 3.84 cm x 3.84 cm FOV. Although the reconstructed images from the CMOS detector demonstrated comparable contrast to the FPD images, the reconstructed 3D images of the neuro stent clearly showed that the CMOS detector improved delineation of smaller objects such as the stent struts (~70 μm) compared to the FPD. Further development and the potential for substantial clinical impact are suggested.

  8. Microarchitecture of the Vitreous Body: A High-Resolution Optical Coherence Tomography Study.

    Science.gov (United States)

    Uji, Akihito; Yoshimura, Nagahisa

    2016-08-01

    To report novel vitreous body microarchitecture findings using high-resolution spectral-domain optical coherence tomography (HR-SD-OCT). Prospective, cross-sectional study. Horizontal and vertical retinal cross-sectional images that were 10 mm long were acquired from 17 eyes of 17 young healthy volunteers using HR-SD-OCT with enhanced vitreous imaging (EVI). Images were acquired through the fovea, upper vessel arcade, and lower vessel arcade. Three new findings on vitreous body microarchitecture were found. First, material located between the retina and posterior vitreous cortex was easily detected in 90% of upper and lower vessel arcade scans. Most scans contained hyperreflective dots and multilayered hyperreflective lines around the detached vitreous cortex. Second, a lamellar structure was observed in the vitreous body in 70%-80% of all scans, excluding vertical scans of the upper arcade vessel area. Third, tubular zones of hypodensity were detected in >80% of scans, excluding horizontal scans of the macula. Interestingly, the location of tubular zones of hypodensity seemed to correspond with the location of retinal vessels. Subject age, refractive error, and axial length were not significantly different in scans with and without material between the retina and vitreous, lamellar structures, and tubular zones of hypodensity. The microarchitecture of the vitreous body can be visualized using HR-SD-OCT and EVI. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Quantifying Heterogeneity in Emphysema from High Resolution Computed Tomography: A Lung Tissue Research Consortium Study

    Science.gov (United States)

    Yilmaz, Cuneyt; Dane, Dan M.; Patel, Nova C.; Hsia, Connie C.W.

    2012-01-01

    Rationale and Objective To quantify spatial distribution of emphysema using high-resolution computed tomography (HRCT), we applied semi-automated analysis with internal attenuation calibration to measure regional air volume, tissue volume, and fractional tissue volume (FTV=tissue/[air+tissue] volume) in well-characterized patients studied by the Lung Tissue Research Consortium (LTRC). Methods HRCT was obtained at supine end-inspiration and end-expiration, and prone end-inspiration from 31 patients with mild, moderate, severe, or very severe emphysema (stages II–V, FEV1>75%, 51–75%, 21–50% and ≤20% predicted, respectively). Control data were from 20 healthy non-smokers (stage I). Each lobe was analyzed separately. Heterogeneity of FTV was assessed from coefficients of variation (CV) within and among lobes, and the kurtosis and skewness of FTV histograms. Results In emphysema, lobar air volume increased up to 177% except in the right middle lobe. Lobar tissue volume increased up to 107% in mild-moderate stages then normalized in advanced stages. Normally, FTV was up to 82% higher in lower than upper lobes. In mild-moderate emphysema, lobar FTV increased by up to 74% above normal at supine inspiration. In severe emphysema FTV declined below normal in all lobes and positions in correlation with pulmonary function (pemphysema distribution and heterogeneity from that in ILD. Early emphysema is associated with elevated tissue volume and FTV, consistent with hyperemia, inflammation or atelectasis. PMID:23122057

  10. Incomplete and accessory fissures of the lung evaluated by high-resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heřmanová, Zuzana, E-mail: zuzana.hermanova2@fnol.cz; Čtvrtlík, Filip, E-mail: filip.ctvrtlik@fnol.cz; Heřman, Miroslav, E-mail: herman@fnol.cz

    2014-03-15

    Purpose: The aim of our study was to assess incomplete and accessory interlobar fissures using volumetric thin-section high-resolution computed tomography (HRCT). Materials and methods: Retrospective assessment of HRCT examinations of 250 patients was performed. We assessed the localization, extension, and type of the incompleteness of fissures as well as the presence and localization of accessory fissures. We searched for possible correlation among the localization of interlobar fissures, the presence of incompleteness, and accessory fissures. Results: On the left side, an incomplete oblique fissure was found in 24%. The discontinuity was present in the parahilar region and the area of the incompleteness was most frequently between 21% and 40%. The right oblique fissure was incomplete in 35%, mostly parahilarly, with the most frequent discontinuity below 20%. An incomplete horizontal fissure was found in 74%. Accessory fissures were identified in 16% of patients, with the same frequency on both sides. The most frequent finding was accessory horizontal fissure with 8.0% on the left side, superior accessory fissure (7.2%) and inferior accessory fissure (5.2%) on the right side. No correlation was found among the localization of interlobar fissures, the presence of incompleteness, and accessory fissures. Conclusion: Incomplete and accessory fissures are frequent anatomic variations of interlobar fissures.

  11. Clinical utility of high-resolution pulmonary computed tomography in children with antibody deficiency disorders

    Energy Technology Data Exchange (ETDEWEB)

    Manson, D. [Department of Diagnostic Imaging, Hospital for Sick Children, 555 University Ave., Toronto, ON M5G 1X8 (Canada); Reid, B.; Dalal, I.; Roifman, C.M. [Department of Clinical Immunology, Hospital for Sick Children, Toronto, ON (Canada)

    1997-10-01

    Objective. To assess the value of high-resolution computed tomography (HRCT) in determining the extent and significance of lung disease in children with antibody deficiency states. Materials and methods. Seventy HRCT scans performed on 37 children with various antibody deficiency disorders over a 5-year period were retrospectively scored using a previously described demerit scoring system (0-25 with 0 = worst, 25 = best). Points are subtracted from 25 with increasing severity of disease. The potential correlations between CT scores and clinical factors, including age at diagnosis, age at CT, type of immunoglobulin deficiency, length of respiratory symptoms before diagnosis, number of pneumonias before diagnosis, type, length and success of therapy, patient compliance and pulmonary function tests (PFTs), were assessed. Results. Of the 37 children, a demonstrated 22 abnormal scans (CT score {<=} 22). All nine demonstrated bronchiectasis with a lower lobe and right middle lobe predominance. Statistically significant correlations were seen between severity of lung disease (CT score) and length of respiratory symptoms before diagnosis (p = 0.01), success of therapy (P = 0.001) and PFTs (P = 0.0008). Of seven children who were followed with repeated scans, 4 of the 7 demonstrated CT scores which improved on high-dose intravenous immunoglobulin replacement therapy. Conclusion. HRCT is a useful adjunct to demonstrate the extent and severity of lung disease at diagnosis and during therapy. Correlation with clinical factors suggests a higher risk group needing more aggressive management. (orig.). With 3 figs., 1 tab.

  12. Ultra high resolution optical coherence tomography in Boston type I keratoprosthesis.

    Science.gov (United States)

    Zarei-Ghanavati, Siamak; Betancurt, Carolina; Mas, Alma Michelle; Wang, Jianhua; Perez, Victor L

    2015-01-01

    To evaluate the anterior keratoprosthesis-cornea interface in eyes with Boston type I keratoprosthesis (Kpro). In a prospective non-interventional study, patients with Boston type I Kpro underwent ultra-high resolution optical coherence tomography (UHR-OCT) evaluation. The images were used to measure and describe characteristics of the anterior keratoprosthesis-cornea interface, epithelial interaction at the keratoprosthesis edge and the keratoprosthesis-cornea interface gap. Ten patients including 4 male and 6 female subjects with different preoperative diagnoses, i.e. 8 multiple corneal graft failures and 2 immunological ocular surface diseases, were studied. Mean age was 62.1 ± 20.0 (range, 33.0-83.0) years and mean interval between surgery and UHR-OCT evaluation was 15.2 ± 11.09 months. In eight patients, 360° epithelial growth over the peripheral edge of the Kpro was documented. We detected keratoprosthesis-cornea interface gap in three patients. One subject had developed postoperative endophthalmitis 8 months after surgery and the other two cases were among the high risk group according to the preoperative diagnosis. In one patient with severe ocular hypotony, the Kpro edge was inserted into the anterior stroma and covered with epithelium. UHR-OCT showed that corneal epithelium covers the Kpro edge and seals the potential space between the Kpro and cornea in 80% of cases. The presence of a gap in the interface and lack of epithelial sealing around the Kpro edge might be associated with endophthalmitis.

  13. High-resolution computed tomography findings in chronic eosinophilic vs. cryptogenic organising pneumonia.

    Science.gov (United States)

    Mehrian, P; Doroudinia, A; Rashti, A; Aloosh, O; Dorudinia, A

    2017-11-01

    The similar clinical and computed tomography (CT) characteristics of cryptogenic organising pneumonia (COP) and chronic eosinophilic pneumonia (CEP) make precise diagnosis challenging. To help differentiate between COP and CEP using high-resolution CT (HRCT). Clinical data and HRCT images of COP and CEP patients referred to Masih Daneshvari Hospital, Tehran, Iran, from 2007 to 2015 were reviewed. Diagnosis of COP or CEP was confirmed using open lung biopsy or a combination of transbronchial biopsy, bronchoalveolar lavage fluid (BALF) analysis, peripheral eosinophilia and a favourable response to corticosteroids. Ground-glass opacity, a dominant ground-glass pattern, upper-lobe pneumonia, increased thickness of bronchial walls and a mosaic pattern in the lungs were more frequent in CEP. Lower-lobe pneumonia, subpleural reticulation, a dominant consolidation pattern, nodules and masses, non-septal linear opacities, bronchial dilation and a reverse halo sign were more frequent in COP. History of asthma, wheezing and peripheral eosinophilia was significantly more common in CEP than in COP. Distinguishing between CEP and COP based on HRCT alone is not always possible. However, in many cases, especially if the correct diagnosis cannot be established by other means, certain HRCT features can be very helpful.

  14. Thoracic high-resolution computed tomography in the diagnosis of metastatic carcinoma.

    Science.gov (United States)

    Johnson, V S; Ramsey, I K; Thompson, H; Cave, T A; Barr, F J; Rudorf, H; Williams, A; Sullivan, M

    2004-03-01

    Three dogs were presented for investigation of recurrent pyrexia of unknown origin, chronic vomiting and respiratory distress, respectively. One dog was markedly underweight and the other two were cachexic. Physical examination and initial diagnostic tests failed to establish the underlying cause of the presenting signs. Thoracic radiographs were within normal limits for the age of the dog. In each case there was a high index of suspicion for an occult neoplastic process in view of the profound unexplained weight loss present. High-resolution computed tomography (HRCT) of the thorax was performed. The lung fields were divided into three zones for analysis and a novel classification scheme was used to describe the HRCT findings in each zone. Postmortem examination and histopathology confirmed the presence of an infiltrating metastatic carcinoma in all three cases. The HRCT changes correlated closely with the pathological findings. The authors conclude that HRCT of the lung should be considered for pulmonary metastatic screening in the dog and introduce a classification system for HRCT findings, based on terminology used in human medicine.

  15. Can chest high-resolution computed tomography findings diagnose pulmonary alveolar microlithiasis?

    Energy Technology Data Exchange (ETDEWEB)

    Francisco, Flavia Angelica Ferreira; Rodrigues, Rosana Souza; Barreto, Miriam Menna; Zanetti, Glaucia [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Escuissato, Dante Luiz [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil); Araujo Neto, Cesar Augusto [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Dept. de Medicina e Apoio Diagnostico; Silva, Claudio S. [Radiology Department, Facultad de Medicina Clinica Alemana, Universidad del Desarrollo, Santiago (Chile); Hochhegger, Bruno [Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), Porto Alegre, RS (Brazil); Marchiori, Edson, E-mail: edmarchiori@gmail.com [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil)

    2015-07-15

    Objective: the present study was aimed at retrospectively reviewing high-resolution computed tomography (HRCT) findings in patients with pulmonary alveolar microlithiasis in order to evaluate the frequency of tomographic findings and their distribution in the lung parenchyma. Materials and methods: thirteen patients (9 females and 4 males; age, 9 to 59 years; mean age, 34.5 years) were included in the present study. The HRCT images were independently evaluated by two observers whose decisions were made by consensus. The inclusion criterion was the presence of abnormalities typical of pulmonary alveolar microlithiasis at HRCT, which precludes lung biopsy. However, in 6 cases lung biopsy was performed. Results: ground-glass opacities and small parenchymal nodules were the predominant tomographic findings, present in 100% of cases, followed by small subpleural nodules (92.3%), subpleural cysts (84.6%), subpleural linear calcifications (69.2%), crazy-paving pattern (69.2%), fissure nodularity (53.8%), calcification along interlobular septa (46.2%) and dense consolidation (46.2%). Conclusion: as regards distribution of the lesions, there was preferential involvement of the lower third of the lungs. No predominance of distribution in axial and anteroposterior directions was observed. (author)

  16. High-Resolution Computed Tomography of Single Breast Cancer Microcalcifications in Vivo

    Directory of Open Access Journals (Sweden)

    Kazumasa Inoue

    2011-07-01

    Full Text Available Microcalcification is a hallmark of breast cancer and a key diagnostic feature for mammography. We recently described the first robust animal model of breast cancer microcalcification. In this study, we hypothesized that high-resolution computed tomography (CT could potentially detect the genesis of a single microcalcification in vivo and quantify its growth over time. Using a commercial CT scanner, we systematically optimized acquisition and reconstruction parameters. Two ray-tracing image reconstruction algorithms were tested: a voxel-driven “fast” cone beam algorithm (FCBA and a detector-driven “exact” cone beam algorithm (ECBA. By optimizing acquisition and reconstruction parameters, we were able to achieve a resolution of 104 μm full width at half-maximum (FWHM. At an optimal detector sampling frequency, the ECBA provided a 28 μm (21% FWHM improvement in resolution over the FCBA. In vitro, we were able to image a single 300 μm X 100 μm hydroxyapatite crystal. In a syngeneic rat model of breast cancer, we were able to detect the genesis of a single microcalcification in vivo and follow its growth longitudinally over weeks. Taken together, this study provides an in vivo “gold standard” for the development of calcification-specific contrast agents and a model system for studying the mechanism of breast cancer microcalcification.

  17. High-resolution computed tomography of single breast cancer microcalcifications in vivo.

    Science.gov (United States)

    Inoue, Kazumasa; Liu, Fangbing; Hoppin, Jack; Lunsford, Elaine P; Lackas, Christian; Hesterman, Jacob; Lenkinski, Robert E; Fujii, Hirofumi; Frangioni, John V

    2011-08-01

    Microcalcification is a hallmark of breast cancer and a key diagnostic feature for mammography. We recently described the first robust animal model of breast cancer microcalcification. In this study, we hypothesized that high-resolution computed tomography (CT) could potentially detect the genesis of a single microcalcification in vivo and quantify its growth over time. Using a commercial CT scanner, we systematically optimized acquisition and reconstruction parameters. Two ray-tracing image reconstruction algorithms were tested: a voxel-driven "fast" cone beam algorithm (FCBA) and a detector-driven "exact" cone beam algorithm (ECBA). By optimizing acquisition and reconstruction parameters, we were able to achieve a resolution of 104 μm full width at half-maximum (FWHM). At an optimal detector sampling frequency, the ECBA provided a 28 μm (21%) FWHM improvement in resolution over the FCBA. In vitro, we were able to image a single 300 μm × 100 μm hydroxyapatite crystal. In a syngeneic rat model of breast cancer, we were able to detect the genesis of a single microcalcification in vivo and follow its growth longitudinally over weeks. Taken together, this study provides an in vivo "gold standard" for the development of calcification-specific contrast agents and a model system for studying the mechanism of breast cancer microcalcification.

  18. Metastatic pulmonary calcification: high-resolution computed tomography findings in 23 cases

    Directory of Open Access Journals (Sweden)

    Luciana Camara Belém

    Full Text Available Abstract Objective: The aim of this study was to evaluate the high-resolution computed tomography (HRCT findings in patients diagnosed with metastatic pulmonary calcification (MPC. Materials and Methods: We retrospectively reviewed the HRCT findings from 23 cases of MPC [14 men, 9 women; mean age, 54.3 (range, 26-89 years]. The patients were examined between 2000 and 2014 in nine tertiary hospitals in Brazil, Chile, and Canada. Diagnoses were established by histopathologic study in 18 patients and clinical-radiological correlation in 5 patients. Two chest radiologists analyzed the images and reached decisions by consensus. Results: The predominant HRCT findings were centrilobular ground-glass nodules (n = 14; 60.9%, consolidation with high attenuation (n = 10; 43.5%, small dense nodules (n = 9; 39.1%, peripheral reticular opacities associated with small calcified nodules (n = 5; 21.7%, and ground-glass opacities without centrilobular ground-glass nodular opacity (n = 5; 21.7%. Vascular calcification within the chest wall was found in four cases and pleural effusion was observed in five cases. The abnormalities were bilateral in 21 cases. Conclusion: MPC manifested with three main patterns on HRCT, most commonly centrilobular ground-glass nodules, often containing calcifications, followed by dense consolidation and small solid nodules, most of which were calcified. We also described another pattern of peripheral reticular opacities associated with small calcified nodules. These findings should suggest the diagnosis of MPC in the setting of hypercalcemia.

  19. Fusing visual and clinical information for lung tissue classification in high-resolution computed tomography.

    Science.gov (United States)

    Depeursinge, Adrien; Racoceanu, Daniel; Iavindrasana, Jimison; Cohen, Gilles; Platon, Alexandra; Poletti, Pierre-Alexandre; Müller, Henning

    2010-09-01

    We investigate the influence of the clinical context of high-resolution computed tomography (HRCT) images of the chest on tissue classification. 2D regions of interest in HRCT axial slices from patients affected with an interstitial lung disease are automatically classified into five classes of lung tissue. Relevance of the clinical parameters is studied before fusing them with visual attributes. Two multimedia fusion techniques are compared: early versus late fusion. Early fusion concatenates features in one single vector, yielding a true multimedia feature space. Late fusion consisting of the combination of the probability outputs of two support vector machines. The late fusion scheme allowed a maximum of 84% correct predictions of testing instances among the five classes of lung tissue. This represents a significant improvement of 10% compared to a pure visual-based classification. Moreover, the late fusion scheme showed high robustness to the number of clinical parameters used, which suggests that it is appropriate for mining clinical attributes with missing values in clinical routine. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  20. [Diagnostic value of high-resolution computed tomography imaging in congenital inner ear malformations].

    Science.gov (United States)

    Sun, Xiaowei; Ding, Yuanping; Zhang, Jianji; Chen, Ying; Xu, Anting; Dou, Fenfen; Zhang, Zihe

    2007-02-01

    To observe the inner ear structure with volume rendering (VR) reconstruction and to evaluate the role of high-resolution computed tomography (HRCT) in congenital inner ear malformations. HRCT scanning was performed in 10 patients (20 ears) without ear disease (control group) and 7 patients (11 ears) with inner ear malformations (IEM group) and the original data was processed with VR reconstruction. The inner ear osseous labyrinth structure in the images generated by these techniques was observed respectively in the normal ears and malformation ears. The inner ear osseous labyrinth structure and the relationship was displayed clearly in VR imaging in the control group,meanwhile, characters and degree of malformed structure were also displayed clearly in the IEA group. Of seven patients (11 ears) with congenital inner ear malformations, the axial, MPR and VR images can display the site and degree in 9 ears. VR images were superior to the axial images in displaying the malformations in 2 ears with the small lateral semicircular canal malformations. The malformations included Mondini deformity (7 ears), vestibular and semicircular canal malformations (3 ears), vestibular aqueduct dilate (7 ears, of which 6 ears accompanied by other malformations) , the internal auditory canal malformation (2 ears, all accompanied by other malformations). HRCT can display the normal structure of bone inner ear through high quality VR reconstructions. VR images can also display the site and degree of the malformations three-dimensionally and intuitively. HRCT is valuable in diagnosing the inner ear malformation.

  1. High-resolution handheld rigid endomicroscope based on full-field optical coherence tomography

    Science.gov (United States)

    Benoit a la Guillaume, Emilie; Martins, Franck; Boccara, Claude; Harms, Fabrice

    2016-02-01

    Full-field optical coherence tomography (FF-OCT) is a powerful tool for nondestructive assessment of biological tissue, i.e., for the structural examination of tissue in depth at a cellular resolution. Mostly known as a microscopy device for ex vivo analysis, FF-OCT has also been adapted to endoscopy setups since it shows good potential for in situ cancer diagnosis and biopsy guidance. Nevertheless, all the attempts to perform endoscopic FF-OCT imaging did not go beyond lab setups. We describe here, to the best of our knowledge, the first handheld FF-OCT endoscope based on a tandem interferometry assembly using incoherent illumination. A common-path passive imaging interferometer at the tip of an optical probe makes it robust and insensitive to environmental perturbations, and a low finesse Fabry-Perot processing interferometer guarantees a compact system. A good resolution (2.7 μm transverse and 6 μm axial) is maintained through the long distance, small diameter relay optics of the probe, and a good signal-to-noise ratio is achieved in a limited 100 ms acquisition time. High-resolution images and a movie of a rat brain slice have been recorded by moving the contact endoscope over the surface of the sample, allowing for tissue microscopic exploration at 20 μm under the surface. These promising ex vivo results open new perspectives for in vivo imaging of biological tissue, in particular, in the field of cancer and surgical margin assessment.

  2. Three-dimensional grain fabric measurements using high-resolution X-ray computed tomography

    Science.gov (United States)

    Ketcham, Richard A.

    2005-07-01

    High-resolution X-ray computed tomography (HRXCT) provides detailed imagery of the interiors of rocks up to hand-sample size, non-destructively and in three dimensions. New tools described here allow these data to be used for analysis of grain fabrics. Two separate sets of measurement techniques have been developed. The first concentrates on quantifying individual crystals (phenocrysts, porphyroblasts) or other discrete objects or void spaces within a sample. Quantifiable properties include location, size, shape, orientation, and contact relationships with adjacent objects. The second set of techniques performs a more general fabric analysis on any distinguishable component in a sample. A fabric tensor can be computed based on a number of metrics, including the star volume distribution (SVD), star length distribution (SLD), and mean intercept length (MIL) methods. The fabric tensors provide principal component directions and magnitudes, which in turn provide a measure of degree of anisotropy and shape indices. Because the SVD and SLD measure only the material of interest, whereas the MIL is also influenced by spatial distribution, results can be divergent for sparse phases. Also introduced is a three-dimensional rose diagram that can be viewed interactively and inspected to reveal further details about non-orthogonal directional components. These techniques are demonstrated through analysis of a garnet-kyanite schist from Mica Dam, British Columbia.

  3. Total lung capacity by plethysmography and high-resolution computed tomography in COPD.

    Science.gov (United States)

    Garfield, Jamie L; Marchetti, Nathaniel; Gaughan, John P; Steiner, Robert M; Criner, Gerard J

    2012-01-01

    To characterize and compare total lung capacity (TLC) measured by plethysmography with high-resolution computed tomography (HRCT), and to identify variables that predict the difference between the two modalities. Fifty-nine consecutive patients referred for the evaluation of COPD were retrospectively reviewed. Patients underwent full pulmonary function testing and HRCT within 3 months. TLC was obtained by plethysmography as per American Thoracic Society/European Respiratory Society standards and by HRCT using custom software on 0.75 and 5 mm thick contiguous slices performed at full inspiration (TLC). TLC measured by plethysmography correlated with TLC measured by inspiratory HRCT (r = 0.92, P volume in 1 second/forced vital capacity [FVC] and FVC%), static lung volumes (residual volume, percent predicted [RV%], total lung capacity, percent predicted [TLC%], functional residual capacity, percent predicted [FRC%], and inspiratory capacity, percent predicted), and percent emphysema. TLC by plethysmography and HRCT both demonstrated significant inverse correlations with diffusion impairment. The absolute difference between TLC measured by plethysmography and HRCT increased as RV%, TLC%, and FRC% increased. Gas trapping (RV% and FRC%) independently predicted the difference in TLC between plethysmography and HRCT. In COPD, TLC by plethysmography can be up to 2 L greater than inspiratory HRCT. Gas trapping independently predicts patients for whom TLC by plethysmography differs significantly from HRCT.

  4. High-resolution computed tomography in silicosis: correlation with chest radiography and pulmonary function tests

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Agnaldo Jose [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Pedro Ernesto Univ. Hospital. Dept. of Respiratory Function]. E-mail: phel.lop@uol.com.br; Mogami, Roberto; Capone, Domenico; Jansen, Jose Manoel [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). School of Medical Sciences; Tessarollo, Bernardo [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Dept. of Radiology and Diagnostic Image; Melo, Pedro Lopes de [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. of Biology

    2008-05-15

    Objective: To correlate tomographic findings with pulmonary function findings, as well as to compare chest X-ray findings with high-resolution computed tomography (HRCT) findings, in patients with silicosis. Methods: A cross-sectional study was conducted in 44 non-smoking patients without a history of tuberculosis. Chest X-ray findings were classified according to the International Labour Organization recommendations. Using a semiquantitative system, the following HRCT findings were measured: the full extent of pulmonary involvement; parenchymal opacities; and emphysema. Spirometry and forced oscillation were performed. Pulmonary volumes were evaluated using the helium dilution method, and diffusing capacity of the lung for carbon monoxide was assessed. Results: Of the 44 patients studied, 41 were male. The mean age was 48.4 years. There were 4 patients who were classified as category 0 based on X-ray findings and as category 1 based on HRCT findings. Using HRCT scans, we identified progressive massive fibrosis in 33 patients, compared with only 23 patients when X-rays were used. Opacity score was found to correlate most closely with airflow, DLCO and compliance. Emphysema score correlated inversely with volume, DLCO and airflow. In this sample of patients presenting a predominance of large opacities (75% of the individuals), the deterioration of pulmonary function was associated with the extent of structural changes. Conclusions: In the early detection of silicosis and the identification of progressive massive fibrosis, HRCT scans are superior to X-rays. (author)

  5. Correlation between high-resolution computed tomography features and patients′ characteristics in chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Gupta Prem

    2008-01-01

    Full Text Available Background: During the last few decades, high-resolution computed tomography (HRCT has come up as a new diagnostic modality to diagnose emphysematous and chronic bronchitis components of chronic obstructive pulmonary disease (COPD. The present study was undertaken to evaluate for various quantitative and qualitative HRCT features in patients with COPD, and to detect patients′ characteristics that correlate with these HRCT features. Materials and Methods: Forty male patients with COPD attending the COPD clinic at a tertiary referral hospital and postgraduate medical institute were included in the study. Various HRCT features, including tracheal index, thoracic cage ratio, sterno-aortic distance, thoracic cross-sectional area, vascular attenuation, vascular distortion, mosaic attenuation pattern, and directly visible small airways, were evaluated and correlated with patients′ characteristics, including age, duration of illness, quantum of smoking, dyspnea score, quality-of-life index, and various spirometric indices. Results: We found significant correlations of various quantitative and qualitative HRCT features with age, duration of illness, quantum of smoking, quality-of-life index, and the spirometric indices showing the extent of airways obstruction. Conclusions: Various quantitative and qualitative HRCT features were found to correlate with patients′ characteristics, spirometric indices, and health-related quality-of-life score, suggesting that HRCT is useful not only in detecting emphysema and its various subtypes but also in predicting the extent and severity of COPD

  6. Role of High Resolution Computed Tomography of Mastoids in Planning Surgery for Chronic Suppurative Otitis Media.

    Science.gov (United States)

    Chatterjee, Pritam; Khanna, Swagata; Talukdar, Ramen

    2015-09-01

    Chronic suppurative otitis media (CSOM) presents with a typical history of recurrent otorrhoea with tympanic membrane perforation. The diagnosis of cholesteatoma is usually made on otologic examination. High resolution computed tomography (HRCT) is indicated to evaluate the extension and the complications of cholesteatoma. The aim of the work was to study the role of HRCT in detecting, evaluating diagnosing and managing CSOM. All patients presenting with CSOM who were planned for mastoid exploration surgery in department of ENT, Gauhati Medical College and Hospital within a period of 2 years-from 1st January, 2013 to 31th December, 2014, were taken up for the study. HRCT mastoids done routinely before cholesteatoma surgery, but with improved resolution, to characterize all middle ear structures and complications of the disease prior to surgery, might guide as road map during mastoid explorations for unsafe CSOM. The important role of HRCT lies on the early detection of cholesteatoma, and more conservative surgical procedures can be used to eradicate the disease.

  7. Functional control of the renal transplant via sequential computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Treugut, H.; Nyman, U.; Hildell, J.; Molde, A.

    1981-08-01

    The enhancement of cortex medulla and arteria iliaca can be visualized separately, evaluated densitometrically and represented graphically by means of sequential computerized tomography of the renal transplant following intravenous contrast medium bolus injection. Since this enhancement performance is mainly dependent on perfusion, it is possible to determine the perfusion value of individual measurement areas. For example, a cortical defective perfusion, as is known in rejection, becomes evident as a flattening-out of the initial rise of cortex enhancement and can be distinguished from the largely normal type of curve obtained in acute tubular necrosis (ATN). The angiographically known prolonged 'wash-out time' in rejection corresponds to a long-lasting corticomedullary density gradient. Despite restricted informative value because of the relatively small number of patients, it appears that sequential computerized tomography enables differentiation of postoperative anuria.

  8. Computerized tomography in the diagnosis and treatment of orbital cellulitis

    Energy Technology Data Exchange (ETDEWEB)

    Hirsch, M.; Lifshitz, T.

    1988-05-01

    Acute sinusitis remains the major cause of orbital cellulitis in children, despite the extensive use of antibiotics. Staging of orbital cellulitis on the basis of clinical signs is difficult but is easily achieved by computerized tomography. The CT findings in a series of 9 children with orbital cellulitis in different stages are reported. The information obtained by CT contributes to the selection of an adequate surgical approach, if a therapeutic trial with antibiotics fails.

  9. Pulmonary function and high-resolution computed tomography examinations among offshore drill floor workers.

    Science.gov (United States)

    Kirkhus, Niels E; Skare, Øivind; Ulvestad, Bente; Aaløkken, Trond Mogens; Günther, Anne; Olsen, Raymond; Thomassen, Yngvar; Lund, May Brit; Ellingsen, Dag G

    2017-12-01

    The aim of this study was to assess short-term changes in pulmonary function in drill floor workers currently exposed to airborne contaminants generated as a result of drilling offshore. We also aimed to study the prevalence of pulmonary fibrosis using high-resolution computed tomography (HRCT) scans of another group of previously exposed drill floor workers. Pulmonary function was measured before and after a 14-day work period in a follow-up study of 65 drill floor workers and 65 referents. Additionally, 57 other drill floor workers exposed to drilling fluids during the 1980s were examined with HRCT of the lungs in a cross-sectional study. The drill floor workers had a statistically significant decline in forced expiratory volume in 1 s (FEV 1 ) across the 14-day work period after adjustment for diurnal variations in pulmonary function (mean 90 mL, range 30-140 mL), while the small decline among the referents (mean 20 mL, range - 30 to 70 mL) was not of statistical significance. Larger declines in FEV 1 among drill workers were associated with the fewer number of days of active drilling. There were no signs of pulmonary fibrosis related to oil mist exposure among the other previously exposed drill floor workers. After 14 days offshore, a statistically significant decline in FEV 1 was observed in the drill floor workers, which may not be related to oil mist exposure. No pulmonary fibrosis related to oil mist exposure was observed.

  10. Quantifying heterogeneity in emphysema from high-resolution computed tomography: a lung tissue research consortium study.

    Science.gov (United States)

    Yilmaz, Cuneyt; Dane, Dan M; Patel, Nova C; Hsia, Connie C W

    2013-02-01

    To quantify spatial distribution of emphysema using high-resolution computed tomography (HRCT), we applied semiautomated analysis with internal attenuation calibration to measure regional air volume, tissue volume, and fractional tissue volume (FTV = tissue/[air + tissue] volume) in well-characterized patients studied by the Lung Tissue Research Consortium (LTRC). HRCT was obtained at supine end-inspiration and end-expiration, and prone end-inspiration from 31 patients with mild, moderate, severe, or very severe emphysema (stages II-V, forced expiratory volume at 1 second >75%, 51%-75%, 21%-50% and ≤20% predicted, respectively). Control data were from 20 healthy non-smokers (stage I). Each lobe was analyzed separately. Heterogeneity of FTV was assessed from coefficients of variation (CV) within and among lobes, and the kurtosis and skewness of FTV histograms. In emphysema, lobar air volume increased up to 177% above normal except in the right middle lobe. Lobar tissue volume increased up to 107% in mild-moderate stages then normalized in advanced stages. Normally, FTV was up to 82% higher in lower than upper lobes. In mild-moderate emphysema, lobar FTV increased by up to 74% above normal at supine inspiration. In severe emphysema, FTV declined below normal in all lobes and positions in correlation with pulmonary function (P < .05). Markers of FTV heterogeneity increased steadily with disease stage in correlation with pulmonary function (P < .05); the pattern is distinct from that seen in interstitial lung disease (ILD). CT-derived biomarkers differentiate the spatial patterns of emphysema distribution and heterogeneity from that in ILD. Early emphysema is associated with elevated tissue volume and FTV, consistent with hyperemia, inflammation or atelectasis. Published by Elsevier Inc.

  11. Pulmonary function parameters in high-resolution computed tomography phenotypes of chronic obstructive pulmonary disease.

    Science.gov (United States)

    Sun, Xian Wen; Gu, Shu Yi; Li, Qing Yun; Ren, Lei; Shen, Ji Min; Wan, Huan Ying; Huang, Shao Guang; Deng, Wei Wu

    2015-03-01

    Heterogeneity of clinical presentation of chronic obstructive pulmonary disease (COPD) attributes to different pathological basis. High-resolution computed tomography (HRCT) phenotypes of COPD may reflex the pathological basis of COPD indirectly by evaluating the small airway inflammation and emphysema. How the pulmonary function related with different HRCT phenotypes has not been well known. The aim was to explore the features of pulmonary function parameters in the 3 phenotypes. Sixty-three stable COPD patients were allocated in 3 groups based on HRCT findings: phenotype A (absence of emphysema, with minimal evidence of emphysema with or without bronchial wall thickening [BWT]), phenotype E (emphysema without BWT) and phenotype M (emphysema with BWT). The pulmonary function testing was also analyzed. The values of forced expiratory volume in 1 second (FEV1)/forced vital capacity (FVC%), FEV1% and maximum expiratory flows (MEF)50% were the highest in phenotype A (P 4.0 were more prevalence in phenotype A than in E and M (odds ratio = 2.214; P 40% were higher in phenotype E than in A and M (odds ratio = 3.906; P < 0.05). Receiver operating characteristic analysis showed that the cutoff value of MEF50/MEF25 ratio for identifying phenotype A was 2.5, with sensitivity 66.7% and specificity 92.9%. The cutoff value of RV/TLC% for identifying phenotype E was 57.4%, with sensitivity 75.0% and specificity 79.1%. The different features of pulmonary function parameters were found in various HRCT phenotypes; MEF50/MEF25 ratio could imply phenotype A, whereas RV/TLC% may be the indicator of phenotype E.

  12. High Resolution Peripheral Quantitative Computed Tomography for Assessment of Bone Quality

    Science.gov (United States)

    Kazakia, Galateia

    2014-03-01

    The study of bone quality is motivated by the high morbidity, mortality, and societal cost of skeletal fractures. Over 10 million people are diagnosed with osteoporosis in the US alone, suffering 1.5 million osteoporotic fractures and costing the health care system over 17 billion annually. Accurate assessment of fracture risk is necessary to ensure that pharmacological and other interventions are appropriately administered. Currently, areal bone mineral density (aBMD) based on 2D dual-energy X-ray absorptiometry (DXA) is used to determine osteoporotic status and predict fracture risk. Though aBMD is a significant predictor of fracture risk, it does not completely explain bone strength or fracture incidence. The major limitation of aBMD is the lack of 3D information, which is necessary to distinguish between cortical and trabecular bone and to quantify bone geometry and microarchitecture. High resolution peripheral quantitative computed tomography (HR-pQCT) enables in vivo assessment of volumetric BMD within specific bone compartments as well as quantification of geometric and microarchitectural measures of bone quality. HR-pQCT studies have documented that trabecular bone microstructure alterations are associated with fracture risk independent of aBMD.... Cortical bone microstructure - specifically porosity - is a major determinant of strength, stiffness, and fracture toughness of cortical tissue and may further explain the aBMD-independent effect of age on bone fragility and fracture risk. The application of finite element analysis (FEA) to HR-pQCT data permits estimation of patient-specific bone strength, shown to be associated with fracture incidence independent of aBMD. This talk will describe the HR-pQCT scanner, established metrics of bone quality derived from HR-pQCT data, and novel analyses of bone quality currently in development. Cross-sectional and longitudinal HR-pQCT studies investigating the impact of aging, disease, injury, gender, race, and

  13. Ultra high resolution optical coherence tomography in Boston type I keratoprosthesis

    Directory of Open Access Journals (Sweden)

    Siamak Zarei-Ghanavati

    2015-01-01

    Full Text Available Purpose: To evaluate the anterior keratoprosthesis-cornea interface in eyes with Boston type I keratoprosthesis (Kpro. Methods: In a prospective non-interventional study, patients with Boston type I Kpro underwent ultra-high resolution optical coherence tomography (UHR-OCT evaluation. The images were used to measure and describe characteristics of the anterior keratoprosthesis-cornea interface, epithelial interaction at the keratoprosthesis edge and the keratoprosthesis-cornea interface gap. Results: Ten patients including 4 male and 6 female subjects with different preoperative diagnoses, i.e. 8 multiple corneal graft failures and 2 immunological ocular surface diseases, were studied. Mean age was 62.1 ± 20.0 (range, 33.0-83.0 years and mean interval between surgery and UHR-OCT evaluation was 15.2 ± 11.09 months. In eight patients, 360° epithelial growth over the peripheral edge of the Kpro was documented. We detected keratoprosthesis-cornea interface gap in three patients. One subject had developed postoperative endophthalmitis 8 months after surgery and the other two cases were among the high risk group according to the preoperative diagnosis. In one patient with severe ocular hypotony, the Kpro edge was inserted into the anterior stroma and covered with epithelium. Conclusion: UHR-OCT showed that corneal epithelium covers the Kpro edge and seals the potential space between the Kpro and cornea in 80% of cases. The presence of a gap in the interface and lack of epithelial sealing around the Kpro edge might be associated with endophthalmitis.

  14. High-resolution computed tomography findings in elderly patients with asthma

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, Sevda [Department of Radiology, School of Medicine, University of Kirikkale, 71100 Kirikkale (Turkey)]. E-mail: dryilmazsevda@yahoo.com; Ekici, Aydanur [Department of Pulmonary Medicine, School of Medicine, University of Kirikkale, 71100 Kirikkale (Turkey); Ekici, Mehmet [Department of Pulmonary Medicine, School of Medicine, University of Kirikkale, 71100 Kirikkale (Turkey); Keles, Hatice [Department of Internal Medicine, School of Medicine, University of Kirikkale, 71100 Kirikkale (Turkey)

    2006-08-15

    Objective: Based on the hypothesis that airway remodelling is related to the duration of asthma, HRCT scanning should show greater abnormalities in the early-onset than the late-onset asthmatics. It was, therefore, intended to assess the presence and the frequency of airway and parenchymal abnormalities with high-resolution computed tomography (HRCT) in elderly asthmatic patients, and to determine whether these abnormalities are related to the duration of asthma. Patients and methods: Sixty-eight clinically stable asthmatic patients aged {>=}60 yr were included in this prospective study. The patients were separated into two groups according to the duration of symptoms as late-onset asthma (n = 31) with disease duration of <5 yr, and early-onset asthma (n = 37) with disease duration of {>=}5 yr. All patients were lifelong non-smoker and had been using inhaled beta agonists and inhaled steroids. HRCT-scanning and histamine inhalation test were performed on all patients. Results: In comparison with late-onset asthmatic patients, those with early-onset asthma had significantly higher frequency of emphysema (21.6% versus 0.0%, p = 0.006), bronchial dilatation (13.9% versus 0.0%, p 0.03) and bronchial wall thickness (41.7% versus 12.9%, p = 0.01). Multiple logistic regression analysis identified that early-onset of disease was an independent risk factor for the presence of irreversible HRCT-scan abnormalities in elderly asthmatics [odds ratio (OR): 9.4 (2.7-32.7), p 0.00001]. Conclusion: Present data suggest that HRCT abnormalities in early-onset elderly asthmatics reflect parenchymal and airway changes that become irreversible throughout the long course of the disease.

  15. The subclinical involvement of the lung in rheumatoid arthritis: evaluation by high-resolution computed tomography

    Directory of Open Access Journals (Sweden)

    E. Bichi Secchi

    2011-09-01

    Full Text Available Pulmonary involvement is one of the most frequent extra-articular manifestations of rheumatoid arthritis (RA and represents a serious complication, being the second cause of death after infection. High-resolution computed tomography (HRCT, owing to its increased sensitivity and diagnostic accuracy respect to the conventional chest radiograph (CXR, allows to detect pulmonary abnormalities in RA patients more frequently than CXR. The aim of this study was to assess pulmonary involvement by HRCT in lifelong non-smoking RA patients without symptoms and clinical signs of pulmonary disease. Seventy-two patients (54 women and 18 men with a mean age of 56.8±10.4 years (range, 40- 77 years and mean duration of disease of 6.9±4.7 years (range, 2-12 years entered the study. 52/72 (72% were positive for rheumatoid factor (> 20 UI/ml. Standard CXR and HRCT were carried out in each patient. CXR showed a mild interstitial fibrosis in 7 patients (9.7%, whereas HRCT demonstrated pulmonary abnormalities in an higher number of them (22/72 = 30.5%. The most frequent abnormal findings on HRCT were irregular pleural margins (13.8% and septal/subpleural lines (18%, both compatible with pulmonary fibrosis. Ground-glass opacities were found in 8.3% of the patients. Pulmonary nodules (diameter, range 0,5-2 cm predominantly located in the subpleural portions of the lung, were demonstrated in the same percentage (8.3% of patients. Small airway involvement, represented by bronchiectasis/bronchioloectasis, was shown in 15.2% of patients. Subpleural cysts were present in two cases (2.8%. No patient had evidence of honeycombing on HRCT. In conclusion, HRCT is an accurate, non-invasive and safe method of diagnosing lung abnormalities in RA patients without signs and clinical symptoms of pulmonary disease...

  16. Variations in the labyrinthine segment of facial nerve canal revealed by high-resolution computed tomography.

    Science.gov (United States)

    Jin, Aiyan; Xu, Peng; Qu, Fengqin

    2017-08-09

    To study variations in the labyrinthine segment of fallopian canal and the associated middle and inner ear malformations. The high-resolution computed tomography (HRCT) images of the temporal bone in 24 patients with congenital variations in the labyrinthine segment of fallopian canal were analyzed retrospectively. The length of labyrinthine segment of the facial nerve and angle of the first genu of 10 normal subjects were also measured. Based on the original axial images, multi-planar reformation (MPR) and curved-planar reformation (CPR) images of bilateral ossicular chains, inner ear structure and fallopian canal were reconstructed. HRCT features of congenital variations in the labyrinthine segment of the facial nerve were analyzed, including its beginning site, dehiscence, length, angle of the first genu and the associated middle and inner ear malformations. Among the normal subjects, the length of labyrinthine segment of the facial nerve was 3.56±0.41mm, and angle of the first genu was 71.87±8.09°. Five types of variations in the labyrinthine segment of the facial nerve were found in 45 ears of 24 cases, including dehiscence in geniculate fossa in 25 ears, anteromedial displacement at the beginning site in 27 ears (widening of Bill's bar in 7 cases), enlargement of the angle of the first genu in 30 ears with an average value of 107.2° (96.0-126.0°), increase of length in 30 ears with an average length of 6.8mm (5.2-8.3mm) and bifurcation in one ear. Associated middle ear malformation in 6 ears and inner ear malformation in 36 ears were also found. A variety of congenital variations may occur in the labyrinthine segment of the facial nerve and they are often associated with middle or inner ear malformations, which can be clearly displayed by HRCT with MPR or CPR images. Copyright © 2017. Published by Elsevier B.V.

  17. High resolution computed tomography and classification of children with interstitial lung diseases.

    Science.gov (United States)

    He, M L; Lai, H; Cao, Y; Shuai, Y Z; Yu, S C

    2014-06-09

    High resolution computed tomography (HRCT) was used to classify children with interstitial lung diseases (ILD). Sixty children with ILD underwent HRCT in supine position under free-respiratory conditions during scanning. Children under 5 years old were sedated with chloral hydrate and the scanning scope was from the lung apex to the diaphragm. In children older than 5 years old, scans were obtained at three levels: aortic arch, tracheal carina, and 1 cm above the right diaphragm. Five infectious patients were followed up. Two experienced radiologists read the films blindly to observe the type and distribution of ground-glass opacities and bronchovascular bundle abnormalities. Bronchovascular bundles were thick in 49 patients, and were thick and stiff in 27 patients. Of the 41 infectious patients, 39 showed thickened bronchovascular bundles, and 26 showed thick and stiff bronchovascular bundles. Of the 19 non-infectious patients, bronchovascular bundles were thickened in 10 patients, and were thick and stiff in 1 patient. Forty-one patients showed lobular ground-glass opacity (32 infectious, 9 non-infectious). Twenty-seven patients showed both bronchovascular bundle abnormality and lobular ground-glass opacity (20 infectious, 7 non-infectious). Eighteen patients showed patchy or mosaic ground-glass opacity (16 infectious, 2 non-infectious). There were 4 cases of bronchiectasis. HRCT is the first non-invasive diagnostic method for children with ILD, and its different manifestations can be classified. In early manifestation, bronchovascular bundles were abnormal and complicated with lobular ground-glass opacity. Patchy ground-glass opacity was the most common manifestation, and appeared to be difficult to disappear. Bronchiectasis indicated that the disease is irretrievable.

  18. Radiologist agreement on the quantification of bronchiectasis by high-resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Milene Carneiro Barbosa de, E-mail: milenebrito7@gmail.com [Clinica da Imagem do Tocantins, Araguaia, TO (Brazil); Ota, Mauricio Kenji [Fundacao Instituto de Pesquisa e Estudos de Diagnostico por Imagem (FIDI), Sao Paulo, SP (Brazil); Leitao Filho, Fernando Sergio Studart [Universidade de Fortaleza (UNIFOR), Fortaleza, CE (Brazil); Meirelles, Gustavo de Souza Portes [Grupo Fleury, Sao Paulo, SP (Brazil)

    2017-01-15

    Objective: To evaluate radiologist agreement on the quantification of bronchiectasis by high-resolution computed tomography (HRCT). Materials and Methods: The HRCT scans of 43 patients with bronchiectasis were analyzed by two radiologists, who used a scoring system to grade the findings. Kappa (κ) values and overall agreement were calculated. Results: For the measurement and appearance of bronchiectasis, the interobserver agreement was moderate (κ = 0.45 and κ = 0.43, respectively), as was the intraobserver agreement (κ = 0.54 and κ = 0.47, respectively). Agreement on the presence of mucous plugging was fair, for central distribution (overall interobserver agreement of 68.3% and κ = 0.39 for intraobserver agreement) and for peripheral distribution (κ = 0.34 and κ = 0.35 for interobserver and intraobserver agreement, respectively). The agreement was also fair for peri bronchial thickening (κ = 0.21 and κ = 0.30 for interobserver and intraobserver agreement, respectively). There was fair interobserver and intraobserver agreement on the detection of opacities (κ = 0.39 and 71.9%, respectively), ground-glass attenuation (64.3% and κ = 0.24, respectively), and cysts/bullae (κ = 0.47 and κ = 0.44, respectively). Qualitative analysis of the HRCT findings of bronchiectasis and the resulting individual patient scores showed that there was an excellent correlation between the observers (intra class correlation coefficient of 0.85 and 0.81 for interobserver and intraobserver agreement, respectively). Conclusion: In the interpretation of HRCT findings of bronchiectasis, radiologist agreement appears to be fair. In our final analysis of the findings using the proposed score, we observed excellent interobserver and intraobserver agreement. (author)

  19. Surface anatomy of the pulmonary fissures determined by high-resolution computed tomography.

    Science.gov (United States)

    Heřmanová, Zuzana; Ctvrtlík, Filip; Heřman, Miroslav

    2012-10-01

    The aim of our study was to describe the surface anatomy of the interlobar fissures using volumetric thin-section high-resolution computed tomography (HRCT). Retrospective assessment of HRCT examinations of 250 patients was performed. The localization of the oblique fissures was marked at three sites: posteriorly at its most superior medial limit, laterally in the midaxillary line, and inferiorly at the junction of the middle and lateral thirds of the hemithorax; posteriorly and laterally, this was to the nearest rib whilst inferiorly the position was described in relation to the diaphragm or chest wall. The localization of the horizontal fissure was marked anteriorly in relation to the nearest rib (or costal cartilage) and posteriorly where it intersected with the oblique fissure (superior, middle, or inferior third). Shapes of the fissures and differences between inspiration and expiration were also documented. Descriptive statistics were used to report the most frequent positions. The most frequent localization of the oblique fissure on the left side was posteriorly at the fourth rib (45%), laterally at the sixth rib (52%), and inferiorly in the anterior third of the hemidiaphragm (60%). The right oblique fissure was located posteriorly at the fifth rib (50%), laterally at the sixth rib (50%), and inferiorly in the anterior third of the hemidiaphragm (71%). The horizontal fissure most commonly originated in the middle third of the oblique fissure (61%) and met the anterior thoracic wall at the level of the fourth rib (51%). The most frequent shape of the left oblique fissure was linear (78%), whereas S-shaped and linear configurations (28% each) were most frequent on the right. No difference was found in the surface markings of the fissures between inspiration and expiration in 90% of cases. The considerable individual variation in the position and shape of the interlobar fissures helps to explain the variable descriptions of their surface anatomy in the

  20. High resolution electrical resistivity tomography of golf course greens irrigated with reclaimed wastewater: Hydrological approach

    Science.gov (United States)

    Tapias, Josefina C.; Lovera, Raúl; Himi, Mahjoub; Gallardo, Helena; Sendrós, Alexandre; Marguí, Eva; Queralt, Ignasi; Casas, Albert

    2014-05-01

    tomography is a non-invasive and cost-effective technique for high resolution characterizing the subsurface below golf course greens. The obtained models have provided detailed information on the lateral and vertical variability of each the subsurface and from an empirical correlation between the values of electrical resistivity and hydraulic permeability to assess the preferred areas of drainage that could pose in risk to the vulnerability of the underlying aquifers.

  1. Relationship between high-resolution computed tomography densitometry and audiometry in otosclerosis.

    Science.gov (United States)

    Zhu, Mei-mei; Sha, Yan; Zhuang, Pei-yun; Olszewski, Aleksandra E; Jiang, Jia-qi; Xu, Jiang-hong; Xu, Chen-mei; Chen, Bing

    2010-12-01

    The aim of this study is to evaluate the usefulness of high-resolution computed tomography (HRCT) densitometry in the diagnosis of otosclerosis and to investigate the relationship between CT densitometry and audiometry. HRCT findings and audiometry were compared among 34 patients (34 ears, the otosclerosis group) with surgically confirmed otosclerosis between January 2007 and December 2007 and 33 patients (33 opposite normal ears, the control group) with facial paralysis diagnosed at the same period of time. Seven regions of interest (ROI) were set manually around the otic capsule on the axial slice of 0.75-mm-thick CT image. The mean CT values of these seven regions were measured. In each ROI, the mean CT value of the otosclerosis group and that of the control group were compared. Based on the CT findings, the ears with otosclerosis were classified into two groups: Group A showed no pathological CT findings; Group B showed low density around the cochlea. In the otosclerosis group, the relationship between the findings of CT and the results of audiometry was analyzed. The mean CT values in the area posterior to the oval window and anterior to the oval window were significantly lower for the otosclerosis group compared with the control group (the former t=-2.030, p=0.046; the latter Z=-4.979, p<0.01). Group A consisted of 30 patients, 7 of which (23.33%) exhibited conductive hearing loss, and 23 of which (76.67%) exhibited mixed hearing loss; Group B had 4 patients, all with mixed hearing loss. For the otosclerosis group, the mean CT value in the area posterior to the oval window was positively correlated with the mean air conduction threshold (r=0.4273, p=0.0117) and with the mean air-bone gap (r=0.3995, p=0.0192). Quantitative evaluation of CT with slices less than 1mm in thickness may provide important information for the diagnosis and assessment of otosclerosis which are unattainable through other methods. Copyright (c) 2010 Elsevier Ireland Ltd. All rights

  2. Bronchial reactivity in hyperresponsive patients and healthy individuals: demonstration with high resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Schueller, G. E-mail: gerd.schueller@univie.ac.at; Neumann, K.; Helbich, T.; Riemer, H.; Backfrieder, W.; Sertl, K.; Herold, C.J

    2004-11-01

    Objective: High resolution computed tomography (HRCT) was used to assess the extent of bronchial reactivity after inhalative bronchoprovocation and dilation in hyperresponsive patients and healthy subjects. Patients and methods: Patients with mild intermittent asthma, 15 with a >20% decrease in FEV{sub 1} and a >10 mmHg (PC{sub 20}+) in PaO{sub 2}, 12 with a <20% decrease in FEV{sub 1} and a >10 mmHg (PC{sub 20}-) in PaO{sub 2} after provocation, and eight healthy humans were included in the study. Changes in cross-sectional area in a total of 1256 bronchi and in bronchial wall area (792 bronchi) were evaluated after histamine-triggered bronchoprovocation and salbutamol-induced bronchodilation at high lung volumes (FVC 80%). Data were compared with the results of pulmonary function tests (FEV{sub 1}, PaO{sub 2}, PaCO{sub 2}). Results: In all groups, a significant decrease in bronchial cross-sectional area (P<0.001) and a significant increase in bronchial wall area (P<0.001) were observed subsequent to bronchoprovocation. After bronchodilation, the increase in cross-sectional area (P<0.001) and the further increase in airway wall area (P<0.01) were significant in all groups. In PC{sub 20}+ and PC{sub 20}- asthmatics, significant differences (P<0.05) in PaO{sub 2}, >10 mmHg between baseline and provocation were observed. In healthy persons, the PaO{sub 2} decrease was <10 mmHg (P>0.05). After histamine provocation, the decrease in FEV{sub 1} was measured in the PC{sub 20}+ group, whereas a <20% FEV{sub 1} decrease was found in the PC{sub 20}- and the control groups, respectively. No significant correlations were observed between radiological data and the results of pulmonary function tests. Conclusions: HRCT demonstrated bronchial reactivity in hyperresponsive patients and, unexpectedly, in healthy subjects. The applied pulmonary function tests failed to characterize bronchial reactions in the healthy subjects. Based on these results, HRCT is a useful tool by which

  3. A new method for tibial torsion measurement by computerized tomography.

    Science.gov (United States)

    Madadi, Firooz; Madadi, Firoozeh; Maleki, Arash; Shamie, Arya Nick; Washington, Eleby Rudolph; Yazdanshenas, Hamed

    2016-03-01

    Computerized tomography (CT) is the gold standard technique for tibial torsion assessment. This study compared two methods of tibial torsion assessment and proposed a new method, which could be of value in cases of abnormal fibular changes. The CT-scanograms of 60 participants were assessed by using two different techniques, differed in determination of the distal tibial axis. The interobserver reliability was 0.861 and 0.863 in the first and second methods, respectively. The intraobserver reliability in both measurement methods was 0.868. We proposed a reliable method, independent of the fibular midpoint, in assessment of tibial torsion by CT.

  4. Computerized tomography used as a routine procedure at postmortem investigations

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2009-01-01

    This is a prospective investigation of a consecutive series of 250 deceased individuals who were computerized tomography (CT)-scanned and autopsied. In 13% of patients, important findings at the CT-scanning were not found at the autopsy, and in 48% of patients, important autopsy findings were not...... and allows fractures and inner organs to be seen "in situ." CT provides documentation in digital form - easily stored - permits review by others and provides pictures that may be more suitable for presentation in court than autopsy photos....

  5. Two-Phase Flow Regime Identification by Ultrasonic Computerized Tomography

    Directory of Open Access Journals (Sweden)

    Mohd Hafiz FAZALUL RAHIMAN

    2010-05-01

    Full Text Available This paper describes the development of ultrasonic computerized tomography for identifying the liquid and gas flow regimes. The work reported in this paper demonstrates image reconstruction techniques applied to an experimental vessel using non-invasive technique. The investigations were based on the transmission and the reception of ultrasonic sensors that were mounted circularly on the surface of an experimental vessel. The algorithms used to reconstruct the concentration profile for two-phase flow using fan-shaped beam scanning geometry were also presented.

  6. Correlation between high-resolution computed tomography and surgical findings in congenital aural atresia.

    Science.gov (United States)

    Mehra, Y N; Dubey, S P; Mann, S B; Suri, S

    1988-02-01

    Congenital aural atresia poses a great challenge, even to a competent otologic surgeon, due to innumerable types of malformations affecting the conduction and perception of sound. Roentgenographic evaluation by plain roentgenography is inconclusive in most cases; polytomography is helping to some extent. Recent generations of high-resolution computed tomographic (CT) scanners are probably the best. Seven cases of unilateral and three cases of bilateral congenital aural atresia were evaluated with high-resolution CT. Subsequently, ten ears were operated on. Surgical findings were correlated with CT scan findings with respect to atresia plate, extent of pneumatization, ossicular anomalies, bony facial nerve canal, and inner ear. Use of CT scans bears considerable importance in the management of these types of cases. High-resolution CT scan, when targeted for maximal bony detail, is possibly the method of choice in congenital aural atresia when surgical correction is contemplated.

  7. Lung mechanics and high-resolution computed tomography of the chest in very low birth weight premature infants

    Directory of Open Access Journals (Sweden)

    Rosane Reis de Mello

    Full Text Available CONTEXT: Premature infant lung development may be affected by lung injuries during the first few weeks of life. Lung injuries have been associated with changes in lung mechanics. OBJECTIVE: To evaluate an association between lung mechanics and lung structural alterations in very low birth weight infants (birth weight less than 1500 g. DESIGN: A cross-sectional evaluation of pulmonary mechanics (lung compliance and lung resistance and high resolution computed tomography of the chest at the time of discharge, in 86 very low birth weight infants born at Instituto Fernandes Figueira, a tertiary public healthcare institution in Rio de Janeiro, Brazil. Lung compliance and resistance were measured during quiet sleep. High resolution computed tomography was performed using Pro Speed-S equipment. MAIN MEASUREMENTS: Statistical analysis was performed by means of variance analysis (ANOVA/ Kruskal Wallis. The significance level was set at 0.05. RESULTS: Abnormal values for both lung compliance and lung resistance were found in 34 babies (43%, whereas 20 (23.3% had normal values for both lung compliance and lung resistance. The mean lung compliance and lung resistance for the group were respectively 1.30 ml/cm H2O/kg and 63.7 cm H2O/l/s. Lung alterations were found via high-resolution computed tomography in 62 (72% infants. Most infants showed more than one abnormality, and these were described as ground glass opacity, parenchymal bands, atelectasis and bubble/cyst. The mean compliance values for infants with normal (1.49 ml/cm H2O/kg high resolution computed tomography, 1 or 2 abnormalities (1.31 ml/cm H2O/kg and 3 or more abnormalities (1.16 ml/cm H2O/kg were significantly different (p = 0.015. Our data were insufficient to find any association between lung resistance and the number of alterations via high-resolution computed tomography. CONCLUSION: The results show high prevalence of lung functional and tomographic abnormalities in asymptomatic very low

  8. Findings of psychopathology and computerized tomography in neuropsychiatric diseases

    Energy Technology Data Exchange (ETDEWEB)

    Gross, G.; Huber, G.; Schuettler, R.

    1982-08-01

    1978-1980 we examined 451 patients of the Psychiatric University Clinic of Bonn by computerized tomography. From 260 patients with characterized diseases of the brain and brain damages, 78 patients had neuropsychiatric diseases of old age, i.e. cerebro-vascular processes (average age of 63.7 years) and 9 patients had primary degenerative processes of the brain (average age of 62.1 years). Patients with diseases of the cerebral vessels showed irreversible psychopathological syndromes in 87%. The rate of pathological findings in CT increases in relation to degree of severity of the chronic (irreversible) organic psychosyndromes from 76% in pseudoneurasthenics syndromes to 93% in patients with organic changes of personality and to 100% in patients with dementia. The ambiguity of the conception of the multi-infarct-dementia is discussed. Only 19% of the sample with irreversible psychopathological changes showed localized neurological deficits and infarctions in CT, but none of them more than one. In all patients with dementia a cortical atrophy was found. There is a significant positive correlation between cerebral atrophy in CT and irreversible organic psychosyndrome. These findings with computerized tomography demonstrate in accordance with earlier pneumoencephalographic findings that distinct types of irreversible psychosyndromes can be correlated to distinct types of cerebral atrophy. But these statistical correlations between the degree of the severity of the loss of psychic functions and the reduction of cerebral tissue are not necessarily valid for any single case.

  9. Application of computerized tomography to the investigation of ionospheric structures

    Energy Technology Data Exchange (ETDEWEB)

    Raymund, T.D.; Austen, J.R.; Franke, S.J.; Liu, C.H.; Klobuchar, J.A.

    1990-10-01

    Ionospheric total electron content (TEC) measurements, obtained simultaneously at several locations, can be processed using computerized tomography (CT) algorithms to obtain two-dimensional images of ionospheric electron density. Using TEC data computerized ionospheric tomography (CIT) reconstructs an image of the electron density structures in a vertical slice above the receiving stations. We successfully applied this technique to realistic simulations of ionospheric density variations over 16 degree of latitude and a height range of 50 to 1000 km. A method for approximating the peak height and scale height of the electron density profile will be discussed as well as a reconstruction technique based on the multiplicative algebraic reconstruction technique algorithm and a back projection based initial guess. The quality of reconstructions is considered for two geometries and image resolutions. In particular, the image of a mid-latitude trough with background horizontal density gradient and large-scale irregular structures has been reconstructed from TEC data generated from a model based on an incoherent scatter radar observation. The CT reconstructed image was compared with the original contour map obtained by the incoherent scatter radar. Good agreement has been achieved. The CIT technique has also been applied to a modeled ionosphere to calculate the range rate corrections for a Doppler-tracking radar. Reprint

  10. Diagnosis and management of conjunctival and corneal intraepithelial neoplasia using ultra high-resolution optical coherence tomography.

    Science.gov (United States)

    Shousha, Mohamed Abou; Karp, Carol L; Perez, Victor L; Hoffmann, Rodrigo; Ventura, Roberta; Chang, Victoria; Dubovy, Sander R; Wang, Jianhua

    2011-08-01

    To report a novel diagnostic technique and a case series of conjunctival and corneal intraepithelial neoplasia (CCIN) diagnosed and followed up using prototype ultra high-resolution (UHR) optical coherence tomography (OCT). Prospective, noncomparative, interventional case series. Seven eyes of 7 consecutive patients with CCIN treated using topical interferon alfa-2b or 5-fluorouracil and 7 eyes of 6 consecutive patients with history of surgically excised pterygia. Ultra high-resolution OCT imaging of the ocular surface at primary diagnosis of CCIN and during the follow-up period until resolution of the lesion. Ultra high-resolution OCT images of sites of excised pterygia also were captured and compared with images from resolved CCIN patients. Clinical course and photographs, UHR OCT images, and histopathologic findings. Ultra high-resolution OCT was capable of providing a noninvasive optical biopsy of all examined CCIN lesions. Ultra high-resolution OCT images of the lesions disclosed a thickened hyperreflective epithelium and abrupt transition from normal to hyperreflective epithelium in all 7 cases. Ultra high-resolution OCT images showed excellent correlation with histopathologic specimens obtained at primary diagnosis of the cases that had incisional biopsies before treatment. All patients were treated medically and were followed up for clinical resolution. In 4 patients, at clinical resolution, UHR OCT images also showed normal epithelial configuration at the site of the treated lesions. In 3 patients, despite apparent clinical resolution, the UHR OCT was able to detect residual disease that was clinically invisible. Continuation of treatment resulted in complete resolution of the residual lesions on the UHR OCT images in all cases. Ultra high-resolution OCT images of patients with surgically excised pterygia demonstrated similar findings to resolved CCIN cases. Ultra high-resolution OCT is a novel noninvasive technique to diagnose and manage medically treated

  11. Differential diagnosis in computerized tomography. 2. rev. and enl. ed.; Differenzialdiagnosen in der Computertomografie

    Energy Technology Data Exchange (ETDEWEB)

    Burgener, Francis A.; Meyers, Steven P. [Rochester Univ., NY (United States). Dept. of Imaging Sciences; Herzog, Christopher [Rotkreuzklinikum Muenchen (Germany); Zaunbauer, Wolfgang [Kantonsspital St. Gallen (Switzerland). Inst. fuer Radiologie

    2013-02-01

    The book on differential diagnosis in computerized tomography is aimed to support radiologists and physicians with experience concerning the interpretation of computerized tomography images by detailed descriptions of CT diagnoses. The book covers the following topics: intracranial indications, head and neck, spinal cord, muscle-skeleton system, thorax, abdomen and pelvis.

  12. High-Resolution Multispectral Optoacoustic Tomography of the Vascularization and Constitutive Hypoxemia of Cancerous Tumors

    Directory of Open Access Journals (Sweden)

    Andrei Chekkoury

    2016-08-01

    Full Text Available Diversity of the design and alignment of illumination and ultrasonic transducers empower the fine scalability and versatility of optoacoustic imaging. In this study, we implement an innovative high-resolution optoacoustic mesoscopy for imaging the vasculature and tissue oxygenation within subcutaneous and orthotopic cancerous implants of mice in vivo through acquisition of tomographic projections over 180° at a central frequency of 24 MHz. High-resolution volumetric imaging was combined with multispectral functional measurements to resolve the exquisite inner structure and vascularization of the entire tumor mass using endogenous and exogenous optoacoustic contrast. Evidence is presented for constitutive hypoxemia within the carcinogenic tissue through analysis of the hemoglobin absorption spectra and distribution. Morphometric readouts obtained with optoacoustic mesoscopy have been verified with high-resolution ultramicroscopic studies. The findings described herein greatly extend the applications of optoacoustic mesoscopy toward structural and multispectral functional measurements of the vascularization and hemodynamics within solid tumors in vivo and are of major relevance to basic and preclinical oncological studies in small animal models.

  13. Determining Metacarpophalangeal Flexion Angle Tolerance for Reliable Volumetric Joint Space Measurements by High-resolution Peripheral Quantitative Computed Tomography.

    Science.gov (United States)

    Tom, Stephanie; Frayne, Mark; Manske, Sarah L; Burghardt, Andrew J; Stok, Kathryn S; Boyd, Steven K; Barnabe, Cheryl

    2016-10-01

    The position-dependence of a method to measure the joint space of metacarpophalangeal (MCP) joints using high-resolution peripheral quantitative computed tomography (HR-pQCT) was studied. Cadaveric MCP were imaged at 7 flexion angles between 0 and 30 degrees. The variability in reproducibility for mean, minimum, and maximum joint space widths and volume measurements was calculated for increasing degrees of flexion. Root mean square coefficient of variance values were spaces. Values for minimum joint space width were optimized under 10 degrees of flexion. MCP joint space measurements should be acquired at < 10 degrees of flexion in longitudinal studies.

  14. Assessment of computerized tomography devices in Minas Gerais state, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Paulo Marcio C., E-mail: pmco@cdtn.br, E-mail: ambienttal@ambienttal.com.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Horta, Mara Alice Avelar Saraiva [Faculdade Sao Camilo de Minas Gerais - FASC - MG, Graduacao de Tecnologia em Radiologia (Brazil); Santana, Priscila do Carmo [Programa de Pos Graduacao em Ciencias e Tecnicas Nucleares - PCTN, Universidade Federal de Minas Gerais (UFMG) Belo Horizonte, MG (Brazil); Magalhaes, Marcos Juliano [Ambienttal Protecao Radiologica Ltda., Belo Horizonte, MG (Brazil)

    2011-07-01

    Computed Tomography (CT) is the diagnostic imaging method most commonly performed today. It is a device that is undergoing a technological evolution and their quality control is sorely needed. The image quality evaluation process allow a better diagnosis and control of the patient dose received during image acquisition. The CT doses are higher than other X-ray examination techniques, like a conventional X-ray. Performance evaluation of computed tomography in Minas Gerais is not significant. Therefore, this work aims to analyze 20 CT equipment in Minas Gerais, with parameters according to the national regulatory agency (ANVISA - Agencia Nacional de Vigilancia Sanitaria) in twelve quality control tests. Sixty five percent (65%) of CT equipment evaluated showed excellent results and were not disapproved in any of the tests performed and 30% had failed in only one of the twelve tests performed. The worst result was found in the CT scanners in the test that evaluates the low contrast resolution, where 20% of CT showed non-compliance, followed by the test that evaluates the x-rays collimation beam, where 15% had failed. The tests allowed us to observe that the twenty computerized tomography equipment achieved a great pass rate. Considering that the evaluated CTs performed the quality control tests for the first time, it is concluded that the equipment used in clinics and hospitals are of good quality image and low radiation doses. (author)

  15. Current concepts and advances: computerized tomography in sports medicine.

    Science.gov (United States)

    Buckwalter, Kenneth A

    2009-03-01

    Computed tomography (CT) is a widely used imaging technique. With the introduction of multidetector row technology, CT has been further refined. Although the focus of this transformation has been body and cardiac imaging, orthopedic imaging has benefited greatly. Specifically, the improvements in CT have made it possible to obtain submillimeter-thick slices that enable the creation of high-resolution multiplanar reformations from a single scan. These images usually are indistinguishable from direct plane acquisitions and provide unparalleled detail. Additionally, the factors responsible for causing CT image artifacts when hardware is present are much better understood and the improvements in CT technique and technology can be exploited to provide better images of patients with orthopedic hardware. The detailed multiplanar visualization of joints facilitates CT arthrography that has undergone a renaissance. CT arthrography is useful in the very large athlete or patient, the claustrophobic, and for those patients who fail a conventional magnetic resonance examination or magnetic resonance arthrogram.

  16. Retinal structure of birds of prey revealed by ultra-high resolution spectral-domain optical coherence tomography.

    Science.gov (United States)

    Ruggeri, Marco; Major, James C; McKeown, Craig; Knighton, Robert W; Puliafito, Carmen A; Jiao, Shuliang

    2010-11-01

    To reveal three-dimensional (3-D) information about the retinal structures of birds of prey in vivo. An ultra-high resolution spectral-domain optical coherence tomography (SD-OCT) system was built for in vivo imaging of retinas of birds of prey. The calibrated imaging depth and axial resolution of the system were 3.1 mm and 2.8 μm (in tissue), respectively. 3-D segmentation was performed for calculation of the retinal nerve fiber layer (RNFL) map. High-resolution OCT images were obtained of the retinas of four species of birds of prey: two diurnal hawks (Buteo platypterus and Buteo brachyurus) and two nocturnal owls (Bubo virginianus and Strix varia). These images showed the detailed retinal anatomy, including the retinal layers and the structure of the deep and shallow foveae. The calculated thickness map showed the RNFL distribution. Traumatic injury to one bird's retina was also successfully imaged. Ultra-high resolution SD-OCT provides unprecedented high-quality 2-D and 3-D in vivo visualization of the retinal structures of birds of prey. SD-OCT is a powerful imaging tool for vision research in birds of prey.

  17. High-resolution coded-aperture design for compressive X-ray tomography using low resolution detectors

    Science.gov (United States)

    Mojica, Edson; Pertuz, Said; Arguello, Henry

    2017-12-01

    One of the main challenges in Computed Tomography (CT) is obtaining accurate reconstructions of the imaged object while keeping a low radiation dose in the acquisition process. In order to solve this problem, several researchers have proposed the use of compressed sensing for reducing the amount of measurements required to perform CT. This paper tackles the problem of designing high-resolution coded apertures for compressed sensing computed tomography. In contrast to previous approaches, we aim at designing apertures to be used with low-resolution detectors in order to achieve super-resolution. The proposed method iteratively improves random coded apertures using a gradient descent algorithm subject to constraints in the coherence and homogeneity of the compressive sensing matrix induced by the coded aperture. Experiments with different test sets show consistent results for different transmittances, number of shots and super-resolution factors.

  18. Analysis of the mental foramen using cone beam computerized tomography

    Directory of Open Access Journals (Sweden)

    Kunihiro Saito

    Full Text Available AbstractIntroductionKnowledge of the anatomical structures located in the region between the mental foramina is of critical importance in pre-operative planning.ObjectiveTo evaluate the position of the mental foramen relative to the apices of the teeth and the distance to the edges of the mandible, using cone beam computerized tomography.Material and methodOne hundred cone beam computerized tomographs of the mandible were evaluated; the tomographs were taken using a single tomographic device. Each image chosen was evaluated repeatedly from both sides of the mandible, the position of the mental foramen, indicating the region in which the foramen was found and the measures of the mental foramen, the lingual cortex and the mandibular base. Initially, the data were analyzed descriptively. A value of pResultForty-two percent of the mental foramina were located in the apex of the second pre-molar. The lingual margin of the mental foramen was located, on average, 3.1mm from the lingual cortex. The lower margin of the mental foramen was located 7.25 mm above the lower edge of the mandible.ConclusionThe mental foramen was located more frequently at a level of the apices of the second pre-molars, with a distance to the lingual cortex, on average, of 3.1mm and to the base of the mandible, on average, of 7.25 mm.

  19. Computerized Tomography with Total Variation and with Shearlets

    CERN Document Server

    Garduño, Edgar

    2016-01-01

    To reduce the x-ray dose in computerized tomography (CT), many constrained optimization approaches have been proposed aiming at minimizing a regularizing function that measures lack of consistency with some prior knowledge about the object that is being imaged, subject to a (predetermined) level of consistency with the detected attenuation of x-rays. Proponents of the shearlet transform in the regularizing function claim that the reconstructions so obtained are better than those produced using TV for texture preservation (but may be worse for noise reduction). In this paper we report results related to this claim. In our reported experiments using simulated CT data collection of the head, reconstructions whose shearlet transform has a small $\\ell_1$-norm are not more efficacious than reconstructions that have a small TV value. Our experiments for making such comparisons use the recently-developed superiorization methodology for both regularizing functions. Superiorization is an automated procedure for turning...

  20. Motion Estimation and Compensation Strategies in Dynamic Computerized Tomography

    Science.gov (United States)

    Hahn, Bernadette N.

    2017-12-01

    A main challenge in computerized tomography consists in imaging moving objects. Temporal changes during the measuring process lead to inconsistent data sets, and applying standard reconstruction techniques causes motion artefacts which can severely impose a reliable diagnostics. Therefore, novel reconstruction techniques are required which compensate for the dynamic behavior. This article builds on recent results from a microlocal analysis of the dynamic setting, which enable us to formulate efficient analytic motion compensation algorithms for contour extraction. Since these methods require information about the dynamic behavior, we further introduce a motion estimation approach which determines parameters of affine and certain non-affine deformations directly from measured motion-corrupted Radon-data. Our methods are illustrated with numerical examples for both types of motion.

  1. Application of computerized tomography to the investigation of ionospheric structures

    Energy Technology Data Exchange (ETDEWEB)

    Raymund, T.D.; Franke, S.J.; Liu, C.H.; Austen, J.R.; Klobuchar, J.A. (Illinois Univ., Urbana (USA) Tennessee Technological Univ., Cookeville (USA) USAF, Geophysics Laboratory, Hanscom AFB, MA (USA))

    1990-10-01

    It is shown that ionospheric total electron content measurements, obtained simultaneously at several locations, can be processed using computerized tomography (CT) algorithms to obtain two-dimensional images of ionospheric electron density. CT, using ionospheric total electron content data, is applied to simulate density variations over 16 deg of latitude and a height range of 50 to 1000 km. A method of approximating the peak height and scale height of the electron density profile is presented, as well as a reconstruction technique using a multiplicative algebraic algorithm and a back projection based initial guess. The quality of the images is examined for two geometries and resolutions. It is suggested that the reconstruction algorithm is sufficiently robust to perform well even in the presence of broad-band noise of reasonable level. 12 refs.

  2. High resolution feature extraction from optical coherence tomography acquired internal fingerprint

    CSIR Research Space (South Africa)

    Khutlang, Rethabile

    2016-05-01

    Full Text Available coherence tomography (OCT) can be used to scan the internal skin features, up to the depth of the papillary layer. OCT is contactless and scans in three dimensions. The papillary contour represents an internal fingerprint, which does not suffer external skin...

  3. Individual integration of positron emission tomography and high-resolution magnetic resonance imaging.

    Science.gov (United States)

    Steinmetz, H; Huang, Y; Seitz, R J; Knorr, U; Schlaug, G; Herzog, H; Hackländer, T; Freund, H J

    1992-11-01

    We have developed, validated, and employed a technique of retrospective spatial alignment and integrated display of positron emission tomographic (PET) and high-resolution magnetic resonance (MR) brain images. The method was designed to improve the anatomical evaluation of functional images obtained from single subjects. In the first computational step, alignment of PET and MR data sets is achieved by iteratively matching in three orthogonal views the outermost scalp contours derived from front-to-back projections of each data set. This procedure avoids true three-dimensional modeling, runs without user interaction, and tolerates missing parts of the head circumference in the image volume, as usually the case with PET. Thereafter, high-resolution MR sections corresponding to the PET slices are reconstructed from the spatially transformed MR data. In a phantom study of this method, PET/MR alignment of the phantom's surface was accurate with average residual misfits of 2.17 to 2.32 mm as determined in three orthogonal planes. In-plane alignment of the phantom's insertion holes was accurate with an average residual misfit of 2.30 mm. In vivo application in six subjects allowed the individual anatomical localization of regional CBF (rCBF) responses obtained during unilateral manual exploration. In each subject, the maxima of the rCBF activations in the hand area were precisely allocated to gray matter in the anterior or posterior wall of the central sulcus. The configuration of the rCBF responses closely followed the gyral structures. The technique provided a better topographical understanding of rCBF changes in subtraction images of PET activation studies. It opens the perspective for studies of structural-functional relationships in individual subjects.

  4. High resolution tomography of objects with access to a single side

    Energy Technology Data Exchange (ETDEWEB)

    Thoe, R.S.

    1993-03-24

    The author is developing a technique which will enable one to obtain high-contrast, high-spatial resolution, three-dimensional images in opaque objects. The only constraint will be the radiation source and detector(s) will be located on the same side of the object. The goal is to obtain images with a spatial resolution of {approximately}1 mm at depths of 10 mm and {approximately}3 mm at depths of 30 mm in materials of moderate density (brass, steel, etc.). The author`s technique uses a highly-collimated beam of monochromatic gamma rays and a slit collimated high-resolution, high-efficiency, coaxial germanium spectrometer. If the geometry is well known, the spectrum of Compton scattered radiation can be used to map out the density as a function of depth. By scanning the object in two dimensions, a full three-dimensional image of the electron density can be reconstructed. The resolution is dependent on the incident beam collimation and the energy resolution of the spectrometer. For his system, the author anticipates a resolution of about 1 mm{sup 3}. The apparatus, reconstruction algorithms and current data verifying his predictions are presented here. Also included are the details on how the system can be modified to increase the efficiency by over two orders of magnitude. This system will have several advantages over conventional transmission radiographic and tomographic systems: (1) It requires the use of a high specific intensity isotopic source of modest activity (< 100 mCi). (2) It requires only a single high-resolution spectrometer used in conjunction with an array of low-resolution detectors (all readily available). (3) It allows for the recording of three-dimensional images of object even though both detector and source are located on the same side of the object.

  5. Geophysical diffraction tomography and waveform inversion: Applications to high resolution seismic data

    Science.gov (United States)

    Gao, F.; Shen, P.; Symes, W. W.; Zelt, C. A.; Levander, A.

    2001-12-01

    We apply two different techniques to analyze high resolution seismic data from surface and borehole measurements made at a groundwater contamination site at Hill Air Force Base, Ogden, Utah. Two vertical seismic profiles and surface data were recorded simultaneously in and between two 15m deep boreholes separated by 21m. The seismic source was a 223 rifle fired on the surface between the two boreholes, generating signals with energy up to ~300Hz. The size of the target area is roughly the order of a few mean wavelengths in the dataset. The relatively large ratio of mean wavelength ( ~5m) to the scale of structural detail in this high-resolution experiment (projecting misfits in the data space into velocity corrections in the model space. In theory, multiple-frequencies and non-uniform data sampling can be handled easily. In the second technique, full waveform inversion, the inverse problem is posed as nonlinear data fitting where the unknown parameters are solved by minimizing the misfit between the predicted data and the observed data. A gradient-type approach is applied to solve these problems in which the Jacobian and its adjoint are calculated for given model and data vectors. We present an explicit finite difference time stepping scheme to compute the forward model and its adjoint. Waveform data fitting driven by finite difference simulations can be based on different physical modeling assumptions, from acoustic to viscoelastic propagation. Our finite difference class defines an operator in the sense of the Hilbert Class Library (HCL), a C++ software package for optimization (Cockenback, and Symes, 1996). A wide range of gradient type inversion algorithms using HCL as a platform can be tested.

  6. Development of high-resolution detector module with depth of interaction identification for positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Niknejad, Tahereh, E-mail: tniknejad@lip.pt [Laboratory of Instrumentation and Experimental Particles Physics, Lisbon (Portugal); Pizzichemi, Marco [University of Milano-Bicocca (Italy); Stringhini, Gianluca [University of Milano-Bicocca (Italy); CERN, Geneve (Switzerland); Auffray, Etiennette [CERN, Geneve (Switzerland); Bugalho, Ricardo; Da Silva, Jose Carlos; Di Francesco, Agostino [Laboratory of Instrumentation and Experimental Particles Physics, Lisbon (Portugal); Ferramacho, Luis [PETsys Electronics, Oeiras (Portugal); Lecoq, Paul [CERN, Geneve (Switzerland); Leong, Carlos [PETsys Electronics, Oeiras (Portugal); Paganoni, Marco [University of Milano-Bicocca (Italy); Rolo, Manuel [Laboratory of Instrumentation and Experimental Particles Physics, Lisbon (Portugal); INFN, Turin (Italy); Silva, Rui [Laboratory of Instrumentation and Experimental Particles Physics, Lisbon (Portugal); Silveira, Miguel [PETsys Electronics, Oeiras (Portugal); Tavernier, Stefaan [PETsys Electronics, Oeiras (Portugal); Vrije Universiteit Brussel (Belgium); Varela, Joao [Laboratory of Instrumentation and Experimental Particles Physics, Lisbon (Portugal); CERN, Geneve (Switzerland); Zorraquino, Carlos [Biomedical Image Technologies Lab, Universidad Politécnica de Madrid (Spain); CIBER-BBN, Universidad Politécnica de Madrid (Spain)

    2017-02-11

    We have developed a Time-of-flight high resolution and commercially viable detector module for the application in small PET scanners. A new approach to depth of interaction (DOI) encoding with low complexity for a pixelated crystal array using a single side readout and 4-to-1 coupling between scintillators and photodetectors was investigated. In this method the DOI information is estimated using the light sharing technique. The detector module is a 1.53×1.53×15 mm{sup 3} matrix of 8×8 LYSO scintillator with lateral surfaces optically depolished separated by reflective foils. The crystal array is optically coupled to 4×4 silicon photomultipliers (SiPM) array and readout by a high performance front-end ASIC with TDC capability (50 ps time binning). The results show an excellent crystal identification for all the scintillators in the matrix, a timing resolution of 530 ps, an average DOI resolution of 5.17 mm FWHM and an average energy resolution of 18.29% FWHM. - Highlights: • A new method for DOI encoding for PET detectors based on light sharing is proposed. • A prototype module with LYSO scintillator matrix coupled to SiPMs array is produced. • The module has one side readout and 4-to-1 coupling between scintillators and SiPMs. • A compact TOF front-end ASIC is used. • Excellent performances are shown by the prototype module.

  7. Comparison of high-resolution computed tomography findings between Pseudomonas aeruginosa pneumonia and Cytomegalovirus pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Omeri, Ahmad Khalid; Okada, Fumito; Takata, Shoko; Ono, Asami; Sato, Haruka; Mori, Hiromu [Oita University Faculty of Medicine, Department of Radiology, Yufu, Oita (Japan); Nakayama, Tomoko [Oita Red Cross Hospital, Department of Radiology, Oita (Japan); Ando, Yumiko [Oita Nishibeppu National Hospital, Department of Radiology, Oita (Japan); Hiramatsu, Kazufumi [Oita University Hospital, Hospital Infection Control Center, Oita (Japan)

    2014-12-15

    To compare pulmonary high-resolution CT (HRCT) findings in patients with Pseudomonas aeruginosa pneumonia to HRCT findings in patients with Cytomegalovirus (CMV) pneumonia. We studied 124 patients (77 men, 47 women; age range, 20-89 years; mean age, 65.4 years) with P. aeruginosa pneumonia and 44 patients (22 men, 22 women; age range, 36-86 years; mean age, 63.2 years) with CMV pneumonia. CT findings of consolidation (p < 0.005), bronchial wall thickening (p < 0.001), cavity (p < 0.05), and pleural effusion (p < 0.001) were significantly more frequent in patients with P. aeruginosa pneumonia than in those with CMV pneumonia. Centrilobular nodules, a crazy-paving appearance, and nodules were significantly more frequent in patients with CMV pneumonia than in those with P. aeruginosa pneumonia (all p < 0.001). Pulmonary HRCT findings, such as bronchial wall thickening, crazy-paving appearance, and nodules may be useful in distinguishing between P. aeruginosa pneumonia and CMV pneumonia. (orig.)

  8. High-resolution synchrotron radiation-based phase tomography of the healthy and epileptic brain

    Science.gov (United States)

    Bikis, Christos; Janz, Philipp; Schulz, Georg; Schweighauser, Gabriel; Hench, Jürgen; Thalmann, Peter; Deyhle, Hans; Chicherova, Natalia; Rack, Alexander; Khimchenko, Anna; Hieber, Simone E.; Mariani, Luigi; Haas, Carola A.; Müller, Bert

    2016-10-01

    Phase-contrast micro-tomography using synchrotron radiation has yielded superior soft tissue visualization down to the sub-cellular level. The isotropic spatial resolution down to about one micron is comparable to the one of histology. The methods, however, provide different physical quantities and are thus complementary, also allowing for the extension of histology into the third dimension. To prepare for cross-sectional animal studies on epilepsy, we have standardized the specimen's preparation and scanning procedure for mouse brains, so that subsequent histology remains entirely unaffected and scanning of all samples (n = 28) is possible in a realistic time frame. For that, we have scanned five healthy and epileptic mouse brains at the ID19 beamline, ESRF, Grenoble, France, using grating- and propagation-based phase contrast micro-tomography. The resulting datasets clearly show the cortex, ventricular system, thalamus, hypothalamus, and hippocampus. Our focus is on the latter, having planned kainate-induced epilepsy experiments. The cell density and organization in the dentate gyrus and Ammon's horn region were clearly visualized in control animals. This proof of principle was required to initiate experiment. The resulting three-dimensional data have been correlated to histology. The goal is a brain-wide quantification of cell death or structural reorganization associated with epilepsy as opposed to histology alone that represents small volumes of the total brain only. Thus, the proposed technique bears the potential to correlate the gold standard in analysis with independently obtained data sets. Such an achievement also fuels interest for other groups in neuroscience research to closely collaborate with experts in phase micro-tomography.

  9. High-resolution retinal imaging using adaptive optics and Fourier-domain optical coherence tomography

    Science.gov (United States)

    Olivier, Scot S.; Werner, John S.; Zawadzki, Robert J.; Laut, Sophie P.; Jones, Steven M.

    2010-09-07

    This invention permits retinal images to be acquired at high speed and with unprecedented resolution in three dimensions (4.times.4.times.6 .mu.m). The instrument achieves high lateral resolution by using adaptive optics to correct optical aberrations of the human eye in real time. High axial resolution and high speed are made possible by the use of Fourier-domain optical coherence tomography. Using this system, we have demonstrated the ability to image microscopic blood vessels and the cone photoreceptor mosaic.

  10. Tracking Solid Oxide Cell Microstructure Evolution by High Resolution 3D Nano-Tomography

    DEFF Research Database (Denmark)

    De Angelis, Salvatore

    Solid oxide cells (SOCs) oer great prospects for the ecient and reversible conversion of chemical to electrical energy. Therefore, they are expected to play a key role in the renewable energy landscape. However, their limited lifetime under operating conditions hinders their widespread usage...... tomography is applied. Preliminary results show rapid kinetics for the two reactions. During oxidation, void formation in metallic particles is observed. During reduction, the nickel oxide particles rst evolve to a nano-porous system of nickel crystallites and then coarsen towards dense nickel particles....

  11. Ultra-high resolution optical coherence tomography analysis of bull's eye maculopathy in chloroquine users

    Directory of Open Access Journals (Sweden)

    Celso Morita

    2014-06-01

    Full Text Available Purpose: Register and compare anatomical changes, structural and quantitative found in optical coherence tomography Stratus and Topcon 3D in chronic users of chloroquine. Methods: Five patients were diagnosed with toxic "bull's eye" maculopathy was submitted to macular optical coherence tomography examination (Stratus and Topcon 3D. Results: Both tools demonstrated an increase reflectivity of choriocapillaris unit just foveal retinal pigment epithelium atrophy. However, Topcon 3D provided to all patients better description of the line corresponding to the transition between inner and outer segments of photoreceptors. Using the possibility of assembling threedimensional images and subtraction selective retinal layers, we found a lesion with a target that reflects the greater thickness of retinal pigment epithelium in central and parafoveal region that is matched to preserve macular photoreceptors. Conclusion: it was observed better resolution and faster image capture by Topcon 3D than Stratus OCT, that provided more detailed analysis of the line corresponding to transition between outer and inner segment of photoreceptors in macular region. With Topcon 3D, it was possible to evaluate soundly the thickness of retinal pigment epithelium in central and parafoveal region that caused an increase reflectivity of choriocapillaris creating a image with a target unpublished before.

  12. High-resolution optical coherence tomography, autofluorescence, and infrared reflectance imaging in Sjögren reticular dystrophy.

    Science.gov (United States)

    Schauwvlieghe, Pieter-Paul; Torre, Kara Della; Coppieters, Frauke; Van Hoey, Anneleen; De Baere, Elfride; De Zaeytijd, Julie; Leroy, Bart P; Brodie, Scott E

    2013-01-01

    To describe the phenotype of three cases of Sjögren reticular dystrophy in detail, including high-resolution optical coherence tomography, autofluorescence imaging, and near-infrared reflectance imaging. Two unrelated teenagers were independently referred for ophthalmologic evaluation. Both underwent a full ophthalmologic workup, including electrophysiologic and extensive imaging with spectral-domain optical coherence tomography, autofluorescence imaging, and near-infrared reflectance imaging. In addition, mutation screening of ABCA4, PRPH2, and the mitochondrial tRNA gene was performed in Patient 1. Subsequently, the teenage sister of Patient 2 was examined. Strikingly similar phenotypes were present in these three patients. Fundoscopy showed bilateral foveal pigment alterations, and a lobular network of deep retinal, pigmented deposits throughout the posterior pole, tapering toward the midperiphery, with relative sparing of the immediate perifoveal macula and peripapillary area. This network is mildly to moderately hyperautofluorescent on autofluorescence and bright on near-infrared reflectance imaging. Optical coherence tomography showed abnormalities of the retinal pigment epithelium-Bruch membrane complex, photoreceptor outer segments, and photoreceptor inner/outer segment interface. The results of retinal function test were entirely normal. No molecular cause was detected in Patient 1. Imaging suggested that the lobular network of deep retinal deposits in Sjögren reticular dystrophy is the result of accumulation of both pigment and lipofuscin between photoreceptors and retinal pigment epithelium, as well as within the retinal pigment epithelium.

  13. Dual-modal three-dimensional imaging of single cells with isometric high resolution using an optical projection tomography microscope.

    Science.gov (United States)

    Miao, Qin; Rahn, J Richard; Tourovskaia, Anna; Meyer, Michael G; Neumann, Thomas; Nelson, Alan C; Seibel, Eric J

    2009-01-01

    The practice of clinical cytology relies on bright-field microscopy using absorption dyes like hematoxylin and eosin in the transmission mode, while the practice of research microscopy relies on fluorescence microscopy in the epi-illumination mode. The optical projection tomography microscope is an optical microscope that can generate 3-D images of single cells with isometric high resolution both in absorption and fluorescence mode. Although the depth of field of the microscope objective is in the submicron range, it can be extended by scanning the objective's focal plane. The extended depth of field image is similar to a projection in a conventional x-ray computed tomography. Cells suspended in optical gel flow through a custom-designed microcapillary. Multiple pseudoprojection images are taken by rotating the microcapillary. After these pseudoprojection images are further aligned, computed tomography methods are applied to create 3-D reconstruction. 3-D reconstructed images of single cells are shown in both absorption and fluorescence mode. Fluorescence spatial resolution is measured at 0.35 microm in both axial and lateral dimensions. Since fluorescence and absorption images are taken in two different rotations, mechanical error may cause misalignment of 3-D images. This mechanical error is estimated to be within the resolution of the system.

  14. Potentials of high resolution magnetic resonance imaging versus computed tomography for preoperative local staging of colon cancer

    Energy Technology Data Exchange (ETDEWEB)

    Rollven, Erik; Blomqvist, Lennart [Dept. of Diagnostic Radiology, Karolinska Univ. Hospital Solna, Stockholm (Sweden); Dept. of Molecular Medicine and Surgery, Karolinska Inst., Stockholm (Sweden)], e-mail: erik.rollven@ki.se; Holm, Torbjorn [Dept. of Molecular Medicine and Surgery, Karolinska Inst., Stockholm (Sweden); Dept. of Surgery, Karolinska Univ. Hospital Solna, Stockholm (Sweden); Glimelius, Bengt [Dept. of Radiology, Oncology and Radiation Science, Uppsala Univ., Uppsala (Sweden); Dept. of Oncology and Pathology, Karolinska Inst., Stockholm (Sweden); Loerinc, Esther [Dept. of Oncology and Pathology, Karolinska Inst., Stockholm (Sweden); Dept. of Pathology, Karolinska Univ. Hospital, Solna, Sweden (Sweden)

    2013-09-15

    Background: Preoperative identification of locally advanced colon cancer is of importance in order to properly plan treatment. Purpose: To study high resolution T2-weighted magnetic resonance imaging (MRI) versus computed tomography (CT) for preoperative staging of colon cancer with surgery and histopathology as reference standard. Material and Methods: Twenty-eight patients with a total of 29 tumors were included. Patients were examined on a 1.5 T MR unit using a phased array body coil. T2 turbo spin-echo high resolution sequences were obtained in a coronal, transverse, and perpendicular plane to the long axis of the colon at the site of the tumor. Contrast-enhanced CT was performed using a protocol for metastasis staging. The examinations were independently evaluated by two gastrointestinal radiologists using criteria adapted to imaging for prediction of T-stage, N-stage, and extramural venous invasion. Based on the T-stage, tumors were divided in to locally advanced (T3cd-T4) and not locally advanced (T1-T3ab). Surgical and histopathological findings served as reference standard. Results: Using MRI, T-stage, N-stage, and extramural venous invasion were correctly predicted for each observer in 90% and 93%, 72% and 69%, and 82% and 78% of cases, respectively. With CT the corresponding results were 79% and 76%, 72% and 72%, 78% and 67%. For MRI inter-observer agreements (Kappa statistics) were 0.79, 0.10, and 0.76. For CT the corresponding results were 0.64, 0.66, and 0.22. Conclusion: Patients with locally advanced colon cancer, defined as tumor stage T3cd-T4, can be identified by both high resolution MRI and CT, even when CT is performed with a metastasis staging protocol. MRI may have an advantage, due to its high soft tissue discrimination, to identify certain prognostic factors such as T-stage and extramural venous invasion.

  15. Heterogeneous pattern of retinal nerve fiber layer in multiple sclerosis. High resolution optical coherence tomography: potential and limitations.

    Science.gov (United States)

    Serbecic, Nermin; Aboul-Enein, Fahmy; Beutelspacher, Sven C; Graf, Martin; Kircher, Karl; Geitzenauer, Wolfgang; Brannath, Werner; Lang, Priska; Kristoferitsch, Wolfgang; Lassmann, Hans; Reitner, Andreas; Schmidt-Erfurth, Ursula

    2010-11-08

    Recently the reduction of the retinal nerve fibre layer (RNFL) was suggested to be associated with diffuse axonal damage in the whole CNS of multiple sclerosis (MS) patients. However, several points are still under discussion. (1) Is high resolution optical coherence tomography (OCT) required to detect the partly very subtle RNFL changes seen in MS patients? (2) Can a reduction of RNFL be detected in all MS patients, even in early disease courses and in all MS subtypes? (3) Does an optic neuritis (ON) or focal lesions along the visual pathways, which are both very common in MS, limit the predication of diffuse axonal degeneration in the whole CNS? The purpose of our study was to determine the baseline characteristics of clinical definite relapsing-remitting (RRMS) and secondary progressive (SPMS) MS patients with high resolution OCT technique. Forty-two RRMS and 17 SPMS patients with and without history of uni- or bilateral ON, and 59 age- and sex-matched healthy controls were analysed prospectively with the high resolution spectral-domain OCT device (SD-OCT) using the Spectralis 3.5mm circle scan protocol with locked reference images and eye tracking mode. Furthermore we performed tests for visual and contrast acuity and sensitivity (ETDRS, Sloan and Pelli-Robson-charts), for color vision (Lanthony D-15), the Humphrey visual field and visual evoked potential testing (VEP). All 4 groups (RRMS and SPMS with or without ON) showed significantly reduced RNFL globally, or at least in one of the peripapillary sectors compared to age-/sex-matched healthy controls. In patients with previous ON additional RNFL reduction was found. However, in many RRMS patients the RNFL was found within normal range. We found no correlation between RNFL reduction and disease duration (range 9-540 months). RNFL baseline characteristics of RRMS and SPMS are heterogeneous (range from normal to markedly reduced levels).

  16. Heterogeneous pattern of retinal nerve fiber layer in multiple sclerosis. High resolution optical coherence tomography: potential and limitations.

    Directory of Open Access Journals (Sweden)

    Nermin Serbecic

    Full Text Available BACKGROUND: Recently the reduction of the retinal nerve fibre layer (RNFL was suggested to be associated with diffuse axonal damage in the whole CNS of multiple sclerosis (MS patients. However, several points are still under discussion. (1 Is high resolution optical coherence tomography (OCT required to detect the partly very subtle RNFL changes seen in MS patients? (2 Can a reduction of RNFL be detected in all MS patients, even in early disease courses and in all MS subtypes? (3 Does an optic neuritis (ON or focal lesions along the visual pathways, which are both very common in MS, limit the predication of diffuse axonal degeneration in the whole CNS? The purpose of our study was to determine the baseline characteristics of clinical definite relapsing-remitting (RRMS and secondary progressive (SPMS MS patients with high resolution OCT technique. METHODOLOGY: Forty-two RRMS and 17 SPMS patients with and without history of uni- or bilateral ON, and 59 age- and sex-matched healthy controls were analysed prospectively with the high resolution spectral-domain OCT device (SD-OCT using the Spectralis 3.5mm circle scan protocol with locked reference images and eye tracking mode. Furthermore we performed tests for visual and contrast acuity and sensitivity (ETDRS, Sloan and Pelli-Robson-charts, for color vision (Lanthony D-15, the Humphrey visual field and visual evoked potential testing (VEP. PRINCIPAL FINDINGS: All 4 groups (RRMS and SPMS with or without ON showed significantly reduced RNFL globally, or at least in one of the peripapillary sectors compared to age-/sex-matched healthy controls. In patients with previous ON additional RNFL reduction was found. However, in many RRMS patients the RNFL was found within normal range. We found no correlation between RNFL reduction and disease duration (range 9-540 months. CONCLUSIONS: RNFL baseline characteristics of RRMS and SPMS are heterogeneous (range from normal to markedly reduced levels.

  17. Crazy-paving sign in high-resolution computed tomography in parainfluenza virus pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Matsuno, Osamu [Department of Respiratory Disease, NHO National Osaka Minami Medical Center, Kido higashi machi 2-1, Kawachinagano City, Osaka 586-8521 (Japan)], E-mail: matsuno@ommc-hp.jp; Hayama, Yoshitomo; Honda, Hidehiro; Yamane, Hiroyuki; Yamamoto, Suguru; Ueno, Kiyonobu [Department of Respiratory Disease, NHO National Osaka Minami Medical Center, Kido higashi machi 2-1, Kawachinagano City, Osaka 586-8521 (Japan); Saeki, Yukihiko [Department of Clinical Research, NHO National Osaka Minami Medical Center, Kido higashi machi 2-1, Kawachinagano city, Osaka 586-8521 (Japan)

    2010-05-15

    The crazy-paving sign is the appearance of a smooth linear pattern superimposed on an area of ground-glass opacity on thin-section computed tomography (CT). A 69-year-old woman was admitted to our hospital for treatment of pneumonia. Thoracic CT showed a crazy-paving sign in the right lung field on admission. She received ceftriaxone and clarithromycin, and the symptoms and infiltration shadow promptly disappeared. Serologic testing revealed a greater than 4-fold increase in the IgG titer for parainfluenza virus I. To our knowledge, there is no previous report of the crazy-paving sign in associated with viral pneumonia in a non-immunocompromised host or with parainfluenza pneumonia.

  18. Three dimensional characterization of laser ablation craters using high resolution X-ray computed tomography

    Science.gov (United States)

    Galmed, A. H.; du Plessis, A.; le Roux, S. G.; Hartnick, E.; Von Bergmann, H.; Maaza, M.

    2018-01-01

    Laboratory X-ray computed tomography is an emerging technology for the 3D characterization and dimensional analysis of many types of materials. In this work we demonstrate the usefulness of this characterization method for the full three dimensional analysis of laser ablation craters, in the context of a laser induced breakdown spectroscopy setup. Laser induced breakdown spectroscopy relies on laser ablation for sampling the material of interest. We demonstrate here qualitatively (in images) and quantitatively (in terms of crater cone angles, depths, diameters and volume) laser ablation crater analysis in 3D for metal (aluminum) and rock (false gold ore). We show the effect of a Gaussian beam profile on the resulting crater geometry, as well as the first visual evidence of undercutting in the rock sample, most likely due to ejection of relatively large grains. The method holds promise for optimization of laser ablation setups especially for laser induced breakdown spectroscopy.

  19. Pulmonary leukemic involvement: high-resolution computed tomography evaluation; Comprometimento pulmonar nas leucemias: avaliacao por tomografia computadorizada de alta resolucao

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Ana Paola de [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Programa de Pos-graduacao em Radiologia; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@bol.com.br; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Dept. de Radiologia

    2004-12-01

    Objective: To evaluate the role of high-resolution computed tomography (HRCT) in patients with leukemia and pulmonary symptoms, to establish the main patterns and to correlate them with the etiology. Materials and Methods: This is a retrospective study of the HRCT of 15 patients with leukemia and pulmonary symptoms. The examinations were performed using a spatial high-resolution protocol and were analyzed by two independent radiologists. Results: The main HRCT patterns found were ground-glass opacity (n=11), consolidation (n=9), airspace nodules (n=3), septal thickening (n=3), tree-in-bud pattern (n=3), and pleural effusion (n=3). Pulmonary infection was the most common finding seen in 12 patients: bacterial pneumonia (n=6), fungal infection (n = 4), pulmonary tuberculosis (n=1) and viral infection (n=1). Leukemic pleural infiltration (n=1), lymphoma (n=1) and pulmonary hemorrhage (n=1) were detected in the other three patients. Conclusion: HRCT is an important tool that may suggest the cause of lung involvement, its extension and in some cases to guide invasive procedures in patients with leukemia. (author)

  20. Bone Structure and Estimated Bone Strength in Obese Patients Evaluated by High-Resolution Peripheral Quantitative Computed Tomography

    DEFF Research Database (Denmark)

    Andersen, Stine; Frederiksen, Katrine Diemer; Hansen, Stinus

    2014-01-01

    females, age 25-56 years and BMI 33.2-57.6 kg/m(2)) matched with healthy controls (age 25-54 years and BMI 19.5-24.8 kg/m(2)) in regard to gender, menopausal status, age (±6 years) and height (±6 cm) using high resolution peripheral quantitative computed tomography and dual energy X-ray absorptiometry....... In radius, total bone area and trabecular area were significantly higher in obese patients (both p radius. Trabecular integrity was strengthened in obese...... patients compared with controls in radius and tibia with higher trabecular number (p = 0.002 and p radius in obese patients. FL was significantly...

  1. Ultra-high resolution polarization-sensitive optical coherence tomography for imaging of the retinal nerve fiber layer

    Science.gov (United States)

    Cense, Barry; Reddikumar, Maddipatla; Cervantes, Joel

    2017-04-01

    A spectrometer design with a multiple line line-scan camera and beam displacer is presented for ultra-high resolution optical coherence tomography measurements of the human retina at 840 nm. The beam displacer offsets the two orthogonal polarization states on the same line-scan camera, which reduces k-space mapping complexity, as data in both polarization channels can be mapped with the same procedure. Its coherence length is 2.8 μm in tissue (n = 1.38). Birefringence values of 1°/μm and higher were found in a circle with a radius of 2.5° eccentricity centered on the fovea, and in the raphe, pointing at a higher packing density of microtubules and a lower concentration of glia. Birefringence measurements may be more helpful in the modeling of individual structure-function maps than thickness measurements, as they are not affected by glial content.

  2. Assessment of pulmonary changes in the course of systemic lupus erythematosus – application of high resolution computed tomography

    Directory of Open Access Journals (Sweden)

    Sławomir Jeka

    2014-11-01

    Full Text Available Systemic lupus erythematosus (SLE is an autoimmune disease that leads to a chronic inflammatory process in tissues and organs. The ailments of the respiratory system are dominated by dry or exudative pleurisy. Interstitial changes can occur, and their effects vary depending on their severity. In extreme cases, they may lead to death. The paper presents a description of three SLE patients with different severity of organ changes treated in the Department of Rheumatology. During the process of diagnosis and treatment, among others chest X-ray and high resolution computed tomography (HRCT of the lungs were performed. Based on the chest X-ray results, no interstitial lung changes were detected, whereas based on the HRCT every patient was diagnosed with an interstitial lung process. In the assessment of pulmonary changes in the course of SLE, HRCT allows the diagnosis of organ damage in an early stage and the introduction of appropriate treatment.

  3. Computerized tomography of Castleman's disease simulating a false renal artery aneurysm: a case report.

    Science.gov (United States)

    Friedman, L; Dubowitz, B; Papert, B; Porteous, P

    1987-07-01

    We report a case of retroperitoneal Castleman's disease of the hyaline vascular type simulating a false renal artery aneurysm. Excretory urography with computerized tomography and angiographic findings are presented. All 3 investigations demonstrated a homogeneously enhancing hypervascular retroperitoneal mass.

  4. In vivo imaging of raptor retina with ultra high resolution spectral domain optical coherence tomography

    Science.gov (United States)

    Ruggeri, Marco; Major, James C., Jr.; McKeown, Craig; Wehbe, Hassan; Jiao, Shuliang; Puliafito, Carmen A.

    2008-02-01

    Among birds, raptors are well known for their exceptional eyesight, which is partly due to the unique structure of their retina. Because the raptor retina is the most advanced of any animal species, in vivo examination of its structure would be remarkable. Furthermore, a noticeable percentage of traumatic ocular injuries are identified in birds of prey presented to rehabilitation facilities. Injuries affecting the posterior segment have been considered as a major impact on raptor vision. Hence, in vivo examination of the structure of the posterior segment of the raptors would be helpful for the diagnosis of traumatized birds. The purpose of this study is to demonstrate the application of ultrahigh-resolution Spectral Domain Optical Coherence Tomography (SD-OCT) for non contact in vivo imaging of the retina of birds of prey, which to the best of our knowledge has never been attempted. For the first time we present high quality OCT images of the retina of two species of bird of prey, one diurnal hawk and one nocturnal owl.

  5. An alternative approach to computerized tomography (CT) in forensic pathology.

    Science.gov (United States)

    Thomsen, Asser H; Jurik, Anne Grethe; Uhrenholt, Lars; Vesterby, Annie

    2009-01-10

    Computerized Tomography (CT) is used by some forensic pathology departments as a supplement to the forensic autopsy. Departments with a limited number of autopsies may find it relatively expensive to acquire and operate a CT-scanner. Furthermore, it requires a great deal of training and experience to interpret the radiological data. We are currently evaluating CT in order to decide whether the benefits match the efforts. In selected death-investigations the Department of Radiology at Aarhus University Hospital performs CT of the body on behalf of the Institute of Forensic Medicine at Aarhus University and a skilled radiologist interprets the data. We present our radiological findings in the 20 cases where we have used CT and compare them to the autopsy findings. The cases include fatalities from beatings, stabbings, gunshots, fires and traffic accidents. CT is an excellent tool for documenting and illustrating certain lesions, such as gunshot wounds and bone fractures, where we can obtain information that possibly would have been missed at the autopsy. We believe, however, that further research is required before we can recommend CT as a part of a standard forensic autopsy. The cooperation between forensic and radiological departments is a good approach for smaller forensic departments that insures a skilled interpretation without having to divert a lot of resources to equipment and training.

  6. Percutaneous nephrolithotomy in pediatric patients: is computerized tomography a must?

    Science.gov (United States)

    Gedik, Abdullah; Tutus, Ali; Kayan, Devrim; Yılmaz, Yakup; Bircan, Kamuran

    2011-02-01

    The aim of this study was to retrospectively evaluate the results of pediatric percutaneous nephrolithotomy (PNL) cases, and discuss the results and necessity of non-contrast computerized tomography (CT) in these cases. In all, 48 pediatric patients who underwent PNL were retrospectively evaluated. Before PNL, either intravenous urography or CT was performed. In all patients, we evaluated the PNL time, scopy time with stone burden, and complications. During the PNL procedure, we switched to open surgery in two cases: in one because of renal pelvis perforation and in the other because of transcolonic access. In one patient who was scheduled to undergo PNL, we performed open surgery, primarily because we detected a retrorenal colon with CT. The stone burden in 45 patients who underwent PNL was 445 ± 225 mm(2), the PNL time was 51 ± 23 min, and the scopy time was 6.1 ± 2.7 min. We removed nephrostomy tubes 1-4 days after the procedure. In two patients, 24 h after removal of nephrostomy tubes, we inserted double J stents because of prolonged urine extravasation from the tract. In all, 34 of the 45 patients were stone-free, 5 patients had clinically insignificant stone fragments, and 6 patients had residual stones. PNL is a safe and effective method in the treatment of pediatric patients with kidney stones. Clinical experience is the most important factor in obtaining stone-free results. CT should be performed in all pediatric patients in order to prevent colon perforation.

  7. Trauma surgeon utilization of computerized tomography scanning: Room for improvement?

    Science.gov (United States)

    Ong, Adrian W; Moyer, Jeffery; Wordofa, Fikir D; Sigal, Adam; Sandel, Kristen; Fernandez, Forrest B

    2017-03-01

    We aimed to evaluate computerized tomography (CT) utilization and yield rates for trauma team activations (TTA). A retrospective review of all TTAs was conducted over nine months. TTAs consisted of two levels--trauma alert (TAL) and trauma response (TR). Yields of CT for significant findings (SF) for four CT types (brain, cervical, chest, abdomen/pelvis) were recorded. 647 patients were included. There was no difference in the utilization rates of CTs except for brain CTs (TAL, 98% vs TR, 94%, p = 0.008). There was no difference in the yield rates except for cervical spine CTs (TAL, 8% vs TR, 4%, p = 0.03). Over 80% received a pan scan regardless of TTA level; 63% who had any CT had no SF. The median ratio of scans with SF to the total number of scans per patient was 0. Regardless of activation level, CT seems to be over utilized. More selective use of CT should be evaluated. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Characterizing analogue caldera collapse with computerized X-ray micro-tomography

    Science.gov (United States)

    Poppe, Sam; Holohan, Eoghan; Boone, Matthieu; Pauwels, Elin; Cnudde, Veerle; Kervyn, Matthieu

    2013-04-01

    Analogue models in the past mainly explored caldera collapse structures by documenting 2D model cross-sections. Kinematic aspects and 3D structures of caldera collapse are less well understood, although they are essential to interpret recent field and monitoring data. We applied high resolution radiography and computerized X-ray micro-tomography (µCT) to image the deformation during analogue fluid withdrawal in small-scale caldera collapse models. The models test and highlight the possibilities and limitations of µCT-scanning to qualitatively image and quantitatively analyse deformation of analogue volcano-tectonic experiments. High resolution interval radiography sequences document '2.5D' surface and internal model geometry, and subsidence kinematics of a collapsing caldera block into an emptying fluid body in an unprecedented way. During the whole drainage process, all subsidence was bound by caldera ring faults. Subsidence was associated with dilatation of the analogue granular material within the collapsing column. The temporal subsidence rate pattern within the subsiding volume comprised three phases: 1) Upward ring fault propagation, 2) Rapid subsidence with the highest subsidence rates within the uppermost subsiding volume, 3) Relatively slower subsidence rates over the whole column with intermittent subsidence rate acceleration. Such acceleration did almost never affect the whole column. By using radiography sequences it is possible in a non-destructive manner to obtain a continuous observation of fault propagation, down sag mechanisms and the subsequent development of collapse structures. Multi-angle µCT scans of the collapse result allow for a full virtual 3D reconstruction of the model. This leads to an unprecedented 3D view on fault geometries. The developed method is a step towards the quantitative documentation of volcano-tectonic models that would render data interpretations immediately comparable to monitoring data available from recent

  9. Designing A New CAD System for Pulmonary Nodule Detection in High Resolution Computed Tomography (HRCT Images

    Directory of Open Access Journals (Sweden)

    M Bakhshayesh Karam

    2012-07-01

    Full Text Available Background: Lung diseases and lung cancer are among the most dangerous diseases with high mortality in both men and women. Lung nodules are abnormal pulmonary masses and are among major lung symptoms. A Computer Aided Diagnosis (CAD system may play an important role in accurate and early detection of lung nodules. This article presents a new CAD system for lung nodule detection from chest computed tomography (CT images.Methods: Twenty-five adult patients with lung nodules in their CT scan images presented to the National Research Institute of Tuberculosis and Lung Disease, Masih Daneshvari Hospital, Tehran, Iran in 2011-2012 were enrolled in the study. The patients were randomly assigned into two experimental (9 female, 6 male, mean age 43±5.63 yrs and control (6 female, 4 male, mean age 39±4.91 yrs groups. A fully-automatic method was developed for detecting lung nodules by employing medical image processing and analysis and statistical pattern recognition algorithms.esults: Using segmentation methods, the lung parenchyma was extracted from 2-D CT images. Then, candidate regions were labeled in pseudo-color images. In the next step, some features of lung nodules were extracted. Finally, an artificial feed forward neural network was used for classification of nodules.Conclusion: Considering the complexity and different shapes of lung nodules and large number of CT images to evaluate, finding lung nodules are difficult and time consuming for physicians and include human error. Experimental results showed the accuracy of the proposed method to be appropriate (P<0.05 for lung nodule detection.

  10. Regional airway obstruction in cystic fibrosis determined by electrical impedance tomography in comparison with high resolution CT.

    Science.gov (United States)

    Zhao, Zhanqi; Müller-Lisse, Ullrich; Frerichs, Inéz; Fischer, Rainald; Möller, Knut

    2013-11-01

    Electrical impedance tomography (EIT) is able to deliver regional information to assess the airway obstruction in patients with cystic fibrosis (CF). In the present study, regional obstruction in CF patients measured by EIT was compared with high resolution computed tomography (HRCT). Five CF patients were routinely scheduled for HRCT examination. EIT measurements were performed on these patients ±2 months during a standard pulmonary function test. The weighted Brody score derived from HRCT, which considers bronchiectasis, mucus plugging, peribronchial thickening, parenchymal opacity and hyperinflation, was calculated from the CT scans acquired at the location of EIT electrodes ±5 cm. Ratios of maximum expiratory flows at 25% and 75% of vital capacity (MEF25/MEF75) with respect to relative impedance change were calculated for regional areas in EIT images. Regional airway obstruction identified in the MEF25/MEF75 maps was similar to that found in CT. Median values of MEF25/MEF75 and weighted Brody score were highly correlated (r(2) = 0.83, P < 0.05). We found that regional obstruction measured by EIT is reliable and may be used as an additional clinical examination tool for CF patients.

  11. The Sensitivity and Specificity of a new Scoring System Using High Resolution Computed Tomography to Diagnose Lung Cancer

    Directory of Open Access Journals (Sweden)

    Arman A. Abdullah

    2009-09-01

    Full Text Available Aim To find a non-invasive diagnostic method for lung cancer with the results almost as accurate as histopathological examinations using HRCT scoring system.Method This study was conducted from December 2006 until March 2008. A total of 55 persons, comprised of 40 male and 15 female patients suspected of having lung cancer, underwent high resolution computed tomography with and without contrast as well as CT-guided transthoracic needle aspiration to obtain cytology specimens.Results Histopathological examinations revealed the existence of lung cancer in 43 patients (78% and benign lesions in 12 patients (22%. A scoring system was then made based on the similarities of findings from CT and histopathologic examinations. In the the age group of 49 years and above, tumor volume of more than 68 cm3, HU of more than 21, spicula positive, angiogram positive and lymph node positive had a value of respectively 20, 19, 10, 24, 18, and 17 (total score 108.Conclusion This new method to diagnose lung cancer is constantly as accurate as histological findings with a sensitivity of 97.7% and a specificity of 83,3% and a cut-off score of 35. According to this system, a score of less than 35 indicates that the lesions were benign while a score higher than 35 is suggestive malignant. (Med J Indones2009;18:179-86Key word: High resolution CT; Lung cancer; Scoring

  12. Computerized tomography with total variation and with shearlets

    Science.gov (United States)

    Garduño, Edgar; Herman, Gabor T.

    2017-04-01

    To reduce the x-ray dose in computerized tomography (CT), many constrained optimization approaches have been proposed aiming at minimizing a regularizing function that measures a lack of consistency with some prior knowledge about the object that is being imaged, subject to a (predetermined) level of consistency with the detected attenuation of x-rays. One commonly investigated regularizing function is total variation (TV), while other publications advocate the use of some type of multiscale geometric transform in the definition of the regularizing function, a particular recent choice for this is the shearlet transform. Proponents of the shearlet transform in the regularizing function claim that the reconstructions so obtained are better than those produced using TV for texture preservation (but may be worse for noise reduction). In this paper we report results related to this claim. In our reported experiments using simulated CT data collection of the head, reconstructions whose shearlet transform has a small ℓ 1-norm are not more efficacious than reconstructions that have a small TV value. Our experiments for making such comparisons use the recently-developed superiorization methodology for both regularizing functions. Superiorization is an automated procedure for turning an iterative algorithm for producing images that satisfy a primary criterion (such as consistency with the observed measurements) into its superiorized version that will produce results that, according to the primary criterion are as good as those produced by the original algorithm, but in addition are superior to them according to a secondary (regularizing) criterion. The method presented for superiorization involving the ℓ 1-norm of the shearlet transform is novel and is quite general: It can be used for any regularizing function that is defined as the ℓ 1-norm of a transform specified by the application of a matrix. Because in the previous literature the split Bregman algorithm is used

  13. Topographic thickness of Bowman's layer determined by ultra-high resolution spectral domain-optical coherence tomography.

    Science.gov (United States)

    Tao, Aizhu; Wang, Jianhua; Chen, Qi; Shen, Meixiao; Lu, Fan; Dubovy, Sander R; Shousha, Mohamed Abou

    2011-06-01

    To characterize the thickness profile of the corneal epithelium and the Bowman's layer across the horizontal meridian. Forty-four eyes of 22 healthy subjects were investigated in this study. Ultra-high resolution anterior segment spectral domain-optical coherence tomography (SD-OCT) was used to assess the topographic thickness of the epithelium and the Bowman's layer across the cornea. Thicknesses at five locations, including the center, midperiphery, and periphery close to the limbus, on both the nasal and the temporal sides along the horizontal meridian, were analyzed. Mean epithelial thickness at the central cornea was 52.5 ± 2.4 μm. It increased gradually from the center to the periphery (P 0.05). However, thicknesses at the nasal and temporal periphery, 20.0 ± 1.9 μm and 19.8 ± 2.2 μm, respectively, were significantly greater than the central and midperipheral thicknesses (P < 0.001). Nasal and temporal thicknesses were similar on either side of the center. The epithelium and the Bowman's layer were not evenly distributed across the horizontal meridian of the cornea. SD-OCT provided useful information about topographic thickness of the different corneal layers in vivo.

  14. Topographic Thickness of Bowman's Layer Determined by Ultra-High Resolution Spectral Domain–Optical Coherence Tomography

    Science.gov (United States)

    Tao, Aizhu; Chen, Qi; Shen, Meixiao; Lu, Fan; Dubovy, Sander R.; Shousha, Mohamed Abou

    2011-01-01

    Purpose. To characterize the thickness profile of the corneal epithelium and the Bowman's layer across the horizontal meridian. Methods. Forty-four eyes of 22 healthy subjects were investigated in this study. Ultra-high resolution anterior segment spectral domain–optical coherence tomography (SD-OCT) was used to assess the topographic thickness of the epithelium and the Bowman's layer across the cornea. Thicknesses at five locations, including the center, midperiphery, and periphery close to the limbus, on both the nasal and the temporal sides along the horizontal meridian, were analyzed. Results. Mean epithelial thickness at the central cornea was 52.5 ± 2.4 μm. It increased gradually from the center to the periphery (P 0.05). However, thicknesses at the nasal and temporal periphery, 20.0 ± 1.9 μm and 19.8 ± 2.2 μm, respectively, were significantly greater than the central and midperipheral thicknesses (P < 0.001). Nasal and temporal thicknesses were similar on either side of the center. Conclusions. The epithelium and the Bowman's layer were not evenly distributed across the horizontal meridian of the cornea. SD-OCT provided useful information about topographic thickness of the different corneal layers in vivo. PMID:21460260

  15. Functional optical coherence tomography for high-resolution mapping of cilia beat frequency in the mouse oviduct in vivo

    Science.gov (United States)

    Wang, Shang; Burton, Jason C.; Behringer, Richard R.; Larina, Irina V.

    2016-02-01

    Since mouse is a superior model for genetic analysis of human disorders, reproductive studies in mice have significant implications on further understanding of fertility and infertility in humans. Fertilized oocytes are transported through the reproductive tract by motile cilia lining the lumen of the oviduct as well as by oviduct contractions. While the role of cilia is well recognized, ciliary dynamics in the oviduct is not well understood, largely owing to the lack of live imaging approaches. Here, we report in vivo micro-scale mapping of cilia and cilia beat frequency (CBF) in the mouse oviduct using optical coherence tomography (OCT). This functional imaging method is based on spectral analysis of the OCT speckle variations produced by the beat of cilia in the oviduct, which does not require exogenous contrast agents. Animal procedures similar to the ones used for production of transgenic mice are utilized to expose the reproductive organs for imaging in anesthetized females. In this paper, we first present in vivo structural imaging of the mouse oviduct capturing the oocyte and the preimplantation embryo and then show the result of depth-resolved high-resolution CBF mapping in the ampulla of the live mouse. These data indicate that this structural and functional OCT imaging approach can be a useful tool for a variety of live investigations of mammalian reproduction and infertility.

  16. High-resolution Computed Tomography Findings of H1N1 Influenza-Associated Pneumonia in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Chan; Choi, Song; Kim, Jin Woong; Lim, Hyo Soon [Dept. of Radiology, Chonnam National University Hospital, Chonnam National University School of Medicine, Kwangju (Korea, Republic of); Seon, Hyung Joo; Shin, Sang Soo [Dept. of Radiology, Chonnam National University Hospital, Chonnam National University School of Medicine, Kwangju (Korea, Republic of); Kim, Yun Hyeon; Park, Kyung Hwa [Dept. of Internal Medicine, Chonnam National University Hospital, Chonnam National University School of Medicine, Kwangju (Korea, Republic of)

    2011-04-15

    To evaluate and compare the high-resolution computed tomography (HRCT) findings of patients with H1N1 influenza-associated pneumonia compared usual community acquired pneumonia (CAP), to determine whether there were any useful common HRCT findings predicting their prognosis. HRCT findings of 31 patients (M:F = 16:15, mean age 42 yrs) with Influenza A (H1N1) infection were retrospectively reviewed for abnormal HRCT findings and compared to HRCT findings of CAP in matched patients. Patients were matched according to age and sex, from 2009 to January 2010. The predominant HRCT findings of pneumonia consisted of areas of consolidation and/or groundglass opacity (GGO) which showed no statistically significant differences when comparing the two groups. However, the abnormalities of H1N1-related pneumonia showed higher bilaterality and multilobar or multisegmental involvement compared with CAP (p < 0.05). Internal low attenuation or air-densities in pulmonary infiltration /or lymphadenopathy was observed only in patients with CAP (p < 0.05). HRCT findings in 8 patients with poor clinical outcome had bilaterality (p=0.015), multilobar, and multisegmental involvement. The predominant HRCT findings of H1N1-related pneumonia were areas of consolidation and/or GGO. In addition, H1N1-related pneumonia showed higher bilaterality or multilobar/multisegmental involvement compared with CAP. The patients who presented bilaterality had a worse clinical outcome.

  17. Accuracy of high-resolution computed tomography in revealing fallopian canal fracture of patients with traumatic facial paralysis.

    Science.gov (United States)

    Yan, Chun; He, Benhong; Wang, Xingzheng; Qin, Zhong; Li, Yefeng; Peng, Yongli

    2015-10-01

    To investigate accuracy of high-resolution computed tomography (HRCT) of temporal bone in revealing fallopian canal fracture among the patients with traumatic facial paralysis. HRCT of temporal bone with cross-sectional scanning and multi-planar reformation (MPR) was performed on 31 patients with traumatic facial paralysis, and fracture sites of fallopian canal revealed by HRCT were retrospectively analyzed and compared with surgical findings. HRCT of temporal bone showed fracture of fallopian canal at geniculate ganglion in 25 cases, at tympanic segment in 15 cases, at labyrinthine segment in 5 cases, at pyramid segment in 2 cases, and at mastoid segment in one case, while surgical findings revealed that fracture involved geniculate ganglion in 27 cases, labyrinthine segment in 5, tympanic segment in 19, pyramid segment in 12, and mastoid segment in 9; the sensitivity of HRCT of temporal bone to detect fracture at such sites was 88.9%, 100%, 52.6%, 16.7% and 11.1%, respectively, and the specificity was 96.0%, 100%, 66.7%, 100% and 100%, respectively. HRCT of temporal bone was able to accurately reveal fracture of fallopian canal at geniculate ganglion and labyrinthine segment in the vast majority cases, but severely underestimated fracture at pyramid segment and mastoid segment of fallopian canal. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. High-resolution computed tomography bronchial lumen to pulmonary artery diameter ratio in anesthetized ventilated cats with normal lungs.

    Science.gov (United States)

    Reid, Lauren E; Dillon, A Ray; Hathcock, John T; Brown, Lawrence A; Tillson, Michael; Wooldridge, Anne A

    2012-01-01

    High-resolution computed tomography (CT) is the preferred noninvasive tool for diagnosing bronchiectasis in people. A criterion for evaluating dilation of the bronchus is the bronchial lumen to pulmonary artery diameter (bronchoarterial ratio [BA ratio]). A ratio of > 1.0 in humans or > 2.0 in dogs has been suggested as a threshold for identifying bronchiectasis. The purpose of this study was to establish the BA ratio in normal cats. Fourteen specific pathogen-free cats were selected for analysis of thoracic CT images. The BA ratios of the lobar bronchi of the left cranial (cranial and caudal parts), right cranial, right middle, left caudal, and right caudal lung lobes were measured. The mean of the mean BA ratio of all lung lobes was 0.71 +/- 0.05. Individual BA ratios ranged from 0.5 to 1.11. Comparing individual lobes for each cat, there was no significant difference (P = 0.145) in mean BA ratio between lung lobes. A mean BA ratio for these normal cats was 0.71 +/- 0.1, which suggests an upper cut-off normal value > 0.91 (mean +/- 2 standard deviations) between normal and abnormal cats.

  19. Cost effectiveness of high resolution computed tomography with interferon-gamma release assay for tuberculosis contact investigation

    Energy Technology Data Exchange (ETDEWEB)

    Kowada, Akiko, E-mail: kowadaa@gmail.com [Kojiya Haneda Healthcare Service, Ota City Public Health Office, Tokyo (Japan)

    2013-08-15

    Background: Tuberculosis contact investigation is one of the important public health strategies to control tuberculosis worldwide. Recently, high resolution computed tomography (HRCT) has been reported as a more accurate radiological method with higher sensitivity and specificity than chest X-ray (CXR) to detect active tuberculosis. In this study, we assessed the cost effectiveness of HRCT compared to CXR in combination with QuantiFERON{sup ®}-TB Gold In-Tube (QFT) or the tuberculin skin test (TST) for tuberculosis contact investigation. Methods: We constructed Markov models using a societal perspective on the lifetime horizon. The target population was a hypothetical cohort of immunocompetent 20-year-old contacts with smear-positive tuberculosis patients in developed countries. Six strategies; QFT followed by CXR, QFT followed by HRCT, TST followed by CXR, TST followed by HRCT, CXR alone and HRCT alone were modeled. All costs and clinical benefits were discounted at a fixed annual rate of 3%. Results: In the base-case analysis, QFT followed by HRCT strategy yielded the greatest benefit at the lowest cost ($US 6308.65; 27.56045 quality-adjusted life-years [QALYs])[year 2012 values]. Cost-effectiveness was sensitive to BCG vaccination rate. Conclusions: The QFT followed by HRCT strategy yielded the greatest benefits at the lowest cost. HRCT chest imaging, instead of CXR, is recommended as a cost effective addition to the evaluation and management of tuberculosis contacts in public health policy.

  20. Changes in structural lung disease in cystic fibrosis children over 4 years as evaluated by high-resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Carpio, Carlos; Alvarez-Sala, Rodolfo; Prados, Concepcion [University Hospital La Paz, La Paz Hospital Research Institute, Department of Respiratory Medicine, Madrid (Spain); Albi, Gustavo [Nino de Jesus Children' s Hospital, Department of Radiology, Madrid (Spain); Rayon-Aledo, Jose Carlos; Caballero, Paloma [University Hospital La Princesa, Department of Radiology, Madrid (Spain); Giron, Rosa [University Hospital La Princesa, Department of Respiratory Medicine, Madrid (Spain)

    2015-12-15

    To compare the worsening of structural lung disease on high-resolution computed tomography (HRCT) with changes in spirometry results in cystic fibrosis (CF) patients, and analyse factors associated with the worsening of structural lung disease over time. A total of 31 CF subjects (mean age 11.03 ± 3.67 years old) were prospectively evaluated by two HRCT and spirometry tests performed 4 years apart. HRCT abnormalities were scored using the Bhalla scoring system. Comparisons between changes on HRCT and spirometry were made for all patients, and also for groups categorized by age, sex, genotypic alterations and lung obstruction. The mean HRCT Bhalla scoring, forced expiratory volume in 1 s (FEV{sub 1} %pred.) and forced vital capacity (FVC %pred.) were 7.92 ± 3.59, 87.76 ± 20.52 and 96.54 ± 15.12, respectively. There was a significant deterioration in the Bhalla score (p < 0.01) and in certain categories: severity of bronchiectasis, peribronchial thickening, mucous plugging and bronchial divisions. Females had a more pronounced worsening of the Bhalla score than males (p = 0.048). No change over time was found in FEV{sub 1} and FVC. Only sex was associated with a deterioration in HRCT. HRCT Bhalla scoring changes statistically significantly over 4 years, but spirometry results do not. Worsening on HRCT is more evident in females. (orig.)

  1. Clinical Impact of Emphysema Evaluated by High-Resolution Computed Tomography on Idiopathic Pulmonary Fibrosis Diagnosed by Surgical Lung Biopsy.

    Science.gov (United States)

    Kohashi, Yasuo; Arai, Toru; Sugimoto, Chikatoshi; Tachibana, Kazunobu; Akira, Masanori; Kitaichi, Masanori; Hayashi, Seiji; Inoue, Yoshikazu

    2016-01-01

    The prognosis of combined cases of pulmonary fibrosis and emphysema is unresolved partially because radiological differentiation between usual interstitial pneumonia and nonspecific interstitial pneumonia is difficult in coexisting emphysema cases. The purpose of this study was to clarify the clinical impact of emphysema on the survival of patients with idiopathic pulmonary fibrosis (IPF). One hundred and seven patients with interstitial lung diseases were diagnosed by surgical lung biopsies between 2006 and 2012, and 47 patients were diagnosed with IPF through multidisciplinary discussion. Emphysema on high-resolution computed tomography scans was evaluated semiquantitatively by visual scoring. Eight out of the 47 IPF patients showed a higher emphysema score (>3) and were diagnosed to have IPF-emphysema. The median survival time of patients with IPF-emphysema (1,734 days) from the initial diagnosis was significantly shorter than that of patients with IPF alone (2,229 days) by Kaplan-Meier analysis (p = 0.007, log-rank test). Univariate Cox proportional hazard regression analyses revealed that a higher total emphysema score (>3.0) was a significantly poor prognostic factor in addition to Krebs von den Lungen-6, surfactant protein-D, arterial oxygen tension, percent forced vital capacity, and percent diffusing capacity of carbon monoxide (%DLCO). Multivariate Cox proportional hazard regression analyses with the stepwise method showed that higher total emphysema score (>3) and %DLCO were significantly poor prognostic factors. The prognosis of IPF-emphysema was significantly worse than that of IPF alone. © 2016 S. Karger AG, Basel.

  2. High-resolution breast tomography at high energy: a feasibility study of phase contrast imaging on a whole breast

    Science.gov (United States)

    Sztrókay, A.; Diemoz, P. C.; Schlossbauer, T.; Brun, E.; Bamberg, F.; Mayr, D.; Reiser, M. F.; Bravin, A.; Coan, P.

    2012-05-01

    Previous studies on phase contrast imaging (PCI) mammography have demonstrated an enhancement of breast morphology and cancerous tissue visualization compared to conventional imaging. We show here the first results of the PCI analyser-based imaging (ABI) in computed tomography (CT) mode on whole and large (>12 cm) tumour-bearing breast tissues. We demonstrate in this work the capability of the technique of working at high x-ray energies and producing high-contrast images of large and complex specimens. One entire breast of an 80-year-old woman with invasive ductal cancer was imaged using ABI-CT with monochromatic 70 keV x-rays and an area detector of 92×92 µm2 pixel size. Sagittal slices were reconstructed from the acquired data, and compared to corresponding histological sections. Comparison with conventional absorption-based CT was also performed. Five blinded radiologists quantitatively evaluated the visual aspects of the ABI-CT images with respect to sharpness, soft tissue contrast, tissue boundaries and the discrimination of different structures/tissues. ABI-CT excellently depicted the entire 3D architecture of the breast volume by providing high-resolution and high-contrast images of the normal and cancerous breast tissues. These results are an important step in the evolution of PCI-CT towards its clinical implementation.

  3. High-resolution spectral domain optical coherence tomography technology for the visualization of contact lens to cornea relationships.

    Science.gov (United States)

    Gonzalez-Meijome, Jose M; Cerviño, Alejandro; Carracedo, Gonzalo; Queiros, Antonio; Garcia-Lázaro, Santiago; Ferrer-Blasco, Teresa

    2010-12-01

    To study the utility of high-resolution spectral domain optical coherence tomography (HR SOCT) in imaging the contact lens (CL) to cornea relationships with advanced CL designs for ecstatic corneas and corneal refractive therapy. Copernicus HR SOCT (Optopol Technology SA, Zawiercie, Poland) was used to evaluate different lens materials and designs in situ and for the preliminary assessment of the materials and corneal response to hypoxic situations. SOCT is capable of highlighting very subtle and interesting features of the CL-cornea relationships in a wide range of applications such as in rigid gas-permeable corneal and semiscleral lenses, in corneal refractive therapy and application of CLs in ocular pathology, and in the evaluation of the physiological response of the cornea. HR SOCT is a powerful tool capable of providing sharp images of the anterior ocular surface highlighting the relationship between lens and cornea with great detail. This methodology has several applications to enhance fitting modeling with modern designs for advanced CL treatments.

  4. Pulmonary malaria: high-resolution computed tomography findings - a case report; Malaria pulmonar: aspectos na tomografia computadorizada de alta resolucao - relato de caso

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Rosana; Souza, Daniel Andrade Tinoco de [Universidade Federal, Rio de Janeiro, RJ (Brazil). Hospital Universitario Clementino Fraga Filho. Servico de Radiodiagnostico; Hospital Copa D' Or, Rio de Janeiro, RJ (Brazil); Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@bol.com.br

    2004-04-01

    We report the case of a 38-year-old man with pulmonary malaria. High-resolution computed tomography showed thickening of the peribronchovascular interstitium and interlobular septa, areas of consolidation and ground glass attenuation and bilateral pleural effusion suggesting pulmonary edema. The patient recovered well after receiving specific treatment and was discharged after 11 days of hospitalization. (author)

  5. Computerized tomography-based anatomic description of the porcine liver.

    Science.gov (United States)

    Bekheit, Mohamed; Bucur, Petru O; Wartenberg, Mylene; Vibert, Eric

    2017-04-01

    The knowledge of the anatomic features is imperative for successful modeling of the different surgical situations. This study aims to describe the anatomic features of the porcine using computerized tomography (CT) scan. Thirty large, white, female pigs were included in this study. The CT image acquisition was performed in four-phase contrast study. Subsequently, analysis of the images was performed using syngo.via software (Siemens) to subtract mainly the hepatic artery and its branches. Analysis of the portal and hepatic veins division pattern was performed using the Myrian XP-Liver 1.14.1 software (Intrasense). The mean total liver volume was 915 ± 159 mL. The largest sector in the liver was the right medial one representing around 28 ± 5.7% of the total liver volume. Next in order is the right lateral sector constituting around 24 ± 5%. Its volume is very close to the volume of the left medial sector, which represents around 22 ± 4.7% of the total liver volume. The caudate lobe represents around 8 ± 2% of the total liver volume.The portal vein did not show distinct right and left divisions rather than consecutive branches that come off the main trunk. The hepatic artery frequently trifurcates into left trunk that gives off the right gastric artery and the artery to the left lateral sector, the middle hepatic artery that supplies both the right and the left medial sectors and the right hepatic artery trunk that divides to give anterior branch to the right lateral lobe, branch to the right medial lobe, and at least a branch to the caudate lobe. Frequently, there is a posterior branch that crosses behind the portal vein to the right lateral lobe. The suprahepatic veins join the inferior vena cava in three distinct openings. There are communications between the suprahepatic veins that drain the adjacent sectors. The vein from the right lateral and the right medial sectors drains into a common trunk. The vein from the left lateral and from the left

  6. Use of ultra-high-resolution optical coherence tomography to detect in vivo characteristics of Descemet's membrane in Fuchs' dystrophy.

    Science.gov (United States)

    Shousha, Mohamed Abou; Perez, Victor L; Wang, Jianhua; Ide, Takeshi; Jiao, Shuliang; Chen, Qi; Chang, Victoria; Buchser, Nancy; Dubovy, Sander R; Feuer, William; Yoo, Sonia H

    2010-06-01

    To demonstrate the capability of ultra-high-resolution (UHR) anterior segment optical coherence tomography (OCT) to image Descemet's membrane (DM) and measure its thickness in vivo. (2) To evaluate the use of DM characteristics and thickness in the diagnosis of Fuchs' dystrophy. Case-control study. Twenty eyes of 12 Fuchs' dystrophy patients, 20 eyes of 13 young normal, and 20 eyes of 15 elderly normal subjects. Subjects were imaged using novel, custom-built UHR-OCT. Images were used to describe the characteristics of DM. Custom-made software was used to measure DM thickness and central corneal thickness (CCT). Specimens of DM obtained from Fuchs' dystrophy patients who underwent endothelial keratoplasty (EK) were histopathologically examined. Regression analyses were used to assess the correlation of DM thickness measured by UHR-OCT in vivo and by light microscopy and to determine the intergroup correlations between age, CCT, and DM thickness. We assessed DM characteristics and thickness, CCT, and age. Using UHR-OCT, the DM seemed in normal young subjects as a single, opaque, smooth line and in normal elderly subjects as a band of 2 smooth opaque lines with a translucent space in between. In Fuchs' dystrophy, DM appeared as a thickened band of 2 opaque lines; the anterior line was smooth whereas the posterior line had a wavy and irregular appearance with areas of localized thickenings. The DM thickness measured in vivo by UHR-OCT correlated significantly with that measured by light microscopy in 5 Fuchs' dystrophy eyes that underwent EK. The average central thicknesses of DM in normal young, in normal elderly and in Fuchs' dystrophy eyes were 10+/-3, 16+/-2, and 34+/-11 microm, respectively (P<0.001). There was a significant correlation between age and DM thickness only in normal groups. In Fuchs' dystrophy patients, there was a significant correlation between CCT and DM thickness that was not significant for normal groups. Ultra-high-resolution OCT is an

  7. Bone-marrow densitometry: Assessment of marrow space of human vertebrae by single energy high resolution-quantitative computed tomography.

    Science.gov (United States)

    Peña, Jaime A; Thomsen, Felix; Damm, Timo; Campbell, Graeme M; Bastgen, Jan; Barkmann, Reinhard; Glüer, Claus C

    2016-07-01

    Accurate noninvasive assessment of vertebral bone marrow fat fraction is important for diagnostic assessment of a variety of disorders and therapies known to affect marrow composition. Moreover, it provides a means to correct fat-induced bias of single energy quantitative computed tomography (QCT) based bone mineral density (BMD) measurements. The authors developed new segmentation and calibration methods to obtain quantitative surrogate measures of marrow-fat density in the axial skeleton. The authors developed and tested two high resolution-QCT (HR-QCT) based methods which permit segmentation of bone voids in between trabeculae hypothesizing that they are representative of bone marrow space. The methods permit calculation of marrow content in units of mineral equivalent marrow density (MeMD). The first method is based on global thresholding and peeling (GTP) to define a volume of interest away from the transition between trabecular bone and marrow. The second method, morphological filtering (MF), uses spherical elements of different radii (0.1-1.2 mm) and automatically places them in between trabeculae to identify regions with large trabecular interspace, the bone-void space. To determine their performance, data were compared ex vivo to high-resolution peripheral CT (HR-pQCT) images as the gold-standard. The performance of the methods was tested on a set of excised human vertebrae with intact bone marrow tissue representative of an elderly population with low BMD. 86% (GTP) and 87% (MF) of the voxels identified as true marrow space on HR-pQCT images were correctly identified on HR-QCT images and thus these volumes of interest can be considered to be representative of true marrow space. Within this volume, MeMD was estimated with residual errors of 4.8 mg/cm(3) corresponding to accuracy errors in fat fraction on the order of 5% both for GTP and MF methods. The GTP and MF methods on HR-QCT images permit noninvasive localization and densitometric assessment of

  8. Utility of high-resolution computed tomography for predicting risk of sputum smear-negative pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Masanori [Departments of Respiratory Medicine, Faculty of Medical Sciences, University of Fukui, 23 Shimoaizuki Eiheizi-cho, Fukui 910-1193 (Japan)], E-mail: mnakanishi@nifty.ne.jp; Demura, Yoshiki; Ameshima, Shingo [Departments of Respiratory Medicine, Faculty of Medical Sciences, University of Fukui, 23 Shimoaizuki Eiheizi-cho, Fukui 910-1193 (Japan); Kosaka, Nobuyuki [Departments of Radiology, Faculty of Medical Sciences, University of Fukui, 23 Shimoaizuki Eiheizi-cho, Fukui 910-1193 (Japan); Chiba, Yukio [Department of Respiratory Medicine, National Hospital Organization, Fukui Hospital, Tsuruga, Fukui 914-0195 (Japan); Nishikawa, Satoshi [Department of Radiology, National Hospital Organization, Fukui Hospital, Tsuruga, Fukui 914-0195 (Japan); Itoh, Harumi [Departments of Radiology, Faculty of Medical Sciences, University of Fukui, 23 Shimoaizuki Eiheizi-cho, Fukui 910-1193 (Japan); Ishizaki, Takeshi [Departments of Respiratory Medicine, Faculty of Medical Sciences, University of Fukui, 23 Shimoaizuki Eiheizi-cho, Fukui 910-1193 (Japan)

    2010-03-15

    Background: To diagnose sputum smear-negative pulmonary tuberculosis (PTB) is difficult and the ability of high-resolution computed tomography (HRCT) for diagnosing PTB has remained unclear in the sputum smear-negative setting. We retrospectively investigated whether or not this imaging modality can predict risk for sputum smear-negative PTB. Methods: We used HRCT to examine the findings of 116 patients with suspected PTB despite negative sputum smears for acid-fast bacilli (AFB). We investigated their clinical features and HRCT-findings to predict the risk for PTB by multivariate analysis and a combination of HRCT findings by stepwise regression analysis. We then designed provisional HRCT diagnostic criteria based on these results to rank the risk of PTB and blinded observers assessed the validity and reliability of these criteria. Results: A positive tuberculin skin test alone among clinical laboratory findings was significantly associated with an increase of risk of PTB. Multivariate regression analysis showed that large nodules, tree-in-bud appearance, lobular consolidation and the main lesion being located in S1, S2, and S6 were significantly associated with an increased risk of PTB. Stepwise regression analysis showed that coexistence of the above 4 factors was most significantly associated with an increase in the risk for PTB. Ranking of the results using our HRCT diagnostic criteria by blinded observers revealed good utility and agreement for predicting PTB risk. Conclusions: Even in the sputum smear-negative setting, HRCT can predict the risk of PTB with good reproducibility and can select patients having a high probability of PTB.

  9. High-resolution X-ray computed tomography observations of the thermal drying of lump-sized subbituminous coal

    Energy Technology Data Exchange (ETDEWEB)

    Mathews, Jonathan P. [Department of Energy and Mineral Engineering, Pennsylvania State University, University Park, PA (United States); EMS Energy Institute, University Park, PA (United States); Pone, J. Denis N. [ConocoPhilips Technology Center, Bartlesville, Oklahoma (United States); Mitchell, Gareth D.; Halleck, Phillip [EMS Energy Institute, University Park, PA (United States)

    2011-01-15

    Drying of low-rank coals affects: coal cleaning, combustion, comminution, gasification, liquefaction, and in-seam fluid-flow (water, coalbed methane, and carbon dioxide for sequestration/enhanced coalbed methane). To evaluate the extent of drying-induced transitions, 3 lump-sized (approximately 6 x 2 x 2 cm) Powder River Basin subbituminous coal samples were thermally dried in an air-drying coal oven at 50 C over two weeks. A high-resolution industrial X-ray computed tomography scanner was utilized to generate (non-destructively) three-dimensional regional volumetric renderings, as-received and over 3-stages of drying. The lumps had cleats, both open and mineral filled, with a degree of fracture diversity along the longitudinal plane. Comparison of the virtual slice surfaces, at identifiable locations, allowed the induced cracking and shrinkage accompanying the transitions during 19% moisture loss to almost dry to be observed. Under these drying conditions, the heat transfer, and thus extent of drying, proceeded radially inward. With increased drying time the fractures extend and become larger in aperture as the coal shrinks. The major fractures mostly followed the existing cleat system. With additional drying, these cleats widened and the aperture increase propagated deeper into the coal extended into the butt cleats. New fractures were located mostly perpendicular to the cleat fracture surface. The external volume of the coal lumps had limited shrinkage. The axial extent of the shrinkage length (lump edge to lump edge) was on the order of 4-6%, the bulk of the shrinkage being accommodated by the internal shrinkage between cleats. (author)

  10. Automated quantification of three-dimensional subject motion to monitor image quality in high-resolution peripheral quantitative computed tomography

    Science.gov (United States)

    Pauchard, Yves; Ayres, Fábio J.; Boyd, Steven K.

    2011-10-01

    Subject motion during acquisition of high-resolution peripheral quantitative computed tomography (HR-pQCT) results in image artifacts and interferes with quantification of bone architecture used to study bone-related diseases such as osteoporosis. We propose an automatic method to measure physical subject motion that frequently takes place during acquisition. Three measures derived from projection data are proposed to quantify motion artifacts: in-plane translation (εT) and in-plane rotation (εR) utilizing projection moments and longitudinal translation (εz) based on tracking projection profiles. Validation was performed using a phantom containing sections of distal human cadaver radii attached to a mechanical device to precisely control in-plane rotation and longitudinal translation that was intentionally performed during HR-pQCT data acquisition. Motion measured by the new automated technique was compared to the known applied motion, and related to percent errors in morphological parameters quantifying bone properties. It was determined that of the three proposed measures, εT best captured a quantified representation of image quality. εT linearly relates to true physical in-plane translational motion (r2 = 0.95, pmovements and combines well with εT to fully characterize physical motion artifacts. The magnitude of εT corresponds to morphological parameter error and is an excellent basis to select high-quality images. Morphological parameter errors from these experiments confirmed our earlier computer simulations which showed that increased subject motion resulted in artificially higher trabecular number, and artificially lower bone mineral density and cortical thickness. The magnitude and, notably, the uncertainty of the morphological errors increased with increased physical motion, and this impedes a direct linear compensation of parameter errors. The automated method presented provides a basis for consistent and objective quality assurance for HR

  11. Plant tissues in 3D via X-ray tomography: simple contrasting methods allow high resolution imaging.

    Directory of Open Access Journals (Sweden)

    Yannick M Staedler

    Full Text Available Computed tomography remains strongly underused in plant sciences despite its high potential in delivering detailed 3D phenotypical information because of the low X-ray absorption of most plant tissues. Existing protocols to study soft tissues display poor performance, especially when compared to those used on animals. More efficient protocols to study plant material are therefore needed. Flowers of Arabidopsis thaliana and Marcgravia caudata were immersed in a selection of contrasting agents used to treat samples for transmission electron microscopy. Grayscale values for floral tissues and background were measured as a function of time. Contrast was quantified via a contrast index. The thick buds of Marcgravia were scanned to determine which contrasting agents best penetrate thick tissues. The highest contrast increase with cytoplasm-rich tissues was obtained with phosphotungstate, whereas osmium tetroxide and bismuth tatrate displayed the highest contrast increase with vacuolated tissues. Phosphotungstate also displayed the best sample penetration. Furthermore, infiltration with phosphotungstate allowed imaging of all plants parts at a high resolution of 3 µm, which approaches the maximum resolution of our equipment: 1.5 µm. The high affinity of phosphotungstate for vasculature, cytoplasm-rich tissue, and pollen causes these tissues to absorb more X-rays than the surrounding tissues, which, in turn, makes these tissues appear brighter on the scan data. Tissues with different brightness can then be virtually dissected from each other by selecting the bracket of grayscale to be visualized. Promising directions for the future include in silico phenotyping and developmental studies of plant inner parts (e.g., ovules, vasculature, pollen, and cell nuclei via virtual dissection as well as correlations of quantitative phenotypes with omics datasets. Therefore, this work represents a crucial improvement of previous methods, allowing new directions of

  12. Plant tissues in 3D via X-ray tomography: simple contrasting methods allow high resolution imaging.

    Science.gov (United States)

    Staedler, Yannick M; Masson, David; Schönenberger, Jürg

    2013-01-01

    Computed tomography remains strongly underused in plant sciences despite its high potential in delivering detailed 3D phenotypical information because of the low X-ray absorption of most plant tissues. Existing protocols to study soft tissues display poor performance, especially when compared to those used on animals. More efficient protocols to study plant material are therefore needed. Flowers of Arabidopsis thaliana and Marcgravia caudata were immersed in a selection of contrasting agents used to treat samples for transmission electron microscopy. Grayscale values for floral tissues and background were measured as a function of time. Contrast was quantified via a contrast index. The thick buds of Marcgravia were scanned to determine which contrasting agents best penetrate thick tissues. The highest contrast increase with cytoplasm-rich tissues was obtained with phosphotungstate, whereas osmium tetroxide and bismuth tatrate displayed the highest contrast increase with vacuolated tissues. Phosphotungstate also displayed the best sample penetration. Furthermore, infiltration with phosphotungstate allowed imaging of all plants parts at a high resolution of 3 µm, which approaches the maximum resolution of our equipment: 1.5 µm. The high affinity of phosphotungstate for vasculature, cytoplasm-rich tissue, and pollen causes these tissues to absorb more X-rays than the surrounding tissues, which, in turn, makes these tissues appear brighter on the scan data. Tissues with different brightness can then be virtually dissected from each other by selecting the bracket of grayscale to be visualized. Promising directions for the future include in silico phenotyping and developmental studies of plant inner parts (e.g., ovules, vasculature, pollen, and cell nuclei) via virtual dissection as well as correlations of quantitative phenotypes with omics datasets. Therefore, this work represents a crucial improvement of previous methods, allowing new directions of research to be

  13. Possible UIP pattern on high-resolution computed tomography is associated with better survival than definite UIP in IPF patients.

    Science.gov (United States)

    Salisbury, Margaret L; Tolle, Leslie B; Xia, Meng; Murray, Susan; Tayob, Nabihah; Nambiar, Anoop M; Schmidt, Shelley L; Lagstein, Amir; Myers, Jeffery L; Gross, Barry H; Kazerooni, Ella A; Sundaram, Baskaran; Chughtai, Aamer R; Martinez, Fernando J; Flaherty, Kevin R

    2017-10-01

    Idiopathic pulmonary fibrosis (IPF) is a progressive fibrosing lung disease of unknown etiology. Inter-society consensus guidelines on IPF diagnosis and management outline radiologic patterns including definite usual interstitial pneumonia (UIP), possible UIP, and inconsistent with UIP. We evaluate these diagnostic categories as prognostic markers among patients with IPF. Included subjects had biopsy-proven UIP, a multidisciplinary team diagnosis of IPF, and a baseline high-resolution computed tomography (HRCT). Thoracic radiologists assigned the radiologic pattern and documented the presence and extent of specific radiologic findings. The outcome of interest was lung transplant-free survival. IPF patients with a possible UIP pattern on HRCT had significantly longer Kaplan-Meier event-free survival compared to those with definite UIP pattern (5.21 and 3.57 years, respectively, p = 0.002). In a multivariable Cox proportional hazards model adjusted for baseline age, gender, %-predicted FVC, and %-predicted DLCO via the GAP Stage, extent of fibrosis (via the traction bronchiectasis score) and ever-smoker status, possible UIP pattern on HRCT (versus definite UIP) was associated with reduced hazard of death or lung transplant (HR = 0.42, CI 95% 0.23-0.78, p = 0.006). Radiologic diagnosis categories outlined by inter-society consensus guidelines is a widely-reported and potentially useful prognostic marker in IPF patients, with possible UIP pattern on HRCT associated with a favorable prognosis compared to definite UIP pattern, after adjusting for relevant covariates. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. High-resolution Fourier-Domain Optical Coherence Tomography and Microperimetric Findings After Macula-off Retinal Detachment Repair

    Science.gov (United States)

    Smith, Allison J.; Telander, David G.; Zawadzki, Robert J.; Choi, Stacey S.; Morse, Lawrence S.; Werner, John S.; Park, Susanna S.

    2009-01-01

    Objective To evaluate the morphologic changes in the macula of subjects with repaired macula-off retinal detachment (RD) using high-resolution Fourier-domain optical coherence tomography (FD OCT) and to perform functional correlation in a subset of patients using microperimetry (MP-1). Design Prospective observational case series. Participants Seventeen eyes from 17 subjects who had undergone anatomically successful repair for macula-off, rhegmatogenous RD at least 3 months earlier and without visually significant maculopathy on funduscopy. Methods FD OCT with axial and transverse resolution of 4.5 μm and 10 to 15 μm, respectively, was used to obtain rapid serial B-scans of the macula, which were compared with that from Stratus OCT. The FD OCT B-scans were used to create a 3-dimensional volume, from which en face C-scans were created. Among 11 patients, MP-1 was performed to correlate morphologic changes with visual function. Main Outcome Measures Stratus OCT scans, FD OCT scans, and MP-1 data. Results Stratus OCT and FD OCT images of the macula were obtained 3 to 30 months (mean 7 months) postoperatively in all eyes. Although Stratus OCT revealed photoreceptor disruption in 2 eyes (12%), FD OCT showed photoreceptor disruption in 13 eyes (76%). This difference was statistically significant (Pmacula-off RD repair is a common abnormality in the macula that is detected better with FD OCT than Stratus OCT. A good correlation between MP-1 abnormality and presence of photoreceptor disruption or subretinal fluid on FD OCT demonstrates that these anatomic abnormalities contribute to decreased visual function after successful repair. PMID:18672289

  15. High-resolution computed tomography findings from adult patients with Influenza A (H1N1) virus-associated pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Fluminense Federal University, Rio de Janeiro (Brazil); Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)], E-mail: edmarchiori@gmail.com; Zanetti, Glaucia [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)], E-mail: glauciazanetti@gmail.com; Hochhegger, Bruno [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)], E-mail: brunohochhegger@gmail.com; Rodrigues, Rosana Souza [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil); D' OR Institute for Research and Education, Rio de Janeiro (Brazil)], E-mail: rosana.souzarodrigues@gmail.com; Fontes, Cristina Asvolinsque Pantaleao [Fluminense Federal University, Rio de Janeiro (Brazil)], E-mail: cristinasvolinsque@gmail.com; Nobre, Luiz Felipe [Santa Catarina Federal University, Florianopolis (Brazil)], E-mail: luizfelipenobresc@gmail.com; Dias Mancano, Alexandre [Anchieta Hospital, Taguatinga, DF (Brazil)], E-mail: alex.manzano1@gmail.com; Meirelles, Gustavo [Sao Paulo Federal University, Sao Paulo (Brazil)], E-mail: gmeirelles@gmail.com; Irion, Klaus Loureiro [Liverpool Heart and Chest Hospital NHS Trust, Liverpool (United Kingdom); Royal Liverpool and Broadgreen University Hospital NHS, Liverpool (United Kingdom)], E-mail: klaus.irion@btinternet.com

    2010-04-15

    Objective: The aim of this study was to assess the high-resolution computed tomography (HRCT) findings at presentation in patients diagnosed with Influenza A (H1N1) virus-associated pneumonia. Materials and methods: We reviewed the HRCT findings from 20 patients diagnosed with Influenza A (H1N1) and compared their HRCT scans with chest radiographs, obtained on the same day. The imaging studies were obtained 4-9 days after the onset of symptoms. The patients included 11 men and 9 women (ages 24-62 years; mean 42.7 years). All patients had a body temperature greater than 100.4 deg. F (>38 deg. C), tachypnea, and cough. Other common symptoms included diarrhea (60%) and sore throat (30%). The radiographs and HRCT scans were reviewed independently by two observers who reached a consensus decision. Results: The predominant HRCT findings consisted of bilateral ground-glass opacities (n = 12), bilateral areas of consolidation (n = 2), or a mixed bilateral pattern of ground-glass opacities and areas of consolidation (n = 6). The abnormalities were bilateral in all of the 20 patients, had a predominantly sub-pleural distribution in 13 patients, and had a random distribution in the remaining 7 patients. The predominant radiographic findings were consolidations. Normal radiographs were found in 4 out of the 20 patients. Conclusion: HRCT may reveal parenchymal abnormalities in patients with Influenza A (H1N1) infection who have normal findings on radiographs. The predominant HRCT findings were bilateral, peripheral, ground-glass opacities and/or bilateral areas of consolidation. The patients who presented consolidations had more severe clinical course.

  16. High-resolution computed tomography findings of early mucinous adenocarcinomas and their pathologic characteristics in 22 surgically resected cases

    Energy Technology Data Exchange (ETDEWEB)

    Miyata, Naoko, E-mail: n.miyata@scchr.jp [Division of Thoracic Surgery, Shizuoka Cancer Center Hospital, 1007 Shimonagakubo, Nagaizumi, Sunto-gun, Shizuoka 411-8777 (Japan); Endo, Masahiro [Division of Diagnostic Radiology, Shizuoka Cancer Center Hospital (Japan); Nakajima, Takashi [Division of Pathology, Shizuoka Cancer Center Hospital (Japan); Kojima, Hideaki; Maniwa, Tomohiro; Takahashi, Shoji; Isaka, Mitsuhiro [Division of Thoracic Surgery, Shizuoka Cancer Center Hospital, 1007 Shimonagakubo, Nagaizumi, Sunto-gun, Shizuoka 411-8777 (Japan); Kameya, Toru [Division of Pathology, Shizuoka Cancer Center Hospital (Japan); Ohde, Yasuhisa [Division of Thoracic Surgery, Shizuoka Cancer Center Hospital, 1007 Shimonagakubo, Nagaizumi, Sunto-gun, Shizuoka 411-8777 (Japan)

    2015-05-15

    Highlights: • We clinicopathologically reviewed 22 cases of early mucinous adenocarcinoma. • Radiologically, all cases showed solid or part-solid nodules. • Lobular-bounded margins were observed in 7 cases. • The radiological features could be histologically attributed to mucin production. • One-third of the cases were preoperatively misdiagnosed as inflammatory nodules. - Abstract: Background: The pathological criteria of early-stage mucinous adenocarcinoma of the lung have recently been defined; however, its characteristic radiologic imaging findings are still poorly understood. Thus, this study aimed to clarify the radiologic and pathological findings of early-stage mucinous adenocarcinoma. Materials and methods: In this study, we clinicopathologically reviewed 22 cases of surgically resected mucinous adenocarcinoma in situ (AIS) and minimal invasive adenocarcinoma (MIA), and attempted to elucidate the characteristic radiologic features of early mucinous adenocarcinomas using high-resolution computed tomography (HRCT). Results: Radiologically, the mean value of the maximum diameter of 22 tumours was 2.1 cm (range, 1.0–2.9 cm). Based on the HRCT findings, the tumours were divided into part-solid ground glass nodules (n = 11) and solid nodules (n = 11). The mean CT attenuation value was 25.7 HU (range, 17–35 HU). All tumours, except 3 tumours pathologically diagnosed as AIS, showed air-containing features. According to the preoperative CT findings, 7 (35%) cases were diagnosed as inflammatory nodules. Of these, 4 cases had lobular-bounded margins, and 3 showed vaguely outlined ground glass shadows. Conclusion: The characteristic HRCT findings of mucinous AIS and MIA were solid or part-solid nodules with air-containing spaces. However, some AIS and MIA nodules showed lobular-bounded margins or marginally vaguely outlined ground glass shadows, and were difficult to differentiate from inflammatory nodules.

  17. Aging adult skull vaults by applying the concept of fractal geometry to high-resolution computed tomography images.

    Science.gov (United States)

    Obert, Martin; Seyfried, Maren; Schumacher, Falk; Krombach, Gabriele A; Verhoff, Marcel A

    2014-09-01

    Aging human remains is a critical issue in anthropology and forensic medicine, and the search for accurate, new age-estimation methods is ongoing. In our study, we, therefore, explored a new approach to investigate a possible correlation between age-at-death (aad) and geometric irregularities in the bone structure of human skull caps. We applied the concept of fractal geometry and fractal dimension D analysis to describe heterogeneity within the bone structure. A high-resolution flat-panel computed tomography scanner (eXplore Locus Ultra) was used to obtain 229,500 images from 221 male and 120 female (total 341) European human skulls. Automated image analysis software was developed to evaluate the fractal dimension D, using the mass radius method. The frontal and the occipital portions of the skull caps of adult females and males were investigated separately. The age dependence of the fractal dimension D was studied by correlation analysis, and the prediction accuracy of age-at-death (aad) estimates for individual observations was calculated. D values for human skull caps scatter strongly as a function of age. We found sex-dependent correlation coefficients (CC) between D and age for adults (females CC=-0.67; males CC=-0.05). Prediction errors for aad estimates for individual observations were in the range of ±18 years at a 75% confidence interval. The detailed quantitative description of age-dependent irregularities in the bone microarchitecture of skull vaults through fractal dimension analysis does not, as we had hoped, enable a new aging method. Severe scattering of the data leads to an estimation error that is too great for this method to be of practical relevance in aad estimates. Thus, we disclosed an interesting sex difference. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Role of high resolution optical coherence tomography in diagnosing ocular surface squamous neoplasia with coexisting ocular surface diseases.

    Science.gov (United States)

    Atallah, Marwan; Joag, Madhura; Galor, Anat; Amescua, Guillermo; Nanji, Afshan; Wang, Jianhua; Perez, Victor L; Dubovy, Sander; Karp, Carol L

    2017-10-01

    Coexistence of an ocular surface disease can mask the typical features of ocular surface squamous neoplasia (OSSN). The purpose of this study was to evaluate high resolution optical coherence tomography (HR-OCT) as an adjunct in the detection and differentiation of OSSN within coexisting ocular surface pathologies. Retrospective study of 16 patients with ocular surface disease and lesions suspicious for OSSN that were evaluated with HR-OCT. HR-OCT images of the lesions were taken to look for evidence of OSSN. Biopsies were performed in all cases, and the HR-OCT findings were compared to the histological results. Of the 16 patients with OSSN and a coexisting ocular surface disease, 12 were found to have OSSN by HR-OCT and all were subsequently confirmed by biopsy. Two patients had OSSN with rosacea, one with pingueculum, two within pterygia, one with Salzmann' nodular degeneration, six with limbal stem cell deficiency (LSCD)/scarring. In all 12 cases HR-OCT images revealed classical findings of hyper-reflective, thickened epithelium and an abrupt transition from normal to abnormal epithelium. OSSN was ruled out by HR-OCT in four cases (2 Salzmann's, 1 mucous membrane pemphigoid, and 1 LSCD). Negative findings were confirmed by biopsy. HR-OCT was used to follow resolution of the OSSN in positive cases, and it detected recurrence in 1 case. While histopathology is the gold standard in the diagnosis of OSSN, HR-OCT can be used to noninvasively detect the presence of OSSN in patients with coexisting ocular conditions. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Comparison of chest radiography and high-resolution computed tomography findings in early and low-grade coal worker's pneumoconiosis.

    Science.gov (United States)

    Savranlar, Ahmet; Altin, Remzi; Mahmutyazicioğlu, Kamran; Ozdemir, Hüseyin; Kart, Levent; Ozer, Tülay; Gündoğdu, Sadi

    2004-08-01

    High-resolution computed tomography (HRCT) is more sensitive than chest X-ray (CXR) in the depiction of parenchymal abnormalities. We aimed to present and compare CXR and HRCT findings in coal workers with and without early and low-grade coal worker's pneumoconiosis (CWP). 71 coal workers were enrolled in this study. All workers were male. The CXR and HRCT of those workers were obtained and graded by two trained readers. HRCT's were graded according to Hosoda and Shida's Japanese classification. After grading, 67 workers with CXR profusion 0/0-2/2 were included in the study. Four patients with major opacity were excluded. Profusion 0/1 to 1/1 cases were accepted as early and profusion 1/2 and 2/2 cases as low-grade pneumoconiosis. Discordance between CXR and HRCT was high. Discordance rate was found higher in the early pneumoconiosis cases with negative CXR than low-grade pneumoconiosis (60, 36 and 8%, respectively). When coal miners with normal CXR were evaluated by HRCT, six out of 10 cases were diagnosed as positive. In low-grade pneumoconiosis group, the number of patients with positive CXR but negative HRCT were low in comparison to patients with CXR negative and early pneumoconiosis findings. Most of the CXR category 0 patients (10/16) were diagnosed as category 1 by HRCT. Eleven cases diagnosed as CXR category 1 were diagnosed as category 0 (7/11) and category 2 (4/11) by HRCT. In CXR category 2 (eight cases), there were four cases diagnosed as category 1 by HRCT. Discordance between CXR and HRCT was high, especially for CXR negative and early pneumoconiosis cases. The role of CXR in screening coal workers to detect early pneumoconiosis findings should be questioned. We suggest using HRCT as a standard screening method instead of CXR to distinguish between normal and early pneumoconiosis.

  20. Spectrum of High Resolution Computed Tomography Findings in Occupational Lung Disease: Experience in a Tertiary Care Institute

    Directory of Open Access Journals (Sweden)

    Satija Bhawna

    2013-01-01

    Full Text Available Objective: To study the spectrum of high resolution computed tomography (HRCT findings in occupational lung disease in industrial workers and to assess the utility of International classification of HRCT for occupational and environmental respiratory diseases (ICHOERD. Materials and Methods: Retrospective analysis of radiological data (radiographs and computed tomography chest scans gathered over a period of 3 years (January 2010- December 2012 of industrial workers in an organised sector who presented with respiratory complaints. The HRCT findings were evaluated using ICHOERD. Results: There were 5 females and 114 males in the study, with a mean age of 49 years. These workers were exposed to different harmful agents including silica, asbestos, cotton dust, metal dust, iron oxide, organic dust, rubber fumes, plastic fumes, acid fumes, and oil fumes. There were 10 smokers in the study. The radiograph of chest was normal in 53 patients. 46% of these normal patients (21.8% of total demonstrated positive findings on HRCT. When the radiograph was abnormal, HRCT provided more accurate information and excluded the other diagnosis. The HRCT findings were appropriately described using the ICHOERD. Bronchiectasis was the most common finding (44.5% with mild central cylindrical bronchiectasis as the most common pattern. Pleural thickening was seen in 41 patients (34.5%. Enlarged hilar or mediastinal lymphnodes were seen in 10 patients (8.4% with egg-shell calcification in 1 patient exposed to silica. Bronchogenic carcinoma was seen in 1 patient exposed to asbestos. Conclusions: Occupational lung disease is a common work related condition in industrial workers even in the organized sector. Though chest radiograph is the primary diagnostic tool, HRCT is the undisputed Gold Standard for evaluation of these patients. Despite the disadvantage of radiation exposure, low dose CT may serve as an important tool for screening and surveillance. The ICHOERD is a

  1. Status of routine post-mortem computerized tomography in Odense, Denmark

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2008-01-01

      In February 2006 a dual slice CT scanner was installed at the Institute of Forensic Medicine in Odense, Denmark. Since that time a CT-scanning has been performed on all bodies prior to autopsy. This article provides an overview of the experience gained.  We found that computerized tomography...... rarely is a substitute for autopsy, but may contribute with important new information in many cases such as identifications (including mass-disasters), battered child, gunshot wounds, traffic accidents and air embolism. Computerized tomography provides documentation in digital form - easily stored...

  2. Positron emission tomography / computerized tomography evaluation of primary Hodgkin's disease of liver.

    Science.gov (United States)

    Gota, V S; Purandare, N C; Gujral, S; Shah, S; Nair, R; Rangarajan, V

    2009-01-01

    Occurrence of primary Hodgkin's lymphoma (PHL) of the liver is extremely rare. We report on a case of a 60-year-old male who presented with liver mass and B-symptomatology. Hepatoma or hepatic metastasis from a gastrointestinal primary was initially suspected. Tumor markers like AFP, CEA, Total PSA, and CA-19.9 were within normal limits. Positron Emission Tomography / Computerized Tomography (PET/CT) revealed a large hepatic lesion and a nodal mass in the porta hepatis. A liver biopsy was consistent with Hodgkin's lymphoma. There was complete regression of the hepatic lesion and evidence of shrinkage of the nodal mass following four cycles of chemotherapy. 18F Fluro -de-oxy Glucose (FDG) PET / CT in this case helped in establishing a primary hepatic lymphoma by demonstrating the absence of pathologically hypermetabolic foci in any other nodes or organs. PET / CT scan is a useful adjunct to conventional imaging and histopathology, not only to establish the initial diagnosis, but also to monitor treatment response in PHL.

  3. Micro-radiography and micro-computerized tomography with absorption and phase contrast for materials characterization; Mikro-Radiografie und Mikro-Computertomografie mit Absorptions- und Phasenkontrast fuer die Materialcharakterisierung

    Energy Technology Data Exchange (ETDEWEB)

    Kastner, Johann [FH Oberoesterreich, Wels (Austria)

    2017-08-01

    The contribution describes modern techniques in micro-radiography and micro-computerized tomography for materials characterization using absorption and phase contrast. Using micro- and nano-focus tubes and adequate high.-resolution detectors it is possible to reach resolutions significantly below 1 micron. The CT technology allows in-situ deformation testing to study the damaging mechanism of materials. The application of the Talbot-Lau interferometer with CT a differential phase contrast tomography is available. Dark-field tomography is used to study individual carbon fiber bundles in carbon fiber reinforced laminates.

  4. Diagnosis of asbestosis by a time expanded wave form analysis, auscultation and high resolution computed tomography: a comparative study.

    Science.gov (United States)

    al Jarad, N; Strickland, B; Bothamley, G; Lock, S; Logan-Sinclair, R; Rudd, R M

    1993-04-01

    Crackles are a prominent clinical feature of asbestosis and may be an early sign of the condition. Auscultation, however, is subjective and interexaminer disagreement is a problem. Computerised lung sound analysis can visualise, store, and analyse lung sounds and disagreement on the presence of crackles is minimal. High resolution computed tomography (HRCT) is superior to chest radiography in detecting early signs of asbestosis. The aim of this study was to compare clinical auscultation, time expanded wave form analysis (TEW), chest radiography, and HRCT in detecting signs of asbestosis in asbestos workers. Fifty three asbestos workers (51 men and two women) were investigated. Chest radiography and HRCT were assessed by two independent readers for detection of interstitial opacities. HRCT was performed in the supine position with additional sections at the bases in the prone position. Auscultation for persistent fine inspiratory crackles was performed by two independent examiners unacquainted with the diagnosis. TEW analysis was obtained from a 33 second recording of lung sounds over the lung bases. TEW and auscultation were performed in a control group of 13 subjects who had a normal chest radiograph. There were 10 current smokers and three previous smokers. In asbestos workers the extent of pulmonary opacities on the chest radiograph was scored according to the International Labour Office (ILO) scale. Patients were divided into two groups: 21 patients in whom the chest radiograph was > 1/0 (group 1) and 32 patients in whom the chest radiograph was scored 1/0 auscultation and TEW revealed mid to late inspiratory crackles in all patients, whereas HRCT revealed gravity dependent subpleural lines in one patient and signs of definite interstitial fibrosis in the rest. In normal subjects crackles different from those detected in asbestosis were detected by TEW in three subjects but only in one subject by auscultation. These were early, fine inspiratory crackles. Mid to

  5. Paracoccidioidomycosis: high-resolution computed tomography - anatomo-pathological correlation; Paracoccidioidomicose: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson; Muniz, Maria Angelica Soares; Santos, Maria Lucia de Oliveira [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Radiologia; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Patologia; Capone, Domenico [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Pneumologia

    2000-12-01

    We reviewed the high-resolution computed tomography scans of 13 patients with paracoccidioidomycosis and correlated the findings with the anatomo-pathological findings of 5 patients. The most frequent findings observed were thickening of the interlobular septa, emphysema, ground glass areas, thickening of bronchial walls, tracheal dilatation, nodules, cavities and evidence of fibrosing disease such as architectural distortion, parenchymatous bands, spicular pleural thickening, intralobular reticulate and thickening with distortion off the axial interstitium. (author)

  6. Can duplex Doppler ultrasound replace computerized tomography in staging patients with renal cell carcinoma?

    NARCIS (Netherlands)

    Bos, SD; Mensink, HJA

    The purpose of this study was to evaluate the accuracy and reliability of duplex Doppler ultrasound (US) and computerized tomography (CT) in staging patients with renal cell carcinoma (RCC). Sixty-six patients were evaluated pre-operatively with duplex Doppler ultrasound and CT. The results were

  7. Computerized tomography (the EMI Scanner): a comparison with pneumoencephalography and ventriculography.

    Science.gov (United States)

    Gawler, J; Du Boulay, G H; Bull, J W; Marshall, J

    1976-01-01

    Computerized tomography, using the EMI Scanner, allows the diagnosis of cerebral atrophy or hydrocephalus to be made with the same degree of accuracy as conventional neuroradiological methods. Ventricular measurements made on EMI scans have been compared with those from pneumoencephalograms and ventriculograms. A range of normal ventricular measurements for the EMI scan is suggested. Images PMID:1084413

  8. High-Resolution Computed Tomography Examinations for Chronic Suppurative Lung Disease in Early Childhood: Radiation Exposure and Image Quality Evaluations With Iterative Reconstruction Algorithm Use.

    Science.gov (United States)

    Smarda, Magdalini; Efstathopoulos, Efstathios; Mazioti, Argyro; Kordolaimi, Sofia; Ploussi, Agapi; Priftis, Konstantinos; Kelekis, Nikolaos; Alexopoulou, Efthymia

    2016-08-01

    High radiosensitivity of children undergoing repetitive computed tomography examinations necessitates the use of iterative reconstruction algorithms in order to achieve a significant radiation dose reduction. The goal of this study is to compare the iDose iterative reconstruction algorithm with filtered backprojection in terms of radiation exposure and image quality in 33 chest high-resolution computed tomography examinations performed in young children with chronic bronchitis. Fourteen patients were scanned using the filtered backprojection protocol while 19 patients using the iDose protocol and reduced milliampere-seconds, both on a 64-detector row computed tomography scanner. The iDose group images were reconstructed with different iDose levels (2, 4, and 6). Radiation exposure quantities were estimated, while subjective and objective image qualities were evaluated. Unpaired t tests were used for data statistical analysis. The iDose application allowed significant effective dose reduction (about 80%). Subjective image quality evaluation showed satisfactory results even with iDose level 2, whereas it approached excellent image with iDose level 6. Subjective image noise was comparable between the 2 groups with the use of iDose level 4, while objective noise was comparable between filtered backprojection and iterative reconstruction level 6 images. The iDose algorithm use in pediatric chest high-resolution computed tomography reduces radiation exposure without compromising image quality. Further evaluation with iterative reconstruction algorithms is needed in order to establish high-resolution computed tomography as the gold standard low-dose method for children suffering from chronic lung diseases. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  9. Significance of computerized tomography and nasal cytology in the ...

    African Journals Online (AJOL)

    Ehab

    inflammatory products and mouth breathing might also cause increased water and heat loss in the lower airways thereby contributing to asthmatic symptoms8. This work is aimed at identifying the significance of computed tomography scanning, nasal cytology examination, and serum total IgE assay in the diagnosis of ...

  10. Emission computerized myocardial tomography with the 7-pinhole collimator

    Energy Technology Data Exchange (ETDEWEB)

    Sochor, H.; Pachinger, O.; Ogris, E.; Probst, P.; Joskowicz, G.; Kaindl, F. (Vienna Univ. (Austria). Kardiologische Klinik)

    1983-01-01

    89 patients (78 with coronary artery disease, 11 normals) were studied comparatively with Tl-201 planar myocardial scintigraphy and 7-pinhole emission tomography with a mobile gamma-camera. In 46 patients stress studies were performed, the other studies were performed as resting protocols. In 13 patients a correlation of scintigraphically determined infarct size calculated from the Tl-201 tomograms with CK and CK-MB values (maximum values) in the acute infarction period was performed. 17 patients having undergone intracoronary streptolysis were studied to investigate the effect of this intervention. In patients without previous myocardial infarction (n=35) sensitivity of 7-pinhole tomography was significantly superior over planar reading of images (83% for qualitative evaluation, 91% for quantitative analysis). In patients with previous myocardial infarction (n=26) comparative sensitivities were not significantly different, although slightly higher, neverthelesss the fraction of questionable findings was reduced from 9 to 4%, furthermore in 31% an additional information concerning size or localization could be obtained from the tomograms. Predictive diagnostic accuracy was highest for quantitative 7-pinhole tomography (91%) but not significantly different from qualitative tomography but higher than for planar imaging. Specificities of all methods were comparable. In patients during the acute phase of myocardial infarction a significant correlation (r = 0.76 for CK, r = 0.78 for CK-MB, p < 0.01) was obtained with enzymatic markers of infarct size. In the group after intracoronary streptolysis 7-pinhole tomography was able to demonstrate a quantitative reduction of thallium infarct size in patients after successful lysis (23.5% vs 48.7%, p < 0.01).

  11. Pulmonary lymphomas: high-resolution computed tomography and anatomopathological correlation; Linfomas pulmonares: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@zipmail.com.br; Valiant, Paulo Marcos [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Dept. de Patologia; Gutierrez, Ana Luiza Telles de Miranda; Bodanese, Larissa [Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil). Dept. de Radiologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto, SP (Brazil)

    2002-02-01

    This paper describes the high-resolution computed tomography and anatomopathological findings of pulmonary lymphomas. We studied the chest high-resolution computed tomographs and histopathological data of 10 patients with biopsy-proven non-Hodgkin's or Hodgkin's disease. The most common radiologic findings in this series were areas of consolidation with air-bronchogram (n = 8). Others findings included multiple pulmonary nodules (n = 4), thickening of bronchovascular bundles (n =3) and foci of ground-glass attenuation (n =2). The present series results are consistent with the current available literature on radiographic appearance of the disease. The pathological correspondence of the areas of air space consolidation was alveolar filling by neoplastic cells, the thickening of bronchovascular bundles was secondary to lymphomatous cells infiltrates, and the areas of ground-glass attenuation corresponded to alveolar septal infiltration by these cells. (author)

  12. [Paranasal sinusitis: study with conventional and spiral computerized tomography].

    Science.gov (United States)

    Sartoni Galloni, S; Burzi, M; Lipparini, M; Gigli, F; Burci, P; Stamati, R; Guidarelli, G

    1996-01-01

    This study was aimed at comparing the diagnostic value of conventional computed tomography (CCT) with that of spiral computed tomography (SCT) in sinonasal structures and ostiomeatal complex in thirty patients with inflammatory disease. Ten patients were examined with CCT (3-mm slice thickness, 120 kV, 100 mA, 2-s gantry rotation) and 20 were examined with SCT (3-mm slice thickness, 120 kV, 200 mA, 1-s gantry rotation and computed image reconstruction every 3 mm); table gain was 3 mm (Pitch 1) in 10 patients and 5 mm (Pitch 1.6) in the other 10 patients. With the latter study protocol, diagnostic image quality was the same as with the other two protocols. Moreover, examination time was reduced, with increased patients' comfort; the exposure dose and X-ray tube overload were also reduced, with increased system yield.

  13. Imaging results of multi-modal ultrasound computerized tomography system designed for breast diagnosis.

    Science.gov (United States)

    Opieliński, Krzysztof J; Pruchnicki, Piotr; Gudra, Tadeusz; Podgórski, Przemysław; Kurcz, Jacek; Kraśnicki, Tomasz; Sąsiadek, Marek; Majewski, Jarosław

    2015-12-01

    Nowadays, in the era of common computerization, transmission and reflection methods are intensively developed in addition to improving classical ultrasound methods (US) for imaging of tissue structure, in particular ultrasound transmission tomography UTT (analogous to computed tomography CT which uses X-rays) and reflection tomography URT (based on the synthetic aperture method used in radar imaging techniques). This paper presents and analyses the results of ultrasound transmission tomography imaging of the internal structure of the female breast biopsy phantom CIRS Model 052A and the results of the ultrasound reflection tomography imaging of a wire sample. Imaging was performed using a multi-modal ultrasound computerized tomography system developed with the participation of a private investor. The results were compared with the results of imaging obtained using dual energy CT, MR mammography and conventional US method. The obtained results indicate that the developed UTT and URT methods, after the acceleration of the scanning process, thus enabling in vivo examination, may be successfully used for detection and detailed characterization of breast lesions in women. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Calcification of all four parathyroid glands in a hemodialysis patient with secondary hyperparathyroidism revealed by computerized tomography.

    Science.gov (United States)

    Peces, R; Rodríguez, M; González, F; Ablanedo, P

    2001-09-01

    This report describes the parathyroid scan, computerized tomography and histologic findings in a young female hemodialysis patient with severe secondary hyperparathyroidism. These findings included hyperplasia and calcification of all four parathyroid glands.

  15. An Anatomical Study of Maxillary-Zygomatic Complex Using Three-Dimensional Computerized Tomography-Based Zygomatic Implantation

    National Research Council Canada - National Science Library

    2017-01-01

    Objective. To obtain anatomical data of maxillary-zygomatic complex based on simulating the zygomatic implantation using cadaver heads and three-dimensional computerized tomography (3D-CT). Methods...

  16. Patient and institutional characteristics associated with initial computerized tomography in children presenting to the emergency department with kidney stones.

    Science.gov (United States)

    Ziemba, Justin B; Canning, Douglas A; Lavelle, Jane; Kalmus, Angela; Tasian, Gregory E

    2015-05-01

    Professional associations recommend ultrasound as the initial imaging study in children with suspected nephrolithiasis but computerized tomography remains frequently used. We identified patient and institutional characteristics associated with computerized tomography as the first imaging study in children with nephrolithiasis diagnosed in the emergency department. We performed a cross-sectional study of children 2 to 18 years old with nephrolithiasis who were referred to a freestanding pediatric hospital from 2003 to 2012. We identified the imaging modality first used to evaluate the child. Medical directors at the emergency department where children were first evaluated were sent a questionnaire to ascertain emergency department characteristics. Multivariate hierarchical logistic regression models were used to determine patient and institutional characteristics associated with initial computerized tomography. Of 536 eligible children 323 (60.2%) were evaluated at emergency departments from which surveys were returned. Of the 323 children 238 (71%) underwent computerized tomography as initial imaging. Ultrasound was available at all emergency departments. Older patient age was associated with higher initial computerized tomography use (OR 1.09, 95% CI 1.04-1.16). A more recent year of diagnosis (OR 0.80, 95% CI 0.72-0.88) and a clinical care pathway that used ultrasound as initial imaging (OR 0.29, 95% CI 0.01-0.38) were associated with lower initial computerized tomography use. A clinical care pathway in the emergency department was the only institutional characteristic associated with lower computerized tomography use. Future studies are needed to determine whether care pathways using ultrasound for initial imaging in children with suspected nephrolithiasis would decrease inappropriate computerized tomography and improve adherence to national guidelines. Copyright © 2015. Published by Elsevier Inc.

  17. Development of a sub-cm high resolution ion Doppler tomography diagnostics for fine structure measurement of guide field reconnection in TS-U

    Science.gov (United States)

    Tanabe, Hiroshi; Koike, Hideya; Hatano, Hironori; Hayashi, Takumi; Cao, Qinghong; Himeno, Shunichi; Kaneda, Taishi; Akimitsu, Moe; Sawada, Asuka; Ono, Yasushi

    2017-10-01

    A new type of high-throughput/high-resolution 96CH ion Doppler tomography diagnostics has been developed using ``multi-slit'' spectroscopy technique for detailed investigation of fine structure formation during high guide field magnetic reconnection. In the last three years, high field merging experiment in MAST pioneered new frontiers of reconnection heating: formation of highly peaked structure around X-point in high guide field condition (Bt > 0.3 T), outflow dissipation under the influence of better plasma confinement to form high temperature ring structure which aligns with closed flux surface of toroidal plasma, and interaction between ion and electron temperature profile during transport/confinement phase to form triple peak structure (τeiE 4 ms). To investigate more detailed mechanism with in-situ magnetic measurement, the university of Tokyo starts the upgrade of plasma parameters and spatial resolution of optical diagnostics as in MAST. Now, a new type of high-throughput/high-resolution 96CH ion Doppler tomography diagnostics system construction has been completed and it successfully resolved fine structure of ion heating downstream, aligned with closed flux surface formed by reconnected field. This work was supported by JSPS KAKENHI Grant Numbers 15H05750, 15K14279 and 17H04863.

  18. A computerized tomography system for transcranial ultrasound imaging.

    Science.gov (United States)

    Tang, Sai Chun; Clement, Gregory T

    Hardware for tomographic imaging presents both challenge and opportunity for simplification when compared with traditional pulse-echo imaging systems. Specifically, point diffraction tomography does not require simultaneous powering of elements, in theory allowing just a single transmit channel and a single receive channel to be coupled with a switching or multiplexing network. In our ongoing work on transcranial imaging, we have developed a 512-channel system designed to transmit and/or receive a high voltage signal from/to arbitrary elements of an imaging array. The overall design follows a hierarchy of modules including a software interface, microcontroller, pulse generator, pulse amplifier, high-voltage power converter, switching mother board, switching daughter board, receiver amplifier, analog-to-digital converter, peak detector, memory, and USB communication. Two pulse amplifiers are included, each capable of producing up to 400Vpp via power MOSFETS. Switching is based around mechanical relays that allow passage of 200V, while still achieving switching times of under 2ms, with an operating frequency ranging from below 100kHz to 10MHz. The system is demonstrated through ex vivo human skulls using 1MHz transducers. The overall system design is applicable to planned human studies in transcranial image acquisition, and may have additional tomographic applications for other materials necessitating a high signal output.

  19. A comparative study of high-resolution cone beam computed tomography and charge-coupled device sensors for detecting caries.

    Science.gov (United States)

    Young, S M; Lee, J T; Hodges, R J; Chang, T-L; Elashoff, D A; White, S C

    2009-10-01

    Conventional radiographic imaging of teeth underestimates the presence of caries. The objective of this study was to compare the efficacy of high-resolution cone beam CT (CBCT) images and conventional charge-coupled device (CCD) images for detecting proximal and occlusal caries. Non-restored, extracted human permanent premolar and molar teeth were mounted and then imaged with a 3DX Accuitomo and a CCD. We selected 92 occlusal and 100 proximal surfaces for raters to score. Of these, 36 and 25, respectively, had lesions extending into dentin. Using a five-step confidence scale, eight practising dentists evaluated the images for the presence of caries in dentin using both modalities. Actual presence and extent of caries was established with microCT imaging. For proximal surface lesions extending into dentin, the average sensitivity score using 3DX images (0.61) was almost twice that of CCD images (0.33) and the difference was significant. The specificity values for both systems were high and not significantly different from each other. For occlusal surfaces, raters detected significantly more lesions in the enamel or dentin when using the 3DX images than when using CCD images. However, the raters also had significantly lower average specificity scores for the 3DX images compared with the CCD images for lesions at both depths. Practising dentists were able to improve their detection of proximal-surface caries extending into the dentin, but not occlusal caries, using 3DX high-resolution cone beam CT images compared with CCD images.

  20. Plant Tissues in 3D via X-Ray Tomography: Simple Contrasting Methods Allow High Resolution Imaging

    OpenAIRE

    Yannick M Staedler; David Masson; Jürg Schönenberger

    2013-01-01

    Computed tomography remains strongly underused in plant sciences despite its high potential in delivering detailed 3D phenotypical information because of the low X-ray absorption of most plant tissues. Existing protocols to study soft tissues display poor performance, especially when compared to those used on animals. More efficient protocols to study plant material are therefore needed. Flowers of Arabidopsis thaliana and Marcgravia caudata were immersed in a selection of contrasting agents ...

  1. Evaluation of the absorbed dose in odontological computerized tomography; Avaliacao da dose absorvida em tomografia computadorizada odontologica

    Energy Technology Data Exchange (ETDEWEB)

    Legnani, Adriano; Schelin, Hugo R.; Rocha, Anna Silvia P.S. da, E-mail: schelin@utfpr.edu.b, E-mail: anna@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Khoury, Helen J., E-mail: khoury@ufpe.b [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2011-10-26

    This paper evaluated the absorbed dose at the surface entry known as 'cone beam computed tomography' (CBCT) in odontological computerized tomography. Examination were simulated with CBCT for measurements of dose. A phantom were filled with water, becoming scatter object of radiation. Thermoluminescent dosemeters were positioned on points correspondent to eyes and salivary glands

  2. Paracoccidioidomicose pulmonar: aspectos na tomografia computadorizada de alta resolução High-resolution computed tomography findings in pulmonary paracoccidioidomycosis

    Directory of Open Access Journals (Sweden)

    Maria Angélica Soares Muniz

    2002-06-01

    Full Text Available O comprometimento pulmonar na paracoccidioidomicose é muito freqüente, podendo até ser a única manifestação da doença. Neste trabalho são analisados os aspectos encontrados nas tomografias computadorizadas de alta resolução do tórax de 30 pacientes com paracoccidioidomicose confirmada. Por meio desta análise foram determinados os achados mais comuns e suas formas de apresentação e distribuição nos pulmões. Os aspectos mais freqüentemente observados foram: espessamento esparso de septos interlobulares (96,7%, opacidades em vidro fosco (66,7%, nódulos (60%, aumento irregular do espaço aéreo (enfisema paracicatricial (56,7%, espessamento de paredes brônquicas (46,7%, espessamento pleural (36,7%, cavidades (36,7%, dilatação da traquéia (33,3%, distorção arquitetural (30%, consolidação do espaço aéreo (30%, bandas parenquimatosas (23,3%, reticulado intralobular (13,3% e espessamento irregular do interstício axial peri-hilar (10%. A radiografia do tórax apresenta limitada capacidade de avaliar doenças pulmonares difusas, tornando a tomografia computadorizada de alta resolução do tórax essencial para avaliação dos pacientes com paracoccidioidomicose pulmonar.Pulmonary disease in paracoccidioidomycosis is very common and in some cases can be the sole manifestation of the disease. We studied the findings observed in 30 patients with pulmonary paracoccidioidomycosis submitted to high-resolution computed tomography in order to determine the most frequent findings, presentation patterns and distribution of paracoccidioidomycosis lesions in the lungs. The most frequent findings observed on high-resolution computed tomography were: interlobular septal thickening (96.7%, ground-glass opacities (66.7%, nodules (60%, irregular air-space enlargement (56.7%, bronchial wall thickening (46.7%, pleural thickening (36.7%, cavitation (36.7%, tracheal dilatation (33.3%, architectural distortion (30%, air-space consolidation (30

  3. Endoscopic high-resolution auto fluorescence imaging and optical coherence tomography of airways in vivo (Conference Presentation)

    Science.gov (United States)

    Pahlevaninezhad, Hamid; Lee, Anthony; Hohert, Geoffrey; Schwartz, Carley; Shaipanich, Tawimas; Ritchie, Alexander J.; Zhang, Wei; MacAulay, Calum E.; Lam, Stephen; Lane, Pierre M.

    2016-03-01

    In this work, we present multimodal imaging of peripheral airways in vivo using an endoscopic imaging system capable of co-registered optical coherence tomography and autofluorescence imaging (OCT-AFI). This system employs a 0.9 mm diameter double-clad fiber optic-based catheter for endoscopic imaging of small peripheral airways. Optical coherence tomography (OCT) can visualize detailed airway morphology in the lung periphery and autofluorescence imaging (AFI) can visualize fluorescent tissue components such as collagen and elastin, improving the detection of airway lesions. Results from in vivo imaging of 40 patients indicate that OCT and AFI offer complementary information that may increase the ability to identify pulmonary nodules in the lung periphery and improve the safety of biopsy collection by identifying large blood vessels. AFI can rapidly visualize in vivo vascular networks using fast scanning parameters resulting in vascular-sensitive imaging with less breathing/cardiac motion artifacts compared to Doppler OCT imaging. By providing complementary information about structure and function of tissue, OCT-AFI may improve site selection during biopsy collection in the lung periphery.

  4. Graphics processing unit accelerated optical coherence tomography processing at megahertz axial scan rate and high resolution video rate volumetric rendering.

    Science.gov (United States)

    Jian, Yifan; Wong, Kevin; Sarunic, Marinko V

    2013-02-01

    In this report, we describe how to highly optimize a computer unified device architecture based platform to perform real-time processing of optical coherence tomography interferometric data and three-dimensional (3-D) volumetric rendering using a commercially available, cost-effective, graphics processing unit (GPU). The maximum complete attainable axial scan processing rate, including memory transfer and displaying B-scan frame, was 2.24 MHz for 16 bits pixel depth and 2048 fast Fourier transform size; the maximum 3-D volumetric rendering rate, including B-scan, en face view display, and 3-D rendering, was ~23 volumes/second (volume size: 1024×256×200). To the best of our knowledge, this is the fastest processing rate reported to date with a single-chip GPU and the first implementation of real-time video-rate volumetric optical coherence tomography (OCT) processing and rendering that is capable of matching the acquisition rates of ultrahigh-speed OCT.

  5. Graphics processing unit accelerated optical coherence tomography processing at megahertz axial scan rate and high resolution video rate volumetric rendering

    Science.gov (United States)

    Jian, Yifan; Wong, Kevin; Sarunic, Marinko V.

    2013-02-01

    In this report, we describe how to highly optimize a computer unified device architecture based platform to perform real-time processing of optical coherence tomography interferometric data and three-dimensional (3-D) volumetric rendering using a commercially available, cost-effective, graphics processing unit (GPU). The maximum complete attainable axial scan processing rate, including memory transfer and displaying B-scan frame, was 2.24 MHz for 16 bits pixel depth and 2048 fast Fourier transform size; the maximum 3-D volumetric rendering rate, including B-scan, en face view display, and 3-D rendering, was ˜23 volumes/second (volume size: 1024×256×200). To the best of our knowledge, this is the fastest processing rate reported to date with a single-chip GPU and the first implementation of real-time video-rate volumetric optical coherence tomography (OCT) processing and rendering that is capable of matching the acquisition rates of ultrahigh-speed OCT.

  6. High resolution aquifer characterization using crosshole GPR full-waveform tomography: Comparison with direct-push and tracer test data

    Science.gov (United States)

    Gueting, Nils; Vienken, Thomas; Klotzsche, Anja; van der Kruk, Jan; Vanderborght, Jan; Caers, Jef; Vereecken, Harry; Englert, Andreas

    2017-01-01

    Limited knowledge about the spatial distribution of aquifer properties typically constrains our ability to predict subsurface flow and transport. Here we investigate the value of using high resolution full-waveform inversion of cross-borehole ground penetrating radar (GPR) data for aquifer characterization. By stitching together GPR tomograms from multiple adjacent crosshole planes, we are able to image, with a decimeter scale resolution, the dielectric permittivity and electrical conductivity of an alluvial aquifer along cross sections of 50 m length and 10 m depth. A logistic regression model is employed to predict the spatial distribution of lithological facies on the basis of the GPR results. Vertical profiles of porosity and hydraulic conductivity from direct-push, flowmeter and grain size data suggest that the GPR predicted facies classification is meaningful with regard to porosity and hydraulic conductivity, even though the distributions of individual facies show some overlap and the absolute hydraulic conductivities from the different methods (direct-push, flowmeter, grain size) differ up to approximately one order of magnitude. Comparison of the GPR predicted facies architecture with tracer test data suggests that the plume splitting observed in a tracer experiment was caused by a hydraulically low-conductive sand layer with a thickness of only a few decimeters. Because this sand layer is identified by GPR full-waveform inversion but not by conventional GPR ray-based inversion we conclude that the improvement in spatial resolution due to full-waveform inversion is crucial to detect small-scale aquifer structures that are highly relevant for solute transport.

  7. New high-resolution computed tomography data of the Taung partial cranium and endocast and their bearing on metopism and hominin brain evolution.

    Science.gov (United States)

    Holloway, Ralph L; Broadfield, Douglas C; Carlson, Kristian J

    2014-09-09

    Falk and colleagues [Falk D, Zollikofer CP, Morimoto N, Ponce de León MS (2012) Proc Natl Acad Sci U S A 109(22):8467-8470] hypothesized that selective pressures favored late persistence of a metopic suture and open anterior fontanelle early in hominin evolution, and they put an emphasis on the Taung Child (Australopithecus africanus) as evidence for the antiquity of these adaptive features. They suggested three mutually nonexclusive pressures: an "obstetric dilemma," high early postnatal brain growth rates, and neural reorganization in the frontal cortex. To test this hypothesis, we obtained the first high-resolution computed tomography (CT) data from the Taung hominin. These high-resolution image data and an examination of the hominin fossil record do not support the metopic and fontanelle features proposed by Falk and colleagues. Although a possible remnant of the metopic suture is observed in the nasion-glabella region of the Taung partial cranium (but not along the frontal crest), this character state is incongruent with the zipper model of metopic closure described by Falk and colleagues. Nor do chimpanzee and bonobo endocast data support the assertion that delayed metopic closure in Taung is necessary because of widening (reorganization) of the prefrontal or frontal cortex. These results call into question the adaptive value of delaying metopic closure, and particularly its antiquity in hominin evolution. Further data from hominoids and hominins are required to support the proposed adaptive arguments, particularly an obstetric dilemma placing constraints on neural and cranial development in Australopithecus.

  8. Detection and monitoring of early airway injury effects of half-mustard (2-chloroethylethylsulfide) exposure using high-resolution optical coherence tomography

    Science.gov (United States)

    Kreuter, Kelly A.; Mahon, Sari B.; Mukai, David S.; Su, Jianping; Jung, Woong-Gyu; Narula, Navneet; Guo, Shuguang; Wakida, Nicole; Raub, Chris; Berns, Michael W.; George, Steven C.; Chen, Zhongping; Brenner, Matthew

    2009-07-01

    Optical coherence tomography (OCT) is a noninvasive, high-resolution imaging technology capable of delivering real-time, near-histologic images of tissues. Mustard gas is a vesicant-blistering agent that can cause severe and lethal damage to airway and lungs. The ability to detect and assess airway injury in the clinical setting of mustard exposure is currently limited. The purpose of this study is to assess the ability to detect and monitor progression of half-mustard [2-chloroethylethylsulfide (CEES)] airway injuries with OCT techniques. A ventilated rabbit mustard exposure airway injury model is developed. A flexible fiber optic OCT probe is introduced into the distal trachea to image airway epithelium and mucosa in vivo. Progression of airway injury is observed over eight hours with OCT using a prototype time-domain superluminescent diode OCT system. OCT tracheal images from CEES exposed animals are compared to control rabbits for airway mucosal thickening and other changes. OCT detects the early occurrence and progression of dramatic changes in the experimental group after exposure to CEES. Histology and immunofluorescence staining confirms this finding. OCT has the potential to be a high resolution imaging modality capable of detecting, assessing, and monitoring treatment for airway injury following mustard vesicant agent exposures.

  9. Interlobate esker architecture and related hydrogeological features derived from a combination of high-resolution reflection seismics and refraction tomography, Virttaankangas, southwest Finland

    Science.gov (United States)

    Maries, Georgiana; Ahokangas, Elina; Mäkinen, Joni; Pasanen, Antti; Malehmir, Alireza

    2017-05-01

    A novel high-resolution (2-4 m source and receiver spacing) reflection and refraction seismic survey was carried out for aquifer characterization and to confirm the existing depositional model of the interlobate esker of Virttaankangas, which is part of the Säkylänharju-Virttaankangas glaciofluvial esker-chain complex in southwest Finland. The interlobate esker complex hosting the managed aquifer recharge (MAR) plant is the source of the entire water supply for the city of Turku and its surrounding municipalities. An accurate delineation of the aquifer is therefore critical for long-term MAR planning and sustainable use of the esker resources. Moreover, an additional target was to resolve the poorly known stratigraphy of the 70-100-m-thick glacial deposits overlying a zone of fractured bedrock. Bedrock surface as well as fracture zones were confirmed through combined reflection seismic and refraction tomography results and further validated against existing borehole information. The high-resolution seismic data proved successful in accurately delineating the esker cores and revealing complex stratigraphy from fan lobes to kettle holes, providing valuable information for potential new pumping wells. This study illustrates the potential of geophysical methods for fast and cost-effective esker studies, in particular the digital-based landstreamer and its combination with geophone-based wireless recorders, where the cover sediments are reasonably thick.

  10. High-resolution spiral computed tomography with multiplanar reformatting, 3D surface- and volume rendering: a non-destructive method to visualize ancient Egyptian mummification techniques.

    Science.gov (United States)

    Jansen, Roel J; Poulus, Martin; Taconis, Wijbren; Stoker, Jaap

    2002-01-01

    Ancient Egyptians used mummification techniques to prevent their deceased from decay. This study evaluates the potential of computed tomography (CT) in determining these techniques in a non-destructive way. Twenty-five mummies were studied by using high-resolution spiral CT, 1mm slice thickness for the head and 3mm slice thickness for the rest of the body. Images were reconstructed with 3D, multiplanar reformatting and volume rendering. In all cases the used mummification techniques could be reconstructed. The way the brain was removed, the presence of chemicals, like resin and natron, could be detected and the way the intestines were handled could be made visible. The use of CT is indispensable as a non-destructive method in the reconstruction of mummification techniques.

  11. Sex- and Age-Related Differences in Bone Microarchitecture in Men Relative to Women Assessed by High-Resolution Peripheral Quantitative Computed Tomography

    Directory of Open Access Journals (Sweden)

    Shreyasee Amin

    2012-01-01

    Full Text Available The trabecular and cortical compartments of bone each contributes to bone strength. Until recently, assessment of trabecular and cortical microstructure has required a bone biopsy. Now, trabecular and cortical microstructure of peripheral bone sites can be determined noninvasively using high-resolution peripheral quantitative computed tomography (HR-pQCT. Studies that have used HR-pQCT to evaluate cohorts of both men and women have provided novel insights into the changes in bone microarchitecture that occur with age between the sexes, which may help to explain the lower fracture incidence in older men relative to women. This review will highlight observations from these studies on both the sex- and age-related differences in trabecular and cortical microstructure that may underlie the differences in bone strength, and thereby fracture risk, between men and women.

  12. High-resolution three-dimensional imaging of red blood cells parasitized by Plasmodium falciparum and in situ hemozoin crystals using optical diffraction tomography

    Science.gov (United States)

    Kim, Kyoohyun; Yoon, HyeOk; Diez-Silva, Monica; Dao, Ming; Dasari, Ramachandra R.; Park, YongKeun

    2014-01-01

    We present high-resolution optical tomographic images of human red blood cells (RBC) parasitized by malaria-inducing Plasmodium falciparum (Pf)-RBCs. Three-dimensional (3-D) refractive index (RI) tomograms are reconstructed by recourse to a diffraction algorithm from multiple two-dimensional holograms with various angles of illumination. These 3-D RI tomograms of Pf-RBCs show cellular and subcellular structures of host RBCs and invaded parasites in fine detail. Full asexual intraerythrocytic stages of parasite maturation (ring to trophozoite to schizont stages) are then systematically investigated using optical diffraction tomography algorithms. These analyses provide quantitative information on the structural and chemical characteristics of individual host Pf-RBCs, parasitophorous vacuole, and cytoplasm. The in situ structural evolution and chemical characteristics of subcellular hemozoin crystals are also elucidated.

  13. Sarcoidose pulmonar: achados na tomografia computadorizada de alta resolução Pulmonary sarcoidosis: high-resolution computed tomography findings

    Directory of Open Access Journals (Sweden)

    Bruno Barcelos da Nóbrega

    2005-06-01

    Full Text Available A sarcoidose é uma doença sistêmica de causa indeterminada, caracterizada por granulomas não-caseosos. Embora possa afetar qualquer órgão, esta doença tem sua morbi-mortalidade relacionada principalmente ao acometimento pulmonar, presente em 80% a 90% dos pacientes. Este artigo ilustra as principais manifestações pulmonares da sarcoidose na tomografia computadorizada de alta resolução, incluindo as formas típicas e atípicas.Sarcoidosis is a systemic disease of unknown etiology, characterized by noncaseating granulomas. Although it may affect any organ, morbidity and mortality are most commonly related to pulmonary involvement, which is found in 80-90% of patients. This study illustrates the principal manifestations of sarcoidosis seen in high-resolution computed tomography scans, including typical as well as atypical forms.

  14. High-resolution computed tomography of the lungs in pediatric patients; Hochaufloesende Computertomographie der Lunge im Kindesalter

    Energy Technology Data Exchange (ETDEWEB)

    Reuter, M.; Oppermann, H.C.; Biederer, J.; Heller, M. [Klinik fuer Diagnostische Radiologie, Universitaetsklinikum Kiel (Germany); Ankermann, T. [Klinik fuer Allgemeine Paediatrie, Universitaetsklinikum Kiel (Germany)

    2002-06-01

    Since the introduction of the high-resolution technique more than ten years ago, HRCT has become an established modality for diagnosing diseases of the respiratory system. This is especially true for the diagnosis of lung diseases in adults. Experience in HRCT of the lungs is limited in pediatric patients. This review gives an overview of frequent and less frequent HRCT findings in pulmonary diseases in childhood. A purely reticular pattern is rarely observed in infants. Pulmonary diseases associated with overinflation are relatively frequent. Paired inspiratory-expiratory scans combine morphological analysis with functional information and have improved the diagnosis of air trapping, e.g. in post-infectious bronchiolitis obliterans or bronchopulmonary dysplasia. Especially in children the high radiation exposure is a problem. Even when applying a low-dose protocol the radiation dose of HRCT will still exceed the dose of a chest X-ray by 100 times. The indication for pediatric pulmonary HRCT is limited to selected cases and it should be decided in agreement with the pediatric radiologists and the pediatric pulmonologists. (orig.) [German] Seit Einfuehrung der hochaufloesenden Computertomographie (HRCT) vor gut 10 Jahren hat sich diese Untersuchungstechnik fuer die Diagnostik von Erkrankungen der Atemwege und des Lungenparenchyms etabliert. Dies gilt vor allem fuer Lungenerkrankungen im Erwachsenenalter. Demgegenueber bestehen vergleichsweise wenig Erfahrungen mit der HRCT in der paediatrischen Lungendiagnostik. In der vorliegenden Uebersichtsarbeit werden HRCT-Befunde bei haeufigen und seltener vorkommenden Lungenerkrankungen bei Kindern beschrieben. Ein rein retikulaeres Muster ist im Kindesalter selten. Demgegenueber werden mit einer pulmonalen Obstruktion (Air trapping) einhergehende Erkrankungen gehaeuft beobachtet. Paarige Inspirations-Exspirationsaufnahmen ergaenzen die rein strukturelle Analyse um eine funktionelle Komponente und haben sich bei obstruktiven

  15. Study on beam geometry and image reconstruction algorithm in fast neutron computerized tomography at NECTAR facility

    Energy Technology Data Exchange (ETDEWEB)

    Guo, J. [State Key Laboratory of Nuclear Physics and Technology and School of Physics, Peking University, 5 Yiheyuan Lu, Beijing 100871 (China); Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, Garching 80748 (Germany); Buecherl, T. [Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, Garching 80748 (Germany); Zou, Y., E-mail: zouyubin@pku.edu.cn [State Key Laboratory of Nuclear Physics and Technology and School of Physics, Peking University, 5 Yiheyuan Lu, Beijing 100871 (China); Guo, Z. [State Key Laboratory of Nuclear Physics and Technology and School of Physics, Peking University, 5 Yiheyuan Lu, Beijing 100871 (China)

    2011-09-21

    Investigations on the fast neutron beam geometry for the NECTAR facility are presented. The results of MCNP simulations and experimental measurements of the beam distributions at NECTAR are compared. Boltzmann functions are used to describe the beam profile in the detection plane assuming the area source to be set up of large number of single neutron point sources. An iterative algebraic reconstruction algorithm is developed, realized and verified by both simulated and measured projection data. The feasibility for improved reconstruction in fast neutron computerized tomography at the NECTAR facility is demonstrated.

  16. Karyotype, Pedigree and cone-beam computerized tomography analysis of a case of nonsyndromic pandental anomalies.

    Science.gov (United States)

    Dharmani, Umesh; Jadhav, Ganesh Ranganath; Kaur Dharmani, Charan Kamal; Rajput, Akhil; Mittal, Priya; Abraham, Sathish; Soni, Vinay

    2015-01-01

    This case report presented a karyotype and pedigree analysis of a case with unusual combination of dental anomalies: Generalized short roots, talon cusps, dens invagination, low alveolar bone heights, very prominent cusp of carabelli and protostylid on first permanent molars, taurodontism of second permanent molars, rotated, missing and impacted teeth. None of the anomalies alone are rare. However, until date, nonsyndromic pandental anomalies that are affecting entire dentition with detailed karyotype, pedigree and cone-beam computerized tomography analysis have not been reported. The occurrence of these anomalies is probably incidental as the conditions are etiologically unrelated.

  17. Detection of drugs and explosives using neutron computerized tomography and artificial intelligence techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, F.J.O. [Instituto de Engenharia Nuclear, Cidade Universitaria, Rio de Janeiro, CEP 21945-970, Caixa Postal 68550 (Brazil)], E-mail: fferreira@ien.gov.br; Crispim, V.R.; Silva, A.X. [DNC/Poli, PEN COPPE CT, UFRJ Universidade Federal do Rio de Janeiro, CEP 21941-972, Caixa Postal 68509, Rio de Janeiro (Brazil)

    2010-06-15

    In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.

  18. Detection of drugs and explosives using neutron computerized tomography and artificial intelligence techniques.

    Science.gov (United States)

    Ferreira, F J O; Crispim, V R; Silva, A X

    2010-06-01

    In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials. Copyright 2010 Elsevier Ltd. All rights reserved.

  19. Karyotype, Pedigree and cone-beam computerized tomography analysis of a case of nonsyndromic pandental anomalies

    Science.gov (United States)

    Dharmani, Umesh; Jadhav, Ganesh Ranganath; Kaur Dharmani, Charan Kamal; Rajput, Akhil; Mittal, Priya; Abraham, Sathish; Soni, Vinay

    2015-01-01

    This case report presented a karyotype and pedigree analysis of a case with unusual combination of dental anomalies: Generalized short roots, talon cusps, dens invagination, low alveolar bone heights, very prominent cusp of carabelli and protostylid on first permanent molars, taurodontism of second permanent molars, rotated, missing and impacted teeth. None of the anomalies alone are rare. However, until date, nonsyndromic pandental anomalies that are affecting entire dentition with detailed karyotype, pedigree and cone-beam computerized tomography analysis have not been reported. The occurrence of these anomalies is probably incidental as the conditions are etiologically unrelated. PMID:26283856

  20. The dental cavities of equine cheek teeth: three-dimensional reconstructions based on high resolution micro-computed tomography

    Directory of Open Access Journals (Sweden)

    Kopke Susan

    2012-09-01

    Full Text Available Abstract Background Recent studies reported on the very complex morphology of the pulp system in equine cheek teeth. The continuous production of secondary dentine leads to distinct age-related changes of the endodontic cavity. Detailed anatomical knowledge of the dental cavities in all ages is required to explain the aetiopathology of typical equine endodontic diseases. Furthermore, data on mandibular and maxillary pulp systems is in high demand to provide a basis for the development of endodontic therapies. However, until now examination of the pulp cavity has been based on either sectioned teeth or clinical computed tomography. More precise results were expected by using micro-computed tomography with a resolution of about 0.1 mm and three-dimensional reconstructions based on previous greyscale analyses and histological verification. The aim of the present study was to describe the physiological configurations of the pulp system within a wide spectrum of tooth ages. Results Maxillary teeth: All morphological constituents of the endodontic cavity were present in teeth between 4 and 16 years: Triadan 06s displayed six pulp horns and five root canals, Triadan 07-10s five pulp horns and four root canals and Triadan 11s seven pulp horns and four to six root canals. A common pulp chamber was most frequent in teeth ≤5 years, but was found even in a tooth of 9 years. A large variety of pulp configurations was observed within 2.5 and 16 years post eruption, but most commonly a separation into mesial and distal pulp compartments was seen. Maxillary cheek teeth showed up to four separate pulp compartments but the frequency of two, three and four pulp compartments was not related to tooth age (P > 0.05. In Triadan 06s, pulp horn 6 was always connected to pulp horns 1 and 3 and root canal I. In Triadan 11s, pulp horns 7 and 8 were present in variable constitutions. Mandibular teeth: A common pulp chamber was present in teeth up to 15 years, but most

  1. Preclinical evaluation and intraoperative human retinal imaging with a high-resolution microscope-integrated spectral domain optical coherence tomography device.

    Science.gov (United States)

    Hahn, Paul; Migacz, Justin; O'Donnell, Rachelle; Day, Shelley; Lee, Annie; Lin, Phoebe; Vann, Robin; Kuo, Anthony; Fekrat, Sharon; Mruthyunjaya, Prithvi; Postel, Eric A; Izatt, Joseph A; Toth, Cynthia A

    2013-01-01

    The authors have recently developed a high-resolution microscope-integrated spectral domain optical coherence tomography (MIOCT) device designed to enable OCT acquisition simultaneous with surgical maneuvers. The purpose of this report is to describe translation of this device from preclinical testing into human intraoperative imaging. Before human imaging, surgical conditions were fully simulated for extensive preclinical MIOCT evaluation in a custom model eye system. Microscope-integrated spectral domain OCT images were then acquired in normal human volunteers and during vitreoretinal surgery in patients who consented to participate in a prospective institutional review board-approved study. Microscope-integrated spectral domain OCT images were obtained before and at pauses in surgical maneuvers and were compared based on predetermined diagnostic criteria to images obtained with a high-resolution spectral domain research handheld OCT system (HHOCT; Bioptigen, Inc) at the same time point. Cohorts of five consecutive patients were imaged. Successful end points were predefined, including ≥80% correlation in identification of pathology between MIOCT and HHOCT in ≥80% of the patients. Microscope-integrated spectral domain OCT was favorably evaluated by study surgeons and scrub nurses, all of whom responded that they would consider participating in human intraoperative imaging trials. The preclinical evaluation identified significant improvements that were made before MIOCT use during human surgery. The MIOCT transition into clinical human research was smooth. Microscope-integrated spectral domain OCT imaging in normal human volunteers demonstrated high resolution comparable to tabletop scanners. In the operating room, after an initial learning curve, surgeons successfully acquired human macular MIOCT images before and after surgical maneuvers. Microscope-integrated spectral domain OCT imaging confirmed preoperative diagnoses, such as full-thickness macular hole

  2. Vectorial reconstruction of retinal blood flow in three dimensions measured with high resolution resonant Doppler Fourier domain optical coherence tomography.

    Science.gov (United States)

    Michaely, Roland; Bachmann, Adrian H; Villiger, Martin L; Blatter, Cédric; Lasser, Theo; Leitgeb, Rainer A

    2007-01-01

    Resonant Doppler Fourier domain optical coherence tomography (FDOCT) is a functional imaging tool for extracting tissue flow. The method is based on the effect of interference fringe blurring in spectrometer-based FDOCT, where the path difference between structure and reference changes during camera integration. If the reference path length is changed in resonance with the Doppler frequency of the sample flow, the signals of resting structures will be suppressed, whereas the signals of blood flow are enhanced. This allows for an easy extraction of vascularization structure. Conventional flow velocity analysis extracts only the axial flow component, which strongly depends on the orientation of the vessel with respect to the incident light. We introduce an algorithm to extract the vessel geometry within the 3-D data volume. The algorithm calculates the angular correction according to the local gradients of the vessel orientations. We apply the algorithm on a measured 3-D resonant Doppler dataset. For validation of the reproducibility, we compare two independently obtained 3-D flow maps of the same volunteer and region.

  3. Non-destructive quantification of cereal roots in soil using high-resolution X-ray tomography.

    Science.gov (United States)

    Flavel, Richard J; Guppy, Christopher N; Tighe, Matthew; Watt, Michelle; McNeill, Ann; Young, Iain M

    2012-04-01

    One key constraint to further understanding plant root development is the inability to observe root growth in situ due to the opaque nature of soil. Of the present non-destructive techniques, computed tomography (CT) is best able to capture the complexities of the edaphic environment. This study compared the accuracy and impact of X-ray CT measurement of in situ root systems with standard technology (soil core washing and WinRhizo analysis) in the context of treatments that differed in the vertical placement of phosphorus fertilizers within the soil profile. Although root lengths quantified using WinRhizo were 8% higher than that observed in the same plants using CT, measurements of root length by the two methodologies were highly correlated. Comparison of scanned and unscanned plants revealed no effect of repeated scanning on plant growth and CT was not able to detect any changes in roots between phosphorus treatments that was observed using WinRhizo. Overall, the CT technique was found to be fast, safe, and able to detect roots at high spatial resolutions. The potential drawbacks of CT relate to the software to digitally segment roots from soil and air, which will improve significantly as automated segmentation algorithms are developed. The combination of very fast scans and automated segmentation will allow CT methodology to realize its potential as a high-throughput technique for the quantification of roots in soils.

  4. 3D noninvasive, high-resolution imaging using a photoacoustic tomography (PAT) system and rapid wavelength-cycling lasers

    Science.gov (United States)

    Sampathkumar, Ashwin; Gross, Daniel; Klosner, Marc; Chan, Gary; Wu, Chunbai; Heller, Donald F.

    2015-05-01

    Globally, cancer is a major health issue as advances in modern medicine continue to extend the human life span. Breast cancer ranks second as a cause of cancer death in women in the United States. Photoacoustic (PA) imaging (PAI) provides high molecular contrast at greater depths in tissue without the use of ionizing radiation. In this work, we describe the development of a PA tomography (PAT) system and a rapid wavelength-cycling Alexandrite laser designed for clinical PAI applications. The laser produces 450 mJ/pulse at 25 Hz to illuminate the entire breast, which eliminates the need to scan the laser source. Wavelength cycling provides a pulse sequence in which the output wavelength repeatedly alternates between 755 nm and 797 nm rapidly within milliseconds. We present imaging results of breast phantoms with inclusions of different sizes at varying depths, obtained with this laser source, a 5-MHz 128-element transducer and a 128-channel Verasonics system. Results include PA images and 3D reconstruction of the breast phantom at 755 and 797 nm, delineating the inclusions that mimic tumors in the breast.

  5. High Resolution Vp and Vp/Vs Local Earthquake Tomography of the Val d'Agri Region (Southern Apennines, Italy).

    Science.gov (United States)

    Improta, L.; Bagh, S.; De Gori, P.; Pastori, M.; Piccinini, D.; Valoroso, L.; Anselmi, M.; Buttinelli, M.; Chiarabba, C.

    2015-12-01

    The Val d'Agri (VA) Quaternary basin in the southern Apennines extensional belt hosts the largest oilfield in onshore Europe and normal-fault systems with high (up to M7) seismogenic potential. Frequent small-magnitude swarms related to both active crustal extension and anthropogenic activity have occurred in the region. Causal factors for induced seismicity are a water impoundment with severe seasonal oscillations and a high-rate wastewater injection well. We analyzed around 1200 earthquakes (MLENI petroleum company. We used local earthquake tomography to investigate static and transient features of the crustal velocity structure and to accurately locate earthquakes. Vp and Vp/Vs models are parameterized by a 3x3x2 km spacing and well resolved down to about 12 km depth. The complex Vp model illuminates broad antiformal structures corresponding to wide ramp-anticlines involving Mesozoic carbonates of the Apulia hydrocarbon reservoir, and NW-SE trending low Vp regions related to thrust-sheet-top clastic basins. The VA basin corresponds to shallow low-Vp region. Focal mechanisms show normal faulting kinematics with minor strike slip solutions in agreement with the local extensional regime. Earthquake locations and focal solutions depict shallow (< 5 km depth) E-dipping extensional structures beneath the artificial lake located in the southern sector of the basin, and along the western margin of the VA. A few swarms define relatively deep transfer structures accommodating the differential extension between main normal faults. The spatio-temporal distribution of around 220 events correlates with wastewater disposal activity, illuminating a NE-dipping fault between 2-5 km depth in the carbonate reservoir. The fault measures 5 km along dip and corresponds to a pre-existing thrust fault favorably oriented with respect to the local extensional field.

  6. Serial High-Resolution Computed Tomography Imaging in Patients with Wegener Granulomatosis: Differentiation Between Active Inflammatory and Chronic Fibrotic Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lohrmann, C.; Uhl, M.; Schaefer, O.; Ghanem, N.; Kotter, E.; Langer, M. [Univ. Hospital of Freiburg (Germany). Dept. of Radiology

    2005-08-01

    PURPOSE: To evaluate pulmonary pathologies in Wegener granulomatosis with sequential computed tomography (CT) in order to differentiate active inflammatory lesions from chronic fibrotic lesions. MATERIAL AND METHODS: Serial CT findings in 38 patients with Wegener granulomatosis were retrospectively analyzed (mean follow-up period, 21 months). The presence, extension, and distribution of the following findings were evaluated with CT: parenchymal nodules, masses, ground-glass attenuation, airspace consolidation, bronchial wall-thickening, bronchiectasis, linear areas of attenuation, pleural irregularities, pleural effusions, hilar and mediastinal lymphadenopathy. RESULTS: Observed in 92% of patients, nodules were the most common CT pathology. Areas of ground-glass attenuation, consolidation, masses of linear attenuation, and tracheal/bronchial wall-thickening were detected in 24%, 26%, 32%, 39%, and 68% of patients. At follow-up, the clearance of lesions was most consistent for areas of ground-glass attenuation (89%), masses (87%), and cavitated nodules (85%). In the follow-up scan, 58% of all nodules, 47% of pulmonary consolidations, and 66% of bronchial wall-thickening were completely resolved. Areas of bronchiectasis and septal/non-septal lines remained stable in 70% and 71% of patients. CONCLUSION: The majority of the lesions decreased or resolved completely with or without areas of linear attenuation. Ground-glass attenuation, cavitated nodules and masses appear to represent active inflammatory lesions. In most probability, areas of bronchiectasis and septal/non-septal lines more often represent chronic fibrotic changes rather than active inflammatory changes. In combination with clinical evaluation and bronchoscopy, CT assists in the assessment of disease activity.

  7. Heavy ion and proton beams in high resolution imaging of a fungi spore specimen using STIM tomography

    Science.gov (United States)

    Formenti, P.; Breese, M. B. H.; Connell, S. H.; Doyle, B. P.; Drummond, M. L.; Machi, I. Z.; Maclear, R. D.; Schaaff, P.; Sellschop, J. P. F.; Bench, G.; Sideras-Haddad, E.; Antolak, A.; Morse, D.

    1997-07-01

    Scanning transmission ion microscopy (STIM) tomography as a 3-D imaging technique has been shown to have a range of applications. The energy of the transmitted ion is detected with nearly 100% efficiency as a function of position in the transverse plane. The parameters relating to transmitted ion energy loss in the sample are imaged with statistics given by the energy loss process rather than Poisson counting statistics. This enables very fast collection of a set of relatively noise-free 2-D images. Each image is collected after a small rotation of the sample, and a complete 3-D representation of the sample may be tomographically reconstructed. The small beam currents necessary mean that the technique is non-destructive. One of the fields where these non-destructive 3-D density structure maps are particularly useful is in the analysis of biological tissue. The variation of energy loss with projectile atomic number may be exploited to tune the energy loss contrast to the size and density of the sample (heavy ion STIM). This work develops this point, and applies it to the imaging of the microscopic structure of a 90 μm diameter mycorrhiza fungi spore. This specimen has been imaged non-destructively in 3-D using both a 36 MeV 12C beam and a 2.2 MeV proton beam, both with a spatial resolution of about 1 μm. The gain in contrast in the carbon median energy loss maps was dramatic as expected. The corresponding improvement in the tomogram was found to be visible but less dramatic. The tomographic sections as well as the median energy loss maps of the vesicular-arbuscular mycorrhiza fungi spore clearly show the internal structure. Wall morphology data has relevance to germination behaviour of the spores.

  8. Cerebral glucose utilization measured with high resolution positron emission tomography in epileptic Finnish Spitz dogs and healthy dogs.

    Science.gov (United States)

    Viitmaa, Ranno; Haaparanta-Solin, Merja; Snellman, Marjatta; Cizinauskas, Sigitas; Orro, Toomas; Kuusela, Erja; Johansson, Jarkko; Viljanen, Tapio; Jokinen, Tarja S; Bergamasco, Luciana; Metsähonkala, Liisa

    2014-01-01

    In human epileptic patients, changes in cerebral glucose utilization can be detected 2-deoxy-2-[(18) F] fluoro-D-glucose positron emission tomography (FDG-PET). The purpose of this prospective study was to determine whether epileptic dogs might show similar findings. Eleven Finnish Spitz dogs with focal idiopathic epilepsy and six healthy dogs were included. Dogs were examined using electroencephalography (EEG) and FDG-PET, with epileptic dogs being evaluated during the interictal period. Visual and semi-quantitative assessment methods of FDG-PET were compared and contrasted with EEG findings. Three independent observers, unaware of dog clinical status, detected FDG-PET uptake abnormalities in 9/11 epileptic (82%), and 4/8 healthy dogs (50%). Occipital cortex findings were significantly associated with epileptic status (P = 0.013). Epileptic dogs had significantly lower standardized uptake values (SUVs) in numerous cortical regions, the cerebellum, and the hippocampus compared to the control dogs. The lowest SUVs were found in the occipital lobe. White matter normalized and left-right asymmetry index values for all pairs of homologous regions did not differ between groups. Visual evaluation of the EEGs was less sensitive (36%) than FDG-PET. Both diagnostic tests were consensual and specific (100%) for occipital findings, but EEG had a lower sensitivity for detecting lateralized foci than FDG-PET. Findings supported the use of FDG-PET as a diagnostic test for dogs with suspected idiopathic epilepsy. Visual and semiquantitative analyses of FDG-PET scans provided complementary information. Findings also supported the theory that epileptogenesis may occur in multiple brain regions in Finnish Spitz dogs with idiopathic epilepsy. © 2014 American College of Veterinary Radiology.

  9. The accuracy and diagnostic yield of computerized tomography guided stereotactic biopsy in brain lesions.

    Science.gov (United States)

    Calişaneller, Tarkan; Ozdemir, Ozgür; Ozger, Ozkan; Ozen, Ozlem; Kiyici, Halil; Caner, Hakan; Altinörs, Nur

    2008-01-01

    Radiological imaging techniques provide early detection of neurological diseases but they do not always provide an adequate and reliable diagnosis. With the help of stereotactic biopsy techniques, it is possible to access brain lesions safely and with high precision. We described the surgical method used in our clinic and discussed our results with the help of the current literature. Ninety-four patients underwent computerized tomography-guided stereotactic brain biopsy in our clinic. Anatomical locations, diagnostic yield and accuracy of the procedure, morbidity and mortality rates were analyzed. A total of 100 stereotactic surgery procedures were performed on 94 patients. The localizations of the lesions were 13.83% frontal, 21.27% temporal, 27.66% parietal, 4.25% occipital, 4.25% multiple, 27.66% deep seated and 1.06% suprasellar. The histopathological diagnoses were 61.71% neuro-epithelial tumors, 8.51% metastases and 10.64% infectious lesions. Diagnostic yield was 86.16% and the accuracy was 90% in our series. Computerized tomography-guided stereotactic brain biopsy is a reliable and safe method. Main diagnostic problems in SBB are tissue heterogeneity, insufficient material and sampling error. These problems can be minimized by careful correlation of clinical, radiological and histopathological findings by an experienced team and by using modern technologies.

  10. Robust phase retrieval for high resolution edge illumination x-ray phase-contrast computed tomography in non-ideal environments

    Science.gov (United States)

    Zamir, Anna; Endrizzi, Marco; Hagen, Charlotte K.; Vittoria, Fabio A.; Urbani, Luca; De Coppi, Paolo; Olivo, Alessandro

    2016-01-01

    Edge illumination x-ray phase contrast tomography is a recently developed imaging technique which enables three-dimensional visualisation of low-absorbing materials. Dedicated phase retrieval algorithms can provide separate computed tomography (CT) maps of sample absorption, refraction and scattering properties. In this paper we propose a novel “modified local retrieval” method which is capable of accurately retrieving sample properties in a range of realistic, non-ideal imaging environments. These include system misalignment, defects in the used optical elements and system geometry variations over time due to vibrations or temperature fluctuations. System instabilities were analysed, modelled and incorporated into a simulation study. As a result, an additional modification was introduced to the retrieval procedure to account for changes in the imaging system over time, as well as local variations over the field of view. The performance of the proposed method was evaluated in comparison to a previously used “global retrieval” method by applying both approaches to experimental CT data of a rat’s heart acquired in a non-ideal environment. The use of the proposed method resulted in the removal of major artefacts, leading to a significant improvement in image quality. This method will therefore enable acquiring high-resolution, reliable CT data of large samples in realistic settings. PMID:27502296

  11. Pneumocystis carinii pneumonia in acquired immunodeficiency syndrome - correlation of high-resolution computed tomography and anatomopathology; Pneumocistose na sindrome da imunodeficiencia adquirida: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson; Moreira, Luiza Beatriz [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@zipmail.com.br; Capone, Domenico [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Patologia; Pereira, Cyntia Inez Guedes Soares

    2001-12-01

    We present the main findings observed on the high-resolution computed tomography examinations of 15 patients with acquired immunodeficiency syndrome and Pneumocystis carinii pneumonia. The high-resolution computed tomography and autopsy findings of 5 patients were also compared. The most frequently observed high-resolution computed tomography patterns were ground-glass attenuation, consolidation areas, crazy-paving pattern and cysts. Nodules and intralobular reticulation were less frequently observed. Ground-glass attenuation and consolidation areas corresponded to alveolar filling with inflammatory exudate. Thickening of the interlobular septa was due to cell infiltration and edema. One patient presented interlobular reticulation, and the pathology study revealed alveolar septa thickening due to cell infiltration and fibrosis. Nodules observed in one of the patients corresponded to a patchy intra alveolar accumulation of microorganisms and inflammatory cells forming a 'granulomatous' pattern. (author)

  12. Density evaluation by computerized tomography in plain soils over different manipulation systems; Avaliacao da densidade pelo metodo da tomografia computadorizada de um planossolo sob diferentes sistemas de manejo

    Energy Technology Data Exchange (ETDEWEB)

    Pedrotti, Alceu [Lavras Univ., MG (Brazil). Dept. de Ciencia do Solo; Pauletto, Eloy Antonio [Pelotas Univ., RS (Brazil). Dept. de Solos; Crestana, Silvio [Empresa Brasileira de Pesquisa Agropecuaria (EMBRAPA), Sao Carlos, SP (Brazil). Centro Nacional de Pesquisa e Desenvolvimento de Instrumentacao Agropecuaria (CNPDIA)

    1996-08-01

    The objective of this paper is the evaluation of a plain soil density in different culture systems determined by X ray computerized tomography.It was observed a larger variation in densities in soils profiles analysed. The identification of layers is better utilising computerized tomography than others technic 1 fig.

  13. Active disease and residual damage in treated Wegener's granulomatosis: an observational study using pulmonary high-resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Komocsi, Andras [Poliklinik fuer Rheumatologie, Universitaet Luebeck, Ratzeburger Allee 160, 23538 Luebeck (Germany); Reuter, Michael; Heller, Martin [Klinik fuer Diagnostische Radiologische, Universitaet Kiel, Arnold-Heller-Strasse 7, 24105 Kiel (Germany); Murakoezi, Henriette; Gross, Wolfgang L.; Schnabel, Armin [Poliklinik fuer Rheumatologie, Universitaet Luebeck, Ratzeburger Allee 160, 23538 Luebeck (Germany); Rheumaklinik Bad Bramstedt, Ratzeburger Allee 160, 23538 Luebeck (Germany)

    2003-01-01

    The purpose of this study was to determine to what extent high-resolution computed tomography (HRCT) of the lungs can distinguish active inflammatory disease from inactive cicatricial disease in patients treated for Wegener's granulomatosis (WG). Twenty-eight WG patients with active pulmonary disease underwent a first HRCT examination immediately before standard immunosuppressive treatment and a second examination after clinical remission had been achieved. Lesions remaining after treatment were categorized as residual damage and were compared with findings during active disease to see by what features active and cicatricial disease can be distinguished. During active disease 17 patients had nodules/masses, 12 had ground-glass opacities, 6 had septal lines and 6 had non-septal lines. After treatment, ground-glass opacities had resolved completely. Nodules/masses had resolved in 8 patients and had diminished in 7 patients. Residual nodules were distinguished from nodules/masses in active disease by lack of cavitation and a diameter of mostly <15 mm. In one-third of patients lines resolved, but in 8 instances new lines evolved during immunosuppression. During a follow-up period of a median 26.5 months (range 20.0-33.8), patients with residual nodules or lines had no more relapses than patients with completely cleared lungs. Treated pulmonary WG leaves substantial residual damage. High-resolution CT does assist in the distinction between active and inactive lesions. Ground-glass opacities, cavitating nodules/masses and masses measuring more than 3 cm represent active disease ordinarily. Non-cavitary small nodules and septal or non-septal lines can be either active or cicatricial lesions. The nature of these lesions needs to be clarified by longitudinal observation. (orig.)

  14. A multidisciplinary approach to landslide structure characterization: integration of seismic tomography survey and high resolution LiDar data with the Sloping Local Base Level method.

    Science.gov (United States)

    Travelletti, Julien; Samyn, Kevin; Malet, Jean-Philippe; Grandjean, Gilles; Jaboyedoff, Michel

    2010-05-01

    A challenge to progress in the understanding of landslides is to precisely define their 3D geometry and structure as an input for volume estimation and further hydro-mechanical modelling. The objective of this work is to present a multidisciplinary approach to the geometrical modelling of the La Valette landslide by integrating seismic tomography survey (P and S wave) and high resolution LiDar data with the Sloping Local Base Level (SLBL) method. The La Valette landslide, triggered in March 1982, is one of the most important slope instability in the South French Alps. Its dimensions are 1380 m length and 290 m width, and the total volume is estimated at 3.5 106 m3. Since 2002, an important activity of the upper part of the landslide is observed, and consisted mainly in the retrogression of the crown through the opening of an important fracture over several meters and rotational slumps. The failed mass is currently loading the upper part of the mudslide and is a potential threat for the 170 residential communities. A seismic tomography survey combined to airborne and terrestrial LiDar data analysis have been carried out to identify the geological structures and discontinuities and characterize the stability of the failing mass. Seismic tomography allows direct and non-intrusive measurements of P and S waves velocities which are key parameters for the analysis of the mechanical properties of reworked and highly fissured masses. 4 seismic lines have been performed (3 of them in the direction of the slope and the other perpendicular). The 2 longest devices are composed of 24 geophones spaced by 5 meters and have a sufficient investigation depth for a large scale characterization of the landslide's structure with depth. The 2 shortest devices, composed of 24 geophones spaced by 2 meters bring information about the fracturing degree between the moving material of the landslide and the competent rock. 100gr of pentrite for each shot were used as seismic sources. The

  15. Accurately Diagnosing Uric Acid Stones from Conventional Computerized Tomography Imaging: Development and Preliminary Assessment of a Pixel Mapping Software.

    Science.gov (United States)

    Ganesan, Vishnu; De, Shubha; Shkumat, Nicholas; Marchini, Giovanni; Monga, Manoj

    2018-02-01

    Preoperative determination of uric acid stones from computerized tomography imaging would be of tremendous clinical use. We sought to design a software algorithm that could apply data from noncontrast computerized tomography to predict the presence of uric acid stones. Patients with pure uric acid and calcium oxalate stones were identified from our stone registry. Only stones greater than 4 mm which were clearly traceable from initial computerized tomography to final composition were included in analysis. A semiautomated computer algorithm was used to process image data. Average and maximum HU, eccentricity (deviation from a circle) and kurtosis (peakedness vs flatness) were automatically generated. These parameters were examined in several mathematical models to predict the presence of uric acid stones. A total of 100 patients, of whom 52 had calcium oxalate and 48 had uric acid stones, were included in the final analysis. Uric acid stones were significantly larger (12.2 vs 9.0 mm, p = 0.03) but calcium oxalate stones had higher mean attenuation (457 vs 315 HU, p = 0.001) and maximum attenuation (918 vs 553 HU, p uric acid stones. A combination of stone size, attenuation intensity and attenuation pattern from conventional computerized tomography can distinguish uric acid stones from calcium oxalate stones with high sensitivity and specificity. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: a systematic review of the literature.

    NARCIS (Netherlands)

    Vos, W. De; Casselman, J.W.; Swennen, G.R.

    2009-01-01

    This study reviewed the literature on cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial (OMF) region. A PUBMED search (National Library of Medicine, NCBI; revised 1 December 2007) from 1998 to December 2007 was conducted. This search revealed 375 papers, which were

  17. A dataset describing brooding in three species of South African brittle stars, comprising seven high-resolution, micro X-ray computed tomography scans.

    Science.gov (United States)

    Landschoff, Jannes; Du Plessis, Anton; Griffiths, Charles L

    2015-01-01

    Brooding brittle stars have a special mode of reproduction whereby they retain their eggs and juveniles inside respiratory body sacs called bursae. In the past, studying this phenomenon required disturbance of the sample by dissecting the adult. This caused irreversible damage and made the sample unsuitable for future studies. Micro X-ray computed tomography (μCT) is a promising technique, not only to visualise juveniles inside the bursae, but also to keep the sample intact and make the dataset of the scan available for future reference. Seven μCT scans of five freshly fixed (70 % ethanol) individuals, representing three differently sized brittle star species, provided adequate image quality to determine the numbers, sizes and postures of internally brooded young, as well as anatomy and morphology of adults. No staining agents were necessary to achieve high-resolution, high-contrast images, which permitted visualisations of both calcified and soft tissue. The raw data (projection and reconstruction images) are publicly available for download from GigaDB. Brittle stars of all sizes are suitable candidates for μCT imaging. This explicitly adds a new technique to the suite of tools available for studying the development of internally brooded young. The purpose of applying the technique was to visualise juveniles inside the adult, but because of the universally good quality of the dataset, the images can also be used for anatomical or comparative morphology-related studies of adult structures.

  18. Use of high-resolution X-ray computed tomography and 3D image analysis to quantify mineral dissemination and pore space in oxide copper ore particles

    Science.gov (United States)

    Yang, Bao-hua; Wu, Ai-xiang; Narsilio, Guillermo A.; Miao, Xiu-xiu; Wu, Shu-yue

    2017-09-01

    Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle, a cylindrical copper oxide ore sample (ϕ4.6 mm × 5.6 mm) was scanned using high-resolution X-ray computed tomography (HRXCT), a nondestructive imaging technology, at a spatial resolution of 4.85 μm. Combined with three-dimensional (3D) image analysis techniques, the main mineral phases and pore space were segmented and the volume fraction of each phase was calculated. In addition, the mass fraction of each mineral phase was estimated and the result was validated with that obtained using traditional techniques. Furthermore, the pore phase features, including the pore size distribution, pore surface area, pore fractal dimension, pore centerline, and the pore connectivity, were investigated quantitatively. The pore space analysis results indicate that the pore size distribution closely fits a log-normal distribution and that the pore space morphology is complicated, with a large surface area and low connectivity. This study demonstrates that the combination of HRXCT and 3D image analysis is an effective tool for acquiring 3D mineralogical and pore structural data.

  19. Effects of pure and hybrid iterative reconstruction algorithms on high-resolution computed tomography in the evaluation of interstitial lung disease.

    Science.gov (United States)

    Katsura, Masaki; Sato, Jiro; Akahane, Masaaki; Mise, Yoko; Sumida, Kaoru; Abe, Osamu

    2017-08-01

    To compare image quality characteristics of high-resolution computed tomography (HRCT) in the evaluation of interstitial lung disease using three different reconstruction methods: model-based iterative reconstruction (MBIR), adaptive statistical iterative reconstruction (ASIR), and filtered back projection (FBP). Eighty-nine consecutive patients with interstitial lung disease underwent standard-of-care chest CT with 64-row multi-detector CT. HRCT images were reconstructed in 0.625-mm contiguous axial slices using FBP, ASIR, and MBIR. Two radiologists independently assessed the images in a blinded manner for subjective image noise, streak artifacts, and visualization of normal and pathologic structures. Objective image noise was measured in the lung parenchyma. Spatial resolution was assessed by measuring the modulation transfer function (MTF). MBIR offered significantly lower objective image noise (22.24±4.53, PASIR (39.76±7.41) and FBP (51.91±9.71). MTF (spatial resolution) was increased using MBIR compared with ASIR and FBP. MBIR showed improvements in visualization of normal and pathologic structures over ASIR and FBP, while ASIR was rated quite similarly to FBP. MBIR significantly improved subjective image noise (PASIR and FBP. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Interstitial pulmonary alterations in visceral leishmaniasis: evaluation with high-resolution computed tomography; Alteracoes pulmonares intersticiais na leishmaniose visceral: avaliacao pela tomografia computadorizada de alta resolucao

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Norma Selma Santos; Cerri, Giovanni Guido [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Dept. de Radiologia

    1999-08-01

    Visceral leishmaniasis, also called kala-azar, is a disease caused by a protozoan, the Leishmania donovani chagasi, that comprises reticuloendothelial system with involvement of the liver, spleen and bone marrow. It is endemic in some areas of northeastern Brazil and other countries of Latin America and Africa. The pathogenesis is related to the immunologic system of patients that present with the inability to activate the phagocytosis of the macrophages. As occurs in the liver and kidneys, the lungs are also involved with interstitial abnormalities caused by Leishmania that are not dependent upon the presence of the parasite. The histopathologic changes described are the involvement of inter alveolar septal in three different phases, irregularly and diffusely throughout the whole pulmonary parenchyma. This work analyzed high-resolution computed tomography (HRCT) of the thorax in 17 patients with visceral leishmaniasis in order to detect and characterize the abnormalities described in the anatomo pathologic findings reported in the literature. The HRCT is being used to evaluate chronic interstitial lung disease in a good correlation with histologic findings. The most common findings detected by HRCT were the reticular opacities that include peribronchovascular interstitial thickening and interlobular septal thickening an ground-glass opacity. The HRCT suggests that similar changes to that found in alveolar structures may occur in the secondary pulmonary lobule and that the involvement in the parenchymal interstitium represents the findings reported by pathological studies in visceral leishmaniasis. (author)

  1. Lean mass and fat mass have differing associations with bone microarchitecture assessed by high resolution peripheral quantitative computed tomography in men and women from the Hertfordshire Cohort Study

    Science.gov (United States)

    Edwards, Mark H; Ward, Kate A; Ntani, Georgia; Parsons, Camille; Thompson, Jennifer; Sayer, Avan A; Dennison, Elaine M; Cooper, Cyrus

    2015-01-01

    Understanding the effects of muscle and fat on bone is increasingly important in the optimisation of bone health. We explored relationships between bone microarchitecture and body composition in older men and women from the Hertfordshire Cohort Study. 175 men and 167 women aged 72-81 years were studied. High resolution peripheral quantitative computed tomography (HRpQCT) images (voxel size 82μm) were acquired from the non-dominant distal radius and tibia with a Scanco XtremeCT scanner. Standard morphological analysis was performed for assessment of macrostructure, densitometry, cortical porosity and trabecular microarchitecture. Body composition was assessed using dual energy x-ray absorptiometry (DXA) (Lunar Prodigy Advanced). Lean mass index (LMI) was calculated as lean mass divided by height squared and fat mass index (FMI) as fat mass divided by height squared. The mean (standard deviation) age in men and women was 76 (3) years. In univariate analyses, tibial cortical area (prelationships between cortical area and thickness were only maintained with LMI [tibial cortical area, β(95% confidence interval (CI)): men 6.99 (3.97,10.01), women 3.59 (1.81,5.38)] whereas trabecular number and density were associated with FMI. Interactions by sex were found, including for the relationships of LMI with cortical area and FMI with trabecular area in both the radius and tibia (prelationships with bone microarchitecture. Further studies are required to confirm the direction of causality and explore the mechanisms underlying these tissue-specific associations. PMID:26187195

  2. High-resolution computed tomography to differentiate chronic diffuse interstitial lung diseases with predominant ground-glass pattern using logical analysis of data

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Sophie Grivaud; Brauner, Michel W.; Rety, Frederique [Universite Paris 13, Assistance Publique-Hopitaux de Paris, Hopital Avicenne, UPRES EA 2363, Department of Radiology, Bobigny (France); Kronek, Louis-Philippe; Brauner, Nadia [Universite Joseph Fourier, Laboratoire G-SCOP, Grenoble (France); Valeyre, Dominique; Nunes, Hilario [Universite Paris 13, Assistance Publique-Hopitaux de Paris, Hopital Avicenne, UPRES EA 2363, Department of Pneumology, Bobigny (France); Brillet, Pierre-Yves [Universite Paris 13, Assistance Publique-Hopitaux de Paris, Hopital Avicenne, UPRES EA 2363, Department of Radiology, Bobigny (France); Hopital Avicenne, Service de Radiologie, Bobigny Cedex (France)

    2010-06-15

    We evaluated the performance of high-resolution computed tomography (HRCT) to differentiate chronic diffuse interstitial lung diseases (CDILD) with predominant ground-glass pattern by using logical analysis of data (LAD). A total of 162 patients were classified into seven categories: sarcoidosis (n = 38), connective tissue disease (n = 32), hypersensitivity pneumonitis (n = 18), drug-induced lung disease (n = 15), alveolar proteinosis (n = 12), idiopathic non-specific interstitial pneumonia (n = 10) and miscellaneous (n = 37). First, 40 CT attributes were investigated by the LAD to build up patterns characterising a category. From the association of patterns, LAD determined models specific to each CDILD. Second, data were recomputed by adding eight clinical attributes to the analysis. The 20 x 5 cross-folding method was used for validation. Models could be individualised for sarcoidosis, hypersensitivity pneumonitis, connective tissue disease and alveolar proteinosis. An additional model was individualised for drug-induced lung disease by adding clinical data. No model was demonstrated for idiopathic non-specific interstitial pneumonia and the miscellaneous category. The results showed that HRCT had a good sensitivity ({>=}64%) and specificity ({>=}78%) and a high negative predictive value ({>=}93%) for diseases with a model. Higher sensitivity ({>=}78%) and specificity ({>=}89%) were achieved by adding clinical data. The diagnostic performance of HRCT is high and can be increased by adding clinical data. (orig.)

  3. Lean mass and fat mass have differing associations with bone microarchitecture assessed by high resolution peripheral quantitative computed tomography in men and women from the Hertfordshire Cohort Study.

    Science.gov (United States)

    Edwards, Mark H; Ward, Kate A; Ntani, Georgia; Parsons, Camille; Thompson, Jennifer; Sayer, Avan A; Dennison, Elaine M; Cooper, Cyrus

    2015-12-01

    Understanding the effects of muscle and fat on bone is increasingly important in the optimisation of bone health. We explored relationships between bone microarchitecture and body composition in older men and women from the Hertfordshire Cohort Study. 175 men and 167 women aged 72-81 years were studied. High resolution peripheral quantitative computed tomography (HRpQCT) images (voxel size 82 μm) were acquired from the non-dominant distal radius and tibia with a Scanco XtremeCT scanner. Standard morphological analysis was performed for assessment of macrostructure, densitometry, cortical porosity and trabecular microarchitecture. Body composition was assessed using dual energy X-ray absorptiometry (DXA) (Lunar Prodigy Advanced). Lean mass index (LMI) was calculated as lean mass divided by height squared and fat mass index (FMI) as fat mass divided by height squared. The mean (standard deviation) age in men and women was 76 (3) years. In univariate analyses, tibial cortical area (pbone microarchitecture. Further studies are required to confirm the direction of causality and explore the mechanisms underlying these tissue-specific associations. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Large Field, High Resolution Full Field Optical Coherence Tomography: A Pre-clinical study of human breast tissue and cancer assessment

    CERN Document Server

    Assayag, Osnath; Sigal-Zafrani, Brigitte; Riben, Michael; Harms, Fabrice; Burcheri, Adriano; de Poly, Bertrand Le Conte; Boccara, Claude

    2012-01-01

    We present a benchmark pilot study in which high-resolution Full-Field Optical Coherence Tomography (FF-OCT) is used to image human breast tissue and is evaluated to assess its ability to aid the pathologist's management of intra-operative diagnoses. Our aim included evaluating the safety of FF-OCT on human tissue and determining the concordance between the images obtained with routinely prepared histopathological material. The compact device used for this study provides a 2 {\\mu}m-lateral and a 1 {\\mu}m-axial resolution, and is able to scan a 1.5cm^2 specimen in about 7 minutes. 75 breast specimens obtained from 22 patients have been imaged. Because the contrast in the images is generated by endogenous tissue components, no biological, contrast agents or specimen preparation is required. We characterized the major architectural features and tissue structures of benign breast tissue, including adipocytes, fibrous stroma, lobules and ducts. We subsequently characterized features resulting from their pathologic...

  5. Surfactant protein C gene (SFTPC) mutation-associated lung disease: high-resolution computed tomography (HRCT) findings and its relation to histological analysis.

    Science.gov (United States)

    Mechri, M; Epaud, R; Emond, S; Coulomb, A; Jaubert, F; Tarrant, A; Feldmann, D; Flamein, F; Clement, A; de Blic, J; Taam, R Abou; Brunelle, F; le Pointe, H Ducou

    2010-10-01

    Determine high-resolution tomography (HRCT) scan characteristics in children with SFTPC mutation and correlate them to histological findings. This retrospective multicenter study included 15 children (7 females and 8 males) with SFTPC mutations. HRCT scans have been performed in all the children and lung biopsies in 8 children. From all signs assessed on initial HRCT scans, ground-glass opacities (n =14, 93%) and lung cysts (n = 6, 40%) were predominant. Interlobular septal thickening (n = 1, 7%), air space consolidation (n = 1, 7%), paraseptal emphysema (n = 2, 13%), and pulmonary nodules (n = 1, 7%) were also found. Histological analysis revealed accumulation of macrophages in the alveolar lumen, type II pneumocyte hyperplasia, and alveolar septal thickening. Dilatation of the respiratory bronchiole and alveolar duct associated with muscular hyperplasia were also described. Interestingly, lung cysts on HRCT scans were associated with dilatation of terminal bronchioli and alveolar duct in lung biopsies. In children with SFTPC mutations, HRCT scan finding was highly correlated to the histological findings and, as such, represent a useful tool to identify patients that may require SFTPC gene sequencing. © 2010 Wiley-Liss, Inc.

  6. Resolution, sensitivity, and in vivo application of high-resolution computed tomography for titanium-coated polymethyl methacrylate (PMMA) dental implants.

    Science.gov (United States)

    Cuijpers, Vincent M J I; Jaroszewicz, Jacub; Anil, Sukumaran; Al Farraj Aldosari, Abdullah; Walboomers, X Frank; Jansen, John A

    2014-03-01

    The aims of this study were (i) to determine the spatial resolution and sensitivity of micro- versus nano-computed tomography (CT) techniques and (ii) to validate micro- versus nano-CT in a dog dental implant model, comparative to histological analysis. To determine spatial resolution and sensitivity, standardized reference samples containing standardized nano- and microspheres were prepared in polymer and ceramic matrices. Thereafter, 10 titanium-coated polymer dental implants (3.2 mm in Ø by 4 mm in length) were placed in the mandible of Beagle dogs. Both micro- and nano-CT, as well as histological analyses, were performed. The reference samples confirmed the high resolution of the nano-CT system, which was capable of revealing sub-micron structures embedded in radiodense matrices. The dog implantation study and subsequent statistical analysis showed equal values for bone area and bone-implant contact measurements between micro-CT and histology. However, because of the limited sample size and field of view, nano-CT was not rendering reliable data representative of the entire bone-implant specimen. Micro-CT analysis is an efficient tool to quantitate bone healing parameters at the bone-implant interface, especially when using titanium-coated PMMA implants. Nano-CT is not suitable for such quantification, but reveals complementary morphological information rivaling histology, yet with the advantage of a 3D visualization. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  7. Management of a nosocomial outbreak of Mycobacterium tuberculosis Beijing/W genotype in Taiwan: an emphasis on case tracing with high-resolution computed tomography.

    Science.gov (United States)

    Chen, Tun-Chieh; Lu, Po-Liang; Yang, Chih-Jen; Lin, Wei-Ru; Lin, Chun-Yu; Jou, Ruwen; Feng, Ming-Chu; Wang, Tung-Heng; Ho, Chi-Kung; Hwang, Jhi-Jhu; Chen, Yen-Hsu; Chiang, Horn-Che; Huang, Ming-Shyan; Chen, Tyen-Po

    2010-05-01

    A nosocomial outbreak of Mycobacterium tuberculosis Beijing/W genotype infected 15 healthcare workers (HCWs) in a medical center in Taiwan, where there is a high prevalence of tuberculosis and a high rate of positive tuberculin skin tests. An index patient with laryngeal cancer and a lung abscess was identified by epidemiological investigation and it was found that an M. tuberculosis isolate from his lung tissue sample had an identical IS6110 restriction fragment length polymorphism pattern to the isolates from 3 HCWs. Confirmation of the identity of this strain as Beijing/W genotype was made using spoligotyping. Seven hundred and eighty-five HCWs potentially exposed to the probable index patient received contact investigation and chest X-ray screening. We used chest high-resolution computed tomography (HRCT) to clarify trivial lesions in chest X-rays. Nine HCWs with smear-negative pulmonary tuberculosis were diagnosed by HRCT. Fifteen of the 35 (42.9%) HCWs with documented exposure to the index patient developed pulmonary tuberculosis within 11 months after exposure. The outbreak was successfully controlled by active case finding and enforcement of infection control strategies. Intervention to detect the potential tuberculosis source is helpful in the prevention and control of a nosocomial tuberculosis outbreak. HRCT can be a useful tool for tuberculosis diagnosis of contacts in an outbreak situation.

  8. Utility of the inspiratory phase in high-resolution computed tomography evaluations of pediatric patients with bronchiolitis obliterans after allogeneic bone marrow transplant: reducing patient radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Togni Filho, Paulo Henrique; Casagrande, Joao Luiz Marin; Lederman, Henrique Manoel, E-mail: paulotognifilho@gmail.com [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Dept. of Diagnostico por Imagem; Universidade de Sao Paulo (InRad/HC/FMUSP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Instituto de Radiologia

    2017-03-15

    Objective: To evaluate the utility of the inspiratory phase in high-resolution computed tomography (HRCT) of the chest for the diagnosis of post-bone marrow transplantation bronchiolitis obliterans. Materials and Methods: This was a retrospective, observational, cross-sectional study. We selected patients of either gender who underwent bone marrow transplantation and chest HRCT between March 1, 2002 and December 12, 2014. Ages ranged from 3 months to 20.7 years. We included all examinations in which the HRCT was performed appropriately. The examinations were read by two radiologists, one with extensive experience in pediatric radiology and another in the third year of residency, who determined the presence or absence of the following imaging features: air trapping, bronchiectasis, alveolar opacities, nodules, and atelectasis. Results: A total of 222 examinations were evaluated (mean, 5.4 ± 4.5 examinations per patient). The expiratory phase findings were comparable to those obtained in the inspiratory phase, except in one patient, in whom a small uncharacteristic nodule was identified only in the inspiratory phase. Air trapping was identified in a larger number of scans in the expiratory phase than in the inspiratory phase, as was atelectasis, although the difference was statistically significant only for air trapping. Conclusion: In children being evaluated for post-bone marrow transplantation bronchiolitis obliterans, the inspiratory phase can be excluded from the chest HRCT protocol, thus reducing by half the radiation exposure in this population. (author)

  9. Polarization properties of single layers in the posterior eyes of mice and rats investigated using high resolution polarization sensitive optical coherence tomography

    Science.gov (United States)

    Fialová, Stanislava; Augustin, Marco; Glösmann, Martin; Himmel, Tanja; Rauscher, Sabine; Gröger, Marion; Pircher, Michael; Hitzenberger, Christoph K.; Baumann, Bernhard

    2016-01-01

    We present a high resolution polarization sensitive optical coherence tomography (PS-OCT) system for ocular imaging in rodents. The system operates at 840 nm and uses a broadband superluminescent diode providing an axial resolution of 5.1 µm in air. PS-OCT data was acquired at 83 kHz A-scan rate by two identical custom-made spectrometers for orthogonal polarization states. Pigmented (Brown Norway, Long Evans) and non-pigmented (Sprague Dawley) rats as well as pigmented mice (C57BL/6) were imaged. Melanin pigment related depolarization was analyzed in the retinal pigment epithelium (RPE) and choroid of these animals using the degree of polarization uniformity (DOPU). For all rat strains, significant differences between RPE and choroidal depolarization were observed. In contrast, DOPU characteristics of RPE and choroid were similar for C57BL/6 mice. Moreover, the depolarization within the same tissue type varied significantly between different rodent strains. Retinal nerve fiber layer thickness, phase retardation, and birefringence were mapped and quantitatively measured in Long Evans rats in vivo for the first time. In a circumpapillary annulus, retinal nerve fiber layer birefringence amounted to 0.16°/µm ± 0.02°/µm and 0.17°/µm ± 0.01°/µm for the left and right eyes, respectively. PMID:27446670

  10. Computerized Tomography Technique for the Investigation of the Maxillary First Molar Mesiobuccal Root

    Directory of Open Access Journals (Sweden)

    Stefano Corbella

    2013-01-01

    Full Text Available The aim of this paper was to review the literature about the use of computerized tomography to evaluate the presence and characteristics of the second mesiobuccal canal in the maxillary first molar. An electronic search was performed. Frequencies of the presence of second mesiobuccal canal and root anatomy characteristics were extracted from the selected studies. Pooled frequencies were calculated as weighted means. Seven articles were included. A second mesiobuccal canal was present in 59.32% of the teeth, and it was noncommunicating in 58.45% of teeth presenting the canal itself. The most common root canal morphology was single canal or two separated canals. The present paper showed that cone beam CT is a viable radiologic device for the evaluation of the mesiobuccal root of maxillary first molars. In fact, it was observed that the frequency of second mesiobuccal canal detection is similar to those presented by clinical studies or micro-CT evaluations.

  11. The influence of species composition on flow field's optical computerized tomography diagnosis

    Science.gov (United States)

    Yun-yun, Chen; Fang, Gu; Ling-bing, Bu; Ying-ying, Zhang

    2017-07-01

    The species composition is one of the factors which could affect the refractive index of flow fields. So, the determination of species composition should be a key point, when optical computerized tomography (OCT) methods are applied to measure the key parameters of flow fields. In this paper, the influence of species composition on flow field's temperature diagnosis will be discussed both in theory and experiment. The final results manifest that the determination of species composition could affect not only the specific temperature values, but also the structure and distribution of the temperature. Meanwhile, it is also found that the nonlinear regular of the maximal temperature variation with the distance between the cross section and nozzle is the same in different models. Finally, the condition, which could be applied to judge whether the effect of species composition can be omitted, is proposed.

  12. Computerized tomography, stereolithography and dental implants in the rehabilitation of oral cancer patients.

    Science.gov (United States)

    Patel, Mital; Al-Momani, Zaid; Hodson, Nicholas; Nixon, Peter; Mitchell, David

    2013-09-01

    As survival rates improve it is important to consider the quality of life for oral cancer patients post-treatment. The primary goal is removal of the tumour, however, with a gradual increase in survival rates, post-operative rehabilitation is now becoming increasingly important. Specialists in restorative dentistry, along with oral and maxillofacial surgeons, general dental practitioners and other members of the multidisciplinary team play a vital role in planning treatment for, and rehabilitating, these patients. This paper presents a case series to show how recent advances in computerized tomography (CT) and the use of stereolithographic models can help in the rehabilitation of oral cancer patients. The principles discussed can also be applied to other patients undergoing dental implant treatment to help plan and carry out treatment and improve the quality of peri-implant tissues.

  13. A water-soluble triiodo amino acid and its dendrimer conjugate for computerized tomography (CT imaging

    Directory of Open Access Journals (Sweden)

    MARTIN W. BRECHBIEL

    2005-02-01

    Full Text Available Prolonging the circulation of an imaging agent is vital for making it suitable for blood pool (vascular imaging. Medical applications of vascular imaging include cardiovascular disease, abnormal capillary permeability, and tumor neovascularity. As low molecular weight computerized tomography (CT enhancement agents are characterized by inconveniently fast clearance, macromolecular compounds (both natural and synthetic have gained a wide recongnition for possessing better characteristics for performing blood imaging tasks. Herein, the syntheses and characterization of a new water-soluble triiodo amino acid, 3-[(N,N-dimethylaminoacetyl amino]-a-ethyl-2,4,6-triiodobenzenepropanoic acid (DMAA-IPA and its Starburst PAMAMgeneration 4.0 dendrimer conjugate, G-4-(DMAA-IPA37 are described. The applicability of G-4-(DMAA-IPA37 as a potential macromolecular angiographic CT contrast agent is discussed. The linear relationship between organically bound iodine concentration and CT Hounsfield units has been established thus allowing for quantification uses of CT imaging as well.

  14. Dose evaluation in diagnostic for computerized tomography; Evaluacion de dosis en diagnostico por tomografia computarizada

    Energy Technology Data Exchange (ETDEWEB)

    Flores, W.; Borges, J.C.; Mota, H. [Universidad Federal de Rio de Janeiro, PEN/COPPE/UFRJ. Caixa Postal 68509. 21945-970 Rio de Janeiro (Brazil)

    1998-12-31

    The patients which are subjected to computerized tomography tests are exposed to relatively high doses given as result doses on organs that are not matter to test. It was realized a dose levels raising in patients subjected to tests by T C, utilizing to measure this magnitude, TLD-100 thermoluminescent dosemeters which were put directly on the patient, in eye regions, thyroid, breast and navel; founding doses fluctuating between 29.10-49.39 mGy in organs examined and dose values between 0.21-29.10 mGy for organs that no matter to test. The applications of ionizing radiations in medicine do not have dose limits, but paying attention to the radiological protection optimization principle, it is recommended the use of clothes to anti-rays protection for zones not examined, getting with this to reduce the level doses as low as possible, without this to diminish the test quality. (Author)

  15. Planosol soil sample size for computerized tomography measurement of physical parameters

    Directory of Open Access Journals (Sweden)

    Pedrotti Alceu

    2003-01-01

    Full Text Available Computerized tomography (CT is an important tool in Soil Science for noninvasive measurement of density and water content of soil samples. This work aims to describe the aspects of sample size adequacy for Planosol (Albaqualf and to evaluate procedures for statistical analysis, using a CT scanner with a 241Am source. Density errors attributed to the equipment are 0.051 and 0.046 Mg m-3 for horizons A and B, respectively. The theoretical value for sample thickness for the Planosol, using this equipment, is 4.0 cm for the horizons A and B. The ideal thickness of samples is approximately 6.0 cm, being smaller for samples of the horizon B in relation to A. Alternatives for the improvement of the efficiency analysis and the reliability of the results obtained by CT are also discussed, and indicate good precision and adaptability of the application of this technology in Planosol (Albaqualf studies.

  16. A motion artefact study and locally deforming objects in computerized tomography

    Science.gov (United States)

    Hahn, Bernadette N.

    2017-11-01

    Movements of the object during the data collection in computerized tomography can introduce motion artefacts in the reconstructed image. They can be reduced by employing information about the dynamic behaviour within the reconstruction step. However, inaccuracies concerning the movement are inevitable in practice. In this article, we give an explicit characterization of what is visible in an image obtained by a reconstruction algorithm with incorrect motion information. Then, we use this result to study in detail the situation of locally deforming objects, i.e. individual parts of the object have a different dynamic behaviour. In this context, we prove that additional artefacts arise due to the global nature of the Radon transform, even if the motion is exactly known. Based on our analysis, we propose a numerical scheme to reduce these artefacts in the reconstructed image. All our results are illustrated by numerical examples.

  17. Renal calyceal anatomy characterization with 3-dimensional in vivo computerized tomography imaging.

    Science.gov (United States)

    Miller, Joe; Durack, Jeremy C; Sorensen, Mathew D; Wang, James H; Stoller, Marshall L

    2013-02-01

    Calyceal selection for percutaneous renal access is critical for safe, effective performance of percutaneous nephrolithotomy. Available anatomical evidence is contradictory and incomplete. We present detailed renal calyceal anatomy obtained from in vivo 3-dimentional computerized tomography renderings. A total of 60 computerized tomography urograms were randomly selected. The renal collecting system was isolated and 3-dimensional renderings were constructed. The primary plane of each calyceal group of 100 kidneys was determined. A coronal maximum intensity projection was used for simulated percutaneous access. The most inferior calyx was designated calyx 1. Moving superiorly, the subsequent calyces were designated calyx 2 and, when present, calyx 3. The surface rendering was rotated to assess the primary plane of the calyceal group and the orientation of the select calyx. The primary plane of the upper pole calyceal group was mediolateral in 95% of kidneys and the primary plane of the lower pole calyceal group was anteroposterior in 95%. Calyx 2 was chosen in 90 of 97 simulations and it was appropriate in 92%. Calyx 3 was chosen in 7 simulations but it was appropriate in only 57%. Calyx 1 was not selected in any simulation and it was anteriorly oriented in 75% of kidneys. Appropriate lower pole calyceal access can be reliably accomplished with an understanding of the anatomical relationship between individual calyceal orientation and the primary plane of the calyceal group. Calyx 2 is most often appropriate for accessing the anteroposterior primary plane of the lower pole. Calyx 1 is most commonly oriented anterior. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Architecture of a Dual-Modality, High-Resolution, Fully Digital Positron Emission Tomography/Computed Tomography (PET/CT) Scanner for Small Animal Imaging

    Science.gov (United States)

    Fontaine, R.; Belanger, F.; Cadorette, J.; Leroux, J.-D.; Martin, J.-P.; Michaud, J.-B.; Pratte, J.-F.; Robert, S.; Lecomte, R.

    2005-06-01

    Contemporary positron emission tomography (PET) scanners are commonly implemented with very large scale integration analog front-end electronics to reduce power consumption, space, noise, and cost. Analog processing yields excellent results in dedicated applications, but offers little flexibility for sophisticated signal processing or for more accurate measurements with newer, fast scintillation crystals. Design goals of the new Sherbrooke PET/computed tomography (CT) scanner are: 1) to achieve 1 mm resolution in both emission (PET) and transmission (CT) imaging using the same detector channels; 2) to be able to count and discriminate individual X-ray photons in CT mode. These requirements can be better met by sampling the analog signal from each individual detector channel as early as possible, using off-the-shelf, 8-b, 100-MHz, high-speed analog-to-digital converters (ADC) and digital processing in field programmable gate arrays (FPGAs). The core of the processing units consists of Xilinx SpartanIIe that can hold up to 16 individual channels. The initial architecture is designed for 1024 channels, but modularity allows extending the system up to 10 K channels or more. This parallel architecture supports count rates in excess of a million hits/s/scintillator in CT mode and up to 100 K events/s/scintillator in PET mode, with a coincidence time window of less than 10 ns full-width at half-maximum.

  19. In vivo visualization of photoreceptor layer and lipofuscin accumulation in Stargardt’s disease and fundus flavimaculatus by high resolution spectral-domain optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Giuseppe Querques

    2009-12-01

    Full Text Available Giuseppe Querques, Rosy Prato, Gabriel Coscas, Gisèle Soubrane, Eric H SouiedDepartment of Ophthalmology, Hopital Intercommunal de Creteil, University Paris XII, FranceIntroduction: To assess photoreceptor (PR layer morphology in patients with Stargardt’s disease (STGD and fundus flavimaculatus (FFM using high resolution spectral domain optical coherence tomography (HD-OCT; OCT 4000 Cirrus, Humphrey-Zeiss, San Leandro, CA.Methods: This was a prospective observational case series. Sixteen consecutive patients with STGD and FFM underwent a complete ophthalmologic examination. Optical coherence tomography examination was performed with HD-OCT, a high-speed (27,000 axial scans per second OCT system using spectral/Fourier domain detection, with an axial image resolution of 5 µm.Results: A total of 31 eyes were included in the study. Transverse loss of the PR layer in the foveal region was shown by HD-OCT. Twenty eyes with clinically evident central atrophy had a disruption of either the Verhoeff‘s membrane (VM or the layer corresponding to the interface of inner segment (IS and outer segment (OS of PR in the foveal region. Among these eyes, 12/20 eyes had a loss of the PR layer (loss of both VM and IS-OS interface in the foveal region. Eleven eyes (11/31 without clinically evident central atrophy had an intact interface of IS and OS of PR centrally. Moreover, we observed hyperreflective deposits: type 1 lesions located within the retinal pigment epithelium (RPE layer and at the level of the outer segments of PR, and type 2 lesions located at the level of the outer nuclear layer and clearly separated from the RPE layer. Type 1 lesions alone were associated with absence of loss of the PR layer in the foveal region in all eyes; type 2 lesions were always associated with presence of type 1 lesions, and often (8/12 eyes associated with loss of the PR layer within the foveal region. Mean best-corrected visual acuity (BCVA was significantly

  20. Weight-based contrast administration in the computerized tomography evaluation of acute pulmonary embolism

    Science.gov (United States)

    Laurent, Lisa; Zamfirova, Ina; Sulo, Suela; Baral, Pesach

    2017-01-01

    Abstract Compare individualized contrast protocol, or weight-based protocol, to standard methodology in evaluating acute pulmonary embolism. Retrospective chart review was performed on patients undergoing computed tomography angiography with standard contrast protocol (n = 50) or individualized protocol (n = 50). Computerized tomography images were assessed for vascular enhancement and image quality. Demographics were comparable, however, more patients in the individualized group were admitted to intensive care unit (48% vs 16%, P = 0.004). Vascular enhancement and image quality were also comparable, although individualized protocol had significantly fewer contrast and motion artifact limitations (28% vs 48%, P = 0.039). Fifteen percent decrease in intravenous contrast volume was identified in individualized group with no compromise in image quality. Individualized contrast protocol provided comparable vascular enhancement and image quality to the standard, yet with fewer limitations and lower intravenous contrast volume. Catheter-gauge flow rate restrictions resulting in inconsistent technologist exam execution were identified, supporting the need for further investigation of this regimen. PMID:28151887

  1. Screening for lymphangioleiomyomatosis by high-resolution computed tomography in young, nonsmoking women presenting with spontaneous pneumothorax is cost-effective.

    Science.gov (United States)

    Hagaman, Jared T; Schauer, Daniel P; McCormack, Francis X; Kinder, Brent W

    2010-06-15

    Women with pulmonary lymphangioleiomyomatosis (LAM) who present with a sentinel spontaneous pneumothorax (SPTX) will experience an average of 2.5 additional pneumothoraces. The diagnosis of LAM is typically delayed until after the second pneumothorax. We hypothesized that targeted screening of an LAM-enriched population of nonsmoking women between the ages of 25 and 54 years, who present with a sentinel pneumothorax indicated by high-resolution computed tomography (HRCT), will facilitate early identification, definitive therapy, and improved quality of life for patients with LAM. We constructed a Markov state-transition model to assess the cost-effectiveness of screening. Rates of SPTX and prevalence of LAM in populations stratified by age, sex, and smoking status were derived from the literature. Costs of testing and treatment were extracted from 2007 Medicare data. We compared a strategy based on HRCT screening followed by pleurodesis for patients with LAM, versus no HRCT screening. The prevalence of LAM in nonsmoking women, between the ages of 25 and 54 years, with SPTX is estimated at 5% on the basis of the available literature. In our base case analysis, screening for LAM by HRCT is the most cost-effective strategy, with a marginal cost-effectiveness ratio of $32,980 per quality-adjusted life-year gained. Sensitivity analysis showed that HRCT screening remains cost-effective for groups in which the prevalence of LAM in the population subset screened is greater than 2.5%. Screening for LAM by HRCT in nonsmoking women age 25-54 that present with SPTX is cost-effective. Physicians are advised to screen for LAM by HRCT in this population.

  2. High-resolution computed tomography and rheumatoid arthritis: semi-quantitative evaluation of lung damage and its correlation with clinical and functional abnormalities.

    Science.gov (United States)

    Yilmazer, Baris; Gümüştaş, Sevtap; Coşan, Fulya; İnan, Nagihan; Ensaroğlu, Fatih; Erbağ, Gökhan; Yıldız, Füsun; Çefle, Ayşe

    2016-03-01

    We aimed to establish risk factors for radiological lung damage associated with rheumatoid arthritis (RA) and determine whether clinical findings and pulmonary function test were correlated with Warrick score calculated on the basis of high-resolution computed tomography or not. One hundred thirty RA patients who were followed at rheumatology outpatient clinic were included through retrospective screening. To evaluate radiological involvement, the semi-quantitative evaluation proposed by Warrick was used to assign a score for each lesion based on the severity and extent of the pulmonary damage. In addition to the total score, indices for alveolitis and fibrosis were created. The correlations between each score and clinical and functional parameters were tested for all patients. We showed that age was an independent explanatory variable of radiological lung damage. Percentage of predicted lung diffusion capacity for carbon monoxide (DLco) below 75 % and presence of respiratory symptoms were found to contribute more to radiological lung damage. Warrick score was positively correlated with age at study onset (r = 0.43, p < 0.001). In addition, a negative correlation was found between Warrick score and DLco % predicted (r = -0.357, p = 0.001). Alveolitis index was negatively correlated with DLco % predicted (r = -0.321, p = 0.003). It is considered that this semi-quantitative method may have added value in early diagnosis, appropriate treatment decisions and follow-up when taken into account together with risk factors associated with pulmonary damage in RA.

  3. High resolution spectral domain optical coherence tomography (SD-OCT in multiple sclerosis: the first follow up study over two years.

    Directory of Open Access Journals (Sweden)

    Nermin Serbecic

    Full Text Available BACKGROUND: "Non-invasive, faster and less expensive than MRI" and "the eye is a window to the brain" are recent slogans promoting optical coherence tomography (OCT as a new surrogate marker in multiple sclerosis (MS. Indeed, OCT allows for the first time a non-invasive visualization of axons of the central nervous system (CNS. Reduction of retina nerve fibre layer (RNFL thickness was suggested to correlate with disease activity and duration. However, several issues are unclear: Do a few million axons, which build up both optic nerves, really resemble billions of CNS neurons? Does global CNS damage really result in global RNFL reduction? And if so, does global RNFL reduction really exist in all MS patients, and follow a slowly but steadily ongoing pattern? How can these (hypothesized subtle global RNFL changes be reliably measured and separated from the rather gross RNFL changes caused by optic neuritis? Before generally being accepted, this interpretation needs further critical and objective validation. METHODOLOGY: We prospectively studied 37 MS patients with relapsing remitting (n = 27 and secondary progressive (n = 10 course on two occasions with a median interval of 22.4±0.5 months [range 19-27]. We used the high resolution spectral domain (SD-OCT with the Spectralis 3.5 mm circle scan protocol with locked reference images and eye tracking mode. Patients with an attack of optic neuritis within 12 months prior to the onset of the study were excluded. PRINCIPAL FINDINGS: Although the disease was highly active over the observation period in more than half of the included relapsing remitting MS patients (19 patients/32 relapses and the initial RNFL pattern showed a broad range, from normal to markedly reduced thickness, no significant changes between baseline and follow-up examinations could be detected. CONCLUSIONS: These results show that caution is required when using OCT for monitoring disease activity and global axonal injury in

  4. Reader Accuracy and Confidence in Diagnosing Diffuse Lung Disease on High-Resolution Computed Tomography of the Lungs: Impact of Sampling Frequency

    Energy Technology Data Exchange (ETDEWEB)

    Sundaram, B.; Gross, B.H.; Oh, E.; Mueller, N.; Myles, J.D.; Kazerooni, E.A. (Dept. of Radiology, Michigan Institute for Clinical Health Research, Univ. of Michigan Health System, Ann Arbor, Michigan (United States))

    2008-10-15

    Background: The accuracy of the number of high-resolution computed tomography (HRCT) images necessary to diagnose diffuse lung disease (DLD) is not well established. Purpose: To evaluate the impact of HRCT sampling frequency on reader confidence and accuracy for diagnosing DLD. Material and Methods: HRCT images of 100 consecutive patients with proven DLD were reviewed. They were: 48 usual interstitial pneumonia, 22 sarcoidosis, six hypersensitivity pneumonitis, five each of desquamative interstitial pneumonitis, eosinophilic granulomatosis, and lymphangioleiomyomatosis, and nine others. Inspiratory images at 1-cm increments throughout the lungs and three specified levels formed complete and limited examinations. In random order, three experts (readers 1, 2, and 3) ranked their top three diagnoses and rated confidence for their top diagnosis, independently and blinded to clinical information. Results: Using the complete versus limited examinations for correct first-choice diagnosis, accuracy for reader 1 (R1) was 81% versus 80%, respectively, for reader 2 (R2) 70% versus 70%, and for reader 3 (R3) 64% versus 59%. Reader accuracy within their top three choices for complete versus limited examinations was: R1 91% versus 91% of cases, respectively, R2 84% versus 83%, and R3 79% versus 72% of cases. No statistically significant differences were found between the diagnosis methods (P=0.28 for first diagnosis and P=0.17 for top three choices). The confidence intervals for individual raters showed considerable overlap, and the point estimates are almost identical. The mean interreader agreement for complete versus limited HRCT for both top and top three diagnoses were the same (moderate and fair, respectively). The mean intrareader agreement between complete and limited HRCT for top and top three diagnoses were substantial and moderate, respectively. Conclusion: Overall reader accuracy and confidence in diagnosis did not significantly differ when fewer or more HRCT images

  5. Rheumatoid arthritis-associated interstitial lung disease: lung inflammation evaluated with high resolution computed tomography scan is correlated to rheumatoid arthritis disease activity.

    Science.gov (United States)

    Pérez-Dórame, Renzo; Mejía, Mayra; Mateos-Toledo, Heidegger; Rojas-Serrano, Jorge

    2015-01-01

    To describe the association between rheumatoid arthritis disease activity (RA) and interstitial lung damage (inflammation and fibrosis), in a group of patients with rheumatoid arthritis-associated interstitial lung disease (RA-ILD). A retrospective study of RA patients with interstitial lung disease (restrictive pattern in lung function tests and evidence of interstitial lung disease in high resolution computed tomography (HRCT)). Patients were evaluated to exclude other causes of pulmonary disease. RA disease activity was measured with the CDAI index. Interstitial lung inflammation and fibrosis were determined by Kazerooni scale. We compared Kazerooni ground-glass score with the nearest CDAI score to HRCT date scan of the first medical evaluation at our institution. In nine patients, we compared the first ground-glass score with a second one after treatment with DMARDs and corticosteroids. Spearman's rank correlation coefficient was used to evaluate association between RA disease activity and the Kazerooni ground-glass and fibrosis scores. Thirty-four patients were included. A positive correlation between CDAI and ground-glass scores was found (rs=0.3767, P<0.028). Fibrosis and CDAI scores were not associated (rs=-0.0747, P<0.6745). After treatment, a downward tendency in the ground-glass score was observed (median [IQR]): (2.33 [2,3] vs. 2 [1.33-2.16]), P<0.056, along with a lesser CDAI score (27 [8-43] vs. 9 [5-12]), P<0.063. There is a correlation between RA disease activity and ground-glass appearance in the HRCT of RA-ILD patients. These results suggest a positive association between RA disease activity and lung inflammation in RA-ILD. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  6. Lung disease assessment in primary ciliary dyskinesia: a comparison between chest high-field magnetic resonance imaging and high-resolution computed tomography findings

    Directory of Open Access Journals (Sweden)

    Iacotucci Paola

    2009-08-01

    Full Text Available Abstract Background Primary ciliary dyskinesia (PCD is associated with pulmonary involvement that requires periodical assessment. Chest high-resolution computed tomography (HRCT has become the method of choice to evaluate chronic lung disease, but entails exposure to ionizing radiation. Magnetic resonance imaging (MRI has been proposed as a potential radiation-free technique in several chest disorders. Aim of our study is to evaluate whether high-field MRI is as effective as HRCT in identifying PCD pulmonary abnormalities. We also analyzed the relationships between the severity and extension of lung disease, and functional data. Methods Thirteen PCD patients (8 children/5 adults; median age, 15.2 yrs underwent chest HRCT and high-field 3T MRI, spirometry, and deep throat or sputum culture. Images were scored using a modified version of the Helbich system. Results HRCT and MRI total scores were 12 (range, 6–20 and 12 (range, 5–17, respectively. Agreement between HRCT and MRI scores was good or excellent (r > 0.8. HRCT and MRI total scores were significantly related to forced vital capacity (r = -0.5, p = 0.05; and r = -0.7, p = 0.009, respectively and forced expiratory volume at 1 second (r = -0.6, p = 0.03; and r = -0.7, p = 0.009, respectively. Conclusion Chest high-field 3T MRI appears to be as effective as HRCT in assessing the extent and severity of lung abnormalities in PCD. MRI scores might be used for longitudinal assessment and be an outcome surrogate in future studies.

  7. Reproducible metacarpal joint space width measurements using 3D analysis of images acquired with high-resolution peripheral quantitative computed tomography.

    Science.gov (United States)

    Barnabe, Cheryl; Buie, Helen; Kan, Michelle; Szabo, Eva; Barr, Susan G; Martin, Liam; Boyd, Steven K

    2013-10-01

    Joint space narrowing is an important feature of progressive joint damage and functional impairment in rheumatoid arthritis (RA). Methods to provide a continuous measurement of joint space width have not been adopted in research or clinical settings. High-resolution peripheral quantitative computed tomography (HR-pQCT) (Scanco Medical AG, Brüttisellen, Switzerland) accurately and reproducibly images bone microstructure at a nominal isotropic voxel dimension of 82 μm. Given the ability of HR-pQCT to detect bone margins with high precision, we developed methodology to measure a three-dimensional (3D) metacarpophalangeal (MCP) joint space width and tested the reproducibility of the scan protocol with hand repositioning. Consecutive HR-pQCT scans of the 2nd and 3rd MCP joints of ten subjects with early RA (70% female, mean age 45 years), with repositioning between scans, were obtained. The periosteal edges of the metacarpal head and proximal phalanx base were detected using the μCT Evaluation Program V6.0 (Scanco Medical AG). Using the method of 'fitting maximal spheres', the joint space width and distribution of joint space thickness was estimated. The mean minimum joint space width of the 2nd MCP was 1.82 mm (SD 0.20) and of the 3rd MCP 1.84 mm (SD 0.23). Reproducibility with repositioning was reliable, with overlapping filtered histograms and a root square mean coefficient of variance of 4.8%. We provide reproducible methodology for evaluating the joint space width of the MCP joints. When combined with the assessment of erosions and periarticular bone density, HR-pQCT may be the ideal technology to assess disease activity and progression in RA. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Comparison of high-resolution and standard zoom imaging modes in cone beam computed tomography for detection of longitudinal root fracture: An in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Taramsari, Mehran; Kajan, Zahra Dalili; Bashizadeh, Parinaz [Faculty of Dentistry, Guilan University of Medical Sciences, Rasht (Iran, Islamic Republic of); Salamat, Fatemeh [Vice Chancellor of Research and Technology, Guilan University of Medical Sciences, Rasht (Iran, Islamic Republic of)

    2013-09-15

    The purpose of this study was to compare the efficacy of two imaging modes in a cone beam computed tomography (CBCT) system in detecting root fracture in endodontically-treated teeth with fiber posts or screw posts by selecting two fields of view. In this study, 78 endodontically-treated single canal premolars were included. A post space was created in all of them. Then the teeth were randomly set in one of 6 artificial dental arches. In 39 of the 78 teeth set in the 6 dental arches, a root fracture was intentionally created. Next, a fiber post and a screw post were cemented into 26 teeth having equal the root fractures. High resolution (HiRes) and standard zoom images were provided by a CBCT device. Upon considering the reconstructed images, two observers in agreement with each other confirmed the presence or absence of root fracture. A McNemar test was used for comparing the results of the two modes. The frequency of making a correct diagnosis using the HiRes zoom imaging mode was 71.8% and in standard zoom was 59%. The overall sensitivity and specificity in diagnosing root fracture in the HiRes mode were 71.79% and 46.15% and in the standard zoom modes were 58.97% and 33.33%, respectively. There were no significant differences between the diagnostic values of the two imaging modes used in the diagnosis of root fracture or in the presence of root canal restorations. In both modes, the most true-positive results were reported in the post space group.

  9. Conversion factors for determining organ doses received by paediatric patients in high-resolution single slice computed tomography with narrow collimation

    Energy Technology Data Exchange (ETDEWEB)

    Seidenbusch, Michael C.; Schneider, Karl [Muenchen Univ. (Germany). Paediatric Radiology; Harder, Dietrich [Goettingen Univ. (Germany). Medical Physics and Biophysics; Regulla, Dieter F. [Helmholtz Zentrum Muenchen German Research Center for Environmental Health, Neuherberg (Germany). Research Unit Medical Radiation Physics and Diagnostics

    2014-09-01

    Estimations of organ doses D{sub T} received during computed tomographic examinations are usually performed by applying conversion factors to basic dose indicators like the computed tomography dose index (CTDI) or the dose-length-product (DLP). In addition to the existing conversion factors for beam apertures of 5 mm or 10 mm, we present new DLP-D{sub T} conversion factors adapted to high-resolution CT (HRCT) examinations of infants and young children with beam apertures of the order of 1 mm and under consideration of bow tie filtration. Calculations are performed on mathematical MIRD phantoms for an age range from 0, 1, 5, 10, 15 up to (for comparison) 30 years by adapting PCXMC, a Monte Carlo algorithm originally developed by STUK (Helsinki, Finland) for dose reconstructions in projection radiography. For this purpose, each single slice CT examination is approximated by a series of corresponding virtual planar radiographies comprising all focus positions. The transformation of CT exposure parameters into exposure parameters of the series of corresponding planar radiographies is performed by a specially developed algorithm called XCT. The DLP values are evaluated using the EGSRay code. The new method is verified at a beam aperture of 10 mm by comparison with formerly published conversion factors. We show that the higher spatial resolution leads to an enhanced DLP-D{sub T} conversion factor if a small organ (e.g. thyroid gland, mammae, uterus, ovaries, testes) is exactly met by the chosen CT slice, while the conversion factor is drastically reduced if the chosen CT slice is positioned above or below the organ. This effect is utilized for dose-saving examinations with only a few single slices instead a full scan, which technique is applied in about 10% of all paediatric chest CT examinations. (orig.)

  10. Hyperbaric oxygen treatment attenuated the decrease in regional glucose metabolism of rats subjected to focal cerebral ischemia: a high resolution positron emission tomography study.

    Science.gov (United States)

    Lou, M; Zhang, H; Wang, J; Wen, S-Q; Tang, Z-Q; Chen, Y-Z; Yan, W-Q; Ding, M-P

    2007-05-11

    Cerebral hypoxia may be the main component of cell damage caused by ischemia. Previous studies demonstrated a neuroprotective effect of early hyperbaric oxygen (HBO) treatment in various animal models of focal cerebral ischemia. Neuropathologic study showed that exposure of HBO may prevent cell death in ischemic cortex. In the present study, we aimed to assess cellular function of ischemic rat brain after HBO treatment by means of a high-resolution positron emission tomography scanner (microPET) used specifically for small animal imaging. The male Sprague-Dawley rats were subjected to permanent middle cerebral artery occlusion (MCAO), with the regional cerebral blood flow monitored in vivo by laser Doppler flowmetry. One hour after ischemia, HBO therapy (3 atm absolute, 1 h) was initiated. Local cerebral glucose utilization in the ischemic area was measured before, 1 h and 3 h after ischemia, with 2-[(18)F]-fluoro-2-deoxy-d-glucose (FDG) as a tracer. Neurological deficits and infarct volumes were assessed at 24 h after ischemia. Our study showed that early HBO therapy significantly reduced infarct volume of brain 24 h after ischemia. Moreover, glucose utilization in the ischemic area underwent a severe decrease during 1-3 h after MCAO, while the early HBO treatment significantly attenuated the decrease in cerebral metabolic rate of glucose in the ischemic core of the cortex compared with controls. We report for the first time the application of microPET to quantify the rates of glucose metabolism in the ischemic core of rats exposed to HBO. Our results suggest that the early exposure of HBO can partially reverse the downward trend for glucose utilization in the ischemic core, which might contribute to the reported beneficial effects of early HBO therapy on permanent cerebral ischemia.

  11. Edema pulmonar hidrostático: aspectos na tomografia computadorizada de alta resolução Hydrostatic pulmonary edema: high-resolution computed tomography aspects

    Directory of Open Access Journals (Sweden)

    Cláudia Maria Cunha Ribeiro

    2006-12-01

    Full Text Available OBJETIVO: A proposta deste estudo foi caracterizar por meio de tomografia computadorizada de alta resolução do tórax as principais alterações pulmonares do edema pulmonar hidrostático. MÉTODOS: Foram analisadas, retrospectivamente, as tomografias de quinze pacientes com quadro clínico de edema pulmonar hidrostático, divididos em cinco principais grupos etiológicos: insuficiência cardíaca congestiva, valvulopatia mitral aguda, infarto agudo do miocárdio, miocardite e mediastinite fibrosante, tendo sido sete pacientes classificados no primeiro grupo e dois em cada um dos demais. RESULTADOS: Os principais achados do edema hidrostático foram opacidades em vidro fosco (100%, espessamento dos septos interlobulares (100%, derrame pleural (87% e espessamento do interstício peribroncovascular (80%. Outros achados menos comuns foram aumento do calibre dos vasos, consolidações e nódulos do espaço aéreo. CONCLUSÃO: O padrão predominante encontrado nos pacientes estudados foi o de opacidades em vidro fosco associadas a espessamento dos septos interlobulares (padrão de pavimentação em mosaico, com derrame pleural bilateral, predominante à direita.OBJECTIVE: This study aimed to use high-resolution computed tomography scans of the chest to characterize the principal alterations occurring in cases of hydrostatic pulmonary edema. METHODS: A retrospective analysis was made of the tomography scans of 15 patients presenting clinical profiles of hydrostatic pulmonary edema. The cases were divided into five groups by etiology: congestive heart failure (n = 7; acute mitral valve disease (n = 2; acute myocardial infarction (n = 2; myocarditis (n = 2; and fibrosing mediastinitis (n = 2. RESULTS: The principal findings in the cases of hydrostatic pulmonary edema were ground-glass opacities (in 100%, interlobular septal thickening (in 100%, pleural effusion (in 87% and peribronchovascular interstitial thickening (in 80%. Other, less common

  12. Novel Application of Micro-Computerized Tomography for Morphologic Characterization of the Murine Penis.

    Science.gov (United States)

    O'Neill, Marisol; Huang, Gene O; Lamb, Dolores J

    2017-12-01

    The murine penis model has enriched our understanding of anomalous penile development. The morphologic characterization of the murine penis using conventional serial sectioning methods is labor intensive and prone to errors. To develop a novel application of micro-computerized tomography (micro-CT) with iodine staining for rapid, non-destructive morphologic study of murine penis structure. Penises were dissected from 10 adult wild-type mice and imaged using micro-CT with iodine staining. Images were acquired at 5-μm spatial resolution on a Bruker SkyScan 1272 micro-CT system. After images were acquired, the specimens were washed of any remaining iodine and embedded in paraffin for conventional histologic examination. Histologic and micro-CT measurements for all specimens were made by 2 independent observers. Measurements of penile structures were made on virtual micro-CT sections and histologic slides. The Lin concordance correlation coefficient demonstrated almost perfect strength of agreement for interobserver variability for histologic section (0.9995, 95% CI = 0.9990-0.9997) and micro-CT section (0.9982, 95% CI = 0.9963-0.9991) measurements. Bland-Altman analysis for agreement between the 2 modalities of measurement demonstrated mean differences of -0.029, 0.022, and -0.068 mm for male urogenital mating protuberance, baculum, and penile glans length, respectively. There did not appear to be a bias for overestimation or underestimation of measured lengths and limits of agreement were narrow. The enhanced ability offered by micro-CT to phenotype the murine penis has the potential to improve translational studies examining the molecular pathways contributing to anomalous penile development. The present study describes the first reported use of micro-CT with iodine staining for imaging the murine penis. Producing repeated histologic sections of identical orientation was limited by inherent imperfections in mounting and tissue sectioning, but this was

  13. Variable-resolution cone-beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model.

    Science.gov (United States)

    Wenzel, Ann; Haiter-Neto, Fransisco; Frydenberg, Morten; Kirkevang, Lise-Lotte

    2009-12-01

    The aim of this study was to compare the diagnostic accuracy of an intraoral photostimulable storage phosphor (PSP) plate system and cone-beam computerized tomography scanning (CBCT) for detection of experimentally induced transverse root fractures and to evaluate differences between original images and images enhanced with high-pass filters. Sixty-nine extracted human teeth, 34 with root fractures and 35 without, were examined under standardized conditions using an intraoral PSP system (Digora Optime; Soredex). The images were saved in original 8-bit format and in a version sharpened with a high-pass filter. The teeth were examined with CBCT (i-Cat; Imaging Sciences) in 2 resolutions: 0.125 mm and 0.25 mm voxel size. Original images were saved together with images enhanced with 2 high-pass filters, sharpen and angio-sharpen. Six observers scored the presence of a root fracture in all modalities in random order. Sensitivity, specificity, and accuracy [(true positives + true negatives)/all scores] were calculated for each modality and each observer. Differences were estimated by analyzing the binary data, assuming additive effects of observer and modality in a generalized linear model. High-resolution original CBCT images had higher sensitivity (P < .05) than lower-resolution images and PSP images (0.125 mm resolution 87%, 0.25 mm resolution 72%, and PSP 74%). Angio-sharpen-filtered images for both CBCT resolutions had higher sensitivities (P < .02) than the original images (0.125 mm resolution: 95% vs. 87%; 0.25 mm resolution: 81% vs. 72%). There was no significant difference between the lower-resolution CBCT and PSP images. Only small differences in specificity were seen between modalities, and accuracy was higher for high-resolution CBCT than for the other modalities (P < .03). High-resolution i-Cat CBCT images resulted in an increase in sensitivity without jeopardizing specificity for detection of transverse root fractures compared with lower-resolution CBCT

  14. UT-CT: A National Resource for Applications of High-Resolution X-ray Computed Tomography in the Geological Sciences

    Science.gov (United States)

    Carlson, W. D.; Ketcham, R. A.; Rowe, T. B.

    2002-12-01

    An NSF-sponsored (EAR-IF) shared multi-user facility dedicated to research applications of high-resolution X-ray computed tomography (CT) in the geological sciences has been in operation since 1997 at the University of Texas at Austin. The centerpiece of the facility is an industrial CT scanner custom-designed for geological applications. Because the instrument can optimize trade-offs among penetrating ability, spatial resolution, density discrimination, imaging modes, and scan times, it can image a very broad range of geological specimens and materials, and thus offers significant advantages over medical scanners and desktop microtomographs. Two tungsten-target X-ray sources (200-kV microfocal and 420-kV) and three X-ray detectors (image-intensifier, high-sensitivity cadmium tungstate linear array, and high-resolution gadolinium-oxysulfide radiographic line scanner) can be used in various combinations to meet specific imaging goals. Further flexibility is provided by multiple imaging modes: second-generation (translate-rotate), third-generation (rotate-only; centered and variably offset), and cone-beam (volume CT). The instrument can accommodate specimens as small as about 1 mm on a side, and as large as 0.5 m in diameter and 1.5 m tall. Applications in petrology and structural geology include measuring crystal sizes and locations to identify mechanisms governing the kinetics of metamorphic reactions; visualizing relationships between alteration zones and abundant macrodiamonds in Siberian eclogites to elucidate metasomatic processes in the mantle; characterizing morphologies of spiral inclusion trails in garnet to test hypotheses of porphyroblast rotation during growth; measuring vesicle size distributions in basaltic flows for determination of elevation at the time of eruption to constrain timing and rates of continental uplift; analysis of the geometry, connectivity, and tortuosity of migmatite leucosomes to define the topology of melt flow paths, for numerical

  15. Comprometimento pulmonar nas leucemias: avaliação por tomografia computadorizada de alta resolução Pulmonary leukemic involvement: high-resolution computed tomography evaluation

    Directory of Open Access Journals (Sweden)

    Ana Paola de Oliveira

    2004-12-01

    Full Text Available OBJETIVO: Avaliar o papel da tomografia computadorizada de alta resolução (TCAR no estudo de pacientes com leucemia e sintomas pulmonares, analisar os principais padrões encontrados e definir sua etiologia. MATERIAIS E MÉTODOS: Foi feito estudo retrospectivo das TCAR de 15 pacientes com diagnóstico confirmado de leucemia, em vigência de sintomas respiratórios. Os exames foram feitos com protocolo de alta resolução espacial, sendo avaliados por dois radiologistas, de forma independente. RESULTADOS: Os principais padrões observados foram: atenuação em vidro fosco (n = 11, consolidação (n = 9, nódulos do espaço aéreo (n = 3, espessamento de septos interlobulares (n = 3, padrão de árvore em brotamento (n = 3 e derrame pleural (n = 3. A infecção pulmonar foi o achado mais comum, observado em 12 pacientes, com a seguinte freqüência: pneumonia bacteriana (n = 6, infecção fúngica (n = 4, tuberculose pulmonar (n = 1 e infecção viral (n = 1. Os outros três pacientes mostraram infiltração leucêmica pleural (n = 1, linfoma (n = 1 e hemorragia pulmonar (n = 1. CONCLUSÃO: Concluiu-se que a TCAR é de grande importância na avaliação de pacientes com leucemia e neutropenia, com o objetivo de sugerir a causa do quadro pulmonar, avaliar a sua extensão e, em alguns casos, orientar procedimentos invasivos.OBJECTIVE: To evaluate the role of high-resolution computed tomography (HRCT in patients with leukemia and pulmonary symptoms, to establish the main patterns and to correlate them with the etiology. MATERIALS AND METHODS: This is a retrospective study of the HRCT of 15 patients with leukemia and pulmonary symptoms. The examinations were performed using a spatial high-resolution protocol and were analyzed by two independent radiologists. RESULTS: The main HRCT patterns found were ground-glass opacity (n=11, consolidation (n=9, airspace nodules (n=3, septal thickening (n=3, tree-in-bud pattern (n=3, and pleural effusion (n=3

  16. The accuracy of noncontrast spiral computerized tomography in detecting lucent renal stones: A case report and literature review

    OpenAIRE

    Adwan, Ayman; Binsaleh, Saleh

    2015-01-01

    Renal stones are one of the most common diseases in the urology field that are easily diagnosed by one of the standard imaging techniques. Noncontrast spiral computerized tomography (CT) can detect up to 95% of the renal, ureteric and bladder stones, especially those with calcium composition, and considered nowadays one of the most accurate methods for detecting undetectable stones by other modalities. We report a case of a 60-year-old female who presented with colicky right flank pain due to...

  17. An Anatomical Study of Maxillary-Zygomatic Complex Using Three-Dimensional Computerized Tomography-Based Zygomatic Implantation

    OpenAIRE

    Xu, Xiangliang; Zhao, Shijie; Liu, Hui; Sun, Zhipeng; Wang, Jianwei; Zhang, Weiguang

    2017-01-01

    Objective. To obtain anatomical data of maxillary-zygomatic complex based on simulating the zygomatic implantation using cadaver heads and three-dimensional computerized tomography (3D-CT). Methods. Simulating zygomatic implantation was performed using seven cadaver heads and 3D-CT images from forty-eight adults. After measuring the maxillary-zygomatic complex, we analyzed the position between the implantation path and the maxillary sinus cavity as well as the distance between the implantatio...

  18. Multidetector computerized tomography urography is more accurate than excretory urography for diagnosing transitional cell carcinoma of the upper urinary tract in adults with hematuria.

    Science.gov (United States)

    Wang, Li-Jen; Wong, Yon-Cheong; Huang, Chen-Chih; Wu, Cheng-Hsien; Hung, Sheng-Che; Chen, Huan-Wu

    2010-01-01

    It is debatable whether traditionally used excretory urography or the recently introduced multidetector computerized tomography urography is more accurate for diagnosing upper urinary tract transitional cell carcinoma. We compared accuracy measures of both methods for diagnosing upper urinary tract transitional cell carcinoma in adult patients with hematuria. We retrospectively analyzed consecutive adult patients with hematuria undergoing excretory urography and multidetector computerized tomography urography before any surgery, intervention or treatment from April 2004 to December 2006 in our hospital. The presence of upper urinary tract transitional cell carcinoma on excretory urography and multidetector computerized tomography urography was reviewed independently by 2 uroradiologists who were blinded to clinical information and other imaging results. Final diagnosis of upper urinary tract transitional cell carcinoma was confirmed by histological results. Measures of the diagnostic accuracy of excretory urography and multidetector computerized tomography urography for upper urinary tract transitional cell carcinoma were calculated and compared with reference to the final diagnosis. Of 34 men and 26 women with hematuria (mean age 60.73 +/- 12.95 years) 19 (31.7%) had a final diagnosis of 24 upper urinary tract transitional cell carcinomas. The sensitivity, specificity and accuracy of excretory urography were 0.750, 0.860 and 0.849, respectively. In contrast, the sensitivity, specificity and accuracy of multidetector computerized tomography urography were 0.958, 1.000 and 0.996, respectively. Overall the area under the receiver operating characteristic curve for multidetector computerized tomography urography was significantly larger than that for excretory urography (0.978 vs 0.815, p = 0.005). Multidetector computerized tomography urography is more sensitive, specific and accurate than excretory urography in the diagnosis of upper urinary tract transitional cell

  19. Feasibility of rigid 3D image registration of high-resolution peripheral quantitative computed tomography images of healing distal radius fractures.

    Science.gov (United States)

    de Jong, Joost J A; Christen, Patrik; Plett, Ryan M; Chapurlat, Roland; Geusens, Piet P; van den Bergh, Joop P W; Müller, Ralph; van Rietbergen, Bert

    2017-01-01

    For accurate analysis of bone formation and resorption during fracture healing, correct registration of follow-up onto baseline image is required. A per-fragment approach could improve alignment compared to standard registration based on the whole fractured region. In this exploratory study, we tested the effect of fragment size and displacement on a per-fragment registration, and compared the results of this per-fragment registration to the results of the standard registration in two stable fractures and one unstable fracture. To test the effect of fragment size and displacement, high-resolution peripheral quantitative computed tomography (HR-pQCT) scans of three unfractured radii were divided into subvolumes. Different displacements in x-, y, or z-direction or rotations around each axis were applied, and each subvolume was registered onto the initial volume to realign it. Next, registration of follow-up onto baseline scan was performed in two stable and one unstable fracture. After coarsely aligning the follow-up onto the baseline scan, a more accurate registration was performed of the whole fracture, i.e. the standard registration, and of each fracture fragment separately, i.e. per-fragment registration. Alignment was checked using overlay images showing baseline, follow-up and overlap between these scans, and by comparing correlation coefficients between the standard and per-fragment registration. Generally, subvolumes as small as 300 mm3 that were displaced up to 0.82 mm in x- or y-, or up to 1.64 mm in z-direction could be realigned correctly. For the fragments of all fractures, correlation coefficients were higher after per-fragment registration compared to standard registration. Most improvement was found in the unstable fracture and one fragment of the unstable fracture did not align correctly. This exploratory study showed that image registration of individual subvolumes, such as fracture fragments, is feasible in both stable and unstable fractures, and

  20. Feasibility of rigid 3D image registration of high-resolution peripheral quantitative computed tomography images of healing distal radius fractures.

    Directory of Open Access Journals (Sweden)

    Joost J A de Jong

    Full Text Available For accurate analysis of bone formation and resorption during fracture healing, correct registration of follow-up onto baseline image is required. A per-fragment approach could improve alignment compared to standard registration based on the whole fractured region. In this exploratory study, we tested the effect of fragment size and displacement on a per-fragment registration, and compared the results of this per-fragment registration to the results of the standard registration in two stable fractures and one unstable fracture. To test the effect of fragment size and displacement, high-resolution peripheral quantitative computed tomography (HR-pQCT scans of three unfractured radii were divided into subvolumes. Different displacements in x-, y, or z-direction or rotations around each axis were applied, and each subvolume was registered onto the initial volume to realign it. Next, registration of follow-up onto baseline scan was performed in two stable and one unstable fracture. After coarsely aligning the follow-up onto the baseline scan, a more accurate registration was performed of the whole fracture, i.e. the standard registration, and of each fracture fragment separately, i.e. per-fragment registration. Alignment was checked using overlay images showing baseline, follow-up and overlap between these scans, and by comparing correlation coefficients between the standard and per-fragment registration. Generally, subvolumes as small as 300 mm3 that were displaced up to 0.82 mm in x- or y-, or up to 1.64 mm in z-direction could be realigned correctly. For the fragments of all fractures, correlation coefficients were higher after per-fragment registration compared to standard registration. Most improvement was found in the unstable fracture and one fragment of the unstable fracture did not align correctly. This exploratory study showed that image registration of individual subvolumes, such as fracture fragments, is feasible in both stable and

  1. Investigating the architecture of the Paganica Fault (2009 Mw 6.1 earthquake, central Italy) by integrating high-resolution multiscale refraction tomography and detailed geological mapping

    Science.gov (United States)

    Villani, F.; Improta, L.; Pucci, S.; Civico, R.; Bruno, P. P. G.; Pantosti, D.

    2017-01-01

    We present a 2-D subsurface image of the Paganica Fault from a high-resolution refraction tomography and detailed geological investigation carried out across part of the northwestern segment of the 20-km-long Paganica-San Demetrio fault-system, and which was responsible of the 2009 April 6 Mw 6.1 L'Aquila earthquake (central Italy). We acquired two seismic profiles crossing the Paganica basin with a dense-wide aperture configuration. More than 30 000 P wave first-arrival traveltimes were input to a non-linear tomographic inversion. The obtained 250-300 m deep 2-D Vp images illuminate the shallow portion of the Paganica Fault, and depict additional unreported splays defining a complex half-graben structure. We interpret local thickening of low-Vp (<2400 m s-1) and intermediate-Vp (2600-3400 m s-1) regions as syn-tectonic clastic wedges above a high-Vp (3800-5000 m s-1) carbonate basement. These results are condensed in a 4.2-km-long section across the Paganica basin, clearly indicating that the Paganica Fault is a mature normal fault cutting the whole upper ˜10 km of the crust. We evaluate a minimum cumulative net displacement of 650 ± 90 m and a total heave of 530 ± 65 m accomplished by the Paganica Fault, respectively. In the conservative hypothesis that the extension started during the Gelasian (1.80-2.59 Ma), we obtain a minimum long-term slip-rate of 0.30 ± 0.07 mm yr-1 and an extension-rate of 0.25 ± 0.06 mm yr-1, respectively. Considering the regional averaged extensional field of ˜1 mm yr-1 obtained from geodetic and geological analyses at 104 yr timescale, we infer that the Paganica Fault accounts for ˜20 per cent of the NE-extension affecting this zone of the central Apennines axis due to the concurrent activity of other parallel normal fault-systems nearby (e.g. the Liri, Velino-Magnola, L'Aquila-Celano and Gran Sasso fault-systems).

  2. A Critical Comparison Between Two Scanning Protocols of High-Resolution Peripheral Quantitative Computed Tomography at the Distal Radius in Adolescents.

    Science.gov (United States)

    Cheuk, Ka-Yee; Tam, Elisa Man-Shan; Yu, Fiona Wai-Ping; Yip, Benjamin Hon-Kei; Hung, Vivian Wing-Yin; Wang, Xiaofang; Ghasem-Zadeh, Ali; Zhu, Tracy Y; Qin, Ling; Cheng, Jack Chun-Yiu; Lam, Tsz-Ping

    2016-01-01

    High-resolution peripheral quantitative computed tomography (HR-pQCT) is a unique technology for assessing bone mineral density and bone microarchitecture. Currently, no universally accepted protocol for selecting the region of interest (ROI) at the distal radius has been established for growing subjects. This study aimed (1) to investigate the differences in HR-pQCT measurements of 2 different ROI protocols applied to the distal radius of healthy adolescents and (2) to identify the least common area of ROI (the least common ROI) between the protocols. Twenty-six boys and 26 girls aged between 13 and 16 yr old were recruited. Nondominant distal radius was scanned by 2 HR-pQCT protocols, namely, the "5-mm protocol," where the distal end of ROI started at 5 mm proximal to a reference line, and the "4% protocol," where the ROI started at 4% of the ulnar length proximal to another reference line. The least common ROI between the 2 protocols was identified and the slice numbering within the common ROI was determined. Bland-Altman plots were used to check the agreement of the least common ROIs between the 2 protocols. Paired t-test and Wilcoxon signed-rank test were used for analysis. In boys, significant differences between protocols were found in most parameters with the maximum difference observed in the cortical area (25.0%, p only for total volumetric bone mineral density (3.6%, p = 0.032). The number of slices in the least common ROI was 66 (60.0%) and 57 (51.8%) in boys and girls, respectively. Good agreements on all HR-pQCT parameters from the least common ROI between the 2 protocols were found. Significant differences in bone parameters were noted between the 2 protocols. When comparing the 2 protocols, observed gender differences could reflect the differences in skeletal growth at the peripubertal period between genders. Least common ROI could be useful for cross-center comparisons and when merging datasets from different centers. Copyright © 2016

  3. High-resolution and high sensitivity mesoscopic fluorescence tomography based on de-scanning EMCCD: System design and thick tissue imaging applications

    Science.gov (United States)

    Ozturk, Mehmet Saadeddin

    showcased by applying it to the longitudinal assessment of Ink-Jet Bio-Printed tumor models. This preliminary investigation focuses on monitoring four patient-derived glioblastoma multiforme (GBM) spheroids within their bioreactor for up to 70 days and following their volume change prior to and after exposure to a cytotoxic drug. Overall, our studies indicate that 2GMFMT is a powerful technique for in-vitro and in-vivo thick tissue molecular imaging applications due to its high resolution, fast tomographic imaging capability, and high sensitivity.

  4. CARCINOMA BRONQUÍOLO-ALVEOLAR: ASPECTOS NA TOMOGRAFIA COMPUTADORIZADA DE ALTA RESOLUÇÃO Bronchioloalveolar carcinoma: aspects in high-resolution computed tomography

    Directory of Open Access Journals (Sweden)

    Luiza Beatriz Melo Moreira

    2002-01-01

    Full Text Available O carcinoma bronquíolo-alveolar é um tipo de carcinoma broncogênico de crescimento insidioso, que surge nas paredes das vias aéreas distais e se dissemina utilizando o septo alveolar como um estroma, preservando a arquitetura pulmonar. Neste trabalho foram analisadas as tomografias computadorizadas de alta resolução de 17 pacientes com carcinoma bronquíolo-alveolar. Ao contrário do relatado na literatura, foram observados predomínio no sexo masculino (71% e maior freqüência da associação das formas de consolidação e multinodular (53% em relação à forma nodular solitária (12%, multinodular (12% e de consolidação (23%. Os aspectos mais encontrados foram: áreas de consolidação (76%, broncograma aéreo (71%, áreas de baixa atenuação provavelmente devidas à presença de muco (60%, espessamento de septos interlobulares, opacidades em vidro fosco e nódulos confluentes (54% cada, e pavimentação em mosaico (36%. Os nódulos cavitados, a atelectasia, o sinal do halo e o aspecto de "árvore em brotamento" foram observados em apenas um caso cada.Bronchioloalveolar carcinoma is a bronchogenic carcinoma that presents an insidious growth, arises from the walls of the distal air spaces and spreads using the alveolar septa as a stroma, preserving the lung architecture. In this work we analyze the high-resolution computed tomography of 17 patients with bronchioloalveolar carcinoma. Conversely to the data presented in the literature, male preponderance (71% and a higher frequency of association between multinodular and consolidation patterns (53% in comparison to single nodular (12%, multinodular (12% and consolidation (23% patterns were observed. The most common findings were: consolidation areas (76%, air bronchogram (71%, low attenuation areas (60%, thickening of interlobular septa, ground-glass attenuation and confluent nodules (54% each, and crazy paving pattern (36%. Cavitated nodules, atelectasis, halo sign and "tree in bud

  5. Correlations between computerized tomography of the head and motor developmental disturbances of children with cerebral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y.H. (Nagasaki Univ. (Japan). School of Medicine)

    1981-01-01

    Two hundred and eighty-two children with cerebral palsy (C.P.) and thirty-seven normal children were studied by computerized tomography (C.T.) of the head for finding out the correlations between the organic damage of the brain and the motor developmental disturbance. The abnormal findings of C.T. were: enlargement of the ventricular system, high density area, low density area and porencephalus, enlargement of the sulcus and anomaly of the medial structure. Enlargement of the ventricular system seemed to have correlation with spasticity; the portion and the extent of the enlargement corresponded to the affected extremities and the severity of the spasticity. Children of other types also showed various abnormal C.T. findings but, in general, less than that of spastic types. The prognosis of the motor development of C.P. children cannot be predicted by serial C.T. examinations strictly, because early treatment could cause improvement to that of these children. However, it is of worthy notice that C.T. is an effective method of helping to diagnose the motor developmental disturbance in earlier childhood.

  6. The approximate inversion as a reconstruction method in X-ray computerized tomography

    CERN Document Server

    Dietz, R L

    1999-01-01

    The mathematical model of the X-ray computerized tomography will be developed in the first chapter, the approximate inversion will be introduced, and the Radon Transform will be used as an example to demonstrate calculation of a reconstruction cone. In the second chapter, a reconstruction method for the parallel geometry is discussed, leading to derivation of the method for a fan-beam geometry. The approximate inversion calculated for the limited-angle case is presented as an example of incomplete data problems. As with complete data problems, numerical examples are given and the method is compared with existing other methods. 3D reconstruction is the topic of the third chapter. Although of no relevance in practice, a parallel geometry will be examined. No problems are encountered in transferring the reconstruction cone to the cone beam geometry, but only for a scanning curve which also is of no relevance in practice. A further reconstruction method is presented for curves fulfilling the so-called Tuy conditi...

  7. A modified conjugate gradient method based on the Tikhonov system for computerized tomography (CT).

    Science.gov (United States)

    Wang, Qi; Wang, Huaxiang

    2011-04-01

    During the past few decades, computerized tomography (CT) was widely used for non-destructive testing (NDT) and non-destructive examination (NDE) in the industrial area because of its characteristics of non-invasiveness and visibility. Recently, CT technology has been applied to multi-phase flow measurement. Using the principle of radiation attenuation measurements along different directions through the investigated object with a special reconstruction algorithm, cross-sectional information of the scanned object can be worked out. It is a typical inverse problem and has always been a challenge for its nonlinearity and ill-conditions. The Tikhonov regulation method is widely used for similar ill-posed problems. However, the conventional Tikhonov method does not provide reconstructions with qualities good enough, the relative errors between the reconstructed images and the real distribution should be further reduced. In this paper, a modified conjugate gradient (CG) method is applied to a Tikhonov system (MCGT method) for reconstructing CT images. The computational load is dominated by the number of independent measurements m, and a preconditioner is imported to lower the condition number of the Tikhonov system. Both simulation and experiment results indicate that the proposed method can reduce the computational time and improve the quality of image reconstruction. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.

  8. Numerical Modeling of Jointed Rock Under Compressive Loading Using X-ray Computerized Tomography

    Science.gov (United States)

    Yu, Qinglei; Yang, Shengqi; Ranjith, P. G.; Zhu, Wancheng; Yang, Tianhong

    2016-03-01

    As jointed rocks consist of joints embedded within intact rock blocks, the presence and geometrical fabric of joints have a great influence on the mechanical behavior of rock. With consideration of the actual spatial shape of joints, a numerical model is proposed to investigate the fracture evolution mechanism of jointed rocks. In the proposed model, computerized tomography (CT) scanning is first used to capture the microstructure of a jointed sandstone specimen, which is artificially fabricated by loading the intact sample until the residual strength, and then digital image processing (DIP) techniques are applied to characterize the geometrical fabric of joints from the CT images. A simple vectorization method is used to convert the microstructure based on a cross-sectional image into a layer of 3-D vectorized microstructure and the overall 3-D model of the jointed sandstone including the real spatial shape of the joints is established by stacking the layers in a specific sequence. The 3-D model is then integrated into a well-established code [three-dimensional Rock Failure Process Analysis, (RFPA3D)]. Using the proposed model, a uniaxial compression test of the jointed sandstone is simulated. The results show that the presence of joints can produce tensile stress zones surrounding them, which result in the fracture of jointed rocks under a relatively small external load. In addition, the spatial shape of the joints has a great influence on the fracture process of jointed rocks.

  9. Intellectual function, activities of daily living and computerized tomography of the brain in geriatric demented patients

    Energy Technology Data Exchange (ETDEWEB)

    Omura, Fumiaki; Ogura, Chikara; Kishimoto, Akira; Okubo, Masayo; Imamoto, Atsushi (Tottori Univ., Yonago (Japan). School of Medicine); Tsuchie, Harutaka; Sugihara, Kanichiro; Fujii, Shozo

    1984-09-01

    Thirty eight patients of geriatric dementia (mean age 74.9 years) were examined by computerized tomography (CT) and their intellectual functions and activities of daily living (ADL) were evaluated. CT was evaluated by both visual assessment method and direct measuring method. Intellectual function was evaluated by Jikei University dementia rating scale. ADL was evaluated by both Hasegawa's rating scale and Sengoku's rating scale. Results were as follows: significant influence by age was observed in intellectual functions and ADL of subjects above 75 years old. There were good correlations between the higher intellectual function, the better grooming and hygiene, and less needs of nursing care. The severe brain atrophy evaluated by the visual assessment method was correlated with the depressed level of intellectual function. When brain atrophy is mild despite high degree of dementia, reexamination should be made to explore somatic diseases inducing depression of mental activity. It also should be noted that sex and age difference is important in studying geriatric patients.

  10. Prospective comparison of computerized tomography and excretory urography in the initial evaluation of asymptomatic microhematuria.

    Science.gov (United States)

    Gray Sears, Christine L; Ward, John F; Sears, Stephen T; Puckett, Michael F; Kane, Christopher J; Amling, Christopher L

    2002-12-01

    The ideal imaging study for evaluation of the upper urinary tract in patients with microhematuria has been debated. We prospectively compared the diagnostic yield of computerized tomography (CT) to excretory urography (IVP) in the initial evaluation of asymptomatic microhematuria. Between December 1998 and June 2001, 115 patients presenting with asymptomatic microhematuria underwent CT and IVP before cystoscopy. Helical CT images with 5 mm. adrenal and kidney slices with and without contrast material were followed by delayed 5 mm. ureteral contrast images through the bladder base. Each CT and IVP was examined by a radiologist who was blinded to the result of the other imaging study. Diagnostic yields of the imaging techniques were compared using the test of 2 proportions and chi-square analysis. Radiographic abnormalities were noted on CT or IVP in 38 patients. Sensitivity was 100% for CT and 60.5% for IVP, and specificity 97.4% for CT and 90.9% for IVP. CT accuracy was 98.3% compared to IVP accuracy which was 80.9% (p <0.001). A total of 40 nonurological diagnoses were made by CT, including 3 abdominal aortic aneurysms and 1 iliac artery aneurysm. No additional diagnoses were made by IVP. Fewer additional radiographic studies were recommended after CT than after IVP. The use of CT in the initial evaluation of asymptomatic microhematuria results in better diagnostic yield. In addition, more nonurological diagnoses can be made and less additional radiography is needed to confirm a diagnosis.

  11. Diagnostic Value of Dual-Source Computerized Tomography Combined with Perfusion Imaging for Peripheral Pulmonary Embolism

    Science.gov (United States)

    Mao, Xijin; Wang, Shanshan; Jiang, Xingyue; Zhang, Lin; Xu, Wenjian

    2016-01-01

    Background Pulmonary embolism has become the third most common cardiovascular disease, which can seriously harm human health. Objectives To investigate the diagnostic value of dual-source computerized tomography (CT) and perfusion imaging for peripheral pulmonary embolism. Patients and Methods Thirty-two patients with suspected pulmonary embolism underwent dual-source CT exams. To compare the ability of pulmonary embolism detection software (PED) with CT pulmonary angiography (CTPA) in determining the presence, numbers, and locations of pulmonary emboli, the subsequent images were reviewed by two radiologists using both imaging modalities. Also, the diagnostic consistency between PED and CTPA images and dual-energy pulmonary perfusion imaging (DEPI) for segmental pulmonary embolism was compared. Results CTPA images revealed 50 (7.81%) segmental and 56 (4.38%) sub-segmental pulmonary embolisms, while the PED images showed 68 (10.63%) segmental and 94 (7.34%) sub-segmental pulmonary embolisms. Thus, the detection rate on PED images for peripheral pulmonary embolism was significantly higher than that of the CTPA images (P pulmonary embolism between PED and CTPA and DEPI (kappa = 0.85). The sensitivity and specificity of DEPI images for the diagnosis of pulmonary embolism were 91.7% and 97.5%, respectively. Conclusion PED software of dual-source CT combined with perfusion imaging can significantly improve the detection rate of peripheral pulmonary embolism. PMID:27703656

  12. Survey radiography and computerized tomography imaging of the thorax in female dogs with mammary tumors

    Directory of Open Access Journals (Sweden)

    Giordano Tatiana

    2010-03-01

    Full Text Available Abstract Background Accurate early diagnosis of lung metastases is important for establishing therapeutic measures. Therefore, the present study aimed to compare survey thoracic radiographs and computerized tomography (CT scans to specifically identify lung metastases in female dogs with mammary tumors. Methods Twenty-one female dogs, weighing 3 to 34 kg and aged from 5 years to 14 years and 10 months, with mammary tumors were studied. In all dogs before the imaging examinations, fine-needle aspiration cytology of the mammary tumors was performed to confirm the diagnosis. Three-view thoracic radiographs were accomplished: right lateral, left lateral and ventrodorsal views. Sequential transverse images of the thorax were acquired on a spiral Scanner, before and after intravenous bolus injection of nonionic iodine contrast. Soft-tissue and lung windows were applied. All the mammary tumors were surgically removed and examined histologically. Results The correlation between the cytological and histological results regarding presence of malignancy was observed in only 17 cases. In radiographic examinations, no dog displayed signs of lung metastases or thorax chest lesions. CT detected lung metastasis in two cases, while small areas of lung atelectasis located peripherally were found in 28.57% of the dogs. Conclusion In this study population, spiral CT showed higher sensitivity than chest radiographies to detect lung metastasis; this indicates that CT should be performed on all female dogs with malignant mammary tumors.

  13. The detection accuracies for proximal caries by cone-beam computerized tomography, film, and phosphor plates.

    Science.gov (United States)

    Zhang, Zhi-ling; Qu, Xing-min; Li, Gang; Zhang, Zu-yan; Ma, Xu-chen

    2011-01-01

    To evaluate the accuracy of cone-beam computerized tomography (CBCT) for the detection of noncavitated proximal caries and to compare the detection accuracies of 2 CBCT imaging systems with those based on plain-film radiographs and phosphor-plate images. Test radiographs of 39 noncavitated unrestored human permanent teeth were obtained with film, phosphor-plate, ProMax 3D, and Kodak 9000 3D imaging systems. Seven observers used a 5-level scale to evaluate test images for the presence of proximal caries. With histologic examination serving as the reference standard, observer performances were assessed with receiver operating characteristic (ROC) curves, and the areas under the ROC curves (A(z) values) for the observers, and modalities were analyzed with a repeated-measures analysis of variance. The mean A(z) values for film, phosphor plates, ProMax 3D, and Kodak 9000 3D imaging systems were 0.541, 0.523, 0.528, and 0.525, respectively (P = .763). For detecting subtle noncavitated proximal caries, the detection accuracy with the CBCT images was little better than chance performance and was similar to that with phosphor plate- and film-based intraoral images. Copyright © 2011 Mosby, Inc. All rights reserved.

  14. Morphometric analysis of the cervical spine of Indian population by using computerized tomography

    Directory of Open Access Journals (Sweden)

    Partha Sarathi Banerjee

    2012-08-01

    Full Text Available The purpose of the present study was to measure the surgically important morphological parameters of cervical spine region of a representative sample of Indian population from the images obtained through computerized tomography (CT. Another purpose has been to compare the computed statistical mean, standard deviation and range of variation of these data with those of other Asian population and also European/American populations. With that aim, ninety five (95 CT scan data of Indian people (73 for male patients and 22 for female patients pertaining to undeformed normal cervical spine has been collected from an Indian hospital. From these, 15 important morphological parameters have been measured. These values have been tabulated and their mean, standard deviation and range of variation have been computed. It has been found that pedicle dimensions of Indian people are smaller at almost all vertebra levels as compared to Caucasian people. Pedicle axis length for Indian people are found to be smaller at C3, C4 and C5 levels than those for other Asian people including Chinese people, but it is bigger at C6 and C7 levels. Indian people have longer measurements of pedicle length + lateral mass on an average than their other Asian counterparts at C5, C6 and C7 levels, but shorter measurements at C3 and C4 levels. The results of the present work may help in better understanding of morphological parameters of cervical spine region of Indian population. It may be further useful in designing spinal implants which would be biomechanically compatible to the anatomy of Indian people.

  15. Is computerized tomography useful in identifying abdominal catastrophes in patients presenting with peritonitis?

    Science.gov (United States)

    Yehia, Maha; de Zoysa, Janak R; Collins, John F

    2008-01-01

    Peritonitis is a significant source of morbidity and mortality in patients on peritoneal dialysis (PD). Symptoms may persist, requiring an emergency laparotomy. Although increasingly used, we find that, in PD patients, abdominal computerized tomography (CT) is ineffective in determining significant pathology. This study was undertaken to assess the diagnostic utility of CT for the identification of intra-abdominal collections in PD patients presenting with peritonitis. A retrospective chart review was undertaken of all patients that underwent abdominal CT scanning in the context of severe PD peritonitis in the past 2 years. All of these patients had at least one CT scan preoperatively. 133 patients presented with PD peritonitis; 19 patients had a contrast CT procedure (12 females, 7 males). Average age was 59.2 years; mean duration on PD was 43.8 months. 13 of 19 patients had gram-negative bacillary peritonitis, 6 of whom had polymicrobial peritonitis; 4 patients had fungal peritonitis and 2 had Staphylococcus aureus peritonitis. 26 CT scans were done in 19 patients an average of 10 days after presentation. 21 of 26 scans revealed no collections of surgical interest. 12 laparotomies were performed, with an average delay of 10.4 days from presentation to laparotomy. Of the 12 laparotomies, 6 found a drainable collection not seen on CT. Seven of the 19 patients died (37%) and no patient was able to return to PD. PD patients requiring emergency laparotomy following PD peritonitis have a high mortality rate. A negative abdominal CT in the setting of ongoing symptoms should not be taken as reassuring, nor should it delay proceeding to emergency laparotomy.

  16. A computerized tomography study of the morphological interrelationship between the temporal bones and the craniofacial complex

    Science.gov (United States)

    Costa, Helder Nunes; Slavicek, Rudolf; Sato, Sadao

    2012-01-01

    The hypothesis that the temporal bones are at the center of the dynamics of the craniofacial complex, directly influencing facial morphology, has been put forward long ago. This study examines the role of the spatial positioning of temporal bones (frontal and sagittal inclination) in terms of influencing overall facial morphology. Several 3D linear, angular and orthogonal measurements obtained through computerized analysis of virtual models of 163 modern human skulls reconstructed from cone-beam computed tomography images were analyzed and correlated. Additionally, the sample was divided into two subgroups based on the median value of temporal bone sagittal inclination [anterior rotation group (n = 82); posterior rotation group (n = 81)], and differences between groups evaluated. Correlation coefficients showed that sagittal inclination of the temporal bone was significantly (P < 0.01) related to midline flexion, transversal width and anterior–posterior length of the basicranium, to the anterior–posterior positioning of the mandible and maxilla, and posterior midfacial height. Frontal inclination of the temporal bone was significantly related (P < 0.01) to basicranium anterior–posterior and transversal dimensions, and to posterior midfacial height. In comparison with the posterior rotation group, the anterior rotation group presented a less flexed and anterior–posteriorly longer cranial base, a narrower skull, porion and the articular eminence located more superiorly and posteriorly, a shorter posterior midfacial height, the palatal plane rotated clockwise, a more retrognathic maxilla and mandible, and the upper posterior occlusal plane more inclined and posteriorly located. The results suggest that differences in craniofacial morphology are highly integrated with differences in the positional relationship of the temporal bones. The sagittal inclination of the temporal bone seems to have a greater impact on the 3D morphology of the craniofacial complex than

  17. New onset seizures: Etiology and co-relation of clinical features with computerized tomography and electroencephalography

    Directory of Open Access Journals (Sweden)

    V Muralidhar

    2015-01-01

    Full Text Available Aims and Objective: To establish whether the reported episode was a seizure, to determine the cause of seizure by identifying the risk factors, lab, radiological and electroencephalography (EEG evaluation to determine any underlying structural abnormality and to decide whether anti-epileptics therapy is essential. Settings and Design: This was a descriptive study. Materials and Methods: (1 Source of data - All the patients with inclusion criteria attending to the medicine outpatient department (OPD/wards. Sample size = 50 cases. (2 Study subjects - Inclusion criteria: All patients >15 years age group presenting in medicine OPD/wards with the first episode of seizure. Exclusion criteria: Seizures on treatment and head injury. Methods of Collection of Data: Each patient was subjected to the detailed evaluation including history, precipitating factors, and symptomatology recorded accordingly. History of hypertension, diabetes mellitus, tuberculosis (TB was enquired into. Family history of epilepsy, TB was recorded. Complete clinical evaluation and thorough investigations-complete blood count, urine examination, blood urea nitrogen, random blood sugar, chest X-ray, computerized tomography (CT scan and EEG were done for all patients in the inclusion criteria. Anti-epileptics were started if either CT/EEG was abnormal, rest of the patients were not given anti-epileptics. Follow-up was done for 6 months, and any recurrence of seizures was noted. The data collected from cases in the inclusion criteria were recorded in a Master chart. Data analysis was done using appropriate statistical tests and graphs. Results and Conclusions: Peak incidence of new onset seizure was second to third decade (25 cases; 50%, max cases <25 years, male: Female ratio of 2.12:1, duration of seizure <5 min (30 cases; 60%, evidence of TB = 6 cases (12%, alcohol intake = 5 cases (10%, developmental delay = 3 cases (6%, family history = 3 cases (6%, old cerebro-vascular accident

  18. Computerized tomography attenuation values can be used to differentiate hydronephrosis from pyonephrosis.

    Science.gov (United States)

    Yuruk, Emrah; Tuken, Murat; Sulejman, Suhejb; Colakerol, Aykut; Serefoglu, Ege Can; Sarica, Kemal; Muslumanoglu, Ahmet Yaser

    2017-03-01

    To determine the diagnostic value of computerized tomography (CT) in differentiating pyonephrosis from hydronephrosis on the basis of attenuation values (Hounsfield unit-HU). Data of the patients with grades 1-3 hydronephrosis on abdominopelvic CT, who underwent nephrostomy tube placement for decompression of the collecting system, were retrospectively analyzed. Patient demographics and CT findings were recorded along with the first access urine culture results. Three physicians calculated the surface areas and the attenuation values of the dilated collecting systems using the system software. Mean HU of pyonephrosis and hydronephrosis cases was compared. A total of 105 patients with the mean age of 47.7 ± 15.5 (range 20-80) were included. The interclass correlation coefficient of three physicians was 0.981 for HU measurement and 0.999 for calculation of collecting system surface area. Of the patients, 47 (44.8 %) had pyonephrosis. Mean surface areas of the collecting system were similar in patients with pyonephrosis and hydronephrosis (1481.13 ± 1562.94 vs. 1612.94 ± 2261.4 mm2, p = 0.735). Urine cultures were positive in all patients with pyonephrosis, whereas 12.7 % of hydronephrosis cases had bacterial in first access urine culture. The HU of the patients with pyonephrosis was significantly higher that that of patients with hydronephrosis (13.51 ± 13.29 vs. 4.67 ± 5.37, p = 0.0001). Having a HU of 9.21 or over diagnosed pyonephrosis accurately with 65.96 % sensitivity and 87.93 % specificity. Measuring attenuation values of the collecting system may be useful to differentiate pyonephrosis from hydronephrosis. Diagnosing pyonephrosis accurately may avoid septic complications.

  19. High-resolution computed tomography in chronic diffuse diseases of the pulmonary parenchyma. La tomodensitometrie haute resolution dans les maladies chroniques diffuses du parenchyme pulmonaire

    Energy Technology Data Exchange (ETDEWEB)

    Brauner, M. (Hopital Avicenne, 93 Bobigny (FR))

    1990-01-01

    High-resolution CT is a new method for the study of the pulmonary parenchyma which has several merits. It allows screening subradiographic lesions of the lungs, accurately locating the lesions, quantifying them, suggesting the etiological diagnosis, contributing in the assessment of the activity of the disease and following its evolution. A new semiology is being developed.

  20. High Resolution Elevation Contours

    Data.gov (United States)

    Minnesota Department of Natural Resources — This dataset contains contours generated from high resolution data sources such as LiDAR. Generally speaking this data is 2 foot or less contour interval.

  1. The accuracy of noncontrast spiral computerized tomography in detecting lucent renal stones: A case report and literature review

    Directory of Open Access Journals (Sweden)

    Ayman Adwan

    2015-01-01

    Full Text Available Renal stones are one of the most common diseases in the urology field that are easily diagnosed by one of the standard imaging techniques. Noncontrast spiral computerized tomography (CT can detect up to 95% of the renal, ureteric and bladder stones, especially those with calcium composition, and considered nowadays one of the most accurate methods for detecting undetectable stones by other modalities. We report a case of a 60-year-old female who presented with colicky right flank pain due to large calcium oxalate renal stone that is undetected by standard imaging technique including spiral CT scan. Uretroscopy diagnosed and ultimately treat this patient problem.

  2. The accuracy of noncontrast spiral computerized tomography in detecting lucent renal stones: A case report and literature review.

    Science.gov (United States)

    Adwan, Ayman; Binsaleh, Saleh

    2015-01-01

    Renal stones are one of the most common diseases in the urology field that are easily diagnosed by one of the standard imaging techniques. Noncontrast spiral computerized tomography (CT) can detect up to 95% of the renal, ureteric and bladder stones, especially those with calcium composition, and considered nowadays one of the most accurate methods for detecting undetectable stones by other modalities. We report a case of a 60-year-old female who presented with colicky right flank pain due to large calcium oxalate renal stone that is undetected by standard imaging technique including spiral CT scan. Uretroscopy diagnosed and ultimately treat this patient problem.

  3. Serial measurement of regional cerebral blood flow in patients with SAH using 133Xe inhalation and emission computerized tomography

    DEFF Research Database (Denmark)

    Mickey, B; Vorstrup, S; Voldby, Bo

    1984-01-01

    defined regional flow decrease in the vascular territories of the anterior or middle cerebral arteries. Severe vasospasm was noted in three of these patients in whom arteriography was performed in the 2nd week post SAH. Diffuse bihemispheric CBF decreases were noted later in the course of delayed......A noninvasive three-dimensional method for measuring cerebral blood flow (CBF), xenon-133 inhalation and emission computerized tomography, was used to investigate the CBF changes accompanying delayed neurological deterioration following subarachnoid hemorrhage (SAH). A total of 67 measurements were...

  4. Calculating the number of shock waves, expulsion time, and optimum stone parameters based on noncontrast computerized tomography characteristics.

    Science.gov (United States)

    Foda, Khaled; Abdeldaeim, Hussein; Youssif, Mohamed; Assem, Akram

    2013-11-01

    To define the parameters that accompanied a successful extracorporeal shock wave lithotripsy (ESWL), namely the number of shock waves (SWs), expulsion time (ET), mean stone density (MSD), and the skin-to-stone distance (SSD). A total of 368 patients diagnosed with renal calculi using noncontrast computerized tomography had their MSD, diameter, and SSD recorded. All patients were treated using a Siemens lithotripter. ESWL success meant a stone-free status or presence of residual fragments 934 HUs and SSD >99 mm. The required number of SWs and the expected ET can be anticipated. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Prediction of coma and anisocoria based on computerized tomography findings in patients with supratentorial intracerebral hemorrhage.

    Science.gov (United States)

    Song, Zhi; Zheng, Wen; Zhu, Haixia; Chen, Yiwei; Fan, Xuejun; Hou, Deren; Deng, Hao

    2012-07-01

    Coma and anisocoria are the two common signs of a crucial state of neurological dysfunction. The ability to forecast the occurrence of these conditions would help clinicians make clinical risk assessments and decisions. From October 2006 to September 2008, 118 patients with supratentorial intracerebral hemorrhage (SICH) were enrolled in this retrospective investigation. Patients were distributed into 3 groups according to occurrence of the signs of coma and/or anisocoria in the observation unit during a 30-day period. Group 1 included 52 patients who had normal or impaired consciousness, group 2 included 27 patients who had coma with no anisocoria and group 3 consisted of 39 patients who had coma with anisocoria. The clinical characteristics and parameters on computerized tomography (CT) findings were compared using univariate analysis to determine the factors that were related to the level of consciousness. Logistic regression models established the predictive equations for coma and anisocoria. Univariate analysis revealed that hematoma volume, the score of intraventricular hemorrhage (IVH score) and the amplitude of midline shift were the factors related to coma and anisocoria. Mean hematoma volume was 24.0 ± 13.0 ml, 53.6 ± 12.6 ml and 80.5 ± 24.6 ml, the mean amplitudes of midline shift were 1.3 ± 2.0 mm, 5.9 ± 4.9 mm and 10.1 ± 5.5 mm, and the mean IVH score was 0.8 ± 1.3, 3.3 ± 3.3 and 5.9 ± 3.4 in groups 1, 2 and 3, respectively. Multivariate analysis showed that hematoma volume and IVH score were independent prognostic factors for coma and anisocoria. The predictive equations for coma and anisocoria were LogitP = 0.279X(HV) + 0.521X(IVH)-18.164 and LogitP = 0.125X(HV)+0.326X(IVH)-6.864, respectively. Hematoma volume and IVH score were the independent prognostic factors for coma and anisocoria. Logistic regression models established the fitted predictive equations, which could help clinicians make clinical risk assessments and decisions. Crown

  6. The role of renal scintigraphy and unenhanced helical computerized tomography in patients with ureterolithiasis.

    Science.gov (United States)

    Lorberboym, M; Kapustin, Z; Elias, S; Nikolov, G; Katz, R

    2000-04-01

    Unenhanced helical computerized tomography (UHCT) has recently evolved as an accurate imaging modality for determination of the presence or absence of ureterolithiasis in patients with acute flank pain. Functional renal scintigraphy is considered the gold standard for urinary tract obstruction. The objective of this study was to correlate the secondary signs of urinary obstruction on UHCT with findings of functional renal scintigraphy. UHCT was performed in 30 patients admitted to the emergency room with acute flank pain. All patients had a calcified urinary stone identified on UHCT. The location of each urinary stone was classified as ureteral or in the ureterovesical junction. The presence of secondary CT signs of ureteral obstruction was determined for each patient. After oral or intravenous hydration, a technetium-99m diethylene triamine penta-acetic acid renal scan was performed in all patients within 12 h of the CT scan. Follow-up delayed scintigraphic images were obtained at 2 h and 24 h in patients with evidence of ureteral obstruction. The sensitivity, specificity and predictive values of each possible combination of CT findings were determined by comparison with the scintigraphic results. The distal ureter was the most common location for a calculus on UHCT, followed in frequency by the ureterovesical junction, proximal ureter and mid-ureter. The renograms showed high-grade, unilateral obstruction in 12 patients, indeterminate scans in five patients and normal renograms in 13 patients. The sensitivities and specificities of individual CT findings ranged from 50% to 75% and from 8% to 69%, respectively. Perinephric stranding gave the highest positive predictive value (PPV) for obstruction (69% including indeterminate renograms). None of the individual CT findings showed a statistically significant correlation with scintigraphic findings. A combination of one or two positive CT findings had a PPV of only 25% for obstruction. A combination of three or four

  7. Are Hepatic Portal Venous System Components Distributed Equally in the Liver? A Multidetector Computerized Tomography Study

    Directory of Open Access Journals (Sweden)

    Bülent Yalçın

    2012-12-01

    Full Text Available Objective: We aimed to evaluate the relationships between the splenic index, right and left hepatic lobe volumes, diameters of splenic vein (SV, superior mesenteric vein (SMV and the portal vein (PV by Multidetector Computerized Tomography (MDCT. We also investigated indirect signs of portal venous flow pattern using these parameters.Material and Methods: Following their contrast thoracoabdominal and abdominal 64-MDCT examinations, the images of 100 cases (61 males and 39 females were evaluated retrospectively. For each case, the splenic index, total hepatic volume, left and right hepatic volumes were calculated on the post-contrast portal venous phase (50th sec images. Spearman correlation tests were carried out with the purpose of determining the relationships between the variables. Statistical significance level was set at p<0.005.Results: A statistically significant relation was demonstrated between the diameter of the SMV and right hepatic lobe volume (p<0.0001, and according to Pearson’s correlation analysis, a positive correlation of medium strength (r=0.36 was observed. A positive correlation was demonstrated between the diameter of the splenic vein and left hepatic lobe volume (r=0.36. Statistically significant relation between the diameters of the splenic vein and right hepatic lobe was not observed (p=0.62. A strong correlation between the left hepatic lobe volume and the splenic index (r=0.556 was observed.Conclusion: We observed a positive correlation and a significant relation between the diameter of the SMV and the right hepatic lobe, and a relation between the splenic vein and splenic index and both hepatic lobes. We believe that this situation is related to the streamline flow in the portal vein, and as demonstrated in the literature, the flow in the SMV is directed at the right lobe, whereas the splenic vein empties into the liver homogenously. Our study is the first study in the literature performed by multidetector CT

  8. Prediction of differential creatinine clearance in chronically obstructed kidneys by non-contrast helical computerized tomography

    Directory of Open Access Journals (Sweden)

    Ng C.F.

    2004-01-01

    Full Text Available PURPOSE: We investigate the use of non-contrast helical computerized tomography (NCHCT in the measurement of differential renal parenchymal volume as a surrogate for differential creatinine clearance (CrCl for unilateral chronically obstructed kidney. MATERIALS AND METHODS: Patients with unilateral chronically obstructed kidneys with normal contralateral kidneys were enrolled. Ultrasonography (USG of the kidneys was first done with the cortical thickness of the site with the most renal substance in the upper pole, mid-kidney, and lower pole of both kidneys were measured, and the mean cortical thickness of each kidney was calculated. NCHCT was subsequently performed for each patient. The CT images were individually reviewed with the area of renal parenchyma measured for each kidney. Then the volume of the slices was summated to give the renal parenchymal volume of both the obstructed and normal kidneys. Finally, a percutaneous nephrostomy (PCN was inserted to the obstructed kidney, and CrCl of both the obstructed kidney (PCN urine and the normal side (voided urine were measured two 2 after the relief of obstruction. RESULTS: From March 1999 to February 2001, thirty patients were enrolled into the study. Ninety percent of them had ureteral calculi. The differential CrCl of the obstructed kidney (%CrCl was defined as the percentage of CrCl of the obstructed kidney as of the total CrCl, measured 2 weeks after relief of obstruction. The differential renal parenchymal volume of the obstructed kidney (%CTvol was the percentage of renal parenchymal volume as of the total parenchymal volume. The differential USG cortical thickness of the obstructed kidney (%USGcort was the percentage of mean cortical thickness as of the total mean cortical thickness. The Pearson's correlation coefficient (r between %CTvol and %CrCl and that between %USGcort and %CrCl were 0.756 and 0.543 respectively. The regression line was %CrCl = (1.00 x %CTvol - 14.27. The %CTvol

  9. Metabolomics of Breast Cancer Using High-Resolution Magic Angle Spinning Magnetic Resonance Spectroscopy: Correlations with 18F-FDG Positron Emission Tomography-Computed Tomography, Dynamic Contrast-Enhanced and Diffusion-Weighted Imaging MRI.

    Directory of Open Access Journals (Sweden)

    Haesung Yoon

    Full Text Available Our goal in this study was to find correlations between breast cancer metabolites and conventional quantitative imaging parameters using high-resolution magic angle spinning (HR-MAS magnetic resonance spectroscopy (MRS and to find breast cancer subgroups that show high correlations between metabolites and imaging parameters.Between August 2010 and December 2013, we included 53 female patients (mean age 49.6 years; age range 32-75 years with a total of 53 breast lesions assessed by the Breast Imaging Reporting and Data System. They were enrolled under the following criteria: breast lesions larger than 1 cm in diameter which 1 were suspicious for malignancy on mammography or ultrasound (US, 2 were pathologically confirmed to be breast cancer with US-guided core-needle biopsy (CNB 3 underwent 3 Tesla MRI with dynamic contrast-enhanced (DCE and diffusion-weighted imaging (DWI and positron emission tomography-computed tomography (PET-CT, and 4 had an attainable immunohistochemistry profile from CNB. We acquired spectral data by HR-MAS MRS with CNB specimens and expressed the data as relative metabolite concentrations. We compared the metabolites with the signal enhancement ratio (SER, maximum standardized FDG uptake value (SUV max, apparent diffusion coefficient (ADC, and histopathologic prognostic factors for correlation. We calculated Spearman correlations and performed a partial least squares-discriminant analysis (PLS-DA to further classify patient groups into subgroups to find correlation differences between HR-MAS spectroscopic values and conventional imaging parameters.In a multivariate analysis, the PLS-DA models built with HR-MAS MRS metabolic profiles showed visible discrimination between high and low SER, SUV, and ADC. In luminal subtype breast cancer, compared to all cases, high SER, ADV, and SUV were more closely clustered by visual assessment. Multiple metabolites were correlated with SER and SUV in all cases. Multiple metabolites

  10. High-resolution computed tomography evaluation of the bronchial lumen to vertebral body diameter and pulmonary artery to vertebral body diameter ratios in anesthetized ventilated normal cats.

    Science.gov (United States)

    Lee-Fowler, Tekla M; Cole, Robert C; Dillon, A Ray; Tillson, D Michael; Garbarino, Rachel; Barney, Sharron

    2017-10-01

    Objectives Bronchial lumen to pulmonary artery diameter (BA) ratio has been utilized to investigate pulmonary pathology on high-resolution CT images. Diseases affecting both the bronchi and pulmonary arteries render the BA ratio less useful. The purpose of the study was to establish bronchial lumen diameter to vertebral body diameter (BV) and pulmonary artery diameter to vertebral body diameter (AV) ratios in normal cats. Methods Using high-resolution CT images, 16 sets of measurements (sixth thoracic vertebral body [mid-body], each lobar bronchi and companion pulmonary artery diameter) were acquired from young adult female cats and 41 sets from pubertal female cats. Results Young adult and pubertal cat BV ratios were not statistically different from each other in any lung lobe. Significant differences between individual lung lobe BV ratios were noted on combined age group analysis. Caudal lung lobe AV ratios were significantly different between young adult and pubertal cats. All other lung lobe AV ratios were not significantly different. Caudal lung lobe AV ratios were significantly different from all other lung lobes but not from each other in both the young adult and pubertal cats. Conclusions and relevance BV ratio reference intervals determined for individual lung lobes could be applied to both young adult and pubertal cats. Separate AV ratios for individual lung lobes would be required for young adult and pubertal cats. These ratios should allow more accurate evaluation of cats with concurrent bronchial and pulmonary arterial disease.

  11. Influence of Respiratory Gating, Image Filtering, and Animal Positioning on High-Resolution Electrocardiography-Gated Murine Cardiac Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chao Wu

    2015-01-01

    Full Text Available Cardiac parameters obtained from single-photon emission computed tomographic (SPECT images can be affected by respiratory motion, image filtering, and animal positioning. We investigated the influence of these factors on ultra-high-resolution murine myocardial perfusion SPECT. Five mice were injected with 99m technetium (99mTc-tetrofosmin, and each was scanned in supine and prone positions in a U-SPECT-II scanner with respiratory and electrocardiographic (ECG gating. ECG-gated SPECT images were created without applying respiratory motion correction or with two different respiratory motion correction strategies. The images were filtered with a range of three-dimensional gaussian kernels, after which end-diastolic volumes (EDVs, end-systolic volumes (ESVs, and left ventricular ejection fractions were calculated. No significant differences in the measured cardiac parameters were detected when any strategy to reduce or correct for respiratory motion was applied, whereas big differences (> 5% in EDV and ESV were found with regard to different positioning of animals. A linear relationship (p < .001 was found between the EDV or ESV and the kernel size of the gaussian filter. In short, respiratory gating did not significantly affect the cardiac parameters of mice obtained with ultra-high-resolution SPECT, whereas the position of the animals and the image filters should be the same in a comparative study with multiple scans to avoid systematic differences in measured cardiac parameters.

  12. In vivo determination of urinary stone composition using dual energy computerized tomography with advanced post-acquisition processing.

    Science.gov (United States)

    Zilberman, D E; Ferrandino, M N; Preminger, G M; Paulson, E K; Lipkin, M E; Boll, D T

    2010-12-01

    We assessed whether dual energy computerized tomography with advanced post-image processing can accurately differentiate urinary calculi composition in vivo. A total of 25 patients scheduled to undergo ureteroscopic/percutaneous nephrolithotomy were prospectively identified. Dual energy computerized tomography was performed using 64-slice multidetector computerized tomography. Novel post-processing (DECTSlope) used pixel by pixel analyses to generate data sets grayscale encoding ratios of relative differences in attenuation of low (DECT80 kVp) and high energy (DECT140 kVp) series. Surgical extraction and Fourier spectroscopy resulted in 82 calculi. Of these stones 51 showed minor admixtures (uric acid, ammonium urate, struvite, calcium oxalate monohydrate and brushite) and 31 were polycrystalline (mixtures of calcium oxalate monohydrate/dihydrate and calcium phosphate). Analyses identified stone clusters of equal composition and distinct attenuation descriptors on DECT140 kVp, DECT80 kVp and DECTSlope. Iterative cross-validation of the 3 dual energy computerized tomography data sets was used to identify characteristic attenuation limits for each stone type. Attenuatio profiles showed substantial overlap among various stones on DECT140 kVp (uric acid 427.3±168.1 HU, ammonium urate 429.9±99.7 HU, struvite 480.2±123.5 HU, calcium oxalate monohydrate 852.4±301.4 HU, brushite 863.7±180.1 HU and polycrystalline 858.1±210.5 HU) and on DECT80 kVp (uric acid 493.6±182.8 HU, ammonium urate 591.5±157.9 HU, struvite 712.4±173.9 HU, calcium oxalate monohydrate 1,240.5±494.7 HU, brushite 1,532.1±273.1 HU and polycrystalline 1,358.7±316.8 HU). Statistically spectral separation was not sufficient to characterize stones unambiguously based on DECT140 kVp/DECT80 kVp attenuation. Analysis of attenuation showed sufficient spectral separation on DECTSlope (uric acid 14.9±10.9 U, ammonium urate 56.1±1.8 U, struvite 42.7±1.4 U, calcium oxalate monohydrate 62.8±1.8 U and

  13. Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars

    Energy Technology Data Exchange (ETDEWEB)

    Acar, Buket; Kamburoglu, Kivanc [Dept. of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara (Turkmenistan); Tatar, Ilkan [Dept. of Anatomy, Faculty of Medicine, Hacettepe University, Ankara (Turkmenistan); Arikan, Volkan [Dept. of Anatomy, Faculty of Medicine, Hacettepe University, Ankara (Turkmenistan); Celik, Hakan Hamid [Dept. of Pediatric Dentistry, Faculty of Dentistry, Kirikkale Unversity, Ankara (Turkmenistan); Yuksel, Selcen [Dept. of Biostatistics, Faculty of Medicine, Yildirim Beyazit University, Ankara (Turkmenistan); Ozen, Tuncer [Dept. of Dentomaxillofacial Radiology, Gulhane Military Hospital, Dental Clinics, Ankara (Turkmenistan)

    2015-12-15

    This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images.Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.

  14. Resolution, sensitivity, and in vivo application of high-resolution computed tomography for titanium-coated polymethyl methacrylate (PMMA) dental implants

    NARCIS (Netherlands)

    Cuijpers, V.M.J.I.; Jaroszewicz, J.; Anil, S.; Al Farraj Aldosari, A.; Walboomers, X.F.; Jansen, J.A.

    2014-01-01

    OBJECTIVES: The aims of this study were (i) to determine the spatial resolution and sensitivity of micro- versus nano-computed tomography (CT) techniques and (ii) to validate micro- versus nano-CT in a dog dental implant model, comparative to histological analysis. MATERIAL AND METHODS: To determine

  15. Evaluation of novel computerized tomography scoring systems in human traumatic brain injury: An observational, multicenter study.

    Directory of Open Access Journals (Sweden)

    Eric Peter Thelin

    2017-08-01

    Full Text Available Traumatic brain injury (TBI is a major contributor to morbidity and mortality. Computerized tomography (CT scanning of the brain is essential for diagnostic screening of intracranial injuries in need of neurosurgical intervention, but may also provide information concerning patient prognosis and enable baseline risk stratification in clinical trials. Novel CT scoring systems have been developed to improve current prognostic models, including the Stockholm and Helsinki CT scores, but so far have not been extensively validated. The primary aim of this study was to evaluate the Stockholm and Helsinki CT scores for predicting functional outcome, in comparison with the Rotterdam CT score and Marshall CT classification. The secondary aims were to assess which individual components of the CT scores best predict outcome and what additional prognostic value the CT scoring systems contribute to a clinical prognostic model.TBI patients requiring neuro-intensive care and not included in the initial creation of the Stockholm and Helsinki CT scoring systems were retrospectively included from prospectively collected data at the Karolinska University Hospital (n = 720 from 1 January 2005 to 31 December 2014 and Helsinki University Hospital (n = 395 from 1 January 2013 to 31 December 2014, totaling 1,115 patients. The Marshall CT classification and the Rotterdam, Stockholm, and Helsinki CT scores were assessed using the admission CT scans. Known outcome predictors at admission were acquired (age, pupil responsiveness, admission Glasgow Coma Scale, glucose level, and hemoglobin level and used in univariate, and multivariable, regression models to predict long-term functional outcome (dichotomizations of the Glasgow Outcome Scale [GOS]. In total, 478 patients (43% had an unfavorable outcome (GOS 1-3. In the combined cohort, overall prognostic performance was more accurate for the Stockholm CT score (Nagelkerke's pseudo-R2 range 0.24-0.28 and the Helsinki CT score

  16. Accuracy of computerized tomography for the evaluation of mandibular sites prior to implant placement

    DEFF Research Database (Denmark)

    Sforza, Nicola Marco; Franchini, Federico; Lamma, Achille

    2007-01-01

    The objective of the present study was to observe the effect of positioning of the mandible on the accuracy of cross-sectional images obtained by reformatting computerized tomographic (CT) scans. An additional aim was to evaluate the ability of a software program (DentalVox, Era Scientific) to re...

  17. Occupancy of dopamine D{sub 2} receptors in the mouse brain measured using ultra-high-resolution single-photon emission tomography and [{sup 123}I]IBF

    Energy Technology Data Exchange (ETDEWEB)

    Acton, Paul D.; Hou, Catherine; Kung, Mei-Ping; Ploessl, Karl; Keeney, Cindy L. [Department of Radiology, University of Pennsylvania, 3700 Market Street, Room 305, Philadelphia, PA 19104 (United States); Kung, Hank F. [Department of Radiology, University of Pennsylvania, 3700 Market Street, Room 305, Philadelphia, PA 19104 (United States); Department of Pharmacology, University of Pennsylvania, Philadelphia (United States)

    2002-11-01

    Functional imaging of small animals, such as mice and rats, using ultra-high-resolution positron emission tomography (PET) and single-photon emission tomography (SPET) should be a valuable tool in studies of drug occupancy of cerebral binding sites. In this study we aimed to demonstrate the feasibility of using ultra-high-resolution SPET to measure the occupancy of dopamine D{sub 2} receptors by a competing drug, using the dopamine D{sub 2} receptor-specific radioligand iodine-123 5-iodo-7-N-[(1-ethyl-2-pyrrolidinyl) methyl] carboxamido-2,3-dihydrobenzofuran ([{sup 123}I]IBF). Fourteen normal male mice (CD-1) were jugular vein-cannulated and a bolus infusion protocol was used to deliver 360 MBq [{sup 123}I]IBF into the mouse (bolus-to-infusion ratio 1.8:1). The mice were scanned using an ultra-high-resolution triple-headed SPET system equipped with pinhole collimators. After sustained equilibrium had been achieved, varying doses of raclopride, a potent dopamine D{sub 2} receptor antagonist, were injected through the tail vein and the tracer was allowed to regain equilibrium. A simple equilibrium ratio of striatum to cerebellum provided a measure of D{sub 2} receptor binding both before and after injection of raclopride. Following raclopride administration, the system returned to equilibrium with lower specific binding in the striatum, while the counts in the cerebellum were unaffected. Receptor occupancy was 5.2%{+-}2.9% (control), 52.1%{+-}11.1% (0.3 mg/kg), 79.3%{+-}4.8% (1.0 mg/kg), and 94.7%{+-}2.2% (3.0 mg/kg), which gave an ED{sub 50}=0.26{+-}0.03 mg/kg using a single receptor site saturation model. This study has demonstrated clearly that ultra-high-resolution SPET of small animals is capable of measuring displacement and occupancy of dopamine D{sub 2} receptors by competing ligands. (orig.)

  18. Radiation conditions for computerized tomography: determination and comparison; Condicoes de radiacao para tomografia computadorizada: determinacao e comparacoes

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Lucio das Chagas de

    2016-07-01

    Radiology is the practice in which radiation beams, usually radiation X are used to produce an image of the human body in order to obtain a diagnosis, for example, to evaluate a pathological condition by computerized tomography (CT). Although the computerized tomography diagnostic potential is unquestionable, caution must be taken because the doses are almost always higher than the observed in conventional radiology procedures. The ionization chamber used for dosimetry in CT is a unsealed cylindrical chamber with 10 cm and 15 cm of sensitive length. A typical characteristics of this camera is its uniform response to radiation incident at all angles around its axis. The revised edition of IEC 61267 (2005) brought as an innovation the radiation conditions for computed tomography, RQT, that simulate non-attenuated beam and are used in special CT applications. This study aims to establish the necessary conditions to obtain radiation pattern beam computed tomography, RQT, and a calibration laboratory implementation for pencil ionization chambers used in the beam dosimetry produced by these scanners in the Metrology National Laboratory of Ionizing Radiation (LNMRI). In the implementation of RQT conditions we were found that the ratio of kerma rates in the air, with or without additional filtration equivalent to the first HVL (half-value layer), are in accordance with IEC 61267 (2005), which provides a range between 48.5% and 51.5% for each quality. The LNMRI characterized the radiation conditions of RQT series (IEC, 2005), obtaining a percentage of 49.6% for the RQT 8, 50% for the RQT 9 and 50,4% for the RQT 10. With the substitution of the total additional filtration RQT qualities, composed by Al + Cu and by a total filtration composed by copper (Cu) only, it can be seen the emergence of a similar RQT quality named Quality Copper Tomography - QCT. The results of the calibration, the RQT and QCT qualities, had expanded uncertainties with a confidence level 95.45%, less

  19. Cranial anatomy of the spade-headed amphisbaenian Diplometopon zarudnyi (Squamata, Amphisbaenia) based on high-resolution X-ray computed tomography.

    Science.gov (United States)

    Maisano, Jessica Anderson; Kearney, Maureen; Rowe, Timothy

    2006-01-01

    The skull of the trogonophid amphisbaenian Diplometopon zarudnyi is described from high-resolution X-ray computed tomographic (HRXCT) imagery of a whole museum specimen preserved in ETOH. The skull was digitally resliced and disarticulated into individual elements, producing novel visualizations that allow detailed morphological analysis of its three-dimensionally complex structure. The prefrontal and jugal are absent in Diplometopon. The septomaxilla is present but hidden entirely from superficial view. In contrast to previous studies, we recognize a splenial fused to the compound bone of the mandible and a squamosal fused to the otic-occipital complex. Comparison of Diplometopon to the two other amphisbaenians previously described in comparable detail, Rhineura hatcherii and Amphisbaena alba, reveals a mosaic of cranial similarities and differences. Both Diplometopon and Rhineura exhibit a craniofacial angulation and expanded rostral blade related to use of the head as a digging tool, but the detailed architecture of these features is quite different. Additionally, whereas the snout of Rhineura exhibits a high degree of sculpturing and sensory innervation, this is not the case in Diplometopon. Unlike in Rhineura and Amphisbaena, the cranial elements of Diplometopon do not exhibit an extensive degree of overlap or complex interlocking sutures; instead, most of the cranial elements lie in loose apposition to each other. The degree to which this mosaic of features reflects functional demands, shared ancestry, and/or convergence is unclear in the absence of a stable hypothesis of amphisbaenian phylogeny. (c) 2004 Wiley-Liss, Inc.

  20. Using computerized tomography to determine ionospheric structures. Part 1, Notivation and basic approaches

    Energy Technology Data Exchange (ETDEWEB)

    Vittitoe, C.N.

    1993-08-01

    Properties of the ionosphere are reviewed along with its correlations with other geophysical phenomena and with applications of ionospheric studies to communication, navigation, and surveillance systems. Computer tomography is identified as a method to determine the detailed, three-dimensional distribution of electron density within the ionosphere. Several tomography methods are described, with a basic approach illustrated by an example. Limitations are identified.

  1. The Pattern of significant lesions found in computerized tomography scan of recurrent seizure patients at a center in Enugu, Nigeria.

    Science.gov (United States)

    Ezeala-Adikaibe, A B; Ohaegbulam, S C; Ndubuisi, C A

    2017-10-01

    Seizures are common reasons for neurologic consultations and investigations. In the absence of magnetic resonance imaging, computerized tomography scanning of the brain is a reliable and cheaper alternative. Little is known about the pattern of brain lesions in patients with recurrent seizures in Nigeria. To determine the pattern of significant intracerebral lesions in patients presenting with recurrent seizures in a tertiary hospital in Enugu. All the medical and computer tomography records of patients with a clinical diagnosis of recurrent seizures were reviewed. The study duration was 11 years (January 2003 to December 2013). Relevant data were obtained and statistical analysis was done using SPSS version 19 and GraphPad Prism 6. The diagnostic yield of CT was 55.1%. Twenty (9.3%) individuals had two lesions each. The significant findings were tumors (20.4%), encephalomalacia (18.9%) and strokes (7.7% (ischemic stroke, 4.1%, intracerebral hemorrhage, 3.1%, subarachnoid hemorrhage/intraventricular hemorrhage, 0.5%). Hydrocephalus (HCP) was found in 18 (9.2%) cases, and 30% of them occurred together with other lesions. The diagnostic yield increased with age reaching 84.4% from the age of 60 years. Only patients with encephalomalacia were statistically older than those with normal imaging. Computed tomography scan has a high diagnostic yield, especially in elderly patients with recurrent generalized seizures. Brain tumors, encephalomalacia, and HCP are most common causes of recurrent seizures in the adults.

  2. A tomografia computadorizada de alta resolução na avaliação da toxicidade pulmonar por amiodarona High-resolution computed tomography of amiodarone pulmonary toxicity

    Directory of Open Access Journals (Sweden)

    Daniela Peixoto Consídera

    2006-04-01

    Full Text Available OBJETIVO: Avaliar as principais alterações identificadas na tomografia computadorizada de alta resolução do tórax em pacientes com toxicidade pulmonar pela amiodarona. MATERIAIS E MÉTODOS: Foram avaliadas dez tomografias computadorizadas de alta resolução de tórax de pacientes com pneumonite pela amiodarona, seis desses pacientes do sexo masculino e quatro do sexo feminino, com idade média de 73,5 anos. RESULTADOS: Os achados tomográficos mais relevantes foram opacidades lineares ou reticulares em seis casos (60%, pequenos nódulos com densidade elevada em seis casos (60%, consolidações densas em três casos (30% e aumento da densidade do parênquima hepático em cinco de oito casos em que havia estudo tomográfico do abdome superior (62,5%. CONCLUSÃO: A tomografia computadorizada de alta resolução é um exame importante na avaliação de pacientes com toxicidade pulmonar pela amiodarona, devendo ser realizada sempre que houver suspeita deste diagnóstico. O achado de espessamento de septos interlobulares associado a lesões com aumento de densidade é altamente sugestivo deste diagnóstico.OBJECTIVE: To evaluate the main findings of chest high-resolution computed tomography in patients with amiodarone pulmonary toxicity. MATERIALS AND METHODS: Ten patients - six male and four female, average age of 73.5 years - with amiodarone-induced pneumonitis have undergone chest high-resolution computed tomography. RESULTS: The most relevant tomographic findings were linear or reticular opacities in six cases (60%, small high density nodules in six cases (60%, dense consolidations in three cases (30% and increased density in the hepatic parenchyma in five of eight cases in which there was a superior abdomen CT scan (62.5%. CONCLUSION: The high-resolution computed tomography is a valuable non-invasive test for evaluating patients with amiodarone pulmonary toxicity and should always be performed when one suspects of the presence of this

  3. Thirteen-Year Evaluation of Highly Cross-Linked Polyethylene Articulating With Either 28-mm or 36-mm Femoral Heads Using Radiostereometric Analysis and Computerized Tomography

    DEFF Research Database (Denmark)

    Nebergall, Audrey K; Greene, Meridith E; Rubash, Harry E

    2016-01-01

    is a concern with this material through the use of plain radiographs and computerized tomography (CT). METHODS: All patients received a Longevity HXLPE liner with tantalum beads and either a 28-mm or 36-mm femoral head. Twelve patients (6 in each head size group) agreed to return for 13-year RSA, plain...

  4. Dose profile measurement in computerized axial tomography equipment using thermoluminescent dosemeters; Medicion del perfil de dosis en equipos de tomografia axial computarizada usando dosimetros termoluminiscentes

    Energy Technology Data Exchange (ETDEWEB)

    Azorin V, J.C.; Falcony, C.; Azorin N, J. [Centro de Investigacion en Ciencia y Tecnologia Avanzada, IPN, 07000 Mexico D.F. (Mexico)

    2000-07-01

    In this work are presented the results about measuring the radiation dose profile in two equipment of computerized axial tomography (Tac). Thermoluminescent dosemeters (Dtl) of LiF, Mg, Cu, P + Ptfe in form of disks were used which were developed and made in Mexico. The results showed that Dtl are appropriated for these type of studies. (Author)

  5. High-resolution infrared imaging

    Science.gov (United States)

    Falco, Charles M.

    2010-08-01

    The hands and mind of an artist are intimately involved in the creative process of image formation, intrinsically making paintings significantly more complex than photographs to analyze. In spite of this difficulty, several years ago the artist David Hockney and I identified optical evidence within a number of paintings that demonstrated artists began using optical projections as early as c1425 - nearly 175 years before Galileo - as aids for producing portions of their images. In the course of our work, Hockney and I developed insights that I have been applying to a new approach to computerized image analysis. Recently I developed and characterized a portable high resolution infrared for capturing additional information from paintings. Because many pigments are semi-transparent in the IR, in a number of cases IR photographs ("reflectograms") have revealed marks made by the artists that had been hidden under paint ever since they were made. I have used this IR camera to capture photographs ("reflectograms") of hundreds of paintings in over a dozen museums on three continents and, in some cases, these reflectograms have provided new insights into decisions the artists made in creating the final images that we see in the visible.

  6. A new high resolution computed tomography scoring system for pulmonary fibrosis, pleural disease, and emphysema in patients with asbestos related disease.

    Science.gov (United States)

    Jarad, N A; Wilkinson, P; Pearson, M C; Rudd, R M

    1992-02-01

    The aim of this study was to describe a scoring system for high resolution computed tomographic (HRCT) scans analogous to the International Labour Office (ILO) scoring system for plain chest radiographs in patients with asbestos related disease. Interstitial fibrosis, pleural disease, and emphysema were scored, the reproducibility and the interobserver agreement using this scoring system were examined, and the extent of the various types of disease was correlated with measurements of lung function. Sixty asbestos workers (five women and 55 men) mean age 59 (range 34-78) were studied. The lungs were divided into upper, middle, and lower thirds. An HRCT score for the extent of pleural disease and pulmonary disease in each third was recorded in a way analogous to the International Labour Office (ILO) method of scoring pleural and parenchymal disease on chest radiographs. A CT score for the extent of emphysema was also recorded. Pleural disease and interstitial fibrosis on the plain chest radiographs were assessed according to the ILO scoring system. A chest radiographic score for emphysema analogous to that used for HRCT was also recorded. Two independent readers assigned HRCT scores that differed by two categories or less in 96%, 92%, and 85% compared with 90%, 78%, and 79% of cases for chest radiographs for fibrosis, emphysema, and pleural disease respectively. There was better intraobserver repeatability for the HRCT scores than for the chest radiograph scores for all disorders. Multiple regression analysis showed that scores for interstitial fibrosis, emphysema, and pleural disease on chest radiographs and HRCT correlated to a similar degree with impairment of lung function.

  7. Rare bilateral C6 spondylolysis and spondylolisthesis in an adolescent athlete: evaluation with magnetic resonance imaging and multidetector computerized tomography.

    Science.gov (United States)

    Amin, Mohammed F; Mollano, Anthony V; Weinstein, Stuart L; El-Khoury, George Y

    2006-10-01

    Case report. To show a rare case of cervical spondylolysis and spondylolisthesis secondary to bilateral stress fractures at the pedicle laminar junction of C6 in a 16-year-old athlete playing high school baseball. The patient presented with 3 months of neck pain and intermittent right arm radicular symptoms. Plain radiographs and multidetector computerized tomography (CT) of the cervical spines. Plain radiographs revealed loss of lower cervical lordosis. Multidetector CT indicated bilateral C6 spondylolysis. Magnetic resonance imaging showed bilateral marrow edema at the pedicle laminar junction of C6. Treatment included placing his neck in a Philadelphia collar for 6 weeks. Follow-up CT revealed progression of healing. Early diagnosis and appropriate management of these cases are important to promote healing.

  8. [Role of computeric tomography and magnetic resonance imaging in diagnosis of inflammatory diseases of sacro-ileal joint].

    Science.gov (United States)

    Baĭramov, R B

    2012-05-01

    Sensitivity of computeric tomography (CT) and magnetic resonance imaging (MRI) for sacroileitis diagnosis was studied, optimal for MRI investigation was established. In 31 patients, owing obvious clinical signs of inflammatory sacroileitis (at average more than 5 mo duration of a low back pain) MRI of sacroiliac joint was conducted in a T1, T2 FS, 2D T2 FLASH regimes and after intravenous infusion of a contrast substance (gadolinium) - in a T1 FS regime, using system, owing a 1,5 T magnetic field intensity. The data obtained were compared with results of CT. Sacroileitis signs were revealed in 27 patients - according to CT data, and in 22 - MRI. CT have demonstrated as a more sensitive method of the bone erosion and sclerosis diagnosis, than MRI. MRI is more sensitive while revealing an active inflammatory process in the bone and joint space. While T1 FS application no additional information for sacroileitis diagnosis was obtained.

  9. High-speed, high-resolution Fourier-domain optical coherence tomography system for retinal imaging in the 1060 nm wavelength region.

    Science.gov (United States)

    Puvanathasan, Prabakar; Forbes, Peter; Ren, Zhao; Malchow, Doug; Boyd, Shelley; Bizheva, Kostadinka

    2008-11-01

    A high-speed (47,000 A-scans/s), ultrahigh axial resolution Fourier domain optical coherence tomography (OCT) system for retinal imaging at approximately 1060 nm, based on a 1024 pixel linear array, 47 kHz readout rate InGaAs camera is presented. When interfaced with a custom superluminescent diode (lambda(c) = 1020 nm, Deltalambda = 108 nm, Pout = 9 mW), the system provides 3.3 microm axial OCT resolution at the surface of biological tissue, approximately 4.5 microm in vivo in rat retina, approximately 5.7 microm in vivo in human retina, and 110 dB sensitivity for 870 microW incident power and 21 mus integration time. Retinal tomograms acquired in vivo from a human volunteer and a rat animal model show clear visualization of all intraretinal layer and increased penetration into the choroid.

  10. High-resolution computed tomography findings in pulmonary complications after bone marrow transplantation: iconographic essay; Tomografia computadorizada de alta resolucao nas complicacoes pulmonares pos-transplante de medula ossea: ensaio iconografico

    Energy Technology Data Exchange (ETDEWEB)

    Gasparetto, Emerson L.; Ono, Sergio E.; Souza, Carolina A. [Parana Univ., Curitiba, PR (Brazil). Hospital de Clinicas. Servico de Radiologia Medica e Diagnostico por Imagem]. E-mail: gasparetto@hotmail.com; Escuissato, Dante L. [Parana Univ., Curitiba, PR (Brazil). Faculdade de Medicina. Disciplina de Radiologia Medica; Rocha, Gabriela de Melo; Inoue, Cezar; Falavigna, Joao M. [Parana Univ., Curitiba, PR (Brazil). Faculdade de Medicina; Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Faculdade de Medicina. Dept. de Radiologia; Universidade Federal, Rio de Janeiro (UFRJ), RJ (Brazil). Curso de Pos-graduacao em Radiologia

    2005-12-01

    Bone marrow transplantation has been the treatment of choice for many hematologic diseases. However, pulmonary complications, which may occur in up to 60% of the patients, are the main cause of treatment failure and may be divided in three phases according to the patient's immunity. In the first phase, up to 30 days after the procedure, there is a predominance of non-infectious complications and fungal pneumonia. Viral infections, mainly by cytomegalovirus, are common in the second phase (up to 100 days after bone marrow transplantation). Finally, in the late phase after bone marrow transplantation, non-infectious complications as bronchiolitis obliterans organizing pneumonia and graft-versus-host disease are most commonly seen. The authors present a pictorial essay of the high-resolution computed tomography findings in patients with pulmonary complications after bone marrow transplantation. (author)

  11. Can faults become barriers for deep fluid circulation? Insights from high-resolution seismic VSP tomography at the Soultz-sous-Forêts geothermal site

    Science.gov (United States)

    Calò, Marco; Dorbath, Catherine; Lubrano Lavadera, Paul

    2016-09-01

    Vertical Seismic Profile (VSP) surveys are generally used for modelling converted phases of the seismic body waves propagating in the medium allowing the detection of waves interpreted as reflections on steeply dipping reflecting structures such as faults, abrupt lateral changes of lithology, and fractures. At the Enhanced Geothermal System geothermal field of Soultz-sous-Forêts the analysis of data recorded during a VSP experiment allowed describing the presence of at least two structures near the wells. Here we show how seismic tomography method can be applied to the VSP data to reconstruct the 3-D shape of structures in the volume surrounding the geothermal wells. The three-dimensional P wave velocity model obtained shows positive velocity anomalies associated with the main faults observed by the VSP analysis and negative anomalies in the regions affected by massive hydraulic stimulations performed in the past. This pattern can be explained as a different response of the rock volume to the fluid injections where regions marked by relative pre-existing high permeability were less affected by the hydraulic stimulations. This difference in permeability produced regions that could work as barriers for fluid diffusion through the reservoir. Comparisons of our high resolved model with the location of the induced seismicity and with another model obtained using seismic noise correlation give evidence of the presence of these structures and may explain the poor connection between the wells GPK4 and GPK2-GPK3 system.

  12. Dispersion-flattened supercontinuum light source design at 1.0 μm center wavelength for high resolution optical coherence tomography in ophthalmology

    Science.gov (United States)

    Hossain, M. A.; Namihira, Y.

    2013-06-01

    Optimal wavelength light sources are designed for medical imaging to overcome the effects of the dispersion of the sampling medium of biological tissues which contain about 60% water in normal tissues and 90% water in anatomic structures such as in the eye. Based on highly nonlinear photonic crystal fiber (HNL-PCF), two light sources are designed at 1.0 μm center wavelength as the influences of the dispersion of the main component of biological tissues on the resolution of optical coherence tomography (OCT) can be eliminated. Using finite element method with a circular perfectly matched boundary layer, it is shown through simulations that the proposed HNL-PCFs offer efficient SC generation for such applications at 1.0 μm. By propagating sech2 picoseconds optical pulses having 1.0 ps pulse width at a full width at half maximum through the proposed HNL-PCFs, output optical pulses are analyzed by the split-step Fourier method to obtain the spectral properties. Simulation results show that 270 m of the proposed HNL-PCF can produce highest 95 nm spectrum (10 dB bandwidth) or 62 nm spectrum (3 dB bandwidth). Therefore, the highest longitudinal resolutions in the depth direction for medical OCT imaging is found about 3.3 μm (using 10 dB bandwidth) or 5.1 μm (using 3 dB bandwidth), respectively, for biological tissues.

  13. Magnetoacoustic tomography with magnetic induction for high-resolution bioimepedance imaging through vector source reconstruction under the static field of MRI magnet.

    Science.gov (United States)

    Mariappan, Leo; Hu, Gang; He, Bin

    2014-02-01

    Magnetoacoustic tomography with magnetic induction (MAT-MI) is an imaging modality to reconstruct the electrical conductivity of biological tissue based on the acoustic measurements of Lorentz force induced tissue vibration. This study presents the feasibility of the authors' new MAT-MI system and vector source imaging algorithm to perform a complete reconstruction of the conductivity distribution of real biological tissues with ultrasound spatial resolution. In the present study, using ultrasound beamformation, imaging point spread functions are designed to reconstruct the induced vector source in the object which is used to estimate the object conductivity distribution. Both numerical studies and phantom experiments are performed to demonstrate the merits of the proposed method. Also, through the numerical simulations, the full width half maximum of the imaging point spread function is calculated to estimate of the spatial resolution. The tissue phantom experiments are performed with a MAT-MI imaging system in the static field of a 9.4 T magnetic resonance imaging magnet. The image reconstruction through vector beamformation in the numerical and experimental studies gives a reliable estimate of the conductivity distribution in the object with a ∼ 1.5 mm spatial resolution corresponding to the imaging system frequency of 500 kHz ultrasound. In addition, the experiment results suggest that MAT-MI under high static magnetic field environment is able to reconstruct images of tissue-mimicking gel phantoms and real tissue samples with reliable conductivity contrast. The results demonstrate that MAT-MI is able to image the electrical conductivity properties of biological tissues with better than 2 mm spatial resolution at 500 kHz, and the imaging with MAT-MI under a high static magnetic field environment is able to provide improved imaging contrast for biological tissue conductivity reconstruction.

  14. Assessment of interstitial lung disease in Sjögren's syndrome by lung ultrasound: a pilot study of correlation with high-resolution chest tomography.

    Science.gov (United States)

    Vasco, Pablo Guisado; de Luna Cardenal, Gonzalo; Garrido, Isabel Martín; Pinilla, José Manuel Luque; Rodríguez, Guadalupe Fraile; Mateo, Juan José Nava; Ruiz, Daniel Carnevalli

    2017-04-01

    The background of this study is to assess the accuracy of lung ultrasound (LUS) to diagnose interstitial lung disease (ILD) in Sjögren's syndrome (Sjs), in patients who have any alterations in pulmonary function tests (PFT) or respiratory symptoms. LUS was correlated with chest tomography (hrCT), considering it as the imaging gold standard technique to diagnose ILD. This is a pilot, multicenter, cross-sectional, and consecutive-case study. The inclusion criteria are ≥18 years old, Signs and symptoms: according to ACEG 2002 criteria, respiratory symptoms (dyspnea, cough), or any alterations in PFR. LUS was done following the International Consensus Conference on Lung Ultrasound protocol for interstitial syndrome (B pattern). Of the 50 patients in follow-up, 13 (26%) met the inclusion criteria. All were women with age 63.62 years (range 39-88). 78.6% of the cases had primary Sjs (SLE, RA, n = 2). The intra-rater reliability k is 1, according to Gwet's Ac1 and GI index (probability to concordance-e(K)-, by Cohen, of 0.52). LUS has a sensitivity of 1 (95% CI 0.398-1.0), specificity of 0.89 (95% CI 0.518-0.997), and a positive probability reason of 9.00 (95% CI 7.1-11.3) to detect ILD. The correlation of Pearson is r = 0.84 (p < 0.001). To check the accuracy of LUS to diagnose ILD, a completely bilateral criterion of yes/no for interstitial pattern was chosen, AUC reaches significance, 0.94 (0.07) (95% CI 0.81-1.0, p = 0.014). LUS reaches an excellent correlation to hrCT in Sjs affected with ILD, and might be a useful technique in daily clinical practice for the assessment of pulmonary disease in the sicca syndrome.

  15. The potential of positron emission tomography/computerized tomography (PET/CT) scanning as a detector of high-risk patients with oral infection during preoperative staging.

    Science.gov (United States)

    Yamashiro, Keisuke; Nakano, Makoto; Sawaki, Koichi; Okazaki, Fumihiko; Hirata, Yasuhisa; Takashiba, Shogo

    2016-08-01

    It is sometimes difficult to determine during the preoperative period whether patients have oral infections; these patients need treatment to prevent oral infection-related complications from arising during medical therapies, such as cancer therapy and surgery. One of the reasons for this difficulty is that basic medical tests do not identify oral infections, including periodontitis and periapical periodontitis. In this report, we investigated the potential of positron emission tomography/computerized tomography (PET/CT) as a diagnostic tool in these patients. We evaluated eight patients during the preoperative period. All patients underwent PET/CT scanning and were identified as having the signs of oral infection, as evidenced by (18)F-fludeoxyglucose (FDG) localization in the oral regions. Periodontal examination and orthopantomogram evaluation showed severe infection or bone resorption in the oral regions. (18)F-FDG was localized in oral lesions, such as severe periodontitis, apical periodontitis, and pericoronitis of the third molar. The densities of (18)F-FDG were proportional to the degree of inflammation. PET/CT is a potential diagnostic tool for oral infections. It may be particularly useful in patients during preoperative staging, as they frequently undergo scanning at this time, and those identified as having oral infections at this time require treatment before cancer therapy or surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Ground-glass opacity in diffuse lung diseases: high-resolution computed tomography-pathology correlation; Opacidades em vidro fosco nas doencas pulmonares difusas: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Maria Lucia de Oliveira; Vianna, Alberto Domingues; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Disciplina de Radiologia; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Patologia]. E-mail: edmarchiori@zipmail.com.br

    2003-12-01

    Ground-glass opacity is a finding frequently seen in high-resolution computed tomography examinations of the chest and is characterized by hazy increased attenuation of lung, however without blurring of bronchial and vascular margins. Due to its un specificity, association with other radiological, clinical and pathological findings must be considered for an accurate diagnostic interpretation. In this paper were reviewed 62 computed tomography examinations of patients with diffuse pulmonary diseases of 14 different etiologies in which ground-glass opacity was the only or the most remarkable finding, and correlated this findings with pathology abnormalities seen on specimens obtained from biopsies or necropsies. In pneumocystosis, ground-glass opacities correlated histologically with alveolar occupation by a foaming material containing parasites, in bronchiole alveolar cell carcinoma with thickening of the alveolar septa and occupation of the lumen by mucus and tumoral cells, in paracoccidioidomycosis with thickening of the alveolar septa, areas of fibrosis and alveolar bronchopneumonia exudate, in sarcoidosis with fibrosis or clustering of granulomas and in idiopathic pulmonary fibrosis with alveolar septa thickening due to fibrosis. Alveolar occupation by blood was found in cases of leptospirosis, idiopathic hemo siderosis, metastatic kidney tumor and invasive aspergillosis whereas oily vacuole were seen in lipoid pneumonia, proteinaceous and lipo proteinaceous material in silico proteinosis and pulmonary alveolar proteinosis, and edematous fluid in cardiac failure. (author)

  17. Computerized tomography using monoenergetic X-ray; Tomografia computadorizada com raios-X monoenergetico

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Ernande B. da [Universidade Federal Rural de Pernambuco, Recife, PE (Brazil). Dept. de Fisica; Lopes, Ricardo T.; Ladeira, Carlos L. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Lab. de Instrumentacao Nuclear

    1996-12-31

    The use of filters place in X-ray beam to produce quasi-monoenergetic radiation and its utilization in tomography are described. The filters are 100{mu}m of Cu, 25 and 50{mu}m of Rh and filters prepared with resins, 40 mg/cm{sup 2}-Cd. A comparison of the acquired images is presented 3 refs., 5 figs.

  18. The role of facial canal diameter in the pathogenesis and grade of Bell's palsy: a study by high resolution computed tomography

    Directory of Open Access Journals (Sweden)

    Onur Celik

    Full Text Available Abstract Introduction: The exact etiology of Bell's palsy still remains obscure. The only authenticated finding is inflammation and edema of the facial nerve leading to entrapment inside the facial canal. Objective: To identify if there is any relationship between the grade of Bell's palsy and diameter of the facial canal, and also to study any possible anatomic predisposition of facial canal for Bell's palsy including parts which have not been studied before. Methods: Medical records and temporal computed tomography scans of 34 patients with Bell's palsy were utilized in this retrospective clinical study. Diameters of both facial canals (affected and unaffected of each patient were measured at labyrinthine segment, geniculate ganglion, tympanic segment, second genu, mastoid segment and stylomastoid foramen. The House-Brackmann (HB scale of each patient at presentation and 3 months after the treatment was evaluated from their medical records. The paired samples t-test and Wilcoxon signed-rank test were used for comparison of width between the affected side and unaffected side. The Wilcoxon signed-rank test was also used for evaluation of relationship between the diameter of facial canal and the grade of the Bell's palsy. Significant differences were established at a level of p = 0.05 (IBM SPSS Statistics for Windows, Version 21.0.; Armonk, NY, IBM Corp. Results: Thirty-four patients - 16 females, 18 males; mean age ± Standard Deviation, 40.3 ± 21.3 - with Bell's palsy were included in the study. According to the HB facial nerve grading system; 8 patients were grade V, 6 were grade IV, 11 were grade III, 8 were grade II and 1 patient was grade I. The mean width at the labyrinthine segment of the facial canal in the affected temporal bone was significantly smaller than the equivalent in the unaffected temporal bone (p = 0.00. There was no significant difference between the affected and unaffected temporal bones at the geniculate ganglion (p = 0

  19. Computerized tomography magnified bone windows are superior to standard soft tissue windows for accurate measurement of stone size: an in vitro and clinical study.

    Science.gov (United States)

    Eisner, Brian H; Kambadakone, Avinash; Monga, Manoj; Anderson, James K; Thoreson, Andrew A; Lee, Hang; Dretler, Stephen P; Sahani, Dushyant V

    2009-04-01

    We determined the most accurate method of measuring urinary stones on computerized tomography. For the in vitro portion of the study 24 calculi, including 12 calcium oxalate monohydrate and 12 uric acid stones, that had been previously collected at our clinic were measured manually with hand calipers as the gold standard measurement. The calculi were then embedded into human kidney-sized potatoes and scanned using 64-slice multidetector computerized tomography. Computerized tomography measurements were performed at 4 window settings, including standard soft tissue windows (window width-320 and window length-50), standard bone windows (window width-1120 and window length-300), 5.13x magnified soft tissue windows and 5.13x magnified bone windows. Maximum stone dimensions were recorded. For the in vivo portion of the study 41 patients with distal ureteral stones who underwent noncontrast computerized tomography and subsequently spontaneously passed the stones were analyzed. All analyzed stones were 100% calcium oxalate monohydrate or mixed, calcium based stones. Stones were prospectively collected at the clinic and the largest diameter was measured with digital calipers as the gold standard. This was compared to computerized tomography measurements using 4.0x magnified soft tissue windows and 4.0x magnified bone windows. Statistical comparisons were performed using Pearson's correlation and paired t test. In the in vitro portion of the study the most accurate measurements were obtained using 5.13x magnified bone windows with a mean 0.13 mm difference from caliper measurement (p = 0.6). Measurements performed in the soft tissue window with and without magnification, and in the bone window without magnification were significantly different from hand caliper measurements (mean difference 1.2, 1.9 and 1.4 mm, p = 0.003, window settings with magnification. For uric acid calculi the measurement error was observed only in standard soft tissue window settings. In vivo 4.0x

  20. Fibrose maciça progressiva em trabalhadores expostos à sílica: achados na tomografia computadorizada de alta resolução Progressive massive fibrosis in silica-exposed workers: high-resolution computed tomography findings

    Directory of Open Access Journals (Sweden)

    Ângela Santos Ferreira

    2006-12-01

    Full Text Available OBJETIVO: Avaliar as características radiológicas das massas conglomeradas pela tomografia computadorizada de alta resolução de tórax. MÉTODOS: Foram selecionados 75 pacientes silicóticos, a maioria jateadores de areia, portadores de fibrose maciça progressiva, atendidos no Hospital Universitário Antônio Pedro entre 1986 e 2004. Os pacientes foram submetidos a avaliação clínica, radiografia simples de tórax e tomografia computadorizada de alta resolução. RESULTADOS: Mais da metade dos pacientes com silicose complicada mostrou na radiografia de tórax grandes opacidades dos tipos B e C, denotando a gravidade da doença nesses pacientes. Dos 75 casos, apenas um apresentou massa unilateral simulando câncer de pulmão. Quarenta e quatro pacientes realizaram tomografia computadorizada de alta resolução do tórax. As massas predominaram nos terços superiores e posteriores (88,6%. Broncograma aéreo e calcificações no interior das massas foram observados em 70,4% e 63,8% dos casos, respectivamente. História de tuberculose foi relatada em 52% dos pacientes estudados. CONCLUSÃO: Na grande maioria dos casos as massas eram bilaterais, predominando nas regiões póstero-superiores dos pulmões, com broncogramas aéreos e calcificações de permeio. Associação com calcificações linfonodais foi um achado freqüente. A exposição a elevadas concentrações de poeira e a tuberculose foram consideradas fatores de risco para o desenvolvimento da fibrose maciça progressiva.OBJECTIVE: To evaluate the radiological characteristics of conglomerate masses using high-resolution computed tomography of the chest. METHODS: From among the patients treated between 1986 and 2004 at the Antonio Pedro University Hospital, 75 patients with silicosis and massive fibrosis, most working in the field of sandblasting, were selected for study. These patients were submitted to a clinical evaluation, chest X-ray and high-resolution computed tomography of

  1. [Contribution of computerized tomography in the diagnosis of cerebrovascular accidents in Nouakchott, Mauritania].

    Science.gov (United States)

    Diagana, M; Traore, H; Bassima, A; Druet-Cabanac, M; Preux, P M; Dumas, M

    2002-01-01

    This prospective study was focused on the radiological features of stroke and the recent contribution of computerized tomographic scan (CT scan) to diagnosis of hospitalized stroke patients. All patients admitted for stroke to the Neurology Department of the Nouakchott Hospital between January 1, 1996 and June 30, 1997 were enrolled in this study. Patients were divided into two groups, i.e. CT group including patients that underwent CT scan during hospitalization and control group including patients that did not undergo CT scan for financial reasons. The etiology of stroke (35.1% of hospitalizations) was ischemic in 52% of cases and hemorrhagic in 48%. There were more men than women and mean age was 60 years for ischemic stroke versus 56 years for hemorrhagic stroke. Only 8% of patients presented documented diabetes. Deep infarction accounted for 52% of ischemic stroke including large-artery infarction in 61.2% and lacunar infarction in 38.8%. Superficial infarction usually involved the territory supplied by the superficial sylvian artery. Intraparenchymal hematomas accounted for 78% of hemorrhagic strokes in relation with the high incidence of arterial hypertension (65.2%). The most common locations were capsulo-lenticular (55%) and capsulo-thalamic (39%). Stroke-related mortality was high (20.3%) especially in patients presenting prolonged disturbances of consciousness and renal insufficiency. By allowing more accurate assessment of lesions, CT-scan improved patient management and therapeutic outcome.

  2. Method of evaluation of diagnostics reference levels in computerized tomography; Metodo de avaliacao de niveis de referencia de radiodiagnostico em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  3. Relative Hypodense Vertebral Artery Sign on Computerized Tomography in Atherosclerotic Near Occlusion

    Directory of Open Access Journals (Sweden)

    Muhammad Faraz Raghib

    2016-01-01

    Full Text Available A 52-year-old white male presented with an acute onset of slurred speech along with hypoesthesia in the entire left arm. The acute computed tomography (CT showed relative hypodensity in the intracranial segment of left vertebral artery (VA that was not present in historical images, pointing to the possible lack of flow. The site of occlusion was confirmed by magnetic resonance imaging (MRI that showed susceptibility effect in the affected artery. By means of historical native CT comparison the site of VA thrombosis was correctly predicted. Local atherosclerotic thrombosis of the VA could be relatively hypodense on native CT and still have positive susceptibility weighted imaging (SWI sign.

  4. Pneumonia lipoídica em adultos: aspectos na tomografia computadorizada de alta resolução Lipoid pneumonia in adults: findings on high-resolution computed tomography

    Directory of Open Access Journals (Sweden)

    Edson Marchiori

    2007-10-01

    Full Text Available OBJETIVO: Apresentar os aspectos na tomografia computadorizada de alta resolução do tórax da pneumonia lipoídica exógena por aspiração de óleo mineral, em pacientes adultos MATERIAIS E MÉTODOS: Foram estudados oito pacientes adultos - quatro mulheres e quatro homens - com média de idade de 69,4 anos, todos usuários de óleo mineral para tratamento de constipação intestinal. Os exames foram avaliados por dois radiologistas, de forma independente RESULTADOS: Os achados tomográficos mais comuns foram as consolidações com áreas de densidade de gordura de permeio, e o padrão de pavimentação em mosaico. As lesões foram bilaterais em seis pacientes, e unilaterais em dois CONCLUSÃO: O encontro de consolidações pulmonares com áreas de densidade de gordura de permeio, associado à história clínica do uso de óleo mineral, é diagnóstico de pneumonia lipoídica exógena.OBJECTIVE: The present study was aimed at describing the findings on high-resolution computed tomography in patients with exogenous lipoid pneumonia secondary to mineral oil aspiration MATERIALS AND METHODS: Eight adult patients - four men and four women - with mean age of 69.4 years were studied. All of the patients were users of mineral oil for treating intestinal constipation. High-resolution computed tomography studies of these patients were blindly evaluated by two radiologists. RESULTS: Air-space consolidation with areas of fat density and crazy paving pattern were the most frequent findings. The lesions were bilateral in six cases and unilateral in two CONCLUSION: Air-space consolidation with areas of fat density, associated with a clinical history of mineral oil ingestion virtually indicates a diagnosis of exogenous lipoid pneumonia.

  5. Is the systematic use of automatic exposure monitoring justified in pediatrics abdomen computerized tomography?; L'utilisation systematique du controle automatique d'exposition est-elle justifiee en TDM abdominale pediatique?

    Energy Technology Data Exchange (ETDEWEB)

    Brisse, H.; Robilliard, M.; Pierrat, N.; Gaboriaud, G.; Neuenschwander, S.; Rosenwald, J.C.; Aubert, B

    2007-10-15

    The use of automatic exposure in pediatrics abdomen computerized tomography induces an increase and possibly useless of the dose to pelvic organs, and then must be justified for what diagnosis is expected from this medical examination. (N.C.)

  6. Virtual Reality Therapy for the Treatment of Alcohol Dependence: A Preliminary Investigation With Positron Emission Tomography/Computerized Tomography.

    Science.gov (United States)

    Son, Ji Hyun; Lee, Sang Hoon; Seok, Ju Won; Kee, Baik Seok; Lee, Hyun Woong; Kim, Hyung Joon; Lee, Tae Kyung; Han, Doug Hyun

    2015-07-01

    Virtual reality therapy (VRT) uses multimodal stimulation that includes visual, auditory, olfactory, and gustatory stimuli. The aim of this study was to assess the effectiveness of VRT in treating subjects with alcohol dependence (AD) by evaluating changes in brain metabolism. The VRT protocol consisted of three steps: relaxation, presentation of a high-risk situation, and presentation of an aversive situation. Twelve alcohol-dependent subjects underwent 10 sessions of VRT. The alcohol-dependent subjects were assessed with 18F-fluorodeoxyglucose positron emission tomography images before and after VRT, whereas the control group underwent imaging according to the same protocol only at baseline. Compared with the healthy control group, AD subjects showed higher metabolism in the right lentiform nucleus and right temporal lobe (BA20) at baseline (P(FDR brain metabolism in the right lentiform nucleus (P(FDR < .05) = .026) and right temporal lobe (BA38, P(FDR < .05) = .032) relative to that at baseline. Our results suggest a neurobiological imbalance, notably, a high sensitivity to stimuli, in the limbic system in subjects with AD. Furthermore, we determined that metabolism decreased in the basal ganglia after VRT, which may explain the limbic-regulated responses of reward and regulation. Therefore, we tentatively recommend VRT to treat AD through its regulating effect on limbic circuits.

  7. Dose profile study on computerized tomography scanning of skull with simulator object; Estudo do perfil de dose em varreduras de TC de cranio com objeto simulador

    Energy Technology Data Exchange (ETDEWEB)

    Mourao, A.P., E-mail: aprata@des.cefetmg.b [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET/MG), Belo Horizonte, MG (Brazil). Nucleo de Engenharia Hospitalar; Alonso, Thessa C.; Silva, Teogenes A. da, E-mail: alonso@cdtn.b, E-mail: silvata@@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-10-26

    This work presents a comparison among the dose profiles in scanning of computerized tomography of a simulator object of PMMA in its periphery region. To obtain the deposited dose at the PMMA thermoluminescent dosemeters were used positioned at the interior of PMMA simulated object longitudinal to periphery and at the center of cylinder (positions denominated North, South, East, West and Center). Eight scanning were performed of simulator object using the routine protocol for skull in eight different services of radiodiagnostic by TC

  8. An Anatomical Study of Maxillary-Zygomatic Complex Using Three-Dimensional Computerized Tomography-Based Zygomatic Implantation

    Directory of Open Access Journals (Sweden)

    Xiangliang Xu

    2017-01-01

    Full Text Available Objective. To obtain anatomical data of maxillary-zygomatic complex based on simulating the zygomatic implantation using cadaver heads and three-dimensional computerized tomography (3D-CT. Methods. Simulating zygomatic implantation was performed using seven cadaver heads and 3D-CT images from forty-eight adults. After measuring the maxillary-zygomatic complex, we analyzed the position between the implantation path and the maxillary sinus cavity as well as the distance between the implantation path and the zygomatic nerve. Results. The distance from the starting point to the endpoint of the implant was 56.85 ± 5.35 mm in cadaver heads and 58.15 ± 7.37 mm in 3D-CT images. For the most common implantation path (80.20%, the implant went through the maxillary sinus cavity completely. The projecting points of the implant axis (IA on the surface of zygoma were mainly located in the region of frontal process of zygomatic bone close to the lateral orbital wall. The distances between IA and zygomatic nerve in 53 sides were shorter than 2 mm. Conclusion. The simulating zygomatic implantation on cadaver skulls and 3D-CT imaging provided useful anatomical data of the maxillary-zygomatic complex. It is necessary to take care to avoid the zygomatic nerve injury during implantation, because it frequently appears on the route of implantation.

  9. Computerized tomography with 3-dimensional reconstruction for the evaluation of renal size and arterial anatomy in the living kidney donor.

    Science.gov (United States)

    Janoff, Daniel M; Davol, Patrick; Hazzard, James; Lemmers, Michael J; Paduch, Darius A; Barry, John M

    2004-01-01

    Computerized tomography (CT) with 3-dimensional (3-D) reconstruction has gained acceptance as an imaging study to evaluate living renal donors. We report our experience with this technique in 199 consecutive patients to validate its predictions of arterial anatomy and kidney volumes. Between January 1997 and March 2002, 199 living donor nephrectomies were performed at our institution using an open technique. During the operation arterial anatomy was recorded as well as kidney weight in 98 patients and displacement volume in 27. Each donor had been evaluated preoperatively by CT angiography with 3-D reconstruction. Arterial anatomy described by a staff radiologist was compared with intraoperative findings. CT estimated volumes were reported. Linear correlation graphs were generated to assess the reliability of CT volume predictions. The accuracy of CT angiography for predicting arterial anatomy was 90.5%. However, as the number of renal arteries increased, predictive accuracy decreased. The ability of CT to predict multiple arteries remained high with a positive predictive value of 95.2%. Calculated CT volume and kidney weight significantly correlated (0.654). However, the coefficient of variation index (how much average CT volume differed from measured intraoperative volume) was 17.8%. CT angiography with 3-D reconstruction accurately predicts arterial vasculature in more than 90% of patients and it can be used to compare renal volumes. However, accuracy decreases with multiple renal arteries and volume comparisons may be inaccurate when the difference in kidney volumes is within 17.8%.

  10. Multislice computerized tomography of the heart and coronary arteries; Exploration par tomodensitometrie multidetecteur du coeur et des arteres coronaires

    Energy Technology Data Exchange (ETDEWEB)

    Dacher, J.N.; Bertrand, D.; Belhiba, H. [Centre Hospitalier Universitaire, Service de Radiologie, Dept. d' Imagerie Medicale, LITIS EA 4108, Hopital Charles-Nicolle, 76 - Rouen (France); Tron, Ch. [Centre Hospitalier Universitaire, Service de Cardiologie, Hopital Charles-Nicolle, 76 - Rouen (France)

    2007-12-15

    Due to its excellent spatial and temporal resolution, multislice computerized tomography (M.S.C.T.) allows visualizing the heart and coronary arteries. Although the indications of M.S.C.T. did not reach a consensus level yet, some trends can be stated. The advantages and limitations of M.S.C.T. in cardiac exploration are summarized in this article. The indications are mainly based on the excellent negative predictive value of M.S.C.T. regarding coronary artery disease. Hence, patients at low to moderate risk of coronary artery disease (CAD) mostly benefit of the technique. M.S.C.T. can be an alternate examination in case of non feasible or non contributive stress test. M.S.C.T. is highly contributive in the ostial analysis, in detecting abnormal coronary implantation or course, in assessing a reimplanted artery or in analysing bypass grafts. M.S.C.T. remains limited in patients with heavily calcified coronary arteries, and in patients with stented distal arteries. (authors)

  11. Differentiation of oncocytoma and renal cell carcinoma in small renal masses (<4 cm): the role of 4-phase computerized tomography.

    Science.gov (United States)

    Bird, Vincent G; Kanagarajah, Prashanth; Morillo, Gaston; Caruso, Daniel J; Ayyathurai, Rajinikanth; Leveillee, Raymond; Jorda, Merce

    2011-12-01

    We investigate the use of 4-phase computerized tomography with intravenous contrast to help distinguish oncocytoma from renal cell carcinoma (RCC) in tumors renal tumors renal mass protocol and had confirmed pathological diagnosis of either oncocytoma or RCC were included in the study. Enhancement readings were obtained for the tumor and the renal cortex using the same slice simultaneously. Our cohort involved 69 patients (46 men, 23 women; mean age 66) who presented with 79 renal masses. Histopathologically 40 were clear cell, 22 papillary, 5 chromophobe RCC and 12 oncocytoma. On the arterial, venous and delayed phase images, oncocytoma showed the highest mean enhancement change, i.e.,546, 396 and 239% followed by clear cell RCC 261, 261 and 174%, chromophobe RCC 147, 127 and 66% and papillary RCC 137, 184 and 118%, respectively. The enhancement pattern differed significantly on comparing oncocytoma with RCC (P oncocytoma, respectively. The enhancement and washout values in Hounsfield units obtained by multiphasic CT scan aid in distinguishing oncocytoma from the commonly seen subtypes of RCC in renal masses renal oncocytomas.

  12. The application of compressive sampling in rapid ultrasonic computerized tomography (UCT) technique of steel tube slab (STS)

    Science.gov (United States)

    Jiang, Baofeng; Jia, Pengjiao; Zhao, Wen; Wang, Wentao

    2018-01-01

    This paper explores a new method for rapid structural damage inspection of steel tube slab (STS) structures along randomly measured paths based on a combination of compressive sampling (CS) and ultrasonic computerized tomography (UCT). In the measurement stage, using fewer randomly selected paths rather than the whole measurement net is proposed to detect the underlying damage of a concrete-filled steel tube. In the imaging stage, the ℓ1-minimization algorithm is employed to recover the information of the microstructures based on the measurement data related to the internal situation of the STS structure. A numerical concrete tube model, with the various level of damage, was studied to demonstrate the performance of the rapid UCT technique. Real-world concrete-filled steel tubes in the Shenyang Metro stations were detected using the proposed UCT technique in a CS framework. Both the numerical and experimental results show the rapid UCT technique has the capability of damage detection in an STS structure with a high level of accuracy and with fewer required measurements, which is more convenient and efficient than the traditional UCT technique. PMID:29293593

  13. The reliability of Cavalier's principle of stereological method in determining volumes of enchondromas using the computerized tomography tools.

    Science.gov (United States)

    Acar, Nihat; Karakasli, Ahmet; Karaarslan, Ahmet; Mas, Nermin Ng; Hapa, Onur

    2017-01-01

    Volumetric measurements of benign tumors enable surgeons to trace volume changes during follow-up periods. For a volumetric measurement technique to be applicable, it should be easy, rapid, and inexpensive and should carry a high interobserver reliability. We aimed to assess the interobserver reliability of a volumetric measurement technique using the Cavalier's principle of stereological methods. The computerized tomography (CT) of 15 patients with a histopathologically confirmed diagnosis of enchondroma with variant tumor sizes and localizations was retrospectively reviewed for interobserver reliability evaluation of the volumetric stereological measurement with the Cavalier's principle, V = t × [((SU) × d) /SL]2 × Σ P. The volumes of the 15 tumors collected by the observers are demonstrated in Table 1. There was no statistical significance between the first and second observers ( p = 0.000 and intraclass correlation coefficient = 0.970) and between the first and third observers ( p = 0.000 and intraclass correlation coefficient = 0.981). No statistical significance was detected between the second and third observers ( p = 0.000 and intraclass correlation coefficient = 0.976). The Cavalier's principle with the stereological technique using the CT scans is an easy, rapid, and inexpensive technique in volumetric evaluation of enchondromas with a trustable interobserver reliability.

  14. An Anatomical Study of Maxillary-Zygomatic Complex Using Three-Dimensional Computerized Tomography-Based Zygomatic Implantation.

    Science.gov (United States)

    Xu, Xiangliang; Zhao, Shijie; Liu, Hui; Sun, Zhipeng; Wang, Jianwei; Zhang, Weiguang

    2017-01-01

    To obtain anatomical data of maxillary-zygomatic complex based on simulating the zygomatic implantation using cadaver heads and three-dimensional computerized tomography (3D-CT). Simulating zygomatic implantation was performed using seven cadaver heads and 3D-CT images from forty-eight adults. After measuring the maxillary-zygomatic complex, we analyzed the position between the implantation path and the maxillary sinus cavity as well as the distance between the implantation path and the zygomatic nerve. The distance from the starting point to the endpoint of the implant was 56.85 ± 5.35 mm in cadaver heads and 58.15 ± 7.37 mm in 3D-CT images. For the most common implantation path (80.20%), the implant went through the maxillary sinus cavity completely. The projecting points of the implant axis (IA) on the surface of zygoma were mainly located in the region of frontal process of zygomatic bone close to the lateral orbital wall. The distances between IA and zygomatic nerve in 53 sides were shorter than 2 mm. The simulating zygomatic implantation on cadaver skulls and 3D-CT imaging provided useful anatomical data of the maxillary-zygomatic complex. It is necessary to take care to avoid the zygomatic nerve injury during implantation, because it frequently appears on the route of implantation.

  15. Detection accuracy of proximal caries by phosphor plate and cone-beam computerized tomography images scanned with different resolutions.

    Science.gov (United States)

    Cheng, Jun-Ge; Zhang, Zhi-Ling; Wang, Xiao-Yan; Zhang, Zu-Yan; Ma, Xu-Chen; Li, Gang

    2012-08-01

    This study was carried out to assess whether the spatial resolution has an impact on the detection accuracy of proximal caries in flat panel CBCT (cone beam computerized tomography) images and if the detection accuracy can be improved by flat panel CBCT images scanned with high spatial resolution when compared to digital intraoral images. The CBCT test images of 45 non-restored human permanent teeth were respectively scanned with the ProMax 3D and the DCT Pro scanners at different resolutions. Digital images were obtained with a phosphor plate imaging system Digora Optime. Eight observers evaluated all the test images for carious lesion within the 90 proximal surfaces. With the histological examination serving as the reference standard, observer performances were evaluated by receiver operating characteristic (ROC) curves. The areas under the ROC curves were analyzed with two-way analysis of variance. No significant differences were found among the CBCT images and between CBCT and digital images when only proximal enamel caries was detected (p = 0.989). With respect to the detection of proximal dentinal caries, significant difference was found between CBCT and digital images (p proximal caries in flat panel CBCT images. The flat panel CBCT images scanned with high spatial resolution did not improve the detection accuracy of proximal enamel caries compared to digital intraoral images. CBCT images scanned with high spatial resolutions could not be used for proximal caries detection.

  16. A high-resolution computed tomography-based scoring system to differentiate the most infectious active pulmonary tuberculosis from community-acquired pneumonia in elderly and non-elderly patients

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, Jun-Jun [Ditmanson Medical Foundation Chia-Yi Christian Hospital, Section of Thoracic Imaging, Department of Chest Medicine and Family Medicine, Chiayi City (China); Chia Nan University of Pharmacy and Science, Tainan (China); Meiho University, Pingtung (China); Pingtung Christian Hospital, Pingtung (China); Chen, Solomon Chih-Cheng; Chen, Cheng-Ren [Ditmanson Medical Foundation Chia-Yi Christian Hospital, Department of Medical Research, Chiayi City (China); Yeh, Ting-Chun; Lin, Hsin-Kai; Hong, Jia-Bin; Wu, Bing-Tsang [Ditmanson Medical Foundation Chia-Yi Christian Hospital, Department of Family Medicine, Chiayi City (China); Wu, Ming-Ting [Department of Radiology, Kaohsiung Veterans General Hospital, Section of Thoracic and Circulation Imaging, Kaohsiung (China); School of Medicine, National Yang Ming University, Faculty of Medicine, Taipei (China)

    2014-10-15

    The objective of this study was to use high-resolution computed tomography (HRCT) imaging to predict the presence of smear-positive active pulmonary tuberculosis (PTB) in elderly (at least 65 years of age) and non-elderly patients (18-65 years of age). Patients with active pulmonary infections seen from November 2010 through December 2011 received HRCT chest imaging, sputum smears for acid-fast bacilli and sputum cultures for Mycobacterium tuberculosis. Smear-positive PTB was defined as at least one positive sputum smear and a positive culture for M. tuberculosis. Multivariate logistic regression analyses were performed to determine the HRCT predictors of smear-positive active PTB, and a prediction score was developed on the basis of receiver operating characteristic curve analysis. Of 1,255 patients included, 139 were diagnosed with smear-positive active PTB. According to ROC curve analysis, the sensitivity, specificity, positive predictive value, negative predictive value, false positive rates and false negative rates were 98.6 %, 95.8 %, 78.5 %, 99.8 %, 4.2 % and 1.4 %, respectively, for diagnosing smear-positive active PTB in elderly patients, and 100.0 %, 96.9 %, 76.5 %, 100.0 %, 3.1 % and 0.0 %, respectively, for non-elderly patients. HRCT can assist in the early diagnosis of the most infectious active PTB, thereby preventing transmission and minimizing unnecessary immediate respiratory isolation. (orig.)

  17. High-resolution computed tomography versus chest radiography in the diagnosis of interstitial lung disease in systemic sclerosis; Avaliacao da tomografia de alta resolucao versus radiografia de torax na doenca intersticial pulmonar na esclerose sistemica

    Energy Technology Data Exchange (ETDEWEB)

    Azevedo, Ana Beatriz Cordeiro de; Calderaro, Debora; Moreira, Caio [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Hospital das Clinicas. Servico de Reumatologia; Guimaraes, Silvana Mangeon Meirelles [Gerais Univ., Belo Horizonte, MG (Brazil). Hospital das Clinicas. Secao de Tomografia Computadorizada; Tavares Junior, Wilson Campos; Leao Filho, Hilton Muniz; Andrade, Diego Correa de [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Hospital das Clinicas. Servico de Radiologia e Diagnostico por Imagem]. E-mail: wilsontavaresjrmd@yahho.fr; Ferreira, Cid Sergio; Vieira, Jose Nelson Mendes [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Faculdade de Medicina. Dept. de Radiologia

    2005-04-01

    Objective: To compare the accuracy of high-resolution computed tomography (HRCT) with chest radiography in the diagnosis of interstitial lung disease in systemic sclerosis (SSc). Materials And Methods: HRCT scans and chest radiographs in postero-anterior and lateral views were performed in 34 patients with systemic sclerosis, according to the American College of Rheumatology preliminary criteria for the diagnosis of SSc. The prevalence of radiological findings suggestive of interstitial lung disease in SSc seen on both imaging methods was compared. Results: Interstitial disease was observed on HRCT images of 31 patients (91%) and in the chest radiographs of 16 patients (47%). The most frequent findings observed on HRCT were septal lines (74%), honeycombing (56%) and parenchymal bands (26%). Chest radiographs showed reticular areas of attenuation in 11 patients (32%) and parenchymal distortion in 12% of the patients. In 18 patients (53%) with normal chest radiographs HRCT showed septal lines in 55%, ground glass in 44%, honeycombing in 38.5% and cysts in 33%. Conclusion: HRCT is more sensitive than chest radiography in the evaluation of incipient interstitial lung involvement in patients with SSc and can provide a justification for immunosuppressive therapy in patients with early disease. (author)

  18. Computerized tomography technique for reconstruction of obstructed phase data in shearography.

    Science.gov (United States)

    Hung, Y Y; Huang, Y H; Liu, L; Ng, S P; Chen, Y S

    2008-06-10

    Shearography is an interferometric method that overcomes several limitations of holography by eliminating the reference beam. It greatly simplifies the optical setup and has much higher tolerance to environmental disturbances. Consequently, the technique has received considerable industrial acceptance, particularly for nondestructive testing. Shearography, however, is generally not applicable to the measurement of an obstructed area, as the area to be measured must be accessible to both illumination and imaging. We present an algorithm based on the principle of tomography that permits the reconstruction of the unavailable phase distribution in an obstructed area from the measured boundary phase distribution. In the process, a set of imaginary rays is projected from many different directions across the area. For each ray, integration of the phase directional derivative along the ray is equal to the phase difference between the boundary points intercepted by the ray. Therefore, a set of linear equations can be established by considering the multiple rays. Each equation expresses the unknown phase derivatives in the obstructed area in terms of the measured boundary phase. Solution of the set of simultaneous equations yields the unknown phase distribution in the blind area. While its applications to shearography are demonstrated, the technique is potentially applicable to all full-field optical measurement techniques such as holography, speckle interferometry, classical interferometry, thermography, moiré, photoelasticity, and speckle correlation techniques.

  19. Signs and symptoms after temporomandibular joint washing and cannula placement assessed by cone beam computerized tomography.

    Science.gov (United States)

    Kristensen, Kasper Dahl; Stoustrup, Peter; Alstergren, Per; Küseler, Annelise; Herlin, Troels; Pedersen, Thomas Klit

    2015-08-01

    Analyses of temporomandibular joint synovial fluid using the hydroxocobalamin push-pull technique are increasingly used. However, objective complications and subjective experiences from this procedure have not been described. Firstly, this study aimed to describe discomfort and potential side-effects of this method with special emphasis on symptoms related to the arthrocentesis to be used for future patient information and Ethical Committee applications. Secondly, this study aimed to evaluate the use of cone beam computed tomography (CBCT) as control of intra-capsular cannula placement. Twenty healthy, young adult volunteers were included. Extensive objective and subjective questionnaires were completed before and 14 days after the synovial fluid sampling. With the cannula inside the joints a CBCT was done to investigate if this procedure can be used to verify intra-capsular cannula position. The subjective findings: Most subjects did experience mild pain or discomfort post-operatively. In 12 of 20 subjects symptoms had resolved after 2 days and no subjects had symptoms for more than a week. The longer lasting symptoms were mainly transient joint sounds on mandibular movement. Objective findings: 14 days after the sampling mandibular protrusion had improved 1 mm, but all other objective measures were equal compared to baseline. CBCT showed a large variation in cannula position and no conclusions could be drawn from this. The hydroxocobalamin push-pull synovial fluid sampling may cause minor, transient symptoms. CBCT does not seem to provide any clinical benefits concerning the correct cannula position in relation to the upper joint compartment and disc.

  20. [The diagnostic value of computerized tomography in mediastinal diseases depending on their localization].

    Science.gov (United States)

    Sommer, B; Doppman, J L; Stelter, W; Mayr, B; Rienmüller, R; Lissner, J

    1981-04-01

    The diagnostic ranking and importance of computerised tomography was examined in 116 patients with abnormal findings in the mediastinal region, and was compared with conventional, non-invasive x-ray examinations. This method also yielded significant CT-specific additional information in the anterior mediastinum in 74.4% of the cases, in the mesomediastinum in 69.1%, in the posterior mediastinum in 79.2% in the upper thoracic aperture in 94.4% and in the paracardial region in 100% of the cases. The hilar region is an exception; in 68.8% of the cases, both methods were rated equal, whereas in 28.1% of the cases assessment via the CT method was even inferior. The specific additional information furnished by the CT method justifies a wider application of CT in solving the following problems concerning the mediastinum. -- clarification of a suspected but not yet established space-occupying growth in the mediastinum, before using invasive diagnostic methods such as mediastinoscopy and angiography; -- staging of an already identified primary mediastinal tumor of malignant lymphoma; -- in case of suspected changes in the large mediastinal vessels before employing angiography; -- on-target in the following diseases: bronchogenic carcinoma (because of improved pretherapeutic staging according to the TNM system), myasthenia gravis and identification of thymoma, hyperparathyroidism with suspected dystopic parathyroid glands.

  1. Maxillofacial injuries among trauma patients undergoing head computerized tomography; A Ugandan experience.

    Science.gov (United States)

    Krishnan, Ullas Chandrika; Byanyima, Rosemary Kusaba; Faith, Ameda; Kamulegeya, Adriane

    2017-01-01

    The aim of this study was to investigate epidemiological features of maxillofacial fractures within trauma patients who had head and neck computed tomography (CT) scan at the Mulago National referral hospital. CT scan records of trauma patients who had head scans at the Department of Radiology over 1-year period were accessed. Data collected included sociodemographic factors, type and etiology of injury, and concomitant maxillofacial injuries. A total of 1330 trauma patients underwent head and neck CT scan in the 1-year study period. Out of these, 130 were excluded due to incomplete or unclear records and no evidence of injury. Of the remaining 1200, 32% (387) had maxillofacial fractures. The median age of the patients with maxillofacial fractures was 28 (range = 18-80) years and 18-27 age group was most common at 47.5%. Road traffic accidents constituted 49.1% of fractures. The single most affected isolated bone was the frontal bone (23%). The number of maxillofacial bones fractured was predicted by age group (df = 3 F = 5.358, P = 0.001), association with other fractures (df = 1 F = 5.317, P = 0.03). Good matched case-control prospective studies are needed to enable us tease out the finer difference in the circumstances and pattern of injury if we are to design appropriate preventive measures.

  2. Computerized Tomography-Guided Stereotactic Biopsy of Intracranial Lesions: Report of 500 Consecutive Cases.

    Science.gov (United States)

    Can, Songul Meltem; Turkmenoglu, Osman Nuri; Tanik, Canan; Uysal, Ender; Ozoner, Baris; Kaldirimoglu, Saime Ayca; Musluman, Ahmet Murat; Yilmaz, Adem; Cavusoglu, Halit; Bayindir, Cicek; Aydin, Yunus

    2017-01-01

    Computed tomography (CT)-guided stereotactic brain biopsy has been performed in our clinic since March 1998. In this prospective study, we examined the patient data undergoing stereotactic biopsy and the results of biopsies in 500 consecutive patients. Between the dates of March 1998 and January 2015, CT-guided stereotactic biopsies were performed by using the Leksell stereotactic frame system (Elekta Instruments EU, Sweden) in 500 patients. A total of 512 procedures were performed in patients consisting of 184 females (36.8%) and 316 males (63.2%), ages ranging from 3 to 81 years (mean 50.40±16.67). Conclusive histopathological diagnosis was not achieved in 17(3.3%) of 512 procedures. Of the others, 173 (33.8%) were high-grade gliomas, 103 (20.1%) were low-grade gliomas, 36 (7%) were malignant lymphomas, 34 (6.6%) were other types of brain tumors, 82 (16%) were metastasis and 67 (13.1%) were non-tumoral lesions. Complications were occurred in ten cases: 3 tumoral bleedings, 2 hypertensive cerebral hematomas, 2 peroperative convulsions, 1 epidural hematoma, 1 myocardial infarction and 1 brain edema. The patients who developed myocardial infarction and hypertensive thalamic hematoma died. The mortality was 0.4% and morbidity was 1.6% in 512 procedures. CT-guided stereotactic biopsy is a reliable and a safe procedure in cases with intracranial lesions when histopathological diagnosis is required for the appropriate treatment.

  3. Image Quality in Oncologic Chest Computerized Tomography With Iterative Reconstruction: A Phantom Study.

    Science.gov (United States)

    Jensen, Kristin; Aaløkken, Trond Mogens; Tingberg, Anders; Fosse, Erik; Martinsen, Anne Catrine T

    2016-01-01

    The purpose of this study was to validate iterative reconstruction technique in oncologic chest computed tomography (CT). An anthropomorphic thorax phantom with 4 simulated tumors was scanned on a 64-slice CT scanner with 2 different iterative reconstruction techniques: one model based (MBIR) and one hybrid (ASiR). Dose levels of 14.9, 11.1, 6.7, and 0.6 mGy were used, and all images were reconstructed with filtered back projection (FBP) and both iterative reconstruction algorithms. Hounsfield units (HU) and absolute noise were measured in the tumors, lung, heart, diaphragm, and muscle. Contrast-to-noise ratios (CNRs) and signal-to-noise ratios (SNRs) were calculated. Model-based iterative reconstruction (MBIR) increased CNRs of the tumors (21.1-192.2) and SNRs in the lung (-49.0-165.6) and heart (3.1-8.5) at all dose levels compared with FBP (CNR, 1.1-23.0; SNR, -7.5-31.6 and 0.2-1.1) and with adaptive statistical iterative reconstruction (CNR, 1.2-33.2; SNR, -7.3-37.7 and 0.2-1.5). At the lowest dose level (0.6 mGy), MBIR reduced the cupping artifact (HU range: 17.0 HU compared with 31.4-32.2). An HU shift in the negative direction was seen with MBIR. Quantitative image quality parameters in oncologic chest CT are improved with MBIR compared with FBP and simpler iterative reconstruction algorithms. Artifacts at low doses are reduced. A shift in HU values was shown; thus, absolute HU values should be used with care.

  4. Utility of mobile devices in the computerized tomography evaluation of intracranial hemorrhage

    Directory of Open Access Journals (Sweden)

    Sridhar G Panughpath

    2013-01-01

    Full Text Available Aim: To evaluate the utility of a mobile device to detect and assess intracranial hemorrhage (ICH on head computed tomographys (CT performed in the emergency setting. Materials and Methods: 100 head CT scans were randomly selected from our emergency radiology database and anonymized for patient demographics and clinical history. The studies were independently interpreted by two experienced radiologists in a blinded manner, initially on a mobile device (iPad, Apple computers and subsequently, at an interval of one week, on a regular desktop workstation. Evaluation was directed towards detection, localization and characterization of hemorrhage. The results were assessed for accuracy, sensitivity, specificity and positive predictive value. Statistical significance was ascertained using Fisher′s exact test. Results: 27 of the examinations were positive for ICH, of which 11 had multiple hemorrhages. Of these there were 17 subdural, 18 intraparenchymal, 8 subarachnoid, 4 intraventricular and 2 extradural hemorrhages. In 96 of the studies there was complete concurrence between the iPad and desktop interpretations for both radiologists. Of 49 hemorrhages, 48 were accurately detected on the iPad by one of the radiologists. In the remaining case, a tiny intraventricular hemorrhage was missed by both radiologists on the iPad as well as on the workstation, indicating that the miss was more likely related to the very small size of the hemorrhage than the viewer used. Conclusion: We conclude that in the emergency setting, a mobile device with appropriate web-based pictue archiving and communication system (PACS is effective in the detection of intracranial hemorrhage present on head CT.

  5. Dose assessment in pediatric computerized tomography; Avaliacao de doses em tomografia computadorizada pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Vilarinho, Luisa Maria Auredine Lima

    2004-07-01

    The objective of this work was the evaluation of radiation doses in paediatric computed tomography scans, considering the high doses usually involved and the absence of any previous evaluation in Brazil. Dose values were determined for skull and abdomen examinations, for different age ranges, by using the radiographic techniques routinely used in the clinical centers investigated. Measurements were done using pencil shape ionization chambers inserted in polymethylmethacrylate (PMMA) phantoms. These were compact phantoms of different diameters were specially designed and constructed for this work, which simulate different age ranges. Comparison of results with published values showed that doses were lower than the diagnostic reference levels established to adults exams by the European Commission. Nevertheless, doses in paediatric phantoms were higher than those obtained in adult phantoms. The paediatric dose values obtained in Hospitals A and B were lower than the reference level (DRL) adopted by SHIMPTON for different age ranges. In the range 0 - 0.5 year (neonatal), the values of DLP in Hospital B were 94 por cent superior to the DRL For the 10 years old children the values of CTDI{sub w} obtained were inferior in 89 por cent for skull and 83 por cent for abdomen examinations, compared to the values published by SHRIMPTON and WALL. Our measured CTDI{sub w} values were inferior to the values presented for SHRIMPTON and HUDA, for all the age ranges and types of examinations. It was observed that the normalized dose descriptors values in children in the neonatal range were always superior to the values of doses for the adult patient. In abdomen examinations, the difference was approximately 90% for the effective dose (E) and of 57%.for CTDI{sub w} . (author)

  6. [Gunshot wounds of the cranium studied with computerized tomography. Personal experience in 23 cases].

    Science.gov (United States)

    Salzano, A; De Rosa, A; Scialpi, M; Rossi, E; Carbone, M; Brunese, L; Nocera, V; Muto, M

    2000-01-01

    Gunshot wounds to the head are usually mortal injuries. Their frequency has been increasing in the last years because of increasing crime rates. Gunshot wounds to the head require close clinical and diagnostic cooperation of the neurosurgeon and radiologist, detailed assessment of skull and brain damage, and finally prompt treatment. Emergency Computed Tomography (CT) makes a useful tool for depicting bullet course and brain damage, and thus helps plan treatment. We investigated the CT signs of subdural hematoma, lacerocontusive focus, subarachnoid hemorrhage, hemoencephalus, skull bone fracture and thecal hollow and report them as an aid to the neurosurgeon and the radiologist, for best treatment planning, and in an attempt to establish useful prognostic criteria. We retrospectively reviewed 23 cases of gunshot injuries to the head studied with CT at the Emergency Unit of Loreto Mare Hospital in Naples, Italy. Twenty patients were men and 3 women; their mean age was 31 years (range: 18-49). Three women and 2 men had been injured accidentally by wandering bullets, and one case was an attempted suicide; all the other cases resulted from shootings. CT slices were 10 mm thick, with 8 mm gap (5 mm in complex injuries and when posterior cranial fossa was involved); all scans were unenhanced. We found 22 penetrating gunshot wounds: 13 of them with thecal entry hole and intracranial bullet retention and 9 with an entry and an exit hole. One case was a superficial wound. Crash skull fractures were seen in 22 cases and they were fragmented in 12, with overlapping thecal fragments in 4, and with deep fragments in 2 cases. There were scattered bone splinters in 3 cases and the bullet was retained in the mastoid bone in one case. Lacerocontusive foci were assessed in 22 cases, brain swelling in 20, subarachnoid hemorrhage in 19, brain hematoma in 15, blood in the ventricular system in 9, pneumoencephalus in 7, air bubbles along the bullet course in 7, impression on ventricula

  7. A comparative analysis of periapical radiography and cone-beam computerized tomography for the evaluation of endodontic obturation length.

    Science.gov (United States)

    Cheng, Li; Zhang, Ru; Yu, Xuan; Tian, Yuanyuan; Wang, Hu; Zheng, Guangning; Hu, Tao

    2011-09-01

    The aim of this study was to determine the consistency and inconsistency between the periapical radiography (PR) and cone-beam computerized tomography (CBCT) in evaluating the length of root canal obturations (RCOs) in vivo. Thirty-six maxillary and mandibular first and second molars yielding 109 obturated root canals with available PR and CBCT images were analyzed. The inclusion criterion was that the RCO extended 0-2 mm short of the radiographic apex on PR images. Teeth having root canal calcification, apical resorption, or poor quality PR/CBCT images were excluded. Agreement and disagreement between the 2 imaging modalities for obturation length were analyzed using the χ(2) test. A total of 30.3% of the RCOs evaluated by PR as having adequate length were diagnosed by CBCT to have inadequate length. Among these, 13.8% were overextended and 16.5% underextended as diagnosed by CBCT. When the distance from the filling tip to the radiographic apex was 0.5 to 1 mm on the PR image, the discordance rate was the lowest (11.1%) in all evaluated distance groups, significantly lower than with distances of 0-0.5 mm and 1.5-2 mm (P lingual side, overextension was the main evaluation result by CBCT in the disagreement evaluation with PR and significantly more frequent than those at the mesial/distal/central side (P < .01). CBCT evaluated 30.3% of the RCOs with radiographically adequate length as inadequate. When the RCOs radiographically terminated 0.5-1 mm short of the apex, the evaluation rated adequate for obturation length was comparatively reliable. Copyright © 2011 Mosby, Inc. All rights reserved.

  8. Micro-computerized tomography assessment of fluorescence aided caries excavation (FACE) technology: comparison with three other caries removal techniques.

    Science.gov (United States)

    Zhang, X; Tu, R; Yin, W; Zhou, X; Li, X; Hu, D

    2013-12-01

    The aim of this study was to determine the caries removal effectiveness (CRE) and minimal invasiveness potential (MIP) of four dentine caries removal methods. After carious molars were scanned using micro-computerized tomography (micro-CT), dentine caries were removed by fluorescence aided caries excavation (FACE) technology, laser induced fluorescence (LIF), chemomechanical excavation (CME), and conventional excavation (CE). Micro-CT was then repeated. CRE was determined based on the volume of residual caries/initial caries (RC/IC) and the mean mineral density (MD) at the cavity floor. MIP was determined by measuring the volume of the prepared cavity/initial cavity (PC/IC). Among the four groups, the LIF group had the smallest RC/IC (0.08), the highest mean MD at the cavity floor (1.32 g/cm(3) ) and the highest MIP (4.47). The CME group had the highest RC/IC (0.24), the lowest mean MD (1.01 g/cm(3) ) and the lowest MIP (2.23). The CE group exhibited a more acceptable CRE (RC/IC = 0.13, mean MD = 1.21 g/cm(3) ) but had a higher MIP (3.95). Both the CRE and MIP parameters of FACE technology were the second most acceptable (RC/IC = 0.12, mean MD = 1.13 g/cm(3) , MIP = 3.20) and did not differ significantly from the most acceptable. FACE is an effective caries removal technology for removing infected dentine without significantly increasing cavity size. © 2013 Australian Dental Association.

  9. Computerized tomography in evaluation of decreased acetabular and femoral anteversion; Besonderheiten bei der Bestimmung der Hueftpfannenanteversion und Schenkelhalsantetorsion durch Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Toennis, D.; Skamel, H.J. [Institut fuer Strahlendiagnostik, Klinikum Dortmund GmbH (Germany)

    2003-09-01

    Computerized tomography has received a new importance. It has been shown that decreased anteversion of femur and acetabulum, when both have decreased angles, are causing pain and osteoarthritis of the hip joint. Operative treatment should be performed before osteoarthritis develops. Exact measurements therefore are necessary. The investigation should be performed in prone position to have the pelvis lying in a defined and normal position. Femoral torsion is measured between the transverse axis of the knee and the femoral neck. The transverse axis for measurement of the femoral anteversion is defined by a rectangular line to the sagittal plane. For evaluation of the femoral anteversion in total the angle of the condyles has to be added to the femoral neck angle when the knee is found in internal rotation. Acetabular anteversion should be measured at the level where the femoral head is still in full contact and congruence with the anterior margin of the acetabulum. (orig.) [German] Fuer die Computertomographie hat sich eine neue Aufgabe ergeben. Es hat sich gezeigt, dass verringerte Pfannenanteversion und Schenkelhalsantetorsion haeufige Ursachen von Hueftschmerz und -arthrose sind, v. a. wenn beide gegen 0 gehen. Da operative Massnahmen vor Eintreten der Arthrose ergriffen werden sollten, sind genaue Messwerte erforderlich. Die Untersuchung sollte in Bauchlage durchgefuehrt werden, um eine einheitliche und weitgehend normale Beckenkippung zu gewaehrleisten. Die Schenkelhalstorsion wird zwischen der Kniegelenk- und der Schenkelhalsachse gemessen. Zur Festlegung der Sagittalebene legt man am besten eine Mittellinie zwischen die Beckenschaufeln. Die Messung der Pfannenanteversion sollte in der Schnitthoehe erfolgen, wo die Bewegungseinschraenkung der Innenrotation auftritt. (orig.)

  10. [Application of spiral computerized tomography in the study of traumatic lesions of the thoracic aorta].

    Science.gov (United States)

    Mengozzi, E; Burzi, M; Miceli, M; Lipparini, M; Sartoni Galloni, S

    2000-09-01

    Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. We investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. We compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. All patients underwent a plain chest radiograph in supine recumbency when admitted to the Emergency Room. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed with no intravenous contrast agent administration and the pitch 2 technique. After a previous baseline study, contrast-enhanced scans were acquired with pitch 1 in 87 patients. All examinations were assessed for the presence of mediastinal hematoma, periaortic hematoma, traumatic pseudodiverticulum, irregular aortic wall or contour and intimal flap as signs of aortic rupture. Helical CT showed thoracic aortic lesions in 9 of 256 patients examined. In all the 9 cases we found a mediastinal hematoma and all of them had positive plain chest radiographic findings of mediastinal enlargement. Moreover, in 6 cases aortic knob blurring was also evident on plain chest film and in 5 cases depressed left mainstem bronchus and trachea deviation rightwards were observed. All aortic lesions were identified on axial scans and located at the isthmus of level. Aortic rupture was always depicted as pseudodiverticulum of the proximal descending tract and intimal flap. We also found periaortic hematoma in 6 cases

  11. Lung scintigraphy with nonspecific human immunoglobulin G ({sup 99m}Tc-HIG) in the evaluation of pulmonary involvement in connective tissue diseases: correlation with pulmonary function tests (PFTs) and high-resolution computed tomography (HRCT)

    Energy Technology Data Exchange (ETDEWEB)

    Kostopoulos, C.; Toubanakis, C.; Mamoulakis, C.; Gialafos, E.; Mavrikakis, M. [Alexandra University Hospital, Department of Clinical Therapeutics, Athens (Greece); Koutsikos, J.; Zerva, C.; Leondi, A. [Alexandra University Hospital, Department of Nuclear Medicine, Athens (Greece); Moulopoulos, L.A. [Areteion University Hospital, Department of Radiology, Athens (Greece); Sfikakis, P.P. [Laikon University Hospital, Department of Propaedeutic Medicine, Athens (Greece)

    2008-02-15

    In patients with connective tissue diseases (CTD), the early detection and evaluation of the severity of the pulmonary involvement is mandatory. High-resolution computed tomography (HRCT) and pulmonary function tests (PFTs) are considered to be valuable noninvasive diagnostic modalities. Radiopharmaceuticals have also been used for this purpose. Our aim was the evaluation of technetium-labeled human polyclonal immunoglobulin G (HIG) lung scintigraphy in the early detection and assessment of the severity of the pulmonary involvement in CTD patients. Fifty-two nonsmoking CTD patients were studied by PFTs, HRCT, and HIG. According to PFTs, patients were divided in group A (impaired PFTs - abnormal pulmonary function) and group B (normal pulmonary function). Semiquantitative analysis was done on HIG and HRCT and corresponding scores were obtained. Significant difference was found between HIG scores in the two groups (0.6 {+-} 0.07 vs 0.51 {+-} 0.08, P < 0.001). There was a statistically significant negative correlation between HIG scores and PFTs results and a positive correlation between HIG and HRCT scores. HIG demonstrated similar clinical performance to HRCT. At the best cut-off levels of their score (0.56 and 7, respectively), HIG had a superior sensitivity (77.5 vs 57.5%) with lower specificity (75 vs 91.7%). The combination of the two methods increased the sensitivity of abnormal findings at the expense of specificity. HIG scintigraphy can be used in the early detection and evaluation of the severity of the pulmonary involvement in CTD, whereas, when used in combination with HRCT, the detection of affected patients can be further improved. (orig.)

  12. Efficacy of 18F-2-fluoro-2-deoxy-D-glucose Positron Emission Tomography/Computerized Tomography for Bone Marrow Infiltration Assessment in the Initial Staging of Lymphoma

    Directory of Open Access Journals (Sweden)

    Ali Ozan Öner

    2017-06-01

    Full Text Available Objective: Currently 18F-2-fluoro-2-deoxy-D-glucose (18F-FDG positron emission tomography/computerized tomography (PET/CT is being successfully used for staging and follow-up of Hodgkin’s lymphoma (HL and non-Hodgkin’s lymphoma (NHL. Various studies have demonstrated that PET/CT effectively detects bone marrow involvement (BMI and is concordant with bone marrow biopsy (BMB findings, thus it is deemed as a complementary method. This study was aimed to evaluate18F-FDG-PET/CT efficiency for detection of BMI in HL and NHL. Methods: The study included 172 lymphoma cases who were admitted to Akdeniz University Medical School Department of Nuclear Medicine for initial staging with PET/CT. Visual and semiquantitative assessments were performed for PET/CT scan findings of the cases. The maximum standard uptake (SUVmax value was the quantitative parameter used for 18F-FDG-PET scan. In visual assessment, bone marrow metabolic activity that is greater than the liver was considered as pathologic. For semiquantitative assessment, regions of interest were drawn for SUVmax estimation, which included iliac crest in cases with diffusely increased metabolic activity and the highest activity area in cases with focal involvement. BMB was considered as the reference test. Results: On visual assessment of all the cases, PET/CT was found to yield 31% sensitivity and 85% specificity rate for detection of BMI. On visual assessment of HL cases, sensitivity rate was determined as 80%, and specificity as 78%, while in NHL cases the corresponding values were 24% and 90%, respectively. On semiquantitative assessment of HL cases, considering SUVmax≥4, sensitivity was found as 80% and specificity as 68%. In NHL patients, considering SUVmax≥3.2, sensitivity rate was detected as 65% and specificity as 58%. Conclusion: In this study, a moderately high concordance was observed between PET/CT and BMB findings. PET/CT appears to be a significant method for detecting BMI

  13. Limiting liability via high resolution image processing

    Energy Technology Data Exchange (ETDEWEB)

    Greenwade, L.E.; Overlin, T.K.

    1996-12-31

    The utilization of high resolution image processing allows forensic analysts and visualization scientists to assist detectives by enhancing field photographs, and by providing the tools and training to increase the quality and usability of field photos. Through the use of digitized photographs and computerized enhancement software, field evidence can be obtained and processed as `evidence ready`, even in poor lighting and shadowed conditions or darkened rooms. These images, which are most often unusable when taken with standard camera equipment, can be shot in the worst of photographic condition and be processed as usable evidence. Visualization scientists have taken the use of digital photographic image processing and moved the process of crime scene photos into the technology age. The use of high resolution technology will assist law enforcement in making better use of crime scene photography and positive identification of prints. Valuable court room and investigation time can be saved and better served by this accurate, performance based process. Inconclusive evidence does not lead to convictions. Enhancement of the photographic capability helps solve one major problem with crime scene photos, that if taken with standard equipment and without the benefit of enhancement software would be inconclusive, thus allowing guilty parties to be set free due to lack of evidence.

  14. Some aspects of evaluation of image quality in computerized tomography; Alguns aspectos da avaliacao da qualidade da imagem em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Travassos, Paulo Cesar Baptista; Peixoto, Jose Guilherme; Almeida, Carlos Eduardo Veloso de, E-mail: pctravassos@gmail.com [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Campos, Luciana Tourinho; Magalhaes, Luis Alexandre [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2016-07-01

    The evaluation of CT scanners image quality includes measuring the Hounsfield values, HU, using a table with the limit values. This table does not consider that different devices have different effective energies, which may cause some false results. The evaluation of 90 computerized tomography, by the American College Radiology methodology, showed that some failed devices in the evaluation showed excellent linear fit between the values of the linear attenuation coefficients calculated for the actual energy used, according to the HU values. The analysis of the coefficient of determination suggests that 10 of these devices could have been approved. (author)

  15. Quantification of Soil Physical Properties by Using X-Ray Computerized Tomography (CT) and Standard Laboratory (STD) Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Maria Ambert [Iowa State Univ., Ames, IA (United States)

    2003-12-12

    The implementation of x-ray computerized tomography (CT) on agricultural soils has been used in this research to quantify soil physical properties to be compared with standard laboratory (STD) methods. The overall research objective was to more accurately quantify soil physical properties for long-term management systems. Two field studies were conducted at Iowa State University's Northeast Research and Demonstration Farm near Nashua, IA using two different soil management strategies. The first field study was conducted in 1999 using continuous corn crop rotation for soil under chisel plow with no-till treatments. The second study was conducted in 2001 and on soybean crop rotation for the same soil but under chisel plow and no-till practices with wheel track and no-wheel track compaction treatments induced by a tractor-manure wagon. In addition, saturated hydraulic (K{sub s}) conductivity and the convection-dispersion (CDE) model were also applied using long-term soil management systems only during 2001. The results obtained for the 1999 field study revealed no significant differences between treatments and laboratory methods, but significant differences were found at deeper depths of the soil column for tillage treatments. The results for standard laboratory procedure versus CT method showed significant differences at deeper depths for the chisel plow treatment and at the second lower depth for no-till treatment for both laboratory methods. The macroporosity distribution experiment showed significant differences at the two lower depths between tillage practices. Bulk density and percent porosity had significant differences at the two lower depths of the soil column. The results obtained for the 2001 field study showed no significant differences between tillage practices and compaction practices for both laboratory methods, but significant differences between tillage practices with wheel track and no-wheel compaction treatments were found along the soil

  16. Investigating the effect of characteristic x-rays in cadmium zinc telluride detectors under breast computerized tomography operating conditions.

    Science.gov (United States)

    Glick, Stephen J; Didier, Clay

    2013-10-14

    A number of research groups have been investigating the use of dedicated breast computerized tomography (CT). Preliminary results have been encouraging, suggesting an improved visualization of masses on breast CT as compared to conventional mammography. Nonetheless, there are many challenges to overcome before breast CT can become a routine clinical reality. One potential improvement over current breast CT prototypes would be the use of photon counting detectors with cadmium zinc telluride (CZT) (or CdTe) semiconductor material. These detectors can operate at room temperature and provide high detection efficiency and the capability of multi-energy imaging; however, one factor in particular that limits image quality is the emission of characteristic x-rays. In this study, the degradative effects of characteristic x-rays are examined when using a CZT detector under breast CT operating conditions. Monte Carlo simulation software was used to evaluate the effect of characteristic x-rays and the detector element size on spatial and spectral resolution for a CZT detector used under breast CT operating conditions. In particular, lower kVp spectra and thinner CZT thicknesses were studied than that typically used with CZT based conventional CT detectors. In addition, the effect of characteristic x-rays on the accuracy of material decomposition in spectral CT imaging was explored. It was observed that when imaging with 50-60 kVp spectra, the x-ray transmission through CZT was very low for all detector thicknesses studied (0.5-3.0 mm), thus retaining dose efficiency. As expected, characteristic x-ray escape from the detector element of x-ray interaction increased with decreasing detector element size, approaching a 50% escape fraction for a 100 μm size detector element. The detector point spread function was observed to have only minor degradation with detector element size greater than 200 μm and lower kV settings. Characteristic x-rays produced increasing distortion

  17. [Aging changes of the root canal morphology in maxillary first premolars observed by cone-beam computerized tomography].

    Science.gov (United States)

    Hu, R C; Cao, L L; Xie, W; Hu, Y Q; Piao, Z G

    2016-04-09

    To observe the morphological changes of root canals with aging in maxillary first premolars by using cone-beam computerized tomography(CBCT)in order to facilitate endodontic management of root canals in various aged patients. The digital CBCT data of the maxillary first premolars in 405 cases from the patients in Oral Medical Center of The First Affiliated Hospital, Jinan University from March 2011 to June 2015 were collected. The CBCT images were divided into 6 groups according to the patients' ages: groups 11-20, 21-30, 31-40, 41-50, 51-60 and >60 years-olds, respectively. Changes of morphologies of root canals with aging including such parameters as types of the root canal, incidence of double root canals in single rooted teeth, distance between both root canal orifices of double rooted canals, and morphological change of the cross section of roots. Chi-square test and liner trend test were adopted in statistical analysis in the present study. The distribution of various types of the root canals were significantly different amongst various aged groups(Paging, the percentages of type Ⅰ and type Ⅲ decreased while type Ⅱ increased. However, there were no remarkable changes of type Ⅳ observed. The incidence of double rooted canals in single rooted teeth gradually increased with aging especially in 20-years-old and above groups, e.g. 51.7%(31/60)in group 11-20 years-olds and 83.0%(44/53)in group 21-30 years-olds. However, there was no significant increase observed after the age of 40. The distance between both root canal orifices of double rooted canals became shorter with aging except in groups of 40-years-olds and above. The morphologies of the cross sections in most aged groups were flat shaped(1 020/2 105, 48.5%)and oval shape(594/2 105, 28.2%). Along with aging, the percentage of circular shape gradually increased while flat and oval shapes decreased. The morphology of root canal could be clearly showed by the CBCT images. The change of morphologies of

  18. The use of computerized tomography in pediatrics: risk of radiation; Actualizacion de temas relacionados con elriesgo de radiacion y la obtencion de imagenes pediatricas por tomografia computerizada

    Energy Technology Data Exchange (ETDEWEB)

    Lane, F.; Donnelly, M. D.

    2004-07-01

    The use of computerized tomography in paediatrics is rapidly increasing and with that the dose received by the patients. Recent publications show that the new technique is overused and therefore the cancer risk is increasing in paediatric patients. The article discusses the strategies in use ro reduce the radiation doses without losing the advantages of the new technique. Paediatric doses can be reduced adjusting the photon beam to the density and dimensions of the paediatric patient, in new equipment modulating automatically the current and the tension in the cathodic tube to the optimum values without impairing the quality of the image. Dose can also be reduce increasing the rotation velocity and the pitch of the gantry, limiting the exploration to the region of interest and using shielding to protect the most sensitive tissues. Nevertheless, the article defends the prudent use of computerised tomography and recommends, whenever possible, the use of complementary non ionizing radiation techniques. (Author) 26 refs.

  19. Preoperative Computerized Tomography and Magnetic Resonance Imaging of the Pancreas Predicts Pancreatic Mass and Functional Outcomes After Total Pancreatectomy and Islet Autotransplant.

    Science.gov (United States)

    Young, Michael C; Theis, Jake R; Hodges, James S; Dunn, Ty B; Pruett, Timothy L; Chinnakotla, Srinath; Walker, Sidney P; Freeman, Martin L; Trikudanathan, Guru; Arain, Mustafa; Robertson, Paul R; Wilhelm, Joshua J; Schwarzenberg, Sarah J; Bland, Barbara; Beilman, Gregory J; Bellin, Melena D

    2016-08-01

    Approximately two thirds of patients will remain on insulin therapy after total pancreatectomy with islet autotransplant (TPIAT) for chronic pancreatitis. We investigated the relationship between measured pancreas volume on computerized tomography or magnetic resonance imaging and features of chronic pancreatitis on imaging, with subsequent islet isolation and diabetes outcomes. Computerized tomography or magnetic resonance imaging was reviewed for pancreas volume (Vitrea software) and presence or absence of calcifications, atrophy, and dilated pancreatic duct in 97 patients undergoing TPIAT. Relationship between these features and (1) islet mass isolated and (2) diabetes status at 1-year post-TPIAT were evaluated. Pancreas volume correlated with islet mass measured as total islet equivalents (r = 0.50, P < 0.0001). Mean islet equivalents were reduced by more than half if any one of calcifications, atrophy, or ductal dilatation were observed. Pancreatic calcifications increased the odds of insulin dependence 4.0 fold (1.1, 15). Collectively, the pancreas volume and 3 imaging features strongly associated with 1-year insulin use (P = 0.07), islet graft failure (P = 0.003), hemoglobin A1c (P = 0.0004), fasting glucose (P = 0.027), and fasting C-peptide level (P = 0.008). Measures of pancreatic parenchymal destruction on imaging, including smaller pancreas volume and calcifications, associate strongly with impaired islet mass and 1-year diabetes outcomes.

  20. Computerized tomography-guided sphenopalatine ganglion pulsed radiofrequency treatment in 16 patients with refractory cluster headaches: Twelve- to 30-month follow-up evaluations.

    Science.gov (United States)

    Fang, Luo; Jingjing, Lu; Ying, Shen; Lan, Meng; Tao, Wang; Nan, Ji

    2016-02-01

    Sphenopalatine ganglion percutaneous radiofrequency thermocoagulation treatment can improve the symptoms of cluster headaches to some extent. However, as an ablation treatment, radiofrequency thermocoagulation treatment also has side effects. To preliminarily evaluate the efficacy and safety of a non-ablative computerized tomography-guided pulsed radiofrequency treatment of sphenopalatine ganglion in patients with refractory cluster headaches. We included and analysed 16 consecutive cluster headache patients who failed to respond to conservative therapy from the Pain Management Center at the Beijing Tiantan Hospital between April 2012 and September 2013 treated with pulsed radiofrequency treatment of sphenopalatine ganglion. Eleven of 13 episodic cluster headaches patients and one of three chronic cluster headaches patient were completely relieved of the headache within an average of 6.3 ± 6.0 days following the treatment. Two episodic cluster headache patients and two chronic cluster headache patients showed no pain relief following the treatment. The mean follow-up time was 17.0 ± 5.5 months. All patients enrolled in this study showed no treatment-related side effects or complications. Our data show that patients with refractory episodic cluster headaches were quickly, effectively and safely relieved from the cluster period after computerized tomography-guided pulsed radiofrequency treatment of sphenopalatine ganglion, suggesting that it may be a therapeutic option if conservative treatments fail. © International Headache Society 2015.

  1. Computerized tomography dose index weighted comparison between two groups of computer tomography equipment; Comparacao do indice de dose em tomografia computadorizada - ponderado (CTDI{sub W}) entre dois grupos de equipamentos de tomografia

    Energy Technology Data Exchange (ETDEWEB)

    Capeleti, Felipe F., E-mail: fcapeleti@gmail.co [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil); Nersissian, Denise Y.; Furquim, Tania A.C. [Universidade de Sao Paulo (IEE/USP), SP (Brazil). Inst. de Eletrotecnica e Energia

    2010-07-01

    This work intended to compare the results of the Computerized Tomography Dose Index (CTDI) between the head and abdomen protocols for different equipment configurations: the first group was composed by equipment with 10 up to 16 slices, the second group presented 40 up to 320 slices detectors. The results has shown variation higher than 20 % for both protocols of the group 1 and variation of 14.5 % and 7.3 %, in group 2, for head and abdomen protocols, respectively. Although having different slices configurations, the other comparison between both groups has shown similar dose impartation to the patients, considering the associated uncertainties with this measurement. (author)

  2. Regional cerebral blood flow during rest and skilled hand movements by xenon-133 inhalation and emission computerized tomography

    DEFF Research Database (Denmark)

    Lauritzen, M; Henriksen, L; Lassen, N A

    1981-01-01

    Regional cerebral blood flow (CBF) was studied in 16 normal adult volunteers during rest and in 10 the study was repeated during skilled hand movements. A fast-rotating ("dynamic"), single-photon emission computerized tomograph (ECT) with four detector heads was used. Xenon-133 was inhaled over a 1...

  3. pattern of interstitial lung disease as seen by high resolution

    African Journals Online (AJOL)

    2012-09-01

    Sep 1, 2012 ... Background: Diffuse lung diseases constitute a major cause of morbidity and mortality worldwide. High Resolution Computed Tomography (HRCT) is the recommended imaging technique in the diagnosis, assessment and followup of these diseases. Objectives: To describe the pattern of HRCT findings in ...

  4. Epiploic appendicitis and omental infarction. Findings in the ultrasonography and computerized tomography; Apendicitis epiploica e infarto omental. Hallazgos en ecografia y tomografia computarizada

    Energy Technology Data Exchange (ETDEWEB)

    Migule, A.; Ripolles, T.; Martinez, M. J.; Morote, V.; Ruiz, A. [Hospital Universitario Dr. Peset. Valencia (Spain)

    2001-07-01

    Describe the findings in the ultrasonography and computerized tomography (CT) of the omental infarction and epiploic appendicitis. The clinical and radiological findings of the patients diagnosed in our hospital with epiploic appendicitis or omental infarctions between August 1994 and March 2001 were assessed retrospectively. We found a high incidence (42 cases) of these two diseases: 30 patients with diagnosis of epiploic appendicitis and 12 with the diagnosis of omental infarction. Four patients were treated surgically, while the remaining 38 were conservatively, without posterior complications. The ultrasonography and CT images is characteristics. making it possible to make a diagnosis of epiploic appendicitis or omental infarction with certainty. It is not necessary to make a differential diagnosis between the two entities because their prognosis and treatment are similar. Their incidence is much more frequent than that previously published. (Author) 19 refs.

  5. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography; Avaliacao dos diametros normais da aorta toracica e abdominal pela tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, Claudio Luiz

    1995-07-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  6. High-resolution multiphoton cryomicroscopy.

    Science.gov (United States)

    König, Karsten; Uchugonova, Aisada; Breunig, Hans Georg

    2014-03-15

    An ultracompact high-resolution multiphoton cryomicroscope with a femtosecond near infrared fiber laser has been utilized to study the cellular autofluorescence during freezing and thawing of cells. Cooling resulted in an increase of the intracellular fluorescence intensity followed by morphological modifications at temperatures below -10 °C, depending on the application of the cryoprotectant DMSO and the cooling rate. Furthermore, fluorescence lifetime imaging revealed an increase of the mean lifetime with a decrease in temperature. Non-destructive, label-free optical biopsies of biomaterial in ice can be obtained with sub-20 mW mean powers. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. [Present-day advantages of computerized tomography in the diagnosis of chronic inflammatory changes in paranasal sinuses in flying personnel].

    Science.gov (United States)

    Vasil'ev, A Iu; Bessonov, O V; Shevchenko, A G; Grebennikov, A N

    1995-01-01

    The paper demonstrates the diagnostic effectiveness of computer tomography for discovering chronic productive sinus in flying personnel. On the evidence mounted from 190 patients with paranasal sinus, the computer tomography semiotics of various chronic inflammatory processes in sinus has been developed and the comparative analysis of computer tomography and classic X-ray and ultrasonic scanning of sinus has been fulfilled. The computer tomography appears to have high diagnostic potentials for revealing pathology in paranasal sinus in flying personnel. It was confirmed that the technique enables to examine normal anatomy of paranasal sinus, support or invalidate previous diagnosis, and to ascertain the spread and the character of process, visualize alterations in soft and bone tissues and plan surgery.

  8. Determination of the initial energy in computerized tomography with proton beams; Determinacao da energia inicial em tomografia computadorizada com feixe de protons

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Rodrigo Luis da

    2007-07-01

    In earliest works devoted to proton computed tomography it was shown that the advantage of pCT image reconstruction appears when the energy is close to the Bragg peak region, since the proton passes the object. This effect provided by the Bragg peak makes the computerized tomography with protons possible. However, when decreasing the initial proton energy, with the increase of the irradiation dose, there are two effects that work simultaneously in opposite ways. First, the energy loss of a proton in an object becomes bigger at small initial energy. At the same time decreasing of the proton energy results in the increase of the energy straggling, requiring a larger number of protons. In this work the radiation dose dependence on the proton initial energy was studied using analytical formulas and computer simulations. The investigation determined that the radiation dose practically does not depend on the initial energy, except in the energy region very close to the minimum energy necessary to pass the object. (author)

  9. Prognostic value of technetium-99m-labeled single-photon emission computerized tomography in the follow-up of patients after their first myocardial revascularization surgery

    Directory of Open Access Journals (Sweden)

    Márcia Maria Sales dos Santos

    2003-01-01

    Full Text Available OBJECTIVE: To assess the prognostic value of Technetium-99m-labeled single-photon emission computerized tomography (SPECT in the follow-up of patients who had undergone their first myocardial revascularization. METHODS: We carried out a retrospective study of 280 revascularized patients undergoing myocardial scintigraphy under stress (exercise or pharmacological stress with dipyridamole and at rest according to a 2-day protocol. A set of clinical, stress electrocardiographic and scintigraphic variables was assessed. Cardiac events were classified as "major" (death, infarction, unstable angina and "any" (major event or coronary angioplasty or new myocardial revascularization surgery. RESULTS: Thirty-six major events occurred as follows: 3 deaths, 11 infarctions, and 22 unstable anginas. In regard to any event, 22 angioplasties and 7 new surgeries occurred in addition to major events, resulting a total of 65 events. The sensitivity of scintigraphy in prognosticating a major event or any event was, respectively, 55% and 58%, showing a negative predictive value of 90% and 83%, respectively. Diabetes mellitus, inconclusive stress electrocardiography, and a scintigraphic visualization of left ventricular enlargement were significant variables for the occurrence of a major event. On multivariate analysis, abnormal myocardial scintigraphy was a predictor of any event. CONCLUSION: Myocardial perfusion tomography with Technetium-99m may be used to identify high-risk patients after their first myocardial revascularization surgery.

  10. Enhanced High Resolution RBS System

    Science.gov (United States)

    Pollock, Thomas J.; Hass, James A.; Klody, George M.

    2011-06-01

    Improvements in full spectrum resolution with the second NEC high resolution RBS system are summarized. Results for 50 Å TiN/HfO films on Si yielding energy resolution on the order of 1 keV are also presented. Detector enhancements include improved pulse processing electronics, upgraded shielding for the MCP/RAE detector, and reduced noise generated from pumping. Energy resolution measurements on spectra front edge coupled with calculations using 0.4mStr solid angle show that beam energy spread at 400 KeV from the Pelletron® accelerator is less than 100 eV. To improve user throughput, magnet control has been added to the automatic data collection. Depth profiles derived from experimental data are discussed. For the thin films profiled, depth resolutions were on the Angstrom level with the non-linear energy/channel conversions ranging from 100 to 200 eV.

  11. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  12. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  13. Cone-beam computerized tomography imaging and analysis of the upper airway: a systematic review of the literature.

    NARCIS (Netherlands)

    Guijarro-Martinez, R.; Swennen, G.R.J.

    2011-01-01

    A systematic review of the literature concerning upper airway imaging and analysis using cone-beam computed tomography (CBCT) was performed. A PubMed search (National Library of Medicine, NCBI; revised 9th January 2011) yielded 382 papers published between 1968 and 2010. The 382 full papers were

  14. High resolution multimodal clinical ophthalmic imaging system.

    Science.gov (United States)

    Mujat, Mircea; Ferguson, R Daniel; Patel, Ankit H; Iftimia, Nicusor; Lue, Niyom; Hammer, Daniel X

    2010-05-24

    We developed a multimodal adaptive optics (AO) retinal imager which is the first to combine high performance AO-corrected scanning laser ophthalmoscopy (SLO) and swept source Fourier domain optical coherence tomography (SSOCT) imaging modes in a single compact clinical prototype platform. Such systems are becoming ever more essential to vision research and are expected to prove their clinical value for diagnosis of retinal diseases, including glaucoma, diabetic retinopathy (DR), age-related macular degeneration (AMD), and retinitis pigmentosa. The SSOCT channel operates at a wavelength of 1 microm for increased penetration and visualization of the choriocapillaris and choroid, sites of major disease activity for DR and wet AMD. This AO system is designed for use in clinical populations; a dual deformable mirror (DM) configuration allows simultaneous low- and high-order aberration correction over a large range of refractions and ocular media quality. The system also includes a wide field (33 deg.) line scanning ophthalmoscope (LSO) for initial screening, target identification, and global orientation, an integrated retinal tracker (RT) to stabilize the SLO, OCT, and LSO imaging fields in the presence of lateral eye motion, and a high-resolution LCD-based fixation target for presentation of visual cues. The system was tested in human subjects without retinal disease for performance optimization and validation. We were able to resolve and quantify cone photoreceptors across the macula to within approximately 0.5 deg (approximately 100-150 microm) of the fovea, image and delineate ten retinal layers, and penetrate to resolve features deep into the choroid. The prototype presented here is the first of a new class of powerful flexible imaging platforms that will provide clinicians and researchers with high-resolution, high performance adaptive optics imaging to help guide therapies, develop new drugs, and improve patient outcomes.

  15. High-resolution nuclear magnetic resonance imaging and single photon emission computerized tomography--cerebral blood flow in a case of pure sensory stroke and mild dementia owing to subcortical arteriosclerotic encephalopathy (Binswanger's disease)

    DEFF Research Database (Denmark)

    De Chiara, S; Lassen, N A; Andersen, A R

    1987-01-01

    . In addition, NMRI unexpectedly showed diffuse periventricular demyelinization as well as three other lacunar infarcts, i.e., findings characteristic of subcortical arteriosclerotic encephalopathy (SAE). This prompted psychometric testing, which revealed signs of mild (subclinical) dementia, in particular...

  16. Analysis of donor sites for mandibular bone grafts by computerized cone beam tomography to evaluate bone remodeling

    Directory of Open Access Journals (Sweden)

    Thomaz Wassall

    2009-01-01

    Full Text Available Objective: To analyze the graft donor site (posterior region of the mandible by means of cone-beam volumetric tomographies to assess boneremodeling, verifying the degree of morbidity with regard to this parameter. Methods: The sample was composed of twenty individuals, irrespective of age, gender and ASA I and ASA II surgical risk classification. Three volume computed tomographies were performed: one before surgery, another seven days after surgery and the last 180 days after surgery. Image acquisition by volumetric cone-beam tomography and the computer program Dental Slice were used to make the measurements. Results: Statistics showed that there was significant bone remodeling. Although there are several concerns about the graft donor sites, no data were obtained in the literature, about the assessment of bone remodeling of the donor site. Conclusion: Mean remodeling in the posterior region of the mandible, assessed 180 days after graft removal is 81.3%, on an average, andmorbidity in the posterior donor site of the mandible has been small, when compared with the other donor sites, both intra-oral and extra-oral, according to the data in the specific literature.

  17. Impact of renal anatomy on shock wave lithotripsy outcomes for lower pole kidney stones: results of a prospective multifactorial analysis controlled by computerized tomography.

    Science.gov (United States)

    Torricelli, Fabio C M; Marchini, Giovanni S; Yamauchi, Fernando I; Danilovic, Alexandre; Vicentini, Fabio C; Srougi, Miguel; Monga, Manoj; Mazzucchi, Eduardo

    2015-06-01

    We evaluated which variables impact fragmentation and clearance of lower pole calculi after shock wave lithotripsy. We prospectively evaluated patients undergoing shock wave lithotripsy for a solitary 5 to 20 mm lower pole kidney stone between June 2012 and August 2014. Patient body mass index and abdominal waist circumference were recorded. One radiologist blinded to shock wave lithotripsy outcomes measured stone size, area and density, stone-to-skin distance, infundibular length, width and height, and infundibulopelvic angle based on baseline noncontrast computerized tomography. Fragmentation, success (defined as residual fragments less than 4 mm in asymptomatic patients) and the stone-free rate were evaluated by noncontrast computerized tomography 12 weeks postoperatively. Univariate and multivariate analysis was performed. A total of 100 patients were enrolled in the study. Mean stone size was 9.1 mm. Overall fragmentation, success and stone-free rates were 76%, 54% and 37%, respectively. On logistic regression body mass index (OR 1.27, 95% CI 1.11-1.49, p = 0.004) and stone density (OR 1.0026, 95% CI 1.0008-1.0046, p = 0.005) significantly impacted fragmentation. Stone size (OR 1.24, 95% CI 1.07-1.48, p = 0.039) and stone density (OR 1.0021, 95% CI 1.0007-1.0037, p = 0.012) impacted the success rate while stone size (OR 1.24, 95% CI 1.04-1.50, p = 0.029), stone density (OR 1.0015, 95% CI 1.0001-1.0032, p = 0.046) and infundibular length (OR 1.1035, 95% CI 1.015-1.217, p = 0.015) impacted the stone-free rate. The best outcomes were found in patients with a body mass index of 30 kg/m(2) or less, stones 10 mm or less and 900 HU or less, and an infundibular length of 25 mm or less. The coexistence of significant unfavorable variables led to a stone-free rate of less than 20%. Obese patients with higher than 10 mm density stones (greater than 900 HU) in the lower pole of the kidney with an infundibular length of greater than 25 mm should be discouraged from

  18. Fabricating High-Resolution X-Ray Collimators

    Science.gov (United States)

    Appleby, Michael; Atkinson, James E.; Fraser, Iain; Klinger, Jill

    2008-01-01

    A process and method for fabricating multi-grid, high-resolution rotating modulation collimators for arcsecond and sub-arcsecond x-ray and gamma-ray imaging involves photochemical machining and precision stack lamination. The special fixturing and etching techniques that have been developed are used for the fabrication of multiple high-resolution grids on a single array substrate. This technology has application in solar and astrophysics and in a number of medical imaging applications including mammography, computed tomography (CT), single photon emission computed tomography (SPECT), and gamma cameras used in nuclear medicine. This collimator improvement can also be used in non-destructive testing, hydrodynamic weapons testing, and microbeam radiation therapy.

  19. Evaluation of Advanced Bionics high resolution mode.

    Science.gov (United States)

    Buechner, Andreas; Frohne-Buechner, Carolin; Gaertner, Lutz; Lesinski-Schiedat, Anke; Battmer, Rolf-Dieter; Lenarz, Thomas

    2006-07-01

    The objective of this paper is to evaluate the advantages of the Advanced Bionic high resolution mode for speech perception, through a retrospective analysis. Forty-five adult subjects were selected who had a minimum experience of three months' standard mode (mean of 10 months) before switching to high resolution mode. Speech perception was tested in standard mode immediately before fitting with high resolution mode, and again after a maximum of six months high resolution mode usage (mean of two months). A significant improvement was found, between 11 and 17%, depending on the test material. The standard mode preference does not give any indication about the improvement when switching to high resolution. Users who are converted within any study achieve a higher performance improvement than those converted in the clinical routine. This analysis proves the significant benefits of high resolution mode for users, and also indicates the need for guidelines for individual optimization of parameter settings in a high resolution mode program.

  20. Tuberculous otitis media: findings on high-resolution CT

    Energy Technology Data Exchange (ETDEWEB)

    Lungenschmid, D. [Dept. of Radiodiagnostics, University Hospital Innsbruck (Austria)]|[Dept. of Magnetic Resonance and Spectroscopy, University Hospital of Innsbruck (Austria); Buchberger, W. [Dept. of Radiodiagnostics, University Hospital Innsbruck (Austria)]|[Dept. of Magnetic Resonance and Spectroscopy, University Hospital of Innsbruck (Austria); Schoen, G. [Dept. of Radiodiagnostics, University Hospital Innsbruck (Austria); Schoepf, R. [Radiologic Inst., Landeck (Austria); Mihatsch, T. [Dept. of Oto-Rhino-Laryngology, University Hospital of Innsbruck (Austria); Birbamer, G. [Dept. of Magnetic Resonance and Spectroscopy, University Hospital of Innsbruck (Austria); Wicke, K. [Inst. of Computed Tomography, University Hospital of Innsbruck (Austria)

    1993-12-01

    We describe two cases of tuberculous otitis media studied with high-resolution computed tomography (CT). Findings included extensive soft tissue densities with fluid levels in the tympanic cavity, the antrum, the mastoid and petrous air cells. Multifocal bony erosions and reactive bone sclerosis were seen as well. CT proved valuable for planning therapy by accurately displaying the involvement of the various structures of the middle and inner ear. However, the specific nature of the disease could only be presumed. (orig.)

  1. Rupture of Ovarian Mature Cystic Teratoma: Computerized Tomography Findings; Rotura de teratoma quistico madure de ovario: hallazgos por tomografia computerizada

    Energy Technology Data Exchange (ETDEWEB)

    Sebastia, C.; Sarrias, M.; Sanchez-Aliaga, E.; Quiroga, S.; Boye, R.; Alvarez-Castells, A. [Hospital General Universitari Vall d' Hebron. Barcelona (Spain)

    2004-07-01

    We present computed tomography findings of three cases of intraperitoneal rupture of ovarian mature cystic teratoma. Acute-phase radiological findings include presence of intraabdominal liquid, infiltration of mesenteric fat and calcified pelvic mass which also showed interior fatty content. Chronic-phase findings include infiltration of peritoneal fat, as well as increase in the size of adjacent ganglion due to chronic inflammatory response to histologically verified foreign bodies. Differential diagnoses between chronic and acute intraperitoneal ruptures of mature teratoma have been reviewed. (Author)

  2. Detection of vertical root fractures by cone-beam computerized tomography in endodontically treated teeth with fiber-resin and titanium posts: an in vitro study.

    Science.gov (United States)

    Ferreira, Rívea Inês; Bahrami, Golnosh; Isidor, Flemming; Wenzel, Ann; Haiter-Neto, Francisco; Groppo, Francisco Carlos

    2013-01-01

    The aim of this study was to assess the performance of 2 cone-beam computerized tomography (CBCT) systems for detecting vertical fractures in root-filled teeth with fiber-resin or titanium posts. CBCT images acquired with the use of Scanora 3D and i-CAT of roots with fiber-resin (n = 30) or titanium (n = 29) posts, before and after the induction of fractures, were assessed by 6 radiologists using Ondemand 3D software. Interobserver agreement was analyzed using kappa statistics. Sensitivity, specificity, accuracy, and positive and negative predictive values were compared with analysis of variance/Student-Newman-Keuls test. Interobserver agreement for fiber-resin posts ranged from 0.5 to 0.7 (Scanora 3D) and 0.35-0.76 (i-CAT). For titanium posts, ranged from 0.42 to 0.80 (Scanora 3D) and 0.31-0.73 (i-CAT). Higher sensitivity (0.85; P negative predictive values (0.88; P posts than with other combinations. The diagnostic performance for detecting vertical fractures was higher for roots with fiber-resin than with titanium posts. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. A study of root canal morphology of human primary incisors and molars using cone beam computerized tomography: an in vitro study.

    Science.gov (United States)

    Gaurav, Vivek; Srivastava, Nikhil; Rana, Vivek; Adlakha, Vivek Kumar

    2013-01-01

    Variations in morphology of root canals in primary teeth usually leads to complications during and after endodontic therapy. To improve the success in endodontics, a thorough knowledge of the root canal morphology is essential. The aim of this study was to assess the variation in number and morphology of the root canals of primary incisors and molars and to study the applicability of cone beam computerized tomography (CBCT) in assessing the same. A total of 60 primary molars and incisors with full root length were collected and various parameters such as the number of roots, number of canals, diameter of root canal at cementoenamel junction and middle-third, length and angulations of roots of primary molars and incisors were studied using CBCT. The observations were put to descriptive statistics to find out the frequency, mean, standard deviation and range for all four subgroups. Further, unpaired t-test was used to compare these parameters between subgroups and analysis of variance test was implemented to evaluate the parameters within the subgroups. The CBCT showed the presence of bifurcation of root canal at middle third in 13% of mandibular incisors while 20% of mandibular molars had two canals in distal root. The diameter of distobuccal root canal of maxillary molars and mesiolingual canal of mandibular molars was found to be minimum. CBCT is a relatively new and effective technology, which provides an auxiliary imaging modality to supplement conventional radiography for assessing the variation in root canal morphology of primary teeth.

  4. The role of computerized tomography in the evaluation of gastrointestinal bleeding following negative or failed endoscopy: a review of current status.

    Science.gov (United States)

    Stunell, H; Buckley, O; Lyburn, I D; McGann, G; Farrell, M; Torreggiani, W C

    2008-01-01

    Gastrointestinal bleeding remains an important cause for emergency hospital admission with a significant related morbidity and mortality. Bleeding may relate to the upper or lower gastrointestinal tracts and clinical history and examination may guide investigations to the more likely source of bleeding. The now widespread availability of endoscopic equipment has made a huge impact on the rapid identification of the bleeding source. However, there remains a large group of patients with negative or failed endoscopy, in whom additional techniques are required to identify the source of bleeding. In the past, catheter angiography and radionuclide red cell labeling techniques were the preferred 'next step' modalities used to aid in identifying a bleeding source within the gastrointestinal tract. However, these techniques are time-consuming and of limited sensitivity and specificity. In addition, catheter angiography is a relatively invasive procedure. In recent years, computerized tomography (CT) has undergone major technological advances in its speed, resolution, multiplanar techniques and angiographic abilities. It has allowed excellent visualization of the both the small and large bowel allowing precise anatomical visualization of many causes of gastrointestinal tract (GIT) bleeding. In addition, recent advances in multiphasic imaging now allow direct visualization of bleeding into the bowel. In many centers CT has therefore become the 'next step' technique in identifying a bleeding source within the GIT following negative or failed endoscopy in the acute setting. In this review article, we review the current literature and discuss the current status of CT as a modality in investigating the patient with GIT bleeding.

  5. A Micro-Scale Investigation on the Behaviors of Asphalt Mixtures under Freeze-Thaw Cycles Using Entropy Theory and a Computerized Tomography Scanning Technique

    Directory of Open Access Journals (Sweden)

    Huining Xu

    2018-01-01

    Full Text Available The thermodynamic behavior of asphalt mixtures is critical to the engineers since it directly relates to the damage in asphalt mixtures. However, most of the current research of the freeze-thaw damage of asphalt mixtures is focused on the bulk body from the macroscale and lacks a fundamental understanding of the thermodynamic behaviors of asphalt mixtures from the microscale perspective. In this paper, to identify the important thermodynamic behaviors of asphalt mixtures under freeze-thaw loading cycle, the information entropy theory, an X-ray computerized tomography (CT scanner and digital image processing technology are employed. The voids, the average size of the voids, the connected porosity, and the void number are extracted according to the scanned images. Based on the experiments and the CT scanned images, the information entropy evolution of the asphalt mixtures under different freeze-thaw cycles is calculated and the relationship between the change of information entropy and the pore structure characteristics is established. Then, the influences of different freezing and thawing conditions on the thermodynamic behaviors of asphalt mixtures are compared. The combination of information entropy theory and CT scanning technique proposed in this paper provides an innovative approach to investigate the thermodynamics behaviors of asphalt mixtures and a new way to analyze the freeze-thaw damage in asphalt mixtures.

  6. [Comparative study of X-ray digital tomosynthesis imaging based on intravenous urography and unenhanced multidetector-row computerized tomography in urinary calculi].

    Science.gov (United States)

    Tuerdi, Batuer; Wang, Hui; Huo, Zhong; Abula, Gulipiyan; Mahemuti, Biekemulati; Abulizi, Maihemuti

    2014-04-22

    To evaluate the clinical application value of X-ray digital DTSynthesis (DTS) based on IVU (Intravenous Urography)in urinary calculi contrasted with unenhanced multidetector-row computerized tomography. 75 patients suspected of urinary calculi underwent IVU, DTS based on IVU and UMDCT. The diagnostic sensitivity, specificity, accuracy, positive predictive value and negative predictive of the three imaging ways were acquired according to operations, respectively. Chi-square test was used to evaluate the difference among the three ways. In 75 cases, 60 cases were proved to be urinary calculi. The diagnostic sensitivity, specificity, accuracy, positive predictive value and negative predictive of IVU, DTS based on IVU,UMDCT is 70.0%, 73.3%, 70.7%, 91.3%, 37.9%; 91.7%, 86.7%, 90.7%, 96.5%, 72.2%; 96.7%, 86.7%, 94.7%, 96.7%, 86.7%, respectively.No significant differences between DTS based on IVU and UMDCT were found in sensitivity, specificity, accuracy, positive predictive value and negative predictive. Both cases are better than IVU in diagnostic ability. There is no significant difference in diagnostic ability of urinary calculi between DTS and UMDCT. DTS can be used as a routine imaging technique in diagnosis and follow up of urinary calculi.

  7. Horizontal Bone Augmentation Using Autogenous Block Grafts and Particulate Xenograft in the Severe Atrophic Maxillary Anterior Ridges: A Cone-Beam Computerized Tomography Case Series.

    Science.gov (United States)

    Monje, Alberto; Monje, Florencio; Hernández-Alfaro, Federico; Gonzalez-García, Raúl; Suárez-López del Amo, Fernando; Galindo-Moreno, Pablo; Montanero-Fernández, Jesús; Wang, Hom-Lay

    2015-07-01

    The aim of the present study was to use cone-beam computerized tomography (CBCT) to assess horizontal bone augmentation using block grafts, harvested from either the iliac crest (IC) or mandibular ramus (MR) combined with particulate xenograft and a collagen membrane for in the severe maxillary anterior ridge defects (cases Class III-IV according to Cadwood and Howell's classification). Fourteen healthy partially edentulous patients requiring extensive horizontal bone reconstruction in the anterior maxilla were selected for the study. Nineteen onlay block grafts (from IC or MR) were placed. The amount of horizontal bone gain was recorded by CBCT at 3 levels (5, 7, and 11 mm from the residual ridge) and at the time of bone grafting as well as the time of implant placement (≈5 months). Both block donor sites provided enough ridge width for proper implant placement. Nonetheless, IC had significantly greater ridge width gain than MR (Student t test) (4.93 mm vs 3.23 mm). This was further confirmed by nonparametric Mann-Whitney test (P = .007). Moreover, mean pristine ridge and grafted ridge values showed a direct association (Spearman coefficient of correlation = .336). A combination of block graft, obtained from the IC or MR, combined with particulate xenograft then covered with an absorbable collagen membrane is a predictable technique for augmenting anterior maxillary horizontal ridge deficiency.

  8. Evaluation of the soil-seed environment through computerized tomography; Avaliacao do ambiente solo-semente por meio da tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Modolo, Alcir Jose [Universidade Tecnologica Federal do Parana (UTFPR), Pato Branco, PR (Brazil)). E-mail: alcir@ufpr.edu.br; Fernandes, Haroldo Carlos [Universidade Federal de Vicosa (UFV), MG (Brazil). Dept. de Engenharia Agricola]. E-mail: haroldo@ufv.br; Naime, Joao de Mendonca [Embrapa Instrumentacao Agropecuaria, Sao Carlos, SP (Brazil)]. E-mail: naime@cnpdia.embrapa.br; Schaefer, Carlos Ernesto G.R. [Universidade Federal de Vicosa (UFV), MG (Brazil). Dept. de Solos]. E-mail: carlos.schaefer@ufv.br; Santos, Nerilson Terra [Universidade Federal de Vicosa (UFV), MG (Brazil). Dept. de Informatica]. E-mail: nsantos@ufv.br; Silveira, Joao Cleber Modernel da [Universidade Federal de Vicosa (UFV), MG (Brazil). Mecanizacao Agricola]. E-mail: jcmodernel@uol.com.br

    2008-03-15

    The physical conditioning of the soil around seeds is of great importance for an adequate initial development of a crop, ensuring a healthy plant population. A suitable soil-seed contact is a prerequisite for a fast crop germination and good establishment. In this study, computerized tomography of millimeter resolution was used to determine the soil-seed environment in a no tillage system, immediately after soybean planting. A split plot design was used, in which the plots consisted of three contents of soil water, corresponding to 0.27; 0,31 and 0.36 kg kg{sup -1}, respectively, and the split plots of four load levels applied by the compaction wheel, corresponding to 0, 50, 90 and 140 N, respectively. It was used a random block design, with four replications. The medium soil density in the seed area and the medium density profile in the sowing furrow were evaluated. According to the results, it may be concluded that: the loads applied by the compaction wheel increased soil density at the vertical planting level beneath planting depth as compared with values obtained before planting, and; the combination of wheel loads and soil water contents did not influence the mean soil density in the seed area. (author)

  9. Experimental study of mechanisms of sand production using X-ray computerized tomography; Estudo experimental dos mecanismos da producao de areia empregando tomografia computadorizada de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Janaina B.; Vargas Junior, Euripedes [Pontificia Univ. Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. de Engenharia Civil; Barroso, Emilio V. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Geologia; Campos, Elisabete; Goncalves, Clemente; Tavares, Andre [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES)

    2004-07-01

    During productive phase of the well, many times there is simultaneous production of the solid particles detached from matrix of the reservoir rock. This phenomenon receives the name of the sand production. In this case stress and flow conditions around of the well are fundamental factors for deflagration of the process. Stress concentration in the wall of the well lead to the loss of cohesion between grains arising, consequently, a granular material region susceptible for dragging by seepage forces derived from fluid flow. The objective of this work was to perform sand production tests in Rio Bonito and synthetic sandstone samples using real-time X-Ray Computerized Tomography. The tests investigated the initial and the evolution of failure at the cavity wall of samples. These are initial stages of the sand production process. The analysis of the CT-scans obtained during tests allowed the visualization of breakouts and collapses of the wells. From studies more details were possible estimate the sand production and produce 3-D images of the propagation of the failure. (author)

  10. The usefulness of ultrasound colour-Doppler twinkling artefact for detecting urolithiasis compared with low dose nonenhanced computerized tomography

    DEFF Research Database (Denmark)

    Winkel, Rikke Rass; Kalhauge, Anna; Fredfeldt, Knud-Erik

    2012-01-01

    This prospective study evaluates the usefulness of the twinkling artefact (TA) seen on colour-Doppler ultrasound (US) in diagnosing urolithiasis. US and standard computed tomography (CT) were performed blinded on 105 patients. B-mode US and colour-Doppler used separately and in combination showed...... 55% sensitivity and 99% specificity (positive predictive value [PPV] 67% and negative predictive value [NPV] 98%). Of CT verified stones, 61% were ≤3 mm. TAs were present in 74% of the B-mode stones (43% of all CT verified stones). Patients with CT verified stone disease had significantly more TAs......, US and US with colour-Doppler TA can be useful as complementary techniques for detecting stones....

  11. [Validity of modified radiological views to detect screw protrusion at the distal radius. A comparative study with computerized tomography].

    Science.gov (United States)

    Mora-Pascual, F E; Aguilella-Fernández, L

    2013-01-01

    Volar fixed-angle plates (VFAP) are currently widely used for the treatment of extra-articular distal radius fractures. Using these plates has a high risk of articular and dorsal screw protrusion due to their special configuration. The aim of this study is to assess the validity of the standard X-rays, performed with the help of wedged supports, in order to detect articular and dorsal screw protrusion. A comparison with computed tomography (CT) scan imaging has been made. The outcome of 26 patients with distal radius articular fracture, treated with a VFAP, is reported. Good correlation between modified X-rays and CT scan was observed. A sensitivity of 100% for articular protrusion and 66% for dorsal have been obtained. When detecting screw protrusion at the distal radius, the use of wedged supports to perform special X-rays intraoperatively is an effective tool. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.

  12. Clinical significance of mesenteric panniculitis-like abnormalities on abdominal computerized tomography in patients with malignant neoplasms.

    Science.gov (United States)

    Ehrenpreis, Eli D; Roginsky, Grigory; Gore, Richard M

    2016-12-28

    To clarify the association of malignancy with mesenteric panniculitis-like changes on computed tomography (CT). All abdominal CT scans performed at NorthShore University HealthSystem showing mesenteric panniculitis from January 2005 to August 2010 were identified in the Radnet (RadNet Corporation, Los Angeles, CA) database. Patients with a new or known diagnosis of a malignancy were included for this analysis. Longitudinal clinical histories were obtained from electronic medical records. In total, 147794 abdominal CT scans were performed during the study period. Three hundred and fifty-nine patients had mesenteric panniculitis (MP)-like abnormalities on their abdominal CT. Of these patients, 81 patients (22.6%) had a known history of cancer at the time of their CT scan. Nineteen (5.3%) had a new diagnosis of cancer in concurrence with their CT, but the majority of these (14/19, 74%) were undergoing CT as part of a malignancy evaluation. Lymphomas were the most common cancers associated with MP-like findings on CT (36 cases, 36%), with follicular lymphoma being the most frequent subtype (17/36). A variety of solid tumors, most commonly prostate (7) and renal cell cancers (6) also were seen. CT follow up was obtained in 56 patients. Findings in the mesentery were unchanged in 45 (80%), worsened in 6 (11%), and improved in 5 patients (9%). Positron emission tomography (PET) scans performed in 44 patients only showed a positive uptake in the mesenteric mass in 2 patients (5%). A new diagnosis of cancer is uncommon in patients with CT findings suggestive of MP. MP-like mesenteric abnormalities on CT generally remain stable in patients with associated malignancies. PET scanning is not recommended in the evaluation of patients with mesenteric panniculitis-like findings on CT.

  13. Section on High Resolution Optical Imaging (HROI)

    Data.gov (United States)

    Federal Laboratory Consortium — The Section on High Resolution Optical Imaging (HROI) develops novel technologies for studying biological processes at unprecedented speed and resolution. Research...

  14. The evaluation of the angles of Eustachian tubes in the patients with chronic otitis media on the temporal computerized tomography.

    Science.gov (United States)

    Aksoy, S; Sayin, I; Yazici, Z M; Kayhan, F T; Karahasanoglu, A; Hocaoglu, E; Inci, E

    2016-01-01

    Chronic otitis media (COM), affecting all over the world and in a wide range of age groups in Turkey, is an important cause of ear discharge and hearing loss. The main clinical manifestations are tympanic membrane perforation, ear, nose and throat problems. On the tympanic membrane perforation becomes persistent and cholesteatoma development, there are a lot of opinions today. Especially in the pathology associated with otitis media with effusion eustachian tube, it is known that COM and cholesteatoma develop. In our study, we interpreted 210 patients' temporal computed tomography (CT). Seventy of these 210 patients had otitis media with cholesteatoma, 70 patients had only otitis media without cholesteatoma, and 70 patients had no otitis media. The eustachian tubes were evaluated using temporal CT multiplanar reconstruction method. Angles with the horizontal plane of the eustachian tube and Reid and tubotympanic angles were measured. The angles between eustachian tube and horizontally oriented Reid plane of the patients with cholesteatoma were found to be significantly lower than the patients with otitis media without cholesteatoma and the patients with no history of otitis media. For the tubotympanic angle, no statistically significant differences were observed between the groups. These results suggest that the decrease in the angle with the horizontal plane of Reid in the eustachian tube in adults may play a significant role in the etiology of cholesteatoma.

  15. Analysis of the of bones through 3D computerized tomography; Analise de estrutura ossea atraves de microtomografia computadorizada 3D

    Energy Technology Data Exchange (ETDEWEB)

    Lima, I.; Lopes, R.T. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentacao Nuclear; Oliveira, L.F. [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Fisica. Dept. de Fisica Aplicada e Termodinamica; Alves, J.M. [Universidade de Sao Paulo (USP), Sao Carlos, SP (Brazil). Escola de Engenharia

    2009-03-15

    This work shows the analysis of the internal structure of the bones samples through 3D micro tomography technique (3D-{mu}TC). The comprehension of the bone structure is particularly important when related to osteoporosis diagnosis because this implies in a deterioration of the trabecular bone architecture, which increases the fragility and the possibility to have bone fractures. Two bone samples (human calcaneous and Wistar rat femur) were used, and the method was a radiographic system in real time with an X Ray microfocus tube. The quantifications parameters are based on stereological principles and they are five: a bone volume fraction, trabecular number, the ratio between surface and bone volume, the trabecular thickness and the trabecular separation. The quantifications were done with a program developed especially for this purpose in Nuclear Instrumentation Laboratory - COPPE/UFRJ. This program uses as input the 3D reconstructions images and generates a table with the quantifications. The results of the human calcaneous quantifications are presented in tables 1 and 2, and the 3D reconstructions are illustrated in Figure 5. The Figure 6 illustrate the 2D reconstructed image and the Figure 7 the 3D visualization respectively of the Wistar femur sample. The obtained results show that the 3D-{mu}TC is a powerful technique that can be used to analyze bone microstructures. (author)

  16. High resolution multiplexed functional imaging in live embryos (Conference Presentation)

    Science.gov (United States)

    Xu, Dongli; Zhou, Weibin; Peng, Leilei

    2017-02-01

    Fourier multiplexed fluorescence lifetime imaging (FmFLIM) scanning laser optical tomography (FmFLIM-SLOT) combines FmFLIM and Scanning laser optical tomography (SLOT) to perform multiplexed 3D FLIM imaging of live embryos. The system had demonstrate multiplexed functional imaging of zebrafish embryos genetically express Foster Resonant Energy Transfer (FRET) sensors. However, previous system has a 20 micron resolution because the focused Gaussian beam diverges quickly from the focused plane, makes it difficult to achieve high resolution imaging over a long projection depth. Here, we present a high-resolution FmFLIM-SLOT system with achromatic Bessel beam, which achieves 3 micron resolution in 3D deep tissue imaging. In Bessel-FmFLIM-SLOT, multiple laser excitation lines are firstly intensity modulated by a Michelson interferometer with a spinning polygon mirror optical delay line, which enables Fourier multiplexed multi-channel lifetime measurements. Then, a spatial light modulator and a prism are used to transform the modulated Gaussian laser beam to an achromatic Bessel beam. The achromatic Bessel beam scans across the whole specimen with equal angular intervals as sample rotated. After tomography reconstruction and the frequency domain lifetime analysis method, both the 3D intensity and lifetime image of multiple excitation-emission can be obtained. Using Bessel-FmFLIM-SLOT system, we performed cellular-resolution FLIM tomography imaging of live zebrafish embryo. Genetically expressed FRET sensors in these embryo will allow non-invasive observation of multiple biochemical processes in vivo.

  17. A study of root canal morphology of human primary incisors and molars using cone beam computerized tomography: An in vitro study

    Directory of Open Access Journals (Sweden)

    Vivek Gaurav

    2013-01-01

    Full Text Available Background: Variations in morphology of root canals in primary teeth usually leads to complications during and after endodontic therapy. To improve the success in endodontics, a thorough knowledge of the root canal morphology is essential. Aim: The aim of this study was to assess the variation in number and morphology of the root canals of primary incisors and molars and to study the applicability of cone beam computerized tomography (CBCT in assessing the same. Settings and Design: A total of 60 primary molars and incisors with full root length were collected and various parameters such as the number of roots, number of canals, diameter of root canal at cementoenamel junction and middle-third, length and angulations of roots of primary molars and incisors were studied using CBCT. Statistical analysis used: The observations were put to descriptive statistics to find out the frequency, mean, standard deviation and range for all four subgroups. Further, unpaired t-test was used to compare these parameters between subgroups and analysis of variance test was implemented to evaluate the parameters within the subgroups. Results and Conclusion: The CBCT showed the presence of bifurcation of root canal at middle third in 13% of mandibular incisors while 20% of mandibular molars had two canals in distal root. The diameter of distobuccal root canal of maxillary molars and mesiolingual canal of mandibular molars was found to be minimum. CBCT is a relatively new and effective technology, which provides an auxiliary imaging modality to supplement conventional radiography for assessing the variation in root canal morphology of primary teeth.

  18. The role of computerized tomography in the evaluation of gastrointestinal bleeding following negative or failed endoscopy: A review of current status

    Directory of Open Access Journals (Sweden)

    Stunell H

    2008-01-01

    Full Text Available Gastrointestinal bleeding remains an important cause for emergency hospital admission with a significant related morbidity and mortality. Bleeding may relate to the upper or lower gastrointestinal tracts and clinical history and examination may guide investigations to the more likely source of bleeding. The now widespread availability of endoscopic equipment has made a huge impact on the rapid identification of the bleeding source. However, there remains a large group of patients with negative or failed endoscopy, in whom additional techniques are required to identify the source of bleeding. In the past, catheter angiography and radionuclide red cell labeling techniques were the preferred ′next step′ modalities used to aid in identifying a bleeding source within the gastrointestinal tract. However, these techniques are time-consuming and of limited sensitivity and specificity. In addition, catheter angiography is a relatively invasive procedure. In recent years, computerized tomography (CT has undergone major technological advances in its speed, resolution, multiplanar techniques and angiographic abilities. It has allowed excellent visualization of the both the small and large bowel allowing precise anatomical visualization of many causes of gastrointestinal tract (GIT bleeding. In addition, recent advances in multiphasic imaging now allow direct visualization of bleeding into the bowel. In many centers CT has therefore become the ′next step′ technique in identifying a bleeding source within the GIT following negative or failed endoscopy in the acute setting. In this review article, we review the current literature and discuss the current status of CT as a modality in investigating the patient with GIT bleeding.

  19. Single photon emission computed tomography (SPECT) and SPECT/low-dose computerized tomography did not increase sensitivity or specificity compared to planar bone scintigraphy for detection of bone metastases in advanced breast cancer.

    Science.gov (United States)

    Haraldsen, Ate; Bluhme, Henrik; Røhl, Lisbeth; Pedersen, Erik Morre; Jensen, Anders Bonde; Hansen, Eva Boysen; Nellemann, Hanne; Rasmussen, Finn; Morsing, Anni

    2016-01-01

    To evaluate and compare the diagnostic performance of whole-body planar bone scintigraphy (WBS), single photon emission computed tomography (SPECT), SPECT/low-dose computerized tomography (SPECT/ldCT) and SPECT/contrast enhanced diagnostic CT (SPECT/cdCT) in the staging of patients with advanced breast cancer. Seventy-eight patients with recurrence of biopsy-proven breast cancer and suspicion of disseminated disease were investigated with WBS, SPECT, SPECT/ldCT, SPECT/cdCT and MRI performed on the same day in this prospective study. Images were separately analysed in a blinded fashion by radiologists and nuclear medicine physicians regarding the presence of pathological findings. MRI served as reference standard. According to reference standard, 38 of 73 patients had bone metastases. The sensitivity was 87%, 87%, 79%, and 84% and specificity 63%, 71%, 63% and 83% for WBS, SPECT, SPECT/ldCT and SPECT/cdCT. A significantly increased specificity of SPECT/cdCT compared to WBS and SPECT/ldCT was found, and other parameters did not differ significantly between modalities. Additional two patients had bone metastases solely located outside the MRI scan field and seven patients had soft tissue metastases, but no skeletal changes on MRI. WBS, SPECT and SPECT/ldCT were less sensitive than MRI and equally specific for the detection of bone metastases in patients with advanced breast cancer. Based on our findings, we suggest that initial staging include WBS, MRI of the spine and CT for soft tissue evaluation. Further studies may clarify the potential benefits of whole-body MRI and 18F-NaF PET/CT or 18F-FDG PET/CT. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  20. Is 18F-fluorocholine-positron emission tomography/computerized tomography a new imaging tool for detecting hyperfunctioning parathyroid glands in primary or secondary hyperparathyroidism?

    Science.gov (United States)

    Michaud, Laure; Burgess, Alice; Huchet, Virginie; Lefèvre, Marine; Tassart, Marc; Ohnona, Jessica; Kerrou, Khaldoun; Balogova, Sona; Talbot, Jean-Noël; Périé, Sophie

    2014-12-01

    Preoperative ultrasonography and scintigraphy using (99m)Tc-sestamibi are commonly used to localize abnormal parathyroid glands. In cases of discrepant results between scintigraphy and ultrasonography, it is important to rely on another diagnostic imaging modality. (18)F-fluorodeoxyglucose (FDG) and (11)C-methionine positron emission tomography (PET) have been studied, but are imperfect to detect abnormal parathyroid glands. Recently, first cases of abnormal parathyroid glands taking-up radiolabelled choline were discovered incidentally in men referred to (11)C-choline or (18)F-fluorocholine (FCH)-PET/CT for prostate cancer. We checked if FCH uptake was a general feature of adenomatous or hyperplastic parathyroid glands. FCH-PET/CT was performed in 12 patients with primary (n = 8) or secondary hyperparathyroidism (1 dialyzed, 3 grafted) and with discordant or equivocal results on preoperative ultrasonography (US) and/or (123)I/(99m)Tc-sestamibi dual-phase scintigraphy. The results of the FCH-PET/CT were evaluated, with surgical exploration and histopathologic examination as the standard of truth. On a per-patient level, the detection rate of FCH-PET/CT (at least one FCH focus corresponding to an abnormal parathyroid gland in a given patient) was 11/12 = 92%. FCH-PET/CT detected 18 foci interpreted as parathyroid glands and correctly localized 17 abnormal parathyroid glands (7 adenomas and 10 hyperplasias). On a per-lesion level, FCH-PET/CT results were 17 TP, 2 false negative ie, a lesion-based sensitivity of 89%, and 1 false positive. As the main result of this pilot study, we show that in patients with hyperparathyroidism and with discordant or equivocal results on scintigraphy or on ultrasonography, adenomatous or hyperplastic parathyroid glands can be localized by FCH-PET/CT with good accuracy. Furthermore, FCH-PET/CT can solve discrepant results between preoperative ultrasonography and scintigraphy and has thus a potential as a functional imaging modality in

  1. Computerized tomography with X-rays: an instrument in the analysis physico-chemical between formations and drilling fluids interactions; Tomografia computadorizada com raios-X: uma ferramenta na analise das interacoes fisico-quimicas entre as formacoes rochosas e fluidos de perfuracao

    Energy Technology Data Exchange (ETDEWEB)

    Coelho, Marcus Vinicius Cavalcante

    1998-12-31

    In this study it is demonstrated the applicability of the Computerized Tomography technique with x-rays to evaluate the reactivity degree between various drilling fluids and argillaceous sediments (Shales and Sandstones). The research has been conducted in the Rock-Fluid Interaction Pressure Simulator (RFIPS), where the possible physico-chemical alterations can be observed through successive tomography images, which are obtained during the flow of the fluid through the samples. In addition, it was noticed the formation of mud cake in Berea Sandstones samples in the RFIPS, though the Computerized Tomography with X-rays, when utilizing drilling fluids weighted with the baryte. (author) 35 refs., 38 figs., 5 tabs.

  2. VT Hydrography Dataset - High Resolution NHD

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The Vermont Hydrography Dataset (VHD) is compliant with the local resolution (also known as High Resolution) National Hydrography Dataset (NHD)...

  3. High Resolution Silicon Deformable Mirrors Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this proposal we describe a plan to build a deformable mirror suitable for space-based operation in systems for high-resolution imaging. The prototype DM will be...

  4. High Resolution Silicon Deformable Mirrors Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal describes a plan to build a prototype small stroke, high precision deformable mirror suitable for space-based operation in systems for high-resolution...

  5. Structure of high-resolution NMR spectra

    CERN Document Server

    Corio, PL

    2012-01-01

    Structure of High-Resolution NMR Spectra provides the principles, theories, and mathematical and physical concepts of high-resolution nuclear magnetic resonance spectra.The book presents the elementary theory of magnetic resonance; the quantum mechanical theory of angular momentum; the general theory of steady state spectra; and multiple quantum transitions, double resonance and spin echo experiments.Physicists, chemists, and researchers will find the book a valuable reference text.

  6. Fentanyl Iontophoretic Transdermal System (IONSYS(®)) can be Safely used in the Hospital Environment with X-Rays, Computerized Tomography and Radiofrequency Identification Devices.

    Science.gov (United States)

    Lemke, John; Sardariani, Edmond; Phipps, Joseph Bradley; Patel, Niki; Itri, Loretta M; Caravelli, James; Viscusi, Eugene R

    2016-09-01

    Fentanyl iontophoretic transdermal system (fentanyl ITS, IONSYS(®)) is a patient-controlled analgesia system used for the management of acute postoperative pain, designed to be utilized in a hospital setting. The objective of the two studies was to determine if fentanyl ITS could be safely used with X-rays, computerized tomography (CT) scans and radiofrequency identification (RFID) devices. The ITS system has two components: controller and drug unit; the studies utilized ITS systems without fentanyl, referred to as the ITS Placebo system. The first study evaluated the effect of X-radiation on the operation of an ITS Placebo system. Five ITS Placebo systems were exposed to X-rays (20 and 200 mSv total radiation dose-the 200 mSv radiation dose represents a tenfold higher exposure than in clinical practice) while operating in the Ready Mode and five were exposed while operating in the Dose Mode. The second study evaluated the effect of RFID (worst-case scenario of direct contact with an RFID transmitter) on the operation of an ITS Placebo system. During these tests, observations of the user interface and measurements of output voltage confirmed proper function throughout all operational modes (Ready Mode, Dose Mode, End-of-Use Mode, and End-of-Life Mode). The ITS Placebo system met all specifications and no functional anomalies were observed during and following X-ray exposure at two radiation dose levels or exposure at six different combinations of RFID frequencies and field strengths. The performance of the ITS system was unaffected by X-ray exposure levels well beyond those associated with diagnostic X-rays and CT scans, and by exposure to radiofrequency field strengths typically generated by RFID devices. These results provide added confidence to clinicians that the fentanyl ITS system does not need to be removed during diagnostic X-rays and CT scans and can also be utilized in close proximity to RFID devices. The studies and writing of this manuscript were

  7. Diagnostic value of computerized tomography venography in detecting stenosis and occlusion of subclavian vein and superior vena in chronic renal failure patients.

    Science.gov (United States)

    Bakhshoude, Banafsheh; Ravari, Hassan; Kazemzadeh, Gholam Hosein; Rad, Masoud Pezeshki

    2016-08-01

    Currently, venography is the standard diagnostic method to examine veins before implementing access, which is invasive in nature. Computerized tomography venography (CTV) can simultaneously indicate deep and superficial venous systems in the upper extremity and their relation to the surrounding anatomical structures; however, its diagnostic value in the detection of central venous disease has yet to be defined. The aim of this study was to determine the diagnostic value of CT venography compared to venography in the diagnosis of stenosis and the occlusion of subclavian veins and the superior vena in renal failure patients. This cross-sectional study was conducted from January to September 2015 on patients with chronic renal failure undergoing upper extremity venography at the Radiology Department of Imam Reza Hospital in Mashhad, Iran. We excluded patients with catheters in their jugular and subclavian vein routes, venous hypertension with reverse-function fistula, or sensitivity to contrast agents. Several factors, including age, gender, catheterization record in jugular and subclavian veins, and fistula record in the upper extremity, as well as clinical symptoms consisting of edema, dermatitis, and ulcers in these organs, were recorded in the corresponding form. Then, the patients consecutively underwent indirect venography and CT venography and traces of stenosis (more than 50%) or complete occlusion in the subclavian vein and superior vena were recorded. The data were analyzed using SPSS software by the chi-squared test, and sensitivity, specificity, and positive and negative predictive values were calculated by means of MedCalc Online, version 16.2. The study was conducted on 40 patients (26 males and 14 females) with a mean age of 46.7 ± 10.4 years. In this study, 58 subclavian veins, as well as 32 superior vena cava, were studied. The results showed that the diagnostic value of CTV in the detection of subclavian stenosis had a sensitivity and a specificity

  8. High-resolution CT findings in Streptococcus milleri pulmonary infection.

    Science.gov (United States)

    Okada, F; Ono, A; Ando, Y; Nakayama, T; Ishii, H; Hiramatsu, K; Sato, H; Kira, A; Otabe, M; Mori, H

    2013-06-01

    To assess pulmonary high-resolution computed tomography (CT) findings in patients with acute Streptococcus milleri pulmonary infection. Sixty consecutive patients with acute S. milleri pneumonia who had undergone high-resolution CT chest examinations between January 2004 and March 2010 were retrospectively identified. Twenty-seven patients with concurrent infections were excluded. The final study group comprised 33 patients (25 men, 8 women; aged 20-88 years, mean 63.1 years) with S. milleri infection. The patients' clinical findings were assessed. Parenchymal abnormalities, enlarged lymph nodes, and pleural effusion were evaluated on high-resolution CT. Underlying conditions included malignancy (n = 15), a smoking habit (n = 11), and diabetes mellitus (n = 8). CT images of all patients showed abnormal findings, including ground-glass opacity (n = 24), bronchial wall thickening (n = 23), consolidation (n = 17), and cavities (n = 7). Pleural effusion was found in 18 patients, and complex pleural effusions were found in seven patients. Pulmonary infection caused by S. milleri was observed mostly in male patients with underlying conditions such as malignancy or a smoking habit. The CT findings in patients with S. milleri consisted mainly of ground-glass opacity, bronchial wall thickening, pleural effusions, and cavities. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Non-destructive analysis and detection of internal characteristics of spruce logs through X computerized tomography; Detection et analyse non destructive de caracteristiques internes de billons d'epicea commun (PICEA ABIES (L.) KARST) par tomographie a rayons X

    Energy Technology Data Exchange (ETDEWEB)

    Longuetaud, F

    2005-10-15

    Computerized tomography allows a direct access to internal features of scanned logs on the basis of density and moisture content variations. The objective of this work is to assess the feasibility of an automatic detection of internal characteristics with the final aim of conducting scientific analyses. The database is constituted by CT images of 24 spruces obtained with a medical CT scanner. Studied trees are representative of several social status and are coming from four stands located in North-Eastern France, themselves are representative of several age, density and fertility classes. The automatic processing developed are the following. First, pith detection in logs dealing with the problem of knot presence and ring eccentricity. The accuracy of the localisation was less than one mm. Secondly, the detection of the sapwood/heart-wood limit in logs dealing with the problem of knot presence (main source of difficulty). The error on the diameter was 1.8 mm which corresponds to a relative error of 1.3 per cent. Thirdly, the detection of the whorls location and comparison with an optical method. Fourthly the detection of individualized knots. This process allows to count knots and to locate them in a log (longitudinal position and azimuth); however, the validation of the method and extraction of branch diameter and inclination are still to be developed. An application of this work was a variability analysis of the sapwood content in the trunk: at the within-tree level, the sapwood width was found to be constant under the living crown; at the between-tree level, a strong correlation was found with the amount of living branches. A great number of analyses are possible from our work results, among others: architectural analysis with the pith tracking and the apex death occurrence; analysis of radial variations of the heart-wood shape; analysis of the knot distribution in logs. (author)

  10. High resolution computed tomography and pulmonary function tests ...

    African Journals Online (AJOL)

    Ehab

    assessed by pulmonary function tests (PFTs) namely spirometry and carbon monoxide diffusion capacity (DLCO) in .... separation of pulmonary parenchymal structures. Axial 1-2 mm thin sections were obtained every ..... the cellularity of lower respiratory tract as assessed by BAL, and the ground glass pattern of HRCT scan.

  11. COST EFFECTIVE AND HIGH RESOLUTION SUBSURFACE CHARACTERIZATION USING HYDRAULIC TOMOGRAPHY

    Science.gov (United States)

    2017-08-01

    K and Ss-values using analytical solutions based on the simplified assumption that the aquifer is homogeneous and uniform (e.g., Theis’ or Cooper...geostatistical model is referred to as the prior distribution model in a Bayesian statistical framework. HT analysis involves updating the statistical ...et al., 1996):        1 Tˆ ˆ ˆr r rc c c   Y Y ω d G Y (2-2) where r is the iteration index; G(·) indicates the nonlinear

  12. High resolution computed tomography and pulmonary function tests ...

    African Journals Online (AJOL)

    Background: Alveolar and airway injury represent one of the most common features of rheumatological diseases and is believed to have a significant impact on the course of these diseases. Objective: This work aimed at evaluating airway and alveolar involvement in children with systemic lupus erythematosus (SLE) and ...

  13. Complicações pulmonares após uso de crack: achados na tomografia computadorizada de alta resolução do tórax Pulmonary complications of crack cocaine use: high-resolution computed tomography of the chest

    Directory of Open Access Journals (Sweden)

    Alexandre Mançano

    2008-05-01

    Full Text Available Relatamos os achados na tomografia computadorizada de alta resolução de um paciente que, após uso de cocaína fumada (crack, desenvolveu quadro de hemoptise, dispnéia e dor torácica súbitas. As radiografias de tórax mostravam consolidações predominando em lobos superiores. A tomografia de alta resolução evidenciava opacidades em vidro fosco, consolidações e nódulos do espaço aéreo. Nova tomografia de controle, após suspensão da droga e uso de corticóides, mostrou regressão parcial das lesões e aparecimento de escavações. A correlação entre os achados clínicos, laboratoriais e de imagem permitiu o diagnóstico de "pulmão de crack".Here, we report high-resolution computed tomography (HRCT findings in a patient who developed sudden hemoptysis, dyspnea and chest pain after smoking crack cocaine. Chest X-rays showed consolidations, primarily in the upper lobes, and HRCT scans showed ground glass attenuation opacities, consolidations and air-space nodules. A follow-up CT, after drug use discontinuation and administration of corticosteroids, showed partial resolution of pulmonary lesions and the appearance of cavitations. Clinical, imaging and laboratory findings led to a diagnosis of 'crack lung'.

  14. Can carotid stenosis be operated without arteriography? Contribution of magnetic resonance and helical computerized tomography angiography; Peut-on operer une stenose carotidienne sans arteriographie? Apport de l`angioMR et/ou de l`angioscanner helicoidal

    Energy Technology Data Exchange (ETDEWEB)

    Auffrau-Calvier, E.; Kersaint-Gilly, A. de; Desal, H.A.; Viarouge, M.P.; Havet, T. [Hopital Laennec, 44 - Nantes (France)

    1996-09-01

    The aim of this work is to ascertain the role of the magnetic resonance angiography (MRA) and to compare it with the Doppler effect, the X-ray angiography and the new method of helical computerized tomography. Seventy one carotid bifurcations in 37 patients with suspected cerebral vascular events has been evaluated with the MRA and digitalized angiography, the reference method. The obtained data corroborate the good results proposed by other authors reporting in the literature and allow to propose this examination as a new means of investigating carotid bifurcations. Work with the helical computerized tomography appears to be promising too but there are few reported series. Therefore, there appears to be two interesting points: the reliability of distinguishing between very severe stenosis and occlusion, and the fine-tuned analysis of the plaque with detection of ulcerations. When a consistent approach is used to the evaluation of the carotid bifurcation, the Willis circle and the cerebral parenchyma, the MRA can complete the Doppler echo data and the preoperative arteriography can only be used in patients when the MRA and the Doppler echo results disagree. (authors)

  15. Qualitative interpretation of high resolution aeromagnetic (HRAM ...

    African Journals Online (AJOL)

    Qualitative interpretation of high resolution aeromagnetic (HRAM) data from some parts of offshore Niger delta, Nigeria. ... Open Access DOWNLOAD FULL TEXT ... The original raster map, obtained from the Nigeria Geological Survey Agency (NGSA) in half degree sheet, was subjected to qualitative data analysis using the ...

  16. A High-Resolution Stopwatch for Cents

    Science.gov (United States)

    Gingl, Z.; Kopasz, K.

    2011-01-01

    A very low-cost, easy-to-make stopwatch is presented to support various experiments in mechanics. The high-resolution stopwatch is based on two photodetectors connected directly to the microphone input of a sound card. Dedicated free open-source software has been developed and made available to download. The efficiency is demonstrated by a free…

  17. Compressive sensing for high resolution radar imaging

    NARCIS (Netherlands)

    Anitori, L.; Otten, M.P.G.; Hoogeboom, P.

    2010-01-01

    In this paper we present some preliminary results on the application of Compressive Sensing (CS) to high resolution radar imaging. CS is a recently developed theory which allows reconstruction of sparse signals with a number of measurements much lower than what is required by the Shannon sampling

  18. Compact high-resolution spectral phase shaper

    NARCIS (Netherlands)

    Postma, S.; van der Walle, P.; Offerhaus, Herman L.; van Hulst, N.F.

    2005-01-01

    The design and operation of a high-resolution spectral phase shaper with a footprint of only 7×10 cm2 is presented. The liquid-crystal modulator has 4096 elements. More than 600 independent degrees of freedom can be positioned with a relative accuracy of 1 pixel. The spectral shaping of pulses from

  19. High resolution analysis of interphase chromosome domains

    NARCIS (Netherlands)

    Visser, A. E.; Jaunin, F.; Fakan, S.; Aten, J. A.

    2000-01-01

    Chromosome territories need to be well defined at high resolution before functional aspects of chromosome organization in interphase can be explored. To visualize chromosomes by electron microscopy (EM), the DNA of Chinese hamster fibroblasts was labeled in vivo with thymidine analogue BrdU. Labeled

  20. Avaliação do ambiente solo-semente por meio da tomografia computadorizada Evaluation of the soil-seed environment through computerized tomography

    Directory of Open Access Journals (Sweden)

    Alcir José Modolo

    2008-04-01

    Full Text Available O condicionamento físico do solo ao redor das sementes reveste-se de grande importância para o bom desenvolvimento inicial da cultura, assegurando uma população sadia de plantas. O adequado contato solo-semente é um pré-requisito para a rápida emergência e o bom estabelecimento da cultura. Neste trabalho, objetivou-se utilizar a tomografia computadorizada de resolução milimétrica para determinação do ambiente solo-semente em sistema de plantio direto, logo após o plantio da cultura da soja. Utilizou-se o esquema de parcelas subdivididas, em que as parcelas constituíram-se de três teores de água do solo, correspondentes a 0,27; 0,31; e 0,36 kg kg-1, e as subparcelas de quatro níveis de carga, aplicadas pela roda compactadora, correspondentes a 0, 50, 90 e 140 N, no delineamento em blocos ao acaso, com quatro repetições. Foram avaliados a densidade média do solo na região da semente e o perfil de densidade média na linha de semeadura. De acordo com os resultados obtidos, pode-se concluir que as cargas aplicadas pela roda compactadora elevaram a densidade do solo no plano vertical da linha de semeadura abaixo da profundidade de semeadura, quando comparadas com as obtidas antes do plantio; a combinação entre cargas aplicadas pela roda compactadora e os teores de água no solo não influenciou a densidade média do solo na região da semente.The physical conditioning of the soil around seeds is of great importance for an adequate initial development of a crop, ensuring a healthy plant population. A suitable soil-seed contact is a prerequisite for a fast crop germination and good establishment. In this study, computerized tomography of millimeter resolution was used to determine the soil-seed environment in a no tillage system, immediately after soybean planting. A split plot design was used, in which the plots consisted of three contents of soil water, corresponding to 0.27; 0,31 and 0.36 kg kg-1, respectively, and the split

  1. High resolution technology for FPD lithography tools

    Science.gov (United States)

    Yabu, Nobuhiko; Nagai, Yoshiyuki; Tomura, Satoshi; Yoshikawa, Tomohiro

    2013-06-01

    As the resolution of LCD panels adapted for Smartphone and Tablet PC rapidly becomes higher, the performance needed for lithography tools to produce them also becomes higher than ever. To respond to such needs, we have developed new lithography tools for mass production of high resolution LCD panels. We have executed various exposure tests to evaluate their performance. In this paper, we present the results of these tests. By employing higher NA projection optics, high resolution (2.0μm and under) has been achieved. We also present the effect of special illumination and the difference in profile between kinds of photoresist. Furthermore, we also refer what will be needed for masks and blanks in the next generation. To achieve even higher resolution, it is necessary for masks and blanks to have high flatness, low level of defects and small linewidth error.

  2. Radiation length imaging with high resolution telescopes

    OpenAIRE

    Stolzenberg, U.; Frey, A.; Schwenker, B; Wieduwilt, P.; Marinas, C; Lütticke, F.

    2016-01-01

    The construction of low mass vertex detectors with a high level of system integration is of great interest for next generation collider experiments. Radiation length images with a sufficient spatial resolution can be used to measure and disentangle complex radiation length $X$/$X_0$ profiles and contribute to the understanding of vertex detector systems. Test beam experiments with multi GeV particle beams and high-resolution tracking telescopes provide an opportunity to obtain precise 2D imag...

  3. High Resolution Spectra of HE Detonations

    Science.gov (United States)

    1980-07-07

    region. We shall assume for present purposes that the emissivity of the detonation products of a 50 to 100 lb HE explosion is also in the viciity of... speed . Incorporated in the emulsion layers are dye forming coup- lers which react simultaneously during I , developmentto produce a separate dye S...Best Available Cop 1~EV~ AFTAC-TR-80-24 HIGH RESOLUTION SPECTRA OF HE DETONATIONS HSS Inc 2 Alfred Circle Bedford, MA 01730 7 JULY 1980 AUG 4 9D

  4. High resolution NMR theory and chemical applications

    CERN Document Server

    Becker, Edwin D

    1969-01-01

    High Resolution NMR: Theory and Chemical Applications focuses on the applications of nuclear magnetic resonance (NMR), as well as chemical shifts, lattices, and couplings. The book first offers information on the theory of NMR, including nuclear spin and magnetic moment, spin lattice relaxation, line widths, saturation, quantum mechanical description of NMR, and ringing. The text then ponders on instrumentation and techniques and chemical shifts. Discussions focus on the origin of chemical shifts, reference compounds, empirical correlations of chemical shifts, modulation and phase detection,

  5. Image derived input functions for dynamic High Resolution Research Tomograph PET brain studies

    NARCIS (Netherlands)

    Mourik, J.E.M.; van Velden, F.H.P.; Lubberink, J.M.; Kloet, R.W.; van Berckel, B.N.M.; Lammertsma, A.A.; Boellaard, R.

    2008-01-01

    The High Resolution Research Tomograph (HRRT) is a dedicated human brain positron emission tomography (PET) scanner. The aim of the present study was to validate the use of image derived input functions (IDIF) as an alternative for arterial sampling for HRRT human brain studies. To this end, IDIFs

  6. Pneumonia eosinofílica crônica secundária ao uso prolongado de nitrofurantoína: achados da tomografia computadorizada de alta resolução do tórax Chronic eosinophilic pneumonia secondary to long-term use of nitrofurantoin: high-resolution computed tomography findings

    Directory of Open Access Journals (Sweden)

    Rosane Rodrigues Martins

    2008-03-01

    Full Text Available Os autores relatam o caso de uma paciente com estenose de uretra que desenvolveu pneumonia eosinofílica crônica secundária ao uso prolongado de nitrofurantoína como profilaxia para infecção urinária de repetição. A paciente havia sido submetida a uma biópsia pulmonar a céu aberto. É dada ênfase aos achados da tomografia computadorizada de alta resolução do tórax, já que, embora as alterações pulmonares associadas à toxicidade da nitrofurantoína geralmente sejam basais e bilaterais, no caso aqui descrito, as lesões de natureza interstício-alveolares situaram-se nas regiões subpleurais dos lobos superiores. Esses achados, por si só, são muito sugestivos de pneumonia eosinofílica crônica. O diagnóstico foi confirmado por meio da revisão da biópsia.The authors report the case of a female patient who developed chronic eosinophilic pneumonia secondary to long-term use of nitrofurantoin for prophylaxis of recurrent urinary tract infections due to urethral stenosis. On high-resolution computed tomography scans, the pulmonary reaction to nitrofurantoin most commonly manifests as an interstitial-alveolar pattern in both lung bases. However, in this case, the alterations were most pronounced in the periphery of the upper lobes. In itself, this tomographic profile is strongly indicative of chronic eosinophilic pneumonia. The patient had previously been submitted to an open lung biopsy. The diagnosis of chronic eosinophilic pneumonia was confirmed through a review of the biopsy.

  7. MODERN BEAMS FOR ANCIENT MUMMIES COMPUTERIZED TOMOGRAPHY OF THE HOLOCENE MUMMIFIED REMAINS FROM WADI TAKARKORI (ACACUS, SOUTH-WESTERN LIBYA; MIDDLE PASTORAL).

    Science.gov (United States)

    Di Vincenzo, Fabio; Carbone, Iacopo; Ottini, Laura; Profico, Antonio; Ricci, Francesca; Tafuri, Mary Anne; Fornaciari, Gino; Manzi, Giorgio

    2015-01-01

    The Middle Pastoral human remains from Wadi Takarkori in the Libyan Acacus mountains (Fezzan) are exceptionally preserved partial mummies ranging between 6100 and 5000 uncal years BP; this small sample represents the most ancient of its kind ever found. In this report, we present a survey of the skeletal anatomy of these mummifed corpses, based on high resolution CT-scan data, including a preliminary phenetic interpretation of their cranial morphology.

  8. Segmentation of Striatal Brain Structures from High Resolution PET Images

    Directory of Open Access Journals (Sweden)

    Ricardo J. P. C. Farinha

    2009-01-01

    Full Text Available We propose and evaluate an automatic segmentation method for extracting striatal brain structures (caudate, putamen, and ventral striatum from parametric C11-raclopride positron emission tomography (PET brain images. We focus on the images acquired using a novel brain dedicated high-resolution (HRRT PET scanner. The segmentation method first extracts the striatum using a deformable surface model and then divides the striatum into its substructures based on a graph partitioning algorithm. The weighted kernel k-means algorithm is used to partition the graph describing the voxel affinities within the striatum into the desired number of clusters. The method was experimentally validated with synthetic and real image data. The experiments showed that our method was able to automatically extract caudate, ventral striatum, and putamen from the images. Moreover, the putamen could be subdivided into anterior and posterior parts. An automatic method for the extraction of striatal structures from high-resolution PET images allows for inexpensive and reproducible extraction of the quantitative information from these images necessary in brain research and drug development.

  9. High-Resolution Characterization of UMo Alloy Microstructure

    Energy Technology Data Exchange (ETDEWEB)

    Devaraj, Arun [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kovarik, Libor [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Joshi, Vineet V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jana, Saumyadeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Manandhar, Sandeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Arey, Bruce W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-30

    This report highlights the capabilities and procedure for high-resolution characterization of UMo fuels in PNNL. Uranium-molybdenum (UMo) fuel processing steps, from casting to forming final fuel, directly affect the microstructure of the fuel, which in turn dictates the in-reactor performance of the fuel under irradiation. In order to understand the influence of processing on UMo microstructure, microstructure characterization techniques are necessary. Higher-resolution characterization techniques like transmission electron microscopy (TEM) and atom probe tomography (APT) are needed to interrogate the details of the microstructure. The findings from TEM and APT are also directly beneficial for developing predictive multiscale modeling tools that can predict the microstructure as a function of process parameters. This report provides background on focused-ion-beam–based TEM and APT sample preparation, TEM and APT analysis procedures, and the unique information achievable through such advanced characterization capabilities for UMo fuels, from a fuel fabrication capability viewpoint.

  10. High-resolution ZTE imaging of human teeth.

    Science.gov (United States)

    Weiger, Markus; Pruessmann, Klaas P; Bracher, Anna-Katinka; Köhler, Sascha; Lehmann, Volker; Wolfram, Uwe; Hennel, Franciszek; Rasche, Volker

    2012-10-01

    MRI with zero echo time (ZTE) is achieved by 3D radial centre-out encoding and hard-pulse RF excitation while the projection gradient is already on. Targeting short-T(2) samples, the efficient, robust and silent ZTE approach was implemented for high-bandwidth high-resolution imaging requiring particularly rapid transmit-receive switching and algebraic image reconstruction. The ZTE technique was applied to image extracted human teeth at 11.7T field strength, yielding detailed depictions with very good delineation of the mineralised dentine and enamel layers. ZTE results are compared with UTE (ultra-short echo time) MRI and micro-computed tomography (μCT), revealing significant differences in SNR and CNR yields. Compared to μCT, ZTE MRI appears to be less susceptible to artefacts caused by dental fillings and to offer superior sensitivity for the detection of early demineralisation and caries lesions. Copyright © 2012 John Wiley & Sons, Ltd.

  11. High resolution X-ray CT for advanced electronics packaging

    Science.gov (United States)

    Oppermann, M.; Zerna, T.

    2017-02-01

    Advanced electronics packaging is a challenge for non-destructive Testing (NDT). More, smaller and mostly hidden interconnects dominate modern electronics components and systems. To solve the demands of customers to get products with a high functionality by low volume, weight and price (e.g. mobile phones, personal medical monitoring systems) often the designers use System-in-Package solutions (SiP). The non-destructive testing of such devices is a big challenge. So our paper will impart fundamentals and applications for non-destructive evaluation of inner structures of electronics packaging for quality assurance and reliability investigations with a focus on X-ray methods, especially on high resolution X-ray computed tomography (CT).

  12. Proposal for dose measurement in the crystalline lens and thyroid in computerized tomography of paranasal sinuses; Proposta de medicao de dose no cristalino e na tireoide em exame de tomografia de seios da face

    Energy Technology Data Exchange (ETDEWEB)

    Mello, Ana Caroline; Machado Neto, Vicente, E-mail: ana.caroline91@hotmail.com [Universidade Tecnologica Federal do Parana (UTFPR/PPGEB), Curitiba, PR (Brazil). Programa de Pos Graduacao em Engenharia Biomedica

    2014-07-01

    With the evolution of diagnostic imaging equipment, a computerized tomography (CT) has become one of the most used tests to assess pathologies affecting the paranasal sinuses. This work aims at presenting a method of obtaining measurements of dose in the eye lenses and thyroid, from the execution of CT of the paranasal sinuses protocol. Experimental procedure will be used in an object simulator (phantom) head and neck made with accessible materials and thermoluminescent dosimeters (TLDs) of LiF: Mg,Ti for the absorbed dose in the regions of interest, when exposed to radiation in a CT scanner 16 channels. After the dosimetric evaluation with phantom use, this methodology will be applied in vivo, or in patients with medical request for the examination and approval by the Ethics Committee. Thus, at the end of this survey protocols and actions aimed at reducing the absorbed dose in the eye lenses and thyroid without impairing the diagnostic image quality can be proposed. (author)

  13. Volumetric evaluation of coronary plaque in patients presenting with acute myocardial infarction or stable angina pectoris-a multislice computerized tomography study

    DEFF Research Database (Denmark)

    Hammer-Hansen, Sophia; Kofoed, Klaus Fuglsang; Kelbaek, Henning

    2009-01-01

    BACKGROUND: We hypothesized that unstable clinical presentation of coronary artery disease is associated with distinct characteristics of culprit lesions identifiable by multislice computed tomography (MSCT). METHODS: Patients with non-ST-elevation myocardial infarction (NSTEMI) (n = 57) or stable...

  14. Ultra-high resolution coded wavefront sensor

    KAUST Repository

    Wang, Congli

    2017-06-08

    Wavefront sensors and more general phase retrieval methods have recently attracted a lot of attention in a host of application domains, ranging from astronomy to scientific imaging and microscopy. In this paper, we introduce a new class of sensor, the Coded Wavefront Sensor, which provides high spatio-temporal resolution using a simple masked sensor under white light illumination. Specifically, we demonstrate megapixel spatial resolution and phase accuracy better than 0.1 wavelengths at reconstruction rates of 50 Hz or more, thus opening up many new applications from high-resolution adaptive optics to real-time phase retrieval in microscopy.

  15. High resolution extremity CT for biomechanics modeling

    Energy Technology Data Exchange (ETDEWEB)

    Ashby, A.E.; Brand, H.; Hollerbach, K.; Logan, C.M.; Martz, H.E.

    1995-09-23

    With the advent of ever more powerful computing and finite element analysis (FEA) capabilities, the bone and joint geometry detail available from either commercial surface definitions or from medical CT scans is inadequate. For dynamic FEA modeling of joints, precise articular contours are necessary to get appropriate contact definition. In this project, a fresh cadaver extremity was suspended in parafin in a lucite cylinder and then scanned with an industrial CT system to generate a high resolution data set for use in biomechanics modeling.

  16. Detailed mitochondrial phenotyping by high resolution metabolomics.

    Directory of Open Access Journals (Sweden)

    James R Roede

    Full Text Available Mitochondrial phenotype is complex and difficult to define at the level of individual cell types. Newer metabolic profiling methods provide information on dozens of metabolic pathways from a relatively small sample. This pilot study used "top-down" metabolic profiling to determine the spectrum of metabolites present in liver mitochondria. High resolution mass spectral analyses and multivariate statistical tests provided global metabolic information about mitochondria and showed that liver mitochondria possess a significant phenotype based on gender and genotype. The data also show that mitochondria contain a large number of unidentified chemicals.

  17. A Portable, High Resolution, Surface Measurement Device

    Science.gov (United States)

    Ihlefeld, Curtis M.; Burns, Bradley M.; Youngquist, Robert C.

    2012-01-01

    A high resolution, portable, surface measurement device has been demonstrated to provide micron-resolution topographical plots. This device was specifically developed to allow in-situ measurements of defects on the Space Shuttle Orbiter windows, but is versatile enough to be used on a wide variety of surfaces. This paper discusses the choice of an optical sensor and then the decisions required to convert a lab bench optical measurement device into an ergonomic portable system. The necessary trade-offs between performance and portability are presented along with a description of the device developed to measure Orbiter window defects.

  18. Determination of the dose index in computerized tomography using thermoluminescent dosemeters; Determinacion del indice de dosis en tomografia computada usando dosimetros termoluminiscentes

    Energy Technology Data Exchange (ETDEWEB)

    Azorin, J.C.; Calderon, A. [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada-IPN, 11500 Mexico D.F. (Mexico); Azorin, J. [UAM-I, 09340 Mexico D.F. (Mexico)

    2004-07-01

    In this work the obtained results of the determination of the dose index are presented in thorax studies in computed tomography and helical tomography carried out in Mexico using thermoluminescent dosemeters of LiF: Mg,Cu,P + Ptfe developed and manufactured in our country. The results showed that under similar conditions of irradiation and operation (pitch = 1), significant differences don't exist among the doses absorbed measures in the phantom due to the two types of used tomographs. (Author)

  19. High-Resolution PET Detector. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Karp, Joel

    2014-03-26

    The objective of this project was to develop an understanding of the limits of performance for a high resolution PET detector using an approach based on continuous scintillation crystals rather than pixelated crystals. The overall goal was to design a high-resolution detector, which requires both high spatial resolution and high sensitivity for 511 keV gammas. Continuous scintillation detectors (Anger cameras) have been used extensively for both single-photon and PET scanners, however, these instruments were based on NaI(Tl) scintillators using relatively large, individual photo-multipliers. In this project we investigated the potential of this type of detector technology to achieve higher spatial resolution through the use of improved scintillator materials and photo-sensors, and modification of the detector surface to optimize the light response function.We achieved an average spatial resolution of 3-mm for a 25-mm thick, LYSO continuous detector using a maximum likelihood position algorithm and shallow slots cut into the entrance surface.

  20. Principles of high resolution NMR in solids

    CERN Document Server

    Mehring, Michael

    1983-01-01

    The field of Nuclear Magnetic Resonance (NMR) has developed at a fascinating pace during the last decade. It always has been an extremely valuable tool to the organic chemist by supplying molecular "finger print" spectra at the atomic level. Unfortunately the high resolution achievable in liquid solutions could not be obtained in solids and physicists and physical chemists had to live with unresolved lines open to a wealth of curve fitting procedures and a vast amount of speculations. High resolution NMR in solids seemed to be a paradoxon. Broad structure­ less lines are usually encountered when dealing with NMR in solids. Only with the recent advent of mUltiple pulse, magic angle, cross-polarization, two-dimen­ sional and multiple-quantum spectroscopy and other techniques during the last decade it became possible to resolve finer details of nuclear spin interactions in solids. I have felt that graduate students, researchers and others beginning to get involved with these techniques needed a book which trea...

  1. High-Resolution Scintimammography: A Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Rachel F. Brem; Joelle M. Schoonjans; Douglas A. Kieper; Stan Majewski; Steven Goodman; Cahid Civelek

    2002-07-01

    This study evaluated a novel high-resolution breast-specific gamma camera (HRBGC) for the detection of suggestive breast lesions. Methods: Fifty patients (with 58 breast lesions) for whom a scintimammogram was clinically indicated were prospectively evaluated with a general-purpose gamma camera and a novel HRBGC prototype. The results of conventional and high-resolution nuclear studies were prospectively classified as negative (normal or benign) or positive (suggestive or malignant) by 2 radiologists who were unaware of the mammographic and histologic results. All of the included lesions were confirmed by pathology. Results: There were 30 benign and 28 malignant lesions. The sensitivity for detection of breast cancer was 64.3% (18/28) with the conventional camera and 78.6% (22/28) with the HRBGC. The specificity with both systems was 93.3% (28/30). For the 18 nonpalpable lesions, sensitivity was 55.5% (10/18) and 72.2% (13/18) with the general-purpose camera and the HRBGC, respectively. For lesions 1 cm, 7 of 15 were detected with the general-purpose camera and 10 of 15 with the HRBGC. Four lesions (median size, 8.5 mm) were detected only with the HRBGC and were missed by the conventional camera. Conclusion: Evaluation of indeterminate breast lesions with an HRBGC results in improved sensitivity for the detection of cancer, with greater improvement shown for nonpalpable and 1-cm lesions.